WorldWideScience

Sample records for gels photons electrons

  1. Optical signal response pf the alanine gel solution for photons and electrons clinical beams

    International Nuclear Information System (INIS)

    Silva, Cleber Feijo; Campos, Leticia Lucente

    2009-01-01

    Alanine gel dosimeter is a new gel material developed at IPEN that presents significant improvement on previous alanine systems developed by Costa (1994). The measure technique is based on the transformation of ferrous ions (Fe 2+ ) in ferric ions (Fe 3+ ) after irradiation. The DL-Alanine (C 3 H 7 NO 2 ) is an aminoacid tissue equivalent that improves the production of ferric ions in the solution. This work aims to study the comparison of optical signal response of the alanine gel solution for photons and electrons clinical beams. It was observed that the calibration factor can be considered independent of quality of the radiation for photons and electrons clinical beams. Therefore, it can be used the same calibration factor for evaluating the absorbed dose in photons and electrons fields in the energy of 6 MeV. Alanine Gel Dosimeter presents good performance and can be useful as alternative dosimeter in the radiotherapy area using MRI technique for 3D dose distribution evaluation. (author)

  2. Effect of silicone gel breast prosthesis on electron and photon dose distributions

    Energy Technology Data Exchange (ETDEWEB)

    Krishnan, L.; St. George, F.J.; Mansfield, C.M.; Krishnan, E.C.

    1983-01-01

    The effect of a silicone gel breast prosthesis on the absorbed dose distribution of 9--20 MeV electron beams and 1.25--15 MV photon beams was studied. Compared to water measurements, at depths smaller than the practical range of the electron beams, the central axis depth dose values below the prothesis were lower for all energies by as much as 3.5%. However, at depths near the practical range, the central axis depth dose values for the prosthesis were greater than that of water by as much as 33%. Since this occurs near the end of the electron range, the resultant difference may not be clinically significant. Results of the effect of breast prosthesis on photon depth dose distributions reveal that no clinically significant perturbation is produced by the breast prosthesis using Co-60, 6- and 15-MV radiations.

  3. Effect of silicone gel breast prosthesis on electron and photon dose distributions

    International Nuclear Information System (INIS)

    Krishnan, L.; St George, F.J.; Mansfield, C.M.; Krishnan, E.C.

    1983-01-01

    The effect of a silicone gel breast prosthesis on the absorbed dose distribution of 9-20 MeV electron beams and 1.25-15 MV photon beams was studied. Compared to water measurements, at depths smaller than the practical range of the electron beams, the central axis depth dose values below the prosthesis were lower for all energies by as much as 3.5%. However, at depths near the practical range, the central axis depth dose values for the prosthesis were greater than that of water by as much as 33%. Since this occurs near the end of the electron range, the resultant difference may not be clinically significant. Results of the effect of breast prosthesis on photon depth dose distributions reveal that no clinically significant perturbation is produced by the breast prosthesis using Co-60, 6- and 15-MV radiations

  4. Effect of silicone gel breast prosthesis on electron and photon dose distributions

    International Nuclear Information System (INIS)

    Krishnan, L.; St George, F.J.; Mansfield, C.M.; Krishnan, E.C.

    1983-01-01

    The effect of a silicone gel breast prosthesis on the absorbed dose distribution of 9--20 MeV electron beams and 1.25--15 MV photon beams was studied. Compared to water measurements, at depths smaller than the practical range of the electron beams, the central axis depth dose values below the prothesis were lower for all energies by as much as 3.5%. However, at depths near the practical range, the central axis depth dose values for the prosthesis were greater than that of water by as much as 33%. Since this occurs near the end of the electron range, the resultant difference may not be clinically significant. Results of the effect of breast prosthesis on photon depth dose distributions reveal that no clinically significant perturbation is produced by the breast prosthesis using Co-60, 6- and 15-MV radiations

  5. Optical and energy dependent response of the alanine gel solution produced at IPEN to clinical photons and electrons beams

    International Nuclear Information System (INIS)

    Silva, Cleber F.

    2011-01-01

    The DL-Alanine (C 3 H 7 NO 2 ) is an amino acid tissue equivalent traditionally used as standard dosimetric material in EPR dosimetry. Recently, it has been studied to be applied in gel dosimetry, considering that the addition of Alanine in the Fricke gel solution improves the production of ferric ions radiation induced. The spectrophotometric evaluation technique can be used comparing the two spectrum wavelengths bands: 457 nm band that corresponds to ferrous ions and 588 nm band that corresponds to ferric ions concentration to evaluate the dosimetric properties of this material. The performance of the Alanine gel solution developed at IPEN has been firstly studied using the spectrophotometric technique aiming to apply this material to 3D clinical doses evaluations using MRI technique. In this work, the optical and the energy dependent response of this solution submitted to clinical photons and electrons beams were studied. Different batches of gel solutions were prepared and maintained at low temperature during 12 h to solidification. Before irradiation, the samples were maintained during 1 h at room temperature. The photons and electrons irradiations were carried out using a Varian 2100C Medical Linear Accelerator of the Radiotherapy Department of the Hospital das Clinicas of the University of Sao Paulo with absorbed doses between 1 and 40 Gy; radiation field of 10 x 10 cm 2 ; photon energies of 6 MeV and 15 MeV; and electron with energies between 6 and 15 MeV. The obtained results indicate that signal response dependence for clinical photons and electrons beams, to the same doses, for Alanine gel dosimeter is better than 3.6 % (1σ), and the energy dependence response, to the same doses, is better 3% (1σ) for both beams. These results indicate that the same calibration factor can be used and the optical response is energy independent in the studied dose range and clinical photons and electrons beams energies. (author)

  6. Dosimetric evaluation of spectrophotometric response of alanine gel solution for gamma, photons, electrons and thermal neutrons radiations

    International Nuclear Information System (INIS)

    Silva, Cleber Feijo

    2009-01-01

    Alanine Gel Dosimeter is a new gel material developed at IPEN that presents significant improvement on Alanine system developed by Costa. The DL-Alanine (C 3 H 7 NO 2 ) is an amino acid tissue equivalent that improves the production of ferric ions in the solution. This work aims to analyse the main dosimetric characteristics this new gel material for future application to measure dose distribution. The performance of Alanine gel solution was evaluated to gamma, photons, electrons and thermal neutrons radiations using the spectrophotometry technique. According to the obtained results for the different studied radiation types, the reproducibility intra-batches and inter-batches is better than 4% and 5%, respectively. The dose response presents a linear behavior in the studied dose range. The response dependence as a function of dose rate and incident energy is better 2% and 3%, respectively. The lower detectable dose is 0.1 Gy. The obtained results indicate that the Alanine gel dosimeter presents good performance and can be useful as an alternative dosimeter in the radiotherapy area, using MRI technique for tridimensional dose distribution evaluation. (author)

  7. Optical signal response pf the alanine gel solution for photons and electrons clinical beams;Resposta espectrofotometrica da solucao gel de alanina para feixes clinicos de fotons e eletrons

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Cleber Feijo; Campos, Leticia Lucente [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2009-07-01

    Alanine gel dosimeter is a new gel material developed at IPEN that presents significant improvement on previous alanine systems developed by Costa (1994). The measure technique is based on the transformation of ferrous ions (Fe{sup 2+}) in ferric ions (Fe{sup 3+}) after irradiation. The DL-Alanine (C{sub 3}H{sub 7}NO{sub 2}) is an aminoacid tissue equivalent that improves the production of ferric ions in the solution. This work aims to study the comparison of optical signal response of the alanine gel solution for photons and electrons clinical beams. It was observed that the calibration factor can be considered independent of quality of the radiation for photons and electrons clinical beams. Therefore, it can be used the same calibration factor for evaluating the absorbed dose in photons and electrons fields in the energy of 6 MeV. Alanine Gel Dosimeter presents good performance and can be useful as alternative dosimeter in the radiotherapy area using MRI technique for 3D dose distribution evaluation. (author)

  8. Electron and Photon ID

    CERN Document Server

    Hryn'ova, Tetiana; The ATLAS collaboration

    2017-01-01

    The identification of prompt photons and the rejection of background coming mostly from photons from hadron decays relies on the high granularity of the ATLAS calorimeter. The electron identification used in ATLAS for run 2 is based on a likelihood discrimination to separate isolated electron candidates from candidates originating from photon conversions, hadron misidentification and heavy flavor decays. In addition, isolation variables are used as further handles to separate signal and background. Several methods are used to measure with data the efficiency of the photon identification requirements, to cover a broad energy spectrum. At low energy, photons from radiative Z decays are used. In the medium energy range, similarities between electrons and photon showers are exploited using Z->ee decays. At high energy, inclusive photon samples are used. The measurement of the efficiencies of the electron identification and isolation cuts are performed with the data using tag and probe techniques with large statis...

  9. Dosimetric evaluation of spectrophotometric response of alanine gel solution for gamma, photons, electrons and thermal neutrons radiations; Avaliacao dosimetrica da resposta espectrofotometrica da solucao gel de alanina para radiacao gama, de fotons, de eletrons e de neutrons termicos

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Cleber Feijo

    2009-07-01

    Alanine Gel Dosimeter is a new gel material developed at IPEN that presents significant improvement on Alanine system developed by Costa. The DL-Alanine (C{sub 3}H{sub 7}NO{sub 2}) is an amino acid tissue equivalent that improves the production of ferric ions in the solution. This work aims to analyse the main dosimetric characteristics this new gel material for future application to measure dose distribution. The performance of Alanine gel solution was evaluated to gamma, photons, electrons and thermal neutrons radiations using the spectrophotometry technique. According to the obtained results for the different studied radiation types, the reproducibility intra-batches and inter-batches is better than 4% and 5%, respectively. The dose response presents a linear behavior in the studied dose range. The response dependence as a function of dose rate and incident energy is better 2% and 3%, respectively. The lower detectable dose is 0.1 Gy. The obtained results indicate that the Alanine gel dosimeter presents good performance and can be useful as an alternative dosimeter in the radiotherapy area, using MRI technique for tridimensional dose distribution evaluation. (author)

  10. Polymers for electronic & photonic application

    CERN Document Server

    Wong, C P

    2013-01-01

    The most recent advances in the use of polymeric materials by the electronic industry can be found in Polymers for Electronic and Photonic Applications. This bookprovides in-depth coverage of photoresis for micro-lithography, microelectronic encapsulants and packaging, insulators, dielectrics for multichip packaging,electronic and photonic applications of polymeric materials, among many other topics. Intended for engineers and scientists who design, process, and manufacturemicroelectronic components, this book will also prove useful for hybrid and systems packaging managers who want to be info

  11. Photonic integration and photonics-electronics convergence on silicon platform

    CERN Document Server

    Liu, Jifeng; Baba, Toshihiko; Vivien, Laurent; Xu, Dan-Xia

    2015-01-01

    Silicon photonics technology, which has the DNA of silicon electronics technology, promises to provide a compact photonic integration platform with high integration density, mass-producibility, and excellent cost performance. This technology has been used to develop and to integrate various photonic functions on silicon substrate. Moreover, photonics-electronics convergence based on silicon substrate is now being pursued. Thanks to these features, silicon photonics will have the potential to be a superior technology used in the construction of energy-efficient cost-effective apparatuses for various applications, such as communications, information processing, and sensing. Considering the material characteristics of silicon and difficulties in microfabrication technology, however, silicon by itself is not necessarily an ideal material. For example, silicon is not suitable for light emitting devices because it is an indirect transition material. The resolution and dynamic range of silicon-based interference de...

  12. Probing plasmonic nanostructures by photons and electrons

    DEFF Research Database (Denmark)

    Kneipp, Katrin; Kneipp, Harald; Kneipp, Janina

    2015-01-01

    We discuss recent developments for studying plasmonic metal nanostructures. Exploiting photons and electrons opens up new capabilities to probe the complete plasmon spectrum including bright and dark modes and related local optical fields at subnanometer spatial resolution. This comprehensive...

  13. Electrons and photons in periodic structures

    DEFF Research Database (Denmark)

    Pedersen, Jesper Goor

    This thesis concerns various theoretical proposals for engineering dispersion relations of photons and electrons for particular applications. The common concept is the use of a periodic modulation to induce new phenomena on length scales comparable with the periodicity of the modulation...... periodic modulation of an electron gas leads to the emergence of localized defect states with energies within the band gap, where no propagating modes exist. Secondly, the divergence of the photonic density of states near a photonic band gap leads to strongly modified light-matter interactions, which has...... applications both in terms of spontaneous emission control and for slow light propagation. We first consider antidot lattices, periodic modulations of the potential of an electron gas. We demonstrate that such structures may serve as an interesting platform for quantum information processing. In particular, we...

  14. Electron dose rate and photon contamination in electron arc therapy

    International Nuclear Information System (INIS)

    Pla, M.; Podgorsak, E.B.; Pla, C.

    1989-01-01

    The electron dose rate at the depth of dose maximum dmax and the photon contamination are discussed as a function of several parameters of the rotational electron beam. A pseudoarc technique with an angular increment of 10 degrees and a constant number of monitor units per each stationary electron field was used in our experiments. The electron dose rate is defined as the electron dose at a given point in phantom divided by the number of monitor units given for any one stationary electron beam. For a given depth of isocenter di the electron dose rates at dmax are linearly dependent on the nominal field width w, while for a given w the dose rates are inversely proportional to di. The dose rates for rotational electron beams with different di are related through the inverse square law provided that the two beams have (di,w) combinations which give the same characteristic angle beta. The photon dose at the isocenter depends on the arc angle alpha, field width w, and isocenter depth di. For constant w and di the photon dose at isocenter is proportional to alpha, for constant alpha and w it is proportional to di, and for constant alpha and di it is inversely proportional to w. The w and di dependence implies that for the same alpha the photon dose at the isocenter is inversely proportional to the electron dose rate at dmax

  15. Electron spectra obtained by photon bombadment

    International Nuclear Information System (INIS)

    Tran Minh Duc

    1981-01-01

    The physical factors modifying the kinetic energy of electrons emitted from a surface by photon irradiation are discussed, mamely: photoemission excitation mechanism and Auger emission, effects of the neutral initial state, of chemical displacements, of ionized final state, of relaxation energy. Spectra structure, spin multiplets energy loss peaks are also explained [fr

  16. Monte Carlo electron/photon transport

    International Nuclear Information System (INIS)

    Mack, J.M.; Morel, J.E.; Hughes, H.G.

    1985-01-01

    A review of nonplasma coupled electron/photon transport using Monte Carlo method is presented. Remarks are mainly restricted to linerarized formalisms at electron energies from 1 keV to 1000 MeV. Applications involving pulse-height estimation, transport in external magnetic fields, and optical Cerenkov production are discussed to underscore the importance of this branch of computational physics. Advances in electron multigroup cross-section generation is reported, and its impact on future code development assessed. Progress toward the transformation of MCNP into a generalized neutral/charged-particle Monte Carlo code is described. 48 refs

  17. LHCb calorimeter electronics. Photon identification. Calorimeter calibration

    International Nuclear Information System (INIS)

    Machefert, F.

    2011-01-01

    LHCb is one of the four large experiments installed on the LHC accelerator ring. The aim of the detector is to precisely measure CP violation observables and rare decays in the B meson sector. The calorimeter system of LHCb is made of four sub-systems: the scintillating pad detector, the pre-shower, the electromagnetic (ECAL) and hadronic (HCAL) calorimeters. It is essential to reconstruct B decays, to efficiently trigger on interesting events and to identify electrons and photons. After a review of the LHCb detector sub-systems, the first part of this document describes the calorimeter electronics. First, the front-end electronics in charge of measuring the ECAL and HCAL signals from the photomultipliers is presented, then the following section is an overview of the control card of the four calorimeters. The chapters three and four concern the test software of this electronics and the technological choices making it tolerant to radiations in the LHCb cavern environment. The measurements performed to ensure this tolerance are also given. The second part of this document concerns both the identification of the photons with LHCb and the calibration of the calorimeters. The photon identification method is presented and the performances given. Finally, the absolute energy calibration of the PRS and ECAL, based on the data stored in 2010 is explained. (author)

  18. Triggering on electrons and photons with CMS

    Directory of Open Access Journals (Sweden)

    Zabi Alexandre

    2012-06-01

    Full Text Available Throughout the year 2011, the Large Hadron Collider (LHC has operated with an instantaneous luminosity that has risen continually to around 4 × 1033cm−2s−1. With this prodigious high-energy proton collisions rate, efficient triggering on electrons and photons has become a major challenge for the LHC experiments. The Compact Muon Solenoid (CMS experiment implements a sophisticated two-level online selection system that achieves a rejection factor of nearly 106. The first level (L1 is based on coarse information coming from the calorimeters and the muon detectors while the High-Level Trigger (HLT combines fine-grain information from all sub-detectors. In this intense hadronic environment, the L1 electron/photon trigger provides a powerful tool to select interesting events. It is based upon information from the Electromagnetic Calorimeter (ECAL, a high-resolution detector comprising 75848 lead tungstate (PbWO4 crystals in a “barrel” and two “endcaps”. The performance as well as the optimization of the electron/photon trigger are presented.

  19. Advanced Photonic and Electronic Systems WILGA 2010

    CERN Document Server

    Romaniuk, R S

    2010-01-01

    SPIE – PSP WILGA Symposium gathers two times a year in January and in May new adepts of advanced photonic and electronic systems. The event is oriented on components and applications. WILGA Symposium on Photonics and Web Engineering is well known on the web for its devotion to “young research” promotion under the eminent sponsorship of international engineering associations like SPIE and IEEE and their Poland Sections or Counterparts. WILGA is supported by the most important national professional organizations like KEiT PAN and PSP-Photonics Society of Poland. The Symposium is organized since 1998 twice a year. It has gathered over 4000 young researchers and published over 2000 papers mainly internationally, including more than 900 in 10 published so far volumes of Proc. SPIE. This paper is a digest of WILGA Symposium Series and WILGA 2010 summary. Introductory part treats WILGA Photonics Applications characteristics over the period 1998-2010. Following part presents a short report on the XXVth and XXVI...

  20. The ATLAS Electron and Photon Trigger

    CERN Document Server

    Jones, Samuel David; The ATLAS collaboration

    2018-01-01

    Electron and photon triggers covering transverse energies from 5 GeV to several TeV are essential for signal selection in a wide variety of ATLAS physics analyses to study Standard Model processes and to search for new phenomena. Final states including leptons and photons had, for example, an important role in the discovery and measurement of the Higgs boson. Dedicated triggers are also used to collect data for calibration, efficiency and fake rate measurements. The ATLAS trigger system is divided in a hardware-based Level-1 trigger and a software-based high-level trigger, both of which were upgraded during the LHC shutdown in preparation for Run-2 operation. To cope with the increasing luminosity and more challenging pile-up conditions at a center-of-mass energy of 13 TeV, the trigger selections at each level are optimized to control the rates and keep efficiencies high. To achieve this goal multivariate analysis techniques are used. The ATLAS electron and photon triggers and their performance with Run 2 dat...

  1. The ATLAS Electron and Photon Trigger

    CERN Document Server

    Jones, Samuel David; The ATLAS collaboration

    2017-01-01

    Electron and photon triggers covering transverse energies from 5 GeV to several TeV are essential for signal selection in a wide variety of ATLAS physics analyses to study Standard Model processes and to search for new phenomena. Final states including leptons and photons had, for example, an important role in the discovery and measurement of the Higgs boson. Dedicated triggers are also used to collect data for calibration, efficiency and fake rate measurements. The ATLAS trigger system is divided in a hardware-based Level-1 trigger and a software-based high-level trigger, both of which were upgraded during the LHC shutdown in preparation for Run-2 operation. To cope with the increasing luminosity and more challenging pile-up conditions at a center-of-mass energy of 13 TeV, the trigger selections at each level are optimized to control the rates and keep efficiencies high. To achieve this goal multivariate analysis techniques are used. The ATLAS electron and photon triggers and their performance with Run 2 dat...

  2. Tunable Temperature Response of a Thermochromic Photonic Gel Sensor Containing N-Isopropylacrylamide and 4-Acryloyilmorpholine

    Directory of Open Access Journals (Sweden)

    Hwanam Kye

    2017-06-01

    Full Text Available In this study, thermochromic photonic gels were fabricated using 2-hydroxyethyl methacrylate (HEMA as a hydrogel building block, and 4-Acryloyl morpholine (ACMO and N-isopropylacrylamide (NIPAAM as thermoresponsive monomers with different critical solution temperature behaviors. Rapid photopolymerization of opal-templated monomer mixtures of varying ACMO contents formed five individual thermochromic inverse opal photonic gels integrated on a single substrate. With temperature variation from 10 °C to 80 °C, the changes in reflective colors and reflectance spectra of the respective thermochromic gels were noted, and λpeak changes were plotted. Because NIPAAM exhibits a lower critical solution temperature (LCST at 33 °C, the NIPAAM-only gel showed a steep slope for dλpeak/dT below 40 °C, whereas the slope became flatter at high temperatures. As the ACMO content increased in the thermochromic gel, the curve of dλpeak/dT turned out to be gradual within the investigated temperature range, exhibiting the entire visible range of colors. The incorporation of ACMO in NIPAAM-based thermochromic gels therefore enabled a better control of color changes at a relatively high-temperature regime compared to a NIPAAM-only gel. In addition, ACMO-containing thermochromic gels exhibited a smaller hysteresis of λpeak for the heating and cooling cycle.

  3. Coupled electron-photon radiation transport

    International Nuclear Information System (INIS)

    Lorence, L.; Kensek, R.P.; Valdez, G.D.; Drumm, C.R.; Fan, W.C.; Powell, J.L.

    2000-01-01

    Massively-parallel computers allow detailed 3D radiation transport simulations to be performed to analyze the response of complex systems to radiation. This has been recently been demonstrated with the coupled electron-photon Monte Carlo code, ITS. To enable such calculations, the combinatorial geometry capability of ITS was improved. For greater geometrical flexibility, a version of ITS is under development that can track particles in CAD geometries. Deterministic radiation transport codes that utilize an unstructured spatial mesh are also being devised. For electron transport, the authors are investigating second-order forms of the transport equations which, when discretized, yield symmetric positive definite matrices. A novel parallelization strategy, simultaneously solving for spatial and angular unknowns, has been applied to the even- and odd-parity forms of the transport equation on a 2D unstructured spatial mesh. Another second-order form, the self-adjoint angular flux transport equation, also shows promise for electron transport

  4. Foldable and Cytocompatible Sol-gel TiO2 Photonics.

    Science.gov (United States)

    Li, Lan; Zhang, Ping; Wang, Wei-Ming; Lin, Hongtao; Zerdoum, Aidan B; Geiger, Sarah J; Liu, Yangchen; Xiao, Nicholas; Zou, Yi; Ogbuu, Okechukwu; Du, Qingyang; Jia, Xinqiao; Li, Jingjing; Hu, Juejun

    2015-09-07

    Integrated photonics provides a miniaturized and potentially implantable platform to manipulate and enhance the interactions between light and biological molecules or tissues in in-vitro and in-vivo settings, and is thus being increasingly adopted in a wide cross-section of biomedical applications ranging from disease diagnosis to optogenetic neuromodulation. However, the mechanical rigidity of substrates traditionally used for photonic integration is fundamentally incompatible with soft biological tissues. Cytotoxicity of materials and chemicals used in photonic device processing imposes another constraint towards these biophotonic applications. Here we present thin film TiO2 as a viable material for biocompatible and flexible integrated photonics. Amorphous TiO2 films were deposited using a low temperature (<250 °C) sol-gel process fully compatible with monolithic integration on plastic substrates. High-index-contrast flexible optical waveguides and resonators were fabricated using the sol-gel TiO2 material, and resonator quality factors up to 20,000 were measured. Following a multi-neutral-axis mechanical design, these devices exhibit remarkable mechanical flexibility, and can sustain repeated folding without compromising their optical performance. Finally, we validated the low cytotoxicity of the sol-gel TiO2 devices through in-vitro cell culture tests. These results demonstrate the potential of sol-gel TiO2 as a promising material platform for novel biophotonic devices.

  5. Generation of Femtosecond Electron and Photon Pulses

    CERN Document Server

    Thongbai, Chitrlada; Kangrang, Nopadol; Kusoljariyakul, Keerati; Rhodes, Michael W; Rimjaem, Sakhorn; Saisut, Jatuporn; Vilaithong, Thiraphat; Wichaisirimongkol, Pathom; Wiedemann, Helmut

    2005-01-01

    Femtosecond electron and photon pulses become a tool of interesting important to study dynamics at molecular or atomic levels. Such short pulses can be generated from a system consisting of an RF-gun with a thermionic cathode, an alpha magnet as a magnetic bunch compressor, and a linear accelerator. The femtosecond electron pulses can be used directly or used as sources to produce electromagnetic radiation of equally short pulses by choosing certain kind of radiation pruduction processes. At the Fast Neutron Research Facility (Thailand), we are especially interested in production of radiation in Far-infrared and X-ray regime. In the far-infrared wavelengths which are longer than the femtosecond pulse length, the radiation is emitted coherently producing intense radiation. In the X-ray regime, development of femtosecond X-ray source is crucial for application in ultrafast science.

  6. Triggering on electrons and photons with CMS

    CERN Document Server

    Zabi, Alexandre

    2012-01-01

    Throughout the year 2011, the Large Hadron Collider (LHC) has operated with an instantaneous luminosity that has risen continually to around 4x10^{33} cm^{-2} s^{-1}. With this prodigious high-energy proton collisions rate, efficient triggering on electrons and photons has become a major challenge for the LHC experiments. The Compact Muon Solenoid (CMS) experiment implements a sophisticated two-level online selection system that achieves a rejection factor of nearly 10^6. The first level (L1) is based on coarse information coming from the calorimeters and the muon detectors while the High-Level Trigger (HLT) combines fine-grain information from all sub-detectors. In this intense hadronic environment, the L1 electron/photon trigger provides a powerful tool to select interesting events. It is based upon information from the Electromagnetic Calorimeter (ECAL), a high-resolution detector comprising 75848 lead tungstate PbWO4 crystals in a "barrel" and two "endcaps''. The performance as well as the optimization ...

  7. Triggering on electrons and photons with CMS

    CERN Document Server

    Zabi, Alexandre

    2012-01-01

    Throughout the year 2011, the Large Hadron Collider (LHC) has operated with an instantaneous luminosity that has risen continually to around 4x10^33cm-2 s-1. With this prodigious high-energy proton collisions rate, efficient triggering on electrons and photons has become a major challenge for the LHC experiments. The Compact Muon Solenoid (CMS) experiment implements a sophisticated two-level online selection system that achieves a rejection factor of nearly 106. The first level (L1) is based on coarse information coming from the calorimeters and the muon detectors while the High-Level Trigger (HLT) combines fine-grain information from all sub-detectors. In this intense hadronic environment, the L1 electron/photon trigger provides a powerful tool to select interesting events. It is based upon information from the Electromagnetic Calorimeter (ECAL), a high-resolution detector comprising 75848 lead tungstate (PbWO4) crystals in a "barrel" and two "endcaps". The performance as well as the optimization of the elec...

  8. Electron and photon identification in the D0 experiment

    Energy Technology Data Exchange (ETDEWEB)

    Abazov, V. M.; Abbott, B.; Acharya, B. S.; Adams, M.; Adams, T.; Agnew, J. P.; Alexeev, G. D.; Alkhazov, G.; Alton, A.; Askew, A.; Atkins, S.; Augsten, K.; Avila, C.; Badaud, F.; Bagby, L.; Baldin, B.; Bandurin, D. V.; Banerjee, S.; Barberis, E.; Baringer, P.; Bartlett, J. F.; Bassler, U.; Bazterra, V.; Bean, A.; Begalli, M.; Bellantoni, L.; Beri, S. B.; Bernardi, G.; Bernhard, R.; Bertram, I.; Besançon, M.; Beuselinck, R.; Bhat, P. C.; Bhatia, S.; Bhatnagar, V.; Blazey, G.; Blessing, S.; Bloom, K.; Boehnlein, A.; Boline, D.; Boos, E. E.; Borissov, G.; Borysova, M.; Brandt, A.; Brandt, O.; Brock, R.; Bross, A.; Brown, D.; Bu, X. B.; Buehler, M.; Buescher, V.; Bunichev, V.; Burdin, S.; Buszello, C. P.; Camacho-Pérez, E.; Casey, B. C. K.; Castilla-Valdez, H.; Caughron, S.; Chakrabarti, S.; Chan, K. M.; Chandra, A.; Chapon, E.; Chen, G.; Cho, S. W.; Choi, S.; Choudhary, B.; Cihangir, S.; Claes, D.; Clutter, J.; Cooke, M.; Cooper, W. E.; Corcoran, M.; Couderc, F.; Cousinou, M. -C.; Cutts, D.; Das, A.; Davies, G.; de Jong, S. J.; De La Cruz-Burelo, E.; Déliot, F.; Demina, R.; Denisov, D.; Denisov, S. P.; Desai, S.; Deterre, C.; DeVaughan, K.; Diehl, H. T.; Diesburg, M.; Ding, P. F.; Dominguez, A.; Dubey, A.; Dudko, L. V.; Duperrina, A.; Dutt, S.; Eads, M.; Edmunds, D.; Ellison, J.; Elvira, V. D.; Enari, Y.; Evans, H.; Evdokimov, V. N.; Feng, L.; Ferbel, T.; Fiedler, F.; Filthaut, F.; Fisher, W.; Fisk, H. E.; Fortner, M.; Fox, H.; Fuess, S.; Garbincius, P. H.; Garcia-Bellido, A.; García-González, J. A.; Gavrilov, V.; Geng, W.; Gerber, C. E.; Gershtein, Y.; Ginther, G.; Golovanov, G.; Grannis, P. D.; Greder, S.; Greenlee, H.; Grenier, G.; Gris, Ph.; Grivaz, J. -F.; Grohsjean, A.; Grünendahl, S.; Grünewald, M. W.; Guillemin, T.; Gutierrez, G.; Gutierrez, P.; Haley, J.; Han, L.; Harder, K.; Harel, A.; Hauptman, J. M.; Hays, J.; Head, T.; Hebbeker, T.; Hedin, D.; Hegab, H.; Heinson, A. P.; Heintz, U.; Hensel, C.; Heredia-De La Cruz, I.; Herner, K.; Hesketh, G.; Hildreth, M. D.; Hirosky, R.; Hoang, T.; Hobbs, J. D.; Hoeneisen, B.; Hogan, J.; Hohlfeld, M.; Holzbauer, J. L.; Howley, I.; Hubacek, Z.; Hynek, V.; Iashvili, I.; Ilchenko, Y.; Illingworth, R.; Ito, A. S.; Jabeen, S.; Jaffré, M.; Jayasinghe, A.; Jeong, M. S.; Jesik, R.; Jiang, P.; Johns, K.; Johnson, E.; Johnson, M.; Jonckheere, A.; Jonsson, P.; Joshi, J.; Jung, A. W.; Juste, A.; Kajfasz, E.; Karmanov, D.; Katsanos, I.; Kehoe, R.; Kermiche, S.; Khalatyan, N.; Khanov, A.; Kharchilava, A.; Kharzheev, Y. N.; Kiselevich, I.; Kohli, J. M.; Kozelov, A. V.; Kraus, J.; Kumar, A.; Kupco, A.; Kurča, T.; Kuzmin, V. A.; Lammers, S.; Lebrun, P.; Lee, H. S.; Lee, S. W.; Lee, W. M.; Lei, X.; Lellouch, J.; Li, D.; Li, H.; Li, L.; Li, Q. Z.; Lim, J. K.; Lincoln, D.; Linnemann, J.; Lipaev, V. V.; Lipton, R.; Liu, H.; Liu, Y.; Lobodenko, A.; Lokajicek, M.; Lopes de Sa, R.; Luna-Garcia, R.; Lyon, A. L.; Maciel, A. K. A.; Madar, R.; Magaña-Villalba, R.; Malik, S.; Malyshev, V. L.; Mansour, J.; Martínez-Ortega, J.; McCarthy, R.; McGivern, C. L.; Meijer, M. M.; Melnitchouk, A.; Menezes, D.; Mercadante, P. G.; Merkin, M.; Meyer, A.; Meyer, J.; Miconi, F.; Mondal, N. K.; Mulhearn, M.; Nagy, E.; Narain, M.; Nayyar, R.; Neal, H. A.; Negret, J. P.; Neustroev, P.; Nguyen, H. T.; Nunnemann, T.; Orduna, J.; Osman, N.; Osta, J.; Pal, A.; Parashar, N.; Parihar, V.; Park, S. K.; Partridge, R.; Parua, N.; Patwa, A.; Penning, B.; Perfilov, M.; Peters, Y.; Petridis, K.; Petrillo, G.; Pétroff, P.; Pleier, M. -A.; Podstavkov, V. M.; Popov, A. V.; Prewitt, M.; Price, D.; Prokopenko, N.; Qian, J.; Quadt, A.; Quinn, B.; Raja, R.; Ratoff, P. N.; Razumov, I.; Ripp-Baudot, I.; Rizatdinova, F.; Rominsky, M.; Ross, A.; Royon, C.; Rubinov, P.; Ruchti, R.; Sajot, G.; Sánchez-Hernández, A.; Sanders, M. P.; Santos, A. S.; Savage, G.; Sawyer, L.; Scanlon, T.; Schamberger, R. D.; Scheglov, Y.; Schellman, H.; Schwanenberger, C.; Schwienhorst, R.; Sekaric, J.; Severini, H.; Shabalina, E.; Shary, V.; Shaw, S.; Shchukin, A. A.; Simak, V.; Skubic, P.; Slattery, P.; Smirnov, D.; Snow, G. R.; Snow, J.; Snyder, S.; Söldner-Rembold, S.; Sonnenschein, L.; Soustruznik, K.; Stark, J.; Stoyanova, D. A.; Strauss, M.; Suter, L.; Svoisky, P.; Titov, M.; Tokmenin, V. V.; Tsai, Y. -T.; Tsybychev, D.; Tuchming, B.; Tully, C.; Uvarov, L.; Uvarov, S.; Uzunyan, S.; Van Kooten, R.; van Leeuwen, W. M.; Varelas, N.; Varnes, E. W.; Vasilyev, I. A.; Verkheev, A. Y.; Vertogradov, L. S.; Verzocchi, M.; Vesterinen, M.; Vilanova, D.; Vokac, P.; Wahl, H. D.; Wang, M. H. L. S.; Warchol, J.; Watts, G.; Wayne, M.; Weichert, J.; Welty-Rieger, L.; Williams, M. R. J.; Wilson, G. W.; Wobisch, M.; Wood, D. R.; Wyatt, T. R.; Xie, Y.; Yamada, R.; Yang, S.; Yasuda, T.; Yatsunenko, Y. A.; Ye, W.; Ye, Z.; Yin, H.; Yip, K.; Youn, S. W.; Yu, J. M.; Zennamo, J.; Zhao, T. G.; Zhou, B.; Zhu, J.; Zielinski, M.; Zieminska, D.; Zivkovic, L.

    2014-06-01

    The electron and photon reconstruction and identification algorithms used by the D0 Collaboration at the Fermilab Tevatron collider are described. The determination of the electron energy scale and resolution is presented. Studies of the performance of the electron and photon reconstruction and identification are summarized.

  9. Dependence of alanine gel dosimeter response as a function of photon clinical beams dose rate

    International Nuclear Information System (INIS)

    Silva, Cleber Feijo; Campos, Leticia Lucente

    2013-01-01

    Gel dosimetry is a new area developed by Gore, it is ery useful for application in radiotherapy because using NMR imaging as evaluation technique is possible to evaluate three dimensional absorbed dose distribution. The measure technique is based on difference of ferrous (Fe 2+ ) and ferric (Fe 3+ ) ) ions concentration that can be measured also by spectrophotometry technique. The Alanine gel dosimeter was developed at IPEN. The alanine is an amino acid and tissue equivalent material that presents significant improvement on previous alanine dosimetry systems. The addition of Alanine increases the production of ferric ions in the solution. This work aims to study the dose rate dependence of photon clinical beams radiation on the alanine gel dosimeter optical response, as well as the response repeatability and gel production reproducibility, since this property is very important for characterization and standardization of any dosimeter. (author)

  10. Progress in electronics and photonics with nanomaterials

    DEFF Research Database (Denmark)

    Mishra, Yogendra Kumar; Murugan, Arul; Kotakoski, Jani

    2017-01-01

    Nanomaterials have been at the center of attraction for almost five decades as their contributions to different disciplines such as electronics, photonics and medicine are enormous. Various kinds of nanomaterials have been developed and are currently utilized in innumerable applications....... Nevertheless, their simple realization and easy and efficient upscaling are topics under intense investigation. Innovative strategies have been adopted for nanomaterial synthesis and their usability. Here, we provide a brief overview on nanomaterials ranging from basic understanding of their structure......-property relationship to advanced applications. This editorial covers various aspects about nanomaterials, which will be useful/attractive for beginners in the field of nanotechnology as well as for experts and for industrialists looking forward to exploit them for real world applications....

  11. Photon and electron identification with the ATLAS detector

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00431162; The ATLAS collaboration

    2016-01-01

    The identification of prompt photons and the rejection of background, originating mostly from photons from hadron decays, relies on the high granularity of the ATLAS calorimeter. The electron identification is based on a likelihood discriminant to separate isolated electron from background electron originating from photon conversions, hadron misidentification and heavy flavour decays. Additionally, isolation variables provide further handles to separate signal and background. The measurements of the efficiencies of the electron and photon identification and isolation selections are performed with data. Tag and probe techniques are used with Z$\\rightarrow$ee, J/$\\psi$ $\\rightarrow$ee and Z$\\rightarrow$l l$\\gamma$ decays. Inclusive photon samples are also used to measure photon identification efficiency.\\\\ The results of these measurement with the pp collisions data recorded in 2015 at $\\sqrt {s}$ = 13 TeV, corresponding to an integrated luminosity of 3.2 fb$^{-1}$, are presented. as well as a first look at 201...

  12. Inelastic electron photon scattering at moderate four momentum transfers

    International Nuclear Information System (INIS)

    Berger, C.; Genzel, H.; Grigull, R.; Lackas, W.; Raupach, F.; Klovning, A.; Lillestoel, E.; Skard, J.A.; Ackermann, H.; Buerger, J.

    1980-10-01

    We present new high statistics data on hadron production in photon photon reactions. The data are analyzed in terms of an electron photon scattering formalism. The dependence of the total cross section on Q 2 , the four momentum transfer squared of the scattered electron, and on the mass W of the hadronic system is investigated. The data are compared to predictions from Vector Dominance and the quark model. (orig.)

  13. Electron and photon identification in the D0 experiment

    Czech Academy of Sciences Publication Activity Database

    Abazov, V. M.; Abbott, B.; Acharya, B.S.; Kupčo, Alexander; Lokajíček, Miloš

    Roč. 750, Jun ( 2014 ), s. 78-95 ISSN 0168-9002 R&D Projects: GA MŠk(CZ) LG12006 Institutional support: RVO:68378271 Keywords : electron and photon reconstruction * electron and photon identification * Tevatron Run II * D0 * DZero * Fermilab Subject RIV: BF - Elementary Particles and High Energy Physics Impact factor: 1.216, year: 2014

  14. Dosimetric Evaluation of Linac Photon Small Fields using MAGIC Polymer Gels

    Directory of Open Access Journals (Sweden)

    Hossein Hasani

    2011-09-01

    ionization chambers has limitations regarding uncertainty, due to the relatively large sizes of ionization chambers with respect to small field sizes and the lack of charged-particle equilibrium in such small fields. Pinpoint chambers are too large for very small photon fields and smaller dosimeters should be used. Fewer limitations in the dosimetry of small fields exist when using polymer gel dosimeters. Hence polymer gel dosimeters are suitable for dosimetry of photon small fields.

  15. Sol–Gel-Derived Glass-Ceramic Photorefractive Films for Photonic Structures

    Directory of Open Access Journals (Sweden)

    Anna Lukowiak

    2017-02-01

    Full Text Available Glass photonics are widespread, from everyday objects around us to high-tech specialized devices. Among different technologies, sol–gel synthesis allows for nanoscale materials engineering by exploiting its unique structures, such as transparent glass-ceramics, to tailor optical and electromagnetic properties and to boost photon-management yield. Here, we briefly discuss the state of the technology and show that the choice of the sol–gel as a synthesis method brings the advantage of process versatility regarding materials composition and ease of implementation. In this context, we present tin-dioxide–silica (SnO2–SiO2 glass-ceramic waveguides activated by europium ions (Eu3+. The focus is on the photorefractive properties of this system because its photoluminescence properties have already been discussed in the papers presented in the bibliography. The main findings include the high photosensitivity of sol–gel 25SnO2:75SiO2 glass-ceramic waveguides; the ultraviolet (UV-induced refractive index change (Δn ~ −1.6 × 10−3, the easy fabrication process, and the low propagation losses (0.5 ± 0.2 dB/cm, that make this glass-ceramic an interesting photonic material for smart optical applications.

  16. Ordered materials for organic electronics and photonics.

    Science.gov (United States)

    O'Neill, Mary; Kelly, Stephen M

    2011-02-01

    We present a critical review of semiconducting/light emitting, liquid crystalline materials and their use in electronic and photonic devices such as transistors, photovoltaics, OLEDs and lasers. We report that annealing from the mesophase improves the order and packing of organic semiconductors to produce state-of-the-art transistors. We discuss theoretical models which predict how charge transport and light emission is affected by the liquid crystalline phase. Organic photovoltaics and OLEDs require optimization of both charge transport and optical properties and we identify the various trade-offs involved for ordered materials. We report the crosslinking of reactive mesogens to give pixellated full-colour OLEDs and distributed bi-layer photovoltaics. We show how the molecular organization inherent to the mesophase can control the polarization of light-emitting devices and the gain in organic, thin-film lasers and can also provide distributed feedback in chiral nematic mirrorless lasers. We update progress on the surface alignment of liquid crystalline semiconductors to obtain monodomain devices without defects or devices with spatially varying properties. Finally the significance of all of these developments is assessed. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Transition radiation and coherent electron-photon scattering

    International Nuclear Information System (INIS)

    Moran, M.J.

    1985-04-01

    Relativistic electron irradiation of thin solid targets is known to generate collimated beams of x-ray photons in the forward direction by a number of different processes. A variety of mechanisms are discussed that share common characteristics in the angular and spectral distributions of the generated photon beams. Some simple physical explanations are offered for the characteristics shared by these processes. Some examples are then given based on experimental results attained at the LLNL electron-positron accelerator

  18. Photon-induced near-field electron microscopy.

    Science.gov (United States)

    Barwick, Brett; Flannigan, David J; Zewail, Ahmed H

    2009-12-17

    In materials science and biology, optical near-field microscopies enable spatial resolutions beyond the diffraction limit, but they cannot provide the atomic-scale imaging capabilities of electron microscopy. Given the nature of interactions between electrons and photons, and considering their connections through nanostructures, it should be possible to achieve imaging of evanescent electromagnetic fields with electron pulses when such fields are resolved in both space (nanometre and below) and time (femtosecond). Here we report the development of photon-induced near-field electron microscopy (PINEM), and the associated phenomena. We show that the precise spatiotemporal overlap of femtosecond single-electron packets with intense optical pulses at a nanostructure (individual carbon nanotube or silver nanowire in this instance) results in the direct absorption of integer multiples of photon quanta (nhomega) by the relativistic electrons accelerated to 200 keV. By energy-filtering only those electrons resulting from this absorption, it is possible to image directly in space the near-field electric field distribution, obtain the temporal behaviour of the field on the femtosecond timescale, and map its spatial polarization dependence. We believe that the observation of the photon-induced near-field effect in ultrafast electron microscopy demonstrates the potential for many applications, including those of direct space-time imaging of localized fields at interfaces and visualization of phenomena related to photonics, plasmonics and nanostructures.

  19. Photon gating in four-dimensional ultrafast electron microscopy.

    Science.gov (United States)

    Hassan, Mohammed T; Liu, Haihua; Baskin, John Spencer; Zewail, Ahmed H

    2015-10-20

    Ultrafast electron microscopy (UEM) is a pivotal tool for imaging of nanoscale structural dynamics with subparticle resolution on the time scale of atomic motion. Photon-induced near-field electron microscopy (PINEM), a key UEM technique, involves the detection of electrons that have gained energy from a femtosecond optical pulse via photon-electron coupling on nanostructures. PINEM has been applied in various fields of study, from materials science to biological imaging, exploiting the unique spatial, energy, and temporal characteristics of the PINEM electrons gained by interaction with a "single" light pulse. The further potential of photon-gated PINEM electrons in probing ultrafast dynamics of matter and the optical gating of electrons by invoking a "second" optical pulse has previously been proposed and examined theoretically in our group. Here, we experimentally demonstrate this photon-gating technique, and, through diffraction, visualize the phase transition dynamics in vanadium dioxide nanoparticles. With optical gating of PINEM electrons, imaging temporal resolution was improved by a factor of 3 or better, being limited only by the optical pulse widths. This work enables the combination of the high spatial resolution of electron microscopy and the ultrafast temporal response of the optical pulses, which provides a promising approach to attain the resolution of few femtoseconds and attoseconds in UEM.

  20. Infusing photonics to increase enrollment in electronics engineering technology

    Science.gov (United States)

    Panayiotou, Chrys A.; Seeber, Fred P.

    2007-06-01

    During the last 15 years most of the electronics engineering technology programs across the nation have experienced a constant decline in enrollment. Today's high school students do not seem to consider a career in electronics engineering appealing enough to commit to a field of study in desperate need of new students. They still associate electronics programs with the electronics section of a department store; televisions, stereo systems, DVD and VCR players, and other disposable electronics. While the downward trend continues across the nation, Indian River Community College (IRCC) has been able not only to stop it but to reverse it by attracting a new generation of students. By introducing high school students to new and emerging technologies, their perception of established degrees has changed and their interest has been stimulated. Photonics is one of those technologies capturing students' attention. IRCC, a partner college in the National Center for Optics and Photonics Education (OP-TEC), with the assistance of other colleges like Camden County College which already offers an Associate in Applied Science degree in Photonics, has created a Photonics specialization under the Electronics Engineering Technology program. The targeted marketing of this new specialization has led to an increase in enrollment of 50% in 2005, 80% in 2006, and for 2007 it is projected it to be over 100%. An interesting comparison can be made concerning enrollment at colleges with a full AAS program in photonics like Camden County College and IRCC which uses photonics as an enabling technology. This analysis could lead to a new approach in restructuring engineering technology degrees with the infusion of photonics throughout many technology fields. This presentation will discuss the plan of action that made possible this initiative at Indian River Community College and new program directions at Camden County College, Blackwood, New Jersey.

  1. Experimental Study of Electronic Quantum Interference, Photonic Crystal Cavity, Photonic Band Edge Effects for Optical Amplification

    Science.gov (United States)

    2016-01-26

    EDGE EFFECTS FOR OPTICAL AMPLIFICATION Shawn-Yu Lin Rensselaer Polytechnic Institute 110 8th Street Troy, New York 12180 26 Jan 2016 Final Report...2014 – 11 Jan 2016 4. TITLE AND SUBTITLE Experimental Study of Electronic Quantum Interference, Photonic Crystal Cavity, Photonic Band Edge Effects...Approved for public release; distribution is unlimited. i Approved for public release; distribution is unlimited. Table of Contents 1.0 Summary

  2. Transparent Glass-Ceramics Produced by Sol-Gel: A Suitable Alternative for Photonic Materials

    Directory of Open Access Journals (Sweden)

    Giulio Gorni

    2018-01-01

    Full Text Available Transparent glass-ceramics have shown interesting optical properties for several photonic applications. In particular, compositions based on oxide glass matrices with fluoride crystals embedded inside, known as oxyfluoride glass-ceramics, have gained increasing interest in the last few decades. Melt-quenching is still the most used method to prepare these materials but sol-gel has been indicated as a suitable alternative. Many papers have been published since the end of the 1990s, when these materials were prepared by sol-gel for the first time, thus a review of the achievements obtained so far is necessary. In the first part of this paper, a review of transparent sol-gel glass-ceramics is made focusing mainly on oxyfluoride compositions. Many interesting optical results have been obtained but very little innovation of synthesis and processing is found with respect to pioneering papers published 20 years ago. In the second part we describe the improvements in synthesis and processing obtained by the authors during the last five years. The main achievements are the preparation of oxyfluoride glass-ceramics with a much higher fluoride crystal fraction, at least double that reported up to now, and the first synthesis of NaGdF4 glass-ceramics. Moreover, a new SiO2 precursor was introduced in the synthesis, allowing for a reduction in the treatment temperature and favoring hydroxyl group removal. Interesting optical properties demonstrated the incorporation of dopant ions in the fluoride crystals, thus obtaining crystal-like spectra along with higher efficiencies with respect to xerogels, and hence demonstrating that these materials are a suitable alternative for photonic applications.

  3. Transparent Glass-Ceramics Produced by Sol-Gel: A Suitable Alternative for Photonic Materials

    Science.gov (United States)

    Gorni, Giulio; Mosa, Jadra; Balda, Rolindes; Fernández, Joaquin; Durán, Alicia; Castro, Yolanda

    2018-01-01

    Transparent glass-ceramics have shown interesting optical properties for several photonic applications. In particular, compositions based on oxide glass matrices with fluoride crystals embedded inside, known as oxyfluoride glass-ceramics, have gained increasing interest in the last few decades. Melt-quenching is still the most used method to prepare these materials but sol-gel has been indicated as a suitable alternative. Many papers have been published since the end of the 1990s, when these materials were prepared by sol-gel for the first time, thus a review of the achievements obtained so far is necessary. In the first part of this paper, a review of transparent sol-gel glass-ceramics is made focusing mainly on oxyfluoride compositions. Many interesting optical results have been obtained but very little innovation of synthesis and processing is found with respect to pioneering papers published 20 years ago. In the second part we describe the improvements in synthesis and processing obtained by the authors during the last five years. The main achievements are the preparation of oxyfluoride glass-ceramics with a much higher fluoride crystal fraction, at least double that reported up to now, and the first synthesis of NaGdF4 glass-ceramics. Moreover, a new SiO2 precursor was introduced in the synthesis, allowing for a reduction in the treatment temperature and favoring hydroxyl group removal. Interesting optical properties demonstrated the incorporation of dopant ions in the fluoride crystals, thus obtaining crystal-like spectra along with higher efficiencies with respect to xerogels, and hence demonstrating that these materials are a suitable alternative for photonic applications. PMID:29385706

  4. Transparent Glass-Ceramics Produced by Sol-Gel: A Suitable Alternative for Photonic Materials.

    Science.gov (United States)

    Gorni, Giulio; Velázquez, Jose J; Mosa, Jadra; Balda, Rolindes; Fernández, Joaquin; Durán, Alicia; Castro, Yolanda

    2018-01-30

    Transparent glass-ceramics have shown interesting optical properties for several photonic applications. In particular, compositions based on oxide glass matrices with fluoride crystals embedded inside, known as oxyfluoride glass-ceramics, have gained increasing interest in the last few decades. Melt-quenching is still the most used method to prepare these materials but sol-gel has been indicated as a suitable alternative. Many papers have been published since the end of the 1990s, when these materials were prepared by sol-gel for the first time, thus a review of the achievements obtained so far is necessary. In the first part of this paper, a review of transparent sol-gel glass-ceramics is made focusing mainly on oxyfluoride compositions. Many interesting optical results have been obtained but very little innovation of synthesis and processing is found with respect to pioneering papers published 20 years ago. In the second part we describe the improvements in synthesis and processing obtained by the authors during the last five years. The main achievements are the preparation of oxyfluoride glass-ceramics with a much higher fluoride crystal fraction, at least double that reported up to now, and the first synthesis of NaGdF₄ glass-ceramics. Moreover, a new SiO₂ precursor was introduced in the synthesis, allowing for a reduction in the treatment temperature and favoring hydroxyl group removal. Interesting optical properties demonstrated the incorporation of dopant ions in the fluoride crystals, thus obtaining crystal-like spectra along with higher efficiencies with respect to xerogels, and hence demonstrating that these materials are a suitable alternative for photonic applications.

  5. electron-positron-photon plasma around a collapsing star

    OpenAIRE

    Ruffini, R.; Vitagliano, L.; Xue, S. -S.

    2003-01-01

    We describe electron-positron pairs creation around an electrically charged star core collapsing to an electromagnetic black hole (EMBH), as well as pairs annihilation into photons. We use the kinetic Vlasov equation formalism for the pairs and photons and show that a regime of plasma oscillations is established around the core. As a byproduct of our analysis we can provide an estimate for the thermalization time scale.

  6. Electron and photon energy measurement calibration with the ATLAS detector

    CERN Document Server

    Manzoni, Stefano; The ATLAS collaboration

    2016-01-01

    An accurate calibration of the energy measurement of electron and photon is paramount for many ATLAS physics analysis. The calibration of the energy measurement is performed in-situ using a large statistics of Z->ee events. The results obtained with the pp collisions data recorded in 2015 and 2016 at sqrt(s)= 13 TeV, corresponding to an integrated luminosity of 3.2 fb-1 and 2.7 fb-1 respectively , as well as the corresponding uncertainties on the electron and photon energy scales, are presented.

  7. Electron and photon energy measurement calibration with the ATLAS detector

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00436885; The ATLAS collaboration

    2016-01-01

    An accurate calibration of the energy measurement of electrons and photons is paramount for many ATLAS physics analyses. The calibration of the energy measurement is performed $in$-$situ$ using a large statistics of $Z \\rightarrow ee$ events. The results obtained with the $pp$ collisions data recorded in 2015 and 2016 at $\\sqrt{s}=13$ TeV, corresponding to an integrated luminosity of 3.2 fb$^{-1}$ and 2.7 fb$^{-1}$ respectively, as well as the corresponding uncertainties on the electron and photon energy scales, are presented

  8. First observation of two-electron one-photon transitions in single-photon K-shell double ionization.

    Science.gov (United States)

    Hoszowska, J; Dousse, J-Cl; Szlachetko, J; Kayser, Y; Cao, W; Jagodziński, P; Kavčič, M; Nowak, S H

    2011-07-29

    Experimental evidence for the correlated two-electron one-photon transitions (1s(-2)→2s(-1)2p(-1)) following single-photon K-shell double ionization is reported. The double K-shell vacancy states in solid Mg, Al, and Si were produced by means of monochromatized synchrotron radiation, and the two-electron one-photon radiative transitions were observed by using a wavelength dispersive spectrometer. The two-electron one-photon transition energies and the branching ratios of the radiative one-electron to two-electron transitions were determined and compared to available perturbation theory predictions and configuration interaction calculations.

  9. Monitoring Electron-Photon Dressing in WSe2.

    Science.gov (United States)

    De Giovannini, Umberto; Hübener, Hannes; Rubio, Angel

    2016-12-14

    Optical pumping of solids creates a nonequilibrium electronic structure where electrons and photons combine to form quasiparticles of dressed electronic states. The resulting shift of electronic levels is known as the optical Stark effect, visible as a red shift in the optical spectrum. Here we show that in a pump-probe setup we can uniquely define a nonequilibrium quasiparticle bandstructure that can be directly measurable with photoelectron spectroscopy. The dynamical photon-dressing (and undressing) of the many-body electronic states can be monitored by pump-probe time and angular-resolved photoelectron spectroscopy (tr-ARPES) as the photon-dressed bandstructure evolves in time depending on the pump-probe pulse overlap. The computed tr-ARPES spectrum agrees perfectly with the quasi-energy spectrum of Floquet theory at maximum overlap and goes to the equilibrium bandstructure as the pump-probe overlap goes to zero. Additionally, we show how this time-dependent nonequilibrium quasiparticle structure can be understood to be the bandstructure underlying the optical Stark effect. The extension to spin-resolved ARPES can be used to predict asymmetric dichroic response linked to the valley selective optical excitations in monolayer transition metal dichalcogenides (TMDs). These results establish the photon dressed nonequilibrium bandstructures as the underlying quasiparticle structure of light-driven steady-state quantum phases of matter.

  10. Computational methods of electron/photon transport

    International Nuclear Information System (INIS)

    Mack, J.M.

    1983-01-01

    A review of computational methods simulating the non-plasma transport of electrons and their attendant cascades is presented. Remarks are mainly restricted to linearized formalisms at electron energies above 1 keV. The effectiveness of various metods is discussed including moments, point-kernel, invariant imbedding, discrete-ordinates, and Monte Carlo. Future research directions and the potential impact on various aspects of science and engineering are indicated

  11. Development of photonic crystals using sol-gel process for high power laser applications

    International Nuclear Information System (INIS)

    Benoit, Florence

    2015-01-01

    Three-dimensional photonic crystals (PCs) are periodic materials with a modulated refractive index on a length scale close to the light wavelength. This optical property allows the preparation of specific optical components like highly reflective mirrors. Moreover, these structured materials might have a high laser-induced damage threshold (LIDT) in the sub-nanosecond range compared to multilayered dielectric mirrors. This property is obtained because only one high LIDT material (silica) is used. In this work, we present the development of 3D PCs with narrow-sized colloidal silica particles, prepared by sol-gel process and deposited with Langmuir-Blodgett technique. Different syntheses routes have been investigated and compared regarding the optical properties of the PCs. A numerical model based on an ideal opal network including defect influence is used to explain these experimental results. (author) [fr

  12. Simultaneous optimization of photons and electrons for mixed beam radiotherapy.

    Science.gov (United States)

    Mueller, S; Fix, M K; Joosten, A; Henzen, D; Frei, D; Volken, W; Kueng, R; Aebersold, D M; Stampanoni, M F M; Manser, P

    2017-06-26

    The aim of this work is to develop and investigate an inverse treatment planning process (TPP) for mixed beam radiotherapy (MBRT) capable of performing simultaneous optimization of photon and electron apertures. A simulated annealing based direct aperture optimization (DAO) is implemented to perform simultaneous optimization of photon and electron apertures, both shaped with the photon multileaf collimator (pMLC). Validated beam models are used as input for Monte Carlo dose calculations. Consideration of photon pMLC transmission during DAO and a weight re-optimization of the apertures after deliverable dose calculation are utilized to efficiently reduce the differences between optimized and deliverable dose distributions. The TPP for MBRT is evaluated for an academic situation with a superficial and an enlarged PTV in the depth, a left chest wall case including the internal mammary chain and a squamous cell carcinoma case. Deliverable dose distributions of MBRT plans are compared to those of modulated electron radiotherapy (MERT), photon IMRT and if available to those of clinical VMAT plans. The generated MBRT plans dosimetrically outperform the MERT, photon IMRT and VMAT plans for all investigated situations. For the clinical cases of the left chest wall and the squamous cell carcinoma, the MBRT plans cover the PTV similarly or more homogeneously than the VMAT plans, while OARs are spared considerably better with average reductions of the mean dose to parallel OARs and D 2% to serial OARs by 54% and 26%, respectively. Moreover, the low dose bath expressed as V 10% to normal tissue is substantially reduced by up to 45% compared to the VMAT plans. A TPP for MBRT including simultaneous optimization is successfully implemented and the dosimetric superiority of MBRT plans over MERT, photon IMRT and VMAT plans is demonstrated for academic and clinical situations including superficial targets with and without deep-seated part.

  13. Simultaneous optimization of photons and electrons for mixed beam radiotherapy

    Science.gov (United States)

    Mueller, S.; Fix, M. K.; Joosten, A.; Henzen, D.; Frei, D.; Volken, W.; Kueng, R.; Aebersold, D. M.; Stampanoni, M. F. M.; Manser, P.

    2017-07-01

    The aim of this work is to develop and investigate an inverse treatment planning process (TPP) for mixed beam radiotherapy (MBRT) capable of performing simultaneous optimization of photon and electron apertures. A simulated annealing based direct aperture optimization (DAO) is implemented to perform simultaneous optimization of photon and electron apertures, both shaped with the photon multileaf collimator (pMLC). Validated beam models are used as input for Monte Carlo dose calculations. Consideration of photon pMLC transmission during DAO and a weight re-optimization of the apertures after deliverable dose calculation are utilized to efficiently reduce the differences between optimized and deliverable dose distributions. The TPP for MBRT is evaluated for an academic situation with a superficial and an enlarged PTV in the depth, a left chest wall case including the internal mammary chain and a squamous cell carcinoma case. Deliverable dose distributions of MBRT plans are compared to those of modulated electron radiotherapy (MERT), photon IMRT and if available to those of clinical VMAT plans. The generated MBRT plans dosimetrically outperform the MERT, photon IMRT and VMAT plans for all investigated situations. For the clinical cases of the left chest wall and the squamous cell carcinoma, the MBRT plans cover the PTV similarly or more homogeneously than the VMAT plans, while OARs are spared considerably better with average reductions of the mean dose to parallel OARs and D 2% to serial OARs by 54% and 26%, respectively. Moreover, the low dose bath expressed as V 10% to normal tissue is substantially reduced by up to 45% compared to the VMAT plans. A TPP for MBRT including simultaneous optimization is successfully implemented and the dosimetric superiority of MBRT plans over MERT, photon IMRT and VMAT plans is demonstrated for academic and clinical situations including superficial targets with and without deep-seated part.

  14. Water equivalence of polymer gel dosimeters

    International Nuclear Information System (INIS)

    Sellakumar, P.; James Jebaseelan Samuel, E.; Supe, Sanjay S.

    2007-01-01

    To evaluate the water equivalence and radiation transport properties of polymer gel dosimeters over the wide range of photon and electron energies 14 different types of polymer gels were considered. Their water equivalence was evaluated in terms of effective atomic number (Z eff ), electron density (ρ e ), photon mass attenuation coefficient (μ/ρ), photon mass energy absorption coefficient (μ en /ρ) and total stopping power (S/ρ) tot of electrons using the XCOM and the ESTAR database. The study showed that the effective atomic number of polymer gels were very close ( en /ρ for all polymer gels were in close agreement ( tot of electrons in polymer gel dosimeters were within 1% agreement with that of water. From the study we conclude that at lower energy (<80keV) the polymer gel dosimeters cannot be considered water equivalent and study has to be carried out before using the polymer gel for clinical application

  15. FTL Quantum Models of the Photon and the Electron

    International Nuclear Information System (INIS)

    Gauthier, Richard F.

    2007-01-01

    A photon is modeled by an uncharged superluminal quantum moving at 1.414c along an open 45-degree helical trajectory with radius R = λ/2π (where λ is the helical pitch or wavelength). A mostly superluminal spatial model of an electron is composed of a charged pointlike quantum circulating at an extremely high frequency ( 2.5 x 1020 hz) in a closed, double-looped hehcal trajectory whose helical pitch is one Compton wavelength h/mc. The quantum has energy and momentum but not rest mass, so its speed is not limited by c. sThe quantum's speed is superluminal 57% of the time and subluminal 43% of the time, passing through c twice in each trajectory cycle. The quantum's maximum speed in the electron's rest frame is 2.515c and its minimum speed is .707c. The electron model's helical trajectory parameters are selected to produce the electron's spin (ℎ/2π)/2 and approximate (without small QED corrections) magnetic moment e(ℎ/2π)/2m (the Bohr magneton μB) as well as its Dirac equation-related 'jittery motion' angular frequency 2mc2/(ℎ/2π), amplitude (ℎ/2π)/2mc and internal speed c. The two possible helicities of the electron model correspond to the electron and the positron. With these models, an electron is like a closed circulating photon. The electron's inertia is proposed to be related to the electron model's circulating internal Compton momentum mc. The internal superluminalily of the photon model, the internal superluminahty/subluminality of the electron model, and the proposed approach to the electron's inertia as ''momentum at rest'' within the electron, could be relevant to possible mechanisms of superluminal communication and transportation

  16. Electron/Photon Verification Calculations Using MCNP4B

    Energy Technology Data Exchange (ETDEWEB)

    D. P. Gierga; K. J. Adams

    1999-04-01

    MCNP4BW was released in February 1997 with significant enhancements to electron/photon transport methods. These enhancements have been verified against a wide range of published electron/photon experiments, spanning high energy bremsstrahlung production to electron transmission and reflection. The impact of several MCNP tally options and physics parameters was explored in detail. The agreement between experiment and simulation was usually within two standard deviations of the experimental and calculational errors. Furthermore, sub-step artifacts for bremsstrahlung production were shown to be mitigated. A detailed suite of electron depth dose calculations in water is also presented. Areas for future code development have also been explored and include the dependence of cell and detector tallies on different bremsstrahlung angular models and alternative variance reduction splitting schemes for bremsstrahlung production.

  17. Convergence of Photonics and Electronics for Terahertz Wireless Communications

    DEFF Research Database (Denmark)

    Salazar, Adrian Ruiz; Rommel, Simon; Anufriyev, E.

    2016-01-01

    Terahertz wireless communications are expected to offer the required high capacity and low latency performance necessary for short-range wireless access and control applications. We present an overview of some the activities in this area in the newly started H2020 ITN project CELTA: Convergence o...... of Electronics and Photonics Technologies Enabling Terahertz Applications....

  18. On the scalar electron mass limit from single photon experiments

    International Nuclear Information System (INIS)

    Grivaz, J.F.

    1987-03-01

    We discuss how the 90% C.L. lower limit on the mass of the scalar electron, as extracted from the single photon experiments, is affected by the way the background from radiative neutrino pair production is handled. We argue that some of the results presented at the Berkeley conference are overoptimistic, and that the mass lower limit is 65 GeV rather than the advertized value of 84 GeV, for the case of degenerate scalar electrons with massless photinos

  19. Structural dynamics of electronic and photonic systems

    CERN Document Server

    Suhir, Ephraim; Steinberg, David S

    2011-01-01

    The proposed book will offer comprehensive and versatile methodologies and recommendations on how to determine dynamic characteristics of typical micro- and opto-electronic structural elements (printed circuit boards, solder joints, heavy devices, etc.) and how to design a viable and reliable structure that would be able to withstand high-level dynamic loading. Particular attention will be given to portable devices and systems designed for operation in harsh environments (such as automotive, aerospace, military, etc.)  In-depth discussion from a mechanical engineer's viewpoint will be conducte

  20. ENERGETIC PHOTON AND ELECTRON INTERACTIONS WITH POSITIVE IONS

    Energy Technology Data Exchange (ETDEWEB)

    Phaneuf, Ronald A. [UNR

    2013-07-01

    The objective of this research is a deeper understanding of the complex multi-electron interactions that govern inelastic processes involving positive ions in plasma environments, such as those occurring in stellar cares and atmospheres, x-ray lasers, thermonuclear fusion reactors and materials-processing discharges. In addition to precision data on ionic structure and transition probabilities, high resolution quantitative measurements of ionization test the theoretical methods that provide critical input to computer codes used for plasma modeling and photon opacity calculations. Steadily increasing computational power and a corresponding emphasis on simulations gives heightened relevance to precise and accurate benchmark data. Photons provide a highly selective probe of the internal electronic structure of atomic and molecular systems, and a powerful means to better understand more complex electron-ion interactions.

  1. A modified Fricke gel dosimeter for fast electron blood dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Del Lama, L.S., E-mail: lucasdellama@gmail.com [Departamento de Fsica, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo (FFCLRP/USP), Av. Bandeirantes, 3900, CEP 14040-901, Bairro Monte Alegre, Ribeirão Preto, São Paulo (Brazil); Góes, E.G. de [Instituto de Matemática, Estatística e Física, Universidade Federal de Rio Grande (IMEF/FURG), Av. Itália, km 8, CEP 96201-900, Bairro Carreiros, Rio Grande, Rio Grande do Sul (Brazil); Sampaio, F.G.A.; Petchevist, P.C.D.; Almeida, A. de [Departamento de Fsica, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo (FFCLRP/USP), Av. Bandeirantes, 3900, CEP 14040-901, Bairro Monte Alegre, Ribeirão Preto, São Paulo (Brazil)

    2014-12-15

    It has been suggested for more than forty years that blood and blood components be irradiated before allogeneic transfusions for immunosuppressed patients in order to avoid the Transfusion-Associated Graft-versus-Host Disease (TA-GVHD). Whole blood, red blood cells, platelets and granulocytes may have viable T cells and should be irradiated before transfusion for different patient clinical conditions. According to international guides, absorbed doses from 25 up to 50 Gy should be delivered to the central middle plane of each blood bag. Although gamma and X-rays from radiotherapy equipments and dedicated cell irradiators are commonly used for this purpose, electron beams from Linear Accelerators (LINACs) could be used as well. In this work, we developed a methodology able to acquire dosimetric data from blood irradiations, especially after fast electrons exposures. This was achieved using a proposed Fricke Xylenol Gel (FXG{sub p}) dosimeter, which presents closer radiological characteristics (attenuation coefficients and stopping-powers) to the whole blood, as well as complete absorbed dose range linearity. The developed methodology and the FXG{sub p} dosimeter were also able to provide isodose curves and field profiles for the irradiated samples.

  2. A modified Fricke gel dosimeter for fast electron blood dosimetry

    International Nuclear Information System (INIS)

    Del Lama, L.S.; Góes, E.G. de; Sampaio, F.G.A.; Petchevist, P.C.D.; Almeida, A. de

    2014-01-01

    It has been suggested for more than forty years that blood and blood components be irradiated before allogeneic transfusions for immunosuppressed patients in order to avoid the Transfusion-Associated Graft-versus-Host Disease (TA-GVHD). Whole blood, red blood cells, platelets and granulocytes may have viable T cells and should be irradiated before transfusion for different patient clinical conditions. According to international guides, absorbed doses from 25 up to 50 Gy should be delivered to the central middle plane of each blood bag. Although gamma and X-rays from radiotherapy equipments and dedicated cell irradiators are commonly used for this purpose, electron beams from Linear Accelerators (LINACs) could be used as well. In this work, we developed a methodology able to acquire dosimetric data from blood irradiations, especially after fast electrons exposures. This was achieved using a proposed Fricke Xylenol Gel (FXG p ) dosimeter, which presents closer radiological characteristics (attenuation coefficients and stopping-powers) to the whole blood, as well as complete absorbed dose range linearity. The developed methodology and the FXG p dosimeter were also able to provide isodose curves and field profiles for the irradiated samples

  3. New limits on hidden photons from past electron beam dumps

    International Nuclear Information System (INIS)

    Andreas, Sarah; Niebuhr, Carsten; Ringwald, Andreas

    2012-09-01

    Hidden sectors with light extra U(1) gauge bosons, so called hidden photons, have recently attracted some attention because they are a common feature of physics beyond the Standard Model like string theory and SUSY and additionally are phenomenologically of great interest regarding recent astrophysical observations. The hidden photon is already constrained by various laboratory experiments and presently searched for in running as well as upcoming experiments. We summarize the current status of limits on hidden photons from past electron beam dump experiments including two new limits from such experiments at KEK and Orsay that have so far not been considered. All our limits take into account the experimental acceptances obtained from Monte Carlo simulations.

  4. New limits on hidden photons from past electron beam dumps

    Energy Technology Data Exchange (ETDEWEB)

    Andreas, Sarah; Niebuhr, Carsten; Ringwald, Andreas

    2012-09-15

    Hidden sectors with light extra U(1) gauge bosons, so called hidden photons, have recently attracted some attention because they are a common feature of physics beyond the Standard Model like string theory and SUSY and additionally are phenomenologically of great interest regarding recent astrophysical observations. The hidden photon is already constrained by various laboratory experiments and presently searched for in running as well as upcoming experiments. We summarize the current status of limits on hidden photons from past electron beam dump experiments including two new limits from such experiments at KEK and Orsay that have so far not been considered. All our limits take into account the experimental acceptances obtained from Monte Carlo simulations.

  5. Multidimensional electron-photon transport with standard discrete ordinates codes

    International Nuclear Information System (INIS)

    Drumm, C.R.

    1995-01-01

    A method is described for generating electron cross sections that are compatible with standard discrete ordinates codes without modification. There are many advantages of using an established discrete ordinates solver, e.g. immediately available adjoint capability. Coupled electron-photon transport capability is needed for many applications, including the modeling of the response of electronics components to space and man-made radiation environments. The cross sections have been successfully used in the DORT, TWODANT and TORT discrete ordinates codes. The cross sections are shown to provide accurate and efficient solutions to certain multidimensional electronphoton transport problems

  6. Multi-photon creation and single-photon annihilation of electron-positron pairs

    International Nuclear Information System (INIS)

    Hu, Huayu

    2011-01-01

    In this thesis we study multi-photon e + e - pair production in a trident process, and singlephoton e + e - pair annihilation in a triple interaction. The pair production is considered in the collision of a relativistic electron with a strong laser beam, and calculated within the theory of laser-dressed quantum electrodynamics. A regularization method is developed systematically for the resonance problem arising in the multi-photon process. Total production rates, positron spectra, and relative contributions of different reaction channels are obtained in various interaction regimes. Our calculation shows good agreement with existing experimental data from SLAC, and adds further insights into the experimental findings. Besides, we study the process in a manifestly nonperturbative domain, whose accessibility to future all-optical experiments based on laser acceleration is shown. In the single-photon e + e - pair annihilation, the recoil momentum is absorbed by a spectator particle. Various kinematic configurations of the three incoming particles are examined. Under certain conditions, the emitted photon exhibits distinct angular and polarization distributions which could facilitate the detection of the process. Considering an equilibrium relativistic e + e - plasma, it is found that the single-photon process becomes the dominant annihilation channel for plasma temperatures above 3 MeV. Multi-particle correlation effects are therefore essential for the e + e - dynamics at very high density. (orig.)

  7. Multi-photon creation and single-photon annihilation of electron-positron pairs

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Huayu

    2011-04-27

    In this thesis we study multi-photon e{sup +}e{sup -} pair production in a trident process, and singlephoton e{sup +}e{sup -} pair annihilation in a triple interaction. The pair production is considered in the collision of a relativistic electron with a strong laser beam, and calculated within the theory of laser-dressed quantum electrodynamics. A regularization method is developed systematically for the resonance problem arising in the multi-photon process. Total production rates, positron spectra, and relative contributions of different reaction channels are obtained in various interaction regimes. Our calculation shows good agreement with existing experimental data from SLAC, and adds further insights into the experimental findings. Besides, we study the process in a manifestly nonperturbative domain, whose accessibility to future all-optical experiments based on laser acceleration is shown. In the single-photon e{sup +}e{sup -} pair annihilation, the recoil momentum is absorbed by a spectator particle. Various kinematic configurations of the three incoming particles are examined. Under certain conditions, the emitted photon exhibits distinct angular and polarization distributions which could facilitate the detection of the process. Considering an equilibrium relativistic e{sup +}e{sup -} plasma, it is found that the single-photon process becomes the dominant annihilation channel for plasma temperatures above 3 MeV. Multi-particle correlation effects are therefore essential for the e{sup +}e{sup -} dynamics at very high density. (orig.)

  8. Primary dose in photon beams with lateral electron disequilibrium

    Energy Technology Data Exchange (ETDEWEB)

    Nizin, P.S. (Staten Island University Hospital, Department of Radiation Oncology, 475 Seaview Avenue, Staten Island, NY (USA)); Chang, X.S. (Joint Center for Radiation Therapy, Department of Radiation Therapy, Harvard Medical School, Boston, MA (USA))

    1991-07-01

    It is shown that in narrow monoenergetic photon beams under conditions of lateral electron disequilibrium, primary absorbed dose {ital P}({ital r}) is a simple function of beam radius {ital r} : {ital P}{sub ({ital r})}={ital P}{sub {lambda}}{center dot}(1{minus}{ital e}{sup {minus}{gamma}{center dot}{ital r}}), where {ital P}{sub {lambda}} is the primary dose in broad beams for which complete lateral electron equilibrium exists, and {gamma} depends on photon energy and absorbing medium. This formula was evaluated using Monte-Carlo-generated data for the primary dose in water from monoenergetic photons in the energy range from 2 to 8 MeV. The primary dose was studied in beams of radii 0.006 cm{lt}{ital r}{lt}5.0 cm and within the depth interval 0.5 cm{le}{ital d}{le}24 cm. It was concluded that the saturation equation above provides an accurate description of the primary dose from monoenergetic photon beams, as judged by comparison with Monte Carlo results.

  9. Mechanisms of EUV Exposure: Photons, Electrons and Holes

    Science.gov (United States)

    Narasimhan, Amrit

    The microelectronics industry's movement toward smaller and smaller feature sizes has necessitated a shift to Extreme Ultra-Violet (EUV) lithography to be able to pattern sub 20-nm features, much like earlier shifts from i-line to 248 nm. However, this shift from 193-nm lithography to EUV (13.5 nm) poses significant obstacles. EUV is the first optical lithography to operate in an energy range (92 eV per photon vs. 6.4 eV per photon for 193 nm lithography) above the electron binding energies of common resist atomic species. This significant energy increase complicates resist design. For exposures of equal dose, resists receive 14 times fewer photons in EUV relative to 193 nm. Thus, for EUV photoresists to be able to reap the benefits of smaller resolution they must also maximize absorption while still maintaining photo-reactivity. In order to design EUV resists for manufacturing, the first step is to understand the mechanisms of exposure involved in EUV photochemistry. In this Thesis, we present three studies performed to understand the behavior and reactivity of electrons and holes in chemically amplified photoresists. These three studies can be characterized by their approaches--computational and experimental, and serve to develop better resist models for EUV reactions and mechanisms. The first study discusses the adaptation and improvement of a Monte Carlo electron-resist simulation program to understand EUV photochemistry by modeling total electron yield, thickness loss, and sub-10 eV electron-resist interactions. The second study evaluates the mechanism of internal excitation as a possible pathway for acid generation in EUV resists by the investigation of electron-induced fluorescence. The third study aims to investigate the reactivity of electrons and holes in chemically amplified resists and determine their relative contributions to acid production.

  10. Electron and photon energy calibration with the ATLAS detector

    CERN Document Server

    Falke, Saskia; The ATLAS collaboration

    2017-01-01

    An accurate calibration of the energy measurement of electron and photon is needed for many ATLAS physics analysis. The calibration of the energy measurement is performed in-situ using a large statistics of Z->ee events. A pre-requisite of this calibration is a good understanding of the material in front of the calorimeter and of the inter-calibration of the different calorimeter layers. The Z->ee sample is also used to measure the energy resolution. The results obtained with the pp collisions data at sqrt(s)=13 TeV in 2016 (2015) corresponding to an integrated luminosity of 33.9 (3.1)fb-1 of sqrt(s)=13 TeV are presented as well as the corresponding uncertainties on the electron and photon energy scales.

  11. Electron and Photon Reconstruction and Identification with the ATLAS Detector

    International Nuclear Information System (INIS)

    Kuna, Marine

    2011-01-01

    This article presents the electron and photon reconstruction performance of the ATLAS detector based on the first LHC collision data at √(s)=7 TeV. Calorimetric and tracker related electron identification variables are in a fair agreement with the Monte Carlo model describing the detector response. The position of the reconstructed photon conversions vertices has been used to compare the description of the inner detector used in Monte Carlo geometry to that from data. The energy flow measured in the electromagnetic calorimeter has been used to provide the same comparison at larger radii. π 0 →γγ and J/Ψ→e + e - peaks were observed with reconstructed masses in good agreement with both Monte Carlo and PDG values. 17 W→eν candidates and one Z→e + e - candidate have been observed in 6.69 nb -1 of data.

  12. Micropatterning of Multiple Photonic Colloidal Crystal Gels for Flexible Structural Color Films.

    Science.gov (United States)

    Suzuki, Noriyuki; Iwase, Eiji; Onoe, Hiroaki

    2017-06-20

    We herein report the micropatterning of flexible multiple photonic colloidal crystal gels (PCCGs) using single-layered microchannels. These patterned PCCGs exhibit structural colors that can be tuned by adjustment of the diameter and concentration of the colloidal particles in precursor solutions of N-isopropylacrylamide (NIPAM) or polyethylene glycol diacrylate (PEGDA). The precursor solutions containing dispersed colloidal particles were selectively injected into single-layered microchannels where they polymerized rapidly. The shape, density, and height of the patterned PCCG pixels were determined by the microchannels, which in turn determined the optical properties of the PCCG arrays. Furthermore, the preparation of three different types of PCCGs exhibiting three different structural colors at a high pixel density was demonstrated successfully using the single-layered polydimethylsiloxane (PDMS) microchannels. Finally, the optical reflective properties and the mechanical flexibility of the patterned multiple PCCG arrays were evaluated. We expect that our method for the preparation of such patterned PCCG arrays will contribute to the development of flexible optical devices.

  13. Ionic conductivity study on electron beam irradiated polyacrylonitrile—polyethylene oxide gel

    International Nuclear Information System (INIS)

    Ma Yi-Zhun; Pang Li-Long; Zhu Ya-Bin; Wang Zhi-Guang; Shen Tie-Long

    2011-01-01

    Different mass percent polyacrylonitrile (PAN)—polyethylene oxide (PEO) gels were prepared and irradiated by an electron beam (EB) with energy of 1.0 MeV to the dose ranging from 13 kGy to 260 kGy. The gels were analysed by using Fourier transform infrared spectrum, gel fraction and ionic conductivity (IC) measurement. The results show that the gel is crosslinked by EB irradiation, the crosslinking degree rises with the increasing EB irradiation dose (ID) and the mass percents of both PAN and PEO contribute a lot to the crosslinking; in addition, EB irradiation can promote the IC of PAN—PEO gels. There exists an optimum irradiation dose, at which the IC can increase dramatically. The IC changes of the PAN—PEO gels along with ID are divided into three regions: IC rapidly increasing region, IC decreasing region and IC balanced region. The cause of the change can be ascribed to two aspects, gel capturing electron degree and crosslinking degree. By comparing the IC—ID curves of different mass percents of PAN and PEO in gel, we found that PAN plays a more important role for gel IC promotion than PEO, since addition of PAN in gel causes the IC—ID curve sharper, while addition of PEO in gel causes the curve milder. (interdisciplinary physics and related areas of science and technology)

  14. Large-time evolution of an electron in photon bath

    Energy Technology Data Exchange (ETDEWEB)

    Kazakov, Kirill A.; Nikitin, Vladimir V., E-mail: markiz4@yandex.ru

    2012-12-15

    The problem of infrared divergence of the effective electromagnetic field produced by elementary charges is revisited using the model of an electron freely evolving in a photon bath. It is shown that for any finite travel time, the effective field of the electron is infrared-finite, and that at each order of perturbation theory the radiative contributions grow unboundedly with time. Using the Schwinger-Keldysh formalism, factorization of divergent contributions in multi-loop diagrams is proved, and summation of the resulting infinite series is performed. It is found that despite the unbounded growth of individual contributions to the effective field, their sum is bounded, tending to zero in the limit of infinite travel time. It is concluded that the physical meaning of infrared singularity in the effective field is the existence of a peculiar irreversible spreading of electric charges, caused by their interaction with the electromagnetic field. This spreading originates from the quantum electromagnetic fluctuations, rather than the electron-photon scattering, and exists in vacuum as well as at finite temperatures. It shows itself in a damping of the off-diagonal elements of the momentum-space density matrix of electron, but does not affect its momentum probability distribution. This effect is discussed in terms of thermalization of the electron state, and the asymptotic growth of its quantum entropy is determined. Relationship of the obtained results to the Bloch-Nordsieck theorem is established and considered from the standpoint of measurability of the electromagnetic field. The effect of irreversible spreading on the electron diffraction in the classic two-slit experiment is determined, and is shown to be detectable in principle by modern devices already at room temperature. - Highlights: Black-Right-Pointing-Pointer Infrared finiteness of the effective electromagnetic field of a free electron is proved. Black-Right-Pointing-Pointer Quantum radiative effects

  15. Energy spectrum of Compton scattering of laser photons on relativistic electrons

    International Nuclear Information System (INIS)

    Ando, Hiroaki; Yoneda, Yasuharu

    1976-01-01

    The high energy photons in gamma-ray region are obtainable by the Compton scattering of laser photons on relativistic electrons. But the motion of the electrons in the storage ring is not necessarily uniform. In the study of the uneven effect, the energy distribution of scattered photons is derived from the assumed momentum distribution of incident electrons. It is generally impossible to derive the momentum distribution of incident electrons from the energy spectrum of scattered photons. The additional conditions which make this possible in a special case are considered. A calculational method is examined for deriving the energy spectrum of scattered photons from the assumed momentum distribution of incident electrons. (Mori, K.)

  16. Electron and Photon Reconstruction and Identification with the ATLAS Detector

    CERN Document Server

    Kuna, M; The ATLAS collaboration

    2011-01-01

    This article presents the electron and photon reconstruction performance in ATLAS with the first LHC collision data at $sqrt{s}$~=~7~TeV collected up to the beginning of June 2010. Calorimetric and tracker related electron identification variables are shown to be in a fair agreement with the Monte Carlo model. %Material estimations in the inner detector were checked with photon conversions vertex position, complementarily to the energy flow from minimum bias events for material at larger radii. The position of the reconstructed photon conversions vertices has been used to compare the inner detector model used in Monte Carlo to the real one from data. The energy flow measured in the electromagnetic calorimeter with minimum bias data has been used to provide the same comparison at larger radii. $pi^0 ightarrow gamma gamma$ and $J/Psi ightarrow ee$ peaks were observed with a reconstructed mass in good agreement with both Monte Carlo and PDG value. 17 $W ightarrow e u$ candidates and one $Z ightarrow ee$ candidat...

  17. Multidimensional electron-photon transport with standard discrete ordinates codes

    International Nuclear Information System (INIS)

    Drumm, C.R.

    1997-01-01

    A method is described for generating electron cross sections that are comparable with standard discrete ordinates codes without modification. There are many advantages of using an established discrete ordinates solver, e.g. immediately available adjoint capability. Coupled electron-photon transport capability is needed for many applications, including the modeling of the response of electronics components to space and man-made radiation environments. The cross sections have been successfully used in the DORT, TWODANT and TORT discrete ordinates codes. The cross sections are shown to provide accurate and efficient solutions to certain multidimensional electron-photon transport problems. The key to the method is a simultaneous solution of the continuous-slowing-down (CSD) portion and elastic-scattering portion of the scattering source by the Goudsmit-Saunderson theory. The resulting multigroup-Legendre cross sections are much smaller than the true scattering cross sections that they represent. Under certain conditions, the cross sections are guaranteed positive and converge with a low-order Legendre expansion

  18. Multidimensional electron-photon transport with standard discrete ordinates codes

    International Nuclear Information System (INIS)

    Drumm, C.R.

    1997-01-01

    A method is described for generating electron cross sections that are compatible with standard discrete ordinates codes without modification. There are many advantages to using an established discrete ordinates solver, e.g., immediately available adjoint capability. Coupled electron-photon transport capability is needed for many applications, including the modeling of the response of electronics components to space and synthetic radiation environments. The cross sections have been successfully used in the DORT, TWODANT, and TORT discrete ordinates codes. The cross sections are shown to provide accurate and efficient solutions to certain multidimensional electron-photon transport problems. The key to the method is a simultaneous solution of the continuous-slowing-down and elastic-scattering portions of the scattering source by the Goudsmit-Saunderson theory. The resulting multigroup-Legendre cross sections are much smaller than the true scattering cross sections that they represent. Under certain conditions, the cross sections are guaranteed positive and converge with a low-order Legendre expansion

  19. Dose characteristics of high-energy electrons, muons and photons

    International Nuclear Information System (INIS)

    Britvich, G.I.; Krupnyj, G.I.; Peleshko, V.N.; Rastsvetalov, Ya.N.

    1980-01-01

    Differential distribution of energy release at different depth of tissue-equivalent phantoms (plexiglas, polystyrene, polyethylene) at the energy of incident electrons, muons of 0.2-40 GeV and photons with the mean energy of 3.6 GeV are measured. The error of experimental results does not exceed 7%. On the basis of the data obtained dose characteristics of electrons, muons and photons for standard geometry are estimated. For all types of irradiation the maximum value of specific equivalent dose, nremxcm 2 /part. is presented. It is shown that published values of specific equivalent dose of electron radiation are higher in all the investigated energy range from 0.2 to 40 GeV, and for muon radiation a good agreement with the present experiment is observed. The highly precise results obtained which cover the wide dynamic range according to the energy of incident particles can serve as the basis for reconsidering the existing recommendations for dose characteristics of electron radiation [ru

  20. LDRD project 151362 : low energy electron-photon transport.

    Energy Technology Data Exchange (ETDEWEB)

    Kensek, Ronald Patrick; Hjalmarson, Harold Paul; Magyar, Rudolph J.; Bondi, Robert James; Crawford, Martin James

    2013-09-01

    At sufficiently high energies, the wavelengths of electrons and photons are short enough to only interact with one atom at time, leading to the popular %E2%80%9Cindependent-atom approximation%E2%80%9D. We attempted to incorporate atomic structure in the generation of cross sections (which embody the modeled physics) to improve transport at lower energies. We document our successes and failures. This was a three-year LDRD project. The core team consisted of a radiation-transport expert, a solid-state physicist, and two DFT experts.

  1. Electronic/photonic interfaces for ultrafast data processing.

    Energy Technology Data Exchange (ETDEWEB)

    Overberg, Mark E.; Geib, Kent Martin; Serkland, Darwin Keith; Hsu, Alan Yuan-Chun; Keeler, Gordon Arthur; Finnegan, Patrick Sean (LMATA Government Services, LLC, Albuquerque, NM)

    2008-09-01

    This report summarizes a 3-month program that explored the potential areas of impact for electronic/photonic integration technologies, as applied to next-generation data processing systems operating within 100+ Gb/s optical networks. The study included a technology review that targeted three key functions of data processing systems, namely receive/demultiplexing/clock recovery, data processing, and transmit/multiplexing. Various technical approaches were described and evaluated. In addition, we initiated the development of high-speed photodetectors and hybrid integration processes, two key elements of an ultrafast data processor. Relevant experimental results are described herein.

  2. Measurements of the Influence of Thermoplastic Mask in High Energy Photon Beams: Gel Dosimeter or Ionizing Chamber?

    Science.gov (United States)

    Moreira, M. V.; Petchevist, C. D.; de Almeida, A.

    2009-12-01

    The influence of the immobilization mask material on the absorbed dose distribution in patients exposed to radiotherapy treatment with photon beams has been investigated for photons from a 60Co source and a 6 MV Linac. Absorbed dose values have been inferred at different depths and in the build-up region. Dose measurements were obtained using Fricke Xylenol Gel dosimeter and the cylindrical PTW Freiburg TM 31016-0.016 cc ionizing micro chamber; their discrepancies are discussed. The affinities of FXG and PTW ICMicro for measurements with high energy photons and the difference in the effective atomic numbers due to their compositions are most likely the most important factors that contribute to the measured dose in the build-up region. The measured values show that the use of the mask material contributes to increase the absorbed doses near the surface of the tissue. The result also shows that the build-up effect for 60Co is significantly smaller than that for 6 MV photons; however, the variations noted in the final doses of the radiotherapic treatments with photons of high energy do not represent alterations in the total doses received by the patients submitted to the radiotherapy.

  3. Periodic nanostructures imprinted on high-temperature stable sol–gel films by ultraviolet-based nanoimprint lithography for photovoltaic and photonic applications

    Energy Technology Data Exchange (ETDEWEB)

    Back, Franziska [Schott AG, Research and Technology Development, Hattenbergstraße 10, 55122 Mainz (Germany); Fraunhofer-Institut für Silicatforschung ISC, Neunerplatz 2, 97082 Würzburg (Germany); Bockmeyer, Matthias; Rudigier-Voigt, Eveline [Schott AG, Research and Technology Development, Hattenbergstraße 10, 55122 Mainz (Germany); Löbmann, Peer [Fraunhofer-Institut für Silicatforschung ISC, Neunerplatz 2, 97082 Würzburg (Germany)

    2014-07-01

    Nanostructured sol–gel films with high-temperature stability are used in the area of electronics, photonics or biomimetic materials as light-trapping architectures in solar cells, displays, waveguides or as superhydrophobic surfaces with a lotus effect. In this work, high-temperature stable 2-μm nanostructured surfaces were prepared by ultraviolet-based nanoimprint lithography using an alkoxysilane binder incorporating modified silica nanoparticles. Material densification during thermal curing and microstructural evolution which are destined for a high structural fidelity of nanostructured films were investigated in relation to precursor chemistry, particle morphology and particle content of the imprint resist. The mechanism for densification and shrinkage of the films was clarified and correlated with the structural fidelity to explain the influence of the geometrical design on the optical properties. A high internal coherence of the microstructure of the nanostructured films results in a critical film thickness of > 5 μm. The structured glassy layers with high inorganic content show thermal stability up to 800 °C and have a high structural fidelity > 90% with an axial shrinkage of 16% and a horizontal shrinkage of 1%. This material allows the realization of highly effective light-trapping architectures for polycrystalline silicon thin-film solar cells on glass but also for the preparation of 2D photonic crystals for telecommunication wavelengths. - Highlights: • Fundamental research • Hybrid sol–gel material with high-temperature stability and contour accuracy • Ensuring of cost-efficient and industrially feasible processing • Application in photonic and photovoltaic.

  4. Probing few nucleon systems with photons and electrons

    International Nuclear Information System (INIS)

    Mukherjee, S.N.

    1988-01-01

    Several of the interesting radiative and electron scattering processes involving few nucleon systems at medium energies are discussed, with emphasis on what is interesting about the reaction, what is currently known both theoretically and experimentally, and what should be done next. One body systems yield fundamental particle properties, two-body (A = 2) systems fix the interaction between nucleons, and their couplings. The next goal is then to predict properties of A > 2 system in terms of dynamical theories whose parameters are determined by A ≤2 systems. Reactions with photons and electrons have been singled out because electromagnetic interaction is sufficiently well understood, it is weak and hence can be treated as perturbation. Failures to reproduce experimental results raises questions about the correctness of theoretical technique used, presence of three body forces and even to speculations that explicit quark degrees of freedom might be required. (author). 24 refs., 7 figs

  5. Design of Pixellated CMOS Photon Detector for Secondary Electron Detection in the Scanning Electron Microscope

    OpenAIRE

    Joon Huang Chuah; David Holburn

    2011-01-01

    This paper presents a novel method of detecting secondary electrons generated in the scanning electron microscope (SEM). The method suggests that the photomultiplier tube (PMT), traditionally used in the Everhart-Thornley (ET) detector, is to be replaced with a configurable multipixel solid-state photon detector offering the advantages of smaller dimension, lower supply voltage and power requirements, and potentially cheaper product cost. The design of the proposed detector has been implement...

  6. Dosimetric characterization of VIPARnd gel by optical analysis to high-energy photon beam used in external radiotherapy

    International Nuclear Information System (INIS)

    Dias, Juliana R.; Lima, Renata S.; Lopes, Roseany de V. Vieira; Ceschin, Artemis Marti

    2015-01-01

    Polymer gel dosimetry has been proposed as a possibility for measurements of dose distribution in radiotherapy. This work aims to evaluate the dosimetric characteristics of a VIPARnd for 6 MV photon beam used in radiotherapy using optical investigations. The absorbance spectrum of irradiated gel dosimeter was optical evaluated with spectrophotometer techniques and with CMOS camera readout for dose range of 0 to 50 Gy. Data shows that the VIPARnd has a maximum absorbance at 300 to 320 nm depending on the absorbed dose. The CMOS camera readouts were obtained in RGB color, the absorbance measurements suggest a major response of dose for blue matrix verified with data. The dose-response curve for blue component showed interval of linearity from 1 Gy to 20 Gy. (author)

  7. Competition of static magnetic and dynamic photon forces in electronic transport through a quantum dot.

    Science.gov (United States)

    Rauf Abdullah, Nzar; Tang, Chi-Shung; Manolescu, Andrei; Gudmundsson, Vidar

    2016-09-21

    We investigate theoretically the balance of the static magnetic and the dynamical photon forces in the electron transport through a quantum dot in a photon cavity with a single photon mode. The quantum dot system is connected to external leads and the total system is exposed to a static perpendicular magnetic field. We explore the transport characteristics through the system by tuning the ratio, [Formula: see text], between the photon energy, [Formula: see text], and the cyclotron energy, [Formula: see text]. Enhancement in the electron transport with increasing electron-photon coupling is observed when [Formula: see text]. In this case the photon field dominates and stretches the electron charge distribution in the quantum dot, extending it towards the contact area for the leads. Suppression in the electron transport is found when [Formula: see text], as the external magnetic field causes circular confinement of the charge density around the dot.

  8. Ultrafast terahertz electrodynamics of photonic and electronic nanostructures

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Liang [Iowa State Univ., Ames, IA (United States)

    2015-01-01

    This thesis summarizes my work on using ultrafast laser pulses to study Terahertz (THz) electrodynamics of photonic and electronic nanostructures and microstructures. Ultrafast timeresolved (optical, NIR, MIR, THz) pump-probe spectroscopy setup has been successfully built, which enables me to perform a series of relevant experiments. Firstly, a novel high e ciency and compact THz wave emitter based on split-ring-resonators has been developed and characterized. The emitter can be pumped at any wavelength by tailoring the magnetic resonance and could generate gapless THz waves covering the entire THz band. Secondly, two kinds of new photonic structures for THz wave manipulation have been successfully designed and characterized. One is based on the 1D and 2D photo-imprinted di ractive elements. The other is based on the photoexcited double-split-ring-resonator metamaterials. Both structures are exible and can modulate THz waves with large tunability. Thirdly, the dark excitons in semiconducting singlewalled carbon nanotubes are studied by optical pump and THz probe spectroscopy, which provides the rst insights into the THz responses of nonequilibrium excitonic correlations and dynamics from the dark ground states in carbon nanotubes. Next, several on-going projects are brie y presented such as the study of ultrafast THz dynamics of Dirac fermions in topological insulator Bi2Se3 with Mid-infrared excitation. Finally, the thesis ends with a summary of the completed experiments and an outlook of the future plan.

  9. SU-D-213-06: Dosimetry of Modulated Electron Radiation Therapy Using Fricke Gel Dosimeter

    Energy Technology Data Exchange (ETDEWEB)

    Gawad, M Abdel; Elgohary, M; Hassaan, M; Emam, M [Al Azhar University, Cairo Egypt (Egypt); Desouky, O [National center for radiation research and technology-Egyptian atomic energy, Cairo (Egypt); Eldib, A [Al Azhar University, Cairo Egypt (Egypt); Fox Chase Cancer Center, Philadelphia, PA (United States); Ma, C [Fox Chase Cancer Center, Philadelphia, PA (United States)

    2015-06-15

    Purpose: Modulated electron radiation therapy (MERT) has been proposed as an effective modality for treatment of superficial targets. MERT utilizes multiple beams of different energies which are intensity modulated to deliver optimized dose distribution. Energy independent dosimeters are thus needed for quantitative evaluations of MERT dose distributions and measurements of absolute doses delivered to patients. Thus in the current work we study the feasibility of Fricke gel dosimeters in MERT dosimetry. Methods: Batches of radiation sensitive Fricke gel is fabricated and poured into polymethyl methacrylate cuvettes. The samples were irradiated in solid water phantom and a thick layer of bolus was used as a buildup. A spectrophotometer system was used for measuring the color changes (the absorbance) before and after irradiation and then we calculate net absorbance. We constructed calibration curves to relate the measured absorbance in terms of absorbed dose for all available electron energies. Dosimetric measurements were performed for mixed electron beam delivery and we also performed measurement for segmented field delivery with the dosimeter placed at the junction of two adjacent electron beams of different energies. Dose measured by our gel dosimetry is compared to that calculation from our precise treatment planning system. We also initiated a Monte Carlo study to evaluate the water equivalence of our dosimeters. MCBEAM and MCSIM codes were used for treatment head simulation and phantom dose calculation. PDDs and profiles were calculated for electron beams incident on a phantom designed with 1cm slab of Fricke gel. Results: The calibration curves showed no observed energy dependence with all studied electron beam energies. Good agreement was obtained between dose calculated and that obtained by gel dosimetry. Monte Carlo results illustrated the tissue equivalency of our Gel dosimeters. Conclusion: Fricke Gel dosimeters represent a good option for the dosimetric

  10. Electron and photon impact studies of CF3I

    International Nuclear Information System (INIS)

    Mason, N.J.; Eden, S.; Limao Vieire, P.; Kendall, P.; Pathak, S.; Dawes, A.; Tegeder, P.; Kitajima, M.; Okamoto, M.; Tanaka, H.; Samukawa, S.; Cho, H.; Hoffmann, S.

    2002-01-01

    The manufacture of ultra-large-scale-integrated circuits, requires a well collimated, specially uniform, high density plasma source operating under low pressure conditions. The main feed gases used are perfluorocarbons, however these are also strong greenhouse gases, therefore must be replaced by alternative compounds with low global warming potentials. CF 3 I is one possible replacement, due to its high photolysis rate, is expected to have a very short lifetime in the atmosphere. It is also predicted to be able to produced high yields of CF 3 radicals in any etching plasma, since its weak C - I bond should be possible to break by direct electron impact. Prior adapting existing industrial plasma reactors to use CF 3 I, it is necessary to run simulations of the reactant plasma, requiring a detailed database of the electron interactions with the feed gases, however such CF 3 I data does not exist. Thus an exhaustive series of experiments to measure elastic and inelastic scattering from CF 3 I including a study of its electronic state spectroscopy using photon absorption and electron scattering techniques were performed. Electron energy loss spectroscopy (EELS) and photo-absorption spectroscopy were employed. A comprehensive set of differential cross sections for the elastic scattering CF 3 I over the impact energy region from 1.5 to 60 eV for scattering angles between 20 and 130 were compiled. The photo-absorption spectrum is characterized by three regions, the first is a very weak continuum around centered about 4.7 eV; the second consists of four prominent band structures observed around 7.4, 8.1, 9.0 and 9.8 eV, respectively, containing vibrational structure from 7 to 10 eV; the third (above the ionization potentials) could only be studied by using EELS and additional broad peaks were observed. (nevyjel)

  11. PREFACE: XXVIth International Conference on Photonic, Electronic and Atomic Collisions

    Science.gov (United States)

    Orel, Ann; Starace, Anthony F.; Nikolić, Dragan; Berrah, Nora; Gorczyca, Thomas W.; Kamber, Emanuel Y.; Tanis, John A.

    2009-12-01

    The XXVIth International Conference on Photonic, Electronic and Atomic Collisions was held on the campus of Western Michigan University (WMU) in Kalamazoo during 22-28 July 2009. Kalamazoo, the home of a major state university amid pleasant surroundings, was a delightful place for the conference. The 473 scientific participants, 111 of whom were students, had many fruitful discussions and exchanges that contributed to the success of the conference. Participants from 43 countries made the conference truly international in scope. The 590 abstracts that were presented on the first four days formed the heart of the conference and provided ample opportunity for discussion. This change, allowing the conference to end with invited talks, was a departure from the format used at previous ICPEAC gatherings in which the conferences ended with a poster session. The abstracts were split almost equally between the three main conference areas, i.e., photonic, electronic, and atomic collisions, and the posters were distributed across the days of the conference so that approximately equal numbers of abstracts in the different areas were scheduled for each day. Of the total number of presented abstracts, 517 of these are included in this proceedings volume, the first time that abstracts have been published by ICPEAC. There were 5 plenary lectures covering the different areas of the conference: Paul Corkum (University of Ottawa) talked on attosecond physics with atoms and molecules, Serge Haroche (Collège de France) on non-destructive photon counting, Toshiyuki Azuma (Tokyo Metropolitan University) on resonant coherent excitation of highly-charged ions in crystals, Eva Lindroth (Stockholm University) on atomic structure effects, and Alfred Müller (Justus Liebig University) on resonance phenomena in electron- and photon-ion collisions. Two speakers gave very illuminating public lectures that drew many people from the local area, as well as conference participants: Patricia Dehmer

  12. Anisotropic Electron-Photon and Electron-Phonon Interactions in Black Phosphorus.

    Science.gov (United States)

    Ling, Xi; Huang, Shengxi; Hasdeo, Eddwi H; Liang, Liangbo; Parkin, William M; Tatsumi, Yuki; Nugraha, Ahmad R T; Puretzky, Alexander A; Das, Paul Masih; Sumpter, Bobby G; Geohegan, David B; Kong, Jing; Saito, Riichiro; Drndic, Marija; Meunier, Vincent; Dresselhaus, Mildred S

    2016-04-13

    Orthorhombic black phosphorus (BP) and other layered materials, such as gallium telluride (GaTe) and tin selenide (SnSe), stand out among two-dimensional (2D) materials owing to their anisotropic in-plane structure. This anisotropy adds a new dimension to the properties of 2D materials and stimulates the development of angle-resolved photonics and electronics. However, understanding the effect of anisotropy has remained unsatisfactory to date, as shown by a number of inconsistencies in the recent literature. We use angle-resolved absorption and Raman spectroscopies to investigate the role of anisotropy on the electron-photon and electron-phonon interactions in BP. We highlight, both experimentally and theoretically, a nontrivial dependence between anisotropy and flake thickness and photon and phonon energies. We show that once understood, the anisotropic optical absorption appears to be a reliable and simple way to identify the crystalline orientation of BP, which cannot be determined from Raman spectroscopy without the explicit consideration of excitation wavelength and flake thickness, as commonly used previously.

  13. Numerical experiments with photons, electron and positrons by Monte Carlo

    International Nuclear Information System (INIS)

    Ilic, R.

    1996-01-01

    First version of the program FOTELP has presented at ETAN Conference in 1988. From 1991 this program has included in the international distribution (RSIC.Tenn., USA CCC-581). During the previous years the models of the Monte Carlo transport of photons, electrons and positrons were been modified, and includes the new cross section for elements from Z = 1 to Z = 100 in energy range from 1 keV to 20 MeV. The actual version of the program has the new numerical methods for probability calculations, and new techniques for sampling random values from their inverse distributions. The geometric module 05R were been replaced by more efficient module RFG for tic and tins zones in 3D. The experiences with programs ETRAN and ITS were been included. Available libraries of cross sections enabled program FOTELP to become the tool for numerical experiments in dosimetry, radiotherapy, radiation damage in electronics, and calculations radiation detectors efficiency. In this paper the new results of the program modifications were been presented with consideration on the models of other authors, and results of numerical experiments that approve validity of the new models included in the program. (author)

  14. EDITORIAL: Moore and more progress in electronics and photonics Moore and more progress in electronics and photonics

    Science.gov (United States)

    Meyyappan, Meyya

    2009-10-01

    This year marks the 20th volume of Nanotechnology, the first journal dedicated to the emerging field of nanotechnology, pre-empting the US National Nanotechnology Initiative (NNI) by ten years. Throughout the evolution and revolution of nanomaterials and devices, Nanotechnology has been at the forefront. The journal's first article on nanoelectronics reported research on electronic transport through three- dimensionally confined semiconductor quantum dots by Professor Mark Reed, now Editor-in-Chief, and his colleagues at the time at Texas Instruments in Dallas (Reed M A, Randall J N and Luscombe J H 1990 Nanotechnology 1 63-6). In the first decade of the journal, papers on nanoelectronics were scarce and primarily reported research on resonant tunnelling devices, transport in quantum dots and other III-V devices. With the ability to produce single-walled carbon nanotubes (SWCNTs) and semiconducting nanowires on patterned substrates using CVD and similar techniques, nanoscale electronics and photonics flourished. A pioneering contribution by Collins et al (Collins P G, Bando H and Zettl A 1998 Nanotechnology 9 153-7) discussed conductivity measurements on SWCNTs using scanning tunnelling microscopy. In the same issue, Fritzsche et al (Fritzsche W, Böhm Unger E and Köhler J M 1998 Nanotechnology 9 177-3) discussed making electrical contacts to a single molecule, another early contribution in molecular electronics. There have been numerous interesting and trend-setting articles. My personal favourite is an article from Hewlett-Packard researchers Greg Snider, Phil Kuekes and Stan Williams (2004 Nanotechnology 15 881-91) discussing an approach to building a defect-tolerant computer out of defective configurable FETs and switches. The construction of defect-free materials, devices and components may well begin to pose an obstacle to nanotechnology, so this pioneering article exhibits extraordinary foresight in attempting to construct a useful machine from defective

  15. Encapsulation of Polymer Colloids in a Sol-Gel Matrix. Direct-Writing of Coassembling Organic-Inorganic Hybrid Photonic Crystals.

    Science.gov (United States)

    Mikosch, Annabel; Kuehne, Alexander J C

    2016-03-22

    The spontaneous self-assembly of polymer colloids into ordered arrangements provides a facile strategy for the creation of photonic crystals. However, these structures often suffer from defects and insufficient cohesion, which result in flaking and delamination from the substrate. A coassembly process has been developed for convective assembly, resulting in large-area encapsulated colloidal crystals. However, to generate patterns or discrete deposits in designated places, convective assembly is not suitable. Here we experimentally develop conditions for direct-writing of coassembling monodisperse dye-doped polystyrene particles with a sol-gel precursor to form solid encapsulated photonic crystals. In a simple procedure the colloids are formulated in a sol-gel precursor solution, drop-cast on a flat substrate, and dried. We here establish the optimal parameters to form reproducible highly ordered photonic crystals with good optical performance. The obtained photonic crystals interact with light in the visible spectrum with a narrow optical stop-gap.

  16. Optimal electron and combined electron and photon therapy in the phase space of complication-free cure.

    Science.gov (United States)

    Asell, M; Hyödynmaa, S; Söderström, S; Brahme, A

    1999-01-01

    The possibility of using intensity-modulated high-energy electrons beams alone or in combination with photon beams to treat tumours located at depths from 5 cm to 25 cm has been investigated. A radiobiologically based optimization algorithm using the probability of complication-free tumour control has been used to calculate the optimal dose distributions. Two different target volumes have been used; one advanced cervical cancer with locally involved lymph nodes and one astrocytoma in the upper brain hemisphere. Treatments with only electron beams and also combinations between electron and photon beams have been investigated. The dependence of the expected treatment outcome on the beam energy and directions was investigated, and to some extent on the number of beam portals. It is shown that the beam direction intervals resulting in a high expected treatment outcome increase with increasing electron energy and also with some electron-photon combinations. For an eccentrically placed, not too deeply situated tumour surrounded by sensitive normal tissue it is shown that the expected treatment outcome can be improved by using electron beams in combination with photon beams compared with using two photon beams, and using two electron beams results in almost as high an expected treatment outcome. The possibility of improving the dose conformity from electron beams by adding photon fields parallel or orthogonal to the electron beams is demonstrated.

  17. Accelerating field spectrometer for photons and electrons simultaneous measurement. Application to decay schemes study

    International Nuclear Information System (INIS)

    Busani, Jean.

    1982-09-01

    An original spectrometer was built to improve the measurement of the absolute emission intensities of radionuclides with converted low energy gamma transitions. In this spectrometer, the same Si(Li) detector simultaneously measures electrons and photons emitted by the studied radionuclide; an electrostatic field may be established between the source and the detector to modify the electrons energy. This field allows the electron and photon peaks to be separated, and the absorption and energy straggling by detector windows to be decreased. Special attention has been given to determine spectrometer efficiency calibration curves for electrons and photons. 147 Nd and 133 Ba were used to test the spectrometer improvement and the method used [fr

  18. Deep-inelastic Electron-Photon Scattering at High Q^2 : Neutral and Charged Current Reactions

    OpenAIRE

    Ridder, A. Gehrmann-De

    1999-01-01

    We present the results of a calculation of deep inelastic electron-photon scattering at a linear collider for very high virtuality of the intermediate gauge boson up to NLO in perturbative QCD. The real photon is produced unpolarized via the Compton back scattering of laser light of the incoming beam. For $Q^2$ values close to the masses squared of the Z and W gauge bosons, the deep inelastic electron-photon scattering process receives important contributions not only from virtual photon exch...

  19. EGS4, Electron Photon Shower Simulation by Monte-Carlo

    International Nuclear Information System (INIS)

    1998-01-01

    1 - Description of program or function: The EGS code system is one of a chain of three codes designed to solve the electromagnetic shower problem by Monte Carlo simulation. This chain makes possible simulation of almost any electron-photon transport problem conceivable. The structure of the system, with its global features, modular form, and structured programming, is readily adaptable to virtually any interfacing scheme that is desired on the part of the user. EGS4 is a package of subroutines plus block data with a flexible user interface. This allows for greater flexibility without requiring the user to be overly familiar with the internal details of the code. Combining this with the macro facility capabilities of the Mortran3 language, this reduces the likelihood that user edits will introduce bugs into the code. EGS4 uses material cross section and branching ratio data created and fit by the companion code, PEGS4. EGS4 allows for the implementation of importance sampling and other variance reduction techniques such as leading particle biasing, splitting, path length biasing, Russian roulette, etc. 2 - Method of solution: EGS employs the Monte Carlo method of solution. It allows all of the fundamental processes to be included and arbitrary geometries can be treated, also. Other minor processes, such as photoneutron production, can be added as a further generalization. Since showers develop randomly according to the quantum laws of probability, each shower is different. We again are led to the Monte Carlo method. 3 - Restrictions on the complexity of the problem: None noted

  20. Electron-positron-photon cascades in the strong laser field

    Science.gov (United States)

    Legkov, Maxim; Fedotov, Alexander

    2012-06-01

    At nearest future several ambitious projects (such as ELI and HiPER) may provide laser filed intensity up to 10^23--10^24 W/cm^2. In such strong fields quantum effects are essential. The most important among them is production of QED cascades. In this paper external field intensity is considered as ultra-relativistic but subcritical. Using a model of two colliding counter-propagating laser beams it was shown that the number of particles during the process is growing exponentially in time. This leads to vast formation of electron-positron-photon plasma. According to numerical simulations, this plasma quickly absorbs an essential part of the energy of the laser field thus leading to its depletion. Numerical simulation has been also performed for a case of high-energetic particle and laser beam collision. Probability rates of direct and recombination processes have been theoretically studied. Under some conditions, recombination may come into play and suppress cascade development. Using approximation of radiation in forward direction, system of kinetic equations, which describes plasma evaluation, was constructed. According to qualitative estimations based on kinetic equations, it was shown that recombination processes can be neglected for optical frequencies range of external field.

  1. On bolus for megavoltage photon and electron radiation therapy

    International Nuclear Information System (INIS)

    Vyas, Vedang; Palmer, Lisa; Mudge, Ray; Jiang, Runqing; Fleck, Andre; Schaly, Bryan; Osei, Ernest; Charland, Paule

    2013-01-01

    Frequently, in radiation therapy one must treat superficial lesions on cancer patients; these are at or adjacent to the skin. Megavoltage photon radiotherapy penetrates through the skin to irradiate deep-seated tumors, with skin-sparing property. Hence, to treat superficial lesions, one must use a layer of scattering material to feign as the skin surface. Although megavoltage electron beams are used for superficial treatments, one occasionally needs to enhance the dose near the surface. Such is the function of a “bolus,” a natural or synthetically developed material that acts as a layer of tissue to provide a more effective treatment to the superficial lesions. Other uses of boluses are to correct for varying surface contours and to add scattering material around the patient's surface. Materials used as bolus vary from simple water to metal and include various mixtures and compounds. Even with the modernization of the technology for external-beam therapy and the emergence of various commercial boluses, the preparation and utilization of a bolus in clinical radiotherapy remains an art. Considering the varying experiences and practices, this paper briefly summarizes available boluses that have been proposed and are employed in clinical radiotherapy. Although this review is not exhaustive, it provides some initial guidance and answers questions that may arise in clinical practice

  2. Development of a portable graphite calorimeter for photons and electrons

    International Nuclear Information System (INIS)

    McEwen, M.R.; Duane, S.

    1999-01-01

    The aim of this project is to develop a calorimeter for use in both electron and photon beams. The calorimeter should be more robust than the present NPL primary standard X-ray calorimeter and is designed to be sufficiently portable to enable measurements at clinical accelerators away from NPL. Although intended for therapy-level dosimetry, the new calorimeter can also be used for high-dose measurements at industrial facilities. The system consists of a front end (the calorimeter itself), means for thermal isolation and temperature control, and a measurement system based on thermistors in a DC Wheatstone bridge. The early part of the project focused on the development of a temperature control system sensitive enough to allow measurements of temperature rises of the order of 1 mK. The control system responds to the calorimeter, phantom and air temperatures and maintains the temperature of the calorimeter to within ± 0.2 mK over several hours. Initial operation at NPL in 6, 10 and 16 MV X-ray beams show that the system is capable of measurements of 1 Gy at 2 Gy/min with a random uncertainty of ± 0.5% (1 standard deviation). (author)

  3. Electron beam collimation with a photon MLC for standard electron treatments

    Science.gov (United States)

    Mueller, S.; Fix, M. K.; Henzen, D.; Frei, D.; Frauchiger, D.; Loessl, K.; Stampanoni, M. F. M.; Manser, P.

    2018-01-01

    Standard electron treatments are currently still performed using standard or molded patient-specific cut-outs placed in the electron applicator. Replacing cut-outs and electron applicators with a photon multileaf collimator (pMLC) for electron beam collimation would make standard electron treatments more efficient and would facilitate advanced treatment techniques like modulated electron radiotherapy (MERT) and mixed beam radiotherapy (MBRT). In this work, a multiple source Monte Carlo beam model for pMLC shaped electron beams commissioned at a source-to-surface distance (SSD) of 70 cm is extended for SSDs of up to 100 cm and validated for several Varian treatment units with field sizes typically used for standard electron treatments. Measurements and dose calculations agree generally within 3% of the maximal dose or 2 mm distance to agreement. To evaluate the dosimetric consequences of using pMLC collimated electron beams for standard electron treatments, pMLC-based and cut-out-based treatment plans are created for a left and a right breast boost, a sternum, a testis and a parotid gland case. The treatment plans consist of a single electron field, either alone (1E) or in combination with two 3D conformal tangential photon fields (1E2X). For each case, a pMLC plan with similar treatment plan quality in terms of dose homogeneity to the target and absolute mean dose values to the organs at risk (OARs) compared to a cut-out plan is found. The absolute mean dose to an OAR is slightly increased for pMLC-based compared to cut-out-based 1E plans if the OAR is located laterally close to the target with respect to beam direction, or if a 6 MeV electron beam is used at an extended SSD. In conclusion, treatment plans using cut-out collimation can be replaced by plans of similar treatment plan quality using pMLC collimation with accurately calculated dose distributions.

  4. Photon counting imaging and centroiding with an electron-bombarded CCD using single molecule localisation software

    International Nuclear Information System (INIS)

    Hirvonen, Liisa M.; Barber, Matthew J.; Suhling, Klaus

    2016-01-01

    Photon event centroiding in photon counting imaging and single-molecule localisation in super-resolution fluorescence microscopy share many traits. Although photon event centroiding has traditionally been performed with simple single-iteration algorithms, we recently reported that iterative fitting algorithms originally developed for single-molecule localisation fluorescence microscopy work very well when applied to centroiding photon events imaged with an MCP-intensified CMOS camera. Here, we have applied these algorithms for centroiding of photon events from an electron-bombarded CCD (EBCCD). We find that centroiding algorithms based on iterative fitting of the photon events yield excellent results and allow fitting of overlapping photon events, a feature not reported before and an important aspect to facilitate an increased count rate and shorter acquisition times.

  5. Photonics

    CERN Document Server

    Andrews, David L

    2015-01-01

    Discusses the basic physical principles underlying thescience and technology of nanophotonics, its materials andstructures This volume presents nanophotonic structures and Materials.Nanophotonics is photonic science and technology that utilizeslight/matter interactions on the nanoscale where researchers arediscovering new phenomena and developing techniques that go wellbeyond what is possible with conventional photonics andelectronics.The topics discussed in this volume are: CavityPhotonics; Cold Atoms and Bose-Einstein Condensates; Displays;E-paper; Graphene; Integrated Photonics; Liquid Cry

  6. Photonics

    CERN Document Server

    Andrews, David L

    2015-01-01

    Discusses the basic physical principles underlying Biomedical Photonics, spectroscopy and microscopy This volume discusses biomedical photonics, spectroscopy and microscopy, the basic physical principles underlying the technology and its applications. The topics discussed in this volume are: Biophotonics; Fluorescence and Phosphorescence; Medical Photonics; Microscopy; Nonlinear Optics; Ophthalmic Technology; Optical Tomography; Optofluidics; Photodynamic Therapy; Image Processing; Imaging Systems; Sensors; Single Molecule Detection; Futurology in Photonics. Comprehensive and accessible cov

  7. Photonics

    CERN Document Server

    Andrews, David L

    2015-01-01

    This book covers modern photonics accessibly and discusses the basic physical principles underlying all the applications and technology of photonicsThis volume covers the basic physical principles underlying the technology and all applications of photonics from statistical optics to quantum optics. The topics discussed in this volume are: Photons in perspective; Coherence and Statistical Optics; Complex Light and Singular Optics; Electrodynamics of Dielectric Media; Fast and slow Light; Holography; Multiphoton Processes; Optical Angular Momentum; Optical Forces, Trapping and Manipulation; Pol

  8. Photonics

    CERN Document Server

    Andrews, David L

    2015-01-01

    Discusses the basic physical principles underlying the technology instrumentation of photonics This volume discusses photonics technology and instrumentation. The topics discussed in this volume are: Communication Networks; Data Buffers; Defense and Security Applications; Detectors; Fiber Optics and Amplifiers; Green Photonics; Instrumentation and Metrology; Interferometers; Light-Harvesting Materials; Logic Devices; Optical Communications; Remote Sensing; Solar Energy; Solid-State Lighting; Wavelength Conversion Comprehensive and accessible coverage of the whole of modern photonics Emphas

  9. Dose rate and energy dependence study of methacrylic acid gelatin tetrakis (hydroxymethyl) phosphonium chloride gel with flattened and unflattened photon beams.

    Science.gov (United States)

    Sathiyaraj, P; Samuel, James Jebaseelan

    2018-01-01

    The aim of this study is to evaluate the dose rate and energy dependency of methacrylic acid gelatin tetrakis (hydroxymethyl) phosphonium chloride (MAGAT) gel in unflattened photon beam using X-ray computed tomography (CT) and ultraviolet (UV)-visible spectroscopy. MAGAT gel was prepared and it was exposed to 6 MV flattened and unflattened beams. The dose selected for irradiation was ranging from 3 to 15 Gy with an increment of 3 Gy. The dose rate dependency of the gel was investigated by exposing the gel to three different dose rates of 250, 500, and 1500 cGy/min for flattening filter free (FFF). To verify the energy dependency of the gel, it was exposed by both FFF and flattening filter (FF) for constant dose rate (250 cGy/min) and different energy (6 and 10 MV X-ray photons). The exposed gels were scanned by X-ray CT and UV-visible spectrophotometer. The change in dose sensitivity observed over the dose rate from 250 cGy/min to 1500 cGy/min was 58.00% and 57.89% using a UV-visible spectrophotometer and X-ray CT analysis method. Energy dependency was evaluated with respect to dose sensitivity and the variation between 6 MV FF and FFF photon beams was found to be 2.20% and 2.21% using UV-visible spectrophotometer analysis and X-ray CT, respectively. Similarly, the variation noticed with 10 MV FF and FFF was 2.30% using UV-visible spectrophotometer analysis and 2.22% using X-ray CT analysis. The results clearly show that the MAGAT gel was highly dose rate-dependent and less dependent on energy. The beam quality variation between FF and FFF was less. The similar results obtained using X-ray CT scanner and UV-visible spectrophotometer indicate that this study can be recommended for polymer gel scanning procedure.

  10. Calibration of electrons and photons with the ATLAS detector, and its impact on ATLAS precision measurements

    CERN Document Server

    Becot, C; The ATLAS collaboration

    2014-01-01

    A precise energy calibration of electrons and photons is a key ingredient to many measurements performed with the ATLAS detector, such as the measurement of the Higgs boson mass. An improved calibration scheme is based on corrections derived from collision data, multivariant algorithms for the energy reconstruction and finally electrons from Z boson decays to set the absolute energy scale. Studies of the longitudinal shape of electromagnetic showers also lead to an improved detector material simulation. The calibration is checked with electrons from J/psi decays and photons from radiative photon decays. This contribution will describe the calibration scheme and the cross checks and the impact on ATLAS measurements.

  11. Unfolding of hemoglobin variants--insights from urea gradient gel electrophoresis photon correlation spectroscopy and zeta potential measurements

    International Nuclear Information System (INIS)

    Bhattacharya, Jaydeep; GhoshMoulick, Ranjita; Choudhuri, Utpal; Chakrabarty, Prantar; Bhattacharya, Pranab K.; Lahiri, Prabir; Chakraborti, Bikas; Dasgupta, Anjan Kr.

    2004-01-01

    The unfolding pattern of crystal human hemoglobin and variants of hemoglobin obtained from hemolysate were studied using transverse urea gradient gel electrophoresis (TUGGE). A smooth sigmoid like increase of electrophoretic mobility was observed with increasing urea concentrations. A decrease in electrophoretic mobility resulted, if the protein was unfolded with guanidium hydrochloride (GdnHCl). The anomaly was resolved after the Stoke's radii (obtained using the photon correlation spectroscopy) and zeta potential (measured using laser Doppler velocimetry) measurements were made at different denaturant concentrations. Addition of denaturant led to formation of extended structure, irrespective of the nature of the denaturant, as indicated by increase in Stoke's radii in both cases (urea and GdnHCl). The unexpected increase in electrophoretic mobility in case of urea could be explained in terms of a critical redistribution of negative charge at intermediate stages of the unfolding process. In case of GdnHCl, the higher ionic strength masked the charge effect. The mobility, being solely dependent on size, decreased at higher denaturant concentration. Incidentally, folding loci of other hemoglobin variants (e.g. HbE) or that of post-translationally modified hemoglobin (e.g. HbA1c) could be determined by studying the charge distribution and hydrodynamic radius at varying denaturing stress and in each case the gel migration profile could be approximately scaled by the ratio of charge and hydrodynamic diameter of the protein. While unfolding induced charge effect was most pronounced in HbA0 (and crystal ferrous hemoglobin), the unfolding induced aggregation (manifested by the increase in Stoke's radii) was predominantly observed in the variant forms HbE and HbA1c. Representing the proteins by a plot, in which charge and hydrodynamic diameter are on independent axes, may be a useful way of characterizing protein variants having similar migration profiles on native gels

  12. ZZ ENDLIB, Coupled Electron and Photon Transport Library in ENDL Format

    International Nuclear Information System (INIS)

    2002-01-01

    Description of program or function: The LLNL Evaluated Nuclear Data Library has existed since 1958 in a succession of forms and formats. The present form is as a machine-independent character file format and contains data for the evaluated atomic relaxation data library (EADL), the evaluated photon interaction data library (EPDL), and the evaluated electron interaction data library (EEDL). The purpose of these libraries is to furnish data for coupled electron-photon transport calculations. In order to perform coupled photon-electron transport calculations, all three libraries are required. The UCRL-ID-117796 report included in the documentation for this package provides information on the contents and formats for all three libraries, which are included in this package. All of these libraries span atomic numbers, Z, from 1 to 100. Additionally the electron and photon interaction libraries cover the incident particle energy range from 10 eV to 100 GeV

  13. Design of Pixellated CMOS Photon Detector for Secondary Electron Detection in the Scanning Electron Microscope

    Directory of Open Access Journals (Sweden)

    Joon Huang Chuah

    2011-01-01

    Full Text Available This paper presents a novel method of detecting secondary electrons generated in the scanning electron microscope (SEM. The method suggests that the photomultiplier tube (PMT, traditionally used in the Everhart-Thornley (ET detector, is to be replaced with a configurable multipixel solid-state photon detector offering the advantages of smaller dimension, lower supply voltage and power requirements, and potentially cheaper product cost. The design of the proposed detector has been implemented using a standard 0.35 μm CMOS technology with optical enhancement. This microchip comprises main circuit constituents of an array of photodiodes connecting to respective noise-optimised transimpedance amplifiers (TIAs, a selector-combiner (SC circuit, and a postamplifier (PA. The design possesses the capability of detecting photons with low input optical power in the range of 1 nW with 100 μm × 100 μm sized photodiodes and achieves a total amplification of 180 dBΩ at the output.

  14. Matching beams on photon/electron linear accelerators

    International Nuclear Information System (INIS)

    Oliver, L.; Vial, P.; Hunt, P.

    2004-01-01

    Full text: There are a number of obvious reasons to match megavoltage X-ray and electron beams for clinical purposes. If two dual-purpose X-ray/electron linear accelerators are of the same design and manufacturer, then this might be possible. The issue is however whether the beams can be matched sufficiently close to be considered the same for patient treatments and planning data for dose calculation purposes. If successfully achieved, there are significant advantages in reduced commissioning time, less work in planning and flexibility in the treatment of patients between the two treatment machines. We have investigated matching a new Varian Clinac 21EX with our 1993 Varian Clinac 2100 C/D. A Varian Clinac 1800 was the first linear accelerator installed at RNSH in 1987. When the Clinac 2100 C/D was installed in 1993, we attempted to match all the X-ray and electron beams with the original Clinac 1800 physical data. The X-ray beam characteristics were satisfactory but the electron beams were not sufficiently compatible for planning or patient treatment purposes. A different designed scattering foil and electron applicator were the cause of the different electron beam physical characteristics between the two models. In replacing the Clinac 1800 with the Clinac 21EX, we have used the original 1993 data of the Clinac 2100 C/D as the gold standard to aim for. Initial measurements during acceptance tests showed that all beams satisfied the manufacturer's specification. The energy was then matched to the existing clinical physics data by adjusting the bending magnet power supply and re-tuning the accelerator. This involved matching % depth dose and the corresponding ratio of 10 and 20 cm % depth dose ratio for 6MV and 18 MV X-ray beams. For 6, 9, 12, 16 and 20 MeV electron beams the normal physical parameters of depth of maximum (R max ), the practical range (R p ), the depth of 50% (R 50 ), the slope (G), the average energy at the surface (E 0 ) and the % photon

  15. Cavity-photon contribution to the effective interaction of electrons in parallel quantum dots

    Energy Technology Data Exchange (ETDEWEB)

    Gudmundsson, Vidar [Science Institute, University of Iceland, Reykjavik (Iceland); Sitek, Anna [Science Institute, University of Iceland, Reykjavik (Iceland); Department of Theoretical Physics, Faculty of Fundamental Problems of Technology, Wroclaw University of Technology (Poland); Abdullah, Nzar Rauf [Science Institute, University of Iceland, Reykjavik (Iceland); Physics Department, Faculty of Science and Science Education, School of Science, University of Sulaimani, Kurdistan Region (Iraq); Tang, Chi-Shung [Department of Mechanical Engineering, National United University, Miaoli (China); Manolescu, Andrei [School of Science and Engineering, Reykjavik University (Iceland)

    2016-05-15

    A single cavity photon mode is expected to modify the Coulomb interaction of an electron system in the cavity. Here we investigate this phenomena in a parallel double quantum dot system. We explore properties of the closed system and the system after it has been opened up for electron transport. We show how results for both cases support the idea that the effective electron-electron interaction becomes more repulsive in the presence of a cavity photon field. This can be understood in terms of the cavity photons dressing the polarization terms in the effective mutual electron interaction leading to nontrivial delocalization or polarization of the charge in the double parallel dot potential. In addition, we find that the effective repulsion of the electrons can be reduced by quadrupolar collective oscillations excited by an external classical dipole electric field. (copyright 2015 by WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  16. Measurement of the BESSY II electron beam energy by Compton-backscattering of laser photons

    CERN Document Server

    Klein, R; Thornagel, R; Brandt, G; Görgen, R; Ulm, G

    2002-01-01

    Accurate knowledge of all storage ring parameters is essential for the Physikalisch-Technische Bundesanstalt (PTB) to operate the electron storage ring BESSY II as a primary source standard. One parameter entering the Schwinger equation for the calculation of the spectral photon flux of bending magnet radiation is the electron beam energy. So at BESSY II the electron beam energy is measured by two independent techniques one of which is described in this paper: the photons from a CO sub 2 -laser are scattered in a head-on collision with the stored electrons. From the spectrum of the backscattered photons that are detected by an energy-calibrated HPGe detector the electron beam energy can be determined. The experimental set-up at the BESSY II electron storage ring as well as the current experimental status are described for operation of the storage ring at the energies of 900 and 1700 MeV.

  17. Electron and photon reconstruction and performance in ATLAS using a dynamical, topological cell clustering-based approach

    CERN Document Server

    The ATLAS collaboration

    2017-01-01

    The electron and photon reconstruction in ATLAS has moved towards the use of a dynamical, topo- logical cell-based approach for cluster building, owing to advancements in the calibration procedure which allow for such a method to be applied. The move to this new technique allows for improved measurements of electron and photon energies, particularly in situations where an electron radiates a bremsstrahlung photon, or a photon converts to an electron-poistron pair. This note details the changes to the ATLAS electron and photon reconstruction software, and assesses its performance under current LHC luminosity conditions using simulated data. Changes to the converted photon reconstruction are also detailed, which improve the reconstruction efficiency of double-track converted photons, as well as reducing the reconstruction of spurious one-track converted photons. The performance of the new reconstruction algorithm is also presented in a number of important topologies relevant to precision Standard Model physics,...

  18. Electromagnetic cascade in high-energy electron, positron, and photon interactions with intense laser pulses

    Science.gov (United States)

    Bulanov, S. S.; Schroeder, C. B.; Esarey, E.; Leemans, W. P.

    2013-06-01

    The interaction of high-energy electrons, positrons, and photons with intense laser pulses is studied in head-on collision geometry. It is shown that electrons and/or positrons undergo a cascade-type process involving multiple emissions of photons. These photons can consequently convert into electron-positron pairs. As a result charged particles quickly lose their energy developing an exponentially decaying energy distribution, which suppresses the emission of high-energy photons, thus reducing the number of electron-positron pairs being generated. Therefore, this type of interaction suppresses the development of the electromagnetic avalanche-type discharge, i.e., the exponential growth of the number of electrons, positrons, and photons does not occur in the course of interaction. The suppression will occur when three-dimensional effects can be neglected in the transverse particle orbits, i.e., for sufficiently broad laser pulses with intensities that are not too extreme. The final distributions of electrons, positrons, and photons are calculated for the case of a high-energy e-beam interacting with a counterstreaming, short intense laser pulse. The energy loss of the e-beam, which requires a self-consistent quantum description, plays an important role in this process, as well as provides a clear experimental observable for the transition from the classical to quantum regime of interaction.

  19. Relativistic quantum dynamics in strong fields: Photon emission from heavy, few-electron ions

    International Nuclear Information System (INIS)

    Fritzsche, S.; Stoehlker, T.

    2005-03-01

    Recent progress in the study of the photon emission from highly-charged heavy ions is reviewed. These investigations show that high-Z ions provide a unique tool for improving the understanding of the electron-electron and electron-photon interaction in the presence of strong fields. Apart from the bound-state transitions, which are accurately described in the framework of quantum electrodynamics, much information has been obtained also from the radiative capture of (quasi-) free electrons by high-Z ions. Many features in the observed spectra hereby confirm the inherently relativistic behavior of even the simplest compound quantum systems in nature. (orig.)

  20. Electron beam irradiation after reconstruction with silicone gel implant in breast cancer

    International Nuclear Information System (INIS)

    Krishnan, L.; Krishnan, E.C.

    1986-01-01

    Irradiation for breast cancer in the presence of a silicone gel breast prosthesis is sometimes necessary. There is a concern among radiation and other oncologists as to whether the presence of the prosthetic implant would interfere with delivery of the needed irradiation doses. Electron beams, with their finite penetration and rapid fall-off, offer a mode of adequately treating the recurrence and minimizing the radiation to the underlying normal structures, such as the lung and the heart. The dose distribution using 9-20 MeV electrons in the presence of a breast prosthesis is compared to the dose distribution without the implant in a tissue equivalent water phantom. The results reveal no significant difference in the dose delivered due to the presence of the prosthesis. Clinical verification of the dosimetry in the presence of the prosthesis confirmed that the presence of the silicone gel implant does not compromise treatment by irradiation in the management of breast cancer

  1. Trapping photon-dressed Dirac electrons in a quantum dot studied by coherent two dimensional photon echo spectroscopy

    Science.gov (United States)

    Roslyak, O.; Gumbs, Godfrey; Mukamel, S.

    2012-05-01

    We study the localization of dressed Dirac electrons in a cylindrical quantum dot (QD) formed on monolayer and bilayer graphene by spatially different potential profiles. Short lived excitonic states which are too broad to be resolved in linear spectroscopy are revealed by cross peaks in the photon-echo nonlinear technique. Signatures of the dynamic gap in the two-dimensional spectra are discussed. The effect of the Coulomb induced exciton-exciton scattering and the formation of biexciton molecules are demonstrated.

  2. Constraints on photon pulse duration from longitudinal electron beam diagnostics at a soft x-ray free-electron laser

    Directory of Open Access Journals (Sweden)

    C. Behrens

    2012-03-01

    Full Text Available The successful operation of x-ray free-electron lasers (FELs, like the Linac Coherent Light Source or the Free-Electron Laser in Hamburg (FLASH, makes unprecedented research on matter at atomic length and ultrafast time scales possible. However, in order to take advantage of these unique light sources and to meet the strict requirements of many experiments in photon science, FEL photon pulse durations need to be known and tunable. This can be achieved by controlling the FEL driving electron beams, and high-resolution longitudinal electron beam diagnostics can be utilized to provide constraints on the expected FEL photon pulse durations. In this paper, we present comparative measurements of soft x-ray pulse durations and electron bunch lengths at FLASH. The soft x-ray pulse durations were measured by FEL radiation pulse energy statistics and compared to electron bunch lengths determined by frequency-domain spectroscopy of coherent transition radiation in the terahertz range and time-domain longitudinal phase space measurements. The experimental results, theoretical considerations, and simulations show that high-resolution longitudinal electron beam diagnostics provide reasonable constraints on the expected FEL photon pulse durations. In addition, we demonstrated the generation of soft x-ray pulses with durations below 50 fs (FWHM after the implementation of the new uniform electron bunch compression scheme used at FLASH.

  3. Cavity Born-Oppenheimer Approximation for Correlated Electron-Nuclear-Photon Systems.

    Science.gov (United States)

    Flick, Johannes; Appel, Heiko; Ruggenthaler, Michael; Rubio, Angel

    2017-04-11

    In this work, we illustrate the recently introduced concept of the cavity Born-Oppenheimer approximation [ Flick et al. PNAS 2017 , 10.1073/pnas.1615509114 ] for correlated electron-nuclear-photon problems in detail. We demonstrate how an expansion in terms of conditional electronic and photon-nuclear wave functions accurately describes eigenstates of strongly correlated light-matter systems. For a GaAs quantum ring model in resonance with a photon mode we highlight how the ground-state electronic potential-energy surface changes the usual harmonic potential of the free photon mode to a dressed mode with a double-well structure. This change is accompanied by a splitting of the electronic ground-state density. For a model where the photon mode is in resonance with a vibrational transition, we observe in the excited-state electronic potential-energy surface a splitting from a single minimum to a double minimum. Furthermore, for a time-dependent setup, we show how the dynamics in correlated light-matter systems can be understood in terms of population transfer between potential energy surfaces. This work at the interface of quantum chemistry and quantum optics paves the way for the full ab initio description of matter-photon systems.

  4. The relevance of the vertex bremsstrahlung photon detection in the electron-neutrino (antineutrino) electron scattering experiments at low energy

    CERN Document Server

    Broggini, C; Moretti, M

    1999-01-01

    We discuss the size of the electron-antineutrino electron into electron-antineutrino electron cross section reduction due to the rejection of the events with a vertex bremsstrahlung photon above a certain energy in the final state. In particular we analyze the effect in experiments designed to detect the low energy electron-antineutrino and electron-neutrino from a nuclear reactor and from the Sun. We find that such reduction has to be considered in a relatively high statistic reactor experiment, while it is negligible for pp and 7Be solar neutrino detection.

  5. Modelling of electron contamination in clinical photon beams for Monte Carlo dose calculation

    International Nuclear Information System (INIS)

    Yang, J; Li, J S; Qin, L; Xiong, W; Ma, C-M

    2004-01-01

    The purpose of this work is to model electron contamination in clinical photon beams and to commission the source model using measured data for Monte Carlo treatment planning. In this work, a planar source is used to represent the contaminant electrons at a plane above the upper jaws. The source size depends on the dimensions of the field size at the isocentre. The energy spectra of the contaminant electrons are predetermined using Monte Carlo simulations for photon beams from different clinical accelerators. A 'random creep' method is employed to derive the weight of the electron contamination source by matching Monte Carlo calculated monoenergetic photon and electron percent depth-dose (PDD) curves with measured PDD curves. We have integrated this electron contamination source into a previously developed multiple source model and validated the model for photon beams from Siemens PRIMUS accelerators. The EGS4 based Monte Carlo user code BEAM and MCSIM were used for linac head simulation and dose calculation. The Monte Carlo calculated dose distributions were compared with measured data. Our results showed good agreement (less than 2% or 2 mm) for 6, 10 and 18 MV photon beams

  6. A Comparison of Clinical and Dosimetric Outcomes in Patients Receiving Partial Breast Irradiation with Photon-Only versus Mixed Photon/Electron Treatment Plans

    International Nuclear Information System (INIS)

    Shah, Mira M.; Horton, Janet K.; Yoo, Sua; Hubbs, Jessica L.; Demirci, Senem; Light, Kim L.; Temple, Kathy; Patrone, Michael; Marks, Lawrence B.

    2011-01-01

    Several series evaluating external-beam partial breast irradiation (PBI) have linked negative cosmetic outcomes to large normal tissue treatment volumes. We compared patients treated with PBI whose treatment plans included only photons to those whose plans incorporated electrons. Twenty-seven patients were identified: median age 67 years, pT1 82%, pN0 56%, margin negative 100%. All received 38.5 Gy using 3–5 noncoplanar photon beams (6-15X). Electrons (9–20 MeV) were included in 59%. Median follow-up was 22 months. Ninety percent experienced good/excellent cosmetic outcomes. Two patients had fair cosmesis, and both were treated with a mixed photon/electron approach. Median conformity index for photon-only treatment plans was 1.7 (range, 0.9–2.0) and for photon/electron plans, 1.0 (0.3–1.4). Median percent ipsilateral breast volume receiving 100% and 50% of prescription dose was 19 and 50 for photon-only plans vs. 10 and 38 for photon/electron plans (p < 0.05). Median percent target volume receiving 100% and 95% of prescription dose was 93 and 98 for photon-only plans vs. 75 and 94 for photon/electron plans (p < 0.05). A mixed photon/electron, noncoplanar technique decreases the volume of treated normal breast tissue at the cost of slightly decreased tumor bed coverage. Further study is needed to determine whether this results in a more favorable therapeutic ratio than photon-only approaches.

  7. In situ electrical and thermal monitoring of printed electronics by two-photon mapping

    DEFF Research Database (Denmark)

    Pastorelli, Francesco; Accanto, Nicolo; Jørgensen, Mikkel

    2017-01-01

    Printed electronics is emerging as a new, large scale and cost effective technology that will be disruptive in fields such as energy harvesting, consumer electronics and medical sensors. The performance of printed electronic devices relies principally on the carrier mobility and molecular packing......-destructive and low-cost testing method is needed. In this study, we demonstrate that nonlinear optical microscopy is a promising technique to achieve this goal. Using ultrashort laser pulses we stimulate two-photon absorption in a roll coated polymer semiconductor and map the resulting two-photon induced...

  8. Monolithic nanoscale photonics-electronics integration in silicon and other group IV elements

    CERN Document Server

    Radamson, Henry

    2014-01-01

    Silicon technology is evolving rapidly, particularly in board-to-board or chip-to chip applications. Increasingly, the electronic parts of silicon technology will carry out the data processing, while the photonic parts take care of the data communication. For the first time, this book describes the merging of photonics and electronics in silicon and other group IV elements. It presents the challenges, the limitations, and the upcoming possibilities of these developments. The book describes the evolution of CMOS integrated electronics, status and development, and the fundamentals of silicon p

  9. Double electron ionization in Compton scattering of high energy photons by helium atoms

    International Nuclear Information System (INIS)

    Amusia, M.Y.; Mikhailov, A.I.

    1995-01-01

    The cross section for double-electron ionization of two-electron atoms and ions in Compton scattering of high energy photons is calculated. It is demonstrated that its dependence on the incoming photon frequency is the same as that for single-electron ionization. The ratio of open-quotes double-to-singleclose quotes ionization in Compton scattering was found to be energy independent and almost identical with the corresponding value for photoionization. For the He atom it is 1.68%. This surprising result deserves experimental verification

  10. Double electron ionization in Compton scattering of high energy photons by helium atoms

    Energy Technology Data Exchange (ETDEWEB)

    Amusia, M.Y.; Mikhailov, A.I. [St. Petersburg Nuclear Physics Institute, Gatchina (Russian Federation)

    1995-08-01

    The cross section for double-electron ionization of two-electron atoms and ions in Compton scattering of high energy photons is calculated. It is demonstrated that its dependence on the incoming photon frequency is the same as that for single-electron ionization. The ratio of {open_quotes}double-to-single{close_quotes} ionization in Compton scattering was found to be energy independent and almost identical with the corresponding value for photoionization. For the He atom it is 1.68%. This surprising result deserves experimental verification.

  11. Effects of model approximations for electron, hole, and photon transport in swift heavy ion tracks

    Czech Academy of Sciences Publication Activity Database

    Rymzhanov, R.A.; Medvedev, Nikita; Volkov, A.E.

    2016-01-01

    Roč. 388, Dec (2016), s. 41-52 ISSN 0168-583X R&D Projects: GA MŠk LG15013 Institutional support: RVO:68378271 Keywords : swift heavy ion * electronic stopping * TREKIS * Monte Carlo * electronic kinetics * photon transport Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.109, year: 2016

  12. Characteristics of electrons emitted from aluminium, carbon and mylar slabs irradiated by photons

    Energy Technology Data Exchange (ETDEWEB)

    Malbert, M.; Terrissol, M.; Patau, J.P. (Toulouse-3 Univ., 31 (France). Centre de Physique Atomique); Angles, M. (CEG, 46 - Gramat (France))

    1982-01-01

    The forward and backscattered electron fluence emitted by a slab under photon irradiation have been calculated using Monte-Carlo techniques for aluminium, carbon and mylar. The simulation methods used and the techniques chosen to study the low energy (< 30 keV) electron transport are presented. The agreement with experimental and other theoretical results is good.

  13. The Two-Photon Exchange Contribution to Elastic Electron-Nucleon Scattering at Large Momentum Transfer

    Energy Technology Data Exchange (ETDEWEB)

    Afanasev, A.

    2005-02-02

    We estimate the two-photon exchange contribution to elastic electron-proton scattering at large momentum transfer by using a quark-parton representation of virtual Compton scattering. We thus can relate the two-photon exchange amplitude to the generalized parton distributions which also enter in other wide angle scattering processes. We find that the interference of one- and two-photon exchange contribution is able to substantially resolve the difference between electric form factor measurements from Rosenbluth and polarization transfer experiments. Two-photon exchange has additional consequences which could be experimentally observed, including nonzero polarization effects and a positron-proton/electron-proton scattering asymmetry. The predicted Rosenbluth plot is no longer precisely linear; it acquires a measurable curvature, particularly at large laboratory angle.

  14. The ARGUS electron/photon calorimeter. Pt. 2

    International Nuclear Information System (INIS)

    Drescher, A.; Graf, H.J.; Graewe, B.; Hofmann, W.; Markees, A.; Matthiesen, U.; Spengler, J.; Wegener, D.

    1983-03-01

    A detailed investigation is described of the photon production and transport in lead scintillator shower counters with wave-length shifter readout built for the ARGUS detector. Experimental data and Monte Carlo calculations are in good agreement. The most prominent effects due to the light collection system are small nonlinearities in the relation between deposited energy and pulse height and an energy dependent decrease of the energy resolution of the counters. (orig.)

  15. The two-photon exchange contribution to elastic electron-nucleon scattering at large momentum transfer

    Energy Technology Data Exchange (ETDEWEB)

    Andrei V. Afanasev; Stanley J. Brodsky; Carl E. Carlson; Yu-Chun Chen; Marc Vanderhaeghen

    2005-01-01

    We estimate the two-photon exchange contribution to elastic electron-proton scattering at large momentum transfer by using a quark-parton representation of virtual Compton scattering. We thus can relate the two-photon exchange amplitude to the generalized parton distributions which also enter in other wide angle scattering processes. We find that the interference of one- and two-photon exchange contribution is able to substantially resolve the difference between electric form factor measurements from Rosenbluth and polarization transfer experiments.

  16. Two-temperature accretion disks with electron-positron pairs - Effects of Comptonized external soft photons

    Science.gov (United States)

    Kusunose, Masaaki; Takahara, Fumio

    1990-01-01

    The present account of the effects of soft photons from external sources on two-temperature accretion disks in electron-positron pair equilibrium solves the energy-balance equation for a given radial distribution of the input rate of soft photons, taking into account their bremsstrahlung and Comptonization. Critical rate behavior is investigated as a function of the ratio of the energy flux of incident soft photons and the energy-generation rate. As in a previous study, the existence of a critical accretion rate is established.

  17. Two-photon free-free transitions in laser-assisted electron-hydrogen scattering

    International Nuclear Information System (INIS)

    Kracke, G.; Briggs, J.S.; Dubois, A.; Maquet, A.; Veniard, V.

    1994-01-01

    We present a perturbative calculation of the cross section for two-photon free-free transitions in laser assisted electron-hydrogen scattering within the first Born approximation. The virtual one- and two-photon excitations of the hydrogen atom during the scattering event are taken into account explicitly and their importance is demonstrated for the special case of the hydrogen atom remaining in its ground state after the collision. (Author)

  18. Nonlinear spectroscopy of photon-dressed Dirac electrons in a quantum dot

    Science.gov (United States)

    Roslyak, O.; Gumbs, Godfrey; Mukamel, S.

    2013-01-01

    We study the localization of dressed Dirac electrons in a cylindrical quantum dot (QD) formed on monolayer and bilayer graphene by spatially different potential profiles. Short-lived excitonic states which are too broad to be resolved in linear spectroscopy are revealed by cross-peaks in the photon-echo nonlinear technique. Signatures of the dynamic gap in the two-dimensional photon-echo spectra are discussed.

  19. One-photon annihilation of thermal positrons with bound atomic electrons

    Science.gov (United States)

    Jung, Young-Dae

    1994-01-01

    Direct one-photon annihilation rate of positrons with a bound atomic electron is evaluated in the nonrelativistic limit. The K- and L-shell contributions are estimated including the screening and effective Coulomb repulsion effects. The annihilation rate of thermal positrons is calculated for various temperatures. The total number of one-photon annihilation events in the interstellar medium is discussed. These results provide the directional and structural information for cosmic gamma-ray sources.

  20. A New Approach of Electronics and Photonics Convergence on Si CMOS Platform: How to Reduce Device Diversity of Photonics for Integration

    Directory of Open Access Journals (Sweden)

    Kazumi Wada

    2008-01-01

    Full Text Available Integrated photonics via Si CMOS technology has been a strategic area since electronics and photonics convergence should be the next platform for information technology. The platform is recently referred to as “Si photonics” that attracts much interest of researchers in industries as well as academia in the world. The main goal of Si Photonics is currently to reduce material diversity of photonic devices to pursuing CMOS-compatibility. In contrast, the present paper proposes another route of Si Photonics, reducing diversity of photonic devices. The proposed device unifying functionality of photonics is a microresonator with a pin diode structure that enables the Purcell effect and Franz-Keldysh effect to emit and to modulate light from SiGe alloys.

  1. Electron beam crosslinked gels-Preparation, characterization and their effect on the mechanical, dynamic mechanical and rheological properties of rubbers

    International Nuclear Information System (INIS)

    Mitra, Suman; Chattopadhyay, Santanu; Sabharwal, Sunil; Bhowmick, Anil K.

    2010-01-01

    Electron beam (EB) crosslinked natural rubber (NR) gels were prepared by curing NR latex with EB irradiation over a range of doses from 2.5 to 20 kGy using butyl acrylate as sensitizer. The NR gels were systematically characterized by solvent swelling, dynamic light scattering, mechanical and dynamic mechanical properties. These gels were introduced in virgin NR and styrene butadiene rubber (SBR) matrices at 2, 4, 8 and 16 phr concentration. Addition of the gels improved the mechanical and dynamic mechanical properties of NR and SBR considerably. For example, 16 phr of 20 kGy EB-irradiated gel-filled NR showed a tensile strength of 3.53 MPa compared to 1.85 MPa of virgin NR. Introduction of gels in NR shifted the glass transition temperature to a higher temperature. A similar effect was observed in the case of NR gel-filled SBR systems. Morphology of the gel-filled systems was studied with atomic force microscopy. The NR gels also improved the processability of the virgin rubbers greatly. Both the shear viscosity and the die swell values of EB-irradiated gel-filled NR and SBR were lower than their virgin counterparts as investigated by capillary rheometer.

  2. Entanglement transfer from electrons to photons in quantum dots: an open quantum system approach

    International Nuclear Information System (INIS)

    Budich, Jan C; Trauzettel, Bjoern

    2010-01-01

    We investigate entanglement transfer from a system of two spin-entangled electron-hole pairs, each placed in a separate single mode cavity, to the photons emitted due to cavity leakage. Dipole selection rules and a splitting between the light hole and the heavy hole subbands are the crucial ingredients establishing a one-to-one correspondence between electron spins and circular photon polarizations. To account for the measurement of the photons as well as dephasing effects, we choose a stochastic Schroedinger equation and a conditional master equation approach, respectively. The influence of interactions with the environment as well as asymmetries in the coherent couplings on the photon entanglement is analysed for two concrete measurement schemes. The first one is designed to violate the Clauser-Horne-Shimony-Holt (CHSH) inequality, while the second one employs the visibility of interference fringes to prove the entanglement of the photons. Because of the spatial separation of the entangled electronic system over two quantum dots, a successful verification of entangled photons emitted by this system would imply the detection of nonlocal spin entanglement of massive particles in a solid state structure.

  3. Luminescent Eu3+ doped Al6Ge2O13 crystalline compounds obtained by the sol gel process for photonics

    Science.gov (United States)

    Maia, Lauro J. Q.; Faria Filho, Fausto M.; Gonçalves, Rogéria R.; Ribeiro, Sidney J. L.

    2018-01-01

    We synthesized pure and Eu3+ doped Al6Ge2O13 samples by an easy and low-cost sol-gel route using the GeO2, Al(NO3)3·9H2O and Eu(NO3)3·6H2O as precursors, tetramethylammonium hydroxide and ethanol as solvents. The Al6Ge2O13 crystalline phase possesses orthorhombic structure and is a potential host for rare earth ions, especially due to high aluminum concentration. Homogeneous and transparent sols and gels were obtained. The samples containing 1 mol% of Eu3+ were heat-treated at 1000 °C to eliminate organic compounds, providing high optical quality and structural purity. All materials were characterized by thermogravimetric and differential thermal analysis, X-ray diffraction, Fourier transform infrared spectroscopy, high resolution transmission electron microscopy, selected area electron diffraction, diffuse reflectance spectra in the ultraviolet-visible-near infrared regions and photoluminescence measurements. High purity of Eu3+ doped Al6Ge2O13 orthorhombic phase and well crystallized grain dimensions of around 100 nm was obtained with high red photoluminescence emission. The decay lifetime of 5D0 level from Eu3+ (the emission at 612 nm) was determined, being between 0.97 and 2.12 ms, and an average quantum efficiency of 54% was determined (considering the average experimental lifetime of 1.77 ms). Moreover, it was calculated and analyzed some parameters of Judd-Ofelt theory applied to Eu3+ emissions from Al6Ge2O13 host. The results show that Eu3+ doped Al6Ge2O13 crystalline compounds have large potential to be used in displays and LED devices.

  4. Comparison of the PCI distortion effects on the Auger lineshape for electron and photon impact ionization

    International Nuclear Information System (INIS)

    Paripas, B.; Vitez, G.; Vikor, Gy.; Tokesi, K.; Sankari, R.; Calo, A.

    2005-01-01

    The distortion effects of the post-collision interaction (PCI) on the Ar LMM Auger electron lineshape for electron and photon impact ionization have been calculated. The calculations were based on the eikonal model of Kuchiev and Sheinerman [Sov. Phys. - Tech. Phys. 32 (1987) 879]. It is shown that the Auger peak asymmetry depends on the emission angle of the Auger electron relative to the primary beam (and the polarization vector of the photon beam). At a given excess energy, defined as the difference between the impact energy and the binding energy, the absolute value of the Auger peak asymmetry is always larger for electron impact ionization than for photoionization. At the same time, the angular dependence of the PCI distortion is stronger for photoionization. In both cases the Auger peak asymmetry has a maximum when the energy of the ejected electron and that of the Auger electron are nearly equal. The calculations are in good agreement with our previous experimental results

  5. SPHERE: a spherical-geometry multimaterial electron/photon Monte Carlo transport code

    International Nuclear Information System (INIS)

    Halbleib, J.A. Sr.

    1977-06-01

    SPHERE provides experimenters and theorists with a method for the routine solution of coupled electron/photon transport through multimaterial configurations possessing spherical symmetry. Emphasis is placed upon operational simplicity without sacrificing the rigor of the model. SPHERE combines condensed-history electron Monte Carlo with conventional single-scattering photon Monte Carlo in order to describe the transport of all generations of particles from several MeV down to 1.0 and 10.0 keV for electrons and photons, respectively. The model is more accurate at the higher energies, with a less rigorous description of the particle cascade at energies where the shell structure of the transport media becomes important. Flexibility of construction permits the user to tailor the model to specific applications and to extend the capabilities of the model to more sophisticated applications through relatively simple update procedures. 8 figs., 3 tables

  6. PENELOPE, and algorithm and computer code for Monte Carlo simulation of electron-photon showers

    Energy Technology Data Exchange (ETDEWEB)

    Salvat, F.; Fernandez-Varea, J.M.; Baro, J.; Sempau, J.

    1996-10-01

    The FORTRAN 77 subroutine package PENELOPE performs Monte Carlo simulation of electron-photon showers in arbitrary for a wide energy range, from similar{sub t}o 1 KeV to several hundred MeV. Photon transport is simulated by means of the standard, detailed simulation scheme. Electron and positron histories are generated on the basis of a mixed procedure, which combines detailed simulation of hard events with condensed simulation of soft interactions. A simple geometry package permits the generation of random electron-photon showers in material systems consisting of homogeneous bodies limited by quadric surfaces, i.e. planes, spheres cylinders, etc. This report is intended not only to serve as a manual of the simulation package, but also to provide the user with the necessary information to understand the details of the Monte Carlo algorithm.

  7. PENELOPE, an algorithm and computer code for Monte Carlo simulation of electron-photon showers

    Energy Technology Data Exchange (ETDEWEB)

    Salvat, F.; Fernandez-Varea, J.M.; Baro, J.; Sempau, J.

    1996-07-01

    The FORTRAN 77 subroutine package PENELOPE performs Monte Carlo simulation of electron-photon showers in arbitrary for a wide energy range, from 1 keV to several hundred MeV. Photon transport is simulated by means of the standard, detailed simulation scheme. Electron and positron histories are generated on the basis of a mixed procedure, which combines detailed simulation of hard events with condensed simulation of soft interactions. A simple geometry package permits the generation of random electron-photon showers in material systems consisting of homogeneous bodies limited by quadric surfaces, i.e. planes, spheres, cylinders, etc. This report is intended not only to serve as a manual of the simulation package, but also to provide the user with the necessary information to understand the details of the Monte Carlo algorithm. (Author) 108 refs.

  8. GeV excess electrons upscattering the CMB: a possible resolution to the "Photon Underproduction Crisis"

    Science.gov (United States)

    Daylan, Tansu; Portillo, Stephen K. N.; Finkbeiner, Douglas P.

    2015-01-01

    Recently a gamma-ray excess has been identified in the inner Milky Way, which may be associated with the final state photon shower following DM annihilation to standard model final states. In this scenario ~ GeV electrons are also produced and, given their long energy loss timescale (~ Gyr), they can diffuse and escape the galaxy before losing too much energy. If such an electron population exists in the IGM, one observable consequence would be inverse Compton scattering on the CMB, which would produce UV photons that can efficiently ionize the IGM. This may be a possible resolution to the "Photon Underproduction Crisis", recently pointed out by Kollmeier et al. (2014). Regardless of the relevance to this crisis, the existence of a ~ GeV electron population in the IGM can put constraints on DM annihilation parameters considering the known X-ray backgrounds.

  9. Sources of electron contamination for the Clinac-35 25-MV photon beam

    International Nuclear Information System (INIS)

    Petti, P.L.; Goodman, M.S.; Sisterson, J.M.; Biggs, P.J.; Gabriel, T.A.; Mohan, R.

    1983-01-01

    A detailed Monte Carlo approach has been employed to investigate the sources of electron contamination for the 25-MV photon beam generated by Varian's Clinac-35. Three sources of contamination were examined: (a) the flattening filter and beam monitor chamber, (b) the fixed primary collimators downstream from the monitor chamber and the adjustable photon jaws, and (c) the air volume separating the treatment head from the observation point. Five source-to-surface distances (SSDs) were considered for a single field size, 28 cm in diameter at 80 cm SSD. It was found that for small SSDs (80-100 cm), the dominant sources of electron contamination were the flattening filter and the beam monitor chamber which accounted for 70% of the unwanted electrons. Thirteen percent of the remaining electrons originated in the downstream primary collimators and the photon jaws, and 17% were produced in air. At larger SSDs, the fraction of unwanted electrons originating in air increased. At 400 cm SSD, 61% of the contaminating electrons present in the beam were produced in air, 34% originated in the flattening filter and beam monitor chamber, and 5% were due to interactions in the fixed collimators downstream from the monitor chamber and the adjustable photon jaws. These calculated results are substantiated by recent experiments

  10. ITS - The integrated TIGER series of coupled electron/photon Monte Carlo transport codes

    International Nuclear Information System (INIS)

    Halbleib, J.A.; Mehlhorn, T.A.

    1985-01-01

    The TIGER series of time-independent coupled electron/photon Monte Carlo transport codes is a group of multimaterial, multidimensional codes designed to provide a state-of-the-art description of the production and transport of the electron/photon cascade. The codes follow both electrons and photons from 1.0 GeV down to 1.0 keV, and the user has the option of combining the collisional transport with transport in macroscopic electric and magnetic fields of arbitrary spatial dependence. Source particles can be either electrons or photons. The most important output data are (a) charge and energy deposition profiles, (b) integral and differential escape coefficients for both electrons and photons, (c) differential electron and photon flux, and (d) pulse-height distributions for selected regions of the problem geometry. The base codes of the series differ from one another primarily in their dimensionality and geometric modeling. They include (a) a one-dimensional multilayer code, (b) a code that describes the transport in two-dimensional axisymmetric cylindrical material geometries with a fully three-dimensional description of particle trajectories, and (c) a general three-dimensional transport code which employs a combinatorial geometry scheme. These base codes were designed primarily for describing radiation transport for those situations in which the detailed atomic structure of the transport medium is not important. For some applications, it is desirable to have a more detailed model of the low energy transport. The system includes three additional codes that contain a more elaborate ionization/relaxation model than the base codes. Finally, the system includes two codes that combine the collisional transport of the multidimensional base codes with transport in macroscopic electric and magnetic fields of arbitrary spatial dependence

  11. 3D electron tomography of biological photonic crystals

    Energy Technology Data Exchange (ETDEWEB)

    Butz, Benjamin; Winter, Benjamin; Vieweg, Benito; Knoke, Isabel; Spallek, Stefanie; Spiecker, Erdmann [CENEM, Universitaet Erlangen-Nuernberg (Germany); Schroeder-Turk, Gerd; Mecke, Klaus [Theoretische Physik I, Universitaet Erlangen-Nuernberg (Germany)

    2011-07-01

    Photonic crystals, i.e. periodical nanostructures of materials with different dielectric constants, are highly interesting for applications in optics, optoelectronics, and sensing. By tailoring the geometrical parameters radically different and improved optical properties (e.g., optical band-gap structure, extreme refractive indices, or high anisotropy) can be achieved. Naturally occurring photonic crystals, like butterfly scales, exoskeletons of insects (chitin), or seashells (nacre), can serve as model systems for understanding the relationship between structure and optical properties. Butterfly scales are studied by TEM using a FEI Titan{sup 3} 80-300 instrument. An optimized FIB technique or ultramicrotome sectioning were used to prepare the sensitive specimens with desired thickness. Since the periodical structures have dimensions on the sub-{mu}m scale, HAADF-STEM tomography was employed for obtaining extended tilt series under conditions of atomic-number sensitive imaging. Since the solid crystal consists of chemically homogeneous chitin while the pores are unfilled, the distinct contrast in the images can easily be interpreted in terms of the local projected mass density allowing to reconstruct the chitin distribution within the optical unit cell of the scales with high 3D resolution.

  12. SU-E-T-238: Deriving Electron Contamination Spectra From Pure and Clinical Photon Beams

    International Nuclear Information System (INIS)

    Smit, C; Plessis, F du

    2015-01-01

    Purpose: To extract the electron contamination energy spectra for an Elekta Precise Linac, based on pure photon and measured clinical beam percentage depth dose data. And to include this as an additional source in isource 4 in DOSXYZnrc. Methods: A pure photon beam was simulated for the Linac using isource 4 in the DOSXYZnrc Monte Carlo (MC) code. Percentage depth dose (PDD) data were extracted afterwards for a range of field sizes (FS). These simulated dose data were compared to actual measured dose PDD data, with the data normalized at 10 cm depth. The resulting PDD data resembled the electron contamination depth dose. Since the dose fall-off is a strictly decreasing function, a method was adopted to derive the contamination electron spectrum. Afterwards this spectrum was used in a DOSXYZnrc MC simulation run to verify that the original electron depth dose could be replicated. Results: Various square aperture FS’s for 6, 8 and 15 megavolt (MV) photon beams were modeled, simulated and compared to their respective actual measured PDD data. As FS increased, simulated pure photon depth-dose profiles shifted deeper, thus requiring electron contamination to increase the surface dose. The percentage of electron weight increased with increase in FS. For a FS of 15×15 cm 2 , the percentage electron weight is 0.1%, 0.2% and 0.4% for 6, 8 and 15 MV beams respectively. Conclusion: From the PDD results obtained, an additional electron contamination source was added to the photon source model so that simulation and measured PDD data could match within 2 % / 2 mm gamma-index criteria. The improved source model could assure more accurate simulations of surface doses. This research project was funded by the South African Medical Research Council (MRC) with funds from National Treasury under its Economic Competitiveness and Support package

  13. Advanced photonic, electronic, and web engineering systems: WILGA Symposium, January 2013

    Science.gov (United States)

    Romaniuk, Ryszard S.

    2013-10-01

    The cycle of WILGA Symposia [wilga.ise.pw.edu.pl] on Photonics and Web Engineering, Advanced Electronic Systems, under the auspices of SPIE, IEEE, KEiT PAN and WEiTI PW was initiated in 1998 by a Research Team PERG/ELHEP ISE PW. The WILGA conferences take place two times a year and the participants are young scientists from this country and abroad. This paper debates chosen topical tracks and some papers presented during the 31 WILGA Multi-Conference, which took place on 8-10 February 2013 at the Faculty of WEiTI PW. The January conference was attended by around 100 persons. Here we discuss closer the subjects of biomedical photonics, electronics and informatics, as well as chosen aspects of applications of advanced photonic, electronic circuits and systems. The 32 nd WILGA Symposium took place on 27 May - 02 June 2013 in WUT WILGA resort near Warsaw. These two editions of WILGA Conferences - January and May have generated more than 250 articles, from which around 100 were chosen by the Symposium and Conference Committees to be published in this volume of Proc.SPIE. WILGA Symposium papers are traditionally submitted via the WILGA web page [wilga.ise.pw.edu.pl] to the SPIE Proceedings publishing system [spie.org]. Email for the correspondence is: photonics@ise.pw.edu.pl. All Wilga papers are published in journals Elektronika, IJET-PAN and in Proc.SPIE. Topical tracks of the symposium usually embrace, among others, new technologies for photonics, sensory and nonlinear optical fibers, object oriented design of hardware, photonic metrology, optoelectronics and photonics applications, photonics-electronics co-design, optoelectronic and electronic systems for astronomy and high energy physics experiments, JET and pi-of-the sky experiments development. The symposium In its two editions a year is a summary of the development of numerable Ph.D. theses carried out in this country and this geographical region in the area of advanced electronic and photonic systems. It is also

  14. Scanning electron microscopy study of protein immobilized on SIO2 Sol-gel surfaces

    Directory of Open Access Journals (Sweden)

    Assis O.B.G.

    2003-01-01

    Full Text Available Uniform attachment of enzymes to solid surfaces is essential in the development of bio and optical sensor devices. Immobilization by adsorption according to hydrophilic or hydrophobic nature is dependent on the charges and defects of the support surfaces. Sol-gel SiO2 densified glass surfaces, frequently used as supports for protein immobilization, are evaluated via scanning electron microscopy. The model protein is globular enzyme lysozyme, deposited by adsorption on functionalized surfaces. Formation of a protein layer is confirmed by FTIR spectroscopy, and the SEM images suggest discontinuous adsorption in areas where cracks predominate on the glass surface.

  15. Search for New Physics in Electron-Positron Interactions with Photons in the Final State

    CERN Document Server

    Ruschmeier, D

    1999-01-01

    This thesis describes a measurement of single and multi-photon events with missing energy in electron-positron interactions. The results have been used to measure the neutrino pair-production cross section and to determine the number of light neutrino species. A search for various kinds of new physics processes involving photons and missing energy in the final state like the production of supersymmetric particles, a fermiophobic Higgs boson and massive gravitons has been carried out. The analysis has been performed using data collected with the L3 detector at LEP at centre-of-mass energies between 130 GeV and 190 GeV corresponding to a total luminosity of 265 1/pb. The cross section of the process electron positron to neutrino anti-neutrino photon (photon) for a photon energy larger than 5 GeV and a photon scattering angle with respect to the beam axis larger than 14 degrees at a centre-of-mass energy of 189 GeV has been measured to be (5.25 +- 0.22 +- 0.07) pb and has been extrapolated to a total cross secti...

  16. Detection of Infrared Photons Using the Electronic Stress in Metal-Semiconductor Interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Datskos, P.G.; Datskou, I.; Egert, C.M.; Rjic, S.

    1999-04-05

    It is well known that the work function of metals decreases when they are placed in a nonpolar liquid. A similar decrease occurs when the metal is placed into contact with a semiconductor forming a Schottky barrier. We report on a new method for detecting photons using the stress caused by photo-electrons emitted from a metal film surface in contact with a semiconductor microstructure. The photoelectrons diffuse into the microstructure and produce an electronic stress. The photon detection results from the measurement of the photo-induced bending of the microstructure. Internal photoemission has been used in the past to detect photons, however, in those cases the detection was accomplished by measuring the current due to photoelectrons and not due to electronic stress. Small changes in position (displacement) of microstructures are routinely measured in atomic force microscopy (AFM) where atomic imaging of surfaces relies on the measurement of small changes (< l0{sup -9} m) in the bending of microcantilevers. In the present work we studied the photon response of Si microcantilevers coated with a thin film of Pt. The Si microcantilevers were 500 nm thick and had a 30 nm layer of Pt. Photons with sufficient energies produce electrons from the platinum-silicon interface which diffuse into the Si and produce an electronic stress. Since the excess charge carriers cause the Si microcantilever to contract in length but not the Pt layer, the bimaterial microcantilever bends. In our present studies we used the optical detection technique to measure the photometric response of Pt-Si microcantilevers as a function of photon energy. The charge carriers responsible for the photo-induced stress in Si, were produced via internal photoemission using a diode laser with wavelength {lambda} = 1550 nm.

  17. Dosimetric characterization of VIPARnd gel by optical analysis to high-energy photon beam used in external radiotherapy; Caracterizacao dosimetrica de gel tipo VIPARnd atraves de analise optica para feixes de fotons de alta energia usado em radioterapia externa

    Energy Technology Data Exchange (ETDEWEB)

    Dias, Juliana R.; Lima, Renata S.; Lopes, Roseany de V. Vieira; Ceschin, Artemis Marti, E-mail: juliana_rdias@yahoo.com.br [Universidade de Brasilia (UnB), Brasilia, DF (Brazil)

    2015-07-01

    Polymer gel dosimetry has been proposed as a possibility for measurements of dose distribution in radiotherapy. This work aims to evaluate the dosimetric characteristics of a VIPARnd for 6 MV photon beam used in radiotherapy using optical investigations. The absorbance spectrum of irradiated gel dosimeter was optical evaluated with spectrophotometer techniques and with CMOS camera readout for dose range of 0 to 50 Gy. Data shows that the VIPARnd has a maximum absorbance at 300 to 320 nm depending on the absorbed dose. The CMOS camera readouts were obtained in RGB color, the absorbance measurements suggest a major response of dose for blue matrix verified with data. The dose-response curve for blue component showed interval of linearity from 1 Gy to 20 Gy. (author)

  18. Metrology and quality of radiation therapy dosimetry of electron, photon and epithermal neutron beams

    Energy Technology Data Exchange (ETDEWEB)

    Kosunen, A

    1999-08-01

    In radiation therapy using electron and photon beams the dosimetry chain consists of several sequential phases starting by the realisation of the dose quantity in the Primary Standard Dosimetry Laboratory and ending to the calculation of the dose to a patient. A similar procedure can be described for the dosimetry of epithermal neutron beams in boron neutron capture therapy (BNCT). To achieve the required accuracy of the dose delivered to a patient the quality of all steps in the dosimetry procedure has to be considered. This work is focused on two items in the dosimetry chains: the determination of the dose in the reference conditions and the evaluation of the accuracy of dose calculation methods. The issues investigated and discussed in detail are: a)the calibration methods of plane parallel ionisation chambers used in electron beam dosimetry, (b) the specification of the critical dosimetric parameter i.e. the ratio of stopping powers for water to air, (S I ?){sup water} {sub air}, in photon beams, (c) the feasibility of the twin ionization chamber technique for dosimetry in epithermal neutron beams applied to BNCT and (d) the determination accuracy of the calculated dose distributions in phantoms in electron, photon, and epithermal neutron beams. The results demonstrate that up to a 3% improvement in the consistency of dose determinations in electron beams is achieved by the calibration of plane parallel ionisation chambers in high energy electron beams instead of calibrations in {sup 60}Co gamma beams. In photon beam dosimetry (S I ?){sup water} {sub air} can be determined with an accuracy of 0.2% using the percentage dose at the 10 cm depth, %dd(10), as a beam specifier. The use of %odd(10) requires the elimination of the electron contamination in the photon beam. By a twin ionisation chamber technique the gamma dose can be determined with uncertainty of 6% (1 standard deviation) and the total neutron dose with an uncertainty of 15 to 20% (1 standard deviation

  19. Metrology and quality of radiation therapy dosimetry of electron, photon and epithermal neutron beams

    International Nuclear Information System (INIS)

    Kosunen, A.

    1999-08-01

    In radiation therapy using electron and photon beams the dosimetry chain consists of several sequential phases starting by the realisation of the dose quantity in the Primary Standard Dosimetry Laboratory and ending to the calculation of the dose to a patient. A similar procedure can be described for the dosimetry of epithermal neutron beams in boron neutron capture therapy (BNCT). To achieve the required accuracy of the dose delivered to a patient the quality of all steps in the dosimetry procedure has to be considered. This work is focused on two items in the dosimetry chains: the determination of the dose in the reference conditions and the evaluation of the accuracy of dose calculation methods. The issues investigated and discussed in detail are: a)the calibration methods of plane parallel ionisation chambers used in electron beam dosimetry, (b) the specification of the critical dosimetric parameter i.e. the ratio of stopping powers for water to air, (S I ?) water air , in photon beams, (c) the feasibility of the twin ionization chamber technique for dosimetry in epithermal neutron beams applied to BNCT and (d) the determination accuracy of the calculated dose distributions in phantoms in electron, photon, and epithermal neutron beams. The results demonstrate that up to a 3% improvement in the consistency of dose determinations in electron beams is achieved by the calibration of plane parallel ionisation chambers in high energy electron beams instead of calibrations in 60 Co gamma beams. In photon beam dosimetry (S I ?) water air can be determined with an accuracy of 0.2% using the percentage dose at the 10 cm depth, %dd(10), as a beam specifier. The use of %odd(10) requires the elimination of the electron contamination in the photon beam. By a twin ionisation chamber technique the gamma dose can be determined with uncertainty of 6% (1 standard deviation) and the total neutron dose with an uncertainty of 15 to 20% (1 standard deviation). To improve the accuracy

  20. Electron-photon angular correlation measurements for the 2 1P state of helium

    International Nuclear Information System (INIS)

    Slevin, J.; Porter, H.Q.; Eminyan, M.; Defrance, A.; Vassilev, G.

    1980-01-01

    Electron-photon angular correlations have been measured by detecting in delayed coincidence, electrons inelastically scattered from helium and photons emitted in decays from the 2 1 P state at incident electron energies of 60 and 80 eV. Analysis of the data yields values for the ratio lambda of the differential cross sections for magnetic sublevel excitations and the phase difference X between the corresponding probability amplitudes. The measurements extend over the angular range 10-120 0 of electron scattering angles. The present data are in good agreement with the experimental results of Hollywood et al, (J. Phys. B.; 12: 819 (1979)), and show a marked discrepancy at large scattering angles with the recent data of Steph and Golde. (Phys. Rev.; A in press (1980)). The experimental results are compared with some recent theories. (author)

  1. Evaluation of the photon monitor backscatter in medical electron accelerators

    International Nuclear Information System (INIS)

    Zrenner, M.; Krieger, H.

    1999-01-01

    Background: Modern linear accelerators permit the use of irregular fields due to their flexible collimator systems with separately movable jaws or multileaf collimators. When using such irregular fields in the clinical practice output factors have to be corrected for enhanced backscatter to the dose monitor as compared with the conventional block shieldings. Methods: A method is presented to detect the monitor backscatter contributions to the output factor for irregular field settings. Results: The monitor backscatter factors have been measured using a telescopic device for 2 different treatment head geometries (Varian Clinac 2100C/D, General Electric Saturne 15) and for 3 photon radiation qualities (nominal energies X6, X18, X12). A method is introduced to calculate the monitor backscatter for arbitrary irregular treatment fields from the experimental data for square or rectangular fields. Conclusions: Besides the corrections for changes in phantom scatter and changes in the aperture, corrections for monitor backscatter have to be taken into account in many clinical cases. They can contribute up to more than 10% compared with the monitor values for free regular fields. (orig.) [de

  2. Electron and photon energy calibration with the ATLAS detector using LHC Run 1 data

    Czech Academy of Sciences Publication Activity Database

    Aad, G.; Abbott, B.; Abdallah, J.; Böhm, Jan; Chudoba, Jiří; Havránek, Miroslav; Hejbal, Jiří; Jakoubek, Tomáš; Kepka, Oldřich; Kupčo, Alexander; Kůs, Vlastimil; Lokajíček, Miloš; Lysák, Roman; Marčišovský, Michal; Mikeštíková, Marcela; Němeček, Stanislav; Šícho, Petr; Staroba, Pavel; Svatoš, Michal; Taševský, Marek; Vrba, Václav

    2014-01-01

    Roč. 74, č. 10 (2014), "3071-1"-"3071-48" ISSN 1434-6044 R&D Projects: GA MŠk(CZ) LG13009 Institutional support: RVO:68378271 Keywords : photon * energy * calibration * detector * resolution * showers * electromagnetic * electron * transverse energy * CERN LHC Coll * calorimeter Subject RIV: BF - Elementary Particles and High Energy Physics Impact factor: 5.084, year: 2014

  3. Convergence of photonics and electronics for Terahertz wireless communications – the ITN CELTA project

    DEFF Research Database (Denmark)

    Tafur Monroy, Idelfonso

    2016-01-01

    Terahertz wireless communications is expected to offer the required high capacity and low latency performance required from short-range wireless access and control applications. We present an overview of some the activities in this area in the newly started H2020 ITN project CELTA: convergence of...... of electronics and photonics technologies enabling Terahertz applications...

  4. Electron energy spectrum and maximum disruption angle under multi-photon beamstrahlung

    Energy Technology Data Exchange (ETDEWEB)

    Yokoya, Kaoru; Chen, Pisin

    1989-03-01

    The final electron energy spectrum under multi-photon beamstrahlung process is derived analytically in the classical and the intermediate regimes. The maximum disruption angle from the low energy tail of the spectrum is also estimated. The results are then applied to the TLC and the CLIC parameters. 6 refs., 1 fig., 1 tab.

  5. Evidence for resonance electron transfer in photon excited X-ray ...

    Indian Academy of Sciences (India)

    with the experimental values and (3) to compare the experimental values obtained by photon excitation with those measured by electron excitation in the available cases. 2. Experimental details. In the present investigations, a Philips 1410 wavelength dispersive plane crystal spectrometer was used. The principle involved ...

  6. Evidence for resonance electron transfer in photon excited X-ray ...

    Indian Academy of Sciences (India)

    Evidence for resonance electron transfer in photon excited X-ray satellite spectra of fluorine compounds. K Ram Narayana B Seetharami Reddy S S Raju T Seshi Reddy S Lakshmi Narayana K Premachand B M Rao M V R Murti L S Mombasawala. Research Articles Volume 65 Issue 2 August 2005 pp 285-290 ...

  7. QCD corrections to single top quark production in electron-photon interactions

    CERN Document Server

    Kühn, J H; Uwer, Peter

    2003-01-01

    Single top quark production in electron-photon interactions provides a clean environment for the measurement of the Cabibbo-Kobayashi-Maskawa matrix element V sub t sub b. Aiming at an experimental precision at the percent level the knowledge of radiative corrections is important. In this paper we present results for the radiative corrections in quantum chromodynamics. (orig.)

  8. Establishing the impact of temporary tissue expanders on electron and photon beam dose distributions.

    Science.gov (United States)

    Asena, A; Kairn, T; Crowe, S B; Trapp, J V

    2015-05-01

    This study investigates the effects of temporary tissue expanders (TTEs) on the dose distributions in breast cancer radiotherapy treatments under a variety of conditions. Using EBT2 radiochromic film, both electron and photon beam dose distribution measurements were made for different phantoms, and beam geometries. This was done to establish a more comprehensive understanding of the implant's perturbation effects under a wider variety of conditions. The magnetic disk present in a tissue expander causes a dose reduction of approximately 20% in a photon tangent treatment and 56% in electron boost fields immediately downstream of the implant. The effects of the silicon elastomer are also much more apparent in an electron beam than a photon beam. Evidently, each component of the TTE attenuates the radiation beam to different degrees. This study has demonstrated that the accuracy of photon and electron treatments of post-mastectomy patients is influenced by the presence of a tissue expander for various beam orientations. The impact of TTEs on dose distributions establishes the importance of an accurately modelled high-density implant in the treatment planning system for post-mastectomy patients. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  9. Theory of photon and electron induced reactions: Progress report, July 1, 1986-June 30, 1987

    International Nuclear Information System (INIS)

    Onley, D.S.; Wright, L.E.

    1988-07-01

    During the third year of our three-year contract from the Department of Energy, we have made considerable progress or have completed our studies on the following aspects of the general investigation of electron and photon induced reactions; photo- and electro-production of mesons; the radiation tail accompanying elastic electron scattering and pair production; studies involving relativistic shell model; and electrofission coincidence angular distributions. We will report on each of these developments in this paper

  10. Tagging system for scattered electrons in two-photon reactions at the MD-1 detector

    International Nuclear Information System (INIS)

    Aul'chenko, V.M.; Baru, S.E.; Blinov, A.E.

    1994-01-01

    The Tagging System of the MD-1 detector at the VEPP-4 collider used for studying of two-photon reactions is described. A transverse magnetic field enables one to detect scattered electrons and positrons even at zero scattering angles. The system energy resolution for scattered electron is 1.75% at the beam energy 4.7 GeV. 32 refs.; 21 figs.; 1 tabs

  11. A systematic review of the precision and accuracy of dose measurements in photon radiotherapy using polymer and Fricke MRI gel dosimetry

    International Nuclear Information System (INIS)

    MacDougall, N.D.; Pitchford, W.G.; Smith, M.A.

    2002-01-01

    The purpose of this work is to undertake a critical appraisal of the evidence in the published literature concerning the basic parameters of accuracy and precision associated with the use of Fricke and polymer gels (in conjunction with MR imaging) as radiation dosimeters in photon radiotherapy, condensing and analysing the body of published information (to the end of April 2002). A systematic review was undertaken addressing specific issues of precision and accuracy asking defined questions of the published literature. Accuracy and precision in relation to gel dosimetry were defined. Information was obtained from published, peer-reviewed journals. A defined search strategy utilizing MeSH headings and keywords, with extensive use of cross-referencing, identified 115 references dealing with gel dosimetry. Exclusion criteria were used to select only data from publications which would give unequivocal evidence. For accuracy, results had to be compared with an ionization chamber as gold standard and all gel samples had to be manufactured in the same batch. For precision, in addition to gels being from the same batch, samples must all have been irradiated at the same time and scanned simultaneously (or within a short time frame). Many results were found demonstrating 'dose mapping' examples using gels. However, there were very few publications containing firm evidence of precision and accuracy. There was no evidence which fulfilled our criteria about accuracy or precision using Fricke gels. For polymer gels only one paper was found for accuracy (4% (Low et al 1999 Med. Phys. 26 1542-51)) and precision (1.7% (Baldock et al 1998 Phys. Med. Biol. 43 695-702)); however, both were carried out at only one dose level. If the exclusion criteria were relaxed to include accuracy results comparing gel to a non gold standard dosimeter (e.g. TLD), results give a median accuracy of 10% (range 8-23.5%) for polymer gel (Cosgrove et al 2000 Phys. Med. Biol. 45 1195-210, De Deene et al

  12. Results on the Coherent Interaction of High Energy Electrons and Photons in Oriented Single Crystals

    CERN Document Server

    Apyan, A.; Badelek, B.; Ballestrero, S.; Biino, C.; Birol, I.; Cenci, P.; Connell, S.H.; Eichblatt, S.; Fonseca, T.; Freund, A.; Gorini, B.; Groess, R.; Ispirian, K.; Ketel, T.J.; Kononets, Yu.V.; Lopez, A.; Mangiarotti, A.; van Rens, B.; Sellschop, J.P.F.; Shieh, M.; Sona, P.; Strakhovenko, V.; Uggerhoj, E.; Uggerhj, Ulrik Ingerslev; Unel, G.; Velasco, M.; Vilakazi, Z.Z.; Wessely, O.; Kononets, Yu.V.

    2005-01-01

    The CERN-NA-59 experiment examined a wide range of electromagnetic processes for multi-GeV electrons and photons interacting with oriented single crystals. The various types of crystals and their orientations were used for producing photon beams and for converting and measuring their polarisation. The radiation emitted by 178 GeV unpolarised electrons incident on a 1.5 cm thick Si crystal oriented in the Coherent Bremsstrahlung (CB) and the String-of-Strings (SOS) modes was used to obtain multi-GeV linearly polarised photon beams. A new crystal polarimetry technique was established for measuring the linear polarisation of the photon beam. The polarimeter is based on the dependence of the Coherent Pair Production (CPP) cross section in oriented single crystals on the direction of the photon polarisation with respect to the crystal plane. Both a 1 mm thick single crystal of Germanium and a 4 mm thick multi-tile set of synthetic Diamond crystals were used as analyzers of the linear polarisation. A birefringence ...

  13. Electron/photon matched field technique for treatment of orbital disease

    International Nuclear Information System (INIS)

    Arthur, Douglas W.; Zwicker, Robert D.; Garmon, Pamela W.; Huang, David T.; Schmidt-Ullrich, Rupert K.

    1997-01-01

    Purpose: A number of approaches have been described in the literature for irradiation of malignant and benign diseases of the orbit. Techniques described to date do not deliver a homogeneous dose to the orbital contents while sparing the cornea and lens of excessive dose. This is a result of the geometry encountered in this region and the fact that the target volume, which includes the periorbital and retroorbital tissues but excludes the cornea, anterior chamber, and lens, cannot be readily accommodated by photon beams alone. To improve the dose distribution for these treatments, we have developed a technique that combines a low-energy electron field carefully matched with modified photon fields to achieve acceptable dose coverage and uniformity. Methods and Materials: An anterior electron field and a lateral photon field setup is used to encompass the target volume. Modification of these fields permits accurate matching as well as conformation of the dose distribution to the orbit. A flat-surfaced wax compensator assures uniform electron penetration across the field, and a sunken lead alloy eye block prevents excessive dose to the central structures of the anterior segment. The anterior edge of the photon field is modified by broadening the penumbra using a form of pseudodynamic collimation. Direct measurements using film and ion chamber dosimetry were used to study the characteristics of the fall-off region of the electron field and the penumbra of the photon fields. >From the data collected, the technique for accurate field matching and dose uniformity was generated. Results: The isodose curves produced with this treatment technique demonstrate homogeneous dose coverage of the orbit, including the paralenticular region, and sufficient dose sparing of the anterior segment. The posterior lens accumulates less than 40% of the prescribed dose, and the lateral aspect of the lens receives less than 30%. A dose variation in the match region of ±12% is confronted when

  14. Average stopping powers for electron and photon sources for radiobiological modeling and microdosimetric applications

    Science.gov (United States)

    Vassiliev, Oleg N.; Kry, Stephen F.; Grosshans, David R.; Mohan, Radhe

    2018-03-01

    This study concerns calculation of the average electronic stopping power for photon and electron sources. It addresses two problems that have not yet been fully resolved. The first is defining the electron spectrum used for averaging in a way that is most suitable for radiobiological modeling. We define it as the spectrum of electrons entering the sensitive to radiation volume (SV) within the cell nucleus, at the moment they enter the SV. For this spectrum we derive a formula that combines linearly the fluence spectrum and the source spectrum. The latter is the distribution of initial energies of electrons produced by a source. Previous studies used either the fluence or source spectra, but not both, thereby neglecting a part of the complete spectrum. Our derived formula reduces to these two prior methods in the case of high and low energy sources, respectively. The second problem is extending electron spectra to low energies. Previous studies used an energy cut-off on the order of 1 keV. However, as we show, even for high energy sources, such as 60Co, electrons with energies below 1 keV contribute about 30% to the dose. In this study all the spectra were calculated with Geant4-DNA code and a cut-off energy of only 11 eV. We present formulas for calculating frequency- and dose-average stopping powers, numerical results for several important electron and photon sources, and tables with all the data needed to use our formulas for arbitrary electron and photon sources producing electrons with initial energies up to  ∼1 MeV.

  15. Single-photon emission correlated to double-electron capture by bare ions: background processes

    Science.gov (United States)

    Elkafrawy, T.; Warczak, A.; Simon, A.; Tanis, J. A.

    2013-09-01

    Radiative single- and double-electron capture are one-step processes where a single target electron or two target electrons, respectively, are captured to a bound state of a highly charged projectile with the simultaneous emission of a single photon. In ion-atom collisions, several background processes are likely to contribute to these processes and may interfere with the measured x-rays due to radiative single and double capture. In this study, possible contributions from radiative electron capture to the continuum, secondary electron bremsstrahlung, the two-step process of independent double radiative electron capture, as well as radiative- combined with nonradiative-electron capture are taken into account based on our analysis of the data for 2.21 MeV u-1 F9+ ions colliding with a thin carbon foil.

  16. Photon- and electron-stimulated desorption from laboratory models of interstellar ice grains

    International Nuclear Information System (INIS)

    Thrower, J. D.; Abdulgalil, A. G. M.; Collings, M. P.; McCoustra, M. R. S.; Burke, D. J.; Brown, W. A.; Dawes, A.; Holtom, P. J.; Kendall, P.; Mason, N. J.; Jamme, F.; Fraser, H. J.; Rutten, F. J. M.

    2010-01-01

    The nonthermal desorption of water from ice films induced by photon and low energy electron irradiation has been studied under conditions mimicking those found in dense interstellar clouds. Water desorption following photon irradiation at 250 nm relies on the presence of an absorbing species within the H 2 O ice, in this case benzene. Desorption cross sections are obtained and used to derive first order rate coefficients for the desorption processes. Kinetic modeling has been used to compare the efficiencies of these desorption mechanisms with others known to be in operation in dense clouds.

  17. Application of the Arbitrarily High Order Method to Coupled Electron Photon Transport

    International Nuclear Information System (INIS)

    Duo, Jose Ignacio

    2004-01-01

    This work is about the application of the Arbitrary High Order Nodal Method to coupled electron photon transport.A Discrete Ordinates code was enhanced and validated which permited to evaluate the advantages of using variable spatial development order per particle.The results obtained using variable spatial development and adaptive mesh refinement following an a posteriori error estimator are encouraging.Photon spectra for clinical accelerator target and, dose and charge depositio profiles are simulated in one-dimensional problems using cross section generated with CEPXS code.Our results are in good agreement with ONELD and MCNP codes

  18. On mixed electron-photon radiation therapy optimization using the column generation approach.

    Science.gov (United States)

    Renaud, Marc-André; Serban, Monica; Seuntjens, Jan

    2017-08-01

    Despite considerable increase in the number of degrees of freedom handled by recent radiotherapy optimisation algorithms, treatments are still typically delivered using a single modality. Column generation is an iterative method for solving large optimisation problems. It is well suited for mixed-modality (e.g., photon-electron) optimisation as the aperture shaping and modality selection problem can be solved rapidly, and the performance of the algorithm scales favourably with increasing degrees of freedom. We demonstrate that the column generation method applied to mixed photon-electron planning can efficiently generate treatment plans and investigate its behaviour under different aperture addition schemes. Column generation was applied to the problem of mixed-modality treatment planning for a chest wall case and a leg sarcoma case. 6 MV beamlets (100 cm SAD) were generated for the photon components along with 5 energies for electron beamlets (6, 9, 12, 16 and 20 MeV), simulated as shortened-SAD (80 cm) beams collimated with a photon MLC. For the chest wall case, IMRT-only, modulated electron radiation therapy (MERT)-only, and mixed electron-photon (MBRT) treatment plans were created using the same planning criteria. For the sarcoma case, MBRT and MERT plans were created to study the behaviour of the algorithm under two different sets of planning criteria designed to favour specific modalities. Finally, the efficiency and plan quality of four different aperture addition schemes was analysed by creating chest wall MBRT treatment plans which incorporate more than a single aperture per iteration of the column generation loop based on a heuristic aperture ranking scheme. MBRT plans produced superior target coverage and homogeneity relative to IMRT and MERT plans created using the same optimisation criteria, all the while preserving the normal tissue-sparing advantages of electron therapy. Adjusting the planning criteria to favour a specific modality in the sarcoma

  19. Time-dependent density functional theory for many-electron systems interacting with cavity photons.

    Science.gov (United States)

    Tokatly, I V

    2013-06-07

    Time-dependent (current) density functional theory for many-electron systems strongly coupled to quantized electromagnetic modes of a microcavity is proposed. It is shown that the electron-photon wave function is a unique functional of the electronic (current) density and the expectation values of photonic coordinates. The Kohn-Sham system is constructed, which allows us to calculate the above basic variables by solving self-consistent equations for noninteracting particles. We suggest possible approximations for the exchange-correlation potentials and discuss implications of this approach for the theory of open quantum systems. In particular we show that it naturally leads to time-dependent density functional theory for systems coupled to the Caldeira-Leggett bath.

  20. Photon and electron interaction databases and their use in medical applications

    International Nuclear Information System (INIS)

    Cullen, D.E.

    1994-05-01

    This paper discusses the All Particle-Method photon and electron interaction, and atomic relaxation data bases, that were initially developed for use in medical applications. Currently these data bases are being used in both medical and industrial applications. The All Particle Method data bases are designed to allow modelling of individual collisions in as much detail as possible. Elastic scattering can be modelled as single, as opposed to multiple, scattering events. Ionization can be modelled at the atomic subshell level, to define which subshell was ionized, spectrum of the initially emitted electron, as well as the spectra of electron and photons emitted as the atom relaxes back to neutrality. These data bases are currently being used in applications involving rather small spatial regions, where detailed calculations of individual events are required. While initially designed for use in medical applications, these data bases are now being used in a variety of industrial applications, e.g., transport in microelectronics

  1. A novel radiation therapy technique for malignant pleural mesothelioma combining electrons with intensity-modulated photons

    International Nuclear Information System (INIS)

    Chan, Maria F.; Chui, Chen S.; Song Yulin; Burman, Chandra; Yorke, Ellen; Della-Biancia, Cesar; Rosenzweig, Kenneth E.; Schupak, Karen

    2006-01-01

    Background and purpose: To investigate the feasibility and potential benefits of combining electron and photon intensity modulated radiotherapy (IMRT) for patients with malignant pleural mesothelioma (MPM). Patients and methods: The planning CT images of 11 MPM patients, six after extrapleural pneumonectomy (EPP) and five after pleurectomy/decortication (P/D), were used for this study. These cases were planned with photon IMRT alone and photon IMRT combined with electrons (IMRT+e). The latter approach incorporated the electron dose into the inverse planning optimization. The resulting doses to the planning target volume (PTV) and relevant critical structures were compared. Results: For all patients, the PTV was well covered and doses to critical structures were clinically acceptable for all patients with both techniques. However, IMRT+e exhibited a distinct advantage in reducing the doses to the liver, ipsilateral kidney, contralateral kidney, and heart (P=0.002, 0.003, 0.025, and 0.001, respectively). Conclusions: This study showed that IMRT or IMRT+e is a viable treatment modality for MPM patients. Both plans can provide excellent target coverage and normal tissue sparing, but with the addition of electron beams, the critical structures can be further spared. Additional refining of the electron contribution is expected to further reduce radiation-induced morbidity

  2. Electron- and photon-impact ionization of furfural

    Energy Technology Data Exchange (ETDEWEB)

    Jones, D. B. [School of Chemical and Physical Sciences, Flinders University, GPO Box 2100, Adelaide, SA 5001 (Australia); Ali, E.; Madison, D. H., E-mail: plimaovieira@fct.unl.pt, E-mail: madison@mst.edu, E-mail: michael.brunger@flinders.edu.au [Department of Physics, Missouri University of Science and Technology, Rolla, Missouri 65409 (United States); Nixon, K. L. [Departamento de Física, Universidade Federal de Juiz de Fora, Juiz de Fora, MG (Brazil); School of Biology, Chemistry and Forensic Science, University of Wolverhampton, Wolverhampton WV1 1LY (United Kingdom); Limão-Vieira, P., E-mail: plimaovieira@fct.unl.pt, E-mail: madison@mst.edu, E-mail: michael.brunger@flinders.edu.au [Laboratório de Colisões Atómicas e Moleculares, CEFITEC, Departamento de Física, Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa, 2829-516 Caparica (Portugal); Hubin-Franskin, M.-J.; Delwiche, J. [Départment de Chimie, Université de Liège, Institut de Chimie-Bât. B6C, B-4000 Liège 1 (Belgium); Ning, C. G. [State Key Laboratory of Low-Dimensional Quantum Physics, Department of Physics, Tsinghua University, Beijing 100084 (China); Colgan, J. [Theoretical Division, Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Murray, A. J. [Photon Science Institute, School of Physics and Astronomy, University of Manchester, Manchester M13 9PL (United Kingdom); and others

    2015-11-14

    The He(I) photoelectron spectrum of furfural has been investigated, with its vibrational structure assigned for the first time. The ground and excited ionized states are assigned through ab initio calculations performed at the outer-valence Green’s function level. Triple differential cross sections (TDCSs) for electron-impact ionization of the unresolved combination of the 4a″  +  21a′ highest and next-highest occupied molecular orbitals have also been obtained. Experimental TDCSs are recorded in a combination of asymmetric coplanar and doubly symmetric coplanar kinematics. The experimental TDCSs are compared to theoretical calculations, obtained within a molecular 3-body distorted wave framework that employed either an orientation average or proper TDCS average. The proper average calculations suggest that they may resolve some of the discrepancies regarding the angular distributions of the TDCS, when compared to calculations employing the orbital average.

  3. Photon-Electron Interactions in Dirac Quantum Materials

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Xiaodong [Univ. of Washington, Seattle, WA (United States). Dept. of Material Science and Engineering

    2017-11-10

    The objective of this proposal was to explore the fundamental light-matter interactions in a new class of Dirac quantum materials, atomically thin transition metal dichalcogenides (TMDs). Monolayer TMDs are newly discovered two-dimensional semiconductors with direct bandgap. Due to their hexagonal lattice structure, the band edge localizes at corner of Brillouin zone, i.e. “Dirac valleys”. This gives the corresponding electron states a “valley index” (or pseudospin) in addition to the real spin. Remarkably, the valley pseudospins have circularly polarized optical selection rules, providing the first solid state system for dynamic control of the valley degree of freedom. During this award, we have developed a suite of advanced nano-optical spectroscopy tools in the investigation and manipulation of charge, spin, and valley degrees of freedom in monolayer semiconductors. Emerging physical phenomena, such as quantum coherence between valley pseudospins, have been demonstrated for the first time in solids. In addition to monolayers, we have developed a framework in engineering, formulating, and understanding valley pseudospin physics in 2D heterostructures formed by different monolayer semiconductors. We demonstrated long-lived valley-polarized interlayer excitons with valley-dependent many-body interaction effects. These works push the research frontier in understanding the light-matter interactions in atomically-thin quantum materials for protentional transformative energy technologies.

  4. Future prospects in photon and electron physics at Saclay

    International Nuclear Information System (INIS)

    Laget, J.M.

    1984-12-01

    In introduction the two nucleon system is considered. Their interaction is very well described at large distances by the pion exchange potential at intermediate distances by the exchange of two correlated pions. Between the exchange of these two pions, one of the nucleons, or both, can be transformed into a Δ. At small distances the exchange of vector mesons (rho, ω) plays a role, but it is also here that the quark structure of the nucleon is expected to enter the jame. Coincidence experiments performed with the electromagnetic probe are precisely the most strayhtforwad way to answer these questions. This is illustrated by spectra of the electrons inelastically scattered on 3 He which are good examples of the interplay between the many body aspects and the internal degrees of freedom of the nucleon. More exclusive experiments must be performed in order to single out each channel and study the various aspects of the nuclear dynamics. An example in each part of these response functions is given. The first one concerns the pion photoproduction at the top of the Δ peak and has to do with the NΔ interaction. The second concerns the creation of virtual pions near the threshold and has to do with the exchange currents. Typical example choosen is the deuteron electrodisintegration near the threshold when the electric is scattered at a given angle. The third one concern the study of the short range correlations by mean of the (e,e'N) and (e,e'NN) reactions

  5. Quantum mechanical simulations of polymers for molecular electronics and photonics

    International Nuclear Information System (INIS)

    Dupuis, M.; Villar, H.O.; Clementi, E.

    1987-01-01

    Ab initio quantum mechanical studies can play an important role in obtaining a detailed understanding of the electronic structure of existing materials, and in predicting the properties of new ones. In this article the authors give a general outline of their research activity in two areas dealing with new materials, specifically, conducting polymers and polymers with non-linear optical properties. The authors present the strategy followed for the study of these molecular systems, and an overview of their findings concerning the structure of the prototypical conducting polymer, i.e. pure and doped polyacetylene (PA). They focused attention on vibrational spectra and infrared and Raman intensities. The results of self-consistent-field (SCF) calculations on charged soliton-like molecules are consistent with experimental observation. In particular, they show that the theoretically established accidental mutual exclusion of infrared and Raman bands invalidates the requirement formulated on the basis of the interpretation of experimental data, that defects in PA must have local C/sub 2h/ symmetry. These conclusions are derived from extensive calculations for which supercomputer performance was imperative and carried out on the parallel supercomputer assembled at IBM-Kingston as a loosely coupled array of processors (LCAP). The authors briefly describe this computer system which has proven to be ideally suited to the methods of ab initio quantum chemistry

  6. Electron and photon energy calibration with the ATLAS detector using LHC Run 1 data

    CERN Document Server

    Aad, Georges; Abdallah, Jalal; Abdel Khalek, Samah; Abdinov, Ovsat; Aben, Rosemarie; Abi, Babak; Abolins, Maris; AbouZeid, Ossama; Abramowicz, Halina; Abreu, Henso; Abreu, Ricardo; Abulaiti, Yiming; Acharya, Bobby Samir; Adamczyk, Leszek; Adams, David; Adelman, Jahred; Adomeit, Stefanie; Adye, Tim; Agatonovic-Jovin, Tatjana; Aguilar-Saavedra, Juan Antonio; Agustoni, Marco; Ahlen, Steven; Ahmadov, Faig; Aielli, Giulio; Akerstedt, Henrik; Åkesson, Torsten Paul Ake; Akimoto, Ginga; Akimov, Andrei; Alberghi, Gian Luigi; Albert, Justin; Albrand, Solveig; Alconada Verzini, Maria Josefina; Aleksa, Martin; Aleksandrov, Igor; Alexa, Calin; Alexander, Gideon; Alexandre, Gauthier; Alexopoulos, Theodoros; Alhroob, Muhammad; Alimonti, Gianluca; Alio, Lion; Alison, John; Allbrooke, Benedict; Allison, Lee John; Allport, Phillip; Almond, John; Aloisio, Alberto; Alonso, Alejandro; Alonso, Francisco; Alpigiani, Cristiano; Altheimer, Andrew David; Alvarez Gonzalez, Barbara; Alviggi, Mariagrazia; Amako, Katsuya; Amaral Coutinho, Yara; Amelung, Christoph; Amidei, Dante; Amor Dos Santos, Susana Patricia; Amorim, Antonio; Amoroso, Simone; Amram, Nir; Amundsen, Glenn; Anastopoulos, Christos; Ancu, Lucian Stefan; Andari, Nansi; Andeen, Timothy; Anders, Christoph Falk; Anders, Gabriel; Anderson, Kelby; Andreazza, Attilio; Andrei, George Victor; Anduaga, Xabier; Angelidakis, Stylianos; Angelozzi, Ivan; Anger, Philipp; Angerami, Aaron; Anghinolfi, Francis; Anisenkov, Alexey; Anjos, Nuno; Annovi, Alberto; Antonaki, Ariadni; Antonelli, Mario; Antonov, Alexey; Antos, Jaroslav; Anulli, Fabio; Aoki, Masato; Aperio Bella, Ludovica; Apolle, Rudi; Arabidze, Giorgi; Aracena, Ignacio; Arai, Yasuo; Araque, Juan Pedro; Arce, Ayana; Arguin, Jean-Francois; Argyropoulos, Spyridon; Arik, Metin; Armbruster, Aaron James; Arnaez, Olivier; Arnal, Vanessa; Arnold, Hannah; Arratia, Miguel; Arslan, Ozan; Artamonov, Andrei; Artoni, Giacomo; Asai, Shoji; Asbah, Nedaa; Ashkenazi, Adi; Åsman, Barbro; Asquith, Lily; Assamagan, Ketevi; Astalos, Robert; Atkinson, Markus; Atlay, Naim Bora; Auerbach, Benjamin; Augsten, Kamil; Aurousseau, Mathieu; Avolio, Giuseppe; Azuelos, Georges; Azuma, Yuya; Baak, Max; Baas, Alessandra; Bacci, Cesare; Bachacou, Henri; Bachas, Konstantinos; Backes, Moritz; Backhaus, Malte; Backus Mayes, John; Badescu, Elisabeta; Bagiacchi, Paolo; Bagnaia, Paolo; Bai, Yu; Bain, Travis; Baines, John; Baker, Oliver Keith; Balek, Petr; Balli, Fabrice; Banas, Elzbieta; Banerjee, Swagato; Bannoura, Arwa A E; Bansal, Vikas; Bansil, Hardeep Singh; Barak, Liron; Baranov, Sergei; Barberio, Elisabetta Luigia; Barberis, Dario; Barbero, Marlon; Barillari, Teresa; Barisonzi, Marcello; Barklow, Timothy; Barlow, Nick; Barnett, Bruce; Barnett, Michael; Barnovska, Zuzana; Baroncelli, Antonio; Barone, Gaetano; Barr, Alan; Barreiro, Fernando; Barreiro Guimarães da Costa, João; Bartoldus, Rainer; Barton, Adam Edward; Bartos, Pavol; Bartsch, Valeria; Bassalat, Ahmed; Basye, Austin; Bates, Richard; Batley, Richard; Battaglia, Marco; Battistin, Michele; Bauer, Florian; Bawa, Harinder Singh; Beattie, Michael David; Beau, Tristan; Beauchemin, Pierre-Hugues; Beccherle, Roberto; Bechtle, Philip; Beck, Hans Peter; Becker, Anne Kathrin; Becker, Sebastian; Beckingham, Matthew; Becot, Cyril; Beddall, Andrew; Beddall, Ayda; Bedikian, Sourpouhi; Bednyakov, Vadim; Bee, Christopher; Beemster, Lars; Beermann, Thomas; Begel, Michael; Behr, Katharina; Belanger-Champagne, Camille; Bell, Paul; Bell, William; Bella, Gideon; Bellagamba, Lorenzo; Bellerive, Alain; Bellomo, Massimiliano; Belotskiy, Konstantin; Beltramello, Olga; Benary, Odette; Benchekroun, Driss; Bendtz, Katarina; Benekos, Nektarios; Benhammou, Yan; Benhar Noccioli, Eleonora; Benitez Garcia, Jorge-Armando; Benjamin, Douglas; Bensinger, James; Benslama, Kamal; Bentvelsen, Stan; Berge, David; Bergeaas Kuutmann, Elin; Berger, Nicolas; Berghaus, Frank; Beringer, Jürg; Bernard, Clare; Bernat, Pauline; Bernius, Catrin; Bernlochner, Florian Urs; Berry, Tracey; Berta, Peter; Bertella, Claudia; Bertoli, Gabriele; Bertolucci, Federico; Bertsche, Carolyn; Bertsche, David; Besana, Maria Ilaria; Besjes, Geert-Jan; Bessidskaia, Olga; Bessner, Martin Florian; Besson, Nathalie; Betancourt, Christopher; Bethke, Siegfried; Bhimji, Wahid; Bianchi, Riccardo-Maria; Bianchini, Louis; Bianco, Michele; Biebel, Otmar; Bieniek, Stephen Paul; Bierwagen, Katharina; Biesiada, Jed; Biglietti, Michela; Bilbao De Mendizabal, Javier; Bilokon, Halina; Bindi, Marcello; Binet, Sebastien; Bingul, Ahmet; Bini, Cesare; Black, Curtis; Black, James; Black, Kevin; Blackburn, Daniel; Blair, Robert; Blanchard, Jean-Baptiste; Blazek, Tomas; Bloch, Ingo; Blocker, Craig; Blum, Walter; Blumenschein, Ulrike; Bobbink, Gerjan; Bobrovnikov, Victor; Bocchetta, Simona Serena; Bocci, Andrea; Bock, Christopher; Boddy, Christopher Richard; Boehler, Michael; Boek, Thorsten Tobias; Bogaerts, Joannes Andreas; Bogdanchikov, Alexander; Bogouch, Andrei; Bohm, Christian; Bohm, Jan; Boisvert, Veronique; Bold, Tomasz; Boldea, Venera; Boldyrev, Alexey; Bomben, Marco; Bona, Marcella; Boonekamp, Maarten; Borisov, Anatoly; Borissov, Guennadi; Borri, Marcello; Borroni, Sara; Bortfeldt, Jonathan; Bortolotto, Valerio; Bos, Kors; Boscherini, Davide; Bosman, Martine; Boterenbrood, Hendrik; Boudreau, Joseph; Bouffard, Julian; Bouhova-Thacker, Evelina Vassileva; Boumediene, Djamel Eddine; Bourdarios, Claire; Bousson, Nicolas; Boutouil, Sara; Boveia, Antonio; Boyd, James; Boyko, Igor; Bracinik, Juraj; Brandt, Andrew; Brandt, Gerhard; Brandt, Oleg; Bratzler, Uwe; Brau, Benjamin; Brau, James; Braun, Helmut; Brazzale, Simone Federico; Brelier, Bertrand; Brendlinger, Kurt; Brennan, Amelia Jean; Brenner, Richard; Bressler, Shikma; Bristow, Kieran; Bristow, Timothy Michael; Britton, Dave; Brochu, Frederic; Brock, Ian; Brock, Raymond; Bromberg, Carl; Bronner, Johanna; Brooijmans, Gustaaf; Brooks, Timothy; Brooks, William; Brosamer, Jacquelyn; Brost, Elizabeth; Brown, Jonathan; Bruckman de Renstrom, Pawel; Bruncko, Dusan; Bruneliere, Renaud; Brunet, Sylvie; Bruni, Alessia; Bruni, Graziano; Bruschi, Marco; Bryngemark, Lene; Buanes, Trygve; Buat, Quentin; Bucci, Francesca; Buchholz, Peter; Buckingham, Ryan; Buckley, Andrew; Buda, Stelian Ioan; Budagov, Ioulian; Buehrer, Felix; Bugge, Lars; Bugge, Magnar Kopangen; Bulekov, Oleg; Bundock, Aaron Colin; Burckhart, Helfried; Burdin, Sergey; Burghgrave, Blake; Burke, Stephen; Burmeister, Ingo; Busato, Emmanuel; Büscher, Daniel; Büscher, Volker; Bussey, Peter; Buszello, Claus-Peter; Butler, Bart; Butler, John; Butt, Aatif Imtiaz; Buttar, Craig; Butterworth, Jonathan; Butti, Pierfrancesco; Buttinger, William; Buzatu, Adrian; Byszewski, Marcin; Cabrera Urbán, Susana; Caforio, Davide; Cakir, Orhan; Calafiura, Paolo; Calandri, Alessandro; Calderini, Giovanni; Calfayan, Philippe; Calkins, Robert; Caloba, Luiz; Calvet, David; Calvet, Samuel; Camacho Toro, Reina; Camarda, Stefano; Cameron, David; Caminada, Lea Michaela; Caminal Armadans, Roger; Campana, Simone; Campanelli, Mario; Campoverde, Angel; Canale, Vincenzo; Canepa, Anadi; Cano Bret, Marc; Cantero, Josu; Cantrill, Robert; Cao, Tingting; Capeans Garrido, Maria Del Mar; Caprini, Irinel; Caprini, Mihai; Capua, Marcella; Caputo, Regina; Cardarelli, Roberto; Carli, Tancredi; Carlino, Gianpaolo; Carminati, Leonardo; Caron, Sascha; Carquin, Edson; Carrillo-Montoya, German D; Carter, Janet; Carvalho, João; Casadei, Diego; Casado, Maria Pilar; Casolino, Mirkoantonio; Castaneda-Miranda, Elizabeth; Castelli, Angelantonio; Castillo Gimenez, Victoria; Castro, Nuno Filipe; Catastini, Pierluigi; Catinaccio, Andrea; Catmore, James; Cattai, Ariella; Cattani, Giordano; Caughron, Seth; Cavaliere, Viviana; Cavalli, Donatella; Cavalli-Sforza, Matteo; Cavasinni, Vincenzo; Ceradini, Filippo; Cerio, Benjamin; Cerny, Karel; Santiago Cerqueira, Augusto; Cerri, Alessandro; Cerrito, Lucio; Cerutti, Fabio; Cerv, Matevz; Cervelli, Alberto; Cetin, Serkant Ali; Chafaq, Aziz; Chakraborty, Dhiman; Chalupkova, Ina; Chang, Philip; Chapleau, Bertrand; Chapman, John Derek; Charfeddine, Driss; Charlton, Dave; Chau, Chav Chhiv; Chavez Barajas, Carlos Alberto; Cheatham, Susan; Chegwidden, Andrew; Chekanov, Sergei; Chekulaev, Sergey; Chelkov, Gueorgui; Chelstowska, Magda Anna; Chen, Chunhui; Chen, Hucheng; Chen, Karen; Chen, Liming; Chen, Shenjian; Chen, Xin; Chen, Ye; Chen, Yujiao; Cheng, Hok Chuen; Cheng, Yangyang; Cheplakov, Alexander; Cherkaoui El Moursli, Rajaa; Chernyatin, Valeriy; Cheu, Elliott; Chevalier, Laurent; Chiarella, Vitaliano; Chiefari, Giovanni; Childers, John Taylor; Chilingarov, Alexandre; Chiodini, Gabriele; Chisholm, Andrew; Chislett, Rebecca Thalatta; Chitan, Adrian; Chizhov, Mihail; Chouridou, Sofia; Chow, Bonnie Kar Bo; Chromek-Burckhart, Doris; Chu, Ming-Lee; Chudoba, Jiri; Chwastowski, Janusz; Chytka, Ladislav; Ciapetti, Guido; Ciftci, Abbas Kenan; Ciftci, Rena; Cinca, Diane; Cindro, Vladimir; Ciocio, Alessandra; Cirkovic, Predrag; Citron, Zvi Hirsh; Citterio, Mauro; Ciubancan, Mihai; Clark, Allan G; Clark, Philip James; Clarke, Robert; Cleland, Bill; Clemens, Jean-Claude; Clement, Christophe; Coadou, Yann; Cobal, Marina; Coccaro, Andrea; Cochran, James H; Coffey, Laurel; Cogan, Joshua Godfrey; Coggeshall, James; Cole, Brian; Cole, Stephen; Colijn, Auke-Pieter; Collot, Johann; Colombo, Tommaso; Colon, German; Compostella, Gabriele; Conde Muiño, Patricia; Coniavitis, Elias; Conidi, Maria Chiara; Connell, Simon Henry; Connelly, Ian; Consonni, Sofia Maria; Consorti, Valerio; Constantinescu, Serban; Conta, Claudio; Conti, Geraldine; Conventi, Francesco; Cooke, Mark; Cooper, Ben; Cooper-Sarkar, Amanda; Cooper-Smith, Neil; Copic, Katherine; Cornelissen, Thijs; Corradi, Massimo; Corriveau, Francois; Corso-Radu, Alina; Cortes-Gonzalez, Arely; Cortiana, Giorgio; Costa, Giuseppe; Costa, María José; Costanzo, Davide; Côté, David; Cottin, Giovanna; Cowan, Glen; Cox, Brian; Cranmer, Kyle; Cree, Graham; Crépé-Renaudin, Sabine; Crescioli, Francesco; Cribbs, Wayne Allen; Crispin Ortuzar, Mireia; Cristinziani, Markus; Croft, Vince; Crosetti, Giovanni; Cuciuc, Constantin-Mihai; Cuhadar Donszelmann, Tulay; Cummings, Jane; Curatolo, Maria; Cuthbert, Cameron; Czirr, Hendrik; Czodrowski, Patrick; Czyczula, Zofia; D'Auria, Saverio; D'Onofrio, Monica; Da Cunha Sargedas De Sousa, Mario Jose; Da Via, Cinzia; Dabrowski, Wladyslaw; Dafinca, Alexandru; Dai, Tiesheng; Dale, Orjan; Dallaire, Frederick; Dallapiccola, Carlo; Dam, Mogens; Daniells, Andrew Christopher; Dano Hoffmann, Maria; Dao, Valerio; Darbo, Giovanni; Darmora, Smita; Dassoulas, James; Dattagupta, Aparajita; Davey, Will; David, Claire; Davidek, Tomas; Davies, Eleanor; Davies, Merlin; Davignon, Olivier; Davison, Adam; Davison, Peter; Davygora, Yuriy; Dawe, Edmund; Dawson, Ian; Daya-Ishmukhametova, Rozmin; De, Kaushik; de Asmundis, Riccardo; De Castro, Stefano; De Cecco, Sandro; De Groot, Nicolo; de Jong, Paul; De la Torre, Hector; De Lorenzi, Francesco; De Nooij, Lucie; De Pedis, Daniele; De Salvo, Alessandro; De Sanctis, Umberto; De Santo, Antonella; De Vivie De Regie, Jean-Baptiste; Dearnaley, William James; Debbe, Ramiro; Debenedetti, Chiara; Dechenaux, Benjamin; Dedovich, Dmitri; Deigaard, Ingrid; Del Peso, Jose; Del Prete, Tarcisio; Deliot, Frederic; Delitzsch, Chris Malena; Deliyergiyev, Maksym; Dell'Acqua, Andrea; Dell'Asta, Lidia; Dell'Orso, Mauro; Della Pietra, Massimo; della Volpe, Domenico; Delmastro, Marco; Delsart, Pierre-Antoine; Deluca, Carolina; Demers, Sarah; Demichev, Mikhail; Demilly, Aurelien; Denisov, Sergey; Derendarz, Dominik; Derkaoui, Jamal Eddine; Derue, Frederic; Dervan, Paul; Desch, Klaus Kurt; Deterre, Cecile; Deviveiros, Pier-Olivier; Dewhurst, Alastair; Dhaliwal, Saminder; Di Ciaccio, Anna; Di Ciaccio, Lucia; Di Domenico, Antonio; Di Donato, Camilla; Di Girolamo, Alessandro; Di Girolamo, Beniamino; Di Mattia, Alessandro; Di Micco, Biagio; Di Nardo, Roberto; Di Simone, Andrea; Di Sipio, Riccardo; Di Valentino, David; Dias, Flavia; Diaz, Marco Aurelio; Diehl, Edward; Dietrich, Janet; Dietzsch, Thorsten; Diglio, Sara; Dimitrievska, Aleksandra; Dingfelder, Jochen; Dionisi, Carlo; Dita, Petre; Dita, Sanda; Dittus, Fridolin; Djama, Fares; Djobava, Tamar; Barros do Vale, Maria Aline; Do Valle Wemans, André; Doan, Thi Kieu Oanh; Dobos, Daniel; Doglioni, Caterina; Doherty, Tom; Dohmae, Takeshi; Dolejsi, Jiri; Dolezal, Zdenek; Dolgoshein, Boris; Donadelli, Marisilvia; Donati, Simone; Dondero, Paolo; Donini, Julien; Dopke, Jens; Doria, Alessandra; Dova, Maria-Teresa; Doyle, Tony; Dris, Manolis; Dubbert, Jörg; Dube, Sourabh; Dubreuil, Emmanuelle; Duchovni, Ehud; Duckeck, Guenter; Ducu, Otilia Anamaria; Duda, Dominik; Dudarev, Alexey; Dudziak, Fanny; Duflot, Laurent; Duguid, Liam; Dührssen, Michael; Dunford, Monica; Duran Yildiz, Hatice; Düren, Michael; Durglishvili, Archil; Dwuznik, Michal; Dyndal, Mateusz; Ebke, Johannes; Edson, William; Edwards, Nicholas Charles; Ehrenfeld, Wolfgang; Eifert, Till; Eigen, Gerald; Einsweiler, Kevin; Ekelof, Tord; El Kacimi, Mohamed; Ellert, Mattias; Elles, Sabine; Ellinghaus, Frank; Ellis, Nicolas; Elmsheuser, Johannes; Elsing, Markus; Emeliyanov, Dmitry; Enari, Yuji; Endner, Oliver Chris; Endo, Masaki; Engelmann, Roderich; Erdmann, Johannes; Ereditato, Antonio; Eriksson, Daniel; Ernis, Gunar; Ernst, Jesse; Ernst, Michael; Ernwein, Jean; Errede, Deborah; Errede, Steven; Ertel, Eugen; Escalier, Marc; Esch, Hendrik; Escobar, Carlos; Esposito, Bellisario; Etienvre, Anne-Isabelle; Etzion, Erez; Evans, Hal; Ezhilov, Alexey; Fabbri, Laura; Facini, Gabriel; Fakhrutdinov, Rinat; Falciano, Speranza; Falla, Rebecca Jane; Faltova, Jana; Fang, Yaquan; Fanti, Marcello; Farbin, Amir; Farilla, Addolorata; Farooque, Trisha; Farrell, Steven; Farrington, Sinead; Farthouat, Philippe; Fassi, Farida; Fassnacht, Patrick; Fassouliotis, Dimitrios; Favareto, Andrea; Fayard, Louis; Federic, Pavol; Fedin, Oleg; Fedorko, Wojciech; Fehling-Kaschek, Mirjam; Feigl, Simon; Feligioni, Lorenzo; Feng, Cunfeng; Feng, Eric; Feng, Haolu; Fenyuk, Alexander; Fernandez Perez, Sonia; Ferrag, Samir; Ferrando, James; Ferrari, Arnaud; Ferrari, Pamela; Ferrari, Roberto; Ferreira de Lima, Danilo Enoque; Ferrer, Antonio; Ferrere, Didier; Ferretti, Claudio; Ferretto Parodi, Andrea; Fiascaris, Maria; Fiedler, Frank; Filipčič, Andrej; Filipuzzi, Marco; Filthaut, Frank; Fincke-Keeler, Margret; Finelli, Kevin Daniel; Fiolhais, Miguel; Fiorini, Luca; Firan, Ana; Fischer, Adam; Fischer, Julia; Fisher, Wade Cameron; Fitzgerald, Eric Andrew; Flechl, Martin; Fleck, Ivor; Fleischmann, Philipp; Fleischmann, Sebastian; Fletcher, Gareth Thomas; Fletcher, Gregory; Flick, Tobias; Floderus, Anders; Flores Castillo, Luis; Florez Bustos, Andres Carlos; Flowerdew, Michael; Formica, Andrea; Forti, Alessandra; Fortin, Dominique; Fournier, Daniel; Fox, Harald; Fracchia, Silvia; Francavilla, Paolo; Franchini, Matteo; Franchino, Silvia; Francis, David; Franconi, Laura; Franklin, Melissa; Franz, Sebastien; Fraternali, Marco; French, Sky; Friedrich, Conrad; Friedrich, Felix; Froidevaux, Daniel; Frost, James; Fukunaga, Chikara; Fullana Torregrosa, Esteban; Fulsom, Bryan Gregory; Fuster, Juan; Gabaldon, Carolina; Gabizon, Ofir; Gabrielli, Alessandro; Gabrielli, Andrea; Gadatsch, Stefan; Gadomski, Szymon; Gagliardi, Guido; Gagnon, Pauline; Galea, Cristina; Galhardo, Bruno; Gallas, Elizabeth; Gallo, Valentina Santina; Gallop, Bruce; Gallus, Petr; Galster, Gorm Aske Gram Krohn; Gan, KK; Gao, Jun; Gao, Yongsheng; Garay Walls, Francisca; Garberson, Ford; García, Carmen; García Navarro, José Enrique; Garcia-Sciveres, Maurice; Gardner, Robert; Garelli, Nicoletta; Garonne, Vincent; Gatti, Claudio; Gaudio, Gabriella; Gaur, Bakul; Gauthier, Lea; Gauzzi, Paolo; Gavrilenko, Igor; Gay, Colin; Gaycken, Goetz; Gazis, Evangelos; Ge, Peng; Gecse, Zoltan; Gee, Norman; Geerts, Daniël Alphonsus Adrianus; Geich-Gimbel, Christoph; Gellerstedt, Karl; Gemme, Claudia; Gemmell, Alistair; Genest, Marie-Hélène; Gentile, Simonetta; George, Matthias; George, Simon; Gerbaudo, Davide; Gershon, Avi; Ghazlane, Hamid; Ghodbane, Nabil; Giacobbe, Benedetto; Giagu, Stefano; Giangiobbe, Vincent; Giannetti, Paola; Gianotti, Fabiola; Gibbard, Bruce; Gibson, Stephen; Gilchriese, Murdock; Gillam, Thomas; Gillberg, Dag; Gilles, Geoffrey; Gingrich, Douglas; Giokaris, Nikos; Giordani, MarioPaolo; Giordano, Raffaele; Giorgi, Filippo Maria; Giorgi, Francesco Michelangelo; Giraud, Pierre-Francois; Giugni, Danilo; Giuliani, Claudia; Giulini, Maddalena; Gjelsten, Børge Kile; Gkaitatzis, Stamatios; Gkialas, Ioannis; Gladilin, Leonid; Glasman, Claudia; Glatzer, Julian; Glaysher, Paul; Glazov, Alexandre; Glonti, George; Goblirsch-Kolb, Maximilian; Goddard, Jack Robert; Godfrey, Jennifer; Godlewski, Jan; Goeringer, Christian; Goldfarb, Steven; Golling, Tobias; Golubkov, Dmitry; Gomes, Agostinho; Gomez Fajardo, Luz Stella; Gonçalo, Ricardo; Goncalves Pinto Firmino Da Costa, Joao; Gonella, Laura; González de la Hoz, Santiago; Gonzalez Parra, Garoe; Gonzalez-Sevilla, Sergio; Goossens, Luc; Gorbounov, Petr Andreevich; Gordon, Howard; Gorelov, Igor; Gorini, Benedetto; Gorini, Edoardo; Gorišek, Andrej; Gornicki, Edward; Goshaw, Alfred; Gössling, Claus; Gostkin, Mikhail Ivanovitch; Gouighri, Mohamed; Goujdami, Driss; Goulette, Marc Phillippe; Goussiou, Anna; Goy, Corinne; Gozpinar, Serdar; Grabas, Herve Marie Xavier; Graber, Lars; Grabowska-Bold, Iwona; Grafström, Per; Grahn, Karl-Johan; Gramling, Johanna; Gramstad, Eirik; Grancagnolo, Sergio; Grassi, Valerio; Gratchev, Vadim; Gray, Heather; Graziani, Enrico; Grebenyuk, Oleg; Greenwood, Zeno Dixon; Gregersen, Kristian; Gregor, Ingrid-Maria; Grenier, Philippe; Griffiths, Justin; Grillo, Alexander; Grimm, Kathryn; Grinstein, Sebastian; Gris, Philippe Luc Yves; Grishkevich, Yaroslav; Grivaz, Jean-Francois; Grohs, Johannes Philipp; Grohsjean, Alexander; Gross, Eilam; Grosse-Knetter, Joern; Grossi, Giulio Cornelio; Groth-Jensen, Jacob; Grout, Zara Jane; Guan, Liang; Guescini, Francesco; Guest, Daniel; Gueta, Orel; Guicheney, Christophe; Guido, Elisa; Guillemin, Thibault; Guindon, Stefan; Gul, Umar; Gumpert, Christian; Gunther, Jaroslav; Guo, Jun; Gupta, Shaun; Gutierrez, Phillip; Gutierrez Ortiz, Nicolas Gilberto; Gutschow, Christian; Guttman, Nir; Guyot, Claude; Gwenlan, Claire; Gwilliam, Carl; Haas, Andy; Haber, Carl; Hadavand, Haleh Khani; Haddad, Nacim; Haefner, Petra; Hageböck, Stephan; Hajduk, Zbigniew; Hakobyan, Hrachya; Haleem, Mahsana; Hall, David; Halladjian, Garabed; Hamacher, Klaus; Hamal, Petr; Hamano, Kenji; Hamer, Matthias; Hamilton, Andrew; Hamilton, Samuel; Hamity, Guillermo Nicolas; Hamnett, Phillip George; Han, Liang; Hanagaki, Kazunori; Hanawa, Keita; Hance, Michael; Hanke, Paul; Hanna, Remie; Hansen, Jørgen Beck; Hansen, Jorn Dines; Hansen, Peter Henrik; Hara, Kazuhiko; Hard, Andrew; Harenberg, Torsten; Hariri, Faten; Harkusha, Siarhei; Harper, Devin; Harrington, Robert; Harris, Orin; Harrison, Paul Fraser; Hartjes, Fred; Hasegawa, Makoto; Hasegawa, Satoshi; Hasegawa, Yoji; Hasib, A; Hassani, Samira; Haug, Sigve; Hauschild, Michael; Hauser, Reiner; Havranek, Miroslav; Hawkes, Christopher; Hawkings, Richard John; Hawkins, Anthony David; Hayashi, Takayasu; Hayden, Daniel; Hays, Chris; Hayward, Helen; Haywood, Stephen; Head, Simon; Heck, Tobias; Hedberg, Vincent; Heelan, Louise; Heim, Sarah; Heim, Timon; Heinemann, Beate; Heinrich, Lukas; Hejbal, Jiri; Helary, Louis; Heller, Claudio; Heller, Matthieu; Hellman, Sten; Hellmich, Dennis; Helsens, Clement; Henderson, James; Henderson, Robert; Heng, Yang; Hengler, Christopher; Henrichs, Anna; Henriques Correia, Ana Maria; Henrot-Versille, Sophie; Hensel, Carsten; Herbert, Geoffrey Henry; Hernández Jiménez, Yesenia; Herrberg-Schubert, Ruth; Herten, Gregor; Hertenberger, Ralf; Hervas, Luis; Hesketh, Gavin Grant; Hessey, Nigel; Hickling, Robert; Higón-Rodriguez, Emilio; Hill, Ewan; Hill, John; Hiller, Karl Heinz; Hillert, Sonja; Hillier, Stephen; Hinchliffe, Ian; Hines, Elizabeth; Hirose, Minoru; Hirschbuehl, Dominic; Hobbs, John; Hod, Noam; Hodgkinson, Mark; Hodgson, Paul; Hoecker, Andreas; Hoeferkamp, Martin; Hoenig, Friedrich; Hoffman, Julia; Hoffmann, Dirk; Hofmann, Julia Isabell; Hohlfeld, Marc; Holmes, Tova Ray; Hong, Tae Min; Hooft van Huysduynen, Loek; Horii, Yasuyuki; Hostachy, Jean-Yves; Hou, Suen; Hoummada, Abdeslam; Howard, Jacob; Howarth, James; Hrabovsky, Miroslav; Hristova, Ivana; Hrivnac, Julius; Hryn'ova, Tetiana; Hsu, Catherine; Hsu, Pai-hsien Jennifer; Hsu, Shih-Chieh; Hu, Diedi; Hu, Xueye; Huang, Yanping; Hubacek, Zdenek; Hubaut, Fabrice; Huegging, Fabian; Huffman, Todd Brian; Hughes, Emlyn; Hughes, Gareth; Huhtinen, Mika; Hülsing, Tobias Alexander; Hurwitz, Martina; Huseynov, Nazim; Huston, Joey; Huth, John; Iacobucci, Giuseppe; Iakovidis, Georgios; Ibragimov, Iskander; Iconomidou-Fayard, Lydia; Ideal, Emma; Iengo, Paolo; Igonkina, Olga; Iizawa, Tomoya; Ikegami, Yoichi; Ikematsu, Katsumasa; Ikeno, Masahiro; Ilchenko, Iurii; Iliadis, Dimitrios; Ilic, Nikolina; Inamaru, Yuki; Ince, Tayfun; Ioannou, Pavlos; Iodice, Mauro; Iordanidou, Kalliopi; Ippolito, Valerio; Irles Quiles, Adrian; Isaksson, Charlie; Ishino, Masaya; Ishitsuka, Masaki; Ishmukhametov, Renat; Issever, Cigdem; Istin, Serhat; Iturbe Ponce, Julia Mariana; Iuppa, Roberto; Ivarsson, Jenny; Iwanski, Wieslaw; Iwasaki, Hiroyuki; Izen, Joseph; Izzo, Vincenzo; Jackson, Brett; Jackson, Matthew; Jackson, Paul; Jaekel, Martin; Jain, Vivek; Jakobs, Karl; Jakobsen, Sune; Jakoubek, Tomas; Jakubek, Jan; Jamin, David Olivier; Jana, Dilip; Jansen, Eric; Jansen, Hendrik; Janssen, Jens; Janus, Michel; Jarlskog, Göran; Javadov, Namig; Javůrek, Tomáš; Jeanty, Laura; Jejelava, Juansher; Jeng, Geng-yuan; Jennens, David; Jenni, Peter; Jentzsch, Jennifer; Jeske, Carl; Jézéquel, Stéphane; Ji, Haoshuang; Jia, Jiangyong; Jiang, Yi; Jimenez Belenguer, Marcos; Jin, Shan; Jinaru, Adam; Jinnouchi, Osamu; Joergensen, Morten Dam; Johansson, Erik; Johansson, Per; Johns, Kenneth; Jon-And, Kerstin; Jones, Graham; Jones, Roger; Jones, Tim; Jongmanns, Jan; Jorge, Pedro; Joshi, Kiran Daniel; Jovicevic, Jelena; Ju, Xiangyang; Jung, Christian; Jungst, Ralph Markus; Jussel, Patrick; Juste Rozas, Aurelio; Kaci, Mohammed; Kaczmarska, Anna; Kado, Marumi; Kagan, Harris; Kagan, Michael; Kajomovitz, Enrique; Kalderon, Charles William; Kama, Sami; Kamenshchikov, Andrey; Kanaya, Naoko; Kaneda, Michiru; Kaneti, Steven; Kantserov, Vadim; Kanzaki, Junichi; Kaplan, Benjamin; Kapliy, Anton; Kar, Deepak; Karakostas, Konstantinos; Karastathis, Nikolaos; Karnevskiy, Mikhail; Karpov, Sergey; Karpova, Zoya; Karthik, Krishnaiyengar; Kartvelishvili, Vakhtang; Karyukhin, Andrey; Kashif, Lashkar; Kasieczka, Gregor; Kass, Richard; Kastanas, Alex; Kataoka, Yousuke; Katre, Akshay; Katzy, Judith; Kaushik, Venkatesh; Kawagoe, Kiyotomo; Kawamoto, Tatsuo; Kawamura, Gen; Kazama, Shingo; Kazanin, Vassili; Kazarinov, Makhail; Keeler, Richard; Kehoe, Robert; Keil, Markus; Keller, John; Kempster, Jacob Julian; Keoshkerian, Houry; Kepka, Oldrich; Kerševan, Borut Paul; Kersten, Susanne; Kessoku, Kohei; Keung, Justin; Khalil-zada, Farkhad; Khandanyan, Hovhannes; Khanov, Alexander; Khodinov, Alexander; Khomich, Andrei; Khoo, Teng Jian; Khoriauli, Gia; Khoroshilov, Andrey; Khovanskiy, Valery; Khramov, Evgeniy; Khubua, Jemal; Kim, Hee Yeun; Kim, Hyeon Jin; Kim, Shinhong; Kimura, Naoki; Kind, Oliver; King, Barry; King, Matthew; King, Robert Steven Beaufoy; King, Samuel Burton; Kirk, Julie; Kiryunin, Andrey; Kishimoto, Tomoe; Kisielewska, Danuta; Kiss, Florian; Kittelmann, Thomas; Kiuchi, Kenji; Kladiva, Eduard; Klein, Max; Klein, Uta; Kleinknecht, Konrad; Klimek, Pawel; Klimentov, Alexei; Klingenberg, Reiner; Klinger, Joel Alexander; Klioutchnikova, Tatiana; Klok, Peter; Kluge, Eike-Erik; Kluit, Peter; Kluth, Stefan; Kneringer, Emmerich; Knoops, Edith; Knue, Andrea; Kobayashi, Dai; Kobayashi, Tomio; Kobel, Michael; Kocian, Martin; Kodys, Peter; Koevesarki, Peter; Koffas, Thomas; Koffeman, Els; Kogan, Lucy Anne; Kohlmann, Simon; Kohout, Zdenek; Kohriki, Takashi; Koi, Tatsumi; Kolanoski, Hermann; Koletsou, Iro; Koll, James; Komar, Aston; Komori, Yuto; Kondo, Takahiko; Kondrashova, Nataliia; Köneke, Karsten; König, Adriaan; König, Sebastian; Kono, Takanori; Konoplich, Rostislav; Konstantinidis, Nikolaos; Kopeliansky, Revital; Koperny, Stefan; Köpke, Lutz; Kopp, Anna Katharina; Korcyl, Krzysztof; Kordas, Kostantinos; Korn, Andreas; Korol, Aleksandr; Korolkov, Ilya; Korolkova, Elena; Korotkov, Vladislav; Kortner, Oliver; Kortner, Sandra; Kostyukhin, Vadim; Kotov, Vladislav; Kotwal, Ashutosh; Kourkoumelis, Christine; Kouskoura, Vasiliki; Koutsman, Alex; Kowalewski, Robert Victor; Kowalski, Tadeusz; Kozanecki, Witold; Kozhin, Anatoly; Kral, Vlastimil; Kramarenko, Viktor; Kramberger, Gregor; Krasnopevtsev, Dimitriy; Krasny, Mieczyslaw Witold; Krasznahorkay, Attila; Kraus, Jana; Kravchenko, Anton; Kreiss, Sven; Kretz, Moritz; Kretzschmar, Jan; Kreutzfeldt, Kristof; Krieger, Peter; Kroeninger, Kevin; Kroha, Hubert; Kroll, Joe; Kroseberg, Juergen; Krstic, Jelena; Kruchonak, Uladzimir; Krüger, Hans; Kruker, Tobias; Krumnack, Nils; Krumshteyn, Zinovii; Kruse, Amanda; Kruse, Mark; Kruskal, Michael; Kubota, Takashi; Kuday, Sinan; Kuehn, Susanne; Kugel, Andreas; Kuhl, Andrew; Kuhl, Thorsten; Kukhtin, Victor; Kulchitsky, Yuri; Kuleshov, Sergey; Kuna, Marine; Kunkle, Joshua; Kupco, Alexander; Kurashige, Hisaya; Kurochkin, Yurii; Kurumida, Rie; Kus, Vlastimil; Kuwertz, Emma Sian; Kuze, Masahiro; Kvita, Jiri; La Rosa, Alessandro; La Rotonda, Laura; Lacasta, Carlos; Lacava, Francesco; Lacey, James; Lacker, Heiko; Lacour, Didier; Lacuesta, Vicente Ramón; Ladygin, Evgueni; Lafaye, Remi; Laforge, Bertrand; Lagouri, Theodota; Lai, Stanley; Laier, Heiko; Lambourne, Luke; Lammers, Sabine; Lampen, Caleb; Lampl, Walter; Lançon, Eric; Landgraf, Ulrich; Landon, Murrough; Lang, Valerie Susanne; Lankford, Andrew; Lanni, Francesco; Lantzsch, Kerstin; Laplace, Sandrine; Lapoire, Cecile; Laporte, Jean-Francois; Lari, Tommaso; Lassnig, Mario; Laurelli, Paolo; Lavrijsen, Wim; Law, Alexander; Laycock, Paul; Le Dortz, Olivier; Le Guirriec, Emmanuel; Le Menedeu, Eve; LeCompte, Thomas; Ledroit-Guillon, Fabienne Agnes Marie; Lee, Claire Alexandra; Lee, Hurng-Chun; Lee, Jason; Lee, Shih-Chang; Lee, Lawrence; Lefebvre, Guillaume; Lefebvre, Michel; Legger, Federica; Leggett, Charles; Lehan, Allan; Lehmacher, Marc; Lehmann Miotto, Giovanna; Lei, Xiaowen; Leight, William Axel; Leisos, Antonios; Leister, Andrew Gerard; Leite, Marco Aurelio Lisboa; Leitner, Rupert; Lellouch, Daniel; Lemmer, Boris; Leney, Katharine; Lenz, Tatjana; Lenzen, Georg; Lenzi, Bruno; Leone, Robert; Leone, Sandra; Leonhardt, Kathrin; Leonidopoulos, Christos; Leontsinis, Stefanos; Leroy, Claude; Lester, Christopher; Lester, Christopher Michael; Levchenko, Mikhail; Levêque, Jessica; Levin, Daniel; Levinson, Lorne; Levy, Mark; Lewis, Adrian; Lewis, George; Leyko, Agnieszka; Leyton, Michael; Li, Bing; Li, Bo; Li, Haifeng; Li, Ho Ling; Li, Lei; Li, Liang; Li, Shu; Li, Yichen; Liang, Zhijun; Liao, Hongbo; Liberti, Barbara; Lichard, Peter; Lie, Ki; Liebal, Jessica; Liebig, Wolfgang; Limbach, Christian; Limosani, Antonio; Lin, Simon; Lin, Tai-Hua; Linde, Frank; Lindquist, Brian Edward; Linnemann, James; Lipeles, Elliot; Lipniacka, Anna; Lisovyi, Mykhailo; Liss, Tony; Lissauer, David; Lister, Alison; Litke, Alan; Liu, Bo; Liu, Dong; Liu, Jianbei; Liu, Kun; Liu, Lulu; Liu, Miaoyuan; Liu, Minghui; Liu, Yanwen; Livan, Michele; Livermore, Sarah; Lleres, Annick; Llorente Merino, Javier; Lloyd, Stephen; Lo Sterzo, Francesco; Lobodzinska, Ewelina; Loch, Peter; Lockman, William; Loddenkoetter, Thomas; Loebinger, Fred; Loevschall-Jensen, Ask Emil; Loginov, Andrey; Lohse, Thomas; Lohwasser, Kristin; Lokajicek, Milos; Lombardo, Vincenzo Paolo; Long, Brian Alexander; Long, Jonathan; Long, Robin Eamonn; Lopes, Lourenco; Lopez Mateos, David; Lopez Paredes, Brais; Lopez Paz, Ivan; Lorenz, Jeanette; Lorenzo Martinez, Narei; Losada, Marta; Loscutoff, Peter; Lou, XinChou; Lounis, Abdenour; Love, Jeremy; Love, Peter; Lowe, Andrew; Lu, Feng; Lu, Nan; Lubatti, Henry; Luci, Claudio; Lucotte, Arnaud; Luehring, Frederick; Lukas, Wolfgang; Luminari, Lamberto; Lundberg, Olof; Lund-Jensen, Bengt; Lungwitz, Matthias; Lynn, David; Lysak, Roman; Lytken, Else; Ma, Hong; Ma, Lian Liang; Maccarrone, Giovanni; Macchiolo, Anna; Machado Miguens, Joana; Macina, Daniela; Madaffari, Daniele; Madar, Romain; Maddocks, Harvey Jonathan; Mader, Wolfgang; Madsen, Alexander; Maeno, Mayuko; Maeno, Tadashi; Magradze, Erekle; Mahboubi, Kambiz; Mahlstedt, Joern; Mahmoud, Sara; Maiani, Camilla; Maidantchik, Carmen; Maier, Andreas Alexander; Maio, Amélia; Majewski, Stephanie; Makida, Yasuhiro; Makovec, Nikola; Mal, Prolay; Malaescu, Bogdan; Malecki, Pawel; Maleev, Victor; Malek, Fairouz; Mallik, Usha; Malon, David; Malone, Caitlin; Maltezos, Stavros; Malyshev, Vladimir; Malyukov, Sergei; Mamuzic, Judita; Mandelli, Beatrice; Mandelli, Luciano; Mandić, Igor; Mandrysch, Rocco; Maneira, José; Manfredini, Alessandro; Manhaes de Andrade Filho, Luciano; Manjarres Ramos, Joany Andreina; Mann, Alexander; Manning, Peter; Manousakis-Katsikakis, Arkadios; Mansoulie, Bruno; Mantifel, Rodger; Mapelli, Livio; March, Luis; Marchand, Jean-Francois; Marchiori, Giovanni; Marcisovsky, Michal; Marino, Christopher; Marjanovic, Marija; Marques, Carlos; Marroquim, Fernando; Marsden, Stephen Philip; Marshall, Zach; Marti, Lukas Fritz; Marti-Garcia, Salvador; Martin, Brian; Martin, Brian Thomas; Martin, Tim; Martin, Victoria Jane; Martin dit Latour, Bertrand; Martinez, Homero; Martinez, Mario; Martin-Haugh, Stewart; Martyniuk, Alex; Marx, Marilyn; Marzano, Francesco; Marzin, Antoine; Masetti, Lucia; Mashimo, Tetsuro; Mashinistov, Ruslan; Masik, Jiri; Maslennikov, Alexey; Massa, Ignazio; Massa, Lorenzo; Massol, Nicolas; Mastrandrea, Paolo; Mastroberardino, Anna; Masubuchi, Tatsuya; Mättig, Peter; Mattmann, Johannes; Maurer, Julien; Maxfield, Stephen; Maximov, Dmitriy; Mazini, Rachid; Mazzaferro, Luca; Mc Goldrick, Garrin; Mc Kee, Shawn Patrick; McCarn, Allison; McCarthy, Robert; McCarthy, Tom; McCubbin, Norman; McFarlane, Kenneth; Mcfayden, Josh; Mchedlidze, Gvantsa; McMahon, Steve; McPherson, Robert; Meade, Andrew; Mechnich, Joerg; Medinnis, Michael; Meehan, Samuel; Mehlhase, Sascha; Mehta, Andrew; Meier, Karlheinz; Meineck, Christian; Meirose, Bernhard; Melachrinos, Constantinos; Mellado Garcia, Bruce Rafael; Meloni, Federico; Mengarelli, Alberto; Menke, Sven; Meoni, Evelin; Mercurio, Kevin Michael; Mergelmeyer, Sebastian; Meric, Nicolas; Mermod, Philippe; Merola, Leonardo; Meroni, Chiara; Merritt, Frank; Merritt, Hayes; Messina, Andrea; Metcalfe, Jessica; Mete, Alaettin Serhan; Meyer, Carsten; Meyer, Christopher; Meyer, Jean-Pierre; Meyer, Jochen; Middleton, Robin; Migas, Sylwia; Mijović, Liza; Mikenberg, Giora; Mikestikova, Marcela; Mikuž, Marko; Milic, Adriana; Miller, David; Mills, Corrinne; Milov, Alexander; Milstead, David; Milstein, Dmitry; Minaenko, Andrey; Minashvili, Irakli; Mincer, Allen; Mindur, Bartosz; Mineev, Mikhail; Ming, Yao; Mir, Lluisa-Maria; Mirabelli, Giovanni; Mitani, Takashi; Mitrevski, Jovan; Mitsou, Vasiliki A; Mitsui, Shingo; Miucci, Antonio; Miyagawa, Paul; Mjörnmark, Jan-Ulf; Moa, Torbjoern; Mochizuki, Kazuya; Mohapatra, Soumya; Mohr, Wolfgang; Molander, Simon; Moles-Valls, Regina; Mönig, Klaus; Monini, Caterina; Monk, James; Monnier, Emmanuel; Montejo Berlingen, Javier; Monticelli, Fernando; Monzani, Simone; Moore, Roger; Morange, Nicolas; Moreno, Deywis; Moreno Llácer, María; Morettini, Paolo; Morgenstern, Marcus; Morii, Masahiro; Moritz, Sebastian; Morley, Anthony Keith; Mornacchi, Giuseppe; Morris, John; Morvaj, Ljiljana; Moser, Hans-Guenther; Mosidze, Maia; Moss, Josh; Motohashi, Kazuki; Mount, Richard; Mountricha, Eleni; Mouraviev, Sergei; Moyse, Edward; Muanza, Steve; Mudd, Richard; Mueller, Felix; Mueller, James; Mueller, Klemens; Mueller, Thibaut; Mueller, Timo; Muenstermann, Daniel; Munwes, Yonathan; Murillo Quijada, Javier Alberto; Murray, Bill; Musheghyan, Haykuhi; Musto, Elisa; Myagkov, Alexey; Myska, Miroslav; Nackenhorst, Olaf; Nadal, Jordi; Nagai, Koichi; Nagai, Ryo; Nagai, Yoshikazu; Nagano, Kunihiro; Nagarkar, Advait; Nagasaka, Yasushi; Nagel, Martin; Nairz, Armin Michael; Nakahama, Yu; Nakamura, Koji; Nakamura, Tomoaki; Nakano, Itsuo; Namasivayam, Harisankar; Nanava, Gizo; Narayan, Rohin; Nattermann, Till; Naumann, Thomas; Navarro, Gabriela; Nayyar, Ruchika; Neal, Homer; Nechaeva, Polina; Neep, Thomas James; Nef, Pascal Daniel; Negri, Andrea; Negri, Guido; Negrini, Matteo; Nektarijevic, Snezana; Nelson, Andrew; Nelson, Timothy Knight; Nemecek, Stanislav; Nemethy, Peter; Nepomuceno, Andre Asevedo; Nessi, Marzio; Neubauer, Mark; Neumann, Manuel; Neves, Ricardo; Nevski, Pavel; Newman, Paul; Nguyen, Duong Hai; Nickerson, Richard; Nicolaidou, Rosy; Nicquevert, Bertrand; Nielsen, Jason; Nikiforou, Nikiforos; Nikiforov, Andriy; Nikolaenko, Vladimir; Nikolic-Audit, Irena; Nikolics, Katalin; Nikolopoulos, Konstantinos; Nilsson, Paul; Ninomiya, Yoichi; Nisati, Aleandro; Nisius, Richard; Nobe, Takuya; Nodulman, Lawrence; Nomachi, Masaharu; Nomidis, Ioannis; Norberg, Scarlet; Nordberg, Markus; Novgorodova, Olga; Nowak, Sebastian; Nozaki, Mitsuaki; Nozka, Libor; Ntekas, Konstantinos; Nunes Hanninger, Guilherme; Nunnemann, Thomas; Nurse, Emily; Nuti, Francesco; O'Brien, Brendan Joseph; O'grady, Fionnbarr; O'Neil, Dugan; O'Shea, Val; Oakham, Gerald; Oberlack, Horst; Obermann, Theresa; Ocariz, Jose; Ochi, Atsuhiko; Ochoa, Ines; Oda, Susumu; Odaka, Shigeru; Ogren, Harold; Oh, Alexander; Oh, Seog; Ohm, Christian; Ohman, Henrik; Okamura, Wataru; Okawa, Hideki; Okumura, Yasuyuki; Okuyama, Toyonobu; Olariu, Albert; Olchevski, Alexander; Olivares Pino, Sebastian Andres; Oliveira Damazio, Denis; Oliver Garcia, Elena; Olszewski, Andrzej; Olszowska, Jolanta; Onofre, António; Onyisi, Peter; Oram, Christopher; Oreglia, Mark; Oren, Yona; Orestano, Domizia; Orlando, Nicola; Oropeza Barrera, Cristina; Orr, Robert; Osculati, Bianca; Ospanov, Rustem; Otero y Garzon, Gustavo; Otono, Hidetoshi; Ouchrif, Mohamed; Ouellette, Eric; Ould-Saada, Farid; Ouraou, Ahmimed; Oussoren, Koen Pieter; Ouyang, Qun; Ovcharova, Ana; Owen, Mark; Ozcan, Veysi Erkcan; Ozturk, Nurcan; Pachal, Katherine; Pacheco Pages, Andres; Padilla Aranda, Cristobal; Pagáčová, Martina; Pagan Griso, Simone; Paganis, Efstathios; Pahl, Christoph; Paige, Frank; Pais, Preema; Pajchel, Katarina; Palacino, Gabriel; Palestini, Sandro; Palka, Marek; Pallin, Dominique; Palma, Alberto; Palmer, Jody; Pan, Yibin; Panagiotopoulou, Evgenia; Panduro Vazquez, William; Pani, Priscilla; Panikashvili, Natalia; Panitkin, Sergey; Pantea, Dan; Paolozzi, Lorenzo; Papadopoulou, Theodora; Papageorgiou, Konstantinos; Paramonov, Alexander; Paredes Hernandez, Daniela; Parker, Michael Andrew; Parodi, Fabrizio; Parsons, John; Parzefall, Ulrich; Pasqualucci, Enrico; Passaggio, Stefano; Passeri, Antonio; Pastore, Fernanda; Pastore, Francesca; Pásztor, Gabriella; Pataraia, Sophio; Patel, Nikhul; Pater, Joleen; Patricelli, Sergio; Pauly, Thilo; Pearce, James; Pedersen, Lars Egholm; Pedersen, Maiken; Pedraza Lopez, Sebastian; Pedro, Rute; Peleganchuk, Sergey; Pelikan, Daniel; Peng, Haiping; Penning, Bjoern; Penwell, John; Perepelitsa, Dennis; Perez Codina, Estel; Pérez García-Estañ, María Teresa; Perez Reale, Valeria; Perini, Laura; Pernegger, Heinz; Perrino, Roberto; Peschke, Richard; Peshekhonov, Vladimir; Peters, Krisztian; Peters, Yvonne; Petersen, Brian; Petersen, Troels; Petit, Elisabeth; Petridis, Andreas; Petridou, Chariclia; Petrolo, Emilio; Petrucci, Fabrizio; Pettersson, Nora Emilia; Pezoa, Raquel; Phillips, Peter William; Piacquadio, Giacinto; Pianori, Elisabetta; Picazio, Attilio; Piccaro, Elisa; Piccinini, Maurizio; Piegaia, Ricardo; Pignotti, David; Pilcher, James; Pilkington, Andrew; Pina, João Antonio; Pinamonti, Michele; Pinder, Alex; Pinfold, James; Pingel, Almut; Pinto, Belmiro; Pires, Sylvestre; Pitt, Michael; Pizio, Caterina; Plazak, Lukas; Pleier, Marc-Andre; Pleskot, Vojtech; Plotnikova, Elena; Plucinski, Pawel; Poddar, Sahill; Podlyski, Fabrice; Poettgen, Ruth; Poggioli, Luc; Pohl, David-leon; Pohl, Martin; Polesello, Giacomo; Policicchio, Antonio; Polifka, Richard; Polini, Alessandro; Pollard, Christopher Samuel; Polychronakos, Venetios; Pommès, Kathy; Pontecorvo, Ludovico; Pope, Bernard; Popeneciu, Gabriel Alexandru; Popovic, Dragan; Poppleton, Alan; Portell Bueso, Xavier; Pospisil, Stanislav; Potamianos, Karolos; Potrap, Igor; Potter, Christina; Potter, Christopher; Poulard, Gilbert; Poveda, Joaquin; Pozdnyakov, Valery; Pralavorio, Pascal; Pranko, Aliaksandr; Prasad, Srivas; Pravahan, Rishiraj; Prell, Soeren; Price, Darren; Price, Joe; Price, Lawrence; Prieur, Damien; Primavera, Margherita; Proissl, Manuel; Prokofiev, Kirill; Prokoshin, Fedor; Protopapadaki, Eftychia-sofia; Protopopescu, Serban; Proudfoot, James; Przybycien, Mariusz; Przysiezniak, Helenka; Ptacek, Elizabeth; Puddu, Daniele; Pueschel, Elisa; Puldon, David; Purohit, Milind; Puzo, Patrick; Qian, Jianming; Qin, Gang; Qin, Yang; Quadt, Arnulf; Quarrie, David; Quayle, William; Queitsch-Maitland, Michaela; Quilty, Donnchadha; Qureshi, Anum; Radeka, Veljko; Radescu, Voica; Radhakrishnan, Sooraj Krishnan; Radloff, Peter; Rados, Pere; Ragusa, Francesco; Rahal, Ghita; Rajagopalan, Srinivasan; Rammensee, Michael; Randle-Conde, Aidan Sean; Rangel-Smith, Camila; Rao, Kanury; Rauscher, Felix; Rave, Tobias Christian; Ravenscroft, Thomas; Raymond, Michel; Read, Alexander Lincoln; Readioff, Nathan Peter; Rebuzzi, Daniela; Redelbach, Andreas; Redlinger, George; Reece, Ryan; Reeves, Kendall; Rehnisch, Laura; Reisin, Hernan; Relich, Matthew; Rembser, Christoph; Ren, Huan; Ren, Zhongliang; Renaud, Adrien; Rescigno, Marco; Resconi, Silvia; Rezanova, Olga; Reznicek, Pavel; Rezvani, Reyhaneh; Richter, Robert; Ridel, Melissa; Rieck, Patrick; Rieger, Julia; Rijssenbeek, Michael; Rimoldi, Adele; Rinaldi, Lorenzo; Ritsch, Elmar; Riu, Imma; Rizatdinova, Flera; Rizvi, Eram; Robertson, Steven; Robichaud-Veronneau, Andree; Robinson, Dave; Robinson, James; Robson, Aidan; Roda, Chiara; Rodrigues, Luis; Roe, Shaun; Røhne, Ole; Rolli, Simona; Romaniouk, Anatoli; Romano, Marino; Romero Adam, Elena; Rompotis, Nikolaos; Ronzani, Manfredi; Roos, Lydia; Ros, Eduardo; Rosati, Stefano; Rosbach, Kilian; Rose, Matthew; Rose, Peyton; Rosendahl, Peter Lundgaard; Rosenthal, Oliver; Rossetti, Valerio; Rossi, Elvira; Rossi, Leonardo Paolo; Rosten, Rachel; Rotaru, Marina; Roth, Itamar; Rothberg, Joseph; Rousseau, David; Royon, Christophe; Rozanov, Alexandre; Rozen, Yoram; Ruan, Xifeng; Rubbo, Francesco; Rubinskiy, Igor; Rud, Viacheslav; Rudolph, Christian; Rudolph, Matthew Scott; Rühr, Frederik; Ruiz-Martinez, Aranzazu; Rurikova, Zuzana; Rusakovich, Nikolai; Ruschke, Alexander; Rutherfoord, John; Ruthmann, Nils; Ryabov, Yury; Rybar, Martin; Rybkin, Grigori; Ryder, Nick; Saavedra, Aldo; Sacerdoti, Sabrina; Saddique, Asif; Sadeh, Iftach; Sadrozinski, Hartmut; Sadykov, Renat; Safai Tehrani, Francesco; Sakamoto, Hiroshi; Sakurai, Yuki; Salamanna, Giuseppe; Salamon, Andrea; Saleem, Muhammad; Salek, David; Sales De Bruin, Pedro Henrique; Salihagic, Denis; Salnikov, Andrei; Salt, José; Salvatore, Daniela; Salvatore, Pasquale Fabrizio; Salvucci, Antonio; Salzburger, Andreas; Sampsonidis, Dimitrios; Sanchez, Arturo; Sánchez, Javier; Sanchez Martinez, Victoria; Sandaker, Heidi; Sandbach, Ruth Laura; Sander, Heinz Georg; Sanders, Michiel; Sandhoff, Marisa; Sandoval, Tanya; Sandoval, Carlos; Sandstroem, Rikard; Sankey, Dave; Sansoni, Andrea; Santoni, Claudio; Santonico, Rinaldo; Santos, Helena; Santoyo Castillo, Itzebelt; Sapp, Kevin; Sapronov, Andrey; Saraiva, João; Sarrazin, Bjorn; Sartisohn, Georg; Sasaki, Osamu; Sasaki, Yuichi; Sauvage, Gilles; Sauvan, Emmanuel; Savard, Pierre; Savu, Dan Octavian; Sawyer, Craig; Sawyer, Lee; Saxon, David; Saxon, James; Sbarra, Carla; Sbrizzi, Antonio; Scanlon, Tim; Scannicchio, Diana; Scarcella, Mark; Scarfone, Valerio; Schaarschmidt, Jana; Schacht, Peter; Schaefer, Douglas; Schaefer, Ralph; Schaepe, Steffen; Schaetzel, Sebastian; Schäfer, Uli; Schaffer, Arthur; Schaile, Dorothee; Schamberger, R~Dean; Scharf, Veit; Schegelsky, Valery; Scheirich, Daniel; Schernau, Michael; Scherzer, Max; Schiavi, Carlo; Schieck, Jochen; Schillo, Christian; Schioppa, Marco; Schlenker, Stefan; Schmidt, Evelyn; Schmieden, Kristof; Schmitt, Christian; Schmitt, Sebastian; Schneider, Basil; Schnellbach, Yan Jie; Schnoor, Ulrike; Schoeffel, Laurent; Schoening, Andre; Schoenrock, Bradley Daniel; Schorlemmer, Andre Lukas; Schott, Matthias; Schouten, Doug; Schovancova, Jaroslava; Schramm, Steven; Schreyer, Manuel; Schroeder, Christian; Schuh, Natascha; Schultens, Martin Johannes; Schultz-Coulon, Hans-Christian; Schulz, Holger; Schumacher, Markus; Schumm, Bruce; Schune, Philippe; Schwanenberger, Christian; Schwartzman, Ariel; Schwegler, Philipp; Schwemling, Philippe; Schwienhorst, Reinhard; Schwindling, Jerome; Schwindt, Thomas; Schwoerer, Maud; Sciacca, Gianfranco; Scifo, Estelle; Sciolla, Gabriella; Scott, Bill; Scuri, Fabrizio; Scutti, Federico; Searcy, Jacob; Sedov, George; Sedykh, Evgeny; Seidel, Sally; Seiden, Abraham; Seifert, Frank; Seixas, José; Sekhniaidze, Givi; Sekula, Stephen; Selbach, Karoline Elfriede; Seliverstov, Dmitry; Sellers, Graham; Semprini-Cesari, Nicola; Serfon, Cedric; Serin, Laurent; Serkin, Leonid; Serre, Thomas; Seuster, Rolf; Severini, Horst; Sfiligoj, Tina; Sforza, Federico; Sfyrla, Anna; Shabalina, Elizaveta; Shamim, Mansoora; Shan, Lianyou; Shang, Ruo-yu; Shank, James; Shapiro, Marjorie; Shatalov, Pavel; Shaw, Kate; Shehu, Ciwake Yusufu; Sherwood, Peter; Shi, Liaoshan; Shimizu, Shima; Shimmin, Chase Owen; Shimojima, Makoto; Shiyakova, Mariya; Shmeleva, Alevtina; Shochet, Mel; Short, Daniel; Shrestha, Suyog; Shulga, Evgeny; Shupe, Michael; Shushkevich, Stanislav; Sicho, Petr; Sidiropoulou, Ourania; Sidorov, Dmitri; Sidoti, Antonio; Siegert, Frank; Sijacki, Djordje; Silva, José; Silver, Yiftah; Silverstein, Daniel; Silverstein, Samuel; Simak, Vladislav; Simard, Olivier; Simic, Ljiljana; Simion, Stefan; Simioni, Eduard; Simmons, Brinick; Simoniello, Rosa; Simonyan, Margar; Sinervo, Pekka; Sinev, Nikolai; Sipica, Valentin; Siragusa, Giovanni; Sircar, Anirvan; Sisakyan, Alexei; Sivoklokov, Serguei; Sjölin, Jörgen; Sjursen, Therese; Skottowe, Hugh Philip; Skovpen, Kirill; Skubic, Patrick; Slater, Mark; Slavicek, Tomas; Sliwa, Krzysztof; Smakhtin, Vladimir; Smart, Ben; Smestad, Lillian; Smirnov, Sergei; Smirnov, Yury; Smirnova, Lidia; Smirnova, Oxana; Smith, Kenway; Smizanska, Maria; Smolek, Karel; Snesarev, Andrei; Snidero, Giacomo; Snyder, Scott; Sobie, Randall; Socher, Felix; Soffer, Abner; Soh, Dart-yin; Solans, Carlos; Solar, Michael; Solc, Jaroslav; Soldatov, Evgeny; Soldevila, Urmila; Solodkov, Alexander; Soloshenko, Alexei; Solovyanov, Oleg; Solovyev, Victor; Sommer, Philip; Song, Hong Ye; Soni, Nitesh; Sood, Alexander; Sopczak, Andre; Sopko, Bruno; Sopko, Vit; Sorin, Veronica; Sosebee, Mark; Soualah, Rachik; Soueid, Paul; Soukharev, Andrey; South, David; Spagnolo, Stefania; Spanò, Francesco; Spearman, William Robert; Spettel, Fabian; Spighi, Roberto; Spigo, Giancarlo; Spiller, Laurence Anthony; Spousta, Martin; Spreitzer, Teresa; Spurlock, Barry; St Denis, Richard Dante; Staerz, Steffen; Stahlman, Jonathan; Stamen, Rainer; Stamm, Soren; Stanecka, Ewa; Stanek, Robert; Stanescu, Cristian; Stanescu-Bellu, Madalina; Stanitzki, Marcel Michael; Stapnes, Steinar; Starchenko, Evgeny; Stark, Jan; Staroba, Pavel; Starovoitov, Pavel; Staszewski, Rafal; Stavina, Pavel; Steinberg, Peter; Stelzer, Bernd; Stelzer, Harald Joerg; Stelzer-Chilton, Oliver; Stenzel, Hasko; Stern, Sebastian; Stewart, Graeme; Stillings, Jan Andre; Stockton, Mark; Stoebe, Michael; Stoicea, Gabriel; Stolte, Philipp; Stonjek, Stefan; Stradling, Alden; Straessner, Arno; Stramaglia, Maria Elena; Strandberg, Jonas; Strandberg, Sara; Strandlie, Are; Strauss, Emanuel; Strauss, Michael; Strizenec, Pavol; Ströhmer, Raimund; Strom, David; Stroynowski, Ryszard; Struebig, Antonia; Stucci, Stefania Antonia; Stugu, Bjarne; Styles, Nicholas Adam; Su, Dong; Su, Jun; Subramaniam, Rajivalochan; Succurro, Antonella; Sugaya, Yorihito; Suhr, Chad; Suk, Michal; Sulin, Vladimir; Sultansoy, Saleh; Sumida, Toshi; Sun, Siyuan; Sun, Xiaohu; Sundermann, Jan Erik; Suruliz, Kerim; Susinno, Giancarlo; Sutton, Mark; Suzuki, Yu; Svatos, Michal; Swedish, Stephen; Swiatlowski, Maximilian; Sykora, Ivan; Sykora, Tomas; Ta, Duc; Taccini, Cecilia; Tackmann, Kerstin; Taenzer, Joe; Taffard, Anyes; Tafirout, Reda; Taiblum, Nimrod; Takai, Helio; Takashima, Ryuichi; Takeda, Hiroshi; Takeshita, Tohru; Takubo, Yosuke; Talby, Mossadek; Talyshev, Alexey; Tam, Jason; Tan, Kong Guan; Tanaka, Junichi; Tanaka, Reisaburo; Tanaka, Satoshi; Tanaka, Shuji; Tanasijczuk, Andres Jorge; Tannenwald, Benjamin Bordy; Tannoury, Nancy; Tapprogge, Stefan; Tarem, Shlomit; Tarrade, Fabien; Tartarelli, Giuseppe Francesco; Tas, Petr; Tasevsky, Marek; Tashiro, Takuya; Tassi, Enrico; Tavares Delgado, Ademar; Tayalati, Yahya; Taylor, Frank; Taylor, Geoffrey; Taylor, Wendy; Teischinger, Florian Alfred; Teixeira Dias Castanheira, Matilde; Teixeira-Dias, Pedro; Temming, Kim Katrin; Ten Kate, Herman; Teng, Ping-Kun; Teoh, Jia Jian; Terada, Susumu; Terashi, Koji; Terron, Juan; Terzo, Stefano; Testa, Marianna; Teuscher, Richard; Therhaag, Jan; Theveneaux-Pelzer, Timothée; Thomas, Juergen; Thomas-Wilsker, Joshuha; Thompson, Emily; Thompson, Paul; Thompson, Peter; Thompson, Ray; Thompson, Stan; Thomsen, Lotte Ansgaard; Thomson, Evelyn; Thomson, Mark; Thong, Wai Meng; Thun, Rudolf; Tian, Feng; Tibbetts, Mark James; Tikhomirov, Vladimir; Tikhonov, Yury; Timoshenko, Sergey; Tiouchichine, Elodie; Tipton, Paul; Tisserant, Sylvain; Todorov, Theodore; Todorova-Nova, Sharka; Toggerson, Brokk; Tojo, Junji; Tokár, Stanislav; Tokushuku, Katsuo; Tollefson, Kirsten; Tomlinson, Lee; Tomoto, Makoto; Tompkins, Lauren; Toms, Konstantin; Topilin, Nikolai; Torrence, Eric; Torres, Heberth; Torró Pastor, Emma; Toth, Jozsef; Touchard, Francois; Tovey, Daniel; Tran, Huong Lan; Trefzger, Thomas; Tremblet, Louis; Tricoli, Alessandro; Trigger, Isabel Marian; Trincaz-Duvoid, Sophie; Tripiana, Martin; Trischuk, William; Trocmé, Benjamin; Troncon, Clara; Trottier-McDonald, Michel; Trovatelli, Monica; True, Patrick; Trzebinski, Maciej; Trzupek, Adam; Tsarouchas, Charilaos; Tseng, Jeffrey; Tsiareshka, Pavel; Tsionou, Dimitra; Tsipolitis, Georgios; Tsirintanis, Nikolaos; Tsiskaridze, Shota; Tsiskaridze, Vakhtang; Tskhadadze, Edisher; Tsukerman, Ilya; Tsulaia, Vakhtang; Tsuno, Soshi; Tsybychev, Dmitri; Tudorache, Alexandra; Tudorache, Valentina; Tuna, Alexander Naip; Tupputi, Salvatore; Turchikhin, Semen; Turecek, Daniel; Turk Cakir, Ilkay; Turra, Ruggero; Tuts, Michael; Tykhonov, Andrii; Tylmad, Maja; Tyndel, Mike; Uchida, Kirika; Ueda, Ikuo; Ueno, Ryuichi; Ughetto, Michael; Ugland, Maren; Uhlenbrock, Mathias; Ukegawa, Fumihiko; Unal, Guillaume; Undrus, Alexander; Unel, Gokhan; Ungaro, Francesca; Unno, Yoshinobu; Unverdorben, Christopher; Urbaniec, Dustin; Urquijo, Phillip; Usai, Giulio; Usanova, Anna; Vacavant, Laurent; Vacek, Vaclav; Vachon, Brigitte; Valencic, Nika; Valentinetti, Sara; Valero, Alberto; Valery, Loic; Valkar, Stefan; Valladolid Gallego, Eva; Vallecorsa, Sofia; Valls Ferrer, Juan Antonio; Van Den Wollenberg, Wouter; Van Der Deijl, Pieter; van der Geer, Rogier; van der Graaf, Harry; Van Der Leeuw, Robin; van der Ster, Daniel; van Eldik, Niels; van Gemmeren, Peter; Van Nieuwkoop, Jacobus; van Vulpen, Ivo; van Woerden, Marius Cornelis; Vanadia, Marco; Vandelli, Wainer; Vanguri, Rami; Vaniachine, Alexandre; Vankov, Peter; Vannucci, Francois; Vardanyan, Gagik; Vari, Riccardo; Varnes, Erich; Varol, Tulin; Varouchas, Dimitris; Vartapetian, Armen; Varvell, Kevin; Vazeille, Francois; Vazquez Schroeder, Tamara; Veatch, Jason; Veloso, Filipe; Veneziano, Stefano; Ventura, Andrea; Ventura, Daniel; Venturi, Manuela; Venturi, Nicola; Venturini, Alessio; Vercesi, Valerio; Verducci, Monica; Verkerke, Wouter; Vermeulen, Jos; Vest, Anja; Vetterli, Michel; Viazlo, Oleksandr; Vichou, Irene; Vickey, Trevor; Vickey Boeriu, Oana Elena; Viehhauser, Georg; Viel, Simon; Vigne, Ralph; Villa, Mauro; Villaplana Perez, Miguel; Vilucchi, Elisabetta; Vincter, Manuella; Vinogradov, Vladimir; Virzi, Joseph; Vivarelli, Iacopo; Vives Vaque, Francesc; Vlachos, Sotirios; Vladoiu, Dan; Vlasak, Michal; Vogel, Adrian; Vogel, Marcelo; Vokac, Petr; Volpi, Guido; Volpi, Matteo; von der Schmitt, Hans; von Radziewski, Holger; von Toerne, Eckhard; Vorobel, Vit; Vorobev, Konstantin; Vos, Marcel; Voss, Rudiger; Vossebeld, Joost; Vranjes, Nenad; Vranjes Milosavljevic, Marija; Vrba, Vaclav; Vreeswijk, Marcel; Vu Anh, Tuan; Vuillermet, Raphael; Vukotic, Ilija; Vykydal, Zdenek; Wagner, Peter; Wagner, Wolfgang; Wahlberg, Hernan; Wahrmund, Sebastian; Wakabayashi, Jun; Walder, James; Walker, Rodney; Walkowiak, Wolfgang; Wall, Richard; Waller, Peter; Walsh, Brian; Wang, Chao; Wang, Chiho; Wang, Fuquan; Wang, Haichen; Wang, Hulin; Wang, Jike; Wang, Jin; Wang, Kuhan; Wang, Rui; Wang, Song-Ming; Wang, Tan; Wang, Xiaoxiao; Wanotayaroj, Chaowaroj; Warburton, Andreas; Ward, Patricia; Wardrope, David Robert; Warsinsky, Markus; Washbrook, Andrew; Wasicki, Christoph; Watkins, Peter; Watson, Alan; Watson, Ian; Watson, Miriam; Watts, Gordon; Watts, Stephen; Waugh, Ben; Webb, Samuel; Weber, Michele; Weber, Stefan Wolf; Webster, Jordan S; Weidberg, Anthony; Weigell, Philipp; Weinert, Benjamin; Weingarten, Jens; Weiser, Christian; Weits, Hartger; Wells, Phillippa; Wenaus, Torre; Wendland, Dennis; Weng, Zhili; Wengler, Thorsten; Wenig, Siegfried; Wermes, Norbert; Werner, Matthias; Werner, Per; Wessels, Martin; Wetter, Jeffrey; Whalen, Kathleen; White, Andrew; White, Martin; White, Ryan; White, Sebastian; Whiteson, Daniel; Wicke, Daniel; Wickens, Fred; Wiedenmann, Werner; Wielers, Monika; Wienemann, Peter; Wiglesworth, Craig; Wiik-Fuchs, Liv Antje Mari; Wijeratne, Peter Alexander; Wildauer, Andreas; Wildt, Martin Andre; Wilkens, Henric George; Will, Jonas Zacharias; Williams, Hugh; Williams, Sarah; Willis, Christopher; Willocq, Stephane; Wilson, Alan; Wilson, John; Wingerter-Seez, Isabelle; Winklmeier, Frank; Winter, Benedict Tobias; Wittgen, Matthias; Wittig, Tobias; Wittkowski, Josephine; Wollstadt, Simon Jakob; Wolter, Marcin Wladyslaw; Wolters, Helmut; Wosiek, Barbara; Wotschack, Jorg; Woudstra, Martin; Wozniak, Krzysztof; Wright, Michael; Wu, Mengqing; Wu, Sau Lan; Wu, Xin; Wu, Yusheng; Wulf, Evan; Wyatt, Terry Richard; Wynne, Benjamin; Xella, Stefania; Xiao, Meng; Xu, Da; Xu, Lailin; Yabsley, Bruce; Yacoob, Sahal; Yakabe, Ryota; Yamada, Miho; Yamaguchi, Hiroshi; Yamaguchi, Yohei; Yamamoto, Akira; Yamamoto, Kyoko; Yamamoto, Shimpei; Yamamura, Taiki; Yamanaka, Takashi; Yamauchi, Katsuya; Yamazaki, Yuji; Yan, Zhen; Yang, Haijun; Yang, Hongtao; Yang, Un-Ki; Yang, Yi; Yanush, Serguei; Yao, Liwen; Yao, Weiming; Yasu, Yoshiji; Yatsenko, Elena; Yau Wong, Kaven Henry; Ye, Jingbo; Ye, Shuwei; Yeletskikh, Ivan; Yen, Andy L; Yildirim, Eda; Yilmaz, Metin; Yoosoofmiya, Reza; Yorita, Kohei; Yoshida, Rikutaro; Yoshihara, Keisuke; Young, Charles; Young, Christopher John; Youssef, Saul; Yu, David Ren-Hwa; Yu, Jaehoon; Yu, Jiaming; Yu, Jie; Yuan, Li; Yurkewicz, Adam; Yusuff, Imran; Zabinski, Bartlomiej; Zaidan, Remi; Zaitsev, Alexander; Zaman, Aungshuman; Zambito, Stefano; Zanello, Lucia; Zanzi, Daniele; Zeitnitz, Christian; Zeman, Martin; Zemla, Andrzej; Zengel, Keith; Zenin, Oleg; Ženiš, Tibor; Zerwas, Dirk; Zevi della Porta, Giovanni; Zhang, Dongliang; Zhang, Fangzhou; Zhang, Huaqiao; Zhang, Jinlong; Zhang, Lei; Zhang, Xueyao; Zhang, Zhiqing; Zhao, Zhengguo; Zhemchugov, Alexey; Zhong, Jiahang; Zhou, Bing; Zhou, Lei; Zhou, Ning; Zhu, Cheng Guang; Zhu, Hongbo; Zhu, Junjie; Zhu, Yingchun; Zhuang, Xuai; Zhukov, Konstantin; Zibell, Andre; Zieminska, Daria; Zimine, Nikolai; Zimmermann, Christoph; Zimmermann, Robert; Zimmermann, Simone; Zimmermann, Stephanie; Zinonos, Zinonas; Ziolkowski, Michael; Zobernig, Georg; Zoccoli, Antonio; zur Nedden, Martin; Zurzolo, Giovanni; Zutshi, Vishnu; Zwalinski, Lukasz

    2014-10-01

    This paper presents the electron and photon energy calibration achieved with the ATLAS detector using about 25 fb$^{-1}$ of LHC proton--proton collision data taken at centre-of-mass energies of $\\sqrt{s}$ = 7 and 8 TeV. The reconstruction of electron and photon energies is optimised using multivariate algorithms. The response of the calorimeter layers is equalised in data and simulation, and the longitudinal profile of the electromagnetic showers is exploited to estimate the passive material in front of the calorimeter and reoptimise the detector simulation. After all corrections, the $Z$ resonance is used to set the absolute energy scale. For electrons from $Z$ decays, the achieved calibration is typically accurate to 0.05% in most of the detector acceptance, rising to 0.2% in regions with large amounts of passive material. The remaining inaccuracy is less than 0.2-1% for electrons with a transverse energy of 10 GeV, and is on average 0.3% for photons. The detector resolution is determined with a relative in...

  7. Two-electron one-photon decay rates in doubly ionized atoms

    International Nuclear Information System (INIS)

    Baptista, G.B.

    1984-01-01

    The transion rate for the two-electron one-photon and one-electron one-photon decaying processes in atoms bearing initially two K-shell vacancies were evaluated for Ne up to Zr. The two-electron one-photon decay process is considered to be the result of the interaction between the jumping electrons and their interaction with the radiation field. The calculation is performed in second order perturbation theory and the many particle states are constructed from single particle solutions. The present approach allows one to discuss several aspects of the decaying process. The results obtained for the branching ratio between the two processes reproduces reasonably well available experimental data and show an almost linear dependence on the second power of the atomic number. A comparison with other theoretical predictions is also presented for the two decaying processes and the strong dependence of the branching ratio on the initial configuration of the decaying atom is pointed out. (Author) [pt

  8. Evaluation of the Accuracy of Polymer Gels for Determining Electron Dose Distributions in the Presence of Small Heterogeneities.

    Science.gov (United States)

    Asl, R Ghahraman; Nedaie, H A; Banaee, N

    2017-12-01

    The aim of this study is to evaluate the application and accuracy of polymer gels for determining electron dose distributions in the presence of small heterogeneities made of bone and air. Different cylindrical phantoms containing MAGIC (Methacrylic and Ascorbic acid in Gelatin Initiated by Copper) normoxic polymer gel were used under the slab phantoms during irradiation. MR images of the irradiated gel phantoms were obtained to determine their R2 (spin-spin) relaxation maps for conversion to absorbed dose. One- and 2-dimensional lateral dose profiles were acquired at depths of 1 and 4 cm for 8 and 15 MeV electron beams. The results were compared with the doses measured by a diode detector at the same positions. In addition, the dose distribution in the axial orientation was measured by the gel dosimeter. The slope and intercept for the R2 versus dose curve were 0.509 ± 0.002 Gy s and 4.581 ± 0.005 s, respectively. No significant variation in dose-R2 response was seen for the two electron energies within the applied dose ranges. The mean dose difference between the measured gel dose profiles was smaller than 3% compared to those measured by the diode detector. These results provide further demonstration that electron dose distributions are significantly altered in the presence of tissue inhomogeneities such as bone and air cavity and that MAGIC gel is a useful tool for 3-dimensional dose visualization and qualitative assessment of tissue inhomogeneity effects in electron beam dosimetry.

  9. Effective atomic numbers, electron densities and kinetic energy released in matter of vitamins for photon interaction

    Science.gov (United States)

    Shantappa, A.; Hanagodimath, S. M.

    2014-01-01

    Effective atomic numbers, electron densities of some vitamins (Retinol, Riboflavin, Niacin, Biotin, Folic acid, Cobalamin, Phylloquinone and Flavonoids) composed of C, H, O, N, Co, P and S have been calculated for total and partial photon interactions by the direct method for energy range 1 keV-100 GeV by using WinXCOM and kinetic energy released in matter (Kerma) relative to air is calculated in energy range of 1 keV-20 MeV. Change in effective atomic number and electron density with energy is calculated for all photon interactions. Variation of photon mass attenuation coefficients with energy are shown graphically only for total photon interaction. It is observed that change in mass attenuation coefficient with composition of different chemicals is very large below 100 keV and moderate between 100 keV and 10 MeV and negligible above 10 MeV. Behaviour of vitamins is almost indistinguishable except biotin and cobalamin because of large range of atomic numbers from 1(H) to 16 (S) and 1(H) to 27(Co) respectively. K a value shows a peak due to the photoelectric effect around K-absorption edge of high- Z constituent of compound for biotin and cobalamin.

  10. Electron Correlations and Two-Photon States in Polycyclic Aromatic Hydrocarbon Molecules: A Peculiar Role of Geometry

    OpenAIRE

    Aryanpour, K.; Shukla, A.; Mazumdar, S.

    2013-01-01

    We present numerical studies of one- and two-photon excited states ordering in a number of polycyclic aromatic hydrocarbon molecules: coronene, hexa-peri-hexabenzocoronene and circumcoronene, all possessing $D_{6h}$ point group symmetry versus ovalene with $D_{2h}$ symmetry, within the Pariser-Parr-Pople model of interacting $\\pi$-electrons. The calculated energies of the two-photon states as well as their relative two-photon absorption cross-sections within the interacting model are qualitat...

  11. First results from electron-photon damage equivalence studies on a generic ethylene-propylene rubber

    International Nuclear Information System (INIS)

    Buckalew, W.H.

    1986-04-01

    As part of a simulator adequacy assessment program, the relative effectiveness of electrons and photons to produce damage in a generic ethylene propylene rubber (EPR) has been investigated. The investigation was limited in extent in that a single EPR material, in three thickness, was exposed to Cobalt-60 photons and three electron beam energies. Basing material damage on changes in the EPR mechanical properties elongation and tensile strength, we observed that EPR damage was a smoothly varying function of absorbed energy and independent of irradiating particle type. EPR damage tracked equally well as a function of both incident particle energy and material front surface dose. Based on these preliminary data, we tentatively concluded that a correlation between particle, particle energy, and material damage (as measured by changes in material elongation and/or tensile strength) has been demonstrated. 14 figs

  12. Dose conversion coefficients for high-energy photons, electrons, neutrons and protons

    CERN Document Server

    Sakamoto, Y; Sato, O; Tanaka, S I; Tsuda, S; Yamaguchi, Y; Yoshizawa, N

    2003-01-01

    In the International Commission on Radiological Protection (ICRP) 1990 Recommendations, radiation weighting factors were introduced in the place of quality factors, the tissue weighting factors were revised, and effective doses and equivalent doses of each tissues and organs were defined as the protection quantities. Dose conversion coefficients for photons, electrons and neutrons based on new ICRP recommendations were cited in the ICRP Publication 74, but the energy ranges of theses data were limited and there are no data for high energy radiations produced in accelerator facilities. For the purpose of designing the high intensity proton accelerator facilities at JAERI, the dose evaluation code system of high energy radiations based on the HERMES code was developed and the dose conversion coefficients of effective dose were evaluated for photons, neutrons and protons up to 10 GeV, and electrons up to 100 GeV. The dose conversion coefficients of effective dose equivalent were also evaluated using quality fact...

  13. Skeletal dosimetry in a voxel-based rat phantom for internal exposures to photons and electrons.

    Science.gov (United States)

    Xie, Tianwu; Han, Dao; Liu, Yang; Sun, Wenjuan; Liu, Qian

    2010-05-01

    The skeleton makes a significant contribution to the whole body absorbed dose evaluation of rats, since the bone marrow and bone surface in the skeleton express high radiosensitivity and are considered to be important dose-limiting tissues. The bone marrow can be categorized as red bone marrow (RBM) and yellow bone marrow (YBM). It is important to investigate the bone marrow in skeletal dosimetry. Cryosectional color images of the skeleton of a 156 g rat were segmented into mineral bone (including cortical bone and trabecular bone), RBM, and YBM. These three tissue types were identified at 40 different bone sites and integrated into a previously developed voxel-based rat computational phantom. Photon and electron skeletal absorbed fractions were then calculated using the MCNPX Monte Carlo code. Absorbed fraction (AF) and specific absorbed fraction (SAF) for mineral bone, RBM, and YBM at the 40 different bone sites were established for monoenergetic photon and electron sources placed in 18 organs and seven bone sites. Discrete photon energy was varied from 0.01 to 5.0 MeV in 21 discrete steps, while 21 discrete electron energies were studied, from 0.1 to 10.0 MeV. The trends and values found were consistent with the results of other researchers [M. G. Stabin, T. E. Peterson, G. E. Holburn, and M. A. Emmons, "Voxel-based mouse and rat models for internal dose calculations," J. Nucl. Med. 47, 655-659 (2006)]. S-factors for the radionuclides 169Er, 143Pr, 89Sr, 32P, and 90Y, located in 18 organs and seven bone sites for the skeleton, were calculated and are provided in detail. For internal dose calculations, the AF data reveal that the mineral bone in the rat skeletal system is responsible for significant attenuation of gamma rays, especially at low energies. The photon SAF curves of RBM show that, for photon energies greater than 0.6 MeV, there is an increase in secondary photons emitted from the mineral bone as photon energy increases. The SAF values calculated in

  14. Skeletal dosimetry in a voxel-based rat phantom for internal exposures to photons and electrons

    Energy Technology Data Exchange (ETDEWEB)

    Xie Tianwu; Han Dao; Liu Yang; Sun Wenjuan; Liu Qian [Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074 (China)

    2010-05-15

    Purpose: The skeleton makes a significant contribution to the whole body absorbed dose evaluation of rats, since the bone marrow and bone surface in the skeleton express high radiosensitivity and are considered to be important dose-limiting tissues. The bone marrow can be categorized as red bone marrow (RBM) and yellow bone marrow (YBM). It is important to investigate the bone marrow in skeletal dosimetry. Methods: Cryosectional color images of the skeleton of a 156 g rat were segmented into mineral bone (including cortical bone and trabecular bone), RBM, and YBM. These three tissue types were identified at 40 different bone sites and integrated into a previously developed voxel-based rat computational phantom. Photon and electron skeletal absorbed fractions were then calculated using the MCNPX Monte Carlo code. Results: Absorbed fraction (AF) and specific absorbed fraction (SAF) for mineral bone, RBM, and YBM at the 40 different bone sites were established for monoenergetic photon and electron sources placed in 18 organs and seven bone sites. Discrete photon energy was varied from 0.01 to 5.0 MeV in 21 discrete steps, while 21 discrete electron energies were studied, from 0.1 to 10.0 MeV. The trends and values found were consistent with the results of other researchers [M. G. Stabin, T. E. Peterson, G. E. Holburn, and M. A. Emmons, ''Voxel-based mouse and rat models for internal dose calculations,'' J. Nucl. Med. 47, 655-659 (2006)]. S-factors for the radionuclides {sup 169}Er, {sup 143}Pr, {sup 89}Sr, {sup 32}P, and {sup 90}Y, located in 18 organs and seven bone sites for the skeleton, were calculated and are provided in detail. Conclusions: For internal dose calculations, the AF data reveal that the mineral bone in the rat skeletal system is responsible for significant attenuation of gamma rays, especially at low energies. The photon SAF curves of RBM show that, for photon energies greater than 0.6 MeV, there is an increase in secondary

  15. Handbook of theoretical atomic physics data for photon absorption, electron scattering, and vacancies decay

    CERN Document Server

    Amusia, Miron Ya; Yarzhemsky, Victor

    2012-01-01

    The aim of this book is to present highly accurate and extensive theoretical Atomic data and to give a survey of selected calculational methods for atomic physics, used to obtain these data. The book presents the results of calculations of cross sections and probabilities of a broad variety of atomic processes with participation of photons and electrons, namely on photoabsorption, electron scattering and accompanying effects. Included are data for photoabsorption and electron scattering cross-sections and probabilities of vacancy decay formed for a large number of atoms and ions. Attention is also given to photoionization and vacancy decay in endohedrals and to positron-atom scattering. The book is richly illustrated. The methods used are one-electron Hartree-Fock and the technique of Feynman diagrams that permits to include many-electron correlations. This is done in the frames of the Random Phase approximation with exchange and the many-body perturbation theory. Newly obtained and previously collected atomi...

  16. Delivery of modulated electron beams with conventional photon multi-leaf collimators

    International Nuclear Information System (INIS)

    Klein, Eric E; Mamalui-Hunter, Maria; Low, Daniel A

    2009-01-01

    Electron beam radiotherapy is an accepted method to treat shallow tumors. However, modulation of electrons to customize dose distributions has not readily been achieved. Studies of bolus and tertiary collimation systems have been met with limitations. We pursue the use of photon multi-leaf collimators (MLC) for modulated electron radiotherapy (MERT) to achieve customized distributions for potential clinical use. As commercial planning systems do not support the use of MLC with electrons, planning was conducted using Monte Carlo calculations. Segmented and dynamic modulated delivery of multiple electron segments was configured, calculated and delivered for validation. Delivery of electrons with segmented or dynamic leaf motion was conducted. A phantom possessing an idealized stepped target was planned and optimized with subsequent validation by measurements. Finally, clinical treatment plans were conducted for post-mastectomy and cutaneous lymphoma of the scalp using forward optimization techniques. Comparison of calculations and measurements was successful with agreement of ±2%/2 mm for the energies, segment sizes, depths tested for delivered segments for the dynamic and segmented delivery. Clinical treatment plans performed provided optimal dose coverage of the target while sparing distal organs at risk. Execution of plans using an anthropomorphic phantom to ensure safe and efficient delivery was conducted. Our study validates that MERT is not only possible using the photon MLC, but the efficient and safe delivery inherent with the dynamic delivery provides an ideal technique for shallow tumor treatment.

  17. Recent progress in organic electronics and photonics: A perspective on the future of organic devices

    KAUST Repository

    Bredas, Jean-Luc

    2016-02-25

    The fields of organic electronics and photonics have witnessed remarkable advances over the past few years. This progress bodes well for the increased utilization of organic materials as the active layers in devices for applications as diverse as light-emitting diodes, field-effect transistors, solar cells, or all-optical switches. In the present document, we choose to focus the discussion on organic all-optical switching applications. © 2015 The Japan Society of Applied Physics.

  18. Automated Monte Carlo biasing for photon-generated electrons near surfaces.

    Energy Technology Data Exchange (ETDEWEB)

    Franke, Brian Claude; Crawford, Martin James; Kensek, Ronald Patrick

    2009-09-01

    This report describes efforts to automate the biasing of coupled electron-photon Monte Carlo particle transport calculations. The approach was based on weight-windows biasing. Weight-window settings were determined using adjoint-flux Monte Carlo calculations. A variety of algorithms were investigated for adaptivity of the Monte Carlo tallies. Tree data structures were used to investigate spatial partitioning. Functional-expansion tallies were used to investigate higher-order spatial representations.

  19. Electrons and photons: a probe for short distance study of nuclei

    International Nuclear Information System (INIS)

    Gerard, A.

    1983-01-01

    Study of nuclear interactions using electron and photon beams between 100 and 700 MeV energy has shown the limitations of the mean field theory, and given unambiguous evidence for meson exchange currents and Δ resonance propagation. Continuing the investigation at higher energies (1-3 GeV) would permit to deepen further these discoveries and probe the short and very short range parts of nuclear interactions, thus specifying the role of quarks in the nuclear dynamics [fr

  20. Photon and electron irradiation influence examination on electric properties of BaTiO3

    International Nuclear Information System (INIS)

    Cvetkovic, B.; Manic, G.; Mitic, V.

    1998-01-01

    In order to investigate the influence of photon and electron projectiles from accelerator on electric properties of BaTiO 3 - ceramics, frequent dependence of Z/R ratio is recorded before and after irradiation. Evident differences between frequent dependence of the Z/R ratio recorded on the RLC-meter before and after irradiation for each sample is presented, and that is of practical importance for further application of BaTiO sub 3 - ceramics (author)

  1. Group IV Light Sources to Enable the Convergence of Photonics and Electronics

    Directory of Open Access Journals (Sweden)

    Shinichi eSaito

    2014-09-01

    Full Text Available Group IV lasers are expected to revolutionize chip-to-chip optical communications in terms of cost, scalability, yield, and compatibility to the existing infrastructure of silicon industries for mass production. Here, we review the current state-of-the-art developments of silicon and germanium light sources towards monolithic integration. Quantum confinement of electrons and holes in nano-structures has been the primary route for light emission from silicon, and we can use advanced silicon technologies using top-down patterning processes to fabricate these nano-structures, including fin-type vertical multiple quantum wells. Moreover, the electromagnetic environment can also be manipulated in a photonic crystal nano-cavity to enhance the efficiency of light extraction and emission by the Purcell effect. Germanium is also widely investigated as an active material in Group IV photonics, and novel epitaxial growth technologies are being developed to make a high quality germanium layer on a silicon substrate. To develop a practical germanium laser, various technologies are employed for tensile-stress engineering and high electron doping to compensate the indirect valleys in the conduction band. These challenges are aiming to contribute towards the convergence of electronics and photonics on a silicon chip.

  2. ACCEPT: three-dimensional electron/photon Monte Carlo transport code using combinatorial geometry

    Energy Technology Data Exchange (ETDEWEB)

    Halbleib, J.A. Sr.

    1979-05-01

    The ACCEPT code provides experimenters and theorists with a method for the routine solution of coupled electron/photon transport through three-dimensional multimaterial geometries described by the combinational method. Emphasis is placed upon operational simplicity without sacrificing the rigor of the model. ACCEPT combines condensed-history electron Monte Carlo with conventional single-scattering photon Monte Carlo in order to describe the transport of all generations of particles from several MeV down to 1.0 and 10.0 keV for electrons and photons, respectively. The model is more accurate at the higher energies with a less rigorous description of the particle cascade at energies where the shell structure of the transport media becomes important. Flexibility of construction permits the user to tailor the model to specific applications and to extend the capabilities of the model to more sophisticated applications through relatively simple update procedures. The ACCEPT code is currently running on the CDC-7600 (66000) where the bulk of the cross-section data and the statistical variables are stored in Large Core Memory (Extended Core Storage).

  3. ACCEPT: three-dimensional electron/photon Monte Carlo transport code using combinatorial geometry

    International Nuclear Information System (INIS)

    Halbleib, J.A. Sr.

    1979-05-01

    The ACCEPT code provides experimenters and theorists with a method for the routine solution of coupled electron/photon transport through three-dimensional multimaterial geometries described by the combinational method. Emphasis is placed upon operational simplicity without sacrificing the rigor of the model. ACCEPT combines condensed-history electron Monte Carlo with conventional single-scattering photon Monte Carlo in order to describe the transport of all generations of particles from several MeV down to 1.0 and 10.0 keV for electrons and photons, respectively. The model is more accurate at the higher energies with a less rigorous description of the particle cascade at energies where the shell structure of the transport media becomes important. Flexibility of construction permits the user to tailor the model to specific applications and to extend the capabilities of the model to more sophisticated applications through relatively simple update procedures. The ACCEPT code is currently running on the CDC-7600 (66000) where the bulk of the cross-section data and the statistical variables are stored in Large Core Memory

  4. Penelope-2006: a code system for Monte Carlo simulation of electron and photon transport

    International Nuclear Information System (INIS)

    2006-01-01

    The computer code system PENELOPE (version 2006) performs Monte Carlo simulation of coupled electron-photon transport in arbitrary materials for a wide energy range, from a few hundred eV to about 1 GeV. Photon transport is simulated by means of the standard, detailed simulation scheme. Electron and positron histories are generated on the basis of a mixed procedure, which combines detailed simulation of hard events with condensed simulation of soft interactions. A geometry package called PENGEOM permits the generation of random electron-photon showers in material systems consisting of homogeneous bodies limited by quadric surfaces, i.e. planes, spheres, cylinders, etc. This report is intended not only to serve as a manual of the PENELOPE code system, but also to provide the user with the necessary information to understand the details of the Monte Carlo algorithm. These proceedings contain the corresponding manual and teaching notes of the PENELOPE-2006 workshop and training course, held on 4-7 July 2006 in Barcelona, Spain. (author)

  5. Dose conversion coefficients for high-energy photons, electrons, neutrons and protons

    International Nuclear Information System (INIS)

    Sakamoto, Yukio

    2005-01-01

    Dose conversion coefficients for photons, electrons and neutrons based on new ICRP recommendations were cited in the ICRP Publication 74, but the energy ranges of these data were limited and there are no data for high energy radiations produced in accelerator facilities. For the purpose of designing the high intensity proton accelerator facilities at JAERI, the dose evaluation code system of high energy radiations based on the HERMES code was developed and the dose conversion coefficients of effective dose were evaluated for photons, neutrons and protons up to 10 GeV, and electrons up to 100 GeV. The dose conversion coefficients of effective dose equivalent were also evaluated using quality factors to consider the consistency between radiation weighting factors and Q-L relationship. The effective dose conversion coefficients obtained in this work were in good agreement with those recently evaluated by using FLUKA code for photons and electrons with all energies, and neutrons and protons below 500 MeV. There were some discrepancy between two data owing to the difference of cross sections in the nuclear reaction models. The dose conversion coefficients of effective dose equivalents for high energy radiations based on Q-L relation in ICRP Publication 60 were evaluated only in this work. The previous comparison between effective dose and effective dose equivalent made it clear that the radiation weighting factors for high energy neutrons and protons were overestimated and the modification was required. (author)

  6. Sol-gel coated ion sources for liquid chromatography-direct electron ionization mass spectrometry.

    Science.gov (United States)

    Riboni, Nicolò; Magrini, Laura; Bianchi, Federica; Careri, Maria; Cappiello, Achille

    2017-07-25

    Advances in interfacing liquid chromatography and electron ionization mass spectrometry are presented. New ion source coatings synthesized by sol-gel technology were developed and tested as vaporization surfaces in terms of peak intensity, peak width and peak delay for the liquid chromatography-direct electron ionization mass spectrometry (Direct-EI) determination of environmental pollutants like polycyclic aromatic hydrocarbons and steroids. Silica-, titania-, and zirconia-based coatings were sprayed inside the stainless steel ion source and characterized in terms of thermal stability, film thickness and morphology. Negligible weight losses until 350-400 °C were observed for all the materials, with coating thicknesses in the 6 (±1)-11 (±2) μm range for optimal ionization process. The best performances in terms of both peak intensity and peak width were obtained by using the silica-based coating: the detection of the investigated compounds was feasible at low ng μl -1 levels with a good precision (RSD < 9% for polycyclic aromatic hydrocarbons and <11% for hormones). Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Proceedings of the Workshop on future of nuclear physics in Europe with polarized electrons and photons

    International Nuclear Information System (INIS)

    Didelez, J.P.; Tamas, G.

    1990-01-01

    In the proceedings of the workshop, held at the Institut de Physique Nucleaire in Orsay, France, full texts of 20 contributions are presented. The two main topics were polarized electrons and polarized photons. It has been reported that significant processes have been made recently in the science and technology of polarized electron sources, polarized targets and polarimeters. The relevant tools are therefore now available to complete extensive experimental programs. The 20 papers are indexed and abstracted separately for the INIS database. (R.P.)

  8. Two-Photon-Exchange Correction to Parity-Violating Elastic Electron-Proton Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Andrei Afanasev; Carl Carlson

    2005-02-01

    Higher-order QED effects play an important role in precision measurements of nucleon elastic form factors in electron scattering. Here we introduce a two-photon exchange QED correction to the parity-violating polarization asymmetry of elastic electron-proton scattering. We calculate this correction in the parton model using the formalism of generalized parton distributions, and demonstrate that it can reach several per cent in certain kinematics, becoming comparable in size with existing experimental measurements of strange-quark effects in the proton neutral weak current.

  9. Internal photon and electron dosimetry of the newborn patient—a hybrid computational phantom study

    Science.gov (United States)

    Wayson, Michael; Lee, Choonsik; Sgouros, George; Treves, S. Ted; Frey, Eric; Bolch, Wesley E.

    2012-03-01

    Estimates of radiation absorbed dose to organs of the nuclear medicine patient are a requirement for administered activity optimization and for stochastic risk assessment. Pediatric patients, and in particular the newborn child, represent that portion of the patient population where such optimization studies are most crucial owing to the enhanced tissue radiosensitivities and longer life expectancies of this patient subpopulation. In cases where whole-body CT imaging is not available, phantom-based calculations of radionuclide S values—absorbed dose to a target tissue per nuclear transformation in a source tissue—are required for dose and risk evaluation. In this study, a comprehensive model of electron and photon dosimetry of the reference newborn child is presented based on a high-resolution hybrid-voxel phantom from the University of Florida (UF) patient model series. Values of photon specific absorbed fraction (SAF) were assembled for both the reference male and female newborn using the radiation transport code MCNPX v2.6. Values of electron SAF were assembled in a unique and time-efficient manner whereby the collisional and radiative components of organ dose--for both self- and cross-dose terms—were computed separately. Dose to the newborn skeletal tissues were assessed via fluence-to-dose response functions reported for the first time in this study. Values of photon and electron SAFs were used to assemble a complete set of S values for some 16 radionuclides commonly associated with molecular imaging of the newborn. These values were then compared to those available in the OLINDA/EXM software. S value ratios for organ self-dose ranged from 0.46 to 1.42, while similar ratios for organ cross-dose varied from a low of 0.04 to a high of 3.49. These large discrepancies are due in large part to the simplistic organ modeling in the stylized newborn model used in the OLINDA/EXM software. A comprehensive model of internal dosimetry is presented in this study for

  10. An ultrafast NbN hot-electron single-photon detector for electronic applications

    International Nuclear Information System (INIS)

    Lipatov, A; Okunev, O; Smirnov, K; Chulkova, G; Korneev, A; Kouminov, P; Gol'tsman, G; Zhang, J; Slysz, W; Verevkin, A; Sobolewski, R

    2002-01-01

    We present the latest generation of our superconducting single-photon detector (SPD), which can work from ultraviolet to mid-infrared optical radiation wavelengths. The detector combines a high speed of operation and low jitter with high quantum efficiency (QE) and very low dark count level. The technology enhancement allows us to produce ultrathin (3.5 nm thick) structures that demonstrate QE hundreds of times better, at 1.55 μm, than previous 10 nm thick SPDs. The best, 10x10 μm 2 , SPDs demonstrate QE up to 5% at 1.55 μm and up to 11% at 0.86 μm. The intrinsic detector QE, normalized to the film absorption coefficient, reaches 100% at bias currents above 0.9 I c for photons with wavelengths shorter than 1.3 μm

  11. Photon-photon colliders

    Energy Technology Data Exchange (ETDEWEB)

    Sessler, A.M.

    1995-04-01

    Since the seminal work by Ginsburg, et at., the subject of giving the Next Linear Collider photon-photon capability, as well as electron-positron capability, has drawn much attention. A 1990 article by V.I. Teinov describes the situation at that time. In March 1994, the first workshop on this subject was held. This report briefly reviews the physics that can be achieved through the photon-photon channel and then focuses on the means of achieving such a collider. Also reviewed is the spectrum of backscattered Compton photons -- the best way of obtaining photons. We emphasize the spectrum actually obtained in a collider with both polarized electrons and photons (peaked at high energy and very different from a Compton spectrum). Luminosity is estimated for the presently considered colliders, and interaction and conversion-point geometries are described. Also specified are laser requirements (such as wavelength, peak power, and average power) and the lasers that might be employed. These include conventional and free-electron lasers. Finally, we describe the R&D necessary to make either of these approaches viable and explore the use of the SLC as a test bed for a photon-photon collider of very high energy.

  12. Clinical application of intensity and energy modulated radiotherapy with photon and electron beams

    International Nuclear Information System (INIS)

    Xiangkui Mu

    2005-01-01

    In modern, advanced radiotherapy (e.g. intensity modulated photon radiotherapy, IMXT) the delivery time for each fraction becomes prolonged to 10-20 minutes compared with the conventional, commonly 2-5 minutes. The biological effect of this prolongation is not fully known. The large number of beam directions in IMXT commonly leads to a large integral dose in the patient. Electrons would reduce the integral dose but are not suitable for treating deep-seated tumour, due to their limited penetration in tissues. By combining electron and photon beams, the dose distributions may be improved compared with either used alone. One obstacle for using electron beams in clinical routine is that there is no available treatment planning systems that optimise electron beam treatments in a similar way as for IMXT. Protons have an even more pronounced dose fall-off, larger penetration depth and less penumbra widening than electrons and are therefore more suitable for advanced radiotherapy. However, proton facilities optimised for advanced radiotherapy are not commonly available. In some instances electron beams may be an acceptable surrogate. The first part of this study is an experimental in vitro study where the situation in a tumour during fractionated radiotherapy is simulated. The effect of the prolonged fraction time is compared with the predictions by radiobiological models. The second part is a treatment planning study to analyse the mixing of electron and photon beams for at complex target volume in comparison with IMXT. In the next step a research version of an electron beam optimiser was used for the improvement of treatment plans. The aim was to develop a method for translating crude energy and intensity matrices for optimised electrons into a deliverable treatment plan without destroying the dose distribution. In the final part, different methods of treating the spinal canal in medulloblastoma were explored in a treatment planning study that was evaluated with

  13. The use of angle resolved electron and photon stimulated desorption for the determination of molecular structure at surfaces

    International Nuclear Information System (INIS)

    Madey, T.E.; Stockbauer, R.

    1983-01-01

    A brief review of recent data related to the use of angle-resolved electron stimulated desorption and photon stimulated desorption in determining the structures of molecules at surfaces is made. Examples include a variety of structural assignments based on ESIAD (electron stimulated desorption ion angular distributions), the observation of short-range local ordering effects induced in adsorbed molecules by surface impurities, and the application of photon stimulated desorption to both ionic and covalent adsorbate systems. (Author) [pt

  14. Ant colony algorithm implementation in electron and photon Monte Carlo transport: Application to the commissioning of radiosurgery photon beams

    International Nuclear Information System (INIS)

    Garcia-Pareja, S.; Galan, P.; Manzano, F.; Brualla, L.; Lallena, A. M.

    2010-01-01

    Purpose: In this work, the authors describe an approach which has been developed to drive the application of different variance-reduction techniques to the Monte Carlo simulation of photon and electron transport in clinical accelerators. Methods: The new approach considers the following techniques: Russian roulette, splitting, a modified version of the directional bremsstrahlung splitting, and the azimuthal particle redistribution. Their application is controlled by an ant colony algorithm based on an importance map. Results: The procedure has been applied to radiosurgery beams. Specifically, the authors have calculated depth-dose profiles, off-axis ratios, and output factors, quantities usually considered in the commissioning of these beams. The agreement between Monte Carlo results and the corresponding measurements is within ∼3%/0.3 mm for the central axis percentage depth dose and the dose profiles. The importance map generated in the calculation can be used to discuss simulation details in the different parts of the geometry in a simple way. The simulation CPU times are comparable to those needed within other approaches common in this field. Conclusions: The new approach is competitive with those previously used in this kind of problems (PSF generation or source models) and has some practical advantages that make it to be a good tool to simulate the radiation transport in problems where the quantities of interest are difficult to obtain because of low statistics.

  15. Ant colony algorithm implementation in electron and photon Monte Carlo transport: Application to the commissioning of radiosurgery photon beams

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Pareja, S.; Galan, P.; Manzano, F.; Brualla, L.; Lallena, A. M. [Servicio de Radiofisica Hospitalaria, Hospital Regional Universitario ' ' Carlos Haya' ' , Avda. Carlos Haya s/n, E-29010 Malaga (Spain); Unidad de Radiofisica Hospitalaria, Hospital Xanit Internacional, Avda. de los Argonautas s/n, E-29630 Benalmadena (Malaga) (Spain); NCTeam, Strahlenklinik, Universitaetsklinikum Essen, Hufelandstr. 55, D-45122 Essen (Germany); Departamento de Fisica Atomica, Molecular y Nuclear, Universidad de Granada, E-18071 Granada (Spain)

    2010-07-15

    Purpose: In this work, the authors describe an approach which has been developed to drive the application of different variance-reduction techniques to the Monte Carlo simulation of photon and electron transport in clinical accelerators. Methods: The new approach considers the following techniques: Russian roulette, splitting, a modified version of the directional bremsstrahlung splitting, and the azimuthal particle redistribution. Their application is controlled by an ant colony algorithm based on an importance map. Results: The procedure has been applied to radiosurgery beams. Specifically, the authors have calculated depth-dose profiles, off-axis ratios, and output factors, quantities usually considered in the commissioning of these beams. The agreement between Monte Carlo results and the corresponding measurements is within {approx}3%/0.3 mm for the central axis percentage depth dose and the dose profiles. The importance map generated in the calculation can be used to discuss simulation details in the different parts of the geometry in a simple way. The simulation CPU times are comparable to those needed within other approaches common in this field. Conclusions: The new approach is competitive with those previously used in this kind of problems (PSF generation or source models) and has some practical advantages that make it to be a good tool to simulate the radiation transport in problems where the quantities of interest are difficult to obtain because of low statistics.

  16. Role of electron back action on photons in hybridizing double-layer graphene plasmons with localized photons

    Science.gov (United States)

    Huang, Danhong; Iurov, Andrii; Gumbs, Godfrey

    2018-05-01

    In this paper, we deal with the electromagnetic coupling between an incident surface-plasmon-polariton wave and relativistic electrons in two graphene layers. Our previous investigation was limited to single-layer graphene (Iurov et al 2017 Phys. Rev. B 96 081408). However, the present work, is both an expanded and extended version of this previous Phys. Rev. B paper after having included very detailed theoretical formalisms and extensive comparisons of results from either one or two graphene layers embedded in a dielectric medium. The additional retarded Coulomb interaction between two graphene layers will compete with the coupling between the single graphene layer and the surface of a conductor. Consequently, some distinctive features, such as triply-hybridized absorption peaks and a new acoustic-like graphene plasmon mode within the anticrossing region, have been found for the double-layer graphene system. Physically, our theory is self-consistent, in comparison with a commonly adopted perturbative theory, for studying hybrid light-plasmon modes and the electron back action on photons. Instead of usual radiation or grating-deflection field coupling, a surface-plasmon-polariton localized field coupling is introduced with completely different dispersion relations for radiative (small wave numbers) and evanescent (large wave numbers) field modes. Technically, the exactly calculated effective scattering matrix for this theory can be employed to construct an effective-medium theory in order to improve the accuracy of the well-known finite-difference time-domain method for solving Maxwell’s equations numerically. Practically, the predicted triply-hybridized absorption peaks can excite polaritons only, giving rise to a possible polariton-condensation based laser.

  17. Dielectric laser acceleration of non-relativistic electrons at a photonic structure

    Energy Technology Data Exchange (ETDEWEB)

    Breuer, John

    2013-08-29

    This thesis reports on the observation of dielectric laser acceleration of non-relativistic electrons via the inverse Smith-Purcell effect in the optical regime. Evanescent modes in the vicinity of a periodic grating structure can travel at the same velocity as the electrons along the grating surface. A longitudinal electric field component is used to continuously impart momentum onto the electrons. This is only possible in the near-field of a suitable photonic structure, which means that the electron beam has to pass the structure within about one wavelength. In our experiment we exploit the third spatial harmonic of a single fused silica grating excited by laser pulses derived from a Titanium:sapphire oscillator and accelerate non-relativistic 28 keV electrons. We measure a maximum energy gain of 280 eV, corresponding to an acceleration gradient of 25 MeV/m, already comparable with state-of-the-art radio-frequency linear accelerators. To experience this acceleration gradient the electrons approach the grating closer than 100 nm. We present the theory behind grating-based particle acceleration and discuss simulation results of dielectric laser acceleration in the near-field of photonic grating structures, which is excited by near-infrared laser light. Our measurements show excellent agreement with our simulation results and therefore confirm the direct acceleration with the light field. We further discuss the acceleration inside double grating structures, dephasing effects of non-relativistic electrons as well as the space charge effect, which can limit the attainable peak currents of these novel accelerator structures. The photonic structures described in this work can be readily concatenated and therefore represent a scalable realization of dielectric laser acceleration. Furthermore, our structures are directly compatible with the microstructures used for the acceleration of relativistic electrons demonstrated in parallel to this work by our collaborators in

  18. Dielectric laser acceleration of non-relativistic electrons at a photonic structure

    International Nuclear Information System (INIS)

    Breuer, John

    2013-01-01

    This thesis reports on the observation of dielectric laser acceleration of non-relativistic electrons via the inverse Smith-Purcell effect in the optical regime. Evanescent modes in the vicinity of a periodic grating structure can travel at the same velocity as the electrons along the grating surface. A longitudinal electric field component is used to continuously impart momentum onto the electrons. This is only possible in the near-field of a suitable photonic structure, which means that the electron beam has to pass the structure within about one wavelength. In our experiment we exploit the third spatial harmonic of a single fused silica grating excited by laser pulses derived from a Titanium:sapphire oscillator and accelerate non-relativistic 28 keV electrons. We measure a maximum energy gain of 280 eV, corresponding to an acceleration gradient of 25 MeV/m, already comparable with state-of-the-art radio-frequency linear accelerators. To experience this acceleration gradient the electrons approach the grating closer than 100 nm. We present the theory behind grating-based particle acceleration and discuss simulation results of dielectric laser acceleration in the near-field of photonic grating structures, which is excited by near-infrared laser light. Our measurements show excellent agreement with our simulation results and therefore confirm the direct acceleration with the light field. We further discuss the acceleration inside double grating structures, dephasing effects of non-relativistic electrons as well as the space charge effect, which can limit the attainable peak currents of these novel accelerator structures. The photonic structures described in this work can be readily concatenated and therefore represent a scalable realization of dielectric laser acceleration. Furthermore, our structures are directly compatible with the microstructures used for the acceleration of relativistic electrons demonstrated in parallel to this work by our collaborators in

  19. In situ electrical and thermal monitoring of printed electronics by two-photon mapping.

    Science.gov (United States)

    Pastorelli, Francesco; Accanto, Nicolò; Jørgensen, Mikkel; van Hulst, Niek F; Krebs, Frederik C

    2017-06-19

    Printed electronics is emerging as a new, large scale and cost effective technology that will be disruptive in fields such as energy harvesting, consumer electronics and medical sensors. The performance of printed electronic devices relies principally on the carrier mobility and molecular packing of the polymer semiconductor material. Unfortunately, the analysis of such materials is generally performed with destructive techniques, which are hard to make compatible with in situ measurements, and pose a great obstacle for the mass production of printed electronics devices. A rapid, in situ, non-destructive and low-cost testing method is needed. In this study, we demonstrate that nonlinear optical microscopy is a promising technique to achieve this goal. Using ultrashort laser pulses we stimulate two-photon absorption in a roll coated polymer semiconductor and map the resulting two-photon induced photoluminescence and second harmonic response. We show that, in our experimental conditions, it is possible to relate the total amount of photoluminescence detected to important material properties such as the charge carrier density and the molecular packing of the printed polymer material, all with a spatial resolution of 400 nm. Importantly, this technique can be extended to the real time mapping of the polymer semiconductor film, even during the printing process, in which the high printing speed poses the need for equally high acquisition rates.

  20. Photon drag investigations of current relaxation processes in a two-dimensional electron gas

    CERN Document Server

    Graf, S; Kohler, K U; Bachtold, W

    2000-01-01

    We have investigated the photon drag current that is excited by an infrared laser beam in the plane of the two-dimensional electron gas of GaAs/Al/sub 0.35/Ga/sub 0.65/As multiple-quantum-well systems. An analysis of the spectral response, measured with the picosecond infrared pulses of the wavelength-tunable free electron laser source FELIX, is presented for different doping schemes and examined as a function of temperature and intensity. The influence of the subband- selective scattering by a delta doping is explored, which demonstrates that the photon drag spectral response allows the determination of the momentum relaxation time ratio, R= tau /sub 1// tau /sub 2/, of the electrons in the ground and excited subbands. The relaxation time ratio is found to be surprisingly constant over a large temperature range. The variation of the ratio with intensity can be attributed to heating of the electron gas, whose temperature exceeds 1000 K at saturation intensity. (41 refs).

  1. Penelope - a code system for Monte Carlo simulation of electron and photon transport

    International Nuclear Information System (INIS)

    2003-01-01

    Radiation is used in many applications of modern technology. Its proper handling requires competent knowledge of the basic physical laws governing its interaction with matter. To ensure its safe use, appropriate tools for predicting radiation fields and doses, as well as pertinent regulations, are required. One area of radiation physics that has received much attention concerns electron-photon transport in matter. PENELOPE is a modern, general-purpose Monte Carlo tool for simulating the transport of electrons and photons, which is applicable for arbitrary materials and in a wide energy range. PENELOPE provides quantitative guidance for many practical situations and techniques, including electron and X-ray spectroscopies, electron microscopy and microanalysis, biophysics, dosimetry, medical diagnostics and radiotherapy, as well as radiation damage and shielding. These proceedings contain the extensively revised teaching notes of the second workshop/training course on PENELOPE held in 2003, along with a detailed description of the improved physic models, numerical algorithms and structure of the code system. (author)

  2. The ESTRO-EQUAL quality assurance network for photon and electron radiotherapy beams in Germany

    International Nuclear Information System (INIS)

    Ferreira, I.H.; Dutreix, A.; Richter, J.; Bridier, A.; Chavaudra, J.; Svensson, H.

    2001-01-01

    Background: In 1998 an ESTRO Quality Assurance Network for radiotherapy (EQUAL) has been set up for 25 European countries for photon and electron beams in reference and non-reference conditions. Material and Methods: Measurements are done using LiF powder (DTL937-Philitech, France) that is processed with the PCL3 automatic reader (Fimel-PTW). The participating centers irradiate the TLDs with an absorbed dose of 2 Gy according to the clinical routine. Results: Until September 2000 EQUAL has checked 135 photon beams (including the beams rechecked) from 51 radiotherapy centers in Germany out of 86 accepted centers. The results show that 2% of the beam outputs in reference conditions and 3% of the percentage depth doses are outside the tolerance level (deviation > ± 5%). 6% of the beam output variations and of the wedge transmission factors show deviations > ± 5%. The global analysis of results shows deviations > ± 5% in at least one parameter for 18 beams out of the 135 beams checked. Five rechecked beams present one ''real dosimetric'' problem in one or more parameters, corresponding to 4% of the 114 beams for which the deviations cannot be attributed to set-up errors. - The EQUAL network has checked 89 electron beams in Germany. The results show that all beam outputs checked are within the tolerance level. The standard deviation for the beam output in reference conditions is 2.0% and 2.2% for the beam output for the others field sizes. The percentage of deviations > 3% and ≤ 5% for the reference beam output is higher for electron beams than for photon beam checks. Therefore the electron beam calibration and the TPS algorithms should be improved to increase the accuracy of the patient dosimetry for radiotherapy. (orig.) [de

  3. Handbook of theoretical atomic physics. Data for photon absorption, electron scattering, and vacancies decay

    Energy Technology Data Exchange (ETDEWEB)

    Amusia, Miron [Hebrew Univ., Jerusalem (Israel). Racah Inst. of Physics; Ioffe Physico-Technical Inst., St. Petersburg (Russian Federation); Chernysheva, Larissa [Ioffe Physico-Technical Inst., St. Petersburg (Russian Federation); Yarzhemsky, Victor [Kurnakov Institute of General and Inorganic Chemistry, Moscow (Russian Federation)

    2012-07-01

    The aim of this book is to present highly accurate and extensive theoretical Atomic data and to give a survey of selected calculational methods for atomic physics, used to obtain these data. The book presents the results of calculations of cross sections and probabilities of a broad variety of atomic processes with participation of photons and electrons, namely on photoabsorption, electron scattering and accompanying effects. Included are data for photoabsorption and electron scattering cross-sections and probabilities of vacancy decay formed for a large number of atoms and ions. Attention is also given to photoionization and vacancy decay in endohedrals and to positron-atom scattering. The book is richly illustrated. The methods used are one-electron Hartree-Fock and the technique of Feynman diagrams that permits to include many-electron correlations. This is done in the frames of the Random Phase approximation with exchange and the many-body perturbation theory. Newly obtained and previously collected atomic data are presented. The atomic data are useful for investigating the electronic structure and physical processes in solids and liquids, molecules and clusters, astronomical objects, solar and planet atmospheres and atomic nucleus. Deep understanding of chemical reactions and processes is reached by deep and accurate knowledge of atomic structure and processes with participation of atoms. This book is useful for theorists performing research in different domains of contemporary physics, chemistry and biology, technologists working on production of new materials and for experimentalists performing research in the field of photon and electron interaction with atoms, molecules, solid bodies and liquids.

  4. A novel method of estimating dose responses for polymer gels using texture analysis of scanning electron microscopy images.

    Directory of Open Access Journals (Sweden)

    Cheng-Ting Shih

    Full Text Available Polymer gels are regarded as a potential dosimeter for independent validation of absorbed doses in clinical radiotherapy. Several imaging modalities have been used to convert radiation-induced polymerization to absorbed doses from a macro-scale viewpoint. This study developed a novel dose conversion mechanism by texture analysis of scanning electron microscopy (SEM images. The modified N-isopropyl-acrylamide (NIPAM gels were prepared under normoxic conditions, and were administered radiation doses from 5 to 20 Gy. After freeze drying, the gel samples were sliced for SEM scanning with 50×, 500×, and 3500× magnifications. Four texture indices were calculated based on the gray level co-occurrence matrix (GLCM. The results showed that entropy and homogeneity were more suitable than contrast and energy as dose indices for higher linearity and sensitivity of the dose response curves. After parameter optimization, an R (2 value of 0.993 can be achieved for homogeneity using 500× magnified SEM images with 27 pixel offsets and no outlier exclusion. For dose verification, the percentage errors between the prescribed dose and the measured dose for 5, 10, 15, and 20 Gy were -7.60%, 5.80%, 2.53%, and -0.95%, respectively. We conclude that texture analysis can be applied to the SEM images of gel dosimeters to accurately convert micro-scale structural features to absorbed doses. The proposed method may extend the feasibility of applying gel dosimeters in the fields of diagnostic radiology and radiation protection.

  5. Single-photon emission associated with double electron capture in F9 ++C collisions

    Science.gov (United States)

    Elkafrawy, T.; Simon, A.; Tanis, J. A.; Warczak, A.

    2016-10-01

    Radiative double electron capture (RDEC), the one-step process occurring in ion-atom collisions, has been investigated for bare fluorine ions colliding with carbon. RDEC is completed when two target electrons are captured to a bound state of a projectile simultaneously with the emission of a single photon. This work is a follow-up to our earlier measurement of RDEC for bare oxygen projectiles, thus providing a recipient system free of electron-related Coulomb fields in both cases and allowing for the comparison between the two collision systems as well as with available theoretical studies. The most significant mechanisms of x-ray emission that may contribute to the RDEC energy region as background processes are also addressed.

  6. Space applications of the MITS electron-photon Monte Carlo transport code system

    International Nuclear Information System (INIS)

    Kensek, R.P.; Lorence, L.J.; Halbleib, J.A.; Morel, J.E.

    1996-01-01

    The MITS multigroup/continuous-energy electron-photon Monte Carlo transport code system has matured to the point that it is capable of addressing more realistic three-dimensional adjoint applications. It is first employed to efficiently predict point doses as a function of source energy for simple three-dimensional experimental geometries exposed to simulated uniform isotropic planar sources of monoenergetic electrons up to 4.0 MeV. Results are in very good agreement with experimental data. It is then used to efficiently simulate dose to a detector in a subsystem of a GPS satellite due to its natural electron environment, employing a relatively complex model of the satellite. The capability for survivability analysis of space systems is demonstrated, and results are obtained with and without variance reduction

  7. Metallic Na formation in NaCl crystals with irradiation of electron or vacuum ultraviolet photon

    Energy Technology Data Exchange (ETDEWEB)

    Owaki, Shigehiro [Osaka Prefecture Univ., Sakai, Osaka (Japan). Coll. of Integrated Arts and Sciences; Koyama, Shigeko; Takahashi, Masao; Kamada, Masao; Suzuki, Ryouichi

    1997-03-01

    Metallic Na was formed in NaCl single crystals with irradiation of a variety of radiation sources and analyzed the physical states with several methods. In the case of irradiation of 21 MeV electron pulses to the crystal blocks, the optical absorption and lifetime measurement of positron annihilation indicated appearance of Na clusters inside. Radiation effects of electron beam of 30 keV to the crystals in vacuum showed the appearance of not only metallic Na but atomic one during irradiation with Auger electron spectroscopy. Intense photon fluxes in vacuum ultraviolet region of synchrotron radiation were used as another source and an analyzing method of ultraviolet photoelectron spectroscopy. The results showed the metallic Na layered so thick that bulk plasmon can exist. (author)

  8. arXiv Single-electron and single-photon sensitivity with a silicon Skipper CCD

    CERN Document Server

    Tiffenberg, Javier; Drlica-Wagner, Alex; Essig, Rouven; Guardincerri, Yann; Holland, Steve; Volansky, Tomer; Yu, Tien-Tien

    2017-09-26

    We have developed ultralow-noise electronics in combination with repetitive, nondestructive readout of a thick, fully depleted charge-coupled device (CCD) to achieve an unprecedented noise level of 0.068  e- rms/pixel. This is the first time that discrete subelectron readout noise has been achieved reproducible over millions of pixels on a stable, large-area detector. This enables the contemporaneous, discrete, and quantized measurement of charge in pixels, irrespective of whether they contain zero electrons or thousands of electrons. Thus, the resulting CCD detector is an ultra-sensitive calorimeter. It is also capable of counting single photons in the optical and near-infrared regime. Implementing this innovative non-destructive readout system has a negligible impact on CCD design and fabrication, and there are nearly immediate scientific applications. As a particle detector, this CCD will have unprecedented sensitivity to low-mass dark matter particles and coherent neutrino-nucleus scattering, while ...

  9. Single-photon emission associated with double electron capture in F9+ + C collisions

    CERN Document Server

    Elkafrawy, Tamer; Tanis, John A; Warczak, Andrzej

    2016-01-01

    Radiative double electron capture (RDEC), the one-step process occurring in ion-atom collisions, has been investigated for bare fluorine ions colliding with carbon. RDEC is completed when two target electrons are captured to a bound state of a projectile simultaneously with the emission of a single photon. This work is a follow-up to our earlier measurement of RDEC for bare oxygen projectiles, thus providing a recipient system free of electron-related Coulomb fields in both cases and allowing for the comparison between the two collision systems as well as with available theoretical studies. The most significant mechanisms of x-ray emission that may contribute to the RDEC energy region as background processes are also addressed.

  10. Determination of scatter factor parameters and electron disequilibrium for monoenergetic photon beams.

    Science.gov (United States)

    McDonough, J; Bloch, P; Bjärngard, B E

    1999-02-01

    The tissue-phantom-ratio (TPR) is expressed as the product of the phantom scatter factor (SF), an electron disequilibrium factor, and an attenuation factor, equal to the zero-area TPR. The scatter factor, as a function of depth d and field size s, has been described by two parameters a and w, SF(d,s) = 1 + asd/(ws + d). We have determined the parameters a and w for 20 monoenergetic photon beams between 1 and 20 MeV. Pencil-beam energy-deposition kernels were obtained using Monte Carlo simulations. The kernels were used to calculate broad-beam depth-dose data, which were converted to TPR and fitted to the equation above using an iterative search over a-w space. The parameter a is nearly equal to the attenuation coefficient for all energies while the parameter w increases with energy. The resulting a and w compare favorably to values determined for clinical photon beams, as a function of the measured attenuation coefficient. With the scatter factor determined, we isolated the electron disequilibrium factor for each monoenergetic beam. It can be characterized as a quadratic function of the depth. The coefficients of the quadratic function can be related to the range of the most energetic secondary electron produced.

  11. DOSEFACTOR-DOE, Dose Rate Conversion Factors for Photon and Electron Exposure

    International Nuclear Information System (INIS)

    1993-01-01

    1 - Description of program or function: DOSFACTER-DOE is a revision of the DOSFACTER-II code. It estimates dose-rate conversion factors for exposure to photons and electrons emitted by radionuclides dispersed in the environment. The exposure modes considered are immersion in contaminated air, immersion in contaminated water, and irradiation at a height of 1 m above a contaminated ground surface. The source region for each exposure mode is assumed to be effectively infinite or semi-infinite in extent with a uniform radionuclide concentration throughout the source region. The dose-rate factors are computed for a dose to 23 body organs and for an effective dose. The present code differs from DOSEFACTER-II as follows: no body surface factors, 'total body' factors replaced by 'effective' (weighted) factors, electron dose factors for the skin calculated for several depths, and output format. Non-SI units are used. 2 - Method of solution: For air and water immersion, the body-surface dose-rate factors were based on the conservation of energy requirement that all of the emitted energy is absorbed in the infinite medium. For ground-surface exposure, the body-surface dose-rate factors were calculated at a point 1 m above the ground using a point-kernel integration method and known specific absorbed fractions for photons and electrons in air. For photons only, the dose-rate factors for 23 body organs were calculated for each exposure mode using the organ dose-rate factors for immersion estimated by Eckerman et al. The radioactive decay data are taken from the data library DLC-80/DRALIST which is available from RSIC. 3 - Restrictions on the complexity of the problem: The code is known to compile correctly only with a FORTRAN IV compiler

  12. Electron and photon spread contributions to the radiological penumbra for small monoenergetic x-ray beam (<=2 MeV)

    Science.gov (United States)

    Pignol, Jean-Philippe; Keller, Brian M.

    2009-05-01

    Our team has previously published that submegavoltage photons could significantly improve the radiological penumbra for small size radiation fields. The present work uses Monte Carlo simulation to evaluate the contributions of secondary electrons and photon scatter to the penumbra region for various field sizes (5, 10, 20, and 40 mm in diameters) and for various monoenergetic photon beams (200, 400, 600, 800, 1000, and 2000 keV, and a standard 6 MV beam), minimizing geometrical and transmission penumbra. For field sizes less than 2 cm in diameter, photon scatter is negligible such that the secondary electrons are the main contributor to the radiological penumbra. Reducing the photon beam energy to the submegavoltage range reduces the range of secondary electrons and eventually improves the beam boundary sharpness. Provided that the geometrical penumbra and patient immobilization system are optimized, submegavoltage photon beams with effective photon energies in the 300 to 600 keV range, present significant advantages for multiple beam stereotactic irradiations of tumors less than 2 cm in diameter.

  13. A preliminary investigation on the interaction between sol-gel immobilized glucose oxidase and freely diffusing glucose by means of two-photon microscopy

    Science.gov (United States)

    Delfino, I.; Portaccio, M.; De Rosa, M.; Lepore, M.

    2013-02-01

    To study immobilized protein interactions with dissolved substrates is a very important topic both from a fundamental and technological standpoint. In the present report we illustrate the preliminary results obtained on sol-gel immobilized glucose oxidase (GOD) using a standard de-scanned two-photon microscope based on a modified confocal scanhead with internal detectors and a Ti:sapphire laser as a source. Data acquisition conditions were preliminary defined using functionalized beads of different dimensions. Various sol-gel supports were then investigated by monitoring endogeneous fluorescence due to the flavoadenine (FAD) molecules, present in GOD. Linear absorption and fluorescence spectroscopy along with Fourier Transform Infrared microscopy were employed for a full-optical characterization of the samples. The results show that GOD immobilization processes can be successfully monitored in some cases and also the interaction with glucose could be studied by this approach. This assessment holds potentials to better understand the characteristic of immobilized enzymes biocatalysis and to develop new biosensing schemes.

  14. Two-electron double quantum dot coupled to coherent photon and phonon fields

    Science.gov (United States)

    Sato, Yuya; Chen, Jason C. H.; Hashisaka, Masayuki; Muraki, Koji; Fujisawa, Toshimasa

    2017-09-01

    Two-electron states of a double quantum dot (DQD) under irradiation of coherent boson (photon and phonon) fields are studied by measuring spin-flip tunneling current in the Pauli spin blockade regime. This measurement scheme allows us to investigate Rabi splitting and associated boson dressed states particularly in the deep dispersive regime where the detuning δ ≡ℏ ω -EAB between the boson energy ℏ ω and energy spacing EAB of the two-level system is significantly large (δ ˜ℏ ω ), where the permanent dipole moment in the DQD plays a significant role in the hybridization.

  15. Enhanced radiative recombination rate for electron-hole droplets in a silicon photonic crystal nanocavity

    Science.gov (United States)

    Ihara, Toshiyuki; Takahashi, Yasushi; Noda, Susumu; Kanemitsu, Yoshihiko

    2017-07-01

    We investigate photoluminescence (PL) spectra and dynamics of clean silicon photonic crystal nanocavities at 10 K. A sharp emission peak due to the nanocavity mode has the largest intensity when the energy of the nanocavity mode is equal to the emission energy of the electron-hole droplets (EHDs). Time-resolved PL spectroscopy indicates that the PL lifetime of the EHD is reduced to as short as 1.2 ns by the nanocavity mode. A careful analysis of the lifetimes indicates that the radiative recombination rate for EHD is enhanced by a factor of larger than 5 by the Purcell effect.

  16. The design and dosimetric evaluation of tannin-based Rhizophora spp. particleboards as phantoms for high energy photons and electrons

    Science.gov (United States)

    Yusof, M. F. Mohd; Abdullah, R.; Tajuddin, A. A.; Hashim, R.; Bauk, S.; Hamid, P. N. K. Abd

    2018-01-01

    A set of phantom with an external dimension of 30 cm x 30 cm was constructed from tannin-based Rhizophora spp. particleboards similar to the solid water phantoms. The dosimetric characteristics of the particleboard phantoms were evaluated at high energy photons and electrons by measuring the beam output at 6 MV photons and 6 MeV electrons based on the IAEA TRS 398:2000 protocol. The tissue-phantom ratio (TPR20,10) was measured at 6 and 10 MV photons. The beam output calibration of the particleboards was in good agreement to water and solid water phantoms at 6 MV photons with percentage difference of 1.7 and 6.2% respectively. The beam output calibration of the tannin-based Rhizophora spp. particleboards at 6 MeV electrons on the other hand were in excellent agreement to water with percentage difference of 0.3. The percentage depth dose of tannin-based Rhizophora spp. particleboards were in agreement to water and solid water within 4.5% when measured using ionization chamber and EBT2 film. The electron beam parameters of R50, R80 and R90 at 6 MeV electrons also were in good agreement to water and solid water phantoms. The overall results had indicated the suitability of tannin-based Rhizophora spp. particleboards as water substitute phantom materials for high energy photons and electrons.

  17. Calculated photon spectra at several angles for 5- and 50-MeV electron beams striking solid and gas targets

    International Nuclear Information System (INIS)

    Slaughter, D.R.

    1983-01-01

    Coupled electron-photon transport calculations have been carried out to simulate the photon generation when a 5- or 50-MeV electron beam strikes a solid or gas target. Results indicate that a 5-MeV beam striking targets of tungsten wire, air, or air doped with Kr or Xe generates a photon spectrum sharply peaked in the forward direction and with approximately 1/E spectral intensity. At right angles to the beam the photon intensity is predominantly due to characteristic K x-rays. A 50-MeV beam striking the same targets generates substantially higher photon yield in the forward direction, but the yield normal to the beam is similar to that due to the 5-MeV beam. However, positron-electron annihilation radiation constitutes a significant part of the photon radiation normal to the beam, and is more intense than characteristic K x-rays when the target is more than about one-third of the electron range

  18. Hydroxyapatite, fluor-hydroxyapatite and fluorapatite produced via the sol-gel method: bonding to titanium and scanning electron microscopy.

    Science.gov (United States)

    Tredwin, Christopher J; Georgiou, George; Kim, Hae-Won; Knowles, Jonathan C

    2013-05-01

    Hydroxyapatite (HA), fluor-hydroxyapatite (FHA) with varying levels of fluoride ion substitution and fluorapatite (FA) production has been characterised and optimised by the sol-gel method and the dissolution and biological properties of these materials were investigated. It was the objective of this study to investigate the potential bond strength and interaction of these materials with titanium. HA, FHA and FA were synthesised by a sol-gel method. Calcium nitrate and triethyl phosphite were used as precursors under an ethanol-water based solution. Different amounts of ammonium fluoride (NH4F) were incorporated for the preparation of the FHA and FA sol-gels. Using a spin coating technique the sol-gels were coated onto commercially pure titanium disks and crystallised at various temperatures. Using scanning electron microscopy (SEM) and elemental analysis, the surface characteristics, coating thickness and interaction of the Ti substrate and coating were investigated. The bond strengths of the coating to the Ti were investigated using an Instron Universal Load Testing Machine. Statistical analysis was performed with a two-way analysis of variance and post hoc testing with a Bonferroni correction. (1) Coating speed inversely influenced the coating thickness. (2) Increasing fluoride ion substitution and heating temperature significantly increased bond strength and (3) increasing fluoride ion substitution increased the coating thickness. FHA and FA synthesised using the sol-gel technique may offer a superior alternative to coating titanium implants with HA and plasma spraying. HA, FHA and FA materials synthesised by the sol-gel method may also have a use as bone grafting materials. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  19. Dose response of commercially available optically stimulated luminescent detector, Al2O3:C for megavoltage photons and electrons.

    Science.gov (United States)

    Kim, Dong Wook; Chung, Weon Kuu; Shin, Dong Oh; Yoon, Myonggeun; Hwang, Ui-Jung; Rah, Jeong-Eun; Jeong, Hojin; Lee, Sang Yeob; Shin, Dongho; Lee, Se Byeong; Park, Sung Yong

    2012-04-01

    This study examined the dose response of an optically stimulated luminescence dosemeter (OSLD) to megavoltage photon and electron beams. A nanoDot™ dosemeter was used to measure the dose response of the OSLD. Photons of 6-15 MV and electrons of 9-20 MeV were delivered by a Varian 21iX machine (Varian Medical System, Inc. Milpitas, CA, USA). The energy dependency was dose was linear until 200 cGy. The superficial dose measurements revealed photon irradiation to have an angular dependency. The nanoDot™ dosemeter has potential use as an in vivo dosimetric tool that is independent of the energy, has dose linearity and a rapid response compared with normal in vivo dosimetric tools, such as thermoluminescence detectors. However, the OSLD must be treated very carefully due to the high angular dependency of the photon beam.

  20. Electrons and photons at High Level Trigger in CMS for Run II

    CERN Document Server

    Bin Anuar, Afiq Aizuddin

    2015-01-01

    The CMS experiment has been designed with a 2-level trigger system. The first level is implemented using custom-designed electronics. The second level is the so-called High Level Trigger (HLT), a streamlined version of the CMS offline reconstruction software running on a computer farm. For Run II of the Large Hadron Collider, the increase in center-of-mass energy and luminosity will raise the event rate to a level challenging for the HLT algorithms. New approaches have been studied to keep the HLT output rate manageable while maintaining thresholds low enough to cover physics analyses. The strategy mainly relies on porting online the ingredients that have been successfully applied in the offline reconstruction, thus allowing to move HLT selection closer to offline cuts. Improvements in HLT electron and photon definitions will be presented, focusing in particular on updated clustering algorithm and the energy calibration procedure, new Particle-Flow-based isolation approach and pileup mitigation techniques, a...

  1. Parallel FE Electron-Photon Transport Analysis on 2-D Unstructured Mesh

    International Nuclear Information System (INIS)

    Drumm, C.R.; Lorenz, J.

    1999-01-01

    A novel solution method has been developed to solve the coupled electron-photon transport problem on an unstructured triangular mesh. Instead of tackling the first-order form of the linear Boltzmann equation, this approach is based on the second-order form in conjunction with the conventional multi-group discrete-ordinates approximation. The highly forward-peaked electron scattering is modeled with a multigroup Legendre expansion derived from the Goudsmit-Saunderson theory. The finite element method is used to treat the spatial dependence. The solution method is unique in that the space-direction dependence is solved simultaneously, eliminating the need for the conventional inner iterations, a method that is well suited for massively parallel computers

  2. Angular correlation of autoionization electrons and photons emitted from collisionally aligned atomic states

    International Nuclear Information System (INIS)

    Eichler, J.; Fritsch, W.

    1976-01-01

    The angular correlation of autoionization electrons or of photons ejected from collisionally aligned excited atoms is calculated assuming unpolarized beam and target, and polarization-insensitive detectors. Starting from the two-step hypothesis for the formation and decay of the intermediate excited atoms, the angular correlation is expressed in terms of the density matrix describing the excited system. Using the symmetries of the density matrix, a minimal set of independent matrix elements is given and the conditions for which a complete determination of this set is experimentally possible are discussed. For the case of electron emission, simple examples are pointed out in which the angular correlation is independent of the reduced Coulomb matrix elements describing the decay. (author)

  3. ITS, TIGER System of Coupled Electron Photon Transport by Monte-Carlo

    International Nuclear Information System (INIS)

    Halbleib, J.A.; Mehlhorn, T.A.; Young, M.F.

    1996-01-01

    1 - Description of program or function: ITS permits a state-of-the-art Monte Carlo solution of linear time-integrated coupled electron/ photon radiation transport problems with or without the presence of macroscopic electric and magnetic fields of arbitrary spatial dependence. 2 - Method of solution: Through a machine-portable utility that emulates the basic features of the CDC UPDATE processor, the user selects one of eight codes for running on a machine of one of four (at least) major vendors. With the ITS-3.0 release the PSR-0245/UPEML package is included to perform these functions. The ease with which this utility is applied combines with an input scheme based on order-independent descriptive keywords that makes maximum use of defaults and internal error checking to provide experimentalists and theorists alike with a method for the routine but rigorous solution of sophisticated radiation transport problems. Physical rigor is maximized by employing the best available cross sections and sampling distributions, and the most complete physical model for describing the production and transport of the electron/ photon cascade from 1.0 GeV down to 1.0 keV. Flexibility of construction permits the codes to be tailored to specific applications and the capabilities of the codes to be extended to more complex applications through update procedures. 3 - Restrictions on the complexity of the problem: - Restrictions and/or limitations for ITS depend upon the local operating system

  4. Electron and photon energy reconstruction in the electromagnetic calorimeter of ATLAS

    CERN Document Server

    AUTHOR|(CDS)2075753; Mandelli, Luciano

    2007-01-01

    The Atlas LAr electromagnetic calorimeter is designed to provide a precise measurement of electrons and photons energies, in order to meet the requirements coming from the LHC physics program. This request of precision makes important to understand the behavior of the detector in all its aspect. Of fundamental importance to achieve the best possible performances is the calibration of the EM calorimeter, and this is the topic of this thesis. With detailed Monte Carlo simulations of single electrons and photons in the Atlas detector, we find a method to calibrate the electromagnetic calorimeter, based only on the informations that come from it. All the informations needed to develop a calibration method come from the simulations made with the technique of the Calibration Hits, that allows to know the en- ergy deposited in all the materials inside the detector volume, and not only in the active layer of each subdetector as possible in the standard simulations. This technique required a big effort for the develop...

  5. ITS Version 6 : the integrated TIGER series of coupled electron/photon Monte Carlo transport codes.

    Energy Technology Data Exchange (ETDEWEB)

    Franke, Brian Claude; Kensek, Ronald Patrick; Laub, Thomas William

    2008-04-01

    ITS is a powerful and user-friendly software package permitting state-of-the-art Monte Carlo solution of lineartime-independent coupled electron/photon radiation transport problems, with or without the presence of macroscopic electric and magnetic fields of arbitrary spatial dependence. Our goal has been to simultaneously maximize operational simplicity and physical accuracy. Through a set of preprocessor directives, the user selects one of the many ITS codes. The ease with which the makefile system is applied combines with an input scheme based on order-independent descriptive keywords that makes maximum use of defaults and internal error checking to provide experimentalists and theorists alike with a method for the routine but rigorous solution of sophisticated radiation transport problems. Physical rigor is provided by employing accurate cross sections, sampling distributions, and physical models for describing the production and transport of the electron/photon cascade from 1.0 GeV down to 1.0 keV. The availability of source code permits the more sophisticated user to tailor the codes to specific applications and to extend the capabilities of the codes to more complex applications. Version 6, the latest version of ITS, contains (1) improvements to the ITS 5.0 codes, and (2) conversion to Fortran 90. The general user friendliness of the software has been enhanced through memory allocation to reduce the need for users to modify and recompile the code.

  6. Hybrid fluorescence and electron cryo-microscopy for simultaneous electron and photon imaging.

    Science.gov (United States)

    Iijima, Hirofumi; Fukuda, Yoshiyuki; Arai, Yoshihiro; Terakawa, Susumu; Yamamoto, Naoki; Nagayama, Kuniaki

    2014-01-01

    Integration of fluorescence light and transmission electron microscopy into the same device would represent an important advance in correlative microscopy, which traditionally involves two separate microscopes for imaging. To achieve such integration, the primary technical challenge that must be solved regards how to arrange two objective lenses used for light and electron microscopy in such a manner that they can properly focus on a single specimen. To address this issue, both lateral displacement of the specimen between two lenses and specimen rotation have been proposed. Such movement of the specimen allows sequential collection of two kinds of microscopic images of a single target, but prevents simultaneous imaging. This shortcoming has been made up by using a simple optical device, a reflection mirror. Here, we present an approach toward the versatile integration of fluorescence and electron microscopy for simultaneous imaging. The potential of simultaneous hybrid microscopy was demonstrated by fluorescence and electron sequential imaging of a fluorescent protein expressed in cells and cathodoluminescence imaging of fluorescent beads. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. Radiological properties of MAGIC normoxic polymer gel dosimetry

    Science.gov (United States)

    Aljamal, M.; Zakaria, A.; Shamsuddin, S.

    2013-04-01

    For a polymer gel dosimeter to be of use in radiation dosimetry, it should display water-equivalent radiological properties. In this study, the radiological properties of the MAGIC (Methacrylic and Ascorbic acid in Gelatin Initiated by Copper) normoxic polymer gels were investigated. The mass density (ρ) was determined based on Archimedes' principle. The weight fraction of elemental composition and the effective atomic number (Zeff) were calculated. The electron density was also measured with 90° scattering angle at room temperature. The linear attenuation coefficient (μ) of unirradiated gel, irradiated gel, and water were determined using Am-241 based on narrow beam geometry. Monte Carlo simulation was used to calculate the depth doses response of MAGIC gel and water for 6MV photon beam. The weight fractions of elements composition of MAGIC gel were close to that for water. The mass density was found to be 1027 ± 2 kg m-3, which is also very close to mass density of muscle tissue (1030 kg m-3) and 2.7% higher than that of water. The electron density (ρe) and atomic number (Zeff) were found to be 3.43 × 1029 e m-3 and 7.105, respectively. The electron density measured was 2.6% greater than that for water. The atomic number was very close to that for water. The prepared MAGIC gel was found to be water equivalent based on the study of element composition, mass density, electron density and atomic number. The linear attenuation coefficient of unirradiated gel was very close to that of water. The μ of irradiated gel was found to be linear with dose 2-40 Gy. The depth dose response for MAGIC gel from a 6 MV photon beam had a percentage dose difference to water of less than 1%. Therefore it satisfies the criteria to be a good polymer gel dosimeter for radiotherapy.

  8. Electron beam vs. photon beam coverage of the spinal axis in pediatric patients with primary CNS malignancies

    International Nuclear Information System (INIS)

    Paris, Kristie J.; Guan, Tim; Pagliuca, Theresa; Almond, Peter R.; Jose, B. Oliapuram; Lindberg, Robert D.; Spanos, William J.

    1996-01-01

    Purpose: The Purpose of this study is to retrospectively review the treatment of pediatric patients with primary central nervous system tumors requiring cranial spinal radiation therapy. To compare the two treatment techniques used in the coverage of the spinal axis with photon beam versus electron beam. To evaluate local control, survival, acute toxicities and late complication in this population. Materials and Methods: Twenty-nine pediatric patients with primary CNS disease necessitating coverage of the entire cranial spinal axis were treated between 1982 - 1994. Six of twenty-nine were treated with photon beam coverage of their spinal column and twenty-three were treated using a posterior electron beam field. Treatment records and pathology reports were reviewed to evaluate acute tolerance, local control, endocrine abnormalities and status. The treatment planning utilized in each patient was reviewed. Results: The age range was from 14 months to 15 years, with a mean of 7.5 years. There were 18 males, and 11 females in this group of patients. Twenty-nine patients were treated with curative intent. Twenty-two were treated on protocols with and without chemotherapy. Eight of these received concomitant chemotherapy consisting of Vincristine weekly, (5(22)) received pre-radiation chemotherapy. The pathology of these patients were (9(29)) medulloblastoma, with one year minimum follow-up. Five of six patients treated with photon beam, and (12(23)) of the patients treated with the electron beam were alive at the completion of this study. Two of twelve patients who failed in the electron beam group failed distantly as their first site of recurrence. The tolerance for acute effects was best for the electron beam patients. Only(2(23)) of the electron beam group required interruptions in therapy for hemato toxicity, while (6(6)) in the photon group were required interruptions. Nausea and vomiting was observed in (5(23)) electron beam and (5(6)) photon beam. Weight loss

  9. Advanced R ampersand D for electron and photon beams at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Kirk, H.G.

    1989-08-01

    The Brookhaven Accelerator Test Facility consists of a 50-MeV linear accelerator and a laser system capable of generating short (a few picoseconds) laser pulses at both UV (266 nm) and infrared (10 μm) wavelengths. With these systems in place, the ATF has unique capabilities for the study of fundamental interactions between charged-particle beams and intense electromagnetic radiation. The principal research goals of the Accelerator Test Facility (ATF) axe the following. Laser Acceleration Program: We wig study the principles and techniques of particle acceleration at ultra-high frequencies (up to 30 THz) and with very high acceleration gradients (up to 1 GV/m). Production of Coherent Radiation: We wish to develop the next generation of photon sources with features like (a) short pulses (picoseconds or less), (b) coherence, and (c) high peak power. All of these attributes can be provided by free-electron lasers. High-brightness sources: A common denominator for the above programs is the need for electron beams with very small transverse and longitudinal emittances. We will devote a substantial amount of our resources to the production and understanding of electron beams that have these attributes. We will build advanced electron sources such as switched-power devices and rf guns with photocathodes. Important applications of this line of research include the development of high-luminosity linear colliders and free-electron lasers in the XUV regime

  10. Modulated electron radiotherapy treatment planning using a photon multileaf collimator for post-mastectomized chest walls

    International Nuclear Information System (INIS)

    Salguero, Francisco Javier; Palma, Bianey; Arrans, Rafael; Rosello, Joan; Leal, Antonio

    2009-01-01

    Background and purpose: To evaluate the feasibility of using a photon MLC (xMLC) for modulated electron radiotherapy treatment (MERT) as an alternative to conventional post-mastectomy chest wall (CW) irradiation. A Monte Carlo (MC) based planning system was developed to overcome the inaccuracy of the 'pencil beam' algorithm. MC techniques are known to accurately calculate the dose distributions of electron beams, allowing the explicit simulation of electron interactions within the MLC. Materials and methods: Four real clinical CW cases were planned using MERT which were compared with the conventional electron treatments based on blocks and by a straightforward approach using the MLC, and not the blocks (as an intermediate step to MERT) to shape the same segments with SSD between 60 and 70 cm depending on PTV size. MC calculations were verified with an array of ionization chambers and radiochromic films in a solid water phantom. Results: Tests based on gamma analysis between MC dose distributions and radiochromic film measurements showed an excellent agreement. Differences in the absolute dose measured with a plane-parallel chamber at a reference point were below 3% for all cases. MERT solution showed a better PTV coverage and a significant reduction of the doses to the organs at risk (OARs). Conclusion: MERT can effectively improve the current electron treatments by obtaining a better PTV coverage and sparing healthy tissues. More directly, block-shaped treatments could be replaced by MLC-shaped non-modulated segments providing similar results.

  11. Evaluation of the effect of tooth and dental restoration material on electron dose distribution and production of photon contamination in electron beam radiotherapy.

    Science.gov (United States)

    Bahreyni Toossi, Mohammad Taghi; Ghorbani, Mahdi; Akbari, Fatemeh; Mehrpouyan, Mohammad; Sobhkhiz Sabet, Leila

    2016-03-01

    The aim of this study is to evaluate the effect of tooth and dental restoration materials on electron dose distribution and photon contamination production in electron beams of a medical linac. This evaluation was performed on 8, 12 and 14 MeV electron beams of a Siemens Primus linac. MCNPX Monte Carlo code was utilized and a 10 × 10 cm(2) applicator was simulated in the cases of tooth and combinations of tooth and Ceramco C3 ceramic veneer, tooth and Eclipse alloy and tooth and amalgam restoration materials in a soft tissue phantom. The relative electron and photon contamination doses were calculated for these materials. The presence of tooth and dental restoration material changed the electron dose distribution and photon contamination in phantom, depending on the type of the restoration material and electron beam's energy. The maximum relative electron dose was 1.07 in the presence of tooth including amalgam for 14 MeV electron beam. When 100.00 cGy was prescribed for the reference point, the maximum absolute electron dose was 105.10 cGy in the presence of amalgam for 12 MeV electron beam and the maximum absolute photon contamination dose was 376.67 μGy for tooth in 14 MeV electron beam. The change in electron dose distribution should be considered in treatment planning, when teeth are irradiated in electron beam radiotherapy. If treatment planning can be performed in such a way that the teeth are excluded from primary irradiation, the potential errors in dose delivery to the tumour and normal tissues can be avoided.

  12. Bibliography of electron and photon cross sections with atoms and molecules. Published in the 20th century. Methane

    International Nuclear Information System (INIS)

    Hayashi, Makoto

    2004-10-01

    Bibliographies of original and review reports of experiments or theories of electron and photon cross sections and also electron swarm data are presented for atomic or molecular species with specified targets. These works covered 17 atoms and 51 molecules. The present bibliography is only for methane (CH 4 ). About 1050 papers were compiled. A comprehensive author index is included. The bibliography covers the period 1924 through 2000 for CH 4 . Finally, author's comments for CH 4 electron collision cross sections are given. (author)

  13. Transmission microscopy of unmodified biological materials: comparative radiation dosages with electrons and ultrasoft X-ray photons

    International Nuclear Information System (INIS)

    Sayre, D.; Feder, R.; Spiller, E.; Kirz, J.; Kim, D.M.

    1977-01-01

    The minimum radiation dosage in a specimen consistent with transmission microscopy at resolution d and specimen thickness t is calculated for model specimens resembling biological materials in their natural state. The calculations cover 10 4 -10 7 eV electrons and 1.3-90 A photons in a number of microscopy modes. The results indicate that over a considerable part of the (t,d)-plane transmission microscopy on such specimens can be carried out at lower dosage with photons than with electrons. Estimates of the maximum resolutions obtainable with electrons and photons, consistent with structural survival of the specimen, are obtained, as are data on optimal operating conditions for microscopy with the two particles

  14. Dosimetric impact of a CT metal artefact suppression algorithm for proton, electron and photon therapies

    International Nuclear Information System (INIS)

    Wei Jikun; Sandison, George A; Hsi, W-C; Ringor, Michael; Lu Xiaoyi

    2006-01-01

    Accurate dose calculation is essential to precision radiation treatment planning and this accuracy depends upon anatomic and tissue electron density information. Modern treatment planning inhomogeneity corrections use x-ray CT images and calibrated scales of tissue CT number to electron density to provide this information. The presence of metal in the volume scanned by an x-ray CT scanner causes metal induced image artefacts that influence CT numbers and thereby introduce errors in the radiation dose distribution calculated. This paper investigates the dosimetric improvement achieved by a previously proposed x-ray CT metal artefact suppression technique when the suppressed images of a patient with bilateral hip prostheses are used in commercial treatment planning systems for proton, electron or photon therapies. For all these beam types, this clinical image and treatment planning study reveals that the target may be severely underdosed if a metal artefact-contaminated image is used for dose calculations instead of the artefact suppressed one. Of the three beam types studied, the metal artefact suppression is most important for proton therapy dose calculations, intermediate for electron therapy and least important for x-ray therapy but still significant. The study of a water phantom having a metal rod simulating a hip prosthesis indicates that CT numbers generated after image processing for metal artefact suppression are accurate and thus dose calculations based on the metal artefact suppressed images will be of high fidelity

  15. A simplified spherical harmonic method for coupled electron-photon transport calculations

    Energy Technology Data Exchange (ETDEWEB)

    Josef, J.A.

    1997-12-01

    In this thesis the author has developed a simplified spherical harmonic method (SP{sub N} method) and associated efficient solution techniques for 2-D multigroup electron-photon transport calculations. The SP{sub N} method has never before been applied to charged-particle transport. He has performed a first time Fourier analysis of the source iteration scheme and the P{sub 1} diffusion synthetic acceleration (DSA) scheme applied to the 2-D SP{sub N} equations. The theoretical analyses indicate that the source iteration and P{sub 1} DSA schemes are as effective for the 2-D SP{sub N} equations as for the 1-D S{sub N} equations. In addition, he has applied an angular multigrid acceleration scheme, and computationally demonstrated that it performs as well as for the 2-D SP{sub N} equations as for the 1-D S{sub N} equations. It has previously been shown for 1-D S{sub N} calculations that this scheme is much more effective than the DSA scheme when scattering is highly forward-peaked. The author has investigated the applicability of the SP{sub N} approximation to two different physical classes of problems: satellite electronics shielding from geomagnetically trapped electrons, and electron beam problems.

  16. Photon as a classical wave packet from classically stabilized electron orbits

    Science.gov (United States)

    Jonson, Jan Olof

    2007-08-01

    The fact that an orbiting electron does not collapse into the nucleus of its parent atom has thus far been considered a major obstacle to a classical interpretation of the stable states of orbiting electrons. Quantum mechanics avoids the very problem by discussing the probability of finding it, a method that confessedly has been very fruitful in the exploring the behaviour of elementary particles. Nonetheless, why should necessarily those two approaches be regarded as each others' enemies? In this paper it is shown that the classical mechanistic approach is still capable of explaining the eternal, circular movement of an electron around a nucleus. It is possible if reformulating the laws of action involved, returning to the simple electrostatic model, based upon Coulomb's law (1785, 1771). Further, in this paper it is also discussed, how electromagnetic radiation due to the de-excitation of excited electrons, orbiting around a positive nucleus, can be explained classically, as a sudden peak in the otherwise zero electric field, due to the inwards spiralling movement connected to the de-excitation. The concept of a distinct particle, the 'photon' is thereby rejected.

  17. Diamond nanoparticles as a way to improve electron transfer in sol–gel L-lactate biosensing platforms

    Energy Technology Data Exchange (ETDEWEB)

    Briones, M.; Casero, E. [Departamento de Química Analítica y Análisis Instrumental, Facultad de Ciencias, c/Francisco Tomás y Valiente, No7, Campus de Excelencia de la Universidad Autónoma de Madrid, 28049 Madrid (Spain); Vázquez, L. [Instituto de Ciencia de Materiales de Madrid (CSIC), c/Sor Juana Inés de la Cruz No3, Campus de Excelencia de la Universidad Autónoma de Madrid, 28049 Madrid (Spain); Pariente, F.; Lorenzo, E. [Departamento de Química Analítica y Análisis Instrumental, Facultad de Ciencias, c/Francisco Tomás y Valiente, No7, Campus de Excelencia de la Universidad Autónoma de Madrid, 28049 Madrid (Spain); Petit-Domínguez, M.D., E-mail: mdolores.petit@uam.es [Departamento de Química Analítica y Análisis Instrumental, Facultad de Ciencias, c/Francisco Tomás y Valiente, No7, Campus de Excelencia de la Universidad Autónoma de Madrid, 28049 Madrid (Spain)

    2016-02-18

    In the present work, we have included for the first time diamond nanoparticles (DNPs) in a sol–gel matrix derived from (3-mercaptopropyl)-trimethoxysilane (MPTS) in order to improve electron transfer in a lactate oxidase (LOx) based electrochemical biosensing platform. Firstly, an exhaustive AFM study, including topographical, surface potential (KFM) and capacitance gradient (CG) measurements, of each step involved in the biosensing platform development was performed. The platform is based on gold electrodes (Au) modified with the sol–gel matrix (Au/MPTS) in which diamond nanoparticles (Au/MPTS/DNPs) and lactate oxidase (Au/MPTS/DNPs/LOx) have been included. For the sake of comparison, we have also characterized a gold electrode directly modified with DNPs (Au/DNPs). Secondly, the electrochemical behavior of a redox mediator (hydroxymethyl-ferrocene, HMF) was evaluated at the platforms mentioned above. The response of Au/MPTS/DNPs/LOx towards lactate was obtained. A linear concentration range from 0.053 mM to 1.6 mM, a sensitivity of 2.6 μA mM{sup −1} and a detection limit of 16 μM were obtained. These analytical properties are comparable to other biosensors, presenting also as advantages that DNPs are inexpensive, environment-friendly and easy-handled nanomaterials. Finally, the developed biosensor was applied for lactate determination in wine samples. - Highlights: • We have included for the first time diamond nanoparticles (DNPs) in a sol–gel matrix for developing lactate biosensors. • DNPs facilitate electron-transfer within the sol–gel network in electrochemical biosensors. • Lactate biosensors show good sensitivity, detection limit, reproducibility and stability.

  18. 85: Representation of the lack of electronic equilibrium in high energy photon beams using modified scatter tables

    International Nuclear Information System (INIS)

    Rosenwald, J.C.; Drouard, J.; Simonian, M.

    1987-01-01

    The lack of electronic equilibrium in high energy photon beams is significant in the build-up region, at the edge of the beams and at the edge of inhomogeneous structures. The authors propose to use the algorithms based on separation of primary and scatter and to include in the scatter tables a component representing the lack of electronic equilibrium for small depths and small field size. The value and limits of this approach are discussed and illustrated by several examples corresponding to different photon energies in the range 1 to 25 MV. Good agreement between calculations and measurements is obtained in most situations. 6 refs.; 5 figs

  19. Techniques to distinguish between electron and photon induced events using segmented germanium detectors

    Energy Technology Data Exchange (ETDEWEB)

    Kroeninger, K.

    2007-06-05

    Two techniques to distinguish between electron and photon induced events in germanium detectors were studied: (1) anti-coincidence requirements between the segments of segmented germanium detectors and (2) the analysis of the time structure of the detector response. An 18-fold segmented germanium prototype detector for the GERDA neutrinoless double beta-decay experiment was characterized. The rejection of photon induced events was measured for the strongest lines in {sup 60}Co, {sup 152}Eu and {sup 228}Th. An accompanying Monte Carlo simulation was performed and the results were compared to data. An overall agreement with deviations of the order of 5-10% was obtained. The expected background index of the GERDA experiment was estimated. The sensitivity of the GERDA experiment was determined. Special statistical tools were developed to correctly treat the small number of events expected. The GERDA experiment uses a cryogenic liquid as the operational medium for the germanium detectors. It was shown that germanium detectors can be reliably operated through several cooling cycles. (orig.)

  20. Study of unexplained hard photon production by electrons channelled in a crystal

    CERN Multimedia

    2002-01-01

    Our preceding experiment (NA33) designed to study the pair creation process in the interaction of high energy $\\gamma$ with a crystal in alignment conditions had revealed the existence of an unexpected peak in the radiation of 150 GeV e$^{-}$ beam for E$_{\\gamma}$/E$_{e^{-}} \\simeq$ 0.85 incident along the axis of a 185 $\\mu$m. Ge crystal and the photon multiplicity for the peak events has been measured to be M $\\simeq$ 5.7.\\\\ In NA42, in a 76 $\\mu$m crystal of the same crystallographic quality, the peak nearly disappears, and the photon multiplicity at x = 0.85 is only M $\\simeq$ 2.0. \\\\ The thickness dependence of the effect shows that the extrapolated multiplicity in the peak in a very thin crystal tends to unity. The high energy radiation peak emitted by axially channeled electrons in a thick crystal is then interpreted by the radiation cooling mechanism. \\\\ The extrapolation to zero thickness of these results will allow us to extract from the data the single $\\gamma$ radiation spectrum. The comparison o...

  1. The Upgrade of the ATLAS Electron and Photon Triggers for LHC Run 2 and their Performance

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00220717; The ATLAS collaboration

    2016-01-01

    Electron and photon triggers covering transverse energies from 5 GeV to several TeV are essential for signal selection in a wide variety of ATLAS physics analyses to study Standard Model processes and to search for new phenomena. Final states including leptons and photons had, for example, an important role in the discovery and measurement of the Higgs particle. Dedicated triggers are also used to collect data for calibration, efficiency and fake rate measurements. The ATLAS trigger system is divided in a hardware-based (Level 1) and a software based high level trigger (HLT), both of which were upgraded during the long shutdown of the LHC in preparation for data taking at $\\sqrt{s}$ = 13TeV. The increasing luminosity and more challenging pile-up conditions as well as the planned higher center-of-mass energy demanded the optimisation of the trigger selections at each level, to control the rates and keep efficiencies high. To improve the performance multivariate analysis techniques are introduced at the HLT. Th...

  2. The Upgrade of the ATLAS Electron and Photon Triggers towards LHC Run 2 and their Performance

    CERN Document Server

    INSPIRE-00115001

    2015-01-01

    Electron and photon triggers covering transverse energies from 5 GeV to several TeV are essential for signal selection in a wide variety of ATLAS physics analyses to study Standard Model processes and to search for new phenomena. Final states including leptons and photons had, for example, an important role in the discovery and measurement of the Higgs particle. Dedicated triggers are also used to collect data for calibration, efficiency and fake rate measurements. The ATLAS trigger system is divided in a hardware-based (Level 1) and a software based High-Level Trigger (HLT), both of which were upgraded during the long shutdown of the LHC in preparation for data taking in 2015. The increasing luminosity and more chal- lenging pile-up conditions as well as the higher center-of-mass energy demanded the optimisation of the trigger selections at each level, to control the rates and keep efficiencies high. To improve the performance, multivariate analysis techniques were introduced at the HLT. The evolution of the...

  3. SU-E-T-278: Study of MAGIC-F Gel and PENELOPE Code Simulation Response for Clinical Electron Beams.

    Science.gov (United States)

    Pianoschi, T; Alva-Sánchez, M; Santanna, M; César, D; Nicolucci, P

    2012-06-01

    To evaluate the response of MAGIC-f gel through dose response curves, percentage depth dose (PDD) and beam profile for clinical electron beams. Glass tubes (Vacutainer ®), with 6 cm length and 0.5 cm radius, with MAGIC-f were positioned inside a water phantom to study the gel response with doses from 0.5 Gy to 20 Gy in electron beams of 6, 9 e 12 MeV. Glass tubes of 20 cm length and 1 cm radius and PMMA phantoms of 10 × 5 × 5 cm 3 were used to PDD and beam profiles determinations, respectively, with a maximum dose of 2 Gy to the gel. The samples were analyzed through magnetic resonance imaging (MRI) with a 3 T tomography using a head coil, multiple spin echo sequence with 16 echos, TE 15ms and TR 4000ms. The MAGIC-f response was simulated with PENELOPE Monte Carlo code in the same geometry used in the irradiations. The results obtained with MAGIC-f and PENELOPE were compared with clinical data. Calibration curves for MAGIC-f showed a linear behavior, with correlation coefficient of 0.99, for all energies. The PDD and beam profile curves obtained with MAGIC-f presented differences lower than 1.5% and 3.0%, respectively, when compared to clinical data. Results obtained by PENELOPE and clinical data showed differences up to 1.0% and 1.5%, respectively, for PDD and profile curves. The dosimetric parameters for electron beams obtained experimentally with MAGIC-f and with PENELOPE code showed similar results to the clinical data. From the results it can be inferred that MAGIC-f can be used as a complementary dosimetric tool for electron beams due to its characteristics of high spatial resolution and the ability to construct tridimensional dose distributions. Also PENELOPE can be used to study MAGIC-f gel response in electron beams. © 2012 American Association of Physicists in Medicine.

  4. Sensors, nano-electronics and photonics for the Army of 2030 and beyond

    Science.gov (United States)

    Perconti, Philip; Alberts, W. C. K.; Bajaj, Jagmohan; Schuster, Jonathan; Reed, Meredith

    2016-02-01

    The US Army's future operating concept will rely heavily on sensors, nano-electronics and photonics technologies to rapidly develop situational understanding in challenging and complex environments. Recent technology breakthroughs in integrated 3D multiscale semiconductor modeling (from atoms-to-sensors), combined with ARL's Open Campus business model for collaborative research provide a unique opportunity to accelerate the adoption of new technology for reduced size, weight, power, and cost of Army equipment. This paper presents recent research efforts on multi-scale modeling at the US Army Research Laboratory (ARL) and proposes the establishment of a modeling consortium or center for semiconductor materials modeling. ARL's proposed Center for Semiconductor Materials Modeling brings together government, academia, and industry in a collaborative fashion to continuously push semiconductor research forward for the mutual benefit of all Army partners.

  5. Color graphics display of low-high energy electron-photon transport using EGS4

    International Nuclear Information System (INIS)

    Kloepping, R.J.; Huntzinger, C.J.; Benson, E.; Nelson, W.R.

    1988-01-01

    Visual presentations are widely accepted and are a dynamic tool in education. The technique of visual presentations of Monte Carlo simulated interaction and transport using the EGS4 code system via SLAC Unified Graphics, connected to an IBM-5080 high resolution color monitor, has been previously demonstrated. EGS was originally developed by the Stanford Linear Accelerator Center (SLAC) and the High Energy Physics Laboratory (HEPL) at Stanford University as an analytical tool for engineering and physics. The EGS4 version released in 1985 is capable of simulating radiation transport from several TeV down to 1 KeV (photons) and 10 KeV (electrons and positrons). EGS can not only transport monoenergetic particles, but also particles generated from an energy distribution. This paper demonstrates the graphics capability as a teaching tool. The EGS code has been thoroughly verified by comparison with experiment and theory

  6. Universal I/O board for the laser-electron photons experiments at SPring-8

    International Nuclear Information System (INIS)

    Sugaya, Y.; Nomachi, M.

    1999-01-01

    A data acquisition system on the basis of network technologies has been developed for experiments using high-energy photons from backward-Compton scattering between laser lights and 8 GeV electrons at SPring-8. A universal I/O VME-board (UIO) is designed as a buffer-sequencer module with a reconfigurable logic circuit and a 1 Mbyte memory. The UIO is applied as a high-speed module for flexible data readout and buffering. Data from the various detectors are transferred from the UIO to a VME CPU-board in the common format. Altera Hardware Description Language is used to read data from a fast encoding and readout ADC (FERA) system for TOF counters and Cherenkov counters

  7. Triggering on electrons and photons with the CMS experiment at the LHC

    CERN Document Server

    Zabi, Alexandre

    2012-01-01

    (CMS) experiment implements a sophisticated two-level online selection system that achieves a rejection factor of nearly 10e6. The first level (L1) is based on coarse information coming from the calorimeters and the muon detectors while the High-Level Trigger (HLT) combines fine-grain information from all sub-detectors. In this intense hadronic environment, the L1 electron/photon trigger provides a powerful tool to select interesting events. It is based upon information from the Electromagnetic Calorimeter (ECAL), a high-resolution detector comprising 75848 lead tungstate (PbWO4) crystals in a "barrel" and two "endcaps". The performance as well as the optimization of the ele...

  8. Sol-gel synthesis and crystallization kinetics of dysprosium-titanate Dy2Ti2O7 for photonic applications

    Czech Academy of Sciences Publication Activity Database

    Mrázek, Jan; Potel, M.; Buršík, Jiří; Mráček, A.; Kallistová, Anna; Jonášová, Šárka; Boháček, Jan; Kašík, Ivan

    2015-01-01

    Roč. 168, November (2015), s. 159-167 ISSN 0254-0584 Institutional support: RVO:67985882 ; RVO:68081723 ; RVO:67985831 Keywords : Ceramics * Inorganic compounds * Optical materials Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering; JG - Metallurgy (UFM-A); CB - Analytical Chemistry , Separation (GLU-S) Impact factor: 2.101, year: 2015

  9. Multivariate analyses of locoregional recurrences and skin complications after postmastectomy radiotherapy using electrons or photons.

    Science.gov (United States)

    Huang, Eng-Yen; Chen, Hui-Chun; Sun, Li-Min; Fang, Fu-Min; Hsu, Hsuan-Chih; Hsiung, Ching-Yeh; Huang, Yu-Jie; Wang, Chang-Yu; Wang, Chong-Jong

    2006-08-01

    We retrospectively analyzed factors of locoregional (LR) recurrence and skin complications in patients after postmastectomy radiotherapy (PMRT). From January 1988 to December 1999, a total of 246 women with Stage II and III breast cancer received PMRT. Doses of 46 to 52.2 Gy/23 to 29 fractions were delivered to the chest wall (CW) and peripheral lymphatic drainage with 12 to 15 MeV single-portal electrons or 6MV photons. Of the patients, 84 patients received an additional 6 to 20 Gy boost to the surgical scar using 9 MeV electrons. We used the Cox regression model for multivariate analyses of CW, supraclavicular nodes (SCN), and LR recurrence. N3 stage (positive nodes >9) (p = 0.003) and diabetes (p = 0.004) were independent factors of CW recurrence. Analysis of ipsilateral SCN recurrence showed that N3 stage (p Analysis of skin telangiectasia revealed that electrons (p skin telangiectasia. In patients in whom the number of positive axillary nodes is >9, more aggressive treatment may be considered for better locoregional control.

  10. Configurable Electronics with Low Noise and 14-bit Dynamic Range for Photodiode-based Photon Detectors

    CERN Document Server

    Müller, H; Yin, Z; Zhou, D; Cao, X; Li, Q; Liu, Y; Zou, F; Skaali, B; Awes, T C

    2006-01-01

    We describe the principles and measured performance characteristics of custom configurable 32-channel shaper/digitizer Front End Electronics (FEE) cards with 14-bit dynamic range for use with gain-adjustable photon detectors. The electronics has been designed for the PHOS calorimeter of ALICE with avalanche photodiode (APD) readout operated at -25 C ambient temperature and a signal shaping time of $1 {\\mu}s$. The electronics has also been adopted by the EMCal detector of ALICE with the same APD readout, but operated at an ambient temperature of +20 C and with a shaping time of 100ns. The CR-RC2 signal shapers on the FEE cards are implemented in discrete logic on a 10-layer board with two shaper sections for each input channel. The two shaper sections with gain ratio of 16:1 are digitized by 10-bit ADCs and provide an effective dynamic range of 14 bits. Gain adjustment for each individual APD is available through 32 bias voltage control registers of 10-bit range. The fixed gains and shaping times of the pole-z...

  11. ELECTRON MICROSCOPIC INVESTIGATION OF YTTRIUM ALUMINUM GARNET POWDERS Y3AL5O12, SYNTHESIZED BY SOL–GEL METHOD

    OpenAIRE

    A. E. Baranchikov; V. A. Maslov; S. V. Shcherbakov; V. A. Usachyov; N. E. Kononenko; P. P. Fedorov; K. V. Dukelskiy

    2015-01-01

    Subject of Study. The paper presents results of characterization for neodymium doped yttrium aluminum garnet nanopowders - YAG:Nd3+ by the method of scanning electronic microscopy. Method. Synthesis of YAG:Nd3+ was carried out by sol-gel method from nitrate or acetate - nitrate solutions with addition of some organic compounds and ammonia as well. Such substances were used as the source ones: oxides of neodymium and yttrium with the content of the basic substance equal to 99.999 %; organic co...

  12. Interaction of electron beams with optical nanostructures and metamaterials: from coherent photon sources towards shaping the wave function

    Science.gov (United States)

    Talebi, Nahid

    2017-10-01

    Investigating the interaction of electron beams with materials and light has been a field of research for more than a century. The field was advanced theoretically by the rise of quantum mechanics and technically by the introduction of electron microscopes and accelerators. It is possible nowadays to uncover a multitude of information from electron-induced excitations in matter by means of advanced techniques like holography, tomography, and, most recently, photon-induced near-field electron microscopy. The question is whether the interaction can be controlled in an even, more efficient way in order to unravel important questions like modal decomposition of the electron-induced polarization by performing experiments with better spatial, temporal, and energy resolutions. This review discusses recent advances in controlling electron and light interactions at the nanoscale. Theoretical and numerical aspects of the interaction of electrons with nanostructures and metamaterials will be discussed with the aim of understanding the mechanisms of radiation in the interaction of electrons with even more sophisticated structures. Based on these mechanisms of radiation, state-of-the art and novel electron-driven few-photon sources will be discussed. Applications of such sources to gain an understanding of quantum optical effects and also to perform spectral interferometry with electron microscopes will be covered. In an inverse approach, as in the case of the inverse Smith-Purcell effect, laser-induced excitations of nanostructures can cause electron beams traveling in the near-field of such structures to accelerate, provided a synchronization criterion is satisfied. This effect is the basis for linear dielectric and metallic electron accelerators. Moreover, acceleration is accompanied by bunching of the electrons. When single electrons are considered, an efficient design of nanostructures can lead to the shaping of the electron wave function travelling adjacent to them, for

  13. Electron heating by photon-assisted tunneling in niobium terahertz mixers with integrated niobium titanium nitride striplines

    NARCIS (Netherlands)

    Leone, B; Gao, [No Value; Klapwijk, TM; Jackson, BD; Laauwen, WM; de Lange, G

    2001-01-01

    We describe the gap voltage depression and current-voltage (I-V) characteristics in pumped niobium superconductor-insulator-superconductor junction with niobium titanium nitride tuning stripline by introducing an electron heating power contribution resulting from the photon-assisted tunneling

  14. Comparison of analytical and Monte Carlo calculations of multi-photon effects in bremsstrahlung emission by high-energy electrons

    DEFF Research Database (Denmark)

    Mangiarotti, Alessio; Sona, Pietro; Ballestrero, Sergio

    2012-01-01

    Approximate analytical calculations of multi-photon effects in the spectrum of total radiated energy by high-energy electrons crossing thin targets are compared to the results of Monte Carlo type simulations. The limits of validity of the analytical expressions found in the literature are establi...

  15. Anisotropy in angular distributions of 238U fission fragments by photons, produced in high energy electron interaction with Si monocrystal

    International Nuclear Information System (INIS)

    Kasilov, V.I.; Lapin, N.N.

    1981-01-01

    An enhancement is detected under the angle of 90 deg in the fission fragment yield from 238 U nuclei produced by photons emitted by high-energy electrons passing through a silicon monocrystal. The results enable one to select the most optimal conditions to obtain maximal yields of nuclear particles [ru

  16. A simplified spherical harmonic method for coupled electron-photon transport calculations

    International Nuclear Information System (INIS)

    Josef, J.A.

    1996-12-01

    In this thesis we have developed a simplified spherical harmonic method (SP N method) and associated efficient solution techniques for 2-D multigroup electron-photon transport calculations. The SP N method has never before been applied to charged-particle transport. We have performed a first time Fourier analysis of the source iteration scheme and the P 1 diffusion synthetic acceleration (DSA) scheme applied to the 2-D SP N equations. Our theoretical analyses indicate that the source iteration and P 1 DSA schemes are as effective for the 2-D SP N equations as for the 1-D S N equations. Previous analyses have indicated that the P 1 DSA scheme is unstable (with sufficiently forward-peaked scattering and sufficiently small absorption) for the 2-D S N equations, yet is very effective for the 1-D S N equations. In addition, we have applied an angular multigrid acceleration scheme, and computationally demonstrated that it performs as well for the 2-D SP N equations as for the 1-D S N equations. It has previously been shown for 1-D S N calculations that this scheme is much more effective than the DSA scheme when scattering is highly forward-peaked. We have investigated the applicability of the SP N approximation to two different physical classes of problems: satellite electronics shielding from geomagnetically trapped electrons, and electron beam problems. In the space shielding study, the SP N method produced solutions that are accurate within 10% of the benchmark Monte Carlo solutions, and often orders of magnitude faster than Monte Carlo. We have successfully modeled quasi-void problems and have obtained excellent agreement with Monte Carlo. We have observed that the SP N method appears to be too diffusive an approximation for beam problems. This result, however, is in agreement with theoretical expectations

  17. Effective atomic numbers and electron densities of bioactive glasses for photon interaction

    Science.gov (United States)

    Shantappa, Anil; Hanagodimath, S. M.

    2015-08-01

    This work was carried out to study the nature of mass attenuation coefficient of bioactive glasses for gamma rays. Bioactive glasses are a group of synthetic silica-based bioactive materials with unique bone bonding properties. In the present study, we have calculated the effective atomic number, electron density for photon interaction of some selected bioactive glasses viz., SiO2-Na2O, SiO2-Na2O-CaO and SiO2-Na2O-P2O5 in the energy range 1 keV to 100 MeV. We have also computed the single valued effective atomic number by using XMuDat program. It is observed that variation in effective atomic number (ZPI, eff) depends also upon the weight fractions of selected bioactive glasses and range of atomic numbers of the elements. The results shown here on effective atomic number, electron density will be more useful in the medical dosimetry for the calculation of absorbed dose and dose rate.

  18. Two-photon laser spectroscopy of antiprotonic helium and the antiproton-to-electron mass ratio

    CERN Document Server

    Hori, Masaki; Barna, Daniel; Andreas Dax,; Hayano, Ryugo; Friedreich, Susanne; Juhász, Bertalan; Pask, Thomas; Widmann, Eberhard; Horváth, Dezső; Venturelli, Luca; Zurlo, Nicola; 10.1038/nature10260

    2013-01-01

    Physical laws are believed to be invariant under the combined transformations of charge, parity and time reversal (CPT symmetry). This implies that an antimatter particle has exactly the same mass and absolute value of charge as its particle counterpart. Metastable antiprotonic helium ($\\bar{p}He^+$) is a three-body atom2 consisting of a normal helium nucleus, an electron in its ground state and an antiproton ($\\bar{p}$) occupying a Rydberg state with high principal and angular momentum quantum numbers, respectively n and l, such that n ≈ l + 1 ≈ 38. These atoms are amenable to precision laser spectroscopy, the results of which can in principle be used to determine the antiproton-to-electron mass ratio and to constrain the equality between the antiproton and proton charges and masses. Here we report two-photon spectroscopy of antiprotonic helium, in which $\\bar{p}^{3}He^{+}$ and $\\bar{p}^{4}He^{+}$ isotopes are irradiated by two counter-propagating laser beams. This excites nonlinear, two-phot...

  19. Multivariate analyses of locoregional recurrences and skin complications after postmastectomy radiotherapy using electrons or photons

    International Nuclear Information System (INIS)

    Huang, E.-Y.; Chen, H.-C.; Sun, L.-M.; Fang, F.-M.; Hsu, H.-C.; Hsiung, C.-Y.; Huang, Y.-J.; Wang, C.-Y.; Wang, C.-J.

    2006-01-01

    Purpose: We retrospectively analyzed factors of locoregional (LR) recurrence and skin complications in patients after postmastectomy radiotherapy (PMRT). Methods and Materials: From January 1988 to December 1999, a total of 246 women with Stage II and III breast cancer received PMRT. Doses of 46 to 52.2 Gy/23 to 29 fractions were delivered to the chest wall (CW) and peripheral lymphatic drainage with 12 to 15 MeV single-portal electrons or 6MV photons. Of the patients, 84 patients received an additional 6 to 20 Gy boost to the surgical scar using 9 MeV electrons. We used the Cox regression model for multivariate analyses of CW, supraclavicular nodes (SCN), and LR recurrence. Results: N3 stage (positive nodes >9) (p = 0.003) and diabetes (p = 0.004) were independent factors of CW recurrence. Analysis of ipsilateral SCN recurrence showed that N3 stage (p 9, more aggressive treatment may be considered for better locoregional control

  20. Electron correlations and two-photon states in polycyclic aromatic hydrocarbon molecules: A peculiar role of geometry

    International Nuclear Information System (INIS)

    Aryanpour, Karan; Shukla, Alok; Mazumdar, Sumit

    2014-01-01

    We present numerical studies of one- and two-photon excited states ordering in a number of polycyclic aromatic hydrocarbon molecules: coronene, hexa-peri-hexabenzocoronene, and circumcoronene, all possessing D 6h point group symmetry versus ovalene with D 2h symmetry, within the Pariser-Parr-Pople model of interacting π-electrons. The calculated energies of the two-photon states as well as their relative two-photon absorption cross-sections within the interacting model are qualitatively different from single-particle descriptions. More remarkably, a peculiar role of molecular geometry is found. The consequence of electron correlations is far stronger for ovalene, where the lowest spin-singlet two-photon state is a quantum superposition of pairs of lowest spin triplet states, as in the linear polyenes. The same is not true for D 6h group hydrocarbons. Our work indicates significant covalent character, in valence bond language, of the ground state, the lowest spin triplet state and a few of the lowest two-photon states in D 2h ovalene but not in those with D 6h symmetry

  1. Electron correlations and two-photon states in polycyclic aromatic hydrocarbon molecules: A peculiar role of geometry

    Energy Technology Data Exchange (ETDEWEB)

    Aryanpour, Karan [Department of Physics, University of Arizona, Tucson, Arizona 85721 (United States); Shukla, Alok [Department of Physics, Indian Institute of Technology, Powai, Mumbai 400076 (India); Mazumdar, Sumit [Department of Physics, University of Arizona, Tucson, Arizona 85721 (United States); College of Optical Sciences, University of Arizona, Tucson, Arizona 85721 (United States)

    2014-03-14

    We present numerical studies of one- and two-photon excited states ordering in a number of polycyclic aromatic hydrocarbon molecules: coronene, hexa-peri-hexabenzocoronene, and circumcoronene, all possessing D{sub 6h} point group symmetry versus ovalene with D{sub 2h} symmetry, within the Pariser-Parr-Pople model of interacting π-electrons. The calculated energies of the two-photon states as well as their relative two-photon absorption cross-sections within the interacting model are qualitatively different from single-particle descriptions. More remarkably, a peculiar role of molecular geometry is found. The consequence of electron correlations is far stronger for ovalene, where the lowest spin-singlet two-photon state is a quantum superposition of pairs of lowest spin triplet states, as in the linear polyenes. The same is not true for D{sub 6h} group hydrocarbons. Our work indicates significant covalent character, in valence bond language, of the ground state, the lowest spin triplet state and a few of the lowest two-photon states in D{sub 2h} ovalene but not in those with D{sub 6h} symmetry.

  2. Electron correlations and two-photon states in polycyclic aromatic hydrocarbon molecules: a peculiar role of geometry.

    Science.gov (United States)

    Aryanpour, Karan; Shukla, Alok; Mazumdar, Sumit

    2014-03-14

    We present numerical studies of one- and two-photon excited states ordering in a number of polycyclic aromatic hydrocarbon molecules: coronene, hexa-peri-hexabenzocoronene, and circumcoronene, all possessing D(6h) point group symmetry versus ovalene with D(2h) symmetry, within the Pariser-Parr-Pople model of interacting π-electrons. The calculated energies of the two-photon states as well as their relative two-photon absorption cross-sections within the interacting model are qualitatively different from single-particle descriptions. More remarkably, a peculiar role of molecular geometry is found. The consequence of electron correlations is far stronger for ovalene, where the lowest spin-singlet two-photon state is a quantum superposition of pairs of lowest spin triplet states, as in the linear polyenes. The same is not true for D(6h) group hydrocarbons. Our work indicates significant covalent character, in valence bond language, of the ground state, the lowest spin triplet state and a few of the lowest two-photon states in D(2h) ovalene but not in those with D(6h) symmetry.

  3. Microwave photonics

    CERN Document Server

    Lee, Chi H

    2006-01-01

    Wireless, optical, and electronic networks continue to converge, prompting heavy research into the interface between microwave electronics, ultrafast optics, and photonic technologies. New developments arrive nearly as fast as the photons under investigation, and their commercial impact depends on the ability to stay abreast of new findings, techniques, and technologies. Presenting a broad yet in-depth survey, Microwave Photonics examines the major advances that are affecting new applications in this rapidly expanding field.This book reviews important achievements made in microwave photonics o

  4. Bowel sparing in pediatric cranio-spinal radiotherapy: a comparison of combined electron and photon and helical TomoTherapy techniques to a standard photon method

    International Nuclear Information System (INIS)

    Harron, Elizabeth; Lewis, Joanne

    2012-01-01

    The aim of this study was to compare the dose to organs at risk (OARs) from different craniospinal radiotherapy treatment approaches available at the Northern Centre for Cancer Care (NCCC), with a particular emphasis on sparing the bowel. Method: Treatment plans were produced for a pediatric medulloblastoma patient with inflammatory bowel disease using 3D conformal 6-MV photons (3DCP), combined 3D 6-MV photons and 18-MeV electrons (3DPE), and helical photon TomoTherapy (HT). The 3DPE plan was a modification of the standard 3DCP technique, using electrons to treat the spine inferior to the level of the diaphragm. The plans were compared in terms of the dose-volume data to OARs and the nontumor integral dose. Results: The 3DPE plan was found to give the lowest dose to the bowel and the lowest nontumor integral dose of the 3 techniques. However, the coverage of the spine planning target volume (PTV) was least homogeneous using this technique, with only 74.6% of the PTV covered by 95% of the prescribed dose. HT was able to achieve the best coverage of the PTVs (99.0% of the whole-brain PTV and 93.1% of the spine PTV received 95% of the prescribed dose), but delivered a significantly higher integral dose. HT was able to spare the heart, thyroid, and eyes better than the linac-based techniques, but other OARs received a higher dose. Conclusions: Use of electrons was the best method for reducing the dose to the bowel and the integral dose, at the expense of compromised spine PTV coverage. For some patients, HT may be a viable method of improving dose homogeneity and reducing selected OAR doses.

  5. A hybrid electron and photon IMRT planning technique that lowers normal tissue integral patient dose using standard hardware.

    Science.gov (United States)

    Rosca, Florin

    2012-06-01

    To present a mixed electron and photon IMRT planning technique using electron beams with an energy range of 6-22 MeV and standard hardware that minimizes integral dose to patients for targets as deep as 7.5 cm. Ten brain cases, two lung, a thyroid, an abdominal, and a parotid case were planned using two planning techniques: a photon-only IMRT (IMRT) versus a mixed modality treatment (E+IMRT) that includes an enface electron beam and a photon IMRT portion that ensures a uniform target coverage. The electron beam is delivered using a regular cutout placed in an electron cone. The electron energy was chosen to provide a good trade-off between minimizing integral dose and generating a uniform, deliverable plan. The authors choose electron energies that cover the deepest part of PTV with the 65%-70% isodose line. The normal tissue integral dose, the dose for ring structures around the PTV, and the volumes of the 75%, 50%, and 25% isosurfaces were used to compare the dose distributions generated by the two planning techniques. The normal tissue integral dose was lowered by about 20% by the E+IMRT plans compared to the photon-only IMRT ones for most studied cases. With the exception of lungs, the dose reduction associated to the E+IMRT plans was more pronounced further away from the target. The average dose ratio delivered to the 0-2 cm and the 2-4 cm ring structures for brain patients for the two planning techniques were 89.6% and 70.8%, respectively. The enhanced dose sparing away from the target for the brain patients can also be observed in the ratio of the 75%, 50%, and 25% isodose line volumes for the two techniques, which decreases from 85.5% to 72.6% and further to 65.1%, respectively. For lungs, the lateral electron beams used in the E+IMRT plans were perpendicular to the mostly anterior/posterior photon beams, generating much more conformal plans. The authors proved that even using the existing electron delivery hardware, a mixed electron/photon planning

  6. Combined photon-electron beams in the treatment of the supraclavicular lymph nodes in breast cancer: A novel technique that achieves adequate coverage while reducing lung dose.

    Science.gov (United States)

    Salem, Ahmed; Mohamad, Issa; Dayyat, Abdulmajeed; Kanaa'n, Haitham; Sarhan, Nasim; Roujob, Ibrahim; Salem, Abdel-Fattah; Afifi, Shatha; Jaradat, Imad; Mubiden, Rasmi; Almousa, Abdelateif

    2015-01-01

    Radiation pneumonitis is a well-documented side effect of radiation therapy for breast cancer. The purpose of this study was to compare combined photon-electron, photon-only, and electron-only plans in the radiation treatment of the supraclavicular lymph nodes. In total, 13 patients requiring chest wall and supraclavicular nodal irradiation were planned retrospectively using combined photon-electron, photon-only, and electron-only supraclavicular beams. A dose of 50Gy over 25 fractions was prescribed. Chest wall irradiation parameters were fixed for all plans. The goal of this planning effort was to cover 95% of the supraclavicular clinical target volume (CTV) with 95% of the prescribed dose and to minimize the volume receiving ≥ 105% of the dose. Comparative end points were supraclavicular CTV coverage (volume covered by the 95% isodose line), hotspot volume, maximum radiation dose, contralateral breast dose, mean total lung dose, total lung volume percentage receiving at least 20 Gy (V(20 Gy)), heart volume percentage receiving at least 25 Gy (V(25 Gy)). Electron and photon energies ranged from 8 to 18 MeV and 4 to 6 MV, respectively. The ratio of photon-to-electron fractions in combined beams ranged from 5:20 to 15:10. Supraclavicular nodal coverage was highest in photon-only (mean = 96.2 ± 3.5%) followed closely by combined photon-electron (mean = 94.2 ± 2.5%) and lowest in electron-only plans (mean = 81.7 ± 14.8%, p dose was higher in the electron-only (mean = 69.7 ± 56.1 cm(3)) as opposed to combined photon-electron (mean = 50.8 ± 40.9 cm(3)) and photon-only beams (mean = 32.2 ± 28.1 cm(3), p = 0.114). Heart V(25 Gy) was not statistically different among the plans (p = 0.999). Total lung V(20 Gy) was lowest in electron-only (mean = 10.9 ± 2.3%) followed by combined photon-electron (mean = 13.8 ± 2.3%) and highest in photon-only plans (mean = 16.2 ± 3%, p electron-only beams, in terms of decreasing lung dose, is set back by the dosimetric hotspots

  7. A study of Rhizophora spp wood phantom for dosimetric purposes using high-energy photon and electron beams

    Energy Technology Data Exchange (ETDEWEB)

    Banjade, D.P. E-mail: dpbl4007@stud.usm.my; Tajuddin, A.A.; Shukri, A

    2001-09-01

    Previous scattering and depth-dose investigations involving use of the Malaysian hardwood Rhizophora spp have shown this medium to produce good agreement with measurements made in water. Present study extends the comparison, now including measurements of percentage depth-dose made for photons at 6 MV and 5 and 12 MeV electron beams. For the 6 MV photon and 5 MeV electron beams, discrepancies between percentage depth-dose for Rhizophora spp and water, at all depths, are found to be within 2.6 and 2.4% respectively. At 12 MeV electron energies, measured percentage depth-doses in Rhizophora spp beyond 3.5 cm depth are found to be in significant discord with those for water. The absorbed dose in water measured in Rhizophora spp at d{sub max} for all three beams produces discrepancies of no more than 1.1% when compared with measurements made in water.

  8. PREFACE: XXVIII International Conference on Photonic, Electronic and Atomic Collisions (ICPEAC 2013)

    Science.gov (United States)

    Xiao, Guoqing; Cai, Xiaohong; Ding, Dajun; Ma, Xinwen; Zhao, Yongtao

    2014-04-01

    The 28th International Conference on Photonic, Electronic and Atomic Collisions (XXVIII ICPEAC) was held by the Institute of Modern Physics, Chinese Academy of Sciences (IMP) on 24-30 July, 2013 in Lanzhou, China. The 444 conference participants came from 37 countries and/or regions. Five plenary lectures, more than 80 progress reports and special reports had been arranged according to the decision of the ICPEAC International General Committee. Meanwhile, more than 650 abstracts were selected as poster presentations. Before the conference, three highly distinguished scientists, Professor Joachim Burgdöorfer, Professor Hossein Sadeghpour and Professor Yasunori Yamazaki, presented tutorial lectures with the support of the IMP Branch of Youth Innovation Promotion Association, CAS (IMP-YIPA). During the conference, Professor Jianwei Pan from University of Sciences and Technology in China presented an enlightening public lecture on quantum communication. Furthermore, 2013 IUPAP Young Scientist Prize was awarded to Dr T Jahnke from Johann Wolfgang Goethe University of Germany. The Sheldon Datz Prize for an Outstanding Young Scientist Attending ICPEAC was awarded to Dr Diogo Almeida from University of Fribourg of Switzerland. As a biannual academic conference, ICPEAC is one of the most important international conferences on atomic and molecular physics. The topic of the conference covers the recent progresses in photonic, electronic, atomic, ionic, molecular, cluster collisions with matter. With a history back to 1958, ICPEAC came to China for the very first time. IMP has been preparing the conference six years before, ever since the ICPEAC International General Committee made the decision to hold the XXVIII ICPEAC in Lanzhou. This proceedings includes the papers of the two plenary lectures, 40 progress reports, 17 special reports and 337 posters, which were reviewed and revised according to the comments of the referees. The Local Organizing Committee would like to

  9. Investigation of electron-loss and photon scattering correction factors for FAC-IR-300 ionization chamber

    Science.gov (United States)

    Mohammadi, S. M.; Tavakoli-Anbaran, H.; Zeinali, H. Z.

    2017-02-01

    The parallel-plate free-air ionization chamber termed FAC-IR-300 was designed at the Atomic Energy Organization of Iran, AEOI. This chamber is used for low and medium X-ray dosimetry on the primary standard level. In order to evaluate the air-kerma, some correction factors such as electron-loss correction factor (ke) and photon scattering correction factor (ksc) are needed. ke factor corrects the charge loss from the collecting volume and ksc factor corrects the scattering of photons into collecting volume. In this work ke and ksc were estimated by Monte Carlo simulation. These correction factors are calculated for mono-energy photon. As a result of the simulation data, the ke and ksc values for FAC-IR-300 ionization chamber are 1.0704 and 0.9982, respectively.

  10. Bibliography of electron and photon cross sections with atoms and molecules published in the 20th century. Argon

    International Nuclear Information System (INIS)

    Hayashi, Makoto

    2003-01-01

    A bibliography of original and review reports of experiments or theories of electron and photon cross sections and also electron swarm data are presented for atomic or molecular species with specified targets. These works covered 17 atoms and 51 molecules. The present bibliography is only for argon (Ar). About 1,960 papers were compiled. A comprehensive author index is included. The bibliography covers the period 1921 through 2000 for Ar. Finally, author's recommended Ar electron collision cross section set is given in numerical tables. (author)

  11. Bibliography of electron and photon cross sections with atoms and molecules published in the 20th century. Sulphur hexafluoride

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, Makoto [Gaseous Electronics Institute, Nagoya, Aichi (Japan)

    2003-05-01

    A bibliography of original and review reports of experiments or theories of electron and photon cross sections and also electron swarm data are presented for atomic or molecular species with specified targets. These works covered 17 atoms and 51 molecules. The present bibliography is only for sulphur hexafluoride (SF{sub 6}). About 920 papers were compiled. A comprehensive author index is included. The bibliography covers the period 1934 through 2000 for SF{sub 6}. Finally, author's comments for SF{sub 6} electron collision cross section are given. (author)

  12. Bibliography of electron and photon cross sections with atoms and molecules published in the 20th century. Carbon dioxide

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, Makoto [Gaseous Electronics Institute, Nagoya, Aichi (Japan)

    2003-04-01

    A bibliography of original and review reports of experiments or theories of electron and photon cross sections and also electron swarm data are presented for atomic or molecular species with specified targets. These works covered 17 atoms and 51 molecules. The present bibliography is only for carbon dioxide (CO{sub 2}). About 1,240 papers were compiled. A comprehensive author index is included. The bibliography covers the period 1901 through 2000 for CO{sub 2}. Finally, author's comments for CO{sub 2} electron collision cross sections are given. (author)

  13. Bibliography of electron and photon cross sections with atoms and molecules published in the 20th century. Nitrogen molecule

    International Nuclear Information System (INIS)

    Hayashi, Makoto

    2003-06-01

    A bibliography of original and review reports of experiments or theories of electron and photon cross sections and also electron swarm data are presented for atomic or molecular species with specified targets. These works covered 17 atoms and 51 molecules. The present bibliography is only for nitrogen molecule (N 2 ). About 2240 papers were compiled. A comprehensive author index is include. The bibliography covers the period 1906 through 2000 for N 2 . Finally, author's comments for N 2 electron collision cross section are given. (author)

  14. Bibliography of electron and photon cross sections with atoms and molecules published in the 20th century. Sulphur hexafluoride

    International Nuclear Information System (INIS)

    Hayashi, Makoto

    2003-05-01

    A bibliography of original and review reports of experiments or theories of electron and photon cross sections and also electron swarm data are presented for atomic or molecular species with specified targets. These works covered 17 atoms and 51 molecules. The present bibliography is only for sulphur hexafluoride (SF 6 ). About 920 papers were compiled. A comprehensive author index is included. The bibliography covers the period 1934 through 2000 for SF 6 . Finally, author's comments for SF 6 electron collision cross section are given. (author)

  15. Bibliography of electron and photon cross sections with atoms and molecules published in the 20th century. Carbon dioxide

    International Nuclear Information System (INIS)

    Hayashi, Makoto

    2003-04-01

    A bibliography of original and review reports of experiments or theories of electron and photon cross sections and also electron swarm data are presented for atomic or molecular species with specified targets. These works covered 17 atoms and 51 molecules. The present bibliography is only for carbon dioxide (CO 2 ). About 1,240 papers were compiled. A comprehensive author index is included. The bibliography covers the period 1901 through 2000 for CO 2 . Finally, author's comments for CO 2 electron collision cross sections are given. (author)

  16. Bibliography of electron and photon cross sections with atoms and molecules published in the 20th century. Argon

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, Makoto [Gaseous Electronics Institute, Nagoya, Aichi (Japan)

    2003-01-01

    A bibliography of original and review reports of experiments or theories of electron and photon cross sections and also electron swarm data are presented for atomic or molecular species with specified targets. These works covered 17 atoms and 51 molecules. The present bibliography is only for argon (Ar). About 1,960 papers were compiled. A comprehensive author index is included. The bibliography covers the period 1921 through 2000 for Ar. Finally, author's recommended Ar electron collision cross section set is given in numerical tables. (author)

  17. Bibliography of electron and photon cross sections with atoms and molecules published in the 20th century. Halogen molecules

    International Nuclear Information System (INIS)

    Hayashi, Makoto

    2003-12-01

    A bibliographies of original and review reports of experiments or theories of electron and photon cross sections and also electron swarm data are presented for atomic or molecular species with specified targets. These works covered 17 atoms and 51 molecules. The present bibliography is only for halogen molecules (F 2 , Cl 2 , Br 2 , I 2 ). About 190(F 2 ), 360(Cl 2 ), 140(Br 2 ) and 240(I 2 ) papers were compiled respectively. A comprehensive author indexes for each molecule are included. The bibliography covers the period 1901 through 2000 for F 2 -I 2 . Finally, author's comments for F 2 -I 2 electron collision cross sections are given. (author)

  18. Bibliography of electron and photon cross sections with atoms and molecules published in the 20th century. Hydrogen molecules

    International Nuclear Information System (INIS)

    Hayashi, Makoto

    2004-02-01

    Bibliographies of original and review reports of experiments or theories of electron and photon cross sections and also electron swarm data are presented for atomic or molecular species with specified targets. These works covered 17 atoms and 51 molecules. The present bibliography is only for hydrogen molecules (H 2 , HD, HT, D 2 , DT, T 2 ). About 2200 papers were compiled. A comprehensive author index is included. The bibliography covers the period 1901 through 2000 for H 2 . Finally, author's comments for H 2 electron collision cross sections are given. (author)

  19. Bibliography of electron and photon cross sections with atoms and molecules published in the 20th century. Ammonia and phosphine

    International Nuclear Information System (INIS)

    Hayashi, Makoto

    2004-08-01

    Bibliographies of original and review reports of experiments or theories of electron and photon cross sections and also electron swarm data are presented for atomic or molecular species with specified targets. These works covered 17 atoms and 51 molecules. The present bibliography is only for ammonia (NH 3 ) and phosphine (PH 3 ). About 820 (NH 3 ) and 190 (PH 3 ) papers were compiled respectively. Comprehensive author indexes for each molecule are included. The bibliography covers the period 1922 through 2000 for NH 3 and 1928 through 2000 for PH 3 . Finally, author's comments for NH 3 electron collision cross sections are given. (author)

  20. Bibliography of electron and photon cross sections with atoms and molecules published in the 20th century. Hydrogen halide molecules

    International Nuclear Information System (INIS)

    Hayashi, Makoto

    2004-03-01

    Bibliographies of original and review reports of experiments or theories of electron and photon cross sections and also electron swarm data are presented for atomic or molecular species with specified targets. These works covered 17 atoms and 51 molecules. The present bibliography is only for hydrogen halide molecules (HF, HCL, HBr, HI). About 330 (HF), 420 (HCl) 220 (HBr) and 150 (HI) papers were compiled respectively. Comprehensive author indexes for each molecule are included. The bibliography covers the period 1903 through 2000 for HF-HI. Finally, author's comments for HBr electron collision cross sections are given. (author)

  1. Bibliography of electron and photon cross sections with atoms and molecules published in the 20th century. Water vapour

    International Nuclear Information System (INIS)

    Hayashi, Makoto

    2003-12-01

    Bibliographies of original and review reports of experiments or theories of electron and photon cross sections and also electron swarm data are presented for atomic or molecular species with specified targets. These works covered 17 atoms and 51 molecules. The present bibliography is only for water vapour (H 2 O, D 2 O and HDO). About 1200 papers were compiled. A comprehensive author index is included. The bibliography covers the period 1915 through 2000 for H 2 O. Finally, author's comments for electron collision cross sections and photodissociation processes of H 2 O are given. (author)

  2. Level-1 trigger selection of electrons and photons with CMS for LHC Run-II.

    CERN Document Server

    AUTHOR|(CDS)2088114

    2016-01-01

    The CMS experiment has a sophisticated two-level online selection system that achieves a rejection factor of nearly $10^5$. The first, hardware-level trigger (L1) is based on coarse information coming from the calorimeters and the muon detectors while the High-Level Trigger combines fine-grain information from all subdetectors. During Run II, the LHC will increase its center of mass energy to 13 or 14 TeV, and progressively reach an instantaneous luminosity of $2\\times10^{34} \\mathrm{cm}^{-2}\\mathrm{s}^{-1}$. In order to guarantee a successful and ambitious physics programme in this intense environment, the CMS trigger and data acquisition system must be upgraded. The L1 calorimeter trigger hardware and architecture in particular has been redesigned to maintain the current thresholds even in presence of more demanding conditions (e.g., for electrons and photons) and improve the performance for the selection of $\\tau$ leptons. This design benefits from recent $\\mu$TCA technology, allowing sophisticated algorit...

  3. Study of electron pair and photon production in lead-gold collisions

    CERN Multimedia

    Ravinovich, I; Fraenkel, Z; Gnaenski, A

    2002-01-01

    This is a continuation of the NA45 experiment dedicated to the measurement of electron-positron pairs and direct photons produced in Pb-Pb collisions at SPS energies. The main goal remains as outlined in NA45. The strong enhancement of low-mass pairs, over the expected yield from hadronic sources, observed in S-Au collisions by NA45, adds considerably to the physics potential and to the interest in the measurement of these variables. \\\\\\\\The figure shows the layout of the CERES spectrometer which has been upgraded to cope with the higher multiplicities and background of central Pb-Pb collisions. The basic spectrometer remains unchanged, namely two Ring Imaging Cherenkov detectors (RICH), one situated before the other after a short superconducting double solenoid. The main elements of the upgrade are additional detectors, two silicon radial-drift chambers (instead of one in the original set-up) and a pad chamber (a large MWPC with pad readout) located behind the spectrometer. They allow real tracking and help...

  4. Signatures of the electron saddle swaps mechanism in the photon spectra following charge-exchange collisions

    Science.gov (United States)

    Otranto, Sebastian

    2014-10-01

    During the last few years, several experimental and theoretical studies have focused on state selective charge exchange processes between charged ions and alkali metals. These data are of particular importance for the tokamak nuclear fusion reactor program, since diagnostics on the plasma usually rely on charge-exchange spectroscopy. In this sense, alkali metals, have been proposed as potential alternatives to excited hydrogen/deuterium for which laboratory experiments are not feasible at present. In this talk, we present our recent work involving ion collisions with alkali metals. Oscillatory structures in the angular differential charge-exchange cross sections obtained using the MOTRIMS technique are correctly described by classical trajectory Monte Carlo simulations. These oscillations are found to originate from the number of swaps the electron undergoes around the projectile-target potential saddle before capture takes place and are very prominent at impact energies below 10 keV/amu. Moreover, cross sections of higher order of differentiability also indicate that the swaps leave distinctive signatures in the (n,l)-state selective cross sections and in the photon line emission cross sections. Oscillatory structures for the x-ray hardness ratio parameter are also predicted. In collaboration with Ronnie Hoekstra, Zernike Institute for Advanced Materials, University of Groningen and Ronald Olson, Department of Physics, Missouri University of Science and Technology.

  5. Self-adjoint angular flux equation for coupled electron-photon transport

    International Nuclear Information System (INIS)

    Liscum-Powell, J.L.; Prinja, A.K.; Morel, J.E.; Lorence, L.J. Jr.

    1999-01-01

    Recently, Morel and McGhee described an alternate second-order form of the transport equation called the self-adjoint angular flux (SAAF) equation that has the angular flux as its unknown. The SAAF formulation has all the advantages of the traditional even- and odd-parity self-adjoint equations, with the added advantages that it yields the full angular flux when it is numerically solved, it is significantly easier to implement reflective and reflective-like boundary conditions, and in the appropriate form it can be solved in void regions. The SAAF equation has the disadvantage that the angular domain is the full unit sphere, and, like the even- and odd-parity form, S n source iteration cannot be implemented using the standard sweeping algorithm. Also, problems arise in pure scattering media. Morel and McGhee demonstrated the efficacy of the SAAF formulation for neutral particle transport. Here, the authors apply the SAAF formulation to coupled electron-photon transport problems using multigroup cross sections from the CEPXS code and S n discretization

  6. Self-Adjoint Angular Flux Equation for Coupled Electron-Photon Transport

    International Nuclear Information System (INIS)

    Liscum-Powell, J.L.; Lorence, L.J. Jr.; Morel, J.E.; Prinja, A.K.

    1999-01-01

    Recently, Morel and McGhee described an alternate second-order form of the transport equation called the self adjoint angular flux (SAAF) equation that has the angular flux as its unknown. The SAAF formulation has all the advantages of the traditional even- and odd-parity self-adjoint equations, with the added advantages that it yields the full angular flux when it is numerically solved, it is significantly easier to implement reflective and reflective-like boundary conditions, and in the appropriate form it can be solved in void regions. The SAAF equation has the disadvantage that the angular domain is the full unit sphere and, like the even- and odd- parity form, S n source iteration cannot be implemented using the standard sweeping algorithm. Also, problems arise in pure scattering media. Morel and McGhee demonstrated the efficacy of the SAAF formulation for neutral particle transport. Here we apply the SAAF formulation to coupled electron-photon transport problems using multigroup cross-sections from the CEPXS code and S n discretization

  7. Diamond detector in absorbed dose measurements in high-energy linear accelerator photon and electron beams.

    Science.gov (United States)

    Ravichandran, Ramamoorthy; Binukumar, John Pichy; Al Amri, Iqbal; Davis, Cheriyathmanjiyil Antony

    2016-03-08

    Diamond detectors (DD) are preferred in small field dosimetry of radiation beams because of small dose profile penumbras, better spatial resolution, and tissue-equivalent properties. We investigated a commercially available 'microdiamond' detector in realizing absorbed dose from first principles. A microdiamond detector, type TM 60019 with tandem electrometer is used to measure absorbed doses in water, nylon, and PMMA phantoms. With sensitive volume 0.004 mm3, radius 1.1mm, thickness 1 x10(-3) mm, the nominal response is 1 nC/Gy. It is assumed that the diamond detector could collect total electric charge (nC) developed during irradiation at 0 V bias. We found that dose rate effect is less than 0.7% for changing dose rate by 500 MU/min. The reproducibility in obtaining readings with diamond detector is found to be ± 0.17% (1 SD) (n = 11). The measured absorbed doses for 6 MV and 15 MV photons arrived at using mass energy absorption coefficients and stop-ping power ratios compared well with Nd, water calibrated ion chamber measured absorbed doses within 3% in water, PMMA, and nylon media. The calibration factor obtained for diamond detector confirmed response variation is due to sensitivity due to difference in manufacturing process. For electron beams, we had to apply ratio of electron densities of water to carbon. Our results qualify diamond dosimeter as a transfer standard, based on long-term stability and reproducibility. Based on micro-dimensions, we recommend these detectors for pretreatment dose verifications in small field irradiations like stereotactic treatments with image guidance.

  8. Development of experimental techniques for the characterization of ultrashort photon pulses of extreme ultraviolet free-electron lasers

    Directory of Open Access Journals (Sweden)

    S. Düsterer

    2014-12-01

    Full Text Available One of the most challenging tasks for extreme ultraviolet, soft and hard x-ray free-electron laser photon diagnostics is the precise determination of the photon pulse duration, which is typically in the sub 100 fs range. Nine different methods, able to determine such ultrashort photon pulse durations, were compared experimentally at FLASH, the self-amplified spontaneous emission free-electron laser at DESY in Hamburg, in order to identify advantages and disadvantages of different methods. Radiation pulses at a wavelength of 13.5 and 24.0 nm together with the corresponding electron bunch duration were measured by indirect methods like analyzing spectral correlations, statistical fluctuations, and energy modulations of the electron bunch and also by direct methods like autocorrelation techniques, terahertz streaking, or reflectivity changes of solid state samples. In this paper, we present a comprehensive overview of the various techniques and a comparison of the individual experimental results. The information gained is of utmost importance for the future development of reliable pulse duration monitors indispensable for successful experiments with ultrashort extreme ultraviolet pulses.

  9. Model-independent analysis of polarization effects in elastic electron-deuteron scattering in presence of two-photon exchange

    International Nuclear Information System (INIS)

    Gakh, G.I.; Tomasi-Gustafsson, E.

    2006-01-01

    The general spin structure of the matrix element, taking into account the 2-photon exchange contribution, for the elastic electron (positron) - deuteron scattering has been derived using general symmetry properties of the hadron electromagnetic interaction, such as P-, C- and T-invariances as well as lepton helicity conservation in QED at high energy. Taking into account also crossing symmetry, the amplitudes of e ± d scattering can be parametrized in terms of fifteen real functions. The expressions for the differential cross section and for all polarization observables are given in terms of these functions. We consider the case of an arbitrary polarized deuteron target and polarized electron beam (both longitudinal and transverse). The transverse polarization of the electron beam induces a single-spin asymmetry which is non-zero in presence of 2-photon exchange. It is shown that elastic deuteron electromagnetic form factors can still be extracted in presence of 2 photon exchange, from the measurements of the differential cross sections and of one polarization observable (for example, the tensor asymmetry) for electron and positron deuteron elastic scattering, in the same kinematical conditions. (authors)

  10. Diamond nanoparticles as a way to improve electron transfer in sol-gel L-lactate biosensing platforms.

    Science.gov (United States)

    Briones, M; Casero, E; Vázquez, L; Pariente, F; Lorenzo, E; Petit-Domínguez, M D

    2016-02-18

    In the present work, we have included for the first time diamond nanoparticles (DNPs) in a sol-gel matrix derived from (3-mercaptopropyl)-trimethoxysilane (MPTS) in order to improve electron transfer in a lactate oxidase (LOx) based electrochemical biosensing platform. Firstly, an exhaustive AFM study, including topographical, surface potential (KFM) and capacitance gradient (CG) measurements, of each step involved in the biosensing platform development was performed. The platform is based on gold electrodes (Au) modified with the sol-gel matrix (Au/MPTS) in which diamond nanoparticles (Au/MPTS/DNPs) and lactate oxidase (Au/MPTS/DNPs/LOx) have been included. For the sake of comparison, we have also characterized a gold electrode directly modified with DNPs (Au/DNPs). Secondly, the electrochemical behavior of a redox mediator (hydroxymethyl-ferrocene, HMF) was evaluated at the platforms mentioned above. The response of Au/MPTS/DNPs/LOx towards lactate was obtained. A linear concentration range from 0.053 mM to 1.6 mM, a sensitivity of 2.6 μA mM(-1) and a detection limit of 16 μM were obtained. These analytical properties are comparable to other biosensors, presenting also as advantages that DNPs are inexpensive, environment-friendly and easy-handled nanomaterials. Finally, the developed biosensor was applied for lactate determination in wine samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Radiotherapy gel dosimetry

    International Nuclear Information System (INIS)

    Baldock, C.

    2002-01-01

    In radiotherapy, the primary objective is to deliver a prescribed dose of radiation to a tumour or lesion within a patient while minimising the dose delivered to the surrounding healthy tissue. Traditional radiotherapy treatments usually involve simple external or internal irradiations of a tumour. External irradiations are normally achieved in the clinic with photon or electron beams produced by high energy linear accelerators. The photon or electron beams are collimated into regular shapes as they emerge from the treatment head of the unit which is supported by a gantry that can be rotated isocentrically to any position. A discrete number of photon or electron beams with different angles of incidence that intersect at the iso-centre are used to produce a region of high dose around the tumour volume (positioned at the iso-centre). Internal irradiations are normally achieved in the clinic by implanting radioactive sources in and around the tumour or lesion. Such irradiations are characterised by very high doses local to the tumour. Radioactive sources are also used to prevent post-angioplasty restenosis by inserting sources into arteries. Usually when treating a tumour, a compromise is made between tumour control and complications arising from normal tissue damage. One measure of this compromise, the therapeutic ratio, is defined as the radiation dose producing complications in 50% of patients divided by the dose providing tumour control in 50% of the patients. The therapeutic ratio depends on the radiobiological characteristics of the cancerous tissue and surrounding healthy tissues and on the radiation dose distribution achieved by the radiotherapy treatment. It is generally believed that the therapeutic ratio can be minimised by optimising the conformation of the radiation dose distribution to the target volume. This is difficult with traditional radiotherapy techniques since they do not produce dose distributions that adequately cover tumour volumes of complex

  12. Watching Electrons Transfer from Metals to Insulators using Two Photon Photoemission

    Energy Technology Data Exchange (ETDEWEB)

    Johns, James E. [Univ. of California, Berkeley, CA (United States)

    2010-05-01

    Ultrafast angle-resolved two photon photoemission was used to study the dynamics and interfacial band structure of ultrathin films adsorbed onto Ag(111). Studies focused on the image potential state (IPS) in each system as a probe for measuring changes in electronic behavior in differing environments. The energetics and dynamics of the IPS at the toluene/Ag(111) interface are strongly dependent upon coverage. For a single monolayer, the first IPS is bound by 0.81 eV below the vacuum level and has a lifetime of 50 femtoseconds (fs). Further adsorption of toluene creates islands of toluene with an exposed wetting layer underneath. The IPS is then split into two peaks, one corresponding to the islands and one corresponding to the monolayer. The wetting layer IPS shows the same dynamics as the monolayer, while the lifetime of the islands increases exponentially with increasing thickness. Furthermore, the island IPS transitions from delocalized to localized within 500 fs, and electrons with larger parallel momenta decay much faster. Attempts were made using a stochastic model to extract the rates of localization and intraband cooling at differing momenta. In sexithiophene (6T) and dihexyl-sexithiophene (DH6T), the IPS was used as a probe to see if the nuclear motion of spectating side chains can interfere with molecular conduction. The energy and band mass of the IPS was measured for 6T and two geometries of DH6T on Ag(111). Electrons injected into the thicker coverages of DH6T grew exponentially heavier until they were completely localized by 230 fs, while those injected into 6T remained nearly free electron like. Based off of lifetime arguments and the density of defects, the most likely cause for the mass enhancement of the IPS in this system is small polaron formation caused by coupling of the electron to vibrations of the alkyl substituents. The energetic relaxation of the molecular adsorbate was also measured to be 20 meV/100 fs for the DH6T, and 0 meV/100 fs for

  13. Laser-Driven Very High Energy Electron/Photon Beam Radiation Therapy in Conjunction with a Robotic System

    Directory of Open Access Journals (Sweden)

    Kazuhisa Nakajima

    2014-12-01

    Full Text Available We present a new external-beam radiation therapy system using very-high-energy (VHE electron/photon beams generated by a centimeter-scale laser plasma accelerator built in a robotic system. Most types of external-beam radiation therapy are delivered using a machine called a medical linear accelerator driven by radio frequency (RF power amplifiers, producing electron beams with an energy range of 6–20 MeV, in conjunction with modern radiation therapy technologies for effective shaping of three-dimensional dose distributions and spatially accurate dose delivery with imaging verification. However, the limited penetration depth and low quality of the transverse penumbra at such electron beams delivered from the present RF linear accelerators prevent the implementation of advanced modalities in current cancer treatments. These drawbacks can be overcome if the electron energy is increased to above 50 MeV. To overcome the disadvantages of the present RF-based medical accelerators, harnessing recent advancement of laser-driven plasma accelerators capable of producing 1-GeV electron beams in a 1-cm gas cell, we propose a new embodiment of the external-beam radiation therapy robotic system delivering very high-energy electron/photon beams with an energy of 50–250 MeV; it is more compact, less expensive, and has a simpler operation and higher performance in comparison with the current radiation therapy system.

  14. Monitor unit calculations for external photon and electron beams: Report of the AAPM Therapy Physics Committee Task Group No. 71.

    Science.gov (United States)

    Gibbons, John P; Antolak, John A; Followill, David S; Huq, M Saiful; Klein, Eric E; Lam, Kwok L; Palta, Jatinder R; Roback, Donald M; Reid, Mark; Khan, Faiz M

    2014-03-01

    A protocol is presented for the calculation of monitor units (MU) for photon and electron beams, delivered with and without beam modifiers, for constant source-surface distance (SSD) and source-axis distance (SAD) setups. This protocol was written by Task Group 71 of the Therapy Physics Committee of the American Association of Physicists in Medicine (AAPM) and has been formally approved by the AAPM for clinical use. The protocol defines the nomenclature for the dosimetric quantities used in these calculations, along with instructions for their determination and measurement. Calculations are made using the dose per MU under normalization conditions, D'0, that is determined for each user's photon and electron beams. For electron beams, the depth of normalization is taken to be the depth of maximum dose along the central axis for the same field incident on a water phantom at the same SSD, where D'0 = 1 cGy/MU. For photon beams, this task group recommends that a normalization depth of 10 cm be selected, where an energy-dependent D'0 ≤ 1 cGy/MU is required. This recommendation differs from the more common approach of a normalization depth of dm, with D'0 = 1 cGy/MU, although both systems are acceptable within the current protocol. For photon beams, the formalism includes the use of blocked fields, physical or dynamic wedges, and (static) multileaf collimation. No formalism is provided for intensity modulated radiation therapy calculations, although some general considerations and a review of current calculation techniques are included. For electron beams, the formalism provides for calculations at the standard and extended SSDs using either an effective SSD or an air-gap correction factor. Example tables and problems are included to illustrate the basic concepts within the presented formalism.

  15. Photon multiplicity in the hard radiation of 150 GeV electrons in an aligned germanium crystal

    International Nuclear Information System (INIS)

    Belkacem, A.; Chevallier, M.; Gaillard, M.J.; Genre, R.; Kirsch, R.; Poizat, J.C.; Remillieux, J.; Bologna, G.; Peigneux, J.P.; Sillou, D.; Spighel, M.; Cue, N.; Kimball, J.C.; Marsh, B.B.; Sun, C.R.

    1988-01-01

    Mean values m of photon multiplicity in the radiation of 150 GeV electrons directed at and near the axis of a 0.185 mm thick Ge crystal cooled to 100 K have been deduced from the measurements of pair conversion probabilities. Depending on the distribution of multiplicity assumed, values of m ranging from 3.8 to 4.3 are obtained for the previously reported anomalous radiation peak. (orig.)

  16. Secondary electron radiation from different targets exposed to photons with energy 0.1 to 3 MeV

    International Nuclear Information System (INIS)

    Akkerman, A.F.; Botvin, V.A.; Chernov, G.Ya.

    1982-01-01

    Differential and integral yields of secondary electrons from different targets bombarded by monoenergetic photon beams are calculated using the Monte Carlo method. The results are compared to experimental data and values calculated by other authors. The discovered 20 to 30% decrease of calculated backward yields according to experimental data for heavy elements is explained by the limited applicability of Sauter's formula for the description of photoelectron angular distribution. (author)

  17. Monitor unit calculations for external photon and electron beams: Report of the AAPM Therapy Physics Committee Task Group No. 71

    Energy Technology Data Exchange (ETDEWEB)

    Gibbons, John P., E-mail: john.gibbons@marybird.com [Department of Physics, Mary Bird Perkins Cancer Center, Baton Rouge, Louisiana 70809 (United States); Antolak, John A. [Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota 55905 (United States); Followill, David S. [Department of Radiation Physics, UT M.D. Anderson Cancer Center, Houston, Texas 77030 (United States); Huq, M. Saiful [Department of Radiation Oncology, University of Pittsburgh Cancer Institute, Pittsburgh, Pennsylvania 15232 (United States); Klein, Eric E. [Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri 63110 (United States); Lam, Kwok L. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan 48109 (United States); Palta, Jatinder R. [Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia 23298 (United States); Roback, Donald M. [Department of Radiation Oncology, Cancer Centers of North Carolina, Raleigh, North Carolina 27607 (United States); Reid, Mark [Department of Medical Physics, Fletcher-Allen Health Care, Burlington, Vermont 05401 (United States); Khan, Faiz M. [Department of Radiation Oncology, University of Minnesota, Minneapolis, Minnesota 55455 (United States)

    2014-03-15

    A protocol is presented for the calculation of monitor units (MU) for photon and electron beams, delivered with and without beam modifiers, for constant source-surface distance (SSD) and source-axis distance (SAD) setups. This protocol was written by Task Group 71 of the Therapy Physics Committee of the American Association of Physicists in Medicine (AAPM) and has been formally approved by the AAPM for clinical use. The protocol defines the nomenclature for the dosimetric quantities used in these calculations, along with instructions for their determination and measurement. Calculations are made using the dose per MU under normalization conditions, D{sub 0}{sup ′}, that is determined for each user's photon and electron beams. For electron beams, the depth of normalization is taken to be the depth of maximum dose along the central axis for the same field incident on a water phantom at the same SSD, where D{sub 0}{sup ′} = 1 cGy/MU. For photon beams, this task group recommends that a normalization depth of 10 cm be selected, where an energy-dependent D{sub 0}{sup ′} ≤ 1 cGy/MU is required. This recommendation differs from the more common approach of a normalization depth of d{sub m}, with D{sub 0}{sup ′} = 1 cGy/MU, although both systems are acceptable within the current protocol. For photon beams, the formalism includes the use of blocked fields, physical or dynamic wedges, and (static) multileaf collimation. No formalism is provided for intensity modulated radiation therapy calculations, although some general considerations and a review of current calculation techniques are included. For electron beams, the formalism provides for calculations at the standard and extended SSDs using either an effective SSD or an air-gap correction factor. Example tables and problems are included to illustrate the basic concepts within the presented formalism.

  18. Rb based alkali antimonide high quantum efficiency photocathodes for bright electron beam sources and photon detection applications

    Science.gov (United States)

    Cultrera, L.; Gulliford, C.; Bartnik, A.; Lee, H.; Bazarov, I.

    2017-02-01

    High quantum efficiency alkali antimonide photocathodes have been grown over both stainless steel and glass substrates using sequential evaporation of Sb, K, Rb, and Cs. Quantum efficiencies well above 25% have been measured at 400 nm. A bi-alkali Rb-K-Sb photocathode grown on a stainless steel substrate has been installed in a high voltage DC gun at Cornell University and the intrinsic electron beam emittance was measured at different photon energies.

  19. Dosimetric evaluation of the Fricke gel dosimeter using the spectrophotometric technique for application in electron and neutron dosimetry

    International Nuclear Information System (INIS)

    Mangueira, Thyago Fressatti

    2011-01-01

    The main dosimetric characteristics of the Fricke Xylenol Gel (FXG) solution were established for further application in the measurement of dose distribution of clinical electron fields. The dose-response curves of the FXG in a thermal neutron field were also evaluated for application in Boron Neutron Capture Therapy (BNCT) and industrial electron fields. The standard reading technique was the spectrophotometry. For clinical fields the intra and inter-batch reproducibility of FXG solution are better than 1.4% and 5.1%, respectively. The optical response presents a linear behavior for doses ranging from 0.2 to 40 Gy independently of the electron energy and the dose rate in the studied ranges. Due to the effects of the FXG natural oxidation, the optimum elapsed time between FXG preparation and irradiation was established as 24h. The behavior of the dose-response curve does not change the obtained absorbance values relative to the non-irradiated dosimeter response during the studied period. The dose-response curve to industrial electron beam presented an exponential decreasing behavior. The optical response to thermal neutrons beam presented a linear behavior for the studied dose range. According to the obtained results to the different radiation fields studied it was not observed changes in the wavelength of the typical bands of the absorption spectrum radiation induced. Additional tests were performed with FXG solution to verify the viability and application of FXG dosimetry on intracavitary brachytherapy using digital photographic imaging. The excellent performance of the FXG dosimeter indicates that this dosimeter may be applied to tri-dimensional dose evaluation in radiotherapy treatments using electrons and neutron beams. (author)

  20. Photon-photon collisions

    International Nuclear Information System (INIS)

    Field, J.H.

    1984-01-01

    The current status, both theoretical and experimental, of two photon collision physics is reviewed with special emphasis on recent experimental results from e + e - storage rings. After a complete presentation of the helicity amplitude formalism for the general process e + e - → Xe + e - , various approximations (transverse photon, Weisaecker Williams) are discussed. Beam polarisation effects and radiative corrections are also briefly considered. A number of specific processes, for which experimental results are now available, are then described. In each case existing theoretical prediction are confronted with experimental results. The processes described include single resonance production, lepton and hadron pair production, the structure functions of the photon, the production of high Psub(T) jets and the total photon photon cross section. In the last part of the review the current status of the subject is summarised and some comments are made on future prospects. These include both extrapolations of current research to higher energy machines (LEP, HERA) as well as a brief mention of both the technical realisation and the physics interest of the real γγ and eγ collisions which may be possible using linear electron colliders in the 1 TeV energy range

  1. A supramolecular gel electrolyte formed from amide based co-gelator for quasi-solid-state dye-sensitized solar cell with boosted electron kinetic processes

    Science.gov (United States)

    Huo, Zhipeng; Wang, Lu; Tao, Li; Ding, Yong; Yi, Jinxin; Alsaedi, Ahmed; Hayat, Tasawar; Dai, Songyuan

    2017-08-01

    A supramolecular gel electrolyte (Tgel > 100 °C) is formed from N,N‧-1,8-octanediylbis-dodecanamide and iodoacetamide as two-component co-gelator, and introduced into the quasi-solid-state dye-sensitized solar cells (QS-DSSCs). The different morphologies of microscopic network between two-component and single-component gel electrolytes have influence on the diffusion of redox couple in gel electrolytes and further affect the electron kinetic processes in QS-DSSCs. Compared with the single-component gel electrolyte, the two-component gel electrolyte has less compact gel network and weaker steric hindrance effect, which provides more effective charge transport channel for the diffusion of I3/I- redox couple. Meanwhile, the sbnd NH2 groups of iodoacetamide molecules interact with Li+ and I3-, which also accelerate the transport of I3-/I- and decrease in the I3- concentration in the TiO2/electrolyte interface. As a result, nearly a 12% improvement in short-circuit photocurrent density (Jsc) and much higher open circuit potential (Voc) are found in the two-component gel electrolyte based QS-DSSC. Consequently, the QS-DSSC based on the supramolecular gel electrolyte obtains a 17% enhancement in the photoelectric conversion efficiency (7.32%) in comparison with the QS-DSSC based on the single-component gel electrolyte (6.24%). Furthermore, the degradations of these QS-DSSCs are negligible after one sun light soaking with UV cutoff filter at 50 °C for 1000 h.

  2. ELECTRON MICROSCOPIC INVESTIGATION OF YTTRIUM ALUMINUM GARNET POWDERS Y3AL5O12, SYNTHESIZED BY SOL–GEL METHOD

    Directory of Open Access Journals (Sweden)

    A. E. Baranchikov

    2015-09-01

    Full Text Available Subject of Study. The paper presents results of characterization for neodymium doped yttrium aluminum garnet nanopowders - YAG:Nd3+ by the method of scanning electronic microscopy. Method. Synthesis of YAG:Nd3+ was carried out by sol-gel method from nitrate or acetate - nitrate solutions with addition of some organic compounds and ammonia as well. Such substances were used as the source ones: oxides of neodymium and yttrium with the content of the basic substance equal to 99.999 %; organic compounds: citric acid with the content of the basic substance not less than 99.0 %; ethylene glycol (99.5%; the ammonium lauryl sulfate (99.0 %; urea (99.0 % of Alfa Aesar, Fluka, Aldrich companies. Oxides of yttrium and neodymium (5 at. % were dissolved in 50% acetic acid, nitrate aluminum was added with a view to the resulting product Y2,85Nd0,15Al5,0O12, the solution was stirred and heated to 60С before reaching its transparency and uniformity. The weight of the portion corresponding to the stoichiometry YAG was 2.0 g. 50 % aqueous solutions of organic substances or 5% NH4OH in a weight ratio of 1:1 to the weight of the garnet were added in aqueous solutions, placed into glass cups. The solutions were thoroughly mixed first using a conventional stirrer, then on ultrasonic installation with simultaneous 60 С heating for 2 hours. Drying of solutions to the consistency of a powder or a thick gel was carried out at 110 С. Then the samples were placed into platinum cups and annealed in a tube furnace at 950 - 1050 С for the period from 0.5 to 2 hours. Additional annealing of the powders in the air at 950 - 1060С were carried out for the purpose of powders clarifying for residual amorphous carbon removal. Main Results. The synthesized powder precursors and powders after annealing were examined using a polarizing microscope to identify anisotropic crystalline phases. X-ray analysis of the synthesized samples was carried out on a DRON - 4 and UDR - 63

  3. Photon and electron data bases and their use in radiation transport calculations

    International Nuclear Information System (INIS)

    Cullen, D.E.; Perkins, S.T.; Seltzer, S.M.

    1992-01-01

    Traditionally, the data included in the ENDF/B photon interaction data base have been sufficient to describe the interaction of primary photons with matter. The data usually contained in this data base included: (1) cross sections: coherent and incoherent scattering, pair production as well as photoelectric absorption; and (2) form factors and scattering functions: to describe the angular distribution of coherent and incoherently scattered photons. These data were sufficient to describe the interaction of primary photons with matter. However, they were not adequate to uniquely define the emission of secondary photons following photoelectric effects such as fluorescence. Traditionally, it has been assumed that when a photoelectric event occurs, all of the energy of the incident photons is deposited at the point of the interaction. In fact, in the case of photons with energies near the K photoelectric edge of lead, almost 88% of the energy will be reradiated as fluorescence X rays. Traditional data also did not include the effect of anomalous scattering on coherent scattering. Including this effect predicts a coherent scattering cross section that approaches zero at low energy, as opposed to the constant low-energy limit predicted by simply using form factors. Lastly, traditional data did not differentiate between pair and triplet production

  4. PREFACE: XXIX International Conference on Photonic, Electronic, and Atomic Collisions (ICPEAC2015)

    Science.gov (United States)

    Díaz, C.; Rabadán, I.; García, G.; Méndez, L.; Martín, F.

    2015-09-01

    The 29th International Conference on Photonic, Electronic and Atomic Collisions (XXIX ICPEAC) was held at the Palacio de Congresos ''El Greco'', Toledo, Spain, on 22-28 July, 2015, and was organized by the Universidad Autónoma de Madrid (UAM) and the Consejo Superior de Investigaciones Científicas (CSIC). ICPEAC is held biannually and is one of the most important international conferences on atomic and molecular physics. The topic of the conference covers the recent progresses in photonic, electronic, and atomic collisions with matter. With a history back to 1958, ICPEAC came to Spain in 2015 for the very first time. UAM and CSIC had been preparing the conference for six years, ever since the ICPEAC International General Committee made the decision to hold the XXIX ICPEAC in Toledo. The conference gathered 670 participants from 52 countries and attracted 854 contributed papers for presentation in poster sessions. Among the latter, 754 are presented in issues 2-12 of this volume of the Journal of Physics Conference Series. In addition, five plenary lectures, including the opening one by the Nobel laureate Prof. Ahmed H. Zewail and the lectures by Prof. Maciej Lewenstein, Prof. Paul Scheier, Prof. Philip H. Bucksbaum, and Prof. Stephen J. Buckman, 62 progress reports and 26 special reports were presented following the decision of the ICPEAC International General Committee. Detailed write-ups of most of the latter are presented in issue 1 of this volume, constituting a comprehensive tangible record of the meeting. On the occasion of the International Year of Light (IYL2015) and with the support of the Fundación Española para la Ciencia y la Tecnología (FECYT), the program was completed with two public lectures delivered by the Nobel laureate Prof. Serge Haroche and the Príncipe de Asturias laureate Prof. Pedro M. Echenique on, respectively, ''Fifty years of laser revolutions in physics'rquot; and ''The sublime usefulness of useless science''. Also a

  5. Nuclear physics with laser-electron-photons. Developments and perspectives at SPring-8

    Energy Technology Data Exchange (ETDEWEB)

    Fujiwara, Mamoru [Osaka Univ., Ibaraki (Japan). Research Center for Nuclear Physics

    1998-03-01

    By the Compton scattering with ultraviolet laser beam using the 8 GeV electron beam of the SPring-8, the photon beam which is polarized by nearly 100% is obtained in 1-3.5 GeV region. The quark nuclear physics research at this facility is unique in the world, and it is expected that in the experiment at the SPring-8, the collision phenomena of polarized, high energy gamma-ray and the quarks in nucleons and the knockout phenomena of quarks are observed. Also the polarization experiment for clarifying ``the origin of nucleon spin`` has been proposed. Japan can stand at the top in the world in the research of quark nuclear physics with leptons. In the inverse Compton scattering using far infrared laser, the gamma-ray with good directionality of MeV range is obtained, and it will be applied widely to the research on E1 resonance and M1 excitation of atomic nuclei. In this report, the medium energy quark nuclear physics developed at the SPring-8 is outlined, and the nuclear physics which is expected to be developed when the high intensity, high polarization gamma-ray of about 10 MeV is generated is discussed. The detection of s, anti-s components in nucleons, research on baryon deformation and baryon spectra, verification of the Gerasimov, Drell-Hearn law of sum, meson structure, test of quark model by the photolysis of deuterons, dual Ginzburg Landau theory exploration, research on the mass and behavior of mesons in nuclear media are discussed. (K.I.)

  6. Instrumentation and Beam Dynamics Study of Advanced Electron-Photon Facility in Indiana University

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Tianhuan [Indiana Univ., Bloomington, IN (United States)

    2011-08-01

    The Advanced eLectron-PHoton fAcility (ALPHA) is a compact electron accelerator under construction and being commissioned at the Indiana University Center for Exploration of Energy and Matter (CEEM). In this thesis, we have studied the refurbished Cooler Injector Synchrotron (CIS) RF cavity using both the transmission line model and SUPERFISH simulation. Both low power and high power RF measurements have been carried out to characterize the cavity. Considering the performance limit of ferrite, we have designed a new ferrite loaded, co-axial quarter wave like cavity with similar structure but a more suitable ferrite material. We have also designed a traveling wave stripline kicker for fast extraction by POISSON and Microwave Studio. The strips geometry is trimmed to maximize the uniformity of the kicking field and match the impedance of the power cables. The time response simulation shows the kicker is fast enough for machine operation. The pulsed power supply requirement has also been specified. For the beam diagnosis in the longitudinal direction, we use a wideband Wall Gap Monitor (WGM) served in CIS. With proper shielding and amplification to get good WGM signal, we have characterized the injected and extracted beam signal in single pass commissioning, and also verified the debunching effect of the ALPHA storage ring. A modulation-demodulation signal processing method is developed to measure the current and longitudinal profile of injected beam. By scanning the dipole strength in the injection line, we have reconstructed the tomography of the longitudinal phase space of the LINAC beam. In the accumulation mode, ALPHA will be operated under a low energy and high current condition, where intra beam scattering (IBS) becomes a dominant effect on the beam emittance. A self consistent simulation, including IBS effect, gas scattering and linear coupling, has been carried out to calculate the emittance of the stored beam.

  7. PREFACE: XXVII International Conference on Photonic, Electronic and Atomic Collisions (ICPEAC 2011)

    Science.gov (United States)

    Williams, I. D.; van der Hart, H. W.; McCann, J. F.; Crothers, D. S. F.

    2012-11-01

    The XXVII International Conference on Photonic, Electronic and Atomic Collisions was held at Queen's University Belfast, Northern Ireland, 27 July - 2 August 2011. Members of the Local Organising Committee were drawn from the School of Mathematics and Physics of Queen's University Belfast, the School of Physical Sciences at Dublin City University, the School of Physics at University College Dublin and the Department of Experimental Physics at the National University of Ireland, Maynooth. The Conference was attended by 566 participants with contributions from 54 countries. The meeting attracted 786 contributed papers for presentation in the poster sessions. The conference included 20 Special Reports selected from the contributed papers, and these are included in part 1 of this volume. During the meeting a total of 65 Progress Reports were also presented, and the authors invited to submit written versions of their talks (see Part 1). Of the total number of contributed papers, 663 are included as refereed abstracts in parts 2 to 15 of this volume of Journal of Physics: Conference Series. Part 1 of this volume includes detailed write-ups of the majority of plenary lectures, progress reports and special reports, constituting a comprehensive tangible record of the meeting, and is additionally published in hard-copy as the Conference Proceedings. There were 5 plenary lectures given by Margaret Murnane on Ultrafast processes in atomic dynamics; Chris Greene on Few-body highly-correlated dynamics; Michael Allan on Electron-molecule collisions; Yasunori Yamazaki on Antiproton and positron collisions and Thomas Stöhlker on Relativistic ion collisions. Ian Spielman, winner of the IUPAP Young Scientist Prize for 2011, gave a special lecture entitled Modifying interatomic interactions using Raman coupling: a tale of slowly colliding Bose-Einstein condensates. In addition an evening public lecture by Mike Baillie on How precise tree-ring dating raises issues concerning the

  8. Dosimetric evaluation of the Fricke gel dosimeter using the spectrophotometric technique for application in electron and neutron dosimetry

    International Nuclear Information System (INIS)

    Mangueira, Thyago Fressatti

    2009-01-01

    In this work the main dosimetric characteristics of the Fricke Xylenol Gel (FXG) solution were established for further application in the measurement of dose distribution of clinical electron fields. The dose-response curves of the FXG in a neutron field were also evaluated for the research in Boron Neutron Capture Therapy (BNCT) and industrial electron fields. The standard reading technique was the spectrophotometric. For the clinical field, the intra and inter-batch reproducibility are better than 1.4% and 5.1 %, respectively, the response presents a linear behavior for doses ranging from 0.2 to 40 Gy independently of the energy and the dose rate in the studied ranges. Due to the effects of the FXG natural oxidation, the optimum elapsed time between FXG preparation and irradiation was established as 24h period and the behavior of the dose-response curve of the FXG using the variation in the absorbance relative to the non-irradiated dosimeter as a basis during the whole studied period were not altered. The dose-response to the industrial electron beam presented an exponential decreasing behavior and the neutron beam for research in BNCT presented a linear behavior for the complete studied dose range. According to the obtained results for the different types of radiation studied for the FXG, there was no change in the position of the characteristic bands of the absorption spectrum due to the interaction of these radiation types. Additional tests were performed to determine the digital photographic imaging of FXG analyses viability and the application of FXG dosimetry on intracavitary brachytherapy. The good performance of the FXG dosimeter in the tests that were carried out indicates that this dosimeter may be applied to the tri-dimensional dose evaluation in radiotherapic treatments using electrons and neutron beams. (author)

  9. Dose rate and energy dependence study of methacrylic acid gelatin tetrakis (hydroxymethyl phosphonium chloride gel with flattened and unflattened photon beams

    Directory of Open Access Journals (Sweden)

    P Sathiyaraj

    2018-01-01

    Conclusions: The results clearly show that the MAGAT gel was highly dose rate-dependent and less dependent on energy. The beam quality variation between FF and FFF was less. The similar results obtained using X-ray CT scanner and UV-visible spectrophotometer indicate that this study can be recommended for polymer gel scanning procedure.

  10. ENDL type formats for the LLNL Evaluated Atomic Data Library, EADL, for the Evaluated Electron Data Library, EEDL, and for the Evaluated Photon Data Library, EPDL

    International Nuclear Information System (INIS)

    Perkins, S.T.; Cullen, D.E.

    1994-01-01

    The character file formats for the Lawrence Livermore National Laboratory evaluated atomic relaxation library (EADL), the electron library (EEDL), and the photon library (EPDL) are given in this report. (author). Refs and tabs

  11. ENDL Type Formats for the LLNL Evaluated Atomic Data Library (EADL), Evaluated Electron Data Library (EEDL), and Evaluated Photon Data Library (EPDL)

    International Nuclear Information System (INIS)

    Perkins, S T; Cullen, D E

    2002-01-01

    The character file formats for the Lawrence Livermore National Laboratory evaluated atomic relaxation library (EADL), the electron library (EEDL), and the photon library (EPDL) are given in this report

  12. Effect of age-dependent bone electron density on the calculated dose distribution from kilovoltage and megavoltage photon and electron radiotherapy in paediatric MRI-only treatment planning.

    Science.gov (United States)

    Zeinali-Rafsanjani, B; Faghihi, R; Mosleh-Shirazi, M A; Saeedi-Moghadam, M; Jalli, R; Sina, S

    2018-01-01

    MRI-only treatment planning (TP) can be advantageous in paediatric radiotherapy. However, electron density extraction is necessary for dose calculation. Normally, after bone segmentation, a bulk density is assigned. However, the variation of bone bulk density in patients makes the creation of pseudo CTs challenging. This study aims to assess the effects of bone density variations in children on radiation attenuation and dose calculation for MRI-only TP. Bone contents of dose and beam profile of 150 kVp and 6 MV photon and 6 MeV electron beams were then calculated using Xcom, MCNPX (Monte Carlo N-particle version X) and ORLN phantoms. Using 150 kVp X-rays, the difference in attenuation coefficient was almost 5% between an 11-year-old child and a newborn, and ~8% between an adult and a newborn. With megavoltage radiation, the differences were smaller but still important. For an 18 MV photon beam, the difference of radiation attenuation between an 11-year-old child and a newborn was 4% and ~7.4% between an adult and a newborn. For 6 MeV electrons, dose differences were observed up to the 2 cm depth. The percentage depth dose difference between 1 and 10-year-olds was 18.5%, and between 10 and 15-year-olds was 24%. The results suggest that for MRI-only TP of photon- or electron-beam radiotherapy, the bone densities of each age group should be defined separately for accurate dose calculation. Advances in knowledge: This study highlights the need for more age-specific determination of bone electron density for accurate dose calculations in paediatric MRI-only radiotherapy TP.

  13. The use of intensity-modulated radiation therapy photon beams for improving the dose uniformity of electron beams shaped with MLC.

    Science.gov (United States)

    Mosalaei, Homeira; Karnas, Scott; Shah, Sheel; Van Doodewaard, Sharon; Foster, Tim; Chen, Jeff

    2012-01-01

    Electrons are ideal for treating shallow tumors and sparing adjacent normal tissue. Conventionally, electron beams are collimated by cut-outs that are time-consuming to make and difficult to adapt to tumor shape throughout the course of treatment. We propose that electron cut-outs can be replaced using photon multileaf collimator (MLC). Two major problems of this approach are that the scattering of electrons causes penumbra widening because of a large air gap, and available commercial treatment planning systems (TPSs) do not support MLC-collimated electron beams. In this study, these difficulties were overcome by (1) modeling electron beams collimated by photon MLC for a commercial TPS, and (2) developing a technique to reduce electron beam penumbra by adding low-energy intensity-modulated radiation therapy (IMRT) photons (4 MV). We used blocks to simulate MLC shielding in the TPS. Inverse planning was used to optimize boost photon beams. This technique was applied to a parotid and a central nervous system (CNS) clinical case. Combined photon and electron plans were compared with conventional plans and verified using ion chamber, film, and a 2D diode array. Our studies showed that the beam penumbra for mixed beams with 90 cm source to surface distance (SSD) is comparable with electron applicators and cut-outs at 100 cm SSD. Our mixed-beam technique yielded more uniform dose to the planning target volume and lower doses to various organs at risk for both parotid and CNS clinical cases. The plans were verified with measurements, with more than 95% points passing the gamma criteria of 5% in dose difference and 5 mm for distance to agreement. In conclusion, the study has demonstrated the feasibility and potential advantage of using photon MLC to collimate electron beams with boost photon IMRT fields. Copyright © 2012 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  14. Photonics and Web Engineering 2011, International Journal of Electronics and Telecommunication, vol.57, no 3, pp.421-428, September 2011

    CERN Document Server

    Romaniuk, R S

    2011-01-01

    The paper presents a digest of chosen technical work results shown by young researchers from different technical universities in this country during the SPIE-IEEE Wilga 2011 symposium on Photonics and Web Engineering. Topical tracks of the symposium embraced, among others, nanomaterials and nanotechnologies for photonics and telecom, sensory and nonlinear optical fibers, object oriented design of hardware, photonic metrology, optoelectronics and photonics applications, photonicselectronics co-design, optoelectronic and electronic systems for telecom, astronomy and high energy physics experiments, JET and pi-of-the sky experiments development. The symposium is an annual summary in the development of numerable Ph.D. theses carried out in this country in the area of advanced electronic and photonic systems. It is also an occasion for young researchers to meet together in a large group (under the patronage of IEEE) spanning the whole country with guests from this part of Europe. A digest of Wilga references is pr...

  15. Realization of a Cascaded Quantum System: Heralded Absorption of a Single Photon Qubit by a Single-Electron Charged Quantum Dot.

    Science.gov (United States)

    Delteil, Aymeric; Sun, Zhe; Fält, Stefan; Imamoğlu, Atac

    2017-04-28

    Photonic losses pose a major limitation for the implementation of a quantum state transfer between nodes of a quantum network. A measurement that heralds a successful transfer without revealing any information about the qubit may alleviate this limitation. Here, we demonstrate the heralded absorption of a single photonic qubit, generated by a single neutral quantum dot, by a single-electron charged quantum dot that is located 5 m away. The transfer of quantum information to the spin degree of freedom takes place upon the emission of a photon; for a properly chosen or prepared quantum dot, the detection of this photon yields no information about the qubit. We show that this process can be combined with local operations optically performed on the destination node by measuring classical correlations between the absorbed photon color and the final state of the electron spin. Our work suggests alternative avenues for the realization of quantum information protocols based on cascaded quantum systems.

  16. Selective Two-Photon Absorptive Resonance Femtosecond-Laser Electronic-Excitation Tagging (STARFLEET) Velocimetry in Flow and Combustion Diagnostics

    Science.gov (United States)

    Jiang, Naibo; Halls, Benjamin R.; Stauffer, Hans U.; Roy, Sukesh; Danehy, Paul M.; Gord, James R.

    2016-01-01

    Selective Two-Photon Absorptive Resonance Femtosecond-Laser Electronic-Excitation Tagging (STARFLEET), a non-seeded ultrafast-laser-based velocimetry technique, is demonstrated in reactive and non-reactive flows. STARFLEET is pumped via a two-photon resonance in N2 using 202.25-nm 100-fs light. STARFLEET greatly reduces the per-pulse energy required (30 µJ/pulse) to generate the signature FLEET emission compared to the conventional FLEET technique (1.1 mJ/pulse). This reduction in laser energy results in less energy deposited in the flow, which allows for reduced flow perturbations (reactive and non-reactive), increased thermometric accuracy, and less severe damage to materials. Velocity measurements conducted in a free jet of N2 and in a premixed flame show good agreement with theoretical velocities and further demonstrate the significantly less-intrusive nature of STARFLEET.

  17. Timing Performance of a MCP Photon Detector Read Out with Multi-Channel Electronics for the Torch System

    Science.gov (United States)

    Castillo García, L.; Fopma, J. M.; Forty, R.; Frei, C.; Gao, R.; Gys, T.; Harnew, N.; Piedigrossi, D.

    2014-06-01

    As part of the R&D phase of the (Time Of internally Reflected Cherenkov light) TORCH project, 8×8 pad micro-channel plate photon detectors are being characterized. Multichannel electronics based on fast amplifier discriminator and time digitization conversion ASICs are used to read out and time the charge signals from single photoelectrons. The MCP performance is investigated with a 20ps pulsed blue laser diode. A time resolution of 90ps is achieved. Timing properties are obtained at modest MCP gain, without time walk correction and no fine calibration of the time-to-digital converter circuit. The reference time is provided by a single-channel MCP photon detector coupled to a Constant Fraction Discriminator. Photoelectron detection efficiencies and back-scattering effect are discussed together with the laser source influence on the timing performance.

  18. Measurement of the leptonic structure functions of the photon at PEP [Positron Electron Project

    International Nuclear Information System (INIS)

    Cain, M.P.

    1987-01-01

    At beam energies available at the PEP e + e - storage ring at the Stanford Linear Accelerator Center the cross-section for two-photon particle production is sufficiently large to warrant an investigation of this O(α 4 ) process. Of particular interest is the two-photon process ee → eeμμ at non-zero Q 2 . This channel is not only relatively easy to observe experimentally but also serves as a model for the process ee → eeq bar q. For the case of inelastic eγ scattering the cross-section could be parameterized in terms of the photon structure functions F 1 (x,Q 2 ) and F 2 (x,Q 2 ). In this thesis I will present data on the process ee → eeμμ collected by the Two-Photon collaboration (PEP-9) at PEP. For the subset of data which proceeds by inelastic eγ scattering I will present a procedure for extracting the QED photon structure functions and apply this method to the data. 42 refs., 44 figs

  19. Dosimetric analysis for photon and electron beams in Whole body irradiation

    International Nuclear Information System (INIS)

    Hurtado G, M.

    1998-01-01

    To initiate the Whole body irradiation as an alternative for the treatment of the hematological diseases, leukemia and assistant for the osseous marrow transplantation, it may be taken account the application of International Protocols about control and quality assurance. It is established the intercomparison by the different dosimetric methods: cylindrical ionization chambers and parallel plane, radiographic emulsion film, semiconductor diodes (Mosfet transistors) and TLD-100 thermoluminescent crystals, obtained measurements for 140 x 140 cm 2 fields and large distances 340 cm respect conventional fields in Radiotherapy. The in vitro dosimetry was realized at the Universal Anthropomorphic puppet Alderson Rando basically with the cylindrical crystals (1 mm diameter) of TLD-100 lithium fluoride. It was obtained the dose value with a 0.6 cm 3 cylindrical ionization chamber and the Farmer electrometer for Whole body irradiation (ICT) with photons for electrons and were obtained values with the Markus plane parallel camera. Knowing the dose rate value to the source-surface distance DFS= 80 cm, it was calibrated the crystals with the reference radiation beam of 60 Co for obtaining the response curve: Dose vs. Tl lecture. It was characterized the 10 % of the total population for 300 crystals for applying the statistics corresponding. The luminescence curve obtained of Gaussian form was considered satisfactory by its stability during the pre-anneal lecture and anneal process, getting the main peak lecture at 300 Centigrade according to assigned parameters at lecture equipment TLD Harshaw model 4500. The results indicate the functional dependence with the distance DFS= 340 cm for the following depth PPD, the relations TMR and TPR, the TAR is not calculated by the increment of the dispersion in air. The penumbra increment indicates an increase of the radiation field respect of luminous field. The dispersion angle q 1 respect at the field central axis was determined and was

  20. Extreme Band Engineering of III-Nitride Nanowire Heterostructures for Electronic and Photonic Application

    Science.gov (United States)

    Sarwar, ATM Golam

    Bottom-up nanowires are attractive for realizing semiconductor devices with extreme heterostructures because strain relaxation through the nanowire sidewalls allows the combination of highly lattice mismatched materials without creating dislocations. The resulting nanowires are used to fabricate light-emitting diodes (LEDs), lasers, solar cells, and sensors. The aim of this work is to investigate extreme heterostructures, which are impossible or very hard to realize in conventional planar films, exploiting the strain accommodation property of nanowires and engineer their band structure for novel electronic and photonic applications. To this end, in this thesis, III-Nitride semiconductor nanowires are investigated. In the first part of this work, a complete growth phase diagram of InN nanowires on silicon using plasma assisted molecular beam epitaxy is developed, and structural and optical characteristics are mapped as a function of growth parameters. Next, a novel up-side down pendeoepitaxial growth of InN forming mushroom-like microstructures is demonstrated and detail structural and optical characterizations are performed. Based on this, a method to grow strain-free large area single crystalline InN or thin film is proposed and the growth of InN on patterned GaN is investigated. The optimized growth conditions developed for InN are further used to grow InGaN nanowires graded over the whole composition range. Numerical energy band simulation is performed to better understand the effect of polarization charge on photo-carrier transport in these extremely graded nanowires. A novel photodetector device with negative differential photocurrent is demonstrated using the graded InGaN nanowires. In the second part of this thesis, polarization-induced nanowire light emitting diodes (PINLEDs) are investigated. The electrical and optical properties of the nanowire heterostructure are engineered and optimized for ultraviolet and deep ultraviolet applications. The electrical

  1. Leptonic two-photon events measured with L3 at the Large Electron Positron Collider (LEP)

    CERN Document Server

    Dehmelt, Klaus

    2006-01-01

    Virtual photons can fluctuate into diverse final states and among other processes, such fluctuations can yield muon-pairs. The fluctuation is a statistical process and can be described in terms of structure functions for photons. Apart from supplying another test of QED, purely leptonic processes provide a calibration fro the hadronic processes. We report on a measurement of dimuon events with single-tagged two-photon events from the LEP experiment L3, at c.m.s. energies between 189 GeV and 206 GeV, with an integrated luminosity of $\\mathcal{L}$ = 600 pb$^{-1}$. An overview of the fundamental physical processes, the detector and the anaytical tools, used for measuring dimuon events, and a discussion of the structure of dimuon events will be presented.

  2. Two-photon-induced hot-electron transfer to a single molecule in a scanning tunneling microscope

    International Nuclear Information System (INIS)

    Wu, S. W.; Ho, W.

    2010-01-01

    The junction of a scanning tunneling microscope (STM) operating in the tunneling regime was irradiated with femtosecond laser pulses. A photoexcited hot electron in the STM tip resonantly tunnels into an excited state of a single molecule on the surface, converting it from the neutral to the anion. The electron-transfer rate depends quadratically on the incident laser power, suggesting a two-photon excitation process. This nonlinear optical process is further confirmed by the polarization measurement. Spatial dependence of the electron-transfer rate exhibits atomic-scale variations. A two-pulse correlation experiment reveals the ultrafast dynamic nature of photoinduced charging process in the STM junction. Results from these experiments are important for understanding photoinduced interfacial charge transfer in many nanoscale inorganic-organic structures.

  3. Search for Excited or Exotic Electron Production Using the Dielectron + Photon Signature at CDF in Run II

    Energy Technology Data Exchange (ETDEWEB)

    Gerberich, Heather Kay [Duke Univ., Durham, NC (United States)

    2004-01-01

    The author presents a search for excited or exotic electrons decaying to an electron and a photon with high transverse momentum. An oppositely charged electron is produced in association with the excited electron, yielding a final state dielectron + photon signature. The discovery of excited electrons would be a first indication of lepton compositeness. They use ~ 202 pb-1 of data collected in p$\\bar{p}$ collisions at √s = 1.96 TeV with the Collider Detector at Fermilab during March 2001 through September 2003. The data are consistent with standard model expectations. Upper limits are set on the experimental cross-section σ($\\bar{p}$p → ee* → eeγ) at the 95% confidence level in a contact-interaction model and a gauge-mediated interaction model. Limits are also presented as exclusion regions in the parameter space of the excited electron mass (Me*) and the compositeness energy scale (Λ). In the contact-interaction model, for which there are no previously published limits, they find Me* < 906 GeV is excluded for Me* = Λ. In the gauge-mediated model, the exclusion region in the Me* versus the phenomenological coupling f/Λ parameter space is extended to M{sub e*} < 430 GeV for f/Λ ~ 10-2 GeV-1. In comparison, other experiments have excluded Me* < 280 GeV for f/Λ ~ 10-2 GeV-1.

  4. Characterization and attenuation study on tannin-added Rhizophora spp. particleboard at high energy photon and electron

    Science.gov (United States)

    Yusof, Mohd Fahmi Mohd; Hamid, Puteri Nor Khatijah Abd; Tajuddin, Abd Aziz; Abdullah, Reduan; Hashim, Rokiah; Bauk, Sabar; Isa, Norriza Mohd; Isa, Muhammad Jamal Md

    2017-01-01

    The effective atomic number of tannin-added Rhizophora spp. particleboards was determined based on elemental composition using Energy Dispersive X-ray Analysis (EDXA). The value of mass attenuation coefficients were measured using 137Cs and 60Co gamma energies. The attenuation properties of PDD curves and beam profile of tannin-added Rhizophora spp. particleboards were investigated using Gafchromic EBT2 film at 6 MV photon and 6 MeV electrons and compared to the value in water and solid water phantoms. The results showed that tannin-added Rhizophora spp. particleboards having effective atomic number close to the value of water. The mass attenuation coefficients were near to the value of water with χ2 values of 0.018 and 0.357 to 137Cs and 60Co gamma energies respectively. The PDD of tannin-added Rhizophora spp. particleboards at 6 MV photons showed good agreement within 3.21 and 5.91% to that in solid water phantoms and water respectively. The PDD at 6 MeV electrons showed a good agreement within 3.32 and 3.12% to that in solid water phantoms and water respectively. The depth of R50 and R90 in tannin-added Rhizophora spp. also showed a good agreement to that in water and solid water pahtoms. Lower surface dose was observed in tannin-added Rhizophora spp. particleboards at electron beams in comparison to solid water phantoms and water.

  5. Combined photon-electron beams in the treatment of the supraclavicular lymph nodes in breast cancer: A novel technique that achieves adequate coverage while reducing lung dose

    Energy Technology Data Exchange (ETDEWEB)

    Salem, Ahmed, E-mail: ahmed.salem@doctors.org.uk [Department of Radiation Oncology, King Hussein Cancer Center, Amman (Jordan); Mohamad, Issa; Dayyat, Abdulmajeed [Department of Radiation Oncology, King Hussein Cancer Center, Amman (Jordan); Kanaa’n, Haitham [Section of Medical Physics, Department of Radiation Oncology, King Hussein Cancer Center, Amman (Jordan); Sarhan, Nasim [Department of Radiation Oncology, King Hussein Cancer Center, Amman (Jordan); Roujob, Ibrahim [Section of Medical Physics, Department of Radiation Oncology, King Hussein Cancer Center, Amman (Jordan); Salem, Abdel-Fattah [Department of Obstetrics and Gynecology, Hashemite University, Zarqa (Jordan); Afifi, Shatha [Section of Medical Physics, Department of Radiation Oncology, King Hussein Cancer Center, Amman (Jordan); Jaradat, Imad; Mubiden, Rasmi; Almousa, Abdelateif [Department of Radiation Oncology, King Hussein Cancer Center, Amman (Jordan)

    2015-10-01

    Radiation pneumonitis is a well-documented side effect of radiation therapy for breast cancer. The purpose of this study was to compare combined photon-electron, photon-only, and electron-only plans in the radiation treatment of the supraclavicular lymph nodes. In total, 13 patients requiring chest wall and supraclavicular nodal irradiation were planned retrospectively using combined photon-electron, photon-only, and electron-only supraclavicular beams. A dose of 50 Gy over 25 fractions was prescribed. Chest wall irradiation parameters were fixed for all plans. The goal of this planning effort was to cover 95% of the supraclavicular clinical target volume (CTV) with 95% of the prescribed dose and to minimize the volume receiving ≥ 105% of the dose. Comparative end points were supraclavicular CTV coverage (volume covered by the 95% isodose line), hotspot volume, maximum radiation dose, contralateral breast dose, mean total lung dose, total lung volume percentage receiving at least 20 Gy (V{sub 20} {sub Gy}), heart volume percentage receiving at least 25 Gy (V{sub 25} {sub Gy}). Electron and photon energies ranged from 8 to 18 MeV and 4 to 6 MV, respectively. The ratio of photon-to-electron fractions in combined beams ranged from 5:20 to 15:10. Supraclavicular nodal coverage was highest in photon-only (mean = 96.2 ± 3.5%) followed closely by combined photon-electron (mean = 94.2 ± 2.5%) and lowest in electron-only plans (mean = 81.7 ± 14.8%, p < 0.001). The volume of tissue receiving ≥ 105% of the prescription dose was higher in the electron-only (mean = 69.7 ± 56.1 cm{sup 3}) as opposed to combined photon-electron (mean = 50.8 ± 40.9 cm{sup 3}) and photon-only beams (mean = 32.2 ± 28.1 cm{sup 3}, p = 0.114). Heart V{sub 25} {sub Gy} was not statistically different among the plans (p = 0.999). Total lung V{sub 20} {sub Gy} was lowest in electron-only (mean = 10.9 ± 2.3%) followed by combined photon-electron (mean = 13.8 ± 2.3%) and highest in photon

  6. ITS Version 3.0: The Integrated TIGER Series of coupled electron/photon Monte Carlo transport codes

    International Nuclear Information System (INIS)

    Halbleib, J.A.; Kensek, R.P.; Valdez, G.D.; Mehlhorn, T.A.; Seltzer, S.M.; Berger, M.J.

    1993-01-01

    ITS is a powerful and user-friendly software package permitting state-of-the-art Monte Carlo solution of linear time-independent coupled electron/photon radiation transport problems, with or without the presence of macroscopic electric and magnetic fields. It combines operational simplicity and physical accuracy in order to provide experimentalists and theorists alike with a method for the routine but rigorous solution of sophisticated radiation transport problems. Flexibility of construction permits tailoring of the codes to specific applications and extension of code capabilities to more complex applications through simple update procedures

  7. Electron-photon angular correlation measurements of He (1 1S0-2 1P1) excitation by electron impact at 80 eV

    International Nuclear Information System (INIS)

    Steph, N.C.; Golden, D.E.

    1980-01-01

    The electron-photon angular correlation function was measured between 80-eV electrons which excited the 2 1 P 1 state of helium and 58.4-nm photons from the decay of that state for electron scattering angles ranging from 5 0 to 100 0 . The data have been analyzed to yield values of the ratio lambda of the differential cross section for exciting the M/sub j/=0 sublevel to the total differential cross section and the magnitude vertical-barchivertical-bar of the phase difference between the M/sub j/=0 and M/sub j/=1 excitation amplitudes. The data agree with all previous measurements within one standard deviation, with the exception of the large-angle values of lambda obtained by Hollywood, Crowe, and Williams. Possible causes of these discrepancies are discussed. The values of lambda and vertical-barchivertical-bar obtained in this work agree quite well with those given by the distorted-wave calculations of Madison over the entire angular range

  8. Dosimetry of an accident in mixed field (neutrons, photons) using the spectrometry by electronic paramagnetic resonance(EPR)

    International Nuclear Information System (INIS)

    Herve, M.L.

    2006-03-01

    In a radiological accident, the assessment of the dose received by the victim is relevant information for the therapeutic strategy. Two complementary dosimetric techniques based on physical means are used in routine practice in the laboratory: EPR spectroscopy performed on materials removed from the victim or gathered from the vicinity of the victim and Monte Carlo calculations. EPR dosimetry, has been used successfully several times in cases of photon or electron overexposures. Accidental exposure may also occur with a neutron component. The aim of this work is to investigate the potentiality of EPR dosimetry for mixed photon and neutron field exposure with different organic materials (ascorbic acid, sorbitol, glucose, galactose, fructose, mannose, lactose and sucrose). The influence of irradiation parameters (dose, dose rate, photon energy) and of environmental parameters (temperature of heating, light exposure) on the EPR signal amplitude was studied. To assess the neutron sensitivity, the materials were exposed to a mixed radiation field of experimental reactors with different neutron to photon ratios. The relative neutron sensitivity was found to range from 10% to 43% according to the materials. Prior knowledge of the ratio between the dose in samples measured by EPR spectrometry and organ or whole body dose obtained by calculations previously performed for these different configurations, makes it possible to give a first estimation of the dose received by the victim in a short delay. The second aim of this work is to provide data relevant for a quick assessment of the dose distribution in case of accidental overexposure based on EPR measurements performed on one or several points of the body. The study consists in determining by calculation the relation between the dose to the organs and whole body and the dose to specific points of the body, like teeth, bones or samples located in the pockets of victim clothes, for different external exposures corresponding

  9. Matching extended-SSD electron beams to multileaf collimated photon beams in the treatment of head and neck cancer

    International Nuclear Information System (INIS)

    Steel, Jared; Stewart, Allan; Satory, Philip

    2009-01-01

    Purpose: Matching the penumbra of a 6 MeV electron beam to the penumbra of a 6 MV photon beam is a dose optimization challenge, especially when the electron beam is applied from an extended source-to-surface distance (SSD), as in the case of some head and neck treatments. Traditionally low melting point alloy blocks have been used to define the photon beam shielding over the spinal cord region. However, these are inherently time consuming to construct and employ in the clinical situation. Multileaf collimators (MLCs) provide a fast and reproducible shielding option but generate geometrically nonconformal approximations to the desired beam edge definition. The effects of substituting Cerrobend for the MLC shielding mode in the context of beam matching with extended-SSD electron beams are the subject of this investigation. Methods: Relative dose beam data from a Varian EX 2100 linear accelerator were acquired in a water tank under the 6 MeV electron beam at both standard and extended-SSD and under the 6 MV photon beam defined by Cerrobend and a number of MLC stepping regimes. The effect of increasing the electron beam SSD on the beam penumbra was assessed. MLC stepping was also assessed in terms of the effects on both the mean photon beam penumbra and the intraleaf dose-profile nonuniformity relative to the MLC midleaf. Computational techniques were used to combine the beam data so as to simulate composite relative dosimetry in the water tank, allowing fine control of beam abutment gap variation. Idealized volumetric dosimetry was generated based on the percentage depth-dose data for the beam modes and the abutment geometries involved. Comparison was made between each composite dosimetry dataset and the relevant ideal dosimetry dataset by way of subtraction. Results: Weighted dose-difference volume histograms (DDVHs) were produced, and these, in turn, summed to provide an overall dosimetry score for each abutment and shielding type/angle combination. Increasing the

  10. Disintegration of Ta and W nuclei by high-energy electrons and photons

    International Nuclear Information System (INIS)

    Mitrofanova, A.V.; Noga, V.I.; Popov, A.I.; Ranyuk, Yu.N.; Telegin, Yu.N.

    1977-01-01

    The induced activity method is applied to measure the yields of 15 photonuclear reactions on the tantalum and tungsten nuclei in the 600-1300 MeV energy range of photons. The cross sections are calculated in the ''rectangular'' approximation of the bremsstrahlung spectrum. The data are analysed by the Rudstam semiempirical formula. For the reactions with tungsten nuclei the photo- to electro-yield ratios are measured

  11. Hydrogen production by tuning the photonic band gap with the electronic band gap of TiO₂.

    Science.gov (United States)

    Waterhouse, G I N; Wahab, A K; Al-Oufi, M; Jovic, V; Anjum, D H; Sun-Waterhouse, D; Llorca, J; Idriss, H

    2013-10-10

    Tuning the photonic band gap (PBG) to the electronic band gap (EBG) of Au/TiO2 catalysts resulted in considerable enhancement of the photocatalytic water splitting to hydrogen under direct sunlight. Au/TiO2 (PBG-357 nm) photocatalyst exhibited superior photocatalytic performance under both UV and sunlight compared to the Au/TiO2 (PBG-585 nm) photocatalyst and both are higher than Au/TiO2 without the 3 dimensionally ordered macro-porous structure materials. The very high photocatalytic activity is attributed to suppression of a fraction of electron-hole recombination route due to the co-incidence of the PBG with the EBG of TiO2 These materials that maintain their activity with very small amount of sacrificial agents (down to 0.5 vol.% of ethanol) are poised to find direct applications because of their high activity, low cost of the process, simplicity and stability.

  12. Hydrogen production by Tuning the Photonic Band Gap with the Electronic Band Gap of TiO2

    KAUST Repository

    Waterhouse, G. I. N.

    2013-10-10

    Tuning the photonic band gap (PBG) to the electronic band gap (EBG) of Au/TiO2 catalysts resulted in considerable enhancement of the photocatalytic water splitting to hydrogen under direct sunlight. Au/TiO2 (PBG-357 nm) photocatalyst exhibited superior photocatalytic performance under both UV and sunlight compared to the Au/TiO2 (PBG-585 nm) photocatalyst and both are higher than Au/TiO2 without the 3 dimensionally ordered macro-porous structure materials. The very high photocatalytic activity is attributed to suppression of a fraction of electron-hole recombination route due to the co-incidence of the PBG with the EBG of TiO2 These materials that maintain their activity with very small amount of sacrificial agents (down to 0.5 vol.% of ethanol) are poised to find direct applications because of their high activity, low cost of the process, simplicity and stability.

  13. Acute toxicity and treatment interruption related to electron and photon craniospinal irradiation in pediatric patients treated at the University of Texas M. D. Anderson Cancer Center

    International Nuclear Information System (INIS)

    Chang, Eric L.; Allen, Pamela; Wu, Catherine; Ater, Joann; Kuttesch, John; Maor, Moshe H.

    2002-01-01

    Purpose: To determine the incidence of acute toxicity and treatment interruption associated with electron and photon craniospinal irradiation (CSI) in children treated with or without chemotherapy. Methods and Materials: A retrospective study involving a computerized search of the radiotherapy database at the University of Texas M. D. Anderson Cancer Center identified a total of 79 eligible patients ≤18 years old who had received electron (n=46) or photon (n=33) CSI from October 1980 to March 2000. Acute toxicity was graded according to the 1998 National Cancer Institute Common Toxicity Criteria. Chemotherapy sequencing was categorized as before or after CSI or no chemotherapy. The incidences of weight loss and skin toxicity were recorded and differences in treatment interruption and hematologic values with respect to modality used (electron vs. photon), age (≤6 or >6 years), and sequencing of chemotherapy were compared using chi-square tests. Results: The median age of the electron group was lower than that of the photon group (6.7 years and 11.7 years, respectively). The two groups were otherwise well matched in terms of median spinal dose (31.1 vs. 33.3 Gy), fraction size (1.57 vs. 1.63 Gy), and total treatment time (32.4 vs. 30.7 days). Only 2 patients in each group (photon and electron) had a treatment break (>3 days). The mean number of days interrupted was 0.94 (photon) and 1.1 (electron) (p=0.72). The electron and photon groups were well balanced in terms of receiving pre-CSI chemotherapy (37% vs. 41%, p=0.776). Chemotherapy given before radiotherapy vs. after or not at all was associated with an increased incidence of Grade 3-4 leukopenia (76% vs. 49%, p=0.02), thrombocytopenia (90% vs. 10%, p=0), and neutropenia (50% vs. 15%, p=0.005). A younger age was associated with Grade 3-4 thrombocytopenia (29% vs. 8.7%, p=0.034), and decreased hemoglobin (29% vs. 6.5%, p=0.014). The incidence of leukocyte depression of Grade 3-4 toxicity was 62% in the electron

  14. Multi-anode photon-multiplier readout electronics for the LHCb ring imaging Cherenkov detectors

    CERN Document Server

    Smale, N J

    2004-01-01

    A readout system for the Ring Imaging CHerenkov (RICH) detectors of the LHCb experiment has been developed. Two detector technologies for the measurement of Cherenkov photons are considered, the Multi-Anode Photo-Multiplier Tube (MAPMT) and the Hybrid Photon Detector (HPD), both of which meet the RICH requirements. The properties of the MAPMT are evaluated using a controlled single-photon source; a pixel-to-pixel gain variation of ~3 and a typical signal to noise of ~20 is measured. The relative tube efficiency is found to be reduced by ~26 % due to the detailed focusing structure of the MAPMT device. A radiation hard application-specific integrated circuit (ASIC) chip, the Beetle1.2MA0, has been developed to capture and store signals from a pair of MAPMTs. The Beetle1.2MA0 is built on the architecture of the Beetle family that was designed for silicon strip detectors, the difference being a modified front-end amplifier. The 128 input-channels of the Beetle1.2MA0 have a charge-sensitive pre-amplifier followed...

  15. Study of the material photon and electron background and the liquid argon detector veto efficiency of the CDEX-10 experiment

    Science.gov (United States)

    Su, Jian; Zeng, Zhi; Ma, Hao; Yue, Qian; Cheng, Jian-Ping; Chang, Jian-Ping; Chen, Nan; Chen, Ning; Chen, Qing-Hao; Chen, Yun-Hua; Chuang, Yo-Chun; Deng, Zhi; Du, Qiang; Gong, Hui; Hao, Xi-Qing; He, Qing-Ju; Huang, Han-Xiong; Huang, Teng-Rui; Jiang, Hao; Kang, Ke-Jun; Li, Hau-Bin; Li, Jian-Min; Li, Jin; Li, Jun; Li, Xia; Li, Xin-Ying; Li, Xue-Qian; Li, Yu-Lan; Li, Yuan-Jing; Liao, Heng-Yi; Lin, Fong-Kay; Lin, Shin-Ted; Liu, Shu-Kui; Lü, Lan-Chun; Mao, Shao-Ji; Qin, Jian-Qiang; Ren, Jie; Ren, Jing; Ruan, Xi-Chao; Shen, Man-Bin; Lakhwinder, Singh; Manoj, Kumar Singh; Arun, Kumar Soma; Tang, Chang-Jian; Tseng, Chao-Hsiung; Wang, Ji-Min; Wang, Li; Wang, Qing; Wong Tsz-King, Henry; Wu, Shi-Yong; Wu, Yu-Cheng; Xing, Hao-Yang; Xu, Yin; Xue, Tao; Yang, Li-Tao; Yang, Song-Wei; Yi, Nan; Yu, Chun-Xu; Yu, Hao; Yu, Xun-Zhen; Zeng, Xiong-Hui; Zhang, Lan; Zhang, Yun-Hua; Zhao, Ming-Gang; Zhao, Wei; Zhou, Zu-Ying; Zhu, Jing-Jun; Zhu, Wei-Bin; Zhu, Xue-Zhou; Zhu, Zhong-Hua; CDEX Collaboration

    2015-03-01

    The China Dark Matter Experiment (CDEX) is located at the China Jinping Underground Laboratory (CJPL) and aims to directly detect the weakly interacting massive particles (WIMP) flux with high sensitivity in the low mass region. Here we present a study of the predicted photon and electron backgrounds including the background contribution of the structure materials of the germanium detector, the passive shielding materials, and the intrinsic radioactivity of the liquid argon that serves as an anti-Compton active shielding detector. A detailed geometry is modeled and the background contribution has been simulated based on the measured radioactivities of all possible components within the GEANT4 program. Then the photon and electron background level in the energy region of interest (<10-2events·kg1·day-1·keV-1 (cpkkd)) is predicted based on Monte Carlo simulations. The simulated result is consistent with the design goal of the CDEX-10 experiment, 0.1cpkkd, which shows that the active and passive shield design of CDEX-10 is effective and feasible. Supported by National Natural Science Foundation of China (11175099, 10935005, 10945002, 11275107, 11105076) and State Key Development Program of Basic Research of China (2010CB833006)

  16. Fabrication and characterisation of phantom material made of Tannin-added Rhizophora spp. particleboards for photon and electron beams

    International Nuclear Information System (INIS)

    Yusof, M F Mohd; Hamid, P N K Abd; Tajuddin, A A; Bauk, S; Hashim, R; Isa, N Mohd; Isa, M J Md

    2017-01-01

    Particleboards made of Rhizophora spp. with addition of tannin adhesive were fabricated at target density of 1.0 g/cm 3 . The physical and mechanical properties of the particleboards including internal bond strength (IB) and modulus of rupture (MOR) were measured based on Japanese Industrial Standards (JIS A-5908). The characterisation of the particleboards including the effective atomic number, CT number and relative electron density were determined and compared to water. The mass attenuation coefficient of the particleboards were measured and compared to the calculated value of water using photon cross-section database (XCOM). The results showed that the physical and mechanical properties of the particleboards complied with Type 13 and 18 of JIS A-5908. The values of effective atomic number, CT number and relative electron density were also close to the value of water. The value of mass attenuation coefficients of the particleboards showed good agreement with water (XCOM) at low and high energy photon indicated by the χ 2 values. (paper)

  17. Study of the material photon and electron background and the liquid argon detector veto efficiency of the CDEX-10 experiment

    International Nuclear Information System (INIS)

    Su Jian; Zeng Zhi; Ma Hao

    2015-01-01

    The China Dark Matter Experiment (CDEX) is located at the China Jinping Underground Laboratory (CJPL) and aims to directly detect the weakly interacting massive particles (WIMP) flux with high sensitivity in the low mass region. Here we present a study of the predicted photon and electron backgrounds including the background contribution of the structure materials of the germanium detector, the passive shielding materials, and the intrinsic radioactivity of the liquid argon that serves as an anti-Compton active shielding detector. A detailed geometry is modeled and the background contribution has been simulated based on the measured radioactivities of all possible components within the GEANT4 program. Then the photon and electron background level in the energy region of interest (< 10 -2 events·kg 1 ·day -1 ·keV -1 (cpkkd)) is predicted based on Monte Carlo simulations. The simulated result is consistent with the design goal of the CDEX-10 experiment, 0.1cpkkd, which shows that the active and passive shield design of CDEX-10 is effective and feasible. (authors)

  18. Fabrication and characterisation of phantom material made of Tannin-added Rhizophora spp. particleboards for photon and electron beams

    Science.gov (United States)

    Yusof, M. F. Mohd; Hamid, P. N. K. Abd; Tajuddin, A. A.; Hashim, R.; Bauk, S.; Isa, N. Mohd; Isa, M. J. Md

    2017-05-01

    Particleboards made of Rhizophora spp. with addition of tannin adhesive were fabricated at target density of 1.0 g/cm3. The physical and mechanical properties of the particleboards including internal bond strength (IB) and modulus of rupture (MOR) were measured based on Japanese Industrial Standards (JIS A-5908). The characterisation of the particleboards including the effective atomic number, CT number and relative electron density were determined and compared to water. The mass attenuation coefficient of the particleboards were measured and compared to the calculated value of water using photon cross-section database (XCOM). The results showed that the physical and mechanical properties of the particleboards complied with Type 13 and 18 of JIS A-5908. The values of effective atomic number, CT number and relative electron density were also close to the value of water. The value of mass attenuation coefficients of the particleboards showed good agreement with water (XCOM) at low and high energy photon indicated by the χ2 values.

  19. Quality control of radiotherapy centres in the Slovak Republic: a dosimetry intercomparison of photon and electron beams under reference conditions

    International Nuclear Information System (INIS)

    Gomola, I.; Kralik, G.; Laginova, V.; Van Dam, J.

    2001-01-01

    The aim of this paper is a dosimetry intercomparison of photon and electron beams under reference conditions as well as quality control of radiotherapy centres in the Slovak Republic. The results obtained in the first check shows that only about 60% of beams are within the acceptance limit. The reasons of discrepancies were traced, in some cases by an on site visit of experts from the NRC, and unacceptable deviations were corrected. The results clearly demonstrate the usefulness of the external dosimetry checks performed with the mailed thermoluminescent dosimeters. Standard deviation of the distribution of the results decreased from SD=4.3% to SD=I.8% for checked photon beams and from SD=8.6% to SD=2.4% for electron beams, respectively, at the end of the project. The dosimetry audits which are performed in regular intervals significantly decreasing a possibility of mistreatment (under-dosage or over-dosage ) of patients due to wrong calibration of radiation therapy beams. In order to keep the reached level of dosimetry precision, it is necessary to establish the external audit in radiotherapy at the national level based on postal TLD dosimetry by transferring the know-how from the international program on quality assurance in radiotherapy dosimetry with the assistance of the IAEA. (authors)

  20. Displacement damage analysis and modified electrical equivalent circuit for electron and photon-irradiated silicon solar cells

    Science.gov (United States)

    Arjhangmehr, Afshin; Feghhi, Seyed Amir Hossein

    2014-10-01

    Solar modules and arrays are the conventional energy resources of space satellites. Outside the earth's atmosphere, solar panels experience abnormal radiation environments and because of incident particles, photovoltaic (PV) parameters degrade. This article tries to analyze the electrical performance of electron and photon-irradiated mono-crystalline silicon (mono-Si) solar cells. PV cells are irradiated by mono-energetic electrons and poly-energetic photons and immediately characterized after the irradiation. The mean degradation of the maximum power (Pmax) of silicon solar cells is presented and correlated using the displacement damage dose (Dd) methodology. This method simplifies evaluation of cell performance in space radiation environments and produces a single characteristic curve for Pmax degradation. Furthermore, complete analysis of the results revealed that the open-circuit voltage (Voc) and the filling factor of mono-Si cells did not significantly change during the irradiation and were independent of the radiation type and fluence. Moreover, a new technique is developed that adapts the irradiation-induced effects in a single-cell equivalent electrical circuit and adjusts its elements. The "modified circuit" is capable of modeling the "radiation damage" in the electrical behavior of mono-Si solar cells and simplifies the designing of the compensation circuits.

  1. Carbon nanotubes--electronic/electrochemical properties and application for nanoelectronics and photonics.

    Science.gov (United States)

    Sgobba, Vito; Guldi, Dirk M

    2009-01-01

    The fundamental chemical, redox, electrochemical, photoelectrochemical, optical and optoelectronic features of carbon nanotubes are surveyed with particular emphasis on the most relevant applications as electron donor/electron acceptor or as electron conductor/hole conductor materials, in solutions and in the solid state. Methods that aim at p- and n-doping as a means to favor hole or electron injection/transport are covered as well (critical review, 208 references).

  2. A new gel using super absorbent polymer for mapping the spatial dose distributions of electron beams by MR imager.

    Science.gov (United States)

    Hiraoka, T; Hoshino, K; Kawashima, K; Kato, H; Tateno, Y

    1993-01-01

    A technique for mapping the spatial dose distribution with a magnetic resonance imager is presented. A ferrous sulphate solution with sulfuric acid was used as the detecting medium for radiation dose. To make a gel of the solution for filling up a cubic phantom, we developed a new gel component that is combined with a super absorbent polymer (Sumikagel N-100) and a cross-linked dextran gel (Sephadex G-200). In order to make the application for radiation treatment planning, mapping of the dose distribution was carried out using a Unix computer.

  3. Monte Carlo benchmark calculations of energy deposition by electron/photon showers up to 1 GeV

    International Nuclear Information System (INIS)

    Mehlhorn, T.A.; Halbleib, J.A.

    1983-01-01

    Over the past several years the TIGER series of coupled electron/photon Monte Carlo transport codes has been applied to a variety of problems involving nuclear and space radiations, electron accelerators, and radioactive sources. In particular, they have been used at Sandia to simulate the interaction of electron beams, generated by pulsed-power accelerators, with various target materials for weapons effect simulation, and electron beam fusion. These codes are based on the ETRAN system which was developed for an energy range from about 10 keV up to a few tens of MeV. In this paper we will discuss the modifications that were made to the TIGER series of codes in order to extend their applicability to energies of interest to the high energy physics community (up to 1 GeV). We report the results of a series of benchmark calculations of the energy deposition by high energy electron beams in various materials using the modified codes. These results are then compared with the published results of various experimental measurements and other computational models

  4. Many-Body Theory of Proton-Generated Point Defects for Losses of Electron Energy and Photons in Quantum Wells

    Science.gov (United States)

    Huang, Danhong; Iurov, Andrii; Gao, Fei; Gumbs, Godfrey; Cardimona, D. A.

    2018-02-01

    The effects of point defects on the loss of either energies of ballistic electron beams or incident photons are studied by using a many-body theory in a multi-quantum-well system. This theory includes the defect-induced vertex correction to a bare polarization function of electrons within the ladder approximation, and the intralayer and interlayer screening of defect-electron interactions is also taken into account in the random-phase approximation. The numerical results of defect effects on both energy-loss and optical-absorption spectra are presented and analyzed for various defect densities, numbers of quantum wells, and wave vectors. The diffusion-reaction equation is employed for calculating distributions of point defects in a layered structure. For completeness, the production rate for Frenkel-pair defects and their initial concentration are obtained based on atomic-level molecular-dynamics simulations. By combining the defect-effect, diffusion-reaction, and molecular-dynamics models with an available space-weather-forecast model, it will be possible in the future to enable specific designing for electronic and optoelectronic quantum devices that will be operated in space with radiation-hardening protection and, therefore, effectively extend the lifetime of these satellite onboard electronic and optoelectronic devices. Specifically, this theory can lead to a better characterization of quantum-well photodetectors not only for high quantum efficiency and low dark current density but also for radiation tolerance or mitigating the effects of the radiation.

  5. Quantum photonics

    CERN Document Server

    Pearsall, Thomas P

    2017-01-01

    This textbook employs a pedagogical approach that facilitates access to the fundamentals of Quantum Photonics. It contains an introductory description of the quantum properties of photons through the second quantization of the electromagnetic field, introducing stimulated and spontaneous emission of photons at the quantum level. Schrödinger’s equation is used to describe the behavior of electrons in a one-dimensional potential. Tunneling through a barrier is used to introduce the concept of non­locality of an electron at the quantum level, which is closely-related to quantum confinement tunneling, resonant tunneling, and the origin of energy bands in both periodic (crystalline) and aperiodic (non-crystalline) materials. Introducing the concepts of reciprocal space, Brillouin zones, and Bloch’s theorem, the determination of electronic band structure using the pseudopotential method is presented, allowing direct computation of the band structures of most group IV, group III-V, and group II-VI semiconducto...

  6. Liquid argon as an electron/photon detector in the energy range of 50 MeV to 2 GeV: a Monte Carlo investigation

    International Nuclear Information System (INIS)

    Goodman, M.S.; Denis, G.; Hall, M.; Karpovsky, A.; Wilson, R.; Gabriel, T.A.; Bishop, B.L.

    1980-12-01

    Monte Carlo techniques which have been used to study the characteristics of a proposed electron/photon detector based on the total absorption of electromagnetic showers in liquid argon have been investigated. The energy range studied was 50 MeV to 2 GeV. Results are presented on the energy and angular resolution predicted for the device, along with the detailed predictions of the transverse and longitudinal shower distributions. Comparisons are made with other photon detectors, and possible applications are discussed

  7. Subgap Two-Photon States in Polycyclic Aromatic Hydrocarbons: Evidence for Strong Electron Correlations

    OpenAIRE

    Aryanpour, K.; Roberts, A.; Sandhu, A.; Rathore, R.; Shukla, A.; Mazumdar, S.

    2013-01-01

    Strong electron correlation effects in the photophysics of quasi-one-dimensional $\\pi$-conjugated organic systems such as polyenes, polyacetylenes, polydiacetylenes, etc., have been extensively studied. Far less is known on correlation effects in two-dimensional $\\pi$-conjugated systems. Here we present theoretical and experimental evidence for moderate repulsive electron-electron interactions in a number of finite polycyclic aromatic hydrocarbon molecules with $D_{6h}$ symmetry. We show that...

  8. Implementation of MRI gel dosimetry in radiation therapy

    International Nuclear Information System (INIS)

    Baeck, S.Aa.J.

    1998-12-01

    Gel dosimetry was used together with magnetic resonance imaging (MRI) to measure three-dimensional absorbed dose distributions in radiation therapy. Two different dosimeters were studied: ferrous- and monomer gel, based on the principles of radiation-induced oxidation and polymerisation, respectively. Single clinical electron and photon beams were evaluated and gel dose distributions were mainly within 2% of conventional detector results. The ferrous-gel was also used for clinical proton beams. A decrease in signal per absorbed dose was found close to the end of the range of the protons (15-20%). This effect was explained as a linear energy transfer dependence, further supported with Monte Carlo simulations. A method for analysing and comparing data from treatment planning system (TPS) and gel measurements was developed. The method enables a new pixel by pixel evaluation, isodose comparison and dose volume histogram verification. Two standard clinical radiation therapy procedures were examined using the developed TPS verification method. The treatment regimes included several beams of different radiation qualities. The TPS calculated data were in very good agreement with the dose distribution measured by the ferrous-gel. However, in a beam abutment region, larger dose difference was found. Beam adjustment errors and a minor TPS underestimation of the lateral scatter contribution outside the primary electron beam may explain the discrepancy. The overall uncertainty in the ferrous-gel dose determination was considerably reduced using an optimised MRI acquisition protocol and a new MRI scanner. The relative dose uncertainty was found to be better than 3.3% for all dose levels (95% confidence level). Using the method developed for comparing measured gel data with calculated treatment plans, the gel dosimetry method was proven to be a useful tool for radiation treatment planning verification

  9. Implementation of MRI gel dosimetry in radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Baeck, S.Aa.J

    1998-12-01

    Gel dosimetry was used together with magnetic resonance imaging (MRI) to measure three-dimensional absorbed dose distributions in radiation therapy. Two different dosimeters were studied: ferrous- and monomer gel, based on the principles of radiation-induced oxidation and polymerisation, respectively. Single clinical electron and photon beams were evaluated and gel dose distributions were mainly within 2% of conventional detector results. The ferrous-gel was also used for clinical proton beams. A decrease in signal per absorbed dose was found close to the end of the range of the protons (15-20%). This effect was explained as a linear energy transfer dependence, further supported with Monte Carlo simulations. A method for analysing and comparing data from treatment planning system (TPS) and gel measurements was developed. The method enables a new pixel by pixel evaluation, isodose comparison and dose volume histogram verification. Two standard clinical radiation therapy procedures were examined using the developed TPS verification method. The treatment regimes included several beams of different radiation qualities. The TPS calculated data were in very good agreement with the dose distribution measured by the ferrous-gel. However, in a beam abutment region, larger dose difference was found. Beam adjustment errors and a minor TPS underestimation of the lateral scatter contribution outside the primary electron beam may explain the discrepancy. The overall uncertainty in the ferrous-gel dose determination was considerably reduced using an optimised MRI acquisition protocol and a new MRI scanner. The relative dose uncertainty was found to be better than 3.3% for all dose levels (95% confidence level). Using the method developed for comparing measured gel data with calculated treatment plans, the gel dosimetry method was proven to be a useful tool for radiation treatment planning verification 103 refs, 20 figs, 6 tabs

  10. Effects of electron beam parameters and velocity spread on radio frequency output of a photonic band gap cavity gyrotron oscillator

    Science.gov (United States)

    Singh, Ashutosh; Jain, P. K.

    2015-09-01

    In this paper, the effects of electron beam parameters and velocity spread on the RF behavior of a metallic photonic band gap (PBG) cavity gyrotron operating at 35 GHz with TE041-like mode have been theoretically demonstrated. PBG cavity is used here to achieve a single mode operation of the overmoded cavity. The nonlinear time-dependent multimode analysis has been used to observe the beam-wave interaction behavior of the PBG cavity gyrotron, and a commercially available PIC code "CST Particle Studio" has been reconfigured to obtain 3D simulation results in order to validate the analytical values. The output power for this typical PBG gyrotron has been obtained ˜108 kW with ˜15.5% efficiency in a well confined TE041-like mode, while all other competing modes have significantly low values of power output. The output power and efficiency of a gyrotron depend highly on the electron beam parameters and velocity spread. The influence of several electron beam parameters, e.g., beam voltage, beam current, beam velocity pitch factor, and DC magnetic field, on the PBG gyrotron operations has been investigated. This study would be helpful in optimising the electron beam parameters and estimating accurate RF output power of the high frequency PBG cavity based gyrotron oscillators.

  11. Effects of electron beam parameters and velocity spread on radio frequency output of a photonic band gap cavity gyrotron oscillator

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Ashutosh, E-mail: asingh.rs.ece@iitbhu.ac.in [Faculty of Physical Sciences, Institute of Natural Sciences and Humanities, Shri Ramswaroop Memorial University, Lucknow-Deva Road, Uttar Pradesh 225003 (India); Center of Research in Microwave Tubes, Department of Electronics Engineering, Indian Institute of Technology (Banaras Hindu University), Varanasi 221005 (India); Jain, P. K. [Center of Research in Microwave Tubes, Department of Electronics Engineering, Indian Institute of Technology (Banaras Hindu University), Varanasi 221005 (India)

    2015-09-15

    In this paper, the effects of electron beam parameters and velocity spread on the RF behavior of a metallic photonic band gap (PBG) cavity gyrotron operating at 35 GHz with TE{sub 041}–like mode have been theoretically demonstrated. PBG cavity is used here to achieve a single mode operation of the overmoded cavity. The nonlinear time-dependent multimode analysis has been used to observe the beam-wave interaction behavior of the PBG cavity gyrotron, and a commercially available PIC code “CST Particle Studio” has been reconfigured to obtain 3D simulation results in order to validate the analytical values. The output power for this typical PBG gyrotron has been obtained ∼108 kW with ∼15.5% efficiency in a well confined TE{sub 041}–like mode, while all other competing modes have significantly low values of power output. The output power and efficiency of a gyrotron depend highly on the electron beam parameters and velocity spread. The influence of several electron beam parameters, e.g., beam voltage, beam current, beam velocity pitch factor, and DC magnetic field, on the PBG gyrotron operations has been investigated. This study would be helpful in optimising the electron beam parameters and estimating accurate RF output power of the high frequency PBG cavity based gyrotron oscillators.

  12. Blends of conjugated rigid-rod polymers: Novel supramolecular materials for electronics, optoelectronics and photonics

    Energy Technology Data Exchange (ETDEWEB)

    Jenekhe, S.A. [Univ. of Rochester, NY (United States)

    1996-12-31

    Selected examples of binary blends of conjugated polymers will be presented to illustrate the vast scope of their supramolecular structures and electronic, optical, nonlinear optical, and optoelectronic properties.

  13. A Deterministic Electron, Photon, Proton and Heavy Ion Radiation Transport Suite for the Study of the Jovian System

    Science.gov (United States)

    Norman, Ryan B.; Badavi, Francis F.; Blattnig, Steve R.; Atwell, William

    2011-01-01

    A deterministic suite of radiation transport codes, developed at NASA Langley Research Center (LaRC), which describe the transport of electrons, photons, protons, and heavy ions in condensed media is used to simulate exposures from spectral distributions typical of electrons, protons and carbon-oxygen-sulfur (C-O-S) trapped heavy ions in the Jovian radiation environment. The particle transport suite consists of a coupled electron and photon deterministic transport algorithm (CEPTRN) and a coupled light particle and heavy ion deterministic transport algorithm (HZETRN). The primary purpose for the development of the transport suite is to provide a means for the spacecraft design community to rapidly perform numerous repetitive calculations essential for electron, proton and heavy ion radiation exposure assessments in complex space structures. In this paper, the radiation environment of the Galilean satellite Europa is used as a representative boundary condition to show the capabilities of the transport suite. While the transport suite can directly access the output electron spectra of the Jovian environment as generated by the Jet Propulsion Laboratory (JPL) Galileo Interim Radiation Electron (GIRE) model of 2003; for the sake of relevance to the upcoming Europa Jupiter System Mission (EJSM), the 105 days at Europa mission fluence energy spectra provided by JPL is used to produce the corresponding dose-depth curve in silicon behind an aluminum shield of 100 mils ( 0.7 g/sq cm). The transport suite can also accept ray-traced thickness files from a computer-aided design (CAD) package and calculate the total ionizing dose (TID) at a specific target point. In that regard, using a low-fidelity CAD model of the Galileo probe, the transport suite was verified by comparing with Monte Carlo (MC) simulations for orbits JOI--J35 of the Galileo extended mission (1996-2001). For the upcoming EJSM mission with a potential launch date of 2020, the transport suite is used to compute

  14. Study of the discovery potential for hidden photon emission at future electron scattering fixed-target experiments

    Science.gov (United States)

    Beranek, T.; Vanderhaeghen, M.

    2014-03-01

    Recently, electron scattering fixed-target experiments came into focus to search for U(1) extensions of the Standard Model of particle physics at low energies. These extensions are motivated from anomalies in astrophysical observations as well as from deviations from Standard Model predictions, such as the discrepancy between the experimental and theoretical determinations of the anomalous magnetic moment of the muon. In such U(1) extensions, a new, light messenger particle γ', the hidden photon, couples to the hidden sector as well as to the electromagnetic current of the Standard Model by kinetic mixing, which allows for a search for this particle, e.g., in the invariant mass distribution of the process e(A ,Z)→e(A,Z)l+l-. In this process the hidden photon is emitted by bremsstrahlung and decays into a pair of Standard Model leptons. In this work we study the applicability of the Weizsäcker-Williams approximation to calculate the signal cross section of the process, which is widely used to design such experimental setups. Furthermore, we study the influence of the contribution from doubly virtual Compton scattering on experiments performed with proton targets. Based on a previous work, we investigate the discovery potential of future experimental setups at the Jefferson Lab and obtain a projected exclusion limit. We find that doubly virtual Compton scattering causes a 10% effect on the cross section for the kinematics of a planned experiment and therefore does not alter the obtained experimental reach significantly. In addition, we find that the Weizsäcker-Williams approximation can be applied to calculate the underlying cross sections in the kinematic range of most of the present and upcoming experiments, provided that the dependence on the energy and emission angle of the hidden photon is accounted for.

  15. Transverse momentum and centrality dependence of high-ptnon-photonic electron suppression in Au+Au collisions at $\\sqrt{s_{NN}}$= 200 GeV

    Energy Technology Data Exchange (ETDEWEB)

    Abelev, B.I.; Adams, J.; Aggarwal, M.M.; Ahammed, Z.; Amonett,J.; Anderson, B.D.; Anderson, M.; Arkhipkin, D.; Averichev, G.S.; Bai,Y.; Balewski, J.; Barannikova, O.; Barnby, L.S.; Baudot, J.; Bekele, S.; Belaga, V.V.; Bellingeri-Laurikainen, A.; Bellwied, R.; Benedosso, F.; Bhardwaj, S.; Bhasin, A.; Bhati, A.K.; Bichsel, H.; Bielcik, J.; Bielcikova, J.; Bland, L.C.; Blyth, S.-L.; Bonner, B.E.; Botje, M.; Bouchet, J.; Brandin, A.V.; Bravar, A.; Bystersky, M.; Cadman, R.V.; Cai,X.Z.; Caines, H.; Calderon de la Barca Sanchez, M.; Castillo, J.; Catu,O.; Cebra, D.; Chajecki, Z.; Chaloupka, P.; Chattopadhyay, S.; Chen,H.F.; Chen, J.H.; Cheng, J.; Cherney, M.; Chikanian, A.; Christie, W.; Coffin, J.P.; Cormier, T.M.; Cosentino, M.R.; Cramer, J.G.; Crawford,H.J.; Das, D.; Das, S.; Daugherity, M.; de Moura, M.M.; Dedovich, T.G.; DePhillips, M.; Derevschikov, A.A.; Didenko, L.; Dietel, T.; Djawotho,P.; Dogra, S.M.; Dong, W.J.; Dong, X.; Draper, J.E.; Du, F.; Dunin, V.B.; Dunlop, J.C.; Dutta Mazumdar, M.R.; Eckardt, V.; Edwards, W.R.; Efimov,L.G.; Emelianov, V.; Engelage, J.; Eppley, G.; Erazmus, B.; Estienne, M.; Fachini, P.; Fatemi, R.; Fedorisin, J.; Filimonov, K.; Filip, P.; Finch,E.; Fine, V.; Fisyak, Y.; Fu, J.; Gagliardi, C.A.; Gaillard, L.; Ganti,M.S.; Ghazikhanian, V.; Ghosh, P.; Gonzalez, J.S.; Gorbunov, Y.G.; Gos,H.; Grebenyuk, O.; Grosnick, D.; Guertin, S.M.; Guimaraes, K.S.F.F.; Guo,Y.; Gupta, N.; Gutierrez, T.D.; Haag, B.; Hallman, T.J.; Hamed, A.; Harris, J.W.; He, W.; Heinz, M.; Henry, T.W.; Hepplemann, S.; Hippolyte,B.; Hirsch, A.; Hjort, E.; Hoffman, A.M.; Hoffmann, G.W.; Horner, M.J.; Huang, H.Z.; Huang, S.L.; Hughes, E.W.; Humanic, T.J.; Igo, G.; Jacobs,P.; Jacobs, W.W.; Jakl, P.; Jia, F.; Jiang, H.; Jones, P.G.; Judd, E.G.; Kabana, S.; Kang, K.; Kapitan, J.; Kaplan, M.; Keane, D.; Kechechyan, A.; Khodyrev, V.Yu.; Kim, B.C.; Kiryluk, J.; Kisiel, A.; Kislov, E.M.; Klein,S.R.; Kocoloski, A.; Koetke, D.D.; et al.

    2006-07-11

    The STAR collaboration at RHIC reports measurements of theinclusive yield of non-photonic electrons, which arise dominantly fromsemi-leptonic decays of heavy flavor mesons, over a broad range oftransverse momenta (1.2photonic electron yieldexhibits unexpectedly large suppression in central AuAu collisions athigh pt, suggesting substantial heavy quark energy loss at RHIC. Thecentrality and \\pt dependences of the suppression provide constraints ontheoretical models of suppression.

  16. The application of Monte Carlo method to electron and photon beams transport; Zastosowanie metody Monte Carlo do analizy transportu elektronow i fotonow

    Energy Technology Data Exchange (ETDEWEB)

    Zychor, I. [Soltan Inst. for Nuclear Studies, Otwock-Swierk (Poland)

    1994-12-31

    The application of a Monte Carlo method to study a transport in matter of electron and photon beams is presented, especially for electrons with energies up to 18 MeV. The SHOWME Monte Carlo code, a modified version of GEANT3 code, was used on the CONVEX C3210 computer at Swierk. It was assumed that an electron beam is mono directional and monoenergetic. Arbitrary user-defined, complex geometries made of any element or material can be used in calculation. All principal phenomena occurring when electron beam penetrates the matter are taken into account. The use of calculation for a therapeutic electron beam collimation is presented. (author). 20 refs, 29 figs.

  17. Laser-driven electron beam generation for secondary photon sources with few terawatt laser pulses

    Science.gov (United States)

    Bohacek, K.; Chaulagain, U.; Horny, V.; Kozlova, M.; Krus, M.; Nejdl, J.

    2017-05-01

    Relativistic electron beams accelerated by laser wakefield have the ability to serve as sources of collimated, point-like and femtosecond X-ray radiation. Experimental conditions for generation of stable quasi-monoenergetic electron bunches using a femtosecond few-terawatt laser pulse (600 mJ, 50 fs) were investigated as they are crucial for generation of stable betatron radiation and X-ray pulses from inverse Compton scattering. A mixture of helium with argon, and helium with an admixture of synthetic air were tested for this purpose using different backing pressures and the obtained results are compared. The approach to use synthetic air was previously proven to stabilize the energy and energy spread of the generated electron beams at the given laser power. The accelerator was operated in nonlinear regime with forced self-injection and resulted in the generation of stable relativistic electron beams with an energy of tens of MeV and betatron X-ray radiation was generated in the keV range. A razor blade was tested to create a steep density gradient in order to improve the stability of electron injection and to increase the total electron bunch charge. It was proven that the stable electron and X-ray source can be built at small-scale facilities, which readily opens possibilities for various applications due to availability of such few-terawatt laser systems in many laboratories around the world.

  18. Measuring $\\sigma(e^+ e^- \\to hadrons)$ with Tagged Photons at Electron Positron Colliders

    CERN Document Server

    Kühn, J H

    2001-01-01

    A Monte Carlo generator has been constructed to simulate the reaction e+ e- --> gamma + 2 pions and gamma + 4 pions, where the photon is assumed to be observed in the detector. Predictions are presented for cms energies of 1GeV, 3GeV and 10GeV, corresponding to the energies of DAPHNE, BEBC and of B-meson factories. The event rates are sufficiently high to allow for a precise measurement of R(Q^2) in the region of Q between approximately 1GeV and 2.5GeV. Estimates for the kinematic breaking of isospin relations between different channels as a consequence of the mass difference between charged and neutral pions are given.

  19. Consecutive Fragmentation Mechanisms of Protonated Ferulic Acid Probed by Infrared Multiple Photon Dissociation Spectroscopy and Electronic Structure Calculations

    Science.gov (United States)

    Martens, Sabrina M.; Marta, Rick A.; Martens, Jonathan K.; McMahon, Terry B.

    2012-10-01

    Protonated ferulic acid and its principle fragment ion have been characterized using infrared multiple photon dissociation spectroscopy and electronic structure calculations at the B3LYP/6-311 + G(d,p) level of theory. Due to its extensively conjugated structure, protonated ferulic acid is observed to yield three stable fragment ions in IRMPD experiments. It is proposed that two parallel fragmentation pathways of protonated ferulic acid are being observed. The first pathway involves proton transfer, resulting in the loss of water and subsequently carbon monoxide, producing fragment ions m/z 177 and 149, respectively. Optimization of m/z 177 yields a species containing an acylium group, which is supported by a diagnostic peak in the IRMPD spectrum at 2168 cm-1. The second pathway involves an alternate proton transfer leading to loss of methanol and rearrangement to a five-membered ring.

  20. Status of the Development of Superconducting Undulators for Storage Rings and Free Electron Lasers at the Advanced Photon Source

    Energy Technology Data Exchange (ETDEWEB)

    Ivanyushenkov, Y.; Doose, C.; Fuerst, J.; Harkay, K.; Hasse, Q.; Kasa, M.; Shiroyanagi, Y.; Skiadopoulos, D.; Trakhtenberg, E.; Gluskin, E.; Emma, P.

    2017-06-01

    Development of superconducting undulator (SCU) technology continues at the Advanced Photon Source (APS). The experience of building and successful operating the first short-length, 16-mm period length superconducting undulator SCU0 paved the way for a 1-m long, 18-mm period device— SCU18-1— which has been in operation since May 2015. The APS SCU team has also built and tested a 1.5-m long, 21-mm period length undulator as a part of the LCLS SCU R&D program, aimed at demonstration of SCU technology availability for free electron lasers. This undulator successfully achieved all the requirements including a phase error of 5° RMS. Our team has recently completed one more 1-m long, 18-mm period length undulator— SCU18-2— that is replacing the SCU0. We are also working on a helical SCU for the APS. The status of these projects will be presented.

  1. Comparison of deep inelastic electron-photon scattering data with the HERWIG and PHOJET Monte Carlo models

    CERN Document Server

    Achard, P.; Braccini, S.; Chamizo, M.; Cowan, G.; de Roeck, A.; Field, J.H.; Finch, A.J.; Lin, C.H.; Lauber, J.A.; Lehto, M.H.; Kienzle-Focacci, M.N.; Miller, D.J.; Nisius, R.; Saremi, S.; Soldner-Rembold, S.; Surrow, B.; Taylor, R.J.; Wadhwa, M.; Wright, A.E.

    2002-01-01

    Deep inelastic electron-photon scattering is studied in the $Q^2$ range from 1.2 to 30 GeV$^2$ using the LEP1 data taken with the ALEPH, L3 and OPAL detectors at centre-of-mass energies close to the mass of the Z boson. Distributions of the measured hadronic final state are corrected to the hadron level and compared to the predictions of the HERWIG and PHOJET Monte Carlo models. For large regions in most of the distributions studied the results of the different experiments agree with one another. However, significant differences are found between the data and the models. Therefore the combined LEP data serve as an important input to improve on the Monte Carlo models.

  2. Two-Photon Exchange Effects in Elastic Electron-Proton Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Myriam James [Argonne National Lab. (ANL), Argonne, IL (United States)

    2013-08-01

    Two methods, Rosenbluth separation and polarization transfer, can be used to extract the proton form factor ratio μp GEp/GMp, but they do not yield the same results. It is thought that the disagreement is due to two photon exchange corrections to the differential cross sections. High precision proton Rosenbluth extractions were carried out at 102 kinematics points spanning 16 values of momentum transfer Q2, from 0.40 to 5.76 GeV2. Reduced cross sections were found to 1.1% or better for Q2 less than 3 GeV2 increasing to 4% at 5.76 GeV2 The form factor ratios were determined to 1:5-3% for Q2 < 1.5 GeV2, increasing to 9% by 3 GeV2 and rapidly above. Our data agrees with prior Rosenbluth, improving upon it the 1.0 - 2.0 GeV2 range to conclusively show a separation from polarization transfer where it had not been certain before. In addition, reduced cross sections at each Q2 were tested for nonlinearity in the angular variable. Such a departure from linearity would be a signature of two photon exchange effects, and prior data had not been sufficiently precise to show nonzero curvature. Our data begins to hint at negative curvature but does not yet show a significant departure from zero.

  3. Monolithic integration of photonic and electronic circuits in a CMOS process

    Science.gov (United States)

    Mekis, Attila; Abdalla, Sherif; Analui, Behnam; Gloeckner, Steffen; Guckenberger, Andrew; Koumans, Roger; Kucharski, Daniel; Liang, Yi; Masini, Gianlorenzo; Mirsaidi, Sina; Narasimha, Adithyaram; Pinguet, Thierry; Sadagopan, Vikram; Welch, Brian; White, Joe; Witzens, Jeremy

    2008-02-01

    We present our approach to a low-cost, highly scalable opto-electronic integration platform based on a commercial CMOS process. In this talk, we detail the performance of the device library elements and highlight performance trade-offs encountered in monolithically integrating optical and electronic circuits. We describe an opto-electronic integrated circuit (OEIC) design toolkit modeled after the standard electronic design flow, which includes automated design rule checking (DRC) and layout-versus-schematic (LVS) checks covering all types of circuit elements. As an example of integration, we detail the design of a multi-channel transceiver chip with 10 Gbps/channel optical data transmission speed and report on its performance.

  4. Adjuvant hypofractionated radiation in carcinoma breast – Photon versus Electron: Comparison of treatment outcome

    Directory of Open Access Journals (Sweden)

    G Prameela Chelakkot

    2017-01-01

    Conclusion: Hypofractionation is an accepted cost-effective standard of care in adjuvant breast radiation. Single en face electron field is well tolerated, and 3DCRT planning ensures homogeneous chest wall coverage, respecting dose constraints to organs at risk.

  5. Linac-based isocentric electron-photon treatment of radically operated breast carcinoma with enhanced dose uniformity in the field gap area.

    Science.gov (United States)

    Tenhunen, Mikko; Nyman, Heidi; Strengell, Satu; Vaalavirta, Leila

    2009-10-01

    Isocentric treatment technique is a standard method in photon radiotherapy with the primary advantage of requiring only a single patient set-up procedure for multiple fields. However, in electron treatments the size of the standard applicators does not generally allow to use an isocentric treatment technique. In this work we have modified and dosimetrically tested electron applicators for isocentric treatments in combination with photons. An isocentric treatment technique with photons and electrons for postmastectomy radiation therapy (PMRT) has been developed with special emphasis on improving the dose uniformity in the field gap area. Standard electron applicators of two Varian Clinac 2100CD linear accelerators were shortened by 10cm allowing isocentric treatments of 90cmelectron fields. Shortened applicators were commissioned and configured for the electron calculation algorithm of the treatment planning system. The field arrangement of PMRT was modified by combining three photon field segments with different gaps and overlaps with the electron field to improve dose uniformity. The developed technique and two other methods for PMRT were compared with each other in the group of 20 patients. Depth dose characteristics of the shortened applicators remained unchanged from those of the standard applicators. Penumbrae were broadened by 0-3mm depending on electron energy and depth as the air gap was increased from 5cm (standard applicator at SSD=100cm) to 10cm (shortened applicator at SSD=95cm). The dose calculation performance of the modified applicators at 95cmelectron dose calculation algorithm of the treatment planning system (Varian Eclipse). The modified isocentric treatment technique for PMRT was superior than the traditional two-dimensional technique. However, with the tangential photon fields without electrons the even better dose uniformity within PTV could be achieved but with increased irradiation of healthy tissues (lung, heart, and contralateral breast

  6. Photon factory

    International Nuclear Information System (INIS)

    Tanaka, J.; Huke, K.; Chikawa, J.

    1985-01-01

    The Photon Factory (PF) was established on April 1, 1978 at KEK. The PF is a synchrotron radiation facility, which has a 2.5 GeV electron storage ring fully dedicated to the SR usage and a 2.5 GeV electron linac supplying electrons and positrons to the PF ring and the accumulation ring of TRISTAN (30 GeV electron-positron colliding machine). The PF consists of three departments, injector linac, light source, and instrumentation department. The facility is described

  7. Far above bandgap photonics: attosecond dynamics of highly excited electrons in materials

    Science.gov (United States)

    Chen, Cong; Tao, Zhensheng; Carr, Adra; Szilvási, Tibor; Keller, Mark; Mavrikakis, Manos; Murnane, Margaret M.; Kapteyn, Henry C.

    2017-05-01

    Tabletop-scale coherent EUV generated through high-harmonic generation (HHG) produces light in the form of an attosecond pulse train that uniquely combines characteristics of good energy resolution (≍100-300meV) with sub-fs time resolution. This makes HHG an ideal source for studying the fastest dynamics in materials. Furthermore, using angle-resolved photoemission spectroscopy (ARPES), it is possible to extract detailed information about electron dynamics over the entire Brillouin zone. In recently published work, we combined HHG with ARPES to identify a sub-femtosecond excited-state lifetime for the first time. Photoemission occurs as a three-step process: 1) An electron is photoexcited from the valence band to far above the Fermi energy; 2) it transports to the surface, and 3) it overcomes the work function and exits. If the electron is promoted into a highlyexcited unoccupied band in the material (as opposed to a free-electron-like state), we observe the electron emission lifetime to increase in a measurable way—the Ni band 22 eV above the Fermi level has a lifetime of 212+/-30 attoseconds. Furthermore, by comparing photoemission from Cu and Ni, we reveal the influence of attosecond-timescale electron screening vs scattering by the electrons near the fermi surface. This work for the first time demonstrates the relevance of attosecond spectroscopy to the study of intrinsic properties and band structure in materials, as opposed to the strong-field induced dynamics studied extensively to-date.

  8. A closed-form formulation for the build-up factor and absorbed energy for photons and electrons in the Compton energy range in Cartesian geometry

    International Nuclear Information System (INIS)

    Borges, Volnei; Vilhena, Marco Tullio; Fernandes, Julio Cesar Lombaldo

    2011-01-01

    In this work, we report on a closed-form formulation for the build-up factor and absorbed energy, in one and two dimensional Cartesian geometry for photons and electrons, in the Compton energy range. For the one-dimensional case we use the LTS N method, assuming the Klein-Nishina scattering kernel for the determination of the angular radiation intensity for photons. We apply the two-dimensional LTS N nodal solution for the averaged angular radiation evaluation for the two-dimensional case, using the Klein-Nishina kernel for photons and the Compton kernel for electrons. From the angular radiation intensity we construct a closed-form solution for the build-up factor and evaluate the absorbed energy. We present numerical simulations and comparisons against results from the literature. (author)

  9. A closed-form formulation for the build-up factor and absorbed energy for photons and electrons in the Compton energy range in Cartesian geometry

    Energy Technology Data Exchange (ETDEWEB)

    Borges, Volnei; Vilhena, Marco Tullio, E-mail: borges@ufrgs.b, E-mail: vilhena@pq.cnpq.b [Universidade Federal do Rio Grande do Sul (PROMEC/UFRGS), Porto Alegre, RS (Brazil). Programa de Pos-Graduacao em Engenharia Mecanica; Fernandes, Julio Cesar Lombaldo, E-mail: julio.lombaldo@ufrgs.b [Universidade Federal do Rio Grande do Sul (DMPA/UFRGS), Porto Alegre, RS (Brazil). Dept. de Matematica Pura e Aplicada. Programa de Pos Graduacao em Matematica Aplicada

    2011-07-01

    In this work, we report on a closed-form formulation for the build-up factor and absorbed energy, in one and two dimensional Cartesian geometry for photons and electrons, in the Compton energy range. For the one-dimensional case we use the LTS{sub N} method, assuming the Klein-Nishina scattering kernel for the determination of the angular radiation intensity for photons. We apply the two-dimensional LTS{sub N} nodal solution for the averaged angular radiation evaluation for the two-dimensional case, using the Klein-Nishina kernel for photons and the Compton kernel for electrons. From the angular radiation intensity we construct a closed-form solution for the build-up factor and evaluate the absorbed energy. We present numerical simulations and comparisons against results from the literature. (author)

  10. Postmastectomy radiotherapy of the chest wall. Comparison of electron-rotation technique and common tangential photon fields

    International Nuclear Information System (INIS)

    Hehr, T.; Classen, J.; Huth, M.; Durst, I.; Bamberg, M.; Budach, W.; Christ, G.

    2004-01-01

    electron-rotation technique (LRC 92%) or with the photon-based technique (LRC 89%; p = 0.9). A subgroup analysis of tumors resected with ''close margins'' showed a higher LRF rate of 25% after electron-beam-rotation irradiation (n = 180) compared to an LRF of 13% with tangential opposed 6-MV photon fields (n = 107; p < 0.05). Large primary tumors of ≥ 5 cm developed LRF in 29% of patients treated with electron-beam-rotation irradiation and in 17% of patients with photon-based irradiation (p = 0.1). Conclusion: in locally advanced breast cancer, the LRC after postmastectomy irradiation with both techniques is comparable with published data from randomized studies. The tangential opposed photon field technique seems to be beneficial after marginal resection (histopathologic ''close margins'') of the primary tumor. (orig.)

  11. Determination of the size and phase composition of silver nanoparticles in a gel film of bacterial cellulose by small-angle X-ray scattering, electron diffraction, and electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Volkov, V. V.; Klechkovskaya, V. V., E-mail: klechvv@ns.crys.ras.ru; Shtykova, E. V.; Dembo, K. A.; Arkharova, N. A.; Ivakin, G. I. [Russian Academy of Sciences, Shubnikov Institute of Crystallography (Russian Federation); Smyslov, R. Yu. [Russian Academy of Sciences, Institute of Macromolecular Compounds (Russian Federation)

    2009-03-15

    The nanoscale structural features in a composite (gel film of Acetobacter Xylinum cellulose with adsorbed silver nanoparticles, stabilized by N-polyvinylpyrrolidone) have been investigated by small-angle X-ray scattering. The size distributions of inhomogeneities in the porous structure of the cellulose matrix and the size distributions of silver nanoparticles in the composite have been determined. It is shown that the sizes of synthesized nanoparticles correlate with the sizes of inhomogeneities in the gel film. Particles of larger size (with radii up to 100 nm) have also been found. Electron microscopy of thin cross sections of a dried composite layer showed that large particles are located on the cellulose layer surface. Electron diffraction revealed a crystal structure of silver nanoparticles in the composite.

  12. Measurement of recoil photon polarisation in the electron-proton elastic scattering

    International Nuclear Information System (INIS)

    Buon, Jean

    1965-02-01

    This research thesis reports and discusses an experiment which aimed at checking the validity of the Born approximation at the first order in the elastic scattering of high energy electrons on protons. In this experiment, the recoil proton polarisation is measured in an elastic scattering of electrons with energy of 950 MeV and scattering at about 90 degrees in the mass centre system. The author describes the experimental installation, its operation and data collection, reports the analysis of photos and polarisation calculations and errors [fr

  13. Electron- and photon-induced plasmonic excitations in two-dimensional silver nanostructures

    Energy Technology Data Exchange (ETDEWEB)

    Hoang, C. V.; Rana, M. [International Center for Materials Nanoarchitectonics (MANA), National Institute for Materials Science, 1-1 Namiki, Tsukuba 305-0044 (Japan); Nagao, T., E-mail: Nagao.Tadaaki@nims.go.jp [International Center for Materials Nanoarchitectonics (MANA), National Institute for Materials Science, 1-1 Namiki, Tsukuba 305-0044 (Japan); CREST, Japan Science and Technology Agency, 4-1-8 Honcho, Kawaguchi, Saitama 332-0012 (Japan)

    2014-06-23

    Plasmons are the quasi particles of collective oscillations of electrons and form the basis of plasmonics and optical metamaterials. We combined electron spectroscopy and optical spectroscopy techniques to study plasmons in atomically smooth Ag films and in epitaxial Ag nanodisks to map the momentum-energy dispersion curves of the two-dimensional (2D) sheet plasmon and the quasi-2D plasmons to clarify the essential differences between them. Our experimental results combined with the results of numerical electromagnetic simulations showed that the bulk-like nature of the silver plasmon starts in layers that are only two atoms thick.

  14. XRAY applied program package for calculation of electron-photon fields in the energy range of 1-1000 keV

    International Nuclear Information System (INIS)

    Lappa, A.V.; Khadyeva, Z.M.; Burmistrov, D.S.; Vasil'ev, O.N.

    1990-01-01

    The package of applied XRAY programs is intended for calculating the linear and fluctuation characteristics of photon and electron radiation fields in heterogeneous medium within 1-1000 keV energy range. The XRAY program package consists of moduli written in FORTRAN-IV and data files. 9 refs

  15. Structural and magnetic properties of inverse opal photonic crystals studied by x-ray diffraction, scanning electron microscopy, and small-angle neutron scattering

    NARCIS (Netherlands)

    Grigoriev, S.V.; Napolskii, K.S.; Grigoryeva, N.A.; Vasilieva, A.V.; Mistonov, A.A.; Chernyshov, D.Y.; Petukhov, A.V.; Belov, D.V.; Eliseev, A.A.; Lukashin, A.V.; Tretyakov, Y.D.; Sinitskii, A.S.; Eckerlebe, H.

    2009-01-01

    The structural and magnetic properties of nickel inverse opal photonic crystal have been studied by complementary experimental techniques, including scanning electron microscopy, wide-angle and small-angle diffraction of synchrotron radiation, and polarized neutrons. The sample was fabricated by

  16. Comparison of measurements of absorbed dose to water using a water calorimeter and ionization chambers for clinical radiotherapy photon and electron beams

    International Nuclear Information System (INIS)

    Marles, A.E.M.

    1981-01-01

    With the development of the water calorimeter direct measurement of absorbed dose in water becomes possible. This could lead to the establishment of an absorbed dose rather than an exposure related standard for ionization chambers for high energy electrons and photons. In changing to an absorbed dose standard it is necessary to investigate the effect of different parameters, among which are the energy dependence, the air volume, wall thickness and material of the chamber. The effect of these parameters is experimentally studied and presented for several commercially available chambers and one experimental chamber, for photons up to 25 MV and electrons up to 20 MeV, using a water calorimeter as the absorbed dose standard and the most recent formalism to calculate the absorbed dose with ion chambers. For electron beams, the dose measured with the calorimeter was 1% lower than the dose calculated with the chambers, independent of beam energy and chamber. For photon beams, the absorbed dose measured with the calorimeter was 3.8% higher than the absorbed dose calculated from the chamber readings. Such differences were found to be chamber and energy independent. The results for the photons were found to be statistically different from the results with the electron beams. Such difference could not be attributed to a difference in the calorimeter response

  17. Relative electron density determination using a physics based parameterization of photon interactions in medical DECT

    NARCIS (Netherlands)

    van Abbema, Joanne K.; van Goethem, Marc-Jan; Greuter, Marcel J. W.; van der Schaaf, Arjen; Brandenburg, Sytze; van der Graaf, Emiel R.

    2015-01-01

    Radiotherapy and particle therapy treatment planning require accurate knowledge of the electron density and elemental composition of the tissues in the beam path to predict the local dose deposition. We describe a method for the analysis of dual energy computed tomography (DECT) images that provides

  18. Combining optics and SDN to enable true hybrid integration of electronic and photonic switching solutions

    DEFF Research Database (Denmark)

    Guelbenzu, Gonzalo; Miao, Wang; Ben-Itzhak, Yaniv

    2017-01-01

    We present two hybrid fabrics integrating optical and electronic switches with SDN, and a novel approach improving the scaling of fast optical switches. C-Share reroute flows through optical switches increasing network performance. E-WDM exploits the optical switch transparency by emulating...

  19. Evidence for resonance electron transfer in photon excited X-ray ...

    Indian Academy of Sciences (India)

    is also measured. The measured relative intensities are compared with the theoretical estimates of Aberg. Keywords. X-ray satellites; resonance electron transfer; crystal spectrometer. PACS Nos 32.30.Rj; 32.80.Hd; 78.70.En. 1. Introduction. When an atom ionized simultaneously in different shells de-excites, X-ray satellites.

  20. Electron and photon degradation in aluminum, gallium and boron doped float zone silicon solar cells

    Science.gov (United States)

    Rahilly, W. P.; Scott-Monck, J.; Anspaugh, B.; Locker, D.

    1976-01-01

    Solar cells fabricated from Al, Ga and B doped Lopex silicon over a range of resistivities were tested under varying conditions of 1 MeV electron fluence, light exposures and thermal cycling. Results indicate that Al and Ga can replace B as a P type dopant to yield improved solar cell performance.

  1. Green photonics

    International Nuclear Information System (INIS)

    Quan, Frederic

    2012-01-01

    Photonics, the broad merger of electronics with the optical sciences, encompasses such a wide swath of technology that its impact is almost universal in our everyday lives. This is a broad overview of some aspects of the industry and their contribution to the ‘green’ or environmental movement. The rationale for energy conservation is briefly discussed and the impact of photonics on our everyday lives and certain industries is described. Some opinions from industry are presented along with market estimates. References are provided to some of the most recent research in these areas. (review article)

  2. Current status of AlInN layers lattice-matched to GaN for photonics and electronics

    International Nuclear Information System (INIS)

    Butte, R; Carlin, J-F; Feltin, E; Gonschorek, M; Nicolay, S; Christmann, G; Simeonov, D; Castiglia, A; Dorsaz, J; Buehlmann, H J; Christopoulos, S; Hoegersthal, G Baldassarri Hoeger von; Grundy, A J D; Mosca, M; Pinquier, C; Py, M A; Demangeot, F; Frandon, J; Lagoudakis, P G; Baumberg, J J; Grandjean, N

    2007-01-01

    We report on the current properties of Al 1-x In x N (x ∼ 0.18) layers lattice-matched (LM) to GaN and their specific use to realize nearly strain-free structures for photonic and electronic applications. Following a literature survey of the general properties of AlInN layers, structural and optical properties of thin state-of-the-art AlInN layers LM to GaN are described showing that despite improved structural properties these layers are still characterized by a typical background donor concentration of (1-5) x 10 18 cm -3 and a large Stokes shift (∼800 meV) between luminescence and absorption edge. The use of these AlInN layers LM to GaN is then exemplified through the properties of GaN/AlInN multiple quantum wells (QWs) suitable for near-infrared intersubband applications. A built-in electric field of 3.64 MV cm -1 solely due to spontaneous polarization is deduced from photoluminescence measurements carried out on strain-free single QW heterostructures, a value in good agreement with that deduced from theoretical calculation. Other potentialities regarding optoelectronics are demonstrated through the successful realization of crack-free highly reflective AlInN/GaN distributed Bragg reflectors (R > 99%) and high quality factor microcavities (Q > 2800) likely to be of high interest for short wavelength vertical light emitting devices and fundamental studies on the strong coupling regime between excitons and cavity photons. In this respect, room temperature (RT) lasing of a LM AlInN/GaN vertical cavity surface emitting laser under optical pumping is reported. A description of the selective lateral oxidation of AlInN layers for current confinement in nitride-based light emitting devices and the selective chemical etching of oxidized AlInN layers is also given. Finally, the characterization of LM AlInN/GaN heterojunctions will reveal the potential of such a system for the fabrication of high electron mobility transistors through the report of a high two

  3. Dosimetric evaluation of the Fricke gel dosimeter using the spectrophotometric technique for application in electron and neutron dosimetry; Avaliacao dosimetrica da solucao Fricke gel usando a tecnica de espectrofotometria para aplicacao na dosimetria de eletrons e neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Mangueira, Thyago Fressatti [Instituto de Pesquisas Energeticas e Nucleares (GMR/IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Metrologia das Radiacoes

    2011-07-01

    The main dosimetric characteristics of the Fricke Xylenol Gel (FXG) solution were established for further application in the measurement of dose distribution of clinical electron fields. The dose-response curves of the FXG in a thermal neutron field were also evaluated for application in Boron Neutron Capture Therapy (BNCT) and industrial electron fields. The standard reading technique was the spectrophotometry. For clinical fields the intra and inter-batch reproducibility of FXG solution are better than 1.4% and 5.1%, respectively. The optical response presents a linear behavior for doses ranging from 0.2 to 40 Gy independently of the electron energy and the dose rate in the studied ranges. Due to the effects of the FXG natural oxidation, the optimum elapsed time between FXG preparation and irradiation was established as 24h. The behavior of the dose-response curve does not change the obtained absorbance values relative to the non-irradiated dosimeter response during the studied period. The dose-response curve to industrial electron beam presented an exponential decreasing behavior. The optical response to thermal neutrons beam presented a linear behavior for the studied dose range. According to the obtained results to the different radiation fields studied it was not observed changes in the wavelength of the typical bands of the absorption spectrum radiation induced. Additional tests were performed with FXG solution to verify the viability and application of FXG dosimetry on intracavitary brachytherapy using digital photographic imaging. The excellent performance of the FXG dosimeter indicates that this dosimeter may be applied to tri-dimensional dose evaluation in radiotherapy treatments using electrons and neutron beams. (author)

  4. Hydrogen production by Tuning the Photonic Band Gap with the Electronic Band Gap of TiO2

    Science.gov (United States)

    Waterhouse, G. I. N.; Wahab, A. K.; Al-Oufi, M.; Jovic, V.; Anjum, D. H.; Sun-Waterhouse, D.; Llorca, J.; Idriss, H.

    2013-01-01

    Tuning the photonic band gap (PBG) to the electronic band gap (EBG) of Au/TiO2 catalysts resulted in considerable enhancement of the photocatalytic water splitting to hydrogen under direct sunlight. Au/TiO2 (PBG-357 nm) photocatalyst exhibited superior photocatalytic performance under both UV and sunlight compared to the Au/TiO2 (PBG-585 nm) photocatalyst and both are higher than Au/TiO2 without the 3 dimensionally ordered macro-porous structure materials. The very high photocatalytic activity is attributed to suppression of a fraction of electron-hole recombination route due to the co-incidence of the PBG with the EBG of TiO2 These materials that maintain their activity with very small amount of sacrificial agents (down to 0.5 vol.% of ethanol) are poised to find direct applications because of their high activity, low cost of the process, simplicity and stability. PMID:24108361

  5. Intraoperative electron beam therapy and external photon beam therapy with lumpectomy as primary treatment for early breast cancer

    International Nuclear Information System (INIS)

    Dobelbower, R.R.; Merrick, H.W.; Eltaki, A.; Bronn, D.G.

    1989-01-01

    Between 1984 and 1988, seven women with breast cancer were treated with intraoperative electron beam therapy (IOEBT). All patients were Caucasian. Patient age ranged from 37 to 62 (median 53) years. Histopathology was infiltrating duct carcinoma (6/7) or medullary carcinoma (1/7). Four tumors were staged T1 N0 MO, one T1 N1 MO, one T2 N1 MO, and one lesion was recurrent. At the time of primary lumpectomy or axillary node dissection, a dose of 10 or 15 Gy IOEBT was administered to the tumor bed with 6 or 9 MeV electrons through the lumpectomy wound. All patients received 45 or 50 Gy over five to six weeks with 6 MV photons to the breast and, in four patients, to the regional nodes. Three patients received adjuvant chemotherapy and tamoxifen. No post-operative complications were observed. All patients are alive as of August, 1989, with no evidence of recurrent disease. Excellent cosmesis is the rule. Clinical and technical aspects of treatment are presented along with the rationale for the use of IOEBT in the primary definitive radiotherapeutic management of early breast cancer

  6. Probabilities of Bremsstrahlung Emission of Photons at Low-Energy Electron-Nuclear Collisions in a Magnetic Field

    Science.gov (United States)

    Koryagin, S. A.; Balandin, I. A.

    2017-08-01

    We consider quantum-mechanical probabilities of bremsstrahlung of photons in the case of low-energy Coulomb collisions in a magnetic field, where the scattering center so perturbs the state of the incident electron that the motion of the latter becomes quasi-bound. Quantum formulas for the spectral power of bremsstrahlung radiation are obtained from the classical formulas by replacing the Fourier amplitudes of the particle velocity with matrix elements of the velocity operator for wave functions, which are normalized by the condition of a unit flux being incident on the nucleus (or an equivalent outgoing flux), with summation over finite Landau levels and quantized values of the impact parameter. Equivalent forms of the specified matrix elements, which are expressed in terms of the Coulomb field and annihilation/creation operators for the eigenfunctions of the operator of the squared impact parameter, are presented. The obtained presentations for the spectral power of bremsstrahlung radiation in the case of quasi-bound electron motion allow one to translate the results of calculating this value in the classical limit to the quantum case, which is typical of white dwarfs with the strongest magnetic fields.

  7. gel template method

    Indian Academy of Sciences (India)

    TiO2 nanotubes have been synthesized by sol–gel template method using alumina membrane. Scanning electron microscopy (SEM), transmission electron microscopy (TEM), Raman spectroscopy, UV absorption spectrum and X-ray diffraction techniques have been used to investigate the structure, morphology and optical ...

  8. Results of mixed photon-electron therapy in early glottic cancer

    International Nuclear Information System (INIS)

    Skolyszewski, J.; Reinfuss, M.; Rzepecki, W.

    1989-01-01

    The results of mixed photo-electron therapy in 85 patients with early glottic cancer are presented. 85% of the patients were in poor general condition. All patients received radiation to a single lateral laryngeal field of 6 X 6 to 8 X 8 cm 2 and the dose of 64 Gy to 70 Gy in 6 to 7 weeks. Half of the dose was delivered with a telecobalt unit and half with 15 MeV electrons. 78.8% patients (67/85) survived without evidence of malignancy for three years after the radiation therapy alone, and 5 patients survived after salvage surgery. The overall crude survival rate was 84.7% at three years. Three-year survival rates without evidence of malignancy were 91.5% in stage I and 69.2% in stage II

  9. Generalized Fokker-Planck theory for electron and photon transport in biological tissues: application to radiotherapy.

    Science.gov (United States)

    Olbrant, Edgar; Frank, Martin

    2010-12-01

    In this paper, we study a deterministic method for particle transport in biological tissues. The method is specifically developed for dose calculations in cancer therapy and for radiological imaging. Generalized Fokker-Planck (GFP) theory [Leakeas and Larsen, Nucl. Sci. Eng. 137 (2001), pp. 236-250] has been developed to improve the Fokker-Planck (FP) equation in cases where scattering is forward-peaked and where there is a sufficient amount of large-angle scattering. We compare grid-based numerical solutions to FP and GFP in realistic medical applications. First, electron dose calculations in heterogeneous parts of the human body are performed. Therefore, accurate electron scattering cross sections are included and their incorporation into our model is extensively described. Second, we solve GFP approximations of the radiative transport equation to investigate reflectance and transmittance of light in biological tissues. All results are compared with either Monte Carlo or discrete-ordinates transport solutions.

  10. Electron-photon coupling in semimetals in a high magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Mihaila, Bogdan [Los Alamos National Laboratory; Albers, Robert C [Los Alamos National Laboratory; Littlewood, Peter B [U. CAMBRIDGE/UK

    2009-01-01

    We consider the effect of electron-phonon coupling in semimetals in high magnetic fields, with regard to elastic modes that can lead to a redistribution of carriers between pockets. We show that in a clean three dimensional system, at each Landau level crossing, this leads to a discontinuity in the magnetostriction, and a divergent contribution to the elastic modulus. We estimate the magnitude of this effect in the group V semimetal Bismuth.

  11. Tale of two photons

    International Nuclear Information System (INIS)

    Anon.

    1994-01-01

    A very profitable spinoff from electron- positron collisions is two-photon physics. Rather than the electron and positron interacting directly via an exchanged photon, two virtual (transient) photons, one from each particle, get tangled up. With new electron-positron colliders appearing on the scene, a topical meeting on two-photon physics - 'From DAPHNE to LEP 200 and beyond' - held from 2-4 February in Paris, in the premises of the Ministry of Higher Education and Research, was particularly timely. Some 60 physicists, both experimentalists and theorists, participated, with some thirty speakers

  12. Characterization and optimization of an optical and electronic architecture for photon counting

    Science.gov (United States)

    Correa, M. del M.; Pérez, F. R.

    2018-04-01

    This work shows a time-domain method for the discrimination and digitization of pulses coming from optical detectors, considering the presence of electronic noise and afterpulsing. The developed signal processing scheme is based on a time-to-digital converter (TDC) and a voltage discriminator. After setting appropriate parameters for taking spectra, acquisition data was corrected by wavelength, intensity response function, and noise suppression. The performance of this scheme is discussed by its characterization as well as the comparison of its spectra to those obtained by an Ocean Optics HR4000 commercial reference.

  13. Monolithic integration of III-V nanostructures for electronic and photonic applications

    Science.gov (United States)

    Mayer, B.; Wirths, S.; Schmid, H.; Mauthe, S.; Convertino, C.; Baumgartner, Y.; Czornomaz, L.; Sousa, M.; Riel, H.; Moselund, K. E.

    2017-08-01

    We have recently developed a novel III-V integration scheme, where III-V material is grown directly on top of Si within oxide nanotubes or microcavities which control the geometry of nanostructures. This allows us to grow III-V material non-lattice matched on any crystalline orientation of Si, to grow arbitrary shapes as well as abrupt heterojunctions, and to gain more flexibility in tuning of composition. In this talk, applications for electronic devices such as heterojunction tunnel FETs and microcavity III-V lasers monolithically integrated on Si will be discussed along with an outlook for the future.

  14. Dosimetric evaluation of the Fricke gel dosimeter using the spectrophotometric technique for application in electron and neutron dosimetry; Avaliacao dosimetrica da solucao Fricke gel usando a tecnica de espectrofotometria para aplicacao na dosimentria de eletrons e neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Mangueira, Thyago Fressatti

    2009-07-01

    In this work the main dosimetric characteristics of the Fricke Xylenol Gel (FXG) solution were established for further application in the measurement of dose distribution of clinical electron fields. The dose-response curves of the FXG in a neutron field were also evaluated for the research in Boron Neutron Capture Therapy (BNCT) and industrial electron fields. The standard reading technique was the spectrophotometric. For the clinical field, the intra and inter-batch reproducibility are better than 1.4% and 5.1 %, respectively, the response presents a linear behavior for doses ranging from 0.2 to 40 Gy independently of the energy and the dose rate in the studied ranges. Due to the effects of the FXG natural oxidation, the optimum elapsed time between FXG preparation and irradiation was established as 24h period and the behavior of the dose-response curve of the FXG using the variation in the absorbance relative to the non-irradiated dosimeter as a basis during the whole studied period were not altered. The dose-response to the industrial electron beam presented an exponential decreasing behavior and the neutron beam for research in BNCT presented a linear behavior for the complete studied dose range. According to the obtained results for the different types of radiation studied for the FXG, there was no change in the position of the characteristic bands of the absorption spectrum due to the interaction of these radiation types. Additional tests were performed to determine the digital photographic imaging of FXG analyses viability and the application of FXG dosimetry on intracavitary brachytherapy. The good performance of the FXG dosimeter in the tests that were carried out indicates that this dosimeter may be applied to the tri-dimensional dose evaluation in radiotherapic treatments using electrons and neutron beams. (author)

  15. Ultra-high-throughput Production of III-V/Si Wafer for Electronic and Photonic Applications

    Science.gov (United States)

    Geum, Dae-Myeong; Park, Min-Su; Lim, Ju Young; Yang, Hyun-Duk; Song, Jin Dong; Kim, Chang Zoo; Yoon, Euijoon; Kim, Sanghyeon; Choi, Won Jun

    2016-02-01

    Si-based integrated circuits have been intensively developed over the past several decades through ultimate device scaling. However, the Si technology has reached the physical limitations of the scaling. These limitations have fuelled the search for alternative active materials (for transistors) and the introduction of optical interconnects (called “Si photonics”). A series of attempts to circumvent the Si technology limits are based on the use of III-V compound semiconductor due to their superior benefits, such as high electron mobility and direct bandgap. To use their physical properties on a Si platform, the formation of high-quality III-V films on the Si (III-V/Si) is the basic technology ; however, implementing this technology using a high-throughput process is not easy. Here, we report new concepts for an ultra-high-throughput heterogeneous integration of high-quality III-V films on the Si using the wafer bonding and epitaxial lift off (ELO) technique. We describe the ultra-fast ELO and also the re-use of the III-V donor wafer after III-V/Si formation. These approaches provide an ultra-high-throughput fabrication of III-V/Si substrates with a high-quality film, which leads to a dramatic cost reduction. As proof-of-concept devices, this paper demonstrates GaAs-based high electron mobility transistors (HEMTs), solar cells, and hetero-junction phototransistors on Si substrates.

  16. The photon collider at TESLA

    Czech Academy of Sciences Publication Activity Database

    Badelek, B.; Bloechinger, C.; Blümlein, J.; Boos, E.; Brinkman, R.; Burkhardt, H.; Bussey, P.; Carimalo, C.; Chýla, Jiří; Ciftci, A.K.

    2004-01-01

    Roč. 19, č. 30 (2004), s. 5097-5186 ISSN 0217-751X Institutional research plan: CEZ:AV0Z1010920 Keywords : photon collider * linear collider * gamma-gamma * photon-photon * photon electron * Compton scattering Subject RIV: BF - Elementary Particles and High Energy Physics Impact factor: 1.054, year: 2004

  17. Photonic Potential of Haloarchaeal Pigment Bacteriorhodopsin for Future Electronics: A Review.

    Science.gov (United States)

    Ashwini, Ravi; Vijayanand, S; Hemapriya, J

    2017-08-01

    Haloarchaea are known for its adaptation in extreme saline environment. Halophilic archaea produces carotenoid pigments and proton pumps to protect them from extremes of salinity. Bacteriorhodopsin (bR) is a light-driven proton pump that resides in the membrane of haloarchaea Halobacterium salinarum. The photocycle of Bacteriorhodopsin passes through several states from K to O, finally liberating ATP for host's survival. Extensive studies on Bacteriorhodopsin photocycle has provided in depth knowledge on their sequential mechanism of converting solar energy into chemical energy inside the cell. This ability of Bacteriorhodopsin to harvest sunlight has now been experimented to exploit the unexplored and extensively available solar energy in various biotechnological applications. Currently, bacteriorhodopsin finds its importance in dye-sensitized solar cell (DSSC), logic gates (integrated circuits, IC's), optical switching, optical memories, storage devices (random access memory, RAM), biosensors, electronic sensors and optical microcavities. This review deals with the optical and electrical applications of the purple pigment Bacteriorhodopsin.

  18. Investigation of Electron Transfer-Based Photonic and Electro-Optic Materials and Devices

    Energy Technology Data Exchange (ETDEWEB)

    Bromenshenk, Jerry J; Abbott, Edwin H; Dickensheets, David; Donovan, Richard P; Hobbs, J D; Spangler, Lee; McGuirl, Michele A; Spangler, Charles; Rebane, Aleksander; Rosenburg, Edward; Schmidt, V H; Singel, David J

    2008-03-28

    Montana's state program began its sixth year in 2006. The project's research cluster focused on physical, chemical, and biological materials that exhibit unique electron-transfer properties. Our investigators have filed several patents and have also have established five spin-off businesses (3 MSU, 2 UM) and a research center (MT Tech). In addition, this project involved faculty and students at three campuses (MSU, UM, MT Tech) and has a number of under-represented students, including 10 women and 5 Native Americans. In 2006, there was an added emphasis on exporting seminars and speakers via the Internet from UM to Chief Dull Knife Community College, as well as work with the MT Department of Commerce to better educate our faculty regarding establishing small businesses, licensing and patent issues, and SBIR program opportunities.

  19. Electronic Properties of Tin and Bismuth from Angular Correlation of Annihilation Photons

    DEFF Research Database (Denmark)

    Mogensen, O.E.; Trumpy, Georg

    1969-01-01

    A linear slit setup has been used to obtain results of angular-correlation measurements in (a) tin single crystals in three orientations: [001], [100], and [110], (b) bismuth single crystals in four orientations: [111], [100], [1¯10], and [2¯1¯1], (c) solid and liquid tin and bismuth, and (d......) deformed bismuth. For both metals, the single-crystal angular-correlation curves lie near to the free-electron parabola. The tin curves show more anisotropy than the bismuth curves. An important result is the clear anisotropy found in the high-momentum part of the curves—the tails—for both metals. Little...... of the liquid-metal curves are smaller and of another form than the tails of polycrystalline curves; no Gaussian with only one adjustable constant factor can give a fit to both tails. No useful method for interpreting liquid-metal angular-correlation curves seems to exist. Two deformed bismuth samples gave...

  20. The ‘cutting away’ of potential secondary electron tracks explains the effects of beam size and detector wall density in small-field photon dosimetry

    Science.gov (United States)

    Khee Looe, Hui; Delfs, Björn; Poppinga, Daniela; Jiang, Ping; Harder, Dietrich; Poppe, Björn

    2018-01-01

    The well-known field-size dependent overresponse in small-field photon-beam dosimetry of solid-state detectors equipped with very thin sensitive volumes, such as the PTW microDiamond, cannot be caused by the photon and electron interactions within these sensitive layers because they are only a few micrometers thick. The alternative explanation is that their overresponse is caused by the combination of two effects, the modification of the secondary electron fluence profile (i) by a field size too small to warrant lateral secondary electron equilibrium and (ii) by the density-dependent electron ranges in the structural detector materials placed in front of or backing the sensitive layer. The present study aims at the numerical demonstration and visualization of this combined mechanism. The lateral fluence profiles of the secondary electrons hitting a 1 µm thick scoring layer were Monte-Carlo simulated by modelling their generation and transport in the upstream or downstream adjacent layers of thickness 0.6 mm and densities from 0.0012 to 3 g cm‑3, whose atomic composition was constantly kept water-like. The scoring layer/adjacent layer sandwich was placed in an infinite water phantom irradiated by circular 60Co, 6 MV and 15 MV photon beams with diameters from 3 to 40 mm. The interpretation starts from the ideal case of lateral secondary electron equilibrium, where the Fano theorem excludes any density effect. If the field size is then reduced, electron tracks potentially originating from source points outside the field border will then be numerically ‘cut away’. This geometrical effect reduces the secondary electron fluence at the field center, but the magnitude of this reduction also varies with the density-dependent electron ranges in the adjacent layers. This combined mechanism, which strongly depends on the photon spectrum, explains the field size and material density effect on the response of detectors with very thin sensitive layers used in small

  1. The FERMI@Elettra free-electron-laser source for coherent X-ray physics: photon properties, beam transport system, and applications

    Energy Technology Data Exchange (ETDEWEB)

    Allaria, Enrico; Callegari, Carlo; Cocco, Daniele; Fawley, William M.; Kiskinova, Maya; Masciovecchio, Claudio; Parmigiani, Fulvio

    2010-04-05

    FERMI@Elettra is comprised of two free electron lasers (FELs) that will generate short pulses (tau ~;; 25 to 200 fs) of highly coherent radiation in the XUV and soft X-ray region. The use of external laser seeding together with a harmonic upshift scheme to obtain short wavelengths will give FERMI@Elettra the capability to produce high quality, longitudinal coherent photon pulses. This capability together with the possibilities of temporal synchronization to external lasers and control of the output photon polarization will open new experimental opportunities not possible with currently available FELs. Here we report on the predicted radiation coherence properties and important configuration details of the photon beam transport system. We discuss the several experimental stations that will be available during initial operations in 2011, and we give a scientific perspective on possible experiments that can exploit the critical parameters of this new light source.

  2. Photonic crystals: towards nanoscale photonic devices

    National Research Council Canada - National Science Library

    Lourtioz, J.-M

    2005-01-01

    .... From this point of view, the emergence of photonic bandgap materials and photonic crystals at the end of the 1980s can be seen as a revenge to the benefit this time of optics and electromagnetism. In the same way as the periodicity of solid state crystals determines the energy bands and the conduction properties of electrons, the periodical structur...

  3. Simultaneous production of spin-polarized ions/electrons based on two-photon ionization of laser-ablated metallic atoms

    International Nuclear Information System (INIS)

    Nakajima, Takashi; Yonekura, Nobuaki; Matsuo, Yukari; Kobayashi, Tohru; Fukuyama, Yoshimitsu

    2003-01-01

    We demonstrate the simultaneous production of spin-polarized ions/electrons using two-color, two-photon ionization of laser-ablated metallic atoms. Specifically, we have applied the developed technique to laser-ablated Sr atoms, and found that the electron-spin polarization of Sr + ions, and accordingly, the spin polarization of photoelectrons is 64%±9%, which is in good agreement with the theoretical prediction we have recently reported [T. Nakajima and N. Yonekura, J. Chem. Phys. 117, 2112 (2002)]. Our experimental results open up a simple way toward the construction of a spin-polarized dual ion/electron source

  4. Preliminary Report on the Evaluation of an Electron-Positron Collider as a source of Monoenergetic Photons

    Energy Technology Data Exchange (ETDEWEB)

    Fast, James E.; Campbell, Luke W.

    2009-11-30

    Abstract Active interrogation methods are being investigated to detect shielded special nuclear material (SNM). These approaches utilize either neutron or photon beams to excite the SNM in concert with either neutron or gamma ray detectors to observe the stimulated emissions. The two primary methodologies with photon beams are photofission and nuclear resonance florescence (NRF). Photofission requires photons energies of 7-10 MeV while NRF requires photon energies around 2 MeV. For both techniques, photons that are not in the appropriate energy band, e.g. the low energy tail of a Bremsstrahlung photon beam, contribute unwanted additional radiation dose to cargo. Typically less than 10% of the photons are in the usable energy band. The additional photon production generates a commensurate amount of additional radiation dose in the source and target areas, impacting shielding requirements and/or dose to operators and equipment and at the expense of a similar increase in power consumption. Hence it is highly desirable to produce narrow energy (“monoenergetic”) photon beams with tunable energy in the range of ~2-20 MeV.

  5. Ion energy distributions from photon- and electron-stimulated desorption. II. The quasiclassical final state and reneutralization

    Science.gov (United States)

    Clinton, William L.; Pal, Sipra; Jutila, Ronald E.

    1987-09-01

    Franck-Condon overlap integrals are calculated to fit ion energy distributions (IED's) resulting from photon- or electron-stimulated desorption. The WKB or quasiclassical trajectory approximation is used to compute the final-state wave function. The final-state potential consists of a repulsive exponential and an image term. The calculated IED's compare well with those found previously using the reflection or classical trajectory approximation. Both methods agree well with a wide range of experimental IED's all of which are mildly asymmetric Gaussian functions of the ion energy. It is shown how these two approximations are related through the classical limit of the final-state wave function. In addition, the quasiclassical wave function is generalized to include an optical potential giving rise in a natural way to the reneutralization reduction factor. The Gaussian asymmetry in the IED's is usually to the high-energy side reflecting a ``normal'' exponential repulsion. However, in a few anomalous cases the Gaussian is skewed to the low-energy side of the IED peak. This anomaly cannot be explained by expected influences on the initial-state wave function such as anharmonicities. On the other hand, the reneutralization factor, when it predominates, provides a natural explanation for this effect. In addition, this reneutralization factor can cause significant shifts in the IED peak, away from the Franck-Condon peak.

  6. Development of a photon-counting capability for the electron-bombarded far-UV image sensor

    Science.gov (United States)

    Jenkins, Edward B.; Reale, Michael A.; Zucchino, Paul M.

    1999-11-01

    We have developed a video signal processing system to detect and store photoevents recorded by a magnetically focused, electron-bombarded CCD (EBCCD) image sensor of the type that flew on the Interstellar Medium Absorption Profile Spectrograph (IMAPS). The EBCCD represents a good alternative to detectors that use microchannel plates: the opaque photocathode is on a solid substrate which leads to a very uniform response with a high quantum efficiency. Our experience with sounding rocket missions has demonstrated that this image sensor can perform well in poor vacuum conditions. Previous uses of the EBCCD on IMAPS missions have worked with video signals that were accumulated in an analog fashion. To make the EBCCD more useful for viewing very faint images in the future, we have recently developed new circuitry to detect photoevents in real time and store them discretely. This photon-counting signal processing mode overcomes the CCD readout noise penalty that accumulates when many successive analog frames are added together. The new circuits also provide for an automatic, accurate subtraction of the CCD dark current pattern.

  7. Treatment planning comparison of electron arc therapy and photon intensity modulated radiotherapy for Askin's tumor of chest wall

    International Nuclear Information System (INIS)

    Jamema, Swamidas V.; Sharma, Pramod K.; Laskar, Siddhartha; Deshpande, Deepak D.; Shrivastava, Shyam K.

    2007-01-01

    Background and Purpose: A dosimetric study to quantitatively compare radiotherapy treatment plans for Askin's tumor using Electron Arc (EA) vs. photon Intensity Modulated Radiotherapy (IMRT). Materials and methods: Five patients treated with EA were included in this study. Treatment plans were generated for each patient using EA and IMRT. Plans were compared using dose volume histograms (DVH) of the Planning Target Volume (PTV) and Organs at Risk (OAR). Results: IMRT resulted in superior PTV coverage, and homogeneous dose distribution compared to EA. For EA, 92% of the PTV was covered to 85% of the dose compared to IMRT in which 96% was covered to 95% of the dose. V 107 that represents the hot spot within the PTV was more in IMRT compared to EA: 7.4(±2)% vs. 3(±0.5)%, respectively. With PTVs located close to the spinal cord (SC), the dose to SC was more with EA, whereas for PTVs located away from the SC, the dose to SC was more with IMRT. The cardiac dose profile was similar to that of SC. Ipsilateral lung received lower doses with IMRT while contralateral lung received higher dose with IMRT compared to EA. For non-OAR normal tissues, IMRT resulted in large volumes of low dose regions. Conclusions: IMRT resulted in superior PTV coverage and sparing of OAR compared to EA plans. Although IMRT seems to be superior to EA, one needs to keep in mind the volume of low dose regions associated with IMRT, especially while treating young children

  8. Studied by electron paramagnetic resonance (EPR) of polymethyl methacrylate (PMMA) irradiated with gamma photons from cobalt 60

    International Nuclear Information System (INIS)

    Jalali, Hajer

    2013-01-01

    Ionizing radiation is radiation able to deposit enough energy in the material through which they pass to create ionization. These ionizing radiations, when mastered, have many practical uses beneficial (areas of health, industry ...). Gamma rays are emitted by radioactive nuclei. The objective of our work is the study of polymethyl methacrylate (PMMA) irradiated by gamma photons from cobalt-60. To study the technique of radio spectroscopy (9 to 10Hz) electron paramagnetic resonance EPR is used. This technique is specific to characterize transient free radicals involved in chemical reactions such as oxidation, combustion, polymerization reactions ... We analyzed the EPR spectra three batch KS, EB, and JF our dosimeter according to the dose (high and low) and showed that the dosimetric response can be represented in exponential form (high dose) and linear form (low dose). We also studied the kinetics of decay of the EPR signal as a function of time (fading) and showed that the responses relating to stabilize after 20 min of irradiation.

  9. One-photon two-electron processes in helium: Unity and diversity

    International Nuclear Information System (INIS)

    Bouri, C.; Selles, P.; Malegat, L.; Kwato Njock, M.G.

    2007-01-01

    The ab initio HRM-SOW method has established itself as the ideally fit tool to explore the three-body dynamics of the helium atom close to its full break-up threshold. Accordingly, it is used here to perform a 'numerical experiment' designed to enlighten the relations between the various competing processes which may occur in the vicinity of the double ionization threshold, be it double excitation, excitation-ionization, or double ionization. More precisely, double ionization and ionization-excitation cross-sections are produced at 100 meV above the double ionization threshold. The latter, obtained up to as high a level as n=50, are in addition analyzed in terms of spherical and parabolic partial waves in the photo-electron frame. Based on these extensive data, we establish a continuity relation between ionization-excitation and double ionization appropriate to the near threshold region, confirm previous qualitative predictions regarding the dominant angular momentum achieved in these near threshold excitation processes, evidence the relation between ionized-excited and doubly excited states, and promote the partial parabolic ionization-excitation cross-sections as the optimal observation channels of doubly excited states

  10. An overview of the Boltzmann transport equation solution for neutrons, photons and electrons in cartesian geometry

    International Nuclear Information System (INIS)

    Rodriguez, Barbara D. do Amaral; Vilhena, Marco Tullio

    2009-01-01

    Questions regarding accuracy and efficiency of deterministic transport methods are still on our mind today, even with modern supercomputers. The most versatile and widely used deterministic methods are the P N approximation, the S N method (discrete ordinates method) and their variants. In the discrete ordinates (S N ) formulations of the transport equation, it is assumed that the linearized Boltzmann equation only holds for a set of distinct numerical values of the direction-of-motion variables. In this work, looking forward to confirm the capabilities of deterministic methods in obtaining accurate results, we present a general overview of deterministic methods to solve the Boltzmann transport equation for neutral and charged particles. First, we describe a review in the Laplace transform technique applied to S N two dimensional transport equation in a rectangular domain considering Compton scattering. Next, we solved the Fokker-Planck (FP) equation, an alternative approach for the Boltzmann transport equation, assuming a monoenergetic electron beam in a rectangular domain. The main idea relies on applying the P N approximation, a recent advance in the class of deterministic methods, in the angular variable, to the two dimensional Fokker-Planck equation and then applying the Laplace Transform in the spatial x-variable. Numerical results are given to illustrate the accuracy of deterministic methods presented. (author)

  11. Single-photon imaging

    CERN Document Server

    Seitz, Peter

    2011-01-01

    The acquisition and interpretation of images is a central capability in almost all scientific and technological domains. In particular, the acquisition of electromagnetic radiation, in the form of visible light, UV, infrared, X-ray, etc. is of enormous practical importance. The ultimate sensitivity in electronic imaging is the detection of individual photons. With this book, the first comprehensive review of all aspects of single-photon electronic imaging has been created. Topics include theoretical basics, semiconductor fabrication, single-photon detection principles, imager design and applications of different spectral domains. Today, the solid-state fabrication capabilities for several types of image sensors has advanced to a point, where uncoooled single-photon electronic imaging will soon become a consumer product. This book is giving a specialist´s view from different domains to the forthcoming “single-photon imaging” revolution. The various aspects of single-photon imaging are treated by internati...

  12. An identification of the soft polyelectrolyte gel-like layer on silica colloids using atomic force and electron microscopy.

    Science.gov (United States)

    Škvarla, Jiří; Škvarla, Juraj

    2017-10-01

    A procedure is introduced for measuring the radius of spherical colloid particles from the curvature of upper parts of their central cross-sectional profiles obtained by atomic force microscopy (AFM). To minimize the possible compression and displacement of the spheres, AFM is operated in a mode rendering a constant ultralow pN force on the tip. The procedure allows us to evaluate the mean radius of nearly monodisperse submicrometer spheres of silica in their natively hydrated state in aqueous electrolyte solutions, irrespective of whether they are coagulated or not. A variation in the volume (swelling degree) of layers delimited by the AFM mean radii of these spheres in KCl solutions and their invariable mean radius in vacuum is obtained that follows a scaling power law derived in polymer physics for swellable polyelectrolyte gels and deduced previously by us from coagulation tests. This supports our former suggestion about the existence of soft polyelectrolyte gel-like layer developed spontaneously around silica surfaces and colloids. We discuss this finding in the context of recent knowledge about the structure of the silica/water interface obtained from direct surface force measurements between macroscopic silica surfaces and from particle size measurements of silica colloids and highlight its importance for colloid chemistry and condensed mattter physics. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Analysis of the EBT3 Gafchromic film irradiated with 6 MV photons and 6 MeV electrons using reflective mode scanners.

    Science.gov (United States)

    Farah, Nicolas; Francis, Ziad; Abboud, Marie

    2014-09-01

    We explore in our study the effects of electrons and X-rays irradiations on the newest version of the Gafchromic EBT3 film. Experiments are performed using the Varian "TrueBeam 1.6" medical accelerator delivering 6 MV X-ray photons and 6 MeV electron beams as desired. The main interest is to compare the responses of EBT3 films exposed to two separate beams of electrons and photons, for radiation doses ranging up to 500 cGy. The analysis is done on a flatbed EPSON 10000 XL scanner and cross checked on a HP Scanjet 4850 scanner. Both scanners are used in reflection mode taking into account landscape and portrait scanning positions. After thorough verifications, the reflective scanning method can be used on EBT3 as an economic alternative to the transmission method which was also one of the goals of this study. A comparison is also done between single scan configuration including all samples in a single A4 (HP) or A3 (EPSON) format area and multiple scan procedure where each sample is scanned separately on its own. The images analyses are done using the ImageJ software. Results show significant influence of the scanning configuration but no significant differences between electron and photon irradiations for both single and multiple scan configurations. In conclusion, the film provides a reliable relative dose measurement method for electrons and photons irradiations in the medical field applications. Copyright © 2014 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  14. Photonic Crystals Towards Nanoscale Photonic Devices

    CERN Document Server

    Lourtioz, Jean-Michel; Berger, Vincent; Gérard, Jean-Michel; Maystre, Daniel; Tchelnokov, Alexis

    2005-01-01

    Just like the periodical crystalline potential in solid-state crystals determines their properties for the conduction of electrons, the periodical structuring of photonic crystals leads to envisioning the possibility of achieving a control of the photon flux in dielectric and metallic materials. The use of photonic crystals as a cage for storing, filtering or guiding light at the wavelength scale thus paves the way to the realisation of optical and optoelectronic devices with ultimate properties and dimensions. This should contribute toward meeting the demands for a greater miniaturisation that the processing of an ever increasing number of data requires. Photonic Crystals intends at providing students and researchers from different fields with the theoretical background needed for modelling photonic crystals and their optical properties, while at the same time presenting the large variety of devices, from optics to microwaves, where photonic crystals have found applications. As such, it aims at building brid...

  15. Photonic Crystals Towards Nanoscale Photonic Devices

    CERN Document Server

    Lourtioz, Jean-Michel; Berger, Vincent; Gérard, Jean-Michel; Maystre, Daniel; Tchelnokov, Alexei; Pagnoux, Dominique

    2008-01-01

    Just like the periodical crystalline potential in solid state crystals determines their properties for the conduction of electrons, the periodical structuring of photonic crystals leads to envisioning the possibility of achieving a control of the photon flux in dielectric and metallic materials. The use of photonic crystals as cages for storing, filtering or guiding light at the wavelength scale paves the way to the realization of optical and optoelectronic devices with ultimate properties and dimensions. This will contribute towards meeting the demands for greater miniaturization imposed by the processing of an ever increasing number of data. Photonic Crystals will provide students and researchers from different fields with the theoretical background required for modelling photonic crystals and their optical properties, while at the same time presenting the large variety of devices, ranging from optics to microwaves, where photonic crystals have found application. As such, it aims at building bridges between...

  16. Photonic Integrated Circuits

    Science.gov (United States)

    Krainak, Michael; Merritt, Scott

    2016-01-01

    Integrated photonics generally is the integration of multiple lithographically defined photonic and electronic components and devices (e.g. lasers, detectors, waveguides passive structures, modulators, electronic control and optical interconnects) on a single platform with nanometer-scale feature sizes. The development of photonic integrated circuits permits size, weight, power and cost reductions for spacecraft microprocessors, optical communication, processor buses, advanced data processing, and integrated optic science instrument optical systems, subsystems and components. This is particularly critical for small spacecraft platforms. We will give an overview of some NASA applications for integrated photonics.

  17. Trimetallic oxide nanocomposites of transition metals titanium and vanadium by sol-gel technique: synthesis, characterization and electronic properties

    Science.gov (United States)

    Kumar, Amit; Mishra, Neeraj Kumar; Sachan, Komal; Ali, Md Asif; Soaham Gupta, Sachchidanand; Singh, Rajeev

    2018-04-01

    Novel titanium and vanadium based trimetallic oxide nanocomposites (TMONCs) have been synthesized using metal salts of titanium-vanadium along with three others metals viz. tin, aluminium and zinc as precursors by the sol-gel method. Aqueous ammonia and hydrazine hydrate were used as the reducing agents. The preparations of nanocomposites were monitored by observing the visual changes during each step of synthesis. The synthesized TMONCs were characterized using UV–vis, SEM, EDX, TEM and DLS. Band gap of the synthesized TMONCs ranges from 3–4.5 eV determined using tauc plot. FTIR study revealed the molecular stretching and bending peaks of corresponding M–O/M–O–M bonds thus confirming their formation. Molecular composition and particle size were determined using EDX and DLS respectively. Molecular shape, size and surface morphology have been examined by SEM and TEM.

  18. Photon-photon collisions

    International Nuclear Information System (INIS)

    Haissinski, J.

    1986-06-01

    The discussions presented in this paper deal with the following points: distinctive features of gamma-gamma collisions; related processes; photon-photon elastic scattering in the continuum and γγ →gg; total cross section; γγ → V 1 V 2 (V=vector meson); radiative width measurements and light meson spectroscopy; exclusive channels at large /t/; jets and inclusive particle distribution in γγ collisions; and, the photon structure function F γ 2

  19. Photon-photon collisions

    International Nuclear Information System (INIS)

    Burke, D.L.

    1982-10-01

    Studies of photon-photon collisions are reviewed with particular emphasis on new results reported to this conference. These include results on light meson spectroscopy and deep inelastic e#betta# scattering. Considerable work has now been accumulated on resonance production by #betta##betta# collisions. Preliminary high statistics studies of the photon structure function F 2 /sup #betta#/(x,Q 2 ) are given and comments are made on the problems that remain to be solved

  20. Elaboration et caractérisations de nanocristaux organiques fluorescents insérés en coquille sol-gel : vers le développement d'un nouveau type d'agent imageant

    OpenAIRE

    Philippot, Cécile

    2010-01-01

    We demonstrated the feasibility and the reproducibility of our method of one-step elaboration of organic nanocrystals in sol-gel shell obtained by atomization, by using various sort of organic molecules, solvent and sol-gel matrices. The use of different techniques of characterization (scanning electronic microscopy, one and two photons luminescence spectroscopy) allowed to optimized the conditions of elaboration to obtain hybrid nanoparticles of small sizes, with a maximum of fluorophore, hi...

  1. Hybrid photon detectors

    CERN Document Server

    D'Ambrosio, C

    2003-01-01

    Hybrid photon detectors detect light via vacuum photocathodes and accelerate the emitted photoelectrons by an electric field towards inversely polarized silicon anodes, where they are absorbed, thus producing electron-hole pairs. These, in turn, are collected and generate electronic signals on their ohmic contacts. This review first describes the characteristic properties of the main components of hybrid photon detectors: light entrance windows, photocathodes, and silicon anodes. Then, essential relations describing the trajectories of photoelectrons in electric and magnetic fields and their backscattering from the silicon anodes are derived. Depending on their anode configurations, three families of hybrid photon detectors are presented: hybrid photomultiplier tubes with single anodes for photon counting with high sensitivity and for gamma spectroscopy; multi-anode photon detector tubes with anodes subdivided into square or hexagonal pads for position-sensitive photon detection; imaging silicon pixel array t...

  2. Photon-photon collisions

    Energy Technology Data Exchange (ETDEWEB)

    Brodsky, S.J.

    1988-07-01

    Highlights of the VIIIth International Workshop on Photon-Photon Collisions are reviewed. New experimental and theoretical results were reported in virtually every area of ..gamma gamma.. physics, particularly in exotic resonance production and tests of quantum chromodynamics where asymptotic freedom and factorization theorems provide predictions for both inclusive and exclusive ..gamma gamma.. reactions at high momentum transfer. 73 refs., 12 figs.

  3. Dosimetry of an accident in mixed field (neutrons, photons) using the spectrometry by electronic paramagnetic resonance(EPR); Dosimetrie d'accident en champ mixte (neutrons, photons) utilisant la spectrometrie par resonance paramagnetique electronique (RPE)

    Energy Technology Data Exchange (ETDEWEB)

    Herve, M.L

    2006-03-15

    In a radiological accident, the assessment of the dose received by the victim is relevant information for the therapeutic strategy. Two complementary dosimetric techniques based on physical means are used in routine practice in the laboratory: EPR spectroscopy performed on materials removed from the victim or gathered from the vicinity of the victim and Monte Carlo calculations. EPR dosimetry, has been used successfully several times in cases of photon or electron overexposures. Accidental exposure may also occur with a neutron component. The aim of this work is to investigate the potentiality of EPR dosimetry for mixed photon and neutron field exposure with different organic materials (ascorbic acid, sorbitol, glucose, galactose, fructose, mannose, lactose and sucrose). The influence of irradiation parameters (dose, dose rate, photon energy) and of environmental parameters (temperature of heating, light exposure) on the EPR signal amplitude was studied. To assess the neutron sensitivity, the materials were exposed to a mixed radiation field of experimental reactors with different neutron to photon ratios. The relative neutron sensitivity was found to range from 10% to 43% according to the materials. Prior knowledge of the ratio between the dose in samples measured by EPR spectrometry and organ or whole body dose obtained by calculations previously performed for these different configurations, makes it possible to give a first estimation of the dose received by the victim in a short delay. The second aim of this work is to provide data relevant for a quick assessment of the dose distribution in case of accidental overexposure based on EPR measurements performed on one or several points of the body. The study consists in determining by calculation the relation between the dose to the organs and whole body and the dose to specific points of the body, like teeth, bones or samples located in the pockets of victim clothes, for different external exposures corresponding

  4. Effects of Electronic Quantum Interference, Photonic-Crystal Cavity, Longitudinal Field and Surface-Plasmon- Polariton for Optical Amplification

    National Research Council Canada - National Science Library

    Cardimona, David A; Alsing, Paul M; Huang, Danhong

    2008-01-01

    ... by a coupling laser field in a three-level system, field enhancement through the cavity confinement of a radiation field in a photonic crystal and field concentration seen in a transmitted near field...

  5. Fast broad-band photon detector based on quantum well devices and charge-integrating electronics for non-invasive FEL monitoring

    International Nuclear Information System (INIS)

    Antonelli, M.; Cautero, G.; Sergo, R.; Castellaro, C.; Menk, R. H.; Ganbold, T.; Biasiol, G.

    2016-01-01

    The recent evolution of free-electron lasers has not been matched by the development of adequate beam-monitoring instrumentation. However, for both experimental and diagnostics purposes, it is crucial to keep such photon beams under control, avoiding at the same time the absorption of the beam and the possible destruction of the detector. These requirements can be fulfilled by utilizing fast and non-invasive photon detectors operated in situ, upstream from the experimental station. From this perspective, sensors based on Quantum Well (QW) devices can be the key to detecting ultra-short light pulses. In fact, owing to their high electron mobility, InGaAs/InAlAs QW devices operated at room temperature exhibit sub-nanosecond response times. Their direct, low-energy band gap renders them capable of detecting photons ranging from visible to X-ray. Furthermore, the 2D electron gas forming inside the QW is responsible for a charge amplification mechanism, which increases the charge collection efficiency of these devices. In order to acquire the signals produced by these QW sensors, a novel readout electronics has been developed. It is based on a high-speed charge integrator, which allows short, low-intensity current pulses to be read within a 50-ns window. The integrated signal is acquired through an ADC and the entire process can be performed at a 10-MHz repetition rate. This work provides a detailed description of the development of the QW detectors and the acquisition electronics, as well as reporting the main experimental results, which show how these tools are well suited for the realization of fast, broad-band beam monitors.

  6. Photon detectors

    International Nuclear Information System (INIS)

    Va'vra, J.

    1995-10-01

    J. Seguinot and T. Ypsilantis have recently described the theory and history of Ring Imaging Cherenkov (RICH) detectors. In this paper, I will expand on these excellent review papers, by covering the various photon detector designs in greater detail, and by including discussion of mistakes made, and detector problems encountered, along the way. Photon detectors are among the most difficult devices used in physics experiments, because they must achieve high efficiency for photon transport and for the detection of single photo-electrons. For gaseous devices, this requires the correct choice of gas gain in order to prevent breakdown and wire aging, together with the use of low noise electronics having the maximum possible amplification. In addition, the detector must be constructed of materials which resist corrosion due to photosensitive materials such as, the detector enclosure must be tightly sealed in order to prevent oxygen leaks, etc. The most critical step is the selection of the photocathode material. Typically, a choice must be made between a solid (CsI) or gaseous photocathode (TMAE, TEA). A conservative approach favors a gaseous photocathode, since it is continuously being replaced by flushing, and permits the photon detectors to be easily serviced (the air sensitive photocathode can be removed at any time). In addition, it can be argued that we now know how to handle TMAE, which, as is generally accepted, is the best photocathode material available as far as quantum efficiency is concerned. However, it is a very fragile molecule, and therefore its use may result in relatively fast wire aging. A possible alternative is TEA, which, in the early days, was rejected because it requires expensive CaF 2 windows, which could be contaminated easily in the region of 8.3 eV and thus lose their UV transmission

  7. Studies of electroweak interactions and searches for new physics using photonic events with missing energy at the Large Electron-Positron Collider

    CERN Document Server

    Gataullin, Marat I

    2006-01-01

    In this thesis I study the production of photonic events with missing energy in e+e- collisions at the Large Electron-Positron (LEP) Collider. My analysis was based on 619 inverse picobarns of data collected by the L3 detector during 1998--2000 at center-of-mass energies between 189 and 208 GeV, the highest energies ever attained in an e+e- collider. I selected a high-purity sample of 2,022 well-reconstructed single- and multi-photon events with missing energy. I used this sample to study the pair-production of neutrinos accompanied by the emission of one or more photons. The average ratio of the measured to expected cross section was found to be R = 0.987±0.022(stat)±0.014 (syst). The number of light neutrino species was measured to be 2.98±0.05(stat)±0.04(syst), and the first direct evidence for the pair-production of electron neutrinos was found. The experimental errors in these results are smaller than those of comparable previous measurements. The selection results are also given in the form of table...

  8. Applications of anomalous diffraction systems, generation of attosecond electron and photon pulses and Raman amplification by stimulated emission of radiation

    Science.gov (United States)

    Vartak, Sameer Dinkar

    1998-10-01

    efficient delivery of this power to the screen. We describe a method based on optical rectification to create an electron acceleration process which can act simultaneously on a femtosecond photo-electron pulse as well as cancel space-charge effects. This method can be used to produce attosecond electron and photon pulses. Narrow linewidth high intensity tunable light pulses are very useful for applications such as spectroscopic studies and remote sensing. Tunable lasers and stimulated Raman scattering (SRS) process are commonly used for this purpose. SRS process has high threshold because of small spontaneous Raman scattering cross-sections. We combined amplified spontaneous emission (ASE) from dye molecules with SRS process in solvent molecules in which dye molecules are dissolved. ASE seeds SRS process and SRS peak is further amplified by stimulated emission gain. We got amplifications ~100 over SRS from pure solvent. This peak can be tuned over gain bandwidth of dye molecules.

  9. Spiraling contaminant electrons increase doses to surfaces outside the photon beam of an MRI-linac with a perpendicular magnetic field.

    Science.gov (United States)

    Hackett, Sara L; van Asselen, Bram; Wolthaus, Jochem W H; Bluemink, J J; Ishakoglu, Kübra; Kok, Jan G M; Lagendijk, Jan J W; Raaymakers, Bas W

    2018-03-29

    The transverse magnetic field of an MRI-linac sweeps contaminant electrons away from the radiation beam. Films oriented perpendicular to the magnetic field and 5cm from the radiation beam edge show a projection of the divergent beam, indicating that contaminant electrons spiral along magnetic field lines and deposit dose on surfaces outside the primary beam perpendicular to the magnetic field. These spiraling contaminant electrons (SCE) could increase skin doses to protruding regions of the patient along the cranio-caudal axis. This study investigated doses from SCE for an MRI-linac comprising a 7MV linac and a 1.5T MRI scanner. Surface doses to films perpendicular to the magnetic field and 5cm from the radiation beam edge showed increased dose within the projection of the primary beam, whereas films parallel to the magnetic field and 5cm from the beam edge showed no region of increased dose. However, the dose from contaminant electrons is absorbed within a few millimeters. For large fields, the SCE dose is within the same order of magnitude as doses from scattered and leakage photons. Doses for both SCE and scattered photons decrease rapidly with decreasing beam size and increasing distance from the beam edge. © 2018 Institute of Physics and Engineering in Medicine.

  10. Impact of electronic coupling, symmetry, and planarization on one- and two-photon properties of triarylamines with one, two, or three diarylboryl acceptors.

    Science.gov (United States)

    Makarov, Nikolay S; Mukhopadhyay, Sukrit; Yesudas, Kada; Brédas, Jean-Luc; Perry, Joseph W; Pron, Agnieszka; Kivala, Milan; Müllen, Klaus

    2012-04-19

    We have performed a study of the one- and two-photon absorption properties of a systematically varied series of triarylamino-compounds with one, two, or three attached diarylborane arms arranged in linear dipolar, bent dipolar, and octupolar geometries. Two-photon fluorescence excitation spectra were measured over a wide spectral range with femtosecond laser pulses. We found that on going from the single-arm to the two- and three-arm systems, the peak in two-photon absorption (2PA) cross-section is suppressed by factors of 3-11 for the lowest excitonic level associated with the electronic coupling of the arms, whereas it is enhanced by factors of 4-8 for the higher excitonic level. These results show that the coupling of arms redistributes the 2PA cross-section between the excitonic levels in a manner that strongly favors the higher-energy excitonic level. The experimental data on one- and two-photon cross-sections, ground- and excited-state transition dipole moments, and permanent dipole moment differences between the ground and the lowest excited states were compared to the results obtained from a simple Frenkel exciton model and from highly correlated quantum-chemical calculations. It has been found that planarization of the structure around the triarylamine moiety leads to a sizable increase in peak 2PA cross-section for the lowest excitonic level of the two-arm system, whereas for the three-arm system, the corresponding peak was weakened and shifted to lower energy. Our studies show the importance of the interarm coupling, number of arms, and structural planarity on both the enhancement and the suppression of two-photon cross-sections in multiarm molecules. © 2012 American Chemical Society

  11. Characterization of Water-Clear Polymeric Gels for Use as Radiotherapy Bolus.

    Science.gov (United States)

    Adamson, Justus D; Cooney, Tabitha; Demehri, Farokh; Stalnecker, Andrew; Georgas, Debra; Yin, Fang-Fang; Kirkpatrick, John

    2017-01-01

    Our purpose was to investigate polymeric gels for use as a highly transparent radiotherapy bolus and determine the relevant physical and dosimetric properties. We first quantified tensile properties (maximum stress, strain, and Young modulus) for various polymeric gels, along with a commercial bolus product in order to illustrate the wide variety of potential materials. For a select polymeric gel with tensile properties similar to currently used radiotherapy bolus, we also evaluated mass and electron density, effective atomic number, optical transparency, and percent depth dose in clinical megavoltage photon and electron beams. For this polymeric gel, mass density was 872 ± 12 and 896 ± 13 g/cm 3 when measured via weight/volume and computed tomography Hounsfield units, respectively. Electron density was 2.95 ± 0.04 ×10 23 electrons/cm 3 . Adding fused silica (9% by weight) increases density to that of water. The ratio of the effective atomic number to that of water without and with added silica was 0.780 and 0.835 at 1 MeV, 0.767 and 0.826 at 6 MeV, and 0.746 and 0.809 at 20 MeV. Percent depth dose for 6 MV photons was within 2% of water within the first 2.5 cm and after scaling by the density coincided within 1% out to >7 cm. For 6 and 20 MeV electrons, after scaling for density D 80% was within 1.3 and 1.5 mm of water, respectively. The high transparency and mechanical flexibility of polymeric gels indicate potential for use as a radiotherapy bolus; differences in density from water may be managed via either using "water equivalent thickness" or by incorporating fused silica into the material.

  12. Facile Sol-Gel Derived Crater-like Dual-functioning TiO2 Electron Transport Layer for High Efficiency Perovskite Solar Cells.

    Science.gov (United States)

    Ma, Sunihl; Ahn, Jihoon; Oh, Yunjung; Kwon, Hyeok-Chan; Lee, Eunsong; Kim, Kyungmi; Yun, Seong-Cheol; Moon, Jooho

    2018-04-05

    Organic-inorganic hybrid perovskite solar cells (PSCs) are considered promising materials for low-cost solar energy harvesting technology. An electron transport layer (ETL), which facilitates the extraction of photo-generated electrons and their transport to the electrodes, is a key component in planar perovskite solar cells. In this study, a new strategy to concurrently manipulate the electrical and optical properties of ETLs to improve the performance of PSCs is demonstrated. A careful control over the Ti alkoxide-based sol-gel chemistry leads to a crater-like porous/blocking bilayer TiO2 ETL with relatively uniform surface pores of 220 nm diameter. Additionally, the phase separation promoter added to the precursor solution enables nitrogen doping in the TiO2 lattice, thus generating oxygen vacancies. The crater-like surface morphology allows for better light transmission due to reduced reflection, while the electrically conductive crater-like bilayer ETL enhances charge extraction and transport. Through these synergetic improvements in both optical and electrical properties, the power conversion efficiency of crater-like bilayer TiO2 ETL-based PSCs could be increased from 13.7% to 16.0% as compared to conventional dense TiO2-based PSCs.

  13. Electron-positron pair production by gamma-rays in an anisotropic flux of soft photons, and application to pulsar polar caps

    Science.gov (United States)

    Voisin, Guillaume; Mottez, Fabrice; Bonazzola, Silvano

    2018-02-01

    Electron-positron pair production by collision of photons is investigated in view of application to pulsar physics. We compute the absorption rate of individual gamma-ray photons by an arbitrary anisotropic distribution of softer photons, and the energy and angular spectrum of the outgoing leptons. We work analytically within the approximation that 1 ≫ mc2/E > ɛ/E, with E and ɛ the gamma-ray and soft-photon maximum energy and mc2 the electron mass energy. We give results at leading order in these small parameters. For practical purposes, we provide expressions in the form of Laurent series which give correct reaction rates in the isotropic case within an average error of ˜ 7 per cent. We apply this formalism to gamma-rays flying downward or upward from a hot neutron star thermally radiating at a uniform temperature of 106 K. Other temperatures can be easily deduced using the relevant scaling laws. We find differences in absorption between these two extreme directions of almost two orders of magnitude, much larger than our error estimate. The magnetosphere appears completely opaque to downward gamma-rays while there are up to ˜ 10 per cent chances of absorbing an upward gamma-ray. We provide energy and angular spectra for both upward and downward gamma-rays. Energy spectra show a typical double peak, with larger separation at larger gamma-ray energies. Angular spectra are very narrow, with an opening angle ranging from 10-3 to 10-7 radians with increasing gamma-ray energies.

  14. Cleaning ability of chlorhexidine gel and sodium hypochlorite associated or not with EDTA as root canal irrigants: a scanning electron microscopy study

    Directory of Open Access Journals (Sweden)

    Bruno Carvalho de Vasconcelos

    2007-10-01

    Full Text Available The aim of this study was to evaluate the cleaning efficacy of 2% chlorhexidine gluconate gel (CHX compared to 2.5% sodium hypochlorite solution (NaOCl associated or not with 17% EDTA used as irrigants during the biomechanical preparation. Fifty freshly extracted single-rooted human teeth with complete apex formation were randomly divided into five groups: G1 - sterile saline, G2 - 2.5% NaOCl, G3 - 2% CHX, G4 - 2.5% NaOCl + EDTA and G5 - 2% CHX + EDTA. The specimens of G1 were subdivided into two control groups. The teeth were decoronated and the coronal and middle root thirds were prepared with Gates-Glidden burs, and the apical third was reserved to manual instrumentation. All procedures were performed by a single operator. In all groups, 2 mL of irrigant was delivered between each file change. The teeth were sectioned and prepared for analyses under scanning electron microscopy (SEM. SEM micrographs were graded according to a score scale by two examiners. Data were analyzed statistically by Kruskal-Wallis and Dunn tests at 1% significance level. The best results were obtained in the groups in which the irrigant was used followed by the chelating agent. No statistically significant difference was observed among G4, G5 and the positive control group (p<0.01. The groups G2 and G3 were significantly different from the others, presenting the worst cleaning capacity. In conclusion, the use of the chelating agent is necessary to obtain clean canal walls, with open tubules and no heavy debris. The use of 2% chlorhexidine gluconate gel alone is not able to remove the smear layer.

  15. Photon virtual bound state

    International Nuclear Information System (INIS)

    Inoue, J.; Ohtaka, K.

    2004-01-01

    We study virtual bound states in photonics, which are a vectorial extension of electron virtual bound states. The condition for these states is derived. It is found that the Mie resonant state which satisfies the condition that the size parameter is less than the angular momentum should be interpreted as a photon virtual bound state. In order to confirm the validity of the concept, we compare the photonic density of states, the width of which represents the lifetime of the photon virtual bound states, with numerical results

  16. Dosimetric analysis for photon and electron beams in Whole body irradiation; Analisis dosimetrico para haces de fotones y electrones en irradiacion corporal total

    Energy Technology Data Exchange (ETDEWEB)

    Hurtado G, M. [Posgrado. Fisica Medica Radiologica. Universidad Nacional de Colombia, Bogota. Instituto Nacional de Cancerologia. Instituto Regional de Cancer de la Orinoquia. Hospital Regional de Villavicencio, Meta (Colombia)

    1998-12-31

    To initiate the Whole body irradiation as an alternative for the treatment of the hematological diseases, leukemia and assistant for the osseous marrow transplantation, it may be taken account the application of International Protocols about control and quality assurance. It is established the intercomparison by the different dosimetric methods: cylindrical ionization chambers and parallel plane, radiographic emulsion film, semiconductor diodes (Mosfet transistors) and TLD-100 thermoluminescent crystals, obtained measurements for 140 x 140 cm{sup 2} fields and large distances 340 cm respect conventional fields in Radiotherapy. The in vitro dosimetry was realized at the Universal Anthropomorphic puppet Alderson Rando basically with the cylindrical crystals (1 mm diameter) of TLD-100 lithium fluoride. It was obtained the dose value with a 0.6 cm{sup 3} cylindrical ionization chamber and the Farmer electrometer for Whole body irradiation (ICT) with photons for electrons and were obtained values with the Markus plane parallel camera. Knowing the dose rate value to the source-surface distance DFS= 80 cm, it was calibrated the crystals with the reference radiation beam of {sup 60} Co for obtaining the response curve: Dose vs. Tl lecture. It was characterized the 10 % of the total population for 300 crystals for applying the statistics corresponding. The luminescence curve obtained of Gaussian form was considered satisfactory by its stability during the pre-anneal lecture and anneal process, getting the main peak lecture at 300 Centigrade according to assigned parameters at lecture equipment TLD Harshaw model 4500. The results indicate the functional dependence with the distance DFS= 340 cm for the following depth PPD, the relations TMR and TPR, the TAR is not calculated by the increment of the dispersion in air. The penumbra increment indicates an increase of the radiation field respect of luminous field. The dispersion angle q{sub 1} respect at the field central axis

  17. Photonic fabrics take shape

    Science.gov (United States)

    Graham-Rowe, Duncan

    2007-01-01

    Electronics firms, fashion houses and medical-equipment suppliers are all busy developing textiles that blend photonics technology with materials science. Duncan Graham-Rowe reports on the striking results of their endeavours.

  18. CMOS-compatible photonic devices for single-photon generation

    Directory of Open Access Journals (Sweden)

    Xiong Chunle

    2016-09-01

    Full Text Available Sources of single photons are one of the key building blocks for quantum photonic technologies such as quantum secure communication and powerful quantum computing. To bring the proof-of-principle demonstration of these technologies from the laboratory to the real world, complementary metal–oxide–semiconductor (CMOS-compatible photonic chips are highly desirable for photon generation, manipulation, processing and even detection because of their compactness, scalability, robustness, and the potential for integration with electronics. In this paper, we review the development of photonic devices made from materials (e.g., silicon and processes that are compatible with CMOS fabrication facilities for the generation of single photons.

  19. Phenomenological extraction of two-photon exchange amplitudes from elastic electron-proton scattering cross section data

    Science.gov (United States)

    Qattan, I. A.

    2017-05-01

    Background: The inconsistency in the results obtained from the Rosenbluth separation method and the high-Q2 recoil polarization results on the ratio μpGEp/GMp implies a systematic difference between the two techniques. Several studies suggest that missing higher-order radiative corrections to elastic electron-proton scattering cross section σR(ɛ ,Q2) and in particular hard two-photon-exchange (TPE) contributions could account for the discrepancy. Purpose: In this work, I improve on and extend to low and high Q2 values the extractions of the ɛ dependence of the real parts of the TPE amplitudes relative to the magnetic form factor, as well as the ratio Pl/PlBorn(ɛ ,Q2) by using world data on σR(ɛ ,Q2) with an emphasis on precise new data covering the low-momentum region which is sensitive to the large-scale structure of the nucleon. Method: I combine cross section and polarization measurements of elastic electron-proton scattering to extract the TPE amplitudes. Because the recoil polarization data were confirmed "experimentally" to be essentially independent of ɛ , I constrain the ratio Pt/Pl(ɛ ,Q2) to its ɛ -independent term (Born value) by setting the TPE contributions to zero. This allows for the amplitude YM(ɛ ,Q2) and σR(ɛ ,Q2) to be expressed in terms of the remaining two amplitudes YE(ɛ ,Q2) and Y3(ɛ ,Q2) which in turn are parametrized as second-order polynomials in ɛ and Q2 to reserve as possible the linearity of σR(ɛ ,Q2) as well as to account for possible nonlinearities in the TPE amplitudes. Furthermore, I impose the Regge limit which ensures the vanishing of the TPE contributions to σR(ɛ ,Q2) and the TPE amplitudes in the limit ɛ →1 . Results: I provide simple parametrizations of the TPE amplitudes, along with an estimate of the fit uncertainties. The extracted TPE amplitudes are compared with previous phenomenological extractions and TPE calculations. The Pl/PlBorn ratio is extracted by using the new parametrizations of the TPE

  20. High energy photon-photon collisions

    International Nuclear Information System (INIS)

    Brodsky, S.J.; Zerwas, P.M.

    1994-07-01

    The collisions of high energy photons produced at a electron-positron collider provide a comprehensive laboratory for testing QCD, electroweak interactions and extensions of the standard model. The luminosity and energy of the colliding photons produced by back-scattering laser beams is expected to be comparable to that of the primary e + e - collisions. In this overview, we shall focus on tests of electroweak theory in photon-photon annihilation, particularly γγ → W + W - , γγ → Higgs bosons, and higher-order loop processes, such as γγ → γγ, Zγ and ZZ. Since each photon can be resolved into a W + W minus pair, high energy photon-photon collisions can also provide a remarkably background-free laboratory for studying WW collisions and annihilation. We also review high energy γγ tests of quantum chromodynamics, such as the scaling of the photon structure function, t bar t production, mini-jet processes, and diffractive reactions

  1. Respective efficiencies of nuclear collisions and electronic excitations for precipitating Ag clusters in sol-gel films

    CERN Document Server

    Pivin, J C

    2002-01-01

    The growth of silver clusters in co-sputtered SiO sub 2 :Ag films under irradiation with increasing fluences of 1.5 MeV He or 3 MeV Au ions is investigated by recording spectra of optical extinction. The analysis of surface plasmon resonances in these very small clusters on basis of Mie theory permits to estimate more precisely their mean size than TEM images. A linear increase of the mean cluster size with the energy deposited by ions in electronic excitations and little effect of collision cascades are observed. The growth kinetics is ascribed to a process of desorption/re-adsorption of Ag atoms at the surface of clusters.

  2. Photophysical processes in electronic states of zinc tetraphenyl porphyrin accessed on one- and two-photon excitation in the soret region

    International Nuclear Information System (INIS)

    Lukaszewicz, Adam; Karolczak, Jerzy; Kowalska, Dorota; Maciejewski, Andrzej; Ziolek, Marcin; Steer, Ronald P.

    2007-01-01

    Photophysical processes in the model metalloporphyrin, 5,10,15,20-tetraphenyl-21H,23H-porphine zinc (ZnTPP), have been investigated by means of conventional electronic spectroscopy, and by picosecond transient emission and femtosecond transient absorption methods. The radiative and radiationless decay parameters of ZnTPP have been determined under conditions of low solute concentration where dimer formation is unimportant, and the effects of dimer formation at higher concentrations have been assessed. Careful measurements of the relative S 1 -S 0 fluorescence quantum yields produced on excitation to higher states compared with direct excitation to S 1 itself reveal that a second radiationless decay process that bypasses S 1 operates when ZnTPP is excited in the Soret region. A dark state, assigned most probably to a triplet (T n , n > 2) or an upper singlet of gerade parity, is involved. The relative importance of this second process is a function of the nature of the solvent, the excitation wavelength (vibrational energy content of the excited state) and the parity of higher electronic states accessed when two-photon excitation is employed. Sequential two-photon excitation occurs when exciting with fs pulses in the Soret region and becomes significant at even modest excitation pulse energies with increasing sample absorbance. The implications of these measurements in reinterpreting the dynamics of electronically excited ZnTPP are discussed

  3. Nonlinear silicon photonics

    Science.gov (United States)

    Borghi, M.; Castellan, C.; Signorini, S.; Trenti, A.; Pavesi, L.

    2017-09-01

    Silicon photonics is a technology based on fabricating integrated optical circuits by using the same paradigms as the dominant electronics industry. After twenty years of fervid development, silicon photonics is entering the market with low cost, high performance and mass-manufacturable optical devices. Until now, most silicon photonic devices have been based on linear optical effects, despite the many phenomenologies associated with nonlinear optics in both bulk materials and integrated waveguides. Silicon and silicon-based materials have strong optical nonlinearities which are enhanced in integrated devices by the small cross-section of the high-index contrast silicon waveguides or photonic crystals. Here the photons are made to strongly interact with the medium where they propagate. This is the central argument of nonlinear silicon photonics. It is the aim of this review to describe the state-of-the-art in the field. Starting from the basic nonlinearities in a silicon waveguide or in optical resonator geometries, many phenomena and applications are described—including frequency generation, frequency conversion, frequency-comb generation, supercontinuum generation, soliton formation, temporal imaging and time lensing, Raman lasing, and comb spectroscopy. Emerging quantum photonics applications, such as entangled photon sources, heralded single-photon sources and integrated quantum photonic circuits are also addressed at the end of this review.

  4. Non-markovian model of photon-assisted dephasing by electron-phonon interactions in a coupled quantum-dot-cavity system

    DEFF Research Database (Denmark)

    Nielsen, Per Kær; Nielsen, Torben Roland; Lodahl, Peter

    2010-01-01

    treatments. A pronounced consequence is the emergence of a phonon induced spectral asymmetry when detuning the cavity from the quantum-dot resonance. The asymmetry can only be explained when considering the polaritonic quasiparticle nature of the quantum-dot-cavity system. Furthermore, a temperature induced......We investigate the influence of electron-phonon interactions on the dynamical properties of a quantum-dot-cavity QED system. We show that non-Markovian effects in the phonon reservoir lead to strong changes in the dynamics, arising from photon-assisted dephasing processes, not present in Markovian...

  5. Procedure for the determination of uranium on cellulose air-sampling filters by photon-electron-rejecting-alpha-liquid-scintillation spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    McDowell, W.J.; Case, G.N.

    1986-08-01

    A procedure is described for obtaining from cellulose air-sampling filters the total uranium content whether it be in the form of metal, oxide, tetrafluoride or most other salts of uranium. It is demonstrated that the uranium content can be accurately assayed by low-temperature ashing of the filter paper, dissolving the ash in a mixed nitrate-sulfate system, extracting the uranium selectively into a scintillator containing a high-molecular-weight amine sulfate, and counting the extract using a Photon-Electron-Rejecting-Alpha-Liquid-Scintillation (PERALS) spectrometer. 2 refs., 4 figs., 2 tabs.

  6. Photonics: Technology project summary

    Science.gov (United States)

    Depaula, Ramon P.

    1991-01-01

    Photonics involves the use of light (photons) in conjunction with electronics for applications in communications, computing, control, and sensing. Components used in photonic systems include lasers, optical detectors, optical wave guide devices, fiber optics, and traditional electronic devices. The goal of this program is to develop hybrid optoelectronic devices and systems for sensing, information processing, communications, and control. It is hoped that these new devices will yield at least an order of magnitude improvement in performance over existing technology. The objective of the program is to conduct research and development in the following areas: (1) materials and devices; (2) networking and computing; (3) optical processing/advanced pattern recognition; and (4) sensing.

  7. Photon-photon collisions

    Energy Technology Data Exchange (ETDEWEB)

    Brodsky, S.J.

    1985-01-01

    The study of photon-photon collisions has progressed enormously, stimulated by new data and new calculational tools for QCD. In the future we can expect precise determinations of ..cap alpha../sub s/ and ..lambda../sup ms/ from the ..gamma..*..gamma.. ..-->.. ..pi../sup 0/ form factor and the photon structure function, as well as detailed checks of QCD, determination of the shape of the hadron distribution amplitudes from ..gamma gamma.. ..-->.. H anti H, reconstruction of sigma/sub ..gamma gamma../ from exclusive channels at low W/sub ..gamma gamma../, definitive studies of high p/sub T/ hadron and jet production, and studies of threshold production of charmed systems. Photon-photon collisions, along with radiative decays of the psi and UPSILON, are ideal for the study of multiquark and gluonic resonances. We have emphasized the potential for resonance formation near threshold in virtually every hadronic exclusive channel, including heavy quark states c anti c c anti c, c anti c u anti u, etc. At higher energies SLC, LEP, ...) parity-violating electroweak effects and Higgs production due to equivalent Z/sup 0/ and W/sup + -/ beams from e ..-->.. eZ/sup 0/ and e ..-->.. nu W will become important. 44 references.

  8. Photon-photon collisions

    International Nuclear Information System (INIS)

    Brodsky, S.J.

    1985-01-01

    The study of photon-photon collisions has progressed enormously, stimulated by new data and new calculational tools for QCD. In the future we can expect precise determinations of α/sub s/ and Λ/sup ms/ from the γ*γ → π 0 form factor and the photon structure function, as well as detailed checks of QCD, determination of the shape of the hadron distribution amplitudes from γγ → H anti H, reconstruction of sigma/sub γγ/ from exclusive channels at low W/sub γγ/, definitive studies of high p/sub T/ hadron and jet production, and studies of threshold production of charmed systems. Photon-photon collisions, along with radiative decays of the psi and UPSILON, are ideal for the study of multiquark and gluonic resonances. We have emphasized the potential for resonance formation near threshold in virtually every hadronic exclusive channel, including heavy quark states c anti c c anti c, c anti c u anti u, etc. At higher energies SLC, LEP, ...) parity-violating electroweak effects and Higgs production due to equivalent Z 0 and W +- beams from e → eZ 0 and e → nu W will become important. 44 references

  9. Biomedical photonics handbook biomedical diagnostics

    CERN Document Server

    Vo-Dinh, Tuan

    2014-01-01

    Shaped by Quantum Theory, Technology, and the Genomics RevolutionThe integration of photonics, electronics, biomaterials, and nanotechnology holds great promise for the future of medicine. This topic has recently experienced an explosive growth due to the noninvasive or minimally invasive nature and the cost-effectiveness of photonic modalities in medical diagnostics and therapy. The second edition of the Biomedical Photonics Handbook presents fundamental developments as well as important applications of biomedical photonics of interest to scientists, engineers, manufacturers, teachers, studen

  10. Sensitivity calibration procedures in optical-CT scanning of BANG 3 polymer gel dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Y.; Wuu, Cheng-Shie; Maryanski, Marek J. [Department of Radiation Oncology, Columbia University, New York, New York 10032 (United States); Department of Radiation Oncology, Columbia University, New York, New York 10032 and MGS Research Inc., Madison, Connecticut 06443 (United States)

    2010-02-15

    The dose response of the BANG 3 polymer gel dosimeter (MGS Research Inc., Madison, CT) was studied using the OCTOPUS laser CT scanner (MGS Research Inc., Madison, CT). Six 17 cm diameter and 12 cm high Barex cylinders, and 18 small glass vials were used to house the gel. The gel phantoms were irradiated with 6 and 10 MV photons, as well as 12 and 16 MeV electrons using a Varian Clinac 2100EX. Three calibration methods were used to obtain the dose response curves: (a) Optical density measurements on the 18 glass vials irradiated with graded doses from 0 to 4 Gy using 6 or 10 MV large field irradiations; (b) optical-CT scanning of Barex cylinders irradiated with graded doses (0.5, 1, 1.5, and 2 Gy) from four adjacent 4x4 cm{sup 2} photon fields or 6x6 cm{sup 2} electron fields; and (c) percent depth dose (PDD) comparison of optical-CT scans with ion chamber measurements for 6x6 cm{sup 2}, 12 and 16 MeV electron fields. The dose response of the BANG 3 gel was found to be linear and energy independent within the uncertainties of the experimental methods (about 3%). The slopes of the linearly fitted dose response curves (dose sensitivities) from the four field irradiations (0.0752{+-}3%, 0.0756{+-}3%, 0.0767{+-}3%, and 0.0759{+-}3% cm{sup -1} Gy{sup -1}) and the PDD matching methods (0.0768{+-}3% and 0.0761{+-}3% cm{sup -1} Gy{sup -1}) agree within 2.2%, indicating a good reproducibility of the gel dose response within phantoms of the same geometry. The dose sensitivities from the glass vial approach are different from those of the cylindrical Barex phantoms by more than 30%, owing probably to the difference in temperature inside the two types of phantoms during gel formation and irradiation, and possible oxygen contamination of the glass vial walls. The dose response curve obtained from the PDD matching approach with 16 MeV electron field was used to calibrate the gel phantom irradiated with the 12 MeV, 6x6 cm{sup 2} electron field. Three-dimensional dose distributions

  11. Description of diffraction-grating experiments for photons and electrons in Feynman's spacetime formulation of quantum mechanics: the quantum origins of classical wave theories of light and massive particles

    Science.gov (United States)

    Field, J. H.

    2013-11-01

    The five laws of relativistic quantum mechanics, according to Feynman's path integral formulation, are concisely stated and applied to experiments. Reflection-diffraction-grating experiments for both photons and electrons are analysed, in particular, the Davisson-Germer experiment in which the wave-like property of electrons was first established. It is shown how classical, purely spatial, effective wave theories for both photons and electrons are predicted by the path integral formulation of quantum mechanics. The standard Copenhagen interpretation of wave mechanics is critically discussed in the light of the described experimental applications of the path integral formulation.

  12. One-photon two-electron processes in helium close to the double ionization threshold; Diexcitation electronique de l'helium par un photon au voisinage du seuil de double ionisation

    Energy Technology Data Exchange (ETDEWEB)

    Bouri, C

    2007-04-15

    This work presents a study of the {sup 1}P{sup 0} excited states of He that can be reached by absorption of a single photon carrying an energy close to the double ionization threshold (DIT) (79 eV). Above the DIT, these states are the double continuum states; below, they are the double excited states. These two types of states are tightly coupled to the single continuum states with or without excitation of the residual ion He{sup +}, owing to their degeneracy in energy. In a one-photon process, these states can only be formed owing to the electronic correlations in the system which must be well described to obtain quantitative good results. Our study is a part of the work which aims at a united description of all these doubly excited, ionized-excited, and double continuum states. We use the Hyperspherical R-Matrix with Semiclassical Outgoing Waves (HRM-SOW) method, initially dedicated to double photoionization studies. We extend it to extract information on the single continuum. This extension allows us to compute cross sections of single photoionization with or without excitation up to n 50 for an excess of 100 meV just above the double ionization threshold. A deep insight into this process is given by a partial waves analysis. The results obtained shed light on the key role of angular and radial correlations. The numerous data we obtain on double and single ionization allow us to establish a continuity relation between these two processes. We show that single ionization with an infinite excitation of the residual ion merges into double photoionization when the excess energy is redistributed between the two electrons. It appears that this relation is valid not only for low but also for high photon energies. Since the HRM-SOW can produce the integrated cross section for double photoionization with high accuracy in the low energy domain, we check the Wannier threshold law. The parameters extracted support strongly this threshold law, and are in good agreement with

  13. On the quantum electrodynamics of mutually interacting charge-fields. A new approach to photon quantization in electron-positron processes

    International Nuclear Information System (INIS)

    Leiter, D.

    1978-01-01

    The ''charge-field'' approach to electrodynamics, in the microcosm, is based on the paradigm that ''charges'' and their associated electromagnetic ''fields'' are permanently connected in ''charge-field'' functional structures, with physical processes being described by the interactions between various ''charge-field'' entities. It has been shown that, at the classical and semi-classical level, this approach is completely finite and self-consistent and requires no ''infinite'' subtraction programs for the evaluation of observable physical quantities. In a hole-theoretic ''second-quantized'' formulation of this theory, presented here, quantizing the ''charges'' (associated with Dirac anticommutation relations for electron-positron operators) automatically quantizes the electromagnetic ''charge-field'' operators. This generates ''photon'' states as a secondary dynamical manifestation of electron-positron quantization. In this paper, a possible approach to the second quantization of ''charge-fields'', in the Heisenberg picture, which might lead to a better formulation of quantum electrodynamics, is discussed. (author)

  14. Calculation of effective atomic numbers and electron densities of different types of material for total photon interaction in the continuous energy region via different methods

    Directory of Open Access Journals (Sweden)

    Mehmet Büyükyıldız

    2017-06-01

    Full Text Available Effective atomic number (Zeff and electron density (Neff are convenient parameters used to characterise the radiation response of a multi-element material in the technical and industrial applications, radiation shielding design, absorbed dose and build-up factor calculations. Thus, it is very significant to choose accurate method to determine these parameters unambiguously. In the present study, effective atomic numbers and electron densities of different types of materials have been calculated by using a direct method and an interpolation method for total photon interaction in the energy region of 1 keV to 100 GeV. In addition, agreements and disagreements of the used methods have been discussed, and from the results, significant variations have been observed between the methods used to compute for the materials in the different energy regions.

  15. Progress in neuromorphic photonics

    Science.gov (United States)

    Ferreira de Lima, Thomas; Shastri, Bhavin J.; Tait, Alexander N.; Nahmias, Mitchell A.; Prucnal, Paul R.

    2017-03-01

    As society's appetite for information continues to grow, so does our need to process this information with increasing speed and versatility. Many believe that the one-size-fits-all solution of digital electronics is becoming a limiting factor in certain areas such as data links, cognitive radio, and ultrafast control. Analog photonic devices have found relatively simple signal processing niches where electronics can no longer provide sufficient speed and reconfigurability. Recently, the landscape for commercially manufacturable photonic chips has been changing rapidly and now promises to achieve economies of scale previously enjoyed solely by microelectronics. By bridging the mathematical prowess of artificial neural networks to the underlying physics of optoelectronic devices, neuromorphic photonics could breach new domains of information processing demanding significant complexity, low cost, and unmatched speed. In this article, we review the progress in neuromorphic photonics, focusing on photonic integrated devices. The challenges and design rules for optoelectronic instantiation of artificial neurons are presented. The proposed photonic architecture revolves around the processing network node composed of two parts: a nonlinear element and a network interface. We then survey excitable lasers in the recent literature as candidates for the nonlinear node and microring-resonator weight banks as the network interface. Finally, we compare metrics between neuromorphic electronics and neuromorphic photonics and discuss potential applications.

  16. A practical theoretical formalism for atomic multielectron processes: direct multiple ionization by a single auger decay or by impact of a single electron or photon

    Science.gov (United States)

    Liu, Pengfei; Zeng, Jiaolong; Yuan, Jianmin

    2018-04-01

    Multiple electron processes occur widely in atoms, molecules, clusters, and condensed matters when they are interacting with energetic particles or intense laser fields. Direct multielectron processes (DMEP) are the most complicated among the general multiple electron processes and are the most difficult to describe theoretically. In this work, a unified and accurate theoretical formalism is proposed on the DMEP of atoms including the multiple auger decay and multiple ionization by an impact of a single electron or a single photon based on the atomic collision theory described by a correlated many-body Green's function. Such a practical treatment is made possible by taking consideration of the different coherence features of the atoms (matter waves) in the initial and final states. We first explain how the coherence characteristics of the ejected continuum electrons is largely destructed, by taking the electron impact direct double ionization process as an example. The direct double ionization process is completely different from the single ionization where the complete interference can be maintained. The detailed expressions are obtained for the energy correlations among the continuum electrons and energy resolved differential and integral cross sections according to the separation of knock-out (KO) and shake-off (SO) mechanisms for the electron impact direct double ionization, direct double and triple auger decay, and double and triple photoionization (TPI) processes. Extension to higher order DMEP than triple ionization is straight forward by adding contributions of the following KO and SO processes. The approach is applied to investigate the electron impact double ionization processes of C+, N+, and O+, the direct double and triple auger decay of the K-shell excited states of C+ 1s2{s}22{p}2{}2D and {}2P, and the double and TPI of lithium. Comparisons with the experimental and other theoretical investigations wherever available in the literature show that our

  17. CERN manufactured hybrid photon detectors

    CERN Multimedia

    Maximilien Brice

    2004-01-01

    These hybrid photon detectors (HPDs) produce an electric signal from a single photon. An electron is liberated from a photocathode and accelerated to a silicon pixel array allowing the location of the photon on the cathode to be recorded. The electronics and optics for these devices have been developed in close collaboration with industry. HPDs have potential for further use in astrophysics and medical imaging.

  18. Polymer gel dosimetry system for radiation therapy

    International Nuclear Information System (INIS)

    Maryanski, M.J.; Schulz, R.J.; Gignac, C.; Eastman, P.; Gore, J.C.

    1995-01-01

    Purpose/Objective: Recently developed treatment modalities such as stereotactic and conformal radiation therapy produce complex dose distributions which are difficult or impractical to measure with conventional dosimetry instrumentation. Three-dimensional treatment planning systems which purport to calculate these complex dose distributions should be compared to experimental results before being routinely applied to clinical problems. There is a need for a new class of tissue-equivalent dosimeters capable of providing accurate, high resolution, time-integrated and three dimensional dose distributions. The recently developed BANG polymer gel dosimetry system (MGS Research, Inc., Guilford, CT) is ideally suited for the task described above. Physico-chemical principles of the polymer gel dosimetry are presented, together with examples of its application to radiation therapy. Data analysis and display program, written for Macintosh computer, is demonstrated. Materials and Methods: Radiation-induced polymerization of acrylic monomers, which are dispersed in tissue-equivalent gelatin, has been shown to be dependent on the dose, but independent of the dose rate or photon energy. Therefore, the spatial distribution of polymer in the gel is precisely representative of the dose distribution. As the polymeric microparticles reduce the water proton NMR relaxation times in the gel, the dose distribution can be measured with high resolution and accuracy using magnetic resonance imaging. Also, as these microparticles cannot diffuse through the gelatin matrix, their distribution is permanent. An improved formulation of the BANG dosimeter consists of 3% w/v acrylic acid, 3% N,N'-methylene-bis-acrylamide, 1% sodium hydroxide, 5% gelatin, and 88% water. MR images are transferred via a local network to a Macintosh computer, and R2 maps constructed on the basis of multiple TE images, using a non-linear least squares fit based on the Levenberg-Marquardt algorithm. A dose-to-R2

  19. Thermoresponsive Gels

    OpenAIRE

    Taylor, M. Joan; Tomlins, P.; Sahota, T. S.

    2016-01-01

    An invited review and relates to the responsive gel used in the "artificial pancreas" work og INsmart, DMU. This article is an Open Access journal. Thermoresponsive gelling materials constructed from natural and synthetic polymers can be used to provide triggered action and therefore customised products such as drug delivery and regenerative medicine types as well as for other industries. Some materials give Arrhenius-type viscosity changes based on coil to globule transitions. Others ...

  20. Photon Production Within Storage Capsules

    CERN Document Server

    Rittmann, P D

    2003-01-01

    This report provides tables and electronic worksheets that list the photon production rate within SrF2 and CsC1 storage capsules, particularly the continuous spectrum of bremsstrahlung photons from the slowing down of the emitted electrons (BREMCALC).

  1. CONFERENCE: Photon-photon collisions

    International Nuclear Information System (INIS)

    Anon.

    1983-01-01

    Despite being difficult to observe, photon-photon collisions have opened up a range of physics difficult, or even impossible, to access by other methods. The progress which has been made in this field was evident at the fifth international workshop on photon-photon