WorldWideScience

Sample records for generator overtopping performance

  1. Sea Slot Cone Generator Overtopping Performance in 3D Conditions

    DEFF Research Database (Denmark)

    Margheritini, Lucia; Vicinanza, Diego; Frigaard, Peter

    2008-01-01

    This note describes the influence of wave spreading, directionality and local bathymetry on the efficiency of the SSG wave energy converter Pilot plant in Kvitsøy, Norway. This is an overtopping device i.e. its efficiency is directly proportional to the overtopping flows in the three reservoirs t...... is also described. It has been found that the performance of the SSG Pilot will be negatively affected by spreading and directionality of the incoming waves as direct consequence of reduction on the overtopping flow rates of 10% - 35% compared to 2D conditions....

  2. Crest Level Optimization of the Multi Level Overtopping based Wave Energy Converter Seawave Slot-Cone Generator

    DEFF Research Database (Denmark)

    Kofoed, Jens Peter; Osaland, E.

    2005-01-01

    The paper describes the optimization of the crest levels and geometrical layout of the SSG structure, focusing on maximizing the obtained potential energy in the overtopping water. During wave tank testing at AAU average overtopping rates into the individual reservoirs have been measured. The ini......The paper describes the optimization of the crest levels and geometrical layout of the SSG structure, focusing on maximizing the obtained potential energy in the overtopping water. During wave tank testing at AAU average overtopping rates into the individual reservoirs have been measured....... The initial tests led to an expression describing the derivative of the overtopping rate with respect to the vertical distance. Based on this, numerical optimizations of the crest levels, for a number of combinations of wave conditions, have been performed. The hereby found optimal crest levels have been...

  3. Design, Construction, Reliability and Hydraulic Performance of an Innovative Wave Overtopping Device

    DEFF Research Database (Denmark)

    Frigaard, Peter; Andersen, Thomas Lykke; Margheritini, Lucia

    2008-01-01

    The SSG (Sea Slot-cone Generator) is a wave energy converter of the overtopping type. The structure consists of a number of reservoirs one on the top of each others above the mean water level, in which the water of incoming waves is stored temporary. In each reservoir, expressively designed low h...

  4. Hydraulic Performance of an Innovative Breakwater for Overtopping Wave Energy Conversion

    Directory of Open Access Journals (Sweden)

    Claudio Iuppa

    2016-11-01

    Full Text Available The Overtopping BReakwaterfor Energy Conversion (OBREC is an overtopping wave energy converter, totally embedded in traditional rubble mound breakwaters. The device consists of a reinforced concrete front reservoir designed with the aim of capturing the wave overtopping in order to produce electricity. The energy is extracted through low head turbines, using the difference between the water levels in the reservoir and the sea water level. This paper analyzes the OBREC hydraulic performances based on physical 2D model tests carried out at Aalborg University (DK. The analysis of the results has led to an improvement in the overall knowledge of the device behavior, completing the main observations from the complementary tests campaign carried out in 2012 in the same wave flume. New prediction formula are presented for wave reflection, the overtopping rate inside the front reservoir and at the rear side of the structure. Such methods have been used to design the first OBREC prototype breakwater in operation since January 2016 at Naples Harbor (Italy.

  5. On the Effects of Geometry Control on the Performance of Overtopping Wave Energy Converters

    DEFF Research Database (Denmark)

    Victor, Lander; Troch, Peter; Kofoed, Jens Peter

    2011-01-01

    Overtopping wave energy converters (OWECs) are designed to extract energy from ocean waves based on wave overtopping into a reservoir, which is emptied into the ocean through a set of low-head turbines, and typically feature a low crest freeboard and a smooth impermeable steep slope. In the process...... of optimizing the performance of OWECs, the question arises whether adapting the slope geometry to the variable wave characteristics at the deployment site (i.e., geometry control) can increase the overall hydraulic efficiency and overall hydraulic power compared to a fixed slope geometry. The effect of five...... different geometry control scenarios on the overall hydraulic efficiency and overall hydraulic power of OWECs has been simulated for three possible deployment sites using empirical prediction formulae. The results show that the effect of an adaptive slope angle is relatively small. On the other hand...

  6. SSG wave energy converter. Design, reliability and hydraulic performance of an innovative overtopping device

    Energy Technology Data Exchange (ETDEWEB)

    Margheritini, L.; Frigaard, P. [Department of Civil Engineering, Aalborg University. Sohngaardsholmsvej 57, DK-9000 Aalborg (Denmark); Vicinanza, D. [Department of Civil Engineering - CIRIAM, Seconda Universita di Napoli. Via Roma 29, 81031 Aversa (Caserta) (Italy)

    2009-05-15

    The SSG (Sea Slot-cone Generator) is a wave energy converter of the overtopping type. The structure consists of a number of reservoirs one on the top of each other above the mean water level in which the water of incoming waves is stored temporary. In each reservoir, expressively designed low head hydro-turbines are converting the potential energy of the stored water into power. A key to success for the SSG will be the low cost of the structure and its robustness. The construction of the pilot plant is scheduled and this paper aims to describe the concept of the SSG wave energy converter and the studies behind the process that leads to its construction. The pilot plant is an on-shore full-scale module in 3 levels with an expected power production of 320 MWh/y in the North Sea. Location, wave climate and laboratory tests' results will be used here to describe the pilot plant and its characteristics. (author)

  7. Marine Structures with Extreme Overtopping Rates

    DEFF Research Database (Denmark)

    Kofoed, Jens Peter; Frigaard, Peter

    2000-01-01

    In design of sea defence structures like seawalls, breakwaters and dikes, one of the main objectives is to minimize or even eliminate wave overtopping. For this reason numerous investigations have been performed over the past many years to determine the amount of overtopping occurring for typical...

  8. R&D Towards Commercialization of Sea Wave Slot Cone Generator (SSG) Overtopping Wave Energy Converter

    DEFF Research Database (Denmark)

    Margheritini, Lucia

    between ventures and private investors, and to promote an accelerated shift from a technology to a market focus. This Thesis is presented as a collection of works published by the author on her research on the Sea wave Slot cone Generator wave energy converter. These include 1 accepted and 2 submitted......Global energy needs are likely to continue to grow steadily for the next two and a half decades (International Energy Agency, 2006). If governments continue with current policies the world’s energy needs would be more than 50% higher in 2030 than today. Over 60% of that increase would be covered...... in the form of oil and natural gas. Climate destabilizing carbon-dioxide emissions would continue to rise, calling into question the long-term sustainability of the global energy system. More vigorous government policies in consuming countries are steering the world onto an energy path oriented to reduce...

  9. Simulation of Wave Overtopping of Maritime Structures in a Numerical Wave Flume

    Directory of Open Access Journals (Sweden)

    Tiago C. A. Oliveira

    2012-01-01

    Full Text Available A numerical wave flume based on the particle finite element method (PFEM is applied to simulate wave overtopping for impermeable maritime structures. An assessment of the performance and robustness of the numerical wave flume is carried out for two different cases comparing numerical results with experimental data. In the first case, a well-defined benchmark test of a simple low-crested structure overtopped by regular nonbreaking waves is presented, tested in the lab, and simulated in the numerical wave flume. In the second case, state-of-the-art physical experiments of a trapezoidal structure placed on a sloping beach overtopped by regular breaking waves are simulated in the numerical wave flume. For both cases, main overtopping events are well detected by the numerical wave flume. However, nonlinear processes controlling the tests proposed, such as nonlinear wave generation, energy losses along the wave propagation track, wave reflection, and overtopping events, are reproduced with more accuracy in the first case. Results indicate that a numerical wave flume based on the PFEM can be applied as an efficient tool to supplement physical models, semiempirical formulations, and other numerical techniques to deal with overtopping of maritime structures.

  10. Comparison Between Overtopping Discharge in Small and Large Scale Models

    DEFF Research Database (Denmark)

    Helgason, Einar; Burcharth, Hans F.

    2006-01-01

    The present paper presents overtopping measurements from small scale model test performed at the Haudraulic & Coastal Engineering Laboratory, Aalborg University, Denmark and large scale model tests performed at the Largde Wave Channel,Hannover, Germany. Comparison between results obtained from...... small and large scale model tests show no clear evidence of scale effects for overtopping above a threshold value. In the large scale model no overtopping was measured for waveheights below Hs = 0.5m as the water sunk into the voids between the stones on the crest. For low overtopping scale effects...

  11. Wave Overtopping of Marine Structures

    DEFF Research Database (Denmark)

    Kofoed, Jens Peter

    During the past 50 years tools for predicting wave overtopping of sea defense structures have continuously been refined. However, developers of wave energy converters have raised questions about how to predict the overtopping of structures with layouts significantly different from those of sea...... to a wide range of sea states. Overtopping slope layouts resulting in substantial energy content in the overtopping discharges have been pointed out. The influence of various geometrical parameters, such as slope shape, shape of guiding walls, draft and crest freeboard, on the overtopping discharges has...... been investigated. The effect of using overtopping reservoirs at multiple levels has also been quantified. The emphasis is generally on optimizing the overtopping with respect to maximizing the potential energy in the overtopping water. Based on the experimental data expressions for predicting wave...

  12. Seawall Overtopping Tests

    DEFF Research Database (Denmark)

    Frigaard, Peter

    At the request of Mr. J. Bulow Beck, Havnecon A/S the Hydraulics Laboratory at University of Aalborg, Denmark carried out model test with the objective of studying the overtopping of a seawall designed for the protection of a new road and promenade, the SOHAR CORNICE, in the Sultanate of Oman...

  13. Estimation of Overtopping Rates on Slopes in Wave Power Devices and Other Low Crested Structures

    DEFF Research Database (Denmark)

    Kofoed, Jens Peter; Burcharth, Hans Falk

    2002-01-01

    Motivated by questions raised by developers of wave energy devices based on wave overtopping concepts, model tests have been performed to study overtopping of structures with limited draught, low crest freeboards and slope geometries designed to increase overtopping and thereby also the captured...

  14. Wave Overtopping at Coastal Structures

    DEFF Research Database (Denmark)

    Geeraearts, Jimmy; De Rouck, Julien; Troch, Peter

    2006-01-01

    The European research project CLASH (EVK3-CT-2001-00058) investigated wave overtopping at coastal structures. More specific it was to develop a generic prediction method for wave overtopping and to solve the problem of suspected scale effects. The paper summarizes the main results concerning...

  15. A Critical Analysis and Validation of the Accuracy of Wave Overtopping Prediction Formulae for OWECs

    Directory of Open Access Journals (Sweden)

    David Gallach-Sánchez

    2018-01-01

    Full Text Available The development of wave energy devices is growing in recent years. One type of device is the overtopping wave energy converter (OWEC, for which the knowledge of the wave overtopping rates is a basic and crucial aspect in their design. In particular, the most interesting range to study is for OWECs with steep slopes to vertical walls, and with very small freeboards and zero freeboards where the overtopping rate is maximized, and which can be generalized as steep low-crested structures. Recently, wave overtopping prediction formulae have been published for this type of structures, although their accuracy has not been fully assessed, as the overtopping data available in this range is scarce. We performed a critical analysis of the overtopping prediction formulae for steep low-crested structures and the validation of the accuracy of these formulae, based on new overtopping data for steep low-crested structures obtained at Ghent University. This paper summarizes the existing knowledge about average wave overtopping, describes the physical model tests performed, analyses the results and compares them to existing prediction formulae. The new dataset extends the wave overtopping data towards vertical walls and zero freeboard structures. In general, the new dataset validated the more recent overtopping formulae focused on steep slopes with small freeboards, although the formulae are underpredicting the average overtopping rates for very small and zero relative crest freeboards.

  16. Marine Structures with Heavy Overtopping

    DEFF Research Database (Denmark)

    Kofoed, Jens Peter; Frigaard, Peter

    2000-01-01

    An investigation of wave overtopping of marine structures is described. Focus is put on structures with realtively low crest levels and various slope layouts subjected to non-breaking waves. Influence of slope draught and angle is investigated....

  17. Risk analysis for earth dam overtopping

    Directory of Open Access Journals (Sweden)

    Mo Chongxun

    2008-06-01

    Full Text Available In this paper, a model of overtopping risk under the joint effects of floods and wind waves, which is based on risk analysis theory and takes into account the uncertainties of floods, wind waves, reservoir capacity and discharge capacity of the spillway, is proposed and applied to the Chengbihe Reservoir in Baise City in Guangxi Zhuang Autonomous Region. The simulated results indicate that the flood control limiting level can be raised by 0.40 m under the condition that the reservoir overtopping risk is controlled within a mean variance of 5×10−6. As a result, the reservoir storage will increase to 16 million m3 and electrical energy generation and other functions of the reservoir will also increase greatly.

  18. Wave Overtopping Characteristics of the Wave Dragon

    DEFF Research Database (Denmark)

    Tedd, James; Kofoed, Jens Peter

    Simulation work has been used extensively with the Wave dragon and other overtopping devices to analyse the power production performance of them and to optimise the structural design and the control strategy. A time domain approach to this is well documented in Jakobsen & Frigaard 1999. Using...... measurements taken from the Wave Dragon Nissum Bredning prototype, some of the previous assumptions have been slightly modified and improved upon, so that the simulation method better represents the reality of what is occurring....

  19. Overtopping of Berm Breakwaters Extension of Overtopping Formula

    DEFF Research Database (Denmark)

    Andersen, Thomas Lykke; Burcharth, H. F.

    2005-01-01

    the formula is improved so it gives reliable estimates also for more stable structures. The extension of the overtopping formula is based on analysis of front slope stability data from many different data sets. In most cases there is only a small difference between the Lykke Andersen & Burcharth (2004......In this paper is presented an improved version of the overtopping formula by Lykke Andersen & Burcharth (2004)valid for berm breakwaters with initial slopes of 1:1.25. In the present paper guidelines is given on how to modify the formula to take into account the initial slope angle. Further...

  20. Overtopping and Rear Slope Stability of Reshaping & Non-reshaping Berm Breakwaters

    DEFF Research Database (Denmark)

    Andersen, Thomas Lykke; Burcharth, H. F.

    2004-01-01

    Overtopping and rear slope stability of reshaping and non-reshaping berm breakwaters have been studied in a wave flume. A total of 695 tests have been performed to cover the influence of crest freeboard, crest width, berm width, berm elevation, stone size and sea state. Formula for average...... overtopping discharge that includes these parameters has been derived. The measurements show good correlation between average overtopping discharge and rear slope damage....

  1. Turbine Control Strategy using Wave Prediction to Optimise Power Take Off of Overtopping Wave Energy Converters

    DEFF Research Database (Denmark)

    Tedd, James; Knapp, Wilfried; Frigaard, Peter

    2005-01-01

    This paper presents the control strategy used on Wave Dragon overtopping wave energy converter. The nature of overtopping requires that for optimum performance the water level in the reservoir must be controlled by controlling the turbine outflows. A history of the simulations performed is included...

  2. Experimental Study of a Multi Level Overtopping Wave Power Device

    DEFF Research Database (Denmark)

    Kofoed, Jens Peter; Hald, Tue; Frigaard, Peter Bak

    2002-01-01

    Results of experimental investigations of a floating wave energy device called Power Pyramid is presented. The Power Pyramid utilizes reservoirs in multiple levels when capturing wave overtopping and converting it into electrical energy. The effect of capturing the overtopping in multiple levels,......, using 5 levels introduces practical problems, and is most probably not economically feasible. It is concluded that it is reasonable to use 2 levels (maybe 3), which can increase the efficiency by 25-40 % compared to using a single level.......Results of experimental investigations of a floating wave energy device called Power Pyramid is presented. The Power Pyramid utilizes reservoirs in multiple levels when capturing wave overtopping and converting it into electrical energy. The effect of capturing the overtopping in multiple levels......, compared to only one level, has been evaluated experimentally. From the experimental results, and the performed optimizations based on these, it has been found that the efficiency of a wave power device of the overtopping type can be increased by as much as 76 % by using 5 levels instead of 1. However...

  3. COMPARISON OF NUMERICAL AND EXPERIMENTAL RESULTS FOR OVERTOPPING DISCHARGE OF THE OBREC WAVE ENERGY CONVERTER

    Directory of Open Access Journals (Sweden)

    A. YAZID MALIKI

    2017-05-01

    Full Text Available OBREC is the latest innovation of overtopping wave energy converter (WEC which is coalesced with the rubble mound breakwaters. The acquisition of wave overtopping in a front reservoir and consequently releasing process through turbine is the concept of energy production in OBREC. The physical scale model studies of overtopping discharge of the OBREC have recently been done by previous researcher in wave flume at Aalborg University. This paper demonstrates the overtopping behavior of OBREC device using a VOF method with capabilities to solve RANS equation in the numerical suite Flow3D. The purpose of this research is to validate the overtopping discharge performance of the numerical model against the experiments of the OBREC. Based on the observation, the results have shown a good agreement between the validation and physical experiment.

  4. Experimental Update of the Overtopping Model Used for the Wave Dragon Wave Energy Converter

    DEFF Research Database (Denmark)

    Parmeggiani, Stefano; Kofoed, Jens Peter; Friis-Madsen, Erik

    2013-01-01

    An overtopping model specifically suited for Wave Dragon is needed in order to improve the reliability of its performance estimates. The model shall be comprehensive of all relevant physical processes that affect overtopping and flexible to adapt to any local conditions and device configuration....... An experimental investigation is carried out to update an existing formulation suited for 2D draft-limited, low-crested structures, in order to include the effects on the overtopping flow of the wave steepness, the 3D geometry of Wave Dragon, the wing reflectors, the device motions and the non-rigid connection...... of which can be measured in real-time. Instead of using new fitting coefficients, this approach allows a broader applicability of the model beyond the Wave Dragon case, to any overtopping WEC or structure within the range of tested conditions. Predictions reliability of overtopping over Wave Dragon...

  5. Optimization of Overtopping Wave Energy Converters by Geometry Control

    DEFF Research Database (Denmark)

    Victor, L.; Troch, P.; Kofoed, Jens Peter

    2011-01-01

    In this paper, the results of a study on the effects of geometry control on the performance of overtopping wave energy converters with a simple geometry built in coastal structures (simple OWECs) are presented. Empirical formulae, derived based on experimental tests on simple OWECs with varying...

  6. Wave overtopping erosion tests at Groningen sea dyke

    NARCIS (Netherlands)

    Verhagen, H.J.; Akkerman, G.J.; van Gerven, K.A.J.; Schaap, H.A.; van der Meer, J.W.

    2007-01-01

    In the present report field erosion tests of the inner slope of a sea dyke in the province of Groningen (near Delfzijl) are described for the situation of severe wave overtopping. Three types of tests have been performed: tests at the present grass cover, tests at a reinforced grass cover and tests

  7. Experimental Modeling of the Overtopping Flow on the Wave Dragon Wave Energy Converter

    DEFF Research Database (Denmark)

    Parmeggiani, Stefano; Kofoed, Jens Peter; Friis-Madsen, Erik

    2011-01-01

    The Wave Dragon Wave Energy Converter is currently facing a precommercial phase. At this stage of development a reliable overtopping model is highly required, in order to predict the performance of the device at possible deployment locations. A model formulation derived for an overtopping device...... with general geometry has been used so far. The paper presents an updated formulation drawn through the tank testing of a scaled model the Wave Dragon. The sensitivity analysis of the main features influencing the overtopping flow led to an updated model formulation which can be specifically suited...... for the Wave Dragon....

  8. Turbine Control Strategy using Wave Prediction to Optimise Power Take Off of Overtopping Wave Energy Converters

    OpenAIRE

    Tedd, James; Knapp, Wilfried; Frigaard, Peter; Kofoed, Jens Peter

    2005-01-01

    This paper presents the control strategy used on Wave Dragon overtopping wave energy converter. The nature of overtopping requires that for optimum performance the water level in the reservoir must be controlled by controlling the turbine outflows. A history of the simulations performed is included. The concept of including an element of prediction, based on wave records a short distance in front of the Wave Dragon, is introduced. Initial simulations indicate a possibility to increase product...

  9. Landward Distribution of Wave Overtopping for Rubble Mound Breakwaters

    DEFF Research Database (Denmark)

    Andersen, Thomas Lykke; Burcharth, Hans F.

    2006-01-01

    Overtopping data from seven model test projects has been analyzed with respect to the landward spatial distribution of the overtopping discharge. In total more than 1000 overtopping tests have been analysed and a formula derived for prediction of the landward distribution of overtopping behind...... rubble mound structures with a super structure. The analysis led to the conclusion that although the overtopping discharge, for identical wave heights, decreases with increasing wave steepness, then the maximum travel distance increases with increasing wave steepness....

  10. Surface stability analysis of dikes subject to overtopping and infiltration

    NARCIS (Netherlands)

    Karim, U. F.A.; Tran, Q.T.; Meij, R.

    2015-01-01

    The key contribution of this paper is the coupling of hydraulic loading conditions due to wave overtopping with slope stability of the surface layer of earthen flood protection embankments. Overtopping wave conditions impact overtopping discharges and infiltration time, and thereby the infiltration

  11. Individual Violent Overtopping Events: New Insights

    DEFF Research Database (Denmark)

    Jayaratne, R.; Hunt-Raby, A.; Bullock, G. N.

    2009-01-01

    Wave overtopping is essentially a discrete process in which disastrous consequences can arise from the effect of one or two waves; few of the thousands of previous experiments have focused on the properties of individual events. The violent impacts of water waves on walls create velocities and pr...

  12. Experimental Overtopping Investigation for the Wave Dragon

    DEFF Research Database (Denmark)

    Borgarino, Bruno; Kofoed, Jens Peter; Tedd, James

    The present report displays the results from overtopping tests carried on the 1:51.8 Wave Dragon model in September 2007. This tests have been carried on by Bruno Borgarino, James Tedd and Jens Peter Kofoed in the wave tank facilities of Aalborg University. The objective was to provide an updated...

  13. Geometry Optimization of an Overtopping Wave Energy Device Implemented into the New Breakwater of the Hanstholm Port Expansion

    DEFF Research Database (Denmark)

    Margheritini, Lucia; Stratigaki, Vasiliki; Troch, Peter

    2012-01-01

    breakwater is 1.5 km and the water depth ranges approximately from 8.0 m up to 14 m with localized influences on the wave climate. The study is conducted numerically in order to present the expected power production and overall performance of the SSG breakwater in Hanstholm. The price par kWh is also......The study presented here describes the geometry optimization of the Sea wave Slot cone Generator (SSG) overtopping wave energy converter as part of the feasibility study for the implementation of the device in the development plan of Hanstholm harbour in Denmark. The total length of the new planned...

  14. Innovative rubble mound breakwaters for overtopping wave energy conversion

    DEFF Research Database (Denmark)

    Vicinanza, Diego; Contestabile, Pasquale; Nørgaard, Jørgen Quvang Harck

    2014-01-01

    to the sea through turbines. Wave loadings and average wave overtopping rate at the rear side of the rubble mound breakwater and in the front reservoir are discussed on the basis of physical 2-D model tests carried out at Aalborg University (DK). The experiments have been analyzed and compared with results...... from model tests and wave load design formulae by Nørgaard et al. (2013) for traditional rubble mound crown walls. The existing prediction methods seem unable to predict the hydraulic performances and loadings on the front reservoir and thus new prediction formulae are proposed based on the new...

  15. Overtopping of Rubble Mound Breakwaters with Front Reservoir

    DEFF Research Database (Denmark)

    Burcharth, Hans F.; Andersen, Thomas Lykke

    2007-01-01

    The design and performance of breakwaters with front reservoir are discussed on the basis of physical 2-D model tests with a number of cross sections, in which vertopping discharge and spatial distribution, wave forces on inner parapet walls, and stability of reservoir armour were studied....... The sensitivity of these quantities to the width of the reservoir is discussed. It is demonstrated that front reservoir solutions are more economical than conventional cross section solutions, such as bermed structures and mild slope structures, in cases where low crests and small overtopping discharges...

  16. Experimental Update of the Overtopping Model Used for the Wave Dragon Wave Energy Converter

    Directory of Open Access Journals (Sweden)

    Erik Friis-Madsen

    2013-04-01

    Full Text Available An overtopping model specifically suited for Wave Dragon is needed in order to improve the reliability of its performance estimates. The model shall be comprehensive of all relevant physical processes that affect overtopping and flexible to adapt to any local conditions and device configuration. An experimental investigation is carried out to update an existing formulation suited for 2D draft-limited, low-crested structures, in order to include the effects on the overtopping flow of the wave steepness, the 3D geometry of Wave Dragon, the wing reflectors, the device motions and the non-rigid connection between platform and reflectors. The study is carried out in four phases, each of them specifically targeted at quantifying one of these effects through a sensitivity analysis and at modeling it through custom-made parameters. These are depending on features of the wave or the device configuration, all of which can be measured in real-time. Instead of using new fitting coefficients, this approach allows a broader applicability of the model beyond the Wave Dragon case, to any overtopping WEC or structure within the range of tested conditions. Predictions reliability of overtopping over Wave Dragon increased, as the updated model allows improved accuracy and precision respect to the former version.

  17. Walden North Dam overtopping : emergency response and rehabilitation

    Energy Technology Data Exchange (ETDEWEB)

    Dyer, S. [FortisBC Inc., South Slocan, BC (Canada); McCreanor, J. [Acres International Ltd., Calgary, AB (Canada); Cronin, D.L.R.; Daw, D. [Acres International Ltd., Vancouver, BC (Canada)

    2004-09-01

    This paper described the events that led to the overtopping of the Walden North Dam during a heavy rainfall in June 2002, resulting in a breach around an abutment wall. The dam is part of a run-of-river hydro development on Cayoosh Creek near Lillooet, British Columbia. The Walden North Dam was a low, 46 meter wide concrete dam with a single radial gate. The dam overtopping was attributed to failure of the radial gate hoist. Prior to this event, the dam had been classified by the British Columbia Dam Safety Authorities as a high and then a low consequence category of failure. As facility managers, Aquila Networks Canada Ltd. established an immediate action plan to stabilize the situation and resume normal power production by applying the following priorities: (1) ensure safety of workers and the public, (2) limit further damage to the dam and other facilities, (3) ensure environmental protection, and (4) continue to operate the generation units. Local authorities were informed to evacuate a downstream campsite and environmental agencies were contacted along with safety regulators. Repairs included demolition of the damaged portion of the structure and construction a new two-bay gate/stoplog spillway and bridge. Construction was completed by September 2003 according to the requirements of the Department of Fisheries and Oceans for minimum flow, accurate control of fish flows and environmental monitoring of the stream area. 10 figs.

  18. Overtopping And Rear Slope Stabillity Of Reshaping Breakwaters

    DEFF Research Database (Denmark)

    Burcharth, Hans Falk; Lykke Andersen, Thomas

    2003-01-01

    An experimental study of overtopping and rear slope stability of reshaping breakwaters has been carried out. The variation of those two parameters with crest width, crest freeboard and sea state was investigated. The tests showed that the variation in overtopping discharge with crest freeboard...

  19. Experimental investigation of fluvial dike breaching due to flow overtopping

    Science.gov (United States)

    El Kadi Abderrezzak, K.; Rifai, I.; Erpicum, S.; Archambeau, P.; Violeau, D.; Pirotton, M.; Dewals, B.

    2017-12-01

    The failure of fluvial dikes (levees) often leads to devastating floods that cause loss of life and damages to public infrastructure. Overtopping flows have been recognized as one of the most frequent cause of dike erosion and breaching. Fluvial dike breaching is different from frontal dike (embankments) breaching, because of specific geometry and boundary conditions. The current knowledge on the physical processes underpinning fluvial dike failure due to overtopping remains limited. In addition, there is a lack of a continuous monitoring of the 3D breach formation, limiting the analysis of the key mechanisms governing the breach development and the validation of conceptual or physically-based models. Laboratory tests on breach growth in homogeneous, non-cohesive sandy fluvial dikes due to flow overtopping have been performed. Two experimental setups have been constructed, permitting the investigation of various hydraulic and geometric parameters. Each experimental setup includes a main channel, separated from a floodplain by a dike. A rectangular initial notch is cut in the crest to initiate dike breaching. The breach development is monitored continuously using a specific developed laser profilometry technique. The observations have shown that the breach develops in two stages: first the breach deepens and widens with the breach centerline being gradually shifted toward the downstream side of the main channel. This behavior underlines the influence of the flow momentum component parallel to the dike crest. Second, the dike geometry upstream of the breach stops evolving and the breach widening continues only toward the downstream side of the main channel. The breach evolution has been found strongly affected by the flow conditions (i.e. inflow discharge in the main channel, downstream boundary condition) and floodplain confinement. The findings of this work shed light on key mechanisms of fluvial dike breaching, which differ substantially from those of dam

  20. Steam generator tube performance

    International Nuclear Information System (INIS)

    Tatone, O.S.; Pathania, R.S.

    1984-10-01

    A review of the performance of steam generator tubes in 116 water-cooled nuclear power reactors showed that tubes were plugged at 54 (46 percent) of the reactors. The number of tubes removed from service decreased from 4 692 (0.30 percent) in 1981 to 3 222 (0.20 percent) in 1982. The leading causes of tube failures were stress corrosion cracking from the primary side, stress corrosion cracking (or intergranular attack) from the secondary side and pitting corrosion. The lowest incidence of corrosion-induced defects from the secondary side occurred in reactors that have used only volatile treatment, with or without condensate demineralization

  1. Effects of vertical wall and tetrapod weights on wave overtopping in rubble mound breakwaters under irregular wave conditions

    Directory of Open Access Journals (Sweden)

    Park Sang Kil

    2014-12-01

    Full Text Available Rubble mound breakwaters protect the coastal line against severe erosion caused by wave action. This study examined the performance of different sizes and properties (i.e. height of vertical wall and tetrapod size of rubble mound breakwaters on reducing the overtopping discharge. The physical model used in this study was derived based on an actual rubble mound in Busan Yacht Harbor. This research attempts to fill the gap in practical knowledge on the combined effect of the armor roughness and vertical wall on wave overtopping in rubble mound breakwaters. The main governing parameters used in this study were the vertical wall height, variation of the tetrapod weights, initial water level elevation, and the volume of overtopping under constant wave properties. The experimental results showed that the roughness factor differed according to the tetrapod size. Furthermore, the overtopping discharge with no vertical wall was similar to that with relatively short vertical walls ( 1 γv = 1. Therefore, the experimental results highlight the importance of the height of the vertical wall in reducing overtopping discharge. Moreover, a large tetrapod size may allow coastal engineers to choose a shorter vertical wall to save cost, while obtaining better performance.

  2. Effects of vertical wall and tetrapod weights on wave overtopping in rubble mound breakwaters under irregular wave conditions

    Directory of Open Access Journals (Sweden)

    Sang Kil Park

    2014-12-01

    Full Text Available Rubble mound breakwaters protect the coastal line against severe erosion caused by wave action. This study examined the performance of different sizes and properties (i.e. height of vertical wall and tetrapod size of rubble mound breakwaters on reducing the overtopping discharge. The physical model used in this study was derived based on an actual rubble mound in Busan Yacht Harbor. This research attempts to fill the gap in practical knowledge on the combined effect of the armor roughness and vertical wall on wave overtopping in rubble mound breakwaters. The main governing parameters used in this study were the vertical wall height, variation of the tetrapod weights, initial water level elevation, and the volume of overtopping under constant wave properties. The experimental results showed that the roughness factor differed according to the tetrapod size. Furthermore, the overtopping discharge with no vertical wall was similar to that with relatively short vertical walls (γν = 1. Therefore, the experimental results highlight the importance of the height of the vertical wall in reducing overtopping discharge. Moreover, a large tetrapod size may allow coastal engineers to choose a shorter vertical wall to save cost, while obtaining better performance.

  3. Steam generator tube performance

    International Nuclear Information System (INIS)

    Tatone, O.S.; Pathania, R.S.

    1982-04-01

    The performance of steam generator tubes in water-cooled nuclear power reactors has been reviewed for 1980. Tube defects occurred at 38% of the 97 reactors surveyed. This is a marginal improvement over 1979 when defects occurred at 41% of the reactors. The number of failed tubes was also lower, 0.14% of the tubes in service in 1980 compared with 0.20% of those in service in 1979. Analysis of the causes of these failures indicates that stress corrosion cracking was the leading failure mechanism. Reactors that used all-volatile treatment of secondary water, with or without full-flow condensate demineralization since start-up showed the lowest incidence of corrosion-related defects

  4. Steam generator tube performance

    International Nuclear Information System (INIS)

    Tatone, O.S.; Pathania, R.S.

    1983-08-01

    A review of the performance of steam generator tubes in 110 water-cooled nuclear power reactors showed that tubes were plugged at 46 (42 percent) of the reactors. The number of tubes removed from service increased from 1900 (0.14 percent) in 1980 to 4692 (0.30 percent) in 1981. The leading causes of tube failures were stress corrosion cracking from the primary side, stress corrosion cracking (or intergranular attack) from the secondary side and pitting corrosion. The lowest incidence of corrosion-induced defects from the secondary side occurred in reactors that used all-volatile treatment since start-up. At one reactor a large number of degraded tubes were repaired by sleeving which is expected to become an important method of tube repair in the future

  5. Role of beach morphology in wave overtopping hazard assessment

    Science.gov (United States)

    Phillips, Benjamin; Brown, Jennifer; Bidlot, Jean-Raymond; Plater, Andrew

    2017-04-01

    Understanding the role of beach morphology in controlling wave overtopping volume will further minimise uncertainties in flood risk assessments at coastal locations defended by engineered structures worldwide. XBeach is used to model wave overtopping volume for a 1:200 yr joint probability distribution of waves and water levels with measured, pre- and post-storm beach profiles. The simulation with measured bathymetry is repeated with and without morphological evolution enabled during the modelled storm event. This research assesses the role of morphology in controlling wave overtopping volumes for hazardous events that meet the typical design level of coastal defence structures. Results show disabling storm-driven morphology under-represents modelled wave overtopping volumes by up to 39% under high Hs conditions, and has a greater impact on the wave overtopping rate than the variability applied within the boundary conditions due to the range of wave-water level combinations that meet the 1:200 yr joint probability criterion. Accounting for morphology in flood modelling is therefore critical for accurately predicting wave overtopping volumes and the resulting flood hazard and to assess economic losses.

  6. Comparison of Homogenous and Multi-layered Berm Breakwaters with Respect to Overtopping and Front Slope Stability

    DEFF Research Database (Denmark)

    Andersen, Thomas Lykke; Skals, K. T.; Burcharth, Hans F.

    2009-01-01

    A model test study was conducted to study overtopping and front slope stability of homogenous and multi-layered berm breakwaters. The two breakwater types are compared and cons and pros are listed. The study shows that the optimum number of stone classes might be significantly lower than what has...... previously been used in the Icelandic type of berm breakwater because it seems that the number of stone classes in the berm can be reduced from five to two without significantly influencing overtopping and stability performance. Moreover, the new results are compared to the design formulae established...

  7. Steam generator tube performance

    International Nuclear Information System (INIS)

    Tatone, O.S.; Tapping, R.L.; Stipan, L.

    1992-03-01

    A survey of steam generator operating experience for 1986 has been carried out for 184 pressurized water and pressurized heavy-water reactors, and 1 water-cooled, graphite-moderated reactor. Tubes were plugged at 75 of the reactors (40.5%). In 1986, 3737 tubes were plugged (0.14% of those in service) and 3148 tubes were repaired by sleeving. A small number of reactors accounted for the bulk of the plugged tubes, a phenomenon consistent with previous years. For 1986, the available tubesheet sludge data for 38 reactors has been compiled into tabular form, and sludge/deposit data will be incorporated into all future surveys

  8. Overtopping of Rubble Mound Breakwaters with Front Reservoir

    DEFF Research Database (Denmark)

    Burcharth, Hans F.; Andersen, Thomas Lykke

    2006-01-01

    The admissible overtopping discharge is a key parameter in fundamental design of breakwaters. Quite often there is a wish to limit the crest level of the structure, mainly for aesthetic reasons as a high structure might block the sea view from restaurants, promenades etc.......The admissible overtopping discharge is a key parameter in fundamental design of breakwaters. Quite often there is a wish to limit the crest level of the structure, mainly for aesthetic reasons as a high structure might block the sea view from restaurants, promenades etc....

  9. A Simple model for breach formation by overtopping

    Energy Technology Data Exchange (ETDEWEB)

    Trousseau, P. [Hydro-Quebec, Montreal, PQ (Canada); Kahawita, R. [Ecole Polytechnique, Montreal, PQ (Canada)

    2006-07-01

    Failures in earth or rockfill dams are often caused by overtopping of the crest, leading to initiation and uncontrolled progression of a breach. Overtopping may occur because of large inflows into the reservoir caused by excessive rainfall or by the failure of an upstream dam that causes a large volume of water to suddenly arrive at the downstream reservoir thus rapidly exceeding the storage and spillway evacuation capacity. Breach formation in a rockfill or earthfill dike due to overtopping of the crest is a complex process as it involves interaction between the hydraulics of the flow and the erosion characteristics of the fill material. This paper presented a description and validation of a simple parametric model for breach formation due to overtopping. A study was conducted to model, as closely as possible, the physical processes involved within the restriction of the simplified analysis. The objective of the study was to predict the relevant timescales for the phenomenon leading to a prediction of the outflow hydrograph. The model has been validated on the Oros dam failure in Brazil as well as on embankment tests conducted at Rosvatn, Norway. It was concluded that the major impediment to the development of breach erosion models for use as predictive tools is in the characterization of the erosion behaviour. 19 refs., 2 tabs., 9 figs.

  10. Overtopping Measurements on the Wave Dragon Nissum Bredning Prototype

    DEFF Research Database (Denmark)

    Frigaard, Peter; Kofoed, Jens Peter; Rasmussen, Michael R.

    2004-01-01

    The paper describes the methods used to estimate (calculated from some indirect measurements) the overtopping of the wave energy converter Wave Dragon placed in a real sea environment. The wave energy converter in quistion is the 237-tonne heavy Wave Dragon Nissum Bredning Prototype. Comparisons...

  11. Wave loadings acting on Overtopping Breakwater for Energy Conversion

    DEFF Research Database (Denmark)

    Vicinanza, Diego; Nørgaard, Jørgen Harck; Contestabile, Pasquale

    2013-01-01

    distributions. Load measurements were compared with the most used prediction method for traditional breakwaters, available in the Coastal Engineering Manual (U.S. Army Corps of Engineers, 2002). These results suggest to use the experimental data as design loadings since the design criteria for the innovative......Any kind of Wave Energy Converter (WEC) requires information on reliability of technology and on time required for the return of the investment (reasonable payback). The structural response is one of the most important parameters to take in to account for a consistent assessment on innovative...... devices. This paper presents results on wave loading acting on an hybrid WEC named Overtopping BReakwater for Energy Conversion (OBREC). The new design is based on the concept of an integration between a traditional rubble mound breakwater and a front reservoir designed to store the wave overtopping from...

  12. 3D Tests on Overtopping for SSG Wave Energy Converter

    DEFF Research Database (Denmark)

    Margheritini, Lucia; Kofoed, Jens Peter

    This report presents the results of the first study based on laboratory tests of the behaviour of the SSG pilot module in 3D wave conditions. This study was recommended already during Phase 2 of the Co-operation agreement between WEVEnergy AS (Norway) and Aalborg University, Department of Civil...... of the individual reservoirs have been measured and the hydraulic efficiency calculated. The results are given in terms of overtopping rates for the 3 reservoirs and hydraulic efficiency....

  13. Scale Effects Related to Small Physical Modelling of Overtopping of Rubble Mound Breakwaters

    DEFF Research Database (Denmark)

    Burcharth, Hans F.; Andersen, Thomas Lykke

    2009-01-01

    By comparison of overtopping discharges recorded in prototype and small scale physical models it was demonstrated in the EU-CLASH project that small scale tests significantly underestimate smaller discharges. Deviations in overtopping are due to model and scale effects. These effects are discusse...... armour on the upper part of the slope. This effect is believed to be the main reason for the found deviations between overtopping in prototype and small scale tests....

  14. Steam generator tubing NDE performance

    International Nuclear Information System (INIS)

    Henry, G.; Welty, C.S. Jr.

    1997-01-01

    Steam generator (SG) non-destructive examination (NDE) is a fundamental element in the broader SG in-service inspection (ISI) process, a cornerstone in the management of PWR steam generators. Based on objective performance measures (tube leak forced outages and SG-related capacity factor loss), ISI performance has shown a continually improving trend over the years. Performance of the NDE element is a function of the fundamental capability of the technique, and the ability of the analysis portion of the process in field implementation of the technique. The technology continues to improve in several areas, e.g. system sensitivity, data collection rates, probe/coil design, and data analysis software. With these improvements comes the attendant requirement for qualification of the technique on the damage form(s) to which it will be applied, and for training and qualification of the data analysis element of the ISI process on the field implementation of the technique. The introduction of data transfer via fiber optic line allows for remote data acquisition and analysis, thus improving the efficiency of analysis for a limited pool of data analysts. This paper provides an overview of the current status of SG NDE, and identifies several important issues to be addressed

  15. Model Testing of the Wave Energy Converter Seawave Slot-Cone Generator

    DEFF Research Database (Denmark)

    Kofoed, Jens Peter

    This report presents the results of a preliminary experimental study of the wave energy convert (WEC) Seawave Slot-Cone Generator (SSG). SSG is a WEC utilizing wave overtopping in multiple reservoirs. In the present SSG setup three reservoirs has been used. Model tests have been performed using...... a scale model (length scale 1:15) of a SSG device to be installed on the west coast of the island Kvitsøy near Stavanger, Norway. The tests were carried out at Dept. of Civil Engineering, Aalborg University (AAU) in the 3D deep water wave tank. The model has been subjected to regular and irregular waves...... corresponding to typical conditions off shore from the intended installation site. The overtopping rates for the individual reservoirs have been measured and the potential energy in the overtopping water has been calculated....

  16. Experimental Hydraulic Optimization of the Wave Energy Converter Seawave Slot-Cone Generator

    DEFF Research Database (Denmark)

    Kofoed, Jens Peter

    This report presents the results of a experimental hydraulic optimization of the wave energy convert (WEC) Seawave Slot-Cone Generator (SSG). SSG is a WEC utilizing wave overtopping in multiple reservoirs. In the present SSG setup three reservoirs has been used. Model tests have been performed...

  17. Wave Loadings on Seawave Slot-Cone Generator (SSG) at Kvitsøy Island

    DEFF Research Database (Denmark)

    Vicinanza, Diego; Frigaard, Peter; Kofoed, Jens Peter

    This report presents results from a new research study performed to derive information on wave loadings acting on Wave Energy Convert (WEC) Seawave Slot-Cone Generator (SSG) exposed to extreme wave conditions. The SSG concept is based on the principle of overtopping and stores the wave energy...

  18. Experimental Modelling of the Overtopping Flow on the Wave Dragon Wave Energy Converter

    DEFF Research Database (Denmark)

    Parmeggiani, Stefano; Kofoed, Jens Peter

    The Wave Dragon is a floating slack-moored Wave Energy Converter (WEC) of the overtopping type. Oncoming waves are focused by two wing reflectors towards the ramp of the device, surge-up and overtop into a reservoir placed at a higher level than the surface of the sea. The energy production takes...

  19. Measurements of Overtopping Flow Time Series on the Wave Dragon, Wave Energy Converter

    DEFF Research Database (Denmark)

    Tedd, James; Kofoed, Jens Peter

    2009-01-01

    A study of overtopping flow series on the Wave Dragon prototype, a low crested device designed to maximise flow, in a real sea, is presented. This study aims to fill the gap in the literature on time series of flow overtopping low crested structures. By comparing to a simulated flow the character......A study of overtopping flow series on the Wave Dragon prototype, a low crested device designed to maximise flow, in a real sea, is presented. This study aims to fill the gap in the literature on time series of flow overtopping low crested structures. By comparing to a simulated flow...... the characteristics of the overtopping flow are discussed and the simulation algorithm is tested. Measured data is shown from a storm build up in October 2006, from theWave Dragon prototype situated in an inland sea in Northern Denmark. This wave energy converter extracts energy from the waves, by funnelling them...

  20. Hydrodynamic Behavior of Overtopping Wave Energy Converters Built in Sea Defense Structures

    DEFF Research Database (Denmark)

    Victor, Lander; Kofoed, Jens Peter; Troch, Peter

    2010-01-01

    Many sea defense structures need to be adapted to the rising sea water level and changing wave climate due to global warming. The accordingly required investment opens perspectives for wave energy converters (WECs) – that are built as part of the sea defense structures – to become economically...... viable. In this paper the average overtopping discharges q of overtopping wave energy devices built in sea defense structures are studied. Physical model tests with this type of devices have been carried out in a wave flume leading to experimental q - values. The experimental q -values are compared...... with predicted average overtopping discharges by existing empirical formulae from literature. Overtopping converters have low relative crest freeboards and smooth slope characteristics to maximize overtopping, which is contradictive to the basic role of sea defense structures. As a consequence, the achieved...

  1. Hydraulic Performance of Seawave Slot-Cone Generator Pilot Plant at Kvitsøy (Norway)

    DEFF Research Database (Denmark)

    Margheritini, Lucia; Vicinanza, D.; Kofoed, Jens Peter

    This paper presents results on wave overtopping and loading on an innovative caisson breakwater for electricity production.......This paper presents results on wave overtopping and loading on an innovative caisson breakwater for electricity production....

  2. Experimental evaluation of the effect of wave focusing walls on the performance of the Sea-wave Slot-cone Generator

    International Nuclear Information System (INIS)

    Oliveira, P.; Taveira-Pinto, F.; Morais, T.; Rosa-Santos, P.

    2016-01-01

    Highlights: • The application of the Sea-wave Slot-cone Generator (SSG) in breakwaters is promising. • The use of wave focusing walls (WFW) improves the performance of the SSG technology. • The WFW concentrate the incident wave energy and increase the overtopping flow rates. • The design of new SSG devices should take into account the eventual use of WFW. • The use of WFW increased the annual energy production approximately to the double. - Abstract: The Sea-wave Slot-cone Generator (SSG) is a multi-level overtopping based wave energy converter that can be installed either nearshore or offshore. The installation in harbor breakwaters and in the shoreline presents several advantages despite the usual exposure to smaller waves than at offshore locations. This work analyzes the effect of wave focusing walls (i.e., wave concentrators) on the performance of isolated SSG units using a physical model built on a geometric scale of 1/40. Seven configurations were defined by changing the opening angle and the crest level of those elements. The use of wave concentrators proved to be advantageous since a wider wave front is captured and the run-up and overtopping phenomena are enhanced on the SSG ramp owing to the wave energy concentration (walls tapering effect). In fact, the total mean power captured increased for all SSG configurations with concentrators in comparison to the base configuration (without concentrators), regardless of the sea state considered. In terms of hydraulic performance, the gain associated to the use of wave concentrators depends on the characteristics of incident waves, being higher for the smaller significant wave heights and the shorter peak wave periods. The hydraulic efficiency, defined as the ratio between the total mean power captured per meter of SSG width and the wave power per meter width of the incident waves, increases with the significant wave height and reduces with the peak wave period in all tested SSG configurations. In

  3. Performance diagnostic system for emergency diesel generators

    International Nuclear Information System (INIS)

    Logan, K.P.

    1991-01-01

    Diesel generators are commonly used for emergency backup power at nuclear stations. Emergency diesel generators (EDGs) are subject to both start-up and operating failures, due to infrequent and fast-start use. EDG reliability can be critical to plant safety, particularly when station blackout occurs. This paper describes an expert diagnostic system designed to consistently evaluate the operating performance of diesel generators. The prototype system is comprised of a suite of sensor monitoring, cylinder combustion analyzing, and diagnostic workstation computers. On-demand assessments of generator and auxiliary equipment performance are provided along with color trend displays comparing measured performance to reference-normal conditions

  4. Cleanliness criteria to improve steam generator performance

    International Nuclear Information System (INIS)

    Schwarz, T.; Bouecke, R.; Odar, S.

    2005-01-01

    High steam generator performance is a prerequisite for high plant availability and possible life time extension. The major opponent to that is corrosion and fouling of the heating tubes. Such steam generator degradation problems arise from the continuous ingress of non-volatile contaminants, i.e. corrosion products and salt impurities may accumulate in the steam generators. These impurities have their origin in the secondary side systems. The corrosion products generally accumulate in the steam generators and form deposits not only in the flow restricted areas, such as on top of tube sheet and tube support structure, but also build scales on the steam generator heating tubes. In addition, the tube scales in general affect the steam generator thermal performance, which ultimately causes a reduction of power output. The most effective ways of counteracting all these degradation problems, and thus of improving the steam generator performance is to keep them in clean conditions or, if judged necessary, to plan cleaning measures such as mechanical tube sheet lancing or chemical cleaning. This paper presents a methodology how to assess the cleanliness condition of a steam generator by bringing together all available operational and inspection data such as thermal performance and water chemistry data. By means of this all-inclusive approach the cleanliness condition is quantified in terms of a fouling index. The fouling index allows to monitor the condition of a specific steam generator, compare it to other plants and, finally, to serve as criterion for cleaning measures such as chemical cleaning. The application of the cleanliness criteria and the achieved field results with respect to improvements of steam generator performance will be presented. (author)

  5. Modelling of the Overtopping Flow on the Wave Dragon Wave Energy Converter

    DEFF Research Database (Denmark)

    Parmeggiani, Stefano; Pecher, Arthur; Kofoed, Jens Peter

    2010-01-01

    The Wave Dragon is a floating slack-moored Wave Energy Converter of the overtopping type, which is facing now the last phase of development before the commercial exploitation: the deployment of a full-scale demonstrator. In this phase a modelling tool allowing for accurate predictions of the perf......The Wave Dragon is a floating slack-moored Wave Energy Converter of the overtopping type, which is facing now the last phase of development before the commercial exploitation: the deployment of a full-scale demonstrator. In this phase a modelling tool allowing for accurate predictions...

  6. Analysis of Overtopping Flow on Sea Dikes in Oblique and Short-Crested Waves

    DEFF Research Database (Denmark)

    Nørgaard, Jørgen Harck; Andersen, Thomas Lykke; Burcharth, Hans F.

    2013-01-01

    -empirical formulae for the estimation of flow depths and flow velocities across a dike. The results have been coupled to the actual erosion of the landward dike slope determined by full-scale 2D tests using the so-called “Overtopping Simulator”. This paper describes the results from 96 small-scale tests carried out...... directions on the dike, and the statistical distribution of individual flow parameters are needed to obtain more realistic estimates of dike erosion caused by wave overtopping....

  7. Model Study of Wave Overtopping of Marine Structure for a Wide Range of Geometric Parameters

    DEFF Research Database (Denmark)

    Kofoed, Jens Peter

    2000-01-01

    The objective of the study described in this paper is to enable estimation of wave overtopping rates for slopes/ramps given by a wide range of geometric parameters when subjected to varying wave conditions. To achieve this a great number of model tests are carried out in a wave tank using irregul...... 2-D waves. On the basis of the first part of these tests an exponential overtopping expression for a linear slope, including the effect of limited draught and varying slope angle, is presented. The plans for further tests with other slope geometries are described....

  8. Thermal performances of molten salt steam generator

    International Nuclear Information System (INIS)

    Yuan, Yibo; He, Canming; Lu, Jianfeng; Ding, Jing

    2016-01-01

    Highlights: • Thermal performances of molten salt steam generator were experimentally studied. • Overall heat transfer coefficient reached maximum with optimal molten salt flow rate. • Energy efficiency first rose and then decreased with salt flow rate and temperature. • Optimal molten salt flow rate and temperature existed for good thermal performance. • High inlet water temperature benefited steam generating rate and energy efficiency. - Abstract: Molten salt steam generator is the key technology for thermal energy conversion from high temperature molten salt to steam, and it is used in solar thermal power station and molten salt reactor. A shell and tube type molten salt steam generator was set up, and its thermal performance and heat transfer mechanism were studied. As a coupling heat transfer process, molten salt steam generation is mainly affected by molten salt convective heat transfer and boiling heat transfer, while its energy efficiency is also affected by the heat loss. As molten salt temperature increased, the energy efficiency first rose with the increase of heat flow absorbed by water/steam, and then slightly decreased for large heat loss as the absorbed heat flow still rising. At very high molten salt temperature, the absorbed heat flow decreased as boiling heat transfer coefficient dropping, and then the energy efficiency quickly dropped. As the inlet water temperature increased, the boiling region in the steam generator remarkably expanded, and then the steam generation rate and energy efficiency both rose with the overall heat transfer coefficient increasing. As the molten salt flow rate increased, the wall temperature rose and the boiling heat transfer coefficient first increased and then decreased according to the boiling curve, so the overall heat transfer coefficient first increased and then decreased, and then the steam generation rate and energy efficiency of steam generator both had maxima.

  9. High-resolution marine flood modelling coupling overflow and overtopping processes: framing the hazard based on historical and statistical approaches

    Science.gov (United States)

    Nicolae Lerma, Alexandre; Bulteau, Thomas; Elineau, Sylvain; Paris, François; Durand, Paul; Anselme, Brice; Pedreros, Rodrigo

    2018-01-01

    A modelling chain was implemented in order to propose a realistic appraisal of the risk in coastal areas affected by overflowing as well as overtopping processes. Simulations are performed through a nested downscaling strategy from regional to local scale at high spatial resolution with explicit buildings, urban structures such as sea front walls and hydraulic structures liable to affect the propagation of water in urban areas. Validation of the model performance is based on hard and soft available data analysis and conversion of qualitative to quantitative information to reconstruct the area affected by flooding and the succession of events during two recent storms. Two joint probability approaches (joint exceedance contour and environmental contour) are used to define 100-year offshore conditions scenarios and to investigate the flood response to each scenario in terms of (1) maximum spatial extent of flooded areas, (2) volumes of water propagation inland and (3) water level in flooded areas. Scenarios of sea level rise are also considered in order to evaluate the potential hazard evolution. Our simulations show that for a maximising 100-year hazard scenario, for the municipality as a whole, 38 % of the affected zones are prone to overflow flooding and 62 % to flooding by propagation of overtopping water volume along the seafront. Results also reveal that for the two kinds of statistic scenarios a difference of about 5 % in the forcing conditions (water level, wave height and period) can produce significant differences in terms of flooding like +13.5 % of water volumes propagating inland or +11.3 % of affected surfaces. In some areas, flood response appears to be very sensitive to the chosen scenario with differences of 0.3 to 0.5 m in water level. The developed approach enables one to frame the 100-year hazard and to characterize spatially the robustness or the uncertainty over the results. Considering a 100-year scenario with mean sea level rise (0.6 m), hazard

  10. Nuclear performance standards: Promoting efficient generation

    International Nuclear Information System (INIS)

    Nagelhout, M.

    1990-01-01

    Nuclear plant performance standards are designed to share the risks of operation associated with nuclear generation. Such standards often shift risks from ratepayers to utility shareholders, even without a finding of imprudence or mismanagement. The rationale underlying nuclear performance standards is that ratepayers should not be responsible for excessive replacement power costs incurred as a result of unreasonable decisions by utility management, especially because the high fixed costs of nuclear plants are already included in base rates. In addition, performance standards can be designed to provide incentives to reward utilities that achieve superior nuclear performance, for the benefit of both ratepayers and shareholders

  11. Wave loadings acting on innovative rubble mound breakwater for overtopping wave energy conversion

    DEFF Research Database (Denmark)

    Contestabile, Pasquale; Iuppa, Claudio; Lauro, Enrico Di

    2017-01-01

    Highlights •An innovative breakwater for overtopping wave energy conversion has been studied. •Physical model tests have been carried out and analysed. •Breakwater design information on loadings acting on various parts of the structure has been presented. •Design formulae and validation of some t...

  12. Scale Effects Related to Small Physical Modelling of Overtopping of Rubble Mound Breakwaters

    DEFF Research Database (Denmark)

    Burcharth, Hans F.; Andersen, Thomas Lykke

    2007-01-01

    to avoid damage to the breakwater itself and to objects located behind the breakwater. Extreme overtopping events result in water and spray thrown over the crest with considerable velocities. These events can be extremely dangerous as people, cars and even trains have been washed into the sea. Buildings...

  13. Performance evaluation of an automotive thermoelectric generator

    Science.gov (United States)

    Dubitsky, Andrei O.

    Around 40% of the total fuel energy in typical internal combustion engines (ICEs) is rejected to the environment in the form of exhaust gas waste heat. Efficient recovery of this waste heat in automobiles can promise a fuel economy improvement of 5%. The thermal energy can be harvested through thermoelectric generators (TEGs) utilizing the Seebeck effect. In the present work, a versatile test bench has been designed and built in order to simulate conditions found on test vehicles. This allows experimental performance evaluation and model validation of automotive thermoelectric generators. An electrically heated exhaust gas circuit and a circulator based coolant loop enable integrated system testing of hot and cold side heat exchangers, thermoelectric modules (TEMs), and thermal interface materials at various scales. A transient thermal model of the coolant loop was created in order to design a system which can maintain constant coolant temperature under variable heat input. Additionally, as electrical heaters cannot match the transient response of an ICE, modelling was completed in order to design a relaxed exhaust flow and temperature history utilizing the system thermal lag. This profile reduced required heating power and gas flow rates by over 50%. The test bench was used to evaluate a DOE/GM initial prototype automotive TEG and validate analytical performance models. The maximum electrical power generation was found to be 54 W with a thermal conversion efficiency of 1.8%. It has been found that thermal interface management is critical for achieving maximum system performance, with novel designs being considered for further improvement.

  14. Generating units performances: power system requirements

    Energy Technology Data Exchange (ETDEWEB)

    Fourment, C; Girard, N; Lefebvre, H

    1994-08-01

    The part of generating units within the power system is more than providing power and energy. Their performance are not only measured by their energy efficiency and availability. Namely, there is a strong interaction between the generating units and the power system. The units are essential components of the system: for a given load profile the frequency variation follows directly from the behaviour of the units and their ability to adapt their power output. In the same way, the voltage at the units terminals are the key points to which the voltage profile at each node of the network is linked through the active and especially the reactive power flows. Therefore, the customer will experience the frequency and voltage variations induced by the units behaviour. Moreover, in case of adverse conditions, if the units do not operate as well as expected or trip, a portion of the system, may be the whole system, may collapse. The limitation of the performance of a unit has two kinds of consequences. Firstly, it may result in an increased amount of not supplied energy or loss of load probability: for example if the primary reserve is not sufficient, a generator tripping may lead to an abnormal frequency deviation, and load may have to be shed to restore the balance. Secondly, the limitation of a unit performance results in an economic over-cost for the system: for instance, if not enough `cheap` units are able to load-following, other units with higher operating costs have to be started up. We would like to stress the interest for the operators and design teams of the units on the one hand, and the operators and design teams of the system on the other hand, of dialog and information exchange, in operation but also at the conception stage, in order to find a satisfactory compromise between the system requirements and the consequences for the generating units. (authors). 11 refs., 4 figs.

  15. Generating Performance Models for Irregular Applications

    Energy Technology Data Exchange (ETDEWEB)

    Friese, Ryan D.; Tallent, Nathan R.; Vishnu, Abhinav; Kerbyson, Darren J.; Hoisie, Adolfy

    2017-05-30

    Many applications have irregular behavior --- non-uniform input data, input-dependent solvers, irregular memory accesses, unbiased branches --- that cannot be captured using today's automated performance modeling techniques. We describe new hierarchical critical path analyses for the \\Palm model generation tool. To create a model's structure, we capture tasks along representative MPI critical paths. We create a histogram of critical tasks with parameterized task arguments and instance counts. To model each task, we identify hot instruction-level sub-paths and model each sub-path based on data flow, instruction scheduling, and data locality. We describe application models that generate accurate predictions for strong scaling when varying CPU speed, cache speed, memory speed, and architecture. We present results for the Sweep3D neutron transport benchmark; Page Rank on multiple graphs; Support Vector Machine with pruning; and PFLOTRAN's reactive flow/transport solver with domain-induced load imbalance.

  16. Performance assessment of Point Lepreau Generating Station

    Energy Technology Data Exchange (ETDEWEB)

    Alikhan, S [Point Lepreau Generating Station, Lepreau, NB (Canada)

    1991-04-01

    The Point Lepreau Generating Station, a 680 MWe CANDU unit, is located about 40 km southwest of the city of Saint John, New Brunswick, Canada. It was declared in-service on 1 February, 1983 and, since then, has demonstrated an average cross capacity factor of over 93% up to the end of 1990. This paper compared the performance of the station with other sister CANDU units and the Light Water Reactors world-wide using the following ten performance indicators, as applicable: - gross capacity factor; - fuel burn-up; - heavy water upkeep; - unplanned reactor trips while critical; - forced outage rate; - fuel handling performance; - derived emission of radioactive effluents to environment; - personnel radiation dose; - industrial safety; - low-level solid radioactive wastes. The paper examines various areas of station activities including management and organization, operations and maintenance, technical support, fuel handling and health physics in order to highlight some of the 'good practices' which are believed to have made a significant contribution towards achieving the demonstrated performance of Point Lepreau G.S. In addition, several areas of potential improvement are discussed in order to maintain and enhance, where practicable, the safety, reliability and economic performance of the station. In this context, a careful review of the operating experiences, both in-house and at other stations, and a judicious application of lessons learned plays a significant role. (author)

  17. Performance assessment of Point Lepreau Generating Station

    International Nuclear Information System (INIS)

    Alikhan, S.

    1991-01-01

    The Point Lepreau Generating Station, a 680 MWe CANDU unit, is located about 40 km southwest of the city of Saint John, New Brunswick, Canada. It was declared in-service on 1 February, 1983 and, since then, has demonstrated an average cross capacity factor of over 93% up to the end of 1990. This paper compared the performance of the station with other sister CANDU units and the Light Water Reactors world-wide using the following ten performance indicators, as applicable: - gross capacity factor; - fuel burn-up; - heavy water upkeep; - unplanned reactor trips while critical; - forced outage rate; - fuel handling performance; - derived emission of radioactive effluents to environment; - personnel radiation dose; - industrial safety; - low-level solid radioactive wastes. The paper examines various areas of station activities including management and organization, operations and maintenance, technical support, fuel handling and health physics in order to highlight some of the 'good practices' which are believed to have made a significant contribution towards achieving the demonstrated performance of Point Lepreau G.S. In addition, several areas of potential improvement are discussed in order to maintain and enhance, where practicable, the safety, reliability and economic performance of the station. In this context, a careful review of the operating experiences, both in-house and at other stations, and a judicious application of lessons learned plays a significant role. (author)

  18. Performance study of thermo-electric generator

    Science.gov (United States)

    Rohit, G.; Manaswini, D.; Kotebavi, Vinod; R, Nagaraja S.

    2017-07-01

    Devices like automobiles, stoves, ovens, boilers, kilns and heaters dissipate large amount of waste heat. Since most of this waste heat goes unused, the efficiency of these devices is drastically reduced. A lot of research is being conducted on the recovery of the waste heat, among which Thermoelectric Generators (TEG) is one of the popular method. TEG is a semiconductor device that produces electric potential difference when a thermal gradient develops on it. This paper deals with the study of performance of a TEG module for different hot surface temperatures. Performance characteristics used here are voltage, current and power developed by the TEG. One side of the TEG was kept on a hot plate where uniform heat flux was supplied to that. And the other side was cooled by supplying cold water. The results show that the output power increases significantly with increase in the temperature of the hot surface.

  19. Study of Dam-break Due to Overtopping of Four Small Dams in the Czech Republic

    Directory of Open Access Journals (Sweden)

    Zakaraya Alhasan

    2015-01-01

    Full Text Available Dam-break due to overtopping is one of the most common types of embankment dam failures. During the floods in August 2002 in the Czech Republic, several small dams collapsed due to overtopping. In this paper, an analysis of the dam break process at the Luh, Velký Bělčický, Melín, and Metelský dams breached during the 2002 flood is presented. Comprehensive identification and analysis of the dam shape, properties of dam material and failure scenarios were carried out after the flood event to assemble data for the calibration of a numerical dam break model. A simple one-dimensional mathematical model was proposed for use in dam breach simulation, and a computer code was compiled. The model was calibrated using the field data mentioned above. Comparison of the erodibility parameters gained from the model showed reasonable agreement with the results of other authors.

  20. Recruitment of ichthyoplankton and macrozooplankton during overtopping events into a temporarily open/closed southern African estuary

    Science.gov (United States)

    Kemp, J. O. G.; Froneman, P. W.

    2004-11-01

    The composition and short-term temporal variation in the ichthyofauna and macrozooplankton entering the temporarily open/closed (TOC) West Kleinemond estuary (33°33'S, 27°02'E) during 7 overtopping events were investigated in June 2003. A total of 84 fish representing 7 taxa from 6 families and 456 macrozooplankton representing at least 16 species was collected from water overtopping the sandbar using a custom-built funnel trap (150 μm mesh). Larvae of estuarine dependant marine species, especially the sparid, Rhabdosargus holubi, which contributed 54% to the total fish catch, dominated the ichthyofauna. Also well represented among the ichthyofauna were Monodactylus falciformis and Mugilidae spp., which together accounted for a further 40% of the total fish catch. Among the macrozooplankton, larvae of Palaemon peringueyi and the mysid Mesopodopsis wooldridgei dominated numerically and by biomass. Numerical analyses using multidimensional scaling (MDS) revealed variability in the overtopping community on a diel scale. It is suggested that recruitment through overtopping is essentially a passive process governed by the physical environment with the composition of the recruiting community being a function of the patchy dynamics of surf zone plankton. Preliminary estimates indicate that an hour-long period of overtopping over spring high tide is capable of introducing between 8000 and 33 500 individuals of R. holubi into the TOC West Kleinemond estuary. The advantages and disadvantages of recruitment using overtopping events as well as impacts on the estuarine foodweb are discussed.

  1. Analysis of fast reactor steam generator performance

    International Nuclear Information System (INIS)

    Hulme, G.; Curzon, A.F.

    1992-01-01

    A computer model for the prediction of flow and temperature fields within a fast reactor steam generator unit is described. The model combines a commercially available computational fluid dynamics (CFD) solver (PHOENICS) with a steam-tube calculation and provides solutions for the fully coupled flow and temperature fields on both the shell side and the tube side. The model includes the inlet and outlet headers and the bottom end stagnant zone. It also accounts for the effects of support grids and edge-gaps. Two and three dimensional and transient calculations have been performed for both straight tube and J-tube units. Examples of the application of the model are presented. (7 figures) (Author)

  2. Operating performance of LWR nuclear generating units

    International Nuclear Information System (INIS)

    Pia, S.

    1984-01-01

    This work aims at reviewing, on the basis of historical data, the operational problem areas which explain the degree of availability and productivity achieved up to now by nuclear power plants in commercial operation in the world. The operating performance data of nuclear power plants area analysed with respect to plant type, size and other significant reference parameters and they are evaluated also by comparison with fossil generating unit data. Major performance indices data are presented for both nuclear and fossil units type and distribution of outage causes. Unplanned full outages caused by nuclear power plant equipment and components failure are particulary emphasized. The trend for unplanned full outages due to the failure of components shows decreasing numerical values in 1981 with respect to the previous years. But this result should be weighed with the increasing plant unavailability hours needed for maintenance and repair action (chiefly preventive maintenance on critical components). This means that the number and downtime of forced outage must be drastically reduced for economic reasons (production losses and problems associated with the unavailable unit unplanned replacement) as well as for plant safe and reliable operation (sudden unavailability of key components and frequency of transients associated with plant shutdown and routine startup operation)

  3. Superlattice design for optimal thermoelectric generator performance

    Science.gov (United States)

    Priyadarshi, Pankaj; Sharma, Abhishek; Mukherjee, Swarnadip; Muralidharan, Bhaskaran

    2018-05-01

    We consider the design of an optimal superlattice thermoelectric generator via the energy bandpass filter approach. Various configurations of superlattice structures are explored to obtain a bandpass transmission spectrum that approaches the ideal ‘boxcar’ form, which is now well known to manifest the largest efficiency at a given output power in the ballistic limit. Using the coherent non-equilibrium Green’s function formalism coupled self-consistently with the Poisson’s equation, we identify such an ideal structure and also demonstrate that it is almost immune to the deleterious effect of self-consistent charging and device variability. Analyzing various superlattice designs, we conclude that superlattice with a Gaussian distribution of the barrier thickness offers the best thermoelectric efficiency at maximum power. It is observed that the best operating regime of this device design provides a maximum power in the range of 0.32–0.46 MW/m 2 at efficiencies between 54%–43% of Carnot efficiency. We also analyze our device designs with the conventional figure of merit approach to counter support the results so obtained. We note a high zT el   =  6 value in the case of Gaussian distribution of the barrier thickness. With the existing advanced thin-film growth technology, the suggested superlattice structures can be achieved, and such optimized thermoelectric performances can be realized.

  4. Operational performance of generator condition monitors

    International Nuclear Information System (INIS)

    Braun, J.M.; Brown, G.

    1990-01-01

    This paper reports on the generator condition monitor (GCM) developed in an attempt to detect overheating inside large turbine generators. As part of a broader study on rotating machinery diagnostics, generator condition monitors were evaluated under field conditions in a 550 MW turbogenerator. Small 100 W resistors coated with insulating paints and varnishes were mounted inside the generator to simulate insulation overheating. The GCM responded very rapidly to an overheating event, typically within two minutes, even for hot spots as small s 10 cm 2 . Similarly the aerosols produced on overheating were found extremely short lived, decaying within two to three minutes after overheating was discontinued. Use of heated ion chambers was found to desensitize the GCM regardless of the nature of the overheated insulation and in some cases would altogether prevent the GCM from reaching the 50% pre-set alarm level commonly used on GCMs

  5. Development of a Generic Power Simulation Tool for Overtopping Based WEC

    DEFF Research Database (Denmark)

    Bogarino, Bruno; Kofoed, Jens Peter; Meinert, Palle

    The overtopping based wave energy converters work by collecting the water from waves in one or more reservoirs above the mean sea water level. The water is then evacuated through one or several turbines and thereby produces electrical energy. As the waves in real sea have a stochastic variation...... in wave height and period, it is very difficult to predict how much water the next wave will bring. Thus, for a given wave state, an optimum turbine operating strategy must be found, minimising the sum of head and spilling losses over a certain period of time. This can only be done by modelling...

  6. Overtopping hazards to port activities: Application of a new methodology to risk management (POrt Risk MAnagement Tool)

    International Nuclear Information System (INIS)

    Alises, Ana; Molina, Rafael; Gómez, Rebeca; Pery, Pascual; Castillo, Carmen

    2014-01-01

    In the past 20 years, the need of ports to serve a fleet whose dimensions are continuously increasing due to economies of scale, has derived on a port infrastructures growth with a trend to look for greater drafts at deeper waters and therefore the protection structures built in the last years have been increasingly exposed to severer maritime climate action. Consequently, overtopping phenomenon has been identified as a potential risk factor able to cause structural damages and operative failure modes to vulnerable economic activities located at these port facilities. Port activities must be developed ensuring operative and safety conditions what imply reducing uncertainties of overtopping phenomena by using prediction methods which may allow overtopping risk management. This paper provides a risk assessment methodology which is integrated into an overtopping risk management framework to cope with safety problems in port exploitation. Overtopping risk value is measured by combining probability of occurrence of an undesirable event together with its consequences, estimated in terms of costs or delays and given in base of the vulnerability of the affected port system. The development of this methodology is described and finally applied to a real case study what seems to reinforce the validity of the proposed method to overtopping risk assessment. - Highlights: • Infrastructure risk assessment involves both probabilistic and economic techniques. • Risk equation is posed by the combination of probability, vulnerability and cost. • Port infrastructures' vulnerability level depends on climate agents' action. • Economic value of natural hazards consequences is linked with vulnerability level. • Project planning process should be done taking into account the project's risk distribution

  7. Materials performance in operating PWR steam generators

    International Nuclear Information System (INIS)

    Weeks, J.R.

    1975-01-01

    The Inconel-600 tubing in operating PWR steam generators has developed leaks due to intergranular stress corrosion cracking or a general wastage attack, originating from the secondary side of the tubing. Corrosion has been limited to those areas of the steam generators where limited coolant circulation and high heat flux have caused impurities to concentrate. Wastage or pitting attack has always been associated with local concentration of sodium hydrogen phosphates, whereas stress corrosion has been associated with local concentration of sodium or potassium hydroxides. The only instance of stress corrosion originating from the primary side occurred on cold-worked tubing when hydrogen was not added to getter oxygen, and LiOH was not added to raise the pH of the primary coolant. All PWR manufacturers are now recommending that the phosphate treatment of the secondary coolant be abandoned in favor of an all-volatile treatment. Experience in operating plants has shown, however, that removal of phosphate-rich sludge deposits is difficult, and that further wastage and/or intergranular stress corrosion may develop; the residual sodium phosphates gradually convert by reaction with corrosion product hydroxides to sodium hydroxide, which remains concentrated in the limited flow areas. Improvements in circulation patterns have been achieved by inserting flow baffles in some PWR steam generators. Inservice monitoring by eddy current techniques is useful for detecting corrosion-induced defects in the tubing, but irreproducibility in field examinations can lead to uncertainties interpreting the results. (U.S.)

  8. Design and performance of chromium mist generator

    Directory of Open Access Journals (Sweden)

    Tirgar Aram

    2006-01-01

    Full Text Available Chromium mist generator is an essential tool for conducting researches and making science-based recommendations to evaluate air pollution and its control systems. The purpose of this research was to design and construct a homogenous chromium mist generator and the study of some effective factors including sampling height and distances between samplers in side-by-side sampling on chromium mist sampling method. A mist generator was constructed, using a chromium electroplating bath in pilot scale. Concentration of CrO3 and sulfuric acid in plating solution was 125 g L-1 and 1.25 g L-1, respectively. In order to create permanent air sampling locations, a Plexiglas cylindrical chamber (75 cm height, 55 cm i.d was installed the bath overhead. Sixty holes were produced on the chamber in 3 rows (each 20. The distance between rows and holes was 15 and 7.5 cm, respectively. Homogeneity and effective factors were studied via side-by-side air sampling method. So, 48 clusters of samples were collected on polyvinyl chloride (PVC filters housed in sampling cassettes. Cassettes were located in 35, 50, and 65 cm above the solution surface with less than 7.5 and/or 7.5-15 cm distance between heads. All samples were analyzed according to the NIOSH method 7600. According to the ANOVA test, no significant differences were observed between different sampling locations in side-by-side sampling (P=0.82 and between sampling heights and different samplers distances (P=0.86 and 0.86, respectively. However, there were notable differences between means of coefficient of variations (CV in various heights and distances. It is concluded that the most chromium mist homogeneity could be obtained at height 50 cm from the bath solution surface and samplers distance of < 7.5 cm.

  9. Uncertainty Analysis and Overtopping Risk Evaluation of Maroon Dam withMonte Carlo and Latin Hypercube Methods

    Directory of Open Access Journals (Sweden)

    J. M. Vali Samani

    2016-02-01

    Full Text Available Introduction: The greatest part of constructed dams belongs to embankment dams and there are many examples of their failures throughout history. About one-third of the world’s dam failures have been caused by flood overtopping, which indicates that flood overtopping is an important factor affecting reservoir projects’ safety. Moreover, because of a poor understanding of the randomness of floods, reservoir water levels during flood seasons are often lowered artificially in order to avoid overtopping and protect the lives and property of downstream residents. So, estimation of dam overtopping risk with regard to uncertainties is more important than achieving the dam’s safety. This study presents the procedure for risk evaluation of dam overtopping due to various uncertaintiess in inflows and reservoir initial condition. Materials and Methods: This study aims to present a practical approach and compare the different uncertainty analysis methods in the evaluation of dam overtopping risk due to flood. For this purpose, Monte Carlo simulation and Latin hypercube sampling methods were used to calculate the overtopping risk, evaluate the uncertainty, and calculate the highest water level during different flood events. To assess these methods from a practical point of view, the Maroon dam was chosen for the case study. Figure. 1 indicates the work procedure, including three parts: 1 Identification and evaluation of effective factors on flood routing and dam overtopping, 2 Data collection and analysis for reservoir routing and uncertainty analysis, 3 Uncertainty and risk analysis. Figure 1- Diagram of dam overtopping risk evaluation Results and Discussion: Figure 2 shows the results of the computed overtopping risks for the Maroon Dam without considering the wind effect, for the initial water level of 504 m as an example. As it is shown in Figure. 2, the trends of the risk curves computed by the different uncertainty analysis methods are similar

  10. Performance of new generation pole light

    International Nuclear Information System (INIS)

    Foo, K C; Karunanithi, S; Thio, G

    2013-01-01

    This paper describes the design and implementation of a standalone photovoltaic power supply which caters for garden lighting scheme. New Generation Pole Light (NGPL) consists of three parts which are light dependent resistor (LDR) and pyroelectric infrared (PIR) sensors, microcontroller and light emitting diode (LED) and finally, solar charging system. During the night, LED is switched on with two operating modes which are ultra-bright lighting for a predetermine period (when human presence is detected) and dim lighting. Meanwhile, LED is switched off at day time and solar charging system will recover the capacity of discharged battery. NGPL provides portable, sustainable, environmental friendly and requires minimal maintenance for outdoor lighting scheme for both urban and rural areas.

  11. Performance of cryogenic thermoelectric generators in LNG cold energy utilization

    International Nuclear Information System (INIS)

    Sun Wei; Hu Peng; Chen Zeshao; Jia Lei

    2005-01-01

    The cold energy of liquefied natural gas (LNG) is generally wasted when the LNG is extracted for utilization. This paper proposes cryogenic thermoelectric generators to recover this cold energy. The theoretical performance of the generator has been analyzed. An analytical method and numerical method of calculation of the optimum parameters of the generator have been demonstrated

  12. An assessment of long-term overtopping risk and optimal termination time of dam under climate change.

    Science.gov (United States)

    Lee, Bau-Shian; You, Gene Jiing-Yun

    2013-05-30

    Reservoir management faces a wide range of new challenges resulting from the impact of climate change. One set of challenges arises from the non-stationary nature of hydrological conditions. Another crucial issue is watershed sedimentation, which can significantly influence the sustainability and safety of reservoirs. To address these concerns, this study developed a framework for the management of reservoir risk. An analytical conceptual model coupling physical governing relationships and economic tools was proposed, which was then applied to the Shihmen Reservoir in Taiwan. We adopted a statistical representation of future hydrologic conditions with the assumption of time-variant moments and focused on evaluating the impact of an increase in the frequency of extreme hydrological events caused by climate change and used a stochastic approach to quantify the risk factors. Our results confirm that this approach can be used to identify reservoir-related risks and generate appropriate options for strategy and policy. We determined that the major source of risk is the hydrological conditions, especially the extreme events. More severe intra-annual climatic change is much more dominant in the risk compared to inter-year trends. The influence of reservoir characteristics on risk is associated mainly with the availability of flood control capacity, but limited due to the limitation of its volume and potential to regulate the flow. Engineering may provide an option for mitigating the risk, but integrated, watershed-level approaches, such as providing systematic detention or land use management, are better suited to reducing the storm peak from a long-term perspective. With a critical increase in the risk of overtopping, a high probability of dam failure and corresponding losses may precipitate the need to retire or remove the facility. However, because the benefits and costs are both huge, the decision may be biased by a conservative attitude. The outcome of small

  13. Thermal Model Predictions of Advanced Stirling Radioisotope Generator Performance

    Science.gov (United States)

    Wang, Xiao-Yen J.; Fabanich, William Anthony; Schmitz, Paul C.

    2014-01-01

    This presentation describes the capabilities of three-dimensional thermal power model of advanced stirling radioisotope generator (ASRG). The performance of the ASRG is presented for different scenario, such as Venus flyby with or without the auxiliary cooling system.

  14. Assess and Predict Automatic Generation Control Performances for Thermal Power Generation Units Based on Modeling Techniques

    Science.gov (United States)

    Zhao, Yan; Yang, Zijiang; Gao, Song; Liu, Jinbiao

    2018-02-01

    Automatic generation control(AGC) is a key technology to maintain real time power generation and load balance, and to ensure the quality of power supply. Power grids require each power generation unit to have a satisfactory AGC performance, being specified in two detailed rules. The two rules provide a set of indices to measure the AGC performance of power generation unit. However, the commonly-used method to calculate these indices is based on particular data samples from AGC responses and will lead to incorrect results in practice. This paper proposes a new method to estimate the AGC performance indices via system identification techniques. In addition, a nonlinear regression model between performance indices and load command is built in order to predict the AGC performance indices. The effectiveness of the proposed method is validated through industrial case studies.

  15. Wave Overtopping over Crown Walls and Run-up on Rubble Mound Breakwaters with Kolos Armour under Random Waves

    Directory of Open Access Journals (Sweden)

    A. Arunjith

    2013-06-01

    Full Text Available The design of rubble mound structures like breakwaters and seawalls are influenced by the wave run-up and overtopping over them. The above phenomena largely depend on the type of the armour units as they directly interact with the incident waves. The hydrodynamic characteristics of various concrete armour units have been established by several researchers. A new armour block, ‘Kolos’, a modified version of Dolos, is considered in this study for a detailed investigation. An attempt is made to establish empirical relationships for the estimation of wave overtopping discharges over crown wall and run-up on Kolosarmoured slope exposed to random wave from the results of a comprehensive experimental program. Further, the results are compared with that of a tested section with natural rocks as armour layer and with that of other investigators.

  16. Prediction of the Individual Wave Overtopping Volumes of a Wave Energy Converter using Experimental Testing and First Numerical Model Results

    DEFF Research Database (Denmark)

    Victor, L.; Troch, P.; Kofoed, Jens Peter

    2009-01-01

    For overtopping wave energy converters (WECs) a more efficient energy conversion can be achieved when the volumes of water, wave by wave, that enter their reservoir are known and can be predicted. A numerical tool is being developed using a commercial CFD-solver to study and optimize...... nearshore 2Dstructure. First numerical model results are given for a specific test with regular waves, and are compared with the corresponding experimental results in this paper....

  17. Wave Overtopping over Crown Walls and Run-up on Rubble Mound Breakwaters with Kolos Armour under Random Waves

    OpenAIRE

    A. Arunjith; S.A. Sannasiraj; V. Sundar

    2013-01-01

    The design of rubble mound structures like breakwaters and seawalls are influenced by the wave run-up and overtopping over them. The above phenomena largely depend on the type of the armour units as they directly interact with the incident waves. The hydrodynamic characteristics of various concrete armour units have been established by several researchers. A new armour block, ‘Kolos’, a modified version of Dolos, is considered in this study for a detailed investigation. An attempt is made to ...

  18. Performance of Generating Plant: New Metrics for Industry in Transition

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-09-15

    This report is the result of the work of the Performance of Generating Plant task force of the World Energy Council. The report examines the challenges of measuring and improving performance and considers some of the issues related to this field.

  19. MHD generator performance analysis for the Advanced Power Train study

    Science.gov (United States)

    Pian, C. C. P.; Hals, F. A.

    1984-01-01

    Comparative analyses of different MHD power train designs for early commercial MHD power plants were performed for plant sizes of 200, 500, and 1000 MWe. The work was conducted as part of the first phase of a planned three-phase program to formulate an MHD Advanced Power Train development program. This paper presents the results of the MHD generator design and part-load analyses. All of the MHD generator designs were based on burning of coal with oxygen-enriched air preheated to 1200 F. Sensitivities of the MHD generator design performance to variations in power plant size, coal type, oxygen enrichment level, combustor heat loss, channel length, and Mach number were investigated. Basd on these sensitivity analyses, together with the overall plant performance and cost-of-electricity analyses, as well as reliability and maintenance considerations, a recommended MHD generator design was selected for each of the three power plants. The generators for the 200 MWe and 500 MWe power plant sizes are supersonic designs. A subsonic generator design was selected for the 1000 MWe plant. Off-design analyses of part-load operation of the supersonic channel selected for the 200 MWe power plant were also conductd. The results showed that a relatively high overall net plant efficiency can be maintained during part-laod operation with a supersonic generator design.

  20. Very high performance pseudo-random number generation on DAP

    Science.gov (United States)

    Smith, K. A.; Reddaway, S. F.; Scott, D. M.

    1985-07-01

    Since the National DAP Service began at QMC in 1980, extensive use has been made of pseudo-random numbers in Monte Carlo simulation. Matrices of uniform numbers have been produced by various generators: (a) multiplicative ( x+ 1 = 13 13xn mod 2 59); (b) very long period shift register ( x4423 + x271 + 1); (c) multiple shorter period ( x127 + x7 + 1) shift registers generating several matrices per iteration. The above uniform generators can also feed a normal distribution generator that uses the Box-Muller transformation. This paper describes briefly the generators, their implementation and speed. Generator (b) has been greatly speeded-up by re-implementation, and now produces more than 100 × 10 6 high quality 16-bit numbers/s. Generator (c) is under development and will achieve even higher performance, mainly due to producing data in greater bulk. High quality numbers are expected, and performance will range from 400 to 800 × 10 6 numbers/s, depending on how the generator is used.

  1. Performance demonstration requirements for eddy current steam generator tube inspection

    International Nuclear Information System (INIS)

    Kurtz, R.J.; Heasler, P.G.; Anderson, C.M.

    1992-10-01

    This paper describes the methodology used for developing performance demonstration tests for steam generator tube eddy current (ET) inspection systems. The methodology is based on statistical design principles. Implementation of a performance demonstration test based on these design principles will help to ensure that field inspection systems have a high probability of detecting and correctly sizing tube degradation. The technical basis for the ET system performance thresholds is presented. Probability of detection and flaw sizing tests are described

  2. Economic Assessment of Overtopping BReakwater for Energy Conversion (OBREC: A Case Study in Western Australia

    Directory of Open Access Journals (Sweden)

    Pasquale Contestabile

    2016-12-01

    Full Text Available This paper constructs an optimal configuration assessment, in terms of the financial returns, of the Overtopping BReakwater for wave Energy Conversion (OBREC. This technology represents a hybrid wave energy harvester, totally embedded in traditional rubble mound breakwaters. Nine case studies along the southern coast of Western Australia have been analysed. The technique provides tips on how to estimate the quality of the investments, for benchmarking with different turbine strategy layouts and overlapping with the costs of traditional rubble mound breakwaters. Analyses of the offshore and nearshore wave climate have been studied by a high resolution coastal propagation model, forced with wave data from the European Centre for Medium-Range Weather Forecasts (ECMWF. Inshore wave conditions have been used to quantify the exploitable resources. It has been demonstrated that the optimal investment strategy is nonlinearly dependent on potential electricity production due to outer technical constraints. The work emphasizes the importance of integrating energy production predictions in an economic decision framework for prioritizing adaptation investments.

  3. Survey of regulatory agency review of generating unit performance

    International Nuclear Information System (INIS)

    Roach, E.M. Jr.; Tarletz, D.B.

    1985-01-01

    Regulatory agencies across the country are being called upon increasingly to monitor the management of electric utilities. Such activity, which once was relatively rare, is now common. Most frequently this oversight centers around the operating performance of generating units, both nuclear and fossil. There are, perhaps, several reasons for this increased interest in the efficient operation of generating units: increased fuel costs and fuel cost differentials, increased lead times and costs for construction of new generating units, and increased dependence on existing units because of construction programs being revised to meet decreased load growth. The monitoring of generating units has taken the form of after the fact evaluation of performance on a case-by-case basis and the implementation of productivity incentive programs. Performance standards are used in these contexts both to measure the adequacy of unit performance and to implement incentives in the form of rewards or penalties. The standard used may be a subjective test of prudent performance or some numerical index of plant performance, e.g., equivalent availability, capacity factor or heat rate. Some of the activity by regulators is reviewed in applying subjective and numerical standards and the considerations involved in applying such standards are discussed

  4. Framing 100-year overflowing and overtopping marine submersion hazard resulting from the propagation of 100-year joint hydrodynamic conditions

    Science.gov (United States)

    Nicolae Lerma, A.; Bulteau, T.; Elineau, S.; Paris, F.; Pedreros, R.

    2016-12-01

    Marine submersion is an increasing concern for coastal cities as urban development reinforces their vulnerabilities while climate change is likely to foster the frequency and magnitude of submersions. Characterising the coastal flooding hazard is therefore of paramount importance to ensure the security of people living in such places and for coastal planning. A hazard is commonly defined as an adverse phenomenon, often represented by a magnitude of a variable of interest (e.g. flooded area), hereafter called response variable, associated with a probability of exceedance or, alternatively, a return period. Characterising the coastal flooding hazard consists in finding the correspondence between the magnitude and the return period. The difficulty lies in the fact that the assessment is usually performed using physical numerical models taking as inputs scenarios composed by multiple forcing conditions that are most of the time interdependent. Indeed, a time series of the response variable is usually not available so we have to deal instead with time series of forcing variables (e.g. water level, waves). Thus, the problem is twofold: on the one hand, the definition of scenarios is a multivariate matter; on the other hand, it is tricky and approximate to associate the resulting response, being the output of the physical numerical model, to the return period defined for the scenarios. In this study, we illustrate the problem on the district of Leucate, located in the French Mediterranean coast. A multivariate extreme value analysis of waves and water levels is performed offshore using a conditional extreme model, then two different methods are used to define and select 100-year scenarios of forcing variables: one based on joint exceedance probability contours, a method classically used in coastal risks studies, the other based on environmental contours, which are commonly used in the field of structure design engineering. We show that these two methods enable one to

  5. A programmable Gaussian random pulse generator for automated performance measurements

    International Nuclear Information System (INIS)

    Abdel-Aal, R.E.

    1989-01-01

    This paper describes a versatile random signal generator which produces logic pulses with a Gaussian distribution for the pulse spacing. The average rate at the pulse generator output can be software-programmed, which makes it useful in performing automated measurements of dead time and CPU time performance of data acquisition systems and modules over a wide range of data rates. Hardware and software components are described and data on the input-output characteristics and the statistical properties of the pulse generator are given. Typical applications are discussed together with advantages over using radioactive test sources. Results obtained from an automated performance run on a VAX 11/785 data acquisition system are presented. (orig.)

  6. Design of High Performance Permanent-Magnet Synchronous Wind Generators

    Directory of Open Access Journals (Sweden)

    Chun-Yu Hsiao

    2014-11-01

    Full Text Available This paper is devoted to the analysis and design of high performance permanent-magnet synchronous wind generators (PSWGs. A systematic and sequential methodology for the design of PMSGs is proposed with a high performance wind generator as a design model. Aiming at high induced voltage, low harmonic distortion as well as high generator efficiency, optimal generator parameters such as pole-arc to pole-pitch ratio and stator-slot-shoes dimension, etc. are determined with the proposed technique using Maxwell 2-D, Matlab software and the Taguchi method. The proposed double three-phase and six-phase winding configurations, which consist of six windings in the stator, can provide evenly distributed current for versatile applications regarding the voltage and current demands for practical consideration. Specifically, windings are connected in series to increase the output voltage at low wind speed, and in parallel during high wind speed to generate electricity even when either one winding fails, thereby enhancing the reliability as well. A PMSG is designed and implemented based on the proposed method. When the simulation is performed with a 6 Ω load, the output power for the double three-phase winding and six-phase winding are correspondingly 10.64 and 11.13 kW. In addition, 24 Ω load experiments show that the efficiencies of double three-phase winding and six-phase winding are 96.56% and 98.54%, respectively, verifying the proposed high performance operation.

  7. The performance of gel technetium-99m generator

    International Nuclear Information System (INIS)

    Liu Yishu

    2004-01-01

    Technetium-99m, as one of the important radionuclides in nuclear medical science, has been widely used for diseases diagnosis in both developed and developing countries for many years. Technetium-99m can be obtained from both fission-type and gel-type Tc-99m generator. Fission-type generator was prepared by Molybdenum-99 separated from fission products of uranium-235 and gel-type was prepared by irradiating nature MoO 3 in reactor, and a series of chemical and physical processes. This paper briefly describes the manufacturing technical process of gel-type Technetium-99 generator, including the preparation of target containing nature MoO 3 , the target irradiation in reactor, gel preparation, gel filtration and drying, dried gel cracking, generator loading and activity calibration of generator. The performances of gel-type Technetium-99m generator, such as elution efficiency, elution profile, the pH, Mo breakthrough, Zirconium content, radiochemical purity, radionuclidic purity, sterility and pyrogencity of eluate, are also expatiated in detail. Comparing with fission-type Technetium-99m generator, the defects of gel-type Technetium-99m generator are enumerated and their overcoming solutions are recommended in this paper. (author)

  8. Numerical analysis of the performance prediction for a thermoelectric generator

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chang Nyung [Kyung Hee University, Yongin (Korea, Republic of)

    2015-09-15

    The present study develops a two-dimensional numerical code that can predict the performance of a thermoelectric generator module including a p-leg/n-leg pair and top and bottom electrodes. The present code can simulate the detailed thermoelectric phenomena including the heat flow, electric current, Joule heating, Peltier heating, and Thomson heating, together with the efficiency of the modules whose properties depend on the temperature. The present numerical code can be used for the design optimization of a thermoelectric power generator.

  9. Systems engineering approach towards performance monitoring of emergency diesel generator

    International Nuclear Information System (INIS)

    Nurhayati Ramli; Lee, Y.K.

    2013-01-01

    Full-text: Systems engineering is an interdisciplinary approach and means to enable the realization of successful systems. In this study, systems engineering approach towards the performance monitoring of Emergency Diesel Generator (EDG) is presented. Performance monitoring is part and parcel of predictive maintenance where the systems and components conditions can be detected before they result into failures. In an effort to identify the proposal for addressing performance monitoring, the EDG boundary has been defined. Based on the Probabilistic Safety Analysis (PSA) results and industry operating experiences, the most critical component is identified. This paper proposed a systems engineering concept development framework towards EDG performance monitoring. The expected output of this study is that the EDG reliability can be improved by the performance monitoring alternatives through the systems engineering concept development effort. (author)

  10. Performance evaluation of microturbine generation system for microgrid applications

    Energy Technology Data Exchange (ETDEWEB)

    Salam, A.A.; Mohamed, A.; Hannan, M.A.; Shareef, H.; Wanik, M.Z.C. [Kebangsaan Malaysia Univ., Selangor (Malaysia). Dept. of Electrical, Electronic and Systems Engineering, Faculty of Engineering and Built Environment

    2009-03-11

    A control system for microturbine generation system (MGS) units in microgrid applications was presented. A dynamic model of the microturbine and power electronics interface systems was used to determine converter control strategies for distributed generation operation. Back-to-back converters were used to interface the microturbine-based distributed generation system to the grid. The controllers were used to regulate the output voltage value at the reference bus voltage and the frequency of the whole grid. Reference values were predetermined in the control scheme in order to obtain the desired value of voltage amplitude and frequency. An investigation of system dynamics was conducted using simulations in both grid-connected and islanded modes. Results of the simulations demonstrated the ability of the MGS to improve electricity grid reliability. The model can be used to accurately simulate MGS dynamic performance for both grid- and islanded modes of operation. 10 refs., 17 figs.

  11. Studies of MHD generator performance with oxygen enriched coal combustion

    Science.gov (United States)

    Wormhoudt, J.; Yousefian, V.; Kolb, C. E.; Martinez-Sanchez, M.

    1980-07-01

    This paper presents calculations made using the Aerodyne PACKAGE (Plasma Analysis, Chemical Kinetics, and Generator Efficiency) computer code which bear on two questions which arise in connection with choices between oxygen enrichment and air preheating to attain the high combustion temperatures needed for open-cycle, coal-fired MHD power generation. The first question is which method produces the highest enthalpy extraction per unit channel length. The second is, in test facilities intended to study tradeoffs between oxygen enrichment and preheated air, can good generator performance be obtained from the same physical channel for different combustor compositions. The answer to the first question is found to depend on what combustor conditions are taken to be comparable. As for the second question, it is found that operation with channel input from off-design combustor conditions can cause serious problems, which can be partially alleviated by changing the channel load factors.

  12. Trajectory generation for two robots cooperating to perform a task

    International Nuclear Information System (INIS)

    Lewis, C.L.

    1995-01-01

    This paper formulates an algorithm for trajectory generation for two robots cooperating to perform an assembly task. Treating the two robots as a single redundant system, this paper derives two Jacobian matrices which relate the joint rates of the entire system to the relative motion of the grippers with respect to one another. The advantage of this formulation over existing methods is that a variety of secondary criteria can be conveniently satisfied using motion in the null-space of the relative Jacobian. This paper presents methods for generating dual-arm joint trajectories which perform assembly tasks while at the same time avoiding obstacles and joint limits, and also maintaining constraints on the absolute position and orientation of the end-effectors

  13. Performance of finite order distribution-generated universal portfolios

    Science.gov (United States)

    Pang, Sook Theng; Liew, How Hui; Chang, Yun Fah

    2017-04-01

    A Constant Rebalanced Portfolio (CRP) is an investment strategy which reinvests by redistributing wealth equally among a set of stocks. The empirical performance of the distribution-generated universal portfolio strategies are analysed experimentally concerning 10 higher volume stocks from different categories in Kuala Lumpur Stock Exchange. The time interval of study is from January 2000 to December 2015, which includes the credit crisis from September 2008 to March 2009. The performance of the finite-order universal portfolio strategies has been shown to be better than Constant Rebalanced Portfolio with some selected parameters of proposed universal portfolios.

  14. Entropy generation minimization: A practical approach for performance evaluation of temperature cascaded co-generation plants

    KAUST Repository

    Myat, Aung; Thu, Kyaw; Kim, Youngdeuk; Saha, Bidyut Baran; Ng, K. C.

    2012-01-01

    We present a practical tool that employs entropy generation minimization (EGM) approach for an in-depth performance evaluation of a co-generation plant with a temperature-cascaded concept. Co-generation plant produces useful effect production sequentially, i.e., (i) electricity from the micro-turbines, (ii) low pressure steam at 250 °C or about 8-10 bars, (iii) cooling capacity of 4 refrigeration tones (Rtons) and (iv) dehumidification of outdoor air for air conditioned space. The main objective is to configure the most efficient configuration of producing power and heat. We employed entropy generation minimization (EGM) which reflects to minimize the dissipative losses and maximize the cycle efficiency of the individual thermally activated systems. The minimization of dissipative losses or EGM is performed in two steps namely, (i) adjusting heat source temperatures for the heat-fired cycles and (ii) the use of Genetic Algorithm (GA), to seek out the sensitivity of heat transfer areas, flow rates of working fluids, inlet temperatures of heat sources and coolant, etc., over the anticipated range of operation to achieve maximum efficiency. With EGM equipped with GA, we verified that the local minimization of entropy generation individually at each of the heat-activated processes would lead to the maximum efficiency of the system. © 2012.

  15. Entropy generation minimization: A practical approach for performance evaluation of temperature cascaded co-generation plants

    KAUST Repository

    Myat, Aung

    2012-10-01

    We present a practical tool that employs entropy generation minimization (EGM) approach for an in-depth performance evaluation of a co-generation plant with a temperature-cascaded concept. Co-generation plant produces useful effect production sequentially, i.e., (i) electricity from the micro-turbines, (ii) low pressure steam at 250 °C or about 8-10 bars, (iii) cooling capacity of 4 refrigeration tones (Rtons) and (iv) dehumidification of outdoor air for air conditioned space. The main objective is to configure the most efficient configuration of producing power and heat. We employed entropy generation minimization (EGM) which reflects to minimize the dissipative losses and maximize the cycle efficiency of the individual thermally activated systems. The minimization of dissipative losses or EGM is performed in two steps namely, (i) adjusting heat source temperatures for the heat-fired cycles and (ii) the use of Genetic Algorithm (GA), to seek out the sensitivity of heat transfer areas, flow rates of working fluids, inlet temperatures of heat sources and coolant, etc., over the anticipated range of operation to achieve maximum efficiency. With EGM equipped with GA, we verified that the local minimization of entropy generation individually at each of the heat-activated processes would lead to the maximum efficiency of the system. © 2012.

  16. Deep learning—Accelerating Next Generation Performance Analysis Systems?

    Directory of Open Access Journals (Sweden)

    Heike Brock

    2018-02-01

    Full Text Available Deep neural network architectures show superior performance in recognition and prediction tasks of the image, speech and natural language domains. The success of such multi-layered networks encourages their implementation in further application scenarios as the retrieval of relevant motion information for performance enhancement in sports. However, to date deep learning is only seldom applied to activity recognition problems of the human motion domain. Therefore, its use for sports data analysis might remain abstract to many practitioners. This paper provides a survey on recent works in the field of high-performance motion data and examines relevant technologies for subsequent deployment in real training systems. In particular, it discusses aspects of data acquisition, processing and network modeling. Analysis suggests the advantage of deep neural networks under difficult and noisy data conditions. However, further research is necessary to confirm the benefit of deep learning for next generation performance analysis systems.

  17. A third generation of performance contracting in danish central government?

    DEFF Research Database (Denmark)

    Kristiansen, Mads Bøge

    2017-01-01

    This paper compares the content of performance contracts in Danish central government over time in order to identify whether – and if so, how – it develops. The analysis is conducted as a two-step, mixed methods study. First, a quantitative study was carried out based on a study of all performance...... contracts in Danish central government in 2002, 2006, 2009, 2012 and 2014. For each year, all performance contracts have been coded according to the number and type of targets included in them. A range of qualitative interviews was then carried out, and Ministry of Finance recommendations were consulted...... of outcomes has increased, activity-oriented targets have decreased, and targets for internal management decreased in the mid-2000s before again increasing more recently. On this basis, performance contracting in Danish central government is argued to have entered a third generation....

  18. Performance evaluation of stand alone hybrid PV-wind generator

    International Nuclear Information System (INIS)

    Nasir, M. N. M.; Saharuddin, N. Z.; Sulaima, M. F.; Jali, Mohd Hafiz; Bukhari, W. M.; Bohari, Z. H.; Yahaya, M. S.

    2015-01-01

    This paper presents the performance evaluation of standalone hybrid system on Photovoltaic (PV)-Wind generator at Faculty of Electrical Engineering (FKE), UTeM. The hybrid PV-Wind in UTeM system is combining wind turbine system with the solar system and the energy capacity of this hybrid system can generate up to charge the battery and supply the LED street lighting load. The purpose of this project is to evaluate the performance of PV-Wind hybrid generator. Solar radiation meter has been used to measure the solar radiation and anemometer has been used to measure the wind speed. The effectiveness of the PV-Wind system is based on the various data that has been collected and compared between them. The result shows that hybrid system has greater reliability. Based on the solar result, the correlation coefficient shows strong relationship between the two variables of radiation and current. The reading output current followed by fluctuate of solar radiation. However, the correlation coefficient is shows moderate relationship between the two variables of wind speed and voltage. Hence, the wind turbine system in FKE show does not operate consistently to produce energy source for this hybrid system compare to PV system. When the wind system does not fully operate due to inconsistent energy source, the other system which is PV will operate and supply the load for equilibrate the extra load demand

  19. Performance characterisation and optimisation of the HIPOS positron generator setup

    Energy Technology Data Exchange (ETDEWEB)

    Tucek, K., E-mail: kamil.tucek@ec.europa.eu [European Commission, Joint Research Centre, Institute for Energy and Transport, P.O. Box 2, NL-1755 ZG Petten (Netherlands); Zeman, A.; Daquino, G.; Debarberis, L. [European Commission, Joint Research Centre, Institute for Energy and Transport, P.O. Box 2, NL-1755 ZG Petten (Netherlands); Hogenbirk, A. [Nuclear Research and Consultancy Group (NRG), P.O. Box 25, NL-1755 ZG Petten (Netherlands)

    2012-01-01

    As part of an Exploratory Research Project at the Institute for Energy and Transport (Joint Research Centre of the European Commission), a feasibility assessment was performed for the construction and placement of a high-intensity positron facility (HIPOS) in a beam tube, HB9, at the High flux reactor (HFR) in Petten. This paper reports on the results of Monte Carlo simulations to optimise the concept of the HIPOS positron generator and to determine the performance characteristics of the chosen generator design. In the first step, a detailed model of the HFR reactor core, reflector, instrumentation and HB9 beam tube was prepared, and coupled neutron and photon transport calculations were carried out with the MCNP4C3 code to establish neutron and photon source terms on boundary surfaces of the HB9 beam tube. These sources were subsequently used with the MCNPX code to optimise the positron generator concept and geometry. The results showed that the positron beam can reach an integral intensity of 10{sup 13} e{sup +}/s before the moderation stage, easily meeting the specified target and confirming the hypothesis that very high positron yields can be obtained by using combined neutron and gamma radiation sources from a high flux reactor. Full details of the research work are reported in this study.

  20. Performance evaluation of stand alone hybrid PV-wind generator

    Science.gov (United States)

    Nasir, M. N. M.; Saharuddin, N. Z.; Sulaima, M. F.; Jali, Mohd Hafiz; Bukhari, W. M.; Bohari, Z. H.; Yahaya, M. S.

    2015-05-01

    This paper presents the performance evaluation of standalone hybrid system on Photovoltaic (PV)-Wind generator at Faculty of Electrical Engineering (FKE), UTeM. The hybrid PV-Wind in UTeM system is combining wind turbine system with the solar system and the energy capacity of this hybrid system can generate up to charge the battery and supply the LED street lighting load. The purpose of this project is to evaluate the performance of PV-Wind hybrid generator. Solar radiation meter has been used to measure the solar radiation and anemometer has been used to measure the wind speed. The effectiveness of the PV-Wind system is based on the various data that has been collected and compared between them. The result shows that hybrid system has greater reliability. Based on the solar result, the correlation coefficient shows strong relationship between the two variables of radiation and current. The reading output current followed by fluctuate of solar radiation. However, the correlation coefficient is shows moderate relationship between the two variables of wind speed and voltage. Hence, the wind turbine system in FKE show does not operate consistently to produce energy source for this hybrid system compare to PV system. When the wind system does not fully operate due to inconsistent energy source, the other system which is PV will operate and supply the load for equilibrate the extra load demand.

  1. Performance evaluation of stand alone hybrid PV-wind generator

    Energy Technology Data Exchange (ETDEWEB)

    Nasir, M. N. M.; Saharuddin, N. Z.; Sulaima, M. F.; Jali, Mohd Hafiz; Bukhari, W. M.; Bohari, Z. H. [Faculty of Electrical Engineering, Universiti Teknikal Malaysia Melaka (UTeM), Hang Tuah Jaya, 76100 Melaka (Malaysia); Yahaya, M. S. [Faculty of Engineering Technology, Universiti Teknikal Malaysia Melaka (UTeM), Hang Tuah Jaya, 76100 Melaka (Malaysia)

    2015-05-15

    This paper presents the performance evaluation of standalone hybrid system on Photovoltaic (PV)-Wind generator at Faculty of Electrical Engineering (FKE), UTeM. The hybrid PV-Wind in UTeM system is combining wind turbine system with the solar system and the energy capacity of this hybrid system can generate up to charge the battery and supply the LED street lighting load. The purpose of this project is to evaluate the performance of PV-Wind hybrid generator. Solar radiation meter has been used to measure the solar radiation and anemometer has been used to measure the wind speed. The effectiveness of the PV-Wind system is based on the various data that has been collected and compared between them. The result shows that hybrid system has greater reliability. Based on the solar result, the correlation coefficient shows strong relationship between the two variables of radiation and current. The reading output current followed by fluctuate of solar radiation. However, the correlation coefficient is shows moderate relationship between the two variables of wind speed and voltage. Hence, the wind turbine system in FKE show does not operate consistently to produce energy source for this hybrid system compare to PV system. When the wind system does not fully operate due to inconsistent energy source, the other system which is PV will operate and supply the load for equilibrate the extra load demand.

  2. A balanced strategy in managing steam generator thermal performance

    International Nuclear Information System (INIS)

    Hu, M. H.; Nelson, P. R.

    2009-01-01

    This paper presents a balanced strategy in managing thermal performance of steam generator designed to deliver rated megawatt thermal (MWt) and megawatt electric (MWe) power without loss with some amount of thermal margin. A steam generator (SG) is a boiling heat exchanger whose thermal performance may degrade because of steam pressure loss. In other words, steam pressure loss is an indicator of thermal performance degradation. Steam pressure loss is mainly a result of either 1) tube scale induced poor boiling or 2) tube plugging historically resulting from tubing corrosion, wear due to flow induced tube vibration or loose parts impact. Thermal performance degradation was historically due to tube plugging but more recently it is due to poor boiling caused by more bad than good constituents of feedwater impurities. The whole SG industry still concentrates solely on maintenance programs towards preventing causes for tube plugging and yet almost no programs on maintaining adequate boiling of fouled tubes. There can be an acceptable amount of tube scale that provides excellent boiling capacity without tubing corrosion, as operational experience has repeatedly demonstrated. Therefore, future maintenance has to come up balanced programs for allocating limited resources in both maintaining good boiling capacity and preventing tube plugging. This paper discusses also thermal performance degradation due to feedwater impurity induced blockage of tube support plate and thus subsequent water level oscillations, and how to mitigate them. This paper provides a predictive management of tube scale for maintaining adequate steam pressure and stable water level without loss in MWt/MWe or recovering from steam pressure loss or water level oscillations. This paper offers a balanced strategy in managing SG thermal performance to fulfill its mission. Such a strategy is even more important in view of the industry trend in pursuing extended power uprate as high as 20 percent

  3. Ontario Hydro Pickering Generating Station fuel handling system performance

    International Nuclear Information System (INIS)

    Underhill, H.J.

    1986-01-01

    The report briefly describes the Pickering Nuclear Generating Station (PNGS) on-power fuel handling system and refuelling cycle. Lifetime performance parameters of the fuelling system are presented, including station incapability charged to the fuel handling system, cost of operating and maintenance, dose expenditure, events causing system unavailability, maintenance and refuelling strategy. It is concluded that the 'CANDU' on-power fuelling system, by consistently contributing less than 1% to the PNGS incapability, has been credited with a 6 to 20% increase in reactor capacity factor, compared to off-power fuelling schemes. (author)

  4. Chemistry technician performance evaluation program Palo Verde Nuclear Generating Station

    International Nuclear Information System (INIS)

    Shawver, J.M.

    1992-01-01

    The Arizona Nuclear Power Project (ANPP), a three-reactor site located 50 miles west of Phoenix, Arizona, has developed and implemented a program for evaluating individual chemistry technician analytical performance on a routine basis. About 45 chemistry technicians are employed at the site, 15 at each operating unit. The technicians routinely perform trace level analyses for impurities of concern to PWRs. Each month a set of blind samples is provided by an outside vendor. The blind samples contain 16 parameters which are matrixed to approximate the PWR's primary and secondary cycles. Nine technicians receive the samples, three from each operating unit, and perform the required analyses. Acceptance criteria for successful performance on the blind parameters is based on the values found in the Institute of Nuclear Power Operations (INPO) Document 83-016, Revision 2, August 1989, Chemistry Quality Control Program. The goal of the program is to have each technician demonstrate acceptable performance on each of 16 analytical parameters. On completion of each monthly set, a summary report of all of the analytical results for the sample set is prepared. From the summary report, analytical bias can be detected, technician performance is documented, and overall laboratory performance can be evaluated. The program has been very successful at satisfying the INPO requirement that the analytical performance of each individual technician should be checked on at least a six-month frequency for all important parameters measured. This paper describes the program as implemented at the Palo Verde Nuclear Generating Station and provides a summary report and trend and bias graphs for illustrative purposes

  5. Enhanced Component Performance Study: Emergency Diesel Generators 1998-2014

    International Nuclear Information System (INIS)

    Schroeder, John Alton

    2015-01-01

    This report presents an enhanced performance evaluation of emergency diesel generators (EDGs) at U.S. commercial nuclear power plants. This report evaluates component performance over time using (1) Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES) data from 1998 through 2014 and (2) maintenance unavailability (UA) performance data from Mitigating Systems Performance Index (MSPI) Basis Document data from 2002 through 2014. The objective is to show estimates of current failure probabilities and rates related to EDGs, trend these data on an annual basis, determine if the current data are consistent with the probability distributions currently recommended for use in NRC probabilistic risk assessments, show how the reliability data differ for different EDG manufacturers and for EDGs with different ratings; and summarize the subcomponents, causes, detection methods, and recovery associated with each EDG failure mode. Engineering analyses were performed with respect to time period and failure mode without regard to the actual number of EDGs at each plant. The factors analyzed are: sub-component, failure cause, detection method, recovery, manufacturer, and EDG rating. Six trends with varying degrees of statistical significance were identified in the data.

  6. Performance characteristics of aerodynamically optimum turbines for wind energy generators

    Science.gov (United States)

    Rohrbach, C.; Worobel, R.

    1975-01-01

    This paper presents a brief discussion of the aerodynamic methodology for wind energy generator turbines, an approach to the design of aerodynamically optimum wind turbines covering a broad range of design parameters, some insight on the effect on performance of nonoptimum blade shapes which may represent lower fabrication costs, the annual wind turbine energy for a family of optimum wind turbines, and areas of needed research. On the basis of the investigation, it is concluded that optimum wind turbines show high performance over a wide range of design velocity ratios; that structural requirements impose constraints on blade geometry; that variable pitch wind turbines provide excellent power regulation and that annual energy output is insensitive to design rpm and solidity of optimum wind turbines.

  7. Coal-fired high performance power generating system. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-08-31

    As a result of the investigations carried out during Phase 1 of the Engineering Development of Coal-Fired High-Performance Power Generation Systems (Combustion 2000), the UTRC-led Combustion 2000 Team is recommending the development of an advanced high performance power generation system (HIPPS) whose high efficiency and minimal pollutant emissions will enable the US to use its abundant coal resources to satisfy current and future demand for electric power. The high efficiency of the power plant, which is the key to minimizing the environmental impact of coal, can only be achieved using a modern gas turbine system. Minimization of emissions can be achieved by combustor design, and advanced air pollution control devices. The commercial plant design described herein is a combined cycle using either a frame-type gas turbine or an intercooled aeroderivative with clean air as the working fluid. The air is heated by a coal-fired high temperature advanced furnace (HITAF). The best performance from the cycle is achieved by using a modern aeroderivative gas turbine, such as the intercooled FT4000. A simplified schematic is shown. In the UTRC HIPPS, the conversion efficiency for the heavy frame gas turbine version will be 47.4% (HHV) compared to the approximately 35% that is achieved in conventional coal-fired plants. This cycle is based on a gas turbine operating at turbine inlet temperatures approaching 2,500 F. Using an aeroderivative type gas turbine, efficiencies of over 49% could be realized in advanced cycle configuration (Humid Air Turbine, or HAT). Performance of these power plants is given in a table.

  8. Generation of artificial FASTQ files to evaluate the performance of next-generation sequencing pipelines.

    Directory of Open Access Journals (Sweden)

    Matthew Frampton

    Full Text Available Pipelines for the analysis of Next-Generation Sequencing (NGS data are generally composed of a set of different publicly available software, configured together in order to map short reads of a genome and call variants. The fidelity of pipelines is variable. We have developed ArtificialFastqGenerator, which takes a reference genome sequence as input and outputs artificial paired-end FASTQ files containing Phred quality scores. Since these artificial FASTQs are derived from the reference genome, it provides a gold-standard for read-alignment and variant-calling, thereby enabling the performance of any NGS pipeline to be evaluated. The user can customise DNA template/read length, the modelling of coverage based on GC content, whether to use real Phred base quality scores taken from existing FASTQ files, and whether to simulate sequencing errors. Detailed coverage and error summary statistics are outputted. Here we describe ArtificialFastqGenerator and illustrate its implementation in evaluating a typical bespoke NGS analysis pipeline under different experimental conditions. ArtificialFastqGenerator was released in January 2012. Source code, example files and binaries are freely available under the terms of the GNU General Public License v3.0. from https://sourceforge.net/projects/artfastqgen/.

  9. Analysis of the Dynamic Performance of Self-Excited Induction Generators Employed in Renewable Energy Generation

    Directory of Open Access Journals (Sweden)

    Mohamed E. A. Farrag

    2014-01-01

    Full Text Available Incentives, such as the Feed-in-tariff are expected to lead to continuous increase in the deployment of Small Scale Embedded Generation (SSEG in the distribution network. Self-Excited Induction Generators (SEIG represent a significant segment of potential SSEG. The quality of SEIG output voltage magnitude and frequency is investigated in this paper to support the SEIG operation for different network operating conditions. The dynamic behaviour of the SEIG resulting from disconnection, reconnection from/to the grid and potential operation in islanding mode is studied in detail. The local load and reactive power supply are the key factors that determine the SEIG performance, as they have significant influence on the voltage and frequency change after disconnection from the grid. Hence, the aim of this work is to identify the optimum combination of the reactive power supply (essential for self excitation of the SEIG and the active load (essential for balancing power generation and demand. This is required in order to support the SEIG operation after disconnection from the grid, during islanding and reconnection to the grid. The results show that the generator voltage and speed (frequency can be controlled and maintained within the statuary limits. This will enable safe disconnection and reconnection of the SEIG from/to the grid and makes it easier to operate in islanding mode.

  10. Complex rehabilitation and the clinical condition of working rheumatoid arthritis patients: does cryotherapy always overtop traditional rehabilitation?

    Science.gov (United States)

    Księżopolska-Orłowska, Krystyna; Pacholec, Anna; Jędryka-Góral, Anna; Bugajska, Joanna; Sadura-Sieklucka, Teresa; Kowalik, Katarzyna; Pawłowska-Cyprysiak, Karolina; Łastowiecka-Moras, Elżbieta

    2016-01-01

    Rehabilitation slows the progress of rheumatoid arthritis (RA) and prevents progression of disability. This study aimed to compare the impact of two rehabilitation programmes on pain, disease activity, locomotor function, global health and work ability forecast in RA patients. Sixty-four employed women aged 24-65 years participated in the study. All patients underwent individual and instrumental kinesiotherapy. Thirty-two patients underwent cryogenic chamber therapy and local cryotherapy as well as non-weight-bearing, instrumental and individual kinesiotherapy. The remaining 32 patients received traditional rehabilitation in the form of electromagnetic and instrumental therapy, individual and pool-based non-weight-bearing kinesiotherapy. Rehabilitation lasted 3 weeks. Patients were examined three times: prior to rehabilitation, after 3 weeks of therapy and 3 months after completion of rehabilitation. The following study instruments were used: to assess disease activity: DAS-28; functional impairment: HAQ-DI; pain severity: VAS; patients' overall well-being: a scale from 0 to 100 (Global Health Index); and patients' own prognosis of fitness for work: the 6th question from Work Ability Index (WAI). Statistical analysis of data was performed using the STATISTICA 8.0 package. Mixed-design two-way analysis of variance was used for hypothesis testing. All patients improved after rehabilitation. The group of patients those who underwent cryotherapy had improved DAS-28, HAQ-DI, VAS and global health scores immediately following the 3-week rehabilitation programme (p cryotherapy resulted in greater improvement in disease activity DAS-28 [F(2,105) = 5.700; p = 0.007; η(2) = 0.084] and HAQ-DI locomotor function scores [F(2,109) = 6.771; p = 0.003; η(2) = 0.098] compared to traditional rehabilitation. The impact of both forms of rehabilitation on patients' own prognosis of work ability in the next 2 years was not significant. Results of patients who underwent

  11. Thermal Model Predictions of Advanced Stirling Radioisotope Generator Performance

    Science.gov (United States)

    Wang, Xiao-Yen J.; Fabanich, William Anthony; Schmitz, Paul C.

    2014-01-01

    This paper presents recent thermal model results of the Advanced Stirling Radioisotope Generator (ASRG). The three-dimensional (3D) ASRG thermal power model was built using the Thermal Desktop(trademark) thermal analyzer. The model was correlated with ASRG engineering unit test data and ASRG flight unit predictions from Lockheed Martin's (LM's) I-deas(trademark) TMG thermal model. The auxiliary cooling system (ACS) of the ASRG is also included in the ASRG thermal model. The ACS is designed to remove waste heat from the ASRG so that it can be used to heat spacecraft components. The performance of the ACS is reported under nominal conditions and during a Venus flyby scenario. The results for the nominal case are validated with data from Lockheed Martin. Transient thermal analysis results of ASRG for a Venus flyby with a representative trajectory are also presented. In addition, model results of an ASRG mounted on a Cassini-like spacecraft with a sunshade are presented to show a way to mitigate the high temperatures of a Venus flyby. It was predicted that the sunshade can lower the temperature of the ASRG alternator by 20 C for the representative Venus flyby trajectory. The 3D model also was modified to predict generator performance after a single Advanced Stirling Convertor failure. The geometry of the Microtherm HT insulation block on the outboard side was modified to match deformation and shrinkage observed during testing of a prototypic ASRG test fixture by LM. Test conditions and test data were used to correlate the model by adjusting the thermal conductivity of the deformed insulation to match the post-heat-dump steady state temperatures. Results for these conditions showed that the performance of the still-functioning inboard ACS was unaffected.

  12. WWER Steam Generators Tubing Performance and Aging Management

    International Nuclear Information System (INIS)

    Trunov, Nikolay B.; Davidenko, Stanislav E.; Grigoriev, Vladimir A.; Popadchuk, Valery S.; Brykov, Sergery I.; Karzov, Georgy P.

    2006-01-01

    At WWER NPPs the horizontal steam generators (SGs), are used that differ in design concept from vertical SGs mostly used at western NPPs. Reliable operation of SG heat-exchanging tubes is the crucial worldwide problem for NPP of various types. According to the operation feedback the water chemistry is the governing factor affecting operability of SG tubing. The secondary side corrosion is considered to be the main mechanism of SG heat-exchanging tubes damage at WWER plants. To make the assessment of the tubing integrity the combination of pressure tests and eddy-current tests is used. Assessment of the tubing performance is an important part of SG life extension practice. The given paper deals with the description of the tube testing strategy and the approach to tube integrity assessment based on deterministic and probabilistic methods of fracture mechanics. Requirements for eddy-current test are given as well. Practice of condition monitoring and implementing the database on steam generators operation are presented. The approach to tubes plugging criteria is described. The research activities on corrosion mechanism studies and residual lifetime evaluation are mentioned. (authors)

  13. High performance current generator with one-picoampere resolution

    International Nuclear Information System (INIS)

    Grillo, L.; Manfredi, P.F.; Marchesini, R.

    1975-01-01

    A high-performance current generator for the picoampere region is presented. Although it was primarily developed as a part of an automatic test system to calibrate charge integrators for accelerating machines. It can suit a wide range of applications. It consists basically of a positive feedback loop of controlled gain which includes a varactor bridge operational amplifier. The essential features of the instrument are a 1 pA resolution and a 10 15 Ω output impedance. The output is guarded and floating between - 120 V and + 120 V, and the voltage across the external loads is measured without affecting the delivered current by a digital panel meter on the front panel. The unit can therefore operate as a high-accuracy dc impedance meter. (Auth.)

  14. Prediction of the Effect of Vortex Generators on Airfoil Performance

    International Nuclear Information System (INIS)

    Sørensen, Niels N; Zahle, F; Bak, C; Vronsky, T

    2014-01-01

    Vortex Generators (VGs) are widely used by the wind turbine industry, to control the flow over blade sections. The present work describes a computational fluid dynamic procedure that can handle a geometrical resolved VG on an airfoil section. After describing the method, it is applied to two different airfoils at a Reynolds number of 3 million, the FFA- W3-301 and FFA-W3-360, respectively. The computations are compared with wind tunnel measurements from the Stuttgart Laminar Wind Tunnel with respect to lift and drag variation as function of angle of attack. Even though the method does not exactly capture the measured performance, it can be used to compare different VG setups qualitatively with respect to chord- wise position, inter and intra-spacing and inclination of the VGs already in the design phase

  15. Finite element analysis and performance study of switched reluctance generator

    Science.gov (United States)

    Zhang, Qianhan; Guo, Yingjun; Xu, Qi; Yu, Xiaoying; Guo, Yajie

    2017-03-01

    Analyses a three-phase 12/8 switched reluctance generator (SRG) which is based on its structure and performance principle. The initial size data were calculated by MathCAD, and the simulation model was set up in the ANSOFT software environment with the maximum efficiency and the maximum output power as the main reference parameters. The outer diameter of the stator and the inner diameter of the rotor were parameterized. The static magnetic field distribution, magnetic flux, magnetic energy, torque, inductance characteristics, back electromotive force and phase current waveform of SRG is obtained by analyzing the static magnetic field and the steady state motion of two-dimensional transient magnetic field in ANSOFT environment. Finally, the experimental data of the prototype are compared with the simulation results, which provide a reliable basis for the design and research of SRG wind turbine system.

  16. Performance of the Fitch generator in a nanosecond electron accelerator

    International Nuclear Information System (INIS)

    Chernyj, V.V.

    1976-01-01

    The operation of the Fitch generator in the nanosecond electron accelerator is discussed. The operating principle of the generator is based on the inversion of the voltage at the storage capacitances. Only one discharger is employed in the discharge circuit of the generator which provides for decreasing the generator impedance to 24 Ohms. The maximum accelerating voltage equals 0.6 MV

  17. Improvement of sludge removal performance for steam generators

    International Nuclear Information System (INIS)

    Nishida, K.; Sakai, K.; Ito, H.; Tanahashi, A.; Nakao, F.

    2002-01-01

    Scale, mainly consisting of magnetite, flows on the secondary side of steam generators (SGs), causing the formation of concentrations of impurities on the tubesheet (TS), increasing the fouling of tube heat transfer, and blocking the broached egg crates (BEC) on the tube support plates (TSP). Accumulation of sludge on the tubesheet forms environment in which impurities are highly concentrated on the tubes. And we have experienced tube degradation, in the past, from the concentration of impurities. In Japan, the first tubesheet sludge lancing, via water jets, was done at the Mihama-2 plant in 1975. And that is why this pile sludge becomes hard depending on time, removal made an effort toward removal with CECIL* (in bundle cleaning system) us very difficulty. However, sludge remained in localized areas and it had possibility of concentration. So that we improve the CECIL for the purpose of removing it, and we improved removal performance of the device. In addition to the improvement of CECIL, we install a sludge collector in order to decrease accumulation of sludge on the tubesheet. This paper introduces these improvements in sludge removal performance. (authors)

  18. Performance analysis of next-generation lunar laser retroreflectors

    Science.gov (United States)

    Ciocci, Emanuele; Martini, Manuele; Contessa, Stefania; Porcelli, Luca; Mastrofini, Marco; Currie, Douglas; Delle Monache, Giovanni; Dell'Agnello, Simone

    2017-09-01

    Starting from 1969, Lunar Laser Ranging (LLR) to the Apollo and Lunokhod Cube Corner Retroreflectors (CCRs) provided several tests of General Relativity (GR). When deployed, the Apollo/Lunokhod CCRs design contributed only a negligible fraction of the ranging error budget. Today the improvement over the years in the laser ground stations makes the lunar libration contribution relevant. So the libration now dominates the error budget limiting the precision of the experimental tests of gravitational theories. The MoonLIGHT-2 project (Moon Laser Instrumentation for General relativity High-accuracy Tests - Phase 2) is a next-generation LLR payload developed by the Satellite/lunar/GNSS laser ranging/altimetry and Cube/microsat Characterization Facilities Laboratory (SCF _ Lab) at the INFN-LNF in collaboration with the University of Maryland. With its unique design consisting of a single large CCR unaffected by librations, MoonLIGHT-2 can significantly reduce error contribution of the reflectors to the measurement of the lunar geodetic precession and other GR tests compared to Apollo/Lunokhod CCRs. This paper treats only this specific next-generation lunar laser retroreflector (MoonLIGHT-2) and it is by no means intended to address other contributions to the global LLR error budget. MoonLIGHT-2 is approved to be launched with the Moon Express 1(MEX-1) mission and will be deployed on the Moon surface in 2018. To validate/optimize MoonLIGHT-2, the SCF _ Lab is carrying out a unique experimental test called SCF-Test: the concurrent measurement of the optical Far Field Diffraction Pattern (FFDP) and the temperature distribution of the CCR under thermal conditions produced with a close-match solar simulator and simulated space environment. The focus of this paper is to describe the SCF _ Lab specialized characterization of the performance of our next-generation LLR payload. While this payload will improve the contribution of the error budget of the space segment (MoonLIGHT-2

  19. Utilization of oil wells for electricity generation: Performance and economics

    International Nuclear Information System (INIS)

    Kharseh, Mohamad; Al-Khawaja, Mohammed; Hassani, Ferri

    2015-01-01

    There is a general agreement that the climate change, which is the most important challenge facing humanity, is anthropogenic and attributed to fossil fuel consumption. Therefore, deploying more renewable energy resources is an urgent issue to be addressed. Geothermal refers to existing heat energy in deep rock and sedimentary basins. Traditionally, geothermal energy has been exploited in places with plentiful hot water at relatively shallow depth. Unfortunately, the high exploration and drilling costs of boreholes is the main barrier to the commerciality of geothermal worldwide. In oil producing countries, such problems can be overcome by utilizing oil or gas wells. The current study presents thermodynamic and economic analyses of a binary geothermal power generation system for commercial electricity generation. Two different source temperatures (100 and 120 °C) and constant sink temperature (29 °C) were considered. The optimal working fluid and optimal design that improve the performance of the plant are determined. For the current costs in Qatar, the economical analysis of 5 MW geothermal plant shows that the levelized cost of electricity for the plant varies from 5.6 to 5.2 ¢/kW. Whereas, the payback period of such plants lies between 5.8 and 4.8 years. - Highlights: • Utilizing oil well makes geothermal plant competitive with other resources. • R32 seems to be the best working fluid. • The levelized cost of electricity for geothermal plant is less than 5.6 ¢/kWh. • The payback time of geothermal plant is less than 6 years.

  20. URBAN MODELLING PERFORMANCE OF NEXT GENERATION SAR MISSIONS

    Directory of Open Access Journals (Sweden)

    U. G. Sefercik

    2017-09-01

    Full Text Available In synthetic aperture radar (SAR technology, urban mapping and modelling have become possible with revolutionary missions TerraSAR-X (TSX and Cosmo-SkyMed (CSK since 2007. These satellites offer 1m spatial resolution in high-resolution spotlight imaging mode and capable for high quality digital surface model (DSM acquisition for urban areas utilizing interferometric SAR (InSAR technology. With the advantage of independent generation from seasonal weather conditions, TSX and CSK DSMs are much in demand by scientific users. The performance of SAR DSMs is influenced by the distortions such as layover, foreshortening, shadow and double-bounce depend up on imaging geometry. In this study, the potential of DSMs derived from convenient 1m high-resolution spotlight (HS InSAR pairs of CSK and TSX is validated by model-to-model absolute and relative accuracy estimations in an urban area. For the verification, an airborne laser scanning (ALS DSM of the study area was used as the reference model. Results demonstrated that TSX and CSK urban DSMs are compatible in open, built-up and forest land forms with the absolute accuracy of 8–10 m. The relative accuracies based on the coherence of neighbouring pixels are superior to absolute accuracies both for CSK and TSX.

  1. Influence of slag-seed interaction on MHD generator performance

    International Nuclear Information System (INIS)

    Luongo, C.A.; Kruger, C.M.

    1984-01-01

    An overview of past work in the field of slag/seed interaction is presented. The ideal solution model for the slag and its failure to lead to accurate predictions are discussed. The non-ideal solution model is introduced. Data on potassium vapor pressure over slags taken at the National Bureau of Standards and Montana State University were compiled and compared. Large disagreement between these sources was observed. The shortcomings of the complete thermodynamic equilibrium models led to over predictions in the fraction of seed lost to the slag. A model including non-equilibrium effects is introduced. The heat/mass transfer analogy is invoked to calculate the mass transfer rate of potassium towards the slag. Using typical conditions for a large MHD generator, an integral method is used to evaluate the potassium concentration boundary layer thickness. The calculations are performed with the slag runoff (ash rejection) as a parameter. The increase in boundary layer resistance due to potassium depletion is calculated

  2. Next Generation Life Support: High Performance EVA Glove

    Science.gov (United States)

    Walsh, Sarah K.

    2015-01-01

    The objectives of the High Performance EVA Glove task are to develop advanced EVA gloves for future human space exploration missions and generate corresponding standards by which progress may be quantitatively assessed. New technologies and manufacturing techniques will be incorporated into the new gloves to address finger and hand mobility, injury reduction and durability in nonpristine environments. Three prototypes will be developed, each focusing on different technological advances. A robotic assist glove will integrate a powered grasping system into the current EVA glove design to reduce astronaut hand fatigue and hand injuries. A mechanical counter pressure (MCP) glove will be developed to further explore the potential of MCP technology and assess its capability for countering the effects of vacuum or low pressure environments on the body by using compression fabrics or materials to apply the necessary pressure. A gas pressurized glove, incorporating new technologies, will be the most flight-like of the three prototypes. Advancements include the development and integration of aerogel insulation, damage sensing components, dust-repellant coatings, and dust tolerant bearings.

  3. Study on performance of blended fuel PPO - Diesel at generator

    Science.gov (United States)

    Prasetyo, Joni; Prasetyo, Dwi Husodo; Murti, S. D. Sumbogo; Adiarso, Priyanto, Unggul

    2018-02-01

    Bio-energy is renewable energy made from plant. Biomass-based energy sources are potentially CO2 neutral and recycle the same carbon atoms. In order to reduce pollution caused by fossil fuel combustion either for mechanical or electrical energy generation, the performance characteristic of purified palm oil blends are analyzed at various ratios. Bio-energy, Pure Plant Oil, represent a sustainable solution.A generator has been modified due to adapt the viscosity ofblended fuel, PPO - diesel, by pre-heating. Several PPO - diesel composition and injection timing were tested in order to investigate the characteristic of mixed fuel with and without pre-heating. The term biofuel refers to liquid or gaseous fuels for the internal combustion engines that are predominantly produced fro m biomass. Surprising result showed that BSFC of blended PPO - diesel was more efficient when injection timing set more than 15° BTDC. The mixed fuel produced power with less mixed fuel even though the calorie content of diesel is higher than PPO. The most efficient was 20% PPO in diesel with BSFC 296 gr fuel / kwh rather than 100% diesel with BSFC 309 gr fuel / kwh at the same injection timing 18° BTDC with pre-heating. The improvement of BSFC is caused by heating up of mixed fuel which it added calorie in the mixed fuel. Therefore, the heating up of blended PPO - diesel is not only to adapt the viscosity but also improving the efficiency of fuel usage representing by lower BSFC. In addition, torque of the 20% PPO was also as smooth as 100% diesel representing by almost the same torqueat injection timing 15° BTDC. The AIP Proceedings article template has many predefined paragraph styles for you to use/apply as you write your paper. To format your abstract, use the Microsoft Word template style: Abstract. Each paper must include an abstract. Begin the abstract with the word "Abstract" followed by a period in bold font, and then continue with a normal 9 point font.

  4. Design and Performance of 20 Watts Portable Solar Generator

    International Nuclear Information System (INIS)

    Majid, Z A Abdul; Hazali, N; Hanafiah, M A K M; Abdullah, A A; Ismail, A F; Ruslan, M H; Sopian, K; Azmi, M S Mohd

    2012-01-01

    A new portable solar generator has been developed to generate electricity. It has the potential to replace petrol generator, widely used by peddlers at night markets (pasar malam). Conventional generators are heavy, oily, have high maintenance and use fossil fuel to generate electricity. The solar generator can generate 20 Watts of electricity. This amount of power can supply up to 96 hours of electricity for the purpose of lighting and running small electrical appliances. The power output is (alternating current) AC current using 150 Watts inverter with 200 Watts surge, suitable for all commercial single phase electric appliances. Solar charge controller is used to maximize the charging rate and to protect the battery. The system has low maintenance whereby the batteries need to be changed every three to four years, depending on the usage. The main concepts of portable solar generator are to reduce installation cost and to introduce a compact design of an optimal energy sizing system. The materials used to develop the solar generator can be easily obtained from local markets, thus reducing the cost of developing the system and making it suitable for commercialization.

  5. Coal-fired high performance power generating system

    Energy Technology Data Exchange (ETDEWEB)

    1992-07-01

    The goals of the program are to develop a coal-fired high performance power generation system (HIPPS) by the year 2000 that is capable of > 47% thermal efficiency; NO[sub x] SO [sub x] and Particulates < 25% NSPS; Cost of electricity 10% lower; coal > 65% of heat input and all solid wastes benign. In order to achieve these goals our team has outlined a research plan based on an optimized analysis of a 250 MW[sub e] combined cycle system applicable to both frame type and aeroderivative gas turbines. Under the constraints of the cycle analysis we have designed a high temperature advanced furnace (HITAF) which integrates several combustor and air heater designs with appropriate ash management procedures. Most of this report discusses the details of work on these components, and the R D Plan for future work. The discussion of the combustor designs illustrates how detailed modeling can be an effective tool to estimate NO[sub x] production, minimum burnout lengths, combustion temperatures and even particulate impact on the combustor walls. When our model is applied to the long flame concept it indicates that fuel bound nitrogen will limit the range of coals that can use this approach. For high nitrogen coals a rapid mixing, rich-lean, deep staging combustor will be necessary. The air heater design has evolved into two segments: a convective heat exchanger downstream of the combustion process; a radiant panel heat exchanger, located in the combustor walls; The relative amount of heat transferred either radiatively or convectively will depend on the combustor type and the ash properties.

  6. Generating performance portable geoscientific simulation code with Firedrake (Invited)

    Science.gov (United States)

    Ham, D. A.; Bercea, G.; Cotter, C. J.; Kelly, P. H.; Loriant, N.; Luporini, F.; McRae, A. T.; Mitchell, L.; Rathgeber, F.

    2013-12-01

    , can be written as short C kernels operating locally on the underlying mesh, with no explicit parallelism. The executable code is then generated in C, CUDA or OpenCL and executed in parallel on the target architecture. The system also offers features of special relevance to the geosciences. In particular, the large scale separation between the vertical and horizontal directions in many geoscientific processes can be exploited to offer the flexibility of unstructured meshes in the horizontal direction, without the performance penalty usually associated with those methods.

  7. On the performance of a calibrated nanoparticle generator

    International Nuclear Information System (INIS)

    Backman, Ulrika; Lyyraenen, Jussi; Tapper, Unto; Auvinen, Ari; Jokiniemi, Jorma

    2009-01-01

    There is a need for nanoparticle generators with well characterised properties in many fields. For instance the calibration of measurement instruments can be done in place and the downtime for the instrument hence decreased. Also in nanoparticle toxicity experiments it is very important to have a well characterised particle source. The aim of this study was to develop a calibrated nanoparticle generator with stable particle production. The number concentration should be regulated over many orders of magnitude and the particle size should also be adjustable. In this paper the design of the nanoparticle generator and the properties of the produced nanoparticles at one furnace temperature are presented.

  8. UAS Demand Generation and Airspace Performance Impact Prediction, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — IAI and its academic partner propose to develop technology that will generate credible future demand for UAS vehicles given proposed UAS missions. The technology...

  9. Impact of Converter Interfaced Generation and Load on Grid Performance

    Science.gov (United States)

    Ramasubramanian, Deepak

    Alternate sources of energy such as wind, solar photovoltaic and fuel cells are coupled to the power grid with the help of solid state converters. Continued deregulation of the power sector coupled with favorable government incentives has resulted in the rapid growth of renewable energy sources connected to the distribution system at a voltage level of 34.5kV or below. Of late, many utilities are also investing in these alternate sources of energy with the point of interconnection with the power grid being at the transmission level. These converter interfaced generation along with their associated control have the ability to provide the advantage of fast control of frequency, voltage, active, and reactive power. However, their ability to provide stability in a large system is yet to be investigated in detail. This is the primary objective of this research. In the future, along with an increase in the percentage of converter interfaced renewable energy sources connected to the transmission network, there exists a possibility of even connecting synchronous machines to the grid through converters. Thus, all sources of energy can be expected to be coupled to the grid through converters. The control and operation of such a grid will be unlike anything that has been encountered till now. In this dissertation, the operation and behavior of such a grid will be investigated. The first step in such an analysis will be to build an accurate and simple mathematical model to represent the corresponding components in commercial software. Once this bridge has been crossed, conventional machines will be replaced with their solid state interfaced counterparts in a phased manner. At each stage, attention will be devoted to the control of these sources and also on the stability performance of the large power system. This dissertation addresses various concerns regarding the control and operation of a futuristic power grid. In addition, this dissertation also aims to address the issue

  10. Radial-arrayed rotary electrification for high performance triboelectric generator.

    Science.gov (United States)

    Zhu, Guang; Chen, Jun; Zhang, Tiejun; Jing, Qingshen; Wang, Zhong Lin

    2014-03-04

    Harvesting mechanical energy is an important route in obtaining cost-effective, clean and sustainable electric energy. Here we report a two-dimensional planar-structured triboelectric generator on the basis of contact electrification. The radial arrays of micro-sized sectors on the contact surfaces enable a high output power of 1.5 W (area power density of 19 mW cm(-2)) at an efficiency of 24%. The triboelectric generator can effectively harness various ambient motions, including light wind, tap water flow and normal body movement. Through a power management circuit, a triboelectric-generator-based power-supplying system can provide a constant direct-current source for sustainably driving and charging commercial electronics, immediately demonstrating the feasibility of the triboelectric generator as a practical power source. Given exceptional power density, extremely low cost and unique applicability resulting from distinctive mechanism and structure, the triboelectric generator can be applied not only to self-powered electronics but also possibly to power generation at a large scale.

  11. Next-Generation Performance-Based Regulation: Emphasizing Utility Performance to Unleash Power Sector Innovation

    Energy Technology Data Exchange (ETDEWEB)

    Logan, Jeffrey S [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Zinaman, Owen R [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Littell, David [Regulatory Assistance Project (RAP), Montpelier, VT (United States); Kadoch, Camille [Regulatory Assistance Project (RAP), Montpelier, VT (United States); Baker, Phil [Regulatory Assistance Project (RAP), Montpelier, VT (United States); Bharvirkar, Ranjit [Regulatory Assistance Project (RAP), Montpelier, VT (United States); Dupuy, Max [Regulatory Assistance Project (RAP), Montpelier, VT (United States); Hausauer, Brenda [Regulatory Assistance Project (RAP), Montpelier, VT (United States); Linvill, Carl [Regulatory Assistance Project (RAP), Montpelier, VT (United States); Migden-Ostrander, Janine [Regulatory Assistance Project (RAP), Montpelier, VT (United States); Rosenow, Jan [Regulatory Assistance Project; Xuan, Wang [Regulatory Assistance Project

    2017-09-12

    Performance-based regulation (PBR) enables regulators to reform hundred-year-old regulatory structures to unleash innovations within 21st century power systems. An old regulatory paradigm built to ensure safe and reliable electricity at reasonable prices from capital-intensive electricity monopolies is now adjusting to a new century of disruptive technological advances that change the way utilities make money and what value customers expect from their own electricity company. Advanced technologies are driving change in power sectors around the globe. Innovative technologies are transforming the way electricity is generated, delivered, and consumed. These emerging technology drivers include renewable generation, distributed energy resources such as distributed generation and energy storage, demand-side management measures such as demand-response, electric vehicles, and smart grid technologies and energy efficiency (EE). PBR enables regulators to recognize the value that electric utilities bring to customers by enabling these advanced technologies and integrating smart solutions into the utility grid and utility operations. These changes in the electric energy system and customer capacities means that there is an increasing interest in motivating regulated entities in other areas beyond traditional cost-of-service performance regulation. This report addresses best practices gleaned from more than two decades of PBR in practice, and analyzes how those best practices and lessons can be used to design innovative PBR programs. Readers looking for an introduction to PBR may want to focus on Chapters 1-5. Chapters 6 and 7 contain more detail for those interested in the intricate workings of PBR or particularly innovative PBR.

  12. Functional performance of the helical coil steam generator, Consolidated Nuclear Steam Generator (CNSG) IV system. Executive summary report

    International Nuclear Information System (INIS)

    Watson, G.B.

    1975-10-01

    The objective of this project was to study the functional performance of the CNSG - IV helical steam generator to demonstrate that the generator meets steady-state and transient thermal-hydraulic performance specifications and that secondary flow instability will not be a problem. Economic success of the CNSG concepts depends to a great extent on minimizing the size of the steam generator and the reactor vessel for ship installation. Also, for marine application the system must meet stringent specifications for operating stability, transient response, and control. The full-size two-tube experimental unit differed from the CNSG only in the number of tubes and the mode of primary flow. In general, the functional performance test demonstrated that the helical steam generator concept will exceed the specified superheat of 35F at 100% load. The experimental measured superheat at comparable operating conditions was 95F. Testing also revealed that available computer codes accurately predict trends and overall performance characteristics

  13. Steam generators: improvement of separator/dryer performance

    International Nuclear Information System (INIS)

    Holcblat, A.

    1985-10-01

    The first generation of steam generators built in France (model 51) experienced some moisture problems. As early as 1976, a large-scale development program was undertaken by Framatome, in collaboration with the French Commissariat a l'Energie Atomique and Electricite de France, to enhance design of SG separation equipment. The goal of this program was to enhance equipment operating efficiency by improving our understanding of separation phenomena. This paper presents an overview of the design and testing effort engaged within the framework of the separator development program, along with a summary of program results and forthcoming developments

  14. Effect of inflow discharges on the development of matric suction and volumetric water content for dike during overtopping tests

    Science.gov (United States)

    Hassan, Marwan A.; Ismail, Mohd A. M.

    2017-10-01

    The point of this review is to depict the impact of various inflow discharge rate releases on the instruments of matric suction and volumetric water content during an experimental test of spatial overtopping failure at school of civil engineering in universiti Sains of Malaysia. A dry sand dike was conducted inside small flume channel with twelve sensors of tensiometer and Time-Domain Reflectometer (TDR). Instruments are installed in the soil at different locations in downstream and upstream slopes of the dike for measuring the response of matric suction and volumetric water content, respectively. Two values of inflow discharge rates of 30 and 40 L/min are utilized as a part of these experiments to simulate the effectiveness of water reservoirs in erosion mechanism. The outcomes demonstrate that the matric suction and volumetric water content are decreased and increased, respectively for both inflow discharges. The higher inflow discharges accelerate the saturation of dike soil and the erosion process faster than that for the lower inflow discharges.

  15. Arbitrary waveform generator to improve laser diode driver performance

    Science.gov (United States)

    Fulkerson, Jr, Edward Steven

    2015-11-03

    An arbitrary waveform generator modifies the input signal to a laser diode driver circuit in order to reduce the overshoot/undershoot and provide a "flat-top" signal to the laser diode driver circuit. The input signal is modified based on the original received signal and the feedback from the laser diode by measuring the actual current flowing in the laser diode after the original signal is applied to the laser diode.

  16. Individualized Next-Generation Biomathematical Modeling of Fatigue and Performance

    National Research Council Canada - National Science Library

    Van Dongen, Hans P

    2006-01-01

    .... This project employed a cutting-edge technique called Bayesian forecasting to develop a novel biomathematical performance model to predict responses to sleep loss and circadian displacement for individual subjects...

  17. Prediction of the Effect of Vortex Generators on Airfoil Performance

    DEFF Research Database (Denmark)

    Sørensen, Niels N.; Zahle, Frederik; Bak, Christian

    2014-01-01

    Vortex Generators (VGs) are widely used by the wind turbine industry, to control the flow over blade sections. The present work describes a computational fluid dynamic procedure that can handle a geometrical resolved VG on an airfoil section. After describing the method, it is applied to two...... different airfoils at a Reynolds number of 3 million, the FFA- W3-301 and FFA-W3-360, respectively. The computations are compared with wind tunnel measurements from the Stuttgart Laminar Wind Tunnel with respect to lift and drag variation as function of angle of attack. Even though the method does...

  18. Experimental studies of PWR vertical steam generator performance

    International Nuclear Information System (INIS)

    Ding Xunshen

    1998-06-01

    The characteristics of heat transfer, natural circulation and moisture separation equipment with a vertical steam generator model are tested on a high-temperature and high-pressure test facility. The primary loop pipe is made of low alloy steel. the primary water at 10.13 MPa is driven by two centrifugal pumps. Boiler is designed to elevate the primary water temperature by 60 degree C at a flow rate of 65 t/h. The test model can produce a maximum steam flow of 8 t/h; 240 stainless steel U tubes are invert connected with the tubesheet, the tube dimensions are φ15 mm x 1.5 mm. The model has a height of 5.789 m. Heat transfer characteristics experiment is obtained: The steam generator thermal design can neglect the existence of preheating region, considering the saturated boiling takes place over all the tube surface. This does not exactly reflect the actual heat transfer coefficient and temperature difference. But, the product of two parameters is lower for design than for experiment so that heat transfer coefficient and temperature difference combine to result in a larger heat transfer area for design than for experiment. Moisture separator is a swirl vane separator. Dryer is a single circle of vertical chevron plate separator. Test results indicate the separation efficiency of the moisture separator and dryer is very satisfactory and the exit moisture is much better than 0.25% (the required content)

  19. Computer–aided analysis of the performance of diesel generator ...

    African Journals Online (AJOL)

    The average monthly /yearly down time over a period of years can be deduced. Results of the analysis of some water pumping stations are presented. The software is user-friendly and is designed to assist technical and managerial staff in assessing the performance of water pumping stations. [Global Jnl Engineering Res.

  20. Design Methodology and Performance Evaluation of New Generation Sounding Rockets

    Directory of Open Access Journals (Sweden)

    Marco Pallone

    2018-01-01

    Full Text Available Sounding rockets are currently deployed for the purpose of providing experimental data of the upper atmosphere, as well as for microgravity experiments. This work provides a methodology in order to design, model, and evaluate the performance of new sounding rockets. A general configuration composed of a rocket with four canards and four tail wings is sized and optimized, assuming different payload masses and microgravity durations. The aerodynamic forces are modeled with high fidelity using the interpolation of available data. Three different guidance algorithms are used for the trajectory integration: constant attitude, near radial, and sun-pointing. The sun-pointing guidance is used to obtain the best microgravity performance while maintaining a specified attitude with respect to the sun, allowing for experiments which are temperature sensitive. Near radial guidance has instead the main purpose of reaching high altitudes, thus maximizing the microgravity duration. The results prove that the methodology at hand is straightforward to implement and capable of providing satisfactory performance in term of microgravity duration.

  1. Optimal setpoint generation for improved fuel temperature performance

    International Nuclear Information System (INIS)

    Johns, R.M.; Edwards, R.M.

    1995-01-01

    Nuclear power plant systems feature a high degree of non-linearity and high noise level, and the performance of conventional control systems may degrade when power plants operate under a wide range of conditions, such as startup, test, shutdown, etc. The conventional control system is not intended for nuclear power plant full-range operation. This is the reason that, at present, nuclear power plants rely on manual operations for most wide-range control and only use automatic control around nominal conditions. The availability of new powerful control techniques and mathematical tools has motivated an expanding research effort toward the development of the advanced hybrid feedforward-feedback control system. The planned command input is based on the analysis of a system model in some form in order to improve the performance of the overall system. The use of a feedforward optimal controller to improve the fuel temperature response to a step change in desired reactor power is being demonstrated. The Penn State TRIGA reactor is used as the basis of the reactor model so that validation of the controller may be shown

  2. High Performance Fuel Desing for Next Generation Pressurized Water Reactors

    International Nuclear Information System (INIS)

    Mujid S. Kazimi; Pavel Hejzlar

    2006-01-01

    The use of internally and externally cooled annular fuel rods for high power density Pressurized Water Reactors is assessed. The assessment included steady state and transient thermal conditions, neutronic and fuel management requirements, mechanical vibration issues, fuel performance issues, fuel fabrication methods and economic assessment. The investigation was conducted by a team from MIT, Westinghouse, Gamma Engineering, Framatome ANP, and AECL. The analyses led to the conclusion that raising the power density by 50% may be possible with this advanced fuel. Even at the 150% power level, the fuel temperature would be a few hundred degrees lower than the current fuel temperature. Significant economic and safety advantages can be obtained by using this fuel in new reactors. Switching to this type of fuel for existing reactors would yield safety advantages, but the economic return is dependent on the duration of plant shutdown to accommodate higher power production. The main feasibility issue for the high power performance appears to be the potential for uneven splitting of heat flux between the inner and outer fuel surfaces due to premature closure of the outer fuel-cladding gap. This could be overcome by using a very narrow gap for the inner fuel surface and/or the spraying of a crushable zirconium oxide film at the fuel pellet outer surface. An alternative fuel manufacturing approach using vobropacking was also investigated but appears to yield lower than desirable fuel density

  3. High Performance Fuel Desing for Next Generation Pressurized Water Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Mujid S. Kazimi; Pavel Hejzlar

    2006-01-31

    The use of internally and externally cooled annular fule rods for high power density Pressurized Water Reactors is assessed. The assessment included steady state and transient thermal conditions, neutronic and fuel management requirements, mechanical vibration issues, fuel performance issues, fuel fabrication methods and econmic assessment. The investigation was donducted by a team from MIT, Westinghouse, Gamma Engineering, Framatome ANP, and AECL. The analyses led to the conclusion that raising the power density by 50% may be possible with this advanced fuel. Even at the 150% power level, the fuel temperature would be a few hundred degrees lower than the current fuel temperatre. Significant economic and safety advantages can be obtained by using this fuel in new reactors. Switching to this type of fuel for existing reactors would yield safety advantages, but the economic return is dependent on the duration of plant shutdown to accommodate higher power production. The main feasiblity issue for the high power performance appears to be the potential for uneven splitting of heat flux between the inner and outer fuel surfaces due to premature closure of the outer fuel-cladding gap. This could be overcome by using a very narrow gap for the inner fuel surface and/or the spraying of a crushable zirconium oxide film at the fuel pellet outer surface. An alternative fuel manufacturing approach using vobropacking was also investigated but appears to yield lower than desirable fuel density.

  4. Failure of Grass Covered Flood Defences with Roads on Top Due to Wave Overtopping: A Probabilistic Assessment Method

    Directory of Open Access Journals (Sweden)

    Juan P. Aguilar-López

    2018-06-01

    Full Text Available Hard structures, i.e., roads, are commonly found over flood defences, such as dikes, in order to ensure access and connectivity between flood protected areas. Several climate change future scenario studies have concluded that flood defences will be required to withstand more severe storms than the ones used for their original design. Therefore, this paper presents a probabilistic methodology to assess the effect of a road on top of a dike: it gives the failure probability of the grass cover due to wave overtopping over a wide range of design storms. The methodology was developed by building two different dike configurations in computational fluid dynamics Navier–Stokes solution software; one with a road on top and one without a road. Both models were validated with experimental data collected from field-scale experiments. Later, both models were used to produce data sets for training simpler and faster emulators. These emulators were coupled to a simplified erosion model which allowed testing storm scenarios which resulted in local scouring conditioned statistical failure probabilities. From these results it was estimated that the dike with a road has higher probabilities (5 × 10−5 > Pf >1 × 10−4 of failure than a dike without a road (Pf < 1 × 10−6 if realistic grass quality spatial distributions were assumed. The coupled emulator-erosion model was able to yield realistic probabilities, given all the uncertainties in the modelling process and it seems to be a promising tool for quantifying grass cover erosion failure.

  5. A new generation of high performance engines for spacecraft propulsion

    Science.gov (United States)

    Rosenberg, Sanders D.; Schoenman, Leonard

    1991-01-01

    Experimental data validating advanced engine designs at three thrust levels (5, 15, and 100 lbF) is presented. All of the three engine designs considered employ a Moog bipropellant torque motor valve, platelet injector design, and iridium-lined rhenium combustion chamber. Attention is focused on the performance, robustness, duration, and flexibility characteristics of the engines. It is noted that the 5- and 15-lbF thrust engines can deliver a steady state specific impulse in excess of 310 lbF-sec/lbm at an area ratio of 150:1, while the 150-lbF thrust engines deliver a steady state specific impulse of 320 lbF-sec/lbm at an area ratio of 250:1. The hot-fire test results reveal specific impulse improvements of 15 to 25 sec over conventional fuel film cooled columbium chamber designs while operating at maximum chamber temperatures.

  6. Transient performances analysis of wind turbine system with induction generator including flux saturation and skin effect

    DEFF Research Database (Denmark)

    Li, H.; Zhao, B.; Han, L.

    2010-01-01

    In order to analyze correctly the effect of different models for induction generators on the transient performances of large wind power generation, Wind turbine driven squirrel cage induction generator (SCIG) models taking into account both main and leakage flux saturation and skin effect were...

  7. Ascent performance feasibility for next-generation spacecraft

    Science.gov (United States)

    Mancuso, Salvatore Massimo

    This thesis deals with the optimization of the ascent trajectories for single-stage suborbital (SSSO), single-stage-to-orbit (SSTO), and two-stage-to-orbit (TSTO) rocket-powered spacecraft. The maximum payload weight problem has been solved using the sequential gradient-restoration algorithm. For the TSTO case, some modifications to the original version of the algorithm have been necessary in order to deal with discontinuities due to staging and the fact that the functional being minimized depends on interface conditions. The optimization problem is studied for different values of the initial thrust-to-weight ratio in the range 1.3 to 1.6, engine specific impulse in the range 400 to 500 sec, and spacecraft structural factor in the range 0.08 to 0.12. For the TSTO configuration, two subproblems are studied: uniform structural factor between stages and nonuniform structural factor between stages. Due to the regular behavior of the results obtained, engineering approximations have been developed which connect the maximum payload weight to the engine specific impulse and spacecraft structural factor; in turn, this leads to useful design considerations. Also, performance sensitivity to the scale of the aerodynamic drag is studied, and it is shown that its effect on payload weight is relatively small, even for drag changes approaching ± 50%. The main conclusions are that: the design of a SSSO configuration appears to be feasible; the design of a SSTO configuration might be comfortably feasible, marginally feasible, or unfeasible, depending on the parameter values assumed; the design of a TSTO configuration is not only feasible, but its payload appears to be considerably larger than that of a SSTO configuration. Improvements in engine specific impulse and spacecraft structural factor are desirable and crucial for SSTO feasibility; indeed, it appears that aerodynamic improvements do not yield significant improvements in payload weight.

  8. A study on improving the performance of steam generator using thermal analysis

    International Nuclear Information System (INIS)

    Li, Zhen Zhe; Heo, Kwang Su; Choi, Jun Hoo; Seol, Seoung Yun

    2008-01-01

    Steam generation mechanism is the key technology of domestic steam cleaner. Not only weight and price of steam cleaner but also the performance of steam generation mechanism must be considered to improve the competitive power of the products. In order to find out the mechanism which can be used to improve the performance of steam generator, the process of steam generation was studied at first. In the following step, possibility of control, safety of mechanism and etc were compared about the two candidated steam generation mechanism. Finally, the merit and drawback of each mechanism were summarized

  9. Evolution of management activities and performance of the Point Lepreau Steam Generators

    International Nuclear Information System (INIS)

    Slade, J.; Keating, J.; Gendron, T.

    2007-01-01

    The Point Lepreau steam generators have been in service since 1983 when the plant was commissioned. During the first thirteen years of operation, Point Lepreau steam generator maintenance issues led to 3-4% unplanned plant incapability Steam generator fouling, corrosion, and the introduction of foreign materials during maintenance led to six tube leaks, two unplanned outages, two lengthy extended outages, and degraded thermal performance during this period. In recognition of the link between steam generator maintenance activities and plant performance, improvements to steam generator management activities have been continuously implemented since 1987. This paper reviews the evolution of steam generator management activities at Point Lepreau and the resulting improved trends in performance. Plant incapability from unplanned steam generator maintenance has been close to zero since 1996. The positive trends have provided a strong basis for the management strategies developed for post-refurbishment operation. (author)

  10. Performance of Generating Plant: Managing the Changes. Part 2: Thermal Generating Plant Unavailability Factors and Availability Statistics

    Energy Technology Data Exchange (ETDEWEB)

    Curley, G. Michael [North American Electric Reliability Corporation (United States); Mandula, Jiri [International Atomic Energy Agency (IAEA)

    2008-05-15

    The WEC Committee on the Performance of Generating Plant (PGP) has been collecting and analysing power plant performance statistics worldwide for more than 30 years and has produced regular reports, which include examples of advanced techniques and methods for improving power plant performance through benchmarking. A series of reports from the various working groups was issued in 2008. This reference presents the results of Working Group 2 (WG2). WG2's main task is to facilitate the collection and input on an annual basis of power plant performance data (unit-by-unit and aggregated data) into the WEC PGP database. The statistics will be collected for steam, nuclear, gas turbine and combined cycle, hydro and pump storage plant. WG2 will also oversee the ongoing development of the availability statistics database, including the contents, the required software, security issues and other important information. The report is divided into two sections: Thermal generating, combined cycle/co-generation, combustion turbine, hydro and pumped storage unavailability factors and availability statistics; and nuclear power generating units.

  11. Performance of Generating Plant: Managing the Changes. Part 1: International availability data exchange for thermal generating plant

    Energy Technology Data Exchange (ETDEWEB)

    Stallard, G.S.; Deschaine, R. [Black and Veatch (United States)

    2008-05-15

    The WEC Committee on the Performance of Generating Plant (PGP) has been collecting and analysing power plant performance statistics worldwide for more than 30 years and has produced regular reports, which include examples of advanced techniques and methods for improving power plant performance through benchmarking. A series of reports from the various working groups was issued in 2008. This reference presents the results of Working Group 1 (WG1). WG1's primary focus is to analyse the best ways to measure, evaluate, and apply power plant performance and availability data to promote plant performance improvements worldwide. The paper explores the specific work activities of 2004-2007 to extend traditional analysis and benchmarking frameworks. It is divided into two major topics: Overview of current electric supply industry issues/trends; and, Technical Methods/Tools to evaluate performance in today's ESI.

  12. Generational Patterns in Mexican Americans' Academic Performance in an Unwelcoming Political Context

    Science.gov (United States)

    Moosmann, Danyel A. V.; Roosa, Mark W.; Knight, George P.

    2014-01-01

    Research has shown that immigrant students often do better academically than their U.S.-born peers from the same ethnic group but it is unclear whether this pattern holds for Mexican Americans. We examined the academic performance of four generations of Mexican American students from fifth to 10th grade looking for generation differences and explanations for them. Using data from 749 families, we tested a model with fifth grade variables that differed by generation as potential mediators linking student generation to 10th grade academic performance. Results showed that immigrants were academically behind at fifth grade but caught up by seventh. Only economic hardship mediated the long term relationship between student generation and 10th grade academic performance; maternal educational expectations and child language hassles, English usage, discrimination, and mainstream values helped explained the early academic deficit of immigrant children. The results identified potential targets for interventions to improve Mexican American students' academic performance. PMID:24578588

  13. Advanced life-cycle management for an increased steam generator performance

    International Nuclear Information System (INIS)

    Beck, J.; Schwarz, T.; Bouecke, R.; Schneider, V.

    2006-01-01

    High steam generators performance is a prerequisite for high plant availability and possible life time extension. During operation, the performance is reduced by fouling of the heating tubes and by corrosion, resulting on a reduction of the heat-exchange area. Such steam generator degradation problems arise from mechanical degradation and a continuous ingress of non-volatile contaminants, i.e. corrosion products and salt impurities accumulated in the steam generators. In addition, the tube scales in general affect the steam generator thermal performance, which ultimately cause a reduction of power output. AREVA applied an integrated service for utilities to evaluate all operational parameters influencing the steam generator performance. The evaluation is assisted by a systematic approach to evaluate the major steam generator operational data. The different data are structured and indexed in a Cleanling-Matrix. The result of this matrix is a quantified, dimensionless figure, given as the Fouling Index. The Fouling Index allows to monitor the condition of steam generators, compare it to other plants and, in combination with a life-time management applied at several German utilities, it allows verified statements on the past operation. Based on these data, an extrapolation of the potential additional life-time of the component is possible. As such, the Fouling Index is a valuable tool concerning life-time extension considerations. The application of the cleanliness criteria in combination with operational data with respect to life-time monitoring and improvements of steam generator performance are presented. (author)

  14. Seawave Slot-Cone Generator

    DEFF Research Database (Denmark)

    Vicinanza, Diego; Margheritini, Lucia; Contestabile, Pasquale

    2009-01-01

    This paper discusses a new type of Wave Energy Converter (WEC) named Seawave Slot-Cone Generator (SSG). The SSG is a WEC of the overtopping type. The structure consists of a number of reservoirs one on the top of each others above the mean water level in which the water of incoming waves is store...... on sloping walls constituting the structure. The research is intended to be of direct use to engineers analyzing design and stability of this peculiar kind of coastal structure....

  15. The Performance of a Second Generation Service Discovery Protocol In Response to Message Loss

    NARCIS (Netherlands)

    Sundramoorthy, V.; van de Glind, G.J.; Hartel, Pieter H.; Scholten, Johan

    We analyze the behavior of FRODO, a second generation service discovery protocol, in response to message loss in the network. First generation protocols, like UPnP and Jini rely on underlying network layers to enhance their failure recovery. A comparison with UPnP and Jini shows that FRODO performs

  16. Effect of tube plugging in the thermalhydraulic performance of 'U' tube steam generators

    International Nuclear Information System (INIS)

    Braga, C.V.M.; Carajilescov, P.

    1981-05-01

    The thermalhydraulic performance of Angra II steam generator has been simulated using the model developed by Braga, C.V.M., 'Thermohydraulic model for steam generator of PWR power plants', in steady state, with plugging up to 40% of total number of tubes. (E.G.) [pt

  17. Performance Limiting Effects in Power Generation from Salinity Gradients by Pressure Retarded Osmosis

    KAUST Repository

    Yip, Ngai Yin; Elimelech, Menachem

    2011-01-01

    Pressure retarded osmosis has the potential to utilize the free energy of mixing when fresh river water flows into the sea for clean and renewable power generation. Here, we present a systematic investigation of the performance limiting phenomena

  18. Chemical and physical parameters affecting the performance of the Os-191/Ir-191m generator

    International Nuclear Information System (INIS)

    Packard, A.B.; Butler, T.A.; Knapp, F.F.; O'Brien, G.M.; Treves, S.

    1984-01-01

    The development of an Os-191/Ir-191m generator suitable for radionuclide angiography in humans has elicited much interest. This generator employs ''(OsO 2 Cl 4 ) 2- '' on AG MP-1 anion exchange resin with a Dowex-2 scavenger column and is eluted with normal saline at pH 1. The parent Os species is, however, neither welldefined nor homogeneous leading to less than optimal breakthrough of Os-191 (5 x 10 -3 %) and modest Ir-191m yield (10-15%). The effect of a range of parameters on generator performance has been evaluated as has been the way in which the assembly and loading process affects generator performance. In addition, a number of potential alternative generator systems have been evaluated

  19. Availability of thermodynamic system with multiple performance parameters based on vector-universal generating function

    International Nuclear Information System (INIS)

    Cai Qi; Shang Yanlong; Chen Lisheng; Zhao Yuguang

    2013-01-01

    Vector-universal generating function was presented to analyze the availability of thermodynamic system with multiple performance parameters. Vector-universal generating function of component's performance was defined, the arithmetic model based on vector-universal generating function was derived for the thermodynamic system, and the calculation method was given for state probability of multi-state component. With the stochastic simulation of the degeneration trend of the multiple factors, the system availability with multiple performance parameters was obtained under composite factors. It is shown by an example that the results of the availability obtained by the binary availability analysis method are somewhat conservative, and the results considering parameter failure based on vector-universal generating function reflect the operation characteristics of the thermodynamic system better. (authors)

  20. Does Online Chatter Really Matter? Dynamics of User-Generated Content and Stock Performance

    NARCIS (Netherlands)

    S. Tirunillai (Seshadri); G.J. Tellis (Gerard)

    2011-01-01

    textabstractUser-Generated Content in online platforms or chatter for short provides a valuable source of consumer feedback on market performance of firms. This study examines whether chatter can predict stock market performance, which metric of chatter has the strongest relationship, and what the

  1. Implementation status of performance demonstration program for steam generator tubing analysts in Korea

    International Nuclear Information System (INIS)

    Cho, Chan Hee; Lee, Hee Jong; Yoo, Hyun Ju; Nam, Min Woo; Hong, Sung Yull

    2013-01-01

    Some essential components in nuclear power plants are periodically inspected using non destructive examinations, for example ultrasonic, eddy current and radiographic examinations, in order to determine their integrity. These components include nuclear power plant items such as vessels, containments, piping systems, pumps, valves, tubes and core support structure. Steam generator tubes have an important safety role because they constitute one of the primary barriers between the radioactive and non radioactive sides of the nuclear power plant. There is potential that if a tube bursts while a plant is operating, radioactivity from the primary coolant system could escape directly to the atmosphere. Therefore, in service inspections are critical in maintaining steam generator tube integrity. In general, the eddy current testing is widely used for the inspection of steam generator tubes due tube integrity. In general, the eddy current testing is widely used for the inspection of steam generator tubes due to its high inspection speed and flaw detectability on non magnetic tubes. However, it is not easy to analyze correctly eddy current signals because they are influenced by many factors. Therefore, the performance of eddy current data analysts for steam generator tubing should be demonstrated comprehensively. In Korea, the performance of steam generator tubing analysts has been demonstrated using the Qualified Data Analyst program. This paper describes the performance demonstration program for steam generator tubing analysts and its implementation results in Korea. The pass rate of domestic analysts for this program was 71.4%

  2. Thermal-Hydraulic Analysis of a Once-Through Steam Generator Considering Performance Degradation

    Energy Technology Data Exchange (ETDEWEB)

    Han, Hun Sik; Kang, Han Ok; Yoon, Ju Hyeon; Kim, Young In; Song, Jae Seung; Kim, Keung Koo [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    Several countries have entered into a global race for the commercialization of SMRs, and considerable research and development have been implemented. Among the various reactor designs, many SMRs have adopted an integral type pressurized water reactor (PWR) to enhance the nuclear safety and system reliability. In the integral reactor design, a single reactor pressure vessel contains primary system components such as fuel and core, steam generators, pumps, and a pressurizer. For the component integration into a reactor vessel, it is important to design each component as small as possible. Thus, it is a common practice to employ a once-through steam generator in the integral reactor design due to its advantages in compactness. In general, gradual degradation in thermal-hydraulic performance of the steam generator occurs with time, and it changes slowly the operating point of the steam generator during plant lifetime. Numerical solutions are acquired to evaluate the thermal-hydraulic performance of the steam generator at various AUFs. The design results obtained show that the average tube length of the steam generator is augmented with the increase of design margin to compensate for the design uncertainties and heat transfer area reduction by plugging, fouling, etc. A helically coiled tube once-through steam generator with 30% design margin is considered for comparison of thermal-hydraulic performances according to the degradation rate.

  3. An effect of downcomer feedwater fraction on steam generator performance with an axial flow economizer

    International Nuclear Information System (INIS)

    Jung, Byung Ryul; Park, Hu Shin; Chung, Duk Muk; Baik, Se Jin

    2000-01-01

    The effects of feedwater flow fraction introduced into the downcomer region have been evaluated in terms of steam generator performance based on the same steam generator thermal output for the Korea Standard Nuclear Power Plant (KSNP) steam generator. The KSNP steam generator design has an integral axial flow economizer which is designed such that most of the feedwater is introduced through the economizer region and only a portion of feedwater through the downcomer region. The feedwater flow introduced into the downcomer region is not normally controlled during the power operation. However, the actual feedwater fraction into the downcomer region may differ from the design flow depending on the as-built system and component characteristics. Investigated in this paper were the downcomer feedwater flow effects on the steam pressure, circulation ratio, internal void fraction and velocity distribution in the tube bundle region at the steady state operation using SAFE and ATHOS3 codes. The results show that the steam pressure increases and the resultant total feedwater flow increases with reducing the downcomer feedwater flow fraction for the same steam generator thermal output. The slight off-design condition of downcomer feedwater flow fraction renders no significant effect on the steam generator performance such as circulation ratios, steam qualities, void fractions and internal velocity distributions. The evaluation shows that the slight off-design downcomer feedwater flow fraction deviation up to ± 5% is acceptable for the steam generator performance

  4. Thermal-Hydraulic Analysis of a Once-Through Steam Generator Considering Performance Degradation

    International Nuclear Information System (INIS)

    Han, Hun Sik; Kang, Han Ok; Yoon, Ju Hyeon; Kim, Young In; Song, Jae Seung; Kim, Keung Koo

    2016-01-01

    Several countries have entered into a global race for the commercialization of SMRs, and considerable research and development have been implemented. Among the various reactor designs, many SMRs have adopted an integral type pressurized water reactor (PWR) to enhance the nuclear safety and system reliability. In the integral reactor design, a single reactor pressure vessel contains primary system components such as fuel and core, steam generators, pumps, and a pressurizer. For the component integration into a reactor vessel, it is important to design each component as small as possible. Thus, it is a common practice to employ a once-through steam generator in the integral reactor design due to its advantages in compactness. In general, gradual degradation in thermal-hydraulic performance of the steam generator occurs with time, and it changes slowly the operating point of the steam generator during plant lifetime. Numerical solutions are acquired to evaluate the thermal-hydraulic performance of the steam generator at various AUFs. The design results obtained show that the average tube length of the steam generator is augmented with the increase of design margin to compensate for the design uncertainties and heat transfer area reduction by plugging, fouling, etc. A helically coiled tube once-through steam generator with 30% design margin is considered for comparison of thermal-hydraulic performances according to the degradation rate

  5. Implementation status of performance demonstration program for steam generator tubing analysts in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Chan Hee; Lee, Hee Jong; Yoo, Hyun Ju; Nam, Min Woo [KHNP Central Research Institute, Daejeon (Korea, Republic of); Hong, Sung Yull [Yeungnam Univ., Gyeongsan (Korea, Republic of)

    2013-02-15

    Some essential components in nuclear power plants are periodically inspected using non destructive examinations, for example ultrasonic, eddy current and radiographic examinations, in order to determine their integrity. These components include nuclear power plant items such as vessels, containments, piping systems, pumps, valves, tubes and core support structure. Steam generator tubes have an important safety role because they constitute one of the primary barriers between the radioactive and non radioactive sides of the nuclear power plant. There is potential that if a tube bursts while a plant is operating, radioactivity from the primary coolant system could escape directly to the atmosphere. Therefore, in service inspections are critical in maintaining steam generator tube integrity. In general, the eddy current testing is widely used for the inspection of steam generator tubes due tube integrity. In general, the eddy current testing is widely used for the inspection of steam generator tubes due to its high inspection speed and flaw detectability on non magnetic tubes. However, it is not easy to analyze correctly eddy current signals because they are influenced by many factors. Therefore, the performance of eddy current data analysts for steam generator tubing should be demonstrated comprehensively. In Korea, the performance of steam generator tubing analysts has been demonstrated using the Qualified Data Analyst program. This paper describes the performance demonstration program for steam generator tubing analysts and its implementation results in Korea. The pass rate of domestic analysts for this program was 71.4%.

  6. Track 2- major components reliability and materials issues. Some performance indicators of PWR steam generators

    International Nuclear Information System (INIS)

    Milivojevic, S.; Spasojevic, D.; Riznic, J.

    2001-01-01

    The monitoring of operational performance is a crucial aspect of the management of equipment operation and maintenance in many industries, including nuclear and thermal power plants. Monitoring involves the collection and analysis of data on the operation. In these paper an analysis was made of steam generators in operation, i.e., their malfunctions during the plant life cycle with the aim of studying the characteristics of failure rate and repair rate. These values are necessary parameters if we are to determine the reliability and availability of the steam generator as a basis for the analysis of its effect on the safety and efficiency of the nuclear power plant. We analyzed IAEA available data for period from 1971 to 1998. Each steam generator was monitored individually during plants' lifetime. The data on steam generator failures were presented in uniform format, allowing the consistency in failure classification and data reporting. Operational presence of the analyzed steam generators is given for each calendar year and each lifetime year: the failure rate l and repair rate m with associated boundaries are calculated. The general trends in calendar years performance indicators (μ) of steam generators is investigated. The distributions of lifetime l and m are formed, as a complement to the analysis of calendar years performance indicators. With aspect of steam generators influence on reliability and availability of nuclear power plants, the empirical probability distribution for failure rates and repair rates are also constructed. (author)

  7. The Effect of Training Data Set Composition on the Performance of a Neural Image Caption Generator

    Science.gov (United States)

    2017-09-01

    REPORT TYPE Technical Report 3. DATES COVERED (From - To) 4. TITLE AND SUBTITLE The Effect of Training Data Set Composition on the Performance of a...ARL-TR-8124 ● SEP 2017 US Army Research Laboratory The Effect of Training Data Set Composition on the Performance of a Neural...Laboratory The Effect of Training Data Set Composition on the Performance of a Neural Image Caption Generator by Abigail Wilson Montgomery Blair

  8. High-Performance Pseudo-Random Number Generation on Graphics Processing Units

    OpenAIRE

    Nandapalan, Nimalan; Brent, Richard P.; Murray, Lawrence M.; Rendell, Alistair

    2011-01-01

    This work considers the deployment of pseudo-random number generators (PRNGs) on graphics processing units (GPUs), developing an approach based on the xorgens generator to rapidly produce pseudo-random numbers of high statistical quality. The chosen algorithm has configurable state size and period, making it ideal for tuning to the GPU architecture. We present a comparison of both speed and statistical quality with other common parallel, GPU-based PRNGs, demonstrating favourable performance o...

  9. Performance tests on column materials for {sup 99}Mo-{sup 99m}Tc generator

    Energy Technology Data Exchange (ETDEWEB)

    Sombrito, E Z; Bulos, A D; Tangonan, M C [Chemistry Research Section, Atomic Research Div., Philippine Nuclear Research Inst., Quezon (Philippines)

    1998-10-01

    To meet the need of producing a {sup 99}Mo-{sup 99m}Tc generator, based on low specific activity reactor-produced {sup 99}Mo, different procedures for preparing zirconium molybdate gels were tested. Performance tests were done on molybdate gel columns prepared using the procedures developed by Vietnam and China, and recently, on a polyzirconium compound (PZC) prepared in Japan. The conditions for the batch drying of a large volume of the gel material were studied as well as the conditions in preparing a column to concentrate technetium-99m. The performance of PZC sample as column material for the generator was also evaluated. (author)

  10. Effect of Dimension and Shape of Magnet on the Performance AC Generator with Translation Motion

    Science.gov (United States)

    Indriani, A.; Dimas, S.; Hendra

    2018-02-01

    The development of power plants using the renewable energy sources is very rapid. Renewable energy sources used solar energy, wind energy, ocean wave energy and other energy. All of these renewable energy sources require a processing device or a change of motion system to become electrical energy. One processing device is a generator which have work principle of converting motion (mechanical) energy into electrical energy with rotary shaft, blade and other motion components. Generator consists of several types of rotation motion and linear motion (translational). The generator have components such as rotor, stator and anchor. In the rotor and stator having magnet and winding coil as an electric generating part of the electric motion force. Working principle of AC generator with linear motion (translation) also apply the principle of Faraday that is using magnetic induction which change iron magnet to produce magnetic flux. Magnetic flux is captured by the stator to be converted into electrical energy. Linear motion generators consist of linear induction machine, wound synchronous machine field, and permanent magnet synchronous [1]. Performance of synchronous generator of translation motion is influenced by magnet type, magnetic shape, coil winding, magnetic and coil spacing and others. In this paper focus on the neodymium magnet with varying shapes, number of coil windings and gap of magnetic distances. This generator work by using pneumatic mechanism (PLTGL) for power plants system. Result testing of performance AC generator translation motion obtained that maximum voltage, current and power are 63 Volt for diameter winding coil 0.15 mm, number of winding coil 13000 and distance of magnet 20 mm. For effect shape of magnet, maximum voltage happen on rectangle magnet 30x20x5 mm with 4.64 Volt. Voltage and power on effect of diameter winding coil is 14.63 V and 17.82 W at the diameter winding coil 0.7 and number of winding coil is 1260 with the distance of magnet 25

  11. Entropy Generation Analysis and Performance Evaluation of Turbulent Forced Convective Heat Transfer to Nanofluids

    Directory of Open Access Journals (Sweden)

    Yu Ji

    2017-03-01

    Full Text Available The entropy generation analysis of fully turbulent convective heat transfer to nanofluids in a circular tube is investigated numerically using the Reynolds Averaged Navier–Stokes (RANS model. The nanofluids with particle concentration of 0%, 1%, 2%, 4% and 6% are treated as single phases of effective properties. The uniform heat flux is enforced at the tube wall. To confirm the validity of the numerical approach, the results have been compared with empirical correlations and analytical formula. The self-similarity profiles of local entropy generation are also studied, in which the peak values of entropy generation by direct dissipation, turbulent dissipation, mean temperature gradients and fluctuating temperature gradients for different Reynolds number as well as different particle concentration are observed. In addition, the effects of Reynolds number, volume fraction of nanoparticles and heat flux on total entropy generation and Bejan number are discussed. In the results, the intersection points of total entropy generation for water and four nanofluids are observed, when the entropy generation decrease before the intersection and increase after the intersection as the particle concentration increases. Finally, by definition of Ep, which combines the first law and second law of thermodynamics and attributed to evaluate the real performance of heat transfer processes, the optimal Reynolds number Reop corresponding to the best performance and the advisable Reynolds number Read providing the appropriate Reynolds number range for nanofluids in convective heat transfer can be determined.

  12. Performance analysis of a waste heat recovery thermoelectric generation system for automotive application

    International Nuclear Information System (INIS)

    Liu, X.; Deng, Y.D.; Li, Z.; Su, C.Q.

    2015-01-01

    Graphical abstract: A new automotive exhaust-based thermoelectric generator and its “four-TEGs” system are constructed, and the performance characteristics of system are discussed through road test and revolving drum test. - Highlights: • The automotive thermoelectric generator system was constructed and studied. • Road test and revolving drum test were used to measure the output power. • A performance of 201.7 V (open circuit voltage)/944 W obtained. - Abstract: Thermoelectric power generators are one of the promising green energy sources. In this case study, an energy-harvesting system which extracts heat from an automotive exhaust pipe and turns the heat into electricity by using thermoelectric power generators (TEGs) has been constructed. The test bench is developed to analysis the performance of TEG system characteristics, which are undertaken to assess the feasibility of automotive applications. Based on the test bench, a new system called “four-TEGs” system is designed and assembled into prototype vehicle called “Warrior”, through the road test and revolving drum test table, characteristics of the system such as hot-side temperature, cold-side temperature, open circuit voltage and power output are studied, and a maximum power of 944 W was obtained, which completely meets the automotive application. The present study shows the promising potential of using this kind of thermoelectric generator for low-temperature waste heat recovery vehicle

  13. Low Cost High Performance Generator Technology Program. Volume 2. Design study

    International Nuclear Information System (INIS)

    1975-06-01

    The systems studies directed towards up-rating the performance of an RTG using selenide thermoelectrics and a heat source with improved safety are reported. The resulting generator design, designated LCHPG, exhibits conversion efficiency of greater than 10 percent, a specific power of 3 W/lb., and a cost of $6,000/W(e). In the course of system analyses, the significant development activities required to achieve this performance by the 1980 time period are identified

  14. Control design and performance analysis of a 6 MW wind turbine-generator

    Science.gov (United States)

    Murdoch, A.; Winkelman, J. R.; Javid, S. H.; Barton, R. S.

    1983-01-01

    This paper discusses an approach to the modeling and performance for the preliminary design phase of a large (6.2 MW) horizontal axis wind turbine generator (WTG). Two control philosophies are presented, both of which are based on linearized models of the WT mechanical and electrical systems. The control designs are compared by showing the performance through detailed non-linear time simulation. The disturbances considered are wind gusts, and electrical faults near the WT terminals.

  15. Performance of Generating Plant: Managing the Changes. Executive Summary and Table of Contents

    Energy Technology Data Exchange (ETDEWEB)

    Curley, G. Michael [North American Electric Reliability Corporation (United States); Mandula, Jiri [International Atomic Energy Agency (IAEA)

    2008-05-15

    The WEC Committee on the Performance of Generating Plant (PGP) has been collecting and analysing power plant performance statistics worldwide for more than 30 years and has produced regular reports, which include examples of advanced techniques and methods for improving power plant performance through benchmarking. A series of reports from the various working groups was issued in 2008. This document serves as a supporting paper. Sections include: features of Italian energy and electricity; the evolution of liberalisation; support mechanism for renewables; connection to wind farm transmission network; wind source integration into power system; and, final comments. The WEC Committee on the Performance of Generating Plant (PGP) has been collecting and analysing power plant performance statistics worldwide for more than 30 years and has produced regular reports, which include examples of advanced techniques and methods for improving power plant performance through benchmarking. A series of reports from the various working groups was issued in 2008. This reference presents the results of Working Group 1 (WG1). WG1's primary focus is to analyse the best ways to measure, evaluate, and apply power plant performance and availability data to promote plant performance improvements worldwide. The paper explores the specific work activities of 2004-2007 to extend traditional analysis and benchmarking frameworks. It is divided into two major topics: Overview of current electric supply industry issues/trends; and, Technical Methods/Tools to evaluate performance in today's ESI.

  16. Improving the performance of galloping micro-power generators by passively manipulating the trailing edge

    Science.gov (United States)

    Noel, J.; Yadav, R.; Li, G.; Daqaq, M. F.

    2018-02-01

    Recent trends in distributed sensing networks have generated significant interest in the design of scalable micro-power generators. One such device exploits the galloping oscillations of a prism to harness energy from a moving fluid. Performance of galloping harvester's depends on the flow patterns around the prism, which, in turn, depend on its geometry and the Reynolds number of the flow. In this letter, we demonstrate that the useful range of the galloping instability can be extended by attaching a rigid splitter plate to the rear face of the prism. The plate provides a secondary flow reattachment point, which serves to improve the oscillation amplitude and power output of the generator. Experimental results demonstrate as much as 67% power enhancement for some prism geometries and a significant reduction in the cut-in wind speed of the generator.

  17. Performance Analysis of Savonius Rotor Based Hydropower Generation Scheme with Electronic Load Controller

    Directory of Open Access Journals (Sweden)

    Rajen Pudur

    2016-01-01

    Full Text Available This paper describes the performance of electronic load controller (ELC of asynchronous generator (AG coupled to an uncontrolled Savonius turbine and variable water velocity. An AC-DC-AC converter with a dc link capacitor is employed to maintain the required frequency. The ELC which is feeding a resistive dump load is connected in parallel with the generating system and the power consumption is varied through the duty cycle of the chopper. Gate triggering of ELC is accomplished through sinusoidal pulse width modulation (SPWM by sensing the load current. A MATLAB/Simulink model of Savonius rotor, asynchronous generator, ELC, and three-phase load is presented. The proposed scheme is tested under various load conditions under varying water velocities and the performances are observed to be satisfactory.

  18. Performance simulation of a spark ignited free-piston engine generator

    Energy Technology Data Exchange (ETDEWEB)

    Mikalsen, R.; Roskilly, A.P. [Sir Joseph Swan Institute for Energy Research, University of Newcastle upon Tyne, Newcastle upon Tyne, NE1 7RU (United Kingdom)

    2008-10-15

    Free-piston engines are under investigation by a number of research groups worldwide due to potential fuel efficiency and engine emissions advantages. The free-piston engine generator, in which a linear electric generator is fixed to the mover to produce electric power, has been proposed as an alternative prime mover for hybrid-electric vehicles. This paper investigates the performance of a spark ignited free-piston engine generator and compares it to a conventional engine using a computational fluid dynamics simulation model. The particular operating characteristics of the free-piston engine were not found to give noticeable performance advantages, and it is concluded that the main potential of this technology lies in the simplicity and flexibility of the concept. (author)

  19. Acoustic performance of dual-electrode electrostatic sound generators based on CVD graphene on polyimide film.

    Science.gov (United States)

    Lee, Kyoung-Ryul; Jang, Sung Hwan; Jung, Inhwa

    2018-08-10

    We investigated the acoustic performance of electrostatic sound-generating devices consisting of bi-layer graphene on polyimide film. The total sound pressure level (SPL) of the sound generated from the devices was measured as a function of source frequency by sweeping, and frequency spectra were measured at 1/3 octave band frequencies. The relationship between various operation conditions and total SPL was determined. In addition, the effects of changing voltage level, adding a DC offset, and using two pairs of electrodes were evaluated. It should be noted that two pairs of electrode operations improved sound generation by about 10 dB over all frequency ranges compared with conventional operation. As for the sound-generating capability, total SPL was 70 dBA at 4 kHz when an AC voltage of 100 V pp was applied with a DC offset of 100 V. Acoustic characteristics differed from other types of graphene-based sound generators, such as graphene thermoacoustic devices and graphene polyvinylidene fluoride devices. The effects of diameter and distance between electrodes were also studied, and we found that diameter greatly influenced the frequency response. We anticipate that the design information provided in this paper, in addition to describing key parameters of electrostatic sound-generating devices, will facilitate the commercial development of electrostatic sound-generating systems.

  20. Model and performance of current sensor observers for a doubly fed induction generator

    DEFF Research Database (Denmark)

    Li, Hui; Yang, Chao; Hu, Yaogang

    2014-01-01

    . A stator and rotor current observer model, which is based on the state-space models of doubly fed induction generators, is then derived by using the stator and rotor voltage signals as inputs. To demonstrate the effectiveness of the proposed current observer, its dynamic performance is simulated using...

  1. Balancing Performance and Sustainability in Next-Generation PMR Technologies for OMC Structures

    Science.gov (United States)

    2016-05-26

    John J. La Scala , Benjamin G. Harvey, Giuseppe R. Palmese, William S. Eck, Joshua M. Sadler, Santosh K. Yadav 5d. PROJECT NUMBER 5e. TASK NUMBER...PERFORMANCE AND SUSTAINABILITY IN NEXT-GENERATION PMR TECHNOLOGIES FOR OMC STRUCTURES Gregory R. Yandek,1 Jason T. Lamb,2 John J. La Scala ,3 Benjamin G

  2. Comparative Performance Evaluation of Orthogonal-Signal-Generators-Based Single-Phase PLL Algorithms

    DEFF Research Database (Denmark)

    Han, Yang; Luo, Mingyu; Zhao, Xin

    2016-01-01

    The orthogonal signal generator based phase-locked loops (OSG-PLLs) are among the most popular single-phase PLLs within the areas of power electronics and power systems, mainly because they are often easy to be implement and offer a robust performance against the grid disturbances. The main aim o...

  3. The Performance of a Second Generation Service Discovery Protocol In Response to Message Loss

    NARCIS (Netherlands)

    Sundramoorthy, V.; van de Glind, G.J.; Hartel, Pieter H.; Scholten, Johan

    We analyze the behavior of FRODO, a second generation service discovery protocol, in response to message loss in the network. Earlier protocols, like UPnP and Jini rely on underlying network layers to enhance their failure recovery. A comparison with UPnP and Jini shows that FRODO performs more

  4. Performance of genomic prediction within and across generations in maritime pine

    NARCIS (Netherlands)

    Bartholomé, Jérôme; Heerwaarden, Van Joost; Isik, Fikret; Boury, Christophe; Vidal, Marjorie; Plomion, Christophe; Bouffier, Laurent

    2016-01-01

    Background: Genomic selection (GS) is a promising approach for decreasing breeding cycle length in forest trees. Assessment of progeny performance and of the prediction accuracy of GS models over generations is therefore a key issue. Results: A reference population of maritime pine (Pinus

  5. Volatility Spillovers Across User-Generated Content and Stock Market Performance

    NARCIS (Netherlands)

    M. van Dieijen (Myrthe); A. Borah (Abhishek); G.J. Tellis (Gerard); Ph.H.B.F. Franses (Philip Hans)

    2016-01-01

    textabstractVolatility is an important metric of financial performance, indicating uncertainty or risk. So, predicting and managing volatility is of interest to both company managers and investors. This study investigates whether volatility in user-generated content (UGC) can spill over to

  6. Performance demonstration tests for eddy current inspection of steam generator tubing

    International Nuclear Information System (INIS)

    Kurtz, R.J.; Heasler, P.G.; Anderson, C.M.

    1996-05-01

    This report describes the methodology and results for development of performance demonstration tests for eddy current (ET) inspection of steam generator tubes. Statistical test design principles were used to develop the performance demonstration tests. Thresholds on ET system inspection performance were selected to ensure that field inspection systems would have a high probability of detecting and and correctly sizing tube degradation. The technical basis for the ET system performance thresholds is presented in detail. Statistical test design calculations for probability of detection and flaw sizing tests are described. A recommended performance demonstration test based on the design calculations is presented. A computer program for grading the probability of detection portion of the performance demonstration test is given

  7. Performance demonstration tests for eddy current inspection of steam generator tubing

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, R.J.; Heasler, P.G.; Anderson, C.M.

    1996-05-01

    This report describes the methodology and results for development of performance demonstration tests for eddy current (ET) inspection of steam generator tubes. Statistical test design principles were used to develop the performance demonstration tests. Thresholds on ET system inspection performance were selected to ensure that field inspection systems would have a high probability of detecting and and correctly sizing tube degradation. The technical basis for the ET system performance thresholds is presented in detail. Statistical test design calculations for probability of detection and flaw sizing tests are described. A recommended performance demonstration test based on the design calculations is presented. A computer program for grading the probability of detection portion of the performance demonstration test is given.

  8. Variable-Speed Generation Subsystem Using the Doubly-Fed Generator; Period of Performance February 9, 1994 - April 30, 1999

    Energy Technology Data Exchange (ETDEWEB)

    Weigand, C.H.; Lauw, H.K.; Marckx, D.A. (Electronic Power Conditioning Incorporated)

    2000-12-18

    Over the past decade, fixed-speed, utility-scale wind turbines have technically advanced to a point where they can economically complete against nuclear and fossil-fuel-based power plants in geographical areas with a sufficient wind resource. The objective of this subcontract was to compare various electrical topologies allowing variable-speed turbine operation, identify the most suitable for a 275-kW (or larger) utility-scale wind turbine, and then design, build, lab test, and field test this variable-speed generation subsystem based on the previously identified optimum approach. Preliminary tests of the controls for a doubly fed variable-speed generation system rated at 750 kW were performed on a wind turbine. A 275-kW VSGS was thoroughly tested in the laboratory and on a wind turbine. Using field-oriented control, excellent dynamic behavior of the drive train was demonstrated, acoustic tests revealed an 11 dB reduction in turbine noise in low-wind, low-RPM operation compared to fixed-speed operation. The overall efficiency of the electrical system suffered from inadequate efficiency of the power converter at low power. Consequently, a different converter topology has been proposed that will satisfy both efficiency and power quality requirements for future use. This report provides information on all aspects of the project, including events that were unanticipated at the outset. A great deal of information is available in the references, comprised of NREL reports, journal articles, and conference papers on specific project results.

  9. Temperature effect on the performance of a dissipative dielectric elastomer generator with failure modes

    International Nuclear Information System (INIS)

    Chen, S E; Deng, L; He, Z C; Li, Eric; Li, G Y

    2016-01-01

    Research on dielectric elastomer generators (DEGs) which can be utilized to convert mechanical energy to electrical energy has gained wide attention lately. However, very few works account for the operating temperature, viscoelasticity and current leakage in the analysis of DEGs simultaneously. In this study, under several compound four-stroke conversion cycles, the electromechanical performance and energy conversion of a dissipative DEG made of a very-high-bond (VHB) elastomer are investigated at different operating temperatures. The performance parameters such as energy density and conversion efficiency are calculated under different temperatures. Moreover, the common failure modes of the generator are considered: material rupture, loss of tension, electrical breakdown and electromechanical instability. The numerical results have distinctly shown that the operating temperature plays an important role in the performance of DEGs, which could possibly make a larger conversion efficiency for the DEG. (paper)

  10. Next-generation fiber lasers enabled by high-performance components

    Science.gov (United States)

    Kliner, D. A. V.; Victor, B.; Rivera, C.; Fanning, G.; Balsley, D.; Farrow, R. L.; Kennedy, K.; Hampton, S.; Hawke, R.; Soukup, E.; Reynolds, M.; Hodges, A.; Emery, J.; Brown, A.; Almonte, K.; Nelson, M.; Foley, B.; Dawson, D.; Hemenway, D. M.; Urbanek, W.; DeVito, M.; Bao, L.; Koponen, J.; Gross, K.

    2018-02-01

    Next-generation industrial fiber lasers enable challenging applications that cannot be addressed with legacy fiber lasers. Key features of next-generation fiber lasers include robust back-reflection protection, high power stability, wide power tunability, high-speed modulation and waveform generation, and facile field serviceability. These capabilities are enabled by high-performance components, particularly pump diodes and optical fibers, and by advanced fiber laser designs. We summarize the performance and reliability of nLIGHT diodes, fibers, and next-generation industrial fiber lasers at power levels of 500 W - 8 kW. We show back-reflection studies with up to 1 kW of back-reflected power, power-stability measurements in cw and modulated operation exhibiting sub-1% stability over a 5 - 100% power range, and high-speed modulation (100 kHz) and waveform generation with a bandwidth 20x higher than standard fiber lasers. We show results from representative applications, including cutting and welding of highly reflective metals (Cu and Al) for production of Li-ion battery modules and processing of carbon fiber reinforced polymers.

  11. Review of freeboard: Grand Rapids Generating Station

    Energy Technology Data Exchange (ETDEWEB)

    Groeneveld, J.L.; Harding, W.B.; Bonin, D.V.; Fuchs, D.M. [Acres Manitoba Ltd., Winnipeg, MB (Canada); Warner, B.J. [Manitoba Hydro, Winnipeg, MB (Canada)

    2001-10-01

    Constructed during the period 1960-1965, the Grand Rapids Generating Station is a 472 MW hydroelectric station located approximately 400 kilometres northwest of Winnipeg, Manitoba, on the Saskatchewan River. An intake structure, four penstocks, a four-unit plus house unit powerhouse, wing walls, extensive dyke structures and a four-bay spillway are the components of the generating station. A little over ten years ago, the Manitoba Hydro Dam Safety Program was initiated. The program included a detailed dam safety review of the Grand rapids Generating Station. A potential deficiency in the freeboard allowance for several of the earthen dykes was revealed by the review process. The dam safety guidelines sponsored by the Canadian Dam Association were not met. The occurrence of a 1:1000 year wind event from the critical direction when the reservoir was at or near its full supply level was compounded by the analysis. The establishment of a wind and wave monitoring program was included in the deficiency studies commissioned. The objective was to confirm the empirical estimates concerning wave height, the development and usage of a two dimensional numerical wave model, and additional freeboard analyses to refine estimates of the recurrence interval of the current level of protection. A statistical Monte Carlo analysis was performed in the case of the estimates of the recurrence interval to determine the joint probabilities of seasonal variations in wind direction, wind speed, and reservoir level. The estimate of the actual risk of overtopping was therefore refined, and the details pertaining to the methodology and the conclusions of the analysis are all included in the paper. 15 refs., 4 tabs., 9 figs.

  12. Performance evaluation of a tri-generation system with simulation and experiment

    International Nuclear Information System (INIS)

    Ge, Y.T.; Tassou, S.A.; Chaer, I.; Suguartha, N.

    2009-01-01

    A test rig for a tri-generation system was set up in the laboratory to investigate the system performance and application feasibility. The rig was composed of three modules, a power component containing a microturbine, a refrigeration unit consisting of an absorption chiller with gas pipe connection, and a supermarket section containing a display cabinet. This system was supposed to be effectively applied into a supermarket energy control system where cooling, heating and electricity power are simultaneously required and subsequently, valuable test results have been produced. In the mean time, a simulation model for the particular tri-generation system has been established by integrating the component models of the system in accordance with the components' actual flow paths and energy streams. These component models, which include a compressor, recuperator, combustion chamber, gas turbine, electric generator, gas pipes, generator (desorber), rectifier, absorbers, condenser and evaporator etc., were developed based upon the balance of heat and mass. The calculations of heat transfer and phase equilibrium were included in the component models and chemical reaction balances were considered in the model of the combustion chamber. The system model has been validated with the test results and has consequently been used to predict the system performance at different operating and design conditions, such as varied ambient temperature, fuel flow rate and pressure ratio etc. The ultimate results of the performance analysis formulated by the system model can contribute significantly to the optimal component and system designs in various practical applications.

  13. Performance evaluation of a tri-generation system with simulation and experiment

    Energy Technology Data Exchange (ETDEWEB)

    Ge, Y.T.; Tassou, S.A.; Suguartha, N. [Mechanical Engineering, School of Engineering and Design, Brunel University, Uxbridge, Middlesex UB8 3PH (United Kingdom); Chaer, I. [Faculty of Engineering, Science and the Built Environment, London South Bank University (T617), Borough Road, London SE1 0AA (United Kingdom)

    2009-11-15

    A test rig for a tri-generation system was set up in the laboratory to investigate the system performance and application feasibility. The rig was composed of three modules, a power component containing a microturbine, a refrigeration unit consisting of an absorption chiller with gas pipe connection, and a supermarket section containing a display cabinet. This system was supposed to be effectively applied into a supermarket energy control system where cooling, heating and electricity power are simultaneously required and subsequently, valuable test results have been produced. In the mean time, a simulation model for the particular tri-generation system has been established by integrating the component models of the system in accordance with the components' actual flow paths and energy streams. These component models, which include a compressor, recuperator, combustion chamber, gas turbine, electric generator, gas pipes, generator (desorber), rectifier, absorbers, condenser and evaporator etc., were developed based upon the balance of heat and mass. The calculations of heat transfer and phase equilibrium were included in the component models and chemical reaction balances were considered in the model of the combustion chamber. The system model has been validated with the test results and has consequently been used to predict the system performance at different operating and design conditions, such as varied ambient temperature, fuel flow rate and pressure ratio etc. The ultimate results of the performance analysis formulated by the system model can contribute significantly to the optimal component and system designs in various practical applications. (author)

  14. Comparison of the performance of the next generation of optical interferometers

    Science.gov (United States)

    Pisani, Marco; Yacoot, Andrew; Balling, Petr; Bancone, Nicola; Birlikseven, Cengiz; Çelik, Mehmet; Flügge, Jens; Hamid, Ramiz; Köchert, Paul; Kren, Petr; Kuetgens, Ulrich; Lassila, Antti; Bartolo Picotto, Gian; Şahin, Ersoy; Seppä, Jeremias; Tedaldi, Matthew; Weichert, Christoph

    2012-08-01

    Six European National Measurement Institutes (NMIs) have joined forces within the European Metrology Research Programme funded project NANOTRACE to develop the next generation of optical interferometers having a target uncertainty of 10 pm. These are needed for NMIs to provide improved traceable dimensional metrology that can be disseminated to the wider nanotechnology community, thereby supporting the growth in nanotechnology. Several approaches were followed in order to develop the interferometers. This paper briefly describes the different interferometers developed by the various partners and presents the results of a comparison of performance of the optical interferometers using an x-ray interferometer to generate traceable reference displacements.

  15. Performance Analysis of Doubly Excited Brushless Generator with Outer Rotor for Wind Power Application

    Directory of Open Access Journals (Sweden)

    Yingchao Zhang

    2012-09-01

    Full Text Available In this paper, a novel doubly excited brushless generator (DEBG with outer radial laminated magnetic barrier rotor (RLMB-rotor for wind power application was designed and analyzed. The DEBG has 10 rotor pole numbers with outer rotor. Its performance is investigated using the 2D transient finite element method. The magnetic fields, torque capability, end winding voltage characteristics, radial magnetic force and energy efficiency were analyzed. All studies in this paper show that the simplicity, reliability, high efficiency and low vibration and noise of the DEBG with outer rotor are attractive for variable speed constant frequency (VSCF wind power generation system.

  16. A cooling concept for improved field winding performance in large superconducting ac generators

    International Nuclear Information System (INIS)

    Laskaris, T.E.

    1977-01-01

    An analytical study of a flow circuit for large superconducting generator rotors is presented. The flow circuit provides regulation of the level of liquid in the rotor externally by adjusting the helium supply pressure. It also protects the vapour cooled structural members of the rotor from overcooling during transient periods of operation. Furthermore, it is capable of reducing the winding temperature below 4.2 K thereby enhancing the superconductor's performance. For example, a large generator rotor with NbTi superconducting field winding experiences approximately a 50% increase in its critical current density compared to that at 4.2 K. (author)

  17. Numerical investigation of conjugate heat transfer and flow performance of a fin and tube heat exchanger with vortex generators

    DEFF Research Database (Denmark)

    Singh, Shobhana; Sørensen, Kim

    2017-01-01

    Vortex generator is considered as an effective device for augmentation of the thermal-hydraulic performance of a heat exchanger. The aim of present study is to examine the influence of vortex generators on a double fin and tube heat exchanger performance. Vortex generator of rectangular winglet...

  18. Makeup water system performance and impact on PWR steam generator corrosion

    International Nuclear Information System (INIS)

    Bell, M.J.; Sawocha, S.G.; Smith, L.A.

    1984-01-01

    The object of this EPRI-funded project was to assess the possible relation of pressurized water reactor (PWR) steam generator corrosion at fresh water sites to makeup water impurity ingress. Makeup water system design, operation and performance reviews were based on site visits, plant design documents, performance records and grab sample analyses. Design features were assessed in terms of their effect on makeup system performance. Attempts were made to correlate the makeup plant source water, system design characteristics, and typical makeup water qualities to steam generator corrosion observations, particularly intergranular attack (IGA). Direct correlations were not made since many variables are involved in the corrosion process and in the case of IGA, the variables have not been clearly established. However, the study did demonstrate that makeup systems can be a significant source of contaminants that are suspected to lead to both IGA and denting. Additionally, it was noted that typical makeup system performance with respect to organic removal was not good. The role of organics in steam generator damage has not been quantified and may deserve further study

  19. High-performance ferroelectric and magnetoresistive materials for next-generation thermal detector arrays

    Science.gov (United States)

    Todd, Michael A.; Donohue, Paul P.; Watton, Rex; Williams, Dennis J.; Anthony, Carl J.; Blamire, Mark G.

    2002-12-01

    This paper discusses the potential thermal imaging performance achievable from thermal detector arrays and concludes that the current generation of thin-film ferroelectric and resistance bolometer based detector arrays are limited by the detector materials used. It is proposed that the next generation of large uncooled focal plane arrays will need to look towards higher performance detector materials - particularly if they aim to approach the fundamental performance limits and compete with cooled photon detector arrays. Two examples of bolometer thin-film materials are described that achieve high performance from operating around phase transitions. The material Lead Scandium Tantalate (PST) has a paraelectric-to-ferroelectric phase transition around room temperature and is used with an applied field in the dielectric bolometer mode for thermal imaging. PST films grown by sputtering and liquid-source CVD have shown merit figures for thermal imaging a factor of 2 to 3 times higher than PZT-based pyroelectric thin films. The material Lanthanum Calcium Manganite (LCMO) has a paramagnetic to ferromagnetic phase transition around -20oC. This paper describes recent measurements of TCR and 1/f noise in pulsed laser-deposited LCMO films on Neodymium Gallate substrates. These results show that LCMO not only has high TCR's - up to 30%/K - but also low 1/f excess noise, with bolometer merit figures at least an order of magnitude higher than Vanadium Oxide, making it ideal for the next generation of microbolometer arrays. These high performance properties come at the expense of processing complexities and novel device designs will need to be introduced to realize the potential of these materials in the next generation of thermal detectors.

  20. Performance of OSC's initial Amtec generator design, and comparison with JPL's Europa Orbiter goals

    International Nuclear Information System (INIS)

    Schock, A.; Noravian, H.; Or, C.; Kumar, V.

    1998-01-01

    The procedure for the analysis (with overpotential correction) of multitube AMTEC (Alkali Metal Thermal-to-Electrical Conversion) cells described in Paper IECEC 98-243 was applied to a wide range of multicell radioisotope space power systems. System design options consisting of one or two generators, each with 2, 3, or 4 stacked GPHS (General Purpose Heat Source) modules, identical to those used on previous NASA missions, were analyzed and performance-mapped. The initial generators analyzed by OSC had 8 AMTEC cells on each end of the heat source stack, with five beta-alumina solid electrolyte (BASE) tubes per cell. The heat source and converters in the Orbital generator designs are embedded in a thermal insulation system consisting of Min-K fibrous insulation surrounded by graded-length molybdenum multifoils. Detailed analyses in previous Orbital studies found that such an insulation system could reduce extraneous heat losses to about 10%. For the above design options, the present paper presents the system mass and performance (i.e., the EOM system efficiency and power output and the BOM evaporator and clad temperatures) for a wide range of heat inputs and load voltages, and compares the results with JPL's preliminary goals for the Europa Orbiter mission to be launched in November 2003. The analytical results showed that the initial 16-cell generator designs resulted in either excessive evaporator and clad temperatures and/or insufficient power outputs to meet the JPL-specified mission goals. The computed performance of modified OSC generators with different numbers of AMTEC cells, cell diameters, cell lengths, cell materials, BASE tube lengths, and number of tubes per cell are described in Paper IECEC.98.245 in these proceedings

  1. Operational performance of the Avispa-IIE wind generator in microhybrid systems

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez Galarza, Raul; Mejia Neri, Fortino [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1997-12-31

    The purpose of this paper is to make a general analysis over the operational performance of the Avispa-IIE wind generator in an Solar-Eolic hybrid installation, at an eco-tourist resort. This work was performed through the monitor of the wind generator and the system itself throughout a year, for the acquisition taking the variables of interest and operational parameters that might allow to characterize and to evaluate the general behavior of the system. Herein are the principals characteristics of the wind generator; its performance curve, the basic configuration of the installation and the control philosophy; Likewise, some technical and human problems which arise during the operation of the system are included, the implementation of improvements in the wind generator and the general results acquired during the time of operation of the wind generator in the cited installations. [Espanol] El proposito de este articulo es el hacer un analisis general del comportamiento operacional del aerogenerador Avispa-IIE en una instalacion hibrida Solar-Eolica en un lugar de veraneo eco-turistico. Este trabajo ha sido llevado a cabo mediante el monitor del aerogenerador y el sistema mismo por espacio de un ano, para la adquisicion de las variables de interes y de los parametros operacionales que pudieran servir para caracterizar y evaluar el comportamiento general del sistema. Aqui se incluyen las caracteristicas principales del aerogenerador; su curva de comportamiento, la configuracion basica de la instalacion y la filosofia del control. De la misma manera se incluyen algunos problemas tecnicos y humanos que se originan durante la operacion del sistema y la puesta en practica de las mejoras del aerogenerador y los resultados generales adquiridos durante el tiempo de operacion del aerogenerador en las instalaciones citadas.

  2. Operational performance of the Avispa-IIE wind generator in microhybrid systems

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez Galarza, Raul; Mejia Neri, Fortino [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1998-12-31

    The purpose of this paper is to make a general analysis over the operational performance of the Avispa-IIE wind generator in an Solar-Eolic hybrid installation, at an eco-tourist resort. This work was performed through the monitor of the wind generator and the system itself throughout a year, for the acquisition taking the variables of interest and operational parameters that might allow to characterize and to evaluate the general behavior of the system. Herein are the principals characteristics of the wind generator; its performance curve, the basic configuration of the installation and the control philosophy; Likewise, some technical and human problems which arise during the operation of the system are included, the implementation of improvements in the wind generator and the general results acquired during the time of operation of the wind generator in the cited installations. [Espanol] El proposito de este articulo es el hacer un analisis general del comportamiento operacional del aerogenerador Avispa-IIE en una instalacion hibrida Solar-Eolica en un lugar de veraneo eco-turistico. Este trabajo ha sido llevado a cabo mediante el monitor del aerogenerador y el sistema mismo por espacio de un ano, para la adquisicion de las variables de interes y de los parametros operacionales que pudieran servir para caracterizar y evaluar el comportamiento general del sistema. Aqui se incluyen las caracteristicas principales del aerogenerador; su curva de comportamiento, la configuracion basica de la instalacion y la filosofia del control. De la misma manera se incluyen algunos problemas tecnicos y humanos que se originan durante la operacion del sistema y la puesta en practica de las mejoras del aerogenerador y los resultados generales adquiridos durante el tiempo de operacion del aerogenerador en las instalaciones citadas.

  3. Performance assessment of hybrid power generation systems: Economic and environmental impacts

    International Nuclear Information System (INIS)

    Al-Sharafi, Abdullah; Yilbas, Bekir S.; Sahin, Ahmet Z.; Ayar, T.

    2017-01-01

    Highlights: • A double-step optimization tool for hybrid power generation systems is introduced. • Economical aspects and the impact of the system on the environment are considered. • A hybrid system comprises PV array-wind turbine-battery-diesel engine is considered. • Real time analysis of the system for full year simulation is carried out. • System optimum configuration at point where total performance index is maximized. - Abstract: This article aims to introduce a double-step performance assessment tool for the hybrid power generation systems. As a case study, a hybrid system comprising PV array, wind-turbine, battery bank and diesel engine is incorporated in hourly based simulations to meet power demand of a residence unit at Dhahran area, Kingdom of Saudi Arabia. Different indicators related to economical and environmental performance assessments of the hybrid system have been considered. In the economic related assessment case, cost of electricity, energy excess percentage, and operating life cycle indicators have been considered and combined to develop the first overall performance index. Renewable contribution, renewable source availability and environmental impact indicators have been considered for the environmental assessment case and they are combined in the second performance index. For either economical or environmental cases, the optimum configuration of the system is achieved by maximizing the first and second overall performance indicators. This innovative optimization tools gives the designer the freedom to assign suitable weights associated with economical aspect, environmental impact, governmental regulations and social impact, for the first and second overall performance indicators, and combine them in the total performance index. The optimum system configuration is at the point where the total performance index is maximized.

  4. Performance tests on new chromatographic material for 99Mo-99mTc generators

    International Nuclear Information System (INIS)

    Sombrito, Elvira Z.; Bulos, Adelina D.M.

    2004-01-01

    Technetium-99m continues to be the main workhorse of nuclear medicine in the Philippines. Almost 13TBq of 99m Tc was imported to the country in 2002 supplied as 99m Tc- 99 Mo generators. These generators make use of fission molybdenum adsorbed onto an alumina column. Problems associated with the alumina chromatographic generators arise due to safety and economic issues that would be remedied by gel-type generators using low specific activity reactor-produced molybdenum-99 adsorbed on a high capacity gel column material. The Philippine Nuclear Research Institute (PNRI) exerted efforts in this direction by developing a gel-type column, which showed satisfactory molybdenum adsorptive capacity. Likewise, Kaken Co. in Japan in cooperation with Japan Atomic Energy Research Institute (JAERI) developed a dried form of a gel-type polyzirconium compound (PZC). It is a ready-to-use high molybdenum capacity column material for adsorbing reactor-produced molybedum-99. The performance of this material is being tested under the framework of the FNCA project on Research Reactor Utilization. Performance tests on four batches of PZC were performed using fission molybdenum eluted from a 99 Mo- 99m Tc generator. A total of 3.3 GBq 99 Mo was extracted from an alumina column of a commercial generator and mixed with carrier molybdenum solution. About 0.67 GBq was loaded into each of the 12 x 90 mm column. One batch was prepared and distributed in 1999 and tests showed very poor elution yield of 30%. Three recent batches of PZC (2002) gave elution yields of 71% (Range of 69-75). The adsorptive capacity is 99% with about 4% desorption rate. Elution volume is at 5-6 ml. Daily elution for five days gave from 1.6 to 5.5% variability. The tests were performed all at the same time and a trend of improving elution yield and consistency of daily elution yield was observed with the time of testing nearer to the sample preparation date. X-ray diffraction analysis showed an amorphous structure for

  5. Long-term damage management strategies for optimizing steam generator performance

    International Nuclear Information System (INIS)

    Egan, G.R.; Besuner, P.M.; Fox, J.H.; Merrick, E.A.

    1991-01-01

    Minimizing long-term impact of steam generator operating, maintenance, outage, and replacement costs is the goal of all pressurized water reactor utilities. Recent research results have led to deterministic controls that may be implemented to optimize steam generator performance and to minimize damage accumulation. The real dilemma that utilities encounter is the decision process that needs to be made in the face of uncertain data. Some of these decisions involve the frequency and extent of steam generator eddy current tube inspections; the definition of operating conditions to minimize the rate of corrosion reactions (T (hot) , T (cold) ; and the imposition of strict water quality management guidelines. With finite resources, how can a utility decide which damage management strategy provides the most return for its investment? Aptech Engineering Services, Inc. (APTECH) developed a damage management strategy that starts from a deterministic analysis of a current problem- primary water stress corrosion cracking (PWSCC). The strategy involves a probabilistic treatment that results in long-term performance optimization. By optimization, we refer to minimizing the total cost of operating the steam generator. This total includes the present value costs of operations, maintenance, outages, and replacements. An example of the application of this methodology is presented. (author)

  6. Dramatic improvement of membrane performance for microalgae harvesting with a simple bubble-generator plate.

    Science.gov (United States)

    Hwang, Taewoon; Oh, You-Kwan; Kim, Bohwa; Han, Jong-In

    2015-06-01

    To overcome fouling issue in membrane-based algae harvesting and thus make an otherwise promising harvesting option more competitive, a bubble-generator plate was developed. According to computational fluid dynamics analysis, the plate generated substantial hydrodynamic power in terms of high pressure, velocity, and shear stress. When installed in a membrane filtration system with membranes of different surface and structural characteristics (one prepared by the phase inversion method, and a commercial one) the bubble-generator was indeed effective in reducing fouling. Without the plate, the much cheaper homemade membrane had the similar performance as the commercial one. Use of the bubble-generator considerably improved the performance of both membranes, and revealed a valuable synergy with the asymmetrical structure of the homemade membrane. This result clearly showed that the ever-problematic fouling could be mitigated in a rather easy manner, and in so doing, that membrane technology could indeed become a practical option for algae harvesting. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Performance of a 3 kW wind turbine generator with variable pitch control system

    International Nuclear Information System (INIS)

    Nagai, Baku M.; Ameku, Kazumasa; Roy, Jitendro Nath

    2009-01-01

    A prototype 3 kW horizontal upwind type wind turbine generator of 4 m in diameter has been designed and examined under real wind conditions. The machine was designed based on the concept that even small wind turbines should have a variable pitch control system just as large wind turbines, especially in Japan where typhoons occur at least once a year. A characteristic of the machine is the use of a worm and gear system with a stepping motor installed in the center of the hub, and the rotational main shaft. The machine is constructed with no mechanical breaking system so as to avoid damage from strong winds. In a storm, the wind turbine is slowed down by adjusting the pitch angle and the maximum electrical load. Usually the machine is controlled at several stages depending on the rotational speed of the blades. Two control methods have been applied: the variable pitch angle, and regulation of the generator field current. The characteristics of the generator under each rotational speed and field current are first investigated in the laboratory. This paper describes the performances of the wind turbine in terms of the functions of wind turbine rotational speed, generated outputs, and its stability for wind speed changes. The expected performances of the machine have been confirmed under real wind conditions and compared with numerical simulation results. The wind turbine showed a power coefficient of 0.257 under the average wind speed of 7.3 m/s.

  8. Corrosion Performance of New Generation Aluminum-Lithium Alloys for Aerospace Applications

    Science.gov (United States)

    Moran, James P.; Bovard, Francine S.; Chrzan, James D.; Vandenburgh, Peter

    Over the past several years, a new generation of aluminum-lithium alloys has been developed. These alloys are characterized by excellent strength, low density, and high modulus of elasticity and are therefore of interest for lightweight structural materials applications particularly for construction of current and future aircraft. These new alloys have also demonstrated significant improvements in corrosion resistance when compared with the legacy and incumbent alloys. This paper documents the superior corrosion resistance of the current commercial tempers of these materials and also discusses the corrosion performance as a function of the degree of artificial aging. Results from laboratory corrosion tests are compared with results from exposures in a seacoast atmosphere to assess the predictive capability of the laboratory tests. The correlations that have been developed between the laboratory tests and the seacoast exposures provide confidence that a set of available methods can provide an accurate assessment of the corrosion performance of this new generation of alloys.

  9. Effect of excess air on second-generation PFB combustion plant performance and economics

    International Nuclear Information System (INIS)

    Robertson, A.; Garland, R.; Newby, R.; Rehmat, A.; Rubow, L.; Bonk, D.

    1990-01-01

    This paper presents a conceptual design of a 1.4-MPa (14-atm) coal-fired second-generation pressurized fluidized bed (PFB) combustion plant and identifies the performance and economic changes that result as the excess air and thus gas turbine-to-steam turbine power ratio, is changed. The performance of these plants, another second- generation PFB combustion plant, and a conventional pulverized-coal (PC)-fired plant with wet limestone flue gas desulfurization is compared. Depending upon the conditions selected, the PFB combustion plant can achieve a 45 percent efficiency (based on the higher heating value of the coal used as fuel) and a cost of electricity at least 20 percent lower than that of the conventional PC-fired plant

  10. Performance Limiting Effects in Power Generation from Salinity Gradients by Pressure Retarded Osmosis

    KAUST Repository

    Yip, Ngai Yin

    2011-12-01

    Pressure retarded osmosis has the potential to utilize the free energy of mixing when fresh river water flows into the sea for clean and renewable power generation. Here, we present a systematic investigation of the performance limiting phenomena in pressure retarded osmosis-external concentration polarization, internal concentration polarization, and reverse draw salt flux-and offer insights on the design criteria of a high performance pressure retarded osmosis power generation system. Thin-film composite polyamide membranes were chemically modified to produce a range of membrane transport properties, and the water and salt permeabilities were characterized to determine the underlying permeability-selectivity trade-off relationship. We show that power density is constrained by the trade-off between permeability and selectivity of the membrane active layer. This behavior is attributed to the opposing influence of the beneficial effect of membrane water permeability and the detrimental impact of reverse salt flux coupled with internal concentration polarization. Our analysis reveals the intricate influence of active and support layer properties on power density and demonstrates that membrane performance is maximized by tailoring the water and salt permeabilities to the structural parameters. An analytical parameter that quantifies the relative influence of each performance limiting phenomena is employed to identify the dominant effect restricting productivity. External concentration polarization is shown to be the main factor limiting performance at high power densities. Enhancement of the hydrodynamic flow conditions in the membrane feed channel reduces external concentration polarization and thus, yields improved power density. However, doing so will also incur additional operating costs due to the accompanying hydraulic pressure loss. This study demonstrates that by thoughtful selection of the membrane properties and hydrodynamic conditions, the detrimental

  11. Steam-generator tube performance: world experience with water-cooled nuclear power reactors during 1978

    International Nuclear Information System (INIS)

    Tatone, O.S.; Pathania, R.S.

    1980-01-01

    The performance of steam-generator tubes in water-cooled nuclear power reactors during 1978 is reviewed. Tube failures occurred at 31 of the 86 reactors surveyed. The causes of these failures and the procedures designed to deal with them are described. The number of tubes plugged has decreased dramatically in 1978 compared to the previous year. This is attributed to the diligent application of techniques developed through in-plant experience and research and development programs over the past several years

  12. Analysis of Wind Speed Forecasting Error Effects on Automatic Generation Control Performance

    Directory of Open Access Journals (Sweden)

    H. Rajabi Mashhadi

    2014-09-01

    Full Text Available The main goal of this paper is to study statistical indices and evaluate AGC indices in power system which has large penetration of the WTGs. Increasing penetration of wind turbine generations, needs to study more about impacts of it on power system frequency control. Frequency control is changed with unbalancing real-time system generation and load . Also wind turbine generations have more fluctuations and make system more unbalance. Then AGC loop helps to adjust system frequency and the scheduled tie-line powers. The quality of AGC loop is measured by some indices. A good index is a proper measure shows the AGC performance just as the power system operates. One of well-known measures in literature which was introduced by NERC is Control Performance Standards(CPS. Previously it is claimed that a key factor in CPS index is related to standard deviation of generation error, installed power and frequency response. This paper focuses on impact of a several hours-ahead wind speed forecast error on this factor. Furthermore evaluation of conventional control performances in the power systems with large-scale wind turbine penetration is studied. Effects of wind speed standard deviation and also degree of wind farm penetration are analyzed and importance of mentioned factor are criticized. In addition, influence of mean wind speed forecast error on this factor is investigated. The study system is a two area system which there is significant wind farm in one of those. The results show that mean wind speed forecast error has considerable effect on AGC performance while the mentioned key factor is insensitive to this mean error.

  13. Steam generator tube performance: experience with water-cooled nuclear power reactors during 1977

    International Nuclear Information System (INIS)

    Pathania, R.S.; Tatone, O.S.

    1979-02-01

    The performance of steam generator tubes in water-cooled nuclear power reactors has been reviewed for 1977. Failures were reported in 34 of the 79 reactors surveyed. Causes of these failures and inspection and repair procedures designed to deal with them are presented. Although corrosion remained the leading cause of tube failures, specific mechanisms have been identified and methods of dealing with them developed. These methods are being applied and should lead to a reduction of corrosion failures in future. (author)

  14. Wind Turbine Generator System Power Performance Test Report for the ARE442 Wind Turbine

    Energy Technology Data Exchange (ETDEWEB)

    van Dam, J.; Jager, D.

    2010-02-01

    This report summarizes the results of a power performance test that NREL conducted on the ARE 442 wind turbine. This test was conducted in accordance with the International Electrotechnical Commission's (IEC) standard, Wind Turbine Generator Systems Part 12: Power Performance Measurements of Electricity Producing Wind Turbines, IEC 61400-12-1 Ed.1.0, 2005-12. However, because the ARE 442 is a small turbine as defined by IEC, NREL also followed Annex H that applies to small wind turbines. In these summary results, wind speed is normalized to sea-level air density.

  15. Performance augmentation with vortex generators: Design and testing for stall-regulated AWT-26 turbine

    Energy Technology Data Exchange (ETDEWEB)

    Griffin, D.A. [Advanced Wind Turbines Inc., Seattle, WA (United States)

    1996-12-31

    A study investigated the use of vortex generators (VGs) for performance augmentation of the stall-regulated AWT-26 wind turbine. Based on wind-tunnel results and analysis, a VG array was designed for and tested on the AWT-26 prototype, designated Pt. Performance and loads data were measured for P1, both with and without VGs installed. The turbine performance with VGs met most of the design requirements; power output was increased at moderate wind speeds with a minimal effect on peak power. However, VG drag penalties caused a loss in power output for low wind speeds, such that performance with VGs resulted in a net decrease in AEP for wind speed sites up to 8.5 m/s. 8 refs., 8 figs., 3 tabs.

  16. Artificial Bee Colony Algorithm for Transient Performance Augmentation of Grid Connected Distributed Generation

    Science.gov (United States)

    Chatterjee, A.; Ghoshal, S. P.; Mukherjee, V.

    In this paper, a conventional thermal power system equipped with automatic voltage regulator, IEEE type dual input power system stabilizer (PSS) PSS3B and integral controlled automatic generation control loop is considered. A distributed generation (DG) system consisting of aqua electrolyzer, photovoltaic cells, diesel engine generator, and some other energy storage devices like flywheel energy storage system and battery energy storage system is modeled. This hybrid distributed system is connected to the grid. While integrating this DG with the onventional thermal power system, improved transient performance is noticed. Further improvement in the transient performance of this grid connected DG is observed with the usage of superconducting magnetic energy storage device. The different tunable parameters of the proposed hybrid power system model are optimized by artificial bee colony (ABC) algorithm. The optimal solutions offered by the ABC algorithm are compared with those offered by genetic algorithm (GA). It is also revealed that the optimizing performance of the ABC is better than the GA for this specific application.

  17. Performance Evaluation on Otto Engine Generator Using Gasoline and Biogas from Palm Oil Mill Effluent

    Science.gov (United States)

    Irvan; Trisakti, B.; Husaini, T.; Sitio, A.; Sitorus, TB

    2017-06-01

    Biogas is a flammable gas produced from the fermentation of organic materials by anaerobic bacteria originating from household waste manure and organic waste including palm oil mill effluent (POME). POME is mainly discharged from the sterilization unit of palm oil processing into crude palm oil. This study utilized biogas produced from liquid waste palm oil for use as fuel in the Otto engine generator 4 - stroke, type STARKE GFH1900LX with a peak power of 1.3 kW, 1.0 kW average power, bore 55 mm, stroke 40 mm, Vd 95 × 10-6 m3, Vc 10 × 10-6 m3, compression ratio of 10.5 : 1, and the number of cylinders = 1. The objective of this study is to evaluate the performance of Otto engine generator fueled with biogas that generated from POME, then comparing its performance fueled by gasoline. The performance included power, torque, specific fuel consumption, thermal efficiency, and the air-fuel ratio. Experiment was conducted by using a variation of the lamp load of 100, 200, 300, 400, and 500 W. The results revealed that the use of biogas as fuel decreased in power, torque, brake thermal efficiency, and air fuel ratio (AFR), while there is an increasing of value specific fuel consumption (SFC).

  18. A formalism to generate probability distributions for performance-assessment modeling

    International Nuclear Information System (INIS)

    Kaplan, P.G.

    1990-01-01

    A formalism is presented for generating probability distributions of parameters used in performance-assessment modeling. The formalism is used when data are either sparse or nonexistent. The appropriate distribution is a function of the known or estimated constraints and is chosen to maximize a quantity known as Shannon's informational entropy. The formalism is applied to a parameter used in performance-assessment modeling. The functional form of the model that defines the parameter, data from the actual field site, and natural analog data are analyzed to estimate the constraints. A beta probability distribution of the example parameter is generated after finding four constraints. As an example of how the formalism is applied to the site characterization studies of Yucca Mountain, the distribution is generated for an input parameter in a performance-assessment model currently used to estimate compliance with disposal of high-level radioactive waste in geologic repositories, 10 CFR 60.113(a)(2), commonly known as the ground water travel time criterion. 8 refs., 2 figs

  19. Performance Investigation of an Exhaust Thermoelectric Generator for Military SUV Application

    Directory of Open Access Journals (Sweden)

    Rui Quan

    2018-01-01

    Full Text Available To analyze the thermoelectric power generation for sports utility vehicle (SUV application, a novel thermoelectric generator (TEG based on low-temperature Bi2Te3 thermoelectric modules (TEMs and a chaos-shaped brass heat exchanger is constructed. The temperature distribution of the TEG is analyzed based on an experimental setup, and the temperature uniformity optimization method is performed by chipping peak off and filling valley is taken to validate the improved output power. An automobile exhaust thermoelectric generator (AETEG using four TEGs connected thermally in parallel and electrically in series is assembled into a prototype military SUV, its temperature distribution, output voltage, output power, system efficiency, inner resistance, and backpressure is analyzed, and several important influencing factors such as vehicle speed, clamping pressure, engine coolant flow rate, and ambient temperature on its output performance are tested. Experimental results demonstrate that higher vehicle speed, larger clamping pressure, faster engine coolant flow rate and lower ambient temperature can enhance the overall output performance, but the ambient temperature and coolant flow rate are less significant. The maximum output power of AETEG is 646.26 W, the corresponding conversion efficiency is 1.03%, and the increased backpressure changes from 1681 Pa to 1807 Pa when the highest vehicle speed is 125 km/h.

  20. Parameterization experiments performed via synthetic mass movements prototypes generated by 3D slope stability simulator

    Science.gov (United States)

    Colangelo, Antonio C.

    2010-05-01

    The central purpose of this work is to perform a reverse procedure in the mass movement conventional parameterization approach. The idea is to generate a number of synthetic mass movements by means of the "slope stability simulator" (Colangelo, 2007), and compeer their morphological and physical properties with "real" conditions of effective mass movements. This device is an integrated part of "relief unity emulator" (rue), that permits generate synthetic mass movements in a synthetic slope environment. The "rue" was build upon fundamental geomorphological concepts. These devices operate with an integrated set of mechanical, geomorphic and hydrological models. The "slope stability simulator" device (sss) permits to perform a detailed slope stability analysis in a theoretical three dimensional space, by means of evaluation the spatial behavior of critical depths, gradients and saturation levels in the "potential rupture surfaces" inferred along a set of slope profiles, that compounds a synthetic slope unity. It's a meta-stable 4-dimensional object generated by means of "rue", that represents a sequence evolution of a generator profile applied here, was adapted the infinite slope model for slope. Any slope profiles were sliced by means of finite element solution like in Bishop method. For the synthetic slope systems generated, we assume that the potential rupture surface occurs at soil-regolith or soil-rock boundary in slope material. Sixteen variables were included in the "rue-sss" device that operates in an integrated manner. For each cell, the factor of safety was calculated considering the value of shear strength (cohesion and friction) of material, soil-regolith boundary depth, soil moisture level content, potential rupture surface gradient, slope surface gradient, top of subsurface flow gradient, apparent soil bulk density and vegetation surcharge. The slope soil was considered as cohesive material. The 16 variables incorporated in the models were analyzed for

  1. Design and performance of BWC replacement steam generators for PWR systems

    Energy Technology Data Exchange (ETDEWEB)

    Klarner, R.; Steinmoeller, F.; Millman, J.; Schneider, W. [Babcock and Wilcox Canada, Cambridge, Ontario (Canada)

    1998-07-01

    In recent years, Babcock and Wilcox Canada (BWC) has provided a number of PWR Replacement Steam Generators (RSGS) to replace units that had experienced extensive Alloy 600 tube degradation. BWC RSG units are in operation at Northeast Utilities' Millstone Unit 2, Rochester Gas and Electric's Ginna Station, Duke Energy's Catawba Unit 1, McGuire Unit 1 and 2, Florida Power and Light's St. Lucie Unit 1 and Commonwealth Edison's Byron 1 Station. Extensive start-up performance characteristics have been obtained for Millstone 2, Ginna, McGuire 1, and Catawba 1 RSGS. The Millstone 2, Ginna and Catawba 1 RSGs have also undergone extensive inspections following their first cycle of operation. The design and start-up performance characteristics of these RSGs are presented. The BWC Replacement Steam generators were designed to fit the existing envelope of pressure boundary dimensions to ensure licensability and integration into the Nuclear Steam Supply System. The RSGs were provided with a tube bundle of Alloy 690TT tubing, sized to match or exceed the original steam generator (OSG) thermal performance including provision for the reduced thermal conductivity of Alloy 690 relative to Alloy 600. The RSG tube bundle configurations provide a higher circulation design relative to the OSG, and feature corrosion resistant lattice grid and U-bend tube supports which provide effective anti-vibration support. The tube bundle supports accommodate relatively unobstructed flow and allow unrestrained structural interactions during thermal transients. Efficient steam separators assure low moisture carryover as well as high circulation. Performance measurements obtained during start-up verify that the BWC RSGs meet or exceed the specified thermal and moisture carryover performance requirements. RSG water level stability results at nor-mal operation and during plant transients have been excellent. Visual and ECT inspections have confirmed minimal deposition and 100

  2. Design and performance of BWC replacement steam generators for PWR systems

    International Nuclear Information System (INIS)

    Klarner, R.; Steinmoeller, F.; Millman, J.; Schneider, W.

    1998-01-01

    In recent years, Babcock and Wilcox Canada (BWC) has provided a number of PWR Replacement Steam Generators (RSGS) to replace units that had experienced extensive Alloy 600 tube degradation. BWC RSG units are in operation at Northeast Utilities' Millstone Unit 2, Rochester Gas and Electric's Ginna Station, Duke Energy's Catawba Unit 1, McGuire Unit 1 and 2, Florida Power and Light's St. Lucie Unit 1 and Commonwealth Edison's Byron 1 Station. Extensive start-up performance characteristics have been obtained for Millstone 2, Ginna, McGuire 1, and Catawba 1 RSGS. The Millstone 2, Ginna and Catawba 1 RSGs have also undergone extensive inspections following their first cycle of operation. The design and start-up performance characteristics of these RSGs are presented. The BWC Replacement Steam generators were designed to fit the existing envelope of pressure boundary dimensions to ensure licensability and integration into the Nuclear Steam Supply System. The RSGs were provided with a tube bundle of Alloy 690TT tubing, sized to match or exceed the original steam generator (OSG) thermal performance including provision for the reduced thermal conductivity of Alloy 690 relative to Alloy 600. The RSG tube bundle configurations provide a higher circulation design relative to the OSG, and feature corrosion resistant lattice grid and U-bend tube supports which provide effective anti-vibration support. The tube bundle supports accommodate relatively unobstructed flow and allow unrestrained structural interactions during thermal transients. Efficient steam separators assure low moisture carryover as well as high circulation. Performance measurements obtained during start-up verify that the BWC RSGs meet or exceed the specified thermal and moisture carryover performance requirements. RSG water level stability results at nor-mal operation and during plant transients have been excellent. Visual and ECT inspections have confirmed minimal deposition and 100% tube integrity following

  3. Performance Evaluation of a Printed Circuit Steam Generator for Integral Reactors: A Feasibility Test

    Energy Technology Data Exchange (ETDEWEB)

    Han, Hun Sik; Kang, Han-Ok; Yoon, Juhyeon; Kim, Young In; Kim, Keung Koo [KAERI, Daejeon (Korea, Republic of); Seo, Jang-won; Choi, Brain [Alfa Laval Korea Ltd., Daejeon (Korea, Republic of)

    2015-05-15

    SMART (System-integrated Modular Advanced ReacTor) is a small-sized integral type pressurized water reactor. It adopts advanced design features such as structural safety improvement, system simplification, and component modularization to achieve highly enhanced safety and improved economics. The design issues related to further safety enhancement and cost reduction have received significant attention to increase its competitiveness in the global small reactor market. For the cost reduction, it is important to design the reactor vessel as small as possible. Thus, it is necessary to reduce the volume of main components such as a steam generator. Its manufacturing processes of the chemical etching and diffusion bonding provide high effectiveness, high compactness, and inherent structural safety under high temperatures and high pressures. Thus, it is expected to be an alternative to the conventional shell and tube type steam generator in SMART. In this paper, simple thermal-hydraulic performance measurement of a small-scale printed circuit steam generator (PCSG) is conducted to investigate the feasibility of applying it to SMART. The simple thermal-hydraulic performance of the PCSG has been experimentally evaluated. A small-scale PCHE is employed to investigate the feasibility of operating it as a steam generator. The performance assessment reveals that the PCSG stably produces superheated steam, and the increased degree of superheat is obtained at lower water flow rate. However, the flow instability is increased with the decrease of the water flow rate. Thus, it is required to apply the orifice design into the cold side plate to suppress the density-wave oscillations. The pressure drops and heat transfer rates increase with the water flow rate.

  4. Thermodynamic performance optimization of the absorption-generation process in an absorption refrigeration cycle

    International Nuclear Information System (INIS)

    Chen, Yi; Han, Wei; Jin, Hongguang

    2016-01-01

    Highlights: • This paper proposes a new thermal compressor model with boost pressure ratio. • The proposed model is an effective way to optimize the absorption-generation process. • Boost pressure ratio is a key parameter in the proposed thermal compressor model. • The optimum boost pressure ratios for two typical refrigeration systems are obtained. - Abstract: The absorption refrigeration cycle is a basic cycle that establishes the systems for utilizing mid-low temperature heat sources. A new thermal compressor model with a key parameter of boost pressure ratio is proposed to optimize the absorption-generation process. The ultimate generation pressure and boost pressure ratio are used to represent the potential and operating conditions of the thermal compressor, respectively. Using the proposed thermal compressor model, the operation mechanism and requirements of the absorption refrigeration system and absorption-compression refrigeration system are elucidated. Furthermore, the two typical heat conversion systems are optimized based on the thermal compressor model. The optimum boost pressure ratios of the absorption refrigeration system and the absorption-compression refrigeration system are 0.5 and 0.75, respectively. For the absorption refrigeration system, the optimum generation temperature is 125.31 °C at the cooling water temperature of 30 °C, which is obtained by simple thermodynamic calculation. The optimized thermodynamic performance of the absorption-compression refrigeration system is 16.7% higher than that of the conventional absorption refrigeration system when the generation temperature is 100 °C. The thermal compressor model proposed in this paper is an effective method for simplifying the optimization of the thermodynamic systems involving an absorption-generation process.

  5. A review on heat sink for thermo-electric power generation: Classifications and parameters affecting performance

    International Nuclear Information System (INIS)

    Elghool, Ali; Basrawi, Firdaus; Ibrahim, Thamir Khalil; Habib, Khairul; Ibrahim, Hassan; Idris, Daing Mohamad Nafiz Daing

    2017-01-01

    Highlights: • Coupling a thermoelectric power generation (TEG) to a heat sink is presented. • Review the classifications and parameters affecting performance of the TEG with heat sink. • Discuss different mathematical models of the heat sinks. • The passive heat sinks are most appropriate because of the inherent efficiency of TEG. • Medium temperature range below 300 °C is found to be most suitable for HPHS. - Abstract: In recent years, there have been growing interests in key areas related to global warming resulting from environmental emissions, and the diminishing sources of fossil fuel. The increased interest has led to significant research efforts towards finding novel technologies in clean energy production. Consequently, the merits of a thermo-electric generator (TEG) have promised a revival of alternative means of producing green energy. It is, however, impractical to account for the cost of thermal energy input to the TEG which is in the form of final waste heat. This is because the technology presents critical limitations in determining its cost efficiency nor its economic disadvantages. This paper reviews the principles of thermo-electric power production, as well the materials use, performance achieved, and application areas. The paper also takes a particular deliberation on TEG heat sinks geometries and categories. The review emphasizes more on the TEG performance while considering a number of heat sink parameters related to its performance.

  6. Improving large class performance and engagement through student-generated question banks.

    Science.gov (United States)

    Hancock, Dale; Hare, Nicole; Denny, Paul; Denyer, Gareth

    2018-03-12

    Disciplines such as Biochemistry and Molecular Biology, which involve concepts not included in the high-school curriculum, are very challenging for many first year university students. These subjects are particularly difficult for students accustomed to surface learning strategies involving memorization and recall of facts, as a deeper understanding of the relationship between concepts is needed for successful transfer to related areas and subsequent study. In this article, we explore an activity in a very large first year Molecular Biology course, in which students create multiple-choice questions related to targeted learning outcomes, and then answer and evaluate one another's questions. This activity encompasses elements of both self- and peer-assessment and the generative tasks of creating questions and producing written feedback may contribute to a deeper understanding of the material. We make use of a free online platform to facilitate all aspects of the process and analyze the effect of student engagement with the task on overall course performance. When compared to previous semester's cohorts, we observe a pronounced improvement in class performance on exam questions targeting similar concepts to the student-generated questions. In addition, those students that engage to a greater extent with the activity perform significantly better on the targeted exam questions than those who are less active, yet all students perform similarly on a set of isolated control questions appearing on the same exam. © 2018 by The International Union of Biochemistry and Molecular Biology, 2018. © 2018 The International Union of Biochemistry and Molecular Biology.

  7. A global fouling factor methodology for analyzing steam generator thermal performance degradation

    International Nuclear Information System (INIS)

    Kreider, M.A.; White, G.A.; Varrin, R.D. Jr.

    1998-06-01

    Over the past few years, steam generator (SG) thermal performance degradation has led to decreased plant efficiency and power output at numerous PWR nuclear power plants with recirculating-type SGs. The authors have developed and implemented methodologies for quantitatively evaluating the various sources of SG performance degradation, both internal and external to the SG pressure boundary. These methodologies include computation of the global fouling factor history, evaluation of secondary deposit thermal resistance using deposit characterization data, and consideration of pressure loss causes unrelated to the tube bundle, such as hot-leg temperature streaming and SG moisture separator fouling. In order to evaluate the utility of the global fouling factor methodology, the authors performed case studies for a number of PWR SG designs. Key results from two of these studies are presented here. In tandem with the fouling-factor analyses, a study evaluated for each plant the potential causes of pressure loss. The combined results of the global fouling factor calculations and the pressure-loss evaluations demonstrated two key points: (1) that the available thermal margin against fouling, which can vary substantially from plant to plant, has an important bearing on whether a given plant exhibits losses in electrical generating capacity, and (2) that a wide variety of causes can result in SG thermal performance degradation

  8. High-performance nanostructured thermoelectric generators for micro combined heat and power systems

    International Nuclear Information System (INIS)

    Zhang, Yanliang; Wang, Xiaowei; Cleary, Martin; Schoensee, Luke; Kempf, Nicholas; Richardson, Joseph

    2016-01-01

    Highlights: • A TEG is fabricated using high-efficiency nanostructured thermoelectric materials. • The TEG produces high power density of 2.1 W/cm"2 with 5.3% electrical efficiency. • A micro-CHP system is demonstrated by integrating the TEG into a gas-fired boiler. - Graphical Abstract: - Abstract: Micro combined heat and power (micro-CHP) systems are promising pathways to increase power generation efficiencies. Here a new class of micro-CHP system without moving parts is experimentally demonstrated by integrating high-temperature thermoelectric generators (TEGs) and residential gas-fired boilers, thus enabling wide applications. The TEGs fabricated using high-efficiency nanostructured bulk half-Heusler alloys generate ultrahigh power density of 2.1 W/cm"2 with 5.3% electrical efficiency under 500 °C temperature differences between the hot and cold sides. The TEG system harnesses the untapped exergy between the combustion gas and water, and converts thermal energy into electric power with 4% heat-to-electricity efficiency based on the total heat input into the TEGs. The high-performance TEGs open lots of opportunities to transform power generation technologies and improve energy efficiency.

  9. Performance of PZC-Mo generator and labeling results prepared with its eluate and MDP kit

    International Nuclear Information System (INIS)

    Yishu Liu

    2006-01-01

    This paper described the performance of Tc-99m generator prepared with Mo adsorbent PZC and irradiated nature MoO 3 , and the labeling results of MDP kit prepared with Tc-99m eluted from PZC-Mo generator and MDP was report as well. ThreeTc-99m generators was prepared with different batches of PZC and reactor irradiated nature Mo. The adsorption efficiency of two batches of the PZC is good (96.4% and 93.4%) and that of one batch of PZC is not satisfy (77.8%). The elution efficiency is not so high, and it increases along with the elution date. The elution file is very broad till to 30 ml and the Mo breakthrough is high to unacceptable. The labelling efficiency of MDP kit, prepared with Tc-99m eluate eluted with saline containing 0.05% NaClO from Mo-PZC generator, is approximately 77∼84% and it can reach to >98% labelling with eluate without containing 0.05%HClO in eluate. (author)

  10. Environmental Performance of Electricity Generation Based on Resources: A Life Cycle Assessment Case Study in Turkey

    Directory of Open Access Journals (Sweden)

    Zerrin Günkaya

    2016-10-01

    Full Text Available The aim of this paper was to determine how to change the environmental performance of electricity generation depending on the resources and their shares, in order to support decision-makers. Additionally, this paper presents an application of life cycle assessment (LCA methodology to determine the environmental burdens of electricity generation in Turkey. Electricity generation data in Turkey for the years 2012 and 2023 were used as a case study. The functional unit for electricity generation was 1 kWh. The LCA calculations were carried out using CML-IA (v3.00 data and the results were interpreted with respect to Monte Carlo simulation analysis (with the Monte Carlo function built in SimaPro 8.0.1 software. The results demonstrated that the fossil fuel consumption not only contributes to global warming, but it also has effects on the elemental basis of abiotic depletion due to raw material consumption for plant infrastructure. Additionally, it was observed that the increasing proportion of wind power in the electricity mix would also increase certain life cycle impacts (such as the elemental basis of abiotic depletion, human ecotoxicity, and terrestrial ecotoxicity in Turkey’s geography compared to increasing the share of other renewable energy sources, such as hydropower, geothermal, as well as solar.

  11. Generation of oxy-hydrogen gas and its effect on performance of spark ignition engine

    Science.gov (United States)

    Patil, N. N.; Chavan, C. B.; More, A. S.; Baskar, P.

    2017-11-01

    Considering the current scenario of petroleum fuels, it has been observed that, they will last for few years from now. On the other hand, the ever increasing cost of a gasoline fuels and their related adverse effects on environment caught the attention of researchers to find a supplementary source. For commercial fuels, supplementary source is not about replacing the entire fuel, instead enhancing efficiency by simply making use of it in lesser amount. From the recent research that has been carried out, focus on the use of Hydrogen rich gas as a supplementary source of fuel has increased. But the problem related to the storage of hydrogen gas confines the application of pure hydrogen in petrol engine. Using oxy-hydrogen gas (HHO) generator the difficulties of storing the hydrogen have overcome up to a certain limit. The present study highlights on performance evaluation of conventional petrol engine by using HHO gas as a supplementary fuel. HHO gas was generated from the electrolysis of water. KOH solution of 3 Molar concentration was used which act as a catalyst and accelerates the rate of generation of HHO gas. Quantity of gas to be supplied to the engine was controlled by varying amount of current. It was observed that, engine performance was improved on the introduction of HHO gas.

  12. Performance comparison of LOE protection of synchronous generator in the presence of UPFC

    Directory of Open Access Journals (Sweden)

    Seyed Yaser Ebrahimi

    2016-03-01

    Full Text Available Generator loss of excitation (LOE protection is a principal protection of power system which operate based on impedance measurement. This relay calculates impedance by measuring voltage and current at the generator terminal. On the other hand, the presence of unified power flow controller (UPFC in transmission lines changes measured voltage and current signals during loss of excitation. In this paper, the impact of UPFC on the performance of LOE protection has been analytically investigated. Afterwards, using modeling results, it has been attained that the presence of UPFC leads to the drastic delay on the performance of LOE relay. This delay results to the overloading and damaging of armature winding of generator. It is also shown that in partial LOE presence of UPFC causes under-reach of the relay. Finally, the phasor measurement units (PMUs based method has been proposed to reduce the effect of UPFC on the LOE protection. The results indicate that using this new method, the delay of LOE relay has been reduced. In the surveys conducted, various conditions of the power system have been considered.

  13. Interactive Light Stimulus Generation with High Performance Real-Time Image Processing and Simple Scripting

    Directory of Open Access Journals (Sweden)

    László Szécsi

    2017-12-01

    Full Text Available Light stimulation with precise and complex spatial and temporal modulation is demanded by a series of research fields like visual neuroscience, optogenetics, ophthalmology, and visual psychophysics. We developed a user-friendly and flexible stimulus generating framework (GEARS GPU-based Eye And Retina Stimulation Software, which offers access to GPU computing power, and allows interactive modification of stimulus parameters during experiments. Furthermore, it has built-in support for driving external equipment, as well as for synchronization tasks, via USB ports. The use of GEARS does not require elaborate programming skills. The necessary scripting is visually aided by an intuitive interface, while the details of the underlying software and hardware components remain hidden. Internally, the software is a C++/Python hybrid using OpenGL graphics. Computations are performed on the GPU, and are defined in the GLSL shading language. However, all GPU settings, including the GPU shader programs, are automatically generated by GEARS. This is configured through a method encountered in game programming, which allows high flexibility: stimuli are straightforwardly composed using a broad library of basic components. Stimulus rendering is implemented solely in C++, therefore intermediary libraries for interfacing could be omitted. This enables the program to perform computationally demanding tasks like en-masse random number generation or real-time image processing by local and global operations.

  14. Application of ANN-SCE model on the evaluation of automatic generation control performance

    Energy Technology Data Exchange (ETDEWEB)

    Chang-Chien, L.R.; Lo, C.S.; Lee, K.S. [National Cheng Kung Univ., Tainan, Taiwan (China)

    2005-07-01

    An accurate evaluation of load frequency control (LFC) performance is needed to balance minute-to-minute electricity generation and demand. In this study, an artificial neural network-based system control error (ANN-SCE) model was used to assess the performance of automatic generation controls (AGC). The model was used to identify system dynamics for control references in supplementing AGC logic. The artificial neural network control error model was used to track a single area's LFC dynamics in Taiwan. The model was used to gauge the impacts of regulation control. Results of the training, evaluating, and projecting processes showed that the ANN-SCE model could be algebraically decomposed into components corresponding to different impact factors. The SCE information obtained from testing of various AGC gains provided data for the creation of a new control approach. The ANN-SCE model was used in conjunction with load forecasting and scheduled generation data to create an ANN-SCE identifier. The model successfully simulated SCE dynamics. 13 refs., 10 figs.

  15. Thermoelectric generator performance analysis: Influence of pin tapering on the first and second law efficiencies

    International Nuclear Information System (INIS)

    Yilbas, B.S.; Ali, H.

    2015-01-01

    Highlights: • Double tapering of thermoelectric elements improves first and second law efficiency. • Pin geometric feature maximizing device output work does not maximize thermal efficiency. • Pin geometric feature maximizing first law efficiency slight alters for maximum second law efficiency. • External resistance and operating temperature ratios influence design configuration of thermoelectric generator. - Abstract: Thermoelectric generators are the important candidates for clean energy conversion from the waste heat; however, their low efficiency limits the practical applications of the devices. Tailoring the geometric configuration of the device in line with the operating conditions can improve the device performance. Consequently; in the present study, the influence of the pin geometric configuration on the thermoelectric generator performance is investigated. The dimensionless tapering parameter is introduced and its effect on the first and second law efficiencies is examined for various operating conditions including the external load resistance and the temperature ratio. It is found that the first and second law efficiencies are significantly influenced by the pin geometry. The dimensionless tapering parameter (a), increasing tapering of the thermoelectric pins, within the range of 2 ⩽ a ⩽ 4 results in improved first and second law efficiencies. However, the dimensionless tapering parameter maximizing the first and second law efficiencies does not maximize the device output power. This behavior is associated with the external load resistance which has a considerable influence on the device output power such that increasing external load resistance lowers the device output power

  16. Lightning Protection Performance Assessment of Transmission Line Based on ATP model Automatic Generation

    Directory of Open Access Journals (Sweden)

    Luo Hanwu

    2016-01-01

    Full Text Available This paper presents a novel method to solve the initial lightning breakdown current by combing ATP and MATLAB simulation software effectively, with the aims to evaluate the lightning protection performance of transmission line. Firstly, the executable ATP simulation model is generated automatically according to the required information such as power source parameters, tower parameters, overhead line parameters, grounding resistance and lightning current parameters, etc. through an interface program coded by MATLAB. Then, the data are extracted from the generated LIS files which can be obtained by executing the ATP simulation model, the occurrence of transmission lie breakdown can be determined by the relative data in LIS file. The lightning current amplitude should be reduced when the breakdown occurs, and vice the verse. Thus the initial lightning breakdown current of a transmission line with given parameters can be determined accurately by continuously changing the lightning current amplitude, which is realized by a loop computing algorithm that is coded by MATLAB software. The method proposed in this paper can generate the ATP simulation program automatically, and facilitates the lightning protection performance assessment of transmission line.

  17. Interactive Light Stimulus Generation with High Performance Real-Time Image Processing and Simple Scripting.

    Science.gov (United States)

    Szécsi, László; Kacsó, Ágota; Zeck, Günther; Hantz, Péter

    2017-01-01

    Light stimulation with precise and complex spatial and temporal modulation is demanded by a series of research fields like visual neuroscience, optogenetics, ophthalmology, and visual psychophysics. We developed a user-friendly and flexible stimulus generating framework (GEARS GPU-based Eye And Retina Stimulation Software), which offers access to GPU computing power, and allows interactive modification of stimulus parameters during experiments. Furthermore, it has built-in support for driving external equipment, as well as for synchronization tasks, via USB ports. The use of GEARS does not require elaborate programming skills. The necessary scripting is visually aided by an intuitive interface, while the details of the underlying software and hardware components remain hidden. Internally, the software is a C++/Python hybrid using OpenGL graphics. Computations are performed on the GPU, and are defined in the GLSL shading language. However, all GPU settings, including the GPU shader programs, are automatically generated by GEARS. This is configured through a method encountered in game programming, which allows high flexibility: stimuli are straightforwardly composed using a broad library of basic components. Stimulus rendering is implemented solely in C++, therefore intermediary libraries for interfacing could be omitted. This enables the program to perform computationally demanding tasks like en-masse random number generation or real-time image processing by local and global operations.

  18. Evaluation of the performance of combined cooling, heating, and power systems with dual power generation units

    International Nuclear Information System (INIS)

    Knizley, Alta A.; Mago, Pedro J.; Smith, Amanda D.

    2014-01-01

    The benefits of using a combined cooling, heating, and power system with dual power generation units (D-CCHP) is examined in nine different U.S. locations. One power generation unit (PGU) is operated at base load while the other is operated following the electric load. The waste heat from both PGUs is used for heating and for cooling via an absorption chiller. The D-CCHP configuration is studied for a restaurant benchmark building, and its performance is quantified in terms of operational cost, primary energy consumption (PEC), and carbon dioxide emissions (CDE). Cost spark spread, PEC spark spread, and CDE spark spread are examined as performance indicators for the D-CCHP system. D-CCHP system performance correlates well with spark spreads, with higher spark spreads signifying greater savings through implementation of a D-CCHP system. A new parameter, thermal difference, is introduced to investigate the relative performance of a D-CCHP system compared to a dual PGU combined heat and power system (D-CHP). Thermal difference, together with spark spread, can explain the variation in savings of a D-CCHP system over a D-CHP system for each location. The effect of carbon credits on operational cost savings with respect to the reference case is shown for selected locations. - Highlights: • We investigate benefits from using combined cooling, heating, and power systems. • A dual power generation unit configuration is considered for CCHP and CHP. • Spark spreads for cost, energy, and emissions correlate with potential savings. • Thermal difference parameter helps to explain variations in potential savings. • Carbon credits may increase cost savings where emissions savings are possible

  19. Performance of Generating Plant: Managing the Changes. Part 4: Markets and Risk Management Strategy

    Energy Technology Data Exchange (ETDEWEB)

    Moss, Terry; Loedolff, Gerhard; Griffin, Rob; Kydd, Robert; Micali, Vince [Eskom (South Africa)

    2008-05-15

    The WEC Committee on the Performance of Generating Plant (PGP) has been collecting and analysing power plant performance statistics worldwide for more than 30 years and has produced regular reports, which include examples of advanced techniques and methods for improving power plant performance through benchmarking. A series of reports from the various working groups was issued in 2008. This reference presents the results of Working Group 4 (WG4). WG4 will monitor the development of power markets, in particular from the market risk management point of view, including operational risks. It will assess various risk management strategies used by market players around the world and develop recommendations for a wider deployment of successful strategies. The report covers the project approach and outcomes.

  20. Theoretical analysis of heat transfer in, and electrical performance of, a milliwatt radioisotopic powered thermoelectric generator

    International Nuclear Information System (INIS)

    Biver, C.J.

    1975-01-01

    A simplified, theoretical model has been made for a radioisotope-powered milliwatt thermoelectric generator (RTG). Calculations of unit heat transfer and electrical performance characteristics are made in two ways: (a) using discrete values of input physical parameters for an individual unit; and (b) using a statistical simulation (Monte Carlo) approach for estimating the variation in performance in a group of N-units. The statistical simulation approach is useful in: (a) estimating the allowable range of input parameters conducive to the production design meeting specifications in a group of N-units; and (b) determining particular parameters that must be significantly restricted in variation to achieve desired performance. The available experimental data, as compared with the discrete value calculations, are in quite good agreement (within 5 percent generally). (U.S.)

  1. The performance of a combined solar photovoltaic (PV) and thermoelectric generator (TEG) system

    DEFF Research Database (Denmark)

    Bjørk, Rasmus; Nielsen, Kaspar Kirstein

    2015-01-01

    The performance of a combined solar photovoltaic (PV) and thermoelectric generator (TEG) system is examined using an analytical model for four different types of commercial PVs and a commercial bismuth telluride TEG. The TEG is applied directly on the back of the PV, so that the two devices have...... the same temperature. The PVs considered are crystalline Si (c-Si), amorphous Si (a-Si), copper indium gallium (di) selenide (CIGS) and cadmium telluride (CdTe) cells. The degradation of PV performance with temperature is shown to dominate the increase in power produced by the TEG, due to the low...... efficiency of the TEG. For c-Si, CIGS and CdTe PV cells the combined system produces a lower power and has a lower efficiency than the PV alone, whereas for an a-Si cell the total system performance may be slightly increased by the TEG....

  2. Performance and optimum characteristics by finite element analysis of a coreless ironless electric generator for low wind density power generation

    Science.gov (United States)

    Razali, Akhtar; Rahman, Fadhlur; Leong, Yap Wee; Razali Hanipah, Mohd; Azri Hizami, Mohd

    2018-04-01

    Cogging is an attraction of magnetism between permanent magnets and soft ironcore lamination in a conventional electric ironcore generator. The presence of cog in the generator is seen somehow restricted the application of the generator in an application where low rotational torque is required. Cog torque requires an additional input power to overcome, hence became one of the power loss sources. With the increasing of power output, the cogging is also proportionally increased. This leads to the increasing of the supplied power of the driver motor to overcome the cog. Therefore, this research is embarked to study fundamentally about the possibility of removing ironcore lamination in an electric generator. This research deals with removal of ironcore lamination in electric generator to eliminate cog torque. A confinement technique is proposed to confine and focus magnetic flux by introducing opposing permanent magnets arrangement. There were several parameters analysed using the JMAG Designer. Transient response analysis was used in the JMAG Designer. The parameters analysed were the number of coil turns per phase, gap distance between the magnet pairs as well as the magnet grade used. These few parameters were analysed under the open circuit condition. Results showed with the increasing of gap distance, output voltage produced decreased. The increment of number of turns in the coils and higher magnet grades used, these increased the output voltage of the generator. With the help of these results, a reference point is established to get optimum design parameter for fabrication of working prototype.

  3. Assessing the performance and benefits of customer distributed generation developers under uncertainties

    International Nuclear Information System (INIS)

    Zangiabadi, Mansoureh; Feuillet, Rene; Lesani, Hamid; Hadj-Said, Nouredine; Kvaloy, Jan T.

    2011-01-01

    In this paper, the performance of customer-owned distributed generation (DG) units is quantified from different perspectives through an uncertainty study. A Monte Carlo-based method is applied to assess the stochastic operation of the customer-owned DG units in the power distribution system. Several cases are studied to analyze the impact on system performance of using such generators, with the emphasis on benefits. The results of the studied cases show that proper operation of customer-owned DG units placed close to significant consumption centers offers several benefits which lead to significant energy savings and improvement in the performance indices while maintaining the cost-effectiveness. Furthermore, based on the energy demand, different electricity price scenarios considering a cost sensitivity analysis are performed to indicate how the variations in electricity price influence each scenario's feasibility. It is concluded that implementation of a proper energy purchase policy, and allocating the benefits of DG units to the owners, improves the economic performance of their investments and encourages customer DG developers to connect DG to the distribution network. -- Research highlights: → Focusing on the main drives for customers and utilities to adopt DG solutions. → Assessing the stochastic operation of the customer-owned DG units in the power distribution system using Monte Carlo method. → Studying the technical and economic impacts of customer-owned DG units in a distribution system. → Implementing the proper power purchase policy by the utility to encourage DG owners to operate at peak load periods. → Performing different electricity price scenarios to indicate the ability of customer-owned DG units to reduce the volatility in prices.

  4. Investigation on the performance of polymer zirconium compound (PZC) for chromatographic Tc-99m generator preparation

    International Nuclear Information System (INIS)

    Le Van So

    2004-01-01

    The performance of PZC was investigated for chromatographic Tc-99m generator preparation. Mo-adsorption of PZC in different Mo-solutions and Tc-99m elution of 99 Mo-PZC column were studied. Mo- adsorption capacity of higher than 250mgMo/gPZC and Tc-99m elution yield of higher than 80% were achieved with PZC adsorbent. Mo-99 breakthrough of 0.02% and Molybdenum element breakthrough of around 5μg Mo/ml were found in Tc-99m eluate. A good relationship between the Mo-content of adsorption solution and the Mo-adsorption capacity, adsorption percentage, Mo-breakthrough and Tc-99m elution yield was found. The preparation of PZC based Tc-99m chromatographic generator with 4 gram weight of PZC was successfully conducted. (author)

  5. Proportional-Type Performance Recovery DC-Link Voltage Tracking Algorithm for Permanent Magnet Synchronous Generators

    Directory of Open Access Journals (Sweden)

    Seok-Kyoon Kim

    2017-09-01

    Full Text Available This study proposes a disturbance observer-based proportional-type DC-link voltage tracking algorithm for permanent magnet synchronous generators (PMSGs. The proposed technique feedbacks the only proportional term of the tracking errors, and it contains the nominal static and dynamic feed-forward compensators coming from the first-order disturbance observers. It is rigorously proved that the proposed method ensures the performance recovery and offset-free properties without the use of the integrators of the tracking errors. A wind power generation system has been simulated to verify the efficacy of the proposed method using the PSIM (PowerSIM software with the DLL (Dynamic Link Library block.

  6. Performance analysis of a co-generation system using solar energy and SOFC technology

    International Nuclear Information System (INIS)

    Akikur, R.K.; Saidur, R.; Ping, H.W.; Ullah, K.R.

    2014-01-01

    Highlights: • A new concept of a cogeneration system is proposed and investigated. • The system comprises solar collector, PV, SOFC and heat exchanger. • 83.6% Power and heat generation efficiency has been found at fuel cell mode. • 85.1% Efficiency of SOSE has been found at H2 production mode. • The heat to power ratio of SOFC mode has been found about 0.917. - Abstract: Due to the increasing future energy demands and global warming, the renewable alternative energy sources and the efficient power systems have been getting importance over the last few decades. Among the renewable energy technologies, the solar energy coupling with fuel cell technology will be the promising possibilities for the future green energy solutions. Fuel cell cogeneration is an auspicious technology that can potentially reduce the energy consumption and environmental impact associated with serving building electrical and thermal demands. In this study, performance assessment of a co-generation system is presented to deliver electrical and thermal energy using the solar energy and the reversible solid oxide fuel cell. A mathematical model of the co-generation system is developed. To illustrate the performance, the system is considered in three operation modes: a solar-solid oxide fuel cell (SOFC) mode, which is low solar radiation time when the solar photovoltaic (PV) and SOFC are used for electric and heat load supply; a solar-solid oxide steam electrolyzer (SOSE) mode, which is high solar radiation time when PV is used for power supply to the electrical load and to the steam electrolyzer to generate hydrogen (H 2 ); and a SOFC mode, which is the power and heat generation mode of reversible SOFC using the storage H 2 at night time. Also the effects of solar radiation on the system performances and the effects of temperature on RSOFC are analyzed. In this study, 100 kW electric loads are considered and analyzed for the power and heat generation in those three modes to evaluate

  7. Dynamic performance of power generation systems for off-shore oil and gas platforms

    DEFF Research Database (Denmark)

    Pierobon, Leonardo; Breuhaus, Peter; Haglind, Fredrik

    2014-01-01

    %) arises on the prediction of the rotational speed of the high pressure shaft, while the largest deviation (average relative error ~20%) occurs in the evaluation of the pressure at the outlet of the low pressure turbine. As waste heat recovery units (e.g. organic Rankine cycles) are likely...... to be implemented in future off-shore platforms, the proposed model may serve in the design phase for a preliminary assessment of the dynamic response of the power generation system and to evaluate if requirements such as minimum and maximum frequency during transient operation and the recovery time are satisfied......On off-shore oil and gas platforms two or more gas turbines typically support the electrical demand on site by operating as a stand-alone (island) power system. As reliability and availability are major concerns during operation, the dynamic performance of the power generation system becomes...

  8. Auger generation as an intrinsic limit to tunneling field-effect transistor performance

    International Nuclear Information System (INIS)

    Teherani, James T.; Agarwal, Sapan; Chern, Winston; Antoniadis, Dimitri A.; Solomon, Paul M.; Yablonovitch, Eli

    2016-01-01

    Many in the microelectronics field view tunneling field-effect transistors (TFETs) as society's best hope for achieving a >10× power reduction for electronic devices; however, despite a decade of considerable worldwide research, experimental TFET results have significantly underperformed simulations and conventional MOSFETs. To explain the discrepancy between TFET experiments and simulations, we investigate the parasitic leakage current due to Auger generation, an intrinsic mechanism that cannot be mitigated with improved material quality or better device processing. We expose the intrinsic link between the Auger and band-to-band tunneling rates, highlighting the difficulty of increasing one without the other. From this link, we show that Auger generation imposes a fundamental limit on ultimate TFET performance.

  9. Optical Fiber Demodulation System with High Performance for Assessing Fretting Damage of Steam Generator Tubes.

    Science.gov (United States)

    Huang, Peijian; Wang, Ning; Li, Junying; Zhu, Yong; Zhang, Jie; Xi, Zhide

    2018-01-12

    In order to access the fretting damage of the steam generator tube (SGT), a fast fiber Fabry-Perot (F-P) non-scanning correlation demodulation system based on a super luminescent light emitting diode (SLED) was performed. By demodulating the light signal coming out from the F-P force sensor, the radial collision force between the SGT and the tube support plate (TSP) was interrogated. For higher demodulation accuracy, the effects of the center wavelength, bandwidth, and spectrum noise of SLED were discussed in detail. Specially, a piezoelectric ceramic transducer (PZT) modulation method was developed to get rid of the interference of mode coupling induced by different types of fiber optics in the demodulation system. The reflectivity of optical wedge and F-P sensor was optimized. Finally, the demodulation system worked well in a 1:1 steam generator test loop and successfully demodulated a force signal of 32 N with a collision time of 2 ms.

  10. Auger generation as an intrinsic limit to tunneling field-effect transistor performance

    Energy Technology Data Exchange (ETDEWEB)

    Teherani, James T., E-mail: j.teherani@columbia.edu [Department of Electrical Engineering, Columbia University, New York, New York 10027 (United States); Agarwal, Sapan [Sandia National Laboratories, Albuquerque, New Mexico 87123 (United States); Chern, Winston; Antoniadis, Dimitri A. [Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); Solomon, Paul M. [IBM T.J. Watson Research Center, Yorktown Heights, New York 10598 (United States); Yablonovitch, Eli [Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, California 94720 (United States)

    2016-08-28

    Many in the microelectronics field view tunneling field-effect transistors (TFETs) as society's best hope for achieving a >10× power reduction for electronic devices; however, despite a decade of considerable worldwide research, experimental TFET results have significantly underperformed simulations and conventional MOSFETs. To explain the discrepancy between TFET experiments and simulations, we investigate the parasitic leakage current due to Auger generation, an intrinsic mechanism that cannot be mitigated with improved material quality or better device processing. We expose the intrinsic link between the Auger and band-to-band tunneling rates, highlighting the difficulty of increasing one without the other. From this link, we show that Auger generation imposes a fundamental limit on ultimate TFET performance.

  11. Development of microstructure to optimise mechanical performance of power generation equipment

    International Nuclear Information System (INIS)

    Marshall, P.

    1986-11-01

    The factors responsible for the development of microstructure in CEGB construction ceramics and steels is assessed as a function of composition, thermomechanical treatment, thermal ageing and environmental degradation. The relationships between microstructure and mechanical properties (tensile, toughness, creep and fatigue) of relevance to structures operating in power generation equipment is then developed in quantitative terms. The conclusions from the assessment are as follows: 1 The relationship between microstructure and mechanical properties of construction ceramics and steels used in the power generation industry has been assessed. 2 Factors which significantly influence microstructure and thus mechanical properties are chemical composition, thermomechanical treatment, ageing and environmental degradation. The influence of such microstructural changes in tensile, toughness, fatigue and creep properties of ceramics and steels is assessed. 3 The benefits arising from an understanding of materials behaviour are discussed in terms of improved materials and the assessment of plant performance. (author)

  12. 基于不确定时间区间TBN的洪水漫坝风险分析%Risk Analysis of Flood Overtopping Based on Uncertain Time Interval TBN

    Institute of Scientific and Technical Information of China (English)

    涂传飞; 王剑; 王红卫

    2013-01-01

    In the process of flood overtopping,the uncertainty of events' duration time caused by state uncertainty of natural conditions,dam and emergency measures,and the effect of emergency measures are both key factors that affect the flood overtopping risk.The traditional time interval was transformed into an uncertain time interval and an uncertain time interval Temporal Bayesian Network (TBN) was proposed.After that,a new inferring algorithm of the TBN was discussed.On the basis,flood overtopping risk analysis model,in which emergency measures were considered,was established.Finally,the simulation result shows that the model can accumulate information,judge the importance of each emergency measure,express the state uncertainty and time uncertainty which both exist in the process of flood overtopping and accordingly increase the accuracy of flood overtopping risk analysis.%洪水漫坝过程中,自然条件、坝体及应急处置等状态的不确定性所导致的事件持续时间的不确定性,以及应急处置措施的效果是影响漫坝风险的关键因素.首先将传统时间区间改造为不确定时间区间,提出了一种不确定时间区间时间贝叶斯网络(TBN),并推导了该TBN的推理算法.在此基础上构建了考虑应急处置措施的洪水漫坝风险分析模型.仿真结果表明该模型具有信息时间累积能力,能判断各应急处置措施的重要程度,表达了洪水漫坝过程中同时存在的状态不确定性和时间不确定性,提高了漫坝风险分析的精度.

  13. Investigation on the performance of a viscoelastic dielectric elastomer membrane generator.

    Science.gov (United States)

    Zhou, Jianyou; Jiang, Liying; Khayat, Roger E

    2015-04-21

    Dielectric elastomer generators (DEGs), as a recent transduction technology, harvest electrical energy by scavenging mechanical energy from diverse sources. Their performance is affected by various material properties and failure modes of the dielectric elastomers. This work presents a theoretical analysis on the performance of a dielectric elastomer membrane generator under equi-biaxial loading conditions. By comparing our simulation results with the experimental observations existing in the literature, this work considers the fatigue life of DE-based devices under cyclic loading for the first time. From the simulation results, it is concluded that the efficiency of the DEG can be improved by raising the deforming rate and the prescribed maximum stretch ratio, and applying an appropriate bias voltage. However, the fatigue life expectancy compromises the efficiency improvement of the DEG. With the consideration of the fatigue life, applying an appropriate bias voltage appears to be a more desirable way to improve the DEG performance. The general framework developed in this work is expected to provide an increased understanding on the energy harvesting mechanisms of the DEGs and benefit their optimal design.

  14. Effect of first and second generation biodiesel blends on engine performance and emission

    Energy Technology Data Exchange (ETDEWEB)

    Azad, A. K., E-mail: azad.cqu@gmail.com, E-mail: a.k.azad@cqu.edu.au; Rasul, M. G., E-mail: m.rasul@cqu.edu.au; Bhuiya, M. M. K., E-mail: m.bhuiya@cqu.edu.au [School of Engineering and Technology, Central Queensland University, Rockhampton, QLD 4702 (Australia); Islam, Rubayat, E-mail: rubayat12@yahoo.com [Department of Mechanical Engineering, Bangladesh University of Engineering and Technology, Dhaka-1000 (Bangladesh)

    2016-07-12

    The biodiesel is a potential source of alternative fuel which can be used at different proportions with diesel fuel. This study experimentally investigated the effect of blend percentage on diesel engine performance and emission using first generation (soybean) and second generation (waste cooking) biodiesel. The characterization of the biodiesel was done according to ASTM and EN standards and compared with ultralow sulfur diesel (ULSD) fuel. A multi-cylinder test bed engine coupled with electromagnetic dynamometer and 5 gas analyzer were used for engine performance and emission test. The investigation was made using B5, B10 and B15 blends for both biodiesels. The study found that brake power (BP) and brake torque (BT) slightly decreases and brake specific fuel consumption (BSFC) slightly increases with an increase in biodiesel blends ratio. Besides, a significant reduction in exhaust emissions (except NO{sub x} emission) was found for both biodiesels compared to ULSD. Soybean biodiesel showed better engine performance and emissions reduction compared with waste cooking biodiesel. However, NO{sub x} emission for B5 waste cooking biodiesel was lower than soybean biodiesel.

  15. Durango: Scalable Synthetic Workload Generation for Extreme-Scale Application Performance Modeling and Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Carothers, Christopher D. [Rensselaer Polytechnic Institute (RPI); Meredith, Jeremy S. [ORNL; Blanco, Marc [Rensselaer Polytechnic Institute (RPI); Vetter, Jeffrey S. [ORNL; Mubarak, Misbah [Argonne National Laboratory; LaPre, Justin [Rensselaer Polytechnic Institute (RPI); Moore, Shirley V. [ORNL

    2017-05-01

    Performance modeling of extreme-scale applications on accurate representations of potential architectures is critical for designing next generation supercomputing systems because it is impractical to construct prototype systems at scale with new network hardware in order to explore designs and policies. However, these simulations often rely on static application traces that can be difficult to work with because of their size and lack of flexibility to extend or scale up without rerunning the original application. To address this problem, we have created a new technique for generating scalable, flexible workloads from real applications, we have implemented a prototype, called Durango, that combines a proven analytical performance modeling language, Aspen, with the massively parallel HPC network modeling capabilities of the CODES framework.Our models are compact, parameterized and representative of real applications with computation events. They are not resource intensive to create and are portable across simulator environments. We demonstrate the utility of Durango by simulating the LULESH application in the CODES simulation environment on several topologies and show that Durango is practical to use for simulation without loss of fidelity, as quantified by simulation metrics. During our validation of Durango's generated communication model of LULESH, we found that the original LULESH miniapp code had a latent bug where the MPI_Waitall operation was used incorrectly. This finding underscores the potential need for a tool such as Durango, beyond its benefits for flexible workload generation and modeling.Additionally, we demonstrate the efficacy of Durango's direct integration approach, which links Aspen into CODES as part of the running network simulation model. Here, Aspen generates the application-level computation timing events, which in turn drive the start of a network communication phase. Results show that Durango's performance scales well when

  16. Computational investigations of the mixing performance inside liquid slugs generated by a microfluidic T-junction.

    Science.gov (United States)

    Li, Yuehao; Reddy, Rupesh K; Kumar, Challa S S R; Nandakumar, Krishnaswamy

    2014-09-01

    Droplet-based microfluidics has gained extensive research interest as it overcomes several challenges confronted by conventional single-phase microfluidics. The mixing performance inside droplets/slugs is critical in many applications such as advanced material syntheses and in situ kinetic measurements. In order to understand the effects of operating conditions on the mixing performance inside liquid slugs generated by a microfluidic T-junction, we have adopted the volume of fluid method coupled with the species transport model to study and quantify the mixing efficiencies inside slugs. Our simulation results demonstrate that an efficient mixing process is achieved by the intimate collaboration of the twirling effect and the recirculating flow. Only if the reagents are distributed transversely by the twirling effect, the recirculating flow can bring in convection mechanism thus facilitating mixing. By comparing the mixing performance inside slugs at various operating conditions, we find that slug size plays the key role in influencing the mixing performance as it determines the amount of fluid to be distributed by the twirling effect. For the cases where short slugs are generated, the mixing process is governed by the fast convection mechanism because the twirling effect can distribute the fluid to the flow path of the recirculating flow effectively. For cases with long slugs, the mixing process is dominated by the slow diffusion mechanism since the twirling effect is insufficient to distribute the large amount of fluid. In addition, our results show that increasing the operating velocity has limited effects on improving the mixing performance. This study provides the insight of the mixing process and may benefit the design and operations of droplet-based microfluidics.

  17. Steam generator tube performance. Experience with water-cooled nuclear power reactors during 1985

    International Nuclear Information System (INIS)

    Tatone, O.S.; Tapping, R.L.

    1988-12-01

    The performance of steam generator tubes at water-cooled reactors during 1985 has been reviewed. Seventy-three of 168 reactors in the survey experienced tube degradation sufficient for the tubes to be plugged. The number of tubes plugged was 6837 or 0.28% of those in service. The leading cause of tube failure was stress corrosion cracking from the primary side. Stress corrosion cracking or intergranular attack from the secondary side and pitting were also major causes of tube failure. Unlike most previous years, fretting was a substantial problem at some reactors. Overall, corrosion continued to account for more than 80% of the defects. 20 refs

  18. Steam generator tube performance: experience with water-cooled nuclear power reactors during 1978

    International Nuclear Information System (INIS)

    Tatone, O.S.; Pathania, R.S.

    1980-02-01

    The performance of steam generator tubes in water-cooled nuclear power reactors has been reviewed for 1978. Tube failures occurred at 31 of the 86 reactors surveyed. Causes of these failures and procedures designed to deal with them are described. A dramatic decrease in the number of tubes plugged was evident in 1978 compared to the previous year. This is attributed to diligent application of techniques developed from in-plant experience and research and development programs over the past several years. (auth)

  19. The F-16 Onboard Oxygen Generating System: Performance Evaluation and Man Rating

    Science.gov (United States)

    1983-08-01

    OXYGEN GENERATING , YSTEM: PERFORMANCE EVALUATION AND MAN RATING Thomas C. Horch , Captain, USAF Richard L. Miller, Ph.D. John B. Bomar, Jr...C. Horch , Capt, USAF; R. L. Miller, 8. CONTRACT OR GRANT NUMBER(i) Ph.D.; J. B. Bomar, Jr., Lt Col, IJSAF, BSC; J. B. Tedor, Maj, USAF, BSC; R. D...limitation (as of 1983); however, the information may no longer need protection since it is 14 years. At the time of its publication, Capt Thomas Horch

  20. High-Performance Constant Power Generation in Grid-Connected PV Systems

    DEFF Research Database (Denmark)

    Sangwongwanich, Ariya; Yang, Yongheng; Blaabjerg, Frede

    2016-01-01

    An advanced power control strategy by limiting the maximum feed-in power of PV systems has been proposed, which can ensure a fast and smooth transition between maximum power point tracking and Constant Power Generation (CPG). Regardless of the solar irradiance levels, high-performance and stable...... operation are always achieved by the proposed control strategy. It can regulate the PV output power according to any set-point, and force the PV systems to operate at the left side of the maximum power point without stability problems. Experimental results have verified the effectiveness of the proposed CPG...

  1. Asymmetric actuating structure generates negligible influence on the supporting base for high performance scanning probe microscopies

    Science.gov (United States)

    Yi Yan, Gang; Bin Liu, Yong; Hua Feng, Zhi

    2014-02-01

    An asymmetric actuating structure generating negligible influence on the supporting base for high performance scanning probe microscopies is proposed in this paper. The actuator structure consists of two piezostacks, one is used for actuating while the other is for counterbalancing. In contrast with balanced structure, the two piezostacks are installed at the same side of the supporting base. The effectiveness of the structure is proved by some experiments with the actuators fixed to the free end of a cantilever. Experimental results show that almost all of the vibration modes of the cantilever are suppressed effectively at a wide frequency range of 90 Hz-10 kHz.

  2. Performance analysis of a solar-powered solid state heat engine for electricity generation

    International Nuclear Information System (INIS)

    Long, Rui; Li, Baode; Liu, Zhichun; Liu, Wei

    2015-01-01

    A hybrid system consisting of a CPC (compound parabolic collector) system, a SOE (solid oxide electrolyzer) system and a PEMFC (proton exchange membrane fuel cell) system was proposed to harvest solar energy. And a sensitivity analysis was conducted to evaluate the system performance. The impacts of operating temperatures of the SOE and PEMFC system, and the direct irradiation intensity of the sun on the performance characteristics were systematically analyzed. Results revealed that there exists an optimal SOE operating temperature leading to the maximum power output and maximum electrical efficiency simultaneously. Larger operating temperature of the PEMFC resulted in larger power output and higher efficiency. There also existed optimal direct irradiation intensities leading to the maximum power output and maximum electrical efficiency. Furthermore, the performance of the proposed solar energy harvesting system for practical use in real-life was also simulated. This may serve a clean technology for electricity generation. - Highlights: • A hybrid system consisting of CPC, SOE and PEMFC is proposed to harvest solar energy. • A sensitivity analysis was conducted to evaluate the system performance. • Power output and electrical efficiency have maximum values. • Performance of the proposed hybrid system for practical use was simulated.

  3. A global fouling factor methodology for analyzing steam generator thermal performance degradation

    International Nuclear Information System (INIS)

    Kreider, M.A.; White, G.A.; Varrin, R.D.

    1998-01-01

    Over the past few years, steam generator (SG) thermal performance degradation has led to decreased plant efficiency and power output at numerous PWR nuclear power plants with recirculating-type SGs. The authors have developed and implemented methodologies for quantitatively evaluating the various sources of SG performance degradation, both internal and external to the SG pressure boundary. These methodologies include computation of the global fouling factor history, evaluation of secondary deposit thermal resistance using deposit characterization data, and consideration of pressure loss causes unrelated to the tube bundle, such as hot-leg temperature streaming and SG moisture separator performance. In order to evaluate the utility of the global fouling factor methodology, the authors performed case studies for a number of PWR SG designs. Key results from two of these studies are presented here. Uncertainty analyses were performed to determine whether the calculated fouling factor for each plant represented significant fouling or whether uncertainty in key variables (e.g., steam pressure or feedwater flow rate) could be responsible for calculated fouling. The methodology was validated using two methods: by predicting the SG pressure following chemical cleaning at San Onofre 2 and also by performing a sensitivity study with the industry-standard thermal-hydraulics code ATHOS to investigate the effects of spatially varying tube scale distributions. This study indicated that the average scale thickness has a greater impact on fouling than the spatial distribution, showing that the assumption of uniform resistance inherent to the global fouling factor is reasonable. In tandem with the fouling-factor analyses, a study evaluated for each plant the potential causes of pressure loss. The combined results of the global fouling factor calculations and the pressure loss evaluations demonstrated two key points: 1) that the available thermal margin against fouling, which can

  4. Flux gain for a next-generation neutron reflectometer resulting from improved supermirror performance

    CERN Document Server

    Rehm, C

    2002-01-01

    Next-generation spallation neutron source facilities will offer instruments with unprecedented capabilities through simultaneous enhancement of source power and usage of advanced optical components. The Spallation Neutron Source (SNS), already under construction at Oak Ridge National Laboratory and scheduled to be completed by 2006, will provide greater than an order of magnitude more effective source flux than current state-of-the-art facilities, including the most advanced research reactors. An additional order of magnitude gain is expected through the use of new optical devices and instrumentation concepts. Many instrument designs require supermirror neutron guides with very high critical angles for total reflection. In this contribution, we will discuss how the performance of a modern neutron-scattering instrument depends on the efficiency of these supermirrors. We summarize current limitations of supermirror coatings and outline ideas for enhancing their performance, particularly for improving the reflec...

  5. Dynamic performance of maximum power point tracking circuits using sinusoidal extremum seeking control for photovoltaic generation

    Science.gov (United States)

    Leyva, R.; Artillan, P.; Cabal, C.; Estibals, B.; Alonso, C.

    2011-04-01

    The article studies the dynamic performance of a family of maximum power point tracking circuits used for photovoltaic generation. It revisits the sinusoidal extremum seeking control (ESC) technique which can be considered as a particular subgroup of the Perturb and Observe algorithms. The sinusoidal ESC technique consists of adding a small sinusoidal disturbance to the input and processing the perturbed output to drive the operating point at its maximum. The output processing involves a synchronous multiplication and a filtering stage. The filter instance determines the dynamic performance of the MPPT based on sinusoidal ESC principle. The approach uses the well-known root-locus method to give insight about damping degree and settlement time of maximum-seeking waveforms. This article shows the transient waveforms in three different filter instances to illustrate the approach. Finally, an experimental prototype corroborates the dynamic analysis.

  6. Performance of an improved first generation optical CT scanner for 3D dosimetry

    International Nuclear Information System (INIS)

    Qian, Xin; Wuu, Cheng-Shie; Adamovics, John

    2013-01-01

    Performance analysis of a modified 3D dosimetry optical scanner based on the first generation optical CT scanner OCTOPUS is presented. The system consists of PRESAGE™ dosimeters, the modified 3D scanner, and a new developed in-house user control panel written in Labview program which provides more flexibility to optimize mechanical control and data acquisition technique. The total scanning time has been significantly reduced from initial 8 h to ∼2 h by using the modified scanner. The functional performance of the modified scanner has been evaluated in terms of the mechanical integrity uncertainty of the data acquisition process. Optical density distribution comparison between the modified scanner, OCTOPUS and the treatment plan system has been studied. It has been demonstrated that the agreement between the modified scanner and treatment plans is comparable with that between the OCTOPUS and treatment plans. (note)

  7. An Inclusive Investigation on Conceivable Performance of Rice Straw Incinerated Electricity Generation

    Science.gov (United States)

    Bhattacharjee, Subhadeep; Mohanta, Subhajit

    2018-03-01

    Biomass energy is one of the potential renewable energy sources which occupy 77% of the available natural resources of the world. In India, agro residues constitute a major part of the total annual production of the biomass resource. Rice is the major crop in India that leaves substantial quantity of straw in the field. 34% of rice straw residue produced in the country is surplus and is either left in the field as uncollected or to a large extent open-field burnt. Thus, the unutilized rice straw is found promising for heat and power generation either through incineration (direct combustion) or thermo chemical conversion. This present work envisages the comprehensive performative evaluation of a rice straw supported biomass incineration power plant mainly through plant performance characterization, plant economics, and co-firing issues with emission analysis.

  8. Improved thermal source term generation capability for use in performance assessment and system studies

    International Nuclear Information System (INIS)

    King, J.; Rhodes, C.

    1994-01-01

    This paper describes work performed by the Civilian Radioactive Waste Management System (CRWMS) Management and Operating (M ampersand O) Contractor to improve spent nuclear fuel (SNF) waste stream characterization for system studies. It discusses how these new capabilities may be exploited for thermal source term generation for use in repository performance assessment modeling. SNF historical discharges have been exhaustively tracked, and significant effort has gone into capturing, verifying, and electronically managing spent fuel inventory data. Future discharge projections are produced annually by the Energy Information Administration (EIA) using sophisticated computer models. The output of these models is coupled with annually updated SNF historical discharges to produce what is referred to as the open-quotes reactor database.close quotes This database and related data are published in a variety of ways including on magnetic media for consistent use by analysts or other interested parties

  9. Performance testing of PZC generators for 99mTc production

    International Nuclear Information System (INIS)

    Bulos, Adelina DM.

    2006-01-01

    The report briefly describes the performance testing done on seven batches of polyzirconium column (PZC) material. PZC is a ready-to-use high molybdenum-capacity column material for adsorbing reactor-produced 99 Mo. The PZC material was manufactured by Kaken Co in Japan and was sent to PNRI for performance evaluation. Fission molybdenum was eluted from a commercial 99 Mo - 99m Tc generator. The eluted 99 Mo in a molybdenum carrier solution was adsorbed on PZC through a series of procedures. The mixture was decanted to a 90 x 12 mm glass column. 99m Tc was eluted with saline solution. The parameters measured were Tc 99m yield, %molybdenum adsorption and desorption, elution profile and radiochemical purity. (author)

  10. Performance of automatic generation control mechanisms with large-scale wind power

    Energy Technology Data Exchange (ETDEWEB)

    Ummels, B.C.; Gibescu, M.; Paap, G.C. [Delft Univ. of Technology (Netherlands); Kling, W.L. [Transmission Operations Department of TenneT bv (Netherlands)

    2007-11-15

    The unpredictability and variability of wind power increasingly challenges real-time balancing of supply and demand in electric power systems. In liberalised markets, balancing is a responsibility jointly held by the TSO (real-time power balancing) and PRPs (energy programs). In this paper, a procedure is developed for the simulation of power system balancing and the assessment of AGC performance in the presence of large-scale wind power, using the Dutch control zone as a case study. The simulation results show that the performance of existing AGC-mechanisms is adequate for keeping ACE within acceptable bounds. At higher wind power penetrations, however, the capabilities of the generation mix are increasingly challenged and additional reserves are required at the same level. (au)

  11. Examination of the Properties of a Spent Fuel based Electricity Generation System - Scintillator Performance Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Haneol; Yim, Man-Sung [KAIST, Daejeon (Korea, Republic of)

    2016-05-15

    Gammavoltaic was proposed by Karl Scharf in 1960. The low efficiency resulted in gammavoltaic being used as a radiation detector. In the 1990s the efficiency of gammavoltaic increased by the use of a scintillator. Gammavoltaic was further studied as a power source for spent fuel transportation and a nuclear battery in the 2000s Haneol Lee and Man-Sung Yim also suggested electricity generation system based on spent fuel stored inside the fuel pool of a nuclear power plant. This study proposed the systematic design of an electricity conversion system using CsI(Tl) scintillator and a-Si photovoltaic cell. As such, this study is selected to be a reference paper. The results of this paper indicate a self-absorption effect from the reference model. This effect is negligible while the irradiation degradation has to be considered. Two main ways to reduce radiation induced degradation are scintillator shielding and replacing scintillator material with a material having higher radiation resistance. The analysis of the scintillator used in the 'electricity generation system using gamma radiation from spent fuel' was performed to evaluate the ideal electricity generation in the reference research.

  12. Refrigeration Performance and Entropy Generation Analysis for Reciprocating Magnetic Refrigerator with Gd Plates

    Directory of Open Access Journals (Sweden)

    Yonghua You

    2018-06-01

    Full Text Available In the current work, a novel 2D numerical model of stationary grids was developed for reciprocating magnetic refrigerators, with Gd plates, in which the magneto-caloric properties, derived from the Weiss molecular field theory, were adopted for the built-in energy source of the magneto-caloric effect. The numerical simulation was conducted under the conditions of different structural and operational parameters, and the effects of the relative fluid displacement (φ on the specific refrigeration capacity (qref and the Coefficient of Performance (COP were obtained. Besides the variations of entropy, the generation rate and number were studied and the contours of the local entropy generation rate are presented for discussion. From the current work, it is found that with an increase in φ, both the qref and COP followed the convex variation trend, while the entropy generation number (Ns varied concavely. As for the current cases, the maximal qref and COP were equal to 151.2 kW/m3 and 9.11, respectively, while the lowest Ns was the value of 2.4 × 10−4 K−1. However, the optimal φ for the largest qref and COP, and for the lowest Ns, were inconsistent, thus, some compromises need be made in the optimization of magnetic refrigerators.

  13. Power performance of the general-purpose heat source radioisotope thermoelectric generator

    International Nuclear Information System (INIS)

    Bennett, G.L.; Lombardo, J.J.; Rock, B.J.

    1986-01-01

    The General-Purpose Heat Source Radioisotope Thermoelectric Generator (GRHS-RTG) has been developed under the sponsorship of the Department of Energy (DOE) to provide electrical power for the National Aeronautics and Space Administration (NASA) Galileo mission to Jupiter and the joint NASA/European Space Agency (ESA) Ulysses mission to study the polar regions of the sun. A total of five nuclear-heated generators and one electrically heated generator have been built and tested, proving out the design concept and meeting the specification requirements. The GPHS-RTG design is built upon the successful-technology used in the RTGs flown on the two NASA Voyager spacecraft and two US Air Force communications satellites. THe GPHS-RTG converts about 4400 W(t) from the nuclear heat source into at least 285 W(e) at beginning of mission (BOM). The GPHS-RTG consists of two major components: the General-Purpose Heat Source (GPHS) and the Converter. A conceptual drawing of the GPHs-RTG is presented and its design and performance are described

  14. Study on development system of increasing gearbox for high-performance wind-power generator

    Science.gov (United States)

    Xu, Hongbin; Yan, Kejun; Zhao, Junyu

    2005-12-01

    Based on the analysis of the development potentiality of wind-power generator and domestic manufacture of its key parts in China, an independent development system of the Increasing Gearbox for High-performance Wind-power Generator (IGHPWG) was introduced. The main elements of the system were studied, including the procedure design, design analysis system, manufacturing technology and detecting system, and the relative important technologies were analyzed such as mixed optimal joint transmission structure of the first planetary drive with two grade parallel axle drive based on equal strength, tooth root round cutting technology before milling hard tooth surface, high-precise tooth grinding technology, heat treatment optimal technology and complex surface technique, and rig test and detection technique of IGHPWG. The development conception was advanced the data share and quality assurance system through all the elements of the development system. The increasing Gearboxes for 600KW and 1MW Wind-power Generator have been successfully developed through the application of the development system.

  15. High performance electrode for electrochemical oxygen generator cell based on solid electrolyte ion transport membrane

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Wei; Shao, Zongping; Ran, Ran; Chen, Zhihao; Zeng, Pingying; Gu, Hongxia; Jin, Wanqin; Xu, Nanping [College of Chemistry and Chemical Engineering, Nanjing University of Technology, No. 5 Xin Mofan Road, Nanjing 210009, JiangSu (China)

    2007-06-30

    A double-layer composite electrode based on Ba{sub 0.5}Sr{sub 0.5}Co{sub 0.8}Fe{sub 0.2}O{sub 3-{delta}} + Sm{sub 0.2}Ce{sub 0.8}O{sub 1.9} (BSCF + SDC) and BSCF + SDC + Ag was investigated to be a promising cathode and also anode for the electrochemical oxygen generator based on samaria doped ceria electrolyte. The Ag particles in the second layer were not only the current collector but also the improver for the oxygen adsorption at the electrode. a.c. impedance results indicated that the electrode polarization resistance, as low as 0.0058 {omega} cm{sup 2} was reached at 800 C under air. In oxygen generator cell performance test, the electrode resistance dropped to half of the value at zero current density under an applied current density of 2.34 A cm{sup -2} at 700 C, and on the same conditions the oxygen generator cell was continual working for more than 900 min with a Faradic efficiency of {proportional_to}100%. (author)

  16. Feasibility and performance evaluation of generating and recording visual evoked potentials using ambulatory Bluetooth based system.

    Science.gov (United States)

    Ellingson, Roger M; Oken, Barry

    2010-01-01

    Report contains the design overview and key performance measurements demonstrating the feasibility of generating and recording ambulatory visual stimulus evoked potentials using the previously reported custom Complementary and Alternative Medicine physiologic data collection and monitoring system, CAMAS. The methods used to generate visual stimuli on a PDA device and the design of an optical coupling device to convert the display to an electrical waveform which is recorded by the CAMAS base unit are presented. The optical sensor signal, synchronized to the visual stimulus emulates the brain's synchronized EEG signal input to CAMAS normally reviewed for the evoked potential response. Most importantly, the PDA also sends a marker message over the wireless Bluetooth connection to the CAMAS base unit synchronized to the visual stimulus which is the critical averaging reference component to obtain VEP results. Results show the variance in the latency of the wireless marker messaging link is consistent enough to support the generation and recording of visual evoked potentials. The averaged sensor waveforms at multiple CPU speeds are presented and demonstrate suitability of the Bluetooth interface for portable ambulatory visual evoked potential implementation on our CAMAS platform.

  17. The PZC-based Tc-99m generator preparation and its performance test

    International Nuclear Information System (INIS)

    Liu Yishu

    2007-01-01

    This paper described the preparation of Tc-99m generator prepared with Japan distributing Mo adsorbent PZC and irradiated nature MoO 3 and its performance test. Four Tc-99m generators were prepared with different batches of PZC and reactor irradiated nature MoO 3 . The adsorption capacity of PZC to Mo is approximately 200mgMo/gPZC. The adsorption efficiency of three batches PZC is good (>90%) and that of one batch of PZC is not good enough (∼83%). The loss of fine powder (The PZC is fragile) is quite different with the different preparation process of PZC. The elution efficiency is 80-90% and has the up trend with the elution date. The Mo breakthrough can be controlled to acceptable level by connecting HZO safe column containing 1.0g HZO. All the specifications of eluted from PZC-based Tc-99m generator can meet the requirements under Sodium Pertechnetate injection in China Pharmacopoeia. (author)

  18. Examination of the Properties of a Spent Fuel based Electricity Generation System - Scintillator Performance Analysis

    International Nuclear Information System (INIS)

    Lee, Haneol; Yim, Man-Sung

    2016-01-01

    Gammavoltaic was proposed by Karl Scharf in 1960. The low efficiency resulted in gammavoltaic being used as a radiation detector. In the 1990s the efficiency of gammavoltaic increased by the use of a scintillator. Gammavoltaic was further studied as a power source for spent fuel transportation and a nuclear battery in the 2000s Haneol Lee and Man-Sung Yim also suggested electricity generation system based on spent fuel stored inside the fuel pool of a nuclear power plant. This study proposed the systematic design of an electricity conversion system using CsI(Tl) scintillator and a-Si photovoltaic cell. As such, this study is selected to be a reference paper. The results of this paper indicate a self-absorption effect from the reference model. This effect is negligible while the irradiation degradation has to be considered. Two main ways to reduce radiation induced degradation are scintillator shielding and replacing scintillator material with a material having higher radiation resistance. The analysis of the scintillator used in the 'electricity generation system using gamma radiation from spent fuel' was performed to evaluate the ideal electricity generation in the reference research

  19. High-performance flat-panel solar thermoelectric generators with high thermal concentration

    Science.gov (United States)

    Kraemer, Daniel; Poudel, Bed; Feng, Hsien-Ping; Caylor, J. Christopher; Yu, Bo; Yan, Xiao; Ma, Yi; Wang, Xiaowei; Wang, Dezhi; Muto, Andrew; McEnaney, Kenneth; Chiesa, Matteo; Ren, Zhifeng; Chen, Gang

    2011-07-01

    The conversion of sunlight into electricity has been dominated by photovoltaic and solar thermal power generation. Photovoltaic cells are deployed widely, mostly as flat panels, whereas solar thermal electricity generation relying on optical concentrators and mechanical heat engines is only seen in large-scale power plants. Here we demonstrate a promising flat-panel solar thermal to electric power conversion technology based on the Seebeck effect and high thermal concentration, thus enabling wider applications. The developed solar thermoelectric generators (STEGs) achieved a peak efficiency of 4.6% under AM1.5G (1 kW m-2) conditions. The efficiency is 7-8 times higher than the previously reported best value for a flat-panel STEG, and is enabled by the use of high-performance nanostructured thermoelectric materials and spectrally-selective solar absorbers in an innovative design that exploits high thermal concentration in an evacuated environment. Our work opens up a promising new approach which has the potential to achieve cost-effective conversion of solar energy into electricity.

  20. High-performance flat-panel solar thermoelectric generators with high thermal concentration.

    Science.gov (United States)

    Kraemer, Daniel; Poudel, Bed; Feng, Hsien-Ping; Caylor, J Christopher; Yu, Bo; Yan, Xiao; Ma, Yi; Wang, Xiaowei; Wang, Dezhi; Muto, Andrew; McEnaney, Kenneth; Chiesa, Matteo; Ren, Zhifeng; Chen, Gang

    2011-05-01

    The conversion of sunlight into electricity has been dominated by photovoltaic and solar thermal power generation. Photovoltaic cells are deployed widely, mostly as flat panels, whereas solar thermal electricity generation relying on optical concentrators and mechanical heat engines is only seen in large-scale power plants. Here we demonstrate a promising flat-panel solar thermal to electric power conversion technology based on the Seebeck effect and high thermal concentration, thus enabling wider applications. The developed solar thermoelectric generators (STEGs) achieved a peak efficiency of 4.6% under AM1.5G (1 kW m(-2)) conditions. The efficiency is 7-8 times higher than the previously reported best value for a flat-panel STEG, and is enabled by the use of high-performance nanostructured thermoelectric materials and spectrally-selective solar absorbers in an innovative design that exploits high thermal concentration in an evacuated environment. Our work opens up a promising new approach which has the potential to achieve cost-effective conversion of solar energy into electricity. © 2011 Macmillan Publishers Limited. All rights reserved

  1. The performance of a Solar Aided Power Generation plant with diverse “configuration-operation” combinations

    International Nuclear Information System (INIS)

    Qin, Jiyun; Hu, Eric; Nathan, Graham J.

    2016-01-01

    Highlights: • Four configurations of solar preheaters have been proposed. • Three typical operation strategies of solar preheaters have been identified. • 12 “configuration-operation” combinations has been proposed. • There are superior combinations to achieve the highest solar thermal performance. - Abstract: Solar Aided Power Generation is an efficient way to integrate solar thermal energy into a fossil fuel fired power plant for solar power generation purposes. In this particular power plant, the solar heat is used to displace the extraction steam to preheat the feedwater to the boiler. The heat exchanger, which facilitates the heat exchange between the solar heat carried by the heat transfer fluid and the feedwater, is termed a solar preheater. Four possible configurations of the solar preheater, namely Parallel 1, Parallel 2, Series 1 and Series 2, are proposed in this paper. In this type of plant, the extraction steam flow rates must be adjusted according to the solar input. The ways to control the extraction steam flow rates are termed solar preheater operation strategies. Three typical strategies: the Constant Temperature control, Variable Temperature control with high to low temperature feedwater heater displacement and Variable Temperature control with low to high temperature feedwater heater displacement have been identified. Each configuration can be operated with one of the three strategies, resulting in twelve “configuration-operation” combinations/scenarios (shown in Table 1). Previous assessments and modelling of such a plant have only been based on a single combination. In this paper, a Solar Aided Power Generation plant, modified from a typical 300 MW power plant, is used to understand the plant’s performance for all twelve of the available combinations. The results show that the instantaneous and annual technical performances of such a plant are dependent on the combinations used. The scenario 10 (Table 1) is superior to the

  2. Numerical investigation on the performance of fin and tube heat exchangers using rectangular vortex generators

    Science.gov (United States)

    Zeeshan, Mohd; Hazarika, Saheera Azmi; Nath, Sujit; Bhanja, Dipankar

    2017-07-01

    In the present work, a 3-D numerical investigation has been performed to explore the effect of attack angles on the thermal-hydraulic performance of fin and tube heat exchanger (FTHE) using rectangular winglet pairs (RWPs). RWPs are placed adjacent to the tubes and three attack angels are considered for the study i.e. 5°, 15° and 25°. The effect of attack angles are examined on the heat transfer characteristics as well as in pressure drop penalty with airside Reynolds number Rea ranges from 500 to 900. Two performance evaluation criteria namely PEC1 i.e. area goodness factor (j/f) and PEC2 i.e. heat transfer rate per unit fan power consumption (Q/Pf) are considered for the performance evaluation. Furthermore, MOORA method is applied to obtain the performance order of FTHE configurations by taking PEC1 and PEC2 as beneficial attributes and fan power Pf as a non-beneficial attribute, keeping equal importance to each attribute. The results show that 5° attack angle provides the better performance in terms of PEC1 as heat transfer coefficient is increased by 27.70% at Rea=500 and 32.73% at Rea=900 respectively with 13.01% increased pressure drop penalty at Rea=500 and 14.26% at Rea=900 respectively. In terms of PEC2, though the 5° attack angle provides the high values of Q/Pf factor among the 15° and 25° attack angles, but it is found insignificant to replace the baseline configuration i.e. plain fin and tube heat exchanger configuration without vortex generators. Moreover, in MOORA optimization analysis also, it is found that 5° attack angle provides the better thermal-hydraulic performance.

  3. Explore the performance limit of a solar PV – thermochemical power generation system

    International Nuclear Information System (INIS)

    Li, Wenjia; Hao, Yong

    2017-01-01

    Highlights: •Theoretical net solar-to-electric efficiency of 51.5% is attainable. •Design of efficient PVT systems is governed by at least 5 key considerations. •Concentration ratio has the most pronounced influence on PVT system efficiency. •Efficient PV, low emissivity and high concentration deliver the best performance. -- Abstract: Performance limit of a solar hybrid power generation system integrating efficient photovoltaic (PV) cells and methanol thermal (T) decomposition is explored from a thermodynamic perspective within the capability of state-of-the-art technologies. This type of PVT system features potentially high “net solar-to-electric efficiency” in general, primarily resulting from a key difference in the design of the thermal part compared with conventional PVT systems, i.e. replacing heat engines by a thermochemical power generation module for thermal energy utilization. Key design parameters of the system, including PV cell type, emissivity, solar concentration ratio and solar concentrator type, are individually studied. A system combining all such optimized aspects is projected to achieve net solar-to-electric efficiencies up to 51.5%, after taking all major (e.g. optical, radiative) losses into consideration. This study reveals important insights and enriches understanding on design principles of efficient PVT systems aimed at comprehensive and effective utilization of solar energy.

  4. Next Generation Anodes for Lithium Ion Batteries: Thermodynamic Understanding and Abuse Performance.

    Energy Technology Data Exchange (ETDEWEB)

    Fenton, Kyle R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Allcorn, Eric [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Nagasubramanian, Ganesan [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2018-01-01

    As we develop new materials to increase performance of lithium ion batteries for electric vehicles, the impact of potential safety and reliability issues become increasingly important. In addition to electrochemical performance increases (capacity, energy, cycle life, etc.), there are a variety of materials advancements that can be made to improve lithium-ion battery safety. Issues including energetic thermal runaway, electrolyte decomposition and flammability, anode SEI stability, and cell-level abuse tolerance behavior. Introduction of a next generation materials, such as silicon based anode, requires a full understanding of the abuse response and degradation mechanisms for these anodes. This work aims to understand the breakdown of these materials during abuse conditions in order to develop an inherently safe power source for our next generation electric vehicles. The effect of materials level changes (electrolytes, additives, silicon particle size, silicon loading, etc.) to cell level abuse response and runaway reactions will be determined using several techniques. Experimentation will start with base material evaluations in coin cells and overall runaway energy will be evaluated using techniques such as differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), and accelerating rate calorimetry (ARC). The goal is to understand the effect of materials parameters on the runaway reactions, which can then be correlated to the response seen on larger cells (18650). Experiments conducted showed that there was significant response from these electrodes. Efforts to minimize risk during testing were taken by development of a smaller capacity cylindrical design in order to quantify materials decision and how they manifest during abuse response.

  5. Performance of droplet generator and droplet collector in liquid droplet radiator under microgravity

    Science.gov (United States)

    Totani, T.; Itami, M.; Nagata, H.; Kudo, I.; Iwasaki, A.; Hosokawa, S.

    2002-06-01

    The Liquid Droplet Radiator (LDR) has an advantage over comparable conventional radiators in terms of the rejected heat power-weight ratio. Therefore, the LDR has attracted attention as an advanced radiator for high-power space systems that will be prerequisite for large space structures. The performance of the LDR under microgravity condition has been studied from the viewpoint of operational space use of the LDR in the future. In this study, the performances of a droplet generator and a droplet collector in the LDR are investigated using drop shafts in Japan: MGLAB and JAMIC. As a result, it is considered that (1) the droplet generator can produce uniform droplet streams in the droplet diameter range from 200 to 280 [µm] and the spacing range from 400 to 950 [µm] under microgravity condition, (2) the droplet collector with the incidence angle of 35 degrees can prevent a uniform droplet stream, in which droplet diameter is 250 [µm] and the velocity is 16 [m/s], from splashing under microgravity condition, whereas splashes may occur at the surface of the droplet collector in the event that a nonuniform droplet stream collides against it.

  6. Performance analysis of a complete adiabatic logic system driven by the proposed power clock generator

    International Nuclear Information System (INIS)

    Kanungo, Jitendra; Dasgupta, S.

    2014-01-01

    We analyze the energy performance of a complete adiabatic circuit/system including the Power Clock Generator (PCG) at the 90 nm CMOS technology node. The energy performance in terms of the conversion efficiency of the PCG is extensively carried out under the variations of supply voltage, process corner and the driver transistor's width. We propose an energy-efficient singe cycle control circuit based on the two-stage comparator for the synchronous charge recovery sinusoidal power clock generator (PCG). The proposed PCG is used to drive the 4-bit adiabatic Ripple Carry Adder (RCA) and their simulation results are compared with the adiabatic RCA driven by the reported PCG. We have also simulated the logically equivalent static CMOS RCA circuit to compare the energy saving of adiabatic and non-adiabatic logic circuits. In the clock frequency range from 25 MHz to 1GHz, the proposed PCG gives a maximum conversion efficiency of 56.48%. This research work shows how the design of an efficient PCG increases the energy saving of adiabatic logic. (semiconductor integrated circuits)

  7. GeneNetWeaver: in silico benchmark generation and performance profiling of network inference methods.

    Science.gov (United States)

    Schaffter, Thomas; Marbach, Daniel; Floreano, Dario

    2011-08-15

    Over the last decade, numerous methods have been developed for inference of regulatory networks from gene expression data. However, accurate and systematic evaluation of these methods is hampered by the difficulty of constructing adequate benchmarks and the lack of tools for a differentiated analysis of network predictions on such benchmarks. Here, we describe a novel and comprehensive method for in silico benchmark generation and performance profiling of network inference methods available to the community as an open-source software called GeneNetWeaver (GNW). In addition to the generation of detailed dynamical models of gene regulatory networks to be used as benchmarks, GNW provides a network motif analysis that reveals systematic prediction errors, thereby indicating potential ways of improving inference methods. The accuracy of network inference methods is evaluated using standard metrics such as precision-recall and receiver operating characteristic curves. We show how GNW can be used to assess the performance and identify the strengths and weaknesses of six inference methods. Furthermore, we used GNW to provide the international Dialogue for Reverse Engineering Assessments and Methods (DREAM) competition with three network inference challenges (DREAM3, DREAM4 and DREAM5). GNW is available at http://gnw.sourceforge.net along with its Java source code, user manual and supporting data. Supplementary data are available at Bioinformatics online. dario.floreano@epfl.ch.

  8. Power generation and heating performances of integrated system of ammonia–water Kalina–Rankine cycle

    International Nuclear Information System (INIS)

    Zhang, Zhi; Guo, Zhanwei; Chen, Yaping; Wu, Jiafeng; Hua, Junye

    2015-01-01

    Highlights: • Integrated system of ammonia–water Kalina–Rankine cycle (AWKRC) is investigated. • Ammonia–water Rankine cycle is operated for cogenerating room heating-water in winter. • Kalina cycle with higher efficiency is operated for power generation in other seasons. • Power recovery efficiency accounts thermal efficiency and waste heat absorbing ratio. • Heating water with 70 °C and capacity of 55% total reclaimed heat load is cogenerated. - Abstract: An integrated system of ammonia–water Kalina–Rankine cycle (AWKRC) for power generation and heating is introduced. The Kalina cycle has large temperature difference during evaporation and small one during condensation therefore with high thermal efficiency for power generation, while the ammonia–water Rankine cycle has large temperature difference during condensation as well as evaporation, thus it can be adopted to generate heating-water as a by-product in winter. The integrated system is based on the Kalina cycle and converted to the Rankine cycle with a set of valves. The performances of the AWKRC system in different seasons with corresponding cycle loops were studied and analyzed. When the temperatures of waste heat and cooling water are 300 °C and 25 °C respectively, the thermal efficiency and power recovery efficiency of Kalina cycle are 20.9% and 17.4% respectively in the non-heating seasons, while these efficiencies of the ammonia–water Rankine cycle are 17.1% and 13.1% respectively with additional 55.3% heating recovery ratio or with comprehensive efficiency 23.7% higher than that of the Kalina cycle in heating season

  9. Investigation of thermodynamic performances for two solar-biomass hybrid combined cycle power generation systems

    International Nuclear Information System (INIS)

    Liu, Qibin; Bai, Zhang; Wang, Xiaohe; Lei, Jing; Jin, Hongguang

    2016-01-01

    Highlights: • Two solar-biomass hybrid combined cycle power generation systems are proposed. • The characters of the two proposed systems are compared. • The on-design and off-design properties of the system are numerically investigated. • The favorable performances of thermochemical hybrid routine are validated. - Abstract: Two solar-biomass hybrid combined cycle power generation systems are proposed in this work. The first system employs the thermochemical hybrid routine, in which the biomass gasification is driven by the concentrated solar energy, and the gasified syngas as a solar fuel is utilized in a combined cycle for generating power. The second system adopts the thermal integration concept, and the solar energy is directly used to heat the compressed air in the topping Brayton cycle. The thermodynamic performances of the developed systems are investigated under the on-design and off-design conditions. The advantages of the hybrid utilization technical mode are demonstrated. The solar energy can be converted and stored into the chemical fuel by the solar-biomass gasification, with the net solar-to-fuel efficiency of 61.23% and the net solar share of 19.01% under the specific gasification temperature of 1150 K. Meanwhile, the proposed system with the solar thermochemical routine shows more favorable behaviors, the annual system overall energy efficiency and the solar-to-electric efficiency reach to 29.36% and 18.49%, while the with thermal integration concept of 28.03% and 15.13%, respectively. The comparison work introduces a promising approach for the efficient utilization of the abundant solar and biomass resources in the western China, and realizes the mitigation of CO_2 emission.

  10. Performance analysis of a simple shunt and series compensated six-phase self-excited induction generator for stand-alone renewable energy generation

    International Nuclear Information System (INIS)

    Singh, G.K.; Kumar, A. Senthil; Saini, R.P.

    2011-01-01

    This paper describes a new generalized and efficient model for performance analysis of a six-phase self-excited induction generator (SPSEIG) with three capacitor excitation topologies; simple shunt, short shunt and long shunt. Mathematical model of SPSEIG is formulated using nodal admittance method based on graph theory. Attention is focused on the influence of the different capacitor connections on the generator overload and output power capabilities. The generator voltage with simple shunt excitation connection collapses when it is overloaded while with either the short shunt or long shunt excitation connection; generator is able to sustain the load at a lower operating voltage and larger load current. The matrix equation developed by nodal admittance method is solved by Genetic Algorithm (GA) technique to predetermine the steady-state performance of SPSEIG. The experimental and theoretical results are found to be in good agreement.

  11. Performance improvement in a tubular heat exchanger by punched delta-winglet vortex generators

    Science.gov (United States)

    Khanoknaiyakarn, C.; Promvonge, P.; Thianpong, C.; Skullong, S.

    2018-01-01

    A novel tubular heat exchanger incorporated with punched delta-winglet vortex generators (called perforated delta-winglet vortex generator, P-DWVG) is proposed for improving its thermal performance and energy saving. The P-DWVG elements are punched out from a straight tape having its width nearly equal to the tube diameter before insertion. The main aim at employing the P-DWVG insert is to produce counter-rotating vortices along the tube to promote turbulence intensity inside as well as to transport the cold fluid at the central core to the near-wall regions. The experiment was performed to study thermal behaviors in a uniform heat-fluxed tube inserted with P-DWVGs. The P-DWVGs with the attack angle of 45° were mounted periodically with three different blockage ratios (BR = 0.1, 0.2 and 0.3) and two pitch ratios (PR = 2 and 3). Air as the test fluid was varied to obtain turbulent airflow for Reynolds number (Re) in a range of 4,150-25,500. The experimental results show that the P-DWVG provides a considerable increase in the rate of heat transfer around 3.1-4.01 times whereas friction factor increases around 11.44- 34.23 times higher than the plain tube. To assess the real benefits of P-DWVGs, thermal performance factor (TEF) is examined and in the range of 1.39-1.48 where its maximum is at BR = 0.1 and PR = 2.

  12. Effects of voltage unbalance and system harmonics on the performance of doubly fed induction wind generators

    Science.gov (United States)

    Kiani, Morgan Mozhgan

    Inherent difficulties in management of electric power in the presence of an increasing demand for more energy, non-conventional loads such as digital appliances, and non-sustainable imported fossil fuels has initiated a multi-folded effort by many countries to restructure the way electric energy is generated, dispatched, and consumed. Smart power grid is the manifestation of many technologies that would eventually transforms the existing power grid into a more flexible, fault resilient, and intelligent system. Integration of distributed renewable energy sources plays a central role in successful implementation of this transformation. Among the renewable options, wind energy harvesting offers superior engineering and economical incentives with minimal environmental impacts. Doubly fed induction generators (DFIG) have turned into a serious contender for wind energy generators due to their flexibility in control of active and reactive power with minimal silicon loss. Significant presence of voltage unbalance and system harmonics in finite inertia transmission lines can potentially undermine the reliability of these wind generators. The present dissertation has investigated the impacts of system unbalances and harmonics on the performance of the DFIG. Our investigation indicates that these effects can result in an undesirable undulation in the rotor shaft which can potentially invoke mechanical resonance, thereby causing catastrophic damages to the installations and the power grid. In order to remedy the above issue, a control solution for real time monitoring of the system unbalance and optimal excitation of the three phase rotor currents in a DFIG is offered. The optimal rotor currents will create appropriate components of the magneto-motive force in the airgap that will actively compensate the undesirable magnetic field originated by the stator windings. Due to the iterative nature of the optimization procedure, field reconstruction method has been incorporated

  13. Development of a high performance eigensolver on the peta-scale next generation supercomputer system

    International Nuclear Information System (INIS)

    Imamura, Toshiyuki; Yamada, Susumu; Machida, Masahiko

    2010-01-01

    For the present supercomputer systems, a multicore and multisocket processors are necessary to build a system, and choice of interconnection is essential. In addition, for effective development of a new code, high performance, scalable, and reliable numerical software is one of the key items. ScaLAPACK and PETSc are well-known software on distributed memory parallel computer systems. It is needless to say that highly tuned software towards new architecture like many-core processors must be chosen for real computation. In this study, we present a high-performance and high-scalable eigenvalue solver towards the next-generation supercomputer system, so called 'K-computer' system. We have developed two versions, the standard version (eigen s) and enhanced performance version (eigen sx), which are developed on the T2K cluster system housed at University of Tokyo. Eigen s employs the conventional algorithms; Householder tridiagonalization, divide and conquer (DC) algorithm, and Householder back-transformation. They are carefully implemented with blocking technique and flexible two-dimensional data-distribution to reduce the overhead of memory traffic and data transfer, respectively. Eigen s performs excellently on the T2K system with 4096 cores (theoretical peak is 37.6 TFLOPS), and it shows fine performance 3.0 TFLOPS with a two hundred thousand dimensional matrix. The enhanced version, eigen sx, uses more advanced algorithms; the narrow-band reduction algorithm, DC for band matrices, and the block Householder back-transformation with WY-representation. Even though this version is still on a test stage, it shows 4.7 TFLOPS with the same dimensional matrix on eigen s. (author)

  14. Flux Gain for Next-Generation Neutron-Scattering Instruments Resulting From Improved Supermirror Performance

    International Nuclear Information System (INIS)

    Rehm, C.

    2001-01-01

    Next-generation spallation neutron source facilities will offer instruments with unprecedented capabilities through simultaneous enhancement of source power and usage of advanced optical components. The Spallation Neutron Source (SNS), already under construction at Oak Ridge National Laboratory and scheduled to be completed by 2006, will provide greater than an order of magnitude more effective source flux than current state-of-the-art facilities, including the most advanced research reactors. An additional order of magnitude gain is expected through the use of new optical devices and instrumentation concepts. Many instrument designs require supermirror (SM) neutron guides with very high critical angles for total reflection. In this contribution, they discuss how the performance of modern neutron scattering instruments depends on the efficiency of these supermirrors. They outline ideas for enhancing the performance of the SM coatings, particularly for improving the reflectivity at the position of the critical wave vector transfer. A simulation program has been developed which allows different approaches for SM designs to be studied. Possible instrument performance gains are calculated for the example of the SNS reflectometer

  15. Noisy EEG signals classification based on entropy metrics. Performance assessment using first and second generation statistics.

    Science.gov (United States)

    Cuesta-Frau, David; Miró-Martínez, Pau; Jordán Núñez, Jorge; Oltra-Crespo, Sandra; Molina Picó, Antonio

    2017-08-01

    This paper evaluates the performance of first generation entropy metrics, featured by the well known and widely used Approximate Entropy (ApEn) and Sample Entropy (SampEn) metrics, and what can be considered an evolution from these, Fuzzy Entropy (FuzzyEn), in the Electroencephalogram (EEG) signal classification context. The study uses the commonest artifacts found in real EEGs, such as white noise, and muscular, cardiac, and ocular artifacts. Using two different sets of publicly available EEG records, and a realistic range of amplitudes for interfering artifacts, this work optimises and assesses the robustness of these metrics against artifacts in class segmentation terms probability. The results show that the qualitative behaviour of the two datasets is similar, with SampEn and FuzzyEn performing the best, and the noise and muscular artifacts are the most confounding factors. On the contrary, there is a wide variability as regards initialization parameters. The poor performance achieved by ApEn suggests that this metric should not be used in these contexts. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Parallel Application Performance on Two Generations of Intel Xeon HPC Platforms

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Christopher H.; Long, Hai; Sides, Scott; Vaidhynathan, Deepthi; Jones, Wesley

    2015-10-15

    Two next-generation node configurations hosting the Haswell microarchitecture were tested with a suite of microbenchmarks and application examples, and compared with a current Ivy Bridge production node on NREL" tm s Peregrine high-performance computing cluster. A primary conclusion from this study is that the additional cores are of little value to individual task performance--limitations to application parallelism, or resource contention among concurrently running but independent tasks, limits effective utilization of these added cores. Hyperthreading generally impacts throughput negatively, but can improve performance in the absence of detailed attention to runtime workflow configuration. The observations offer some guidance to procurement of future HPC systems at NREL. First, raw core count must be balanced with available resources, particularly memory bandwidth. Balance-of-system will determine value more than processor capability alone. Second, hyperthreading continues to be largely irrelevant to the workloads that are commonly seen, and were tested here, at NREL. Finally, perhaps the most impactful enhancement to productivity might occur through enabling multiple concurrent jobs per node. Given the right type and size of workload, more may be achieved by doing many slow things at once, than fast things in order.

  17. Performance of a direct drive hydro turbine for wave power generation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Y-H; Kim, C-G [Division of Mechanical and Information Engineering, Korea Maritime University Dongsam-dong 1, Youngdo-ku, Busan, 606-791 (Korea, Republic of); Choi, Y-D; Kim, I-S [Department of Mechanical Engineering, Mokpo National University Muan-ro 560, Chunggye-myun, Jeonnam, 534-729 (Korea, Republic of); Hwang, Y-C, E-mail: lyh@hhu.ac.k [R and D Institute, Shinhan Precision Co. Ltd. Gomo-ri 313, Jinle-myun, Kimhae, 621-881 (Korea, Republic of)

    2010-08-15

    Clean and renewable energy technologies using ocean energy give us non-polluting alternatives to fossil-fueled power plants as a countermeasure against the global warming and growing demand for electrical energy. Among the ocean energy resources, wave power takes a growing interest because of its enormous amount of potential energy in the world. Therefore, various types of wave power system to capture the energy of ocean waves have been developed. However, suitable turbine type is not normalized yet because of relatively low efficiency of the turbine systems. The purpose of this study is to investigate the performance of a newly developed direct drive hydro turbine (DDT), which will be built in a caisson for wave power plant. Experiment and CFD analysis are conducted to clarify the turbine performance and internal flow characteristics. The results show that the DDT obtains fairly good turbine efficiency in both cases of with wave and no wave conditions. As the turbine performance is influenced considerably by the wave condition, designed point of the turbine should be determined according to the wave condition at an expected installation site. Most of the output power generates at the runner passage of the Stage 2.

  18. Generation Z’s Sustainable Volunteering: Motivations, Attitudes and Job Performance

    Directory of Open Access Journals (Sweden)

    Meehee Cho

    2018-05-01

    Full Text Available Generation Z (Gen Z, the future of America’s workforce, is forecasted to represent more than 30 million persons by 2020. Volunteer rates have been declining since 2002. Most compelling is that overall lowest volunteer rates were found to be within the Gen Z segment, with expectations of continued decline. Thus, this study explored motivations associated with sustainable volunteering by Gen Z based upon past research that documented intent to volunteer is strongly associated with age. In doing so, the Volunteer Functions Inventory was adopted to identify Gen Z motivations for volunteering. This study then employed the theory of planned behavior to test the relationships between Gen Z volunteering motivations, their attitudes and job performance using data obtained from 306 Gen Z volunteer special event participants. Among five motives identified to be important to Gen Z, only four motives (“value”, “career”, “learning” and “self-esteem” were found to significantly influence their attitudes. The ‘social’ motive was found to have no significant effect on their attitudes towards volunteering. This research framework was supported by validating the significant relationships between volunteer motivations, attitudes and job performance specific to the Gen Z volunteer segment. “Job training appropriateness” was found to be an important moderator for improving the relationships between Gen Z volunteer attitudes and job performance.

  19. The SSG Wave Energy Converter: Performance, Status and Recent Developments

    DEFF Research Database (Denmark)

    Vicinanza, Diego; Margheritini, Lucia; Kofoed, Jens Peter

    2012-01-01

    through turbines for electricity production. The system utilizes a wide spectrum of different wave conditions by means of multiple reservoirs, located at different levels above the still water level. Thereby, it obtains a high overall efficiency and it can be suitable for shoreline and breakwater...... applications, presenting particular advantages such as: sharing structure costs, availability of grid connection and infrastructures, recirculation of water inside the harbor, as the outlet of the turbines is on the rear part of the system. Recently, plans for the SSG pilot installation were in progress...... on wave loadings and on hydraulic performances (overtopping and reflection) in order to optimize the structure design. This paper addresses the influence of various parameters (geometry, wave characteristics) on overtopping, reflection and wave loading and it draws conclusions on performances...

  20. Design features in Korean next generation reactor focused on performance and economic viability

    International Nuclear Information System (INIS)

    Lee, J.S.; Chung, M.S.; Na, J.H.; Kim, M.C.; Choi, Y.S.

    2001-01-01

    As of the end of Dec. 1999, Korea's total nuclear power capacity reached 13,716 MWe with 16 units in operation and 4 units under construction. In addition, as part of the national long-term R and D programme launched in 1992, the Korean Next Generation Reactor (KNGR) is being developed to meet the electricity demands in the years to come and is expected to be safer and more economically competitive than any other conventional electric power sources in Korea. The KNGR project has successfully completed its second phase and is now on the third phase. In Phase III of the KNGR design development project, KNGR aims at reinforcing the economic competitiveness while maintaining safety goals. To achieve these objectives, the design options studied and the design requirements set up in the first phase are pursued while the second phase are being reviewed. This paper summarizes such efforts for design improvement in terms of performance and economic viability along with the status of nuclear power generation in Korea, focusing on KNGR currently. (author)

  1. Design, demonstration and performance of a versatile electrospray aerosol generator for nanomaterial research and applications

    International Nuclear Information System (INIS)

    Jennerjohn, Nancy; Fung, David C; Hirakawa, Karen S; Hinds, William; Kennedy, Nola J; Eiguren-Fernandez, Arantzazu; Prikhodko, Sergey; Zavala-Mendez, Jose D

    2010-01-01

    Carbon nanotubes are difficult to aerosolize in a controlled manner. We present a method for generating aerosols not only of carbon nanotubes, but also of many reference and proprietary materials including quantum dots, diesel particulate matter, urban dust, and their mixtures, using electrospraying. This method can be used as a teaching tool, or as the starting point for advanced research, or to deliver nanomaterials in animal exposure studies. This electrospray system generates 180 μg of nanotubes per m 3 of carrier gas, and thus aerosolizes an occupationally relevant mass concentration of nanotubes. The efficiency achievable for single-walled carbon nanotubes is 9.4%. This system is simple and quick to construct using ordinary lab techniques and affordable materials. Since it is easy to replace soiled parts with clean ones, experiments on different types of nanomaterial can be performed back to back without contamination from previous experiments. In this paper, the design, fabrication, operation and characterization of our versatile electrospray method are presented. Also, the morphological changes that carbon nanotubes undergo as they make the transition from dry powders to aerosol particles are presented.

  2. High-Temperature Performance of Stacked Silicon Nanowires for Thermoelectric Power Generation

    Science.gov (United States)

    Stranz, Andrej; Waag, Andreas; Peiner, Erwin

    2013-07-01

    Deep reactive-ion etching at cryogenic temperatures (cryo-DRIE) has been used to produce arrays of silicon nanowires (NWs) for thermoelectric (TE) power generation devices. Using cryo-DRIE, we were able to fabricate NWs of large aspect ratios (up to 32) using a photoresist mask. Roughening of the NW sidewalls occurred, which has been recognized as beneficial for low thermal conductivity. Generated NWs, which were 7 μm in length and 220 nm to 270 nm in diameter, were robust enough to be stacked with a bulk silicon chip as a common top contact to the NWs. Mechanical support of the NW array, which can be created by filling the free space between the NWs using silicon oxide or polyimide, was not required. The Seebeck voltage, measured across multiple stacks of up to 16 bulk silicon dies, revealed negligible thermal interface resistance. With stacked silicon NWs, we observed Seebeck voltages that were an order of magnitude higher than those observed for bulk silicon. Degradation of the TE performance of silicon NWs was not observed for temperatures up to 470°C and temperature gradients up to 170 K.

  3. 99Mo-99mTc generator - study of their performance and quality

    International Nuclear Information System (INIS)

    Acar, M.E.D.

    1987-01-01

    In this work the performance of the 99 Mo - 99m Tc generators produced at IPEN-CNEN/SP as well as the quality of the eluted solutions were analysed. The following parameters were studied: elution efficiency, chemical radiochemical, radionuclidic and microbiological purities and pH of the eluates. The 99m Tc yield ranged from 84,7 to 98,5%. The radioactivity due to the pertechnetate ion in the studied solutions was higher than 97,5%. The aluminium content in eluates, determined by spectrophotometry, was lower than 2,5 μg/ml and the pH of the solutions between 4,5 and 5,1. Radioactive impurities of the order of 10 -3 KBq 99 Mc/MBq 99m Tc and 10 -5 KBq 131 I/MBq 99m Tc were found in the eluates at the time of elution. Other γ emitting radioactive impurities were order of 10 -3 KBq/MBq 99m Tc. The eluates were sterile and pyrogen-free. From the results obtained in this work one can state that the IPEN-TEC generator is a reliable source of good quality 99m Tc-pertechnetate. (author) [pt

  4. Optical Fiber Demodulation System with High Performance for Assessing Fretting Damage of Steam Generator Tubes

    Directory of Open Access Journals (Sweden)

    Peijian Huang

    2018-01-01

    Full Text Available In order to access the fretting damage of the steam generator tube (SGT, a fast fiber Fabry-Perot (F-P non-scanning correlation demodulation system based on a super luminescent light emitting diode (SLED was performed. By demodulating the light signal coming out from the F-P force sensor, the radial collision force between the SGT and the tube support plate (TSP was interrogated. For higher demodulation accuracy, the effects of the center wavelength, bandwidth, and spectrum noise of SLED were discussed in detail. Specially, a piezoelectric ceramic transducer (PZT modulation method was developed to get rid of the interference of mode coupling induced by different types of fiber optics in the demodulation system. The reflectivity of optical wedge and F-P sensor was optimized. Finally, the demodulation system worked well in a 1:1 steam generator test loop and successfully demodulated a force signal of 32 N with a collision time of 2 ms.

  5. Effect of Cooling Units on the Performance of an Automotive Exhaust-Based Thermoelectric Generator

    Science.gov (United States)

    Su, C. Q.; Zhu, D. C.; Deng, Y. D.; Wang, Y. P.; Liu, X.

    2017-05-01

    Currently, automotive exhaust-based thermoelectric generators (AETEGs) are a hot topic in energy recovery. In order to investigate the influence of coolant flow rate, coolant flow direction and cooling unit arrangement in the AETEG, a thermoelectric generator (TEG) model and a related test bench are constructed. Water cooling is adopted in this study. Due to the non-uniformity of the surface temperature of the heat source, the coolant flow direction would affect the output performance of the TEG. Changing the volumetric flow rate of coolant can increase the output power of multi-modules connected in series or/and parallel as it can improve the temperature uniformity of the cooling unit. Since the temperature uniformity of the cooling unit has a strong influence on the output power, two cooling units are connected in series or parallel to research the effect of cooling unit arrangements on the maximum output power of the TEG. Experimental and theoretical analyses reveal that the net output power is generally higher with cooling units connected in parallel than cooling units connected in series in the cooling system with two cooling units.

  6. HIV avidity index performance using a modified fourth-generation immunoassay to detect recent HIV infections.

    Science.gov (United States)

    Suligoi, Barbara; Regine, Vincenza; Raimondo, Mariangela; Rodella, Anna; Terlenghi, Luigina; Caruso, Arnaldo; Bagnarelli, Patrizia; Capobianchi, Maria Rosaria; Zanchetta, Nadia; Ghisetti, Valeria; Galli, Claudio

    2017-10-26

    Detecting recent HIV infections is important to evaluate incidence and monitor epidemic trends. We aimed to evaluate the diagnostic performance and accuracy of the avidity index (AI) for discriminating for recent HIV infections. We collected serum samples from HIV-1 positive individuals: A) with known date of infection (midpoint in time between last HIV-negative and first HIV-positive test); B) infected for >1 year. Samples were divided into two aliquots: one diluted with phosphate buffered saline (PBS) and the other with 1 M guanidine. Both aliquots were assayed by the Architect HIV Ag/Ab Combo 4th generation assay (Abbott). We compared AI found in recent (RI=HIV subtype had no impact on AI misclassifications. All individuals in group A reached the AI threshold of 0.80 within 24 months after seroconversion. The AI is an accurate serological marker for discriminating recent from established HIV infections and meets WHO requirements for HIV incidence assays.

  7. Generation of synthetic influent data for performing (micro) pollutant wastewater treatment modelling studies

    DEFF Research Database (Denmark)

    Snip, L. J. P.; Aymerich, I.; Flores-Alsina, X.

    2015-01-01

    The use of Activated Sludge Models (ASM) (Henze et al., 2000) is constantly growing and both industry and academia are increasingly applying these tools when performing wastewater treatment plant (WWTP) engineering studies. Besides describing the behaviour of traditional pollutants such as organic...... carbon (C), nitrogen(N) and phosphorus(P), ASM models have been successfully upgraded to predict the fate of different types of micro-pollutants (Benedetti et al., 2013). Indeed, the potential adverse effects of micro-pollutants in aquatic environments have been an object of intensive research during...... (Gernaey et al., 2011). This is an important point since realistic data representing the influent wastewater dynamics are crucial to accomplish any WWTP modelling project (Rieger et al., 2012). For this reason, model-based influent generators/synthetic data are an alternative that has recently gained...

  8. Measurement of performance parameters of plasma source for plasma opening switch on Qiangguang-Ⅰ generator

    International Nuclear Information System (INIS)

    Luo Weixi; Zeng Zhengzhong; Lei Tianshi; Wang Liangping; Hu Yixiang; Sun Tieping; Huang Tao

    2012-01-01

    The plasma source (cable guns) of the plasma opening switch (POS) on Qiangguang Ⅰ generator was chosen as the study object. The plasma source performance was investigated by using charge collectors. Experimental results show that the plasma ejection density is positively correlated with the structural parameter, the distance between gun core tip and muzzle plane, and the plasma ejection velocity is negatively correlated with the parameter. The increasing rate of plasma ejection density is less than that of drive current. As far as a plasma source with tens of cable plasma guns is concerned, the influence of single cable gun's discharge dispersancy on plasma uniformity is little. Analysis of uncertainty shows that the uncertainty of measurement can be reduced by increasing the number of experiments and averaging the results. The combined standard uncertainty of plasma ejection density is less than 10%. (authors)

  9. Steam generator tube performance: experience with water-cooled nuclear power reactors during 1983 and 1984

    International Nuclear Information System (INIS)

    Tatone, O.S.; Meindl, P.; Taylor, G.F.

    1986-06-01

    A review of the performance of steam generator tubes in water-cooled nuclear power reactors showed that tubes were plugged at 47 (35.6%) of the reactors in 1983 and at 63 (42.6%) of the reactors during 1984. In 1983 and 1984 3291 and 3335 tubes, respectively, were removed from service, about the same as in 1982. The leading causes assigned to tube failure were stress corrosion cracking from the primary side and stress corrosion cracking or intergranular attack from the secondary side. In addition 5668 tubes were repaired for further service by installation of internal sleeves. Most of these were believed to have deteriorated by one of the above mechanisms or by pitting. There is a continuing trend towards high-integrity condenser tube materials at sites cooled by brackish or sea water. 31 refs

  10. Steam generator tube performance: world experience with water-cooled nuclear power reactors during 1979

    International Nuclear Information System (INIS)

    Tatone, O.S.; Pathania, R.S.

    1981-01-01

    The performance of steam generator tubes in water-cooled nuclear power reactors is reviewed for 1979. Tube failures occurred at 38 of the 93 reactors surveyed. The causes of these failures and the procedures designed to deal with them are described. The defect rate, although higher than that in 1978, was still lower than the rates of the two previous years. Methods being employed to detect defects include the increased use of multifrequency eddy-current testing and a trend to full-length inspection of all tubes. To reduce the incidence of tube failure by corrosion, plant operators are turning to full-flow condensate demineralization and more leak-resistant condenser tubes. 10 tables

  11. A high-performance micro electret power generator based on microball bearings

    International Nuclear Information System (INIS)

    Yang, Zhaohui; Wang, Jing; Zhang, Jinwen

    2011-01-01

    In this paper, a high-performance micro electret power generator fabricated by simple bulk micromachining technology is presented. It has microballs as movable bearings for harvesting changing low-frequency vibration energy from the environment. The silicon V-grooves where the microballs slide have very smooth (1 1 1) planes, and so the device is sensitive to very slight vibration and almost has no resonant frequency. A plasma-enhanced chemical vapour deposition SiO 2 /Si 3 N 4 double layer was used as the electret. The device was fabricated by simple micromachining technology suitable for mass production except for microball assembly. The influence of various frequencies and accelerations on the performance was studied in detail. The measurement results of this electret micro power generator show that the optimal load is proportional to the frequency, and inversely proportional to the acceleration. The peak-to-peak output charge and output power were 72 nC and 5.9 µW respectively at 20 Hz and 0.7 g with the optimal resistive load 626 kΩ. The work frequencies range from 100 Hz to a lower frequency (1 Hz). 112 nW can still be obtained in the minimum acceleration of 0.05 g at 10 Hz with the optimal resistive load, indicating that this device has high sensitivity. The possible application of our device in scavenging energy from low-frequency irregular movements, such as human motion, was proved by a primary experiment

  12. Thermoelectric generator experimental performance testing for wireless sensor network application in smart buildings

    Directory of Open Access Journals (Sweden)

    Al Musleh Mohamed

    2017-01-01

    Full Text Available In order to make a conventional building more efficient or smarter, systems feedbacks are essential. Such feedbacks can include real-time or logged data from various systems, such as temperature, humidity, lighting and CO2 levels. This is only possible by the use of a network of sensors which report to the building management system. Conventional sensors are limited due to wiring and infrastructure requirements. Wireless Sensor Networks (WSN however, eliminates the wiring limitations but still in certain cases require periodical battery changes and maintenance. A suitable solution for WSN limitations is to use different types of ambient energy harvesters to power battery-less sensors or alternatively to charge existing batteries so as to reduce their changing requirements. Such systems are already in place using various energy harvesting techniques. Thermoelectric Generators (TEG are one of them where the temperature gradient is used to generate electricity which is conditioned and used for WSN powering applications. Researchers in this field often face difficulty in estimating the TEG output at the low-temperature difference as manufacturers’ datasheets and performance data are not following the same standards and in most cases cover the high-temperature difference (more than 200C°. This is sufficient for industrial applications but not for WSN systems in the built environment where the temperature difference is much smaller (1-20C° is covered in this study. This paper presents a TEG experimental test setup using a temperature controlled hotplate in order to provide accurate TEG performance data at the low-temperature difference range.

  13. Performance of an Interpolated Stochastic Weather Generator in Czechia and Nebraska

    Science.gov (United States)

    Dubrovsky, M.; Trnka, M.; Hayes, M. J.; Svoboda, M. D.; Semeradova, D.; Metelka, L.; Hlavinka, P.

    2008-12-01

    Met&Roll is a WGEN-like parametric four-variate daily weather generator (WG), with an optional extension allowing the user to generate additional variables (i.e. wind and water vapor pressure). It is designed to produce synthetic weather series representing present and/or future climate conditions to be used as an input into various models (e.g. crop growth and rainfall runoff models). The present contribution will summarize recent experiments, in which we tested the performance of the interpolated WG, with the aim to examine whether the WG may be used to produce synthetic weather series even for sites having no meteorological observations. The experiments being discussed include: (1) the comparison of various interpolation methods where the performance of the candidate methods is compared in terms of the accuracy of the interpolation for selected WG parameters; (2) assessing the ability of the interpolated WG in the territories of Czechia and Nebraska to reproduce extreme temperature and precipitation characteristics; (3) indirect validation of the interpolated WG in terms of the modeled crop yields simulated by STICS crop growth model (in Czechia); and (4) indirect validation of interpolated WG in terms of soil climate regime characteristics simulated by the SoilClim model (Czechia and Nebraska). The experiments are based on observed daily weather series from two regions: Czechia (area = 78864 km2, 125 stations available) and Nebraska (area = 200520 km2, 28 stations available). Even though Nebraska exhibits a much lower density of stations, this is offset by the state's relatively flat topography, which is an advantage in using the interpolated WG. Acknowledgements: The present study is supported by the AMVIS-KONTAKT project (ME 844) and the GAAV Grant Agency (project IAA300420806).

  14. The Performance of Early-Generation Perennial Winter Cereals at 21 Sites across Four Continents

    Directory of Open Access Journals (Sweden)

    Richard C. Hayes

    2018-04-01

    Full Text Available A network of 21 experiments was established across nine countries on four continents and spanning both hemispheres, to evaluate the relative performance of early generation perennial cereal material derived from wheat, rye, and barley and to inform future breeding strategies. The experimental lines were grown in replicated single rows, and first year production and phenology characteristics as well as yield and persistence for up to three years were monitored. The study showed that the existing experimental material is all relatively short-lived (≤3 years, with environments that are milder in summer and winter generally conferring greater longevity. No pedigree was superior across this diverse network of sites although better performing lines at the higher latitude sites were generally derived from Thinopyrum intermedium. By contrast, at lower latitudes the superior lines were generally derived from Th. ponticum and Th. elongatum parentage. The study observed a poor relationship between year 1 performance and productivity in later years, highlighting the need for perennial cereal material with greater longevity to underpin future experimental evaluation, and the importance for breeding programs to emphasize post-year 1 performance in their selections. Hybrid lines derived from the tetraploid durum wheat generally showed greater longevity than derivatives of hexaploid wheat, highlighting potential for greater use of Triticum turgidum in perennial wheat breeding. We advocate a model in future breeding initiatives that develops perennial cereal genotypes for specific target environments rather than a generic product for one global market. These products may include a diversity of cultivars derived from locally adapted annual and perennial parents. In this scenario the breeding program may have access to only a limited range of adapted perennial grass parents. In other situations, such as at very high latitude environments, perennial crops derived

  15. Investigating the quality of video consultations performed using fourth generation (4G) mobile telecommunications.

    Science.gov (United States)

    Caffery, Liam J; Smith, Anthony C

    2015-09-01

    The use of fourth-generation (4G) mobile telecommunications to provide real-time video consultations were investigated in this study with the aims of determining if 4G is a suitable telecommunications technology; and secondly, to identify if variation in perceived audio and video quality were due to underlying network performance. Three patient end-points that used 4G Internet connections were evaluated. Consulting clinicians recorded their perception of audio and video quality using the International Telecommunications Union scales during clinics with these patient end-points. These scores were used to calculate a mean opinion score (MOS). The network performance metrics were obtained for each session and the relationships between these metrics and the session's quality scores were tested. Clinicians scored the quality of 50 hours of video consultations, involving 36 clinic sessions. The MOS for audio was 4.1 ± 0.62 and the MOS for video was 4.4 ± 0.22. Image impairment and effort to listen were also rated favourably. There was no correlation between audio or video quality and the network metrics of packet loss or jitter. These findings suggest that 4G networks are an appropriate telecommunication technology to deliver real-time video consultations. Variations in quality scores observed during this study were not explained by the packet loss and jitter in the underlying network. Before establishing a telemedicine service, the performance of the 4G network should be assessed at the location of the proposed service. This is due to known variability in performance of 4G networks. © The Author(s) 2015.

  16. The SSG Wave Energy Converter: Performance, Status and Recent Developments

    Directory of Open Access Journals (Sweden)

    Mariano Buccino

    2012-01-01

    Full Text Available The Sea-wave Slot-cone Generator (SSG is a Wave Energy Converter based on the wave overtopping principle; it employs several reservoirs placed on top of each other, in which the energy of incoming waves is stored as potential energy. Then, the captured water runs through turbines for electricity production. The system works under a wide spectrum of different wave conditions, giving a high overall efficiency. It can be suitable for shoreline and breakwater applications and presents particular advantages, such as sharing structure costs, availability of grid connection and recirculation of water inside the harbor, as the outlet of the turbines is on the rear part of the system. Recently, plans for the SSG pilot installations are in progress at the Svaaheia site (Norway, the port of Hanstholm (Denmark and the port of Garibaldi (Oregon, USA. In the last-mentioned two projects, the Sea-wave Slot-cone Generator technology is integrated into the outer harbor breakwater and jetty reconstruction projects. In the last years extensive studies have been performed on the hydraulic and the structural response of this converter, with the aim of optimizing the design process. The investigations have been conducted by physical model tests and numerical simulations and many results have been published on both conference proceedings and journals. The main scope of this paper is reviewing the most significant findings, to provide the reader with an organic overview on the present status of knowledge.

  17. Acute effects of the use of external instability generating devices on neuromuscular performance

    Directory of Open Access Journals (Sweden)

    Guillermo Peña García-Orea

    2016-02-01

    Full Text Available DOI: http://dx.doi.org/10.5007/1980-0037.2016v18n6p722   Physical training with the use of instability generator devices has become popular in the health area, in sport training and clinical practice (mainly in the prevention and treatment of injuries. To understand how the process of using these devices occurs and the results of their acute effects is important to guide professionals in choosing the appropriate device. The aim of this review was to present the main features of instability devices and analyze their acute effects on core muscle activation, neuromuscular performance and activation of lower and upper limbs. Studies have shown that the main acute effects of exercises performed with these devices are: 1 increased activation / muscular recruitment (especially in the middle zone or core; 2 greater co-activation of antagonist muscles (trunk, upper and lower limbs, with increased stiffness and joint stability; 3 lower force output, power and speed in extremities.

  18. Framework for generating expert systems to perform computer security risk analysis

    International Nuclear Information System (INIS)

    Smith, S.T.; Lim, J.J.

    1985-01-01

    At Los Alamos we are developing a framework to generate knowledge-based expert systems for performing automated risk analyses upon a subject system. The expert system is a computer program that models experts' knowledge about a topic, including facts, assumptions, insights, and decision rationale. The subject system, defined as the collection of information, procedures, devices, and real property upon which the risk analysis is to be performed, is a member of the class of systems that have three identifying characteristics: a set of desirable assets (or targets), a set of adversaries (or threats) desiring to obtain or to do harm to the assets, and a set of protective mechanisms to safeguard the assets from the adversaries. Risk analysis evaluates both vulnerability to and the impact of successful threats against the targets by determining the overall effectiveness of the subject system safeguards, identifying vulnerabilities in that set of safeguards, and determining cost-effective improvements to the safeguards. As a testbed, we evaluate the inherent vulnerabilities and risks in a system of computer security safeguards. The method considers safeguards protecting four generic targets (physical plant of the computer installation, its hardware, its software, and its documents and displays) against three generic threats (natural hazards, direct human actions requiring the presence of the adversary, and indirect human actions wherein the adversary is not on the premises-perhaps using such access tools as wiretaps, dialup lines, and so forth). Our automated procedure to assess the effectiveness of computer security safeguards differs from traditional risk analysis methods

  19. Performance assessment of electric power generations using an adaptive neural network algorithm

    International Nuclear Information System (INIS)

    Azadeh, A.; Ghaderi, S.F.; Anvari, M.; Saberi, M.

    2007-01-01

    Efficiency frontier analysis has been an important approach of evaluating firms' performance in private and public sectors. There have been many efficiency frontier analysis methods reported in the literature. However, the assumptions made for each of these methods are restrictive. Each of these methodologies has its strength as well as major limitations. This study proposes a non-parametric efficiency frontier analysis method based on the adaptive neural network technique for measuring efficiency as a complementary tool for the common techniques of the efficiency studies in the previous studies. The proposed computational method is able to find a stochastic frontier based on a set of input-output observational data and do not require explicit assumptions about the function structure of the stochastic frontier. In this algorithm, for calculating the efficiency scores, a similar approach to econometric methods has been used. Moreover, the effect of the return to scale of decision-making units (DMUs) on its efficiency is included and the unit used for the correction is selected by notice of its scale (under constant return to scale assumption). An example using real data is presented for illustrative purposes. In the application to the power generation sector of Iran, we find that the neural network provide more robust results and identifies more efficient units than the conventional methods since better performance patterns are explored. Moreover, principle component analysis (PCA) is used to verify the findings of the proposed algorithm

  20. Performance of Emcore Third Generation CPV Modules in the Low Latitude Marine Environment of Hawaii

    Science.gov (United States)

    Hoffman, Richard; Buie, Damien; King, David; Glesne, Thomas

    2011-12-01

    Emcore third generation concentrating photovoltaic (CPV) modules were evaluated in the low latitude location of Kihei, Hawaii. For comparison, the best available monocrystalline silicon flat panel modules were included in both dual-axis tracked and fixed mount configurations. The daily DC uncorrected efficiency value for the CPV modules averaged over the six-month performance period was 25.9% compared to 16% to 17% for the flat panels. Higher daily energy was obtained from CPV modules than tracked flat panels when daily direct solar insolation was greater than 5 kWh/m2 and more than fixed mount flat panel when direct insolation was greater than 3 kWh/m2. The module energy conversion performance was demonstrated to be predictable using a parametric model developed by Sandia National Laboratory. Soiling accumulation on module entrance surface was surprisingly rapid in the local environment. Measured energy loss rate due to soiling were two to six times larger for CPV compared to flat panel losses.

  1. Variation in motor output and motor performance in a centrally generated motor pattern

    Science.gov (United States)

    Norris, Brian J.; Doloc-Mihu, Anca; Calabrese, Ronald L.

    2014-01-01

    Central pattern generators (CPGs) produce motor patterns that ultimately drive motor outputs. We studied how functional motor performance is achieved, specifically, whether the variation seen in motor patterns is reflected in motor performance and whether fictive motor patterns differ from those in vivo. We used the leech heartbeat system in which a bilaterally symmetrical CPG coordinates segmental heart motor neurons and two segmented heart tubes into two mutually exclusive coordination modes: rear-to-front peristaltic on one side and nearly synchronous on the other, with regular side-to-side switches. We assessed individual variability of the motor pattern and the beat pattern in vivo. To quantify the beat pattern we imaged intact adults. To quantify the phase relations between motor neurons and heart constrictions we recorded extracellularly from two heart motor neurons and movement from the corresponding heart segments in minimally dissected leeches. Variation in the motor pattern was reflected in motor performance only in the peristaltic mode, where larger intersegmental phase differences in the motor neurons resulted in larger phase differences between heart constrictions. Fictive motor patterns differed from those in vivo only in the synchronous mode, where intersegmental phase differences in vivo had a larger front-to-rear bias and were more constrained. Additionally, load-influenced constriction timing might explain the amplification of the phase differences between heart segments in the peristaltic mode and the higher variability in motor output due to body shape assumed in this soft-bodied animal. The motor pattern determines the beat pattern, peristaltic or synchronous, but heart mechanics influence the phase relations achieved. PMID:24717348

  2. Next Generation Solvent Performance in the Modular Caustic Side Solvent Extraction Process - 15495

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Tara E. [Savannah River Remediation, LLC., Aiken, SC (United States); Scherman, Carl [Savannah River Remediation, LLC., Aiken, SC (United States); Martin, David [Savannah River Remediation, LLC., Aiken, SC (United States); Suggs, Patricia [Savannah River Site (SRS), Aiken, SC (United States)

    2015-01-14

    Changes to the Modular Caustic Side Solvent Extraction Unit (MCU) flow-sheet were implemented in the facility. Implementation included changing the scrub and strip chemicals and concentrations, modifying the O/A ratios for the strip, scrub, and extraction contactor banks, and blending the current BoBCalixC6 extractant-based solvent in MCU with clean MaxCalix extractant-based solvent. During the successful demonstration period, the MCU process was subject to rigorous oversight to ensure hydraulic stability and chemical/radionuclide analysis of the key process tanks (caustic wash tank, solvent hold tank, strip effluent hold tank, and decontaminated salt solution hold tank) to evaluate solvent carryover to downstream facilities and the effectiveness of cesium removal from the liquid salt waste. Results indicated the extraction of cesium was significantly more effective with an average Decontamination Factor (DF) of 1,129 (range was 107 to 1,824) and that stripping was effective. The contactor hydraulic performance was stable and satisfactory, as indicated by contactor vibration, contactor rotational speed, and flow stability; all of which remained at or near target values. Furthermore, the Solvent Hold Tank (SHT) level and specific gravity was as expected, indicating that solvent integrity and organic hydraulic stability were maintained. The coalescer performances were in the range of processing results under the BOBCalixC6 flow sheet, indicating negligible adverse impact of NGS deployment. After the Demonstration period, MCU began processing via routine operations. Results to date reiterate the enhanced cesium extraction and stripping capability of the Next Generation Solvent (NGS) flow sheet. This paper presents process performance results of the NGS Demonstration and continued operations of MCU utilizing the blended BobCalixC6-MaxCalix solvent under the NGS flowsheet.

  3. Meteosat third generation: preliminary imagery and sounding mission concepts and performances

    Science.gov (United States)

    Aminou, Donny M.; Bézy, Jean-Loup; Bensi, Paolo; Stuhlmann, Rolf; Rodriguez, Antonio

    2017-11-01

    The operational deployment of MSG-1 at the beginning of 2004, the first of a series of four Meteosat Second Generation (MSG) satellites, marks the start of a new era in Europe for the meteorological observations from the geostationary orbit. This new system shall be the backbone of the European operational meteorological services up to at least 2015. The time required for the definition and the development of new space systems as well as the approval process of such complex programs implies to plan well ahead for the future missions. EUMETSAT have initiated in 2001, with ESA support, a User Consultation Process aiming at preparing for a future operational geostationary meteorological satellite system in the post-MSG era, named Meteosat Third Generation (MTG). The first phase of the User Consultation Process was devoted to the definition and consolidation of end user requirements and priorities in the field of Nowcasting and Very Short Term Weather Forecasting (NWC), Medium/Short Range global and regional Numerical Weather Prediction (NWP), Climate and Air Composition Monitoring and to the definition of the relevant observation techniques. After an initial post-MSG mission study (2003-2004) where preliminary instrument concepts were investigated allowing in the same time to consolidate the technical requirements for the overall system study, a MTG pre-phase A study has been performed for the overall system concept, architecture and programmatic aspects during 2004-2005 time frame. This paper provides an overview of the outcome of the MTG sensor concept studies conducted in the frame of the pre-phase A. It namely focuses onto the Imaging and Sounding Missions, highlights the resulting instrument concepts, establishes the critical technologies and introduces the study steps towards the implementation of the MTG development programme.

  4. New generation neonatal high frequency ventilators: effect of oscillatory frequency and working principles on performance.

    Science.gov (United States)

    Grazioli, Serge; Karam, Oliver; Rimensberger, Peter C

    2015-03-01

    Several new generation neonatal ventilators that incorporate conventional as well as high frequency ventilation (HFOV) have appeared on the market. Most of them offer the possibility to use HFOV in a volume-targeted mode, despite absence of any preclinical data. With a bench test, we evaluated the performances of 4 new neonatal HFOV devices and compared them to the SensorMedics HFOV device. Expiratory tidal volumes (V(T)) were measured for various ventilator settings and lung characteristics (ie, modifications of compliance and resistance of the system), to mimic several clinical conditions of pre-term and term infants. Increasing the frequency proportionally decreased the V(T) for all the ventilators, although the magnitude of the decrease was highly variable between ventilators. At 15 Hz and a pressure amplitude of 60 cm H2O, the delivered V(T) ranged from 3.5 to 5.9 mL between devices while simulating pre-term infant conditions and from 2.6 to 6.3 mL while simulating term infant conditions. Activating the volume-targeted mode in the 3 machines that offer this mode allowed the V(T) to remain constant over the range of frequencies and with changes of lung mechanical properties, for pre-term infant settings only while targeting a V(T) of 1 mL. These new generation neonatal ventilators were able to deliver adequate V(T) under pre-term infant, but not term infant respiratory system conditions. The clinical relevance of these findings will need to be determined by further studies. Copyright © 2015 by Daedalus Enterprises.

  5. Effect of wind generation system types on Micro-Grid (MG) fault performance during both standalone and grid connected modes

    International Nuclear Information System (INIS)

    Kamel, Rashad M.

    2014-01-01

    Highlights: • This paper evaluated the effects of different wind system types on fault performance of Micro-Grid. • Both standalone and grid connected modes are considered. • The MG earthing system configuration is taken in consideration. - Abstract: Recently, there are three wind generation (WG) system types. The first type is called Fixed Speed Wind Generation (FSWG) system, which employs squirrel cage induction generators. Double Fed Induction Generator (DFIG) is utilized in the second type. The third type is called Full Converter Wind Generation (FCWG) system, which is interfaced with Micro-Grid (MG) through a back to back converter. During fault occurrence, each WG has its performance and characteristics which are determined by the generator physical characteristics and the MG earthing system configuration. For some WG types, the fault current depends also on the control algorithm of the power converter. The main target of this paper is to investigate and estimate how the fault performance of MG during both standalone and grid-connected modes is influenced by the type of WG. It is found during standalone mode that the type of the employed WG has a dominant impact on the MG performance under fault disturbance. On the contrary, the type of the employed WG has a negligible effect on the MG fault performance during grid-connected mode. This is because the main grid contributes most of the fault current. Effects of earthing system type on MG performance are highlighted

  6. Performance of the electrical generator cell by the ferrous alloys of printed circuit board scrap and Iron Metal 1020

    Science.gov (United States)

    Sahan, Y.; Sudarsono, S.; Silviana, E.; Chairul; Wisrayetti

    2018-04-01

    Galvani cell is one of thealternative energy. This cell can be used as an electric resources. In this research, the generator cell was designed and builds to generate the electric. The generator cell consisted of the iron metal 1020 were used as anode, the ferrous alloys of printed circuit board scrapwas then used as chatode, and NaCl solution as an electrolyte. The aim of this research is to estimate the performance of this generator cell by using variation of NaCl concentration (i.e. 1%, 3%, 5%, 7%, and 9%) with the electrodes pair ( 1 and 8 pairs). The performance of the cell was measured with a multi tester equipment and a LED bulb (5-watt 3Volt). The Results shown that the generator cell can produce the electric power of 3.679 Volt maximally by using NaCl 9% and 8 electrode pairs applied for this condition.

  7. Performance analysis of an Integrated Solar Combined Cycle using Direct Steam Generation in parabolic trough collectors

    International Nuclear Information System (INIS)

    Montes, M.J.; Rovira, A.; Munoz, M.; Martinez-Val, J.M.

    2011-01-01

    Highlights: → Solar hybridization improves the performance of CCGT in a very hot and dry weather. → The scheme analyzed is a DSG parabolic trough field coupled to the Rankine cycle. → An annual simulation has been carried out for two locations: Almeria and Las Vegas. → Economical analysis shows that this scheme is a cheaper way to exploit solar energy. → For that, solar hybridization must be limited to a small fraction of the CCGT power. - Abstract: The contribution of solar thermal power to improve the performance of gas-fired combined cycles in very hot and dry environmental conditions is analyzed in this work, in order to assess the potential of this technique, and to feature Direct Steam Generation (DSG) as a well suited candidate for achieving very good results in this quest. The particular Integrated Solar Combined Cycle (ISCC) power plant proposed consists of a DSG parabolic trough field coupled to the bottoming steam cycle of a Combined Cycle Gas Turbine (CCGT) power plant. For this analysis, the solar thermal power plant performs in a solar dispatching mode: the gas turbine always operates at full load, only depending on ambient conditions, whereas the steam turbine is somewhat boosted to accommodate the thermal hybridization from the solar field. Although the analysis is aimed to studying such complementary effects in the widest perspective, two relevant examples are given, corresponding to two well-known sites: Almeria (Spain), with a mediterranean climate, and Las Vegas (USA), with a hot and dry climate. The annual simulations show that, although the conventional CCGT power plant works worse in Las Vegas, owing to the higher temperatures, the ISCC system operates better in Las Vegas than in Almeria, because of solar hybridization is especially well coupled to the CCGT power plant in the frequent days with great solar radiation and high temperatures in Las Vegas. The complementary effect will be clearly seen in these cases, because the thermal

  8. Effect of pole number and slot number on performance of dual rotor permanent magnet wind power generator using ferrite magnets

    Directory of Open Access Journals (Sweden)

    Peifeng Xu

    2017-05-01

    Full Text Available Dual rotor permanent magnet (DRPM wind power generator using ferrite magnets has the advantages of low cost, high efficiency, and high torque density. How to further improve the performance and reduce the cost of the machine by proper choice of pole number and slot number is an important problem to be solved when performing preliminarily design a DRPM wind generator. This paper presents a comprehensive performance comparison of a DRPM wind generator using ferrite magnets with different slot and pole number combinations. The main winding factors are calculated by means of the star of slots. Under the same machine volume and ferrite consumption, the flux linkage, back-electromotive force (EMF, cogging torque, output torque, torque pulsation, and losses are investigated and compared using finite element analysis (FEA. The results show that the slot and pole number combinations have an important impact on the generator properties.

  9. Modeling and performance analysis of a concentrated photovoltaic–thermoelectric hybrid power generation system

    International Nuclear Information System (INIS)

    Lamba, Ravita; Kaushik, S.C.

    2016-01-01

    Highlights: • Thermodynamic model of concentrated photovoltaic–thermoelectric system is analysed. • Thomson effect reduces the power output of PV, TE and hybrid PV–TEG system. • Effect of thermocouple number, irradiance, PV and TE current have been studied. • The optimum concentration ratio for maximum power output has been found out. • The overall efficiency and power output of hybrid PV–TEG system has been improved. - Abstract: In this study, a thermodynamic model for analysing the performance of a concentrated photovoltaic–thermoelectric generator (CPV–TEG) hybrid system including Thomson effect in conjunction with Seebeck, Joule and Fourier heat conduction effects has been developed and simulated in MATALB environment. The expressions for calculating the temperature of photovoltaic (PV) module, hot and cold sides of thermoelectric (TE) module are derived analytically as well. The effect of concentration ratio, number of thermocouples in TE module, solar irradiance, PV module current and TE module current on power output and efficiency of the PV, TEG and hybrid PV–TEG system have been studied. The optimum concentration ratio corresponding to maximum power output of the hybrid system has been found out. It has been observed that by considering Thomson effect in TEG module, the power output of the PV, TE and hybrid PV–TEG systems decreases and at C = 1 and 5, it reduces the power output of hybrid system by 0.7% and 4.78% respectively. The results of this study may provide basis for performance optimization of a practical irreversible CPV–TEG hybrid system.

  10. Capabilities and performance of Elmer/Ice, a new-generation ice sheet model

    Directory of Open Access Journals (Sweden)

    O. Gagliardini

    2013-08-01

    Full Text Available The Fourth IPCC Assessment Report concluded that ice sheet flow models, in their current state, were unable to provide accurate forecast for the increase of polar ice sheet discharge and the associated contribution to sea level rise. Since then, the glaciological community has undertaken a huge effort to develop and improve a new generation of ice flow models, and as a result a significant number of new ice sheet models have emerged. Among them is the parallel finite-element model Elmer/Ice, based on the open-source multi-physics code Elmer. It was one of the first full-Stokes models used to make projections for the evolution of the whole Greenland ice sheet for the coming two centuries. Originally developed to solve local ice flow problems of high mechanical and physical complexity, Elmer/Ice has today reached the maturity to solve larger-scale problems, earning the status of an ice sheet model. Here, we summarise almost 10 yr of development performed by different groups. Elmer/Ice solves the full-Stokes equations, for isotropic but also anisotropic ice rheology, resolves the grounding line dynamics as a contact problem, and contains various basal friction laws. Derived fields, like the age of the ice, the strain rate or stress, can also be computed. Elmer/Ice includes two recently proposed inverse methods to infer badly known parameters. Elmer is a highly parallelised code thanks to recent developments and the implementation of a block preconditioned solver for the Stokes system. In this paper, all these components are presented in detail, as well as the numerical performance of the Stokes solver and developments planned for the future.

  11. Overtopping of Berm Breakwaters Evaluation of Overtopping Formula

    DEFF Research Database (Denmark)

    Andersen, Thomas Lykke; Burcharth, H. F.

    2005-01-01

    The berm breakwater concept is basicly rather old, but was not used very much until it was “reinvented” in the early 1980’ties, when a slope protection for an airfield runway extending into the sea in the Alutian Islands, Alaska was designed.......The berm breakwater concept is basicly rather old, but was not used very much until it was “reinvented” in the early 1980’ties, when a slope protection for an airfield runway extending into the sea in the Alutian Islands, Alaska was designed....

  12. Status report on performance of radioisotope thermoelectric generators using silicon germanium thermoelectric elements

    International Nuclear Information System (INIS)

    Bennett, G.L.; Campbell, R.W.; Putnam, L.R.; Hemler, R.J.

    1994-01-01

    Three general-purpose heat source radioisotope thermoelectric generators (GPHS-RTGs) are currently in use in space: two on board the Galileo spacecraft on its way to Jupiter and one on the Ulysses spacecraft exploring the polar regions of the Sun. The GPHS-RTG was designed to provide at least 285 W(e) at the beginning of mission (BOM) within a mass constraint of 56 kg and an overall size envelope of 42.2 cm in diameter and 114 cm in length. The Galileo spacecraft, which as already sent back exciting scientific information on Venus, Earth, and the asteroids Gaspra and Ida, carries two GPHS-RTGs which operate at 30 V. The Ulysses spacecraft, which has already successfully swung past Jupiter on its way to the southern polar regions of the Sun, carries one GPHS-RTG which operates at 28 V. The analyses presented in the paper show that both Galileo and Ulysses will have sufficient power for the baseline missions and analyses are under way to determine the power available for an extended Ulysses mission out to the year 2002. Ten other silicon-germanium-based RTGs on the LES 8/9 and Voyager 1/2 spacecraft have completed their prime missions and are now successfully performing extended missions

  13. Performance investigation on dissipative dielectric elastomer generators with a triangular energy harvesting scheme

    Science.gov (United States)

    Fan, Peng; Chen, Hualing; Li, Bo; Wang, Yongquan

    2017-11-01

    In this letter, a theoretical framework describing an energy harvesting cycle including the loss of tension (LT) process is proposed to investigate the energy harvesting performance of a dielectric elastomer generator (DEG) with a triangular energy harvesting scheme by considering material viscosity and leakage current. As the external force that is applied to the membrane decreases, the membrane is relaxed. When the external force decreases to zero, the condition is known as LT. Then the membrane undergoing LT can further relax, which is referred to as the LT process. The LT process is usually ignored in theoretical analysis but observed from energy harvesting experiments of DEGs. It is also studied how shrinking time and transfer capacitor affect the energy conversion of a DEG. The results indicate that energy density and conversion efficiency can be simultaneously improved by choosing appropriate shrinking time and transfer capacitor to optimize the energy harvesting cycle. The results and methods are expected to provide guidelines for the optimal design and assessment of DEGs.

  14. Performance evaluation of secured DICOM image communication with next generation internet protocol IPv6

    Science.gov (United States)

    Yu, Fenghai; Zhang, Jianguo; Chen, Xiaomeng; Huang, H. K.

    2005-04-01

    Next Generation Internet (NGI) technology with new communication protocol IPv6 emerges as a potential solution for low-cost and high-speed networks for image data transmission. IPv6 is designed to solve many of the problems of the current version of IP (known as IPv4) with regard to address depletion, security, autoconfiguration, extensibility, and more. We choose CTN (Central Test Node) DICOM software developed by The Mallinckrodt Institute of Radiology to implement IPv6/IPv4 enabled DICOM communication software on different operating systems (Windows/Linux), and used this DICOM software to evaluate the performance of the IPv6/IPv4 enabled DICOM image communication with different security setting and environments. We compared the security communications of IPsec with SSL/TLS on different TCP/IP protocols (IPv6/IPv4), and find that there are some trade-offs to choose security solution between IPsec and SSL/TLS in the security implementation of IPv6/IPv4 communication networks.

  15. Establishment of Next-Generation Neurosurgery Research and Training Laboratory with Integrated Human Performance Monitoring.

    Science.gov (United States)

    Bernardo, Antonio

    2017-10-01

    Quality of neurosurgical care and patient outcomes are inextricably linked to surgical and technical proficiency and a thorough working knowledge of microsurgical anatomy. Neurosurgical laboratory-based cadaveric training is essential for the development and refinement of technical skills before their use on a living patient. Recent biotechnological advances including 3-dimensional (3D) microscopy and endoscopy, 3D printing, virtual reality, surgical simulation, surgical robotics, and advanced neuroimaging have proved to reduce the learning curve, improve conceptual understanding of complex anatomy, and enhance visuospatial skills in neurosurgical training. Until recently, few means have allowed surgeons to obtain integrated surgical and technological training in an operating room setting. We report on a new model, currently in use at our institution, for technologically integrated surgical training and innovation using a next-generation microneurosurgery skull base laboratory designed to recreate the setting of a working operating room. Each workstation is equipped with a 3D surgical microscope, 3D endoscope, surgical drills, operating table with a Mayfield head holder, and a complete set of microsurgical tools. The laboratory also houses a neuronavigation system, a surgical robotic, a surgical planning system, 3D visualization, virtual reality, and computerized simulation for training of surgical procedures and visuospatial skills. In addition, the laboratory is equipped with neurophysiological monitoring equipment in order to conduct research into human factors in surgery and the respective roles of workload and fatigue on surgeons' performance. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Numerical and Experimental Studies on Nonlinear Dynamics and Performance of a Bistable Piezoelectric Cantilever Generator

    Directory of Open Access Journals (Sweden)

    Kangkang Guo

    2015-01-01

    Full Text Available A piezo-magneto-elastically coupled distributed-parameter model of a bistable piezoelectric cantilever generator is developed by using the generalized Hamilton principle. The influence of the spacing between two adjacent magnets on the static bifurcation characteristics of the system is studied and the range of magnet spacing corresponding to the bistable states is obtained. Numerical and experimental studies are carried out to analyze the bifurcation, response characteristics, and their impact on the electrical output performance under varying external excitations. Results indicate that interwell limit cycle motion of the beam around the two centers corresponds to optimum power output; interwell chaotic motion and multiperiodic motion including intrawell oscillations are less effective. At a given frequency, the phenomena of symmetric-breaking and amplitude-phase modulation are observed with increase of base excitation. Both period-doubling bifurcation and intermittency routes to chaotic motion in the bistable system are found. It can be observed that the power output is not proportional to the excitation level because of the bifurcation behaviours.

  17. Device performance of in situ steam generated gate dielectric nitrided by remote plasma nitridation

    International Nuclear Information System (INIS)

    Al-Shareef, H. N.; Karamcheti, A.; Luo, T. Y.; Bersuker, G.; Brown, G. A.; Murto, R. W.; Jackson, M. D.; Huff, H. R.; Kraus, P.; Lopes, D.

    2001-01-01

    In situ steam generated (ISSG) oxides have recently attracted interest for use as gate dielectrics because of their demonstrated reliability improvement over oxides formed by dry oxidation. [G. Minor, G. Xing, H. S. Joo, E. Sanchez, Y. Yokota, C. Chen, D. Lopes, and A. Balakrishna, Electrochem. Soc. Symp. Proc. 99-10, 3 (1999); T. Y. Luo, H. N. Al-Shareef, G. A. Brown, M. Laughery, V. Watt, A. Karamcheti, M. D. Jackson, and H. R. Huff, Proc. SPIE 4181, 220 (2000).] We show in this letter that nitridation of ISSG oxide using a remote plasma decreases the gate leakage current of ISSG oxide by an order of magnitude without significantly degrading transistor performance. In particular, it is shown that the peak normalized transconductance of n-channel devices with an ISSG oxide gate dielectric decreases by only 4% and the normalized drive current by only 3% after remote plasma nitridation (RPN). In addition, it is shown that the reliability of the ISSG oxide exhibits only a small degradation after RPN. These observations suggest that the ISSG/RPN process holds promise for gate dielectric applications. [copyright] 2001 American Institute of Physics

  18. An improvement of SiC insulator performances for MHD generator channels

    International Nuclear Information System (INIS)

    Okuo, T.; Ookouchi, T.; Aoki, Y.

    1988-01-01

    A water cooled ceramic-metal bonded wall element has been developed for a coal combustion MHD generator channels. It was shown to have excellent characters of stability under high heat flux and thermal shock conditions and good electrical insulation performance in the splash test stand and the small scale MHD simulation channel of ETL COM Fired Facility. Temperature of the compliant and brazed layer rises significantly with heat flux, and cause troubles such as oxidation, corrosion and deterioration of strength of the compliant material. Not only an application for the ceramics-metal bonding with high reliability, but also an improvement of allowable heat flux is possible. New compliant material made of grooved copper and a high reliable metallizing and brazing method were developed. It will make possible raising the limitation of allowable heat flux up to 1,000 W/cm 2 . Through this research, the compatibility of the grooved copper compliant structure was proved and a design concept obtained to construct a highly efficient, water cooled SiC insulator

  19. Generation and performance assessment of the global TanDEM-X digital elevation model

    Science.gov (United States)

    Rizzoli, Paola; Martone, Michele; Gonzalez, Carolina; Wecklich, Christopher; Borla Tridon, Daniela; Bräutigam, Benjamin; Bachmann, Markus; Schulze, Daniel; Fritz, Thomas; Huber, Martin; Wessel, Birgit; Krieger, Gerhard; Zink, Manfred; Moreira, Alberto

    2017-10-01

    The primary objective of the TanDEM-X mission is the generation of a global, consistent, and high-resolution digital elevation model (DEM) with unprecedented global accuracy. The goal is achieved by exploiting the interferometric capabilities of the two twin SAR satellites TerraSAR-X and TanDEM-X, which fly in a close orbit formation, acting as an X-band single-pass interferometer. Between December 2010 and early 2015 all land surfaces have been acquired at least twice, difficult terrain up to seven or eight times. The acquisition strategy, data processing, and DEM calibration and mosaicking have been systematically monitored and optimized throughout the entire mission duration, in order to fulfill the specification. The processing of all data has finally been completed in September 2016 and this paper reports on the final performance of the TanDEM-X global DEM and presents the acquisition and processing strategy which allowed to obtain the final DEM quality. The results confirm the outstanding global accuracy of the delivered product, which can be now utilized for both scientific and commercial applications.

  20. Microturbogas cogeneration systems for distributed generation: Effects of ambient temperature on global performance and components’ behavior

    International Nuclear Information System (INIS)

    Caresana, F.; Pelagalli, L.; Comodi, G.; Renzi, M.

    2014-01-01

    Highlights: • Electrical power reduces with temperature, heat recovery remains almost constant. • Thermal-to-electrical power ratio increases with ambient temperature. • Not only the density of sucked air decreases but also its volumetric flow. • Putting a limit to shaft speed causes TIT to decrease with ambient temperature. • Power reduction with ambient temperature more than doubles that of great GTs. - Abstract: Microturbines (MGTs) are a relatively new technology that is currently attracting a lot of interest in the distributed generation market. Particularly interesting is their use as backup source for integrating photovoltaic panels or/and wind turbines in hybrid systems. In this case the sensitivity to ambient conditions of the MGT adds to that of the renewables and the knowledge of the effects of ambient conditions on its performance becomes a key subject both for the sizing of the energy system and for its optimal dynamic control. Although the dependence of medium/large gas turbines performance on atmospheric conditions is well known and documented in literature, there are very limited reports available on MGTs and they regard only global parameters. The paper aims at filling this lack of information by analyzing the ambient temperature effect on the global performance of an MGT in cogeneration arrangement and by entering in detail into its machines’ behavior. A simulation code, tuned on experimental data, is used for this purpose. Starting from the nominal ISO conditions, electrical power output is shown to decrease with ambient temperature at a rate of about 1.22%/°C, due to a reduction of both air density and volumetric flow. Meanwhile, thermal to electrical power ratio increases at a rate of about 1.30%/°C. As temperature increases compressor delivers less air at a lower pressure, and the turbine expansion ratio and mass flow reduce accordingly. With the in-use control system the turbine inlet temperature reduces at a rate of 0.07%/

  1. Flapping foil power generator performance enhanced with a spring-connected tail

    Science.gov (United States)

    Liu, Zhengliang; Tian, Fang-Bao; Young, John; Lai, Joseph C. S.

    2017-12-01

    The flexibility effects on the performance of a flapping foil power generator are numerically studied by using the immersed boundary-lattice Boltzmann method at a Reynolds number of 1100. The flapping foil system consists of a rigid NACA0015 foil undergoing harmonic pitch and plunge motions and a passively actuated flat plate pinned to the trailing edge of the rigid foil. The flexibility is modeled by a torsional spring model at the conjuncture of the rigid foil and the tail. Here, a parametric study on mass density and natural frequency is conducted under the optimum kinematic condition of the rigid system identified from the literature and numerical simulations made for reduced frequency f* = 0.04-0.24 and pitch amplitude θ0 = 40°-90°. Four typical cases are discussed in detail by considering time histories of hydrodynamic loads and tail deformations under the optimal and non-optimal kinematic conditions. Results show that under the rigid-system optimal kinematic condition, a tail with appropriate mass density (μ = 0.60) and resonant frequency ( fr*=1.18 ) can improve the maximum efficiency by 7.24% accompanied by an increase of 6.63% in power compared to those of a rigid foil with a rigid tail. This is because the deflection of the tail reduces the low pressure region on the pressure surface (i.e., the lower surface during the upstroke or the upper surface during the downstroke) caused by the leading edge vortex after the stroke reversal, resulting in a higher efficiency. At high flapping frequencies, a spring-connected tail ( fr*=0.13 ) eliminates the large spike in the moment observed in high stiffness cases, reducing the power required for the pitch motion, resulting in 117% improvement in efficiency over that with a rigid tail at a reduced frequency of 0.24.

  2. Coal-fired high performance power generating system. Quarterly progress report

    Energy Technology Data Exchange (ETDEWEB)

    1992-07-01

    The goals of the program are to develop a coal-fired high performance power generation system (HIPPS) by the year 2000 that is capable of > 47% thermal efficiency; NO{sub x} SO {sub x} and Particulates < 25% NSPS; Cost of electricity 10% lower; coal > 65% of heat input and all solid wastes benign. In order to achieve these goals our team has outlined a research plan based on an optimized analysis of a 250 MW{sub e} combined cycle system applicable to both frame type and aeroderivative gas turbines. Under the constraints of the cycle analysis we have designed a high temperature advanced furnace (HITAF) which integrates several combustor and air heater designs with appropriate ash management procedures. Most of this report discusses the details of work on these components, and the R&D Plan for future work. The discussion of the combustor designs illustrates how detailed modeling can be an effective tool to estimate NO{sub x} production, minimum burnout lengths, combustion temperatures and even particulate impact on the combustor walls. When our model is applied to the long flame concept it indicates that fuel bound nitrogen will limit the range of coals that can use this approach. For high nitrogen coals a rapid mixing, rich-lean, deep staging combustor will be necessary. The air heater design has evolved into two segments: a convective heat exchanger downstream of the combustion process; a radiant panel heat exchanger, located in the combustor walls; The relative amount of heat transferred either radiatively or convectively will depend on the combustor type and the ash properties.

  3. Performance of ammonia–water based cycles for power generation from low enthalpy heat sources

    International Nuclear Information System (INIS)

    Mergner, Hanna; Weimer, Thomas

    2015-01-01

    Cost efficient power generation from low temperature heat sources requires an optimal usage of the available heat. In addition to the ORC (Organic Rankine Cycles), cycles with ammonia and water as working fluid show promising results regarding efficiency. Due to their non-isothermal phase change, mixtures can adapt well to a liquid heat source temperature profile and reduce the exergetic losses. In this analysis thermodynamic calculations on the layouts of two existing ammonia–water cycles are compared: a geothermal power plant based on a Siemens’ patent and a modified lab plant based on a patent invented by Kalina (KCS-34). The difference between the two cycles is the position of the internal heat recovery. Cycle simulations were carried out at defined boundary conditions in order to identify optimal operation parameters. For the selected heat source of 393.15 K (hot water) the ammonia mass fraction between 80% and 90% results in the best performance in both configurations. In general, the layout of Siemens achieves a slightly better efficiency compared to the KCS-34. Compared to an ORC using R245fa as working fluid, the exergetic efficiency can be increased by the ammonia/water based cycles by approximately 25%. - Highlights: • Two NH 3 /H 2 O based cycles based on existing plants are analyzed and compared. • A simple KCS-34 focuses on a high enthalpy difference at the turbine. • The Kalina cycle of a Siemens patent KC SG1 runs on a high vapor mass flow. • The layout of the KC SG1 shows slightly better results compared to the KCS-34. • NH 3 /H 2 O cycles show an efficiency increase compared to a regular ORC with R245fa

  4. Learner-Generated Content and Engagement in Second Language Task Performance

    Science.gov (United States)

    Lambert, Craig; Philp, Jenefer; Nakamura, Sachiko

    2017-01-01

    This study investigates the benefits of designing second language (L2) learning tasks to operate on learner-generated content (related to actual content in their lives and experiences) as opposed to teacher-generated content typical of current approaches to L2 task design (fictitious ideas and events created to provide an opportunity for…

  5. Influence of Buoyancy Control Performance on Power Production by the Wave Dragon Nissum Bredning Prototype

    DEFF Research Database (Denmark)

    Kofoed, Jens Peter; Tedd, James; Friis-Madsen, E.

    2007-01-01

    This paper reports on the real sea performance of the buoyancy control system of Wave Dragon, a floating wave energy converter using the overtopping principle. The device operates with the full independent control system which has been tested during three years of operation. The impact of the buo...... of the buoyancy control system performance on the power production is noted. This provides motivation and a target for improved control algorithms....

  6. Evaluation of preparation and performance of gel column 99Tcm generators based on zirconium molybdate - 99Mo

    International Nuclear Information System (INIS)

    Saraswathy, P.; Sarkar, S.K.; Patel, R.R.; Arora, S.S.; Arjun, G.; Narasimhan, D.V.S.; Ramamoorthy, N.

    1998-01-01

    In view of the importance and relevance of zirconium molybdate (ZrMo) based gel generators for 99 Tc m , developed first by Australian scientists, particularly for developing nations having production capability for neutron activated 99 Mo, work has been carried out in our centre towards optimisation of the preparatory conditions. Appropriate facilities have been set up for safe, reliable and regular manufacture of such 99 Tc m gel generators on a small scale based on our earlier successful attempts on the approach for process standardisation. The results of our extensive evaluation, including for clinical use, are reported here. Following the regular procedure standardised by us earlier, 9 lots of 99 Mo were converted in ZrMo gel adopting aseptic practices and two different techniques for drying the ZrMo cake - heated air at 60-80 deg. C and microwave drying at 385 watts. The ZrMo granules obtained after further processing were loaded onto generator assemblies. 10 g molybdenum was handled in each batch of gel conversion, while typically 2 g Mo was used per generator column, except in the case of demonstration of higher capacity generators. The generator performance was evaluated systematically over nearly 15 days, in terms of rapidity and smoothness of elution, 99 Tc m elution yield and quality of eluted pertechnetate. The consistent results of over 60% (Max. 90%) yield of 99 Tc m , -3 % 99 Mo breakthrough, >98% radiochemical purity of pertechnetate, 99 Tc m compounds etc. indicated satisfactory quality of pertechnetate, comparable to that obtained by conventional generator systems. 12 such generators, containing up to 18.5 GBq 99 Mo, supplied for clinical use and evaluated at two hospital radiopharmacies showed satisfactory generator performance. The applicability for preparing larger capacity generators for centralised radiopharmacies and feasibility to achieve reduced process time and ease of control by using microwave oven drying have been established. (author)

  7. Steam generator materials performance in high temperature gas-cooled reactors

    International Nuclear Information System (INIS)

    Chafey, J.E.; Roberts, D.I.

    1980-11-01

    This paper reviews the materials technology aspects of steam generators for HTGRs which feature a graphite-moderated, uranium-thorium, all-ceramic core and utilizes high-pressure helium as the primary coolant. The steam generators are exposed to gas-side temperatures approaching 760 0 C and produce superheated steam at 538 0 C and 16.5 MPa (2400 psi). The prototype Peach Bottom I 40-MW(e) HTGR was operated for 1349 EFPD over 7 years. Examination after decommissioning of the U-tube steam generators and other components showed the steam generators to be in very satisfactory condition. The 330-MW(e) Fort St. Vrain HTGR, now in the final stages of startup, has achieved 70% power and generated more than 1.5 x 10 6 MWh of electricity. The steam generators in this reactor are once-through units of helical configuration, requiring a number of new materials factors including creep-fatigue and water chemistry control. Current designs of larger HTGRs also feature steam generators of helical once-through design. Materials issues that are important in these designs include detailed consideration of time-dependent behavior of both base metals and welds, as required by current American Society of Mechanical Engineers (ASME) Code rules, evaluation of bimetallic weld behavior, evaluation of the properties of large forgings, etc

  8. Improving performance of two-phase natural circulation loops by reducing of entropy generation

    International Nuclear Information System (INIS)

    Goudarzi, N.; Talebi, S.

    2015-01-01

    This paper aims to investigate the effects of various parameters on stability behavior and entropy generation through a two-phase natural circulation loop. Two-phase natural circulation systems have low driving head and, consequently, low heat removal capability. To have a higher thermodynamic efficiency, in addition to the stability analysis, minimization of entropy generation by loop should be taken into account in the design of these systems. In the present study, to investigate the stability behavior, the non-linear method (known as the direct solution method or time domain method) which is able to simulate the uniform and non-uniform diameter loops, was applied. To best calculate entropy generation rates, the governing equations of the entropy generation were solved analytically. The effects of various parameters such as operating conditions and geometrical dimensions on the stability behavior and the entropy generation in the two-phase natural circulation loop were then analyzed. - Highlights: • Effects of all important parameters on entropy generation of a loop are studied. • The governing equations of the entropy generation are solved analytically. • Effects of all important parameters on stability of a loop are investigated. • Improvement of two-phase natural circulation loop is investigated.

  9. Performance of the 1 kW thermoelectric generator for diesel engines

    International Nuclear Information System (INIS)

    Bass, J.C.; Elsner, N.B.; Leavitt, F.A.

    1994-01-01

    Hi-Z Technology, Inc. (Hi-Z) has been developing a 1 kW thermoelectric generator for class eight Diesel truck engines under U.S. Department of Energy and California Energy Commission funding since 1992. The purpose of this generator is to replace the currently used shaft-driven alternator by converting part of the waste heat in the engine's exhaust directly to electricity. The preliminary design of this generator was reported at the 1992 meeting of the XI-ICT in Arlington, Texas. This paper will report on the final mechanical, thermal and thermoelectric design of this generator. The generator uses seventy-two of Hi-Z's 13 Watt bismuth-telluride thermoelectric modules for energy conversion. The number of modules and their arrangement has remained constant through the program. The 1 kW generator was tested on several engines during the development process. Many of the design features were changed during this development as more information was obtained. We have only recently reached our design goal of 1 kW output. The output parameters of the generator are reported. copyright 1995 American Institute of Physics

  10. Performance Analysis of Generating Function Approach for Optimal Reconfiguration of Formation Flying

    Directory of Open Access Journals (Sweden)

    Kwangwon Lee

    2013-03-01

    Full Text Available The use of generating functions for solving optimal rendezvous problems has an advantage in the sense that it does not require one to guess and iterate the initial costate. This paper presents how to apply generating functions to analyze spacecraft optimal reconfiguration between projected circular orbits. The series-based solution obtained by using generating functions demonstrates excellent convergence and approximation to the nonlinear reference solution obtained from a numerical shooting method. These favorable properties are expected to hold for analyzing optimal formation reconfiguration under perturbations and non-circular reference orbits.

  11. Numerical study on thermoelectric–hydraulic performance of a thermoelectric power generator with a plate-fin heat exchanger with longitudinal vortex generators

    International Nuclear Information System (INIS)

    Ma, Ting; Lu, Xing; Pandit, Jaideep; Ekkad, Srinath V.; Huxtable, Scott T.; Deshpande, Samruddhi; Wang, Qiu-wang

    2017-01-01

    Highlights: • LVGs are proposed to enhance thermal–electrical conversion performance of TEGs. • Open circuit voltage of TEGs with LVGs is increased by 41–75% in baseline cases. • Reynolds number and hot-side inlet temperature have significant effects on TEGs. • Cold-side temperature has a smaller effect on TEGs. - Abstract: In this paper, the effect of longitudinal vortex generators (LVGs) on the performance of a thermoelectric power generator (TEG) with a plate-fin heat exchanger is investigated. A fluid-thermal-electric multi-physics coupled model for the TEG is established on the COMSOL® platform, in which the Seebeck, Peltier, Thomson, and Joule heating effects are taken into account. The equivalent thermal–electrical properties of the thermoelectric (TE) module are used in the numerical simulation. The results indicate that the LVGs produce complex three-dimensional vortices in the cross section downstream from the LVGs, thus enhancing the heat transfer and electric performance compared to a TEG without LVGs. Under baseline operating conditions, the heat input and open circuit voltage of the TEG with LVGs are increased by 41–75% compared to a TEG with smooth channel. The simulations also show that the Reynolds number and hot-side inlet temperature have significant effects on the net power and thermal efficiency of the TEG, but the cold-side temperature has a smaller effect. Additionally, the performance of the TEG under a constant heat transfer coefficient boundary condition is almost the same as the performance under a constant temperature boundary condition. Overall, this work demonstrates that LVGs have great potential to enhance the performance of TEGs for waste heat recovery from vehicle exhaust.

  12. Performance analyses of a hybrid geothermal–fossil power generation system using low-enthalpy geothermal resources

    International Nuclear Information System (INIS)

    Liu, Qiang; Shang, Linlin; Duan, Yuanyuan

    2016-01-01

    Highlights: • Geothermal energy is used to preheat the feedwater in a coal-fired power unit. • The performance of a hybrid geothermal–fossil power generation system is analyzed. • Models for both parallel and serial geothermal preheating schemes are presented. • Effects of geothermal source temperatures, distances and heat losses are analyzed. • Power increase of the hybrid system over an ORC and tipping distance are discussed. - Abstract: Low-enthalpy geothermal heat can be efficiently utilized for feedwater preheating in coal-fired power plants by replacing some of the high-grade steam that can then be used to generate more power. This study analyzes a hybrid geothermal–fossil power generation system including a supercritical 1000 MW power unit and a geothermal feedwater preheating system. This study models for parallel and serial geothermal preheating schemes and analyzes the thermodynamic performance of the hybrid geothermal–fossil power generation system for various geothermal resource temperatures. The models are used to analyze the effects of the temperature matching between the geothermal water and the feedwater, the heat losses and pumping power during the geothermal water transport and the resource distance and temperature on the power increase to improve the power generation. The serial geothermal preheating (SGP) scheme generally generates more additional power than the parallel geothermal preheating (PGP) scheme for geothermal resource temperatures of 100–130 °C, but the SGP scheme generates slightly less additional power than the PGP scheme when the feedwater is preheated to as high a temperature as possible before entering the deaerator for geothermal resource temperatures higher than 140 °C. The additional power decreases as the geothermal source distance increases since the pipeline pumping power increases and the geothermal water temperature decreases due to heat losses. More than 50% of the power decrease is due to geothermal

  13. Performance of Doubly-Fed Wind Power Generators During Voltage Dips

    DEFF Research Database (Denmark)

    Aparicio, N.; Chen, Zhe; Beltran, H.

    The growing of wind generation in Spain has forced its Transmission System Operator (TSO) to release new requirements that establish the amount of reactive power that a wind turbine has to supply to the grid during a voltage dip. Wind turbines equipped with doubly-fed induction generators (DFIG......) can regulate easily the reactive power generated in steady state. However, difficulties appear when reactive power has to be generated during voltage dips. Simulations have been carried out in order to check whether DFIG wind turbines can fulfill the reactive power requirements. Protection system...... commonly employed with DFIG in order to achieve ride-through capabilities including crowbar plays an important role to meet the requirements together with grid-side converter. Resistance associated with the crowbar and its connection duration are crucial at the beginning of the fault. Grid-side converter...

  14. Performance Investigation of Millimeter Wave Generation Reliant on Stimulated Brillouin Scattering

    Science.gov (United States)

    Tickoo, Sheetal; Gupta, Amit

    2018-04-01

    In this work, photonic method of generating the millimeter waves has been done based on Brillouin scattering effect in optical fiber. Here different approaches are proposed to get maximum frequency shift in mm-wave region using only pumps, radio signals with Mach-Zehnder modulator. Moreover for generated signal validation, signals modulated and send to both wired and wireless medium in optical domain. It is observed that maximum shift of 300 GHz is realized using 60 GHz input sine wave. Basically a frequency doubler is proposed which double shift of input frequency and provide better SNR. For the future generation network system, the generation of millimeter waves makes them well reliable for the transmission of the data.

  15. On the reliability of steam generator performance at nuclear power plants with WWER type reactors

    International Nuclear Information System (INIS)

    Styrikovich, M.A.; Margulova, T.Kh.

    1974-01-01

    The problem of ensuring reliable operation of steam generators in a nuclear power plant with a water-cooled, water-moderated reactor (WWER) was studied. At a nuclear power plant with a vertical steam generator (specifically, a Westinghouse product) the steam generator tubes were found to have been penetrated. Shutdown was due to corrosion disintegration of the austenitic stainless steel, type 18/8, used as pipe material for the heater surface. The corrosion was the result of the action of chlorine ions concentrated in the moisture contained in the iron oxide films deposited in low parts of the tube bundle, directly at the tube plate. Blowing through did not ensure complete removal of the film, and in some cases the construction features of the steam generator made removal of the film practically impossible. Replacement of type 18/8 stainless steel by other construction material, e.g., Inconel, did not give good results. To ensure reliable operation of vertical steam generators in domestic practice, the generators are designed without a low tube plate (a variant diagram of the vertical steam generator of such construction for the water-cooled, water-moderated reactor 1000 is presented). When low tube plates are used the film deposition is intolerable. For organization of a non-film regime a complex treatment of the feed water is used, in which the amount of complexion is calculated from the stoichmetric ratios with the composition of the feed water. It is noted that, if 100% condensate purification is used with complexon processing of the feed water to the generator, we can calculate the surface of the steam-generator heater without considering the outer placement on the tubes. In this the cost of the steam generator and all the nuclear power plants with WWER type reactors is decreased even with installation of a 100% condensate purification. It is concluded that only simultaneous solution of construction and water-regime problems will ensure relaible operation of

  16. Performance of Generating Plant: Managing the Changes. Part 3: Renewable energy plant: reports on wind, photovoltaics and biomas energies

    Energy Technology Data Exchange (ETDEWEB)

    Manoha, Bruno; Cohen, Martin [Electricite de France (France)

    2008-05-15

    The WEC Committee on the Performance of Generating Plant (PGP) has been collecting and analysing power plant performance statistics worldwide for more than 30 years and has produced regular reports, which include examples of advanced techniques and methods for improving power plant performance through benchmarking. A series of reports from the various working groups was issued in 2008. This reference presents the results of Working Group 3 (WG3). WG3 will promote the introduction of performance indicators for renewable energy generating plant (wind, geothermal, solar and biomass) developed by the Committee. It will also assess selected transitional technology issues and environmental factors related to non-conventional technologies. The WG3 report includes sections on Wind Energy Today, Photovoltaics Energy Today, Biomass Electricity Today and appendices.

  17. Robust and Low-Cost Flame-Treated Wood for High-Performance Solar Steam Generation.

    Science.gov (United States)

    Xue, Guobin; Liu, Kang; Chen, Qian; Yang, Peihua; Li, Jia; Ding, Tianpeng; Duan, Jiangjiang; Qi, Bei; Zhou, Jun

    2017-05-03

    Solar-enabled steam generation has attracted increasing interest in recent years because of its potential applications in power generation, desalination, and wastewater treatment, among others. Recent studies have reported many strategies for promoting the efficiency of steam generation by employing absorbers based on carbon materials or plasmonic metal nanoparticles with well-defined pores. In this work, we report that natural wood can be utilized as an ideal solar absorber after a simple flame treatment. With ultrahigh solar absorbance (∼99%), low thermal conductivity (0.33 W m -1 K -1 ), and good hydrophilicity, the flame-treated wood can localize the solar heating at the evaporation surface and enable a solar-thermal efficiency of ∼72% under a solar intensity of 1 kW m -2 , and it thus represents a renewable, scalable, low-cost, and robust material for solar steam applications.

  18. Coal-fired high performance power generating system. Quarterly progress report, July 1, 1993--September 30, 1993

    Energy Technology Data Exchange (ETDEWEB)

    1993-12-31

    This report covers work carried out under Task 3, Preliminary Research and Development, and Task 4, Commercial Generating Plant Design, under contract DE-AC22-92PC91155, {open_quotes}Engineering Development of a Coal Fired High Performance Power Generation System{close_quotes} between DOE Pittsburgh Energy Technology Center and United Technologies Research Center. The goals of the program are to develop a coal-fired high performance power generation system (HIPPS) by the year 2000 that is capable of >47% thermal efficiency; NO{sub x}, SO{sub x}, and particulates {le} 25% NSPS; cost {ge} 65% of heat input; and all solid wastes benign. The report discusses progress in cycle analysis, chemical reactor modeling, ash deposition rate calculations for HITAF (high temperature advanced furnace) convective air heater, air heater materials, and deposit initiation and growth on ceramic substrates.

  19. Status and integration of the gas generation studies performed for the Hydrogen Safety Program

    International Nuclear Information System (INIS)

    Pederson, L.R.; Strachan, D.M.

    1993-02-01

    Waste in Tank 241-SY-101 on the Hanford Site generates and periodically releases hydrogen, nitrous oxide, and nitrogen gases. Studies have been conducted at several laboratories to determine the chemical mechanisms for the gas generation and release. Results from these studies are presented and integrated in an attempt to describe current understanding of the physical properties of the waste and the mechanisms of gas generation and retention. Existing tank data are consistent with the interpretation that gases are uniformly generated in the tank, released continuously from the convecting layer, and stored in the nonconvecting layer. Tank temperature measurements suggest that the waste consists of ''gobs'' of material that reach neutral buoyancy at different times. The activation energy of the rate limiting step of the gas generating process was calculated to be about 7 kJ/mol but measured in the laboratory at 80 to 100 kJ/mol. Based on observed temperature changes in the tank the activation energy is probably not higher than about 20 kJ/mol. Several simulated waste compositions have been devised for use in laboratory studies in the place of actual waste from Tank 241-SY-101. Data from these studies can be used to predict how the actual waste might behave when heated or diluted. Density evaluations do not confirm that heating waste at the bottom of the tank would induce circulation within the waste; however, heating may release gas bubbles by dissolving the solids to which the bubbles adhere. Gas generation studies on simulated wastes indicated that nitrous oxide and hydrogen yields are not particularly coupled. Solubility studies of nitrous oxide, the most soluble of the principal gaseous products, indicate it is unlikely that dissolved gases contribute substantially to the quantity of gas released during periodic events

  20. Unseen disadvantage: how American universities' focus on independence undermines the academic performance of first-generation college students.

    Science.gov (United States)

    Stephens, Nicole M; Fryberg, Stephanie A; Markus, Hazel Rose; Johnson, Camille S; Covarrubias, Rebecca

    2012-06-01

    American universities increasingly admit first-generation college students whose parents do not have 4-year degrees. Once admitted, these students tend to struggle academically, compared with continuing-generation students--students who have at least 1 parent with a 4-year degree. We propose a cultural mismatch theory that identifies 1 important source of this social class achievement gap. Four studies test the hypothesis that first-generation students underperform because interdependent norms from their mostly working-class backgrounds constitute a mismatch with middle-class independent norms prevalent in universities. First, assessing university cultural norms, surveys of university administrators revealed that American universities focus primarily on norms of independence. Second, identifying the hypothesized cultural mismatch, a longitudinal survey revealed that universities' focus on independence does not match first-generation students' relatively interdependent motives for attending college and that this cultural mismatch is associated with lower grades. Finally, 2 experiments at both private and public universities created a match or mismatch for first-generation students and examined the performance consequences. Together these studies revealed that representing the university culture in terms of independence (i.e., paving one's own paths) rendered academic tasks difficult and, thereby, undermined first-generation students' performance. Conversely, representing the university culture in terms of interdependence (i.e., being part of a community) reduced this sense of difficulty and eliminated the performance gap without adverse consequences for continuing-generation students. These studies address the urgent need to recognize cultural obstacles that contribute to the social class achievement gap and to develop interventions to address them. 2012 APA, all rights reserved

  1. High-performance piezoelectric thick film based energy harvesting micro-generators for MEMS

    DEFF Research Database (Denmark)

    Zawada, Tomasz; Hansen, Karsten; Lou-Moeller, Rasmus

    2010-01-01

    and are transformed by the energy harvesting micro-generator into usable electrical signal. The micro-generator comprises a silicon cantilever with integrated InSensor® TF2100 PZT thick film deposited using screen-printing. The output power versus frequency and electrical load has been investigated. Furthermore......, devices based on modified, pressure treated thick film materials have been tested and compared with the commercial InSensor® TF2100 PZT thick films. It has been found that the structures based on the pressure treated materials exhibit superior properties in terms of energy output....

  2. Comparison and analysis of transient performances for doubly fed induction generator wind turbine under grid voltage dip

    DEFF Research Database (Denmark)

    Li, H.; Ye, R.; Han, L.

    2010-01-01

    In order to entirely analyze the transient performances of a grid-connected doubly fed induction generator (DFIG) wind turbine under the different operational states, based on the transient models of DFIG, a two-mass wind turbine electrical equivalent model considering the torsional flexibility o...

  3. Evaluation of the Performance of Vortex Generators on the DU 91-W2-250 Profile using Stereoscopic PIV

    DEFF Research Database (Denmark)

    Velte, Clara Marika; Hansen, Martin Otto Laver; Meyer, Knud Erik

    2009-01-01

    Stereoscopic PIV measurements investigating the effect of Vortex Generators on the lift force near stall and on glide ratio at best aerodynamic performance have been carried out in the LM Glasfiber wind tunnel on a DU 91-W2-250 profile. Measurements at two Reynolds numbers were analyzed; Re=0...

  4. Evaluation of the Performance of Vortex Generators on the DU 91-W2-250 Profile using Stereoscopic PIV

    DEFF Research Database (Denmark)

    Velte, Clara Marika; Hansen, Martin Otto Laver; Meyer, Knud Erik

    2008-01-01

    Stereoscopic PIV measurements investigating the effect of Vortex Generators on the lift force near stall and on glide ratio at best aerodynamic performance have been carried out in the LM Glasfiber wind tunnel on a DU 91-W2-250 profile. Measurements at two Reynolds numbers were analyzed; Re=0...

  5. Performance assessment of commercial relays for anti-islanding protection of rotating machine based distributed generation

    Energy Technology Data Exchange (ETDEWEB)

    Katiraei, F. [Quanta Technology, Houston, TX (United States); Abbey, C. [Natural Resources Canada, Ottawa, ON (Canada). CANMET Energy Technology Centre; Da Cunha, I. [LeapFrog Energy Technologies Inc., Mississauga, ON (Canada); Brisette, Y. [Hydro-Quebec, Montreal, PQ (Canada). Research Inst

    2008-07-01

    According to power industry standards, distributed generation must stop energizing the power grid upon loss of the main system. Either passive or active methods may be used to fulfill this requirement. Passive methods rely on locally measured signals to determine whether the main grid is present, while active methods inject a perturbation into the system that will manifest itself in locally measured signals if the main grid is not present. This paper compared simulation and experimental results for various commercially available relays for passive anti-islanding protection of small (below 500 kW) distributed generators using either synchronous or induction generators. A commercial multifunction relay and an application specific relay for rate-of-change-of-frequency and vector shift were modelled in simulation. Simulation results were compared with tests using a 25 kV induction generator. Results obtained for the induction machine based DG were in good agreement with trip times associated with under/overvoltage relays. The poor results with frequency based relays may be attributed to the method used for calculating frequency. Sensitivity analysis on the degree of capacitor compensation revealed a small non-detection zone, suggesting that this risk should be evaluated for induction machine based interconnections. These results showed that accurate relay modeling is challenging, particularly for frequency based techniques. Other methods for relay testing, such as hardware-in-the-loop, may be more appropriate than simulation, and are more practical in terms of cost effectiveness, than extensive field trials. 7 refs., 1 tab., 6 figs.

  6. Generation of (synthetic) influent data for performing wastewater treatment modelling studies

    DEFF Research Database (Denmark)

    Flores Alsina, Xavier; Ort, Christoph; Martin, Cristina

    2014-01-01

    resolution (from minutes to years). The importance of calibration/validation is addressed and the authors critically analyse the pros and cons of manual versus automatic and frequentistic vs Bayesian methods. The presentation will focus on potential engineering applications of influent generators...

  7. Current and future economic performance of first and second generation biofuels in developing countries

    NARCIS (Netherlands)

    van Eijck, Janske|info:eu-repo/dai/nl/297954296; Batidzirai, Batidzirai|info:eu-repo/dai/nl/341355909; Faaij, Andre

    2014-01-01

    Net Present Value (NPV) and total production cost calculations aremade for first and second generation biofuels in 74 settings, covering 5 fuel output types, 8 feedstock types, 12 countries and 8 combinations of agricultural management systems between 2010 and 2030. Yields are assumed to increase

  8. Dielectric barrier discharge plasma atomizer for hydride generation atomic absorption spectrometry-Performance evaluation for selenium

    Czech Academy of Sciences Publication Activity Database

    Duben, Ondřej; Boušek, J.; Dědina, Jiří; Kratzer, Jan

    2015-01-01

    Roč. 111, SEP (2015), s. 57-63 ISSN 0584-8547 Grant - others:GA AV ČR(CZ) M200311202 Institutional support: RVO:68081715 Keywords : dielectric barrier discharge * hydride generation-atomic absorption spectrometry * selenium Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.289, year: 2015

  9. Next Generation Anodes for Lithium-Ion Batteries: Thermodynamic Understanding and Abuse Performance

    Energy Technology Data Exchange (ETDEWEB)

    Fenton, Kyle R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Allcorn, Eric [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Nagasubramanian, Ganesan [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-12-01

    The objectives of this report are as follows: elucidate degradation mechanisms, decomposition products, and abuse response for next generation silicon based anodes; and Understand the contribution of various materials properties and cell build parameters towards thermal runaway enthalpies. Quantify the contributions from particle size, composition, state of charge (SOC), electrolyte to active materials ratio, etc.

  10. Next Generation Anodes for Lithium Ion Batteries: Thermodynamic Understanding and Abuse Performance.

    Energy Technology Data Exchange (ETDEWEB)

    Fenton, Kyle R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Allcorn, Eric [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Nagasubramanian, Ganesan [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-09-01

    The objectives of this project are to elucidate degradation mechanisms, decomposition products, and abuse response for next generation silicon based anodes; and understand the contribution of various materials properties and cell build parameters towards thermal runaway enthalpies. Quantify the contributions from various cell parameters such as particle size, composition, state of charge (SOC), electrolyte to active materials ratio, etc.

  11. Workplaces that Support High-Performing Teaching and Learning: Insights from Generation Y Teachers

    Science.gov (United States)

    Coggshall, Jane G.; Behrstock-Sherratt, Ellen; Drill, Karen

    2011-01-01

    Generation Y public school teachers--those born between 1977 and 1995-- who have been serving students for nearly a decade now, represent an increasingly large proportion of the teaching workforce, and, with concerted support, promise to help bring needed transformation to schools that too often remain stuck in an earlier age. Members of this…

  12. Generation of synthetic influent data to perform (micro)pollutant wastewater treatment modelling studies

    DEFF Research Database (Denmark)

    Snip, Laura; Flores Alsina, Xavier; Aymerich, I

    2016-01-01

    metabolites with samples taken every 2-4h: the anti-inflammatory drug ibuprofen (IBU), the antibiotic sulfamethoxazole (SMX) and the psychoactive carbamazepine (CMZ). Information about type of excretion and total consumption rates forms the basis for creating the data-defined profiles used to generate...

  13. Performance of diesel cycle engine-generator operating on dual fuel ...

    African Journals Online (AJOL)

    The Brazilian Federal Government aims to expand the electrical energy ... at the generator, leading to a power increase of 43.8% saving R$ 0.86 for each kW h-1. ... the diesel consumption to produce electricity in the isolated communities.

  14. Development and performance evaluation of an electromagnetic-type shock wave generator for lipolysis

    Energy Technology Data Exchange (ETDEWEB)

    Liang, S. M., E-mail: liangsm@cc.feu.edu.tw; Yang, Z. Y. [Department of Industrial Design, Far East University, No. 49, Zhonghua Road, Xinshi District, Tainan City 744, Taiwan (China); Chang, M. H. [Department of Aeronautics and Astronautics, National Cheng Kung University, No. 1, University Road, East District, Tainan City 701, Taiwan (China)

    2014-01-15

    This study aims at the design and development of electromagnetic-type intermittent shock wave generation in a liquid. The shock wave generated is focused at a focal point through an acoustic lens. This hardware device mainly consists of a full-wave bridge rectifier, 6 capacitors, a spark gap, and a flat coil. A metal disk is mounted in a liquid-filled tube and is placed in close proximity to the flat coil. Due to the repulsive force existing between the coil and disk shock waves are generated, while an eddy current is induced in the metal disk. Some components and materials associated with the device are also described. By increasing the capacitance content to enhance electric energy level, a highly focused pressure can be achieved at the focal point through an acoustic lens in order to lyse fat tissue. Focused pressures were measured at the focal point and its vicinity for different operation voltages. The designed shock wave generator with an energy intensity of 0.0016 mJ/mm{sup 2} (at 4 kV) and 2000 firings or higher energy intensities with 1000 firings is found to be able to disrupt pig fat tissue.

  15. Development and performance evaluation of an electromagnetic-type shock wave generator for lipolysis.

    Science.gov (United States)

    Liang, S M; Chang, M H; Yang, Z Y

    2014-01-01

    This study aims at the design and development of electromagnetic-type intermittent shock wave generation in a liquid. The shock wave generated is focused at a focal point through an acoustic lens. This hardware device mainly consists of a full-wave bridge rectifier, 6 capacitors, a spark gap, and a flat coil. A metal disk is mounted in a liquid-filled tube and is placed in close proximity to the flat coil. Due to the repulsive force existing between the coil and disk shock waves are generated, while an eddy current is induced in the metal disk. Some components and materials associated with the device are also described. By increasing the capacitance content to enhance electric energy level, a highly focused pressure can be achieved at the focal point through an acoustic lens in order to lyse fat tissue. Focused pressures were measured at the focal point and its vicinity for different operation voltages. The designed shock wave generator with an energy intensity of 0.0016 mJ/mm(2) (at 4 kV) and 2000 firings or higher energy intensities with 1000 firings is found to be able to disrupt pig fat tissue.

  16. Measurement framework for product service system performance of generator set distributors

    Science.gov (United States)

    Sofianti, Tanika D.

    2017-11-01

    Selling Generator Set (Genset) in B2B market, distributors assisted manufacturers to sell products. This is caused by the limited resources owned by the manufacturer for adding service elements. These service elements are needed to enhance the competitiveness of the generator sets. Some genset distributors often sell products together with supports to their customers. Industrial distributor develops services to meet the needs of the customer. Generator set distributors support machines and equipment produced by manufacturer. The services delivered by the distributors could enhance value obtained by the customers from the equipment. Services provided to customers in bidding process, ordering process of the equipment from the manufacturer, equipment delivery, installations, and the after sales stage. This paper promotes framework to measure Product Service System (PSS) of Generator Set distributors in delivering their products and services for the customers. The methodology of conducting this research is by adopting the perspective of the providers and customers and by taking into account the tangible and intangible products. This research leads to the idea of improvement of current Product Service System of a Genset distributor. This research needs further studies in more detailed measures and the implementation of measurement tools.

  17. Chemical vapour generation of silver: reduced palladium as permanent reaction modifier for enhanced performance

    Czech Academy of Sciences Publication Activity Database

    Matoušek, Tomáš; Sturgeon, R. E.

    2004-01-01

    Roč. 19, č. 8 (2004), s. 1014-1017 ISSN 0267-9477 R&D Projects: GA ČR GA203/01/0453 Institutional research plan: CEZ:AV0Z4031919 Keywords : chemical vapour generation * chemical modification * silver Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.926, year: 2004

  18. The maximum theoretical performance of unconcentrated solar photovoltaic and thermoelectric generator systems

    DEFF Research Database (Denmark)

    Bjørk, Rasmus; Nielsen, Kaspar Kirstein

    2017-01-01

    The maximum efficiency for photovoltaic (PV) and thermoelectric generator (TEG) systems without concentration is investigated. Both a combined system where the TEG is mounted directly on the back of the PV and a tandem system where the incoming sunlight is split, and the short wavelength radiation...

  19. Optimization of disk generator performance for base-load power plant systems applications

    International Nuclear Information System (INIS)

    Teare, J.D.; Loubsky, W.J.; Lytle, J.K.; Louis, J.F.

    1980-01-01

    Disk generators for use in base-load MHD power plants are examined for both open-cycle and closed-cycle operating modes. The OCD cases are compared with PSPEC results for a linear channel; enthalpy extractions up to 23% with 71% isentropic efficiency are achievable with generator inlet conditions similar to those used in PSPEC, thus confirming that the disk configuration is a viable alternative for base-load power generation. The evaluation of closed-cycle disks includes use of a simplified cycle model. High system efficiencies over a wide range of power levels are obtained for effective Hall coefficients in the range 2.3 to 4.9. Cases with higher turbulence (implying β/sub eff/ less than or equal to 2.4) yield high system efficiencies at power levels of 100 to 500 MW/sub e/. All these CCD cases compare favorably with linear channels reported in the GE ECAS study, yielding higher isentropic efficiences for a given enthalpy extraction. Power densities in the range 70 to 170 MW/m 3 appear feasible, leading to very compact generator configurations

  20. Performance analysis of an absorption double-effect cycle for power and cold generation using ammonia/lithium nitrate

    International Nuclear Information System (INIS)

    Ventas, R.; Lecuona, A.; Vereda, C.; Rodriguez-Hidalgo, M.C.

    2017-01-01

    Highlights: • Two-stage double-effect cycle for combined power and cooling with flexibility. • Ammonia/lithium nitrate as solution for the absorption cycle. • Efficiency, when only producing power, of 19.5% for a generation temperature of 173 °C. • When combined cooling and power COP = 0.53 and electric efficiency of 5% for a generation temperature of 140 °C. • Better efficiencies than conventional double-effect cycles. - Abstract: The performance of a two-stage double-effect absorption machine for combined power and cold generation is proposed and studied theoretically, generating innovative schemes. The ammonia/lithium nitrate solution allows this cycle, consuming either solar thermal or residual heat. The machine is represented by means of a thermodynamic steady-state cycle. First, only power generation and only cold production are separately studied as function of the main internal temperatures, introducing the concepts of mixed and unmixed vapour and of virtual temperatures for allowing comparison. The results indicate that for producing power the efficiency of the cycle increases when rising the maximum pressure while for producing cold is the contrary. The maximum efficiency obtained for only power production with no superheating is 19.5% at a high generation temperature of 173 °C and at a moderate 20.3 bars of maximum pressure. The solution crystallization avoids a higher efficiency. The combined power and cooling cycle allows adapting the energy production to cold demand or to power demand by splitting the vapour generated. At a generation temperature of 132 °C, when splitting the vapour generated into half for power and half for cooling, the cycle obtains an electric efficiency of 6.5% and a COP of 0.52. This cycle is compared to a conventional double-effect cycle configured in parallel flow, obtaining the same electric efficiency but with a 32% higher COP.

  1. Air-stable hydrogen generation materials and enhanced hydrolysis performance of MgH2-LiNH2 composites

    Science.gov (United States)

    Ma, Miaolian; Ouyang, Liuzhang; Liu, Jiangwen; Wang, Hui; Shao, Huaiyu; Zhu, Min

    2017-08-01

    Hydrolysis of materials in water can be a promising solution of onsite hydrogen generation for realization of hydrogen economy. In this work, it was the first time that the MgH2-LiNH2 composites were explored as air-stable hydrolysis system for hydrogen generation. The MgH2-LiNH2 composites with different composition ratios were synthesized by ball milling with various durations and the hydrogen generation performances of the composite samples were investigated and compared. X-ray diffraction, X-ray photoelectron spectroscopy and scanning electron microscopy techniques were adopted to elucidate the performance improvement mechanisms. The hydrolysis properties of MgH2 were found to be significantly enhanced by the introduction of LiNH2. The 4MgH2-LiNH2 composite ball milled for 5 h can generate 887.2 mL g-1 hydrogen in 1 min and 1016 mL g-1 in 50 min, one of the best results so far for Mg based hydrolysis materials. The LiOH·H2O and NH4OH phases of hydrolysis products from LiNH2 may prevent formation of Mg(OH)2 passivation layer on the surface and supply enough channels for hydrolysis of MgH2. The MgH2-LiNH2 composites appeared to be very stable in air and no obvious negative effect on kinetics and hydrogen generation yield was observed. These good performances demonstrate that the studied MgH2-LiNH2 composites can be a promising and practicable hydrogen generation system.

  2. Evaluation of the Effect of Operating Parameters on Thermal Performance of an Integrated Starter Generator in Hybrid Electric Vehicles

    Directory of Open Access Journals (Sweden)

    Moo-Yeon Lee

    2015-08-01

    Full Text Available The belt-driven-type integrated starter generator motor in a hybrid electric vehicle is vulnerable to thermal problems owing to its high output power and proximity to the engine. These problems may cause demagnetization and insulation breakdown, reducing the performance and durability of the motor. Hence, it is necessary to evaluate the thermal performance and enhance the cooling capacity of the belt-driven type Integrated Starter Generator. In this study, the internal temperature variations of the motor were investigated with respect to the operating parameters, particularly the rotation speed and environment temperature. At a maximum ambient temperature of 105 °C and rotation speed (motor design point of 4500 rpm, the coil of the motor was heated to approximately 189 °C in generating mode. The harsh conditions of the starting mode were analyzed by assuming that the motor operates during the start-up time at a maximum ambient temperature of 105 °C and rotation speed (motor design point of 800 rpm; the coil was heated to approximately 200 °C, which is close to the insulation temperature limit. The model for analyzing the thermal performance of the ISG was verified by comparing its results with those obtained through a generating-mode-based experiment

  3. Design and performance of a Tesla transformer type relativistic electron beam generator

    International Nuclear Information System (INIS)

    Jain, K.K.; Chennareddy, D.; John, P.I.; Saxena, Y.C.

    1986-01-01

    A relativistic electron beam generator driven by an air core Tesla transformer is described. The Tesla transformer circuit analysis is outlined and computational results are presented for the case when the coaxial water line has finite resistance. The transformer has a coupling coefficient of 0.56 and a step-up ratio of 25. The Tesla transformer can provide 800 kV at the peak of the second half cycle of the secondary output voltage and has been tested up to 600 kV. A 100-200 keV, 15-20 kA electron beam having 150 ns pulse width has been obtained. The beam generator described is being used for the beam injection into a toroidal device BETA. (author). 20 refs. 9 figures

  4. An artificial generation of a few specific wave conditions: New simulator design and experimental performance

    International Nuclear Information System (INIS)

    Ramadan, A.; Mohamed, M.H.; Marzok, S.Y.; Montasser, O.A.; El Feky, A.; El Baz, A.R.

    2014-01-01

    In recent years, an amplified global awareness has led to a reawakening of interest in renewable energy technology. In an effort to reduce the worldwide dependence on fossil fuels, cleaner power generation methods are being sought in the field of solar, biomass, wind and wave energy. The importance of wave energy is increased in particular in some countries like UK, Portugal, Spain and Japan. A considerable progress has already been achieved in this field but the available technical designs are not adequate to develop reliable wave energy converters. Wave energy is the most available energy associated in water seas and oceans. Simultaneously, the wave energy has consisted of two types of energies: potential and kinetic energy. Therefore, many attempts have been applied to capture these energies. In the present work, a wave generator device has been designed and manufactured to simulate and generate the heaving motion of sea waves with different specification. A PC based electro-pneumatic control system was designed and implemented to individually control wave height, these heights are 3, 8, 16, 18 and 20 cm and different frequencies to generate these regular and irregular waves. - Highlights: • Wave energy is one of the most promising sources of renewable energy. • Most researchers built huge flume to simulate waves with large size and high budget. • A new simulator design for the direct and indirect wave energy is introduced. • The regular and irregular wave can be obtained for the new wave simulator. • This design is compact, flexible in terms amplitude, frequencies and high accuracy

  5. Graphene sheets/cobalt nanocomposites as low-cost/high-performance catalysts for hydrogen generation

    International Nuclear Information System (INIS)

    Zhang, Fei; Hou, Chengyi; Zhang, Qinghong; Wang, Hongzhi; Li, Yaogang

    2012-01-01

    The production of clean and renewable hydrogen through the hydrolysis of sodium borohydride has received much attention owing to increasing global energy demands. Graphene sheets/cobalt (GRs/Co) nanocomposites, which are highly efficient catalysts, have been prepared using a one-step solvothermal method in ethylene glycol. Co 2+ salts were converted to Co nanoparticles, which were simultaneously inserted into the graphene layers with the reduction of graphite oxide sheets to GRs. The as-synthesized samples were characterized by X-ray diffraction, Fourier transform infrared spectra, Raman spectroscopy, field emission scanning electron microscopy, transmission electron microscopy, high-resolution transmission electron microscopy and vibrating sample magnetometer. The maximum saturation magnetization value reached 80.8 emu g −1 , meaning they are more suitable for magnet-controlled generation of H 2 than noble metal catalysts. The catalytic activity of the composite was investigated by the hydrolysis of sodium borohydride in aqueous solution both with and without a GRs support. It was found that the high electronic conductive GRs support increased the hydrogen generation rate (about two times) compared with pure cobalt. The improved hydrogen generation rate, low cost and uncomplicated recycling makes the GRs/Co nanocomposites promising candidates as catalysts for hydrogen generation. Highlights: ► Graphene sheets/cobalt nanocomposites were prepared by a one-step solvothermal method. ► The maximum saturation magnetization value of the composites reached 80.8 emu g −1 . ► The graphene support greatly increased the catalytic activity of cobalt. ► An easily removed, recycled and controlled functional filter was obtained.

  6. Improving customer generation by increasing website performance and integrating IT systems

    OpenAIRE

    Ramlall, Shalini; Sanders, David; Powell, Henry; Ndzi, David

    2008-01-01

    This paper describes the research into the design of commercial websites. The research will lead to the identification of design elements that may have significant impact on user behaviour. The research will also investigate how these elements could be altered to provide a better browsing experience to users and ultimately increase online conversion and profit. The research focuses on the design of commercial websites. Their goal is to generate sales by selling products and services online or...

  7. The impact of user-generated content on Facebook advertising performance

    OpenAIRE

    Campos, Francisco de Bivar Velho da Costa

    2016-01-01

    Social media have strengthened the role of each consumer who have now multiple ways to create content, through product reviews, and rates, for instance. These contents, also known as user-generated content (UGC) have become one of the most important communication channels about brands, since, through it, peers can greatly influence other consumers in their purchase decisions. Particularly on social networks, namely on Facebook, UGC, which may take the form of post likes, post comments, sha...

  8. 1x2M steel performance in the BOR-60 steam generator

    International Nuclear Information System (INIS)

    Golovanov, V.N.; Shamardin, V.K.; Kondratiev, V.I.; Kryukov, F.N.; Chernobrovkin, Yu.V.; Bulanova, T.M.; Bai, V.F.

    The results from studies of 1x2M steel characteristics are presented. This steel was used as the material for the BOR-60 steam generator that had been in operation under the steam generating mode for 18,000 hs (35,000 hs in sodium). It was revealed that the pit corrosion depth on the water/steam side evaporative tube surfaces was about 0.25 μm and less and the total corrosion rate was less than 0.06 mm/y. The mechanical properties of the material were essentially similar both in the evaporator and superheater and met all the requirements imposed on. Based on the analysis of data on the decarbonizaton depth in sodium and on the corrosion damage in water and steam it was concluded that 1x2M steel can be successfully used as the steam generator material at the operating temperatures up to 470 deg. C and had sufficiently longer service-life as compared to 18,000 hs. (author)

  9. Concurrent word generation and motor performance: further evidence for language-motor interaction.

    Directory of Open Access Journals (Sweden)

    Amy D Rodriguez

    Full Text Available Embodied/modality-specific theories of semantic memory propose that sensorimotor representations play an important role in perception and action. A large body of evidence supports the notion that concepts involving human motor action (i.e., semantic-motor representations are processed in both language and motor regions of the brain. However, most studies have focused on perceptual tasks, leaving unanswered questions about language-motor interaction during production tasks. Thus, we investigated the effects of shared semantic-motor representations on concurrent language and motor production tasks in healthy young adults, manipulating the semantic task (motor-related vs. nonmotor-related words and the motor task (i.e., standing still and finger-tapping. In Experiment 1 (n = 20, we demonstrated that motor-related word generation was sufficient to affect postural control. In Experiment 2 (n = 40, we demonstrated that motor-related word generation was sufficient to facilitate word generation and finger tapping. We conclude that engaging semantic-motor representations can have a reciprocal influence on motor and language production. Our study provides additional support for functional language-motor interaction, as well as embodied/modality-specific theories.

  10. Performance of GUNGEN Idea Generation Support Groupware: Lessons from Over A Few Hundred Trial Sessions

    Science.gov (United States)

    Yuizono, Takaya; Munemori, Jun

    GUNGEN-DXII, a new version of the GUNGEN groupware, allows the users to process hundreds of qualitative data segments (phrases and sentences) and compose a coherent piece of text containing a number of emergent ideas. The idea generation process is guided by the KJ method, a leading idea generation technique in Japan. This paper describes functions of GUNGEN supporting three major sub-activities of idea generation, namely, brainstorming, idea clustering, and text composition, and also summarizes the results obtained from a few hundred trial sessions with the old and new GUNGEN systems in terms of some qualitative and quantitative measures. The results show that the sessions with GUNGEN yield intermediate and final products at least as good as those from the original paper-and-pencil KJ method sessions, in addition to the advantages of the online system, such as distance collaboration and digital storage of the products. Moreover, results from the new GUNGEN-DXII raises hope for enabling the users to handle an extremely large number of qualitative data segments in the near future.

  11. Dynamic performance investigation of once-through-type steam generator for NPP using a large-scale model

    International Nuclear Information System (INIS)

    Kats, F.M.; Ostrovskij, L.A.; Ehskin, N.B.

    1985-01-01

    An experimental bench is described as well as the results of dynamic performance investigation of mass- and heat transfer of the once-through type steam generator for the NPP with weak superheat. Coolant for the primary and secondary circuit is water. Under investigation conditions the possibility of changin.o primary and secondary circuit temperatures has been supphed as well as the primary circuit flow rate and the secondary circuit pressure changes. Transients for differen.t operating conditions are considered. The possibility for construction of the steam generator automatic control system is based

  12. Simulated Performance Evaluation of a Selective Tracker Through Random Scenario Generation

    DEFF Research Database (Denmark)

    Hussain, Dil Muhammad Akbar

    2006-01-01

    performance assessment. Therefore, a random target motion scenario is adopted. Its implementation in particular for testing the proposed selective track splitting algorithm using Kalman filters is investigated through a number of performance parameters which gives the activity profile of the tracking scenario......  The paper presents a simulation study on the performance of a target tracker using selective track splitting filter algorithm through a random scenario implemented on a digital signal processor.  In a typical track splitting filter all the observation which fall inside a likelihood ellipse...... are used for update, however, in our proposed selective track splitting filter less number of observations are used for track update.  Much of the previous performance work [1] has been done on specific (deterministic) scenarios. One of the reasons for considering the specific scenarios, which were...

  13. Performance and load data from Mod-0A and Mod-1 wind turbine generators

    Science.gov (United States)

    Spera, D. A.; Janetzke, D. C.

    1982-01-01

    Experimental data, together with supporting analysis, are presented on the power conversion performance and blade loading of large, horizontal-axis wind turbines tested at electric utility sites in the U.S. Four turbine rotor configurations, from 28 to 61 meters in diameter, and data from five test sites are included. Performance data are presented in the form of graphs of power and system efficiency versus free-stream wind speed. Deviations from theoretical performance are analyzed statistically. Power conversion efficiency averaged 0.34 for all tests combined, compared with 0.31 predicted. Round blade tips appeared to improve performance significantly. Cyclic blade loads were normalized to develop load factors which can be used in the design of rotors with rigid hubs.

  14. Major heat exchanger performance in Ontario Hydro-operated CANDU nuclear generating stations

    International Nuclear Information System (INIS)

    Dueck, D.G.

    1980-01-01

    The performance of heat exchangers is described in terms of their impact on the unit in the form of forced outages and deratings as well as incapability due to scheduled outages. Some major problems with heat exchangers are highlighted. (auth)

  15. A High Performance Backend for Array-Oriented Programming on Next-Generation Processing Units

    DEFF Research Database (Denmark)

    Lund, Simon Andreas Frimann

    The financial crisis, which started in 2008, spawned the HIPERFIT research center as a preventive measure against future financial crises. The goal of prevention is to be met by improving mathematical models for finance, the verifiable description of them in domain-specific languages...... and the efficient execution of them on high performance systems. This work investigates the requirements for, and the implementation of, a high performance backend supporting these goals. This involves an outline of the hardware available today, in the near future and how to program it for high performance....... The main challenge is to bridge the gaps between performance, productivity and portability. A declarative high-level array-oriented programming model is explored to achieve this goal and a backend implemented to support it. Different strategies to the backend design and application of optimizations...

  16. Monitoring of the energy performance of a district heating CHP plant based on biomass boiler and ORC generator

    International Nuclear Information System (INIS)

    Prando, Dario; Renzi, Massimiliano; Gasparella, Andrea; Baratieri, Marco

    2015-01-01

    More than seventy district heating (DH) plants based on biomass are operating in South Tyrol (Italy) and most of them supply heat to residential districts. Almost 20% of them are cogenerative systems, thus enabling primary energy savings with respect to the separate production of heat and power. However, the actual performance of these systems in real operation can considerably differ from the nominal one. The main objectives of this work are the assessment of the energy performance of a biomass boiler coupled with an Organic Rankine Cycle (i.e. ORC) generator under real operating conditions and the identification of its potential improvements. The fluxes of energy and mass of the plant have been measured onsite. This experimental evaluation has been supplemented with a thermodynamic model of the ORC generator, calibrated with the experimental data, which is capable to predict the system performance under different management strategies of the system. The results have highlighted that a decrease of the DH network temperature of 10 °C can improve the electric efficiency of the ORC generator of one percentage point. Moreover, a DH temperature reduction could decrease the main losses of the boiler, namely the exhaust latent thermal loss and the exhaust sensible thermal loss, which account for 9% and 16% of the boiler input power, respectively. The analysis of the plant has pointed out that the ORC pump, the flue gases extractor, the thermal oil pump and the condensation section fan are the main responsible of the electric self-consumption. Finally, the negative effect of the subsidisation on the performance of the plant has been discussed. - Highlights: • Energy performance of a biomass boiler coupled to an ORC turbine in real operation. • Potential improvements of a CHP plant connected to a DH network. • Performance prediction by means of a calibrated ORC thermodynamic model. • Influence of the DH temperature on the electric efficiency. • Impact of the

  17. Drop performance test of conceptually designed control rod assembly for prototype generation IV sodium-cooled fast reactor

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young Kyu; Lee, Jae Han; Kim, Hoe Woong; KIm, Sung Kyun; Kim, Jong Bum [Sodium-cooled Fast Reactor NSSS Design Division, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2017-06-15

    The control rod assembly controls reactor power by adjusting its position during normal operation and shuts down chain reactions by its free drop under scram conditions. Therefore, the drop performance of the control rod assembly is important for the safety of a nuclear reactor. In this study, the drop performance of the conceptually designed control rod assembly for the prototype generation IV sodium-cooled fast reactor that is being developed at the Korea Atomic Energy Research Institute as a next-generation nuclear reactor was experimentally investigated. For the performance test, the test facility and test procedure were established first, and several free drop performance tests of the control rod assembly under different flow rate conditions were then carried out. Moreover, performance tests under several types and magnitudes of seismic loading conditions were also conducted to investigate the effects of seismic loading on the drop performance of the control rod assembly. The drop time of the conceptually designed control rod assembly for 0% of the tentatively designed flow rate was measured to be 1.527 seconds, and this agrees well with the analytically calculated drop time. It was also observed that the effect of seismic loading on the drop time was not significant.

  18. Development and testing of high performance pseudo random number generator for Monte Carlo simulation

    International Nuclear Information System (INIS)

    Chakraborty, Brahmananda

    2009-01-01

    Random number plays an important role in any Monte Carlo simulation. The accuracy of the results depends on the quality of the sequence of random numbers employed in the simulation. These include randomness of the random numbers, uniformity of their distribution, absence of correlation and long period. In a typical Monte Carlo simulation of particle transport in a nuclear reactor core, the history of a particle from its birth in a fission event until its death by an absorption or leakage event is tracked. The geometry of the core and the surrounding materials are exactly modeled in the simulation. To track a neutron history one needs random numbers for determining inter collision distance, nature of the collision, the direction of the scattered neutron etc. Neutrons are tracked in batches. In one batch approximately 2000-5000 neutrons are tracked. The statistical accuracy of the results of the simulation depends on the total number of particles (number of particles in one batch multiplied by the number of batches) tracked. The number of histories to be generated is usually large for a typical radiation transport problem. To track a very large number of histories one needs to generate a long sequence of independent random numbers. In other words the cycle length of the random number generator (RNG) should be more than the total number of random numbers required for simulating the given transport problem. The number of bits of the machine generally limits the cycle length. For a binary machine of p bits the maximum cycle length is 2 p . To achieve higher cycle length in the same machine one has to use either register arithmetic or bit manipulation technique

  19. Electrical performance analysis and economic evaluation of combined biomass cook stove thermoelectric (BITE) generator.

    Science.gov (United States)

    Lertsatitthanakorn, C

    2007-05-01

    The use of biomass cook stoves is widespread in the domestic sector of developing countries, but the stoves are not efficient. To advance the versatility of the cook stove, we investigated the feasibility of adding a commercial thermoelectric (TE) module made of bismuth-telluride based materials to the stove's side wall, thereby creating a thermoelectric generator system that utilizes a proportion of the stove's waste heat. The system, a biomass cook stove thermoelectric generator (BITE), consists of a commercial TE module (Taihuaxing model TEP1-1264-3.4), a metal sheet wall which acts as one side of the stove's structure and serves as the hot side of the TE module, and a rectangular fin heat sink at the cold side of the TE module. An experimental set-up was built to evaluate the conversion efficiency at various temperature ranges. The experimental set-up revealed that the electrical power output and the conversion efficiency depended on the temperature difference between the cold and hot sides of the TE module. At a temperature difference of approximately 150 degrees C, the unit achieved a power output of 2.4W. The conversion efficiency of 3.2% was enough to drive a low power incandescent light bulb or a small portable radio. A theoretical model approximated the power output at low temperature ranges. An economic analysis indicated that the payback period tends to be very short when compared with the cost of the same power supplied by batteries. Therefore, the generator design formulated here could be used in the domestic sector. The system is not intended to compete with primary power sources but serves adequately as an emergency or backup source of power.

  20. A New Second-Order Generalized Integrator Based Quadrature Signal Generator With Enhanced Performance

    DEFF Research Database (Denmark)

    Xin, Zhen; Qin, Zian; Lu, Minghui

    2016-01-01

    Due to the simplicity and flexibility of the structure of the Second-Order Generalized Integrator based Quadrature Signal Generator (SOGI-QSG), it has been widely used over the past decade for many applications such as frequency estimation, grid synchronization, and harmonic extraction. However......, the SOGI-QSG will produce errors when its input signal contains a dc component or harmonic components with unknown frequencies. The accuracy of the signal detection methods using it may hence be compromised. To overcome the drawback, the First-Order System (FOS) concept is first used to illustrate...

  1. Performance of a tagged neutron inspection system (TNIS) based on portable sealed generators

    International Nuclear Information System (INIS)

    Nebbia, G.; Pesente, S.; Lunardon, M.; Viesti, G.; LeTourneur, P.; Heuveline, F.; Mangeard, M.; Tcheng, C.

    2004-01-01

    A portable sealed neutron generator has been modified to produce 14MeV tagged neutron beams with an embedded YAP:Ce scintillation detector. The system has been tested by detecting the coincident gamma-rays produced in the irradiation of a graphite sample by means of a standard NaI(Tl) scintillator. Time resolution of about δt=4-5ns (FWHM) has been measured. The sealed neutron tube has been operated up to 10 7 neutron/s. Possible applications in non-destructive assays and future developments of the Tagged Neutron Inspection System concept are discussed

  2. Influence of external-detonation-generated plasmas on the performance of semi-confined explosive charges

    Energy Technology Data Exchange (ETDEWEB)

    Udy, L.L.

    1979-02-01

    External-detonation-generated plasmas, highly ionized zones of reacting material ejected from the surface of detonating explosive charges, are shown to be the cause of channel desensitization, i.e., the self-quenching of a detonating explosive column loaded in a borehole with an air annulus between the explosive and the borehole wall. The effects of this phenomenon on several explosive compositions and types are demonstrated and discussed. The explosives tested include aluminum-sensitized and explosive-sensitized slurries, ANFO, liquid explosives and dynamites. Various techniques are described that can be used to reduce or eliminate the plasma effect.

  3. Performance of Tc-99m generator prepared with Mo adsorbent PZC and irradiated nature MoO3

    International Nuclear Information System (INIS)

    Liu Yishu

    2006-01-01

    This paper describes the technical process of Tc-99m generator prepared with reactor actived Mo-99 and PZC and the performance of the generator was also reported. Two generators were prepared with different batch of PZC and by different technical process. The results show that the adsorption rate was ∼65% and the adsorption efficiency of 99 Mo can be seriously affected by the adsorption process (the temperature, intensity and frequency of shaking and the PZC volume in solution etc.). The elution efficiency was 43-73%. The Mo breakthrough 1.2 - 16% without safe column and its can be decreased to be very low by connecting a hydrate zirconia (HZO) safe column. (author)

  4. Prediction and analysis of the seasonal performance of tri-generation and CO2 refrigeration systems in supermarkets

    International Nuclear Information System (INIS)

    Ge, Y.T.; Tassou, S.A.; Suamir, I.N.

    2013-01-01

    Highlights: ► Integration model of a trigeneration with CO 2 refrigeration systems in supermarket. ► Validation of the developed integration model with site and laboratory measurement. ► Application of the trigeneration system in power generation and space conditioning. ► Performance analysis and comparison of the integrated system in supermarket. - Abstract: A modern supermarket energy control system has a concurrent need for electricity, space heating or cooling, and food refrigeration. The power supply to the supermarket is primarily from the national grid, where losses in efficiency are due to the processes of energy conversion and transmission. Combined heat and power (CHP) offers the potential to locally produce electrical power and heating which could save energy and reduce CO 2 emissions in the long run. During the summer months, as the space heating requirement in a supermarket is relatively small, the energy efficiency of a CHP installation can be improved by using excess thermal energy to drive a sorption refrigeration system to provide space cooling or refrigeration. This process is also known as tri-generation. In recent years, the use of CO 2 as a refrigerant in supermarkets has received considerable attention due to its negligible contribution to direct greenhouse gas emissions and excellent thermophysical and heat transfer properties. Consequently, the application of a tri-generation system in a supermarket with CO 2 refrigeration merits further investigation. In this paper, to evaluate the performance of a tri-generation system in the supermarket, a previously tested 80 kWe microturbine device was applied into an operational supermarket to generate power and provide space heating and cooling through exhaust heat. The performance evaluation and comparison for this tri-generation application is based on the prediction from an integrated model of supermarket energy control, cascade CO 2 refrigeration and tri-generation systems. The results

  5. Simulating the dust effect on the energy performance of photovoltaic generators based on experimental measurements

    International Nuclear Information System (INIS)

    Kaldellis, J.K.; Kapsali, M.

    2011-01-01

    One of the least analyzed side effects of atmospheric air pollution is the degradation of PV-panels' performance due to the deposition of solid particles varying in composition, size and type. In the current study, the experimental data concerning the effect of three representative air pollutants (i.e. red soil, limestone and carbonaceous fly-ash particles) on the energy performance of PV installations are analyzed. According to the results obtained, a considerable reduction of PVs' energy performance is recorded, depending strongly on particles' composition and source. Subsequently, a theoretical model has been developed in order to be used as an analytical tool for obtaining reliable results concerning the expected effect of regional air pollution on PVs' performance. Furthermore, experimental results concerning the dust effect on PVs' energy yield in an aggravated - from air pollution - urban environment are used to validate the proposed theoretical model. -- Highlights: → The effect of dust deposition on PVs energy efficiency is experimentally examined. → Based on the results, a considerable reduction of PVs energy performance is recorded. → The effect strongly depends on the dust composition and on the type of the pollutant. → A theoretical model is developed for predicting the dust deposition effect on PVs energy yield. → The model is validated on the basis of experiments conducted in urban environment.

  6. UMAMI: A Recipe for Generating Meaningful Metrics through Holistic I/O Performance Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Lockwood, Glenn K. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Yoo, Wucherl [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Byna, Suren [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Wright, Nicholas J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Snyder, Shane [Argonne National Lab. (ANL), Argonne, IL (United States); Harms, Kevin [Argonne National Lab. (ANL), Argonne, IL (United States); Nault, Zachary [Argonne National Lab. (ANL), Argonne, IL (United States); Carns, Philip [Argonne National Lab. (ANL), Argonne, IL (United States)

    2017-11-12

    I/O efficiency is essential to productivity in scientific computing, especially as many scientific domains become more data-intensive. Many characterization tools have been used to elucidate specific aspects of parallel I/O performance, but analyzing components of complex I/O subsystems in isolation fails to provide insight into critical questions: how do the I/O components interact, what are reasonable expectations for application performance, and what are the underlying causes of I/O performance problems? To address these questions while capitalizing on existing component-level characterization tools, we propose an approach that combines on-demand, modular synthesis of I/O characterization data into a unified monitoring and metrics interface (UMAMI) to provide a normalized, holistic view of I/O behavior. We evaluate the feasibility of this approach by applying it to a month-long benchmarking study on two distinct largescale computing platforms. We present three case studies that highlight the importance of analyzing application I/O performance in context with both contemporaneous and historical component metrics, and we provide new insights into the factors affecting I/O performance. By demonstrating the generality of our approach, we lay the groundwork for a production-grade framework for holistic I/O analysis.

  7. Modelling oil-shale integrated tri-generator behaviour: predicted performance and financial assessment

    International Nuclear Information System (INIS)

    Jaber, J.O.; Probert, S.D.; Williams, P.T.

    1998-01-01

    A simple theoretical model relating the inputs and outputs of the proposed process has been developed; the main objectives being to predict the final products (i.e. the production rates for liquid and gaseous fuels as well as electricity), the total energy-conversion efficiency and the incurred costs under various operating conditions. The tri-production concept involves the use of a circulating fluidised-bed combustor together with a gasifier, retort and simple combined-cycle plant. The mathematical model requires mass and energy balances to be undertaken: these are based on the scarce published data about retorting as well as fluidised-bed combustion and gasification of oil shale. A prima facie case is made that the proposed tri-production plant provides an attractive and economic means for producing synthetic fuels and electricity from oil shale. The unit cost of electricity, so generated, would at present be about 0.057 US$ per kWh, assuming a 10% annual interest charge on the invested capital. If the produced shale oil could be sold for more than 25 US$ per barrel, then the cost of the generated electricity would be appropriately less and hence more competitive. (author)

  8. Modelling oil-shale integrated tri-generator behaviour: predicted performance and financial assessment

    Energy Technology Data Exchange (ETDEWEB)

    Jaber, J.O.; Probert, S.D. [Cranfield University, Bedford (United Kingdom). School of Mechanical Engineering; Williams, P.T. [Leeds University (United Kingdom). Dept. of Fuel and Energy

    1998-02-01

    A simple theoretical model relating the inputs and outputs of the proposed process has been developed; the main objectives being to predict the final products (i.e. the production rates for liquid and gaseous fuels as well as electricity), the total energy-conversion efficiency and the incurred costs under various operating conditions. The tri-production concept involves the use of a circulating fluidised-bed combustor together with a gasifier, retort and simple combined-cycle plant. The mathematical model requires mass and energy balances to be undertaken: these are based on the scarce published data about retorting as well as fluidised-bed combustion and gasification of oil shale. A prima facie case is made that the proposed tri-production plant provides an attractive and economic means for producing synthetic fuels and electricity from oil shale. The unit cost of electricity, so generated, would at present be about 0.057 US$ per kWh, assuming a 10% annual interest charge on the invested capital. If the produced shale oil could be sold for more than 25 US$ per barrel, then the cost of the generated electricity would be appropriately less and hence more competitive. (author)

  9. Modelling oil-shale integrated tri-generator behaviour: predicted performance and financial assessment

    Energy Technology Data Exchange (ETDEWEB)

    Jaber, J.O.; Probert, S.D. [Cranfield University, Bedford (United Kingdom). School of Mechanical Engineering; Williams, P.T. [Leeds University (United Kingdom). Dept. of Fuel and Energy

    1998-03-01

    A simple theoretical model relating the inputs and outputs of the proposed process has been developed; the main objectives being to predict the final products (i.e., the production rates for liquid and gaseous fuels as well as electricity), the total energy-conversion efficiency and the incurred costs under various operating conditions. The tri-production concept involves the use of a circulating fluidised-bed combustor together with a gasifier, retort and simple combined-cycle plant. The mathematical model requires mass and energy balances to be undertaken: these are based on the scarce published data about retorting as well as fluidised-bed combustion and gasification of oilshale. A prima facie case is made that the proposed tri-production plant provides an attractive and economic means for producing synthetic fuels and electricity from oil shale. The unit cost of electricity, so generated, would at present be about 0.057 US$ per kWh, assuming a 10% annual interest charge on the invested capital. If the produced shale oil could be sold for more than 25 US$ per barrel, then the cost of the generated electricity would be appropriately less and hence more competitive. (author)

  10. Anxious Affinities: How Theatrical Performance Can Generate a Platform for Interpersonal Dialogue

    Directory of Open Access Journals (Sweden)

    Motal Jan

    2017-09-01

    Full Text Available The article combines both philosophical and psychological approaches to argue that art and theatre performance especially can be grasped as a revelation of the universal and basic human concern, which is existential anxiety. The author presents an opinion, that via performative acts on stage, spectators and performers/actors are interconnected in hermeneutic situation (Hans-Georg Gadamer, in which they play their existential experience. Therefore, the universal death anxiety (Irvin D. Yalom can be understood as a possible platform for interpersonal and intercultural dialogue (Martin Buber. The article concludes, that archetypes (Carl Gustav Jung are such a place for mutual understanding, representing both mental and physical answers to the basic existential experience of humankind.

  11. Performance analysis of a gas turbine for power generation using syngas as a fuel

    International Nuclear Information System (INIS)

    Lee, Jong Jun; Cha Kyu Sang; Kim, Tong Seop; Sohn, Jeong Lak; Joo, Yong Jin

    2008-01-01

    Integrated Gasification Combined Cycle (IGCC) power plant converts coal to syngas, which is mainly composed of hydrogen and carbon monoxide, by the gasification process and produces electric power by the gas and steam turbine combined cycle power plant. The purpose of this study is to investigate the influence of using syngas in a gas turbine, originally designed for natural gas fuel, on its performance. A commercial gas turbine is selected and variations of its performance characteristics due to adopting syngas is analyzed by simulating off-design gas turbine operation. Since the heating value of the syngas is lower, compared to natural gas, IGCC plants require much larger fuel flow rate. This increase the gas flow rate to the turbine and the pressure ratio, leading to far larger power output and higher thermal efficiency. Examination of using two different syngases reveals that the gas turbine performance varies much with the fuel composition

  12. Effects of bioethanol ultrasonic generated aerosols application on diesel engine performances

    Directory of Open Access Journals (Sweden)

    Mariasiu Florin

    2015-01-01

    Full Text Available In this paper the effects of an experimental bioethanol fumigation application using an experimental ultrasound device on performance and emissions of a single cylinder diesel engine have been experimentally investigated. Engine performance and pollutant emissions variations were considered for three different types of fuels (biodiesel, biodiesel-bioethanol blend and biodiesel and fumigated bioethanol. Reductions in brake specific fuel consumption and NOx pollutant emissions are correlated with the use of ultrasonic fumigation of bioethanol fuel, comparative to use of biodiesel-bioethanol blend. Considering the fuel consumption as diesel engine’s main performance parameter, the proposed bioethanol’s fumigation method, offers the possibility to use more efficient renewable biofuels (bioethanol, with immediate effects on environmental protection.

  13. Development of a High-Performance Fin-and-Tube Heat Exchanger with Vortex Generators for a Vending Machine

    Science.gov (United States)

    Iwasaki, Masamichi; Saito, Hiroshi; Mochizuki, Sadanari; Murata, Akira

    The effect of delta-wing-vortex generators (combination of a delta wing and a delta winglet pair) on the heat transfer performance of fin-and-tube heat exchangers for vending machines has been investegated. Flow visualizations, numerical simulations and heat transfer experiments were conducted to find an optimum geometrical shape and arrangement of the vortex generators. Maximum heat transfer enhancement was achieved by the combination of (a) the delta wing with the apex angle of 86 degrees and (b) the delta winglet pair with the inline angle of 45 degrees. In relatively low Reynolds number range, about 40 % increase in heat transfer coefficient was attained with the above mentioned combination of the vortex generators compared to the ordinary heat exchangers with plain fins. It was revealed that the heat transfer enhancement was attributed to (1) the longitudinal vortexes generated by the delta wing and (2) the reduction of wake area behind the tube. It was also found that an increase in the apex angle of the delta wing brought about heat transfer enhancement, and the scale as well as the streggth of the induced longitudinal vortices played an important role in the heat transfer performance.

  14. Performance Evaluation of Electrochem's PEM Fuel Cell Power Plant for NASA's 2nd Generation Reusable Launch Vehicle

    Science.gov (United States)

    Kimble, Michael C.; Hoberecht, Mark

    2003-01-01

    NASA's Next Generation Launch Technology (NGLT) program is being developed to meet national needs for civil and commercial space access with goals of reducing the launch costs, increasing the reliability, and reducing the maintenance and operating costs. To this end, NASA is considering an all- electric capability for NGLT vehicles requiring advanced electrical power generation technology at a nominal 20 kW level with peak power capabilities six times the nominal power. The proton exchange membrane (PEM) fuel cell has been identified as a viable candidate to supply this electrical power; however, several technology aspects need to be assessed. Electrochem, Inc., under contract to NASA, has developed a breadboard power generator to address these technical issues with the goal of maximizing the system reliability while minimizing the cost and system complexity. This breadboard generator operates with dry hydrogen and oxygen gas using eductors to recirculate the gases eliminating gas humidification and blowers from the system. Except for a coolant pump, the system design incorporates passive components allowing the fuel cell to readily follow a duty cycle profile and that may operate at high 6:1 peak power levels for 30 second durations. Performance data of the fuel cell stack along with system performance is presented to highlight the benefits of the fuel cell stack design and system design for NGLT vehicles.

  15. Analysis of Human Error Types and Performance Shaping Factors in the Next Generation Main Control Room

    International Nuclear Information System (INIS)

    Sin, Y. C.; Jung, Y. S.; Kim, K. H.; Kim, J. H.

    2008-04-01

    Main control room of nuclear power plants has been computerized and digitalized in new and modernized plants, as information and digital technologies make great progresses and become mature. Survey on human factors engineering issues in advanced MCRs: Model-based approach, Literature survey-based approach. Analysis of human error types and performance shaping factors is analysis of three human errors. The results of project can be used for task analysis, evaluation of human error probabilities, and analysis of performance shaping factors in the HRA analysis

  16. Comparison of the performance, advantages and disadvantages of nuclear power generation compared to other clean sources of electricity

    International Nuclear Information System (INIS)

    Mata, Jônatas F.C. da; Neto, Rieder O.; Mesquita, Amir Z.

    2017-01-01

    Nowadays, there is an increase in the demand for electricity in emerging countries, such as India, China and Brazil. There are several alternatives to increase energy generation, and each country has followed certain strategies to achieve this goal. For a long time, developed countries, such as the United States, the United Kingdom and Germany, had focused their efforts on the use of thermoelectric generators through the combustion of non-renewable sources such as coal, natural gas and oil. These examples were followed, also, by the emerging countries. However, pollution levels, generated by these sources, have required the breakdown of this paradigm, and the consequent reversal of large investments in clean energy sources, such as hydraulics, solar and wind. Nucleo-electric energy is also considered a clean energy source, since it does not generate polluting gases during the processing of concentrated uranium in nuclear reactors. In addition, all radioactive waste occupying relatively small volumes and being stored in controlled deposits, in aspects of health, environment and safety. The objective of this article is to compare the performance, in economic, environmental and safety aspects, of nuclear power in relation to renewable energy sources. The results show that nuclear energy has become increasingly competitive in all these fields, justifying the growth of investments in new nuclear technologies. Therefore, the coexistence between the use of clean sources of electricity and the thermonuclear matrix will bring, for humanity, truly sustainable systems of energy generation. (author)

  17. Comparison of the performance, advantages and disadvantages of nuclear power generation compared to other clean sources of electricity

    Energy Technology Data Exchange (ETDEWEB)

    Mata, Jônatas F.C. da; Neto, Rieder O., E-mail: jonatasfmata@yahoo.com.br, E-mail: rieder.neto@gmail.com [Universidade do Estado de Minas Gerais (UEMG), João Monlevade, MG (Brazil); Mesquita, Amir Z., E-mail: amir@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    Nowadays, there is an increase in the demand for electricity in emerging countries, such as India, China and Brazil. There are several alternatives to increase energy generation, and each country has followed certain strategies to achieve this goal. For a long time, developed countries, such as the United States, the United Kingdom and Germany, had focused their efforts on the use of thermoelectric generators through the combustion of non-renewable sources such as coal, natural gas and oil. These examples were followed, also, by the emerging countries. However, pollution levels, generated by these sources, have required the breakdown of this paradigm, and the consequent reversal of large investments in clean energy sources, such as hydraulics, solar and wind. Nucleo-electric energy is also considered a clean energy source, since it does not generate polluting gases during the processing of concentrated uranium in nuclear reactors. In addition, all radioactive waste occupying relatively small volumes and being stored in controlled deposits, in aspects of health, environment and safety. The objective of this article is to compare the performance, in economic, environmental and safety aspects, of nuclear power in relation to renewable energy sources. The results show that nuclear energy has become increasingly competitive in all these fields, justifying the growth of investments in new nuclear technologies. Therefore, the coexistence between the use of clean sources of electricity and the thermonuclear matrix will bring, for humanity, truly sustainable systems of energy generation. (author)

  18. Design specifications to ensure flow-induced vibration and fretting-wear performance in CANDU steam generators and heat exchangers

    International Nuclear Information System (INIS)

    Janzen, V.P.; Han, Y.; Pettigrew, M.J.

    2009-01-01

    Preventing flow-induced vibration and fretting-wear problems in steam generators and heat exchangers requires design specifications that bring together specific guidelines, analysis methods, requirements and appropriate performance criteria. This paper outlines the steps required to generate and support such design specifications for CANDU nuclear steam generators and heat exchangers, and relates them to typical steam-generator design features and computer modeling capabilities. It also describes current issues that are driving changes to flow-induced vibration and fretting-wear specifications that can be applied to the design process for component refurbishment, replacement or new designs. These issues include recent experimental or field evidence for new excitation mechanisms, e.g., the possibility of in-plane fluidelastic instability of U-tubes, the demand for longer reactor and component lifetimes, the need for better predictions of dynamic properties and vibration response, e.g., two-phase random-turbulence excitation, and requirements to consider system 'excursions' or abnormal scenarios, e.g., a main steam line break in the case of steam generators. The paper describes steps being taken to resolve these issues. (author)

  19. Performance and Potential Study of 10kW Wind Turbine Generator for 6 Cities in Malaysia

    OpenAIRE

    Mustaqimah Mustaqimah

    2013-01-01

    ABSTRACT. This study presents an analysis of the optimization by using HOMER software and financial viability of 10 kW wind turbine generator (WTG) through grid connected system for six different locations in Malaysia (Mersing, Kuching, K.Trengganu, Kudat, Melaka and Labuan). Assessment criteria comprised Total Net Present Cost (TNPC), and Cost of Energy ( COE ). The HOMER ( National Renewable Energy laboratory, US) was utilized as the assessment tool with modeling performed with hourly load ...

  20. Thermal Performance of Motor and Inverter in an Integrated Starter Generator System for a Hybrid Electric Vehicle

    OpenAIRE

    Sung Chul Kim

    2013-01-01

    If the integrated starter generator (ISG) motor and inverter operate under continuously high loading conditions, the system’s performance and durability will decrease and the heat dissipation requirements will increase. Therefore, in this study, we developed two cooling designs for the ISG motor and inverter, and then carried out both a model analysis and an experiment on the fluid flow and thermal characteristics of the system under various operating conditions. As the outdoor temperature in...

  1. Towards a new generation of mission planning systems: Flexibility and performance

    Science.gov (United States)

    Gasquet, A.; Parrod, Y.; Desaintvincent, A.

    1994-01-01

    This paper presents some new approaches which are required for a better adequacy of Mission Planning Systems. In particular, the performance flexibility and genericity issues are discussed based on experience acquired through various Mission Planning systems developed by Matra Marconi Space.

  2. Investigation of Battery Heat Generation and Key Performance Indicator Efficiency Using Isothermal Calorimeter

    DEFF Research Database (Denmark)

    Khan, Mohammad Rezwan; Kær, Søren Knudsen

    2016-01-01

    In this experiment-based research, the performance and behaviour of a pouch type Li-ion battery cell are reported. The commercial test cell has a Lithium Titanate Oxide (LTO) based anode with 13Ah capacity. It is accomplished by measuring the evolution of surface temperature distribution, and the...

  3. Performance of Microbial Fuel Cell for Wastewater Treatment and Electricity Generation

    Directory of Open Access Journals (Sweden)

    Z Yavari

    2013-06-01

    Full Text Available Renewable energy will have an important role as a resource of energy in the future. Microbial fuel cell (MFC is a promising method to obtain electricity from organic matter andwastewater treatment simultaneously. In a pilot study, use of microbial fuel cell for wastewater treatment and electricity generation investigated. The bacteria of ruminant used as inoculums. Synthetic wastewater used at different organic loading rate. Hydraulic retention time was aneffective factor in removal of soluble COD and more than 49% removed. Optimized HRT to achieve the maximum removal efficiency and sustainable operation could be regarded 1.5 and 2.5 hours. Columbic efficiency (CE affected by organic loading rate (OLR and by increasing OLR, CE reduced from 71% to 8%. Maximum voltage was 700mV. Since the microbial fuel cell reactor considered as an anaerobic process, it may be an appropriate alternative for wastewater treatment

  4. Gasdynamic performance in relation to the power extraction of an MHD generator

    International Nuclear Information System (INIS)

    Massee, P.

    1983-01-01

    A study of the gasdynamical processes in MHD generators has been made both theoretically and experimentally. A core flow and boundary layer model has been developed. In order to obtain a fast computer code which can be used for engineering purposes the quasi-one-dimensional approximation is used. It is shown in this thesis that the boundary layers have to be calculated from integral equations describing momentum, kinetic energy and stagnation enthalpy respectively, when the MHD effects in the boundary layers are properly taken into account. Calculations with the developed core flow and boundary layer model have shown that the electrical power output is limited by the design of the existing facility and have indicated possibilities to circumvent this limitation. (Auth.)

  5. The Global Seismographic Network (GSN): Deployment of Next Generation VBB Borehole Sensors and Improving Overall Network Noise Performance

    Science.gov (United States)

    Hafner, K.; Davis, P.; Wilson, D.; Sumy, D.

    2017-12-01

    The Global Seismographic Network (GSN) recently received delivery of the next generation Very Broadband (VBB) borehole sensors purchased through funding from the DOE. Deployment of these sensors will be underway during the end of summer and fall of 2017 and they will eventually replace the aging KS54000 sensors at approximately one-third of the GSN network stations. We will present the latest methods of deploying these sensors in the existing deep boreholes. To achieve lower noise performance at some sites, emplacement in shallow boreholes might result in lower noise performance for the existing site conditions. In some cases shallow borehole installations may be adapted to vault stations (which make up two thirds of the network), as a means of reducing tilt-induced signals on the horizontal components. The GSN is creating a prioritized list of equipment upgrades at selected stations with the ultimate goal of optimizing overall network data availability and noise performance. For an overview of the performance of the current GSN relative to selected set of metrics, we are utilizing data quality metrics and Probability Density Functions (PDFs)) generated by the IRIS Data Management Centers' (DMC) MUSTANG (Modular Utility for Statistical Knowledge Gathering) and LASSO (Latest Assessment of Seismic Station Observations) tools. We will present our metric analysis of GSN performance in 2016, and show the improvements at GSN sites resulting from recent instrumentation and infrastructure upgrades.

  6. Performance Evaluation of New Generation CdZnTe Detectors for Safeguards Applications

    International Nuclear Information System (INIS)

    Ivanovs, V.; Mintcheva, J.; Berlizov, A.; Lebrun, A.

    2015-01-01

    Cadmium zinc telluride detectors (CdZnTe) have found a wide application in nondestructive assay measurements in the IAEA's verification practice. It is because of their form factor, usability, sensitivity and good spectral characteristics that they are extensively used for fresh and spent fuel attribute test measurements. Until now, the series of CdZnTe detectors utilized in the IAEA have covered the range of 5 mm 3 , 20 mm 3 , 60 mm 3 and 500mm 3 of sensitive volume. Recently, new CdZnTe detectors with improved spectroscopic characteristics and significantly bigger active volume have become available, owing to advances in crystal and detector manufacturing and signal processing technologies. The distinctive feature of this new technological development is the application of a low-intensity monochromatic optical stimulation with infrared (IR) light. The use of IR illumination with a properly chosen wavelength close to the absorption edge of the CdZnTe can significantly improve the performance of the detectors. Recognizing potential benefits of these detectors in safeguards applications, the IAEA has performed an evaluation of their performance characteristics. Under evaluation were several new detectors with sensitive volumes of 500 mm 3 , 1500 mm 3 and 4000 mm 3 , as well as all-in-one 60 mm 3 , 500 mm 3 and 1500 mm 3 integrated micro-spectrometers available from RITEC, Latvia. In addition to the standard performance characteristics, such as energy resolution, peak shape, efficiency, linearity, throughput and temperature stability, the potential use of the detectors for safeguards specific measurements, such as uranium enrichment with infinite thickness method, was of particular interest. The paper will describe the advances in the CdZnTe detector technology and present the results of their performance evaluation. (author)

  7. Performance analysis of different ORC configurations for thermal energy and LNG cold energy hybrid power generation system

    Science.gov (United States)

    Sun, Zhixin; Wang, Feng; Wang, Shujia; Xu, Fuquan; Lin, Kui

    2017-01-01

    This paper presents a thermal energy and Liquefied natural gas (LNG) cold energy hybrid power generation system. Performances of four different Organic Rankine cycle (ORC) configurations (the basic, the regenerative, the reheat and the regenerative-reheat ORCs) are studied based on the first and the second law of thermodynamics. Dry organic fluid R245fa is selected as the typical working fluid. Parameter analysis is also conducted in this paper. The results show that regeneration could not increase the thermal efficiency of the thermal and cold energy hybrid power generation system. ORC with the reheat process could produce more specific net power output but it may also reduce the system thermal efficiency. The basic and the regenerative ORCs produce higher thermal efficiency while the regenerative-reheat ORC performs best in the exergy efficiency. A preheater is necessary for the thermal and cold energy hybrid power generation system. And due to the presence of the preheater, there will be a step change of the system performance as the turbine inlet pressure rises.

  8. High-performance ionic diode membrane for salinity gradient power generation.

    Science.gov (United States)

    Gao, Jun; Guo, Wei; Feng, Dan; Wang, Huanting; Zhao, Dongyuan; Jiang, Lei

    2014-09-03

    Salinity difference between seawater and river water is a sustainable energy resource that catches eyes of the public and the investors in the background of energy crisis. To capture this energy, interdisciplinary efforts from chemistry, materials science, environmental science, and nanotechnology have been made to create efficient and economically viable energy conversion methods and materials. Beyond conventional membrane-based processes, technological breakthroughs in harvesting salinity gradient power from natural waters are expected to emerge from the novel fluidic transport phenomena on the nanoscale. A major challenge toward real-world applications is to extrapolate existing single-channel devices to macroscopic materials. Here, we report a membrane-scale nanofluidic device with asymmetric structure, chemical composition, and surface charge polarity, termed ionic diode membrane (IDM), for harvesting electric power from salinity gradient. The IDM comprises heterojunctions between mesoporous carbon (pore size ∼7 nm, negatively charged) and macroporous alumina (pore size ∼80 nm, positively charged). The meso-/macroporous membrane rectifies the ionic current with distinctly high ratio of ca. 450 and keeps on rectifying in high-concentration electrolytes, even in saturated solution. The selective and rectified ion transport furthermore sheds light on salinity-gradient power generation. By mixing artificial seawater and river water through the IDM, substantially high power density of up to 3.46 W/m(2) is discovered, which largely outperforms some commercial ion-exchange membranes. A theoretical model based on coupled Poisson and Nernst-Planck equations is established to quantitatively explain the experimental observations and get insights into the underlying mechanism. The macroscopic and asymmetric nanofluidic structure anticipates wide potentials for sustainable power generation, water purification, and desalination.

  9. Dielectric barrier discharge plasma atomizer for hydride generation atomic absorption spectrometry—Performance evaluation for selenium

    Energy Technology Data Exchange (ETDEWEB)

    Duben, Ondřej [Institute of Analytical Chemistry of the CAS, v.v.i., Veveří 97, CZ-602 00 Brno (Czech Republic); Faculty of Science, Department of Analytical Chemistry, Charles University in Prague, Hlavova 8, Prague, CZ 128 43 Czech Republic (Czech Republic); Boušek, Jaroslav [Faculty of Electrical Engineering and Communications, Brno University of Technology, Technická 1058/10, 61600 Brno (Czech Republic); Dědina, Jiří [Institute of Analytical Chemistry of the CAS, v.v.i., Veveří 97, CZ-602 00 Brno (Czech Republic); Kratzer, Jan, E-mail: jkratzer@biomed.cas.cz [Institute of Analytical Chemistry of the CAS, v.v.i., Veveří 97, CZ-602 00 Brno (Czech Republic)

    2015-09-01

    Atomization of selenium hydride in a quartz dielectric barrier discharge (DBD) atomizer was optimized and its performance was compared to that of the externally heated quartz multiatomizer. Argon was found as the best DBD discharge gas employing a flow rate of 75 ml min{sup −1} Ar while the DBD power was optimized at 14 W. The detection limits reached 0.24 ng ml{sup −1} Se in the DBD and 0.15 ng ml{sup −1} Se in the multiatomizer. The tolerance of DBD to interferences is even better than with the multiatomizer. - Highlights: • SeH{sub 2} atomization in a dielectric barrier discharge (DBD) was optimized for AAS. • Atomizer performance was compared for DBD and externally heated quartz atomizer. • Detection limits were quantified and interferences were studied in both atomizers. • Atomization efficiency in the DBD was estimated.

  10. Enhancing performance of next generation FSO communication systems using soft computing-based predictions.

    Science.gov (United States)

    Kazaura, Kamugisha; Omae, Kazunori; Suzuki, Toshiji; Matsumoto, Mitsuji; Mutafungwa, Edward; Korhonen, Timo O; Murakami, Tadaaki; Takahashi, Koichi; Matsumoto, Hideki; Wakamori, Kazuhiko; Arimoto, Yoshinori

    2006-06-12

    The deterioration and deformation of a free-space optical beam wave-front as it propagates through the atmosphere can reduce the link availability and may introduce burst errors thus degrading the performance of the system. We investigate the suitability of utilizing soft-computing (SC) based tools for improving performance of free-space optical (FSO) communications systems. The SC based tools are used for the prediction of key parameters of a FSO communications system. Measured data collected from an experimental FSO communication system is used as training and testing data for a proposed multi-layer neural network predictor (MNNP) used to predict future parameter values. The predicted parameters are essential for reducing transmission errors by improving the antenna's accuracy of tracking data beams. This is particularly essential for periods considered to be of strong atmospheric turbulence. The parameter values predicted using the proposed tool show acceptable conformity with original measurements.

  11. Performance analysis of electricity generation by the medium temperature geothermal resources: Velika Ciglena case study

    International Nuclear Information System (INIS)

    Rašković, Predrag; Guzović, Zvonimir; Cvetković, Svetislav

    2013-01-01

    During the last decade, a design of an energy efficient and cost effective geothermal plant represents a significant and on-going technical challenge in all the Western Balkan countries. In the Republic of Croatia, the geothermal field Velika Ciglena is identified as one of the most valuable geothermal heat sources and probably the location where the first geothermal plant in the Western Balkan area will be built. The purpose of this work is the conceptual design and performance analysis of the binary plants–the one which operates under the Organic Rankine Cycle (ORC) and the other under Kalina (KLN) cycle–which can be used for geothermal energy utilization in Velika Ciglena. A conceptual plant design is performed by the equation-oriented modelling approach and supported by the two steady-state spreadsheet simulators. The performance analysis of all design solutions is conducted through energy and exergy analysis, and by the estimated total cost of operating units in the plant. The results of the analysis indicate that the plant design based on the ORC cycle has a higher thermodynamic efficiency and lower cost of equipment, and consequently, it is more suitable for the future geothermal plant in Velika Ciglena. - Highlights: ► Paper presents the analysis of binary geothermal plant for the utilization of recourses in Velika Ciglena field (Croatia). ► Thermodynamic and economical parameters of both cycles are calculated by the spreadsheet simulation software. ► The results of performance analysis indicate the advantage of electricity production based on ORC cycle

  12. Design and performance prediction of a new generation adsorption chiller using composite adsorbent

    International Nuclear Information System (INIS)

    Gong, L.X.; Wang, R.Z.; Xia, Z.Z.; Chen, C.J.

    2011-01-01

    Research highlights: → Composite adsorbent 'employing lithium chloride in silica gel' and water as working pair. → A new type adsorbent bed is used to accommodate the composite adsorbent. → A dynamic model of the adsorption chiller is built. → The coefficient of performance (COP) and the cooling capacity will be improved. -- Abstract: This paper presents a novel adsorption chiller using composite adsorbent 'employing lithium chloride in silica gel' as adsorbent and water as adsorbate. A new type adsorbent bed is used to accommodate the composite adsorbent. The mass recovery between two adsorbent beds usually results in the adsorbate unbalance. So a novel auto water makeup unite is used to solve the problem. A dynamic model of the adsorption chiller is built based on the adsorption isotherms to predict the performance. The simulation result shows that the coefficient of performance (COP) and the cooling capacity will increase by using this new composite adsorbent. When the temperatures of hot water inlet, cooling water inlet, and chilled water inlet are 363, 303 and 293 K, COP will be 0.43, and the cooling capacity will be 5.295 kW. Also operation strategy is optimized. Different temperatures of hot water inlet, cooling water inlet and chilling water inlet will result in different COP and cooling capacity.

  13. Performance analysis of an integrated biomass gasification and PEMFC (proton exchange membrane fuel cell) system: Hydrogen and power generation

    International Nuclear Information System (INIS)

    Chutichai, Bhawasut; Authayanun, Suthida; Assabumrungrat, Suttichai; Arpornwichanop, Amornchai

    2013-01-01

    The PEMFC (proton exchange membrane fuel cell) is expected to play a significant role in next-generation energy systems. Because most hydrogen that is used as a fuel for PEMFCs is derived from the reforming of natural gas, the use of renewable energy sources such as biomass to produce this hydrogen offers a promising alternative. This study is focused on the performance analysis of an integrated biomass gasification and PEMFC system. The combined heat and power generation output of this integrated system is designed for residential applications, taking into account thermal and electrical demands. A flowsheet model of the integrated PEMFC system is developed and employed to analyze its performance with respect to various key operating parameters. A purification process consisting of a water–gas shift reactor and a preferential oxidation reactor is also necessary in order to reduce the concentration of CO in the synthesis gas to below 10 ppm for subsequent use in the PEMFC. The effect of load level on the performance of the PEMFC system is investigated. Based on an electrical load of 5 kW, it is found that the electrical efficiency of the PEMFC integrated system is 22%, and, when waste heat recovery is considered, the total efficiency of the PEMFC system is 51%. - Highlights: • Performance of a biomass gasification and PEMFC integrated system is analyzed. • A flowsheet model of the PEMFC integrated system is developed. • Effect of biomass sources and key parameters on hydrogen and power generation is presented. • The PEMFC integrated system is designed for small-scale power demand. • Effect of load changes on the performance of PEMFC is investigated

  14. A unified model for energy and environmental performance assessment of natural gas-fueled poly-generation systems

    International Nuclear Information System (INIS)

    Chicco, Gianfranco; Mancarella, Pierluigi

    2008-01-01

    Poly-generation systems for combined production of manifold energy vectors such as electricity, heat at different enthalpy levels (for instance, in the form of hot water and steam), and cooling power from a unique source of primary energy (typically natural gas) are increasingly spreading, above all on a small-scale basis (below 1 MW e ), owing to their enhanced energy, environmental and economic characteristics. Availability of suitable tools for assessing the performance of such systems is therefore fundamental. In this paper, a unified general model is proposed for assessing the energy and CO 2 emission performance of any type of poly-generation system with natural gas as the energy input. In particular, the classical energy saving model for cogeneration systems is extended to include in the analysis further energy vectors by defining the novel PPES (Poly-generation Primary Energy Saving) indicator. In addition, equivalent efficiencies for CO 2 emission assessment are defined and used in the formulation of the new PCO2ER (Poly-generation CO 2 Emission Reduction) indicator, specifically introduced for environmental analysis. The formal analogy between the PPES and the PCO2ER indicators is highlighted. Numerical applications are provided to show the effectiveness of the proposed models and to quantify the typical benefits that poly-generation systems can bring. In particular, the new indicators are of relevant interest for both energy planners and policy makers, above all in the outlook of formulating financial incentive strategies, as it already occurs for cogeneration systems, or of participating to specific energy-related markets such as the ones for trading white certificates or emission allowances

  15. High speed and high functional inverter power supplies for plasma generation and control, and their performance

    International Nuclear Information System (INIS)

    Uesugi, Yoshihiko; Razzak, Mohammad A.; Kondo, Kenji; Kikuchi, Yusuke; Takamura, Shuichi; Imai, Takahiro; Toyoda, Mitsuhiro

    2003-01-01

    The Rapid development of high power and high speed semiconductor switching devices has led to their various applications in related plasma fields. Especially, a high speed inverter power supply can be used as an RF power source instead of conventional linear amplifiers and a power supply to control the magnetic field in a fusion plasma device. In this paper, RF thermal plasma production and plasma heating experiments are described emphasis placed on using a static induction transistor inverter at a frequency range between 200 kHz and 2.5 MHz as an RF power supply. Efficient thermal plasma production is achieved experimentally by using a flexible and easily operated high power semiconductor inverter power supply. Insulated gate bipolar transistor (IGBT) inverter power supplies driven by a high speed digital signal processor are applied as tokamak joule coil and vertical coil power supplies to control plasma current waveform and plasma equilibrium. Output characteristics, such as the arbitrary bipolar waveform generation of a pulse width modulation (PWM) inverter using digital signal processor (DSP) can be successfully applied to tokamak power supplies for flexible plasma current operation and fast position control of a small tokamak. (author)

  16. Investigating the Thermodynamic Performances of TO-Based Metamaterial Tunable Cells with an Entropy Generation Approach

    Directory of Open Access Journals (Sweden)

    Guoqiang Xu

    2017-10-01

    Full Text Available Active control of heat flux can be realized with transformation optics (TO thermal metamaterials. Recently, a new class of metamaterial tunable cells has been proposed, aiming to significantly reduce the difficulty of fabrication and to flexibly switch functions by employing several cells assembled on related positions following the TO design. However, owing to the integration and rotation of materials in tunable cells, they might lead to extra thermal losses as compared with the previous continuum design. This paper focuses on investigating the thermodynamic properties of tunable cells under related design parameters. The universal expression for the local entropy generation rate in such metamaterial systems is obtained considering the influence of rotation. A series of contrast schemes are established to describe the thermodynamic process and thermal energy distributions from the viewpoint of entropy analysis. Moreover, effects of design parameters on thermal dissipations and system irreversibility are investigated. In conclusion, more thermal dissipations and stronger thermodynamic processes occur in a system with larger conductivity ratios and rotation angles. This paper presents a detailed description of the thermodynamic properties of metamaterial tunable cells and provides reference for selecting appropriate design parameters on related positions to fabricate more efficient and energy-economical switchable TO devices.

  17. Evaluating the Environmental Performance of the U.S. Next Generation Air Transportation System

    Science.gov (United States)

    Graham, Michael; Augustine, Stephen; Ermatinger, Christopher; Difelici, John; Thompson, Terence R.; Marcolini, Michael A.; Creedon, Jeremiah F.

    2009-01-01

    The environmental impacts of several possible U.S. Next Generation Air Transportation scenarios have been quantitatively evaluated for noise, air-quality, fuel-efficiency, and CO2 impacts. Three principal findings have emerged. (1) 2025 traffic levels about 30% higher than 2006 are obtained by increasing traffic according to FAA projections while also limiting traffic at each airport using reasonable ratios of demand to capacity. NextGen operational capabilities alone enable attainment of an additional 10-15% more flights beyond that 2025 baseline level with negligible additional noise, air-quality, and fuel-efficiency impacts. (2) The addition of advanced engine and airframe technologies provides substantial additional reductions in noise and air-quality impacts, and further improves fuel efficiency. 2025 environmental goals based on projected system-wide improvement rates of about 1% per year for noise and fuel-efficiency (an air-quality goal is not yet formulated) are achieved using this new vehicle technology. (3) Overall air-transport "product", as measured by total flown distance or total payload distance, increases by about 50% relative to 2006, but total fuel consumption and CO2 production increase by only about 40% using NextGen operational capabilities. With the addition of advanced engine/airframe technologies, the increase in total fuel consumption and CO2 production can be reduced to about 30%.

  18. A report on the performance of a grid connected photovoltaic power generation system

    International Nuclear Information System (INIS)

    Mohd Azhar Abdul Rahman; Mohd Surif Abdul Wahab; Azmi Omar

    2000-01-01

    Malaysia is located almost on the equator and is blessed with an abundance of sunlight almost all year round. So obviously, with the right planning and strategies that are coupled to the right technology and development in the market, the potential for photovoltaic system as an alternative source of power in this country looks promising and is constantly gaining ground and popularity. Sunlight is free and the photovoltaic system is also emission and pollution free which is a guest boost to the current worldwide effort to reduce the global environmental problems. Utility giant Tenaga Nasional Berhad is in line with the Government aspiration to promote the development of solar photovoltaic in the country, who believe in the success and acceptance potential of the photovoltaic system as an alternative source of power generation for long term energy option. In March 1998, a contract was awarded by Tenaga Nasional Berhad to its research subsidiary, Tenaga Nasional Research and Development Sdn. Bhd. to undertake a pilot research project on the development of a grid connected photovoltaic system. This research project is co-funded by the Electric Supply Industry Trust fund. One of the main objective of this research project is to seek the best approach to popularize the Grid Connected Photovoltaic System for domestic as well as suitable commercial premises in this country. This paper will report the initial findings of the project in terms of technical capability and commercial liability. (Author)

  19. Transient Performance Improvement of Wind Turbines with Doubly Fed Induction Generators Using Active Damping Control Strategy

    Directory of Open Access Journals (Sweden)

    Saeed Soleymani

    2016-01-01

    Full Text Available This paper Analytically investigates the effects of system and controller parameters and operating conditions on the dynamic and transient behavior of wind turbines (WTs with doubly-fed induction generators (DFIGs under voltage dips and wind speed fluctuations. Also, it deals with the design considerations regarding rotor and speed controllers. The poorly damped electrical and mechanical modes of the system are identified, and the effects of system parameters, and speed/rotor controllers on these modes are investigated by modal and sensitivity analyses. The results of theoretical studies are verified by time domain simulations. It is found that the dynamic behavior of the DFIG-based WT under voltage dips is strongly affected by the stator dynamics. Further, it is shown that the closed loop bandwidth of the rotor current control, rotor current damping, DFIG power factor and the rotor back-emf voltages have high impact on the stator modes and consequently on the DFIG dynamic behavior. Moreover, it is shown that the dynamic behavior of DFIG-based WT under wind speed fluctuation is significantly dependent on the bandwidth and damping of speed control loop.

  20. Performance assessment of electric power generations using an adaptive neural network algorithm and fuzzy DEA

    Energy Technology Data Exchange (ETDEWEB)

    Javaheri, Zahra

    2010-09-15

    Modeling, evaluating and analyzing performance of Iranian thermal power plants is the main goal of this study which is based on multi variant methods analysis. These methods include fuzzy DEA and adaptive neural network algorithm. At first, we determine indicators, then data is collected, next we obtained values of ranking and efficiency by Fuzzy DEA, Case study is thermal power plants In view of the fact that investment to establish on power plant is very high, and maintenance of power plant causes an expensive expenditure, moreover using fossil fuel effected environment hence optimum produce of current power plants is important.

  1. Low Cost High Performance Generator Technology Program. Volume 5. Heat pipe topical, appendices

    International Nuclear Information System (INIS)

    1975-07-01

    Work performed by Dynatherm Corporation for Teledyne Isotopes during a program entitled ''Heat Pipe Fabrication, Associated Technical Support and Reporting'' is reported. The program was initiated on November 29, 1972; the main objectives were accomplished with the delivery of the heat pipes for the HPG. Life testing of selected heat pipe specimens is continuing to and beyond the present date. The program consisted of the following tasks: Heat Pipe Development of Process Definition; Prototype Heat Pipes for Fin Segment Test; HPG Heat Pipe Fabrication and Testing; Controlled Heat Pipe Life Test; and Heat Pipe Film Coefficient Determination

  2. Internalization Mediation towards the Relationship between Entrepreneurial Action and Individual Performance for the Next Generation of Family Companies in Surabaya

    Directory of Open Access Journals (Sweden)

    Carolina Novi Mustikarini

    2017-06-01

    Full Text Available This study  examined the effect of entrepreneurial action for the performance of the next generation using the sample of students who joined the Family Business Community. In this study, there is a high contribution given by the role of entrepreneurship education in preparing the next generation in the family business. In addition, entrepreneurship education is considered possible through the process of internalization of the leaning process that is going on. For example, it is noted that entrepreneurial action can have a significant effect on the performance of the organization. In the context of the family business and entrepreneurial education at the University of Ciputra, both variables (entrepreneurial action and individual performance are necessary to be tested and therefore, the researcher finds it possible to cary out a research that is supposed to have a contribution to the family business. This study uses a hierarchical regression analysis, to test the stages of the mediation process. The results showed that most of relationships mediate internalization Entrepreneurial Action and Individual Performance.

  3. Performance tests and efficiency analysis of Solar Invictus 53S - A parabolic dish solar collector for direct steam generation

    Science.gov (United States)

    Jamil, Umer; Ali, Wajahat

    2016-05-01

    This paper presents the results of performance tests conducted on Solar Invictus 53S `system'; an economically effective solar steam generation solution designed and developed by ZED Solar Ltd. The system consists of a dual axis tracking parabolic solar dish and bespoke cavity type receiver, which works as a Once Through Solar Steam Generator `OTSSG' mounted at the focal point of the dish. The overall performance and efficiency of the system depends primarily on the optical efficiency of the solar dish and thermal efficiency of the OTSSG. Optical testing performed include `on sun' tests using CCD camera images and `burn plate' testing to evaluate the sunspot for size and quality. The intercept factor was calculated using a colour look-back method to determine the percentage of solar rays focused into the receiver. Solar dish tracking stability tests were carried out at different times of day to account for varying dish elevation angles and positions, movement of the sunspot centroid was recorded and logged using a CCD camera. Finally the overall performance and net solar to steam efficiency of the system was calculated by experimentally measuring the output steam parameters at varying Direct Normal Insolation (DNI) levels at ZED Solar's test facility in Lahore, Pakistan. Thermal losses from OTSSG were calculated using the known optical efficiency and measured changes in output steam enthalpy.

  4. Accuracy and Reliability in the Prediction of End-of-Life Performance of Solar Generators

    Science.gov (United States)

    Rapp, Etienne

    2008-09-01

    The end-of-life power analysis of solar arrays is calculated using a combination of arithmetic and root square sums of loss factors. These loss factors are sometimes linked to degradations, sometimes linked to uncertainties. The uncertainties of the degradations are taken into account considering contractual "worst cases". This paper will put the first stones for a move "metrological" evaluation of the probable performance associated with a standard uncertainty. The turn from silicon to triple junction solar cells induces some changes in the degradation parameters of solar arrays: * The triple junction cells are more sensitive to UV darkening than silicon ones. * The cell voltage is higher and the current is lower. Then the cell strings are shorter, and there are more strings in parallel. This induces some changes in the reliability analyses and risk management. * The failure modes and failure rates of these cells have to be compared and discussed. We try to define improved rules to design solar arrays for end of life performance, for a better knowledge of the margins and a better reliability.

  5. Evaluation of the 2013 Southeast Asian Haze on Solar Generation Performance.

    Science.gov (United States)

    Maghami, Mohammadreza; Hizam, Hashim; Gomes, Chandima; Hajighorbani, Shahrooz; Rezaei, Nima

    2015-01-01

    Pollution in Southeast Asia is a major public energy problem and the cause of energy losses. A significant problem with respect to this type of pollution is that it decreases energy yield. In this study, two types of photovoltaic (PV) solar arrays were used to evaluate the effect of air pollution. The performance of two types of solar arrays were analysed in this research, namely, two units of a 1 kWp tracking flat photovoltaic (TFP) and two units of a 1 kWp fixed flat photovoltaic arrays (FFP). Data analysis was conducted on 2,190 samples at 30 min intervals from 01st June 2013, when both arrays were washed, until 30th June 2013. The performance was evaluated by using environmental data (irradiation, temperature, dust thickness, and air pollution index), power output, and energy yield. Multiple regression models were predicted in view of the environmental data and PV array output. Results showed that the fixed flat system was more affected by air pollution than the tracking flat plate. The contribution of this work is that it considers two types of photovoltaic arrays under the Southeast Asian pollution 2013.

  6. Evaluation of the 2013 Southeast Asian Haze on Solar Generation Performance

    Science.gov (United States)

    Maghami, Mohammadreza; Hizam, Hashim; Gomes, Chandima; Hajighorbani, Shahrooz; Rezaei, Nima

    2015-01-01

    Pollution in Southeast Asia is a major public energy problem and the cause of energy losses. A significant problem with respect to this type of pollution is that it decreases energy yield. In this study, two types of photovoltaic (PV) solar arrays were used to evaluate the effect of air pollution. The performance of two types of solar arrays were analysed in this research, namely, two units of a 1 kWp tracking flat photovoltaic (TFP) and two units of a 1 kWp fixed flat photovoltaic arrays (FFP). Data analysis was conducted on 2,190 samples at 30 min intervals from 01st June 2013, when both arrays were washed, until 30th June 2013. The performance was evaluated by using environmental data (irradiation, temperature, dust thickness, and air pollution index), power output, and energy yield. Multiple regression models were predicted in view of the environmental data and PV array output. Results showed that the fixed flat system was more affected by air pollution than the tracking flat plate. The contribution of this work is that it considers two types of photovoltaic arrays under the Southeast Asian pollution 2013. PMID:26275303

  7. Performance study of molybdenum gels with titanium for preparation of 99Mo-99mTc generators

    International Nuclear Information System (INIS)

    Moraes, Vanessa; Osso Junior, Joao Alberto

    2005-01-01

    99m Tc is the most used radioisotope in Nuclear Medicine, due to nuclear characteristics. It is obtained by the radioactive decay of 99 Mo, generator of radioisotope system. When 99 Mo is produced by the activation in reactor, the most used technique for the preparation of the generators is the gel type generator, which incorporates 99 Mo to the gel that is insoluble, chemically inert to the solutions and with properties of ion exchange. Several countries had already studied this methodology, as is the case of Vietnam, India, China, Australian. This work has the objective of studying the performance and characterization of molybdenum gels with titanium. Four variables in the preparation of the gel were studied: mass ratio between Mo and Ti (1.80 and 2.25), concentration of NaOH (2 and 4 mol/L), final temperature (25 and 50 deg C) and pH (3.5 and 4.5). The prepared gels were analyzed with relation to the size of its particles, identification of its structure, amount of molybdenum, amount of titanium, profile of elution, pH of the elution, determination of the radioisotopes in the eluate and final radiochemical purity. The final result is a formularization of the gel with the best characteristics for posterior preparation of the generator of 99m Tc- 99 Mo. (author)

  8. Human Leukemic Cells performing Oxidative Phosphorylation (OXPHOS Generate an Antioxidant Response Independently of Reactive Oxygen species (ROS Production

    Directory of Open Access Journals (Sweden)

    Abrar Ul Haq Khan

    2016-01-01

    Full Text Available Tumor cell metabolism is altered during leukemogenesis. Cells performing oxidative phosphorylation (OXPHOS generate reactive oxygen species (ROS through mitochondrial activity. To limit the deleterious effects of excess ROS, certain gene promoters contain antioxidant response elements (ARE, e.g. the genes NQO-1 and HO-1. ROS induces conformational changes in KEAP1 and releases NRF2, which activates AREs. We show in vitro and in vivo that OXPHOS induces, both in primary leukemic cells and cell lines, de novo expression of NQO-1 and HO-1 and also the MAPK ERK5 and decreases KEAP1 mRNA. ERK5 activates the transcription factor MEF2, which binds to the promoter of the miR-23a–27a–24-2 cluster. Newly generated miR-23a destabilizes KEAP1 mRNA by binding to its 3′UTR. Lower KEAP1 levels increase the basal expression of the NRF2-dependent genes NQO-1 and HO-1. Hence, leukemic cells performing OXPHOS, independently of de novo ROS production, generate an antioxidant response to protect themselves from ROS.

  9. The influence of inner topology of exhaust heat exchanger and thermoelectric module distribution on the performance of automotive thermoelectric generator

    International Nuclear Information System (INIS)

    Wang, Yiping; Li, Shuai; Zhang, Yifeng; Yang, Xue; Deng, Yadong; Su, Chuqi

    2016-01-01

    Highlights: • Cylindrical grooves to improve the performance of TEG were proposed. • Mainly thermal resistance in TEG was the heat convection in heat exchanger. • Proper height of heat exchanger can improve the TEG performance. • Keeping heat exchanger partly covered with TEM can make full use of each TEM. - Abstract: The waste heat of automotive exhaust gas would be directly transferred into electricity by thermoelectric modules (TEM) because of the temperature difference between heat exchanger and water tank. For the vehicle thermoelectric generator (TEG), the electrical power generation was deeply influenced by temperature difference, temperature uniformity and topological structure of TEG. In previous works, increasing the difference of temperature would significantly enhance the power generation of TEG and inserted fins were always applied to enhance heat transfer in heat exchanger. However the fins would result in a large unwanted back pressure which went against to the efficiency of the engine. In current studies, in order to enhance heat transfer rates and to avoid back pressure increase, a heat exchanger containing cylindrical grooves (the depth-to-width ratio is 0.25) on the interior surface of heat exchanger was proposed. The cylindrical grooves could increase the heat transfer area and enhance the turbulence intensity, meanwhile there was no additional inserts in the fluid to block the flow. The surface temperatures of water tank and heat exchanger with three internal structures, such as grooved surface, flat surface and inserted fins, were studied by numerical simulation at each row of thermoelectric modules. The results showed that comparing to other structures, heat exchanger with cylindrical grooves could improve the TEG efficiency at a low back pressure. The influence of the channel height on the TEG performance was investigated and the TEG with a channel height of 8 mm showed the best overall performance. It was also found that a portion

  10. The influence of self-generated emotions on physical performance: an investigation of happiness, anger, anxiety, and sadness.

    Science.gov (United States)

    Rathschlag, Marco; Memmert, Daniel

    2013-04-01

    The present study examined the relationship between self-generated emotions and physical performance. All participants took part in five emotion induction conditions (happiness, anger, anxiety, sadness, and an emotion-neutral state) and we investigated their influence on the force of the finger musculature (Experiment 1), the jump height of a counter-movement jump (Experiment 2), and the velocity of a thrown ball (Experiment 3). All experiments showed that participants could produce significantly better physical performances when recalling anger or happiness emotions in contrast to the emotion-neutral state. Experiments 1 and 2 also revealed that physical performance in the anger and the happiness conditions was significantly enhanced compared with the anxiety and the sadness conditions. Results are discussed in relation to the Lazarus (1991, 2000a) cognitive-motivational-relational (CMR) theory framework.

  11. An Efficient Taguchi Approach for the Performance Optimization of Health, Safety, Environment and Ergonomics in Generation Companies.

    Science.gov (United States)

    Azadeh, Ali; Sheikhalishahi, Mohammad

    2015-06-01

    A unique framework for performance optimization of generation companies (GENCOs) based on health, safety, environment, and ergonomics (HSEE) indicators is presented. To rank this sector of industry, the combination of data envelopment analysis (DEA), principal component analysis (PCA), and Taguchi are used for all branches of GENCOs. These methods are applied in an integrated manner to measure the performance of GENCO. The preferred model between DEA, PCA, and Taguchi is selected based on sensitivity analysis and maximum correlation between rankings. To achieve the stated objectives, noise is introduced into input data. The results show that Taguchi outperforms other methods. Moreover, a comprehensive experiment is carried out to identify the most influential factor for ranking GENCOs. The approach developed in this study could be used for continuous assessment and improvement of GENCO's performance in supplying energy with respect to HSEE factors. The results of such studies would help managers to have better understanding of weak and strong points in terms of HSEE factors.

  12. A High Performance PSO-Based Global MPP Tracker for a PV Power Generation System

    Directory of Open Access Journals (Sweden)

    Kuei-Hsiang Chao

    2015-07-01

    Full Text Available This paper aims to present an improved version of a typical particle swarm optimization (PSO algorithm, such that the global maximum power point (MPP on a P-V characteristic curve with multiple peaks can be located in an efficient and precise manner for a photovoltaic module array. A series of instrumental measurements are conducted on variously configured arrays built with SANYO HIP2717 PV modules, either unshaded, partially shaded, or malfunctioning, as the building blocks. There appear two, triple and quadruple peaks on the corresponding P-V characteristic curves. Subsequently, the tracking performance comparisons, made by some practical experiments, indicate the superiority of this improved MPP tracking algorithm over the typical one.

  13. Thermodynamic Simulation on the Performance of Twin Screw Expander Applied in Geothermal Power Generation

    Directory of Open Access Journals (Sweden)

    Yuanqu Qi

    2016-08-01

    Full Text Available A three-dimensional (3D geometry model of twin screw expander has been developed in this paper to measure and analyze geometric parameters such as groove volume, suction port area, and leakage area, which can be described as functions of rotation angle of male rotor. Taking the suction loss, leakage loss, and real gas effect into consideration, a thermodynamic model is developed using continuity and energy conservation equation. The developed model is verified by comparing predicted results of power output and internal efficiency with experimental data. Based on the model, the relationship between mass flow rate through inlet port and leakage path with rotation angle of male rotor as well as effects of the inlet parameter and operating parameter on the performance of the expander are analyzed.

  14. Performance Evaluation of Throatless Gasifier Using Pine Needles as a Feedstock for Power Generation

    Directory of Open Access Journals (Sweden)

    Dhaundiyal Alok

    2016-03-01

    Full Text Available This paper deals with the performance evaluation of a throatless gasifier TG-SI-10E. Evaluation of the throatless gasifier was done in three streams, which were the thermal, design and economic aspects. It was tested with pine needles, derived from the Himalayan chir pine (Pinus roxburghii. A non-isokinetic sampling technique was used for measuring the tar and dust contents. The carbon dioxide and carbon monoxide emission at the exhaust of engine was in the range of 12.8% and 0.1-0.5% respectively. The maximum temperature of producer gas measured at the outlet of the gasifier was 505 °C. The specific biomass consumption rate of pine needles was calculated to be 1.595 kg/kWh (electrical. Specific gasification rate for the given design was found to be 107 kg/m2h. Economic evaluation was based on direct tax incidence.

  15. New generation of single-chip microcomputers focused on cost performance

    Energy Technology Data Exchange (ETDEWEB)

    Akao, Y.; Iwashita, H. (Hitachi, Ltd., Tokyo (Japan))

    1993-06-01

    A single-chip microcomputer which incorporates a CPU (central processing unit), memory, and peripheral functions in one chip has been increasingly applied to various fields as the heart of electronic equipment in terms of its economy, compactness, lightness, and suitability for mass production. In response to a wide variety of needs, a lineup must have substantial breadth with regard to performance, on-chip memory capacity, on-chip peripheral functions, operating voltage, and packaging. In particular, low-voltage high-speed operation, high integration, expanded address space, and improved software productivity, which are required for mobile communication terminals, are the common needs for single-chip microcomputers. In accordance with these needs, Hitachi has been actively developing new products. The present paper introduces Hitachi's lineup of single-chip microcomputers. 10 figs., 1 tab.

  16. Performance Evaluation of Speech Recognition Systems as a Next-Generation Pilot-Vehicle Interface Technology

    Science.gov (United States)

    Arthur, Jarvis J., III; Shelton, Kevin J.; Prinzel, Lawrence J., III; Bailey, Randall E.

    2016-01-01

    During the flight trials known as Gulfstream-V Synthetic Vision Systems Integrated Technology Evaluation (GV-SITE), a Speech Recognition System (SRS) was used by the evaluation pilots. The SRS system was intended to be an intuitive interface for display control (rather than knobs, buttons, etc.). This paper describes the performance of the current "state of the art" Speech Recognition System (SRS). The commercially available technology was evaluated as an application for possible inclusion in commercial aircraft flight decks as a crew-to-vehicle interface. Specifically, the technology is to be used as an interface from aircrew to the onboard displays, controls, and flight management tasks. A flight test of a SRS as well as a laboratory test was conducted.

  17. High-temperature performance of a new nickel-based filler metal for power generation application

    Energy Technology Data Exchange (ETDEWEB)

    Shingledecker, J.; Coleman, K. [Electric Power Research Institute, Charlotte, NC (United States); Siefert, J.; Tanzosh, J. [Babcok and Wilcox Research Center, Barberton, OH (United States); Newell, W. [Euroweld, Mooresville, NC (United States)

    2010-07-01

    A new nickel-based weld filler metal, EPRI P87, has been developed as a superior alternative to ERNiCr-3 for use in dissimilar metal welds (DMW) between ferritic and austenitic materials. EPRI P87 has a low coefficient of thermal expansion more closely matching alloys such as Grade 91 and 92 than other available filler metals. Additionally, the size of the carbon denuded region adjacent to the weld in the heat-affected-zone is minimized/eliminated by proper control of weld metal composition. In this work the high-temperature mechanical behavior of DMWs utilizing EPRI P87 (GTAW and GMAW processes) was characterized through tensile and long-term creep-rupture testing. Microstructure analysis was also conducted on tested specimens to evaluate the HAZ regions and failure modes. Performance of the weld metal and welded joints is discussed and compared with ERNiCr-3 and typical 9%Cr-MoV filler metals. (orig.)

  18. Stellar performance: top honor for Tesco - new generation of mechanical muscle sells like hot cakes

    International Nuclear Information System (INIS)

    Jaremko, G.

    1997-01-01

    Tesco Corporation, a Calgary-based oil field equipment supply company, was recently awarded the 1997 Canada Export Award. The award was for top performance in selling, leasing and maintaining (all in one package) a top drive unit. The unit rotates drills up from rig floors to the top of the pipe strings that drive the drill bits into the earth. There are currently some 130 Tesco machines in action despite heavy competition from industry giant Varco and others. Tesco is also developing new product lines for the rapidly developing 'underbalanced drilling' market, and is testing a new concept for simultaneous drilling and casing of wells. If this concept works out as expected, Tesco will have the market all to itself, at least until competitors catch up

  19. A comprehensive approach to decipher biological computation to achieve next generation high-performance exascale computing.

    Energy Technology Data Exchange (ETDEWEB)

    James, Conrad D.; Schiess, Adrian B.; Howell, Jamie; Baca, Michael J.; Partridge, L. Donald; Finnegan, Patrick Sean; Wolfley, Steven L.; Dagel, Daryl James; Spahn, Olga Blum; Harper, Jason C.; Pohl, Kenneth Roy; Mickel, Patrick R.; Lohn, Andrew; Marinella, Matthew

    2013-10-01

    The human brain (volume=1200cm3) consumes 20W and is capable of performing > 10^16 operations/s. Current supercomputer technology has reached 1015 operations/s, yet it requires 1500m^3 and 3MW, giving the brain a 10^12 advantage in operations/s/W/cm^3. Thus, to reach exascale computation, two achievements are required: 1) improved understanding of computation in biological tissue, and 2) a paradigm shift towards neuromorphic computing where hardware circuits mimic properties of neural tissue. To address 1), we will interrogate corticostriatal networks in mouse brain tissue slices, specifically with regard to their frequency filtering capabilities as a function of input stimulus. To address 2), we will instantiate biological computing characteristics such as multi-bit storage into hardware devices with future computational and memory applications. Resistive memory devices will be modeled, designed, and fabricated in the MESA facility in consultation with our internal and external collaborators.

  20. Stellar performance: top honor for Tesco - new generation of mechanical muscle sells like hot cakes

    Energy Technology Data Exchange (ETDEWEB)

    Jaremko, G.

    1997-10-06

    Tesco Corporation, a Calgary-based oil field equipment supply company, was recently awarded the 1997 Canada Export Award. The award was for top performance in selling, leasing and maintaining (all in one package) a top drive unit. The unit rotates drills up from rig floors to the top of the pipe strings that drive the drill bits into the earth. There are currently some 130 Tesco machines in action despite heavy competition from industry giant Varco and others. Tesco is also developing new product lines for the rapidly developing `underbalanced drilling` market, and is testing a new concept for simultaneous drilling and casing of wells. If this concept works out as expected, Tesco will have the market all to itself, at least until competitors catch up.

  1. Performance of Different Sensors for Monitoring of the Vibration Generated during Thermosonic Non-destructive Testing

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Bu Byoung [Korea Railroad Research Institute, Uiwang (Korea, Republic of)

    2011-04-15

    Vibration monitoring is required for reliable thermosonic testing to decide whether sufficient vibration is achieved in each test for the detection of cracks. From a practical point of view, a cheaper and convenient monitoring method is better for the application to real tests. Therefore, the performance of different sensors for vibration monitoring was investigated and compared in this study to find a convenient and acceptable measurement method for thermosonics. Velocity measured by a laser vibrometer and strain provide an equivalent HI when measured at the same position. The microphone can provide a cheaper vibration monitoring device than the laser and the heating index calculated by a microphone signal shows similar characteristics to that calculated from velocity measured by the laser vibrometer. The microphone frequency response shows that it underestimates high frequency components but it is applicable to practical tests because it gives a conservative value of HI

  2. Performance analysis of a miniature turbine generator for intracorporeal energy harvesting.

    Science.gov (United States)

    Pfenniger, Alois; Vogel, Rolf; Koch, Volker M; Jonsson, Magnus

    2014-05-01

    Replacement intervals of implantable medical devices are commonly dictated by battery life. Therefore, intracorporeal energy harvesting has the potential to reduce the number of surgical interventions by extending the life cycle of active devices. Given the accumulated experience with intravascular devices such as stents, heart valves, and cardiac assist devices, the idea to harvest a small fraction of the hydraulic energy available in the cardiovascular circulation is revisited. The aim of this article is to explore the technical feasibility of harvesting 1 mW electric power using a miniature hydrodynamic turbine powered by about 1% of the cardiac output flow in a peripheral artery. To this end, numerical modelling of the fluid mechanics and experimental verification of the overall performance of a 1:1 scale friction turbine are performed in vitro. The numerical flow model is validated for a range of turbine configurations and flow conditions (up to 250 mL/min) in terms of hydromechanic efficiency; up to 15% could be achieved with the nonoptimized configurations of the study. Although this article does not entail the clinical feasibility of intravascular turbines in terms of hemocompatibility and impact on the circulatory system, the numerical model does provide first estimates of the mechanical shear forces relevant to blood trauma and platelet activation. It is concluded that the time-integrated shear stress exposure is significantly lower than in cardiac assist devices due to lower flow velocities and predominantly laminar flow. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  3. Liquid-Crystal Thermosets, a New Generation of High-Performance Liquid-Crystal Polymers

    Science.gov (United States)

    Dingemans, Theo; Weiser, Erik; Hou, Tan; Jensen, Brian; St. Clair, Terry

    2004-01-01

    One of the major challenges for NASA's next-generation reusable-launch-vehicle (RLV) program is the design of a cryogenic lightweight composite fuel tank. Potential matrix resin systems need to exhibit a low coefficient of thermal expansion (CTE), good mechanical strength, and excellent barrier properties at cryogenic temperatures under load. In addition, the resin system needs to be processable by a variety of non-autoclavable techniques, such as vacuum-bag curing, resin-transfer molding (RTM), vacuum-assisted resin-transfer molding (VaRTM), resin-film infusion (RFI), pultrusion, and advanced tow placement (ATP). To meet these requirements, the Advanced Materials and Processing Branch (AMPB) at NASA Langley Research Center developed a new family of wholly aromatic liquid-crystal oligomers that can be processed and thermally cross-linked while maintaining their liquid-crystal order. All the monomers were polymerized in the presence of a cross-linkable unit by use of an environmentally benign melt-condensation technique. This method does not require hazardous solvents, and the only side product is acetic acid. The final product can be obtained as a powder or granulate and has an infinite shelf life. The obtained oligomers melt into a nematic phase and do not exhibit isotropization temperatures greater than the temperatures of decomposition (Ti > T(sub dec)). Three aromatic formulations were designed and tested and included esters, ester-amides, and ester-imides. One of the major advantages of this invention, named LaRC-LCR or Langley Research Center-Liquid Crystal Resin, is the ability to control a variety of resin characteristics, such as melting temperature, viscosity, and the cross-link density of the final part. Depending on the formulation, oligomers can be prepared with melt viscosities in the range of 10-10,000 poise (100 rad/s), which can easily be melt-processed using a variety of composite-processing techniques. This capability provides NASA with custom

  4. Development and performance test of a system available for generating multiple extreme conditions for neutron scattering experiments

    International Nuclear Information System (INIS)

    Kawano, Shinji; Fukui, Susumu; Moriai, Atsushi; Ohtomo, Akitoshi; Ichimura, Shigeki; Onodera, Akifumi; Amita, F.; Katano, Susumu

    1998-01-01

    We have developed unique system available for controlling sample environment during the neutron scattering experiments. The system can simultaneously generate triple extreme conditions of low temperature, high magnetic field and high pressure. The system consists of: (i) a liquid-helium cryostat variable for sample temperature from 1.7 K to 200 K, (ii) a superconducting magnet providing a vertical field up to ±5 T with an antisymmetric split-coil geometry for polarized-beam experiments, and (iii) a non-magnetic piston-cylinder high-pressure cell designed with the aim of generating hydrostatic pressure up to 2.5 GPa. In the presentation, we will report the outline of the system and some results of performance tests at KURRI and JRR-3M of JAERI. (author)

  5. The utilization and performance of poly zirconium chloride (PZC) as chromatographic column for 99mTc generator

    International Nuclear Information System (INIS)

    Wan Anuar Wan Awang; Zulkifli Mohd Hashim; Saaban Kassim

    2004-01-01

    We report on the performance test of column 99m Tc generator utilizing poly zirconium chloride as an adsorbent. Natural molybdenum trioxide was irradiated for 2 hrs at a neutron flux of about 1.5 x 10 12 n/cm 2 /s. A total fourteen generators have been prepared from the experiments. Yield of 99m Tc has been 60-93% and measured 99 Mo content in eluates is 0.20-0.44 %. The adsorption efficiency of 99 Mo on PZC column is between 85 - 92 %. The flow rates from the elution are relatively very poor and take about 5 minutes to finish the elution of 1 ml saline. (author)

  6. Development and Performance Evaluation of High Temperature Concrete for Thermal Energy Storage for Solar Power Generation

    Energy Technology Data Exchange (ETDEWEB)

    Selvam, R. Panneer; Hale, Micah; Strasser, Matt

    2013-03-31

    Thermal energy can be stored by the mechanism of sensible or latent heat or heat from chemical reactions. Sensible heat is the means of storing energy by increasing the temperature of the solid or liquid. Since the concrete as media cost per kWhthermal is $1, this seems to be a very economical material to be used as a TES. This research is focused on extending the concrete TES system for higher temperatures (500 °C to 600 °C) and increasing the heat transfer performance using novel construction techniques. To store heat at high temperature special concretes are developed and tested for its performance. The storage capacity costs of the developed concrete is in the range of $0.91-$3.02/kWhthermal. Two different storage methods are investigated. In the first one heat is transported using molten slat through a stainless steel tube and heat is transported into concrete block through diffusion. The cost of the system is higher than the targeted DOE goal of $15/kWhthermal. The increase in cost of the system is due to stainless steel tube to transfer the heat from molten salt to the concrete blocks.The other method is a one-tank thermocline system in which both the hot and cold fluid occupy the same tank resulting in reduced storage tank volume. In this model, heated molten salt enters the top of the tank which contains a packed bed of quartzite rock and silica sand as the thermal energy storage (TES) medium. The single-tank storage system uses about half the salt that is required by the two-tank system for a required storage capacity. This amounts to a significant reduction in the cost of the storage system. The single tank alternative has also been proven to be cheaper than the option which uses large concrete modules with embedded heat exchangers. Using computer models optimum dimensions are determined to have an round trip efficiency of 84%. Additionally, the cost of the structured concrete thermocline configuration provides the TES

  7. Development and application of an efficient method for performing modal analysis of steam generator tubes in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Rhee, Huinam [Dept of Mechanical and Aerospace Engineering, Sunchon National University, Sunchon, 540-742 (Korea, Republic of); Boo, Myung-Hwan [Korea Hydro and Nuclear Power Company, Yuseong-Gu, Daejeon 305-343 (Korea, Republic of); Park, Chi-Yong [KEPCO Research Institute, Yuseong-Gu, Daejeon 305-380 (Korea, Republic of); Ryu, Ki-Wahn, E-mail: kwryu@chonbuk.ac.k [Department of Aerospace Engineering, Chonbuk National University, 664-14, Deogjin-Dong, Jeonju 561-756 (Korea, Republic of)

    2010-10-15

    A typical pressurized water reactor (PWR) steam generator has approximately 10,000 tubes. These tubes have different geometries, supporting conditions, and different material properties due to the non-uniform temperature distribution throughout the steam generator. Even though some tubes may have the same geometry and boundary conditions, the non-uniform distribution of coolant densities adjacent to the tubes causes them to have different added mass effects and dynamic characteristics. Therefore, for a reliable design of the steam generator, a separate modal analysis for each tube is necessary to perform the FIV (flow-induced vibration) analysis. However, the modal analysis of a tube including the finite element modeling is cumbersome and takes lots of time. And when a commercial finite element code is used, interfacing the modal analysis result, such as natural frequencies and mode shapes, with the FIV analysis procedure requires an additional significant amount of time and can possibly incur inadvertent error due to the complexity of data processing. It is therefore impossible to perform the complete FIV analysis for ten thousands of tubes when designing or maintaining a steam generator although it is necessary. Rather, to verify the safe design against the FIV, only a couple of tubes are chosen based on engineering judgment or past experience. In this paper, a computer program, PIAT-MODE, was developed which is able to perform modal analysis of all tubes of a PWR steam generator in a very efficient way. The geometries and boundary conditions of every tube were incorporated into PIAT-MODE using appropriate mathematical formulae. Material property data including the added mass effect was also included in the program. Once a specific tube is selected, the program automatically constructs the finite element model and generates the modal data very quickly. Therefore, modal analysis can be performed for every single tube in a straight way. When PIAT-MODE is coupled

  8. New performance in harmonic analysis device generation used for magnetic fields measurements

    International Nuclear Information System (INIS)

    Evesque, C.; Tkatchenko, M.

    1996-01-01

    In particle accelerator, correcting high multipole components of magnets are of high importance for quality magnet: to get a pure quadrupole to within 10 -4 , we have to know the field quality to 10 -5 through the 30. order. Our laboratory needed such a very sharp device to find small harmonic components of magnetic field. For harmonic analysis of magnetic field, we adopted the standard method, i.e. a rotating coil connected to a flux integrator. Nowadays, coils measuring azimuthal component of magnetic field are used. In order to obtain correct and accurate measurements, we were guided by two imperatives: first, optimisation of construction constraints and second, comparison of azimuthal and radial component measurements. With this background, this article describes both new technological solutions adopted and new performance obtained. We also discuss the most suitable geometric structure for the coils. We obtained a noiseless signal, a repeatability of 10 -5 and a sensitivity up to 10 -8 Weber for both types of coils. Our device is able to find and measure main component, normal and skew multipole components up to the 32. order, when simulating local defects. The magnetic axis is located within 5 μm. The central gradient is also measured and magnetic length deduced. Complementary functions of two types of coils were noticed in detecting local defects of magnetic structure. (authors)

  9. Performance of Mentik Wangi rice (Oryza sativa, L.) M2 generation from gamma ray irradiation

    Science.gov (United States)

    Yunus, A.; Parjanto; Nandariyah; Wulandari, S.

    2018-03-01

    The objective of this research is to produce Mentik Wangi rice with shorter flowering age, shorter rice stem and high yield. This research was conducted in Palur Village, Mojolaban Sub-district, Sukoharjo District, from April to August 2016. This research used descriptive method, performed by observing each individual and comparing to the control average. Observational variables included plant height, total number of tillers, number of productive tillers, panicle length, number of grain per panicle, panicle density index, 1,000 filled seed weight, seed weight of cluster, flowering age and M2 mutant selection. The results showed that there were several plants indicated mutation, there were 7 plants indicate short stem mutation with height 85 cm to 97 cm. The plants which indicated short flowering age were 5 weeks after planting up to 6 weeks after planting. The mutated plants indicating of the highest number of productive tillers which were 27 up to 36. Each component result includes total number of tillers, number of productive tillers, number of grain of panicle as well as the weight of 1000 seeds in the plant indicated some mutation that has a high level of diversity in each treatment.

  10. New performance in harmonic analysis device generation used for magnetic fields measurements

    Energy Technology Data Exchange (ETDEWEB)

    Evesque, C.; Tkatchenko, M.

    1996-12-31

    In particle accelerator, correcting high multipole components of magnets are of high importance for quality magnet: to get a pure quadrupole to within 10{sup -4}, we have to know the field quality to 10{sup -5} through the 30. order. Our laboratory needed such a very sharp device to find small harmonic components of magnetic field. For harmonic analysis of magnetic field, we adopted the standard method, i.e. a rotating coil connected to a flux integrator. Nowadays, coils measuring azimuthal component of magnetic field are used. In order to obtain correct and accurate measurements, we were guided by two imperatives: first, optimisation of construction constraints and second, comparison of azimuthal and radial component measurements. With this background, this article describes both new technological solutions adopted and new performance obtained. We also discuss the most suitable geometric structure for the coils. We obtained a noiseless signal, a repeatability of 10{sup -5} and a sensitivity up to 10{sup -8} Weber for both types of coils. Our device is able to find and measure main component, normal and skew multipole components up to the 32. order, when simulating local defects. The magnetic axis is located within 5 {mu}m. The central gradient is also measured and magnetic length deduced. Complementary functions of two types of coils were noticed in detecting local defects of magnetic structure. (authors).

  11. Orthogonal Test Analysis on Conditions Affecting Electricity Generation Performance of an Enhanced Geothermal System at Yangbajing Geothermal Field

    Directory of Open Access Journals (Sweden)

    Yuchao Zeng

    2017-12-01

    Full Text Available The main conditions affecting electricity generation performance of an enhanced geothermal system (EGS include reservoir porosity, reservoir permeability, rock heat conductivity, water production rate and injection temperature. Presently there is lack of systematic research the relative importance of the five aforementioned conditions. The orthogonal test method is a statistical approach to analyze multi-factor and multi-level influence on system performance. In this work, based on the geological data at Yangbajing geothermal field, we analyzed the five conditions affecting the electricity generation performance of EGS, and ranked the relative importance of the five factors. The results show that the order of the relative importance of the conditions on electric power is water production rate > injection temperature > reservoir porosity > rock heat conductivity > reservoir permeability; the order of the relative importance of the conditions on reservoir impedance is reservoir permeability > injection temperature > water production rate > reservoir porosity > rock heat conductivity; the order of the relative importance of the conditions on pump power is water production rate > reservoir permeability > injection temperature > reservoir porosity > rock heat conductivity, and; the order of the relative importance of the conditions on energy efficiency is water production rate > reservoir permeability > reservoir porosity > injection temperature > rock heat conductivity. The construction of an EGS reservoir should be located at a formation with higher reservoir porosity or rock heat conductivity, while the determination of reservoir permeability, water production rate and injection temperature should be based on the comprehensive target.

  12. Power generation and gaseous emissions performance of an internal combustion engine fed with blends of soybean and beef tallow biodiesel.

    Science.gov (United States)

    Schirmer, Waldir Nagel; Gauer, Mayara Ananda; Tomaz, Edson; Rodrigues, Paulo Rogério Pinto; de Souza, Samuel Nelson Melegari; Chaves, Luiz Inácio; Villetti, Lucas; Olanyk, Luciano Zart; Cabral, Alexandre Rodrigues

    2016-01-01

    This study aimed to compare the performance of an internal combustion engine fed with blends of biodiesel produced from soybean and diesel, and blends of biodiesel produced from beef tallow and diesel. Performance was evaluated in terms of power generated at low loading conditions (0.5, 1.0 and 1.5 kW) and emission of organic and inorganic pollutants. In order to analyse inorganic gases (CO, SO2 and NOx), an automatic analyser was used and the organic emissions (benzene, toluene, ethylbenzene and xylene - BTEX) were carried out using a gas chromatograph. The results indicate that the introduction of the two biodiesels in the fuel caused a reduction in CO, SO2 and BTEX emissions. In addition, the reduction was proportional to the increase in loading regime. Beef tallow biodiesels presented better results regarding emission than soybean biodiesels. The use of pure biodiesels also presented a net reduction in pollutant gas emissions without hindering the engine generator performance.

  13. Controllable Grid Interface for Testing Ancillary Service Controls and Fault Performance of Utility-Scale Wind Power Generation: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Gevorgian, Vahan; Koralewicz, Przemyslaw; Wallen, Robb; Muljadi, Eduard

    2017-02-01

    The rapid expansion of wind power has led many transmission system operators to demand modern wind power plants to comply with strict interconnection requirements. Such requirements involve various aspects of wind power plant operation, including fault ride-through and power quality performance as well as the provision of ancillary services to enhance grid reliability. During recent years, the National Renewable Energy Laboratory (NREL) of the U.S. Department of Energy has developed a new, groundbreaking testing apparatus and methodology to test and demonstrate many existing and future advanced controls for wind generation (and other renewable generation technologies) on the multimegawatt scale and medium-voltage levels. This paper describes the capabilities and control features of NREL's 7-MVA power electronic grid simulator (also called a controllable grid interface, or CGI) that enables testing many active and reactive power control features of modern wind turbine generators -- including inertial response, primary and secondary frequency responses, and voltage regulation -- under a controlled, medium-voltage grid environment. In particular, this paper focuses on the specifics of testing the balanced and unbalanced fault ride-through characteristics of wind turbine generators under simulated strong and weak medium-voltage grid conditions. In addition, this paper provides insights on the power hardware-in-the-loop feature implemented in the CGI to emulate (in real time) the conditions that might exist in various types of electric power systems under normal operations and/or contingency scenarios. Using actual test examples and simulation results, this paper describes the value of CGI as an ultimate modeling validation tool for all types of 'grid-friendly' controls by wind generation.

  14. Low Cost High Performance Generator Technology Program. Volume 4. Mission application study

    International Nuclear Information System (INIS)

    1975-07-01

    Results of initial efforts to investigate application of selenide thermoelectric RTG's to specific missions as well as an indication of development requirements to enable satisfaction of emerging RTG performance criteria are presented. Potential mission applications in DoD such as SURVSATCOM, Advance Defense Support Program, Laser Communication Satellite, Satellite Data System, Global Positioning Satellite, Deep Space Surveillance Satellite, and Unmanned Free Swimming Submersible illustrate power requirements in the range of 500 to 1000 W. In contrast, the NASA applications require lower power ranging from 50 W for outer planetary atmospheric probes to about 200 W for spacecraft flights to Jupiter and other outer planets. The launch dates for most of these prospective missions is circa 1980, a requirement roughly compatible with selenide thermoelectric and heat source technology development. A discussion of safety criteria is included to give emphasis to the requirements for heat source design. In addition, the observation is made that the potential accident environments of all launch vehicles are similar so that a reasonable composite set of design specifications may be derived to satisfy almost all applications. Details of the LCHPG application potential is afforded by three designs: an 80 W RTG using improved selenide thermoelectric material, a 55 to 65 W LCHPG using current and improved selenide materials, and the final 500 W LCHPG as reported in Volume 2. The final results of the LCHPG design study have shown that in general, all missions can expect an LCHPG design which yields 10 percent efficiency at 3 W/lb with the current standard selenide thermoelectric materials, with growth potential to 14 percent at greater than 4 W/lb in the mid 1980's time frame

  15. Fission-gas release in fuel performing to extended burnups in Ontario Hydro nuclear generating stations

    International Nuclear Information System (INIS)

    Floyd, M.R.; Novak, J.; Truant, P.T.

    1992-06-01

    The average discharge burnup of CANDU fuel is about 200 MWh/kgU. A significant number of 37-element bundles have achieved burnups in excess of 400 MWh/kgU. Some of these bundles have experienced failures related to their extended operation. To date, hot-cell examinations have been performed on fuel elements from nine 37-element bundles irradiated in Bruce NGS-A that have burnups in the range of 300-800 MWh/kgU. 1 Most of these have declining power histories from peak powers of up to 59 kW/m. Fission-gas releases of up to 26% have been observed and exhibit a strong dependence on fuel power. This obscures any dependence on burnup. The extent of fission-gas release at extended burnups was not predicted by low-burnup code extrapolations. This is attributed primarily to a reduction in fuel thermal conductivity which results in elevated operating temperatures. Reduced conductivity is due, at least in part, to the buildup of fission products in the fuel matrix. Some evidence of hyperstoichiometry exists, although this needs to be further investigated along with any possible relation to CANLUB graphite coating behaviour and sheath oxidation. Residual tensile sheath strains of up to 2% have been observed and can be correlated with fuel power/fission-gas release. SCC 2 -related defects have been observed in the sheath and endcaps of elements from bundles experiencing declining power histories to burnups in excess of 500 MWh/kgU. This indicates that the current recommended burnup limit of 450 MWh/kgU is justified. SCC-related defects have also been observed in ramped bundles having burnups < 450 MWh/kgU. Hence, additional guidelines are in place for power ramping extended-burnup fuel

  16. AREVA's toolbox for long-term best performance and reliable operation of nuclear steam generators

    International Nuclear Information System (INIS)

    Drexler, Andreas; Weiss, Steffen; Caris, Neil; Stiepani, Christoph

    2015-01-01

    Long-term integrity and high performance of major plant systems and components are of uppermost importance for the successful operation of any power plant. AREVA's experience gathered with water-steam cycle chemistry treatments in more than 40 years yields the conclusion: Accumulation of corrosion products in SGs may result in local overheating and enrichment of impurities up to critical levels. This can lead to several degradation phenomena of the structural materials of the SGs. Therefore, minimization of corrosion product generation and prevention of deposit accumulation is required. The objective of AREVA's asset management program is to support operators by minimizing corrosion damage and performance losses of water-steam cycle systems and components and thereby to maximize the availability and economic performance of the plant. Such asset management program is in principle a closed cycle process. It is based on control, corrective and preventive measures. The objective of control measure is deriving a widespread assessment of the corrosion status of the steam-water cycle which yields to weak points and identifying the best suited corrective and/or preventive measures. In the subsequent steps appropriate measures which improve the current status or counteract on identified issues are identified and applied. Corrective measures, likes mechanical and/or chemical cleaning are targeting the minimization of negative influence on plant performance caused by corrosion in the steam-water cycle. Complementary to corrective measures are preventive ones, like optimization of pH strategy and AREVA's FFA technology could by applied. They are focusing on the origin of corrosion product generation. AREVA is offering a toolbox for long-term best performance and reliable operation of NPPs. (author)

  17. Performance and Potential Study of 10kW Wind Turbine Generator for 6 Cities in Malaysia

    Directory of Open Access Journals (Sweden)

    Mustaqimah Mustaqimah

    2013-04-01

    Full Text Available ABSTRACT. This study presents an analysis of the optimization by using HOMER software and financial viability of 10 kW wind turbine generator (WTG through grid connected system for six different locations in Malaysia (Mersing, Kuching, K.Trengganu, Kudat, Melaka and Labuan. Assessment criteria comprised Total Net Present Cost (TNPC, and Cost of Energy ( COE . The HOMER ( National Renewable Energy laboratory, US was utilized as the assessment tool with modeling performed with hourly load data input from six cities in Malaysia. The results demonstrate that WTG has the potential to supply significant power for small scale load in conjunction with the grid-electricity supply. Optimization modeling demonstrated that the TNPC for grid connected configuration is Mersing for the lowest TNPC among the other cities which is TNPC recorded at $ -28,436 and initial cost is about $ 20,000. This mean wind grid system in Mersing is very benefit be built and reduction in greenhouse gas emission of 9,452 kg/yr. Optimization modeling also showed that Mersing is the only one among other city had showed a high potential of WTG which produced energy at 85,326 kWh/yr and purchase grid only at 4,082 kWh/year. Kajian Kinerja dan Potensi Generator Turbin Angin 10kW untuk 6 kota di Malaysia ABSTRAK. Penelitian ini menyajikan analisis optimasi dengan menggunakan software HOMER dan kesesuaian biaya untuk generator turbin angin (wind turbine generator=WTG 10 kW sistem grid untuk enam lokasi yang berbeda di Malaysia (Mersing, Kuching, K.Trengganu, Kudat, Melaka dan Labuan. Kriteria penilaian terdiri Total Net Present Cost (TNPC dan Cost of Energy (COE. software HOMER (National Renewable Energy laboratory, US digunakan sebagai pemodelan dengan memasukkan data beban daya per jam dari enam kota tersebut. Hasil penelitian menunjukkan bahwa generator turbin angin (WTG memiliki potensi untuk memasok daya yang signifikan untuk beban kecil dalam hubungannya dengan pasokan grid

  18. Feasibility Study of Economics and Performance of Wind Turbine Generators at the Newport Indiana Chemical Depot Site

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, Joseph Owen [National Renewable Energy Lab. (NREL), Golden, CO (United States); Mosey, Gail [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2013-11-01

    The U.S. Environmental Protection Agency (EPA), in accordance with the RE-Powering America's Land initiative, selected the Newport Indiana Chemical Depot site in Newport, Indiana, for a feasibility study of renewable energy production. The National Renewable Energy Laboratory (NREL) was contacted to provide technical assistance for this project. The purpose of this report is to assess the sitefor possible wind turbine electrical generator installation and estimate the cost, performance, and site impacts of different wind energy options. In addition, the report recommends financing options that could assist in the implementation of a wind system at the site.

  19. Methodology and Toolset for Model Verification, Hardware/Software co-simulation, Performance Optimisation and Customisable Source-code generation

    DEFF Research Database (Denmark)

    Berger, Michael Stübert; Soler, José; Yu, Hao

    2013-01-01

    The MODUS project aims to provide a pragmatic and viable solution that will allow SMEs to substantially improve their positioning in the embedded-systems development market. The MODUS tool will provide a model verification and Hardware/Software co-simulation tool (TRIAL) and a performance...... optimisation and customisable source-code generation tool (TUNE). The concept is depicted in automated modelling and optimisation of embedded-systems development. The tool will enable model verification by guiding the selection of existing open-source model verification engines, based on the automated analysis...

  20. History of large scale maintenance operations performed by EDF on the steam generators of its nuclear power plants

    International Nuclear Information System (INIS)

    2010-01-01

    After a first part which describes the role of steam generators in nuclear reactors, highlights their importance for the reactor safety, and briefly presents their maintenance, this report describes the new types of degradation which have been observed, and their processing. Thus, it describes the clogging on cracked tubes, comments its impact on safety, describes the available control means, and discusses the use of chemical cleaning and the on-going work on this topic. It discusses the risk of fatigue cracking of tubes in abnormal support position. It comments the holding in position of stoppers used during maintenance. It describes and discusses the corrosion phenomena, and the performed and requested corrective actions