WorldWideScience

Sample records for gem gas amplification

  1. Study of reconstruction methods for a time projection chamber with GEM gas amplification system

    International Nuclear Information System (INIS)

    Diener, R.

    2006-12-01

    A new e + e - linear collider with an energy range up to 1TeV is planned in an international collaboration: the International Linear Collider (ILC). This collider will be able to do precision measurements of the Higgs particle and of physics beyond the Standard Model. In the Large Detector Concept (LDC) - which is one proposal for a detector at the ILC - a Time Projection Chamber (TPC) is foreseen as the main tracking device. To meet the requirements on the resolution and to be able to work in the environment at the ILC, the application of new gas amplification technologies in the TPC is necessary. One option is an amplification system based on Gas Electron Multipliers (GEMs). Due to the - in comparison with older technologies - small spatial width of the signals, this technology poses new requirements on the readout structures and the reconstruction methods. In this work, the performance and the systematics of different reconstruction methods have been studied, based on data measured with a TPC prototype in high magnetic fields of up to 4T and data from a Monte Carlo simulation. The latest results of the achievable point resolution are presented and their limitations have been investigated. (orig.)

  2. Study of reconstruction methods for a time projection chamber with GEM gas amplification system

    Energy Technology Data Exchange (ETDEWEB)

    Diener, R.

    2006-12-15

    A new e{sup +}e{sup -} linear collider with an energy range up to 1TeV is planned in an international collaboration: the International Linear Collider (ILC). This collider will be able to do precision measurements of the Higgs particle and of physics beyond the Standard Model. In the Large Detector Concept (LDC) - which is one proposal for a detector at the ILC - a Time Projection Chamber (TPC) is foreseen as the main tracking device. To meet the requirements on the resolution and to be able to work in the environment at the ILC, the application of new gas amplification technologies in the TPC is necessary. One option is an amplification system based on Gas Electron Multipliers (GEMs). Due to the - in comparison with older technologies - small spatial width of the signals, this technology poses new requirements on the readout structures and the reconstruction methods. In this work, the performance and the systematics of different reconstruction methods have been studied, based on data measured with a TPC prototype in high magnetic fields of up to 4T and data from a Monte Carlo simulation. The latest results of the achievable point resolution are presented and their limitations have been investigated. (orig.)

  3. A large ungated TPC with GEM amplification

    Science.gov (United States)

    Berger, M.; Ball, M.; Fabbietti, L.; Ketzer, B.; Arora, R.; Beck, R.; Böhmer, F. V.; Chen, J.-C.; Cusanno, F.; Dørheim, S.; García, F.; Hehner, J.; Herrmann, N.; Höppner, C.; Kaiser, D.; Kis̆, M.; Kleipa, V.; Konorov, I.; Kunkel, J.; Kurz, N.; Leifels, Y.; Müllner, P.; Münzer, R.; Neubert, S.; Rauch, J.; Schmidt, C. J.; Schmitz, R.; Soyk, D.; Vandenbroucke, M.; Voss, B.; Walther, D.; Zmeskal, J.

    2017-10-01

    A Time Projection Chamber (TPC) is an ideal device for the detection of charged particle tracks in a large volume covering a solid angle of almost 4 π. The high density of hits on a given particle track facilitates the task of pattern recognition in a high-occupancy environment and in addition provides particle identification by measuring the specific energy loss for each track. For these reasons, TPCs with Multiwire Proportional Chamber (MWPC) amplification have been and are widely used in experiments recording heavy-ion collisions. A significant drawback, however, is the large dead time of the order of 1 ms per event generated by the use of a gating grid, which is mandatory to prevent ions created in the amplification region from drifting back into the drift volume, where they would severely distort the drift path of subsequent tracks. For experiments with higher event rates this concept of a conventional TPC operating with a triggered gating grid can therefore not be applied without a significant loss of data. A continuous readout of the signals is the more appropriate way of operation. This, however, constitutes a change of paradigm with considerable challenges to be met concerning the amplification region, the design and bandwidth of the readout electronics, and the data handling. A mandatory prerequisite for such an operation is a sufficiently good suppression of the ion backflow from the avalanche region, which otherwise limits the tracking and particle identification capabilities of such a detector. Gas Electron Multipliers (GEM) are a promising candidate to combine excellent spatial resolution with an intrinsic suppression of ions. In this paper we describe the design, construction and the commissioning of a large TPC with GEM amplification and without gating grid (GEM-TPC). The design requirements have driven innovations in the construction of a light-weight field-cage, a supporting media flange, the GEM amplification and the readout system, which are

  4. The gas electron multiplier (GEM)

    CERN Document Server

    Bouclier, Roger; Dominik, Wojciech; Hoch, M; Labbé, J C; Million, Gilbert; Ropelewski, Leszek; Sauli, Fabio; Sharma, A

    1996-01-01

    We describe operating priciples and results obtained with a new detector component: the Gas Electrons Multiplier (GEM). Consisting of a thin composite sheet with two metal layers separated by a thin insulator, and pierced by a regular matrix of open channels, the GEM electrode, inserted on the path of electrons in a gas detector, allows to transfer the charge with an amplification factor approaching ten. Uniform response and high rate capability are demonstrated. Coupled to another device, multiwire or micro-strip chamber, the GEM electrode permit to obtain higher gains or less critical operation; separation of the sensitive (conversion) volume and the detection volume has other advantages, as a built-in delay (useful for triggering purposes) and the possibility of applying high fields on the photo-cathode of ring imaging detectors to improve efficiency. Multiple GEM grids in the same gas volume allow to obtain large amplification factors in a succession of steps, leading to the realization of an effective ga...

  5. GEM the gas electron multiplier

    CERN Document Server

    Sauli, Fabio

    1997-01-01

    We describe the basic structure and operation of a new device, the Gas Electron Multiplier. Consisting in a polymer foil, metal-clad on both sides and perforated by a high density of holes, the GEM mesh allows to pre-amplify charges released in the gas with good uniformity and energy. Coupled to a micro-strip plate, the pre-amplification element allows to preserve high rate capability and resolution at considerably lower operating voltages, thus completely eliminating discharges and instabilities. Several GEM grids can be operated in cascade; charge gains are large enough to allow detection of signals in the ionization mode on the last element, permitting the use of a simple printed circuit as read-out electrode. Two-dimensional read-out can then be easily implemented. A new generation of simple, reliable and cheap fast position sensitive detectors seems at hand.

  6. Further developments of the gas electron multiplier (GEM)

    CERN Document Server

    Benlloch, J M; Capéans-Garrido, M; Gruwé, M; Hoch, M; Labbé, J C; Placci, Alfredo; Ropelewski, Leszek; Sauli, Fabio

    1998-01-01

    We describe the development and operation of the Gas Electron Multiplier, a thin insulating foil metal-clad on both sides and perforated by a regular pattern of small holes. The mesh can be incorporat ed in the gas volume of an active detector to provide a first amplification channel for electrons, or used as stand alone. We report on the basic properties of GEMs manufactured with different geometr ies and operated in several gas mixtures as well as on their long-term stability after accumulation of charge equivalent to several years of operation in high luminosity experiments. Optimized GEMs re ach gains close to 10000 at safe operating voltages, permitting the detection of ionizing tracks, without other amplifying elements, on a simple printed circuit board (PCB), opening new possibilities for detector design.

  7. A new integrated photosensor for gas proportional scintillation counters based on the gas electron multiplier (GEM)

    CERN Document Server

    Lopes, J A M; Conde, C A N; Morgado, R E

    1999-01-01

    The performance of a novel integrated photosensor for use in a xenon gas proportional scintillation detector is described. Earlier integrated photo-sensor designs were limited in charge gains due to the onset of electrical breakdown, which was ascribed to optical positive feedback from scintillation photons produced in the charge amplification stage. The present design uses a gas electron multiplier (GEM) composed of a 50 mu m thick Kapton film with copper-plated electrode surfaces on both sides and perforated with 200 mu m holes at a 300 mu m pitch. The front surface is made photosensitive with a 150-nm-thick CsI film. When an appropriate voltage is applied between the copper electrodes, the resulting electric field directs photoelectrons produced on the front surface through the holes in the GEM and onto a wire chamber where charge amplification occurs. Optical positive feedback is essentially eliminated since the charge amplification stage is optically de-coupled from the photocathode. The GEM also provide...

  8. Gas electron multipliers: Development of large area GEMS and spherical GEMS

    International Nuclear Information System (INIS)

    Pinto, Serge Duarte

    2011-08-01

    Gaseous radiation detectors have been a crucial part of high-energy physics instrumentation since the 1960s, when the first multiwire proportional counters were built. In the 1990s the first micropattern gas detectors (MPGDS) saw the light; with sub-millimeter feature sizes these novel detectors were faster and more accurate than their predecessors. The gas electron multiplier (GEM) is one of the most successful of these technologies. It is a charge multiplication structure made from a copper clad polymer foil, pierced with a regular and dense pattern of holes. I describe the properties and the application of GEMs and GEM. detectors, and the research and development I have done on this technology. Two of the main objectives were the development of large area GEMs (∝m 2 ) for particle physics experiments and GEMs with a spherical shape for X-ray or neutron diffraction detectors. Both have been realized, and the new techniques involved are finding their way to applications in research and industry. (orig.)

  9. Gas Electron Multipliers: Development of large area GEMs and spherical GEMs

    CERN Document Server

    Duarte Pinto, Serge; Brock, Ian

    2011-01-01

    Gaseous radiation detectors have been a crucial part of high-energy physics instrumentation since the 1960s, when the first multiwire proportional counters were built. In the 1990s the first micropattern gas detectors (MPGDs) saw the light; with sub-millimeter feature sizes these novel detectors were faster and more accurate than their predecessors. The gas electron multiplier (GEM) is one of the most successful of these technologies. It is a charge multiplication structure made from a copper clad polymer foil, pierced with a regular and dense pattern of holes. I will describe the properties and the application of GEMs and GEM detectors, and the research and development I have done on this technology. Two of the main objectives were the development of large area GEMs (~m^2) for particle physics experiments and GEMs with a spherical shape for x-ray or neutron diffraction detectors. Both have been realized, and the new techniques involved are finding their way to applications in research and industry.

  10. Gas electron multipliers. Development of large area GEMS and spherical GEMS

    Energy Technology Data Exchange (ETDEWEB)

    Pinto, Serge Duarte

    2011-08-15

    Gaseous radiation detectors have been a crucial part of high-energy physics instrumentation since the 1960s, when the first multiwire proportional counters were built. In the 1990s the first micropattern gas detectors (MPGDS) saw the light; with sub-millimeter feature sizes these novel detectors were faster and more accurate than their predecessors. The gas electron multiplier (GEM) is one of the most successful of these technologies. It is a charge multiplication structure made from a copper clad polymer foil, pierced with a regular and dense pattern of holes. I describe the properties and the application of GEMs and GEM. detectors, and the research and development I have done on this technology. Two of the main objectives were the development of large area GEMs ({proportional_to}m{sup 2}) for particle physics experiments and GEMs with a spherical shape for X-ray or neutron diffraction detectors. Both have been realized, and the new techniques involved are finding their way to applications in research and industry. (orig.)

  11. Development of a glass GEM

    International Nuclear Information System (INIS)

    Takahashi, Hiroyuki; Mitsuya, Yuki; Fujiwara, Takeshi; Fushie, Takashi

    2013-01-01

    Gas electron multipliers (GEMs) apply the concept of gas amplification inside many tiny holes, realizing robust and high-gain proportional counters. However, the polyimide substrate of GEMs prevents them from being used in sealed detector applications. We have fabricated and tested glass GEMs (G-GEMs) with substrates made of photosensitive glass material from the Hoya Corporation. We fabricated G-GEMs with several different hole diameters and thicknesses and successfully operated test G-GEMs with a 100×100 mm 2 effective area. The uniformity of our G-GEMs was good, and the energy resolution for 5.9 keV X-rays was 18.8% under uniform irradiation of the entire effective area. A gas gain by the G-GEMs of up to 6700 was confirmed with a gas mixture of Ar (70%)+CH 4 (30%). X-ray imaging using the charge division readout method was demonstrated

  12. GEMS

    Science.gov (United States)

    Swank, Jean

    2009-01-01

    The prime scientific objectives of the Gravity and Extreme Magnetism SMEX, GEMS, are to determine the effects of the spin of black holes, the configurations of the magnetic fields of magnetars, and the structure of the supernova shocks which accelerate cosmic rays. In the cases of both stellar black holes and supermassive black holes, sensitivity to 1% polarization is needed to make diagnostic measurements of the net polarizations predicted for probable disk and corona models. GEMS can reach this goal for several Seyferts and quasars and measure the polarizations of representatives of a variety of other classes of X-ray sources, such as rotation-powered and accretion-powered pulsars. GEMS uses foil mirrors to maximize the collecting area achievable within the SMEX constraints. The polarimeters at the mirror foci are Time Projection Chambers which use the photoelectic effect to measure the polarization of the incident photon. We have built laboratory models with good efficiency and modulation in the 2-10 keV range. An attached small student experiment would add 0.5 keV sensitivity for bright soft sources. The instrument has a point spread function which allows measurement of structures in the brighter nearby supernova remnants. GEMS' Orbital Sciences spacecraft will rotate at a rate of 0.1 revolutions per minute during observations, so that systematic errors due to the detector can be detected and corrected. A program of 35 sources can be observed in 9 months. GEMS is designed for a two year lifetime which will allow a General Observer program that would more than double the number of sources measured. For subsets of black holes, neutron stars and supernova remnants, GEMS will measure the polarization of several sources, solving important questions while establishing the sensitivity required for future missions.

  13. Radiation imaging with glass gas electron multipliers (G -GEMs)

    Science.gov (United States)

    Fujiwara, Takeshi; Mitsuya, Yuki; Takahashi, Hiroyuki

    2018-01-01

    This review investigates the advantages and disadvantages of gaseous radiation detectors when compared with solid-state detectors, for use in radiation imaging, which are caused by the differing properties of gases and solids. Imaging applications for which micro-pattern gas detectors (MPGDs) are superior, include neutron imaging, high-linear-energy-transfer (LET) radiation imaging, and low-energy-depositing radiation imaging. This paper is focused on these applications where MPGDs, in particular, the glass gas electron multiplier (G-GEM), are superior, and their development is described and relevant experimental results are discussed.

  14. Gas electron multiplier (GEM) operation with tissue-equivalent gases at various pressures

    International Nuclear Information System (INIS)

    Farahmand, M.; Bos, A.J.J.; Eijk, C.W.E. van

    2003-01-01

    We have studied the operation of two different Gas Electron Multiplier (GEM) structures in both methane and propane based Tissue-Equivalent (TE) gases at different pressures varying from 0.1 to 1 atm. This work was motivated to explore the possibility of using a GEM for a new type of Tissue Equivalent Proportional Counter. In methane based TE gas, a maximum safe GEM gain of 1.5x10 3 has been reached while in propane based TE gas this is 6x10 3 . These maxima have been reached at different gas pressures depending on GEM structure and TE gas. Furthermore, we observed a decrease of the GEM gain in time before it becomes stable. Charge up/polarisation effects can explain this

  15. The current status of the Gas Electron Multiplier (GEM) research at Kasetsart University, Thailand

    Science.gov (United States)

    Kumpiranon, P.; Kulasri, K.; Rittirong, A.; Saenboonruang, K.

    2017-06-01

    During the past decade, Gas Electron Multiplier (GEM) detectors have been greatly developed and utilized in numbers of applications including advanced nuclear and particle researches, medical imaging, astrophysics, and neutron detection for national security. Our GEM research group at the Department of Applied Radiation and Isotopes, Faculty of Science, Kasetsart University, Thailand, realized in its excellent properties/potentials and started extensive researches on GEM detectors. To build a strong foundation on our research group, two 10 cm × 10 cm triple GEM detectors were characterized on their important properties including absolute gains and detection uniformity. Moreover, to widen applications of the GEM detector, our group had modified the GEM detector by introducing either solid or gaseous neutron converters to the detector so that the detector could effectively detect neutrons. These modifications included coating a thin film of 10B and natB to the GEM drift cathode for thermal neutron detection and flowing a gas mixture of He/CO2 (80:20 and 70:30) and C4H10/He/CO2 (7:70:23) for fast neutron detection. Results showed that the modified GEM-based neutron detector could detect both types of neutrons with different relative efficiencies and gains depending on thicknesses and types of neutron converters. This article discusses basic knowledge of the GEM detector, construction and testing procedures, results, and discussion.

  16. Quality Control (QC2) of Gas Electron Multiplier (GEM) for GE1/1 at CMS Experiment

    CERN Document Server

    Sharma, Archana

    2016-01-01

    Gas Electron Multiplier (GEM) is a gas ionization detector that detect charged particles and will be implemented on CMS system. It is designed to improve muon trigger and tracking performance at high luminosity after the second Long Shutdown (LS2). For my project, GEM foils, a component of the Triple GEM detector have been studied. In order to pass the test, the foils need to run in the Fast Test and Long Test of QC2.

  17. Gas Purity Effect on GEM Performance in He and Ne at Low Temperatures

    Science.gov (United States)

    Galea, R.; Dodd, J.; Ju, Y.; Leltchouk, M.; Willis, W.; Rehak, P.; Tcherniatine, V.; Buzulutskov, A.; Pavlyuchenko, D.

    2006-08-01

    The performance of Gas Electron Multipliers (GEMs) in gaseous He, Ne, He+H2 and Ne+H2 was studied at temperatures in the range of 3-293 K. This paper reports on previously published measurements and additional studies on the effects of the purity of the gases in which the GEM performance is evaluated. In He, at temperatures between 77 and 293 K, triple-GEM structures operate at rather high gains, exceeding 1000. There is an indication that this high gain is achieved through the Penning effect as a result of impurities in the gas. At lower temperatures the gain-voltage characteristics are significantly modified probably due to the freeze-out of these impurities. Double-GEM and single-GEM structures can operate down to 3 K at gains reaching only several tens at a gas density of about 0.5 g/l; at higher densities the maximum gain drops further. In Ne, the maximum gain also drops at cryogenic temperatures. The gain drop in Ne at low temperatures can be re-established in Penning mixtures of Ne+H2: very high gains, exceeding 104, have been obtained in these mixtures at 30-77 K, at a density of 9.2 g/l which corresponds to saturated Ne vapor density at 27 K. The addition of small amounts of H2 in He also re-establishes large GEM gains above 30 K but no gain was observed in He+H2 at 4 K and a density of 1.7 g/l (corresponding to roughly one-tenth of the saturated vapor density). These studies are, in part, being pursued in the development of two-phase He and Ne detectors for solar neutrino detection.

  18. A triple-GEM telescope for the TOTEM experiment

    CERN Document Server

    Lami, S; Oliveri, E; Ropelewski, Leszek; Turini, N

    2007-01-01

    The TOTEM experiment at LHC has chosen the triple Gas Electron Multiplier (GEM) technology for its T2 telescope which will provide charged track reconstruction in the rapidity range 5.3<|eta|<6.5 and a fully inclusive trigger for diffractive events. GEMs are gas-filled detectors that have the advantageous decoupling of the charge amplification structure from the charge collection and readout structure. Furthermore, they combine good spatial resolution with very high rate capability and a good resistance to radiation. Results from a detailed T2 GEM simulation and from laboratory tests on a final design detector performed at CERN are presented.

  19. Aging measurements on triple-GEM detectors operated with $CF_{4}$-based gas mixtures

    CERN Document Server

    Alfonsi, M; De Simone, P; Murtas, F; Poli Lener, M P; Bonivento, W; Cardini, A; Raspino, D; Saitta, B; Pinci, D; Baccaro, S; 10.1016/j.nuclphysbps.2005.03.054

    2006-01-01

    We present the results of a global irradiation test of full size triple-GEM detectors operated with CF/sub 4/-based gas mixtures. This study has been performed in the framework of an R&D activity on detectors for the innermost region of the first muon station of the LHCb experiment. The prototypes have been irradiated at the Calliope facility of the ENEA-Casaccia with a high intensity 1.25 MeV detectors performances have been measured with X-rays and with a 3 Ge V pion beam at CERN. A SEM analysis on several samples of the detectors has been performed to complete the understanding of the physical processes occurring in a GEM detector during a strong irradiation.

  20. Aging measurements on triple-GEM detectors operated with $CF_{4}$- based gas mixtures

    CERN Document Server

    Alfonsi, M; Bencivenni, G; Bonivento, W; Cardini, A; Lener, M P; Murtas, F; Pinci, D; Raspino, D; Saitta, B; De Simone, P

    2004-01-01

    We present the results of a global irradiation test of full size triple-GEM detectors operated with CF/sub 4/-based gas mixtures. This study has been performed in the framework of an R&D activity on detectors for the innermost region of the first muon station of the LHCb experiment. The prototypes have been irradiated at the Calliope facility of the ENEA-Casaccia with a high intensity 1.25 MeV gamma from a /sup 60/Co source. After the irradiation test the detectors performances have been measured with X-rays and with a 3 GeV pion beam at CERN. A SEM analysis on several samples of the detectors has been performed to complete the understanding of the physical processes occurring in the GEM detector during the strong irradiation.

  1. Aging measurements on triple-GEM detectors operated with CF{sub 4}-based gas mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Alfonsi, M. [Laboratori Nazionali di Frascati - INFN, Frascati (Italy); Bencivenni, G. [Laboratori Nazionali di Frascati - INFN, Frascati (Italy); De Simone, P. [Laboratori Nazionali di Frascati - INFN, Frascati (Italy); Murtas, F. [Laboratori Nazionali di Frascati - INFN, Frascati (Italy); Poli Lener, M. [Laboratori Nazionali di Frascati - INFN, Frascati (Italy); Bonivento, W. [Sezione INFN di Cagliari, Cagliari (Italy); Cardini, A. [Sezione INFN di Cagliari, Cagliari (Italy); Raspino, D. [Sezione INFN di Cagliari, Cagliari (Italy); Saitta, B. [Sezione INFN di Cagliari, Cagliari (Italy); Pinci, D. [Sezione INFN di Roma 1, Rome (Italy); Baccaro, S. [ENEA-FIS/ION, C.R. Casaccia, 00060, S. Maria di Galeria (Rome) (Italy)

    2006-01-15

    We present the results of a global irradiation test of full size triple-GEM detectors operated with CF{sub 4}-based gas mixtures. This study has been performed in the framework of an R and D activity on detectors for the innermost region of the first muon station of the LHCb experiment. The prototypes have been irradiated at the Calliope facility of the ENEA-Casaccia with a high intensity 1.25 MeV {gamma} {sup 6}Co source. After the irradiation test the detectors performances have been measured with X-rays and with a 3 GeV pion beam at CERN. A SEM analysis on several samples of the detectors has been performed to complete the understanding of the physical processes occurring in a GEM detector during a strong irradiation.

  2. GEM: Performance and aging tests

    International Nuclear Information System (INIS)

    Cho, H.S.; Kadyk, J.; Han, S.H.; Hong, W.S.; Perez-Mendez, V.; Wenzel, W.; Pitts, K.; Martin, M.D.; Hutchins, J.B.

    1999-01-01

    Performance and aging tests have been done to characterize Gas Electron Multipliers (GEMs), including further design improvements such as a thicker GEM and a closed GEM. Since the effective GEM gain is typically smaller than the absolute GEM gain, due to trapping of avalanche electrons at the bottom GEM electrode, the authors performed field simulations and measurements for better understanding, and discuss methods to eliminate this effect. Other performance parameters of the GEMs are also presented, including absolute GEM gain, short-term and long-term gain stabilities

  3. Charge amplification and transfer processes in the gas electron multiplier

    International Nuclear Information System (INIS)

    Bachmann, S.; Bressan, A.; Ropelewski, L.; Sauli, F.; Sharma, A.; Moermann, D.

    1999-01-01

    We report the results of systematic investigations on the operating properties of detectors based on the gas electron multiplier (GEM). The dependence of gain and charge collection efficiency on the external fields has been studied in a range of values for the hole diameter and pitch. The collection efficiency of ionization electrons into the multiplier, after an initial increase, reaches a plateau extending to higher values of drift field the larger the GEM voltage and its optical transparency. The effective gain, fraction of electrons collected by an electrode following the multiplier, increases almost linearly with the collection field, until entering a steeper parallel plate multiplication regime. The maximum effective gain attainable increases with the reduction in the hole diameter, stabilizing to a constant value at a diameter approximately corresponding to the foil thickness. Charge transfer properties appear to depend only on ratios of fields outside and within the channels, with no interaction between the external fields. With proper design, GEM detectors can be optimized to satisfy a wide range of experimental requirements: tracking of minimum ionizing particles, good electron collection with small distortions in high magnetic fields, improved multi-track resolution and strong ion feedback suppression in large volume and time-projection chambers

  4. Gas scintillation glass GEM detector for high-resolution X-ray imaging and CT

    Energy Technology Data Exchange (ETDEWEB)

    Fujiwara, T., E-mail: fujiwara-t@aist.go.jp [Research Institute for Measurement and Analytical Instrumentation, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki 305-8568 (Japan); Mitsuya, Y. [Nuclear Professional School, The University of Tokyo, Tokai, Naka, Ibaraki 319-1188 (Japan); Fushie, T. [Radiment Lab. Inc., Setagaya, Tokyo 156-0044 (Japan); Murata, K.; Kawamura, A.; Koishikawa, A. [XIT Co., Naruse, Machida, Tokyo 194-0045 (Japan); Toyokawa, H. [Research Institute for Measurement and Analytical Instrumentation, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki 305-8568 (Japan); Takahashi, H. [Institute of Engineering Innovation, School of Engineering, The University of Tokyo, Bunkyo, Tokyo 113-8654 (Japan)

    2017-04-01

    A high-spatial-resolution X-ray-imaging gaseous detector has been developed with a single high-gas-gain glass gas electron multiplier (G-GEM), scintillation gas, and optical camera. High-resolution X-ray imaging of soft elements is performed with a spatial resolution of 281 µm rms and an effective area of 100×100 mm. In addition, high-resolution X-ray 3D computed tomography (CT) is successfully demonstrated with the gaseous detector. It shows high sensitivity to low-energy X-rays, which results in high-contrast radiographs of objects containing elements with low atomic numbers. In addition, the high yield of scintillation light enables fast X-ray imaging, which is an advantage for constructing CT images with low-energy X-rays.

  5. Gain uniformity experimental study performed on triple-GEM gas detector

    International Nuclear Information System (INIS)

    Dong Liyuan; Qi Huirong; Lu Xinyu; Ouyang Qun; Chen Yuanbo; Li Yuhong

    2012-01-01

    With the application of the two-dimensional GEM gaseous detector in X-ray imaging, the correction method of gain uniformity caused by triple-GEM avalanche structures and electric field uniformity should be studied. The paper reported the study of the triple-GEM detector with effective area 100 mm × 100 mm used the Pad's size of 9.5 mm × 9.5 mm. In the test, 100 readout channels were designed. Results showed that gain remained stable over time; at air flow increases, gain from increases obviously to changes very little. Particularly, triple-GEM's gain uniformity was very good (more than 80%) and the range of energy resolution was from 0.18 to 0.2. To improve gain consistency of results, the difference value revised was obtained to be about 0.1 by the least square method. It provided a better method to improve gain uniformity of GEM detector. (authors)

  6. A how-to approach for a 3D simulation of charge transfer characteristics in a gas electron multiplier (GEM)

    CERN Document Server

    Sharma, A

    1999-01-01

    In this paper a detailed description of how to simulate charge transfer processes in a gaseous device is presented, taking the gas electron multiplier (GEM) as an example. A 3-dimensional simulation of the electric field and avalanche is performed. Results on charge transport are compared to experiment and agree within experimental errors; the avalanche mechanism and positive ion feedback are studied. The procedures used in the simulation are described in detail, and program scripts are appended. (15 refs).

  7. GEM - A novel gaseous particle detector

    CERN Document Server

    Meinschad, T

    2005-01-01

    The work carried out within the framework of this Ph.D. deals with the construction of gaseous prototype detectors using Gas Electron Multiplier electrodes for the amplification of charges released by ionizing particles. The Gas Electron Multiplier (GEM) is a thin metal-clad polymer foil, etched with a high density of narrow holes, typically 50-100mm-2. On the application of a potential difference between the conductive top and bottom sides each hole acts as independent proportional counter. This new fast device permits to reach large amplification factors at high rates with a strong photon and ion-mediated feedback suppression due to the avalanche confinement in the GEM-holes. Here, in particular studies have been performed, which should prove, that the GEM-technology is applicable for an efficient measurement of single Cherenkov photons. These UV-photons can be detected in different ways. An elegant solution to develop large area RICH-detectors is to evaporate a pad-segmented readout-cathode of a multi-wire...

  8. An extended parametrization of gas amplification in proportional wire chambers

    International Nuclear Information System (INIS)

    Beingessner, S.P.; Carnegie, R.K.; Hargrove, C.K.

    1987-01-01

    It is normally assumed that the gas amplification in proportional chambers is a function of Townsend's first ionization coefficient, α, and that α is a function of the anode surface electric field only. Experimental measurements are presented demonstrating the breakdown of the latter assumption for electric fields, X, greater than about 150 V/cm/Torr on the anode wire surface for a gas mixture of 80/20 argon/methane. For larger values of X, the parametrization of the proportional gas gain data requires an additional term related to the gradient of the electric field near the wire. This extended gain parametrization remains valid until the onset of nonproportional contributions such as positive ion space charge saturation effects. Furthermore, deviations of the data from this parametrization are used to measure the onset of these space charge effects. A simple scaling dependence of the gain data on the product of pressure and wire radius over the whole proportional range is also demonstrated. (orig.)

  9. Gas Electron Multipler (GEM) detectors for parity-violating electron scattering experiments at Jefferson Lab

    Science.gov (United States)

    Matter, John; Gnanvo, Kondo; Liyanage, Nilanga; Solid Collaboration; Moller Collaboration

    2017-09-01

    The JLab Parity Violation In Deep Inelastic Scattering (PVDIS) experiment will use the upgraded 12 GeV beam and proposed Solenoidal Large Intensity Device (SoLID) to measure the parity-violating electroweak asymmetry in DIS of polarized electrons with high precision in order to search for physics beyond the Standard Model. Unlike many prior Parity-Violating Electron Scattering (PVES) experiments, PVDIS is a single-particle tracking experiment. Furthermore the experiment's high luminosity combined with the SoLID spectrometer's open configuration creates high-background conditions. As such, the PVDIS experiment has the most demanding tracking detector needs of any PVES experiment to date, requiring precision detectors capable of operating at high-rate conditions in PVDIS's full production luminosity. Developments in large-area GEM detector R&D and SoLID simulations have demonstrated that GEMs provide a cost-effective solution for PVDIS's tracking needs. The integrating-detector-based JLab Measurement Of Lepton Lepton Electroweak Reaction (MOLLER) experiment requires high-precision tracking for acceptance calibration. Large-area GEMs will be used as tracking detectors for MOLLER as well. The conceptual designs of GEM detectors for the PVDIS and MOLLER experiments will be presented.

  10. Commercial and Cost Effective Production of Gas Electron Multiplier (GEM) Foils

    Energy Technology Data Exchange (ETDEWEB)

    Woody, Craig

    2009-03-31

    The nuclear and high energy physics research community is constantly searching for new and improved tracking and radiation detectors. The introduction of micropattern detectors has opened new opportunities for improving the rate capabilities, as well as the spatial and time resolution of particle detectors in these applications. GEM detectors in particular have received enormous interest for use in detectors planned for a number of new and upgraded experiments at many different research facilities. These include both the STAR and PHENIX experiments at the Relativistic Heavy Ion Collider at Brookhaven National Laboratory, experiments at the Thomas Jefferson National Laboratory, Oak Ridge National Laboratory, and at the future electron-positron Linear Collider. At the present time, CERN is not able to supply foils in sufficient quantities to accommodate the needs of these experiments. Compounding this problem, there is a strong interest in GEM foils for numerous other applications, such as in astrophysics, medical imaging and detectors for homeland security. It would therefore be of significant benefit to the research community to develop a commercial source of GEM foils for all of these applications. Tech-Etch is in a unique position to develop this technology for commercial use. Tech-Etch has not only experience in numerous related high precision etched Kapton® products, but it also has strong ties with several research institutions (namely Brookhaven, Yale and MIT) that can help develop and evaluate the performance of the GEM foils produced at Tech-Etch. Additionally, since Tech-Etch is a small company, it also has the capability to produce a large variety of part configurations, as well as the flexibility to shift production methods, equipment, and chemistry to optimize the GEM foil manufacturing process without being constrained by existing work running on high volume continuous coil equipment.

  11. Muon Chamber Endcap Upgrade of the CMS Experiment with Gas Electron Multiplier (GEM) Detectors and their Performance

    CERN Document Server

    Gola, Mohit

    2017-01-01

    As the CERN LHC is heading towards a high luminosity phase a very high flux is expected in the endcaps of the CMS Detector. The presence of muons in collision events can be due to rare or new physics so it is important to maintain the high trigger efficiency of the CMS muon system. The CMS Collaboration has proposed to instrument the high-eta region (1.6 lt IetaI lt 2.2) of the muon endcaps with Gas Electron Multiplier (GEM) detectors, referred to as GE1/1 chambers, during the LS2. This technology will help in maintaining optimum trigger performance with maximum selection efficiency of muons even in a high flux environment. We describe plans for a Slice Test to installa few GE1/1 chambers covering 50 degrees in azimuthal angle within the CMS detector in 2017, with subsequent operation during the current Run 2 of the LHC. We show the performance of the GE1/1 chambers to be installed during the slice test, specifically GEM foil leakage currents, chamber gas volume integrity, high voltage circuit performanc...

  12. Evaluation of the optimum induction gap for the GEM-MIGAS

    International Nuclear Information System (INIS)

    Mir, J.A.; Rhodes, N.J.; Schooneveld, E.M.; Conceicao, A.S.; Maia, J.M.; Veloso, J.F.C.A.; dos Santos, J.M.F.

    2009-01-01

    A gas electron multiplier with a micro-induction gap amplifying structure (GEM-MIGAS) is formed when a conventional GEM is operated with a short induction gap, typically set at 50 μm. The main aims of this study were to examine the charge amplification in the induction gap of the GEM-MIGAS and then to evaluate the optimum induction gap thickness for achieving the maximum charge amplification in the region. For the present study, the GEM-MIGAS was operated in the gas flow mode using He/iso-C 4 H 10 (85/15%). It was also possible to determine the optimum gap thickness, where the dependence of the charge amplification was least sensitive to the small variations of the gap thickness and to the ambient variables, such as pressure and temperature. This was accomplished by setting the voltage across the GEM-holes to a small value as to allow the transfer of electrons from the drift region into the induction region, without incurring multiplication within the holes. Through parametric curve fitting of the charge gain-induction gap voltage characteristics, the optimum induction gap for sustaining highest charge gains was evaluated and compared with trends observed using a conventional Micromegas.

  13. GEM simulation methods development

    International Nuclear Information System (INIS)

    Tikhonov, V.; Veenhof, R.

    2002-01-01

    A review of methods used in the simulation of processes in gas electron multipliers (GEMs) and in the accurate calculation of detector characteristics is presented. Such detector characteristics as effective gas gain, transparency, charge collection and losses have been calculated and optimized for a number of GEM geometries and compared with experiment. A method and a new special program for calculations of detector macro-characteristics such as signal response in a real detector readout structure, and spatial and time resolution of detectors have been developed and used for detector optimization. A detailed development of signal induction on readout electrodes and electronics characteristics are included in the new program. A method for the simulation of charging-up effects in GEM detectors is described. All methods show good agreement with experiment

  14. Graphics gems

    CERN Document Server

    Glassner, Andrew S

    1993-01-01

    ""The GRAPHICS GEMS Series"" was started in 1990 by Andrew Glassner. The vision and purpose of the Series was - and still is - to provide tips, techniques, and algorithms for graphics programmers. All of the gems are written by programmers who work in the field and are motivated by a common desire to share interesting ideas and tools with their colleagues. Each volume provides a new set of innovative solutions to a variety of programming problems.

  15. Development of a Diehard GEM using PTFE insulator substrate

    OpenAIRE

    Wakabayashi, M.; Komiya, K.; Tamagawa, T.; Takeuchi, Y.; Aoki, K.; Taketani, A.; Hamagaki, H.

    2014-01-01

    We have developed the gas electron multiplier (GEM) using polytetrafluoroethylene (PTFE) insulator substrate (PTFE-GEM). Carbonization on insulator layer by discharges shorts the GEM electrodes, causing permanent breakdown. Since PTFE is hard to be carbonized against arc discharges, PTFE-GEM is expected to be robust against breakdown. Gains as high as 2.6x10^4 were achieved with PTFE-GEM (50 um thick) in Ar/CO2 = 70%/30% gas mixture at V_GEM = 730V. PTFE-GEM never showed a permanent breakdown...

  16. Analysis of GEM properties and development of a GEM support structure for the ILD time projection chamber

    Energy Technology Data Exchange (ETDEWEB)

    Hallermann, Lea

    2010-04-15

    In the concept of the International Large Detector (ILD), developed for the International Linear Collider (ILC) a Time Projection Chamber (TPC) is envisaged as main tracking detector. Such gaseous detectors have to be equipped with amplification devices in order to enlarge the amount of charge, which is set free by ionization caused by traversing charged particles. Micro Pattern Gas Detectors (MPGDs) will be used in the ILD TPC as amplification stage. In this thesis, Gas Electron Multipliers (GEMs) - one specific MPGD species - are analyzed concerning various properties. Effective gains and energy resolutions are compared for GEM foils produced by different manufacturers. A good understanding of these observables is obtained by interpretation of the results with the help of geometrical parameters. Height profile measurements of GEM foils have been performed for the first time and the impact of non perfect flat GEMs is analyzed, especially on dE/dx determination and drift field quality. The results emphasize the need of a flat installation of GEMs in TPCs. As a consequence, a new mounting device has been developed to ensure flatness and to provide a method to cover large readout areas, as in the ILD TPC, by introducing the least possible amount of dead material into the detector. The developed structure has been tested in a TPC protoype, taking cosmic muon data. The influence of the mounting on track reconstruction, single point resolution, tracking efficiency and dE/dx measurements is quantified. The developed mounting is applicable in a large scale TPC, if some design considerations are taken into account. (orig.)

  17. Analysis of GEM properties and development of a GEM support structure for the ILD time projection chamber

    International Nuclear Information System (INIS)

    Hallermann, Lea

    2010-04-01

    In the concept of the International Large Detector (ILD), developed for the International Linear Collider (ILC) a Time Projection Chamber (TPC) is envisaged as main tracking detector. Such gaseous detectors have to be equipped with amplification devices in order to enlarge the amount of charge, which is set free by ionization caused by traversing charged particles. Micro Pattern Gas Detectors (MPGDs) will be used in the ILD TPC as amplification stage. In this thesis, Gas Electron Multipliers (GEMs) - one specific MPGD species - are analyzed concerning various properties. Effective gains and energy resolutions are compared for GEM foils produced by different manufacturers. A good understanding of these observables is obtained by interpretation of the results with the help of geometrical parameters. Height profile measurements of GEM foils have been performed for the first time and the impact of non perfect flat GEMs is analyzed, especially on dE/dx determination and drift field quality. The results emphasize the need of a flat installation of GEMs in TPCs. As a consequence, a new mounting device has been developed to ensure flatness and to provide a method to cover large readout areas, as in the ILD TPC, by introducing the least possible amount of dead material into the detector. The developed structure has been tested in a TPC protoype, taking cosmic muon data. The influence of the mounting on track reconstruction, single point resolution, tracking efficiency and dE/dx measurements is quantified. The developed mounting is applicable in a large scale TPC, if some design considerations are taken into account. (orig.)

  18. Numerical Investigation on Electron and Ion Transmission of GEM-based Detectors

    Science.gov (United States)

    Bhattacharya, Purba; Sahoo, Sumanya Sekhar; Biswas, Saikat; Mohanty, Bedangadas; Majumdar, Nayana; Mukhopadhyay, Supratik

    2018-02-01

    ALICE at the LHC is planning a major upgrade of its detector systems, including the TPC, to cope with an increase of the LHC luminosity after 2018. Different R&D activities are currently concentrated on the adoption of the Gas Electron Multiplier (GEM) as the gas amplification stage of the ALICE-TPC upgrade version. The major challenge is to have low ion feedback in the drift volume as well as to ensure a collection of good percentage of primary electrons in the signal generation process. In the present work, Garfield simulation framework has been adopted to numerically estimate the electron transparency and ion backflow fraction of GEM-based detectors. In this process, extensive simulations have been carried out to enrich our understanding of the complex physical processes occurring within single, triple and quadruple GEM detectors. A detailed study has been performed to observe the effect of detector geometry, field configuration and magnetic field on the above mentioned characteristics.

  19. Preliminary results of the Gas Electron Multiplier (GEM) as real-time beam monitor in hadron therapy

    Energy Technology Data Exchange (ETDEWEB)

    Aza, E., E-mail: eleni.aza@cern.ch [CERN, Geneva 23, 1211 Geneva (Switzerland); AUTH, Department of Physics, 54124 Thessaloniki (Greece); Ciocca, M. [Fondazione CNAO, Strada Campeggi 53, 27100 Pavia (Italy); Murtas, F. [CERN, Geneva 23, 1211 Geneva (Switzerland); LNF-INFN, Via Fermi 40, 00044 Frascati (Italy); Puddu, S. [CERN, Geneva 23, 1211 Geneva (Switzerland); AEC-LHEP, University of Bern, Sidlerstrasse 5, 3012 Bern (Switzerland); Pullia, M. [Fondazione CNAO, Strada Campeggi 53, 27100 Pavia (Italy); Silari, M. [CERN, Geneva 23, 1211 Geneva (Switzerland)

    2017-01-01

    The use of proton and carbon ion beams in cancer therapy (also known as hadron therapy) is progressively growing worldwide due to their improved dose distributions, sparing of healthy tissues and (for carbon ions) increased radiobiological effectiveness especially for radio-resistant tumours. Strict Quality Assurance (QA) protocols need to be followed for guaranteeing the clinical beam specifications. The aim of this study was to assess the performance of a gaseous detector based on the Gas Electron Multiplier (GEM) technology for measuring the beam spot dimensions and the homogeneity of the scanned irradiation field, which are daily QA tasks commonly performed using radiochromic films. Measurements performed at the National Centre for Oncological Hadron Therapy (CNAO) in Pavia (Italy) showed that the detector is able to monitor the 2D beam image on-line with a pad granularity of 2 mm and a response proportional to the number of delivered particles. The dose homogeneity was measured with low deviation from the results obtained with radiochromic films.

  20. Resonant amplification of quantum fluctuations in a spinor gas

    DEFF Research Database (Denmark)

    Topic, O.; Scherer, M.; Gebreyesus, G.

    2010-01-01

    Bose-Einstein condensates of atoms with non-zero spin are known to constitute an ideal system to investigate fundamental properties of magnetic superfluids. More recently it was realized that they also provide the fascinating opportunity to investigate the macroscopic amplification of quantum...... and classical fluctuations. This is strikingly manifested in a sample initially prepared in the m F = 0 state, where spin-changing collisions triggered by quantum fluctuations may lead to the creation of correlated pairs in m F = ±1. We show that the pair creation efficiency is strongly influenced...... by the interplay between the external trapping potential and the Zeeman effect. It thus reflects the confinement-induced magnetic field dependence of elementary spin excitations of the condensate. Remarkably, pair production in our experiments is therefore characterized by a multi-resonant dependence...

  1. Development of a Diehard GEM using PTFE insulator substrate

    International Nuclear Information System (INIS)

    Wakabayashi, M; Tamagawa, T; Takeuchi, Y; Aoki, K; Taketani, A; Komiya, K; Hamagaki, H

    2014-01-01

    We have developed the gas electron multiplier (GEM) using polytetrafluoroethylene (PTFE) insulator substrate (PTFE-GEM). Carbonization on insulator layer by discharges shorts the GEM electrodes, causing permanent breakdown. Since PTFE is hard to be carbonized against arc discharges, PTFE-GEM is expected to be robust against breakdown. Gains as high as 2.6 × 10 4 were achieved with PTFE-GEM (50 μm thick) in Ar/CO 2 = 70%/30% gas mixture at V GEM = 730 V. PTFE-GEM never showed a permanent breakdown even after suffering more than 40000 times discharges during the experiment. The result demonstrates that PTFE-GEM is really robust against discharges. We conclude that PTFE is an excellent insulator material for the GEM productions

  2. GEM scintillation readout with avalanche photodiodes

    CERN Document Server

    Conceição, A S; Fernandes, L M P; Monteiro, C M B; Coelho, L C C; Azevedo, C D R; Veloso, J F C A; Lopesac, J A M; dos Santosa, J M F

    2007-01-01

    The use of the scintillation produced in the charge avalanches in GEM holes as signal amplification and readout is investigated for xenon. A VUV-sensitive avalanche photodiode has been used as photosensor. Detector gains of about 4 × 104 are achieved in scintillation readout mode, for GEM voltages of 490 V and for a photosensor gain of 150. Those gains are more than one order of magnitude larger than what is obtained using charge readout. In addition, the energy resolutions achieved with the scintillation readout are lower than those achieved with charge readout. The GEM scintillation yield in xenon was measured as a function of GEM voltage, presenting values that are about a half of those achieved for the charge yield, and reach about 730 photons per primary electron at GEM voltages of 490 V.

  3. 3D simulation of electron and ion transmission of GEM-based detectors

    Science.gov (United States)

    Bhattacharya, Purba; Mohanty, Bedangadas; Mukhopadhyay, Supratik; Majumdar, Nayana; da Luz, Hugo Natal

    2017-10-01

    Time Projection Chamber (TPC) has been chosen as the main tracking system in several high-flux and high repetition rate experiments. These include on-going experiments such as ALICE and future experiments such as PANDA at FAIR and ILC. Different R&D activities were carried out on the adoption of Gas Electron Multiplier (GEM) as the gas amplification stage of the ALICE-TPC upgrade version. The requirement of low ion feedback has been established through these activities. Low ion feedback minimizes distortions due to space charge and maintains the necessary values of detector gain and energy resolution. In the present work, Garfield simulation framework has been used to study the related physical processes occurring within single, triple and quadruple GEM detectors. Ion backflow and electron transmission of quadruple GEMs, made up of foils with different hole pitch under different electromagnetic field configurations (the projected solutions for the ALICE TPC) have been studied. Finally a new triple GEM detector configuration with low ion backflow fraction and good electron transmission properties has been proposed as a simpler GEM-based alternative suitable for TPCs for future collider experiments.

  4. Detectors for alpha particles and X-rays operating in ambient air in pulse counting mode and/or with gas amplification

    CERN Document Server

    Charpak, Georges; Breuil, P; Peskov, Vladimir

    2008-01-01

    Ionization chambers working in ambient air in current detection mode are widely used in several applications such as smoke detection, dosimetry, therapeutic beam monitoring and cetera. The aim of this work was to investigate if gaseous detectors can operate in ambient air in pulse counting mode as well as with gas amplification. . To investigate the feasibility of this method two types of open- end gaseous detectors were build and successfully tested. The first one was a single wire or multiwire cylindrical geometry detector operating in pulse mode at a gas gain of 1. The second type alpha detector was an innovative GEM-like detector with resistive electrodes operating in air in avalanche mode at high gas gains (up to 10E4). A detailed comparison between these two detectors is given as well as comparison with the commercially available alpha detectors. The main advantages of gaseous detectors operating in air in a pulse detection mode are their simplicity, low cost and high sensitivity. One of the possible ap...

  5. Canada's Northwest Territories : Can gas and gems bring sustained growth to the North?

    International Nuclear Information System (INIS)

    Burleton, D.

    2003-01-01

    Canada's fastest growing regional market is the Northwest Territories (NWT) due to the significant amount of private-sector investment injected into exploration and development of natural gas and diamonds. The proposed development of a pipeline from the Mackenzie Delta to southern markets has captured attention, and its indirect benefits could provide a huge payoff for the NWT. Other sectors such as hydro-electricity, telecommunication services and tourism are expected to benefit. Important questions must be answered by policy makers, such as the likelihood of sustaining the economic boom and keeping the gains in the NWT rather than flowing south. The author argued that the economic boom will have staying power, since price conditions have improved, and the discovery of diamonds has attracted diamond development activities. Aboriginals are increasingly seeking participation in resource development. Five major challenges were identified: diversification beyond natural resources, infrastructure, labour shortages, impact on the environment, and high costs of living and doing business coupled with concerns about regulation. It was suggested that although the federal government is helping, the NWT government must take control of its own destiny. Resource royalties are not sufficient, and existing tools to create increased fiscal room must be investigated. Debt financing must be addressed to solve some near-term challenges. In addition, the private sector must be engaged. refs., tabs., figs

  6. Four-Wave Optical Parametric Amplification in a Raman-Active Gas

    Directory of Open Access Journals (Sweden)

    Yuichiro Kida

    2015-08-01

    Full Text Available Four-wave optical parametric amplification (FWOPA in a Raman-active medium is experimentally investigated by use of an air-filled hollow fiber. A femtosecond pump pulse shorter than the period of molecular motion excites the coherent molecular motion of the Raman-active molecules during the parametric amplification of a signal pulse. The excited coherent motion modulates the frequency of the signal pulse during the parametric amplification, and shifts it to lower frequencies. The magnitude of the frequency redshift depends on the pump intensity, resulting in intensity-dependent spectral characteristics that are different from those in the FWOPA induced in a noble-gas-filled hollow fiber.

  7. Graphics gems

    CERN Document Server

    Heckbert, Paul S

    1994-01-01

    Graphics Gems IV contains practical techniques for 2D and 3D modeling, animation, rendering, and image processing. The book presents articles on polygons and polyhedral; a mix of formulas, optimized algorithms, and tutorial information on the geometry of 2D, 3D, and n-D space; transformations; and parametric curves and surfaces. The text also includes articles on ray tracing; shading 3D models; and frame buffer techniques. Articles on image processing; algorithms for graphical layout; basic interpolation methods; and subroutine libraries for vector and matrix algebra are also demonstrated. Com

  8. Progress on large area GEMs (VCI 2010)

    CERN Document Server

    Villa, Marco; Alfonsi, Matteo; Brock, Ian; Croci, Gabriele; David, Eric; de Oliveira, Rui; Ropelewski, Leszek; Taureg, Hans; van Stenis, Miranda

    2011-01-01

    The Gas Electron Multiplier (GEM) manufacturing technique has recently evolved to allow the production of large area GEMs. A novel approach based on single mask photolithography eliminates the mask alignment issue, which limits the dimensions in the traditional double mask process. Moreover, a splicing technique overcomes the limited width of the raw material. Stretching and handling issues in large area GEMs have also been addressed. Using the new improvements it was possible to build a prototype triple-GEM detector of ~ 2000 cm2 active area, aimed at an application for the TOTEM T1 upgrade. Further refinements of the single mask technique give great control over the shape of the GEM holes and the size of the rims, which can be tuned as needed. In this framework, simulation studies can help to understand the GEM behavior depending on the hole shape.

  9. GEM-AQ, an on-line global multiscale chemical weather modelling system: model description and evaluation of gas phase chemistry processes

    Directory of Open Access Journals (Sweden)

    J. W. Kaminski

    2008-06-01

    Full Text Available Tropospheric chemistry and air quality processes were implemented on-line in the Global Environmental Multiscale weather prediction model. The integrated model, GEM-AQ, was developed as a platform to investigate chemical weather at scales from global to urban. The current chemical mechanism is comprised of 50 gas-phase species, 116 chemical and 19 photolysis reactions, and is complemented by a sectional aerosol module with 5 aerosols types. All tracers are advected using the semi-Lagrangian scheme native to GEM. The vertical transport includes parameterized subgrid-scale turbulence and large scale deep convection. Dry deposition is included as a flux boundary condition in the vertical diffusion equation. Wet deposition of gas-phase species is treated in a simplified way, and only below-cloud scavenging is considered. The emissions used include yearly-averaged anthropogenic, and monthly-averaged biogenic, ocean, soil, and biomass burning emission fluxes, as well as NOx from lightning. In order to evaluate the ability to simulate seasonal variations and regional distributions of trace gases such as ozone, nitrogen dioxide and carbon monoxide, the model was run for a period of five years (2001–2005 on a global uniform 1.5°×1.5° horizontal resolution domain and 28 hybrid levels extending up to 10 hPa. Model results were compared with observations from satellites, aircraft measurement campaigns and balloon sondes. We find that GEM-AQ is able to capture the spatial details of the chemical fields in the middle and lower troposphere. The modelled ozone consistently shows good agreement with observations, except over tropical oceans. The comparison of carbon monoxide and nitrogen dioxide with satellite measurements emphasizes the need for more accurate, year-specific emissions fluxes for biomass burning and anthropogenic sources. Other species also compare well with available observations.

  10. GEM Detector Performance Assessment in the BM@N Experiment

    Science.gov (United States)

    Kapishin, Mikhail; Karjavin, Vladimir; Kulish, Elena; Lenivenko, Vasilisa; Makankin, Alexander; Maksymchuk, Anna; Palichik, Vladimir; Vasiliev, Sergey

    2018-02-01

    The Gas Electron Multiplier (GEM) chambers are developed for modern purposes in the elementary particle physics. In the BM@N experiment, a GEM system is used for the reconstruction of the trajectories of the charged particles. The investigation of GEM performance (efficiency and spatial resolution) is presented.

  11. GEM Detector Performance Assessment in the BM@N Experiment

    Directory of Open Access Journals (Sweden)

    Kapishin Mikhail

    2018-01-01

    Full Text Available The Gas Electron Multiplier (GEM chambers are developed for modern purposes in the elementary particle physics. In the BM@N experiment, a GEM system is used for the reconstruction of the trajectories of the charged particles. The investigation of GEM performance (efficiency and spatial resolution is presented.

  12. A large area GEM detector

    CERN Document Server

    Duarte Pinto, Serge; Brock, Ian; Croci, Gabriele; David, Eric; de Oliveira, Rui; Pinchasik, Bat-El; Ropelewski, Leszek; Sauli, Fabio; van Stenis, Miranda

    2009-01-01

    A prototype triple GEM detector has been constructed with an area of similar to 2000 cm(2), based on foils of 66 cm x 66 cm. GEMS of such dimensions have not been made before, and innovations to the existing technology were made to build this detector. A single-mask technique overcomes the cumbersome practice of alignment of two masks, which limits the achievable lateral size. Refinement of this technique results in foils with performance similar to traditional GEMS, while lowering cost and complexity of production. In a splicing procedure, foils are glued over a narrow seam, thus obtaining a larger foil. This procedure was shown not to affect the performance of the GEMS. The seam can be as narrow as 2 mm, mechanically strong enough to withstand the necessary stretching tension, and sufficiently flat to maintain homogeneous electric fields in the gas volumes above and below the foil. These innovations should make the manufacture Of GEM foils of 1 m(2) and beyond possible. With the planned high luminosity upgr...

  13. Evaluation of a GEM and CAT-based detector for radiation therapy beam monitoring

    International Nuclear Information System (INIS)

    Brahme, A.; Danielsson, M.; Iacobaeus, C.; Ostling, J.; Peskov, V.; Wallmark, M.

    2000-01-01

    We are developing a radiation therapy beam monitor for the Karolinska Institute. This monitor will consist of two consecutive detectors confined in one gas chamber: a 'keV-photon detector', which will allow diagnostic quality visualization of the patient, and a 'MeV-photon detector', that will measure the absolute intensity of the therapy beam and its position with respect to the patient. Both detectors are based on highly radiation resistant gas and solid photon to electron converters, combined with GEMs and a CAT as amplification structures. We have performed systematic studies of the high-rate characteristics of the GEM and the CAT, as well as tested the electron transfer through these electron multipliers and various types of converters. The tests show that the GEM and the CAT satisfy all requirements for the beam monitoring system. As a result of these studies we successfully developed and tested a full section of the beam monitor equipped with a MeV-photon converter placed between the GEM and the CAT

  14. Vacuum ultraviolet light source utilizing rare gas scintillation amplification sustained by photon positive feedback

    Science.gov (United States)

    Aprile, Elena (Inventor); Chen, Danli (Inventor)

    1995-01-01

    A source of light in the vacuum ultraviolet (VUV) spectral region includes a reflective UV-sensitive photocathode supported in spaced parallel relationship with a mesh electrode within a rare gas at low pressure. A high positive potential applied to the mesh electrode creates an electric field which causes drifting of free electrons occurring between the electrodes and producing continuous VUV light output by electric field-driven scintillation amplification sustained by positive photon feedback mediated by photoemission from the photocathode. In one embodiment the lamp emits a narrow-band continuum peaked at 175 nm.

  15. Resolution studies of a GEM-based TPC

    International Nuclear Information System (INIS)

    Killenberg, M.

    2006-01-01

    Currently there are four different concept studies trying to optimise the detector for the requirements at the ILC. In three of these detector concepts a time projection chamber (TPC) is foreseen as the main tracking device. To achieve the intended spatial resolution of 100 μm, micro pattern gas detectors (MPGD) are considered for gas amplification. The two different MPGDs discussed for the ILC TPC are Micro-Mesh Gaseous Detectors (Micromegas) and Gas Electron Multiplier foils (GEMs). The current thesis shows resolution studies with a TPC prototype equipped with a triple GEM readout structure. A hodoscope made up of silicon strip sensors gives a precision reference track, allowing an unbiased measurement of the spatial resolution. High statistics measurements have been conducted at the DESY test beam facility, which provides positrons with a tunable energy between 1 GeV and 6 GeV. Using the independent measurement of the hodoscope allows systematic studies of the homogeneity of the TPC's electric field. The fluctuations of the field in the chamber's central region were found to be ΔE/E=8.10 -3 . Field distortions have been determined and corrected, reducing the remaining deviations to a level well below the spatial resolution of the TPC. One important task is to reduce the number of ions drifting back into the sensitive volume. Special GEM settings with minimised ion backdrift have been examined with respect to their influence on the spatial resolution and it was found that the spatial resolution is not degraded using these special settings. The TPC prototype has been operated in a 4 T magnetic field, provided by a superconducting solenoid located at DESY Hamburg. Again the spatial resolution measured with the ion backdrift optimised settings is compared to that achieved with nonoptimised settings. In both cases the measured resolution is approximately 130 μm. (orig.)

  16. Resolution studies of a GEM-based TPC

    Energy Technology Data Exchange (ETDEWEB)

    Killenberg, M.

    2006-12-15

    Currently there are four different concept studies trying to optimise the detector for the requirements at the ILC. In three of these detector concepts a time projection chamber (TPC) is foreseen as the main tracking device. To achieve the intended spatial resolution of 100 {mu}m, micro pattern gas detectors (MPGD) are considered for gas amplification. The two different MPGDs discussed for the ILC TPC are Micro-Mesh Gaseous Detectors (Micromegas) and Gas Electron Multiplier foils (GEMs). The current thesis shows resolution studies with a TPC prototype equipped with a triple GEM readout structure. A hodoscope made up of silicon strip sensors gives a precision reference track, allowing an unbiased measurement of the spatial resolution. High statistics measurements have been conducted at the DESY test beam facility, which provides positrons with a tunable energy between 1 GeV and 6 GeV. Using the independent measurement of the hodoscope allows systematic studies of the homogeneity of the TPC's electric field. The fluctuations of the field in the chamber's central region were found to be {delta}E/E=8.10{sup -3}. Field distortions have been determined and corrected, reducing the remaining deviations to a level well below the spatial resolution of the TPC. One important task is to reduce the number of ions drifting back into the sensitive volume. Special GEM settings with minimised ion backdrift have been examined with respect to their influence on the spatial resolution and it was found that the spatial resolution is not degraded using these special settings. The TPC prototype has been operated in a 4 T magnetic field, provided by a superconducting solenoid located at DESY Hamburg. Again the spatial resolution measured with the ion backdrift optimised settings is compared to that achieved with nonoptimised settings. In both cases the measured resolution is approximately 130 {mu}m. (orig.)

  17. Mustard gas surrogate, 2-chloroethyl ethylsulfide (2-CEES), induces centrosome amplification and aneuploidy in human and mouse cells : 2-CEES induces centrosome amplification and chromosome instability.

    Science.gov (United States)

    Bennett, Richard A; Behrens, Elizabeth; Zinn, Ashtyn; Duncheon, Christian; Lamkin, Thomas J

    2014-08-01

    Mustard gas is a simple molecule with a deadly past. First used as a chemical weapon in World War I, its simple formulation has raised concerns over its use by terrorist organizations and unstable governments. Mustard gas is a powerful vesicant and alkylating agent that causes painful blisters on epithelial surfaces and increases the incidence of cancer in those exposed. The mechanism of mustard gas toxicity and tumorigenesis is not well understood but is thought to be mediated by its ability to induce oxidative stress and DNA damage. Interestingly, several proteins that have been shown to either be targets of mustard gas or mediate mustard gas toxicity have also been shown to regulate centrosome duplication. Centrosomes are small nonmembrane-bound organelles that direct the segregation of chromosomes during mitosis through the formation of the bipolar mitotic spindle. Cells with more or less than two centrosomes during mitosis can segregate their chromosomes unequally, resulting in chromosome instability, a common phenotype of cancer cells. In our studies, we show that subtoxic levels of 2-chloroethyl ethylsulfide (2-CEES), a mustard gas analog, induce centrosome amplification and chromosome instability in cells, which may hasten the mutation rate necessary for tumorigenesis. These data may explain why those exposed to mustard gas exhibit higher incidences of cancer than unexposed individuals of the same cohort.

  18. Assessing the performance of gas collection systems in select Chinese landfills according to the LandGEM model: drawbacks and potential direction.

    Science.gov (United States)

    Sun, Yue; Yue, Dongbei; Li, Rundong; Yang, Ting; Liu, Shiliang

    2015-01-01

    In China, municipal solid waste (MSW) is primarily treated by landfilling. Landfill gas (LFG) collection effectively reduces methane emission from MSW landfills. An accurate system of LFG collection is important in landfill planning, design, and operation. However, China has not developed such systems. In this study, the efficiency of methane collection is calculated in three Chinese landfills with different collection systems (A: vertical wells for MSW before 2010; combined horizontal trenches and under-membrane pipes for MSW from 2011 onwards; B: combined horizontal trenches and vertical wells; C: vertical wells only). This efficiency was computed by dividing the quantity of methane obtained from landfill operation records by the quantity estimated based on the LandGEM model. Results show that the collection efficiencies of landfills with vertical wells and/or horizontal pipes ranged from 8.3% to 27.9%, whereas those of a system equipped with geomembrane reached 65.3%. The poor performance of the landfills was attributed to the open burning of early-stage LFG, LFG release from cracks in high-density polyethylene covers, and high levels of leachate within a landfill site. Therefore, this study proposes an integrated LFG collection system that can remove leachate and collect gas from landfills that accept waste with high moisture content.

  19. Not Your Ordinary GEM

    Science.gov (United States)

    2001-01-01

    Through Small Business Innovation Research (SBIR) funding from NASA's Stennis Space Center, Geophex devised a new design for broadband electromagnetic sensors. Geophex developed a patented sensing technology, capable not only of coastal monitoring, but also a variety of other functions, including environmental pollution characterization, groundwater contamination detection, archaeological study, and mineral detection. The new technology is offered in several of the company's products the GEM-2, GEM-2A, and the GEM-3. The Geophex products consist of two primary electromagnetic coils, which are stimulated by alternating currents that generate a magnetic field in the object targeted for investigation. GEM-2 is a handheld, lightweight, programmable, digital device. GEM-2A is an airborne version of the sensor. Suspended from a helicopter, the GEM-2A is used to search for mineral deposits and to survey large tracts of land. The GEM-3 is capable of detecting buried landmines and other active munitions. GEM-3 identifies landmines by their brand names. Because each landmine has its own unique electromagnetic response to the broad frequency band emitted by the GEM-3, bomb identification and disposal strategies are made easier.

  20. Numerical Investigation on Electron and Ion Transmission of GEM-based Detectors

    Directory of Open Access Journals (Sweden)

    Bhattacharya Purba

    2018-01-01

    Full Text Available ALICE at the LHC is planning a major upgrade of its detector systems, including the TPC, to cope with an increase of the LHC luminosity after 2018. Different R&D activities are currently concentrated on the adoption of the Gas Electron Multiplier (GEM as the gas amplification stage of the ALICE-TPC upgrade version. The major challenge is to have low ion feedback in the drift volume as well as to ensure a collection of good percentage of primary electrons in the signal generation process. In the present work, Garfield simulation framework has been adopted to numerically estimate the electron transparency and ion backflow fraction of GEM-based detectors. In this process, extensive simulations have been carried out to enrich our understanding of the complex physical processes occurring within single, triple and quadruple GEM detectors. A detailed study has been performed to observe the effect of detector geometry, field configuration and magnetic field on the above mentioned characteristics.

  1. Development of a new imaging device using a VUV scintillator and a gas photomultiplier with a μ-PICand GEM

    Czech Academy of Sciences Publication Activity Database

    Kurosawa, S.; Taniue, K.; Sekiya, H.; Kubo, H.; Ida, C.; Miuchi, K.; Tanimori, T.; Yanagida, T.; Yokota, Y.; Yoshikawa, A.; Fukuda, K.; Kawaguchi, N.; Ishizu, S.; Nakagawa, M.; Suyama, T.; Pejchal, Jan

    2012-01-01

    Roč. 7, MAR (2012), 1-9 ISSN 1748-0221 Institutional research plan: CEZ:AV0Z10100521 Keywords : photon detectors for UV * visible and IR photons (gas) * scintillators * scintillation and light emission processes Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.869, year: 2011

  2. The GEM Silicon Tracking System

    International Nuclear Information System (INIS)

    Mills, G.B.

    1993-01-01

    The GEM Collaboration has produced a baseline design for the GEM detector. The baseline design of the GEM Silicon Tracking System (STS) is discussed in this article. Mechanical and electrical engineering progress on the GEM STS is described. Results from simulations of detector performance and the implications on engineering issues are described

  3. Building a large-area GEM-based readout chamber for the upgrade of the ALICE TPC

    CERN Document Server

    Gasik, Piotr

    2016-01-01

    A large Time Projection Chamber (TPC) is the main device for tracking and charged-particle identification in the ALICE experiment at the CERN LHC. After the second long shutdown in 2019-2020, the LHC will deliver Pb beams colliding at an interaction rate up to 50 kHz, which is about a factor of 100 above the present read-out rate of the TPC. To fully exploit the LHC potential the TPC will be upgraded based on the Gas Electron Multiplier (GEM) technology. A prototype of an ALICE TPC Outer Read-Out Chamber (OROC) was equipped with twelve large-size GEM foils as amplification stage to demonstrate the feasibility of replacing the current Multi Wire Proportional Chambers with the new technology. With a total area of $\\sim$0.76 m$^2$ it is the largest GEM-based detector built to date. The GEM OROC was installed within a test field cage and commissioned with radioactive sources.

  4. The influence of inhomogeneous temperature distribution on the amplification of sound waves in non-equilibrium gas media

    Science.gov (United States)

    Suleimenov, I.; Aushev, V.; Adamov, T.; Vasiliev, I.

    Modern investigations show that the effect of acoustic and acoustic-gravity waves amplification strongly influence on the temperature balance in atmosphere. These waves may be amplified due to the transformation of energy of chemically active (or ionized) components into the energy of wave motion, i.e. the nature of the effect is the same as the amplification of sound in other non-equilibrium gas media (for example, in gas discharge plasma). Recently Jiyao Xu (1999) reported that the theory of such waves might be developed in the same way as the theory of acoustic-gravity waves. It is shown that the influence of inhomogeneous altitude distribution of temperature should be taken into account for the correct interpretation of temperature balance in the atmosphere. In other words, the self-agreed problem have to be solved: transformation of chemical energy into energy of wave motion change the vertical profile of the atmosphere temperature, but the profile of the temperature itself determine the amplification coefficient of the wave. The results of analytical solution of the problem are reported. We show that the sign of temperature gradient strongly influence on the behavior of amplified acoustic and acoustic-gravity waves. The regime of amplification is stable when the second derivative of the temperature is negative (temperature has minimum at some point). In other words the stable channel of amplification of the waves may exist, for example, in the tube when the temperature of the walls is higher than the temperature of the gas at the axe. The different instabilities appear in the opposite case when the temperature in the reference point has a maximum. In particular, it means that the amplification of acoustic waves in gas discharge tubes cannot be stable. Moreover, our results show that self-generation of acoustic-gravity in middle atmosphere due to photochemical reactions cannot be stable process too. This conclusion is in accordance with known experimental

  5. GEM-MIGAS: Charge gain characteristics for the induction gap in the 50-300 μm range

    International Nuclear Information System (INIS)

    Mir, J.A.; Conceicao, A.S.; Al-Shejni, H.Y.; Veloso, J.F.C.A.; Santos, J.M.F. dos

    2010-01-01

    A conventional gas electron multiplier with its induction gap set around 50 μm results in a two stage electron amplification device called the gas electron multiplier with micro-induction gap amplifying structure (GEM-MIGAS). We present results on the charge gain characteristics of GEM-MIGAS induction gap as a function of induction gap thickness, using the single electron response method. In the present study, the induction gap was varied between 50 and 300 μm and the GEM-MIGAS was operated in gas flow mode using He/iso-C 4 H 10 (85/15%). The charge gain response agreed well with the classical parallel plate gain formula. From the experimental data, it was possible to derive the approximate values of the ionisation potential threshold and the ionisation mean free path, which exhibits an approximately linear dependence on the induction gap thickness. The optimum gap thickness region, where the charge gain was at a maximum for a given induction voltage and where it was least sensitive to variations in the gap thickness, was found to be in the 50-70 μm range. Nevertheless, the highest charge gains, achieved before the onset of detector instabilities, were obtained with the gap thickness set between 150 and 300 μm with values reaching the 10 6 region, owing to the higher voltages that can be applied to the device.

  6. Radiation imaging with optically read out GEM-based detectors

    Science.gov (United States)

    Brunbauer, F. M.; Lupberger, M.; Oliveri, E.; Resnati, F.; Ropelewski, L.; Streli, C.; Thuiner, P.; van Stenis, M.

    2018-02-01

    Modern imaging sensors allow for high granularity optical readout of radiation detectors such as MicroPattern Gaseous Detectors (MPGDs). Taking advantage of the high signal amplification factors achievable by MPGD technologies such as Gaseous Electron Multipliers (GEMs), highly sensitive detectors can be realised and employing gas mixtures with strong scintillation yield in the visible wavelength regime, optical readout of such detectors can provide high-resolution event representations. Applications from X-ray imaging to fluoroscopy and tomography profit from the good spatial resolution of optical readout and the possibility to obtain images without the need for extensive reconstruction. Sensitivity to low-energy X-rays and energy resolution permit energy resolved imaging and material distinction in X-ray fluorescence measurements. Additionally, the low material budget of gaseous detectors and the possibility to couple scintillation light to imaging sensors via fibres or mirrors makes optically read out GEMs an ideal candidate for beam monitoring detectors in high energy physics as well as radiotherapy. We present applications and achievements of optically read out GEM-based detectors including high spatial resolution imaging and X-ray fluorescence measurements as an alternative readout approach for MPGDs. A detector concept for low intensity applications such as X-ray crystallography, which maximises detection efficiency with a thick conversion region but mitigates parallax-induced broadening is presented and beam monitoring capabilities of optical readout are explored. Augmenting high resolution 2D projections of particle tracks obtained with optical readout with timing information from fast photon detectors or transparent anodes for charge readout, 3D reconstruction of particle trajectories can be performed and permits the realisation of optically read out time projection chambers. Combining readily available high performance imaging sensors with compatible

  7. GEM applications outside high energy physics

    CERN Document Server

    Duarte Pinto, Serge

    2013-01-01

    From its invention in 1997, the Gas Electron Multiplier has been applied in nuclear and high energy physics experiments. Over time however, other applications have also exploited the favorable properties of GEMs. The use of GEMs in these applications will be explained in principle and practice. This paper reviews applications in research, beam instrumentation and homeland security. The detectors described measure neutral radiations such as photons, x-rays, gamma rays and neutrons, as well as all kinds of charged radiation. This paper provides an overview of the still expanding range of possibilities of this versatile detector concept.

  8. Simulation of the CMS GEM System

    CERN Document Server

    Sharma, Archie

    2015-01-01

    The new GE1/1 system of Gas Electron Multipiers (GEM) is going to be installed in the CMS detector in the forward region with $\\eta$ between 1.6 and 2.2 after the second long LHC shutdown. 36 super-chambers are planned to be installed in order to ensure the redundancy and robustness of the muon system in high-luminosity conditions at the LHC. A further extension to the GEM system is also considered. The simulation of the entire GEM system integrated in the common CMS reconstruction chain is a necessary part of the performed Monte Carlo studies. A dedicated parametric model based on the exhaustive standalone MC studies and experimental test beam results has been developed in order to simulate the response of the GEM system. The simulated digital readout signals are used to build the reconstructed hits in the detector planes. They have been included in the common CMS muon reconstruction algorithms. This contribution will present the developed simulation model and the importance of the gem system for the improve...

  9. Study of the spatial resolution of low-material GEM tracking detectors

    Directory of Open Access Journals (Sweden)

    Kudryavtsev V.N.

    2018-01-01

    Full Text Available The spatial resolution of GEM based tracking detectors has been simulated and measured. The simulation includes the GEANT4 based transport of high energy electrons with careful accounting for atomic relaxation processes including emission of fluorescent photons and Auger electrons and custom post-processing, including accounting for diffusion, gas amplification fluctuations, the distribution of signals on readout electrodes, electronics noise and a particular algorithm of the final coordinate calculation (center of gravity. The simulation demonstrates that a minimum of the spatial resolution of about 10 μm can be achieved with strip pitches from 250 μm to 300 μm. For larger pitches the resolution is quickly degrading reaching 80-100 μm at a pitch of 500 μm. The spatial resolution of low-material triple-GEM detectors for the DEUTRON facility at the VEPP-3 storage ring is measured at the extracted beam facility of the VEPP-4M collider. The amount of material in these detectors is reduced by etching the copper of the GEMs electrodes and using a readout structure on a thin kapton foil rather than on a glass fibre plate. The exact amount of material in one DEUTRON detector is measured by studying multiple scattering of 100 MeV electrons in it. The result of these measurements is X/X0 = 2.4×10−3 corresponding to a thickness of the copper layers of the GEM foils of 3 μm. The spatial resolution of one DEUTRON detector is measured with 500 MeV electrons and the measured value is equal to 35 ± 1 μm for orthogonal tracks.

  10. Study of the spatial resolution of low-material GEM tracking detectors

    Science.gov (United States)

    Kudryavtsev, V. N.; Maltsev, T. V.; Shekhtman, L. I.

    2018-02-01

    The spatial resolution of GEM based tracking detectors has been simulated and measured. The simulation includes the GEANT4 based transport of high energy electrons with careful accounting for atomic relaxation processes including emission of fluorescent photons and Auger electrons and custom post-processing, including accounting for diffusion, gas amplification fluctuations, the distribution of signals on readout electrodes, electronics noise and a particular algorithm of the final coordinate calculation (center of gravity). The simulation demonstrates that a minimum of the spatial resolution of about 10 μm can be achieved with strip pitches from 250 μm to 300 μm. For larger pitches the resolution is quickly degrading reaching 80-100 μm at a pitch of 500 μm. The spatial resolution of low-material triple-GEM detectors for the DEUTRON facility at the VEPP-3 storage ring is measured at the extracted beam facility of the VEPP-4M collider. The amount of material in these detectors is reduced by etching the copper of the GEMs electrodes and using a readout structure on a thin kapton foil rather than on a glass fibre plate. The exact amount of material in one DEUTRON detector is measured by studying multiple scattering of 100 MeV electrons in it. The result of these measurements is X/X0 = 2.4×10-3 corresponding to a thickness of the copper layers of the GEM foils of 3 μm. The spatial resolution of one DEUTRON detector is measured with 500 MeV electrons and the measured value is equal to 35 ± 1 μm for orthogonal tracks.

  11. Diffraction measurements with a boron-based GEM neutron detector

    Science.gov (United States)

    Croci, Gabriele; Albani, Giorgia; Cazzaniga, Carlo; Perelli Cippo, Enrico; Schooneveld, Erik; Claps, Gerardo; Cremona, Anna; Grosso, Giovanni; Muraro, Andrea; Murtas, Fabrizio; Rebai, Marica; Scherillo, Antonella; Tardocchi, Marco; Gorini, Giuseppe

    2014-07-01

    The research of reliable substitutes of 3He detectors is an important task for the affordability of new neutron scattering instrumentation for future spallation sources like the European Spallation Source. GEM (Gas Electron Multiplier)-based detectors represent a valid alternative since they can combine high-rate capability, coverage of up to 1\\ \\text{m}^{2} area and good intrinsic spatial resolution (for this detector class it can be better than 0.5 mm). The first neutron diffraction measurements performed using a borated GEM detector are reported. The detector has an active area of 10 \\times 5\\ \\text{cm}^{2} and is equipped with a borated cathode. The GEM detector was read out using the standard ISIS Data Acquisition System. The comparison with measurements performed with standard 3He detectors shows that the broadening of the peaks measured on the diffractogram obtained with the GEM is 20-30% wider than the one obtained by 3He tubes but the active area of the GEM is twice that of 3He tubes. The GEM resolution is improved if half of its active area is considered. The signal-to-background ratio of the GEM is about 1.5 to 2 times lower than that of 3He. This measurement proves that GEM detectors can be used for neutron diffraction measurements and paves the way for their use at future neutron spallation sources.

  12. Analysis of Mechanical Properties for GEM Foil

    CERN Document Server

    Chin, Yuk Ming

    2016-01-01

    In view of new assembly technique of the GEM detector; in which three foils stack is stretched to get the uniform gaps among the foils. We studied the mechanical properties of the foil material. We conditioned the samples in different environments to make them extra dry and wet. As holes are the major source of the charge amplification their deformation can effect the detector performance. Therefore in our studies we also studied at which level of the stress the holes deformation is seen. These tensile and holes deformation studies can help to optimize the stress during detector assembly.

  13. GEM photomultiplier operation in CF sub 4

    CERN Document Server

    Breskin, Amos; Chechik, R

    2002-01-01

    The properties of a 3-GEM (Gas Electron Multiplier) element photomultiplier, with a semitransparent CsI photocathode and CF sub 4 gas filling, are presented. Compared to other gas mixtures, such as CH sub 4 , Ar/CH sub 4 , Ar/N sub 2 and He/Ar/N sub 2 , CF sub 4 has superior performance: the highest gain, approaching 10 sup 7 , the fastest, 8 ns wide signal and the lowest photoelectron backscattering; the latter allows to reach photocathode quantum efficiency values approaching that in vacuum. The time resolution of the multi-GEM photomultiplier for single photoelectrons was measured to be 2 ns. These properties are of high relevance for applications in Cherenkov detectors and in tracking devices.

  14. GEM Technical Design Report

    International Nuclear Information System (INIS)

    1993-01-01

    The GEM collaboration was formed in June 1991 to develop a major detector for the SSC. The primary physics objectives of GEM are those central to the motivation for the SSC, to study high p T physics - exemplified by the search for Higgs bosons - and to search for new physics beyond the standard model. The authors present in this Technical Design Report (TDR) a detector with broad capabilities for the discovery and subsequent study of electroweak symmetry breaking, the origin of mass and flavor, and other physics requiring precise measurements of gammas, electrons, and muons - hence the name, GEM. In addition, as a design goal, they have taken care to provide the robustness needed to do the physics that requires high luminosity. Finally, good coverage and hermeticity allow the detection of missing transverse energy, E T . The GEM design emphasizes clean identification and high resolution measurement of the primary physics signatures for high p T physics. The approach is to make precise energy measurements that maximize the sensitivity to rare narrow resonances, to detect the elementary interaction products (quarks, leptons, and photons), and to build in the features required to reduce backgrounds

  15. GEM Technical Design Report

    Energy Technology Data Exchange (ETDEWEB)

    1993-07-31

    The GEM collaboration was formed in June 1991 to develop a major detector for the SSC. The primary physics objectives of GEM are those central to the motivation for the SSC, to study high p{sub T} physics - exemplified by the search for Higgs bosons - and to search for new physics beyond the standard model. The authors present in this Technical Design Report (TDR) a detector with broad capabilities for the discovery and subsequent study of electroweak symmetry breaking, the origin of mass and flavor, and other physics requiring precise measurements of gammas, electrons, and muons - hence the name, GEM. In addition, as a design goal, they have taken care to provide the robustness needed to do the physics that requires high luminosity. Finally, good coverage and hermeticity allow the detection of missing transverse energy, E{sub T}. The GEM design emphasizes clean identification and high resolution measurement of the primary physics signatures for high p{sub T} physics. The approach is to make precise energy measurements that maximize the sensitivity to rare narrow resonances, to detect the elementary interaction products (quarks, leptons, and photons), and to build in the features required to reduce backgrounds.

  16. Some Interesting Mathematical Gems

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 11; Issue 9. Some Interesting Mathematical Gems. V G Tikekar. General Article Volume 11 Issue 9 September 2006 pp 29-42 ... Author Affiliations. V G Tikekar1. c/o Thakar New Mahadwar Road Near Padmaraje School Kolhapur 416006, India.

  17. A Hidden GEM

    Science.gov (United States)

    Khan, Samia

    2012-01-01

    The internet abounds with free science education applications. But, on their own, these applications have limited capacity to teach students curricular concepts or skills. The author integrated several free web-based applications into a broader pedagogical approach called T-GEM, in which the teacher guides student investigations. In this article,…

  18. Radiation tests for a single-GEM-loaded gaseous detector

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyong Sei; Hong, Byung Sik; Park, Sung Keun [Korea University, Seoul (Korea, Republic of); Kim, Sang Yeol [NoticeKorea, Anyang (Korea, Republic of)

    2014-11-15

    We report on a systematic study of a single-gas-electron-multiplier (GEM)-loaded gaseous detector developed for precision measurements of high-energy particle beams and for dose verification in particle therapy. In the present study, a 256-channel prototype detector having an active area of 16 x 16 cm{sup 2} and operating using a continuous current-integration-mode signal-processing method was manufactured and tested with X-rays emitted from a 70-kV X-ray generator and 43-MeV protons provided by the MC50 proton cyclotron at the Korea Institute of Radiological and Medical Science(KIRAMS). The amplified detector response was measured for X-rays with an intensity of about 5 x 10{sup 6} Hz cm{sup -2}. The linearity of the detector response to the particle flux was examined and validated by using 43-MeV proton beams. The non-uniform development of the amplification for the gas electrons in space was corrected by applying a proper calibration to the channel responses of the measured beam-profile data. We conclude from the radiation tests that the detector developed in the present study will allow us to perform quality measurements of various high-energy particle beams and to apply the technology to dose-verification measurements in particle therapy.

  19. CCD readout of GEM-based neutron detectors

    CERN Document Server

    Fraga, F A F; Fetal, S T G; Fraga, M; Guérard, B; Manzini, G; Margato, L M S; Oed, A; Policarpo, Armando; Vuure, T V

    2002-01-01

    We report on the optical readout of the gas electron multiplier (GEM) operated with a gaseous mixture suitable for the detection of thermal neutrons: sup 3 He-CF sub 4. A CCD system operating in the 400-1000 nm band was used to collect the light. Spectroscopic data on the visible and NIR scintillation of He-CF sub 4 are presented. Images of the tracks of the proton and triton recorded with a triple GEM detector are also shown.

  20. Live event reconstruction in an optically read out GEM-based TPC

    Science.gov (United States)

    Brunbauer, F. M.; Galgóczi, G.; Gonzalez Diaz, D.; Oliveri, E.; Resnati, F.; Ropelewski, L.; Streli, C.; Thuiner, P.; van Stenis, M.

    2018-04-01

    Combining strong signal amplification made possible by Gaseous Electron Multipliers (GEMs) with the high spatial resolution provided by optical readout, highly performing radiation detectors can be realized. An optically read out GEM-based Time Projection Chamber (TPC) is presented. The device permits 3D track reconstruction by combining the 2D projections obtained with a CCD camera with timing information from a photomultiplier tube. Owing to the intuitive 2D representation of the tracks in the images and to automated control, data acquisition and event reconstruction algorithms, the optically read out TPC permits live display of reconstructed tracks in three dimensions. An Ar/CF4 (80/20%) gas mixture was used to maximize scintillation yield in the visible wavelength region matching the quantum efficiency of the camera. The device is integrated in a UHV-grade vessel allowing for precise control of the gas composition and purity. Long term studies in sealed mode operation revealed a minor decrease in the scintillation light intensity.

  1. New Approach for 2D Readout of GEM Detectors

    International Nuclear Information System (INIS)

    Hasell, Douglas K.

    2011-01-01

    Detectors based on Gas Electron Multiplication (GEM) technology are becoming more and more widely used in nuclear and high energy physics and are being applied in astronomy, medical physics, industry, and homeland security. GEM detectors are thin, low mass, insensitive to magnetic fields, and can currently provide position resolutions down to ∼50 microns. However, the designs for reconstructing the position, in two dimensions (2D), of the charged particles striking a GEM detector are often complicated to fabricate and expensive. The objective of this proposal is to investigate a simpler procedure for producing the two dimensional readout layer of GEM detectors using readily available printed circuit board technology which can be tailored to the detector requirements. We will use the established GEM laboratory and facilities at M.I.T. currently employed in developing GEM detectors for the STAR forward tracking upgrade to simplify the testing and evaluation of the new 2D readout designs. If this new design proves successful it will benefit future nuclear and high energy physics experiments already being planned and will similarly extend and simplify the application of GEM technology to other branches of science, medicine, and industry. These benefits would be not only in lower costs for fabrication but also it increased flexibility for design and application.

  2. Ion space-charge effects in multi-GEM detectors: challenges and possible solutions for future applications

    CERN Document Server

    AUTHOR|(CDS)2079251; Streli, Christina

    Gaseous Electron Multiplier (GEM) detectors are well known both for stable operation under irradiation with high particle fluxes and high achievable effective gains. The aim of this thesis is two-fold: to investigate the limits of GEM detector operation due to space-charge effects, and to develop a means to reduce the magnitude of the observed effects and thus extend those limitations. The first part of the thesis presents a comprehensive study of the intrinsic limits of triple-GEM detectors under exposure to very high fluxes of soft X-rays or operation at very large effective gains. The behaviour of the effective gain, ion back-flow and the pulse-height spectra is explained in terms of the movement and accumulation of positive ions throughout the detector volume, resulting in distortions of the transfer and amplification fields. Numerical computations, and measurements on double-stage and single-stage detectors confirm the model describing the observed effects. Discussions on ways to extend the limits of gas...

  3. Complete Tem-Tomography: 3D Structure of Gems Cluster

    Science.gov (United States)

    Matsuno, J.; Miyake, A.; Tsuchiyama, A.; Messenger, S.; Nakamura-Messenger, K.

    2015-01-01

    GEMS (glass with embedded metal and sulfide) grains in interplanetary dust particles (IDPs) are considered to be one of the ubiquitous and fundamental building blocks of solids in the Solar System. They have been considered to be interstellar silicate dust that survived various metamorphism or alteration processes in the protoplanetary disk but the elemental and isotopic composition measurements suggest that most of them have been formed in the protoplanetary disk as condensates from high temperature gas. This formation model is also supported by the formation of GEMS-like grains with respect to the size, mineral assemblage, texture and infrared spectrum by condensation experiments from mean GEMS composition materials. Previous GEMS studies were performed only with 2D observation by transmission electron microscopy (TEM) or scanning TEM (STEM). However, the 3D shape and structure of GEMS grains and the spatial distribution of Fe/FeS's has critical information about their formation and origin. Recently, the 3D structure of GEMS grains in ultrathin sections of cluster IDPs was revealed by electron tomography using a TEM/STEM (JEM-2100F, JEOL). However, CT images of thin sections mounted on Cu grids acquired by conventional TEM-tomography are limited to low tilt angles (e. g., less than absolute value of 75 deg. In fact, previous 3D TEM observations of GEMS were affected by some artifacts related to the limited tilt range in the TEM used. Complete tomographic images should be acquired by rotating the sample tilt angle over a range of more than absolute value of 80 deg otherwise the CT images lose their correct structures. In order to constrain the origin and formation process of GEMS grains more clearly, we performed complete electron tomography for GEMS grains. Here we report the sample preparation method we have developed for this study, and the preliminary results.

  4. Progress in the development of photosensitive GEMs with resistive electrodes manufactured by a screen printing technology

    CERN Document Server

    Peskov, V; Nappi, E; Oliveira, R; Paic, G; Pietropaolo, F; Picchi, P

    2009-01-01

    An innovative photosensitive gaseous detector, consisting of a GEM-like amplification structure with double-layered electrodes (instead of commonly used metallic ones) coated with a CsI reflective photocathode, is described. In one of our latest designs, the inner electrode consists of a metallic grid and the outer one is made of resistive strips; the latter are manufactured by a screen-printing technology on the top of the metallic strips's grid The inner metallic grid is used for 2-D position measurements whereas the resistive layer provides an efficient spark-protected operation at high gains close to the breakdown limit. Detectors with active areas of 10×10 and 10×20 cm2 were tested under various conditions including the operation in photosensitive gas mixtures containing ethylferrocene or TMAE vapors. The new technique could have many applications requiring robust and reliable large-area detectors for UV visualization, as for example, in Cherenkov imaging devices.

  5. Graphics Gems III IBM version

    CERN Document Server

    Kirk, David

    1994-01-01

    This sequel to Graphics Gems (Academic Press, 1990), and Graphics Gems II (Academic Press, 1991) is a practical collection of computer graphics programming tools and techniques. Graphics Gems III contains a larger percentage of gems related to modeling and rendering, particularly lighting and shading. This new edition also covers image processing, numerical and programming techniques, modeling and transformations, 2D and 3D geometry and algorithms,ray tracing and radiosity, rendering, and more clever new tools and tricks for graphics programming. Volume III also includes a

  6. Graphics gems V (Macintosh version)

    CERN Document Server

    Paeth, Alan W

    1995-01-01

    Graphics Gems V is the newest volume in The Graphics Gems Series. It is intended to provide the graphics community with a set of practical tools for implementing new ideas and techniques, and to offer working solutions to real programming problems. These tools are written by a wide variety of graphics programmers from industry, academia, and research. The books in the series have become essential, time-saving tools for many programmers.Latest collection of graphics tips in The Graphics Gems Series written by the leading programmers in the field.Contains over 50 new gems displaying some of t

  7. Graphics gems II

    CERN Document Server

    Arvo, James

    1991-01-01

    Graphics Gems II is a collection of articles shared by a diverse group of people that reflect ideas and approaches in graphics programming which can benefit other computer graphics programmers.This volume presents techniques for doing well-known graphics operations faster or easier. The book contains chapters devoted to topics on two-dimensional and three-dimensional geometry and algorithms, image processing, frame buffer techniques, and ray tracing techniques. The radiosity approach, matrix techniques, and numerical and programming techniques are likewise discussed.Graphics artists and comput

  8. Development and characterization of micro-pattern gas detectors for intense beams of hadrons

    International Nuclear Information System (INIS)

    Vandenbroucke, Maxence

    2012-01-01

    This thesis work is dedicated to the design, development and characterization of Micro-Pattern Gas Detectors. The performances of a Time Projection Chamber (TPC) equipped with a triple Gas Electron Multiplier (GEM) amplification structure are reported. The intrinsic ion backflow suppression of GEM foils drastically reduces the space charge produced by wire readout in traditional TPC. The GEM solution allows the operation of a TPC at much higher event rate. The second part of this thesis describes the development of a 40 x 40 cm 2 Micromegas detector with a highly segmented central area. A reduction of discharges compared to conventional Micromegas detectors is needed for stable operation in intense beams of hadrons. Spark reduction technologies have been successfully studied and results are presented.

  9. Development and characterization of micro-pattern gas detectors for intense beams of hadrons

    Energy Technology Data Exchange (ETDEWEB)

    Vandenbroucke, Maxence

    2012-07-02

    This thesis work is dedicated to the design, development and characterization of Micro-Pattern Gas Detectors. The performances of a Time Projection Chamber (TPC) equipped with a triple Gas Electron Multiplier (GEM) amplification structure are reported. The intrinsic ion backflow suppression of GEM foils drastically reduces the space charge produced by wire readout in traditional TPC. The GEM solution allows the operation of a TPC at much higher event rate. The second part of this thesis describes the development of a 40 x 40 cm{sup 2} Micromegas detector with a highly segmented central area. A reduction of discharges compared to conventional Micromegas detectors is needed for stable operation in intense beams of hadrons. Spark reduction technologies have been successfully studied and results are presented.

  10. Investigations on Important Properties of the 10 cm x 10 cm GEM Prototype

    CERN Document Server

    Saenboonruang, Kiadtisak; Kulasri, Kittipong; Ritthirong, Anawat

    2015-01-01

    The Gas Electron Multiplier (GEM) detector is one of promising particle and radiation detectors that has been improved greatly from previous gas detectors. The improvement includes better spatial resolutions, higher detection rate capabilities, and flexibilities in designs. In particular, the 10 cm x 10 cm GEM prototype is designed and provided by the Gas Detectors Development group (GDD) at CERN, Switzerland. With its simplicity in operations and designs, while still maintaining high qualities, the GEM prototype is suitable for both start-up and advanced researches. This article aims to report the investigations on some important properties of the 10 cm x 10 cm GEM detector using current measurement and signal counting. Results have shown that gains of the GEM prototype exponentially increase as voltage supplied to the detector increases, while the detector reaches full efficiency (plateau region) when the voltage is greater than 4100 V. In terms of signal sharing between X and Y strips of the readout, X str...

  11. Game programming gems

    CERN Document Server

    DeLoura, Mark

    2000-01-01

    For the countless tasks involved in creating a game engine there are an equal number of possible solutions. But instead of spending hours and hours trying to develop your own answers, now you can find out how the pros do it! Game Programming Gems is a hands-on, comprehensive resource packed with a variety of game programming algorithms written by experts from the game industry and edited by Mark DeLoura, former software engineering lead for Nintendo of America, Inc. and now the newly appointed editor-in-chief of Game Developer magazine. From animation and artificial intelligence to Z-buffering, lighting calculations, weather effects, curved surfaces, mutliple layer Internet gaming, to music and sound effects, all of the major techniques needed to develop a competitive game engine are covered. Game Programming Gems is written in a style accessible to individuals with a range of expertise levels. All of the source code for each algorithm is included and can be used by advanced programmers immediately. For aspir...

  12. irradiated gem stones

    International Nuclear Information System (INIS)

    Salama, S.S.M

    2006-01-01

    gem stones are those stones which have beauty that can be based on its color, transparency, brilliance (degree to which light is scattered) and the crystalline perfection (no minerals or other inclusions). topaz AL 2 SiO 4 (F,OH) 2 Aluminum fluoro-hydroxyl -silicate, it belongs to class silicates and subclass cyclo silicates and it is used mainly as gemstones, it is most common irradiated gem on the market. high energy such as neutrons, have enough energy to produce color centres .irradiation is most often carried out in nuclear reactors (high-energy neutrons). irradiation of topaz in the egyptian research reactor (ETRR-2) by neutrons changes its cloudy white color to a reddish pink which could be changed to blue by heating. nuclear reactions inside the irradiated stones produce radioisotopes. resulting to residual radioactivity. residual radioactivity is potentially a problem;therefore stones have to be stored in storage for a period of time to reduce the residual radioactivity aiming to reach the safety level of transportation. the storage time of the stones is dependent on trace element concentrations connected with their life-times in topaz . therefore, inspection of the trace elements in the stones and their half-life times are essential before irradiation

  13. First proof of topological signature in high pressure xenon gas with electroluminescence amplification

    CERN Document Server

    Ferrario, P.; López-March, N.; Gómez-Cadenas, J.J.; Álvarez, V.; Azevedo, C.D.R.; Borges, F.I.G.; Cárcel, S.; Cebrián, S.; Cervera, A.; Conde, C.A.N.; Dafni, T.; Díaz, J.; Diesburg, M.; Esteve, R.; Fernandes, L.M.P.; Ferreira, A.L.; Freitas, E.D.C.; Gehman, V.M.; Goldschmidt, A.; González-Díaz, D.; Gutiérrez, R.M.; Hauptman, J.; Henriques, C.A.O.; Hernando Morata, J.A.; Irastorza, I.G.; Labarga, L.; Lebrun, P.; Liubarsky, I.; Lorca, D.; Losada, M.; Luzón, G.; Marí, A.; Martín-Albo, J.; Martínez-Lema, G.; Martínez, A.; Miller, T.; Monrabal, F.; Monserrate, M.; Monteiro, C.M.B.; Mora, F.J.; Moutinho, L.M.; Muñoz Vidal, J.; Nebot-Guinot, M.; Novella, P.; Nygren, D.; Para, A.; Pérez, J.; Pérez Aparicio, J.L.; Querol, M.; Renner, J.; Ripoll, L.; Rodríguez, J.; Santos, F.P.; dos Santos, J.M.F.; Serra, L.; Shuman, D.; Simón, A.; Sofka, C.; Sorel, M.; Toledo, J.F.; Torrent, J.; Tsamalaidze, Z.; Veloso, J.F.C.A.; Villar, J.A.; Webb, R.; White, J.T.; Yahlali, N.; Yepes-Ramírez, H.

    2016-01-01

    The NEXT experiment aims to observe the neutrinoless double beta decay of xenon in a high-pressure Xe136 gas TPC using electroluminescence (EL) to amplify the signal from ionization. One of the main advantages of this technology is the possibility to reconstruct the topology of events with energies close to Qbb. This paper presents the first demonstration that the topology provides extra handles to reject background events using data obtained with the NEXT-DEMO prototype. Single electrons resulting from the interactions of Na22 1275 keV gammas and electron-positron pairs produced by conversions of gammas from the Th228 decay chain were used to represent the background and the signal in a double beta decay. These data were used to develop algorithms for the reconstruction of tracks and the identification of the energy deposited at the end-points, providing an extra background rejection factor of 24.3 +- 1.4 (stat.)%, while maintaining an efficiency of 66.7 +- 0.6 (stat.)% for signal events.

  14. Mexican gems as thermoluminescent dosimeters

    International Nuclear Information System (INIS)

    Azorin N, J.

    1979-01-01

    The possibility of using naturally ocurring mexican gems as thermoluminescent dosimeters (TLD) was investigated. Twelve types of gems were irradiated with X and gamma rays in order to determinate their dosimetric properties. Three of these gems showed favorable thermoluminescent characteristics compared with commercial thermoluminescent dosimeters. The plots of their thermoluminescent response as a function of gamma dose are straight lines on full log paper in the dose range 10 -2 to 10 2 Gy. The energy dependence is very strong to low energies of the radiation. Their fading was found to be about 5%/yr. and they may be annealed as reused without loss in sensitivity. Therefore, these gems can be used as X and gamma radiation dosimeters. (author)

  15. A triple GEM detector with two-dimensional readout

    International Nuclear Information System (INIS)

    Ziegler, M.; Sievers, P.; Straumann, U.

    2001-01-01

    For the LHCb experiment a micropattern gas detector has been proposed as a possible technology for the inner tracking. A prototype triple GEM detector was built for this purpose. Here, the performance of this detector in a hadronic beam is presented

  16. Characterization of a hybrid GEM-Micromegas detector with respect to its application in a continuously read out TPC

    Science.gov (United States)

    Ratza, Viktor; Ball, Markus; Liebtrau, M.; Ketzer, Bernhard

    2018-02-01

    In the context of the upgrade of the LHC during the second long shutdown the interaction rate of the ALICE experiment will be increased up to 50 kHz for Pb-Pb collisions. As a consequence, a continuous read-out of the Time Projection Chamber (TPC) will be required. To keep the space-charge distortions at a manageable size, the ion backflow of the charge amplification system has to be significantly reduced. At the same time an excellent detector performance and stability of the system has to be maintained. A solution with four Gaseous Electron Multipliers (GEMs) has been adopted as baseline solution for the upgraded chambers. As an alternative approach a hybrid GEM-Micromegas detector consisting of one Micromegas (MM) and two GEMs has been investigated. The recent results of the study of the hybrid GEM-Micromegas detector will be presented and compared to measurements with four GEM foils.

  17. A triple-GEM detector for high-rate particle triggering

    Energy Technology Data Exchange (ETDEWEB)

    Alfonsi, M.; Bencivenni, G.; Simone, P. de; Murtas, F.; Poli Lener, M.; Bonivento, W. E-mail: walter.bonivento@cern.ch; Cardini, A.; Deplano, C.; Pinci, D.; Raspino, D.; Saitta, B

    2004-06-01

    We show that adding CF{sub 4} to the standard Ar/CO{sub 2} gas mixture allows to substantially improve the time resolution of triple-GEM detectors. In this paper we discuss measurements of time resolution, discharge probability per incident charged particle and pad multiplicity of a triple-GEM detector with pad readout, with new gas mixtures with CF{sub 4} and isobutane. Results for detectors with GEM foil size of both 10x10 cm{sup 2} and 20x24 cm{sup 2} are presented.

  18. Readout of TPC Tracking Chambers with GEMs and Pixel Chip

    Energy Technology Data Exchange (ETDEWEB)

    Kadyk, John; Kim, T.; Freytsis, M.; Button-Shafer, J.; Kadyk, J.; Vahsen, S.E.; Wenzel, W.A.

    2007-12-21

    Two layers of GEMs and the ATLAS Pixel Chip, FEI3, have been combined and tested as a prototype for Time Projection Chamber (TPC) readout at the International Linear Collider (ILC). The double-layer GEM system amplifies charge with gain sufficient to detect all track ionization. The suitability of three gas mixtures for this application was investigated, and gain measurements are presented. A large sample of cosmic ray tracks was reconstructed in 3D by using the simultaneous timing and 2D spatial information from the pixel chip. The chip provides pixel charge measurement as well as timing. These results demonstrate that a double GEM and pixel combination, with a suitably modified pixel ASIC, could meet the stringent readout requirements of the ILC.

  19. BoNuS: Development and Use of a Radial TPC using Cylindrical GEMs

    Energy Technology Data Exchange (ETDEWEB)

    Howard Fenker; Nathan Baillie; Peter Bradshaw; S. Bultmann; Stephen Bueltmann; Volker Burkert; Michael Christy; Gail Dodge; Dipangkar Dutta; Rolf Ent; Josh Evans; Robert Fersch; Kevin Giovanetti; Keith Griffioen; Mikayel Ispiryan; Chandana Jayalath; Narbe Kalantarians; Cynthia Keppel; Sebastian Kuhn; Gabriel Niculescu; Maria-Ioana Niculescu; Svyatoslav Tkachenko; Vladas Tvaskis; Jixie Zhang

    2007-11-28

    To provide new access to information about nucleon structure from electron-neutron interactions, a specialized aystem of target and detector was developed at Jefferson Lab. It allows identification and measurement of spectator protons produced in e X scattering events. The detector is a radial time-projection chamber optimized for the acceptance of low-momentum protons. Gas gain is provided by three cascaded curved Gas Electron Multipliers (GEMs), the first application of GEMs in any configuration other than flat.

  20. Design and creating model and interactive presentation of GEM for Microcosm Exhibition

    CERN Document Server

    Lakdee, Natthaphop

    2017-01-01

    GEM or Gas Electron Multiplier is the newer and easier way to amplify electron signal than conventional CSS. It was first created by Fabio Sauli at CERN in 1997 and was developed to get better efficiency over time. Right now, it was brought to use in many detector stations at CERN. To make GEM more publicly known, one of the ways is show in Microcosm Exhibition which is always visited by people from around the world everyday, so my main project as summer student is to design and create the model and interactive presentation which make GEM interesting and easy to understand by ordinary people.

  1. GEM-based gaseous photomultipliers for UV and visible photon imaging

    International Nuclear Information System (INIS)

    Moermann, D.; Balcerzyk, M.; Breskin, A.; Chechik, R.; Singh, B.K.; Buzulutskov, A.

    2003-01-01

    We present the current status of our research on GEM-based gaseous photomultipliers. Detectors combining multi-GEM electron multipliers with semi-transparent and reflective photocathodes are discussed. We present recent progress in extending the sensitivity of these detectors into the visible range. We demonstrate the long-term stability of an argon-sealed bi-alkali photo-diode and provide preliminary results of a gas-sealed Kapton-GEM detector with a bi-alkali photocathode. The problem of ion-induced secondary electron emission is addressed

  2. Progress on large area GEMs

    CERN Document Server

    Pinto, Serge Duarte; Alfonsi, Matteo; Brock, Ian; Croci, Gabriele; David, Eric; De Oliveira, Rui; Ropelewski, Leszek; van Stenis, Miranda

    2009-01-01

    In 2008, a triple GEM detector prototype with an area of ~2000 cm2 has been constructed, based on foils of 66*66 cm. GEMs of such dimensions had not been made before, and innovations to the existing technology were introduced to build this detector. This paper discusses these innovations and presents further work on large area GEM development. A single-mask technique overcomes the cumbersome practice of alignment of two masks, which limits the achievable lateral size. The holes obtained with this technique are conical, and have a so-called rim, a small insulating clearance around the hole in the substrate. Further refinements of this technique allow greater control over the shape of holes and the size of rims. Also, an improvement in homogeneity over large areas is expected. Simulation studies have been done to examine the effect of hole shape on the behavior of GEMs. Such studies can help understanding how to use new enhancements of the technique to optimize performance. Many potential applications for large...

  3. GEM - The Global Earthquake Model

    Science.gov (United States)

    Smolka, A.

    2009-04-01

    Over 500,000 people died in the last decade due to earthquakes and tsunamis, mostly in the developing world, where the risk is increasing due to rapid population growth. In many seismic regions, no hazard and risk models exist, and even where models do exist, they are intelligible only by experts, or available only for commercial purposes. The Global Earthquake Model (GEM) answers the need for an openly accessible risk management tool. GEM is an internationally sanctioned public private partnership initiated by the Organisation for Economic Cooperation and Development (OECD) which will establish an authoritative standard for calculating and communicating earthquake hazard and risk, and will be designed to serve as the critical instrument to support decisions and actions that reduce earthquake losses worldwide. GEM will integrate developments on the forefront of scientific and engineering knowledge of earthquakes, at global, regional and local scale. The work is organized in three modules: hazard, risk, and socio-economic impact. The hazard module calculates probabilities of earthquake occurrence and resulting shaking at any given location. The risk module calculates fatalities, injuries, and damage based on expected shaking, building vulnerability, and the distribution of population and of exposed values and facilities. The socio-economic impact module delivers tools for making educated decisions to mitigate and manage risk. GEM will be a versatile online tool, with open source code and a map-based graphical interface. The underlying data will be open wherever possible, and its modular input and output will be adapted to multiple user groups: scientists and engineers, risk managers and decision makers in the public and private sectors, and the public-at- large. GEM will be the first global model for seismic risk assessment at a national and regional scale, and aims to achieve broad scientific participation and independence. Its development will occur in a

  4. The gain in Thick GEM multipliers and its time-evolution

    CERN Document Server

    Alexeev, M; Bradamante, F; Bressan, A; Buechele, M; Chiosso, M; Ciliberti, P; Dalla Torre, S; Dasgupta, S; Denisov, O; Duic, V; Finger, M; Finger Jr, M; Fischer, H; Gobbo, B; Gregori, M; Herrmann, F; Koenigsmann, K; Levorato, S; Maggiora, A; Makke, N; Martin, A; Menon, G; Novakova, K; Novy, J; Panzieri, D; Pereira, F A; Santos, C A; Sbrizzai, G; Schiavon, P; Schopferer, S; Slunecka, M; Sozzi, F; Steiger, L; Sulc, M; Takekawa, S; Tessarotto, F; Veloso, J F C A

    2016-01-01

    In the context of a project to upgrade the gas photon detectors of COMPASS RICH-1, we have performed an R&D programme aimed to develop photon detectors based on multi-layer arrangements of thick GEM electron multipliers coupled to a CsI photoconverter. For this purpose, thick GEMs have been characterised in detail including the gain performance, its dependance on the geometrical parameters and its time-evolution, a feature exhibited by the gas detectors with open insulator surfaces. The variation due to this evolution drammatically depends on the parameters themselves. In the present article we summarise the outcomes of the studies dedicated to the thick GEM gain and its evolution versus time. We also include a qualitative model which accounts for the peculiar details of the observed thick GEM gain time-evolution.

  5. CMS Technical Design Report for the Muon Endcap GEM Upgrade

    CERN Document Server

    AUTHOR|(CDS)2108476; Safonov, A; Sharma, A; Tytgat, M; CERN. Geneva. The LHC experiments Committee; LHCC

    2015-01-01

    This report describes both the technical design and the expected performance of the Phase-II upgrade, using Gas Electron Multiplier (GEM) detectors, of the first endcap station of the CMS muon system. The upgrade is targeted for the second long shutdown of the CERN LHC and is designed to improve the muon trigger and tracking performance at high luminosity. The GEM detectors will add redundancy to the muon system in the 1.6 < |η| < 2.2 pseudorapidity region, where the amount of detection layers is lowest while the background rates are highest and the bending of the muon trajectories due to the CMS magnetic field is small. GEM detectors have been identified as a suitable technology to operate in the high radiation environment present in that region. The first muon endcap station will be instrumented with a double layer of triple-GEM chambers in the 1.6 < |η| < 2.2 region. The detector front-end electronics uses the custom designed VFAT3 chip to provide both fast input for the level-1 muon trigger ...

  6. GEM Foil Quality Assurance For The ALICE TPC Upgrade

    Science.gov (United States)

    Brücken, Erik; Hildén, Timo

    2018-02-01

    The ALICE (A Large Ion Collider Experiment) experiment at the Large Hadron Collider (LHC) at CERN is dedicated to heavy ion physics to explore the structure of strongly interacting matter. The Time Projection Chamber (TPC) of ALICE is a tracking detector located in the central region of the experiment. It offers excellent tracking capabilities as well as particle identification. After the second long shutdown (LS2) the LHC will run at substantially higher luminosities. To be able to increase the data acquisition rate by a factor of 100, the ALICE TPC experiment has to replace the Multi-Wire Proportional Chamber (MWPC) -based readout chambers. The MWPC are operated with gating grid that limits the rate to O(kHz). The new ReadOut Chamber (ROC) design is based on Gas Electron Multiplier (GEM) technology operating in continuous mode. The current GEM productions scheme foresees the production of more than 800 GEM foils of different types. To fulfill the requirements on the performance of the GEM TPC readout, necessitates thorough Quality Assurance (QA) measures. The QA scheme, developed by the ALICE collaboration, will be presented in detail.

  7. GEM Foil Quality Assurance For The ALICE TPC Upgrade

    Directory of Open Access Journals (Sweden)

    Brücken Erik

    2018-01-01

    Full Text Available The ALICE (A Large Ion Collider Experiment experiment at the Large Hadron Collider (LHC at CERN is dedicated to heavy ion physics to explore the structure of strongly interacting matter. The Time Projection Chamber (TPC of ALICE is a tracking detector located in the central region of the experiment. It offers excellent tracking capabilities as well as particle identification. After the second long shutdown (LS2 the LHC will run at substantially higher luminosities. To be able to increase the data acquisition rate by a factor of 100, the ALICE TPC experiment has to replace the Multi-Wire Proportional Chamber (MWPC –based readout chambers. The MWPC are operated with gating grid that limits the rate to O(kHz. The new ReadOut Chamber (ROC design is based on Gas Electron Multiplier (GEM technology operating in continuous mode. The current GEM productions scheme foresees the production of more than 800 GEM foils of different types. To fulfill the requirements on the performance of the GEM TPC readout, necessitates thorough Quality Assurance (QA measures. The QA scheme, developed by the ALICE collaboration, will be presented in detail.

  8. Simulation of the dielectric charging-up effect in a GEM detector

    International Nuclear Information System (INIS)

    Alfonsi, M.; Croci, G.; Duarte Pinto, S.; Rocco, E.; Ropelewski, L.; Sauli, F.; Veenhof, R.; Villa, M.

    2012-01-01

    The charging up effect is well-known in detectors containing dielectric materials and it is due to electrons and ions liberated in an avalanche and collected on the dielectric surfaces. In particular in Gas Electron Multiplier (GEM) based detectors, charges can be captured by the Kapton that separates top and bottom electrodes. The collection of a substantial number of charges on the dielectric surfaces induces a modification of the field inside the GEM holes that implies important consequences on some fundamental parameters such as the electron transparency and the effective gain. The correct simulation of this effect opens new ways to the detailed study of the processes that happens in a GEM-based detector and gives the possibility to optimise the GEM geometry in order to avoid it. This paper compares results of the measurements and the simulations, with and without the introduction of the charging-up effect, of the GEM electron transparency in the case of a single GEM detector. The introduction of the charging up effect in the simulation resulted to be crucial in order to get the proper agreement with the measurements. The measurements and simulations of the GEM effective gain will be the subject of a future work.

  9. GEM operation in helium and neon at low temperatures

    Science.gov (United States)

    Buzulutskov, A.; Dodd, J.; Galea, R.; Ju, Y.; Leltchouk, M.; Rehak, P.; Tcherniatine, V.; Willis, W. J.; Bondar, A.; Pavlyuchenko, D.; Snopkov, R.; Tikhonov, Y.

    2005-08-01

    We study the performance of Gas Electron Multipliers (GEMs) in gaseous He, Ne and Ne+H 2 at temperatures in the range of 2.6-293 K. In He, at temperatures between 62 and 293 K, the triple-GEM structures often operate at rather high gains, exceeding 1000. There is an indication that this high gain is achieved by the Penning effect in the gas impurities released by outgassing. At lower temperatures, the gain-voltage characteristics are significantly modified probably due to the freeze-out of impurities. In particular, the double- and single-GEM structures can operate down to 2.6 K at gains reaching only several tens at a gas density of about 0.5 g/l; at higher densities the maximum gain drops further. In Ne, the maximum gain also drops at cryogenic temperatures. The gain drop in Ne at low temperatures can be reestablished in Penning mixtures of Ne+H 2: very high gains, exceeding 10 4, have been obtained in these mixtures at 50-60 K, at a density of 9.2 g/l corresponding to that of saturated Ne vapor near 27 K. The results obtained are relevant in the fields of two-phase He and Ne detectors for solar neutrino detection and electron avalanching at low temperatures.

  10. High-rate particle triggering with triple-GEM detector

    CERN Document Server

    Alfonsi, M; De Simone, P; Murtas, F; Poli-Lener, M; Bonivento, W; Cardini, A; Deplano, C; Raspino, D; Pinci, D

    2004-01-01

    We report the results of a systematic study of the time performance of triple-GEM detectors operated with Ar/CO//2/CF//4 and Ar/CF//4 /iso-C//4H//1//0 gas mixtures. This study and the detector development has been performed in the framework of an R&D activity on detectors for the innermost part (region R1) of the first muon station (M1) of the LHCb experiment. The use of fast gas mixtures allows to achieve a time resolution better than 5 ns (r.m.s.) and a single detector efficiency up to similar to 99% in a 20 ns time window. Discharge studies have been performed at the piM1 hadron beam facility of the Paul Scherrer Institute. Local aging properties were investigated exposing the detector to a collimated 5.9 keV X-rays beam. The whole R&D activity with different gas mixtures has been performed with small 10 multiplied by 10 cm**2 triple-GEM detector prototypes. A full size prototype (module-0) constituted by two 20 multiplied by 24 cm**2 triple-GEM detectors, equipped with front-end electronics based ...

  11. Science's gem: Diamond science 2009

    OpenAIRE

    Mainwood, A.; Newton, M. E.; Stoneham, M.

    2009-01-01

    Natural diamond has been valued for its appearance and mechanical properties for at least two thousand years. As a gem stone diamond is unsurpassed. However, scientific work, especially in the last 20 years, has demonstrated that diamond has numerous surprising properties and many unique ones. Some of the extreme properties have been known for many years, but the true scale of diamond's other highly desirable features is still only coming to light as control in the synthesis of diamond, and h...

  12. An aging study of triple GEMs in Ar-CO sub 2

    CERN Document Server

    Guirl, L; May, J; Miyamoto, J; Shipsey, I

    2002-01-01

    An aging study was performed using triple GEMs and a print circuit board (PCB) with an intense X-ray radiation source. The GEM chamber consists of three identical GEMs and a large gas gain (6000) was shared by them. The chamber and its gas circulation line was carefully cleaned and constructed with stainless steel materials. The detector was irradiated continuously about 750 h without interruption until a large amount of charge was accumulated. A single-wire counter served as a monitoring device to check the beam and ambient conditions. The quality of the Ar-CO sub 2 gas was checked by gas chromatography and no measurable amount of hydrocarbons were found. 27 mC/mm sup 2 was accumulated with no noticeable degradation and no deposit or discoloration was found in an optical check.

  13. High voltage distribution scheme for large size GEM detector

    International Nuclear Information System (INIS)

    Saini, J.; Kumar, A.; Dubey, A.K.; Negi, V.S.; Chattopadhyay, S.

    2016-01-01

    Gas Electron Multiplier (GEM) detectors will be used for Muon tracking in the Compressed Baryonic Matter (CBM) experiment at the Facility for Anti-proton Ion Research (FAIR) at Darmstadt, Germany. The sizes of the detector modules in the Muon chambers are of the order of 1 metre x 0.5 metre. For construction of these chambers, three GEM foils are used per chamber. These foils are made by two layered 50μm thin kapton foil. Each GEM foil has millions of holes on it. In such a large scale manufacturing of the foils, even after stringent quality controls, some of the holes may still have defects or defects might develop over the time with operating conditions. These defects may result in short-circuit of the entire GEM foil. A short even in a single hole will make entire foil un-usable. To reduce such occurrences, high voltage (HV) segmentation within the foils has been introduced. These segments are powered either by individual HV supply per segment or through an active HV distribution to manage such a large number of segments across the foil. Individual supplies apart from being costly, are highly complex to implement. Additionally, CBM will have high intensity of particles bombarding on the detector causing the change of resistive chain current feeding the GEM detector with the variation in the intensity. This leads to voltage fluctuations across the foil resulting in the gain variation with the particle intensity. Hence, a low cost active HV distribution is designed to take care of the above discussed issues

  14. Results and performances of X-ray imaging GEM cameras on FTU (1-D), KSTAR (2-D) and progresses of future experimental set up on W7-X and EAST Facilities

    Science.gov (United States)

    Cordella, F.; Choe, W.; Claps, G.; Gabellieri, L.; Jang, J.; Jeon, T.; Lee, S. H.; Li, E.; Pacella, D.; Romano, A.; Song, I.

    2017-10-01

    The triple Gas Electron Multiplier (GEM) is a good candidate for the observation of the plasma volume emitting X-rays photons in the energy band up to 30 keV . The GEM camera system can be simply installed outside the port of a fusion device and it's a micropattern proportional gas detector which consists of an ionization gap, where X-rays photon conversion occurs, three consecutive foils working as amplification stage and finally a dedicated printed circuit board. Its simple experimental setup can be made in different configurations with 1D or 2D imaging possibilities: perpendicular GEM camera allows a 1D emissivity profile reconstruction instead a tangential GEM camera allows a poloidal cross-section image. Moreover, they offer high sensitivity, noise free, optical flexibility (zooming and tilting, magnification 10× up to 30×), high contrast, high dynamic range (6 orders of magnitude) and good time resolution (submillisecond). In this work several experimental results already observed on the Frascati Tokamak Upgrade (FTU) and the Korean Superconducting Tokamak Advanced Research (KSTAR) devices will be presented. The perpendicular installation on FTU allows a 1D radial profile with 128 lines of sight, while thanks to the 2D tangential view of the plasma, the reconstruction of the cross section has been done on KSTAR. Between them there are dynamic and precursors of sawtooth, effects of Edge Localized Mode (ELM) in the core and possible interplay between core and edge in ELMs (high m modes), effects of plasma rotation in the core, dynamic of injected impurities in the outer part of the plasma or also impurity accumulation and localized effects of additional heating. Installation of GEM systems is planned on Wendelstein 7-X (W7-X) and the Experimental Advanced Superconducting Tokamak (EAST) also for their robustness and flexibility X-rays detection in presence of high radiative environments (neutrons and gammas). In future applications on the above mentioned

  15. Leading a successful iGEM team.

    Science.gov (United States)

    Materi, Wayne

    2012-01-01

    The International Genetically Engineered Machines (iGEM) competition allows undergraduate teams to develop projects in synthetic biology within the context of a large, international Jamboree. Organizing and managing a successful iGEM team is an exercise in advanced agile project development. While many of the principles applicable to such teams are derived from management of agile software teams, iGEM presents several unique challenges.

  16. Quality control for the first large areas of triple GEM chambers for the CMS endcaps

    CERN Document Server

    Tytgat, Michael

    2015-01-01

    The CMS GEM collaboration plans to equip the very forward muon system with triple GEM detectors that can withstand the environment of the high-luminosity LHC. This project is at the final stages of R and D and moving to production. An unprecedented large area of several 100m2 are to be instrumented with GEM detectors which will be produced in six different sites around the world. A common construction and quality control procedure is required to ensure the performance of each detector. The quality control steps will include optical inspection, cleaning and baking of all materials and parts used to build the detector, leakage current tests of the GEM foils, high voltage tests, gas leak tests of the chambers and monitoring pressure drop vs. time, gain calibration to know the optimal operation region of the detector, gain uniformity tests, and studying the efficiency, noise and tracking performance of the detectors in a cosmic stand using scintillators.

  17. Construction and performance of a micro-pattern stereo detector with two gas electron multipliers

    Energy Technology Data Exchange (ETDEWEB)

    Barvich, T.; Bluem, P.; Erdmann, M. E-mail: Martin.Erdmann@cern.ch; Fahrer, M.; Kaercher, K.; Kuehn, F.; Moermann, D.; Mueller, Th.; Neuberger, D.; Roederer, F.; Simonis, H.J.; Skiba, A.; Thuemmel, W.H.; Weiler, Th.; Weseler, S

    2002-06-11

    The construction of a micro-pattern gas detector of dimensions 40x10 cm{sup 2} is described. Two gas electron multiplier foils (GEM) provide the internal amplification stages. A two-layer readout structure was used, manufactured using the same technology as the GEM foils. The strips of each layer cross at an effective crossing angle of 6.7 deg. and have a 406 {mu}m pitch. The performance of the detector has been evaluated in a muon beam at CERN using a silicon telescope as reference system. The position resolutions of two orthogonal coordinates are measured to be 50 {mu}m and 1 mm, respectively. The muon detection efficiency for two-dimensional space points reaches 96%.

  18. A triple GEM detector with pad readout for high rate charged particle triggering

    Energy Technology Data Exchange (ETDEWEB)

    Bencivenni, G.; Felici, G.; Murtas, F.; Valente, P.; Bonivento, W. E-mail: walter.bonivento@cern.ch; Cardini, A.; Lai, A.; Pinci, D.; Saitta, B.; Bosio, C

    2002-08-11

    In this paper, results of a time performance study of triple gas electron multiplier (GEM) detectors are discussed. This study was driven by an R and D activity on detectors for the Level 0 LHCb muon trigger. However, the results presented in this paper are of more general interest, i.e. for experiments with high rate charged particle triggering. Little interest was given so far to time performance of GEM detectors. Only one group measured double GEM detector time resolution with the Ar/CO{sub 2} (70/30) gas mixture. Our study aimed at triple GEM detector optimisation for good time performance through a detailed investigation of the role played by detector geometry, electric fields and gas mixture. The results reported here, in particular when using the gas mixture Ar/CO{sub 2}/CF{sub 4} (60/20/20), considerably improve the time performance discussed in the above-mentioned paper and make the triple GEM detector a promising option for high rate charged particle triggering.

  19. GEM-based beam profile monitors for the antiproton decelerator

    CERN Document Server

    Duarte Pinto, S.; Ropelewski, L.; Spanggaard, J.; Tranquille, G.

    2012-01-01

    The new beam profile measurement for the Antiproton Decelerator (AD) at CERN is based on a single Gas Electron Multiplier (GEM) with a 2D readout structure. This detector is very light, ~0.4% X0, as required by the low energy of the antiprotons, 5.3 MeV. This overcomes the problems previously encountered with multi-wire proportional chambers (MWPC) for the same purpose, where beam interactions with the detector severely affect the obtained profiles. A prototype was installed and successfully tested in late 2010, with another five detectors now installed in the ASACUSA and AEGIS beam lines. We will provide a detailed description of the detector and discuss the results obtained. The success of these detectors in the AD makes GEM-based detectors likely candidates for upgrade of the beam profile monitors in all experimental areas at CERN. The various types of MWPC currently in use are aging and becoming increasingly difficult to maintain.

  20. A time projection chamber with GEM-based readout

    Science.gov (United States)

    Attié, David; Behnke, Ties; Bellerive, Alain; Bezshyyko, Oleg; Bhattacharya, Deb Sankar; Bhattacharya, Purba; Bhattacharya, Sudeb; Caiazza, Stefano; Colas, Paul; Lentdecker, Gilles De; Dehmelt, Klaus; Desch, Klaus; Diener, Ralf; Dixit, Madhu; Fleck, Ivor; Fujii, Keisuke; Fusayasu, Takahiro; Ganjour, Serguei; Gao, Yuanning; Gros, Philippe; Hayman, Peter; Hedberg, Vincent; Ikematsu, Katsumasa; Jönsson, Leif; Kaminski, Jochen; Kato, Yukihiro; Kawada, Shin-ichi; Killenberg, Martin; Kleinwort, Claus; Kobayashi, Makoto; Krylov, Vladyslav; Li, Bo; Li, Yulan; Lundberg, Björn; Lupberger, Michael; Majumdar, Nayana; Matsuda, Takeshi; Mehdiyev, Rashid; Mjörnmark, Ulf; Müller, Felix; Münnich, Astrid; Mukhopadhyay, Supratik; Ogawa, Tomohisa; Oskarsson, Anders; Österman, Lennart; Peterson, Daniel; Riallot, Marc; Rosemann, Christoph; Roth, Stefan; Schade, Peter; Schäfer, Oliver; Settles, Ronald Dean; Shirazi, Amir Noori; Smirnova, Oxana; Sugiyama, Akira; Takahashi, Tohru; Tian, Junping; Timmermans, Jan; Titov, Maksym; Tsionou, Dimitra; Vauth, Annika; Wang, Wenxin; Watanabe, Takashi; Werthenbach, Ulrich; Yang, Yifan; Yang, Zhenwei; Yonamine, Ryo; Zenker, Klaus; Zhang, Fan

    2017-06-01

    For the International Large Detector concept at the planned International Linear Collider, the use of time projection chambers (TPC) with micro-pattern gas detector readout as the main tracking detector is investigated. In this paper, results from a prototype TPC, placed in a 1 T solenoidal field and read out with three independent Gas Electron Multiplier (GEM) based readout modules, are reported. The TPC was exposed to a 6 GeV electron beam at the DESY II synchrotron. The efficiency for reconstructing hits, the measurement of the drift velocity, the space point resolution and the control of field inhomogeneities are presented.

  1. Methods and results for calibration and track separation of a GEM based TPC using an UV-laser

    Energy Technology Data Exchange (ETDEWEB)

    Ball, Markus

    2008-12-15

    In the last 30 years high energy physics could write an impressive story of success. Since the introduction of the Standard Model (SM), it has met every experimental test. However the final confirmation has to prove the mechanism of electroweak symmetry breaking, which could not be confirmed yet. The most favored theory, which includes the introduction of a Higgs field, could not be verified experimentally. Furthermore there is clear evidence, that the SM is only a low energy description of nature and its principles, as the SM describes only 4 % of the known matter in the universe. There are two different approaches in accelerator driven high energy physics to clarify the open questions. The Large Hadron Collider (LHC) have a good opportunity to measure some of the missing pieces with its high center of mass energy. The International Linear Collider (ILC) will then measure their parameters with high precision. To guarantee this high precision the detectors have to be able to identify every single particle and determine its properties with high accuracy. These high requirements to the single detectors as well as the interconnectivity between all detectors are summarised by the concept of particle flow (PFLOW). This means that all particles must be separable, which includes in particular the main tracking device. A possible candidate for the central tracking device is a Time Projection Chamber (TPC). In this work a TPC with Gas Electron Multipliers (GEM) as gas amplification system was used. The GEMs replace the conventional wire amplification system of the TPC. In this PhD work a method to determine the drift velocity of a TPC was developed and tested using an ultraviolet laser. To ensure a high accuracy of the method all relevant gas parameters were measured with a slow control system. Furthermore the laser was used to investigate the separation capability of nearby tracks. Therefore an existing TPC prototype, which was developed to operate in a 5 T magnet facility

  2. Methods and results for calibration and track separation of a GEM based TPC using an UV-laser

    International Nuclear Information System (INIS)

    Ball, Markus

    2008-12-01

    In the last 30 years high energy physics could write an impressive story of success. Since the introduction of the Standard Model (SM), it has met every experimental test. However the final confirmation has to prove the mechanism of electroweak symmetry breaking, which could not be confirmed yet. The most favored theory, which includes the introduction of a Higgs field, could not be verified experimentally. Furthermore there is clear evidence, that the SM is only a low energy description of nature and its principles, as the SM describes only 4 % of the known matter in the universe. There are two different approaches in accelerator driven high energy physics to clarify the open questions. The Large Hadron Collider (LHC) have a good opportunity to measure some of the missing pieces with its high center of mass energy. The International Linear Collider (ILC) will then measure their parameters with high precision. To guarantee this high precision the detectors have to be able to identify every single particle and determine its properties with high accuracy. These high requirements to the single detectors as well as the interconnectivity between all detectors are summarised by the concept of particle flow (PFLOW). This means that all particles must be separable, which includes in particular the main tracking device. A possible candidate for the central tracking device is a Time Projection Chamber (TPC). In this work a TPC with Gas Electron Multipliers (GEM) as gas amplification system was used. The GEMs replace the conventional wire amplification system of the TPC. In this PhD work a method to determine the drift velocity of a TPC was developed and tested using an ultraviolet laser. To ensure a high accuracy of the method all relevant gas parameters were measured with a slow control system. Furthermore the laser was used to investigate the separation capability of nearby tracks. Therefore an existing TPC prototype, which was developed to operate in a 5 T magnet facility

  3. GPU Computing Gems Emerald Edition

    CERN Document Server

    Hwu, Wen-mei W

    2011-01-01

    ".the perfect companion to Programming Massively Parallel Processors by Hwu & Kirk." -Nicolas Pinto, Research Scientist at Harvard & MIT, NVIDIA Fellow 2009-2010 Graphics processing units (GPUs) can do much more than render graphics. Scientists and researchers increasingly look to GPUs to improve the efficiency and performance of computationally-intensive experiments across a range of disciplines. GPU Computing Gems: Emerald Edition brings their techniques to you, showcasing GPU-based solutions including: Black hole simulations with CUDA GPU-accelerated computation and interactive display of

  4. The GEMS-2 SEIS Experiment

    Science.gov (United States)

    Tillier, S.; De Raucourt, S.; Mimoun, D.; Lognonne, P.; Giardini, D.; Christensen, U. R.; Pike, W. T.; Banerdt, B.; Laudet, P.; Kerjean, L.; Hurst, K. J.; Zweifel, P.; Mance, D.; Roll, R.; Bierwirth, M.; Gagnepain-Beyneix, J.; Nibut, T.; Robert, O.; Gabsi, T.; Pot, O.; Lecomte, B.; Schibler, P.; Mocquet, A.; Garcia, R.

    2011-12-01

    The SEIS experiment is the primary payload of the Geophysical Monitoring Station (GEMS) Mission Proposal, submitted to NASA in the frame of the 2010 Discovery program, and recently selected for the phase A study. The objective of the GEMS SEIS experiment is the determination of the deep internal structure of Mars. In particular, geophysical parameters of first importance, such as the state (liquid/solid) and size of the core, as well as structure of the mantle and shape of discontinuities will be determined by the experiment. It will measure seismic activity in a very broad band of signal, from the tidal frequencies (0.05 mHz) up to the short period frequencies (50 Hz), to address the widest range of scientific questions, from the state of the inner core to the meteoritic rate measurement. Infrasound, which might be associated to dust devils and atmospheric discharge, will be also monitored. The instrument integrates a Very Broad Band (VBB) 3 axis seismometer, completed by another trihedron of MEMS short period seismometers, environmental sensors for pressure, wind and temperature, and an infrasound sensor is additionally considered. The sensors will be deployed on the Martian ground by a robotic arm from the Phoenix lander platform and protected by a wind and thermal shield. The sensor assembly, which contains all seismic sensors, the leveling system, as well as house-keeping and temperature measurements, will be deployed on the soil in order to allow the best possible mechanical coupling with the ground motion. Thanks to the wind and thermal shield, together with the sensors' specific containers (vacuum sphere for VBBs), long term VBB bias will be protected from both temperature and pressure variations (as well as passively compensated), allowing the sensor to operate in the rough Martian thermal environment. A dedicated electronics will manage the overall experiment and ultra-low noise, space qualified 24 bits A/D converters will perform the acquisition. The

  5. ROLE OF GEMS IN INDIAN MEDICINE

    Science.gov (United States)

    Murthy, S.R.N.

    1991-01-01

    This paper is the first attempt in introducing the medicinal importance of gems as found in the Sanskrit text ‘Rasaratnasamuccaya’, which has been rendered an English translation here. The modern physicians and gemologists will find this study quite useful in continuing research and, thus, develop a new field of gem medicine. PMID:22556526

  6. Design approach for granular emulsion mixes (GEMS)

    CSIR Research Space (South Africa)

    Grobler, JE

    1994-10-01

    Full Text Available ) is presented. An “asphalt” approach is used in the design of stabilised GEMS with residual binder contents of more than 1,5%, using design methods such as the Marshall mix design method. A “gravel” approach is used in the design of modified GEMS with residual...

  7. The TOTEM T2 telescope based on triple-GEM chambers

    CERN Document Server

    Bagliesi, M G; Brucken, E; Cecchi, R; David, E; Garcia, F; Greco, V; Heino, J; Hilden, T; Kurvinen, K; Lauhakangas, R; Lami, S; Latino, G; Magazzu, G; Oliveri, E; Pedreschi, E; Ropelewski, L; Scribano, A; Spinella, F; Turini, N; van Stenis, M

    2010-01-01

    The TOTEM experiment at LHC has chosen the triple Gas Electron Multiplier (GEM) technology for its T2 telescope which will provide charged track reconstruction in the pseudorapidity range 5.3<|η|<6.5 and a fully inclusive trigger for inelastic events. GEMs are gas filled detectors which combine good spatial resolution with very high rate capability and a good resistance to radiation. Preliminary results of cosmic ray tests performed at CERN on final T2 modules before installation are here presented. Comparisons between real and simulated detector performance are also shown.

  8. The TOTEM T2 telescope based on triple-GEM chambers

    Energy Technology Data Exchange (ETDEWEB)

    Bagliesi, M.G., E-mail: mg.bagliesi@pi.infn.i [University of Siena and INFN Pisa (Italy); Berretti, M. [University of Siena and INFN Pisa (Italy); Brucken, E. [Helsinki (Finland); Cecchi, R. [University of Siena and INFN Pisa (Italy); David, E. [CERN, Geneva (Switzerland); Garcia, F. [Helsinki (Finland); Greco, V. [University of Siena and INFN Pisa (Italy); Heino, J.; Hilden, T.; Kurvinen, K.; Lauhakangas, R. [Helsinki (Finland); Lami, S.; Latino, G.; Magazzu, G.; Oliveri, E.; Pedreschi, E. [University of Siena and INFN Pisa (Italy); Ropelewski, L. [CERN, Geneva (Switzerland); Scribano, A.; Spinella, F.; Turini, N. [University of Siena and INFN Pisa (Italy)

    2010-05-21

    The TOTEM experiment at LHC has chosen the triple Gas Electron Multiplier (GEM) technology for its T2 telescope which will provide charged track reconstruction in the pseudorapidity range 5.3<|{eta}|<6.5 and a fully inclusive trigger for inelastic events. GEMs are gas filled detectors which combine good spatial resolution with very high rate capability and a good resistance to radiation. Preliminary results of cosmic ray tests performed at CERN on final T2 modules before installation are here presented. Comparisons between real and simulated detector performance are also shown.

  9. Experimental and simulation study of the behaviour and operation modes of MSGC+GEM detectors

    Energy Technology Data Exchange (ETDEWEB)

    Ageron, M.; Albert, A.; Barvich, T.; Beaumont, W.; Beckers, T.; Bernier, K.; Bluem, P.; Boulogne, I.; Bouvet, D.; Brom, J.M.; Charles, F.; Coffin, J.; Contardo, D.; Daubie, E.; Didierjean, F.; De Lentdecker, G. E-mail: delentdecker@hep.iihe.ac.be; De Troy, J.; Devroede, O.; Erdmann, M.; Ernenwein, J.P.; Fahrer, M.; Fluegge, G.; Fontaine, J.C.; Geist, W.; Goerlach, U.; Gottschalk, M.; Helleboid, J.M.; Huss, D.; Iacopi, F.; Juillot, P.; Kaercher, K.; Kuehn, F.; Lounis, A.; Maazouzi, C.; Macke, D.; Martin, C.; Mirabito, L.; Moreau, S.; Mueller, T.; Neuberger, D.; Nowack, A.; Perries, S.; Ripp-Baudot, I.; Roederer, F.; Schulte, R.; Shekhtman, L.; Simonis, H.J.; Struczinski, W.; Tatarinov, A.; Thuemmel, W.H.; Udo, F.; Vander Velde, C.; Van Doninck, W.; Van Dyck, C.; Vanlaer, P.; Van Lancker, L.; Weiler, T.; Zander, A.; Zghiche, A.; Zhukov, V

    2002-08-21

    A small series production of detector modules made of MicroStrip Gas Counters (MSGC) and a Gas Electron Multiplier (GEM) foil has been exposed to a high-intensity hadron beam. We report about the reproductibility and stability of the detector responses and about the occurrence and consequences of discharges in the detector. The interdependence of the four voltage differences used in the detector has been studied by simulation and with X-ray measurements. Rate dependence of the signal amplitude is observed. The behaviour of the MSGC+GEM is compared to that of a state-of-the-art MSGC. Influence of various parameters on the detector response is investigated.

  10. Microstructured boron foil scintillating G-GEM detector for neutron imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fujiwara, Takeshi, E-mail: fujiwara-t@aist.go.jp [Research Institute for Measurement and Analytical Instrumentation, Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki (Japan); Center for Advanced Photonics, Neutron Beam Technology Team, RIKEN, Saitama (Japan); Bautista, Unico [Department of Nuclear Engineering and Management, The University of Tokyo, Tokyo (Japan); Philippine Nuclear Research Institute-Department of Science and Technology (PNRI-DOST), Commonwealth Avenue, Diliman, Quezon City (Philippines); Mitsuya, Yuki [Nuclear Professional School, The University of Tokyo, Tokai-mura, Naka-gun, Ibaraki (Japan); Takahashi, Hiroyuki [Department of Nuclear Engineering and Management, The University of Tokyo, Tokyo (Japan); Yamada, Norifumi L. [Neutron Science Laboratory, Institute of Material Structure Science, High Energy Accelerator Research Organization (KEK) (Japan); Otake, Yoshie; Taketani, Atsushi [Center for Advanced Photonics, Neutron Beam Technology Team, RIKEN, Saitama (Japan); Uesaka, Mitsuru [Nuclear Professional School, The University of Tokyo, Tokai-mura, Naka-gun, Ibaraki (Japan); Toyokawa, Hiroyuki [Research Institute for Measurement and Analytical Instrumentation, Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki (Japan)

    2016-12-01

    In this study, a new simple neutron imaging gaseous detector was successfully developed by combining a micro-structured {sup 10}B foil, a glass gas electron multiplier (G-GEM), and a mirror–lens–charge-coupled device (CCD)–camera system. The neutron imaging system consists of a chamber filled with Ar/CF{sub 4} scintillating gas mixture. Inside this system, the G-GEM is mounted for gas multiplication. The neutron detection in this system is based on the reaction between {sup 10}B and neutrons. A micro-structured {sup 10}B is developed to overcome the issue of low detection efficiency. Secondary electrons excite Ar/CF{sub 4} gas molecules, and high-yield visible photons are emitted from those excited gas molecules during the gas electron multiplication process in the G-GEM holes. These photons are easily detected by a mirror–lens–CCD–camera system. A neutron radiograph is then simply formed. We obtain the neutron images of different materials with a compact accelerator-driven neutron source. We confirm that the new scintillating G-GEM-based neutron imager works properly with low gamma ray sensitivity and exhibits a good performance as a new simple digital neutron imaging device.

  11. The TOTEM GEM Telescope (T2) at the LHC

    International Nuclear Information System (INIS)

    Quinto, M.; Berretti, M.; David, E.; Garcia, F.; Greco, V.; Heino, J.; Hilden, T.; Kurvinen, K.; Lami, S.; Latino, G.; Lauhakangas, R.; Oliveri, E.; Ropelewski, L.; Scribano, A.; Turini, N.; Stenis, M. van

    2011-01-01

    The TOTEM T2 telescope will measure inelastically produced charged particles in the forward region of the LHC Interaction Point 5. Each arm of the telescope consists in a set of 20 triple-GEM (Gas Electron Multiplier) detectors with tracking and trigger capabilities. The GEM technology has been considered for the design of TOTEM very forward T2 telescopes thanks to its characteristics: large active areas, good position and timing resolution, excellent rate capability and radiation hardness. Each of the four T2 half arms has been fully assembled and equipped with electronics at CERN and systematically tested in the SPS beam line H8 in 2008/09. After some optimization, the operation of the GEM chambers was fully satisfactory and the T2 telescopes were installed and commissioned in their final positions at the LHC interaction point. During the first LHC run (December 2009) the T2 telescopes have collected data, at 900 GeV and 2.36 TeV. We will present here the performances of the detector and the preliminary results obtained using the data collected.

  12. The TOTEM GEM Telescope (T2) at the LHC

    Energy Technology Data Exchange (ETDEWEB)

    Quinto, M. [INFN Sezione di Bari, Via E.Orabona n 4, 70126 Bari (Italy); Berretti, M. [University of Siena, Physics Department, Via Roma 56, I-53100 Siena (Italy); INFN Sezione di Pisa, Largo B. Pontecorvo, 3. I-56127. Pisa (Italy); David, E. [CERN, PH Department, 1211 Geneva 23, Geneva (Switzerland); Garcia, F. [University of Helsinki, Institute of Physics and Department of Physical Sciences, Helsinki (Finland); Greco, V. [University of Siena, Physics Department, Via Roma 56, I-53100 Siena (Italy); INFN Sezione di Pisa, Largo B. Pontecorvo, 3. I-56127. Pisa (Italy); Heino, J.; Hilden, T.; Kurvinen, K. [University of Helsinki, Institute of Physics and Department of Physical Sciences, Helsinki (Finland); Lami, S. [INFN Sezione di Pisa, Largo B. Pontecorvo, 3. I-56127. Pisa (Italy); Latino, G. [University of Siena, Physics Department, Via Roma 56, I-53100 Siena (Italy); INFN Sezione di Pisa, Largo B. Pontecorvo, 3. I-56127. Pisa (Italy); Lauhakangas, R. [University of Helsinki, Institute of Physics and Department of Physical Sciences, Helsinki (Finland); Oliveri, E. [University of Siena, Physics Department, Via Roma 56, I-53100 Siena (Italy); INFN Sezione di Pisa, Largo B. Pontecorvo, 3. I-56127. Pisa (Italy); Ropelewski, L. [CERN, PH Department, 1211 Geneva 23, Geneva (Switzerland); Scribano, A.; Turini, N. [University of Siena, Physics Department, Via Roma 56, I-53100 Siena (Italy); INFN Sezione di Pisa, Largo B. Pontecorvo, 3. I-56127. Pisa (Italy); Stenis, M. van [CERN, PH Department, 1211 Geneva 23, Geneva (Switzerland)

    2011-06-15

    The TOTEM T2 telescope will measure inelastically produced charged particles in the forward region of the LHC Interaction Point 5. Each arm of the telescope consists in a set of 20 triple-GEM (Gas Electron Multiplier) detectors with tracking and trigger capabilities. The GEM technology has been considered for the design of TOTEM very forward T2 telescopes thanks to its characteristics: large active areas, good position and timing resolution, excellent rate capability and radiation hardness. Each of the four T2 half arms has been fully assembled and equipped with electronics at CERN and systematically tested in the SPS beam line H8 in 2008/09. After some optimization, the operation of the GEM chambers was fully satisfactory and the T2 telescopes were installed and commissioned in their final positions at the LHC interaction point. During the first LHC run (December 2009) the T2 telescopes have collected data, at 900 GeV and 2.36 TeV. We will present here the performances of the detector and the preliminary results obtained using the data collected.

  13. Study of relevant parameters of GEM-based detectors

    CERN Document Server

    Croci, Gabriele; Sauli, Fabio; Ragazzi, S

    2007-01-01

    The Gas Electron Multiplier consist of a thin Kapton insulating (50 $\\mu$m) foil copper-clad on both sides and perforated by a high density, regular matrix of holes (around 100 per square millimeter). Typically the distance between holes (pitch) is 140 $\\mu$m and diameters of about 70 $\\mu$m. The mesh is realised by conventional photolitographic methods as used for the fabrication of multi-layer board. Upon application of a potential difference between the GEM electrodes, a high dipole field develops in the holes focusing the field lines between the drift electrode and the readout element. Electron drift along the channel and the charge is amplified by a factor that depends on the field density and the length of the channel. Owing to their excellent position resolution and rate capability GEM-based detector are very suitable to be used in different applications: from the high energy physics to the medical field. The GEM temporal and rate gain stability was studied and it was discovered that the gain variation...

  14. Measurements of ion mobility and GEM discharge studies for the upgrade of the ALICE time projection chamber

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00507268

    2018-02-20

    ALICE is one of the four experiments at the Large Hadron Collider (LHC). The quark-gluon plasma, which is predominantly produced in lead-lead collisions at LHC, is of particular interest for ALICE. After the long shut-down 2 (2019-2021) the LHC will provide lead-lead collisions at an increased interaction rate of 50 kHz. In order to examine every event at this interaction rate the ALICE Time Projection Chamber (TPC) needs to be upgraded. The TPC’s ReadOut Chambers (ROCs) are currently multi-wire proportional chambers. To prevent space charge build-up of slow ions, drifting from the ROCs into the TPC, a gating grid is used. The corresponding closure time imposes a dead time on the TPC read out, which prohibits data taking at a readout rate higher than 3 kHz. New ROCs have therefore been designed, relying on stacks of Gas Electron Multiplier (GEM) foils for the gas amplification, allowing for continuous readout. With the new ROCs, a certain fraction of ions will be drifting at all time into the TPC. Knowing t...

  15. Fast drift CRID with GEM

    CERN Document Server

    Vavra, J; McCulloch, M; Stiles, P; Sauli, Fabio

    1999-01-01

    The only available technique at the present time, to perform particle identification up to 40-50 GeV/c in a 4 pi solenoidal geometry using the Cherenkov ring imaging method is the use of gaseous detectors filled with either TMAE or TEA photocathodes, and a combination of the gaseous, and solid or liquid radiators. If one would consider building such a device, one may want to investigate alternative methods of building a single-electron detector. This paper investigates the feasibility of using the GEM together with a simple MWPC detector employing 33 mu m diameter carbon wires to obtain a second coordinate. The results are compared to the CRID single-electron detector.

  16. Amplification of spontaneous emission of neon-like argon in a fast gas-filled capillary discharge

    Czech Academy of Sciences Publication Activity Database

    Koláček, Karel; Schmidt, Jiří; Boháček, Vladislav; Řípa, Milan; Frolov, Oleksandr; Vrba, Pavel; Štraus, Jaroslav; Prukner, Václav; Rupasov, A. A.; Shikanov, A. S.

    2008-01-01

    Roč. 34, č. 2 (2008), s. 162-168 ISSN 1063-780X R&D Projects: GA ČR GA202/06/1324; GA MŠk LA08024; GA AV ČR KJB100430702; GA AV ČR KAN300100702 Institutional research plan: CEZ:AV0Z20430508 Keywords : soft X-ray * laser * fast high-current * capillary discharge Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 0.785, year: 2008

  17. Studying discharges in the Gas Electron Multiplies in Alice Detector

    CERN Document Server

    EُlGedawy, Omar

    2016-01-01

    Characterizing discharges is very important in the operation of the GEM detector. Once the discharges happen, a current will go through the GEM, the voltages across the GEM foils sides drop, charge amplification cannot take place anymore, resulting in a loss of signal. So the goal is to understand how the discharges evolve and propagate, in order to find requirements on the voltage settings, which allow to decrease the discharge probability.

  18. A High Position Resolution X-ray Detector: an Edge on Illuminated Capillary Plate Combined with a Gas Amplification Structure

    CERN Document Server

    Iacobaeus, C.; Lund-Jensen, B.; Ostling, J.; Pavlopoulos, P.; Peskov, V.; Tokanai, F.

    2006-01-01

    We have developed and successfully tested a prototype of a new type of high position resolution hybrid X-ray detector. It contains a thin wall lead glass capillary plate converter of X-rays combined with a microgap parallel-plate avalanche chamber filled with gas at 1 atm. The operation of these converters was studied in a wide range of X-ray energies (from 6 to 60 keV) at incident angles varying from 0-90 degree. The detection efficiency, depending on the geometry, photon energy, incident angle and the mode of operation, was between 5-30 percent in a single step mode and up to 50 percent in a multi-layered combination. Depending on the capillary geometry, the position resolution achieved was between 0.050-0.250 mm in digital form and was practically independent of the photon energy or gas mixture. The usual lead glass capillary plates operated without noticeable charging up effects at counting rates of 50 Hz/mm2, and hydrogen treated capillaries up to 10E5 Hz/mm2. The developed detector may open new possibil...

  19. Design of data acquisition system for GEM detector

    International Nuclear Information System (INIS)

    Lu Jianliang; Chen Ziyu; Shen Ji; Jin Xi

    2011-01-01

    It describes the design and realization of the USB 2.0 high speed data acquisition devise which is used in the readout electronics of the GEM (gas electron multiplier) detector. By using of the USB Microcontroller EZ-USB FX2 CY7C68013A, high speed ADC and FPGA, high-speed data rate of data acquisition and transmission was realized. The data rate reaches to 20 MByte/s, meeting the requirements of data acquisition and transmission of the detector. (authors)

  20. GEM Building Taxonomy (Version 2.0)

    Science.gov (United States)

    Brzev, S.; Scawthorn, C.; Charleson, A.W.; Allen, L.; Greene, M.; Jaiswal, Kishor; Silva, V.

    2013-01-01

    This report documents the development and applications of the Building Taxonomy for the Global Earthquake Model (GEM). The purpose of the GEM Building Taxonomy is to describe and classify buildings in a uniform manner as a key step towards assessing their seismic risk, Criteria for development of the GEM Building Taxonomy were that the Taxonomy be relevant to seismic performance of different construction types; be comprehensive yet simple; be collapsible; adhere to principles that are familiar to the range of users; and ultimately be extensible to non-buildings and other hazards. The taxonomy was developed in conjunction with other GEM researchers and builds on the knowledge base from other taxonomies, including the EERI and IAEE World Housing Encyclopedia, PAGER-STR, and HAZUS. The taxonomy is organized as a series of expandable tables, which contain information pertaining to various building attributes. Each attribute describes a specific characteristic of an individual building or a class of buildings that could potentially affect their seismic performance. The following 13 attributes have been included in the GEM Building Taxonomy Version 2.0 (v2.0): 1.) direction, 2.)material of the lateral load-resisting system, 3.) lateral load-resisting system, 4.) height, 5.) date of construction of retrofit, 6.) occupancy, 7.) building position within a block, 8.) shape of the building plan, 9.) structural irregularity, 10.) exterior walls, 11.) roof, 12.) floor, 13.) foundation system. The report illustrates the pratical use of the GEM Building Taxonomy by discussing example case studies, in which the building-specific characteristics are mapped directly using GEM taxonomic attributes and the corresponding taxonomic string is constructed for that building, with "/" slash marks separating attributes. For example, for the building shown to the right, the GEM Taxonomy string is: DX1/MUR+CLBRS+MOCL2/LWAL3/

  1. Development and applications of gas electron multiplier detectors

    CERN Document Server

    Sauli, Fabio

    2003-01-01

    An overview of the recent developments in the field of gas electron multiplier (GEM) detectors was presented. Cascading of several GEM foils permits the sustaining of large gains and thereby allows the detection of minimum ionizing particles. The application of GEM included, fast and position sensitive detection in particle physics, medicine, neutron spectrometry, and astrophysics. (Edited abstract) 19 Refs.

  2. LHCb: A fast triple-GEM detector for high-rate charged-particle triggering

    CERN Multimedia

    2001-01-01

    - GEM: Principle of Operation - Time Performances - Detector Prototypes and Test Setup - Gas Mixtures - Fields Optimisation - Vgem Optimisation Ar/CO2 (70/30) - Vgem Optimisation Ar/CO2/CF4 (60/20/20) - Time Distributions - Future Tests and Developments

  3. Quality assurance of GEM foils in the framework of the TPC upgrade in the ALICE experiment

    CERN Document Server

    Ozcelik, Melih Arslan

    2016-01-01

    In the framework of the TPC upgrade of the ALICE Experiment, new readout chambers will be installed during the LHC long shutdown 2, which is scheduled to start in July 2018. The current MWPCs (Multi Wire Proportional Chambers) will be replaced by readout chambers consisting of GEM (Gas Electron Multipliers) foils in order to meet the increasing readout rate requirements. QA (Quality Assurance) tests on the GEMs are performed to classify the foils. In this report we present the work done during the CERN Summer Student Programme 2016.

  4. Construction of the TH-GEM detector components for metrology of low energy ionizing radiation

    International Nuclear Information System (INIS)

    Silva, N.F.; Castro, M.C.; Caldas, L.V.E.; Silva, T.F.; Luz, H. Natal da

    2017-01-01

    The Gas Electron Multiplier (GEM) detector was originally proposed as a position sensitive detector to determine trajectories of particles prevenient from high energy collisions. In order to study the potential of TH-GEM type detectors in dosimetric applications for low energy X-rays, specifically for the mammography standard qualities, it was proposed to construct a prototype with characteristics suitable for such use. In this work the general, structural and material parameters applicable to the necessary conditions were defined, establishing the process of construction of the components of a prototype. (author)

  5. Slow photon amplification of gas-phase ethanol photo-oxidation in titania inverse opal photonic crystals

    Energy Technology Data Exchange (ETDEWEB)

    Jovic, Vedran, E-mail: vjov001@aucklanduni.ac.nz [School of Chemical Sciences, Science Centre, Building 301, 23 Symonds Street, Auckland 92019 (New Zealand); Idriss, Hicham, E-mail: IdrissH@sabic.com [Corporate Research and Development (CRD), Saudi Basic Industries Corporation (SABIC) at KAUST (Saudi Arabia); Waterhouse, Geoffrey I.N., E-mail: g.waterhouse@auckland.ac.nz [School of Chemical Sciences, Science Centre, Building 301, 23 Symonds Street, Auckland 92019 (New Zealand); The MacDiarmid Institute for Advanced Materials and Nanotechnology (New Zealand); Dodd Walls Centre for Photonic and Quantum Technologies (New Zealand)

    2016-11-10

    Here we describe the successful fabrication of six titania inverse opal (TiO{sub 2} IO) photocatalysts with fcc[1 1 1] pseudo photonic band gaps (PBGs) tuned to span the UV–vis region. Photocatalysts were fabricated by a colloidal crystal templating and sol-gel approach – a robust and highly applicable bottom-up scheme which allowed for precise control over the geometric and optical properties of the TiO{sub 2} IO photocatalysts. Optical properties of the TiO{sub 2} IO thin films were investigated in detail by UV–vis transmittance and reflectance measurements. The PBG along the fcc[1 1 1] direction in the TiO{sub 2} IOs was dependent on the inter-planar spacing in the [1 1 1] direction, the incident angle of light and the refractive index of the medium filling the macropores in the IOs, in agreement with a modified Bragg’s law expression. Calculated photonic band structures for the photocatalysts revealed a PBG along the Γ → L direction at a/λ ∼ 0.74, in agreement with the experimental optical data. By coupling the low frequency edge of the PBG along the [1 1 1] direction with the electronic absorption edge of anatase TiO{sub 2}, a two-fold enhancement in the rate of gas phase ethanol photo-oxidation in air was achieved. This enhancement appears to be associated with a ‘slow photon’ effect that acts to both enhance TiO{sub 2} absorption and inhibit spontaneous emission (i.e. suppress electron-hole pair recombination).

  6. Quality control for the first large areas of triple-GEM chambers for the CMS endcaps

    Science.gov (United States)

    Abbaneo, D.; Abbas, M.; Abbrescia, M.; Abi Akl, M.; Aboamer, O.; Acosta, D.; Ahmad, A.; Ahmed, W.; Aleksandrov, A.; Altieri, P.; Asawatangtrakuldee, C.; Aspell, P.; Assran, Y.; Awan, I.; Bally, S.; Ban, Y.; Banerjee, S.; Barashko, V.; Barria, P.; Bencze, G.; Beni, N.; Benussi, L.; Bhopatkar, V.; Bianco, S.; Bos, J.; Bouhali, O.; Braghieri, A.; Braibant, S.; Buontempo, S.; Calabria, C.; Caponero, M.; Caputo, C.; Cassese, F.; Castaneda, A.; Cauwenbergh, S.; Cavallo, F. R.; Celik, A.; Choi, M.; Choi, S.; Christiansen, J.; Cimmino, A.; Colafranceschi, S.; Colaleo, A.; Conde Garcia, A.; Czellar, S.; Dabrowski, M. M.; De Lentdecker, G.; De Oliveira, R.; de Robertis, G.; Dildick, S.; Dorney, B.; Endroczi, G.; Errico, F.; Fenyvesi, A.; Ferry, S.; Furic, I.; Giacomelli, P.; Gilmore, J.; Golovtsov, V.; Guiducci, L.; Guilloux, F.; Gutierrez, A.; Hadjiiska, R. M.; Hauser, J.; Hoepfner, K.; Hohlmann, M.; Hoorani, H.; Iaydjiev, P.; Jeng, Y. G.; Kamon, T.; Karchin, P.; Korytov, A.; Krutelyov, S.; Kumar, A.; Kim, H.; Lee, J.; Lenzi, T.; Litov, L.; Loddo, F.; Madorsky, A.; Maerschalk, T.; Maggi, M.; Magnani, A.; Mal, P. K.; Mandal, K.; Marchioro, A.; Marinov, A.; Majumdar, N.; Merlin, J. A.; Mitselmakher, G.; Mohanty, A. K.; Mohapatra, A.; Molnar, J.; Muhammad, S.; Mukhopadhyay, S.; Naimuddin, M.; Nuzzo, S.; Oliveri, E.; Pant, L. M.; Paolucci, P.; Park, I.; Passeggio, G.; Pavlov, B.; Philipps, B.; Piccolo, D.; Postema, H.; Puig Baranac, A.; Radi, A.; Radogna, R.; Raffone, G.; Ranieri, A.; Rashevski, G.; Riccardi, C.; Rodozov, M.; Rodrigues, A.; Ropelewski, L.; RoyChowdhury, S.; Ryu, G.; Ryu, M. S.; Safonov, A.; Salva, S.; Saviano, G.; Sharma, A.; Sharma, A.; Sharma, R.; Shah, A. H.; Shopova, M.; Sturdy, J.; Sultanov, G.; Swain, S. K.; Szillasi, Z.; Talvitie, J.; Tatarinov, A.; Tuuva, T.; Tytgat, M.; Vai, I.; Van Stenis, M.; Venditti, R.; Verhagen, E.; Verwilligen, P.; Vitulo, P.; Volkov, S.; Vorobyev, A.; Wang, D.; Wang, M.; Yang, U.; Yang, Y.; Yonamine, R.; Zaganidis, N.; Zenoni, F.; Zhang, A.

    2018-02-01

    The CMS Collaboration plans to equip the very forward muon system with triple-GEM detectors that can withstand the environment of the High-Luminosity LHC. This project is at the final stages of R&D and moving to production. An unprecedented large area of several 100 m2 are to be instrumented with GEM detectors which will be produced in six different sites around the world. A common construction and quality control procedure is required to ensure the performance of each detector. The quality control steps will include optical inspection, cleaning and baking of all materials and parts used to build the detector, leakage current tests of the GEM foils, high voltage tests, gas leak tests of the chambers and monitoring pressure drop vs. time, gain calibration to know the optimal operation region of the detector, gain uniformity tests, and studying the efficiency, noise and tracking performance of the detectors in a cosmic stand using scintillators.

  7. Quality control for the first large areas of triple-GEM chambers for the CMS endcaps

    CERN Document Server

    AUTHOR|(CDS)2068936; Abbas, M.; Abbrescia, M.; Abi Akl, M.; Aboamer, O.; Acosta, D.; Ahmad, A.; Ahmed, W.; Aleksandrov, A.; Altieri, P.; Asawatangtrakuldee, C.; Aspell, P.; Assran, Y.; Awan, I.; Bally, S.; Ban, Y.; Banerjee, S.; Barashko, V.; Barria, P.; Bencze, G.; Beni, N.; Benussi, L.; Bhopatkar, V.; Bianco, S.; Bos, J.; Bouhali, O.; Braghieri, A.; Braibant, S.; Buontempo, S.; Calabria, C.; Caponero, M.; Caputo, C.; Cassese, F.; Castaneda, A.; Cauwenbergh, S.; Cavallo, F.R.; Celik, A.; Choi, M.; Choi, S.; Christiansen, J.; Cimmino, A.; Colafranceschi, S.; Colaleo, A.; Conde Garcia, A.; Czellar, S.; Dabrowski, M.M.; De Lentdecker, G.; De Oliveira, R.; de Robertis, G.; Dildick, S.; Dorney, B.; Endroczi, G.; Errico, F.; Fenyvesi, A.; Ferry, S.; Furic, I.; Giacomelli, P.; Gilmore, J.; Golovtsov, V.; Guiducci, L.; Guilloux, F.; Gutierrez, A.; Hadjiiska, R.M.; Hauser, J.; Hoepfner, K.; Hohlmann, M.; Hoorani, H.; Iaydjiev, P.; Jeng, Y.G.; Kamon, T.; Karchin, P.; Korytov, A.; Krutelyov, S.; Kumar, A.; Kim, H.; Lee, J.; Lenzi, T.; Litov, L.; Loddo, F.; Madorsky, A.; Maerschalk, T.; Maggi, M.; Magnani, A.; Mal, P.K.; Mandal, K.; Marchioro, A.; Marinov, A.; Majumdar, N.; Merlin, J.A.; Mitselmakher, G.; Mohanty, A.K.; Mohapatra, A.; Molnar, J.; Muhammad, S.; Mukhopadhyay, S.; Naimuddin, M.; Nuzzo, S.; Oliveri, E.; Pant, L.M.; Paolucci, P.; Park, I.; Passeggio, G.; Pavlov, B.; Philipps, B.; Piccolo, D.; Postema, H.; Puig Baranac, A.; Radi, A.; Radogna, R.; Raffone, G.; Ranieri, A.; Rashevski, G.; Riccardi, C.; Rodozov, M.; Rodrigues, A.; Ropelewski, L.; RoyChowdhury, S.; Ryu, G.; Ryu, M.S.; Safonov, A.; Salva, S.; Saviano, G.; Sharma, A.; Sharma, A.; Sharma, R.; Shah, A.H.; Shopova, M.; Sturdy, J.; Sultanov, G.; Swain, S.K.; Szillasi, Z.; Talvitie, J.; Tatarinov, A.; Tuuva, T.; Vai, I.; Van Stenis, M.; Venditti, R.; Verhagen, E.; Verwilligen, P.; Vitulo, P.; Volkov, S.; Vorobyev, A.; Wang, D.; Wang, M.; Yang, U.; Yang, Y.; Yonamine, R.; Zaganidis, N.; Zenoni, F.; Zhang, A.

    2015-01-01

    The CMS Collaboration plans to equip the very forward muon system with triple-GEM detectors that can withstand the environment of the High-Luminosity LHC. This project is at the final stages of R&D and moving to production. An unprecedented large area of several 100 m2 are to be instrumented with GEM detectors which will be produced in six different sites around the world. A common construction and quality control procedure is required to ensure the performance of each detector. The quality control steps will include optical inspection, cleaning and baking of all materials and parts used to build the detector, leakage current tests of the GEM foils, high voltage tests, gas leak tests of the chambers and monitoring pressure drop vs. time, gain calibration to know the optimal operation region of the detector, gain uniformity tests, and studying the efficiency, noise and tracking performance of the detectors in a cosmic stand using scintillators.

  8. GEM Detectors in the Experiments at e+e- Colliders in BINP

    CERN Document Server

    Maltsev, T V

    2017-01-01

    Micro-pattern gaseous detectors possess a high spatial resolution in tens micron scale together with high rate capability up to 107 cm-2s-1. In addition, they have all advantages of gaseous detectors, such as relatively low costs per unit area, the possibility to equip a large area as well as a high uniformity. Cascaded Gas Electron Multiplier (GEM) based detectors are used in the collider experiments at Budker Institute of Nuclear Physics (BINP), and they are being developed for a number of new projects. In this article the review of GEM based detectors for the tagging system of the KEDR experiment at the VEPP-4M collider and for the DEUTERON facility at the VEPP-3 storage ring is presented. The GEM detector application of the CMD-3 detector upgrade at the VEPP-2000 collider and the Super τ Factory detector are discussed.

  9. A new design using GEM-based technology for the CMS experiment

    CERN Document Server

    Ressegotti, Martina

    2017-01-01

    The muon system of the Compact Muon Solenoid (CMS) experiment at the LHC is currently not instrumented for pseudorapidity higher than abs(${\\eta}$)${ > 2.4}$. The main challenges to the installation of a detector in that position are the high particle flux to be sustained, a high level of radiation, and the ability to accomodate a multilevel detector into the small available space (less than 30 cm). A new back-to-back configuration of a Gas Electron Multiplier (GEM) detector is presented with the aim of developing a compact, multi-layer GEM detector. It is composed of two independent stacked triple-GEM detectors, positioned with the anodes toward the outside and sharing the same cathode plane, which is located at the center of the chamber, to reduce the total detector's thickness. A first prototype has been produced and tested with an X-Ray source and muon beam. First results on its performance are presented.

  10. SUPERCOLLIDER: A GEM of a detector

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    Now being prepared as a major experimental facility for the 87- kilometre Superconducting Supercollider (SSC) being built in Ellis County, Texas, is the GEM detector project. GEM thus becomes the companion to the Solenoidal Detector Collaboration (SDC), the first major SSC detector to emerge (March 1992, page 13). This is in keeping with the SSC Laboratory's aim of two major detectors with overlapping and complementary strengths. GEM is designed to observe all SSC signatures, with emphasis on precise measurement of electrons, photons and muons. Hence the name GEM - ''Gammas, Electrons and Muons.'' Design goals are clean signatures for leptons, jets, and missing transverse energy, maximum sensitivity to narrow resonances, and low backgrounds. Also important is maintaining significant capability at high luminosity (10 34 cm -2 s -1 ). GEM has some distinctive features. A key concept is the exterior magnet, surrounding all detector elements. Inside the magnet are a muon tracking system, a precision calorimeter, and a compact central tracker. This allows the muon momentum to be measured the air of the radiation shielded area outside the thick calorimeter, giving both high precision and robustness at high luminosity. A large magnet gives a large lever arm (at least 4 m) for precise muon momentum measurement. Placing the magnet outside also minimizes the material between tracker and calorimeters, so that the calorimeters are limited only by their inherent resolutions

  11. Development of Large Area Gas Electron Multiplier Detector and Its Application to a Digital Hadron Calorimeter for Future Collider Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Jaehoon; White, Andrew

    2014-09-25

    The UTA High Energy Physics Group conducted generic detector development based on large area, very thin and high sensitivity gas detector using gas electron multiplier (GEM) technology. This is in preparation for a use as a sensitive medium for sampling calorimeters in future collider experiments at the Energy Frontier as well as part of the tracking detector in Intensity Frontier experiments. We also have been monitoring the long term behavior of one of the prototype detectors (30cmx30cm) read out by the SLAC-developed 13-bit KPiX analog chip over three years and have made presentations of results at various APS meetings. While the important next step was the development of large area (1m x 1m) GEM planes, we also have looked into opportunities of applying this technology to precision tracking detectors to significantly improve the performance of the Range Stack detector for CP violation experiments and to provide an amplification layer for the liquid Argon Time Projection Chamber in the LBNE experiment. We have jointly developed 33cmx100cm large GEM foils with the CERN gas detector development group to construct 33cm x100cm unit chambers. Three of these unit chambers will be put together to form a 1m x 1m detector plane. Following characterization of one 33cmx100cm unit chamber prototype, a total of five 1m x 1m planes will be constructed and inserted into an existing 1m3 RPC DHCAL stack to test the performance of the new GEM DHCAL in particle beams. The large area GEM detector we planned to develop in this proposal not only gives an important option to DHCAL for future collider experiments but also the potential to expand its use to Intensity Frontier and Cosmic Frontier experiments as high efficiency, high amplification anode planes for liquid Argon time projection chambers. Finally, thanks to its sensitivity to X-rays and other neutral radiations and its light-weight characteristics, the large area GEM has a great potential for the use in medical imaging and

  12. FPGA-based GEM detector signal acquisition for SXR spectroscopy system

    Science.gov (United States)

    Wojenski, A.; Pozniak, K. T.; Kasprowicz, G.; Kolasinski, P.; Krawczyk, R.; Zabolotny, W.; Chernyshova, M.; Czarski, T.; Malinowski, K.

    2016-11-01

    The presented work is related to the Gas Electron Multiplier (GEM) detector soft X-ray spectroscopy system for tokamak applications. The used GEM detector has one-dimensional, 128 channel readout structure. The channels are connected to the radiation-hard electronics with configurable analog stage and fast ADCs, supporting speeds of 125 MSPS for each channel. The digitalized data is sent directly to the FPGAs using fast serial links. The preprocessing algorithms are implemented in the FPGAs, with the data buffering made in the on-board 2Gb DDR3 memory chips. After the algorithmic stage, the data is sent to the Intel Xeon-based PC for further postprocessing using PCI-Express link Gen 2. For connection of multiple FPGAs, PCI-Express switch 8-to-1 was designed. The whole system can support up to 2048 analog channels. The scope of the work is an FPGA-based implementation of the recorder of the raw signal from GEM detector. Since the system will work in a very challenging environment (neutron radiation, intense electro-magnetic fields), the registered signals from the GEM detector can be corrupted. In the case of the very intense hot plasma radiation (e.g. laser generated plasma), the registered signals can overlap. Therefore, it is valuable to register the raw signals from the GEM detector with high number of events during soft X-ray radiation. The signal analysis will have the direct impact on the implementation of photon energy computation algorithms. As the result, the system will produce energy spectra and topological distribution of soft X-ray radiation. The advanced software was developed in order to perform complex system startup and monitoring of hardware units. Using the array of two one-dimensional GEM detectors it will be possible to perform tomographic reconstruction of plasma impurities radiation in the SXR region.

  13. FPGA-based GEM detector signal acquisition for SXR spectroscopy system

    International Nuclear Information System (INIS)

    Wojenski, A.; Pozniak, K. T.; Kasprowicz, G.; Kolasinski, P.; Krawczyk, R.; Zabolotny, W.; Chernyshova, M.; Czarski, T.; Malinowski, K.

    2016-01-01

    The presented work is related to the Gas Electron Multiplier (GEM) detector soft X-ray spectroscopy system for tokamak applications. The used GEM detector has one-dimensional, 128 channel readout structure. The channels are connected to the radiation-hard electronics with configurable analog stage and fast ADCs, supporting speeds of 125 MSPS for each channel. The digitalized data is sent directly to the FPGAs using fast serial links. The preprocessing algorithms are implemented in the FPGAs, with the data buffering made in the on-board 2Gb DDR3 memory chips. After the algorithmic stage, the data is sent to the Intel Xeon-based PC for further postprocessing using PCI-Express link Gen 2. For connection of multiple FPGAs, PCI-Express switch 8-to-1 was designed. The whole system can support up to 2048 analog channels. The scope of the work is an FPGA-based implementation of the recorder of the raw signal from GEM detector. Since the system will work in a very challenging environment (neutron radiation, intense electro-magnetic fields), the registered signals from the GEM detector can be corrupted. In the case of the very intense hot plasma radiation (e.g. laser generated plasma), the registered signals can overlap. Therefore, it is valuable to register the raw signals from the GEM detector with high number of events during soft X-ray radiation. The signal analysis will have the direct impact on the implementation of photon energy computation algorithms. As the result, the system will produce energy spectra and topological distribution of soft X-ray radiation. The advanced software was developed in order to perform complex system startup and monitoring of hardware units. Using the array of two one-dimensional GEM detectors it will be possible to perform tomographic reconstruction of plasma impurities radiation in the SXR region.

  14. Amplification factor variable amplifier

    NARCIS (Netherlands)

    Akitsugu, Oshita; Nauta, Bram

    2007-01-01

    PROBLEM TO BE SOLVED: To provide an amplification factor variable amplifier capable of achieving temperature compensation of an amplification factor over a wide variable amplification factor range. ; SOLUTION: A Gilbert type amplification factor variable amplifier 11 amplifies an input signal and

  15. Amplification factor variable amplifier

    NARCIS (Netherlands)

    Akitsugu, Oshita; Nauta, Bram

    2010-01-01

    PROBLEM TO BE SOLVED: To provide an amplification factor variable amplifier capable of achieving temperature compensation of an amplification factor over a wide variable amplification factor range. ;SOLUTION: A Gilbert type amplification factor variable amplifier 11 amplifies an input signal and can

  16. Development of GEMs at Hampton University

    Science.gov (United States)

    Liyanage, Anusha; Kohl, Michael; MUSE Collaboration

    2015-10-01

    Two GEM telescopes each consisting of three 10×10 cm2 triple-GEM chambers 30-40 cm apart were built, tested and operated by the Hampton group. They are read out with APV25 frontend chips and FPGA based digitizing electronics developed by INFN Rome. The telescopes served as luminosity monitors for the OLYMPUS experiment at DESY in Hamburg, Germany, with positron and electron beams at 2 GeV. The telescopes have been recycled to serve as the beam particle tracker of the MUSE experiment at the Paul Scherrer Institute in Switzerland. In the identical configuration as in OLYMPUS, the telescope was limiting the accepted trigger rate in the test measurements. Therefore, an effort is ongoing to improve the GEM readout speed to meet the trigger rate at the design intensity of the MUSE experiment. Further, the Hampton group is responsible for the DarkLight phase-I lepton tracker which is in preparation at the low energy-recovering facility (LERF) at the Thomas Jefferson National Accelerator Facility in Newport News, USA, sponsored by the National Science Foundation through a Major Research Instrumentation (MRI) grant. The group's activities on GEM detector development will be summarized, and the achieved performance and the current effort to further improvements will be discussed.

  17. Fabrication and measurement of gas electron multiplier

    International Nuclear Information System (INIS)

    Zhang Minglong; Xia Yiben; Wang Linjun; Gu Beibei; Wang Lin; Yang Ying

    2005-01-01

    Gas electron multiplier (GEM) with special performance has been widely used in the field of radiation detectors. In this work, GEM film was fabricated using a 50 μm -thick kapton film by the therma evaporation and laser masking drilling technique. GEM film has many uniformly arrayed holes with a diameter of 100 μm and a gap of 223 μm. It was then set up to a gas-flowing detector with an effective area of 3 x 3 cm 2 , 5.9 keV X-ray generated from a 55 Fe source was used to measure the pulse height distribution of GEM operating at various high voltage and gas proportion. The effect of high potential and gas proportion on the count rate and the energy resolution was discussed in detail. The results indicate that GEM has a very high ratio of signal to noise and better energy resolution of 18.2%. (authors)

  18. The GEM-Mars general circulation model for Mars: Description and evaluation

    Science.gov (United States)

    Neary, L.; Daerden, F.

    2018-01-01

    GEM-Mars is a gridpoint-based three-dimensional general circulation model (GCM) of the Mars atmosphere extending from the surface to approximately 150 km based on the GEM (Global Environmental Multiscale) model, part of the operational weather forecasting and data assimilation system for Canada. After the initial modification for Mars, the model has undergone considerable changes. GEM-Mars is now based on GEM 4.2.0 and many physical parameterizations have been added for Mars-specific atmospheric processes and surface-atmosphere exchange. The model simulates interactive carbon dioxide-, dust-, water- and atmospheric chemistry cycles. Dust and water ice clouds are radiatively active. Size distributed dust is lifted by saltation and dust devils. The model includes 16 chemical species (CO2, Argon, N2, O2, CO, H2O, CH4, O3, O(1D), O, H, H2, OH, HO2, H2O2 and O2(a1Δg)) and has fully interactive photochemistry (15 reactions) and gas-phase chemistry (31 reactions). GEM-Mars provides a good simulation of the water and ozone cycles. A variety of other passive tracers can be included for dedicated studies, such as the emission of methane. The model has both a hydrostatic and non-hydrostatic formulation, and together with a flexible grid definition provides a single platform for simulations on a variety of horizontal scales. The model code is fully parallelized using OMP and MPI. Model results are evaluated by comparison to a selection of observations from instruments on the surface and in orbit, relating to atmosphere and surface temperature and pressure, dust and ice content, polar ice mass, polar argon, and global water and ozone vertical columns. GEM-Mars will play an integral part in the analysis and interpretation of data that is received by the NOMAD spectrometer on the ESA-Roskosmos ExoMars Trace Gas Orbiter. The present paper provides an overview of the current status and capabilities of the GEM-Mars model and lays the foundations for more in-depth studies in support

  19. arXiv GEM Foil Quality Assurance For The ALICE TPC Upgrade

    CERN Document Server

    INSPIRE-00019412; Hildén, Timo

    2018-01-01

    The ALICE (A Large Ion Collider Experiment) experiment at the Large Hadron Collider (LHC) at CERN is dedicated to heavy ion physics to explore the structure of strongly interacting matter. The Time Projection Chamber (TPC) of ALICE is a tracking detector located in the central region of the experiment. It offers excellent tracking capabilities as well as particle identification. After the second long shutdown (LS2) the LHC will run at substantially higher luminosities. To be able to increase the data acquisition rate by a factor of 100, the ALICE TPC experiment has to replace the Multi-Wire Proportional Chamber (MWPC) –based readout chambers. The MWPC are operated with gating grid that limits the rate to O(kHz). The new ReadOut Chamber (ROC) design is based on Gas Electron Multiplier (GEM) technology operating in continuous mode. The current GEM productions scheme foresees the production of more than 800 GEM foils of different types. To fulfill the requirements on the performance of the GEM TPC readout, nec...

  20. Elsevier Overview of large area triple-GEM detectors for the CMS forward muon upgrade

    CERN Document Server

    Abbaneo, D; Abbrescia, M; Abi Akl, M; Aboamer, O; Acosta, D; Ahmad, A; Ahmed, W; Aleksandrov, A; Altieri, P; Asawatangtrakuldee, C; Aspell, P; Assran, Y; Awan, I; Bally, S; Ban, Y; Banerjee, S; Barashko, V; Barria, P; Bencze, G; Beni, N; Benussi, L; Bhopatkar, V; Bianco, S; Bos, J; Bouhali, O; Braghieri, A; Braibant, S; Buontempo, S; Calabria, C; Caponero, M; Caputo, C; Cassese, F; Castaneda, A; Cauwenbergh, S; Cavallo, F R; Celik, A; Choi, M; Choi, S; Christiansen, J; Cimmino, A; Colafranceschi, S; Colaleo, A; Conde Garcia, A; Czellar, S; Dabrowski, M M; De Lentdecker, G; De Oliveira, R; de Robertis, G; Dildick, S; Dorney, B; Endroczi, G; Errico, F; Fenyvesi, A; Ferry, S; Furic, I; Giacomelli, P; Gilmore, J; Golovtsov, V; Guiducci, L; Guilloux, F; Gutierrez, A; Hadjiiska, R M; Hauser, J; Hoepfner, K; Hohlmann, M; Hoorani, H; Iaydjiev, P; Jeng, Y G; Kamon, T; Karchin, P; Korytov, A; Krutelyov, S; Kumar, A; Kim, H; Lee, J; Lenzi, T; Litov, L; Loddo, F; Madorsky, A; Maerschalk, T; Maggi, M; Magnani, A; Mal, P K; Mandal, K; Marchioro, A; Marinov, A; Majumdar, N; Merlin, J A; Mitselmakher, G; Mohanty, A K; Mohapatra, A; Molnar, J; Muhammad, S; Mukhopadhyay, S; Naimuddin, M; Nuzzo, S; Oliveri, E; Pant, L M; Paolucci, P; Park, I; Passeggio, G; Pavlov, B; Philipps, B; Piccolo, D; Postema, H; Puig Baranac, A; Radi, A; Radogna, R; Raffone, G; Ranieri, A; Rashevski, G; Riccardi, C; Rodozov, M; Rodrigues, A; Ropelewski, L; RoyChowdhury, S; Ryu, G; Ryu, M S; Safonov, A; Salva, S; Saviano, G; Sharma, A; Sharma, A; Sharma, R; Shah, A H; Shopova, M; Sturdy, J; Sultanov, G; Swain, S K; Szillasi, Z; Talvitie, J; Tatarinov, A; Tuuva, T; Tytgat, M; Vai, I; Van Stenis, M; Venditti, R; Verhagen, E; Verwilligen, P; Vitulo, P; Volkov, S; Vorobyev, A; Wang, D; Wang, M; Yang, U; Yang, Y; Yonamine, R; Zaganidis, N; Zenoni, F; Zhang, A

    2017-01-01

    We report on the status of the project to install large-area triple-foil gas electron multiplier (GEM) detectors in the end-cap muon system of the Compact Muon Solenoid (CMS) experiment at the LHC operating at the high luminosity planned after the current period of data-taking (run 2). In the pseudo-rapidity region $1.6 < \\lvert\\eta\\rvert < 2.4$, the GEM detectors will suppress the rate of background triggers while maintaining high trigger efficiency for low transverse momentum muons, and enhancing the robustness of muon detection in the high-flux environment of the end-cap region. GEM detectors will also be used to extend the range of muon identification up to about $\\lvert\\eta\\rvert = 3.0$. We describe the design of the GEM chambers, readout electronics, and data acquisition system for the three stations in each endcap, located at increasing distances from the interaction point. For the intermediate station, the design is fixed and we describe plans to install several of the intermediate station dete...

  1. CMS Muon System Phase 2 Upgrade with triple-GEM detectors

    CERN Document Server

    Salva Diblen, Sinem

    2015-01-01

    The Compact Muon Solenoid (CMS) detector installed at the CERN Large Hadron Collider (LHC) has an extensive muon system which provides information simultaneously for identification, track reconstruction and triggering of muons. As a consequence of the extreme particle rate and high integrated charge, the essentiality to upgrade the LHC has given rise to the High Luminosity phase of the LHC (HL-LHC) project so that the CMS muon system will be upgraded with superior technological challenges. The CMS GEM collaboration offers a solution to equip the high-eta region of the muon system for Phase 2 (after the year 2017) with large-area triple-layer Gas Electron Multiplier (GEM) detectors, since GEMs have the ability to provide robust and redundant tracking and triggering functions with an excellent spatial resolution of order 100 micron and a high particle rate capability, with a close to 100pct detection efficiency. In this contribution, the present status of the triple-GEM project will be reviewed, and the signifi...

  2. GEM detector performance and efficiency in Proton Charge Radius (PRad) Experiment

    Science.gov (United States)

    Bai, Xinzhan; PRad Collaboration

    2017-09-01

    The PRad experiment (E12-11-106) was performed in 2016 at Jefferson Lab in Hall B. It aims to investigate the proton charge radius puzzle through electron proton elastic scattering process. The experiment used a non-magnetic spectrometer method, and reached a very small ep scattering angle and thus an unprecedented small four-momentum transfer squared region, Q2 from 2 ×10-4 to 0.06(GeV / c) 2 . PRad experiment was designed to measure the proton charge radius within a sub-percent precision. Gas Electron Multiplier (GEM) detectors have contributed to reach the experimental goal. A pair of large area GEM detectors, and a large acceptance, high resolution calorimeter(HyCal) were utilized in the experiment to detect the scattered electrons. The precision requirements of the experiment demands a highly accurate understanding of efficiency and stability of GEM detectors. In this talk, we will present the preliminary results on the performance and efficiency of GEM detectors. This work is supported in part by NSF MRI award PHY-1229153, the U.S. Department of Energy under Contract No. DE-FG02-07ER41528, No. DE-FG02-03ER41240 and Thomas Jefferson National Laboratory.

  3. Implementation of the P barANDA Planar-GEM tracking detector in Monte Carlo simulations

    Science.gov (United States)

    Divani Veis, Nazila; Ehret, Andre; Firoozabadi, Mohammad M.; Karabowicz, Radoslaw; Maas, Frank; Saito, Nami; Saito, Takehiko R.; Voss, Bernd; PANDA Gem-Tracker Subgroup

    2018-02-01

    The P barANDA experiment at FAIR will be performed to investigate different aspects of hadron physics using anti-proton beams interacting with a fixed nuclear target. The experimental setup consists of a complex series of detector components covering a large solid angle. A detector with a gaseous active media equipped with gas electron multiplier (GEM) technique will be employed to measure tracks of charged particles at forward direction in order to achieve a high momentum resolution. In this work, a full setup of the GEM tracking detector has been implemented in the P barANDA Monte Carlo simulation package (PandaRoot) based on the current technical and conceptual design, and the expected performance of the P barANDA GEM-tracking detector has been investigated. Furthermore, material-budget studies in terms of the radiation length of the P barANDA GEM-tracking detector have been made in order to investigate the effect of the detector materials and its associated structures to particle measurements.

  4. Status of the Triple-GEM Project for the Upgrade of the CMS Muon System

    CERN Document Server

    Tytgat, Michael

    2013-01-01

    The GEMs for CMS collaboration is performing a feasibility study to install triple-GEM detectors in the forward region of the muon system ($1.6<\\eta<2.4$) of the CMS detector at the LHC. Such micro-pattern gas detectors are able to cope with the extreme particle rates that are expected in that region during the High Luminosity phase of the LHC. With their spatial resolution of order 100 micron GEMs would not only provide additional benefits in the CMS muon High Level Trigger, but also in the muon identification and track reconstruction, effectively combining tracking and triggering capabilities in one single device. The present status of the full project will be reviewed, highlighting all importants steps and achievements since the start of the R and D in 2009. Several small and full-size prototypes were constructed with different geometries and techniques. The baseline design of the triple-GEM detectorfor CMS will be described, along with the results from extensive test measurements of all prototypes ...

  5. BoNus: Development and use of a radial TPC using cylindrical GEMs

    International Nuclear Information System (INIS)

    A specialized system of target and detector was developed at Jefferson Lab to provide new access to information about neutron structure from electron-neutron interactions. It allows identification and measurement of spectator protons produced in e - d→e - p s X scattering events. The detector is a radial time-projection chamber optimized for the acceptance of low-momentum protons. Gas gain is provided by three cascaded curved Gas Electron Multipliers (GEMs), the first application of GEMs in any configuration other than flat. This article provides details about the development and construction of the detector, its performance, and the analysis of the data from the successful running of its first physics experiment

  6. Studies on GEM modules for a large prototype TPC for the ILC

    International Nuclear Information System (INIS)

    Tsionou, Dimitra

    2016-12-01

    The International Linear Collider (ILC) is a future electron-positron collider with centre of mass energy of 500-1000 GeV. The International Large Detector (ILD) is one of two detector concepts at the ILC. Its high precision tracking system consists of Silicon sub-detectors and a Time Projection Chamber (TPC) equipped with micro-pattern gas detectors (MPGDs). Within the framework of the LCTPC collaboration, a Large Prototype (LP) TPC has been built as a demonstrator. This prototype has been equipped with Gas Electron Multiplier (GEM) modules and studied with electron beams of energies 1-6 GeV at the DESY test beam facility. The performance of the prototype detector and the extrapolation to the ILD TPC is presented here. In addition, ongoing optimisation studies and R and D; activities in order to prepare the next GEM module iteration are discussed.

  7. Studies on GEM modules for a Large Prototype TPC for the ILC

    International Nuclear Information System (INIS)

    Tsionou, Dimitra

    2017-01-01

    The International Linear Collider (ILC) is a future electron–positron collider with centre of mass energy of 500–1000 GeV. The International Large Detector (ILD) is one of two detector concepts at the ILC. Its high precision tracking system consists of Silicon sub-detectors and a Time Projection Chamber (TPC) equipped with micro-pattern gas detectors (MPGDs). Within the framework of the LCTPC collaboration, a Large Prototype (LP) TPC has been built as a demonstrator. This prototype has been equipped with Gas Electron Multiplier (GEM) modules and studied with electron beams of energies 1–6 GeV at the DESY test beam facility. The performance of the prototype detector and the extrapolation to the ILD TPC is presented here. In addition, ongoing optimisation studies and R&D activities in order to prepare the next GEM module iteration are discussed.

  8. Europa Imaging Highlights during GEM

    Science.gov (United States)

    1998-01-01

    During the two year Galileo Europa Mission (GEM), NASA's Galileo spacecraft will focus intensively on Jupiter's intriguing moon, Europa. This montage shows samples of some of the features that will be imaged during eight successive orbits. The images in this montage are in order of increasing orbit from the upper left (orbit 11) to the lower right (orbit 19).DESCRIPTIONS AND APPROXIMATE RESOLUTIONSTriple bands and dark spots1.6 kilometers/pixelConamara Chaos1.6 kilometers/pixelMannan'an Crater1.6 kilometers/ pixelCilix1.6 kilometers/pixelAgenor Linea and Thrace Macula2 kilometers/pixelSouth polar terrain2 kilometers/pixelRhadamanthys Linea1.6 kilometers/pixelEuropa plume search7 kilometers/pixel1. Triple bands and dark spots were the focus of some images from Galileo's eleventh orbit of Jupiter. Triple bands are multiple ridges with dark deposits along the outer margins. Some extend for thousands of kilometers across Europa's icy surface. They are cracks in the ice sheet and indicate the great stresses imposed on Europa by tides raised by Jupiter, as well as Europa's neighboring moons, Ganymede and Io. The dark spots or 'lenticulae' are spots of localized disruption.2. The Conamara Chaos region reveals icy plates which have broken up, moved, and rafted into new positions. This terrain suggests that liquid water or ductile ice was present near the surface. On Galileo's twelfth orbit of Jupiter, sections of this region with resolutions as high as 10 meters per picture element will be obtained.3. Mannann'an Crater is a feature newly discovered by Galileo in June 1996. Color and high resolution images (to 40 meters per picture element) from Galileo's fourteenth orbit of Jupiter will offer a close look at the crater and help characterize how impacts affect the icy surface of this moon.4. Cilix, a large mound about 1.5 kilometers high, is the center of Europa's coordinate system. Its concave top and what may be flow like features to the southwest of the mound are

  9. Precision meson spectroscopy. Diffractive production at COMPASS and development of a GEM-based TPC for PANDA

    Energy Technology Data Exchange (ETDEWEB)

    Weitzel, Quirin

    2008-09-24

    . Due to its excellent tracking capabilities for charged particles, a time projection chamber (TPC) has been proposed for the central tracker of PANDA. A continuous operation without ion gate is foreseen, which constitutes a novel development in high-rate particle physics experiments. Gas Electron Multiplier (GEM) foils offer an intrinsic ion back-flow suppression combined with high gains, and will therefore be used for gas amplification. A small-size GEM-TPC test chamber has been constructed during this thesis and commissioned using both X-rays and muons from cosmic-ray air-showers. From the latter data, a spatial resolution down to 140 {mu}m has been achieved. The detector has been operated stably for many months with Ar/CO{sub 2} (70/30) and at typical gas amplification factors of (5-10).10{sup 3}. (orig.)

  10. Precision meson spectroscopy. Diffractive production at COMPASS and development of a GEM-based TPC for PANDA

    International Nuclear Information System (INIS)

    Weitzel, Quirin

    2008-01-01

    ) has been proposed for the central tracker of PANDA. A continuous operation without ion gate is foreseen, which constitutes a novel development in high-rate particle physics experiments. Gas Electron Multiplier (GEM) foils offer an intrinsic ion back-flow suppression combined with high gains, and will therefore be used for gas amplification. A small-size GEM-TPC test chamber has been constructed during this thesis and commissioned using both X-rays and muons from cosmic-ray air-showers. From the latter data, a spatial resolution down to 140 μm has been achieved. The detector has been operated stably for many months with Ar/CO 2 (70/30) and at typical gas amplification factors of (5-10).10 3 . (orig.)

  11. Construction, test and commissioning of the triple-GEM tracking detector for COMPASS

    CERN Document Server

    Altunbas, M C; Dehmelt, K; Ehlers, J; Konorov, I; Gandi, A; Kappler, S; Ketzer, B; De Oliveira, R; Paul, S; Placci, Alfredo; Ropelewski, Leszek; Sauli, Fabio; Simon, F; Van Stenis, M

    2002-01-01

    The Small Area Tracking system of the COMPASS experiment at CERN includes a set of 20 large area, fast position-sensitive Gas Electron Multiplier (GEM) detectors, designed to reliably operate in the harsh radiation environment of the experiment. We describe in detail the design, choice of materials, assembly procedures and quality controls used to manufacture the devices. The test procedure in the laboratory, the performance in test beams and in the initial commissioning phase in the experiment are presented and discussed.

  12. X-Ray Polarimetry with GEMS

    Science.gov (United States)

    Strohmayer, Tod

    2011-01-01

    The polarization properties of cosmic X-ray sources are still largely unexplored. The Gravity and Extreme Magnetism SMEX (GEMS) will carry out the first sensitive X-ray polarization survey of a wide range of sources including; accreting compact objects (black holes and neutron stars), AGN, supernova remnants, magnetars and rotation-powered pulsars. GEMS employs grazing-incidence foil mirrors and novel time-projection chamber (TPC) polarimeters leveraging the photoelectric effect to achieve high polarization sensitivity in the 2 - 10 keV band. I will provide an update of the project status, illustrate the expected performance with several science examples, and provide a brief overview of the data analysis challenges

  13. Reliability of point-of-care hematocrit, blood gas, electrolyte, lactate and glucose measurement during cardiopulmonary bypass.

    NARCIS (Netherlands)

    Steinfelder-Visscher, J.; Weerwind, P.W.; Teerenstra, S.; Brouwer, René

    2006-01-01

    BACKGROUND: Recently, the GEM Premier blood gas analyser was upgraded to the GEM Premier 3000. In addition to pH, pCO2, pO2, Na+, K+, Ca2+, and hematocrit measurement, glucose and lactate can be measured on the GEM Premier 3000. In this prospective clinical study, the analytical performance of the

  14. Triple GEM detector sensitivity simulations with Geant4 for the CMS Forward Muon Upgrade at CERN LHC

    Science.gov (United States)

    Zenoni, Florian; CMS GEM Collaboration

    2015-04-01

    Triple Gas Electron Multiplier (GEM) detectors are being developed for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. After the second long LHC shutdown, their implementation will take place for the GE1/1 system in the 1 . 5 technology can improve the muon track reconstruction and identification capabilities of the forward detector. The Triple GEMs will work in a hostile radiation background (several hundreds of Hz/cm2) mostly made of photons, neutrons, electrons and positrons. To understand how this background could affect the detectors' functionality it is important to know the sensitivity to these kinds of radiation. The goal of this work is to estimate the sensitivity of Triple GEMs to background particles in the CMS cavern environment, thanks to the latest updates of GEANT4, a toolkit for the simulation of the passage of particles through matter.

  15. Analysis of Beam Test Data from UTA GEM Prototype Chambers with One-Bit Digital Readout System

    Science.gov (United States)

    Pray, Danrae

    2012-03-01

    Gas Electron Multiplier (GEM) technology is currently a strong candidate for a Digital Hadron Calorimeter to be implemented in an experiment in future accelerators such as the International Linear Collider. The University of Texas at Arlington High Energy Physics Group has been developing prototype GEM detectors which contain two layers of GEM foils. The team performed a two week long beam test of four prototype chambers with dimensions 30cm by 30cm at Fermi National Accelerator Laboratory in August of 2011. Three of these chambers were equipped with the one bit DCAL chip readout system jointly developed by Argonne National Laboratory and Fermi National Accelerator Laboratory teams. In this talk, we give an updated report of the results of the test beam data analysis of the GEM prototype detector functionality, responses to various particle types, efficiency dependence on threshold and high voltage, as well as the current/future studies that the UTA team is performing with the GEM detectors and DCAL readout system.

  16. Study of long-term operation of triple-GEM detectors for the high rate environment in CMS

    CERN Document Server

    Merlin, Jeremie Alexandre

    2013-01-01

    The CMS GEM collaboration is working on the possible instrumentation of the high-eta region of the CMS Endcap with Gas Electron Multiplier (GEM) detectors, a technology capable to sustain the hostile environment that will be encountered at the high-luminosity LHC. To ensure the long-term operation of large triple-GEM detectors in the CMS experiment, we are performing a set of studies in order to measure and understand the aging effect of triple-GEM Muon chambers. The aging includes all the processes that lead to a significant degradation of the performances of the detector gain drop, non-uniformity, dark current, discharges and resolution loss. The project is focused on monitoring continuously the response of the detector when irradiated by a source of Cs 137 at CERN in the Gamma Irradiation Facility (GIF). Moreover, the new technology employed for stretching the GEM foils, so called NS2, introduces new, carefully chosen materials and components in the detectors. Outgassing tests are performed in order to va...

  17. GEM detector performance with innovative micro-TPC readout in high magnetic field

    Science.gov (United States)

    Garzia, I.; Alexeev, M.; Amoroso, A.; Baldini Ferroli, R.; Bertani, M.; Bettoni, D.; Bianchi, F.; Calcaterra, A.; Canale, N.; Capodiferro, M.; Cassariti, V.; Cerioni, S.; Chai, J. Y.; Chiozzi, S.; Cibinetto, G.; Cossio, F.; Cotta Ramusino, A.; De Mori, F.; Destefanis, M.; Dong, J.; Evangelisti, F.; Evangelisti, F.; Farinelli, R.; Fava, L.; Felici, G.; Fioravanti, E.; Gatta, M.; Greco, M.; Lavezzi, L.; Leng, C. Y.; Li, H.; Maggiora, M.; Malaguti, R.; Marcello, S.; Melchiorri, M.; Mezzadri, G.; Mignone, M.; Morello, G.; Pacetti, S.; Patteri, P.; Pellegrino, J.; Pelosi, A.; Rivetti, A.; Rolo, M. D.; Savrié, M.; Scodeggio, M.; Soldani, E.; Sosio, S.; Spataro, S.; Tskhadadze, E.; Verma, S.; Wheadon, R.; Yan, L.

    2018-01-01

    Gas detector development is one of the pillars of the research in fundamental physics. Since several years, a new concept of detectors, called Micro Pattern Gas Detector (MPGD), allowed to overcome several problems related to other types of commonly used detectors, like drift chamber and micro strips detectors, reducing the rate of discharges and providing better radiation tolerance. Among the most used MPGDs are the Gas Electron Multipliers (GEMs). Invented by Sauli in 1997, nowadays GEMs have become an important reality for particle detectors in high energy physics. Commonly deployed as fast timing detectors and triggers, their fast response, high rate capability and high radiation hardness make them also suitable as tracking detectors. The readout scheme is one of the most important features in tracking technology. Analog readout based on the calculation of the center of gravity technique allows to overcome the limit imposed by digital pads, whose spatial resolution is limited by the pitch dimensions. However, the presence of high external magnetic fields can distort the electronic cloud and affect the performance. The development of the micro-TPC reconstruction method brings GEM detectors into a new prospective, improving significantly the spatial resolutionin presence of high magnetic fields. This innovative technique allows to reconstruct the 3-dimensional particle position, as Time Projection Chamber, but within a drift gap of a few millimeters. In these report, the charge centroid and micro-TPC methods are described in details. We discuss the results of several test beams performed with planar chambers in magnetic field. These results are one of the first developments of micro-TPC technique for GEM detectors, which allows to reach unprecedented performance in a high magnetic field of 1 T.

  18. Summary final report: Contract between the Japan atomic power company and the U.S. Department of Energy Improvement of core safety - study on GEM (III)

    Energy Technology Data Exchange (ETDEWEB)

    Burke, T.M.; Lucoff, D.M.

    1997-03-18

    This report provides a summary of activities associated with the technical exchange between representatives of the Japan Atomic Power Company (JAPC) and the United States Department of Energy (DOE) regarding the development and testing of Gas Expansion Modules (GEM) at the Fast Flux Test Facility (FFTF). Issuance of this report completes the scope of work defined in the original contract between JAPC and DOE titled ''Study on Improvement of Core Safety - Study on GEM (III).'' Negotiations related to potential modification of the contract are in progress. Under the proposed contract modification, DOE would provide an additional report documenting FFTF pump start tests with GEMs and answer additional JAPC questions related to core safety with and without GEMs.

  19. Summary final report: Contract between the Japan atomic power company and the U.S. Department of Energy Improvement of core safety - study on GEM (III)

    International Nuclear Information System (INIS)

    Burke, T.M.; Lucoff, D.M.

    1997-01-01

    This report provides a summary of activities associated with the technical exchange between representatives of the Japan Atomic Power Company (JAPC) and the United States Department of Energy (DOE) regarding the development and testing of Gas Expansion Modules (GEM) at the Fast Flux Test Facility (FFTF). Issuance of this report completes the scope of work defined in the original contract between JAPC and DOE titled ''Study on Improvement of Core Safety - Study on GEM (III).'' Negotiations related to potential modification of the contract are in progress. Under the proposed contract modification, DOE would provide an additional report documenting FFTF pump start tests with GEMs and answer additional JAPC questions related to core safety with and without GEMs

  20. Study of etching processes in the GEM detectors

    CERN Document Server

    Zavazieva, Darina

    2016-01-01

    Gaseous Electron Multiplier (GEM) detectors are known to operate stably at high gains and high particle fluxes. Though, at very high gains and fluxes it was observed that the insulating polyimide layer between the GEM electrodes gets etched, changing the original shape of the hole, and therefore varying the gain and the energy resolution of the detector. The idea of the project to observe degradation effect of the GEM foils during the Triple GEM detector operation in extreme conditions under X-ray radiation.

  1. Novel gas-based detection techniques

    International Nuclear Information System (INIS)

    Graaf, Harry van der

    2009-01-01

    This year we celebrate the 100th birthday of gaseous detectors: Hans Geiger operated the first gas-filled counter in Manchester in 1908. The thin wires, essential for obtaining gas amplification, have been replaced by Micro Pattern Gas Detectors (MPGDs): Micromegas (1995) and GEM (1996). In the GridPix detector, each of the grid holes of a MPGD is equipped with its own electronic readout channel in the form of an active pixel in suitable pixel CMOS chips. By means of MEMS technology, the grid has been integrated with the chip, forming a monolithic readout device for gas volumes. By applying a protection layer made of hydrogenated amorphous silicon, the chips can be made spark proof. New protection layers have been made of silicon nitride. The use of gas as detection material for trackers is compared to Si, and the issue of chamber aging is addressed. New developments are set out: the development of Micro Channel Plates, integrated on pixel chips, the development of electron emission foil, and the realization of TimePix-2: a general-purpose pixel chip with time and amplitude measurement, per pixel, of charge signals.

  2. Numerical simulation of microwave amplification in a plasma channel produced in a gas via multiphoton ionisation by a femtosecond laser pulse

    Energy Technology Data Exchange (ETDEWEB)

    Bogatskaya, A V; Popov, A M [P N Lebedev Physics Institute, Russian Academy of Sciences, Moscow (Russian Federation); Volkova, E A [D.V. Skobeltsyn Institute of Nuclear Physics, M.V. Lomonosov Moscow State University, Moscow (Russian Federation)

    2014-12-31

    This paper examines the evolution of a nonequilibrium plasma channel produced in xenon by a femtosecond KrF laser pulse. We demonstrate that such a channel can be used to amplify microwave pulses over times of the order of the relaxation time of the photoelectron energy spectrum in xenon. Using the slowly varying amplitude approximation, we analyse the propagation and amplification of an rf pulse in a plasma channel, in particular when the rf field influences the electron energy distribution function in the plasma. (interaction of laser radiation with matter. laser plasma)

  3. The Triple-GEM Project for the Phase 2 Upgrade of the CMS Muon System

    CERN Document Server

    Tytgat, Michael

    2014-01-01

    In view of the high-luminosity phase of the LHC, the CMS Collaboration is considering the use of Gas Electron Multiplier (GEM) detector technology for the upgrade of its muon system in the forward region. With their ability to handle the extreme particle rates expected in that area, such micro-pattern gas detectors can sustain a high performance and redundant muon trigger system. At the same time, with their excellent spatial resolution, they can improve the muon track reconstruction and identification capabilities of the forward detector, effectively combining tracking and triggering functions in one single device. The present status of the CMS GEM project will be reviewed, highlighting importants steps and achievements since the start of the R and D activities in 2009. The baseline design of the triple-GEM detectors proposed for installation in different stations of the CMS muon endcap system will be described, along with the associated frontend electronics and data-acquisition system. The expected impact o...

  4. Performance Verification of the Gravity and Extreme Magnetism Small Explorer GEMS X-Ray Polarimeter

    Science.gov (United States)

    Enoto, Teruaki; Black, J. Kevin; Kitaguchi, Takao; Hayato, Asami; Hill, Joanne E.; Jahoda, Keith; Tamagawa, Toru; Kanako, Kenta; Takeuchi, Yoko; Yoshikawa, Akifumi; hide

    2014-01-01

    olarimetry is a powerful tool for astrophysical observations that has yet to be exploited in the X-ray band. For satellite-borne and sounding rocket experiments, we have developed a photoelectric gas polarimeter to measure X-ray polarization in the 2-10 keV range utilizing a time projection chamber (TPC) and advanced micro-pattern gas electron multiplier (GEM) techniques. We carried out performance verification of a flight equivalent unit (1/4 model) which was planned to be launched on the NASA Gravity and Extreme Magnetism Small Explorer (GEMS) satellite. The test was performed at Brookhaven National Laboratory, National Synchrotron Light Source (NSLS) facility in April 2013. The polarimeter was irradiated with linearly-polarized monochromatic X-rays between 2.3 and 10.0 keV and scanned with a collimated beam at 5 different detector positions. After a systematic investigation of the detector response, a modulation factor greater than or equal to 35% above 4 keV was obtained with the expected polarization angle. At energies below 4 keV where the photoelectron track becomes short, diffusion in the region between the GEM and readout strips leaves an asymmetric photoelectron image. A correction method retrieves an expected modulation angle, and the expected modulation factor, approximately 20% at 2.7 keV. Folding the measured values of modulation through an instrument model gives sensitivity, parameterized by minimum detectable polarization (MDP), nearly identical to that assumed at the preliminary design review (PDR).

  5. Test and improvement of readout system based on APV25 chip for GEM detector

    International Nuclear Information System (INIS)

    Hu Shouyang; Jian Siyu; Zhou Jing; Shan Chao; Li Xinglong; Li Xia; Li Xiaomei; Zhou Yi

    2014-01-01

    Gas electron multiplier (GEM) is the most promising position sensitive gas detector. The new generation of readout electronics system includes APV25 front-end card, multi-purpose digitizer (MPD), VME controller and Linux-based acquisition software DAQ. The construction and preliminary test of this readout system were finished, and the ideal data with the system working frequency of 40 MHz and 20 MHz were obtained. The long time running test shows that the system has a very good time-stable ability. Through optimizing the software configuration and improving hardware quality, the noise level was reduced, and the signal noise ratio was improved. (authors)

  6. The Ozone Layer. UNEP/GEMS Environment Library No. 2.

    Science.gov (United States)

    United Nations Environment Programme, Nairobi (Kenya).

    Since the United Nations Environment Program (UNEP) was created, more than a dozen years ago, public understanding of the environmental issues confronting our planet has increased enormously. The Global Environment Monitoring System (GEMS) has provided several environmental assessments. The aim of the UNEP/GEMS Environment Library is to provide…

  7. Extending the ISC-GEM Global Earthquake Instrumental Catalogue

    Science.gov (United States)

    Di Giacomo, Domenico; Engdhal, Bob; Storchak, Dmitry; Villaseñor, Antonio; Harris, James

    2015-04-01

    After a 27-month project funded by the GEM Foundation (www.globalquakemodel.org), in January 2013 we released the ISC-GEM Global Instrumental Earthquake Catalogue (1900 2009) (www.isc.ac.uk/iscgem/index.php) as a special product to use for seismic hazard studies. The new catalogue was necessary as improved seismic hazard studies necessitate that earthquake catalogues are homogeneous (to the largest extent possible) over time in their fundamental parameters, such as location and magnitude. Due to time and resource limitation, the ISC-GEM catalogue (1900-2009) included earthquakes selected according to the following time-variable cut-off magnitudes: Ms=7.5 for earthquakes occurring before 1918; Ms=6.25 between 1918 and 1963; and Ms=5.5 from 1964 onwards. Because of the importance of having a reliable seismic input for seismic hazard studies, funding from GEM and two commercial companies in the US and UK allowed us to start working on the extension of the ISC-GEM catalogue both for earthquakes that occurred beyond 2009 and for earthquakes listed in the International Seismological Summary (ISS) which fell below the cut-off magnitude of 6.25. This extension is part of a four-year program that aims at including in the ISC-GEM catalogue large global earthquakes that occurred before the beginning of the ISC Bulletin in 1964. In this contribution we present the updated ISC GEM catalogue, which will include over 1000 more earthquakes that occurred in 2010 2011 and several hundreds more between 1950 and 1959. The catalogue extension between 1935 and 1949 is currently underway. The extension of the ISC-GEM catalogue will also be helpful for regional cross border seismic hazard studies as the ISC-GEM catalogue should be used as basis for cross-checking the consistency in location and magnitude of those earthquakes listed both in the ISC GEM global catalogue and regional catalogues.

  8. An aging study of a gas electron multiplier with micro-strip gas chamber readout

    CERN Document Server

    Miyamoto, J

    1999-01-01

    We have performed an aging study of a Gas Electron Multiplier (GEM) readout with a Micro-Strip Gas Chamber (MSGC). The GEM is constructed from Kapton and copper, and the MSGC is constructed from semiconductive glass and gold. When the detector (GEM+MSGC) is operated in an argon-dimethyl ether (DME) gas mixture and irradiated with a 5.4 keV photon beam, about 220 mC/cm of charge can be accumulated without degradation of the detector performance. This corresponds to about 20 years of operation at the LHC.

  9. PLC-controlled cryostats for the BlackGEM and MeerLICHT detectors

    Science.gov (United States)

    Raskin, Gert; Morren, Johan; Pessemier, Wim; Bloemen, Steven; Klein-Wolt, Marc; Roelfsema, Ronald; Groot, Paul; Aerts, Conny

    2016-08-01

    BlackGEM is an array of telescopes, currently under development at the Radboud University Nijmegen and at NOVA (Netherlands Research School for Astronomy). It targets the detection of the optical counterparts of gravitational waves. The first three BlackGEM telescopes are planned to be installed in 2018 at the La Silla observatory (Chile). A single prototype telescope, named MeerLICHT, will already be commissioned early 2017 in Sutherland (South Africa) to provide an optical complement for the MeerKAT radio array. The BlackGEM array consists of, initially, a set of three robotic 65-cm wide-field telescopes. Each telescope is equipped with a single STA1600 CCD detector with 10.5k x 10.5k 9-micron pixels that covers a 2.7 square degrees field of view. The cryostats for housing these detectors are developed and built at the KU Leuven University (Belgium). The operational model of BlackGEM requires long periods of reliable hands-off operation. Therefore, we designed the cryostats for long vacuum hold time and we make use of a closed-cycle cooling system, based on Polycold PCC Joule-Thomson coolers. A single programmable logic controller (PLC) controls the cryogenic systems of several BlackGEM telescopes simultaneously, resulting in a highly reliable, cost-efficient and maintenance-friendly system. PLC-based cryostat control offers some distinct advantages, especially for a robotic facility. Apart of temperature monitoring and control, the PLC also monitors the vacuum quality, the power supply and the status of the PCC coolers (compressor power consumption and temperature, pressure in the gas lines, etc.). Furthermore, it provides an alarming system and safe and reproducible procedures for automatic cool down and warm up. The communication between PLC and higher-level software takes place via the OPC-UA protocol, offering a simple to implement, yet very powerful interface. Finally, a touch-panel display on the PLC provides the operator with a user-friendly and robust

  10. The HadGEM2-ES implementation of CMIP5 centennial simulations

    Directory of Open Access Journals (Sweden)

    C. D. Jones

    2011-07-01

    Full Text Available The scientific understanding of the Earth's climate system, including the central question of how the climate system is likely to respond to human-induced perturbations, is comprehensively captured in GCMs and Earth System Models (ESM. Diagnosing the simulated climate response, and comparing responses across different models, is crucially dependent on transparent assumptions of how the GCM/ESM has been driven – especially because the implementation can involve subjective decisions and may differ between modelling groups performing the same experiment. This paper outlines the climate forcings and setup of the Met Office Hadley Centre ESM, HadGEM2-ES for the CMIP5 set of centennial experiments. We document the prescribed greenhouse gas concentrations, aerosol precursors, stratospheric and tropospheric ozone assumptions, as well as implementation of land-use change and natural forcings for the HadGEM2-ES historical and future experiments following the Representative Concentration Pathways. In addition, we provide details of how HadGEM2-ES ensemble members were initialised from the control run and how the palaeoclimate and AMIP experiments, as well as the "emission-driven" RCP experiments were performed.

  11. Gem and mineral identification using GL Gem Raman and comparison with other portable instruments

    Science.gov (United States)

    Culka, Adam; Hyršl, Jaroslav; Jehlička, Jan

    2016-11-01

    Several mainly silicate minerals in their gemstone varieties have been analysed by the Gem Raman portable system by Gemlab R&T, Vancouver, Canada, in order to ascertain the general performance of this relatively non-expensive tool developed exactly for the purpose of gemstone identification. The Raman spectra of gemstones acquired by this system have been subsequently critically compared with the data obtained by several other portable or handheld Raman instruments. The Raman spectra acquired with the Gem Raman instrument were typically of lesser quality when compared with the spectra taken by other instruments. Characteristic features such as steep baseline probably due to the fluorescence of the minerals, Raman bands much broader and therefore less resolved closely located Raman bands, and generally greater shifts of the band positions from the reference values were encountered. Some gemstone groups such as rubies did not provide useful Raman spectra at all. Nevertheless, general identification of gemstones was possible for a selection of gemstones.

  12. High- and low-pressure operation of the gas electron multiplier

    International Nuclear Information System (INIS)

    Bondar, A.; Buzulutskov, A.; Shekhtman, L.; Sauli, F.

    1998-01-01

    We have studied the operation of the gas electron multiplier (GEM) in gas mixtures Xe-CO 2 , Ar-CO 2 and CH 4 at different pressures varying from 0.1 to 5 atm. In Ar- and Xe-based mixtures, the maximum GEM gain considerably decreases with pressure, from a few hundreds at 1 atm to below 10 at 5 atm. Combined gain of GEM and the micro-strip gas chamber (MSGC) can exceed values of 10000 at 1 atm and 100 at 5 atm. High GEM gains, of above 1000, were obtained in CH 4 at low pressures. We have observed the effect of the avalanche confinement in GEM micro-holes, resulting in violation of the pressure scaling and in the possibility of GEM operation in pure noble gases. (author)

  13. Charge-transfer properties in the gas electron multiplier

    International Nuclear Information System (INIS)

    Han, Sanghyo; Kim, Yongkyun; Cho, Hyosung

    2004-01-01

    The charge transfer properties of a gas electron multiplier (GEM) were systematically investigated over a broad range of electric field configurations. The electron collection efficiency and the charge sharing were found to depend on the external fields, as well as on the GEM voltage. The electron collection efficiency increased with the collection field up to 90%, but was essentially independent of the drift field strength. A double conical GEM has a 10% gain increase with time due to surface charging by avalanche ions whereas this effect was eliminated with the cylindrical GEM. The positive-ion feedback is also estimated. (author)

  14. Gems of combinatorial optimization and graph algorithms

    CERN Document Server

    Skutella, Martin; Stiller, Sebastian; Wagner, Dorothea

    2015-01-01

    Are you looking for new lectures for your course on algorithms, combinatorial optimization, or algorithmic game theory?  Maybe you need a convenient source of relevant, current topics for a graduate student or advanced undergraduate student seminar?  Or perhaps you just want an enjoyable look at some beautiful mathematical and algorithmic results, ideas, proofs, concepts, and techniques in discrete mathematics and theoretical computer science?   Gems of Combinatorial Optimization and Graph Algorithms is a handpicked collection of up-to-date articles, carefully prepared by a select group of international experts, who have contributed some of their most mathematically or algorithmically elegant ideas.  Topics include longest tours and Steiner trees in geometric spaces, cartograms, resource buying games, congestion games, selfish routing, revenue equivalence and shortest paths, scheduling, linear structures in graphs, contraction hierarchies, budgeted matching problems, and motifs in networks.   This ...

  15. Portable XRF: A Tool for the Study of Corundum Gems

    Directory of Open Access Journals (Sweden)

    Barone Germana

    2017-09-01

    Full Text Available Origin of gemstones is a key aspect not only in gemological field but also in Cultural Heritage studies, for the correct evaluation of precious artifacts. The studies on gems require the application of non-invasive and non-destructive methods; among them, portable spectroscopic techniques has been demonstrated as powerful tools, providing a fingerprint of gems for origin and provenance determination. In this study, portable XRF spectroscopy has been applied to test the potential of the technique for the origin determination of corundum gems. The obtained results allowed distinguishing natural and synthetic rubies and sapphires.

  16. Design and Construction of a First Prototype Muon Tomography System with GEM Detectors for the Detection of Nuclear Contraband

    CERN Document Server

    AUTHOR|(CDS)2074269; Grasso, L; Locke, J B; Quintero, A; Mitra, D

    2009-01-01

    Current radiation portal monitors at sea ports and international borders that employ standard radiation detection techniques are not very sensitive to nuclear contraband that is well shielded to absorb emanating radiation. Muon Tomography (MT) based on the measurement of multiple scattering of atmospheric cosmic ray muons traversing cargo or vehicles that contain high-Z material is a promising passive interrogation technique for solving this problem. We report on the design and construction of compact Micro-Pattern Gas Detectors for a small prototype MT station. This station will employ 10 tracking stations based on 30cm x 30cm low-mass triple-GEM detectors with 2D readout. Due to the excellent spatial resolution of GEMs it is sufficient to use a gap of only a few cm between tracking stations. Together with the compact size of the GEM detectors this allows the GEM MT station to be an order of magnitude more compact than MT stations using traditional drift tubes. We present details of the production and assemb...

  17. Development of the DAQ System of Triple-GEM Detectors for the CMS Muon Spectrometer Upgrade at LHC

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00387583

    The Gas Electron Multiplier (GEM) upgrade project aims at improving the performance of the muon spectrometer of the Compact Muon Solenoid (CMS) experiment which will suffer from the increase in luminosity of the Large Hadron Collider (LHC). After a long technical stop in 2019-2020, the LHC will restart and run at a luminosity of 2 × 1034 cm−2 s−1, twice its nominal value. This will in turn increase the rate of particles to which detectors in CMS will be exposed and affect their performance. The muon spectrometer in particular will suffer from a degraded detection efficiency due to the lack of redundancy in its most forward region. To solve this issue, the GEM collaboration proposes to instrument the first muon station with Triple-GEM detectors, a technology which has proven to be resistant to high fluxes of particles. Within the GEM collaboration, the Data Acquisition (DAQ) subgroup is in charge of the development of the electronics and software of the DAQ system of the detectors. This thesis presents th...

  18. Production and performance of LHCb triple-GEM detectors equipped with the dedicated CARDIAC-GEM front-end electronics

    Energy Technology Data Exchange (ETDEWEB)

    Alfonsi, M. [Laboratori Nazionali di Frascati - INFN (Italy)]. E-mail: matteo.alfonsi@lnf.infn.it; Bencivenni, G. [Laboratori Nazionali di Frascati - INFN (Italy); Bonivento, W. [Sezione INFN di Cagliari (Italy); Cardelli, E. [Sezione INFN di Cagliari (Italy); Cardini, A. [Sezione INFN di Cagliari (Italy); De Simone, P. [Laboratori Nazionali di Frascati - INFN (Italy); Domenici, D. [Laboratori Nazionali di Frascati - INFN (Italy); Murtas, F. [Laboratori Nazionali di Frascati - INFN (Italy); Pinci, D. [Sezione INFN di Roma 1 (Italy); Poli Lener, M. [Laboratori Nazionali di Frascati - INFN (Italy); Raspino, D. [Sezione INFN di Cagliari (Italy); Saitta, B. [Sezione INFN di Cagliari (Italy)

    2007-03-01

    The production of the triple-GEM detectors for the innermost region of the first muon station of the LHCb experiment has started in February 2006, and is foreseen to be completed by the end of July. The final design of the detector and the construction procedure and tools, as well as the quality controls are defined. The performances of each detector, composed by two triple-GEM chambers equipped with dedicated CARDIAC-GEM front-end electronics, are studied with a cosmic ray telescope. The cosmic ray telescope has been set up including all the final off-detector components.

  19. An X-ray imaging device based on a GEM detector with delay-line readout

    Science.gov (United States)

    Zhou, Yi; Li, Cheng; Sun, Yong-Jie; Shao, Ming

    2010-01-01

    An X-ray imaging device based on a triple-GEM (Gas Electron Multiplier) detector, a fast delay-line circuit with 700 MHz cut-off frequency and two dimensional readout strips with 150 μm width on the top and 250 μm width on the bottom, is designed and tested. The localization information is derived from the propagation time of the induced signals on the readout strips. This device has a good spatial resolution of 150 μm and works stably at an intensity of 105 Hz/mm2 with 8 keV X-rays.

  20. Single Electron Detection in Quadruple-GEM Detector with Pad Readout

    Energy Technology Data Exchange (ETDEWEB)

    Va' vra, Jaroslav

    2001-03-07

    Using a system of four GEMs operating in tandem and coupled to pad readout, we have demonstrated the detection of single electrons in ethane at 1 bar. The paper presents measurements of single electron pulse height distributions, total gas gain measurement and calculation, pad-to-pad cross-talk, quenching capability, high rate capability, charging effects, etc. We describe the overall operational experience, including addition of a gaseous photocathode, TMAE, and compare it to the SLD CRID single-electron detector [1], which has been operational during the past decade.

  1. A fast triple-GEM detector for high-rate charged-particle triggering

    Energy Technology Data Exchange (ETDEWEB)

    Bencivenni, G.; Bonivento, W.; Bosio, C.; Cardini, A. E-mail: alessandro.cardini@cern.ch; Felici, G.; Lai, A.; Murtas, F.; Pinci, D.; Saitta, B.; Satta, L.; Valente, P

    2002-02-01

    Triple-GEM detectors with pad readout has been tested at the CERN PS T11 Hadron Beam Facility. A time distribution RMS of 6 ns has been obtained with an Ar/CO{sub 2}/CF{sub 4} (60/20/20) gas mixture, achieving a substantial improvement with respect to Ar/CO{sub 2} (70/30), where an RMS of 10 ns was obtained. This resulted in an efficiency of about 96% in a 25 ns time-window (and a total efficiency of 99.7%), suggesting that these detectors could be interesting devices for triggering at the typical LHC interaction rate.

  2. Tomographic capabilities of the new GEM based SXR diagnostic of WEST

    Czech Academy of Sciences Publication Activity Database

    Jardin, A.; Mazon, D.; O’Mullane, M.; Mlynář, Jan; Löffelmann, Viktor; Imríšek, Martin; Chernyshova, M.; Czarski, T.; Kasprowicz, G.; Wojenski, A.; Bourdelle, C.; Malard, P.

    2016-01-01

    Roč. 11, July (2016), č. článku C07006. ISSN 1748-0221. [International Conference Frontiers in Diagnostics fix Technologies (ICFDT4). Frascati (Rome), 30.03.2016-01.04.2016] Institutional support: RVO:61389021 Keywords : GEM * SXR * tomography * plasma diagnostics Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: 2.11 Other engineering and technologies Impact factor: 1.220, year: 2016 http://iopscience.iop.org/article/10.1088/1748-0221/11/07/C07006/pdf

  3. Wits Post Graduate Symposium Poster - iGEM

    CSIR Research Space (South Africa)

    Millroy, L

    2010-08-01

    Full Text Available This document is a poster providing details of the 2010 International Genetically Engineered Machines (iGEM) competition. The origins of the competition, as well as criteria, judging, sponsors, topic and team, are briefly described....

  4. SYNTHESIS AND POLYMERIZATION OF GEM-METHYL(VINYLBENZYL)TETRACHLOROCYCLOTRIPHOSPHAZENE

    NARCIS (Netherlands)

    BOSSCHER, G; VANDEGRAMPEL, JC

    A new styrene-substituted chlorocyclotriphosphazene, gem-methyl(vinylbenzyl) tetrachlorocyclotriphosphazene, has been prepared from vinylbenzylmagnesium chloride and hexachlorocyclotriphosphazene. The organosubstituted chlorocyclotriphosphazene has been used in radical homo- and copolymerization

  5. International Genetically Engineered Machine (iGEM) Competition

    CSIR Research Space (South Africa)

    Sparrow, RW

    2010-07-01

    Full Text Available iGEM, the International Genetically Engineered Machine competition, is an initiative from MIT and has become the premiere undergraduate synthetic biology competition. The competing teams consist of students who work on a synthetic biology project...

  6. Performance of an optical readout GEM-based TPC

    International Nuclear Information System (INIS)

    Margato, L.M.S.; Fraga, F.A.F.; Fetal, S.T.G.; Fraga, M.M.F.R.; Balau, E.F.S.; Blanco, A.; Marques, R. Ferreira; Policarpo, A.J.P.L

    2004-01-01

    We report on the operation of a GEM-based small TPC using an optical readout. The detector was operated with a mixture of Ar+CF 4 using 5.48 MeV alpha particles obtained from a 241 Am source and the GEM scintillation was concurrently read by a CCD camera and a photomultiplier. Precision collimators were used to define the track orientation. Qualitative results on the accuracy of the track angle, length and charge deposition measurements are presented

  7. Embedded controller for GEM detector readout system

    Science.gov (United States)

    Zabołotny, Wojciech M.; Byszuk, Adrian; Chernyshova, Maryna; Cieszewski, Radosław; Czarski, Tomasz; Dominik, Wojciech; Jakubowska, Katarzyna L.; Kasprowicz, Grzegorz; Poźniak, Krzysztof; Rzadkiewicz, Jacek; Scholz, Marek

    2013-10-01

    This paper describes the embedded controller used for the multichannel readout system for the GEM detector. The controller is based on the embedded Mini ITX mainboard, running the GNU/Linux operating system. The controller offers two interfaces to communicate with the FPGA based readout system. FPGA configuration and diagnostics is controlled via low speed USB based interface, while high-speed setup of the readout parameters and reception of the measured data is handled by the PCI Express (PCIe) interface. Hardware access is synchronized by the dedicated server written in C. Multiple clients may connect to this server via TCP/IP network, and different priority is assigned to individual clients. Specialized protocols have been implemented both for low level access on register level and for high level access with transfer of structured data with "msgpack" protocol. High level functionalities have been split between multiple TCP/IP servers for parallel operation. Status of the system may be checked, and basic maintenance may be performed via web interface, while the expert access is possible via SSH server. System was designed with reliability and flexibility in mind.

  8. Gene amplification in carcinogenesis

    Directory of Open Access Journals (Sweden)

    Lucimari Bizari

    2006-01-01

    Full Text Available Gene amplification increases the number of genes in a genome and can give rise to karyotype abnormalities called double minutes (DM and homogeneously staining regions (HSR, both of which have been widely observed in human tumors but are also known to play a major role during embryonic development due to the fact that they are responsible for the programmed increase of gene expression. The etiology of gene amplification during carcinogenesis is not yet completely understood but can be considered a result of genetic instability. Gene amplification leads to an increase in protein expression and provides a selective advantage during cell growth. Oncogenes such as CCND1, c-MET, c-MYC, ERBB2, EGFR and MDM2 are amplified in human tumors and can be associated with increased expression of their respective proteins or not. In general, gene amplification is associated with more aggressive tumors, metastases, resistance to chemotherapy and a decrease in the period during which the patient stays free of the disease. This review discusses the major role of gene amplification in the progression of carcinomas, formation of genetic markers and as possible therapeutic targets for the development of drugs for the treatment of some types of tumors.

  9. GEM Operation in High-Pressure CF4: Studies of Charge and Scintillation Properties

    Science.gov (United States)

    da Luz, Hugo Natal; Conceicao, Ana Sofia; Veloso, JoÃo F. C. A.; dos Santos, Joaquim M. F.; Bento, AntÓnio C. S. S. M.; Mir, Jamil A.; Ferreira, LuÍs F. Requicha

    2009-06-01

    Tetrafluoromethane (CF4) combined with Helium-3 is widely used as the filling gas for neutron detectors. CF4 is generally known as an efficient gas for proton and tritium stopping, as well as a medium with low gamma sensitivity. Filling pressures above 2.5 bar are needed to achieve detector position resolutions below 1 mm. In this work, we have studied the performance of a single-GEM operating in CF4 in the pressure range of 1.0 to 2.5 bar and shown that it is possible to achieve gains one order of magnitude higher than what is needed for thermal neutron detection. Charge gains of 1.6 times 104 and 400 are reached at pressures of 1.0 and 2.5 bar, respectively, indicating good properties for this purpose. In opposition to gases with higher scintillation efficiency such as xenon, GEM scintillation readout with VUV-sensitive avalanche photodiodes results in gains that are less than one order of magnitude higher than those obtained with charge readout, delivering similar energy resolutions.

  10. Social amplification of risk

    International Nuclear Information System (INIS)

    Kasperson, R.E.; Renn, O.; Slovic, P.; Kasperson, J.X.; Emani, S.

    1989-01-01

    The risks associated with radioactive and other hazardous waste disposal may be expected to interact with societal processes to enlarge or attenuate the consequences of risks and risk events. This article summarizes a conceptual framework that depicts the social amplification of risk. Using a data base of 128 hazard events that have occurred largely over the past ten years, the authors examine the role of physical consequences, media coverage, and public perceptions of risk in generating social and economic impacts. The analysis concludes that social amplification processes substantially shape the nature and magnitude of those impacts but also that such social amplification appears to be systematically related to characteristics of the risks and risk events

  11. Inpatient geriatric evaluation and management units (GEMs) in the veterans health system: diamonds in the rough?

    Science.gov (United States)

    Wieland, D; Rubenstein, L Z; Hedrick, S C; Reuben, D B; Buchner, D M

    1994-09-01

    Research suggests that inpatient geriatric evaluation and management units (GEMs), which undertake interdisciplinary diagnosis to improve the health of frail elderly patients, are effective. The Department of Veterans Affairs (VA) helped pioneer U.S. GEMs and mandates that every facility shall have a GEM by 1996. We conducted a population survey of VA GEMs in 1991 to assess their dissemination. Various organizational and performance characteristics of GEMs were entered in a data base derived from a piloted questionnaire and administrative records. Basic criteria from consensus reports were used to classify and compare "standard" and "nonstandard" GEMs. The criteria covered performance of assessment, team structure, patient selection, GEM location, and treatment functions. We analyzed the effect of GEM type and other factors on length of stay and placement. Reasons for closure of GEMs inactive in 1991 were recovered, and GEMs active in 1991 but later closed are described. As of 1991, 41 of 73 GEMs were classified as standard, and 32 nonstandard. Standard compared to nonstandard GEMs had shorter stays (25.4 vs 69.9 days; p home discharge rates (63.4% vs 40%; p nursing home placement rates (19.1% vs 40.3%; p closure. Additional work is needed to monitor GEM proliferation, implementation, and performance in and out of the VA system.

  12. For fashion and health (coloring of gems)

    International Nuclear Information System (INIS)

    Umeda, Iwao

    1998-01-01

    Artificial coloration of colorless jewel grade diamonds can be made by fast neutron irradiation using a research reactor or high energy electron beam bombardment by a linear accelerator. The irradiated color diamonds are from blue to green. After irradiation, the blue-green diamonds change color to yellow or orange by subsequent annealing using an electric furnace. The colored diamond hue depends on the treatment conditions. Fancy hue can be produced under some suitable conditions. Some special absorption bands in the spectrum obtained by a spectrophotometer can discriminate artificially colored diamonds from natural fancy color diamonds. Diamonds become to be radioactive immediately after irradiation by a reactor, but the radioactivity decay rapidly and become safe after a month. Some imported gems without diamond as blue topaz etc. are sometimes discovered to be radioactive artificially. Cultured pearls are covered by 0.4 mm thick nacreous layer on the pearl nucleus made of fresh-water unionidae thick shell. White pearls turn color to silver by 60 Co γ-ray irradiation. The pearl nucleus contained Mn turns color to brown by irradiation and absorbs red light from reflection on the surface, whereas the nacreous layer is little color change by irradiation because of small quantity of Mn and remains the luster. White pearls turn beautiful blue-silver of like natural color pearls seemingly, by γ-ray irradiation in suitable solution. Cubic zirconia made from ZrO 2 is a man-made colorless crystal looked like a diamond. The crystals turn color to orange by irradiation. (J.P.N)

  13. Development and studies of a time projection chamber with GEMs

    CERN Document Server

    Kaminski, J; Bieser, F; Janssen, M; Kappler, S; Ledermann, B; Müller, T; Ronan, M; Wienemann, P

    2004-01-01

    Future high-energy physics experiments will have stringent requirements on the quality of their central tracking systems. In order to evaluate whether a Time Projection Chamber (TPC) in combination with a Micro-Pattern Gas Amplification stage can meet these demands, a small cylindrical prototype has been equipped with two Gas Electron Multipliers (OEMs) and micropads connected to highly integrated front-end electronics. In earlier tests with this system in high-rate particle beams - but without magnetic field - at the Proton-Synchrotron at CERN, high efficiencies and good single-pad-row spatial resolutions could be demonstrated. We now present complementary measurements with this system in high magnetic fields up to 5 T at DESY (Hamburg, Germany). Detailed results are given for the spatial resolution dependence on parameters such as drift distance, effective gas gain and magnetic field. Transverse single- pad-row spatial resolution was found to be as low as (53 plus or minus 5) urn and a previously published ...

  14. On soliton amplification

    Science.gov (United States)

    Leibovich, S.; Randall, J. D.

    1979-01-01

    The paper considers a modified Korteweg-de Vries equation that permits wave amplification or damping. A 'terminal similarity' solution is identified for large times in amplified systems. Numerical results are given which confirm that the terminal similarity solution is a valid local approximation for mu t sufficiently large and positive, even though the approximation is not uniformly valid in space.

  15. Biomaterials in light amplification

    Science.gov (United States)

    Mysliwiec, Jaroslaw; Cyprych, Konrad; Sznitko, Lech; Miniewicz, Andrzej

    2017-03-01

    Biologically produced or inspired materials can serve as optical gain media, i.e. they can exhibit the phenomenon of light amplification. Some of these materials, under suitable dye-doping and optical pumping conditions, show lasing phenomena. The emerging branch of research focused on obtaining lasing action in highly disordered and highly light scattering materials, i.e. research on random lasing, is perfectly suited for biological materials. The use of biomaterials in light amplification has been extensively reported in the literature. In this review we attempt to report on progress in the development of biologically derived systems able to show the phenomena of light amplification and random lasing together with the contribution of our group to this field. The rich world of biopolymers modified with molecular aggregates and nanocrystals, and self-organized at the nanoscale, offers a multitude of possibilities for tailoring luminescent and light scattering properties that are not easily replicated in conventional organic or inorganic materials. Of particular importance and interest are light amplification and lasing, or random lasing studies in biological cells and tissues. In this review we will describe nucleic acids and their complexes employed as gain media due to their favorable optical properties and ease of manipulation. We will report on research conducted on various biomaterials showing structural analogy to nucleic acids such as fluorescent proteins, gelatins in which the first distributed feedback laser was realized, and also amyloids or silks, which, due to their dye-doped fiber-like structure, allow for light amplification. Other materials that were investigated in that respect include polysaccharides, like starch exhibiting favorable photostability in comparison to other biomaterials, and chitosan, which forms photonic crystals or cellulose. Light amplification and random lasing was not only observed in processed biomaterials but also in living

  16. High spatial and time resolutions with gas ionization detectors

    International Nuclear Information System (INIS)

    Pouthas, J.

    2001-09-01

    This document presents the principles and the characteristics of the gaseous ionisation detectors used in position and timing measurements. The first two parts recall the main notions (electron and ion motions, gaseous amplification, signal formation) and their applications to the proportional counter and the wire chamber. The explanation of the signal formation makes use of the Ramo theorem. The third part is devoted to the different types of wire chambers: drift or cathode strip chambers, TPC (time projection chamber). Some aspects on construction and ageing are also presented. Part 4 is on the detectors in which the multiplication is performed by a 'Parallel Plate' system (PPAC, Pestov counter). Special attention is paid to the RPCs (Resistive Plate Chambers) and their timing resolutions. Part 5 concentrates on 'Micro-pattern detectors' which use different kinds of microstructure for gaseous amplification. The new detectors MICROMEGAS, CAT (compteur a trous) and GEM (gas electron multiplier) and some of their applications are presented. The last part is a bibliography including some comments on the documents. (author)

  17. Conceptual design and development of GEM based detecting system for tomographic tungsten focused transport monitoring

    Science.gov (United States)

    Chernyshova, M.; Czarski, T.; Malinowski, K.; Kowalska-Strzęciwilk, E.; Poźniak, K.; Kasprowicz, G.; Zabołotny, W.; Wojeński, A.; Kolasiński, P.; Mazon, D.; Malard, P.

    2015-10-01

    Implementing tungsten as a plasma facing material in ITER and future fusion reactors will require effective monitoring of not just its level in the plasma but also its distribution. That can be successfully achieved using detectors based on Gas Electron Multiplier (GEM) technology. This work presents the conceptual design of the detecting unit for poloidal tomography to be tested at the WEST project tokamak. The current stage of the development is discussed covering aspects which include detector's spatial dimensions, gas mixtures, window materials and arrangements inside and outside the tokamak ports, details of detector's structure itself and details of the detecting module electronics. It is expected that the detecting unit under development, when implemented, will add to the safe operation of tokamak bringing the creation of sustainable nuclear fusion reactors a step closer. A shorter version of this contribution is due to be published in PoS at: 1st EPS conference on Plasma Diagnostics

  18. Characterization of the water diffusion in GEM foil material

    Science.gov (United States)

    Benussi, L.; Bianco, S.; Saviano, G.; Muhammad, S.; Piccolo, D.; Raffone, G.; Caponero, M.; Passamonti, L.; Pierluigi, D.; Russo, A.; Primavera, F.; Cerbelli, S.; Lalli, A.; Valente, M.; Ferrini, M.; Teissandier, B.; Taborelli, M.; Parvis, M.; Grassini, S.; Tirilló, J.; Sarasini, F.; Franchi, A. V.

    2018-02-01

    Systematic studies on the GEM foil material are performed to measure the moisture diffusion rate and saturation level. These studies are important because the presence of this compound inside the detector' s foil can possibly change its mechanical and electrical properties, and in such a way, the detector performance can be affected. To understand this phenomenon, a model is developed with COMSOL Multiphysics v. 4.3 [1], which described the adsorption and diffusion within the geometry of GEM foil, the concentration profiles and the time required to saturate the foil. The COMSOL model is verified by experimental observations on a GEM foil sample. This note will describe the model and its experimental verification results.

  19. GEMs with Double Layred Micropattern Electrodes and their Applications

    CERN Document Server

    Di Mauro, A.; Nappi, E.; Oliveira, R.; Peskov, V.; Pietropaolo, F.; Picchi, P.

    We have developed and tested several new designs of GEM detectors with micropattern electrodes manufactured by microelectronic technology. In one design, the inner layer of the detector electrode consists of thin metallic strips and the outer layer is made of a resistive grid manufactured by a screen printing technology. In other designs, the electrodes were made of metallic strips fed by HV via micro-resistors manufactured by a screen printing technology. Due to these features, the new detectors have several important advantages over conventional GEMs or ordinary thick GEMs. For example, the resistive grid (in the first design) and the screen printed resistors (in other designs) limited the current in case of discharges, making these detectors intrinsically spark-protected. We will here describe our tests with the photosensitive versions of these detectors (coated with CsI layers) and the efforts of implementing them in several applications. In particular, we will focus on our activity towards the ALICE RICH...

  20. CMS GEM detector material study for the HL-LHC

    CERN Document Server

    Muhammad, Saleh

    2017-01-01

    A study on the Gaseous Electron Multiplier (GEM) foil material is performed to determine the moisture diffusion rate and saturation level and the moisture effects on its mechanical properties. The study is focused on the foil contact with ambient air and moisture to determine the value of the diffusion coefficient of water in the detector polyimide. The presence of water inside the detector foil can determine the changes in its mechanical and electrical properties. A simulated model is developed by taking into account the real GEM foil (hole dimensions, shapes and material), which describes the adsorption on a sample. This work describes the model, its experimental verification, the water diffusion within the entire sheet geometry of the GEM foil, thus gaining concentration profiles and the time required to saturate the system and the effects on the mechanical properties.

  1. [Two Turkish manuscripts on gems (jauhar) and the treatment by means of gems].

    Science.gov (United States)

    Kutlar, F S

    2001-01-01

    Literary works of the genre called cevâhir-nâme or cevher-nâme are written in order to give information on how gems (cevher-jauhar) are formed, where they are found, their estimated values, how to distinguish them from the imitations, what their particular colours are and on their uses and harmful effects. These literary works are sometimes titled in accordance with the genre they belong to and sometimes they are given different titles. The literary works dealing with the subject of cevher are mostly written in prose and only a few of them are in verse. The Turkish versions of cevâhir-nâme texts started to be written in the 15th century. These texts, covering the earlier knowledge of medicine, give information on gems and perfumes; how they effect human health; and the way they should be used in medical treatment. Therefore, these texts should be discussed in relation with their place in the history of Turkish science. Two cevâhir-nâmes, which were translated into Turkish by Mustafâ bin Seydî and Za'îfî in the 15th and 16th centuries are still available. The translations by Mustafâ bin Seydî and Za'îfî, did not only convey the classical and medieval knowledge on cevhers to the contemporary readers, but they also confirm the fact that this information was a part of the Ottoman social life.

  2. HydroGEM, a hydrogen fuelled utility vehicle. Case study

    International Nuclear Information System (INIS)

    Hoevenaars, A.J.; Kraaij, G.J.; De Bruijne, M.; Weeda, M.

    2010-02-01

    This report describes the conversion of a Global Electric Motorcars (GEM, a Chrysler company) electric utility vehicle into a Fuel Cell Vehicle called HydroGEM, at the Energy research Centre of the Netherlands (ECN). The report is prepared as a case study within the framework of Task 18 on 'Evaluation of Integrated Hydrogen Systems' of the IEA Hydrogen Implementing Agreement. The vehicle's fuel cell system was designed in 2005, manufactured and built into the vehicle in 2006 and operated from 2007 onwards. The design-choices, assembly, operation and maintenance-issues are presented and discussed.

  3. Synthesis and Biological Evaluation of Glycosidase Inhibitors: gem-Difluoromethylenated Nojirimycin Analogues

    DEFF Research Database (Denmark)

    Bols, Mikael; Wang, Ruo-Wen; Qiu, Xiao-Long

    2006-01-01

    In our ongoing program aimed at the design, synthesis, and biological evaluation of novel gem-difluoromethylenated glycosidase inhibitors, gem-4,4-difluoromethylenated iminosugars (5-9) were synthesized. The biological evaluation of these synthetic iminosugars showed that the gem...

  4. Investigation of the "Escalator Effect" in the Kilmore East Fire of February, 2009 using GEM-AQ

    Science.gov (United States)

    Beale, J. L.; Semeniuk, K.; Lupu, A.; Kaminski, J. W.; McConnell, J. C.; O'Neill, N. T.; Glatthor, N.; Höpfner, M.; Palmer, P. I.; Tost, H.

    2012-12-01

    In early February, 2009, Southeast Australia was swept by intense bush fires which burned an area of about 3000 km2. Combustion products such as C2H2, HCN and HCOOH were observed in the UTLS region a few days later by MIPAS on the ENVISAT satellite. In addition, the OSIRIS instrument on the ODIN spacecraft has attributed aerosol measurements to products of the burning and lifting while the MLS instrument on AURA measured high values of CO for several weeks after the fire. This study is a continuation of the study by Glatthor et al (2012) which compared MIPAS observations to a high-resolution model run of the Global Environmental Multiscale with Air Quality (GEM-AQ) model. There is generally good agreement between the modelling and the observations, but there is still uncertainty as to whether the lifting of material into the UTLS by the fire process can be considered pyroconvection, or if it is due to the diabatic heating and lifting of the aerosol produced in the burning process (the "escalator effect"), or both. One limitation of our earlier study was the injection process of burning species and the lack of radiatively and chemically active aerosols within GEM-AQ. In this study we add black carbon (BC) and organic carbon (OC) estimates as part of the burning process and assess their role in the lifting of the biomass-burning material. The work described here uses GEM version 3.3.2. The gas-phase chemistry consists of detailed reactions of Ox, NOx, HOx, CO, CH4, NMVOCs, halocarbons, ClOx and BrO. We have recently added elements of the Global Modal-aerosol eXtension (GMXe) scheme to address aerosol microphysics and gas-aerosol partitioning. GEM-AQ is a global general circulation model based on the GEM model developed by the Meteorological Service of Canada for operational weather forecasting with on-line air quality and chemistry. It can be run with a global variable (GV) grid where the core has uniform grid spacing and the exterior grid expands. Our simulations

  5. Gas

    International Nuclear Information System (INIS)

    1996-01-01

    The French government has decided to modify the conditions of extension of local natural gas authorities to neighbouring districts. The European Union is studying the conditions of internal gas market with the objective of more open markets although considering public service requirements

  6. Construction and Performance of Large-Area Triple-GEM Prototypes for Future Upgrades of the CMS Forward Muon System

    CERN Document Server

    AUTHOR|(CDS)2068936; Marinov, A.; Zaganidis, N.; Ban, Y.; Cai, J.; Teng, H.; Mohapatra, A.; Moulik, T.; Abbrescia, M.; Colaleo, A.; de Robertis, G.; Loddo, F.; Maggi, M.; Nuzzo, S.; Tupputi, S.A.; Benussi, L.; Bianco, S.; Colafranceschi, S.; Piccolo, D.; Raffone, G.; Saviano, G.; Bagliesi, M.G.; Cecchi, R.; Magazzu, G.; Oliveri, E.; Turini, N.; Fruboes, T.; Abbaneo, D.; Armagnaud, C.; Aspell, P.; Bally, S.; Berzano, U.; Bos, J.; Bunkowski, K.; Chatelain, J.P.; Christiansen, J.; Conde Garcia, A.; David, E.; De Oliveira, R.; Duarte Pinto, S.; Ferry, S.; Formenti, F.; Franconi, L.; Marchioro, A.; Mehta, K.; Merlin, J.; Nemallapudi, M.V.; Postema, H.; Rodrigues, A.; Ropelewski, L.; Sharma, A.; Smilkjovic, N.; Villa, M.; Zientek, M.; Gutierrez, A.; Karchin, P.E.; Gnanvo, K.; Hohlmann, M.; Staib, M.J.

    2011-01-01

    At present, part of the forward RPC muon system of the CMS detector at the CERN LHC remains uninstrumented in the high-\\eta region. An international collaboration is investigating the possibility of covering the 1.6 < |\\eta| < 2.4 region of the muon endcaps with large-area triple-GEM detectors. Given their good spatial resolution, high rate capability, and radiation hardness, these micro-pattern gas detectors are an appealing option for simultaneously enhancing muon tracking and triggering capabilities in a future upgrade of the CMS detector. A general overview of this feasibility study will be presented. The design and construction of small (10\\times10 cm2) and full-size trapezoidal (1\\times0.5 m2) triple-GEM prototypes will be described. During detector assembly, different techniques for stretching the GEM foils were tested. Results from measurements with x-rays and from test beam campaigns at the CERN SPS will be shown for the small and large prototypes. Preliminary simulation studies on the expected...

  7. The Greenhouse Gases. UNEP/GEMS Environment Library No. 1.

    Science.gov (United States)

    United Nations Environment Programme, Nairobi (Kenya).

    Since the United Nations Environment Program (UNEP) was created, more than a dozen years ago, public understanding of the environmental issues confronting our planet has increased enormously. The Global Environment Monitoring System (GEMS) has provided several environmental assessments including urban air pollution, climate modification,…

  8. Some G Pólya Gems from Complex Analysis

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 19; Issue 4. Some G Polya Gems from Complex Analysis. Shobha Madan. General Article Volume 19 Issue 4 April 2014 pp 323-337 ... Author Affiliations. Shobha Madan1. Department of Mathematics Indian Institute of Technology Kanpur 208 016, India.

  9. Gems: Obiects of Aesthetic Beauty and Scientific Curiosity

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 10; Issue 12. Gems: Obiects of Aesthetic Beauty and Scientific Curiosity. A K Ramdas. Volume 10 Issue 12 December 2005 pp 39-41. Fulltext. Click here to view fulltext PDF. Permanent link: http://www.ias.ac.in/article/fulltext/reso/010/12/0039-0041 ...

  10. Low-Cost PicoAmpere Meter for GEM detectors

    CERN Document Server

    Buhagiar, Karl

    2013-01-01

    Measurement of picoampere current was only possible using very expensive instrumentation. The objective of my project at CERN was to participate in the development and test of a very low-cost picoampere current measuring box for HV lines in GEM detectors.

  11. Hard assets : The return of rare diamonds and gems

    NARCIS (Netherlands)

    Renneboog, Luc; Spaenjers, Christophe; Grynberg, Roman; Mbayi, Letsema

    This note examines the investment performance of diamonds and other gems (sapphires, rubies, and emeralds) over the period 1999–2010, using a novel data set of auction transactions. Over our time frame, the annualized real USD returns for white and colored diamonds equaled 6.4% and 2.9%,

  12. The Gravity and Extreme Magnetism Small Explorer (GEMS)

    Science.gov (United States)

    Kallman, T. R.

    2011-01-01

    The Gravity and Extreme Magnetism Small Explorer (GEMS) was selected by NASA for flight in 2014 to make a sensitive search for X-ray polarization from a wide set of source classes, including stellar black holes, Seyfert galaxies and quasars, blazars, rotation and accretion-powered pulsars, magnetars, shell supernova remnants and pulsar wind nebulae. Among the primary scientific objectives are determining the effects of the spin of black holes and the geometry of supermassive black hole accretion, determining the configurations of the magnetic fields and the X-ray emission of magnetars, and determining the magnetic structure of the supernova shocks in which cosmic rays are accelerated. GEMS will observe 23 targets during a 16 month prime mission, in observations that will be able to reach predicted levels of polarization. The mission can be extended to provide a guest observer phase. The GEMS instrument has time projection chamber polarimeters with high 2-10 keV efficiency at the focus of thin foil mirrors. The 4.5 m focal length mirrors will be deployed on an extended boom. The spacecraft with the instrument is rotated with a period of about 10 minutes to enable measurement and correction of systematic errors. A small Bragg reflection soft X-ray experiment takes advantage of this rotation to obtain a measurement at 0.5 keV. The design of the GEMS instrument and the mission, the expected performance and the planned science program will be discussed.

  13. Hard Assets : The Returns on Rare Diamonds and Gems

    NARCIS (Netherlands)

    Renneboog, L.D.R.; Spaenjers, C.

    2011-01-01

    This paper examines the investment performance of diamonds and other gems (sapphires, rubies, and emeralds) over the period 1999-2010, using a novel data set of auction transactions. Between 1999 and 2010, the annualized real USD returns for white and colored diamonds equaled 6.4% and 2.9%,

  14. Quality of the spare triple-GEM detectors

    CERN Document Server

    Lenci, Rosario; Paoletti, Emiliano; Pasquali, Luigi; Pinci, Davide; Piscitelli, Carmelo; Poli Lener, Marco; Sciubba, Adalberto; Tskhadadze, Edisher

    2017-01-01

    Triple-GEM chambers equip the inner region of the M1 muon station. In order to provide spare detectors in case of problems in the operating ones, new chambers have been assembled at the Frascati National Laboratories of the INFN. This note summarizes the results of the quality tests performed at the end of the production procedure.

  15. Continuous health monitoring of Graphite Epoxy Motorcases (GEM)

    Science.gov (United States)

    Finlayson, Richard D.; Schaafsma, David T.; Shen, H. Warren; Carlos, Mark F.; Miller, Ronnie K.; Shepherd, Brent

    2001-07-01

    Following the explosion of Delta 241 (IIR-1) on January 17th, 1997, the failure investigation board concluded that the Graphite Epoxy Motorcases (GEM's) should be inspected for damage just prior to launch. Subsequent investigations and feedback from industry led to an Aerospace Corporation proposal to instrument the entire fleet of GEM's with a continuous health monitoring system. The period of monitoring would extend from the initial acceptance testing through final erection on the launch pad. As this proposal demonstrates, (along with the increasing use of advanced composite materials in aircraft, automobiles, military hardware, and aerospace components such as rocket motorcases) a sizable need for composite health assessment measures exist. Particularly where continuous monitoring is required for the detection of damage from impacts and other sources of high mechanical and thermal stresses. Even low-momentum impacts can lead to barely visible impact damage (BVID), corresponding to a significant weakening of the composite. This damage, undetectable by visual inspection, can in turn lead to sudden and catastrophic failure when the material is subjected to a normal operating load. There is perhaps no system with as much potential for truly catastrophic failure as a rocket motor. We will present an update on our ongoing efforts with the United States Air Force Delta II Program Office, and The Aerospace Corporation. This will cover the development of a local, portable, surface-mounted, fiberoptic sensor based impact damage monitor designed to operate on a Delta II GEM during transport, storage, and handling. This system is designed to continuously monitor the GEMs, to communicate wirelessly with base stations and maintenance personnel, to operate autonomously for extended periods, and to fit unobtrusively on the GEM itself.

  16. A micro-TCA based data acquisition system for the Triple-GEM detectors for the upgrade of the CMS forward muon spectrometer

    Science.gov (United States)

    Lenzi, T.

    2017-01-01

    The Gas Electron Multiplier (GEM) upgrade project aims at improving the performance of the muon spectrometer of the Compact Muon Solenoid (CMS) experiment which will suffer from the increase in luminosity of the Large Hadron Collider (LHC). The GEM collaboration proposes to instrument the first muon station with Triple-GEM detectors, a technology which has proven to be resistant to high fluxes of particles. The architecture of the readout system is based on the use of the microTCA standard hosting FPGA-based Advanced Mezzanine Card (AMC) and of the Versatile Link with the GBT chipset to link the on-detector electronics to the micro-TCA boards. For the front-end electronics a new ASIC, called VFAT3, is being developed. On the detector, a Xilinx Virtex-6 FPGA mezzanine board, called the OptoHybrid, has to collect the data from 24 VFAT3s and to transmit the data optically to the off-detector micro-TCA electronics, as well as to transmit the trigger data at 40 MHz to the CMS Cathode Strip Chamber (CSC) trigger. The microTCA electronics provides the interfaces from the detector (and front-end electronics) to the CMS DAQ, TTC (Timing, Trigger and Control) and Trigger systems. In this paper, we will describe the DAQ system of the Triple-GEM project and provide results from the latest test beam campaigns done at CERN.

  17. A new Slow Control and Run Initialization Byte-wise Environment (SCRIBE) for the quality control of mass-produced CMS GEM detectors

    CERN Document Server

    Colafranceschi, Stefano

    2016-01-01

    The CMS collaboration aims at improving the muon trigger and tracking performance at the HL-LHC by installing new Gas Electron Multiplier (GEM) detectors in the endcaps of the CMS experiment. Construction and commissioning of GEM detectors for the first muon endcap stations is ramping up in several laboratories using common quality control protocols. The SCRIBE framework is a scalable and cross-platform web-based application for the RD51 Scalable Readout System (SRS) that controls data acquisition and analyzes data in near real time. It has been developed mainly to simplify and standardize measurements of the GEM detector response uniformities with x-rays across all production sites. SCRIBE works with zero suppression of raw SRS pulse height data. This has increased acquisition rates to 5 kHz for a CMS GEM detector with 3072 strips and allows strip-by-strip response comparisons with a few hours of data taking. SCRIBE also manages parallel data reconstruction to provide near real-time feedback on the detector ...

  18. Fiber Bragg Grating sensors for deformation monitoring of GEM foils in HEP detectors

    CERN Document Server

    AUTHOR|(CDS)2071648; Bianco, S; Caponero, M; Muhammad, S; Passamonti, L; Piccolo, D; Pierluigi, D; Raffone, G; Russo, A; Saviano, G

    2015-01-01

    Fiber Bragg Grating (FBG) sensors have been so far mainly used in high energy physics (HEP) as high precision positioning and re-positioning sensors and as low cost, easy to mount, radiation hard and low space- consuming temperature and humidity devices. FBGs are also commonly used for very precise strain measurements. In this work we present a novel use of FBGs as flatness and mechanical tensioning sensors applied to the wide Gas Electron Multiplier (GEM) foils of the GE1/1 chambers of the Compact Muon Solenoid (CMS) experiment at Large Hadron Collider (LHC) of CERN. A network of FBG sensors has been used to determine the optimal mechanical tension applied and to characterize the mechanical stress applied to the foils. The preliminary results of the test performed on a full size GE1/1 final prototype and possible future developments will be discussed.

  19. Triple-GEM detectors for the innermost region of the muon apparatus at the LHCb experiment

    CERN Document Server

    Poli-Lener, M; Bencivenni, G

    2005-01-01

    The LHCb experiment will take place at the future LHC accelerator at CERN and will start in 2007. It is a single arm spectrometer to precision measurements of CP violation and rare decays in the b quark sector. Recent experimental results have shown that CP violation is large in this sector. LHCb is designed with a robust and flexible trigger in order to extensively gain access to a wide spread of different physical processes involving the beauty particles. This will allow to over-constrain the Standard Model predictions about $\\mathcal{CP}$ violation, and to discover any possible inconsistency, which would reveal the presence of ''New Physics''. The work presented in this thesis has two main parts: the development of a charged particle detector based on Gas Electron Multiplication (GEM) and the study of luminosity measurements with the physical channels $Z^{0} \\rightarrow \\mu^{+} \\mu^{-}$ and $W^{\\pm} \\rightarrow \\mu^{\\pm} \

  20. Tomographic capabilities of the new GEM based SXR diagnostic of WEST

    Science.gov (United States)

    Jardin, A.; Mazon, D.; O'Mullane, M.; Mlynar, J.; Loffelmann, V.; Imrisek, M.; Chernyshova, M.; Czarski, T.; Kasprowicz, G.; Wojenski, A.; Bourdelle, C.; Malard, P.

    2016-07-01

    The tokamak WEST (Tungsten Environment in Steady-State Tokamak) will start operating by the end of 2016 as a test bed for the ITER divertor components in long pulse operation. In this context, radiative cooling of heavy impurities like tungsten (W) in the Soft X-ray (SXR) range [0.1 keV; 20 keV] is a critical issue for the plasma core performances. Thus reliable tools are required to monitor the local impurity density and avoid W accumulation. The WEST SXR diagnostic will be equipped with two new GEM (Gas Electron Multiplier) based poloidal cameras allowing to perform 2D tomographic reconstructions in tunable energy bands. In this paper tomographic capabilities of the Minimum Fisher Information (MFI) algorithm developed for Tore Supra and upgraded for WEST are investigated, in particular through a set of emissivity phantoms and the standard WEST scenario including reconstruction errors, influence of noise as well as computational time.

  1. Development of the GEM-TPC X-ray Polarimeter with the Scalable Readout System

    Directory of Open Access Journals (Sweden)

    Kitaguchi Takao

    2018-01-01

    Full Text Available We have developed a gaseous Time Projection Chamber (TPC containing a single-layered foil of a gas electron multiplier (GEM to open up a new window on cosmic X-ray polarimetry in the 2–10 keV band. The micro-pattern TPC polarimeter in combination with the Scalable Readout System produced by the RD51 collaboration has been built as an engineering model to optimize detector parameters and improve polarimeter sensitivity. The polarimeter was characterized with unpolarized X-rays from an X-ray generator in a laboratory and polarized X-rays on the BL32B2 beamline at the SPring-8 synchrotron radiation facility. Preliminary results show that the polarimeter has a comparable modulation factor to a prototype of the flight one.

  2. A dynamic method for charging-up calculations: the case of GEM

    CERN Document Server

    Correia, P M M; Azevedo, C D R; Silva, A L M; Veenhof, R; Nemallapudi, Mythra Varun; Veloso, J F C A

    2014-01-01

    The simulation of Micro Pattern Gaseous Detectors (MPGDs) signal response is an important and powerful tool for the design and optimization of such detectors. However, several attempts to simulate exactly the effective charge gain have not been completely successful. Namely, the gain stability over time has not been fully understood. Charging-up of the insulator surfaces have been pointed as one of the responsible for the difference between experimental and Monte Carlo results. This work describes two iterative methods to simulate the charging-up in one MPGD device, the Gas Electron Multiplier (GEM). The first method uses a constant step for avalanches time evolution, very detailed, but slower to compute. The second method uses a dynamic step that improves the computing time. Good agreement between both methods was reached. Despite of comparison with experimental results shows that charging-up plays an important role in detectors operation, should not be the only responsible for the difference between simulat...

  3. Gain characteristics of a 100 μm thick GEM in Krypton-CO2 mixtures

    Science.gov (United States)

    Roque, R. C.; Natal da Luz, H.; Carramate, L. F. N. D.; Azevedo, C. D. R.; Mir, J. A.; Amaro, F. D.

    2017-12-01

    The operation of a Micropattern Gaseous Detector (MPGD) comprising a cascade of two non-standard Gas Electron Multipliers (GEM) made from a 100 μm kapton foil was evaluated in pure krypton and in krypton-CO2 mixtures. The final avalanche charge was collected in a 2D strip readout, providing an active area of 10×10 cm2 for the entire detection system. For each mixture, the effective gain and energy resolution were measured as a function of the electric field in the drift, transfer and induction regions. Using X-rays from a 55Fe radioactive source (5.9 keV), gains close to 104 and energy resolution of 22% (FWHM) were achieved in pure krypton under stable conditions, showing the potential of the experimental setup for the following imaging studies.

  4. Resolution studies of cosmic-ray tracks in a TPC with GEM readout

    International Nuclear Information System (INIS)

    Carnegie, R.K.; Dixit, M.S.; Dubeau, J.; Karlen, D.; Martin, J.-P.; Mes, H.; Sachs, K.

    2005-01-01

    A large volume time projection chamber (TPC) is a leading candidate for the central tracking detector at a future high energy linear collider. To improve the resolution a new readout based on micro-pattern gas detectors is being developed. Measurements of the spatial resolution of cosmic-ray tracks in a GEM TPC are presented. We find that the resolution suffers if the readout pads are too wide with respect to the charge distribution at the readout plane due to insufficient charge sharing. For narrow pads of 2x6mm2 we measure a resolution of 100μm at short drift distances in the absence of an axial magnetic field. The dependence of the spatial resolution as a function of drift distance allows the determination of the underlying electron statistics. Our results show that the present technique uses about half the statistical power available from the number of primary electrons. The track angle effect is observed as expected

  5. Hardness amplification in nondeterministic logspace

    OpenAIRE

    Gupta, Sushmita

    2007-01-01

    A hard problem is one which cannot be easily computed by efficient algorithms. Hardness amplification is a procedure which takes as input a problem of mild hardness and returns a problem of higher hardness. This is closely related to the task of decoding certain error-correcting codes. We show amplification from mild average case hardness to higher average case hardness for nondeterministic logspace and worst-to-average amplification for nondeterministic linspace. Finally we explore possible ...

  6. Evidence of high-elevation amplification versus Arctic amplification.

    Science.gov (United States)

    Wang, Qixiang; Fan, Xiaohui; Wang, Mengben

    2016-01-12

    Elevation-dependent warming in high-elevation regions and Arctic amplification are of tremendous interest to many scientists who are engaged in studies in climate change. Here, using annual mean temperatures from 2781 global stations for the 1961-2010 period, we find that the warming for the world's high-elevation stations (>500 m above sea level) is clearly stronger than their low-elevation counterparts; and the high-elevation amplification consists of not only an altitudinal amplification but also a latitudinal amplification. The warming for the high-elevation stations is linearly proportional to the temperature lapse rates along altitudinal and latitudinal gradients, as a result of the functional shape of Stefan-Boltzmann law in both vertical and latitudinal directions. In contrast, neither altitudinal amplification nor latitudinal amplification is found within the Arctic region despite its greater warming than lower latitudes. Further analysis shows that the Arctic amplification is an integrated part of the latitudinal amplification trend for the low-elevation stations (≤500 m above sea level) across the entire low- to high-latitude Northern Hemisphere, also a result of the mathematical shape of Stefan-Boltzmann law but only in latitudinal direction.

  7. Evidence of high-elevation amplification versus Arctic amplification

    Science.gov (United States)

    Wang, Qixiang; Fan, Xiaohui; Wang, Mengben

    2016-01-01

    Elevation-dependent warming in high-elevation regions and Arctic amplification are of tremendous interest to many scientists who are engaged in studies in climate change. Here, using annual mean temperatures from 2781 global stations for the 1961-2010 period, we find that the warming for the world’s high-elevation stations (>500 m above sea level) is clearly stronger than their low-elevation counterparts; and the high-elevation amplification consists of not only an altitudinal amplification but also a latitudinal amplification. The warming for the high-elevation stations is linearly proportional to the temperature lapse rates along altitudinal and latitudinal gradients, as a result of the functional shape of Stefan-Boltzmann law in both vertical and latitudinal directions. In contrast, neither altitudinal amplification nor latitudinal amplification is found within the Arctic region despite its greater warming than lower latitudes. Further analysis shows that the Arctic amplification is an integrated part of the latitudinal amplification trend for the low-elevation stations (≤500 m above sea level) across the entire low- to high-latitude Northern Hemisphere, also a result of the mathematical shape of Stefan-Boltzmann law but only in latitudinal direction.

  8. GEM1: First-year modeling and IT activities for the Global Earthquake Model

    Science.gov (United States)

    Anderson, G.; Giardini, D.; Wiemer, S.

    2009-04-01

    GEM is a public-private partnership initiated by the Organisation for Economic Cooperation and Development (OECD) to build an independent standard for modeling and communicating earthquake risk worldwide. GEM is aimed at providing authoritative, open information about seismic risk and decision tools to support mitigation. GEM will also raise risk awareness and help post-disaster economic development, with the ultimate goal of reducing the toll of future earthquakes. GEM will provide a unified set of seismic hazard, risk, and loss modeling tools based on a common global IT infrastructure and consensus standards. These tools, systems, and standards will be developed in partnership with organizations around the world, with coordination by the GEM Secretariat and its Secretary General. GEM partners will develop a variety of global components, including a unified earthquake catalog, fault database, and ground motion prediction equations. To ensure broad representation and community acceptance, GEM will include local knowledge in all modeling activities, incorporate existing detailed models where possible, and independently test all resulting tools and models. When completed in five years, GEM will have a versatile, penly accessible modeling environment that can be updated as necessary, and will provide the global standard for seismic hazard, risk, and loss models to government ministers, scientists and engineers, financial institutions, and the public worldwide. GEM is now underway with key support provided by private sponsors (Munich Reinsurance Company, Zurich Financial Services, AIR Worldwide Corporation, and Willis Group Holdings); countries including Belgium, Germany, Italy, Singapore, Switzerland, and Turkey; and groups such as the European Commission. The GEM Secretariat has been selected by the OECD and will be hosted at the Eucentre at the University of Pavia in Italy; the Secretariat is now formalizing the creation of the GEM Foundation. Some of GEM's global

  9. GEMS: Underwater spectrometer for long-term radioactivity measurements

    Energy Technology Data Exchange (ETDEWEB)

    Sartini, Ludovica, E-mail: ludovica.sartini@ingv.i [Istituto Nazionale di Geofisica e Vulcanologia (INGV), Sect.Roma 2, Roma (Italy); Genoa University, Genoa (Italy); Simeone, Francesco; Pani, Priscilla [' Sapienza' University and Istituto Nazionale di Fisica Nucleare (INFN), Sect.Roma, Roma (Italy); Lo Bue, Nadia; Marinaro, Giuditta [Istituto Nazionale di Geofisica e Vulcanologia (INGV), Sect.Roma 2, Roma (Italy); Grubich, Andry; Lobko, Alexander [Institute for Nuclear Problems (INP), Belarus State University, Minsk (Belarus); Etiope, Giuseppe [Istituto Nazionale di Geofisica e Vulcanologia (INGV), Sect.Roma 2, Roma (Italy); Capone, Antonio [' Sapienza' University and Istituto Nazionale di Fisica Nucleare (INFN), Sect.Roma, Roma (Italy); Favali, Paolo [Istituto Nazionale di Geofisica e Vulcanologia (INGV), Sect.Roma 2, Roma (Italy); Gasparoni, Francesco; Bruni, Federico [Tecnomare S.p.A., Venice (Italy)

    2011-01-21

    GEMS (Gamma Energy Marine Spectrometer) is a prototype of an autonomous radioactivity sensor for underwater measurements, developed in the framework for a development of a submarine telescope for neutrino detection (KM3NeT Design Study Project). The spectrometer is highly sensitive to gamma rays produced by {sup 40}K decays but it can detect other natural (e.g., {sup 238}U,{sup 232}Th) and anthropogenic radio-nuclides (e.g., {sup 137}Cs). GEMS was firstly tested and calibrated in the laboratory using known sources and it was successfully deployed for a long-term (6 months) monitoring at a depth of 3200 m in the Ionian Sea (Capo Passero, offshore Eastern Sicily). The instrument recorded data for the whole deployment period within the expected specifications. This monitoring provided, for the first time, a continuous time-series of radioactivity in deep-sea.

  10. Sensory and Flavor Characteristics of Tomato Juice from Garden Gem and Roma Tomatoes with Comparison to Commercial Tomato Juice.

    Science.gov (United States)

    Zhu, Yaozhou; Sims, Charles A; Klee, Harry J; Sarnoski, Paul J

    2018-01-01

    The objective of this study was to characterize the flavor of a premium Florida tomato variety that has significant potential for producing a high quality processed juice product. A high-quality Florida plum tomato variety (Garden Gem), and a typical grocery-store plum tomato variety (Roma) were thermally processed into tomato juices without any additives. The 2 pilot products and a popular commercially available tomato juice (low sodium with sugar and flavor added) were compared using sensory evaluation and instrumental analysis. Flavor compounds in these products were identified using dynamic headspace purge and trap-gas chromatography-mass spectrometry (PT-GC-MS) by MS library match and retention index and were semi-quantitated using internal standards. Color, uniformity, overall liking, tomato flavor, sweetness and texture were rated using a hedonic scale. Analysis of variance, correlation and principal component analysis were used to analyze both sensory and flavor data. Among the 3 products, Garden Gem juice was rated significantly (P sweetness by the 119 consumer panelists in both seasons. Garden Gem juice was found to contain higher levels of 3 sweet/fruity related aroma compounds: 6-methyl-5-hepten-2-one, linalool, and β-ionone. The commercial tomato juice contained a high level of the Maillard reaction-related notes furfural, dimethyl sulfide, and the least amount of green-related notes (hexanal, E-2-hexenal and Z-2-heptenal). The flavor profile of the Roma tomato juice was similar to Garden Gem juice except it contained substantially lower amounts of hexanal and 2-isobutylthiazole. The compound β-ionone (fruity note) was not detected in either the commercial or Roma juice. This proof of concept study demonstrates that high flavor quality tomatoes can be used to create better tasting processed tomato products. The study also demonstrates how sensory preference can confer a potential market advantage over existing commercial products. The Garden Gem

  11. Serial data acquisition for GEM-2D detector

    International Nuclear Information System (INIS)

    Kolasinski, Piotr; Pozniak, Krzysztof T.; Czarski, Tomasz; Linczuk, Maciej; Byszuk, Adrian; Chernyshova, Maryna; Juszczyk, Bartlomiej; Kasprowicz, Grzegorz; Wojenski, Andrzej; Zabolotny, Wojciech; Zienkiewicz, Pawel; Mazon, Didier; Malard, Philippe; Herrmann, Albrecht; Vezinet, Didier

    2014-01-01

    This article debates about data fast acquisition and histogramming method for the X-ray GEM detector. The whole process of histogramming is performed by FPGA chips (Spartan-6 series from Xilinx). The results of the histogramming process are stored in an internal FPGA memory and then sent to PC. In PC data is merged and processed by MATLAB. The structure of firmware functionality implemented in the FPGAs is described. Examples of test measurements and results are presented. (authors)

  12. Serial data acquisition for GEM-2D detector

    Science.gov (United States)

    Kolasinski, Piotr; Pozniak, Krzysztof T.; Czarski, Tomasz; Linczuk, Maciej; Byszuk, Adrian; Chernyshova, Maryna; Juszczyk, Bartlomiej; Kasprowicz, Grzegorz; Wojenski, Andrzej; Zabolotny, Wojciech; Zienkiewicz, Pawel; Mazon, Didier; Malard, Philippe; Herrmann, Albrecht; Vezinet, Didier

    2014-11-01

    This article debates about data fast acquisition and histogramming method for the X-ray GEM detector. The whole process of histogramming is performed by FPGA chips (Spartan-6 series from Xilinx). The results of the histogramming process are stored in an internal FPGA memory and then sent to PC. In PC data is merged and processed by MATLAB. The structure of firmware functionality implemented in the FPGAs is described. Examples of test measurements and results are presented.

  13. Modelling Chemical Equilibrium Partitioning with the GEMS-PSI Code

    Energy Technology Data Exchange (ETDEWEB)

    Kulik, D.; Berner, U.; Curti, E

    2004-03-01

    Sorption, co-precipitation and re-crystallisation are important retention processes for dissolved contaminants (radionuclides) migrating through the sub-surface. The retention of elements is usually measured by empirical partition coefficients (Kd), which vary in response to many factors: temperature, solid/liquid ratio, total contaminant loading, water composition, host-mineral composition, etc. The Kd values can be predicted for in-situ conditions from thermodynamic modelling of solid solution, aqueous solution or sorption equilibria, provided that stoichiometry, thermodynamic stability and mixing properties of the pure components are known (Example 1). Unknown thermodynamic properties can be retrieved from experimental Kd values using inverse modelling techniques (Example 2). An efficient, advanced tool for performing both tasks is the Gibbs Energy Minimization (GEM) approach, implemented in the user-friendly GEM-Selector (GEMS) program package, which includes the Nagra-PSI chemical thermodynamic database. The package is being further developed at PSI and used extensively in studies relating to nuclear waste disposal. (author)

  14. Development of near infrared spectrometer for gem materials study

    Science.gov (United States)

    Jindata, W.; Meesiri, W.; Wongkokua, W.

    2015-07-01

    Most of gem materials can be characterized by infrared absorption spectroscopy. Normally, mid infrared absorption technique has been applied for investigating fundamental vibrational modes. However, for some gem materials, such as tourmaline, NIR is a better choice due to differentiation. Most commercial NIR spectrometers employ complicated dispersive grating or Fourier transform techniques. In this work, we developed a filter type NIR spectrometer with the availability of high efficiency and low-cost narrow bandpass NIR interference filters to be taught in a physics laboratory. The instrument was designed for transmission-mode configuration. A 50W halogen lamp was used as NIR source. There were fourteen NIR filters mounted on a rotatory wheel for wavelength selection ranging from 1000-1650 nm with steps of 50 nm. A 1.0 mm diameter of InGaAs photodiode was used as the detector for the spectrometer. Hence, transparent gem materials can be used as samples for experiment. Student can learn vibrational absorption spectroscopy as well as Beer-Lambert law from the development of this instrument.

  15. Modelling Chemical Equilibrium Partitioning with the GEMS-PSI Code

    International Nuclear Information System (INIS)

    Kulik, D.; Berner, U.; Curti, E.

    2004-01-01

    Sorption, co-precipitation and re-crystallisation are important retention processes for dissolved contaminants (radionuclides) migrating through the sub-surface. The retention of elements is usually measured by empirical partition coefficients (Kd), which vary in response to many factors: temperature, solid/liquid ratio, total contaminant loading, water composition, host-mineral composition, etc. The Kd values can be predicted for in-situ conditions from thermodynamic modelling of solid solution, aqueous solution or sorption equilibria, provided that stoichiometry, thermodynamic stability and mixing properties of the pure components are known (Example 1). Unknown thermodynamic properties can be retrieved from experimental Kd values using inverse modelling techniques (Example 2). An efficient, advanced tool for performing both tasks is the Gibbs Energy Minimization (GEM) approach, implemented in the user-friendly GEM-Selector (GEMS) program package, which includes the Nagra-PSI chemical thermodynamic database. The package is being further developed at PSI and used extensively in studies relating to nuclear waste disposal. (author)

  16. Efficient audio power amplification - challenges

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, Michael A.E.

    2005-07-01

    For more than a decade efficient audio power amplification has evolved and today switch-mode audio power amplification in various forms are the state-of-the-art. The technical steps that lead to this evolution are described and in addition many of the challenges still to be faced and where extensive research and development are needed is covered. (au)

  17. Efficient Audio Power Amplification - Challenges

    DEFF Research Database (Denmark)

    Andersen, Michael Andreas E.

    2005-01-01

    For more than a decade efficient audio power amplification has evolved and today switch-mode audio power amplification in various forms are the state-of-the-art. The technical steps that lead to this evolution are described and in addition many of the challenges still to be faced and where...... extensive research and development are needed is covered....

  18. Robustness test of a system of MSGC+GEM detectors at the cyclotron facility of the Paul Scherrer institute

    Energy Technology Data Exchange (ETDEWEB)

    Ageron, M.; Albert, A.; Barvich, T.; Beaumont, W.; Beckers, T.; Bernier, K.; Bluem, P.; Bouhali, O.; Boulogne, I.; Bouvet, D.; Brom, J.M.; Charles, F.; Coffin, J.; Contardo, D.; Daubie, E.; Didierjean, F.; Erdmann, M.; De Lentdecker, G.; Devroede, O.; De Troy, J.; Ernenwein, J.P.; Fahrer, M.; Fluegge, G.; Fontaine, J.C.; Geist, W.; Goerlach, U.; Gottschalk, M.; Helleboid, J.M.; Huss, D.; Iacopi, F.; Kaercher, K.; Kuehn, F.; Juillot, P. E-mail: juillot@in2p3.fr; Lounis, A.; Maazouzi, C.; Macke, D.; Martin, C.; Mirabito, L.; Moreau, S.; Mueller, T.; Neuberger, D.; Nowack, A.; Perries, S.; Ripp-Baudot, I.; Roederer, F.; Schulte, R.; Shekhtman, L.; Simonis, H.J.; Struczinski, W.; Tatarinov, A.; Thuemmel, W.H.; Udo, F.; Doninck, W. van; Dyck, C. van; Vander Velde, C.; Vanlaer, P.; Lancker, L. van; Weiler, T.; Zander, A.; Zghiche, A.; Zhukov, V

    2001-10-01

    A system of detector modules consisting of a large size Gas Electron Multiplier (GEM), coupled to Micro Strip Gas Counters (MSGC), has been exposed to a pion beam at the Paul Scherrer Institute Cyclotron facility. As part of a CMS tracker milestone, the aim of this test was to investigate the robustness of such detectors when exposed to experimental conditions close to what is expected at the Large Hadron Collider (LHC) of CERN. Eighteen detector modules have been operated at voltage settings corresponding to 98% detection efficiency for Minimum Ionizing Particles during a period of 5 weeks. Sparking rates and strip losses have been monitored throughout the exposure. An operation margin of at least a factor of three with respect to the required gas gain has been demonstrated.

  19. Statistical exploration of gaseous elemental mercury (GEM) measured at Cape Point from 2007 to 2011

    Science.gov (United States)

    Venter, A. D.; Beukes, J. P.; van Zyl, P. G.; Brunke, E.-G.; Labuschagne, C.; Slemr, F.; Ebinghaus, R.; Kock, H.

    2015-09-01

    The authors evaluated continuous high-resolution gaseous elemental mercury (GEM) data from the Cape Point Global Atmosphere Watch (CPT GAW) station with different statistical analysis techniques. GEM data were evaluated by cluster analysis and the results indicated that two clusters, separated at 0.904 ng m-3, existed. The air mass history for the two-cluster solution was investigated by means of back-trajectory analysis. The air mass back-trajectory net result showed lower GEM concentrations originating from the sparsely populated semi-arid interior of South Africa and the marine environment, whereas higher GEM concentrations originated predominately along the coast of South Africa that most likely coincide with trade routes and industrial activities in urban areas along the coast. Considering the net result from the air mass back-trajectories, it is evident that not all low GEM concentrations are from marine origin, and similarly, not all high GEM concentrations have a terrestrial origin. Equations were developed by means of multi-linear regression (MLR) analysis that allowed for the estimation and/or prediction of atmospheric GEM concentrations from other atmospheric parameters measured at the CPT GAW station. These equations also provided some insight into the relation and interaction of GEM with other atmospheric parameters. Both measured and MLR calculated data confirm a decline in GEM concentrations at CPT GAW over the period evaluated.

  20. Study and optimization of the light-yield of a triple-GEM detector

    CERN Document Server

    Campagnola, Roberto; Mazzitelli, Giovanni

    The high-resolution tracking of low energy release particles had a remarkable development in recent years and will give a crucial contribution in different fields, from medical uses to those in dark matter search. Characteristics, such as high space and time resolution, low material budget, large volumes, low costs, make gas detectors ideal candidates for this type of devices. A very promising technique involves the optical reading of the light produced by the de-excitation of gas molecules during the processes of electron multiplication. This type of detector has been made possible thanks to the great progresses achieved in last years in the performance in micro pattern gas detector and in the evolution of the CMOS technology which led to the production of sensors able of offering high sensitivity and granularity combined with a very low noise level. In this thesis the performance of a prototype where the light is produced through the multiplication of electrons in a triple GEM structure and acquired by a c...

  1. ARTROC—a readout ASIC for GEM-based full-field XRF imaging system

    Science.gov (United States)

    Fiutowski, T.; Koperny, S.; Łach, B.; Mindur, B.; Świentek, K.; Wiącek, P.; Dąbrowski, W.

    2017-12-01

    In the paper we report on development of an Application Specific Integrated Circuit (ASIC), called ARTROC, being part of a full-field X-ray fluorescence spectroscopy (XRF) imaging system equipped with a standard three stage Gas Electron Multiplier (GEM) detector of 10×10 cm2 area. The ARTROC consists of 64 independent channels, allowing for simultaneous recording of the amplitudes (energy sub-channel) and time stamps (timing sub-channel) of incoming signals. Thanks to the implemented token-based read out of derandomizing buffers, the ASIC also provides data sparsification and full zero suppression. Reconstruction of the hit positions is performed in an external data acquisition system by matching the time stamps of signals recorded in X- and Y-strips. The amplitude information is used for centre of gravity finding in clusters of signals on neighbouring strips belonging to the same detection events. The ASIC could work in one of six gain modes and one of two speed modes. In a slower mode the maximum count rate per channel is 105/s while in a faster mode it is three times higher. The ARTROC comprises also input protection circuits against possible random discharges inside active detector volume, so it can be used without any additional input components. The ASIC has been designed in 350 nm CMOS process. The basic functionality and parameters have been evaluated using the testability functions implemented in the ASIC design. The ASIC has been also tested in a fully equipped GEM detector set-up with X-rays source.

  2. A GEM-TPC prototype with low-Noise highly integrated front-end electronics for linear collider studies

    CERN Document Server

    Kappler, Steffen; Kaminski, Jochen; Ledermann, Bernhard; Müller, Thomas; Ronan, Michael T; Ropelewski, Leszek; Sauli, Fabio; Settles, Ronald

    2004-01-01

    Connected to the linear collider project, studies on the readout of time projection chambers (TPCs) based on the gas electron multiplier (GEM) are ongoing. Higher granularity and intrinsically suppressed ion feedback are the major advantages of this technology. After a short discussion of these issues, we present the design of a small and very flexible TPC prototype, whose cylindrical drift volume can be equipped with endcaps of different gas detector types. An endcap with multi-GEM readout is currently set up and successfully operated with a low-noise highly integrated front-end electronics. We discuss results of measurements with this system in high intensity particle beams at CERN, where 99.3 plus or minus 0.2% single-pad-row efficiency could be achieved at an effective gain of 2.5 multiplied by 10**3 only, and spatial resolutions down to 63 plus or minus 3 mum could be demonstrated. Finally, these results are extrapolated to the high magnetic field in a linear collider TPC. 5 Refs.

  3. DNAzyme Feedback Amplification: Relaying Molecular Recognition to Exponential DNA Amplification.

    Science.gov (United States)

    Liu, Meng; Yin, Qingxin; McConnell, Erin M; Chang, Yangyang; Brennan, John D; Li, Yingfu

    2018-03-26

    Technologies capable of linking DNA amplification to molecular recognition are very desirable for ultrasensitive biosensing applications. We have developed a simple but powerful isothermal DNA amplification method, termed DNAzyme feedback amplification (DFA), that is capable of relaying molecular recognition to exponential DNA amplification. The method incorporates both an RNA-cleaving DNAzyme (RCD) and rolling circle amplification (RCA) carried out by a special DNA polymerase using a circular DNA template. DFA begins with a stimulus-dependent RCA reaction, producing tandemly linked RCDs in long-chain DNA products. These RCDs cleave an RNA-containing DNA sequence to form additional primers that hybridize to the circular DNA molecule, giving rise to DNA assemblies that act as the new inputs for RCA. The RCA reaction and the cleavage event keep on feeding each other autonomously, resulting in exponential growth of repetitive DNA sequences that can be easily detected. This method can be used for the detection of both nucleic acid based targets and non-nucleic acid analytes. In this article, we discuss the conceptual framework of the feedback amplification approach, the essential features of this method as well as remaining challenges and possible solutions. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Operation of the triple-GEM detectors in the tagging system of the KEDR experiment on the VEPP-4M collider

    Energy Technology Data Exchange (ETDEWEB)

    Aulchenko, V M; Beloborodova, O L; Bobrov, A V; Bondar, A E; Kudryavtsev, V N; Shamov, A G; Shekhtman, L I; Zhilich, V N; Zhulanov, V V, E-mail: L.I.Shekhtman@inp.nsk.su [Budker Institute of Nuclear Physics, 11 Lavrentiev Avenue, Novosibirsk 630090 (Russian Federation)

    2011-07-15

    The tagging system (TS) of the KEDR detector is designed for study of two-photon interactions on the VEPP-4M electron-positron collider. The upgrade of the TS was completed and 8 triple-GEM detectors were added to the system with a single detector sensitive area up to 250*100 mm{sup 2}, a spatial resolution in the beam orbit plane close to 70 {mu}m and a small angle stereo readout providing a resolution of around 200 {mu}m in perpendicular direction. The triple-GEM detectors were included into the KEDR DAQ system, and since the beginning of the 2010-2011 season they have demonstrated stable operation at a gas gain of 20000-40000 and efficiency of 95-97%. The new detectors will allow performing background suppression and improving the energy resolution of the system.

  5. Next generation Chirped Pulse Amplification

    Energy Technology Data Exchange (ETDEWEB)

    Nees, J.; Biswal, S.; Mourou, G. [Univ. Michigan, Center for Ultrafast Optical Science, Ann Arbor, MI (United States); Nishimura, Akihiko; Takuma, Hiroshi

    1998-03-01

    The limiting factors of Chirped Pulse Amplification (CPA) are discussed and experimental results of CPA in Yb:glass regenerative amplifier are given. Scaling of Yb:glass to the petawatt level is briefly discussed. (author)

  6. GEMS Project: A Platform to Investigate Multiple Sclerosis Risk

    Science.gov (United States)

    Xia, Zongqi; White, Charles C.; Owen, Emily K.; Von Korff, Alina; Clarkson, Sarah R.; McCabe, Cristin A.; Cimpean, Maria; Winn, Phoebe A.; Hoesing, Ashley; Steele, Sonya U.; Cortese, Irene C. M.; Chitnis, Tanuja; Weiner, Howard L.; Reich, Daniel S.; Chibnik, Lori B.; De Jager, Philip L.

    2015-01-01

    The Genes and Environment in Multiple Sclerosis (GEMS) project establishes a platform to investigate the events leading to MS in at-risk individuals. It has recruited 2,632 first-degree relatives from across the USA. Using an integrated genetic and environmental risk score, we identified subjects with twice the MS risk when compared to the average family member, and we report an initial incidence rate in these subjects that is 30 times greater than that of sporadic MS. We discuss the feasibility of large-scale studies of asymptomatic at-risk subjects that leverage modern tools of subject recruitment to execute collaborative projects. PMID:26583565

  7. Study on Physical Properties and Chemical Composition of Some Myanmar Gems

    International Nuclear Information System (INIS)

    Kyaw Myint Htoo; Tun Khin; Sein Htoon

    2004-05-01

    Physical properties of some Myanmar gems were studied by using refractometer, dichroscope, polariscope, SG test, UV test and microscope. Then, chemical composition were investigated by XRF-technique. After that, gem identification, evaluation, colour improvement were studied according to these physical properties and chemical composition

  8. Overview of the Gems Model of Volunteer Administration (Generate, Educate, Mobilize and Sustain)

    Science.gov (United States)

    Culp, Ken, III

    2012-01-01

    To organize and coordinate the efforts of many volunteers, a framework for volunteer engagement is needed. The "GEMS" Model of volunteer administration was developed to assist Extension professionals and volunteer coordinators to effectively administer volunteer programs without delivering the program themselves. The GEMS Model is…

  9. Use of aluminium plates to simulate the dosimetry of gems during e-beam irradiation

    International Nuclear Information System (INIS)

    Fortes, Marcio Z.; Sousa, Fernando N.C. de; Boente, Otavio C.; Sousa, Nuno R.A.

    2009-01-01

    The e-beam technology is used in the industrial irradiation of several products like turf, sterilization of medical products, cosmetics, polymers, food, and gems. More than 70% of the gems commercialized in the world receive treatments similar to those present in nature, including heat, and irradiation, in order to improve their value. Since aluminum has a density similar to that of several commercial gems, this paper presents a study of the penetration of electrons in calibrated aluminum plates simulating several different thicknesses ranging from 5 to 30 mm, and comparing with the one obtained in gems. This allows the monitoring of the dose received by gems during irradiation with e-beam systems measuring the delivered surface dose. This procedure is very important for industrial processing of stones due to the irregularities present on most gems, what makes dosimetry a very complex task. The determination of the thicknesses of the gems for which the surface dose is the lowest dose on the whole product assures the precise determination of the minimum dose received by the gems during industrial processing. (author)

  10. A dynamic method for charging-up calculations: the case of GEM

    International Nuclear Information System (INIS)

    Correia, P M M; Oliveira, C A B; Azevedo, C D R; Silva, A L M; Veloso, J F C A; Veenhof, R; Nemallapudi, M Varun

    2014-01-01

    The simulation of Micro Pattern Gaseous Detectors (MPGDs) signal response is an important and powerful tool for the design and optimization of such detectors. However, several attempts to exactly simulate the effective gas gain have not been completely successful. Namely, the gain stability over time has not been fully understood. Charging-up of the insulator surfaces have been pointed as one of the responsible for the difference between experimental and Monte Carlo results. This work describes two iterative methods to simulate the charging-up in one MPGD device, the Gas Electron Multiplier (GEM). The first method, which uses a constant step size for avalanches time evolution, is very detailed but slow to compute. The second method instead uses a dynamic step-size that improves the computing time. Good agreement between both methods was achieved. Comparison with experimental results shows that charging-up plays an important role in detectors operation, explaining the time evolution of the gain. However it doesn't seem to be the only responsible for the difference between measurements and Monte Carlo simulations

  11. Characterization of GEM foils and materials simulation, measurements and interferometric monitoring tools

    CERN Document Server

    Benussi, Luigi

    2015-01-01

    The GE1/1 CMS project consists of 144 GEM chambers of about 0.5 qm active area each, based on the triple GEMs technology, to be installed in the very forward region of the CMS endcap during the long shutdown of LHC in 2108-2019. GE1/1 chambers will be operated for decades in harsh environment, and are expected to perform consistently providing good space and time resolution and excellent rate capabilities. An extensive material science simulation and measurement campaign is in progress to characterize GEM materials, with main focus on the GEM foils. Results are presented on full Finite Element Analysis simulations, measurement of tensile properties and humidity absorption coefficients, both for unused and irradiated samples. Preliminary results are shown on interferometric methods based on Moirè fringes for the monitoring of GEM foils mechanical properties during chamber construction.

  12. Possible Gems and Ultra-Fine Grained Polyphase Units in Comet Wild 2.

    Science.gov (United States)

    Gainsforth, Z.; Butterworth, A. L.; Jilly-Rehak, C. E.; Westphal, A. J.; Brownlee, D. E.; Joswiak, D.; Ogliore, R. C.; Zolensky, M. E.; Bechtel, H. A.; Ebel, D. S.; hide

    2016-01-01

    GEMS and ultrafine grained polyphase units (UFG-PU) in anhydrous IDPs are probably some of the most primitive materials in the solar system. UFG-PUs contain nanocrystalline silicates, oxides, metals and sulfides. GEMS are rounded approximately 100 nm across amorphous silicates containing embedded iron-nickel metal grains and sulfides. GEMS are one of the most abundant constituents in some anhydrous CPIDPs, often accounting for half the material or more. When NASA's Stardust mission returned with samples from comet Wild 2 in 2006, it was thought that UFG-PUs and GEMS would be among the most abundant materials found. However, possibly because of heating during the capture process in aerogel, neither GEMS nor UFG-PUs have been clearly found.

  13. PREFACE: Science's gem: diamond science 2009 Science's gem: diamond science 2009

    Science.gov (United States)

    Mainwood, Alison; Newton, Mark E.; Stoneham, Marshall

    2009-09-01

    Natural diamond has been valued for its appearance and mechanical properties for at least two thousand years. As a gem stone diamond is unsurpassed. However, scientific work, especially in the last 20 years, has demonstrated that diamond has numerous surprising properties and many unique ones. Some of the extreme properties have been known for many years, but the true scale of diamond's other highly desirable features is still only coming to light as control in the synthesis of diamond, and hence material perfection, improves. The ultimate prize for man-made diamond is surely not in the synthesis of gem stones, but in delivering technological solutions enabled by diamond to the challenges facing our society today. If the special properties are to be exploited to their full potential, at least four crucial factors must be considered. First, there must be sufficient scientific understanding of diamond to make applications effective, efficient and economical. Secondly, the means of fabrication and control of properties have to be achieved so that diamond's role can be optimised. Thirdly, it is not enough that its properties are superior to existing materials: they must be so much better that it is worth initiating new technologies to exploit them. Finally, any substantial applications will have to address the society's major needs worldwide. The clear technology drivers for the 21st century come from the biomedical technologies, the demand for energy subject to global constraints, and the information technologies, where perhaps diamond will provide the major enabling technology [1]. The papers in this volume concern the solid state physics of diamond, and primarily concern the first two factors: understanding, and control of properties. They address many of the outstanding basic problems, such as the identification of existing defects, which affect the material's properties, both desirable and less so. Regarding future substantial applications, one paper discusses

  14. Gaseous elemental mercury (GEM) fluxes over canopy of two typical subtropical forests in south China

    Science.gov (United States)

    Yu, Qian; Luo, Yao; Wang, Shuxiao; Wang, Zhiqi; Hao, Jiming; Duan, Lei

    2018-01-01

    Mercury (Hg) exchange between forests and the atmosphere plays an important role in global Hg cycling. The present estimate of global emission of Hg from natural source has large uncertainty, partly due to the lack of chronical and valid field data, particularly for terrestrial surfaces in China, the most important contributor to global atmospheric Hg. In this study, the micrometeorological method (MM) was used to continuously observe gaseous elemental mercury (GEM) fluxes over forest canopy at a mildly polluted site (Qianyanzhou, QYZ) and a moderately polluted site (Huitong, HT, near a large Hg mine) in subtropical south China for a full year from January to December in 2014. The GEM flux measurements over forest canopy in QYZ and HT showed net emission with annual average values of 6.67 and 0.30 ng m-2 h-1, respectively. Daily variations of GEM fluxes showed an increasing emission with the increasing air temperature and solar radiation in the daytime to a peak at 13:00, and decreasing emission thereafter, even as a GEM sink or balance at night. High temperature and low air Hg concentration resulted in the high Hg emission in summer. Low temperature in winter and Hg absorption by plant in spring resulted in low Hg emission, or even adsorption in the two seasons. GEM fluxes were positively correlated with air temperature, soil temperature, wind speed, and solar radiation, while it is negatively correlated with air humidity and atmospheric GEM concentration. The lower emission fluxes of GEM at the moderately polluted site (HT) when compared with that in the mildly polluted site (QYZ) may result from a much higher adsorption fluxes at night in spite of a similar or higher emission fluxes during daytime. This shows that the higher atmospheric GEM concentration at HT restricted the forest GEM emission. Great attention should be paid to forests as a crucial increasing Hg emission source with the decreasing atmospheric GEM concentration in polluted areas because of Hg

  15. The stable K0 giant star β Gem

    Energy Technology Data Exchange (ETDEWEB)

    Gray, David F., E-mail: dfgray@uwo.ca [Department of Physics and Astronomy, University of Western Ontario, 1151 Richmond Street, London, Ontario, N6A 3K7 (Canada)

    2014-12-01

    A nine-season spectroscopic study of the photosphere of β Gem (K0 III) shows this low-luminosity giant to be stable, with no effective temperature variations above ∼2 K, and no secular temperature variations over the 2002-2010 time span above 0.2 K per year. The radial-velocity variations are consistent with an orbital variation of ∼40 m s{sup –1}. The projected rotation rate is found to be 1.70 ± 0.20 km s{sup –1} with a macroturbulence dispersion of 4.53 ± 0.10 km s{sup –1}. The third-signature plot is also invariant and shows a granulation velocity gradient 20% smaller than the solar gradient. The absolute shift of the third-signature plot gives a blueshift-corrected radial velocity of 3385 ± 70 m s{sup –1}. Bisector mapping of the Fe I λ6253 line yields a flux deficit of 12% ± 1% in area, somewhat smaller than for other giants, but the shape and the position of the peak at 4.8 km s{sup –1} is consistent with other giants. All of the investigated photospheric parameters are consistent with β Gem being a low-luminosity giant in agreement with its absolute magnitude.

  16. Does classroom amplification aid comprehension?

    Science.gov (United States)

    Arnold, P; Canning, D

    1999-06-01

    Many classrooms are noisy and this interferes with listening and teaching. FM soundfield (FM) amplification systems have been developed which provide a uniform soundfield throughout the classroom and increase the speech-signal:noise ratio. The effect on comprehension of such a system was investigated. Forty-nine pupils (comprising the two top classes of a mainstream primary school) participated in this study, with a mean age of 9.92 years (range 8.58-11.42 years). The Neale Analysis of Reading Ability (Neale, 1988a, b) was modified and administered as a spoken comprehension test. Tests of nonverbal intelligence, auditory memory and a questionnaire were given. The passages spoken though the FM amplification system were understood better than the comparable unamplified passages. Auditory memory, sex and non-verbal intelligence had no effect on improved comprehension. FM amplification significantly improved comprehension and could be considered for use in other schools.

  17. GEM-AQ/EC, an on-line global multi-scale chemical weather modelling system: model development and evaluation of global aerosol climatology

    Directory of Open Access Journals (Sweden)

    S. L. Gong

    2012-09-01

    Full Text Available A global air quality modeling system GEM-AQ/EC was developed by implementing tropospheric chemistry and aerosol processes on-line into the Global Environmental Multiscale weather prediction model – GEM. Due to the multi-scale features of the GEM, the integrated model, GEM-AQ/EC, is able to investigate chemical weather at scales from global to urban domains. The current chemical mechanism is comprised of 50 gas-phase species, 116 chemical and 19 photolysis reactions, and is complemented by a sectional aerosol module CAM (The Canadian Aerosol Module with 5 aerosols types: sulphate, black carbon, organic carbon, sea-salt and soil dust. Monthly emission inventories of black carbon and organic carbon from boreal and temperate vegetation fires were assembled using the most reliable areas burned datasets by countries, from statistical databases and derived from remote sensing products of 1995–2004. The model was run for ten years from from 1995–2004 with re-analyzed meteorology on a global uniform 1° × 1° horizontal resolution domain and 28 hybrid levels extending up to 10 hPa. The simulating results were compared with various observations including surface network around the globe and satellite data. Regional features of global aerosols are reasonably captured including emission, surface concentrations and aerosol optical depth. For various types of aerosols, satisfactory correlations were achieved between modeled and observed with some degree of systematic bias possibly due to large uncertainties in the emissions used in this study. A global distribution of natural aerosol contributions to the total aerosols is obtained and compared with observations.

  18. Bedeutung des Gemüsebaus für die Landwirtschaft von Wielkopolska

    Directory of Open Access Journals (Sweden)

    Karolina Jąder

    2009-01-01

    Full Text Available In dem Artikel wurde die Bedeutung des Gemüsebaus für die Landwirtschaft der Region Wielkopolska präsentiert. Diese Bedeutung wurde mit Hilfe von einigen Kriterien bestimmt. Es wurden dargestellt: der Anteil der Gemüsefläche an der gesamten landwirtschaftlichen Nutzfläche von Wielkopolska und der Gemüseanteil in der Brutto- und Warenproduktion der regionalen Landwirtschaft und der Pflanzenabteilung. Der Anteil der Freilandgemüsefläche an der landwirtschaftlichen Nutzfläche lag bei 1,36 bis 1,56 Prozent und der Anteil der Gewächshausgemüsefläche an der landwirtschaftlichen Nutzfläche oszillierte von 0,017 bis 0,050 Prozent. Die Gemüseproduktion lag bei 4,67 Prozent der Bruttoproduktion der Landwirtschaft von Wielkopolska, und der Anteil der Gemüseproduktion an der Warenproduktion der Landwirtschaft war in der Zeit auf einem ähnlichen Niveau – 4,66 Prozent. In der Pflanzenabteilung war die Bedeutung des Gemüsebaus noch größer als in der ganzen Landwirtschaft. Der Anteil von Gemüse an der Warenproduktion der Pflanzenabteilung lag durchschnittlich in den untersuchten Jahren bei 28, 54 Prozent.

  19. Raman Amplification with a Flying Focus

    Science.gov (United States)

    Turnbull, D.; Bucht, S.; Davies, A.; Haberberger, D.; Kessler, T.; Shaw, J. L.; Froula, D. H.

    2018-01-01

    We propose a new laser amplifier scheme utilizing stimulated Raman scattering in plasma in conjunction with a "flying focus"—a chromatic focusing system combined with a chirped pump beam that provides spatiotemporal control over the pump's focal spot. Pump intensity isosurfaces are made to propagate at v =-c so as to be in sync with the injected counterpropagating seed pulse. By setting the pump intensity in the interaction region to be just above the ionization threshold of the background gas, an ionization wave is produced that travels at a fixed distance ahead of the seed. Simulations show that this will make it possible to optimize the plasma temperature and mitigate many of the issues that are known to have impacted previous Raman amplification experiments, in particular, the growth of precursors.

  20. Lingua(gem sob duas perspectivas teóricas

    Directory of Open Access Journals (Sweden)

    Lidiomar José Mascarello

    2010-02-01

    Destacaremos nesse breve percurso teórico dois olhares possíveis para esse fenômeno, a língua(gem, que é tão natural e ao mesmo tempo tão complexo de ser explicado e entendido. De um lado, questões psíquicas individuais, como um processo evolutivo que opera em escala de tempo e que depende da maturação dos processos neurais e de toda rede neuronial e da capacidade inata do sujeito, ou seja, uma visão com tendências mais cognitivista, e por outro, da exposição à interação sócio-ambiental, de cunho interacionista, pois, acreditamos que são complementares e não restritivas ou excludentes.

  1. GEM 10B Satellite gravity data and Nigerian oil prospects

    International Nuclear Information System (INIS)

    Garde, S.C.; Kim, W.Y.

    1984-11-01

    Extension of the hydrocarbon rich Benue depression and the Niger delta basin in the bight of Benin is construed from the gravity data of Gravity Earth Model (GEM) 10B Satellite, published by NASA, Godard Space Flight Centre in 1977. This interpretation is based on the supposition that: i) the depth of a buried horizontal cylinder can be estimated by the Fourier transform of the vertical gravity field [Odegard and Berg, Geophys., 30, No. 3, 424-438 (1965)]; and ii) the oil horizons of southern Nigeria are basically connected to the separation of South American and African plates [Burke et al., African Geology, Ibadan Univ. Press, Ibadan, Nigeria, p. 187-204 (1970)]. (author)

  2. The Triple GEM Detector Control System for CMS forward muon spectrometer upgrade

    OpenAIRE

    CMS Collaboration; Canelli, Florencia; Kilminster, Benjamin; Aarestad, Thea; Caminada, Lea; de Cosa, Annapaoloa; Del Burgo, Riccardo; Donato, Silvio; Galloni, Camilla; Hinzmann, Andreas; Hreus, Tomas; Ngadiuba, Jennifer; Pinna, Deborah; Rauco, Giorgia; Robmann, Peter

    2017-01-01

    The CMS experiment at LHC will upgrade its forward muon spectrometer by incorporating Triple-GEM detectors. This upgrade referred to as GEM Endcap (GE1/1), consists of adding two back-to-back Triple-GEM detectors in front of the existing Cathode Strip Chambers (CSC) in the innermost ring of the endcap muon spectrometer. Before the full installation of 144 detectors in 2019–2020, CMS will first install ten single chamber prototypes during the early 2017. This pre-installation is referred as th...

  3. The development of neutron detectors for the GEM instrument at ISIS

    Energy Technology Data Exchange (ETDEWEB)

    Rhodes, N.J.; Johnson, M.W.; Schooneveld, E.M. [ISIS Facility, Rutherford Appleton Laboratory, Chilton, Didcot, Oxon (United Kingdom)

    2001-03-01

    GEM is a new General Materials diffractometer now being commissioned at ISIS. To meet its broad based scientific programme GEM requires a large area position sensitive detector which covers a wide range of scattering angles and exhibits a high neutron count rate stability. This paper discusses the design of a ZnS/{sup 6}Li fibre coupled detector array that meets the GEM requirements. Typical detector characteristics are documented together with the current status of the project. Two thirds of the detector array are operational and from the results obtained to date it is already obvious that the impact of this instrument on neutron scattering studies will be profound. (author)

  4. Editorial: Reviewer Selection Process and New Areas of Expertise in GEMS

    Science.gov (United States)

    Liemohn, Michael W.; Balikhin, Michael; Kepko, Larry; Rodger, Alan; Wang, Yuming

    2016-01-01

    One method of selecting potential reviewers for papers submitted to the Journal of Geophysical Research Space Physics is to filter the user database within the Geophysical Electronic Manuscript System (GEMS) by areas of expertise. The list of these areas in GEMS can be self selected by users in their profile settings. The Editors have added 18 new entries to this list, an increase of 33 more than the previous 55 entries. All space physicists are strongly encouraged to update their profile settings in GEMS, especially their areas of expertise selections, and details of how to do this are provided.

  5. Reliability of point-of-care hematocrit, blood gas, electrolyte, lactate and glucose measurement during cardiopulmonary bypass.

    Science.gov (United States)

    Steinfelder-Visscher, J; Weerwind, P W; Teerenstra, S; Brouwer, M H J

    2006-01-01

    Recently, the GEM Premier blood gas analyser was upgraded to the GEM Premier 3000. In addition to pH, pCO2, pO2, Na+, K+, Ca2+, and hematocrit measurement, glucose and lactate can be measured on the GEM Premier 3000. In this prospective clinical study, the analytical performance of the GEM Premier 3000 was compared with the Ciba Corning 865 analyser for blood gas/electrolytes/metabolites, and for hematocrit with the Sysmex XE 2100 instrument. During a 6-month period, 127 blood samples were analysed on both the GEM Premier 3000 analyser and our laboratory analysers (Ciba Corning 865/Sysmex 2100 instrument), and compared using the agreement analysis for quantitative data. With the exception of K+, the other parameters (pCO2, pO2, Na+, Ca2+, hematocrit, glucose, and lactate) can be described in terms of the mean and standard deviation of the differences. For K+ measurement, a clear linear trend (r=0.79, preference range, the GEM Premier 3000 measured systematically too low or too high, respectively. Furthermore, in comparison with the other parameters, a therapeutically unacceptable systematic difference (mean of difference: -2.2%, p=0.05) in hematocrit measurement on the GEM Premier 3000 was observed for hematocrit values below 30%. The variance of the readings for the GEM Premier 3000 measurements was at clinically acceptable levels. The GEM Premier 3000 analyser seems to be suitable for point-of-care testing of electrolytes, metabolites, and blood gases during cardiopulmonary bypass. However, its downward bias in hematocrit values below 30% suggests that using the GEM Premier 3000 as a transfusion trigger leads to overtreatment with packed red cells.

  6. arXiv From gated to continuous readout - the GEM upgrade of the ALICE TPC

    CERN Document Server

    Mathis, Andreas

    The ALICE Collaboration is planning a major upgrade of its central barrel detectors to be able to cope with the increased LHC luminosity beyond 2020. In order to record at an increased interaction rate of up to 50$\\,$kHz in Pb$-$Pb collisions, the TPC will be operated in an ungated mode with continuous readout. This demands for a replacement of the currently employed gated Multi-Wire Proportional Chambers by GEM-based (Gas Electron Multiplier) readout chambers, while retaining the performance in particular in terms of particle identification capabilities via the measurement of the specific energy loss. Prior to the beginning of the full mass production of the readout chambers for the upgrade, a so-called pre-production was launched in order to characterize and verify the performance of the first fully assembled readout chambers of the final design. This phase was concluded in March 2017 with the formal acceptance of the production readiness and hence the beginning of the mass production.

  7. The GEM detectors for the innermost region of the forward muon station of the LHCb experiment

    CERN Document Server

    Alfonsi, M

    The LHCb experiment will take place at the LHC accelerator at CERN and will start in 2008. It is dedicated to precision measurements of CP violation and rare decays in the b quark sec- tor. The apparatus is a single arm spectrometer and it is designed with a robust and flexible trigger in order to extensively gain access to a wide spread of differ ent physical processes involving beauty particles. This will allow to over-constrain the Standard M odel predictions about CP violation, and to discover any possible inconsistency, whi ch would reveal the presence of “New Physics” beyond the Standard Model. This thesis reports the work performed on two aspects of the L HCb experiment: the main contribution is the development and the construction of a de tector based on Gas Electron Multiplier (GEM) technology for the instrumentation of the high irradiated region around the beam pipe of the forward Muon Station; in the second part t he possibility of the search of the rare D 0 → + − decay at the LHCb exper...

  8. Genome position and gene amplification

    Czech Academy of Sciences Publication Activity Database

    Jirsová, Pavla; Snijders, A.M.; Kwek, S.; Roydasgupta, R.; Fridlyand, J.; Tokuyasu, T.; Pinkel, D.; Albertson, D. G.

    2007-01-01

    Roč. 8, č. 6 (2007), r120 ISSN 1474-760X Institutional research plan: CEZ:AV0Z50040507; CEZ:AV0Z50040702 Keywords : gene amplification * array comparative genomic hybridization * oncogene Subject RIV: BO - Biophysics Impact factor: 6.589, year: 2007

  9. Development of Large-Area GEM Detectors for the Forward Muon Endcap Upgrade of the CMS Experiment and Search for SM Higgs Boson Decay in the $H\\to\\tau^{+}\\tau^{-}\\to\\mu^{+}\\mu^{-}\\bar{\

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00366476; Gallo, Elisabetta; Raspereza, Alexei

    Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the Compact Muon Solenoid (CMS) experiment in \\mbox{Phase II} of the CERN LHC. The first GEM Endcap (GE1/1) is going to be installed in the $1.5 < \\mid\\eta\\mid < 2.2$ region of the muon endcapˆ’ mainly to control muon level-1 trigger rates after the second long LHC shutdown. A GE1/1 triple-GEM detector is read out by 3,072 radial strips with 453 $\\mu$rad pitch arranged in eight $\\eta$-sectors. A meter-long GE1/1 prototype-III was assembled at Florida Tech and tested in 20-120 GeV hadron beams at Fermilab using Ar/CO$_{2}$ 70:30 and the RD51 Scalable Readout System (SRS). Four GEM detectors with 2-D readout and an average measured azimuthal resolution of 36$\\mu$rad provided precise reference tracks. Construction of this GE1/1 prototype-III detector and its performance in the test beam are described. Strip cluster parameters, detection efficiency, and spatial resolution are studied with position and high voltag...

  10. The Efficiency of Magnetic Field Amplification at Shocks by Turbulence

    Science.gov (United States)

    Ji, Suoqing; Oh, S. Peng; Ruszkowsi, M.; Markevitch, M.

    2016-01-01

    Turbulent dynamo field amplification has often been invoked to explain the strong field strengths in thin rims in supernova shocks (approx.100 micrograms) and in radio relics in galaxy clusters (approx. micrograms). We present high-resolution magnetohydrodynamic simulations of the interaction between pre-shock turbulence, clumping and shocks, to quantify the conditions under which turbulent dynamo amplification can be significant. We demonstrate numerically converged field amplification which scales with Alfven Mach number, B/B0 varies as MA, up to MA approx.150.This implies that the post-shock field strength is relatively independent of the seed field. Amplification is dominated by compression at low MA, and stretching (turbulent amplification) at high MA. For high MA, the B-field grows exponentially and saturates at equipartition with turbulence, while the vorticity jumps sharply at the shock and subsequently decays; the resulting field is orientated predominately along the shock normal (an effect only apparent in 3D and not 2D). This agrees with the radial field bias seen in supernova remnants. By contrast, for low MA, field amplification is mostly compressional, relatively modest, and results in a predominantly perpendicular field. The latter is consistent with the polarization seen in radio relics. Our results are relatively robust to the assumed level of gas clumping. Our results imply that the turbulent dynamo may be important for supernovae, but is only consistent with the field strength, and not geometry, for cluster radio relics. For the latter, this implies strong pre-existing B-fields in the ambient cluster outskirts.

  11. Interpreting the Global Enteric Multicenter Study (GEMS Findings on Sanitation, Hygiene, and Diarrhea.

    Directory of Open Access Journals (Sweden)

    Jonny Crocker

    2016-05-01

    Full Text Available In this Perspective on the GEMS study by Kelly Baker and colleagues, Jonny Crocker and Jamie Bartram consider the implications of associations found and not found between diarrheal disease and sanitation and hygiene.

  12. Analysis of current situation of information disclosure of listed companies on GEM

    Directory of Open Access Journals (Sweden)

    Zhirong Shen

    2017-03-01

    Full Text Available In the afternoon on October 23th, 2009, GEM was officially launched in our country. Due to the lack of experience in the market supervision, information disclosure violations frequently occurred. In April 2015, Shenzhen Stock Exchange puts forward morning information disclosure system to strengthen the reform of information disclosure system. Therefore, this paper deeply focuses on the current situation of information disclosure violations on GEM for the purpose of attracting more attention to the problems. Through studying the information disclosure violations of the listed companies on GEM from 2011 to September 30th, 2015, this paper divides the violations into the following four types: false record, misleading statement, material misstatement and delayed disclosure. On the other hand, we find that these types of violations are concurrent. From this discussion, we may safely draw the conclusion that the information disclosure of listed companies on GEM has the problem of untruthfulness, incorrectness, incompleteness and delay.

  13. Measurement of spark probability of GEM detector for CBM muon chamber (MUCH)

    CERN Document Server

    Biswas, S.; Frankenfeld, U.; Garabatos, C.; Hehner, J.; Kleipa, V.; Morhardt, T.; Schmidt, C.J.; Schmidt, H.R.; Wiechula, J.

    2015-11-11

    The stability of triple GEM detector setups in an environment of high energetic showers is studied. To this end the spark probability in a shower environment is compared to the spark probability in a pion beam.

  14. Gem-diol and Ketone Crystal-to-crystal Transition Phenomena.

    Science.gov (United States)

    Bo, Zhang; Sitong, Chen; Weiming, Guo; Weijing, Zhang; Lin, Wang; Li, Yang; Jianguo, Zhang

    2017-10-18

    The generally thought unstable diol compound tetrazyl gem-diol (1, H 2 DTMdiol·2H 2 O), was firstly obtained in crystalline form by culturing the filtrate for ten days after acidification and filtration of aqueous solution of potassium salt of ketone (2, [K(HDTMone)·2H 2 O] n ). The stability of this novel gem-diol compound is found owning to the hydrogen bonds with lattice water molecules and electrophilic tetrazolyl groups. Meanwhile, the undissolved ketone (3, H 2 DTMone) was separated during the filtration in the process of gem-diol compound production. Surprisingly, the crystal-to-crystal perfect transition phenomena from gem-diol (1) to ketone (3) were firstly observed after heating up to 120  ° C as evidenced by X-ray single crystal diffraction and powder X-ray diffraction. These results found here might open new revenues for methylene oxidation and alkanediol chemistry.

  15. Financial recognition of material misstatement risks of listed companies on GEM

    OpenAIRE

    Jie Ming; Yicong Jiang

    2017-01-01

    Listed companies on GEM are characterized by strong innovation, great growth ability, high risks and high yields. Starting from these characteristics, this paper carries out analysis by using the financial indicators that are effective to recognize the material misstatement risks and easy to be acquired, and combines with the sample data with high material misstatement risks on GEM in 2012 to 2014 to test the significance of spss difference, and finds that the material misstatement company an...

  16. Geostationary Environment Monitoring Spectrometer (gems) Over the Korea Peninsula and Asia-Pacific Region

    Science.gov (United States)

    Lasnik, J.; Stephens, M.; Baker, B.; Randall, C.; Ko, D. H.; Kim, S.; Kim, Y.; Lee, E. S.; Chang, S.; Park, J. M.; SEO, S. B.; Youk, Y.; Kong, J. P.; Lee, D.; Lee, S. H.; Kim, J.

    2014-12-01

    Introduction: The Geostationary Environment Monitoring Spectrometer (GEMS) is one of two instruments manifested aboard the South Korean Geostationary Earth Orbit KOrea Multi-Purpose SATellite-2B (GEO-KOMPSAT-2B or GK2B), which is scheduled to launch in 2018. Jointly developed/built by KARI and Ball Aerospace, GEMS is a geostationary UV-Vis hyperspectral imager designed to monitor trans-boundary tropospheric pollution events over the Korean peninsula and Asia-Pacific region. The spectrometer provides high temporal and spatial resolution (3.5 km N/S by 7.2 km E/W) measurements of ozone, its precursors, and aerosols. Over the short-term, hourly measurements by GEMS will improve early warnings for potentially dangerous pollution events and monitor population exposure. Over the 10-year mission-life, GEMS will serve to enhance our understanding of long-term climate change and broader air quality issues on both a regional and global scale. The GEMS sensor design and performance are discussed, which includes an overview of measurement capabilities and the on-orbit concept of operations. GEMS Sensor Overview: The GEMS hyperspectral imaging system consists of a telescope and Offner grating spectrometer that feeds a single CCD detector array. A spectral range of 300-500 nm and sampling of 0.2 nm enables NO2, SO2, HCHO, O3, and aerosol retrieval. The GEMS field of regard (FOR), which extends from 5°S to 45°N in latitude and 75°E to 145°E in longitude, is operationally achieved using an onboard two-axis scan mirror. On-orbit, the radiometric calibration is maintained using solar measurements, which are performed using two onboard diffusers: a working diffuser that is deployed routinely for the purpose of solar calibration, and a reference diffuser that is deployed sparingly for the purpose of monitoring working diffuser performance degradation.

  17. Data Integration for Spatio-Temporal Patterns of Gene Expression of Zebrafish development: the GEMS database

    Directory of Open Access Journals (Sweden)

    Belmamoune Mounia

    2008-06-01

    Full Text Available The Gene Expression Management System (GEMS is a database system for patterns of gene expression. These patterns result from systematic whole-mount fluorescent in situ hybridization studies on zebrafish embryos. GEMS is an integrative platform that addresses one of the important challenges of developmental biology: how to integrate genetic data that underpin morphological changes during embryogenesis. Our motivation to build this system was by the need to be able to organize and compare multiple patterns of gene expression at tissue level. Integration with other developmental and biomolecular databases will further support our understanding of development. The GEMS operates in concert with a database containing a digital atlas of zebrafish embryo; this digital atlas of zebrafish development has been conceived prior to the expansion of the GEMS. The atlas contains 3D volume models of canonical stages of zebrafish development in which in each volume model element is annotated with an anatomical term. These terms are extracted from a formal anatomical ontology, i.e. the Developmental Anatomy Ontology of Zebrafish (DAOZ. In the GEMS, anatomical terms from this ontology together with terms from the Gene Ontology (GO are also used to annotate patterns of gene expression and in this manner providing mechanisms for integration and retrieval . The annotations are the glue for integration of patterns of gene expression in GEMS as well as in other biomolecular databases. At the one hand, zebrafish anatomy terminology allows gene expression data within GEMS to be integrated with phenotypical data in the 3D atlas of zebrafish development. At the other hand, GO terms extend GEMS expression patterns integration to a wide range of bioinformatics resources.

  18. The application of a monolithic triphenylphosphine reagent for conducting Ramirez gem-dibromoolefination reactions in flow.

    Science.gov (United States)

    Roper, Kimberley A; Berry, Malcolm B; Ley, Steven V

    2013-01-01

    The application of a monolithic form of triphenylphosphine to the Ramirez gem-dibromoolefination reaction using flow chemistry techniques is reported. A variety of gem-dibromides were synthesised in high purity and excellent yield following only removal of solvent and no further off-line purification. It is also possible to perform the Appel reaction using the same monolith and the relationship between the mechanisms of the two reactions is discussed.

  19. The application of a monolithic triphenylphosphine reagent for conducting Ramirez gem-dibromoolefination reactions in flow

    Directory of Open Access Journals (Sweden)

    Kimberley A. Roper

    2013-09-01

    Full Text Available The application of a monolithic form of triphenylphosphine to the Ramirez gem-dibromoolefination reaction using flow chemistry techniques is reported. A variety of gem-dibromides were synthesised in high purity and excellent yield following only removal of solvent and no further off-line purification. It is also possible to perform the Appel reaction using the same monolith and the relationship between the mechanisms of the two reactions is discussed.

  20. The Triple GEM Detector Control System for CMS forward muon spectrometer upgrade

    Science.gov (United States)

    Ahmed, W.; Abbaneo, D.; Abbrescia, M.; Abdelalim, A. A.; Abi. Akl, M.; Acosta, D.; Ahmad, A.; Ahmed, W.; Aleksandrov, A.; Aly, R.; Altieri, P.; Asawatangtrakuldee, C.; Aspell, P.; Assran, Y.; Awan, I.; Bally, S.; Ban, Y.; Banerjee, S.; Barashko, V.; Barria, P.; Bencze, G.; Beni, N.; Benussi, L.; Bhopatkar, V.; Bianco, S.; Bos, J.; Bouhali, O.; Holme, O.; Braghieri, A.; Braibant, S.; Buontempo, S.; Khan, S. A.; Calabria, C.; Caponero, M.; Caputo, C.; Cassese, F.; Castaneda, A.; Cauwenbergh, S.; Cavallo, F. R.; Celik, A.; Choi, M.; Choi, S.; Christiansen, J.; Cimmino, A.; Colafranceschi, S.; Colaleo, A.; Conde Garcia, A.; Czellar, S.; Dabrowski, M. M.; Lentdecker, G. De.; De Oliveira, R.; de Robertis, G.; Dildick, S.; Dorney, B.; Elmetenawee, W.; Endroczi, G.; Errico, F.; Fenyvesi, A.; Ferry, S.; Furic, I.; Giacomelli, P.; Gilmore, J.; Golovtsov, V.; Guiducci, L.; Guilloux, F.; Gutierrez, A.; Hadjiiska, R. M.; Hassan, A.; Hauser, J.; Hoepfner, K.; Hohlmann, M.; Hoorani, H.; Shah, A. H.; Iaydjiev, P.; Jeng, Y. G.; Kamon, T.; Karchin, P.; Korytov, A.; Krutelyov, S.; Kumar, A.; Kim, H.; Lenzi, T.; Litov, L.; Loddo, F.; Madorsky, A.; Maerschalk, T.; Maggi, M.; Magnani, A.; Mal, P. K.; Mandal, K.; Marchioro, A.; Marinov, A.; Majumdar, N.; Merlin, J. A.; Mitselmakher, G.; Mohanty, A. K.; Mohapatra, A.; Molnar, J.; Muhammad, S.; Mukhopadhyay, S.; Naimuddin, M.; Nuzzo, S.; Oliveri, E.; Pant, L. M.; Paolucci, P.; Park, I.; Passeggio, G.; Pavlov, B.; Philipps, B.; Piccolo, D.; Postema, H.; Puig. Baranac, A.; Radi, A.; Radogna, R.; Raffone, G.; Ranieri, A.; Rashevski, G.; Riccardi, C.; Rodozov, M.; Rodrigues, A.; Ropelewski, L.; RoyChowdhury, S.; Ryu, G.; Ryu, M. S.; Safonov, A.; Salva, S.; Saviano, G.; Sharma, A.; Sharma, R.; Shopova, M.; Sturdy, J.; Sultanov, G.; Swain, S. K.; Szillasi, Z.; Talvitie, J.; Tatarinov, A.; Tuuva, T.; Tytgat, M.; Vai, I.; Van Stenis, M.; Venditti, R.; Verhagen, E.; Verwilligen, P.; Vitulo, P.; Volkov, S.; Vorobyev, A.; Wang, D.; Wang, M.; Yang, U.; Yang, Y.; Yonamine, R.; Zaganidis, N.; Zenoni, F.; Zhang, A.

    2017-02-01

    The CMS experiment at LHC will upgrade its forward muon spectrometer by incorporating Triple-GEM detectors. This upgrade referred to as GEM Endcap (GE1/1), consists of adding two back-to-back Triple-GEM detectors in front of the existing Cathode Strip Chambers (CSC) in the innermost ring of the endcap muon spectrometer. Before the full installation of 144 detectors in 2019-2020, CMS will first install ten single chamber prototypes during the early 2017. This pre-installation is referred as the slice test. These ten detectors will be read-out by VFAT2 chips [1]. On-detector there is also a FPGA mezzanine card which sends VFAT2 data optically to the μTCA back-end electronics. The correct and safe operation of the GEM system requires a sophisticated and powerful online Detector Control System, able to monitor and control many heterogeneous hardware devices. The DCS system developed for the slice test has been tested with CMS Triple-GEM detectors in the laboratory. In this paper we describe the newly developed DCS system and present the first results obtained in the GEM assembly and quality assurance laboratory.

  1. Characterization of the allergen Sol gem 2 from the fire ant venom, Solenopsis geminata

    Directory of Open Access Journals (Sweden)

    S Sukprasert

    2012-01-01

    Full Text Available Sol i 2 is a potent allergen in Solenopsis invicta venom, and most humans exhibit reactivity to it. The Sol gem 2 allergen found in the venom of the Thai tropical fire ant Solenopsis geminata was analysed in the present study. The protein was present in higher amounts than other proteins, as determined by SDS-PAGE, and presumably has allergenic properties similar to those of Sol i 2. Sol gem 2 molecular weight is 28 and 15 kDa, respectively, under non-reducing and reducing conditions, indicating that its native form is a dimer. LC-MS/MS analysis confirmed its similarity to Sol i 2. The mono/dimeric form of Sol gem 2 was determined to be relevant by proteomic approach and immunoblotting. An anti-Sol gem 2 antibody was produced in mice, with a titer greater than 1:800 according to the Western blotting analysis. The Sol gem 2-neutralising activity of this antibody was determined in crickets. The paralytic dose 50 (PD50 of crude S. geminata venom was elevated from 0.18 mg/g of body weight to more than 0.90 mg/g of body weight after preincubation with antibody at a ratio of 1:1. These results suggest that Sol gem 2 plays an important role in mediating the effects of the piperidine derivatives in the venom.

  2. Fundamentals of gas counters

    International Nuclear Information System (INIS)

    Bateman, J.E.

    1994-01-01

    The operation of gas counters used for detecting radiation is explained in terms of the four fundamental physical processes which govern their operation. These are 1) conversion of neutral radiation into charged particles, 2) ionization of the host gas by a fast charge particle 3) transport of the gas ions to the electrodes and 4) amplification of the electrons in a region of enhanced electric field. Practical implications of these are illustrated. (UK)

  3. Accelerator for amplification of energy

    International Nuclear Information System (INIS)

    Mori, Yoshiharu

    1998-01-01

    As a forming method of new nuclear energy, an energy amplification system using accelerator driven subcritical reactor is focussed. In order to realize amplification of energy driven by accelerator, development of an accelerator with excellent electric power efficiency is one of the most important problems. The necessary beam power of accelerator is 10 MW, and when reducing used electric power of the accelerator to under 25% of total power generation, more than 30% of electric power efficiency is required for the accelerator. Therefore, an accelerator with excellent electric power efficiency without experiencing before now is required to realize such an aim. A prominent candidate of the accelerator is FFAG (Fixed Field Alternating Gradient) synchrotron (may be called ring synchrotron). In this paper, some simple considerations of electric power efficiency of accelerators and basic parameter of FFAG synchrotron were described. (G.K.)

  4. Laser amplification in excited dielectrics

    Science.gov (United States)

    Winkler, Thomas; Haahr-Lillevang, Lasse; Sarpe, Cristian; Zielinski, Bastian; Götte, Nadine; Senftleben, Arne; Balling, Peter; Baumert, Thomas

    2018-01-01

    Wide-bandgap dielectrics such as glasses or water are transparent at visible and infrared wavelengths. This changes when they are exposed to ultrashort and highly intense laser pulses. Different interaction mechanisms lead to the appearance of various transient nonlinear optical phenomena. Using these, the optical properties of dielectrics can be controlled from the transparent to the metal-like state. Here we expand this range by a yet unexplored mechanism in excited dielectrics: amplification. In a two-colour pump-probe experiment, we show that a 400 nm femtosecond laser pulse is coherently amplified inside an excited sapphire sample on a scale of a few micrometres. Simulations strongly support the proposed two-photon stimulated emission process, which is temporally and spatially controllable. Consequently, we expect applications in all fields that demand strongly localized amplification.

  5. Frequency domain optical parametric amplification.

    Science.gov (United States)

    Schmidt, Bruno E; Thiré, Nicolas; Boivin, Maxime; Laramée, Antoine; Poitras, François; Lebrun, Guy; Ozaki, Tsuneyuki; Ibrahim, Heide; Légaré, François

    2014-05-07

    Today's ultrafast lasers operate at the physical limits of optical materials to reach extreme performances. Amplification of single-cycle laser pulses with their corresponding octave-spanning spectra still remains a formidable challenge since the universal dilemma of gain narrowing sets limits for both real level pumped amplifiers as well as parametric amplifiers. We demonstrate that employing parametric amplification in the frequency domain rather than in time domain opens up new design opportunities for ultrafast laser science, with the potential to generate single-cycle multi-terawatt pulses. Fundamental restrictions arising from phase mismatch and damage threshold of nonlinear laser crystals are not only circumvented but also exploited to produce a synergy between increased seed spectrum and increased pump energy. This concept was successfully demonstrated by generating carrier envelope phase stable, 1.43 mJ two-cycle pulses at 1.8 μm wavelength.

  6. Laser amplification in excited dielectrics

    DEFF Research Database (Denmark)

    Winkler, Thomas; Haahr-Lillevang, Lasse; Sarpe, Cristian

    2018-01-01

    Wide-bandgap dielectrics such as glasses or water are transparent at visible and infrared wavelengths. This changes when they are exposed to ultrashort and highly intense laser pulses. Different interaction mechanisms lead to the appearance of various transient nonlinear optical phenomena. Using...... these, the optical properties of dielectrics can be controlled from the transparent to the metal-like state. Here we expand this range by a yet unexplored mechanism in excited dielectrics: amplification. In a two-colour pump-probe experiment, we show that a 400nm femtosecond laser pulse is coherently...... amplified inside an excited sapphire sample on a scale of a few micrometres. Simulations strongly support the proposed two-photon stimulated emission process, which is temporally and spatially controllable. Consequently, we expect applications in all fields that demand strongly localized amplification....

  7. Differential voltage amplification from ferroelectric negative capacitance

    Science.gov (United States)

    Khan, Asif I.; Hoffmann, Michael; Chatterjee, Korok; Lu, Zhongyuan; Xu, Ruijuan; Serrao, Claudy; Smith, Samuel; Martin, Lane W.; Hu, Chenming; Ramesh, Ramamoorthy; Salahuddin, Sayeef

    2017-12-01

    We demonstrate that a ferroelectric can cause a differential voltage amplification without needing an external energy source. As the ferroelectric switches from one polarization state to the other, a transfer of energy takes place from the ferroelectric to the dielectric, determined by the ratio of their capacitances, which, in turn, leads to the differential amplification. This amplification is very different in nature from conventional inductor-capacitor based circuits where an oscillatory amplification can be observed. The demonstration of differential voltage amplification from completely passive capacitor elements only has fundamental ramifications for next generation electronics.

  8. Evaluation of ozone profile and tropospheric ozone retrievals from GEMS and OMI spectra

    Directory of Open Access Journals (Sweden)

    J. Bak

    2013-02-01

    Full Text Available South Korea is planning to launch the GEMS (Geostationary Environment Monitoring Spectrometer instrument into the GeoKOMPSAT (Geostationary Korea Multi-Purpose SATellite platform in 2018 to monitor tropospheric air pollutants on an hourly basis over East Asia. GEMS will measure backscattered UV radiances covering the 300–500 nm wavelength range with a spectral resolution of 0.6 nm. The main objective of this study is to evaluate ozone profiles and stratospheric column ozone amounts retrieved from simulated GEMS measurements. Ozone Monitoring Instrument (OMI Level 1B radiances, which have the spectral range 270–500 nm at spectral resolution of 0.42–0.63 nm, are used to simulate the GEMS radiances. An optimal estimation-based ozone profile algorithm is used to retrieve ozone profiles from simulated GEMS radiances. Firstly, we compare the retrieval characteristics (including averaging kernels, degrees of freedom for signal, and retrieval error derived from the 270–330 nm (OMI and 300–330 nm (GEMS wavelength ranges. This comparison shows that the effect of not using measurements below 300 nm on retrieval characteristics in the troposphere is insignificant. However, the stratospheric ozone information in terms of DFS decreases greatly from OMI to GEMS, by a factor of ∼2. The number of the independent pieces of information available from GEMS measurements is estimated to 3 on average in the stratosphere, with associated retrieval errors of ~1% in stratospheric column ozone. The difference between OMI and GEMS retrieval characteristics is apparent for retrieving ozone layers above ~20 km, with a reduction in the sensitivity and an increase in the retrieval errors for GEMS. We further investigate whether GEMS can resolve the stratospheric ozone variation observed from high vertical resolution Earth Observing System (EOS Microwave Limb Sounder (MLS. The differences in stratospheric ozone profiles between GEMS and MLS are comparable to those

  9. Spheromak Impedance and Current Amplification

    International Nuclear Information System (INIS)

    Fowler, T K; Hua, D D; Stallard, B W

    2002-01-01

    It is shown that high current amplification can be achieved only by injecting helicity on the timescale for reconnection, τ REC , which determines the effective impedance of the spheromak. An approximate equation for current amplification is: dI TOR 2 /dt ∼ I 2 /τ REC - I TOR 2 /τ closed where I is the gun current, I TOR is the spheromak toroidal current and τ CLOSED is the ohmic decay time of the spheromak. Achieving high current amplification, I TOR >> I, requires τ REC CLOSED . For resistive reconnection, this requires reconnection in a cold zone feeding helicity into a hot zone. Here we propose an impedance model based on these ideas in a form that can be implemented in the Corsica-based helicity transport code. The most important feature of the model is the possibility that τ REC actually increases as the spheromak temperature increases, perhaps accounting for the ''voltage sag'' observed in some experiments, and a tendency toward a constant ratio of field to current, B ∝ I, or I TOR ∼ I. Program implications are discussed

  10. GEM*STAR: Time for an Alternative Way Forward

    Science.gov (United States)

    Vogelaar, R. Bruce

    2011-10-01

    The presumption that nuclear reactors will retain their role in global energy production is constantly being challenged - even more so following recent events at Fukushima. Nuclear energy, despite being ``green,'' has inexorably been coupled in the public mind with three paramount concerns: safety, weapons proliferation, and waste (and then ultimately cost). Over the past four decades, the safety of deployed fleets has greatly improved, yet the capital and political costs of a ``nuclear energy option'' appear insurmountable in several countries. The US approach to civilian nuclear energy has become deeply entrenched, first through choices made by the military, and then by the deployed nuclear reactor fleet. This extends to the research agencies as well, to the point where basic sciences and nuclear energy operate in separate spheres. But technologies and priorities have changed, and the time has arrived where a transformative re-think of nuclear energy is not only possible, but urgent. And nuclear physicists are uniquely positioned to accomplish this. This talk will show that by asking, and answering,``what would an accelerator-driven civilian nuclear energy program look like,'' ADNA Corporation's GEM*STAR design directly addresses all three fundamental concerns: safety, proliferation, and waste - and also the final hurdle: cost. GEM*STAR is not an ``add-on'' (to either Project-X, or GEN III+), but rather a base-line energy production capacity, for either electricity or transport fuel production. It integrates and advances the molten-salt reactor technology developed at ORNL, the MW beam accelerator technologies developed by basic sciences, and a reactor/target design optimized for accelerator driven-systems. The results include: the ability to use LWR spent fuel without reprocessing or additional waste; the ability to use natural uranium; no critical mass ever present; orders-of-magnitude less volatile radioactivity in the core; more efficient use of, and deeper

  11. Experiment study on the thick GEM-like multiplier for X-ray photoelectrons energy deposition gaining

    International Nuclear Information System (INIS)

    Zhu Pengfei; Ye Yan; Long Yan; Cao Ningxiang; Jia Xing; Li Jianfeng

    2009-01-01

    The GEM is a novel detector with high gain,high time and location resolution. Imitating the structure of the GEM, a thick GEM-like multiplier which has the similar function with that of the GEM is designed and manufactured. The characteristics of the thick GEM-like multiplier increasing electron energy deposition in absorbing medium has been experimentally studied. The results indicate that the energy deposition gain of x-ray photoelectron in medium is apparent, and the maximum energy deposition can increase by more than 40%. Some suggestions of further increasing the energy deposition are given, and the future application of the way of increasing the x-ray photoelectron energy deposition by the thick GEM-like multiplier in hard x-ray imaging is prospected. (authors)

  12. Heavy Ion and Proton Irradiation of Gas Electron Multipliers With Liquid Crystal Polymer Insulator: Evaluation Tests for Use in Space

    Science.gov (United States)

    Iwahashi, T.; Tamagawa, T.; Hayato, A.; Nakamura, S.; Konami, S.; Asami, F.; Yasuda, N.; Kitamura, H.; Sakurai, H.; Tokanai, F.; Miyasaka, H.; Makishima, K.

    2011-10-01

    Gas electron multipliers with a liquid crystal polymer insulator (LCP-GEMs) can be employed as X-ray polarimeters in several satellite missions in low-earth orbit. To evaluate their resistance to radiation, LCP-GEMs were exposed to Fe ion and proton beams from the heavy-ion accelerator facility HIMAC, and the gas gain was monitored. The LCP-GEMs survived 14.4-year-equivalent irradiation by fully stripped Fe ions with an energy of 500 MeV nuc-1, which simulated galactic cosmic-ray ions. We also studied the degradation of the insulator layer of the LCP-GEMs by irradiation with 160 MeV protons to simulate geomagnetically trapped protons. After irradiation with protons for 31.6 years equivalent, no significant change in gain was observed.

  13. An Interactive Java Statistical Image Segmentation System: GemIdent.

    Science.gov (United States)

    Holmes, Susan; Kapelner, Adam; Lee, Peter P

    2009-06-01

    Supervised learning can be used to segment/identify regions of interest in images using both color and morphological information. A novel object identification algorithm was developed in Java to locate immune and cancer cells in images of immunohistochemically-stained lymph node tissue from a recent study published by Kohrt et al. (2005). The algorithms are also showing promise in other domains. The success of the method depends heavily on the use of color, the relative homogeneity of object appearance and on interactivity. As is often the case in segmentation, an algorithm specifically tailored to the application works better than using broader methods that work passably well on any problem. Our main innovation is the interactive feature extraction from color images. We also enable the user to improve the classification with an interactive visualization system. This is then coupled with the statistical learning algorithms and intensive feedback from the user over many classification-correction iterations, resulting in a highly accurate and user-friendly solution. The system ultimately provides the locations of every cell recognized in the entire tissue in a text file tailored to be easily imported into R (Ihaka and Gentleman 1996; R Development Core Team 2009) for further statistical analyses. This data is invaluable in the study of spatial and multidimensional relationships between cell populations and tumor structure. This system is available at http://www.GemIdent.com/ together with three demonstration videos and a manual.

  14. An efficient and general route to gem-difluoromethylenated alpha,beta-unsaturated delta-lactones: high enantioselective synthesis of gem-difluoromethylenated goniothalamins.

    Science.gov (United States)

    You, Zheng-Wei; Jiang, Zhong-Xing; Wang, Bing-Lin; Qing, Feng-Ling

    2006-09-15

    An efficient and general strategy to gem-difluoromethylenated alpha,beta-unsaturated delta-lactones in high yields from various aldehydes (including aliphatic, aromatic, alpha,beta-unsaturated, and sterically hindered aldehydes) has been developed. This methodology was successfully applied for the preparation of two enantiomers of gem-difluoromethylenated goniothalamins (S)-1 and (R)-1. gem-Difluoropropargylation of cinnamaldehyde followed by the resolution of resulting homopropargylic alcohols mediated by lipase from Pseudomonas (AK) gave alcohols (R)-6 and (S)-6. Selective hydrogenation of the triple bond of (S)-6 and (R)-6 to double bond with Lindlar catalyst in the presence of quinoline afforded the expected product (S)-8 and (R)-8, respectively. Deprotection of (S)-8 and (R)-8 followed by oxidation of the resulting 1,5-diols with catalytic 2,2,6,6-tetramethyl-1-piperidinyloxy (TEMPO) and excess bis-acetoxyiodobenzene (BAIB) provided the target molecules gem-difluoromethylenated goniothalamins (S)-1 and (R)-1 in high yields, respectively.

  15. The Operational Experience of the Triple-GEM Detectors of the LHCb Muon System: Summary of 2 Years of Data Taking

    CERN Document Server

    Cardini, Alessandro; De Simone, Patrizia

    2012-01-01

    The LHCb muon system consists of more than a thousand gas detectors, mostly MWPC, located in five different stations. The Muon detector is used to define the muon trigger and to identify muons at the high-level triger and at the recontruction stage. The first station of the muon detector, located in front of the calorimetric system, is made of 274 chambers. The 12 most irradiated chambers, the ones closer to the beam pipe, are double triple-GEM detectors with pad readout. These detectors have an active area of 200x240 mm$^2$ and are routinely operated at rates close to 300 kHz/cm$^2$. With the gas mixture used (Ar/CO$_2$/CF$_4$ at 45/15/40) these detectors have the requested efficiency (>96% in a 20 ns time window for the logical OR of the two sensitive gaps) when operated at gains of about 2300. In this presentation we will report on the performance of these 24 triple-GEM detectors after more than 2 years of operation in the harsh LHCb conditions. We will also show some problems occurred during data taking, ...

  16. Resonant primordial gravitational waves amplification

    Directory of Open Access Journals (Sweden)

    Chunshan Lin

    2016-01-01

    Full Text Available We propose a mechanism to evade the Lyth bound in models of inflation. We minimally extend the conventional single-field inflation model in general relativity (GR to a theory with non-vanishing graviton mass in the very early universe. The modification primarily affects the tensor perturbation, while the scalar and vector perturbations are the same as the ones in GR with a single scalar field at least at the level of linear perturbation theory. During the reheating stage, the graviton mass oscillates coherently and leads to resonant amplification of the primordial tensor perturbation. After reheating the graviton mass vanishes and we recover GR.

  17. Serial data acquisition for the X-ray plasma diagnostics with selected GEM detector structures

    International Nuclear Information System (INIS)

    Czarski, T.; Chernyshova, M.; Pozniak, K.T.; Kasprowicz, G.; Zabolotny, W.; Kolasinski, P.; Krawczyk, R.; Wojenski, A.; Zienkiewicz, P.

    2015-01-01

    The measurement system based on GEM—Gas Electron Multiplier detector is developed for X-ray diagnostics of magnetic confinement tokamak plasmas. The paper is focused on the measurement subject and describes the fundamental data processing to obtain reliable characteristics (histograms) useful for physicists. The required data processing have two steps: 1—processing in the time domain, i.e. events selections for bunches of coinciding clusters, 2—processing in the planar space domain, i.e. cluster identification for the given detector structure. So, it is the software part of the project between the electronic hardware and physics applications. The whole project is original and it was developed by the paper authors. The previous version based on 1-D GEM detector was applied for the high-resolution X-ray crystal spectrometer KX1 in the JET tokamak. The current version considers 2-D detector structures for the new data acquisition system. The fast and accurate mode of data acquisition implemented in the hardware in real time can be applied for the dynamic plasma diagnostics. Several detector structures with single-pixel sensors and multi-pixel (directional) sensors are considered for two-dimensional X-ray imaging. Final data processing is presented by histograms for selected range of position, time interval and cluster charge values. Exemplary radiation source properties are measured by the basic cumulative characteristics: the cluster position distribution and cluster charge value distribution corresponding to the energy spectra. A shorter version of this contribution is due to be published in PoS at: 1 st EPS conference on Plasma Diagnostics

  18. Serial data acquisition for the X-ray plasma diagnostics with selected GEM detector structures

    Science.gov (United States)

    Czarski, T.; Chernyshova, M.; Pozniak, K. T.; Kasprowicz, G.; Zabolotny, W.; Kolasinski, P.; Krawczyk, R.; Wojenski, A.; Zienkiewicz, P.

    2015-10-01

    The measurement system based on GEM—Gas Electron Multiplier detector is developed for X-ray diagnostics of magnetic confinement tokamak plasmas. The paper is focused on the measurement subject and describes the fundamental data processing to obtain reliable characteristics (histograms) useful for physicists. The required data processing have two steps: 1—processing in the time domain, i.e. events selections for bunches of coinciding clusters, 2—processing in the planar space domain, i.e. cluster identification for the given detector structure. So, it is the software part of the project between the electronic hardware and physics applications. The whole project is original and it was developed by the paper authors. The previous version based on 1-D GEM detector was applied for the high-resolution X-ray crystal spectrometer KX1 in the JET tokamak. The current version considers 2-D detector structures for the new data acquisition system. The fast and accurate mode of data acquisition implemented in the hardware in real time can be applied for the dynamic plasma diagnostics. Several detector structures with single-pixel sensors and multi-pixel (directional) sensors are considered for two-dimensional X-ray imaging. Final data processing is presented by histograms for selected range of position, time interval and cluster charge values. Exemplary radiation source properties are measured by the basic cumulative characteristics: the cluster position distribution and cluster charge value distribution corresponding to the energy spectra. A shorter version of this contribution is due to be published in PoS at: 1st EPS conference on Plasma Diagnostics

  19. USERS MANUAL: LANDFILL GAS EMISSIONS MODEL - VERSION 2.0

    Science.gov (United States)

    The document is a user's guide for a computer model, Version 2.0 of the Landfill Gas Emissions Model (LandGEM), for estimating air pollution emissions from municipal solid waste (MSW) landfills. The model can be used to estimate emission rates for methane, carbon dioxide, nonmet...

  20. The HadGEM2 family of Met Office Unified Model climate configurations

    Directory of Open Access Journals (Sweden)

    The HadGEM2 Development Team: G. M. Martin

    2011-09-01

    Full Text Available We describe the HadGEM2 family of climate configurations of the Met Office Unified Model, MetUM. The concept of a model "family" comprises a range of specific model configurations incorporating different levels of complexity but with a common physical framework. The HadGEM2 family of configurations includes atmosphere and ocean components, with and without a vertical extension to include a well-resolved stratosphere, and an Earth-System (ES component which includes dynamic vegetation, ocean biology and atmospheric chemistry. The HadGEM2 physical model includes improvements designed to address specific systematic errors encountered in the previous climate configuration, HadGEM1, namely Northern Hemisphere continental temperature biases and tropical sea surface temperature biases and poor variability. Targeting these biases was crucial in order that the ES configuration could represent important biogeochemical climate feedbacks. Detailed descriptions and evaluations of particular HadGEM2 family members are included in a number of other publications, and the discussion here is limited to a summary of the overall performance using a set of model metrics which compare the way in which the various configurations simulate present-day climate and its variability.

  1. The role of evaporites in the formation of gems during metamorphism of carbonate platforms: a review

    Science.gov (United States)

    Giuliani, Gaston; Dubessy, Jean; Ohnenstetter, Daniel; Banks, David; Branquet, Yannick; Feneyrol, Julien; Fallick, Anthony E.; Martelat, Jean-Emmanuel

    2018-01-01

    The mineral and fluid inclusions trapped by gemstones during the metamorphism of carbonate platform successions are precious markers for the understanding of gem genesis. The nature and chemical composition of inclusions highlight the major contribution of evaporites through dissolution or fusion, depending on the temperature of formation from greenschist to granulite facies. The fluids are highly saline NaCl-brines circulating either in an open system in the greenschist facies (Colombian and Afghan emeralds) and with huge fluid-rock metasomatic interactions, or sulphurous fluids (ruby, garnet tsavorite, zoisite tanzanite and lapis-lazuli) or molten salts formed in a closed system with a low fluid mobility (ruby in marble) in the conditions of the amphibolite to granulite facies. These chloride-fluoride-sulphate ± carbonate-rich fluids scavenged the metals essential for gem formation. At high temperature, the anions SO4 2-, NO3 -, BO3 - and F- are powerful fluxes which lower the temperature of chloride- and fluoride-rich ionic liquids. They provided transport over a very short distance of aluminium and/or silica and transition metals which are necessary for gem growth. In summary, the genetic models proposed for these high-value and ornamental gems underline the importance of the metamorphism of evaporites formed on continental carbonate shelves and emphasise the chemical power accompanying metamorphism at moderate to high temperatures of evaporite-rich and organic matter-rich protoliths to form gem minerals.

  2. Chirped pulse Raman amplification in plasma

    Energy Technology Data Exchange (ETDEWEB)

    Vieux, G; Lyachev, A; Yang, X; Ersfeld, B; Farmer, J P; Brunetti, E; Issac, R C; Raj, G; Welsh, G H; Wiggins, S M; Jaroszynski, D A, E-mail: d.a.jaroszynski@strath.ac.uk [Department of Physics, Scottish Universities Physics Alliance, University of Strathclyde, Glasgow G4 0NG (United Kingdom)

    2011-06-15

    Raman amplification in plasma has been proposed to be a promising method of amplifying short radiation pulses. Here, we investigate chirped pulse Raman amplification (CPRA) where the pump pulse is chirped and leads to spatiotemporal distributed gain, which exhibits superradiant scaling in the linear regime, usually associated with the nonlinear pump depletion and Compton amplification regimes. CPRA has the potential to serve as a high-efficiency high-fidelity amplifier/compressor stage.

  3. Review of GEM Radiation Belt Dropout and Buildup Challenges

    Science.gov (United States)

    Tu, Weichao; Li, Wen; Morley, Steve; Albert, Jay

    2017-04-01

    In Summer 2015 the US NSF GEM (Geospace Environment Modeling) focus group named "Quantitative Assessment of Radiation Belt Modeling" started the "RB dropout" and "RB buildup" challenges, focused on quantitative modeling of the radiation belt buildups and dropouts. This is a community effort which includes selecting challenge events, gathering model inputs that are required to model the radiation belt dynamics during these events (e.g., various magnetospheric waves, plasmapause and density models, electron phase space density data), simulating the challenge events using different types of radiation belt models, and validating the model results by comparison to in situ observations of radiation belt electrons (from Van Allen Probes, THEMIS, GOES, LANL/GEO, etc). The goal is to quantitatively assess the relative importance of various acceleration, transport, and loss processes in the observed radiation belt dropouts and buildups. Since 2015, the community has selected four "challenge" events under four different categories: "storm-time enhancements", "non-storm enhancements", "storm-time dropouts", and "non-storm dropouts". Model inputs and data for each selected event have been coordinated and shared within the community to establish a common basis for simulations and testing. Modelers within and outside US with different types of radiation belt models (diffusion-type, diffusion-convection-type, test particle codes, etc.) have participated in our challenge and shared their simulation results and comparison with spacecraft measurements. Significant progress has been made in quantitative modeling of the radiation belt buildups and dropouts as well as accessing the modeling with new measures of model performance. In this presentation, I will review the activities from our "RB dropout" and "RB buildup" challenges and the progresses achieved in understanding radiation belt physics and improving model validation and verification.

  4. Applications of Mapping and Tomographic Techniques in Gem Sciences

    Science.gov (United States)

    Shen, A. H.

    2014-12-01

    Gem Sciences are scientific studies of gemstones - their genesis, provenance, synthesis, enhancement, treatment and identification. As high quality forms of specific minerals, the gemstones exhibit unusual physical properties that are usually unseen in the regular counterparts. Most gemstones are colored by trace elements incorporated in the crystal lattice during various growth stages; forming coloration zones of various scales. Studying the spectral and chemical contrast across color zones helps elucidating the origins of colors. These are done by UV-visible spectrometers with microscope and LA-ICPMS in modern gemological laboratories. In the case of diamonds, their colored zones arise from various structural defects incorporated in different growth zones and are studied with FTIR spectrometers with IR microscope and laser photoluminescence spectrometers. Advancement in modern synthetic techniques such as chemical vapor deposition (CVD) has created some problem for identification. Some exploratory experiments in carbon isotope mapping were done on diamonds using SIMS. The most important issue in pearls is to identify one particular pearl being a cultured one or a natural pearl. The price difference can be enormous. Classical way of such identification is done by x-ray radiographs, which clearly show the bead and the nacre. Modern cultured pearl advancement has eliminated the need for an artificial bead, but a small piece of tissue instead. Nowadays, computer x-ray tomography (CT) scanning devices are used to depict the clear image of the interior of a pearl. In the Chinese jade market, filling fissures with epoxy and/or wax are very commonly seen. We are currently exploring Magnetic Resonance Imaging (MRI) technique to map the distribution of artificial resin within a polycrystalline aggregates.

  5. LANDFILL GAS EMISSIONS MODEL (LANDGEM) VERSION 3.02 USER'S GUIDE

    Science.gov (United States)

    The Landfill Gas Emissions Model (LandGEM) is an automated estimation tool with a Microsoft Excel interface that can be used to estimate emission rates for total landfill gas, methane, carbon dioxide, nonmethane organic compounds, and individual air pollutants from municipal soli...

  6. Risk Perception and Social Amplification

    International Nuclear Information System (INIS)

    Smith, R.E.

    2001-01-01

    This paper seeks to consider social amplification as it applies to risk perception. Perceptions of the magnitude of a risk are conditioned by issues such as the degree of uncertainty in probability and consequences, the nature of the consequences and the relative weightings placed on probability and consequences. Risk perceptions are also influenced by factors such as confidence in the operator of an industrial process, trust in the regulator and the perceived fairness of regulatory decision-making. Different people may hold different views about these issues and there may also be difficulties in communication. The paper identifies and discusses self-reinforcing mechanisms, which will be labelled 'lock-in' here. They appear to apply in many situations where social amplification is observed. Historically, the term 'lock-in' has been applied mainly in the technological context but, in this paper, four types of lock-in are identified, namely scientific/technological, economic, social and institutional lock-in. One type of lock-in tends to lead to the next and all are buttressed by people's general acceptance of the familiar, fear of the unknown and resistance to change. The regulator seeks to make decisions which achieve the common good rather than supporting or perpetuating any set of vested interests. In this regard the locked-in positions of stakeholders, whether organisations, interest groups, or individual members of the public, are obstacles and challenges. Existing methods of consultation are unsatisfactory in terms of achieving a proper and productive level of dialogue with stakeholders

  7. Analysis of parental strain DNA fragments existing in GEMs-Fhhh.

    Science.gov (United States)

    Hao, Chun-Bo; Yan, Jun; Qu, Meng-Meng; Wang, Dong; Cheng, Shu-Pei; Gu, Ji-Dong; Qiu, Wan-Fei; Wang, Yin-Yin

    2003-09-01

    There were 6 target DNA fragments of the three parental strains existing in the cell of GEMs (genetically engineered microorganism strain) Fhhh measured in this research by PCR(polymerase chain reaction). The determination showed that GEMs Fhhh contained all the 6 target DNA fragments, mnp1, mnp2, lip1, lip2, FLO1 and 16S rDNA, and had the molecular genetic stability. Meanwhile the PCR production of each parental strain could only had its target DNA fragments and was different from each other. It may illustrate that the technique of the inter-kingdom protoplast fusion for the construction of GEMs Fhhh through the process of intercellular gene recombination could be used as a reliable bioengineering technique to create the specific functional stain for the pollution control.

  8. Study of gain variation as a function of physical parameters of GEM foil

    CERN Document Server

    Das, Supriya

    2015-01-01

    The ALICE experiment at LHC has planned to upgrade the TPC by replacing the MWPC with GEM based detecting elements to restrict the IBF to a tolerable value. However the variation of the gain as a function of physical parameters of industrially produced large size GEM foils is needed to be studied as a part of the QA procedure for the detector. The size of the electron avalanche and consequently the gain for GEM based detectors depend on the electric field distribution inside the holes. Geometry of a hole plays an important role in defining the electric field inside it. In this work we have studied the variation of the gain as a function of the hole diameters using Garfield++ simulation package.

  9. La Gemäldegalerie di Dresda. Evoluzione dal Settecento a fine Ottocento

    Directory of Open Access Journals (Sweden)

    Aloisia Marzotto Caotorta

    2015-12-01

    Full Text Available Since its foundation, the Gemäldegalerie (Old Masters Picture Gallery in Dresden has been considered one of the most magnificent picture galleries in Europe. Not only during the Augustan Age there was a keen interest in the arts, but also a strong understanding of the arts as a means of political power claims. In this context, the Gemäldegalerie was the most representative display of this phenomenon. This article aims to explore the complex role played by the galleries of royal and aristocratic residences in Saxony, concentrating on the Gemäldegalerie between the 18th and 19th centuries as a case study, as well as focusing on its impact on contemporary German literature.

  10. Optical characterization of synthetic faceted gem materials grown from hydrothermal solutions

    Science.gov (United States)

    Lu, Taijin; Shigley, James E.

    1998-10-01

    Various non-destructive optical characterization techniques have been used to characterize and identify synthetic gem materials grown from hydrothermal solutions, to include ruby, sapphire, emerald, amethyst and ametrine (amethyst-citrine), from their natural counterparts. The ability to observe internal features, such as inclusions, dislocations, twins, color bands, and growth zoning in gem materials is strongly dependent on the observation techniques and conditions, since faceted gemstones have many polished surfaces which can reflect and scatter light in various directions which can make observation difficult. However, diagnostic gemological properties of these faceted synthetic gem materials can be obtained by choosing effective optical characterization methods, and by modifying optical instruments. Examples of some of the distinctive features of synthetic amethyst, ametrine, pink quartz, ruby and emerald are presented to illustrate means of optical characterization of gemstones. The ability to observe defects by light scattering techniques is discussed.

  11. Improved model of the Earth's gravitational field: GEM-T1

    International Nuclear Information System (INIS)

    Marsh, J.G.; Lerch, F.J.; Christodoulidis, D.C.

    1987-07-01

    Goddard Earth Model T1 (GEM-T1), which was developed from an analysis of direct satellite tracking observations, is the first in a new series of such models. GEM-T1 is complete to degree and order 36. It was developed using consistent reference parameters and extensive earth and ocean tidal models. It was simultaneously solved for gravitational and tidal terms, earth orientation parameters, and the orbital parameters of 580 individual satellite arcs. The solution used only satellite tracking data acquired on 17 different satellites and is predominantly based upon the precise laser data taken by third generation systems. In all, 800,000 observations were used. A major improvement in field accuracy was obtained. For marine geodetic applications, long wavelength geoidal modeling is twice as good as in earlier satellite-only GEM models. Orbit determination accuracy has also been substantially advanced over a wide range of satellites that have been tested

  12. GEM System: automatic prototyping of cell-wide metabolic pathway models from genomes

    Directory of Open Access Journals (Sweden)

    Nakayama Yoichi

    2006-03-01

    Full Text Available Abstract Background Successful realization of a "systems biology" approach to analyzing cells is a grand challenge for our understanding of life. However, current modeling approaches to cell simulation are labor-intensive, manual affairs, and therefore constitute a major bottleneck in the evolution of computational cell biology. Results We developed the Genome-based Modeling (GEM System for the purpose of automatically prototyping simulation models of cell-wide metabolic pathways from genome sequences and other public biological information. Models generated by the GEM System include an entire Escherichia coli metabolism model comprising 968 reactions of 1195 metabolites, achieving 100% coverage when compared with the KEGG database, 92.38% with the EcoCyc database, and 95.06% with iJR904 genome-scale model. Conclusion The GEM System prototypes qualitative models to reduce the labor-intensive tasks required for systems biology research. Models of over 90 bacterial genomes are available at our web site.

  13. The game-based learning evaluation model (GEM): measuring the effectiveness of serious games using a standardised method

    NARCIS (Netherlands)

    Oprins, E.A.P.B.; Visschedijk, G.C.; Bakhuys Roozeboom, M.M.C.; Dankbaar, M.; Trooster, W.; Schuit, S.C.E.

    2015-01-01

    This article describes the background, design, and practical application of the game-based evaluation model (GEM). The aim of this evaluation model is to measure the effectiveness of serious games in a practical way. GEM contains the methodology and indicators to be measured in validation research.

  14. Advances in Trace Element “Fingerprinting” of Gem Corundum, Ruby and Sapphire, Mogok Area, Myanmar

    Directory of Open Access Journals (Sweden)

    F. Lin Sutherland

    2014-12-01

    Full Text Available Mogok gem corundum samples from twelve localities were analyzed for trace element signatures (LA-ICP-MS method and oxygen isotope values (δ18O, by laser fluorination. The study augmented earlier findings on Mogok gem suites that suggested the Mogok tract forms a high vanadium gem corundum area and also identified rare alluvial ruby and sapphire grains characterised by unusually high silicon, calcium and gallium, presence of noticeable boron, tin and niobium and very low iron, titanium and magnesium contents. Oxygen isotope values (δ18O for the ruby and high Si-Ca-Ga corundum (20‰–25‰ and for sapphire (10‰–20‰ indicate typical crustal values, with values >20‰ being typical of carbonate genesis. The high Si-Ca-Ga ruby has high chromium (up to 3.2 wt % Cr and gallium (up to 0. 08 wt % Ga compared to most Mogok ruby (<2 wt % Cr; <0.02 wt % Ga. In trace element ratio plots the Si-Ca-Ga-rich corundum falls into separate fields from the typical Mogok metamorphic fields. The high Ga/Mg ratios (46–521 lie well within the magmatic range (>6, and with other features suggest a potential skarn-like, carbonate-related genesis with a high degree of magmatic fluid input The overall trace element results widen the range of different signatures identified within Mogok gem corundum suites and indicate complex genesis. The expanded geochemical platform, related to a variety of metamorphic, metasomatic and magmatic sources, now provides a wider base for geographic typing of Mogok gem corundum suites. It allows more detailed comparisons with suites from other deposits and will assist identification of Mogok gem corundum sources used in jewelry.

  15. Financial recognition of material misstatement risks of listed companies on GEM

    Directory of Open Access Journals (Sweden)

    Jie Ming

    2017-11-01

    Full Text Available Listed companies on GEM are characterized by strong innovation, great growth ability, high risks and high yields. Starting from these characteristics, this paper carries out analysis by using the financial indicators that are effective to recognize the material misstatement risks and easy to be acquired, and combines with the sample data with high material misstatement risks on GEM in 2012 to 2014 to test the significance of spss difference, and finds that the material misstatement company and the normal company have significant difference in the profitability, solvency, growth ability and cash flow.

  16. Study of gem materials by neutron irradiation: characterization of impurities and color centers

    International Nuclear Information System (INIS)

    Leal, Alexandre S.; Menezes, Maria A.B.C.; Brito, Walter de; D'Urco, Ana F.A.; Felix, Marcia C.; Krambrock, Klaus; Ferreira, Ana F.

    2005-01-01

    Since one-century laboratory irradiation techniques are applied to the color enhancement of gem minerals. Its actual status and applications are discussed. Many different colors in a variety of gem minerals can be produced by gamma, electron and neutron irradiation combined with thermal treatments, however, many color centers and coloration processes are not known in detail. In this work we present examples of neutron irradiation applied to colorless topaz, spodumene and diamond. Topaz and diamond turned blue, spodumene orange. All color centers produced by neutron irradiation are stable to elevated temperatures and can be considered as color enhancing processes. (author)

  17. Proceso de creación de Almus-Gemüse: pates de legumbres

    OpenAIRE

    MATA CAGIGAO, ELENA

    2016-01-01

    [ES] Almus-Gemüse es proyecto de diseño de producto enmarcado en un proyecto empresarial presentado al certamen nacional Ecotrophelia 2016. Con él los alumnos implicados consiguieron el tercer puesto. Almus-Gemüse está enfocado a la elaboración de productos con textura de paté, con altramuces como ingrediente base. El proyecto propone una gamma de productos sabores del mundo creados con diferentes especias e ingredientes. Para el desarrollo de este proyecto se emplearon las cinco pa...

  18. A novel High-Voltage System for a triple GEM detector

    CERN Document Server

    Corradi, Giovanni; Tagnani, Diego; 10.1016/j.nima.2006.10.166

    2007-01-01

    A novel High-Voltage System for a triple GEM detector has been designed and realized in Frascati within the LHCb muon detector framework. The system is built with seven floating power supply, with a maximum of 1200 V each, and controlled via CANbus, for voltage settings and monitoring. Several HV modules can be installed in a nano-ammeter mainframe already developed in Frascati, realizing a HV crate able to supply up to 24 triple GEM chambers with a 1 nA resolution monitoring system.

  19. Multiscale image contrast amplification (MUSICA)

    Science.gov (United States)

    Vuylsteke, Pieter; Schoeters, Emile P.

    1994-05-01

    This article presents a novel approach to the problem of detail contrast enhancement, based on multiresolution representation of the original image. The image is decomposed into a weighted sum of smooth, localized, 2D basis functions at multiple scales. Each transform coefficient represents the amount of local detail at some specific scale and at a specific position in the image. Detail contrast is enhanced by non-linear amplification of the transform coefficients. An inverse transform is then applied to the modified coefficients. This yields a uniformly contrast- enhanced image without artefacts. The MUSICA-algorithm is being applied routinely to computed radiography images of chest, skull, spine, shoulder, pelvis, extremities, and abdomen examinations, with excellent acceptance. It is useful for a wide range of applications in the medical, graphical, and industrial area.

  20. Risk Perception and Social Amplification

    Energy Technology Data Exchange (ETDEWEB)

    Smith, R.E. [Environment Agency (United Kingdom)

    2001-07-01

    This paper seeks to consider social amplification as it applies to risk perception. Perceptions of the magnitude of a risk are conditioned by issues such as the degree of uncertainty in probability and consequences, the nature of the consequences and the relative weightings placed on probability and consequences. Risk perceptions are also influenced by factors such as confidence in the operator of an industrial process, trust in the regulator and the perceived fairness of regulatory decision-making. Different people may hold different views about these issues and there may also be difficulties in communication. The paper identifies and discusses self-reinforcing mechanisms, which will be labelled 'lock-in' here. They appear to apply in many situations where social amplification is observed. Historically, the term 'lock-in' has been applied mainly in the technological context but, in this paper, four types of lock-in are identified, namely scientific/technological, economic, social and institutional lock-in. One type of lock-in tends to lead to the next and all are buttressed by people's general acceptance of the familiar, fear of the unknown and resistance to change. The regulator seeks to make decisions which achieve the common good rather than supporting or perpetuating any set of vested interests. In this regard the locked-in positions of stakeholders, whether organisations, interest groups, or individual members of the public, are obstacles and challenges. Existing methods of consultation are unsatisfactory in terms of achieving a proper and productive level of dialogue with stakeholders.

  1. The GEM code. A simulation program for the evaporation and the fission process of an excited nucleus

    Energy Technology Data Exchange (ETDEWEB)

    Furihata, Shiori [Mitsubishi Research Institute Inc., Tokyo (Japan); Niita, Koji [Research Organization for Information Science and Technology, Tokai, Ibaraki (Japan); Meigo, Shin-ichiro; Ikeda, Yujiro; Maekawa, Fujio [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2001-03-01

    The GEM code is a simulation program which describes the de-excitation process of an excited nucleus, which is based on the Generalized Evaporation Model and the Atchison fission model. It has been shown that the combination of the Bertini intranuclear cascade model and GEM accurately predicts the cross sections of light fragments, such as Be produced from the proton-induced reactions. It has also been shown that the use of the reevaluated parameters in the Atchison model improves predictions of cross sections of fission fragments produced from the proton-induced reaction on Au. In this report, we present details and the usage of the GEM code. Furthermore, the results of benchmark calculations are shown by using the combination of the Bertini intranuclear cascade model and the GEM code (INC/GEM). Neutron spectra and isotope production cross sections from the reactions on various targets irradiated by protons are calculated with INC/GEM. Those results are compared with experimental data as well as the calculation results with LAHET. INC/GEM reproduces the experiments of double differential neutron emissions from the reaction on Al and Pb. The isotopic distributions for He, Li, and Be produced from the reaction on Ag are in good agreement with experimental data within 50%, although INC/GEM underestimates those of heavier nuclei than O. It is also shown that the predictions with INC/GEM for isotope production of light fragments, such as Li and Be, are better than those calculation with LAHET, particularly for heavy target. INC/GEM also gives better estimates of the cross sections of fission products than LAHET. (author)

  2. OpenGeoSys-GEMS: Hybrid parallelization of a reactive transport code with MPI and threads

    Science.gov (United States)

    Kosakowski, G.; Kulik, D. A.; Shao, H.

    2012-04-01

    OpenGeoSys-GEMS is a generic purpose reactive transport code based on the operator splitting approach. The code couples the Finite-Element groundwater flow and multi-species transport modules of the OpenGeoSys (OGS) project (http://www.ufz.de/index.php?en=18345) with the GEM-Selektor research package to model thermodynamic equilibrium of aquatic (geo)chemical systems utilizing the Gibbs Energy Minimization approach (http://gems.web.psi.ch/). The combination of OGS and the GEM-Selektor kernel (GEMS3K) is highly flexible due to the object-oriented modular code structures and the well defined (memory based) data exchange modules. Like other reactive transport codes, the practical applicability of OGS-GEMS is often hampered by the long calculation time and large memory requirements. • For realistic geochemical systems which might include dozens of mineral phases and several (non-ideal) solid solutions the time needed to solve the chemical system with GEMS3K may increase exceptionally. • The codes are coupled in a sequential non-iterative loop. In order to keep the accuracy, the time step size is restricted. In combination with a fine spatial discretization the time step size may become very small which increases calculation times drastically even for small 1D problems. • The current version of OGS is not optimized for memory use and the MPI version of OGS does not distribute data between nodes. Even for moderately small 2D problems the number of MPI processes that fit into memory of up-to-date workstations or HPC hardware is limited. One strategy to overcome the above mentioned restrictions of OGS-GEMS is to parallelize the coupled code. For OGS a parallelized version already exists. It is based on a domain decomposition method implemented with MPI and provides a parallel solver for fluid and mass transport processes. In the coupled code, after solving fluid flow and solute transport, geochemical calculations are done in form of a central loop over all finite

  3. Large Gas Electron Multiplier Trackers for Super Bigbite Spectrometer at Jefferson lab Hall A

    Science.gov (United States)

    Saenboonruang, K.; Gnanvo, K.; Liyanage, N.; Nelyubin, V.; Sacher, S.; Cisbani, E.; Musico, P.; Wojtsekhowski, B.

    2013-04-01

    The 12 GeV upgrade at Jefferson Lab (JLAB) makes many exciting nuclear experiments possible. These experiments also require new high performance instrumentation. The Super Bigbite Spectrometer (SBS) was proposed to perform a series of high precision nucleon form factor experiments at large momentum transfer. The SBS will be capable of operating at a very high luminosity and provide a large solid angle acceptance of 76 msr. SBS will be equipped with a double focal plane polarimeter. Thus, SBS will have three large trackers made of Gas Electron Multiplier (GEM) chambers. The first, second, and third trackers will consist of six, four, and four tracking layers respectively. When completed in 2017, the SBS GEM trackers will form one of the largest sets of GEM chambers in the world. The GEM trackers allow the SBS to operate under high background rates over 500 kHz/cm^2, while providing an excellent spatial resolution of 70 μm. The first tracker will be constructed at the Istituto Nazionale di Fisica Nucleare in Italy, while the second and third trackers will be built at the University of Virginia. In 2012, the first UVa SBS GEM chamber prototype was successfully constructed and tested. The GEM chamber construction details and test results will be presented in this talk.

  4. The design of the electronic system on neutron beam monitor based on GEM

    International Nuclear Information System (INIS)

    Zuo Min; Zhuang Bao'an; Zhao Yubin; Chen Shaojia; Wang Na; Zhang Hongyu; Zhao Jingwei

    2012-01-01

    The Neutron Beam Monitor - a GEM based system used to monitor the neutron beams in real time - is introduced. The electronic parts are described in details, including the principles of the circuit, the system structure, the design of the Daughterboard and the logic and algorithm of the FPGA on the Monitor board. The test results are also given out in the final. (authors)

  5. 16 CFR 23.25 - Misuse of the word “gem.”

    Science.gov (United States)

    2010-01-01

    ... other industry product that does not possess the beauty, symmetry, rarity, and value necessary for... JEWELRY, PRECIOUS METALS, AND PEWTER INDUSTRIES § 23.25 Misuse of the word “gem.” (a) It is unfair or... industry product unless the product meets the requirements of paragraph (a) of this section and unless such...

  6. Physics motivations and expected performance of the CMS muon system upgrade with triple-GEM detectors

    CERN Document Server

    Venditti, Rosamaria; Abbrescia, Marcello; Aleksandrov, Andrey B; Benussi, Luigi; Beni, Noemi; Bianco, Stefano; Calabria, Cesare; Caponero, Michele; Hernandez, Alfredo Martin Castaneda; Cavallo, Francesca; Colafranceschi, Stefano; Lentdecker, Gilles De; Oliveira, R; Guiducci, Luigi; Hoepfner, Kerstin; Iaydjiev, P S; Korytov, Andrey; Krutelyov, Slava; Kumar, A; Lee, Jason; Litov, L; Loddo, F; Maggi, M; Marchioro, Alessandro; Mitselmakher, Guenakh; Mohanty, Ajit Kumar; Molnar, J; Naimuddin, Md; Nuzzo, S; Pant, Lalit; Paolucci, Pierluigi; Pavlov, Borislav; Piccolo, Davide; Postema, Hans; Raffaella, Radogna; Ranieri, A; Riccardi, C; Rodozov, Mircho; Safonov, Alexei; Saviano, Giovanna; Sharma, Archana; Tytgat, Michael; Vitulo, Paolo; Colaleo, Anna; Caputo, Claudio; Errico, Filippo; Dildick, Sven; Vai, Ilaria; Magnani, Alice; Verwilligen, Piet; Altieri, Palma; Aspell, Paul; Giacomelli, Paolo; Braibant, Sylvie; Buontempo, S; Kamon, Teruki; Tatarinov, A; Celik, Ali; Gilmore, Jason; Flanagan, Will; Khotilovich, Vadim; Czellar, S; Fenyvesi, A; Jozsef Molnar@Cern Ch, Jozsef; Barria, P; Korntheuer, Michael; Lenzi, T; Maerschalk, T; Verhagen, E; Yang, Yifan; Yonamine, R; Zenoni, F; Merlin, J; Dorney, B; Garcia, A Conde; Dabrowski, M; Marinov, A; Oliveri, E; Baranac, A Puig; Ropelewski, Leszek; Bos, J; Bally, S; Stenis, M Van; Ferry, S; Rodrigues, A; Robertis, G De; Christiansen, J; Hohlmann, M; Bhopatkar, V; Mohapatra, A; Zhang, A; Hauser, J; Tuuva, Tuure; Talvitie, J; Passeggio, G; Cassese, F; Banerjee, S; Majumdar, N; Mukhopadhyay, Supratik; Roychowdhur, S; Salva, S; Zaganidis, N; Cimmino, A; Cauwenbergh, S; Bouhali, O; Akl, M Abi; Sturdy, J; Karchin, P; Gutierrez, A; Hadjiiska, R; Aleksandrov, Aleksandar; Rashevski, G; Rodozov, M; Shopova, M; Sultanov, G; Acosta, D; Barashko, V; Furic, I; Madorsky, A; Korytov, A; Mitselmakher, G; Raffone, G; Radi, A; Assran, Y; Aboamer, O; Ahmad, A; Ahmed, W; Awan, I; Hoorani, H; Muhammad, S; Sharma, R; Geonmo, R; Ryu, M S; Park, I; Jeng, Y C; Choi, M; Golovtsov, V; Volkov, S; Vorobyev, A; Choi, S; Guilloux, F; Philipps, B

    2015-01-01

    For the LHC High Luminosity phase (HL-LHC) the CMS GEM Collaboration is planning to in- stall new large size triple-GEM detectors in the forward region of the muon system (1.5< j h |<2.2) of the CMS detector. The muon reconstruction with triple-GEM chambers information included have been successfully integrated in the official CMS software, allowing physics studies to be carried out. The new sub-detector will be able to cope the extreme particle rates expected in this region along with a high spatial resolution. The resulting benefit in terms of triggering and tracking capabilities has been studied: the expected improvement in the performance of the muon identification and track reconstruction as well as the expected improvement coming from the low- ering of the muon p T trigger tresholds will be presented. The contribution will review the status of the CMS upgrade project with the usage of GEM detector, discussing the trigger, the muon reconstruction performance and the impact on the physics analyses.

  7. Promoting microbiology education through the iGEM synthetic biology competition.

    Science.gov (United States)

    Kelwick, Richard; Bowater, Laura; Yeoman, Kay H; Bowater, Richard P

    2015-08-01

    Synthetic biology has developed rapidly in the 21st century. It covers a range of scientific disciplines that incorporate principles from engineering to take advantage of and improve biological systems, often applied to specific problems. Methods important in this subject area include the systematic design and testing of biological systems and, here, we describe how synthetic biology projects frequently develop microbiology skills and education. Synthetic biology research has huge potential in biotechnology and medicine, which brings important ethical and moral issues to address, offering learning opportunities about the wider impact of microbiological research. Synthetic biology projects have developed into wide-ranging training and educational experiences through iGEM, the International Genetically Engineered Machines competition. Elements of the competition are judged against specific criteria and teams can win medals and prizes across several categories. Collaboration is an important element of iGEM, and all DNA constructs synthesized by iGEM teams are made available to all researchers through the Registry for Standard Biological Parts. An overview of microbiological developments in the iGEM competition is provided. This review is targeted at educators that focus on microbiology and synthetic biology, but will also be of value to undergraduate and postgraduate students with an interest in this exciting subject area. © FEMS 2015. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  8. [Occupational health status of migrant female workers of artificial gem manufacturing cottages in Guangxi].

    Science.gov (United States)

    Wang, Chao-Ying; Wang, Fang; Wang, Hui-Ming; Chen, Run-Jie; Yu, Wen-Lan

    2011-09-01

    To investigate occupational health status in migrant female workers in artificial gem cottages in Guangxi and to provide reference evidence for drawing up countermeasures to protect migrant female workers from occupational hazards. Two thousands and ninety five migrant female workers in artificial gem manufacturing cottages in Wuzhou City, Guangxi Province, were randomly recruited to participate in the investigation. The standardized occupational health questionnaires were used to collect the information of demographic characteristics, occupational exposure and medical symptoms by interviewing with persons. Artificial gem manufacturing cottages in Wuzhou were mainly composed of family-workshops. There were only simple and crude hygienic facilities. Major occupational hazards included dusts, noise, vibration, hydrofluoric acid, and light stimulation. The mean age of workers was 30. Mean exposure duration was 5 years. There was no occupational health monitoring records for these workers in the past years. Major symptoms included back pain, eye discomfort, and headache. The incidence of discomfort symptoms increased with age. Occupational health protection and monitoring in artificial gem manufacturing cottage, in Guangxi have not been performed. More effective occupational health education and administration need to implement in family-type handicraft manufacturing.

  9. The new cylindrical GEM inner tracker of BESIII arXiv

    CERN Document Server

    Lavezzi, L.; Amoroso, A.; Ferroli, R. Baldini; Bertani, M.; Bettoni, D.; Bianchi, F.; Calcaterra, A.; Canale, N.; Capodiferro, M.; Carassiti, V.; Cerioni, S.; Chai, JY.; Chiozzi, S.; Cibinetto, G.; Cossio, F.; Cotta Ramusino, A.; De Mori, F.; Destefanis, M.; Dong, J.; Evangelisti, F.; Farinelli, R.; Fava, L.; Felici, G.; Fioravanti, E.; Garzia, I.; Gatta, M.; Greco, M.; Leng, CY.; Li, H.; Maggiora, M.; Malaguti, R.; Marcello, S.; Melchiorri, M.; Mezzadri, G.; Mignone, M.; Morello, G.; Pacetti, S.; Patteri, P.; Pellegrino, J.; Pelosi, A.; Rivetti, A.; Rolo, M.D.; Savrie', M.; Scodeggio, M.; Soldani, E.; Sosio, S.; Spataro, S.; Tskhadadze, E.; Verma, S.; Wheadon, R.; Yan, L.

    The Cylindrical GEM-Inner Tracker (CGEM-IT) is the upgrade of the internal tracking system of the BESIII experiment. It consists of three layers of cylindrically-shaped triple GEMs, with important innovations with respect to the existing GEM detectors, in order to achieve the best performance with the lowest material budget. It will be the first cylindrical GEM running with analog readout inside a 1T magnetic field. The simultaneous measurement of both the deposited charge and the signal time will permit to use a combination of two algorithms to evaluate the spatial position of the charged tracks inside the CGEM-IT: the charge centroid and the micro time projection chamber modes. They are complementary and can cope with the asymmetry of the electron avalanche when running in magnetic field and with non-orthogonal incident tracks. To evaluate the behavior under different working settings, both planar chambers and the first cylindrical prototype have been tested during various test beams at CERN with 150 GeV/c ...

  10. Experiential Engineering through iGEM--An Undergraduate Summer Competition in Synthetic Biology

    Science.gov (United States)

    Mitchell, Rudolph; Dori, Yehudit Judy; Kuldell, Natalie H.

    2011-01-01

    Unlike students in other engineering disciplines, undergraduates in biological engineering typically have limited opportunity to develop design competencies, and even fewer chances to implement their designed projects. The international Genetically Engineered Machines (iGEM) competition is a student Synthetic Biology competition that, in 2009,…

  11. The gem collection of the Rijksmuseum van Geologie en Mineralogie of Leiden The Peridots

    NARCIS (Netherlands)

    Zwaan, P.C.

    1957-01-01

    The peridots in the gem collection of our Museum were acquired a long time ago (part of them were from the collection of King William I of the Netherlands). We should be sceptical about data on the origin of this material. Firstly we do not generally know whether the stones were bought or received

  12. MeerLICHT and BlackGEM: custom-built telescopes to detect faint optical transients

    Science.gov (United States)

    Bloemen, Steven; Groot, Paul; Woudt, Patrick; Klein Wolt, Marc; McBride, Vanessa; Nelemans, Gijs; Körding, Elmar; Pretorius, Margaretha L.; Roelfsema, Ronald; Bettonvil, Felix; Balster, Harry; Bakker, Roy; Dolron, Peter; van Elteren, Arjen; Elswijk, Eddy; Engels, Arno; Fender, Rob; Fokker, Marc; de Haan, Menno; Hagoort, Klaas; de Hoog, Jasper; ter Horst, Rik; van der Kevie, Giel; Kozłowski, Stanisław; Kragt, Jan; Lech, Grzegorz; Le Poole, Rudolf; Lesman, Dirk; Morren, Johan; Navarro, Ramon; Paalberends, Willem-Jelle; Paterson, Kerry; Pawłaszek, Rafal; Pessemier, Wim; Raskin, Gert; Rutten, Harrie; Scheers, Bart; Schuil, Menno; Sybilski, Piotr W.

    2016-07-01

    We present the MeerLICHT and BlackGEM telescopes, which are wide-field optical telescopes that are currently being built to study transient phenomena, gravitational wave counterparts and variable stars. The telescopes have 65 cm primary mirrors and a 2.7 square degree field-of-view. The MeerLICHT and BlackGEM projects have different science goals, but will use identical telescopes. The first telescope, MeerLICHT, will be commissioned at Sutherland (South Africa) in the first quarter of 2017. It will co-point with MeerKAT to collect optical data commensurate with the radio observations. After careful analysis of MeerLICHT's performance, three telescopes of the same type will be commissioned in La Silla (Chile) in 2018 to form phase I of the BlackGEM array. BlackGEM aims at detecting and characterizing optical counterparts of gravitational wave events detected by Advanced LIGO and Virgo. In this contribution we present an overview of the science goals, the design and the status of the two projects.

  13. Gems [Guardian Environmental Monitoring System] keeps a continuous eye on gamma-ray emissions

    International Nuclear Information System (INIS)

    Gould, J.L.

    1986-01-01

    To enable electricity utilities to demonstrate the very low release rates of radiation emitters from nuclear power stations into the environment, Gems (Guardian Environmental Monitoring System) has been developed. The units have been installed as emergency plume monitors round the perimeter of several British power stations and can be connected to windspeed and direction instrumentation to provide on-line activity release data. (UK)

  14. The GTPase Gem and its partner Kif9 are required for chromosome alignment, spindle length control, and mitotic progression.

    Science.gov (United States)

    Andrieu, Guillaume; Quaranta, Muriel; Leprince, Corinne; Hatzoglou, Anastassia

    2012-12-01

    Within the Ras superfamily, Gem is a small GTP-binding protein that plays a role in regulating Ca(2+) channels and cytoskeletal remodeling in interphase cells. Here, we report for the first time that Gem is a spindle-associated protein and is required for proper mitotic progression. Functionally, loss of Gem leads to misaligned chromosomes and prometaphase delay. On the basis of different experimental approaches, we demonstrate that loss of Gem by RNA interference induces spindle elongation, while its enforced expression results in spindle shortening. The spindle length phenotype is generated through deregulation of spindle dynamics on Gem depletion and requires the expression of its downstream effector, the kinesin Kif9. Loss of Kif9 induces spindle abnormalities similar to those observed when Gem expression is repressed by siRNA. We further identify Kif9 as a new regulator of spindle dynamics. Kif9 depletion increases the steady-state levels of spindle α-tubulin by increasing the rate of microtubule polymerization. Overall, this study demonstrates a novel mechanism by which Gem contributes to the mitotic progression by maintaining correct spindle length through the kinesin Kif9.

  15. A free-volume modification of GEM-QC to correlate VLE and LLE in polymer solutions

    International Nuclear Information System (INIS)

    Radfarnia, H.R.; Taghikhani, V.; Ghotbi, C.; Khoshkbarchi, M.K.

    2004-01-01

    The generalized quasi-chemical (GEM-QC) model proposed by Wang and Vera is modified to correlate better the phase equilibrium and to overcome the shortcoming of the original model to predict the lower critical solution temperature (LCST) of binary polymer solutions. This shortcoming is mainly because the GEM-QC model does not consider the effect of free-volume, which is important in systems containing molecules with large size differences. The proposed modification is based on replacing the combinatorial term of the GEM-QC model by a term proposed by Kontogerogis et al., which includes the effect of the free-volume. The main advantage of the free volume generalized quasi-chemical (GEM-QC-FV) model over the original GEM-QC is its ability to predict the phase behaviour of binary polymer solutions with LCST behaviour. In addition, the free volume UNIQUAC (UNIQUAC-FV) model is used to correlate VLE and LLE experimental data for binary polymer solutions. The comparison of the results obtained from the GEM-QC-FV model and the UNIQUAC-FV model shows the superiority of the GEM-QC-FV model in correlating the VLE and LLE experimental data for binary polymer solutions

  16. ISC-GEM: Global Instrumental Earthquake Catalogue (1900-2009) I. Location and Seismicity Patterns

    Science.gov (United States)

    Bondar, I.; Engdahl, E. R.; Villasenor, A.; Storchak, D. A.

    2012-12-01

    We present the final results of a two-year project sponsored by the GEM (Global Earthquake Model) Foundation. The ISC-GEM global catalogue consists of some 19 thousand instrumentally recorded, moderate to large earthquakes, spanning 110 years of seismicity. We relocated all events in the catalogue using a two-tier approach. The EHB location methodology (Engdahl et al., 1998) was applied first to obtain improved hypocentres with special focus on the depth determination. The locations were further refined in the next step by fixing the depths to those from the EHB analysis and applying the new ISC location algorithm (Bondár and Storchak, 2011) that reduces location bias by accounting for correlated travel-time prediction error structure. To facilitate the relocation effort, some 900,000 seismic P and S wave arrival-time data were added to the ISC database for the period between 1904 and 1963, either from original station bulletins in the ISC archive or by digitizing the scanned images of the ISS bulletin (Villaseñor and Engdahl, 2005; 2007). Although no substantial amount of new phase data were acquired for the modern period (1964-2009), the number of phases used in the location has still increased by 3 million, owing to fact that both the EHB and ISC locators use all ak135 (Kennett et al., 1995) phases in the location. We show that the relocation effort yielded substantially improved locations, especially in the first half of the 20th century; we demonstrate significant improvements in focal depth estimates in subduction zones and other seismically active regions; and we show that the ISC-GEM catalogue provides an improved view of 110 years of global seismicity of the Earth. The ISC-GEM Global Instrumental Earthquake Catalogue represents the final product of one of the ten global components in the GEM program, and will be made available to researchers at the ISC (www.isc.ac.uk) website.

  17. Amplification of chirality in liquid crystals

    NARCIS (Netherlands)

    Eelkema, Rienk; Feringa, Ben L.

    2006-01-01

    The amplification of molecular chirality by liquid crystalline systems is widely applied in investigations towards enantioselective solvent - solute interactions, chiral supramolecular assemblies, smart materials, and the development of liquid crystal displays. Here we present an overview of recent

  18. Privacy amplification for quantum key distribution

    International Nuclear Information System (INIS)

    Watanabe, Yodai

    2007-01-01

    This paper examines classical privacy amplification using a universal family of hash functions. In quantum key distribution, the adversary's measurement can wait until the choice of hash functions is announced, and so the adversary's information may depend on the choice. Therefore the existing result on classical privacy amplification, which assumes the independence of the choice from the other random variables, is not applicable to this case. This paper provides a security proof of privacy amplification which is valid even when the adversary's information may depend on the choice of hash functions. The compression rate of the proposed privacy amplification can be taken to be the same as that of the existing one with an exponentially small loss in secrecy of a final key. (fast track communication)

  19. Rolling circle amplification of metazoan mitochondrialgenomes

    Energy Technology Data Exchange (ETDEWEB)

    Simison, W. Brian; Lindberg, D.R.; Boore, J.L.

    2005-07-31

    Here we report the successful use of rolling circle amplification (RCA) for the amplification of complete metazoan mt genomes to make a product that is amenable to high-throughput genome sequencing techniques. The benefits of RCA over PCR are many and with further development and refinement of RCA, the sequencing of organellar genomics will require far less time and effort than current long PCR approaches.

  20. Four-photon parametric amplification in semiconductors

    International Nuclear Information System (INIS)

    Jain, M.; Gersten, J.; Tzoar, N.

    1975-01-01

    A theoretical study of four-photon parametric amplification in narrow-band-gap semiconductors is made. It is shown that phase matching is achievable in a linear geometry if a magnetic field is employed. Furthermore, a substantial cyclotron resonance enhancement occurs in the presence of a magnetic field. We calculate the growth rates and threshold fields associated with the parametric amplification and conclude that an efficient laser may be designed based on this process

  1. Design of a New Type of Compact Chemical Heater for Isothermal Nucleic Acid Amplification.

    Science.gov (United States)

    Shah, Kamal G; Guelig, Dylan; Diesburg, Steven; Buser, Joshua; Burton, Robert; LaBarre, Paul; Richards-Kortum, Rebecca; Weigl, Bernhard

    2015-01-01

    Previous chemical heater designs for isothermal nucleic acid amplification have been based on solid-liquid phase transition, but using this approach, developers have identified design challenges en route to developing a low-cost, disposable device. Here, we demonstrate the feasibility of a new heater configuration suitable for isothermal amplification in which one reactant of an exothermic reaction is a liquid-gas phase-change material, thereby eliminating the need for a separate phase-change compartment. This design offers potentially enhanced performance and energy density compared to other chemical and electric heaters.

  2. Study of the dE/dx resolution of a GEM Readout Chamber prototype for the upgrade of the ALICE TPC

    Science.gov (United States)

    Mathis, Andreas

    2018-02-01

    The ALICE Collaboration is planning a major upgrade of its central barrel detectors to be able to cope with the increased LHC luminosity beyond 2020. For the TPC, this implies a replacement of the currently used gated MWPCs (Multi-Wire Proportional Chamber) by GEM (Gas Electron Multiplier) based readout chambers. In order to prove, that the present particle identification capabilities via measurement of the specific energy loss are retained after the upgrade, a prototype of the ALICE IROC (Inner Readout Chamber) has been evaluated in a test beam campaign at the CERN PS. The dE/dx resolution of the prototype has been proven to be fully compatible with the current MWPCs.

  3. Recalibration of the HBWR gamma aspectrometer GEM-10175-P

    International Nuclear Information System (INIS)

    Wright, J.; Blair, P.; Turnbull, T.; Fure, K.

    2005-09-01

    The gas flow system and gamma spectrometer continue to provide valuable fission gas release data. Measurements are made on a wide range of Xe and Kr isotopes and using a more complicated procedure it is possible to measure iodine isotopes directly. Routine measurements are currently made on two gas flow rigs loaded in the Halden reactor; the UO 2 and MOX comparison test IFA-633, and the high burnup disk irradiation test IFA-655. Prior to these rigs fission gas release data was obtained principally from IFA-504 and IFA-558. A gamma spectrometer was installed at the reactor to allow the first FIA-430 gamma spectra to be obtained in January 1980. This spectrometer continued in operation until a new spectrometer was installed towards the end of 1997 and began operation in January 1998. This second spectrometer is still in regular use. Both gamma spectrometers required calibration before the gamma spectra obtained could be analysed. This calibration involves calculating the detector efficiency, i.e. the fraction of emitted gamma rays which are detected, over the range of gamma rays to be measured. The calibration of the original and replacement spectrometer is documented in [1] and [2] respectively. This report documents a more recent recalibration of the current spectrometer. This recalibration was deemed necessary for two reasons; firstly since no recalibrations had been performed since the spectrometer was installed in 1997 another calibration, across the entire energy range, was now overdue and secondly a more accurate value of the spectrometer efficiency in the low energy region was needed to obtain reliable 133 Xe measurements. As explained in more detail in the report reliable 133 Xe data is needed to obtain 133 I data using a fractal scaling method. (Author)

  4. Development of a tracker based on GEM optically readout

    CERN Document Server

    Torchia, Natalia

    The high-resolution tracking of low energy release particles had a remarkable development in recent years and will give a crucial contribution in different sectors, from medical applications to those in dark matter search. Thanks to their characteristics (high space and time resolution, low material budget, large volumes, low costs) the gas detectors have shown to be ideal candidates for this type of trackers. In particular, a very promising technique regards the optical reading of the light produced by the de-excitation of gas molecules during the processes of electron multiplication. This type of detector has been made possible thanks to the great progresses achieved in last years in the performance in micro pattern gas detector and in the evolution of the CMOS technology which led to the production of sensors able of offering high sensitivity and granularity combined with a very low noise level. In this thesis I studied the performance of a two prototypes where the light is produced through the multiplicat...

  5. Heat induces gene amplification in cancer cells

    International Nuclear Information System (INIS)

    Yan, Bin; Ouyang, Ruoyun; Huang, Chenghui; Liu, Franklin; Neill, Daniel; Li, Chuanyuan; Dewhirst, Mark

    2012-01-01

    Highlights: ► This study discovered that heat exposure (hyperthermia) results in gene amplification in cancer cells. ► Hyperthermia induces DNA double strand breaks. ► DNA double strand breaks are considered to be required for the initiation of gene amplification. ► The underlying mechanism of heat-induced gene amplification is generation of DNA double strand breaks. -- Abstract: Background: Hyperthermia plays an important role in cancer therapy. However, as with radiation, it can cause DNA damage and therefore genetic instability. We studied whether hyperthermia can induce gene amplification in cancer cells and explored potential underlying molecular mechanisms. Materials and methods: (1) Hyperthermia: HCT116 colon cancer cells received water-submerged heating treatment at 42 or 44 °C for 30 min; (2) gene amplification assay using N-(phosphoacetyl)-L-aspartate (PALA) selection of cabamyl-P-synthetase, aspartate transcarbarmylase, dihydro-orotase (cad) gene amplified cells; (3) southern blotting for confirmation of increased cad gene copies in PALA-resistant cells; (4) γH2AX immunostaining to detect γH2AX foci as an indication for DNA double strand breaks. Results: (1) Heat exposure at 42 or 44 °C for 30 min induces gene amplification. The frequency of cad gene amplification increased by 2.8 and 6.5 folds respectively; (2) heat exposure at both 42 and 44 °C for 30 min induces DNA double strand breaks in HCT116 cells as shown by γH2AX immunostaining. Conclusion: This study shows that heat exposure can induce gene amplification in cancer cells, likely through the generation of DNA double strand breaks, which are believed to be required for the initiation of gene amplification. This process may be promoted by heat when cellular proteins that are responsible for checkpoints, DNA replication, DNA repair and telomere functions are denatured. To our knowledge, this is the first study to provide direct evidence of hyperthermia induced gene amplification.

  6. First measurements with new high-resolution gadolinium-GEM neutron detectors

    CERN Document Server

    Pfeiffer, Dorothea; Birch, Jens; Etxegarai, Maddi; Hall-Wilton, Richard; Höglund, Carina; Hultman, Lars; Llamas-Jansa, Isabel; Oliveri, Eraldo; Oksanen, Esko; Robinson, Linda; Ropelewski, Leszek; Schmidt, Susann; Streli, Christina; Thuiner, Patrik

    2016-05-17

    European Spallation Source instruments like the macromolecular diffractometer, NMX, require an excellent neutron detection efficiency, high-rate capabilities, time resolution, and an unprecedented spatial resolution in the order of a few hundred micrometers over a wide angular range of the incoming neutrons. For these instruments solid converters in combination with Micro Pattern Gaseous Detectors (MPGDs) are a promising option. A GEM detector with gadolinium converter was tested on a cold neutron beam at the IFE research reactor in Norway. The {\\mu}TPC analysis, proven to improve the spatial resolution in the case of $^{10}$B converters, is extended to gadolinium based detectors. For the first time, a Gd-GEM was successfully operated to detect neutrons with an estimated efficiency of 10% at a wavelength of 2 {\\AA} and a position resolution better than 350 {\\mu}m.

  7. Commissioning and integration testing of the DAQ system for the CMS GEM upgrade

    CERN Document Server

    Castaneda Hernandez, Alfredo Martin

    2017-01-01

    The CMS muon system will undergo a series of upgrades in the coming years to preserve and extend its muon detection capabilities during the High Luminosity LHC.The first of these will be the installation of triple-foil GEM detectors in the CMS forward region with the goal of maintaining trigger rates and preserving good muon reconstruction, even in the expected harsh environment.In 2017 the CMS GEM project is looking to achieve a major milestone in the project with the installation of 5 super-chambers in CMS; this exercise will allow for the study of services installation and commissioning, and integration with the rest of the subsystems for the first time. An overview of the DAQ system will be given with emphasis on the usage during chamber quality control testing, commissioning in CMS, and integration with the central CMS system.

  8. Data Management and Other Logistical Challenges for the GEMS: The Data Coordinating Center Perspective

    Science.gov (United States)

    Biswas, Kousick; Carty, Christina; Horney, Rebecca; Nasrin, Dilruba; Farag, Tamer H.; Kotloff, Karen L.; Levine, Myron M.

    2012-01-01

    The Cooperative Studies Program Coordinating Center provided the data management, administrative, and statistical support to the Global Enteric Multicenter Study (GEMS). The GEMS study, the largest epidemiological study in the diarrheal disease area among children <5 years of age, was carried out in 4 African countries and 3 Asian countries. Given the geographical and geopolitical differences among the countries, the administration of a centralized data management operation was a major challenge. The sheer volume of the data that were collected, regular transfer of the data to a centralized database, and the cleaning of the same also posed some challenges. This paper outlines the details of the support that the data coordinating center provided and the challenges faced during the course of the study. PMID:23169938

  9. Operational experience with the GEM detector assembly lines for the CMS forward muon upgrade

    CERN Document Server

    Vai, Ilaria

    2017-01-01

    The CMS Collaboration has been developing large-area Triple-GEM detectors to be installed in the muon endcap regions of the CMS experiment in 2019 to maintain forward muon trigger and tracking performance at the HL-LHC. Ten pre-production detectors were built at CERN to commission the first assembly line and the quality controls. These were installed in the CMS detector in early 2017 and are currently participating in the 2017 LHC run. The collaboration has prepared several additional assembly and quality control lines for distributed mass production of 160 GEM detectors at various sites worldwide. During 2017, these additional production sites have been optimizing construction techniques and quality control procedures and validating them against common specifications by constructing additional pre-production detectors. Using the specific experience from one production site as an example, we discuss how the quality controls make use of independent hardware and trained personnel to ensure fast and reliable pro...

  10. Deoxygenative gem-difluoroolefination of carbonyl compounds with (chlorodifluoromethyltrimethylsilane and triphenylphosphine

    Directory of Open Access Journals (Sweden)

    Fei Wang

    2014-02-01

    Full Text Available Background: 1,1-Difluoroalkenes cannot only be used as valuable precursors for organic synthesis, but also act as bioisosteres for enzyme inhibitors. Among various methods for their preparation, the carbonyl olefination with difluoromethylene phosphonium ylide represents one of the most straightforward methods.Results: The combination of (chlorodifluoromethyltrimethylsilane (TMSCF2Cl and triphenylphosphine (PPh3 can be used for the synthesis of gem-difluoroolefins from carbonyl compounds. Comparative experiments demonstrate that TMSCF2Cl is superior to (bromodifluoromethyltrimethylsilane (TMSCF2Br and (trifluoromethyltrimethylsilane (TMSCF3 in this reaction.Conclusion: Similar to many other Wittig-type gem-difluoroolefination reactions in the presence of PPh3, the reaction of TMSCF2Cl with aldehydes and activated ketones is effective.

  11. Report from the II Melanoma Translational Meeting of the Spanish Melanoma Group (GEM)

    Science.gov (United States)

    Berrocal, Alfonso; Puig, Susana; Karachaliou, Niki; De Matos-Arruda, Leticia; Seoane, Joan; Escors, David; Alvarez, Carmen; Vaque, Jose Pedro; Prat, Aleix; Wellbrock, Claudia; Arozarena, Imanol; Marquez-Rodas, Ivan; Espinosa, Enrique; Molina, Migue Angel; Puertolas, Teresa; Juan-Otero, Manuel; Malagrida, Rosina; Jantus-Lewintre, Eloisa; Soriano, Virtudes; Arance, Ana; Manzano, Jose Luis; Lorigan, Paul; Gajewski, Thomas F.; Rosell, Rafael; Martin-Algarra, Salvador

    2017-01-01

    The II Melanoma Translational Meeting of the Spanish Melanoma Group (GEM) was held in Barcelona, Spain, at the Hospital Universitari Quiron-Dexeus on November 3rd, 2016. The conference featured leaders in the fields of oncology, immunology and dermatology, all working at both national and international levels on basic research with direct applications to the clinical setting. The objective was to present cutting edge research on melanoma, mainly from Spanish research groups, but also from some international groups, with the aim of generating a network for future national and international collaborations. During a single day, fifteen speakers, seven biologists and eight clinicians, with a special focus on translational research, outlined the main findings of their ongoing studies. The moderators in every session were recognized GEM oncologists who guided discussion from the clinical point of view regarding the preclinical data presented. Herein, we summarize the main topics discussed during the meeting.

  12. 100+ years of instrumental seismology: the example of the ISC-GEM Global Earthquake Instrumental Catalogue

    Science.gov (United States)

    Storchak, Dmitry; Di Giacomo, Domenico

    2015-04-01

    Systematic seismological observations of earthquakes using seismic instruments on a global scale began more than 100 years ago. Since then seismologists made many discoveries about the Earth interior and the physics of the earthquakes, also thanks to major developments in the seismic instrumentation deployed around the world. Besides, since the establishment of the first global networks (Milne and Jesuit networks), seismologists around the world stored and exchanged the results of routine observations (e.g., picking of arrival times, amplitude-period measurements, etc.) or more sophisticated analyses (e.g., moment tensor inversion) in seismological bulletins/catalogues. With a project funded by the GEM Foundation (www.globalquakemodel.org), the ISC and the Team of International Experts released a new global earthquake catalogue, the ISC-GEM Global Instrumental Earthquake Catalogue (1900 2009) (www.isc.ac.uk/iscgem/index.php), which, differently from previous global seismic catalogues, has the unique feature of covering the entire period of instrumental seismology with locations and magnitude re-assessed using modern approaches for the global earthquakes selected for processing (in the current version approximately 21,000). During the 110 years covered by the ISC-GEM catalogue many seismological developments occurred in terms of instrumentation, seismological practice and knowledge of the physics of the earthquakes. In this contribution we give a brief overview of the major milestones characterizing the last 100+ years of instrumental seismology that were relevant for the production of the ISC-GEM catalogue and the major challenges we faced to obtain a catalogue as homogenous as possible.

  13. Fast data transmission from serial data acquisition for the GEM detector system

    Science.gov (United States)

    Kolasinski, Piotr; Pozniak, Krzysztof T.; Czarski, Tomasz; Byszuk, Adrian; Chernyshova, Maryna; Kasprowicz, Grzegorz; Krawczyk, Rafal D.; Wojenski, Andrzej; Zabolotny, Wojciech

    2015-09-01

    This article proposes new method of storing data and transferring it to PC in the X-ray GEM detector system. The whole process is performed by FPGA chips (Spartan-6 series from Xilinx). Comparing to previous methods, new approach allows to store much more data in the system. New, improved implementation of the communication algorithm significantly increases transfer rate between system and PC. In PC data is merged and processed by MATLAB. The structure of firmware implemented in the FPGAs is described.

  14. Simulation of in-cloud icing events on Mount Washington with the GEM-LAM

    Science.gov (United States)

    Yang, Jing; Jones, Kathleen F.; Yu, Wei; Morris, Robert

    2012-09-01

    In-cloud icing on structures such as transmission lines and wind turbines is an important consideration both for design and operations. It often occurs in coastal areas and over high terrain, where there are virtually no systematic observations. The regional mesoscale model GEM-LAM of the Canadian Meteorological Center (CMC) was used to model three historical icing events on Mount Washington, where observational data were available. These three events are representative of the most frequent low level wind directions for seven available observation periods. A newly developed sophisticated two-moment microphysics scheme (Milbrandt-Yau) is used in GEM-LAM. The simulated cloud properties and other meteorological data are compared with near surface observational data. Simulation results from the 1-km resolution run agree best with the observations, with an average RMSE (root mean square error) of 1.6°C for near surface temperature, 4.6 m s-1 for wind speed, 0.23 g m-3 for liquid water content, and 5.8 μm for the median volume droplet diameter. These simulated meteorological fields and cloud properties were used as inputs to a cylindrical sleeve icing model. The modeled icing rate from the GEM-LAM simulated fields follows the temporal evolution of the observed one with average RMSE of 1.53 g m-1 min-1 compared to an average measured icing rate of 1.98 g m-1 min-1 for all the three cases.

  15. GEM, Fuel Cycle Cost and Economics for Thermal Reactor, Present Worth Analysis

    International Nuclear Information System (INIS)

    Hughes, J.A.; Hang, D.F.

    1974-01-01

    1- Description of problem or function: GEM is used to predict fuel cycle costs for any type nuclear system (i.e., BWR, HTGR, PWR, LMFBR, GCFR,... ). The current version is limited to thermal reactors. GEM is designed for production use by large utilities which have several reactor types on their system. GEM has been written so as to accommodate all major fuel management activities undertaken by a utility - (1) fuel bid analysis, (2) evaluation of actual day to day operation, and (3) system simulation and optimization studies. 2 - Method of solution: Costs are calculated using present-worth techniques and continuous compounding. The equations are based on an investor-owned utility capitalization structure which easily covers the range of industrial, private, and public (government) owned utilities. Three distinct types of analysis (cash flow, allocated costs, yearly cash flow) are performed, each yielding identical results. Using these as a basis many other analyses are undertaken. 3 - Restrictions on the complexity of the problem: Dimensions of all arrays are carried as variables throughout the analysis. The maximum size of each array is set by the user in program MAIN. Current values are set so that maxima are: 50 batches per case study, 20 year batch life, 30 year case study, 120 batch burn time-steps, 20 individual payments (sales) associated with each cost component

  16. A GEM readout with radial zigzag strips and linear charge-sharing response

    Science.gov (United States)

    Zhang, Aiwu; Hohlmann, Marcus; Azmoun, Babak; Purschke, Martin L.; Woody, Craig

    2018-04-01

    We study the position sensitivity of radial zigzag strips intended to read out large GEM detectors for tracking at future experiments. Zigzag strips can cover a readout area with fewer strips than regular straight strips while maintaining good spatial resolution. Consequently, they can reduce the number of required electronic channels and related cost for large-area GEM detector systems. A non-linear relation between incident particle position and hit position measured from charge sharing among zigzag strips was observed in a previous study. We significantly reduce this non-linearity by improving the interleaving of adjacent physical zigzag strips. Zigzag readout structures are implemented on PCBs and on a flexible foil and are tested using a 10 cm × 10 cm triple-GEM detector scanned with a strongly collimated X-ray gun on a 2D motorized stage. Angular resolutions of 60-84 μrad are achieved with a 1.37 mrad angular strip pitch at a radius of 784 mm. On a linear scale this corresponds to resolutions below 100 μm.

  17. Characterization of multilayer Thick-GEM geometries as 10B converters aiming thermal neutron detection

    Science.gov (United States)

    Natal da Luz, H.; Souza, F. A.; Moralles, M.; Carlin, N.; Oliveira, R. A. N.; Bregant, M.; Suaide, A. A. P.; Chubaci, J. F. D.; Matsuoka, M.; Silva, T. F.; Moro, M. V.; Rodrigues, C. L.; Munhoz, M. G.

    2018-02-01

    Boron-based thermal neutron detectors have recently regained some attention from the instrumentation community as a strong alternative to helium-3 detectors. From the existing concepts exploiting boron layers in position sensitive detectors, the Cascade [1] is the one that takes full advantage of the 2D capabilities of gaseous detectors, with the position resolution not limited by the architecture of the detector. In this work, a proposal for the Cascade detector, based on Thick-GEMs is presented, together with some preliminary studies of the suitable pitch that optimizes the neutron conversion efficiency, while keeping the collection efficiency intact. The characterization of Thick-GEM prototypes produced in Brazil with hole pitch from 0.75 to 3 mm shows that these devices already present a stable performance at low gains, also resulting in fair energy resolution, when cascaded with a standard KaptonTM 50 µm GEM. Results of the first attempts of boron film depositions with Ion Beam Assisted Deposition and characterization by Ion Beam Analysis are also presented.

  18. Integrated Farm System Model Version 4.3 and Dairy Gas Emissions Model Version 3.3 Software development and distribution

    Science.gov (United States)

    Modeling routines of the Integrated Farm System Model (IFSM version 4.2) and Dairy Gas Emission Model (DairyGEM version 3.2), two whole-farm simulation models developed and maintained by USDA-ARS, were revised with new components for: (1) simulation of ammonia (NH3) and greenhouse gas emissions gene...

  19. ESTIMATION OF AMPLIFICATION FACTOR IN EARTHQUAKE ENGINEERING

    Directory of Open Access Journals (Sweden)

    Nazarov Yuriy Pavlovich

    2015-03-01

    Full Text Available The authors are the developers of Odyssey Software (Eurosoft Co. for the analysis of seismological data and computing of seismic loads and their parameters. While communicating with the users of the software, the authors have revealed some uncertainty about both understanding of the term "amplification factor (AF" and calculation of the amplification factor using various methods. In this article, a simple example shows that the determination of the amplification factor as the ratio of the acceleration’s spectrum to the maximal acceleration is derived from the classical definition of AF in the form of the ratio of maximal dynamic displacement to the displacement by the action of static load. Deterministic and probabilistic ap-proaches for the calculating of the AF were discussed. There was an example of AFs calculation and their envelopes for translational and rotational components of seismic impact by using Odyssey Software.

  20. Time varying arctic climate change amplification

    Energy Technology Data Exchange (ETDEWEB)

    Chylek, Petr [Los Alamos National Laboratory; Dubey, Manvendra K [Los Alamos National Laboratory; Lesins, Glen [DALLHOUSIE U; Wang, Muyin [NOAA/JISAO

    2009-01-01

    During the past 130 years the global mean surface air temperature has risen by about 0.75 K. Due to feedbacks -- including the snow/ice albedo feedback -- the warming in the Arctic is expected to proceed at a faster rate than the global average. Climate model simulations suggest that this Arctic amplification produces warming that is two to three times larger than the global mean. Understanding the Arctic amplification is essential for projections of future Arctic climate including sea ice extent and melting of the Greenland ice sheet. We use the temperature records from the Arctic stations to show that (a) the Arctic amplification is larger at latitudes above 700 N compared to those within 64-70oN belt, and that, surprisingly; (b) the ratio of the Arctic to global rate of temperature change is not constant but varies on the decadal timescale. This time dependence will affect future projections of climate changes in the Arctic.

  1. Amplification, Redundancy, and Quantum Chernoff Information

    Science.gov (United States)

    Zwolak, Michael; Riedel, C. Jess; Zurek, Wojciech H.

    2014-04-01

    Amplification was regarded, since the early days of quantum theory, as a mysterious ingredient that endows quantum microstates with macroscopic consequences, key to the "collapse of the wave packet," and a way to avoid embarrassing problems exemplified by Schrödinger's cat. Such a bridge between the quantum microworld and the classical world of our experience was postulated ad hoc in the Copenhagen interpretation. Quantum Darwinism views amplification as replication, in many copies, of the information about quantum states. We show that such amplification is a natural consequence of a broad class of models of decoherence, including the photon environment we use to obtain most of our information. This leads to objective reality via the presence of robust and widely accessible records of selected quantum states. The resulting redundancy (the number of copies deposited in the environment) follows from the quantum Chernoff information that quantifies the information transmitted by a typical elementary subsystem of the environment.

  2. Gravitational Wave Detection via Weak Measurements Amplification

    OpenAIRE

    Hu, Meng-Jun; Zhang, Yong-Sheng

    2017-01-01

    A universal amplification scheme of ultra-small phase based on weak measurements is given and a weak measurements amplification based laser interferometer gravitational-wave observatory (WMA-LIGO) is suggested. The WMA-LIGO has potential to amplify the ultra-small phase signal to at least $10^{3}$ order of magnitude such that the sensitivity and bandwidth of gravitational-wave detector can be further improved. Our results not only shed a new light on the quantum measurement but also open a ne...

  3. ISC-GEM: Global Instrumental Earthquake Catalogue (1900-2009), II. Location and seismicity patterns

    Science.gov (United States)

    Bondár, I.; Engdahl, E. Robert; Villaseñor, A.; Harris, James; Storchak, D.

    2015-02-01

    We present the final results of a two-year project sponsored by the Global Earthquake Model (GEM) Foundation. The ISC-GEM global catalogue consists of some 19 thousand instrumentally recorded, moderate to large earthquakes, spanning 110 years of seismicity. We relocated all events in the catalogue using a two-tier approach. The EHB location methodology (Engdahl et al., 1998) was applied first to obtain improved hypocentres with special focus on the depth determination. The locations were further refined in the next step by fixing the depths to those from the EHB analysis and applying the new International Seismological Centre (ISC) location algorithm (Bondár and Storchak, 2011) that reduces location bias by accounting for correlated travel-time prediction error structure. To facilitate the relocation effort, some one million seismic P and S wave arrival-time data were added to the ISC database for the period between 1904 and 1970, either from original station bulletins in the ISC archive or by digitizing the scanned images of the International Seismological Summary (ISS) bulletin (Villaseñor and Engdahl, 2005, 2007). Although no substantial amount of new phase data were acquired for the modern period (1964-2009), the number of phases used in the location has still increased by three millions, owing to fact that both the EHB and ISC locators use most well-recorded ak135 (Kennett et al., 1995) phases in the location. We show that the relocation effort yielded substantially improved locations, especially in the first half of the 20th century; we demonstrate significant improvements in focal depth estimates in subduction zones and other seismically active regions; and we show that the ISC-GEM catalogue provides an improved view of 110 years of global seismicity of the Earth. The ISC-GEM Global Instrumental Earthquake Catalogue represents the final product of one of the ten global components in the GEM program, and is available to researchers at the ISC (http://www.isc.ac.uk).

  4. GEM-TREND: a web tool for gene expression data mining toward relevant network discovery.

    Science.gov (United States)

    Feng, Chunlai; Araki, Michihiro; Kunimoto, Ryo; Tamon, Akiko; Makiguchi, Hiroki; Niijima, Satoshi; Tsujimoto, Gozoh; Okuno, Yasushi

    2009-09-03

    DNA microarray technology provides us with a first step toward the goal of uncovering gene functions on a genomic scale. In recent years, vast amounts of gene expression data have been collected, much of which are available in public databases, such as the Gene Expression Omnibus (GEO). To date, most researchers have been manually retrieving data from databases through web browsers using accession numbers (IDs) or keywords, but gene-expression patterns are not considered when retrieving such data. The Connectivity Map was recently introduced to compare gene expression data by introducing gene-expression signatures (represented by a set of genes with up- or down-regulated labels according to their biological states) and is available as a web tool for detecting similar gene-expression signatures from a limited data set (approximately 7,000 expression profiles representing 1,309 compounds). In order to support researchers to utilize the public gene expression data more effectively, we developed a web tool for finding similar gene expression data and generating its co-expression networks from a publicly available database. GEM-TREND, a web tool for searching gene expression data, allows users to search data from GEO using gene-expression signatures or gene expression ratio data as a query and retrieve gene expression data by comparing gene-expression pattern between the query and GEO gene expression data. The comparison methods are based on the nonparametric, rank-based pattern matching approach of Lamb et al. (Science 2006) with the additional calculation of statistical significance. The web tool was tested using gene expression ratio data randomly extracted from the GEO and with in-house microarray data, respectively. The results validated the ability of GEM-TREND to retrieve gene expression entries biologically related to a query from GEO. For further analysis, a network visualization interface is also provided, whereby genes and gene annotations are dynamically

  5. GEM-E3: A computable general equilibrium model applied for Switzerland

    Energy Technology Data Exchange (ETDEWEB)

    Bahn, O. [Paul Scherrer Inst., CH-5232 Villigen PSI (Switzerland); Frei, C. [Ecole Polytechnique Federale de Lausanne (EPFL) and Paul Scherrer Inst. (Switzerland)

    2000-01-01

    The objectives of the European Research Project GEM-E3-ELITE, funded by the European Commission and coordinated by the Centre for European Economic Research (Germany), were to further develop the general equilibrium model GEM-E3 (Capros et al., 1995, 1997) and to conduct policy analysis through case studies. GEM-E3 is an applied general equilibrium model that analyses the macro-economy and its interaction with the energy system and the environment through the balancing of energy supply and demand, atmospheric emissions and pollution control, together with the fulfillment of overall equilibrium conditions. PSI's research objectives within GEM-E3-ELITE were to implement and apply GEM-E3 for Switzerland. The first objective required in particular the development of a Swiss database for each of GEM-E3 modules (economic module and environmental module). For the second objective, strategies to reduce CO{sub 2} emissions were evaluated for Switzerland. In order to develop the economic, PSI collaborated with the Laboratory of Applied Economics (LEA) of the University of Geneva and the Laboratory of Energy Systems (LASEN) of the Federal Institute of Technology in Lausanne (EPFL). The Swiss Federal Statistical Office (SFSO) and the Institute for Business Cycle Research (KOF) of the Swiss Federal Institute of Technology (ETH Zurich) contributed also data. The Swiss environmental database consists mainly of an Energy Balance Table and of an Emission Coefficients Table. Both were designed using national and international official statistics. The Emission Coefficients Table is furthermore based on know-how of the PSI GaBE Project. Using GEM-E3 Switzerland, two strategies to reduce the Swiss CO{sub 2} emissions were evaluated: a carbon tax ('tax only' strategy), and the combination of a carbon tax with the buying of CO{sub 2} emission permits ('permits and tax' strategy). In the first strategy, Switzerland would impose the necessary carbon tax to achieve

  6. GEM-E3: A computable general equilibrium model applied for Switzerland

    International Nuclear Information System (INIS)

    Bahn, O.; Frei, C.

    2000-01-01

    The objectives of the European Research Project GEM-E3-ELITE, funded by the European Commission and coordinated by the Centre for European Economic Research (Germany), were to further develop the general equilibrium model GEM-E3 (Capros et al., 1995, 1997) and to conduct policy analysis through case studies. GEM-E3 is an applied general equilibrium model that analyses the macro-economy and its interaction with the energy system and the environment through the balancing of energy supply and demand, atmospheric emissions and pollution control, together with the fulfillment of overall equilibrium conditions. PSI's research objectives within GEM-E3-ELITE were to implement and apply GEM-E3 for Switzerland. The first objective required in particular the development of a Swiss database for each of GEM-E3 modules (economic module and environmental module). For the second objective, strategies to reduce CO 2 emissions were evaluated for Switzerland. In order to develop the economic, PSI collaborated with the Laboratory of Applied Economics (LEA) of the University of Geneva and the Laboratory of Energy Systems (LASEN) of the Federal Institute of Technology in Lausanne (EPFL). The Swiss Federal Statistical Office (SFSO) and the Institute for Business Cycle Research (KOF) of the Swiss Federal Institute of Technology (ETH Zurich) contributed also data. The Swiss environmental database consists mainly of an Energy Balance Table and of an Emission Coefficients Table. Both were designed using national and international official statistics. The Emission Coefficients Table is furthermore based on know-how of the PSI GaBE Project. Using GEM-E3 Switzerland, two strategies to reduce the Swiss CO 2 emissions were evaluated: a carbon tax ('tax only' strategy), and the combination of a carbon tax with the buying of CO 2 emission permits ('permits and tax' strategy). In the first strategy, Switzerland would impose the necessary carbon tax to achieve the reduction target, and use the tax

  7. Optical Pattern Recognition With Self-Amplification

    Science.gov (United States)

    Liu, Hua-Kuang

    1994-01-01

    In optical pattern recognition system with self-amplification, no reference beam used in addressing mode. Polarization of laser beam and orientation of photorefractive crystal chosen to maximize photorefractive effect. Intensity of recognition signal is orders of magnitude greater than other optical correlators. Apparatus regarded as real-time or quasi-real-time optical pattern recognizer with memory and reprogrammability.

  8. Social amplification of risk: a conceptual framework

    International Nuclear Information System (INIS)

    Kasperson, R.E.; Renn, O.; Slovic, P.; Brown, H.S.; Emel, J.; Goble, R.; Kasperson, J.X.; Ratick, S.

    1988-01-01

    One of the most perplexing problems in risk analysis is why some relatively minor risks or risk events, as assessed by technical experts, often elicit strong public concerns and result in substantial impacts upon society and economy. This article sets forth a conceptual framework that seeks to link systematically the technical assessment of risk with psychological, sociological, and cultural perspectives of risk perception and risk-related behavior. The main thesis is that hazards interact with psychological, social, institutional, and cultural processes in ways that may amplify or attenuate public responses to the risk or risk event. A structural description of the social amplification of risk is now possible. Amplification occurs at two stages: in the transfer of information about the risk, and in the response mechanisms of society. Signals about risk are processed by individual and social amplification stations, including the scientist who communicates the risk assessment, the news media, cultural groups, interpersonal networks, and others. Key steps of amplifications can be identified at each stage. The amplified risk leads to behavioral responses, which, in turn, result in secondary impacts. Models are presented that portray the elements and linkages in the proposed conceptual framework

  9. Desert Amplification in a Warming Climate

    Science.gov (United States)

    Zhou, Liming

    2016-01-01

    Here I analyze the observed and projected surface temperature anomalies over land between 50°S-50°N for the period 1950–2099 by large-scale ecoregion and find strongest warming consistently and persistently seen over driest ecoregions such as the Sahara desert and the Arabian Peninsula during various 30-year periods, pointing to desert amplification in a warming climate. This amplification enhances linearly with the global mean greenhouse gases(GHGs) radiative forcing and is attributable primarily to a stronger GHGs-enhanced downward longwave radiation forcing reaching the surface over drier ecoregions as a consequence of a warmer and thus moister atmosphere in response to increasing GHGs. These results indicate that desert amplification may represent a fundamental pattern of global warming associated with water vapor feedbacks over land in low- and mid- latitudes where surface warming rates depend inversely on ecosystem dryness. It is likely that desert amplification might involve two types of water vapor feedbacks that maximize respectively in the tropical upper troposphere and near the surface over deserts, with both being very dry and thus extremely sensitive to changes of water vapor. PMID:27538725

  10. Intelligence amplification framework for enhancing scheduling processes

    NARCIS (Netherlands)

    Dobrkovic, Andrej; Liu, Luyao; Iacob, Maria Eugenia; van Hillegersberg, Jos

    2016-01-01

    The scheduling process in a typical business environment consists of predominantly repetitive tasks that have to be completed in limited time and often containing some form of uncertainty. The intelligence amplification is a symbiotic relationship between a human and an intelligent agent. This

  11. Optical parametric amplification beyond the slowly varying ...

    Indian Academy of Sciences (India)

    The coupled-wave equations describing optical parametric amplification (OPA) are usually solved in the slowly varying amplitude (SVA) approximation regime, in which the second-order derivatives of the signal and idler amplitudes are ignored and in fact the electromagnetic effects due to exit face of the medium is not ...

  12. (PCR) and loop-mediated isothermal amplification

    African Journals Online (AJOL)

    SAM

    2014-03-26

    Mar 26, 2014 ... better alternative for PCR, even in low technology laboratories. In addition, these findings revealed that the possibility of fatal fusariosis due to F. solani is not so rare in HIV positive patients. Key words: Fusarium solani, loop-mediated isothermal amplification (LAMP), HIV, polymerase chain reaction. (PCR).

  13. Desert Amplification in a Warming Climate.

    Science.gov (United States)

    Zhou, Liming

    2016-08-19

    Here I analyze the observed and projected surface temperature anomalies over land between 50°S-50°N for the period 1950-2099 by large-scale ecoregion and find strongest warming consistently and persistently seen over driest ecoregions such as the Sahara desert and the Arabian Peninsula during various 30-year periods, pointing to desert amplification in a warming climate. This amplification enhances linearly with the global mean greenhouse gases(GHGs) radiative forcing and is attributable primarily to a stronger GHGs-enhanced downward longwave radiation forcing reaching the surface over drier ecoregions as a consequence of a warmer and thus moister atmosphere in response to increasing GHGs. These results indicate that desert amplification may represent a fundamental pattern of global warming associated with water vapor feedbacks over land in low- and mid- latitudes where surface warming rates depend inversely on ecosystem dryness. It is likely that desert amplification might involve two types of water vapor feedbacks that maximize respectively in the tropical upper troposphere and near the surface over deserts, with both being very dry and thus extremely sensitive to changes of water vapor.

  14. The Mitochondrial GTPase Gem1 Contributes to the Cell Wall Stress Response and Invasive Growth of Candida albicans

    Directory of Open Access Journals (Sweden)

    Barbara Koch

    2017-12-01

    Full Text Available The interactions of mitochondria with the endoplasmic reticulum (ER are crucial for maintaining proper mitochondrial morphology, function and dynamics. This enables cells to utilize their mitochondria optimally for energy production and anabolism, and it further provides for metabolic control over developmental decisions. In fungi, a key mechanism by which ER and mitochondria interact is via a membrane tether, the protein complex ERMES (ER-Mitochondria Encounter Structure. In the model yeast Saccharomyces cerevisiae, the mitochondrial GTPase Gem1 interacts with ERMES, and it has been proposed to regulate its activity. Here we report on the first characterization of Gem1 in a human fungal pathogen. We show that in Candida albicans Gem1 has a dominant role in ensuring proper mitochondrial morphology, and our data is consistent with Gem1 working with ERMES in this role. Mitochondrial respiration and steady state cellular phospholipid homeostasis are not impacted by inactivation of GEM1 in C. albicans. There are two major virulence-related consequences of disrupting mitochondrial morphology by GEM1 inactivation: C. albicans becomes hypersusceptible to cell wall stress, and is unable to grow invasively. In the gem1Δ/Δ mutant, it is specifically the invasive capacity of hyphae that is compromised, not the ability to transition from yeast to hyphal morphology, and this phenotype is shared with ERMES mutants. As a consequence of the hyphal invasion defect, the gem1Δ/Δ mutant is drastically hypovirulent in the worm infection model. Activation of the mitogen activated protein (MAP kinase Cek1 is reduced in the gem1Δ/Δ mutant, and this function could explain both the susceptibility to cell wall stress and lack of invasive growth. This result establishes a new, respiration-independent mechanism of mitochondrial control over stress signaling and hyphal functions in C. albicans. We propose that ER-mitochondria interactions and the ER

  15. Gaseous flat-panel detector with glass gas electron multiplier coupled with micro-photodiode array

    Science.gov (United States)

    Mitsuya, Yuki; Miyoshi, Hiroaki; Fujiwara, Takeshi; Uesaka, Mitsuru; Takahashi, Hiroyuki

    2017-11-01

    In this study, we propose and demonstrate a novel imaging system, a gaseous flat-panel detector (FPD). The gaseous FPD consists of a glass gas electron multiplier (G-GEM) with a scintillation gas, which is optically coupled with photodiode panel fabricated with liquid crystal display technology. The G-GEM is ideal as a low energy deposition radiation detector because of its single stage high gas-gain and hence, its high photon yield. We obtained a preliminary X-ray image with the system by using a Ne/CF4 90/10 gas mixture. The typical position resolution was 0.93 mm in FWHM, which was obtained from the fitting of edge profiles

  16. Divergent mechanistic routes for the formation of gem-dimethyl groups in the biosynthesis of complex polyketides.

    Science.gov (United States)

    Poust, Sean; Phelan, Ryan M; Deng, Kai; Katz, Leonard; Petzold, Christopher J; Keasling, Jay D

    2015-02-16

    The gem-dimethyl groups in polyketide-derived natural products add steric bulk and, accordingly, lend increased stability to medicinal compounds, however, our ability to rationally incorporate this functional group in modified natural products is limited. In order to characterize the mechanism of gem-dimethyl group formation, with a goal toward engineering of novel compounds containing this moiety, the gem-dimethyl group producing polyketide synthase (PKS) modules of yersiniabactin and epothilone were characterized using mass spectrometry. The work demonstrated, contrary to the canonical understanding of reaction order in PKSs, that methylation can precede condensation in gem-dimethyl group producing PKS modules. Experiments showed that both PKSs are able to use dimethylmalonyl acyl carrier protein (ACP) as an extender unit. Interestingly, for epothilone module 8, use of dimethylmalonyl-ACP appeared to be the sole route to form a gem-dimethylated product, while the yersiniabactin PKS could methylate before or after ketosynthase condensation. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Design and implementation of the infrastructure of HadGEM3: the next-generation Met Office climate modelling system

    Directory of Open Access Journals (Sweden)

    H. T. Hewitt

    2011-04-01

    Full Text Available This paper describes the development of a technically robust climate modelling system, HadGEM3, which couples the Met Office Unified Model atmosphere component, the NEMO ocean model and the Los Alamos sea ice model (CICE using the OASIS coupler. Details of the coupling and technical solutions of the physical model (HadGEM3-AO are documented, in addition to a description of the configurations of the individual submodels. The paper demonstrates that the implementation of the model has resulted in accurate conservation of heat and freshwater across the model components. The model performance in early versions of this climate model is briefly described to demonstrate that the results are scientifically credible. HadGEM3-AO is the basis for a number of modelling efforts outside of the Met Office, both within the UK and internationally. This documentation of the HadGEM3-AO system provides a detailed reference for developers of HadGEM3-based climate configurations.

  18. Plasmonic Terahertz Amplification in Graphene-Based Asymmetric Hyperbolic Metamaterial

    Directory of Open Access Journals (Sweden)

    Igor Nefedov

    2015-05-01

    Full Text Available We propose and theoretically explore terahertz amplification, based on stimulated generation of plasmons in graphene asymmetric hyperbolic metamaterials (AHMM, strongly coupled to terahertz radiation. In contrast to the terahertz amplification in resonant nanocavities, AHMM provides a wide-band THz amplification without any reflection in optically thin graphene multilayers.

  19. Depth of Response in Multiple Myeloma: A Pooled Analysis of Three PETHEMA/GEM Clinical Trials.

    Science.gov (United States)

    Lahuerta, Juan-Jose; Paiva, Bruno; Vidriales, Maria-Belen; Cordón, Lourdes; Cedena, Maria-Teresa; Puig, Noemi; Martinez-Lopez, Joaquin; Rosiñol, Laura; Gutierrez, Norma C; Martín-Ramos, María-Luisa; Oriol, Albert; Teruel, Ana-Isabel; Echeveste, María-Asunción; de Paz, Raquel; de Arriba, Felipe; Hernandez, Miguel T; Palomera, Luis; Martinez, Rafael; Martin, Alejandro; Alegre, Adrian; De la Rubia, Javier; Orfao, Alberto; Mateos, María-Victoria; Blade, Joan; San-Miguel, Jesus F

    2017-09-01

    Purpose To perform a critical analysis on the impact of depth of response in newly diagnosed multiple myeloma (MM). Patients and Methods Data were analyzed from 609 patients who were enrolled in the GEM (Grupo Español de Mieloma) 2000 and GEM2005MENOS65 studies for transplant-eligible MM and the GEM2010MAS65 clinical trial for elderly patients with MM who had minimal residual disease (MRD) assessments 9 months after study enrollment. Median follow-up of the series was 71 months. Results Achievement of complete remission (CR) in the absence of MRD negativity was not associated with prolonged progression-free survival (PFS) and overall survival (OS) compared with near-CR or partial response (median PFS, 27, 27, and 29 months, respectively; median OS, 59, 64, and 65 months, respectively). MRD-negative status was strongly associated with prolonged PFS (median, 63 months; P < .001) and OS (median not reached; P < .001) overall and in subgroups defined by prior transplantation, disease stage, and cytogenetics, with prognostic superiority of MRD negativity versus CR particularly evident in patients with high-risk cytogenetics. Accordingly, Harrell C statistics showed higher discrimination for both PFS and OS in Cox models that included MRD (as opposed to CR) for response assessment. Superior MRD-negative rates after different induction regimens anticipated prolonged PFS. Among 34 MRD-negative patients with MM and a phenotypic pattern of bone marrow involvement similar to monoclonal gammopathy of undetermined significance at diagnosis, the probability of "operational cure" was high; median PFS was 12 years, and the 10-year OS rate was 94%. Conclusion Our results demonstrate that MRD-negative status surpasses the prognostic value of CR achievement for PFS and OS across the disease spectrum, regardless of the type of treatment or patient risk group. MRD negativity should be considered as one of the most relevant end points for transplant-eligible and elderly fit patients

  20. First Year K-12 Teachers as High Leverage Point to Implement GEMS Space Science Curriculum Sequence

    Science.gov (United States)

    Slater, Timothy F.; Mendez, B. J.; Schultz, G.; Wierman, T.

    2013-01-01

    The recurring challenge for curriculum developers is how to efficiently prepare K-12 classroom teachers to use new curricula. First-year teachers, numbering nearly 250,000 in the US each year, have the greatest potential to impact the largest number of students because they have potential to be in the classroom for thirty years. At the same time, these novice teachers are often the most open minded about adopting curricular innovation because they are not yet deeply entrenched in existing practices. To take advantage of this high leverage point, a collaborative of space scientists and science educators at the University of California, Berkeley’s Lawrence Hall of Science and Center for Science Education at the Space Sciences Laboratory with experts from the Astronomical Society of the Pacific, the University of Wyoming, and the CAPER Center for Astronomy & Physics Education experimented with a unique professional development model focused on helping master teachers work closely with pre-service teachers during their student teaching internship field experience. The Advancing Mentor and Novice Teachers in Space Science (AMANTISS) team first identified master teachers who supervise novice, student teachers and trained these master teachers to use the GEMS Space Science Curriculum Sequence. Then, these master teachers were mentored in coaching interning student teachers assigned to them in using GEMS materials. Evaluation showed that novice teachers mentored by the master teachers felt knowledgeable after teaching the GEMS units. However, they seemed relatively less confident about the solar system and objects beyond the solar system. Overall, mentees felt strongly at the end of the year that they have acquired good strategies for teaching the various topics, suggesting that the support they received while teaching and working with a mentor was of real benefit to them. Funding provided in part by NASA ROSES AMANTISS NNX09AD51G

  1. Cytogenetic monitoring of personnel occupationally exposed to microwave radiation of GEM radar

    International Nuclear Information System (INIS)

    Garaj-Vrhovac, Vera; Gajski, Goran; Brumen, Vlatka

    2008-01-01

    In the present study we analyzed and followed-up on the DNA damaging effects of microwave radiation of GEM radar equipment within microwave field of 10 μW/cm 2 to 10 mW/cm 2 in personnel occupationally exposed to frequency range of 1.5 GHz to 10.9 GHz. The single cell gel electrophoresis (SCGE)/comet assay as a tool for the bio monitoring of individuals accidentally, environmentally or occupationally exposed to physical or chemical agents was used to evaluate possible genotoxic effect on peripheral human blood lymphocytes. The comet assay is a method that allows efficient determination of single strand breaks (SSB) and double-strand breaks (DSB), as well as alkali-labile sites in the DNA of single cells. The comet assay was carried out under alkaline conditions. We measured the baseline comet assay effect in whole blood samples. Parameter of the comet assay was studied in workers occupationally exposed to microwave radiation of GEM radar and in corresponding unexposed control subjects. It was found that in the subjects who were occupationally exposed to microwave radiation, the levels of DNA damage increased compare to control group and showed interindividual variations. As a measure of DNA damage tail length was used, calculated from the centre of the head and presented in micrometers (μm). Mean value of exposed group was 13.54±1.44 as opposed to control mean value that was 13.15±1.39. Differences between mean tail lengths were statistically significant (P<0.05, ANOVA). The results of this study indicate that individuals occupationally exposed to microwave frequency of GEM radar equipment may experience an increased genotoxic risk, emphasizing the importance of individual bio monitoring, limiting exposure and radiation safety programs. (author)

  2. Trace elemental analysis of Indian natural moonstone gems by PIXE and XRD techniques

    International Nuclear Information System (INIS)

    Venkateswara Rao, R.; Venkateswarulu, P.; Kasipathi, C.; SivaJyothi, S.

    2013-01-01

    A selected number of Indian Eastern Ghats natural moonstone gems were studied with a powerful nuclear analytical and non-destructive Proton Induced X-ray Emission (PIXE) technique. Thirteen elements, including V, Co, Ni, Zn, Ga, Ba and Pb, were identified in these moonstones and may be useful in interpreting the various geochemical conditions and the probable cause of their inceptions in the moonstone gemstone matrix. Furthermore, preliminary XRD studies of different moonstone patterns were performed. The PIXE technique is a powerful method for quickly determining the elemental concentration of a substance. A 3 MeV proton beam was employed to excite the samples. The chemical constituents of moonstones from parts of the Eastern Ghats geological formations of Andhra Pradesh, India were determined, and gemological studies were performed on those gems. The crystal structure and the lattice parameters of the moonstones were estimated using X-Ray Diffraction studies, trace and minor elements were determined using the PIXE technique, and major compositional elements were confirmed by XRD. In the present work, the usefulness and versatility of the PIXE technique for research in geo-scientific methodology is established. - Highlights: • For the first time, PIXE technique was employed to analyze the East Indian natural moonstone gems. • The trace and minor elements are estimated using PIXE technique whereas major compositional elements are confirmed by XRD. • Adularia variety of moonstone is found to be abundant in the present study. • The PIXE analysis concludes that Eastern Ghats of India are rich not only in gemstones but also in trace elements

  3. RNA amplification for successful gene profiling analysis

    Directory of Open Access Journals (Sweden)

    Wang Ena

    2005-07-01

    Full Text Available Abstract The study of clinical samples is often limited by the amount of material available to study. While proteins cannot be multiplied in their natural form, DNA and RNA can be amplified from small specimens and used for high-throughput analyses. Therefore, genetic studies offer the best opportunity to screen for novel insights of human pathology when little material is available. Precise estimates of DNA copy numbers in a given specimen are necessary. However, most studies investigate static variables such as the genetic background of patients or mutations within pathological specimens without a need to assess proportionality of expression among different genes throughout the genome. Comparative genomic hybridization of DNA samples represents a crude exception to this rule since genomic amplification or deletion is compared among different specimens directly. For gene expression analysis, however, it is critical to accurately estimate the proportional expression of distinct RNA transcripts since such proportions directly govern cell function by modulating protein expression. Furthermore, comparative estimates of relative RNA expression at different time points portray the response of cells to environmental stimuli, indirectly informing about broader biological events affecting a particular tissue in physiological or pathological conditions. This cognitive reaction of cells is similar to the detection of electroencephalographic patterns which inform about the status of the brain in response to external stimuli. As our need to understand human pathophysiology at the global level increases, the development and refinement of technologies for high fidelity messenger RNA amplification have become the focus of increasing interest during the past decade. The need to increase the abundance of RNA has been met not only for gene specific amplification, but, most importantly for global transcriptome wide, unbiased amplification. Now gene

  4. Comparison of the Soil Dynamic Amplification Factor and Soil Amplification by Using Microtremor and MASW Methods Respectively

    Science.gov (United States)

    Tuncel, Aykut; Cevdet Özdag, Özkan; Pamuk, Eren; Akgün, Mustafa

    2017-12-01

    Single Station Microtremor method, which is widely used nowadays, is an effective and easy applicable method. In this study, dynamic amplification factor distributions of the study area were obtained using scenario earthquake parameters with single station microtremor data gathered at 112 points. In addition, a surface wave active method, which is known as MASW (Multichannel Analysis of Surface Waves), was applied at 43 profiles to calculate the soil amplification values. Dynamic amplification factor (DAF), soil amplification, the predominant soil period (PSP), geology and topography data of the study area were analysed together. Dynamic amplification factor and soil amplification values were obtained 2 or higher at about sea level parts of the study area which are generally composed of alluvial units. Additionally, in high altitude regions that are composed of volcanic rocks, relatively lower dynamic amplification factor and soil amplification values were obtained. The minimum amplification value in the study area was 1.15, while the maximum amplification value was 3.05 according to the dynamic amplification results and the soil amplification values were between 1.16 and 3.85 in harmony. It is seen that the obtained DAF values and the soil amplification values calculated from the seismic velocities are very similar to each other numerically and regionally. Because of this, it is concluded that the values of the soil amplification obtained by the MASW method and the calculated DAF values in this study are in harmony with each other. Although the depths of research in these two calculation methods are different from each other, the similarity of the results allows us to arrive at the result of how effective the ground layer is on the amplification. It has a great importance to calculate the amplification values and other dynamic parameters by in situ measurements for a planned plot because geological units can vary even at very short distances in heterogeneously

  5. Surface Features and Cathodoluminescence (CL) Characteristics of Corundum Gems from Eastern of Thailand

    Science.gov (United States)

    Boonsoong, A.

    2017-12-01

    Thailand has long been well known as a supplier of gemstones and also one of the world's color stone centers for decades. The principal gemstones are corundum, garnet and zircon. The corundum deposits of Chanthaburi-Trat Provinces form the most significant ruby-sapphire concentration in Thailand. Corundums are commonly found in secondary deposits (alluvium, elluvial, residual-soil and colluvium deposits as well as stream sediments) with the thickness of the gem-bearing layer varying from 10-100cm and the thickness of the overburden ranging up to 15m. A number of corundum samples were collected from each of the twenty-nine corundum deposits in the Chanthaburi-Trat gem fields, eastern of Thailand. Corundum varies in colour across the region with colours associated with three geographic zones; a western zone, characterized by blue, green and yellow sapphires; a middle zone with blue, green sapphires plus rubies; and an eastern zone yielding mainly rubies. This project has aim to study surface features and characterize the Cathodoluminescence (CL) of corundum gems in the Chanthaburi-Trat gem fields, Thailand. Surfaces of the corundums under a scanning electron microscope show triangular etch features and randomly oriented needle-like patterns. These reveal that the corundums have interacted with the magma during their ascent to the Earth's surface. Surface features attributable to transport and weathering processes are scratches, conchoidal fractures and a spongy surface appearance. Clay minerals and Fe-Ti oxide minerals deposited on the spongy surfaces of some corundums also indicate that these grains experienced chemical weathering or reacted with the soil solution while they were in the alluvium. Cathodoluminescence shows some blue sapphires to exhibit dull blue luminescence. The main cause of the CL appearance of sapphires is likely to be a quench centre, Fe2+ in their structure. The bright red luminescence in corundum reflects a high Cr3+ content and is always

  6. The BlackGEM array in search of black hole mergers: integrated performance modelling

    Science.gov (United States)

    Roelfsema, Ronald; Klein Wolt, Marc; Bloemen, Steven; Groot, Paul; Bettonvil, Felix; Balster, Harry; Dolron, Peter; van Elteren, Arjen; Engels, Arno; de Haan, Menno; ter Horst, Rik; Kragt, Jan; Navarro, Ramon; Nelemans, Gijs; Paalberends, Willem Jelle; Pal, Sari; Raskin, Gert; Rutten, Harrie; Scheers, Bart; Schuil, Menno; Sybilski, Piotr

    2016-07-01

    The Radboud University Nijmegen in collaboration with the NOVA Optical Infrared Instrumentation group at ASTRON is currently leading the development and realization of the BlackGEM observing facility. The BlackGEM science team aims to be the first to catch the optical counterpart of a gravitational wave event. The BlackGEM project will put an array of three medium-sized optical telescopes at the La Silla site of the European Southern Observatory in Chile. It is uniquely equipped to achieve a combination of wide-field and high sensitivity through its array-like approach. Each BlackGEM unit telescope is a modified Dall-Kirkham-type telescope consisting of a 65cm primary mirror, a 21cm spherical secondary mirror and a triplet corrector lens. The spatial resolution on the sky will be 0.56 asec/pixel and the total field-of-view per telescope is 2.7 square degrees. The main requirement is to achieve a 5-sigma sensitivity of 23rd magnitude within a 5-minute exposure under 15 m/s wind gust conditions. This demands a very stable optical system with tight control of all the error contributions. This has been realized with a spreadsheet based integrated instrument model. The model contains all relevant telescope instrument parameters and environmental conditions. The spreadsheet is partly used for performance calculations and partly used to combine and integrate the output from several other sources. The spreadsheet model calculates the overall performance based on an Exposure Time Calculator using the Noise Equivalent Area metric (NEA). The NEA is further budgeted over 7 main High Level Requirements. The spreadsheet model is coupled to 1) a ZEMAX telescope optical model 2) a telescope FEM analysis to predict the optomechanical response under various gravity, temperature and wind load conditions, 3) a Matlab Simulink thermal model to predict the transient temperature behaviour of the most important telescope elements and 4) a Matlab Simulink control model to predict the

  7. Ultrasonic assisted synthesis of gem-dichloroaziridine derivatives using Mg/CCl4 under neutral conditions.

    Science.gov (United States)

    Rabiei, Khadijeh; Naeimi, Hossein

    2015-05-01

    A novel and convenient method for synthesis of gem-dichloroaziridine derivatives was reported in that was utilized Mg powder with CCl4 for dichlorocarbene generation under ultrasonic irradiation. In this clean and efficient reaction procedure, the desired products were purely obtained in excellent yields. The other advantages of this method are availability of reagents, very short reaction times, simplicity of the method, easily work up, neutral reaction medium and high purity of products. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. A 40 GByte/s read-out system for GEM

    International Nuclear Information System (INIS)

    Bowden, M.; Carrel, J.; Dorenbosch, J.; Kapoor, V.

    1994-04-01

    The preliminary design of the read-out system for the GEM (Gammas, Electrons, Muons) detector at the Superconducting Super Collider is presented. The system reads all digitized data from the detector data sources at a Level 1 trigger rate of up to 100 kHz. A total read-out bandwidth of 40 GBytes/s is available. Data are stored in buffers that are accessible for further event filtering by an on-line, processor farm. Data are transported to the farm only as they are needed by the higher-level trigger algorithms, leading to a reduced bandwidth requirement in the Data Acquisition System

  9. An Entrepreneurial Well-being Model based on GEM Data for Spain

    Directory of Open Access Journals (Sweden)

    José Manuel Sáiz-Álvarez

    2014-03-01

    Full Text Available The Economics of Happiness is one of the research areas of greatest growth in recent years. Throughout this work, a venture based model in which satisfaction of Spanish entrepreneurs with their professional life is performed. We analyze the responses of 9,989 entrepreneurs using data from the Global Entrepreneurship Monitor (GEM, and six hypothesis are discussed. The results show that, for the Spanish case, there is a strong consistency in the results the opportunity entrepreneurs present greater satisfaction than necessity entrepreneurs.

  10. Gas and Gas Pains

    Science.gov (United States)

    ... to produce gas. Often, relatively simple changes in eating habits can lessen bothersome gas. Certain digestive system disorders, ... such as soda and beer, increase stomach gas. Eating habits, such as eating too quickly, drinking through a ...

  11. GEM in the marine atmosphere and air-sea exchange of Hg during late autumn and winter cruise campaigns over the marginal seas of China

    Science.gov (United States)

    Wang, Yan; Liu, Ruhai; Li, Yanping; Cui, Xueqing; Zhou, Jianping; Liu, Shixuan; Zhang, Yuqing

    2017-07-01

    East Asia is one of the primary sources of atmospheric gaseous elemental mercury (GEM) among the world. In this study, GEM concentrations were measured during two cruises in late autumn and winter of 2012 and 2013 which passed through the marginal seas of China. The results show that the mean GEM concentration was 1.65 ng/m3 from the South China Sea to the Yellow Sea during the 2012 cruise. While the mean GEM concentration was 2.38 ng/m3 in the South Yellow Sea, and 1.75 ng/m3 in the North Yellow and Bohai Seas during the 2013 cruise. High GEM contents were detected when the steering wind was offshore. There is a significant positive relationship between GEM and air temperature for these two cruises. Low GEM content was presented when the cold northerly monsoon prevailed while air masses mainly came from the clean northern oceanic region. Dissolved gaseous mercury (DGM) concentration in the surface water of the south Yellow and Bohai seas were 74.4 ± 28 pg/L. DGM concentrations were correlated with water temperature (r = 0.244, p polluted air and low wind speed. High flux values were caused by the northerly monsoon which carried remote clean air to the sea, with large wind speeds. The northerly monsoon is an important factor affecting the GEM transport offshore to marginal sea and the cycle of mercury in the sea in late autumn and winter.

  12. Atmospheric gaseous elemental mercury (GEM concentrations and mercury depositions at a high-altitude mountain peak in south China

    Directory of Open Access Journals (Sweden)

    X. W. Fu

    2010-03-01

    Full Text Available China is regarded as the largest contributor of mercury (Hg to the global atmospheric Hg budget. However, concentration levels and depositions of atmospheric Hg in China are poorly known. Continuous measurements of atmospheric gaseous elemental mercury (GEM were carried out from May 2008 to May 2009 at the summit of Mt. Leigong in south China. Simultaneously, deposition fluxes of THg and MeHg in precipitation, throughfall and litterfall were also studied. Atmospheric GEM concentrations averaged 2.80±1.51 ng m−3, which was highly elevated compared to global background values but much lower than semi-rural and industrial/urban areas in China. Sources identification indicates that both regional industrial emissions and long range transport of Hg from central, south and southwest China were corresponded to the elevated GEM level. Seasonal and diurnal variations of GEM were observed, which reflected variations in source intensity, deposition processes and meteorological factors. Precipitation and throughfall deposition fluxes of THg and MeHg in Mt. Leigong were comparable or lower compared to those reported in Europe and North America, whereas litterfall deposition fluxes of THg and MeHg were higher compared to Europe and North America. This highlights the importance of vegetation to Hg atmospheric cycling. In th remote forest ecosystem of China, deposition of GEM via uptake of foliage followed by litterfall was very important for the depletion of atmospheric Hg. Elevated GEM level in ambient air may accelerate the foliar uptake of Hg through air which may partly explain the elevated litterfall deposition fluxes of Hg observed in Mt. Leigong.

  13. Gillespie eco-evolutionary models (GEMs) reveal the role of heritable trait variation in eco-evolutionary dynamics.

    Science.gov (United States)

    DeLong, John P; Gibert, Jean P

    2016-02-01

    Heritable trait variation is a central and necessary ingredient of evolution. Trait variation also directly affects ecological processes, generating a clear link between evolutionary and ecological dynamics. Despite the changes in variation that occur through selection, drift, mutation, and recombination, current eco-evolutionary models usually fail to track how variation changes through time. Moreover, eco-evolutionary models assume fitness functions for each trait and each ecological context, which often do not have empirical validation. We introduce a new type of model, Gillespie eco-evolutionary models (GEMs), that resolves these concerns by tracking distributions of traits through time as eco-evolutionary dynamics progress. This is done by allowing change to be driven by the direct fitness consequences of model parameters within the context of the underlying ecological model, without having to assume a particular fitness function. GEMs work by adding a trait distribution component to the standard Gillespie algorithm - an approach that models stochastic systems in nature that are typically approximated through ordinary differential equations. We illustrate GEMs with the Rosenzweig-MacArthur consumer-resource model. We show not only how heritable trait variation fuels trait evolution and influences eco-evolutionary dynamics, but also how the erosion of variation through time may hinder eco-evolutionary dynamics in the long run. GEMs can be developed for any parameter in any ordinary differential equation model and, furthermore, can enable modeling of multiple interacting traits at the same time. We expect GEMs will open the door to a new direction in eco-evolutionary and evolutionary modeling by removing long-standing modeling barriers, simplifying the link between traits, fitness, and dynamics, and expanding eco-evolutionary treatment of a greater diversity of ecological interactions. These factors make GEMs much more than a modeling advance, but an important

  14. Parametric nanomechanical amplification at very high frequency.

    Science.gov (United States)

    Karabalin, R B; Feng, X L; Roukes, M L

    2009-09-01

    Parametric resonance and amplification are important in both fundamental physics and technological applications. Here we report very high frequency (VHF) parametric resonators and mechanical-domain amplifiers based on nanoelectromechanical systems (NEMS). Compound mechanical nanostructures patterned by multilayer, top-down nanofabrication are read out by a novel scheme that parametrically modulates longitudinal stress in doubly clamped beam NEMS resonators. Parametric pumping and signal amplification are demonstrated for VHF resonators up to approximately 130 MHz and provide useful enhancement of both resonance signal amplitude and quality factor. We find that Joule heating and reduced thermal conductance in these nanostructures ultimately impose an upper limit to device performance. We develop a theoretical model to account for both the parametric response and nonequilibrium thermal transport in these composite nanostructures. The results closely conform to our experimental observations, elucidate the frequency and threshold-voltage scaling in parametric VHF NEMS resonators and sensors, and establish the ultimate sensitivity limits of this approach.

  15. Digital Microfluidics for Nucleic Acid Amplification

    Directory of Open Access Journals (Sweden)

    Beatriz Coelho

    2017-06-01

    Full Text Available Digital Microfluidics (DMF has emerged as a disruptive methodology for the control and manipulation of low volume droplets. In DMF, each droplet acts as a single reactor, which allows for extensive multiparallelization of biological and chemical reactions at a much smaller scale. DMF devices open entirely new and promising pathways for multiplex analysis and reaction occurring in a miniaturized format, thus allowing for healthcare decentralization from major laboratories to point-of-care with accurate, robust and inexpensive molecular diagnostics. Here, we shall focus on DMF platforms specifically designed for nucleic acid amplification, which is key for molecular diagnostics of several diseases and conditions, from pathogen identification to cancer mutations detection. Particular attention will be given to the device architecture, materials and nucleic acid amplification applications in validated settings.

  16. Digital Microfluidics for Nucleic Acid Amplification.

    Science.gov (United States)

    Coelho, Beatriz; Veigas, Bruno; Fortunato, Elvira; Martins, Rodrigo; Águas, Hugo; Igreja, Rui; Baptista, Pedro V

    2017-06-25

    Digital Microfluidics (DMF) has emerged as a disruptive methodology for the control and manipulation of low volume droplets. In DMF, each droplet acts as a single reactor, which allows for extensive multiparallelization of biological and chemical reactions at a much smaller scale. DMF devices open entirely new and promising pathways for multiplex analysis and reaction occurring in a miniaturized format, thus allowing for healthcare decentralization from major laboratories to point-of-care with accurate, robust and inexpensive molecular diagnostics. Here, we shall focus on DMF platforms specifically designed for nucleic acid amplification, which is key for molecular diagnostics of several diseases and conditions, from pathogen identification to cancer mutations detection. Particular attention will be given to the device architecture, materials and nucleic acid amplification applications in validated settings.

  17. Preventing PCR amplification carryover contamination in a clinical laboratory.

    Science.gov (United States)

    Aslanzadeh, Jaber

    2004-01-01

    During the past two decades PCR and several other DNA/RNA amplification techniques have become important diagnostic tools in clinical laboratories. Amplification products contamination has been the main impediment to using these techniques routinely in diagnostic laboratories. Over the years, several creative pre- and post-amplification methods have been developed that prevent amplicon carryover contamination. These procedures, coupled with automated systems that employ real-time amplification and simultaneous detection in a closed system, have substantially reduced the possibility of false positive results due to amplification products carryover contamination.

  18. Particle-in-cell Simulations of Raman Laser Amplification in Ionizing Plasmas

    International Nuclear Information System (INIS)

    Clark, Daniel S.; Fisch, Nathaniel J.

    2003-01-01

    By using the amplifying laser pulse in a plasma-based backward Raman laser amplifier to generate the plasma by photo-ionization of a gas simultaneous with the amplification process, possible instabilities of the pumping laser pulse can be avoided. Particle-in-cell simulations are used to study this amplification mechanism, and earlier results using more elementary models of the Raman interaction are verified [D.S. Clark and N.J. Fisch, Phys. Plasmas, 9 (6): 2772-2780, 2002]. The effects (unique to amplification in ionizing plasmas and not included in previous simulations) of blue-shifting of the pump and seed laser pulses and the generation of a wake are observed not significantly to impact the amplification process. As expected theoretically, the peak output intensity is found to be limited to I ∼ 10 17 W/cm 2 by forward Raman scattering of the amplifying seed. The integrity of the ionization front of the seed pulse against the development of a possible transverse modulation instability is also demonstrated

  19. Amplification of trace amounts of nucleic acids

    Science.gov (United States)

    Church, George M [Brookline, MA; Zhang, Kun [Brighton, MA

    2008-06-17

    Methods of reducing background during amplification of small amounts of nucleic acids employ careful analysis of sources of low level contamination. Ultraviolet light can be used to reduce nucleic acid contaminants in reagents and equipment. "Primer-dimer" background can be reduced by judicious design of primers. We have shown clean signal-to-noise with as little as starting material as one single human cell (.about.6 picogram), E. coli cell (.about.5 femtogram) or Prochlorococcus cell (.about.3 femtogram).

  20. Gem1 and ERMES Do Not Directly Affect Phosphatidylserine Transport from ER to Mitochondria or Mitochondrial Inheritance

    DEFF Research Database (Denmark)

    Nguyen, Tammy T; Lewandowska, Agnieszka; Choi, Jae-Yeon

    2012-01-01

    In yeast, a protein complex termed the ER-Mitochondria Encounter Structure (ERMES) tethers mitochondria to the endoplasmic reticulum. ERMES proteins are implicated in a variety of cellular functions including phospholipid synthesis, mitochondrial protein import, mitochondrial attachment to actin......, polarized mitochondrial movement into daughter cells during division, and maintenance of mitochondrial DNA (mtDNA). The mitochondrial-anchored Gem1 GTPase has been proposed to regulate ERMES functions. Here, we show that ERMES and Gem1 have no direct role in the transport of phosphatidylserine (PS) from...

  1. Development of entrepreneurship in Brazil based on indicators of the global entrepreneurship monitor (GEM

    Directory of Open Access Journals (Sweden)

    Ana Carolina Cozza Josende da Silva

    2015-06-01

    Full Text Available Entrepreneurship is very important in a society due to its influence with the growth and development of a country. The importance of studying and knowing the entrepreneurial activity and the entrepreneur's profile contributes positively to identify estimates of this activity and to clarify the future of this process. In this sense, this article presents the evolution of entrepreneurship in Brazil over the past 13 years, using for the study secondary data obtained from the GEM and IBGE researches, in which the search was conducted in documentary basis from 2001 to 2013. The results present a descriptive analysis of the Global Entrepreneurship Monitor entrepreneurship indicators (GEM concerning to the new entrepreneur rate and the rate of nascent entrepreneurs, growth of the Brazilian GDP related to entrepreneurship, entrepreneurship rate according to the entrepreneur stages (initial and established, initial entrepreneurs according to their motivation (by chance and necessity, by gender entrepreneurs, age, level of education. It was also carried out statistical analysis where the trend of the variables over time was verified by simple linear regression at the significance level of 5%. The study concludes that Brazil tends to present significant growth towards entrepreneurship, an advancement of the female contribution to the economy, increase of entrepreneurs because of more opportunities and stability in the existing businesses.

  2. First Results of the PixelGEM Central Tracking System for COMPASS

    CERN Document Server

    Austregesilo, Alexander; Ketzer, Bernhard; Konorov, Igor; Kramer, Markus; Mann, Alexander; Nagel, Thiemo; Paul, Stephan; Uhl, Sebastian

    2009-01-01

    For its physics program with a high-intensity hadron beam of up to 2e7 particles/s, the COMPASS experiment at CERN requires tracking of charged particles scattered by very small angles with respect to the incident beam direction. While good resolution in time and space is mandatory, the challenge is imposed by the high beam intensity, requiring radiation-hard detectors which add very little material to the beam path in order to minimize secondary interactions. To this end, a set of triple-GEM detectors with a hybrid readout structure consisting of pixels in the beam region and 2-D strips in the periphery was designed and built. Successful prototype tests proved the performance of this new detector type, showing both extraordinary high rate capability and detection efficiency. The amplitude information allowed to achieve spatial resolutions about a factor of 10 smaller than the pitch and a time resolution close to the theoretical limit imposed by the layout. The PixelGEM central tracking system consisting of f...

  3. The Shape of Long Outbursts in U Gem Type Dwarf Novae from AAVSO Data

    Science.gov (United States)

    Cannizzo, John K.

    2012-01-01

    We search the American Association of Variable Star Observers (AAVSO) archives of the two best studied dwarf novae in an attempt to find light curves for long out bursts that are extremely well-characterized. The systems are U Gem and S8 Cyg. Our goal is to search for embedded precursors such as those that have been found recently in the high fidelity Kepler data for superoutbursts of some members of the 8U UMa subclass of dwarf novae. For the vast majority of AAV80 data, the combination of low data cadence and large errors associated with individual measurements precludes one from making any strong statement about the shape of the long outbursts. However, for a small number of outbursts, extensive long term monitoring with digital photometry yields high fidelity light curves. We report the finding of embedded precursors in two of three candidate long outbursts. This reinforces van Paradijs' finding that long outbursts in dwarf novae above the period gap and superoutbursts in systems below the period gap constitute a unified class. The thermal-tidal instability to account for superoutbursts in the SU UMa stars predicts embedded precursors only for short orbital period dwarf novae, therefore the presence of embedded precursors in long orbital period systems - U Gem and SS Cyg - argues for a more general mechanism to explain long outbursts.

  4. Trace elemental analysis of Indian natural moonstone gems by PIXE and XRD techniques.

    Science.gov (United States)

    Venkateswara Rao, R; Venkateswarulu, P; Kasipathi, C; Sivajyothi, S

    2013-12-01

    A selected number of Indian Eastern Ghats natural moonstone gems were studied with a powerful nuclear analytical and non-destructive Proton Induced X-ray Emission (PIXE) technique. Thirteen elements, including V, Co, Ni, Zn, Ga, Ba and Pb, were identified in these moonstones and may be useful in interpreting the various geochemical conditions and the probable cause of their inceptions in the moonstone gemstone matrix. Furthermore, preliminary XRD studies of different moonstone patterns were performed. The PIXE technique is a powerful method for quickly determining the elemental concentration of a substance. A 3MeV proton beam was employed to excite the samples. The chemical constituents of moonstones from parts of the Eastern Ghats geological formations of Andhra Pradesh, India were determined, and gemological studies were performed on those gems. The crystal structure and the lattice parameters of the moonstones were estimated using X-Ray Diffraction studies, trace and minor elements were determined using the PIXE technique, and major compositional elements were confirmed by XRD. In the present work, the usefulness and versatility of the PIXE technique for research in geo-scientific methodology is established. © 2013 Elsevier Ltd. All rights reserved.

  5. Dependence of Crystal Quality and β Value on Synthesis Temperature in Growing Gem Diamond Crystals

    International Nuclear Information System (INIS)

    Hong-Yu, Xiao; Xiao-Peng, Jia; Shang-Sheng, Li; Yu, Tian; Ya-Fei, Zhang; Guo-Feng, Huang; Li-Qiu; Hong-An, Ma; Chuan-Yi, Zang

    2008-01-01

    High quality Ib gem diamond single crystals were synthesized in cubic anvil high-pressure apparatus (SPD-6 × 1200) under 5.4 GPa and 1230°C-1280°C. The (100) face of seed crystal was used as growth face, and Ni 70 Mn 25 Co 5 alloy was used as solvent/catalyst. The dependence of crystal quality and β value (the ratio of height to diameter of diamond crystal) on synthesis temperature was studied. When the synthesis temperature is between 1230°C and 1280°C, the β value of the synthetic high-quality gem diamond crystals is between 0.4 and 0.6. The results show that when the β value is between 0.4 and 0.45, the synthetic diamonds are sheet-shape crystals; however, when the β value is between 0.45 and 0.6, the synthetic diamonds are tower-shape crystals. In addition, when the β value is less than 0.4, skeleton crystals will appear. When the β value is more than 0.6, most of the synthetic diamond crystals are inferior crystals

  6. Performance studies of the P barANDA planar GEM-tracking detector in physics simulations

    Science.gov (United States)

    Divani Veis, Nazila; Firoozabadi, Mohammad M.; Karabowicz, Radoslaw; Maas, Frank; Saito, Takehiko R.; Voss, Bernd; ̅PANDA Gem-Tracker Subgroup

    2018-03-01

    The P barANDA experiment will be installed at the future facility for antiproton and ion research (FAIR) in Darmstadt, Germany, to study events from the annihilation of protons and antiprotons. The P barANDA detectors can cover a wide physics program about baryon spectroscopy and nucleon structure as well as the study of hadrons and hypernuclear physics including the study of excited hyperon states. One very specific feature of most hyperon ground states is the long decay length of several centimeters in the forward direction. The central tracking detectors of the P barANDA setup are not sufficiently optimized for these long decay lengths. Therefore, using a set of the planar GEM-tracking detectors in the forward region of interest can improve the results in the hyperon physics-benchmark channel. The current conceptual designed P barANDA GEM-tracking stations contribute the measurement of the particles emitted in the polar angles between about 2 to 22 degrees. For this designed detector performance and acceptance, studies have been performed using one of the important hyperonic decay channel p bar p → Λ bar Λ → p bar pπ+π- in physics simulations. The simulations were carried out using the PandaRoot software packages based on the FairRoot framework.

  7. Simulation and Digitization of a Gas Electron Multiplier Detector Using Geant4 and an Object-Oriented Digitization Program

    Science.gov (United States)

    McMullen, Timothy; Liyanage, Nilanga; Xiong, Weizhi; Zhao, Zhiwen

    2017-01-01

    Our research has focused on simulating the response of a Gas Electron Multiplier (GEM) detector using computational methods. GEM detectors provide a cost effective solution for radiation detection in high rate environments. A detailed simulation of GEM detector response to radiation is essential for the successful adaption of these detectors to different applications. Using Geant4 Monte Carlo (GEMC), a wrapper around Geant4 which has been successfully used to simulate the Solenoidal Large Intensity Device (SoLID) at Jefferson Lab, we are developing a simulation of a GEM chamber similar to the detectors currently used in our lab. We are also refining an object-oriented digitization program, which translates energy deposition information from GEMC into electronic readout which resembles the readout from our physical detectors. We have run the simulation with beta particles produced by the simulated decay of a 90Sr source, as well as with a simulated bremsstrahlung spectrum. Comparing the simulation data with real GEM data taken under similar conditions is used to refine the simulation parameters. Comparisons between results from the simulations and results from detector tests will be presented.

  8. Charged particle detection performance of gas electron multiplier detector for the upgrade of CMS endcap muon system at the CERN LHC

    CERN Document Server

    CMS Collaboration

    2015-01-01

    The CMS detector is one of two general-purpose detectors at the CERN LHC. LHC will provide exceptional high instantaneous and integrated luminosities after second long shutdown. The forward region $\\mid \\eta \\mid \\geq 1.5$ of the CMS detector will face extremely high particle rates in 10s of kHz/cm2 and hence it will affect the momentum resolution and longevity of the muon detectors. To overcome these issues, the CMS-GEM collaboration has proposed to install new large size high rate capable triple Gas Electron Multiplier (GEM) detectors in the forward region of CMS muon system. The proposal has been approved recently. The first set of Triple GEM detectors will be installed in the GE1/1 region ($1.6 < \\mid \\eta \\mid < 2.2$) of muon endcap during phase-II upgrade of the LHC. Towards this goal, full size CMS Triple GEM prototype chambers have been fabricated and put under the test beam at the CERN SPS test beam facility. The GEM detectors were operated with two gas mixtures: Ar:CO2 (70:30) and Ar:CO2:CF4 (...

  9. Antiproton beam profile measurements using Gas Electron Multipliers

    CERN Document Server

    Duarte Pinto, Serge; Spanggaard, Jens; Tranquille, Gerard

    2011-01-01

    The new beam profile measurement for the Antiproton Decelerator (AD) at CERN is based on a single Gas Electron Multiplier (GEM) with a 2D readout structure. This detector is very light, ~0.4% X_0, as required by the low energy of the antiprotons, 5.3 MeV. This overcomes the problems previously encountered with multi-wire proportional chambers (MWPC) for the same purpose, where beam interactions with the detector severely affect the obtained profiles. A prototype was installed and successfully tested in late 2010, with another five detectors now installed in the ASACUSA and AEgIS beam lines. We will provide a detailed description of the detector and discuss the results obtained. The success of these detectors in the AD makes GEM-based detectors likely candidates for upgrade of the beam profile monitors in all experimental areas at CERN. The various types of MWPC currently in use are aging and becoming increasingly difficult to maintain.

  10. Synthesis and applications of gem-bis-phosphonates, powerful complexing agents of metals; Synthese et applications de composes gem-bisphosphonates, de puissants complexants de metaux

    Energy Technology Data Exchange (ETDEWEB)

    Lecercle, D

    2007-12-15

    This thesis was devoted to the development of new ways to prepare gem-bis-phosphonates compounds (BPs), and was carried out under the Program of Nuclear and Environmental Toxicology (ToxNuc-E). Two applications of these compounds have been investigated, the preparation of potent ligands of the uranyl ion for a target of decorporation, and the preparation of new anticancer compounds. The first of these applications was the consequence of work done in the laboratory, that have shown the strong uranium-binding properties of bis-phosphonic ligands. The in vivo tests performed on these compounds have shown the tendency of these ligands to cause liver accumulation of uranium, we wanted to address this problem by modifying the method of anchoring of the bis-phosphonates functions. To this end we have developed a new way to access to these compounds using a metal-carbenoid mediated poly-ols and poly-amines insertion, the metal-carbenoid species bearing the bis-phosphonate function. Regarding the preparation of BPs as anticancer agents, we have developed a new synthetic pathway using a phosphine catalyzed {alpha}-P addition of phosphorated pro-nucleophiles to alkynyl-phosphonates as a key step. This enabled us to prepare thirty compound whose activity was evaluated on two cell lines (A431 and HuH7). Five of these compounds possess an activity equivalent to that of the compound described as the most active, the Zoledronate. (author)

  11. Progress on The GEMS (Gravity Electro-Magnetism-Strong) Theory of Field Unification and Its Application to Space Problems

    International Nuclear Information System (INIS)

    Brandenburg, J. E.

    2008-01-01

    Progress on the GEMS (Gravity Electro-Magnetism-Strong), theory is presented as well as its application to space problems. The GEMS theory is now validated through the Standard Model of physics. Derivation of the value of the Gravitation constant based on the observed variation of α with energy: results in the formula G congruent with (ℎ/2π)c/M ηc 2 exp(-1/(1.61α)), where α is the fine structure constant,(ℎ/2π), is Planck's constant, c, is the speed of light, and M ηc is the mass of the η cc Charmonium meson that is shown to be identical to that derived from the GEM postulates. Covariant formulation of the GEM theory is now possible through definition of the spacetime metric tensor as a portion of the EM stress tensor normalized by its own trace: g ab = 4(F c a F cb )/(F ab F ab ), it is found that this results in a massless ground state vacuum and a Newtonian gravitation potential φ = 1/2 E 2 /B 2 . It is also found that a Lorentz or flat-space metric is recovered in the limit of a full spectrum ZPF

  12. GEM-SELEKTOR Geochemical Modeling Package: TSolMod library and data interface for multicomponent phase models

    OpenAIRE

    Wagner T.; Kulik D. A.; Hingerl F. F.; Dmytrieva S. V.

    2012-01-01

    The development of highly accurate and computationally efficient modeling software based on Gibbs energy minimization (GEM) makes it possible to thermodynamically simulate geochemically realistic subsurface fluid rock interaction processes. This involves consideration of non ideal multicomponent multiphase systems that include dilute to concentrated aqueous electrolyte solutions mineral solid solutions supercritical fluids silicate and metal melts and sorption and ion exchange phases. Predict...

  13. GEnomes Management Application (GEM.app): a new software tool for large-scale collaborative genome analysis.

    Science.gov (United States)

    Gonzalez, Michael A; Lebrigio, Rafael F Acosta; Van Booven, Derek; Ulloa, Rick H; Powell, Eric; Speziani, Fiorella; Tekin, Mustafa; Schüle, Rebecca; Züchner, Stephan

    2013-06-01

    Novel genes are now identified at a rapid pace for many Mendelian disorders, and increasingly, for genetically complex phenotypes. However, new challenges have also become evident: (1) effectively managing larger exome and/or genome datasets, especially for smaller labs; (2) direct hands-on analysis and contextual interpretation of variant data in large genomic datasets; and (3) many small and medium-sized clinical and research-based investigative teams around the world are generating data that, if combined and shared, will significantly increase the opportunities for the entire community to identify new genes. To address these challenges, we have developed GEnomes Management Application (GEM.app), a software tool to annotate, manage, visualize, and analyze large genomic datasets (https://genomics.med.miami.edu/). GEM.app currently contains ∼1,600 whole exomes from 50 different phenotypes studied by 40 principal investigators from 15 different countries. The focus of GEM.app is on user-friendly analysis for nonbioinformaticians to make next-generation sequencing data directly accessible. Yet, GEM.app provides powerful and flexible filter options, including single family filtering, across family/phenotype queries, nested filtering, and evaluation of segregation in families. In addition, the system is fast, obtaining results within 4 sec across ∼1,200 exomes. We believe that this system will further enhance identification of genetic causes of human disease. © 2013 Wiley Periodicals, Inc.

  14. Girls in Engineering, Mathematics and Science, GEMS: A Science Outreach Program for Middle-School Female Students

    Science.gov (United States)

    Dubetz, Terry A.; Wilson, Jo Ann

    2013-01-01

    Girls in Engineering, Mathematics and Science (GEMS) is a science and math outreach program for middle-school female students. The program was developed to encourage interest in math and science in female students at an early age. Increased scientific familiarity may encourage girls to consider careers in science and mathematics and will also help…

  15. The splicing factor U1-70K interacts with the SMN complex and is required for nuclear gem integrity

    Czech Academy of Sciences Publication Activity Database

    Stejskalová, Eva; Staněk, David

    2014-01-01

    Roč. 127, č. 18 (2014), s. 3909-3915 ISSN 0021-9533 R&D Projects: GA ČR GAP302/11/1910 Institutional support: RVO:68378050 Keywords : nuclear gems * SMN * U1-70K Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 5.432, year: 2014

  16. The Germplasm Enhancement of Maize (GEM) project: A Public-Private Partnership (PPP) to increase genetic diversity in US maize

    Science.gov (United States)

    The Germplasm Enhancement of Maize (GEM) Project is a mission-oriented, cooperative research effort of the United States Department of Agriculture – Agricultural Research Service (USDA-ARS), land grant universities, private industry, and international agricultural research centers to broaden the ger...

  17. 3MeerLICHT and BlackGEM: custom-built telescopes to detect faint optical transients

    NARCIS (Netherlands)

    Bloemen, S. (Steven); Groot, P.J. (Paul J.); Woudt, P. (Patrick); Wolt, M.K. (Marc Klein); Mcbride, V. (Vanessa); Nelemans, G. (Gijs); Körding, E. (Elmar); Pretorius, M.L. (Magaretha L.); Roelfsema, R. (Ronald); Bettonvil, F. (Felix); Balster, H. (Harry); Bakker, R. (Roy); Dolron, P. (Peter); Van Elteren, A. (Arjen); Elswijk, E. (Eddy); Engels, A. (Arno); R.P. Fender; Fokker, M. (Marc); Haan, M. (Menno De); Hagoort, K. (Klaas); De Hoog, J. (Jasper); Horst, R.T. (Rik Ter); Van Der Kevie, G. (Giel); Lowski, S.L.K. (Stanis Law Koz); Kragt, J. (Jan); Lech, G. (Grzegorz); Le Poole, R. (Rudolf); Lesman, D. (Dirk); J. Morren (Johan); Navarro, R. (Ramon); Paalberends, W.-J. (Willem-Jelle); K.G. Paterson (Kerry); Laszek, R.P. (Rafal Paw); Pessemier, W. (Wim); Raskin, G. (Gert); Rutten, H. (Harrie); L.H.A. Scheers (Bart); Schuil, M. (Menno); Sybilski, P.W. (Piotr W.)

    2016-01-01

    textabstractWe present the MeerLICHT and BlackGEM telescopes, which are wide-field optical telescopes that are currently being built to study transient phenomena, gravitational wave counterparts and variable stars. The telescopes have 65 cm primary mirrors and a 2.7 square degree field-of-view. The

  18. Chloride ion-catalyzed generation of difluorocarbene for efficient preparation of gem-difluorinated cyclopropenes and cyclopropanes

    KAUST Repository

    Wang, Fei

    2011-01-01

    A chloride ion-catalyzed generation of difluorocarbene from a relatively non-toxic and inexpensive precursor, Me3SiCF2Cl (1), under mild and neutral conditions leads to an efficient preparation of gem-difluorocyclopropenes and difluorocyclopropanes through [2 + 1] cycloaddition reactions with alkynes and alkenes, respectively. © 2011 The Royal Society of Chemistry.

  19. Does the Arctic Amplification peak this decade?

    Science.gov (United States)

    Martin, Torge; Haine, Thomas W. N.

    2017-04-01

    Temperatures rise faster in the Arctic than on global average, a phenomenon known as Arctic Amplification. While this is well established from observations and model simulations, projections of future climate (here: RCP8.5) with models of the Coupled Model Intercomparison Project phase 5 (CMIP5) also indicate that the Arctic Amplification has a maximum. We show this by means of an Arctic Amplification factor (AAF), which we define as the ratio of Arctic mean to global mean surface air temperature (SAT) anomalies. The SAT anomalies are referenced to the period 1960-1980 and smoothed by a 30-year running mean. For October, the multi-model ensemble-mean AAF reaches a maximum in 2017. The maximum moves however to later years as Arctic winter progresses: for the autumn mean SAT (September to November) the maximum AAF is found in 2028 and for winter (December to February) in 2060. Arctic Amplification is driven, amongst others, by the ice-albedo feedback (IAF) as part of the more general surface albedo feedback (involving clouds, snow cover, vegetation changes) and temperature effects (Planck and lapse-rate feedbacks). We note that sea ice retreat and the associated warming of the summer Arctic Ocean are not only an integral part of the IAF but are also involved in the other drivers. In the CMIP5 simulations, the timing of the AAF maximum coincides with the period of fastest ice retreat for the respective month. Presence of at least some sea ice is crucial for the IAF to be effective because of the contrast in surface albedo between ice and open water and the need to turn ocean warming into ice melt. Once large areas of the Arctic Ocean are ice-free, the IAF should be less effective. We thus hypothesize that the ice retreat significantly affects AAF variability and forces a decline of its magnitude after at least half of the Arctic Ocean is ice-free and the ice cover becomes basically seasonal.

  20. Amplification Effects and Unconventional Monetary Policies

    Directory of Open Access Journals (Sweden)

    Cécile BASTIDON GILLES

    2012-02-01

    Full Text Available Global financial crises trigger off amplification effects, which allow relatively small shocks to propagate through the whole financial system. For this reason, the range of Central banks policies is now widening beyond conventional monetary policies and lending of last resort. The aim of this paper is to establish a rule for this practice. The model is based on the formalization of funding conditions in various types of markets. We conduct a comprehensive analysis of the “unconventional monetary policies”, and especially quantify government bonds purchases by the Central bank.

  1. Application of the GEM Inventory Data Capture Tools for Dynamic Vulnerability Assessment and Recovery Modelling

    Science.gov (United States)

    Verrucci, Enrica; Bevington, John; Vicini, Alessandro

    2014-05-01

    A set of open-source tools to create building exposure datasets for seismic risk assessment was developed from 2010-13 by the Inventory Data Capture Tools (IDCT) Risk Global Component of the Global Earthquake Model (GEM). The tools were designed to integrate data derived from remotely-sensed imagery, statistically-sampled in-situ field data of buildings to generate per-building and regional exposure data. A number of software tools were created to aid the development of these data, including mobile data capture tools for in-field structural assessment, and the Spatial Inventory Data Developer (SIDD) for creating "mapping schemes" - statistically-inferred distributions of building stock applied to areas of homogeneous urban land use. These tools were made publically available in January 2014. Exemplar implementations in Europe and Central Asia during the IDCT project highlighted several potential application areas beyond the original scope of the project. These are investigated here. We describe and demonstrate how the GEM-IDCT suite can be used extensively within the framework proposed by the EC-FP7 project SENSUM (Framework to integrate Space-based and in-situ sENSing for dynamic vUlnerability and recovery Monitoring). Specifically, applications in the areas of 1) dynamic vulnerability assessment (pre-event), and 2) recovery monitoring and evaluation (post-event) are discussed. Strategies for using the IDC Tools for these purposes are discussed. The results demonstrate the benefits of using advanced technology tools for data capture, especially in a systematic fashion using the taxonomic standards set by GEM. Originally designed for seismic risk assessment, it is clear the IDCT tools have relevance for multi-hazard risk assessment. When combined with a suitable sampling framework and applied to multi-temporal recovery monitoring, data generated from the tools can reveal spatio-temporal patterns in the quality of recovery activities and resilience trends can be

  2. Natural gas; Gas Natural

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Carlos A.; Moraes, Claudia C.D. [Eletricidade de Sao Paulo S.A. (ELETROPAULO), Sao Paulo, SP (Brazil); Fonseca, Carlos H.F. [Centrais Eletricas de Santa Catarina S.A., Florianopolis, SC (Brazil); Silva, Clecio Fabricio da; Alves, Ricardo P. [Companhia Paranaense de Energia (COPEL), Curitiba, PR (Brazil); Sposito, Edivaldo Soares; Hulle, Lutero [Espirito Santo Centrais Eletricas S.A. (ESCELSA), Vitoria, ES (Brazil); S. Martins, Icaro da [Centrais Eletricas do Norte do Brasil S.A. (ELETRONORTE), Belem, PA (Brazil); Vilhena, Joao Luiz S. de [Companhia Energetica de Minas Gerais (CEMIG), Belo Horizonte, MG (Brazil); Fagundes, Zaluar Aquino [Companhia Estadual de Energia Eletrica do Estado do Rio Grande do Sul, Porto Alegre, RS (Brazil)

    1996-12-31

    An increase in the consumption of natural gas in Brazil is an expected fact in what concerns energetic planning. This work presents the existing situation in what concerns natural gas utilization in the main world economies, as well as an analysis of the participation of this fuel among the energy final consumption per sources. The Brazilian consumption of natural gas is also analysed as well as the international agreement between Brazil and Bolivia for natural gas commercialization. Some legal, institutional and political aspects related to natural gas commercialization are also discussed. Finally, several benefits to be brought by the utilization of natural gas are presented 10 refs., 3 tabs.

  3. Parametric amplification in MoS2drum resonator.

    Science.gov (United States)

    Prasad, Parmeshwar; Arora, Nishta; Naik, A K

    2017-11-30

    Parametric amplification is widely used in diverse areas from optics to electronic circuits to enhance low level signals by varying relevant system parameters. Parametric amplification has also been performed in several micro-nano resonators including nano-electromechanical system (NEMS) resonators based on a two-dimensional (2D) material. Here, we report the enhancement of mechanical response in a MoS 2 drum resonator using degenerate parametric amplification. We use parametric pumping to modulate the spring constant of the MoS 2 resonator and achieve a 10 dB amplitude gain. We also demonstrate quality factor enhancement in the resonator with parametric amplification. We investigate the effect of cubic nonlinearity on parametric amplification and show that it limits the gain of the mechanical resonator. Amplifying ultra-small displacements at room temperature and understanding the limitations of the amplification in these devices is key for using these devices for practical applications.

  4. Gas and Gas Pains

    Science.gov (United States)

    ... Gas and gas pains Symptoms & causes Diagnosis & treatment Advertisement Mayo Clinic does not endorse companies or products. ... a Job Site Map About This Site Twitter Facebook Google YouTube Pinterest Mayo Clinic is a not- ...

  5. Space Optical Communications Using Laser Beam Amplification

    Science.gov (United States)

    Agrawal, Govind

    2015-01-01

    The Space Optical Communications Using Laser Beam Amplification (SOCLBA) project will provide a capability to amplify a laser beam that is received in a modulating retro-reflector (MRR) located in a satellite in low Earth orbit. It will also improve the pointing procedure between Earth and spacecraft terminals. The technology uses laser arrays to strengthen the reflected laser beam from the spacecraft. The results of first year's work (2014) show amplification factors of 60 times the power of the signal beam. MMRs are mirrors that reflect light beams back to the source. In space optical communications, a high-powered laser interrogator beam is directed from the ground to a satellite. Within the satellite, the beam is redirected back to ground using the MMR. In the MMR, the beam passes through modulators, which encode a data signal onto the returning beam. MMRs can be used in small spacecraft for optical communications. The SOCLBA project is significant to NASA and small spacecraft due to its application to CubeSats for optical data transmission to ground stations, as well as possible application to spacecraft for optical data transmission.

  6. Primordial magnetic field amplification from turbulent reheating

    International Nuclear Information System (INIS)

    Calzetta, Esteban; Kandus, Alejandra

    2010-01-01

    We analyze the possibility of primordial magnetic field amplification by a stochastic large scale kinematic dynamo during reheating. We consider a charged scalar field minimally coupled to gravity. During inflation this field is assumed to be in its vacuum state. At the transition to reheating the state of the field changes to a many particle/anti-particle state. We characterize that state as a fluid flow of zero mean velocity but with a stochastic velocity field. We compute the scale-dependent Reynolds number Re(k), and the characteristic times for decay of turbulence, t d and pair annihilation t a , finding t a d . We calculate the rms value of the kinetic helicity of the flow over a scale L and show that it does not vanish. We use this result to estimate the amplification factor of a seed field from the stochastic kinematic dynamo equations. Although this effect is weak, it shows that the evolution of the cosmic magnetic field from reheating to galaxy formation may well be more complex than as dictated by simple flux freezing

  7. Electronic cyclotron radiation amplification in thermonuclear plasmas

    International Nuclear Information System (INIS)

    Ziebell, L.F.

    1983-01-01

    The amplified emission of electron cyclotron radiation near the fundamental frequency from an inhomogeneous, anisotropic plasma slab is investigated in a linear theory. Plasma polarization effects are consistently included. Expressions are developed in the WKB approximation for emission in the ordinary and the extraordinary modes, for propagation perpendicular to the magnetic field. Numerical results are given for the extraordinary mode, for which effects are strongest. For the case of a loss-cone-type electron momentum distribution, it is shown that the amplification is sensitively dependent on the ratio of parallel-to-perpendicular temperature and on inhomogeneities in the magnetic field. The dependence of the amplification on the distribution is further investigated by considering superpositions of loss-cone and Maxwellian components. It is show that the presence of a Maxwellian component in general reduces the emission relative to the pure loss-cone case, and situations occur in which a layer in the slab very effectively absorbs all the radiation amplified elsewhere. A peculiar behaviour of the refractive index, which occurs in the transition from the pure loss-cone to the pure Maxwellian case, is discussed. (author)

  8. Two-dimensional GEM imaging detector with delay-line readout

    Science.gov (United States)

    Guedes, G. P.; Breskin, A.; Chechik, R.; Vartsky, D.; Bar, D.; Barbosa, A. F.; Marinho, P. R. B.

    2003-11-01

    A 100×100 mm 2 2D imaging detector, based on a triple-GEM gaseous multiplier, striped x- y readout anode and discrete delay-line readout, is presented. The fast (2.1 ns tap -1) delay-line circuit was designed to match the anode-charge signal profile, namely its rise-time and length. The detector's imaging capability was systematically studied in Ar/CO 2 (70/30) with 5.9 keV X-rays; x- y resolution of σ=0.05 and 0.1 mm for top and bottom anode strips, respectively, and integral non-linearity of ˜0.15% are demonstrated.

  9. The optimisation of a water distribution system using Bentley WaterGEMS software

    Directory of Open Access Journals (Sweden)

    Świtnicka Karolina

    2017-01-01

    Full Text Available The proper maintenance of water distribution systems (WDSs requires from operators multiple actions in order to ensure optimal functioning. Usually, all requirements should be adjusted simultaneously. Therefore, the decision-making process is often supported by multi-criteria optimisation methods. Significant improvements of exploitation conditions of WDSs functioning can be achieved by connecting small water supply networks into group systems. Among many potential tools supporting advanced maintenance and management of WDSs, significant improvements have tools that can find the optimal solution by the implemented mechanism of metaheuristic methods, such as the genetic algorithm. In this paper, an exemplary WDS functioning optimisation is presented, in relevance to a group water supply system. The action range of optimised parameters included: maximisation of water flow velocity, regulation of pressure head, minimisation of water retention time in a network (water age and minimisation of pump energy consumption. All simulations were performed in Bentley WaterGEMS software.

  10. C-4 Gem-Dimethylated Oleanes of Gymnema sylvestre and Their Pharmacological Activities

    Directory of Open Access Journals (Sweden)

    Giovanni Di Fabio

    2013-12-01

    Full Text Available Gymnema sylvestre R. Br., one of the most important medicinal plants of the Asclepiadaceae family, is a herb distributed throughout the World, predominantly in tropical countries. The plant, widely used for the treatment of diabetes and as a diuretic in Indian proprietary medicines, possesses beneficial digestive, anti-inflammatory, hypoglycemic and anti-helmentic effects. Furthermore, it is believed to be useful in the treatment of dyspepsia, constipation, jaundice, hemorrhoids, cardiopathy, asthma, bronchitis and leucoderma. A literature survey revealed that some other notable pharmacological activities of the plant such as anti-obesity, hypolipidemic, antimicrobial, free radical scavenging and anti-inflammatory properties have been proven too. This paper aims to summarize the chemical and pharmacological reports on a large group of C-4 gem-dimethylated pentacyclic triterpenoids from Gymnema sylvestre.

  11. A New GEM-like Imaging Detector with Electrodes Coated with Resistive Layers

    CERN Document Server

    Di Mauro, Antonio; Martinengo, Paolo; Napri, Eugenio; Peskov, Vladimir; Periale, Luciano; Picchi, P.; Pietropaolo, Francesco; Rodionov, I.

    We have developed and tested several prototypes of GEM-like detectors with electrodes coated with resistive layers: CuO or CrO. These detectors can operate stably at gains close to 10E5 and they are very robust. We discovered that the cathodes of these detectors could be coated by CsI layers and in such a way the detectors gain high efficiency for the UV photons. We also demonstrated that such detectors can operate stably in the cascade mode and high overall gains (~10E6) are reachable. This opens applications in several areas, for example in RICH or in noble liquid TPCs. Results from the first applications of these devices for UV photon detection at room and cryogenic temperatures are given.

  12. 3D field calculation of the GEM prototype magnet and comparison with measurements

    Energy Technology Data Exchange (ETDEWEB)

    Lari, R.J.

    1983-10-28

    The proposed 4 GeV Electron Microtron (GEM) is designed to fill the existing buildings left vacant by the demise of the Zero Gradient Synchrotron (ZGS) accelerator. One of the six large dipole magnets is shown as well as the first 10 electron orbits. A 3-orbit prototype magnet has been built. The stepped edge of the magnet is to keep the beam exiting perpendicular to the pole. The end guards that wrap around the main coils are joined together by the 3 shield plates. The auxiliary coils are needed to keep the end guards and shield plates from saturating. A 0.3 cm Purcell filter air gap exists between the pole and the yoke. Can anyone question this being a truly three-dimensional magnetostatic problem. The computer program TOSCA, developed at the Rutherford Appleton Laboratory by the Computing Applications Group, was used to calculate this magnet and the results have been compared with measurements.

  13. Analysis of data recorded by the LCTPC equipped with a two layer GEM-system

    CERN Document Server

    Ljunggren, M

    2012-01-01

    wire based readout. The prototype TPC is placed in a 1 Tesla magnet at DESY and tested using an electron beam. Analyses of data taken during two different measurement series, in 2009 and 2010, are presented here. The TPC was instrumented with a two layer GEM system and read out using modified electronics from the ALICE experiment, including the programmable charge sensitive preamp-shaper PCA16. The PCA16 chip has a number of programmable parameters which allows studies to determine the settings optimal to the final TPC. Here, the impact of the shaping time on the space resolution in the drift direction was studied. It was found that a shaping time of 60 ns is the b...

  14. Estimating Fallout Building Attributes from Architectural Features and Global Earthquake Model (GEM) Building Descriptions

    Energy Technology Data Exchange (ETDEWEB)

    Dillon, Michael B. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Kane, Staci R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-03-01

    A nuclear explosion has the potential to injure or kill tens to hundreds of thousands (or more) of people through exposure to fallout (external gamma) radiation. Existing buildings can protect their occupants (reducing fallout radiation exposures) by placing material and distance between fallout particles and individuals indoors. Prior efforts have determined an initial set of building attributes suitable to reasonably assess a given building’s protection against fallout radiation. The current work provides methods to determine the quantitative values for these attributes from (a) common architectural features and data and (b) buildings described using the Global Earthquake Model (GEM) taxonomy. These methods will be used to improve estimates of fallout protection for operational US Department of Defense (DoD) and US Department of Energy (DOE) consequence assessment models.

  15. Gasoline, Ethanol and Methanol (GEM) Ternary Blends utilization as an Alternative to Conventional Iraqi Gasoline to Suppress Emitted Sulfur and Lead Components to Environment

    OpenAIRE

    Miqdam Tariq Chaichan

    2016-01-01

    Iraqi conventional gasoline characterized by its low octane number not exceed 82 and high lead and sulfur content. In this paper tri-component or ternary, blends of gasoline, ethanol, and methanol presented as an alternative fuel for Iraqi conventional gasoline. The study conducted by using GEM blend that equals E85 blend in octane rating. The used GEM selected from Turner, 2010 collection. G37 E20 M43 (37% gasoline + 20% ethanol+ 43% methanol) was chosen as GEM in present study. This blend u...

  16. Earthquake acceleration amplification based on single microtremor test

    Science.gov (United States)

    Jaya Syahbana, Arifan; Kurniawan, Rahmat; Soebowo, Eko

    2018-02-01

    Understanding soil dynamics is needed to understand soil behaviour, including the parameters of earthquake acceleration amplification. Many researchers now conduct single microtremor tests to obtain amplification of velocity and natural periods of soil at test sites. However, these amplification parameters are rarely used, so a method is needed to convert the velocity amplification to acceleration amplification. This paper will discuss the proposed process of changing the value of amplification. The proposed method is to integrate the time histories of the synthetic earthquake acceleration of the soil surface under the deaggregation at that location so the time histories of the velocity earthquake will be obtained. Next is to conduct a “fitting curve” between amplification by a single microtremor test with amplification of the synthetic earthquake velocity time histories. After obtaining the fitting curve time histories of velocity, differentiation will be conducted to obtain fitting curve acceleration time histories. The final step after obtaining the fitting curve is to compare the acceleration of the “fitting curve” against the histories time of the acceleration of synthetic earthquake at bedrocks to obtain single microtremor acceleration amplification factor.

  17. Improved PCR Amplification of Broad Spectrum GC DNA Templates.

    Science.gov (United States)

    Guido, Nicholas; Starostina, Elena; Leake, Devin; Saaem, Ishtiaq

    2016-01-01

    Many applications in molecular biology can benefit from improved PCR amplification of DNA segments containing a wide range of GC content. Conventional PCR amplification of DNA sequences with regions of GC less than 30%, or higher than 70%, is complex due to secondary structures that block the DNA polymerase as well as mispriming and mis-annealing of the DNA. This complexity will often generate incomplete or nonspecific products that hamper downstream applications. In this study, we address multiplexed PCR amplification of DNA segments containing a wide range of GC content. In order to mitigate amplification complications due to high or low GC regions, we tested a combination of different PCR cycling conditions and chemical additives. To assess the fate of specific oligonucleotide (oligo) species with varying GC content in a multiplexed PCR, we developed a novel method of sequence analysis. Here we show that subcycling during the amplification process significantly improved amplification of short template pools (~200 bp), particularly when the template contained a low percent of GC. Furthermore, the combination of subcycling and 7-deaza-dGTP achieved efficient amplification of short templates ranging from 10-90% GC composition. Moreover, we found that 7-deaza-dGTP improved the amplification of longer products (~1000 bp). These methods provide an updated approach for PCR amplification of DNA segments containing a broad range of GC content.

  18. C-MET overexpression and amplification in gliomas.

    Science.gov (United States)

    Kwak, Yoonjin; Kim, Seong-Ik; Park, Chul-Kee; Paek, Sun Ha; Lee, Soon-Tae; Park, Sung-Hye

    2015-01-01

    We investigated c-Met overexpression and MET gene amplification in gliomas to determine their incidence and prognostic significance. c-Met immunohistochemistry and MET gene fluorescence in situ hybridization were carried out on tissue microarrays from 250 patients with gliomas (137 grade IV GBMs and 113 grade II and III diffuse gliomas). Clinicopathological features of these cases were reviewed. c-Met overexpression and MET gene amplification were detected in 13.1% and 5.1% of the GBMs, respectively. All the MET-amplified cases showed c-Met overexpression, but MET amplification was not always concordant with c-Met overexpression. None of grade II and III gliomas demonstrated c-Met overexpression or MET gene amplification. Mean survival of the GBM patients with MET amplification was not significantly different from patients without MET amplification (P=0.155). However, GBM patients with c-Met overexpression survived longer than patients without c-Met overexpression (P=0.035). Although MET amplification was not related to poor GBM prognosis, it is partially associated with the aggressiveness of gliomas, as MET amplification was found only in grade IV, not in grade II and III gliomas. We suggest that MET inhibitor therapy may be beneficial in about 5% GBMs, which was the incidence of MET gene amplification found in the patients included in this study.

  19. Ginkgo biloba and risk of cancer: secondary analysis of the Ginkgo Evaluation of Memory (GEM) Study.

    Science.gov (United States)

    Biggs, Mary L; Sorkin, Barbara C; Nahin, Richard L; Kuller, Lewis H; Fitzpatrick, Annette L

    2010-07-01

    Evidence from in vitro and in vivo studies suggests that Ginkgo biloba has cancer chemopreventive properties, but epidemiological evidence is sparse. We analyzed cancer as a secondary endpoint in the Ginkgo Evaluation of Memory (GEM) Study, the largest randomized, double-blind, placebo-controlled clinical trial of Ginkgo supplementation to date. A total of 3069 GEM participants 75+ years of age were randomized to twice-daily doses of either 120 mg Ginkgo extract (EGb 761) or placebo and followed for a median 6.1 years. We identified hospitalizations for invasive cancer by reviewing hospital admission and discharge records for all reported hospitalizations over follow-up. Using an intention-to-treat approach, we compared the risk of cancer hospitalization between participants assigned to treatment and those assigned to placebo. During the intervention, there were 148 cancer hospitalizations in the placebo group and 162 in the EGb 761 group (Hazard ratio (HR), 1.09; 95% confidence interval (CI), 0.87-1.36; p = 0.46). Among the site-specific cancers analyzed, we observed an increased risk of breast (HR, 2.15; 95%CI, 0.97-4.80; p = 0.06) and colorectal (HR, 1.62; 95%CI, 0.92-2.87; p = 0.10) cancer, and a reduced risk of prostate cancer (HR, 0.71; 95%CI, 0.43-1.17; p = 0.18). Overall, these results do not support the hypothesis that regular use of Ginkgo biloba reduces the risk of cancer. (c) 2010 John Wiley & Sons, Ltd.

  20. Dst Index in the 2008 GEM Modeling Challenge - Model Performance for Moderate and Strong Magnetic Storms

    Science.gov (United States)

    Rastaetter, Lutz; Kuznetsova, Maria; Hesse, Michael; Chulaki, Anna; Pulkkinen, Antti; Ridley, Aaron J.; Gombosi, Tamas; Vapirev, Alexander; Raeder, Joachim; Wiltberger, Michael James; hide

    2010-01-01

    The GEM 2008 modeling challenge efforts are expanding beyond comparing in-situ measurements in the magnetosphere and ionosphere to include the computation of indices to be compared. The Dst index measures the largest deviations of the horizontal magnetic field at 4 equatorial magnetometers from the quiet-time background field and is commonly used to track the strength of the magnetic disturbance of the magnetosphere during storms. Models can calculate a proxy Dst index in various ways, including using the Dessler-Parker Sckopke relation and the energy of the ring current and Biot-Savart integration of electric currents in the magnetosphere. The GEM modeling challenge investigates 4 space weather events and we compare models available at CCMC against each other and the observed values of Ost. Models used include SWMF/BATSRUS, OpenGGCM, LFM, GUMICS (3D magnetosphere MHD models), Fok-RC, CRCM, RAM-SCB (kinetic drift models of the ring current), WINDMI (magnetosphere-ionosphere electric circuit model), and predictions based on an impulse response function (IRF) model and analytic coupling functions with inputs of solar wind data. In addition to the analysis of model-observation comparisons we look at the way Dst is computed in global magnetosphere models. The default value of Dst computed by the SWMF model is for Bz the Earth's center. In addition to this, we present results obtained at different locations on the Earth's surface. We choose equatorial locations at local noon, dusk (18:00 hours), midnight and dawn (6:00 hours). The different virtual observatory locations reveal the variation around the earth-centered Dst value resulting from the distribution of electric currents in the magnetosphere during different phases of a storm.

  1. Ozone observations over the UAE and their analysis with GEM-AQ model

    Science.gov (United States)

    Majeed, Tariq; Kaminski, Jacek; Iqbal, Mazhar; Abbasi, Naveed; Lootah, Nadia; Struzewska, Joanna; Durka, Pawel

    A study of ozone climatology in the UAE began in 2006 with a couple of ozone sounding experiments to the measure the vertical profiles of ozone and their analysis by using the Global Environmental Multiscale - Air Quality (GEM-AQ) model. The purpose of this study was to gain insight into the chemical and dynamical structures in the atmosphere of this unique subtropical location (latitude 24.45N; longitude 54.22E). Ozone sounding with balloon-borne ECC ozonesonde has been continued since 2006. In this paper, we present ozone profiles throughout the troposphere and the stratosphere characterizing the wet (January - April) and dry (May - August) seasons of 2013 over the UAE. Preliminary results of wet season profiles indicate that the stratospheric ozone is quite stable while thick polluted layers confined to the lower tropospheric heights, showing enhancements in ozone contents. The amount of tropospheric ozone which is transported from the stratosphere by dynamical processes, although not well known, shows considerable variation both geographically and seasonally. Excessive values of ozone mixing ratios in the range 50 - 55 ppb near the ground are observed. These values are 20 to 30% larger than those observed at nearby sounding stations like New Delhi (India) and Esfahan (Iran) using the same technique. The surface ozone in the dry season is observed to be even larger compared to the wet season exceeding 100 ppb on occasions. The difference in these values probably reflects the elevated levels of air pollution due to petrochemicals and automobile emissions in the UAE. We will present ECC sounding data and GEM-AQ results including a discussion on the high levels of surface ozone responsible for contaminating the air quality in the UAE. This work is supported by National Research Foundation, UAE.

  2. Gadget for epilithic microalgal sampling (GEMS Dispositivo para amostragem de microalgas epilíticas

    Directory of Open Access Journals (Sweden)

    LGC. Canani

    2010-05-01

    Full Text Available Benthic microalgae sampling in lotic systems is carried out using either artificial or natural substrate. Natural substrate is more suitable for biomass and productivity estimates as well as biodiversity assessment because it contains the communities that are typical of the environment. We present a new gadget for epilithic microalgae sampling (GEMS that allows sampling in situ when it is impossible to remove the substrate from the river bed. The sampler consists of an acrylic box with a 25 cm diameter opening on its base that allows access to the substrate. This gadget can be used in shallow plan bedrock streams and it keeps the sample area isolated as much as possible minimising losses and contamination. It is also easy to construct and handle.As amostragens de microalgas bênticas em sistemas lóticos são realizadas através do uso de substrato natural ou artificial. Substratos naturais são mais adequados para a estimativa de biomassa e produtividade, assim como, para a avaliação de biodiversidade, porque eles contêm as comunidades que são típicas de um determinado ambiente. Nós apresentamos um novo dispositivo para amostragem de microalgas epilíticas (GEMS que permite a amostragem in situ, quando é impossível remover o substrato do leito do rio. O amostrador consiste em uma caixa de acrílico com uma abertura de 25 cm de diâmetro em sua base que permite acesso ao substrato. O amostrador pode ser usado em riachos rasos e de leito rochoso e plano, e mantém a área amostral o mais isolada possível, minimizando perdas e contaminação, além de ser fácil de construir e manusear.

  3. Raman amplification in optical communication systems

    DEFF Research Database (Denmark)

    Kjær, Rasmus

    2008-01-01

    Fiber Raman amplifiers are investigated with the purpose of identifying new applications and limitations for their use in optical communication systems. Three main topics are investigated, namely: New applications of dispersion compensating Raman amplifiers, the use Raman amplification to increase...... støjtal under 4,5 dB og en samlet udgangseffekt på 22 dBm. Med henblik på at forlænge rækkevidden af fremtidige access-netværk foreslås en ny arkitektur for såkaldte langdistance passive optiske netværk (PON). Dette system evalueres både teoretisk og eksperimentelt. Distribueret Raman-forstærkning bruges...

  4. Parametric Amplification of a Superconducting Plasma Wave.

    Science.gov (United States)

    Rajasekaran, S; Casandruc, E; Laplace, Y; Nicoletti, D; Gu, G D; Clark, S R; Jaksch, D; Cavalleri, A

    2016-11-01

    Many applications in photonics require all-optical manipulation of plasma waves1, which can concentrate electromagnetic energy on sub-wavelength length scales. This is difficult in metallic plasmas because of their small optical nonlinearities. Some layered superconductors support Josephson plasma waves (JPWs)2,3, involving oscillatory tunneling of the superfluid between capacitively coupled planes. Josephson plasma waves are also highly nonlinear4, and exhibit striking phenomena like cooperative emission of coherent terahertz radiation5,6, superconductor-metal oscillations7 and soliton formation8. We show here that terahertz JPWs can be parametrically amplified through the cubic tunneling nonlinearity in a cuprate superconductor. Parametric amplification is sensitive to the relative phase between pump and seed waves and may be optimized to achieve squeezing of the order parameter phase fluctuations9 or single terahertz-photon devices.

  5. Parametric amplification by coupled flux qubits

    Energy Technology Data Exchange (ETDEWEB)

    Rehák, M.; Neilinger, P.; Grajcar, M. [Department of Experimental Physics, Comenius University, SK-84248 Bratislava (Slovakia); Institute of Physics, Slovak Academy of Science, 845 11 Bratislava (Slovakia); Oelsner, G.; Hübner, U.; Meyer, H.-G. [Leibniz Institute of Photonic Technology, P.O. Box 100239, D-07702 Jena (Germany); Il' ichev, E. [Leibniz Institute of Photonic Technology, P.O. Box 100239, D-07702 Jena (Germany); Novosibirsk State Technical University, 20 K. Marx Ave., 630092 Novosibirsk (Russian Federation)

    2014-04-21

    We report parametric amplification of a microwave signal in a Kerr medium formed from superconducting qubits. Two mutually coupled flux qubits, embedded in the current antinode of a superconducting coplanar waveguide resonator, are used as a nonlinear element. Shared Josephson junctions provide the qubit-resonator coupling, resulting in a device with a tunable Kerr constant (up to 3 × 10{sup −3}) and a measured gain of about 20 dB. This arrangement represents a unit cell which can be straightforwardly extended to a quasi one-dimensional quantum metamaterial with large tunable Kerr nonlinearity, providing a basis for implementation of wide-band travelling wave parametric amplifiers.

  6. Heralded amplification of path entangled quantum states

    Science.gov (United States)

    Monteiro, F.; Verbanis, E.; Caprara Vivoli, V.; Martin, A.; Gisin, N.; Zbinden, H.; Thew, R. T.

    2017-06-01

    Device-independent quantum key distribution (DI-QKD) represents one of the most fascinating challenges in quantum communication, exploiting concepts of fundamental physics, namely Bell tests of nonlocality, to ensure the security of a communication link. This requires the loophole-free violation of a Bell inequality, which is intrinsically difficult due to losses in fibre optic transmission channels. Heralded photon amplification (HPA) is a teleportation-based protocol that has been proposed as a means to overcome transmission loss for DI-QKD. Here we demonstrate HPA for path entangled states and characterise the entanglement before and after loss by exploiting a recently developed displacement-based detection scheme. We demonstrate that by exploiting HPA we are able to reliably maintain high fidelity entangled states over loss-equivalent distances of more than 50 km.

  7. Introduction to quantum noise, measurement, and amplification

    Science.gov (United States)

    Clerk, A. A.; Devoret, M. H.; Girvin, S. M.; Marquardt, Florian; Schoelkopf, R. J.

    2010-04-01

    The topic of quantum noise has become extremely timely due to the rise of quantum information physics and the resulting interchange of ideas between the condensed matter and atomic, molecular, optical-quantum optics communities. This review gives a pedagogical introduction to the physics of quantum noise and its connections to quantum measurement and quantum amplification. After introducing quantum noise spectra and methods for their detection, the basics of weak continuous measurements are described. Particular attention is given to the treatment of the standard quantum limit on linear amplifiers and position detectors within a general linear-response framework. This approach is shown how it relates to the standard Haus-Caves quantum limit for a bosonic amplifier known in quantum optics and its application to the case of electrical circuits is illustrated, including mesoscopic detectors and resonant cavity detectors.

  8. Controlled Microwave Heating Accelerates Rolling Circle Amplification.

    Science.gov (United States)

    Yoshimura, Takeo; Suzuki, Takamasa; Mineki, Shigeru; Ohuchi, Shokichi

    2015-01-01

    Rolling circle amplification (RCA) generates single-stranded DNAs or RNA, and the diverse applications of this isothermal technique range from the sensitive detection of nucleic acids to analysis of single nucleotide polymorphisms. Microwave chemistry is widely applied to increase reaction rate as well as product yield and purity. The objectives of the present research were to apply microwave heating to RCA and indicate factors that contribute to the microwave selective heating effect. The microwave reaction temperature was strictly controlled using a microwave applicator optimized for enzymatic-scale reactions. Here, we showed that microwave-assisted RCA reactions catalyzed by either of the four thermostable DNA polymerases were accelerated over 4-folds compared with conventional RCA. Furthermore, the temperatures of the individual buffer components were specifically influenced by microwave heating. We concluded that microwave heating accelerated isothermal RCA of DNA because of the differential heating mechanisms of microwaves on the temperatures of reaction components, although the overall reaction temperatures were the same.

  9. Social and political amplification of technological hazards

    International Nuclear Information System (INIS)

    Ibitayo, Olurominiyi O.; Mushkatel, Alvin; Pijawka, K. David

    2004-01-01

    Using an industrial explosion in Henderson, Nevada, as a case study, this paper examines three main issues: the efficacy of a technological hazard event in amplifying otherwise latent issues, the extent to which the hazard event can serve as a focusing event for substantive local and state policy initiatives, and the effect of fragmentation of political authority in managing technological hazards. The findings indicate that the explosion amplified several public safety issues and galvanized the public into pressing for major policy initiatives. However, notwithstanding the amplification of several otherwise latent issues, and the flurry of activities by the state and local governments, the hazard event did not seem to be an effective focusing event or trigger mechanism for substantive state and local policy initiatives. In addition, the study provides evidence of the need for a stronger nexus between political authority, land-use planning and technological hazard management

  10. Protein Misfolding Cyclic Amplification of Infectious Prions.

    Science.gov (United States)

    Moda, Fabio

    2017-01-01

    Transmissible spongiform encephalopathies, or prion diseases, are a group of incurable disorders caused by the accumulation of an abnormally folded prion protein (PrP Sc ) in the brain. According to the "protein-only" hypothesis, PrP Sc is the infectious agent able to propagate the disease by acting as a template for the conversion of the correctly folded prion protein (PrP C ) into the pathological isoform. Recently, the mechanism of PrP C conversion has been mimicked in vitro using an innovative technique named protein misfolding cyclic amplification (PMCA). This technology represents a great tool for studying diverse aspects of prion biology in the field of basic research and diagnosis. Moreover, PMCA can be expanded for the study of the misfolding process associated to other neurodegenerative diseases, including Alzheimer's disease, Parkinson's disease, and frontotemporal lobar degeneration. © 2017 Elsevier Inc. All rights reserved.

  11. Markovian Dynamics of Josephson Parametric Amplification

    Directory of Open Access Journals (Sweden)

    W. Kaiser

    2017-09-01

    Full Text Available In this work, we derive the dynamics of the lossy DC pumped non-degenerate Josephson parametric amplifier (DCPJPA. The main element in a DCPJPA is the superconducting Josephson junction. The DC bias generates the AC Josephson current varying the nonlinear inductance of the junction. By this way the Josephson junction acts as the pump oscillator as well as the time varying reactance of the parametric amplifier. In quantum-limited amplification, losses and noise have an increased impact on the characteristics of an amplifier. We outline the classical model of the lossy DCPJPA and derive the available noise power spectral densities. A classical treatment is not capable of including properties like spontaneous emission which is mandatory in case of amplification at the quantum limit. Thus, we derive a quantum mechanical model of the lossy DCPJPA. Thermal losses are modeled by the quantum Langevin approach, by coupling the quantized system to a photon heat bath in thermodynamic equilibrium. The mode occupation in the bath follows the Bose-Einstein statistics. Based on the second quantization formalism, we derive the Heisenberg equations of motion of both resonator modes. We assume the dynamics of the system to follow the Markovian approximation, i.e. the system only depends on its actual state and is memory-free. We explicitly compute the time evolution of the contributions to the signal mode energy and give numeric examples based on different damping and coupling constants. Our analytic results show, that this model is capable of including thermal noise into the description of the DC pumped non-degenerate Josephson parametric amplifier.

  12. Ground amplification determined from borehole accelerograms

    International Nuclear Information System (INIS)

    Archuleta, R.J.; Seale, S.H.

    1991-01-01

    The Garner Valley downhole array (GVDA) consists of one surface accelerometer and four downhole accelerometers at depths of 6 m, 15 m, 22m, and 220 m. The five, three-component vertical array of dual-gain accelerometers are capable of measuring accelerations from 3 x 10 -6 g to 2.0 g over a frequency range from 0.0 Hz (0.025, high-gain) Hz to 100 Hz. The site (33 degree 41.60' N, 116 degree 40.20 degree W) is only seven kilometers off the trace of the San Jacinto fault, the most active strand of the San Andreas fault system in southern California and only about 35 km from the San Andreas fault itself. Analysis of individual spectra and spectral ratios for the various depths shows that the zone of weathered granite has a pronounced effect on the spectral amplitudes for frequencies greater than 40 Hz. The soil layer impedance may amplify the high frequencies more than it attenuates. This result must be checked more thoroughly with special consideration of the spectra of the P-wave coda on the horizontal components. Analysis of the P-wave spectra and the spectral ratios shows an increased amplification in the same frequency range (60-90 Hz) where the S-wave spectral ratios imply a change in the attenuation. Comparison of acceleration spectra from two earthquakes, M L 4.2 and M L 2.5 that have nearly the same hypocenter, shows that the near surface amplification and attenuation is nearly the same for both earthquakes. However, the earthquakes themselves are different if we can assume that the recording at 220 m reflects the source spectra with a slight attenuation. The M L 2.5 earthquake has significantly greater high frequency content if the spectra are normalized at the low frequency, i.e., normalization by seismic moment

  13. Evaluation of loop mediated isothermal amplification for diagnosis of ...

    African Journals Online (AJOL)

    Tuberculosis (TB) remains an important global public health problem. The lack of rapid and accurate diagnostic testing is an important impediment to global tuberculosis control. Loop mediated isothermal amplification (LAMP) is a rapid method for nucleic acid amplification. In this study, we assessed the performance of an ...

  14. Whole genome amplification: Use of advanced isothermal method

    African Journals Online (AJOL)

    Yomi

    2010-12-29

    Dec 29, 2010 ... example, hydrodynamic shearing machine (Arneson et al., 2008b). For validation of whole genome amplification,. Tanabe et al. (2003) have used exon amplification and genotyping of 307 microsatellites, in addition to array CGH. Analyzing of 307 microsatellites distributed throughout the genome revealed ...

  15. The rolling circle amplification and next generation sequencing ...

    African Journals Online (AJOL)

    Titus

    2016-09-14

    Sep 14, 2016 ... Rolling circle amplification is a simple approach of enriching populations of single-stranded DNA plant begomovirus ... sequencing by enriching it using rolling circle amplification then determination of the diversity of the cassava mosaic .... pair ended reads while 4 libraries had less than 0.06 ng/ul and had ...

  16. The rolling circle amplification and next generation sequencing ...

    African Journals Online (AJOL)

    Rolling circle amplification is a simple approach of enriching populations of single-stranded DNA plant begomovirus genomes (genus, Begomovirus; family, Geminiviridae). This is an innovative approach that utilizes the robustness of the bacteriophage phi29 DNA polymerase used in circle amplification, together with deep ...

  17. Plasma-based creation of short light pulses: analysis and simulation of amplification and focusing

    Czech Academy of Sciences Publication Activity Database

    Riconda, C.; Weber, Stefan A.; Lancia, L.; Marqués, J.-R.; Mourou, G.; Fuchs, J.

    2015-01-01

    Roč. 57, č. 1 (2015), s. 014002 ISSN 0741-3335 R&D Projects: GA MŠk ED1.1.00/02.0061; GA MŠk EE2.3.20.0279 Grant - others:ELI Beamlines(XE) CZ.1.05/1.1.00/02.0061; LaserZdroj (OP VK 3)(XE) CZ.1.07/2.3.00/20.0279 Institutional support: RVO:68378271 Keywords : plasma-based amplification * PIC simulations * parametric instabilities Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 2.404, year: 2015

  18. An ultra-high gain and efficient amplifier based on Raman amplification in plasma

    Czech Academy of Sciences Publication Activity Database

    Vieux, Grégory; Cipiccia, S.; Grant, D.W.; Lemos, N.; Grant, P.; Ciocarlan, C.; Ersfeld, B.; Hur, M.S.; Lepipas, P.; Manahan, G.G.; Raj, G.; Reboredo Gil, D.; Subiel, A.; Welsh, G.H.; Wiggins, S.M.; Yoffe, S.R.; Farmer, J.P.; Aniculaesei, C.; Brunetti, E.; Yang, X.; Heathcote, R.; Nersisyan, G.; Lewis, C. L. S.; Pukhov, A.; Dias, J.M.; Jaroszynski, D.A.

    2017-01-01

    Roč. 7, May (2017), s. 1-7, č. článku 2399. ISSN 2045-2322 R&D Projects: GA MŠk EF15_008/0000162; GA MŠk LQ1606 EU Projects: European Commission(XE) 654148 - LASERLAB-EUROPE Grant - others:ELI Beamlines(XE) CZ.02.1.01/0.0/0.0/15_008/0000162 Institutional support: RVO:68378271 Keywords : laser-pulse amplification * beams * wave Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: Fluids and plasma physics (including surface physics) Impact factor: 4.259, year: 2016

  19. Broadening and Amplification of an Infrared Femtosecond Pulse for Optical Parametric Chirped-Pulse Amplification

    International Nuclear Information System (INIS)

    Wang He-Lin; Yang Ai-Jun; Leng Yu-Xin

    2011-01-01

    A high-average-power diode-pumped narrowband regenerative chirped pulse amplifier is developed using the thin-rod Nd:YAG laser architecture for optical parametric chirped-pulse amplification (OPCPA). The effect of the etalons on the amplified pulse in the regenerative cavity is studied experimentally and theoretically. By inserting glass etalons of thickness 1 mm and 5 mm into the regenerative cavity, the pre-stretching pulse from an Öffner stretcher is further broadened to above 200ps, which matches the amplification windows of the signal pulses in OPCPA and is suitable for use as a pump source in the OPCPA system. The bandwidth of the amplified pulse is 1.5 nm, and an output energy of 2mJ is achieved at a repetition rate of 10Hz. (fundamental areas of phenomenology (including applications))

  20. High resolution micro-pattern gas detectors for particle physics

    Science.gov (United States)

    Shekhtman, L.; Aulchenko, V.; Bobrovnikov, V.; Bondar, A.; Fedotovich, G.; Kudryavtsev, V.; Maltsev, T.; Nikolenko, D.; Rachek, I.; Zhilich, V.; Zhulanov, V.

    2017-07-01

    Micro-pattern gaseous detectors (MPGDs) allow operation at very high background particle flux with high efficiency and spatial resolution. This combination of parameters determines the main application of these detectors in particle physics experiments: precise tracking in the areas close to the beam and in the end-cap regions of general-purpose detectors. MPGDs of different configurations have been developed and are under development for several experiments in the Budker INP. The system of eight two-coordinate detectors based on a cascade of Gas Electron Multipliers (GEM) is working in the KEDR experiment at the VEPP-4M collider in the tagging system that detects electrons and positrons that lost their energy in two-photon interactions and left the equilibrium orbit due to a dedicated magnetic system. Another set of cascaded GEM detectors is developed for the almost-real Photon Tagging System (PTS) of the DEUTRON facility at the VEPP-3 storage ring. The PTS contains three very light detectors with very high spatial resolution (below 50 μm). Dedicated detectors based on cascaded GEMs are developed for the extracted electron beam facility at the VEPP-4M collider. These devices will allow precise particle tracking with minimal multiple scattering due to very low material content. An upgrade of the coordinate system of the CMD-3 detector at the VEPP-2000 collider is proposed on the basis of the resistive micro-WELL (μ-rWELL). A research activity on this subject has just started.

  1. Use of Excel ion exchange equilibrium solver with WinGEMS to model and predict NPE distribution in the Mead/Westvaco Evandale, TX, hardwood bleach plant

    Science.gov (United States)

    Christopher Litvay; Alan Rudie; Peter Hart

    2003-01-01

    An Excel spreadsheet developed to solve the ion-exchange equilibrium in wood pulps has been linked by dynamic data exchange to WinGEMS and used to model the non-process elements in the hardwood bleach plant of the Mead/Westvaco Evandale mill. Pulp and filtrate samples were collected from the diffusion washers and final wash press of the bleach plant. A WinGEMS model of...

  2. Clinical application of somatosensory amplification in psychosomatic medicine

    Directory of Open Access Journals (Sweden)

    Nakao Mutsuhiro

    2007-10-01

    Full Text Available Abstract Many patients with somatoform disorders are frequently encountered in psychosomatic clinics as well as in primary care clinics. To assess such patients objectively, the concept of somatosensory amplification may be useful. Somatosensory amplification refers to the tendency to experience a somatic sensation as intense, noxious, and disturbing. It may have a role in a variety of medical conditions characterized by somatic symptoms that are disproportionate to demonstrable organ pathology. It may also explain some of the variability in somatic symptomatology found among different patients with the same serious medical disorder. It has been assessed with a self-report questionnaire, the Somatosensory Amplification Scale. This instrument was developed in a clinical setting in the U.S., and the reliability and validity of the Japanese and Turkish versions have been confirmed as well. Many studies have attempted to clarify the specific role of somatosensory amplification as a pathogenic mechanism in somatization. It has been reported that somatosensory amplification does not correlate with heightened sensitivity to bodily sensations and that emotional reactivity exerts its influence on somatization via a negatively biased reporting style. According to our recent electroencephalographic study, somatosensory amplification appears to reflect some aspects of long-latency cognitive processing rather than short-latency interoceptive sensitivity. The concept of somatosensory amplification can be useful as an indicator of somatization in the therapy of a broad range of disorders, from impaired self-awareness to various psychiatric disorders. It also provides useful information for choosing appropriate pharmacological or psychological therapy. While somatosensory amplification has a role in the presentation of somatic symptoms, it is closely associated with other factors, namely, anxiety, depression, and alexithymia that may also influence the same

  3. Clinical application of somatosensory amplification in psychosomatic medicine

    Science.gov (United States)

    Nakao, Mutsuhiro; Barsky, Arthur J

    2007-01-01

    Many patients with somatoform disorders are frequently encountered in psychosomatic clinics as well as in primary care clinics. To assess such patients objectively, the concept of somatosensory amplification may be useful. Somatosensory amplification refers to the tendency to experience a somatic sensation as intense, noxious, and disturbing. It may have a role in a variety of medical conditions characterized by somatic symptoms that are disproportionate to demonstrable organ pathology. It may also explain some of the variability in somatic symptomatology found among different patients with the same serious medical disorder. It has been assessed with a self-report questionnaire, the Somatosensory Amplification Scale. This instrument was developed in a clinical setting in the U.S., and the reliability and validity of the Japanese and Turkish versions have been confirmed as well. Many studies have attempted to clarify the specific role of somatosensory amplification as a pathogenic mechanism in somatization. It has been reported that somatosensory amplification does not correlate with heightened sensitivity to bodily sensations and that emotional reactivity exerts its influence on somatization via a negatively biased reporting style. According to our recent electroencephalographic study, somatosensory amplification appears to reflect some aspects of long-latency cognitive processing rather than short-latency interoceptive sensitivity. The concept of somatosensory amplification can be useful as an indicator of somatization in the therapy of a broad range of disorders, from impaired self-awareness to various psychiatric disorders. It also provides useful information for choosing appropriate pharmacological or psychological therapy. While somatosensory amplification has a role in the presentation of somatic symptoms, it is closely associated with other factors, namely, anxiety, depression, and alexithymia that may also influence the same. The specific role of

  4. Does GEM-Encoding Clinical Practice Guidelines Improve the Quality of Knowledge Bases? A Study with the Rule-Based Formalism

    Science.gov (United States)

    Georg, Gersende; Séroussi, Brigitte; Bouaud, Jacques

    2003-01-01

    The aim of this work was to determine whether the GEM-encoding step could improve the representation of clinical practice guidelines as formalized knowledge bases. We used the 1999 Canadian recommendations for the management of hypertension, chosen as the knowledge source in the ASTI project. We first clarified semantic ambiguities of therapeutic sequences recommended in the guideline by proposing an interpretative framework of therapeutic strategies. Then, after a formalization step to standardize the terms used to characterize clinical situations, we created the GEM-encoded instance of the guideline. We developed a module for the automatic derivation of a rule base, BR-GEM, from the instance. BR-GEM was then compared to the rule base, BR-ASTI, embedded within the critic mode of ASTI, and manually built by two physicians from the same Canadian guideline. As compared to BR-ASTI, BR-GEM is more specific and covers more clinical situations. When evaluated on 10 patient cases, the GEM-based approach led to promising results. PMID:14728173

  5. An improved resonantly driven piezoelectric gas pump

    International Nuclear Information System (INIS)

    Wu, Yue; Liu, Yong; Liu, Jianfang; Jiao, Xiaoyang; Yang, Zhigang; Wang, Long

    2013-01-01

    Piezoelectric pumps have the potential to be used in a variety of applications, such as in air circulation and compression. However, piezoelectric membrane pumps do not have enough driving capacity, and the heat induced during the direct contact between the driving part and the gas medium cannot be dissipated smoothly. When the gas is blocked, the piezoelectric vibrator generates heat quickly, which may eventually lead to damage. Resonantly driven piezoelectric stack pumps have high performance but no price advantage. In this situation, a novel, resonantly driven piezoelectric gas pump with annular bimorph as the driver is presented. In the study, the working principle of the novel pump was analyzed, the vibration mechanics model was determined, and the displacement amplified theory was studied. The outcome indicates that the displacement amplification factor is related with the original displacement provided by the piezoelectric bimorph. In addition, the displacement amplification effect is related to the stiffness of the spring lamination, adjustment spring, and piezoelectric vibrator, as well as to the systematic damping factor and the driving frequency. The experimental prototypes of the proposed pump were designed, and the displacement amplification effect and gas output performance were measured. At 70 V of sinusoidal AC driving voltage, the improved pump amplified the piezoelectric vibrator displacement by 4.2 times, the maximum gas output flow rate reached 1685 ml/min, and the temperature of the bimorph remained normal after 2000 hours of operation when the gas medium was blocked.

  6. Study on the Development of Industry of Internet of Things Based on Competitive GEM Model in Fujian Province

    Directory of Open Access Journals (Sweden)

    Di Jun An

    2016-01-01

    Full Text Available Firstly, the basic theories of internet of things, competitive GEM model and industrial development in Fujian Province were studied in this paper. Then, the factors influencing the cultivation of industrial competitiveness of the internet of things was observed and finally the suggestions on enhancing the competitiveness of internet of things and strengthening the cultivation of talents of internet of things were put forward.

  7. Optimal Estimation-Based Algorithm to Retrieve Aerosol Optical Properties for GEMS Measurements over Asia

    Directory of Open Access Journals (Sweden)

    Mijin Kim

    2018-01-01

    Full Text Available The Geostationary Environment Monitoring Spectrometer (GEMS is scheduled to be in orbit in 2019 onboard the GEO-KOMPSAT 2B satellite and will continuously monitor air quality over Asia. The GEMS will make measurements in the UV spectrum (300–500 nm with 0.6 nm resolution. In this study, an algorithm is developed to retrieve aerosol optical properties from UV-visible measurements for the future satellite instrument and is tested using 3 years of existing OMI L1B data. This algorithm provides aerosol optical depth (AOD, single scattering albedo (SSA and aerosol layer height (ALH using an optimized estimation method. The retrieved AOD shows good correlation with Aerosol Robotic Network (AERONET AOD with correlation coefficients of 0.83, 0.73 and 0.80 for heavy-absorbing fine (HAF particles, dust and non-absorbing (NA particles, respectively. However, regression tests indicate underestimation and overestimation of HAF and NA AOD, respectively. In comparison with AOD from the OMI/Aura Near-UV Aerosol Optical Depth and Single Scattering Albedo 1-orbit L2 Swath 13 km × 24 km V003 (OMAERUV algorithm, the retrieved AOD has a correlation coefficient of 0.86 and linear regression equation, AODGEMS = 1.18AODOMAERUV + 0.09. An uncertainty test based on a reference method, which estimates retrieval error by applying the algorithm to simulated radiance data, revealed that assumptions in the spectral dependency of aerosol absorptivity in the UV cause significant errors in aerosol property retrieval, particularly the SSA retrieval. Consequently, retrieved SSAs did not show good correlation with AERONET values. The ALH results were qualitatively compared with the Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP products and were found to be well correlated for highly absorbing aerosols. The difference between the attenuated-backscatter-weighted height from CALIOP and retrieved ALH were mostly closed to zero when the retrieved AOD is higher than 0.8 and

  8. The Australian bushfires of February 2009: MIPAS observations and GEM-AQ model results

    Directory of Open Access Journals (Sweden)

    N. Glatthor

    2013-02-01

    Full Text Available Starting on 7 February 2009, southeast Australia was devastated by large bushfires, which burned an area of about 3000 km2 on this day alone. This event was extraordinary, because a large number of combustion products were transported into the uppermost troposphere and lower stratosphere within a few days. Various biomass burning products released by the fire were observed by the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS on the Envisat satellite. We tracked the plume using MIPAS C2H2, HCN and HCOOH single-scan measurements on a day-to-day basis. The measurements were compared with a high-resolution model run of the Global Environmental Multiscale Air Quality (GEM-AQ model. Generally there is good agreement between the spatial distribution of measured and modelled pollutants. Both MIPAS and GEM-AQ show a fast southeastward transport of the pollutants to New Zealand within one day. During the following 3–4 days, the plume remained northeastward of New Zealand and was located at altitudes of 15 to 18 km. Thereafter its lower part was transported eastward, followed by westward transport of its upper part. On 17 February the eastern part had reached southern South America and on 20 February the central South Atlantic. On the latter day a second relic of the plume was observed moving eastward above the South Pacific. Between 20 February and the first week of March, the upper part of the plume was transported westward over Australia and the Indian Ocean towards southern Africa. First evidence for entry of the pollutants into the stratosphere was found in MIPAS data of 11 February, followed by larger amounts on 17 February and the days thereafter. From MIPAS data, C2H2/HCN and HCOOH/HCN enhancement ratios of 0.76 and 2.16 were calculated for the first days after the outbreak of the fires, which are considerably higher than the emission ratios assumed for the model run and at

  9. Glycemic load, exercise, and monitoring blood glucose (GEM): A paradigm shift in the treatment of type 2 diabetes mellitus.

    Science.gov (United States)

    Cox, Daniel J; Taylor, Ann G; Singh, Harsimran; Moncrief, Matthew; Diamond, Anne; Yancy, William S; Hegde, Shefali; McCall, Anthony L

    2016-01-01

    This preliminary RCT investigated whether an integrated lifestyle modification program that focuses on reducing postprandial blood glucose through replacing high with low glycemic load foods and increasing routine physical activities guided by systematic self-monitoring of blood glucose (GEM) could improve metabolic control of adults with type 2 diabetes mellitus, without compromising other physiological parameters. Forty-seven adults (mean age 55.3 years) who were diagnosed with type 2 diabetes mellitus for less than 5 years (mean 2.1 years), had HbA1c ≥ 7% (mean 8.4%) and were not taking blood glucose lowering medications, were randomized to routine care or five 1-h instructional sessions of GEM. Assessments at baseline and 6 months included a physical exam, metabolic and lipid panels, and psychological questionnaires. The GEM intervention led to significant improvements in HbA1c (decreasing from 8.4 to 7.4% [69-57 mmol/mol] compared with 8.3 to 8.3% [68-68 mmol/mol] for routine care; Interaction ptype 2 diabetes mellitus. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  10. A GEM-TPC in twin configuration for the Super-FRS tracking of heavy ions at FAIR

    Science.gov (United States)

    García, F.; Grahn, T.; Hoffmann, J.; Jokinen, A.; Kaya, C.; Kunkel, J.; Rinta-Antila, S.; Risch, H.; Rusanov, I.; Schmidt, C. J.; Simon, H.; Simons, C.; Turpeinen, R.; Voss, B.; Äystö, J.; Winkler, M.

    2018-03-01

    The GEM-TPC described herein will be part of the standard beam-diagnostics equipment of the Super-FRS. This chamber will provide tracking information for particle identification at rates up to 1 MHz on an event-by-event basis. The key requirements of operation for these chambers are: close to 100% tracking efficiency under conditions of high counting rate, spatial resolution below 1 mm and a superb large dynamic range covering projectiles from Z = 1 up to Z = 92. The current prototype consists of two GEM-TPCs inside a single vessel, which are operating independently and have electrical drift fields in opposite directions. The twin configuration is done by flipping one of the GEM-TPCs on the middle plane with respect to the second one. In order to put this development in context, the evolution of previous prototypes will be described and its performances discussed. Finally, this chamber was tested at the University of Jyväskylä accelerator with proton projectiles and at GSI with Uranium, Xenon, fragments and Carbon beams. The results obtained have shown a position resolution between 120 to 300 μm at moderate counting rate under conditions of full tracking efficiency.

  11. ENED-GEM: A Conceptual Framework Model for Psychological Enjoyment Factors and Learning Mechanisms in Educational Games about the Environment

    Directory of Open Access Journals (Sweden)

    Kristoffer S. Fjællingsdal

    2017-06-01

    Full Text Available Based on a thorough review of psychological literature, this article seeks to develop a model of game enjoyment and environmental learning (ENvironmental EDucational Game Enjoyment Model, ENED-GEM and delineate psychological processes that might facilitate learning and inspire behavioral change from educational games about the environment. A critically acclaimed digital educational game about environmental issues (Fate of the World by Red Redemption/Soothsayer Games was used as a case study. Two hundred forty-nine reviews of the game from the popular gaming and reviewing platform known as Steam were analyzed by means of a thematic content analysis in order to identify key player enjoyment factors believed to be relevant to the process of learning from games, as well as to gain an understanding of positive and negative impressions about the game’s general content. The end results of the thematic analysis were measured up to the suggested ENED-GEM framework. Initial results generally support the main elements of the ENED-GEM, and future research into the importance of these individual core factors is outlined.

  12. Evaluation of the influence of the TH-GEM detector components in dosimetric measurements of standard mammography beams

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Natália F.; Castro, Maysa C.; Caldas, Linda V.E., E-mail: nsilva@ipen.br, E-mail: maysadecastro@gmail.com, E-mail: fbelonsi@gmail.com, E-mail: lcaldas@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil); Silva, Tiago F.; Cintra, Felipe B.; Luz, Hugo N. da, E-mail: tfsilva@if.usp.br, E-mail: hugonluz@if.usp.br [Universidade de São Paulo (IF/USP), São Paulo, SP (Brazil). Instituto de Física

    2017-07-01

    GEM detectors have found applications in many areas due to their simplicity of construction, low cost, ruggedness and diversity of shape. A dosimeter with these qualities presents utility in several applications, as for example in diagnostic and therapeutic medicine, industrial radiography and nuclear meters. Furthermore, the high sensitivity provided by GEM detectors may extend their applications in low dose dosimetry. Based on these facts, it may be interesting to produce a prototype of a portable TH-GEM type detector with characteristics suitable for dosimetric use in X-rays with low and medium energies. The precise determination of the dosimeter characteristics is very important for laboratories of instrument calibration, as well as to determine how the various components of the detector may influence on the energy deposited in the sensitive volume. In this work, the results obtained about the influence of each one of the components present in this type of detector in standard mammography beams is presented. The code MCNP5 was used. The results allowed the adaptation of the detector to the desired conditions. (author)

  13. Effect of progressive visual error amplification on human motor adaptation.

    Science.gov (United States)

    Sung, Cynthia; O'Malley, Marcia K

    2011-01-01

    Amplification of error has been shown to be an effective technique in increasing the rate and extent of learning for motor tasks and has the potential to accelerate rehabilitation following motor impairment. However, current error amplification methods suffer from reduced effectiveness towards the end of training. In this paper, we propose a new approach, progressive error amplification, in which error gains increase as a trainee's performance improves. We tested this approach against conventional error augmentation in a controlled experiment wherein 30 subjects adapted to a visually distorted environment by performing target-hitting tasks under one of three conditions (control, constant error amplification, progressive error amplification). Our results showed that compared with repeated practice, error amplification does not accelerate learning or result in improved task performance with respect to trajectory error, although progressive error amplification does produce lower trajectory errors when training conditions are in effect. These results indicate a need for further tuning of error augmentation methods in order to determine their true potential as a training method. © 2011 IEEE

  14. Nucleic acid amplification: Alternative methods of polymerase chain reaction

    Directory of Open Access Journals (Sweden)

    Md Fakruddin

    2013-01-01

    Full Text Available Nucleic acid amplification is a valuable molecular tool not only in basic research but also in application oriented fields, such as clinical medicine development, infectious diseases diagnosis, gene cloning and industrial quality control. A comperehensive review of the literature on the principles, applications, challenges and prospects of different alternative methods of polymerase chain reaction (PCR was performed. PCR was the first nucleic acid amplification method. With the advancement of research, a no of alternative nucleic acid amplification methods has been developed such as loop mediated isothermal amplification, nucleic acid sequence based amplification, strand displacement amplification, multiple displacement amplification. Most of the alternative methods are isothermal obviating the need for thermal cyclers. Though principles of most of the alternate methods are relatively complex than that of PCR, they offer better applicability and sensitivity in cases where PCR has limitations. Most of the alternate methods still have to prove themselves through extensive validation studies and are not available in commercial form; they pose the potentiality to be used as replacements of PCR. Continuous research is going on in different parts of the world to make these methods viable technically and economically.

  15. HER2 amplification, overexpression and score criteria in esophageal adenocarcinoma

    Science.gov (United States)

    Hu, Yingchuan; Bandla, Santhoshi; Godfrey, Tony E.; Tan, Dongfeng; Luketich, James D.; Pennathur, Arjun; Qiu, Xing; Hicks, David G.; Peters, Jeffrey; Zhou, Zhongren

    2011-01-01

    The HER2 oncogene was recently reported to be amplified and overexpressed in esophageal adenocarcinoma. However, the relationship of HER2 amplification in esophageal adenocarcinoma with prognosis has not been well defined. The scoring systems for clinically evaluating HER2 in esophageal adenocarcinoma are not established. The aims of the study were to establish a HER2 scoring system and comprehensively investigate HER2 amplification and overexpression in esophageal adenocarcinoma and its precursor lesion. Using a tissue microarray, containing 116 cases of esophageal adenocarcinoma, 34 cases of BE, 18 cases of low grade dysplasia and 15 cases of high grade dysplasia, HER2 amplification and overexpression were analyzed by HercepTest and CISH methods. The amplification frequency in an independent series of 116 esophageal adenocarcinoma samples was also analyzed using Affymetrix SNP 6.0 microarrays. In our studies, we have found that HER2 amplification does not associate with poor prognosis in total 232 esophageal adenocarcinoma patients by CISH and high density microarrays. We further confirm the similar frequency of HER2 amplification by CISH (18.10%; 21/116) and SNP 6.0 microarrays (16.4%, 19/116) in esophageal adenocarcinoma. HER2 protein overexpression was observed in 12.1 % (14/116) of esophageal adenocarcinoma and 6.67% (1/15) of HGD. No HER2 amplification or overexpression was identified in BE or LGD. All HER2 protein overexpression cases showed HER2 gene amplification. Gene amplification was found to be more frequent by CISH than protein overexpression in esophageal adenocarcinoma (18.10% vs 12.9%). A modified two-step model for esophageal adenocarcinoma HER-2 testing is recommend for clinical esophageal adenocarcinoma HER-2 trial. PMID:21460800

  16. A mechanism of gene amplification driven by small DNA fragments.

    Directory of Open Access Journals (Sweden)

    Kuntal Mukherjee

    Full Text Available DNA amplification is a molecular process that increases the copy number of a chromosomal tract and often causes elevated expression of the amplified gene(s. Although gene amplification is frequently observed in cancer and other degenerative disorders, the molecular mechanisms involved in the process of DNA copy number increase remain largely unknown. We hypothesized that small DNA fragments could be the trigger of DNA amplification events. Following our findings that small fragments of DNA in the form of DNA oligonucleotides can be highly recombinogenic, we have developed a system in the yeast Saccharomyces cerevisiae to capture events of chromosomal DNA amplification initiated by small DNA fragments. Here we demonstrate that small DNAs can amplify a chromosomal region, generating either tandem duplications or acentric extrachromosomal DNA circles. Small fragment-driven DNA amplification (SFDA occurs with a frequency that increases with the length of homology between the small DNAs and the target chromosomal regions. SFDA events are triggered even by small single-stranded molecules with as little as 20-nt homology with the genomic target. A double-strand break (DSB external to the chromosomal amplicon region stimulates the amplification event up to a factor of 20 and favors formation of extrachromosomal circles. SFDA is dependent on Rad52 and Rad59, partially dependent on Rad1, Rad10, and Pol32, and independent of Rad51, suggesting a single-strand annealing mechanism. Our results reveal a novel molecular model for gene amplification, in which small DNA fragments drive DNA amplification and define the boundaries of the amplicon region. As DNA fragments are frequently found both inside cells and in the extracellular environment, such as the serum of patients with cancer or other degenerative disorders, we propose that SFDA may be a common mechanism for DNA amplification in cancer cells, as well as a more general cause of DNA copy number variation

  17. Parametric amplification of waves in non-stationary plasma

    International Nuclear Information System (INIS)

    Krivitskij, V.S.; Vladimirov, S.V.

    1990-01-01

    Using plasma as a nonlinear medium which can provide an amplification of electromagnetic radiation is of a sufficiently great interest now. Parametric amplification of oscillations connected with a nonstationary of the medium parameters is one of such mechanisms which may result in waves growing. To find a growth rate of such a 'parametric' wave amplification (resulting from the dependence ε ωk (vector) (t) it is necessary to clarify how does the dielectric permittivity depend upon time. Namely, the general form of the (linear) connection between an induction D(t) and an intensity Ε(vector) (t) of the electric field is given. (Author)

  18. Amplification and chromosomal dispersion of human endogenous retroviral sequences

    Energy Technology Data Exchange (ETDEWEB)

    Steele, P.E.; Martin, M.A.; Rabson, A.B.; Bryan, T.; O' Brien, S.J.

    1986-09-01

    Endogenous retroviral sequences have undergone amplification events involving both viral and flanking cellular sequences. The authors cloned members of an amplified family of full-length endogenous retroviral sequences. Genomic blotting, employing a flanking cellular DNA probe derived from a member of this family, revealed a similar array of reactive bands in both humans and chimpanzees, indicating that an amplification event involving retroviral and associated cellular DNA sequences occurred before the evolutionary separation of these two primates. Southern analyses of restricted somatic cell hybrid DNA preparations suggested that endogenous retroviral segments are widely dispersed in the human genome and that amplification and dispersion events may be linked.

  19. Amplification and chromosomal dispersion of human endogenous retroviral sequences

    International Nuclear Information System (INIS)

    Steele, P.E.; Martin, M.A.; Rabson, A.B.; Bryan, T.; O'Brien, S.J.

    1986-01-01

    Endogenous retroviral sequences have undergone amplification events involving both viral and flanking cellular sequences. The authors cloned members of an amplified family of full-length endogenous retroviral sequences. Genomic blotting, employing a flanking cellular DNA probe derived from a member of this family, revealed a similar array of reactive bands in both humans and chimpanzees, indicating that an amplification event involving retroviral and associated cellular DNA sequences occurred before the evolutionary separation of these two primates. Southern analyses of restricted somatic cell hybrid DNA preparations suggested that endogenous retroviral segments are widely dispersed in the human genome and that amplification and dispersion events may be linked

  20. PCR amplification on microarrays of gel immobilized oligonucleotides

    Science.gov (United States)

    Strizhkov, Boris; Tillib, Sergei; Mikhailovich, Vladimir; Mirzabekov, Andrei

    2003-11-04

    The invention relates two general methods for performing PCR amplification, combined with the detection and analysis of the PCR products on a microchip. In the first method, the amplification occurs both outside and within a plurality of gel pads on a microchip, with at least one oligonucleotide primer immobilized in a gel pad. In the second method, PCR amplification also takes place within gel pads on a microchip, but the pads are surrounded by a hydrophobic liquid such as that which separates the individual gel pads into environments which resemble micro-miniaturized test tubes.