WorldWideScience

Sample records for geant4 physics processes

  1. GPU in Physics Computation: Case Geant4 Navigation

    CERN Document Server

    Seiskari, Otto; Niemi, Tapio

    2012-01-01

    General purpose computing on graphic processing units (GPU) is a potential method of speeding up scientific computation with low cost and high energy efficiency. We experimented with the particle physics simulation toolkit Geant4 used at CERN to benchmark its geometry navigation functionality on a GPU. The goal was to find out whether Geant4 physics simulations could benefit from GPU acceleration and how difficult it is to modify Geant4 code to run in a GPU. We ported selected parts of Geant4 code to C99 & CUDA and implemented a simple gamma physics simulation utilizing this code to measure efficiency. The performance of the program was tested by running it on two different platforms: NVIDIA GeForce 470 GTX GPU and a 12-core AMD CPU system. Our conclusion was that GPUs can be a competitive alternate for multi-core computers but porting existing software in an efficient way is challenging.

  2. Comparison Study on Low Energy Physics Model of GEANT4

    International Nuclear Information System (INIS)

    Park, So Hyun; Jung, Won Gyun; Suh, Tae Suk

    2010-01-01

    The Geant4 simulation toolkit provides improved or renewed physics model according to the version. The latest Geant4.9.3 which has been recoded by developers applies inserted Livermore data and renewed physics model to the low energy electromagnetic physics model. And also, Geant4.9.3 improved the physics factors by modified code. In this study, the stopping power and CSDA(Continuously Slowing Down Approximation) range data of electron or particles were acquired in various material and then, these data were compared with NIST(National Institute of Standards and Technology) data. Through comparison between data of Geant4 simulation and NIST, the improvement of physics model on low energy electromagnetic of Geant4.9.3 was evaluated by comparing the Geant4.9.2

  3. Status of the physics validation studies using Geant4 in ATLAS

    CERN Document Server

    AUTHOR|(CDS)2108477

    2003-01-01

    The new simulation for the ATLAS detector at LHC is performed using Geant4 in a complete OO/C++ environment. In this framework the simulation of the various test beams for the different ATLAS subdetectors offers an excellent opportunity to perform physics validation studies over a wide range of physics domains: the electromagnetic processes, the individual hadronic interactions, the electromagnetic and hadronic signals in calorimeters. The simulation is implemented by paying special attention to all details of the experimental layout and by testing all possible physics processes which may be of relevance to the specific detector under test: the resulting simulation programs are often more detailed than the corresponding Geant3-based simulation suites. In this paper we present relevant features of muon, electron and pion signals in various ATLAS detectors. All remaining discrepancies between Geant4 and test-beam data are currently being addressed and progress is continuous. This work shows that Geant4 is becom...

  4. Software process in Geant4

    International Nuclear Information System (INIS)

    Cosmo, G.

    2001-01-01

    Since its erliest years of R and D, the GEANT4 simulation toolkit has been developed following software process standards which dictated the overall evolution of the project. The complexity of the software involved, the wide areas of application of the software product, the huge amount of code and Category complexity, the size and distributed nature of the Collaboration itself are all ingredients which involve and correlate together a wide variety of software processes. Although in 'production' and available to the public since December 1998, the GEANT4 software product includes Category Domains which are still under active development. Therefore they require different treatment also in terms of improvement of the development cycle, system testing and user support. The author is meant to describe some of the software processes as they are applied in GEANT4 for both development, testing and maintenance of the software

  5. Geant4-MT: bringing multi-threading into Geant4 production

    International Nuclear Information System (INIS)

    Ahn, S.; Apostolakis, J.; Cosmo, G.; Nowak, A.; Asai, M.; Brandt, D.; Dotti, A.; Coopermann, G.; Dong, X.; Jun, Soon Yung

    2013-01-01

    Geant4-MT is the multi-threaded version of the Geant4 particle transport code. The key goals for the design of Geant4-MT have been a) the need to reduce the memory footprint of the multi-threaded application compared to the use of separate jobs and processes; b) to create an easy migration of the existing applications; and c) to use efficiently many threads or cores, by scaling up to tens and potentially hundreds of workers. The first public release of a Geant4- MT prototype was made in 2011. We report on the revision of Geant4-MT for inclusion in the production-level release scheduled for end of 2013. This has involved significant re-engineering of the prototype in order to incorporate it into the main Geant4 development line, and the porting of Geant4-MT threading code to additional platforms. In order to make the porting of applications as simple as possible, refinements addressed the needs of standalone applications. Further adaptations were created to improve the fit with the frameworks of High Energy Physics experiments. We report on performances measurements on Intel Xeon TM , AMD Opteron TM the first trials of Geant4-MT on the Intel Many Integrated Cores (MIC) architecture, in the form of the Xeon Phi TM co-processor. These indicate near-linear scaling through about 200 threads on 60 cores, when holding fixed the number of events per thread. (authors)

  6. Recent progress of Geant4 electromagnetic physics for calorimeter simulation

    Science.gov (United States)

    Incerti, S.; Ivanchenko, V.; Novak, M.

    2018-02-01

    We report on recent progress in the Geant4 electromagnetic (EM) physics sub-packages. New interfaces and models introduced recently in Geant4 10.3 are already used in LHC applications and may be useful for any type of simulation. Additional developments for EM physics are available with the new public version Geant4 10.4 (December, 2017). Important developments for calorimetry applications were carried out for the modeling of single and multiple scattering of charged particles. Corrections to scattering of positrons and to sampling of displacement have recently been added to the Geant4 default Urban model. The fully theory-based Goudsmit-Saunderson (GS) model for electron/positron multiple scattering was recently reviewed and a new improved version is available in Geant4 10.4. For testing purposes for novel calorimeters we provide a configuration of electron scattering based on the GS model or on the single scattering model (SS) instead of the Urban model. In addition, the GS model with Mott corrections enabled is included in the option4 EM physics constructor. This EM configuration provides the most accurate results for scattering of electrons and positrons.

  7. Progress in Geant4 Electromagnetic Physics Modelling and Validation

    International Nuclear Information System (INIS)

    Apostolakis, J; Burkhardt, H; Ivanchenko, V N; Asai, M; Bagulya, A; Grichine, V; Brown, J M C; Chikuma, N; Cortes-Giraldo, M A; Elles, S; Jacquemier, J; Guatelli, S; Incerti, S; Kadri, O; Maire, M; Urban, L; Pandola, L; Sawkey, D; Toshito, T; Yamashita, T

    2015-01-01

    In this work we report on recent improvements in the electromagnetic (EM) physics models of Geant4 and new validations of EM physics. Improvements have been made in models of the photoelectric effect, Compton scattering, gamma conversion to electron and muon pairs, fluctuations of energy loss, multiple scattering, synchrotron radiation, and high energy positron annihilation. The results of these developments are included in the new Geant4 version 10.1 and in patches to previous versions 9.6 and 10.0 that are planned to be used for production for run-2 at LHC. The Geant4 validation suite for EM physics has been extended and new validation results are shown in this work. In particular, the effect of gamma-nuclear interactions on EM shower shape at LHC energies is discussed. (paper)

  8. Research in Geant4 electromagnetic physics design, and its effects on computational performance and quality assurance

    CERN Document Server

    Augelli, M; Hauf, S; Kim, C H; Kuster, M; Pia, M G; Filho, P Queiroz; Quintieri, L; Saracco, P; Santos, D Souza; Weidenspointner, G; Zoglauer, A

    2009-01-01

    The Geant4 toolkit offers a rich variety of electromagnetic physics models; so far the evaluation of this Geant4 domain has been mostly focused on its physics functionality, while the features of its design and their impact on simulation accuracy, computational performance and facilities for verification and validation have not been the object of comparable attention yet, despite the critical role they play in many experimental applications. A new project is in progress to study the application of new design concepts and software techniques in Geant4 electromagnetic physics, and to evaluate how they can improve on the current simulation capabilities. The application of a policy-based class design is investigated as a means to achieve the objective of granular decomposition of processes; this design technique offers various advantages in terms of flexibility of configuration and computational performance. The current Geant4 physics models have been re-implemented according to the new design as a pilot project....

  9. Experiences on Grid Production for GEANT4

    CERN Document Server

    Lamanna, M; Méndez-Lorenzo, P; Moscicki, J; Ribon, A

    2007-01-01

    Geant4 is a worldwide collaboration of scientists and software engineers whose goal is to develop, maintain and provide support for the Geant4 package, representing a general purpose Monte Carlo toolkit for simulating the propagation of particles through matter. Geant4 is currently employed in a row of particle physics experiments (BaBar, HARP, ATLAS, CMS, LHCb), and is also applied in other areas like space science, medical applications, and radiation studies. Due to the complexity of the Geant4 code and to the broad spectrum of possible configurations - involving a variety of physical processes for different source particles, particle energies and target or shielding materials - an intensive testing of new release candidates is mandatory to thoroughly test each of its components, especially before major releases, generally twice a year. Regression tests are required to be performed by the Geant4 team within a short period of time (2 to 3 weeks), basically demanding vast computational resources (equivalent t...

  10. R and D on the Geant4 radioactive decay physics

    Energy Technology Data Exchange (ETDEWEB)

    Hauf, Steffen; Kuster, Markus; Lang, Philipp M.; Hoffmann, Dieter H.H. [IKP, TU Darmstadt (Germany); Pia, Maria Grazia [CERN, Genf (Switzerland); INFN, Genua (Italy); Bell, Zane [Oak Ridge National Lab. (United States); Weidenspointner, Georg [MPI HLL, Muenchen (Germany); MPE, Garching (Germany); Zoglauer, Andreas [SSL, Berkeley (United States)

    2010-07-01

    The anticipated high sensitivity of the next generation X-ray space missions, like the International X-ray Observatory, rely on a low instrumental background, which in turn requires optimized shielding concepts for the instruments. Most state-of-the-art approaches estimate the prompt cosmic ray, solar proton and the cosmic X-ray induced background with simulations using the Geant4 Monte Carlo tool-kit whose electromagnetic and hadronic physics models have extensively been verified with space and ground based experiments. In contrast measurements to verify the radioactive decay implementation in Geant4 have been rare or have only been tested on a limited set of isotopes, which are not necessarily those used in satellite construction. We present first results of two experiments aimed to verify Geant4 activation and decay physics for materials significant for low background X-ray detectors in space.

  11. A Software Toolkit to Study Systematic Uncertainties of the Physics Models of the Geant4 Simulation Package

    Science.gov (United States)

    Genser, Krzysztof; Hatcher, Robert; Kelsey, Michael; Perdue, Gabriel; Wenzel, Hans; Wright, Dennis H.; Yarba, Julia

    2017-10-01

    The Geant4 simulation toolkit is used to model interactions between particles and matter. Geant4 employs a set of validated physics models that span a wide range of interaction energies. These models rely on measured cross-sections and phenomenological models with the physically motivated parameters that are tuned to cover many application domains. To study what uncertainties are associated with the Geant4 physics models we have designed and implemented a comprehensive, modular, user-friendly software toolkit that allows the variation of one or more parameters of one or more Geant4 physics models involved in simulation studies. It also enables analysis of multiple variants of the resulting physics observables of interest in order to estimate the uncertainties associated with the simulation model choices. Based on modern event-processing infrastructure software, the toolkit offers a variety of attractive features, e.g. flexible run-time configurable workflow, comprehensive bookkeeping, easy to expand collection of analytical components. Design, implementation technology, and key functionalities of the toolkit are presented in this paper and illustrated with selected results.

  12. A Toolkit to Study Sensitivity of the Geant4 Predictions to the Variations of the Physics Model Parameters

    Energy Technology Data Exchange (ETDEWEB)

    Fields, Laura [Fermilab; Genser, Krzysztof [Fermilab; Hatcher, Robert [Fermilab; Kelsey, Michael [SLAC; Perdue, Gabriel [Fermilab; Wenzel, Hans [Fermilab; Wright, Dennis H. [SLAC; Yarba, Julia [Fermilab

    2017-08-21

    Geant4 is the leading detector simulation toolkit used in high energy physics to design detectors and to optimize calibration and reconstruction software. It employs a set of carefully validated physics models to simulate interactions of particles with matter across a wide range of interaction energies. These models, especially the hadronic ones, rely largely on directly measured cross-sections and phenomenological predictions with physically motivated parameters estimated by theoretical calculation or measurement. Because these models are tuned to cover a very wide range of possible simulation tasks, they may not always be optimized for a given process or a given material. This raises several critical questions, e.g. how sensitive Geant4 predictions are to the variations of the model parameters, or what uncertainties are associated with a particular tune of a Geant4 physics model, or a group of models, or how to consistently derive guidance for Geant4 model development and improvement from a wide range of available experimental data. We have designed and implemented a comprehensive, modular, user-friendly software toolkit to study and address such questions. It allows one to easily modify parameters of one or several Geant4 physics models involved in the simulation, and to perform collective analysis of multiple variants of the resulting physics observables of interest and comparison against a variety of corresponding experimental data. Based on modern event-processing infrastructure software, the toolkit offers a variety of attractive features, e.g. flexible run-time configurable workflow, comprehensive bookkeeping, easy to expand collection of analytical components. Design, implementation technology, and key functionalities of the toolkit are presented and illustrated with results obtained with Geant4 key hadronic models.

  13. Electro and gamma nuclear physics in Geant4

    CERN Document Server

    Wellisch, J P; Degtyarenko, P V

    2003-01-01

    Adequate description of electro and gamma nuclear physics is of utmost importance in studies of electron beam-dumps and intense electron beam accelerators. I also is mandatory to describe neutron backgrounds and activation in linear colliders. This physics was elaborated in Geant4 over the last year, and now entered into the stage of practical application. In the {\\sc Geant4} Photo-nuclear data base there are at present about 50 nuclei for which the Photo-nuclear absorption cross sections have been measured. Of these, data on 14 nuclei are used to parametrize the gamma nuclear reaction cross-section The resulting cross section is a complex, factorized function of $A$ and $e = log(E_\\gamma)$, where $E_\\gamma$ is the energy of the incident photon. Electro-nuclear reactions are so closely connected with Photo-nuclear reactions that sometimes they are often called ``Photo-nuclear''. The one-photon exchange mechanism dominates in Electro-nuclear reactions, and the electron can be substituted by a flux of photons. ...

  14. Nuclear spectroscopy with Geant4. The superheavy challenge

    Science.gov (United States)

    Sarmiento, Luis G.

    2016-12-01

    The simulation toolkit Geant4 was originally developed at CERN for high-energy physics. Over the years it has been established as a swiss army knife not only in particle physics but it has seen an accelerated expansion towards nuclear physics and more recently to medical imaging and γ- and ion- therapy to mention but a handful of new applications. The validity of Geant4 is vast and large across many particles, ions, materials, and physical processes with typically various different models to choose from. Unfortunately, atomic nuclei with atomic number Z > 100 are not properly supported. This is likely due to the rather novelty of the field, its comparably small user base, and scarce evaluated experimental data. To circumvent this situation different workarounds have been used over the years. In this work the simulation toolkit Geant4 will be introduced with its different components and the effort to bring the software to the heavy and superheavy region will be described.

  15. Parallel Geometries in Geant4 foundation and recent enhancements

    CERN Document Server

    Apostolakis, J; Cosmo, G; Howard, A; Ivanchenko, V; Verderi, M

    2009-01-01

    The Geant4 software toolkit simulates the passage of particles through matter. It is utilized in high energy and nuclear physics experiments, in medical physics and space applications. For many applications it is necessary to measure particle fluxes and radiation doses in parts of the setup where there are complex structures. To undertake this in a flexible way, Geant4 has tools to create and use additional, parallel, geometrical hierarchies within a single application. A separate, parallel geometry can be used for each one amongst shower parameterization, event biasing, scoring of radiation, and/or the creation of hits in detailed readout structures. We describe the existing basic capabilities of the Geant4 toolkit to create multiple geometries and the recent major enhancements undertaken to streamline, enhance and extend these. New functionality enables Geant4 developers to offer new embedded schemes for scoring (requiring no user C++ code); has simplified the implementation of processes or capabilities usi...

  16. Low-energy electron dose-point kernel simulations using new physics models implemented in Geant4-DNA

    Energy Technology Data Exchange (ETDEWEB)

    Bordes, Julien, E-mail: julien.bordes@inserm.fr [CRCT, UMR 1037 INSERM, Université Paul Sabatier, F-31037 Toulouse (France); UMR 1037, CRCT, Université Toulouse III-Paul Sabatier, F-31037 (France); Incerti, Sébastien, E-mail: incerti@cenbg.in2p3.fr [Université de Bordeaux, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); Lampe, Nathanael, E-mail: nathanael.lampe@gmail.com [Université de Bordeaux, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); Bardiès, Manuel, E-mail: manuel.bardies@inserm.fr [CRCT, UMR 1037 INSERM, Université Paul Sabatier, F-31037 Toulouse (France); UMR 1037, CRCT, Université Toulouse III-Paul Sabatier, F-31037 (France); Bordage, Marie-Claude, E-mail: marie-claude.bordage@inserm.fr [CRCT, UMR 1037 INSERM, Université Paul Sabatier, F-31037 Toulouse (France); UMR 1037, CRCT, Université Toulouse III-Paul Sabatier, F-31037 (France)

    2017-05-01

    When low-energy electrons, such as Auger electrons, interact with liquid water, they induce highly localized ionizing energy depositions over ranges comparable to cell diameters. Monte Carlo track structure (MCTS) codes are suitable tools for performing dosimetry at this level. One of the main MCTS codes, Geant4-DNA, is equipped with only two sets of cross section models for low-energy electron interactions in liquid water (“option 2” and its improved version, “option 4”). To provide Geant4-DNA users with new alternative physics models, a set of cross sections, extracted from CPA100 MCTS code, have been added to Geant4-DNA. This new version is hereafter referred to as “Geant4-DNA-CPA100”. In this study, “Geant4-DNA-CPA100” was used to calculate low-energy electron dose-point kernels (DPKs) between 1 keV and 200 keV. Such kernels represent the radial energy deposited by an isotropic point source, a parameter that is useful for dosimetry calculations in nuclear medicine. In order to assess the influence of different physics models on DPK calculations, DPKs were calculated using the existing Geant4-DNA models (“option 2” and “option 4”), newly integrated CPA100 models, and the PENELOPE Monte Carlo code used in step-by-step mode for monoenergetic electrons. Additionally, a comparison was performed of two sets of DPKs that were simulated with “Geant4-DNA-CPA100” – the first set using Geant4′s default settings, and the second using CPA100′s original code default settings. A maximum difference of 9.4% was found between the Geant4-DNA-CPA100 and PENELOPE DPKs. Between the two Geant4-DNA existing models, slight differences, between 1 keV and 10 keV were observed. It was highlighted that the DPKs simulated with the two Geant4-DNA’s existing models were always broader than those generated with “Geant4-DNA-CPA100”. The discrepancies observed between the DPKs generated using Geant4-DNA’s existing models and “Geant4-DNA-CPA100” were

  17. A Software Toolkit to Study Systematic Uncertainties of the Physics Models of the Geant4 Simulation Package

    CERN Document Server

    Genser, Krzysztof; Perdue, Gabriel; Wenzel, Hans; Yarba, Julia; Kelsey, Michael; Wright, Dennis H

    2016-01-01

    The Geant4 toolkit is used to model interactions between particles and matter. Geant4 employs a set of validated physics models that span a wide range of interaction energies. These models are tuned to cover a large variety of possible applications. This raises the critical question of what uncertainties are associated with the Geant4 physics model, or group of models, involved in a simulation project. To address the challenge, we have designed and implemented a comprehen- sive, modular, user-friendly software toolkit that allows the variation of one or more parameters of one or more Geant4 physics models involved in simulation studies. It also enables analysis of multiple variants of the resulting physics observables of interest in order to estimate the uncertain- ties associated with the simulation model choices. Key functionalities of the toolkit are presented in this paper and are illustrated with selected results.

  18. Physical models implemented in the Geant4-DNA extension of the Geant-4 toolkit for calculating initial radiation damage at the molecular level

    International Nuclear Information System (INIS)

    Villagrasa, C.; Francis, Z.; Incerti, S.

    2011-01-01

    The ROSIRIS project aims to study the radiobiology of integrated systems for medical treatment optimisation using ionising radiations and evaluate the associated risk. In the framework of this project, one research focus is the interpretation of the initial radio-induced damage in DNA created by ionising radiation (and detected by γH2AX foci analysis) from the track structure of the incident particles. In order to calculate the track structure of ionising particles at a nano-metric level, the Geant4 Monte Carlo toolkit was used. Geant4 (Object Oriented Programming Architecture in C++) offers a common platform, available free to all users and relatively easy to use. Nevertheless, the current low-energy threshold for electromagnetic processes in GEANT4 is set to 1 keV (250 eV using the Livermore processes), which is an unsuitable value for nano-metric applications. To lower this energy threshold, the necessary interaction processes and models were identified, and the corresponding available cross sections collected from the literature. They are mostly based on the plane-wave Born approximation (first Born approximation, or FBA) for inelastic interactions and on semi-empirical models for energies where the FBA fails (at low energies). In this paper, the extensions that have been introduced into the 9.3 release of the Geant4 toolkit are described, the so-called Geant4-DNA extension, including a set of processes and models adapted in this study and permitting the simulation of electron (8 eV -1 MeV), proton (100 eV-100 MeV) and alpha particle (1 keV-10 MeV) interactions in liquid water. (authors)

  19. Design and performance evaluations of generic programming techniques in a R and D prototype of Geant4 physics

    Energy Technology Data Exchange (ETDEWEB)

    Pia, M G; Saracco, P; Sudhakar, M [INFN Sezione di Genova, Via Dodecaneso 33, 16146 Genova (Italy); Zoglauer, A [University of California at Berkeley, Berkeley, CA 94720-7450 (United States); Augelli, M [CNES, 18 Av. Edouard Belin, 31401 Toulouse (France); Gargioni, E [University Medical Center Hamburg-Eppendorf, D-20246 Hamburg (Germany); Kim, C H [Hanyang University, 17 Haengdang-dong, Seongdong-gu, Seoul, 133-791 (Korea, Republic of); Quintieri, L [INFN Laboratori Nazionali di Frascati, Via Enrico Fermi 40, I-00044 Frascati (Italy); Filho, P P de Queiroz; Santos, D de Souza [IRD, Av. Salvador Allende, s/n. 22780-160, Rio de Janeiro, RJ (Brazil); Weidenspointner, G [MPI fuer extraterrestrische Physik Postfach 1603, D-85740 Garching (Germany); Begalli, M, E-mail: mariagrazia.pia@ge.infn.i [UERJ, R. Sao Francisco Xavier, 524. 20550-013, Rio de Janeiro, RJ (Brazil)

    2010-04-01

    A R and D project has been recently launched to investigate Geant4 architectural design in view of addressing new experimental issues in HEP and other related physics disciplines. In the context of this project the use of generic programming techniques besides the conventional object oriented is investigated. Software design features and preliminary results from a new prototype implementation of Geant4 electromagnetic physics are illustrated. Performance evaluations are presented. Issues related to quality assurance in Geant4 physics modelling are discussed.

  20. GEANT 4: an Object-Oriented toolkit for simulation in HEP

    CERN Multimedia

    Kent, P; Sirotenko, V; Komogorov, M; Pavliouk, A; Greeniaus, G L; Kayal, P I; Routenburg, P; Tanaka, S; Duellmann, D; Innocente, V; Paoli, S; Ranjard, F; Riccardi, F; Ruggier, M; Shiers, J; Egli, S; Kimura, A; Urban, P; Prior, S; Walkden, A; Forti, A; Magni, S; Strahl, K; Kokoulin, R; Braune, K; Volcker, C; Ullrich, T; Takahata, M; Nieminen, P; Ballocchi, G; Mora De Freitas, P; Verderi, M; Rybine, A; Langeveld, W; Nagamatsu, M; Hamatsu, R; Katayama, N; Chuma, J; Felawka, L; Gumplinger, P; Axen, D

    2002-01-01

    %RD44 %title\\\\ \\\\The GEANT4 software has been developed by a world-wide collaboration of about 100 scientists from over 40 institutions and laboratories participating in more than 10 experiments in Europe, Russia, Japan, Canada, and the United States. The GEANT4 detector simulation toolkit has been designed for the next generation of High Energy Physics (HEP) experiments, with primary requirements from the LHC, the CP violation, and the heavy ions experiments. In addition, GEANT4 also meets the requirements from the space and medical communities, thanks to very low energy extensions developed in a joint project with the European Space Agency (ESA). GEANT4 has exploited advanced software engineering techniques (for example PSS-05) and Object-Oriented technology to improve the validation process of the physics results, and in the same time to make possible the distributed software design and development in the world-wide collaboration. Fifteen specialised working groups have been responsible for fields as diver...

  1. Beam Tools for Geant4 (User's Guide)

    International Nuclear Information System (INIS)

    V.Daniel Elvira, Paul Lebrun and Panagiotis Spentzouris email daniel@fnal.gov

    2002-01-01

    Geant4 is a tool kit developed by a collaboration of physicists and computer professionals in the high energy physics field for simulation of the passage of particles through matter. The motivation for the development of the Beam Tools is to extend the Geant4 applications to accelerator physics. The Beam Tools are a set of C++ classes designed to facilitate the simulation of accelerator elements: r.f. cavities, magnets, absorbers, etc. These elements are constructed from Geant4 solid volumes like boxes, tubes, trapezoids, or spheers. There are many computer programs for beam physics simulations, but Geant4 is ideal to model a beam through a material or to integrate a beam line with a complex detector. There are many such examples in the current international High Energy Physics programs. For instance, an essential part of the RandD associated with the Neutrino Source/Muon Collider accelerator is the ionization cooling channel, which is a section of the system aimed to reduce the size of the muon beam in phase space. The ionization cooling technique uses a combination of linacs and light absorbers to reduce the transverse momentum and size of the beam, while keeping the longitudinal momentum constant. The MuCool/MICE (muon cooling) experiments need accurate simulations of the beam transport through the cooling channel in addition to a detailed simulation of the detectors designed to measure the size of the beam. The accuracy of the models for physics processes associated with muon ionization and multiple scattering is critical in this type of applications. Another example is the simulation of the interaction region in future accelerators. The high luminosity and background environments expected in the Next Linear Collider (NLC) and the Very Large Hadron Collider (VLHC) pose great demand on the detectors, which may be optimized by means of a simulation of the detector-accelerator interface

  2. Geant4 2005 10. user conference and collaboration workshop. Slides

    International Nuclear Information System (INIS)

    Maire, M.; Amako, K.; Agapov, I.; Allison, J.; Amako, K.; Anah, J.; Apostolakis, J.; Asai, M.; Aso, T.; Barrand, G.; Becheva, E.; Berthoumieux, E.; Bongrand, M.; Boudard, A.; Canchel, G.; Capra, R.; Carlier, Th.; Chambon, P.; Chipaux, R.; Cognet, M.A.; Cornelius, I.; Cosmo, G.; Beenhouwer, J. de; Derreumaux, S.; Desbree, A.; Descourt, P.; Dridi, W.; Ersmark, T.; Faddegon, B.; Ferrer, L.; Flacco, A.; Folger, G.; Francis, S.; Giovinazzo, J.; Glinec, Y.; Godart, J.; Goncalves, P.; Gottschlag, H.; Grichine, V.; Guatelli, S.; Gudowska, I.; Guemnie Tafo, A.; Gueye, P.; Gumplinger, P.; Gurriaran, R.; Hannachi, F.; Heikkinen, A.; Hill, D.; Honore, P.F.; Howard, A.; Hrivnacova, I.; Hubert, X.; Incerti, S.; Ivanchenko, V.; Jacquemier, J.; Jones, F.; Kerhoas-Cavata, S.; Klem, J.; Koi, T.; Kosov, M.; Labalme, M.; Lang, N.; Lemercier, M.; Lemiere, Y.; Leroy, P.; Link, O.; Liu, B.; Lydon, J.; Maire, M.; Marchand, D.; Marquet, Ch.; Mascialino, B.; Matea, I.; Mccormick, J.; Mclaren, I.; Merchant, M.; Miceli, A.; Mine, Ph.; Moretto, Ph.; Mount, R.; Murakami, K.; Nachab, H.; Nehmeh, S.; Nieminen, P.; Paganetti, H.; Pallon, J.; Pandola, L.; Perl, J.; Perrot, F.; Pia Maria, G.; Piqueras, I.; Pouthier, Th.; Pshenichnov, I.; Raaijmakers, A.; Raaymakers, B.; Reuillon, R.; Ribon, A.; Rodrigues, P.; Rogel, G.; Salehzahi, F.; Santin, G.; Sasaki, T.; Schubert, M.; Seznec, H.; Shipley, D.; Skaza, F.; Thiam Cheick, O.; Tome, B.; Traneus, E.; Trindade, A.; Truscott, P.; Vacanti, G.; Verderi, M.; Watase, Y.; Wright, D.; Yarba, J.; Yoshida, H.; Zacharatou-Jarlskog, Ch.; Zhang, Q.

    2005-01-01

    Originally developed for the simulation of large scale particle physics experiments, the field of applications of the conferences Geant4 is growing fast worldwide especially at the physics medicine biology frontier. In this framework the 2005 Geant4 conference was dedicated to simulations with a strong interest at the physics medicine biology frontier. In particular the following topics were discussed: review of simulation applications for medicine, validation of Geant4 models for medical physics, simulation of radiotherapy and irradiation setups, treatment planning in radiotherapy, dosimetry, parallelization, imaging techniques, data handling, related GRID developments and applications and the Geant4 DNA project with related Monte Carlo tools. Slides are provided. (A.L.B.)

  3. Geant4 2005 10. user conference and collaboration workshop. Slides

    Energy Technology Data Exchange (ETDEWEB)

    Maire, M; Amako, K; Agapov, I; Allison, J; Amako, K; Anah, J; Apostolakis, J; Asai, M; Aso, T; Barrand, G; Becheva, E; Berthoumieux, E; Bongrand, M; Boudard, A; Canchel, G; Capra, R; Carlier, Th; Chambon, P; Chipaux, R; Cognet, M A; Cornelius, I; Cosmo, G; Beenhouwer, J de; Derreumaux, S; Desbree, A; Descourt, P; Dridi, W; Ersmark, T; Faddegon, B; Ferrer, L; Flacco, A; Folger, G; Francis, S; Giovinazzo, J; Glinec, Y; Godart, J; Goncalves, P; Gottschlag, H; Grichine, V; Guatelli, S; Gudowska, I; Guemnie Tafo, A; Gueye, P; Gumplinger, P; Gurriaran, R; Hannachi, F; Heikkinen, A; Hill, D; Honore, P F; Howard, A; Hrivnacova, I; Hubert, X; Incerti, S; Ivanchenko, V; Jacquemier, J; Jones, F; Kerhoas-Cavata, S; Klem, J; Koi, T; Kosov, M; Labalme, M; Lang, N; Lemercier, M; Lemiere, Y; Leroy, P; Link, O; Liu, B; Lydon, J; Maire, M; Marchand, D; Marquet, Ch; Mascialino, B; Matea, I; Mccormick, J; Mclaren, I; Merchant, M; Miceli, A; Mine, Ph; Moretto, Ph; Mount, R; Murakami, K; Nachab, H; Nehmeh, S; Nieminen, P; Paganetti, H; Pallon, J; Pandola, L; Perl, J; Perrot, F; Pia Maria, G; Piqueras, I; Pouthier, Th; Pshenichnov, I; Raaijmakers, A; Raaymakers, B; Reuillon, R; Ribon, A; Rodrigues, P; Rogel, G; Salehzahi, F; Santin, G; Sasaki, T; Schubert, M; Seznec, H; Shipley, D; Skaza, F; Thiam Cheick, O; Tome, B; Traneus, E; Trindade, A; Truscott, P; Vacanti, G; Verderi, M; Watase, Y; Wright, D; Yarba, J; Yoshida, H; Zacharatou-Jarlskog, Ch; Zhang, Q

    2005-07-01

    Originally developed for the simulation of large scale particle physics experiments, the field of applications of the conferences Geant4 is growing fast worldwide especially at the physics medicine biology frontier. In this framework the 2005 Geant4 conference was dedicated to simulations with a strong interest at the physics medicine biology frontier. In particular the following topics were discussed: review of simulation applications for medicine, validation of Geant4 models for medical physics, simulation of radiotherapy and irradiation setups, treatment planning in radiotherapy, dosimetry, parallelization, imaging techniques, data handling, related GRID developments and applications and the Geant4 DNA project with related Monte Carlo tools. Slides are provided. (A.L.B.)

  4. G4-STORK: A Geant4-based Monte Carlo reactor kinetics simulation code

    International Nuclear Information System (INIS)

    Russell, Liam; Buijs, Adriaan; Jonkmans, Guy

    2014-01-01

    Highlights: • G4-STORK is a new, time-dependent, Monte Carlo code for reactor physics applications. • G4-STORK was built by adapting and expanding on the Geant4 Monte Carlo toolkit. • G4-STORK was designed to simulate short-term fluctuations in reactor cores. • G4-STORK is well suited for simulating sub- and supercritical assemblies. • G4-STORK was verified through comparisons with DRAGON and MCNP. - Abstract: In this paper we introduce G4-STORK (Geant4 STOchastic Reactor Kinetics), a new, time-dependent, Monte Carlo particle tracking code for reactor physics applications. G4-STORK was built by adapting and expanding on the Geant4 Monte Carlo toolkit. The toolkit provides the fundamental physics models and particle tracking algorithms that track each particle in space and time. It is a framework for further development (e.g. for projects such as G4-STORK). G4-STORK derives reactor physics parameters (e.g. k eff ) from the continuous evolution of a population of neutrons in space and time in the given simulation geometry. In this paper we detail the major additions to the Geant4 toolkit that were necessary to create G4-STORK. These include a renormalization process that maintains a manageable number of neutrons in the simulation even in very sub- or supercritical systems, scoring processes (e.g. recording fission locations, total neutrons produced and lost, etc.) that allow G4-STORK to calculate the reactor physics parameters, and dynamic simulation geometries that can change over the course of simulation to illicit reactor kinetics responses (e.g. fuel temperature reactivity feedback). The additions are verified through simple simulations and code-to-code comparisons with established reactor physics codes such as DRAGON and MCNP. Additionally, G4-STORK was developed to run a single simulation in parallel over many processors using MPI (Message Passing Interface) pipes

  5. The Geant4 Bertini Cascade

    Energy Technology Data Exchange (ETDEWEB)

    Wright, D.H.; Kelsey, M.H.

    2015-12-21

    One of the medium energy hadron–nucleus interaction models in the GEANT4 simulation toolkit is based partly on the Bertini intranuclear cascade model. Since its initial appearance in the toolkit, this model has been largely re-written in order to extend its physics capabilities and to reduce its memory footprint. Physics improvements include extensions in applicable energy range and incident particle types, and improved hadron–nucleon cross-sections and angular distributions. Interfaces have also been developed which allow the model to be coupled with other GEANT4 models at lower and higher energies. The inevitable speed reductions due to enhanced physics have been mitigated by memory and CPU efficiency improvements. Details of these improvements, along with selected comparisons of the model to data, are discussed.

  6. Quantitative Test of the Evolution of Geant4 Electron Backscattering Simulation

    CERN Document Server

    Basaglia, Tullio; Hoff, Gabriela; Kim, Chan Hyeong; Kim, Sung Hun; Pia, Maria Grazia; Saracco, Paolo

    2016-01-01

    Evolutions of Geant4 code have affected the simulation of electron backscattering with respect to previously published results. Their effects are quantified by analyzing the compatibility of the simulated electron backscattering fraction with a large collection of experimental data for a wide set of physics configuration options available in Geant4. Special emphasis is placed on two electron scattering implementations first released in Geant4 version 10.2: the Goudsmit-Saunderson multiple scattering model and a single Coulomb scattering model based on Mott cross section calculation. The new Goudsmit-Saunderson multiple scattering model appears to perform equally or less accurately than the model implemented in previous Geant4 versions, depending on the electron energy. The new Coulomb scattering model was flawed from a physics point of view, but computationally fast in Geant4 version 10.2; the physics correction released in Geant4 version 10.2p01 severely degrades its computational performance. Evolutions in ...

  7. Geant4 application in a Web browser

    International Nuclear Information System (INIS)

    Garnier, Laurent

    2014-01-01

    Geant4 is a toolkit for the simulation of the passage of particles through matter. The Geant4 visualization system supports many drivers including OpenGL[1], OpenInventor, HepRep[2], DAWN[3], VRML, RayTracer, gMocren[4] and ASCIITree, with diverse and complementary functionalities. Web applications have an increasing role in our work, and thanks to emerging frameworks such as Wt [5], building a web application on top of a C++ application without rewriting all the code can be done. Because the Geant4 toolkit's visualization and user interface modules are well decoupled from the rest of Geant4, it is straightforward to adapt these modules to render in a web application instead of a computer's native window manager. The API of the Wt framework closely matches that of Qt [6], our experience in building Qt driver will benefit for Wt driver. Porting a Geant4 application to a web application is easy, and with minimal effort, Geant4 users can replicate this process to share their own Geant4 applications in a web browser.

  8. Comparison of GEANT4 very low energy cross section models with experimental data in water

    DEFF Research Database (Denmark)

    Incerti, S; Ivanchenko, A; Karamitros, M

    2010-01-01

    The GEANT4 general-purpose Monte Carlo simulation toolkit is able to simulate physical interaction processes of electrons, hydrogen and helium atoms with charge states (H0, H+) and (He0, He+, He2+), respectively, in liquid water, the main component of biological systems, down to the electron volt...... of electromagnetic interactions within the GEANT4 toolkit framework (since GEANT4 version 9.3 beta). This work presents a quantitative comparison of these physics models with a collection of experimental data in water collected from the literature....

  9. Validation Test of Geant4 Simulation of Electron Backscattering

    CERN Document Server

    Kim, Sung Hun; Basaglia, Tullio; Han, Min Cheol; Hoff, Gabriela; Kim, Chan Hyeong; Saracco, Paolo

    2015-01-01

    Backscattering is a sensitive probe of the accuracy of electron scattering algorithms implemented in Monte Carlo codes. The capability of the Geant4 toolkit to describe realistically the fraction of electrons backscattered from a target volume is extensively and quantitatively evaluated in comparison with experimental data retrieved from the literature. The validation test covers the energy range between approximately 100 eV and 20 MeV, and concerns a wide set of target elements. Multiple and single electron scattering models implemented in Geant4, as well as preassembled selections of physics models distributed within Geant4, are analyzed with statistical methods. The evaluations concern Geant4 versions from 9.1 to 10.1. Significant evolutions are observed over the range of Geant4 versions, not always in the direction of better compatibility with experiment. Goodness-of-fit tests complemented by categorical analysis tests identify a configuration based on Geant4 Urban multiple scattering model in Geant4 vers...

  10. Geant4 electromagnetic physics for high statistic simulation of LHC experiments

    CERN Document Server

    Allison, J; Bagulya, A; Champion, C; Elles, S; Garay, F; Grichine, V; Howard, A; Incerti, S; Ivanchenko, V; Jacquemier, J; Maire, M; Mantero, A; Nieminen, P; Pandola, L; Santin, G; Sawkey, D; Schalicke, A; Urban, L

    2012-01-01

    An overview of the current status of electromagnetic physics (EM) of the Geant4 toolkit is presented. Recent improvements are focused on the performance of large scale production for LHC and on the precision of simulation results over a wide energy range. Significant efforts have been made to improve the accuracy without compromising of CPU speed for EM particle transport. New biasing options have been introduced, which are applicable to any EM process. These include algorithms to enhance and suppress processes, force interactions or splitting of secondary particles. It is shown that the performance of the EM sub-package is improved. We will report extensions of the testing suite allowing high statistics validation of EM physics. It includes validation of multiple scattering, bremsstrahlung and other models. Cross checks between standard and low-energy EM models have been performed using evaluated data libraries and reference benchmark results.

  11. The GEANT4 Visualization System

    International Nuclear Information System (INIS)

    Allison, J

    2007-01-01

    The Geant4 Visualization System is a multi-driver graphics system designed to serve the Geant4 Simulation Toolkit. It is aimed at the visualization of Geant4 data, primarily detector descriptions and simulated particle trajectories and hits. It can handle a variety of graphical technologies simultaneously and interchangeably, allowing the user to choose the visual representation most appropriate to requirements. It conforms to the low-level Geant4 abstract graphical user interfaces and introduces new abstract classes from which the various drivers are derived and that can be straightforwardly extended, for example, by the addition of a new driver. It makes use of an extendable class library of models and filters for data representation and selection. The Geant4 Visualization System supports a rich set of interactive commands based on the Geant4 command system. It is included in the Geant4 code distribution and maintained and documented like other components of Geant4

  12. Recent progress of GEANT4 electromagnetic physics for LHC and other applications

    NARCIS (Netherlands)

    Bagulya, A.; Brown, J.M.C.; Burkhardt, H.; Grichine, V.; Guatelli, S.; Incerti, S.; Ivanchenko, V. N.; Kadri, O.; Karamitros, M.; Maire, M.; Mashtakov, K.; Novak, M; Pandola, L.; Rancoita, P. G.; Sawkey, D.; Tacconi, M.; Urban, L.

    2017-01-01

    We report on the recent progress within the Geant4 electromagnetic physics subpackages. Several new interfaces and models recently introduced are already used in LHC applications and may be useful for any type of simulation. Significant developments were carried out to improve the user interface,

  13. Geant4-DNA: overview and recent developments

    Science.gov (United States)

    Štěpán, Václav

    Space travel and high altitude flights are inherently associated with prolonged exposure to cosmic and solar radiation. Understanding and simulation of radiation action on cellular and subcellular level contributes to precise assessment of the associated health risks and remains a challenge of today’s radiobiology research. The Geant4-DNA project (http://geant4-dna.org) aims at developing an experimentally validated simulation platform for modelling of the damage induced by ionizing radiation at DNA level. The platform is based on the Geant4 Monte Carlo simulation toolkit. This project extends specific functionalities of Geant4 in following areas: The step-by-step single scattering modelling of elementary physical interactions of electrons, protons, alpha particles and light ions with liquid water and DNA bases, for the so-called “physical” stage. The modelling of the “physico-chemical and chemical” stages corresponding to the production, the diffusion, the chemical reactions occurring between chemical species produced by water radiolysis, and to the radical attack on the biological targets. Physical and chemical stage simulations are combined with biological target models on several scales, from DNA double helix, through nucleosome, to chromatin segments and cell geometries. In addition, data mining clustering algorithms have been developed and optimised for the purpose of DNA damage scoring in simulated tracks. Experimental measurements on pBR322 plasmid DNA are being carried out in order to validate the Geant4-DNA models. The plasmid DNA has been irradiated in dry conditions by protons with energies from 100 keV to 30 MeV and in aqueous conditions, with and without scavengers, by 30 MeV protons, 290 MeV/u carbon and 500 MeV/u iron ions. Agarose gel electrophoresis combined with enzymatic treatment has been used to measure the resulting DNA damage. An overview of the developments undertaken by the Geant4-DNA collaboration including a description of

  14. Beam simulation tools for GEANT4 (and neutrino source applications)

    International Nuclear Information System (INIS)

    V.Daniel Elvira, Paul Lebrun and Panagiotis Spentzouris email daniel@fnal.gov

    2002-01-01

    Geant4 is a tool kit developed by a collaboration of physicists and computer professionals in the High Energy Physics field for simulation of the passage of particles through matter. The motivation for the development of the Beam Tools is to extend the Geant4 applications to accelerator physics. Although there are many computer programs for beam physics simulations, Geant4 is ideal to model a beam going through material or a system with a beam line integrated to a complex detector. There are many examples in the current international High Energy Physics programs, such as studies related to a future Neutrino Factory, a Linear Collider, and a very Large Hadron Collider

  15. Recent developments in GEANT4

    Energy Technology Data Exchange (ETDEWEB)

    Allison, J. [Geant4 Associates International Ltd., 9 Royd Terrace, Hebden Bridge HX7 7BT (United Kingdom); The University of Manchester, School of Physics and Astronomy, Manchester M13 9PL (United Kingdom); Amako, K. [KEK, 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Geant4 Associates International Ltd., 9 Royd Terrace, Hebden Bridge HX7 7BT (United Kingdom); Apostolakis, J. [CERN, 1211 Genéve 23 (Switzerland); Arce, P. [CIEMAT, Medical Applications Unit, Avenida Complutense 40, 28040 Madrid (Spain); Asai, M. [SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States); Aso, T. [National Institute of Technology, Toyama College, 1-2 Ebie Neriya, Imizu, Toyama 9330293 (Japan); Bagli, E. [INFN Sezione di Ferrara, Via Saragat 1, 44122 Ferrara (Italy); Bagulya, A. [Lebedev Physical Institute, Leninskii Pr. 53, Moscow 119991 (Russian Federation); Banerjee, S. [Fermi National Accelerator Laboratory, P.O. Box 500, Batavia, IL 60510 (United States); Barrand, G. [IN2P3/LAL, Universite Paris-Sud, Orsay (France); Beck, B.R. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, CA 94550 (United States); Bogdanov, A.G. [National Research Nuclear University (Moscow Engineering Physics Institute), Kashirskoe shosse 31, Moscow 115409 (Russian Federation); Brandt, D. [SSW Trading, Am Knick 4, Oststeinbek (Germany); Brown, J.M.C. [Queen' s University Belfast, School of Mathematics and Physics, University Road, Belfast, Northern Ireland BT7 1NN (United Kingdom); Burkhardt, H. [CERN, 1211 Genéve 23 (Switzerland); Canal, Ph. [Fermi National Accelerator Laboratory, P.O. Box 500, Batavia, IL 60510 (United States); Cano-Ott, D. [CIEMAT, Centro de Investigaciones Energéticas Medioambientales y Tecnólogicas, Avenida Complutense 40, 28040 Madrid (Spain); Chauvie, S. [Sante Croce e Carle Hospital, Via Coppino 26, I-12100 Cuneo (Italy); and others

    2016-11-01

    GEANT4 is a software toolkit for the simulation of the passage of particles through matter. It is used by a large number of experiments and projects in a variety of application domains, including high energy physics, astrophysics and space science, medical physics and radiation protection. Over the past several years, major changes have been made to the toolkit in order to accommodate the needs of these user communities, and to efficiently exploit the growth of computing power made available by advances in technology. The adaptation of GEANT4 to multithreading, advances in physics, detector modeling and visualization, extensions to the toolkit, including biasing and reverse Monte Carlo, and tools for physics and release validation are discussed here. - Highlights: • Multithreading resulted in a smaller memory footprint and nearly linear speed-up. • Scoring options, faster geometry primitives, more versatile visualization were added. • Improved electromagnetic and hadronic models and cross sections were developed. • Reverse Monte Carlo and general biasing methods were added. • Physics validation efforts were expanded and new validation tools were added.

  16. Geant4 - A Simulation Toolkit

    International Nuclear Information System (INIS)

    2002-01-01

    Geant4 is a toolkit for simulating the passage of particles through matter. It includes a complete range of functionality including tracking, geometry, physics models and hits. The physics processes offered cover a comprehensive range, including electromagnetic, hadronic and optical processes, a large set of long-lived particles, materials and elements, over a wide energy range starting, in some cases, from 250 eV and extending in others to the TeV energy range. it has been designed and constructed to expose the physics models utilized, to handle complex geometries, and to enable its easy adaptation for optimal use in different sets of applications. The toolkit is the result of a worldwide collaboration of physicists and software engineers. It has been created exploiting software engineering and object-oriented technology and implemented in the C++ programming language. It has been used in applications in particle physics, nuclear physics, accelerator design, space engineering and medical physics

  17. GEANT4 A Simulation toolkit

    CERN Document Server

    Agostinelli, S; Amako, K; Apostolakis, John; Araújo, H M; Arce, P; Asai, M; Axen, D A; Banerjee, S; Barrand, G; Behner, F; Bellagamba, L; Boudreau, J; Broglia, L; Brunengo, A; Chauvie, S; Chuma, J; Chytracek, R; Cooperman, G; Cosmo, G; Degtyarenko, P V; Dell'Acqua, A; De Paola, G O; Dietrich, D D; Enami, R; Feliciello, A; Ferguson, C; Fesefeldt, H S; Folger, G; Foppiano, F; Forti, A C; Garelli, S; Giani, S; Giannitrapani, R; Gibin, D; Gómez-Cadenas, J J; González, I; Gracía-Abríl, G; Greeniaus, L G; Greiner, W; Grichine, V M; Grossheim, A; Gumplinger, P; Hamatsu, R; Hashimoto, K; Hasui, H; Heikkinen, A M; Howard, A; Hutton, A M; Ivanchenko, V N; Johnson, A; Jones, F W; Kallenbach, Jeff; Kanaya, N; Kawabata, M; Kawabata, Y; Kawaguti, M; Kelner, S; Kent, P; Kodama, T; Kokoulin, R P; Kossov, M; Kurashige, H; Lamanna, E; Lampen, T; Lara, V; Lefébure, V; Lei, F; Liendl, M; Lockman, W; Longo, F; Magni, S; Maire, M; Mecking, B A; Medernach, E; Minamimoto, K; Mora de Freitas, P; Morita, Y; Murakami, K; Nagamatu, M; Nartallo, R; Nieminen, P; Nishimura, T; Ohtsubo, K; Okamura, M; O'Neale, S W; O'Ohata, Y; Perl, J; Pfeiffer, A; Pia, M G; Ranjard, F; Rybin, A; Sadilov, S; Di Salvo, E; Santin, G; Sasaki, T; Savvas, N; Sawada, Y; Scherer, S; Sei, S; Sirotenko, V I; Smith, D; Starkov, N; Stöcker, H; Sulkimo, J; Takahata, M; Tanaka, S; Chernyaev, E; Safai-Tehrani, F; Tropeano, M; Truscott, P R; Uno, H; Urbàn, L; Urban, P; Verderi, M; Walkden, A; Wander, W; Weber, H; Wellisch, J P; Wenaus, T; Williams, D C; Wright, D; Yamada, T; Yoshida, H; Zschiesche, D

    2003-01-01

    Geant4 is a toolkit for simulating the passage of particles through matter. It includes a complete range of functionality including tracking, geometry, physics models and hits. The physics processes offered cover a comprehensive range, including electromagnetic, hadronic and optical processes, a large set of long-lived particles, materials and elements, over a wide energy range starting, in some cases, from 250 eV and extending in others to the TeV energy range. It has been designed and constructed to expose the physics models utilised, to handle complex geometries, and to enable its easy adaptation for optimal use in different sets of applications. The toolkit is the result of a worldwide collaboration of physicists and software engineers. It has been created exploiting software engineering and object-oriented technology and implemented in the C++ programming language. It has been used in applications in particle physics, nuclear physics, accelerator design, space engineering and medical physics.

  18. Geant4 - A Simulation Toolkit

    Energy Technology Data Exchange (ETDEWEB)

    Wright, Dennis H

    2002-08-09

    GEANT4 is a toolkit for simulating the passage of particles through matter. it includes a complete range of functionality including tracking, geometry, physics models and hits. The physics processes offered cover a comprehensive range, including electromagnetic, hadronic and optical processes, a large set of long-lived particles, materials and elements, over a wide energy range starting, in some cases, from 250 eV and extending in others to the TeV energy range. it has been designed and constructed to expose the physics models utilized, to handle complex geometries, and to enable its easy adaptation for optimal use in different sets of applications. The toolkit is the result of a worldwide collaboration of physicists and software engineers. It has been created exploiting software engineering and object-oriented technology and implemented in the C++ programming language. It has been used in applications in particle physics, nuclear physics, accelerator design, space engineering and medical physics.

  19. Geant4-DNA simulation of electron slowing-down spectra in liquid water

    Energy Technology Data Exchange (ETDEWEB)

    Incerti, S., E-mail: sebastien.incerti@tdt.edu.vn [Division of Nuclear Physics, Ton Duc Thang University, Tan Phong Ward, District 7, Ho Chi Minh City (Viet Nam); Faculty of Applied Sciences, Ton Duc Thang University, Tan Phong Ward, District 7, Ho Chi Minh City (Viet Nam); Univ. Bordeaux, CENBG, UMR 5797, F-33170, Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); Kyriakou, I. [Medical Physics Laboratory, University of Ioannina Medical School, 45110 Ioannina (Greece); Tran, H.N. [Division of Nuclear Physics, Ton Duc Thang University, Tan Phong Ward, District 7, Ho Chi Minh City (Viet Nam); Faculty of Applied Sciences, Ton Duc Thang University, Tan Phong Ward, District 7, Ho Chi Minh City (Viet Nam)

    2017-04-15

    This work presents the simulation of monoenergetic electron slowing-down spectra in liquid water by the Geant4-DNA extension of the Geant4 Monte Carlo toolkit (release 10.2p01). These spectra are simulated for several incident energies using the most recent Geant4-DNA physics models, and they are compared to literature data. The influence of Auger electron production is discussed. For the first time, a dedicated Geant4-DNA example allowing such simulations is described and is provided to Geant4 users, allowing further verification of Geant4-DNA track structure simulation capabilities.

  20. Integration of g4tools in Geant4

    International Nuclear Information System (INIS)

    Hřivnáčová, Ivana

    2014-01-01

    g4tools, that is originally part of the inlib and exlib packages, provides a very light and easy to install set of C++ classes that can be used to perform analysis in a Geant4 batch program. It allows to create and manipulate histograms and ntuples, and write them in supported file formats (ROOT, AIDA XML, CSV and HBOOK). It is integrated in Geant4 through analysis manager classes, thus providing a uniform interface to the g4tools objects and also hiding the differences between the classes for different supported output formats. Moreover, additional features, such as for example histogram activation or support for Geant4 units, are implemented in the analysis classes following users requests. A set of Geant4 user interface commands allows the user to create histograms and set their properties interactively or in Geant4 macros. g4tools was first introduced in the Geant4 9.5 release where its use was demonstrated in one basic example, and it is already used in a majority of the Geant4 examples within the Geant4 9.6 release. In this paper, we will give an overview and the present status of the integration of g4tools in Geant4 and report on upcoming new features.

  1. Creating and improving multi-threaded Geant4

    CERN Document Server

    Dong, Xin; Apostolakis, John; Jarp, Sverre; Nowak, Andrzej; Asai, Makoto; Brandt, Daniel

    2012-01-01

    We document the methods used to create the multi-threaded prototype Geant4MT from a sequential version of Geant4. We cover the Source-to-Source transformations applied, and discuss the process of verifying the correctness of the Geant4MT toolkit and applications based on it. Tools to ensure that the results of a transformed multi-threaded application are exactly equal to the original sequential version are under development. Stand-alone or simple applications can be adapted within 1-2 working days. Geant4MT is shown to scale linearly on an 80-core computer. In the special case of a single worker thread on one core, 30% overhead has been observed. We explain the reasons for this and the improvements introduced to reduce this overhead.

  2. The effects of nuclear data library processing on Geant4 and MCNP simulations of the thermal neutron scattering law

    Science.gov (United States)

    Hartling, K.; Ciungu, B.; Li, G.; Bentoumi, G.; Sur, B.

    2018-05-01

    Monte Carlo codes such as MCNP and Geant4 rely on a combination of physics models and evaluated nuclear data files (ENDF) to simulate the transport of neutrons through various materials and geometries. The grid representation used to represent the final-state scattering energies and angles associated with neutron scattering interactions can significantly affect the predictions of these codes. In particular, the default thermal scattering libraries used by MCNP6.1 and Geant4.10.3 do not accurately reproduce the ENDF/B-VII.1 model in simulations of the double-differential cross section for thermal neutrons interacting with hydrogen nuclei in a thin layer of water. However, agreement between model and simulation can be achieved within the statistical error by re-processing ENDF/B-VII.I thermal scattering libraries with the NJOY code. The structure of the thermal scattering libraries and sampling algorithms in MCNP and Geant4 are also reviewed.

  3. GEANT4: simulation for the next generation of HEP experiments

    International Nuclear Information System (INIS)

    Simone, Giani

    1996-01-01

    GEANT4 (RD44) is a world-wide collaboration of scientists aiming to create the detector simulation tool kit necessary for the next generation of HEP experiments. A large variety of requirements also come from heavy ions physics, CP violation physics, cosmic rays physics, medical applications and space science applications. In order to meet such requirements, a large degree of functionality and flexibility has to provided. GEANT4 is exploiting Object Oriented Technology to achieve these goals. The most relevant Object Oriented methodologies have been studied and a large number of tools and libraries have been investigated and evaluated. An overview of the GEANT4 analysis and design model will be given and the main components of the object models discussed. The main functionality of a first prototype will also be described. An overall view of the collaboration's structure and strategy will also be given. (author)

  4. Geant4 in Scientific Literature

    CERN Document Server

    Pia, M G; Bell, Z W; Dressendorfer, P V

    2009-01-01

    The Geant4 reference paper published in Nuclear Instruments and Methods A in 2003 has become the most cited publication in the whole Nuclear Science and Technology category of Thomson-Reuter's Journal Citation Reports. It is currently the second most cited article among the publications authored by two major research institutes, CERN and INFN. An overview of Geant4 presence (and absence) in scholarly literature is presented; the patterns of Geant4 citations are quantitatively examined and discussed.

  5. An Overview of the Geant4 Toolkit

    CERN Document Server

    Apostolakis, John

    2007-01-01

    Geant4 is a toolkit for the simulation of the transport of radiation trough matter. With a flexible kernel and choices between different physics modeling choices, it has been tailored to the requirements of a wide range of applications. With the toolkit a user can describe a setup's or detector's geometry and materials, navigate inside it, simulate the physical interactions using a choice of physics engines, underlying physics cross-sections and models, visualise and store results. Physics models describing electromagnetic and hadronic interactions are provided, as are decays and processes for optical photons. Several models, with different precision and performance are available for many processes. The toolkit includes coherent physics model configurations, which are called physics lists. Users can choose an existing physics list or create their own, depending on their requirements and the application area. A clear structure and readable code, enable the user to investigate the origin of physics results. App...

  6. GEANT 4.8.2, 9.2 and 9.4 simulations versus experimental proton energy loss in thick absorbers

    Energy Technology Data Exchange (ETDEWEB)

    Evseev, Ivan; Schelin, Hugo R.; Ahmann, Francielle; Milhoretto, Edney; Paschuk, Sergei A., E-mail: evseev@utfpr.edu.b, E-mail: schelin@utfpr.edu.b, E-mail: sergei@utfpr.edu.b [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil); Yevseyeva, Olga; Assis, Joaquim T. de; Ievsieieva, Ievgeniia, E-mail: yevseveva@iprj.uerj.b, E-mail: joaquim@iprj.uerj.b [Instituto Politecnico do Rio de Janeiro (IPRJ/UERJ), Nova Friburgo, RJ (Brazil). Dept. de Modelagem Computacional; Hormaza, Joel M., E-mail: jmesa@ibb.unesp.b [Universidade Estadual Paulista (IBB/UNESP), Botucatu, SP (Brazil). Inst. de Biociencias; Diaz, Katherin S. [Centro de Aplicaciones Tecnologicas y Desarrollo Nuclear, Havana (Cuba); Lopes, Ricardo T. [Coordenacao dos Programas de Pos-Graduacao de Engenharia (LIN/COPPE/UFRJ), RJ (Brazil). Lab. de Instrumentacao Nuclear

    2011-07-01

    Monte Carlo simulations are a powerful tool to estimate the proton energy loss and straggling in medical applications. The physics of proton interaction with matter for thick absorbers (like a human body) has a well-established theory for the so-called Bethe-Bloch domain, and the basic principles of Monte Carlo simulation for such processes are well known since the middle of the past century. However, in spite of GEANT4 has been validated against proton stopping powers from the NIST PSTAR, the evolution of the code leads to some result instability within the various code releases. In this work, we present the recent results for the comparison of our GEANT4 simulations against experimental proton energy loss for some thick absorbers. All the simulations were performed using the GEANT4 Hadrontherapy Advanced Example. The GEANT4 versions 4.8.2, 4.9.2, and 4.9.4 were tested with different simulation parameters, such as varied cut values. In addition to the Standard model, some other models for the electromagnetic processes from the GEANT4 Low Energy Extension Pack were tested as well. Experimental data were taken from for polyethylene, and from for aluminum and gold absorbers. The theoretical predictions for the spectra were calculated using the self-consistent Gaussian solution of the Boltzmann kinetic equation in the Fokker-Plank form. In order to compare the GEANT4 simulations with other popular codes, the same spectra were simulated by TRIM/SRIM2011 and MCNPX2.4.0. The simultaneous comparison of the results obtained for different materials at various initial proton energies were done using the reduced calibration curve approach. (author)

  7. Neutron transport simulation in high speed moving media using Geant4

    Science.gov (United States)

    Li, G.; Ciungu, B.; Harrisson, G.; Rogge, R. B.; Tun, Z.; van der Ende, B. M.; Zwiers, I.

    2017-12-01

    A method using Geant4 to simulate neutron transport in moving media is described. The method is implanted in the source code of the software since Geant4 does not intrinsically support a moving object. The simulation utilizes the existing physical model and data library in Geant4, combined with frame transformations to account for the effect of relative velocity between neutrons and the moving media. An example is presented involving a high speed rotating cylinder to verify this method and show the effect of moving media on neutron transport.

  8. CPU time optimization and precise adjustment of the Geant4 physics parameters for a VARIAN 2100 C/D gamma radiotherapy linear accelerator simulation using GAMOS

    Science.gov (United States)

    Arce, Pedro; Lagares, Juan Ignacio

    2018-02-01

    We have verified the GAMOS/Geant4 simulation model of a 6 MV VARIAN Clinac 2100 C/D linear accelerator by the procedure of adjusting the initial beam parameters to fit the percentage depth dose and cross-profile dose experimental data at different depths in a water phantom. Thanks to the use of a wide range of field sizes, from 2  ×  2 cm2 to 40  ×  40 cm2, a small phantom voxel size and high statistics, fine precision in the determination of the beam parameters has been achieved. This precision has allowed us to make a thorough study of the different physics models and parameters that Geant4 offers. The three Geant4 electromagnetic physics sets of models, i.e. Standard, Livermore and Penelope, have been compared to the experiment, testing the four different models of angular bremsstrahlung distributions as well as the three available multiple-scattering models, and optimizing the most relevant Geant4 electromagnetic physics parameters. Before the fitting, a comprehensive CPU time optimization has been done, using several of the Geant4 efficiency improvement techniques plus a few more developed in GAMOS.

  9. artG4: A Generic Framework for Geant4 Simulations

    Energy Technology Data Exchange (ETDEWEB)

    Arvanitis, Tasha [Harvey Mudd Coll.; Lyon, Adam [Fermilab

    2014-01-01

    A small experiment must devote its limited computing expertise to writing physics code directly applicable to the experiment. A software 'framework' is essential for providing an infrastructure that makes writing the physics-relevant code easy. In this paper, we describe a highly modular and easy to use framework for writing Geant4 based simulations called 'artg4'. This framework is a layer on top of the art framework.

  10. An Overview of the GEANT4 Toolkit

    International Nuclear Information System (INIS)

    Apostolakis, John; CERN; Wright, Dennis H.

    2007-01-01

    Geant4 is a toolkit for the simulation of the transport of radiation through matter. With a flexible kernel and choices between different physics modeling choices, it has been tailored to the requirements of a wide range of applications. With the toolkit a user can describe a setup's or detector's geometry and materials, navigate inside it, simulate the physical interactions using a choice of physics engines, underlying physics cross-sections and models, visualize and store results. Physics models describing electromagnetic and hadronic interactions are provided, as are decays and processes for optical photons. Several models, with different precision and performance are available for many processes. The toolkit includes coherent physics model configurations, which are called physics lists. Users can choose an existing physics list or create their own, depending on their requirements and the application area. A clear structure and readable code, enable the user to investigate the origin of physics results. Application areas include detector simulation and background simulation in High Energy Physics experiments, simulation of accelerator setups, studies in medical imaging and treatment, and the study of the effects of solar radiation on spacecraft instruments

  11. Lightgrid-an agile distributed computing architecture for Geant4

    International Nuclear Information System (INIS)

    Young, Jason; Perry, John O.; Jevremovic, Tatjana

    2010-01-01

    A light weight grid based computing architecture has been developed to accelerate Geant4 computations on a variety of network architectures. This new software is called LightGrid. LightGrid has a variety of features designed to overcome current limitations on other grid based computing platforms, more specifically, smaller network architectures. By focusing on smaller, local grids, LightGrid is able to simplify the grid computing process with minimal changes to existing Geant4 code. LightGrid allows for integration between Geant4 and MySQL, which both increases flexibility in the grid as well as provides a faster, reliable, and more portable method for accessing results than traditional data storage systems. This unique method of data acquisition allows for more fault tolerant runs as well as instant results from simulations as they occur. The performance increases brought along by using LightGrid allow simulation times to be decreased linearly. LightGrid also allows for pseudo-parallelization with minimal Geant4 code changes.

  12. Analysis of GEANT4 Physics List Properties in the 12 GeV MOLLER Simulation Framework

    Science.gov (United States)

    Haufe, Christopher; Moller Collaboration

    2013-10-01

    To determine the validity of new physics beyond the scope of the electroweak theory, nuclear physicists across the globe have been collaborating on future endeavors that will provide the precision needed to confirm these speculations. One of these is the MOLLER experiment - a low-energy particle experiment that will utilize the 12 GeV upgrade of Jefferson Lab's CEBAF accelerator. The motivation of this experiment is to measure the parity-violating asymmetry of scattered polarized electrons off unpolarized electrons in a liquid hydrogen target. This measurement would allow for a more precise determination of the electron's weak charge and weak mixing angle. While still in its planning stages, the MOLLER experiment requires a detailed simulation framework in order to determine how the project should be run in the future. The simulation framework for MOLLER, called ``remoll'', is written in GEANT4 code. As a result, the simulation can utilize a number of GEANT4 coded physics lists that provide the simulation with a number of particle interaction constraints based off of different particle physics models. By comparing these lists with one another using the data-analysis application ROOT, the most optimal physics list for the MOLLER simulation can be determined and implemented. This material is based upon work supported by the National Science Foundation under Grant No. 714001.

  13. Geant4 for the atlas electromagnetic calorimeter

    International Nuclear Information System (INIS)

    Kordas, K.; Parrour, G.; Simion, St.

    2001-04-01

    We have recently employed the Geant4 tool-kit for the simulation of the barrel part of the ATLAS electromagnetic calorimeter. The two approaches used for the description of this geometry are presented and compared. Subsequently, we test the new simulation tool against the predictions of Geant3, the previous generation of the Geant simulation. We do so for muons. With the caveat of some differences in the detector geometry implementations in Geant4 and Geant3, we also show some extremely preliminary results for electrons. A comparison between the two geometry models has shown that there are very small differences, which are under study, but in general the tailored geometry approach is proven sound. We also investigated a way to reduce significantly the memory usage of the straight-forward 'static' geometry description. Comparing Geant4 against Geant3, we find that the mean energy depositions for 50 and 100 GeV muons are in agreement between the two simulations, but the two yield significantly different distributions. Preliminary results on electrons are encouraging and we plan to study these particles next, including comparisons with test beam data. (authors)

  14. GEANT4 Tuning For pCT Development

    International Nuclear Information System (INIS)

    Yevseyeva, Olga; Assis, Joaquim T. de; Evseev, Ivan; Schelin, Hugo R.; Paschuk, Sergei A.; Milhoretto, Edney; Setti, Joao A. P.; Diaz, Katherin S.; Hormaza, Joel M.; Lopes, Ricardo T.

    2011-01-01

    Proton beams in medical applications deal with relatively thick targets like the human head or trunk. Thus, the fidelity of proton computed tomography (pCT) simulations as a tool for proton therapy planning depends in the general case on the accuracy of results obtained for the proton interaction with thick absorbers. GEANT4 simulations of proton energy spectra after passing thick absorbers do not agree well with existing experimental data, as showed previously. Moreover, the spectra simulated for the Bethe-Bloch domain showed an unexpected sensitivity to the choice of low-energy electromagnetic models during the code execution. These observations were done with the GEANT4 version 8.2 during our simulations for pCT. This work describes in more details the simulations of the proton passage through aluminum absorbers with varied thickness. The simulations were done by modifying only the geometry in the Hadrontherapy Example, and for all available choices of the Electromagnetic Physics Models. As the most probable reasons for these effects is some specific feature in the code, or some specific implicit parameters in the GEANT4 manual, we continued our study with version 9.2 of the code. Some improvements in comparison with our previous results were obtained. The simulations were performed considering further applications for pCT development.

  15. A Customizable GeantV Calorimeter Application

    CERN Document Server

    Schmitz, Ryan; Vallecorsa, Sofia; Novak, Mihaly; CERN. Geneva. EP Department

    2017-01-01

    A customizable calorimeter application was written in GeantV. This application includes a GeantV-native detector construction file as well as GeantV-native physics models and new data collection structures. Including these features makes this one of the first examples of a completely standalone GeantV application. A comparison to Geant4 was made which showed the consistency of the GeantV-native physics models included in this example. Finally, the workflow improvements made by the creation of this application are described.

  16. New evaluated neutron cross section libraries for the GEANT4 code

    International Nuclear Information System (INIS)

    Mendoza, E.; Cano-Ott, D.; Guerrero, C.; Capote, R.

    2012-04-01

    The so-called High Precision neutron physics model implemented in the GEANT4 simulation package allows simulating the transport of neutrons with energies up to 20 MeV. It relies on the G4NDL cross section libraries, prepared by the GEANT4 collaboration from evaluated cross section files and distributed freely together with the code. Even though the performance of the G4NDL library has been improved over the time, users running complex simulations which involve the transport of neutrons do need more flexibility, in particular when assessing the uncertainties in the simulation results due to the neutron (and hence the nuclear) data library used. For this reason, a software tool has been developed for transforming any evaluated neutron cross section library in the ENDF-6 format into the G4NDL format. Furthermore, eight different releases of ENDF-B, JEFF, JENDL, CENDL and BROND national libraries have been translated into the G4NDL format and are distributed by the IAEA nuclear data service at www-nds.iaea.org/geant4. In this way, GEANT4 users have access to the complete list of standard evaluated neutron data libraries when performing Monte Carlo simulations with GEANT4. Consistency checks and a first validation of the libraries have been made following the methods described in this report. (author)

  17. Comparison of scattering experiments using synchrotron radiation with Monte Carlo simulations using Geant4

    International Nuclear Information System (INIS)

    Gerlach, M.; Krumrey, M.; Cibik, L.; Mueller, P.; Ulm, G.

    2009-01-01

    Monte Carlo techniques are powerful tools to simulate the interaction of electromagnetic radiation with matter. One of the most widespread simulation program packages is Geant4. Almost all physical interaction processes can be included. However, it is not evident what accuracy can be obtained by a simulation. In this work, results of scattering experiments using monochromatized synchrotron radiation in the X-ray regime are quantitatively compared to the results of simulations using Geant4. Experiments were performed for various scattering foils made of different materials such as copper and gold. For energy-dispersive measurements of the scattered radiation, a cadmium telluride detector was used. The detector was fully characterized and calibrated with calculable undispersed as well as monochromatized synchrotron radiation. The obtained quantum efficiency and the response functions are in very good agreement with the corresponding Geant4 simulations. At the electron storage ring BESSY II the number of incident photons in the scattering experiments was measured with a photodiode that had been calibrated against a cryogenic radiometer, so that a direct comparison of scattering experiments with Monte Carlo simulations using Geant4 was possible. It was shown that Geant4 describes the photoeffect, including fluorescence as well as the Compton and Rayleigh scattering, with high accuracy, resulting in a deviation of typically less than 20%. Even polarization effects are widely covered by Geant4, and for Doppler broadening of Compton-scattered radiation the extension G4LECS can be included, but the fact that both features cannot be combined is a limitation. For most polarization-dependent simulations, good agreement with the experimental results was found, except for some orientations where Rayleigh scattering was overestimated in the simulation.

  18. Comparison of scattering experiments using synchrotron radiation with Monte Carlo simulations using Geant4

    Science.gov (United States)

    Gerlach, M.; Krumrey, M.; Cibik, L.; Müller, P.; Ulm, G.

    2009-09-01

    Monte Carlo techniques are powerful tools to simulate the interaction of electromagnetic radiation with matter. One of the most widespread simulation program packages is Geant4. Almost all physical interaction processes can be included. However, it is not evident what accuracy can be obtained by a simulation. In this work, results of scattering experiments using monochromatized synchrotron radiation in the X-ray regime are quantitatively compared to the results of simulations using Geant4. Experiments were performed for various scattering foils made of different materials such as copper and gold. For energy-dispersive measurements of the scattered radiation, a cadmium telluride detector was used. The detector was fully characterized and calibrated with calculable undispersed as well as monochromatized synchrotron radiation. The obtained quantum efficiency and the response functions are in very good agreement with the corresponding Geant4 simulations. At the electron storage ring BESSY II the number of incident photons in the scattering experiments was measured with a photodiode that had been calibrated against a cryogenic radiometer, so that a direct comparison of scattering experiments with Monte Carlo simulations using Geant4 was possible. It was shown that Geant4 describes the photoeffect, including fluorescence as well as the Compton and Rayleigh scattering, with high accuracy, resulting in a deviation of typically less than 20%. Even polarization effects are widely covered by Geant4, and for Doppler broadening of Compton-scattered radiation the extension G4LECS can be included, but the fact that both features cannot be combined is a limitation. For most polarization-dependent simulations, good agreement with the experimental results was found, except for some orientations where Rayleigh scattering was overestimated in the simulation.

  19. Comparison of scattering experiments using synchrotron radiation with Monte Carlo simulations using Geant4

    Energy Technology Data Exchange (ETDEWEB)

    Gerlach, M. [Physikalisch-Technische Bundesanstalt, Abbestr. 2-12, 10587 Berlin (Germany); Krumrey, M. [Physikalisch-Technische Bundesanstalt, Abbestr. 2-12, 10587 Berlin (Germany)], E-mail: Michael.Krumrey@ptb.de; Cibik, L.; Mueller, P.; Ulm, G. [Physikalisch-Technische Bundesanstalt, Abbestr. 2-12, 10587 Berlin (Germany)

    2009-09-11

    Monte Carlo techniques are powerful tools to simulate the interaction of electromagnetic radiation with matter. One of the most widespread simulation program packages is Geant4. Almost all physical interaction processes can be included. However, it is not evident what accuracy can be obtained by a simulation. In this work, results of scattering experiments using monochromatized synchrotron radiation in the X-ray regime are quantitatively compared to the results of simulations using Geant4. Experiments were performed for various scattering foils made of different materials such as copper and gold. For energy-dispersive measurements of the scattered radiation, a cadmium telluride detector was used. The detector was fully characterized and calibrated with calculable undispersed as well as monochromatized synchrotron radiation. The obtained quantum efficiency and the response functions are in very good agreement with the corresponding Geant4 simulations. At the electron storage ring BESSY II the number of incident photons in the scattering experiments was measured with a photodiode that had been calibrated against a cryogenic radiometer, so that a direct comparison of scattering experiments with Monte Carlo simulations using Geant4 was possible. It was shown that Geant4 describes the photoeffect, including fluorescence as well as the Compton and Rayleigh scattering, with high accuracy, resulting in a deviation of typically less than 20%. Even polarization effects are widely covered by Geant4, and for Doppler broadening of Compton-scattered radiation the extension G4LECS can be included, but the fact that both features cannot be combined is a limitation. For most polarization-dependent simulations, good agreement with the experimental results was found, except for some orientations where Rayleigh scattering was overestimated in the simulation.

  20. Validation of recent Geant4 physics models for application in carbon ion therapy

    CERN Document Server

    Lechner, A; Ivanchenko, V N

    2010-01-01

    Cancer treatment with energetic carbon ions has distinct advantages over proton or photon irradiation. In this paper we present a simulation model integrated into the Geant4 Monte Carlo toolkit (version 9.3) which enables the use of ICRU 73 stopping powers for ion transport calculations. For a few materials, revised ICRU 73 stopping power tables recently published by ICRU (P. Sigmund, A. Schinner, H. Paul, Errata and Addenda: ICRU Report 73 (Stopping of Ions Heavier than Helium), International Commission on Radiation Units and Measurements, 2009) were incorporated into Geant4, also covering media like water which are of importance in radiotherapeutical applications. We examine, with particular attention paid to the recent developments, the accuracy of current Geant4 models for simulating Bragg peak profiles of C-12 ions incident on water and polyethylene targets. Simulated dose distributions are validated against experimental data available in the literature, where the focus is on beam energies relevant to io...

  1. Comparison of CdZnTe neutron detector models using MCNP6 and Geant4

    Science.gov (United States)

    Wilson, Emma; Anderson, Mike; Prendergasty, David; Cheneler, David

    2018-01-01

    The production of accurate detector models is of high importance in the development and use of detectors. Initially, MCNP and Geant were developed to specialise in neutral particle models and accelerator models, respectively; there is now a greater overlap of the capabilities of both, and it is therefore useful to produce comparative models to evaluate detector characteristics. In a collaboration between Lancaster University, UK, and Innovative Physics Ltd., UK, models have been developed in both MCNP6 and Geant4 of Cadmium Zinc Telluride (CdZnTe) detectors developed by Innovative Physics Ltd. Herein, a comparison is made of the relative strengths of MCNP6 and Geant4 for modelling neutron flux and secondary γ-ray emission. Given the increasing overlap of the modelling capabilities of MCNP6 and Geant4, it is worthwhile to comment on differences in results for simulations which have similarities in terms of geometries and source configurations.

  2. SU-E-T-565: RAdiation Resistance of Cancer CElls Using GEANT4 DNA: RACE

    Energy Technology Data Exchange (ETDEWEB)

    Perrot, Y; Payno, H; Delage, E; Maigne, L [Clermont Universite, CNRS/IN2P3, Laboratoire de Physique Corpusculaire de Clermont-Ferrand, Aubiere (France); Incerti, S [Universite Bordeaux 1, CNRS/IN2P3, Centres d' Etudes Nucleaires de Bordeaux-Gradignan, Gradignan (France); Debiton, E; Peyrode, C; Chezal, J; Miot-Noirault, E; Degoul, F [Clermont Universite, Universite d' Auvergne, Imagerie Moleculaire et Therapie Vectorisee, INSERM U990, Centre Jean Perrin, Clermont-Ferrand (France)

    2014-06-01

    Purpose: The objective of the RACE project is to develop a comparison between Monte Carlo simulation using the Geant4-DNA toolkit and measurements of radiation damage on 3D melanoma and chondrosarcoma culture cells coupled with gadolinium nanoparticles. We currently expose the status of the developments regarding simulations. Methods: Monte Carlo studies are driven using the Geant4 toolkit and the Geant4-DNA extension. In order to model the geometry of a cell population, the opensource CPOP++ program is being developed for the geometrical representation of 3D cell populations including a specific cell mesh coupled with a multi-agent system. Each cell includes cytoplasm and nucleus. The correct modeling of the cell population has been validated with confocal microscopy images of spheroids. The Geant4 Livermore physics models are used to simulate the interactions of a 250 keV X-ray beam and the production of secondaries from gadolinium nanoparticles supposed to be fixed on the cell membranes. Geant4-DNA processes are used to simulate the interactions of charged particles with the cells. An atomistic description of the DNA molecule, from PDB (Protein Data Bank) files, is provided by the so-called PDB4DNA Geant4 user application we developed to score energy depositions in DNA base pairs and sugar-phosphate groups. Results: At the microscopic level, our simulations enable assessing microscopic energy distribution in each cell compartment of a realistic 3D cell population. Dose enhancement factors due to the presence of gadolinium nanoparticles can be estimated. At the nanometer scale, direct damages on nuclear DNA are also estimated. Conclusion: We successfully simulated the impact of direct radiations on a realistic 3D cell population model compatible with microdosimetry calculations using the Geant4-DNA toolkit. Upcoming validation and the future integration of the radiochemistry module of Geant4-DNA will propose to correlate clusters of ionizations with in vitro

  3. Object-oriented approach to preequilibrium and equilibrium decays in Geant4

    International Nuclear Information System (INIS)

    Lara, V.

    2001-01-01

    The Geant4 simulation toolkit provides a set of parameterized models that allow to model hadronic showers. However, in order to allow extrapolation beyond the experimental data and to offer an alternative set of models at conventional energies, Geant4 also provides a set of theory based hadronic shower models. We present the Object Oriented Design of a semiclassical exciton model for preequilibrium decays and a set of statistical models for deexcitation of compound nuclei. Our design follows the philosophy of hadronic models in Geant4, allowing for maximum of extendibility and customizability of the underlying physics by means of the use of abstract interfaces. We exploit advanced Software Engineering techniques and Object Oriented technology to achieve those goals. We present also a series of comparisons against experimental data being made in order to test the model. (orig.)

  4. SU-E-T-521: Investigation of the Uncertainties Involved in Secondary Neutron/gamma Production in Geant4/MCNP6 Monte Carlo Codes for Proton Therapy Application

    International Nuclear Information System (INIS)

    Mirzakhanian, L; Enger, S; Giusti, V

    2015-01-01

    Purpose: A major concern in proton therapy is the production of secondary neutrons causing secondary cancers, especially in young adults and children. Most utilized Monte Carlo codes in proton therapy are Geant4 and MCNP. However, the default versions of Geant4 and MCNP6 do not have suitable cross sections or physical models to properly handle secondary particle production in proton energy ranges used for therapy. In this study, default versions of Geant4 and MCNP6 were modified to better handle production of secondaries by adding the TENDL-2012 cross-section library. Methods: In-water proton depth-dose was measured at the “The Svedberg Laboratory” in Uppsala (Sweden). The proton beam was mono-energetic with mean energy of 178.25±0.2 MeV. The measurement set-up was simulated by Geant4 version 10.00 (default and modified version) and MCNP6. Proton depth-dose, primary and secondary particle fluence and neutron equivalent dose were calculated. In case of Geant4, the secondary particle fluence was filtered by all the physics processes to identify the main process responsible for the difference between the default and modified version. Results: The proton depth-dose curves and primary proton fluence show a good agreement between both Geant4 versions and MCNP6. With respect to the modified version, default Geant4 underestimates the production of secondary neutrons while overestimates that of gammas. The “ProtonInElastic” process was identified as the main responsible process for the difference between the two versions. MCNP6 shows higher neutron production and lower gamma production than both Geant4 versions. Conclusion: Despite the good agreement on the proton depth dose curve and primary proton fluence, there is a significant discrepancy on secondary neutron production between MCNP6 and both versions of Geant4. Further studies are thus in order to find the possible cause of this discrepancy or more accurate cross-sections/models to handle the nuclear

  5. GAMOS: A framework to do GEANT4 simulations in different physics fields with an user-friendly interface

    International Nuclear Information System (INIS)

    Arce, Pedro; Ignacio Lagares, Juan; Harkness, Laura; Pérez-Astudillo, Daniel; Cañadas, Mario; Rato, Pedro; Prado, María de; Abreu, Yamiel; Lorenzo, Gianluca de; Kolstein, Machiel; Díaz, Angelina

    2014-01-01

    GAMOS is a software system for GEANT4-based simulation. It comprises a framework, a set of components providing functionality to simulation applications on top of the GEANT4 toolkit, and a collection of ready-made applications. It allows to perform GEANT4-based simulations using a scripting language, without requiring the writing of C++ code. Moreover, GAMOS design allows the extension of the existing functionality through user-supplied C++ classes. The main characteristics of GAMOS and its embedded functionality are described

  6. Performance of GeantV EM Physics Models

    Energy Technology Data Exchange (ETDEWEB)

    Amadio, G.; et al.

    2016-10-14

    The recent progress in parallel hardware architectures with deeper vector pipelines or many-cores technologies brings opportunities for HEP experiments to take advantage of SIMD and SIMT computing models. Launched in 2013, the GeantV project studies performance gains in propagating multiple particles in parallel, improving instruction throughput and data locality in HEP event simulation on modern parallel hardware architecture. Due to the complexity of geometry description and physics algorithms of a typical HEP application, performance analysis is indispensable in identifying factors limiting parallel execution. In this report, we will present design considerations and preliminary computing performance of GeantV physics models on coprocessors (Intel Xeon Phi and NVidia GPUs) as well as on mainstream CPUs.

  7. Performance of GeantV EM Physics Models

    Science.gov (United States)

    Amadio, G.; Ananya, A.; Apostolakis, J.; Aurora, A.; Bandieramonte, M.; Bhattacharyya, A.; Bianchini, C.; Brun, R.; Canal, P.; Carminati, F.; Cosmo, G.; Duhem, L.; Elvira, D.; Folger, G.; Gheata, A.; Gheata, M.; Goulas, I.; Iope, R.; Jun, S. Y.; Lima, G.; Mohanty, A.; Nikitina, T.; Novak, M.; Pokorski, W.; Ribon, A.; Seghal, R.; Shadura, O.; Vallecorsa, S.; Wenzel, S.; Zhang, Y.

    2017-10-01

    The recent progress in parallel hardware architectures with deeper vector pipelines or many-cores technologies brings opportunities for HEP experiments to take advantage of SIMD and SIMT computing models. Launched in 2013, the GeantV project studies performance gains in propagating multiple particles in parallel, improving instruction throughput and data locality in HEP event simulation on modern parallel hardware architecture. Due to the complexity of geometry description and physics algorithms of a typical HEP application, performance analysis is indispensable in identifying factors limiting parallel execution. In this report, we will present design considerations and preliminary computing performance of GeantV physics models on coprocessors (Intel Xeon Phi and NVidia GPUs) as well as on mainstream CPUs.

  8. Performance of GeantV EM Physics Models

    CERN Document Server

    Amadio, G; Apostolakis, J; Aurora, A; Bandieramonte, M; Bhattacharyya, A; Bianchini, C; Brun, R; Canal P; Carminati, F; Cosmo, G; Duhem, L; Elvira, D; Folger, G; Gheata, A; Gheata, M; Goulas, I; Iope, R; Jun, S Y; Lima, G; Mohanty, A; Nikitina, T; Novak, M; Pokorski, W; Ribon, A; Seghal, R; Shadura, O; Vallecorsa, S; Wenzel, S; Zhang, Y

    2017-01-01

    The recent progress in parallel hardware architectures with deeper vector pipelines or many-cores technologies brings opportunities for HEP experiments to take advantage of SIMD and SIMT computing models. Launched in 2013, the GeantV project studies performance gains in propagating multiple particles in parallel, improving instruction throughput and data locality in HEP event simulation on modern parallel hardware architecture. Due to the complexity of geometry description and physics algorithms of a typical HEP application, performance analysis is indispensable in identifying factors limiting parallel execution. In this report, we will present design considerations and preliminary computing performance of GeantV physics models on coprocessors (Intel Xeon Phi and NVidia GPUs) as well as on mainstream CPUs.

  9. Implementation of mathematical phantom of hand and forearm in GEANT4 Monte Carlo code

    International Nuclear Information System (INIS)

    Pessanha, Paula Rocha; Queiroz Filho, Pedro Pacheco de; Santos, Denison de Souza

    2014-01-01

    In this work, the implementation of a hand and forearm Geant4 phantom code, for further evaluation of occupational exposure of ends of the radionuclides decay manipulated during procedures involving the use of injection syringe. The simulation model offered by Geant4 includes a full set of features, with the reconstruction of trajectories, geometries and physical models. For this work, the values calculated in the simulation are compared with the measurements rates by thermoluminescent dosimeters (TLDs) in physical phantom REMAB®. From the analysis of the data obtained through simulation and experimentation, of the 14 points studied, there was a discrepancy of only 8.2% of kerma values found, and these figures are considered compatible. The geometric phantom implemented in Geant4 Monte Carlo code was validated and can be used later for the evaluation of doses at ends

  10. Molecular scale track structure simulations in liquid water using the Geant4-DNA Monte-Carlo processes

    Czech Academy of Sciences Publication Activity Database

    Francis, Z.; Incerti, S.; Capra, R.; Mascialino, B.; Montarou, G.; Štěpán, Václav; Villagrasa, C.

    2011-01-01

    Roč. 69, č. 1 (2011), s. 220-226 ISSN 0969-8043 R&D Projects: GA MŠk OC09012 Institutional research plan: CEZ:AV0Z10480505 Keywords : Monte Carlo * Geant4 * Geant4 DNA * microdosimetry * cross sections Subject RIV: BO - Biophysics Impact factor: 1.172, year: 2011

  11. A Geant4 simulation package for the SAGE spectrometer

    International Nuclear Information System (INIS)

    Papadakis, P; Cox, D M; Butler, P A; Herzberg, R-D; Pakarinen, J; Konki, J; Greenlees, P T; Hauschild, K; Rahkila, P; Sandzelius, M; Sorri, J

    2012-01-01

    A comprehensive Geant4 simulation was built for the SAGE spectrometer. The simulation package includes the silicon and germanium detectors, the mechanical structure and the electromagnetic fields present in SAGE. This simulation can be used for making predictions through simulating experiments and for comparing simulated and experimental data to better understand the underlying physics.

  12. Calculation of neutron fluence to dose equivalent conversion coefficients using GEANT4; Calculo de coeficientes de fluencia de neutrons para equivalente de dose individual utilizando o GEANT4

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, Rosane M.; Santos, Denison de S.; Queiroz Filho, Pedro P. de; Mauricio, CLaudia L.P.; Silva, Livia K. da; Pessanha, Paula R., E-mail: rosanemribeiro@oi.com.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2014-07-01

    Fluence to dose equivalent conversion coefficients provide the basis for the calculation of area and personal monitors. Recently, the ICRP has started a revision of these coefficients, including new Monte Carlo codes for benchmarking. So far, little information is available about neutron transport below 10 MeV in tissue-equivalent (TE) material performed with Monte Carlo GEANT4 code. The objective of this work is to calculate neutron fluence to personal dose equivalent conversion coefficients, H{sub p} (10)/Φ, with GEANT4 code. The incidence of monoenergetic neutrons was simulated as an expanded and aligned field, with energies ranging between thermal neutrons to 10 MeV on the ICRU slab of dimension 30 x 30 x 15 cm{sup 3}, composed of 76.2% of oxygen, 10.1% of hydrogen, 11.1% of carbon and 2.6% of nitrogen. For all incident energy, a cylindrical sensitive volume is placed at a depth of 10 mm, in the largest surface of the slab (30 x 30 cm{sup 2}). Physic process are included for neutrons, photons and charged particles, and calculations are made for neutrons and secondary particles which reach the sensitive volume. Results obtained are thus compared with values published in ICRP 74. Neutron fluence in the sensitive volume was calculated for benchmarking. The Monte Carlo GEANT4 code was found to be appropriate to calculate neutron doses at energies below 10 MeV correctly. (author)

  13. Geant4-DNA track-structure simulations for gold nanoparticles: The importance of electron discrete models in nanometer volumes.

    Science.gov (United States)

    Sakata, Dousatsu; Kyriakou, Ioanna; Okada, Shogo; Tran, Hoang N; Lampe, Nathanael; Guatelli, Susanna; Bordage, Marie-Claude; Ivanchenko, Vladimir; Murakami, Koichi; Sasaki, Takashi; Emfietzoglou, Dimitris; Incerti, Sebastien

    2018-05-01

    Gold nanoparticles (GNPs) are known to enhance the absorbed dose in their vicinity following photon-based irradiation. To investigate the therapeutic effectiveness of GNPs, previous Monte Carlo simulation studies have explored GNP dose enhancement using mostly condensed-history models. However, in general, such models are suitable for macroscopic volumes and for electron energies above a few hundred electron volts. We have recently developed, for the Geant4-DNA extension of the Geant4 Monte Carlo simulation toolkit, discrete physics models for electron transport in gold which include the description of the full atomic de-excitation cascade. These models allow event-by-event simulation of electron tracks in gold down to 10 eV. The present work describes how such specialized physics models impact simulation-based studies on GNP-radioenhancement in a context of x-ray radiotherapy. The new discrete physics models are compared to the Geant4 Penelope and Livermore condensed-history models, which are being widely used for simulation-based NP radioenhancement studies. An ad hoc Geant4 simulation application has been developed to calculate the absorbed dose in liquid water around a GNP and its radioenhancement, caused by secondary particles emitted from the GNP itself, when irradiated with a monoenergetic electron beam. The effect of the new physics models is also quantified in the calculation of secondary particle spectra, when originating in the GNP and when exiting from it. The new physics models show similar backscattering coefficients with the existing Geant4 Livermore and Penelope models in large volumes for 100 keV incident electrons. However, in submicron sized volumes, only the discrete models describe the high backscattering that should still be present around GNPs at these length scales. Sizeable differences (mostly above a factor of 2) are also found in the radial distribution of absorbed dose and secondary particles between the new and the existing Geant4

  14. Implementation of the n-body Monte-Carlo event generator into the Geant4 toolkit for photonuclear studies

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Wen, E-mail: wenluo-ok@163.com [School of Nuclear Science and Technology, University of South China, Hengyang 421001 (China); Lan, Hao-yang [School of Nuclear Science and Technology, University of South China, Hengyang 421001 (China); Xu, Yi; Balabanski, Dimiter L. [Extreme Light Infrastructure-Nuclear Physics, “Horia Hulubei” National Institute for Physics and Nuclear Engineering (IFIN-HH), 30 Reactorului, 077125 Bucharest-Magurele (Romania)

    2017-03-21

    A data-based Monte Carlo simulation algorithm, Geant4-GENBOD, was developed by coupling the n-body Monte-Carlo event generator to the Geant4 toolkit, aiming at accurate simulations of specific photonuclear reactions for diverse photonuclear physics studies. Good comparisons of Geant4-GENBOD calculations with reported measurements of photo-neutron production cross-sections and yields, and with reported energy spectra of the {sup 6}Li(n,α)t reaction were performed. Good agreements between the calculations and experimental data were found and the validation of the developed program was verified consequently. Furthermore, simulations for the {sup 92}Mo(γ,p) reaction of astrophysics relevance and photo-neutron production of {sup 99}Mo/{sup 99m}Tc and {sup 225}Ra/{sup 225}Ac radioisotopes were investigated, which demonstrate the applicability of this program. We conclude that the Geant4-GENBOD is a reliable tool for study of the emerging experiment programs at high-intensity γ-beam laboratories, such as the Extreme Light Infrastructure – Nuclear Physics facility and the High Intensity Gamma-Ray Source at Duke University.

  15. Calculation of neutron fluence to dose equivalent conversion coefficients using GEANT4

    International Nuclear Information System (INIS)

    Ribeiro, Rosane M.; Santos, Denison de S.; Queiroz Filho, Pedro P. de; Mauricio, CLaudia L.P.; Silva, Livia K. da; Pessanha, Paula R.

    2014-01-01

    Fluence to dose equivalent conversion coefficients provide the basis for the calculation of area and personal monitors. Recently, the ICRP has started a revision of these coefficients, including new Monte Carlo codes for benchmarking. So far, little information is available about neutron transport below 10 MeV in tissue-equivalent (TE) material performed with Monte Carlo GEANT4 code. The objective of this work is to calculate neutron fluence to personal dose equivalent conversion coefficients, H p (10)/Φ, with GEANT4 code. The incidence of monoenergetic neutrons was simulated as an expanded and aligned field, with energies ranging between thermal neutrons to 10 MeV on the ICRU slab of dimension 30 x 30 x 15 cm 3 , composed of 76.2% of oxygen, 10.1% of hydrogen, 11.1% of carbon and 2.6% of nitrogen. For all incident energy, a cylindrical sensitive volume is placed at a depth of 10 mm, in the largest surface of the slab (30 x 30 cm 2 ). Physic process are included for neutrons, photons and charged particles, and calculations are made for neutrons and secondary particles which reach the sensitive volume. Results obtained are thus compared with values published in ICRP 74. Neutron fluence in the sensitive volume was calculated for benchmarking. The Monte Carlo GEANT4 code was found to be appropriate to calculate neutron doses at energies below 10 MeV correctly. (author)

  16. Optimization of GEANT4 settings for Proton Pencil Beam Scanning simulations using GATE

    Energy Technology Data Exchange (ETDEWEB)

    Grevillot, Loic, E-mail: loic.grevillot@gmail.co [Universite de Lyon, F-69622 Lyon (France); Creatis, CNRS UMR 5220, F-69622 Villeurbanne (France); Centre de Lutte Contre le Cancer Leon Berard, F-69373 Lyon (France); IBA, B-1348 Louvain-la-Neuve (Belgium); Frisson, Thibault [Universite de Lyon, F-69622 Lyon (France); Creatis, CNRS UMR 5220, F-69622 Villeurbanne (France); Centre de Lutte Contre le Cancer Leon Berard, F-69373 Lyon (France); Zahra, Nabil [Universite de Lyon, F-69622 Lyon (France); IPNL, CNRS UMR 5822, F-69622 Villeurbanne (France); Centre de Lutte Contre le Cancer Leon Berard, F-69373 Lyon (France); Bertrand, Damien; Stichelbaut, Frederic [IBA, B-1348 Louvain-la-Neuve (Belgium); Freud, Nicolas [Universite de Lyon, F-69622 Lyon (France); CNDRI, INSA-Lyon, F-69621 Villeurbanne Cedex (France); Sarrut, David [Universite de Lyon, F-69622 Lyon (France); Creatis, CNRS UMR 5220, F-69622 Villeurbanne (France); Centre de Lutte Contre le Cancer Leon Berard, F-69373 Lyon (France)

    2010-10-15

    This study reports the investigation of different GEANT4 settings for proton therapy applications in the context of Treatment Planning System comparisons. The GEANT4.9.2 release was used through the GATE platform. We focused on the Pencil Beam Scanning delivery technique, which allows for intensity modulated proton therapy applications. The most relevant options and parameters (range cut, step size, database binning) for the simulation that influence the dose deposition were investigated, in order to determine a robust, accurate and efficient simulation environment. In this perspective, simulations of depth-dose profiles and transverse profiles at different depths and energies between 100 and 230 MeV have been assessed against reference measurements in water and PMMA. These measurements were performed in Essen, Germany, with the IBA dedicated Pencil Beam Scanning system, using Bragg-peak chambers and radiochromic films. GEANT4 simulations were also compared to the PHITS.2.14 and MCNPX.2.5.0 Monte Carlo codes. Depth-dose simulations reached 0.3 mm range accuracy compared to NIST CSDA ranges, with a dose agreement of about 1% over a set of five different energies. The transverse profiles simulated using the different Monte Carlo codes showed discrepancies, with up to 15% difference in beam widening between GEANT4 and MCNPX in water. A 8% difference between the GEANT4 multiple scattering and single scattering algorithms was observed. The simulations showed the inability of reproducing the measured transverse dose spreading with depth in PMMA, corroborating the fact that GEANT4 underestimates the lateral dose spreading. GATE was found to be a very convenient simulation environment to perform this study. A reference physics-list and an optimized parameters-list have been proposed. Satisfactory agreement against depth-dose profiles measurements was obtained. The simulation of transverse profiles using different Monte Carlo codes showed significant deviations. This point

  17. Verification of Electromagnetic Physics Models for Parallel Computing Architectures in the GeantV Project

    Energy Technology Data Exchange (ETDEWEB)

    Amadio, G.; et al.

    2017-11-22

    An intensive R&D and programming effort is required to accomplish new challenges posed by future experimental high-energy particle physics (HEP) programs. The GeantV project aims to narrow the gap between the performance of the existing HEP detector simulation software and the ideal performance achievable, exploiting latest advances in computing technology. The project has developed a particle detector simulation prototype capable of transporting in parallel particles in complex geometries exploiting instruction level microparallelism (SIMD and SIMT), task-level parallelism (multithreading) and high-level parallelism (MPI), leveraging both the multi-core and the many-core opportunities. We present preliminary verification results concerning the electromagnetic (EM) physics models developed for parallel computing architectures within the GeantV project. In order to exploit the potential of vectorization and accelerators and to make the physics model effectively parallelizable, advanced sampling techniques have been implemented and tested. In this paper we introduce a set of automated statistical tests in order to verify the vectorized models by checking their consistency with the corresponding Geant4 models and to validate them against experimental data.

  18. Geant4 hadronic and electromagnetic validation tests in LHCb

    CERN Document Server

    Griffith, Peter Noel

    2016-01-01

    LHCb uses Geant4 to simulate the interactions of particles with the detector material and components. The simulation response can vary significantly due to modification of material description, of detector geometry, or of the Geant4 toolkit itself. Therefore, an extensive variety of tools have been developed to study the effects of Geant4 modification on the LHCb simulation framework and on stand-alone environments within the LHCb software infrastructure. These tools have proven to be very effective for investigating new and alternative models provided by Geant4, and also in identifying and fixing anomalous behaviours that arise from changes. The next goal is to have these validation tests run autonomously and periodically, alerting the relevant users when problems are detected. Quick and easy comparison of the results from different software versions and simulation models will be made possible through the web interface of the LHCb Performance and Regression testing system, LHCbPR.

  19. Estimated Visualization of Dose Calculation with GEANT4 in Medical Linac

    International Nuclear Information System (INIS)

    Kim, Jhin Kee; Kim, Bu Gil; Lee, Jeong Ok; Kang, Jeong Ku; Oh, Young Kee; Jeong, Dong Hyeok; Kim, Jeong Kee

    2011-01-01

    Geant4 is a toolkit used to simulate the pass age of particles through matter. Recently, it has been used in many medical physics applications. In radiotherapy, positron emission tomography, and magnetic resonance tomography, Geant4 has been applied to accurately simulate the propagation of particles and the interaction of particles, not only with medical devices, but also with patient's phantoms.1,2 Many researchers try to use patient's image data to calculate the dose. The use of DICOM images files to simulate is desired. We construct detector with parameterized volume for Geant4 simulations, which can be applied to simulations using DICOM data as the input.We try to apply this code to the patient's DICOM images to simulate the propagation and interaction of the particles. So we can calculate the absorbed dose of the patient. In this study, the used visualization tool is called gMocren. The purpose of the present paper is to verify a volume visualization tool that simultaneously displays both the complex patient data and the simulated dose distribution with real patient's DICOM data. We applied a volume visualization tool for GEANT4 simulation. We developed to create the each voxel's dose tables of the every slices and review the distribution with DICOM file, gMocren is very convenience tool but provide only qualitative analysis. We need more enhanced functions to display contour like RTP and utility program to create dose table in every points.

  20. GEANT4 simulations for Proton computed tomography applications

    International Nuclear Information System (INIS)

    Yevseyeva, Olga; Assis, Joaquim T. de; Evseev, Ivan; Schelin, Hugo R.; Shtejer Diaz, Katherin; Lopes, Ricardo T.

    2011-01-01

    Proton radiation therapy is a highly precise form of cancer treatment. In existing proton treatment centers, dose calculations are performed based on X-ray computed tomography (CT). Alternatively, one could image the tumor directly with proton CT (pCT). Proton beams in medical applications deal with relatively thick targets like the human head or trunk. Thus, the fidelity of proton computed tomography (pCT) simulations as a tool for proton therapy planning depends in the general case on the accuracy of results obtained for the proton interaction with thick absorbers. GEANT4 simulations of proton energy spectra after passing thick absorbers do not agree well with existing experimental data, as showed previously. The spectra simulated for the Bethe-Bloch domain showed an unexpected sensitivity to the choice of low-energy electromagnetic models during the code execution. These observations were done with the GEANT4 version 8.2 during our simulations for pCT. This work describes in more details the simulations of the proton passage through gold absorbers with varied thickness. The simulations were done by modifying only the geometry in the Hadron therapy Example, and for all available choices of the Electromagnetic Physics Models. As the most probable reasons for these effects is some specific feature in the code or some specific implicit parameters in the GEANT4 manual, we continued our study with version 9.2 of the code. Some improvements in comparison with our previous results were obtained. The simulations were performed considering further applications for pCT development. The authors want to thank CNPq, CAPES and 'Fundacao Araucaria' for financial support of this work. (Author)

  1. Test of GEANT3 and GEANT4 nuclear models for 160 MeV protons stopping in CH2

    International Nuclear Information System (INIS)

    Paganetti, H.; Gottschalk, B.

    2003-01-01

    Monte Carlo simulations are used for many problems in proton radiation therapy, some of which are sensitive to the nuclear interaction model. The available models have been little tested in the regime of interest, namely in their ability to predict the secondary particle yield, including their angle and energy, when 70-250 MeV protons stop in various materials. The present study provides one such test in carbon, complementing a previous one in copper. Using a multilayer Faraday cup we have measured the projected range distribution of charged nuclear secondaries from 160 MeV protons stopping in polyethylene (CH 2 ). To test the popular GEANT Monte Carlo we have simulated the experiment with GEANT3 using the 'Gheisha' (default) and 'Fluka' models and with GEANT4.5 using the 'low-energy' and 'precompound' models. The GEANT3/Fluka and GEANT4/precompound simulations agree moderately well with the observed range distribution. The data are given in a convenient form for testing other Monte Carlo programs

  2. Performance Evaluation of Multithreaded Geant4 Simulations Using an Intel Xeon Phi Cluster

    Directory of Open Access Journals (Sweden)

    P. Schweitzer

    2015-01-01

    Full Text Available The objective of this study is to evaluate the performances of Intel Xeon Phi hardware accelerators for Geant4 simulations, especially for multithreaded applications. We present the complete methodology to guide users for the compilation of their Geant4 applications on Phi processors. Then, we propose series of benchmarks to compare the performance of Xeon CPUs and Phi processors for a Geant4 example dedicated to the simulation of electron dose point kernels, the TestEm12 example. First, we compare a distributed execution of a sequential version of the Geant4 example on both architectures before evaluating the multithreaded version of the Geant4 example. If Phi processors demonstrated their ability to accelerate computing time (till a factor 3.83 when distributing sequential Geant4 simulations, we do not reach the same level of speedup when considering the multithreaded version of the Geant4 example.

  3. Simulating response functions and pulse shape discrimination for organic scintillation detectors with Geant4

    Energy Technology Data Exchange (ETDEWEB)

    Hartwig, Zachary S., E-mail: hartwig@psfc.mit.edu [Department of Nuclear Science and Engineering, MIT, Cambridge MA (United States); Gumplinger, Peter [TRIUMF, Vancouver, BC (Canada)

    2014-02-11

    We present new capabilities of the Geant4 toolkit that enable the precision simulation of organic scintillation detectors within a comprehensive Monte Carlo code for the first time. As of version 10.0-beta, the Geant4 toolkit models the data-driven photon production from any user-defined scintillator, photon transportation through arbitrarily complex detector geometries, and time-resolved photon detection at the light readout device. By fully specifying the optical properties and geometrical configuration of the detector, the user can simulate response functions, photon transit times, and pulse shape discrimination. These capabilities enable detector simulation within a larger experimental environment as well as computationally evaluating novel scintillators, detector geometry, and light readout configurations. We demonstrate agreement of Geant4 with the NRESP7 code and with experiments for the spectroscopy of neutrons and gammas in the ranges 0–20 MeV and 0.511–1.274 MeV, respectively, using EJ301-based organic scintillation detectors. We also show agreement between Geant4 and experimental modeling of the particle-dependent detector pulses that enable simulated pulse shape discrimination. -- Highlights: • New capabilities enable the modeling of organic scintillation detectors in Geant4. • Detector modeling of complex scintillators, geometries, and light readout. • Enables particle- and energy-dependent production of scintillation photons. • Provides ability to generate response functions with precise optical physics. • Provides ability to computationally evaluate pulse shape discrimination.

  4. MCNPX and GEANT4 simulation of γ-ray polymeric shields

    Indian Academy of Sciences (India)

    However, both methods need benchmarking with experimental or standard data. Monte ... elements as it was defined for MCNPX and GEANT4 input materials. ... In GEANT4, photon and neutron libraries were implemented using EMLOW6.19.

  5. Geant4-DNA coupling and validation in the GATE Monte Carlo platform for DNA molecules irradiation in a calculation grid environment

    International Nuclear Information System (INIS)

    Pham, Quang Trung

    2014-01-01

    The Monte Carlo simulation methods are successfully being used in various areas of medical physics but also at different scales, for example, from the radiation therapy treatment planning systems to the prediction of the effects of radiation in cancer cells. The Monte Carlo simulation platform GATE based on the Geant4 tool-kit offers features dedicated to simulations in medical physics (nuclear medicine and radiotherapy). For radiobiology applications, the Geant4-DNA physical models are implemented to track particles till very low energy (eV) and are adapted for estimation of micro-dosimetric quantities. In order to implement a multi-scale Monte Carlo platform, we first validated the physical models of Geant4-DNA, and integrated them into GATE. Finally, we validated this implementation in the context of radiation therapy and proton therapy. In order to validate the Geant4-DNA physical models, dose point kernels for monoenergetic electrons (10 keV to 100 keV) were simulated using the physical models of Geant4-DNA and were compared to those simulated with Geant4 Standard physical models and another Monte Carlo code EGSnrc. The range and the stopping powers of electrons (7.4 eV to 1 MeV) and protons (1 keV to 100 MeV) calculated with GATE/Geant4-DNA were then compared with literature. We proposed to simulate with the GATE platform the impact of clinical and preclinical beams on cellular DNA. We modeled a clinical proton beam of 193.1 MeV, 6 MeV clinical electron beam and a X-ray irradiator beam. The beams models were validated by comparing absorbed dose computed and measured in liquid water. Then, the beams were used to calculate the frequency of energy deposits in DNA represented by different geometries. First, the DNA molecule was represented by small cylinders: 2 nm x 2 nm (∼10 bp), 5 nm x 10 nm (nucleosome) and 25 nm x 25 nm (chromatin fiber). All these cylinders were placed randomly in a sphere of liquid water (500 nm radius). Then we reconstructed the DNA

  6. An XML description of detector geometries for GEANT4

    International Nuclear Information System (INIS)

    Figgins, J.; Walker, B.; Comfort, J.R.

    2006-01-01

    A code has been developed that enables the geometry of detectors to be specified easily and flexibly in the XML language, for use in the Monte Carlo program GEANT4. The user can provide clear documentation of the geometry without being proficient in the C++ language of GEANT4. The features and some applications are discussed

  7. Monte Carlo calculations of thermal neutron capture in gadolinium: a comparison of GEANT4 and MCNP with measurements.

    Science.gov (United States)

    Enger, Shirin A; Munck af Rosenschöld, Per; Rezaei, Arash; Lundqvist, Hans

    2006-02-01

    GEANT4 is a Monte Carlo code originally implemented for high-energy physics applications and is well known for particle transport at high energies. The capacity of GEANT4 to simulate neutron transport in the thermal energy region is not equally well known. The aim of this article is to compare MCNP, a code commonly used in low energy neutron transport calculations and GEANT4 with experimental results and select the suitable code for gadolinium neutron capture applications. To account for the thermal neutron scattering from chemically bound atoms [S(alpha,beta)] in biological materials a comparison of thermal neutron fluence in tissue-like poly(methylmethacrylate) phantom is made with MCNP4B, GEANT4 6.0 patch1, and measurements from the neutron capture therapy (NCT) facility at the Studsvik, Sweden. The fluence measurements agreed with MCNP calculated results considering S(alpha,beta). The location of the thermal neutron peak calculated with MCNP without S(alpha,beta) and GEANT4 is shifted by about 0.5 cm towards a shallower depth and is 25%-30% lower in amplitude. Dose distribution from the gadolinium neutron capture reaction is then simulated by MCNP and compared with measured data. The simulations made by MCNP agree well with experimental results. As long as thermal neutron scattering from chemically bound atoms are not included in GEANT4 it is not suitable for NCT applications.

  8. Geant4 Developments for the Radon Electric Dipole Moment Search at TRIUMF

    Science.gov (United States)

    Rand, E. T.; Bangay, J. C.; Bianco, L.; Dunlop, R.; Finlay, P.; Garrett, P. E.; Leach, K. G.; Phillips, A. A.; Sumithrarachchi, C. S.; Svensson, C. E.; Wong, J.

    2011-09-01

    An experiment is being developed at TRIUMF to search for a time-reversal violating electric dipole moment (EDM) in odd-A isotopes of Rn. Extensive simulations of the experiment are being performed with GEANT4 to study the backgrounds and sensitivity of the proposed measurement technique involving the detection of γ rays emitted following the β decay of polarized Rn nuclei. GEANT4 developments for the RnEDM experiment include both realistic modelling of the detector geometry and full tracking of the radioactive β, γ, internal conversion, and x-ray processes, including the γ-ray angular distributions essential for measuring an atomic EDM.

  9. Geant4-related R&D for new particle transport methods

    CERN Document Server

    Augelli, M; Evans, T; Gargioni, E; Hauf, S; Kim, C H; Kuster, M; Pia, M G; Filho, P Queiroz; Quintieri, L; Saracco, P; Santos, D Souza; Weidenspointner, G; Zoglauer, A

    2009-01-01

    A R&D project has been launched in 2009 to address fundamental methods in radiation transport simulation and revisit Geant4 kernel design to cope with new experimental requirements. The project focuses on simulation at different scales in the same experimental environment: this set of problems requires new methods across the current boundaries of condensed-random-walk and discrete transport schemes. An exploration is also foreseen about exploiting and extending already existing Geant4 features to apply Monte Carlo and deterministic transport methods in the same simulation environment. An overview of this new R&D associated with Geant4 is presented, together with the first developments in progress.

  10. SU-E-T-347: Validation of the Condensed History Algorithm of Geant4 Using the Fano Test

    International Nuclear Information System (INIS)

    Lee, H; Mathis, M; Sawakuchi, G

    2014-01-01

    Purpose: To validate the condensed history algorithm and physics of the Geant4 Monte Carlo toolkit for simulations of ionization chambers (ICs). This study is the first step to validate Geant4 for calculations of photon beam quality correction factors under the presence of a strong magnetic field for magnetic resonance guided linac system applications. Methods: The electron transport and boundary crossing algorithms of Geant4 version 9.6.p02 were tested under Fano conditions using the Geant4 example/application FanoCavity. User-defined parameters of the condensed history and multiple scattering algorithms were investigated under Fano test conditions for three scattering models (physics lists): G4UrbanMscModel95 (PhysListEmStandard-option3), G4GoudsmitSaundersonMsc (PhysListEmStandard-GS), and G4WentzelVIModel/G4CoulombScattering (PhysListEmStandard-WVI). Simulations were conducted using monoenergetic photon beams, ranging from 0.5 to 7 MeV and emphasizing energies from 0.8 to 3 MeV. Results: The GS and WVI physics lists provided consistent Fano test results (within ±0.5%) for maximum step sizes under 0.01 mm at 1.25 MeV, with improved performance at 3 MeV (within ±0.25%). The option3 physics list provided consistent Fano test results (within ±0.5%) for maximum step sizes above 1 mm. Optimal parameters for the option3 physics list were 10 km maximum step size with default values for other user-defined parameters: 0.2 dRoverRange, 0.01 mm final range, 0.04 range factor, 2.5 geometrical factor, and 1 skin. Simulations using the option3 physics list were ∼70 – 100 times faster compared to GS and WVI under optimal parameters. Conclusion: This work indicated that the option3 physics list passes the Fano test within ±0.5% when using a maximum step size of 10 km for energies suitable for IC calculations in a 6 MV spectrum without extensive computational times. Optimal user-defined parameters using the option3 physics list will be used in future IC simulations to

  11. The Inner Detector software moves to Geant4

    CERN Multimedia

    Elsing, M

    2004-01-01

    2004 is a year of change and of several major milestones for the Inner Detector software. The first of these milestones was met in March when a set of test events was successfully processed through Geant4 and afterwards through the full Inner Detector offline software chain. In the picture, a reconstructed single muon event from this test sample is displayed in different projections. Even though this looks almost trivial, it required the successful integration of several new software components besides Geant4 into the Inner Detector code. A new ATLAS wide Detector Description software package called GeoModel has been fully deployed in the Inner Detector as the single source of geometry information for both the simulation and the reconstruction. New code to emulate the digitization for all detectors and a new data model have been put in place to cope with the new simulation input. And finally the two major offline reconstruction packages, namely xKalman and iPatRec, were migrated to use the new Inner Detector ...

  12. A tool to convert CAD models for importation into Geant4

    Science.gov (United States)

    Vuosalo, C.; Carlsmith, D.; Dasu, S.; Palladino, K.; LUX-ZEPLIN Collaboration

    2017-10-01

    The engineering design of a particle detector is usually performed in a Computer Aided Design (CAD) program, and simulation of the detector’s performance can be done with a Geant4-based program. However, transferring the detector design from the CAD program to Geant4 can be laborious and error-prone. SW2GDML is a tool that reads a design in the popular SOLIDWORKS CAD program and outputs Geometry Description Markup Language (GDML), used by Geant4 for importing and exporting detector geometries. Other methods for outputting CAD designs are available, such as the STEP format, and tools exist to convert these formats into GDML. However, these conversion methods produce very large and unwieldy designs composed of tessellated solids that can reduce Geant4 performance. In contrast, SW2GDML produces compact, human-readable GDML that employs standard geometric shapes rather than tessellated solids. This paper will describe the development and current capabilities of SW2GDML and plans for its enhancement. The aim of this tool is to automate importation of detector engineering models into Geant4-based simulation programs to support rapid, iterative cycles of detector design, simulation, and optimization.

  13. CHIPS_TPT models for exclusive Geant4 simulation of neutron-nuclear reactions at low energies

    Directory of Open Access Journals (Sweden)

    Kosov Mikhail V.

    2014-03-01

    Full Text Available A novel TPT code (Toolkit for Particle Transport, which is included in CHIPS_TPT physics list for Geant4 simulations, is briefly overviewed. Underlying concept of exclusive modelling is introduced and its beneficial features are illustrated with several examples. Widely used neutron Monte Carlo codes, MCNP and Geant4/HP, are based on inclusive algorithms that independently model neutron state change and secondary particles production while tracking. The exclusive approach implemented in TPT overcomes this unphysical separation and makes it possible to allow for kinematic restrictions as well as correlated emission of gamma-rays and secondaries.

  14. Refactoring, reengineering and evolution: paths to Geant4 uncertainty quantification and performance improvement

    International Nuclear Information System (INIS)

    Batič, M; Hoff, G; Pia, M G; Saracco, P; Begalli, M; Han, M; Kim, C H; Seo, H; Hauf, S; Kuster, M; Weidenspointner, G; Zoglauer, A

    2012-01-01

    Ongoing investigations for the improvement of Geant4 accuracy and computational performance resulting by refactoring and reengineering parts of the code are discussed. Issues in refactoring that are specific to the domain of physics simulation are identified and their impact is elucidated. Preliminary quantitative results are reported.

  15. Assessment of Geant4 Prompt-Gamma Emission Yields in the Context of Proton Therapy Monitoring

    Science.gov (United States)

    Pinto, Marco; Dauvergne, Denis; Freud, Nicolas; Krimmer, Jochen; Létang, Jean M.; Testa, Etienne

    2016-01-01

    Monte Carlo tools have been long used to assist the research and development of solutions for proton therapy monitoring. The present work focuses on the prompt-gamma emission yields by comparing experimental data with the outcomes of the current version of Geant4 using all applicable proton inelastic models. For the case in study and using the binary cascade model, it was found that Geant4 overestimates the prompt-gamma emission yields by 40.2 ± 0.3%, even though it predicts the prompt-gamma profile length of the experimental profile accurately. In addition, the default implementations of all proton inelastic models show an overestimation in the number of prompt gammas emitted. Finally, a set of built-in options and physically sound Geant4 source code changes have been tested in order to try to improve the discrepancy observed. A satisfactory agreement was found when using the QMD model with a wave packet width equal to 1.3 fm2. PMID:26858937

  16. Microdosimetry calculations for monoenergetic electrons using Geant4-DNA combined with a weighted track sampling algorithm.

    Science.gov (United States)

    Famulari, Gabriel; Pater, Piotr; Enger, Shirin A

    2017-07-07

    The aim of this study was to calculate microdosimetric distributions for low energy electrons simulated using the Monte Carlo track structure code Geant4-DNA. Tracks for monoenergetic electrons with kinetic energies ranging from 100 eV to 1 MeV were simulated in an infinite spherical water phantom using the Geant4-DNA extension included in Geant4 toolkit version 10.2 (patch 02). The microdosimetric distributions were obtained through random sampling of transfer points and overlaying scoring volumes within the associated volume of the tracks. Relative frequency distributions of energy deposition f(>E)/f(>0) and dose mean lineal energy ([Formula: see text]) values were calculated in nanometer-sized spherical and cylindrical targets. The effects of scoring volume and scoring techniques were examined. The results were compared with published data generated using MOCA8B and KURBUC. Geant4-DNA produces a lower frequency of higher energy deposits than MOCA8B. The [Formula: see text] values calculated with Geant4-DNA are smaller than those calculated using MOCA8B and KURBUC. The differences are mainly due to the lower ionization and excitation cross sections of Geant4-DNA for low energy electrons. To a lesser extent, discrepancies can also be attributed to the implementation in this study of a new and fast scoring technique that differs from that used in previous studies. For the same mean chord length ([Formula: see text]), the [Formula: see text] calculated in cylindrical volumes are larger than those calculated in spherical volumes. The discrepancies due to cross sections and scoring geometries increase with decreasing scoring site dimensions. A new set of [Formula: see text] values has been presented for monoenergetic electrons using a fast track sampling algorithm and the most recent physics models implemented in Geant4-DNA. This dataset can be combined with primary electron spectra to predict the radiation quality of photon and electron beams.

  17. Automatic modeling for the Monte Carlo transport code Geant4

    International Nuclear Information System (INIS)

    Nie Fanzhi; Hu Liqin; Wang Guozhong; Wang Dianxi; Wu Yican; Wang Dong; Long Pengcheng; FDS Team

    2015-01-01

    Geant4 is a widely used Monte Carlo transport simulation package. Its geometry models could be described in Geometry Description Markup Language (GDML), but it is time-consuming and error-prone to describe the geometry models manually. This study implemented the conversion between computer-aided design (CAD) geometry models and GDML models. This method has been Studied based on Multi-Physics Coupling Analysis Modeling Program (MCAM). The tests, including FDS-Ⅱ model, demonstrated its accuracy and feasibility. (authors)

  18. NaI(Tl) detectors modeling in MCNP-X and Gate/Geant4 codes

    Energy Technology Data Exchange (ETDEWEB)

    Affonso, Renato Raoni Werneck; Silva, Ademir Xavier da, E-mail: raoniwa@yahoo.com.br, E-mail: ademir@nuclear.ufrj.br [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (PEN/COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear; Salgado, Cesar Marques, E-mail: otero@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    NaI (Tl) detectors are widely used in gamma-ray densitometry, but their modeling in Monte Carlo codes, such as MCNP-X and Gate/Geant4, needs a lot of work and does not yield comparable results with experimental arrangements, possibly due to non-simulated physical phenomena, such as light transport within the scintillator. Therefore, it is necessary a methodology that positively impacts the results of the simulations while maintaining the real dimensions of the detectors and other objects to allow validating a modeling that matches up with the experimental arrangement. Thus, the objective of this paper is to present the studies conducted with the MCNPX and Gate/Geant4 codes, in which the comparisons of their results were satisfactory, showing that both can be used for the same purposes. (author)

  19. Simulation of Auger electron emission from nanometer-size gold targets using the Geant4 Monte Carlo simulation toolkit

    Energy Technology Data Exchange (ETDEWEB)

    Incerti, S., E-mail: sebastien.incerti@tdt.edu.vn [Division of Nuclear Physics, Ton Duc Thang University, Tan Phong Ward, District 7, Ho Chi Minh City (Viet Nam); Faculty of Applied Sciences, Ton Duc Thang University, Tan Phong Ward, District 7, Ho Chi Minh City (Viet Nam); Univ. Bordeaux, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); Suerfu, B.; Xu, J. [Department of Physics, Princeton University, Princeton, NJ (United States); Ivantchenko, V. [Ecoanalytica, Moscow (Russian Federation); Geant4 Associates International Ltd, Hebden Bridge (United Kingdom); Mantero, A. [SWHARD srl, via Greto di Cornigliano 6r, 16152 Genova (Italy); Brown, J.M.C. [School of Mathematics and Physics, Queen’s University Belfast, Belfast, Northern Ireland (United Kingdom); Bernal, M.A. [Instituto de Física Gleb Wataghin, Universidade Estadual de Campinas, SP (Brazil); Francis, Z. [Université Saint Joseph, Faculty of Sciences, Department of Physics, Beirut (Lebanon); Karamitros, M. [Notre Dame Radiation Laboratory, University of Notre Dame, Notre Dame, IN (United States); Tran, H.N. [Division of Nuclear Physics, Ton Duc Thang University, Tan Phong Ward, District 7, Ho Chi Minh City (Viet Nam); Faculty of Applied Sciences, Ton Duc Thang University, Tan Phong Ward, District 7, Ho Chi Minh City (Viet Nam)

    2016-04-01

    A revised atomic deexcitation framework for the Geant4 general purpose Monte Carlo toolkit capable of simulating full Auger deexcitation cascades was implemented in June 2015 release (version 10.2 Beta). An overview of this refined framework and testing of its capabilities is presented for the irradiation of gold nanoparticles (NP) with keV photon and MeV proton beams. The resultant energy spectra of secondary particles created within and that escape the NP are analyzed and discussed. It is anticipated that this new functionality will improve and increase the use of Geant4 in the medical physics, radiobiology, nanomedicine research and other low energy physics fields.

  20. Comparison of electromagnetic and hadronic models generated using Geant 4 with antiproton dose measured in CERN.

    Science.gov (United States)

    Tavakoli, Mohammad Bagher; Reiazi, Reza; Mohammadi, Mohammad Mehdi; Jabbari, Keyvan

    2015-01-01

    After proposing the idea of antiproton cancer treatment in 1984 many experiments were launched to investigate different aspects of physical and radiobiological properties of antiproton, which came from its annihilation reactions. One of these experiments has been done at the European Organization for Nuclear Research known as CERN using the antiproton decelerator. The ultimate goal of this experiment was to assess the dosimetric and radiobiological properties of beams of antiprotons in order to estimate the suitability of antiprotons for radiotherapy. One difficulty on this way was the unavailability of antiproton beam in CERN for a long time, so the verification of Monte Carlo codes to simulate antiproton depth dose could be useful. Among available simulation codes, Geant4 provides acceptable flexibility and extensibility, which progressively lead to the development of novel Geant4 applications in research domains, especially modeling the biological effects of ionizing radiation at the sub-cellular scale. In this study, the depth dose corresponding to CERN antiproton beam energy by Geant4 recruiting all the standard physics lists currently available and benchmarked for other use cases were calculated. Overall, none of the standard physics lists was able to draw the antiproton percentage depth dose. Although, with some models our results were promising, the Bragg peak level remained as the point of concern for our study. It is concluded that the Bertini model with high precision neutron tracking (QGSP_BERT_HP) is the best to match the experimental data though it is also the slowest model to simulate events among the physics lists.

  1. Geant4 and Fano cavity test: where are we?

    CERN Document Server

    Elles, S; Maire, M; Urbàn, L

    2008-01-01

    The electron transport algorithm implemented in Geant4 has been recently revised. The modifications concern several physics aspects of the simulation model: the step limitation, the energy loss along a step and the multiple scattering. The Fano cavity setup was used to test these developments. The upgrades increase significantly the accuracy of the electron transport simulation. The ratio of simulated to theoretical dose deposition in the cavity is stable to ~1% while varying several parameters and within ~1.5% of the expected value for water and graphite. Work is underway to identify and resolve the remaining shift.

  2. Monte Carlo application based on GEANT4 toolkit to simulate a laser–plasma electron beam line for radiobiological studies

    Energy Technology Data Exchange (ETDEWEB)

    Lamia, D., E-mail: debora.lamia@ibfm.cnr.it [Institute of Molecular Bioimaging and Physiology IBFM CNR – LATO, Cefalù (Italy); Russo, G., E-mail: giorgio.russo@ibfm.cnr.it [Institute of Molecular Bioimaging and Physiology IBFM CNR – LATO, Cefalù (Italy); Casarino, C.; Gagliano, L.; Candiano, G.C. [Institute of Molecular Bioimaging and Physiology IBFM CNR – LATO, Cefalù (Italy); Labate, L. [Intense Laser Irradiation Laboratory (ILIL) – National Institute of Optics INO CNR, Pisa (Italy); National Institute for Nuclear Physics INFN, Pisa Section and Frascati National Laboratories LNF (Italy); Baffigi, F.; Fulgentini, L.; Giulietti, A.; Koester, P.; Palla, D. [Intense Laser Irradiation Laboratory (ILIL) – National Institute of Optics INO CNR, Pisa (Italy); Gizzi, L.A. [Intense Laser Irradiation Laboratory (ILIL) – National Institute of Optics INO CNR, Pisa (Italy); National Institute for Nuclear Physics INFN, Pisa Section and Frascati National Laboratories LNF (Italy); Gilardi, M.C. [Institute of Molecular Bioimaging and Physiology IBFM CNR, Segrate (Italy); University of Milano-Bicocca, Milano (Italy)

    2015-06-21

    We report on the development of a Monte Carlo application, based on the GEANT4 toolkit, for the characterization and optimization of electron beams for clinical applications produced by a laser-driven plasma source. The GEANT4 application is conceived so as to represent in the most general way the physical and geometrical features of a typical laser-driven accelerator. It is designed to provide standard dosimetric figures such as percentage dose depth curves, two-dimensional dose distributions and 3D dose profiles at different positions both inside and outside the interaction chamber. The application was validated by comparing its predictions to experimental measurements carried out on a real laser-driven accelerator. The work is aimed at optimizing the source, by using this novel application, for radiobiological studies and, in perspective, for medical applications. - Highlights: • Development of a Monte Carlo application based on GEANT4 toolkit. • Experimental measurements carried out with a laser-driven acceleration system. • Validation of Geant4 application comparing experimental data with the simulated ones. • Dosimetric characterization of the acceleration system.

  3. The generation of absorbed dose profiles of proton beam in water using Geant4 code

    International Nuclear Information System (INIS)

    Christovao, Marilia T.; Campos, Tarcisio Passos R. de

    2007-01-01

    The present article approaches simulations on the proton beam radiation therapy, using an application based on the code GEANT4, with Open GL as a visualization drive and JAS3 (Java Analysis Studio) analysis data tools systems, implementing the AIDA interfaces. The proton radiotherapy is adapted to treat cancer or other benign tumors that are close to sensitive structures, since it allows precise irradiation of the target with high doses, while the health tissues adjacent to vital organs and tissues are preserved, due to physical property of dose profile. GEANT4 is a toolkit for simulating the transport of particles through matter, in complex geometries. Taking advantage of the object-oriented project features, the user can adapt or extend the tool in all domain, due to the flexibility of the code, providing a subroutine's group for materials definition, geometries and particles properties in agreement with the user's needs to generate the Monte Carlo simulation. In this paper, the parameters of beam line used in the simulation possess adjustment elements, such as: the range shifter, composition and dimension; the beam line, energy, intensity, length, according with physic processes applied. The simulation result is the depth dose profiles on water, dependent on the various incident beam energy. Starting from those profiles, one can define appropriate conditions for proton radiotherapy in ocular region. (author)

  4. R and D on co-working transport schemes in Geant4

    Energy Technology Data Exchange (ETDEWEB)

    Pia, M G; Saracco, P; Sudhakar, M [INFN Sezione di Genova, Via Dodecaneso 33, 16146 Genova (Italy); Zoglauer, A [University of California at Berkeley, Berkeley, CA 94720-7450 (United States); Augelli, M [CNES, 18 Av. Edouard Belin, 31401 Toulouse (France); Gargioni, E [University Medical Center Hamburg-Eppendorf, D-20246 Hamburg (Germany); Kim, C H [Hanyang University, 17 Haengdang-dong, Seongdong-gu, Seoul, 133-791 (Korea, Republic of); Quintieri, L [INFN Laboratori Nazionali di Frascati, Via Enrico Fermi 40, I-00044 Frascati (Italy); Filho, P P de Queiroz; Santos, D de Souza [IRD, Av. Salvador Allende, s/n. 22780-160, Rio de Janeiro, RJ (Brazil); Weidenspointner, G [MPI Halbleiterlabor, Otto-Hahn-Ring 6, D-81739 Muenchen (Germany); Begalli, M, E-mail: mariagrazia.pia@ge.infn.i [UERJ, R. Sao Francisco Xavier, 524. 20550-013, Rio de Janeiro, RJ (Brazil)

    2010-04-01

    A research and development (R and D) project related to the extension of the Geant4 toolkit has been recently launched to address fundamental methods in radiation transport simulation. The project focuses on simulation at different scales in the same experimental environment; this problem requires new methods across the current boundaries of condensed-random-walk and discrete transport schemes. The new developments have been motivated by experimental requirements in various domains, including nanodosimetry, astronomy and detector developments for high energy physics applications.

  5. Assessment of Geant4 Maintainability with respect to software engineering references

    Science.gov (United States)

    Ronchieri, Elisabetta; Grazia Pia, Maria; Canaparo, Marco

    2017-10-01

    Over time computer scientists have been provided metrics to measure software maintainability. In existing literature, a large number of references can be found about this topic; nevertheless, a lack of quantitative assessment of maintainability metrics has been observed. In this paper, we summarize the challenges of adopting code measurements in the context of physics software system. In this pilot study, we have used Geant4 - a twenty-year-old software system - to conduct this research and set the grounds for further discussion.

  6. Software aspects of the Geant4 validation repository

    Science.gov (United States)

    Dotti, Andrea; Wenzel, Hans; Elvira, Daniel; Genser, Krzysztof; Yarba, Julia; Carminati, Federico; Folger, Gunter; Konstantinov, Dmitri; Pokorski, Witold; Ribon, Alberto

    2017-10-01

    The Geant4, GeantV and GENIE collaborations regularly perform validation and regression tests for simulation results. DoSSiER (Database of Scientific Simulation and Experimental Results) is being developed as a central repository to store the simulation results as well as the experimental data used for validation. DoSSiER is easily accessible via a web application. In addition, a web service allows for programmatic access to the repository to extract records in JSON or XML exchange formats. In this article, we describe the functionality and the current status of various components of DoSSiER as well as the technology choices we made.

  7. Software Aspects of the Geant4 Validation Repository

    CERN Document Server

    Dotti, Andrea; Elvira, Daniel; Genser, Krzysztof; Yarba, Julia; Carminati, Federico; Folger, Gunter; Konstantinov, Dmitri; Pokorski, Witold; Ribon, Alberto

    2016-01-01

    The Geant4, GeantV and GENIE collaborations regularly perform validation and regression tests for simulation results. DoSSiER (Database of Scientic Simulation and Experimental Results) is being developed as a central repository to store the simulation results as well as the experimental data used for validation. DoSSiER is easily accessible via a web application. In addition, a web service allows for programmatic access to the repository to extract records in JSON or XML exchange formats. In this article, we describe the functionality and the current status of various components of DoSSiER as well as the technology choices we made.

  8. Automatic modeling for the Monte Carlo transport code Geant4 in MCAM

    International Nuclear Information System (INIS)

    Nie Fanzhi; Hu Liqin; Wang Guozhong; Wang Dianxi; Wu Yican; Wang Dong; Long Pengcheng; FDS Team

    2014-01-01

    Geant4 is a widely used Monte Carlo transport simulation package. Its geometry models could be described in geometry description markup language (GDML), but it is time-consuming and error-prone to describe the geometry models manually. This study implemented the conversion between computer-aided design (CAD) geometry models and GDML models. The conversion program was integrated into Multi-Physics Coupling Analysis Modeling Program (MCAM). The tests, including FDS-Ⅱ model, demonstrated its accuracy and feasibility. (authors)

  9. Diffusion-controlled reactions modeling in Geant4-DNA

    Energy Technology Data Exchange (ETDEWEB)

    Karamitros, M., E-mail: matkara@gmail.com [CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, INCIA, UMR 5287, F-33400 Talence (France); Luan, S. [University of New Mexico, Department of Computer Science, Albuquerque, NM (United States); Bernal, M.A. [Instituto de Física Gleb Wataghin, Universidade Estadual de Campinas, SP (Brazil); Allison, J. [Geant4 Associates International Ltd (United Kingdom); Baldacchino, G. [CEA Saclay, IRAMIS, LIDYL, Radiation Physical Chemistry Group, F-91191 Gif sur Yvette Cedex (France); CNRS, UMR3299, SIS2M, F-91191 Gif sur Yvette Cedex (France); Davidkova, M. [Nuclear Physics Institute of the ASCR, Prague (Czech Republic); Francis, Z. [Saint Joseph University, Faculty of Sciences, Department of Physics, Mkalles, Beirut (Lebanon); Friedland, W. [Helmholtz Zentrum München, German Research Center for Environmental Health, Institute of Radiation Protection, Ingolstädter Landstr. 1, 85764 Neuherberg (Germany); Ivantchenko, V. [Ecoanalytica, 119899 Moscow (Russian Federation); Geant4 Associates International Ltd (United Kingdom); Ivantchenko, A. [Geant4 Associates International Ltd (United Kingdom); Mantero, A. [SwHaRD s.r.l., via Buccari 9, 16153 Genova (Italy); Nieminem, P.; Santin, G. [ESA-ESTEC, 2200 AG Noordwijk (Netherlands); Tran, H.N. [Division of Nuclear Physics and Faculty of Applied Sciences, Ton Duc Thang University, Tan Phong Ward, District 7, Ho Chi Minh City (Viet Nam); Stepan, V. [CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); Nuclear Physics Institute of the ASCR, Prague (Czech Republic); Incerti, S., E-mail: incerti@cenbg.in2p3.fr [CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France)

    2014-10-01

    Context Under irradiation, a biological system undergoes a cascade of chemical reactions that can lead to an alteration of its normal operation. There are different types of radiation and many competing reactions. As a result the kinetics of chemical species is extremely complex. The simulation becomes then a powerful tool which, by describing the basic principles of chemical reactions, can reveal the dynamics of the macroscopic system. To understand the dynamics of biological systems under radiation, since the 80s there have been on-going efforts carried out by several research groups to establish a mechanistic model that consists in describing all the physical, chemical and biological phenomena following the irradiation of single cells. This approach is generally divided into a succession of stages that follow each other in time: (1) the physical stage, where the ionizing particles interact directly with the biological material; (2) the physico-chemical stage, where the targeted molecules release their energy by dissociating, creating new chemical species; (3) the chemical stage, where the new chemical species interact with each other or with the biomolecules; (4) the biological stage, where the repairing mechanisms of the cell come into play. This article focuses on the modeling of the chemical stage. Method This article presents a general method of speeding-up chemical reaction simulations in fluids based on the Smoluchowski equation and Monte-Carlo methods, where all molecules are explicitly simulated and the solvent is treated as a continuum. The model describes diffusion-controlled reactions. This method has been implemented in Geant4-DNA. The keys to the new algorithm include: (1) the combination of a method to compute time steps dynamically with a Brownian bridge process to account for chemical reactions, which avoids costly fixed time step simulations; (2) a k–d tree data structure for quickly locating, for a given molecule, its closest reactants. The

  10. CAD-based automatic modeling method for Geant4 geometry model through MCAM

    International Nuclear Information System (INIS)

    Wang, D.; Nie, F.; Wang, G.; Long, P.; LV, Z.

    2013-01-01

    The full text of publication follows. Geant4 is a widely used Monte Carlo transport simulation package. Before calculating using Geant4, the calculation model need be established which could be described by using Geometry Description Markup Language (GDML) or C++ language. However, it is time-consuming and error-prone to manually describe the models by GDML. Automatic modeling methods have been developed recently, but there are some problems that exist in most present modeling programs, specially some of them were not accurate or adapted to specifically CAD format. To convert the GDML format models to CAD format accurately, a Geant4 Computer Aided Design (CAD) based modeling method was developed for automatically converting complex CAD geometry model into GDML geometry model. The essence of this method was dealing with CAD model represented with boundary representation (B-REP) and GDML model represented with constructive solid geometry (CSG). At first, CAD model was decomposed to several simple solids which had only one close shell. And then the simple solid was decomposed to convex shell set. Then corresponding GDML convex basic solids were generated by the boundary surfaces getting from the topological characteristic of a convex shell. After the generation of these solids, GDML model was accomplished with series boolean operations. This method was adopted in CAD/Image-based Automatic Modeling Program for Neutronics and Radiation Transport (MCAM), and tested with several models including the examples in Geant4 install package. The results showed that this method could convert standard CAD model accurately, and can be used for Geant4 automatic modeling. (authors)

  11. The study on the import of the geometric body by GDML in GEANT4

    International Nuclear Information System (INIS)

    Sun Baodong; Liu Huilan; Sun Dawang; Xie Zhaoyang; Song Yushou

    2014-01-01

    Geometry Description Markup Language (GDML) can be used as an application interface program to import the geometric body into GEANT4. It greatly simplifies the detector construction work with high reliability. With this mechanism the geometric data of a detector is described in an XML file and read by the XML parser embedded in GEANT4. The geometric structure of a detector is designed in CAD toolkit Solidworks and saved as a standard STEP file. Then, by FastRad the STEP file is transformed into XML script, which is readable for GEANT4. In comparison with the detectors constructed by Constructed Solid Geometry (CSG) provided by GEANT4, those imported by GDML also satisfies the requests of general simulation application. At the same time, some solutions and tips for several common problems during the progress constructing the detectors by GDML are given. (authors)

  12. GGEMS-Brachy: GPU GEant4-based Monte Carlo simulation for brachytherapy applications

    Science.gov (United States)

    Lemaréchal, Yannick; Bert, Julien; Falconnet, Claire; Després, Philippe; Valeri, Antoine; Schick, Ulrike; Pradier, Olivier; Garcia, Marie-Paule; Boussion, Nicolas; Visvikis, Dimitris

    2015-07-01

    In brachytherapy, plans are routinely calculated using the AAPM TG43 formalism which considers the patient as a simple water object. An accurate modeling of the physical processes considering patient heterogeneity using Monte Carlo simulation (MCS) methods is currently too time-consuming and computationally demanding to be routinely used. In this work we implemented and evaluated an accurate and fast MCS on Graphics Processing Units (GPU) for brachytherapy low dose rate (LDR) applications. A previously proposed Geant4 based MCS framework implemented on GPU (GGEMS) was extended to include a hybrid GPU navigator, allowing navigation within voxelized patient specific images and analytically modeled 125I seeds used in LDR brachytherapy. In addition, dose scoring based on track length estimator including uncertainty calculations was incorporated. The implemented GGEMS-brachy platform was validated using a comparison with Geant4 simulations and reference datasets. Finally, a comparative dosimetry study based on the current clinical standard (TG43) and the proposed platform was performed on twelve prostate cancer patients undergoing LDR brachytherapy. Considering patient 3D CT volumes of 400  × 250  × 65 voxels and an average of 58 implanted seeds, the mean patient dosimetry study run time for a 2% dose uncertainty was 9.35 s (≈500 ms 10-6 simulated particles) and 2.5 s when using one and four GPUs, respectively. The performance of the proposed GGEMS-brachy platform allows envisaging the use of Monte Carlo simulation based dosimetry studies in brachytherapy compatible with clinical practice. Although the proposed platform was evaluated for prostate cancer, it is equally applicable to other LDR brachytherapy clinical applications. Future extensions will allow its application in high dose rate brachytherapy applications.

  13. GGEMS-Brachy: GPU GEant4-based Monte Carlo simulation for brachytherapy applications

    International Nuclear Information System (INIS)

    Lemaréchal, Yannick; Bert, Julien; Schick, Ulrike; Pradier, Olivier; Garcia, Marie-Paule; Boussion, Nicolas; Visvikis, Dimitris; Falconnet, Claire; Després, Philippe; Valeri, Antoine

    2015-01-01

    In brachytherapy, plans are routinely calculated using the AAPM TG43 formalism which considers the patient as a simple water object. An accurate modeling of the physical processes considering patient heterogeneity using Monte Carlo simulation (MCS) methods is currently too time-consuming and computationally demanding to be routinely used. In this work we implemented and evaluated an accurate and fast MCS on Graphics Processing Units (GPU) for brachytherapy low dose rate (LDR) applications. A previously proposed Geant4 based MCS framework implemented on GPU (GGEMS) was extended to include a hybrid GPU navigator, allowing navigation within voxelized patient specific images and analytically modeled 125 I seeds used in LDR brachytherapy. In addition, dose scoring based on track length estimator including uncertainty calculations was incorporated. The implemented GGEMS-brachy platform was validated using a comparison with Geant4 simulations and reference datasets. Finally, a comparative dosimetry study based on the current clinical standard (TG43) and the proposed platform was performed on twelve prostate cancer patients undergoing LDR brachytherapy. Considering patient 3D CT volumes of 400  × 250  × 65 voxels and an average of 58 implanted seeds, the mean patient dosimetry study run time for a 2% dose uncertainty was 9.35 s (≈500 ms 10 −6 simulated particles) and 2.5 s when using one and four GPUs, respectively. The performance of the proposed GGEMS-brachy platform allows envisaging the use of Monte Carlo simulation based dosimetry studies in brachytherapy compatible with clinical practice. Although the proposed platform was evaluated for prostate cancer, it is equally applicable to other LDR brachytherapy clinical applications. Future extensions will allow its application in high dose rate brachytherapy applications. (paper)

  14. Modeling of a cyclotron target for the production of 11C with Geant4.

    Science.gov (United States)

    Chiappiniello, Andrea; Zagni, Federico; Infantino, Angelo; Vichi, Sara; Cicoria, Gianfranco; Morigi, Maria Pia; Marengo, Mario

    2018-04-12

    In medical cyclotron facilities, 11C is produced according to the 14N(p,α)11C reaction and widely employed in studies of prostate and brain cancers by Positron Emission Tomography. It is known from literature [1] that the 11C-target assembly shows a reduction in efficiency during time, meaning a decrease of activity produced at the end of bombardment. This effect might depend on aspects still not completely known. Possible causes of the loss of performance of the 11C-target assembly were addressed by Monte Carlo simulations. Geant4 was used to model the 11C-target assembly of a GE PETtrace cyclotron. The physical and transport parameters to be used in the energy range of medical applications were extracted from literature data and 11C routine productions. The Monte Carlo assessment of 11C saturation yield was performed varying several parameters such as the proton energy and the angle of the target assembly with respect to the proton beam. The estimated 11C saturation yield is in agreement with IAEA data at the energy of interest, while is about the 35% greater than experimental value. A more comprehensive modeling of the target system, including thermodynamic effect, is required. The energy absorbed in the inner layer of the target chamber was up to 46.5 J/mm2 under typical irradiation conditions. This study shows that Geant4 is potentially a useful tool to design and optimize targetry for PET radionuclide productions. Tests to choose the Geant4 physics libraries should be performed before using this tool with different energies and materials. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  15. Geant4 simulation of the response of phosphor screens for X-ray imaging

    International Nuclear Information System (INIS)

    Pistrui-Maximean, S.A.; Freud, N.; Letang, J.M.; Koch, A.; Munier, B.; Walenta, A.H.; Montarou, G.; Babot, D.

    2006-01-01

    In order to predict and optimize the response of phosphor screens, it is important to understand the role played by the different physical processes inside the scintillator layer. A simulation model based on the Monte Carlo code Geant4 was developed to determine the Modulation Transfer Function (MTF) of phosphor screens for energies used in X-ray medical imaging and nondestructive testing applications. The visualization of the dose distribution inside the phosphor layer gives an insight into how the MTF is progressively degraded by X-ray and electron transport. The simulation model allows to study the influence of physical and technological parameters on the detector performances, as well as to design and optimize new detector configurations. Preliminary MTF measurements have been carried out and agreement with experimental data has been found in the case of a commercial screen (Kodak Lanex Fine) at an X-ray tube potential of 100 kV. Further validation with other screens (transparent or granular) at different energies is under way

  16. Geant4 simulation of the response of phosphor screens for X-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Pistrui-Maximean, S.A. [Laboratory of Nondestructive Testing using Ionizing Radiation, INSA-Lyon Scientific and Technical University, Bat. Antoine de Saint Exupery, 69621 Villeurbanne Cedex (France)]. E-mail: simona.pistrui@insa-lyon.fr; Freud, N. [Laboratory of Nondestructive Testing using Ionizing Radiation, INSA-Lyon Scientific and Technical University, Bat. Antoine de Saint Exupery, 69621 Villeurbanne Cedex (France); Letang, J.M. [Laboratory of Nondestructive Testing using Ionizing Radiation, INSA-Lyon Scientific and Technical University, Bat. Antoine de Saint Exupery, 69621 Villeurbanne Cedex (France); Koch, A. [Thales Electron Devices, 38430 Moirans (France); Munier, B. [Thales Electron Devices, 38430 Moirans (France); Walenta, A.H. [Department of Detectors and Electronics, FB Physik, University of Siegen, 57068 Siegen (Germany); Montarou, G. [Corpuscular Physics Laboratory, Blaise Pascal University, 63177 Aubiere Cedex (France); Babot, D. [Laboratory of Nondestructive Testing using Ionizing Radiation, INSA-Lyon Scientific and Technical University, Bat. Antoine de Saint Exupery, 69621 Villeurbanne Cedex (France)

    2006-07-01

    In order to predict and optimize the response of phosphor screens, it is important to understand the role played by the different physical processes inside the scintillator layer. A simulation model based on the Monte Carlo code Geant4 was developed to determine the Modulation Transfer Function (MTF) of phosphor screens for energies used in X-ray medical imaging and nondestructive testing applications. The visualization of the dose distribution inside the phosphor layer gives an insight into how the MTF is progressively degraded by X-ray and electron transport. The simulation model allows to study the influence of physical and technological parameters on the detector performances, as well as to design and optimize new detector configurations. Preliminary MTF measurements have been carried out and agreement with experimental data has been found in the case of a commercial screen (Kodak Lanex Fine) at an X-ray tube potential of 100 kV. Further validation with other screens (transparent or granular) at different energies is under way.

  17. Monte Carlo simulation of the electron transport through thin slabs: A comparative study of PENELOPE, GEANT3, GEANT4, EGSnrc and MCNPX

    Energy Technology Data Exchange (ETDEWEB)

    Vilches, M. [Servicio de Fisica y Proteccion Radiologica, Hospital Regional Universitario ' Virgen de las Nieves' , Avda. de las Fuerzas Armadas, 2, E-18014 Granada (Spain)]. E-mail: mvilches@ugr.es; Garcia-Pareja, S. [Servicio de Radiofisica Hospitalaria, Hospital Regional Universitario ' Carlos Haya' , Avda. Carlos Haya, s/n, E-29010 Malaga (Spain)]. E-mail: garciapareja@gmail.com; Guerrero, R. [Servicio de Radiofisica, Hospital Universitario ' San Cecilio' , Avda. Dr. Oloriz, 16, E-18012 Granada (Spain)]. E-mail: rafael.guerrero.alcalde.sspa@juntadeandalucia.es; Anguiano, M. [Departamento de Fisica Atomica, Molecular y Nuclear, Universidad de Granada, E-18071 Granada (Spain)]. E-mail: mangui@ugr.es; Lallena, A.M. [Departamento de Fisica Atomica, Molecular y Nuclear, Universidad de Granada, E-18071 Granada (Spain)]. E-mail: lallena@ugr.es

    2007-01-15

    The Monte Carlo simulation of the electron transport through thin slabs is studied with five general purpose codes: PENELOPE, GEANT3, GEANT4, EGSnrc and MCNPX. The different material foils analyzed in the old experiments of Kulchitsky and Latyshev [L.A. Kulchitsky, G.D. Latyshev, Phys. Rev. 61 (1942) 254] and Hanson et al. [A.O. Hanson, L.H. Lanzl, E.M. Lyman, M.B. Scott, Phys. Rev. 84 (1951) 634] are used to perform the comparison between the Monte Carlo codes. Non-negligible differences are observed in the angular distributions of the transmitted electrons obtained with the some of the codes. The experimental data are reasonably well described by EGSnrc, PENELOPE (v.2005) and GEANT4. A general good agreement is found for EGSnrc and PENELOPE (v.2005) in all the cases analyzed.

  18. Monte Carlo simulation of the electron transport through thin slabs: A comparative study of PENELOPE, GEANT3, GEANT4, EGSnrc and MCNPX

    International Nuclear Information System (INIS)

    Vilches, M.; Garcia-Pareja, S.; Guerrero, R.; Anguiano, M.; Lallena, A.M.

    2007-01-01

    The Monte Carlo simulation of the electron transport through thin slabs is studied with five general purpose codes: PENELOPE, GEANT3, GEANT4, EGSnrc and MCNPX. The different material foils analyzed in the old experiments of Kulchitsky and Latyshev [L.A. Kulchitsky, G.D. Latyshev, Phys. Rev. 61 (1942) 254] and Hanson et al. [A.O. Hanson, L.H. Lanzl, E.M. Lyman, M.B. Scott, Phys. Rev. 84 (1951) 634] are used to perform the comparison between the Monte Carlo codes. Non-negligible differences are observed in the angular distributions of the transmitted electrons obtained with the some of the codes. The experimental data are reasonably well described by EGSnrc, PENELOPE (v.2005) and GEANT4. A general good agreement is found for EGSnrc and PENELOPE (v.2005) in all the cases analyzed

  19. Use of GEANT4 vs. MCNPX for the characterization of a boron-lined neutron detector

    Energy Technology Data Exchange (ETDEWEB)

    Ende, B.M. van der; Atanackovic, J.; Erlandson, A.; Bentoumi, G.

    2016-06-01

    This work compares GEANT4 with MCNPX in the characterization of a boron-lined neutron detector. The neutron energy ranges simulated in this work (0.025 eV to 20 MeV) are the traditional domain of MCNP simulations. This paper addresses the question, how well can GEANT4 and MCNPX be employed for detailed thermal neutron detector characterization? To answer this, GEANT4 and MCNPX have been employed to simulate detector response to a {sup 252}Cf energy spectrum point source, as well as to simulate mono-energetic parallel beam source geometries. The {sup 252}Cf energy spectrum simulation results demonstrate agreement in detector count rate within 3% between the two packages, with the MCNPX results being generally closer to experiment than are those from GEANT4. The mono-energetic source simulations demonstrate agreement in detector response within 5% between the two packages for all neutron energies, and within 1% for neutron energies between 100 eV and 5 MeV. Cross-checks between the two types of simulations using ISO-8529 {sup 252}Cf energy bins demonstrates that MCNPX results are more self-consistent than are GEANT4 results, by 3–4%.

  20. Geant4 simulations on Compton scattering of laser photons on relativistic electrons

    Energy Technology Data Exchange (ETDEWEB)

    Filipescu, D. [Extreme Light Infrastructure - Nuclear Physics, str. Atomistilor nr. 407, Bucharest-Magurele, P.O.BOX MG6, Romania and National Institute for Physics and Nuclear Engineering Horia Hulubei, str. Atomistilor nr. 407 (Romania); Utsunomiya, H. [Department of Physics, Konan University, Okamoto 8-9-1, Higashinada, Kobe 658-8501 (Japan); Gheorghe, I.; Glodariu, T. [National Institute for Physics and Nuclear Engineering Horia Hulubei, str. Atomistilor nr. 407 (Romania); Tesileanu, O. [Extreme Light Infrastructure - Nuclear Physics, str. Atomistilor nr. 407, Bucharest-Magurele, P.O.BOX MG6 (Romania); Shima, T.; Takahisa, K. [Research Center for Nuclear Physics, Osaka University, Suita, Osaka 567-0047 (Japan); Miyamoto, S. [Laboratory of Advanced Science and Technology for Industry, University of Hyogo, 3-1-2 Kouto, Kamigori, Hyogo 678-1205 (Japan)

    2015-02-24

    Using Geant4, a complex simulation code of the interaction between laser photons and relativistic electrons was developed. We implemented physically constrained electron beam emittance and spacial distribution parameters and we also considered a Gaussian laser beam. The code was tested against experimental data produced at the γ-ray beam line GACKO (Gamma Collaboration Hutch of Konan University) of the synchrotron radiation facility NewSUBARU. Here we will discuss the implications of transverse missallignments of the collimation system relative to the electron beam axis.

  1. Setup of HDRK-Man voxel model in Geant4 Monte Carlo code

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Jong Hwi; Cho, Sung Koo; Kim, Chan Hyeong [Hanyang Univ., Seoul (Korea, Republic of); Choi, Sang Hyoun [Inha Univ., Incheon (Korea, Republic of); Cho, Kun Woo [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2008-10-15

    Many different voxel models, developed using tomographic images of human body, are used in various fields including both ionizing and non-ionizing radiation fields. Recently a high-quality voxel model/ named HDRK-Man, was constructed at Hanyang University and used to calculate the dose conversion coefficients (DCC) values for external photon and neutron beams using the MCNPX Monte Carlo code. The objective of the present study is to set up the HDRK-Man model in Geant4 in order to use it in more advanced calculations such as 4-D Monte Carlo simulations and space dosimetry studies involving very high energy particles. To that end, the HDRK-Man was ported to Geant4 and used to calculate the DCC values for external photon beams. The calculated values were then compared with the results of the MCNPX code. In addition, a computational Linux cluster was built to improve the computing speed in Geant4.

  2. An algorithm for computing screened Coulomb scattering in GEANT4

    Energy Technology Data Exchange (ETDEWEB)

    Mendenhall, Marcus H. [Vanderbilt University Free Electron Laser Center, P.O. Box 351816 Station B, Nashville, TN 37235-1816 (United States)]. E-mail: marcus.h.mendenhall@vanderbilt.edu; Weller, Robert A. [Department of Electrical Engineering and Computer Science, Vanderbilt University, P.O. Box 351821 Station B, Nashville, TN 37235-1821 (United States)]. E-mail: robert.a.weller@vanderbilt.edu

    2005-01-01

    An algorithm has been developed for the GEANT4 Monte-Carlo package for the efficient computation of screened Coulomb interatomic scattering. It explicitly integrates the classical equations of motion for scattering events, resulting in precise tracking of both the projectile and the recoil target nucleus. The algorithm permits the user to plug in an arbitrary screening function, such as Lens-Jensen screening, which is good for backscattering calculations, or Ziegler-Biersack-Littmark screening, which is good for nuclear straggling and implantation problems. This will allow many of the applications of the TRIM and SRIM codes to be extended into the much more general GEANT4 framework where nuclear and other effects can be included.

  3. An algorithm for computing screened Coulomb scattering in GEANT4

    International Nuclear Information System (INIS)

    Mendenhall, Marcus H.; Weller, Robert A.

    2005-01-01

    An algorithm has been developed for the GEANT4 Monte-Carlo package for the efficient computation of screened Coulomb interatomic scattering. It explicitly integrates the classical equations of motion for scattering events, resulting in precise tracking of both the projectile and the recoil target nucleus. The algorithm permits the user to plug in an arbitrary screening function, such as Lens-Jensen screening, which is good for backscattering calculations, or Ziegler-Biersack-Littmark screening, which is good for nuclear straggling and implantation problems. This will allow many of the applications of the TRIM and SRIM codes to be extended into the much more general GEANT4 framework where nuclear and other effects can be included

  4. How to create an interface between UrQMD and Geant4 toolkit

    CERN Document Server

    Abdel-Waged, Khaled; Uzhinskii, V.V.

    2012-01-01

    An interface between the UrQMD-1.3cr model (version 1.3 for cosmic air showers) and the Geant4 transport toolkit has been developed. Compared to the current Geant4 (hybrid) hadronic models, this provides the ability to simulate at the microscopic level hadron, nucleus, and anti-nucleus interactions with matter from 0 to 1 TeV with a single transport code. This document provides installation requirements and instructions, as well as class and member function descriptions of the software.

  5. Preliminary assessment of Geant4 HP models and cross section libraries by reactor criticality benchmark calculations

    DEFF Research Database (Denmark)

    Cai, Xiao-Xiao; Llamas-Jansa, Isabel; Mullet, Steven

    2013-01-01

    Geant4 is an open source general purpose simulation toolkit for particle transportation in matter. Since the extension of the thermal scattering model in Geant4.9.5 and the availability of the IAEA HP model cross section libraries, it is now possible to extend the application area of Geant4......, U and O in uranium dioxide, Al metal, Be metal, and Fe metal. The native HP cross section library G4NDL does not include data for elements with atomic number larger than 92. Therefore, transuranic elements, which have impacts for a realistic reactor, can not be simulated by the combination of the HP...... models and the G4NDL library. However, cross sections of those missing isotopes were made available recently through the IAEA project “new evaluated neutron cross section libraries for Geant4”....

  6. Estimation of the dose deposited by electron beams in radiotherapy in voxelised phantoms using the Monte Carlo simulation platform GATE based on GEANT4 in a grid environment

    International Nuclear Information System (INIS)

    Perrot, Y.

    2011-01-01

    Radiation therapy treatment planning requires accurate determination of absorbed dose in the patient. Monte Carlo simulation is the most accurate method for solving the transport problem of particles in matter. This thesis is the first study dealing with the validation of the Monte Carlo simulation platform GATE (GEANT4 Application for Tomographic Emission), based on GEANT4 (Geometry And Tracking) libraries, for the computation of absorbed dose deposited by electron beams. This thesis aims at demonstrating that GATE/GEANT4 calculations are able to reach treatment planning requirements in situations where analytical algorithms are not satisfactory. The goal is to prove that GATE/GEANT4 is useful for treatment planning using electrons and competes with well validated Monte Carlo codes. This is demonstrated by the simulations with GATE/GEANT4 of realistic electron beams and electron sources used for external radiation therapy or targeted radiation therapy. The computed absorbed dose distributions are in agreement with experimental measurements and/or calculations from other Monte Carlo codes. Furthermore, guidelines are proposed to fix the physics parameters of the GATE/GEANT4 simulations in order to ensure the accuracy of absorbed dose calculations according to radiation therapy requirements. (author)

  7. Diffusion-controlled reactions modeling in Geant4-DNA

    Czech Academy of Sciences Publication Activity Database

    Karamitros, M.; Luan, S.; Bernal, M. A.; Allison, J.; Baldacchino, G.; Davídková, Marie; Francis, Z.; Friedland, W.; Ivanchenko, A.; Ivanchenko, V.; Mantero, A.; Nieminen, P.; Santin, G.; Tran, H. N.; Stepan, V.; Incerti, S.

    2014-01-01

    Roč. 274, OCT (2014), s. 841-882 ISSN 0021-9991 Institutional support: RVO:61389005 Keywords : chemical kinetics simulation * radiation chemistry * Fokker-Planck equation * Smoluchowski diffusion equation * Brownian bridge * dynamical time steps * k-d tree * radiolysis * radiobiology * Geant4-DNA * Brownian dynamics Subject RIV: BO - Biophysics Impact factor: 2.434, year: 2014

  8. Gamma-gamma density and lithology tools simulation based on GEANT4 advanced low energy Compton scattering (GALECS) package

    International Nuclear Information System (INIS)

    Esmaeili-sani, Vahid; Moussavi-zarandi, Ali; Boghrati, Behzad; Afarideh, Hossein

    2012-01-01

    Geophysical bore-hole data represent the physical properties of rocks, such as density and formation lithology, as a function of depth in a well. Properties of rocks are obtained from gamma ray transport logs. Transport of gamma rays, from a 137 Cs point gamma source situated in a bore-hole tool, through rock media to detectors, has been simulated using a GEANT4 radiation transport code. The advanced Compton scattering concepts were used to gain better analyses about well formation. The simulation and understanding of advanced Compton scattering highly depends on how accurately the effects of Doppler broadening and Rayleigh scattering are taken into account. A Monte Carlo package that simulates the gamma-gamma well logging tools based on GEANT4 advanced low energy Compton scattering (GALECS).

  9. PDB4DNA: Implementation of DNA geometry from the Protein Data Bank (PDB) description for Geant4-DNA Monte-Carlo simulations

    Science.gov (United States)

    Delage, E.; Pham, Q. T.; Karamitros, M.; Payno, H.; Stepan, V.; Incerti, S.; Maigne, L.; Perrot, Y.

    2015-07-01

    This paper describes PDB4DNA, a new Geant4 user application, based on an independent, cross-platform, free and open source C++ library, so-called PDBlib, which enables use of atomic level description of DNA molecule in Geant4 Monte Carlo particle transport simulations. For the evaluation of direct damage induced on the DNA molecule by ionizing particles, the application makes use of an algorithm able to determine the closest atom in the DNA molecule to energy depositions. Both the PDB4DNA application and the PDBlib library are available as free and open source under the Geant4 license.

  10. Towards the development of a comprehensive model of an electronic portal imaging device using Geant4

    International Nuclear Information System (INIS)

    Blake, S.; Kuncic, Z.; Vial, P.; Holloway, L.

    2010-01-01

    Full text: This work represents the first stage of an ongoing study to investigate the physical processes occurring within electronic portal imaging devices (EPlDs), including the effects of optical scattering on image quality and dosimetry. The objective of this work was to develop an initial Monte Carlo model of a linear accelerator (Iinac) beam and an EPID. The ability to simulate the radiation transport of both high energy and optical photons in a single Monte Carlo model was tested. Data from the Phase-space database for external beam radiotherapy (International Atomic Energy Agency, IAEA) was used with the Geant4 toolkit to construct a model of a Siemens Primus linac 6 MY photon source. Dose profiles and percent depth dose (PDD) curves were extracted from simulations of dose in water and compared to experimental measurements. A preliminary EPID model was developed to incorporate both high energy radiation and optical photon transport. Agreement in dose profiles inside the open beam was within 1.6%. Mean agreement in PDD curves beyond depth of dose maximum was within 6.1 % (local percent difference). The radiation transport of both high energy and optical photons were simulated and visualized in the EPID model. Further work is required to experimentally validate the EPID model. The comparison of simulated dose in water with measurements indicates that the IAEA phase-space may represent an accurate model of a linac source. We have demonstrated the feasibility of developing a comprehensive EPID model incorporating both high energy and optical physics in Geant4. (author)

  11. Performance of Geant4 in simulating semiconductor particle detector response in the energy range below 1 MeV

    Science.gov (United States)

    Soti, G.; Wauters, F.; Breitenfeldt, M.; Finlay, P.; Kraev, I. S.; Knecht, A.; Porobić, T.; Zákoucký, D.; Severijns, N.

    2013-11-01

    Geant4 simulations play a crucial role in the analysis and interpretation of experiments providing low energy precision tests of the Standard Model. This paper focuses on the accuracy of the description of the electron processes in the energy range between 100 and 1000 keV. The effect of the different simulation parameters and multiple scattering models on the backscattering coefficients is investigated. Simulations of the response of HPGe and passivated implanted planar Si detectors to β particles are compared to experimental results. An overall good agreement is found between Geant4 simulations and experimental data.

  12. Comparison of the thermal neutron scattering treatment in MCNP6 and GEANT4 codes

    Science.gov (United States)

    Tran, H. N.; Marchix, A.; Letourneau, A.; Darpentigny, J.; Menelle, A.; Ott, F.; Schwindling, J.; Chauvin, N.

    2018-06-01

    To ensure the reliability of simulation tools, verification and comparison should be made regularly. This paper describes the work performed in order to compare the neutron transport treatment in MCNP6.1 and GEANT4-10.3 in the thermal energy range. This work focuses on the thermal neutron scattering processes for several potential materials which would be involved in the neutron source designs of Compact Accelerator-based Neutrons Sources (CANS), such as beryllium metal, beryllium oxide, polyethylene, graphite, para-hydrogen, light water, heavy water, aluminium and iron. Both thermal scattering law and free gas model, coming from the evaluated data library ENDF/B-VII, were considered. It was observed that the GEANT4.10.03-patch2 version was not able to account properly the coherent elastic process occurring in crystal lattice. This bug is treated in this work and it should be included in the next release of the code. Cross section sampling and integral tests have been performed for both simulation codes showing a fair agreement between the two codes for most of the materials except for iron and aluminium.

  13. Comparison of GATE/GEANT4 with EGSnrc and MCNP for electron dose calculations at energies between 15 keV and 20 MeV.

    Science.gov (United States)

    Maigne, L; Perrot, Y; Schaart, D R; Donnarieix, D; Breton, V

    2011-02-07

    The GATE Monte Carlo simulation platform based on the GEANT4 toolkit has come into widespread use for simulating positron emission tomography (PET) and single photon emission computed tomography (SPECT) imaging devices. Here, we explore its use for calculating electron dose distributions in water. Mono-energetic electron dose point kernels and pencil beam kernels in water are calculated for different energies between 15 keV and 20 MeV by means of GATE 6.0, which makes use of the GEANT4 version 9.2 Standard Electromagnetic Physics Package. The results are compared to the well-validated codes EGSnrc and MCNP4C. It is shown that recent improvements made to the GEANT4/GATE software result in significantly better agreement with the other codes. We furthermore illustrate several issues of general interest to GATE and GEANT4 users who wish to perform accurate simulations involving electrons. Provided that the electron step size is sufficiently restricted, GATE 6.0 and EGSnrc dose point kernels are shown to agree to within less than 3% of the maximum dose between 50 keV and 4 MeV, while pencil beam kernels are found to agree to within less than 4% of the maximum dose between 15 keV and 20 MeV.

  14. Gamma-gamma density and lithology tools simulation based on GEANT4 advanced low energy Compton scattering (GALECS) package

    Energy Technology Data Exchange (ETDEWEB)

    Esmaeili-sani, Vahid, E-mail: vaheed_esmaeely80@yahoo.com [Department of Nuclear Engineering and Physics, Amirkabir University of Technology, P.O. Box 4155-4494, Tehran (Iran, Islamic Republic of); Moussavi-zarandi, Ali; Boghrati, Behzad; Afarideh, Hossein [Department of Nuclear Engineering and Physics, Amirkabir University of Technology, P.O. Box 4155-4494, Tehran (Iran, Islamic Republic of)

    2012-02-01

    Geophysical bore-hole data represent the physical properties of rocks, such as density and formation lithology, as a function of depth in a well. Properties of rocks are obtained from gamma ray transport logs. Transport of gamma rays, from a {sup 137}Cs point gamma source situated in a bore-hole tool, through rock media to detectors, has been simulated using a GEANT4 radiation transport code. The advanced Compton scattering concepts were used to gain better analyses about well formation. The simulation and understanding of advanced Compton scattering highly depends on how accurately the effects of Doppler broadening and Rayleigh scattering are taken into account. A Monte Carlo package that simulates the gamma-gamma well logging tools based on GEANT4 advanced low energy Compton scattering (GALECS).

  15. Monte-Carlo Modelling and Verification of Photoluminescence of Gd{sub 2}O{sub 3}:Eu Scintillator by Using the GEANT4 Simulation Code

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Gyu-Seok; Kim, Kum-Bae; Choi, Sang-Hyoun [Korea Institute of Radiological and Medical Science, Seoul (Korea, Republic of); Song, Yong-Keun [Inje University, Gimhae (Korea, Republic of); Lee, Soon-Sung [University of Science and Technology, Daejeon (Korea, Republic of)

    2017-01-15

    Recently, Monte Carlo methods have been used to optimize the design and modeling of radiation detectors. However, most Monte Carlo codes have a fixed and simple optical physics, and the effect of the signal readout devices is not considered because of the limitations of the geometry function. Therefore, the disadvantages of the codes prevent the modeling of the scintillator detector. The modeling of a comprehensive and extensive detector system has been reported to be feasible when the optical physics model of the GEomerty ANd Tracking 4 (GEANT 4) simulation code is used. In this study, we performed a Gd{sub 2}O{sub 3}:Eu scintillator modelling by using the GEANT4 simulation code and compared the results with the measurement data. To obtain the measurement data for the scintillator, we synthesized the Gd{sub 2}O{sub 3}:Eu scintillator by using solution combustion method and we evaluated the characteristics of the scintillator by using X-ray diffraction and photoluminescence. We imported the measured data into the GEANT4 code because GEANT4 cannot simulate a fluorescence phenomenon. The imported data were used as an energy distribution for optical photon generation based on the energy deposited in the scintillator. As a result of the simulation, a strong emission peak consistent with the measured data was observed at 611 nm, and the overall trends of the spectrum agreed with the measured data. This result is significant because the characteristics of the scintillator are equally implemented in the simulation, indicating a valuable improvement in the modeling of scintillator-based radiation detectors.

  16. The GEANT-CALOR interface

    International Nuclear Information System (INIS)

    Zeitnitz, C.; Gabriel, T.A.

    1994-01-01

    The simulation of large scale high energy physics experiments is based mainly on the GEANT package. In the current version 3.15 the simulation of hadronic interacting particles is based on GHEISHA or FLUKA. Both programs miss an accurate simulation of the interaction of low energy neutrons (E kin < 20 MeV) with the materials of the detector. The CALOR89 program package contains a low energetic neutron code. An interface between the CALOR program parts and the GEANT package has been developed

  17. A Student Project to use Geant4 Simulations for a TMS-PET combination

    International Nuclear Information System (INIS)

    Altamirano, A.; Chamorro, A.; Hurtado, K.; Romero, C.; Wahl, D.; Zamudio, A.; Rueda, A.; Solano Salinas, C. J.

    2007-01-01

    Geant4 is one of the most powerful tools for MC simulation of detectors and their applications. We present a student project to simulate a combined Transcranial Magnetic Stimulation-Positron Emission Tomography (TMS-PET) system using Geant4. This project aims to study PET-TMS systems by implementing a model for the brain response to the TMS pulse and studying the simulated PET response. In order to increase the speed of the simulations we parallelise our programs and investigate the possibility of using GRID computing

  18. A Student Project to use Geant4 Simulations for a TMS-PET combination

    Science.gov (United States)

    Altamirano, A.; Chamorro, A.; Hurtado, K.; Romero, C.; Rueda, A.; Solano Salinas, C. J.; Wahl, D.; Zamudio, A.

    2007-10-01

    Geant4 is one of the most powerful tools for MC simulation of detectors and their applications. We present a student project to simulate a combined Transcranial Magnetic Stimulation-Positron Emission Tomography (TMS-PET) system using Geant4. This project aims to study PET-TMS systems by implementing a model for the brain response to the TMS pulse and studying the simulated PET response. In order to increase the speed of the simulations we parallelise our programs and investigate the possibility of using GRID computing.

  19. Track structure modeling in liquid water: A review of the Geant4-DNA very low energy extension of the Geant4 Monte Carlo simulation toolkit

    Czech Academy of Sciences Publication Activity Database

    Bernal, M. A.; Bordage, M. C.; Brown, J. M. C.; Davídková, Marie; Delage, E.; El Bitar, Z.; Enger, S. A.; Francis, Z.; Guatelli, S.; Ivanchenko, V.; Karamitros, M.; Kyriakou, I.; Maigne, L.; Meylan, S.; Murakami, K.; Okada, S.; Payno, H.; Perrot, Y.; Petrovic, I.; Pham, Q. T.; Ristic-Fira, A.; Sasaki, T.; Štěpán, Václav; Tran, H. N.; Villagrasa, C.; Incerti, S.

    2015-01-01

    Roč. 31, č. 8 (2015), s. 861-874 ISSN 1120-1797 Institutional support: RVO:61389005 Keywords : Monte Carlo * Geant4-DNA * radiolysis * radiobiology * ionizing radiation Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 1.763, year: 2015

  20. Comparison of GEANT4 Simulations with Experimental Data for Thick Al Absorbers

    International Nuclear Information System (INIS)

    Yevseyeva, Olga; Assis, Joaquim de; Evseev, Ivan; Schelin, Hugo; Paschuk, Sergei; Milhoretto, Edney; Setti, Joao; Diaz, Katherin; Lopes, Ricardo; Hormaza, Joel

    2009-01-01

    Proton beams in medical applications deal with relatively thick targets like the human head or trunk. Therefore, relatively small differences in the total proton stopping power given, for example, by the different models provided by GEANT4 can lead to significant disagreements in the final proton energy spectra when integrated along lengthy proton trajectories. This work presents proton energy spectra obtained by GEANT4.8.2 simulations using ICRU49, Ziegler1985 and Ziegler2000 models for 19.68 MeV protons passing through a number of Al absorbers with various thicknesses. The spectra were compared with the experimental data, with TRIM/SRIM2008 and MCNPX2.4.0 simulations, and with the Payne analytical solution for the transport equation in the Fokker-Plank approximation. It is shown that the MCNPX simulations reasonably reproduce well all experimental spectra. For the relatively thin targets all the methods give practically identical results but this is not the same for the thick absorbers. It should be noted that all the spectra were measured at the proton energies significantly above 2 MeV, i.e., in the so-called 'Bethe-Bloch region'. Therefore the observed disagreements in GEANT4 results, simulated with different models, are somewhat unexpected. Further studies are necessary for better understanding and definitive conclusions.

  1. SU-E-T-531: Performance Evaluation of Multithreaded Geant4 for Proton Therapy Dose Calculations in a High Performance Computing Facility

    International Nuclear Information System (INIS)

    Shin, J; Coss, D; McMurry, J; Farr, J; Faddegon, B

    2014-01-01

    Purpose: To evaluate the efficiency of multithreaded Geant4 (Geant4-MT, version 10.0) for proton Monte Carlo dose calculations using a high performance computing facility. Methods: Geant4-MT was used to calculate 3D dose distributions in 1×1×1 mm3 voxels in a water phantom and patient's head with a 150 MeV proton beam covering approximately 5×5 cm2 in the water phantom. Three timestamps were measured on the fly to separately analyze the required time for initialization (which cannot be parallelized), processing time of individual threads, and completion time. Scalability of averaged processing time per thread was calculated as a function of thread number (1, 100, 150, and 200) for both 1M and 50 M histories. The total memory usage was recorded. Results: Simulations with 50 M histories were fastest with 100 threads, taking approximately 1.3 hours and 6 hours for the water phantom and the CT data, respectively with better than 1.0 % statistical uncertainty. The calculations show 1/N scalability in the event loops for both cases. The gains from parallel calculations started to decrease with 150 threads. The memory usage increases linearly with number of threads. No critical failures were observed during the simulations. Conclusion: Multithreading in Geant4-MT decreased simulation time in proton dose distribution calculations by a factor of 64 and 54 at a near optimal 100 threads for water phantom and patient's data respectively. Further simulations will be done to determine the efficiency at the optimal thread number. Considering the trend of computer architecture development, utilizing Geant4-MT for radiotherapy simulations is an excellent cost-effective alternative for a distributed batch queuing system. However, because the scalability depends highly on simulation details, i.e., the ratio of the processing time of one event versus waiting time to access for the shared event queue, a performance evaluation as described is recommended

  2. Absorbing CAD system geometries into GEANT

    International Nuclear Information System (INIS)

    Womersley, J.; Dragovitsch, P.; Youssef, S.

    1991-01-01

    The simulation community has for many years discussed the possibility of direct conversion of geometrical detector models from computer- aided design and engineering systems (CAD systems) to the simulation packages (which we shall assume means GEANT). This would allow fast and simultaneous optimization of the physics performance and structural integrity of detector designs. The benefit that this would offer is the avoidance of such problems as the late discovery of the rather thick cryostats in the D-Zero detector. Recent progress in the absorption of CAD geometries into GEANT models is reviewed, including descriptions of the additions to the I-DEAS solid modeller package developed for the EMPACT SSC proposal, the COGENT CAD-to-GEANT interpreter developed by Quantum Research Services, and the OCTAGON package for representing arbitrary shapes in GEANT. Likely future directions of development are described. 2 refs., 7 figs

  3. Parameterized Shower Simulation in Lelaps: a Comparison with Geant4

    International Nuclear Information System (INIS)

    Langeveld, Willy G.J.

    2003-01-01

    The detector simulation toolkit Lelaps[1] simulates electromagnetic and hadronic showers in calorimetric detector elements of high-energy particle detectors using a parameterization based on the algorithms originally developed by Grindhammer and Peters[2] and Bock et al.[3]. The primary motivations of the present paper are to verify the implementation of the parameterization, to explore regions of energy where the parameterization is valid and to serve as a basis for further improvement of the algorithm. To this end, we compared the Lelaps simulation to a detailed simulation provided by Geant4[4]. A number of different calorimeters, both electromagnetic and hadronic, were implemented in both programs. Longitudinal and radial shower profiles and their fluctuations were obtained from Geant4 over a wide energy range and compared with those obtained from Lelaps. Generally the longitudinal shower profiles are found to be in good agreement in a large part of the energy range, with poorer results at energies below about 300 MeV. Radial profiles agree well in homogeneous detectors, but are somewhat deficient in segmented ones. These deficiencies are discussed

  4. Reanimation of the RICH Test Beam Simulation in GEANT4

    CERN Document Server

    Arzymatov, Kenenbek

    2017-01-01

    This test was originally developed by Sajan Easo (LHCb) ten years ago mostly for the purpose of testing the behavior of photomultipliers, but it wasn’t used in regression testing in Gauss/Geant4 famework. The goal of project is to revive simulation of cherenkov radiaton test by completing.

  5. The GeantV project: preparing the future of simulation

    International Nuclear Information System (INIS)

    Amadio, G; Bianchini, C; Iope, R L; Apostolakis, J; Brun, R; Carminati, F; Gheata, A; Nikitina, T; Novak, M; Pokorski, W; Shadura, O; Bandieramonte, M; Bhattacharyya, A; Mohanty, A; Seghal, R; Canal, Ph; Elvira, D; Lima, G; Duhem, L; De Fine Licht, J

    2015-01-01

    Detector simulation is consuming at least half of the HEP computing cycles, and even so, experiments have to take hard decisions on what to simulate, as their needs greatly surpass the availability of computing resources. New experiments still in the design phase such as FCC, CLIC and ILC as well as upgraded versions of the existing LHC detectors will push further the simulation requirements. Since the increase in computing resources is not likely to keep pace with our needs, it is therefore necessary to explore innovative ways of speeding up simulation in order to sustain the progress of High Energy Physics. The GeantV project aims at developing a high performance detector simulation system integrating fast and full simulation that can be ported on different computing architectures, including CPU accelerators. After more than two years of R and D the project has produced a prototype capable of transporting particles in complex geometries exploiting micro-parallelism, SIMD and multithreading. Portability is obtained via C++ template techniques that allow the development of machine- independent computational kernels. A set of tables derived from Geant4 for cross sections and final states provides a realistic shower development and, having been ported into a Geant4 physics list, can be used as a basis for a direct performance comparison. (paper)

  6. NEUTRON GENERATOR FACILITY AT SFU: GEANT4 DOSE RATE PREDICTION AND VERIFICATION.

    Science.gov (United States)

    Williams, J; Chester, A; Domingo, T; Rizwan, U; Starosta, K; Voss, P

    2016-11-01

    Detailed dose rate maps for a neutron generator facility at Simon Fraser University were produced via the GEANT4 Monte Carlo framework. Predicted neutron dose rates throughout the facility were compared with radiation survey measurements made during the facility commissioning process. When accounting for thermal neutrons, the prediction and measurement agree within a factor of 2 or better in most survey locations, and within 10 % inside the vault housing the neutron generator. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. SU-E-J-72: Geant4 Simulations of Spot-Scanned Proton Beam Treatment Plans

    Energy Technology Data Exchange (ETDEWEB)

    Kanehira, T; Sutherland, K; Matsuura, T; Umegaki, K; Shirato, H [Hokkaido University, Sapporo, Hokkaido (Japan)

    2014-06-01

    Purpose: To evaluate density inhomogeneities which can effect dose distributions for real-time image gated spot-scanning proton therapy (RGPT), a dose calculation system, using treatment planning system VQA (Hitachi Ltd., Tokyo) spot position data, was developed based on Geant4. Methods: A Geant4 application was developed to simulate spot-scanned proton beams at Hokkaido University Hospital. A CT scan (0.98 × 0.98 × 1.25 mm) was performed for prostate cancer treatment with three or four inserted gold markers (diameter 1.5 mm, volume 1.77 mm3) in or near the target tumor. The CT data was read into VQA. A spot scanning plan was generated and exported to text files, specifying the beam energy and position of each spot. The text files were converted and read into our Geant4-based software. The spot position was converted into steering magnet field strength (in Tesla) for our beam nozzle. Individual protons were tracked from the vacuum chamber, through the helium chamber, steering magnets, dose monitors, etc., in a straight, horizontal line. The patient CT data was converted into materials with variable density and placed in a parametrized volume at the isocenter. Gold fiducial markers were represented in the CT data by two adjacent voxels (volume 2.38 mm3). 600,000 proton histories were tracked for each target spot. As one beam contained about 1,000 spots, approximately 600 million histories were recorded for each beam on a blade server. Two plans were considered: two beam horizontal opposed (90 and 270 degree) and three beam (0, 90 and 270 degree). Results: We are able to convert spot scanning plans from VQA and simulate them with our Geant4-based code. Our system can be used to evaluate the effect of dose reduction caused by gold markers used for RGPT. Conclusion: Our Geant4 application is able to calculate dose distributions for spot scanned proton therapy.

  8. Validation of Neutrons in Geant4 Using TARC Data - production, interaction and transportation

    CERN Document Server

    Howard, A

    2007-01-01

    The TARC (Transmutation by Adiabatic Resonance Crossing) experiment has been simulated with the Geant4 toolkit. The experiment measured neutron production from 2.5 GeV/c and 3.5 GeV/c protons incident on high purity lead. The Geant4 simulation utilised either the Bertini or Binary nuclear cascade models together with the low energy neutron HP extension. The neutron time-energy correlation and relative fluence spectrum is compared between data and simulation. A thin target comparison was undertaken for incident protons of energy 800-1600 MeV and for pre-compound evaporation and nuclear de-excitation in the energy range 24-52 MeV.

  9. The local skin dose conversion coefficients of electrons, protons and alpha particles calculated using the Geant4 code.

    Science.gov (United States)

    Zhang, Bintuan; Dang, Bingrong; Wang, Zhuanzi; Wei, Wei; Li, Wenjian

    2013-10-01

    The skin tissue-equivalent slab reported in the International Commission on Radiological Protection (ICRP) Publication 116 to calculate the localised skin dose conversion coefficients (LSDCCs) was adopted into the Monte Carlo transport code Geant4. The Geant4 code was then utilised for computation of LSDCCs due to a circular parallel beam of monoenergetic electrons, protons and alpha particles electrons and alpha particles are found to be in good agreement with the results using the MCNPX code of ICRP 116 data. The present work thus validates the LSDCC values for both electrons and alpha particles using the Geant4 code.

  10. Performance study of a cluster calculation; parallelization and application under geant4

    International Nuclear Information System (INIS)

    Trabelsi, Abir

    2007-01-01

    This work concretizes the final studies project for engineering computer sciences, it is archived within the national center of nuclear sciences and technology. The project consists in studying the performance of a set of machines in order to determine the best architecture to assemble them in a cluster. As well as the parallelism and the parallel implementation of GEANT4, as a tool of simulation. The realisation of this project consists on : 1) programming with C++ and executing the two benchmarks P MV and PMM on each station; 2) Interpreting this result in order to show the best architecture of the cluster; 3) parallelism with TOP-C the two benchmarks; 4) Executing the two Top-C versions on the cluster; 5) Generalizing this results; 6)parallelism et executing the parallel version of GEANT4. (Author). 14 refs

  11. GEANT4 simulations of the n{sub T}OF spallation source and their benchmarking

    Energy Technology Data Exchange (ETDEWEB)

    Lo Meo, S. [Research Centre ' ' Ezio Clementel' ' , ENEA, Bologna (Italy); Section of Bologna, INFN, Bologna (Italy); Cortes-Giraldo, M.A.; Lerendegui-Marco, J.; Guerrero, C.; Quesada, J.M. [Universidad de Sevilla, Facultad de Fisica, Sevilla (Spain); Massimi, C.; Vannini, G. [Section of Bologna, INFN, Bologna (Italy); University of Bologna, Physics and Astronomy Dept. ' ' Alma Mater Studiorum' ' , Bologna (Italy); Barbagallo, M.; Colonna, N. [INFN, Section of Bari, Bari (Italy); Mancusi, D. [CEA-Saclay, DEN, DM2S, SERMA, LTSD, Gif-sur-Yvette CEDEX (France); Mingrone, F. [Section of Bologna, INFN, Bologna (Italy); Sabate-Gilarte, M. [Universidad de Sevilla, Facultad de Fisica, Sevilla (Spain); European Organization for Nuclear Research (CERN), Geneva (Switzerland); Vlachoudis, V. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Collaboration: The n_TOF Collaboration

    2015-12-15

    Neutron production and transport in the spallation target of the n{sub T}OF facility at CERN has been simulated with GEANT4. The results obtained with different models of high-energy nucleon-nucleus interaction have been compared with the measured characteristics of the neutron beam, in particular the flux and its dependence on neutron energy, measured in the first experimental area. The best agreement at present, within 20% for the absolute value of the flux, and within few percent for the energy dependence in the whole energy range from thermal to 1 GeV, is obtained with the INCL++ model coupled with the GEANT4 native de-excitation model. All other available models overestimate by a larger factor, of up to 70%, the n{sub T}OF neutron flux. The simulations are also able to accurately reproduce the neutron beam energy resolution function, which is essentially determined by the moderation time inside the target/moderator assembly. The results here reported provide confidence on the use of GEANT4 for simulations of spallation neutron sources. (orig.)

  12. Modeling a gamma spectroscopy system and predicting spectra with Geant-4

    International Nuclear Information System (INIS)

    Sahin, D.; Uenlue, K.

    2009-01-01

    An activity predictor software was previously developed to foresee activities, exposure rates and gamma spectra of activated samples for Radiation Science and Engineering Center (RSEC), Penn State Breazeale Reactor (PSBR), Neutron Activation Analysis (NAA) measurements. With Activity Predictor it has been demonstrated that the predicted spectra were less than satisfactory. In order to obtain better predicted spectra, a new detailed model for the RSEC NAA spectroscopy system with High Purity Germanium (HPGe) detector is developed using Geant-4. The model was validated with a National Bureau of Standards certified 60 Co source and tree activated high purity samples at PSBR. The predicted spectra agreed well with measured spectra. Error in net photo peak area values were 8.6-33.6%. Along with the previously developed activity predictor software, this new model in Geant-4 provided realistic spectra prediction for NAA experiments at RSEC PSBR. (author)

  13. Geant4 simulations of soft proton scattering in X-ray optics. A tentative validation using laboratory measurements

    Science.gov (United States)

    Fioretti, Valentina; Mineo, Teresa; Bulgarelli, Andrea; Dondero, Paolo; Ivanchenko, Vladimir; Lei, Fan; Lotti, Simone; Macculi, Claudio; Mantero, Alfonso

    2017-12-01

    Low energy protons (process responsible for the grazing angle scattering processes is mandatory to evaluate the impact of such events on the performance (e.g. observation time, sensitivity) of future X-ray telescopes as the ESA ATHENA mission. The Remizovich model describes particles reflected by solids at glancing angles in terms of the Boltzmann transport equation using the diffuse approximation and the model of continuous slowing down in energy. For the first time this solution, in the approximation of no energy losses, is implemented, verified, and qualitatively validated on top of the Geant4 release 10.2, with the possibility to add a constant energy loss to each interaction. This implementation is verified by comparing the simulated proton distribution to both the theoretical probability distribution and with independent ray-tracing simulations. Both the new scattering physics and the Coulomb scattering already built in the official Geant4 distribution are used to reproduce the latest experimental results on grazing angle proton scattering. At 250 keV multiple scattering delivers large proton angles and it is not consistent with the observation. Among the tested models, the single scattering seems to better reproduce the scattering efficiency at the three energies but energy loss obtained at small scattering angles is significantly lower than the experimental values. In general, the energy losses obtained in the experiment are higher than what obtained by the simulation. The experimental data are not completely representative of the soft proton scattering experienced by current X-ray telescopes because of the lack of measurements at low energies (distribution at the exit of X-ray optics.

  14. Calibration of the radiation monitor onboard Akebono using Geant4

    Science.gov (United States)

    Asai, Keiko; Takashima, Takeshi; Koi, Tatsumi; Nagai, Tsugunobu

    Natural high-energy electrons and protons (keV-MeV) in the space contaminate the data re-ciprocally. In order to calibrate the energy ranges and to remove data contamination on the radiation monitor (RDM) onboard the Japanese satellite, Akebono (EXOS-D), the detector is investigated using the Geant4 simulation toolkit of computational particle tracing. The semi-polar orbiting Akebono, launched in February 1989, is active now. This satellite has been observed the space environment at altitudes of several thousands km. The RDM instrument onboard Akebono monitors energetic particles in the Earth's radiation belt and gives important data accumulated for about two solar cycles. The data from RDM are for electrons in three energy channels of 0.3 MeV, protons in three energy channels of ¿ 30 MeV, and alpha particles in one energy channels of 15-45 MeV. The energy ranges are however based on information of about 20 years ago so that the data seem to include some errors actuary. In addition, these data include contamination of electrons and protons reciprocally. Actuary it is noticed that the electron data are contaminated by the solar protons but unknown quantitative amount of the contamination. Therefore we need data calibration in order to correct the energy ranges and to remove data contamination. The Geant4 simulation gives information of trajectories of incident and secondary particles whose are interacted with materials. We examine the RDM monitor using the Geant4 simulation. We find from the results that relativistic electrons of MeV behave quite complicatedly because of particle-material interaction in the instrument. The results indicate that efficiencies of detection and contamination are dependent on energy. This study compares the electron data from Akebono RDM with the simultaneous observation of CRRES and tries to lead the values of correction for each of the energy channels.

  15. Visualization drivers for Geant4

    International Nuclear Information System (INIS)

    Beretvas, Andy

    2005-01-01

    This document is on Geant 4 visualization tools (drivers), evaluating pros and cons of each option, including recommendations on which tools to support at Fermilab for different applications. Four visualization drivers are evaluated. They re OpenGL, HepRep, DAWN and VRML. They all have good features, OpenGL provides graphic output with out an intermediate file. HepRep provides menus to assist the user. DAWN provides high quality plots and even for large files produces output quickly. VRML uses the smallest disk space for intermediate files. Large experiments at Fermilab will want to write their own display. They should proceed to make this display graphics independent. Medium experiment will probably want to use HepRep because of it's menu support. Smaller scale experiments will want to use OpenGL in the spirit of having immediate response, good quality output and keeping things simple

  16. Behaviors of the percentage depth dose curves along the beam axis of a phantom filled with different clinical PTO objects, a Monte Carlo Geant4 study

    International Nuclear Information System (INIS)

    EL Bakkali, Jaafar; EL Bardouni, Tarek; Safavi, Seyedmostafa; Mohammed, Maged; Saeed, Mroan

    2016-01-01

    The aim of this work is to assess the capabilities of Monte Carlo Geant4 code to reproduce the real percentage depth dose (PDD) curves generated in phantoms which mimic three important clinical treatment situations that include lung slab, bone slab, bone-lung slab geometries. It is hoped that this work will lead us to a better understanding of dose distributions in an inhomogeneous medium, and to identify any limitations of dose calculation algorithm implemented in the Geant4 code. For this purpose, the PDD dosimetric functions associated to the three clinical situations described above, were compared to one produced in a homogeneous water phantom. Our results show, firstly, that the Geant4 simulation shows potential mistakes on the shape of the calculated PDD curve of the first physical test object (PTO), and it is obviously not able to successfully predict dose values in regions near to the boundaries between two different materials. This is, surely due to the electron transport algorithm and it is well-known as the artifacts at interface phenomenon. To deal with this issue, we have added and optimized the StepMax parameter to the dose calculation program; consequently the artifacts due to the electron transport were quasi disappeared. However, the Geant4 simulation becomes painfully slow when we attempt to completely resolve the electron artifact problems by considering a smaller value of an electron StepMax parameter. After electron transport optimization, our results demonstrate the medium-level capabilities of the Geant4 code to modeling dose distribution in clinical PTO objects. - Highlights: • Assessment of the capabilities of Geant4 code to reproduce the PDD curves in heterogeneities. • Resolving artifacts due to the electron transport. • Understanding in dose distribution differences in interfaces which include water, bone, and lung interfaces.

  17. Extension of PENELOPE to protons: Simulation of nuclear reactions and benchmark with Geant4

    International Nuclear Information System (INIS)

    Sterpin, E.; Sorriaux, J.; Vynckier, S.

    2013-01-01

    Purpose: Describing the implementation of nuclear reactions in the extension of the Monte Carlo code (MC) PENELOPE to protons (PENH) and benchmarking with Geant4.Methods: PENH is based on mixed-simulation mechanics for both elastic and inelastic electromagnetic collisions (EM). The adopted differential cross sections for EM elastic collisions are calculated using the eikonal approximation with the Dirac–Hartree–Fock–Slater atomic potential. Cross sections for EM inelastic collisions are computed within the relativistic Born approximation, using the Sternheimer–Liljequist model of the generalized oscillator strength. Nuclear elastic and inelastic collisions were simulated using explicitly the scattering analysis interactive dialin database for 1 H and ICRU 63 data for 12 C, 14 N, 16 O, 31 P, and 40 Ca. Secondary protons, alphas, and deuterons were all simulated as protons, with the energy adapted to ensure consistent range. Prompt gamma emission can also be simulated upon user request. Simulations were performed in a water phantom with nuclear interactions switched off or on and integral depth–dose distributions were compared. Binary-cascade and precompound models were used for Geant4. Initial energies of 100 and 250 MeV were considered. For cases with no nuclear interactions simulated, additional simulations in a water phantom with tight resolution (1 mm in all directions) were performed with FLUKA. Finally, integral depth–dose distributions for a 250 MeV energy were computed with Geant4 and PENH in a homogeneous phantom with, first, ICRU striated muscle and, second, ICRU compact bone.Results: For simulations with EM collisions only, integral depth–dose distributions were within 1%/1 mm for doses higher than 10% of the Bragg-peak dose. For central-axis depth–dose and lateral profiles in a phantom with tight resolution, there are significant deviations between Geant4 and PENH (up to 60%/1 cm for depth–dose distributions). The agreement is much

  18. Extension of PENELOPE to protons: simulation of nuclear reactions and benchmark with Geant4.

    Science.gov (United States)

    Sterpin, E; Sorriaux, J; Vynckier, S

    2013-11-01

    Describing the implementation of nuclear reactions in the extension of the Monte Carlo code (MC) PENELOPE to protons (PENH) and benchmarking with Geant4. PENH is based on mixed-simulation mechanics for both elastic and inelastic electromagnetic collisions (EM). The adopted differential cross sections for EM elastic collisions are calculated using the eikonal approximation with the Dirac-Hartree-Fock-Slater atomic potential. Cross sections for EM inelastic collisions are computed within the relativistic Born approximation, using the Sternheimer-Liljequist model of the generalized oscillator strength. Nuclear elastic and inelastic collisions were simulated using explicitly the scattering analysis interactive dialin database for (1)H and ICRU 63 data for (12)C, (14)N, (16)O, (31)P, and (40)Ca. Secondary protons, alphas, and deuterons were all simulated as protons, with the energy adapted to ensure consistent range. Prompt gamma emission can also be simulated upon user request. Simulations were performed in a water phantom with nuclear interactions switched off or on and integral depth-dose distributions were compared. Binary-cascade and precompound models were used for Geant4. Initial energies of 100 and 250 MeV were considered. For cases with no nuclear interactions simulated, additional simulations in a water phantom with tight resolution (1 mm in all directions) were performed with FLUKA. Finally, integral depth-dose distributions for a 250 MeV energy were computed with Geant4 and PENH in a homogeneous phantom with, first, ICRU striated muscle and, second, ICRU compact bone. For simulations with EM collisions only, integral depth-dose distributions were within 1%/1 mm for doses higher than 10% of the Bragg-peak dose. For central-axis depth-dose and lateral profiles in a phantom with tight resolution, there are significant deviations between Geant4 and PENH (up to 60%/1 cm for depth-dose distributions). The agreement is much better with FLUKA, with deviations within

  19. The simulation of an imaging gamma-ray Compton backscattering device using GEANT4

    International Nuclear Information System (INIS)

    Flechas, D.; Cristancho, F.; Sarmiento, L.G.; Fajardo, E.

    2014-01-01

    A gamma-backscattering imaging device dubbed Compton Camera, developed at GSI (Darmstadt, Germany) and modified and studied at the Nuclear Physics Group of the National University of Colombia in Bogota, uses the back-to-back emission of two gamma rays in the positron annihilation to construct a bidimensional image that represents the distribution of matter in the field-of-view of the camera. This imaging capability can be used in a host of different situations, for example, to identify and study deposition and structural defects, and to help locating concealed objects, to name just two cases. In order to increase the understanding of the response of the Compton Camera and, in particular, its image formation process, and to assist in the data analysis, a simulation of the camera was developed using the GEANT4 simulation toolkit. In this work, the images resulting from different experimental conditions are shown. The simulated images and their comparison with the experimental ones already suggest methods to improve the present experimental device. (author)

  20. Optimisation of a dual head semiconductor Compton camera using Geant4

    Energy Technology Data Exchange (ETDEWEB)

    Harkness, L.J. [Department of Physics, University of Liverpool, Oliver Lodge Laboratory, Liverpool L697ZE (United Kingdom)], E-mail: ljh@ns.ph.liv.ac.uk; Boston, A.J.; Boston, H.C.; Cooper, R.J.; Cresswell, J.R.; Grint, A.N.; Nolan, P.J.; Oxley, D.C.; Scraggs, D.P. [Department of Physics, University of Liverpool, Oliver Lodge Laboratory, Liverpool L697ZE (United Kingdom); Beveridge, T.; Gillam, J. [School of Physics and Materials Engineering, Monash University, Melbourne (Australia); Lazarus, I. [STFC Daresbury Laboratory, Warrington, Cheshire (United Kingdom)

    2009-06-01

    Conventional medical gamma-ray camera systems utilise mechanical collimation to provide information on the position of an incident gamma-ray photon. Systems that use electronic collimation utilising Compton image reconstruction techniques have the potential to offer huge improvements in sensitivity. Position sensitive high purity germanium (HPGe) detector systems are being evaluated as part of a single photon emission computed tomography (SPECT) Compton camera system. Data have been acquired from the orthogonally segmented planar SmartPET detectors, operated in Compton camera mode. The minimum gamma-ray energy which can be imaged by the current system in Compton camera configuration is 244 keV due to the 20 mm thickness of the first scatter detector which causes large gamma-ray absorption. A simulation package for the optimisation of a new semiconductor Compton camera has been developed using the Geant4 toolkit. This paper will show results of preliminary analysis of the validated Geant4 simulation for gamma-ray energies of SPECT, 141 keV.

  1. GePEToS: A Geant4 Monte Carlo simulation package for positron emission tomography

    International Nuclear Information System (INIS)

    Jan, Sebastien; Collot, Johann; Gallin-Martel, Marie-Laure; Martin, Philippe; Mayet, Frederic; Tournefier, Edwige

    2003-01-01

    GePEToS is a simulation framework developed over the last few years for assessing the instrumental performance of future PET scanners. It is based on Geant4, written in Object- Oriented C++ and runs on Linux platforms. The validity of GePEToS has been tested on the well-known Siemens ECAT EXACT HR+ camera. The results of two application examples are presented: the design optimization of a liquid Xe μPET camera dedicated to small animal imaging as well as the evaluation of the effect of a strong axial magnetic field on the image resolution of a Concorde P4 μPET camera. Index Terms-Positron Emission Tomography, Monte Carlo Simulation, Geant 4. (authors)

  2. A Geant4 evaluation of the Hornyak button and two candidate detectors for the TREAT hodoscope

    Science.gov (United States)

    Fu, Wenkai; Ghosh, Priyarshini; Harrison, Mark J.; McGregor, Douglas S.; Roberts, Jeremy A.

    2018-05-01

    The performance of traditional Hornyak buttons and two proposed variants for fast-neutron hodoscope applications was evaluated using Geant4. The Hornyak button is a ZnS(Ag)-based device previously deployed at the Idaho National Laboratory's TRansient REActor Test Facility (better known as TREAT) for monitoring fast neutrons emitted during pulsing of fissile fuel samples. Past use of these devices relied on pulse-shape discrimination to reduce the significant levels of background Cherenkov radiation. Proposed are two simple designs that reduce the overall light guide mass (here, polymethyl methacrylate or PMMA), employ silicon photomultipliers (SiPMs), and can be operated using pulse-height discrimination alone to eliminate background noise to acceptable levels. Geant4 was first used to model a traditional Hornyak button, and for assumed, hodoscope-like conditions, an intrinsic efficiency of 0.35% for mono-directional fission neutrons was predicted. The predicted efficiency is in reasonably good agreement with experimental data from the literature and, hence, served to validate the physics models and approximations employed. Geant4 models were then developed to optimize the materials and geometries of two alternatives to the Hornyak button, one based on a homogeneous mixture of ZnS(Ag) and PMMA, and one based on alternating layers of ZnS(Ag) and PMMA oriented perpendicular to the incident neutron beam. For the same radiation environment, optimized, 5-cm long (along the beam path) devices of the homogeneous and layered designs were predicted to have efficiencies of approximately 1.3% and 3.3%, respectively. For longer devices, i.e., lengths larger than 25 cm, these efficiencies were shown to peak at approximately 2.2% and 5.9%, respectively. Moreover, both designs were shown to discriminate Cherenkov noise intrinsically by using an appropriate pulse-height discriminator level, i.e., pulse-shape discrimination is not needed for these devices.

  3. Benchmarking nuclear models of FLUKA and GEANT4 for carbon ion therapy

    CERN Document Server

    Bohlen, TT; Quesada, J M; Bohlen, T T; Cerutti, F; Gudowska, I; Ferrari, A; Mairani, A

    2010-01-01

    As carbon ions, at therapeutic energies, penetrate tissue, they undergo inelastic nuclear reactions and give rise to significant yields of secondary fragment fluences. Therefore, an accurate prediction of these fluences resulting from the primary carbon interactions is necessary in the patient's body in order to precisely simulate the spatial dose distribution and the resulting biological effect. In this paper, the performance of nuclear fragmentation models of the Monte Carlo transport codes, FLUKA and GEANT4, in tissue-like media and for an energy regime relevant for therapeutic carbon ions is investigated. The ability of these Monte Carlo codes to reproduce experimental data of charge-changing cross sections and integral and differential yields of secondary charged fragments is evaluated. For the fragment yields, the main focus is on the consideration of experimental approximations and uncertainties such as the energy measurement by time-of-flight. For GEANT4, the hadronic models G4BinaryLightIonReaction a...

  4. Statistical Analysis Methods for Physics Models Verification and Validation

    CERN Document Server

    De Luca, Silvia

    2017-01-01

    The validation and verification process is a fundamental step for any software like Geant4 and GeantV, which aim to perform data simulation using physics models and Monte Carlo techniques. As experimental physicists, we have to face the problem to compare the results obtained using simulations with what the experiments actually observed. One way to solve the problem is to perform a consistency test. Within the Geant group, we developed a C++ compact library which will be added to the automated validation process on the Geant Validation Portal

  5. Monte Carlo Simulation of Electron Beams for Radiotherapy - EGS4, MCNP4b and GEANT3 Intercomparison

    CERN Document Server

    Trindade, A; Alves, C M; Chaves, A; Lopes, C; Oliveira, C; Peralta, L

    2000-01-01

    In medical radiation physics, an increasing number of Monte Carlo codes are being used, which requires intercomparison between them to evaluated the accuracy of the simulated results against benchmark experiments. The Monte Carlo code EGS4, commonly used to simulate electron beams from medical linear accelerators, was compared with GEANT3 and MCNP4b. Intercomparison of electron energy spectra, angular and spatial distribution were carried out for the Siemens KD2 linear accelerator, at beam energies of 10 and 15 MeV for a field size of 10x10 cm2. Indirect validation was performed against electron depth doses curves and beam profiles measured in a MP3-PTW water phantom using a Markus planar chamber. Monte Carlo isodose lines were reconstructed and compared to those from commercial treatment planning systems (TPS's) and with experimental data.

  6. A Geant4 simulation of the depth dose percentage in brain tumors treatments using protons and carbon ions

    Energy Technology Data Exchange (ETDEWEB)

    Diaz, José A. M., E-mail: joadiazme@unal.edu.co; Torres, D. A., E-mail: datorresg@unal.edu.co [Physics Department, Universidad Nacional de Colombia, Bogot (Colombia)

    2016-07-07

    The deposited energy and dose distribution of beams of protons and carbon over a head are simulated using the free tool package Geant4 and the data analysis package ROOT-C++. The present work shows a methodology to understand the microscopical process occurring in a session of hadron-therapy using advance simulation tools.

  7. Simulation of AntiMatter–Matter Interactions in Geant4

    Directory of Open Access Journals (Sweden)

    Galoyan Aida

    2018-01-01

    Full Text Available Cross sections of antiproton and antinucleus interactions with nuclei are calculated using stochastic averaging method. A new implementation of the Quark-Gluon-String Model (QGSM is proposed for simulation of multi-particle production in antinucleus-nucleus collisions. A combination of the cross sections and the new implementation of QGSM allows experimental data on antiproton and antinucleus interactions with nuclei to be described. The combination is included in the well-known Geant4 simulation toolkit.

  8. Comparative analysis of the sensitivity of the scanner rSPECT: using GAMOS: a Geant4-based framework

    International Nuclear Information System (INIS)

    Martinez Turtos, Rosana; Diaz Garcia, Angelina; Abreu Alfonso, Yamiel; Arteche, Jossue; Leyva Pernia, Diana

    2012-01-01

    The molecular imaging of cellular processes in vivo using preclinical animal studies and SPECT technique is one of the main reasons for the design of new devices with high spatial resolution. As an auxiliary tool, Monte Carlo simulation has allowed the characterization and optimization of those medical imaging systems effectively. At present there is a new simulation framework called GAMOS (GEANT4-based Architecture for Medicine-Oriented Simulations); which code, libraries and particle transport method correspond to those developed by GEANT4 and contains specific applications for nuclear medicine. This tool has been already validated for PET technique by comparison with experimental data, while not yet been done the correct evaluation of GAMOS for SPECT systems. Present work have demonstrated the potential of GAMOS in obtaining simulated realistic data using this nuclear imaging technique. For this purpose, simulation of a novel installation 'rSPECT' ,dedicated to the study of rodents, has been done. The study comprises the collimation and detection geometries and the fundamental characteristics of the previous published experimental measurements for rSPECT installation. Studies have been done using 99mTc and 20% energy window. Sensitivity values obtained by simulation revealed an acceptable agreement with experimental values. Therefore we can conclude that simulation results have shown good agreement with the real data. This fact allowed to estimate the behavior of the new GEANT4 simulation platform 'GAMOS' in SPECT applications and have demonstrated the feasibility of reproducing experimental data. (author)

  9. Design and construction of a graphical interface for automatic generation of simulation code GEANT4

    International Nuclear Information System (INIS)

    Driss, Mozher; Bouzaine Ismail

    2007-01-01

    This work is set in the context of the engineering studies final project; it is accomplished in the center of nuclear sciences and technologies in Sidi Thabet. This project is about conceiving and developing a system based on graphical user interface which allows an automatic codes generation for simulation under the GEANT4 engine. This system aims to facilitate the use of GEANT4 by scientific not necessary expert in this engine and to be used in different areas: research, industry and education. The implementation of this project uses Root library and several programming languages such as XML and XSL. (Author). 5 refs

  10. Geant4 simulations of the absorption of photons in CsI and NaI produced by electrons with energies up to 4 MeV and their application to precision measurements of the β-energy spectrum with a calorimetric technique

    Science.gov (United States)

    Huyan, X.; Naviliat-Cuncic, O.; Voytas, P.; Chandavar, S.; Hughes, M.; Minamisono, K.; Paulauskas, S. V.

    2018-01-01

    The yield of photons produced by electrons slowing down in CsI and NaI was studied with four electromagnetic physics constructors included in the Geant4 toolkit. The subsequent absorption of photons in detector geometries used for measurements of the β spectrum shape was also studied with a focus on the determination of the absorption fraction. For electrons with energies in the range 0.5-4 MeV, the relative photon yields determined with the four Geant4 constructors differ at the level of 10-2 in amplitude and the relative absorption fractions differ at the level of 10-4 in amplitude. The differences among constructors enabled the estimation of the sensitivity to Geant4 simulations for the measurement of the β energy spectrum shape in 6He decay using a calorimetric technique with ions implanted in the active volume of detectors. The size of the effect associated with photons escaping the detectors was quantified in terms of a slope which, on average, is respectively - 5 . 4 %/MeV and - 4 . 8 %/MeV for the CsI and NaI geometries. The corresponding relative uncertainties as determined from the spread of results obtained with the four Geant4 constructors are 0.0067 and 0.0058.

  11. Study of x-ray fluorescence : Development in Geant4 of new models of cross sections for simulation PIXE. Biological and archaeological applications

    International Nuclear Information System (INIS)

    Ben Abdelouahed, Haifa

    2010-01-01

    a great number of times, that makes it possible to reproduce the macroscopic effects and to calculate sizes like, in our case, x-ray fluorescence. Among several tools available for Monte Carlo simulation of the interactions particle-matter, the tool for simulation Monte Carlo Geant4 is characterized by a particularly flexible architecture based on directed technology object. This is why, to build our code of simulation, our choice was fixed on the use of this tool. We treat in the first chapter the guiding principle of x-ray fluorescence, which leads us to present the various phenomena which limit its sensitivity of analysis. We devote the second chapter to the presentation of the Geant4 tool, and our tests of validation of its electromagnetic processes. We describe the performances and the limits of this tool as for the simulation of the cross sections. We will expose in this same chapter our development, in the Geant4 tool, of new models of calculation of the cross sections of ionization of the atoms by the protons and the particles alpha. We discuss also our method of validation of the models in question. This work was object of publication. It was taken into account by the Geant4 project: our development currently replaces the data base EEDL of Geant4 in the process of determination of the cross sections of ionization by charged particles, and makes thus functional the Geant4 tool in the simulation of the x-ray fluorescence induced by charged particles. We describe in the third chapter our use of the code worked out for the simulation of the effectiveness of absorption of the standard Si(Li) detector which constitutes the essential piece of our device of analysis by x-ray fluorescence. We expose the adopted approach which enabled us to optimize the geometrical parameters of the studied detector. This work was presented at the second international conference of spectroscopy. We present, in the fourth chapter, some examples of concrete applications on the study of

  12. A fast and complete GEANT4 and ROOT Object-Oriented Toolkit: GROOT

    Science.gov (United States)

    Lattuada, D.; Balabanski, D. L.; Chesnevskaya, S.; Costa, M.; Crucillà, V.; Guardo, G. L.; La Cognata, M.; Matei, C.; Pizzone, R. G.; Romano, S.; Spitaleri, C.; Tumino, A.; Xu, Y.

    2018-01-01

    Present and future gamma-beam facilities represent a great opportunity to validate and evaluate the cross-sections of many photonuclear reactions at near-threshold energies. Monte Carlo (MC) simulations are very important to evaluate the reaction rates and to maximize the detection efficiency but, unfortunately, they can be very cputime-consuming and in some cases very hard to reproduce, especially when exploring near-threshold cross-section. We developed a software that makes use of the validated tracking GEANT4 libraries and the n-body event generator of ROOT in order to provide a fast, realiable and complete MC tool to be used for nuclear physics experiments. This tool is indeed intended to be used for photonuclear reactions at γ-beam facilities with ELISSA (ELI Silicon Strip Array), a new detector array under development at the Extreme Light Infrastructure - Nuclear Physics (ELI-NP). We discuss the results of MC simulations performed to evaluate the effects of the electromagnetic induced background, of the straggling due to the target thickness and of the resolution of the silicon detectors.

  13. SU-E-T-05: Comparing DNA Strand Break Yields for Photons under Different Irradiation Conditions with Geant4-DNA.

    Science.gov (United States)

    Pater, P; Bernal, M; Naqa, I El; Seuntjens, J

    2012-06-01

    To validate and scrutinize published DNA strand break data with Geant4-DNA and a probabilistic model. To study the impact of source size, electronic equilibrium and secondary electron tracking cutoff on direct relative biological effectiveness (DRBE). Geant4 (v4.9.5) was used to simulate a cylindrical region of interest (ROI) with r = 15 nm and length = 1.05 mm, in a slab of liquid water of 1.06 g/cm 3 density. The ROI was irradiated with mono-energetic photons, with a uniformly distributed volumetric isotropic source (0.28, 1.5 keV) or a plane beam (0.662, 1.25 MeV), of variable size. Electrons were tracked down to 50 or 10 eV, with G4-DNA processes and energy transfer greater than 10.79 eV was scored. Based on volume ratios, each scored event had a 0.0388 probability of happening on either DNA helix (break). Clusters of at least one break on each DNA helix within 3.4 nm were found using a DBSCAN algorithm and categorized as double strand breaks (DSB). All other events were categorized as single strand breaks (SSB). Geant4-DNA is able to reproduce strand break yields previously published. Homogeneous irradiation conditions should be present throughout the ROI for DRBE comparisons. SSB yields seem slightly dependent on the primary photon energy. DRBEs show a significant increasing trend for lower energy incident photons. A lower electron cutoff produces higher SSB yields, but decreases the SSB/DSB yields ratio. The probabilistic and geometrical DNA models can predict equivalent results. Using Geant4, we were able to reproduce previously published results on the direct strand break yields of photon and study the importance of irradiation conditions. We also show an ascending trend for DRBE with lower incident photon energies. A probabilistic model coupled with track structure analysis can be used to simulate strand break yields. NSERC, CIHR. © 2012 American Association of Physicists in Medicine.

  14. Comparison of Geant4-DNA simulation of S-values with other Monte Carlo codes

    International Nuclear Information System (INIS)

    André, T.; Morini, F.; Karamitros, M.; Delorme, R.; Le Loirec, C.; Campos, L.; Champion, C.; Groetz, J.-E.; Fromm, M.; Bordage, M.-C.; Perrot, Y.; Barberet, Ph.

    2014-01-01

    Monte Carlo simulations of S-values have been carried out with the Geant4-DNA extension of the Geant4 toolkit. The S-values have been simulated for monoenergetic electrons with energies ranging from 0.1 keV up to 20 keV, in liquid water spheres (for four radii, chosen between 10 nm and 1 μm), and for electrons emitted by five isotopes of iodine (131, 132, 133, 134 and 135), in liquid water spheres of varying radius (from 15 μm up to 250 μm). The results have been compared to those obtained from other Monte Carlo codes and from other published data. The use of the Kolmogorov–Smirnov test has allowed confirming the statistical compatibility of all simulation results

  15. Exploring the Physics Limitations of Compact High Gradient Accelerating Structures Simulations of the Electron Current Spectrometer Setup in Geant4

    CERN Document Server

    Van Vliet, Philine Julia

    2017-01-01

    The high field gradient of 100 MV/m that will be applied to the accelerator cavities of the Compact Linear Collider (CLIC), gives rise to the problem of RF breakdowns. The field collapses and a plasma of electrons and ions is being formed in the cavity, preventing the RF field from penetrating the cavity. Electrons in the plasma are being accelerated and ejected out, resulting in a breakdown current up to a few Amp`eres, measured outside the cavities. These breakdowns lead to luminosity loss, so reducing their amount is of great importance. For this, a better understanding of the physics behind RF breakdowns is needed. To study these breakdowns, the XBox 2 test facility has a spectrometer setup installed after the RF cavity that is being conditioned. For this report, a simulation of this spectrometer setup has been made using Geant4. Once a detailed simulation of the RF field and cavity has been made, it can be connected to this simulation of the spectrometer setup and used to recreate the data that has b...

  16. An Algorithm for Computing Screened Coulomb Scattering in Geant4

    OpenAIRE

    Mendenhall, Marcus H.; Weller, Robert A.

    2004-01-01

    An algorithm has been developed for the Geant4 Monte-Carlo package for the efficient computation of screened Coulomb interatomic scattering. It explicitly integrates the classical equations of motion for scattering events, resulting in precise tracking of both the projectile and the recoil target nucleus. The algorithm permits the user to plug in an arbitrary screening function, such as Lens-Jensen screening, which is good for backscattering calculations, or Ziegler-Biersack-Littmark screenin...

  17. Simulation and Digitization of a Gas Electron Multiplier Detector Using Geant4 and an Object-Oriented Digitization Program

    Science.gov (United States)

    McMullen, Timothy; Liyanage, Nilanga; Xiong, Weizhi; Zhao, Zhiwen

    2017-01-01

    Our research has focused on simulating the response of a Gas Electron Multiplier (GEM) detector using computational methods. GEM detectors provide a cost effective solution for radiation detection in high rate environments. A detailed simulation of GEM detector response to radiation is essential for the successful adaption of these detectors to different applications. Using Geant4 Monte Carlo (GEMC), a wrapper around Geant4 which has been successfully used to simulate the Solenoidal Large Intensity Device (SoLID) at Jefferson Lab, we are developing a simulation of a GEM chamber similar to the detectors currently used in our lab. We are also refining an object-oriented digitization program, which translates energy deposition information from GEMC into electronic readout which resembles the readout from our physical detectors. We have run the simulation with beta particles produced by the simulated decay of a 90Sr source, as well as with a simulated bremsstrahlung spectrum. Comparing the simulation data with real GEM data taken under similar conditions is used to refine the simulation parameters. Comparisons between results from the simulations and results from detector tests will be presented.

  18. Simulation of ALTEA calibration data with PHITS, FLUKA and GEANT4

    International Nuclear Information System (INIS)

    La Tessa, C.; Di Fino, L.; Larosa, M.; Lee, K.; Mancusi, D.; Matthiae, D.; Narici, L.; Zaconte, V.

    2009-01-01

    The ALTEA-Space detector has been calibrated by testing its response to several monochromatic beams. These measurements provided energy-deposition spectra in silicon of 100, 600 and 1000 MeV/nucleon 12 C and 200 and 600 MeV/nucleon 48 Ti. The results have been compared to three Monte Carlo transport codes, namely PHITS, GEANT4 and FLUKA. Median, full width at half maximum (FWHM) and interquartile range (IQR) have been calculated for all datasets to characterize location, width and asymmetry of the energy-deposition spectra. Particular attention has been devoted to the influence of δ rays on the shape of the energy-deposition spectrum, both with the help of analytical calculations and Monte Carlo simulations. The two approaches proved that, in this range of projectile charge, projectile energy and detector size, the leakage of secondary electrons might introduce a difference between the energy-loss and energy-deposition spectrum, in particular by changing the location, width and symmetry of the distribution. The overall agreement between the Monte Carlo predictions and the measurements is fair and makes PHITS, FLUKA and GEANT4 all possible candidates for simulating ALTEA-Space experiment.

  19. Monte Carlo simulation of a photodisintegration of 3 H experiment in Geant4

    Science.gov (United States)

    Gray, Isaiah

    2013-10-01

    An upcoming experiment involving photodisintegration of 3 H at the High Intensity Gamma-Ray Source facility at Duke University has been simulated in the software package Geant4. CAD models of silicon detectors and wire chambers were imported from Autodesk Inventor using the program FastRad and the Geant4 GDML importer. Sensitive detectors were associated with the appropriate logical volumes in the exported GDML file so that changes in detector geometry will be easily manifested in the simulation. Probability distribution functions for the energy and direction of outgoing protons were generated using numerical tables from previous theory, and energies and directions were sampled from these distributions using a rejection sampling algorithm. The simulation will be a useful tool to optimize detector geometry, estimate background rates, and test data analysis algorithms. This work was supported by the Triangle Universities Nuclear Laboratory REU program at Duke University.

  20. Simulations of GCR interactions within planetary bodies using GEANT4

    Science.gov (United States)

    Mesick, K.; Feldman, W. C.; Stonehill, L. C.; Coupland, D. D. S.

    2017-12-01

    On planetary bodies with little to no atmosphere, Galactic Cosmic Rays (GCRs) can hit the body and produce neutrons primarily through nuclear spallation within the top few meters of the surfaces. These neutrons undergo further nuclear interactions with elements near the planetary surface and some will escape the surface and can be detected by landed or orbiting neutron radiation detector instruments. The neutron leakage signal at fast neutron energies provides a measure of average atomic mass of the near-surface material and in the epithermal and thermal energy ranges is highly sensitive to the presence of hydrogen. Gamma-rays can also escape the surface, produced at characteristic energies depending on surface composition, and can be detected by gamma-ray instruments. The intra-nuclear cascade (INC) that occurs when high-energy GCRs interact with elements within a planetary surface to produce the leakage neutron and gamma-ray signals is highly complex, and therefore Monte Carlo based radiation transport simulations are commonly used for predicting and interpreting measurements from planetary neutron and gamma-ray spectroscopy instruments. In the past, the simulation code that has been widely used for this type of analysis is MCNPX [1], which was benchmarked against data from the Lunar Neutron Probe Experiment (LPNE) on Apollo 17 [2]. In this work, we consider the validity of the radiation transport code GEANT4 [3], another widely used but open-source code, by benchmarking simulated predictions of the LPNE experiment to the Apollo 17 data. We consider the impact of different physics model options on the results, and show which models best describe the INC based on agreement with the Apollo 17 data. The success of this validation then gives us confidence in using GEANT4 to simulate GCR-induced neutron leakage signals on Mars in relevance to a re-analysis of Mars Odyssey Neutron Spectrometer data. References [1] D.B. Pelowitz, Los Alamos National Laboratory, LA-CP-05

  1. Abstract ID: 176 Geant4 implementation of inter-atomic interference effect in small-angle coherent X-ray scattering for materials of medical interest.

    Science.gov (United States)

    Paternò, Gianfranco; Cardarelli, Paolo; Contillo, Adriano; Gambaccini, Mauro; Taibi, Angelo

    2018-01-01

    Advanced applications of digital mammography such as dual-energy and tomosynthesis require multiple exposures and thus deliver higher dose compared to standard mammograms. A straightforward manner to reduce patient dose without affecting image quality would be removal of the anti-scatter grid, provided that the involved reconstruction algorithms are able to take the scatter figure into account [1]. Monte Carlo simulations are very well suited for the calculation of X-ray scatter distribution and can be used to integrate such information within the reconstruction software. Geant4 is an open source C++ particle tracking code widely used in several physical fields, including medical physics [2,3]. However, the coherent scattering cross section used by the standard Geant4 code does not take into account the influence of molecular interference. According to the independent atomic scattering approximation (the so-called free-atom model), coherent radiation is indistinguishable from primary radiation because its angular distribution is peaked in the forward direction. Since interference effects occur between x-rays scattered by neighbouring atoms in matter, it was shown experimentally that the scatter distribution is affected by the molecular structure of the target, even in amorphous materials. The most important consequence is that the coherent scatter distribution is not peaked in the forward direction, and the position of the maximum is strongly material-dependent [4]. In this contribution, we present the implementation of a method to take into account inter-atomic interference in small-angle coherent scattering in Geant4, including a dedicated data set of suitable molecular form factor values for several materials of clinical interest. Furthermore, we present scatter images of simple geometric phantoms in which the Rayleigh contribution is rigorously evaluated. Copyright © 2017.

  2. Simulations of neutron transport at low energy: a comparison between GEANT and MCNP.

    Science.gov (United States)

    Colonna, N; Altieri, S

    2002-06-01

    The use of the simulation tool GEANT for neutron transport at energies below 20 MeV is discussed, in particular with regard to shielding and dose calculations. The reliability of the GEANT/MICAP package for neutron transport in a wide energy range has been verified by comparing the results of simulations performed with this package in a wide energy range with the prediction of MCNP-4B, a code commonly used for neutron transport at low energy. A reasonable agreement between the results of the two codes is found for the neutron flux through a slab of material (iron and ordinary concrete), as well as for the dose released in soft tissue by neutrons. These results justify the use of the GEANT/MICAP code for neutron transport in a wide range of applications, including health physics problems.

  3. Geant4 Hadronic Cascade Models and CMS Data Analysis : Computational Challenges in the LHC era

    CERN Document Server

    Heikkinen, Aatos

    This work belongs to the field of computational high-energy physics (HEP). The key methods used in this thesis work to meet the challenges raised by the Large Hadron Collider (LHC) era experiments are object-orientation with software engineering, Monte Carlo simulation, the computer technology of clusters, and artificial neural networks. The first aspect discussed is the development of hadronic cascade models, used for the accurate simulation of medium-energy hadron-nucleus reactions, up to 10 GeV. These models are typically needed in hadronic calorimeter studies and in the estimation of radiation backgrounds. Various applications outside HEP include the medical field (such as hadron treatment simulations), space science (satellite shielding), and nuclear physics (spallation studies). Validation results are presented for several significant improvements released in Geant4 simulation tool, and the significance of the new models for computing in the Large Hadron Collider era is estimated. In particular, we es...

  4. Efficiency transfer using the GEANT4 code of CERN for HPGe gamma spectrometry

    International Nuclear Information System (INIS)

    Chagren, S.; Tekaya, M.Ben; Reguigui, N.; Gharbi, F.

    2016-01-01

    In this work we apply the GEANT4 code of CERN to calculate the peak efficiency in High Pure Germanium (HPGe) gamma spectrometry using three different procedures. The first is a direct calculation. The second corresponds to the usual case of efficiency transfer between two different configurations at constant emission energy assuming a reference point detection configuration and the third, a new procedure, consists on the transfer of the peak efficiency between two detection configurations emitting the gamma ray in different energies assuming a “virtual” reference point detection configuration. No pre-optimization of the detector geometrical characteristics was performed before the transfer to test the ability of the efficiency transfer to reduce the effect of the ignorance on their real magnitude on the quality of the transferred efficiency. The obtained and measured efficiencies were found in good agreement for the two investigated methods of efficiency transfer. The obtained agreement proves that Monte Carlo method and especially the GEANT4 code constitute an efficient tool to obtain accurate detection efficiency values. The second investigated efficiency transfer procedure is useful to calibrate the HPGe gamma detector for any emission energy value for a voluminous source using one point source detection efficiency emitting in a different energy as a reference efficiency. The calculations preformed in this work were applied to the measurement exercise of the EUROMET428 project. A measurement exercise where an evaluation of the full energy peak efficiencies in the energy range 60–2000 keV for a typical coaxial p-type HpGe detector and several types of source configuration: point sources located at various distances from the detector and a cylindrical box containing three matrices was performed. - Highlights: • The GEANT4 code of CERN has been used to transfer the peak efficiency from point to points and voluminous detection configurations in HPGe gamma

  5. Dose calculation on voxels phantoms using the GEANT4 code

    International Nuclear Information System (INIS)

    Martins, Maximiano C.; Santos, Denison S.; Queiroz Filho, Pedro P.; Begalli, Marcia

    2009-01-01

    This work implemented an anthropomorphic phantom of voxels on the structure of Monte Carlo GEANT4, for utilization by professionals from the radioprotection, external dosimetry and medical physics. This phantom allows the source displacement that can be isotropic punctual, plain beam, linear or radioactive gas, in order to obtain diverse irradiation geometries. In them, the radioactive sources exposure is simulated viewing the determination of effective dose or the dose in each organ of the human body. The Zubal head and body trunk phantom was used, and we can differentiate the organs and tissues by the chemical constitution in soft tissue, lung tissue, bone tissue, water and air. The calculation method was validated through the comparison with other well established method, the Visual Monte Carlo (VMC). Besides, a comparison was done with the international recommendation for the evaluation of dose by exposure to punctual sources, described in the document TECDOC - 1162- Generic Procedures for Assessment and Response During a Radiological Emergency, where analytical expressions for this calculation are given. Considerations are made on the validity limits of these expressions for various irradiation geometries, including linear sources, immersion into clouds and contaminated soils

  6. BC404 scintillators as gamma locators studied via Geant4 simulations

    Science.gov (United States)

    Cortés, M. L.; Hoischen, R.; Eisenhauer, K.; Gerl, J.; Pietralla, N.

    2014-05-01

    In many applications in industry and academia, an accurate determination of the direction from where gamma rays are emitted is either needed or desirable. Ion-beam therapy treatments, the search for orphan sources, and homeland security applications are examples of fields that can benefit from directional sensitivity to gamma-radiation. Scintillation detectors are a good option for these types of applications as they have relatively low cost, are easy to handle and can be produced in a large range of different sizes. In this work a Geant4 simulation was developed to study the directional sensitivity of different BC404 scintillator geometries and arrangements. The simulation includes all the physical processes relevant for gamma detection in a scintillator. In particular, the creation and propagation of optical photons inside the scintillator was included. A simplified photomultiplier tube model was also simulated. The physical principle exploited is the angular dependence of the shape of the energy spectrum obtained from thin scintillator layers when irradiated from different angles. After an experimental confirmation of the working principle of the device and a check of the simulation, the possibilities and limitations of directional sensitivity to gamma radiation using scintillator layers was tested. For this purpose, point-like sources of typical energies expected in ion-beam therapy were used. Optimal scintillator thicknesses for different energies were determined and the setup efficiencies calculated. The use of arrays of scintillators to reconstruct the direction of incoming gamma rays was also studied. For this case, a spherical source emitting Bremsstrahlung radiation was used together with a setup consisting of scintillator layers. The capability of this setup to identify the center of the extended source was studied together with its angular resolution.

  7. Geant4-based simulations of charge collection in CMOS Active Pixel Sensors

    International Nuclear Information System (INIS)

    Esposito, M.; Allinson, N.M.; Price, T.; Anaxagoras, T.

    2017-01-01

    Geant4 is an object-oriented toolkit for the simulation of the interaction of particles and radiation with matter. It provides a snapshot of the state of a simulated particle in time, as it travels through a specified geometry. One important area of application is the modelling of radiation detector systems. Here, we extend the abilities of such modelling to include charge transport and sharing in pixelated CMOS Active Pixel Sensors (APSs); though similar effects occur in other pixel detectors. The CMOS APSs discussed were developed in the framework of the PRaVDA consortium to assist the design of custom sensors to be used in an energy-range detector for proton Computed Tomography (pCT). The development of ad-hoc classes, providing a charge transport model for a CMOS APS and its integration into the standard Geant4 toolkit, is described. The proposed charge transport model includes, charge generation, diffusion, collection, and sharing across adjacent pixels, as well as the full electronic chain for a CMOS APS. The proposed model is validated against experimental data acquired with protons in an energy range relevant for pCT.

  8. The study of response of wide band gap semiconductor detectors using the Geant4

    Directory of Open Access Journals (Sweden)

    Hussain Riaz

    2014-01-01

    Full Text Available The energy dependence on the intrinsic efficiency, absolute efficiency, full energy peak absolute efficiency and peak-to-total ratio have been studied for various wide band gap semiconductor detectors using the Geant4 based Monte Carlo simulations. The detector thickness of 1-4 mm and the area in 16-100 mm2 range were considered in this work. In excellent agreement with earlier work (Rybka et al., [20], the Geant4 simulated values of detector efficiencies have been found to decrease with incident g-ray energy. Both for the detector thickness and the detector area, the increasing trends have been observed for total efficiency as well as for full-energy peak efficiency in 0.1 MeV-50 MeV range. For Cd1-xZnxTe, the detector response remained insensitive to changes in relative proportions of Zn. For various wide band gap detectors studied in this work, the detection efficiency of TlBr was found highest over the entire range of energy, followed by the HgI2, CdTe, and then by CZT.

  9. Proton and electron deep dose profiles for retinoblastoma based on GEANT 4 code

    International Nuclear Information System (INIS)

    Braga, Flavia V.; Campos, Tarcisio P.R. de; Ribeiro, Kilder L.

    2009-01-01

    Herein, the dosimetry responses to a retinoblastoma proton and electron radiation therapy were investigated. The computational tool applied to this simulation was the Geant4 code, version 4.9.1. The code allows simulating the charge particle interaction with eyeball tissue. In the present simulation, a box of 4 cm side water filled had represented the human eye. The simulation was performed considering mono energetic beams of protons and electrons with spectra of 57 to 70 MeV for protons and 2 to 8 MeV for electrons. The simulation was guide by the advanced hadron therapy example distributed with the Geant4 code. The phantom was divided in voxels with 0.2 mm side. The energy deposited in each voxel was evaluated taken the direct beam at one face. The simulation results show the delivery energy and therefore the dose deposited in each voxel. The deep dose profiles to proton and electron were plotted. The well known Bragg peak was reproduced for protons. The maximum delivered dose defined the position at the proton stopped. However, to electrons, the absorbed energies were delivered along its path producing a more continuous distribution following the water depth, but also being stopped in the end of its path. (author)

  10. Proton and electron deep dose profiles for retinoblastoma based on GEANT 4 code

    Energy Technology Data Exchange (ETDEWEB)

    Braga, Flavia V., E-mail: flaviafisica@gmail.co [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Programa de Pos-graduacao em Ciencias e Tecnicas Nucleares; Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Campos, Tarcisio P.R. de [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Programa de Pos-graduacao em Ciencias e Tecnicas Nucleares; Ribeiro, Kilder L., E-mail: kilderlr@gmail.co [Universidade Estadual de Feira de Santana (UEFS), BA (Brazil). Dept. de Fisica

    2009-07-01

    Herein, the dosimetry responses to a retinoblastoma proton and electron radiation therapy were investigated. The computational tool applied to this simulation was the Geant4 code, version 4.9.1. The code allows simulating the charge particle interaction with eyeball tissue. In the present simulation, a box of 4 cm side water filled had represented the human eye. The simulation was performed considering mono energetic beams of protons and electrons with spectra of 57 to 70 MeV for protons and 2 to 8 MeV for electrons. The simulation was guide by the advanced hadron therapy example distributed with the Geant4 code. The phantom was divided in voxels with 0.2 mm side. The energy deposited in each voxel was evaluated taken the direct beam at one face. The simulation results show the delivery energy and therefore the dose deposited in each voxel. The deep dose profiles to proton and electron were plotted. The well known Bragg peak was reproduced for protons. The maximum delivered dose defined the position at the proton stopped. However, to electrons, the absorbed energies were delivered along its path producing a more continuous distribution following the water depth, but also being stopped in the end of its path. (author)

  11. A Compton camera application for the GAMOS GEANT4-based framework

    Energy Technology Data Exchange (ETDEWEB)

    Harkness, L.J., E-mail: ljh@ns.ph.liv.ac.uk [Oliver Lodge Laboratory, The University of Liverpool, Liverpool L69 7ZE (United Kingdom); Arce, P. [Department of Basic Research, CIEMAT, Madrid (Spain); Judson, D.S.; Boston, A.J.; Boston, H.C.; Cresswell, J.R.; Dormand, J.; Jones, M.; Nolan, P.J.; Sampson, J.A.; Scraggs, D.P.; Sweeney, A. [Oliver Lodge Laboratory, The University of Liverpool, Liverpool L69 7ZE (United Kingdom); Lazarus, I.; Simpson, J. [STFC Daresbury Laboratory, Daresbury, Warrington WA4 4AD (United Kingdom)

    2012-04-11

    Compton camera systems can be used to image sources of gamma radiation in a variety of applications such as nuclear medicine, homeland security and nuclear decommissioning. To locate gamma-ray sources, a Compton camera employs electronic collimation, utilising Compton kinematics to reconstruct the paths of gamma rays which interact within the detectors. The main benefit of this technique is the ability to accurately identify and locate sources of gamma radiation within a wide field of view, vastly improving the efficiency and specificity over existing devices. Potential advantages of this imaging technique, along with advances in detector technology, have brought about a rapidly expanding area of research into the optimisation of Compton camera systems, which relies on significant input from Monte-Carlo simulations. In this paper, the functionality of a Compton camera application that has been integrated into GAMOS, the GEANT4-based Architecture for Medicine-Oriented Simulations, is described. The application simplifies the use of GEANT4 for Monte-Carlo investigations by employing a script based language and plug-in technology. To demonstrate the use of the Compton camera application, simulated data have been generated using the GAMOS application and acquired through experiment for a preliminary validation, using a Compton camera configured with double sided high purity germanium strip detectors. Energy spectra and reconstructed images for the data sets are presented.

  12. New networking solutions support GEANT2

    CERN Multimedia

    2006-01-01

    "Researchers across the globe are benefiting from new advanced networking solutions, deployed as part of the GEANT2. For the first time, scientists collaborating on the world's largest particle physics experiment, the Large Hadron Collider (LHC), now have access to point-to-point network connections between distributed research centres." (1 page)

  13. Efficient voxel navigation for proton therapy dose calculation in TOPAS and Geant4

    Science.gov (United States)

    Schümann, J.; Paganetti, H.; Shin, J.; Faddegon, B.; Perl, J.

    2012-06-01

    A key task within all Monte Carlo particle transport codes is ‘navigation’, the calculation to determine at each particle step what volume the particle may be leaving and what volume the particle may be entering. Navigation should be optimized to the specific geometry at hand. For patient dose calculation, this geometry generally involves voxelized computed tomography (CT) data. We investigated the efficiency of navigation algorithms on currently available voxel geometry parameterizations in the Monte Carlo simulation package Geant4: G4VPVParameterisation, G4VNestedParameterisation and G4PhantomParameterisation, the last with and without boundary skipping, a method where neighboring voxels with the same Hounsfield unit are combined into one larger voxel. A fourth parameterization approach (MGHParameterization), developed in-house before the latter two parameterizations became available in Geant4, was also included in this study. All simulations were performed using TOPAS, a tool for particle simulations layered on top of Geant4. Runtime comparisons were made on three distinct patient CT data sets: a head and neck, a liver and a prostate patient. We included an additional version of these three patients where all voxels, including the air voxels outside of the patient, were uniformly set to water in the runtime study. The G4VPVParameterisation offers two optimization options. One option has a 60-150 times slower simulation speed. The other is compatible in speed but requires 15-19 times more memory compared to the other parameterizations. We found the average CPU time used for the simulation relative to G4VNestedParameterisation to be 1.014 for G4PhantomParameterisation without boundary skipping and 1.015 for MGHParameterization. The average runtime ratio for G4PhantomParameterisation with and without boundary skipping for our heterogeneous data was equal to 0.97: 1. The calculated dose distributions agreed with the reference distribution for all but the G4

  14. Validation of a virtual source model of medical linac for Monte Carlo dose calculation using multi-threaded Geant4

    Science.gov (United States)

    Aboulbanine, Zakaria; El Khayati, Naïma

    2018-04-01

    The use of phase space in medical linear accelerator Monte Carlo (MC) simulations significantly improves the execution time and leads to results comparable to those obtained from full calculations. The classical representation of phase space stores directly the information of millions of particles, producing bulky files. This paper presents a virtual source model (VSM) based on a reconstruction algorithm, taking as input a compressed file of roughly 800 kb derived from phase space data freely available in the International Atomic Energy Agency (IAEA) database. This VSM includes two main components; primary and scattered particle sources, with a specific reconstruction method developed for each. Energy spectra and other relevant variables were extracted from IAEA phase space and stored in the input description data file for both sources. The VSM was validated for three photon beams: Elekta Precise 6 MV/10 MV and a Varian TrueBeam 6 MV. Extensive calculations in water and comparisons between dose distributions of the VSM and IAEA phase space were performed to estimate the VSM precision. The Geant4 MC toolkit in multi-threaded mode (Geant4-[mt]) was used for fast dose calculations and optimized memory use. Four field configurations were chosen for dose calculation validation to test field size and symmetry effects, , , and for squared fields, and for an asymmetric rectangular field. Good agreement in terms of formalism, for 3%/3 mm and 2%/3 mm criteria, for each evaluated radiation field and photon beam was obtained within a computation time of 60 h on a single WorkStation for a 3 mm voxel matrix. Analyzing the VSM’s precision in high dose gradient regions, using the distance to agreement concept (DTA), showed also satisfactory results. In all investigated cases, the mean DTA was less than 1 mm in build-up and penumbra regions. In regards to calculation efficiency, the event processing speed is six times faster using Geant4-[mt] compared to sequential

  15. Monte carlo simulations of the n_TOF lead spallation target with the Geant4 toolkit: A benchmark study

    Directory of Open Access Journals (Sweden)

    Lerendegui-Marco J.

    2017-01-01

    Full Text Available Monte Carlo (MC simulations are an essential tool to determine fundamental features of a neutron beam, such as the neutron flux or the γ-ray background, that sometimes can not be measured or at least not in every position or energy range. Until recently, the most widely used MC codes in this field had been MCNPX and FLUKA. However, the Geant4 toolkit has also become a competitive code for the transport of neutrons after the development of the native Geant4 format for neutron data libraries, G4NDL. In this context, we present the Geant4 simulations of the neutron spallation target of the n_TOF facility at CERN, done with version 10.1.1 of the toolkit. The first goal was the validation of the intra-nuclear cascade models implemented in the code using, as benchmark, the characteristics of the neutron beam measured at the first experimental area (EAR1, especially the neutron flux and energy distribution, and the time distribution of neutrons of equal kinetic energy, the so-called Resolution Function. The second goal was the development of a Monte Carlo tool aimed to provide useful calculations for both the analysis and planning of the upcoming measurements at the new experimental area (EAR2 of the facility.

  16. Monte carlo simulations of the n_TOF lead spallation target with the Geant4 toolkit: A benchmark study

    Science.gov (United States)

    Lerendegui-Marco, J.; Cortés-Giraldo, M. A.; Guerrero, C.; Quesada, J. M.; Meo, S. Lo; Massimi, C.; Barbagallo, M.; Colonna, N.; Mancussi, D.; Mingrone, F.; Sabaté-Gilarte, M.; Vannini, G.; Vlachoudis, V.; Aberle, O.; Andrzejewski, J.; Audouin, L.; Bacak, M.; Balibrea, J.; Bečvář, F.; Berthoumieux, E.; Billowes, J.; Bosnar, D.; Brown, A.; Caamaño, M.; Calviño, F.; Calviani, M.; Cano-Ott, D.; Cardella, R.; Casanovas, A.; Cerutti, F.; Chen, Y. H.; Chiaveri, E.; Cortés, G.; Cosentino, L.; Damone, L. A.; Diakaki, M.; Domingo-Pardo, C.; Dressler, R.; Dupont, E.; Durán, I.; Fernández-Domínguez, B.; Ferrari, A.; Ferreira, P.; Finocchiaro, P.; Göbel, K.; Gómez-Hornillos, M. B.; García, A. R.; Gawlik, A.; Gilardoni, S.; Glodariu, T.; Gonçalves, I. F.; González, E.; Griesmayer, E.; Gunsing, F.; Harada, H.; Heinitz, S.; Heyse, J.; Jenkins, D. G.; Jericha, E.; Käppeler, F.; Kadi, Y.; Kalamara, A.; Kavrigin, P.; Kimura, A.; Kivel, N.; Kokkoris, M.; Krtička, M.; Kurtulgil, D.; Leal-Cidoncha, E.; Lederer, C.; Leeb, H.; Lonsdale, S. J.; Macina, D.; Marganiec, J.; Martínez, T.; Masi, A.; Mastinu, P.; Mastromarco, M.; Maugeri, E. A.; Mazzone, A.; Mendoza, E.; Mengoni, A.; Milazzo, P. M.; Musumarra, A.; Negret, A.; Nolte, R.; Oprea, A.; Patronis, N.; Pavlik, A.; Perkowski, J.; Porras, I.; Praena, J.; Radeck, D.; Rauscher, T.; Reifarth, R.; Rout, P. C.; Rubbia, C.; Ryan, J. A.; Saxena, A.; Schillebeeckx, P.; Schumann, D.; Smith, A. G.; Sosnin, N. V.; Stamatopoulos, A.; Tagliente, G.; Tain, J. L.; Tarifeño-Saldivia, A.; Tassan-Got, L.; Valenta, S.; Variale, V.; Vaz, P.; Ventura, A.; Vlastou, R.; Wallner, A.; Warren, S.; Woods, P. J.; Wright, T.; Žugec, P.

    2017-09-01

    Monte Carlo (MC) simulations are an essential tool to determine fundamental features of a neutron beam, such as the neutron flux or the γ-ray background, that sometimes can not be measured or at least not in every position or energy range. Until recently, the most widely used MC codes in this field had been MCNPX and FLUKA. However, the Geant4 toolkit has also become a competitive code for the transport of neutrons after the development of the native Geant4 format for neutron data libraries, G4NDL. In this context, we present the Geant4 simulations of the neutron spallation target of the n_TOF facility at CERN, done with version 10.1.1 of the toolkit. The first goal was the validation of the intra-nuclear cascade models implemented in the code using, as benchmark, the characteristics of the neutron beam measured at the first experimental area (EAR1), especially the neutron flux and energy distribution, and the time distribution of neutrons of equal kinetic energy, the so-called Resolution Function. The second goal was the development of a Monte Carlo tool aimed to provide useful calculations for both the analysis and planning of the upcoming measurements at the new experimental area (EAR2) of the facility.

  17. Designing a new type of neutron detector for neutron and gamma-ray discrimination via GEANT4

    International Nuclear Information System (INIS)

    Shan, Qing; Chu, Shengnan; Ling, Yongsheng; Cai, Pingkun; Jia, Wenbao

    2016-01-01

    Design of a new type of neutron detector, consisting of a fast neutron converter, plastic scintillator, and Cherenkov detector, to discriminate 14-MeV fast neutrons and gamma rays in a pulsed n–γ mixed field and monitor their neutron fluxes is reported in this study. Both neutrons and gamma rays can produce fluorescence in the scintillator when they are incident on the detector. However, only the secondary charged particles of the gamma rays can produce Cherenkov light in the Cherenkov detector. The neutron and gamma-ray fluxes can be calculated by measuring the fluorescence and Cherenkov light. The GEANT4 Monte Carlo simulation toolkit is used to simulate the whole process occurring in the detector, whose optimum parameters are known. Analysis of the simulation results leads to a calculation method of neutron flux. This method is verified by calculating the neutron fluxes using pulsed n–γ mixed fields with different n/γ ratios, and the results show that the relative errors of all calculations are <5%. - Highlights: • A neutron detector is developed to discriminate 14-MeV fast neutrons and gamma rays. • The GEANT4 is used to optimize the parameters of the detector. • A calculation method of neutron flux is established through the simulation. • Several n/γ mixture fields are simulated to validate of the calculation method.

  18. Use of SRIM and Garfield with Geant4 for the characterization of a hybrid 10B/3He neutron detector

    Science.gov (United States)

    van der Ende, B. M.; Rand, E. T.; Erlandson, A.; Li, L.

    2018-06-01

    This paper describes a method for more complete neutron detector characterization using Geant4's Monte Carlo methods for characterizing overall detector response rate and Garfield interfaced with SRIM for the simulation of the detector's raw pulses, as applied to a hybrid 10B/3He detector. The Geant4 models characterizing the detector's interaction with a 252Cf point source and parallel beams of mono-energetic neutrons (assuming ISO 8529 reference energy values) compare and agree well with calibrated 252Cf measurements to within 6.4%. Validated Geant4 model outputs serve as input to Garfield+SRIM calculations to provide meaningful pulse height spectra. Modifications to Garfield for this work were necessary to account for simultaneous tracking of electrons resulting from proton and triton reaction products from a single 3He neutron capture event, and it was further necessary to interface Garfield with the energy loss, range, and straggling calculations provided by SRIM. Individual raw pulses generated by Garfield+SRIM are also observed to agree well with experimentally measured raw pulses from the detector.

  19. BRDF profile of Tyvek and its implementation in the Geant4 simulation toolkit.

    Science.gov (United States)

    Nozka, Libor; Pech, Miroslav; Hiklova, Helena; Mandat, Dusan; Hrabovsky, Miroslav; Schovanek, Petr; Palatka, Miroslav

    2011-02-28

    Diffuse and specular characteristics of the Tyvek 1025-BL material are reported with respect to their implementation in the Geant4 Monte Carlo simulation toolkit. This toolkit incorporates the UNIFIED model. Coefficients defined by the UNIFIED model were calculated from the bidirectional reflectance distribution function (BRDF) profiles measured with a scatterometer for several angles of incidence. Results were amended with profile measurements made by a profilometer.

  20. Validation of GEANT4 Monte Carlo Models with a Highly Granular Scintillator-Steel Hadron Calorimeter

    CERN Document Server

    Adloff, C.; Blaising, J.J.; Drancourt, C.; Espargiliere, A.; Gaglione, R.; Geffroy, N.; Karyotakis, Y.; Prast, J.; Vouters, G.; Francis, K.; Repond, J.; Schlereth, J.; Smith, J.; Xia, L.; Baldolemar, E.; Li, J.; Park, S.T.; Sosebee, M.; White, A.P.; Yu, J.; Buanes, T.; Eigen, G.; Mikami, Y.; Watson, N.K.; Mavromanolakis, G.; Thomson, M.A.; Ward, D.R.; Yan, W.; Benchekroun, D.; Hoummada, A.; Khoulaki, Y.; Apostolakis, J.; Dotti, A.; Folger, G.; Ivantchenko, V.; Uzhinskiy, V.; Benyamna, M.; Cârloganu, C.; Fehr, F.; Gay, P.; Manen, S.; Royer, L.; Blazey, G.C.; Dyshkant, A.; Lima, J.G.R.; Zutshi, V.; Hostachy, J.Y.; Morin, L.; Cornett, U.; David, D.; Falley, G.; Gadow, K.; Gottlicher, P.; Gunter, C.; Hermberg, B.; Karstensen, S.; Krivan, F.; Lucaci-Timoce, A.I.; Lu, S.; Lutz, B.; Morozov, S.; Morgunov, V.; Reinecke, M.; Sefkow, F.; Smirnov, P.; Terwort, M.; Vargas-Trevino, A.; Feege, N.; Garutti, E.; Marchesini, I.; Ramilli, M.; Eckert, P.; Harion, T.; Kaplan, A.; Schultz-Coulon, H.Ch.; Shen, W.; Stamen, R.; Bilki, B.; Norbeck, E.; Onel, Y.; Wilson, G.W.; Kawagoe, K.; Dauncey, P.D.; Magnan, A.M.; Bartsch, V.; Wing, M.; Salvatore, F.; Alamillo, E.Calvo; Fouz, M.C.; Puerta-Pelayo, J.; Bobchenko, B.; Chadeeva, M.; Danilov, M.; Epifantsev, A.; Markin, O.; Mizuk, R.; Novikov, E.; Popov, V.; Rusinov, V.; Tarkovsky, E.; Kirikova, N.; Kozlov, V.; Smirnov, P.; Soloviev, Y.; Buzhan, P.; Ilyin, A.; Kantserov, V.; Kaplin, V.; Karakash, A.; Popova, E.; Tikhomirov, V.; Kiesling, C.; Seidel, K.; Simon, F.; Soldner, C.; Szalay, M.; Tesar, M.; Weuste, L.; Amjad, M.S.; Bonis, J.; Callier, S.; Conforti di Lorenzo, S.; Cornebise, P.; Doublet, Ph.; Dulucq, F.; Fleury, J.; Frisson, T.; van der Kolk, N.; Li, H.; Martin-Chassard, G.; Richard, F.; de la Taille, Ch.; Poschl, R.; Raux, L.; Rouene, J.; Seguin-Moreau, N.; Anduze, M.; Boudry, V.; Brient, J-C.; Jeans, D.; Mora de Freitas, P.; Musat, G.; Reinhard, M.; Ruan, M.; Videau, H.; Bulanek, B.; Zacek, J.; Cvach, J.; Gallus, P.; Havranek, M.; Janata, M.; Kvasnicka, J.; Lednicky, D.; Marcisovsky, M.; Polak, I.; Popule, J.; Tomasek, L.; Tomasek, M.; Ruzicka, P.; Sicho, P.; Smolik, J.; Vrba, V.; Zalesak, J.; Belhorma, B.; Ghazlane, H.; Takeshita, T.; Uozumi, S.; Gotze, M.; Hartbrich, O.; Sauer, J.; Weber, S.; Zeitnitz, C.

    2013-01-01

    Calorimeters with a high granularity are a fundamental requirement of the Particle Flow paradigm. This paper focuses on the prototype of a hadron calorimeter with analog readout, consisting of thirty-eight scintillator layers alternating with steel absorber planes. The scintillator plates are finely segmented into tiles individually read out via Silicon Photomultipliers. The presented results are based on data collected with pion beams in the energy range from 8GeV to 100GeV. The fine segmentation of the sensitive layers and the high sampling frequency allow for an excellent reconstruction of the spatial development of hadronic showers. A comparison between data and Monte Carlo simulations is presented, concerning both the longitudinal and lateral development of hadronic showers and the global response of the calorimeter. The performance of several GEANT4 physics lists with respect to these observables is evaluated.

  1. Geant4 simulation of gamma conversion to muon pair for dark matter searches

    CERN Document Server

    Sokolov, Anton

    2017-01-01

    There is a direct evidence from different astronomical observations and CMB spectrum that 26% of the visible part of the Universe consists of so-called dark matter. There are many models explaining the phenomenon of dark matter, however none of them has been confirmed experimentally. It justifies the further searches for the dark matter that involve more and more various experiments, such as, for instance, SHiP experiment [1] at CERN or LDMX project [2] at SLAC. LDMX (Light Dark Matter eXperiment) is an electron fixedtarget missing momentum search for light dark matter. The main process that LDMX looks for is dark bremsstrahlung (i.e. emitting a light dark matter particle) by the several GeV electrons scattered off the target. This process is contaminated by the background of ordinary bremsstrahlung, that consists of many different processes which can be accounted for and vetoed by various counters. The experiment designs are studied with the Geant4 toolkit. Recently, one of the important background pro...

  2. Particle physics software aids space and medicine

    CERN Document Server

    Pia, M G

    2002-01-01

    Geant4 is a showcase example of technology transfer from particle physics to other fields such as space and medical science. Geant4 was first used for space applications by ESA in 1999, when ESA and NASA each launched an X-ray telescope. Geant4's extended set of physics models, which handle both electromagnetic and hadronic interactions, can be used to address a range of medical applications from conventional photon-beam radiotherapy to brachytherapy (using radioactive sources), hadron therapy and boron neutron capture therapy. The tools for describing geometries, materials and electromagnetic fields can precisely model diverse real-life configurations.

  3. A COMPUTER CLUSTER SYSTEM FOR PSEUDO-PARALLEL EXECUTION OF GEANT4 SERIAL APPLICATION

    Directory of Open Access Journals (Sweden)

    Memmo Federici

    2013-12-01

    Full Text Available Simulation of the interactions between particles and matter in studies for developing X-rays detectors generally requires very long calculation times (up to several days or weeks. These times are often a serious limitation for the success of the simulations and for the accuracy of the simulated models. One of the tools used by the scientific community to perform these simulations is Geant4 (Geometry And Tracking [2, 3]. On the best of experience in the design of the AVES cluster computing system, Federici et al. [1], the IAPS (Istituto di Astrofisica e Planetologia Spaziali INAF laboratories were able to develop a cluster computer system dedicated to Geant 4. The Cluster is easy to use and easily expandable, and thanks to the design criteria adopted it achieves an excellent compromise between performance and cost. The management software developed for the Cluster splits the single instance of simulation on the cores available, allowing the use of software written for serial computation to reach a computing speed similar to that obtainable from a native parallel software. The simulations carried out on the Cluster showed an increase in execution time by a factor of 20 to 60 compared to the times obtained with the use of a single PC of medium quality.

  4. Progress and Validation of Geant4 Based Radioactive Decay Simulation Using the Examples of Simbol-X and IXO

    CERN Document Server

    Hauf, S; Pia, M G; Bell, Z; Briel, U; Chipaux, R; Hoffmann, D H H; Kendziorra, E; Laurent, P; Strüder, L; Tenzer, C; Weidenspointer, G; Zoglauer, A

    2009-01-01

    The anticipated high sensitivity and the science goals of the next generation X-ray space missions, like the International X-ray Observatory or Simbol-X, rely on a low instrumental background, which in turn requires optimized shielding concepts. We present Geant4 based simulation results on the IXO Wide Field Imager cosmic ray proton induced background in comparison with previous results obtained for the Simbol-X LED and HED focal plane detectors. Our results show that an improvement in mean differential background flux compared to actually operating X-ray observatories may be feasible with detectors based on DEPFET technology. In addition we present preliminary results concerning the validation of Geant4 based radioactive decay simulation in space applications as a part of the Nano5 project.

  5. Nuclear fragmentation reactions in extended media studied with Geant4 toolkit

    Energy Technology Data Exchange (ETDEWEB)

    Pshenichnov, Igor, E-mail: pshenich@fias.uni-frankfurt.d [Frankfurt Institute for Advanced Studies, J.-W. Goethe University, 60438 Frankfurt am Main (Germany); Institute for Nuclear Research, Russian Academy of Science, 117312 Moscow (Russian Federation); Botvina, Alexander [Frankfurt Institute for Advanced Studies, J.-W. Goethe University, 60438 Frankfurt am Main (Germany); Institute for Nuclear Research, Russian Academy of Science, 117312 Moscow (Russian Federation); Mishustin, Igor [Frankfurt Institute for Advanced Studies, J.-W. Goethe University, 60438 Frankfurt am Main (Germany); Kurchatov Institute, Russian Research Center, 123182 Moscow (Russian Federation); Greiner, Walter [Frankfurt Institute for Advanced Studies, J.-W. Goethe University, 60438 Frankfurt am Main (Germany)

    2010-03-15

    It is well-known from numerous experiments that nuclear multifragmentation is a dominating mechanism for production of intermediate mass fragments in nucleus-nucleus collisions at energies above 100AMeV. In this paper we investigate the validity and performance of the Fermi break-up model and the statistical multifragmentation model implemented as parts of the Geant4 toolkit. We study the impact of violent nuclear disintegration reactions on the depth-dose profiles and yields of secondary fragments for beams of light and medium-weight nuclei propagating in extended media. Implications for ion-beam cancer therapy and shielding from cosmic radiation are discussed.

  6. Nuclear fragmentation reactions in extended media studied with Geant4 toolkit

    International Nuclear Information System (INIS)

    Pshenichnov, Igor; Botvina, Alexander; Mishustin, Igor; Greiner, Walter

    2010-01-01

    It is well-known from numerous experiments that nuclear multifragmentation is a dominating mechanism for production of intermediate mass fragments in nucleus-nucleus collisions at energies above 100AMeV. In this paper we investigate the validity and performance of the Fermi break-up model and the statistical multifragmentation model implemented as parts of the Geant4 toolkit. We study the impact of violent nuclear disintegration reactions on the depth-dose profiles and yields of secondary fragments for beams of light and medium-weight nuclei propagating in extended media. Implications for ion-beam cancer therapy and shielding from cosmic radiation are discussed.

  7. Nuclear spectroscopy with Geant4: Proton and neutron emission & radioactivity

    Science.gov (United States)

    Sarmiento, L. G.; Rudolph, D.

    2016-07-01

    With the aid of a novel combination of existing equipment - JYFLTRAP and the TASISpec decay station - it is possible to perform very clean quantum-state selective, high-resolution particle-γ decay spectroscopy. We intend to study the determination of the branching ratio of the ℓ = 9 proton emission from the Iπ = 19/2-, 3174-keV isomer in the N = Z - 1 nucleus 53Co. The study aims to initiate a series of similar experiments along the proton dripline, thereby providing unique insights into "open quantum systems". The technique has been pioneered in case studies using SHIPTRAP and TASISpec at GSI. Newly available radioactive decay modes in Geant4 simulations are going to corroborate the anticipated experimental results.

  8. Geant4.10 simulation of geometric model for metaphase chromosome

    Energy Technology Data Exchange (ETDEWEB)

    Rafat-Motavalli, L., E-mail: rafat@um.ac.ir; Miri-Hakimabad, H.; Bakhtiyari, E.

    2016-04-01

    In this paper, a geometric model of metaphase chromosome is explained. The model is constructed according to the packing ratio and dimension of the structure from nucleosome up to chromosome. A B-DNA base pair is used to construct 200 base pairs of nucleosomes. Each chromatin fiber loop, which is the unit of repeat, has 49,200 bp. This geometry is entered in Geant4.10 Monte Carlo simulation toolkit and can be extended to the whole metaphase chromosomes and any application in which a DNA geometrical model is needed. The chromosome base pairs, chromosome length, and relative length of chromosomes are calculated. The calculated relative length is compared to the relative length of human chromosomes.

  9. Geant4.10 simulation of geometric model for metaphase chromosome

    International Nuclear Information System (INIS)

    Rafat-Motavalli, L.; Miri-Hakimabad, H.; Bakhtiyari, E.

    2016-01-01

    In this paper, a geometric model of metaphase chromosome is explained. The model is constructed according to the packing ratio and dimension of the structure from nucleosome up to chromosome. A B-DNA base pair is used to construct 200 base pairs of nucleosomes. Each chromatin fiber loop, which is the unit of repeat, has 49,200 bp. This geometry is entered in Geant4.10 Monte Carlo simulation toolkit and can be extended to the whole metaphase chromosomes and any application in which a DNA geometrical model is needed. The chromosome base pairs, chromosome length, and relative length of chromosomes are calculated. The calculated relative length is compared to the relative length of human chromosomes.

  10. Influence of thyroid volume reduction on absorbed dose in "1"3"1I therapy studied by using Geant4 Monte Carlo simulation

    International Nuclear Information System (INIS)

    Rahman, Ziaur; Arshed, Waheed; Ahmed, Waheed; Mirza, Sikander M.; Mirza, Nasir M.

    2014-01-01

    A simulation study has been performed to quantify the effect of volume reduction on the thyroid absorbed dose per decay and to investigate the variation of energy deposition per decay due to β- and γ-activity of "1"3"1I with volume/mass of thyroid, for water, ICRP- and ICRU-soft tissue taken as thyroid material. A Monte Carlo model of the thyroid, in the Geant4 radiation transport simulation toolkit was constructed to compute the β- and γ-absorbed dose in the simulated thyroid phantom for various values of its volume. The effect of the size and shape of the thyroid on energy deposition per decay has also been studied by using spherical, ellipsoidal and cylindrical models for the thyroid and varying its volume in 1-25 cm"3 range. The relative differences of Geant4 results for different models with each other and MCNP results lie well below 1.870%. The maximum relative difference among the Geant4 estimated results for water with ICRP and ICRU soft tissues is not more than 0.225%. S-values for ellipsoidal, spherical and cylindrical thyroid models were estimated and the relative difference with published results lies within 3.095%. The absorbed fraction values for beta particles show a good agreement with published values within 2.105% deviation. The Geant4 based simulation results of absorbed fractions for gammas again show a good agreement with the corresponding MCNP and EGS4 results (± 6.667%) but have 29.032% higher values than that of MIRD calculated values. Consistent with previous studies, the reduction of the thyroid volume is found to have a substantial effect on the absorbed dose. Geant4 simulations confirm dose dependence on the volume/mass of thyroid in agreement with MCNP and EGS4 computed values but are substantially different from MIRD8 data. Therefore, inclusion of size/mass dependence is indicated for "1"3"1I radiotherapy of the thyroid. (authors)

  11. A polygon-surface reference Korean male phantom (PSRK-Man) and its direct implementation in Geant4 Monte Carlo simulation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chan Hyeong; Jeong, Jong Hwi [Department of Nuclear Engineering, Hanyang University, 17 Haengdang-dong, Seongdong-gu, Seoul 133-791 (Korea, Republic of); Bolch, Wesley E [Department of Nuclear and Radiological Engineering, University of Florida, Gainesville, FL 32611 (United States); Cho, Kun-Woo [Korea Institute of Nuclear Safety, 19 Guseong-dong, Yuseong-gu, Daejeon 305-600 (Korea, Republic of); Hwang, Sung Bae, E-mail: chkim@hanyang.ac.kr [Department of Physical Therapy, Kyungbuk College, Hyucheon 2-dong, Yeongju-si, Gyeongbuk 750-712 (Korea, Republic of)

    2011-05-21

    Even though the hybrid phantom embodies both the anatomic reality of voxel phantoms and the deformability of stylized phantoms, it must be voxelized to be used in a Monte Carlo code for dose calculation or some imaging simulation, which incurs the inherent limitations of voxel phantoms. In the present study, a voxel phantom named VKH-Man (Visible Korean Human-Man), was converted to a polygon-surface phantom (PSRK-Man, Polygon-Surface Reference Korean-Man), which was then adjusted to the Reference Korean data. Subsequently, the PSRK-Man polygon phantom was directly, without any voxelization process, implemented in the Geant4 Monte Carlo code for dose calculations. The calculated dose values and computation time were then compared with those of HDRK-Man (High Definition Reference Korean-Man), a corresponding voxel phantom adjusted to the same Reference Korean data from the same VKH-Man voxel phantom. Our results showed that the calculated dose values of the PSRK-Man surface phantom agreed well with those of the HDRK-Man voxel phantom. The calculation speed for the PSRK-Man polygon phantom though was 70-150 times slower than that of the HDRK-Man voxel phantom; that speed, however, could be acceptable in some applications, in that direct use of the surface phantom PSRK-Man in Geant4 does not require a separate voxelization process. Computing speed can be enhanced, in future, either by optimizing the Monte Carlo transport kernel for the polygon surfaces or by using modern computing technologies such as grid computing and general-purpose computing on graphics processing units programming.

  12. A polygon-surface reference Korean male phantom (PSRK-Man) and its direct implementation in Geant4 Monte Carlo simulation

    International Nuclear Information System (INIS)

    Kim, Chan Hyeong; Jeong, Jong Hwi; Bolch, Wesley E; Cho, Kun-Woo; Hwang, Sung Bae

    2011-01-01

    Even though the hybrid phantom embodies both the anatomic reality of voxel phantoms and the deformability of stylized phantoms, it must be voxelized to be used in a Monte Carlo code for dose calculation or some imaging simulation, which incurs the inherent limitations of voxel phantoms. In the present study, a voxel phantom named VKH-Man (Visible Korean Human-Man), was converted to a polygon-surface phantom (PSRK-Man, Polygon-Surface Reference Korean-Man), which was then adjusted to the Reference Korean data. Subsequently, the PSRK-Man polygon phantom was directly, without any voxelization process, implemented in the Geant4 Monte Carlo code for dose calculations. The calculated dose values and computation time were then compared with those of HDRK-Man (High Definition Reference Korean-Man), a corresponding voxel phantom adjusted to the same Reference Korean data from the same VKH-Man voxel phantom. Our results showed that the calculated dose values of the PSRK-Man surface phantom agreed well with those of the HDRK-Man voxel phantom. The calculation speed for the PSRK-Man polygon phantom though was 70-150 times slower than that of the HDRK-Man voxel phantom; that speed, however, could be acceptable in some applications, in that direct use of the surface phantom PSRK-Man in Geant4 does not require a separate voxelization process. Computing speed can be enhanced, in future, either by optimizing the Monte Carlo transport kernel for the polygon surfaces or by using modern computing technologies such as grid computing and general-purpose computing on graphics processing units programming.

  13. Monte Carlo simulation and scatter correction of the GE Advance PET scanner with SimSET and Geant4

    International Nuclear Information System (INIS)

    Barret, Olivier; Carpenter, T Adrian; Clark, John C; Ansorge, Richard E; Fryer, Tim D

    2005-01-01

    For Monte Carlo simulations to be used as an alternative solution to perform scatter correction, accurate modelling of the scanner as well as speed is paramount. General-purpose Monte Carlo packages (Geant4, EGS, MCNP) allow a detailed description of the scanner but are not efficient at simulating voxel-based geometries (patient images). On the other hand, dedicated codes (SimSET, PETSIM) will perform well for voxel-based objects but will be poor in their capacity of simulating complex geometries such as a PET scanner. The approach adopted in this work was to couple a dedicated code (SimSET) with a general-purpose package (Geant4) to have the efficiency of the former and the capabilities of the latter. The combined SimSET+Geant4 code (SimG4) was assessed on the GE Advance PET scanner and compared to the use of SimSET only. A better description of the resolution and sensitivity of the scanner and of the scatter fraction was obtained with SimG4. The accuracy of scatter correction performed with SimG4 and SimSET was also assessed from data acquired with the 20 cm NEMA phantom. SimG4 was found to outperform SimSET and to give slightly better results than the GE scatter correction methods installed on the Advance scanner (curve fitting and scatter modelling for the 300-650 keV and 375-650 keV energy windows, respectively). In the presence of a hot source close to the edge of the field of view (as found in oxygen scans), the GE curve-fitting method was found to fail whereas SimG4 maintained its performance

  14. Validation of the coupling of mesh models to GEANT4 Monte Carlo code for simulation of internal sources of photons

    International Nuclear Information System (INIS)

    Caribe, Paulo Rauli Rafeson Vasconcelos; Cassola, Vagner Ferreira; Kramer, Richard; Khoury, Helen Jamil

    2013-01-01

    The use of three-dimensional models described by polygonal meshes in numerical dosimetry enables more accurate modeling of complex objects than the use of simple solid. The objectives of this work were validate the coupling of mesh models to the Monte Carlo code GEANT4 and evaluate the influence of the number of vertices in the simulations to obtain absorbed fractions of energy (AFEs). Validation of the coupling was performed to internal sources of photons with energies between 10 keV and 1 MeV for spherical geometries described by the GEANT4 and three-dimensional models with different number of vertices and triangular or quadrilateral faces modeled using Blender program. As a result it was found that there were no significant differences between AFEs for objects described by mesh models and objects described using solid volumes of GEANT4. Since that maintained the shape and the volume the decrease in the number of vertices to describe an object does not influence so meant dosimetric data, but significantly decreases the time required to achieve the dosimetric calculations, especially for energies less than 100 keV

  15. CLIC Detector Concepts as described in the CDR: Differences between the GEANT4 and Engineering Models

    CERN Document Server

    Elsener, K; Schlatter, D; Siegrist, N

    2011-01-01

    The CLIC_ILD and CLIC_SiD detector concepts as used for the CDR Vol. 2 in 2011 exist both in GEANT4 simulation models and in engineering layout drawings. At this early stage of a conceptual design, there are inevitably differences between these models, which are described in this note.

  16. Geant4 simulation of a 3D high resolution gamma camera

    International Nuclear Information System (INIS)

    Akhdar, H.; Kezzar, K.; Aksouh, F.; Assemi, N.; AlGhamdi, S.; AlGarawi, M.; Gerl, J.

    2015-01-01

    The aim of this work is to develop a 3D gamma camera with high position resolution and sensitivity relying on both distance/absorption and Compton scattering techniques and without using any passive collimation. The proposed gamma camera is simulated in order to predict its performance using the full benefit of Geant4 features that allow the construction of the needed geometry of the detectors, have full control of the incident gamma particles and study the response of the detector in order to test the suggested geometries. Three different geometries are simulated and each configuration is tested with three different scintillation materials (LaBr3, LYSO and CeBr3)

  17. Nuclear spectroscopy with Geant4: Proton and neutron emission & radioactivity

    Energy Technology Data Exchange (ETDEWEB)

    Sarmiento, L. G., E-mail: Luis.Sarmiento@nuclear.lu.se; Rudolph, D. [Department of Physics, Lund University, 22100 Lund (Sweden)

    2016-07-07

    With the aid of a novel combination of existing equipment – JYFLTRAP and the TASISpec decay station – it is possible to perform very clean quantum-state selective, high-resolution particle-γ decay spectroscopy. We intend to study the determination of the branching ratio of the ℓ = 9 proton emission from the I{sup π} = 19/2{sup −}, 3174-keV isomer in the N = Z − 1 nucleus {sup 53}Co. The study aims to initiate a series of similar experiments along the proton dripline, thereby providing unique insights into “open quantum systems”. The technique has been pioneered in case studies using SHIPTRAP and TASISpec at GSI. Newly available radioactive decay modes in Geant4 simulations are going to corroborate the anticipated experimental results.

  18. New Standard Evaluated Neutron Cross Section Libraries for the GEANT4 Code and First Verification

    CERN Document Server

    Mendoza, Emilio; Koi, Tatsumi; Guerrero, Carlos

    2014-01-01

    The Monte Carlo simulation of the interaction of neutrons with matter relies on evaluated nuclear data libraries and models. The evaluated libraries are compilations of measured physical parameters (such as cross sections) combined with predictions of nuclear model calculations which have been adjusted to reproduce the experimental data. The results obtained from the simulations depend largely on the accuracy of the underlying nuclear data used, and thus it is important to have access to the nuclear data libraries available, either of general use or compiled for specific applications, and to perform exhaustive validations which cover the wide scope of application of the simulation code. In this paper we describe the work performed in order to extend the capabilities of the GEANT4 toolkit for the simulation of the interaction of neutrons with matter at neutron energies up to 20 MeV and a first verification of the results obtained. Such a work is of relevance for applications as diverse as the simulation of a n...

  19. Inter-comparison of Dose Distributions Calculated by FLUKA, GEANT4, MCNP, and PHITS for Proton Therapy

    Science.gov (United States)

    Yang, Zi-Yi; Tsai, Pi-En; Lee, Shao-Chun; Liu, Yen-Chiang; Chen, Chin-Cheng; Sato, Tatsuhiko; Sheu, Rong-Jiun

    2017-09-01

    The dose distributions from proton pencil beam scanning were calculated by FLUKA, GEANT4, MCNP, and PHITS, in order to investigate their applicability in proton radiotherapy. The first studied case was the integrated depth dose curves (IDDCs), respectively from a 100 and a 226-MeV proton pencil beam impinging a water phantom. The calculated IDDCs agree with each other as long as each code employs 75 eV for the ionization potential of water. The second case considered a similar condition of the first case but with proton energies in a Gaussian distribution. The comparison to the measurement indicates the inter-code differences might not only due to different stopping power but also the nuclear physics models. How the physics parameter setting affect the computation time was also discussed. In the third case, the applicability of each code for pencil beam scanning was confirmed by delivering a uniform volumetric dose distribution based on the treatment plan, and the results showed general agreement between each codes, the treatment plan, and the measurement, except that some deviations were found in the penumbra region. This study has demonstrated that the selected codes are all capable of performing dose calculations for therapeutic scanning proton beams with proper physics settings.

  20. Investigation of radial dose effect on single event upset cross-section due to heavy ions using GEANT4

    International Nuclear Information System (INIS)

    Boorboor, S.; Feghhi, S.A.H.; Jafari, H.

    2015-01-01

    The heavy ions are the main cause to produce single event upset (SEU) damage on electronic devices since they are high LET radiations. The dimension of electronic components in new technology, arise a challenge in radiation effect estimations. Accurate investigations require fully considering the ion track in energy deposition as a radial dose distribution. In this work, the distribution of delta rays as well as LET have been calculated to determine ionization structure around ion track by a Monte Carlo code, GEANT4. The radial dose of several heavy ions with different energy in silicon was investigated and compared with the works by other authors in this field. The results showed that heavy ions with identical LET can have different SEU cross-section in silicon transistors. As a demonstrative example, according to our results, the error probability for 4.8 GeV iron was 8 times greater than that for 15 MeV carbon ions, in transistors with new process technology which have small dimension and low critical charges. Our results show that considering radial dose distribution considerably improves the accuracy of the SEU cross-section estimation in electronic devices especially for new technologies. - Highlights: • The single event upset is produced by heavy ions interaction on electronic devices. • The radial dose of several heavy ions in silicon was calculated by GEANT4. • Heavy ions with identical LET had different SEU cross-section in silicon transistors. • Low dimension and critical charge devices were more sensitive to radial dose effect

  1. A Preliminary Study on Time Projection Chamber Simulation for Fission Cross Section Measurements with Geant4

    International Nuclear Information System (INIS)

    Kim, Jong Woon; Lee, Youngouk; Kim, Jae Cheon

    2014-01-01

    We present the details of the TPC simulation with Geant4 and show the results. TPC can provide more information than a fission chamber in that it is possible to distinguish different particle types. Simulations are conducted for uranium and plutonium targets with 20MeV neutrons. The simulation results are compared with the reference and show reasonable results. This is the first phase of study for realizing a TPC in the NFS at RAON, and we have more work to do, such as applying an electric field, signal processing in the simulation, and manufacturing of a TPC. The standard in fission cross section measurement is a fission chamber. It is basically just two parallel plates separated by a few centimeters of gas. A power supply connected to the plates sets up a moderate electric field. The target is deposited onto one of the plates. When fission occurs, the fragments ionize the gas, and the electric field causes the produced electrons to drift to the opposite plate, which records the total energy deposited in the chamber. A Time Projection Chamber (TPC) is a gas ionization detector similar to a fission chamber. However, it can measure the charged particle trajectories in the active volume in three dimensions by adding several readouts on the pad plane (fission chamber has only one readout one a pad plane). The specific ionization for each particle track enables the TPC to distinguish different particle types. A TPC will be used for fission cross section measurements in the Neutron Science Facility (NSF) at RAON. As a preliminary study, we present details of TPC simulation with Geant4 and discuss the results

  2. Physical models, cross sections, and numerical approximations used in MCNP and GEANT4 Monte Carlo codes for photon and electron absorbed fraction calculation.

    Science.gov (United States)

    Yoriyaz, Hélio; Moralles, Maurício; Siqueira, Paulo de Tarso Dalledone; Guimarães, Carla da Costa; Cintra, Felipe Belonsi; dos Santos, Adimir

    2009-11-01

    Radiopharmaceutical applications in nuclear medicine require a detailed dosimetry estimate of the radiation energy delivered to the human tissues. Over the past years, several publications addressed the problem of internal dose estimate in volumes of several sizes considering photon and electron sources. Most of them used Monte Carlo radiation transport codes. Despite the widespread use of these codes due to the variety of resources and potentials they offered to carry out dose calculations, several aspects like physical models, cross sections, and numerical approximations used in the simulations still remain an object of study. Accurate dose estimate depends on the correct selection of a set of simulation options that should be carefully chosen. This article presents an analysis of several simulation options provided by two of the most used codes worldwide: MCNP and GEANT4. For this purpose, comparisons of absorbed fraction estimates obtained with different physical models, cross sections, and numerical approximations are presented for spheres of several sizes and composed as five different biological tissues. Considerable discrepancies have been found in some cases not only between the different codes but also between different cross sections and algorithms in the same code. Maximum differences found between the two codes are 5.0% and 10%, respectively, for photons and electrons. Even for simple problems as spheres and uniform radiation sources, the set of parameters chosen by any Monte Carlo code significantly affects the final results of a simulation, demonstrating the importance of the correct choice of parameters in the simulation.

  3. SU-E-T-427: Feasibility Study for Evaluation of IMRT Dose Distribution Using Geant4-Based Automated Algorithms

    International Nuclear Information System (INIS)

    Choi, H; Shin, W; Testa, M; Min, C; Kim, J

    2015-01-01

    Purpose: For intensity-modulated radiation therapy (IMRT) treatment planning validation using Monte Carlo (MC) simulations, a precise and automated procedure is necessary to evaluate the patient dose distribution. The aim of this study is to develop an automated algorithm for IMRT simulations using DICOM files and to evaluate the patient dose based on 4D simulation using the Geant4 MC toolkit. Methods: The head of a clinical linac (Varian Clinac 2300 IX) was modeled in Geant4 along with particular components such as the flattening filter and the multi-leaf collimator (MLC). Patient information and the position of the MLC were imported from the DICOM-RT interface. For each position of the MLC, a step- and-shoot technique was adopted. PDDs and lateral profiles were simulated in a water phantom (50×50×40 cm 3 ) and compared to measurement data. We used a lung phantom and MC-dose calculations were compared to the clinical treatment planning used at the Seoul National University Hospital. Results: In order to reproduce the measurement data, we tuned three free parameters: mean and standard deviation of the primary electron beam energy and the beam spot size. These parameters for 6 MV were found to be 5.6 MeV, 0.2378 MeV and 1 mm FWHM respectively. The average dose difference between measurements and simulations was less than 2% for PDDs and radial profiles. The lung phantom study showed fairly good agreement between MC and planning dose despite some unavoidable statistical fluctuation. Conclusion: The current feasibility study using the lung phantom shows the potential for IMRT dose validation using 4D MC simulations using Geant4 tool kits. This research was supported by Korea Institute of Nuclear safety and Development of Measurement Standards for Medical Radiation funded by Korea research Institute of Standards and Science. (KRISS-2015-15011032)

  4. Calculation of self–shielding factor for neutron activation experiments using GEANT4 and MCNP

    Energy Technology Data Exchange (ETDEWEB)

    Romero–Barrientos, Jaime, E-mail: jaromero@ing.uchile.cl [Comisión Chilena de Energía Nuclear, Nueva Bilbao 12501, Las Condes, Santiago (Chile); Universidad de Chile, DFI, Facultad de Ciencias Físicas Y Matemáticas, Avenida Blanco Encalada 2008, Santiago (Chile); Molina, F. [Comisión Chilena de Energía Nuclear, Nueva Bilbao 12501, Las Condes, Santiago (Chile); Aguilera, Pablo [Comisión Chilena de Energía Nuclear, Nueva Bilbao 12501, Las Condes, Santiago (Chile); Universidad de Chile, Depto. de Física, Facultad de Ciencias, Las Palmeras 3425, Ñuñoa, Santiago (Chile); Arellano, H. F. [Universidad de Chile, DFI, Facultad de Ciencias Físicas Y Matemáticas, Avenida Blanco Encalada 2008, Santiago (Chile)

    2016-07-07

    The neutron self–shielding factor G as a function of the neutron energy was obtained for 14 pure metallic samples in 1000 isolethargic energy bins from 1·10{sup −5}eV to 2·10{sup 7}eV using Monte Carlo simulations in GEANT4 and MCNP6. The comparison of these two Monte Carlo codes shows small differences in the final self–shielding factor mostly due to the different cross section databases that each program uses.

  5. Physical Processes and Applications of the Monte Carlo Radiative Energy Deposition (MRED) Code

    Science.gov (United States)

    Reed, Robert A.; Weller, Robert A.; Mendenhall, Marcus H.; Fleetwood, Daniel M.; Warren, Kevin M.; Sierawski, Brian D.; King, Michael P.; Schrimpf, Ronald D.; Auden, Elizabeth C.

    2015-08-01

    MRED is a Python-language scriptable computer application that simulates radiation transport. It is the computational engine for the on-line tool CRÈME-MC. MRED is based on c++ code from Geant4 with additional Fortran components to simulate electron transport and nuclear reactions with high precision. We provide a detailed description of the structure of MRED and the implementation of the simulation of physical processes used to simulate radiation effects in electronic devices and circuits. Extensive discussion and references are provided that illustrate the validation of models used to implement specific simulations of relevant physical processes. Several applications of MRED are summarized that demonstrate its ability to predict and describe basic physical phenomena associated with irradiation of electronic circuits and devices. These include effects from single particle radiation (including both direct ionization and indirect ionization effects), dose enhancement effects, and displacement damage effects. MRED simulations have also helped to identify new single event upset mechanisms not previously observed by experiment, but since confirmed, including upsets due to muons and energetic electrons.

  6. Validation of nuclear models in Geant4 using the dose distribution of a 177 MeV proton pencil beam

    International Nuclear Information System (INIS)

    Hall, David C; Paganetti, Harald; Makarova, Anastasia; Gottschalk, Bernard

    2016-01-01

    A proton pencil beam is associated with a surrounding low-dose envelope, originating from nuclear interactions. It is important for treatment planning systems to accurately model this envelope when performing dose calculations for pencil beam scanning treatments, and Monte Carlo (MC) codes are commonly used for this purpose. This work aims to validate the nuclear models employed by the Geant4 MC code, by comparing the simulated absolute dose distribution to a recent experiment of a 177 MeV proton pencil beam stopping in water. Striking agreement is observed over five orders of magnitude, with both the shape and normalisation well modelled. The normalisations of two depth dose curves are lower than experiment, though this could be explained by an experimental positioning error. The Geant4 neutron production model is also verified in the distal region. The entrance dose is poorly modelled, suggesting an unaccounted upstream source of low-energy protons. Recommendations are given for a follow-up experiment which could resolve these issues. (note)

  7. Modeling Monte Carlo of multileaf collimators using the code GEANT4

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Alex C.H.; Lima, Fernando R.A., E-mail: oliveira.ach@yahoo.com, E-mail: falima@cnen.gov.br [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Lima, Luciano S.; Vieira, Jose W., E-mail: lusoulima@yahoo.com.br [Instituto Federal de Educacao, Ciencia e Tecnologia de Pernambuco (IFPE), Recife, PE (Brazil)

    2014-07-01

    Radiotherapy uses various techniques and equipment for local treatment of cancer. The equipment most often used in radiotherapy to the patient irradiation is linear accelerator (Linac). Among the many algorithms developed for evaluation of dose distributions in radiotherapy planning, the algorithms based on Monte Carlo (MC) methods have proven to be very promising in terms of accuracy by providing more realistic results. The MC simulations for applications in radiotherapy are divided into two parts. In the first, the simulation of the production of the radiation beam by the Linac is performed and then the phase space is generated. The phase space contains information such as energy, position, direction, etc. of millions of particles (photons, electrons, positrons). In the second part the simulation of the transport of particles (sampled phase space) in certain configurations of irradiation field is performed to assess the dose distribution in the patient (or phantom). Accurate modeling of the Linac head is of particular interest in the calculation of dose distributions for intensity modulated radiation therapy (IMRT), where complex intensity distributions are delivered using a multileaf collimator (MLC). The objective of this work is to describe a methodology for modeling MC of MLCs using code Geant4. To exemplify this methodology, the Varian Millennium 120-leaf MLC was modeled, whose physical description is available in BEAMnrc Users Manual (20 11). The dosimetric characteristics (i.e., penumbra, leakage, and tongue-and-groove effect) of this MLC were evaluated. The results agreed with data published in the literature concerning the same MLC. (author)

  8. GeantV: from CPU to accelerators

    Science.gov (United States)

    Amadio, G.; Ananya, A.; Apostolakis, J.; Arora, A.; Bandieramonte, M.; Bhattacharyya, A.; Bianchini, C.; Brun, R.; Canal, P.; Carminati, F.; Duhem, L.; Elvira, D.; Gheata, A.; Gheata, M.; Goulas, I.; Iope, R.; Jun, S.; Lima, G.; Mohanty, A.; Nikitina, T.; Novak, M.; Pokorski, W.; Ribon, A.; Sehgal, R.; Shadura, O.; Vallecorsa, S.; Wenzel, S.; Zhang, Y.

    2016-10-01

    The GeantV project aims to research and develop the next-generation simulation software describing the passage of particles through matter. While the modern CPU architectures are being targeted first, resources such as GPGPU, Intel© Xeon Phi, Atom or ARM cannot be ignored anymore by HEP CPU-bound applications. The proof of concept GeantV prototype has been mainly engineered for CPU's having vector units but we have foreseen from early stages a bridge to arbitrary accelerators. A software layer consisting of architecture/technology specific backends supports currently this concept. This approach allows to abstract out the basic types such as scalar/vector but also to formalize generic computation kernels using transparently library or device specific constructs based on Vc, CUDA, Cilk+ or Intel intrinsics. While the main goal of this approach is portable performance, as a bonus, it comes with the insulation of the core application and algorithms from the technology layer. This allows our application to be long term maintainable and versatile to changes at the backend side. The paper presents the first results of basket-based GeantV geometry navigation on the Intel© Xeon Phi KNC architecture. We present the scalability and vectorization study, conducted using Intel performance tools, as well as our preliminary conclusions on the use of accelerators for GeantV transport. We also describe the current work and preliminary results for using the GeantV transport kernel on GPUs.

  9. GeantV: from CPU to accelerators

    International Nuclear Information System (INIS)

    Amadio, G; Bianchini, C; Iope, R; Ananya, A; Arora, A; Apostolakis, J; Bandieramonte, M; Brun, R; Carminati, F; Gheata, A; Gheata, M; Goulas, I; Nikitina, T; Bhattacharyya, A; Mohanty, A; Canal, P; Elvira, D; Jun, S; Lima, G; Duhem, L

    2016-01-01

    The GeantV project aims to research and develop the next-generation simulation software describing the passage of particles through matter. While the modern CPU architectures are being targeted first, resources such as GPGPU, Intel© Xeon Phi, Atom or ARM cannot be ignored anymore by HEP CPU-bound applications. The proof of concept GeantV prototype has been mainly engineered for CPU's having vector units but we have foreseen from early stages a bridge to arbitrary accelerators. A software layer consisting of architecture/technology specific backends supports currently this concept. This approach allows to abstract out the basic types such as scalar/vector but also to formalize generic computation kernels using transparently library or device specific constructs based on Vc, CUDA, Cilk+ or Intel intrinsics. While the main goal of this approach is portable performance, as a bonus, it comes with the insulation of the core application and algorithms from the technology layer. This allows our application to be long term maintainable and versatile to changes at the backend side. The paper presents the first results of basket-based GeantV geometry navigation on the Intel© Xeon Phi KNC architecture. We present the scalability and vectorization study, conducted using Intel performance tools, as well as our preliminary conclusions on the use of accelerators for GeantV transport. We also describe the current work and preliminary results for using the GeantV transport kernel on GPUs. (paper)

  10. Monte Carlo simulation in nuclear medicine, radiotherapy-brachytherapy with a simulation platform GATE based on Geant4

    International Nuclear Information System (INIS)

    Berger, L.; Breton, V.; Donnarieix, D.; Elbitar, Z.; Gisclon, D.; Lazaro, D.; Maigne, L.; Reuillon, R.; Thiam, C.O.; Donnarieix, D.

    2003-01-01

    The totality of simulations made with the G.A.T.E. software gives extremely conclusive results. Its easiness to use and the power of the G.E.A.N.T.4. simulation code make of it a performing tool. The works made to parallel the simulation code reduce considerably the calculation time for a given simulation. A public version is planned for may 2004. (N.C.)

  11. A Geant4 simulation package for the TASISpec experimental detector setup

    Energy Technology Data Exchange (ETDEWEB)

    Sarmiento, L.G., E-mail: lgsarmientop@unal.edu.co [Universidad Nacional de Colombia, Bogota D.C. 111321 (Colombia); Lund University, S-22100 Lund (Sweden); Andersson, L.-L. [University of Liverpool, Oliver Lodge Laboratory, Liverpool L69 7ZE (United Kingdom); Rudolph, D. [Lund University, S-22100 Lund (Sweden)

    2012-03-01

    The experimental detector setup TASISpec (TA SCA in Small Image mode Spectroscopy) comprises composite Ge- and highly segmented Si-detectors. The setup is constructed to provide multi-coincidence spectroscopic data between {gamma}-rays, X-rays, conversion electrons, fission fragments, and {alpha}-particles for heavy and superheavy elements (Z{>=}100). The full array has been virtually constructed using the Geant4 simulation toolkit. The simulations will not only be used to explore the possibilities of the detector setup itself. More important, however, they will also shed light on the nuclear structure of the heaviest elements. This can be done by comparing the simulated detector response of complex decay modes with the experimental data. Such an iterative or 'self-consistent' way to understand experimental observables will provide more reliability when disentangling the data and deducing experimental decay schemes.

  12. Geant4 calculations for space radiation shielding material Al2O3

    Science.gov (United States)

    Capali, Veli; Acar Yesil, Tolga; Kaya, Gokhan; Kaplan, Abdullah; Yavuz, Mustafa; Tilki, Tahir

    2015-07-01

    Aluminium Oxide, Al2O3 is the most widely used material in the engineering applications. It is significant aluminium metal, because of its hardness and as a refractory material owing to its high melting point. This material has several engineering applications in diverse fields such as, ballistic armour systems, wear components, electrical and electronic substrates, automotive parts, components for electric industry and aero-engine. As well, it is used as a dosimeter for radiation protection and therapy applications for its optically stimulated luminescence properties. In this study, stopping powers and penetrating distances have been calculated for the alpha, proton, electron and gamma particles in space radiation shielding material Al2O3 for incident energies 1 keV - 1 GeV using GEANT4 calculation code.

  13. The performance of a new Geant4 Bertini intra-nuclear cascade model in high throughput computing (HTC) cluster architecture

    Energy Technology Data Exchange (ETDEWEB)

    Aatos, Heikkinen; Andi, Hektor; Veikko, Karimaki; Tomas, Linden [Helsinki Univ., Institute of Physics (Finland)

    2003-07-01

    We study the performance of a new Bertini intra-nuclear cascade model implemented in the general detector simulation tool-kit Geant4 with a High Throughput Computing (HTC) cluster architecture. A 60 node Pentium III open-Mosix cluster is used with the Mosix kernel performing automatic process load-balancing across several CPUs. The Mosix cluster consists of several computer classes equipped with Windows NT workstations that automatically boot, daily and become nodes of the Mosix cluster. The models included in our study are a Bertini intra-nuclear cascade model with excitons, consisting of a pre-equilibrium model, a nucleus explosion model, a fission model and an evaporation model. The speed and accuracy obtained for these models is presented. (authors)

  14. Simulation and modeling for the stand-off radiation detection system (SORDS) using GEANT4

    Energy Technology Data Exchange (ETDEWEB)

    Hoover, Andrew S [Los Alamos National Laboratory; Wallace, Mark [Los Alamos National Laboratory; Galassi, Mark [Los Alamos National Laboratory; Mocko, Michal [Los Alamos National Laboratory; Palmer, David [Los Alamos National Laboratory; Schultz, Larry [Los Alamos National Laboratory; Tornga, Shawn [Los Alamos National Laboratory

    2009-01-01

    A Stand-Off Radiation Detection System (SORDS) is being developed through a joint effort by Raytheon, Los Alamos National Laboratory, Bubble Technology Industries, Radiation Monitoring Devices, and the Massachusetts Institute of Technology, for the Domestic Nuclear Detection Office (DNDO). The system is a mobile truck-based platform performing detection, imaging, and spectroscopic identification of gamma-ray sources. A Tri-Modal Imaging (TMI) approach combines active-mask coded aperture imaging, Compton imaging, and shadow imaging techniques. Monte Carlo simulation and modeling using the GEANT4 toolkit was used to generate realistic data for the development of imaging algorithms and associated software code.

  15. Efficiency transfer using the GEANT4 code of CERN for HPGe gamma spectrometry.

    Science.gov (United States)

    Chagren, S; Tekaya, M Ben; Reguigui, N; Gharbi, F

    2016-01-01

    In this work we apply the GEANT4 code of CERN to calculate the peak efficiency in High Pure Germanium (HPGe) gamma spectrometry using three different procedures. The first is a direct calculation. The second corresponds to the usual case of efficiency transfer between two different configurations at constant emission energy assuming a reference point detection configuration and the third, a new procedure, consists on the transfer of the peak efficiency between two detection configurations emitting the gamma ray in different energies assuming a "virtual" reference point detection configuration. No pre-optimization of the detector geometrical characteristics was performed before the transfer to test the ability of the efficiency transfer to reduce the effect of the ignorance on their real magnitude on the quality of the transferred efficiency. The obtained and measured efficiencies were found in good agreement for the two investigated methods of efficiency transfer. The obtained agreement proves that Monte Carlo method and especially the GEANT4 code constitute an efficient tool to obtain accurate detection efficiency values. The second investigated efficiency transfer procedure is useful to calibrate the HPGe gamma detector for any emission energy value for a voluminous source using one point source detection efficiency emitting in a different energy as a reference efficiency. The calculations preformed in this work were applied to the measurement exercise of the EUROMET428 project. A measurement exercise where an evaluation of the full energy peak efficiencies in the energy range 60-2000 keV for a typical coaxial p-type HpGe detector and several types of source configuration: point sources located at various distances from the detector and a cylindrical box containing three matrices was performed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Geant4 calculations for space radiation shielding material Al2O3

    Directory of Open Access Journals (Sweden)

    Capali Veli

    2015-01-01

    Full Text Available Aluminium Oxide, Al2O3 is the most widely used material in the engineering applications. It is significant aluminium metal, because of its hardness and as a refractory material owing to its high melting point. This material has several engineering applications in diverse fields such as, ballistic armour systems, wear components, electrical and electronic substrates, automotive parts, components for electric industry and aero-engine. As well, it is used as a dosimeter for radiation protection and therapy applications for its optically stimulated luminescence properties. In this study, stopping powers and penetrating distances have been calculated for the alpha, proton, electron and gamma particles in space radiation shielding material Al2O3 for incident energies 1 keV – 1 GeV using GEANT4 calculation code.

  17. Muon Telescope (MuTe): A first study using Geant4

    Science.gov (United States)

    Asorey, H.; Balaguera-Rojas, A.; Calderon-Ardila, R.; Núñez, L. A.; Sanabria-Gómez, J. D.; Súarez-Durán, M.; Tapia, A.

    2017-07-01

    Muon tomography is based on recording the difference of absorption of muons by matter, as ordinary radiography does for using X-rays. The interaction of cosmic rays with the atmosphere produces extensive air showers which provides an abundant source for atmospheric muons, benefiting various applications of muon tomography, particularly the study of the inner structure of volcanoes. The MuTe (for Muon Telescope) is a hybrid detector composed of scintillation bars and a water Cherenkov detector designed to measure cosmic muon flux crossing volcanic edifices. This detector consists of two scintillator plates (1.44 m2 with 30 x 30 pixels), with a maximum distance of 2.0m of separation. In this work we report the first simulation of the MuTe using GEANT4 -set of simulation tools, based in C++ - that provides information about the interaction between radiation and matter. This computational tool allows us to know the energy deposited by the muons and modeling the response of the scintillators and the water cherenkov detector to the passage of radiation which is crucial to compare to our data analysis.

  18. Design and optimization of an energy degrader with a multi-wedge scheme based on Geant4

    Science.gov (United States)

    Liang, Zhikai; Liu, Kaifeng; Qin, Bin; Chen, Wei; Liu, Xu; Li, Dong; Xiong, Yongqian

    2018-05-01

    A proton therapy facility based on an isochronous superconducting cyclotron is under construction in Huazhong University of Science and Technology (HUST). To meet the clinical requirements, an energy degrader is essential in the beamline to modulate the fixed beam energy extracted from the cyclotron. Because of the multiple Coulomb scattering in the degrader, the beam emittance and the energy spread will be considerably increased during the energy degradation process. Therefore, a set of collimators is designed to restrict the increase in beam emittance after the energy degradation. The energy spread will be reduced in the following beam line which is not discussed in this paper. In this paper, the design considerations of an energy degrader and collimators are introduced, and the properties of the degrader material, degrader structure and the initial beam parameters are discussed using the Geant4 Monte-Carlo toolkit, with the main purpose of improving the overall performance of the degrader by multiple parameter optimization.

  19. The implementation of quality controls of gamma camera functioning and simulation of tomography techniques by Gate and GEANT4

    International Nuclear Information System (INIS)

    Ben Ameur, Narjes

    2011-01-01

    The reliability of medical devices is directly linked to the services quality offered to the patient. For this reason, quality control tests should be regularly conducted in every nuclear medicine service according to international norms. Our approach consists on realizing different quality control tests recommended by the Nema norm on a gamma-camera in order to evaluate its performance. The obtained data allowed us to study the different physical phenomena happening during a SPECT exam. It also allowed us to identify those affecting the image quality based on the simulation programmes: GEANT 4 and Gate. The obtained results of the quality control showed that the Gamma-camera has a high performance in terms of spatial resolution, linearity, uniformity and rotational center. The establishment of a model for a gamma-camera Symbia E (Siemens) using a Gate platform confirms the reliability of this platform in the conception and the optimization of the detectors.

  20. Consistency evaluation between EGSnrc and Geant4 charged particle transport in an equilibrium magnetic field.

    Science.gov (United States)

    Yang, Y M; Bednarz, B

    2013-02-21

    Following the proposal by several groups to integrate magnetic resonance imaging (MRI) with radiation therapy, much attention has been afforded to examining the impact of strong (on the order of a Tesla) transverse magnetic fields on photon dose distributions. The effect of the magnetic field on dose distributions must be considered in order to take full advantage of the benefits of real-time intra-fraction imaging. In this investigation, we compared the handling of particle transport in magnetic fields between two Monte Carlo codes, EGSnrc and Geant4, to analyze various aspects of their electromagnetic transport algorithms; both codes are well-benchmarked for medical physics applications in the absence of magnetic fields. A water-air-water slab phantom and a water-lung-water slab phantom were used to highlight dose perturbations near high- and low-density interfaces. We have implemented a method of calculating the Lorentz force in EGSnrc based on theoretical models in literature, and show very good consistency between the two Monte Carlo codes. This investigation further demonstrates the importance of accurate dosimetry for MRI-guided radiation therapy (MRIgRT), and facilitates the integration of a ViewRay MRIgRT system in the University of Wisconsin-Madison's Radiation Oncology Department.

  1. Consistency evaluation between EGSnrc and Geant4 charged particle transport in an equilibrium magnetic field

    International Nuclear Information System (INIS)

    Yang, Y M; Bednarz, B

    2013-01-01

    Following the proposal by several groups to integrate magnetic resonance imaging (MRI) with radiation therapy, much attention has been afforded to examining the impact of strong (on the order of a Tesla) transverse magnetic fields on photon dose distributions. The effect of the magnetic field on dose distributions must be considered in order to take full advantage of the benefits of real-time intra-fraction imaging. In this investigation, we compared the handling of particle transport in magnetic fields between two Monte Carlo codes, EGSnrc and Geant4, to analyze various aspects of their electromagnetic transport algorithms; both codes are well-benchmarked for medical physics applications in the absence of magnetic fields. A water–air–water slab phantom and a water–lung–water slab phantom were used to highlight dose perturbations near high- and low-density interfaces. We have implemented a method of calculating the Lorentz force in EGSnrc based on theoretical models in literature, and show very good consistency between the two Monte Carlo codes. This investigation further demonstrates the importance of accurate dosimetry for MRI-guided radiation therapy (MRIgRT), and facilitates the integration of a ViewRay MRIgRT system in the University of Wisconsin-Madison's Radiation Oncology Department. (note)

  2. Dose calculations at high altitudes and in deep space with GEANT4 using BIC and JQMD models for nucleus-nucleus reactions

    International Nuclear Information System (INIS)

    Sihver, L; Mancusi, D; Matthiae, D; Koi, T

    2008-01-01

    Radiation exposure of aircrew is more and more recognized as an occupational hazard. The ionizing environment at standard commercial aircraft flight altitudes consists mainly of secondary particles, of which the neutrons give a major contribution to the dose equivalent. Accurate estimations of neutron spectra in the atmosphere are therefore essential for correct calculations of aircrew doses. Energetic solar particle events (SPE) could also lead to significantly increased dose rates, especially at routes close to the North Pole, e.g. for flights between Europe and USA. It is also well known that the radiation environment encountered by personnel aboard low Earth orbit (LEO) spacecraft or aboard a spacecraft traveling outside the Earth's protective magnetosphere is much harsher compared with that within the atmosphere since the personnel are exposed to radiation from both galactic cosmic rays (GCR) and SPE. The relative contribution to the dose from GCR when traveling outside the Earth's magnetosphere, e.g. to the Moon or Mars, is even greater, and reliable and accurate particle and heavy ion transport codes are essential to calculate the radiation risks for both aircrew and personnel on spacecraft. We have therefore performed calculations of neutron distributions in the atmosphere, total dose equivalents, and quality factors at different depths in a water sphere in an imaginary spacecraft during solar minimum in a geosynchronous orbit. The calculations were performed with the GEANT4 Monte Carlo (MC) code using both the binary cascade (BIC) model, which is part of the standard GEANT4 package, and the JQMD model, which is used in the particle and heavy ion transport code PHITS GEANT4.

  3. Dose calculations at high altitudes and in deep space with GEANT4 using BIC and JQMD models for nucleus nucleus reactions

    Science.gov (United States)

    Sihver, L.; Matthiä, D.; Koi, T.; Mancusi, D.

    2008-10-01

    Radiation exposure of aircrew is more and more recognized as an occupational hazard. The ionizing environment at standard commercial aircraft flight altitudes consists mainly of secondary particles, of which the neutrons give a major contribution to the dose equivalent. Accurate estimations of neutron spectra in the atmosphere are therefore essential for correct calculations of aircrew doses. Energetic solar particle events (SPE) could also lead to significantly increased dose rates, especially at routes close to the North Pole, e.g. for flights between Europe and USA. It is also well known that the radiation environment encountered by personnel aboard low Earth orbit (LEO) spacecraft or aboard a spacecraft traveling outside the Earth's protective magnetosphere is much harsher compared with that within the atmosphere since the personnel are exposed to radiation from both galactic cosmic rays (GCR) and SPE. The relative contribution to the dose from GCR when traveling outside the Earth's magnetosphere, e.g. to the Moon or Mars, is even greater, and reliable and accurate particle and heavy ion transport codes are essential to calculate the radiation risks for both aircrew and personnel on spacecraft. We have therefore performed calculations of neutron distributions in the atmosphere, total dose equivalents, and quality factors at different depths in a water sphere in an imaginary spacecraft during solar minimum in a geosynchronous orbit. The calculations were performed with the GEANT4 Monte Carlo (MC) code using both the binary cascade (BIC) model, which is part of the standard GEANT4 package, and the JQMD model, which is used in the particle and heavy ion transport code PHITS GEANT4.

  4. Monte Carlo simulation of fission yields, kinetic energy, fission neutron spectrum and decay γ-ray spectrum for 232Th(n,f) reaction induced by 3H(d,n) 4He neutron source

    International Nuclear Information System (INIS)

    Zheng Wei; Zeen Yao; Changlin Lan; Yan Yan; Yunjian Shi; Siqi Yan; Jie Wang; Junrun Wang; Jingen Chen; Chinese Academy of Sciences, Shanghai

    2015-01-01

    Monte Carlo transport code Geant4 has been successfully utilised to study of neutron-induced fission reaction for 232 Th in the transport neutrons generated from 3 H(d,n) 4 He neutron source. The purpose of this work is to examine the applicability of Monte Carlo simulations for the computation of fission reaction process. For this, Monte Carlo simulates and calculates the characteristics of fission reaction process of 232 Th(n,f), such as the fission yields distribution, kinetic energy distribution, fission neutron spectrum and decay γ-ray spectrum. This is the first time to simulate the process of neutron-induced fission reaction using Geant4 code. Typical computational results of neutron-induced fission reaction of 232 Th(n,f) reaction are presented. The computational results are compared with the previous experimental data and evaluated nuclear data to confirm the certain physical process model in Geant4 of scientific rationality. (author)

  5. Opticks : GPU Optical Photon Simulation for Particle Physics using NVIDIA® OptiX™

    Science.gov (United States)

    C, Blyth Simon

    2017-10-01

    Opticks is an open source project that integrates the NVIDIA OptiX GPU ray tracing engine with Geant4 toolkit based simulations. Massive parallelism brings drastic performance improvements with optical photon simulation speedup expected to exceed 1000 times Geant4 when using workstation GPUs. Optical photon simulation time becomes effectively zero compared to the rest of the simulation. Optical photons from scintillation and Cherenkov processes are allocated, generated and propagated entirely on the GPU, minimizing transfer overheads and allowing CPU memory usage to be restricted to optical photons that hit photomultiplier tubes or other photon detectors. Collecting hits into standard Geant4 hit collections then allows the rest of the simulation chain to proceed unmodified. Optical physics processes of scattering, absorption, scintillator reemission and boundary processes are implemented in CUDA OptiX programs based on the Geant4 implementations. Wavelength dependent material and surface properties as well as inverse cumulative distribution functions for reemission are interleaved into GPU textures providing fast interpolated property lookup or wavelength generation. Geometry is provided to OptiX in the form of CUDA programs that return bounding boxes for each primitive and ray geometry intersection positions. Some critical parts of the geometry such as photomultiplier tubes have been implemented analytically with the remainder being tessellated. OptiX handles the creation and application of a choice of acceleration structures such as boundary volume hierarchies and the transparent use of multiple GPUs. OptiX supports interoperation with OpenGL and CUDA Thrust that has enabled unprecedented visualisations of photon propagations to be developed using OpenGL geometry shaders to provide interactive time scrubbing and CUDA Thrust photon indexing to enable interactive history selection.

  6. GEANT4 simulation study of a gamma-ray detector for neutron resonance densitometry

    International Nuclear Information System (INIS)

    Tsuchiya, Harufumi; Harada, Hideo; Koizumi, Mitsuo; Kitatani, Fumito; Takamine, Jun; Kureta, Masatoshi; Iimura, Hideki

    2013-01-01

    A design study of a gamma-ray detector for neutron resonance densitometry was made with GEANT4. The neutron resonance densitometry, combining neutron resonance transmission analysis and neutron resonance capture analysis, is a non-destructive technique to measure amounts of nuclear materials in melted fuels of the Fukushima Daiichi nuclear power plants. In order to effectively quantify impurities in the melted fuels via prompt gamma-ray measurements, a gamma-ray detector for the neutron resonance densitometry consists of cylindrical and well type LaBr 3 scintillators. The present simulation showed that the proposed gamma-ray detector suffices to clearly detect the gamma rays emitted by 10 B(n, αγ) reaction in a high environmental background due to 137 Cs radioactivity with its Compton edge suppressed at a considerably small level. (author)

  7. The simulation of the LANFOS-H food radiation contamination detector using Geant4 package

    Science.gov (United States)

    Piotrowski, Lech Wiktor; Casolino, Marco; Ebisuzaki, Toshikazu; Higashide, Kazuhiro

    2015-02-01

    Recent incident in the Fukushima power plant caused a growing concern about the radiation contamination and resulted in lowering the Japanese limits for the permitted amount of 137Cs in food to 100 Bq/kg. To increase safety and ease the concern we are developing LANFOS (Large Food Non-destructive Area Sampler)-a compact, easy to use detector for assessment of radiation in food. Described in this paper LANFOS-H has a 4 π coverage to assess the amount of 137Cs present, separating it from the possible 40K food contamination. Therefore, food samples do not have to be pre-processed prior to a test and can be consumed after measurements. It is designed for use by non-professionals in homes and small institutions such as schools, showing safety of the samples, but can be also utilized by specialists providing radiation spectrum. Proper assessment of radiation in food in the apparatus requires estimation of the γ conversion factor of the detectors-how many γ photons will produce a signal. In this paper we show results of the Monte Carlo estimation of this factor for various approximated shapes of fish, vegetables and amounts of rice, performed with Geant4 package. We find that the conversion factor combined from all the detectors is similar for all food types and is around 37%, varying maximally by 5% with sample length, much less than for individual detectors. The different inclinations and positions of samples in the detector introduce uncertainty of 1.4%. This small uncertainty validates the concept of a 4 π non-destructive apparatus.

  8. Implementation of a model in Geant4 of an accelerator on Cloudmc, a Web application for the parallelization of Monte Carlo simulations in the Cloud; Implementacion de un modelo en Geant4 de un acelerador en Cloudmc, una aplicacion Web para la paralelizacion de simulaciones Monte Carlo en la nube

    Energy Technology Data Exchange (ETDEWEB)

    Miras del Rio, H.; Jimenez Marrufo, R.; Cortes Giraldo, M. A.; Miras del Rio, C.

    2013-07-01

    This paper describes the implementation in CloudMC of a simulation program MC, based on the code of Geant4, a Siemens Accelerator model Oncor with the intention that in future can be used for calculation of radiation treatments with MC in short periods of time. (Author)

  9. ALGEBRA: ALgorithm for the heterogeneous dosimetry based on GEANT4 for BRAchytherapy.

    Science.gov (United States)

    Afsharpour, H; Landry, G; D'Amours, M; Enger, S; Reniers, B; Poon, E; Carrier, J-F; Verhaegen, F; Beaulieu, L

    2012-06-07

    Task group 43 (TG43)-based dosimetry algorithms are efficient for brachytherapy dose calculation in water. However, human tissues have chemical compositions and densities different than water. Moreover, the mutual shielding effect of seeds on each other (interseed attenuation) is neglected in the TG43-based dosimetry platforms. The scientific community has expressed the need for an accurate dosimetry platform in brachytherapy. The purpose of this paper is to present ALGEBRA, a Monte Carlo platform for dosimetry in brachytherapy which is sufficiently fast and accurate for clinical and research purposes. ALGEBRA is based on the GEANT4 Monte Carlo code and is capable of handling the DICOM RT standard to recreate a virtual model of the treated site. Here, the performance of ALGEBRA is presented for the special case of LDR brachytherapy in permanent prostate and breast seed implants. However, the algorithm is also capable of handling other treatments such as HDR brachytherapy.

  10. Physics validation studies for muon collider detector background simulations

    International Nuclear Information System (INIS)

    Morris, Aaron Owen

    2011-01-01

    Within the broad discipline of physics, the study of the fundamental forces of nature and the most basic constituents of the universe belongs to the field of particle physics. While frequently referred to as 'high-energy physics,' or by the acronym 'HEP,' particle physics is not driven just by the quest for ever-greater energies in particle accelerators. Rather, particle physics is seen as having three distinct areas of focus: the cosmic, intensity, and energy frontiers. These three frontiers all provide different, but complementary, views of the basic building blocks of the universe. Currently, the energy frontier is the realm of hadron colliders like the Tevatron at Fermi National Accelerator Laboratory (Fermilab) or the Large Hadron Collider (LHC) at CERN. While the LHC is expected to be adequate for explorations up to 14 TeV for the next decade, the long development lead time for modern colliders necessitates research and development efforts in the present for the next generation of colliders. This paper focuses on one such next-generation machine: a muon collider. Specifically, this paper focuses on Monte Carlo simulations of beam-induced backgrounds vis-a-vis detector region contamination. Initial validation studies of a few muon collider physics background processes using G4beamline have been undertaken and results presented. While these investigations have revealed a number of hurdles to getting G4beamline up to the level of more established simulation suites, such as MARS, the close communication between us, as users, and the G4beamline developer, Tom Roberts, has allowed for rapid implementation of user-desired features. The main example of user-desired feature implementation, as it applies to this project, is Bethe-Heitler muon production. Regarding the neutron interaction issues, we continue to study the specifics of how GEANT4 implements nuclear interactions. The GEANT4 collaboration has been contacted regarding the minor discrepancies in the neutron

  11. Development of a Geant4 application to characterise a prototype neutron detector based on three orthogonal 3He tubes inside an HDPE sphere.

    Science.gov (United States)

    Gracanin, V; Guatelli, S; Prokopovich, D; Rosenfeld, A B; Berry, A

    2017-01-01

    The Bonner Sphere Spectrometer (BSS) system is a well-established technique for neutron dosimetry that involves detection of thermal neutrons within a range of hydrogenous moderators. BSS detectors are often used to perform neutron field surveys in order to determine the ambient dose equivalent H*(10) and estimate health risk to personnel. There is a potential limitation of existing neutron survey techniques, since some detectors do not consider the direction of the neutron field, which can result in overly conservative estimates of dose in neutron fields. This paper shows the development of a Geant4 simulation application to characterise a prototype neutron detector based on three orthogonal 3 He tubes inside a single HDPE sphere built at the Australian Nuclear Science and Technology Organisation (ANSTO). The Geant4 simulation has been validated with respect to experimental measurements performed with an Am-Be source. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  12. Monte Carlo simulation of dose calculation in voxel and geometric phantoms using GEANT4 code

    International Nuclear Information System (INIS)

    Martins, Maximiano C.; Santos, Denison de S.; Queiroz Filho, Pedro P. de; Silva, Rosana de S. e; Begalli, Marcia

    2009-01-01

    Monte Carlo simulation techniques have become a valuable tool for scientific purposes. In radiation protection many quantities are obtained by means of the simulation of particles passing through human body models, also known as phantoms, allowing the calculation of doses deposited in an individual's organs exposed to ionizing radiation. These information are very useful from the medical viewpoint, as they are used in the planning of external beam radiotherapy and brachytherapy treatments. The goal of this work is the implementation of a voxel phantom and a geometrical phantom in the framework of the Geant4 tool kit, aiming at a future use of this code by professionals in the medical area. (author)

  13. Optimization of {sup 6}LiF:ZnS(Ag) Scintillator Light Yield Using Geant4

    Energy Technology Data Exchange (ETDEWEB)

    Yehuda-Zada, Y. [Nuclear Research Center Negev, Beer-Sheva (Israel); Ben-Gurion University (Israel); Pritchard, K.; Ziegler, J.B.; Cooksey, C.; Siebein, K. [National Institute of Standards and Technology, Gaithersburg, Maryland (United States); Jackson, M.; Hurlbut, C. [Eljen Technology, Sweetwater Texas (United States); Kadmon, Y.; Cohen, Y.; Maliszewskyj, N.C. [Nuclear Research Center Negev, Beer-Sheva (Israel); Ibberson, R.M.; Majkrzak, C.F. [National Institute of Standards and Technology, Gaithersburg, Maryland (United States); Orion, Y. [Ben-Gurion University (Israel); Osovizky, A. [National Institute of Standards and Technology, Gaithersburg, Maryland (United States); Rotem Industries Ltd, Rotem Industrial Park (Israel); University of Maryland (United States)

    2015-07-01

    Neutrons provide an effective tool to probe materials structure. Neutron diffraction is a method to determine the atomic and magnetic structure of a material based on neutron scattering. By this method a collimated incident beam of thermal neutrons heat the examined sample and based on the obtained diffraction pattern information on the structure of the material is provided. Research for developing a novel cold neutron detector for Chromatic Analysis Neutron Diffractometer Or Reflectometer (CANDOR) is underway at the NIST center for neutron research. The system unique design is aimed to provide over ten times fold faster analysis of materials than conventional system. In order to achieve the fast analysis a large number of neutron detectors is required. A key design constraint for this detector is the thickness of the neutron sensitive element. This is met using {sup 6}LiF:ZnS(Ag) scintillation material with embedded wavelength shifting (WLS) fibers conducting scintillation light to silicon photomultiplier photo-sensors. The detector sensitivity is determined by both the neutron capture probability ({sup 6}Li density) and the detectable light output produced by the ZnS(Ag) ionization, the latter of which is hindered by the fluorescence absorption of the scintillation light by the ZnS. Tradeoffs between the neutron capture probability, stimulated light production and light attenuation for determining the optimal stoichiometry of the {sup 6}LiF and ZnS(Ag) as well as the volume ratio of scintillator and fiber. Simulations performed using the GEANT4 Monte Carlo package were made in order to optimize the detector design. GEANT4 enables the investigation of the neutron interaction with the detector, the ionization process and the light transfer process following the nuclear process. The series of conversions required for this detector were modelled: - A cold neutron enters the sensor and is captured by {sup 6}Li in the scintillator mixture ({sup 6}Li (n,α) {sup 3}H

  14. Geant4 simulation for a study of a possible use of carbon ions pencil beam for the treatment of ocular melanomas with the active scanning system at CNAO Centre

    International Nuclear Information System (INIS)

    Farina, E.; Piersimoni, P.; Riccardi, C.; Rimoldi, A.; Tamborini, A.; Ciocca, M.

    2015-01-01

    The aim of this work is to validate the Geant4 application reproducing the CNAO (National Centre for Oncological Hadrontherapy) beamline and to study of a possible use of carbon ion pencil beams for the treatment of ocular melanomas at the CNAO Centre. The promising aspect of carbon ions radiotherapy for the treatment of this disease lies in its superior relative radiobiological effectiveness (RBE). The Monte Carlo Geant4 toolkit is used to simulate the complete CNAO extraction beamline, with the active and passive components along it. A human eye modeled detector, including a realistic target tumor volume, is used as target. Cross check with previous studies at CNAO using protons allows comparisons on possible benefits on using such a technique with respect to proton beams. Before the eye-detector irradiation a validation of the Geant4 simulation with CNAO experimental data is carried out with both carbon ions and protons. Important beam parameters such as the transverse FWHM and scanned radiation field 's uniformity are tested within the simulation and compared with experimental measurements at CNAO Centre. The physical processes involved in secondary particles generation by carbon ions and protons in the eye-detector are reproduced to take into account the additional dose to the primary beam given to irradiated eye's tissues. A study of beam shaping is carried out to produce a uniform 3D dose distribution (shaped on the tumor) by the use of a spread out Bragg peak. The eye-detector is then irradiated through a two dimensional transverse beam scan at different depths. In the use case the eye-detector is rotated of an angle of 40 deg. in the vertical direction, in order to mis-align the tumor from healthy tissues in front of it. The treatment uniformity on the tumor in the eye-detector is tested. For a more quantitative description of the deposited dose in the eye-detector and for the evaluation of the ratio between the dose deposited in the tumor and

  15. Geant4 simulation for a study of a possible use of carbon ions pencil beam for the treatment of ocular melanomas with the active scanning system at CNAO Centre

    Energy Technology Data Exchange (ETDEWEB)

    Farina, E. [University of Pavia-Department of Physics, via Bassi 6, 27100 Pavia (Italy); Piersimoni, P. [Division of Radiation Research, Loma Linda University, Loma Linda, CA 92354 (United States); Riccardi, C.; Rimoldi, A.; Tamborini, A. [University of Pavia-Department of Physics, via Bassi 6, 27100 Pavia (Italy); INFN Section of Pavia, via Bassi 6, 27100 Pavia (Italy); Ciocca, M. [Medical Physics Unit, Centro Nazionale di Adroterapia Oncologica - CNAO Foundation, Strada Campeggi 53, 27100 Pavia (Italy)

    2015-07-01

    The aim of this work is to validate the Geant4 application reproducing the CNAO (National Centre for Oncological Hadrontherapy) beamline and to study of a possible use of carbon ion pencil beams for the treatment of ocular melanomas at the CNAO Centre. The promising aspect of carbon ions radiotherapy for the treatment of this disease lies in its superior relative radiobiological effectiveness (RBE). The Monte Carlo Geant4 toolkit is used to simulate the complete CNAO extraction beamline, with the active and passive components along it. A human eye modeled detector, including a realistic target tumor volume, is used as target. Cross check with previous studies at CNAO using protons allows comparisons on possible benefits on using such a technique with respect to proton beams. Before the eye-detector irradiation a validation of the Geant4 simulation with CNAO experimental data is carried out with both carbon ions and protons. Important beam parameters such as the transverse FWHM and scanned radiation field 's uniformity are tested within the simulation and compared with experimental measurements at CNAO Centre. The physical processes involved in secondary particles generation by carbon ions and protons in the eye-detector are reproduced to take into account the additional dose to the primary beam given to irradiated eye's tissues. A study of beam shaping is carried out to produce a uniform 3D dose distribution (shaped on the tumor) by the use of a spread out Bragg peak. The eye-detector is then irradiated through a two dimensional transverse beam scan at different depths. In the use case the eye-detector is rotated of an angle of 40 deg. in the vertical direction, in order to mis-align the tumor from healthy tissues in front of it. The treatment uniformity on the tumor in the eye-detector is tested. For a more quantitative description of the deposited dose in the eye-detector and for the evaluation of the ratio between the dose deposited in the tumor and

  16. Creation of a Geant4 Muon Tomography Package for Imaging of Nuclear Fuel in Dry Cask Storage

    Energy Technology Data Exchange (ETDEWEB)

    Tsoukalas, Lefteri H. [Purdue Univ., West Lafayette, IN (United States)

    2016-03-01

    This is the final report of the NEUP project “Creation of a Geant4 Muon Tomography Package for Imaging of Nuclear Fuel in Dry Cask Storage”, DE-NE0000695. The project started on December 1, 2013 and this report covers the period December 1, 2013 through November 30, 2015. The project was successfully completed and this report provides an overview of the main achievements, results and findings throughout the duration of the project. Additional details can be found in the main body of this report and on the individual Quarterly Reports and associated Deliverables of the project, uploaded in PICS-NE.

  17. GEANT4 simulation and evaluation of a time-of-flight spectrometer for nuclear cross section measurements in particle therapy

    International Nuclear Information System (INIS)

    Gruenwald, Oxana

    2011-01-01

    In 2007 a new project has been launched in a cooperation between the RWTH Aachen Physics Department, the University Hospital Aachen and the Philips Research Laboratories. The project aim is to validate and improve GEANT4 nuclear interaction models for use in proton and ion therapy. The method chosen here is the measurement of nuclear reaction cross sections which will not only provide a comparison to the simulation but will also allow to improve some of the parameters in the nuclear models. In the first phase of the project 200 MeV protons are used as a projectile in combination with a thin graphite target. For use in particle therapy the excitation functions of the most frequently produced isotopes need to be measured with an accuracy of 10% or less. For this purpose a dedicated detector system has been designed and implemented in GEANT4. The detection of target fragments produced by protons in graphite is achieved via time-of-flight spectrometry. In the setup presented here the primary beam first hits the Start detector and initiates the time-of-flight measurement before it passes through the apertures of two Veto detectors and impinges on the target. Successively, the secondary particles emanating from the target travel a short distance of 70/80 cm through vacuum (0.1 mbar) before they hit one of the 20 Stop detectors which end the time-of-flight measurement and record the energy deposited by the particle. The dissertation at hand describes the underlying detector concept and presents a detailed GEANT4 simulation of the setup which allows to evaluate the detector performance with respect to target fragment identification at a projectile energy of 200 MeV. At first, correlations of time-of-flight and energy deposition are built from simulated data and are subsequently used to reconstruct mass spectra of the detected fragments. Such influences on the detection performance as the target thickness, the residual pressure within the detector chamber, the Veto system

  18. GEANT4 simulation and evaluation of a time-of-flight spectrometer for nuclear cross section measurements in particle therapy

    Energy Technology Data Exchange (ETDEWEB)

    Gruenwald, Oxana

    2011-06-08

    In 2007 a new project has been launched in a cooperation between the RWTH Aachen Physics Department, the University Hospital Aachen and the Philips Research Laboratories. The project aim is to validate and improve GEANT4 nuclear interaction models for use in proton and ion therapy. The method chosen here is the measurement of nuclear reaction cross sections which will not only provide a comparison to the simulation but will also allow to improve some of the parameters in the nuclear models. In the first phase of the project 200 MeV protons are used as a projectile in combination with a thin graphite target. For use in particle therapy the excitation functions of the most frequently produced isotopes need to be measured with an accuracy of 10% or less. For this purpose a dedicated detector system has been designed and implemented in GEANT4. The detection of target fragments produced by protons in graphite is achieved via time-of-flight spectrometry. In the setup presented here the primary beam first hits the Start detector and initiates the time-of-flight measurement before it passes through the apertures of two Veto detectors and impinges on the target. Successively, the secondary particles emanating from the target travel a short distance of 70/80 cm through vacuum (0.1 mbar) before they hit one of the 20 Stop detectors which end the time-of-flight measurement and record the energy deposited by the particle. The dissertation at hand describes the underlying detector concept and presents a detailed GEANT4 simulation of the setup which allows to evaluate the detector performance with respect to target fragment identification at a projectile energy of 200 MeV. At first, correlations of time-of-flight and energy deposition are built from simulated data and are subsequently used to reconstruct mass spectra of the detected fragments. Such influences on the detection performance as the target thickness, the residual pressure within the detector chamber, the Veto system

  19. Modelling of the dose-rate variations with depth in the Martian regolith using GEANT4

    International Nuclear Information System (INIS)

    Morthekai, P.; Jain, M.; Dartnell, L.; Murray, A.S.; Botter-Jensen, L.; Desorgher, L.

    2007-01-01

    The environmental radiation field at the Martian surface consists mainly of Galactic Cosmic Rays (GCR) and charged particles ejected during the Solar Particle Events (SPE). Interactions between these radiation fluxes and the regolith result in a complex radiation field that varies both as a function of depth and time and can only be quantified using radiation transport models. We first describe here the main issues and constraints in deriving Martian dose rates. Preliminary results, obtained using the GEANT4 Monte Carlo simulation tool kit, suggest the surface dose rate is ∼63 mGy a -1 during quiet periods in solar activity. The accuracy of the model predictions has been tested by comparison with published observations of cosmic ray dose-rate variation in the Earth's atmosphere

  20. Geant4 simulation of ion chambers response to 60Co spectrum of LNMRI/IRD Shepherd 81-14D Radiator

    Science.gov (United States)

    Queiroz Filho, P. P.; Da Silva, C. N. M.

    2018-03-01

    The National Ionizing Radiation Metrology Laboratory of the Radioprotection and Dosimetry Institute (LNMRI / IRD) has recently acquired a Shepherd 81-14D Radiator. In this work we simulate, using Geant4, the behavior with the inverse square law radiation for 3 models of PTW spherical chambers used in radioprotection, a relevant information to planning the measurements. We did the corrections for the attenuation and scattering in the air for each distance, where we used the 60Co spectrum simulated previously.

  1. Modeling the tagged-neutron UXO identification technique using the Geant4 toolkit

    International Nuclear Information System (INIS)

    Zhou, Y.; Zhu, X.; Wang, Y.; Mitra, S.

    2012-01-01

    It is proposed to use 14 MeV neutrons tagged by the associated particle neutron time-of-flight technique (APnTOF) to identify the fillers of unexploded ordnances (UXO) by characterizing their carbon, nitrogen and oxygen contents. To facilitate the design and construction of a prototype system, a preliminary simulation model was developed, using the Geant4 toolkit. This work established the toolkit environment for (a) generating tagged neutrons, (b) their transport and interactions within a sample to induce emission and detection of characteristic gamma-rays, and (c) 2D and 3D-image reconstruction of the interrogated object using the neutron and gamma-ray time-of-flight information. Using the modeling, this article demonstrates the novelty of the tagged-neutron approach for extracting useful signals with high signal-to-background discrimination of an object-of-interest from that of its environment. Simulations indicated that an UXO filled with the RDX explosive, hexogen (C 3 H 6 O 6 N 6 ), can be identified to a depth of 20 cm when buried in soil. (author)

  2. Reaction Cross Section Calculations in Neutron Induced Reactions and GEANT4 Simulation of Hadronic Interactions for the Reactor Moderator Material BeO

    Directory of Open Access Journals (Sweden)

    Veli ÇAPALI

    2016-05-01

    Full Text Available BeO is one of the most common moderator material for neutron moderation; due to its high density, neutron capture cross section and physical-chemical properties that provides usage at elevated temperatures. As it’s known, for various applications in the field of reactor design and neutron capture, reaction cross–section data are required. The cross–sections of (n,α, (n,2n, (n,t, (n,EL and (n,TOT reactions for 9Be and 16O nuclei have been calculated by using TALYS 1.6 Two Component Exciton model and EMPIRE 3.2 Exciton model in this study. Hadronic interactions of low energetic neutrons and generated isotopes–particles have been investigated for a situation in which BeO was used as a neutron moderator by using GEANT4, which is a powerful simulation software. In addition, energy deposition along BeO material has been obtained. Results from performed calculations were compared with the experimental nuclear reaction data exist in EXFOR.

  3. Simulations of the Response of the Cluster Detector/Scintillator Wall for the 4π facility at SIS/ESR using the GEANT Detector program

    International Nuclear Information System (INIS)

    Herrmann, N.; Maguire, C.F.; Cerruti, C.; Coffin, J.P.; Fintz, P.; Guillaume, G.; Jundt, F.; Rami, F.; Tezkratt, R.; Wagner, P.

    1990-01-01

    The expected response of the cluster detector/scintillator wall of the SIS/ESR 4π facility has been investigated with the use of the GEANT detector program and the FREESCO event generator code. Results are presented and discussed. It is shown in particular that the efficiency of the track reconstruction method should be acceptable

  4. Simulation Loop between CAD systems, Geant4 and GeoModel: Implementation and Results

    CERN Document Server

    Sharmazanashvili, Alexander; The ATLAS collaboration

    2015-01-01

    Data_vs_MonteCarlo discrepancy is one of the most important field of investigation for ATLAS simulation studies. There are several reasons of above mentioned discrepancies but primary interest is falling on geometry studies and investigation of how geometry descriptions of detector in simulation adequately representing “as-built” descriptions. Shapes consistency and detalization is not important while adequateness of volumes and weights of detector components are essential for tracking. There are 2 main reasons of faults of geometry descriptions in simulation: 1/ Inconsistency to “as-built” geometry descriptions; 2/Internal inaccuracies of transactions added by simulation packages itself. Georgian Engineering team developed hub on the base of CATIA platform and several tools enabling to read in CATIA different descriptions used by simulation packages, like XML/Persint->CATIA; IV/VP1->CATIA; GeoModel->CATIA; Geant4->CATIA. As a result it becomes possible to compare different descriptions with each othe...

  5. Geant4 simulation of the CERN-EU high-energy reference field (CERF) facility.

    Science.gov (United States)

    Prokopovich, D A; Reinhard, M I; Cornelius, I M; Rosenfeld, A B

    2010-09-01

    The CERN-EU high-energy reference field facility is used for testing and calibrating both active and passive radiation dosemeters for radiation protection applications in space and aviation. Through a combination of a primary particle beam, target and a suitable designed shielding configuration, the facility is able to reproduce the neutron component of the high altitude radiation field relevant to the jet aviation industry. Simulations of the facility using the GEANT4 (GEometry ANd Tracking) toolkit provide an improved understanding of the neutron particle fluence as well as the particle fluence of other radiation components present. The secondary particle fluence as a function of the primary particle fluence incident on the target and the associated dose equivalent rates were determined at the 20 designated irradiation positions available at the facility. Comparisons of the simulated results with previously published simulations obtained using the FLUKA Monte Carlo code, as well as with experimental results of the neutron fluence obtained with a Bonner sphere spectrometer, are made.

  6. Quantification of the validity of simulations based on Geant4 and FLUKA for photo-nuclear interactions in the high energy range

    Science.gov (United States)

    Quintieri, Lina; Pia, Maria Grazia; Augelli, Mauro; Saracco, Paolo; Capogni, Marco; Guarnieri, Guido

    2017-09-01

    Photo-nuclear interactions are relevant in many research fields of both fundamental and applied physics and, for this reason, accurate Monte Carlo simulations of photo-nuclear interactions can provide a valuable and indispensable support in a wide range of applications (i.e from the optimisation of photo-neutron source target to the dosimetric estimation in high energy accelerator, etc). Unfortunately, few experimental photo-nuclear data are available above 100 MeV, so that, in the high energy range (from hundreds of MeV up to GeV scale), the code predictions are based on physical models. The aim of this work is to compare the predictions of relevant observables involving photon-nuclear interaction modelling, obtained with GEANT4 and FLUKA, to experimental data (if available), in order to assess the code estimation reliability, over a wide energy range. In particular, the comparison of the estimated photo-neutron yields and energy spectra with the experimental results of the n@BTF experiment (carried out at the Beam Test Facility of DaΦne collider, in Frascati, Italy) is here reported and discussed. Moreover, the preliminary results of the comparison of the cross sections used in the codes with the"evaluated' data recommended by the IAEA are also presented for some selected cases (W, Pb, Zn).

  7. Validation of Geant4 fragmentation for Heavy Ion Therapy

    Science.gov (United States)

    Bolst, David; Cirrone, Giuseppe A. P.; Cuttone, Giacomo; Folger, Gunter; Incerti, Sebastien; Ivanchenko, Vladimir; Koi, Tatsumi; Mancusi, Davide; Pandola, Luciano; Romano, Francesco; Rosenfeld, Anatoly B.; Guatelli, Susanna

    2017-10-01

    12C ion therapy has had growing interest in recent years for its excellent dose conformity. However at therapeutic energies, which can be as high as 400 MeV/u, carbon ions produce secondary fragments. For an incident 400 MeV/u 12C ion beam, ∼ 70 % of the beam will undergo fragmentation before the Bragg Peak. The dosimetric and radiobiological impact of these fragments must be accurately characterised, as it can result in increasing the risk of secondary cancer for the patient as well as altering the relative biological effectiveness. This work investigates the accuracy of three different nuclear fragmentation models available in the Monte Carlo Toolkit Geant4, the Binary Intranuclear Cascade (BIC), the Quantum Molecular Dynamics (QMD) and the Liege Intranuclear Cascade (INCL++). The models were benchmarked against experimental data for a pristine 400 MeV/u 12C beam incident upon a water phantom, including fragment yield, angular and energy distribution. For fragment yields the three alternative models agreed between ∼ 5 and ∼ 35 % with experimental measurements, the QMD using the "Frag" option gave the best agreement for lighter fragments but had reduced agreement for larger fragments. For angular distributions INCL++ was seen to provide the best agreement among the models for all elements with the exception of Hydrogen, while BIC and QMD was seen to produce broader distributions compared to experiment. BIC and QMD performed similar to one another for kinetic energy distributions while INCL++ suffered from producing lower energy distributions compared to the other models and experiment.

  8. Implementation of a model in Geant4 of an accelerator on Cloudmc, a Web application for the parallelization of Monte Carlo simulations in the Cloud

    International Nuclear Information System (INIS)

    Miras del Rio, H.; Jimenez Marrufo, R.; Cortes Giraldo, M. A.; Miras del Rio, C.

    2013-01-01

    This paper describes the implementation in CloudMC of a simulation program MC, based on the code of Geant4, a Siemens Accelerator model Oncor with the intention that in future can be used for calculation of radiation treatments with MC in short periods of time. (Author)

  9. Physics validation of detector simulation tools for LHC

    International Nuclear Information System (INIS)

    Beringer, J.

    2004-01-01

    Extensive studies aimed at validating the physics processes built into the detector simulation tools Geant4 and Fluka are in progress within all Large Hardon Collider (LHC) experiments, within the collaborations developing these tools, and within the LHC Computing Grid (LCG) Simulation Physics Validation Project, which has become the primary forum for these activities. This work includes detailed comparisons with test beam data, as well as benchmark studies of simple geometries and materials with single incident particles of various energies for which experimental data is available. We give an overview of these validation activities with emphasis on the latest results

  10. Stochastic optimization of GeantV code by use of genetic algorithms

    Science.gov (United States)

    Amadio, G.; Apostolakis, J.; Bandieramonte, M.; Behera, S. P.; Brun, R.; Canal, P.; Carminati, F.; Cosmo, G.; Duhem, L.; Elvira, D.; Folger, G.; Gheata, A.; Gheata, M.; Goulas, I.; Hariri, F.; Jun, S. Y.; Konstantinov, D.; Kumawat, H.; Ivantchenko, V.; Lima, G.; Nikitina, T.; Novak, M.; Pokorski, W.; Ribon, A.; Seghal, R.; Shadura, O.; Vallecorsa, S.; Wenzel, S.

    2017-10-01

    GeantV is a complex system based on the interaction of different modules needed for detector simulation, which include transport of particles in fields, physics models simulating their interactions with matter and a geometrical modeler library for describing the detector and locating the particles and computing the path length to the current volume boundary. The GeantV project is recasting the classical simulation approach to get maximum benefit from SIMD/MIMD computational architectures and highly massive parallel systems. This involves finding the appropriate balance between several aspects influencing computational performance (floating-point performance, usage of off-chip memory bandwidth, specification of cache hierarchy, etc.) and handling a large number of program parameters that have to be optimized to achieve the best simulation throughput. This optimization task can be treated as a black-box optimization problem, which requires searching the optimum set of parameters using only point-wise function evaluations. The goal of this study is to provide a mechanism for optimizing complex systems (high energy physics particle transport simulations) with the help of genetic algorithms and evolution strategies as tuning procedures for massive parallel simulations. One of the described approaches is based on introducing a specific multivariate analysis operator that could be used in case of resource expensive or time consuming evaluations of fitness functions, in order to speed-up the convergence of the black-box optimization problem.

  11. Geometry simulation and physics with the CMS forward pixel detector

    Energy Technology Data Exchange (ETDEWEB)

    Parashar, N [Purdue University Calumet, Hammond, Indiana (United States)], E-mail: Neeti@fnal.gov

    2008-06-15

    The Forward Pixel Detector of CMS is an integral part of the Tracking system, which will play a key role in addressing the full physics potential of the collected data. It has a very complex geometry that encompasses multilayer structure of its detector modules. This presentation describes the development of geometry simulation for the Forward Pixel Detector. A new geometry package has been developed, which uses the detector description database (DDD) interface for the XML (eXtensive Markup Language) to GEANT simulation. This is necessary for digitization and GEANT4 reconstruction software for tracking. The expected physics performance is also discussed.

  12. Geometry simulation and physics with the CMS forward pixel detector

    International Nuclear Information System (INIS)

    Parashar, N

    2008-01-01

    The Forward Pixel Detector of CMS is an integral part of the Tracking system, which will play a key role in addressing the full physics potential of the collected data. It has a very complex geometry that encompasses multilayer structure of its detector modules. This presentation describes the development of geometry simulation for the Forward Pixel Detector. A new geometry package has been developed, which uses the detector description database (DDD) interface for the XML (eXtensive Markup Language) to GEANT simulation. This is necessary for digitization and GEANT4 reconstruction software for tracking. The expected physics performance is also discussed

  13. LCDD: A complete detector description package

    Energy Technology Data Exchange (ETDEWEB)

    Graf, Norman, E-mail: Norman.Graf@slac.stanford.edu; McCormick, Jeremy, E-mail: Jeremy.McCormick@slac.stanford.edu

    2015-07-21

    LCDD has been developed to provide a complete detector description package for physics detector simulations using Geant4. All aspects of the experimental setup, such as the physical geometry, magnetic fields, and sensitive detector readouts, as well as control of the physics simulations, such as physics processes, interaction models and kinematic limits, are defined at runtime. Users are therefore able to concentrate on the design of the detector system without having to master the intricacies of C++ programming or being proficient in setting up their own Geant4 application. We describe both the XML-based file format and the processors which communicate this information to the underlying Geant4 simulation toolkit.

  14. Analysis of Relative Biological Effectiveness of Proton Beams and Isoeffective Dose Profiles Using Geant4

    Directory of Open Access Journals (Sweden)

    Hosseini M. A.

    2017-06-01

    Full Text Available Background: The assessment of RBE quantity in the treatment of cancer tumors with proton beams in treatment planning systems (TPS is of high significance. Given the significance of the issue and the studies conducted in the literature, this quantity is fixed and is taken as equal to 1.1. Objective: The main objective of this study was to assess RBE quantity of proton beams and their variations in different depths of the tumor. This dependency makes RBE values used in TPS no longer be fixed as they depend on the depth of the tumor and therefore this dependency causes some changes in the physical dose profile. Materials and Methods: The energy spectrum of protons was measured at various depths of the tumor using proton beam simulations and well as the complete simulation of a cell to a pair of DNA bases through Monte Carlo GEANT4. The resulting energy spectrum was used to estimate the number of double-strand breaks generated in cells. Finally, RBE values were calculated in terms of the penetration depth in the tumor. Results and Conclusion: The simulation results show that the RBE value not fixed terms of the depth of the tumor and it differs from the clinical value of 1.1 at the end of the dose profile and this will lead to a non-uniform absorbed dose profile. Therefore, to create a uniform impact dose area, deep-finishing systems need to be designed by taking into account deep RBE values.

  15. Testable physics by design

    International Nuclear Information System (INIS)

    Choi, Chansoo; Han, Min Cheol; Kim, Chan Hyeong; Kim, Sung Hun; Hoff, Gabriela; Pia, Maria Grazia; Saracco, Paolo; Weidenspointner, Georg

    2015-01-01

    The ability to test scientific software needs to be supported by adequate software design. Legacy software systems are often characterized by the difficulty to test parts of the software, mainly due to existing dependencies on other parts. Methods to improve the testability of physics software are discussed, along with open issues specific to physics software for Monte Carlo particle transport. The discussion is supported by examples drawn from the experience with validating Geant4 physics. (paper)

  16. Geant4 simulation of ion chambers response to {sup 60}Co spectrum of LNMRI/IRD Shepherd 81-14D Radiator

    Energy Technology Data Exchange (ETDEWEB)

    Queiroz Filho, P.P.; Silva, C.N.M. da, E-mail: queiroz@ird.gov.br [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    The National Ionizing Radiation Metrology Laboratory of the Radioprotection and Dosimetry Institute (LNMRI / IRD) has recently acquired a Shepherd 81-14D Radiator. In this work we simulate, using Geant4, the behavior with the inverse square law radiation of the distance for 3 models of PTW spherical chambers used in radioprotection, a relevant information to planning the measurements. We did the corrections for the attenuation and scattering in the air for each distance, where we used the {sup 60}Co spectrum simulated previously. (author)

  17. First results of saturation curve measurements of heat-resistant steel using GEANT4 and MCNP5 codes

    International Nuclear Information System (INIS)

    Hoang, Duc-Tam; Tran, Thien-Thanh; Le, Bao-Tran; Vo, Hoang-Nguyen; Chau, Van-Tao; Tran, Kim-Tuyet; Huynh, Dinh-Chuong

    2015-01-01

    A gamma backscattering technique is applied to calculate the saturation curve and the effective mass attenuation coefficient of material. A NaI(Tl) detector collimated by collimator of large diameter is modeled by Monte Carlo technique using both MCNP5 and GEANT4 codes. The result shows a good agreement in response function of the scattering spectra for the two codes. Based on such spectra, the saturation curve of heat-resistant steel is determined. The results represent a strong confirmation that it is appropriate to use the detector collimator of large diameter to obtain the scattering spectra and this work is also the basis of experimental set-up for determining the thickness of material. (author)

  18. Comparison of Geant4 multiple Coulomb scattering models with theory for radiotherapy protons.

    Science.gov (United States)

    Makarova, Anastasia; Gottschalk, Bernard; Sauerwein, Wolfgang

    2017-07-06

    Usually, Monte Carlo models are validated against experimental data. However, models of multiple Coulomb scattering (MCS) in the Gaussian approximation are exceptional in that we have theories which are probably more accurate than the experiments which have, so far, been done to test them. In problems directly sensitive to the distribution of angles leaving the target, the relevant theory is the Molière/Fano/Hanson variant of Molière theory (Gottschalk et al 1993 Nucl. Instrum. Methods Phys. Res. B 74 467-90). For transverse spreading of the beam in the target itself, the theory of Preston and Koehler (Gottschalk (2012 arXiv:1204.4470)) holds. Therefore, in this paper we compare Geant4 simulations, using the Urban and Wentzel models of MCS, with theory rather than experiment, revealing trends which would otherwise be obscured by experimental scatter. For medium-energy (radiotherapy) protons, and low-Z (water-like) target materials, Wentzel appears to be better than Urban in simulating the distribution of outgoing angles. For beam spreading in the target itself, the two models are essentially equal.

  19. BCD/CPS: An event-level GEANT3 parallelization via CPS

    International Nuclear Information System (INIS)

    Roberts, L.A.

    1991-04-01

    BCD/CPS is an implementation of the Bottom Collider Detector GEANT3 simulation for CPS processor ranches. BCD/CPS demonstrates some of the capabilities of event-parallel applications applicable to current SSC detector simulations using the CPS and CZ/CPS communications protocols. Design, implementation and usage of the BCD/CPS simulation are presented along with extensive source listings for novice GEANT3/CPS programmers. 11 refs

  20. Modeling the TrueBeam linac using a CAD to Geant4 geometry implementation: Dose and IAEA-compliant phase space calculations

    International Nuclear Information System (INIS)

    Constantin, Magdalena; Perl, Joseph; LoSasso, Tom; Salop, Arthur; Whittum, David; Narula, Anisha; Svatos, Michelle; Keall, Paul J.

    2011-01-01

    Purpose: To create an accurate 6 MV Monte Carlo simulation phase space for the Varian TrueBeam treatment head geometry imported from cad (computer aided design) without adjusting the input electron phase space parameters. Methods: geant4 v4.9.2.p01 was employed to simulate the 6 MV beam treatment head geometry of the Varian TrueBeam linac. The electron tracks in the linear accelerator were simulated with Parmela, and the obtained electron phase space was used as an input to the Monte Carlo beam transport and dose calculations. The geometry components are tessellated solids included in geant4 as gdml (generalized dynamic markup language) files obtained via STEP (standard for the exchange of product) export from Pro/Engineering, followed by STEP import in Fastrad, a STEP-gdml converter. The linac has a compact treatment head and the small space between the shielding collimator and the divergent arc of the upper jaws forbids the implementation of a plane for storing the phase space. Instead, an IAEA (International Atomic Energy Agency) compliant phase space writer was implemented on a cylindrical surface. The simulation was run in parallel on a 1200 node Linux cluster. The 6 MV dose calculations were performed for field sizes varying from 4 x 4 to 40 x 40 cm 2 . The voxel size for the 60x60x40 cm 3 water phantom was 4x4x4 mm 3 . For the 10x10 cm 2 field, surface buildup calculations were performed using 4x4x2 mm 3 voxels within 20 mm of the surface. Results: For the depth dose curves, 98% of the calculated data points agree within 2% with the experimental measurements for depths between 2 and 40 cm. For depths between 5 and 30 cm, agreement within 1% is obtained for 99% (4x4), 95% (10x10), 94% (20x20 and 30x30), and 89% (40x40) of the data points, respectively. In the buildup region, the agreement is within 2%, except at 1 mm depth where the deviation is 5% for the 10x10 cm 2 open field. For the lateral dose profiles, within the field size for fields up to 30x30 cm 2

  1. Modeling the TrueBeam linac using a CAD to Geant4 geometry implementation: Dose and IAEA-compliant phase space calculations

    Energy Technology Data Exchange (ETDEWEB)

    Constantin, Magdalena; Perl, Joseph; LoSasso, Tom; Salop, Arthur; Whittum, David; Narula, Anisha; Svatos, Michelle; Keall, Paul J. [Department of Radiation Oncology, Radiation Physics Division, Stanford University, Stanford, California 94304 (United States); SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Memorial Sloan-Kettering Cancer Center, New York 10021 (United States); Varian Medical Systems, Inc., Palo Alto, California 94304 (United States); Department of Radiation Oncology, Radiation Physics Division, Stanford University, Stanford, California 94304 (United States)

    2011-07-15

    Purpose: To create an accurate 6 MV Monte Carlo simulation phase space for the Varian TrueBeam treatment head geometry imported from cad (computer aided design) without adjusting the input electron phase space parameters. Methods: geant4 v4.9.2.p01 was employed to simulate the 6 MV beam treatment head geometry of the Varian TrueBeam linac. The electron tracks in the linear accelerator were simulated with Parmela, and the obtained electron phase space was used as an input to the Monte Carlo beam transport and dose calculations. The geometry components are tessellated solids included in geant4 as gdml (generalized dynamic markup language) files obtained via STEP (standard for the exchange of product) export from Pro/Engineering, followed by STEP import in Fastrad, a STEP-gdml converter. The linac has a compact treatment head and the small space between the shielding collimator and the divergent arc of the upper jaws forbids the implementation of a plane for storing the phase space. Instead, an IAEA (International Atomic Energy Agency) compliant phase space writer was implemented on a cylindrical surface. The simulation was run in parallel on a 1200 node Linux cluster. The 6 MV dose calculations were performed for field sizes varying from 4 x 4 to 40 x 40 cm{sup 2}. The voxel size for the 60x60x40 cm{sup 3} water phantom was 4x4x4 mm{sup 3}. For the 10x10 cm{sup 2} field, surface buildup calculations were performed using 4x4x2 mm{sup 3} voxels within 20 mm of the surface. Results: For the depth dose curves, 98% of the calculated data points agree within 2% with the experimental measurements for depths between 2 and 40 cm. For depths between 5 and 30 cm, agreement within 1% is obtained for 99% (4x4), 95% (10x10), 94% (20x20 and 30x30), and 89% (40x40) of the data points, respectively. In the buildup region, the agreement is within 2%, except at 1 mm depth where the deviation is 5% for the 10x10 cm{sup 2} open field. For the lateral dose profiles, within the field size

  2. Modelling physics detectors in a computer aided design system for simulation purposes

    International Nuclear Information System (INIS)

    Ahvenainen, J.; Oksakivi, T.; Vuoskoski, J.

    1995-01-01

    The possibility of transferring physics detector models from computer aided design systems into physics simulation packages like GEANT is receiving increasing attention. The problem of exporting detector models constructed in CAD systems into GEANT is well known. We discuss the problem and describe an application, called DDT, which allows one to design detector models in a CAD system and then transfer the models into GEANT for simulation purposes. (orig.)

  3. Distributed Geant4 simulation in medical and space science applications using DIANE framework and the GRID

    CERN Document Server

    Moscicki, J T; Mantero, A; Pia, M G

    2003-01-01

    Distributed computing is one of the most important trends in IT which has recently gained significance for large-scale scientific applications. Distributed analysis environment (DIANE) is a R&D study, focusing on semiinteractive parallel and remote data analysis and simulation, which has been conducted at CERN. DIANE provides necessary software infrastructure for parallel scientific applications in the master-worker model. Advanced error recovery policies, automatic book-keeping of distributed jobs and on-line monitoring and control tools are provided. DIANE makes a transparent use of a number of different middleware implementations such as load balancing service (LSF, PBS, GRID Resource Broker, Condor) and security service (GSI, Kerberos, openssh). A number of distributed Geant 4 simulations have been deployed and tested, ranging from interactive radiotherapy treatment planning using dedicated clusters in hospitals, to globally-distributed simulations of astrophysics experiments using the European data g...

  4. Physics potential for the measurement of sigma(H nu antinu ̄) x BR(H -->μ+μ-) at a 1.4 TeV CLIC collider

    CERN Document Server

    Milutinovic-Dumbelovic, Gordana; Grefe, Christian; Kacarevic, Goran; Lukic, Strahinja; Pandurovic, Mila; Roloff, Philipp Gerhard; Smiljanic, Ivan

    2015-01-01

    Measurements of Higgs couplings at CLIC will offer the potential for a rich precision phys- ics programme and for the search for physics beyond the Standard Model(SM). The poten- tial for measuring the SM Higgs boson decay into two muons at a 1.4 TeV CLIC collider is addressed in this paper. The study is performed using a full Geant4 detector simulation of the CLIC_ILD detector model, taking into consideration all the relevant physics and beam-induced background processes, as well as the instrumentation of the very forward region to identify high-energy electrons. In this analysis, we show that the branching ratio BR(H-->μ+μ-) times the Higgs production cross-section in W+W- fusion can be measured with 38% statistical accuracy at sqrt(s) = 1.4 TeV assuming an integrated luminosity of 1.5 ab-1 with unpolarised beams. If 80% electron beam polarisation is considered, as planned for CLIC, the statistical uncertainty of the measurement is 27%. Systematic uncertainties are negligible.

  5. Analysis of the dead layer of a detector of germanium with code ultrapure Monte Carlo SWORD-GEANT; Analisis del dead layer de un detector de germanio ultrapuro con el codigo de Monte Carlo SWORDS-GEANT

    Energy Technology Data Exchange (ETDEWEB)

    Gallardo, S.; Querol, A.; Ortiz, J.; Rodenas, J.; Verdu, G.

    2014-07-01

    In this paper the use of Monte Carlo code SWORD-GEANT is proposed to simulate an ultra pure germanium detector High Purity Germanium detector (HPGe) detector ORTEC specifically GMX40P4, coaxial geometry. (Author)

  6. Energy Response and Longitudinal Shower Profiles Measured in CMS HCAL and Comparison With Geant4

    CERN Document Server

    Baiatian, G; Emeliantchik, Igor; Massolov, V; Shumeiko, Nikolai; Stefanovich, R; Damgov, Jordan; Dimitrov, Lubomir; Genchev, Vladimir; Piperov, Stefan; Vankov, Ivan; Litov, Leander; Bencze, Gyorgy; Laszlo, Andras; Pal, Andras; Vesztergombi, Gyorgy; Zálán, Peter; Fenyvesi, Andras; Bawa, Harinder Singh; Beri, Suman Bala; Bhatnagar, Vipin; Kaur, Manjit; Kohli, Jatinder Mohan; Kumar, Arun; Singh, Jas Bir; Acharya, Bannaje Sripathi; Banerjee, Sunanda; Banerjee, Sudeshna; Chendvankar, Sanjay; Dugad, Shashikant; Kalmani, Suresh Devendrappa; Katta, S; Mazumdar, Kajari; Mondal, Naba Kumar; Nagaraj, P; Patil, Mandakini Ravindra; Reddy, L; Satyanarayana, B; Sharma, Seema; Sudhakar, Katta; Verma, Piyush; Hashemi, Majid; Mohammadi-Najafabadi, M; Paktinat, S; Golutvin, Igor; Kalagin, Vladimir; Kosarev, Ivan; Ladygin, Vladimir; Mescheryakov, G; Moissenz, P; Petrosian, A; Sergeyev, S; Smirnov, Vitaly; Vishnevskiy, Alexander; Volodko, Anton; Zarubin, Anatoli; Gavrilov, Vladimir; Gershtein, Yuri; Ilyina, N; Kaftanov, Vitali; Kisselevich, I; Kolossov, V; Krokhotin, Andrey; Kuleshov, Sergey; Litvintsev, Dmitri; Ulyanov, A; Safronov, Grigory; Semenov, Sergey; Stolin, Viatcheslav; Demianov, A; Gribushin, Andrey; Kodolova, Olga; Petrushanko, Sergey; Sarycheva, Ludmila; Teplov, V; Vardanyan, Irina; Yershov, A; Abramov, Victor; Goncharov, Petr; Kalinin, Alexey; Khmelnikov, Alexander; Korablev, Andrey; Korneev, Yury; Krinitsyn, Alexander; Kryshkin, V; Lukanin, Vladimir; Pikalov, Vladimir; Ryazanov, Anton; Talov, Vladimir; Turchanovich, L; Volkov, Alexey; Camporesi, Tiziano; De Visser, Theo; Vlassov, E; Aydin, Sezgin; Bakirci, Mustafa Numan; Cerci, Salim; Dumanoglu, Isa; Eskut, Eda; Kayis-Topaksu, A; Koylu, S; Kurt, Pelin; Onengüt, G; Ozkurt, Halil; Polatoz, A; Sogut, Kenan; Topakli, Huseyin; Vergili, Mehmet; Yetkin, Taylan; Cankocak, Kerem; Esendemir, Akif; Gamsizkan, Halil; Güler, M; Ozkan, Cigdem; Sekmen, Sezen; Serin-Zeyrek, M; Sever, Ramazan; Yazgan, Efe; Zeyrek, Mehmet; Deliomeroglu, Mehmet; Dindar, Kamile; Gülmez, Erhan; Isiksal, Engin; Kaya, Mithat; Ozkorucuklu, Suat; Levchuk, Leonid; Sorokin, Pavel; Senchishin, V; Hauptman, John M; Abdullin, Salavat; Elias, John E; Elvira, D; Freeman, Jim; Green, Dan; Los, Serguei; O'Dell, Vivian; Ronzhin, Anatoly; Suzuki, Ichiro; Vidal, Richard; Whitmore, Juliana; Arcidy, M; Hazen, Eric; Heering, Arjan Hendrix; Lawlor, C; Lazic, Dragoslav; Machado, Emanuel; Rohlf, James; Varela, F; Wu, Shouxiang; Baden, Drew; Bard, Robert; Eno, Sarah Catherine; Grassi, Tullio; Jarvis, Chad; Kellogg, Richard G; Kunori, Shuichi; Mans, Jeremy; Skuja, Andris; Podrasky, V; Sanzeni, Christopher; Winn, Dave; Akgun, Ugur; Ayan, S; Duru, Firdevs; Merlo, Jean-Pierre; Mestvirishvili, Alexi; Miller, Michael; Norbeck, Edwin; Olson, Jonathan; Onel, Yasar; Schmidt, Ianos; Akchurin, Nural; Carrell, Kenneth Wayne; Gumus, Kazim; Kim, Heejong; Spezziga, Mario; Thomas, Ray; Baarmand, Marc M; Mermerkaya, Hamit; Ralich, Robert; Vodopiyanov, Igor; Kramer, Laird; Linn, Stephan; Markowitz, Pete; Cushman, Priscilla; Ma, Yousi; Sherwood, Brian; Cremaldi, Lucien Marcus; Reidy, Jim; Sanders, David A; Karmgard, Daniel John; Ruchti, Randy; Fisher, Wade Cameron; Tully, Christopher; Bodek, Arie; De Barbaro, Pawel; Budd, Howard; Chung, Yeon Sei; Haelen, T; Hagopian, Sharon; Hagopian, Vasken; Johnson, Kurtis F; Barnes, Virgil E; Laasanen, Alvin T

    2007-01-01

    The response of the CMS combined electromagnetic and hadron calorimeter to beams of pions with momenta in the range 5-300 GeV/c has been measured in the H2 test beam at CERN. The raw response with the electromagnetic compartment calibrated to electrons and the hadron compartment calibrated to 300 GeV pions may be represented by sigma = (1.2) sqrt{E} oplus (0.095) E. The fraction of energy visible in the calorimeter ranges from 0.72 at 5 GeV to 0.95 at 300 GeV, indicating a substantial nonlinearity. The intrinsic electron to hadron ratios are fit as a function of energy and found to be in the range 1.3-2.7 for the electromagnetic compartment and 1.4-1.8 for the hadronic compartment. The fits are used to correct the non-linearity of the e pi response to 5% over the entire measured range resulting in a substantially improved resolution at low energy. Longitudinal shower profile have been measured in detail and compared to Geant4 models, LHEP-3.7 and QGSP-2.8. At energies below 30 GeV, the data, LHEP and QGSP are...

  7. Development of a computational system based in the code GEANT4 for dosimetric evaluation in radiotherapy; Desenvolvimento de um sistema computacional baseado no Codigo GEANT4 para avaliacoes dosimetricas em radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Alex Cristovao Holanda de

    2016-10-01

    The incidence of cancer has grown in Brazil, as well as around the world, following the change in the age profile of the population. One of the most important techniques and commonly used in cancer treatment is radiotherapy. Around 60% of new cases of cancer use radiation in at least one phase of treatment. The most used equipment for radiotherapy is a linear accelerator (Linac) which produces electron or X-ray beams in energy range from 5 to 30 MeV. The most appropriate way to irradiate a patient is determined during treatment planning. Currently, treatment planning system (TPS) is the main and the most important tool in the process of planning for radiotherapy. The main objective of this work is to develop a computational system based on the MC code Geant4 for dose evaluations in photon beam radiotherapy. In addition to treatment planning, these dose evaluations can be performed for research and quality control of equipment and TPSs. The computer system, called Quimera, consists of a graphical user interface (qGUI) and three MC applications (qLinacs, qMATphantoms and qNCTphantoms). The qGUI has the function of interface for the MC applications, by creating or editing the input files, running simulations and analyzing the results. The qLinacs is used for modeling and generation of Linac beams (phase space). The qMATphantoms and qNCTphantoms are used for dose calculations in virtual models of physical phantoms and computed tomography (CT) images, respectively. From manufacturer's data, models of a Varian Linac photon beam and a Varian multileaf collimator (MLC) were simulated in the qLinacs. The Linac and MLC modelling were validated using experimental data. qMATphamtoms and qNCTphantoms were validated using IAEA phase spaces. In this first version, the Quimera can be used for research, radiotherapy planning of simple treatments and quality control in photon beam radiotherapy. The MC applications work independent of the qGUI and the qGUI can be used for

  8. Optimization of 6LiF:ZnS(Ag) scintillator light yield using GEANT4

    Science.gov (United States)

    Yehuda-Zada, Y.; Pritchard, K.; Ziegler, J. B.; Cooksey, C.; Siebein, K.; Jackson, M.; Hurlbut, C.; Kadmon, Y.; Cohen, Y.; Ibberson, R. M.; Majkrzak, C. F.; Maliszewskyj, N. C.; Orion, I.; Osovizky, A.

    2018-06-01

    A new cold neutron detector has been developed at the NIST Center for Neutron Research (NCNR) for the CANDoR (Chromatic Analysis Neutron Diffractometer or Reflectometer) project. Geometric and performance constraints dictate that this detector be exceptionally thin (∼ 2 mm). For this reason, the design of the detector consists of a 6LiF:ZnS(Ag) scintillator with embedded wavelength shifting (WLS) fibers. We used the GEANT4 package to simulate neutron capture and light transport in the detector to optimize the composition and arrangement of materials to satisfy the competing requirements of high neutron capture probability and light production and transport. In the process, we have developed a method for predicting light collection and total neutron detection efficiency for different detector configurations. The simulation was performed by adjusting crucial parameters such as the scintillator stoichiometry, light yield, component grain size, WLS fiber geometry, and reflectors at the outside edges of the scintillator volume. Three different detector configurations were fabricated and their test results were correlated with the simulations. Through this correlation we have managed to find a common photon threshold for the different detector configurations which was then used to simulate and predict the efficiencies for many other detector configurations. New detectors that have been fabricated based on simulation results yielding the desired sensitivity of 90% for 3.27 meV (5 Å) cold neutrons. The simulation has proven to be a useful tool by dramatically reducing the development period and the required number of detector prototypes. It can be used to test new designs with different thicknesses and different target neutron energies.

  9. Simulation of silicon microdosimetry spectra in fast neutron therapy using the GEANT4 Monte Carlo toolkit

    International Nuclear Information System (INIS)

    Cornelius, I.M.; Rosenfeld, A.B.

    2003-01-01

    Microdosimetry is used to predict the biological effects of the densely ionizing radiation environments of hadron therapy and space. The creation of a solid state microdosimeter to replace the conventional Tissue Equivalent Proportional Counter (TEPC) is a topic of ongoing research. The Centre for Medical Radiation Physics has been investigating a technique using microscopic arrays of reverse biased PN junctions. A prototype silicon-on-insulator (SOI) microdosimeter was developed and preliminary measurements have been conducted at several hadron therapy facilities. Several factors impede the application of silicon microdosimeters to hadron therapy. One of the major limitations is that of tissue equivalence, ideally the silicon microdosimeter should provide a microdosimetry distribution identical to that of a microscopic volume of tissue. For microdosimetry in neutron fields, such as Fast Neutron Therapy, it is important that products resulting from neutron interactions in the non tissue equivalent sensitive volume do not contribute significantly to the spectrum. Experimental measurements have been conducted at the Gershenson Radiation Oncology Center, Harper Hospital, Detroit by Bradley et al. The aim was to provide a comparison with measurements performed with a TEPC under identical experimental conditions. Monte Carlo based calculations of these measurements were made using the GEANT4 Monte Carlo toolkit. Agreement between experimental and theoretical results was observed. The model illustrated the importance of neutron interactions in the non tissue equivalent sensitive volume and showed this effect to decrease with sensitive volume size as expected. Simulations were also performed for 1 micron cubic silicon sensitive volumes embedded in tissue equivalent material to predict the best case scenario for silicon microdosimetry in Fast Neutron Therapy

  10. Efficiency corrections in determining the 137Cs inventory of environmental soil samples by using relative measurement method and GEANT4 simulations

    International Nuclear Information System (INIS)

    Li, Gang; Liang, Yongfei; Xu, Jiayun; Bai, Lixin

    2015-01-01

    The determination of 137 Cs inventory is widely used to estimate the soil erosion or deposition rate. The generally used method to determine the activity of volumetric samples is the relative measurement method, which employs a calibration standard sample with accurately known activity. This method has great advantages in accuracy and operation only when there is a small difference in elemental composition, sample density and geometry between measuring samples and the calibration standard. Otherwise it needs additional efficiency corrections in the calculating process. The Monte Carlo simulations can handle these correction problems easily with lower financial cost and higher accuracy. This work presents a detailed description to the simulation and calibration procedure for a conventionally used commercial P-type coaxial HPGe detector with cylindrical sample geometry. The effects of sample elemental composition, density and geometry were discussed in detail and calculated in terms of efficiency correction factors. The effect of sample placement was also analyzed, the results indicate that the radioactive nuclides and sample density are not absolutely uniform distributed along the axial direction. At last, a unified binary quadratic functional relationship of efficiency correction factors as a function of sample density and height was obtained by the least square fitting method. This function covers the sample density and height range of 0.8–1.8 g/cm 3 and 3.0–7.25 cm, respectively. The efficiency correction factors calculated by the fitted function are in good agreement with those obtained by the GEANT4 simulations with the determination coefficient value greater than 0.9999. The results obtained in this paper make the above-mentioned relative measurements more accurate and efficient in the routine radioactive analysis of environmental cylindrical soil samples. - Highlights: • Determination of 137 Cs inventory in environmental soil samples by using relative

  11. Simulation of the Production of Secondary Particles from a Neutron Beam on Polyethylene Targets using the GEANT4 Simulation Tool

    CERN Document Server

    Ilgner, C

    2003-01-01

    In view of a beam test of RadFET semiconductor detectors and optically stimulated luminescence (OSL) detectors as on-line dosimeters for radiation monitoring purposes in the caverns of the Large Hadron Collider (LHC) experiments, a simulation on the production of secondary particles from a neutron beam on a polyethylene target was carried out. We describe the yield of recoil protons, scattered neutrons as well as electrons, positrons and photons, when neutrons of an average energy of 20 MeV hit polyethylene targets of several thicknesses. The simulation was carried out using the latest release 5.2 of the GEANT4 detector description and simulation tool, including advanced hadron interaction models.

  12. Simulation of "6"0Co and "1"3"7Csspectra of irradiator Shepherd 81 - 14D do LNMRI/IRD using Geant4

    International Nuclear Information System (INIS)

    Queiroz Filho, P.P.; Cabral, T.S.; Silva, C.N.M. da

    2016-01-01

    In this work it were simulated, using Geant4, the "6"0Co and "1"3"7Cs spectra of the Irradiator Shepherd 81-14D acquired by the National Metrology Laboratory of Ionising Radiation of the Institute of Radiation Protection and Dosimetry ( LNMRI / IRD ), which will be used for calibration in radioprotection. Was checked if photons suffered his first interaction on the source, the structure of the head or the collimators. It was also observed the percentage of occurrence of each type of interaction in such structures. (author)

  13. SM-like Higgs decay into two muons at 1.4 TeV CLIC

    CERN Document Server

    Milutinovic-Dumbelovic, G

    2014-01-01

    The potential for measuring the Standard Model (SM) Higgs boson decay into two muons at a 1.4 TeV CLIC e+e− collider is addressed in this paper, that was presented at ICHEP2014. The study is performed in the full Geant4 detector simulations of CLIC_ILD, taking into consideration all the relevant physics and the beam-induced background processes, as well as the instrumentation of the very forward region to tag forward electrons. In this analysis we show that the branching ratio BR(H-->mu+mu-) times the Higgs production cross-section can be measured with 38% statistical accuracy at √s =1.4 TeV using an integrated luminosity of 1.5 ab-1. This study is part of an ongoing comprehensive Higgs physics benchmark study covering various Higgs production processes and decay modes, currently being carried out to estimate the full Higgs physics potential of CLIC.

  14. Simulation and dosimetric analysis of protons, 4He ions and 12C ions beams for brain neoplasm therapy

    International Nuclear Information System (INIS)

    Santos, Guilherme M.; Mello, Victor Barreto Braga; Mello Neto, Joao R.T. de

    2016-01-01

    This study aims to simulate protons, 4 He ions and 12 C ions beams, radiating the head of an average-sized man with the purpose of treating a hypothalamic tumor. GEANT4 was used to simulate the head (skin, skull and brain), and the beam, giving their characteristics and also the physical processes involved. The results sought herein are graphs of depth for relative dose for each of the three particles incident on the settings mentioned above. (author)

  15. Determination of tungsten target parameters for transmission X-ray tube: A simulation study using Geant4

    Energy Technology Data Exchange (ETDEWEB)

    Nasseri, Mohammad M. [School of Plasma Physics and Nuclear Fusion, Institute of Nuclear Science and Technology (AEOI), Tehran (Iran, Islamic Republic of)

    2016-06-15

    Transmission X-ray tubes based on carbon nanotube have attracted significant attention recently. In most of these tubes, tungsten is used as the target material. In this article, the well-known simulator Geant4 was used to obtain some of the tungsten target parameters. The optimal thickness for maximum production of usable X-rays when the target is exposed to electron beams of different energies was obtained. The linear variation of optimal thickness of the target for different electron energies was also obtained. The data obtained in this study can be used to design X-ray tubes. A beryllium window was considered for the X-ray tube. The X-ray energy spectra at the moment of production and after passing through the target and window for different electron energies in the 30-110 keV range were also obtained. The results obtained show that with a specific thickness, the target material itself can act as filter, which enables generation of X-rays with a limited energy.

  16. Microdosimetry spectra and RBE of 1H, 4He, 7Li and 12C nuclei in water studied with Geant4

    International Nuclear Information System (INIS)

    Burigo, Lucas; Pshenichnov, Igor; Mishustin, Igor; Bleicher, Marcus

    2014-01-01

    A Geant4-based Monte Carlo model for Heavy-Ion Therapy (MCHIT) is used to study radiation fields of 1 H, 4 He, 7 Li and 12 C beams with similar ranges (∼160–180 mm) in water. Microdosimetry spectra are simulated for wall-less and walled Tissue Equivalent Proportional Counters (TEPCs) placed outside or inside a phantom, as in experiments performed, respectively, at NIRS, Japan and GSI, Germany. The impact of fragmentation reactions on microdosimetry spectra is investigated for 4 He, 7 Li and 12 C, and contributions from nuclear fragments of different charge are evaluated for various TEPC positions in the phantom. The microdosimetry spectra measured on the beam axis are well described by MCHIT, in particular, in the vicinity of the Bragg peak. However, the simulated spectra for the walled TEPC far from the beam axis are underestimated. Relative Biological Effectiveness (RBE) of the considered beams is estimated using a modified microdosimetric-kinetic model. Calculations show a similar rise of the RBE up to 2.2–2.9 close to the Bragg peak for helium, lithium and carbon beams compared to the modest values of 1–1.2 at the plateau region. Our results suggest that helium and lithium beams are also promising options for cancer therapy

  17. A computationally efficient moment-preserving Monte Carlo electron transport method with implementation in Geant4

    Energy Technology Data Exchange (ETDEWEB)

    Dixon, D.A., E-mail: ddixon@lanl.gov [Los Alamos National Laboratory, P.O. Box 1663, MS P365, Los Alamos, NM 87545 (United States); Prinja, A.K., E-mail: prinja@unm.edu [Department of Nuclear Engineering, MSC01 1120, 1 University of New Mexico, Albuquerque, NM 87131-0001 (United States); Franke, B.C., E-mail: bcfrank@sandia.gov [Sandia National Laboratories, Albuquerque, NM 87123 (United States)

    2015-09-15

    This paper presents the theoretical development and numerical demonstration of a moment-preserving Monte Carlo electron transport method. Foremost, a full implementation of the moment-preserving (MP) method within the Geant4 particle simulation toolkit is demonstrated. Beyond implementation details, it is shown that the MP method is a viable alternative to the condensed history (CH) method for inclusion in current and future generation transport codes through demonstration of the key features of the method including: systematically controllable accuracy, computational efficiency, mathematical robustness, and versatility. A wide variety of results common to electron transport are presented illustrating the key features of the MP method. In particular, it is possible to achieve accuracy that is statistically indistinguishable from analog Monte Carlo, while remaining up to three orders of magnitude more efficient than analog Monte Carlo simulations. Finally, it is shown that the MP method can be generalized to any applicable analog scattering DCS model by extending previous work on the MP method beyond analytical DCSs to the partial-wave (PW) elastic tabulated DCS data.

  18. Characterisation of a SAGe well detector using GEANT4 and LabSOCS

    Energy Technology Data Exchange (ETDEWEB)

    Britton, R., E-mail: rich.britton@awe.co.uk [AWE, Aldermaston, Reading, Berkshire RG7 4PR (United Kingdom); University of Surrey, Guildford GU2 7XH (United Kingdom); Davies, A.V. [AWE, Aldermaston, Reading, Berkshire RG7 4PR (United Kingdom)

    2015-06-21

    This paper reports on the performance of a recently developed Small Anode Germanium (SAGe) well detector from Canberra Industries. This has been specifically designed to improve the energy resolution of the detector, such that it is comparable to the performance of broad-energy designs while achieving far higher efficiencies. Accurate efficiency characterisations and cascade summing correction factors are crucial for quantifying the radionuclides present in environmental samples, and these were calculated for the complex geometry posed by the well detector using two different methodologies. The first relied on Monte-Carlo simulations based upon the GEANT4 toolkit, and the second utilised Canberra Industries GENIE™ 2000 Gamma Analysis software in conjunction with a LabSOCS™ characterisation. Both were found to be in excellent agreement for all nuclides except for {sup 152}Eu, which presents a known issue in the Canberra software (all nuclides affected by this issue were well documented, and fixes are being developed). The correction factors were used to analyse two fully characterised reference samples, yielding results in good agreement with the accepted activity concentrations. Given the sensitivity of well type geometries to cascade summing, this represents a considerable achievement, and paves the way for the use of the SAGe well detector in analysis of ‘real-world’ environmental samples. With the efficiency increase when using the SAGe well in place of a BEGe, substantial reductions in the Minimum Detectable Activity (MDA) should be achievable for a range of nuclides.

  19. Characterisation of a SAGe well detector using GEANT4 and LabSOCS

    International Nuclear Information System (INIS)

    Britton, R.; Davies, A.V.

    2015-01-01

    This paper reports on the performance of a recently developed Small Anode Germanium (SAGe) well detector from Canberra Industries. This has been specifically designed to improve the energy resolution of the detector, such that it is comparable to the performance of broad-energy designs while achieving far higher efficiencies. Accurate efficiency characterisations and cascade summing correction factors are crucial for quantifying the radionuclides present in environmental samples, and these were calculated for the complex geometry posed by the well detector using two different methodologies. The first relied on Monte-Carlo simulations based upon the GEANT4 toolkit, and the second utilised Canberra Industries GENIE™ 2000 Gamma Analysis software in conjunction with a LabSOCS™ characterisation. Both were found to be in excellent agreement for all nuclides except for 152 Eu, which presents a known issue in the Canberra software (all nuclides affected by this issue were well documented, and fixes are being developed). The correction factors were used to analyse two fully characterised reference samples, yielding results in good agreement with the accepted activity concentrations. Given the sensitivity of well type geometries to cascade summing, this represents a considerable achievement, and paves the way for the use of the SAGe well detector in analysis of ‘real-world’ environmental samples. With the efficiency increase when using the SAGe well in place of a BEGe, substantial reductions in the Minimum Detectable Activity (MDA) should be achievable for a range of nuclides

  20. Compressive effect of the magnetic field on the positron range in commonly used positron emitters simulated using Geant4

    Science.gov (United States)

    Li, Chong; Cao, Xingzhong; Liu, Fuyan; Tang, Haohui; Zhang, Zhiming; Wang, Baoyi; Wei, Long

    2017-11-01

    The compressive effect of a magnetic field on the positron range from commonly used positron emitters in PET (Positron Emission Tomography) was simulated using the Geant4 toolkit with H2O as the environmental material. The compression of the positron range, which was different in the directions parallel and perpendicular to the magnetic field, showed finite final variation of relative change rate versus the magnetic field. The variation greatly depended on the positron-emission energy spectrum in the same medium. Furthermore, the volume of the positron annihilation point was dramatically compressed as the magnetic field was set in the range of 3-6T. It was more prominent for 82Rb , which is generally used as a positron source in PET technology.

  1. Simulation and dosimetric analysis of protons, {sup 4}He ions and {sup 12}C ions beams for brain neoplasm therapy; Simulacao e analise dosimetrica de feixes de protons e ions de {sup 4}He e {sup 12}C em tratamento de tumor cerebral

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Guilherme M.; Mello, Victor Barreto Braga [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil); Mello Neto, Joao R.T. de [Centro Brasileiro de Pesquisas Fisicas (CBPF), Rio de Janeiro, RJ (Brazil)

    2016-07-01

    This study aims to simulate protons, {sup 4}He ions and {sup 12}C ions beams, radiating the head of an average-sized man with the purpose of treating a hypothalamic tumor. GEANT4 was used to simulate the head (skin, skull and brain), and the beam, giving their characteristics and also the physical processes involved. The results sought herein are graphs of depth for relative dose for each of the three particles incident on the settings mentioned above. (author)

  2. New data libraries and physics data management tools

    International Nuclear Information System (INIS)

    Han, M; Kim, C H; Seo, H; Pia, M G; Saracco, P; Augelli, M; Hauf, S; Kuster, M; Moneta, L; Quintieri, L

    2011-01-01

    A number of physics data libraries for Monte Carlo simulation are reviewed. The development of a package for the management of physics data is described: its design, implementation and computational benchmarks. This package improves the data management tools originally developed for Geant4 electromagnetic physics models based on data libraries. The implementation exploits recent evolutions of the C++ libraries appearing in the C++0x draft, which are intended for inclusion in the next C++ ISO Standard. The new tools improve the computational performance of physics data management.

  3. Transfer of physics detector models into CAD systems using modern techniques

    International Nuclear Information System (INIS)

    Dach, M.; Vuoskoski, J.

    1996-01-01

    Designing high energy physics detectors for future experiments requires sophisticated computer aided design and simulation tools. In order to satisfy the future demands in this domain, modern techniques, methods, and standards have to be applied. We present an interface application, designed and implemented using object-oriented techniques, for the widely used GEANT physics simulation package. It converts GEANT detector models into the future industrial standard, STEP. (orig.)

  4. Calibration and GEANT4 Simulations of the Phase II Proton Compute Tomography (pCT) Range Stack Detector

    Energy Technology Data Exchange (ETDEWEB)

    Uzunyan, S. A. [Northern Illinois Univ., DeKalb, IL (United States); Blazey, G. [Northern Illinois Univ., DeKalb, IL (United States); Boi, S. [Northern Illinois Univ., DeKalb, IL (United States); Coutrakon, G. [Northern Illinois Univ., DeKalb, IL (United States); Dyshkant, A. [Northern Illinois Univ., DeKalb, IL (United States); Francis, K. [Northern Illinois Univ., DeKalb, IL (United States); Hedin, D. [Northern Illinois Univ., DeKalb, IL (United States); Johnson, E. [Northern Illinois Univ., DeKalb, IL (United States); Kalnins, J. [Northern Illinois Univ., DeKalb, IL (United States); Zutshi, V. [Northern Illinois Univ., DeKalb, IL (United States); Ford, R. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Rauch, J. E. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Rubinov, P. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Sellberg, G. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Wilson, P. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Naimuddin, M. [Univ. of Delhi, New Delhi (India)

    2015-12-29

    Northern Illinois University in collaboration with Fermi National Accelerator Laboratory (FNAL) and Delhi University has been designing and building a proton CT scanner for applications in proton treatment planning. The Phase II proton CT scanner consists of eight planes of tracking detectors with two X and two Y coordinate measurements both before and after the patient. In addition, a range stack detector consisting of a stack of thin scintillator tiles, arranged in twelve eight-tile frames, is used to determine the water equivalent path length (WEPL) of each track through the patient. The X-Y coordinates and WEPL are required input for image reconstruction software to find the relative (proton) stopping powers (RSP) value of each voxel in the patient and generate a corresponding 3D image. In this Note we describe tests conducted in 2015 at the proton beam at the Central DuPage Hospital in Warrenville, IL, focusing on the range stack calibration procedure and comparisons with the GEANT~4 range stack simulation.

  5. Pramana – Journal of Physics | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    Home; Journals; Pramana – Journal of Physics; Volume 69; Issue 3. Background neutron in the endcap and barrel regions of resistive plate chamber for compact muon solenoid/large hadron collider using GEANT4. J T Rhee M Jamil Christopher Joen Bingzhu Yin Y J Jeon. Research Articles Volume 69 Issue 3 September ...

  6. Measurement and simulation of neutron response function of organic liquid scintillator detector

    International Nuclear Information System (INIS)

    Gohil, M.; Banerjee, K.; Bhattacharya, S.; Bhattacharya, C.; Kundu, S.; Rana, T.K.; Mukherjee, G.; Meena, J.K.; Pandey, R.; Pai, H.; Ghosh, T.K.; Dey, A.; Mukhopadhyay, S.; Pandit, D.; Pal, S.; Banerjee, S.R.; Bandhopadhyay, T.

    2012-01-01

    Response functions of monoenergetic neutrons at various energies, corresponding to a measured neutron energy spectrum have been extracted. The experimental response functions for neutron energies in the range of ∼2-20 MeV have been compared with the respective GEANT4 predictions. It has been found that, there is some discrepancy between the experimental and the GEANT4 simulated neutron response functions at lower pulse height regions, which increases with the increase of neutron energy. This might be due to the incompleteness of the physics processes used in the present GEANT4 simulations. In particular, higher order reaction processes which become more significant at higher energies should be properly taken into account in the calculation of response function.

  7. Geant4 Analysis of a Thermal Neutron Real-Time Imaging System

    Science.gov (United States)

    Datta, Arka; Hawari, Ayman I.

    2017-07-01

    Thermal neutron imaging is a technique for nondestructive testing providing complementary information to X-ray imaging for a wide range of applications in science and engineering. Advancement of electronic imaging systems makes it possible to obtain neutron radiographs in real time. This method requires a scintillator to convert neutrons to optical photons and a charge-coupled device (CCD) camera to detect those photons. Alongside, a well collimated beam which reduces geometrical blurriness, the use of a thin scintillator can improve the spatial resolution significantly. A representative scintillator that has been applied widely for thermal neutron imaging is 6LiF:ZnS (Ag). In this paper, a multiphysics simulation approach for designing thermal neutron imaging system is investigated. The Geant4 code is used to investigate the performance of a thermal neutron imaging system starting with a neutron source and including the production of charged particles and optical photons in the scintillator and their transport for image formation in the detector. The simulation geometry includes the neutron beam collimator and sapphire filter. The 6LiF:ZnS (Ag) scintillator is modeled along with a pixelated detector for image recording. The spatial resolution of the system was obtained as the thickness of the scintillator screen was varied between 50 and 400 μm. The results of the simulation were compared to experimental results, including measurements performed using the PULSTAR nuclear reactor imaging beam, showing good agreement. Using the established model, further examination showed that the resolution contribution of the scintillator screen is correlated with its thickness and the range of the neutron absorption reaction products (i.e., the alpha and triton particles). Consequently, thinner screens exhibit improved spatial resolution. However, this will compromise detection efficiency due to the reduced probability of neutron absorption.

  8. Geant4 Monte Carlo simulation of absorbed dose and radiolysis yields enhancement from a gold nanoparticle under MeV proton irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Tran, H.N., E-mail: tranngochoang@tdt.edu.vn [Division of Nuclear Physics, Ton Duc Thang University, Tan Phong Ward, District 7, Ho Chi Minh City (Viet Nam); Faculty of Applied Sciences, Ton Duc Thang University, Tan Phong Ward, District 7, Ho Chi Minh City (Viet Nam); Karamitros, M. [Notre Dame Radiation Laboratory, University of Notre-Dame, IN 46556 (United States); Ivanchenko, V.N. [Geant4 Associates International Ltd, Hebden Bridge (United Kingdom); Guatelli, S.; McKinnon, S. [Centre For Medical Radiation Physics, University of Wollongong (Australia); Illawarra Health and Medical Research, University of Wollongong, NSW (Australia); Murakami, K.; Sasaki, T.; Okada, S. [Computing Research Center, High Energy Accelerator Organization, KEK, Tsukuba City (Japan); Bordage, M.C. [INSERM, UMR 1037, CRCT, F-31000 Toulouse (France); Univ. Toulouse III-Paul Sabatier, UMR 1037, CRCT, F-31000 Toulouse (France); Francis, Z. [Saint Joseph University, Faculty of Sciences, Department of Physics, Beirut (Lebanon); El Bitar, Z. [Institut Pluridisciplinaire Hubert Curien/IN2P3/CNRS, Strasbourg (France); Bernal, M.A. [Instituto de Física Gleb Wataghin, Universidade Estadual de Campinas, SP (Brazil); Shin, J.I. [Division of Heavy Ion Clinical Research, Korea Institute of Radiological and Medical Science, 75, Nowon-ro, Nowon-gu, Seoul (Korea, Republic of); Lee, S.B. [Proton Therapy Center, National Cancer Center, 323, Ilsan-ro, Ilsandong-gu, Goyang-si, Gyeonggi-do (Korea, Republic of); Barberet, Ph. [Univ. Bordeaux, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); Tran, T.T. [VNUHCM-University of Science (Viet Nam); Brown, J.M.C. [School of Mathematics and Physics, Queen’s University Belfast, Belfast, Northern Ireland (United Kingdom); and others

    2016-04-15

    Gold nanoparticles have been reported as a possible radio-sensitizer agent in radiation therapy due to their ability to increase energy deposition and subsequent direct damage to cells and DNA within their local vicinity. Moreover, this increase in energy deposition also results in an increase of the radiochemical yields. In this work we present, for the first time, an in silico investigation, based on the general purpose Monte Carlo simulation toolkit Geant4, into energy deposition and radical species production around a spherical gold nanoparticle 50 nm in diameter via proton irradiation. Simulations were preformed for incident proton energies ranging from 2 to 170 MeV, which are of interest for clinical proton therapy.

  9. A Geant4-based Simulation to Evaluate the Feasibility of Using Nuclear Resonance Fluorescence (NRF) in Determining Atomic Compositions of Body Tissue in Cancer Diagnostics and Irradiation

    Science.gov (United States)

    Gilbo, Yekaterina; Wijesooriya, Krishni; Liyanage, Nilanga

    2017-01-01

    Customarily applied in homeland security for identifying concealed explosives and chemical weapons, NRF (Nuclear Resonance Fluorescence) may have high potential in determining atomic compositions of body tissue. High energy photons incident on a target excite the target nuclei causing characteristic re-emission of resonance photons. As the nuclei of each isotope have well-defined excitation energies, NRF uniquely indicates the isotopic content of the target. NRF radiation corresponding to nuclear isotopes present in the human body is emitted during radiotherapy based on Bremsstrahlung photons generated in a linear electron accelerator. We have developed a Geant4 simulation in order to help assess NRF capabilities in detecting, mapping, and characterizing tumors. We have imported a digital phantom into the simulation using anatomical data linked to known chemical compositions of various tissues. Work is ongoing to implement the University of Virginia's cancer center treatment setup and patient geometry, and to collect and analyze the simulation's physics quantities to evaluate the potential of NRF for medical imaging applications. Preliminary results will be presented.

  10. Geant4 simulation of clinical proton and carbon ion beams for the treatment of ocular melanomas with the full 3-D pencil beam scanning system

    Energy Technology Data Exchange (ETDEWEB)

    Farina, Edoardo; Riccardi, Cristina; Rimoldi, Adele; Tamborini, Aurora [University of Pavia and the INFN section of Pavia, via Bassi 6, 27100 Pavia (Italy); Piersimoni, Pierluigi [Division of Radiation Research, Loma Linda University, Loma Linda, CA 92354 (United States); Ciocca, Mario [Medical Physics Unit, CNAO Foundation, Strada Campeggi 53, 27100 Pavia (Italy)

    2015-07-01

    This work investigates the possibility to use carbon ion beams delivered with active scanning modality, for the treatment of ocular melanomas at the Centro Nazionale di Adroterapia Oncologica (CNAO) in Pavia. The radiotherapy with carbon ions offers many advantages with respect to the radiotherapy with protons or photons, such as a higher relative radio-biological effectiveness (RBE) and a dose release better localized to the tumor. The Monte Carlo (MC) Geant4 10.00 patch-03 toolkit is used to reproduce the complete CNAO extraction beam line, including all the active and passive components characterizing it. The simulation of proton and carbon ion beams and radiation scanned field is validated against CNAO experimental data. For the irradiation study of the ocular melanoma an eye-detector, representing a model of a human eye, is implemented in the simulation. Each element of the eye is reproduced with its chemical and physical properties. Inside the eye-detector a realistic tumor volume is placed and used as the irradiation target. A comparison between protons and carbon ions eye irradiations allows to study possible treatment benefits if carbon ions are used instead of protons. (authors)

  11. Detector simulations with DD4hep

    CERN Document Server

    AUTHOR|(SzGeCERN)668365; Frank, Markus; Gaede, Frank-Dieter; Lu, Shaojun; Nikiforou, Nikiforos; Sailer, Andre

    2017-01-01

    Detector description is a key component of detector design studies, test beam analyses, and most of particle physics experiments that require the simulation of more and more different detector geometries and event types. This paper describes DD4hep, which is an easy-to-use yet flexible and powerful detector description framework that can be used for detector simulation and also extended to specific needs for a particular working environment. Linear collider detector concepts ILD, SiD and CLICdp as well as detector development collaborations CALICE and FCal have chosen to adopt the DD4hep geometry framework and its DDG4 pathway to Geant4 as its core simulation and reconstruction tools. The DDG4 plugins suite includes a wide variety of input formats, provides access to the Geant4 particle gun or general particles source and allows for handling of Monte Carlo truth information, e.g. by linking hits and the primary particle that caused them, which is indispensable for performance and efficiency studies. An extend...

  12. Detector Simulations with DD4hep

    Science.gov (United States)

    Petrič, M.; Frank, M.; Gaede, F.; Lu, S.; Nikiforou, N.; Sailer, A.

    2017-10-01

    Detector description is a key component of detector design studies, test beam analyses, and most of particle physics experiments that require the simulation of more and more different detector geometries and event types. This paper describes DD4hep, which is an easy-to-use yet flexible and powerful detector description framework that can be used for detector simulation and also extended to specific needs for a particular working environment. Linear collider detector concepts ILD, SiD and CLICdp as well as detector development collaborations CALICE and FCal have chosen to adopt the DD4hep geometry framework and its DDG4 pathway to Geant4 as its core simulation and reconstruction tools. The DDG4 plugins suite includes a wide variety of input formats, provides access to the Geant4 particle gun or general particles source and allows for handling of Monte Carlo truth information, eg. by linking hits and the primary particle that caused them, which is indispensable for performance and efficiency studies. An extendable array of segmentations and sensitive detectors allows the simulation of a wide variety of detector technologies. This paper shows how DD4hep allows to perform complex Geant4 detector simulations without compiling a single line of additional code by providing a palette of sub-detector components that can be combined and configured via compact XML files. Simulation is controlled either completely via the command line or via simple Python steering files interpreted by a Python executable. It also discusses how additional plugins and extensions can be created to increase the functionality.

  13. The A4 project: physics data processing using the Google protocol buffer library

    International Nuclear Information System (INIS)

    Ebke, Johannes; Waller, Peter

    2012-01-01

    In this paper, we present the High Energy Physics data format, processing toolset and analysis library A4, providing fast I/O of structured data using the Google protocol buffer library. The overall goal of A4 is to provide physicists with tools to work efficiently with billions of events, providing not only high speeds, but also automatic metadata handling, a set of UNIX-like tools to operate on A4 files, and powerful and fast histogramming capabilities. At present, A4 is an experimental project, but it has already been used by the authors in preparing physics publications. We give an overview of the individual modules of A4, provide examples of use, and supply a set of basic benchmarks. We compare A4 read performance with the common practice of storing unstructured data in ROOT trees. For the common case of storing a variable number of floating-point numbers per event, speedups in read speed of up to a factor of six are observed.

  14. Linking computer-aided design (CAD) to Geant4-based Monte Carlo simulations for precise implementation of complex treatment head geometries

    International Nuclear Information System (INIS)

    Constantin, Magdalena; Constantin, Dragos E; Keall, Paul J; Narula, Anisha; Svatos, Michelle; Perl, Joseph

    2010-01-01

    Most of the treatment head components of medical linear accelerators used in radiation therapy have complex geometrical shapes. They are typically designed using computer-aided design (CAD) applications. In Monte Carlo simulations of radiotherapy beam transport through the treatment head components, the relevant beam-generating and beam-modifying devices are inserted in the simulation toolkit using geometrical approximations of these components. Depending on their complexity, such approximations may introduce errors that can be propagated throughout the simulation. This drawback can be minimized by exporting a more precise geometry of the linac components from CAD and importing it into the Monte Carlo simulation environment. We present a technique that links three-dimensional CAD drawings of the treatment head components to Geant4 Monte Carlo simulations of dose deposition. (note)

  15. The radiation environment on the surface of Mars - Numerical calculations of the galactic component with GEANT4/PLANETOCOSMICS.

    Science.gov (United States)

    Matthiä, Daniel; Berger, Thomas

    2017-08-01

    Galactic cosmic radiation and secondary particles produced in the interaction with the atmosphere lead to a complex radiation field on the Martian surface. A workshop ("1st Mars Space Radiation Modeling Workshop") organized by the MSL-RAD science team was held in June 2016 in Boulder with the goal to compare models capable to predict this radiation field with each other and measurements from the RAD instrument onboard the curiosity rover taken between November 15, 2015 and January 15, 2016. In this work the results of PLANETOCOSMICS/GEANT4 contributed to the workshop are presented. Calculated secondary particle spectra on the Martian surface are investigated and the radiation field's directionality of the different particles in dependence on the energy is discussed. Omnidirectional particle fluxes are used in combination with fluence to dose conversion factors to calculate absorbed dose rates and dose equivalent rates in a slab of tissue. Copyright © 2017. Published by Elsevier Ltd.

  16. Geant4 simulation of the Elekta XVI kV CBCT unit for accurate description of potential late toxicity effects of image-guided radiotherapy

    International Nuclear Information System (INIS)

    Brochu, F M; Burnet, N G; Jena, R; Plaistow, R; Thomas, S J; Parker, M A

    2014-01-01

    This paper describes the modelisation of the Elekta XVI Cone Beam Computed Tomography (CBCT) machine components with Geant4 and its validation against calibration data taken for two commonly used machine setups. Preliminary dose maps of simulated CBCTs coming from this modelisation work are presented. This study is the first step of a research project, GHOST, aiming to improve the understanding of late toxicity risk in external beam radiotherapy patients by simulating dose depositions integrated from different sources (imaging, treatment beam) over the entire treatment plan. The second cancer risk will then be derived from different models relating irradiation dose and second cancer risk. (paper)

  17. Thick-foils activation technique for neutron spectrum unfolding with the MINUIT routine-Comparison with GEANT4 simulations

    Science.gov (United States)

    Vagena, E.; Theodorou, K.; Stoulos, S.

    2018-04-01

    Neutron activation technique has been applied using a proposed set of twelve thick metal foils (Au, As, Cd, In, Ir, Er, Mn, Ni, Se, Sm, W, Zn) for off-site measurements to obtain the neutron spectrum over a wide energy range (from thermal up to a few MeV) in intense neutron-gamma mixed fields such as around medical Linacs. The unfolding procedure takes into account the activation rates measured using thirteen (n , γ) and two (n , p) reactions without imposing a guess solution-spectrum. The MINUIT minimization routine unfolds a neutron spectrum that is dominated by fast neutrons (70%) peaking at 0.3 MeV, while the thermal peak corresponds to the 15% of the total neutron fluence equal to the epithermal-resonances area. The comparison of the unfolded neutron spectrum against the simulated one with the GEANT4 Monte-Carlo code shows a reasonable agreement within the measurement uncertainties. Therefore, the proposed set of activation thick-foils could be a useful tool in order to determine low flux neutrons spectrum in intense mixed field.

  18. MC 93 - Proceedings of the International Conference on Monte Carlo Simulation in High Energy and Nuclear Physics

    Science.gov (United States)

    Dragovitsch, Peter; Linn, Stephan L.; Burbank, Mimi

    1994-01-01

    Calorimeter Geometry * Simulations with EGS4/PRESTA for Thin Si Sampling Calorimeter * SIBERIA -- Monte Carlo Code for Simulation of Hadron-Nuclei Interactions * CALOR89 Predictions for the Hanging File Test Configurations * Estimation of the Multiple Coulomb Scattering Error for Various Numbers of Radiation Lengths * Monte Carlo Generator for Nuclear Fragmentation Induced by Pion Capture * Calculation and Randomization of Hadron-Nucleus Reaction Cross Section * Developments in GEANT Physics * Status of the MC++ Event Generator Toolkit * Theoretical Overview of QCD Event Generators * Random Numbers? * Simulation of the GEM LKr Barrel Calorimeter Using CALOR89 * Recent Improvement of the EGS4 Code, Implementation of Linearly Polarized Photon Scattering * Interior-Flux Simulation in Enclosures with Electron-Emitting Walls * Some Recent Developments in Global Determinations of Parton Distributions * Summary of the Workshop on Simulating Accelerator Radiation Environments * Simulating the SDC Radiation Background and Activation * Applications of Cluster Monte Carlo Method to Lattice Spin Models * PDFLIB: A Library of All Available Parton Density Functions of the Nucleon, the Pion and the Photon and the Corresponding αs Calculations * DTUJET92: Sampling Hadron Production at Supercolliders * A New Model for Hadronic Interactions at Intermediate Energies for the FLUKA Code * Matrix Generator of Pseudo-Random Numbers * The OPAL Monte Carlo Production System * Monte Carlo Simulation of the Microstrip Gas Counter * Inner Detector Simulations in ATLAS * Simulation and Reconstruction in H1 Liquid Argon Calorimetry * Polarization Decomposition of Fluxes and Kinematics in ep Reactions * Towards Object-Oriented GEANT -- ProdiG Project * Parallel Processing of AMY Detector Simulation on Fujitsu AP1000 * Enigma: An Event Generator for Electron-Photon- or Pion-Induced Events in the ~1 GeV Region * SSCSIM: Development and Use by the Fermilab SDC Group * The GEANT-CALOR Interface

  19. GEANT Monte Carlo simulations for the GREAT spectrometer

    International Nuclear Information System (INIS)

    Andreyev, A.N.; Butler, P.A.; Page, R.D.; Appelbe, D.E.; Jones, G.D.; Joss, D.T.; Herzberg, R.-D.; Regan, P.H.; Simpson, J.; Wadsworth, R.

    2004-01-01

    GEANT Monte Carlo simulations for the recently developed GREAT spectrometer are presented. Some novel applications of the spectrometer for γ-ray, conversion-electron and β-decay spectroscopy are discussed. The conversion-electron spectroscopy of heavy nuclei with strongly converted transitions and the extension of the recoil decay tagging method to β-decaying nuclei are considered in detail

  20. Development of a computational system based in the code GEANT4 for dosimetric evaluation in radiotherapy

    International Nuclear Information System (INIS)

    Oliveira, Alex Cristovao Holanda de

    2016-01-01

    The incidence of cancer has grown in Brazil, as well as around the world, following the change in the age profile of the population. One of the most important techniques and commonly used in cancer treatment is radiotherapy. Around 60% of new cases of cancer use radiation in at least one phase of treatment. The most used equipment for radiotherapy is a linear accelerator (Linac) which produces electron or X-ray beams in energy range from 5 to 30 MeV. The most appropriate way to irradiate a patient is determined during treatment planning. Currently, treatment planning system (TPS) is the main and the most important tool in the process of planning for radiotherapy. The main objective of this work is to develop a computational system based on the MC code Geant4 for dose evaluations in photon beam radiotherapy. In addition to treatment planning, these dose evaluations can be performed for research and quality control of equipment and TPSs. The computer system, called Quimera, consists of a graphical user interface (qGUI) and three MC applications (qLinacs, qMATphantoms and qNCTphantoms). The qGUI has the function of interface for the MC applications, by creating or editing the input files, running simulations and analyzing the results. The qLinacs is used for modeling and generation of Linac beams (phase space). The qMATphantoms and qNCTphantoms are used for dose calculations in virtual models of physical phantoms and computed tomography (CT) images, respectively. From manufacturer's data, models of a Varian Linac photon beam and a Varian multileaf collimator (MLC) were simulated in the qLinacs. The Linac and MLC modelling were validated using experimental data. qMATphamtoms and qNCTphantoms were validated using IAEA phase spaces. In this first version, the Quimera can be used for research, radiotherapy planning of simple treatments and quality control in photon beam radiotherapy. The MC applications work independent of the qGUI and the qGUI can be used for

  1. Implications of virtualization on Grids for high energy physics applications

    CERN Document Server

    Gilbert, L; Newman, R; Iqbal, S; Pepper, R; Celebioglu, O; Hsieh, J; Mashayekhi, V; Cobban, M

    2006-01-01

    The simulations used in the field of high energy physics are compute intensive and exhibit a high level of data parallelism. These features make such simulations ideal candidates for Grid computing. We are taking as an example the GEANT4 detector simulation used for physics studies within the ATLAS experiment at CERN. One key issue in Grid computing is that of network and system security, which can potentially inhibit the widespread use of such simulations. Virtualization provides a feasible solution because it allows the creation of virtual compute nodes in both local and remote compute clusters, thus providing an insulating layer which can play an important role in satisfying the security concerns of all parties involved. However, it has performance implications. This study provides quantitative estimates of the virtualization and hyper-threading overhead for GEANT on commodity clusters. Results show that virtualization has less than 15% run time overhead, and that the best run time (with the non-SMP licens...

  2. GEANT4 simulation diagram showing the architecture of the ATLAS test line: the detectors are positioned to receive the beam from the SPS. A muon particle which enters the magnet and crosses all detectors is shown (blue line).

    CERN Multimedia

    2004-01-01

    GEANT4 simulation diagram showing the architecture of the ATLAS test line: the detectors are positioned to receive the beam from the SPS. A muon particle which enters the magnet and crosses all detectors is shown (blue line).

  3. GEANT4-based full simulation of the PADME experiment at the DAΦNE BTF

    Science.gov (United States)

    Leonardi, E.; Kozhuharov, V.; Raggi, M.; Valente, P.

    2017-10-01

    A possible solution to the dark matter problem postulates that dark particles can interact with Standard Model particles only through a new force mediated by a “portal”. If the new force has a U(1) gauge structure, the “portal” is a massive photon-like vector particle, called dark photon or A‧. The PADME experiment at the DAΦNE Beam-Test Facility (BTF) in Frascati is designed to detect dark photons produced in positron on fixed target annihilations decaying to dark matter (e+e-→γA‧) by measuring the final state missing mass. The experiment will be composed of a thin active diamond target where a 550 MeV positron beam will impinge to produce e+e- annihilation events. The surviving beam will be deflected with a magnet while the photons produced in the annihilation will be measured by a calorimeter composed of BGO crystals. To reject the background from Bremsstrahlung gamma production, a set of segmented plastic scintillator vetoes will be used to detect positrons exiting the target with an energy lower than that of the beam, while a fast small angle calorimeter will be used to reject the e+e-→γγ(γ) background. To optimize the experimental layout in terms of signal acceptance and background rejection, the full layout of the experiment was modelled with the GEANT4 simulation package. In this paper we will describe the details of the simulation and report on the results obtained with the software.

  4. Optimization of a general-purpose, actively scanned proton beamline for ocular treatments: Geant4 simulations.

    Science.gov (United States)

    Piersimoni, Pierluigi; Rimoldi, Adele; Riccardi, Cristina; Pirola, Michele; Molinelli, Silvia; Ciocca, Mario

    2015-03-08

    The Italian National Center for Hadrontherapy (CNAO, Centro Nazionale di Adroterapia Oncologica), a synchrotron-based hospital facility, started the treatment of patients within selected clinical trials in late 2011 and 2012 with actively scanned proton and carbon ion beams, respectively. The activation of a new clinical protocol for the irradiation of uveal melanoma using the existing general-purpose proton beamline is foreseen for late 2014. Beam characteristics and patient treatment setup need to be tuned to meet the specific requirements for such a type of treatment technique. The aim of this study is to optimize the CNAO transport beamline by adding passive components and minimizing air gap to achieve the optimal conditions for ocular tumor irradiation. The CNAO setup with the active and passive components along the transport beamline, as well as a human eye-modeled detector also including a realistic target volume, were simulated using the Monte Carlo Geant4 toolkit. The strong reduction of the air gap between the nozzle and patient skin, as well as the insertion of a range shifter plus a patient-specific brass collimator at a short distance from the eye, were found to be effective tools to be implemented. In perspective, this simulation toolkit could also be used as a benchmark for future developments and testing purposes on commercial treatment planning systems.

  5. Ion therapy for uveal melanoma in new human eye phantom based on GEANT4 toolkit

    Energy Technology Data Exchange (ETDEWEB)

    Mahdipour, Seyed Ali [Physics Department, Hakim Sabzevari University, Sabzevar (Iran, Islamic Republic of); Mowlavi, Ali Asghar, E-mail: amowlavi@hsu.ac.ir [Physics Department, Hakim Sabzevari University, Sabzevar (Iran, Islamic Republic of); ICTP, Associate Federation Scheme, Medical Physics Field, Trieste (Italy)

    2016-07-01

    Radiotherapy with ion beams like proton and carbon has been used for treatment of eye uveal melanoma for many years. In this research, we have developed a new phantom of human eye for Monte Carlo simulation of tumors treatment to use in GEANT4 toolkit. Total depth−dose profiles for the proton, alpha, and carbon incident beams with the same ranges have been calculated in the phantom. Moreover, the deposited energy of the secondary particles for each of the primary beams is calculated. The dose curves are compared for 47.8 MeV proton, 190.1 MeV alpha, and 1060 MeV carbon ions that have the same range in the target region reaching to the center of tumor. The passively scattered spread-out Bragg peak (SOBP) for each incident beam as well as the flux curves of the secondary particles including neutron, gamma, and positron has been calculated and compared for the primary beams. The high sharpness of carbon beam's Bragg peak with low lateral broadening is the benefit of this beam in hadrontherapy but it has disadvantages of dose leakage in the tail after its Bragg peak and high intensity of neutron production. However, proton beam, which has a good conformation with tumor shape owing to the beam broadening caused by scattering, can be a good choice for the large-size tumors.

  6. Ion therapy for uveal melanoma in new human eye phantom based on GEANT4 toolkit

    International Nuclear Information System (INIS)

    Mahdipour, Seyed Ali; Mowlavi, Ali Asghar

    2016-01-01

    Radiotherapy with ion beams like proton and carbon has been used for treatment of eye uveal melanoma for many years. In this research, we have developed a new phantom of human eye for Monte Carlo simulation of tumors treatment to use in GEANT4 toolkit. Total depth−dose profiles for the proton, alpha, and carbon incident beams with the same ranges have been calculated in the phantom. Moreover, the deposited energy of the secondary particles for each of the primary beams is calculated. The dose curves are compared for 47.8 MeV proton, 190.1 MeV alpha, and 1060 MeV carbon ions that have the same range in the target region reaching to the center of tumor. The passively scattered spread-out Bragg peak (SOBP) for each incident beam as well as the flux curves of the secondary particles including neutron, gamma, and positron has been calculated and compared for the primary beams. The high sharpness of carbon beam's Bragg peak with low lateral broadening is the benefit of this beam in hadrontherapy but it has disadvantages of dose leakage in the tail after its Bragg peak and high intensity of neutron production. However, proton beam, which has a good conformation with tumor shape owing to the beam broadening caused by scattering, can be a good choice for the large-size tumors.

  7. Comparison of electron dose-point kernels in water generated by the Monte Carlo codes, PENELOPE, GEANT4, MCNPX, and ETRAN.

    Science.gov (United States)

    Uusijärvi, Helena; Chouin, Nicolas; Bernhardt, Peter; Ferrer, Ludovic; Bardiès, Manuel; Forssell-Aronsson, Eva

    2009-08-01

    Point kernels describe the energy deposited at a certain distance from an isotropic point source and are useful for nuclear medicine dosimetry. They can be used for absorbed-dose calculations for sources of various shapes and are also a useful tool when comparing different Monte Carlo (MC) codes. The aim of this study was to compare point kernels calculated by using the mixed MC code, PENELOPE (v. 2006), with point kernels calculated by using the condensed-history MC codes, ETRAN, GEANT4 (v. 8.2), and MCNPX (v. 2.5.0). Point kernels for electrons with initial energies of 10, 100, 500, and 1 MeV were simulated with PENELOPE. Spherical shells were placed around an isotropic point source at distances from 0 to 1.2 times the continuous-slowing-down-approximation range (R(CSDA)). Detailed (event-by-event) simulations were performed for electrons with initial energies of less than 1 MeV. For 1-MeV electrons, multiple scattering was included for energy losses less than 10 keV. Energy losses greater than 10 keV were simulated in a detailed way. The point kernels generated were used to calculate cellular S-values for monoenergetic electron sources. The point kernels obtained by using PENELOPE and ETRAN were also used to calculate cellular S-values for the high-energy beta-emitter, 90Y, the medium-energy beta-emitter, 177Lu, and the low-energy electron emitter, 103mRh. These S-values were also compared with the Medical Internal Radiation Dose (MIRD) cellular S-values. The greatest differences between the point kernels (mean difference calculated for distances, electrons was 1.4%, 2.5%, and 6.9% for ETRAN, GEANT4, and MCNPX, respectively, compared to PENELOPE, if omitting the S-values when the activity was distributed on the cell surface for 10-keV electrons. The largest difference between the cellular S-values for the radionuclides, between PENELOPE and ETRAN, was seen for 177Lu (1.2%). There were large differences between the MIRD cellular S-values and those obtained from

  8. Simulation framework and XML detector description for the CMS experiment

    CERN Document Server

    Arce, P; Boccali, T; Case, M; de Roeck, A; Lara, V; Liendl, M; Nikitenko, A N; Schröder, M; Strässner, A; Wellisch, H P; Wenzel, H

    2003-01-01

    Currently CMS event simulation is based on GEANT3 while the detector description is built from different sources for simulation and reconstruction. A new simulation framework based on GEANT4 is under development. A full description of the detector is available, and the tuning of the GEANT4 performance and the checking of the ability of the physics processes to describe the detector response is ongoing. Its integration on the CMS mass production system and GRID is also currently under development. The Detector Description Database project aims at providing a common source of information for Simulation, Reconstruction, Analysis, and Visualisation, while allowing for different representations as well as specific information for each application. A functional prototype, based on XML, is already released. Also examples of the integration of DDD in the GEANT4 simulation and in the reconstruction applications are provided.

  9. Electromagnetic Physics Models for Parallel Computing Architectures

    Science.gov (United States)

    Amadio, G.; Ananya, A.; Apostolakis, J.; Aurora, A.; Bandieramonte, M.; Bhattacharyya, A.; Bianchini, C.; Brun, R.; Canal, P.; Carminati, F.; Duhem, L.; Elvira, D.; Gheata, A.; Gheata, M.; Goulas, I.; Iope, R.; Jun, S. Y.; Lima, G.; Mohanty, A.; Nikitina, T.; Novak, M.; Pokorski, W.; Ribon, A.; Seghal, R.; Shadura, O.; Vallecorsa, S.; Wenzel, S.; Zhang, Y.

    2016-10-01

    The recent emergence of hardware architectures characterized by many-core or accelerated processors has opened new opportunities for concurrent programming models taking advantage of both SIMD and SIMT architectures. GeantV, a next generation detector simulation, has been designed to exploit both the vector capability of mainstream CPUs and multi-threading capabilities of coprocessors including NVidia GPUs and Intel Xeon Phi. The characteristics of these architectures are very different in terms of the vectorization depth and type of parallelization needed to achieve optimal performance. In this paper we describe implementation of electromagnetic physics models developed for parallel computing architectures as a part of the GeantV project. Results of preliminary performance evaluation and physics validation are presented as well.

  10. The simulation for the ATLAS experiment Present status and outlook

    CERN Document Server

    Rimoldi, A; Gallas, M; Nairz, A; Boudreau, J; Tsulaia, V; Costanzo, D

    2004-01-01

    The simulation program for the ATLAS experiment is presently operational in a full OO environment. This important physics application has been successfully integrated into ATLAS's common analysis framework, ATHENA. In the last year, following a well stated strategy of transition from a GEANT3 to a GEANT4-based simulation, a careful validation programme confirmed the reliability, performance and robustness of this new tool, as well as its consistency with the results of previous simulation. Generation, simulation and digitization steps on different sets of full physics events we retested for performance. The same software used to simulate the full the ATLAS detector is also used with testbeam configurations. Comparisons to real data in the testbeam validate both the detector description and the physics processes within each subcomponent. In this paper we present the current status of ATLAS GEANT4 simulation, describe the functionality tests performed during its validation phase, and the experience with distrib...

  11. Calorimeter Simulation with Hadrons in CMS

    Energy Technology Data Exchange (ETDEWEB)

    Piperov, Stefan; /Sofiya, Inst. Nucl. Res. /Fermilab

    2008-11-01

    CMS is using Geant4 to simulate the detector setup for the forthcoming data from the LHC. Validation of physics processes inside Geant4 is a major concern in view of getting a proper description of jets and missing energy for signal and background events. This is done by carrying out an extensive studies with test beam using the prototypes or real detector modules of the CMS calorimeter. These data are matched with Geant4 predictions using the same framework that is used for the entire CMS detector. Tuning of the Geant4 models is carried out and steps to be used in reproducing detector signals are defined in view of measurements of energy response, energy resolution, transverse and longitudinal shower profiles for a variety of hadron beams over a broad energy spectrum between 2 to 300 GeV/c. The tuned Monte Carlo predictions match many of these measurements within systematic uncertainties.

  12. The GEANT4 simulation study of the characteristic γ-ray spectrum of TNT under soil induced by DT neutron

    International Nuclear Information System (INIS)

    Qin Xue; Han Jifeng; Yang Chaowen

    2014-01-01

    The characteristic γ-ray spectrum of TNT under soil induced by DT neutron is measured based on the PFTNA demining system. GEANT4 Monte Carlo simulation toolkit is used to simulate the whole experimental procedure. The simulative spectrum is compared with the experimental spectrum. The result shows that they are mainly consistent. It is for the first time to analyze the spectrum by Monte Carlo simulation, the share of the background sources such as neutron, gamma are obtained, the contribution that the experimental apparatus such as shielding, detector sleeve, moderator make to the background is analysed. The study found that the effective gamma signal (from soil and TNT) is only 29% of the full-spectrum signal, and the background signal is more than 68% of the full-spectrum signal, which is mainly produced in the shielding and the detector sleeve. The simulation result shows that by gradually improving the shielding and the cadmium of the detector sleeve, the share of the effective gamma signal can increase to 36% and the background signal can fell 7% eventually. (authors)

  13. Electromagnetic Physics Models for Parallel Computing Architectures

    International Nuclear Information System (INIS)

    Amadio, G; Bianchini, C; Iope, R; Ananya, A; Apostolakis, J; Aurora, A; Bandieramonte, M; Brun, R; Carminati, F; Gheata, A; Gheata, M; Goulas, I; Nikitina, T; Bhattacharyya, A; Mohanty, A; Canal, P; Elvira, D; Jun, S Y; Lima, G; Duhem, L

    2016-01-01

    The recent emergence of hardware architectures characterized by many-core or accelerated processors has opened new opportunities for concurrent programming models taking advantage of both SIMD and SIMT architectures. GeantV, a next generation detector simulation, has been designed to exploit both the vector capability of mainstream CPUs and multi-threading capabilities of coprocessors including NVidia GPUs and Intel Xeon Phi. The characteristics of these architectures are very different in terms of the vectorization depth and type of parallelization needed to achieve optimal performance. In this paper we describe implementation of electromagnetic physics models developed for parallel computing architectures as a part of the GeantV project. Results of preliminary performance evaluation and physics validation are presented as well. (paper)

  14. Monte Carlo simulation of MOSFET dosimeter for electron backscatter using the GEANT4 code.

    Science.gov (United States)

    Chow, James C L; Leung, Michael K K

    2008-06-01

    The aim of this study is to investigate the influence of the body of the metal-oxide-semiconductor field effect transistor (MOSFET) dosimeter in measuring the electron backscatter from lead. The electron backscatter factor (EBF), which is defined as the ratio of dose at the tissue-lead interface to the dose at the same point without the presence of backscatter, was calculated by the Monte Carlo simulation using the GEANT4 code. Electron beams with energies of 4, 6, 9, and 12 MeV were used in the simulation. It was found that in the presence of the MOSFET body, the EBFs were underestimated by about 2%-0.9% for electron beam energies of 4-12 MeV, respectively. The trend of the decrease of EBF with an increase of electron energy can be explained by the small MOSFET dosimeter, mainly made of epoxy and silicon, not only attenuated the electron fluence of the electron beam from upstream, but also the electron backscatter generated by the lead underneath the dosimeter. However, this variation of the EBF underestimation is within the same order of the statistical uncertainties as the Monte Carlo simulations, which ranged from 1.3% to 0.8% for the electron energies of 4-12 MeV, due to the small dosimetric volume. Such small EBF deviation is therefore insignificant when the uncertainty of the Monte Carlo simulation is taken into account. Corresponding measurements were carried out and uncertainties compared to Monte Carlo results were within +/- 2%. Spectra of energy deposited by the backscattered electrons in dosimetric volumes with and without the lead and MOSFET were determined by Monte Carlo simulations. It was found that in both cases, when the MOSFET body is either present or absent in the simulation, deviations of electron energy spectra with and without the lead decrease with an increase of the electron beam energy. Moreover, the softer spectrum of the backscattered electron when lead is present can result in a reduction of the MOSFET response due to stronger

  15. A self-sufficient and general method for self-absorption correction in gamma-ray spectrometry using GEANT4

    International Nuclear Information System (INIS)

    Hurtado, S.; Villa, M.; Manjon, G.; Garcia-Tenorio, R.

    2007-01-01

    This paper presents a self-sufficient and general method for measurement of the activity of low-level gamma-emitters in voluminous samples by gamma-ray spectrometry with a coaxial germanium detector. Due to self-absorption within the sample, the full-energy peak efficiency of low-energy emitters in semiconductor gamma-spectrometers depends strongly on a number of factors including sample composition, density, sample size and gamma-ray energy. As long as those commented factors are well characterized, the influence of self-absorption in the full-energy peak efficiency of low-energy emitters can be calculated using Monte Carlo method based on GEANT4 code for each individual sample. However this task is quite tedious and time consuming. In this paper, we propose an alternative method to determine this influence for voluminous samples of unknown composition. Our method combines both transmission measurements and Monte Carlo simulations, avoiding the application of Monte Carlo full-energy peak efficiency determinations for each individual sample. To test the accuracy and precision of the proposed method, we have calculated 210 Pb activity in sediments samples from an estuary located in the vicinity of several phosphates factories with the proposed method, comparing the obtained results with the ones determined in the same samples using two alternative radiometric techniques

  16. Mucocele fronto-ethmoïdale geante avec extension intracranienne ...

    African Journals Online (AJOL)

    Mucocele fronto-ethmoïdale geante avec extension intracranienne: a propos d'un cas et revue de la litterature. A Kabre, DS Zabsonre, Y Haro. Abstract. Les mucocèles sont des pseudotumeurs kystiques développées aux dépens des sinus paranasaux. D'évolution lente et silencieuse elles se révèlent le plus souvent par ...

  17. A comparison of MCNP6-1.0 and GEANT 4-10.1 when evaluating the neutron output of a complex real world nuclear environment: The thermal neutron facility at the Tri Universities Meson facility

    Energy Technology Data Exchange (ETDEWEB)

    Monk, S.D., E-mail: s.monk@lancaster.ac.uk [Department of Engineering, Lancaster University, Lancaster LA1 4YW (United Kingdom); Shippen, B.A. [Department of Engineering, Lancaster University, Lancaster LA1 4YW (United Kingdom); Colling, B.R. [Department of Engineering, Lancaster University, Lancaster LA1 4YW (United Kingdom); Culham Centre for Fusion Energy, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Cheneler, D.; Al Hamrashdi, H.; Alton, T. [Department of Engineering, Lancaster University, Lancaster LA1 4YW (United Kingdom)

    2017-05-15

    Highlights: • Comparison of the use of MCNP6 and GEANT4 Monte Carlo software when large distances and thicknesses are considered. • The Thermal Neutron Facility (TNF) at TRIUMF used as an example real life example location. • The effects of water, aluminium, iron and lead considered over various thicknesses up to 3 m. - Abstract: A comparison of the Monte Carlo based simulation codes MCNP6-1.0 and GEANT4-10.1 as used for modelling large scale structures is presented here. The high-energy neutron field at the Tri Universities Meson Facility (TRIUMF) in Vancouver, British Columbia is the structure modelled in this work. Work with the emphasis on the modelling of the facility and comparing with experimental results has been published previously, whereas this work is focussed on comparing the performance of the codes over relatively high depths of material rather than the accuracy of the results themselves in comparison to experimental data. Comparisons of three different locations within the neutron facility are modelled and presented using both codes as well as analysis of the transport of typical neutrons fields through large blocks of iron, water, lead and aluminium in order to determine where any deviations are likely to have occurred. Results indicate that over short distances, results from the two codes are in broad agreement – although over greater distances and within more complex geometries, deviation increases dramatically. The conclusions reached are that it is likely the deviations between the codes is caused by both the compounding effect of slight differences between the cross section files used by the two codes to determine the neutron transport through iron, and differences in the processes used by both codes.

  18. 45 CFR 675.4 - Waiver process.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 3 2010-10-01 2010-10-01 false Waiver process. 675.4 Section 675.4 Public Welfare Regulations Relating to Public Welfare (Continued) NATIONAL SCIENCE FOUNDATION MEDICAL CLEARANCE PROCESS FOR DEPLOYMENT TO ANTARCTICA § 675.4 Waiver process. (a) If an individual is found not physically qualified for...

  19. Benchmarking and validation of a Geant4-SHADOW Monte Carlo simulation for dose calculations in microbeam radiation therapy.

    Science.gov (United States)

    Cornelius, Iwan; Guatelli, Susanna; Fournier, Pauline; Crosbie, Jeffrey C; Sanchez Del Rio, Manuel; Bräuer-Krisch, Elke; Rosenfeld, Anatoly; Lerch, Michael

    2014-05-01

    Microbeam radiation therapy (MRT) is a synchrotron-based radiotherapy modality that uses high-intensity beams of spatially fractionated radiation to treat tumours. The rapid evolution of MRT towards clinical trials demands accurate treatment planning systems (TPS), as well as independent tools for the verification of TPS calculated dose distributions in order to ensure patient safety and treatment efficacy. Monte Carlo computer simulation represents the most accurate method of dose calculation in patient geometries and is best suited for the purpose of TPS verification. A Monte Carlo model of the ID17 biomedical beamline at the European Synchrotron Radiation Facility has been developed, including recent modifications, using the Geant4 Monte Carlo toolkit interfaced with the SHADOW X-ray optics and ray-tracing libraries. The code was benchmarked by simulating dose profiles in water-equivalent phantoms subject to irradiation by broad-beam (without spatial fractionation) and microbeam (with spatial fractionation) fields, and comparing against those calculated with a previous model of the beamline developed using the PENELOPE code. Validation against additional experimental dose profiles in water-equivalent phantoms subject to broad-beam irradiation was also performed. Good agreement between codes was observed, with the exception of out-of-field doses and toward the field edge for larger field sizes. Microbeam results showed good agreement between both codes and experimental results within uncertainties. Results of the experimental validation showed agreement for different beamline configurations. The asymmetry in the out-of-field dose profiles due to polarization effects was also investigated, yielding important information for the treatment planning process in MRT. This work represents an important step in the development of a Monte Carlo-based independent verification tool for treatment planning in MRT.

  20. Object-oriented analysis and design of a GEANT based detector simulator

    International Nuclear Information System (INIS)

    Amako, K.; Kanzaki, J.; Sasaki, T.; Takaiwa, Y.; Nakagawa, Y.; Yamagata, T.

    1994-01-01

    The authors give a status report of the project to design a detector simulation program by reengineering GEANT with the object-oriented methodology. They followed the Object Modeling Technique. They explain the object model they constructed. Also problems of the technique found during their study are discussed

  1. Capture reactions at astrophysically relevant energies: extended gas target experiments and GEANT simulations

    CERN Document Server

    Kölle, V; Braitmayer, S E; Mohr, P J; Wilmes, S; Staudt, G; Hammer, J W; Jäger, M; Knee, H; Kunz, R; Mayer, A

    1999-01-01

    Several resonances of the capture reaction sup 2 sup 0 Ne(alpha, gamma) sup 2 sup 4 Mg were measured using an extended windowless gas target system. Detailed GEANT simulations were performed to derive the strength and the total width of the resonances from the measured yield curve. The crucial experimental parameters, which are mainly the density profile in the gas target and the efficiency of the gamma-ray detector, were analyzed by a comparison between the measured data and the corresponding simulation calculations. The excellent agreement between the experimental data and the simulations gives detailed insight into these parameters. (author)

  2. GEANT4 simulation of the neutron background of the C$_6$D$_6$ set-up for capture studies at n_TOF

    CERN Document Server

    Žugec, P.; Bosnar, D.; Altstadt, S.; Andrzejewski, J.; Audouin, L.; Barbagallo, M.; Bécares, V.; Bečvář, F.; Belloni, F.; Berthoumieux, E.; Billowes, J.; Boccone, V.; Brugger, M.; Calviani, M.; Calviño, F.; Cano-Ott, D.; Carrapiço, C.; Cerutti, F.; Chiaveri, E.; Chin, M.; Cortés, G.; Cortés-Giraldo, M.A.; Diakaki, M.; Domingo-Pardo, C.; Dressler, R.; Duran, I.; Dzysiuk, N.; Eleftheriadis, C.; Ferrari, A.; Fraval, K.; Ganesan, S.; García, A.R.; Giubrone, G.; Gómez-Hornillos, M.B.; Gonçalves, I.F.; González-Romero, E.; Griesmayer, E.; Guerrero, C.; Gunsing, F.; Gurusamy, P.; Heinitz, S.; Jenkins, D.G.; Jericha, E.; Kadi, Y.; Käppeler, F.; Karadimos, D.; Kivel, N.; Koehler, P.; Kokkoris, M.; Krtička, M.; Kroll, J.; Langer, C.; Lederer, C.; Leeb, H.; Leong, L.S.; Lo Meo, S.; Losito, R.; Manousos, A.; Marganiec, J.; Martìnez, T.; Massimi, C.; Mastinu, P.F.; Mastromarco, M.; Meaze, M.; Mendoza, E.; Mengoni, A.; Milazzo, P.M.; Mingrone, F.; Mirea, M.; Mondalaers, W.; Paradela, C.; Pavlik, A.; Perkowski, J.; Plompen, A.; Praena, J.; Quesada, J.M.; Rauscher, T.; Reifarth, R.; Riego, A.; Roman, F.; Rubbia, C.; Sarmento, R.; Saxena, A.; Schillebeeckx, P.; Schmidt, S.; Schumann, D.; Tagliente, G.; Tain, J.L.; Tarrío, D.; Tassan-Got, L.; Tsinganis, A.; Valenta, S.; Vannini, G.; Variale, V.; Vaz, P.; Ventura, A.; Versaci, R.; Vermeulen, M.J.; Vlachoudis, V.; Vlastou, R.; Wallner, A.; Ware, T.; Weigand, M.; Weiß, C.; Wright, T.

    2014-05-09

    The neutron sensitivity of the C$_6$D$_6$ detector setup used at n_TOF for capture measurements has been studied by means of detailed GEANT4 simulations. A realistic software replica of the entire n_TOF experimental hall, including the neutron beam line, sample, detector supports and the walls of the experimental area has been implemented in the simulations. The simulations have been analyzed in the same manner as experimental data, in particular by applying the Pulse Height Weighting Technique. The simulations have been validated against a measurement of the neutron background performed with a $^\\mathrm{nat}$C sample, showing an excellent agreement above 1 keV. At lower energies, an additional component in the measured $^\\mathrm{nat}$C yield has been discovered, which prevents the use of $^\\mathrm{nat}$C data for neutron background estimates at neutron energies below a few hundred eV. The origin and time structure of the neutron background have been derived from the simulations. Examples of the neutron backg...

  3. Comparison of SRIM, MCNPX and GEANT simulations with experimental data for thick Al absorbers

    International Nuclear Information System (INIS)

    Evseev, Ivan G.; Schelin, Hugo R.; Paschuk, Sergei A.; Milhoretto, Edney; Setti, Joao A.P.; Yevseyeva, Olga; Assis, Joaquim T. de; Hormaza, Joel M.; Diaz, Katherin S.; Lopes, Ricardo T.

    2010-01-01

    Proton computerized tomography deals with relatively thick targets like the human head or trunk. In this case precise analytical calculation of the proton final energy is a rather complicated task, thus the Monte Carlo simulation stands out as a solution. We used the GEANT4.8.2 code to calculate the proton final energy spectra after passing a thick Al absorber and compared it with the same conditions of the experimental data. The ICRU49, Ziegler85 and Ziegler2000 models from the low energy extension pack were used. The results were also compared with the SRIM2008 and MCNPX2.4 simulations, and with solutions of the Boltzmann transport equation in the Fokker-Planck approximation.

  4. Comparison of SRIM, MCNPX and GEANT simulations with experimental data for thick Al absorbers

    Energy Technology Data Exchange (ETDEWEB)

    Evseev, Ivan G. [Federal University of Technology-Parana-UTFPR, Av.7 de Setembro 3165, Curitiba-PR (Brazil); Schelin, Hugo R. [Federal University of Technology-Parana-UTFPR, Av.7 de Setembro 3165, Curitiba-PR (Brazil)], E-mail: schelin@utfpr.edu.br; Paschuk, Sergei A.; Milhoretto, Edney; Setti, Joao A.P. [Federal University of Technology-Parana-UTFPR, Av.7 de Setembro 3165, Curitiba-PR (Brazil); Yevseyeva, Olga; Assis, Joaquim T. de [Instituto Politecnico da UERJ, Rua Alberto Rangel s/n, Nova Friburgo-RJ (Brazil); Hormaza, Joel M. [Instituto de Biociencias da UNESP, Distrito de Rubiao Junior s/n, Botucatu-SP (Brazil); Diaz, Katherin S. [CEADEN, Calle 30 502 e/5ta y 7ma Avenida, Playa, Ciudad Habana (Cuba); Lopes, Ricardo T. [Laboratorio de Instrumentacao Nuclear, COPPE, UFRJ, Rio de Janeiro-RJ (Brazil)

    2010-04-15

    Proton computerized tomography deals with relatively thick targets like the human head or trunk. In this case precise analytical calculation of the proton final energy is a rather complicated task, thus the Monte Carlo simulation stands out as a solution. We used the GEANT4.8.2 code to calculate the proton final energy spectra after passing a thick Al absorber and compared it with the same conditions of the experimental data. The ICRU49, Ziegler85 and Ziegler2000 models from the low energy extension pack were used. The results were also compared with the SRIM2008 and MCNPX2.4 simulations, and with solutions of the Boltzmann transport equation in the Fokker-Planck approximation.

  5. Performance implications of virtualization and hyper-threading on high energy physics applications in a Grid environment

    CERN Document Server

    Gilbert, Laura; Cobban, M; Iqbal, Saima; Jenwei, Hsieh; Newman, R; Pepper, R; Tseng, Jeffrey

    2005-01-01

    The simulations used in the field of high energy physics are compute intensive and exhibit a high level of data parallelism. These features make such simulations ideal candidates for Grid computing. We are taking as an example the GEANT4 detector simulation used for physics studies within the ATLAS experiment at CERN. One key issue in Grid computing is that of network and system security, which can potentially inhibit the wide spread use of such simulations. Virtualization provides a feasible solution because it allows the creation of virtual compute nodes in both local and remote compute clusters, thus providing an insulating layer which can play an important role in satisfying the security concerns of all parties involved. However, it has performance implications. This study provides quantitative estimates of the virtualization and hyper- threading overhead for GEANT on commodity clusters. Results show that virtualization has less than 15% run-time overhead, and that the best run time (with the non-SMP lice...

  6. Monte Carlo simulations of dose distribution in water phantom for monoenergetic photon sources in the energy range of 20 keV and 2 MeV using a customized GEANT4 distribution

    International Nuclear Information System (INIS)

    Heredia, Eduardo; Rodrigues Jr, Orlando; Campos, Leticia Lucente

    2008-01-01

    Full text: Monte Carlo simulation methods are important tools in the areas of radiation transport and dosimetry, assisting in the radiation therapy treatment planning, study of energy deposition in complex systems and aid in the agreement the experimental results in the research of new materials. However, two aspects can affect the use of these tools: complexity in real world problems transposition to the simulation environment and difficulty in computational codes utilization. The objective of this work is to present a free software distribution based in the GEANT4 Monte Carlo code. The distribution was customized with the addition of tools for the development, visualization and data analysis in a software package with simplified installation and attended configuration. A wizard tool was developed and incorporated to the software package aiming to assist the user in the simulation skeleton creation and the election of the compilation and link flags for new models of simulation in the area of the radiation dosimetry. This software distribution is part of a wider project for the development of an infrastructure based in the GEANT4 for the radiation transport simulation under the perspective of a non centered computational architecture in dosimetry. The absorbed dose distribution in water phantom was simulated for monoenergetic photon sources with energies between 20 keV and 2 MeV. All results and analyses were generated with the tools incorporated in the software package. (author)

  7. Evaluation of the fluence to dose conversion coefficients for high energy neutrons using a voxel phantom coupled with the GEANT4 code

    CERN Document Server

    Paganini, S

    2005-01-01

    Crews working on present-day jet aircraft are a large occupationally exposed group with a relatively high average effective dose from Galactic cosmic radiation. Crews of future high-speed commercial flying at higher altitudes would be even more exposed. To help reduce the significant uncertainties in calculations of such exposures, the male adult voxels phantom MAX, developed in the Nuclear Energy Department of Pernambuco Federal University in Brazil, has been coupled with the Monte Carlo simulation code GEANT4. This toolkit, distributed and upgraded from the international scientific community of CERN/Switzerland, simulates thermal to ultrahigh energy neutrons transport and interactions in the matter. The high energy neutrons are pointed as the component that contribute about 70% of the neutron effective dose that represent the 35% to 60% total dose at aircraft altitude. In this research calculations of conversion coefficients from fluence to effective dose are performed for neutrons of energies from 100 MeV ...

  8. Performance profiling for brachytherapy applications

    Science.gov (United States)

    Choi, Wonqook; Cho, Kihyeon; Yeo, Insung

    2018-05-01

    In many physics applications, a significant amount of software (e.g. R, ROOT and Geant4) is developed on novel computing architectures, and much effort is expended to ensure the software is efficient in terms of central processing unit (CPU) time and memory usage. Profiling tools are used during the evaluation process to evaluate the efficiency; however, few such tools are able to accommodate low-energy physics regions. To address this limitation, we developed a low-energy physics profiling system in Geant4 to profile the CPU time and memory of software applications in brachytherapy applications. This paper describes and evaluates specific models that are applied to brachytherapy applications in Geant4, such as QGSP_BIC_LIV, QGSP_BIC_EMZ, and QGSP_BIC_EMY. The physics range in this tool allows it to be used to generate low energy profiles in brachytherapy applications. This was a limitation in previous studies, which caused us to develop a new profiling tool that supports profiling in the MeV range, in contrast to the TeV range that is supported by existing high-energy profiling tools. In order to easily compare the profiling results between low-energy and high-energy modes, we employed the same software architecture as that in the SimpliCarlo tool developed at the Fermilab National Accelerator Laboratory (FNAL) for the Large Hadron Collider (LHC). The results show that the newly developed profiling system for low-energy physics (less than MeV) complements the current profiling system used for high-energy physics (greater than TeV) applications.

  9. Validation of use of the low energies library in the GATE program: assessment of the effective mass attenuation coefficient

    International Nuclear Information System (INIS)

    Argenta, J.; Brambilla, C.R.; Marques da Silva, A.M.; Hoff, G.

    2009-01-01

    GATE (Geant4 Application for Emission Tomography) is a versatile tool kit for nuclear medicine simulations of SPECT and PET studies. GATE takes advantage of well-validated libraries of physics processes models, geometry description, tracking of particles through materials, response of detector and visualization tools offered by Geant4. One package available to simulate electromagnetic interactions is LEP (Low Energy Electromagnetic Processes). The purpose of this work was to evaluate the LEP package used by GATE 4 for nuclear medicine shielding simulations. Several simulations were made involving a mono directional and 140 keV monoenergetic point source beam, passing through barriers of variable thickness of water and lead. The results showed good agreement with the theoretical model, indicating that GATE 4 uses correctly the LEP package. (author)

  10. Applications Of Monte Carlo Radiation Transport Simulation Techniques For Predicting Single Event Effects In Microelectronics

    International Nuclear Information System (INIS)

    Warren, Kevin; Reed, Robert; Weller, Robert; Mendenhall, Marcus; Sierawski, Brian; Schrimpf, Ronald

    2011-01-01

    MRED (Monte Carlo Radiative Energy Deposition) is Vanderbilt University's Geant4 application for simulating radiation events in semiconductors. Geant4 is comprised of the best available computational physics models for the transport of radiation through matter. In addition to basic radiation transport physics contained in the Geant4 core, MRED has the capability to track energy loss in tetrahedral geometric objects, includes a cross section biasing and track weighting technique for variance reduction, and additional features relevant to semiconductor device applications. The crucial element of predicting Single Event Upset (SEU) parameters using radiation transport software is the creation of a dosimetry model that accurately approximates the net collected charge at transistor contacts as a function of deposited energy. The dosimetry technique described here is the multiple sensitive volume (MSV) model. It is shown to be a reasonable approximation of the charge collection process and its parameters can be calibrated to experimental measurements of SEU cross sections. The MSV model, within the framework of MRED, is examined for heavy ion and high-energy proton SEU measurements of a static random access memory.

  11. Simulation, optimization and testing of a novel high spatial resolution X-ray imager based on Zinc Oxide nanowires in Anodic Aluminium Oxide membrane using Geant4

    Science.gov (United States)

    Esfandi, F.; Saramad, S.

    2015-07-01

    In this work, a new generation of scintillator based X-ray imagers based on ZnO nanowires in Anodized Aluminum Oxide (AAO) nanoporous template is characterized. The optical response of ordered ZnO nanowire arrays in porous AAO template under low energy X-ray illumination is simulated by the Geant4 Monte Carlo code and compared with experimental results. The results show that for 10 keV X-ray photons, by considering the light guiding properties of zinc oxide inside the AAO template and suitable selection of detector thickness and pore diameter, the spatial resolution less than one micrometer and the detector detection efficiency of 66% are accessible. This novel nano scintillator detector can have many advantages for medical applications in the future.

  12. Simulation, optimization and testing of a novel high spatial resolution X-ray imager based on Zinc Oxide nanowires in Anodic Aluminium Oxide membrane using Geant4

    International Nuclear Information System (INIS)

    Esfandi, F.; Saramad, S.

    2015-01-01

    In this work, a new generation of scintillator based X-ray imagers based on ZnO nanowires in Anodized Aluminum Oxide (AAO) nanoporous template is characterized. The optical response of ordered ZnO nanowire arrays in porous AAO template under low energy X-ray illumination is simulated by the Geant4 Monte Carlo code and compared with experimental results. The results show that for 10 keV X-ray photons, by considering the light guiding properties of zinc oxide inside the AAO template and suitable selection of detector thickness and pore diameter, the spatial resolution less than one micrometer and the detector detection efficiency of 66% are accessible. This novel nano scintillator detector can have many advantages for medical applications in the future

  13. Simulating cosmic radiation absorption and secondary particle production of solar panel layers of Low Earth Orbit (LEO) satellite with GEANT4

    Science.gov (United States)

    Yiǧitoǧlu, Merve; Veske, Doǧa; Nilüfer Öztürk, Zeynep; Bilge Demirköz, Melahat

    2016-07-01

    All devices which operate in space are exposed to cosmic rays during their operation. The resulting radiation may cause fatal damages in the solid structure of devices and the amount of absorbed radiation dose and secondary particle production for each component should be calculated carefully before the production. Solar panels are semiconductor solid state devices and are very sensitive to radiation. Even a short term power cut-off may yield a total failure of the satellite. Even little doses of radiation can change the characteristics of solar cells. This deviation can be caused by rarer high energetic particles as well as the total ionizing dose from the abundant low energy particles. In this study, solar panels planned for a specific LEO satellite, IMECE, are analyzed layer by layer. The Space Environment Information System (SPENVIS) database and GEANT4 simulation software are used to simulate the layers of the panels. The results obtained from the simulation will be taken in account to determine the amount of radiation protection and resistance needed for the panels or to revise the design of the panels.

  14. The GEANT4 toolkit capability in the hadron therapy field: simulation of a transport beam line

    International Nuclear Information System (INIS)

    Cirrone, G.A.P.; Cuttone, G.; Di Rosa, F.; Raffaele, L.; Russo, G.; Guatelli, S.; Pia, M.G.

    2006-01-01

    At Laboratori Nazionali del Sud of the Instituto Nazionale di Fisica Nucleare of Catania (Sicily, Italy), the first Italian hadron therapy facility named CATANA (Centro di AdroTerapia ed Applicazioni Nucleari Avanzate) has been realized. Inside CATANA 62 MeV proton beams, accelerated by a superconducting cyclotron, are used for the radiotherapeutic treatments of some types of ocular tumours. Therapy with hadron beams still represents a pioneer technique, and only a few centers worldwide can provide this advanced specialized cancer treatment. On the basis of the experience so far gained, and considering the future hadron-therapy facilities to be developed (Rinecker, Munich Germany, Heidelberg/GSI, Darmstadt, Germany, PSI Villigen, Switzerland, CNAO, Pavia, Italy, Centro di Adroterapia, Catania, Italy) we decided to develop a Monte Carlo application based on the GEANT4 toolkit, for the design, the realization and the optimization of a proton-therapy beam line. Another feature of our project is to provide a general tool able to study the interactions of hadrons with the human tissue and to test the analytical-based treatment planning systems actually used in the routine practice. All the typical elements of a hadron-therapy line, such as diffusers, range shifters, collimators and detectors were modelled. In particular, we simulated the Markus type ionization chamber and a Gaf Chromic film as dosimeters to reconstruct the depth (Bragg peak and Spread Out Bragg Peak) and lateral dose distributions, respectively. We validated our simulated detectors comparing the results with the experimental data available in our facility

  15. The GEANT4 toolkit capability in the hadron therapy field: simulation of a transport beam line

    Science.gov (United States)

    Cirrone, G. A. P.; Cuttone, G.; Di Rosa, F.; Raffaele, L.; Russo, G.; Guatelli, S.; Pia, M. G.

    2006-01-01

    At Laboratori Nazionali del Sud of the Instituto Nazionale di Fisica Nucleare of Catania (Sicily, Italy), the first Italian hadron therapy facility named CATANA (Centro di AdroTerapia ed Applicazioni Nucleari Avanzate) has been realized. Inside CATANA 62 MeV proton beams, accelerated by a superconducting cyclotron, are used for the radiotherapeutic treatments of some types of ocular tumours. Therapy with hadron beams still represents a pioneer technique, and only a few centers worldwide can provide this advanced specialized cancer treatment. On the basis of the experience so far gained, and considering the future hadron-therapy facilities to be developed (Rinecker, Munich Germany, Heidelberg/GSI, Darmstadt, Germany, PSI Villigen, Switzerland, CNAO, Pavia, Italy, Centro di Adroterapia, Catania, Italy) we decided to develop a Monte Carlo application based on the GEANT4 toolkit, for the design, the realization and the optimization of a proton-therapy beam line. Another feature of our project is to provide a general tool able to study the interactions of hadrons with the human tissue and to test the analytical-based treatment planning systems actually used in the routine practice. All the typical elements of a hadron-therapy line, such as diffusers, range shifters, collimators and detectors were modelled. In particular, we simulated the Markus type ionization chamber and a Gaf Chromic film as dosimeters to reconstruct the depth (Bragg peak and Spread Out Bragg Peak) and lateral dose distributions, respectively. We validated our simulated detectors comparing the results with the experimental data available in our facility.

  16. The GEANT4 toolkit capability in the hadron therapy field: simulation of a transport beam line

    Energy Technology Data Exchange (ETDEWEB)

    Cirrone, G.A.P. [Laboratori Nazionali del Sud, Istituto Nazionale di Fisica Nucleare, Via S. Sofia 62, Catania (Italy); Cuttone, G. [Laboratori Nazionali del Sud, Istituto Nazionale di Fisica Nucleare, Via S. Sofia 62, Catania (Italy); Di Rosa, F. [Laboratori Nazionali del Sud, Istituto Nazionale di Fisica Nucleare, Via S. Sofia 62, Catania (Italy); Raffaele, L. [Laboratori Nazionali del Sud, Istituto Nazionale di Fisica Nucleare, Via S. Sofia 62, Catania (Italy); Russo, G. [Laboratori Nazionali del Sud, Istituto Nazionale di Fisica Nucleare, Via S. Sofia 62, Catania (Italy); Guatelli, S. [Istituto Nazionale di Fisica Nucleare, Sezione di Genova, Via Dodecaneso 33, Genova (Italy); Pia, M.G. [Istituto Nazionale di Fisica Nucleare, Sezione di Genova, Via Dodecaneso 33, Genova (Italy)

    2006-01-15

    At Laboratori Nazionali del Sud of the Instituto Nazionale di Fisica Nucleare of Catania (Sicily, Italy), the first Italian hadron therapy facility named CATANA (Centro di AdroTerapia ed Applicazioni Nucleari Avanzate) has been realized. Inside CATANA 62 MeV proton beams, accelerated by a superconducting cyclotron, are used for the radiotherapeutic treatments of some types of ocular tumours. Therapy with hadron beams still represents a pioneer technique, and only a few centers worldwide can provide this advanced specialized cancer treatment. On the basis of the experience so far gained, and considering the future hadron-therapy facilities to be developed (Rinecker, Munich Germany, Heidelberg/GSI, Darmstadt, Germany, PSI Villigen, Switzerland, CNAO, Pavia, Italy, Centro di Adroterapia, Catania, Italy) we decided to develop a Monte Carlo application based on the GEANT4 toolkit, for the design, the realization and the optimization of a proton-therapy beam line. Another feature of our project is to provide a general tool able to study the interactions of hadrons with the human tissue and to test the analytical-based treatment planning systems actually used in the routine practice. All the typical elements of a hadron-therapy line, such as diffusers, range shifters, collimators and detectors were modelled. In particular, we simulated the Markus type ionization chamber and a Gaf Chromic film as dosimeters to reconstruct the depth (Bragg peak and Spread Out Bragg Peak) and lateral dose distributions, respectively. We validated our simulated detectors comparing the results with the experimental data available in our facility.

  17. Validation of use of the low energies library in the GATE program: assessment of the effective mass attenuation coefficient

    International Nuclear Information System (INIS)

    Argenta, Jackson; Brambilla, Claudia R.; Silva, Ana Maria Marques da; Hoff, Gabriela

    2010-01-01

    Geant4 Application for Emission Tomography program (GATE) is a versatile toolkit for nuclear medicine simulations of SPECT and PET studies. GATE takes advantage of well-validated libraries of physics processes models, geometry description, tracking of particles through materials, response of detector and visualization tools offered by Geant4 (version 4.0). One package available to simulate electromagnetic interactions is low energy electromagnetic processes (LEP). The purpose of this work was to evaluate the LEP package used by GATE 4 for nuclear medicine shielding simulations. Several simulations were made involving a monodirectional and 140 keV monoenergetic point source beam, passing through barriers of variable thickness of water and lead. The results showed good agreement with the theoretical model, indicating that GATE 4 uses correctly the LEP package. (author)

  18. Number distribution of leakage neutrons for single neutron emission event and one source emission event in multiplying medium for two variables - a GEANT4 study

    International Nuclear Information System (INIS)

    Roy, Arup Singha; Raman, Anand; Chaudhury, Probal; Thomas, Renju G.

    2018-01-01

    A quantitative knowledge about the neutron multiplying character of a neutron multiplying medium such as High enriched Uranium (HEU), Weapon Graded plutonium (WGPu) and similar special nuclear materials is essential for improving the probability of detection of these materials to check against illicit trafficking. The objective of this study is to gain a deeper insight in to the neutron and gamma multiplication behaviour of these materials. The leakage number distribution of neutron and gamma initiated by a source emission event (Spontaneous Fission) as well as single neutron emission event has been obtained in the course of this study. The computations for this study were carried out through GEANT4 simulation and also with the help of FREYA incorporated into it. This helped to carry out a detailed analysis of each history more realistically and obtain more reliable results

  19. Simulation calculations using the code Geant III for the EUROGAM device

    Energy Technology Data Exchange (ETDEWEB)

    Beck, F A; Curien, D; Duchene, G; France, G de; Wei, L [Strasbourg-1 Univ., 67 (France). Centre de Recherches Nucleaires

    1992-08-01

    Simulation calculations are good tools to determine, at a low cost, the characteristics of a detector. It enables to change the geometry of the counter in an iterative way to optimize its response leading to the best performances for the whole multi-detector device. This kind of calculations have been performed using the Geant III code for the EUROGAM device. (author). 3 tabs., 5 figs.

  20. Algorithms and parameters for improved accuracy in physics data libraries

    International Nuclear Information System (INIS)

    Batič, M; Hoff, G; Pia, M G; Saracco, P; Han, M; Kim, C H; Hauf, S; Kuster, M; Seo, H

    2012-01-01

    Recent efforts for the improvement of the accuracy of physics data libraries used in particle transport are summarized. Results are reported about a large scale validation analysis of atomic parameters used by major Monte Carlo systems (Geant4, EGS, MCNP, Penelope etc.); their contribution to the accuracy of simulation observables is documented. The results of this study motivated the development of a new atomic data management software package, which optimizes the provision of state-of-the-art atomic parameters to physics models. The effect of atomic parameters on the simulation of radioactive decay is illustrated. Ideas and methods to deal with physics models applicable to different energy ranges in the production of data libraries, rather than at runtime, are discussed.

  1. Use of the GEANT4 Monte Carlo to determine three-dimensional dose factors for radionuclide dosimetry

    International Nuclear Information System (INIS)

    Amato, Ernesto; Italiano, Antonio; Minutoli, Fabio; Baldari, Sergio

    2013-01-01

    The voxel-level dosimetry is the most simple and common approach to internal dosimetry of nonuniform distributions of activity within the human body. Aim of this work was to obtain the dose “S” factors (mGy/MBqs) at the voxel level for eight beta and beta–gamma emitting radionuclides commonly used in nuclear medicine diagnostic and therapeutic procedures. We developed a Monte Carlo simulation in GEANT4 of a region of soft tissue as defined by the ICRP, divided into 11×11×11 cubic voxels, 3 mm in side. The simulation used the parameterizations of the electromagnetic interaction optimized for low energy (EEDL, EPDL). The decay of each radionuclide ( 32 P, 90 Y, 99m Tc, 177 Lu, 131 I, 153 Sm, 186 Re, 188 Re) were simulated homogeneously distributed within the central voxel (0,0,0), and the energy deposited in the surrounding voxels was mediated on the 8 octants of the three dimensional space, for reasons of symmetry. The results obtained were compared with those available in the literature. While the iodine deviations remain within 16%, for phosphorus, a pure beta emitter, the agreement is very good for self-dose (0,0,0) and good for the dose to first neighbors, while differences are observed ranging from −60% to +100% for voxels far distant from the source. The existence of significant differences in the percentage calculation of the voxel S factors, especially for pure beta emitters such as 32 P or 90 Y, has already been highlighted by other authors. These data can usefully extend the dosimetric approach based on the voxel to other radionuclides not covered in the available literature

  2. Contribution to the energy calibration of GLAST-LAT's calorimeter and validation of hadronic cascade models available with GEANT4

    International Nuclear Information System (INIS)

    Bregeon, J.

    2005-09-01

    GLAST is the new generation of Gamma-ray telescope and should dramatically improve our knowledge of the gamma-ray sky when it is launched on September 7. 2007. Data from the beam test that was held at GANIL with low energy ions were analyzed in order to measure the light quenching factor of CsI for all kinds of ions from proton to krypton of energy between 0 and 73 MeV per nucleon. These results have been very useful to understand the light quenching for relativistic ions that was measured during the GSI beam test. The knowledge of light quenching in GLAST CsI detectors for high energy ions is required for the on-orbit calibration with cosmic rays to succeed. Hadronic background rejection is another major issue for GLAST, thus, all the algorithms rely on the GLAST official Monte-Carlo simulation, GlastRelease. Hadronic cascade data from the GSI beam test and from another beam test held at CERN on the SPS have been used to benchmark hadronic cascade simulation within the framework of GEANT4, on which GlastRelease is based. Testing the good reproduction of simple parameters in GLAST-like calorimeters for hadronic cascades generated by 1.7 GeV, 3.4 GeV, 10 GeV and 20 GeV protons or pions led us to the conclusion that at high energy the default LHEP model is good enough, whereas at low energy the Bertini intra-nuclear cascade model should be used. (author)

  3. gemcWeb: A Cloud Based Nuclear Physics Simulation Software

    Science.gov (United States)

    Markelon, Sam

    2017-09-01

    gemcWeb allows users to run nuclear physics simulations from the web. Being completely device agnostic, scientists can run simulations from anywhere with an Internet connection. Having a full user system, gemcWeb allows users to revisit and revise their projects, and share configurations and results with collaborators. gemcWeb is based on simulation software gemc, which is based on standard GEant4. gemcWeb requires no C++, gemc, or GEant4 knowledge. Using a simple but powerful GUI allows users to configure their project from geometries and configurations stored on the deployment server. Simulations are then run on the server, with results being posted to the user, and then securely stored. Python based and open-source, the main version of gemcWeb is hosted internally at Jefferson National Labratory and used by the CLAS12 and Electron-Ion Collider Project groups. However, as the software is open-source, and hosted as a GitHub repository, an instance can be deployed on the open web, or any institution's intra-net. An instance can be configured to host experiments specific to an institution, and the code base can be modified by any individual or group. Special thanks to: Maurizio Ungaro, PhD., creator of gemc; Markus Diefenthaler, PhD., advisor; and Kyungseon Joo, PhD., advisor.

  4. Efficiency corrections in determining the (137)Cs inventory of environmental soil samples by using relative measurement method and GEANT4 simulations.

    Science.gov (United States)

    Li, Gang; Liang, Yongfei; Xu, Jiayun; Bai, Lixin

    2015-08-01

    The determination of (137)Cs inventory is widely used to estimate the soil erosion or deposition rate. The generally used method to determine the activity of volumetric samples is the relative measurement method, which employs a calibration standard sample with accurately known activity. This method has great advantages in accuracy and operation only when there is a small difference in elemental composition, sample density and geometry between measuring samples and the calibration standard. Otherwise it needs additional efficiency corrections in the calculating process. The Monte Carlo simulations can handle these correction problems easily with lower financial cost and higher accuracy. This work presents a detailed description to the simulation and calibration procedure for a conventionally used commercial P-type coaxial HPGe detector with cylindrical sample geometry. The effects of sample elemental composition, density and geometry were discussed in detail and calculated in terms of efficiency correction factors. The effect of sample placement was also analyzed, the results indicate that the radioactive nuclides and sample density are not absolutely uniform distributed along the axial direction. At last, a unified binary quadratic functional relationship of efficiency correction factors as a function of sample density and height was obtained by the least square fitting method. This function covers the sample density and height range of 0.8-1.8 g/cm(3) and 3.0-7.25 cm, respectively. The efficiency correction factors calculated by the fitted function are in good agreement with those obtained by the GEANT4 simulations with the determination coefficient value greater than 0.9999. The results obtained in this paper make the above-mentioned relative measurements more accurate and efficient in the routine radioactive analysis of environmental cylindrical soil samples. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Use of the GEANT4 Monte Carlo to determine three-dimensional dose factors for radionuclide dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Amato, Ernesto, E-mail: eamato@unime.it [University of Messina, Department of Biomedical Sciences and of Morphologic and Functional Imaging, Section of Radiological Sciences (Italy); Italiano, Antonio [INFN – Istituto Nazionale di Fisica Nucleare, Gruppo Collegato di Messina (Italy); Minutoli, Fabio; Baldari, Sergio [University of Messina, Department of Biomedical Sciences and of Morphologic and Functional Imaging, Section of Radiological Sciences (Italy)

    2013-04-21

    The voxel-level dosimetry is the most simple and common approach to internal dosimetry of nonuniform distributions of activity within the human body. Aim of this work was to obtain the dose “S” factors (mGy/MBqs) at the voxel level for eight beta and beta–gamma emitting radionuclides commonly used in nuclear medicine diagnostic and therapeutic procedures. We developed a Monte Carlo simulation in GEANT4 of a region of soft tissue as defined by the ICRP, divided into 11×11×11 cubic voxels, 3 mm in side. The simulation used the parameterizations of the electromagnetic interaction optimized for low energy (EEDL, EPDL). The decay of each radionuclide ({sup 32}P, {sup 90}Y, {sup 99m}Tc, {sup 177}Lu, {sup 131}I, {sup 153}Sm, {sup 186}Re, {sup 188}Re) were simulated homogeneously distributed within the central voxel (0,0,0), and the energy deposited in the surrounding voxels was mediated on the 8 octants of the three dimensional space, for reasons of symmetry. The results obtained were compared with those available in the literature. While the iodine deviations remain within 16%, for phosphorus, a pure beta emitter, the agreement is very good for self-dose (0,0,0) and good for the dose to first neighbors, while differences are observed ranging from −60% to +100% for voxels far distant from the source. The existence of significant differences in the percentage calculation of the voxel S factors, especially for pure beta emitters such as {sup 32}P or {sup 90}Y, has already been highlighted by other authors. These data can usefully extend the dosimetric approach based on the voxel to other radionuclides not covered in the available literature.

  6. Progress Report [2. Research Coordination Meeting on Heavy Charged-Particle Interaction Data for Radiotherapy

    International Nuclear Information System (INIS)

    Quesada, J.M.

    2010-01-01

    Full text: Geant4 is a general purpose toolkit for the simulation of the passage of particles through matter. Primary focus of Geant4 was on preparation of experiments for CERN Large Hadron Collider. Other areas of application are growing and include high energy, nuclear and accelerator physics, studies in hadronic therapy, tomography, space dosimetry, and others. Geant4 physics includes different models for simulation of interactions of hadrons with nuclei. For the simulation of reactions of interest in hadrontherapy, the Bertini-style cascade (BERT) and the binary cascade (BIC) models are available. Both of them include, as final stages after the kinetic cascade regime, sequential pre-equilibrium and de-excitation phases. Nevertheless, the high degree of accuracy required for practical applications needed for an overall improvement of the performance of the Geant4 hadronic models. In particular, our work has been concentrated in the pre-equilibrium and de-excitation models included in the binary cascade physics list. New physics has been included mainly through the implementation of more realistic inverse reaction cross sections for nucleons and light charged particles. An intensive bug-fixing effort has been made, which very much improved the description of charged particle emissions and fission. These achievements favoured the participation of Geant4 into the IAEA benchmark of spallation models. Low energy region of the benchmark (below 200 MeV) and some materials of interest are common to hadrontherapy (structural materials for shielding, collimators, etc.), which justifies its inclusion in the present brief report. For neutrons below 20 MeV, Geant4 High Precision parameterized model is recommended, although there is no direct access in Geant-4 to evaluated data in ENDF format; it uses some specific libraries which contain, in principle, the same type of information as the ENDF-6 format files, but they do not cover all presently evaluated nuclei and reactions

  7. Variation of Bragg curve characteristic induced by changing the position of inhomogeneous material: Geant4 simulation study

    Energy Technology Data Exchange (ETDEWEB)

    Park, So-Hyun; Jung, Won-Gyun; Suh, Tae-Suk [Catholic University, Seoul (Korea, Republic of); Jang, Hong-Seok; Choi, Byeong-Oak [Seoul St. Mary' s Hospital, Seoul (Korea, Republic of); Rah, Jeong-Eun; Park, Sun-Gyong; Lee, Se-Byeong [National Cancer Center, Ilsan (Korea, Republic of)

    2011-02-15

    When proton beam passes through the human body, the stopping power and the depth-dose distribution of the proton are influenced by the relative location among adjacent materials or the difference in material conditions. Our study demonstrates the effect of inhomogeneous materials placed in the Plateau and Bragg peak regions of the Bragg curve in water. We evaluated the Bragg peak position, range, penumbra and integrated doses by using the Geant4 simulation toolkit. The positions of inhomogeneities were selected as the proximal 36% and 50% points of the maximum dose, which indicates the location at entrance regions of the Plateau and the Bragg peak, respectively. Bone (density {rho} = 1.85 g/cm{sup 3}) and adipose tissue (density {rho} = 0.92 g/cm{sup 3}) were selected as inhomogeneous materials. The thickness of each material was varied by 0.1 cm between 0.1 cm and 1.0 cm. In addition, the initial energy of the proton beam was changed in 30 MeV steps between 108 MeV and 220 MeV. The effects of inhomogeneous conditions were performed for various parameters: Bragg peak position, range, penumbra width, full width at half maximum and dose of Bragg curve. A dose perturbation was observed in the region of the Bragg peak and inhomogeneous material, especially, When the bone equivalent material was inserted within the Bragg curve. However, there were no significant variations in the other parameters, except for the dose perturbation depending on the inserted location of each material. This study shows the characteristic changes in the Bragg curve due to inhomogeneous materials.

  8. Design and Construction of a Positron Emission Tomography (PET) Unit and Medical Applications with GEANT Detector Simulation Package

    Energy Technology Data Exchange (ETDEWEB)

    Karagoz, Muge [Bogazici Univ., Istanbul (Turkey)

    1998-01-01

    In order to investigate the possibility of the construction of a sample PET coincidence unit in our HEP laboratory, a setup with two face to face PMTs and two 2x8 Csi(Tl) scintillator matrices has been constructed. In this setup, 1-D projections of a pointlike 22 Na positron source at different angles have been measured. Using these projections a 2-D image has been formed. Monte Carlo studies of this setup have been implemented using the detector simulation tool in CERN program library, GEANT. Again with GEANT a sample human body is created to study the effects of proton therapy. Utilization of the simulation as a pretherapy tool is also investigated.

  9. Validation of GEANT3 simulation studies with a dual-head PMT ClearPET TM prototype

    CERN Document Server

    Ziemons, K; Streun, M; Pietrzyk, U

    2004-01-01

    The ClearPET TM project is proposed by working groups of the Crystal Clear Collaboration (CCC) to develop a 2/sup nd/ generation high performance small animal positron emission tomograph (PET). High sensitivity and high spatial resolution is foreseen for the ClearPET TM camera by using a phoswich arrangement combining mixed lutetium yttrium aluminum perovskite (LuYAP:Ce) and lutetium oxyorthosilicate (LSO) scintillating crystals. Design optimizations for the first photomultiplier tube (PMT) based ClearPET camera are done with a Monte-Carlo simulation package implemented on GEANT3 (CERN, Geneva, Switzerland). A dual-head prototype has been built to test the frontend electronics and was used to validate the implementation of the GEANT3 simulation tool. Multiple simulations were performed following the experimental protocols to measure the intrinsic resolution and the sensitivity profile in axial and radial direction. Including a mean energy resolution of about 27.0% the simulated intrinsic resolution is about (...

  10. Beam Delivery Simulation: BDSIM - Development & Optimization

    CERN Document Server

    Nevay, Laurence James; Garcia-Morales, H; Gibson, S M; Kwee-Hinzmann, R; Snuverink, J; Deacon, L C

    2014-01-01

    Beam Delivery Simulation (BDSIM) is a Geant4 and C++ based particle tracking code that seamlessly tracks particles through accelerators and detectors, including the full range of particle interaction physics processes from Geant4. BDSIM has been successfully used to model beam loss and background conditions for many current and future linear accelerators such as the Accelerator Test Facility 2 (ATF2) and the International Linear Collider (ILC). Current developments extend its application for use with storage rings, in particular for the Large Hadron Collider (LHC) and the High Luminosity upgrade project (HL-LHC). This paper presents the latest results from using BDSIM to model the LHC as well as the developments underway to improve performance.

  11. Monte Carlo simulation of the ELIMED beamline using Geant4

    Czech Academy of Sciences Publication Activity Database

    Pipek, J.; Romano, F.; Milluzzo, G.; Cirrone, G.A.P.; Cuttone, G.; Amico, A.G.; Margarone, Daniele; Larosa, G.; Leanza, R.; Petringa, G.; Schillaci, Francesco; Scuderi, Valentina

    2017-01-01

    Roč. 12, Mar (2017), s. 1-5, č. článku C03027. ISSN 1748-0221 R&D Projects: GA MŠk EF15_008/0000162; GA MŠk LQ1606 Grant - others:ELI Beamlines(XE) CZ.02.1.01/0.0/0.0/15_008/0000162 Institutional support: RVO:68378271 Keywords : models and simulation s * accelerator applications * beam dynamics * software architectures * event data models * frameworks and databases Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: Fluids and plasma physics (including surface physics) Impact factor: 1.220, year: 2016

  12. 4th ATLAS Physics Workshop (Athens) - Report from the Physics Sessions

    CERN Multimedia

    Kersevan, B P

    The 4th ATLAS Physics Workshop provided a showcase for studies of some of the most exciting aspects of LHC physics, both within the Standard Model and beyond. It was clear from the wide range of topics covered, from QCD studies to TeV-scale Black Hole production, that preparations are well in hand for understanding whatever Nature, and the LHC, may throw at us. The Standard Model session concentrated on QCD and Electroweak physics, which will form the core of the ATLAS physics program during the first years of LHC operation. Convenor Matt Dobbs began by summarising recent and ongoing studies and pointed out that the first ATLAS papers will aim to prove that we understand LHC physics in the regime where the Standard Model is reliable. Only then will we be able to make convincing claims for the existence of New Physics. Subsequent talks discussed our understanding of this 'bread-and-butter' physics, including minimum bias processes and underlying events (Arthur Moraes), Parton Distribution Functions (Jon Butte...

  13. Evaluation of static physics performance of the jPET-D4 by Monte Carlo simulations

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, Tomoyuki [Allied Health Sciences, Kitasato University, Kitasato 1-15-1, Sagamihara, Kanagawa, 228-8555 (Japan); Yoshida, Eiji [Molecular Imaging Centre, National Institute of Radiological Sciences, Anagawa 4-9-1, Inage, Chiba, 263-8555 (Japan); Kobayashi, Ayako [Graduate School of Human Health Sciences, Tokyo Metropolitan University, Arakawa, Tokyo, 116-8551 (Japan); Shibuya, Kengo [Molecular Imaging Centre, National Institute of Radiological Sciences, Anagawa 4-9-1, Inage, Chiba, 263-8555 (Japan); Nishikido, Fumihiko [Molecular Imaging Centre, National Institute of Radiological Sciences, Anagawa 4-9-1, Inage, Chiba, 263-8555 (Japan); Kobayashi, Tetsuya [Graduate School of Science and Technology, Chiba University, 1-33 Yayoi, Inage, Chiba, 263-8522 (Japan); Suga, Mikio [Graduate School of Science and Technology, Chiba University, 1-33 Yayoi, Inage, Chiba, 263-8522 (Japan); Yamaya, Taiga [Molecular Imaging Centre, National Institute of Radiological Sciences, Anagawa 4-9-1, Inage, Chiba, 263-8555 (Japan); Kitamura, Keishi [Shimadzu Corporation, 1 Nishinokyo-kuwabara-cho, Nakagyo-ku, Kyoto, 604-8511 (Japan); Maruyama, Koichi [Allied Health Sciences, Kitasato University, Kitasato 1-15-1, Sagamihara, Kanagawa, 228-8555 (Japan); Murayama, Hideo [Molecular Imaging Centre, National Institute of Radiological Sciences, Anagawa 4-9-1, Inage, Chiba, 263-8555 (Japan)

    2007-01-07

    The jPET-D4 is the first PET scanner to introduce a unique four-layer depth-of-interaction (DOI) detector scheme in order to achieve high sensitivity and uniform high spatial resolution. This paper compares measurement and Monte Carlo simulation results of the static physics performance of this prototype research PET scanner. Measurement results include single and coincidence energy spectra, point and line source sensitivities, axial sensitivity profile (slice profile) and scatter fraction. We use GATE (Geant4 application for tomographic emission) as a Monte Carlo radiation transport model. Experimental results are reproduced well by the simulation model with reasonable assumptions on characteristic responses of the DOI detectors. In a previous study, the jPET-D4 was shown to provide a uniform spatial resolution as good as 3 mm (FHWM). In the present study, we demonstrate that a high sensitivity, 11.3 {+-} 0.5%, is provided at the FOV centre. However, about three-fourths of this sensitivity is related to multiple-crystal events, for which some misidentification of the crystal cannot be avoided. Therefore, it is crucial to develop a more efficient way to identify the crystal of interaction and to reduce misidentification in order to make use of these high performance values simultaneously. We expect that effective sensitivity can be improved by replacing the GSO crystals with more absorptive crystals such as BGO and LSO. The results we describe here are essential to take full advantage of the next generation PET systems that have DOI recognition capability.

  14. GEANT4 simulation of a scintillating-fibre tracker for the cosmic-ray muon tomography of legacy nuclear waste containers

    Energy Technology Data Exchange (ETDEWEB)

    Clarkson, A.; Hamilton, D.J.; Hoek, M.; Ireland, D.G. [SUPA, School of Physics and Astronomy, University of Glasgow, Kelvin Building, University Avenue, Glasgow G12 8QQ, Scotland (United Kingdom); Johnstone, J.R. [National Nuclear Laboratory, Central Laboratory, Sellafield, Seascale, Cumbria CA20 1PG, England (United Kingdom); Kaiser, R.; Keri, T.; Lumsden, S. [SUPA, School of Physics and Astronomy, University of Glasgow, Kelvin Building, University Avenue, Glasgow G12 8QQ, Scotland (United Kingdom); Mahon, D.F., E-mail: David.Mahon@Glasgow.ac.uk [SUPA, School of Physics and Astronomy, University of Glasgow, Kelvin Building, University Avenue, Glasgow G12 8QQ, Scotland (United Kingdom); McKinnon, B.; Murray, M.; Nutbeam-Tuffs, S. [SUPA, School of Physics and Astronomy, University of Glasgow, Kelvin Building, University Avenue, Glasgow G12 8QQ, Scotland (United Kingdom); Shearer, C.; Staines, C. [National Nuclear Laboratory, Central Laboratory, Sellafield, Seascale, Cumbria CA20 1PG, England (United Kingdom); Yang, G. [SUPA, School of Physics and Astronomy, University of Glasgow, Kelvin Building, University Avenue, Glasgow G12 8QQ, Scotland (United Kingdom); Zimmerman, C. [National Nuclear Laboratory, Central Laboratory, Sellafield, Seascale, Cumbria CA20 1PG, England (United Kingdom)

    2014-05-11

    Cosmic-ray muons are highly penetrative charged particles that are observed at the sea level with a flux of approximately one per square centimetre per minute. They interact with matter primarily through Coulomb scattering, which is exploited in the field of muon tomography to image shielded objects in a wide range of applications. In this paper, simulation studies are presented that assess the feasibility of a scintillating-fibre tracker system for use in the identification and characterisation of nuclear materials stored within industrial legacy waste containers. A system consisting of a pair of tracking modules above and a pair below the volume to be assayed is simulated within the GEANT4 framework using a range of potential fibre pitches and module separations. Each module comprises two orthogonal planes of fibres that allow the reconstruction of the initial and Coulomb-scattered muon trajectories. A likelihood-based image reconstruction algorithm has been developed that allows the container content to be determined with respect to the scattering density λ, a parameter which is related to the atomic number Z of the scattering material. Images reconstructed from this simulation are presented for a range of anticipated scenarios that highlight the expected image resolution and the potential of this system for the identification of high-Z materials within a shielded, concrete-filled container. First results from a constructed prototype system are presented in comparison with those from a detailed simulation. Excellent agreement between experimental data and simulation is observed showing clear discrimination between the different materials assayed throughout.

  15. GEANT4 simulation of a scintillating-fibre tracker for the cosmic-ray muon tomography of legacy nuclear waste containers

    Science.gov (United States)

    Clarkson, A.; Hamilton, D. J.; Hoek, M.; Ireland, D. G.; Johnstone, J. R.; Kaiser, R.; Keri, T.; Lumsden, S.; Mahon, D. F.; McKinnon, B.; Murray, M.; Nutbeam-Tuffs, S.; Shearer, C.; Staines, C.; Yang, G.; Zimmerman, C.

    2014-05-01

    Cosmic-ray muons are highly penetrative charged particles that are observed at the sea level with a flux of approximately one per square centimetre per minute. They interact with matter primarily through Coulomb scattering, which is exploited in the field of muon tomography to image shielded objects in a wide range of applications. In this paper, simulation studies are presented that assess the feasibility of a scintillating-fibre tracker system for use in the identification and characterisation of nuclear materials stored within industrial legacy waste containers. A system consisting of a pair of tracking modules above and a pair below the volume to be assayed is simulated within the GEANT4 framework using a range of potential fibre pitches and module separations. Each module comprises two orthogonal planes of fibres that allow the reconstruction of the initial and Coulomb-scattered muon trajectories. A likelihood-based image reconstruction algorithm has been developed that allows the container content to be determined with respect to the scattering density λ, a parameter which is related to the atomic number Z of the scattering material. Images reconstructed from this simulation are presented for a range of anticipated scenarios that highlight the expected image resolution and the potential of this system for the identification of high-Z materials within a shielded, concrete-filled container. First results from a constructed prototype system are presented in comparison with those from a detailed simulation. Excellent agreement between experimental data and simulation is observed showing clear discrimination between the different materials assayed throughout.

  16. First experience of vectorizing electromagnetic physics models for detector simulation

    International Nuclear Information System (INIS)

    Amadio, G; Bianchini, C; Apostolakis, J; Bitzes, G; Brun, R; Carminati, F; Gheata, A; Novak, M; Shadura, O; Wenzel, S; Bandieramonte, M; Canal, P; Elvira, D; Jun, S Y; Lima, G; Licht, J de Fine; Duhem, L; Presbyterian, M; Seghal, R

    2015-01-01

    The recent emergence of hardware architectures characterized by many-core or accelerated processors has opened new opportunities for concurrent programming models taking advantage of both SIMD and SIMT architectures. The GeantV vector prototype for detector simulations has been designed to exploit both the vector capability of mainstream CPUs and multi-threading capabilities of coprocessors including NVidia GPUs and Intel Xeon Phi. The characteristics of these architectures are very different in terms of the vectorization depth, parallelization needed to achieve optimal performance or memory access latency and speed. An additional challenge is to avoid the code duplication often inherent to supporting heterogeneous platforms. In this paper we present the first experience of vectorizing electromagnetic physics models developed for the GeantV project. (paper)

  17. First experience of vectorizing electromagnetic physics models for detector simulation

    Science.gov (United States)

    Amadio, G.; Apostolakis, J.; Bandieramonte, M.; Bianchini, C.; Bitzes, G.; Brun, R.; Canal, P.; Carminati, F.; de Fine Licht, J.; Duhem, L.; Elvira, D.; Gheata, A.; Jun, S. Y.; Lima, G.; Novak, M.; Presbyterian, M.; Shadura, O.; Seghal, R.; Wenzel, S.

    2015-12-01

    The recent emergence of hardware architectures characterized by many-core or accelerated processors has opened new opportunities for concurrent programming models taking advantage of both SIMD and SIMT architectures. The GeantV vector prototype for detector simulations has been designed to exploit both the vector capability of mainstream CPUs and multi-threading capabilities of coprocessors including NVidia GPUs and Intel Xeon Phi. The characteristics of these architectures are very different in terms of the vectorization depth, parallelization needed to achieve optimal performance or memory access latency and speed. An additional challenge is to avoid the code duplication often inherent to supporting heterogeneous platforms. In this paper we present the first experience of vectorizing electromagnetic physics models developed for the GeantV project.

  18. First experience of vectorizing electromagnetic physics models for detector simulation

    Energy Technology Data Exchange (ETDEWEB)

    Amadio, G. [Sao Paulo State U.; Apostolakis, J. [CERN; Bandieramonte, M. [Catania Astrophys. Observ.; Bianchini, C. [Mackenzie Presbiteriana U.; Bitzes, G. [CERN; Brun, R. [CERN; Canal, P. [Fermilab; Carminati, F. [CERN; Licht, J.de Fine [U. Copenhagen (main); Duhem, L. [Intel, Santa Clara; Elvira, D. [Fermilab; Gheata, A. [CERN; Jun, S. Y. [Fermilab; Lima, G. [Fermilab; Novak, M. [CERN; Presbyterian, M. [Bhabha Atomic Res. Ctr.; Shadura, O. [CERN; Seghal, R. [Bhabha Atomic Res. Ctr.; Wenzel, S. [CERN

    2015-12-23

    The recent emergence of hardware architectures characterized by many-core or accelerated processors has opened new opportunities for concurrent programming models taking advantage of both SIMD and SIMT architectures. The GeantV vector prototype for detector simulations has been designed to exploit both the vector capability of mainstream CPUs and multi-threading capabilities of coprocessors including NVidia GPUs and Intel Xeon Phi. The characteristics of these architectures are very different in terms of the vectorization depth, parallelization needed to achieve optimal performance or memory access latency and speed. An additional challenge is to avoid the code duplication often inherent to supporting heterogeneous platforms. In this paper we present the first experience of vectorizing electromagnetic physics models developed for the GeantV project.

  19. Final Report: BaBar Detector and Experimental at SLAC, September 30, 1998 - September 29, 1999

    International Nuclear Information System (INIS)

    Judd, Dennis J.

    2000-01-01

    The Prairie View AandM University High Energy Physics Group with its contingent of three undergraduates physics majors, joined the BaBar Collaboration at SLAC in September 1994. BaBar is the experiment and detector running in the PEP-II ring at SLAC as part of the Asymmetric B Factory project there to study CP violation and heavy flavor physics. The focus of our effort before this year was with the Muon/Neutral Hadron Detector/Instrumented Flux Return (IFD) subgroup within the BaBar collaboration, and particularly with the GEANT simulation of the IFR-. With the GEANT3 simulation essentially FR-ozen, and the GEANT4 full simulation of the IFR- done, we have decided to redirect our efforts toward other areas

  20. Final Report BaBar Detector and Experimental at SLAC, September 30, 1998 - September 29, 1999

    CERN Document Server

    Judd, D J

    2000-01-01

    The Prairie View AandM University High Energy Physics Group with its contingent of three undergraduates physics majors, joined the BaBar Collaboration at SLAC in September 1994. BaBar is the experiment and detector running in the PEP-II ring at SLAC as part of the Asymmetric B Factory project there to study CP violation and heavy flavor physics. The focus of our effort before this year was with the Muon/Neutral Hadron Detector/Instrumented Flux Return (IFD) subgroup within the BaBar collaboration, and particularly with the GEANT simulation of the IFR-. With the GEANT3 simulation essentially FR-ozen, and the GEANT4 full simulation of the IFR- done, we have decided to redirect our efforts toward other areas.

  1. The study of the particle trajectories in the magnetic fields of MARUSYA setup using GEANT 3 package

    International Nuclear Information System (INIS)

    Argintaru, Danut; Besliu, Calin; Jipa, Alexandru; Esanu, Tiberiu; Calin, Marius; Argintaru, Cristina

    2005-01-01

    Using the GEANT 3 package we simulate the trajectories of the detected particles in the MARUSYA (JINR Dubna) setup. The dependence between the particle momenta and TOF, dE/dx, velocities and angles are important both for the detectors design and particle identification (PID). (authors)

  2. Detailed GEANT description of the SDC central calorimeters

    International Nuclear Information System (INIS)

    Glagolev, V.V.; Li, W.

    1994-01-01

    This article represents the very detailed simulation model of the SDC central calorimeters and some results which were obtained using that model. The central calorimeters structure was coded on the GEANT 3.15 base in the frame of the SDCSIM environment. The SDCSIM is the general shell for simulation of the SDC set-up. The calorimeters geometry has been coded according to the FNAL and ANL engineering drawings and engineering data file. SDC central calorimeters detailed description is extremely useful for different simulation tasks, for fast simulation program parameters tuning, for different geometry especially studying (local response nonuniformity from bulkheads in the e.m. calorimeter and from coil supports and many others) and for the interpretation of the experimental data from the calorimeters. This simulation model is very useful for tasks of the test beam modules calorimeter calibration and for calorimeter in situ calibration. 3 refs., 8 figs

  3. GEANT4 simulation of the neutron background of the C{sub 6}D{sub 6} set-up for capture studies at n{sub T}OF

    Energy Technology Data Exchange (ETDEWEB)

    Žugec, P., E-mail: pzugec@phy.hr [Department of Physics, Faculty of Science, University of Zagreb (Croatia); Colonna, N. [Istituto Nazionale di Fisica Nucleare, Bari (Italy); Bosnar, D. [Department of Physics, Faculty of Science, University of Zagreb (Croatia); Altstadt, S. [Johann-Wolfgang-Goethe Universität, Frankfurt (Germany); Andrzejewski, J. [Uniwersytet Łódzki, Lodz (Poland); Audouin, L. [Centre National de la Recherche Scientifique/IN2P3 – IPN, Orsay (France); Barbagallo, M. [Istituto Nazionale di Fisica Nucleare, Bari (Italy); Bécares, V. [Centro de Investigaciones Energeticas Medioambientales y Tecnológicas (CIEMAT), Madrid (Spain); Bečvář, F. [Charles University, Prague (Czech Republic); Belloni, F. [Commissariat à l' Énergie Atomique (CEA) Saclay – Irfu, Gif-sur-Yvette (France); Berthoumieux, E. [Commissariat à l' Énergie Atomique (CEA) Saclay – Irfu, Gif-sur-Yvette (France); European Organization for Nuclear Research (CERN), Geneva (Switzerland); Billowes, J. [University of Manchester, Oxford Road, Manchester (United Kingdom); Boccone, V.; Brugger, M.; Calviani, M. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Calviño, F. [Universitat Politecnica de Catalunya, Barcelona (Spain); Cano-Ott, D. [Centro de Investigaciones Energeticas Medioambientales y Tecnológicas (CIEMAT), Madrid (Spain); Carrapiço, C. [Instituto Tecnológico e Nuclear, Instituto Superior Técnico, Universidade Técnica de Lisboa, Lisboa (Portugal); Cerutti, F. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); and others

    2014-10-01

    The neutron sensitivity of the C{sub 6}D{sub 6} detector setup used at n{sub T}OF facility for capture measurements has been studied by means of detailed GEANT4 simulations. A realistic software replica of the entire n{sub T}OF experimental hall, including the neutron beam line, sample, detector supports and the walls of the experimental area has been implemented in the simulations. The simulations have been analyzed in the same manner as experimental data, in particular by applying the Pulse Height Weighting Technique. The simulations have been validated against a measurement of the neutron background performed with a {sup nat}C sample, showing an excellent agreement above 1 keV. At lower energies, an additional component in the measured {sup nat}C yield has been discovered, which prevents the use of {sup nat}C data for neutron background estimates at neutron energies below a few hundred eV. The origin and time structure of the neutron background have been derived from the simulations. Examples of the neutron background for two different samples are demonstrating the important role of accurate simulations of the neutron background in capture cross-section measurements.

  4. Modeling of very low frequency (VLF radio wave signal profile due to solar flares using the GEANT4 Monte Carlo simulation coupled with ionospheric chemistry

    Directory of Open Access Journals (Sweden)

    S. Palit

    2013-09-01

    Full Text Available X-ray photons emitted during solar flares cause ionization in the lower ionosphere (~60 to 100 km in excess of what is expected to occur due to a quiet sun. Very low frequency (VLF radio wave signals reflected from the D-region of the ionosphere are affected by this excess ionization. In this paper, we reproduce the deviation in VLF signal strength during solar flares by numerical modeling. We use GEANT4 Monte Carlo simulation code to compute the rate of ionization due to a M-class flare and a X-class flare. The output of the simulation is then used in a simplified ionospheric chemistry model to calculate the time variation of electron density at different altitudes in the D-region of the ionosphere. The resulting electron density variation profile is then self-consistently used in the LWPC code to obtain the time variation of the change in VLF signal. We did the modeling of the VLF signal along the NWC (Australia to IERC/ICSP (India propagation path and compared the results with observations. The agreement is found to be very satisfactory.

  5. Condensed matter applied atomic collision physics, v.4

    CERN Document Server

    Datz, Sheldon

    1983-01-01

    Applied Atomic Collision Physics, Volume 4: Condensed Matter deals with the fundamental knowledge of collision processes in condensed media.The book focuses on the range of applications of atomic collisions in condensed matter, extending from effects on biological systems to the characterization and modification of solids. This volume begins with the description of some aspects of the physics involved in the production of ion beams. The radiation effects in biological and chemical systems, ion scattering and atomic diffraction, x-ray fluorescence analysis, and photoelectron and Auger spectrosc

  6. Abstract ID: 103 GAMOS: Implementation of a graphical user interface for dosimetry calculation in radiotherapy.

    Science.gov (United States)

    Abdalaoui Slimani, Faical Alaoui; Bentourkia, M'hamed

    2018-01-01

    There are several computer programs or combination of programs for radiation tracking and other information in tissues by using Monte Carlo simulation [1]. Among these are GEANT4 [2] programs provided as classes that can be incorporated in C++ codes to achieve different tasks in radiation interactions with matter. GEANT4 made the physics easier but requires often a long learning-curve that implies a good knowledge of C++ and the Geant4 architecture. GAMOS [3], the Geant4-based Architecture for Medicine-Oriented Simulations, facilitates the use of Geant4 by providing a script language that covers almost all the needs of a radiotherapy simulation but it is obviously out of reach of biological researchers. The aim of the present work was to report the design and development of a Graphical User Interface (GUI) for absorbed dose calculation and for particle tracking in humans, small animals and phantoms. The GUI is based on the open source GEANT4 for the physics of particle interactions, on the QT cross-platform application for combining programming commands and for display. The calculation of the absorbed dose can be performed based on 3D CT images in DICOM format, from images of phantoms or from solid volumes that can be made from any pure or composite material to be specified by its molecular formulas. The GUI has several menus relative to the emitting source which can have different shapes, positions, energy as mono- or poly-energy such as X-ray spectra; the types of particles and particle interactions; energy deposition and absorbed dose; and the output results as histograms. In conclusion, the GUI we developed can be easily used by any researcher without the need to be familiar with computer programming, and it will be freely proposed as an open source. Copyright © 2017.

  7. Benchmarking the Geant4 full system simulation of an associated alpha-particle detector for use in a D-T neutron generator.

    Science.gov (United States)

    Zhang, Xiaodong; Hayward, Jason P; Cates, Joshua W; Hausladen, Paul A; Laubach, Mitchell A; Sparger, Johnathan E; Donnald, Samuel B

    2012-08-01

    The position-sensitive alpha-particle detector used to provide the starting time and initial direction of D-T neutrons in a fast-neutron imaging system was simulated with a Geant4-based Monte Carlo program. The whole detector system, which consists of a YAP:Ce scintillator, a fiber-optic faceplate, a light guide, and a position-sensitive photo-multiplier tube (PSPMT), was modeled, starting with incident D-T alphas. The scintillation photons, whose starting time follows the distribution of a scintillation decay curve, were produced and emitted uniformly into a solid angle of 4π along the track segments of the alpha and its secondaries. Through tracking all photons and taking into account the quantum efficiency of the photocathode, the number of photoelectrons and their time and position distributions were obtained. Using a four-corner data reconstruction formula, the flood images of the alpha detector with and without optical grease between the YAP scintillator and the fiber-optic faceplate were obtained, which show agreement with the experimental results. The reconstructed position uncertainties of incident alpha particles for both cases are 1.198 mm and 0.998 mm respectively across the sensitive area of the detector. Simulation results also show that comparing with other faceplates composed of 500 μm, 300 μm, and 100 μm fibers, the 10-μm-fiber faceplate is the best choice to build the detector for better position performance. In addition, the study of the background originating inside the D-T generator suggests that for 500-μm-thick YAP:Ce coated with 1-μm-thick aluminum, and very good signal-to-noise ratio can be expected through application of a simple threshold. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. The effect of 111In radionuclide distance and auger electron energy on direct induction of DNA double-strand breaks: a Monte Carlo study using Geant4 toolkit.

    Science.gov (United States)

    Piroozfar, Behnaz; Raisali, Gholamreza; Alirezapour, Behrouz; Mirzaii, Mohammad

    2018-04-01

    In this study, the effect of 111 In position and Auger electron energy on direct induction of DSBs was investigated. The Geant4-DNA simulation toolkit was applied using a simple B-DNA form extracted from PDBlib library. First, the simulation was performed for electrons with energies of 111 In and equal emission probabilities to find the most effective electron energies. Then, 111 In Auger electrons' actual spectrum was considered and their contribution in DSB induction analysed. The results showed that the most effective electron energy is 183 eV, but due to the higher emission probability of 350 eV electrons, most of the DSBs were induced by the latter electrons. Also, it was observed that most of the DSBs are induced by electrons emitted within 4 nm of the central axis of the DNA and were mainly due to breaks with <4 base pairs distance in opposing strands. Whilst, when 111 In atoms are very close to the DNA, 1.3 DSBs have been obtained per decay of 111 In atoms. The results show that the most effective Auger electrons are the 350 eV electrons from 111 In atoms with <4 nm distance from the central axis of the DNA which induce ∼1.3 DSBs per decay when bound to the DNA. This value seems reasonable when compared with the reported experimental data.

  9. Lateral variations of radiobiological properties of therapeutic fields of 1H, 4He, 12C and 16O ions studied with Geant4 and microdosimetric kinetic model

    Science.gov (United States)

    Dewey, Sophie; Burigo, Lucas; Pshenichnov, Igor; Mishustin, Igor; Bleicher, Marcus

    2017-07-01

    As known, in cancer therapy with ion beams the relative biological effectiveness (RBE) of ions changes in the course of their propagation in tissues. Such changes are caused not only by increasing the linear energy transfer (LET) of beam particles with the penetration depth towards the Bragg peak, but also by nuclear reactions induced by beam nuclei leading to the production of various secondary particles. Although the changes of RBE along the beam axis have been studied quite well, much less attention has been paid to the evolution of RBE in the transverse direction, perpendicular to the beam axis. In order to fill this gap, we simulated radiation fields of 1H, 4He, 12C and 16O nuclei of 20 mm in diameter by means of a Geant4-based Monte Carlo model for heavy-ion therapy connected with the modified microdosimetric kinetic model to describe the response of normal ((α/β)_x-rays=3.8 Gy) and early-responding ((α/β)_x-rays=10 Gy) tissues. Depth and radial distributions of saturation-corrected dose-mean lineal energy, RBE and RBE-weighted dose are investigated for passive beam shaping and active beam scanning. The field of 4He has a small lateral spread as compared with 1H field, and it is characterised by a modest lateral variation of RBE suggesting the use of fixed RBE values across the field transverse cross section at each depth. Reduced uncertainties of RBE on the boundary of a 4He treatment field can be advantageous in a specific case of an organ at risk located in lateral proximity to the target volume. It is found that the lateral distributions of RBE calculated for 12C and 16O fields demonstrate fast variations in the radial direction due to changes of dose and composition of secondary fragments in the field penumbra. Nevertheless, the radiation fields of all four projectiles at radii larger than 20 mm can be characterized by a common RBE value defined by tissue radiosensitivity. These findings can help, in particular, in accessing the transverse

  10. Composing Models of Geographic Physical Processes

    Science.gov (United States)

    Hofer, Barbara; Frank, Andrew U.

    Processes are central for geographic information science; yet geographic information systems (GIS) lack capabilities to represent process related information. A prerequisite to including processes in GIS software is a general method to describe geographic processes independently of application disciplines. This paper presents such a method, namely a process description language. The vocabulary of the process description language is derived formally from mathematical models. Physical processes in geography can be described in two equivalent languages: partial differential equations or partial difference equations, where the latter can be shown graphically and used as a method for application specialists to enter their process models. The vocabulary of the process description language comprises components for describing the general behavior of prototypical geographic physical processes. These process components can be composed by basic models of geographic physical processes, which is shown by means of an example.

  11. Measurements and Monte-Carlo simulations of the particle self-shielding effect of B4C grains in neutron shielding concrete

    Science.gov (United States)

    DiJulio, D. D.; Cooper-Jensen, C. P.; Llamas-Jansa, I.; Kazi, S.; Bentley, P. M.

    2018-06-01

    A combined measurement and Monte-Carlo simulation study was carried out in order to characterize the particle self-shielding effect of B4C grains in neutron shielding concrete. Several batches of a specialized neutron shielding concrete, with varying B4C grain sizes, were exposed to a 2 Å neutron beam at the R2D2 test beamline at the Institute for Energy Technology located in Kjeller, Norway. The direct and scattered neutrons were detected with a neutron detector placed behind the concrete blocks and the results were compared to Geant4 simulations. The particle self-shielding effect was included in the Geant4 simulations by calculating effective neutron cross-sections during the Monte-Carlo simulation process. It is shown that this method well reproduces the measured results. Our results show that shielding calculations for low-energy neutrons using such materials would lead to an underestimate of the shielding required for a certain design scenario if the particle self-shielding effect is not included in the calculations.

  12. A visual user interface program, EGSWIN, for EGS4

    International Nuclear Information System (INIS)

    Qiu Rui; Li Junli; Wu Zhen

    2005-01-01

    To overcome the inconvenience and difficulty in using the EGS4 code by novice users, a visual user interface program, called the EGSWIN system, has been developed by the Monte Carlo Research Center of Tsinghua University in China. EGSWIN allows users to run EGS4 for many applications without any user coding. A mixed-language programming technique with Visual C++ and Visual Fortran is used in order to embed both EGS4 and PEGS4 into EGSWIN. The system has the features of visual geometry input, geometry processing, visual definitions of source, scoring and computing parameters, and particle trajectories display. Comparison between the calculated results with EGS4 and EGSWIN, as well as with FLUKA and GEANT, has been made to validate EGSWIN. (author)

  13. Levels of processing and picture memory: the physical superiority effect.

    Science.gov (United States)

    Intraub, H; Nicklos, S

    1985-04-01

    Six experiments studied the effect of physical orienting questions (e.g., "Is this angular?") and semantic orienting questions (e.g., "Is this edible?") on memory for unrelated pictures at stimulus durations ranging from 125-2,000 ms. Results ran contrary to the semantic superiority "rule of thumb," which is based primarily on verbal memory experiments. Physical questions were associated with better free recall and cued recall of a diverse set of visual scenes (Experiments 1, 2, and 4). This occurred both when general and highly specific semantic questions were used (Experiments 1 and 2). Similar results were obtained when more simplistic visual stimuli--photographs of single objects--were used (Experiments 5 and 6). As in the case of the semantic superiority effect with words, the physical superiority effect for pictures was eliminated or reversed when the same physical questions were repeated throughout the session (Experiments 4 and 6). Conflicts with results of previous levels of processing experiments with words and nonverbal stimuli (e.g., faces) are explained in terms of the sensory-semantic model (Nelson, Reed, & McEvoy, 1977). Implications for picture memory research and the levels of processing viewpoint are discussed.

  14. Application of the GEANT3 geometry package to the description of the OPAL detector

    Energy Technology Data Exchange (ETDEWEB)

    Allison, J; Brun, R; Bruyant, F; Zanarini, P; Bullock, F W; Hobson, P R; Chang, C Y; Dumont, J J; Hemingway, R J; McPherson, A C

    1987-10-01

    We present the general features of the GEANT3 package for coding the geometrical structure of a large and complex detector in the computer programs used for their design and analysis. This package has been developed in the context of Monte Carlo studies of detector performance but should be well matched to the problem of analysis. As a specific example, we illustrate the description of the OPAL detector for the Large Electron Positron collider at CERN and show the results of a sample study using this description.

  15. Multiphoton Processes and Attosecond Physics

    CERN Document Server

    Midorikawa, Katsumi; 12th International Conference on Multiphoton Processes; 3rd International Conference on Attosecond Physics

    2012-01-01

    Recent advances in ultrashort pulsed laser technology have opened new frontiers in atomic, molecular and optical sciences. The 12th International Conference on Multiphoton Processes (ICOMP12) and the 3rd International Conference on Attosecond Physics (ATTO3), held jointly in Sapporo, Japan, during July 3-8, showcased studies at the forefront of research on multiphoton processes and attosecond physics. This book summarizes presentations and discussions from these two conferences.

  16. GEANT4 hadronic cascade models analysis of proton and charged pion transverse momentum spectra from p plus Cu and Pb collisions at 3, 8, and 15 GeV/c

    CERN Document Server

    Abdel-Waged, Khaled; Uzhinskii, V V

    2011-01-01

    We describe how various hadronic cascade models, which are implemented in the GEANT4 toolkit, describe proton and charged pion transverse momentum spectra from p + Cu and Pb collisions at 3, 8, and 15 GeV/c, recently measured in the hadron production (HARP) experiment at CERN. The Binary, ultrarelativistic quantum molecular dynamics (UrQMD) and modified FRITIOF (FTF) hadronic cascade models are chosen for investigation. The first two models are based on limited (Binary) and branched (UrQMD) binary scattering between cascade particles which can be either a baryon or meson, in the three-dimensional space of the nucleus, while the latter (FTF) considers collective interactions between nucleons only, on the plane of impact parameter. It is found that the slow (p(T) 0.3 GeV/c) proton spectra are not strongly affected by the differences between the FTF and UrQMD models. It is also shown that the UrQMD and FTF combined with Binary (FTFB) models could reproduce both proton and charged pion spectra from p + Cu and Pb...

  17. A system for designing and simulating particle physics experiments

    International Nuclear Information System (INIS)

    Zelazny, R.; Strzalkowski, P.

    1987-01-01

    In view of the rapid development of experimental facilities and their costs, the systematic design and preparation of particle physics experiments have become crucial. A software system is proposed as an aid for the experimental designer, mainly for experimental geometry analysis and experimental simulation. The following model is adopted: the description of an experiment is formulated in a language (here called XL) and put by its processor in a data base. The language is based on the entity-relationship-attribute approach. The information contained in the data base can be reported and analysed by an analyser (called XA) and modifications can be made at any time. In particular, the Monte Carlo methods can be used in experiment simulation for both physical phenomena in experimental set-up and detection analysis. The general idea of the system is based on the design concept of ISDOS project information systems. The characteristics of the simulation module are similar to those of the CERN Geant system, but some extensions are proposed. The system could be treated as a component of greater, integrated software environment for the design of particle physics experiments, their monitoring and data processing. (orig.)

  18. Nuclear Data Processing for Reactor Physics Calculation

    International Nuclear Information System (INIS)

    Suwoto; Zuhair; Pandiangan, Tumpal

    2003-01-01

    Nuclear data processing for reactor physics calculation has been done. Raw nuclear data cross-sections on file ENDF should be prepared and processed before it used in neutronic calculation. The processing code system such as NJOY-PC code has been used from linearization of nuclear cross-sections data and background contribution of resonance parameter (MF2) using RECONR module (0K) with energy range from 10 -5 to 10 7 eV. Afterward, the neutron cross-sections data should be processed and broadened to desire temperature (i.e. 293K) by using BROADR module. The Grouper and Therma modules will be applied for multi-groups calculation which suitable for WIMS/D4 (69 groups) and thermalization of nuclear constants. The final stage of processing nuclear cross-sections is updating WIMS/D4 library. The WIMSR module in NJOY-PC and WILLIE code will be applied in this stage. The evaluated nuclear data file, especially for 1 H 1 isotope, was taken from JENDL-3.2 and ENDF/B-VI for preliminary study. The results of nuclear data processing 1 H 1 shows that the old-WIMS (WIMS-lama) library have much discrepancies comparing with JENDL-3.2 or ENDF/B-VI files, especially in energy around 5 keV

  19. Calculation of direct effects of {sup 60}Co gamma rays on the different DNA structural levels: A simulation study using the Geant4-DNA toolkit

    Energy Technology Data Exchange (ETDEWEB)

    Tajik, Marjan; Rozatian, Amir S.H. [Department of Physics, University of Isfahan, Hezar Jarib Street, Isfahan 81746-73441 (Iran, Islamic Republic of); Semsarha, Farid, E-mail: Semsarha@ibb.ut.ac.ir [Institute of Biochemistry and Biophysics (IBB), University of Tehran, P.O. Box: 13145-1384, Tehran (Iran, Islamic Republic of)

    2015-03-01

    In this study, simple single strand breaks (SSB) and double strand breaks (DSB) due to direct effects of the secondary electron spectrum of {sup 60}Co gamma rays on different organizational levels of a volume model of the B-DNA conformation have been calculated using the Geant4-DNA toolkit. Result of this study for the direct DSB yield shows a good agreement with other theoretical and experimental results obtained by both photons and their secondary electrons; however, in the case of SSB a noticeable difference can be observed. Moreover, regarding the almost constant yields of the direct strand breaks in the different structural levels of the DNA, calculated in this work, and compared with some theoretical studies, it can be deduced that the direct strand breaks yields depend mainly on the primary double helix structure of the DNA and the higher-order structures cannot have a noticeable effect on the direct DNA damage inductions by {sup 60}Co gamma rays. In contrast, a direct dependency between the direct SSB and DSB yields and the volume of the DNA structure has been found. Also, a further study on the histone proteins showed that they can play an important role in the trapping of low energy electrons without any significant effect on the direct DNA strand breaks inductions, at least in the range of energies used in the current study.

  20. Monte Carlo simulation of tomography techniques using the platform Gate

    International Nuclear Information System (INIS)

    Barbouchi, Asma

    2007-01-01

    Simulations play a key role in functional imaging, with applications ranging from scanner design, scatter correction, protocol optimisation. GATE (Geant4 for Application Tomography Emission) is a platform for Monte Carlo Simulation. It is based on Geant4 to generate and track particles, to model geometry and physics process. Explicit modelling of time includes detector motion, time of flight, tracer kinetics. Interfaces to voxellised models and image reconstruction packages improve the integration of GATE in the global modelling cycle. In this work Monte Carlo simulations are used to understand and optimise the gamma camera's performances. We study the effect of the distance between source and collimator, the diameter of the holes and the thick of the collimator on the spatial resolution, energy resolution and efficiency of the gamma camera. We also study the reduction of simulation's time and implement a model of left ventricle in GATE. (Author). 7 refs

  1. Packaging Effects on RadFET Sensors for High Energy Physics Experiments

    CERN Document Server

    Mekki, J; Glaser, M; Guatelli, S; Moll, M; Pia, M G; Ravotti, F

    2009-01-01

    RadFETs in customized chip carrier packages are installed in the LHC Experiments as radiation monitors. The package influence on the dose measurement in the complex LHC radiation environment is evaluated using Geant4 simulations and experimental data.

  2. An application of the GEANT3 geometry package to the description of the OPAL detector

    International Nuclear Information System (INIS)

    Allison, J.; Bullock, F.W.; Hobson, P.R.; Lorazo, B.; Mallet, J.; Patrick, G.; Possoz, A.; Rossi, A.; Bologna Univ.; Ward, D.R.; Ward, C.P.

    1987-01-01

    We present the general features of the GEANT3 package for coding the geometrical structure of a large and complex detector in the computer programs used for their design and analysis. This package has been developed in the context of Monte Carlo studies of detector performance but should be well matched to the problem of analysis. As a specific example, we illustrate the description of the OPAL detector for the Large Electron Positron collider at CERN and show the results of a sample study using this description. (orig.)

  3. A GEANT4 Monte-Carlo simulation code for precision beta spectroscopy

    Czech Academy of Sciences Publication Activity Database

    Wauters, F.; Kraev, I.; Zákoucký, Dalibor; Beck, M.; Golovko, V. V.; Kozlov, V. Yu.; Phalet, T.; Tandecki, M.; Traykov, E.; Van Gorp, S.; Severijns, N.

    2009-01-01

    Roč. 609, 2-3 (2009), s. 156-164 ISSN 0168-9002 Institutional research plan: CEZ:AV0Z10480505 Keywords : beta decay * nuclei * electrons Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.317, year: 2009

  4. CA/CPS: A Communications ZEBRA implementation using CPS

    International Nuclear Information System (INIS)

    Roberts, L.A.

    1991-05-01

    CZ/CPS is an implementation of the Communications ZEBRA distributed computing environment utilizing the CPS communications protocol. CZ/CPS is intended for parallelization of high energy physics application programs using the CERN Program Library memory and data structure management features. CZ/CPS provides transparent communication of ZEBRA data structures among cooperative processes using standard interfaces for ZEBRA I/O. Examples of usage in a CPS HBOOK4 and GEANT3 application are provided

  5. Simulation of photofission experiments at the ELI-NP facility

    International Nuclear Information System (INIS)

    Constantin, P.; Balabanski, D.L.; Cuong, P.V.

    2016-01-01

    An extensive experimental program for the study of photofission will take place at the Extreme Light Infrastructure – Nuclear Physics (ELI-NP) facility, where different actinide targets will be exposed to a brilliant gamma beam to produce fission fragments. We report on the implementation within the Geant4 simulation toolkit of the photofission process, of related background processes, and of extended ionic charge parameterization. These developments are used to evaluate the production rates of photofission fragments and their release efficiency from the actinide targets.

  6. Simulation of secondary emission calorimeter for future colliders

    Science.gov (United States)

    Yetkin, E. A.; Yetkin, T.; Ozok, F.; Iren, E.; Erduran, M. N.

    2018-03-01

    We present updated results from a simulation study of a conceptual sampling electromagnetic calorimeter based on secondary electron emission process. We implemented the secondary electron emission process in Geant4 as a user physics list and produced the energy spectrum and yield of secondary electrons. The energy resolution of the SEE calorimeter was σ/E = (41%) GeV1/2/√E and the response linearity to electromagnetic showers was to within 1.5%. The simulation results were also compared with a traditional scintillator calorimeter.

  7. Simulation of photofission experiments at the ELI-NP facility

    Energy Technology Data Exchange (ETDEWEB)

    Constantin, P., E-mail: paul.constantin@eli-np.ro [Extreme Light Infrastructure – Nuclear Physics, “Horia Hulubei” National Institute for Physics and Nuclear Engineering, Str. Reactorului 30, 077125 Bucharest Magurele (Romania); Balabanski, D.L. [Extreme Light Infrastructure – Nuclear Physics, “Horia Hulubei” National Institute for Physics and Nuclear Engineering, Str. Reactorului 30, 077125 Bucharest Magurele (Romania); Cuong, P.V. [Centre of Nuclear Physics, Institute of Physics, Vietnam Academy of Science and Technology, Hanoi (Viet Nam)

    2016-04-01

    An extensive experimental program for the study of photofission will take place at the Extreme Light Infrastructure – Nuclear Physics (ELI-NP) facility, where different actinide targets will be exposed to a brilliant gamma beam to produce fission fragments. We report on the implementation within the Geant4 simulation toolkit of the photofission process, of related background processes, and of extended ionic charge parameterization. These developments are used to evaluate the production rates of photofission fragments and their release efficiency from the actinide targets.

  8. Dynamical processes in atomic and molecular physics

    CERN Document Server

    Ogurtsov, Gennadi

    2012-01-01

    Atomic and molecular physics underlie a basis for our knowledge of fundamental processes in nature and technology and in such applications as solid state physics, chemistry and biology. In recent years, atomic and molecular physics has undergone a revolutionary change due to great achievements in computing and experimental techniques. As a result, it has become possible to obtain information both on atomic and molecular characteristics and on dynamics of atomic and molecular processes. This e-book highlights the present state of investigations in the field of atomic and molecular physics. Rece

  9. Transport processes in space physics and astrophysics

    CERN Document Server

    Zank, Gary P

    2014-01-01

    Transport Processes in Space Physics and Astrophysics' is aimed at graduate level students to provide the necessary mathematical and physics background to understand the transport of gases, charged particle gases, energetic charged particles, turbulence, and radiation in an astrophysical and space physics context. Subjects emphasized in the work include collisional and collisionless processes in gases (neutral or plasma), analogous processes in turbulence fields and radiation fields, and allows for a simplified treatment of the statistical description of the system. A systematic study that addresses the common tools at a graduate level allows students to progress to a point where they can begin their research in a variety of fields within space physics and astrophysics. This book is for graduate students who expect to complete their research in an area of plasma space physics or plasma astrophysics. By providing a broad synthesis in several areas of transport theory and modeling, the work also benefits resear...

  10. Pramana – Journal of Physics | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    Angular distribution of cosmic-ray muons at sea level has been investigated using the Geant4 simulation package. The model used in the simulations was tested by comparing the simulation results with the measurements made using the Berkeley Lab cosmic ray detector. Primary particles' energy and fluxes were obtained ...

  11. Exoplanet atmospheres physical processes

    CERN Document Server

    Seager, Sara

    2010-01-01

    Over the past twenty years, astronomers have identified hundreds of extrasolar planets--planets orbiting stars other than the sun. Recent research in this burgeoning field has made it possible to observe and measure the atmospheres of these exoplanets. This is the first textbook to describe the basic physical processes--including radiative transfer, molecular absorption, and chemical processes--common to all planetary atmospheres, as well as the transit, eclipse, and thermal phase variation observations that are unique to exoplanets. In each chapter, Sara Seager offers a conceptual introduction, examples that combine the relevant physics equations with real data, and exercises. Topics range from foundational knowledge, such as the origin of atmospheric composition and planetary spectra, to more advanced concepts, such as solutions to the radiative transfer equation, polarization, and molecular and condensate opacities. Since planets vary widely in their atmospheric properties, Seager emphasizes the major p...

  12. Advances in Astroparticle Physics (4/5)

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    Astroparticle physics is in an era of rapid progress. New observations challenge theory on several different fronts. We will analyze a few prominent examples, putting special emphasis on the connection with fundamental particle physics. Session 4. Interpreting IceCube’s neutrinos

  13. The implementation of full ATLAS detector simulation program

    International Nuclear Information System (INIS)

    Rimoldi, A.; Dell'Acqua, A.; Stavrianakou, M.; Amako, K.; Kanzaki, J.; Morita, Y.; Murakami, K.; Sasaki, T.; Saeki, T.; Ueda, I.; Tanaka, S.; Yoshida, H.

    2001-01-01

    The ATLAS detector is one of the most sophisticated and huge detectors ever designed up to now. A detailed, flexible and complete simulation program is needed in order to study the characteristics and possible problems of such a challenging apparatus and to answer to all raising questions in terms of physics, design optimization, etc. To cope with these needs the authors are implementing an application based on the simulation framework FADS/Goofy (Framework for ATLAS Detector Simulation /Geant4-based Object-Oriented Folly) in the Geant4 environment. The user's specific code implementation is presented in details for the different applications implemented until now, from the various components of the ATLAS spectrometer to some particular testbeam facilities. Particular emphasis is put in describing the simulation of the Muon Spectrometer and its subsystems as a test case for the implementation of the whole detector simulation program: the intrinsic complexity in the geometry description of the Muon System is one of the more demanding problems that are faced. The magnetic field handling, the physics impact in the event processing in presence of backgrounds from different sources and the implementation of different possible generators (including Pythia) are also discussed

  14. Spin physics and inclusive processes at short distances

    International Nuclear Information System (INIS)

    Craigie, N.S.

    1982-10-01

    The following aspects of spin physics at short distances are studied: 1. the factorization theorem in perturbative QCD and helicity asymmetries in inclusive processes, 2. the effect of higher order radiative corrections on helicity asymmetries, 3. the higher order power mechanism and spin asymmetries, 4. difficulties in understanding transverse spin in perturbative QCD, 5. helicity asymmetries of short distances as a means of recognizing supersymmetric interactions. Experiments are suggested for the verification of theoretical conclusions. Although spin-physics at short distances is difficult to demonstrate experimentally it may provide a valuable tool to show how perturbative QCD operates in the presence of the non-perturbative hadronic structure. It may also prove valuable to show new interactions which might occur at very short distances

  15. Geneva University: Experiments in Physics: Hands-on Creative Processes

    CERN Multimedia

    Université de Genève

    2011-01-01

    Geneva University Physics Department 24, quai Ernest-Ansermet CH-1211 Geneva 4 Tel: (022) 379 62 73 Fax: (022) 379 69 92   Lundi 3 octobre 2011, 17h00 Ecole de Physique, Auditoire Stueckelberg «Experiments in Physics : Hands-on Creative Processes» Prof. Manfred Euler Leibniz-Institute for Mathematics and Science Education (IPN) University of Kiel, Deutschland Experiments play a variety of different roles in knowledge generation. The lecture will focus on the function of experiments as engines of intuition that foster insights into complex processes. The experimental presentations consider self-organization phenomena in various domains that range from the nanomechanics of biomolecules to perception and cognition. The inherent universality contributes to elucidating the enigmatic phenomenon of creativity. Une verrée en compagnie du conférencier sera offerte après le colloque.       &...

  16. Laser isotope separation: the physics of the process

    International Nuclear Information System (INIS)

    Lapierre, Y.

    1990-01-01

    The physics of the AVLIS process is analysed. The intricacy of physics considerations, technology and economic forecast is developed. The scaling of a production unit is a complicated optimization which takes into account the limitations imposed by physics laws (spectroscopy, plasma physics,...), technology (vapor production, laser industry,...), and economy. But the only philosophy which prevails for such R and D programs is to be cheaper than competitive processes and to reach the goal first to get the market

  17. Physics at the AD/PS/SPS (4/4)

    CERN Multimedia

    CERN. Geneva

    2012-01-01

    Lecture 4: Physics with Antimatter at the Antiproton Decelerator The Antiproton Decelerator (AD) is a unique facility - the world's only source of low energy antiprotons for fundamental studies of the physics of antimatter. I will discuss the physics at the AD, with an emphasis on studies of antihydrogen, the only antimatter atom that we can produce in the laboratory. Recently we have been able to capture antihydrogen, store it for more than 15 minutes, and make the first measurements of its structure. The idea is to compare it to hydrogen, to see if atom and anti-atom behave identically, as required by the Standard Model. The AD was the inspiration for Dan Brown's 'Angels and Demons'; we can also take a look at the science fiction in the book.

  18. Monte Carlo Study of the abBA Experiment: Detector Response and Physics Analysis.

    Science.gov (United States)

    Frlež, E

    2005-01-01

    The abBA collaboration proposes to conduct a comprehensive program of precise measurements of neutron β-decay coefficients a (the correlation between the neutrino momentum and the decay electron momentum), b (the electron energy spectral distortion term), A (the correlation between the neutron spin and the decay electron momentum), and B (the correlation between the neutron spin and the decay neutrino momentum) at a cold neutron beam facility. We have used a GEANT4-based code to simulate the propagation of decay electrons and protons in the electromagnetic spectrometer and study the energy and timing response of a pair of Silicon detectors. We used these results to examine systematic effects and find the uncertainties with which the physics parameters a, b, A, and B can be extracted from an over-determined experimental data set.

  19. SU-E-T-22: A Deterministic Solver of the Boltzmann-Fokker-Planck Equation for Dose Calculation

    Energy Technology Data Exchange (ETDEWEB)

    Hong, X; Gao, H [Shanghai Jiao Tong University, Shanghai, Shanghai (China); Paganetti, H [Massachusetts General Hospital, Boston, MA (United States)

    2015-06-15

    Purpose: The Boltzmann-Fokker-Planck equation (BFPE) accurately models the migration of photons/charged particles in tissues. While the Monte Carlo (MC) method is popular for solving BFPE in a statistical manner, we aim to develop a deterministic BFPE solver based on various state-of-art numerical acceleration techniques for rapid and accurate dose calculation. Methods: Our BFPE solver is based on the structured grid that is maximally parallelizable, with the discretization in energy, angle and space, and its cross section coefficients are derived or directly imported from the Geant4 database. The physical processes that are taken into account are Compton scattering, photoelectric effect, pair production for photons, and elastic scattering, ionization and bremsstrahlung for charged particles.While the spatial discretization is based on the diamond scheme, the angular discretization synergizes finite element method (FEM) and spherical harmonics (SH). Thus, SH is used to globally expand the scattering kernel and FFM is used to locally discretize the angular sphere. As a Result, this hybrid method (FEM-SH) is both accurate in dealing with forward-peaking scattering via FEM, and efficient for multi-energy-group computation via SH. In addition, FEM-SH enables the analytical integration in energy variable of delta scattering kernel for elastic scattering with reduced truncation error from the numerical integration based on the classic SH-based multi-energy-group method. Results: The accuracy of the proposed BFPE solver was benchmarked against Geant4 for photon dose calculation. In particular, FEM-SH had improved accuracy compared to FEM, while both were within 2% of the results obtained with Geant4. Conclusion: A deterministic solver of the Boltzmann-Fokker-Planck equation is developed for dose calculation, and benchmarked against Geant4. Xiang Hong and Hao Gao were partially supported by the NSFC (#11405105), the 973 Program (#2015CB856000) and the Shanghai Pujiang

  20. Radiological/Health physics program assessement at Rocky Flats, the process

    International Nuclear Information System (INIS)

    Psomas, P.O.

    1996-01-01

    The Department of Energy, Rocky Flats Office, Safety and Health Group, Health Physics Team (HPT) is responsible for oversight of the Radiation Protection and Health Physics Program (RPHP) of the Integrating Management Contractor (IMC), Kaiser-Hill (K-H) operations at the Rocky Flats Environmental Technology Site (RFETS). As of 1 January 1996 the Rocky Flats Plant employed 300 DOE and 4,300 contractor personnel (K-H and their subcontractors). WSI is a subcontractor and provides plant security. To accomplish the RPHP program oversight HPT personnel developed a systematic methodology for performing a functional RPHP Assessment. The initial process included development of a flow diagram identifying all programmatic elements and assessment criteria documents. Formulation of plans for conducting interviews and performance of assessments constituted the second major effort. The generation of assessment reports was the final step, based on the results of this process. This assessment will be a 6 person-year effort, over the next three years. This process is the most comprehensive assessment of any Radiation Protection and Health Physics (RPHP) Program ever performed at Rocky Flats. The results of these efforts will establish a baseline for future RPHP Program assessments at RFETS. This methodology has been well-received by contractor personnel and creates no Privacy Act violations or other misunderstandings

  1. The revised APTA code of ethics for the physical therapist and standards of ethical conduct for the physical therapist assistant: theory, purpose, process, and significance.

    Science.gov (United States)

    Swisher, Laura Lee; Hiller, Peggy

    2010-05-01

    In June 2009, the House of Delegates (HOD) of the American Physical Therapy Association (APTA) passed a major revision of the APTA Code of Ethics for physical therapists and the Standards of Ethical Conduct for the Physical Therapist Assistant. The revised documents will be effective July 1, 2010. The purposes of this article are: (1) to provide a historical, professional, and theoretical context for this important revision; (2) to describe the 4-year revision process; (3) to examine major features of the documents; and (4) to discuss the significance of the revisions from the perspective of the maturation of physical therapy as a doctoring profession. PROCESS OF REVISION: The process for revision is delineated within the context of history and the Bylaws of APTA. FORMAT, STRUCTURE, AND CONTENT OF REVISED CORE ETHICS DOCUMENTS: The revised documents represent a significant change in format, level of detail, and scope of application. Previous APTA Codes of Ethics and Standards of Ethical Conduct for the Physical Therapist Assistant have delineated very broad general principles, with specific obligations spelled out in the Ethics and Judicial Committee's Guide for Professional Conduct and Guide for Conduct of the Physical Therapist Assistant. In contrast to the current documents, the revised documents address all 5 roles of the physical therapist, delineate ethical obligations in organizational and business contexts, and align with the tenets of Vision 2020. The significance of this revision is discussed within historical parameters, the implications for physical therapists and physical therapist assistants, the maturation of the profession, societal accountability and moral community, potential regulatory implications, and the inclusive and deliberative process of moral dialogue by which changes were developed, revised, and approved.

  2. Evaluation of Monte Carlo tools for high energy atmospheric physics

    Directory of Open Access Journals (Sweden)

    C. Rutjes

    2016-11-01

    Full Text Available The emerging field of high energy atmospheric physics (HEAP includes terrestrial gamma-ray flashes, electron–positron beams and gamma-ray glows from thunderstorms. Similar emissions of high energy particles occur in pulsed high voltage discharges. Understanding these phenomena requires appropriate models for the interaction of electrons, positrons and photons of up to 40 MeV energy with atmospheric air. In this paper, we benchmark the performance of the Monte Carlo codes Geant4, EGS5 and FLUKA developed in other fields of physics and of the custom-made codes GRRR and MC-PEPTITA against each other within the parameter regime relevant for high energy atmospheric physics. We focus on basic tests, namely on the evolution of monoenergetic and directed beams of electrons, positrons and photons with kinetic energies between 100 keV and 40 MeV through homogeneous air in the absence of electric and magnetic fields, using a low energy cutoff of 50 keV. We discuss important differences between the results of the different codes and provide plausible explanations. We also test the computational performance of the codes. The Supplement contains all results, providing a first benchmark for present and future custom-made codes that are more flexible in including electrodynamic interactions.

  3. Physical processes in the interstellar medium

    CERN Document Server

    Spitzer, Lyman

    2008-01-01

    Physical Processes in the Interstellar Medium discusses the nature of interstellar matter, with a strong emphasis on basic physical principles, and summarizes the present state of knowledge about the interstellar medium by providing the latest observational data. Physics and chemistry of the interstellar medium are treated, with frequent references to observational results. The overall equilibrium and dynamical state of the interstellar gas are described, with discussions of explosions produced by star birth and star death and the initial phases of cloud collapse leading to star formation.

  4. Physics of Laser Materials Processing Theory and Experiment

    CERN Document Server

    Gladush, Gennady G

    2011-01-01

    This book describes the basic mechanisms, theory, simulations and technological aspects of Laser processing techniques. It covers the principles of laser quenching, welding, cutting, alloying, selective sintering, ablation, etc. The main attention is paid to the quantitative description. The diversity and complexity of technological and physical processes is discussed using a unitary approach. The book aims on understanding the cause-and-effect relations in physical processes in Laser technologies. It will help researchers and engineers to improve the existing and develop new Laser machining techniques. The book addresses readers with a certain background in general physics and mathematical analysis: graduate students, researchers and engineers practicing laser applications.

  5. [The Process of Healing Child Physical Abuse: Sprouting and Twining].

    Science.gov (United States)

    Chang, Hsin-Yi; Feng, Jui-Ying; Tseng, Ren-Mei

    2018-06-01

    Child physical abuse impacts the physical and psychological health of survivors. Healing child abuse is an essential process that helps survivors reorganize the meaning of the trauma and pursue a normal life. Considering the trauma of child physical abuse within the social context allows the experiences of individual survivors to be reflected in their process of healing. To explore the social interaction and construction process of healing experienced by survivors of child physical abuse. A qualitative research design using grounded theory was applied. Purposive and theoretical sampling was used to recruit survivors of childhood physical abuse who had experienced healing. Semi-structured, in-depth interviews were used and data were analyzed using open, axial, and selective coding. The process of healing child physical abuse in this study was a process of sprouting and twining. Three core categories emerged: thriving, relationships, and ethics. The healing process was analogous to a seed growing in poor soil, sprouting out from the ground, and striving to live by seeking support. The survivors constantly established interactive relationships with their selves and with others and struggled to keep family bonds grounded and growing within the frame of ethics. The healing process of sprouting and twining for child physical abuse survivors in Taiwan integrates thriving, relationships, and ethics. Professionals working with child-physical-abuse survivors must recognize conflicts in ethics. Strategies should be developed to assist survivors to cope with the impact of childhood trauma in order to facilitate the healing process.

  6. Offline Software for the Mu2e Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Kutschke, Robert K. [Fermilab

    2012-01-01

    The Mu2e experiment at Fermilab is in the midst of its R&D and approval processes. To aid and inform this process, a small team has developed an end-to-end Geant4-based simulation package and has developed reconstruction code that is already at the stage of an advanced prototype. Having these tools available at an early stage allows design options and tradeoffs to be studied using high level physics quantities. A key to the success of this effort has been, as much as possible, to acquire software and customize it, rather than to build it in-house.

  7. Characteristic of bio-geometric profile of students’ posture and physical fitness in process of physical education

    Directory of Open Access Journals (Sweden)

    M.V. Dudko

    2015-08-01

    Full Text Available Purpose: to determine specific features of bio-geometric profile of posture and physical fitness of students in process of physical education. Material: 250 students were tested. Video-recording and analysis of bio-geometric profile of human posture were fulfilled. Program Torso was used for this purpose. Results: it was found out that only 15.2% of students had correct posture. The most quantity of posture abnormalities was detected in 36.4% of the tested. In sagittal plane we observed the following types of abnormalities: round back - in 24.4% of students, slouching back - in 24% of students. We found that 63.3% of students with normal posture are in zone of risk. Low backbone flexibility, mobility of hip joints and elasticity of hamstrings was detected on students. Conclusions: students with unsatisfactory bio-geometric profile of posture (scoliosis posture - 43.33%; round back - 23. 33%; slouching back - 22. 73% are in the called pre-morbid state of muscular-skeletal apparatus.

  8. Logistics Response to the Industry 4.0: the Physical Internet

    Science.gov (United States)

    Maslarić, Marinko; Nikoličić, Svetlana; Mirčetić, Dejan

    2016-11-01

    Today's mankind and all human activities are constantly changing and evolving in response to changes in technology, social and economic environments and climate. Those changes drive a "new" way of manufacturing industry. That novelty could be described as the organization of production processes based on technology and devices autonomously communicating with each other along the value chain. Decision-makers have to address this novelty (usually named as Industry 4.0) and try to develop appropriate information systems, physical facilities, and different kind of technologies capable of meeting the future needs of economy. As a consequence, there is a need for new paradigms of the way freight is move, store, realize, and supply through the world (logistics system). One of the proposed solutions is the Physical Internet, concept of open global logistics system which completely redefines current supply chain configuration, business models, and value-creation patterns.However, further detailed research on this topic is much needed. This paper aims to provide a balanced review of the variety of views considered among professionals in the field of Physical Internet with the final aim to identify the biggest challenges (technological, societal, business paradigm) of proposed new logistics paradigm as a practical solution in supporting Industry 4.0.

  9. Adaptive track scheduling to optimize concurrency and vectorization in GeantV

    International Nuclear Information System (INIS)

    Apostolakis, J; Brun, R; Carminati, F; Gheata, A; Novak, M; Wenzel, S; Bandieramonte, M; Bitzes, G; Canal, P; Elvira, V D; Jun, S Y; Lima, G; Licht, J C De Fine; Duhem, L; Sehgal, R; Shadura, O

    2015-01-01

    The GeantV project is focused on the R and D of new particle transport techniques to maximize parallelism on multiple levels, profiting from the use of both SIMD instructions and co-processors for the CPU-intensive calculations specific to this type of applications. In our approach, vectors of tracks belonging to multiple events and matching different locality criteria must be gathered and dispatched to algorithms having vector signatures. While the transport propagates tracks and changes their individual states, data locality becomes harder to maintain. The scheduling policy has to be changed to maintain efficient vectors while keeping an optimal level of concurrency. The model has complex dynamics requiring tuning the thresholds to switch between the normal regime and special modes, i.e. prioritizing events to allow flushing memory, adding new events in the transport pipeline to boost locality, dynamically adjusting the particle vector size or switching between vector to single track mode when vectorization causes only overhead. This work requires a comprehensive study for optimizing these parameters to make the behaviour of the scheduler self-adapting, presenting here its initial results. (paper)

  10. Study on light output and energy resolution of PbWO4 crystal

    International Nuclear Information System (INIS)

    Su Guanghui; Yue Ke; Sun Zhiyu

    2010-01-01

    The light output and energy resolution of PbWO 4 crystal are studied with different wrapping materials and methods. The Wrapping condition was optimized by analyzing the experimental data to gain higher light output and better energy resolution. A GEANT4-based package has been developed to simulate the corresponding features of PbWO 4 crystal, and the simulation results are consistent with the experimental data. (authors)

  11. Workshop on Processing Physic-Chemistry Advanced – WPPCA

    International Nuclear Information System (INIS)

    2016-01-01

    In the present volume of Journal of Physics: Conference Series we publish the proceedings of the “2nd Workshop on Processing Physic-Chemistry advanced (WPPCA)”, that was held from, April 4-8, 2016, at the Universidad Industrial de Santander (UIS), Bucaramanga, Colombia. The proceedings consist of 17 contributions that were presented as plenary talks at the event. The abstracts of all participants contributions were published in the Abstract Book with ISSN 2500-8420. The scientific program of the 2nd WPPCA consisted of 12 Magisterial Conferences, 28 Poster Presentations and 2 Courses with the participation of undergraduate and graduate students, professors, researchers and entrepreneurs from Colombia, Spain, Unite States of America, Mexico and Chile. Moreover, the 2nd WPPCA allowed to establish a shared culture of the research and innovation that enriches the area of the processing physical-chemistry of the materials and the industrial applications. All papers in these Proceedings refer to one from the following topics: Semiconductors, Superconductivity, Nanostructure Materials and Modelling, Simulation and Diagnostics. The editor hopes that those interested in the area of the science of materials can to enjoy this reading, that reflects a wide variety of current issues. On behalf of the organizing committee of the 2nd WPPCA, we are extremely thankful to all authors for providing their valuable contributions for these Proceedings as well as the reviewers for their constructive recommendations and criticism aiding to improve the presented articles. Besides, especially we appreciate the great support provided by the Sponsors and Partners. (paper)

  12. Particle tracking in sophisticated CAD models for simulation purposes

    International Nuclear Information System (INIS)

    Sulkimo, J.; Vuoskoski, J.

    1995-01-01

    The transfer of physics detector models from computer aided design systems to physics simulation packages like GEANT suffers from certain limitations. In addition, GEANT is not able to perform particle tracking in CAD models. We describe an application which is able to perform particle tracking in boundary models constructed in CAD systems. The transfer file format used is the new international standard, STEP. The design and implementation of the application was carried out using object-oriented techniques. It will be integrated in the future object-oriented version of GEANT. (orig.)

  13. Particle tracking in sophisticated CAD models for simulation purposes

    Science.gov (United States)

    Sulkimo, J.; Vuoskoski, J.

    1996-02-01

    The transfer of physics detector models from computer aided design systems to physics simulation packages like GEANT suffers from certain limitations. In addition, GEANT is not able to perform particle tracking in CAD models. We describe an application which is able to perform particle tracking in boundary models constructed in CAD systems. The transfer file format used is the new international standard, STEP. The design and implementation of the application was carried out using object-oriented techniques. It will be integrated in the future object-oriented version of GEANT.

  14. Development of a randomized 3D cell model for Monte Carlo microdosimetry simulations

    Energy Technology Data Exchange (ETDEWEB)

    Douglass, Michael; Bezak, Eva; Penfold, Scott [School of Chemistry and Physics, University of Adelaide, North Terrace, Adelaide 5005, South Australia (Australia) and Department of Medical Physics, Royal Adelaide Hospital, North Terrace, Adelaide 5000, South Australia (Australia)

    2012-06-15

    Purpose: The objective of the current work was to develop an algorithm for growing a macroscopic tumor volume from individual randomized quasi-realistic cells. The major physical and chemical components of the cell need to be modeled. It is intended to import the tumor volume into GEANT4 (and potentially other Monte Carlo packages) to simulate ionization events within the cell regions. Methods: A MATLAB Copyright-Sign code was developed to produce a tumor coordinate system consisting of individual ellipsoidal cells randomized in their spatial coordinates, sizes, and rotations. An eigenvalue method using a mathematical equation to represent individual cells was used to detect overlapping cells. GEANT4 code was then developed to import the coordinate system into GEANT4 and populate it with individual cells of varying sizes and composed of the membrane, cytoplasm, reticulum, nucleus, and nucleolus. Each region is composed of chemically realistic materials. Results: The in-house developed MATLAB Copyright-Sign code was able to grow semi-realistic cell distributions ({approx}2 Multiplication-Sign 10{sup 8} cells in 1 cm{sup 3}) in under 36 h. The cell distribution can be used in any number of Monte Carlo particle tracking toolkits including GEANT4, which has been demonstrated in this work. Conclusions: Using the cell distribution and GEANT4, the authors were able to simulate ionization events in the individual cell components resulting from 80 keV gamma radiation (the code is applicable to other particles and a wide range of energies). This virtual microdosimetry tool will allow for a more complete picture of cell damage to be developed.

  15. Adaptive, maladaptive, mediational, and bidirectional processes of relational and physical aggression, relational and physical victimization, and peer liking.

    Science.gov (United States)

    Kawabata, Yoshito; Tseng, Wan-Ling; Crick, Nicki R

    2014-01-01

    A three-wave longitudinal study among ethnically diverse preadolescents (N = 597 at Time 1, ages 9-11) was conducted to examine adaptive, maladaptive, mediational, and bidirectional processes of relational and physical aggression, victimization, and peer liking indexed by peer acceptance and friendships. A series of nested structural equation models tested the hypothesized links among these peer-domain factors. It was hypothesized that (1) relational aggression trails both adaptive and maladaptive processes, linking to more peer victimization and more peer liking, whereas physical aggression is maladaptive, resulting in more peer victimization and less peer liking; (2) physical and relational victimization is maladaptive, relating to more aggression and less peer liking; (3) peer liking may be the social context that promotes relational aggression (not physical aggression), whereas peer liking may protect against peer victimization, regardless of its type; and (4) peer liking mediates the link between forms of aggression and forms of peer victimization. Results showed that higher levels of peer liking predicted relative increases in relational aggression (not physical aggression), which in turn led to more peer liking. On the other hand, more peer liking was predictive of relative decreases in relational aggression and relational victimization in transition to the next grade (i.e., fifth grade). In addition, relational victimization predicted relative increases in relational aggression and relative decreases in peer liking. Similarly, physical aggression was consistently and concurrently associated more physical victimization and was marginally predictive of relative increases in physical victimization in transition to the next grade. More peer liking predicted relative decreases in physical victimization, which resulted in lower levels of peer liking. The directionality and magnitude of these paths did not differ between boys and girls. © 2013 Wiley

  16. Benchmarking of Monte Carlo simulation of bremsstrahlung from thick targets at radiotherapy energies

    International Nuclear Information System (INIS)

    Faddegon, Bruce A.; Asai, Makoto; Perl, Joseph; Ross, Carl; Sempau, Josep; Tinslay, Jane; Salvat, Francesc

    2008-01-01

    Several Monte Carlo systems were benchmarked against published measurements of bremsstrahlung yield from thick targets for 10-30 MV beams. The quantity measured was photon fluence at 1 m per unit energy per incident electron (spectra), and total photon fluence, integrated over energy, per incident electron (photon yield). Results were reported at 10-30 MV on the beam axis for Al and Pb targets and at 15 MV at angles out to 90 degree sign for Be, Al, and Pb targets. Beam energy was revised with improved accuracy of 0.5% using an improved energy calibration of the accelerator. Recently released versions of the Monte Carlo systems EGSNRC, GEANT4, and PENELOPE were benchmarked against the published measurements using the revised beam energies. Monte Carlo simulation was capable of calculation of photon yield in the experimental geometry to 5% out to 30 degree sign , 10% at wider angles, and photon spectra to 10% at intermediate photon energies, 15% at lower energies. Accuracy of measured photon yield from 0 to 30 degree sign was 5%, 1 s.d., increasing to 7% for the larger angles. EGSNRC and PENELOPE results were within 2 s.d. of the measured photon yield at all beam energies and angles, GEANT4 within 3 s.d. Photon yield at nonzero angles for angles covering conventional field sizes used in radiotherapy (out to 10 degree sign ), measured with an accuracy of 3%, was calculated within 1 s.d. of measurement for EGSNRC, 2 s.d. for PENELOPE and GEANT4. Calculated spectra closely matched measurement at photon energies over 5 MeV. Photon spectra near 5 MeV were underestimated by as much as 10% by all three codes. The photon spectra below 2-3 MeV for the Be and Al targets and small angles were overestimated by up to 15% when using EGSNRC and PENELOPE, 20% with GEANT4. EGSNRC results with the NIST option for the bremsstrahlung cross section were preferred over the alternative cross section available in EGSNRC and over EGS4. GEANT4 results calculated with the ''low energy

  17. Benchmarking of Monte Carlo simulation of bremsstrahlung from thick targets at radiotherapy energies

    Energy Technology Data Exchange (ETDEWEB)

    Faddegon, Bruce A.; Asai, Makoto; Perl, Joseph; Ross, Carl; Sempau, Josep; Tinslay, Jane; Salvat, Francesc [Department of Radiation Oncology, University of California at San Francisco, San Francisco, California 94143 (United States); Stanford Linear Accelerator Center, 2575 Sand Hill Road, Menlo Park, California 94025 (United States); National Research Council Canada, Institute for National Measurement Standards, 1200 Montreal Road, Building M-36, Ottawa, Ontario K1A 0R6 (Canada); Institut de Tecniques Energetiques, Universitat Politecnica de Catalunya and Centro de Investigacion Biomedica en Red en Bioingenieria, Biomateriales y Nanomedicina (CIBER-BBN), Diagonal 647, 08028 Barcelona (Spain); Stanford Linear Accelerator Center, 2575 Sand Hill Road, Menlo Park, California 94025 (United States); Facultat de Fisica (ECM), Universitat de Barcelona, Societat Catalana de Fisica (IEC), Diagonal 647, 08028 Barcelona (Spain)

    2008-10-15

    Several Monte Carlo systems were benchmarked against published measurements of bremsstrahlung yield from thick targets for 10-30 MV beams. The quantity measured was photon fluence at 1 m per unit energy per incident electron (spectra), and total photon fluence, integrated over energy, per incident electron (photon yield). Results were reported at 10-30 MV on the beam axis for Al and Pb targets and at 15 MV at angles out to 90 degree sign for Be, Al, and Pb targets. Beam energy was revised with improved accuracy of 0.5% using an improved energy calibration of the accelerator. Recently released versions of the Monte Carlo systems EGSNRC, GEANT4, and PENELOPE were benchmarked against the published measurements using the revised beam energies. Monte Carlo simulation was capable of calculation of photon yield in the experimental geometry to 5% out to 30 degree sign , 10% at wider angles, and photon spectra to 10% at intermediate photon energies, 15% at lower energies. Accuracy of measured photon yield from 0 to 30 degree sign was 5%, 1 s.d., increasing to 7% for the larger angles. EGSNRC and PENELOPE results were within 2 s.d. of the measured photon yield at all beam energies and angles, GEANT4 within 3 s.d. Photon yield at nonzero angles for angles covering conventional field sizes used in radiotherapy (out to 10 degree sign ), measured with an accuracy of 3%, was calculated within 1 s.d. of measurement for EGSNRC, 2 s.d. for PENELOPE and GEANT4. Calculated spectra closely matched measurement at photon energies over 5 MeV. Photon spectra near 5 MeV were underestimated by as much as 10% by all three codes. The photon spectra below 2-3 MeV for the Be and Al targets and small angles were overestimated by up to 15% when using EGSNRC and PENELOPE, 20% with GEANT4. EGSNRC results with the NIST option for the bremsstrahlung cross section were preferred over the alternative cross section available in EGSNRC and over EGS4. GEANT4 results calculated with the &apos

  18. PHYSICAL RESOURCES OF INFORMATION PROCESSES AND TECHNOLOGIES

    Directory of Open Access Journals (Sweden)

    Mikhail O. Kolbanev

    2014-11-01

    Full Text Available Subject of study. The paper describes basic information technologies for automating of information processes of data storage, distribution and processing in terms of required physical resources. It is shown that the study of these processes with such traditional objectives of modern computer science, as the ability to transfer knowledge, degree of automation, information security, coding, reliability, and others, is not enough. The reasons are: on the one hand, the increase in the volume and intensity of information exchange in the subject of human activity and, on the other hand, drawing near to the limit of information systems efficiency based on semiconductor technologies. Creation of such technologies, which not only provide support for information interaction, but also consume a rational amount of physical resources, has become an actual problem of modern engineering development. Thus, basic information technologies for storage, distribution and processing of information to support the interaction between people are the object of study, and physical temporal, spatial and energy resources required for implementation of these technologies are the subject of study. Approaches. An attempt is made to enlarge the possibilities of traditional cybernetics methodology, which replaces the consideration of material information component by states search for information objects. It is done by taking explicitly into account the amount of physical resources required for changes in the states of information media. Purpose of study. The paper deals with working out of a common approach to the comparison and subsequent selection of basic information technologies for storage, distribution and processing of data, taking into account not only the requirements for the quality of information exchange in particular subject area and the degree of technology application, but also the amounts of consumed physical resources. Main findings. Classification of resources

  19. Relaxation processes and physical aging in metallic glasses

    Science.gov (United States)

    Ruta, B.; Pineda, E.; Evenson, Z.

    2017-12-01

    Since their discovery in the 1960s, metallic glasses have continuously attracted much interest across the physics and materials science communities. In the forefront are their unique properties, which hold the alluring promise of broad application in fields as diverse as medicine, environmental science and engineering. However, a major obstacle to their wide-spread commercial use is their inherent temporal instability arising from underlying relaxation processes that can dramatically alter their physical properties. The result is a physical aging process which can bring about degradation of mechanical properties, namely through embrittlement and catastrophic mechanical failure. Understanding and controlling the effects of aging will play a decisive role in our on-going endeavor to advance the use of metallic glasses as structural materials, as well as in the more general comprehension of out-of-equilibrium dynamics in complex systems. This review presents an overview of the current state of the art in the experimental advances probing physical aging and relaxation processes in metallic glasses. Similarities and differences between other hard and soft matter glasses are highlighted. The topic is discussed in a multiscale approach, first presenting the key features obtained in macroscopic studies, then connecting them to recent novel microscopic investigations. Particular emphasis is put on the occurrence of distinct relaxation processes beyond the main structural process in viscous metallic melts and their fate upon entering the glassy state, trying to disentangle results and formalisms employed by the different groups of the glass-science community. A microscopic viewpoint is presented, in which physical aging manifests itself in irreversible atomic-scale processes such as avalanches and intermittent dynamics, ascribed to the existence of a plethora of metastable glassy states across a complex energy landscape. Future experimental challenges and the comparison with

  20. Parallel computation

    International Nuclear Information System (INIS)

    Jejcic, A.; Maillard, J.; Maurel, G.; Silva, J.; Wolff-Bacha, F.

    1997-01-01

    The work in the field of parallel processing has developed as research activities using several numerical Monte Carlo simulations related to basic or applied current problems of nuclear and particle physics. For the applications utilizing the GEANT code development or improvement works were done on parts simulating low energy physical phenomena like radiation, transport and interaction. The problem of actinide burning by means of accelerators was approached using a simulation with the GEANT code. A program of neutron tracking in the range of low energies up to the thermal region has been developed. It is coupled to the GEANT code and permits in a single pass the simulation of a hybrid reactor core receiving a proton burst. Other works in this field refers to simulations for nuclear medicine applications like, for instance, development of biological probes, evaluation and characterization of the gamma cameras (collimators, crystal thickness) as well as the method for dosimetric calculations. Particularly, these calculations are suited for a geometrical parallelization approach especially adapted to parallel machines of the TN310 type. Other works mentioned in the same field refer to simulation of the electron channelling in crystals and simulation of the beam-beam interaction effect in colliders. The GEANT code was also used to simulate the operation of germanium detectors designed for natural and artificial radioactivity monitoring of environment

  1. Physical processes in the Indian seas

    Digital Repository Service at National Institute of Oceanography (India)

    Swamy, G.N.; Das, V.K.; Antony, M.K.

    The proceedings volume comprise 38 papers covering air-sea boundary problems, open-ocean dynamics, nearshore processes, observational and analysis techniques, etc. This volume helps in taking stock of physical oceanographic activities in India...

  2. Preparation of physics commissioning of Mochovce units 3 and 4

    International Nuclear Information System (INIS)

    Sedlacek, M.; Chrapciak, V.

    2010-01-01

    The Project 'Mochovce Units 3 and 4 Completion' started in 2009 and it will be finished in 2013. VUJE, Inc. is one of the five main Project contractors for the Nuclear Island and it is responsible, inter alia, for Mochovce Units 3 and 4 commissioning. The commissioning of Units 3 and 4 includes the stages of Physics Commissioning and Power Commissioning. This paper deals with the preparation of Mochovce Units 3 and 4 Physics Commissioning. In the paper there is presented a preparation of some commissioning documents, e.g. 'Quality Assurance Programme', 'Commissioning Programme', 'Stage Programme for Physics Commissioning', 'Test working programmes', 'Neutron-physics characteristics for Physics and Power Commissioning', etc. The scope of Physics Commissioning is presented by list of tests. For assessment of tests results so-called three-level acceptance criteria will be applied: realization, design and safety criteria. In the paper there are also presented computer codes, which will be used for neutron-physics characteristics calculation and the fuel loading scheme for the reactor core of Mochovce Unit 3. (Authors)

  3. Initial performance studies of a general-purpose detector for multi-TeV physics at a 100 TeV pp collider

    Energy Technology Data Exchange (ETDEWEB)

    Chekanov, S. V.; Beydler, M.; Kotwal, A. V.; Gray, L.; Sen, S.; Tran, N. V.; Yu, S. -S.; Zuzelski, J.

    2017-06-01

    This paper describes simulations of detector response to multi-TeV physics at the Future Circular Collider (FCC-hh) or Super proton-proton Collider (SppC) which aim to collide proton beams with a centre-of-mass energy of 100 TeV. The unprecedented energy regime of these future experiments imposes new requirements on detector technologies which can be studied using the detailed GEANT4 simulations presented in this paper. The initial performance of a detector designed for physics studies at the FCC-hh or SppC experiments is described with an emphasis on measurements of single particles up to 33 TeV in transverse momentum. The reconstruction of hadronic jets has also been studied in the transverse momentum range from 50 GeV to 26 TeV. The granularity requirements for calorimetry are investigated using the two-particle spatial resolution achieved for hadron showers.

  4. Physical processes in hot cosmic plasmas

    International Nuclear Information System (INIS)

    Fabian, A.G.; Giovannelli, F.

    1990-01-01

    The interpretation of many high energy astrophysical phenomena relies on a detailed knowledge of radiation and transport processes in hot plasmas. The understanding of these plasma properties is one of the aims of terrestrial plasma physics. While the microscopic properties of astrophysical plasmas can hardly be determined experimentally, laboratory plasmas are more easily accessible to experimental techniques, but transient phenomena and the interaction of the plasma with boundaries often make the interpretation of measurements cumbersome. This book contains the talks given at the NATO Advanced Research Workshop on astro- and plasma-physics in Vulcano, Sicily, May 29-June 2, 1989. The book focuses on three main areas: radiation transport processes in hot (astrophysical and laboratory) plasmas; magnetic fields; their generation, reconnection and their effects on plasma transport properties; relativistic and ultra-high density plasmas

  5. Physics as Information Processing

    International Nuclear Information System (INIS)

    D'Ariano, Giacomo Mauro

    2011-01-01

    I review some recent advances in foundational research at Pavia QUIT group. The general idea is that there is only Quantum Theory without quantization rules, and the whole Physics - including space-time and relativity - is emergent from the quantum-information processing. And since Quantum Theory itself is axiomatized solely on informational principles, the whole Physics must be reformulated in information-theoretical terms: this is the It from bit of J. A. Wheeler.The review is divided into four parts: a) the informational axiomatization of Quantum Theory; b) how space-time and relativistic covariance emerge from quantum computation; c) what is the information-theoretical meaning of inertial mass and of (ℎ/2π), and how the quantum field emerges; d) an observational consequence of the new quantum field theory: a mass-dependent refraction index of vacuum. I will conclude with the research lines that will follow in the immediate future.

  6. Impact of detector simulation in particle physics collider experiments

    Science.gov (United States)

    Daniel Elvira, V.

    2017-06-01

    Through the last three decades, accurate simulation of the interactions of particles with matter and modeling of detector geometries has proven to be of critical importance to the success of the international high-energy physics (HEP) experimental programs. For example, the detailed detector modeling and accurate physics of the Geant4-based simulation software of the CMS and ATLAS particle physics experiments at the European Center of Nuclear Research (CERN) Large Hadron Collider (LHC) was a determinant factor for these collaborations to deliver physics results of outstanding quality faster than any hadron collider experiment ever before. This review article highlights the impact of detector simulation on particle physics collider experiments. It presents numerous examples of the use of simulation, from detector design and optimization, through software and computing development and testing, to cases where the use of simulation samples made a difference in the precision of the physics results and publication turnaround, from data-taking to submission. It also presents estimates of the cost and economic impact of simulation in the CMS experiment. Future experiments will collect orders of magnitude more data with increasingly complex detectors, taxing heavily the performance of simulation and reconstruction software. Consequently, exploring solutions to speed up simulation and reconstruction software to satisfy the growing demand of computing resources in a time of flat budgets is a matter that deserves immediate attention. The article ends with a short discussion on the potential solutions that are being considered, based on leveraging core count growth in multicore machines, using new generation coprocessors, and re-engineering HEP code for concurrency and parallel computing.

  7. 1st International Conference on Machine Learning for Cyber Physical Systems and Industry 4.0

    CERN Document Server

    Beyerer, Jürgen

    2016-01-01

    The work presents new approaches to Machine Learning for Cyber Physical Systems, experiences and visions. It contains some selected papers from the international Conference ML4CPS – Machine Learning for Cyber Physical Systems, which was held in Lemgo, October 1-2, 2015. Cyber Physical Systems are characterized by their ability to adapt and to learn: They analyze their environment and, based on observations, they learn patterns, correlations and predictive models. Typical applications are condition monitoring, predictive maintenance, image processing and diagnosis. Machine Learning is the key technology for these developments.

  8. Soil Heat Flow. Physical Processes in Terrestrial and Aquatic Ecosystems, Transport Processes.

    Science.gov (United States)

    Simpson, James R.

    These materials were designed to be used by life science students for instruction in the application of physical theory to ecosystem operation. Most modules contain computer programs which are built around a particular application of a physical process. Soil heat flow and the resulting soil temperature distributions have ecological consequences…

  9. Physics students' approaches to learning and cognitive processes in solving physics problems

    Science.gov (United States)

    Bouchard, Josee

    This study examined traditional instruction and problem-based learning (PBL) approaches to teaching and the extent to which they foster the development of desirable cognitive processes, including metacognition, critical thinking, physical intuition, and problem solving among undergraduate physics students. The study also examined students' approaches to learning and their perceived role as physics students. The research took place in the context of advanced courses of electromagnetism at a Canadian research university. The cognitive science, expertise, physics and science education, instructional psychology, and discourse processes literature provided the framework and background to conceptualize and structure this study. A within-stage mixed-model design was used and a number of instruments, including a survey, observation grids, and problem sets were developed specifically for this study. A special one-week long problem-based learning (PBL) intervention was also designed. Interviews with the instructors participating in the study provided complementary data. Findings include evidence that students in general engage in metacognitive processes in the organization of their personal study time. However, this potential, including the development of other cognitive processes, might not be stimulated as much as it could in the traditional lecture instructional context. The PBL approach was deemed as more empowering for the students. An unexpected finding came from the realisation that a simple exposure to a structured exercise of problem-solving (pre-test) was sufficient to produce superior planning and solving strategies on a second exposure (post-test) even for the students who had not been exposed to any special treatment. Maturation was ruled out as a potential threat to the validity of this finding. Another promising finding appears to be that the problem-based learning (PBL) intervention tends to foster the development of cognitive competencies, particularly

  10. Physical and mathematical modelling of extrusion processes

    DEFF Research Database (Denmark)

    Arentoft, Mogens; Gronostajski, Z.; Niechajowics, A.

    2000-01-01

    The main objective of the work is to study the extrusion process using physical modelling and to compare the findings of the study with finite element predictions. The possibilities and advantages of the simultaneous application of both of these methods for the analysis of metal forming processes...

  11. ERP differences between processing of physical characteristics and personality attributes

    Science.gov (United States)

    2012-01-01

    Background Limited data from behavioral and brain-imaging studies indicate that personality traits and physical characteristics are processed differently by the brain. Additionally, electrophysiological results of studies comparing the processing of positive and negative words have produced mixed results. It is therefore not clear how physical and personality attributes with emotional valence (i.e., positive and negative valence) are processed. Thus, this study aimed to examine the neural activity associated with words describing personality traits and physical characteristics with positive or negative emotional valence using Event Related Potentials (ERPs). Methods A sample of 15 healthy adults (7 men, 8 women) participated in a computerized word categorization task. Participants were asked to categorize visual word stimuli as physical characteristics or personality traits, while ERPs were recorded synchronously. Results Behavioral reaction times to negative physical stimuli were shorter compared to negative personality words, however reaction times did not significantly differ for positive stimuli. Electrophysiological results showed that personality stimuli elicited larger P2 and LPC (Late Positive Component) amplitudes compared to physical stimuli, regardless of negative or positive valence. Moreover, negative as compared with positive stimuli elicited larger P2 and LPC amplitudes. Conclusion Personality and physical stimuli were processed differently regardless of positive or negative valence. These findings suggest that personality traits and physical characteristics are differentially classified and are associated with different motivational significance. PMID:22967478

  12. Nuclear Transparency with the gamma + n -> pi- + p Process in 4He

    International Nuclear Information System (INIS)

    Dipangkar Dutta; Feng Xiong; Lingyan Zhu; John Arrington; Todd Averett; Elizabeth Beise; John Calarco; Ting Chang; Jian-Ping Chen; Eugene Chudakov; Marius Coman; Benjamin Clasie; Christopher Crawford; Sonja Dieterich; Frank Dohrmann; Kevin Fissum; Salvatore Frullani; Haiyan Gao; Ronald Gilman; Charles Glashausser; Javier Gomez; Kawtar Hafidi; Jens-Ole Hansen; Douglas Higinbotham; Holt, R.J.; Cornelis De Jager; Xiaochao Zheng; Jiang, X.; Edward Kinney; Kevin Kramer; Gerfried Kumbartzki; John LeRose; Nilanga Liyanage; David Mack; Pete Markowitz; Kathy McCormick; Zein-Eddine Meziani; Robert Michaels; Mitchell, J.; Sirish Nanda; David Potterveld; Ronald Ransome; Paul Reimer; Bodo Reitz; Arunava Saha; Elaine Schulte; Charles Seely; Simon Sirca; Steffen Strauch; Vincent Sulkosky; Branislav Vlahovic; Lawrence Weinstein; Krishni Wijesooriya; Claude Williamson; Bogdan Wojtsekhowski; Hong XIANG; Wang Xu; Zeng, J.

    2003-01-01

    We have measured the nuclear transparency of the fundamental process γ n → π - p in 4 He. These measurements were performed at Jefferson Lab in the photon energy range of 1.6 to 4.5 GeV and at θ cm π = 70 o and 90 o . These measurements are the first of their kind in the study of nuclear transparency in photoreactions. They also provide a benchmark test of Glauber calculations based on traditional models of nuclear physics. The transparency results suggest deviations from the traditional nuclear physics picture. The momentum transfer dependence of the measured nuclear transparency is consistent with Glauber calculations which include the quantum chromodynamics phenomenon of color transparency

  13. Influence of chromatin condensation on the number of direct DSB damages induced by ions studied using a Monte Carlo code

    International Nuclear Information System (INIS)

    Dos Santos, M.; Clairand, I.; Gruel, G.; Barquinero, J.F.; Villagrasa, C.; Incerti, S.

    2014-01-01

    The purpose of this work is to evaluate the influence of the chromatin condensation on the number of direct double-strand break (DSB) damages induced by ions. Two geometries of chromosome territories containing either condensed or de-condensed chromatin were implemented as biological targets in the Geant4 Monte Carlo simulation code and proton and alpha irradiation was simulated using the Geant4-DNA processes. A DBSCAN algorithm was used in order to detect energy deposition clusters that could give rise to single-strand breaks or DSBs on the DNA molecule. The results of this study show an increase in the number and complexity of DNA DSBs in condensed chromatin when compared with de-condensed chromatin. This work aims to evaluate the influence of the chromatin condensation in the number and complexity of direct DSB damages induced by proton and alpha irradiation. With the simulations of this study, the increase in the number and complexity of DSB-like clusters induced by ions in the heterochromatin when compared with euchromatin regions of the cell nucleus has been observed and quantified. These results suggest that condensed chromatin can be the location of more severe radiation-induced lesions, more difficult to repair, than de-condensed chromatin. On the other hand, it was also observed that, whatever the chromatin condensation, more possible damages are found after proton irradiation compared with alpha particles of the same LET. Nevertheless, as already remarked, this study concerns only the direct effect of ionising radiation that can be calculated from the results of the physical stage simulated with Geant4-DNA. To include indirect effects induced by radicals around the DNA molecule, the elements needed for simulating the chemical stage are being developed in the frame of the Geant4-DNA project(15, 16) and they are planned to be included in future work. With a complete calculation (direct + indirect damages) it would then be possible to estimate an energy

  14. Electrical Storm Simulation to Improve the Learning Physics Process

    Science.gov (United States)

    Martínez Muñoz, Miriam; Jiménez Rodríguez, María Lourdes; Gutiérrez de Mesa, José Antonio

    2013-01-01

    This work is part of a research project whose main objective is to understand the impact that the use of Information and Communication Technology (ICT) has on the teaching and learning process on the subject of Physics. We will show that, with the use of a storm simulator, physics students improve their learning process on one hand they understand…

  15. Description of charging/discharging processes of the LISA sensors

    International Nuclear Information System (INIS)

    Sumner, Tim; Araujo, Henrique; Davidge, David; Howard, Alex; Lee, Chris; Rochester, Geoff; Shaul, Diana; Wass, Peter

    2004-01-01

    The next generation of gravitational experiments in space is likely to use completely isolated proof-masses. For example, LISA uses proof-masses as mirrors in interferometers for gravitational wave astronomy (Bender et al 1998 Pre-phase A report MPG-233 pp 1-191) and STEP uses proof-masses in Earth orbit for an equivalence principle test (Sumner et al 2003 at press). Nongravitational forces will act on these proof-masses if they become charged, through the action of cosmic rays and solar flare particles for example. This paper examines the consequences of proof-mass charging for LISA, and presents results from using GEANT4 to assess the charging processes. Finally, there is a brief discussion of a means of controlling the charge down to an acceptable level

  16. The Application of SNiPER to the JUNO Simulation

    Science.gov (United States)

    Lin, Tao; Zou, Jiaheng; Li, Weidong; Deng, Ziyan; Fang, Xiao; Cao, Guofu; Huang, Xingtao; You, Zhengyun; JUNO Collaboration

    2017-10-01

    The JUNO (Jiangmen Underground Neutrino Observatory) is a multipurpose neutrino experiment which is designed to determine neutrino mass hierarchy and precisely measure oscillation parameters. As one of the important systems, the JUNO offline software is being developed using the SNiPER software. In this proceeding, we focus on the requirements of JUNO simulation and present the working solution based on the SNiPER. The JUNO simulation framework is in charge of managing event data, detector geometries and materials, physics processes, simulation truth information etc. It glues physics generator, detector simulation and electronics simulation modules together to achieve a full simulation chain. In the implementation of the framework, many attractive characteristics of the SNiPER have been used, such as dynamic loading, flexible flow control, multiple event management and Python binding. Furthermore, additional efforts have been made to make both detector and electronics simulation flexible enough to accommodate and optimize different detector designs. For the Geant4-based detector simulation, each sub-detector component is implemented as a SNiPER tool which is a dynamically loadable and configurable plugin. So it is possible to select the detector configuration at runtime. The framework provides the event loop to drive the detector simulation and interacts with the Geant4 which is implemented as a passive service. All levels of user actions are wrapped into different customizable tools, so that user functions can be easily extended by just adding new tools. The electronics simulation has been implemented by following an event driven scheme. The SNiPER task component is used to simulate data processing steps in the electronics modules. The electronics and trigger are synchronized by triggered events containing possible physics signals. The JUNO simulation software has been released and is being used by the JUNO collaboration to do detector design optimization, event

  17. Physics Colloquium: The optical route to quantum information processing

    CERN Multimedia

    Université de Genève

    2011-01-01

    Geneva University Physics Department 24, Quai Ernest Ansermet CH-1211 Geneva 4 Monday 11 April 2011 17h00 - Ecole de Physique, Auditoire Stückelberg The optical route to quantum information processing Prof. Terry Rudolph/Imperial College, London Photons are attractive as carriers of quantum information both because they travel, and can thus transmit information, but also because of their good coherence properties and ease in undergoing single-qubit manipulations. The main obstacle to their use in information processing is inducing an effective interaction between them in order to produce entanglement. The most promising approach in photon-based information processing architectures is so-called measurement-based quantum computing. This relies on creating upfront a multi-qubit highly entangled state (the cluster state) which has the remarkable property that, once prepared, it can be used to perform quantum computation by making only single qubit measurements. In this talk I will discuss generically the...

  18. Minimal-post-processing 320-Gbps true random bit generation using physical white chaos.

    Science.gov (United States)

    Wang, Anbang; Wang, Longsheng; Li, Pu; Wang, Yuncai

    2017-02-20

    Chaotic external-cavity semiconductor laser (ECL) is a promising entropy source for generation of high-speed physical random bits or digital keys. The rate and randomness is unfortunately limited by laser relaxation oscillation and external-cavity resonance, and is usually improved by complicated post processing. Here, we propose using a physical broadband white chaos generated by optical heterodyning of two ECLs as entropy source to construct high-speed random bit generation (RBG) with minimal post processing. The optical heterodyne chaos not only has a white spectrum without signature of relaxation oscillation and external-cavity resonance but also has a symmetric amplitude distribution. Thus, after quantization with a multi-bit analog-digital-convertor (ADC), random bits can be obtained by extracting several least significant bits (LSBs) without any other processing. In experiments, a white chaos with a 3-dB bandwidth of 16.7 GHz is generated. Its entropy rate is estimated as 16 Gbps by single-bit quantization which means a spectrum efficiency of 96%. With quantization using an 8-bit ADC, 320-Gbps physical RBG is achieved by directly extracting 4 LSBs at 80-GHz sampling rate.

  19. Habitual physical activity levels are positively correlated with CD4 ...

    African Journals Online (AJOL)

    Habitual physical activity levels are positively correlated with CD4 counts in an ... per month) and functional independence as assessed from the responses to the ... and between CD4 cell counts and total habitual physical activity levels (p ...

  20. Development of Monte Carlo input code for proton, alpha and heavy ion microdosimetric trac structure simulations

    International Nuclear Information System (INIS)

    Douglass, M.; Bezak, E.

    2010-01-01

    Full text: Radiobiology science is important for cancer treatment as it improves our understanding of radiation induced cell death. Monte Carlo simulations playa crucial role in developing improved knowledge of cellular processes. By model Ii ng the cell response to radiation damage and verifying with experimental data, understanding of cell death through direct radiation hits and bystander effects can be obtained. A Monte Carlo input code was developed using 'Geant4' to simulate cellular level radiation interactions. A physics list which enables physically accurate interactions of heavy ions to energies below 100 e V was implemented. A simple biological cell model was also implemented. Each cell consists of three concentric spheres representing the nucleus, cytoplasm and the membrane. This will enable all critical cell death channels to be investigated (i.e. membrane damage, nucleus/DNA). The current simulation has the ability to predict the positions of ionization events within the individual cell components on I micron scale. We have developed a Geant4 simulation for investigation of radiation damage to cells on sub-cellular scale (∼I micron). This code currently allows the positions of the ionisation events within the individual components of the cell enabling a more complete picture of cell death to be developed. The next stage will include expansion of the code to utilise non-regular cell lattice. (author)

  1. Radiotherapy Based On α Emitting Radionuclides: Geant4 For Dosimetry And Micro-/Nano-Dosimetry

    International Nuclear Information System (INIS)

    Guatelli, Susanna

    2013-01-01

    Possible physics approaches to evaluate the efficacy of TAT are dosimetry, microdosimetry and nanodosimetry. Dosimetry is adequate when mean absorbed dose to a macroscopic target volume is important to understand the biological effect of radiation. General purpose Monte Carlo (MC) codes, based on condensed history approach, are a very useful, cost effective tool to solve dosimetric problems. The condensed history approach is based on the use of multiple scattering theories to calculate the energy losses and angular changes in the direction of the particle. The short α particle range and high LET make the microdosimetric approach more suitable than dosimetry to study TAT from first physics principles, as this approach takes into account the stochastic nature of energy deposition at cellular level

  2. Physical activity (PA) and the disablement process

    DEFF Research Database (Denmark)

    Schultz-Larsen, Kirsten; Rahmanfard, Naghmeh; Holst, Claus

    2012-01-01

    . Among older women, the association between RPA and incidence of disability was attenuated in analyses that controlled for baseline mobility function. Thus, the association between physical activity and mortality reflected processes different from those underlying a simple relation between physical...... activity, disability and mortality. Physical activity was an ubiquitous predictor of longevity, but only for women....... community-living persons, aged 75-83 years, we evaluated the 1021 who reported no disability in basic activities of daily living. Participants were followed for a median of 8.34 years in public registers to determine onset of disability and mortality. RPA predicted mortality in older women (HR=1.77, 95%CI=1...

  3. The new ATLAS Fast Calorimeter Simulation

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00223142; The ATLAS collaboration

    2016-01-01

    Many physics and performance studies with the ATLAS detector at the Large Hadron Collider require very large samples of simulated events, and producing these using the full GEANT4 detector simulation is highly CPU intensive. Often, a very detailed detector simulation is not needed, and in these cases fast simulation tools can be used to reduce the calorimeter simulation time by a few orders of magnitude. The new ATLAS Fast Calorimeter Simulation (FastCaloSim) is an improved parametrisation compared to the one used in the LHC Run-1. It provides a simulation of the particle energy response at the calorimeter read-out cell level, taking into account the detailed particle shower shapes and the correlations between the energy depositions in the various calorimeter layers. It is interfaced to the standard ATLAS digitization and reconstruction software, and can be tuned to data more easily than with GEANT4. The new FastCaloSim incorporates developments in geometry and physics lists of the last five years and benefit...

  4. Physical and chemical characterization of bioaerosols - Implications for nucleation processes

    Science.gov (United States)

    Ariya, P. A.; Sun, J.; Eltouny, N. A.; Hudson, E. D.; Hayes, C. T.; Kos, G.

    The importance of organic compounds in the oxidative capacity of the atmosphere, and as cloud condensation and ice-forming nuclei, has been recognized for several decades. Organic compounds comprise a significant fraction of the suspended matter mass, leading to local (e.g. toxicity, health hazards) and global (e.g. climate change) impacts. The state of knowledge of the physical chemistry of organic aerosols has increased during the last few decades. However, due to their complex chemistry and the multifaceted processes in which they are involved, the importance of organic aerosols, particularly bioaerosols, in driving physical and chemical atmospheric processes is still very uncertain and poorly understood. Factors such as solubility, surface tension, chemical impurities, volatility, morphology, contact angle, deliquescence, wettability, and the oxidation process are pivotal in the understanding of the activation processes of cloud droplets, and their chemical structures, solubilities and even the molecular configuration of the microbial outer membrane, all impact ice and cloud nucleation processes in the atmosphere. The aim of this review paper is to assess the current state of knowledge regarding chemical and physical characterization of bioaerosols with a focus on those properties important in nucleation processes. We herein discuss the potential importance (or lack thereof) of physical and chemical properties of bioaerosols and illustrate how the knowledge of these properties can be employed to study nucleation processes using a modeling exercise. We also outline a list of major uncertainties due to a lack of understanding of the processes involved or lack of available data. We will also discuss key issues of atmospheric significance deserving future physical chemistry research in the fields of bioaerosol characterization and microphysics, as well as bioaerosol modeling. These fundamental questions are to be addressed prior to any definite conclusions on the

  5. Designing quantum information processing via structural physical approximation.

    Science.gov (United States)

    Bae, Joonwoo

    2017-10-01

    In quantum information processing it may be possible to have efficient computation and secure communication beyond the limitations of classical systems. In a fundamental point of view, however, evolution of quantum systems by the laws of quantum mechanics is more restrictive than classical systems, identified to a specific form of dynamics, that is, unitary transformations and, consequently, positive and completely positive maps to subsystems. This also characterizes classes of disallowed transformations on quantum systems, among which positive but not completely maps are of particular interest as they characterize entangled states, a general resource in quantum information processing. Structural physical approximation offers a systematic way of approximating those non-physical maps, positive but not completely positive maps, with quantum channels. Since it has been proposed as a method of detecting entangled states, it has stimulated fundamental problems on classifications of positive maps and the structure of Hermitian operators and quantum states, as well as on quantum measurement such as quantum design in quantum information theory. It has developed efficient and feasible methods of directly detecting entangled states in practice, for which proof-of-principle experimental demonstrations have also been performed with photonic qubit states. Here, we present a comprehensive review on quantum information processing with structural physical approximations and the related progress. The review mainly focuses on properties of structural physical approximations and their applications toward practical information applications.

  6. Radiation 2006. In association with the Polymer Division, Royal Australian Chemical Institute. Incorporating the 21st AINSE Radiation Chemistry Conference and the 18th Radiation Biology Conference, conference handbook

    International Nuclear Information System (INIS)

    Cornelius, I; Wroe, A.; Kwan, I.; Painuly, N.; Perera, L.; Lerch, M.; Takacs, G.; Rosenfeld, A.; Siegbahn, E.; Reinhard, M.; Marchetto, F.; Cirio, R.; Prokopovich, D.

    2006-01-01

    Full text: The Centre for Medical Radiation Physics (CMRP) and it's collaborative partners are actively involved with the development of semiconductor detectors and dosimeters for radiation protection, radiation oncology, and nuclear medicine applications. The GEANT4 Monte Carlo toolkit is used extensively in our current research projects. This poster will give an overview of our experience with the toolkit, including: the use of GEANT4 to calculate the dose distribution of HDR brachytherapy sources for comparison with TLD, ionisation chamber, and MOSFET measurements; the simulation of silicon microdosimetry measurements of an isotopic neutron source; the simulation of MOSFET dosimetry of synchrotron microbeams to understand lateral dose enhancement effects (see figure); estimating the effectiveness of various space shielding configurations using microdosimetry based calculations of biological dose; simulating small animal PET scanners using GATE; and the macroscopic verification of light ion fragmentation models via comparison with experimental data for energies and targets relevant to carbon ion therapy. Figures: Simulation of the response of an 'edge-on' MOSFET to a synchrotron microbeam. Dose profile obtained using GEANT4 and PENELOPE the lateral dose enhancement from the silicon substrate of the MOSFET is illustrated by the skewness of the dose profile

  7. PYTHIA 6.4 Physics and Manual

    Energy Technology Data Exchange (ETDEWEB)

    Sjostrand, Torbjorn; /Lund U., Dept. Theor. Phys.; Mrenna, Stephen; Skands, Peter; /Fermilab

    2006-03-01

    The Pythia program can be used to generate high-energy-physics ''events'', i.e. sets of outgoing particles produced in the interactions between two incoming particles. The objective is to provide as accurate as possible a representation of event properties in a wide range of reactions, within and beyond the Standard Model, with emphasis on those where strong interactions play a role, directly or indirectly, and therefore multihadronic final states are produced. The physics is then not understood well enough to give an exact description; instead the program has to be based on a combination of analytical results and various QCD-based models. This physics input is summarized here, for areas such as hard subprocesses, initial- and final-state parton showers, underlying events and beam remnants, fragmentation and decays, and much more. Furthermore, extensive information is provided on all program elements: subroutines and functions, switches and parameters, and particle and process data. This should allow the user to tailor the generation task to the topics of interest.

  8. Tests of Micro-Pattern Gaseous Detectors for active target time projection chambers in nuclear physics

    Energy Technology Data Exchange (ETDEWEB)

    Pancin, J., E-mail: pancin@ganil.fr [GANIL, CEA/DSM-CNRS/IN2P3, Bvd H. Becquerel, Caen (France); Damoy, S.; Perez Loureiro, D. [GANIL, CEA/DSM-CNRS/IN2P3, Bvd H. Becquerel, Caen (France); Chambert, V.; Dorangeville, F. [IPNO, CNRS/IN2P3, Orsay (France); Druillole, F. [CEA, DSM/Irfu/SEDI, Gif-Sur-Yvette (France); Grinyer, G.F. [GANIL, CEA/DSM-CNRS/IN2P3, Bvd H. Becquerel, Caen (France); Lermitage, A.; Maroni, A.; Noël, G. [IPNO, CNRS/IN2P3, Orsay (France); Porte, C.; Roger, T. [GANIL, CEA/DSM-CNRS/IN2P3, Bvd H. Becquerel, Caen (France); Rosier, P. [IPNO, CNRS/IN2P3, Orsay (France); Suen, L. [GANIL, CEA/DSM-CNRS/IN2P3, Bvd H. Becquerel, Caen (France)

    2014-01-21

    Active target detection systems, where the gas used as the detection medium is also a target for nuclear reactions, have been used for a wide variety of nuclear physics applications since the eighties. Improvements in Micro-Pattern Gaseous Detectors (MPGDs) and in micro-electronics achieved in the last decade permit the development of a new generation of active targets with higher granularity pad planes that allow spatial and time information to be determined with unprecedented accuracy. A novel active target and time projection chamber (ACTAR TPC), that will be used to study reactions and decays of exotic nuclei at facilities such as SPIRAL2, is presently under development and will be based on MPGD technology. Several MPGDs (Micromegas and Thick GEM) coupled to a 2×2 mm{sup 2} pixelated pad plane have been tested and their performances have been determined with different gases over a wide range of pressures. Of particular interest for nuclear physics experiments are the angular and energy resolutions. The angular resolution has been determined to be better than 1° FWHM for short traces of about 4 cm in length and the energy resolution deduced from the particle range was found to be better than 5% for 5.5 MeV α particles. These performances have been compared to Geant4 simulations. These experimental results validate the use of these detectors for several applications in nuclear physics.

  9. Tests of Micro-Pattern Gaseous Detectors for active target time projection chambers in nuclear physics

    International Nuclear Information System (INIS)

    Pancin, J.; Damoy, S.; Perez Loureiro, D.; Chambert, V.; Dorangeville, F.; Druillole, F.; Grinyer, G.F.; Lermitage, A.; Maroni, A.; Noël, G.; Porte, C.; Roger, T.; Rosier, P.; Suen, L.

    2014-01-01

    Active target detection systems, where the gas used as the detection medium is also a target for nuclear reactions, have been used for a wide variety of nuclear physics applications since the eighties. Improvements in Micro-Pattern Gaseous Detectors (MPGDs) and in micro-electronics achieved in the last decade permit the development of a new generation of active targets with higher granularity pad planes that allow spatial and time information to be determined with unprecedented accuracy. A novel active target and time projection chamber (ACTAR TPC), that will be used to study reactions and decays of exotic nuclei at facilities such as SPIRAL2, is presently under development and will be based on MPGD technology. Several MPGDs (Micromegas and Thick GEM) coupled to a 2×2 mm 2 pixelated pad plane have been tested and their performances have been determined with different gases over a wide range of pressures. Of particular interest for nuclear physics experiments are the angular and energy resolutions. The angular resolution has been determined to be better than 1° FWHM for short traces of about 4 cm in length and the energy resolution deduced from the particle range was found to be better than 5% for 5.5 MeV α particles. These performances have been compared to Geant4 simulations. These experimental results validate the use of these detectors for several applications in nuclear physics

  10. IGUANA Architecture, Framework and Toolkit for Interactive Graphics

    CERN Document Server

    Alverson, G; Muzaffar, S; Osborne, I; Tuura, L A; Taylor, L; Alverson, George; Eulisse, Giulio; Muzaffar, Shahzad; Osborne, Ianna; Tuura, Lassi A.; Taylor, Lucas

    2003-01-01

    IGUANA is a generic interactive visualisation framework based on a C++ component model. It provides powerful user interface and visualisation primitives in a way that is not tied to any particular physics experiment or detector design. The article describes interactive visualisation tools built using IGUANA for the CMS and D0 experiments, as well as generic GEANT4 and GEANT3 applications. It covers features of the graphical user interfaces, 3D and 2D graphics, high-quality vector graphics output for print media, various textual, tabular and hierarchical data views, and integration with the application through control panels, a command line and different multi-threading models.

  11. GUANA Architecture, Framework and Toolkit for Interactive Graphics

    CERN Document Server

    Alverson, G; Muzaffar, S; Osborne, I; Tuura, L A; Taylor, L

    2003-01-01

    IGUANA is a generic interactive visualisation framework based on a C++ component model. It provides powerful user interface and visualisation primitives in a way that is not tied to any particular physics experiment or detector design. The article describes interactive visualisation tools built using IGUANA for the CMS and D0 experiments, as well as generic GEANT4 and GEANT3 applications. It covers features of the graphical user interfaces, 3D and 2D graphics, high-quality vector graphics output for print media, various textual, tabular and hierarchical data views, and integration with the application through control panels, a command line and different multi-threading models.

  12. SU-C-BRC-06: OpenCL-Based Cross-Platform Monte Carlo Simulation Package for Carbon Ion Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Qin, N; Tian, Z; Pompos, A; Jiang, S; Jia, X [UT Southwestern Medical Ctr, Dallas, TX (United States); Pinto, M; Dedes, G; Parodi, K [Ludwig-Maximilians-Universitaet Muenchen, Garching / Munich (Germany)

    2016-06-15

    Purpose: Monte Carlo (MC) simulation is considered to be the most accurate method for calculation of absorbed dose and fundamental physical quantities related to biological effects in carbon ion therapy. Its long computation time impedes clinical and research applications. We have developed an MC package, goCMC, on parallel processing platforms, aiming at achieving accurate and efficient simulations for carbon therapy. Methods: goCMC was developed under OpenCL framework. It supported transport simulation in voxelized geometry with kinetic energy up to 450 MeV/u. Class II condensed history algorithm was employed for charged particle transport with stopping power computed via Bethe-Bloch equation. Secondary electrons were not transported with their energy locally deposited. Energy straggling and multiple scattering were modeled. Production of secondary charged particles from nuclear interactions was implemented based on cross section and yield data from Geant4. They were transported via the condensed history scheme. goCMC supported scoring various quantities of interest e.g. physical dose, particle fluence, spectrum, linear energy transfer, and positron emitting nuclei. Results: goCMC has been benchmarked against Geant4 with different phantoms and beam energies. For 100 MeV/u, 250 MeV/u and 400 MeV/u beams impinging to a water phantom, range difference was 0.03 mm, 0.20 mm and 0.53 mm, and mean dose difference was 0.47%, 0.72% and 0.79%, respectively. goCMC can run on various computing devices. Depending on the beam energy and voxel size, it took 20∼100 seconds to simulate 10{sup 7} carbons on an AMD Radeon GPU card. The corresponding CPU time for Geant4 with the same setup was 60∼100 hours. Conclusion: We have developed an OpenCL-based cross-platform carbon MC simulation package, goCMC. Its accuracy, efficiency and portability make goCMC attractive for research and clinical applications in carbon therapy.

  13. Roles of medical image processing in medical physics

    International Nuclear Information System (INIS)

    Arimura, Hidetaka

    2011-01-01

    Image processing techniques including pattern recognition techniques play important roles in high precision diagnosis and radiation therapy. The author reviews a symposium on medical image information, which was held in the 100th Memorial Annual Meeting of the Japan Society of Medical Physics from September 23rd to 25th. In this symposium, we had three invited speakers, Dr. Akinobu Shimizu, Dr. Hideaki Haneishi, and Dr. Hirohito Mekata, who are active engineering researchers of segmentation, image registration, and pattern recognition, respectively. In this paper, the author reviews the roles of the medical imaging processing in medical physics field, and the talks of the three invited speakers. (author)

  14. Consistency check of photon beam physical data after recommissioning process

    International Nuclear Information System (INIS)

    Kadman, B; Chawapun, N; Ua-apisitwong, S; Asakit, T; Chumpu, N; Rueansri, J

    2016-01-01

    In radiotherapy, medical linear accelerator (Linac) is the key system used for radiation treatments delivery. Although, recommissioning was recommended after major modification of the machine by AAPM TG53, but it might not be practical in radiotherapy center with heavy workloads. The main purpose of this study was to compare photon beam physical data between initial commissioning and recommissioning of 6 MV Elekta Precise linac. The parameters for comparing were the percentage depth dose (PDD) and beam profiles. The clinical commissioning test cases followed IAEA-TECDOC-1583 were planned on REF 91230 IMRT Dose Verification Phantom by Philips’ Pinnacle treatment planning system. The Delta 4PT was used for dose distribution verification with 90% passing criteria of the gamma index (3%/3mm). Our results revealed that the PDDs and beam profiles agreed within a tolerance limit recommended by TRS430. Most of the point doses and dose distribution verification passed the acceptance criteria. This study showed the consistency of photon beam physical data after recommissioning process. There was a good agreement between initial commissioning and recommissioning within a tolerance limit, demonstrated that the full recommissioning process might not be required. However, in the complex treatment planning geometry, the initial data should be applied with great caution. (paper)

  15. Synthesis, physical and chemical properties, antihypoxic activity of some 5-[((5-(adamantane-1-yl-4-R-4H-1,2,4-triazole-3-ylthiomethyl]-N-R1-1,3,4-thiadiazole-2-amines and 5-[((5-(adamantane-1-yl-4-R-4H-1,2,4-triazole-3-ylthiomethyl]-4-R1-4H-1,2,4-t

    Directory of Open Access Journals (Sweden)

    V. M. Odyntsova

    2018-03-01

    Full Text Available Today, an increase of natural and technogenic situations leads to the disorders of the central nervous system, functional-metabolic processes, vascular diseases, in particular, acute cerebral blood flow disorders. In addition, the changes occurring on the molecular and cellular levels are in the basis of the functional violations of individual systems and the organism as a whole. Hypoxia not only complicates the disease course, but in most cases, determines its outcome. The important role in the fight against hypoxia belongs to antioxidants, which improve the circulating oxygen utilization by the body, reduce its need for the organs and tissues, which is not only expedient but necessary for the treatment of many acute and chronic pathological processes. So, the frequency of the hypoxic states and a wide range of factors causing them determine the relevance of new ways and methods finding to overcome the oxygen deficiency. The aim of this work is the purposeful search of some 5-[((5-(adamantane-1-yl-4-R-4H-1,2,4-triazole-3-ylthiomethyl]-N-R1-1,3,4-thiadiazole-2-amines and 5-[((5-(adamantane-1-yl-4-R-4H-1,2,4-triazole-3-ylthiomethyl]-4-R1-4H-1,2,4-triazole-3-thiols, the study of their physical and chemical properties and pharmacological screening of the antihypoxic activity of the obtained compounds. Materials and methods. The study of physical and chemical properties was conducted on certified and licensed modern equipment. Antihypoxic activity was studied during the modeling process of hypoxia with hypercapnia. Mexidol was used as a comparison drug in studies at a dose of 100 mg/kg. Results. As the result of the study, it was found that the synthesized compounds and the comparison drug influenced on rats’ life span differently. Compounds, the antihypoxic activity of which exceeded control have been discovered, and others’ were at the level of Mexidol. A number of compounds showed a somewhat less activity in comparison with control, and two

  16. Contextualization processes and the initial education of physics teachers

    Directory of Open Access Journals (Sweden)

    Cristina Cândida de Macedo

    2014-03-01

    Full Text Available Contextualization of school contents has been seen as a possibility of facilitating students’ learning, since it makes the educative process more significant to them. However, there is no agreement as to the meaning and the forms of applying such processes. Particularly in the area of Science teaching, the creation of thematic projects has been seen as a way of contextualizing school contents. It is noteworthy that the experience with the education of Physics teachers shows that the creation and execution of such projects brings many difficulties to teachers, the main obstacle being the understanding of what contextualized educative processes are. Having this in mind, a project has been elaborated with the objective of analyzing the comprehension Physics teachers that are going through teacher education courses have of the processes of contextualization. The data for this investigation has been obtained from students who attended a course of the Physics Teacher Education module at the Federal University of Itajubá. It is significant to mention that in this course students are asked to create three versions of a thematic project. In order to analyze the data, the procedure of Thematic Content and Category Analysis was adopted. This research shows that Physics teachers to be incorporate the discourses of the educative ideas throughout the course. However, there is a series of obstacles they face as they attempt to understand and carry out contextualized educative processes. Those difficulties are connected to their experience with this kind of educative process throughout the years they spend at school and in the teacher education course. We conclude thus that it is essential that contextualized educative activities be part of the reality of teacher education programs.

  17. Space plasma physics stationary processes

    CERN Document Server

    Hasegawa, Akira

    1989-01-01

    During the 30 years of space exploration, important discoveries in the near-earth environment such as the Van Allen belts, the plasmapause, the magnetotail and the bow shock, to name a few, have been made. Coupling between the solar wind and the magnetosphere and energy transfer processes between them are being identified. Space physics is clearly approaching a new era, where the emphasis is being shifted from discoveries to understanding. One way of identifying the new direction may be found in the recent contribution of atmospheric science and oceanography to the development of fluid dynamics. Hydrodynamics is a branch of classical physics in which important discoveries have been made in the era of Rayleigh, Taylor, Kelvin and Helmholtz. However, recent progress in global measurements using man-made satellites and in large scale computer simulations carried out by scientists in the fields of atmospheric science and oceanography have created new activities in hydrodynamics and produced important new discover...

  18. DEVELOPMENT OF COORDINATION ABILITIES OF FUTURE TEACHERS OF PHYSICAL TRAINING IN THE TRAINING PROCESS

    Directory of Open Access Journals (Sweden)

    Aleksandr Nikolaevich Shutov

    2015-02-01

    Full Text Available The article presents the results of implementing the methods of development coordination abilities in students of different sports specializations, students at the Faculty of Physical Education in the process of training in gymnastics. In the content of the classes includes a range of applied exercises with rotation in different planes of space, as a support, and the unsupported position, as well as their implementation in different directions of motion.The purpose - to improve the methods of development of coordination abilities of future teachers of physical culture in the process of training.Methodology development of coordination abilities based on the use of compound exercises with rotation in different planes of the space in the support and unsupported posture.Results. As a result of the development of methods of coordination abilities of the students showed a significant gain significant results when performing jumps with rotation (p <0.05. Significant increase was seen in the results of the students involved in wrestling, the results of which have reached the indicators close to the values typical for students specializing in gymnastics.The average value of the expert evaluation of the motor action from the arsenal of acrobatics and exercises on the equipment the students of the experimental group was 4.7 and 4.6 points, while the traditional method for dealing with this figure is 3.4 and 3.1 point, respectively (p < 0.05.Practical implications. Technique can be used as part of training students of physical culture of pedagogical universities.

  19. Proceedings of the 4. International Symposium on Radiation Physics - Abstracts

    International Nuclear Information System (INIS)

    1988-01-01

    The studies on: fundamental processes in radiation physics; radiation sources and detectors; physical, chemical and biological radiation effects; plasma technology; radioisotope application in medicine and agriculture; environment; use of radiation in material science and; reactor technology, are presented. (M.C.K.) [pt

  20. Girdler-sulfide process physical properties

    International Nuclear Information System (INIS)

    Neuburg, H.J.; Atherley, J.F.; Walker, L.G.

    1977-05-01

    Physical properties of pure hydrogen sulfide and of gaseous and liquid solutions of the H 2 S-H 2 O system have been formulated. Tables for forty-nine different properties in the pressure and temperature range of interest to the Girdler-Sulfide (GS) process for heavy water production are given. All properties are presented in SI units. A computer program capable of calculating properties of the pure components as well as gaseous mixtures and liquid solutions at saturated and non-saturated conditions is included. (author)

  1. Dispersal from deep ocean sources: physical and related scientific processes

    International Nuclear Information System (INIS)

    Robinson, A.R.; Kupferman, S.L.

    1985-02-01

    This report presents the results of the workshop ''Dispersal from Deep Ocean Sources: Physical and Related Scientific Processes,'' together with subsequent developments and syntheses of the material discussed there. The project was undertaken to develop usable predictive descriptions of dispersal from deep oceanic sources. Relatively simple theoretical models embodying modern ocean physics were applied, and observational and experimental data bases were exploited. All known physical processes relevant to the dispersal of passive, conservative tracers were discussed, and contact points for inclusion of nonconservative processes (biological and chemical) were identified. Numerical estimates of the amplitude, space, and time scales of dispersion were made for various mechanisms that control the evolution of the dispersal as the material spreads from a bottom point source to small-, meso-, and world-ocean scales. Recommendations for additional work are given. The volume is presented as a handbook of dispersion processes. It is intended to be updated as new results become available

  2. [High energy particle physics]: Task A, High energy physics program: Experiment and theory; Task B, High energy physics program: Numerical simulation of quantum field theories

    International Nuclear Information System (INIS)

    Lannutti, J.E.

    1991-01-01

    This report discusses the following research: fixed target experiments; collider experiments; computing, networking and VAX upgrade; SSC preparation, detector development and detector construction; solid argon calorimetry; absorption of CAD system geometries into GEANT for SSC; and particle theory programs

  3. Design of the gas cell for the IGISOL facility at ELI-NP

    Energy Technology Data Exchange (ETDEWEB)

    Constantin, P., E-mail: paul.constantin@eli-np.ro [Extreme Light Infrastructure – Nuclear Physics, “Horia Hulubei” National Institute for Physics and Nuclear Engineering, Str. Reactorului 30, 077125 Bucharest Magurele (Romania); Balabanski, D.L. [Extreme Light Infrastructure – Nuclear Physics, “Horia Hulubei” National Institute for Physics and Nuclear Engineering, Str. Reactorului 30, 077125 Bucharest Magurele (Romania); Anh, L.T. [Extreme Light Infrastructure – Nuclear Physics, “Horia Hulubei” National Institute for Physics and Nuclear Engineering, Str. Reactorului 30, 077125 Bucharest Magurele (Romania); Graduate University of Science and Technology, Vietnam Academy of Science and Technology, Hanoi (Viet Nam); Cuong, P.V. [Extreme Light Infrastructure – Nuclear Physics, “Horia Hulubei” National Institute for Physics and Nuclear Engineering, Str. Reactorului 30, 077125 Bucharest Magurele (Romania); Centre of Nuclear Physics, Institute of Physics, Vietnam Academy of Science and Technology, Hanoi (Viet Nam); Mei, B. [Extreme Light Infrastructure – Nuclear Physics, “Horia Hulubei” National Institute for Physics and Nuclear Engineering, Str. Reactorului 30, 077125 Bucharest Magurele (Romania)

    2017-04-15

    One of the experimental programs that will be carried out at the Extreme Light Infrastructure – Nuclear Physics (ELI-NP) facility is the production of exotic neutron-rich ion beams in an IGISOL facility via photofission in a stack of actinide targets placed at the center of a cell filled with He gas. Simulations with the Geant4 toolkit were done for the optimization of the target configuration that maximizes the rate of released photofission fragments. The cell geometry is established based on the stopping properties of these fragments. Studies, based on simulations with Geant4 and SIMION 8.1, of the space charge effect and its induced electric field in the gas cell are presented. Estimates of the extraction time and efficiency of the photofission fragments are derived.

  4. Physics at a 100 TeV pp Collider: Standard Model Processes

    Energy Technology Data Exchange (ETDEWEB)

    Mangano, M. L. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Zanderighi, G. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Aguilar Saavedra, J. A. [Univ. of Granada (Spain); Alekhin, S. [Univ. of Hamburg (Germany). Inst. for Theoretical Physics; Inst. for High Energy Physics (IHEP), Moscow (Russian Federation); Badger, S. [Univ. of Edinburgh, Scotland (United Kingdom); Bauer, C. W. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Becher, T. [Univ. Bern (Switzerland); Bertone, V. [Univ. of Oxford (United Kingdom); Bonvini, M. [Univ. of Oxford (United Kingdom); Boselli, S. [Univ. of Pavia (Italy); Bothmann, E. [Gottingen Univ. (Germany); Boughezal, R. [Argonne National Lab. (ANL), Argonne, IL (United States); Cacciari, M. [Univ. Paris Diderot (France); Sorbonne Univ., Paris (France); Carloni Calame, C M. [Istituto Nazionale di Fisica Nucleare (INFN), Pavia (Italy); Caola, F. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Campbell, J. M. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Carrazza, S. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Chiesa, M. [Istituto Nazionale di Fisica Nucleare (INFN), Pavia (Italy); Cieri, L. [Univ. of Zurich (Switzerland); Cimaglia, F. [Univ. degli Studi di Milano (Italy); Febres Cordero, F. [Physikalisches Inst., Freiburg (Germany); Ferrarese, P. [Gottingen Univ. (Germany); D' Enterria, D. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Ferrera, G. [Univ. degli Studi di Milano (Italy); Garcia i Tormo, X. [Univ. Bern (Switzerland); Garzelli, M. V. [Univ. of Hamburg (Germany); Germann, E. [Monash Univ., Melbourne, VIC (Australia); Hirschi, V. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Han, T. [Univ. of Pittsburgh, PA (United States); Ita, H. [Physikalisches Inst., Freiburg (Germany); Jager, B. [Univ. of Tubingen (Germany); Kallweit, S. [Johannes Gutenberg Univ., Mainz (Germany); Karlberg, A. [Univ. of Oxford (United Kingdom); Kuttimalai, S. [Durham Univ. (United Kingdom); Krauss, F. [Durham Univ. (United Kingdom); Larkoski, A. J. [Harvard Univ., Cambridge, MA (United States); Lindert, J. [Univ. of Zurich (Switzerland); Luisoni, G. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Maierhofer, P. [Univ. of Freiburg (Germany); Mattelaer, O. [Durham Univ. (United Kingdom); Martinez, H. [Univ. of Pavia (Italy); Moch, S. [Univ. of Hamburg (Germany); Montagna, G. [Univ. of Pavia (Italy); Moretti, M. [Univ. of Ferrara (Italy); Nason, P. [Univ. of Milano (Italy); Nicrosini, O. [Istituto Nazionale di Fisica Nucleare (INFN), Pavia (Italy); Oleari, C. [Univ. of Milano (Italy); Pagani, D. [Univ. Catholique de Louvain (Belgium); Papaefstathiou, A. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Petriello, F. [Northwestern Univ., Evanston, IL (United States); Piccinini, F. [Istituto Nazionale di Fisica Nucleare (INFN), Pavia (Italy); Pierini, M. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Pierog, T. [Karlsruhe Inst. of Technology (KIT) (Germany); Pozzorini, S. [Univ. of Zurich (Switzerland); Re, E. [National Centre for Scientific Research (CNRS), Annecy-le-Vieux (France). Lab. of Annecy-le-Vieux for Theoretical Physics (LAPTh); Robens, T. [Technische Universitat Dresden (Germany); Rojo, J. [Univ. of Oxford (United Kingdom); Ruiz, R. [Durham Univ. (United Kingdom); Sakurai, K. [Durham Univ. (United Kingdom); Salam, G. P. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Salfelder, L. [Univ. of Tubingen (Germany); Schonherr, M. [Univ. of Ferrara (Italy); Schulze, M. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Schumann, S. [Univ. Gottingen (Germany); Selvaggi, M. [Univ. Catholique de Louvain (Belgium); Shivaji, A. [Istituto Nazionale di Fisica Nucleare (INFN), Pavia (Italy); Siodmok, A. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Polish Academy of Sciences (PAS), Krakow (Poland); Skands, P. [Monash Univ., Melbourne, VIC (Australia); Torrielli, P. [Univ. of Torino (Italy); Tramontano, F. [Univ. of Napoli (Italy); Tsinikos, I. [Univ. Catholique de Louvain (Belgium); Tweedie, B. [Univ. of Pittsburgh, PA (United States); Vicini, A. [Univ. degli Studi di Milano (Italy); Westhoff, S. [Heidelberg Univ. (Germany); Zaro, M. [Sorbonne Univ., Paris (France); Zeppenfeld, D. [Forschungszentrum Karlsruhe (Germany)

    2017-06-22

    This report summarises the properties of Standard Model processes at the 100 TeV pp collider. We document the production rates and typical distributions for a number of benchmark Standard Model processes, and discuss new dynamical phenomena arising at the highest energies available at this collider. We discuss the intrinsic physics interest in the measurement of these Standard Model processes, as well as their role as backgrounds for New Physics searches.

  5. Programs for low-energy nuclear physics data processing

    International Nuclear Information System (INIS)

    Antuf'ev, Yu.P.; Dejneko, A.S.; Ekhichev, O.I.; Kuz'menko, V.A.; Mashkarov, Yu.G.; Nemashkalo, B.A.; Skakun, E.A.; Storizhko, V.E.; Shlyakhov, N.A.

    1978-01-01

    Purpose of six computer programs developed in KhPTI of AN USSR for the processing of the experimental data on low energy nuclear physics ia friendly described. The programs are written in Algol-60 language. They are applied to some types of nuclear reactions and permit to process differential cross sections and γ spectra, to compute statistical tensors and excitation functions as well as to analyze some processes by means of theoretical models

  6. Bringing life to soil physical processes

    Science.gov (United States)

    Hallett, P. D.

    2013-12-01

    When Oklahoma's native prairie grass roots were replaced by corn, the greatest environmental (and social) disaster ever to hit America ensued. The soils lost structure, physical binding by roots was annihilated and when drought came the Great Dust Bowl commenced. This form of environmental disaster has repeated over history and although not always apparent, similar processes drive the degradation of seemingly productive farmland and forests. But just as negative impacts on biology are deleterious to soil physical properties, positive impacts could reverse these trends. In finding solutions to soil sustainability and food security, we should be able to exploit biological processes to improve soil physical properties. This talk will focus on a quantitative understanding of how biology changes soil physical behaviour. Like the Great Dust Bowl, it starts with reinforcement mechanisms by plant roots. We found that binding of soil by cereal (barley) roots within 5 weeks of planting can more than double soil shear strength, with greater plant density causing greater reinforcement. With time, however, the relative impact of root reinforcement diminishes due to root turnover and aging of the seedbed. From mechanical tests of individual roots, reasonable predictions of reinforcement by tree roots are possible with fibre bundle models. With herbaceous plants like cereals, however, the same parameters (root strength, stiffness, size and distribution) result in a poor prediction. We found that root type, root age and abiotic factors such as compaction and waterlogging affect mechanical behaviour, further complicating the understanding and prediction of root reinforcement. For soil physical stability, the interface between root and soil is an extremely important zone in terms of resistance of roots to pull-out and rhizosphere formation. Compounds analogous to root exudates have been found with rheological tests to initially decrease the shear stress where wet soils flow, but

  7. The Processes of Inclusion and Exclusion in Physical Education

    DEFF Research Database (Denmark)

    Jensen, Mette Munk; Agergaard, Sine

    2015-01-01

    Existing research on inclusion and exclusion processes in physical education (PE) has particularly focused on exclusion from PE as something being done to students and attributed to specific social categories such as (female) gender, (low) physical skills or (minority) ethnic background....... This article aims to develop a social-relational perspective on inclusion and exclusion processes defined as students’ participation or non-participation in PE interpreted as a community of practice. In so doing, the article examines how students’ experiences of participation and non-participation in PE...... or non-participation is important not only in terms of how we talk about students as passive victims or active agents, but also in terms of future intervention aimed at promoting inclusion processes in PE....

  8. Physical Abuse, Cognitive and Emotional Processes, and Aggressive/Disruptive Behavior Problems

    Science.gov (United States)

    Teisl, Michael; Cicchetti, Dante

    2008-01-01

    Cognitive and emotional processes were examined in maltreated children with a history of physical abuse (n = 76), children with a history of maltreatment other than physical abuse (i.e., sexual abuse, physical neglect, and emotional maltreatment; n = 91), and a group of non-maltreated comparison children (N = 100). Physical abuse was associated…

  9. CalcHEP 3.4 for collider physics within and beyond the Standard Model

    Science.gov (United States)

    Belyaev, Alexander; Christensen, Neil D.; Pukhov, Alexander

    2013-07-01

    We present version 3.4 of the CalcHEP software package which is designed for effective evaluation and simulation of high energy physics collider processes at parton level. The main features of CalcHEP are the computation of Feynman diagrams, integration over multi-particle phase space and event simulation at parton level. The principle attractive key-points along these lines are that it has: (a) an easy startup and usage even for those who are not familiar with CalcHEP and programming; (b) a friendly and convenient graphical user interface (GUI); (c) the option for the user to easily modify a model or introduce a new model by either using the graphical interface or by using an external package with the possibility of cross checking the results in different gauges; (d) a batch interface which allows to perform very complicated and tedious calculations connecting production and decay modes for processes with many particles in the final state. With this features set, CalcHEP can efficiently perform calculations with a high level of automation from a theory in the form of a Lagrangian down to phenomenology in the form of cross sections, parton level event simulation and various kinematical distributions. In this paper we report on the new features of CalcHEP 3.4 which improves the power of our package to be an effective tool for the study of modern collider phenomenology. Program summaryProgram title: CalcHEP Catalogue identifier: AEOV_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEOV_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 78535 No. of bytes in distributed program, including test data, etc.: 818061 Distribution format: tar.gz Programming language: C. Computer: PC, MAC, Unix Workstations. Operating system: Unix. RAM: Depends on process under study

  10. Bridging scales in polymer physics and processing

    NARCIS (Netherlands)

    Hütter, M.; Kröger, M.; Öttinger, H.C.; Schweizer, T.

    2001-01-01

    Understanding both the flow behavior of polymers during processing and the end-use properties offinished plastic products from a molecular picture of the constituent polymers has been a long-standing dreamin polymer engineering and science. It is the goal of our work in the Polymer Physics Group to

  11. Physical education resources, class management, and student physical activity levels: a structure-process-outcome approach to evaluating physical education effectiveness.

    Science.gov (United States)

    Bevans, Katherine B; Fitzpatrick, Leslie-Anne; Sanchez, Betty M; Riley, Anne W; Forrest, Christopher

    2010-12-01

    This study was conducted to empirically evaluate specific human, curricular, and material resources that maximize student opportunities for physical activity during physical education (PE) class time. A structure-process-outcome model was proposed to identify the resources that influence the frequency of PE and intensity of physical activity during PE. The proportion of class time devoted to management was evaluated as a potential mediator of the relations between resource availability and student activity levels. Data for this cross-sectional study were collected from interviews conducted with 46 physical educators and the systematic observation of 184 PE sessions in 34 schools. Regression analyses were conducted to test for the main effects of resource availability and the mediating role of class management. Students who attended schools with a low student-to-physical educator ratio had more PE time and engaged in higher levels of physical activity during class time. Access to adequate PE equipment and facilities was positively associated with student activity levels. The availability of a greater number of physical educators per student was found to impact student activity levels by reducing the amount of session time devoted to class management. The identification of structure and process predictors of student activity levels in PE will support the allocation of resources and encourage instructional practices that best support increased student activity levels in the most cost-effective way possible. Implications for PE policies and programs are discussed. © 2010, American School Health Association.

  12. Physics & Preservice Teachers Partnership Project (P4): An interdisciplinary peer learning tool

    Science.gov (United States)

    Simmonds, Paul J.; Wenner, Julianne A.

    Physics graduate students (PGs) and teacher candidates (TCs) often graduate with specific weaknesses. PGs frequently lack training in teaching and effective communication. TCs are typically underprepared for teaching science, and physics in particular. In response to these challenges, we created P4 . P4 is an innovative model for peer learning, creating interdisciplinary partnerships that help college physics instructors train their students in the ``soft skills'' prized in both academia and industry, while helping teacher educators infuse more content knowledge into science methods courses. In P4, PGs plan a lesson and deliver physics content to TCs. TCs then use this content to design and execute a 15-minute elementary science lesson. Framed by the concept of peer learning, we expected P4 would help PGs develop their teaching and communication skills, and TCs learn more physics. We studied the affordances and constraints of P4 to inform future iterations. Overall, P4 was successful, with both PGs and TCs reporting benefits. Affordances for PGs included the chance to plan and teach a class; TCs benefitted from working with experts to increase content knowledge. We will share the full findings and implications of our study, and outline next steps for P4.

  13. QCD jet simulation with CMS at LHC and background studies to H to gamma gamma process

    CERN Document Server

    Litvin, V; Shevchenko, S; Wisniewski, N

    2002-01-01

    We have simulated and reconstructed one million of QCD jet events. This study was done with CMS full detector simulation, based on GEANT3 package, and object-oriented CMS C++ reconstruction program. The understanding of QCD jet background is important for the Higgs search in two-photon decay mode. The comparison with other types of backgrounds was also done. It was shown that the isolation tools were important ones to isolate the signal process from the huge background one. Using the isolation criteria based on the information from PbWO /sub 4/ electromagnetic calorimeter and the tracker we were able to reduce the QCD jet background to 15% of the total one. (9 refs).

  14. Project Physics Tests 4, Light and Electromagnetism.

    Science.gov (United States)

    Harvard Univ., Cambridge, MA. Harvard Project Physics.

    Test items relating to Project Physics Unit 4 are presented in this booklet. Included are 70 multiple-choice and 22 problem-and-essay questions. Concepts of light and electromagnetism are examined on charges, reflection, electrostatic forces, electric potential, speed of light, electromagnetic waves and radiations, Oersted's and Faraday's work,…

  15. The application of the algorithm of the individualization of students’ physical education process

    Directory of Open Access Journals (Sweden)

    L.N. Barybina

    2014-12-01

    Full Text Available Purpose: theoretically and experimentally justify the use of the algorithm of physical education process individualization in universities taking into account the psychophysiological features of students. Material: the study involved 413 students. It was defined indicators of the level of physical fitness and functional status, psycho-physiological features. Results: it was worked out the algorithm of individualization of students’ physical education process. It was defined the structure of the complex preparedness and it was developed models of characteristics of students - representatives of different sports specializations. It was established that for the successful construction of the training process, it is necessary to combine the parameters of physical, functional training and physiological indicators into a single integral evaluation of the individual characteristics of students. It was shown that at the students of the experimental group was improved indicators of functional, psychophysiological capabilities and physical preparedness. Conclusions: the application of the algorithm of the individualization of process of physical education enhances the functionality of the students.

  16. Advanced statistics to improve the physical interpretation of atomization processes

    International Nuclear Information System (INIS)

    Panão, Miguel R.O.; Radu, Lucian

    2013-01-01

    Highlights: ► Finite pdf mixtures improves physical interpretation of sprays. ► Bayesian approach using MCMC algorithm is used to find the best finite mixture. ► Statistical method identifies multiple droplet clusters in a spray. ► Multiple drop clusters eventually associated with multiple atomization mechanisms. ► Spray described by drop size distribution and not only its moments. -- Abstract: This paper reports an analysis of the physics of atomization processes using advanced statistical tools. Namely, finite mixtures of probability density functions, which best fitting is found using a Bayesian approach based on a Markov chain Monte Carlo (MCMC) algorithm. This approach takes into account eventual multimodality and heterogeneities in drop size distributions. Therefore, it provides information about the complete probability density function of multimodal drop size distributions and allows the identification of subgroups in the heterogeneous data. This allows improving the physical interpretation of atomization processes. Moreover, it also overcomes the limitations induced by analyzing the spray droplets characteristics through moments alone, particularly, the hindering of different natures of droplet formation. Finally, the method is applied to physically interpret a case-study based on multijet atomization processes

  17. Processes and Instructions Encouraging Thai Students Consistently Pass the First Round of The National Physics Academics Olympiads

    Science.gov (United States)

    Teevasuthornsakul, Chalongchai; Manosuttirit, Artnarong; Suwanno, Chirasak; Sutsaguan, Lanchakorn

    2010-07-01

    This research focused on the processes and physics instruction of 25 schools located in Bangkok and up-country in Thailand in order to explain why many of their students have passed the first round of the National Physics Academic Olympiads consistently. The high schools in Thailand can apply and support their students and develop their potential in physics. The development of physics professional is the cornerstone of a developing country and increase physics quality base on sciences development in the future in Thailand. The duration of collecting all data was from May 2007 to May 2009. The methodology for this research was the qualitative research method. The researchers interviewed managers, teachers and students at each school location or used semi-structured interview forms. The researchers used the Investigator Triangulation approach to check the qualitative data and the Cause and Effect Analysis approach to analyze situation factors. The results showed that in processes were include 1) enhanced the students with the Academic Olympiads to develop the capacities of students; 2) motivated the students with processes such as good instruction in physics and special privilege in continuing studies in university; and 3) tutorial systems and drill and practice systems support students into subsequent rounds. 4) Admiration activities accommodated the students continually and suitably. Most of the teaching styles used in their lectures, in both basic contents and practice, encouraged students to analyze entrance examination papers, little laboratory. While students say that" They just know that a physics laboratory is very important to study physics after they passed Olympic camp."

  18. Workshop Physics Activity Guide, Module 4: Electricity and Magnetism

    Science.gov (United States)

    Laws, Priscilla W.

    2004-05-01

    The Workshop Physics Activity Guide is a set of student workbooks designed to serve as the foundation for a two-semester calculus-based introductory physics course. It consists of 28 units that interweave text materials with activities that include prediction, qualitative observation, explanation, equation derivation, mathematical modeling, quantitative experiments, and problem solving. Students use a powerful set of computer tools to record, display, and analyze data, as well as to develop mathematical models of physical phenomena. The design of many of the activities is based on the outcomes of physics education research. The Workshop Physics Activity Guide is supported by an Instructor's Website that: (1) describes the history and philosophy of the Workshop Physics Project; (2) provides advice on how to integrate the Guide into a variety of educational settings; (3) provides information on computer tools (hardware and software) and apparatus; and (4) includes suggested homework assignments for each unit. Log on to the Workshop Physics Project website at http://physics.dickinson.edu/ Workshop Physics is a component of the Physics Suite--a collection of materials created by a group of educational reformers known as the Activity Based Physics Group. The Physics Suite contains a broad array of curricular materials that are based on physics education research, including: Understanding Physics, by Cummings, Laws, Redish and Cooney (an introductory textbook based on the best-selling text by Halliday/Resnick/Walker) RealTime Physics Laboratory Modules Physics by Inquiry (intended for use in a workshop setting) Interactive Lecture Demonstration Tutorials in Introductory Physics Activity Based Tutorials (designed primarily for use in recitations)

  19. 12 CFR 510.4 - Service of process.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Service of process. 510.4 Section 510.4 Banks and Banking OFFICE OF THRIFT SUPERVISION, DEPARTMENT OF THE TREASURY MISCELLANEOUS ORGANIZATIONAL REGULATIONS § 510.4 Service of process. (a) Service of Process. Service of process may be made upon the Office...

  20. Synthesis and physical-chemical properties of 3-alkylthio-5-(quinoline-2-yl, 2-hydroxyquinoline-4-yl-4-R-2,4-dihydro-3H-1,2,4-triazoles

    Directory of Open Access Journals (Sweden)

    T. M. Kaplaushenko

    2016-06-01

    Full Text Available The major social and economic problem of pharmaceutical industry is the search for biologically active substances, which may become the basis of new drugs, competitive with expensive imported drugs. Analysis of literature shows that in recent decades the attention is paid to researches of heterocyclic systems as potential biologically active agents of both domestic and foreign scientists. Particular interest in this regard cause 3-thio derivatives of 1,2,4-triazoles. Despite high number of publications relating to synthesis and biological properties of 1,2,4-triazole derivatives, the structure and physical-chemical properties of these compounds are studied insufficiently. In this regard, the study of synthetic, physical-chemical and biological properties of 3-alkylthio-5-(quinoline-2-yl, 2-hydroxyquinoline-4-yl-4-R1-2,4-dihydro-3H-1,2,4-triazoles in our point of view is a new, theoretically and practically significant direction. Purpose - targeted synthesis of new low-toxic and highly effective compounds with potential pharmacological activity in a series of 3-alkylthio-5-(quinoline-2-yl, 2-hydroxyquinoline-4-yl-4-R-2,4-dihydro-3H-1,2,4-triazoles and the study of physical and chemical properties of the synthesized compounds. Materials and methods. As starting compounds 5-(quinoline-2-il- 2-hydroxyquinoline-4-yl-4-R1-3-thio-1,2,4-triazoles have been used. Through further cooperation with halogen alkanes (ethyl bromide, propyl bromide, amyl bromide, octyl bromide, nonyl bromide, decyl bromide, cyclohexyl chloride, benzyl chloride 3-alkylthio-5-(quinoline-2-yl, 2-hydroxyquinoline-4-yl-4-R1-2,4-dyhidro-3H-1,2,4-triazoles have been obtained. Results. 15 New compounds have been received as a result of synthetic transformations, the structure of synthesized compounds has been confirmed by modern complex of physical and chemical methods of analysis (IR-spectrophotometry, 1H NMR-spectroscopy, elemental analysis, and their individuality has been proved by