WorldWideScience

Sample records for generating power stations

  1. Nuclear power generation modern power station practice

    CERN Document Server

    1971-01-01

    Nuclear Power Generation focuses on the use of nuclear reactors as heat sources for electricity generation. This volume explains how nuclear energy can be harnessed to produce power by discussing the fundamental physical facts and the properties of matter underlying the operation of a reactor. This book is comprised of five chapters and opens with an overview of nuclear physics, first by considering the structure of matter and basic physical concepts such as atomic structure and nuclear reactions. The second chapter deals with the requirements of a reactor as a heat source, along with the diff

  2. A Renewably Powered Hydrogen Generation and Fueling Station Community Project

    Science.gov (United States)

    Lyons, Valerie J.; Sekura, Linda S.; Prokopius, Paul; Theirl, Susan

    2009-01-01

    The proposed project goal is to encourage the use of renewable energy and clean fuel technologies for transportation and other applications while generating economic development. This can be done by creating an incubator for collaborators, and creating a manufacturing hub for the energy economy of the future by training both white- and blue-collar workers for the new energy economy. Hydrogen electrolyzer fueling stations could be mass-produced, shipped and installed in collaboration with renewable energy power stations, or installed connected to the grid with renewable power added later.

  3. GHG PSD Permit: Cheyenne Light, Fuel & Power / Black Hills Power, Inc. – Cheyenne Prairie Generating Station

    Science.gov (United States)

    This page contains the final PSD permit for the Cheyenne Light, Fuel & Power / Black Hills Power, Inc. Cheyenne Prairie Generating Station, located in Laramie, Wyoming, and operated by Black Hills Service Company.

  4. GT power generation stations in noise sensitive areas

    Energy Technology Data Exchange (ETDEWEB)

    Gambino, V.; Richarz, W. [Aercoustics Engineering Ltd., Toronto, ON (Canada)

    2009-07-01

    Noise impact must be quantified during the initial planning phase of a power plant because it may play a part in potential land acquisitions and system configuration. Noise control measures are required at gas turbine power generating stations located in noise sensitive areas. This study used graphs to illustrate that assigning noise control priorities may be complicated. Noise ranking with respect to the contribution of sound power was plotted against the ranking with respect to the contribution of sound pressure levels. Noise impact estimates based on a simplistic source model tend to over-predict the actual sound levels. More detailed emission models are needed during the initial planning phase to help assess the cost of any noise controls. The methodology described in this paper was developed to help the developer during the planning phases to determine the relative contribution of various components to the overall sound and to mitigate excessive noise. 4 tabs., 7 figs.

  5. Developing the concept of maintenance and repairs in projects of power units for new-generation nuclear power stations

    Science.gov (United States)

    Gurinovich, V. D.; Yanchenko, Yu. A.

    2012-05-01

    Results from conceptual elaboration of individual requirements for the system of maintenance and repairs that must be implemented in the projects of new-generation nuclear power stations are presented taking as an example the power unit project for a nuclear power station equipped with a standard optimized VVER reactor with enhanced information support (the so-called VVER TOI reactor). Implementation of these concepts will help to achieve competitiveness of such nuclear power stations in the domestic and international markets.

  6. Gas-turbine expander power generating systems for internal needs of compressor stations of gas-main pipelines

    Science.gov (United States)

    Shimanov, A. A.; Biryuk, V. V.; Sheludko, L. P.; Shabanov, K. Yu.

    2017-08-01

    In the framework of this paper, there have been analyzed power station building methods to construct a power station for utilities for gas-main pipelines compressor stations. The application efficiency of turbo expanders in them to expand the power gas of compressor stations' gas compressor units has been shown. New schemes for gas-turbine expander power generating systems have been proposed.

  7. Electric Power Plants and Generation Stations, KernRiver, Published in 2007, Millard County.

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — This Electric Power Plants and Generation Stations dataset, was produced all or in part from Other information as of 2007. It is described as 'KernRiver'. Data by...

  8. Development of an HTS hydroelectric power generator for the hirschaid power station

    Science.gov (United States)

    Fair, Ruben; Lewis, Clive; Eugene, Joseph; Ingles, Martin

    2010-06-01

    This paper describes the development and manufacture of a 1.7MW, 5.25kV, 28pole, 214rpm hydroelectric power generator consisting of superconducting HTS field coils and a conventional stator. The generator is to be installed at a hydro power station in Hirschaid, Germany and is intended to be a technology demonstrator for the practical application of superconducting technology for sustainable and renewable power generation. The generator is intended to replace and uprate an existing conventional generator and will be connected directly to the German grid. The HTS field winding uses Bi-2223 tape conductor cooled to about 30K using high pressure helium gas which is transferred from static cryocoolers to the rotor via a bespoke rotating coupling. The coils are insulated with multi-layer insulation and positioned over laminated iron rotor poles which are at room temperature. The rotor is enclosed within a vacuum chamber and the complete assembly rotates at 214rpm. The challenges have been significant but have allowed Converteam to develop key technology building blocks which can be applied to future HTS related projects. The design challenges, electromagnetic, mechanical and thermal tests and results are presented and discussed together with applied solutions.

  9. Development of an HTS hydroelectric power generator for the hirschaid power station

    Energy Technology Data Exchange (ETDEWEB)

    Fair, Ruben; Lewis, Clive; Eugene, Joseph; Ingles, Martin, E-mail: ruben.fair@converteam.co [Advanced Technology Group, Converteam, Rugby, CV21 1BD (United Kingdom)

    2010-06-01

    This paper describes the development and manufacture of a 1.7MW, 5.25kV, 28pole, 214rpm hydroelectric power generator consisting of superconducting HTS field coils and a conventional stator. The generator is to be installed at a hydro power station in Hirschaid, Germany and is intended to be a technology demonstrator for the practical application of superconducting technology for sustainable and renewable power generation. The generator is intended to replace and uprate an existing conventional generator and will be connected directly to the German grid. The HTS field winding uses Bi-2223 tape conductor cooled to about 30K using high pressure helium gas which is transferred from static cryocoolers to the rotor via a bespoke rotating coupling. The coils are insulated with multi-layer insulation and positioned over laminated iron rotor poles which are at room temperature. The rotor is enclosed within a vacuum chamber and the complete assembly rotates at 214rpm. The challenges have been significant but have allowed Converteam to develop key technology building blocks which can be applied to future HTS related projects. The design challenges, electromagnetic, mechanical and thermal tests and results are presented and discussed together with applied solutions.

  10. 75 FR 42790 - Exelon Generation Company, LLC; Clinton Power Station; Environmental Assessment and Finding of No...

    Science.gov (United States)

    2010-07-22

    ... COMMISSION Exelon Generation Company, LLC; Clinton Power Station; Environmental Assessment and Finding of No...-62, issued to Exelon Generation Company, LLC (the licensee), for operation of the Clinton Power... have access to ADAMS or who encounter problems in accessing the documents located in ADAMS...

  11. Using MapReduce to Improve the Power Generation of the International Space Station

    Science.gov (United States)

    Marchetto, William R., II

    The International Space Station (ISS) spends approximately 98% of its time in orbits that experience Earth eclipse. Since the station's solar arrays produce no power when in Earth's shadow, the total power generated decreases substantially, lowering the power budget available to experimental payloads. Therefore, increasing the power output during these eclipsed orbits would be of great benefit to the space station's scientific endeavors. The ISS's current solar array configuration tracks the Sun throughout each orbit, keeping each of its 16 solar panels perpendicular to the Sun at all times. While this is the optimal orientation for solar panels with unobstructed views of the Sun, the space station's solar arrays experience shadowing from the spacecraft's structure as well as from the other solar panels. Deviating from the Sun-tracking scheme at strategic points in certain orbits can provide an increase in power output. The goal of this research was to provide a programmatic solution that increases the power generation capabilities of the ISS in orbits experiencing Earth-eclipse without requiring any physical modifications to the space station's structure. To achieve this goal, a simulator was developed to model the ISS-Earth-Sun environment and calculate the power output of the station's solar arrays based on each panel's orientation and shadowing. Many combinations of array configurations were analyzed, taking into account the physical constraints of the gimbals responsible for rotating the solar panels. The power output of the ISS was improved for the subset of Earth-eclipsed orbits that experience a high degree of shadowing from the station's structure, resulting in an average energy increase of 1.08 kWh per orbit. The power gains were achieved by quickly rotating the solar arrays through the points in each orbit that experienced the highest degree of shadowing.

  12. Central station applications planning activities and supporting studies. [application of photovoltaic technology to power generation plants

    Science.gov (United States)

    Leonard, S. L.; Siegel, B.

    1980-01-01

    The application of photovoltaic technology in central station (utility) power generation plants is considered. A program of data collection and analysis designed to provide additional information about the subset of the utility market that was identified as the initial target for photovoltaic penetration, the oil-dependent utilities (especially muncipals) of the U.S. Sunbelt, is described along with a series of interviews designed to ascertain utility industry opinions about the National Photovoltaic Program as it relates to central station applications.

  13. On the possibility of generation of cold and additional electric energy at thermal power stations

    Science.gov (United States)

    Klimenko, A. V.; Agababov, V. S.; Borisova, P. N.

    2017-06-01

    A layout of a cogeneration plant for centralized supply of the users with electricity and cold (ECCG plant) is presented. The basic components of the plant are an expander-generator unit (EGU) and a vapor-compression thermotransformer (VCTT). At the natural-gas-pressure-reducing stations, viz., gas-distribution stations and gas-control units, the plant is connected in parallel to a throttler and replaces the latter completely or partially. The plant operates using only the energy of the natural gas flow without burning the gas; therefore, it can be classified as a fuelless installation. The authors compare the thermodynamic efficiencies of a centralized cold supply system based on the proposed plant integrated into the thermal power station scheme and a decentralized cold supply system in which the cold is generated by electrically driven vapor-compression thermotransformers installed on the user's premises. To perform comparative analysis, the exergy efficiency was taken as the criterion since in one of the systems under investigation the electricity and the cold are generated, which are energies of different kinds. It is shown that the thermodynamic efficiency of the power supply using the proposed plant proves to be higher within the entire range of the parameters under consideration. The article presents the results of investigating the impact of the gas heating temperature upstream from the expander on the electric power of the plant, its total cooling capacity, and the cooling capacities of the heat exchangers installed downstream from the EGU and the evaporator of the VCTT. The results of calculations are discussed that show that the cold generated at the gas-control unit of a powerful thermal power station can be used for the centralized supply of the cold to the ventilation and conditioning systems of both the buildings of the power station and the neighboring dwelling houses, schools, and public facilities during the summer season.

  14. Generating power stations and optimization energetic of processes; Centrales generadoras y optimacion energetica de procesos

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez Ramirez, Ranulfo; Fernandez Montiel, Manuel Francisco [Instituto de Investigaciones Electricas, Temixco, Morelos (Mexico)

    1999-07-01

    Some recent experiences of the Management of Thermal Processes of the Instituto de Investigaciones Electricas (IIE) related to the works on generating power stations of electricity, plants of cogeneration and energy saving are presented. [Spanish] Se presentan algunas experiencias recientes de la Gerencia de Procesos Termicos del Instituto de Investigaciones Electricas (IIE) relacionadas con los trabajos sobre centrales generadoras de electricidad, plantas de cogeneracion y ahorro de energia.

  15. Models for the transient stability of conventional power generating stations connected to low inertia systems

    Science.gov (United States)

    Zarifakis, Marios; Coffey, William T.; Kalmykov, Yuri P.; Titov, Sergei V.

    2017-06-01

    An ever-increasing requirement to integrate greater amounts of electrical energy from renewable sources especially from wind turbines and solar photo-voltaic installations exists and recent experience in the island of Ireland demonstrates that this requirement influences the behaviour of conventional generating stations. One observation is the change in the electrical power output of synchronous generators following a transient disturbance especially their oscillatory behaviour accompanied by similar oscillatory behaviour of the grid frequency, both becoming more pronounced with reducing grid inertia. This behaviour cannot be reproduced with existing mathematical models indicating that an understanding of the behaviour of synchronous generators, subjected to various disturbances especially in a system with low inertia requires a new modelling technique. Thus two models of a generating station based on a double pendulum described by a system of coupled nonlinear differential equations and suitable for analysis of its stability corresponding to infinite or finite grid inertia are presented. Formal analytic solutions of the equations of motion are given and compared with numerical solutions. In particular the new finite grid model will allow one to identify limitations to the operational range of the synchronous generators used in conventional power generation and also to identify limits, such as the allowable Rate of Change of Frequency which is currently set to ± 0.5 Hz/s and is a major factor in describing the volatility of a grid as well as identifying requirements to the total inertia necessary, which is currently provided by conventional power generators only, thus allowing one to maximise the usage of grid connected non-synchronous generators, e.g., wind turbines and solar photo-voltaic installations.

  16. Safety research of insulating materials of cable for nuclear power generating station

    Science.gov (United States)

    Lee, C. K.; Choi, J. H.; Kong, Y. K.; Chang, H. S.

    1988-01-01

    The polymers PE, EPR, PVC, Neoprene, CSP, CLPE, EP and other similar substances are frequently used as insulation and protective covering for cables used in nuclear power generating stations. In order to test these materials for flame retardation, environmental resistance, and cable specifications, they were given the cable normal test, flame test, chemical tests, and subjected to design analysis and loss of coolant accident tests. Material was collected on spark tests and actual experience standards were established through these contributions and technology was accumulated.

  17. Electric Power Plants and Generation Stations, Published in 1992, 1:1200 (1in=100ft) scale, County of Lexington.

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — This Electric Power Plants and Generation Stations dataset, published at 1:1200 (1in=100ft) scale, was produced all or in part from Orthoimagery information as of...

  18. Assesment of Carbon Credits for Power Generation Systems at GSM Base Station Site

    OpenAIRE

    Ani, Vincent Anayochukwu; Ani, Emmanuel Onyeka

    2016-01-01

    Electricity production is often a source of CO2 emissions, for instance when fossil fuel is combusted in power plants. Therefore the root cause of pollution coming from telecommunication industry is the source of energy (diesel genset) the network operators used in running their Base station sites. Energy consumption of using diesel to power base station by telecom networks is a contributor to global greenhouse gas (GHG) emissions. This paper presents the comparative carbon credits of hybrid ...

  19. Environmental radiological studies downstream from Rancho Seco Nuclear Power Generating Station

    Energy Technology Data Exchange (ETDEWEB)

    Noshkin, V.E.; Wong, K.M.; Eagle, R.J.; Dawson, J.W.; Brunk, J.L.; Jokela, T.A.

    1985-03-22

    This report summarizes the information compiled in 1984 while assessing the environmental impact of radionuclides in aquatic releases from the Rancho Seco Nuclear Power Generating Station. Gamma-emitting radionuclides discharged since 1981 are found in many of the dietary components derived from the creeks receiving the effluent wastewater. Some soils and crops are found to contain radionuclides that originate from the contaminated water that was transferred to land during the irrigation season. /sup 134/Cs and /sup 137/Cs are the primary gamma-emitting radionuclides detected in the edible flesh of fish from the creeks. Concentrations in the flesh of fish decreased exponentially with distance from the plant. No significant differences in the /sup 137/Cs activity were found between male and female fish of equal size, but concentrations may vary in fish of different size, with the season and diet. 21% of the total /sup 137/Cs and /sup 134/Cs discharged between 1981 and 1984 is associated with the creek sediments to a distance of 27 km from the plant. Fractions of the missing inventory have been transferred to land during the irrigation season or to downstream regions more distant than 27 km from the plant. The radiocesium content of the sediments in 1984 decreased significantly in a downstream direction, much in the same manner as concentrations decreased in fish. Radioactivity originating from the plant was not above detection limits in any terrestrial food item sampled beyond 6.5 km from the plant. Based on the usage factors provided by individuals interviewed in a 1984 survey, the fish and aquatic-organism ingestion pathway contributed the largest radiological dose to humans utilizing products contaminated with the radionuclides in the liquid wastes discharged from the Rancho Seco Nuclear Power Generating Station in 1984.

  20. Electric Power Plants and Generation Stations, Power_plants, Published in 2007, 1:600 (1in=50ft) scale, Buffalo County.

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — This Electric Power Plants and Generation Stations dataset, published at 1:600 (1in=50ft) scale, was produced all or in part from Orthoimagery information as of...

  1. Package power stations for export

    Energy Technology Data Exchange (ETDEWEB)

    1985-01-01

    The cheap and efficient generation of power is an essential requirement for the success and prosperity of any community and is especially important to third world countries. It is therefore logical that the more technologically advanced nations should seek to produce power stations for the developing countries. Power plant can now be designed into a packaged form that may be readily exported and commissioned. This valuable and interesting collection of papers were originally presented at a seminar organised by the Power Industries Division of the Institution of Mechanical Engineers. Topics considered include the developing world market for packaged power stations using indigenous fuels; multi-fuel systems for power generation; packaging, modularisation, and containerisation of equipment for power boilers for export; compact coal-fired industrial plant; rural woodburning power stations; biomass gasification based power generation technology and potential; gas fed reciprocating engine development; packaged heavy duty gas turbines for power generation; and criteria for assessing the appropriateness of package power technologies in developing countries.

  2. Fundamental assumptions for development of small water power stations and resulting indications for standarization of their generating sets

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, M.

    1983-01-01

    According to the criterion of simple technical construction and no regular personnel, the concept of Small Water Power Stations (SWPS) covers power stations with output capacity less than 5 MW. It follows that for economical reasons these plants should: make use of so far existing dams with total head greater than or equal to 3 m, and have simple technical solutions (1 generating set with high rotating speed and no high voltage switchboard). It is assumed that SWPS will consist mostly of flow power plants capable to operate in their own network. It is suggested that 950 SWPS with Kaplan turbines in concrete chambers or vertical and horizontal pipe turbines (H greater than or equal to 20 m) and 70 power stations with Francis turbines (H > 20 m) should be put in operation by 2000. Some results of a review, carried out recently in Poland, of structures suitable for installing small water power stations are presented. Also, some of the most important foreign companies manufacturing water turbines of small capacity are specified.

  3. Stanwell power station project

    Energy Technology Data Exchange (ETDEWEB)

    Mills, David R; J Dey, Christopher [University of Sidney, Sidney (Australia); Morrison, Graham L [University of New South Wales, Sidney (Australia)

    2000-07-01

    This paper describes the Compact Linear Fresnel Reflector (CLFR) being developed for installation at the Stanwell power station in Queensland Australia. Stanwell Corporation Limited (SCL). Solahart International, Solsearch Pty. Ltd. And the universities of Sidney and New South Wales are cooperating in the project, and this first plant being partly funded by the Australian Greenhouse Office. The solar plant will be attached to a 1440 MW(e) coal fired plant. The 17000 m{sup 2} array will be the largest array in Australia, producing a peak of 13 MW of thermal energy which will offset the use of coal in the generation of electricity. It will use direct steam generation and will feed either steam or hot water at 265 Celsius degrees directly into the power station preheating cycle. The CLFR system, first developed by the University of Sidney and Solsearch Pty. Ltd., is simple and offers small reflector size, low structural cost, fixed receiver geometry. Initial installed plant costs are approximately US$1000 per kWe, but this includes the effect of high up-front design costs and the cost should drop substantially in the second and subsequent plants. [Spanish] Proyecto de la Planta Electrica Stanwell este articulo describe el Reflector Lineal Compacto Fresnel (CLFR, siglas en ingles) que se esta desarrollando para la instalacion de la planta electrica Stanwell en Queensland, Australia. La Corporacion Stanwell Limited (SCL), Solahart International, Solsearch Pty. Ltd., las universidades de Sidney y de New South Wales estan cooperando en este proyecto, y esta primera planta esta parcialmente auspiciada por la Australian Greenhouse Office. La planta solar sera anexa a una planta de carbon de 1440 MW(e). Este arreglo de 17000 m{sup 2} sera el mayor en Australia y producira un maximo de 13 MW en energia termica la cual contrarrestara el uso del carbon en la generacion de electricidad. Utilizara generacion con vapor directo y alimentara ya sea vapor o agua caliente a 265 grados

  4. Characterization of Fly Ash Generated from Matla Power Station in Mpumalanga, South Africa

    Directory of Open Access Journals (Sweden)

    Olushola S. Ayanda

    2012-01-01

    Full Text Available In this study, fly ash was obtained from Matla power station and the physicochemical properties investigated. The fly ash was characterized by x-ray fluorescence, x-ray diffraction, scanning electron microscopy, and inductively coupled plasma mass spectrometry. Surface area, particle size, ash and carbon contents, pH, and point of zero charge were also measured. The results showed that the fly ash is alkaline and consists mainly of mullite (Al6Si2O13 and quartz (SiO2. Highly toxic metals As, Sb, Cd, Cr, and Pb as well as metals that are essential to health in trace amounts were also present. The storage and disposal of coal fly ash can thus lead to the release of leached metals into soils, surface and ground waters, find way into the ecological systems and then cause harmful effect to man and its environments.

  5. Space Station Power Generation in Support of the Beta Gimbal Anomaly Resolution

    Science.gov (United States)

    Delleur, Ann M.; Propp, Timothy W.

    2003-01-01

    The International Space Station (ISS) is the largest and most complex spacecraft ever assembled and operated in orbit. The first U.S. photovoltaic (PV) module, containing two solar arrays, was launched, installed, and activated in early December 2000. After the first week of continuously rotating the U.S. solar arrays, engineering personnel in the ISS Mission Evaluation Room (MER) observed higher than expected electrical currents on the drive motor in one of the Beta Gimbal Assemblies (BGA), the mechanism used to maneuver a U.S. solar array. The magnitude of the motor currents continued to increase over time on both BGA's, creating concerns about the ability of the gimbals to continue pointing the solar arrays towards the sun, a function critical for continued assembly of the ISS. A number of engineering disciplines convened in May 2001 to address this on-orbit hardware anomaly. This paper reviews the ISS electrical power system (EPS) analyses performed to develop viable operational workarounds that would minimize BGA use while maintaining sufficient solar array power to continue assembly of the ISS. Additionally, EPS analyses performed in support of on-orbit BGA troubleshooting exercises is reviewed. EPS capability analyses were performed using SPACE, a computer code developed by NASA Glenn Research Center (GRC) for the ISS program office.

  6. Electric Power Plants and Generation Stations, Power Plants mapped and maintained by PR Power Authority, Published in 2009, 1:1200 (1in=100ft) scale, Office of Management and Budget.

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — This Electric Power Plants and Generation Stations dataset, published at 1:1200 (1in=100ft) scale, was produced all or in part from Field Observation information as...

  7. Electric Power Plants and Generation Stations, Power Plants - is a seperate layer, however, we have them included in local building layer as well, Published in 2010, 1:2400 (1in=200ft) scale, Effingham County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Electric Power Plants and Generation Stations dataset current as of 2010. Power Plants - is a seperate layer, however, we have them included in local building layer...

  8. case study of afam power station

    African Journals Online (AJOL)

    NIJOTECH

    checking of emergency failure of components or .... 1, 2002. Madueme. 87. Table 7: History of Afam generating plans from 1962 to 1997 ... was no maintenance management section in the power station ... Training School, 1998. 5. Clifton, R.N. ...

  9. Woody biomass-based bioenergy development at the Atikokan Power Generating Station: Local perceptions and public opinions

    Science.gov (United States)

    Baten, Cassia Sanzida

    To tackle climate change, reduce air pollution and promote development of renewable energy, the Ontario government is investing in the conversion of the coal-based Atikokan Power Generating Station (APGS) in Atikokan, Ontario, to woody biomass feedstock. This research offers one of the first looks at the perspectives of different individuals and groups on converting woody biomass to energy. Using a combination of study instruments which include literature review, surveys, interviews with key informants, semi-structured interviews, and focus group discussions, this dissertation uses qualitative research to provide a picture of the public's opinions and attitudes towards the APGS biomass energy development. Given Ontario's huge and sustainably managed forest resource, woody biomass is expected to be a major component of renewable energy production in Ontario. The move towards renewable energy that replaces fossil fuels with woody biomass will have considerable socio-economic implications for local and First Nation communities living in and around the bioenergy power generating station. Findings indicate that there is wide support for biomass utilization at the APGS by local people, especially since the project would create sustainable employment. The connection of woody biomass-based energy generation and rural community development provides opportunities and challenges for Atikokan's economic development. Respondents identified economic, environmental and social barriers to biomass utilization, and emphasized trust and transparency as key elements in the successful implementation of the APGS project. As demand for woody biomass-based energy increases, special attention will be needed to ensure and maintain the social, economic and environmental sustainability of biomass use at the APGS. In this research, respondents' views about biomass utilization for energy mainly focused on forest-related issues rather than energy. In Atikokan much of the project's social

  10. Electric Power Plants and Generation Stations, Power Plants - is a seperate layer, however, we have them included in local building layer as well, Published in 2010, 1:2400 (1in=200ft) scale, Effingham County Board Of Commissioners.

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — This Electric Power Plants and Generation Stations dataset, published at 1:2400 (1in=200ft) scale, was produced all or in part from Orthoimagery information as of...

  11. Distributed power generation using microturbines

    CSIR Research Space (South Africa)

    Szewczuk, S

    2008-11-01

    Full Text Available At present, the bulk of the world is electricity is generated in central power stations. This approach, one of `economy of size generates electricity in large power stations and delivers it to load centres via an extensive network of transmission...

  12. 76 FR 29277 - Exelon Generation Company, LLC; Peach Bottom Atomic Power Station Unit Nos. 2 and 3...

    Science.gov (United States)

    2011-05-20

    ... From the Federal Register Online via the Government Publishing Office NUCLEAR REGULATORY... Assessment and Finding of No Significant Impact The U.S. Nuclear Regulatory Commission (NRC) is considering... waste (LLRW), from Exelon's Limerick Generating Station, Units 1 and 2 (LGS). The LLRW will be stored in...

  13. Development of elements of the condition monitoring system of turbo generators of thermal power stations and nuclear power plants

    Science.gov (United States)

    Kumenko, A. I.; Kostyukov, V. N.; Kuz'minykh, N. Yu.; Boichenko, S. N.; Timin, A. V.

    2017-08-01

    The rationale is given for the improvement of the regulatory framework for the use of shaft sensors for the in-service condition monitoring of turbo generators and the development of control systems of shaft surfacing and misalignments of supports. A modern concept and a set of methods are proposed for the condition monitoring of the "shaft line-thrust bearing oil film-turbo generator supports" system elements based on the domestic COMPACS® technology. The system raw data are design, technology, installation, and operating parameters of the turbo generator as well as measured parameters of the absolute vibration of supports and mechanical quantities, relative displacements and relative vibration of the rotor teeth in accordance with GOST R 55263-2012. The precalculated shaft line assembly line in the cold state, the nominal parameters of rotor teeth positions on the dynamic equilibrium curve, the static and dynamic characteristics of the oil film of thrust bearings, and the shaft line stiffness matrix of unit support displacements have been introduced into the system. Using the COMPACS-T system, it is planned to measure positions and oscillations of rotor teeth, to count corresponding static and dynamic characteristics of the oil film, and the static and dynamic loads in the supports in real time. Using the obtained data, the system must determine the misalignments of supports and corrective alignments of rotors of coupling halves, voltages in rotor teeth, welds, and bolts of the coupling halves, and provide automatic conclusion if condition monitoring parameters correspond to standard values. A part of the methodological support for the proposed system is presented, including methods for determining static reactions of supports under load, the method for determining shaft line stiffness matrices, and the method for solving the inverse problem, i.e., the determination of the misalignments of the supports by measurements of rotor teeth relative positions in bearing

  14. Power electronic applications for Space Station Freedom

    Science.gov (United States)

    Pickrell, Roy L.; Lazbin, Igor

    1990-01-01

    NASA plans to orbit a permanently manned space station in the late 1990s, which requires development and assembly of a photovoltaic (PV) power source system to supply up to 75 kW of electrical power average during the orbital period. The electrical power requirements are to be met by a combination of PV source, storage, and control elements for the sun and eclipse periods. The authors discuss the application of power electronics and controls to manage the generation, storage, and distribution of power to meet the station loads, as well as the computer models used for analysis and simulation of the PV power system. The requirements for power source integrated controls to adjust storage charge power during the insolation period current limiting, breaker interrupt current values, and the electrical fault protection approach are defined. Based on these requirements, operating concepts have been defined which then become drivers for specific system and element design.

  15. Electric Power Plants and Generation Stations - POWER_HAZUS_IN: Electric Power Facilities in Indiana, Derived from HAZUS (Federal Emergency Management Agency, Point Shapefile)

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — POWER_HAZUS_IN is a point shapefile that shows locations of electric power facilities in Indiana. POWER_HAZUS_IN was derived from the shapefile named "ELECTRIC." A...

  16. Thermoelectrical power stations in 1967

    Energy Technology Data Exchange (ETDEWEB)

    Medici, M. (University of Padova, Italy)

    1968-01-01

    In Italy in 1967, geothermal electric power production was 2.66% of the national energy production. The implementation of traditional and nuclear power plants is described. The trend in conventional thermoelectric power plants is characterized by ever-increasing block capacities (100-160 MW at present), they are expected to increase to 600 MW in Europe and to 1200 MW in the USA 10 years from now. Nuclear power plants with pressurized-water reactors, boiling-water reactors, and graphite-gas reactors have been built recently in Italy. Studies are being conducted in the area of high-speed reactors and breeder reactors. A description is presented of a power station using geothermal energy. At the end of 1967, geothermal power plants with an electrical capacity of 340 MW were in operation. Generally, U.S. thermoelectrical engine blocks with high productivity were used. The thermodynamic characteristics of these blocks are described in detail. The most powerful engine in the field in Italy- a turbocompressore Franco Tosi- was constructed in the ENEL central Castlenuovo Val Cecina in the Larderello region. The compressor is fed by a combined flow of steam, CO/sub 2/ and H/sub 2/S. It is characterized by a load of 22 t/h and an input pressure of 0.0905 atm at the outlet. The absorbed power is 2.28 MW at a velocity of 50 rotations/sec. Thirty figures are presented.

  17. Safety Analysis and Countermeasures of Photovoltaic Power Station Grid-connected Power Generation at Shizuishan%石嘴山地区光伏电站并网发电安全分析及对策

    Institute of Scientific and Technical Information of China (English)

    齐秀芳

    2012-01-01

    Based on the description of the principle, advantages and disadvantages of the solar photovoltaic power generation system, the paper analyzes the operation of photovoltaic power station access system, and puts forward the control measures.%通过对太阳能光伏发电系统的原理,优、缺点的介绍,对我局光伏电站接入系统进行运行分析,提出控制措施.

  18. Lunar Base Thermoelectric Power Station Study

    Science.gov (United States)

    Determan, William; Frye, Patrick; Mondt, Jack; Fleurial, Jean-Pierre; Johnson, Ken; Stapfer, Gerhard; Brooks, Michael; Heshmatpour, Ben

    2006-01-01

    Under NASA's Project Prometheus, the Nuclear Space Power Systems Program, the Jet Propulsion Laboratory, Pratt & Whitney Rocketdyne, and Teledyne Energy Systems have teamed with a number of universities, under the Segmented Thermoelectric Multicouple Converter (STMC) Task, to develop the next generation of advanced thermoelectric converters for space reactor power systems. Work on the STMC converter assembly has progressed to the point where the lower temperature stage of the segmented multicouple converter assembly is ready for laboratory testing, and promising candidates for the upper stage materials have been identified and their properties are being characterized. One aspect of the program involves mission application studies to help define the potential benefits from the use of these STMC technologies for designated NASA missions such as a lunar base power station where kilowatts of power would be required to maintain a permanent manned presence on the surface of the moon. A modular 50 kWe thermoelectric power station concept was developed to address a specific set of requirements developed for this particular mission concept. Previous lunar lander concepts had proposed the use of lunar regolith as in-situ radiation shielding material for a reactor power station with a one kilometer exclusion zone radius to minimize astronaut radiation dose rate levels. In the present concept, we will examine the benefits and requirements for a hermetically-sealed reactor thermoelectric power station module suspended within a man-made lunar surface cavity. The concept appears to maximize the shielding capabilities of the lunar regolith while minimizing its handling requirements. Both thermal and nuclear radiation levels from operation of the station, at its 100-m exclusion zone radius, were evaluated and found to be acceptable. Site preparation activities are reviewed as well as transport issues for this concept. The goal of the study was to review the entire life cycle of the

  19. Baseline Testing of the Ultracapacitor Enhanced Photovoltaic Power Station

    Science.gov (United States)

    Eichenberg, Dennis J.; Kolacz, John S.; Tavernelli, Paul F.

    2001-01-01

    The NASA John H. Glenn Research Center is developing an advanced ultracapacitor enhanced photovoltaic power station. Goals of this effort include maximizing photovoltaic power generation efficiency and extending the life of photovoltaic energy storage systems. Unique aspects of the power station include the use of a solar tracker, and ultracapacitors for energy storage. The photovoltaic power station is seen as a way to provide electric power in remote locations that would otherwise not have electric power, provide independence form utility systems, reduce pollution, reduce fossil fuel consumption, and reduce operating costs. The work was done under the Hybrid Power Management (HPM) Program, which includes the Hybrid Electric Transit Bus (HETB), and the E-Bike. The power station complements the E-Bike extremely well in that it permits the charging of the vehicle batteries in remote locations. Other applications include scientific research and medical power sources in isolated regions. The power station is an inexpensive approach to advance the state of the art in power technology in a practical application. The project transfers space technology to terrestrial use via nontraditional partners, and provides power system data valuable for future space applications. A description of the ultracapacitor enhanced power station, the results of performance testing and future power station development plans is the subject of this report. The report concludes that the ultracapacitor enhanced power station provides excellent performance, and that the implementation of ultracapacitors in the power system can provide significant performance improvements.

  20. Special Protection Scheme at BTPS Power Station

    Science.gov (United States)

    Ballal, Makarand Sudhakar; Suryawanshi, Hiralal Murlidhar; Ballal, Deepali Makarand; Mishra, Mahesh Kumar

    2016-03-01

    After 2003 free licensees' act in power sector, it is observed that many power plants from public sector as well as from private sectors are going to be commissioned. The load growth in India is about more than 10% pa. As these plants are going to connect to the power grid, therefore the grid is going to become more complicated. Also the problems related to grid stability are enhanced. There shall be possibilities regarding failure of grid system and under such circumstance it is always desirable to island minimum single generating unit in power plant of specified geographical area. After islanding the generating unit, this unit has to survive not only for the restoration of grid but also for power supply to important consumers. For the grid stability and effective survival of islanded generating unit, it is mandatory to maintain the power balance equation. This paper focuses on the lacunae's observed in implementation of special protection scheme to carry out islanding operation at Bhusawal Thermal Power Station (BTPS) by considering the case studies. The concepts of islanding, load shedding, generator tripping and along with importance of power balance equation is discussed. Efforts are made to provide the solution for the survival of islanding scheme.

  1. Nuclear power generation incorporating modern power system practice

    CERN Document Server

    Myerscough, PB

    1992-01-01

    Nuclear power generation has undergone major expansion and developments in recent years; this third edition contains much revised material in presenting the state-of-the-art of nuclear power station designs currently in operation throughout the world. The volume covers nuclear physics and basic technology, nuclear station design, nuclear station operation, and nuclear safety. Each chapter is independent but with the necessary technical overlap to provide a complete work on the safe and economic design and operation of nuclear power stations.

  2. Analysis methodology of power generation/cogeneration designs in VNG (Vehicular Natural Gas) stations; Metodologia de analise de projetos de geracao/cogeracao em postos GNV (Gas Natural Veicular)

    Energy Technology Data Exchange (ETDEWEB)

    Romanos, Rafael Reami [Companhia de Gas de Santa Catarina (SCGAS), Florianopolis, SC (Brazil)

    2008-07-01

    This work presents the methodology for analysis of generation/cogeneration projects in NGV filling stations, determining the influence of critical parameters in its technical-economic viability. To achieve this methodology, it was necessary to define parameters that influence directly or indirectly the size of a generating system, as the total electric demand of the filling station, ratio (power of the compressor) / (total installed power), load factor, factor of simultaneity, technical data of major equipment, among others. The methodology has been validated by comparing with data measured in a NGV filling station and allows screening and identifying customers with technical feasibility to evolve in a generation or cogeneration project. The cogeneration with NG generators was highlighted during the analysis of the NGV filling stations and was feasible for establishments which have large thermal demand, as filling stations along the road with large amounts of electric showers in changing rooms. (author)

  3. Selective analysis of power plant operation on the Hudson River with emphasis on the Bowline Point Generating Station. Volume 1. [Effects on striped bass population

    Energy Technology Data Exchange (ETDEWEB)

    Barnthouse, L. W.; Cannon, J. B.; Christensen, S. G.

    1977-07-01

    A comprehensive study of the effects of power plant operation on the Hudson River was conducted. The study included thermal, biological, and air quality effects of existing and planned electrical generating stations. This section on thermal impacts presents a comprehensive mathematical modeling and computer simulation study of the effects of heat rejection from the plants. The overall study consisted of three major parts: near-field analysis; far-field analysis; and zone-matched near-field/far-field analysis. Near-field analyses were completed for Roseton, Danskammer, and Bowline Point Generating Stations, and near-field dilution ratios range from a low of about 2 for Bowline Point and 3 for Roseton to a maximum of 6 for both plants. The far-field analysis included a critical review of existing studies and a parametric review of operating plants. The maximum thermal load case, based on hypothetical 1974 river conditions, gives the daily maximum cross-section-averaged and 2-mile-segment-averaged water temperatures as 83.80/sup 0/F in the vicinity of the Indian Point Station and 83.25/sup 0/F in the vicinity of the Bowline Station. This maximum case will be significantly modified if cooling towers are used at certain units. A full analysis and discussion of these cases is presented. A study of the Hudson River striped bass population is divided into the following eight subsections: distribution of striped bass eggs, larvae, and juveniles in the Hudson River; entrainment mortality factor; intake factor; impingement; effects of discharges; compensation; model estimates of percent reduction; and Hudson River striped bass stock.

  4. 76 FR 19476 - Exelon Generation Company, LLC, Peach Bottom Atomic Power Station, Unit Nos. 2 and 3; Exemption

    Science.gov (United States)

    2011-04-07

    .... Standard-383, ``IEEE Standard For Qualifying Class 1E Electrical Cables And Field Splices for Nuclear Power... hereafter in effect. The facility consists of two boiling-water reactors located partly in Peach Bottom... Regulations (10 CFR), Part 50, Section 50.48(b), requires that nuclear power plants that were licensed before...

  5. 76 FR 52357 - Exelon Generation Company, LLC; PSEG Nuclear, LLC; Peach Bottom Atomic Power Station, Unit 3...

    Science.gov (United States)

    2011-08-22

    ... Branch 1-2, Division of Operating Reactor Licensing, Office of Nuclear Reactor Regulation, U.S. Nuclear... Power Ratio (SLMCPR) values. The SLMCPR is established to assure that at least 99.9% of the fuel rods in... Reactor Fuel,'' Revision 18. The basis of the SLMCPR calculation is to ensure that during normal...

  6. Nagymaros power station on the River Danube

    Energy Technology Data Exchange (ETDEWEB)

    Kobilka, J.

    1987-02-01

    This article deals with the economic aspects of Austrian cooperation in power station construction as practised in the consulting activities of Oesterreichische Donaukraftwerke AG, and discusses in detail this company's participation in the construction of the main structure for the Nagymaros power station on the Danube under a general contract.

  7. Prediction and modeling of the two-dimensional separation characteristic of a steam generator at a nuclear power station with VVER-1000 reactors

    Science.gov (United States)

    Parchevsky, V. M.; Guryanova, V. V.

    2017-01-01

    A computational and experimental procedure for construction of the two-dimensional separation curve (TDSC) for a horizontal steam generator (SG) at a nuclear power station (NPS) with VVER-reactors. In contrast to the conventional one-dimensional curve describing the wetness of saturated steam generated in SG as a function of the boiler water level at one, usually rated, load, TDSC is a function of two variables, which are the level and the load of SGB that enables TDSC to be used for wetness control in a wide load range. The procedure is based on two types of experimental data obtained during rated load operation: the nonuniformity factor of the steam load at the outlet from the submerged perforated sheet (SPS) and the dependence of the mass water level in the vicinity of the "hot" header on the water level the "cold" end of SG. The TDSC prediction procedure is presented in the form of an algorithm using SG characteristics, such as steam load and water level as the input and giving the calculated steam wetness at the output. The zoneby-zone calculation method is used. The result is presented in an analytical form (as an empirical correlation) suitable for uploading into controllers or other controls. The predicted TDSC can be used during real-time operation for implementation of different wetness control scenarios (for example, if the effectiveness is a priority, then the minimum water level, minimum wetness, and maximum turbine efficiency should be maintained; if safety is a priority, then the maximum level at the allowable wetness and the maximum water inventory should be kept), for operation of NPS in controlling the frequency and power in a power system, at the design phase (as a part of the simulation complex for verification of design solutions), during construction and erection (in developing software for personnel training simulators), during commissioning tests (to reduce the duration and labor-intensity of experimental activities), and for training.

  8. Conversion options for Peterhead Power Station

    Energy Technology Data Exchange (ETDEWEB)

    Dibble, I.R.; O' Donnell, I.H. [Scottish Hydro-Electric plc, Perth (United Kingdom); Hunt, G.F. [Thermoflow Ltd., Tewkesbury (United Kingdom)

    1999-07-01

    The two gas/oil-fired 660 MW generating sets at Scottish Hydro-Electric's Peterhead Power Station were originally commissioned in 1981/2 and in order to remain competitive it was essential to upgrade the plant. This paper describes the plant performance aspects of a study carried out by Scottish Hydro-Electric to identify the possible routes for plant modification and the associated efficiency of each option. Scottish Hydro-Electric employed the suite of Thermoflow programs to carry out the performance study. These programs had sufficient flexibility to model the performance of the original plant and then to analyse the variety of re-powering options available, using the original accurate modes as the basis. (author)

  9. Micro hydro-electric power stations

    Energy Technology Data Exchange (ETDEWEB)

    Monition, L.; Le Nir, M.; Roux, J.

    1984-01-01

    This book provides a discussion of all aspects of hydro-power exploitation using micro-power stations. It offers guidance to techniques for assessing the power available from a given stream, designing and building siteworks, selecting the appropriate turbine types for given conditions, and measuring and controlling environmental hazards associated with micro-hydro installations.

  10. Power generation technologies

    CERN Document Server

    Breeze, Paul

    2014-01-01

    The new edition of Power Generation Technologies is a concise and readable guide that provides an introduction to the full spectrum of currently available power generation options, from traditional fossil fuels and the better established alternatives such as wind and solar power, to emerging renewables such as biomass and geothermal energy. Technology solutions such as combined heat and power and distributed generation are also explored. However, this book is more than just an account of the technologies - for each method the author explores the economic and environmental costs and risk factor

  11. ALGORITHM TO CHOOSE ENERGY GENERATION MULTIPLE ROLE STATION

    Directory of Open Access Journals (Sweden)

    Alexandru STĂNESCU

    2014-05-01

    Full Text Available This paper proposes an algorithm that is based on a complex analysis method that is used for choosing the configuration of a power station. The station generates electric energy and hydrogen, and serves a "green" highway. The elements that need to be considered are: energy efficiency, location, availability of primary energy sources in the area, investment cost, workforce, environmental impact, compatibility with existing systems, meantime between failure.

  12. SCAP optimization of the Pasajes de San Juan power station

    Energy Technology Data Exchange (ETDEWEB)

    Perez, L.; Perez, J.M.; Cerezo, J.; Catediano, J.; Martin-Sanchez, J.M. [Iberdrola, Bilbao (Spain)

    1995-08-01

    In July 1990 the company Iberduero, now Iberdrola, decided to carry out a development project using the Spanish technology SCAP in the Pasajes de San Juan power plant. This methodology, featured by the utilization of adaptive predictive control methodology, had been successfully applied in order to achieve the optimization of other industrial processes. The ultimate aim of this project was the replacement of the power station conventional control system, with a SCAP control system with a distributed structure able to optimize the electric energy generation process by optimizing power station operation, maximizing efficiency and working life, reducing maintenance costs, and increasing safety and availability. The project was divided into two stages to evaluate the quality of SCAP technology in the control and optimization of a power station. In the present report, the results obtained in the control of the most critical variables during the power station operation are gathered together. Beforehand, and in order to place these results in a suitable context, the project proceedings summarized in the following phases are considered: the SCAP technology; problems in a thermal power plant; and the Pasajes de San Juan power plant and its control system. The results are presented through comparative graphs that show the performance of the SCAP system as compared to the power station conventional control. 17 figs., 4 tabs., 11 refs.

  13. Solar power stations for all roofs - two enterprises combine solar power generations and franchising; Fuer jedes Dach ein Solarkraftwerk - wie zwei Unternehmer Sonnenenergie und Franchising verbinden

    Energy Technology Data Exchange (ETDEWEB)

    Meyeren, T. von

    1997-12-31

    A project is presented in which two partners cooperate in roof-mounted solar power units. Prospects are good: Although the German market for photovolatic systems is still not in full swing, there are good chances worldwide. (orig.) [Deutsch] `Die Zeit is reif, etwas zu tun` fanden Lothar Kuhn, Elektromeister aus Starzach in Wuerttemberg, und Alfred Ritter, Inhaber des Schokoladen-Unternehmens Ritter Sport, angesichts der Zurueckhaltung der grossen deutschen Energieunternehmen gegenueber der Solar-Energie. Sie beschlossen, sich der Energieinteressen der Menschen konstruktiv anzunehmen, der eine - Alfred Ritter - als Kapitalgeber, der andere - Lothar Kuhn - als geschaeftsfuehrender Gesellschafter der im Juni 1996 gegruendeten Sunlive Solarnetwork GmbH and Co KG, auf Schloss Weitenburg in Starzach und zugleich Experte auf dem Gebiet der Solarstrom-Erzeugung. Die Vision:Jedes Dach soll ein solares E-Werk werden. Die Chancen: Nie besser als heute. Der deutsche Photovoltaik-Markt ist unterentwickelt, Prognosen bescheinigen jedoch weltweit gross Entwicklungschancen in wirtschaftlicher und technischer Hinsicht.(orig./AKF)

  14. Next Generation Power and Energy

    Science.gov (United States)

    2010-12-02

    Cells Advanced Generators Direct Conversion Photovoltaics Future Fuels Energy Storage Batteries Capacitors Flywheels Motors & Actuators Motors Actuators...Generation Power Distribution Energy Storage Power Conversion Propulsion Ship’s Power Sources Mission Systems Industry Competes for Components; ‘Submit...Chiller Technologies / HVAC ONR Maintaining Robust S&T Investment Power LoadSystem Control Power Generation Power Distribution Energy Storage Power

  15. Gearless wind power generator

    Energy Technology Data Exchange (ETDEWEB)

    Soederlund, L.; Ridanpaeae, P.; Vihriaelae, H.; Peraelae, R. [Tampere Univ. of Technology (Finland). Lab. of Electricity and Magnetism

    1998-12-31

    During the wind power generator project a design algorithm for a gearless permanent magnet generator with an axially orientated magnetic flux was developed and a 10 kW model machine was constructed. Utilising the test results a variable wind speed system of 100 kW was designed that incorporates a permanent magnet generator, a frequency converter and a fuzzy controller. This system produces about 5-15% more energy than existing types and stresses to the blades are minimised. The type of generator designed in the project represents in general a gearless solution for slow-speed electrical drives. (orig.)

  16. A review and management of AAR at Mactaquac Generating Station

    Energy Technology Data Exchange (ETDEWEB)

    Gilks, P.; May, T. [Mactaquac Generating Station, Keswick Ridge, NB (Canada). Hydro Division; Curtis, D. [Acres International Ltd., Niagara Falls, ON (Canada)

    2001-10-01

    Located on the Saint John River, approximately 20 kilometres upstream from Fredericton, New Brunswick, the Mactaquac Generating Station possesses an installed capacity of 660 MW and is owned and operated by New Brunswick Power Corporation (NB Power). Constructed in stages between 1964 and 1980, it is the largest hydroelectric generating station in all of the Maritimes. The history of the generating station is explained in this paper, where the emphasis is placed on the effects of alkali-silica reaction (AAR) and the measures that were taken to remedy the situation and ensure the safe operation of the generating station. A rigorous engineering and construction program was implemented by NB Power at Mactaquac following the diagnosis of AAR. Some of the measures included in the engineering and construction program were: installation of tendons in the intake, slot cutting, grouting of the concrete structures and their foundations, and installation of flexible couplings in the penstocks. The authors had three objectives with this presentation: a review of the effects caused by AAR on the concrete structures, the investigations that were performed, and the remedial action implemented to rectify the situation. A brief overview of every major measure implemented is provided. 8 refs., 14 figs.

  17. Water turbine technology for small power stations

    Science.gov (United States)

    Salovaara, T.

    1980-02-01

    The paper examines hydro-power stations and the efficiency and costs of using water turbines to run them. Attention is given to different turbine types emphasizing the use of Kaplan-turbines and runners. Hydraulic characteristics and mechanical properties of low head turbines and small turbines, constructed of fully fabricated steel plate structures, are presented.

  18. Toluene stability Space Station Rankine power system

    Science.gov (United States)

    Havens, V. N.; Ragaller, D. R.; Sibert, L.; Miller, D.

    1987-01-01

    A dynamic test loop is designed to evaluate the thermal stability of an organic Rankine cycle working fluid, toluene, for potential application to the Space Station power conversion unit. Samples of the noncondensible gases and the liquid toluene were taken periodically during the 3410 hour test at 750 F peak temperature. The results obtained from the toluene stability loop verify that toluene degradation will not lead to a loss of performance over the 30-year Space Station mission life requirement. The identity of the degradation products and the low rates of formation were as expected from toluene capsule test data.

  19. Milliwatt radioisotope power supply for the PASCAL Mars surface stations

    Science.gov (United States)

    Allen, Daniel T.; Murbach, Marcus S.

    2001-02-01

    A milliwatt power supply is being developed based on the 1 watt Light-Weight Radioisotope Heater Unit (RHU), which has already been used to provide heating alone on numerous spacecraft. In the past year the power supply has been integrated into the design of the proposed PASCAL Mars Network Mission, which is intended to place 24 surface climate monitoring stations on Mars. The PASCAL Mars mission calls for the individual surface stations to be transported together in one spacecraft on a trajectory direct from launch to orbit around Mars. From orbit around Mars each surface station will be deployed on a SCRAMP (slotted compression ramp) probe and, after aerodynamic and parachute deceleration, land at a preselected location on the planet. During descent sounding data and still images will be accumulated, and, once on the surface, the station will take measurements of pressure, temperature and overhead atmospheric optical depth for a period of 10 Mars years (18.8 Earth years). Power for periodic data acquisition and transmission to orbital then to Earth relay will come from a bank of ultracapacitors which will be continuously recharged by the radioisotope power supply. This electronic system has been designed and a breadboard built. In the ultimate design the electronics will be arrayed on the exterior surface of the radioisotope power supply in order to take advantage of the reject heat. This assembly in turn is packaged within the SCRAMP, and that assembly comprises the surface station. An electrically heated but otherwise prototypical power supply was operated in combination with the surface station breadboard system, which included the ultracapacitors. Other issues addressed in this work have been the capability of the generator to withstand the mechanical shock of the landing on Mars and the effectiveness of the generator's multi-foil vacuum thermal insulation. .

  20. Numerical flow analysis of hydro power stations

    Science.gov (United States)

    Ostermann, Lars; Seidel, Christian

    2017-07-01

    For the hydraulic engineering and design of hydro power stations and their hydraulic optimisation, mainly experimental studies of the physical submodel or of the full model at the hydraulics laboratory are carried out. Partially, the flow analysis is done by means of computational fluid dynamics based on 2D and 3D methods and is a useful supplement to experimental studies. For the optimisation of hydro power stations, fast numerical methods would be appropriate to study the influence of a wide field of optimisation parameters and flow states. Among the 2D methods, especially the methods based on the shallow water equations are suitable for this field of application, since a lot of experience verified by in-situ measurements exists because of the widely used application of this method for the problems in hydraulic engineering. As necessary, a 3D model may supplement subsequently the optimisation of the hydro power station. The quality of the results of the 2D method for the optimisation of hydro power plants is investigated by means of the results of the optimisation of the hydraulic dividing pier compared to the results of the 3D flow analysis.

  1. Practical design considerations for photovoltaic power station

    Science.gov (United States)

    Swanson, T. D.

    Aspects of photovoltaic (PV) technology are discussed along with generic PV design considerations, taking into account the resource sunlight, PV modules and their reliability, questions of PV system design, the support structure subsystem, and a power conditioning unit subsystem. A description is presented of two recent projects which demonstrate the translation of an idea into actual working PV systems. A privately financed project in Denton, Maryland, went on line in early December, 1982, and began providing power to the local utility grid. It represents the first intermediate size, grid-connected, privately financed power station in the U.S. Based on firm quotes, the actual cost of this system is about $13/W peak. The other project, called the PV Breeder, is an energy independent facility which utilizes solar power to make new solar cells. It is also the first large industrial structure completely powered by the sun.

  2. Growing the Space Station's electrical power plant

    Science.gov (United States)

    Sundberg, Gale R.

    For over a decade NASA LeRC has been defining, demonstrating, and evaluating power electronic components and multi-kilowatt, multiply redundant, electrical power systems as part of OAST charter. Whether one considers aircraft (commercial transport/military), Space Station Freedom, growth station, launch vehicles, or the new Human Exploration Initiative, the conclusions remain the same: high frequency AC power distribution and control is superior to all other approaches for achieving a fast, smart, safe, versatile, and growable electrical power system that will meet a wide range of mission options. To meet the cost and operability goals of future aerospace missions that require significantly higher electrical power and longer durations, we must learn to integrate multiple technologies in ways that enhance overall system synergisms. The way NASA is doing business in space electric power is challenged and some approaches for evolving large space vehicles and platforms in well constructed steps to provide safe, ground testable, growable, smart systems that provide simple, replicative logic structures, which enable hardware and software verification, validation, and implementation are proposed. Viewgraphs are included.

  3. Wind power. [electricity generation

    Science.gov (United States)

    Savino, J. M.

    1975-01-01

    A historical background on windmill use, the nature of wind, wind conversion system technology and requirements, the economics of wind power and comparisons with alternative systems, data needs, technology development needs, and an implementation plan for wind energy are presented. Considerable progress took place during the 1950's. Most of the modern windmills feature a wind turbine electricity generator located directly at the top of their rotor towers.

  4. Space Station Freedom secondary power wiring requirements

    Science.gov (United States)

    Sawyer, C. R.

    1994-09-01

    Secondary power is produced by DDCU's (direct current to direct current converter units) and routed to and through secondary power distribution assemblies (SPDA's) to loads or tertiary distribution assemblies. This presentation outlines requirements of Space Station Freedom (SSF) EEE (electrical, electronic, and electromechanical) parts wire and the approved electrical wire and cable. The SSF PDRD (Program Definition and Requirements Document) language problems and resolution are reviewed. The cable routing to and from the SPDA's is presented as diagrams and the wire recommendations and characteristics are given.

  5. High Falls generation station expansion approvals process

    Energy Technology Data Exchange (ETDEWEB)

    Litschko, C. [Lakeland Holding, Bracebridge, ON (Canada)

    2005-07-01

    Lakeland Holding Ltd. is the parent company for Lakeland Power Distribution Ltd., Bracebridge Generation Ltd., and Lakeland Energy Ltd. This PowerPoint presentation highlighted the High Falls generation expansion process. During construction of the High Falls plant, a concrete foundation was built beside the plant for future expansion. The expansion process involves building a 1,500 kilowatt generator to supply electricity to as many as 1600 households. The presentation described the context and background for the expansion and presented information on the water power generation plants. It presented site specifications as well as the approvals process by which final approval was granted in 2004. Observations and lessons learned from the approval process were identified. figs.

  6. Conventional and intelligent generalized supervisory control for combined cycle generating power stations.; Control supervisiorio generalizado convencional e inteligente para centrales de generacion de ciclo combinado

    Energy Technology Data Exchange (ETDEWEB)

    Martinez M, Miguel A; Sanchez P, Marino [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico); Gonzalez Rubio S, Jose L [Cento Nacional de Investigacion y Desarrollo Tecnologico (Cenidet), Cuernavaca, Morelos (Mexico)

    2005-07-01

    Under the expectations of expansion of electric power generation in Mexico, this work exposes the development of a conventional and intelligent generalized supervisory control (CSG) for a combined cycle generation power plant. This one allows to obtain the optimal operation of the power plant through the automatic starting of the generating units and to obtain the maximum possible amount of electrical power in automatic and safe form. For the development of the CSG a control loop by temperature was implemented for the gas turbine system and a control loop by strangled pressure for the gas turbine and a control loop by strangled pressure for the steam turbine. The design of these supervisory systems was made with base in the critical limits on the involved variables of the process: blading average temperature, for the gas turbine (GT) and strangled pressure for the steam turbine (ST) [Spanish] Bajo estas expectativas de expansion de generacion de energia en Mexico, este trabajo expone el desarrollo de un control supervisorio generalizado (CSG) para una central generacion de ciclo combinado. Este permite lograr la operacion optima de la planta a traves del arranque automatico de las unidades generadoras y obtener la maxima cantidad posible de potencia electrica en forma automatica y segura. Para el desarrollo del CSG se implanto un lazo de control por temperatura para el sistema de turbina de gas y un lazo de control por presion estrangulada para la turbina de gas y un lazo de control por presion estrangulada para la turbina de vapor. El diseno de estos sistemas supervisorio se realizo con base en los limites criticos de las variables del proceso involucradas: temperatura promedio de empaletado para la turbina de gas (TG) y presion estrangulada para la turbina de vapor (TV)

  7. Thermal control system for Space Station Freedom photovoltaic power module

    Science.gov (United States)

    Hacha, Thomas H.; Howard, Laura

    1994-01-01

    The electric power for Space Station Freedom (SSF) is generated by the solar arrays of the photovoltaic power modules (PVM's) and conditioned, controlled, and distributed by a power management and distribution system. The PVM's are located outboard of the alpha gimbals of SSF. A single-phase thermal control system is being developed to provide thermal control of PVM electrical equipment and energy storage batteries. This system uses ammonia as the coolant and a direct-flow deployable radiator. The description and development status of the PVM thermal control system is presented.

  8. Waste heat rejection from geothermal power stations

    Energy Technology Data Exchange (ETDEWEB)

    Robertson, R.C.

    1978-12-01

    This study of waste heat rejection from geothermal power stations is concerned only with the heat rejected from the power cycle. The heat contained in reinjected or otherwise discharged geothermal fluids is not included with the waste heat considered here. The heat contained in the underflow from the flashtanks in such systems is not considered as part of the heat rejected from the power cycle. By following this definition of the waste heat to be rejected, various methods of waste heat dissipation are discussed without regard for the particular arrangement to obtain heat from the geothermal source. Recent conceptual design studies made for 50-MW(e) geothermal power stations at Heber and Niland, California, are of particular interst. The former uses a flashed-steam system and the latter a binary cycle that uses isopentane. In last-quarter 1976 dollars, the total estimated capital costs were about $750/kW and production costs about 50 mills/kWhr. If wet/dry towers were used to conserve 50% of the water evaporation at Heber, production costs would be about 65 mills/kWhr.

  9. Retrofitting automated process control systems at Ukrainian power stations

    Energy Technology Data Exchange (ETDEWEB)

    B.E. Simkin; V.S. Naumchik; B.D. Kozitskii (and others) [OAO L' vovORGRES, Lviv (Ukraine)

    2008-04-15

    Approaches and principles for retrofitting automated process control systems at Ukrainian power stations are considered. The results obtained from retrofitting the monitoring and control system of Unit 9 at the Burshtyn thermal power station are described.

  10. Virtual Generation (Energy Efficiency) The Cheapest Source For Power Generation

    Energy Technology Data Exchange (ETDEWEB)

    Hasnie, Sohail

    2010-09-15

    Energy efficiency is the cheapest source of energy that has escaped the minds of the politicians in the developing countries. This paper argues for large scale utility led end use efficiency programs in a new paradigm, where 1 million efficient light bulbs is synonymous to a 50 MW power station that costs only 2% of the traditional fossil fuel power station and zero maintenance. Bulk procurement, setting up new standards and generation of certified emissions reduction is part of this strategy. It discusses implementation of a $20 million pilot in the Philippines supported by the Asian Development Bank.

  11. GEOTHERMAL POWER GENERATION PLANT

    Energy Technology Data Exchange (ETDEWEB)

    Boyd, Tonya

    2013-12-01

    Oregon Institute of Technology (OIT) drilled a deep geothermal well on campus (to 5,300 feet deep) which produced 196oF resource as part of the 2008 OIT Congressionally Directed Project. OIT will construct a geothermal power plant (estimated at 1.75 MWe gross output). The plant would provide 50 to 75 percent of the electricity demand on campus. Technical support for construction and operations will be provided by OIT’s Geo-Heat Center. The power plant will be housed adjacent to the existing heat exchange building on the south east corner of campus near the existing geothermal production wells used for heating campus. Cooling water will be supplied from the nearby cold water wells to a cooling tower or air cooling may be used, depending upon the type of plant selected. Using the flow obtained from the deep well, not only can energy be generated from the power plant, but the “waste” water will also be used to supplement space heating on campus. A pipeline will be construction from the well to the heat exchanger building, and then a discharge line will be construction around the east and north side of campus for anticipated use of the “waste” water by facilities in an adjacent sustainable energy park. An injection well will need to be drilled to handle the flow, as the campus existing injection wells are limited in capacity.

  12. Geothermal Power Generation Plant

    Energy Technology Data Exchange (ETDEWEB)

    Boyd, Tonya [Oregon Inst. of Technology, Klamath Falls, OR (United States). Geo-Heat Center

    2013-12-01

    Oregon Institute of Technology (OIT) drilled a deep geothermal well on campus (to 5,300 feet deep) which produced 196°F resource as part of the 2008 OIT Congressionally Directed Project. OIT will construct a geothermal power plant (estimated at 1.75 MWe gross output). The plant would provide 50 to 75 percent of the electricity demand on campus. Technical support for construction and operations will be provided by OIT’s Geo-Heat Center. The power plant will be housed adjacent to the existing heat exchange building on the south east corner of campus near the existing geothermal production wells used for heating campus. Cooling water will be supplied from the nearby cold water wells to a cooling tower or air cooling may be used, depending upon the type of plant selected. Using the flow obtained from the deep well, not only can energy be generated from the power plant, but the “waste” water will also be used to supplement space heating on campus. A pipeline will be construction from the well to the heat exchanger building, and then a discharge line will be construction around the east and north side of campus for anticipated use of the “waste” water by facilities in an adjacent sustainable energy park. An injection well will need to be drilled to handle the flow, as the campus existing injection wells are limited in capacity.

  13. Electric Power Plants and Generation Stations, File name = UTILITIES - PARTIAL Data is incomplete. Contains electric trans lines, electric substations, sewer plants, sewer pumpstations, water plants, water tanks http://www.harfordcountymd.gov/gis/Index.cfm, Published in 2011, 1:2400 (1in=200ft) scale, Harford County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Electric Power Plants and Generation Stations dataset current as of 2011. File name = UTILITIES - PARTIAL Data is incomplete. Contains electric trans lines, electric...

  14. Station power supply by residual steam of Fugen

    Energy Technology Data Exchange (ETDEWEB)

    Kamiya, Y.; Kato, H.; Hattori, S. (Power Reactor and Nuclear Fuel Development Corp., Tokyo (Japan))

    1981-09-01

    In the advanced thermal reactor ''Fugen'', when the sudden decrease of load more than 40% occurs due to the failure of power system, the turbine regulating valve is rapidly shut, and the reactor is brought to scrum. However, the operation of turbo-generators is continued with the residual steam in the reactor, and the power for inside the station is supplied for 30 sec by the limiting timer, then the power-generating plant is automatically stopped. The reasons why such design was adopted are to reduce manual operation at the time of emergency, to continue water supply for cooling the reactor and to maintain the water level in the steam drum, and to reduce steam release from the safety valve and the turbine bypass valve. The output-load unbalance relay prevents the everspeed of the turbo-generator when load decreased suddenly, but when the failure of power system is such that recovers automatically in course of time, it does not work. The calculation for estimating the dynamic characteristics at the time of the sole operation within the station is carried out by the analysis code FATRAC. The input conditions for the calculation and the results are reported. Also the dynamic characteristics were actually tested to confirm the set value of the limiting timer and the safe working of turbine and generator trips. The estimated and tested results were almost in agreement.

  15. Impacts of the pumped storage power station on the wind generation integration capability of the Shandong Power Grid%抽水蓄能电站对山东电网风电接纳能力的影响

    Institute of Scientific and Technical Information of China (English)

    宋豪; 宋曙光; 王超; 刘远龙; 于大洋; 韩学山

    2011-01-01

    将抽水蓄能机组纳入机组组合问题当中,据此建立了含风电与抽水蓄能电站的系统优化运行模型。以山东电网实际系统为例,根据机组组合的结果分析了不同季节典型日下抽水蓄能电站对于风电接入电网各项指标的影响。结果表明,当风电容量较小时,抽水蓄能电站的作用不明显;只有当风电容量超出系统的接纳能力出现弃风以后,抽水蓄能电站的作用才得以体现出来,风电并网的各项指标随抽水蓄能电站容量的增加有明显的改善。%The pumped storage power station was considered in unit commitment problem.Based on this,an optimal operation model of the power system was built.The impacts of the pumped storage power station(PSPS) with different capacities to targets of grid-connected wind power in a typical day in different seasons were analyzed according to unit commitment results based on the Shandong Power Grid.The results showed that the impact was not obvious when capacity of wind power was small.The targets were improved with increasing the pumped power storage station until the capacity of wind power was so large that some wind power was abandoned.

  16. Electrical Power Station Theory. A Course of Technical Information for Electrical Power Station Wireman Apprentices. Revised Edition.

    Science.gov (United States)

    Lane Community Coll., Eugene, OR.

    This third-year course for electrical power station wirer apprentices is a foundation for the study of all aspects of installation and maintenance of power station equipment. It also provides a good technical background as well as the general knowledge essential to power station operator trainees. The course is intended to be equivalent to a…

  17. Solar Powered Radioactive Air Monitoring Stations

    Energy Technology Data Exchange (ETDEWEB)

    Barnett, J. Matthew; Bisping, Lynn E.; Gervais, Todd L.

    2013-10-30

    Environmental monitoring of ambient air for radioactive material is required as stipulated in the PNNL Site radioactive air license. Sampling ambient air at identified preferred locations could not be initially accomplished because utilities were not readily available. Therefore, solar powered environmental monitoring systems were considered as a possible option. PNNL purchased two 24-V DC solar powered environmental monitoring systems which consisted of solar panels, battery banks, and sampling units. During an approximate four month performance evaluation period, the solar stations operated satisfactorily at an on-site test location. They were subsequently relocated to their preferred locations in June 2012 where they continue to function adequately under the conditions found in Richland, Washington.

  18. Commentary: childhood cancer near nuclear power stations

    Directory of Open Access Journals (Sweden)

    Fairlie Ian

    2009-09-01

    Full Text Available Abstract In 2008, the KiKK study in Germany reported a 1.6-fold increase in solid cancers and a 2.2-fold increase in leukemias among children living within 5 km of all German nuclear power stations. The study has triggered debates as to the cause(s of these increased cancers. This article reports on the findings of the KiKK study; discusses past and more recent epidemiological studies of leukemias near nuclear installations around the world, and outlines a possible biological mechanism to explain the increased cancers. This suggests that the observed high rates of infant leukemias may be a teratogenic effect from incorporated radionuclides. Doses from environmental emissions from nuclear reactors to embryos and fetuses in pregnant women near nuclear power stations may be larger than suspected. Hematopoietic tissues appear to be considerably more radiosensitive in embryos/fetuses than in newborn babies. Recommendations for advice to local residents and for further research are made.

  19. Navajo Generating Station and Air Visibility Regulations: Alternatives and Impacts

    Energy Technology Data Exchange (ETDEWEB)

    Hurlbut, D. J.; Haase, S.; Brinkman, G.; Funk, K.; Gelman, R.; Lantz, E.; Larney, C.; Peterson, D.; Worley, C.; Liebsch, E.

    2012-01-01

    Pursuant to the Clean Air Act, the U.S. Environmental Protection Agency (EPA) announced in 2009 its intent to issue rules for controlling emissions from Navajo Generating Station that could affect visibility at the Grand Canyon and at several other national parks and wilderness areas. The final rule will conform to what EPA determines is the best available retrofit technology (BART) for the control of haze-causing air pollutants, especially nitrogen oxides. While EPA is ultimately responsible for setting Navajo Generating Station's BART standards in its final rule, it will be the U.S. Department of the Interior's responsibility to manage compliance and the related impacts. This study aims to assist both Interior and EPA by providing an objective assessment of issues relating to the power sector.

  20. Energy Sharing Framework for Microgrid-Powered Cellular Base Stations

    KAUST Repository

    Farooq, Muhammad Junaid

    2017-02-07

    Cellular base stations (BSs) are increasingly becoming equipped with renewable energy generators to reduce operational expenditures and carbon footprint of wireless communications. Moreover, advancements in the traditional electricity grid allow two-way power flow and metering that enable the integration of distributed renewable energy generators at BS sites into a microgrid. In this paper, we develop an optimized energy management framework for microgrid-connected cellular BSs that are equipped with renewable energy generators and finite battery storage to minimize energy cost. The BSs share excess renewable energy with others to reduce the dependency on the conventional electricity grid. Three cases are investigated where the renewable energy generation is unknown, perfectly known, and partially known ahead of time. For the partially known case where only the statistics of renewable energy generation are available, stochastic programming is used to achieve a conservative solution. Results show the time varying energy management behaviour of the BSs and the effect of energy sharing between them.

  1. Next Generation Hydrogen Station Composite Data Products: Retail Stations, Data through Quarter 4 of 2016

    Energy Technology Data Exchange (ETDEWEB)

    Sprik, Sam [National Renewable Energy Lab. (NREL), Golden, CO (United States); Kurtz, Jennifer [National Renewable Energy Lab. (NREL), Golden, CO (United States); Ainscough, Chris [National Renewable Energy Lab. (NREL), Golden, CO (United States); Saur, Genevieve [National Renewable Energy Lab. (NREL), Golden, CO (United States); Peters, Michael [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2017-05-31

    This publication includes 86 composite data products (CDPs) produced for next generation hydrogen stations, with data through the fourth quarter of 2016. These CDPs include data from retail stations only.

  2. Next Generation Hydrogen Station Composite Data Products: Retail Stations, Data Through Quarter 3 of 2016

    Energy Technology Data Exchange (ETDEWEB)

    Sprik, Sam [National Renewable Energy Lab. (NREL), Golden, CO (United States); Kurtz, Jennifer [National Renewable Energy Lab. (NREL), Golden, CO (United States); Ainscough, Chris [National Renewable Energy Lab. (NREL), Golden, CO (United States); Saur, Genevieve [National Renewable Energy Lab. (NREL), Golden, CO (United States); Peters, Michael [National Renewable Energy Lab. (NREL), Golden, CO (United States); Jeffers, Matthew [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2017-03-07

    This publication includes 80 composite data products (CDPs) produced in Spring 2016 for next generation hydrogen stations, with data through the third quarter of 2016. These CDPs include data from retail stations only.

  3. Gearless wind power generator

    Energy Technology Data Exchange (ETDEWEB)

    Soederlund, L.; Ridanpaeae, P.; Vihriaelae, H.; Peraelae, R. [Tampere Univ. of Technology (Finland). Lab. of Electricity and Magnetism

    1998-10-01

    In the project a 100 kW axial flux permanent magnet wind power generator has been designed. The toroidal stator with air gap winding is placed between two rotating discs with permanent magnets. The magnet material is NdBFe due to its excellent magnetic properties compared to other materials. This type of topology enables a very large number of poles compared to conventional machine of the same size. A large number of poles is required to achieve a low rotational speed and consequently a direct driven system. The stator winding is formed by rectangular coils. The end winding is very short leading to small resistive losses. On the other hand, the absence of iron teeth causes eddy current losses in the conductors. These can be restricted to an acceptable level by keeping the wire diameter and flux density small. This means that the number of phases should be large. Several independent three phase systems may be used. The toothless stator also means that the iron losses are small and there exists no cogging torque

  4. A Series Dissertation on Tianwan Nuclear Power Station--Summary of Tianwan Nuclear Power Station Project

    Institute of Scientific and Technical Information of China (English)

    Li Qiankun

    2006-01-01

    This is a summary in relation to the construction and operation of Tianwan Nuclear Power Station (the Project) at Lianyungang, Jiangsu Province, the People' s Republic of China. The breakdown specialty topic shall been given in times to come. In this report, the author attempted to give some general description of the Project, including the Project site' s general layout and geographical conditions. A description of its exposure to the elements is also provided, supported by some data made available to us. The key component parts of the Project are described, namely, the nuclear island which includes the reactor, steam generator and so on; the conventional island and the balance of plant. Wherever possible, the improvements to the reactor design over the operating V320 are highlighted, which result in the V428 reactor model. The supplier and contractor for the major equipment such as the reactor and the turbine is the Russian company, namely Atomstroyexport (ASE). There are third country suppliers who provide other equipment. For instance, Siemens supplies the full digital I&C system and Framatome ANP supplies the emergency diesel generators; the metal-clad switchgear cabinet by ABB of Australia; the main steam isolation valve unit by CCI AG of Switzerland. All these foreign suppliers are well known globally. Their experience and quality of the equipment supplied by them are well recognized by the people in the respective fields. As for the civil work and erection work, the most experienced and trustworthy local contractors have been selected. These contractors have proven their competence in similar contract work before. For the testing of the equipment, stringent and proper procedures which meet international standards are adopted. Finally, the author wished on this report could provide the world a safety and advanced Nuclear Project building in China.

  5. Generation Mechanism of Human Errors and Preventive Countermeasures in Nuclear Power Stations%核电站人因失误的产生机理及其预防措施

    Institute of Scientific and Technical Information of China (English)

    张言滨

    2011-01-01

    在核电站的人-机系统中,核电站特有的运行控制特征使得人因失误事件的发生概率很大,如何预防与减少人因失误,提高人的可靠性已成为保证核电安全生产的主要因素.研究了人因失误的特点,通过总结核电站人因失误事件的产生机理,给出了预防核电站人因失误的有效措施.%In the person -machine system of a nuclear power station, the unique operating control characteristics of the station increase probability of human failure events. How to prevent from and reduce human errors have become the primary factor in nuclear power safety producUon. This paper studied the characteristics of human errors, and through summarizing of generation mechanism of human failure events, and proposed some effective prevention measures.

  6. Coal fired power stations and the environment

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, S.H.

    1982-12-01

    Environmental problems resulting from the use of coal in power stations were discussed in a conference in Copenhagen in August, 1982. Topics included: 1) Discussions of the adverse temperature effects of cooling tower water. The pathogenic amoeba Naegleria fowleri has been isolated in two of eight cooling tower systems; 2) Uses of power plant ash. Dense blocks of the ash have been used to build artificial reefs with, as yet, not adverse effects on the marine community; 3) Long-range transport of particulates which bind heavy metals in the ash; and 4) The effects of acid rain. An examination of the fish status of Scandanavian lakes did not reveal a simple relationship between pH and fishlessness. It was concluded that levels of calcium and aluminum, food supply, genetically determined tolerance and ecological factors have also played a part in the fish regime of acid-affected lakes. The Norwegian attitude is that there are good grounds for thinking acid rain is a global problem implicating the discharge of nitrogen and sulfur oxides and either micropollutants. (JMT)

  7. 77 FR 135 - Exelon Generation Company, LLC, Oyster Creek Nuclear Generating Station; Exemption

    Science.gov (United States)

    2012-01-03

    ... From the Federal Register Online via the Government Publishing Office NUCLEAR REGULATORY COMMISSION Exelon Generation Company, LLC, Oyster Creek Nuclear Generating Station; Exemption 1.0 Background...-16, which authorizes operation of the Oyster Creek Nuclear Generating Station (OCNGS). The...

  8. A Day-Ahead Dispatching Strategy for Power Pool Composed of Wind Farms, Photovoltaic Generations, Pumped-Storage Power Stations, Gas Turbine Power Plants and Energy Storage Systems Based on Multi Frequency Scale Analysis%基于功率多频率尺度分析的风光水气储联合系统日前调度策略

    Institute of Scientific and Technical Information of China (English)

    马静; 石建磊; 李文泉; 王增平

    2013-01-01

    Based on multi frequency scale analysis on power output of wind farms and photovoltaic (PV) generation (PWP), a day-ahead dispatching strategy for power pool composed of wind farms, photovoltaic generations, pumped-storage power stations, gas turbine power plants and energy storage systems is proposed. Firstly, according to the control objectives the filter analysis on PWP is performed to extract PWP components corresponding to different frequency scales to draft output schedulings for of all kinds of complementary power generations in the power pool; then using improved particle swamp optimization (PSO) the total power output of the power pool is computed;finally, based on different day-ahead dispatching modes and considering stability and wind power accommodation capability of the power pool, the per-unit generation costs of wind farms, photovoltaic generations, pumped-storage power stations, gas turbine power plants and energy storage systems are optimized to draft final output schedulings. Results of calculation example show that comparing with traditional optimization models and optimization algorithms, the proposed method can cope with the power fluctuation due to grid-connection of large-scale wind farms and PV generations to implement stationary power output of the power pool, meanwhile the economy, efficiency, low-carbon operation and environmental protection of the power pool can be ensured.%  提出一种基于功率多频率尺度分析的风光水气储联合系统日前调度策略。该策略首先根据控制目标对风光出力(power of wind photovoltaic,PWP)进行滤波分析,提取不同频率尺度下的PWP分量,制定各类补偿电站出力计划;然后利用改进粒子群优化算法并行优化各电站内部综合成本,计算联合系统总体输出功率;最后依据不同日前调度模式,考虑稳定性和风光消纳能力,优化风光水气储系统单位发电成本,制定出力计划。算例分析结果

  9. Modern power station practice incorporating modern power system practice

    CERN Document Server

    Reynolds, PM

    1992-01-01

    This volume contains two additional features which enhance the value of Modern Power Station Practice as a whole: a cumulative subject index and a detailed list of tables of contents for the entire work. The cumulative index provides access to the vast body of information presented in the set, and also indicates at a glance the breadth and depth of the treatment through the use of inclusive page ranges for major topics. In order to allow the reader the greatest flexibility in using the index there are many cross-references. The entries themselves are qualified by up to two descriptive subheadi

  10. User Context Aware Base Station Power Flow Model

    OpenAIRE

    Walsh, Barbara; Farrell, Ronan

    2005-01-01

    At present the testing of power amplifiers within base station transmitters is limited to testing at component level as opposed to testing at the system level. While the detection of catastrophic failure is possible, that of performance degradation is not. This paper proposes a base station model with respect to transmitter output power with the aim of introducing system level monitoring of the power amplifier behaviour within the base station. Our model reflects the expe...

  11. Aquatic impacts from operation of three midwestern nuclear power stations: Fort Calhoun station, Unit No. 1 environmental appraisal report

    Energy Technology Data Exchange (ETDEWEB)

    El-Shamy, F.

    1981-10-01

    Fort Calhoun Station, Unit 1, is located on the west bank of the Missouri River in Washington County, Nebraska. The station, a nuclear powered generating facility producing 475 net megawatts, utilizes a once-through cooling design. The station influences the aquatic biota of the Missouri River vicinity in several ways. The heated discharges of the station were found to have no significant impacts to fish, periphyton, and benthic macroinvertebrates. Minor effects to phytoplankton were noted in warm summer months at the point of discharge. An estimated 227,900,000 fish larvae were entrained annually from the river's ichthyoplankton community, the majority identified as freshwater drum. Fort Calhoun Station impinged an estimated 170,882 fish annually, large numbers of which were freshwater drum and gizzard shad with potential losses to channel and flathead catfish. The station was shown to have little impact on the zooplankton community.

  12. Next-Generation GPS Station for Hazards Mitigation (Invited)

    Science.gov (United States)

    Bock, Y.

    2013-12-01

    Our objective is to better forecast, assess, and mitigate natural hazards, including earthquakes, tsunamis, and extreme storms and flooding through development and implementation of a modular technology for the next-generation in-situ geodetic station to support the flow of information from multiple stations to scientists, mission planners, decision makers, and first responders. The same technology developed under NASA funding can be applied to enhance monitoring of large engineering structures such as bridges, hospitals and other critical infrastructure. Meaningful warnings save lives when issued within 1-2 minutes for destructive earthquakes, several tens of minutes for tsunamis, and up to several hours for extreme storms and flooding, and can be provided by on-site fusion of multiple data types and generation of higher-order data products: GPS/GNSS and accelerometer measurements to estimate point displacements, and GPS/GNSS and meteorological measurements to estimate moisture variability in the free atmosphere. By operating semi-autonomously, each station can then provide low-latency, high-fidelity and compact data products within the constraints of narrow communications bandwidth that often accompanies natural disasters. We have developed a power-efficient, low-cost, plug-in Geodetic Module for fusion of data from in situ sensors including GPS, a strong-motion accelerometer module, and a meteorological sensor package, for deployment at existing continuous GPS stations in southern California; fifteen stations have already been upgraded. The low-cost modular design is scalable to the many existing continuous GPS stations worldwide. New on-the-fly data products are estimated with 1 mm precision and accuracy, including three-dimensional seismogeodetic displacements for earthquake, tsunami and structural monitoring and precipitable water for forecasting extreme weather events such as summer monsoons and atmospheric rivers experienced in California. Unlike more

  13. "Life without nuclear power": A nuclear plant retirement formulation model and guide based on economics. San Onofre Nuclear Generating Station case: Economic impacts and reliability considerations leading to plant retirement

    Science.gov (United States)

    Wasko, Frank

    Traditionally, electric utilities have been slow to change and very bureaucratic in nature. This culture, in and of itself, has now contributed to a high percentage of United States electric utilities operating uneconomical nuclear plants (Crooks, 2014). The economic picture behind owning and operating United States nuclear plants is less than favorable for many reasons including rising fuel, capital and operating costs (EUCG, 2012). This doctoral dissertation is specifically focused on life without nuclear power. The purpose of this dissertation is to create a model and guide that will provide electric utilities who currently operate or will operate uneconomical nuclear plants the opportunity to economically assess whether or not their nuclear plant should be retired. This economic assessment and stakeholder analysis will provide local government, academia and communities the opportunity to understand how Southern California Edison (SCE) embraced system upgrade import and "voltage support" opportunities to replace "base load" generation from San Onofre Nuclear Generating Station (SONGS) versus building new replacement generation facilities. This model and guide will help eliminate the need to build large replacement generation units as demonstrated in the SONGS case analysis. The application of The Nuclear Power Retirement Model and Guide will provide electric utilities with economic assessment parameters and an evaluation assessment progression needed to better evaluate when an uneconomical nuclear plant should be retired. It will provide electric utilities the opportunity to utilize sound policy, planning and development skill sets when making this difficult decision. There are currently 62 nuclear power plants (with 100 nuclear reactors) operating in the United States (EIA, 2014). From this group, 38 are at risk of early retirement based on the work of Cooper (2013). As demonstrated in my model, 35 of the 38 nuclear power plants qualify to move to the economic

  14. Fuel Characteristics of Thermal Power Station as Index of Its Thermal Efficiency

    Directory of Open Access Journals (Sweden)

    A. E. Piir

    2006-01-01

    Full Text Available It is proposed to calculate values of specific consumptions of conventional fuel for generating heat and electric power in a combined electrical installation (Thermal Power Station on the basis of a thermal and dynamic approach or an exergetic balance of a turbine plant. It is shown that a fuel characteristic of Thermal Power Station is an objective index of a thermal electrical installation

  15. Floating type ocean wave power station equipped with hydroelectric unit

    Science.gov (United States)

    Okamoto, Shun; Kanemoto, Toshiaki; Umekage, Toshihiko

    2013-10-01

    The authors have invented the unique ocean wave power station, which is composed of the floating type platform with a pair of the floats lining up at the interval of one wave pitch and the counter-rotating type wave power unit, its runners are submerged in the seawater at the middle position of the platform. Such profiles make the flow velocity at the runner is twice faster than that of the traditional fixed/caisson type OWC, on the ideal flow conditions. Besides, the runners counter-rotate the inner and the outer armatures of the peculiar generator, respectively, and the relative rotational speed is also twice faster than the speed of the single runner/armature. Such characteristics make the runner diameter large, namely the output higher, as requested, because the torque of the power unit never act on the floating type platform. At the preliminary reseach, this paper verifies to get the power using a Wells type single runner installed in the model station. The runner takes the output which is affected by the oscillating amplitude of the platform, the rotational speed and the inertia force of the runner, etc.

  16. Advanced IGCC technology for competitive power generation

    Energy Technology Data Exchange (ETDEWEB)

    Baumann, H.-R.; Ullrich, N.; Haupt, G.; Zimmermann, G.; Pruschek, R.; Oeljeklaus, G. [Krupp Uhde GmbH (Germany)

    1998-12-31

    The paper reports interim results of a comprehensive ongoing study of potential for development funded by the European Commission. First, the status of the advanced IGCC technology is described. This IGCC 98 concept, including what has been achieved in 1998, results in net station efficiencies around 52% according to the site conditions prevailing in Denmark, where one of the world`s most modern pulverised-coal-fired power plants (design efficiency 47%) is currently under construction. The advanced IGCC station will be equipped with PRENFLO gasification developed by Krupp and a Siemens Model V94.3A gas turbine-generator. The second section depicts the results of a detailed cost estimate based on Western European conditions and aimed at clearly lower specific capital investment for an IGCC power plant. This cost estimate is based mainly on bidding information from competent manufacturers and suggests that the target purchase price of 1,100 US dollars per kW installed capacity is likely to be verified in the near future. One main factor contributing to achievement of this figure is the tremendous increase in net power output to about 450 MW with nearly the same absolute capital investment as for IGCC plants designed previously. Consequently, this permits IGCC generating costs surely lower than those of a comparable pulverised-coal-fired (PCF) steam power plant, so that the advanced IGCC stations described in this paper can be regarded as truly competitive. 2 refs., 3 figs., 3 tabs.

  17. RF power generation

    CERN Document Server

    Carter, R G

    2011-01-01

    This paper reviews the main types of r.f. power amplifiers which are, or may be, used for particle accelerators. It covers solid-state devices, tetrodes, inductive output tubes, klystrons, magnetrons, and gyrotrons with power outputs greater than 10 kW c.w. or 100 kW pulsed at frequencies from 50 MHz to 30 GHz. Factors affecting the satisfactory operation of amplifiers include cooling, matching and protection circuits are discussed. The paper concludes with a summary of the state of the art for the different technologies.

  18. Dry cooling of power generating stations: a summary of the economic evaluation of several advanced concepts via a design optimization study and a conceptual design and cost estimate

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, B.M.; Allemann, R.T.; Faletti, D.W.; Fryer, B.C.; Zaloudek, F.R.

    1976-09-01

    Due to enhanced concern about water supplies and water use priorities, dry cooling systems for thermal power plants are receiving increased consideration, even though electric power from dry-cooled power plants currently costs 10 to 15 percent more than power from wet-cooled plants. A two-year study which analyzed the performance of existing dry-cooled systems and which developed economic and performance models for cost optimization of dry-cooled systems is reported. First, a design optimization code was used to compare the cost of a number of advanced all-dry systems. Then, 5 different dry/wet systems were carried through conceptual design and cost estimating. The results showed for either an all dry or a combination wet-and-dry cooling system, cost optimization can be achieved with an advanced system using ammonia as an intermediate heat exchange fluid (between the turbine and the dry tower), and that development of the ammonia concept should procede in order to provide performance and reliability data for the ammonia system. (LCL)

  19. Automated electric power management and control for Space Station Freedom

    Science.gov (United States)

    Dolce, James L.; Mellor, Pamela A.; Kish, James A.

    1990-01-01

    A comprehensive automation design is being developed for Space Station Freedom's electric power system. It strives to increase station productivity by applying expert systems and conventional algorithms to automate power system operation. An integrated approach to the power system command and control problem is defined and used to direct technology development in: diagnosis, security monitoring and analysis, battery management, and cooperative problem-solving for resource allocation. The prototype automated power system is developed using simulations and test-beds.

  20. Modernisation work commences at the Moabit power station

    Energy Technology Data Exchange (ETDEWEB)

    1988-09-01

    A major part of the modernisation programme for existing power stations is the replacement of combustion block 2 at the Moabit power station by a new circulating fluidised-bed combustor, whose reduced emissions of sulphur dioxide, nitrogen oxides and dust eliminate the need for downstream flue-gas desulphurisation.

  1. Power generation, operation and control

    CERN Document Server

    Wood, Allen J; Sheblé, Gerald B

    2013-01-01

    Since publication of the second edition, there have been extensive changes in the algorithms, methods, and assumptions in energy management systems that analyze and control power generation. This edition is updated to acquaint electrical engineering students and professionals with current power generation systems. Algorithms and methods for solving integrated economic, network, and generating system analysis are provided. Also included are the state-of-the-art topics undergoing evolutionary change, including market simulation, multiple market analysis, multiple interchange contract analysis, c

  2. Dynamic characteristics of power-tower space stations with 15-foot truss bays

    Science.gov (United States)

    Dorsey, J. T.

    1986-01-01

    A power tower space station concept which generates power with photovoltaic arrays and where the truss structure has a bay size of 15 ft is described. Rigid body and flexible body dynamic characteristics are presented for a 75-kW Initial Operating Capability (IOC) and 150-kW and 300-kW growth stations. The transient response of the IOC and 300-kW growth stations to shuttle dock, orbit reboost, and mobile remote manipulator system translation loads are studied. Displacements, accelerations, and bending moments at various locations on the IOC and 300-kW growth stations are presented.

  3. Microfluidic Power Generation

    Science.gov (United States)

    2008-03-28

    electricity and magnetism we of ancient time, neither one had any practical application at the time and were simply observed as curiosities [24]. The first...mechanical energy to magnetic energy. The water flowing through the microchannels will induce mechanical pressure on the turbine, causing it to rotate...C. Panchal, and L. Genens, "Design and Cost of Near-term OTEC Plants for the Production of Desalinated Water adn Electric Power," U. S. D. o. Energy

  4. Power Generation for River and Tidal Generators

    Energy Technology Data Exchange (ETDEWEB)

    Muljadi, Eduard [National Renewable Energy Lab. (NREL), Golden, CO (United States); Wright, Alan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Gevorgian, Vahan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Donegan, James [Ocean Renewable Power Company (ORPC), Portland, ME (United States); Marnagh, Cian [Ocean Renewable Power Company (ORPC), Portland, ME (United States); McEntee, Jarlath [Ocean Renewable Power Company (ORPC), Portland, ME (United States)

    2016-06-01

    Renewable energy sources are the second largest contributor to global electricity production, after fossil fuels. The integration of renewable energy continued to grow in 2014 against a backdrop of increasing global energy consumption and a dramatic decline in oil prices during the second half of the year. As renewable generation has become less expensive during recent decades, and it becomes more accepted by the global population, the focus on renewable generation has expanded from primarily wind and solar to include new types with promising future applications, such as hydropower generation, including river and tidal generation. Today, hydropower is considered one of the most important renewable energy sources. In river and tidal generation, the input resource flow is slower but also steadier than it is in wind or solar generation, yet the level of water turbulent flow may vary from one place to another. This report focuses on hydrokinetic power conversion.

  5. Boxberg III-2 x 500 MW units: Refurbishing and environmental protection measures on the 815 T/H steam generator of works II in Boxberg Power Station

    Energy Technology Data Exchange (ETDEWEB)

    Cossman, R.; Fritz, M.; Bauchmueller, R. [L& C Steinmueller GmbH, Gummersbach (Germany)

    1995-12-01

    The object of the upgrading measures on the steam generators is: (1) To comply with the requirements of the German antipollution law, which imposes a permissible NO{sub x} content in the flue gas of less than 200 Mg/m{sup 3} STP and a CO content of less than 250 Mg/m{sup 3} STP. (2) To increase the boiler efficiency and availability and the efficiency of the water/steam cycle.

  6. Influence of Mobile Users' Density Distribution on the CDMA Base Station Power

    Science.gov (United States)

    Lebl, Aleksandar; Mitić, Dragan; Popović, Miroslav; Markov, Žarko; Mileusnić, Mladen; Matić, Vladimir

    2016-12-01

    In this paper we analyze the influence of users' density distribution in one cell of CDMA mobile network (ie adjusted power control on the forward link) on base station emission power. This influence is analyzed for different circles radii around base station within which same emission power is generated for all mobile users, and for different values of propagation loss coefficient. It is proved that emission power in this cell must be increased comparing to the similar cell, which uses complete power control. The power increase is greater when greater number of users are situated near base station, and for greater values of propagation loss coefficient. The results are presented, illustrated by numerical examples and verified by simulation for three users' density distributions: uniform, decreasing and increasing density from the base station to the cell rim. The simulation process, which is based on random traffic process, is presented briefly.

  7. Power generation, operation, and control

    CERN Document Server

    Wood, Allen J

    2012-01-01

    A comprehensive text on the operation and control of power generation and transmission systems In the ten years since Allen J. Wood and Bruce F. Wollenberg presented their comprehensive introduction to the engineering and economic factors involved in operating and controlling power generation systems in electric utilities, the electric power industry has undergone unprecedented change. Deregulation, open access to transmission systems, and the birth of independent power producers have altered the structure of the industry, while technological advances have created a host of new opportunities

  8. Electric power management for the International Space Station experiment racks

    Energy Technology Data Exchange (ETDEWEB)

    Burcham, M. [Boeing Missile and Space, Huntsville, AL (United States); Darty, M.A.; Thibodeau, P.E. [McDonnell Douglas Aerospace, Huntsville, AL (United States); Coe, R. [SCI Systems, Inc., Huntsville, AL (United States); Dunn, M. [Europa Ltd., Glenrothes (United Kingdom)

    1995-12-31

    An intelligent, all solid state, electric power management system for International Space Station experiment racks is described. This power system is implemented via redundant internal microcomputers, controlling hybridized solid state power controllers in response to 1553B data bus commands. The solid state power controllers are programmable for current trip level and for normally-open or normally-closed operation.

  9. Mathematical modeling of vibrations in turbogenerator sets of Sayano-Shushenskaya Hydroelectric Power Station

    Science.gov (United States)

    Leonov, G. A.; Kuznetsov, N. V.; Solovyeva, E. P.

    2016-02-01

    Oscillations in turbogenerator sets, which consist of a synchronous generator, a hydraulic turbine, and an automatic speed regulator, are investigated. This study was motivated by the emergency that took place at the Sayano-Shushenskaya Hydroelectric Power Station in 2009. During modeling of the parameters of turbogenerator sets of the Sayano-Shushenskaya Hydroelectric Power Station, the ranges corresponding to undesired oscillation regimes were determined. These ranges agree with the results of the full-scale tests of the hydropower units of the Sayano-Shushenskaya Hydroelectric Power Station performed in 1988.

  10. Performance of International Space Station Alpha electric power systems

    Energy Technology Data Exchange (ETDEWEB)

    Hill, R.; Lu, C.Y.; Padhye, V.; Hajela, G.; Hague, L. [Rockwell International, Canoga Park, CA (United States). Rocketdyne Division

    1995-12-31

    The International Space Station Alpha (ISSA) will be an Earth-orbiting laboratory in space. It will house experimental payloads, distribute resource utilities, and support human habitation for conducting research and science experiments in a microgravity environment. Electrical power is a major utility to support successful achievement of the mission goal. The ISSA United States On-Orbit Segment (USOS) Electric Power System (EPS) power generation capability will vary with orbital parameters, natural and induced environment, and hardware aging/replacement throughout the ISSA life. Power capability will be further restricted by various assembly configurations during ISSA buildup, by various flight attitudes, by shadowing on the solar arrays, by EPS operational constraints, such as pointing accuracy, battery charging, as well as operating voltage setpoints, and by ISSA operational constraints either to avoid long-term solar array shadowing from the adjacent solar array or to accommodate ISSA maneuver during proximity operations with other space vehicles, mating, and departing. Design of the ISSA USOS EPS takes into consideration the various equipment degradation modes, operation constraints, and orbital conditions to make it compatible with the environments and to meet power, lifetime, and performance requirements.

  11. 47 CFR 74.793 - Digital low power TV and TV translator station protection of broadcast stations.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Digital low power TV and TV translator station... DISTRIBUTIONAL SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.793 Digital low power TV and TV... TV or TV translator station or change the facilities of an existing station will not be accepted...

  12. Information system for data management of civil buildings instrumentation in generating power stations; Sistema de informacion para el manejo de datos de la instrumentacion de las obras civiles de las centrales generadoras

    Energy Technology Data Exchange (ETDEWEB)

    Alvarado, Alonso; Escamilla, Juan Carlos; Alaniz, Felipe de Jesus [Instituto de Investigaciones Electricas, Cuernavaca (Mexico); Gonzalez, Francisco; Mena, Enrique [Comision Federal de Electricidad, Mexico, D. F. (Mexico)

    1997-12-31

    A relevant task performed by Comision Federal de Electricidad (CFE) is the analysis of the structural behavior and safety assessment of the country`s large electric energy generating stations. This task is performed capturing, revising an analyzing the information generated by measuring instruments installed in the power station civil structures. Such activity generates a large amount of data and the collection, analysis and assessment is a long and tiresome process; additionally, the generated information is kept in plain isolated files, that causes sluggishness in the process and delays in the access to the information. This article describes the characteristics of the Information System for Structure Measurements (Sistema de Informacion de Medicion de Estructuras) (SIME), developed by the Instituto de Investigaciones Electricas (IIE) for CFE in order to enhance the opportunity for the information management. SIME captures, arranges, stores and reports the data obtained from the measurements at the works with great efficiency and flexibility. This system is part of another of greater scope with which CFE will ensure an optimum operation condition of its civil buildings. [Espanol] Una tarea relevante que realiza la Comision Federal de Electricidad (CFE) es analizar el comportamiento estructural y evaluar la seguridad de las grandes obras generadoras de energia electrica del pais. Esta tarea la realiza capturando, revisando y analizando la informacion que generan instrumentos de medicion instalados en las estructuras civiles de las centrales. Tal actividad genera gran cantidad de datos y el proceso de recopilacion, analisis y evaluacion es tardado y tedioso; ademas, la informacion que se genera se guarda en archivos planos aislados, lo que ocasiona lentitud en el proceso y retraso en el acceso a la informacion. Este articulo describe las caracteristicas del Sistema de Informacion de Medicion de Estructuras (SIME) desarrollado por el Instituto de Investigaciones

  13. Station planning and design incorporating modern power system practice

    CERN Document Server

    Martin, PC

    1991-01-01

    The planning and design of new power stations can involve complex interaction between the many engineering disciplines involved as well as environmental, planning, economical, political and social pressures. This volume aims to provide a logical review of the procedures involved in power station development. The engineering aspects are outlined in detail, with examples, showing the basis of the relationships involved together with ""non-engineering"" factors so that the engineer can draw on the information provided for specific projects. The civil engineering and building of power stations are

  14. Solar Power Station Output Inverter Control Design

    Directory of Open Access Journals (Sweden)

    J. Bauer

    2011-04-01

    Full Text Available The photovoltaic applications spreads in these days fast, therefore they also undergo great development. Because the amount of the energy obtained from the panel depends on the surrounding conditions, as intensity of the sun exposure or the temperature of the solar array, the converter must be connected to the panel output. The Solar system equipped with inverter can supply small loads like notebooks, mobile chargers etc. in the places where the supplying network is not present. Or the system can be used as a generator and it shall deliver energy to the supply network. Each type of the application has different requirements on the converter and its control algorithm. But for all of them the one thing is common – the maximal efficiency. The paper focuses on design and simulation of the low power inverter that acts as output part of the whole converter. In the paper the design of the control algorithm of the inverter for both types of inverter application – for islanding mode and for operation on the supply grid – is discussed. Attention is also paid to the design of the output filter that should reduce negative side effects of the converter on the supply network.

  15. Harmonic incursion at the point of common coupling due to small grid-connected power stations

    Directory of Open Access Journals (Sweden)

    Majid Mumtaz

    2015-12-01

    Full Text Available The orthodox electric power distribution systems used to be generally radial and direction of flow of power was often from grid towards consumer. Sometimes, the transmission of power generated from newly set small power stations by using transmission network is not feasible due to the transmission losses, service cost on transmission lines and other related issues. That is why, in many cases, small power stations are connected directly to the local distribution network. These small power stations inject active and reactive power to the existing network, badly disturbing the flow of power hence injecting harmonics in the system at the point of common coupling (PCC. This harmonic injection at PCC due to a direct grid-connection of small power stations to the existing large electric power systems is identified. Also, the impact of harmonic incursion by these small generation units is analysed using a straightforward and an effortless method. This simulation based method uses power system components simplified to basic inductive and capacitive elements and can be very helpful for a fast assessment of harmonic incursion at PCC if extended to the practical large inter-connected electric power systems.

  16. 75 FR 43915 - Basin Electric Power Cooperative: Deer Creek Station

    Science.gov (United States)

    2010-07-27

    ... purchasing power on the volatile open electric market. The Action Alternative at White Site 1 would be... Rural Utilities Service Basin Electric Power Cooperative: Deer Creek Station AGENCY: Rural Utilities... CFR Part 1794), and the Western Area Power Administration's (Western) NEPA implementing regulations...

  17. The Environment Friendly Power Source for Power Supply of Mobile Communication Base Stations

    Science.gov (United States)

    Rudenko, N. V.; Ershov, V. V.; Evstafiev, V. V.

    2017-05-01

    The article describes the technical proposals to improve environmental and resource characteristics of the autonomous power supply systems of mobile communication base stations based on renewable energy sources, while ensuring the required reliability and security of power supply. These include: the replacement of diesel-generator with clean energy source - an electrochemical generator based on hydrogen fuel cells; the use of wind turbines with a vertical axis; use of specialized batteries. Based on the analysis of the know technical solutions, the structural circuit diagram of the hybrid solar-wind-hydrogen power plant and the basic principles of the algorithm of its work were proposed. The implementation of these proposals will improve the environmental and resource characteristics.

  18. 76 FR 79227 - Exemption Request Submitted by Oyster Creek Nuclear Generating Station; Exelon Generation Company...

    Science.gov (United States)

    2011-12-21

    ... COMMISSION Exemption Request Submitted by Oyster Creek Nuclear Generating Station; Exelon Generation Company... Generation Company, LLC (the licensee), for operation of the Oyster Creek Nuclear Generating Station (Oyster... for Oyster Creek and NUREG-1437, Vol. 1, Supplement 28, ``Generic Environmental Impact Statement...

  19. 75 FR 33656 - Exelon Generation Company, LLC Oyster Creek Nuclear Generating Station Environmental Assessment...

    Science.gov (United States)

    2010-06-14

    ... COMMISSION Exelon Generation Company, LLC Oyster Creek Nuclear Generating Station Environmental Assessment....2, as requested by Exelon Generation Company, LLC (the licensee), for operation of the Oyster Creek Nuclear Generating Station (Oyster Creek), located in Ocean County, New Jersey. Therefore, as required...

  20. Taming power: Generative historical consciousness.

    Science.gov (United States)

    Winter, David G

    2016-04-01

    Power is a necessary dimension of all human enterprises. It can inspire and illuminate, but it can also corrupt, oppress, and destroy. Therefore, taming power has been a central moral and political question for most of human history. Writers, theorists, and researchers have suggested many methods and mechanisms for taming power: through affiliation and love, intellect and reason, responsibility, religion and values, democratic political structures, and separation of powers. Historical examples and social science research suggest that each has some success, but also that each is vulnerable to being hijacked by power itself. I therefore introduce generative historical consciousness (GHC) as a concept and measure that might help to secure the benefits of power while protecting against its outrages and excesses. I conclude by discussing the role that GHC may have played in the peaceful resolution of the Cuban Missile Crisis of 1962.

  1. Retrieval of Intermediate Level Waste at Trawsfyndd Nuclear Power Station

    Energy Technology Data Exchange (ETDEWEB)

    Wall, S.; Shaw, I.

    2002-02-25

    In 1996 RWE NUKEM Limited were awarded two contracts by BNFL Magnox Generation as part of the decommissioning programme for the Trawsfynydd power station. From the normal operations of the two Magnox reactors, intermediate level waste (ILW) had accumulated on site, this was Miscellaneous Activated Components (MAC) and Fuel Element Debris (FED). The objective of these projects is retrieval of the waste from storage vaults, monitoring, packaging and immobilization in a form suitable for on site storage in the medium term and eventual disposal to a waste repository. The projects involve the design, supply, commissioning and operation of equipment to retrieve, pack and immobilize the waste, this includes recovery from vaults in both reactor and pond locations and final decommissioning and removal of plant from site after completion of waste recovery.

  2. Design of photovoltaic central power station concentrator array

    Energy Technology Data Exchange (ETDEWEB)

    1984-02-01

    A design for a photovoltaic central power station using tracking concentrators has been developed. The 100 MW plant is assumed to be located adjacent to the Saguaro Power Station of Arizona Public Service. The design assumes an advanced Martin Marietta two-axis tracking fresnel lens concentrator. The concentrators are arrayed in 5 MW subfields, each with its own power conditioning unit. The photovoltaic plant output is connected to the existing 115 kV switchyard. The site specific design allows detailed cost estimates for engineering, site preparation, and installation. Collector and power conditioning costs have been treated parametrically.

  3. Power Generation from Coal 2011

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-07-01

    This report focuses mainly on developments to improve the performance of coal-based power generation technologies, which should be a priority -- particularly if carbon capture and storage takes longer to become established than currently projected. A close look is taken of the major ongoing developments in process technology, plant equipment, instrumentation and control. Coal is an important source of energy for the world, particularly for power generation. To meet the growth in demand for energy over the past decade, the contribution from coal has exceeded that of any other energy source. Additionally, coal has contributed almost half of total growth in electricity over the past decade. As a result, CO2 emissions from coal-fired power generation have increased markedly and continue to rise. More than 70% of CO2 emissions that arise from power generation are attributed to coal. To play its role in a sustainable energy future, its environmental footprint must be reduced; using coal more efficiently is an important first step. Beyond efficiency improvement, carbon capture and storage (CCS) must be deployed to make deep cuts in CO2 emissions. The need for energy and the economics of producing and supplying it to the end-user are central considerations in power plant construction and operation. Economic and regulatory conditions must be made consistent with the ambition to achieve higher efficiencies and lower emissions. In essence, clean coal technologies must be more widely deployed.

  4. Power generation from solid fuels

    CERN Document Server

    Spliethoff, Hartmut

    2010-01-01

    Power Generation from Solid Fuels introduces the different technologies to produce heat and power from solid fossil (hard coal, brown coal) and renewable (biomass, waste) fuels, such as combustion and gasification, steam power plants and combined cycles etc. The book discusses technologies with regard to their efficiency, emissions, operational behavior, residues and costs. Besides proven state of the art processes, the focus is on the potential of new technologies currently under development or demonstration. The main motivation of the book is to explain the technical possibilities for reduci

  5. Pipe rupture incident of Hamaoka Nuclear Power Station Unit-1

    Energy Technology Data Exchange (ETDEWEB)

    Ono, Yushi; Nakagami, Motonori; Hayashi, Haruhisa; Ichikawa, Yoshihiro [Chubu Electric Power Co. Inc., Nagoya (Japan)

    2002-11-01

    At the Hamaoka Nuclear Power Station Unit-1 (540 MWe of electric output; BWR-4 type) of the Chubu Electric Power Co., Ltd., an incident of pipe rupture of residual heat removal system on steam condenser system occurred on November, 2001. This incident gave no effects on outer parts of the station, because safety system apparatuses in the station worked adequately from a standpoint of accidental phenomenon. On the other hand, on its forming processes, as it is no similar case at the nuclear power stations in and out of Japan, to securely carry out countermeasures for preventing a recurrence of the incidence, its cause was striven to elucidate thoroughly. This paper was introduced about contents and results on site surveys, and surveys such as tests, analysis, and so on performed for about a half year after the incident, for preventing a recurrence of similar incidents. (G.K.)

  6. Optimal Selection of Floating Platform for Tidal Current Power Station

    Directory of Open Access Journals (Sweden)

    Fengmei Jing

    2013-06-01

    Full Text Available With continuous development of marine engineering, more and more new structures are used in the exploring of tidal current energy. Three are there different kinds of support structures for tidal current power station, which are sea-bed mounted/gravity based system, pile mounted system and floating moored platform. Comparison with them, the floating mooring system is suit for deep water and the application of which will be widely. In this study, catamaran and semi-submersible as floating platform of tidal current power station are studied. And they are compared with its economic, efficiency of turbine and stability of station. It is found that the catamaran is optimal choice. Based on basic ship theory and using software MOSES, the stability of Catamaran tidal current power station is also calculated. The research of this study is significant and it will be as the reference for the future study.

  7. 75 FR 33366 - Exelon Generation Company, LLC; Oyster Creek Nuclear Generating Station; Notice of Withdrawal of...

    Science.gov (United States)

    2010-06-11

    ... COMMISSION Exelon Generation Company, LLC; Oyster Creek Nuclear Generating Station; Notice of Withdrawal of..., application for amendment to Facility Operating License No. DPR-16 for the Oyster Creek Nuclear Generating Station (Oyster Creek), located in Ocean County, New Jersey. The proposed amendment would have revised...

  8. 光伏发电短期功率预测模型与电站监控系统设计%The Short-term Prediction Model of Photovoltaic Grid Power Generation and the Design for Monitoring System of a Power Station

    Institute of Scientific and Technical Information of China (English)

    林嵩

    2016-01-01

    At present, there is a large fluctuation and randomicity in output power of the large-scale photovoltaic (pv) grid power generation system. To accurately predict the output power in order to solve problems of peak regulation and schedule in photovoltaic grid, this paper set up a low cost small meteorological station real-time monitoring the environment parameters such as radiation intensity, temperature, humidity, wind direction, wind speed etc. and a monitoring system to monitor the operation condition of the photovoltaic power station and gather the data of meteorology to apply to the identification of the meteorological conditions and the prediction model of a short-term power in the photovoltaic power generation system of wavelet neural network so as to realize the accurate prediction for an output power in the large-scale photovoltaic (pv) grid power system and it could have an important significance to generate and apply in a large-scale photovoltaic (pv) grid power generation system.%目前大规模光伏并网发电系统的输出功率波动大、随机性强,为准确预测光伏电站的输出功率以解决大规模光伏并网发电给电网造成的调峰、调度等难题。通过开发能实时监测环境辐照强度、温度、湿度、风向、风速等环境参数的低成本小型气象站和光伏电站监控系统来监测光伏电站的运行状况和采集气象与电站输出功率的数据,并应用于气象条件聚类识别和小波神经网络光伏发电系统短期发电功率预测模型上,以实现大规模光伏并网发电系统输出功率的精确预测,对大规模光伏并网发电系统的推广应用具有重要意义。

  9. Selective analysis of power plant operation on the Hudson River with emphasis on the Bowline Point Generating Station. Volume 2. [Multiple impact of power plant once-through cooling systems on fish populations

    Energy Technology Data Exchange (ETDEWEB)

    Barnthouse, L. W.; Cannon, J. B.; Christensen, S. G.

    1977-07-01

    Because of the location of the Bowline, Roseton, and Indian Point power generating facilities in the low-salinity zone of the Hudson estuary, operation of these plants with the present once-through cooling systems will adversely influence the fish populations that use the area for spawning and initial periods of growth and development. Recruitment rates and standing crops of several fish species may be lowered in response to the increased mortality caused by entrainment of nonscreenable eggs and larvae and by impingement of screenable young of the year. Entrainment and impingement data are particularly relevant for assessing which fish species have the greatest potential for being adversely affected by operation of Bowline, Roseton, and Indian Point with once-through cooling. These data from each of these three plants suggest that the six species that merit the greatest consideration are striped bass, white perch, tomcod, alewife, blueback herring, and bay anchovy. Two points of view are available for assessing the relative importance of the fish species in the Hudson River. From the fisheries point of view, the only two species of major importance are striped bass and shad. From the fish-community and ecosystem point of view, the dominant species, as determined by seasonal and regional standing crops (in numbers and biomass per hectare), are the six species most commonly entrained and impinged, namely, striped bass, white perch, tomcod, alewife, blueback herring, and anchovy.

  10. Space Station Freedom power - A reliability, availability, and maintainability assessment of the proposed Space Station Freedom electric power system

    Science.gov (United States)

    Turnquist, S. R.; Twombly, M.; Hoffman, D.

    1989-01-01

    A preliminary reliability, availability, and maintainability (RAM) analysis of the proposed Space Station Freedom electric power system (EPS) was performed using the unit reliability, availability, and maintainability (UNIRAM) analysis methodology. Orbital replacement units (ORUs) having the most significant impact on EPS availability measures were identified. Also, the sensitivity of the EPS to variations in ORU RAM data was evaluated for each ORU. Estimates were made of average EPS power output levels and availability of power to the core area of the space station. The results of assessments of the availability of EPS power and power to load distribution points in the space stations are given. Some highlights of continuing studies being performed to understand EPS availability considerations are presented.

  11. Power Factor Improvement for Pumping Stations using Capacitor Banks

    Science.gov (United States)

    Mohamad, M. M.; Abd El-gawad, Amal F.; Ramadan, H. S.

    2016-10-01

    One of the fundamental problems affects the performance of pumping stations is its relative high operational cost. As three-phase induction motors are the main prime mover of pumping stations and considered the most widely used electrical motors due to their reliability, ease of maintenance. However, its major problem is the low power factor which results in high electric energy consumption. Energy will be saved when power factor is improved. The main objective of this paper is studying the power factor improvement in El sadaa Pumping Station because of its low operating efficiency which goes from 20 % to 25 %and calculating penalty, ponus and savings in each cases. The correction is achieved by the addition of capacitor banks in parallel with the connected motor circuits and can be applied to the starter, applied at the switchboard or the distribution panel. A model of this station is created using MatlabTM Simulink. Then the determination of induction motor parameters is performed. The station model is discussed. From the simulation results, the power factor enhancement of the pumping station is highlighted.

  12. Analysis of the Use of Wind Energy to Supplement the Power Needs at McMurdo Station and Amundsen-Scott South Pole Station, Antarctica (Poster)

    Energy Technology Data Exchange (ETDEWEB)

    Baring-Gould, E. I.; Robichaud, R.; McLain, K.

    2005-05-01

    This poster summarizes the analysis of the inclusion of wind-driven power generation technology into the existing diesel power plants at two U.S. Antarctic research stations, McMurdo and Amundsen-Scott South Pole Station. Staff at the U.S. Department of Energy's National Renewable Energy Laboratory (NREL) conducted the analysis. Available data were obtained on the wind resources, power plant conditions, load, and component cost. We then used NREL's Hybrid2 power system modeling software to analyze the potential and cost of using wind turbine generators at the two aforementioned facilities.

  13. Power system monitoring and source control of the Space Station Freedom DC power system testbed

    Science.gov (United States)

    Kimnach, Greg L.; Baez, Anastacio N.

    1992-01-01

    Unlike a terrestrial electric utility which can purchase power from a neighboring utility, the Space Station Freedom (SSF) has strictly limited energy resources; as a result, source control, system monitoring, system protection, and load management are essential to the safe and efficient operation of the SSF Electric Power System (EPS). These functions are being evaluated in the DC Power Management and Distribution (PMAD) Testbed which NASA LeRC has developed at the Power System Facility (PSF) located in Cleveland, Ohio. The testbed is an ideal platform to develop, integrate, and verify power system monitoring and control algorithms. State Estimation (SE) is a monitoring tool used extensively in terrestrial electric utilities to ensure safe power system operation. It uses redundant system information to calculate the actual state of the EPS, to isolate faulty sensors, to determine source operating points, to verify faults detected by subsidiary controllers, and to identify high impedance faults. Source control and monitoring safeguard the power generation and storage subsystems and ensure that the power system operates within safe limits while satisfying user demands with minimal interruptions. System monitoring functions, in coordination with hardware implemented schemes, provide for a complete fault protection system. The objective of this paper is to overview the development and integration of the state estimator and the source control algorithms.

  14. Physics Experiments at the Agesta Power Station

    Energy Technology Data Exchange (ETDEWEB)

    Apelqvist, G. [State Power Board, Stockholm (Sweden); Bliselius, P. Aa.; Blomberg, P.E.; Jonsson, E.; Aakerhielm, F. [AB Atomenergi, Nykoeping (Sweden)

    1966-09-15

    Part A. Dynamic measurements have been performed at the Aagesta reactor at power levels from 0.3 to 65 MW(th). The purposes of the experiments have been both to develop experimental methods and equipment for the dynamic studies and to measure the dynamic characteristics of the reactor in order to check the dynamic model. The experiments have been performed with four different perturbation functions: trapezoidal and step functions and two types of periodic multifrequency signals. Perturbations were introduced in the reactivity and in the load. The recordings were made of the responses of nuclear power, coolant inlet and outlet temperature and control rod position. The results are presented as step responses and transfer functions (Bode diagrams). Inmost cases the relative accuracy is {+-} 0.5 dB in amplitude and {+-} 5 deg in phase. The results from the experiments in general show rather good agreement with the results obtained from a dynamic model, which successively has been improved. Experience on reactor noise analysis based on measurements in the Agesta power reactor is discussed. It is shown that the noise measurements have given complementary dynamic information of the reactor. Part B. Static measurements of the physics parameters in the Agesta reactor are carried out to confirm theoretical methods for reactor calculations and to form a good basis for safe operation of the reactor. The reactivity worth of groups of control rods are determined with different methods and compared with calculations with the three-dimensional code HETERO. The excess reactivity as a function of burn up is obtained from the control rod positions. The temperature coefficient of the moderator is measured by lowering the moderator temperature at constant power and observing the change in control rod insertion. As burn up increases the experiments are repeated in order to follow the changes in the coefficient. The xenon poisoning effects are measured by changing the power level and

  15. Magnetic sensing for microstructural assessment of power station steels: Magnetic Barkhausen noise and minor loop measurements

    Science.gov (United States)

    Wilson, J. W.; Karimian, N.; Yin, W.; Liu, J.; Davis, C. L.; Peyton, A. J.

    2013-06-01

    There are currently no techniques available to monitor the microstructural condition of power station steel components in-service (at elevated temperatures). Electromagnetic (EM) inspection methods have the potential to provide a solution to this problem. Tests have been carried out on power generation steel (P9 and T22) samples with different microstructural states using major and minor B-H loop measurements and correlations established between EM properties and material properties such as Vickers hardness. These correlations will be used to develop a field deployable tool for the quantification of degradation in power station steels.

  16. Efforts toward enhancing seismic safety at Kashiwazaki Kariwa nuclear power station

    Energy Technology Data Exchange (ETDEWEB)

    Yamashita, Kazuhiko

    2010-09-15

    Kashiwazaki-Kariwa Nuclear Power Station, 8212MW, was struck by M6.8 quakes in July 2007. TEPCO has steadily been conducting restoration and post-earthquake equipment integrity assessment, aiming to make it a disaster-resistant power station. 2 units among 7 resumed commercial operation by June 2010. This earthquake has provided a great deal of knowledge and information useful for nuclear safety improvement. It has also served as a valuable reference for the IAEA in developing earthquake-related guidelines. TEPCO would like to share the knowledge and information thereby contributing to improving the safety of nuclear power generation. We will introduce some of our activities.

  17. Improving energy performance power station of ship with integrated electric propulsion

    Directory of Open Access Journals (Sweden)

    Dar’enkov Andrey

    2017-01-01

    Full Text Available The article presents the method of calculating the power plant fuel consumption on the basis of diesel-generating installation (DGI with variable speed for ships with integrated electric propulsion. Application DGI with variable speed allows saving fuel and therefore reducing harmful emissions into the atmosphere. In the paper calculated the fuel efficiency of unified power station on the basis of a variable speed DGI power of 1000 kW.

  18. Small proton exchange membrane fuel cell power station by using bio-hydrogen

    Institute of Scientific and Technical Information of China (English)

    刘志祥; 毛宗强; 王诚; 任南琪

    2006-01-01

    In fermentative organic waste water treatment process, there was hydrogen as a by-product. After some purification,there was about 50% ~ 70% hydrogen in the bio-gas, which could be utilized for electricity generation with fuel cell. Half a year ago, joint experiments between biological hydrogen production in Harbin Institute of Technology (HIT) and proton exchange membrane fuel cell (PEMFC) power station in Tsinghua University were conducted for electricity generation with bio-hydrogen from the pilot plant in HIT. The results proved the feasibility of the bio-hydrogen as a by-product utilization with PEMFC power station and revealed some problems of fuel cell power station for this application.

  19. Wind Power Generation Design Considerations.

    Science.gov (United States)

    1984-12-01

    sites. have low starting torques, operate at high tip-to- wind speeds, and generate high power output per turbine weight. 5 The Savonius rotor operates...DISTRIBUTION 4 I o ....................................... . . . e . * * TABLES Number Page I Wind Turbine Characteristics II 0- 2 Maximum Economic Life II 3...Ratio of Blade Tip Speed to Wind Speed 10 4 Interference with Microwave and TV Reception by Wind Turbines 13 5 Typical Flow Patterns Over Two

  20. Electrical calculations and guidelines for generating station and industrial plants

    CERN Document Server

    Baker, Thomas E

    2011-01-01

    ""This is really a practical, hands-on book for the working engineer."" --Phillip Wheeler, former Southern California Edison supervising electrical apparatus engineer and regional IEEE PES/IAS leader Electrical Calculations and Guidelines for Generating Stations and Industrial Plants: Covers, in a single reference, more than 160 calculations for the design, operation, and maintenance support of generating stations and industrial facilities Is supported by inexpensive, simple-to-use software that automates presented calculations Explores electrical theory at the atomic level: How can AC current

  1. Design of Three Phase Solar-Based 4.5kw Ac Power Inverter Station

    Directory of Open Access Journals (Sweden)

    Dr.J.C. Onuegbu

    2013-07-01

    Full Text Available The design model of a 4.50Kilowatt, 3-phase, 50 hertz solar-based power generating station was examined by the paper. The power station is a dual source input generating station using 8 series connected 100A, 12V batteries per phase as backup, the solar panels being the main frame. An inverter of 12Volt direct current input voltage was incorporated to supply an output of 3-phase, 220Volts and 50 hertz alternating current. A charging circuit was installed to monitor charging level and to preserve the accumulator’s life span. The paper also looked into the solar-based power station component design model. The batteries therein are back-up and the system will ensure 24-hours reliable power supply. The setup has a normally closed switching relay ready to pickup the auxiliary battery supply within a few milliseconds after the solar source voltage drops below a stipulated level. The three phase a.c. voltage was achieved using standby on-line circuit with cascaded 741-based flip-flop at the base of the transistor drivers of the 3-phase power transformer. This model circuit reduced the load on each phase winding and facilitated reliable and uninterruptible power supply. The delta-wyeconnected transformer will guarantee proper phase shift of 120 degrees that will emulate alternating current voltage similar to the conventional generator voltage.

  2. Rankine engine solar power generation. II - The power generation module

    Science.gov (United States)

    Batton, W. D.; Barber, R. E.

    1981-11-01

    The characteristics and performance of a solar flat plate collector powered low temperature power generation module (PGM) funded by NASA are described. The PGM uses a halogen refrigerant as a working fluid, which is pumped from a reservoir to a chamber where it is heated by exchangers filled with an ethylene-glycol fluid which has gained thermal energy from a collector array. The heated refrigerant is allowed to expand through turbine blades and exits through a regenerative heater to condensation into the original well. The PGM was built mainly from off-the-shelf components, except for the turbo-gearbox, which was fabricated specifically for the PGM and attains the design goal of 80% efficiency, producing 13.8 kW at the design point. The components and controls are detailed, including start-up and shutdown, and safety procedures. The testing program is outlined, and 6000 hours of operating experience has resulted in a 7.2% efficiency.

  3. Bioremediation for coal-fired power stations using macroalgae.

    Science.gov (United States)

    Roberts, David A; Paul, Nicholas A; Bird, Michael I; de Nys, Rocky

    2015-04-15

    Macroalgae are a productive resource that can be cultured in metal-contaminated waste water for bioremediation but there have been no demonstrations of this biotechnology integrated with industry. Coal-fired power production is a water-limited industry that requires novel approaches to waste water treatment and recycling. In this study, a freshwater macroalga (genus Oedogonium) was cultivated in contaminated ash water amended with flue gas (containing 20% CO₂) at an Australian coal-fired power station. The continuous process of macroalgal growth and intracellular metal sequestration reduced the concentrations of all metals in the treated ash water. Predictive modelling shows that the power station could feasibly achieve zero discharge of most regulated metals (Al, As, Cd, Cr, Cu, Ni, and Zn) in waste water by using the ash water dam for bioremediation with algal cultivation ponds rather than storage of ash water. Slow pyrolysis of the cultivated algae immobilised the accumulated metals in a recalcitrant C-rich biochar. While the algal biochar had higher total metal concentrations than the algae feedstock, the biochar had very low concentrations of leachable metals and therefore has potential for use as an ameliorant for low-fertility soils. This study demonstrates a bioremediation technology at a large scale for a water-limited industry that could be implemented at new or existing power stations, or during the decommissioning of older power stations.

  4. Intermediate photovoltaic system application experiment operational performance report. Volume 13. For Newman Power Station, El Paso, Texas

    Energy Technology Data Exchange (ETDEWEB)

    1982-09-01

    Presented are the data accumulated during June at the intermediate photovoltaic project at Newman Power Station, El Paso, Texas. Generated energy and environmental (weather) data are presented graphically. Explanations of irregularities not attributable to weather are provided.

  5. Efficiency of Modern Power Plants of Thermal Power Stations

    Directory of Open Access Journals (Sweden)

    B. V. Yakovlev

    2007-01-01

    Full Text Available The paper considers efficiency and prospects in development of different types of fossil-fuel power plants – gas turbine, steam turbine and combined (gas and steam cycles.The paper provides information on plant selection, fuel consumption, specific output cost. It describes main advantages of various power plants.

  6. Safety design of next generation SUI of CANDU stations

    Energy Technology Data Exchange (ETDEWEB)

    Nasimi, Elnara [Faculty of Energy Systems and Nuclear Science, University of Ontario Institute of Technology, 2000 Simcoe St. N., Oshawa, L1H 7K4 ON (Canada); Gabbar, Hossam A., E-mail: hossam.gabbar@uoit.ca [Faculty of Energy Systems and Nuclear Science, University of Ontario Institute of Technology, 2000 Simcoe St. N., Oshawa, L1H 7K4 ON (Canada)

    2013-01-15

    Highlights: Black-Right-Pointing-Pointer Review of current SUI technologies and challenges. Black-Right-Pointing-Pointer Propose a new type of SUI detectors. Black-Right-Pointing-Pointer Propose a new SUI system architecture and layout. Black-Right-Pointing-Pointer Propose implementation procedure for SUI with reduced risks. - Abstract: Due to the age and operating experience of Nuclear Power Plants, equipment ageing and obsolescence has become one of the main challenges that need to be resolved for all systems, structures and components in order to ensure a safe and reliable production of energy. This paper summarizes the research into a methodology for modernization of Start-Up Instrumentation (SUI), both in-core and Control Room equipment, using a new generation of detectors and cables in order to manage obsolescence. The main objective of this research is to develop a new systematic approach to SUI installation/replacement procedure development and optimization. Although some additional features, such as real-time data monitoring and storage/archiving solutions for SUI systems are also examined to take full advantage of today's digital technology, the objectives of this study do not include detailed parametrical studies of detector or system performance. Instead, a number of technological, operational and maintenance issues associated with Start-Up Instrumentation systems at Nuclear Power Plants (NPPs) will be identified and a structured approach for developing a replacement/installation procedure that can be standardized and used across all of the domestic CANDU (Canadian Deuterium Uranium) stations is proposed.

  7. Mercury emissions from South Africa’s coal-fired power stations

    Directory of Open Access Journals (Sweden)

    Belinda L. Garnham

    2016-12-01

    Full Text Available Mercury is a persistent and toxic substance that can be bio-accumulated in the food chain. Natural and anthropogenic sources contribute to the mercury emitted in the atmosphere. Eskom’s coal-fired power stations in South Africa contributed just under 93% of the total electricity produced in 2015 (Eskom 2016. Trace amounts of mercury can be found in coal, mostly combined with sulphur, and can be released into the atmosphere upon combustion. Coal-fired electricity generation plants are the highest contributors to mercury emissions in South Africa. A major factor affecting the amount of mercury emitted into the atmosphere is the type and efficiency of emission abatement equipment at a power station. Eskom employs particulate emission control technology at all its coal-fired power stations, and new power stations will also have sulphur dioxide abatement technology. A co-beneficial reduction of mercury emissions exists as a result of emission control technology. The amount of mercury emitted from each of Eskom’s coal-fired power stations is calculated, based on the amount of coal burnt and the mercury content in the coal. Emission Reduction Factors (ERF’s from two sources are taken into consideration to reflect the co-benefit received from the emission control technologies at the stations. Between 17 and 23 tons of mercury is calculated to have been emitted from Eskom’s coal-fired power stations in 2015. On completion of Eskom’s emission reduction plan, which includes fabric filter plant retrofits at two and a half stations and a flue gas desulphurisation retrofit at one power station, total mercury emissions from the fleet will potentially be reduced by 6-13% by 2026 relative to the baseline. Mercury emission reduction is perhaps currently not the most pressing air quality problem in South Africa. While the focus should then be on reducing emissions of other pollutants which have a greater impact on human health, mercury emission reduction

  8. 77 FR 35080 - Entergy Nuclear Operations, Inc., Pilgrim Nuclear Power Station; Record of Decision and Issuance...

    Science.gov (United States)

    2012-06-12

    ... fossil fuel generation, renewable energy sources, demand-side measures such as energy conservation, and... From the Federal Register Online via the Government Publishing Office NUCLEAR REGULATORY COMMISSION Entergy Nuclear Operations, Inc., Pilgrim Nuclear Power Station; Record of Decision and Issuance...

  9. FUEL CELL OPERATION ON LANDFILL GAS AT PENROSE POWER STATION

    Science.gov (United States)

    This demonstration test successfully demonstrated operation of a commercial phosphoric acid fuel cell (FC) on landfill gas (LG) at the Penrose Power Station in Sun Valley, CA. Demonstration output included operation up to 137 kW; 37.1% efficiency at 120 kW; exceptionally low sec...

  10. Wind wheel electric power generator

    Science.gov (United States)

    Kaufman, J. W. (Inventor)

    1980-01-01

    Wind wheel electric power generator apparatus includes a housing rotatably mounted upon a vertical support column. Primary and auxiliary funnel-type, venturi ducts are fixed onto the housing for capturing wind currents and conducting to a bladed wheel adapted to be operatively connected with the generator apparatus. Additional air flows are also conducted onto the bladed wheel; all of the air flows positively effecting rotation of the wheel in a cumulative manner. The auxiliary ducts are disposed at an acute angle with respect to the longitudinal axis of the housing, and this feature, together with the rotatability of the housing and the ducts, permits capture of wind currents within a variable directional range.

  11. Magnetic sensing for microstructural assessment of power station steels: Magnetic Barkhausen noise and minor loop measurements

    OpenAIRE

    Wilson, JWa; Karimian, N a; Yin, W a; Liu, J. B.; Davis, CLb; Peyton, AJa

    2013-01-01

    There are currently no techniques available to monitor the microstructural condition of power station steel components in-service (at elevated temperatures). Electromagnetic (EM) inspection methods have the potential to provide a solution to this problem. Tests have been carried out on power generation steel (P9 and T22) samples with different microstructural states using major and minor B-H loop measurements and correlations established between EM properties and material properties such as V...

  12. Power Generation from Coal 2010

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    Coal is the biggest single source of energy for electricity production and its share is growing. The efficiency of converting coal into electricity matters: more efficient power plants use less fuel and emit less climate-damaging carbon dioxide. This book explores how efficiency is measured and reported at coal-fired power plants. With many different methods used to express efficiency performance, it is often difficult to compare plants, even before accounting for any fixed constraints such as coal quality and cooling-water temperature. Practical guidelines are presented that allow the efficiency and emissions of any plant to be reported on a common basis and compared against best practice. A global database of plant performance is proposed that would allow under-performing plants to be identified for improvement. Armed with this information, policy makers would be in a better position to monitor and, if necessary, regulate how coal is used for power generation. The tools and techniques described will be of value to anyone with an interest in the more sustainable use of coal.

  13. Tampa Electric Company Polk Power Station IGCC project: Project status

    Energy Technology Data Exchange (ETDEWEB)

    McDaniel, J.E.; Carlson, M.R.; Hurd, R.; Pless, D.E.; Grant, M.D. [Tampa Electric Co., FL (United States)

    1997-12-31

    The Tampa Electric Company Polk Power Station is a nominal 250 MW (net) Integrated Gasification Combined Cycle (IGCC) power plant located to the southeast of Tampa, Florida in Polk County, Florida. This project is being partially funded under the Department of Energy`s Clean Coal Technology Program pursuant to a Round II award. The Polk Power Station uses oxygen-blown, entrained-flow IGCC technology licensed from Texaco Development Corporation to demonstrate significant reductions of SO{sub 2} and NO{sub x} emissions when compared to existing and future conventional coal-fired power plants. In addition, this project demonstrates the technical feasibility of commercial scale IGCC and Hot Gas Clean Up (HGCU) technology. The Polk Power Station achieved ``first fire`` of the gasification system on schedule in mid-July, 1996. Since that time, significant advances have occurred in the operation of the entire IGCC train. This paper addresses the operating experiences which occurred in the start-up and shakedown phase of the plant. Also, with the plant being declared in commercial operation as of September 30, 1996, the paper discusses the challenges encountered in the early phases of commercial operation. Finally, the future plans for improving the reliability and efficiency of the Unit in the first quarter of 1997 and beyond, as well as plans for future alternate fuel test burns, are detailed. The presentation features an up-to-the-minute update on actual performance parameters achieved by the Polk Power Station. These parameters include overall Unit capacity, heat rate, and availability. In addition, the current status of the start-up activities for the HGCU portion of the plant is discussed.

  14. Scheduled Operation of PV Power Station Considering Solar Radiation Forecast Error

    Science.gov (United States)

    Takayama, Satoshi; Hara, Ryoichi; Kita, Hiroyuki; Ito, Takamitsu; Ueda, Yoshinobu; Saito, Yutaka; Takitani, Katsuyuki; Yamaguchi, Koji

    Massive penetration of photovoltaic generation (PV) power stations may cause some serious impacts on a power system operation due to their volatile and unpredictable output. Growth of uncertainty may require larger operating reserve capacity and regulating capacity. Therefore, in order to utilize a PV power station as an alternative for an existing power plant, improvement in controllability and adjustability of station output become very important factor. Purpose of this paper is to develop the scheduled operation technique using a battery system (NAS battery) and the meteorological forecast. The performance of scheduled operation strongly depends on the accuracy of solar radiation forecast. However, the solar radiation forecast contains error. This paper proposes scheduling method and rescheduling method considering the trend of forecast error. More specifically, the forecast error scenario is modeled by means of the clustering analysis of the past actual forecast error. Validity and effectiveness of the proposed method is ascertained through computational simulations using the actual PV generation data monitored at the Wakkanai PV power station and solar radiation forecast data provided by the Japan Weather Association.

  15. Efficient ways for setting up the operation of nuclear power stations in power systems in the base load mode

    Science.gov (United States)

    Aminov, R. Z.; Shkret, A. F.; Burdenkova, E. Yu.; Garievskii, M. V.

    2011-05-01

    The results obtained from studies of efficient ways and methods for organizing the operation of developing nuclear power stations in the base load mode are presented. We also show comparative efficiency of different scenarios for unloading condensing thermal power stations, cogeneration stations, combined-cycle power plants, nuclear power stations, and using off-peak electric energy for electricity-intensive loads: pumped-hydroelectric storage, electric-powered heat supply, and electrolysis of water for producing hydrogen and oxygen.

  16. TEDS Base Station Power Amplifier using Low-Noise Envelope Tracking Power Supply

    DEFF Research Database (Denmark)

    Høyerby, Mikkel Christian Wendelboe; Andersen, Michael A. E.

    2009-01-01

    This paper demonstrates a highly linear and efficient TETRA enhanced data service (TEDS) base-station RF power amplifier (RFPA). Based on the well-known combination of an envelope tracking (ET) power supply and a linear class-A/B RFPA, adequate adjacent channel power ratio (ACPR) and wideband noise...

  17. Future Photovoltaic Power Generation for Space-Based Power Utilities

    Science.gov (United States)

    Bailey, S.; Landis, G.; Raffaelle, R.; Hepp, A.

    2002-01-01

    A recent NASA program, Space Solar Power Exploratory Research and Technology (SERT), investigated the technologies needed to provide cost-competitive ground baseload electrical power from space based solar energy conversion. This goal mandated low cost, light weight gigawatt (GW) power generation. Investment in solar power generation technologies would also benefit high power military, commercial and science missions. These missions are generally those involving solar electric propulsion, surface power systems to sustain an outpost or a permanent colony on the surface of the moon or mars, space based lasers or radar, or as large earth orbiting power stations which can serve as central utilities for other orbiting spacecraft, or as in the SERT program, potentially beaming power to the earth itself. This paper will discuss requirements for the two latter options, the current state of the art of space solar cells, and a variety of both evolving thin film cells as well as new technologies which may impact the future choice of space solar cells for a high power mission application. The space world has primarily transitioned to commercially available III-V (GaInP/GaAs/Ge) cells with 24-26% air mass zero (AMO) efficiencies. Research in the III-V multi-junction solar cells has focused on fabricating either lattice-mismatched materials with optimum stacking bandgaps or new lattice matched materials with optimum bandgaps. In the near term this will yield a 30% commercially available space cell and in the far term possibly a 40% cell. Cost reduction would be achieved if these cells could be grown on a silicon rather than a germanium substrate since the substrate is ~65% of the cell cost or, better yet, on a polyimide or possibly a ceramic substrate. An overview of multi-junction cell characteristics will be presented here. Thin film cells require substantially less material and have promised the advantage of large area, low cost manufacturing. However, space cell requirements

  18. A Potential Transmitter Architecture for Future Generation Green Wireless Base Station

    Directory of Open Access Journals (Sweden)

    Cijvat Ellie

    2009-01-01

    Full Text Available Abstract Current radio frequency power amplifiers in 3G base stations have very high power consumption leading to a hefty cost and negative environmental impact. In this paper, we propose a potential architecture design for future wireless base station. Issues associated with components of the architecture are investigated. The all-digital transmitter architecture uses a combination of envelope elimination and restoration (EER and pulse width modulation (PWM/pulse position modulation (PPM modulation. The performance of this architecture is predicted from the measured output power and efficiency curves of a GaN amplifier. 57% efficiency is obtained for an OFDM signal limited to 8 dB peak to average power ratio. The PWM/PPM drive signal is generated using the improved Cartesian sigma delta techniques. It is shown that an RF oversampling by a factor of four meets the WLAN spectral mask, and WCDMA specification is met by an RF oversampling of sixteen.

  19. A Potential Transmitter Architecture for Future Generation Green Wireless Base Station

    Directory of Open Access Journals (Sweden)

    Mike Faulkner

    2009-01-01

    Full Text Available Current radio frequency power amplifiers in 3G base stations have very high power consumption leading to a hefty cost and negative environmental impact. In this paper, we propose a potential architecture design for future wireless base station. Issues associated with components of the architecture are investigated. The all-digital transmitter architecture uses a combination of envelope elimination and restoration (EER and pulse width modulation (PWM/pulse position modulation (PPM modulation. The performance of this architecture is predicted from the measured output power and efficiency curves of a GaN amplifier. 57% efficiency is obtained for an OFDM signal limited to 8 dB peak to average power ratio. The PWM/PPM drive signal is generated using the improved Cartesian sigma delta techniques. It is shown that an RF oversampling by a factor of four meets the WLAN spectral mask, and WCDMA specification is met by an RF oversampling of sixteen.

  20. Connecticut Biodiesel Power Generation Project

    Energy Technology Data Exchange (ETDEWEB)

    Grannis, Lee [Greater New Haven Clean Cities Coalition, Bethany, CT (United States); York, Carla R. [Greater New Haven Clean Cities Coalition, Bethany, CT (United States)

    2010-10-31

    Sabre will continue support of the emissions equipment and VARS issues to ensure all are resolved and the system is functioning as expected. The remote data collection to become more automated. Final project reports for data collection and system performance to be generated. Sabre continued to support the emissions equipment and VARS issues to ensure all are resolved and the system is functioning as expected. The remote data collection became more automated. Final project reports for data collection and system performance were generated and are part of this final report. Some Systems Sensors were replaced due to a lightning strike. Sample data charts are shown at the end of the report. During the project, Sabre Engineering provided support to the project team with regarding to troubleshooting technical issues and system integration with the local power utility company. The resulting lessons learned through Sabre’s participation in the project have been valuable to the integrity of the data collected as well as in providing BioPur Light & Power valuable insights into future operations and planning for possible expansion. The system monitoring and data collection system has been operating as designed and continues to provide relevant information to the system operators. The information routinely gathered automatically by the system also contributes to the REN and REC validations which are required to secure credit for these items. During the quarter, the remaining work on the operations and safety manual were completed and released for publication after screen shots were verified. The goal of this effort to provide an accurate set of precautions and procedures for the technology system that can be replicated to other similar system.

  1. Integration of stochastic generation in power systems

    NARCIS (Netherlands)

    Papaefthymiou, G.

    2007-01-01

    Stochastic Generation is the electrical power production by the use of an uncontrollable prime energy mover, corresponding mainly to renewable energy sources. For the large-scale integration of stochastic generation in power systems, methods are necessary for the modeling of power generation

  2. Integration of stochastic generation in power systems

    NARCIS (Netherlands)

    Papaefthymiou, G.

    2007-01-01

    Stochastic Generation is the electrical power production by the use of an uncontrollable prime energy mover, corresponding mainly to renewable energy sources. For the large-scale integration of stochastic generation in power systems, methods are necessary for the modeling of power generation uncerta

  3. Integration of stochastic generation in power systems

    NARCIS (Netherlands)

    Papaefthymiou, G.

    2007-01-01

    Stochastic Generation is the electrical power production by the use of an uncontrollable prime energy mover, corresponding mainly to renewable energy sources. For the large-scale integration of stochastic generation in power systems, methods are necessary for the modeling of power generation uncerta

  4. Chapter 11: Marine and Hydrokinetic Power Generation and Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Muljadi, Eduard; Yu, Yi-Hsiang

    2017-05-18

    Marine and hydrokinetic (MHK) power generation is a relatively new type of renewable generation. Predecessors such as wind power generation, hydropower plant generation, geothermal generation, photovoltaic generation, and solar thermal generation have gained a lot of attention because of their successful implementation. The successful integration of renewable generation into the electric power grid has energized the power system global communities to take the lessons learned, innovations, and market structure to focus on the large potential of MHK to also contribute to the pool of renewable energy generation. This chapter covers the broad spectrum of MHK generation. The state-of-the-art power takeoff methods will be discussed. Types of electrical generators will be presented, and the options for implementation will be presented.

  5. Study of wet blasting of components in nuclear power stations

    Energy Technology Data Exchange (ETDEWEB)

    Hall, J

    1999-12-01

    This report looks at the method of wet blasting radioactive components in nuclear power stations. The wet blaster uses pearl shaped glass beads with the dimensions of 150-250 {mu}m mixed with water as blasting media. The improved design, providing outer operator's positions with proper radiation protection and more efficient blasting equipment has resulted in a lesser dose taken by the operators. The main reason to decontaminate components in nuclear power plants is to enable service on these components. On components like valves, pump shafts, pipes etc. oxides form and bind radiation. These components are normally situated at some distance from the reactor core and will mainly suffer from radiation from so called activation products. When a component is to be decontaminated it can be decontaminated to a radioactive level where it will be declassified. This report has found levels ranging from 150-1000 Bq/kg allowing declassification of radioactive materials.This difference is found between different countries and different organisations. The report also looks at the levels of waste generated using wet blasting. This is done by tracking the contamination to determine where it collects. It is either collected in the water treatment plant or collected in the blasting media. At Barsebaeck the waste levels, from de-contaminating nearly 800 components in one year, results in a waste volume of about 0,250 m{sup 3}. This waste consists of low and medium level waste and will cost about 3 600 EURO to store. The conclusions of the report are that wet blasting is an indispensable way to treat contaminated components in modern nuclear power plants. The wet blasting equipment can be improved by using a robot enabling the operators to remotely treat components from the outer operator's positions. There they will benefit from better radiation protection thus further reduce their taken dose. The wet blasting equipment could also be used to better control the levels of

  6. Floating tidal power station. Schwimmkoerper-Gezeiten-Kraftwerk

    Energy Technology Data Exchange (ETDEWEB)

    Muenzner, H.J.

    1987-03-19

    This is a floating tidal power station, characterized by the fact that water stores are lifted by the tide by float lifts in the form of docks; on the flood tide they are supported mechanically at the height reached by support members or hydraulically, until after several tides a favourable and economically justifiable height for the technical efficiency of water turbines is reached by the first water store. The stored water is then released through water turbines to obtain energy. This emptied water store is then lowered to the initial position with the support members with the aid of emptied float lifts built like ship's lifting equipment (which only require a slight movement of a weight for lifting and lowering). The filling and lifting is then repeated. During this regeneration, the energy is obtained from the next water store. A whole floating tidal power station consists of as many water stores as are required for uninterrupted continuous operation.

  7. FLAME MONITORING IN POWER STATION BOILERS USING IMAGE PROCESSING

    OpenAIRE

    K Sujatha; VENMATHI, M.; N. Pappa

    2012-01-01

    Combustion quality in power station boilers plays an important role in minimizing the flue gas emissions. In the present work various intelligent schemes to infer the flue gas emissions by monitoring the flame colour at the furnace of the boiler are proposed here. Flame image monitoring involves capturing the flame video over a period of time with the measurement of various parameters like Carbon dioxide (CO2), excess oxygen (O2), Nitrogen dioxide (NOx), Sulphur dioxide (SOx) and Carbon monox...

  8. Legionella control in power station cooling towers using oxidising biocides

    Energy Technology Data Exchange (ETDEWEB)

    Sailer, Christian; Rawlinson, Julia; Killeen, Paul [Ecolab PTY LTD, Ascot, WA (Australia)

    2009-02-15

    Power stations have used oxidising biocides such as chlorine or bromine for many years to control microbial growth in their cooling towers. In this paper Ecolab trademark looks at the direct effect halogen concentration has on Legionella populations in order to determine the most effective halogenation rate required to ensure that the site key performance indicator (KPI) of < 100 colony-forming units (cfu) per mL can be maintained. (orig.)

  9. 47 CFR 74.707 - Low power TV and TV translator station protection.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Low power TV and TV translator station... SERVICES Low Power TV, TV Translator, and TV Booster Stations § 74.707 Low power TV and TV translator station protection. (a)(1) A low power TV or TV translator will be protected from interference from...

  10. Station normal : the power of the Stave River

    Energy Technology Data Exchange (ETDEWEB)

    Stanley, M.; Wilson, H. [BC Hydro, Vancouver, BC (Canada)

    2001-07-01

    This book documented the history of power development along the Stave River and Stave Falls in British Columbia. The book was compiled from memories of employees and retired employees who helped to build the power station along the Stave River. The book provided details of the technical achievements accomplished during the construction of the hydro-electric project, and described the roles and functions of BC Hydro workers at the plant. The book also chronicled the project's growth over time, and discussed its impact on communities in the region. The book included over 100 photographs, as well as a chronology. refs., tabs., figs.

  11. 基于TOPSIS模型的火力发电企业电煤供应商选择评价研究%Research on the Generating Coal Supplier Selection and Evaluation of Thermal Power Station Based on TOPSIS

    Institute of Scientific and Technical Information of China (English)

    李小辉

    2012-01-01

    The evaluation index system, which helps to select a supplier of coal, is built from cost factors, quality factors and the arrival factor, including eight indicators, standard coal price, heating quantity of constant capacity on low position as received coal, ash content, water content, total sulphur content, qualified rate, on-time delivery, actual weight rate. Using the AHP to determine the subjective weights, entropy method to determine the objective weight, get combination weight, and using TOPSIS model of a thermal power station's 19 coal suppliers to make the evaluation and choice. How to improve competitiveness of coal suppliers, and how to improve level on managing coal suppliers of thermal power station are proposed.%针对火力发电企业电煤供应商的特点,从成本因素、质量因素、到货因素三个方面,建立了由入厂标准煤单价、收到基恒容低位发热量、空气干燥基灰分、全水分、全硫、合格率、准时交货率、实收重量率8个指标构成的指标体系.采用了层次分析法确定的主观权重、熵权法确定客观权重,得到主观权重和客观权重相结合的组合权重,并使用TOPSIS模型对某火力发电企业的19个电煤供应商做出了评价和选择,对电煤供应商怎样提高竞争力以及火力发电企业对电煤供应商进行管理的重点内容提出了建议.

  12. Application of ORC power station to increase electric power of gas compression ignition engine

    Directory of Open Access Journals (Sweden)

    Mocarski Szymon

    2017-01-01

    Full Text Available The paper presents the calculation results of efficiency of the subcritical low temperature ORC power station powered by waste heat resulting from the process of cooling a stationary compression ignition engine. The source of heat to supply the ORC power station is the heat in a form of water jet cooling the engine at a temperature of 92°C, and the exhaust gas stream at a temperature of 420°C. The study considers three variants of systems with the ORC power stations with different ways of using heat source. The first variant assumes using just engine cooling water to power the ORC station. In the second variant the ORC system is powered solely by a heat flux from the combustion gases by means of an intermediary medium - thermal oil, while the third variant provides the simultaneous management of both heat fluxes to heat the water stream as a source of power supply to the ORC station. The calculations were made for the eight working media belonging both to groups of so-called dry media (R218, R1234yf, R227ea and wet media (R32, R161, R152a, R134a, R22.

  13. Observations of Earth space by self-powered stations in Antarctica.

    Science.gov (United States)

    Mende, S B; Rachelson, W; Sterling, R; Frey, H U; Harris, S E; McBride, S; Rosenberg, T J; Detrick, D; Doolittle, J L; Engebretson, M; Inan, U; Labelle, J W; Lanzerotti, L J; Weatherwax, A T

    2009-12-01

    Coupling of the solar wind to the Earth magnetosphere/ionosphere is primarily through the high latitude regions, and there are distinct advantages in making remote sensing observations of these regions with a network of ground-based observatories over other techniques. The Antarctic continent is ideally situated for such a network, especially for optical studies, because the larger offset between geographic and geomagnetic poles in the south enables optical observations at a larger range of magnetic latitudes during the winter darkness. The greatest challenge for such ground-based observations is the generation of power and heat for a sizable ground station that can accommodate an optical imaging instrument. Under the sponsorship of the National Science Foundation, we have developed suitable automatic observing platforms, the Automatic Geophysical Observatories (AGOs) for a network of six autonomous stations on the Antarctic plateau. Each station housed a suite of science instruments including a dual wavelength intensified all-sky camera that records the auroral activity, an imaging riometer, fluxgate and search-coil magnetometers, and ELF/VLF and LM/MF/HF receivers. Originally these stations were powered by propane fuelled thermoelectric generators with the fuel delivered to the site each Antarctic summer. A by-product of this power generation was a large amount of useful heat, which was applied to maintain the operating temperature of the electronics in the stations. Although a reasonable degree of reliability was achieved with these stations, the high cost of the fuel air lift and some remaining technical issues necessitated the development of a different type of power unit. In the second phase of the project we have developed a power generation system using renewable energy that can operate automatically in the Antarctic winter. The most reliable power system consists of a type of wind turbine using a simple permanent magnet rotor and a new type of power

  14. Observations of Earth space by self-powered stations in Antarctica

    Science.gov (United States)

    Mende, S. B.; Rachelson, W.; Sterling, R.; Frey, H. U.; Harris, S. E.; McBride, S.; Rosenberg, T. J.; Detrick, D.; Doolittle, J. L.; Engebretson, M.; Inan, U.; Labelle, J. W.; Lanzerotti, L. J.; Weatherwax, A. T.

    2009-12-01

    Coupling of the solar wind to the Earth magnetosphere/ionosphere is primarily through the high latitude regions, and there are distinct advantages in making remote sensing observations of these regions with a network of ground-based observatories over other techniques. The Antarctic continent is ideally situated for such a network, especially for optical studies, because the larger offset between geographic and geomagnetic poles in the south enables optical observations at a larger range of magnetic latitudes during the winter darkness. The greatest challenge for such ground-based observations is the generation of power and heat for a sizable ground station that can accommodate an optical imaging instrument. Under the sponsorship of the National Science Foundation, we have developed suitable automatic observing platforms, the Automatic Geophysical Observatories (AGOs) for a network of six autonomous stations on the Antarctic plateau. Each station housed a suite of science instruments including a dual wavelength intensified all-sky camera that records the auroral activity, an imaging riometer, fluxgate and search-coil magnetometers, and ELF/VLF and LM/MF/HF receivers. Originally these stations were powered by propane fuelled thermoelectric generators with the fuel delivered to the site each Antarctic summer. A by-product of this power generation was a large amount of useful heat, which was applied to maintain the operating temperature of the electronics in the stations. Although a reasonable degree of reliability was achieved with these stations, the high cost of the fuel air lift and some remaining technical issues necessitated the development of a different type of power unit. In the second phase of the project we have developed a power generation system using renewable energy that can operate automatically in the Antarctic winter. The most reliable power system consists of a type of wind turbine using a simple permanent magnet rotor and a new type of power

  15. Renewable Power for the Swedish Antarctic Station Wasa

    Energy Technology Data Exchange (ETDEWEB)

    Henryson, Mattias; Svensson, Martin [Royal Inst. of Technology, Stockholm (Sweden). Dept. of Energy Technology

    2004-07-01

    As the debate on fossil fuel usage in Antarctica has been more and more highlighted, the participating countries, bound by the Antarctic treaty, have encouraged changes in their power systems. Some of the stations or research stations in Antarctica are very large, constituting smaller towns with all conceivable service, and hence very energy consuming. Focus is put on partly or completely replacing fossil fuelled energy with renewable energy such as wind and solar power, supported by either batteries or fuel cells. Today there are a number of both successful and unsuccessful installations of renewable energy systems in Antarctica. Implementing a power system in remote areas where continuous access is limited comprises great technical challenges and Antarctica fulfils by all means every difficulty involved. The objective of this thesis is to propose ways of meeting power and energy demands for the Swedish Antarctic Research Program (SWEDARP) under the strict environmental legislations by as far as possible utilising the free renewable energy resources. A new power system is aimed at supplying 1 kW of electric power for continuous monitoring and collection of research data. The station is manned for three months, which implies a need of an autonomous system with high reliability. The following was based on a technical viability and economical feasibility study. Results are based upon analyses and computer simulations (HOMER) on how each fundamental system component is expected to work in the harsh climate conditions found at the station Wasa in Antarctica. It was found that wind power has the greatest potential as primary energy source in Antarctica. Supported by appropriate batteries, a reliable and in many ways feasible system can be obtained. Nevertheless, for the chosen techniques to endure the harsh climate conditions, sufficient modifications and developments of each component are needed. Based on the analyses the survey results in a proposal for a final system

  16. Tampa Electric Company`s Polk Power Station Integrated Gasification Combined Cycle Project

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, S.D.; Shafer, J.R.

    1994-12-31

    Tampa Electric Company (TEC) is in the construction phase for the new Polk Power Station, Unit {number_sign}1. This will be the first unit at a new site and will use Integrated Gasification Combined Cycle (IGCC) technology for power generation. The unit will utilize oxygen-blown entrained-flow coal gasification, along with combined cycle technology, to provide nominal net 26OMW of generation. As part of the environmental features of this process, the sulfur species in the coal will be recovered as a commercial grade sulfuric acid by-product. The sulfur will be removed from the synthesis gas utilizing a cold gas clean-up system (CGCU).

  17. MHD-steam thermal power plant electrical stations with zero stack emission

    Energy Technology Data Exchange (ETDEWEB)

    Borghi, C.A.; Botti, M.; Ribani, P.L. [Univ. of Bologna (Italy)

    1994-12-31

    In the present work a system study of a combined cycle MHD-steam thermal power plant electrical station with zero stack emission through recirculation of CO{sub 2}, is presented. The design of the MHD generator of the topper is done by means of a quasi-one-dimensional optimisation model. The thermodynamic of the combustion gas, typical of this cycle, is considered. The technology of the components is conventional. An overall efficiency larger than 41% for power plants with electrical power inputs above 600 MWe, are obtained.

  18. Operation and maintenance of thermal power stations best practices and health monitoring

    CERN Document Server

    Chanda, Pradip

    2016-01-01

    This book illustrates operation and maintenance practices/guidelines for economic generation and managing health of a thermal power generator beyond its regulatory life. The book provides knowledge for professionals managing power station operations, through its unique approach to chemical analysis of water, steam, oil etc. to identify malfunctioning/defects in equipment/systems much before the physical manifestation of the problem. The book also contains a detailed procedure for conducting performance evaluation tests on different equipment, and for analyzing test results for predicting maintenance requirements, which has lent a new dimension to power systems operation and maintenance practices. A number of real life case studies also enrich the book. This book will prove particularly useful to power systems operations professionals in the developing economies, and also to researchers and students involved in studying power systems operations and control. .

  19. On Variable Reverse Power Flow-Part I: Active-Reactive Optimal Power Flow with Reactive Power of Wind Stations

    Directory of Open Access Journals (Sweden)

    Aouss Gabash

    2016-02-01

    Full Text Available It has recently been shown that using battery storage systems (BSSs to provide reactive power provision in a medium-voltage (MV active distribution network (ADN with embedded wind stations (WSs can lead to a huge amount of reverse power to an upstream transmission network (TN. However, unity power factors (PFs of WSs were assumed in those studies to analyze the potential of BSSs. Therefore, in this paper (Part-I, we aim to further explore the pure reactive power potential of WSs (i.e., without BSSs by investigating the issue of variable reverse power flow under different limits on PFs in an electricity market model. The main contributions of this work are summarized as follows: (1 Introducing the reactive power capability of WSs in the optimization model of the active-reactive optimal power flow (A-R-OPF and highlighting the benefits/impacts under different limits on PFs. (2 Investigating the impacts of different agreements for variable reverse power flow on the operation of an ADN under different demand scenarios. (3 Derivation of the function of reactive energy losses in the grid with an equivalent-π circuit and comparing its value with active energy losses. (4 Balancing the energy curtailment of wind generation, active-reactive energy losses in the grid and active-reactive energy import-export by a meter-based method. In Part-II, the potential of the developed model is studied through analyzing an electricity market model and a 41-bus network with different locations of WSs.

  20. Turbines, generators and associated plant incorporating modern power system practice

    CERN Document Server

    Littler, DJ

    1992-01-01

    The introduction of new 500 MW and 660 MW turbine generator plant in nuclear, coal- and oil-fired power stations has been partly responsible for the increase in generating capacity of the CEGB over the last 30 years. This volume provides a detailed account of experience gained in the development, design, manufacture, operation and testing of large turbine-generators in the last 20 years. With the advance in analytical and computational techniques, the application of this experience to future design and operation of large turbine-generator plant will be of great value to engineers in the indust

  1. Optimized Envelope Tracking Power Supply for Tetra2 Base Station RF Power Amplifier

    DEFF Research Database (Denmark)

    Høyerby, Mikkel Christian Wendelboe; Andersen, Michael Andreas E.

    2008-01-01

    An ultra-fast tracking power supply (UFTPS) for envelope tracking in a 50kHz 64-QAM Tetra2 base station power amplification system is demonstrated. A simple method for optimizing the step response of the PID+PD sliding-mode control system is presented and demonstrated, along with a PLL-based scheme...

  2. Development of a Cost-Effective Solar/Diesel Independent Power Plant for a Remote Station

    Directory of Open Access Journals (Sweden)

    Okeolu Samuel Omogoye

    2015-01-01

    Full Text Available The paper discusses the design, simulation, and optimization of a solar/diesel hybrid power supply system for a remote station. The design involves determination of the station total energy demand as well as obtaining the station solar radiation data. This information was used to size the components of the hybrid power supply system (HPSS and to determine its configuration. Specifically, an appropriate software package, HOMER, was used to determine the number of solar panels, deep-cycle batteries, and rating of the inverter that comprise the solar section of the HPSS. A suitable diesel generator was also selected for the HPSS after careful technical and cost analysis of those available in the market. The designed system was simulated using the HOMER software package and the simulation results were used to carry out the optimization of the system. The final design adequately meets the station energy requirement. Based on a life expectancy of twenty-five years, a cost-benefit analysis of the HPSS was carried out. This analysis shows that the HPSS has a lower cost as compared to a conventional diesel generator power supply, thus recommending the HPSS as a more cost-effective solution for this application.

  3. Wind Generators and Market Power

    DEFF Research Database (Denmark)

    Misir, Nihat

    oligopoly model, ownership of the wind generators by owners of fossil-fueled (peakload) generators decreases total peakload production and increases the market price. These effects increase with total wind generation and aggregate wind generator ownership. In the real options model, start up and shut down...... price thresholds are significantly higher when the monopolist at the peakload level owns both types of generators. Furthermore, when producing electricity with the peakload generator, the monopolist can avoid facing prices below marginal cost by owning a certain share of the wind generators....

  4. Radio-location of mobile stations in third generation networks

    Directory of Open Access Journals (Sweden)

    Milan Manojle Šunjevarić

    2013-06-01

    Full Text Available Mobile station localization in mobile networks started with simple methods (e.g. Cell-ID method which required only slight modifications of network infrastructures. Principally, it was about network localization by which a localization service became available to all types of mobile phones. Due to low precision, the initiated development of more sophisticated methods has not been finished yet. Among the advanced location-based methods are those based on the measurement of location parameters in the time domain. In this paper the general consideration of radio location methods in 3G (UMTS radio networks is presented. The use of time based measurement methods was analysed in detail. Due to the limited article length, the use of other locating methods in 3G networks (based on power measurements, on radio direction measurement, and on cells identification – Cell ID and global positioning system - GPS are not described. Introduction Mobile station localization within modern cellular networks increases the level of user security and opens wide opportunities for commercial operators who provide this service. The major obstacle for the implementation of this service, which also prevents its practical usage, is the modification of the existing network infrastructure. In general, depending on the infrastructure used, positioning methods can be divided into two groups: integrated and independent. Integrated methods are primarily created for communication networks. A possibility to locate users represents just an additional service within a radio network. Independent methods are totally detached from the communication network in which the user whose location is being determined is. Radio location methods Determining the location of a mobile radio station is performed by determining the intersection of two or more lines of position. These lines represent the position of the set of points at which the mobile station may be located. These lines can be: (a

  5. Uncertainty Sets For Wind Power Generation

    OpenAIRE

    Dvorkin, Yury; Lubin, Miles; Backhaus, Scott; Chertkov, Michael

    2015-01-01

    As penetration of wind power generation increases, system operators must account for its stochastic nature in a reliable and cost-efficient manner. These conflicting objectives can be traded-off by accounting for the variability and uncertainty of wind power generation. This letter presents a new methodology to estimate uncertainty sets for parameters of probability distributions that capture wind generation uncertainty and variability.

  6. Electronic power generators for ultrasonic frequencies

    Science.gov (United States)

    Ciovica, D.

    1974-01-01

    The design and construction of an ultrasonic frequency electronic power generator are discussed. The principle design elements of the generator are illustrated. The generator provides an inductive load with an output power of two kilowatts and a variable output frequency in the fifteen to thirty KiloHertz range. The method of conducting the tests and the results obtained with selected materials are analyzed.

  7. Probabilistic seismic hazard assessment for Point Lepreau Generating Station

    Energy Technology Data Exchange (ETDEWEB)

    Mullin, D. [New Brunswick Power Corp., Point Lepreau Generating Station, Lepreau, New Brunswick (Canada); Lavine, A. [AMEC Foster Wheeler Environment and Infrastructure Americas, Oakland, California (United States); Egan, J. [SAGE Engineers, Oakland, California (United States)

    2015-09-15

    A Probabilistic Seismic Hazard Assessment (PSHA) has been performed for the Point Lepreau Generating Station (PLGS). The objective is to provide characterization of the earthquake ground shaking that will be used to evaluate seismic safety. The assessment is based on the current state of knowledge of the informed scientific and engineering community regarding earthquake hazards in the site region, and includes two primary components-a seismic source model and a ground motion model. This paper provides the methodology and results of the PLGS PSHA. The implications of the updated hazard information for site safety are discussed in a separate paper. (author)

  8. Operating Experience at the Aagesta Nuclear Power Station

    Energy Technology Data Exchange (ETDEWEB)

    Sandstroem, S. (ed.)

    1966-09-15

    Sweden's first nuclear power reactor Agesta, achieved criticality on July 17, 1963. Full power (65 MW{sub t}) was attained on March 20, 1964. Aagesta is a heavy water cooled and moderated pressure vessel reactor used for production of electricity as well as for district heating. The design, assembly and construction etc, of the reactor was described in detail in a staff report by AB Atomenergi, 'The Aagesta Nuclear Power Station' edited by B McHugh, which was published in September, 1964. In the book experiences from the commissioning and the first operation of the reactor were reported as well as findings from the extensive reactor physics studies made during this period. The report now presented is written by members of the operating team at Aagesta since its start. It reflects in general the experiences up to the end of 1965. The Aagesta Log, however, covers the period up to the normal summer stop 1966. The reactor has hitherto produced 506,000 MWh power of which 48,700 MWh have been electric power. In July 1965 the responsibility for the reactor operation was taken over by the Swedish State Power Board from AB Atomenergi, which company had started the reactor and operated it until the summer break 1965.

  9. Power generation in the open market

    Energy Technology Data Exchange (ETDEWEB)

    Crossett, T. (National Society for Clean Air, Brighton (UK))

    1992-09-01

    The article describes power generation in the United Kingdom. The open market for electricity, in which generators compete to supply electricity to the National Grid Company, is described. Other aspects discussed are: types of power plant; engineering challenges associated with different types of power plant; combined heat and power (CHP) systems; fossil fuel emissions; fossil fuel reserves; energy efficiency; and environmental costs. 1 fig., 4 tabs.

  10. Thermoelectric power generator with intermediate loop

    Science.gov (United States)

    Bell, Lon E; Crane, Douglas Todd

    2013-05-21

    A thermoelectric power generator is disclosed for use to generate electrical power from heat, typically waste heat. An intermediate heat transfer loop forms a part of the system to permit added control and adjustability in the system. This allows the thermoelectric power generator to more effectively and efficiently generate power in the face of dynamically varying temperatures and heat flux conditions, such as where the heat source is the exhaust of an automobile, or any other heat source with dynamic temperature and heat flux conditions.

  11. Measuring Atmospheric Emissions of CH4 from Permafrost with Remote Low-Power Automated Stations

    Science.gov (United States)

    Burba, G. G.; Anderson, T.; Haapanala, S.; Mammarella, I.; McDermitt, D. K.; Oechel, W. C.; Peltola, O.; Rinne, J.; Schreiber, P.; Sturtevant, C. S.; Zulueta, R. C.

    2012-12-01

    number of permafrost ecosystems (Fig.1). Principles of operation, station characteristics, and method requirements are also discussed. Figure 1. Different types of automated remote low-power stations, indicated by stars, measure methane emission rates in cold regions using the eddy covariance technique. A satellite map of light intensity at night (NASA, 2006) is used as a proxy for power grid distribution, and is overlaid on a satellite map of methane concentration in the atmosphere (SCIAMACHY, 2005), showing the lack of proximity of mains power to methane generating areas of the Earth. The dotted white line is an approximate permafrost border.

  12. Geothermal power generation in United States

    Science.gov (United States)

    Braun, Gerald W.; McCluer, H. K.

    1993-03-01

    Geothermal energy is an indigenous environmentally benign heat source with the potential for 5000-10,000 GWe of power generation in the United States. Approximately 2535 MWe of installed capacity is currently operating in the U.S. with contracted power costs down to 4.6 cents/kWh. This paper summarizes: 1) types of geothermal resources; 2) power conversion systems used for geothermal power generation; 3) environmental aspects; 4) geothermal resource locations, potential, and current power plant development; 5) hurdles, bottlenecks, and risks of geothermal power production; 6) lessons learned; and 7) ongoing and future geothermal research programs.

  13. Directly driven generators for wind power applications

    Energy Technology Data Exchange (ETDEWEB)

    Lampola, P. [Helsinki Univ. of Technology, Espoo (Finland). Lab. of Electromechanics

    1995-12-31

    The article deals with an analysis of directly driven, low-speed wind generators. The generators studied were a permanent-magnet synchronous machine and an asynchronous machine. The machines were compared with a typical generator of a wind power plant. The electromagnetic optimization of the machines was done by the finite element method. The rated power of the generators was 500 kW and the rotational speed was 40 rpm. (author)

  14. Biofouling surveillance at a power station with seawater intake gates

    Energy Technology Data Exchange (ETDEWEB)

    Sasikumar, N.; Nair, K.V.K. [Indira Gandhi Centre for Atomic Research, Kalpakkam (India)

    1997-04-01

    Biofouling monitoring of the seawater intake gates of Madras` atomic power station (MAPS) in India was carried out for a period of two years. The settlement and growth rates, composition, and biomass of fouling between the intake filter gates and the test panels exposed in the coastal waters were compared and the results showed significant differences. The major foulant of the tunnel -green mussel, Perna viridis, and barnacle, Megabalanus tintinnabulum - though generally absent on test panels, was present on the intake gates. Relatively-high growth rates with heavy biomass were found at the intake gates as compared to the test panel. The study suggests that the intake gates can be used for a reliable fouling prediction in coastal power plants. (Author).

  15. High pressure axial flow fans for modern coal power stations

    Energy Technology Data Exchange (ETDEWEB)

    Cyrus, Vaclav [AHT Energetika s.r.o., Praha (Czech Republic); Koci, Petr [ZVVZ Milevsko a.s. (Czech Republic)

    2008-07-01

    Brown coal fired power stations, located in Northern Bohemia, have mostly older boiler blocks with an output of 110 and 200 MWe. Flue gases are cleaned by the desulphurization plants installed between 1993 and 1997. Usually, each boiler block has two air fans and one to three flue gas fans. Flue gas fans operate in severe conditions; fan blades should be resistant to the flue gases containing sulphur and acid drops with the operating temperature at 170 C to 190 C. Additionally, flue gas also often contains ash particles. Currently, some boiler blocks are gradually being refurbished. New blocks with an electrical power output of 600 to 700 MWe are at the design stage. Submitted paper shows our design study of one stage axial flow fan for the new blocks. Results from the new aerodynamic research of the axial flow stages were used in the fan design. (orig.)

  16. Power Quality Improvement of a Distributed Generation Power System

    Directory of Open Access Journals (Sweden)

    Panga Harish

    2016-06-01

    Full Text Available The aim of this work is to improve the power quality for Distributed Generation (DG with power storage system. Power quality is the combination of voltage quality and current quality. Power quality is the set of limits of electrical properties that allows electrical systems to function in their intended manner without significant loss of performance or life. The electrical power quality is more concerned issue. The main problems are stationery and transient distortions in the line voltage such as harmonics, flicker, swells, sags and voltage asymmetries. Distributed Generation (DG also called as site generation, dispersed generation, embedded generation, decentralized generation, decentralized energy or distributed energy, generates electricity from the many small energy sources. In recent years, micro electric power systems such as photovoltaic generation systems, wind generators and micro gas turbines, etc., have increased with the deregulation and liberalization of the power market. Under such circumstances the environment surrounding the electric power industry has become ever more complicated and provides high-quality power in a stable manner which becomes an important topic. Here DG is assumed to include Wind power Generation (WG and Fuel Cells (FC, etc. Advantages of this system are constant power supply, constant voltage magnitude, absence of harmonics insupply voltage, un-interrupted power supply. In this project the electric power qualities in two cases will be compared. Case I: With the storage battery when it is introduced. Case II: Without the storage battery. The storage battery executes the control that maintains the voltage in the power system. It will be found that the Electric power quality will be improved, when storage battery is introduced. The model system used in this Project work is composed of a Wind Turbine, an Induction Generator, Fuel Cells, An Inverter and a Storage Battery. A miniature Wind Power Generator is

  17. Analysis of the Use of Wind Energy to Supplement the Power Needs at McMurdo Station and Amundsen-Scott South Pole Station, Antarctica

    Energy Technology Data Exchange (ETDEWEB)

    Baring-Gould, I.; Robichaud, R.; McLain, K.

    2005-05-01

    This report summarizes an analysis of the inclusion of wind-driven power generation technology into the existing diesel power plants at two U.S. Antarctic research stations, McMurdo and Amundsen-Scott South Pole Station. Staff at the U.S. Department of Energy's National Renewable Energy Laboratory (NREL) conducted the analysis. Raytheon Polar Services, which currently holds the private sector support contract for the two research stations, was a major contributor to this report. To conduct the analysis, available data were obtained on the wind resources, power plant conditions, load, and component cost. Whenever possible, we validated the information. We then used NREL's Hybrid2 power system modeling software to analyze the potential and cost of using wind turbine generators at the two aforementioned facilities. Unfortunately, the power systems and energy allocations at McMurdo and South Pole Station are being redeveloped, so it is not possible to validate future fuel use. This report is an initial assessment of the potential use of wind energy and should be followed by further, more detailed analysis if this option is to be considered further.

  18. Flyash disposal problems at thermal power stations - an experimental study

    Energy Technology Data Exchange (ETDEWEB)

    Reddy, E.S.; Peter, E.C.N.; Sastri, K.R.; Kura, B. [JNTU College of Engineering, Hyderabad (India). Dept. of Civil Engineering

    1999-06-10

    Disposal of fly ash at coal-fired power stations is carried out in the form of ash slurry by mixing the ash with water. The ash slurry is stored in an ash pond. The water in the slurry is gradually drained out, through decanting wells, earthen embankments and over spillways, leaving the ash to deposit in the pond. The design of decanting wells presently being used in power stations, such as Vijayawada in India allows a considerable amount of flyash to flow out with water, leading to the contamination of soil and the water courses. Further, the failure of earthen bunds of ash ponds, which results in a major damage to the environment, is mainly due to ineffective functioning of filters in the bunds. This paper presents the details of an experimental investigation carried out to study the role of geotextiles in improving the performance of decanting wells and earthen bunds. Two series of experiments were carried out. In the first series two model decanting wells were tested with geotextile lining. In the second series, a number of model earthen bunds were tested with and without geotextiles. Economics of providing geotextiles in earthen bunds is studied. The results indicated that, the use of geotextiles is economical and effective in improving the performance of decanting wells and the earthen bunds of an ash pond. 15 refs., 10 figs., 6 tabs.

  19. Determination of steam wetness in the steam-generating equipment of nuclear power plants

    Science.gov (United States)

    Gorburov, V. I.; Gorburov, D. V.; Kuz'min, A. V.

    2012-05-01

    Calculation and experimental methods for determining steam wetness in horizontal steam generators for nuclear power stations equipped with VVER reactors, namely, the classic salt technique and calculations based on operating parameters are discussed considered and compared.

  20. A comprehensive approach to selecting the water chemistry of the secondary coolant circuit in the projects of nuclear power stations equipped with VVER-1200 reactors

    Science.gov (United States)

    Tyapkov, V. F.

    2011-05-01

    The paper presents the results obtained from studies on selecting the water chemistry of the secondary coolant circuit carried out for the project of a nuclear power station equipped with a new-generation VVER-1200 reactor on the basis of case calculations and an analysis of field experience gained at operating nuclear power stations.

  1. Microwave power engineering generation, transmission, rectification

    CERN Document Server

    Okress, Ernest C

    1968-01-01

    Microwave Power Engineering, Volume 1: Generation, Transmission, Rectification considers the components, systems, and applications and the prevailing limitations of the microwave power technology. This book contains four chapters and begins with an introduction to the basic concept and developments of microwave power technology. The second chapter deals with the development of the main classes of high-power microwave and optical frequency power generators, such as magnetrons, crossed-field amplifiers, klystrons, beam plasma amplifiers, crossed-field noise sources, triodes, lasers. The third

  2. Cycloidal tidal power generation - Phase 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    This report summarises the findings of a project investigating the economic and technical viability of a cycloidal tidal stream generator and developing a performance prediction model to assess the applicability of cycloidal turbines to power generation. The concept of cycloidal power generation is described along with the use of the model to examine the performance of six designs in the tidal flow off the west coast of Scotland. Details are given of the estimated power generated and cost reductions using optimised designs. Areas to be examined for design optimisation are listed.

  3. Concentrated solar power generation using solar receivers

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Bruce N.; Treece, William Dean; Brown, Dan; Bennhold, Florian; Hilgert, Christoph

    2017-08-08

    Inventive concentrated solar power systems using solar receivers, and related devices and methods, are generally described. Low pressure solar receivers are provided that function to convert solar radiation energy to thermal energy of a working fluid, e.g., a working fluid of a power generation or thermal storage system. In some embodiments, low pressure solar receivers are provided herein that are useful in conjunction with gas turbine based power generation systems.

  4. Optimal prediction intervals of wind power generation

    OpenAIRE

    Wan, Can; Wu, Zhao; Pinson, Pierre; Dong, Zhao Yang; Wong, Kit Po

    2014-01-01

    Accurate and reliable wind power forecasting is essential to power system operation. Given significant uncertainties involved in wind generation, probabilistic interval forecasting provides a unique solution to estimate and quantify the potential impacts and risks facing system operation with wind penetration beforehand. This paper proposes a novel hybrid intelligent algorithm approach to directly formulate optimal prediction intervals of wind power generation based on extreme learning machin...

  5. 75 FR 63766 - Digital Low Power Television, Television Translator, and Television Booster Stations and Digital...

    Science.gov (United States)

    2010-10-18

    ... COMMISSION 47 CFR Parts 73 and 74 Digital Low Power Television, Television Translator, and Television Booster Stations and Digital Class A Television Stations AGENCY: Federal Communications Commission. ACTION... that need to be resolved to complete the low power television station digital transition....

  6. Estimation of Power Production Potential from Natural Gas Pressure Reduction Stations in Pakistan Using ASPEN HYSYS

    Directory of Open Access Journals (Sweden)

    Imran Nazir Unar

    2015-07-01

    Full Text Available Pakistan is a gas rich but power poor country. It consumes approximately 1, 559 Billion cubic feet of natural gas annually. Gas is transported around the country in a system of pressurized transmission pipelines under a pressure range of 600-1000 psig exclusively operated by two state owned companies i.e. SNGPL (Sui Northern Gas Pipelines Limited and SSGCL (Sui Southern Gas Company Limited. The gas is distributed by reducing from the transmission pressure into distribution pressure up to maximum level of 150 psig at the city gate stations normally called SMS (Sales Metering Station. As a normal practice gas pressure reduction at those SMSs is accomplished in pressure regulators (PCVs or in throttle valves where isenthalpic expansion takes place without producing any energy. Pressure potential of natural gas is an untapped energy resource which is currently wasted by its throttling. This pressure reduction at SMS (pressure drop through SMS may also be achieved by expansion of natural gas in TE, which converts its pressure into the mechanical energy, which can be transmitted any loading device for example electric generator. The aim of present paper is to explore the expected power production potential of various Sales Metering Stations of SSGCL company in Pakistan. The model of sales metering station was developed in a standard flow sheeting software Aspen HYSYS®7.1 to calculate power and study other parameters when an expansion turbine is used instead of throttling valves. It was observed from the simulation results that a significant power (more than 140 KW can be produced at pressure reducing stations of SSGC network with gas flows more than 2.2 MMSCFD and pressure ration more than 1.3.

  7. SOARCA Peach Bottom Atomic Power Station Long-Term Station Blackout Uncertainty Analysis: Knowledge Advancement.

    Energy Technology Data Exchange (ETDEWEB)

    Gauntt, Randall O.; Mattie, Patrick D.; Bixler, Nathan E.; Ross, Kyle W.; Cardoni, Jeffrey N; Kalinich, Donald A.; Osborn, Douglas.; Sallaberry, Cedric Jean-Marie; Ghosh, S. Tina

    2014-02-01

    This paper describes the knowledge advancements from the uncertainty analysis for the State-of- the-Art Reactor Consequence Analyses (SOARCA) unmitigated long-term station blackout accident scenario at the Peach Bottom Atomic Power Station. This work assessed key MELCOR and MELCOR Accident Consequence Code System, Version 2 (MACCS2) modeling uncertainties in an integrated fashion to quantify the relative importance of each uncertain input on potential accident progression, radiological releases, and off-site consequences. This quantitative uncertainty analysis provides measures of the effects on consequences, of each of the selected uncertain parameters both individually and in interaction with other parameters. The results measure the model response (e.g., variance in the output) to uncertainty in the selected input. Investigation into the important uncertain parameters in turn yields insights into important phenomena for accident progression and off-site consequences. This uncertainty analysis confirmed the known importance of some parameters, such as failure rate of the Safety Relief Valve in accident progression modeling and the dry deposition velocity in off-site consequence modeling. The analysis also revealed some new insights, such as dependent effect of cesium chemical form for different accident progressions. (auth)

  8. Modern concepts of thermodynamic optimization in Mexican thermoelectric power stations; Conceptos modernos de optimacion termodinamica en centrales termoelectricas mexicanas

    Energy Technology Data Exchange (ETDEWEB)

    Cervantes de Gortari, J.; Vidal Santo, A.; Mendez Lavielle, F.; Bautista Godinez, O. [Facultad de Ingenieria, UNAM, Mexico, D.F. (Mexico)

    2002-03-01

    In this paper, a summary review of the current thermodynamic concepts to the maximum power generation and minimum entropy production are presented. The results of the analysis are considered in Mexican power stations using conventional cycles and are compared with other power stations around the world. [Spanish] En este trabajo se revisa el analisis de maxima generacion de potencia que implica la minimizacion de la produccion de entropia en centrales generadoras de potencia, de acuerdo con los lineamientos mas recientes publicados en la literatura. Los conceptos y resultados del analisis se aplican a varias centrales mexicanas y se comparan con otras centrales en el mundo.

  9. Electromechanical Peak Devices of Distributed Power Generation

    Directory of Open Access Journals (Sweden)

    S. V. Konstantinova

    2011-01-01

    Full Text Available The power world crises (1973, 1979 have demonstrated that mankind entered the expensive energy epoch. More and more attitude is given to power saving problem by including renewable power sources in energy balance of the countries. The paper analyzes a power system inBelarusand a typical chart of the active load is cited in the paper. Equalization of load chart is considered as one of measures directed on provision of higher operational efficiency of power system and power saving.  This purpose can be obtained while including electromechanical peak devices of the distributed generation in the energy balance.

  10. Management Innovations in Power Generation Groups

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    @@ Since the institutional reform of power industry in 2002,power sectors,in particularelectrity generation enterprises in China have been grently changed, not only in institutionand industrial pattern but also in operational environment.The year2006is a turning point of tense power supply lasting for three years and a half .The change of power supply situationin the 11th Five-Year Plan period and in-depth reform of power institutional systm haveplaced serious challenges in front of power genration groups.In this new historical era,powergeneration groups can keep undefeated only by carrying out actively mangement innovations.

  11. An Implanted, Stimulated Muscle Powered Piezoelectric Generator

    Science.gov (United States)

    Lewandowski, Beth; Gustafson, Kenneth; Kilgore, Kevin

    2007-01-01

    A totally implantable piezoelectric generator system able to harness power from electrically activated muscle could be used to augment the power systems of implanted medical devices, such as neural prostheses, by reducing the number of battery replacement surgeries or by allowing periods of untethered functionality. The features of our generator design are no moving parts and the use of a portion of the generated power for system operation and regulation. A software model of the system has been developed and simulations have been performed to predict the output power as the system parameters were varied within their constraints. Mechanical forces that mimic muscle forces have been experimentally applied to a piezoelectric generator to verify the accuracy of the simulations and to explore losses due to mechanical coupling. Depending on the selection of system parameters, software simulations predict that this generator concept can generate up to approximately 700 W of power, which is greater than the power necessary to drive the generator, conservatively estimated to be 50 W. These results suggest that this concept has the potential to be an implantable, self-replenishing power source and further investigation is underway.

  12. Microscale combustion and power generation

    CERN Document Server

    Cadou, Christopher

    2014-01-01

    Recent advances in microfabrication technologies have enabled the development of entirely new classes of small-scale devices with applications in fields ranging from biomedicine, to wireless communication and computing, to reconnaissance, and to augmentation of human function. In many cases, however, what these devices can actually accomplish is limited by the low energy density of their energy storage and conversion systems. This breakthrough book brings together in one place the information necessary to develop the high energy density combustion-based power sources that will enable many of

  13. Small geothermic heat and power station with power plants on organic fluid

    Energy Technology Data Exchange (ETDEWEB)

    Nowak, W.; Wos, M. [Szczecin Univ. of Tech. (Poland). Chair of Heat Engineering

    2006-07-01

    The results of the calculations of heat-flow heats and power stations were introduced in the work geothermic with one circulation, with two circulations and with three circulations. They are reinforced network water heated up in the geothermic heat exchanger to temperatures 100 C and stream. In this solution the temperature of water force to the geothermic hest exchanger changes and amount out suitably 39,35 C (one circulation), 49,83 C (two circulations), 58,91 C (three circulations). He results that the solution of heat and power station is the most profitable variant with three circulations from the analysis of the received results of calculations. He keeps the highest power of the circulation C.R. from three considered variants. (orig.)

  14. Computerized training program usage at the Fort Calhoun Nuclear Power Station

    Energy Technology Data Exchange (ETDEWEB)

    Ruzic, D.H.; Reed, W.H.; Lawton, R.K.; Fluehr, J.J.

    1987-01-01

    The increased US Nuclear Regulatory Commission and Institute of Nuclear Power Operations (INPO) interest in the nuclear power industry training programs resulted in the Omaha Public Power District staff at the Fort Calhoun Nuclear Power Station investigating the potential for computerizing their recently accredited training records, student training requirements, and the process of determining student certification status. Additional areas that were desirable were a computerized question data bank with random test generation, maintaining history of question usage, and tracking of the job task analysis process and course objectives. SCI Software's online personnel training information management system (OPTIM) was selected, subsequent to a bid evaluation, to provide these features while operating on the existing corporate IBM mainframe.

  15. Converters for Distributed Power Generation Systems

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Yang, Yongheng

    2015-01-01

    Power electronics technology has become the enabling technology for the integration of distributed power generation systems (DPGS) such as offshore wind turbine power systems and commercial photovoltaic power plants. Depending on the applications, a vast array of DPGS-based power converter...... presents an overview of the power converters for the DPGS, mainly based on wind turbine systems and photovoltaic systems, covering a wide range of applications. Moreover, the modulation schemes and interfacing power filters for the power converters are also exemplified. Finally, the general control...... topologies has been developed and more are coming into the market in order to achieve an efficient and reliable power conversion from the renewables. In addition, stringent demands from both the distribution system operators and the consumers have been imposed on the renewable-based DPGS. This article...

  16. Electrical Power Conversion of River and Tidal Power Generator

    Energy Technology Data Exchange (ETDEWEB)

    Muljadi, Eduard; Gevorgian, Vahan; Wright, Alan; Donegan, James; Marnagh, Cian; McEntee, Jarlath

    2016-11-21

    As renewable generation has become less expensive during recent decades, and it becomes more accepted by the global population, the focus on renewable generation has expanded to include new types with promising future applications, such as river and tidal generation. Although the utilization of power electronics and electric machines in industry is phenomenal, the emphasis on system design is different for various sectors of industry. In precision control, robotics, and weaponry, the design emphasis is on accuracy and reliability with less concern for the cost of the final product. In energy generation, the cost of energy is the prime concern; thus, capital expenditures (CAPEX) and operations and maintenance expenditures (OPEX) are the major design objectives. This paper describes the electrical power conversion aspects of river and tidal generation. Although modern power converter control is available to control the generation side, the design was chosen on the bases of minimizing the CAPEX and OPEX; thus, the architecture is simple and modular for ease of replacement and maintenance. The power conversion is simplified by considering a simple diode bridge and a DC-DC power converter to take advantage of abundant and low-cost photovoltaic inverters that have well-proven grid integration characteristics (i.e., the capability to produce energy with good power quality and control real power and voltage on the grid side).

  17. Power transmission cable development for the Space Station Freedom electrical power system

    Science.gov (United States)

    Schmitz, Gregory V.; Biess, John J.

    1989-01-01

    Power transmission cable is presently being evaluated under a NASA Lewis Research Center advanced development contract for application in the Space Station Freedom (SSF) electrical power system (EPS). Evaluation testing has been performed by TRW and NASA Lewis Research Center. The results of this development contract are presented. The primary cable design goals are to provide (1) a low characteristic inductance to minimize line voltage drop at 20 kHz, (2) electromagnetic compatibility control of the 20-kHz ac power current, (3) a physical configuration that minimizes ac resistance and (4) release of trapped air for corona-free operation.

  18. Development of micro power generators - A review

    Energy Technology Data Exchange (ETDEWEB)

    Chou, S.K.; Yang, W.M.; Chua, K.J.; Li, J. [Department of Mechanical Engineering, National University of Singapore, 9 Engineering Drive 1, Singapore 117576 (Singapore); Zhang, K.L. [Department of Manufacturing Engineering and Engineering Management, City University of Hong Kong, 83 Tat Chee Avenue (China)

    2011-01-15

    The demand for energy sources that are compact, lightweight and powerful has significantly increased in recent years. Traditional chemical batteries which are highly developed are unable to meet the demand for high energy intensity. This gap is expected to widen in the future as electronic devices need more power to support enhanced functionalities. Hydrocarbon fuels have energy densities much greater than the best batteries. Therefore, taking advantage of the high energy density of chemical fuels to generate power becomes an attractive technological alternative to batteries. To address the growing demand for smaller scale and higher energy density power sources, various combustion-based micro power generators are being developed around the world. This review paper provides an update on recent progresses and developments in micro-scale combustion and micro power generators. The paper, broadly divided into four main sections, begins with a review of various methods to enhance and stabilize the combustion at micro-scale, subsequently improving the efficiency. This is followed by a description of various micro-thermophotovoltaic power generators. The third section focuses on MEMS based solid propellant micro-propulsion system. Lastly, a brief review is made to other micro power generators. (author)

  19. Power Smoothing and MPPT for Grid-connected Wind Power Generation with Doubly Fed Induction Generator

    Science.gov (United States)

    Kai, Takaaki; Tanaka, Yuji; Kaneda, Hirotoshi; Kobayashi, Daichi; Tanaka, Akio

    Recently, doubly fed induction generator (DFIG) and synchronous generator are mostly applied for wind power generation, and variable speed control and power factor control are executed for high efficiently for wind energy capture and high quality for power system voltage. In variable speed control, a wind speed or a generator speed is used for maximum power point tracking. However, performances of a wind generation power fluctuation due to wind speed variation have not yet investigated for those controls. The authors discuss power smoothing by those controls for the DFIG inter-connected to 6.6kV distribution line. The performances are verified using power system simulation software PSCAD/EMTDC for actual wind speed data and are examined from an approximate equation of wind generation power fluctuation for wind speed variation.

  20. Performance Analyses of Renewable and Fuel Power Supply Systems for Different Base Station Sites

    Directory of Open Access Journals (Sweden)

    Josip Lorincz

    2014-11-01

    Full Text Available Base station sites (BSSs powered with renewable energy sources have gained the attention of cellular operators during the last few years. This is because such “green” BSSs impose significant reductions in the operational expenditures (OPEX of telecom operators due to the possibility of on-site renewable energy harvesting. In this paper, the green BSSs power supply system parameters detected through remote and centralized real time sensing are presented. An implemented sensing system based on a wireless sensor network enables reliable collection and post-processing analyses of many parameters, such as: total charging/discharging current of power supply system, battery voltage and temperature, wind speed, etc. As an example, yearly sensing results for three different BSS configurations powered by solar and/or wind energy are discussed in terms of renewable energy supply (RES system performance. In the case of powering those BSS with standalone systems based on a fuel generator, the fuel consumption models expressing interdependence among the generator load and fuel consumption are proposed. This has allowed energy-efficiency comparison of the fuel powered and RES systems, which is presented in terms of the OPEX and carbon dioxide (CO2 reductions. Additionally, approaches based on different BSS air-conditioning systems and the on/off regulation of a daily fuel generator activity are proposed and validated in terms of energy and capital expenditure (CAPEX savings.

  1. Reactive power management of power networks with wind generation

    CERN Document Server

    Amaris, Hortensia; Ortega, Carlos Alvarez

    2012-01-01

    As the energy sector shifts and changes to focus on renewable technologies, the optimization of wind power becomes a key practical issue. Reactive Power Management of Power Networks with Wind Generation brings into focus the development and application of advanced optimization techniques to the study, characterization, and assessment of voltage stability in power systems. Recent advances on reactive power management are reviewed with particular emphasis on the analysis and control of wind energy conversion systems and FACTS devices. Following an introduction, distinct chapters cover the 5 key

  2. Monitoring of Power Station Steels Using Electromagnetic Sensors

    OpenAIRE

    Karimian, Noushin

    2014-01-01

    With the world’s aging power generation network, especially in Europe and the United States, life-extension of steel plant components is increasingly a critical issue, as components are exposed to high temperatures and pressures during their lifetime, potentially resulting in carbide coarsening, making them prone to creep cavitation, possibly leading to component failure. Therefore, in order to evaluate the likelihood of component failure, non-destructive testing and evaluation procedures mus...

  3. Wind power, distrubted generation and transmission

    DEFF Research Database (Denmark)

    Østergaard, Poul Alberg

    Denmark has the World?s highest penetration of wind power in electricity generation with a share of 15.0% of total domestic demand in 2002 (DEA, 2004). This is unevenly distributed in the two electricity systems of Denmark giving a share as high as 20.7% in Western Denmark in 2003 up from 18...... relying on import or export for power balancing. The impacts on the transmission system are furthermore analysed demonstrating that new strategies for balancing power generation and power demand (power balancing strategies) also influence grid losses and the requirements of the transmission grid. If new.......3% in 2002 (Eltra, 2004). At the same time, Denmark has other forms of distributed generation e.g. extensive CHP plants for district heating or for covering industrial heat demands. This results in a relatively high fuel efficiency as well as a technically complex energy system. This article deliberates...

  4. 78 FR 45987 - Vogtle Electric Generating Station, Units 3 and 4; Southern Nuclear Operating Company; Change to...

    Science.gov (United States)

    2013-07-30

    ... COMMISSION Vogtle Electric Generating Station, Units 3 and 4; Southern Nuclear Operating Company; Change to... COLs were issued to Southern Nuclear Operating Company, Inc., and Georgia Power Company, Oglethorpe... Search.'' For problems with ADAMS, please contact the NRC's Public Document Room (PDR) reference staff...

  5. 78 FR 45989 - Vogtle Electric Generating Station, Units 3 and 4; Southern Nuclear Operating Company; Change to...

    Science.gov (United States)

    2013-07-30

    ... COMMISSION Vogtle Electric Generating Station, Units 3 and 4; Southern Nuclear Operating Company; Change to... COLs were issued to Southern Nuclear Operating Company, Inc., and Georgia Power Company, Oglethorpe..., select ``ADAMS Public Documents'' and then select ``Begin Web-based ADAMS Search.'' For problems...

  6. Carbon burnout of pulverised coal in power station furnaces

    Energy Technology Data Exchange (ETDEWEB)

    R.I. Backreedy; L.M. Fletcher; J.M. Jones; L. Ma; M. Pourkashanian; A. Williams; K. Johnson; D.J. Waldron; P. Stephenson [University of Leeds, Leeds (United Kingdom)

    2003-07-01

    The degree of carbon burnout in pulverised fuel fired power stations is important because it is linked with power plant efficiency and coal ash suitability for construction purposes. The use of computational methods to calculate carbon burnout in such systems has been aided by the increasing availability of fast computers and improvements in computational methodologies. Despite recent advances in fluid flow, coal devolatilisation and coal combustion models, the use of CFD methods for detailed design purposes or for the selection of commercial coals is still limited. In parallel, industrial engineering codes, which combine simplified thermal models with advanced coal combustion models, are still undergoing development since they provide economic advantages over detailed CFD analysis. Although the major coal combustion processes are well established, an understanding regarding the role of coal macerals and the influence of ash on the combustion process is still lacking. A successful coal model must be able to handle all the complexities of combustion, from the details of the burner geometry through to the formation of unburnt carbon as well as NOx. The development of such a model is described here.

  7. Integrated Power and Attitude Control Systems for Space Station

    Science.gov (United States)

    Oglevie, R. E.; Eisenhaure, D. B.

    1985-01-01

    Integrated Power and Attitude Control Systems (IPACS) studies performed over a decade ago established the feasibility of simultaneously storing electrical energy in wheels and utilizing the resulting momentum for spacecraft attitude control. It was shown that such a system possessed many advantages over other contemporary energy storage and attitude control systems in many applications. More recent technology advances in composite rotors, magnetic bearings, and power control electronics have triggered new optimism regarding the feasibility and merits of such a system. The paper presents the results of a recent study whose focus was to define an advanced IPACS and to evaluate its merits for the Space Station application. A system and component design concept is developed to establish the system performance capability. A system level trade study, including life-cycle costing, is performed to define the merits of the system relative to two other candidate systems. It is concluded that an advanced IPACS concept is not only feasible, but offers substantial savings in mass, and life-cycle cost.

  8. International Space Station power module thermal control system hydraulic performance

    Energy Technology Data Exchange (ETDEWEB)

    Goldberg, V. [Boeing North American, Inc., Canoga Park, CA (United States). Rocketdyne Div.

    1997-12-31

    The International Space Station (ISS) uses four photovoltaic power modules (PVMs) to provide electric power for the US On-Orbit Segment. The PVMs consist of photovoltaic arrays (PVAs), orbit replaceable units (ORUs), photovoltaic radiators (PVRs), and a thermal control system (TCS). The PVM TCS function is to maintain selected PVM components within their specified operating ranges. The TCS consists of the pump flow control subassembly (PFCS), piping system, including serpentine tubing for individual component heat exchangers, headers/manifolds, fluid disconnect couplings (FQDCs), and radiator (PVR). This paper describes the major design requirements for the TCS and the results of the system hydraulic performance predictions in regard to these requirements and system component sizing. The system performance assessments were conducted using the PVM TCS fluid network hydraulic model developed for predicting system/component pressure losses and flow distribution. Hardy-Cross method of iteration was used to model the fluid network configuration. Assessments of the system hydraulic performance were conducted based on an evaluation of uncertainties associated with the manufacturing and design tolerances. Based on results of the analysis, it was concluded that all design requirements regarding system performance could be met. The hydraulic performance range, enveloping possible system operating parameter variations was determined.

  9. Bike-powered electricity generator

    Directory of Open Access Journals (Sweden)

    ŞTEFAN MOCANU

    2015-02-01

    Full Text Available Finding new energy sources is an important challenge of our times. A lot of research focuses on identifying such sources that can also be exploited with relatively simple and efficient systems. These sources can be either new materials that can be used to generate energy, or solutions to scavenge already existing forms of energy. Part of the latter class of solutions, the system presented in this paper converts the energy consumed by many people in gyms (or even at home, during exercise into electric energy. This energy exists anyway, because people want to be healthier or to look better. Currently, this significant (in our opinion amount of energy is actually wasted and transformed into heat. Instead, in this study, a prototype scavenging system (dedicated to fitness/stationary bikes to collect and (reuse this energy is presented. Specifically, we depict the design of a low-budget system that uses existing, discrete components and is able to scavenge some of the energy spent by the biker. The experimental results show that the system is functional, but its efficiency is limited by (mechanical losses before the collection.

  10. DESIGNING AN OPPORTUNITY FUEL WITH BIOMASS AND TIRE-DERIVED FUEL FOR COFIRING AT WILLOW ISLAND GENERATING STATION AND COFIRING SAWDUST WITH COAL AT ALBRIGHT GENERATING STATION

    Energy Technology Data Exchange (ETDEWEB)

    K. Payette; D. Tillman

    2003-07-01

    During the period April 1, 2003--June 30, 2003, Allegheny Energy Supply Co., LLC (Allegheny) proceeded with demonstration operations at the Willow Island Generating Station and improvements to the Albright Generating Station cofiring systems. The demonstration operations at Willow Island were designed to document integration of biomass cofiring into commercial operations. The Albright improvements were designed to increase the resource base for the projects, and to address issues that came up during the first year of operations. This report summarizes the activities associated with the Designer Opportunity Fuel program, and demonstrations at Willow Island and Albright Generating Stations.

  11. DC-DC power converter research for Orbiter/Station power exchange

    Science.gov (United States)

    Ehsani, M.

    1993-01-01

    This project was to produce innovative DC-DC power converter concepts which are appropriate for the power exchange between the Orbiter and the Space Station Freedom (SSF). The new converters must interface three regulated power buses on SSF, which are at different voltages, with three fuel cell power buses on the Orbiter which can be at different voltages and should be tracked independently. Power exchange is to be bi-directional between the SSF and the Orbiter. The new converters must satisfy the above operational requirements with better weight, volume, efficiency, and reliability than is available from the present conventional technology. Two families of zero current DC-DC converters were developed and successfully adapted to this application. Most of the converters developed are new and are presented.

  12. Apparatus and method for thermal power generation

    Science.gov (United States)

    Cohen, Paul; Redding, Arnold H.

    1978-01-01

    An improved thermal power plant and method of power generation which minimizes thermal stress and chemical impurity buildup in the vaporizing component, particularly beneficial under loss of normal feed fluid and startup conditions. The invention is particularly applicable to a liquid metal fast breeder reactor plant.

  13. Leveled cost of the generation in a power station of combined cycle with integrated gas producer (CCGI); Costo nivelado de la generacion en una central de ciclo combinado con gasificador integrado (CCGI)

    Energy Technology Data Exchange (ETDEWEB)

    Hiriart Le Bert, Gerardo [Comision Federal de Electricidad (CFE), (Mexico); Beltran Mora, Hector [Facultad de Ingenieria, Universidad Nacional Autonoma de Mexico, Mexico, D.F. (Mexico)

    2004-06-15

    A brief description of a combined cycle power station that uses synthesis gas, better known as CCGI, is presented. The costs of the initial investment of several plants of this type, that have been described in literature, are analyzed and the predictions that different experts do on the costs that are expected in the near future are reviewed. Also the maintenance expenses that would be expected during the normal operation and the main maintenance are examined. The availability factors that reasonably must be considered based on the recent experiences are analyzed. Afterwards the sense which that the plant factor has in one of natural gas and one of synthesis, where generally are used as base plant. The costs of the different fuels that can be used in a CCGI are examined. Finally the leveled cost of the energy for both cases is calculated and the sensitivity of both to the cost of the respective fuels is examined. The result is presented in graphical form to show in a first attempt, the circumstances under which one or another technology could be preferable. It is made clear that the data used in this brief study are the best reasoned estimation and in no way they must be considered as definitive, in special in those of investment and maintenance of the CCGI where the operation history is still short. [Spanish] Se presenta una breve descripcion de una Central de Ciclo Combinado que utiliza Gas de Sintesis o mejor conocidas como CCGI. Se analizan los costos de la inversion inicial de varias plantas de este tipo que han sido descritas en la literatura y se resenan las predicciones que hacen diferentes expertos sobre los costos que se esperan para el futuro cercano. Tambien se examinan los gastos de mantenimiento que se esperarian durante la operacion normal y durante los mantenimientos mayores. Se analizan los factores de disponibilidad que razonablemente deben considerarse, basados en las experiencias recientes. Luego se discute el sentido que tiene el factor de

  14. Determination of Technological Electric Power Consumption for Its Transportation while Using Block-Stations

    Directory of Open Access Journals (Sweden)

    V. V. Pavlovets

    2010-01-01

    Full Text Available The paper proposes a method for calculation of the technological electric power consumption for its transportation in the elements of power network while using block-stations under conditions of differently-directed electric power transfer.The calculation of technological electric power consumption for its transportation can be applied while supplying several consumers with one element of power network simultaneously with block-station operation. 

  15. Entropy-generated power and its efficiency

    DEFF Research Database (Denmark)

    Golubeva, N.; Imparato, A.; Esposito, M.

    2013-01-01

    We propose a simple model for a motor that generates mechanical motion by exploiting an entropic force arising from the topology of the underlying phase space. We show that the generation of mechanical forces in our system is surprisingly robust to local changes in kinetic and topological paramet...... parameters. Furthermore, we find that the efficiency at maximum power may show discontinuities....

  16. Application of Power Electronics on Hydropower Generation

    Science.gov (United States)

    Hell, Johann

    2017-04-01

    The developments in power electronics are offering new opportunities in operation of hydro power generating units. The applied load in pump and turbine operation cannot be changed easily. By using of frequency converters, the speed of the units can be changed in a defined range, without losing much efficiency. An additional benefit of such kind of concept is the improved transient performance of the entire system. In the presented paper the advantage of speed variable power generating system equipped with frequency converters are shown.

  17. Space Station Freedom electric power system photovoltaic power module integrated launch package

    Science.gov (United States)

    Nathanson, Theodore H.; Clemens, Donald D.; Spatz, Raymond R.; Kirch, Luke A.

    1990-01-01

    The launch of the Space Station Freedom solar power module requires a weight efficient structure that will include large components within the limited load capacity of the Space Shuttle cargo bay. The design iterations to meet these requirements have evolved from a proposal concept featuring a separate cradle and integrated equipment assembly (IEA), to a package that interfaces directly with the Shuttle. Size, weight, and cost have been reduced as a result.

  18. Measurements and Modelling of Base Station Power Consumption under Real Traffic Loads

    Directory of Open Access Journals (Sweden)

    Goran Petrovic

    2012-03-01

    Full Text Available Base stations represent the main contributor to the energy consumption of a mobile cellular network. Since traffic load in mobile networks significantly varies during a working or weekend day, it is important to quantify the influence of these variations on the base station power consumption. Therefore, this paper investigates changes in the instantaneous power consumption of GSM (Global System for Mobile Communications and UMTS (Universal Mobile Telecommunications System base stations according to their respective traffic load. The real data in terms of the power consumption and traffic load have been obtained from continuous measurements performed on a fully operated base station site. Measurements show the existence of a direct relationship between base station traffic load and power consumption. According to this relationship, we develop a linear power consumption model for base stations of both technologies. This paper also gives an overview of the most important concepts which are being proposed to make cellular networks more energy-efficient.

  19. Optimal prediction intervals of wind power generation

    DEFF Research Database (Denmark)

    Wan, Can; Wu, Zhao; Pinson, Pierre

    2014-01-01

    Accurate and reliable wind power forecasting is essential to power system operation. Given significant uncertainties involved in wind generation, probabilistic interval forecasting provides a unique solution to estimate and quantify the potential impacts and risks facing system operation with wind...... penetration beforehand. This paper proposes a novel hybrid intelligent algorithm approach to directly formulate optimal prediction intervals of wind power generation based on extreme learning machine and particle swarm optimization. Prediction intervals with Associated confidence levels are generated through...... conducted. Comparing with benchmarks applied, experimental results demonstrate the high efficiency and reliability of the developed approach. It is therefore convinced that the proposed method provides a new generalized framework for probabilistic wind power forecasting with high reliability and flexibility...

  20. Counter rotating type hydroelectric unit suitable for tidal power station

    Energy Technology Data Exchange (ETDEWEB)

    Kanemoto, T [Faculty of Engineering, Kyushu Institute of Technology, Sensui 1-1, Tobata, Kitakyushu 804-8550 (Japan); Suzuki, T, E-mail: turbo@tobata.isc.kyutech.ac.j [Graduate School of Engineering, Kyushu Institute of Technology, Sensui 1-1, Tobata, Kitakyushu 804-8550 (Japan)

    2010-08-15

    The counter rotating type hydroelectric unit, which is composed of the axial flow type tandem runners and the peculiar generator with double rotational armatures,was proposed to utilize effectively the tidal power. In the unit, the front and the rear runners counter drive the inner and the outer armatures of the generator, respectively. Besides, the flow direction at the rear runner outlet must coincide with the flow direction at the front runner inlet, because the angular momentum through the rear runner must coincides with that through the front runner. That is, the flow runs in the axial direction at the rear runner outlet while the axial inflow at the front runner inlet. Such operations are suitable for working at the seashore with rising and falling tidal flows, and the unit may be able to take place of the traditional bulb type turbines. The tandem runners were operated at the on-cam conditions, in keeping the induced frequency constant. The output and the hydraulic efficiency are affected by the adjustment of the front and the blade setting angles. The both optimum angles giving the maximum output and/or efficiency were presented at the various discharges/heads. To promote more the tidal power generation by this type unit, the runners were also modified so as to be suitable for both rising and falling flows. The hydraulic performances are acceptable while the output is determined mainly by the trailing edge profiles of the runner blades.

  1. Vapor Online Monitor Model of Vapor Power Station Based on UML

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    We presents a vapor online monitor system model of vapor power station developed by visual tool rational rose2000. Use cases such as on line instrument (onlineinstr), control, query, report, real database (realdb) and alarm are generated according to the system requirements. Use case view and class view of the system are formed at the same time. As for all the UML models of the system, this paper focuses the discussion on the class view, the component diagram of the control class and the sequence diagram of the query class. Corresponding C++ codes are produced and finally transferred into the spot running software.

  2. The characteristic analysis of the solar energy photovoltaic power generation system

    Science.gov (United States)

    Liu, B.; Li, K.; Niu, D. D.; Jin, Y. A.; Liu, Y.

    2017-01-01

    Solar energy is an inexhaustible, clean, renewable energy source. Photovoltaic cells are a key component in solar power generation, so thorough research on output characteristics is of far-reaching importance. In this paper, an illumination model and a photovoltaic power station output power model were established, and simulation analysis was conducted using Matlab and other software. The analysis evaluated the condition of solar energy resources in the Baicheng region in the western part of Jilin province, China. The characteristic curve of the power output from a photovoltaic power station was obtained by simulation calculation. It was shown that the monthly average output power of the photovoltaic power station is affected by seasonal changes; the output power is higher in summer and autumn, and lower in spring and winter.

  3. 75 FR 8153 - Nebraska Public Power District; Cooper Nuclear Station Environmental Assessment and Finding of No...

    Science.gov (United States)

    2010-02-23

    ... COMMISSION Nebraska Public Power District; Cooper Nuclear Station Environmental Assessment and Finding of No... District (NPPD, the licensee), for operation of the Cooper Nuclear Station (CNS), located in Nemaha County... Statement for the Cooper Nuclear Station dated February 1973. Agencies and Persons Consulted In...

  4. Flyash disposal problems at thermal power stations - an experimental study

    Energy Technology Data Exchange (ETDEWEB)

    Reddy, E.S.; Peter, E.C. Nirmala; Sastri, K. Rama [JNTU Coll. of Engineering, Dept. of Civil Engineering, Hyderabad (India); Kura, Bhaskar [New Orleans Univ., Dept. of Civil and Environmental Engineering, New Orleans, LA (United States)

    1999-07-01

    Disposal of flyash at thermal power stations is carried out in the form of ash slurry by mixing the ash with water. The ash slurry is stored in an ash pond. The water in the slurry is gradually drained out, through decanting wells, earthen embankments and over spillways, leaving the ash to deposit in the pond. It is observed that, the design of decanting wells presently being used allows a considerable amount of flyash to flow out with water, leading to the contamination of soil and the water courses. Further, it is observed that, the failure of earthen bunds of ash ponds, which results in a major damage to the environment, is mainly due to ineffective functioning of filters in the bunds. This paper presents the details of an experimental investigation carried out to study the role of geotextiles in improving the performance of decanting wells and earthen bunds. Two series of experiments were carried out. In the first series two model decanting wells were tested with geotextile lining. In the second series, a number of model earthen bunds were tested with and without geotextiles. Economics of providing geotextiles in earthen bunds is studied. The results indicated that, the use of geotextiles is economical and effective improving the performance of decanting wells and the earthen bunds of an ash pond. (Author)

  5. The Fukushima Nuclear Power Station incident and marine pollution.

    Science.gov (United States)

    Chang, Yen-Chiang; Zhao, Yue

    2012-05-01

    Based on the facts relating to the radioactive wastewater discharged by the Fukushima Nuclear Power Station in Japan, this paper intends to explore the international legal obligations for Japan from three perspectives, namely, the immediate notification, the prevention of transboundary harm and the prevention of dumping. Furthermore, this article defines and compares two types of international legal liabilities, the traditional state responsibility and the responsibility for transboundary harm. Through comparison, the international legal liability of Japan is discussed. After detailed analysis, the conclusion is that Japan should be responsible for the obligation of immediate notification and since Japan unilaterally discharge the wastes without prior specific permits of other contracting countries, it should also be responsible for the violation of prevention of dumping. Since so far, no material injury has emerged and there would appear to be no culpability as regards the prevention of transboundary harm. Finally, this paper stresses the necessity to develop a worldwide agreement concerning the liability for transboundary harm and to establish an institutional framework for the enforcement of a state's obligations, and also the great significance of international cooperation between nations and organisations in relation to marine environmental protection. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. Insulating brick from fly ash of thermal power stations

    Energy Technology Data Exchange (ETDEWEB)

    Mukherjee, S.N.; Majumdar, A.; Majumdar, S.K.

    1986-04-01

    Disposal of fly ash, a major byproduct of thermal power stations burning high ash pulverized fuel, has posed a serious problem of storage space required on one hand and the cost involved on the other. Fly ash possesses pozzolanic property. R and D work on utilization of fly ash in the form of sand-lime brick or cellular concrete has been already done. Other avenues of utilization are cement and concrete industry. All these are based on pozzolanic property of fly ash which decreases with the increase of unburnt carbon content in the same. The overall present consumption of fly ash is barely 5-7 per cent of the total production. A process has been developed to utilize fly ash with comparatively higher amount of carbonaceous matter in particular, to make insulating/semi-insulating bricks of standard size through use of other normal ingredients like clay (a plastic material), sulphite lye, molasses, etc. as binder along with some propertion of saw dust. The bricks made so far have been tested for their normal properties and these conform to a product of semi-insulating type. 21 refs., 2 tabs.

  7. Secondary electrical design of station service power supply system for Lunzua Power Station in Zambia%赞比亚Lunzua水电站厂用电系统二次设计

    Institute of Scientific and Technical Information of China (English)

    袁艳艳; 黄卫平

    2015-01-01

    介绍了赞比亚Lunzua水电站厂用电系统二次设计思路,针对国外工程的特殊要求,将建筑电气常用的自动转换开关的自动化功能应用于水电站厂用电的自动化设计中,并研究了一套自动转换开关和柴油机自动投退相配合的厂用电自动化方案,实现了母线电源的自动切换和恢复,柴油发电机的自动启动、投入和停止。工程投运后,运行正常。%An introduction was made on the secondary electrical design ideas of station service power supply system of Lunzua Power Station in Zambia. In view of the special requirements of overseas projects, automatic transfer switch frequently used in architectural electric system was adopted in the station service power supply system of power station. Cooperation between automatic transfer switch and diesel generator under automatic on/off control permits automatic transfer and recovery of bus power, automatic start, operating or shutdown of diesel generator.The project has been operating normally since it was put into operation.

  8. Optimization and Feasibility Analysis of Satellite Earth Station Power System Using Homer

    Directory of Open Access Journals (Sweden)

    Hassen T. Dorrah

    2012-06-01

    Full Text Available Satellite earth stations which located in remote areas are one of many applications powered by the renewable energy sources. Ground system consists of ground station and control centers working together to support the spacecraft and the data user. Earth station consists of major subsystems, transmitter, receiver, antenna, tracking equipment, terrestrial interface equipment and power supply. Power subsystem is an important part that required for supplying the earth station with electrical power to continue communicating with its remote sensing satellite. This paper deals with simulation and optimal sizing of earth station power system using HOMER software. A combination of two energy sources (solar, and wind to provide a continuous electric power production is used to determine the optimum system operation. Three system configurations are compared with respect to the total net present cost (NPC and levelized cost of energy (COE. Also, economical study will be analyzed for energy demand and sensitivity analysis will be performed.

  9. Optimization and Feasibility Analysis of Satellite Earth Station Power System Using Homer

    Directory of Open Access Journals (Sweden)

    Hassen T. Dorrah

    2012-06-01

    Full Text Available Satellite earth stations which located in remote areas are one of many applications powered by the renewable energy sources. Ground system consists of ground station and control centers working together to support the spacecraft and the data user. Earth station consists of major subsystems, transmitter, receiver, antenna, tracking equipment, terrestrial interface equipment and power supply. Power subsystem is an important part that required for supplying the earth station with electrical power to continue communicating with its remote sensing satellite. This paper deals with simulation and optimal sizing of earth station power system using HOMER software. A combination of two energy sources (solar, and wind to provide a continuous electric power production is used to determine the optimum system operation. Three system configurations are compared with respect to the total net present cost (NPC and levelized cost of energy (COE. Also, economical study will be analyzed for energy demand and sensitivity analysis will be performed.

  10. Measurement of the Magnetic Properties of P9 and T22 Steel Taken from Service in Power Station

    OpenAIRE

    Wilson, JWa; Karimian, N a; Liu, J. B.; Yin, W a; Davis, CLb; Peyton, AJa

    2014-01-01

    With the UK's aging power generation network, life-extension of steel plant components is a critical issue. However, in order to evaluate the likelihood of component failure, techniques must be developed to properly assess the level of degradation in power station steels. Electromagnetic inspection has the potential to quantify the level of degradation through in-situ measurements at elevated temperatures. This paper reports the results of tests carried out on thermally treated P9 and T22 ste...

  11. Analysis of Linear MHD Power Generators

    Energy Technology Data Exchange (ETDEWEB)

    Witalis, E.A.

    1965-02-15

    The finite electrode size effects on the performance of an infinitely long MHD power generation duct are calculated by means of conformal mapping. The general conformal transformation is deduced and applied in a graphic way. The analysis includes variations in the segmentation degree, the Hall parameter of the gas and the electrode/insulator length ratio as well as the influence of the external circuitry and loading. A general criterion for a minimum of the generator internal resistance is given. The same criterion gives the conditions for the occurrence of internal current leakage between adjacent electrodes. It is also shown that the highest power output at a prescribed efficiency is always obtained when the current is made to flow between exactly opposed electrodes. Curves are presented showing the power-efficiency relations and other generator properties as depending on the segmentation degree and the Hall parameter in the cases of axial and transverse power extraction. The implications of limiting the current to flow between a finite number of identical electrodes are introduced and combined with the condition for current flow between opposed electrodes. The characteristics of generators with one or a few external loads can then be determined completely and examples are given in a table. It is shown that the performance of such generators must not necessarily be inferior to that of segmented generators with many independent loads. However, the problems of channel end losses and off-design loading have not been taken into consideration.

  12. Novel Radio on Fiber Access Eliminating External Electric Power Supply at Base Station

    Institute of Scientific and Technical Information of China (English)

    Tetsuya; Miki; Katsuyasu; Kawano; Nobuo; Nakajima; Naoto; Kishi; Masaru; Miyamoto; Tetsu; Aoki

    2003-01-01

    A novel Radio On Fiber(ROF) access is proposed and demonstrated which enables the pico-cell Base Station (BS) for high-speed wireless communications to eliminate external electric power supply facilities. We demonstrated 2.4-GHz band radio signal transmission through the BS without external electric power supply. The electrical power used for BS circuit is feeded by optical power over optical fiber from central station.

  13. Thermoelectric fabrics: toward power generating clothing.

    Science.gov (United States)

    Du, Yong; Cai, Kefeng; Chen, Song; Wang, Hongxia; Shen, Shirley Z; Donelson, Richard; Lin, Tong

    2015-03-23

    Herein, we demonstrate that a flexible, air-permeable, thermoelectric (TE) power generator can be prepared by applying a TE polymer (e.g. poly(3,4-ethylenedioxythiophene):poly(4-styrenesulfonate)) coated commercial fabric and subsequently by linking the coated strips with a conductive connection (e.g. using fine metal wires). The poly(3,4-ethylenedioxythiophene):poly(4-styrenesulfonate) coated fabric shows very stable TE properties from 300 K to 390 K. The fabric device can generate a TE voltage output (V) of 4.3 mV at a temperature difference (ΔT) of 75.2 K. The potential for using fabric TE devices to harvest body temperature energy has been discussed. Fabric-based TE devices may be useful for the development of new power generating clothing and self-powered wearable electronics.

  14. Piezoelectric devices for generating low power

    Science.gov (United States)

    Chilibon, Irinela

    2016-12-01

    This paper reviews concepts and applications in low-power electronics and energy harvesting technologies. Various piezoelectric materials and devices for small power generators useful in renewable electricity are presented. The vibrating piezoelectric device differs from the typical electrical power source in that it has capacitive rather than inductive source impedance, and may be driven by mechanical vibrations of varying amplitude. In general, vibration energy could be converted into electrical energy using one of three techniques: electrostatic charge, magnetic fields and piezoelectric. A low power piezoelectric generator, having a PZT element was realised in order to supply small electronic elements, such as optoelectronic small devices, LEDs, electronic watches, small sensors, interferometry with lasers or Micro-electro-mechanical System (MEMS) array with multi-cantilevers.

  15. Water pumps generate power efficiently; Wasserpumpen erzeugen wirtschaftlich Strom

    Energy Technology Data Exchange (ETDEWEB)

    Orchard, Bryan [KSB Aktiengesellschaft, Frankenthal (Germany)

    2010-09-15

    The water supply utility of Baden-Wuerttemberg and Bavaria (Zweckverband Landeswasserversorgung - ZV-LW) intended to construct another power generation stage in the Geislingen station. A longitudinally divided, single-stage spiral casing pump with a capacity of 600 kW was used as turbine; the investment cost and installation cost was only one fourth of the cost of a Francis turbine. Further, it is an advantage that the pump can also be used conventionally, i.e. in pump operation, to support drinking water transport. (orig.)

  16. 76 FR 11680 - Digital Low Power Television, Television Translator, and Television Booster Stations and Digital...

    Science.gov (United States)

    2011-03-03

    ... COMMISSION 47 CFR Parts 73 and 74 Digital Low Power Television, Television Translator, and Television Booster Stations and Digital Class A Television Stations AGENCY: Federal Communications Commission. ACTION: Final... 73 and 74 of the Commission's Rules to Establish Rules for Digital Low Power, Television...

  17. Construction of a nuclear power station in one's locality: attitudes and salience

    NARCIS (Netherlands)

    van der Pligt, J.; Eiser, J.R.; Spears, R.

    1986-01-01

    Examined the attitudes toward the building of a nuclear power station in one's locality by surveying 290 residents (mean age 47.5 yrs) of 3 small rural communities that were listed as possible locations for a new nuclear power station. Results show that a large majority of Ss opposed the building of

  18. 76 FR 72849 - Digital Low Power Television, Television Translator, and Television Booster Stations and To Amend...

    Science.gov (United States)

    2011-11-28

    ... COMMISSION 47 CFR Parts 73 and 74 Digital Low Power Television, Television Translator, and Television Booster... Rules to Establish Rules for Digital Low Power Television, Television Translator, and Television Booster Stations and to Amend Rules for Digital Class A Television Stations, MB Docket No. 03-185; FCC 11-110,...

  19. 78 FR 66385 - Omaha Public Power District Fort Calhoun Station, Unit 1; Exemption

    Science.gov (United States)

    2013-11-05

    ... From the Federal Register Online via the Government Publishing Office NUCLEAR REGULATORY COMMISSION Omaha Public Power District Fort Calhoun Station, Unit 1; Exemption 1.0 Background Omaha Public Power District (OPPD, the licensee) is the holder of Renewed Facility Operating License No. DPR-40, which authorizes operation of Fort Calhoun Station...

  20. 78 FR 37592 - Omaha Public Power District, Fort Calhoun Station, Unit 1; Exemption

    Science.gov (United States)

    2013-06-21

    ... From the Federal Register Online via the Government Publishing Office NUCLEAR REGULATORY COMMISSION Omaha Public Power District, Fort Calhoun Station, Unit 1; Exemption 1.0 Background Omaha Public Power District (OPPD, the licensee) is the holder of Facility Operating License, which authorizes operation of Fort Calhoun Station (FCS), Unit 1....

  1. Using plasma-fuel systems at Eurasian coal-fired thermal power stations

    Science.gov (United States)

    Karpenko, E. I.; Karpenko, Yu. E.; Messerle, V. E.; Ustimenko, A. B.

    2009-06-01

    The development of plasma technology for igniting solid fuels at coal-fired thermal power stations in Russia, Kazakhstan, China, and other Eurasian countries is briefly reviewed. Basic layouts and technical and economic characteristics of plasma-fuel systems installed in different coal-fired boiles are considered together with some results from using these systems at coal-fired thermal power stations.

  2. Using plasma-fuel systems at Eurasian coal-fired thermal power stations

    Energy Technology Data Exchange (ETDEWEB)

    E.I. Karpenko; Y.E. Karpenko; V.E. Messerle; A.B. Ustimenko [RAO Unified Energy Systems of Russia, Gusinoozersk (Russian Federation). Russia Sectional Center for Plasma-Power Technologies

    2009-07-01

    The development of plasma technology for igniting solid fuels at coal-fired thermal power stations in Russia, Kazakhstan, China, and other Eurasian countries is briefly reviewed. Basic layouts and technical and economic characteristics of plasma-fuel systems installed in different coal-fired boiles are considered together with some results from using these systems at coal-fired thermal power stations.

  3. Local opposition to the construction of a nuclear power station: differential salience of impacts

    NARCIS (Netherlands)

    Eiser, J.R.; van der Pligt, J.; Spears, R.

    1988-01-01

    Surveyed attitudes among 290 residents of 3 villages in southwest England toward proposals to build a nuclear power station nearby. Ss were grouped according to being neutral or in favor of a new power station either locally or elsewhere (Group PN), against one locally but neutral or pro elsewhere (

  4. International lunar observatory / power station: from Hawaii to the Moon

    Science.gov (United States)

    Durst, S.

    Astronomy's great advantages from the Moon are well known - stable surface, diffuse atmosphere, long cool nights (14 days), low gravity, far side radio frequency silence. A large variety of astronomical instruments and observations are possible - radio, optical and infrared telescopes and interferometers; interferometry for ultra- violet to sub -millimeter wavelengths and for very long baselines, including Earth- Moon VLBI; X-ray, gamma-ray, cosmic ray and neutrino detection; very low frequency radio observation; and more. Unparalleled advantages of lunar observatories for SETI, as well as for local surveillance, Earth observation, and detection of Earth approaching objects add significant utility to lunar astronomy's superlatives. At least nine major conferences in the USA since 1984 and many elsewhere, as well as ILEWG, IAF, IAA, LEDA and other organizations' astronomy-from-the-Moon research indicate a lunar observatory / power station, robotic at first, will be one of the first mission elements for a permanent lunar base. An international lunar observatory will be a transcending enterprise, highly principled, indispensable, soundly and broadly based, and far- seeing. Via Astra - From Hawaii to the Moon: The astronomy and scie nce communities, national space agencies and aerospace consortia, commercial travel and tourist enterprises and those aspiring to advance humanity's best qualities, such as Aloha, will recognize Hawaii in the 21st century as a new major support area and pan- Pacific port of embarkation to space, the Moon and beyond. Astronomical conditions and facilities on Hawaii's Mauna Kea provide experience for construction and operation of observatories on the Moon. Remote and centrally isolated, with diffuse atmosphere, sub-zero temperature and limited working mobility, the Mauna Kea complex atop the 4,206 meter summit of the largest mountain on the planet hosts the greatest collection of large astronomical telescopes on Earth. Lunar, extraterrestrial

  5. Conditional prediction intervals of wind power generation

    OpenAIRE

    Pinson, Pierre; Kariniotakis, Georges

    2010-01-01

    A generic method for the providing of prediction intervals of wind power generation is described. Prediction intervals complement the more common wind power point forecasts, by giving a range of potential outcomes for a given probability, their so-called nominal coverage rate. Ideally they inform of the situation-specific uncertainty of point forecasts. In order to avoid a restrictive assumption on the shape of forecast error distributions, focus is given to an empirical and nonparametric app...

  6. Transmission and Power Generation Investment under Uncertainty

    OpenAIRE

    Midttun, Nora Sunde; Sletten, Jannicke Soløy

    2015-01-01

    Regulated transmission system operators, (TSOs), need to anticipate generation capacity additions and accommodate future growth when building transmission lines. Given the last decades' deregulation of the European power sectors, EU policymakers are facing the challenge of achieving goals to mitigate climate change since they have relinquished control of the power sector. This challenge has contributed to an increased need for understanding how market participants will respond to TSOs' invest...

  7. On reliability optimization for power generation systems

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    The reliability level of a power generation system is an important problem which is concerned by both electricity producers and electricity consumers. Why? It is known that the high reliability level may result in additional utility cost, and the low reliability level may result in additional consumer's cost, so the optimum reliability level should be determined such that the total cost can reach its minimum. Four optimization models for power generation system reliability are constructed, and the proven efficient solutions for these models are also given.

  8. Autonomous Underwater Vehicle Thermoelectric Power Generation

    Science.gov (United States)

    Buckle, J. R.; Knox, A.; Siviter, J.; Montecucco, A.

    2013-07-01

    Autonomous underwater vehicles (AUVs) are a vital part of the oceanographer's toolbox, allowing long-term measurements across a range of ocean depths of a number of ocean properties such as salinity, fluorescence, and temperature profile. Buoyancy-based gliding, rather than direct propulsion, dramatically reduces AUV power consumption and allows long-duration missions on the order of months rather than hours or days, allowing large distances to be analyzed or many successive analyses of a certain area without the need for retrieval. Recent versions of these gliders have seen the buoyancy variation system change from electrically powered to thermally powered using phase-change materials, however a significant battery pack is still required to power communications and sensors, with power consumption in the region of 250 mW. The authors propose a novel application of a thermoelectric generation system, utilizing the depth-related variation in oceanic temperature. A thermal energy store provides a temperature differential across which a thermoelectric device can generate from repeated dives, with the primary purpose of extending mission range. The system is modeled in Simulink to analyze the effect of variation in design parameters. The system proves capable of generating all required power for a modern AUV.

  9. Wind power generation and dispatch in competitive power markets

    Science.gov (United States)

    Abreu, Lisias

    Wind energy is currently the fastest growing type of renewable energy. The main motivation is led by more strict emission constraints and higher fuel prices. In addition, recent developments in wind turbine technology and financial incentives have made wind energy technically and economically viable almost anywhere. In restructured power systems, reliable and economical operation of power systems are the two main objectives for the ISO. The ability to control the output of wind turbines is limited and the capacity of a wind farm changes according to wind speeds. Since this type of generation has no production costs, all production is taken by the system. Although, insufficient operational planning of power systems considering wind generation could result in higher system operation costs and off-peak transmission congestions. In addition, a GENCO can participate in short-term power markets in restructured power systems. The goal of a GENCO is to sell energy in such a way that would maximize its profitability. However, due to market price fluctuations and wind forecasting errors, it is essential for the wind GENCO to keep its financial risk at an acceptable level when constituting market bidding strategies. This dissertation discusses assumptions, functions, and methodologies that optimize short-term operations of power systems considering wind energy, and that optimize bidding strategies for wind producers in short-term markets. This dissertation also discusses uncertainties associated with electricity market environment and wind power forecasting that can expose market participants to a significant risk level when managing the tradeoff between profitability and risk.

  10. 闭环调节在解决一洞双机机组功率波动中的应用--以雅砻江锦东电站引水发电系统为例%Application of closed-loop control in solving power fluctuations of two units-one surge chamber:a case of water diversion and power generation system of Jindong Hydropower Station on Yalong River

    Institute of Scientific and Technical Information of China (English)

    陈鹏; 蒲瑜; 成建军

    2014-01-01

    The water diversion and power generation system of Jindong Hydropower Station, with large capacity, high head and"two units-one surge chamber", is described, especially the importance of closed-up control of hydro-generators power is fo-cused on. The main disadvantages of closed-loop control mode of the power are analyzed by taking account of the power regula-tion mode of governor system and monitoring system. The analysis involves the units operation condition and surge chamber fluc-tuation in the case of load shutdown of single hydro generator as well as units operation cases analysis under two modes of closed-loop and open-loop control. Furthermore, the improved measures are put forward in view of the main disadvantages of closed-loop control of the hydro-generators power of Jindong Hydropower Station.%介绍了锦东电站大容量、高水头、“一洞双机”引水发电系统,强调了锦东水轮发电机组功率闭环调节的重要性;结合锦东电站调速器、监控系统功率调节模式,分析了锦东机组功率闭环调节模式存在的主要不足。分析内容涉及:水力单元单机甩负荷后甩负荷机组运行工况与调压室浪涌波动分析;在闭环调节和开环调节两种模式下运行机组工况分析,以及针对锦东机组功率闭环调节模式存在的主要不足所提出的改进措施和建议等。可为其他类似机组功率闭环调节模式的设计及改进提供参考。

  11. Spillway gate rehabilitation and intake bulkhead design for Mactaquac generating station

    Energy Technology Data Exchange (ETDEWEB)

    Codrington, J.B.; Curtis, D.D. [Hatch Energy, Niagara Falls, ON (Canada); May, T.H. [NB Power Generation Corp., Mactaquac Generating Station, Keswick Ridge, NB (Canada)

    2007-07-01

    The Mactaquac generating station is located on the Saint John River in New Brunswick, upstream of Fredericton and is owned and operated by New Brunswick Power Generation Corporation. The station was constructed in stages between 1964 and 1980 and is the second largest hydroelectric generating facility in the Atlantic.The concrete of the structures is affected by an alkali-aggregate reaction (AAR) that causes the concrete to expand if unrestrained, or to develop large compressive forces, if restrained. In order to mitigate the effects of concrete expansion on the structures and equipment, several innovative remedial measures have been undertaken since 1985. This paper discussed a major gate rehabilitation project that began in 2001. The paper first identified the AAR effects on the spillway and on the intake gates. Next, the status of the spillway program and the refurbishment of the gates was discussed. The paper also identified the successes of the spillway program as well as the problems encountered. Last, the status of the intake program and findings from the program and future plans were presented. It was concluded that the program has provided opportunities to install features such as better handrails and improved access which are more in line with modern safe working requirements. The program has also identified a potential failure mode which will be prevented by the planned crack repairs. 2 refs., 15 figs.

  12. Technological upgrade of static system excitation of a hydraulic generator of 700 Mwats of the Hydroelectric Power Station Guri; Actualizacion tecnologica del sistema de excitacion estatico de un generador hidraulico de 700 MVA de la Central Hidroelectrica de Guri

    Energy Technology Data Exchange (ETDEWEB)

    Contreras, Romy; Guevara, Olivia [C.V.G. Electrificacion del Caroni, C.A. (EDELCA) (Venezuela)

    2004-07-01

    The Generating Units of 700 Mwatts of the Guri Plant from EDELCA are equipped with static excitation systems of analogue technology that using the closure and field's opening switch as a mechanism for the respective processes of excitation and generator dropout. This operational pattern, although functional, has been discontinuing by existing producers because of the inconvenience involved in the management of energy stored in field generator during the dropout. Alternatively, the manufacturers employ a technique of dropout without opening the switch field, based on return to the excitation transformer the energy contained in the field generator. This paper summarizes the EDELCA initiative to upgrade technologically their Generating Units, converting the excitement and dropout switch without opening the field. The project started with a phase of preliminary tests that showed the feasibility of the change and ended with the final implementation of the new scheme in a first unit (Generator n. 15). The results were successful, covering the expectations of the company, so it was decided to continue the project, extending it to the rest of the Generating Units. (author)

  13. Conditional prediction intervals of wind power generation

    DEFF Research Database (Denmark)

    Pinson, Pierre; Kariniotakis, Georges

    2010-01-01

    A generic method for the providing of prediction intervals of wind power generation is described. Prediction intervals complement the more common wind power point forecasts, by giving a range of potential outcomes for a given probability, their so-called nominal coverage rate. Ideally they inform...... on the characteristics of prediction errors for providing conditional interval forecasts. By simultaneously generating prediction intervals with various nominal coverage rates, one obtains full predictive distributions of wind generation. Adapted resampling is applied here to the case of an onshore Danish wind farm......, for which three point forecasting methods are considered as input. The probabilistic forecasts generated are evaluated based on their reliability and sharpness, while compared to forecasts based on quantile regression and the climatology benchmark. The operational application of adapted resampling...

  14. Aeroderivative Pratt & Whitney FT8-3 gas turbine – an interesting solution for power generation

    Directory of Open Access Journals (Sweden)

    Sorinel-Gicu TALIF

    2011-03-01

    Full Text Available The intermediate load electric power stations become more and more interesting for theelectric power market in Romania. In this context, the Combined Cycle Power Plants came as a veryattractive solution. This paper presents the results of a study regarding the use of the aeroderivativePratt & Whitney FT8-3 gas turbine, available in Romania, for the electric power generation in aCombined Cycle Power Plant. It is also analyzed the Combined Heat in Power generation with FT8-3gas turbine when saturated steam or hot water are required.

  15. Power generation from poultry litter biomass

    Energy Technology Data Exchange (ETDEWEB)

    Giaier, T.A.; Morrow, R.S. [Detroit Stoker Co., Detroit (United States)

    1999-07-01

    The following paper presents the experiences of power plants utilizing poultry litter as a boiler fuel. The combustion of poultry litter provides an innovative solution to problems such as ground water run-off contamination while producing electric power with this renewable fuel. The ash from the combustion process can be utilized for resale as a fertilizer, thereby helping to provide a closed-loop environmental cycle. As with all biomass fuels, the power generated results in a net reduction in CO{sub 2} emissions and thus contributes to the solution of current greenhouse gas problems. (author)

  16. Photocatalytic degradation of pollutants from Elcogas IGCC power station effluents.

    Science.gov (United States)

    Durán, A; Monteagudo, J M; San Martín, I; García-Peña, F; Coca, P

    2007-06-01

    The aim of this work is to improve the quality of water effluents coming from Elcogas IGCC power station (Puertollano, Spain) with the purpose of fulfilling future more demanding normative, using heterogeneous photocatalytic oxidation processes (UV/H(2)O(2)/TiO(2) or ZnO). The efficiency of photocatalytic degradation for the different catalysts (TiO(2) and ZnO) was determined from the analysis of the following parameters: cyanides, formates and ammonia content. In a first stage, the influence of two parameters (initial concentration of H(2)O(2) and amount of catalyst) on the degradation kinetics of cyanides and formates was studied based on a factorial experimental design. pH was always kept in a value >9.5 to avoid gaseous HCN formation. The degradation of cyanides and formates was found to follow pseudo-first order kinetics. Experimental kinetic constants were fitted using neural networks (NNs). The mathematical model reproduces experimental data within 90% of confidence and allows the simulation of the process for any value of parameters in the experimental range studied. Moreover, a measure of the saliency of the input variables was made based upon the connection weights of the neural networks, allowing the analysis of the relative relevance of each variable with respect to the others. Results showed that the photocatalytic process was effective, being the degradation rate of cyanides about five times higher when compared to removal of formates. Finally, the effect of lowering pH on the degradation of formates was evaluated after complete cyanides destruction was reached (10 min of reaction). Under the optimum conditions (pH 5.2, [H(2)O(2)]=40 g/l; [TiO(2)]=2g/l), 100% of cyanides and 92% of initial NH(3) concentration are degraded after 10 min, whereas 35 min are needed to degrade 98% of formates.

  17. Realisation and instrumentation of high current power station for superconducting cables testing; Realisation et instrumentation d'une station fort courant pour le test de cables supraconducteurs

    Energy Technology Data Exchange (ETDEWEB)

    Regnaud, S

    2000-05-01

    This report deals with the designing of a high current station able to test electric properties of superconductors. This test station will be used for testing the superconducting wires of large hadron collider detectors in CERN. The high current test station will have to generate high intensity continuous current in a magnetic field of 0 to 5 tesla and in temperature conditions of 4.2 K. The length of wire samples submitted to the uniform magnetic field is 300 mm and the installation is fitted with equipment able to measure the magnetic field perpendicular to either faces of the wire. The peculiarity of this station is to use a superconducting transformer in order to generate the high current. The first part of this work recalls important notions concerning superconductivity. The second part presents the high current station by describing the superconducting transformer and the sample-holder. We have studied the designing of a transformer able to yield a secondary current whose intensity reaches 100 kA, such intensity generates powerful electromagnetic forces (566 kN/m) in case of defect, so the sample-holder has to be carefully design to bear them. The third part presents the cryogenic component of the station, the instrumentation of the sample-holder and the method used to measure secondary currents. In the last part we present the performance of a prototype transformer, this prototype is able to deliver a 22 kA secondary current for a 160 A primary current, the uncertainty on the measured value of the secondary current is about 3%.

  18. FLAME MONITORING IN POWER STATION BOILERS USING IMAGE PROCESSING

    Directory of Open Access Journals (Sweden)

    K. Sujatha

    2012-05-01

    Full Text Available Combustion quality in power station boilers plays an important role in minimizing the flue gas emissions. In the present work various intelligent schemes to infer the flue gas emissions by monitoring the flame colour at the furnace of the boiler are proposed here. Flame image monitoring involves capturing the flame video over a period of time with the measurement of various parameters like Carbon dioxide (CO2, excess oxygen (O2, Nitrogen dioxide (NOx, Sulphur dioxide (SOx and Carbon monoxide (CO emissions plus the flame temperature at the core of the fire ball, air/fuel ratio and the combustion quality. Higher the quality of combustion less will be the flue gases at the exhaust. The flame video was captured using an infrared camera. The flame video is then split up into the frames for further analysis. The video splitter is used for progressive extraction of the flame images from the video. The images of the flame are then pre-processed to reduce noise. The conventional classification and clustering techniques include the Euclidean distance classifier (L2 norm classifier. The intelligent classifier includes the Radial Basis Function Network (RBF, Back Propagation Algorithm (BPA and parallel architecture with RBF and BPA (PRBFBPA. The results of the validation are supported with the above mentioned performance measures whose values are in the optimal range. The values of the temperatures, combustion quality, SOx, NOx, CO, CO2 concentrations, air and fuel supplied corresponding to the images were obtained thereby indicating the necessary control action taken to increase or decrease the air supply so as to ensure complete combustion. In this work, by continuously monitoring the flame images, combustion quality was inferred (complete/partial/incomplete combustion and the air/fuel ratio can be automatically varied. Moreover in the existing set-up, measurements like NOx, CO and CO2 are inferred from the samples that are collected periodically or by

  19. Oil use of the effluent plant ETEO (Effluent Station of Oil Treatment) as combustible for generation of energy in the power plant UG-50Hz; Utulizacao de oleo da ETEO (Estacao de Tratamento de Efluentes Oleosos) para geracao de energia na UG-50Hz

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Jose Francisco de; Nascimento, Jose Maria do; Silva, Luiz Antonio da; Salazar, Marcos Vinicios; Baptista, Reinaldo Lopes; Barros, Sueli Aguiar [Companhia Siderurgica Nacional (CSN), Volta Redonda, RJ (Brazil)

    2009-11-01

    The areas of finishing products of CSN Steel Plant generate contaminated effluents with oil and grease , that are treated in ETEO (Effluent Station of Oil Treatment). In this plant, the oil is processed to be sold for the consuming market. However, some seasons of the year, the market does not absorb the oil, and CSN is obliged to defray the burning of this oil, to not interrupt the productive process and cause an environmental impact. Because of this situation, we search alternatives for the viable use of this oil inside CSN steel plant, taking care for the security of the processes and the impact to the environment. This paper describes the details of the work and the implantation of the burning of this oil of the ETEO with BPF oil (type of petrochemical oil) as combustible in the boiler 7 of the power plant UG 50 Hz. For the implantation of this project, operational contingencies of security for equipment was prepared . Moreover, the work included chemical analyses of the oil and the conditions of the boiler using this mixing of oils. The reached results demonstrate the total viability of this project and it was proved another alternative of the use of this residue, with reduction of the fuel costs , steam costs and the electric energy generated in the power plant of CSN. (author)

  20. Year Round Operation of Autonomous, Low Power Geophysical Stations in Antarctica

    Science.gov (United States)

    Beaudoin, B. C.; White, S.; Bonnett, B.; Parker, T.; Johns, B.; Anderson, K. R.

    2009-12-01

    Year round operation of autonomous, low power geophysical stations in Antarctica presents both technical and logistical challenges. Prior to 2005, few if any autonomous seismic or GPS stations operated continuously throughout the austral winter. There are two basic environmental challenges in Antarctica beyond the logistical challenge: the margins with relatively mild temperatures but extreme winds and the Polar Plateau with extreme temperatures but relatively little wind. Large caches of lead-acid batteries can operate stations on the Antarctic margins where temperatures are relatively high, but are logistically expensive and will not survive the extreme temperatures of the Polar Plateau. Primary lithium thionyl chloride batteries have been proven to be successful and economical for use in the extreme plateau environment. These technical and logistical challenges were the focus of an IRIS/PASSCAL-UNAVCO collaboration to design power and communications for a < 5W system capable of continuous operation without intervention for two years. This collaboration has resulted in the successful operation of close to 100 GPS and seismic stations on several IPY projects with better than 80% data return. Our systems were designed to challenging logistical constrains for increased efficiency in polar operations. These year-round systems can now be deployed in a single twin otter flight. The IRIS/PASSCAL-UNAVCO collaboration has resulted in deployable systems backed by facilities with proven track records of longevity of technical field support. Our expertise and sustained engineering has resulted in a robust community product. We have significantly lowered the barriers of entry to scientists who desire year-round autonomous data collection in the Polar regions. A transparent development process with broad community support and input has resulted in a new generation of GPS and seismic systems fielded on several major IPY projects. The challenge now is how to keep the development

  1. Structural Design and Protective Methods for the 100 kW Shoreline Wave Power Station

    Institute of Scientific and Technical Information of China (English)

    游亚戈; 郑永红; 马玉久; 余志; 蒋念东

    2003-01-01

    The structural design and protective methods for the 100 kW shoreline wave power station in China are described in detail. The proper structural type is designed for effective minimization of wave loads and bending stress. Various protective devices are adopted to protect the station in the extreme conditions against excessive power of airflow, excessive torsion of the shaft, over-pressure of the chamber, over-speed of rotation, power failure, and so on. It turns out that the structural design and protective methods for the 100 kW shoreline wave power station are successful.

  2. Green power perspectives on sustainable electricity generation

    CERN Document Server

    Neiva de Figueiredo, Joao

    2014-01-01

    Green Power: Perspectives on Sustainable Electricity Generation; João Neiva de Figueiredo and Mauro GuillénAn Overview of Electricity Generation Sources; Akhil Jariwala and Saumil JariwalaGermany's Energy Revolution; José Carlos Thomaz, Jr. and Sean MichalsonChina's Energy Profile and the Importance of Coal; Julia Zheng and Xiaoting ZhengChina's Search for Cleaner Electricity Generation Alternatives; Julia Zheng and Xiaoting ZhengRenewable Energy in Spain: A Quest for Energy Security; José Normando Bezerra, Jr.Renewable Energy in French Polynesia: From Unpredictable to Energy Independence? Dia

  3. Power Generation Using Mechanical Wave Energy Converter

    Directory of Open Access Journals (Sweden)

    Srinivasan Chandrasekaran

    2012-03-01

    Full Text Available Ocean wave energy plays a significant role in meeting the growing demand of electric power. Economic, environmental, and technical advantages of wave energy set it apart from other renewable energy resources. Present study describes a newly proposed Mechanical Wave Energy Converter (MEWC that is employed to harness heave motion of floating buoy to generate power. Focus is on the conceptual development of the device, illustrating details of component level analysis. Employed methodology has many advantages such as i simple and easy fabrication; ii easy to control the operations during rough weather; and iii low failure rate during normal sea conditions. Experimental investigations carried out on the scaled model of MWEC show better performance and its capability to generate power at higher efficiency in regular wave fields. Design Failure Mode and Effect Analysis (FMEA shows rare failure rates for all components except the floating buoy.

  4. Electric power generation the changing dimensions

    CERN Document Server

    Tagare, D M

    2011-01-01

    "This book offers an analytical overview of established electric generation processes, along with the present status & improvements for meeting the strains of reconstruction. These old methods are hydro-electric, thermal & nuclear power production. The book covers climatic constraints; their affects and how they are shaping thermal production. The book also covers the main renewable energy sources, wind and PV cells and the hybrids arising out of these. It covers distributed generation which already has a large presence is now being joined by wind & PV energies. It covers their accommodation in the present system. It introduces energy stores for electricity; when they burst upon the scene in full strength are expected to revolutionize electricity production. In all the subjects covered, there are references to power marketing & how it is shaping production. There will also be a reference chapter on how the power market works"--Provided by publisher.

  5. Photovoltaic Power Generation in the Stellar Environments

    CERN Document Server

    Girish, T E

    2010-01-01

    In this paper we have studied the problem of photovoltaic power generation near selected stars in the solar neighborhood. The nature of the optical radiation from a star will depend on its luminosity,HR classification and spectral characteristics. The solar celloperation in the habitable zones of the stars is similar to AM1.0 operation near earth.Thecurrent space solar cell technology can be adopted for power generation near G,K and Mtype stars. Silicon solar cells with good near IR response are particularly suitable in theenvironments of M type stars which are most abundant in the universe. . Photovoltaicpower generation near binary stars like Sirius and Alpha Centauri is also discussed.

  6. Power Consideration in a Piezoelectric Generator

    Directory of Open Access Journals (Sweden)

    Rémi Tardiveau

    2013-01-01

    Full Text Available A piezoelectric generator converts mechanical energy into electricity and is used in energy harvesting devices. In this paper, synchronisation conditions in regard to the excitation vibration are studied. We show that a phase shift of ninety degrees between the vibration excitation and the bender’s displacement provides the maximum power from the mechanical excitation. However, the piezoelectric material is prone to power losses; hence the bender’s displacement amplitude is optimised in order to increase the amount of power which is converted into electricity. In the paper, we use active energy harvesting to control the power flow, and all the results are achieved at a frequency of 200 Hz which is well below the generator’s resonant frequency.

  7. Improvement of power quality using distributed generation

    Energy Technology Data Exchange (ETDEWEB)

    Moreno-Munoz, A.; Lopez-Rodriguez, M.A.; Flores-Arias, J.M.; Bellido-Outerino, F.J. [Universidad de Cordoba, Departamento A.C., Electronica y T.E., Escuela Politecnica Superior, Campus de Rabanales, E-14071 Cordoba (Spain); de-la-Rosa, J.J.G. [Universidad de Cadiz, Area de Electronica, Dpto. ISA, TE y Electronica, Escuela Politecnica Superior Avda, Ramon Puyol, S/N, E-11202-Algeciras-Cadiz (Spain); Ruiz-de-Adana, M. [Universidad de Cordoba, Departamento de Quimica Fisica y Termodinamica Aplicada, Campus de Rabanales, E-14071 Cordoba (Spain)

    2010-12-15

    This paper addresses how Distributed Generation (DG), particularly when configured in Combined Heat and Power (CHP) mode, can become a powerful reliability solution in highlight automated factories, especially when integrated with complimentary Power Quality (PQ) measures. The paper presents results from the PQ audit conducted at a highly automated plant over last year. It was found that the main problems for the equipment installed were voltage sags. Among all categories of electrical disturbances, the voltage sag (dip) and momentary interruption are the nemeses of the automated industrial process. The paper analyzes the capabilities of modern electronic power supplies and the convenience of embedded solution. Finally it is addressed the role of the DG/CHP on the reliability of digital factories. (author)

  8. Optimal Dispatch Strategy of a Virtual Power Plant Containing Battery Switch Stations in a Unified Electricity Market

    Directory of Open Access Journals (Sweden)

    Hao Bai

    2015-03-01

    Full Text Available A virtual power plant takes advantage of interactive communication and energy management systems to optimize and coordinate the dispatch of distributed generation, interruptible loads, energy storage systems and battery switch stations, so as to integrate them as an entity to exchange energy with the power market. This paper studies the optimal dispatch strategy of a virtual power plant, based on a unified electricity market combining day-ahead trading with real-time trading. The operation models of interruptible loads, energy storage systems and battery switch stations are specifically described in the paper. The virtual power plant applies an optimal dispatch strategy to earn the maximal expected profit under some fluctuating parameters, including market price, retail price and load demand. The presented model is a nonlinear mixed-integer programming with inter-temporal constraints and is solved by the fruit fly algorithm.

  9. Staff Draft Report. Comparative Cost of California Central Station Electricity Generation Technologies.

    Energy Technology Data Exchange (ETDEWEB)

    Badr, Magdy; Benjamin, Richard

    2003-02-11

    This Energy Commission staff draft report presents preliminary levelized cost estimates for several generic central-station electricity generation technologies. California has traditionally adopted energy policies that balance the goals of supporting economic development, improving environmental quality and promoting resource diversity. In order to be effective, such policies must be based on comprehensive and timely gathering of information. With this goal in mind, the purpose of the report is to provide comparative levelized cost estimates for a set of renewable (e.g., solar) and nonrenewable (e.g., natural gas-fired) central-station electricity generation resources, based on each technology's operation and capital cost. Decision-makers and others can use this information to compare the generic cost to build specific technology. These costs are not site specific. If a developer builds a specific power plant at a specific location, the cost of siting that plant at that specific location must be considered. The Energy Commission staff also identifies the type of fuel used by each technology and a description of the manner in which the technology operates in the generation system. The target audiences of this report are both policy-makers and anyone wishing to understand some of the fundamental attributes that are generally considered when evaluating the cost of building and operating different electricity generation technology resources. These costs do not reflect the total cost to consumers of adding these technologies to a resources portfolio. These technology characterizations do not capture all of the system, environmental or other relevant attributes that would typically be needed by a portfolio manager to conduct a comprehensive ''comparative value analysis''. A portfolio analysis will vary depending on the particular criteria and measurement goals of each study. For example, some form of firm capacity is typically needed with wind

  10. Multi-Objective Reservoir Optimization Balancing Energy Generation and Firm Power

    Directory of Open Access Journals (Sweden)

    Fang-Fang Li

    2015-07-01

    Full Text Available To maximize annual power generation and to improve firm power are important but competing goals for hydropower stations. The firm power output is decisive for the installed capacity in design, and represents the reliability of the power generation when the power plant is put into operation. To improve the firm power, the whole generation process needs to be as stable as possible, while the maximization of power generation requires a rapid rise of the water level at the beginning of the storage period. Taking the minimal power output as the firm power, both the total amount and the reliability of the hydropower generation are considered simultaneously in this study. A multi-objective model to improve the comprehensive benefits of hydropower stations are established, which is optimized by Non-dominated Sorting Genetic Algorithm-II (NSGA-II. The Three Gorges Cascade Hydropower System (TGCHS is taken as the study case, and the Pareto Fronts in different search spaces are obtained. The results not only prove the effectiveness of the proposed method, but also provide operational references for the TGCHS, indicating that there is room of improvement for both the annual power generation and the firm power.

  11. Electrical power systems for distributed generation

    Energy Technology Data Exchange (ETDEWEB)

    Robertson, T.A.; Huval, S.J. [Stewart & Stevenson Services, Inc., Houston, TX (United States)

    1996-12-31

    {open_quotes}Distributed Generation{close_quotes} has become the {open_quotes}buzz{close_quotes} word of an electric utility industry facing deregulation. Many industrial facilities utilize equipment in distributed installations to serve the needs of a thermal host through the capture of exhaust energy in a heat recovery steam generator. The electrical power generated is then sold as a {open_quotes}side benefit{close_quotes} to the cost-effective supply of high quality thermal energy. Distributed generation is desirable for many different reasons, each with unique characteristics of the product. Many years of experience in the distributed generation market has helped Stewart & Stevenson to define a range of product features that are crucial to most any application. The following paper will highlight a few of these applications. The paper will also examine the range of products currently available and in development. Finally, we will survey the additional services offered by Stewart & Stevenson to meet the needs of a rapidly changing power generation industry.

  12. Power performance of circular piezoelectric diaphragm generators

    Institute of Scientific and Technical Information of China (English)

    Kehong TANG; Junwu KAN; Taijiang PENG; Zhigang YANG; Guangming CHENG

    2008-01-01

    Energy generation performance of a piezo-electric generator depends mainly on several elements such as the structural style, boundary conditions, geo-metry parameters, materials, vibration-source frequency, and external load. To obtain the optimal energy-harvest-ing device, the Raleigh method is used to establish the analysis model of circular piezoelectric composite dia-phragms. Simply supported and clamped boundary con-ditions were considered. The relationships between the output power and the structural parameters of piezo-electric composite diaphragms, and the external load res-istance and frequency were shown. Given the correlative material parameters and boundary conditions, the output power, using structural parameters, external load, or vibrating frequency as variables, can be calculated. Simulation results show that there are optimal structural parameters and load for a composite diaphragm to achieve the maximum output power. A piezoelectric dia-phragm generator with given dimensions tends to achieve higher output power under clamped boundary conditions than that under simply supported boundary conditions.

  13. Generating units performances: power system requirements

    Energy Technology Data Exchange (ETDEWEB)

    Fourment, C.; Girard, N.; Lefebvre, H.

    1994-08-01

    The part of generating units within the power system is more than providing power and energy. Their performance are not only measured by their energy efficiency and availability. Namely, there is a strong interaction between the generating units and the power system. The units are essential components of the system: for a given load profile the frequency variation follows directly from the behaviour of the units and their ability to adapt their power output. In the same way, the voltage at the units terminals are the key points to which the voltage profile at each node of the network is linked through the active and especially the reactive power flows. Therefore, the customer will experience the frequency and voltage variations induced by the units behaviour. Moreover, in case of adverse conditions, if the units do not operate as well as expected or trip, a portion of the system, may be the whole system, may collapse. The limitation of the performance of a unit has two kinds of consequences. Firstly, it may result in an increased amount of not supplied energy or loss of load probability: for example if the primary reserve is not sufficient, a generator tripping may lead to an abnormal frequency deviation, and load may have to be shed to restore the balance. Secondly, the limitation of a unit performance results in an economic over-cost for the system: for instance, if not enough `cheap` units are able to load-following, other units with higher operating costs have to be started up. We would like to stress the interest for the operators and design teams of the units on the one hand, and the operators and design teams of the system on the other hand, of dialog and information exchange, in operation but also at the conception stage, in order to find a satisfactory compromise between the system requirements and the consequences for the generating units. (authors). 11 refs., 4 figs.

  14. Modeling of interior noise levels in large combustion turbine power stations

    Energy Technology Data Exchange (ETDEWEB)

    Hedeen, R.A. [GE Global Research, Niskayuna, NY (United States); Loud, R.L. [GE Energy, Schenectady, NY (United States)

    2007-07-01

    A study was conducted to predict noise emissions from power generating stations. In particular, the SoundPLAN4 ray-tracing program originally designed for exterior environmental noise propagation analysis, was used to predict the sound levels coming from inside combustion turbines and combined-cycle power plants. Although exterior sound levels are of interest due to their propagation into nearby communities, interior sound levels are important because of their influence on occupational noise exposure. Most regulations are concerned with an 85 dBA, 8 hour exposure. Therefore, plant designers, operators, and owners must be able to predict and control the areas in their plants where these regulations must be considered. In this study, the Raynoise 5 program was also used to analyze sound propagation. The ray-trace model considered the known sound power levels of the major pieces of equipment and was able to predict the sound distribution through the turbine hall with acceptable accuracy. The models used in this study were suitable for both compliance evaluation and noise target optimization of the individual power train components. It was concluded that the location and arrangement of the power train, off-base skids, and stand-alone equipment can be altered to control the sound level in desired areas of the plant. 7 refs., 4 figs.

  15. An ABC analysis for power generation project

    Directory of Open Access Journals (Sweden)

    Batool Hasani

    2013-07-01

    Full Text Available One of the primary concerns on performance measurement is to know how much a particular project cost. However, using traditional method on project-based products often leads to inappropriate results. In this paper, we re-examine this issue by comparing the cost of a power station construction project using ABC versus traditional method. The results of survey show that ABC method is capable of providing better estimates for overhead costs compared with traditional method. In other words, ABC method helps reduce some of the unnecessary overhead cost items and increase on some other cost components. This helps increase the relative efficiency of the system by reducing total cost of project.

  16. DESIGNING AN OPPORTUNITY FUEL WITH BIOMASS AND TIRE-DERIVED FUEL FOR COFIRING AT WILLOW ISLAND GENERATING STATION AND COFIRING SAWDUST WITH COAL AT ALBRIGHT GENERATING STATION

    Energy Technology Data Exchange (ETDEWEB)

    K. Payette; D. Tillman

    2003-10-01

    During the period July 1, 2003-September 30, 2003, Allegheny Energy Supply Co., LLC (Allegheny) proceeded with demonstration operations at the Willow Island Generating Station and improvements to the Albright Generating Station cofiring systems. The demonstration operations at Willow Island were designed to document integration of bio mass cofiring into commercial operations, including evaluating new sources of biomass supply. The Albright improvements were designed to increase the resource base for the projects, and to address issues that came up during the first year of operations. During this period, a major presentation summarizing the program was presented at the Pittsburgh Coal Conference. This report summarizes the activities associated with the Designer Opportunity Fuel program, and demonstrations at Willow Island and Albright Generating Stations.

  17. Electrokinetic Power Generation from Liquid Water Microjets

    Energy Technology Data Exchange (ETDEWEB)

    Duffin, Andrew M.; Saykally, Richard J.

    2008-02-15

    Although electrokinetic effects are not new, only recently have they been investigated for possible use in energy conversion devices. We have recently reported the electrokinetic generation of molecular hydrogen from rapidly flowing liquid water microjets [Duffin et al. JPCC 2007, 111, 12031]. Here, we describe the use of liquid water microjets for direct conversion of electrokinetic energy to electrical power. Previous studies of electrokinetic power production have reported low efficiencies ({approx}3%), limited by back conduction of ions at the surface and in the bulk liquid. Liquid microjets eliminate energy dissipation due to back conduction and, measuring only at the jet target, yield conversion efficiencies exceeding 10%.

  18. Mission Analysis for LEO Microwave Power-Beaming Station in Orbital Launch of Microwave Lightcraft

    Science.gov (United States)

    Myrabo, L. N.; Dickenson, T.

    2005-01-01

    A detailed mission analysis study has been performed for a 1 km diameter, rechargeable satellite solar power station (SPS) designed to boost 20m diameter, 2400 kg Micr,oWave Lightcraft (MWLC) into low earth orbit (LEO) Positioned in a 476 km daily-repeating oi.bit, the 35 GHz microwave power station is configured like a spinning, thin-film bicycle wheel covered by 30% efficient sola cells on one side and billions of solid state microwave transmitter elements on the other, At the rim of this wheel are two superconducting magnets that can stor,e 2000 G.J of energy from the 320 MW, solar array over a period of several orbits. In preparation for launch, the entire station rotates to coarsely point at the Lightcraft, and then phases up using fine-pointing information sent from a beacon on-board the Lightcraft. Upon demand, the station transmits a 10 gigawatt microwave beam to lift the MWLC from the earth surface into LEO in a flight of several minutes duration. The mission analysis study was comprised of two parts: a) Power station assessment; and b) Analysis of MWLC dynamics during the ascent to orbit including the power-beaming relationships. The power station portion addressed eight critical issues: 1) Drag force vs. station orbital altitude; 2) Solar pressure force on the station; 3) Station orbital lifetime; 4) Feasibility of geo-magnetic re-boost; 5) Beta angle (i..e., sola1 alignment) and power station effective area relationship; 6) Power station percent time in sun vs, mission elapsed time; 7) Station beta angle vs.. charge time; 8) Stresses in station structures.. The launch dynamics portion examined four issues: 1) Ascent mission/trajecto1y profile; 2) MWLC/power-station mission geometry; 3) MWLC thrust angle vs. time; 4) Power station pitch rate during power beaming. Results indicate that approximately 0 58 N of drag force acts upon the station when rotated edge-on to project the minimum frontal area of 5000 sq m. An ion engine or perhaps an electrodynamic

  19. Research on Low Power Marine Current Power Generation System

    Directory of Open Access Journals (Sweden)

    Dongkai Peng

    2013-09-01

    Full Text Available This study proposes a simple topological structure and power control method for a small scale stand alone marine current system, in which a diode rectifier, DC/DC boost converter for the maximum power control, battery as a storage element and a single phase inverter to link with load. The study establishes the steady-state mathematical model of marine current power generation system and derives the formula between the maximum power point and dc battery voltage. Then use the measurements of DC voltage and DC current to obtain Maximum Power Point Tracking (MPPT by controlling the duty cycle of the boost converter switch in order to simplify the system structure and the control strategies. In this case, the hill climbing searching algorithm is employed to get maximum power point and the double closed loops control strategy is used to improve the dynamic and static performance of single phase inverter. The simulation model is developed in MATLAB/Simulink. And the control method is executed in dSPACE1104 real-time platform. The simulation and experimental results demonstrate the feasibility and validity of the proposed control strategies.

  20. Next-Generation Real-Time Geodetic Station Sensor Web for Natural Hazards Research and Applications

    Science.gov (United States)

    Bock, Y.; Clayton, R. W.; Fang, P.; Geng, J.; Gutman, S. I.; Kedar, S.; Laber, J. L.; Moore, A. W.; Owen, S. E.; Small, I.; Squibb, M. B.; Webb, F.; Yu, E.

    2012-12-01

    We report on a NASA AIST project focused on better forecasting, assessing, and mitigating natural hazards, including earthquakes, tsunamis, and extreme storms and flooding through development and implementation of a modular technology for the next-generation in-situ geodetic station, and a Geodetic Sensor Web to support the flow of information from multiple stations to scientists, mission planners, decision makers, and first responders. Meaningful warnings save lives when issued within 1-2 minutes for destructive earthquakes, several tens of minutes for tsunamis, and up to several hours for extreme storms and flooding, and can be provided by on-site fusion of multiple data types and generation of higher-order data products: GPS and accelerometer measurements to estimate point displacements, and GPS and meteorological measurements to estimate moisture variability in the free atmosphere. By operating semi-autonomously, each station can provide low-latency, high-fidelity and compact data products within the constraints of narrow communications bandwidth that often accompanies natural disasters. The project encompasses the following tasks, including hardware and software components: (1) Development of a power-efficient, low-cost, plug-in Geodetic Module for fusion of data from in situ sensors including GPS, a MEMS accelerometer package, and a MEMS meteorological sensor package, for deployment at 26 existing continuous GPS stations in southern California. The low-cost modular design is scalable to the many existing continuous GPS stations worldwide. (2) Estimation of new on-the-fly data products with 1 mm precision and accuracy, including three-dimensional broadband displacements and precipitable water, by new software embedded in the Geodetic Module's processor, rather than at a central processing facility. (3) Development of a Geodetic Sensor Web to allow the semi-autonomous sensors to transmit and receive information in real time by means of redundant sensor proxy

  1. Estimate of arsenic emission amount from the coal power stations in China

    Institute of Scientific and Technical Information of China (English)

    LUO Kunli; ZHANG Xinmin; CHEN Changhe; LU Yilun

    2004-01-01

    To study the amount of arsenic emission from the coal power stations (mainly Permo-Carboniferous coal) in China in different combustion conditions, the arsenic content of the coal, the fly ash and the cinder in high- temperature power stations as well as mid-low temperature power stations have been analyzed. This note provides a rough estimate of the total amount of arsenic emission as well as emission ratio from steam coal combustion in China. The results show that by combustion of 1 t of Permo-Carbonif- erous coal (containing roughly 5 mg/kg arsenic), high-tem- perature power stations emit roughly 0.40 g arsenic into the atmosphere and the arsenic emission rate is about 7.70%; mid-low power stations emit roughly 0.15 g arsenic into the atmosphere and the arsenic emission rate is about 2.97%. A total of 600 million tons coal is burnt annually in China power stations, and the coal comes mainly from Permo- Carboniferous depositing in the North China Plate and northwest China coal mines. Taking the average arsenic content of the coal used at the value of 5 mg/kg, the total annual arsenic emission from steam coal combustion into the atmosphere is about 195.0 t. Most of the arsenic in coal can be released in the process of coal combustion, and the most of the released arsenic can be seized by the fly ash and then both of them are seized by the dust catcher of power station, so the arsenic emission ratio to the atmosphere is declined; in addition, research on the arsenic emission amount and emission rules from the coal power stations in China should go on the coal power stations with the dry-process dust catchers by the experiments results. In the wet process of dust catcher, 20% of the arsenic in the fly ash is dissolved in the water of sedimentation tank in high-temperature power station; in the mid-low temperature power station there are 70% of the arsenic in the fly ash dissolved in the water of sedimentation tank, this is an important source of arsenic pollution in

  2. Behavior study of trace elements in pulverized lignite, bottom ash, and fly ash of Amyntaio power station, Greece.

    Science.gov (United States)

    Megalovasilis, Pavlos; Papastergios, Georgios; Filippidis, Anestis

    2013-07-01

    The Kozani-Ptolemais-Amyntaio basin constitutes the principal coal field of Greece. Approximately 50% of the total power production of Greece is generated by five power stations operating in the area. Lignite samples, together with the corresponding fly ash and bottom ash were collected, over a period of 3 months, from the power plant of Amyntaio and analyzed for their content in 16 trace elements. The results indicate that Y, Nb, U, Rb, Zr, Ni, Pb, Ba, Zn, Sr, Cu, and Th demonstrate an organic affinity during the combustion of lignite, while V has an inorganic affinity. Three elements (Co, Cr, and Sc) show an intermediate affinity.

  3. NAFTA opportunities: Electrical equipment and power generation

    Energy Technology Data Exchange (ETDEWEB)

    1993-01-01

    The North American Free Trade Agreement (NAFTA) provides significant commercial opportunities in Mexico and Canada for the United States electric equipment and power generation industries, through increased goods and services exports to the Federal Electricity Commission (CFE) and through new U.S. investment in electricity generation facilities in Mexico. Canada and Mexico are the United States' two largest export markets for electrical equipment with exports of $1.53 billion and $1.51 billion, respectively, in 1992. Canadian and Mexican markets represent approximately 47 percent of total U.S. exports of electric equipment. The report presents an economic analysis of the section.

  4. Solar power generation technology, new concepts & policy

    CERN Document Server

    Reddy, P Jayarama

    2012-01-01

    This book provides an overview of the current state of affairs in the field of solar power engineering from a global perspective. In four parts, this well-researched volume informs about (1) established solar PV (photovoltaic) technologies; (2) third-generation PV technologies based on new materials with potential for low-cost large-scale production; (3) solar cell technology based on new (third-generation) concepts such as quantum dot solar cells and nano wire solar cells using silicon and compound semiconductors; and (4) economic implications and effects, as well as policies and incentives i

  5. Methods for generating hydroelectric power development alternatives

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Shoou-yuh; Liaw, Shu-liang; Sale, M.J.; Railsback, S.F.

    1989-01-01

    Hydropower development on large rivers can result in a number of environmental impacts, including potential reductions in dissolved oxygen (DO) concentrations. This study presents a methodology for generating different hydropower development alternatives for evaluation. This methodology employs a Streeter-Phelps model to simulate DO, and the Bounded Implicit Enumeration algorithm to solve an optimization model formulated to maximize hydroelectric energy production subject to acceptable DO limits. The upper Ohio River basin was used to illustrate the use and characteristics of the methodology. The results indicate that several alternatives which meet the specified DO constraints can be generated efficiently, meeting both power and environmental objectives. 17 refs., 2 figs., 1 tab.

  6. Reliability Analysis of a 3-Machine Power Station Using State Space Approach

    Directory of Open Access Journals (Sweden)

    WasiuAkande Ahmed

    2014-07-01

    Full Text Available With the advent of high-integrity fault-tolerant systems, the ability to account for repairs of partially failed (but still operational systems become increasingly important. This paper presents a systemic method of determining the reliability of a 3-machine electric power station, taking into consideration the failure rates and repair rates of the individual component (machine that make up the system. A state-space transition process for a 3-machine with 23 states was developed and consequently, steady state equations were generated based on Markov mathematical modeling of the power station. Important reliability components were deduced from this analysis. This research simulation was achieved with codes written in Excel® -VBA programming environment. System reliability using state space approach proofs to be a viable and efficient technique of reliability prediction as it is able to predict the state of the system under consideration. For the purpose of neatness and easy entry of data, Graphic User Interface (GUI was designed.

  7. Decontamination of control rod housing from Palisades Nuclear Power Station.

    Energy Technology Data Exchange (ETDEWEB)

    Kaminski, M.D.; Nunez, L.; Purohit, A.

    1999-05-03

    Argonne National Laboratory has developed a novel decontamination solvent for removing oxide scales formed on ferrous metals typical of nuclear reactor piping. The decontamination process is based on the properties of the diphosphonic acids (specifically 1-hydroxyethane-1,1-diphosphonic acid or HEDPA) coupled with strong reducing-agents (e.g., sodium formaldehyde sulfoxylate, SFS, and hydroxylamine nitrate, HAN). To study this solvent further, ANL has solicited actual stainless steel piping material that has been recently removed from an operating nuclear reactor. On March 3, 1999 ANL received segments of control rod housing from Consumers Energy's Palisades Nuclear Plant (Covert, MI) containing radioactive contamination from both neutron activation and surface scale deposits. Palisades Power plant is a PWR type nuclear generating plant. A total of eight segments were received. These segments were from control rod housing that was in service for about 6.5 years. Of the eight pieces that were received two were chosen for our experimentation--small pieces labeled Piece A and Piece B. The wetted surfaces (with the reactor's pressurized water coolant/moderator) of the pieces were covered with as a scale that is best characterized visually as a smooth, shiny, adherent, and black/brown in color type oxide covering. This tenacious oxide could not be scratched or removed except by aggressive mechanical means (e.g., filing, cutting).

  8. Abstracts of the wind power generation symposium

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    This conference provided a forum to discuss the potential for wind power in Canada's energy future. The presentations reviewed specific Ontario Power Generation (OPG) wind projects along with lessons learned and issues encountered. The Wind Development Program at OPG was reviewed in the context of its overall Green Power Program. Other presentations described the obstacles that had to be overcome by WindShare to build one of Canada's first urban wind turbines in 2002 at Exhibition Place in Toronto. The turbine is now a source of power for approximately 250 homes as well as a tourist attraction. Current advances in small wind system blades, controller and inverter technology were also discussed with reference to the operations at the FREE Wind Test Centre in Ferndale Ontario. The test facility has made advances in using small wind turbines more cost effectively. Other presentations addressed modeling and analysis of a grid connected wind energy conversion system based on frequency response data; modelling and control issues regarding power management for wind turbines; grid interconnection and power quality assessment of distributed resources; challenges and opportunities with renewable distributed energy resources; and, the use of converters in variable speed wind energy systems.

  9. 47 CFR 73.6019 - Digital Class A TV station protection of low power TV, TV translator, digital low power TV and...

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Digital Class A TV station protection of low power TV, TV translator, digital low power TV and digital TV translator stations. 73.6019 Section 73... BROADCAST SERVICES Class A Television Broadcast Stations § 73.6019 Digital Class A TV station protection...

  10. Catalytic microreactors for portable power generation

    Energy Technology Data Exchange (ETDEWEB)

    Karagiannidis, Symeon [Paul Scherer Institute, Villigen (Switzerland)

    2011-07-01

    ''Catalytic Microreactors for Portable Power Generation'' addresses a problem of high relevance and increased complexity in energy technology. This thesis outlines an investigation into catalytic and gas-phase combustion characteristics in channel-flow, platinum-coated microreactors. The emphasis of the study is on microreactor/microturbine concepts for portable power generation and the fuels of interest are methane and propane. The author carefully describes numerical and experimental techniques, providing a new insight into the complex interactions between chemical kinetics and molecular transport processes, as well as giving the first detailed report of hetero-/homogeneous chemical reaction mechanisms for catalytic propane combustion. The outcome of this work will be widely applied to the industrial design of micro- and mesoscale combustors. (orig.)

  11. Heat Management in Thermoelectric Power Generators.

    Science.gov (United States)

    Zebarjadi, M

    2016-01-01

    Thermoelectric power generators are used to convert heat into electricity. Like any other heat engine, the performance of a thermoelectric generator increases as the temperature difference on the sides increases. It is generally assumed that as more heat is forced through the thermoelectric legs, their performance increases. Therefore, insulations are typically used to minimize the heat losses and to confine the heat transport through the thermoelectric legs. In this paper we show that to some extend it is beneficial to purposely open heat loss channels in order to establish a larger temperature gradient and therefore to increase the overall efficiency and achieve larger electric power output. We define a modified Biot number (Bi) as an indicator of requirements for sidewall insulation. We show cooling from sidewalls increases the efficiency for Bi values less than one, and decreases the efficiency for Bi values larger than one.

  12. MHD power generation with fully ionized seed

    Energy Technology Data Exchange (ETDEWEB)

    Yamasaki, H.; Shioda, S.

    1977-01-01

    Recovery of power density in the regime of fully ionized seed has been demonstrated experimentally using an MHD disk generator with the effective Hall parameter up to 5.0 when the seed was fully ionized. The experiments were conducted with a shock-heated and potassium-seeded argon plasma under the following conditions: stagnation gas pressure = 0.92 atm, stagnation gas temperature = 2750 K, flow Mach number = 2.5, and seed fraction = 1.4 x 10/sup -5/. Measurements of electron-number density and spectroscopic observations of both potassium and argon lines confirmed that the recovery of power output was due to the reduction of ionization instability. This fact indicates that the successful operation of a disk generator utilizing nonequilibrium ionization seems to be possible and that the suppression of ionization instability can also provide higher adiabatic efficiency. Furthermore, the lower seed fraction offers technological advantages related to seed problems.

  13. Heat Management in Thermoelectric Power Generators

    CERN Document Server

    Zebarjadi, Mona

    2015-01-01

    Thermoelectric power generators are used to convert heat into electricity. Like any other heat engine, the performance of a thermoelectric generator increases as the temperature difference on the sides increases. It is generally assumed that as more heat is forced through the thermoelectric legs, their performance increases. Therefore, insulations are typically used to minimize the heat losses and to confine the heat transport through the thermoelectric legs. In this paper we show that to some extend it is beneficial to purposely open heat loss channels in order to establish a larger temperature gradient and therefore to increase the overall efficiency and achieve larger electric power output. We define a modified Biot number (Bi) as an indicator of requirements for sidewall insulation. We show that if Bi1, it lowers the conversion efficiency.

  14. Utility interconnection issues for wind power generation

    Science.gov (United States)

    Herrera, J. I.; Lawler, J. S.; Reddoch, T. W.; Sullivan, R. L.

    1986-01-01

    This document organizes the total range of utility related issues, reviews wind turbine control and dynamic characteristics, identifies the interaction of wind turbines to electric utility systems, and identifies areas for future research. The material is organized at three levels: the wind turbine, its controls and characteristics; connection strategies as dispersed or WPSs; and the composite issue of planning and operating the electric power system with wind generated electricity.

  15. Natural Disasters and Safety Risks at Nuclear Power Stations

    Science.gov (United States)

    Tutnova, T.

    2012-04-01

    In the aftermath of Fukushima natural-technological disaster the global opinion on nuclear energy divided even deeper. While Germany, Italy and the USA are currently reevaluating their previous plans on nuclear growth, many states are committed to expand nuclear energy output. In China and France, where the industry is widely supported by policymakers, there is little talk about abandoning further development of nuclear energy. Moreover, China displays the most remarkable pace of nuclear development in the world: it is responsible for 40% of worldwide reactors under construction, and aims at least to quadruple its nuclear capacity by 2020. In these states the consequences of Fukushima natural-technological accident will probably result in safety checks and advancement of new reactor technologies. Thus, China is buying newer reactor design from the USA which relies on "passive safety systems". It means that emergency power generators, crucial for reactor cooling in case of an accident, won't depend on electricity, so that tsunami won't disable them like it happened in the case of Fukushima. Nuclear energy managed to draw lessons from previous nuclear accidents where technological and human factors played crucial role. But the Fukushima lesson shows that the natural hazards, nevertheless, were undervalued. Though the ongoing technological advancements make it possible to increase the safety of nuclear power plants with consideration of natural risks, it is not just a question of technology improvement. A necessary action that must be taken is the reevaluation of the character and sources of the potential hazards which natural disasters can bring to nuclear industry. One of the examples is a devastating impact of more than one natural disaster happening at the same time. This subject, in fact, was not taken into account before, while it must be a significant point in planning sites for new nuclear power plants. Another important lesson unveiled is that world nuclear

  16. 77 FR 52765 - Dominion Nuclear Connecticut, Inc. Millstone Power Station, Unit 3; Exemption

    Science.gov (United States)

    2012-08-30

    ... Millstone Power Station Unit 1, a permanently defueled boiling water reactor nuclear unit, and Millstone...-water nuclear power reactors,'' requires that each power reactor meet the acceptance criteria for ECCS... Reactions at High Temperatures, III. Experimental and Theoretical Studies of the Zirconium-Water...

  17. 75 FR 52997 - Nebraska Public Power District; Cooper Nuclear Station; Exemption

    Science.gov (United States)

    2010-08-30

    ... From the Federal Register Online via the Government Publishing Office NUCLEAR REGULATORY COMMISSION Nebraska Public Power District; Cooper Nuclear Station; Exemption 1.0 Background Nebraska Public... authorizes operation of the Cooper Nuclear Station (CNS). The license provides, among other things, that...

  18. 75 FR 47856 - Nebraska Public Power District: Cooper Nuclear Station; Notice of Availability of the Final...

    Science.gov (United States)

    2010-08-09

    ... From the Federal Register Online via the Government Publishing Office NUCLEAR REGULATORY COMMISSION Nebraska Public Power District: Cooper Nuclear Station; Notice of Availability of the Final... operation for the Cooper Nuclear Station (CNS). CNS is located near Brownville, Nebraska, on the...

  19. 75 FR 10517 - Nebraska Public Power District, Cooper Nuclear Station; Exemption

    Science.gov (United States)

    2010-03-08

    ... From the Federal Register Online via the Government Publishing Office NUCLEAR REGULATORY COMMISSION Nebraska Public Power District, Cooper Nuclear Station; Exemption 1.0 Background Nebraska Public... authorizes operation of the Cooper Nuclear Station (CNS). The license provides, among other things, that...

  20. 75 FR 76055 - Nebraska Public Power District Cooper Nuclear Station; Notice of Issuance of Renewed Facility...

    Science.gov (United States)

    2010-12-07

    ... From the Federal Register Online via the Government Publishing Office NUCLEAR REGULATORY COMMISSION Docket No. 50-298; NRC-2008-0617] Nebraska Public Power District Cooper Nuclear Station; Notice of... operator of the Cooper Nuclear Station (CNS). Renewed facility operating license No. DPR-46...

  1. Economic evaluation of geothermal power generation, heating, and cooling

    Energy Technology Data Exchange (ETDEWEB)

    Kanoglu, Mehmet; Cengel, Yunus A. [Nevada Univ., Dept. of Mechanical Engineering, Reno, NV (United States)

    1999-06-01

    Economic analysis of a typical geothermal resource shows that potential revenues from geothermal heating or cooling can be much larger than those from power generation alone. Geothermal heating may generate up to about 3.1 times and geothermal absorption cooling 2.9 times as much revenue as power generation alone. Similarly, combined power generation and heating may generate about 2.1 times and combined power generation and cooling about 1.2 times as much revenue as power generation alone. Cost and payback period comparison appear to favor power generation, followed by district heating. (Author)

  2. Inspiring the Next Generation: The International Space Station Education Accomplishments

    Science.gov (United States)

    Alleyne, Camille W.; Hasbrook, Pete; Knowles, Carolyn; Chicoine, Ruth Ann; Miyagawa, Yayoi; Koyama, Masato; Savage, Nigel; Zell, Martin; Biryukova, Nataliya; Pinchuk, Vladimir; hide

    2014-01-01

    The International Space Station (ISS) has a unique ability to capture the imagination of both students and teachers worldwide. Since 2000, the presence of humans onboard ISS has provided a foundation for numerous educational activities aimed at capturing that interest and motivating study in the sciences, technology, engineering and mathematics (STEM). Over 43 million students around the world have participated in ISS-related educational activities. Projects such as YouTube Space Lab, Sally Ride Earth Knowledge-based Acquired by Middle Schools (EarthKAM), SPHERES (Synchronized Position Hold Engage and Reorient Experimental Satellites) Zero-Robotics, Tomatosphere, and MAI-75 events among others have allowed for global student, teacher and public access to space through student classroom investigations and real-time audio and video contacts with crewmembers. Educational activities are not limited to STEM but encompass all aspects of the human condition. This is well illustrated in the Uchu Renshi project, a chain poem initiated by an astronaut while in space and continued and completed by people on Earth. With ISS operations now extended to 2024, projects like these and their accompanying educational materials are available to more students around the world. From very early on in the program's history, students have been provided with a unique opportunity to get involved and participate in science and engineering projects. Many of these projects support inquiry-based learning that allows students to ask questions, develop hypothesis-derived experiments, obtain supporting evidence and identify solutions or explanations. This approach to learning is well-published as one of the most effective ways to inspire students to pursue careers in scientific and technology fields. Ever since the first space station element was launched, a wide range of student experiments and educational activities have been performed, both individually and collaboratively, by all the

  3. Phase Change Material Thermal Power Generator

    Science.gov (United States)

    Jones, Jack A.

    2013-01-01

    An innovative modification has been made to a previously patented design for the Phase Change Material (PCM) Thermal Generator, which works in water where ocean temperature alternatively melts wax in canisters, or allows the wax to re-solidify, causing high-pressure oil to flow through a hydraulic generator, thus creating electricity to charge a battery that powers the vehicle. In this modification, a similar thermal PCM device has been created that is heated and cooled by the air and solar radiation instead of using ocean temperature differences to change the PCM from solid to liquid. This innovation allows the device to use thermal energy to generate electricity on land, instead of just in the ocean.

  4. The micro power station of Verbois; Ouvrage Micro-centrale de Verbois

    Energy Technology Data Exchange (ETDEWEB)

    Quercia, P.; Martinez, J.-L. [Services industriels de Geneve, Service de l' electricite, Geneva (Switzerland)

    2005-07-01

    The policy of the public utilities of the City of Geneva includes the promotion of renewable energy and the conservation of the environment. The erection of the most important hydroelectric power plant in the canton of Geneva at Verbois, on the Rhone River dates back to the years 1938 to 1944. Several retrofits have been made since then, the last dating from 1996 to 1998. In 2000, due to ecological considerations, a fish ladder was added, resulting in a loss of generated power equivalent to a water flow of 2 m{sup 3}/s at a height of 18.35 meters. In order to compensate for this energy loss, a micro hydropower station with a maximum output power of 316 kW was added. It is fitted with a Francis turbine with horizontal axis and fixed opening; the rotation speed is 605 rpm. A reduced power output could be traced back to the deposition of solids on the grids upstream of the water supply duct. The necessary modifications are discussed.

  5. Techno-economic assessments of oxy-fuel technology for South African coal-fired power stations

    CSIR Research Space (South Africa)

    Oboirien, BO

    2014-03-01

    Full Text Available at the technical and economic viability of oxy-fuel technology for CO(sub2) capture for South African coal-fired power stations. This study presents a techno-economic analysis for six coal fired power stations in South Africa. Each of these power stations has a...

  6. 75 FR 16517 - Dominion Nuclear Connecticut, Inc.; Millstone Power Station, Unit Nos 1, 2, and 3; Exemption

    Science.gov (United States)

    2010-04-01

    ... alarm station requirements by September 30, 2010, and certain uninterruptible power supply requirements... certain uninterruptible power requirements and September 30, 2010, for certain alarm station requirements... COMMISSION Dominion Nuclear Connecticut, Inc.; Millstone Power Station, Unit Nos 1, 2, and 3; Exemption...

  7. ZERO EMISSION POWER GENERATION TECHNOLOGY DEVELOPMENT

    Energy Technology Data Exchange (ETDEWEB)

    Ronald Bischoff; Stephen Doyle

    2005-01-20

    Clean Energy Systems (CES) was previously funded by DOE's ''Vision 21'' program. This program provided a proof-of-concept demonstration that CES' novel gas generator (combustor) enabled production of electrical power from fossil fuels without pollution. CES has used current DOE funding for additional design study exercises which established the utility of the CES-cycle for retrofitting existing power plants for zero-emission operations and for incorporation in zero-emission, ''green field'' power plant concepts. DOE funding also helped define the suitability of existing steam turbine designs for use in the CES-cycle and explored the use of aero-derivative turbines for advanced power plant designs. This work is of interest to the California Energy Commission (CEC) and the Norwegian Ministry of Petroleum & Energy. California's air quality districts have significant non-attainment areas in which CES technology can help. CEC is currently funding a CES-cycle technology demonstration near Bakersfield, CA. The Norwegian government is supporting conceptual studies for a proposed 40 MW zero-emission power plant in Stavager, Norway which would use the CES-cycle. The latter project is called Zero-Emission Norwegian Gas (ZENG). In summary, current engineering studies: (1) supported engineering design of plant subsystems applicable for use with CES-cycle zero-emission power plants, and (2) documented the suitability and availability of steam turbines for use in CES-cycle power plants, with particular relevance to the Norwegian ZENG Project.

  8. Maturing Technologies for Stirling Space Power Generation

    Science.gov (United States)

    Wilson, Scott D.; Nowlin, Brentley C.; Dobbs, Michael W.; Schmitz, Paul C.; Huth, James

    2016-01-01

    Stirling Radioisotope Power Systems (RPS) are being developed as an option to provide power on future space science missions where robotic spacecraft will orbit, flyby, land or rove. A Stirling Radioisotope Generator (SRG) could offer space missions a more efficient power system that uses one fourth of the nuclear fuel and decreases the thermal footprint of the current state of the art. The RPS Program Office, working in collaboration with the U.S. Department of Energy (DOE), manages projects to develop thermoelectric and dynamic power systems, including Stirling Radioisotope Generators (SRGs). The Stirling Cycle Technology Development (SCTD) Project, located at Glenn Research Center (GRC), is developing Stirling-based subsystems, including convertors and controllers. The SCTD Project also performs research that focuses on a wide variety of objectives, including increasing convertor temperature capability to enable new environments, improving system reliability or fault tolerance, reducing mass or size, and developing advanced concepts that are mission enabling. Research activity includes maturing subsystems, assemblies, and components to prepare them for infusion into future convertor and generator designs. The status of several technology development efforts are described here. As part of the maturation process, technologies are assessed for readiness in higher-level subsystems. To assess the readiness level of the Dual Convertor Controller (DCC), a Technology Readiness Assessment (TRA) was performed and the process and results are shown. Stirling technology research is being performed by the SCTD Project for NASA's RPS Program Office, where tasks focus on maturation of Stirling-based systems and subsystems for future space science missions.

  9. Small hydro power stations, a way to secure electricity supply in Colombia. A policy evaluation using a system dynamics model

    OpenAIRE

    Perez, Vanessa Margarita

    2013-01-01

    After its deregulation in 1994, the Colombian Electricity Market (CEM) has developed satisfactorily in some sectors, especially in terms of generation and sales to large costumers and to household sector. However, around 70 % of its production capacity is based on hydroelectric power stations that are built using one or more dams. The available water in the dam (considered potential electricity) is from time to time affected by severe weather conditions which might reduce the water inflow by...

  10. Differential permeability behaviour of P9 and T22 power station Steels

    OpenAIRE

    Karimian, N a; Wilson, JWa; Peyton, AJa; Yin, W a; Liu, J. B.; Davis, CLb

    2014-01-01

    Analysis of the electromagnetic (EM) properties of power station steels, measured using a non-contact magnetic sensor, is of significance as such properties are indicative of the microstructure of the material and can be potentially exploited for non-destructive testing. In this paper, we present EM measurements of cylindrical power station steel samples (P9 and T22 grades) with different microstructures: normalised and tempered (representative of the initial condition), as normalised and aft...

  11. Approach to reducing the effect of bone-coal power station on radiation environment

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The effect of two bone-coal power stations (6 MWe) on environment wasinvestigated within the scope of the dose contribution caused by various radionucildes in different ways. It is found that the best measures to reduce the effect of bone-coal power station on radiation environment include to select a fine boiler system and a comprehensive utilization of the bone-coal cinder (BCC), soot and ash in the catchers.

  12. Approach to reducing the effect of bone—coal power station on radiation environment

    Institute of Scientific and Technical Information of China (English)

    NIShi-Ying; GUPei-Long; 等

    2002-01-01

    The effect of two bone-coal power stations(6MWe) on environment was investigated within the scope of the dose contribution caused by various radionucildes in different ways.It is found that the best measures to reduce the effect of bone-coal power station on radiation environment include to select a fine boiler system and a comprehensive utilization of the bone-coal cinder(BCC),soot and ash in the catchers.

  13. Converting Limbo Lands to Energy-Generating Stations: Renewable Energy Technologies on Underused, Formerly Contaminated Sites

    Energy Technology Data Exchange (ETDEWEB)

    Mosey, G.; Heimiller, D.; Dahle, D.; Vimmerstedt, L.; Brady-Sabeff, L.

    2007-10-01

    This report addresses the potential for using 'Limbo Lands' (underused, formerly contaminated sites, landfills, brownfields, abandoned mine lands, etc. ) as sites for renewable energy generating stations.

  14. Self-Powered Functional Device Using On-Chip Power Generation

    KAUST Repository

    Hussain, Muhammad Mustafa

    2012-01-26

    An apparatus, system, and method for a self-powered device using on-chip power generation. In some embodiments, the apparatus includes a substrate, a power generation module on the substrate, and a power storage module on the substrate. The power generation module may include a thermoelectric generator made of bismuth telluride.

  15. 75 FR 8895 - Basin Electric Power Cooperative: Deer Creek Station

    Science.gov (United States)

    2010-02-26

    ... include a new natural gas-fired combustion turbine set, a heat recovery steam generator (HRSG), and a steam turbine generator set. DATES: With this notice, RUS invites any affected Federal, State, and...

  16. Development of the ultra high efficiency thermal power generation facility

    Energy Technology Data Exchange (ETDEWEB)

    Sano, Toshihiro

    2010-09-15

    In order to prevent global warming, attention is focused on nuclear power generation and renewable energy such as wind and solar power generation. The electric power suppliers of Japan are aiming to increase the amount of nuclear and non-fossil fuel power generation over 50% of the total power generation by 2020. But this means that the remaining half will still be of thermal power generation using fossil fuel and will still play an important role. Under such circumstances, further efficiency improvement of the thermal power generation and its aggressive implementation is ongoing in Japan.

  17. Analysis and evaluation of "noise" of occupational hazards in pumped storage power station

    Science.gov (United States)

    Zhao, Xin; Yang, Hongjian; Zhang, Huafei; Chen, Tao

    2017-05-01

    Aiming at the influence of "noise" of occupational hazards on the physical health of workers, the noise intensity of a working area of a hydropower station in China was evaluated comprehensively. Under the condition of power generation, noise detection is conducted on the main patrol area of the operator, and the noise samples in different regions are analyzed and processed by the single factor analysis of variance. The results show that the noise intensity of different working areas is significantly different, in which the overall noise level of the turbine layer is the highest and beyond the national standard, the protection measures need to be strengthened and the noise intensity of the rest area is normal

  18. Mast material test program (MAMATEP). [for Solar Array Assembly of Space Station Photovoltaic Power Module

    Science.gov (United States)

    Ciancone, Michael L.; Rutledge, Sharon K.

    1988-01-01

    The MAMATEP program, which is aimed at verifying the need for and evaluating the performance of various protection techniques for the solar array assembly mast of the Space Station photovoltaic power module, is discussed. Coated and uncoated mast material samples have been environmentally tested and evaluated, before and after testing, in terms of mass and bending modulus. The protective coatings include CV-1144 silicone, a Ni/Al/InSn eutectic, and an open-weave Al braid. Long-term plasma asher results from unprotected samples indicate that, even though fiberglass-epoxy samples degrade, a protection technique may not be necessary to ensure structural integrity. A protection technique, however, may be desirable to limit or contain the amount of debris generated by the degradation of the fiberglass-epoxy.

  19. 77 FR 66484 - PSEG Nuclear LLC; Hope Creek Generating Station and Salem Generating Station, Units 1 and 2...

    Science.gov (United States)

    2012-11-05

    ... winter weather-related entry conditions are based on forecasts issued by the National Weather Service... for Nuclear Power Plant Personnel,'' endorses the Nuclear Energy Institute (NEI) report, NEI 06-11, Revision 1, ``Managing Personnel Fatigue at Nuclear Power Plants,'' with clarifications, additions and...

  20. Power Generator with Thermo-Differential Modules

    Science.gov (United States)

    Saiz, John R.; Nguyen, James

    2010-01-01

    A thermoelectric power generator consists of an oven box and a solar cooker/solar reflector unit. The solar reflector concentrates sunlight into heat and transfers the heat into the oven box via a heat pipe. The oven box unit is surrounded by five thermoelectric modules and is located at the bottom end of the solar reflector. When the heat is pumped into one side of the thermoelectric module and ejected from the opposite side at ambient temperatures, an electrical current is produced. Typical temperature accumulation in the solar reflector is approximately 200 C (392 F). The heat pipe then transfers heat into the oven box with a loss of about 40 percent. At the ambient temperature of about 20 C (68 F), the temperature differential is about 100 C (180 F) apart. Each thermoelectric module, generates about 6 watts of power. One oven box with five thermoelectric modules produces about 30 watts. The system provides power for unattended instruments in remote areas, such as space colonies and space vehicles, and in polar and other remote regions on Earth.

  1. Approach of virtual observations generation of a multi-reference GPS station network

    Science.gov (United States)

    Yu, Guorong

    2007-11-01

    The generation of virtual reference station observations to relay the corrections to the rover receiver for use with standard RTK software is one of important architectures of reference station networks RTK positioning. The approach of virtual observations generation based on a multi-reference GPS station network is presented in this paper. Ambiguities for the baselines in the reference network are determined firstly. The inter-reference-station differential spatially-correlated errors are estimated using highly accurate coordinates of the reference stations and resolved ambiguities. These spatially-correlated errors are interpolated among the network region as corrections. These network-generated corrections are used to correct the zero-differential observables of one reference station, which is usually the closest one to the rover (the so-called primary reference station). These corrected zero-differential observables, named virtual observations, are processed using conventional single reference station differential GPS algorithms. A test conducted using regional reference networks in Jiangsu(China) demonstrates the effectiveness of the approach to reduce the time to integer ambiguity resolution, and to increase the distance over which centimeter level accuracies can be achieved.

  2. Design of a photovoltaic central power station: flat-plate array

    Energy Technology Data Exchange (ETDEWEB)

    1984-02-01

    A design for a photovoltaic central power station using fixed flat-panel arrays has been developed. The 100 MW plant is assumed to be located adjacent to the Saguaro Power Station of Arizona Public Service. The design assumes high-efficiency photovoltaic modules using dendritic web cells. The modules are arranged in 5 MW subfields, each with its own power conditioning unit. The photovoltaic output is connected to the existing 115 kV utility switchyard. The site specific design allows detailed cost estimates for engineering, site preparation, and installation. Collector and power conditioning costs have been treated parametrically.

  3. Managment of concrete growth at the Mactaquac Generating Station

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, G.A. [New Brunswick Power, Fredericton (Canada); Steele, R.R. [Acres International Limited, Niagara Falls (Canada); Coulson, D.M. [Rousseau Sauve Warren Inc., Montreal (Canada)

    1995-12-31

    Remedial works undertaken to the water retaining structures of the Mactaquac project to date are summarized. The understanding of the effects of alkali-aggregate reaction on those structures and on the generating units is also discussed. The accumulated concrete growth deformations on the generating equipment has led to a major new remedial works program in the powerhouse which is being implemented. This includes diamond wire slot cutting, penstock movement joint construction and associated equipment remedial works.

  4. Application of Hybrid Optimization-Expert System for Optimal Power Management on Board Space Power Station

    Science.gov (United States)

    Momoh, James; Chattopadhyay, Deb; Basheer, Omar Ali AL

    1996-01-01

    The space power system has two sources of energy: photo-voltaic blankets and batteries. The optimal power management problem on-board has two broad operations: off-line power scheduling to determine the load allocation schedule of the next several hours based on the forecast of load and solar power availability. The nature of this study puts less emphasis on speed requirement for computation and more importance on the optimality of the solution. The second category problem, on-line power rescheduling, is needed in the event of occurrence of a contingency to optimally reschedule the loads to minimize the 'unused' or 'wasted' energy while keeping the priority on certain type of load and minimum disturbance of the original optimal schedule determined in the first-stage off-line study. The computational performance of the on-line 'rescheduler' is an important criterion and plays a critical role in the selection of the appropriate tool. The Howard University Center for Energy Systems and Control has developed a hybrid optimization-expert systems based power management program. The pre-scheduler has been developed using a non-linear multi-objective optimization technique called the Outer Approximation method and implemented using the General Algebraic Modeling System (GAMS). The optimization model has the capability of dealing with multiple conflicting objectives viz. maximizing energy utilization, minimizing the variation of load over a day, etc. and incorporates several complex interaction between the loads in a space system. The rescheduling is performed using an expert system developed in PROLOG which utilizes a rule-base for reallocation of the loads in an emergency condition viz. shortage of power due to solar array failure, increase of base load, addition of new activity, repetition of old activity etc. Both the modules handle decision making on battery charging and discharging and allocation of loads over a time-horizon of a day divided into intervals of 10

  5. Design of an off-grid hybrid PV/wind power system for remote mobile base station: A case study

    Directory of Open Access Journals (Sweden)

    Mulualem T. Yeshalem

    2017-01-01

    Full Text Available There is a clear challenge to provide reliable cellular mobile service at remote locations where a reliable power supply is not available. So, the existing Mobile towers or Base Transceiver Station (BTSs uses a conventional diesel generator with backup battery banks. This paper presents the solution to utilizing a hybrid of photovoltaic (PV solar and wind power system with a backup battery bank to provide feasibility and reliable electric power for a specific remote mobile base station located at west arise, Oromia. All the necessary modeling, simulation, and techno-economic evaluation are carried out using Hybrid Optimization Model for Electric Renewable (HOMER software. The best optimal system configurations namely PV/Battery and PV/Wind/Battery hybrid systems are compared with the conventional stand-alone diesel generator (DG system. Findings indicated that PV array and battery is the most economically viable option with the total net present cost (NPC of $\\$$57,508 and per unit cost of electricity (COE of $\\$$0.355. Simulation results show that the hybrid energy systems can minimize the power generation cost significantly and can decrease CO2 emissions as compared to the traditional diesel generator only. The sensitivity analysis is also carried out to analysis the effects of probable variation in solar radiation, wind speed, diesel price and average annual energy usage of the system load in the optimal system configurations.

  6. Integrated control of next generation power system

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2010-02-28

    The multi-agent system (MAS) approach has been applied with promising results for enhancing an electric power distribution circuit, such as the Circuit of the Future as developed by Southern California Edison. These next generation power system results include better ability to reconfigure the circuit as well as the increased capability to improve the protection and enhance the reliability of the circuit. There were four main tasks in this project. The specific results for each of these four tasks and their related topics are presented in main sections of this report. Also, there were seven deliverables for this project. The main conclusions for these deliverables are summarized in the identified subtask section of this report. The specific details for each of these deliverables are included in the “Project Deliverables” section at the end of this Final Report.

  7. Think Global, Act Local--A Power Generation Case Study

    Science.gov (United States)

    Dugdale, Pam

    2012-01-01

    This paper describes an exercise completed by sixth form college students to compare the power output from a local coal fired power station with the potential power output from renewable sources including wind farms, solar farms, and the proposed Mersey Tidal Barrage scheme. (Contains 1 figure, 1 table, and 3 photos.)

  8. Air pollution reduction in thermoelectric power stations - case study: Iquitos power plant; Reducao do impacto da poluicao do ar em usinas termeletricas - estudo de caso: usina termeletrica Iquitos

    Energy Technology Data Exchange (ETDEWEB)

    Dondero, Luz [Sao Paulo Univ., SP (Brazil). Inst. de Energia e Eletrotecnica. Programa Interunidades de Pos-graduacao em Energia]. E-mail: luz@iee.usp.br

    2000-07-01

    This work studies the environmental impacts of atmospheric emissions sent out by the Iquito's thermoelectric power station in Peru. Initially, we compute the quantitative flows (in g/s) of major gas pollutants (SO{sub 2}, SO{sub 3}, NOx, CO, CO{sub 2} and MP) emitted by the power plant. Then, we calculate the station's emission rates per kWh generated (in kilogram of pollutant /kWh). Having those inputs, we adopt EPA's SCREEN3.0 dispersion model to simulate the SO{sub 2} and NOx into the local atmosphere. We also forecast the future evolution of SO{sub 2} emissions considering the potential growth of electricity generation in the power plant. Since the Iquito's power station is located within the city's urban area, with gas emissions having direct impacts upon the local population, we study different strategies for emissions reduction from the plant. Firstly, we consider the upgrading of the existing plant with additional equipment for a more strict emission control. Then, we analyze the option of shutting down the most critical machine (in terms of atmospheric emission) in the old plant, and its substitution by a new and more efficient machine. We concluded that, although the addition of more strict control equipment is more efficient on reducing total emission, the strategy of exchanging machines is less costly and should be consider as the preferable option. (author)

  9. Integration of Renewable Generation in Power System Defence Plans

    DEFF Research Database (Denmark)

    Das, Kaushik

    , one of them being the North East area with high share of wind power generation.The aim of this study is to investigate how renewable generations like wind power can contribute to the power system defence plans. This PhD project “Integration of Renewable Generation in Power System Defence Plans...

  10. Distributed power generation using biogas fuelled microturbines

    Energy Technology Data Exchange (ETDEWEB)

    Pointon, K.; Langan, M.

    2002-07-01

    This research sought to analyse the market for small scale biogas fuelled distributed power generation, to demonstrate the concept of a biogas fuelled microturbine using the Capstone microturbine in conjunction with an anaerobic digester, and undertake a technico-economic evaluation of the biogas fuelled microturbine concept. Details are given of the experimental trials using continuous and batch digesters, and feedstocks ranging from cow and pig slurries to vegetable wastes and municipal solid waste. The yields of methane are discussed along with the successful operation of the microturbine with biogas fuels, and anaerobic digestion projects.

  11. Cycloidal tidal power generation - phase 2

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    This report describes the second phase of a study aimed at addressing the technical and economic viability of cycloidal tidal power generation with the objective of examining design optimisation, the building and testing a scale model, and the use of an enhanced model to estimated the overall system economic performance. Details are given of the analytical and physical modelling studies, the use of Computational Fluid Dynamics (CDF) analysis to understand the fluid flow through the cycloidal unit, the optimisation of the turbine blades, and performance predictions.

  12. Neutron generator power supply modeling in EMMA

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, A.C.; Farnsworth, A.V.; Montgomery, S.T.; Peery, J.S; Merewether, K.O.

    1996-12-01

    Sandia National Laboratories has prime responsibility for neutron generator design and manufacturing, and is committed to developing predictive tools for modeling neutron generator performance. An important aspect of understanding component performance is explosively driven ferroelectric power supply modeling. EMMA (ElectroMechanical Modeling in ALEGRA) is a three dimensional compile time version of Sandia`s ALEGRA code. The code is built on top of the general ALEGRA framework for parallel shock-physics computations but also includes additional capability for modeling the electric potential field in dielectrics. The overall package includes shock propagation due to explosive detonation, depoling of ferroelectric ceramics, electric field calculation and coupling with a general lumped element circuit equation system. The AZTEC parallel iterative solver is used to solve for the electric potential. The DASPK differential algebraic equation package is used to solve the circuit equation system. Sample calculations are described.

  13. Pumped storage power stations. Overview of new projects in Austria

    Energy Technology Data Exchange (ETDEWEB)

    Berger, G. [KELAG-Kaerntner Elektrizitaets-Aktiengesellschaft, Klagenfurt (Austria). Production Div.; Puerer, E. [Vorarlberger Illwerke AG, Schruns (Austria). Engineering Div.

    2008-07-01

    New framework conditions, due to the liberalisation of the electricity market and the development of renewable energy, especially wind energy with its stochastic production, led to a renaissance of pump storage technology in central Europe. Austria is lucky, first of all in providing natural water resources as well as in topography highly suitable for hydro power plants. Pump storage power plants represent even today an essential asset of the Austrian energy production. A boom for the planning and the construction of new power plants can be also observed. Currently there are pump storage power plants with a total capacity of approximately 1.100 MW under construction as well as others of approximately 1.200 MW in the stage of concrete planning. (orig.)

  14. Tampa Electric Company Polk Power Station Unit Number 1. Annual report, January--December, 1993

    Energy Technology Data Exchange (ETDEWEB)

    1994-08-01

    This report satisfies the requirements of Cooperative Agreement DE-FC21-91MC27363, novated as of March 5, 1992, to provide an annual update report on the year`s activities associated with Tampa Electric Company`s 250 MW IGCC demonstration project for the year 1993. Tampa Electric Company`s Polk Power Station Unit 1 (PPS-1) Integrated Gasification Combined Cycle (IGCC) demonstration project will use a Texaco pressurized, oxygen-blown, entrained-flow coal gasifier to convert approximately 2,000 tons per day of coal (dry basis) coupled with a combined cycle power block to produce a net 250 MW electrical power output. Approximately 50% of the raw, hot syngas is cooled to 900 F and passed through a moving bed of zinc-based sorbent which removes sulfur containing compounds from the syngas. The remaining portion of the raw, hot syngas is cooled to 400 F for conventional acid gas removal. Sulfur-bearing compounds from both cleanup systems are sent to a conventional sulfuric acid plant to produce a marketable, high-purity sulfuric acid by-product. The cleaned medium-BTU syngas from these processes is routed to the combined cycle power generation system where it is mixed with air and burned in the combustion section of the combustion turbine. Heat is extracted from the expanded exhaust gases in a heat recovery steam generator (HRSG) to produce steam at three pressure levels for use throughout the integrated process. A highly modular, microprocessor-based distributed control system (DCS) is being developed to provide continuous and sequential control for most of the equipment on PPS-1.

  15. Trace elements emission from coal-fired power stations in Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Altamirano-Bedolla, J.A.; Wong-Moreno, A.; Romo-Millares, C.A.

    1999-07-01

    This paper presents partial results of work currently in progress to determine trace elements emissions associated with the coal combustion from coal-fired power stations in Mexico. It shows the progress of the first year of a five-year project, supported by the Mexican Ministry of Energy with the aim of developing methods to obtain representative samples, perform reliable analysis and produce accurate quantification and classification of these emissions. A description of the sampling procedures and analysis performed to the coal, bottom ash, fly ash and total suspended particles in flue gas are given. Some results are provided and discussed as an example of the large amount of information that will be analyzed in the future to produce conclusions regarding trace elements from coal fired stations in Mexico. Elements such as Mercury, Arsenic, Lead, Nickel, Chromium, Cadmium, Copper, Zinc, Manganese, Cobalt, Selenium, Atimony, Vanadium, Barium, Strontium, Boron and Molybdenum were analyzed by Atomic Absorption Spectroscopy (AAS) using Flame AAS, Hydride Generation AAS and Cold Vapor AAS. Scanning Electron Microscopy and Electron Probe Microanalysis (SEM-EDX) was also used to identify some of the elements.

  16. Conceptual design of a DOT farm generator station

    NARCIS (Netherlands)

    Michailidis, D.; Diepeveen, N.F.B.

    2011-01-01

    The Delft Offshore Turbine (DOT) is a DUWIND research project that focuses on reducing the cost of offshore wind energy by bringing a radical change in offshore wind turbine technology. The main concept is to centralize electricity generation by having individual wind turbines create a flow of press

  17. 46 CFR 111.10-4 - Power requirements, generating sources.

    Science.gov (United States)

    2010-10-01

    ... services include cooking, heating, air conditioning (where installed), domestic refrigeration, mechanical... ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Power Supply § 111.10-4 Power requirements, generating sources....

  18. Identifying potential solar power generation sites using satellite apt images

    Science.gov (United States)

    Fawz-Ul-Haq, K. R.; Siddiqui, Z. R.

    1994-01-01

    In this paper, satellite APT images have been used to study cloud-cover over Pakistan, so as to determine those areas which have the least frequency of cloudiness. Such areas are likely to receive maximum insolation, and have been shown on a contour map of Pakistan. It is observed that more than half of Pakistan is highly sunny, and has many promising areas for establishing large scale solar electric power generation stations. It is further observed that, some of the productive mineral-rich areas in remote parts, such as Chagai, are highly cloud-free, therefore, it may be possible to meet their mining needs through solar energy. Thus Pakistan, on the threshold of industrialization, has high prospects of obtaining `clean' energy, free of greenhouse gases.

  19. Power consumption analysis DBD plasma ozone generator

    Science.gov (United States)

    Nur, M.; Restiwijaya, M.; Muchlisin, Z.; Susan, I. A.; Arianto, F.; Widyanto, S. A.

    2016-11-01

    Studies on the consumption of energy by an ozone generator with various constructions electrodes of dielectric barrier discharge plasma (DBDP) reactor has been carried out. This research was done to get the configuration of the reactor, that is capable to produce high ozone concentrations with low energy consumption. BDBP reactors were constructed by spiral- cylindrical configuration, plasma ozone was generated by high voltage AC voltage up to 25 kV and maximum frequency of 23 kHz. The reactor consists of an active electrode in the form of a spiral-shaped with variation diameter Dc, and it was made by using copper wire with diameter Dw. In this research, we variated number of loops coil windings N as well as Dc and Dw. Ozone concentrations greater when the wire's diameter Dw and the diameter of the coil windings applied was greater. We found that impedance greater will minimize the concentration of ozone, in contrary to the greater capacitance will increase the concentration of ozone. The ozone concentrations increase with augmenting of power. Maximum power is effective at DBD reactor spiral-cylinder is on the Dc = 20 mm, Dw = 1.2 mm, and the number of coil windings N = 10 loops with the resulting concentration is greater than 20 ppm and it consumes energy of 177.60 watts

  20. Rotary-Atomizer Electric Power Generator

    Science.gov (United States)

    Nguyen, Trieu; Tran, Tuan; de Boer, Hans; van den Berg, Albert; Eijkel, Jan C. T.

    2015-03-01

    We report experimental and theoretical results on a ballistic energy-conversion method based on a rotary atomizer working with a droplet acceleration-deceleration cycle. In a rotary atomizer, liquid is fed onto the center of a rotating flat surface, where it spreads out under the action of the centrifugal force and creates "atomized" droplets at its edge. The advantage of using a rotary atomizer is that the centrifugal force exerted on the fluid on a smooth, large surface is not only a robust form of acceleration, as it avoids clogging, but also easily allows high throughput, and produces high electrical power. We successfully demonstrate an output power of 4.9 mW and a high voltage up to 3120 V. At present, the efficiency of the system is still low (0.14%). However, the conversion mechanism of the system is fully interpreted in this paper, permitting a conceptual understanding of system operation and providing a roadmap for system optimization. This observation will open up a road for building power-generation systems in the near future.

  1. Design of Permanent Magnet Synchronous Generators for Wave Power Generation

    Institute of Scientific and Technical Information of China (English)

    方红伟; 王丹

    2016-01-01

    In this paper, a design method for ocean wave permanent magnet synchronous generator(PMSG)is proposed with new performance criteria to obtain better output performance at the cost of less permanent magnet material. Besides, a simple equivalent analytical geometry method is put forward to calculate the sizes of permanent magnets. Based on geometric and electromagnetic models, four types of rotor structures are compared, i.e., embed-ded, tangential, tile surface mount and convex surface mount structures. The designs and comparisons of machine are performed with the same permanent magnet volume. Moreover, the influences of mechanical pole-arc coeffi-cient of tile surface mount PMSG on electrical efficiency, output power, material corrosion, core loss, and torque ripple are investigated. Finite-element analysis method is applied to verify the results using Ansoft/Maxwell.

  2. Construction and preoperational test of Kashiwasaki-Kariwa Nuclear Power Station Unit No. 6

    Energy Technology Data Exchange (ETDEWEB)

    Natsume, Nobuo; Noda, Hiroshi [Tokyo Electric Power Co. (Japan)

    1996-12-31

    Unit 6 of the Kashiwazaki-Kariwa nuclear power station of Tokyo Electric Power Company, the world`s first advanced boiling water reactor (ABWR), is progressing ahead of the originally established schedule since the start of its construction in September 1991, and commercial operation is scheduled to start before the end of 1996.

  3. 75 FR 15744 - Omaha Public Power District; Fort Calhoun Station, Unit 1; Exemption

    Science.gov (United States)

    2010-03-30

    ... From the Federal Register Online via the Government Publishing Office NUCLEAR REGULATORY COMMISSION Omaha Public Power District; Fort Calhoun Station, Unit 1; Exemption 1.0 Background Omaha Public Power District (OPPD, the licensee) is the holder of Renewed Facility Operating License No. DPR-40 which authorizes operation of the Fort...

  4. Transient Processes in Electric Power Supply System for Oil Terminal with Own Gas-Turbine Power Station

    Directory of Open Access Journals (Sweden)

    A. M. Hаshimov

    2009-01-01

    Full Text Available The paper contains results of the investigations concerning influence of symmetrical and non-symmetrical short circuits at main power network on electric power supply system of a huge oil terminal which is powered by own gas-turbine power station. Calculations have been made in accordance with the IEC and IEEЕ requirements. Estimations for voltage level and distribution of short circuit current in the electric power supply system of the Sangachal oil terminal being operated in parallel with the AzerEnerji grid are presented in the paper

  5. Incorporation of a Wind Generator Model into a Dynamic Power Flow Analysis

    Directory of Open Access Journals (Sweden)

    Angeles-Camacho C.

    2011-07-01

    Full Text Available Wind energy is nowadays one of the most cost-effective and practical options for electric generation from renewable resources. However, increased penetration of wind generation causes the power networks to be more depend on, and vulnerable to, the varying wind speed. Modeling is a tool which can provide valuable information about the interaction between wind farms and the power network to which they are connected. This paper develops a realistic characterization of a wind generator. The wind generator model is incorporated into an algorithm to investigate its contribution to the stability of the power network in the time domain. The tool obtained is termed dynamic power flow. The wind generator model takes on account the wind speed and the reactive power consumption by induction generators. Dynamic power flow analysis is carried-out using real wind data at 10-minute time intervals collected for one meteorological station. The generation injected at one point into the network provides active power locally and is found to reduce global power losses. However, the power supplied is time-varying and causes fluctuations in voltage magnitude and power fl ows in transmission lines.

  6. 建设蓄能电站解决风电消纳经济性分析%Economic Analysis on Constructing Storage Stations for Consuming Wind Power

    Institute of Scientific and Technical Information of China (English)

    靳亚东; 董化宏; 马登清

    2011-01-01

    用电市场对风电消纳能力不足已经成为制约风电发展的“瓶颈”,建设抽水蓄能电站被认为是水电缺乏地区调整电源结构、解决风电消纳能力问题的有效途径,但建设抽水蓄能电站解决风电消纳的经济性问题一直是个疑问,通过详细的方案测算认为在一定的条件下,电网企业或发电公司建设抽水蓄能电站解决风电消纳是经济可行的.%The capacity shortage of electricity market for consuming wind power has been regarded as the "bottleneck" of wind power development, and the construction of pumped-storage power stations has been also considered to be an effective way to adjust power source structure and solve wind power consumption for the areas without sufficient hydropower sources, but the economy of constructing pumped -storage power stations has been a question. The economy is analyzed for constructing pumped-storage power stations to consume wind power, and the case study shows that, in certain conditions, constructing pumped-storage power stations to consume wind power by power grid and generation enterprises is feasible in economy.

  7. Lambton generating station's experience with HP turbine copper deposition

    Energy Technology Data Exchange (ETDEWEB)

    Caravaggio, M. [Lambton Generating Station, Ontario Power Generation Inc., Courtright, ON (Canada)

    2004-07-01

    This paper covers the understanding developed from, as well as the timeline and techniques that were used to address, rapid, dramatic HP turbine performance losses associated with copper deposition on two of four 500 MW coal-fired drum units at Ontario power generation's (OPG's) Lambton generating station (GS) over the last three years. The two affected units both had greater than 20 MW de-rates caused by copper deposition and 5-10% losses in HP cylinder efficiency during the period. On one unit the HP cylinder was being replaced by a dense pack HP turbine (decision made prior to identifying the copper deposition issue), and on the other unit a physical clean of the turbine was opted for, with additional study being conducted for possible chemical cleans in the future. This paper outlines Lambton's current understanding of the copper transport cycle through a drum type boiler (based on industry literature and OPG/Lambton GS operating experience), as well as Lambton's experiences to date with the solutions chosen for addressing HP turbine copper deposition. (orig.)

  8. Improving the Transient States Caused by Switching of Capacitor Banks in Power Dispatching Stations

    Directory of Open Access Journals (Sweden)

    Seyed Sajjad Salehi Ghaleh SEFID

    2014-09-01

    Full Text Available The high reactive power demand on the electrical power grid reduces the power factor and increases voltage drop. One of the compensation methods of required reactive power is the application of capacitor banks. Among the major problems with this equipment is shock, created at the moment of connection to the grid, which can cause accidents in power stations. While studying the statistical analysis of the incidents due to use of capacitor banks, this paper analyzes the shock caused by their connection, and realistically simulates a sample power station in the EMTP / WORKS software. Finally, this paper suggests useful and efficient methods to reduce the transient conditions caused by transient capacitor banks switching to the grid.

  9. In situ monitoring of animal micronuclei before the operation of Daya Bay Nuclear Power Station

    Energy Technology Data Exchange (ETDEWEB)

    Y.N. Cai; H.Y. He; L.M. Qian; G.C. Sun; J.Y. Zhao [Guangzhou College of Education, Guangzhou (China)

    1994-12-31

    Daya Bay Nuclear Power Station, a newly-built nuclear power station in southern mainland China, started its operation in 1993. We examined micro-nucleated cells of Invertibrate (Bivalves) and Vertibrate (Fish and Amphibia) in different spots within the 50km surroundings of the Power Station during 1986-1993. This paper reports the results of the investigation carried out in Dong Shan, a place 4.7km to the Power Station:Bivalves; Pteria martensil 5.1(1986),4.8(1988),4.8(1991),5,0(1993),Mytilus smardinus 4.7(1987),4.6(1988); Chamys nobilis 4.9(1987);4.9(1991),4.5(1992),4.5(1993). Fish; Therapon jarbua 0.48(1991),0.67(1992),0.47(1993). Amphibia; Bufo melanostictus 0.29 (1987), 0.34(1988),0.39(1992),0.39(1993). These results showed that the environmental situation, estimated by using the frequencies of micronucleated cells, was stable-there was no obvious chromosome damage in the animals studied. It was found that the incidence of micronucleated cells of Bivalves was higher than that of Fish and Amphibia, suggesting the epithelial cells to be more sensitive than peripheral erythrocytes to environmental genotoxic effects. The results of our studies for other spots will be reported afterward. These data can be used as the original background information to monitor the environment when the Nuclear Power Station is in operation.

  10. IMPLEMENTATION OF ENERGY LAW OF HYBRID POWER STATION FOR SOCIAL WELFARE

    Directory of Open Access Journals (Sweden)

    Dyah Ayu Widowati

    2014-11-01

    Full Text Available This study was aimed to investigate the Implementation of Energy Law of Hybrid Power Station for Social Welfare in Pantai Baru. The problem formulations are the management and utilization of hybrid power station in Pantai Baru and implementation of energy law of hybrid power station for social welfare in the fields of economy and information in Pantai Baru. Based on data analysis it is concluded that the management of hybrid power station in Pantai Baru is performed collaboratively between government and the society. The existence of hybrid power station in pantai baru has positive impacts in economy and information. Penelitian ini meneliti Pelaksanaan Hukum Energi Pembangkit Listrik Tenaga Hibrid untuk Kesejahteraan Rakyat di Bidang Ekonomi dan Informasi di Pantai Baru. Masalah yang diteliti adalah bentuk pengelolaan dan pemanfaatan pembangkit listrik tenaga hibrid di Pantai Baru dan pelaksanaan hukum energi pembangkit listrik tenaga hibrid untuk kesejahteraan rakyat di bidang ekonomi dan informasi di Pantai Baru. Berdasarkan analisis data dapat disimpulkan bahwa pengelolaan pembangkit listrik tenaga hibrid yang ada di pantai baru dilakukan secara kolaboratif, antara pemerintah dengan masyarakat. Kehadiran pembangkit listrik tenaga hibrid yang ada di pantai baru telah memberikan dampak positif di bidang ekonomi dan informasi.

  11. Development of a portable thermophotovoltaic power generator

    Science.gov (United States)

    Becker, Frederick E.; Doyle, Edward F.; Shukla, Kailash

    1997-03-01

    A 150 Watt thermophotovoltaic (TPV) power generator is being developed. The technical approach taken in the design focused on optimizing the integrated performance of the primary subsystems in order to yield high energy conversion efficiency and cost effectiveness. An important aspect of the approach is the use of a selective emitter radiating to a bandgap matched photovoltaic array to minimize thermal and optical recuperation requirements, as well as the non-recoverable heat losses. For the initial prototype system, fibrous ytterbia emitters radiating in a band centered at 980 nm are matched with high efficiency silicon photoconverters. The integrated system includes a dielectric stack filter for optical energy recovery and a ceramic recuperator for thermal energy recovery. The system has been operated with air preheat temperatures up to 1350K. The design of the system and development status are presented.

  12. How large customer direct power transaction mode give consideration to power generation cleaning and power saving

    Science.gov (United States)

    Liu, Yu; Zeng, Ming; Liu, Wei; Li, Ran

    2017-05-01

    The so-called Large Customers' Direct Power Transaction, refers to the mode that the users on high voltage level, or being seized of hold the large power or independent power distribution, have the qualification of purchasing electricity directly from the generation companies and pay reasonable electricity transmission and distribution fee to the power network enterprises because the transaction is through its transmission channel. The Direct Purchase promotes the marketization level of electricity trading, but there are some problems in its developing process, especially whether promotes the green optimal allocation of power resources, this paper aims to explore the solution.

  13. Latest developments in advanced network management and cross-sharing of next-generation flux stations

    Science.gov (United States)

    Burba, George; Johnson, Dave; Velgersdyk, Michael; Begashaw, Israel; Allyn, Douglas

    2016-04-01

    In recent years, spatial and temporal flux data coverage improved significantly and on multiple scales, from a single station to continental networks, due to standardization, automation, and management of the data collection, and better handling of the extensive amounts of generated data. However, operating budgets for flux research items, such as labor, travel, and hardware, are becoming more difficult to acquire and sustain. With more stations and networks, larger data flows from each station, and smaller operating budgets, modern tools are required to effectively and efficiently handle the entire process, including sharing data among collaborative groups. On one hand, such tools can maximize time dedicated to publications answering research questions, and minimize time and expenses spent on data acquisition, processing, quality control and overall station management. On the other hand, cross-sharing the stations with external collaborators may help leverage available funding, and promote data analyses and publications. A new low-cost, advanced system, FluxSuite, utilizes a combination of hardware, software and web-services to address these specific demands. It automates key stages of flux workflow, minimizes day-to-day site management, and modernizes the handling of data flows: (i) The system can be easily incorporated into a new flux station, or as un upgrade to many presently operating flux stations, via weatherized remotely-accessible microcomputer, SmartFlux 2, with fully digital inputs (ii) Each next-generation station will measure all parameters needed for flux computations in a digital and PTP time-synchronized mode, accepting digital signals from a number of anemometers and data loggers (iii) The field microcomputer will calculate final fully-processed flux rates in real time, including computation-intensive Fourier transforms, spectra, co-spectra, multiple rotations, stationarity, footprint, etc. (iv) Final fluxes, radiation, weather and soil data will

  14. Analysis of electromagnetic interference from power system processing and transmission components for Space Station Freedom

    Science.gov (United States)

    Barber, Peter W.; Demerdash, Nabeel A. O.; Hurysz, B.; Luo, Z.; Denny, Hugh W.; Millard, David P.; Herkert, R.; Wang, R.

    1992-01-01

    The goal of this research project was to analyze the potential effects of electromagnetic interference (EMI) originating from power system processing and transmission components for Space Station Freedom. The approach consists of four steps: (1) developing analytical tools (models and computer programs); (2) conducting parameterization (what if?) studies; (3) predicting the global space station EMI environment; and (4) providing a basis for modification of EMI standards.

  15. 43 CFR 431.6 - Power generation estimates.

    Science.gov (United States)

    2010-10-01

    ... Hoover Powerplant showing estimated power generation and estimated maintenance outages for review, and... 43 Public Lands: Interior 1 2010-10-01 2010-10-01 false Power generation estimates. 431.6 Section... THE INTERIOR GENERAL REGULATIONS FOR POWER GENERATION, OPERATION, MAINTENANCE, AND REPLACEMENT AT...

  16. Evaluation of Teaching on Clean Energy with Wind Power Generation

    OpenAIRE

    塩沢, 臣城; 石田, 聡一; 干川, 圭吾

    2000-01-01

    Evaluation of teaching material on clean energy with wind power generation is reported in this paper. A wind power generation system was developed as a teaching material in electric and electronics field in technology education of junior high school. It is shown that the teaching material was effective for students to understand the wind power generation and the clean energy.

  17. 43 CFR 418.16 - Using water for power generation.

    Science.gov (United States)

    2010-10-01

    ... 43 Public Lands: Interior 1 2010-10-01 2010-10-01 false Using water for power generation. 418.16... Operations and Management § 418.16 Using water for power generation. All use of Project water for power generation must be incidental to releases charged against Project diversions, precautionary drawdown...

  18. AC power generation from microbial fuel cells

    Science.gov (United States)

    Lobo, Fernanda Leite; Wang, Heming; Forrestal, Casey; Ren, Zhiyong Jason

    2015-11-01

    Microbial fuel cells (MFCs) directly convert biodegradable substrates to electricity and carry good potential for energy-positive wastewater treatment. However, the low and direct current (DC) output from MFC is not usable for general electronics except small sensors, yet commercial DC-AC converters or inverters used in solar systems cannot be directly applied to MFCs. This study presents a new DC-AC converter system for MFCs that can generate alternating voltage in any desired frequency. Results show that AC power can be easily achieved in three different frequencies tested (1, 10, 60 Hz), and no energy storage layer such as capacitors was needed. The DC-AC converter efficiency was higher than 95% when powered by either individual MFCs or simple MFC stacks. Total harmonic distortion (THD) was used to investigate the quality of the energy, and it showed that the energy could be directly usable for linear electronic loads. This study shows that through electrical conversion MFCs can be potentially used in household electronics for decentralized off-grid communities.

  19. QUALITY EVALUATION OF THE TPP POWER GENERATING UNITS WEAR RECONDITIONING

    Directory of Open Access Journals (Sweden)

    E. M. Farhadzadeh

    2016-01-01

    Full Text Available Reconditioning of the power generating unit worn equipment and devices is conducted during the scheduled repair period. Quality of wear reconditioning is evaluated by technical state and repair work implementation. Quality of the repair work execution characterizes logistical activities of the power station and the repair services and is rated by a five-grade scale. There are three technical conditions: adequate, subject to reservations, falling short of the technical standard documentation requirements. In practical work these constraints give place to essential ambiguity of the decision. Further to regulating techniques by way of informational support, the authors propose conducting the wear-reconditioning quality evaluation (repair quality accordingly the technical-and-economic indexes pattern of change. The paper recommends applying similarly the fivegrade system in evaluating the power generating unit technical state and distinguishes intolerable, dissatisfactory, fair, good and model estimates. The study demonstrates the assessment criteria dependence on the character of reliability and economical efficiency of performance variation after the repair with increase or decrease of the technical-and-economic indexes in reference to their mean, minimum and maximum values before the repair. The cases ascribed to intolerable quality of the wear reconditioning are those with one or more technical-and-economic indexes that not only failed to improve their values but deteriorated, and at that they became the worst amongst observable values. The model quality estimate of the wear reconditioning is allotted under condition that the power unit technical-and-economic index valuations after the repair not merely improved but also exceeded the best among those under observation. The developed method and algorithm for quality evaluation of the scheduled repair implementation contribute to practical realization of the independent monitoring. This monitoring

  20. CFD Ventilation Study for the Human Powered Centrifuge at the International Space Station

    Science.gov (United States)

    Son, Chang H.

    2011-01-01

    The Human Powered Centrifuge (HPC) is a hyper gravity facility that will be installed on board the International Space Station (ISS) to enable crew exercises under the artificial gravity conditions. The HPC equipment includes a bicycle for long-term exercises of a crewmember that provides power for rotation of HPC at a speed of 30 rpm. The crewmember exercising vigorously on the centrifuge generates the amount of carbon dioxide of several times higher than a crewmember in ordinary conditions. The goal of the study is to analyze the airflow and carbon dioxide distribution within Pressurized Multipurpose Module (PMM) cabin. The 3D computational model included PMM cabin. The full unsteady formulation was used for airflow and CO2 transport modeling with the so-called sliding mesh concept is considered in the rotating reference frame while the rest of the cabin volume is considered in the stationary reference frame. The localized effects of carbon dioxide dispersion are examined. Strong influence of the rotating HPC equipment on the CO2 distribution is detected and discussed.

  1. Computational Fluid Dynamics Ventilation Study for the Human Powered Centrifuge at the International Space Station

    Science.gov (United States)

    Son, Chang H.

    2012-01-01

    The Human Powered Centrifuge (HPC) is a facility that is planned to be installed on board the International Space Station (ISS) to enable crew exercises under the artificial gravity conditions. The HPC equipment includes a "bicycle" for long-term exercises of a crewmember that provides power for rotation of HPC at a speed of 30 rpm. The crewmember exercising vigorously on the centrifuge generates the amount of carbon dioxide of about two times higher than a crewmember in ordinary conditions. The goal of the study is to analyze the airflow and carbon dioxide distribution within Pressurized Multipurpose Module (PMM) cabin when HPC is operating. A full unsteady formulation is used for airflow and CO2 transport CFD-based modeling with the so-called sliding mesh concept when the HPC equipment with the adjacent Bay 4 cabin volume is considered in the rotating reference frame while the rest of the cabin volume is considered in the stationary reference frame. The rotating part of the computational domain includes also a human body model. Localized effects of carbon dioxide dispersion are examined. Strong influence of the rotating HPC equipment on the CO2 distribution detected is discussed.

  2. Recent developments of thermoelectric power generation

    Institute of Scientific and Technical Information of China (English)

    LUAN Weiling; TU Shantung

    2004-01-01

    One form of energy generation that is expected to be on the rise in the next several decades is thermoelectric power generation (TEPG) which converts heat directly to electricity. Compared with other methods, TEPG possesses the salient features of being compact, light-weighted,noiseless in operation, highly reliable, free of carbon dioxide emission and radioactive substances. Low current conversion efficiency and high cost, however, are some of the disadvantages. Use of TEPG is therefore justified to hightech applications associated with aerospace, military operation,tel-communication and navigation, instrumentation of unmanned vehicles monitored from remote locations. Moreover, TEPG does not contribute to the depletion of natural resource and pollution of the environment such as climate warming that has been a concern in recent times. This work is concerned with providing an overview of the state of the art of TEPG with emphases placed on assessing its current and potential application. Pointed out are the ways to fabricate high performance thermoelectric material, a hurdle to overcome for the enhancement of TEPG device efficiency.

  3. Avian radioecology on a nuclear power station site. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Levy, C.K.; Maletskos, C.J.; Youngstrom, K.A.

    1975-01-01

    A summary of a six-year avian radioecology study at the site of a nuclear power plant in Massachusetts is reported. A completed historical summary is followed by a description of mathematical models developed to calculate the effects on bird body burdens of various changes in environmental radionuclide levels. Examples are presented. Radionuclide metabolism studies in which acute doses of /sup 131/I and /sup 137/Cs were administered to four species of wild birds are presented. Radionuclides were administered both intravenously and orally; no apparent differences in uptake or elimination rates were observed between the two methods.

  4. Generation of pulsed ion beams by an inductive storage pulsed power generator

    Science.gov (United States)

    Katsuki, Sunao; Akiyama, Hidenori; Maeda, Sadao

    1990-10-01

    A pulsed power generator by an inductive energy storage system is extremely compact and light in comparison with a conventional pulsed power generator, which consists of a Marx bank and a water pulse forming line. A compact and light pulse power generator is applied to the generation of pulsed ion beams. A thin copper fuse is used an an opening switch, which is necessary in the inductive storage pulsed power generator. A magnetically insulated diode is used for the generation of ion beams. The pulsed ion beams are successfully generated by the inductive storage pulsed power generator for the first time.

  5. Computer-integrated quality management system for power stations. Computer-integriertes Qualitaetsmanagementsystem fuer Kraftwerke

    Energy Technology Data Exchange (ETDEWEB)

    Durst, K.H.; Scheurer, K.; Meinhardt, H. (Siemens AG, Offenbach (Germany). Abt. Qualitaetssicherung)

    1993-03-01

    Conventional CAQ systems, which were developed for monitoring mass production, are not very suitable for quality assurance in the construction and operation of plant and power stations. Long life products have to be monitored in plant and power station construction, which were manufactured in small batches for individually. So that the quality of these products can be monitored and can be assured economically and reliably by preventive maintenance measures, it is necessary to combine the plant documentation, repeated tests and repair or replacement measures in a 'computer-integrated quality management system'. For large complex plants, such as power stations, an operation guidance system was developed which includes all important plant information and makes it available in a user-friendly way to the concern's management. The article introduces this system. (orig.).

  6. Macro mechanical parameters' size effect of surrounding rock of Shuibuya project's underground power station

    Institute of Scientific and Technical Information of China (English)

    GUO Zhi-hua; ZHOU Chuang-bing; ZHOU Huo-ming; SHENG Qian; LENG Xian-lun

    2005-01-01

    Scale effect is one of the important aspects in the macro mechanical parameters' research of rock mass, from a new point of view, by means of lab and field rock mechanics test, establishment of E~Vp relation, classification of engineering rock mass, numerical simulation test and back analysis based on surrounding rock's displacement monitoring results of Shuibuya Project's underground power station, rock mass deformation module's size effect of surrounding rock of Shuibuya Project's undegroud power station was studied. It's shown that rock mass deformation module's scale effect of surrounding rock of Shuibuya Project's undeground power station is obvious, the rock mass deformation module to tranquilization is 20% of intact rock's. Finally the relation between rock mass deformation modules and the scale of research was established.

  7. Design of FPGA Based Neural Network Controller for Earth Station Power System

    Directory of Open Access Journals (Sweden)

    Hassen T. Dorrah

    2012-06-01

    Full Text Available Automation of generating hardware description language code from neural networks models can highly decrease time of implementation those networks into a digital devices, thus significant money savings. To implement the neural network into hardware designer, it is required to translate generated model into device structure. VHDL language is used to describe those networks into hardware. VHDL code has been proposed to implement ANNs as well as to present simulation results with floating point arithmetic of the earth station and the satellite power systems using ModelSim® PE 6.6 simulator tool. Integration between MATLAB® and VHDL is used to save execution time of computation. The results shows that a good agreement between MATLAB and VHDL and a fast/flexible feed forward NN which is capable of dealing with floating point arithmetic operations; minimum number of CLB slices; and good speed of performance. FPGA synthesis results are obtained with view RTL schematic and technology schematic from Xilinix tool. Minimum number of utilized resources is obtained by using Xilinix VERTIX5.

  8. Control strategy for multi-pump emulsion power station in coal mine face

    Institute of Scientific and Technical Information of China (English)

    LI Wen-ying; WEI Jin-hong

    2011-01-01

    Shearer and hydraulic support are matching equipments.To increase the operating speed of the shearer,the following speed of hydraulic support must be increased.This means increasing the volume of flow from emulsion power station.Analyzing the operating characteristics of hydraulic supports,the number of simultaneously operating supports is obtained by means of pressure parameter and time history at a certain time,which is a theory base for development of control system to multi-pump emulsion power station.

  9. Automating security monitoring and analysis for Space Station Freedom's electric power system

    Science.gov (United States)

    Dolce, James L.; Sobajic, Dejan J.; Pao, Yoh-Han

    1990-01-01

    Operating a large, space power system requires classifying the system's status and analyzing its security. Conventional algorithms are used by terrestrial electric utilities to provide such information to their dispatchers, but their application aboard Space Station Freedom will consume too much processing time. A novel approach for monitoring and analysis using adaptive pattern techniques is presented. This approach yields an on-line security monitoring and analysis algorithm that is accurate and fast; and thus, it can free the Space Station Freedom's power control computers for other tasks.

  10. IMPROVEMENT OF EFFICIENCY AND ECONOMY OF STEAM TURBINE POWER STATIONS BY INTEN-SIFICATION OF HEAT TRANSFER

    Directory of Open Access Journals (Sweden)

    R. F. Kelbaliev

    2005-01-01

    Full Text Available Problem concerning improvement of operational efficiency of thermal power stations by intensification of heat transfer in various elements of equipment is of current concern in power engineering. The paper contains a large body of experimental data and some proposals are given how to apply them for operating equipment at thermal power stations.

  11. 75 FR 14634 - Dominion Nuclear Connecticut, Inc.; Millstone Power Station, Unit Nos. 1, 2, and 3; Environmental...

    Science.gov (United States)

    2010-03-26

    ... part 73, for certain uninterruptible power supply requirements. The proposed action, an extension of... COMMISSION Dominion Nuclear Connecticut, Inc.; Millstone Power Station, Unit Nos. 1, 2, and 3; Environmental... Power Station, Unit Nos. 1, 2, and 3 (MPS1, MPS2, and MPS3, respectively), located in New London...

  12. The electric power engineering handbook electric power generation, transmission, and distribution

    CERN Document Server

    Grigsby, Leonard L

    2012-01-01

    Featuring contributions from worldwide leaders in the field, the carefully crafted Electric Power Generation, Transmission, and Distribution, Third Edition (part of the five-volume set, The Electric Power Engineering Handbook) provides convenient access to detailed information on a diverse array of power engineering topics. Updates to nearly every chapter keep this book at the forefront of developments in modern power systems, reflecting international standards, practices, and technologies. Topics covered include: * Electric Power Generation: Nonconventional Methods * Electric Power Generation

  13. The behaviour of coal blends in power station boilers

    Energy Technology Data Exchange (ETDEWEB)

    Livingston, W.R.; Horne, P.A.; McGhee, B.F.; Gibson, J.R. [Mitsui Babcock Energy Ltd., Renfrew (United Kingdom)

    1998-12-31

    The milling characteristics of coal blends were studied to provide quantitative information which allows the calculation of the Hardgrove Index (HGI) values of coal blends from those of the constituent coals; to provide data on the power requirement to produce a given mill output fineness, and abrasion rates of mill components when milling coal blends, relative to the behaviour of the constituent coals; to investigate the combustion behaviour of coal blends in pulverized fuel-fired systems by carrying out testwork in a semi-industrial combustion test facility, and to assess the deposition characteristics and the potential for utilization of the ashes produced by the combustion of coal blends. It was found that both the HGI and the Abrasion Index values of coals are additive properties. There were linear correlations between the slope of the Rosin-Rammler plot of the Mini-mill product size distribution and both the blend compositions and the HGI values of the coals and coal blends. Investigations showed that the fusion behaviour of the coal ash blends is rather complex, and that the characteristic ash fusion temperature are not additive in a simple way. A number of correlations were found between the ash fusion temperatures of the coals and coal ash blends. 1 ref., 45 figs., 10 tabs., 1 app.

  14. Integration of Renewable Generation in Power System Defence Plans

    OpenAIRE

    Das, Kaushik; Sørensen, Poul Ejnar; Anca Daniela HANSEN; Abildgaard, Hans

    2016-01-01

    Increasing levels of penetration of wind power and other renewable generations in European power systems pose challenges to power system security. The power system operators are continuously challenged especially when generations from renewables are high thereby reducing online capacity of conventional controllable generations to minimum. In such operation hours, the system is typically more vulnerable to disturbances in general and major disturbances in particular. This was the case in the m...

  15. Time Averaged Transmitter Power and Exposure to Electromagnetic Fields from Mobile Phone Base Stations

    Directory of Open Access Journals (Sweden)

    Alfred Bürgi

    2014-08-01

    Full Text Available Models for exposure assessment of high frequency electromagnetic fields from mobile phone base stations need the technical data of the base stations as input. One of these parameters, the Equivalent Radiated Power (ERP, is a time-varying quantity, depending on communication traffic. In order to determine temporal averages of the exposure, corresponding averages of the ERP have to be available. These can be determined as duty factors, the ratios of the time-averaged power to the maximum output power according to the transmitter setting. We determine duty factors for UMTS from the data of 37 base stations in the Swisscom network. The UMTS base stations sample contains sites from different regions of Switzerland and also different site types (rural/suburban/urban/hotspot. Averaged over all regions and site types, a UMTS duty factor  for the 24 h-average is obtained, i.e., the average output power corresponds to about a third of the maximum power. We also give duty factors for GSM based on simple approximations and a lower limit for LTE estimated from the base load on the signalling channels.

  16. Time averaged transmitter power and exposure to electromagnetic fields from mobile phone base stations.

    Science.gov (United States)

    Bürgi, Alfred; Scanferla, Damiano; Lehmann, Hugo

    2014-08-07

    Models for exposure assessment of high frequency electromagnetic fields from mobile phone base stations need the technical data of the base stations as input. One of these parameters, the Equivalent Radiated Power (ERP), is a time-varying quantity, depending on communication traffic. In order to determine temporal averages of the exposure, corresponding averages of the ERP have to be available. These can be determined as duty factors, the ratios of the time-averaged power to the maximum output power according to the transmitter setting. We determine duty factors for UMTS from the data of 37 base stations in the Swisscom network. The UMTS base stations sample contains sites from different regions of Switzerland and also different site types (rural/suburban/urban/hotspot). Averaged over all regions and site types, a UMTS duty factor for the 24 h-average is obtained, i.e., the average output power corresponds to about a third of the maximum power. We also give duty factors for GSM based on simple approximations and a lower limit for LTE estimated from the base load on the signalling channels.

  17. Effect of Hurricane Andrew on the Turkey Point Nuclear Generating Station from August 20--30, 1992. [Final report

    Energy Technology Data Exchange (ETDEWEB)

    Hebdon, F.J. [Institute of Nuclear Power Operations, Atlanta, GA (United States)

    1993-03-01

    On August 24, 1992, Hurricane Andrew, a Category 4 hurricane, struck the Turkey Point Electrical Generating Station with sustained winds of 145 mph (233 km/h). This is the report of the team that the US Nuclear Regulatory Commission (NRC) and the Institute of Nuclear Power Operations (INPO) jointly sponsored (1) to review the damage that the hurricane caused the nuclear units and the utility`s actions to prepare for the storm and recover from it, and (2) to compile lessons that might benefit other nuclear reactor facilities.

  18. A novel concentrator with zero-index metamaterial for space solar power station

    Science.gov (United States)

    Huang, Jin; Chu, Xue-mei; Fan, Jian-yu; Jin, Qi-bao; Duan, Zhu-zhu

    2017-03-01

    Space solar power station (SSPS) is a comprehensive system that continuously collects solar energy in space and transmits it to ground with a wireless power transmission (WPT) system. These systems have great potential to provide large-scale energy. To increase the efficiency and reduce the weight and cost of the photovoltaic (PV) components, a huge light-weighted concentrator was introduced in the latest SSPS concepts, such as integrated symmetrical concentrator (ISC) and arbitrarily large phased array (ALPHA). However, for typical SSPS running in Geostationary Earth Orbit (GEO), the sunlight direction varies with time, leading to a great challenge for concentrator design. In ISC, the two-dimensional mast is used to realize sun-tracking. However, a multi-thousand-ton structure is difficult to control precisely in space. For this reason, ALPHA comprises a large number of individually pointed thin-film reflectors to intercept sunlight, mounted on the non-moving structure. However, the real-time adjustment of the thousands of reflectors is still an open problem. Furthermore, the uniformity of the time of the power generation (UTPG) is another factor evaluating the system. Therefore, this paper proposes a novel concentrator based on zero-index metamaterial (ZIM) called Thin-film Energy Terminator (SSPS-TENT). This will aid the control of the massive reflectors while avoiding the rotation of the overall system, the control of the massive reflectors and the influence of the obliquity of the ecliptic. Also, an optimization design method is proposed to increase its solar energy collecting efficiency (ECE) and flux distribution (FD). The ray-tracing simulation results show that the ECE is more than 96% of the day. In terms of the FD, the uniformity varies from 0.3057 to 0.5748. Compared with ALPHA, the UTPG is more stable.

  19. Second periodic safety review of Angra Nuclear Power Station, unit 1

    Energy Technology Data Exchange (ETDEWEB)

    Martins, Carlos F.O.; Crepaldi, Roberto; Freire, Enio M., E-mail: ottoncf@tecnatom.com.br, E-mail: emfreire46@gmail.com, E-mail: robcrepaldi@hotmail.com [Tecnatom do Brasil Engenharia e Servicos Ltda, Rio de Janeiro, RJ (Brazil); Campello, Sergio A., E-mail: sacampe@eletronuclear.gov.br [Eletrobras Termonuclear S.A. (ELETRONUCLEAR), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    This paper describes the second Periodic Safety Review (PSR2-A1) of Angra Nuclear Power Station, Unit 1, prepared by Eletrobras Eletronuclear S.A. and Tecnatom do Brasil Engenharia e Servicos Ltda., during Jul.2013-Aug.2014, covering the period of 2004-2013. The site, in Angra dos Reis-RJ, Brazil, comprises: Unit 1, (640 MWe, Westinghouse PWR, operating), Unit 2 (1300 MWe, KWU/Areva, operating) and Unit 3 (1405 MWe, KWU/Areva, construction). The PSR2-A1 attends the Standards 1.26-Safety in Operation of Nuclear Power Plants, Brazilian Nuclear Regulatory Commission (CNEN), and IAEA.SSG.25-Periodic Safety Review of Nuclear Power Plants. Within 18 months after each 10 years operation, the operating organization shall perform a plant safety review, to investigate the evolution consequences of safety code and standards, regarding: Plant design; structure, systems and components behavior; equipment qualification; plant ageing management; deterministic and probabilistic safety analysis; risk analysis; safety performance; operating experience; organization and administration; procedures; human factors; emergency planning; radiation protection and environmental radiological impacts. The Review included 6 Areas and 14 Safety Parameters, covered by 33 Evaluations.After document evaluations and discussions with plant staff, it was generated one General and 33 Specific Guide Procedures, 33 Specific and one Final Report, including: Description, Strengths, Deficiencies, Areas for Improvement and Conclusions. An Action Plan was prepared by Electronuclear for the recommendations. It was concluded that the Unit was operated within safety standards and will attend its designed operational lifetime, including possible life extensions. The Final Report was submitted to CNEN, as one requisite for renewal of the Unit Permanent Operation License. (author)

  20. Navajo Generating Station and Federal Resource Planning; Volume 1: Sectoral, Technical, and Economic Trends

    Energy Technology Data Exchange (ETDEWEB)

    Hurlbut, David [National Renewable Energy Lab. (NREL), Golden, CO (United States); Haase, Scott [National Renewable Energy Lab. (NREL), Golden, CO (United States); Barrows, Clayton [National Renewable Energy Lab. (NREL), Golden, CO (United States); Bird, Lori [National Renewable Energy Lab. (NREL), Golden, CO (United States); Brinkman, Greg [National Renewable Energy Lab. (NREL), Golden, CO (United States); Cook, Jeff [National Renewable Energy Lab. (NREL), Golden, CO (United States); Day, Megan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Diakov, Victor [National Renewable Energy Lab. (NREL), Golden, CO (United States); Hale, Elaine [National Renewable Energy Lab. (NREL), Golden, CO (United States); Keyser, David [National Renewable Energy Lab. (NREL), Golden, CO (United States); Lopez, Anthony [National Renewable Energy Lab. (NREL), Golden, CO (United States); Mai, Trieu [National Renewable Energy Lab. (NREL), Golden, CO (United States); McLaren, Joyce [National Renewable Energy Lab. (NREL), Golden, CO (United States); Reiter, Emerson [National Renewable Energy Lab. (NREL), Golden, CO (United States); Stoll, Brady [National Renewable Energy Lab. (NREL), Golden, CO (United States); Tian, Tian [National Renewable Energy Lab. (NREL), Golden, CO (United States); Cutler, Harvey [Colorado State Univ., Fort Collins, CO (United States); Bain, Dominique [Northern Arizona Univ., Flagstaff, AZ (United States); Acker, Tom [Northern Arizona Univ., Flagstaff, AZ (United States)

    2016-11-01

    This study for the U.S. Bureau of Reclamation examines conditions in the electricity sector that are likely to affect federal decisions with respect to Navajo Generating Station (NGS), the largest coal-fired power plant operating in the western United States. The federal government owns 24.3% of the 2.25-gigawatt plant, which amounts to 547 megawatts (MW) of capacity. By focusing on the unique public interests that depend on the federal share of NGS, this baseline study can help the federal government develop a road map for meeting all of its goals with respect to water delivery, clean energy, emission reduction, and economic development. There is no recommendation for action in this report. Rather, its aim is to provide a credible, thorough description of baseline conditions that might affect federal decisions regarding NGS. It describes facts and trends embedded in current data, but there are no conclusions about how Reclamation or DOI should respond to the trends. The interdependencies among the many sectoral trends and federal goals are complex, and the aim of this study is to provide a foundation from which options can be tested in a deliberate manner.

  1. Aging management program of the reactor building concrete at Point Lepreau Generating Station

    Science.gov (United States)

    Aldea, C.-M.; Shenton, B.; Demerchant, M. M.; Gendron, T.

    2011-04-01

    In order for New Brunswick Power Nuclear (NBPN) to control the risks of degradation of the concrete reactor building at the Point Lepreau Generating Station (PLGS) the development of an aging management plan (AMP) was initiated. The intention of this plan was to determine the requirements for specific structural components of concrete of the reactor building that require regular inspection and maintenance to ensure the safe and reliable operation of the plant. The document is currently in draft form and presents an integrated methodology for the application of an AMP for the concrete of the reactor building. The current AMP addresses the reactor building structure and various components, such as joint sealant and liners that are integral to the structure. It does not include internal components housed within the structure. This paper provides background information regarding the document developed and the strategy developed to manage potential degradation of the concrete of the reactor building, as well as specific programs and preventive and corrective maintenance activities initiated.

  2. Aging management program of the reactor building concrete at Point Lepreau Generating Station

    Directory of Open Access Journals (Sweden)

    Gendron T.

    2011-04-01

    Full Text Available In order for New Brunswick Power Nuclear (NBPN to control the risks of degradation of the concrete reactor building at the Point Lepreau Generating Station (PLGS the development of an aging management plan (AMP was initiated. The intention of this plan was to determine the requirements for specific structural components of concrete of the reactor building that require regular inspection and maintenance to ensure the safe and reliable operation of the plant. The document is currently in draft form and presents an integrated methodology for the application of an AMP for the concrete of the reactor building. The current AMP addresses the reactor building structure and various components, such as joint sealant and liners that are integral to the structure. It does not include internal components housed within the structure. This paper provides background information regarding the document developed and the strategy developed to manage potential degradation of the concrete of the reactor building, as well as specific programs and preventive and corrective maintenance activities initiated.

  3. Micro-ionics: next generation power sources.

    Science.gov (United States)

    Tuller, Harry L; Litzelman, Scott J; Jung, Woochul

    2009-05-07

    The desire for ever smarter systems-on-a-chip and plug-free portable electronics with longer operating times between recharge has stimulated growing interest in micro-ionic systems. The use of thin film and photolithographic processing techniques, commonly at temperatures considerably below those utilized in conventional ceramics processing methods, leads to ionic or mixed ionic-electronic materials with nanosized dimensions. The implications for nanosized grains on the conductivity of thin film solid oxide electrolytes are examined. Grain boundary engineering, as a means of controlling and ultimately enhancing transport along and across grain boundaries, becomes essential given that such boundaries often dominate the transport properties of such nano-dimensioned materials. Heterogeneous doping by selective in-diffusion along grain boundaries was introduced as a potentially powerful means of achieving this. This is coupled with the modeling of space charge distributions at such boundaries, taking into account possible dopant segregation to the boundaries. The use of lithographic methods for generating geometrically well defined structures is used to illustrate how one can achieve a much improved understanding of electrode processes in SOFC structures. Indeed, the more idealized structures achievable by application of microelectronic processing provide a marvelous opportunity to uncover the science underlying the technology of micro- and ultimately macro-ionics.

  4. Next Generation Hydrogen Station Composite Data Products: All Stations (Retail and Non-Retail Combined), Data through Quarter 3 of 2016

    Energy Technology Data Exchange (ETDEWEB)

    Sprik, Sam [National Renewable Energy Lab. (NREL), Golden, CO (United States); Kurtz, Jennifer [National Renewable Energy Lab. (NREL), Golden, CO (United States); Ainscough, Chris [National Renewable Energy Lab. (NREL), Golden, CO (United States); Saur, Genevieve [National Renewable Energy Lab. (NREL), Golden, CO (United States); Peters, Michael [National Renewable Energy Lab. (NREL), Golden, CO (United States); Jeffers, Matthew [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2017-03-06

    This publication includes 87 composite data products (CDPs) produced for next generation hydrogen stations with data through the third quarter of 2016. These CDPs include data for all stations in NREL's evaluation (retail and non-retail combined).

  5. Next Generation Hydrogen Station Composite Data Products: All Stations (Retail and Non-Retail Combined), Data through Quarter 4 of 2016

    Energy Technology Data Exchange (ETDEWEB)

    Sprik, Sam [National Renewable Energy Lab. (NREL), Golden, CO (United States); Kurtz, Jennifer [National Renewable Energy Lab. (NREL), Golden, CO (United States); Ainscough, Chris [National Renewable Energy Lab. (NREL), Golden, CO (United States); Saur, Genevieve [National Renewable Energy Lab. (NREL), Golden, CO (United States); Peters, Michael [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2017-05-31

    This publication includes 90 composite data products (CDPs) produced for next generation hydrogen stations with data through the fourth quarter of 2016. These CDPs include data for all stations in NREL's evaluation (retail and non-retail combined).

  6. Diversion at small hydro-electric power stations; Forbislipping ved smaa vannkraftverk

    Energy Technology Data Exchange (ETDEWEB)

    Noren, Knut E.; Elstad, Ivar K.

    2008-07-01

    At a shut down caused by, for instance, a power shortage at a power station, the electric aggregate will stop and there will be a quick change in the flow of water downstream of the power station. This situation gives undesirable environmental effects, especially with regards to fish. The fish must have the opportunity to withdraw to deep pools, to avoid running aground. The goal of this report is to present good ideas to design diversion stations that reduce the environmental effects to an acceptable level, which is especially important in anadromous waterways, simultaneously not costing too much. The demand for diversion should be clarified with the authorities as soon as possible. By taking into account the power stations dimensions and foundation needs early on in the planning phase, the cost will be minimized. As a rule NVE currently demand that a diversion installation must have a capacity of 50 % of the turbines full flow of water. This is to avoid large changes in the flow of water downstream of the power station. In addition to the demand on the maximum capacity of the diversion installation, there should also be posed a demand that the calculation of the rate of flow should be kept within 50 % of the total rate of flow before the shut down. This is possible to achieve with the help of software control without the operational drawbacks caused by slow regulation being too great. Calculations carried out show that also with loading operation after shut down should have a relatively slow rate of flow. It is recommended that the short term rate of flow increase should be no more than 50 % of the rate of flow before the shut down or the stationary rate of flow before the turbines are started. To ensure the diversion with loading operation at small power stations it is recommended to use standard valves as much as possible, possibly with an energy dissipater that often can be manufactured locally. The installation should be arranged in such a way that the

  7. Power Electronics for the Next Generation Wind Turbine System

    DEFF Research Database (Denmark)

    Ma, Ke

    The wind power generation has been steadily growing both for the total installed capacity and for the individual turbine size. Due to much more significant impacts to the power grid, the power electronics, which can change the behavior of wind turbines from an unregulated power source to an active...... generation unit, are becoming crucial in the wind turbine system. The objective of this project is to study the power electronics technology used for the next generation wind turbines. Some emerging challenges as well as potentials like the cost of energy and reliability are going to be addressed. First...... better control performance under the unbalanced AC source. It is concluded that power electronics will play more important role and regulate all the generated power in the next generation wind turbine system. In this case, the stress in the converter components becomes more critical because the power...

  8. Reactive Power Support of Electrical Vehicle Charging Station Upgraded with Flywheel Energy Storage System

    DEFF Research Database (Denmark)

    SUN, BO; Dragicevic, Tomislav; Savaghebi, Mehdi

    2015-01-01

    the operation of each component in the system. As a result, the charging station could supply the reactive power support to the utility grid without compromising the charging algorithm and preserve the battery’s lifetime. Finally, the real-time simulation results based on dSPACE1006 verifies the proposed......Electrical vehicles (EVs) are presenting increasingly potential to replace the conventional fossil fuel based vehicles due to environmental friendly characteristic. Accordingly, Charging Stations (CS), as an intermediate between grid and large numbers of EVs, are supposed to have more critical...... influence on future smart transportation network. This paper explores an off-board charging station upgraded with flywheel energy storage system that could provide a reactive power support to the grid utility. A supervisory control scheme based on distributed bus signaling is proposed to coordinate...

  9. Research on Comparisons of New Clean Power Generation Technologies

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    On the basis of introducing clean power generation technologies, the author calculated and analyzed the investment, economy and environmental protection of these technologies, posed his views of giving the priorities to the development of supercritical and ultra-supercritical pressure coal-fired power generation technologies and taking vigorous action to nuclear power generation technology within the following 5-10 years, exploiting wind power within the following 10-15 years, and suggested that the installed capacity of nuclear power reach 80-100 GW and that of wind power reach 50-80 GW by 2020.

  10. New fossil-fired power stations in Europe. Status and perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Benesch, Wolfgang A. [Evonik Energy Services, Essen (Germany); Pasini, Sauro [Enel Engineering and Innovation Research, Pisa (Italy)

    2011-07-01

    The security of electricity supply in Europe can only be assured by a well-balanced energy mix. To ensure the increasing amount of stochastic renewable sources like e.g. wind and solar power, economically competitive coal- and gas-fired power stations are needed. Nevertheless, currently more and more projects are stopped and postponed. In that context questions like: What is the background? What is the current situation? What should be? What are the causes? What is needed? are discussed. (orig.)

  11. Study of mercury in by-products from a Dutch co-combustion power station

    OpenAIRE

    Rallo, Manuela; López Antón, María Antonia; Meij, Ruud; Perry, Ron; Maroto Valer, Mercedes

    2010-01-01

    [EN] Fly ashes and gypsum are one of the main wastes produced in coal-fired power stations which may be sent to landfills for their disposal. In this work, leaching and speciation of mercury in fly ashes and gypsum from a modern co-combustion power plant equipped with a selective catalytic reduction (SCR) unit in the Netherlands were studied. The mercury leachable contents were checked against different regulations, including Dutch, German and the Council Directive 2003/33/EC. The speciation ...

  12. The changing face of international power generation

    Energy Technology Data Exchange (ETDEWEB)

    Lindsay, I. [World Energy Council, London (United Kingdom)

    1997-12-31

    The author limits his remarks to a discussion of the international generator`s marketplace, especially aimed at the developing countries. He discusses future global electricity demand, generating capacity build, its financing issues, and to the commercial generating opportunities which now abound outside the US.

  13. Test on the 30kW Vibrating Wave-power Station Accepted in China

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    To meet the demand of island residents on the electric power for their daily lives, a 30kW vibrating wavepower station, designed and built by the Oceanic Technology Research Institute of China National Bureau of Ocean, is presently conducted with test in Jimo city of Shangdong province, and accepted by China National Bureau of Ocean and China's Academy of Science.

  14. 75 FR 16523 - FirstEnergy Nuclear Operating Company; Davis-Besse Nuclear Power Station; Exemption

    Science.gov (United States)

    2010-04-01

    ... COMMISSION FirstEnergy Nuclear Operating Company; Davis-Besse Nuclear Power Station; Exemption 1.0 Background FirstEnergy Nuclear Operating Company (FENOC, the licensee) is the holder of Facility Operating License... M.S. Fertel, Nuclear Energy Institute). The licensee's request for an exemption is...

  15. Influence of Frequency Converters on Insulation of Power Supply Cables at Oil-Producing Stations

    Directory of Open Access Journals (Sweden)

    D. I. Zalizny

    2011-01-01

    Full Text Available The paper considers consequences of negative frequency converter influence on insulation of  power supply cables used for submersible installations of electric-centrifugal pumps at oil-producing stations. The possible approaches to the solution of the problem are proposed on the basis of a harmonic analysis of actually measured voltages and currents in a cable.  

  16. MODELING OF WIND LOADS ACTING ON THE WIND POWER STATION CONSTRUCTION OF THE COMBINED TYPE

    Directory of Open Access Journals (Sweden)

    Bukhtoyarova E. S.

    2014-04-01

    Full Text Available The article presents the solution of questions about the intensity of wind loads acting on the wind power station of the combined type in relation to the conditions of the Rostov region on the basis of the structural dynamic simulation

  17. Fatigue Life Prediction of Mooring Chains for a Floating Tidal Current Power Station

    Institute of Scientific and Technical Information of China (English)

    Fengmei Jing; Liang Zhang; Zhong Yang

    2012-01-01

    As a kind of clean and renewable energy,tidal current energy is becoming increasingly popular all over the world with the shortage of energy and environmental problems becoming more and more severe.A floating tidal current power station is a typical type of tidal current power transformers which can sustain the loads of wind,waves,and current,and even the extreme situation of a typhoon.Therefore,the mooring system must be reliable enough to keep the station operating normally and to survive in extreme situations.The power station examined in this paper was installed at a depth of 40 m.A 44 mm-diameter R4-RQ4 chain was chosen,with a 2 147 kN minimum break strength and 50 kN pretension.Common studless link chain was used in this paper.Based on the Miner fatigue cumulative damage rule,S-N curves of chains,and MOSES software,a highly reliable mooring system was designed and analyzed.The calculation results show that the mooring system designed is reliable throughout a 10-year period.It can completely meet the design requirements of American Petroleum institution (API).Therefore,the presented research is significant for advancing the design of this kind of power station.

  18. The NASA-Lewis terrestrial photovoltaics program. [solar cell power system for weather station

    Science.gov (United States)

    Bernatowicz, D. T.

    1973-01-01

    Research and technology efforts on solar cells and arrays having relevance to terrestrial uses are outline. These include raising cell efficiency, developing the FEP-covered module concept, and exploring low cost cell concepts. Solar cell-battery power systems for remote weather stations have been built to demonstrate the capabilities of solar cells for terrestrial applications.

  19. 77 FR 59679 - Central Vermont Public Service Corporation (Millstone Power Station, Unit 3); Order Approving...

    Science.gov (United States)

    2012-09-28

    .... (DNC), Central Vermont Public Service Corporation (CVPS) and Massachusetts Municipal Wholesale Electric Company (MMWE) (collectively ``the licensees'' or ``DNC, Inc., et al.'') are the co-holders of the Renewed... Power Station, Unit 3 (MPS3). CVPS is a non-operating owner of a 1.7303% interest in MPS3. DNC is...

  20. Technological scheme for the waste-free treatment of thermal power station ash

    Energy Technology Data Exchange (ETDEWEB)

    Tyurnikova, V.I.; Krasnikova, N.A.; Panin, A.S.; Konovalenko, P.F.

    1979-01-01

    Flotation is used to process fly ash. In an example given, an ash containing 9% carbon is treated with an apolar collecting agent which gives a product with a calorific value of 4,000 kcal/kg, suitable for combustion in a power station. The ash content of the refuse is 98.6%.

  1. Model Predictive Control of Offshore Power Stations With Waste Heat Recovery

    DEFF Research Database (Denmark)

    Pierobon, Leonardo; Chan, Richard; Li, Xiangan;

    2016-01-01

    The implementation of waste heat recovery units on oil and gas offshore platforms demands advances in both design methods and control systems. Model-based control algorithms can play an important role in the operation of offshore power stations. A novel regulator based on a linear model predictive...

  2. [Risk of electromagnetic fields in electric power stations and substations of a petrochemical plant].

    Science.gov (United States)

    Castagnoli, A; Fabri, G; Romeo, A

    2003-01-01

    Authors evaluate electromagnetic field exposure in the low-frequency range (5-30,000 Hz) in electric power stations and substations of petroleum processing plant. According to the measured values and the reference exposure limits considered, they conclude that operators should be exposed without adverse effects.

  3. 76 FR 54502 - Energy Northwest, Columbia Generating Station; Notice of Availability of Draft Supplement 47 to...

    Science.gov (United States)

    2011-09-01

    ... COMMISSION Energy Northwest, Columbia Generating Station; Notice of Availability of Draft Supplement 47 to... Regulatory Commission (NRC) has published a draft plant-specific supplement to the Generic Environmental... renewal) include no action and reasonable alternative energy sources. Any interested party may...

  4. Next-Generation Shipboard DC Power System

    DEFF Research Database (Denmark)

    Jin, Zheming; Sulligoi, Giorgio; Cuzner, Rob

    2016-01-01

    In recent years, more and more evidence suggests that the global energy system is on the verge of a drastic revolution. The evolutionary development in power electronic technologies, the emerging high-performance energy storage devices, as well as the ever increasing penetration of renewable energy...... sources (RES) are commonly recognized as the major driven force of the revolution, the outburst of customer electronics and new kinds of household electronics is also powering this change. In this context, dc power distribution technologies have made a comeback and keep gaining a commendable increase......, aerospace/aircraft power systems, as well as maritime power systems....

  5. The features of ceramic materials structure formation when using hard-melting wastes of thermal power stations in charge stock

    Science.gov (United States)

    Skripnikova, Nelli; Yuriev, Ivan; Lutsenko, Alexander; Litvinova, Viktoriya

    2016-01-01

    The paper presents the analysis of aluminum silicate waste generated by thermal power station of the city of Seversk, Tomsk region, Russia. The chemical compositions of aluminum silicate waste are detected and the efficient mixture compositions with the addition of aluminum silicate waste are suggested herein. Ceramic brick structure formation is studied in this paper using X-ray phase and SEM analyses. It is identified that the formed vitreous phase facilitates such strengthening structural modifications as sintering out of pores and shrinkage of unmelted aluminum silicate particles with the following formation of a monolithic product.

  6. Power Generation Capabilities of Tie Tube Assemblies

    Science.gov (United States)

    Gunn, Stanley V.; Hedstrom, James; Hundal, Rolv

    1994-07-01

    Second generation nuclear thermal rocket engine designs, employing solid core reactors and expander engine cycles, generally rely on some form of nuclear-driven heater to supply the major portion of thermal energy required to preheat the turbine-drive gases. If adequate heat transfer occurs, not only will efficiency-enhancing turbine-inlet temperatures be realized, but sufficient energy will be available to enable engine operation at chamber pressures ranging to at least 2,000 psia. For the case of reactor cores employing prismatic fuel elements, the utilization of tie tube assemblies, as first employed in the core-support subsystem of the Phoebus II reactor, can provide the basis of an array of propellant (hydrogen) preheaters that offer an ample supply of energy and temperature to enable candidate expander engine cycles over a wide range of operating parameters, without reducing the total enthalpy of the core-exit gas and its attendant effect on specific impulse. By modifying the tie tube design concept set forth in LASL's Nuclear Rocket Engine definition study, a powerful, weight and packaging-effective, preheater assembly can be realized. The design features of these tie tube assemblies reflect their functional objectives, core criticality considerations, and space constraints. Since the core pressure and inertial mass loads are carried by these assemblies, the structural tubular element(s) also provide coolant passage(s) for the hydrogen. The transfer of heat to the coolant surfaces is controlled by the effective thermal conductivity of the filler structure and ``insulating sleeves,'' which surround the tubular elements and are in controlled thermal contact with the surrounding core fuel elements. An option exists to further increase the transported heat to the coolant walls by the selective loading of the filler structure, ``insulating sleeves,'' and the moderator annular element with fissionable material.

  7. The network architecture and site test of DCIS in Lungmen nuclear power station

    Energy Technology Data Exchange (ETDEWEB)

    Lee, C. K. [Instrument and Control Section, Lungmen Nuclear Power Station, Taiwan Power Company, Taipei County Taiwan (China)

    2006-07-01

    The Lungmen Nuclear Power Station (LMNPS) is located in North-Eastern Seashore of Taiwan. LMNPP has two units. Each unit generates 1350 Megawatts. It is the first ABWR Plant in Taiwan and is under-construction now. Due to contractual arrangement, there are seven large I and C suppliers/designers, which are GE NUMAC, DRS, Invensys, GEIS, Hitachi, MHI, and Stone and Webster company. The Distributed Control and Information System (DCIS) in Lungmen are fully integrated with the state-of-the-art computer and network technology. General Electric is the leading designer for integration of DCIS. This paper presents Network Architecture and the Site Test of DCIS. The network architectures are follows. GE NUMAC System adopts the point to point architecture, DRS System adopts Ring type architecture with SCRAMNET protocol, Inevnsys system adopts IGiga Byte Backbone mesh network with Rapid Spanning Tree Protocol, GEIS adopts Ethernet network with EGD protocol, Hitachi adopts ring type network with proprietary protocol. MHI adopt Ethernet network with UDP. The data-links are used for connection between different suppliers. The DCIS architecture supports the plant automation, the alarm prioritization and alarm suppression, and uniform MMI screen for entire plant. The Test Program regarding the integration of different network architectures and Initial DCIS architecture Setup for 161KV Energization will be discussed. Test tool for improving site test schedule, and lessons learned from FAT will be discussed too. And conclusions are at the end of this paper. (authors)

  8. Numerical Calculation of the Output Power of a MHD Generator

    Directory of Open Access Journals (Sweden)

    Adrian CARABINEANU

    2014-12-01

    Full Text Available Using Lazăr Dragoş’s analytic solution for the electric potential we perform some numerical calculations in order to find the characteristics of a Faraday magnetohydrodymamics (MHD power generator (total power, useful power and Joule dissipation power.

  9. Managing strategic alliances in the power generation industry

    DEFF Research Database (Denmark)

    Kumar, Rajesh

    2003-01-01

    Highlights the challenges for power development developers in initiating alliances in the power generation industry. Importance of strategic alliances in the industry; Nature of the alliances in the independent power industry; Strategies for creating and sustaining value in global power development......; Management of tensions inherent in internal and external alliances....

  10. Managing strategic alliances in the power generation industry

    DEFF Research Database (Denmark)

    Kumar, Rajesh

    2003-01-01

    Highlights the challenges for power development developers in initiating alliances in the power generation industry. Importance of strategic alliances in the industry; Nature of the alliances in the independent power industry; Strategies for creating and sustaining value in global power development......; Management of tensions inherent in internal and external alliances....

  11. Power oscillation damping by a converter-based power generation device

    DEFF Research Database (Denmark)

    2012-01-01

    There is provided a power generation park comprising a power output for providing electrical output power to an electricity network . A power generation device comprises a converter device configured for receiving input power from a power generator and providing, in response hereto, the electrical...... output power to the power output. The power generation park further comprises a controller being configured for receiving an oscillation indicating signal indicative of a power oscillation in the electricity network, the controller being further configured for providing a damping control signal...... in response to the oscillation indicating signal; the converter device being configured for modulating the electrical output power in response to the damping control signal so as to damp the power oscillation in the electricity network....

  12. Survey on the consciousness structure toward nuclear power generation

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, M.; Yoshida, T. (Nomura Research Institute, Kamakura, Kanagawa (Japan))

    1981-05-01

    A survey on the popular consciousness toward nuclear power generation was carried out by direct means of questionnaire to 1600 persons, ages from 20 to 69, in power demand areas (Tokyo and Osaka) and power supply areas (sites of nuclear power generation) from early February to early March, 1980, and the recovery rate was 74.4% (1190 persons). The results are described by way of their explanation. The purpose is to clarify the structure of popular consciousness toward nuclear energy, in particular nuclear power generation, and the nature of its acceptance. That is, it was surveyed how general people in the power supply and the power demand areas are taking nuclear power generation concerning its need and safety, and further how the attitudes are constituted and vary.

  13. Renewable energy power generation projects started construction in Tibet

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    On March 19, the construction of a 10-MW photovoltaic power plant and a 1 000-kW new type geothermal power generation project were started by Guodian Longyuan Group in Yanbajing Town, Dangxiong County of Tibet.

  14. Generating Functions for the Powers of Fibonacci Sequences

    Science.gov (United States)

    Terrana, D.; Chen, H.

    2007-01-01

    In this note, based on the Binet formulas and the power-reducing techniques, closed forms of generating functions for the powers of Fibonacci sequences are presented. The corresponding results are extended to some other famous sequences as well.

  15. STUDY ON POWER SPARE COEFFICIENT OF ELECTRICAL MOTOR IN LARGE PUMP STATION BASED ON RELIABILITY

    Institute of Scientific and Technical Information of China (English)

    Qiu Baoyun; Huang Jiyan; Yuan Shouqi

    2004-01-01

    Characters of head of low head pump station and the pump shaft power are analyzed. Influence of each single factor on pump shaft power is expressed as change of specific shaft power (non-dimensional) and the probability density function is determined. Influences of multiple factors on pump shaft power are analyzed. Method of calculating none over-loaded probability of motor by integration by successive reductions is put forward and then relation between power spare coefficient and none over-loaded reliability of electric motor is established. Influences of all factors on pump shaft power being considered completely; power spare coefficients of motor are calculated in three kinds of heads (changing and unchanging), two kinds of dirty-out conditions. Electrical motor power spare coefficients should be chosen as 1.20~1.44, 1.11~1.19, 1.09~1.14 respectively when pump heads are 4, 7, 9.5 m. The results mean much to reasonable choose of electrical motors in large pump stations, increasing reliability of pump units and saving equipment investment.

  16. Residue management and Canada's environmental codes of practice for steam electric power generation

    Energy Technology Data Exchange (ETDEWEB)

    Finlay, P.G.; Stobbs, R.A.; Ross, G.C.; Pinault, P.H.; Doiron, C.C. (Environment Canada, Ottawa, ON (Canada))

    1993-01-01

    Canada's 'Environmental Codes of Practice for Steam Electric Power Generation' are comprehensive environmental protection standards for the various phases of the life cycle of power plants. Codes published include the Siting, Design, Construction, Operation and Decommissioning Phase Codes. Various practices are recommended for the management of air emissions, water, fuels, chemicals, wastewater, and liquid and solid residues. Topics discussed include the production, utilization and disposal of residues, including combustion ashes and desulphurization by-products. An example of application of the Codes at the 'zero discharge' Shand Power Station is discussed. 6 refs., 1 fig., 1 tab.

  17. Monolithic fuel cell based power source for burst power generation

    Science.gov (United States)

    Fee, D. C.; Blackburn, P. E.; Busch, D. E.; Dees, D. W.; Dusek, J.; Easler, T. E.; Ellingson, W. A.; Flandermeyer, B. K.; Fousek, R. J.; Heiberger, J. J.

    A unique fuel cell coupled with a low power nuclear reactor presents an attractive approach for SDI burst power requirements. The monolithic fuel cell looks attractive for space applications and represents a quantum jump in fuel cell technology. Such a breakthrough in design is the enabling technology for lightweight, low volume power sources for space based pulse power systems. The monolith is unique among fuel cells in being an all solid state device. The capability for miniaturization, inherent in solid state devices, gives the low volume required for space missions. In addition, the solid oxide fuel cell technology employed in the monolith has high temperature reject heat and can be operated in either closed or open cycles. Both these features are attractive for integration into a burst power system.

  18. Grid Monitoring and Advanced Control of Distributed Power Generation Systems

    OpenAIRE

    Timbus, Adrian Vasile

    2007-01-01

    The movement towards a clean technology for energy production and the constraints in reducing the CO2 emissions are some factors facilitating the growth of distributed power generation systems based on renewable energy resources. Consequently, large penetration of distributed generators has been reported in some countries creating concerns about power system stability. This leads to a continuous evolution of grid interconnection requirements towards a better controllability of generated power...

  19. Application of Artificial Neural Networks for Predicting Generated Wind Power

    OpenAIRE

    Vijendra Singh

    2016-01-01

    This paper addresses design and development of an artificial neural network based system for prediction of wind energy produced by wind turbines. Now in the last decade, renewable energy emerged as an additional alternative source for electrical power generation. We need to assess wind power generation capacity by wind turbines because of its non-exhaustible nature. The power generation by electric wind turbines depends on the speed of wind, flow direction, fluctuations, density of air, gener...

  20. Complex use of waste in wastewater and circulating water treatment from oil in heat power stations

    Science.gov (United States)

    Nikolaeva, L. A.; Iskhakova, R. Ya.

    2017-06-01

    Sewage and circulating water from oil of thermal power plants (TPP) generated in fuel-oil shops during washing of electrical equipment and its running into the storm drainage system from the industrial site has been considered in the paper. It has been suggested to use the carbonate sludge of water treatment modified with hydrophobing emulsion as a sorption material for waste and circulating water treatment in thermal power plants. The carbonate sludge is waste accumulated in clarifiers at the stage of natural water pretreatment. General technical characteristics of the sludge, such as moisture, bulk density, total pore volume, ash, etc., have been determined. It has been found that the sludge without additional treatment is a hydrophilic material that has low adsorption capacity and wettability with nonpolar compounds. Therefore, the sludge is treated with organosilicon compounds to reduce the moisture capacity and increase its floatation. Several types of sorption materials based on the carbonate sludge subjected to surface and volume hydrophobization have been developed. During the volume treatment, the hydrophobing compound has been introduced into the material along with the plastifier. In case of the surface treatment, heat-treated granules have been soaked into hydrophobing emulsion. It has been shown that surface hydrophobization is most economically advantageous, because it reduces the consumption of water-repelling agent, wherein the total pore volume and sorption capacity during surface hydrophobization increase by 45 and 25% compared to that during volume hydrophobization. Based on the obtained results, the most effective sorption material has been chosen. To produce this material, it is necessary to sequentially carry out mixing of carbonate sludge with the binder, granulation, calcination, impregnation with a waterrepellent emulsion, and drying of the finished material. The suggested technology to produce the material and use it as a sorbent allows

  1. Implicit attitudes toward nuclear power and mobile phone base stations: support for the affect heuristic.

    Science.gov (United States)

    Siegrist, Michael; Keller, Carmen; Cousin, Marie-Eve

    2006-08-01

    The implicit association test (IAT) measures automatic associations. In the present research, the IAT was adapted to measure implicit attitudes toward technological hazards. In Study 1, implicit and explicit attitudes toward nuclear power were examined. Implicit measures (i.e., the IAT) revealed negative attitudes toward nuclear power that were not detected by explicit measures (i.e., a questionnaire). In Study 2, implicit attitudes toward EMF (electro-magnetic field) hazards were examined. Results showed that cell phone base stations and power lines are judged to be similarly risky and, further, that base stations are more closely related to risk concepts than home appliances are. No differences between experts and lay people were observed. Results of the present studies are in line with the affect heuristic proposed by Slovic and colleagues. Affect seems to be an important factor in risk perception.

  2. Implications of climate change on the heat budget of lentic systems used for power station cooling: Case study Clinton Lake, Illinois

    Science.gov (United States)

    Quijano, Juan C; Jackson, P. Ryan; Santacruz, Santiago; Morales, Viviana M; Garcia, Marcelo H.

    2016-01-01

    We use a numerical model to analyze the impact of climate change--in particular higher air temperatures--on a nuclear power station that recirculates the water from a reservoir for cooling. The model solves the hydrodynamics, the transfer of heat in the reservoir, and the energy balance at the surface. We use the numerical model to (i) quantify the heat budget in the reservoir and determine how this budget is affected by the combined effect of the power station and climate change and (ii) quantify the impact of climate change on both the downstream thermal pollution and the power station capacity. We consider four different scenarios of climate change. Results of simulations show that climate change will reduce the ability to dissipate heat to the atmosphere and therefore the cooling capacity of the reservoir. We observed an increase of 25% in the thermal load downstream of the reservoir, and a reduction in the capacity of the power station of 18% during the summer months for the worst-case climate change scenario tested. These results suggest that climate change is an important threat for both the downstream thermal pollution and the generation of electricity by power stations that use lentic systems for cooling.

  3. Implications of Climate Change on the Heat Budget of Lentic Systems Used for Power Station Cooling: Case Study Clinton Lake, Illinois.

    Science.gov (United States)

    Quijano, Juan C; Jackson, P Ryan; Santacruz, Santiago; Morales, Viviana M; García, Marcelo H

    2016-01-05

    We use a numerical model to analyze the impact of climate change-in particular higher air temperatures-on a nuclear power station that recirculates the water from a reservoir for cooling. The model solves the hydrodynamics, the transfer of heat in the reservoir, and the energy balance at the surface. We use the numerical model to (i) quantify the heat budget in the reservoir and determine how this budget is affected by the combined effect of the power station and climate change and (ii) quantify the impact of climate change on both the downstream thermal pollution and the power station capacity. We consider four different scenarios of climate change. Results of simulations show that climate change will reduce the ability to dissipate heat to the atmosphere and therefore the cooling capacity of the reservoir. We observed an increase of 25% in the thermal load downstream of the reservoir, and a reduction in the capacity of the power station of 18% during the summer months for the worst-case climate change scenario tested. These results suggest that climate change is an important threat for both the downstream thermal pollution and the generation of electricity by power stations that use lentic systems for cooling.

  4. Allowable Residual Contamination Levels in soil for decommissioning the Shippingport Atomic Power Station site

    Energy Technology Data Exchange (ETDEWEB)

    Kennedy, W.E. Jr.; Napier, B.A.; Soldat, J.K.

    1983-09-01

    As part of decommissioning the Shippingport Atomic Power Station, a fundamental concern is the determination of Allowable Residual Contamination Levels (ARCL) for radionuclides in the soil at the site. The ARCL method described in this report is based on a scenario/exposure-pathway analysis and compliance with an annual dose limit for unrestricted use of the land after decommissioning. In addition to naturally occurring radionuclides and fallout from weapons testing, soil contamination could potentially come from five other sources. These include operation of the Shippingport Station as a pressurized water reactor, operations of the Shippingport Station as a light-water breeder, operation of the nearby Beaver Valley reactors, releases during decommissioning, and operation of other nearby industries, including the Bruce-Mansfield coal-fired power plants. ARCL values are presented for 29 individual radionculides and a worksheet is provided so that ARCL values can be determined for any mixture of the individual radionuclides for any annual dose limit selected. In addition, a worksheet is provided for calculating present time soil concentration value that will decay to the ARCL values after any selected period of time, such as would occur during a period of restricted access. The ARCL results are presented for both unconfined (surface) and confined (subsurface) soil contamination. The ARCL method and results described in this report provide a flexible means of determining unrestricted-use site release conditions after decommissioning the Shippingport Atomic Power Station.

  5. The effects of solar-geomagnetically induced currents on electrical systems in nuclear power stations

    Energy Technology Data Exchange (ETDEWEB)

    Subudhi, M. [Brookhaven National Lab., Upton, NY (United States); Carroll, D.P. [Florida Univ., Gainesville, FL (United States); Kasturi, S. [MOS, Inc., Melville, NY (United States)

    1994-01-01

    This report presents the results of a study to evaluate the potential effects of geomagnetically induced currents (GICs) caused by the solar disturbances on the in-plant electrical distribution system and equipment in nuclear power stations. The plant-specific electrical distribution system for a typical nuclear plant is modeled using the ElectroMagnetic Transient Program (EMTP). The computer model simulates online equipment and loads from the station transformer in the switchyard of the power station to the safety-buses at 120 volts to which all electronic devices are connected for plant monitoring. The analytical model of the plant`s electrical distribution system is studied to identify the transient effects caused by the half-cycle saturation of the station transformers due to GIC. This study provides results of the voltage harmonics levels that have been noted at various electrical buses inside the plant. The emergency circuits appear to be more susceptible to high harmonics due to the normally light load conditions. In addition to steady-state analysis, this model was further analyzed simulating various plant transient conditions (e.g., loss of load or large motor start-up) occurring during GIC events. Detail models of the plant`s protective relaying system employed in bus transfer application were included in this model to study the effects of the harmonic distortion of the voltage input. Potential harmonic effects on the uniterruptable power system (UPS) are qualitatively discussed as well.

  6. Project risk control of underground engineering geological disaster in pumped-storage power station

    Institute of Scientific and Technical Information of China (English)

    Luo Shaoji

    2014-01-01

    This paper introduced the construction of the pumped-storage power station (PSPS). In the excava- tion of underground power house, the principle of excavation in thin layer and support in time with real time monitoring are adopted. The excavation blasting parameters are adjusted timely. Through these, the excavation quality can be guaranteed, the surrounding rock can be prevented from being damaged and the deformation of power house side wall can be controlled. Five security defense lines have been adopted to solve anti-seepage and drainage in the major underground projects.

  7. Project risk control of underground engineering geological disaster in pumped-storage power station

    Institute of Scientific and Technical Information of China (English)

    Luo Shaoji

    2014-01-01

    This paper introduced the construction of the pumped-storage power station (PSPS). In the excava-tion of underground power house,the principle of excavation in thin layer and support in time with real time monitoring are adopted. The excavation blasting parameters are adjusted timely. Through these,the excavation quality can be guaranteed,the surrounding rock can be prevented from being damaged and the deformation of power house side wall can be controlled. Five security defense lines have been adopted to solve anti-seepage and drainage in the major underground projects.

  8. The European fossil-fuelled power station database used in the SEI CASM model

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, P. [comp.] [Stockholm Environment Inst. at York (United Kingdom)

    1996-06-01

    The database contains details of power stations in Europe that burn fossil-fuels. All countries are covered from Ireland to the European region of Russia as far as the Urals. The following data are given for each station: Location (country and EMEP square), capacity (net MW{sub e} and boiler size), year of commissioning, and fuels burnt. A listing of the database is included in the report. The database is primarily used for estimation of emissions and abatement costs of sulfur and nitrogen oxides in the SEI acid rain model CASM. 24 refs, tabs

  9. A novel static frequency converter based on multilevel cascaded H-bridge used for the startup of synchronous motor in pumped-storage power station

    Energy Technology Data Exchange (ETDEWEB)

    Wang Feng, E-mail: sjtuwfeng@hotmail.co [Key Lab of Control of Power Transmission and Transformation, Ministry of Education, Department of Electrical Engineering, Shanghai Jiaotong University, Minhang District, Shanghai 200240 (China); Jiang Jianguo, E-mail: jiang@sjtu.edu.c [Key Lab of Control of Power Transmission and Transformation, Ministry of Education, Department of Electrical Engineering, Shanghai Jiaotong University, Minhang District, Shanghai 200240 (China)

    2011-05-15

    Research highlights: {yields} A novel Static Frequency Converter (SFC) based on multilevel cascaded H-bridge (CHB) topology is proposed and used for the reversible pump-generating units in pumped-storage power station. {yields} The novel SFC based on CHB has compact configuration, low current harmonic distortion and fast speed response. {yields} Rotor position and Grid connection are realized successfully by the novel SFC. -- Abstract: A novel static frequency converter (SFC) is proposed and is used firstly to start the reversible pump-generating units in pumped-storage power station. Multilevel cascaded H-bridge (CHB) topology and Insulated Gate Bipolar Transistor (IGBT) are applied in the novel SFC. In comparison with the conventional SFC adopting load-commutated inverter (LCI) which is composed of silicon-controlled rectifier (SCR), the novel one has plenty of advantages such as compact configuration, low current harmonic distortion and fast speed response, and these advantages have been verified during 2-year operation at Xiang Hong Dian Pumped-storage power station in China. This application shows that the novel SFC greatly enhances the reliability and success rate of connecting to grid for starting up the pump-generating units. The principle, characteristic and performance of the novel SFC are described in this paper, and some key issues related to the startup of the units of the pumped-storage power station are also presented.

  10. Imaging and power generation strategies for Chandrayaan-1

    Indian Academy of Sciences (India)

    Ananth Krishna; N S Gopinath; N S Hegde; N K Malik

    2005-12-01

    The Chandrayaan-1 mission proposes to put a 550 kg lunarcraft into Geostationary Transfer Orbit (GTO)using the Polar Satellite Launch Vehicle (PSLV)which will subsequently be transferred into a 100 km circular lunar polar orbit for imaging purposes.In this paper,we describe certain aspects of mission strategies which will allow optimum power generation and imaging of the lunar surface. The lunar orbit considered is circular and polar and therefore nearly perpendicular to the ecliptic plane.Unlike an Earth orbiting remote sensing satellite,the orbit plane of lunar orbiter is inertially fixed as a consequence of the very small oblateness of the Moon.The Earth rotates around the Sun once a year,resulting in an apparent motion of Sun around this orbit in a year.Two extreme situations can be identified concerning the solar illumination of the lunar orbit,noon/midnight orbit,where the Sun vector is parallel to the spacecraft orbit plane and dawn/dusk orbit,where the Sun vector is perpendicular to the spacecraft orbit plane.This scenario directly affects the solar panel configuration.In case the solar panels are not canted,during the noon/midnight orbit, 100%power is generated,whereas during the dawn/dusk orbit,zero power is generated.Hence for optimum power generation,canting of the panels is essential.Detailed analysis was carriedout to fix optimum canting and also determine a strategy to maintain optimum power generation throughout the year.The analysis led to the strategy of 180° yaw rotation at noon/midnight orbits and flipping the solar panel by 180° at dawn/dusk orbits.This also resulted in the negative pitch face of the lunarcraft to be an anti-sun panel,which is very useful for thermal design,and further to meet cooling requirements of the spectrometers. In principle the Moon ’s surface can be imaged in 28 days,because the orbit chosen and the payload swath provide adequate overlap.However,in reality it is not possible to complete the imaging in 28 days

  11. Circuit Simulation of Light Ⅱ-A Pulsed Power Generator

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    <正>The Light Ⅱ-A pulsed power generator could be divided into the following parts, a Marx generator consisting of 12 spark gap switches and 24 low inductance capacitors (Maxwell Corporation products)

  12. 18 CFR 801.12 - Electric power generation.

    Science.gov (United States)

    2010-04-01

    ... basin for additional hydroelectric generation, and considerable potential for additional pumped storage... of the waters of the basin for the generation of electric power at hydro, pumped storage, and...

  13. Proceedings of scientific-technical seminar: materials investigation for power stations and power grid; Seminarium naukowo-techniczne: Badania materialowe na potrzeby elektrowni i sieci elektroenergetycznych

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-05-01

    This report is an assembly of the papers concerning the material problems occurring during the exploitation of power stations as well as power grid. The diagnostic methods are also discussed. (author).

  14. 47 CFR 73.6012 - Protection of Class A TV, low power TV and TV translator stations.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Protection of Class A TV, low power TV and TV... of Class A TV, low power TV and TV translator stations. An application to change the facilities of an existing Class A TV station will not be accepted if it fails to protect other authorized Class A TV,...

  15. A Maximum Power Tracker for Improved Thermophotovoltaic Power Generation Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Radioisotope Power Systems (RPS) are critical for future flagship exploration missions in space and on planetary surfaces. Small improvements in the RPS performance,...

  16. 76 FR 23846 - Virginia Electric Power Company, LLC, North Anna Power Station, Unit No. 1; Exemption

    Science.gov (United States)

    2011-04-28

    ... licensee described elements of their fire protection program that provide their justification that the... source is effectively eliminated. In addition, guidance in the ``Station Lubrication Manual'' outlines... Lubrication Manual is procedurally controlled and requires authorization to be changed. With the exception...

  17. Synchrophasor Applications for Wind Power Generation

    Energy Technology Data Exchange (ETDEWEB)

    Muljadi, E.; Zhang, Y. C.; Allen, A.; Singh, M.; Gevorgian, V.; Wan, Y. H.

    2014-02-01

    The U.S. power industry is undertaking several initiatives that will improve the operations of the electric power grid. One of those is the implementation of wide-area measurements using phasor measurement units to dynamically monitor the operations and status of the network and provide advanced situational awareness and stability assessment. The overviews of synchrophasors and stability analyses in this report are intended to present the potential future applications of synchrophasors for power system operations under high penetrations of wind and other renewable energy sources.

  18. SOARCA Peach Bottom Atomic Power Station Long-Term Station Blackout Uncertainty Analysis: Convergence of the Uncertainty Results

    Energy Technology Data Exchange (ETDEWEB)

    Bixler, Nathan E.; Osborn, Douglas.; Sallaberry, Cedric Jean-Marie; Eckert-Gallup, Aubrey Celia; Mattie, Patrick D.; Ghosh, S. Tina

    2014-02-01

    This paper describes the convergence of MELCOR Accident Consequence Code System, Version 2 (MACCS2) probabilistic results of offsite consequences for the uncertainty analysis of the State-of-the-Art Reactor Consequence Analyses (SOARCA) unmitigated long-term station blackout scenario at the Peach Bottom Atomic Power Station. The consequence metrics evaluated are individual latent-cancer fatality (LCF) risk and individual early fatality risk. Consequence results are presented as conditional risk (i.e., assuming the accident occurs, risk per event) to individuals of the public as a result of the accident. In order to verify convergence for this uncertainty analysis, as recommended by the Nuclear Regulatory Commission’s Advisory Committee on Reactor Safeguards, a ‘high’ source term from the original population of Monte Carlo runs has been selected to be used for: (1) a study of the distribution of consequence results stemming solely from epistemic uncertainty in the MACCS2 parameters (i.e., separating the effect from the source term uncertainty), and (2) a comparison between Simple Random Sampling (SRS) and Latin Hypercube Sampling (LHS) in order to validate the original results obtained with LHS. Three replicates (each using a different random seed) of size 1,000 each using LHS and another set of three replicates of size 1,000 using SRS are analyzed. The results show that the LCF risk results are well converged with either LHS or SRS sampling. The early fatality risk results are less well converged at radial distances beyond 2 miles, and this is expected due to the sparse data (predominance of “zero” results).

  19. Provision of Continuity in Power Supply of Wind Power Stations by Improvement of Methods for Control of Oil Transformer Serviceability

    Directory of Open Access Journals (Sweden)

    Y. A. Rolik

    2010-01-01

    Full Text Available The paper considers problems pertaining to reduction of time for restoration of a wind power station (WPS by development of a method and control means according to informative parameter. A high-voltage oil transformer has been selected as a control WPS object.  The paper shows that the most informative parameter determining continuity in WPS power supply is an over-heating temperature of oil transformer elements. A method and means for control of WPS oil transformer serviceability are proposed in the paper.

  20. Nanostructured electrodes for Solar Power Generation Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The key to achieving high-power solar arrays for NASA applications is the development of high-efficiency, thin-film solar cells that can be fabricated directly on...

  1. Coal gasification for electric power generation.

    Science.gov (United States)

    Spencer, D F; Gluckman, M J; Alpert, S B

    1982-03-26

    The electric utility industry is being severely affected by rapidly escalating gas and oil prices, restrictive environmental and licensing regulations, and an extremely tight money market. Integrated coal gasification combined cycle (IGCC) power plants have the potential to be economically competitive with present commercial coal-fired power plants while satisfying stringent emission control requirements. The current status of gasification technology is discussed and the critical importance of the 100-megawatt Cool Water IGCC demonstration program is emphasized.

  2. Sub-atmospheric disk generators for coal-fired MHD/steam combined cycle power plant

    Energy Technology Data Exchange (ETDEWEB)

    Messerle, H.K.; Fang, Y.; Simpson, S.W.; Marty, S.M. (Sydney Univ. (Australia). School of Electrical Engineering)

    1989-01-01

    A coal fired MHD disk generator in a combined cycle MHD/steam power generation system with a diffuser operating at sub-atmospheric pressure is proposed. The effects of pressure on the performance of a radial outflow MHD disk generator and other system components are analysed. Using a previous study as a reference case, preliminary calculations show that, in such a sub-atmospheric system, improved power station efficiency can be achieved. In addition, operation at reduced values of magnetic field strength would be feasible. Calculations have also been carried out for a 30 MW{sub th} experimental disk generator operating at reduced pressure with a magnetic field strength of 2 T. Flow conditions at sub-atmospheric pressure would provide an improved simulation of a full-scale generator operating at normal pressures. (author).

  3. Numerical analysis of transient pressure variation in the condenser of a nuclear power station

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xinjun; Zhou, Zijie; Song, Zhao [Xi' an Jiaotong University, Xi' an (China); Lu, Qiankui; Li, Jiafu [Dong Fang Turbine Co., Ltd, Deyang (China)

    2016-02-15

    To research the characteristics of the transient variation of pressure in a nuclear power station condenser under accident condition, a mathematical model was established which simulated the cycling cooling water, heat transfer and pressure in the condenser. The calculation program of transient variation characteristics was established in Fortran language. The pump's parameter, cooling line's organization, check valve's feature and the parameter of siphonic water-collecting well are involved in the cooling water flow's mathematical model. The initial conditions of control volume are determined by the steady state of the condenser. The transient characteristics of a 1000 MW nuclear power station's condenser and cooling water system were examined. The results show that at the condition of plant-power suspension of pump, the cooling water flow rate decreases rapidly and refluxes, then fluctuates to 0. The variation of heat transfer coefficient in the condenser has three stages: at start it decreases sharply, then increases and decreases, and keeps constant in the end. Under three conditions (design, water and summer), the condenser pressure goes up in fluctuation. The time intervals between condenser's pressure signals under three conditions are about 26.4 s, which can fulfill the requirement for safe operation of nuclear power station.

  4. Modeling of a Photovoltaic-Powered Electric Vehicle Charging Station with Vehicle-to-Grid Implementation

    Directory of Open Access Journals (Sweden)

    Azhar Ul-Haq

    2016-12-01

    Full Text Available This paper is aimed at modelling of a distinct smart charging station for electric vehicles (EVs that is suitable for DC quick EV charging while ensuring minimum stress on the power grid. Operation of the charging station is managed in such a way that it is either supplied by photovoltaic (PV power or the power grid, and the vehicle-to-grid (V2G is also implemented for improving the stability of the grid during peak load hours. The PV interfaced DC/DC converter and grid interfaced DC/AC bidirectional converter share a DC bus. A smooth transition of one operating mode to another demonstrates the effectiveness of the employed control strategy. Modelling and control of the different components are explained and are implemented in Simulink. Simulations illustrate the feasible behaviour of the charging station under all operating modes in terms of the four-way interaction among PV, EVs and the grid along with V2G operation. Additionally, a business model is discussed with comprehensive analysis of cost estimation for the deployment of charging facilities in a residential area. It has been recognized that EVs bring new opportunities in terms of providing regulation services and consumption flexibility by varying the recharging power at a certain time instant. The paper also discusses the potential financial incentives required to inspire EV owners for active participation in the demand response mechanism.

  5. Study of Low Voltage Ride Through Performance for Wind Power Generation with Doubly Fed Induction Generator

    Science.gov (United States)

    Hirawata, Ryoya; Kai, Takaaki

    Recently, the introduction of wind power generation is increasing rapidly. The ratio of wind power generation to the capacity of a total generation is getting higher and higher. When the phase-to-phase fault occurs in the power system, the frequency of power system is lower due to disconnecting of the wind power generation with doubly fed induction generator (DFIG). Therefore, the power system might become unstable. This paper describes the LVRT (low voltage ride through) performance improvement scheme of the wind power generation with DFIG. The wind power generation is disconnected from the grid in case of the power system fault. It is independently in operation from the grid by controlling of the inverter equipped in the generation. After clearance of the power system fault, the wind power generation is immediately re-connected to the grid. As a result, instability in the power system disappears. The performance of LVRT is confirmed by using simulation software PSCAD/EMTDC. The simulation result shows an excellent result to the three-phase short-circuit fault of the voltage dip 100%.

  6. 33 CFR 165.552 - Security Zone; Oyster Creek Generation Station, Forked River, Ocean County, New Jersey.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Security Zone; Oyster Creek... Coast Guard District § 165.552 Security Zone; Oyster Creek Generation Station, Forked River, Ocean... the Forked River in the vicinity of the Oyster Creek Generation Station, bounded by a line...

  7. Intelligent Power Management of hybrid Wind/ Fuel Cell/ Energy Storage Power Generation System

    Directory of Open Access Journals (Sweden)

    A. Hajizadeh

    2013-12-01

    Full Text Available This paper presents an intelligent power management strategy for hybrid wind/ fuel cell/ energy storage power generation system. The dynamic models of wind turbine, fuel cell and energy storage have been used for simulation of hybrid power system. In order to design power flow control strategy, a fuzzy logic control has been implemented to manage the power between power sources. The optimal operation of the hybrid power system is a main goal of designing power management strategy. The hybrid power system is simulated in MATLAB/ SIMIULINK environment and different operating conditions have been considered to evaluate the response of power management strategy.

  8. Refurbishment Status of Light Ⅱ-A Pulsed Power Generator

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    <正>The Light Ⅱ-A pulsed power generator, formerly used to pump KrF laser, was updated around the year 2000 from the original Light Ⅱ, a pulsed power generator built in 1980s at CIAE. This machine was

  9. Windfarm generation assessment for reliability analysis of power systems

    DEFF Research Database (Denmark)

    Negra, N.B.; Holmstrøm, O.; Bak-Jensen, B.;

    2007-01-01

    Due to the fast development of wind generation in the past ten years, increasing interest has been paid to techniques for assessing different aspects of power systems with a large amount of installed wind generation. One of these aspects concerns power system reliability. Windfarm modelling plays...

  10. Fiber optical magnetic field sensor for power generator monitoring

    Science.gov (United States)

    Willsch, Michael; Bosselmann, Thomas; Villnow, Michael

    2014-05-01

    Inside of large electrical engines such as power generators and large drives, extreme electric and magnetic fields can occur which cannot be measured electrically. Novel fiber optical magnetic field sensors are being used to characterize the fields and recognize inner faults of large power generators.

  11. Measurement of the magnetic properties of P9 and T22 steel taken from service in power station

    Science.gov (United States)

    Wilson, J. W.; Karimian, N.; Liu, J.; Yin, W.; Davis, C. L.; Peyton, A. J.

    2014-06-01

    With the UK's aging power generation network, life-extension of steel plant components is a critical issue. However, in order to evaluate the likelihood of component failure, techniques must be developed to properly assess the level of degradation in power station steels. Electromagnetic inspection has the potential to quantify the level of degradation through in-situ measurements at elevated temperatures. This paper reports the results of tests carried out on thermally treated P9 and T22 steel samples with different microstructural states using major and minor B-H loop measurements and magnetic Barkhausen noise measurements. The results show that by careful selection of minor loop parameters, specific to the material under inspection and the material change under consideration, correlations can established between EM properties and material properties such as Vickers hardness. These results will be used as a basis for the further development of a fully field deployable device.

  12. A Vector Control for Grid-connected Wind Power Generation with Doubly Fed Induction Generator

    Science.gov (United States)

    Kai, Takaaki; Tanaka, Yuji; Kaneda, Hirotoshi; Kobayashi, Daichi; Tanaka, Akio

    Recently, doubly fed induction generator (DFIG) and synchronous generator are mostly applied for wind power generation due to high efficiently for wind energy capture. An inverter system is required to control wind turbine speed and power factor in those generators. The inverter rating of the synchronous generator equals to generator rating. However, DFIG has the advantage that the inverter rating is about 25% to the generator rating. The paper describes a vector control of DFIG inter-connected to power line. The performance of proposed vector control is examined using power system simulation software PSCAD/EMTDC for the DFIG inter-connected to 6.6kv distribution line. The results show good dynamic responses and high accuracy to the stator active power control and the stator reactive power control.

  13. Novel Power Conditioning Circuits for Piezoelectric Micro Power Generators

    Science.gov (United States)

    2003-10-31

    Voltage Multiplier Circuits,” IEEE Trans. on Circuits and Systems, vol. CAS-24, No. 10, Oct. 1977, pp. 517-530. [38] A. S. Sedra , and K. C. Smith ...Proceedings, PowerCon 2000, International Conference on, vol.3, Dec. 2000, pp.1605 – 1608. [3] V. J. Gosbell, V. Smith , D. A. Robinson, B.S.P. Perera

  14. Gas-fired Power Generation in India: Challenges and opportunities

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-07-01

    India's fast growing economy needs to add 100,000 MW power generating capacity between 2002-2012. Given limitations to the use of coal in terms of environmental considerations, quality and supply constraints, gas is expected to play an increasingly important role in India's power sector. This report briefs NMC Delegates on the potential for gas-fired power generation in India and describes the challenges India faces to translate the potential for gas-fired power generation into reality.

  15. Gas-fired Power Generation in India: Challenges and opportunities

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-07-01

    India's fast growing economy needs to add 100,000 MW power generating capacity between 2002-2012. Given limitations to the use of coal in terms of environmental considerations, quality and supply constraints, gas is expected to play an increasingly important role in India's power sector. This report briefs NMC Delegates on the potential for gas-fired power generation in India and describes the challenges India faces to translate the potential for gas-fired power generation into reality.

  16. Distributed Power-Generation Systems and Protection

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Yang, Yongheng; Yang, Dongsheng

    2017-01-01

    penetration degree of renewable energy, among which wind and solar photovoltaics are typical sources. The integration level of the DPGS into the grid plays a critical role in developing sustainable and resilient power systems, especially with highly intermittent renewable energy resources. To address...... for the DPGS to consolidate the integration. In light of the above, this paper reviews the power-conversion and control technologies used for DPGSs. The impacts of the DPGS on the distributed grid are also examined, and more importantly, strategies for enhancing the connection and protection of the DPGS...

  17. Application of Artificial Neural Networks for Predicting Generated Wind Power

    Directory of Open Access Journals (Sweden)

    Vijendra Singh

    2016-03-01

    Full Text Available This paper addresses design and development of an artificial neural network based system for prediction of wind energy produced by wind turbines. Now in the last decade, renewable energy emerged as an additional alternative source for electrical power generation. We need to assess wind power generation capacity by wind turbines because of its non-exhaustible nature. The power generation by electric wind turbines depends on the speed of wind, flow direction, fluctuations, density of air, generator hours, seasons of an area, and wind turbine position. During a particular season, wind power generation access can be increased. In such a case, wind energy generation prediction is crucial for transmission of generated wind energy to a power grid system. It is advisable for the wind power generation industry to predict wind power capacity to diagnose it. The present paper proposes an effort to apply artificial neural network technique for measurement of the wind energy generation capacity by wind farms in Harshnath, Sikar, Rajasthan, India.

  18. Thermal-hydraulic tests of a recirculation cooling installation for the Rostov nuclear power station

    Science.gov (United States)

    Balunov, B. F.; Balashov, V. A.; Il'in, V. A.; Krayushnikov, V. V.; Lychakov, V. D.; Meshalkin, V. V.; Ustinov, A. N.; Shcheglov, A. A.

    2013-09-01

    Results obtained from thermal-hydraulic tests of the recirculation cooling installation used as part of the air cooling system under the containments of the Rostov nuclear power station Units 3 and 4 are presented. The operating modes of the installation during normal operation (air cooling on the surface of finned tubes), under the conditions of anticipated operational occurrences (air cooling and steam condensation from a steam-air mixture), and during an accident (condensation of pure steam) are considered. Agreement is obtained between the results of tests and calculations carried out according to the recommendations given in the relevant regulatory documents. A procedure of carrying out thermal calculation for the case of steam condensation from a steam-air mixture on the surface of fins is proposed. The possibility of efficient use of the recirculation cooling installation in the system for reducing emergency pressure under the containment of a nuclear power station is demonstrated.

  19. Solar-assisted MED treatment of Eskom power station waste water

    Science.gov (United States)

    Roos, Thomas H.; Rogers, David E. C.; Gericke, Gerhard

    2017-06-01

    The comparative benefits of multi-effect distillation (MED) used in conjunction with Nano Filtration (NF), Reverse Osmosis (RO) and Eutectic Freeze Crystallization (EFC) are determined for waste water minimization for inland coal fired power stations for Zero Liquid Effluent Discharge (ZLED). A sequence of technologies is proposed to achieve maximal water recovery and brine concentration: NF - physico-chemical treatment - MED - EFC. The possibility of extending the concentration of RO reject arising from minewater treatment at the Lethabo power station with MED alone is evaluated with mineral formation modelling using the thermochemical modelling software Phreeq-C. It is shown that pretreatment is essential to extend the amount of water that can be recovered, and this can be beneficially supported by NF.

  20. Magnetic sensing for microstructural assessment of power station steels: Differential permeability and magnetic hysteresis

    Science.gov (United States)

    Karimian, N.; Wilson, J. W.; Yin, W.; Liu, J.; Davis, C. L.; Peyton, A. J.

    2013-06-01

    Failure of power station steel components can have severe economic impacts and also present significant risks to life and the environment. Currently components are inspected during costly shut-downs as no in-situ technique exists to monitor changes in microstructure of in-service steel components. Electromagnetic inspection has the potential to provide information on microstructure changes in power station steels in-situ. In this paper, tests have been carried out on pipe and tube samples in different microstructural conditions, using a lab-based closed magnetic circuit and impedance measurement systems. EM properties have been identified with correlations to material properties, which can quantify degradation in-situ and at elevated temperatures.

  1. Cooling tower restoration in the joint nuclear power station Neckar 1; Kuehlturmsanierung im Gemeinschaftskernkraftwerk Neckar 1

    Energy Technology Data Exchange (ETDEWEB)

    Ernst, G. [Karlsruhe Univ. (T.H.) (Germany). Inst. fuer Technische Thermodynamik; Braeuning, G. [Karlsruhe Univ. (T.H.) (Germany). Inst. fuer Technische Thermodynamik; Dekker, G. [Marley Kuehlturm GmbH, Duesseldorf (Germany). Bereich Vertrieb neuer Kuhlturm-Anlagen

    1996-11-01

    Since the starting operation of the Power Station GKN I (Joint Nuclear Power Station Neckar I) in the year 1976, the cell cooler of the plant was, except for those cases in which continuous-flow cooling was possible, continually in operation. Aim of the restoration, after an operational time of 17 years, is a further constructional and thermal service life of about 15 to 20 years. (orig.) [Deutsch] Seit der Inbetriebnahme des Kraftwerkes GKN I im Jahr 1976 war der Zellenkuehler der Anlage bis auf die Faelle, in denen Durchlaufkuehlung moeglich war, ununterbrochen in Betrieb. Ziel der Sanierung nach ueber 17jaehriger Betriebszeit ist eine weitere bauliche und thermische Nutzungsdauer von etwa 15 bis 20 Jahren. (orig.)

  2. Combined Base Station Association and Power Control in Multi-channel Cellular Networks

    CERN Document Server

    Singh, Chandramani; Sundaresan, Rajesh

    2011-01-01

    A combined base station association and power control problem is studied for the uplink of multichannel multicell cellular networks, in which each channel is used by exactly one cell (i.e., base station). A distributed association and power update algorithm is proposed and shown to converge to a Nash equilibrium of a noncooperative game. We consider network models with discrete mobiles (yielding an atomic congestion game), as well as a continuum of mobiles (yielding a population game). We find that the equilibria need not be Pareto efficient, nor need they be system optimal. To address the lack of system optimality, we propose pricing mechanisms. It is shown that these mechanisms can be implemented in a distributed fashion.

  3. Functions and concept of the process information system for a power station

    Energy Technology Data Exchange (ETDEWEB)

    Woyke, W. [E.ON Energie AG, Neue Technologien, Muenchen (Germany). Regenerative Energieumwandlung

    2001-07-01

    Methods of archiving, evaluation and compression in connection with measured values of the process information system is a link between control system and office application. The applications and tasks, functions and concept of the process information system of a power station will be explained. Practical examples of the introduction of the process information system for a power station of E.ON Kraftwerke GmbH, real applications in the field of process optimization, process analysis and reporting will demonstrate the system. (orig.) [German] Durch Archivierung, Auswertung und Komprimierung von Messwerten schafft das Prozessinformationssystem ein Bindeglied zwischen Leittechnik auf der einen und Office-Anwendungen auf der anderen Seite, Ausgehend von Anwendungen und Aufgaben werden Funktionen und Konzept fuer das Prozessinformationssystem in einem Kraftwerk dargestellt. Anhand von praktischen Beispielen aus der Einfuehrung eines Prozessinformationssystems in einem Kraftwerk der E.ON Kraftwerke GmbH werden konkrete Anwendungen aus dem Bereich von Prozessoptimierung, Prozessanalyse und Berichtswesen mit einem Prozessinformationssystem erlaeutert. (orig.)

  4. Steam generators, industrial power plants, and cogeneration plants. Lectures; Dampferzeuger, Industrie- und Heizkraftwerke 2010. Vortraege

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    The proceedings of the meeting on steam generators, industrial power plants, and cogeneration plants include the following lectures: Assignments and scopes of the VGB working group ''industry and thermal power plants, BHKW''. Combustion power and process control - application of feed grate firing in industrial technology - experiences and perspectives. A new possibility of biomass co-combustion. Biomass co-combustion in Vattenfall Waerme AG. Biomass plant with optimized control. The new energy supply concept for the paper plant in Plattling. Efficient steam boiler facilities for industry and thermal power plants - case studies. Adaptation of flue gas purification for co-combustion with experiences of prototype plants. Modern risk and insurance management for power plants. Reliability oriented maintenance. Surrogate fuel IHKW Gersthofen - planning, construction and preliminary operational experiences. Assignments and scopes of the VGB working group ''steam generators''. New developments in process safety management of E.ON UK coal-fired power plants. Station-supply reduction by power drive reconstruction to frequency control - modern injection technology at high plant parameters. Self-optimizing control of fuel/air regulation. CO{sub 2} reduction by automatic power plant modeling. Virtual reality as QA tool in 3D planning. Thermodynamic studies in power plants using VDI 2048. Heating surface cleaning with explosion generators - an alternative to soot blowers. results of laboratory study on urgent material questions.

  5. Compensation for Harmonic Currents and Reactive Power in Wind Power Generation System using PWM Inverter

    Science.gov (United States)

    Shinohara, Katsuji; Shinhatsubo, Kurato; Iimori, Kenichi; Yamamoto, Kichiro; Saruban, Takamichi; Yamaemori, Takahiro

    In recent year, consciousness of environmental problems is enhancing, and the price of the electric power purchased by an electric power company is established expensive for the power plant utilizing the natural energy. So, the introduction of the wind power generation is promoted in Japan. Generally, squirrel-cage induction machines are widely used as a generator in wind power generation system because of its small size, lightweight and low-cost. However, the induction machines do not have a source of excitation. Thus, it causes the inrush currents and the instantaneous voltage drop when the generator is directly connected to a power grid. To reduce the inrush currents, an AC power regulator is used. Wind power generations are frequently connected to and disconnected from the power grid. However, when the inrush currents are reduced, harmonic currents are caused by phase control of the AC power regulator. And the phase control of AC power regulator cannot control the power factor. Therefore, we propose the use of the AC power regulator to compensate for the harmonic currents and reactive power in the wind power generation system, and demonstrate the validity of its system by simulated and experimental results.

  6. Nuclear power generation and fuel cycle report 1997

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-09-01

    Nuclear power is an important source of electric energy and the amount of nuclear-generated electricity continued to grow as the performance of nuclear power plants improved. In 1996, nuclear power plants supplied 23 percent of the electricity production for countries with nuclear units, and 17 percent of the total electricity generated worldwide. However, the likelihood of nuclear power assuming a much larger role or even retaining its current share of electricity generation production is uncertain. The industry faces a complex set of issues including economic competitiveness, social acceptance, and the handling of nuclear waste, all of which contribute to the uncertain future of nuclear power. Nevertheless, for some countries the installed nuclear generating capacity is projected to continue to grow. Insufficient indigenous energy resources and concerns over energy independence make nuclear electric generation a viable option, especially for the countries of the Far East.

  7. Conceptual survey of Generators and Power Electronics for Wind Turbines

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, L.H.; Helle, L.; Blaabjerg, F.; Ritchie, E.; Munk-Nielsen, S.; Bindner, H.; Soerensen, P.; Bak-Jensen, B.

    2001-12-01

    This report presents a survey on generator concepts and power electronic concepts for wind turbines. The report is aimed as a tool for decision-makers and development people with respect to wind turbine manufactures, utilities, and independent system operators as well as manufactures of generators and power electronics. The survey is focused on the electric development of wind turbines and it yields an overview on: State of the art on generators and power electronics; future concepts and technologies within generators and power electronics; market needs in the shape of requirements to the grid connection, and; consistent system solutions, plus an evaluation of these seen in the prospect of market needs. This survey on of generator and power electronic concepts was carried out in co-operation between Aalborg University and Risoe National Laboratory in the scope of the research programme Electric Design and Control. (au)

  8. Numerical modelling of the process of heat transference, of the convective flow induced and the power generated in a wind power station; Modelizacion numerica del proceso de transferencia de calor, del flujo convectivo inducido y de la potencia generada en una central eolico solar

    Energy Technology Data Exchange (ETDEWEB)

    Hurtado, F. J.; Kaiser, A. S.; Zamora, B.; Lucas, M.; Viedma, A.

    2008-07-01

    A thermodynamic analysis for solar chimney power plant has been carried out by numerical simulation. A numerical model has been developed using the general purpose code Fluent to study heat transfer and convective flow within the chimney power plant. The {kappa}-{epsilon} turbulence model has been employed. A heat transfer, mass flow and power production numerical analysis has been carried out on different hours during the day, assuming steady state conditions. The numeric values obtained are 10% different from experimental measures. Once model has been validated, a numeric study about flow within power plant, heat transfer and mass flow has been carry out, and the non-dimensional parameters obtained have been compared with studies about free convection. (Author)

  9. Power generation from fuelwood by the Nicaraguan sugar mills

    NARCIS (Netherlands)

    Carneiro de Miranda, R.; Broek, R. van den

    2002-01-01

    With new concept development for the sugar industry and with new power market opportunities, two sugar mills in Nicaragua initiated projects aimed at becoming power plants during the sugar cane off-season. Basically the idea is to use more efficient boilers and turbines, and generate power beyond th

  10. Power generation from fuelwood by the Nicaraguan sugar mills

    NARCIS (Netherlands)

    Carneiro de Miranda, R.; Broek, R. van den

    1997-01-01

    With new concept development for the sugar industry and with new power market opportunities, two sugar mills in Nicaragua initiated projects aimed at becoming power plants during the sugar cane off-season. Basically the idea is to use more efficient boilers and turbines, and generate power beyond

  11. Power Maximization Control of Variable Speed Wind Generation System Using Permanent Magnet Synchronous Generator

    Science.gov (United States)

    Morimoto, Shigeo; Nakamura, Tomohiko; Takeda, Yoji

    This paper proposes the sensorless output power maximization control of the wind generation system. A permanent magnet synchronous generator (PMSG) is used as a variable speed generator in the proposed system. The generator torque is suitably controlled according to the generator speed and thus the power from a wind turbine settles down on the maximum power point by the proposed MPPT control method, where the information of wind velocity is not required. Moreover, the maximum available generated power is obtained by the optimum current vector control. The current vector of PMSG is optimally controlled according to the generator speed and the required torque in order to minimize the losses of PMSG considering the voltage and current constraints. The proposed wind power generation system can be achieved without mechanical sensors such as a wind velocity detector and a position sensor. Several experimental results show the effectiveness of the proposed control method.

  12. 280 burners reduce NOx emissions and improve boiler performance at Nanticoke power station

    Energy Technology Data Exchange (ETDEWEB)

    Burpee, J.; Tigges, K.-D.; Baehner, J. [Ontario Power Generation, Inc. (Canada)

    1999-07-01

    Describes work undertaken at the Nanticoke coal-fired power station (Canada), to convert the existing burners to low NO{sub x} burners to meet NO{sub x} reduction requirements and improve boiler performance. The burners on four units have already been modified and conversion work is been carried out on three other units. 280 modified coal burners are expected to be in operation by the end of 1999. 17 figs.

  13. Augmentation of coal handling plant for Nasik Thermal Power Station, India

    Energy Technology Data Exchange (ETDEWEB)

    Thakkar, M.C.; Bandhu, K.K.; Vyas, M.R.

    1989-08-01

    The augmentation of the coal handling plant at Nasik Thermal Power Station, India, was necessary, because the volume of coal to be handled increased due to the poor coal quality. The Maharashtra State Electricity Board therefore decided to install an additional conveying system consisting of a rotary-type wagon tippler (car dumper), a three-stage crushing plant, stacking and reclaiming equipment, and a motorized tripper bunkering system. 5 figs., 1 tab.

  14. Toess weir with small power station Pfungen; Toesswehr mit Kleinkraftwerk Pfungen

    Energy Technology Data Exchange (ETDEWEB)

    Haerri, R.W. [Amt fuer Gewaesserschutz und Wasserbau, Abt. Gewaesserkorrektionen, Zurich (Switzerland)

    1995-12-31

    Near Pfungen on the River Toess the Canton of Zurich replaced a dilapidated weir and utilises the available falling gradient with a small power station. Besides the production of renewable energy the assistance of a fish ladder has been made available. (orig.) [Deutsch] Bei Pfungen an der Toess ersetzte der Kanton Zuerich ein baufaelliges Wehr und nutzt das vorhandene Gefaelle mit einem Kleinkraftwerk. Neben der Erzeugung von erneuerbarer Energie kann nun mit Hilfe einer Treppe auch der Fischaufstieg gewaehrleistet werden. (orig.)

  15. [The evaluation of hazardous cinder wastes in Ulan Ude thermal power stations].

    Science.gov (United States)

    Borisenkova, R V; Dik, E P; Soboleva, A N; Lutsenko, L A

    2000-01-01

    Considering possibility of waste materials use in building materials production, the authors evaluated toxicity of ash and clinker waste of electric power stations in Ulan-Ude city. The ash dust and its tincture in water, when injected even in maximal amounts, induced no intoxication symptoms and death in experimental animals, therefore bear no toxicity. Using toxicity indexes to compare ash and clinker waste dust with nontoxic dust proved the studied waste to be nontoxic and acceptable for use in building industry.

  16. [Vegetation distribution in coal cinder yard of Wuhu thermal power station].

    Science.gov (United States)

    Wang, Youbao; Zhang, Li; Liu, Dengyi

    2002-12-01

    There are 30 species of natural colonized plants in the coal cinder yard of Wuhu thermal power station, and they are subordinate to 14 families and 29 genera. The main families are Compositae (7 species), Gramineae (6 species) and Leguminesae, among which, 18 species are annual plant, 9 species are perennial plant, and 2 species are woody plants. The chief factors limiting the vegetation distribution are extreme infertility and high concentration of heavy metals.

  17. FEATURES OF CALCULATION OF THE NONCONTACT ELECTRIC POWER GENERATORS

    Directory of Open Access Journals (Sweden)

    Kvitko A. V.

    2015-10-01

    Full Text Available The article shows that to improve the performance of autonomous systems we need new methods and principles of their design, associated with both the use of renewable sources and the application of new technical solutions of electromechanical generators and static stabilizers and inverters electric power settings. We have disclosed modern requirements for generators of electric power, as well as features of calculating the parameters of contactless electrical power generators: asynchronous generators capacitive excitation and asynchronous generators with permanent magnets. The article presents some analytical expressions for calculating the electrical losses and the efficiency of the generators, specific weight and power. It is shown, that expedient to designing contactless electrical power generators to carry out as part of the autonomous electricity supply systems, as it is sometimes advantageous to understate the main criteria of efficiency of generators, in order to improve, for example, weight and overall dimensions of static converters. The conclusion is made that in order to improve the efficiency of designing contactless electrical power generators in the early stages of designing it is necessary to carry out a preliminary assessment of the main criteria of efficiency of contactless electrical machines. We have also discussed analytical expressions, which might be used for preliminary evaluation of application features for various types of contactless generators in the stand-alone electricity supply systems taking into account the conditions of use

  18. Greener power generation technologies. Solutions for carbon capture

    Energy Technology Data Exchange (ETDEWEB)

    Reimuth, Oliver; Kremer, Hermann; Vortmeyer, Nicolas [Siemens AG, Erlangen (Germany)

    2011-07-01

    Fossil-based power generation will continue to account for a dominant share of over 50 % in the future energy mix. In order to meet the requirements of climate protection, a combination of highly-efficient, flexible combined cycle power plants and the use of CCS in coal-based power generation will be necessary. In addition to funding of the first demonstration projects comprehensive statutory framework and public acceptance are necessary for launching CCS technology. (orig.)

  19. Probabilistic forecasting of wind power generation using extreme learning machine

    DEFF Research Database (Denmark)

    Wan, Can; Xu, Zhao; Pinson, Pierre

    2014-01-01

    an extreme learning machine (ELM)-based probabilistic forecasting method for wind power generation. To account for the uncertainties in the forecasting results, several bootstrapmethods have been compared for modeling the regression uncertainty, based on which the pairs bootstrap method is identified...... demonstrate that the proposed method is effective for probabilistic forecasting of wind power generation with a high potential for practical applications in power systems....

  20. Process visualisation and multimedia for power station control of the future; Prozessvisualisierung und Multimedia fuer die Kraftwerksfuehrung von morgen

    Energy Technology Data Exchange (ETDEWEB)

    Herbst, L. [ABB Kraftwerksleittechnik GmbH, Mannheim (Germany)

    1994-11-14

    Advanced process control and modern process management require integration of many partial tasks. Advanced process control will include modern multi-media and communication technologies. The next generation of process control, developed by ABB had already been presented on trade fairs and includes large-screen projection, mass data visualisation and multimedia. This offers efficient, target-oriented and reliable power station control and integration of tasks. (orig.) [Deutsch] Fortschrittliche Prozessfuehrung und modernes Prozessmanagement erfordern die Integration vieler Teilaufgaben. Die Prozessfuehrung der Zukunft wird moderne Multimedia- und Kommunikationstechnologien enthalten. Die von ABB derzeit konzipierte, in Teilen bereits entwickelte und auf Messen praesentierte naechste Generation der Prozessfuehrung mit Grossbildprojektionen, Moeglichkeiten zur Massendatenvisualisierung und Multimedia ermoeglicht wirtschaftliche, zielgerichtete und zuverlaessige Kraftwerksfuehrung durch aufgabenvernetzte Zusammenarbeit. (orig.)