WorldWideScience

Sample records for geant4 electromagnetic physics

  1. Geant4 Low Energy Electromagnetic Physics

    Institute of Scientific and Technical Information of China (English)

    S.Chauvie; G.Depaola; 等

    2001-01-01

    Geant4 Low Energy Electromagnetic package Provides a precise treatment of electromagnetic interations of particles with matter down to very low energies (250 oV for electrons and photons,<1 keV for hadrons and ions),It includes a veriety of models for the electromagnetic processes of electrons,photons,hadrons and ions,taking into account advance features,such as shell effects and effects due to charge dependence.The comprehensive set of particle types it can handle,the variety of modeling approaches and the extended coverage of energy range make this package a unique tool among Monte Carlo codes on the market,and of relevance to serveral experimental domains in HIEP,astroparticle physics,space science and biomedical studies.

  2. Geant4 electromagnetic physics updates for space radiation effects simulation

    Science.gov (United States)

    Ivantchenko, Anton; Nieminen, Petteri; Incerti, Sebastien; Santin, Giovanni; Ivantchenko, Vladimir; Grichine, Vladimir; Allison, John; Karamitos, Mathiew

    The Geant4 toolkit is used in many applications including space science studies. The new Geant4 version 10.0 released in December 2013 includes a major revision of the toolkit and offers multi-threaded mode for event level parallelism. At the same time, Geant4 electromagnetic and hadronic physics sub-libraries have been significantly updated. In order to validate the new and updated models Geant4 verification tests and benchmarks were extended. Part of these developments was sponsored by the European Space Agency in the context of research aimed at modelling radiation biological end effects. In this work, we present an overview of results of several benchmarks for electromagnetic physics models relevant to space science. For electromagnetic physics, recently Compton scattering, photoelectric effect, and Rayleigh scattering models have been improved and extended down to lower energies. Models of ionization and fluctuations have also been improved; special micro-dosimetry models for Silicon and liquid water were introduced; the main multiple scattering model was consolidated; and the atomic de-excitation module has been made available to all models. As a result, Geant4 predictions for space radiation effects obtained with different Physics Lists are in better agreement with the benchmark data than previous Geant4 versions. Here we present results of electromagnetic tests and models comparison in the energy interval 10 eV - 10 MeV.

  3. Geant4 electromagnetic physics: improving simulation performance and accuracy

    Science.gov (United States)

    Ivanchenko, V. N.; Incerti, S.; Allison, J.; Bagulya, A.; Brown, J. M. C.; Champion, C.; Elles, S.; Francis, Z.; Grichine, V.; Ivantchenko, A.; Jacquemier, J.; Karamitros, M.; Maire, M.; Mantero, A.; Pandola, L.; Raine, M.; Reis, M. A.; Santin, G.; Sawkey, D.; Schaelicke, A.; Schenk, M.; Taborda, A.; Urban, L.; Yamashita, T.

    2014-06-01

    The most recent upgrades of the electromagnetic (EM) physics "standard" and "low energy" sub-libraries of the general purpose Geant4 Monte Carlo simulation toolkit are described. These upgrades are relevant to different application domains including high energy physics, medical physics and space science. Validation results are presented and discussed.

  4. Progress in Geant4 Electromagnetic Physics Modelling and Validation

    Science.gov (United States)

    Apostolakis, J.; Asai, M.; Bagulya, A.; Brown, J. M. C.; Burkhardt, H.; Chikuma, N.; Cortes-Giraldo, M. A.; Elles, S.; Grichine, V.; Guatelli, S.; Incerti, S.; Ivanchenko, V. N.; Jacquemier, J.; Kadri, O.; Maire, M.; Pandola, L.; Sawkey, D.; Toshito, T.; Urban, L.; Yamashita, T.

    2015-12-01

    In this work we report on recent improvements in the electromagnetic (EM) physics models of Geant4 and new validations of EM physics. Improvements have been made in models of the photoelectric effect, Compton scattering, gamma conversion to electron and muon pairs, fluctuations of energy loss, multiple scattering, synchrotron radiation, and high energy positron annihilation. The results of these developments are included in the new Geant4 version 10.1 and in patches to previous versions 9.6 and 10.0 that are planned to be used for production for run-2 at LHC. The Geant4 validation suite for EM physics has been extended and new validation results are shown in this work. In particular, the effect of gamma-nuclear interactions on EM shower shape at LHC energies is discussed.

  5. Progress in Geant4 Electromagnetic Physics Modelling and Validation

    CERN Document Server

    Apostolakis, J; Bagulya, A; Brown, J M C; Burkhardt, H; Chikuma, N; Cortes-Giraldo, M A; Elles, S; Grichine, V; Guatelli, S; Incerti, S; Ivanchenko, V N; Jacquemier, J; Kadri, O; Maire, M; Pandola, L; Sawkey, D; Toshito, T; Urban, L; Yamashita, T

    2015-01-01

    In this work we report on recent improvements in the electromagnetic (EM) physics models of Geant4 and new validations of EM physics. Improvements have been made in models of the photoelectric effect, Compton scattering, gamma conversion to electron and muon pairs, fluctuations of energy loss, multiple scattering, synchrotron radiation, and high energy positron annihilation. The results of these developments are included in the new Geant4 version 10.1 and in patches to previous versions 9.6 and 10.0 that are planned to be used for production for run-2 at LHC. The Geant4 validation suite for EM physics has been extended and new validation results are shown in this work. In particular, the effect of gamma-nuclear interactions on EM shower shape at LHC energies is discussed.

  6. Progress in Geant4 Electromagnetic Physics Modelling and Validation

    CERN Document Server

    Apostolakis, J; Bagulya, A; Brown, J M C; Burkhardt, H; Chikuma, N; Cortes-Giraldo, M A; Elles, S; Grichine, V; Guatelli, S; Incerti, S; Ivanchenko, V N; Jacquemier, J; Kadri, O; Maire, M; Pandola, L; Sawkey, D; Toshito, T; Urban, L; Yamashita, T

    2015-01-01

    In this work we report on recent improvements in the electromagnetic (EM) physics models of Geant4 and new validations of EM physics. Improvements have been made in models of the photoelectric effect, Compton scattering, gamma conversion to electron and muon pairs, fluctuations of energy loss, multiple scattering, synchrotron radiation, and high energy positron annihilation. The results of these developments are included in the new Geant4 version 10.1 and in patches to previous versions 9.6 and 10.0 that are planned to be used for production for run-2 at LHC. The Geant4 validation suite for EM physics has been extended and new validation results are shown in this work. In particular, the effect of gamma-nuclear interactions on EM shower shape at LHC energies is discussed.

  7. Research in Geant4 electromagnetic physics design, and its effects on computational performance and quality assurance

    CERN Document Server

    Augelli, M; Hauf, S; Kim, C H; Kuster, M; Pia, M G; Filho, P Queiroz; Quintieri, L; Saracco, P; Santos, D Souza; Weidenspointner, G; Zoglauer, A

    2009-01-01

    The Geant4 toolkit offers a rich variety of electromagnetic physics models; so far the evaluation of this Geant4 domain has been mostly focused on its physics functionality, while the features of its design and their impact on simulation accuracy, computational performance and facilities for verification and validation have not been the object of comparable attention yet, despite the critical role they play in many experimental applications. A new project is in progress to study the application of new design concepts and software techniques in Geant4 electromagnetic physics, and to evaluate how they can improve on the current simulation capabilities. The application of a policy-based class design is investigated as a means to achieve the objective of granular decomposition of processes; this design technique offers various advantages in terms of flexibility of configuration and computational performance. The current Geant4 physics models have been re-implemented according to the new design as a pilot project....

  8. Combination of electromagnetic physics processes for microdosimetry in liquid water with the Geant4 Monte Carlo simulation toolkit

    Energy Technology Data Exchange (ETDEWEB)

    Ivanchenko, V.N. [Ecoanalytica, 119899 Moscow (Russian Federation); Geant4 Associates International Ltd. (United Kingdom); Incerti, S., E-mail: incerti@cenbg.in2p3.fr [Universite Bordeaux 1, CNRS/IN2P3, Centre d' Etudes Nucleaires de Bordeaux Gradignan, CENBG, Chemin du Solarium, BP120, 33175 Gradignan (France); Francis, Z. [Universite Saint Joseph, Science Faculty, Department of Physics, Beirut (Lebanon); Tran, H.N.; Karamitros, M. [Universite Bordeaux 1, CNRS/IN2P3, Centre d' Etudes Nucleaires de Bordeaux Gradignan, CENBG, Chemin du Solarium, BP120, 33175 Gradignan (France); Bernal, M.A. [Instituto de Fisica Gleb Wataghin, Universidade Estadual de Campinas - UNICAMP, Campinas 13083-859 SP (Brazil); Champion, C. [Universite Bordeaux 1, CNRS/IN2P3, Centre d' Etudes Nucleaires de Bordeaux Gradignan, CENBG, Chemin du Solarium, BP120, 33175 Gradignan (France); Universite Paul Verlaine-Metz, Laboratoire de Physique Moleculaire et des Collisions, 1 Boulevard Arago, Technopole 2000, 57078 Metz (France); Gueye, P. [Hampton University, Physics Department, Hampton, VA 23668 (United States); Collaboration: Geant4-DNA Collaboration

    2012-02-15

    The Geant4 Monte Carlo simulation toolkit provides a set of electromagnetic physics processes adapted to the detailed simulation of particle interactions in liquid water for microdosimetry applications, such as single-cell irradiation with light ion beams. These processes, developed within the framework of the Geant4-DNA project, adopt a software design allowing their combination with other electromagnetic physics processes available in the Geant4 toolkit. This work describes the combination of Geant4-DNA electron processes with Geant4 photon processes.

  9. Geant4 electromagnetic physics for high statistic simulation of LHC experiments

    CERN Document Server

    Allison, J; Bagulya, A; Champion, C; Elles, S; Garay, F; Grichine, V; Howard, A; Incerti, S; Ivanchenko, V; Jacquemier, J; Maire, M; Mantero, A; Nieminen, P; Pandola, L; Santin, G; Sawkey, D; Schalicke, A; Urban, L

    2012-01-01

    An overview of the current status of electromagnetic physics (EM) of the Geant4 toolkit is presented. Recent improvements are focused on the performance of large scale production for LHC and on the precision of simulation results over a wide energy range. Significant efforts have been made to improve the accuracy without compromising of CPU speed for EM particle transport. New biasing options have been introduced, which are applicable to any EM process. These include algorithms to enhance and suppress processes, force interactions or splitting of secondary particles. It is shown that the performance of the EM sub-package is improved. We will report extensions of the testing suite allowing high statistics validation of EM physics. It includes validation of multiple scattering, bremsstrahlung and other models. Cross checks between standard and low-energy EM models have been performed using evaluated data libraries and reference benchmark results.

  10. Geant4 for the atlas electromagnetic calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Kordas, K.; Parrour, G. [Laboratoire de l' Accelerateur Lineaire, 91 - Orsay (France); Simion, St. [Columbia Univ., New York, NY (United States). Nevis Labs

    2001-04-01

    We have recently employed the Geant4 tool-kit for the simulation of the barrel part of the ATLAS electromagnetic calorimeter. The two approaches used for the description of this geometry are presented and compared. Subsequently, we test the new simulation tool against the predictions of Geant3, the previous generation of the Geant simulation. We do so for muons. With the caveat of some differences in the detector geometry implementations in Geant4 and Geant3, we also show some extremely preliminary results for electrons. A comparison between the two geometry models has shown that there are very small differences, which are under study, but in general the tailored geometry approach is proven sound. We also investigated a way to reduce significantly the memory usage of the straight-forward 'static' geometry description. Comparing Geant4 against Geant3, we find that the mean energy depositions for 50 and 100 GeV muons are in agreement between the two simulations, but the two yield significantly different distributions. Preliminary results on electrons are encouraging and we plan to study these particles next, including comparisons with test beam data. (authors)

  11. GEANT4 Physics Lists for HEP

    CERN Document Server

    Apostolakis, J; Grichine, V; Howard, A; Ivanchenko, V; Kosov, M; Ribon, A; Uzhinsky, V; Wright, D H

    2009-01-01

    In GEANT4, a Physics List is a consistent set of. physics models that is able to cover all combinations of incident particle type, energy, and target material. Various Physics Lists are possible and useful, according to the specific application domains (e.g. high-energy physics, shielding, space-application, medical physics, etc.), and the best compromise between accuracy and CPU time that the user can accept. Users are allowed to write their own preferred Physics List, but several pre-defined ones are available in GEANT4 for convenience, and indeed they are used by the large majority of users. We present here the Physics Lists that are of interest for high-energy physics applications.

  12. Energy deposition in small-scale targets of liquid water using the very low energy electromagnetic physics processes of the Geant4 toolkit

    Science.gov (United States)

    Incerti, S.; Champion, C.; Tran, H. N.; Karamitros, M.; Bernal, M.; Francis, Z.; Ivanchenko, V.; Mantero, A.; Members of Geant4-DNA Collaboration

    2013-07-01

    In the perspective of building an open source simulation platform dedicated to the modelling of early biological molecular damages due to ionising radiation at the DNA scale, the general-purpose Geant4 Monte Carlo simulation toolkit has been recently extended with specific very low energy electromagnetic physics processes for liquid water medium. These processes - also called “Geant4-DNA” processes - simulate the physical interactions induced by electrons, hydrogen and helium atoms of different charge states. The present work reports on the energy deposit distributions obtained for incident electrons, protons and alpha particles in nanometre-size volumes comparable to those present in the genetic material of mammalian cells. The frequency distributions of the energy deposition obtained for three typical geometries of nanometre-size cylindrical targets placed in a spherical phantom are found to be in reasonable agreement with prior works. Furthermore, we present a combination of the Geant4-DNA processes with a simplified geometrical model of a cellular nucleus allowing the evaluation of energy deposits in volumes of biological interest.

  13. Design and performance evaluations of generic programming techniques in a R&D prototype of Geant4 physics

    CERN Document Server

    Pia, M G; Sudhakar, M; Zoglauer, A; Augelli, M; Gargioni, E; Kim, C H; Quintieri, L; Filho, P P de Queiroz; Santos, D de Souza; Weidenspointner, G; Begalli, M

    2010-01-01

    A R&D project has been recently launched to investigate Geant4 architectural design in view of addressing new experimental issues in HEP and other related physics disciplines. In the context of this project the use of generic programming techniques besides the conventional object oriented is investigated. Software design features and preliminary results from a new prototype implementation of Geant4 electromagnetic physics are illustrated. Performance evaluations are presented. Issues related to quality assurance in Geant4 physics modelling are discussed.

  14. GPU in Physics Computation: Case Geant4 Navigation

    CERN Document Server

    Seiskari, Otto; Niemi, Tapio

    2012-01-01

    General purpose computing on graphic processing units (GPU) is a potential method of speeding up scientific computation with low cost and high energy efficiency. We experimented with the particle physics simulation toolkit Geant4 used at CERN to benchmark its geometry navigation functionality on a GPU. The goal was to find out whether Geant4 physics simulations could benefit from GPU acceleration and how difficult it is to modify Geant4 code to run in a GPU. We ported selected parts of Geant4 code to C99 & CUDA and implemented a simple gamma physics simulation utilizing this code to measure efficiency. The performance of the program was tested by running it on two different platforms: NVIDIA GeForce 470 GTX GPU and a 12-core AMD CPU system. Our conclusion was that GPUs can be a competitive alternate for multi-core computers but porting existing software in an efficient way is challenging.

  15. Geant4 hadronic and electromagnetic validation tests in LHCb

    CERN Multimedia

    Griffith, Peter Noel

    2016-01-01

    LHCb uses Geant4 to simulate the interactions of particles with the detector material and components. The simulation response can vary significantly due to modification of material description, of detector geometry, or of the Geant4 toolkit itself. Therefore, an extensive variety of tools have been developed to study the effects of Geant4 modification on the LHCb simulation framework and on stand-alone environments within the LHCb software infrastructure. These tools have proven to be very effective for investigating new and alternative models provided by Geant4, and also in identifying and fixing anomalous behaviours that arise from changes. The next goal is to have these validation tests run autonomously and periodically, alerting the relevant users when problems are detected. Quick and easy comparison of the results from different software versions and simulation models will be made possible through the web interface of the LHCb Performance and Regression testing system, LHCbPR.

  16. Geant4 used in medical physics and hadrontherapy technique

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    This article mainly presents the application of Geant4 package (Geant4.7.0, 2005), developed by CERN (the Center of European Research of Nucleus), in medical physics and a novel technique, namely, hadrontherapy. The distribution of energy deposition in a water model by different radiation beams was also given. The results show that the distributions for proton beams are completely different from those for other radiation beams. Charged particles like protons exhibit little scattering when they penetrate the matter and give the highest energy deposition near the end of their range just before they reach the resting state. These characteristics permit very precise control of the shape of the energy distribution inside the patient's body.

  17. Validation of Geant4 hadronic physics models at intermediate energies

    Science.gov (United States)

    Banerjee, Sunanda; Geant4 Hadronic Group

    2010-04-01

    GEANT4 provides a number of physics models at intermediate energies (corresponding to incident momenta in the range 1-20 GeV/c). Recently, these models have been validated with existing data from a number of experiments: (a) inclusive proton and neutron production with a variety of beams (π-, π+, p) at different energies between 1 and 9 GeV/c on a number of nuclear targets (from beryllium to uranium); (2) inclusive pion/kaon/proton production from 14.6 GeV/c proton beams on nuclear targets (from beryllium to gold); (3) inclusive pion production from pion beams between 3-13 GeV/c on a number of nuclear targets (from beryllium to lead). The results of simulation/data comparison for different GEANT4 models are discussed in the context of validating the models and determining their usage in physics lists for high energy application. Due to the increasing number of validations becoming available, and the requirement that they be done at regular intervals corresponding to the GEANT4 release schedule, automated methods of validation are being developed.

  18. Geant4 and beyond: recent progress in precision physics modeling

    CERN Document Server

    Batic, Matej; Han, Min Cheol; Hauf, Steffen; Hoff, Gabriela; Kim, Chan Hyeong; Kim, Han Sung; Kim, Sung Hun; Kuster, Markus; Pia, Maria Grazia; Saracco, Paolo; Weidenspointner, Georg

    2014-01-01

    This extended abstract briefly summarizes ongoing research activity on the evaluation and experimental validation of physics methods for photon and electron transport. The analysis includes physics models currently implemented in Geant4 as well as modeling methods used in other Monte Carlo codes, or not yet considered in general purpose Monte Carlo simulation systems. The validation of simulation models is performed with the support of rigorous statistical methods, which involve goodness-of-fit tests followed by categorical analysis. All results are quantitative, and are fully documented.

  19. Progress in Hadronic Physics Modelling in Geant4

    Energy Technology Data Exchange (ETDEWEB)

    Apostolakis, John; /CERN; Folger, Gunter; /CERN; Grichine, Vladimir; /CERN; Heikkinen, Aatos; /Helsinki Inst. of Phys.; Howard, Alexander; /CERN; Ivanchenko, Vladimir; /CERN; Kaitaniemi, Pekka; /Helsinki Inst. of Phys.; Koi, Tatsumi; /SLAC; Kosov, Mikhail; /CERN /Moscow, ITEP; Quesada, Jose Manuel; /Seville U.; Ribon, Alberto; /CERN; Uzhinsky, Vladimir; /CERN; Wright, Dennis; /SLAC

    2011-11-28

    Geant4 offers a set of models to simulate hadronic showers in calorimeters. Recent improvements to several models relevant to the modelling of hadronic showers are discussed. These include improved cross sections, a revision of the FTF model, the addition of quasi-elastic scattering to the QGS model, and enhancements in the nuclear precompound and de-excitation models. The validation of physics models against thin target experiments has been extended especially in the energy region 10 GeV and below. Examples of new validation results are shown.

  20. Recent Developments And Validations in Geant4 Hadronic Physics

    Energy Technology Data Exchange (ETDEWEB)

    Wright, D.H.; Koi, T.; Folger, G.; Ivanchenko, V.; Kossov, M.; Starkov, N.; Heikkinen, A.; Wellisch, H.P.; /SLAC /CERN /Helsinki Inst. of Phys.

    2007-02-12

    The Geant4 hadronic models cover the entire range of energies required by calorimeters in new and planned experiments. The extension and improvement of the elastic, cascade, parameterized and quark-gluon string models will be discussed. Such improvements include the extension to more particle types, a review and correction of cross sections, and a better treatment of energy and momentum conservation. Concurrent with this development has been a validation program which includes comparisons with double differential cross sections. An ongoing hadronic shower validation will also be discussed which includes the examination of longitudinal shower shapes and the performance of the above models as well as their interaction with electromagnetic processes such as multiple scattering.

  1. The Geant4-Based ATLAS Fast Electromagnetic Shower Simulation

    CERN Document Server

    Barberio, E; Butler, B; Cheung, S L; Dell'Acqua, A; Di Simone, A; Ehrenfeld, W; Gallas, M V; Glasow, A; Hughes, E; Marshall, Z; Müller, J; Placakyte, R; Rimoldi, A; Savard, P; Tsulaia, V; Waugh, A; Young, C C; 10th ICATPP Conference on Astroparticle, Particle, Space Physics, Detectors and Medical Physics Applications

    2008-01-01

    We present a three-pronged approach to fast electromagnetic shower simulation in ATLAS. Parameterisation is used for high-energy, shower libraries for medium-energy, and an averaged energy deposition for very low-energy particles. We present a comparison between the fast simulation and full simulation in an ATLAS Monte Carlo production.

  2. Introduction to the Geant4 Simulation toolkit

    Science.gov (United States)

    Guatelli, S.; Cutajar, D.; Oborn, B.; Rosenfeld, A. B.

    2011-05-01

    Geant4 is a Monte Carlo simulation Toolkit, describing the interactions of particles with matter. Geant4 is widely used in radiation physics research, from High Energy Physics, to medical physics and space science, thanks to its sophisticated physics component, coupled with advanced functionality in geometry description. Geant4 is widely used at the Centre for Medical Radiation Physics (CMRP), at the University of Wollongong, to characterise and optimise novel detector concepts, radiotherapy treatments, and imaging solutions. This lecture consists of an introduction to Monte Carlo method, and to Geant4. Particular attention will be devoted to the Geant4 physics component, and to the physics models describing electromagnetic and hadronic physics interactions. The second part of the lecture will be focused on the methodology to adopt to develop a Geant4 simulation application.

  3. GEANT4 in ALICE

    CERN Document Server

    Hrivnacova, I

    1999-01-01

    The smooth way of transition from existing GEANT3 based simulation software to GEANT4 adopted by ALICE will be explained. The AliRoot package as a client of the Monte Carlo interface (pure abstract class) is used in GEANT4 based classes for building GEANT4 objects (geometry physics list, primary generator). We shall also summarise our experience with GEANT4 and give an overview of what parts of GEANT4 are used in the current ALICE GEANT4 simulation prototype, what functionality has been added and what problems have been encountered.

  4. GEANT4 physics evaluation with testbeam data of the ATLAS hadronic end-cap calorimeter

    Science.gov (United States)

    Kiryunin, A. E.; Oberlack, H.; Salihagić, D.; Schacht, P.; Strizenec, P.

    2009-04-01

    The validation of GEANT4 physics models is done by comparing experimental data from beam tests of modules of the ATLAS hadronic end-cap calorimeter with GEANT4 based simulations. Various physics lists for the simulation of hadronic showers are evaluated. We present results of studies of the calorimeter performance parameters (like energy resolution and shower shapes) as well as results of investigations of the influence of the Birks' law and of cuts on the time of development of hadronic showers.

  5. Geant4 hadronic physics validation with ATLAS Tile Calorimeter test-beam data

    Science.gov (United States)

    Alexa, C.; Constantinescu, S.; DiÅ£ǎ, S.

    2006-10-01

    We present comparison studies between Geant4 shower packages and ATLAS Tile Calorimeter test-beam data collected at CERN in H8 beam line at the SPS. Emphasis is put on hadronic physics lists and data concerning differences between Tilecal response to pions and protons of same energy. The ratio between the pure hadronic fraction of pion and the pure hadronic fraction of proton Fhπ/Fhp was estimated with Tilecal test-beam data and compared with Geant4 simulations.

  6. Comparison of electromagnetic and hadronic models generated using Geant 4 with antiproton dose measured in CERN

    Directory of Open Access Journals (Sweden)

    Mohammad Bagher Tavakoli

    2015-01-01

    Full Text Available After proposing the idea of antiproton cancer treatment in 1984 many experiments were launched to investigate different aspects of physical and radiobiological properties of antiproton, which came from its annihilation reactions. One of these experiments has been done at the European Organization for Nuclear Research known as CERN using the antiproton decelerator. The ultimate goal of this experiment was to assess the dosimetric and radiobiological properties of beams of antiprotons in order to estimate the suitability of antiprotons for radiotherapy. One difficulty on this way was the unavailability of antiproton beam in CERN for a long time, so the verification of Monte Carlo codes to simulate antiproton depth dose could be useful. Among available simulation codes, Geant4 provides acceptable flexibility and extensibility, which progressively lead to the development of novel Geant4 applications in research domains, especially modeling the biological effects of ionizing radiation at the sub-cellular scale. In this study, the depth dose corresponding to CERN antiproton beam energy by Geant4 recruiting all the standard physics lists currently available and benchmarked for other use cases were calculated. Overall, none of the standard physics lists was able to draw the antiproton percentage depth dose. Although, with some models our results were promising, the Bragg peak level remained as the point of concern for our study. It is concluded that the Bertini model with high precision neutron tracking (QGSP_BERT_HP is the best to match the experimental data though it is also the slowest model to simulate events among the physics lists.

  7. Comparison of electromagnetic and hadronic models generated using Geant 4 with antiproton dose measured in CERN.

    Science.gov (United States)

    Tavakoli, Mohammad Bagher; Reiazi, Reza; Mohammadi, Mohammad Mehdi; Jabbari, Keyvan

    2015-01-01

    After proposing the idea of antiproton cancer treatment in 1984 many experiments were launched to investigate different aspects of physical and radiobiological properties of antiproton, which came from its annihilation reactions. One of these experiments has been done at the European Organization for Nuclear Research known as CERN using the antiproton decelerator. The ultimate goal of this experiment was to assess the dosimetric and radiobiological properties of beams of antiprotons in order to estimate the suitability of antiprotons for radiotherapy. One difficulty on this way was the unavailability of antiproton beam in CERN for a long time, so the verification of Monte Carlo codes to simulate antiproton depth dose could be useful. Among available simulation codes, Geant4 provides acceptable flexibility and extensibility, which progressively lead to the development of novel Geant4 applications in research domains, especially modeling the biological effects of ionizing radiation at the sub-cellular scale. In this study, the depth dose corresponding to CERN antiproton beam energy by Geant4 recruiting all the standard physics lists currently available and benchmarked for other use cases were calculated. Overall, none of the standard physics lists was able to draw the antiproton percentage depth dose. Although, with some models our results were promising, the Bragg peak level remained as the point of concern for our study. It is concluded that the Bertini model with high precision neutron tracking (QGSP_BERT_HP) is the best to match the experimental data though it is also the slowest model to simulate events among the physics lists.

  8. GEANT4 Hadronic Physics Validation with Lhc Test-Beam Data

    Science.gov (United States)

    Alexa, Călin

    2005-02-01

    In the framework of the LHC Computing Grid (LCG) Simulation Physics Validation Project, we present first conclusions about the validation of the Geant4 hadronic physics lists based on comparisons with test-beam data collected with three LHC calorimeters: the ATLAS Tilecal, the ATLAS HEC and the CMS HCAL.

  9. Validation of Geant4 physics models for {sup 56}Fe ion beam in various media

    Energy Technology Data Exchange (ETDEWEB)

    Jalota, Summit, E-mail: summit.jalota@gmail.com [Department of Physics, National Institute of Technology, Kurukshetra 136 119 (India); Kumar, Ashavani, E-mail: ashavani@yahoo.com [Department of Physics, National Institute of Technology, Kurukshetra 136 119 (India)

    2012-11-15

    The depth-dose distribution of a {sup 56}Fe ion beam has been studied in water, polyethylene, nextel, kevlar and aluminum media. The dose reduction versus areal depth is also calculated for {sup 56}Fe ions in carbon, polyethylene and aluminum using the Monte Carlo simulation toolkit Geant4. This study presents the validation of physics models available in Geant4 by comparing the simulated results with the experimental data available in the literature. Simulations are performed using binary cascade (BIC), abrasion-ablation (AA) and quantum molecular dynamics (QMD) models; integrated into Geant4. Deviations from experimental results may be due to the selection of simple geometry. This paper also addresses the differences in the simulated results from various models.

  10. Low-energy electron dose-point kernel simulations using new physics models implemented in Geant4-DNA

    Energy Technology Data Exchange (ETDEWEB)

    Bordes, Julien, E-mail: julien.bordes@inserm.fr [CRCT, UMR 1037 INSERM, Université Paul Sabatier, F-31037 Toulouse (France); UMR 1037, CRCT, Université Toulouse III-Paul Sabatier, F-31037 (France); Incerti, Sébastien, E-mail: incerti@cenbg.in2p3.fr [Université de Bordeaux, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); Lampe, Nathanael, E-mail: nathanael.lampe@gmail.com [Université de Bordeaux, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); Bardiès, Manuel, E-mail: manuel.bardies@inserm.fr [CRCT, UMR 1037 INSERM, Université Paul Sabatier, F-31037 Toulouse (France); UMR 1037, CRCT, Université Toulouse III-Paul Sabatier, F-31037 (France); Bordage, Marie-Claude, E-mail: marie-claude.bordage@inserm.fr [CRCT, UMR 1037 INSERM, Université Paul Sabatier, F-31037 Toulouse (France); UMR 1037, CRCT, Université Toulouse III-Paul Sabatier, F-31037 (France)

    2017-05-01

    When low-energy electrons, such as Auger electrons, interact with liquid water, they induce highly localized ionizing energy depositions over ranges comparable to cell diameters. Monte Carlo track structure (MCTS) codes are suitable tools for performing dosimetry at this level. One of the main MCTS codes, Geant4-DNA, is equipped with only two sets of cross section models for low-energy electron interactions in liquid water (“option 2” and its improved version, “option 4”). To provide Geant4-DNA users with new alternative physics models, a set of cross sections, extracted from CPA100 MCTS code, have been added to Geant4-DNA. This new version is hereafter referred to as “Geant4-DNA-CPA100”. In this study, “Geant4-DNA-CPA100” was used to calculate low-energy electron dose-point kernels (DPKs) between 1 keV and 200 keV. Such kernels represent the radial energy deposited by an isotropic point source, a parameter that is useful for dosimetry calculations in nuclear medicine. In order to assess the influence of different physics models on DPK calculations, DPKs were calculated using the existing Geant4-DNA models (“option 2” and “option 4”), newly integrated CPA100 models, and the PENELOPE Monte Carlo code used in step-by-step mode for monoenergetic electrons. Additionally, a comparison was performed of two sets of DPKs that were simulated with “Geant4-DNA-CPA100” – the first set using Geant4′s default settings, and the second using CPA100′s original code default settings. A maximum difference of 9.4% was found between the Geant4-DNA-CPA100 and PENELOPE DPKs. Between the two Geant4-DNA existing models, slight differences, between 1 keV and 10 keV were observed. It was highlighted that the DPKs simulated with the two Geant4-DNA’s existing models were always broader than those generated with “Geant4-DNA-CPA100”. The discrepancies observed between the DPKs generated using Geant4-DNA’s existing models and “Geant4-DNA-CPA100” were

  11. A Software Toolkit to Study Systematic Uncertainties of the Physics Models of the Geant4 Simulation Package

    Energy Technology Data Exchange (ETDEWEB)

    Genser, Krzysztof [Fermilab; Hatcher, Robert [Fermilab; Perdue, Gabriel [Fermilab; Wenzel, Hans [Fermilab; Yarba, Julia [Fermilab; Kelsey, Michael [SLAC; Wright, Dennis H. [SLAC

    2016-11-10

    The Geant4 toolkit is used to model interactions between particles and matter. Geant4 employs a set of validated physics models that span a wide range of interaction energies. These models are tuned to cover a large variety of possible applications. This raises the critical question of what uncertainties are associated with the Geant4 physics model, or group of models, involved in a simulation project. To address the challenge, we have designed and implemented a comprehen- sive, modular, user-friendly software toolkit that allows the variation of one or more parameters of one or more Geant4 physics models involved in simulation studies. It also enables analysis of multiple variants of the resulting physics observables of interest in order to estimate the uncertain- ties associated with the simulation model choices. Key functionalities of the toolkit are presented in this paper and are illustrated with selected results.

  12. A Software Toolkit to Study Systematic Uncertainties of the Physics Models of the Geant4 Simulation Package

    CERN Document Server

    Genser, Krzysztof; Perdue, Gabriel; Wenzel, Hans; Yarba, Julia; Kelsey, Michael; Wright, Dennis H

    2016-01-01

    The Geant4 toolkit is used to model interactions between particles and matter. Geant4 employs a set of validated physics models that span a wide range of interaction energies. These models are tuned to cover a large variety of possible applications. This raises the critical question of what uncertainties are associated with the Geant4 physics model, or group of models, involved in a simulation project. To address the challenge, we have designed and implemented a comprehen- sive, modular, user-friendly software toolkit that allows the variation of one or more parameters of one or more Geant4 physics models involved in simulation studies. It also enables analysis of multiple variants of the resulting physics observables of interest in order to estimate the uncertain- ties associated with the simulation model choices. Key functionalities of the toolkit are presented in this paper and are illustrated with selected results.

  13. Analysis of GEANT4 Physics List Properties in the 12 GeV MOLLER Simulation Framework

    Science.gov (United States)

    Haufe, Christopher; Moller Collaboration

    2013-10-01

    To determine the validity of new physics beyond the scope of the electroweak theory, nuclear physicists across the globe have been collaborating on future endeavors that will provide the precision needed to confirm these speculations. One of these is the MOLLER experiment - a low-energy particle experiment that will utilize the 12 GeV upgrade of Jefferson Lab's CEBAF accelerator. The motivation of this experiment is to measure the parity-violating asymmetry of scattered polarized electrons off unpolarized electrons in a liquid hydrogen target. This measurement would allow for a more precise determination of the electron's weak charge and weak mixing angle. While still in its planning stages, the MOLLER experiment requires a detailed simulation framework in order to determine how the project should be run in the future. The simulation framework for MOLLER, called ``remoll'', is written in GEANT4 code. As a result, the simulation can utilize a number of GEANT4 coded physics lists that provide the simulation with a number of particle interaction constraints based off of different particle physics models. By comparing these lists with one another using the data-analysis application ROOT, the most optimal physics list for the MOLLER simulation can be determined and implemented. This material is based upon work supported by the National Science Foundation under Grant No. 714001.

  14. Impact of the choice of physics list on GEANT4 simulations of hadronic showers in tungsten

    CERN Document Server

    Speckmayer, P

    2010-01-01

    The development of pion induced showers in a large block of matter (tungsten, lead, iron) is simulated for pions from 1 to 50GeV. Two GEANT4 physics lists (QGSP BERT and QGSP BERT HP) are compared. The deposited energy at each step of the simulation is identified as visible, invisible or escaped. It will be shown, that for tungsten in most of the hadronic showers more than 90% of the energy is deposited visibly if QGSP BERT is used. This fraction drops to only 60% for QGSP BERT HP. The latter fraction is similar to lead, even when QGSP BERT is used for the simulation. The impact of this behaviour on the energy resolution of a sampling calorimeter with scintillator as active material is shown. Although more energy is deposited visibly for QGSP BERT than for QGSP BERT HP, the reconstructed energy resolution is about 5 to 10% percent better for the latter.

  15. Validation of Geant4 Physics Using the CMS HCAL Test Beam 2002 Experiment

    CERN Document Server

    Elvira, Victor Daniel

    2004-01-01

    High energy physics measurements relay to a great extent on the accuracy of physics generators and detector simulations. The size of systematic uncertainties associated with particle discoveries, mass, or cross section measurements is tightly associated with how accurately the simulations describe the actual performance of the detector in measuring physics objects. Physics validation studies of Geant4 using physics lists LHEP-3.6 and QGSP-2.7, and based on HCAL test beam taken in 2002, are presented in this note. The pion energy resolution and response linearity as a function of incident energy derived from the simulations are in good agreement with the data measurement within the large systematics uncertainties in the latter. Below 30GeV, the uncertaintiesin the data are too large to provide information about deviationsof the Monte Carlo model with respect to the data measurements. Tr ansverse and longitudinal shower profiles are also studied in the Monte Carlo, but no data were analyzed. In particular, long...

  16. Physical Modelling of Proton and Heavy Ion Radiation using Geant4

    Directory of Open Access Journals (Sweden)

    Douglass M.

    2012-10-01

    Full Text Available Protons and heavy ion particles are considered to be ideal particles for use in external beam radiotherapy due to superior properties of the dose distribution that results when these particles are incident externally and due to their relative biological effectiveness. While significant research has been performed into the properties and physical dose characteristics of heavy ions, the nuclear reactions (direct and fragmentation undergone by He4, C12 and Ne20 nuclei used in radiotherapy in materials other than water is still largely unexplored. In the current project, input code was developed for the Monte Carlo toolkit Geant 4 version 9.3 to simulate the transport of several mono-energetic heavy ions through water. The relative dose contributions from secondary particles and nuclear fragments originating from the primary particles were investigated for each ion in both water and dense bone (ICRU media. The results indicated that the relative contribution to the total physical dose from nuclear fragments increased with both increasing particle mass and with increasing medium density. In the case of 150 MeV protons, secondary particles were shown to contribute less than 0.5% of the peak dose and as high as 25% when using 10570 MeV neon ions in bone. When water was substituted for a bone medium, the contributions from fragments increased by more than 6% for C12 and Ne20.

  17. Geant4 - A Simulation Toolkit

    Energy Technology Data Exchange (ETDEWEB)

    Wright, Dennis H

    2002-08-09

    GEANT4 is a toolkit for simulating the passage of particles through matter. it includes a complete range of functionality including tracking, geometry, physics models and hits. The physics processes offered cover a comprehensive range, including electromagnetic, hadronic and optical processes, a large set of long-lived particles, materials and elements, over a wide energy range starting, in some cases, from 250 eV and extending in others to the TeV energy range. it has been designed and constructed to expose the physics models utilized, to handle complex geometries, and to enable its easy adaptation for optimal use in different sets of applications. The toolkit is the result of a worldwide collaboration of physicists and software engineers. It has been created exploiting software engineering and object-oriented technology and implemented in the C++ programming language. It has been used in applications in particle physics, nuclear physics, accelerator design, space engineering and medical physics.

  18. GEANT4 A Simulation toolkit

    CERN Document Server

    Agostinelli, S; Amako, K; Apostolakis, John; Araújo, H M; Arce, P; Asai, M; Axen, D A; Banerjee, S; Barrand, G; Behner, F; Bellagamba, L; Boudreau, J; Broglia, L; Brunengo, A; Chauvie, S; Chuma, J; Chytracek, R; Cooperman, G; Cosmo, G; Degtyarenko, P V; Dell'Acqua, A; De Paola, G O; Dietrich, D D; Enami, R; Feliciello, A; Ferguson, C; Fesefeldt, H S; Folger, G; Foppiano, F; Forti, A C; Garelli, S; Giani, S; Giannitrapani, R; Gibin, D; Gómez-Cadenas, J J; González, I; Gracía-Abríl, G; Greeniaus, L G; Greiner, W; Grichine, V M; Grossheim, A; Gumplinger, P; Hamatsu, R; Hashimoto, K; Hasui, H; Heikkinen, A M; Howard, A; Hutton, A M; Ivanchenko, V N; Johnson, A; Jones, F W; Kallenbach, Jeff; Kanaya, N; Kawabata, M; Kawabata, Y; Kawaguti, M; Kelner, S; Kent, P; Kodama, T; Kokoulin, R P; Kossov, M; Kurashige, H; Lamanna, E; Lampen, T; Lara, V; Lefébure, V; Lei, F; Liendl, M; Lockman, W; Longo, F; Magni, S; Maire, M; Mecking, B A; Medernach, E; Minamimoto, K; Mora de Freitas, P; Morita, Y; Murakami, K; Nagamatu, M; Nartallo, R; Nieminen, P; Nishimura, T; Ohtsubo, K; Okamura, M; O'Neale, S W; O'Ohata, Y; Perl, J; Pfeiffer, A; Pia, M G; Ranjard, F; Rybin, A; Sadilov, S; Di Salvo, E; Santin, G; Sasaki, T; Savvas, N; Sawada, Y; Scherer, S; Sei, S; Sirotenko, V I; Smith, D; Starkov, N; Stöcker, H; Sulkimo, J; Takahata, M; Tanaka, S; Chernyaev, E; Safai-Tehrani, F; Tropeano, M; Truscott, P R; Uno, H; Urbàn, L; Urban, P; Verderi, M; Walkden, A; Wander, W; Weber, H; Wellisch, J P; Wenaus, T; Williams, D C; Wright, D; Yamada, T; Yoshida, H; Zschiesche, D

    2003-01-01

    Geant4 is a toolkit for simulating the passage of particles through matter. It includes a complete range of functionality including tracking, geometry, physics models and hits. The physics processes offered cover a comprehensive range, including electromagnetic, hadronic and optical processes, a large set of long-lived particles, materials and elements, over a wide energy range starting, in some cases, from 250 eV and extending in others to the TeV energy range. It has been designed and constructed to expose the physics models utilised, to handle complex geometries, and to enable its easy adaptation for optimal use in different sets of applications. The toolkit is the result of a worldwide collaboration of physicists and software engineers. It has been created exploiting software engineering and object-oriented technology and implemented in the C++ programming language. It has been used in applications in particle physics, nuclear physics, accelerator design, space engineering and medical physics.

  19. GEANT4--a simulation toolkit

    Energy Technology Data Exchange (ETDEWEB)

    Agostinelli, S.; Allison, J. E-mail: john.allison@man.ac.uk; Amako, K.; Apostolakis, J.; Araujo, H.; Arce, P.; Asai, M.; Axen, D.; Banerjee, S.; Barrand, G.; Behner, F.; Bellagamba, L.; Boudreau, J.; Broglia, L.; Brunengo, A.; Burkhardt, H.; Chauvie, S.; Chuma, J.; Chytracek, R.; Cooperman, G.; Cosmo, G.; Degtyarenko, P.; Dell' Acqua, A.; Depaola, G.; Dietrich, D.; Enami, R.; Feliciello, A.; Ferguson, C.; Fesefeldt, H.; Folger, G.; Foppiano, F.; Forti, A.; Garelli, S.; Giani, S.; Giannitrapani, R.; Gibin, D.; Gomez Cadenas, J.J.; Gonzalez, I.; Gracia Abril, G.; Greeniaus, G.; Greiner, W.; Grichine, V.; Grossheim, A.; Guatelli, S.; Gumplinger, P.; Hamatsu, R.; Hashimoto, K.; Hasui, H.; Heikkinen, A.; Howard, A.; Ivanchenko, V.; Johnson, A.; Jones, F.W.; Kallenbach, J.; Kanaya, N.; Kawabata, M.; Kawabata, Y.; Kawaguti, M.; Kelner, S.; Kent, P.; Kimura, A.; Kodama, T.; Kokoulin, R.; Kossov, M.; Kurashige, H.; Lamanna, E.; Lampen, T.; Lara, V.; Lefebure, V.; Lei, F.; Liendl, M.; Lockman, W.; Longo, F.; Magni, S.; Maire, M.; Medernach, E.; Minamimoto, K.; Mora de Freitas, P.; Morita, Y.; Murakami, K.; Nagamatu, M.; Nartallo, R.; Nieminen, P.; Nishimura, T.; Ohtsubo, K.; Okamura, M.; O' Neale, S.; Oohata, Y.; Paech, K.; Perl, J.; Pfeiffer, A.; Pia, M.G.; Ranjard, F.; Rybin, A.; Sadilov, S.; Di Salvo, E.; Santin, G.; Sasaki, T.; Savvas, N.; Sawada, Y.; Scherer, S.; Sei, S.; Sirotenko, V.; Smith, D.; Starkov, N.; Stoecker, H.; Sulkimo, J.; Takahata, M.; Tanaka, S.; Tcherniaev, E.; Safai Tehrani, E.; Tropeano, M.; Truscott, P.; Uno, H.; Urban, L.; Urban, P.; Verderi, M.; Walkden, A.; Wander, W.; Weber, H.; Wellisch, J.P.; Wenaus, T.; Williams, D.C.; Wright, D.; Yamada, T.; Yoshida, H.; Zschiesche, D

    2003-07-01

    GEANT4 is a toolkit for simulating the passage of particles through matter. It includes a complete range of functionality including tracking, geometry, physics models and hits. The physics processes offered cover a comprehensive range, including electromagnetic, hadronic and optical processes, a large set of long-lived particles, materials and elements, over a wide energy range starting, in some cases, from 250 eV and extending in others to the TeV energy range. It has been designed and constructed to expose the physics models utilised, to handle complex geometries, and to enable its easy adaptation for optimal use in different sets of applications. The toolkit is the result of a worldwide collaboration of physicists and software engineers. It has been created exploiting software engineering and object-oriented technology and implemented in the C++ programming language. It has been used in applications in particle physics, nuclear physics, accelerator design, space engineering and medical physics.

  20. Validation of recent Geant4 physics models for application in carbon ion therapy

    CERN Document Server

    Lechner, A; Ivanchenko, V N

    2010-01-01

    Cancer treatment with energetic carbon ions has distinct advantages over proton or photon irradiation. In this paper we present a simulation model integrated into the Geant4 Monte Carlo toolkit (version 9.3) which enables the use of ICRU 73 stopping powers for ion transport calculations. For a few materials, revised ICRU 73 stopping power tables recently published by ICRU (P. Sigmund, A. Schinner, H. Paul, Errata and Addenda: ICRU Report 73 (Stopping of Ions Heavier than Helium), International Commission on Radiation Units and Measurements, 2009) were incorporated into Geant4, also covering media like water which are of importance in radiotherapeutical applications. We examine, with particular attention paid to the recent developments, the accuracy of current Geant4 models for simulating Bragg peak profiles of C-12 ions incident on water and polyethylene targets. Simulated dose distributions are validated against experimental data available in the literature, where the focus is on beam energies relevant to io...

  1. Applications of Geant4 toolkit to implosion physics for inertial confinement fusion experiments%Geant4在惯性约束聚变内爆物理中的应用

    Institute of Scientific and Technical Information of China (English)

    苏明; 余波; 宋天明; 何小安; 郑建华; 黄天晅; 刘慎业; 江少恩

    2013-01-01

    基于Geant4建立了内爆物理实验多种诊断设备的全三维仿真模型,包括中子成像系统、用于硬X射线诊断的滤波应光谱仪、楔形滤片质子能谱仪、化学气相沉积金刚石探测器(CVD)等.根据Geant4仿真模拟的数据,建立了合适的解谱及图像还原算法,优化了系统设计,从理论上预估了诊断设备的诊断能力.此外仿真数据亦用于设计实验方案,建立诊断设备的标定方法等.%Several diagnostic systems used in implosion physics research were modeled by Geant4 toolkit,including the neutron imaging system,the filter-fluorescer spectrometer for hard X-ray diagnostic,the wedged-range filter spectrometer for proton diagnostic,the CVD diamond detector for neutron diagnostics,etc.The Geant4 simulation results were used to establish proper spectrum and images reconstructed algorithm,to optimize system design,and to estimate diagnostic system performance.Besides,based on the simulation,an experiment scheme was designed and calibration methods for the diagnostics were established.

  2. Comparison of the neutron ambient dose equivalent and ambient absorbed dose calculations with different GEANT4 physics lists

    Science.gov (United States)

    Ribeiro, Rosane Moreira; Souza-Santos, Denison

    2017-10-01

    A comparison between neutron physics lists given by GEANT4, is made in the calculation of the ambient dose equivalent, and ambient absorbed dose, per fluence conversion coefficients (H* (10) / ϕ and D* (10) / ϕ) for neutrons in the range of 10-9 MeV to 15 MeV. Physics processes are included for neutrons, photons and charged particles, and calculations are made for neutrons and secondary particles. Results obtained for QBBC, QGSP_BERT, QGSP_BIC and Neutron High Precision physics lists are compared with values published in ICRP 74 and previously published articles. Neutron high precision physics lists showed the best results in the studied energy range.

  3. ROSI and GEANT4 – A comparison in the context of high energy X-ray physics

    Energy Technology Data Exchange (ETDEWEB)

    Kiunke, Markus [Chair of X-ray Microscopy, University Würzburg, Josef-Martin-Weg 63, 97074 Würzburg (Germany); Stritt, Carina, E-mail: Carina.Stritt@empa.ch [Empa, Swiss Federal Laboratories for Material Science and Technology, Reliability Science and Technology, Überlandstrasse 129, 8600 Dübendorf (Switzerland); Schielein, Richard [Chair of X-ray Microscopy, University Würzburg, Josef-Martin-Weg 63, 97074 Würzburg (Germany); Sukowski, Frank; Hölzing, Astrid [Fraunhofer Development Center for X-ray Technology EZRT, Flugplatzstr. 75, 90768 Fürth (Germany); Zabler, Simon [Chair of X-ray Microscopy, University Würzburg, Josef-Martin-Weg 63, 97074 Würzburg (Germany); Fraunhofer Development Center for X-ray Technology EZRT, Flugplatzstr. 75, 90768 Fürth (Germany); Hofmann, Jürgen; Flisch, Alexander [Empa, Swiss Federal Laboratories for Material Science and Technology, Center for X-ray Analytics, Überlandstrasse 129, 8600 Dübendorf (Switzerland); Kasperl, Stefan [Fraunhofer Development Center for X-ray Technology EZRT, Flugplatzstr. 75, 90768 Fürth (Germany); Sennhauser, Urs [Empa, Swiss Federal Laboratories for Material Science and Technology, Reliability Science and Technology, Überlandstrasse 129, 8600 Dübendorf (Switzerland); and others

    2016-06-15

    This work compares two popular MC simulation frameworks ROSI (Roentgen Simulation) and GEANT4 (Geometry and Tracking in its fourth version) in the context of X-ray physics. The comparison will be performed with the help of a parameter study considering energy, material and length variations. While the total deposited energy as well as the contribution of Compton scattering show a good accordance between all simulated configurations, all other physical effects exhibit large deviations in a comparison of data-sets. These discrepancies between simulations are shown to originate from the different cross sectional databases used in the frameworks, whereas the overall simulation mechanics seem to not have an influence on the agreement of the simulations. A scan over energy, length and material shows that the two parameters energy and material have a significant influence on the agreement of the simulation results, while the length parameter shows no noticeable influence on the deviations between the data-sets.

  4. Geant4 models for space radiation environment.

    Science.gov (United States)

    Ivantchenko, Anton; Nieminen, Petteri; Incerti, Sebastien; Santin, Giovanni; Ivantchenko, Vladimir; Grichine, Vladimir; Allison, John

    The space radiation environment includes wide varieties of particles from electrons to heavy ions. In order to correctly predict the dose received by astronauts and devices the simulation models must have good applicability and produce accurate results from 10 MeV/u up to 10 GeV/u, where the most radioactive hazardous particles are present in the spectra. Appropriate models should also provide a good description of electromagnetic interactions down to very low energies (10 eV/u - 10 MeV/u) for understanding the damage mechanisms due to long-term low doses. Predictions of biological dose during long interplanetary journeys also need models for hadronic interactions of energetic heavy ions extending higher energies (10 GeV/u - 100 GeV/u, but possibly up to 1 TeV/u). Geant4 is a powerful toolkit, which in some areas well surpasses the needs from space radiation studies, while in other areas is being developed and/or validated to properly cover the modelling requirements outlined above. Our activities in ESA projects deal with the research and development of both Geant4 hadronic and electromagnetic physics. Recently the scope of verification tests and benchmarks has been extended. Hadronic tests and benchmarks run proton, pion, and ion interactions with matter at various energies. In the Geant4 hadronic sub-libraries, the most accurate cross sections have been identified and selected as a default for all particle types relevant to space applications. Significant developments were carried out for ion/ion interaction models. These now allow one to perform Geant4 simulations for all particle types and energies relevant to space applications. For the validation of ion models the hadronic testing suite for ion interactions was significantly extended. In this work the results of benchmarking versus data in a wide energy range for projectile protons and ions will be shown and discussed. Here we show results of the tests runs and their precision. Recommendations for Geant4

  5. In-beam quality assurance using induced β+ activity in hadrontherapy: a preliminary physical requirements study using Geant4

    Science.gov (United States)

    Lestand, L.; Montarou, G.; Force, P.; Pauna, N.

    2012-10-01

    Light and heavy ions particle therapy, mainly by means of protons and carbon ions, represents an advantageous treatment modality for deep-seated and/or radioresistant tumours. An in-beam quality assurance principle is based on the detection of secondary particles induced by nuclear fragmentations between projectile and target nuclei. Three different strategies are currently under investigation: prompt γ rays imaging, proton interaction vertex imaging and in-beam positron emission tomography. Geant4 simulations have been performed first in order to assess the accuracy of some hadronic models to reproduce experimental data. Two different kinds of data have been considered: β+-emitting isotopes and prompt γ-ray production rates. On the one hand simulations reproduce experimental β+ emitting isotopes production rates to an accuracy of 24%. Moreover simulated β+ emitting nuclei production rate as a function of depth reproduce well the peak-to-plateau ratio of experimental data. On the other hand by tuning the tolerance factor of the photon evaporation model available in Geant4, we reduce significantly prompt γ-ray production rates until a very good agreement is reached with experimental data. Then we have estimated the total amount of induced annihilation photons and prompt γ rays for a simple treatment plan of ∼1 physical Gy in a homogenous equivalent soft tissue tumour (6 cm depth, 4 cm radius and 2 cm wide). The average annihilation photons emitted during a 45 s irradiation in a 4 π solid angle are ∼2 × 106 annihilation photon pairs and 108 single prompt γ whose energy ranges from a few keV to 10 MeV.

  6. In-beam quality assurance using induced β(+) activity in hadrontherapy: a preliminary physical requirements study using Geant4.

    Science.gov (United States)

    Lestand, L; Montarou, G; Force, P; Pauna, N

    2012-10-21

    Light and heavy ions particle therapy, mainly by means of protons and carbon ions, represents an advantageous treatment modality for deep-seated and/or radioresistant tumours. An in-beam quality assurance principle is based on the detection of secondary particles induced by nuclear fragmentations between projectile and target nuclei. Three different strategies are currently under investigation: prompt γ rays imaging, proton interaction vertex imaging and in-beam positron emission tomography. Geant4 simulations have been performed first in order to assess the accuracy of some hadronic models to reproduce experimental data. Two different kinds of data have been considered: β(+)-emitting isotopes and prompt γ-ray production rates. On the one hand simulations reproduce experimental β(+) emitting isotopes production rates to an accuracy of 24%. Moreover simulated β(+) emitting nuclei production rate as a function of depth reproduce well the peak-to-plateau ratio of experimental data. On the other hand by tuning the tolerance factor of the photon evaporation model available in Geant4, we reduce significantly prompt γ-ray production rates until a very good agreement is reached with experimental data. Then we have estimated the total amount of induced annihilation photons and prompt γ rays for a simple treatment plan of ∼1 physical Gy in a homogenous equivalent soft tissue tumour (6 cm depth, 4 cm radius and 2 cm wide). The average annihilation photons emitted during a 45 s irradiation in a 4 π solid angle are ∼2 × 10(6) annihilation photon pairs and 10(8) single prompt γ whose energy ranges from a few keV to 10 MeV.

  7. An Overview of the Geant4 Toolkit

    CERN Document Server

    Apostolakis, John

    2007-01-01

    Geant4 is a toolkit for the simulation of the transport of radiation trough matter. With a flexible kernel and choices between different physics modeling choices, it has been tailored to the requirements of a wide range of applications. With the toolkit a user can describe a setup's or detector's geometry and materials, navigate inside it, simulate the physical interactions using a choice of physics engines, underlying physics cross-sections and models, visualise and store results. Physics models describing electromagnetic and hadronic interactions are provided, as are decays and processes for optical photons. Several models, with different precision and performance are available for many processes. The toolkit includes coherent physics model configurations, which are called physics lists. Users can choose an existing physics list or create their own, depending on their requirements and the application area. A clear structure and readable code, enable the user to investigate the origin of physics results. App...

  8. Experiences on Grid Production for GEANT4

    CERN Document Server

    Lamanna, M; Méndez-Lorenzo, P; Moscicki, J; Ribon, A

    2007-01-01

    Geant4 is a worldwide collaboration of scientists and software engineers whose goal is to develop, maintain and provide support for the Geant4 package, representing a general purpose Monte Carlo toolkit for simulating the propagation of particles through matter. Geant4 is currently employed in a row of particle physics experiments (BaBar, HARP, ATLAS, CMS, LHCb), and is also applied in other areas like space science, medical applications, and radiation studies. Due to the complexity of the Geant4 code and to the broad spectrum of possible configurations - involving a variety of physical processes for different source particles, particle energies and target or shielding materials - an intensive testing of new release candidates is mandatory to thoroughly test each of its components, especially before major releases, generally twice a year. Regression tests are required to be performed by the Geant4 team within a short period of time (2 to 3 weeks), basically demanding vast computational resources (equivalent t...

  9. The performance of the geant4 standard EM package for LHC and other applications

    CERN Document Server

    Apostolakis, J; Elles, S; Ivanchenko, V N; Kadri, O; Maire, M; Urbàn, L

    2008-01-01

    Current status of the Standard electro-magnetic (EM) package of the Geant4 toolkit is described. We report on the stability of results with respect to variation of production threshold and Physics List. This illustrates the trade between CPU time and precision of simulation predictions. New comparisons of the Geant4 simulation with the experimental data are shown. The CPU benchmark results are discussed.

  10. Recent developments in GEANT4

    Science.gov (United States)

    Allison, J.; Amako, K.; Apostolakis, J.; Arce, P.; Asai, M.; Aso, T.; Bagli, E.; Bagulya, A.; Banerjee, S.; Barrand, G.; Beck, B. R.; Bogdanov, A. G.; Brandt, D.; Brown, J. M. C.; Burkhardt, H.; Canal, Ph.; Cano-Ott, D.; Chauvie, S.; Cho, K.; Cirrone, G. A. P.; Cooperman, G.; Cortés-Giraldo, M. A.; Cosmo, G.; Cuttone, G.; Depaola, G.; Desorgher, L.; Dong, X.; Dotti, A.; Elvira, V. D.; Folger, G.; Francis, Z.; Galoyan, A.; Garnier, L.; Gayer, M.; Genser, K. L.; Grichine, V. M.; Guatelli, S.; Guèye, P.; Gumplinger, P.; Howard, A. S.; Hřivnáčová, I.; Hwang, S.; Incerti, S.; Ivanchenko, A.; Ivanchenko, V. N.; Jones, F. W.; Jun, S. Y.; Kaitaniemi, P.; Karakatsanis, N.; Karamitrosi, M.; Kelsey, M.; Kimura, A.; Koi, T.; Kurashige, H.; Lechner, A.; Lee, S. B.; Longo, F.; Maire, M.; Mancusi, D.; Mantero, A.; Mendoza, E.; Morgan, B.; Murakami, K.; Nikitina, T.; Pandola, L.; Paprocki, P.; Perl, J.; Petrović, I.; Pia, M. G.; Pokorski, W.; Quesada, J. M.; Raine, M.; Reis, M. A.; Ribon, A.; Ristić Fira, A.; Romano, F.; Russo, G.; Santin, G.; Sasaki, T.; Sawkey, D.; Shin, J. I.; Strakovsky, I. I.; Taborda, A.; Tanaka, S.; Tomé, B.; Toshito, T.; Tran, H. N.; Truscott, P. R.; Urban, L.; Uzhinsky, V.; Verbeke, J. M.; Verderi, M.; Wendt, B. L.; Wenzel, H.; Wright, D. H.; Wright, D. M.; Yamashita, T.; Yarba, J.; Yoshida, H.

    2016-11-01

    GEANT4 is a software toolkit for the simulation of the passage of particles through matter. It is used by a large number of experiments and projects in a variety of application domains, including high energy physics, astrophysics and space science, medical physics and radiation protection. Over the past several years, major changes have been made to the toolkit in order to accommodate the needs of these user communities, and to efficiently exploit the growth of computing power made available by advances in technology. The adaptation of GEANT4 to multithreading, advances in physics, detector modeling and visualization, extensions to the toolkit, including biasing and reverse Monte Carlo, and tools for physics and release validation are discussed here.

  11. Nuclear spectroscopy with Geant4

    Directory of Open Access Journals (Sweden)

    Sarmiento Luis G.

    2016-01-01

    Full Text Available The simulation toolkit Geant4 was originally developed at CERN for high-energy physics. Over the years it has been established as a swiss army knife not only in particle physics but it has seen an accelerated expansion towards nuclear physics and more recently to medical imaging and γ- and ion- therapy to mention but a handful of new applications. The validity of Geant4 is vast and large across many particles, ions, materials, and physical processes with typically various different models to choose from. Unfortunately, atomic nuclei with atomic number Z > 100 are not properly supported. This is likely due to the rather novelty of the field, its comparably small user base, and scarce evaluated experimental data. To circumvent this situation different workarounds have been used over the years. In this work the simulation toolkit Geant4 will be introduced with its different components and the effort to bring the software to the heavy and superheavy region will be described.

  12. Comparison of Geant4 with EGSnrc for Simulation of Gamma-Radiation Detectors Based on Semi-Insulating Materials

    CERN Document Server

    Skrypnyk, A I; Khazhmuradov, M A

    2011-01-01

    We considered GEANT4 version 4.9.4 with different Electromagnetic Physics Package for calculation of response functions of detectors based on semi-insulating materials. Computer simulations with GEANT4 packages were run in order to determine the energy deposition of gamma-quanta in detectors of specified composition (Mercuric (II) Iodide and Thallium Bromide) at various energies from 0.026 to 3 MeV. The uncertainty in these predictions is estimated by comparison of their results with EGSnrc simulations. A general good agreement is found for EGSnrc and GEANT4 with Penelope 2008 model of LowEnergy Electromagnetic package.

  13. Exploring the Physics Limitations of Compact High Gradient Accelerating Structures Simulations of the Electron Current Spectrometer Setup in Geant4

    CERN Document Server

    Van Vliet, Philine Julia

    2017-01-01

    The high field gradient of 100 MV/m that will be applied to the accelerator cavities of the Compact Linear Collider (CLIC), gives rise to the problem of RF breakdowns. The field collapses and a plasma of electrons and ions is being formed in the cavity, preventing the RF field from penetrating the cavity. Electrons in the plasma are being accelerated and ejected out, resulting in a breakdown current up to a few Amp`eres, measured outside the cavities. These breakdowns lead to luminosity loss, so reducing their amount is of great importance. For this, a better understanding of the physics behind RF breakdowns is needed. To study these breakdowns, the XBox 2 test facility has a spectrometer setup installed after the RF cavity that is being conditioned. For this report, a simulation of this spectrometer setup has been made using Geant4. Once a detailed simulation of the RF field and cavity has been made, it can be connected to this simulation of the spectrometer setup and used to recreate the data that has b...

  14. Effect of Different Geant4 Physical Models on Simulation of Radiotherapy Proton Beam%Geant4不同物理模型对放疗质子束模拟的影响

    Institute of Scientific and Technical Information of China (English)

    林辉; 谢聪; 张拥军; 熊桢宇; 吴东升; 曹瑞芬; FDS团队

    2015-01-01

    The Monte Carlo method is usually used to simulate the feature of the exter‐nal radiotherapy of proton beam to optimize the clinical therapy scenario .T he selection of a suitable physical model is very critical to ensure the correction and the efficiency of the simulation .This work studied nine Geant4 physical models ,which are often used in the simulation of radiotherapy of proton beam with energy of 60‐250 MeV .The dosage features and the microcosmic secondary yields in different materials were compared .The result show s that ,although the standard EM ,the low energy Penelope model and the low energy Livermore model can output the right dose distribution ,they can’t simulate the baryon yields .The parametrization driven model LHEP and the Quark gluon string‐pre‐compound model both can’ t simulate the complex ion transportation . Thus the above five models are not enough for the research calculation in the radiation protection and the radiation damage .The QGSP_BIC_EMY model in Geant4 hadron therapy exam‐ple is very bad for underestimating the dose ratio of Bragg peak to entrance and absolute dose .The QGSP_BERT model ,QGSP_BIC model and FTFP_BERT model are suitable for the radiotherapy proton beam with energy of 60‐250 MeV .%Monte Carlo方法常用于质子束剂量模拟以优化质子束临床治疗,合适的物理模型选择关系到M onte Carlo模拟结果的可靠性及模拟效率。本工作选取9个可用于质子模拟的Geant4物理模型,计算比较了质子束在多种介质中的剂量及次级粒子产额。结果表明:标准电磁物理模型、低能电磁Penel‐ope模型和Livermore模型虽在模拟质子整体剂量分布上可接受,但在微观上缺失重粒子生成。参数化驱动模型LHEP的模拟时间最短,但与QGSP相同,均不能产生复杂重离子。QGSP_BIC_EMY模型较其他模型明显低估Bragg峰‐入口剂量比和绝对剂量。QGSP_BERT 模型、QGSP_BIC模型和 FT FP

  15. Validation of Hadronic Models in GEANT4

    Energy Technology Data Exchange (ETDEWEB)

    Koi, Tatsumi; Wright, Dennis H.; /SLAC; Folger, Gunter; Ivanchenko, Vladimir; Kossov, Mikhail; Starkov, Nikolai; /CERN; Heikkinen, Aatos; /Helsinki Inst. of Phys.; Truscott,; Lei, Fan; /QinetiQ; Wellisch, Hans-Peter

    2007-09-26

    Geant4 is a software toolkit for the simulation of the passage of particles through matter. It has abundant hadronic models from thermal neutron interactions to ultra relativistic hadrons. An overview of validations in Geant4 hadronic physics is presented based on thin target measurements. In most cases, good agreement is available between Monte Carlo prediction and experimental data; however, several problems have been detected which require some improvement in the models.

  16. Validation of hadronic models in GEANT4

    CERN Document Server

    Koi, Tatsumi; Folger, Günter; Ivanchenko, Vladimir; Kossov, Mikhail; Starkov, Nikolai; Heikkinen, Aatos; Truscott, Pete; Lei, Fan; Wellisch, Hans-Peter

    2007-01-01

    Geant4 is a software toolkit for the simulation of the passage of particles through matter. It has abundant hadronic models from thermal neutron interactions to ultra relativistic hadrons. An overview of validations in Geant4 hadronic physics is presented based on thin-target measurements. In most cases, good agreement is available between Monte Carlo prediction and experimental data; however, several problems have been detected which require some improvement in the models.

  17. The GEANT4 Visualisation System

    Energy Technology Data Exchange (ETDEWEB)

    Allison, J.; /Manchester U.; Asai, M.; /SLAC; Barrand, G.; /Orsay; Donszelmann, M.; /SLAC; Minamimoto, K.; /Inst. Comput. Fluid Dyn., Tokyo; Tanaka, S.; /Ritsumeikan U.; Tcherniaev, E.; /CERN; Tinslay, J.; /SLAC

    2007-11-02

    The Geant4 Visualization System is a multi-driver graphics system designed to serve the Geant4 Simulation Toolkit. It is aimed at the visualization of Geant4 data, primarily detector descriptions and simulated particle trajectories and hits. It can handle a variety of graphical technologies simultaneously and interchangeably, allowing the user to choose the visual representation most appropriate to requirements. It conforms to the low-level Geant4 abstract graphical user interfaces and introduces new abstract classes from which the various drivers are derived and that can be straightforwardly extended, for example, by the addition of a new driver. It makes use of an extendable class library of models and filters for data representation and selection. The Geant4 Visualization System supports a rich set of interactive commands based on the Geant4 command system. It is included in the Geant4 code distribution and maintained and documented like other components of Geant4.

  18. GEANT4-MT : bringing multi-threading into GEANT4 production

    Science.gov (United States)

    Ahn, Sunil; Apostolakis, John; Asai, Makoto; Brandt, Daniel; Cooperman, Gene; Cosmo, Gabriele; Dotti, Andrea; Dong, Xin; Jun, Soon Yung; Nowak, Andrzej

    2014-06-01

    GEANT4-MT is the multi-threaded version of the GEANT4 particle transport code.(1, 2) The key goals for the design of GEANT4-MT have been a) the need to reduce the memory footprint of the multi-threaded application compared to the use of separate jobs and processes; b) to create an easy migration of the existing applications; and c) to use efficiently many threads or cores, by scaling up to tens and potentially hundreds of workers. The first public release of a GEANT4-MT prototype was made in 2011. We report on the revision of GEANT4-MT for inclusion in the production-level release scheduled for end of 2013. This has involved significant re-engineering of the prototype in order to incorporate it into the main GEANT4 development line, and the porting of GEANT4-MT threading code to additional platforms. In order to make the porting of applications as simple as possible, refinements addressed the needs of standalone applications. Further adaptations were created to improve the fit with the frameworks of High Energy Physics (HEP) experiments. We report on performances measurements on Intel Xeon™, AMD Opteron™ the first trials of GEANT4-MT on the Intel Many Integrated Cores (MIC) architecture, in the form of the Xeon Phi™ co-processor.(3) These indicate near-linear scaling through about 200 threads on 60 cores, when holding fixed the number of events per thread.

  19. Validation Test of Geant4 Simulation of Electron Backscattering

    CERN Document Server

    Kim, Sung Hun; Basaglia, Tullio; Han, Min Cheol; Hoff, Gabriela; Kim, Chan Hyeong; Saracco, Paolo

    2015-01-01

    Backscattering is a sensitive probe of the accuracy of electron scattering algorithms implemented in Monte Carlo codes. The capability of the Geant4 toolkit to describe realistically the fraction of electrons backscattered from a target volume is extensively and quantitatively evaluated in comparison with experimental data retrieved from the literature. The validation test covers the energy range between approximately 100 eV and 20 MeV, and concerns a wide set of target elements. Multiple and single electron scattering models implemented in Geant4, as well as preassembled selections of physics models distributed within Geant4, are analyzed with statistical methods. The evaluations concern Geant4 versions from 9.1 to 10.1. Significant evolutions are observed over the range of Geant4 versions, not always in the direction of better compatibility with experiment. Goodness-of-fit tests complemented by categorical analysis tests identify a configuration based on Geant4 Urban multiple scattering model in Geant4 vers...

  20. Comparisons of the Electron and Muon Testbeam Response of the ATLAS Liquid Argon Calorimeters with GEANT4 Simulations

    CERN Document Server

    Benchekroun, D; Karapetian, G V; Kiryunin, A E; Kish, J; Kordas, K; Leltchouk, M; Loch, P; Mazini, R; Negroni, S; Parrour, G; Salihagic, D; Seligman, W; Soukharev, A M; Strízenec, P; Unal, G

    2004-01-01

    GEANT4, a new simulation toolkit, is now in use by the different sub-detectors which are currently being built and tested for the ATLAS experiment. The validation of the GEANT4 electromagnetic physics is done by comparing the response of the various modules of the ATLAS liquid argon calorimeters to electron and muon test beams to the results of GEANT4 simulations. Comparisons to the corresponding GEANT3 predictions has been done as well. This note presents the status of the work on this validation.

  1. Comparison of GEANT4 very low energy cross section models with experimental data in water

    Energy Technology Data Exchange (ETDEWEB)

    Incerti, S.; Ivanchenko, A.; Karamitros, M.; Mantero, A.; Moretto, P.; Tran, H. N.; Mascialino, B.; Champion, C.; Ivanchenko, V. N.; Bernal, M. A.; Francis, Z.; Villagrasa, C.; Baldacchino, G.; Gueye, P.; Capra, R.; Nieminen, P.; Zacharatou, C. [Universite Bordeaux 1, CNRS/IN2P3, Centre d' Etudes Nucleaires de Bordeaux-Gradignan, CENBG, Chemin du Solarium, BP 120, 33175 Gradignan (France); Karolinska Institutet, P.O. Box 260, S-171-76 Stockholm (Sweden); Laboratoire de Physique Moleculaire et des Collisions, Universite Paul Verlaine-Metz, 1 Boulevard Arago, Technopo circumflex le 2000, 57078 Metz (France); Departamento de Fisica, Universidad Simon Bolivar, P.O. Box 89000, Caracas 1080-A (Venezuela, Bolivarian Republic of); IRSN, Institut de Radioprotection et de Surete Nucleaire, BP17, 92262 Fontenay-aux-Roses (France); CEA Saclay, IRAMIS, UMR 3299 CEA-CNRS SIS2M, Laboratoire de Radiolyse, F-91191 Gif-sur-Yvette Cedex (France); Department of Physics, Hampton University, Hampton, Virginia 23668 (United States); Via Niella 12, 17100 Savona (Italy); ESA-ESTEC, 2200 AG Noordwijk (Netherlands); Niels Bohr Institute, Blegdamsvej 17, 2100 Copenhagen (Denmark)

    2010-09-15

    Purpose: The GEANT4 general-purpose Monte Carlo simulation toolkit is able to simulate physical interaction processes of electrons, hydrogen and helium atoms with charge states (H{sup 0}, H{sup +}) and (He{sup 0}, He{sup +}, He{sup 2+}), respectively, in liquid water, the main component of biological systems, down to the electron volt regime and the submicrometer scale, providing GEANT4 users with the so-called ''GEANT4-DNA'' physics models suitable for microdosimetry simulation applications. The corresponding software has been recently re-engineered in order to provide GEANT4 users with a coherent and unique approach to the simulation of electromagnetic interactions within the GEANT4 toolkit framework (since GEANT4 version 9.3 beta). This work presents a quantitative comparison of these physics models with a collection of experimental data in water collected from the literature. Methods: An evaluation of the closeness between the total and differential cross section models available in the GEANT4 toolkit for microdosimetry and experimental reference data is performed using a dedicated statistical toolkit that includes the Kolmogorov-Smirnov statistical test. The authors used experimental data acquired in water vapor as direct measurements in the liquid phase are not yet available in the literature. Comparisons with several recommendations are also presented. Results: The authors have assessed the compatibility of experimental data with GEANT4 microdosimetry models by means of quantitative methods. The results show that microdosimetric measurements in liquid water are necessary to assess quantitatively the validity of the software implementation for the liquid water phase. Nevertheless, a comparison with existing experimental data in water vapor provides a qualitative appreciation of the plausibility of the simulation models. The existing reference data themselves should undergo a critical interpretation and selection, as some of the series

  2. GEANT4 tuning for pCT development

    Energy Technology Data Exchange (ETDEWEB)

    Yevseyeva, Olga; Assis, Joaquim T. de [Universidade do Estado do Rio de Janeiro (IPRJ/UERJ), Nova Friburgo, RJ (Brazil). Inst. Politecnico; Evseev, Ivan; Schelin, Hugo R.; Paschuk, Sergei A.; Milhoretto, Edney; Setti, Joao A.P. [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil); Diaz, Katherin S. [Centro de Aplicaciones Tecnologicas y Desarrollo Nuclear, Havana (Cuba); Hormaza, Joel M. [Universidade Estadual Paulista Julio de Mesquisa Filho (DFB/IB/UNESP), Botucatu, SP (Brazil). Inst. de Biociencias. Dept. de Fisica e Biofisica; Lopes, Ricardo T. [Coordenacao dos Programas de Pos-Graduacao de Engenharia (COPPE/UFRJ), RJ (Brazil). Lab. de Instrumentacao Nuclear

    2010-07-01

    Full text. Proton beams in medical applications deal with relatively thick targets like the human head or trunk. Thus, the fidelity of proton computed tomography (pCT) simulations as a tool for proton therapy planning depends in the general case on the accuracy of results obtained for the proton interaction with thick absorbers.GEANT4 simulations of proton energy spectra after passing thick absorbers do not agree well with existing experimental data, as showed previously. Moreover, the spectra simulated for the Bethe-Bloch domain showed an unexpected sensitivity to the choice of low-energy electromagnetic models during the code execution. These observations were done with the GEANT4 version 8.2 during our simulations for pCT. This work describes in more details the simulations of the proton passage through aluminum absorbers with varied thickness. The simulations were done by modifying only the geometry in the Hadron therapy Example, and for all available choices of the Electromagnetic Physics Models. As the most probable reasons for these effects is some specific feature in the code, or some specific implicit parameters in the GEANT4 manual, we continued our study with version 9.2 of the code. Some improvements in comparison with our previous results were obtained. The simulations were performed considering further applications for pCT development. (author)

  3. GEANT4 Tuning For pCT Development

    Science.gov (United States)

    Yevseyeva, Olga; de Assis, Joaquim T.; Evseev, Ivan; Schelin, Hugo R.; Paschuk, Sergei A.; Milhoretto, Edney; Setti, João A. P.; Díaz, Katherin S.; Hormaza, Joel M.; Lopes, Ricardo T.

    2011-08-01

    Proton beams in medical applications deal with relatively thick targets like the human head or trunk. Thus, the fidelity of proton computed tomography (pCT) simulations as a tool for proton therapy planning depends in the general case on the accuracy of results obtained for the proton interaction with thick absorbers. GEANT4 simulations of proton energy spectra after passing thick absorbers do not agree well with existing experimental data, as showed previously. Moreover, the spectra simulated for the Bethe-Bloch domain showed an unexpected sensitivity to the choice of low-energy electromagnetic models during the code execution. These observations were done with the GEANT4 version 8.2 during our simulations for pCT. This work describes in more details the simulations of the proton passage through aluminum absorbers with varied thickness. The simulations were done by modifying only the geometry in the Hadrontherapy Example, and for all available choices of the Electromagnetic Physics Models. As the most probable reasons for these effects is some specific feature in the code, or some specific implicit parameters in the GEANT4 manual, we continued our study with version 9.2 of the code. Some improvements in comparison with our previous results were obtained. The simulations were performed considering further applications for pCT development.

  4. Geant4 2005 10. user conference and collaboration workshop. Slides

    Energy Technology Data Exchange (ETDEWEB)

    Maire, M.; Amako, K.; Agapov, I.; Allison, J.; Amako, K.; Anah, J.; Apostolakis, J.; Asai, M.; Aso, T.; Barrand, G.; Becheva, E.; Berthoumieux, E.; Bongrand, M.; Boudard, A.; Canchel, G.; Capra, R.; Carlier, Th.; Chambon, P.; Chipaux, R.; Cognet, M.A.; Cornelius, I.; Cosmo, G.; Beenhouwer, J. de; Derreumaux, S.; Desbree, A.; Descourt, P.; Dridi, W.; Ersmark, T.; Faddegon, B.; Ferrer, L.; Flacco, A.; Folger, G.; Francis, S.; Giovinazzo, J.; Glinec, Y.; Godart, J.; Goncalves, P.; Gottschlag, H.; Grichine, V.; Guatelli, S.; Gudowska, I.; Guemnie Tafo, A.; Gueye, P.; Gumplinger, P.; Gurriaran, R.; Hannachi, F.; Heikkinen, A.; Hill, D.; Honore, P.F.; Howard, A.; Hrivnacova, I.; Hubert, X.; Incerti, S.; Ivanchenko, V.; Jacquemier, J.; Jones, F.; Kerhoas-Cavata, S.; Klem, J.; Koi, T.; Kosov, M.; Labalme, M.; Lang, N.; Lemercier, M.; Lemiere, Y.; Leroy, P.; Link, O.; Liu, B.; Lydon, J.; Maire, M.; Marchand, D.; Marquet, Ch.; Mascialino, B.; Matea, I.; Mccormick, J.; Mclaren, I.; Merchant, M.; Miceli, A.; Mine, Ph.; Moretto, Ph.; Mount, R.; Murakami, K.; Nachab, H.; Nehmeh, S.; Nieminen, P.; Paganetti, H.; Pallon, J.; Pandola, L.; Perl, J.; Perrot, F.; Pia Maria, G.; Piqueras, I.; Pouthier, Th.; Pshenichnov, I.; Raaijmakers, A.; Raaymakers, B.; Reuillon, R.; Ribon, A.; Rodrigues, P.; Rogel, G.; Salehzahi, F.; Santin, G.; Sasaki, T.; Schubert, M.; Seznec, H.; Shipley, D.; Skaza, F.; Thiam Cheick, O.; Tome, B.; Traneus, E.; Trindade, A.; Truscott, P.; Vacanti, G.; Verderi, M.; Watase, Y.; Wright, D.; Yarba, J.; Yoshida, H.; Zacharatou-Jarlskog, Ch.; Zhang, Q

    2005-07-01

    Originally developed for the simulation of large scale particle physics experiments, the field of applications of the conferences Geant4 is growing fast worldwide especially at the physics medicine biology frontier. In this framework the 2005 Geant4 conference was dedicated to simulations with a strong interest at the physics medicine biology frontier. In particular the following topics were discussed: review of simulation applications for medicine, validation of Geant4 models for medical physics, simulation of radiotherapy and irradiation setups, treatment planning in radiotherapy, dosimetry, parallelization, imaging techniques, data handling, related GRID developments and applications and the Geant4 DNA project with related Monte Carlo tools. Slides are provided. (A.L.B.)

  5. An Overview of the Geant4 Toolkit

    Science.gov (United States)

    Apostolakis, John; Wright, Dennis H.

    2007-03-01

    Geant4 is a toolkit for the simulation of the transport of radiation through matter. With a flexible kernel and choices between different physics modeling choices, it has been tailored to the requirements of a wide range of applications. With the toolkit a user can describe a setup's or detector's geometry and materials, navigate inside it, simulate the physical interactions using a choice of physics engines, underlying physics cross-sections and models, visualise and store results. Physics models describing electromagnetic and hadronic interactions are provided, as are decays and processes for optical photons. Several models, with different precision and performance are available for many processes. The toolkit includes coherent physics model configurations, which are called physics lists. Users can choose an existing physics list or create their own, depending on their requirements and the application area. A clear structure and readable code, enable the user to investigate the origin of physics results. Application areas include detector simulation and background simulation in High Energy Physics experiments, simulation of accelerator setups, studies in medical imaging and treatment, and the study of the effects of solar radiation on spacecraft instruments.

  6. Geant4 in Scientific Literature

    CERN Document Server

    Pia, M G; Bell, Z W; Dressendorfer, P V

    2009-01-01

    The Geant4 reference paper published in Nuclear Instruments and Methods A in 2003 has become the most cited publication in the whole Nuclear Science and Technology category of Thomson-Reuter's Journal Citation Reports. It is currently the second most cited article among the publications authored by two major research institutes, CERN and INFN. An overview of Geant4 presence (and absence) in scholarly literature is presented; the patterns of Geant4 citations are quantitatively examined and discussed.

  7. Experiences on Grid production for Geant4

    CERN Document Server

    Ribon, Alberto

    2006-01-01

    Geant4 is a general purpose toolkit for simulating the tracking and interaction of particles through matter. It is currently used in production in several particle physics experiments (BaBar, HARP, ATLAS, CMS, LHCb), and it has also applications in other areas, as space science, medical applications, and radiation studies. The complexity of the Geant4 code requires careful testing of all of its components, especially before major releases (which happens twice a year, in June and December). In this talk, I will describe the recent development of an automatic suite for testing hadronic physics in high energy calorimetry applications. The idea is to use a simplified set of hadronic calorimeters, with different beam particle types, and various beam energies, and comparing relevant observables between a given reference version of Geant4 and the new candidate one. Only those distributions that are statistically incompatible are then printed out and finally inspected by a person to look for possible bugs. The suite ...

  8. A CAD Interface for GEANT4

    CERN Document Server

    Poole, Christopher M; Trapp, Jamie V; Langton, Christian M

    2011-01-01

    Typically used as a tool for Monte Carlo simulation of high energy physics experiments, GEANT4 is increasingly being employed for the simulation of complex radiotherapy treatments. Often the specification of components within a clinical linear accelerator treatment head is provided in a CAD file format. Direct import of these CAD files into GEANT4 may not be possible, and complex components such as individual leaves within a multi-leaf collimator may be difficult to define via other means. Solutions that allow for users to work around the limited support in the GEANT4 toolkit for loading predefined CAD geometries has been presented by others, however these solutions require intermediate file format conversion using commercial software. Here within we describe a technique that allows for CAD models to be directly loaded as geometry without the need for commercial software and intermediate file format conversion. Robustness of the interface was tested using a set of CAD models of various complexity; for the mod...

  9. Allowing for crystalline structure effects in Geant4

    Science.gov (United States)

    Bagli, Enrico; Asai, Makoto; Dotti, Andrea; Pandola, Luciano; Verderi, Marc

    2017-07-01

    In recent years, the Geant4 toolkit for the Monte Carlo simulation of radiation with matter has seen large growth in its divers user community. A fundamental aspect of a successful physics experiment is the availability of a reliable and precise simulation code. Geant4 currently does not allow for the simulation of particle interactions with anything other than amorphous matter. To overcome this limitation, the GECO (GEant4 Crystal Objects) project developed a general framework for managing solid-state structures in the Geant4 kernel and validate it against experimental data. Accounting for detailed geometrical structures allows, for example, simulation of diffraction from crystal planes or the channeling of charged particle.

  10. Geant4 Applications in Space

    Energy Technology Data Exchange (ETDEWEB)

    Asai, M.; /SLAC

    2007-11-07

    Use of Geant4 is rapidly expanding in space application domain. I try to overview three major application areas of Geant4 in space, which are apparatus simulation for pre-launch design and post-launch analysis, planetary scale simulation for radiation spectra and surface and sub-surface explorations, and micro-dosimetry simulation for single event study and radiation-hardening of semiconductor devices. Recently, not only the mission dependent applications but also various multi-purpose or common tools built on top of Geant4 are also widely available. I overview some of such tools as well. The Geant4 Collaboration identifies that the space applications are now one of the major driving forces of the further developments and refinements of Geant4 toolkit. Highlights of such developments are introduced.

  11. Review of Geant4-DNA applications for micro and nanoscale simulations.

    Science.gov (United States)

    Incerti, S; Douglass, M; Penfold, S; Guatelli, S; Bezak, E

    2016-10-01

    Emerging radiotherapy treatments including targeted particle therapy, hadron therapy or radiosensitisation of cells by high-Z nanoparticles demand the theoretical determination of radiation track structure at the nanoscale. This is essential in order to evaluate radiation damage at the cellular and DNA level. Since 2007, Geant4 offers physics models to describe particle interactions in liquid water at the nanometre level through the Geant4-DNA Package. This package currently provides a complete set of models describing the event-by-event electromagnetic interactions of particles with liquid water, as well as developments for the modelling of water radiolysis. Since its release, Geant4-DNA has been adopted as an investigational tool in kV and MV external beam radiotherapy, hadron therapies using protons and heavy ions, targeted therapies and radiobiology studies. It has been benchmarked with respect to other track structure Monte Carlo codes and, where available, against reference experimental measurements. While Geant4-DNA physics models and radiolysis modelling functionalities have already been described in detail in the literature, this review paper summarises and discusses a selection of representative papers with the aim of providing an overview of a) geometrical descriptions of biological targets down to the DNA size, and b) the full spectrum of current micro- and nano-scale applications of Geant4-DNA.

  12. Beam Tools for Geant4 (User's Guide)

    CERN Document Server

    Daniel, E

    2002-01-01

    Geant4 is a tool kit developed by a collaboration of physicists and computer professionals in the high energy physics field for simulation of the passage of particles through matter. The motivation for the development of the Beam Tools is to extend the Geant4 applications to accelerator physics. The Beam Tools are a set of C++ classes designed to facilitate the simulation of accelerator elements: r.f. cavities, magnets, absorbers, etc. These elements are constructed from Geant4 solid volumes like boxes, tubes, trapezoids, or spheres. There are many computer programs for beam physics simulations, but Geant4 is ideal to model a beam through a material or to integrate a beam line with a complex detector. There are many such examples in the current international High Energy Physics programs. For instance, an essential part of the R and D associated with the Neutrino Source/Muon Collider accelerator is the ionization cooling channel, which is a section of the system aimed to reduce the size of the muon beam in pha...

  13. Geant4-DNA simulation of electron slowing-down spectra in liquid water

    Science.gov (United States)

    Incerti, S.; Kyriakou, I.; Tran, H. N.

    2017-04-01

    This work presents the simulation of monoenergetic electron slowing-down spectra in liquid water by the Geant4-DNA extension of the Geant4 Monte Carlo toolkit (release 10.2p01). These spectra are simulated for several incident energies using the most recent Geant4-DNA physics models, and they are compared to literature data. The influence of Auger electron production is discussed. For the first time, a dedicated Geant4-DNA example allowing such simulations is described and is provided to Geant4 users, allowing further verification of Geant4-DNA track structure simulation capabilities.

  14. Geant4-DNA simulation of electron slowing-down spectra in liquid water

    Energy Technology Data Exchange (ETDEWEB)

    Incerti, S., E-mail: sebastien.incerti@tdt.edu.vn [Division of Nuclear Physics, Ton Duc Thang University, Tan Phong Ward, District 7, Ho Chi Minh City (Viet Nam); Faculty of Applied Sciences, Ton Duc Thang University, Tan Phong Ward, District 7, Ho Chi Minh City (Viet Nam); Univ. Bordeaux, CENBG, UMR 5797, F-33170, Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); Kyriakou, I. [Medical Physics Laboratory, University of Ioannina Medical School, 45110 Ioannina (Greece); Tran, H.N. [Division of Nuclear Physics, Ton Duc Thang University, Tan Phong Ward, District 7, Ho Chi Minh City (Viet Nam); Faculty of Applied Sciences, Ton Duc Thang University, Tan Phong Ward, District 7, Ho Chi Minh City (Viet Nam)

    2017-04-15

    This work presents the simulation of monoenergetic electron slowing-down spectra in liquid water by the Geant4-DNA extension of the Geant4 Monte Carlo toolkit (release 10.2p01). These spectra are simulated for several incident energies using the most recent Geant4-DNA physics models, and they are compared to literature data. The influence of Auger electron production is discussed. For the first time, a dedicated Geant4-DNA example allowing such simulations is described and is provided to Geant4 users, allowing further verification of Geant4-DNA track structure simulation capabilities.

  15. GEANT4 for breast dosimetry: parameters optimization study.

    Science.gov (United States)

    Fedon, C; Longo, F; Mettivier, G; Longo, R

    2015-08-21

    Mean glandular dose (MGD) is the main dosimetric quantity in mammography. MGD evaluation is obtained by multiplying the entrance skin air kerma (ESAK) by normalized glandular dose (DgN) coefficients. While ESAK is an empirical quantity, DgN coefficients can only be estimated with Monte Carlo (MC) methods. Thus, a MC parameters benchmark is needed for effectively evaluating DgN coefficients. GEANT4 is a MC toolkit suitable for medical purposes that offers to the users several computational choices. In this work we investigate the GEANT4 performances testing the main PhysicsLists for medical applications. Four electromagnetic PhysicsLists were implemented: the linear attenuation coefficients were calculated for breast glandularity 0%, 50%, 100% in the energetic range 8-50 keV and DgN coefficients were evaluated. The results were compared with published data. Fit equations for the estimation of the G-factor parameter, introduced by the literature for converting the dose delivered in the heterogeneous medium to that in the glandular tissue, are proposed and the application of this parameter interaction-by-interaction or retrospectively is discussed. G4EmLivermorePhysicsList shows the best agreement for the linear attenuation coefficients both with theoretical values and published data. Moreover, excellent correlation factor (r2>0.99) is found for the DgN coefficients with the literature. The final goal of this study is to identify, for the first time, a benchmark of parameters that could be useful for future breast dosimetry studies with GEANT4.

  16. GEANT4 and CREME96 compare using only protons fluxes

    CERN Document Server

    Falzetta, Giuseppe; Zanini, Alba

    2007-01-01

    CREME96 and GEANT4 are two well known particles transport codes through matter. In this work, we present a comparison between the protons fluxes outgoing from an aluminium target, obtained by using both tools. The primary proton flux is obtained by CREME96 only and it is the same for both cases. We study different thickness targets and two different GEANT4 physics lists in order to show how the spectra of the outgoing proton fluxes are modified. Our results show good agreement of simulation data for both tools, for both GEANT4 physics lists and for every thickness target analysed.

  17. Polarised Geant4 - Applications at the ILC

    Energy Technology Data Exchange (ETDEWEB)

    Schaelicke, A. [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany); Laihem, K. [RWTH Aachen (Germany). III. Physikalisches Inst. B; Starovoitov, P. [NCPHEP BSU, Minsk (Belarus)

    2007-11-15

    Geant4 is a Monte Carlo simulation framework for the description of interactions of particles and matter. Starting with version 8.2 a new package of QED physics processes is available, allowing for the studies of interactions of polarised particles with polarised media dedicated to beam applications. In this contribution some details about the implementation are presented and applications to the linear collider are discussed. (orig.)

  18. Polarised Geant4 - Applications at the ILC

    OpenAIRE

    Schälicke, Andreas; Laihem, Karim; Starovoitov, Pavel

    2007-01-01

    Geant4 is a Monte Carlo simulation framework for the description of interactions of particles and matter. Starting with version 8.2 a new package of QED physics processes is available, allowing for the studies of interactions of polarised particles with polarised media dedicated to beam applications. In this contribution some details about the implementation are presented and applications to the linear collider are discussed.

  19. Detector Geometry Simulation Using GEANT4

    Directory of Open Access Journals (Sweden)

    Daisy Kalra

    2015-08-01

    Full Text Available Neutrino oscillation is an important phenomenon to explain the massive nature of neutrinos. This quantum mechanical phenomenon can be understood as mixing in quark sector just like the one we have in lepton sector. Observed deficit of solar neutrino flux is explained through neutrino oscillations and this study is the only way to investigate for small difference of neutrino masses thus gives signatures for the physics beyond Standard Model. Experimental results by Superkamiokande put a huge interest of experimentalists in neutrino field. In the present article after discussing the theoretical background of neutrinos and their status in standard model, latest important long baseline neutrino oscillations experiments as NOvA and LBNE has been discussed. Straw Tube Detector, an important part of LBNE-near detector, has been reviewed the geometry of which is studied through a software Geometry and Tracking (Geant4. Using Geant4, an important aspect of detector geometry and simulation has been studied.

  20. Recent Developments in the Geant4 Hadronic Framework

    Science.gov (United States)

    Pokorski, Witold; Ribon, Alberto

    2014-06-01

    In this paper we present the recent developments in the Geant4 hadronic framework. Geant4 is the main simulation toolkit used by the LHC experiments and therefore a lot of effort is put into improving the physics models in order for them to have more predictive power. As a consequence, the code complexity increases, which requires constant improvement and optimization on the programming side. At the same time, we would like to review and eventually reduce the complexity of the hadronic software framework. As an example, a factory design pattern has been applied in Geant4 to avoid duplications of objects, like cross sections, which can be used by several processes or physics models. This approach has been applied also for physics lists, to provide a flexible configuration mechanism at run-time, based on macro files. Moreover, these developments open the future possibility to build Geant4 with only a specified sub-set of physics models. Another technical development focused on the reproducibility of the simulation, i.e. the possibility to repeat an event once the random generator status at the beginning of the event is known. This is crucial for debugging rare situations that may occur after long simulations. Moreover, reproducibility in normal, sequential Geant4 simulation is an important prerequisite to verify the equivalence with multithreaded Geant4 simulations.

  1. New techniques in Monte Carlo simulation: experience with a prototype of generic programming application to Geant4 physics processes

    CERN Document Server

    Pia, Maria Grazia; Begalli, Marcia; Quintieri, Lina; Saracco, Paolo; Sudhakar, Manju; Weidenspointner, Georg; Zoglauer, Andreas

    2010-01-01

    An investigation is in progress to evaluate extensively and quantitatively the possible benefits and drawbacks of new programming paradigms in a Monte Carlo simulation environment, namely in the domain of physics modeling. The prototype design and extensive benchmarks, including a variety of rigorous quantitative metrics, are presented. The results of this research project allow the evaluation of new software techniques for their possible adoption in Monte Carlo simulation on objective, quantitative ground.

  2. Nuclear spectroscopy with Geant4. The superheavy challenge

    Science.gov (United States)

    Sarmiento, Luis G.

    2016-12-01

    The simulation toolkit Geant4 was originally developed at CERN for high-energy physics. Over the years it has been established as a swiss army knife not only in particle physics but it has seen an accelerated expansion towards nuclear physics and more recently to medical imaging and γ- and ion- therapy to mention but a handful of new applications. The validity of Geant4 is vast and large across many particles, ions, materials, and physical processes with typically various different models to choose from. Unfortunately, atomic nuclei with atomic number Z > 100 are not properly supported. This is likely due to the rather novelty of the field, its comparably small user base, and scarce evaluated experimental data. To circumvent this situation different workarounds have been used over the years. In this work the simulation toolkit Geant4 will be introduced with its different components and the effort to bring the software to the heavy and superheavy region will be described.

  3. Quantitative Test of the Evolution of Geant4 Electron Backscattering Simulation

    CERN Document Server

    Basaglia, Tullio; Hoff, Gabriela; Kim, Chan Hyeong; Kim, Sung Hun; Pia, Maria Grazia; Saracco, Paolo

    2016-01-01

    Evolutions of Geant4 code have affected the simulation of electron backscattering with respect to previously published results. Their effects are quantified by analyzing the compatibility of the simulated electron backscattering fraction with a large collection of experimental data for a wide set of physics configuration options available in Geant4. Special emphasis is placed on two electron scattering implementations first released in Geant4 version 10.2: the Goudsmit-Saunderson multiple scattering model and a single Coulomb scattering model based on Mott cross section calculation. The new Goudsmit-Saunderson multiple scattering model appears to perform equally or less accurately than the model implemented in previous Geant4 versions, depending on the electron energy. The new Coulomb scattering model was flawed from a physics point of view, but computationally fast in Geant4 version 10.2; the physics correction released in Geant4 version 10.2p01 severely degrades its computational performance. Evolutions in ...

  4. GEANT4 Simulation of the NPDGamma Experiment

    Science.gov (United States)

    Frlez, Emil

    2014-03-01

    The n-> + p --> d + γ experiment, currently taking data at the Oak Ridge SNS facility, is a high-precision measurement of weak nuclear forces at low energies. Detecting the correlation between the cold neutron spin and photon direction in the capture of neutrons on Liquid Hydrogen (LH) target, the experiment is sensitive to the properties of neutral weak current. We have written a GEANT4 Monte Carlo simulation of the NPDGamma detector that, in addition to the active CsI detectors, also includes different targets and passive materials as well as the beam line elements. The neutron beam energy spectrum, its profiles, divergencies, and time-of-flight are simulated in detail. We have used the code to cross-calibrate the positions of (i) polarized LH target, (ii) Aluminum target, and (iii) CCl4 target. The responses of the 48 CsI detectors in the simulation were fixed using data taken on the LH target. Both neutron absorption as well as scattering and thermal processes were turned on in the GEANT4 physics lists. We use the results to simulate in detail the data obtained with different targets used in the experiment within a comprehensive analysis. This work is supported by NSF grant PHY-1307328.

  5. Visualization drivers for Geant4

    Energy Technology Data Exchange (ETDEWEB)

    Beretvas, Andy; /Fermilab

    2005-10-01

    This document is on Geant4 visualization tools (drivers), evaluating pros and cons of each option, including recommendations on which tools to support at Fermilab for different applications. Four visualization drivers are evaluated. They are OpenGL, HepRep, DAWN and VRML. They all have good features, OpenGL provides graphic output without an intermediate file. HepRep provides menus to assist the user. DAWN provides high quality plots and even for large files produces output quickly. VRML uses the smallest disk space for intermediate files. Large experiments at Fermilab will want to write their own display. They should proceed to make this display graphics independent. Medium experiment will probably want to use HepRep because of it's menu support. Smaller scale experiments will want to use OpenGL in the spirit of having immediate response, good quality output and keeping things simple.

  6. The comparison of GEANT 4.8.2 and 4.9.2 results for the 25MeV protons in thick polyethylene

    Energy Technology Data Exchange (ETDEWEB)

    Yevseyeva, Olga; Assis, Joaquim T. de; Ievsieieva, Ievgeniia [Universidade Estadual do Rio de Janeiro (UERJ), Nova Friburgo, RJ (Brazil). Instituto Politecnico; Evseev, Ivan G.; Schelin, Hugo R.; Ahmann, Francielle; Paschuk, Sergei A.; Milhoretto, Edney [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil); Diaz, Katherin S. [Centro de Aplicaciones Tecnologicas y Desarrollo Nuclear, Havana (Cuba); Hormaza, Joel M. [Universidade Estadual Paulista (UNESP), Botucatu, SP (Brazil). Instituto de Biociencias; Lopes, Ricardo T. [Coordenacao dos Programas de Pos-Graduacao de Engenharia (COPPE/UFRJ), RJ (Brazil). Lab. de Instrumentacao Nuclear

    2011-07-01

    Full text: The fidelity of Monte Carlo simulations is crucial, especially if for medical applications. Our earlier study has shown that the GEANT4 simulations of proton energy spectra after thick absorbers do not agree well with existing experimental data. Moreover, the spectra simulated for the Bethe-Bloch domain were showing an unexpected sensitivity to the choice of low-energy electromagnetic models during the code execution. These observations were done with the GEANT4 up to version 8.2 during our previous simulations for proton Computerized Tomography (pCT). As one of the probable reasons for these effects could be some specific feature in the code, or some specific implicit parameters in the GEANT4 manual, we have decided to continue our observations, but this time - with version 4.9.2 of the GEANT. This work describes in details the new simulations for 25 MeV protons passing through 6mm polyethylene absorber. As in our previous simulations, we have started from the Hadron therapy Example of GEANT4 official release by adjusting the geometry only. We have tested all available choices of the Electromagnetic Physics Models. The results are compared with our previous GEANT4, TRIM/SRIM and MCNPX simulations, with theoretical predictions and with experimental data. Some variations in comparison with our previous results were obtained. (author)

  7. Validation of the Geant4 simulation of bremsstrahlung from thick targets below 3 MeV

    CERN Document Server

    Pandola, Luciano; Caccia, Barbara

    2014-01-01

    The bremsstrahlung spectra produced by electrons impinging on thick targets are simulated using the Geant4 Monte Carlo toolkit. Simulations are validated against experimental data available in literature for a range of energy between 0.5 and 2.8 MeV for Al and Fe targets and for a value of energy of 70 keV for Al, Ag, W and Pb targets. All three independent sets of electromagnetic models available in Geant4 to simulate bremsstrahlung are tested. A quantitative analysis is performed reproducing with each model the energy spectrum for the different configurations of emission angles, energies and targets. At higher energies (0.5-2.8 MeV) of the impinging electrons on Al and Fe targets, Geant4 is able to reproduce the spectral shapes and the integral photon emission in the forward direction (at better than 10%). The physics model based on the Penelope Monte Carlo code seems slightly preferable over the other two. However, all models over-estimate the photon emission in the backward hemisphere. For the lower energ...

  8. Geant4 simulations for the TOTEM upgrade program

    CERN Document Server

    Nemes, F

    2013-01-01

    The TOTEM physics goals require the installation of new cylindrical shaped Roman Pots, which are radiofrequency optimized and are able to house timing detectors. The topic of this analysis note is to study the secondary production of the standard box and the new cylindrical shaped Roman Pots. The studies and the results are based on Geant4 simulations.

  9. Comparison of experimental proton-induced fluorescence spectra for a selection of thin high-Z samples with Geant4 Monte Carlo simulations

    Energy Technology Data Exchange (ETDEWEB)

    Incerti, S., E-mail: sebastien.incerti@tdt.edu.vn [Division of Nuclear Physics, Ton Duc Thang University, Ho Chi Minh City (Viet Nam); Faculty of Applied Sciences, Ton Duc Thang University, Ho Chi Minh City (Viet Nam); Univ. Bordeaux, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); Barberet, Ph.; Dévès, G.; Michelet, C. [Univ. Bordeaux, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); Francis, Z. [Université Saint Joseph, Science Faculty, Department of Physics, Beirut (Lebanon); Ivantchenko, V. [Ecoanalytica, Moscow (Russian Federation); Geant4 Associates International Ltd, Hebden Bridge (United Kingdom); Mantero, A. [SWHARD srl, via Greto di Cornigliano 6r, 16152 Genova (Italy); El Bitar, Z. [Institut Pluridisciplinaire Hubert Curien, CNRS/IN2P3, 67037 Strasbourg Cedex (France); Bernal, M.A. [Instituto de Física Gleb Wataghin, Universidade Estadual de Campinas, SP (Brazil); Tran, H.N. [Division of Nuclear Physics, Ton Duc Thang University, Ho Chi Minh City (Viet Nam); Faculty of Applied Sciences, Ton Duc Thang University, Ho Chi Minh City (Viet Nam); Karamitros, M.; Seznec, H. [Univ. Bordeaux, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France)

    2015-09-01

    The general purpose Geant4 Monte Carlo simulation toolkit is able to simulate radiative and non-radiative atomic de-excitation processes such as fluorescence and Auger electron emission, occurring after interaction of incident ionising radiation with target atomic electrons. In this paper, we evaluate the Geant4 modelling capability for the simulation of fluorescence spectra induced by 1.5 MeV proton irradiation of thin high-Z foils (Fe, GdF{sub 3}, Pt, Au) with potential interest for nanotechnologies and life sciences. Simulation results are compared to measurements performed at the Centre d’Etudes Nucléaires de Bordeaux-Gradignan AIFIRA nanobeam line irradiation facility in France. Simulation and experimental conditions are described and the influence of Geant4 electromagnetic physics models is discussed.

  10. Geant4 application in a Web browser

    Science.gov (United States)

    Garnier, Laurent; Geant4 Collaboration

    2014-06-01

    Geant4 is a toolkit for the simulation of the passage of particles through matter. The Geant4 visualization system supports many drivers including OpenGL[1], OpenInventor, HepRep[2], DAWN[3], VRML, RayTracer, gMocren[4] and ASCIITree, with diverse and complementary functionalities. Web applications have an increasing role in our work, and thanks to emerging frameworks such as Wt [5], building a web application on top of a C++ application without rewriting all the code can be done. Because the Geant4 toolkit's visualization and user interface modules are well decoupled from the rest of Geant4, it is straightforward to adapt these modules to render in a web application instead of a computer's native window manager. The API of the Wt framework closely matches that of Qt [6], our experience in building Qt driver will benefit for Wt driver. Porting a Geant4 application to a web application is easy, and with minimal effort, Geant4 users can replicate this process to share their own Geant4 applications in a web browser.

  11. Geant4 simulations of the lead fluoride calorimeter

    CERN Document Server

    Savchenko, A A; Dabagov, S B; Anastasi, A; Venanzoni, G; Strikhanov, M N

    2016-01-01

    In this paper we simulate the emission by charged particles in complex structures with help of Geant4. We take into account Cherenkov radiation, transition radiation, bremsstrahlung, pair production and other accompanying processes. As an application we investigate the full size electromagnetic calorimeter for the muon g-2 experiment at Fermilab. A calorimeter module (24 are expected in the experiment) consists of a Delrin front panel for installation of the laser calibration system, 54 PbF2 Cherenkov crystals wrapped by the black Millipore paper, and silicon photo-multiplier sensors. We report here on a simulation of radiation from positrons passing through the calorimeter system. We carry out the simulation using Geant4 toolkit, which provides a complete set of tools for all areas of detector simulation: geometry, tracking, detector response, run, event and track management, and visualization. We consider Cherenkov photons expansion when a positron moves down through the calorimeter at the arbitrary angle o...

  12. Recent improvements on the description of hadronic interactions in Geant4

    Science.gov (United States)

    Dotti, A.; Apostolakis, J.; Folger, G.; Grichine, V.; Ivanchenko, V.; Kosov, M.; Ribon, A.; Uzhinsky, V.; Wright, D. H.

    2011-04-01

    We present an overview of recent improvements of hadronic models in Geant4 for the physics configurations (Physics Lists) relevant to applications in high energy experiments. During last year the improvements have concentrated on the study of unphysical discontinuities in calorimeter observables in the transition regions between the models used in Physics Lists. The microscopic origin of these have been investigated, and possible improvements of Geant4 code are currently under validation. In this paper we discuss the status of the latest version of Geant4 with emphasis on the most promising new developments, namely the Fritiof based and CHIPS Physics Lists.

  13. GEANT 4.8.2, 9.2 and 9.4 simulations versus experimental proton energy loss in thick absorbers

    Energy Technology Data Exchange (ETDEWEB)

    Evseev, Ivan; Schelin, Hugo R.; Ahmann, Francielle; Milhoretto, Edney; Paschuk, Sergei A., E-mail: evseev@utfpr.edu.b, E-mail: schelin@utfpr.edu.b, E-mail: sergei@utfpr.edu.b [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil); Yevseyeva, Olga; Assis, Joaquim T. de; Ievsieieva, Ievgeniia, E-mail: yevseveva@iprj.uerj.b, E-mail: joaquim@iprj.uerj.b [Instituto Politecnico do Rio de Janeiro (IPRJ/UERJ), Nova Friburgo, RJ (Brazil). Dept. de Modelagem Computacional; Hormaza, Joel M., E-mail: jmesa@ibb.unesp.b [Universidade Estadual Paulista (IBB/UNESP), Botucatu, SP (Brazil). Inst. de Biociencias; Diaz, Katherin S. [Centro de Aplicaciones Tecnologicas y Desarrollo Nuclear, Havana (Cuba); Lopes, Ricardo T. [Coordenacao dos Programas de Pos-Graduacao de Engenharia (LIN/COPPE/UFRJ), RJ (Brazil). Lab. de Instrumentacao Nuclear

    2011-07-01

    Monte Carlo simulations are a powerful tool to estimate the proton energy loss and straggling in medical applications. The physics of proton interaction with matter for thick absorbers (like a human body) has a well-established theory for the so-called Bethe-Bloch domain, and the basic principles of Monte Carlo simulation for such processes are well known since the middle of the past century. However, in spite of GEANT4 has been validated against proton stopping powers from the NIST PSTAR, the evolution of the code leads to some result instability within the various code releases. In this work, we present the recent results for the comparison of our GEANT4 simulations against experimental proton energy loss for some thick absorbers. All the simulations were performed using the GEANT4 Hadrontherapy Advanced Example. The GEANT4 versions 4.8.2, 4.9.2, and 4.9.4 were tested with different simulation parameters, such as varied cut values. In addition to the Standard model, some other models for the electromagnetic processes from the GEANT4 Low Energy Extension Pack were tested as well. Experimental data were taken from for polyethylene, and from for aluminum and gold absorbers. The theoretical predictions for the spectra were calculated using the self-consistent Gaussian solution of the Boltzmann kinetic equation in the Fokker-Plank form. In order to compare the GEANT4 simulations with other popular codes, the same spectra were simulated by TRIM/SRIM2011 and MCNPX2.4.0. The simultaneous comparison of the results obtained for different materials at various initial proton energies were done using the reduced calibration curve approach. (author)

  14. Validation of the GEANT4 simulation of bremsstrahlung from thick targets below 3 MeV

    Science.gov (United States)

    Pandola, L.; Andenna, C.; Caccia, B.

    2015-05-01

    The bremsstrahlung spectra produced by electrons impinging on thick targets are simulated using the GEANT4 Monte Carlo toolkit. Simulations are validated against experimental data available in literature for a range of energy between 0.5 and 2.8 MeV for Al and Fe targets and for a value of energy of 70 keV for Al, Ag, W and Pb targets. The energy spectra for the different configurations of emission angles, energies and targets are considered. Simulations are performed by using the three alternative sets of electromagnetic models that are available in GEANT4 to describe bremsstrahlung. At higher energies (0.5-2.8 MeV) of the impinging electrons on Al and Fe targets, GEANT4 is able to reproduce the spectral shapes and the integral photon emission in the forward direction. The agreement is within 10-30%, depending on energy, emission angle and target material. The physics model based on the Penelope Monte Carlo code is in slightly better agreement with the measured data than the other two. However, all models over-estimate the photon emission in the backward hemisphere. For the lower energy study (70 keV), which includes higher-Z targets, all models systematically under-estimate the total photon yield, providing agreement between 10% and 50%. The results of this work are of potential interest for medical physics applications, where knowledge of the energy spectra and angular distributions of photons is needed for accurate dose calculations with Monte Carlo and other fluence-based methods.

  15. Inter-Comparison and Validation of Geant4 Photon Interaction Models

    CERN Document Server

    Augelli, M; Pia, M G; Queiroz, P P; Quintieri, L; Souza-Santos, D; Sudhakar, M; Saracco, P; Weidenspointner, G; Zoglauer, A

    2009-01-01

    A R&D project, named Nano5, has been recently launched to study an architectural design in view of addressing new experimental issues related to particle transport in high energy physics and other related physics disciplines with Geant4. In this frame, the first step has involved the redesign of the photon interaction models currently available in Geant4; this task has motivated a thorough investigation of the physics and computational features of these models, whose first results are presented here.

  16. Geant4 VMC 3.0

    Science.gov (United States)

    Hřivnáčová, I.; Gheata, A.

    2015-12-01

    Virtual Monte Carlo (VMC) [1] provides an abstract interface into Monte Carlo transport codes. A user VMC based application, independent from the specific Monte Carlo codes, can be then run with any of the supported simulation programs. Developed by the ALICE Offline Project and further included in ROOT [2], the interface and implementations have reached stability during the last decade and have become a foundation for other detector simulation frameworks, the FAIR facility experiments framework being among the first and largest. Geant4 VMC [3], which provides the implementation of the VMC interface for Geant4 [4], is in continuous maintenance and development, driven by the evolution of Geant4 on one side and requirements from users on the other side. Besides the implementation of the VMC interface, Geant4 VMC also provides a set of examples that demonstrate the use of VMC to new users and also serve for testing purposes. Since major release 2.0, it includes the G4Root navigator package, which implements an interface that allows one to run a Geant4 simulation using a ROOT geometry. The release of Geant4 version 10.00 with the integration of multithreading processing has triggered the development of the next major version of Geant4 VMC (version 3.0), which was released in November 2014. A beta version, available for user testing since March, has helped its consolidation and improvement. We will review the new capabilities introduced in this major version, in particular the integration of multithreading into the VMC design, its impact on the Geant4 VMC and G4Root packages, and the introduction of a new package, MTRoot, providing utility functions for ROOT parallel output in independent files with necessary additions for thread-safety. Migration of user applications to multithreading that preserves the ease of use of VMC will be also discussed. We will also report on the introduction of a new CMake [5] based build system, the migration to ROOT major release 6 and the

  17. Foil Diffuser Investigation with GEANT4

    CERN Document Server

    Fabritius, Joseph M; Walstrom, Peter

    2013-01-01

    An investigation into the appropriate materials for use as a diffuser foil in electron radiography was undertaken in GEANT4. Simulations were run using various refractory materials to determine a material of appropriate Z number such that energy loss is minimal. The plotted results of angular spread and energy spread are shown. It is concluded that higher Z number materials such as tungsten, tantalum, platinum or uranium could be used as diffuser materials. Also, an investigation into the handling of bremsstrahlung, multiple coulomb scattering, and ionization in GEANT4 was performed.

  18. Monte Carlo method studies and a comparative between GEANT4 tool kit and MCNPX to depth dose in medical physics; Estudos do metodo Monte Carlo e um comparativo entre a ferramenta GEANT4 e MCNPX para doses profundas em fisica medica

    Energy Technology Data Exchange (ETDEWEB)

    Magalhaes, Antonio H.M.; Lemke, Ney; Hormaza, Joel M.; Silva, Danilo A. da; Inocente, Guilherme F.; Pazianotto, Mauricio T., E-mail: ahmmagalhaes@gmail.co [UNESP, Botucatu, SP (Brazil). Inst. de Biociencias. Dept. de Fisica e Biofisica

    2009-07-01

    Knowing the depth dose at the central axis is fundamental for the accurate planning of medical treatment systems involving ionizing radiation. With the evolution of the informatics it is possible the utilization of various computational tools such as GEANT4 and the MCNPX, which use the Monte Carlo Method for simulation of such situations, This paper makes a comparative between the two tools for the this type of application

  19. Geant4 VMC 3.0

    CERN Document Server

    Hřivnáčová, I

    2015-01-01

    Virtual Monte Carlo (VMC) [1] provides an abstract interface into Monte Carlo transport codes. A user VMC based application, independent from the specific Monte Carlo codes, can be then run with any of the supported simulation programs. Developed by the ALICE Offline Project and further included in ROOT [2], the interface and implementations have reached stability during the last decade and have become a foundation for other detector simulation frameworks, the FAIR facility experiments framework being among the first and largest.Geant4 VMC [3], which provides the implementation of the VMC interface for Geant4 [4], is in continuous maintenance and development, driven by the evolution of Geant4 on one side and requirements from users on the other side. Besides the implementation of the VMC interface, Geant4 VMC also provides a set of examples that demonstrate the use of VMC to new users and also serve for testing purposes. Since major release 2.0, it includes the G4Root navigator package, which implements an in...

  20. GEANT4, the physicists simulation toolkit

    CERN Multimedia

    Perricone, Mike

    2005-01-01

    One of the biggest projects ever mounted in science: the development of the proposed International Linear Collider; serving as combination instruction manual/toolkit/support network is GEANT4, a freely-available software ackage that simulates the passage of particles through scientific instruments (2 pages)

  1. GEANT 4: an Object-Oriented toolkit for simulation in HEP

    CERN Multimedia

    Kent, P; Sirotenko, V; Komogorov, M; Pavliouk, A; Greeniaus, G L; Kayal, P I; Routenburg, P; Tanaka, S; Duellmann, D; Innocente, V; Paoli, S; Ranjard, F; Riccardi, F; Ruggier, M; Shiers, J; Egli, S; Kimura, A; Urban, P; Prior, S; Walkden, A; Forti, A; Magni, S; Strahl, K; Kokoulin, R; Braune, K; Volcker, C; Ullrich, T; Takahata, M; Nieminen, P; Ballocchi, G; Mora De Freitas, P; Verderi, M; Rybine, A; Langeveld, W; Nagamatsu, M; Hamatsu, R; Katayama, N; Chuma, J; Felawka, L; Gumplinger, P; Axen, D

    2002-01-01

    %RD44 %title\\\\ \\\\The GEANT4 software has been developed by a world-wide collaboration of about 100 scientists from over 40 institutions and laboratories participating in more than 10 experiments in Europe, Russia, Japan, Canada, and the United States. The GEANT4 detector simulation toolkit has been designed for the next generation of High Energy Physics (HEP) experiments, with primary requirements from the LHC, the CP violation, and the heavy ions experiments. In addition, GEANT4 also meets the requirements from the space and medical communities, thanks to very low energy extensions developed in a joint project with the European Space Agency (ESA). GEANT4 has exploited advanced software engineering techniques (for example PSS-05) and Object-Oriented technology to improve the validation process of the physics results, and in the same time to make possible the distributed software design and development in the world-wide collaboration. Fifteen specialised working groups have been responsible for fields as diver...

  2. Experiences in the Gridification of the Geant4 Toolkit in the WLCG/EGEE Environment

    CERN Document Server

    Mendez-Lorenzo, R; Ribon, A

    2007-01-01

    The general patterns observed in supporting the Geant4 application in the EGEE infrastructure are discussed. Regression testing of Geant4 public releases is in the focus of this paper. Geant4 is a toolkit for the Monte Carlo simulation of the interaction of particle with matter, used by a wide field of research, including high energy and nuclear physics and also medical, accelerator and space physics studies. The support required for the release regression testing of Geant4 toolkit, including setting up of the new, official Virtual Organization in the EGEE, is explained. Recent developments of automatic regression testing suites and the benefits of the optimization layer above the standard Grid infrastructure are presented.

  3. Scalable Parallel Implementation of GEANT4 Using Commodity Hardware and Task Oriented Parallel C

    CERN Document Server

    Cooperman, G; Grinberg, V; McCauley, T; Reucroft, S; Swain, J D; Cooperman, Gene; Anchordoqui, Luis; Grinberg, Victor; Cauley, Thomas Mc; Reucroft, Stephen; Swain, John

    2000-01-01

    We describe a scalable parallelization of Geant4 using commodity hardware in a collaborative effort between the College of Computer Science and the Department of Physics at Northeastern University. The system consists of a Beowulf cluster of 32 Pentium II processors with 128 MBytes of memory each, connected via ATM and fast Ethernet. The bulk of the parallelization is done using TOP-C (Task Oriented Parallel C), software widely used in the computational algebra community. TOP-C provides a flexible and powerful framework for parallel algorithm development, is easy to learn, and is available at no cost. Its task oriented nature allows one to parallelize legacy code while hiding the details of interprocess communications. Applications include fast interactive simulation of computationally intensive processes such as electromagnetic showers. General results motivate wider applications of TOP-C to other simulation problems as well as to pattern recognition in high energy physics.

  4. Implementation of mathematical phantom of hand and forearm in GEANT4 Monte Carlo code; Implementacao de fantoma matematico de mao e antebraco em codigo Monte Carlo GEANT4

    Energy Technology Data Exchange (ETDEWEB)

    Pessanha, Paula Rocha; Queiroz Filho, Pedro Pacheco de; Santos, Denison de Souza, E-mail: pessanha.paular@gmail.com, E-mail: queiroz@ird.gov.br, E-mail: santosd@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ),Rio de Janeiro, RJ (Brazil)

    2014-07-01

    In this work, the implementation of a hand and forearm Geant4 phantom code, for further evaluation of occupational exposure of ends of the radionuclides decay manipulated during procedures involving the use of injection syringe. The simulation model offered by Geant4 includes a full set of features, with the reconstruction of trajectories, geometries and physical models. For this work, the values calculated in the simulation are compared with the measurements rates by thermoluminescent dosimeters (TLDs) in physical phantom REMAB®. From the analysis of the data obtained through simulation and experimentation, of the 14 points studied, there was a discrepancy of only 8.2% of kerma values found, and these figures are considered compatible. The geometric phantom implemented in Geant4 Monte Carlo code was validated and can be used later for the evaluation of doses at ends.

  5. The application of Geant4 simulation code for brachytherapy treatment

    CERN Document Server

    Agostinelli, S; Garelli, S; Paoli, G; Nieminen, P; Pia, M G

    2000-01-01

    Brachytherapy is a radiotherapeutic modality that makes use of radionuclides to deliver a high radiation dose to a well-defined volume while sparing surrounding healthy structures. At the National Institute for Cancer Research of Genova a High Dose Rate remote afterloading system provides Ir(192) endocavitary brachytherapy treatments. We studied the possibility to use the Geant4 Monte Carlo simulation toolkit in brachytherapy for calculation of complex physical parameters, not directly available by experiment al measurements, used in treatment planning dose deposition models.

  6. Geant4 and Fano cavity test: where are we?

    CERN Document Server

    Elles, S; Maire, M; Urbàn, L

    2008-01-01

    The electron transport algorithm implemented in Geant4 has been recently revised. The modifications concern several physics aspects of the simulation model: the step limitation, the energy loss along a step and the multiple scattering. The Fano cavity setup was used to test these developments. The upgrades increase significantly the accuracy of the electron transport simulation. The ratio of simulated to theoretical dose deposition in the cavity is stable to ~1% while varying several parameters and within ~1.5% of the expected value for water and graphite. Work is underway to identify and resolve the remaining shift.

  7. Geant4 - Towards major release 10

    Science.gov (United States)

    Cosmo, G.; Geant4 Collaboration

    2014-06-01

    The Geant4 simulation toolkit has reached maturity in the middle of the previous decade, providing a wide variety of established features coherently aggregated in a software product, which has become the standard for detector simulation in HEP and is used in a variety of other application domains. We review the most recent capabilities introduced in the kernel, highlighting those, which are being prepared for the next major release (version 10.0) that is scheduled for the end of 2013. A significant new feature contained in this release will be the integration of multi-threading processing, aiming at targeting efficient use of modern many-cores system architectures and minimization of the memory footprint for exploiting event-level parallelism. We discuss its design features and impact on the existing API and user-interface of Geant4. Revisions are made to balance the need for preserving backwards compatibility and to consolidate and improve the interfaces; taking into account requirements from the multithreaded extensions and from the evolution of the data processing models of the LHC experiments.

  8. Microdosimetry calculations for monoenergetic electrons using Geant4-DNA combined with a weighted track sampling algorithm

    Science.gov (United States)

    Famulari, Gabriel; Pater, Piotr; Enger, Shirin A.

    2017-07-01

    The aim of this study was to calculate microdosimetric distributions for low energy electrons simulated using the Monte Carlo track structure code Geant4-DNA. Tracks for monoenergetic electrons with kinetic energies ranging from 100 eV to 1 MeV were simulated in an infinite spherical water phantom using the Geant4-DNA extension included in Geant4 toolkit version 10.2 (patch 02). The microdosimetric distributions were obtained through random sampling of transfer points and overlaying scoring volumes within the associated volume of the tracks. Relative frequency distributions of energy deposition f(>E)/f(>0) and dose mean lineal energy (\\bar{y}D ) values were calculated in nanometer-sized spherical and cylindrical targets. The effects of scoring volume and scoring techniques were examined. The results were compared with published data generated using MOCA8B and KURBUC. Geant4-DNA produces a lower frequency of higher energy deposits than MOCA8B. The \\bar{y}D values calculated with Geant4-DNA are smaller than those calculated using MOCA8B and KURBUC. The differences are mainly due to the lower ionization and excitation cross sections of Geant4-DNA for low energy electrons. To a lesser extent, discrepancies can also be attributed to the implementation in this study of a new and fast scoring technique that differs from that used in previous studies. For the same mean chord length (\\bar{l} ), the \\bar{y}D calculated in cylindrical volumes are larger than those calculated in spherical volumes. The discrepancies due to cross sections and scoring geometries increase with decreasing scoring site dimensions. A new set of \\bar{y}D values has been presented for monoenergetic electrons using a fast track sampling algorithm and the most recent physics models implemented in Geant4-DNA. This dataset can be combined with primary electron spectra to predict the radiation quality of photon and electron beams.

  9. Validation of Geant4 Hadronic Generators versus Thin Target Data

    Energy Technology Data Exchange (ETDEWEB)

    Banerjee, S.; /Fermilab; Folger, G.; /CERN; Ivanchenko, A.; /CERN /CENBG, Gradignan; Ivanchenko, V.N.; /CERN /NeurOK, Moscow /Metz U.; Kossov, M.; /CERN; Quesada, J.M.; /Seville U.; Schalicke, A.; /DESY, Zeuthen; Uzhinsky, V.; /CERN; Wenzel, H.; /Fermilab; Wright, D.H.; /SLAC; Yarba, J.; /Fermilab

    2012-04-19

    The GEANT4 toolkit is widely used for simulation of high energy physics (HEP) experiments, in particular, those at the Large Hadron Collider (LHC). The requirements of robustness, stability and quality of simulation for the LHC are demanding. This requires an accurate description of hadronic interactions for a wide range of targets over a large energy range, from stopped particle reactions to low energy nuclear interactions to interactions at the TeV energy scale. This is achieved within the Geant4 toolkit by combining a number of models, each of which are valid within a certain energy domain. Comparison of these models to thin target data over a large energy range indicates the strengths and weaknesses of the model descriptions and the energy range over which each model is valid. Software has been developed to handle the large number of validation tests required to provide the feedback needed to improve the models. An automated process for carrying out the validation and storing/displaying the results is being developed and will be discussed.

  10. Geant4 - Current and Future : A Snowmass 2013 White Paper

    CERN Document Server

    Asai, Makoto

    2013-01-01

    The US involvement in Geant4 started with its adoption by the BaBar experiment at SLAC in 1997 and the subsequent creation of a group at SLAC supporting BaBar and contributing to Geant4 development. SLAC has provided the leadership of the international Geant4 Collaboration for the recent years and carries major responsibilities for evolutionary development of the existing code with work to implement multithreading and explore new application domains as well as new technologies such as GPUs. This paper presents the current and the future developments being carried by the SLAC Geant4 team.

  11. Particle physics software aids space and medicine

    CERN Document Server

    Pia, M G

    2002-01-01

    Geant4 is a showcase example of technology transfer from particle physics to other fields such as space and medical science. Geant4 was first used for space applications by ESA in 1999, when ESA and NASA each launched an X-ray telescope. Geant4's extended set of physics models, which handle both electromagnetic and hadronic interactions, can be used to address a range of medical applications from conventional photon-beam radiotherapy to brachytherapy (using radioactive sources), hadron therapy and boron neutron capture therapy. The tools for describing geometries, materials and electromagnetic fields can precisely model diverse real-life configurations.

  12. GEANT4 simulation of gamma ray in a double-gap resistive plate chamber

    Institute of Scientific and Technical Information of China (English)

    J. T. Rhee; M. Jamil; Steve Hall; Y. J. Jeon

    2006-01-01

    For more than 20 years nuclear physicists have used the GEANT code to simulate particle-matter interaction. In most recent version, GEANT4 is a toolkit for simulating the passage of particles though matter, which contains a complete range of functionality including tracking, geometry, physics models, and hits. In this article, an attempt to use GEANT4 to model a double-gap resistive plate chamber (RFC) with its improved efficiency is presented. The efficiencies of the double-gap RFC have been evaluated as a function of gamma energy range 0.005-1OOOMeV. A comparison to available previous simulation package GEANT3 data is also performed.

  13. Modeling the relativistic runaway electron avalanche and the feedback mechanism with GEANT4

    Science.gov (United States)

    Skeltved, Alexander Broberg; Østgaard, Nikolai; Carlson, Brant; Gjesteland, Thomas; Celestin, Sebastien

    2014-01-01

    This paper presents the first study that uses the GEometry ANd Tracking 4 (GEANT4) toolkit to do quantitative comparisons with other modeling results related to the production of terrestrial gamma ray flashes and high-energy particle emission from thunderstorms. We will study the relativistic runaway electron avalanche (RREA) and the relativistic feedback process, as well as the production of bremsstrahlung photons from runaway electrons. The Monte Carlo simulations take into account the effects of electron ionization, electron by electron (Møller), and electron by positron (Bhabha) scattering as well as the bremsstrahlung process and pair production, in the 250 eV to 100 GeV energy range. Our results indicate that the multiplication of electrons during the development of RREAs and under the influence of feedback are consistent with previous estimates. This is important to validate GEANT4 as a tool to model RREAs and feedback in homogeneous electric fields. We also determine the ratio of bremsstrahlung photons to energetic electrons Nγ/Ne. We then show that the ratio has a dependence on the electric field, which can be expressed by the avalanche time τ(E) and the bremsstrahlung coefficient α(ε). In addition, we present comparisons of GEANT4 simulations performed with a “standard” and a “low-energy” physics list both validated in the 1 keV to 100 GeV energy range. This comparison shows that the choice of physics list used in GEANT4 simulations has a significant effect on the results. Key Points Testing the feedback mechanism with GEANT4 Validating the GEANT4 programming toolkit Study the ratio of bremsstrahlung photons to electrons at TGF source altitude PMID:26167437

  14. Integration of Geant4 with the Gaudi Framework

    Institute of Scientific and Technical Information of China (English)

    I.Belyaev; M.Frank; 等

    2001-01-01

    The GAUDI software framework is to be used for all event-processing applications in the LHCb experiment.The GEANT4 toolkit has been integrated into GAUDI to form the basis of the LHCb simulation program GAUSS.The benefits of this approach are that it permits re-use of basic services,such as persistency,interactivity and data visualization,as well as physics algorithms that were originally developed in the context of the reconstruction and analysis programs.Following the GAUDI philosophy,the integration has been achieved by developing a number of services with abstract interfaces that can be plugged in at run-time.We describe the overall design and details of the components for interfacing the detector geometry,the primary interaction and the output from tracking particles through the detector.

  15. GEANT4 simulations of the DANCE array

    Energy Technology Data Exchange (ETDEWEB)

    Jandel, M. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States)]. E-mail: mjandel@lanl.gov; Bredeweg, T.A. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Couture, A. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Fowler, M.M. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Bond, E.M. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Chadwick, M.B. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Clement, R.R.C. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Esch, E.-I. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); O' Donnell, J.M. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Reifarth, R. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Rundberg, R.S. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Ullmann, J.L. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Vieira, D.J. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Wilhelmy, J.B. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Wouters, J.M. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Macri, R.A. [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Wu, C.Y. [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Becker, J.A. [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States)

    2007-08-15

    The detector for advanced neutron capture experiments (DANCE) at Los Alamos National Laboratory (LANL) is used for neutron capture cross sections measurements. Its high granularity of 160 BaF{sub 2} detectors in a 4{pi} geometry allows for highly efficient detection of prompt {gamma}-rays following a neutron capture. The performance of the detector was simulated using the GEANT4 Monte Carlo code. The model includes all 160 BaF{sub 2} crystals with realistic dimensions and geometry. The {sup 6}LiH shell, beam pipe, crystal wrapping material, aluminum holders, photomultiplier material and materials of the calibration sources were included in the simulation. Simulated {gamma}-ray energy and total {gamma}-ray energy spectra gated on cluster and crystal multiplicities were compared to measured data using {sup 88}Y, {sup 60}Co, {sup 22}Na calibration sources. Good agreement was achieved. A total efficiency and peak-to-total ratio as a function of {gamma}-ray energy was established for mono-energetic {gamma}-rays.

  16. GEANT4 simulations of the DANCE array

    Science.gov (United States)

    Jandel, M.; Bredeweg, T. A.; Couture, A.; Fowler, M. M.; Bond, E. M.; Chadwick, M. B.; Clement, R. R. C.; Esch, E.-I.; O'Donnell, J. M.; Reifarth, R.; Rundberg, R. S.; Ullmann, J. L.; Vieira, D. J.; Wilhelmy, J. B.; Wouters, J. M.; Macri, R. A.; Wu, C. Y.; Becker, J. A.

    2007-08-01

    The detector for advanced neutron capture experiments (DANCE) at Los Alamos National Laboratory (LANL) is used for neutron capture cross sections measurements. Its high granularity of 160 BaF2 detectors in a 4π geometry allows for highly efficient detection of prompt γ-rays following a neutron capture. The performance of the detector was simulated using the GEANT4 Monte Carlo code. The model includes all 160 BaF2 crystals with realistic dimensions and geometry. The 6LiH shell, beam pipe, crystal wrapping material, aluminum holders, photomultiplier material and materials of the calibration sources were included in the simulation. Simulated γ-ray energy and total γ-ray energy spectra gated on cluster and crystal multiplicities were compared to measured data using 88Y, 60Co, 22Na calibration sources. Good agreement was achieved. A total efficiency and peak-to-total ratio as a function of γ-ray energy was established for mono-energetic γ-rays.

  17. MCNP5 and GEANT4 comparisons for preliminary Fast Neutron Pencil Beam design at the University of Utah TRIGA system

    Science.gov (United States)

    Adjei, Christian Amevi

    The main objective of this thesis is twofold. The starting objective was to develop a model for meaningful benchmarking of different versions of GEANT4 against an experimental set-up and MCNP5 pertaining to photon transport and interactions. The following objective was to develop a preliminary design of a Fast Neutron Pencil Beam (FNPB) Facility to be applicable for the University of Utah research reactor (UUTR) using MCNP5 and GEANT4. The three various GEANT4 code versions, GEANT4.9.4, GEANT4.9.3, and GEANT4.9.2, were compared to MCNP5 and the experimental measurements of gamma attenuation in air. The average gamma dose rate was measured in the laboratory experiment at various distances from a shielded cesium source using a Ludlum model 19 portable NaI detector. As it was expected, the gamma dose rate decreased with distance. All three GEANT4 code versions agreed well with both the experimental data and the MCNP5 simulation. Additionally, a simple GEANT4 and MCNP5 model was developed to compare the code agreements for neutron interactions in various materials. Preliminary FNPB design was developed using MCNP5; a semi-accurate model was developed using GEANT4 (because GEANT4 does not support the reactor physics modeling, the reactor was represented as a surface neutron source, thus a semi-accurate model). Based on the MCNP5 model, the fast neutron flux in a sample holder of the FNPB is obtained to be 6.52×107 n/cm2s, which is one order of magnitude lower than gigantic fast neutron pencil beam facilities existing elsewhere. The MCNP5 model-based neutron spectrum indicates that the maximum expected fast neutron flux is at a neutron energy of ~1 MeV. In addition, the MCNP5 model provided information on gamma flux to be expected in this preliminary FNPB design; specifically, in the sample holder, the gamma flux is to be expected to be around 108 γ/cm 2s, delivering a gamma dose of 4.54×103 rem/hr. This value is one to two orders of magnitudes below the gamma

  18. CMS validation Experience: Test-beam 2004 data vs Geant4

    Science.gov (United States)

    Piperov, Stefan

    2007-03-01

    A comparison between the Geant4 Monte-Carlo simulation of CMS Detector's Calorimetric System and data from the 2004 Test-Beam at CERN's SPS H2 beam-line is presented. The overall simulated response agrees quite well with the measured response. Slight differences in the longitudinal shower profiles between the MC predictions made with different Physics Lists are observed.

  19. Comparison of GEANT4 very low energy cross section models with experimental data in water

    DEFF Research Database (Denmark)

    Incerti, S; Ivanchenko, A; Karamitros, M

    2010-01-01

    The GEANT4 general-purpose Monte Carlo simulation toolkit is able to simulate physical interaction processes of electrons, hydrogen and helium atoms with charge states (H0, H+) and (He0, He+, He2+), respectively, in liquid water, the main component of biological systems, down to the electron volt...

  20. SU-E-T-565: RAdiation Resistance of Cancer CElls Using GEANT4 DNA: RACE

    Energy Technology Data Exchange (ETDEWEB)

    Perrot, Y; Payno, H; Delage, E; Maigne, L [Clermont Universite, CNRS/IN2P3, Laboratoire de Physique Corpusculaire de Clermont-Ferrand, Aubiere (France); Incerti, S [Universite Bordeaux 1, CNRS/IN2P3, Centres d' Etudes Nucleaires de Bordeaux-Gradignan, Gradignan (France); Debiton, E; Peyrode, C; Chezal, J; Miot-Noirault, E; Degoul, F [Clermont Universite, Universite d' Auvergne, Imagerie Moleculaire et Therapie Vectorisee, INSERM U990, Centre Jean Perrin, Clermont-Ferrand (France)

    2014-06-01

    Purpose: The objective of the RACE project is to develop a comparison between Monte Carlo simulation using the Geant4-DNA toolkit and measurements of radiation damage on 3D melanoma and chondrosarcoma culture cells coupled with gadolinium nanoparticles. We currently expose the status of the developments regarding simulations. Methods: Monte Carlo studies are driven using the Geant4 toolkit and the Geant4-DNA extension. In order to model the geometry of a cell population, the opensource CPOP++ program is being developed for the geometrical representation of 3D cell populations including a specific cell mesh coupled with a multi-agent system. Each cell includes cytoplasm and nucleus. The correct modeling of the cell population has been validated with confocal microscopy images of spheroids. The Geant4 Livermore physics models are used to simulate the interactions of a 250 keV X-ray beam and the production of secondaries from gadolinium nanoparticles supposed to be fixed on the cell membranes. Geant4-DNA processes are used to simulate the interactions of charged particles with the cells. An atomistic description of the DNA molecule, from PDB (Protein Data Bank) files, is provided by the so-called PDB4DNA Geant4 user application we developed to score energy depositions in DNA base pairs and sugar-phosphate groups. Results: At the microscopic level, our simulations enable assessing microscopic energy distribution in each cell compartment of a realistic 3D cell population. Dose enhancement factors due to the presence of gadolinium nanoparticles can be estimated. At the nanometer scale, direct damages on nuclear DNA are also estimated. Conclusion: We successfully simulated the impact of direct radiations on a realistic 3D cell population model compatible with microdosimetry calculations using the Geant4-DNA toolkit. Upcoming validation and the future integration of the radiochemistry module of Geant4-DNA will propose to correlate clusters of ionizations with in vitro

  1. Geant4-based Monte Carlo simulations on GPU for medical applications.

    Science.gov (United States)

    Bert, Julien; Perez-Ponce, Hector; El Bitar, Ziad; Jan, Sébastien; Boursier, Yannick; Vintache, Damien; Bonissent, Alain; Morel, Christian; Brasse, David; Visvikis, Dimitris

    2013-08-21

    Monte Carlo simulation (MCS) plays a key role in medical applications, especially for emission tomography and radiotherapy. However MCS is also associated with long calculation times that prevent its use in routine clinical practice. Recently, graphics processing units (GPU) became in many domains a low cost alternative for the acquisition of high computational power. The objective of this work was to develop an efficient framework for the implementation of MCS on GPU architectures. Geant4 was chosen as the MCS engine given the large variety of physics processes available for targeting different medical imaging and radiotherapy applications. In addition, Geant4 is the MCS engine behind GATE which is actually the most popular medical applications' simulation platform. We propose the definition of a global strategy and associated structures for such a GPU based simulation implementation. Different photon and electron physics effects are resolved on the fly directly on GPU without any approximations with respect to Geant4. Validations have shown equivalence in the underlying photon and electron physics processes between the Geant4 and the GPU codes with a speedup factor of 80-90. More clinically realistic simulations in emission and transmission imaging led to acceleration factors of 400-800 respectively compared to corresponding GATE simulations.

  2. Modeling interactions of intermediate-energy neutrons in a plastic scintillator array with GEANT4

    Energy Technology Data Exchange (ETDEWEB)

    Kohley, Z., E-mail: zkohley@gmail.com [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Lunderberg, E.; DeYoung, P.A. [Department of Physics, Hope College, Holland, MI 49423 (United States); Roeder, B.T. [LPC-Caen, ENSICAEN, IN2P3/CNRS et Universite de Caen, 14050 Caen cedex (France); Baumann, T. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Christian, G.; Mosby, S.; Smith, J.K.; Snyder, J.; Spyrou, A.; Thoennessen, M. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, MI 48824 (United States); Department of Physics and Astronomy, Michigan State University, East Lansing, MI 48824 (United States)

    2012-08-01

    A Monte Carlo simulation of a large-area neutron time-of-flight detector, built on the GEANT4 framework, has been compared with an experimental measurement of the {sup 16}B{yields}{sup 15}B+n decay produced from a 55 MeV/u{sup 17}C beam. The ability of the Monte Carlo simulation to reproduce the intermediate-energy neutron interactions within the detector has been explored using both the stock GEANT4 physics processes and a custom neutron interaction model, MENATE{sub R}. The stock GEANT4 physics processes were unable to reproduce the experimental observables, while excellent agreement was obtained through the inclusion of the MENATE{sub R} model within GEANT4. The differences between the two approaches are shown to be related to the modeling of the neutron-carbon inelastic reactions. Additionally, the use of MENATE{sub R} provided accurate reproduction of experimental signals associated with neutron scattering within the detector. These results provide validation of the Monte Carlo simulation for modeling measurements of multiple neutrons where the identification and removal of false neutron signals, due to multiple neutron scattering, are required.

  3. Geant4 simulations of the lead fluoride calorimeter

    Science.gov (United States)

    Savchenko, A. A.; Tishchenko, A. A.; Dabagov, S. B.; Anastasi, A.; Venanzoni, G.; Strikhanov, M. N.; Basti, A.; Bedeschi, F.; Bartolini, M.; Cantatore, G.; Cauz, D.; Corradi, G.; Di Sciascio, G.; Di Stefano, R.; Driutti, A.; Escalante, O.; Ferrari, C.; Fioretti, A.; Gabbanini, C.; Gioiosa, A.; Hampai, D.; Iacovacci, M.; Karuza, M.; Liedl, A.; Lusiani, A.; Marignetti, F.; Mastroianni, S.; Moricciani, D.; Pauletta, G.; Piacentino, G. M.; Raha, N.; Santi, L.

    2017-07-01

    In this paper we simulate the charged particle interaction with complex structures, including the emission, with help of Geant4. We take into account Cherenkov radiation, transition radiation, bremsstrahlung, pair production and other accompanying processes. As an application we investigate the full size electromagnetic calorimeter for the muon g-2 experiment at Fermilab. A calorimeter module consists of a Delrin front panel for installation of the laser calibration system, 54 PbF2 Cherenkov crystals wrapped by black Tedlar paper, and silicon photo-multiplier sensors. We report here on results of a simulation of the radiation from positrons striking the calorimeter system. The Cherenkov radiation expansion when a positron moves down through the calorimeter at the arbitrary angle of incidence has been considered. Both spectral and angular distributions of Cherenkov optical photons in different parts of the calorimeter system was evaluated as well as the transition radiation and pre-shower distributions from both the Delrin panel and the Al vacuum chamber of the g-2 storage ring.

  4. Benchmarking Geant4 for spallation neutron source calculations

    Science.gov (United States)

    DiJulio, Douglas D.; Batkov, Konstantin; Stenander, John; Cherkashyna, Nataliia; Bentley, Phillip M.

    2016-09-01

    Geant4 is becoming increasingly used for radiation transport simulations of spallation neutron sources and related components. Historically, the code has seen little usage in this field and it is of general interest to investigate the suitability of Geant4 for such applications. For this purpose, we carried out Geant4 calculations based on simple spallation source geometries and also with the the European Spallation Source Technical Design Report target and moderator configuration. The results are compared to calculations performed with the Monte Carlo N- Particle extended code. The comparisons are carried out over the full spallation neutron source energy spectrum, from sub-eV energies up to thousands of MeV. Our preliminary results reveal that there is generally good agreement between the simulations using both codes. Additionally, we have also implemented a general weight-window generator for Geant4 based applications and present some results of the method applied to the ESS target model.

  5. An interface for GEANT4 simulation using ROOT geometry navigation

    CERN Document Server

    Gheata, A

    2008-01-01

    The ROOT geometry modeller (TGeo) offers powerful tools for detector geometry description. The package provides several functionalities like: navigation, geometry checking, enhanced visualization, geometry editing GUI and many others, using ROOT I/O. A new interface module g4root was recently developed to take advantage of ROOT geometry navigation optimizations in the context of GEANT4 simulation. The interface can be used either by native GEANT4-based simulation applications or in the more general context of the Virtual Monte Carlo (VMC) framework developed by ALICE offline and ROOT teams. The latter allows running GEANT3, GEANT4 and FLUKA simulations without changing either the geometry description or the user code. The interface was tested and stressed in the context of ALICE simulation framework. A description of the interface, its usage as well as recent results in terms of reliability and performance will be presented. Some benchmarks will be compared for ROOT-TGeo or GEANT4 based navigation.

  6. SEU rate calculation with GEANT4 (comparison with CREME 86)

    CERN Document Server

    Inguimbert, C

    2004-01-01

    This paper reports on single-event upset (SEU) rate calculations using the GEANT4 code. Single event effect rate modeling can be performed using various approaches. In this paper, we propose to compare the standard rectangular parallepiped (RPP) cosmic ray effects in microelectronic code (CREME86) model with our direct Monte Carlo simulation using the GEANT 4 (radiation transport code developed by CERN) software. The results obtained on two device types are in good agreement with CREME86. (14 refs).

  7. Consistency evaluation between EGSnrc and Geant4 charged particle transport in an equilibrium magnetic field

    Science.gov (United States)

    Yang, Y. M.; Bednarz, B.

    2013-02-01

    Following the proposal by several groups to integrate magnetic resonance imaging (MRI) with radiation therapy, much attention has been afforded to examining the impact of strong (on the order of a Tesla) transverse magnetic fields on photon dose distributions. The effect of the magnetic field on dose distributions must be considered in order to take full advantage of the benefits of real-time intra-fraction imaging. In this investigation, we compared the handling of particle transport in magnetic fields between two Monte Carlo codes, EGSnrc and Geant4, to analyze various aspects of their electromagnetic transport algorithms; both codes are well-benchmarked for medical physics applications in the absence of magnetic fields. A water-air-water slab phantom and a water-lung-water slab phantom were used to highlight dose perturbations near high- and low-density interfaces. We have implemented a method of calculating the Lorentz force in EGSnrc based on theoretical models in literature, and show very good consistency between the two Monte Carlo codes. This investigation further demonstrates the importance of accurate dosimetry for MRI-guided radiation therapy (MRIgRT), and facilitates the integration of a ViewRay MRIgRT system in the University of Wisconsin-Madison's Radiation Oncology Department.

  8. Optimization of GEANT4 settings for Proton Pencil Beam Scanning simulations using GATE

    Energy Technology Data Exchange (ETDEWEB)

    Grevillot, Loic, E-mail: loic.grevillot@gmail.co [Universite de Lyon, F-69622 Lyon (France); Creatis, CNRS UMR 5220, F-69622 Villeurbanne (France); Centre de Lutte Contre le Cancer Leon Berard, F-69373 Lyon (France); IBA, B-1348 Louvain-la-Neuve (Belgium); Frisson, Thibault [Universite de Lyon, F-69622 Lyon (France); Creatis, CNRS UMR 5220, F-69622 Villeurbanne (France); Centre de Lutte Contre le Cancer Leon Berard, F-69373 Lyon (France); Zahra, Nabil [Universite de Lyon, F-69622 Lyon (France); IPNL, CNRS UMR 5822, F-69622 Villeurbanne (France); Centre de Lutte Contre le Cancer Leon Berard, F-69373 Lyon (France); Bertrand, Damien; Stichelbaut, Frederic [IBA, B-1348 Louvain-la-Neuve (Belgium); Freud, Nicolas [Universite de Lyon, F-69622 Lyon (France); CNDRI, INSA-Lyon, F-69621 Villeurbanne Cedex (France); Sarrut, David [Universite de Lyon, F-69622 Lyon (France); Creatis, CNRS UMR 5220, F-69622 Villeurbanne (France); Centre de Lutte Contre le Cancer Leon Berard, F-69373 Lyon (France)

    2010-10-15

    This study reports the investigation of different GEANT4 settings for proton therapy applications in the context of Treatment Planning System comparisons. The GEANT4.9.2 release was used through the GATE platform. We focused on the Pencil Beam Scanning delivery technique, which allows for intensity modulated proton therapy applications. The most relevant options and parameters (range cut, step size, database binning) for the simulation that influence the dose deposition were investigated, in order to determine a robust, accurate and efficient simulation environment. In this perspective, simulations of depth-dose profiles and transverse profiles at different depths and energies between 100 and 230 MeV have been assessed against reference measurements in water and PMMA. These measurements were performed in Essen, Germany, with the IBA dedicated Pencil Beam Scanning system, using Bragg-peak chambers and radiochromic films. GEANT4 simulations were also compared to the PHITS.2.14 and MCNPX.2.5.0 Monte Carlo codes. Depth-dose simulations reached 0.3 mm range accuracy compared to NIST CSDA ranges, with a dose agreement of about 1% over a set of five different energies. The transverse profiles simulated using the different Monte Carlo codes showed discrepancies, with up to 15% difference in beam widening between GEANT4 and MCNPX in water. A 8% difference between the GEANT4 multiple scattering and single scattering algorithms was observed. The simulations showed the inability of reproducing the measured transverse dose spreading with depth in PMMA, corroborating the fact that GEANT4 underestimates the lateral dose spreading. GATE was found to be a very convenient simulation environment to perform this study. A reference physics-list and an optimized parameters-list have been proposed. Satisfactory agreement against depth-dose profiles measurements was obtained. The simulation of transverse profiles using different Monte Carlo codes showed significant deviations. This point

  9. Calculation of neutron fluence to dose equivalent conversion coefficients using GEANT4; Calculo de coeficientes de fluencia de neutrons para equivalente de dose individual utilizando o GEANT4

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, Rosane M.; Santos, Denison de S.; Queiroz Filho, Pedro P. de; Mauricio, CLaudia L.P.; Silva, Livia K. da; Pessanha, Paula R., E-mail: rosanemribeiro@oi.com.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2014-07-01

    Fluence to dose equivalent conversion coefficients provide the basis for the calculation of area and personal monitors. Recently, the ICRP has started a revision of these coefficients, including new Monte Carlo codes for benchmarking. So far, little information is available about neutron transport below 10 MeV in tissue-equivalent (TE) material performed with Monte Carlo GEANT4 code. The objective of this work is to calculate neutron fluence to personal dose equivalent conversion coefficients, H{sub p} (10)/Φ, with GEANT4 code. The incidence of monoenergetic neutrons was simulated as an expanded and aligned field, with energies ranging between thermal neutrons to 10 MeV on the ICRU slab of dimension 30 x 30 x 15 cm{sup 3}, composed of 76.2% of oxygen, 10.1% of hydrogen, 11.1% of carbon and 2.6% of nitrogen. For all incident energy, a cylindrical sensitive volume is placed at a depth of 10 mm, in the largest surface of the slab (30 x 30 cm{sup 2}). Physic process are included for neutrons, photons and charged particles, and calculations are made for neutrons and secondary particles which reach the sensitive volume. Results obtained are thus compared with values published in ICRP 74. Neutron fluence in the sensitive volume was calculated for benchmarking. The Monte Carlo GEANT4 code was found to be appropriate to calculate neutron doses at energies below 10 MeV correctly. (author)

  10. artG4: A Generic Framework for Geant4 Simulations

    Energy Technology Data Exchange (ETDEWEB)

    Arvanitis, Tasha [Harvey Mudd Coll.; Lyon, Adam [Fermilab

    2014-01-01

    A small experiment must devote its limited computing expertise to writing physics code directly applicable to the experiment. A software 'framework' is essential for providing an infrastructure that makes writing the physics-relevant code easy. In this paper, we describe a highly modular and easy to use framework for writing Geant4 based simulations called 'artg4'. This framework is a layer on top of the art framework.

  11. Geant4 simulations of the neutron production and transport in the n_TOF spallation target

    Science.gov (United States)

    Lerendegui-Marco, J.; Cortés-Giraldo, M. A.; Guerrero, C.; Quesada, J. M.

    2016-11-01

    The neutron production and transport in the spallation target of the n_TOF facility at CERN has been simulated with Geant4. The results obtained with the different hadronic Physics Lists provided by Geant4 have been compared with the experimental neutron flux in n_TOF-EAR1. The best overall agreement in both the absolute value and the energy dependence of the flux from thermal to 1GeV, is obtained with the INCL++ model coupled with the Fritiof Model(FTFP). This Physics List has been thus used to simulate and study the main features of the new n_TOF-EAR2 beam line, currently in its commissioning phase.

  12. Optimization of Voxelization Parameters in Geant4 Tracking and Improvement of the Shooter Benchmarking Program

    CERN Document Server

    Siegel, Zachary

    2013-01-01

    The geometry-based tracking of the ubiquitous particle physics simulation toolkit Geant4 utilizes the idea of voxels, which effectively partition regions into multi-dimensional slices that can decrease simulation time. The extent of voxelization and the size of the voxels is determined by a set of parameters, which until now, defaulted to arbitrary numbers. In this report I document how I tested different values for these parameters and determined which values should be the default. I modified the existing G01 Geant4 example program to get an initial look at how the performance depended on the parameters. Then I modified the Shooter benchmark program, which lacks extraneous physics processes, to collect more refined data and to provide a tool for future testers to perform comprehensive benchmarks. To this end, I created a new geometry, added features to aid in testing over ranges of parameters, and setup the default tests to provide a good sampling of different simulation scenarios.

  13. A study of the runaway relativistic electron avalanche and the feedback theory using GEANT4

    Science.gov (United States)

    Broberg Skeltved, Alexander; Østgaard, Nikolai; Carlson, Brant; Gjesteland, Thomas

    2014-05-01

    This study investigate the Runaway Relativistic Electron Avalanche (RREA) and the feedback process as well as the production of Bremsstrahlung photons from Runaway Electrons (REs). These processes are important to understand the production of the intense bursts of gamma-rays known as Terrestrial Gamma-Ray Flashes (TGFs). Results are obtained from Monte Carlo (MC) simulations using the GEometry ANd Tracking 4 (GEANT4) programming toolkit. The simulations takes into account the effects of electron ionisation, electron by electron scattering (Møller scattering) as well as positron and photon interactions, in the 250 eV-100 GeV energy range. Several physics libraries or 'physics lists' are provided with GEANT4 to implement these physics processes in the simulations. We give a detailed analysis of the electron and the feedback multiplication, in particular the avalanche lengths, Λ, the energy distribution and the feedback factor, γ. We also find that our results vary significantly depending on which physics list we implement. In order to verify our results and the GEANT4 programming toolkit, we compare them to previous results from existing models. In addition we present the ratio of the production of bremsstrahlung photons to runaway electrons. From this ratio we obtain the parameter, α, which describe the electron to photon relation.

  14. Comparison of Geant4 hadron generators with data: a critical appraisal

    CERN Document Server

    Boyko, I

    2008-01-01

    Hadron generation models are indispensable for the simulation and calibration of particle physics detectors. The models used by the Geant4 simulation tool kit are compared with inclusive spectra of secondary protons and pions from the interactions with beryllium nuclei of +8.9 GeV/c protons and pions, and of -8.0 GeV/c pions. We report on significant disagreements between data and model predictions especially in the polar-angle distributions of secondary protons and pions.

  15. R and D on co-working transport schemes in Geant4

    Energy Technology Data Exchange (ETDEWEB)

    Pia, M G; Saracco, P; Sudhakar, M [INFN Sezione di Genova, Via Dodecaneso 33, 16146 Genova (Italy); Zoglauer, A [University of California at Berkeley, Berkeley, CA 94720-7450 (United States); Augelli, M [CNES, 18 Av. Edouard Belin, 31401 Toulouse (France); Gargioni, E [University Medical Center Hamburg-Eppendorf, D-20246 Hamburg (Germany); Kim, C H [Hanyang University, 17 Haengdang-dong, Seongdong-gu, Seoul, 133-791 (Korea, Republic of); Quintieri, L [INFN Laboratori Nazionali di Frascati, Via Enrico Fermi 40, I-00044 Frascati (Italy); Filho, P P de Queiroz; Santos, D de Souza [IRD, Av. Salvador Allende, s/n. 22780-160, Rio de Janeiro, RJ (Brazil); Weidenspointner, G [MPI Halbleiterlabor, Otto-Hahn-Ring 6, D-81739 Muenchen (Germany); Begalli, M, E-mail: mariagrazia.pia@ge.infn.i [UERJ, R. Sao Francisco Xavier, 524. 20550-013, Rio de Janeiro, RJ (Brazil)

    2010-04-01

    A research and development (R and D) project related to the extension of the Geant4 toolkit has been recently launched to address fundamental methods in radiation transport simulation. The project focuses on simulation at different scales in the same experimental environment; this problem requires new methods across the current boundaries of condensed-random-walk and discrete transport schemes. The new developments have been motivated by experimental requirements in various domains, including nanodosimetry, astronomy and detector developments for high energy physics applications.

  16. R&D on co-working transport schemes in Geant4

    CERN Document Server

    Pia, M G; Sudhakar, M; Zoglauer, A; Augelli, M; Gargioni, E; Kim, C H; Quintieri, L; Filho, P P de Queiroz; Santos, D de Souza; Weidenspointner, G; Begalli, M

    2010-01-01

    A research and development (R&D) project related to the extension of the Geant4 toolkit has been recently launched to address fundamental methods in radiation transport simulation. The project focuses on simulation at different scales in the same experimental environment; this problem requires new methods across the current boundaries of condensed-random-walk and discrete transport schemes. The new developments have been motivated by experimental requirements in various domains, including nanodosimetry, astronomy and detector developments for high energy physics applications.

  17. Simulation of Auger electron emission from nanometer-size gold targets using the Geant4 Monte Carlo simulation toolkit

    Science.gov (United States)

    Incerti, S.; Suerfu, B.; Xu, J.; Ivantchenko, V.; Mantero, A.; Brown, J. M. C.; Bernal, M. A.; Francis, Z.; Karamitros, M.; Tran, H. N.

    2016-04-01

    A revised atomic deexcitation framework for the Geant4 general purpose Monte Carlo toolkit capable of simulating full Auger deexcitation cascades was implemented in June 2015 release (version 10.2 Beta). An overview of this refined framework and testing of its capabilities is presented for the irradiation of gold nanoparticles (NP) with keV photon and MeV proton beams. The resultant energy spectra of secondary particles created within and that escape the NP are analyzed and discussed. It is anticipated that this new functionality will improve and increase the use of Geant4 in the medical physics, radiobiology, nanomedicine research and other low energy physics fields.

  18. Simulation of Auger electron emission from nanometer-size gold targets using the Geant4 Monte Carlo simulation toolkit

    Energy Technology Data Exchange (ETDEWEB)

    Incerti, S., E-mail: sebastien.incerti@tdt.edu.vn [Division of Nuclear Physics, Ton Duc Thang University, Tan Phong Ward, District 7, Ho Chi Minh City (Viet Nam); Faculty of Applied Sciences, Ton Duc Thang University, Tan Phong Ward, District 7, Ho Chi Minh City (Viet Nam); Univ. Bordeaux, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); Suerfu, B.; Xu, J. [Department of Physics, Princeton University, Princeton, NJ (United States); Ivantchenko, V. [Ecoanalytica, Moscow (Russian Federation); Geant4 Associates International Ltd, Hebden Bridge (United Kingdom); Mantero, A. [SWHARD srl, via Greto di Cornigliano 6r, 16152 Genova (Italy); Brown, J.M.C. [School of Mathematics and Physics, Queen’s University Belfast, Belfast, Northern Ireland (United Kingdom); Bernal, M.A. [Instituto de Física Gleb Wataghin, Universidade Estadual de Campinas, SP (Brazil); Francis, Z. [Université Saint Joseph, Faculty of Sciences, Department of Physics, Beirut (Lebanon); Karamitros, M. [Notre Dame Radiation Laboratory, University of Notre Dame, Notre Dame, IN (United States); Tran, H.N. [Division of Nuclear Physics, Ton Duc Thang University, Tan Phong Ward, District 7, Ho Chi Minh City (Viet Nam); Faculty of Applied Sciences, Ton Duc Thang University, Tan Phong Ward, District 7, Ho Chi Minh City (Viet Nam)

    2016-04-01

    A revised atomic deexcitation framework for the Geant4 general purpose Monte Carlo toolkit capable of simulating full Auger deexcitation cascades was implemented in June 2015 release (version 10.2 Beta). An overview of this refined framework and testing of its capabilities is presented for the irradiation of gold nanoparticles (NP) with keV photon and MeV proton beams. The resultant energy spectra of secondary particles created within and that escape the NP are analyzed and discussed. It is anticipated that this new functionality will improve and increase the use of Geant4 in the medical physics, radiobiology, nanomedicine research and other low energy physics fields.

  19. Geant4 Applications for Modeling Molecular Transport in Complex Vacuum Geometries

    CERN Document Server

    Singal, J; Schindler, R

    2013-01-01

    This letter discusses a novel use of the Geant4 simulation toolkit to model molecular transport in a vacuum environment, in the molecular flow regime. The Geant4 toolkit was originally developed by the high energy physics community to simulate the interactions of elementary particles within complex detector systems. Here its capabilities are utilized to model molecular vacuum transport in geometries where other techniques are impractical. The techniques are verified with an application representing a simple vacuum geometry that has been studied previously both analytically and by basic Monte Carlo simulation. We discuss the use of an application with a very complicated geometry, that of the Large Synoptic Survey Telescope camera cryostat, to determine probabilities of transport of contaminant molecules to optical surfaces where control of contamination is crucial.

  20. Hadronic Shower Models in GEANT4: Validation Strategy and Results.

    Institute of Scientific and Technical Information of China (English)

    JohannesPeterWellisch

    2001-01-01

    Optimal exploitation of hadronic final states played a key role in successes of all recent hadron collider experiment in HEP,and the ability to use hadronic final states will continue to be one of the decisive issues during the analysis phase of the LHC experinents Monte Carlo implementations of hadronic shower models provided with GEANT4 facilitate the use of hadronic final states,and have been developed for many years.We will give an overview on the physics underlying hadronic shower simulation,discussing the three basic types of modelling;data driven,parametrisation driven,and theory driven modelling,and their respective implementation status in GEANT4.We will confront the different types of modelling with a validation suite for hadronic generators based on cross-sections measurements from thin target experiments,and expose the strength and weaknesses of the individual approaches.

  1. MedLinac2: a GEANT4 based software package for radiotherapy

    Directory of Open Access Journals (Sweden)

    Barbara Caccia

    2010-06-01

    Full Text Available Dose distribution evaluation in oncological radiotherapy treatments is an outstanding problem that requires sophisticated computing technologies to optimize the clinical results (i.e. increase the dose to the tumour and reduce the dose to the healthy tissues. Nowdays, dose calculation algorithms based on the Monte Carlo method are generally regarded as the most accurate tools for radiotherapy. The flexibility of the GEANT4 (GEometry ANd Tracking Monte Carlo particle transport simulation code allows a wide range of applications, from high-energy to medical physics. In order to disseminate and encourage the use of Monte Carlo method in oncological radiotherapy, a software package based on the GEANT4 Monte Carlo toolkit has been developed. The developed package (MedLinac2 allows to simulate in an adequate flexible way a linear accelerator for radiotherapy and to evaluate the dose distributions.

  2. A method for detector description exchange among ROOT GEANT4 and GEANT3

    Institute of Scientific and Technical Information of China (English)

    YOU Zheng-Yun; LIANG Yu-Tie; MAO Ya-Jun

    2008-01-01

    GEANT3 and GEANT4 are the detector simulation software programs that are widely used in most nuclear and particle physics experiments. ROOT is a program for framework, data analysis, online and offline software. Detector description is an important function in all these programs. Due to different detector construction methods and respective detector data representative, it is difficult to exchange the detector data among them. A new method based on GDML is developed to automatically convert the detector data among ROOT, GEANT4 and GEANT3. Any existing detector geometry in one program can be mapped to the geometry in the other two programs. In the software development of an experiment, different applications can share and reuse the same detector description. The application of this method in the PHENIX experiment upgrade and PHENIX Forward Vertex Silicon detector design is introduced.

  3. Low energy neutron propagation in MCNPX and GEANT4

    CERN Document Server

    Lemrani, R; Gerbier, G; Kudryavtsev, V A; Robinson, M; Spooner, N J C

    2006-01-01

    Simulations of neutron background from rock for underground experiments are presented. Neutron propagation through two types of rock, lead and hydrocarbon material is discussed. The results show a reasonably good agreement between GEANT4, MCNPX and GEANT3 in transporting low-energy neutrons.

  4. Geant4 models for simulation of multiple scattering

    CERN Document Server

    Ivanchenko, V N; Maire, M; Urban, L

    2010-01-01

    Recent progress in development of single and multiple scattering models within the Geant4 toolkit is presented. Different options available to users are discussed. The comparisons with the data are shown. The trade of precision versus CPU performance is discussed with the focus on LHC detectors simulation

  5. A model for multiple scattering in GEANT4

    CERN Document Server

    Urbán, László

    2006-01-01

    We present a model to simulate the multiple scattering of charged particles in matter. The model is based on Lewis theory; it does not use the Moliere formalism. It simulates the scattering of a charged particle after a given step, computes the path length correction and the lateral displacement as well. This model is used in GEANT4.

  6. Reanimation of the RICH Test Beam Simulation in GEANT4

    CERN Document Server

    Arzymatov, Kenenbek

    2017-01-01

    This test was originally developed by Sajan Easo (LHCb) ten years ago mostly for the purpose of testing the behavior of photomultipliers, but it wasn’t used in regression testing in Gauss/Geant4 famework. The goal of project is to revive simulation of cherenkov radiaton test by completing.

  7. Modeling proton and alpha elastic scattering in liquid water in Geant4-DNA

    Energy Technology Data Exchange (ETDEWEB)

    Tran, H.N., E-mail: tranngochoang@tdt.edu.vn [Division of Nuclear Physics, Ton Duc Thang University, Tan Phong Ward, District 7, Ho Chi Minh City (Viet Nam); Faculty of Applied Sciences, Ton Duc Thang University, Tan Phong Ward, District 7, Ho Chi Minh City (Viet Nam); El Bitar, Z. [Institut Pluridisciplinaire Hubert Curien/IN2P3/CNRS, Strasbourg (France); Champion, C. [Univ. Bordeaux, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); Karamitros, M. [Univ. Bordeaux, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, INCIA, UMR 5287, F-33400 Talence (France); Bernal, M.A. [Instituto de FísicaGleb Wataghin, Universida de Estadual de Campinas, SP (Brazil); Francis, Z. [Université Saint Joseph, Faculty of Science, Department of Physics, Beirut (Lebanon); The Open University, Faculty of Science, Department of Physical Sciences, Walton Hall, MK7 6AA Milton Keynes (United Kingdom); Ivantchenko, V. [Ecoanalytica, 119899 Moscow (Russian Federation); Lee, S.B.; Shin, J.I. [Proton Therapy Center, National Cancer Center, 323 Ilsan-ro, Ilsandong-gu, Goyang-si, Gyeonggi-do 410-769 (Korea, Republic of); Incerti, S. [Univ. Bordeaux, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France)

    2015-01-15

    Elastic scattering of protons and alpha (α) particles by water molecules cannot be neglected at low incident energies. However, this physical process is currently not available in the “Geant4-DNA” extension of the Geant4 Monte Carlo simulation toolkit. In this work, we report on theoretical differential and integral cross sections of the elastic scattering process for 100 eV–1 MeV incident protons and for 100 eV–10 MeV incident α particles in liquid water. The calculations are performed within the classical framework described by Everhart et al., Ziegler et al. and by the ICRU 49 Report. Then, we propose an implementation of the corresponding classes into the Geant4-DNA toolkit for modeling the elastic scattering of protons and α particles. Stopping powers as well as ranges are also reported. Then, it clearly appears that the account of the elastic scattering process in the slowing-down of the charged particle improves the agreement with the existing data in particular with the ICRU recommendations.

  8. Assessment of Geant4 prompt gamma emission yields in the context of proton therapy monitoring

    Directory of Open Access Journals (Sweden)

    Marco ePinto

    2016-01-01

    Full Text Available Monte Carlo tools have been long used to assist the research and development of solutions for proton therapy monitoring. The present work focuses on the prompt-gamma emission yields by comparing experimental data with the outcomes of the current version of Geant4 using all applicable proton inelastic models. For the case in study and using the binary cascade model, it was found that Geant4 overestimates the prompt-gamma emission yields by 40.2+/-0.3%, even though it predicts the prompt-gamma profile length of the experimental profile accurately. In addition, the default implementations of all proton inelastic models show an overestimation in the number of prompt gammas emitted. Finally, a set of built-in options and physically-sound Geant4 source code changes have been tested in order to try to improve the discrepancy observed. A satisfactory agreement was found when using the QMD model with a wave packet width equal to 1.3 fm2.

  9. Geant4 models for simulation of hadron/ion nuclear interactions at moderate and low energies.

    Science.gov (United States)

    Ivantchenko, Anton; Ivanchenko, Vladimir; Quesada, Jose-Manuel; Wright, Dennis

    The Geant4 toolkit is intended for Monte Carlo simulation of particle transport in media. It was initially designed for High Energy Physics purposes such as experiments at the Large Hadron Collider (LHC) at CERN. The toolkit offers a set of models allowing effective simulation of cosmic ray interactions with different materials. For moderate and low energy hadron/ion interactions with nuclei there are a number of competitive models: Binary and Bertini intra-nuclear cascade models, quantum molecular dynamic model (QMD), INCL/ABLA cascade model, and Chiral Invariant Phase Space Decay model (CHIPS). We report the status of these models for the recent version of Geant4 (release 9.3, December 2009). The Bertini cascade in-ternal cross sections were upgraded. The native Geant4 precompound and deexcitation models were used in the Binary cascade and QMD. They were significantly improved including emis-sion of light fragments, the Fermi break-up model, the General Evaporation Model (GEM), the multi-fragmentation model, and the fission model. Comparisons between model predictions and data for thin target experiments for neutron, proton, light ions, and isotope production are presented and discussed. The focus of these validations is concentrated on target materials important for space missions.

  10. Software Quality Metrics for Geant4: An Initial Assessment

    CERN Document Server

    Ronchieri, Elisabetta; Giacomini, Francesco

    2016-01-01

    In the context of critical applications, such as shielding and radiation protection, ensuring the quality of simulation software they depend on is of utmost importance. The assessment of simulation software quality is important not only to determine its adoption in experimental applications, but also to guarantee reproducibility of outcome over time. In this study, we present initial results from an ongoing analysis of Geant4 code based on established software metrics. The analysis evaluates the current status of the code to quantify its characteristics with respect to documented quality standards; further assessments concern evolutions over a series of release distributions. We describe the selected metrics that quantify software attributes ranging from code complexity to maintainability, and highlight what metrics are most effective at evaluating radiation transport software quality. The quantitative assessment of the software is initially focused on a set of Geant4 packages, which play a key role in a wide...

  11. Simulations of an X-Ray Detector Using Geant4

    Science.gov (United States)

    Ertley, Camden; McConnell, Mark; Bloser, Peter; Legere, Jason; Connor, Taylor; Ryan, James

    2009-10-01

    NASA's Black Hole Finder Probe mission has two proposed concepts. CASTER, one of the proposed concepts, is a scintillator based Coded Aperture Survey Telescope for Energetic Radiation. This paper focuses on the development of a simulation that accurately models the proposed CASTER detector. The current detector design consists of a Lanthanum Bromide (LaBr3) scintillator directly coupled to a multianode photomultiplier tube (MAPMT). This detector should be optimized to give the best energy and position resolution. The simulation is based on the Geant4 toolkit, a set of detector simulation tools developed at CERN. Geant4 was chosen because it accurately models radiation devices and detectors, while allowing the simulation of transport and boundary conditions of optical photons. The results of the simulation were compared with data taken in the lab with a ^57Co and an ^241Am source. Once validated, the simulations will be used to optimize the final detector design.

  12. GEANT4 simulation of slow positron beam implantation profiles

    Science.gov (United States)

    Dryzek, Jerzy; Horodek, Paweł

    2008-09-01

    The paper presents the positron implantation profiles, which are important for proper interpretation of data produced in slow-positron depth defect spectroscopy (VEPAS). In the paper, we compared the profiles reported in other publications and those obtained using the GEANT4 codes, which are used for the simulation of interaction of energetic particles with matter. The comparison shows that the GEANT4 codes produce profiles which match fairly well with those generated by other codes, which take into account more accurately processes at low energies when positrons interact with core electrons, valence electrons, plasmons etc. The profiles in different materials simulated for different implant energies were parameterized using two analytical formulas: the Makhovian profile and the profile proposed by Ghosh et al. [V.J. Ghosh, D.O. Welch, K.G. Lynn, in: E. Ottewite, A.H. WeissSlow (Eds.), Positron Beam Techniques for Solids and Surfaces, Jackson Hole, Wyoming, AIP Conference Proceedings, Vol. 303, New York, 1994, p. 37]. The adjustable parameters obtained are presented in Tables 1 and 2. The total backscattering probability obtained from the GEANT4 simulations is in agreement with experimental data reported.

  13. Evaluation on Geant4 Hadronic Models for Pion Minus, Pion Plus and Neutron Particles as Major Antiproton Annihilation Products.

    Science.gov (United States)

    Tavakoli, Mohammad Bagher; Mohammadi, Mohammad Mehdi; Reiazi, Reza; Jabbari, Keyvan

    2015-01-01

    Geant4 is an open source simulation toolkit based on C++, which its advantages progressively lead to applications in research domains especially modeling the biological effects of ionizing radiation at the sub-cellular scale. However, it was shown that Geant4 does not give a reasonable result in the prediction of antiproton dose especially in Bragg peak. One of the reasons could be lack of reliable physic model to predict the final states of annihilation products like pions. Considering the fact that most of the antiproton deposited dose is resulted from high-LET nuclear fragments following pion interaction in surrounding nucleons, we reproduced depth dose curves of most probable energy range of pions and neutron particle using Geant4. We consider this work one of the steps to understand the origin of the error and finally verification of Geant4 for antiproton tracking. Geant4 toolkit version 9.4.6.p01 and Fluka version 2006.3 were used to reproduce the depth dose curves of 220 MeV pions (both negative and positive) and 70 MeV neutrons. The geometry applied in the simulations consist a 20 × 20 × 20 cm(3) water tank, similar to that used in CERN for antiproton relative dose measurements. Different physic lists including Quark-Gluon String Precompound (QGSP)_Binary Cascade (BIC)_HP, the recommended setting for hadron therapy, were used. In the case of pions, Geant4 resulted in at least 5% dose discrepancy between different physic lists at depth close to the entrance point. Even up to 15% discrepancy was found in some cases like QBBC compared to QGSP_BIC_HP. A significant difference was observed in dose profiles of different Geant4 physic list at small depths for a beam of pions. In the case of neutrons, large dose discrepancy was observed when LHEP or LHEP_EMV lists were applied. The magnitude of this dose discrepancy could be even 50% greater than the dose calculated by LHEP (or LHEP_EMV) at larger depths. We found that effect different Geant4 physic list in

  14. Evaluation on Geant4 Hadronic Models for Pion Minus, Pion Plus and Neutron Particles as Major Antiproton Annihilation Products

    Science.gov (United States)

    Tavakoli, Mohammad Bagher; Mohammadi, Mohammad Mehdi; Reiazi, Reza; Jabbari, Keyvan

    2015-01-01

    Geant4 is an open source simulation toolkit based on C++, which its advantages progressively lead to applications in research domains especially modeling the biological effects of ionizing radiation at the sub-cellular scale. However, it was shown that Geant4 does not give a reasonable result in the prediction of antiproton dose especially in Bragg peak. One of the reasons could be lack of reliable physic model to predict the final states of annihilation products like pions. Considering the fact that most of the antiproton deposited dose is resulted from high-LET nuclear fragments following pion interaction in surrounding nucleons, we reproduced depth dose curves of most probable energy range of pions and neutron particle using Geant4. We consider this work one of the steps to understand the origin of the error and finally verification of Geant4 for antiproton tracking. Geant4 toolkit version 9.4.6.p01 and Fluka version 2006.3 were used to reproduce the depth dose curves of 220 MeV pions (both negative and positive) and 70 MeV neutrons. The geometry applied in the simulations consist a 20 × 20 × 20 cm3 water tank, similar to that used in CERN for antiproton relative dose measurements. Different physic lists including Quark-Gluon String Precompound (QGSP)_Binary Cascade (BIC)_HP, the recommended setting for hadron therapy, were used. In the case of pions, Geant4 resulted in at least 5% dose discrepancy between different physic lists at depth close to the entrance point. Even up to 15% discrepancy was found in some cases like QBBC compared to QGSP_BIC_HP. A significant difference was observed in dose profiles of different Geant4 physic list at small depths for a beam of pions. In the case of neutrons, large dose discrepancy was observed when LHEP or LHEP_EMV lists were applied. The magnitude of this dose discrepancy could be even 50% greater than the dose calculated by LHEP (or LHEP_EMV) at larger depths. We found that effect different Geant4 physic list in

  15. Implementation of the n-body Monte-Carlo event generator into the Geant4 toolkit for photonuclear studies

    Science.gov (United States)

    Luo, Wen; Lan, Hao-yang; Xu, Yi; Balabanski, Dimiter L.

    2017-03-01

    A data-based Monte Carlo simulation algorithm, Geant4-GENBOD, was developed by coupling the n-body Monte-Carlo event generator to the Geant4 toolkit, aiming at accurate simulations of specific photonuclear reactions for diverse photonuclear physics studies. Good comparisons of Geant4-GENBOD calculations with reported measurements of photo-neutron production cross-sections and yields, and with reported energy spectra of the 6Li(n,α)t reaction were performed. Good agreements between the calculations and experimental data were found and the validation of the developed program was verified consequently. Furthermore, simulations for the 92Mo(γ,p) reaction of astrophysics relevance and photo-neutron production of 99Mo/99mTc and 225Ra/225Ac radioisotopes were investigated, which demonstrate the applicability of this program. We conclude that the Geant4-GENBOD is a reliable tool for study of the emerging experiment programs at high-intensity γ-beam laboratories, such as the Extreme Light Infrastructure - Nuclear Physics facility and the High Intensity Gamma-Ray Source at Duke University.

  16. Extension of PENELOPE to protons: Simulation of nuclear reactions and benchmark with Geant4

    Energy Technology Data Exchange (ETDEWEB)

    Sterpin, E. [Center of Molecular Imaging, Radiotherapy and Oncology, Institut de recherche expérimentale et clinique, Université catholique de Louvain, Avenue Hippocrate 54, 1200 Brussels (Belgium); Sorriaux, J. [Center of Molecular Imaging, Radiotherapy and Oncology, Institut de recherche expérimentale et clinique, Université catholique de Louvain, Avenue Hippocrate 54, 1200 Brussels, Belgium and ICTEAM Institute, Université catholique de Louvain, Louvain-la-Neuve (Belgium); Vynckier, S. [Center of Molecular Imaging, Radiotherapy and Oncology, Institut de recherche expérimentale et clinique, Université catholique de Louvain, Avenue Hippocrate 54, 1200 Brussels, Belgium and Département de radiothérapie, Cliniques Universitaires Saint-Luc, Avenue Hippocrate 10, 1200 Brussels (Belgium)

    2013-11-15

    Purpose: Describing the implementation of nuclear reactions in the extension of the Monte Carlo code (MC) PENELOPE to protons (PENH) and benchmarking with Geant4.Methods: PENH is based on mixed-simulation mechanics for both elastic and inelastic electromagnetic collisions (EM). The adopted differential cross sections for EM elastic collisions are calculated using the eikonal approximation with the Dirac–Hartree–Fock–Slater atomic potential. Cross sections for EM inelastic collisions are computed within the relativistic Born approximation, using the Sternheimer–Liljequist model of the generalized oscillator strength. Nuclear elastic and inelastic collisions were simulated using explicitly the scattering analysis interactive dialin database for {sup 1}H and ICRU 63 data for {sup 12}C, {sup 14}N, {sup 16}O, {sup 31}P, and {sup 40}Ca. Secondary protons, alphas, and deuterons were all simulated as protons, with the energy adapted to ensure consistent range. Prompt gamma emission can also be simulated upon user request. Simulations were performed in a water phantom with nuclear interactions switched off or on and integral depth–dose distributions were compared. Binary-cascade and precompound models were used for Geant4. Initial energies of 100 and 250 MeV were considered. For cases with no nuclear interactions simulated, additional simulations in a water phantom with tight resolution (1 mm in all directions) were performed with FLUKA. Finally, integral depth–dose distributions for a 250 MeV energy were computed with Geant4 and PENH in a homogeneous phantom with, first, ICRU striated muscle and, second, ICRU compact bone.Results: For simulations with EM collisions only, integral depth–dose distributions were within 1%/1 mm for doses higher than 10% of the Bragg-peak dose. For central-axis depth–dose and lateral profiles in a phantom with tight resolution, there are significant deviations between Geant4 and PENH (up to 60%/1 cm for depth

  17. A macroscopic and microscopic study of radon exposure using Geant4 and MCNPX to estimate dose rates and DNA damage

    Science.gov (United States)

    van den Akker, Mary Evelyn

    Radon is considered the second-leading cause of lung cancer after smoking. Epidemiological studies have been conducted in miner cohorts as well as general populations to estimate the risks associated with high and low dose exposures. There are problems with extrapolating risk estimates to low dose exposures, mainly that the dose-response curve at low doses is not well understood. Calculated dosimetric quantities give average energy depositions in an organ or a whole body, but morphological features of an individual can affect these values. As opposed to human phantom models, Computed Tomography (CT) scans provide unique, patient-specific geometries that are valuable in modeling the radiological effects of the short-lived radon progeny sources. Monte Carlo particle transport code Geant4 was used with the CT scan data to model radon inhalation in the main bronchial bifurcation. The equivalent dose rates are near the lower bounds of estimates found in the literature, depending on source volume. To complement the macroscopic study, simulations were run in a small tissue volume in Geant4-DNA toolkit. As an expansion of Geant4 meant to simulate direct physical interactions at the cellular level, the particle track structure of the radon progeny alphas can be analyzed to estimate the damage that can occur in sensitive cellular structures like the DNA molecule. These estimates of DNA double strand breaks are lower than those found in Geant4-DNA studies. Further refinements of the microscopic model are at the cutting edge of nanodosimetry research.

  18. Geant4 simulations on Compton scattering of laser photons on relativistic electrons

    Energy Technology Data Exchange (ETDEWEB)

    Filipescu, D. [Extreme Light Infrastructure - Nuclear Physics, str. Atomistilor nr. 407, Bucharest-Magurele, P.O.BOX MG6, Romania and National Institute for Physics and Nuclear Engineering Horia Hulubei, str. Atomistilor nr. 407 (Romania); Utsunomiya, H. [Department of Physics, Konan University, Okamoto 8-9-1, Higashinada, Kobe 658-8501 (Japan); Gheorghe, I.; Glodariu, T. [National Institute for Physics and Nuclear Engineering Horia Hulubei, str. Atomistilor nr. 407 (Romania); Tesileanu, O. [Extreme Light Infrastructure - Nuclear Physics, str. Atomistilor nr. 407, Bucharest-Magurele, P.O.BOX MG6 (Romania); Shima, T.; Takahisa, K. [Research Center for Nuclear Physics, Osaka University, Suita, Osaka 567-0047 (Japan); Miyamoto, S. [Laboratory of Advanced Science and Technology for Industry, University of Hyogo, 3-1-2 Kouto, Kamigori, Hyogo 678-1205 (Japan)

    2015-02-24

    Using Geant4, a complex simulation code of the interaction between laser photons and relativistic electrons was developed. We implemented physically constrained electron beam emittance and spacial distribution parameters and we also considered a Gaussian laser beam. The code was tested against experimental data produced at the γ-ray beam line GACKO (Gamma Collaboration Hutch of Konan University) of the synchrotron radiation facility NewSUBARU. Here we will discuss the implications of transverse missallignments of the collimation system relative to the electron beam axis.

  19. Influence of Geant4 parameters on proton dose distribution

    Directory of Open Access Journals (Sweden)

    Asad Merouani

    2015-09-01

    Full Text Available Purpose: The proton therapy presents a great precision during the radiation dose delivery. It is useful when the tumor is located in a sensitive area like brain or eyes. The Monte Carlo (MC simulations are usually used in treatment planning system (TPS to estimate the radiation dose. In this paper we are interested in estimating the proton dose statistical uncertainty generated by the MC simulations. Methods: Geant4 was used in the simulation of the eye’s treatment room for 62 MeV protons therapy, installed in the Istituto Nazionale Fisica Nucleare Laboratori Nazionali del Sud (LNS-INFN facility in Catania. This code is a Monte Carlo based on software dedicated to simulate the passage of particles through the matter. In this work, we are interested in optimizing the Geant4 parameters on energy deposit distribution by proton to achieve the spatial resolution of dose distribution required for cancer therapy. We propose various simulations and compare the corresponding dose distribution inside water to evaluate the statistical uncertainties. Results: The simulated Bragg peak, based on facility model is in agreement with the experimental data, The calculations show that the mean statistical uncertainty is less than 1% for a simulation set with 5 × 104 events, 10-3 mm production threshold and a 10-2 mm step limit. Conclusion: The set of Geant4 cut and step limit values can be chosen in combination with the number of events to reach precision recommended from International Commission on Radiation Units and measurements (ICRU in Monte Carlo codes for proton therapy treatment.

  20. Calibration of the radiation monitor onboard Akebono using Geant4

    Science.gov (United States)

    Asai, Keiko; Takashima, Takeshi; Koi, Tatsumi; Nagai, Tsugunobu

    Natural high-energy electrons and protons (keV-MeV) in the space contaminate the data re-ciprocally. In order to calibrate the energy ranges and to remove data contamination on the radiation monitor (RDM) onboard the Japanese satellite, Akebono (EXOS-D), the detector is investigated using the Geant4 simulation toolkit of computational particle tracing. The semi-polar orbiting Akebono, launched in February 1989, is active now. This satellite has been observed the space environment at altitudes of several thousands km. The RDM instrument onboard Akebono monitors energetic particles in the Earth's radiation belt and gives important data accumulated for about two solar cycles. The data from RDM are for electrons in three energy channels of 0.3 MeV, protons in three energy channels of ¿ 30 MeV, and alpha particles in one energy channels of 15-45 MeV. The energy ranges are however based on information of about 20 years ago so that the data seem to include some errors actuary. In addition, these data include contamination of electrons and protons reciprocally. Actuary it is noticed that the electron data are contaminated by the solar protons but unknown quantitative amount of the contamination. Therefore we need data calibration in order to correct the energy ranges and to remove data contamination. The Geant4 simulation gives information of trajectories of incident and secondary particles whose are interacted with materials. We examine the RDM monitor using the Geant4 simulation. We find from the results that relativistic electrons of MeV behave quite complicatedly because of particle-material interaction in the instrument. The results indicate that efficiencies of detection and contamination are dependent on energy. This study compares the electron data from Akebono RDM with the simultaneous observation of CRRES and tries to lead the values of correction for each of the energy channels.

  1. MCNPX and GEANT4 simulation of γ -ray polymeric shields

    Indian Academy of Sciences (India)

    Tabbakh F

    2016-04-01

    In this work, the shielding ability of a polymeric compound with gadolinium for gamma radiation has been investigated. The conceptual calculation of radiation attenuation and energy absorption as a function of different Gd percentages and the calculation of total compound density are performed using MCNP and GEANT4. It is found that, 2 mm of the compound can reduce up to 5% and 50% of 1 MeV and 50 keV $\\gamma$-rays respectively. Both Monte Carlo tools are in a good agreement.

  2. GEANT4 simulation of electron energy deposition in extended media

    CERN Document Server

    Kadri, O; Gharbi, F; Trabelsi, A

    2007-01-01

    The present work demonstrates that GEANT4 yields a consistent description of electron transport processes in semi-infinite homogeneous and heterogeneous extended media. This comparison covers the e− energy deposition profiles in a range of elements from aluminum to tantalum through molybdenum at source energies from 0.3 to 1.0 MeV and at incident angles from 0° to 60°. The good agreement between simulation results and data confirms that the Monte Carlo used code is capable of accurate electron beam energy deposition calculation even under such conditions.

  3. Geant4 Simulation of Annihilation and excitation of Positronium

    CERN Document Server

    Gad, Andreas

    2016-01-01

    The purpose of this report is to document the work done during the summer of 2016 (18/6- 26/8) as a part of the CERN Summer Student Programme. The work has been done at the AEgIS (Antihydrogen Experiment: Gravity, Interferometry, Spectroscopy) collaboration under the supervision of Lillian Smestad and Michael Doser. The goal of the project was to create a Monte Carlo simulation in Geant4, of Positronium annihilation and excitation in the positron test chamber of the AEgIs experiment.

  4. Software Aspects of the Geant4 Validation Repository

    CERN Document Server

    Dotti, Andrea; Elvira, Daniel; Genser, Krzysztof; Yarba, Julia; Carminati, Federico; Folger, Gunter; Konstantinov, Dmitri; Pokorski, Witold; Ribon, Alberto

    2016-01-01

    The Geant4, GeantV and GENIE collaborations regularly perform validation and regression tests for simulation results. DoSSiER (Database of Scientic Simulation and Experimental Results) is being developed as a central repository to store the simulation results as well as the experimental data used for validation. DoSSiER is easily accessible via a web application. In addition, a web service allows for programmatic access to the repository to extract records in JSON or XML exchange formats. In this article, we describe the functionality and the current status of various components of DoSSiER as well as the technology choices we made.

  5. GEANT4 simulation of cyclotron radioisotope production in a solid target.

    Science.gov (United States)

    Poignant, F; Penfold, S; Asp, J; Takhar, P; Jackson, P

    2016-05-01

    The use of radioisotopes in nuclear medicine is essential for diagnosing and treating cancer. The optimization of their production is a key factor in maximizing the production yield and minimizing the associated costs. An efficient approach to this problem is the use of Monte Carlo simulations prior to experimentation. By predicting isotopes yields, one can study the isotope of interest expected activity for different energy ranges. One can also study the target contamination with other radioisotopes, especially undesired radioisotopes of the wanted chemical element which are difficult to separate from the irradiated target and might result in increasing the dose when delivering the radiopharmaceutical product to the patient. The aim of this work is to build and validate a Monte Carlo simulation platform using the GEANT4 toolkit to model the solid target system of the South Australian Health and Medical Research Institute (SAHMRI) GE Healthcare PETtrace cyclotron. It includes a GEANT4 Graphical User Interface (GUI) where the user can modify simulation parameters such as the energy, shape and current of the proton beam, the target geometry and material, the foil geometry and material and the time of irradiation. The paper describes the simulation and presents a comparison of simulated and experimental/theoretical yields for various nuclear reactions on an enriched nickel 64 target using the GEANT4 physics model QGSP_BIC_AllHP, a model recently developed to evaluate with high precision the interaction of protons with energies below 200MeV available in Geant4 version 10.1. The simulation yield of the (64)Ni(p,n)(64)Cu reaction was found to be 7.67±0.074 mCi·μA(-1) for a target energy range of 9-12MeV. Szelecsenyi et al. (1993) gives a theoretical yield of 6.71mCi·μA(-1) and an experimental yield of 6.38mCi·μA(-1). The (64)Ni(p,n)(64)Cu cross section obtained with the simulation was also verified against the yield predicted from the nuclear database TENDL and

  6. Geant4 supplied parameters for gamma reaction history at NIF

    Science.gov (United States)

    Rubery, Michael; Horsfield, Colin; Herrmann, Hans; Kim, Yongho; Mack, Joe; Young, Carl; Evans, Scott; Sedillo, Tom; Miller, Kirk; Stoeffl, Wolfgang; Grafil, Elliot

    2011-10-01

    The GRH diagnostics at NIF and Omega report ICF burn parameters through detection of multi-MeV γ emissions. Of particular interest is ` γ bang-time' (GBT), defined as the temporal separation between light impacting the capsule and peak in the nuclear reaction history; GBT can constrain shock and compression parameters, and indicate fuel/ablator mix. Early NIF commissioning experiments have identified contributions to GRH signals from n,n' γ reactions with remaining capsule ablator, hohlraum and thermo-mechanical package, outside the fuel hotspot region. Such contributions are mitigated by increasing the Cherenkov threshold above the energy of these emissions. The pressure adjustment modifies parameters important to GBT, such as cell time-of-flight and detector FWHM; corrections simulated using Geant4 are presented using models experimentally validated at Duke University. Beyond GBT, studies suggest GRH may be capable of recording ablator ρR, unfolding the DT γ spectrum, and inferring the DTγ /DTn branching ratio. All calculations rely on the energy-resolved intensity response as a function of gas pressure. Geant4 response simulations, together with calculations by LANL using the experimentally validated ACCEPT code, are also presented.

  7. The Inner Detector software moves to Geant4

    CERN Multimedia

    Elsing, M

    2004-01-01

    2004 is a year of change and of several major milestones for the Inner Detector software. The first of these milestones was met in March when a set of test events was successfully processed through Geant4 and afterwards through the full Inner Detector offline software chain. In the picture, a reconstructed single muon event from this test sample is displayed in different projections. Even though this looks almost trivial, it required the successful integration of several new software components besides Geant4 into the Inner Detector code. A new ATLAS wide Detector Description software package called GeoModel has been fully deployed in the Inner Detector as the single source of geometry information for both the simulation and the reconstruction. New code to emulate the digitization for all detectors and a new data model have been put in place to cope with the new simulation input. And finally the two major offline reconstruction packages, namely xKalman and iPatRec, were migrated to use the new Inner Detector ...

  8. \\textsc{MaGe} - a {\\sc Geant4}-based Monte Carlo Application Framework for Low-background Germanium Experiments

    CERN Document Server

    Boswell, Melissa; Detwiler, Jason A; Finnerty, Padraic; Henning, Reyco; Gehman, Victor M; Johnson, Rob A; Jordan, David V; Kazkaz, Kareem; Knapp, Markus; Kröninger, Kevin; Lenz, Daniel; Leviner, Lance; Liu, Jing; Liu, Xiang; MacMullin, Sean; Marino, Michael G; Mokhtarani, Akbar; Pandola, Luciano; Schubert, Alexis G; Schubert, Jens; Tomei, Claudia; Volynets, Oleksandr

    2010-01-01

    We describe a physics simulation software framework, MAGE, that is based on the GEANT4 simulation toolkit. MAGE is used to simulate the response of ultra-low radioactive background radiation detectors to ionizing radiation, specifically the MAJORANA and GERDA neutrinoless double-beta decay experiments. MAJORANA and GERDA use high-purity germanium detectors to search for the neutrinoless double-beta decay of 76Ge, and MAGE is jointly developed between these two collaborations. The MAGE framework contains the geometry models of common objects, prototypes, test stands, and the actual experiments. It also implements customized event generators, GEANT4 physics lists, and output formats. All of these features are available as class libraries that are typically compiled into a single executable. The user selects the particular experimental setup implementation at run-time via macros. The combination of all these common classes into one framework reduces duplication of efforts, eases comparison between simulated data...

  9. Performance Evaluation of Multithreaded Geant4 Simulations Using an Intel Xeon Phi Cluster

    OpenAIRE

    2015-01-01

    International audience; The objective of this study is to evaluate the performances of Intel Xeon Phi hardware accelerators for Geant4 simulations, especially for multithreaded applications. We present the complete methodology to guide users for the compilation of their Geant4 applications on Phi processors. Then, we propose series of benchmarks to compare the performance of Xeon CPUs and Phi processors for a Geant4 example dedicated to the simulation of electron dose point kernels, the TestE...

  10. Background neutron in the endcap and barrel regions of resistive plate chamber for compact muon solenoid/large hadron collider using GEANT4

    Indian Academy of Sciences (India)

    J T Rhee; M Jamil; Christopher Joen; Bingzhu Yin; Y J Jeon

    2007-09-01

    In this study the performance of double gap RPC has been tested by GEANT4 Monte Carlo simulation code. The detector response calculations taken as a function of the neutron energy in the range of 0.01 eV–1 GeV have been simulated through RPC set-up. In order to evaluate the response of detector in the LHC background environment, the neutron spectrum expected in the CMS muon endcap and barrel region were taken into account. A hit rate of about 165.5 Hz cm-2, 34 Hz cm-2, 33.6 Hz cm-2, and 27.0 Hz cm-2 due to an isotropic neutron source is calculated using GEANT4 standard electromagnetic package for a 20 × 20 cm2 RPC in the ME1, ME2, ME3 and ME4, respectively. While for the same neutron source and using GEANT4 package a hit rate of about 0.42 Hz cm-2, 0.7182 Hz cm-2 was measured for the MB1 and MB4 stations respectively. Similar characteristics of hit rates have been observed for GEANT4 low electromagnetic package.

  11. Simulation of a Helical Channel using GEANT4

    Energy Technology Data Exchange (ETDEWEB)

    Elvira, V. D. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Lebrun, P. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Spentzouris, P. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2001-02-01

    We present a simulation of a 72 m long cooling channel proposed by V. Balbekov based on the helical cooling concept developed by Ya. Derbenev. LiH wedge absorbers provide the energy loss mechanism and 201 MHz cavities are used for re-acceleration. They are placed inside a main solenoidal field to focus the beam. A helical field with an amplitude of 0.3 T and a period of 1.8 m provides momentum dispersion for emittance exchange.The simulation is performed using GEANT4. The total fractional transmission is 0.85, and the transverse, longitudinal, and 3-D cooling factors are 3.75, 2.27, and 14.61, respectively. Some version of this helical channel could eventually be used to replace the first section of the double flip channel to keep the longitudinal emittance under control and increase transmission. Although this is an interesting option, the technical challenges are still significant.

  12. Photon elastic scattering simulation: validation and improvements to Geant4

    CERN Document Server

    Batic, Matej; Pia, Maria Grazia; Saracco, Paolo

    2012-01-01

    Several models for the simulation of photon elastic scattering are quantitatively evaluated with respect to a large collection of experimental data retrieved from the literature. They include models based on the form factor approximation, on S-matrix calculations and on analytical parameterizations; they exploit publicly available data libraries and tabulations of theoretical calculations. Some of these models are currently implemented in general purpose Monte Carlo systems; some have been implemented and evaluated for the first time in this paper for possible use in Monte Carlo particle transport. The analysis mainly concerns the energy range between 5 keV and a few MeV. The validation process identifies the newly implemented model based on second order S-matrix calculations as the one best reproducing experimental measurements. The validation results show that, along with Rayleigh scattering, additional processes, not yet implemented in Geant4 nor in other major Monte Carlo systems, should be taken into acc...

  13. Low and High Energy Modeling in Geant4

    CERN Document Server

    Wright, Dennis H; Folger, Günter; Ivanchenko, Vladimir; Kossov, Mikhail; Starkov, Nikolai; Heikkinen, Aatos; Wellisch, Hans-Peter

    2007-01-01

    Four of the most-used Geant4 hadronic models, the Quark-gluon string, Bertini-style cascade, Binary cascade and Chiral Invariant Phase Space, are discussed. These models cover high, medium and low energies, respectively, and represent a more theoretical approach to simulating hadronic interactions than do the Low Energy and High Energy Parameterized models. The four models together do not yet cover all particles for all energies, so the Low Energy and High Energy Parameterized models, among others, are used to fill the gaps.The validity range in energy and particle type of each model is presented, as is a discussion of the models' distinguishing features. The main modeling stages are also described qualitatively and areas for improvement are pointed out for each model.

  14. Low And High Energy Modeling in GEANT4

    Energy Technology Data Exchange (ETDEWEB)

    Wright, Dennis H.; Koi, Tatsumi; /SLAC; Folger, Gunter; Ivanchenko, Vladimir; Kossov, Mikhail; Starkov, Nikolai; /CERN; Heikkinen, Aatos; /Helsinki Inst. of Phys.; Wellisch,

    2007-10-05

    Four of the most-used Geant4 hadronic models, the Quark-gluon string, Bertini-style cascade, Binary cascade and Chiral Invariant Phase Space, are discussed. These models cover high, medium and low energies, respectively, and represent a more theoretical approach to simulating hadronic interactions than do the Low Energy and High Energy Parameterized models. The four models together do not yet cover all particles for all energies, so the Low Energy and High Energy Parameterized models, among others, are used to fill the gaps. The validity range in energy and particle type of each model is presented, as is a discussion of the models' distinguishing features. The main modeling stages are also described qualitatively and areas for improvement are pointed out for each model.

  15. A GEANT4 simulation study of BESⅢ endcap TOF upgrade

    Institute of Scientific and Technical Information of China (English)

    ZHANG Hui; SHAO Ming; LI Cheng; CHEN Hong-Fang; HENG Yue-Kun; SUN Yong-Jie; TANG Ze-Bo

    2013-01-01

    A GEANT4-based Monte-Carlo (MC) model is developed to study the performance of endcap timeof-flight (ETOF) at BESⅢ.It's found that the multiple scattering effects,mainly from the materials at the MDC endcap,can cause multi-hit on the ETOF's readout cell and significantly influence the timing property of ETOF.A multi-gap resistive plate chamber (MRPC) with a smaller readout cell structure is more suitable for the ETOF detector due to significantly reduced multi-hit rate (per channel),from 71.5% for currently-used scintillator-based ETOF to 21.8% or 16.7% for MRPC-based ETOF,depending on the readout pad size used.The timing performance of an MRPC ETOF is also improved.These simulation results suggest and guide an ETOF upgrade effort at BESⅢ.

  16. Thermal neutron response of a boron-coated GEM detector via GEANT4 Monte Carlo code.

    Science.gov (United States)

    Jamil, M; Rhee, J T; Kim, H G; Ahmad, Farzana; Jeon, Y J

    2014-10-22

    In this work, we report the design configuration and the performance of the hybrid Gas Electron Multiplier (GEM) detector. In order to make the detector sensitive to thermal neutrons, the forward electrode of the GEM has been coated with the enriched boron-10 material, which works as a neutron converter. A total of 5×5cm(2) configuration of GEM has been used for thermal neutron studies. The response of the detector has been estimated via using GEANT4 MC code with two different physics lists. Using the QGSP_BIC_HP physics list, the neutron detection efficiency was determined to be about 3%, while with QGSP_BERT_HP physics list the efficiency was around 2.5%, at the incident thermal neutron energies of 25meV. The higher response of the detector proves that GEM-coated with boron converter improves the efficiency for thermal neutrons detection.

  17. GEANT4 simulation of photo-peak efficiency of small high purity germanium detectors for nuclear power plant applications

    Energy Technology Data Exchange (ETDEWEB)

    Rehman, Shakeel Ur; Mirza, Sikander M. [Department of Physics and Applied Mathematics, Pakistan Institute of Engineering and Applied Sciences, Nilore, Islamabad 45650 (Pakistan); Mirza, Nasir M., E-mail: nmm@pieas.edu.p [Department of Physics and Applied Mathematics, Pakistan Institute of Engineering and Applied Sciences, Nilore, Islamabad 45650 (Pakistan); Siddique, Muhammad Tariq [Department of Physics and Applied Mathematics, Pakistan Institute of Engineering and Applied Sciences, Nilore, Islamabad 45650 (Pakistan)

    2011-01-15

    GEANT4 - based Monte Carlo simulations have been carried out for the determination of photo-peak efficiency of heavily shielded small high purity germanium detector (HPGe) used for monitoring radiation levels in nuclear power plants. The GEANT4 simulated values of HPGe detector efficiency for point as well as for disk sources, for two different values of collimator diameter, have been found in good agreement with the corresponding published results obtained by using the MCNP code. The work has been extended to study the effect of radial displacement of a source relative to a detector on photo-peak efficiency for both point and disk source, and at various values of {gamma}-ray energies. Also the effect of disk source radius on photo-peak efficiency has been studied. Besides the results of different available physics models in GEANT4 have also been compared. The computed values of efficiency for point as well as for disk sources using the Penelope and Livermore physics models have been found correspondingly consistent for various values of {gamma}-ray energies while some differences (e.g., Penelope model yields 6.3% higher values of photo-peak efficiency for E{gamma} = 1.332 MeV, 10 mm collimator diameter) have been observed in the corresponding valued obtained by using the Standard physics model.

  18. Gamma-gamma density and lithology tools simulation based on GEANT4 advanced low energy Compton scattering (GALECS) package

    Energy Technology Data Exchange (ETDEWEB)

    Esmaeili-sani, Vahid, E-mail: vaheed_esmaeely80@yahoo.com [Department of Nuclear Engineering and Physics, Amirkabir University of Technology, P.O. Box 4155-4494, Tehran (Iran, Islamic Republic of); Moussavi-zarandi, Ali; Boghrati, Behzad; Afarideh, Hossein [Department of Nuclear Engineering and Physics, Amirkabir University of Technology, P.O. Box 4155-4494, Tehran (Iran, Islamic Republic of)

    2012-02-01

    Geophysical bore-hole data represent the physical properties of rocks, such as density and formation lithology, as a function of depth in a well. Properties of rocks are obtained from gamma ray transport logs. Transport of gamma rays, from a {sup 137}Cs point gamma source situated in a bore-hole tool, through rock media to detectors, has been simulated using a GEANT4 radiation transport code. The advanced Compton scattering concepts were used to gain better analyses about well formation. The simulation and understanding of advanced Compton scattering highly depends on how accurately the effects of Doppler broadening and Rayleigh scattering are taken into account. A Monte Carlo package that simulates the gamma-gamma well logging tools based on GEANT4 advanced low energy Compton scattering (GALECS).

  19. Energy Response and Longitudinal Shower Profiles Measured in CMS HCAL and Comparison With Geant4

    CERN Document Server

    Baiatian, G; Emeliantchik, Igor; Massolov, V; Shumeiko, Nikolai; Stefanovich, R; Damgov, Jordan; Dimitrov, Lubomir; Genchev, Vladimir; Piperov, Stefan; Vankov, Ivan; Litov, Leander; Bencze, Gyorgy; Laszlo, Andras; Pal, Andras; Vesztergombi, Gyorgy; Zálán, Peter; Fenyvesi, Andras; Bawa, Harinder Singh; Beri, Suman Bala; Bhatnagar, Vipin; Kaur, Manjit; Kohli, Jatinder Mohan; Kumar, Arun; Singh, Jas Bir; Acharya, Bannaje Sripathi; Banerjee, Sunanda; Banerjee, Sudeshna; Chendvankar, Sanjay; Dugad, Shashikant; Kalmani, Suresh Devendrappa; Katta, S; Mazumdar, Kajari; Mondal, Naba Kumar; Nagaraj, P; Patil, Mandakini Ravindra; Reddy, L; Satyanarayana, B; Sharma, Seema; Sudhakar, Katta; Verma, Piyush; Hashemi, Majid; Mohammadi-Najafabadi, M; Paktinat, S; Golutvin, Igor; Kalagin, Vladimir; Kosarev, Ivan; Ladygin, Vladimir; Mescheryakov, G; Moissenz, P; Petrosian, A; Sergeyev, S; Smirnov, Vitaly; Vishnevskiy, Alexander; Volodko, Anton; Zarubin, Anatoli; Gavrilov, Vladimir; Gershtein, Yuri; Ilyina, N; Kaftanov, Vitali; Kisselevich, I; Kolossov, V; Krokhotin, Andrey; Kuleshov, Sergey; Litvintsev, Dmitri; Ulyanov, A; Safronov, Grigory; Semenov, Sergey; Stolin, Viatcheslav; Demianov, A; Gribushin, Andrey; Kodolova, Olga; Petrushanko, Sergey; Sarycheva, Ludmila; Teplov, V; Vardanyan, Irina; Yershov, A; Abramov, Victor; Goncharov, Petr; Kalinin, Alexey; Khmelnikov, Alexander; Korablev, Andrey; Korneev, Yury; Krinitsyn, Alexander; Kryshkin, V; Lukanin, Vladimir; Pikalov, Vladimir; Ryazanov, Anton; Talov, Vladimir; Turchanovich, L; Volkov, Alexey; Camporesi, Tiziano; De Visser, Theo; Vlassov, E; Aydin, Sezgin; Bakirci, Mustafa Numan; Cerci, Salim; Dumanoglu, Isa; Eskut, Eda; Kayis-Topaksu, A; Koylu, S; Kurt, Pelin; Onengüt, G; Ozkurt, Halil; Polatoz, A; Sogut, Kenan; Topakli, Huseyin; Vergili, Mehmet; Yetkin, Taylan; Cankocak, Kerem; Esendemir, Akif; Gamsizkan, Halil; Güler, M; Ozkan, Cigdem; Sekmen, Sezen; Serin-Zeyrek, M; Sever, Ramazan; Yazgan, Efe; Zeyrek, Mehmet; Deliomeroglu, Mehmet; Dindar, Kamile; Gülmez, Erhan; Isiksal, Engin; Kaya, Mithat; Ozkorucuklu, Suat; Levchuk, Leonid; Sorokin, Pavel; Senchishin, V; Hauptman, John M; Abdullin, Salavat; Elias, John E; Elvira, D; Freeman, Jim; Green, Dan; Los, Serguei; O'Dell, Vivian; Ronzhin, Anatoly; Suzuki, Ichiro; Vidal, Richard; Whitmore, Juliana; Arcidy, M; Hazen, Eric; Heering, Arjan Hendrix; Lawlor, C; Lazic, Dragoslav; Machado, Emanuel; Rohlf, James; Varela, F; Wu, Shouxiang; Baden, Drew; Bard, Robert; Eno, Sarah Catherine; Grassi, Tullio; Jarvis, Chad; Kellogg, Richard G; Kunori, Shuichi; Mans, Jeremy; Skuja, Andris; Podrasky, V; Sanzeni, Christopher; Winn, Dave; Akgun, Ugur; Ayan, S; Duru, Firdevs; Merlo, Jean-Pierre; Mestvirishvili, Alexi; Miller, Michael; Norbeck, Edwin; Olson, Jonathan; Onel, Yasar; Schmidt, Ianos; Akchurin, Nural; Carrell, Kenneth Wayne; Gumus, Kazim; Kim, Heejong; Spezziga, Mario; Thomas, Ray; Baarmand, Marc M; Mermerkaya, Hamit; Ralich, Robert; Vodopiyanov, Igor; Kramer, Laird; Linn, Stephan; Markowitz, Pete; Cushman, Priscilla; Ma, Yousi; Sherwood, Brian; Cremaldi, Lucien Marcus; Reidy, Jim; Sanders, David A; Karmgard, Daniel John; Ruchti, Randy; Fisher, Wade Cameron; Tully, Christopher; Bodek, Arie; De Barbaro, Pawel; Budd, Howard; Chung, Yeon Sei; Haelen, T; Hagopian, Sharon; Hagopian, Vasken; Johnson, Kurtis F; Barnes, Virgil E; Laasanen, Alvin T

    2007-01-01

    The response of the CMS combined electromagnetic and hadron calorimeter to beams of pions with momenta in the range 5-300 GeV/c has been measured in the H2 test beam at CERN. The raw response with the electromagnetic compartment calibrated to electrons and the hadron compartment calibrated to 300 GeV pions may be represented by sigma = (1.2) sqrt{E} oplus (0.095) E. The fraction of energy visible in the calorimeter ranges from 0.72 at 5 GeV to 0.95 at 300 GeV, indicating a substantial nonlinearity. The intrinsic electron to hadron ratios are fit as a function of energy and found to be in the range 1.3-2.7 for the electromagnetic compartment and 1.4-1.8 for the hadronic compartment. The fits are used to correct the non-linearity of the e pi response to 5% over the entire measured range resulting in a substantially improved resolution at low energy. Longitudinal shower profile have been measured in detail and compared to Geant4 models, LHEP-3.7 and QGSP-2.8. At energies below 30 GeV, the data, LHEP and QGSP are...

  20. Geant4 Hadronic Cascade Models and CMS Data Analysis : Computational Challenges in the LHC era

    CERN Document Server

    Heikkinen, Aatos

    This work belongs to the field of computational high-energy physics (HEP). The key methods used in this thesis work to meet the challenges raised by the Large Hadron Collider (LHC) era experiments are object-orientation with software engineering, Monte Carlo simulation, the computer technology of clusters, and artificial neural networks. The first aspect discussed is the development of hadronic cascade models, used for the accurate simulation of medium-energy hadron-nucleus reactions, up to 10 GeV. These models are typically needed in hadronic calorimeter studies and in the estimation of radiation backgrounds. Various applications outside HEP include the medical field (such as hadron treatment simulations), space science (satellite shielding), and nuclear physics (spallation studies). Validation results are presented for several significant improvements released in Geant4 simulation tool, and the significance of the new models for computing in the Large Hadron Collider era is estimated. In particular, we es...

  1. GEANT4 simulation of the ACE beam line : Measurement of the energy distribution of degraded Antiproton beam and the ToF signal of generated pions.

    CERN Document Server

    BRAHIMI, Nihel

    2014-01-01

    The present document describes my 8 weeks work project as a summer student at the AEgIS experiment under the supervision of Michael Doser and what i have learned during this period . It can be devided into three main tasks which are: Theoretical preparations concerning low energy antiproton physics. Learning the basic principles of GEANT4 simu- lation toolkit. Using GEANT4 platform to follow up the work of two technical students (Logan and Conrad) in designing an experiment (ACE beam line ) which aims at improving the methods of detect- ing matter-antimatter annihilations vertices at low energies in terms of resolution and accuracy using hybrid detectors .

  2. Technical Note: Improvements in GEANT4 energy-loss model and the effect on low-energy electron transport in liquid water

    Energy Technology Data Exchange (ETDEWEB)

    Kyriakou, I., E-mail: ikyriak@cc.uoi.gr [Medical Physics Laboratory, University of Ioannina Medical School, Ioannina 45110 (Greece); Incerti, S. [Centre d’Etudes Nucléaires de Bordeaux-Gradignan, CENBG, Chemin du Solarium, Université de Bordeaux, Gradignan 33175, France and Centre d’Etudes Nucléaires de Bordeaux-Gradignan, CENBG, Chemin du Solarium, CNRS/IN2P3, Gradignan 33175 (France); Francis, Z. [Department of Physics, Faculty of Sciences, Saint Joseph University, Mkalles, Beirut (Lebanon)

    2015-07-15

    Purpose: The GEANT4-DNA physics models are upgraded by a more accurate set of electron cross sections for ionization and excitation in liquid water. The impact of the new developments on low-energy electron transport simulations by the GEANT4 Monte Carlo toolkit is examined for improving its performance in dosimetry applications at the subcellular and nanometer level. Methods: The authors provide an algorithm for an improved implementation of the Emfietzoglou model dielectric response function of liquid water used in the GEANT4-DNA existing model. The algorithm redistributes the imaginary part of the dielectric function to ensure a physically motivated behavior at the binding energies, while retaining all the advantages of the original formulation, e.g., the analytic properties and the fulfillment of the f-sum-rule. In addition, refinements in the exchange and perturbation corrections to the Born approximation used in the GEANT4-DNA existing model are also made. Results: The new ionization and excitation cross sections are significantly different from those of the GEANT4-DNA existing model. In particular, excitations are strongly enhanced relative to ionizations, resulting in higher W-values and less diffusive dose-point-kernels at sub-keV electron energies. Conclusions: An improved energy-loss model for the excitation and ionization of liquid water by low-energy electrons has been implemented in GEANT4-DNA. The suspiciously low W-values and the unphysical long tail in the dose-point-kernel have been corrected owing to a different partitioning of the dielectric function.

  3. Validation of Geant4 on Proton Transportation for Thick Absorbers: Study Based on Tschalär Experimental Data

    Science.gov (United States)

    Hoff, Gabriela; Denyak, Valeriy; Schelin, Hugo R.; Paschuk, Sergei

    2017-02-01

    Imaging techniques using protons as incident particles are currently being developed to substitute X-ray computer tomography and nuclear magnetic resonance methods in proton therapy. They deal with relatively thick targets, like the human head or trunk, where protons lose a significant part of their energy, however, they have enough energy to exit the target. The physical quantities important in proton imaging are kinetic energy, angle and coordinates of emerging proton from an absorber material. In recent times, many research groups use the Geant4 toolkit to simulate proton imaging devices. Most of the available publications about validation of Geant4 models are for thin or thick absorbers (Bragg Peak studies), that are not consistent with the contour conditions applied to proton imaging. The main objective of this work is to evaluate the kinetic energy spectrum for protons emerging from homogeneous absorbers slabs comparing it to the experimental results published by Tschalär and Maccabee, in 1970. Different models (standard and detailed) available on Geant4 (version 9.6.p03) are explored taking into account its accuracy and computational performance. This paper presents a validation for protons with incident kinetic energies of 19.68 MeV and 49.10 MeV. The validation results from the emerging protons kinetic energy spectra show that: (i) there are differences between the reference data and the data produced by different processes evoked for transportation and (ii) the validation energies are sensitive to sub-shell processes.

  4. Validation of GEANT4 Monte Carlo models with a highly granular scintillator-steel hadron calorimeter

    Science.gov (United States)

    Adloff, C.; Blaha, J.; Blaising, J.-J.; Drancourt, C.; Espargilière, A.; Gaglione, R.; Geffroy, N.; Karyotakis, Y.; Prast, J.; Vouters, G.; Francis, K.; Repond, J.; Schlereth, J.; Smith, J.; Xia, L.; Baldolemar, E.; Li, J.; Park, S. T.; Sosebee, M.; White, A. P.; Yu, J.; Buanes, T.; Eigen, G.; Mikami, Y.; Watson, N. K.; Mavromanolakis, G.; Thomson, M. A.; Ward, D. R.; Yan, W.; Benchekroun, D.; Hoummada, A.; Khoulaki, Y.; Apostolakis, J.; Dotti, A.; Folger, G.; Ivantchenko, V.; Uzhinskiy, V.; Benyamna, M.; Cârloganu, C.; Fehr, F.; Gay, P.; Manen, S.; Royer, L.; Blazey, G. C.; Dyshkant, A.; Lima, J. G. R.; Zutshi, V.; Hostachy, J.-Y.; Morin, L.; Cornett, U.; David, D.; Falley, G.; Gadow, K.; Göttlicher, P.; Günter, C.; Hermberg, B.; Karstensen, S.; Krivan, F.; Lucaci-Timoce, A.-I.; Lu, S.; Lutz, B.; Morozov, S.; Morgunov, V.; Reinecke, M.; Sefkow, F.; Smirnov, P.; Terwort, M.; Vargas-Trevino, A.; Feege, N.; Garutti, E.; Marchesini, I.; Ramilli, M.; Eckert, P.; Harion, T.; Kaplan, A.; Schultz-Coulon, H.-Ch; Shen, W.; Stamen, R.; Bilki, B.; Norbeck, E.; Onel, Y.; Wilson, G. W.; Kawagoe, K.; Dauncey, P. D.; Magnan, A.-M.; Bartsch, V.; Wing, M.; Salvatore, F.; Calvo Alamillo, E.; Fouz, M.-C.; Puerta-Pelayo, J.; Bobchenko, B.; Chadeeva, M.; Danilov, M.; Epifantsev, A.; Markin, O.; Mizuk, R.; Novikov, E.; Popov, V.; Rusinov, V.; Tarkovsky, E.; Kirikova, N.; Kozlov, V.; Smirnov, P.; Soloviev, Y.; Buzhan, P.; Ilyin, A.; Kantserov, V.; Kaplin, V.; Karakash, A.; Popova, E.; Tikhomirov, V.; Kiesling, C.; Seidel, K.; Simon, F.; Soldner, C.; Szalay, M.; Tesar, M.; Weuste, L.; Amjad, M. S.; Bonis, J.; Callier, S.; Conforti di Lorenzo, S.; Cornebise, P.; Doublet, Ph; Dulucq, F.; Fleury, J.; Frisson, T.; van der Kolk, N.; Li, H.; Martin-Chassard, G.; Richard, F.; de la Taille, Ch; Pöschl, R.; Raux, L.; Rouëné, J.; Seguin-Moreau, N.; Anduze, M.; Boudry, V.; Brient, J.-C.; Jeans, D.; Mora de Freitas, P.; Musat, G.; Reinhard, M.; Ruan, M.; Videau, H.; Bulanek, B.; Zacek, J.; Cvach, J.; Gallus, P.; Havranek, M.; Janata, M.; Kvasnicka, J.; Lednicky, D.; Marcisovsky, M.; Polak, I.; Popule, J.; Tomasek, L.; Tomasek, M.; Ruzicka, P.; Sicho, P.; Smolik, J.; Vrba, V.; Zalesak, J.; Belhorma, B.; Ghazlane, H.; Takeshita, T.; Uozumi, S.; Götze, M.; Hartbrich, O.; Sauer, J.; Weber, S.; Zeitnitz, C.

    2013-07-01

    Calorimeters with a high granularity are a fundamental requirement of the Particle Flow paradigm. This paper focuses on the prototype of a hadron calorimeter with analog readout, consisting of thirty-eight scintillator layers alternating with steel absorber planes. The scintillator plates are finely segmented into tiles individually read out via Silicon Photomultipliers. The presented results are based on data collected with pion beams in the energy range from 8 GeV to 100 GeV. The fine segmentation of the sensitive layers and the high sampling frequency allow for an excellent reconstruction of the spatial development of hadronic showers. A comparison between data and Monte Carlo simulations is presented, concerning both the longitudinal and lateral development of hadronic showers and the global response of the calorimeter. The performance of several GEANT4 physics lists with respect to these observables is evaluated.

  5. Validation of GEANT4 Monte Carlo Models with a Highly Granular Scintillator-Steel Hadron Calorimeter

    CERN Document Server

    Adloff, C; Blaising, J J; Drancourt, C; Espargiliere, A; Gaglione, R; Geffroy, N; Karyotakis, Y; Prast, J; Vouters, G; Francis, K; Repond, J; Schlereth, J; Smith, J; Xia, L; Baldolemar, E; Li, J; Park, S T; Sosebee, M; White, A P; Yu, J; Buanes, T; Eigen, G; Mikami, Y; Watson, N K; Mavromanolakis, G; Thomson, M A; Ward, D R; Yan, W; Benchekroun, D; Hoummada, A; Khoulaki, Y; Apostolakis, J; Dotti, A; Folger, G; Ivantchenko, V; Uzhinskiy, V; Benyamna, M; Cârloganu, C; Fehr, F; Gay, P; Manen, S; Royer, L; Blazey, G C; Dyshkant, A; Lima, J G R; Zutshi, V; Hostachy, J Y; Morin, L; Cornett, U; David, D; Falley, G; Gadow, K; Gottlicher, P; Gunter, C; Hermberg, B; Karstensen, S; Krivan, F; Lucaci-Timoce, A I; Lu, S; Lutz, B; Morozov, S; Morgunov, V; Reinecke, M; Sefkow, F; Smirnov, P; Terwort, M; Vargas-Trevino, A; Feege, N; Garutti, E; Marchesini, I; Ramilli, M; Eckert, P; Harion, T; Kaplan, A; Schultz-Coulon, H Ch; Shen, W; Stamen, R; Bilki, B; Norbeck, E; Onel, Y; Wilson, G W; Kawagoe, K; Dauncey, P D; Magnan, A M; Bartsch, V; Wing, M; Salvatore, F; Alamillo, E Calvo; Fouz, M C; Puerta-Pelayo, J; Bobchenko, B; Chadeeva, M; Danilov, M; Epifantsev, A; Markin, O; Mizuk, R; Novikov, E; Popov, V; Rusinov, V; Tarkovsky, E; Kirikova, N; Kozlov, V; Smirnov, P; Soloviev, Y; Buzhan, P; Ilyin, A; Kantserov, V; Kaplin, V; Karakash, A; Popova, E; Tikhomirov, V; Kiesling, C; Seidel, K; Simon, F; Soldner, C; Szalay, M; Tesar, M; Weuste, L; Amjad, M S; Bonis, J; Callier, S; Conforti di Lorenzo, S; Cornebise, P; Doublet, Ph; Dulucq, F; Fleury, J; Frisson, T; van der Kolk, N; Li, H; Martin-Chassard, G; Richard, F; de la Taille, Ch; Poschl, R; Raux, L; Rouene, J; Seguin-Moreau, N; Anduze, M; Boudry, V; Brient, J-C; Jeans, D; Mora de Freitas, P; Musat, G; Reinhard, M; Ruan, M; Videau, H; Bulanek, B; Zacek, J; Cvach, J; Gallus, P; Havranek, M; Janata, M; Kvasnicka, J; Lednicky, D; Marcisovsky, M; Polak, I; Popule, J; Tomasek, L; Tomasek, M; Ruzicka, P; Sicho, P; Smolik, J; Vrba, V; Zalesak, J; Belhorma, B; Ghazlane, H; Takeshita, T; Uozumi, S; Gotze, M; Hartbrich, O; Sauer, J; Weber, S; Zeitnitz, C

    2013-01-01

    Calorimeters with a high granularity are a fundamental requirement of the Particle Flow paradigm. This paper focuses on the prototype of a hadron calorimeter with analog readout, consisting of thirty-eight scintillator layers alternating with steel absorber planes. The scintillator plates are finely segmented into tiles individually read out via Silicon Photomultipliers. The presented results are based on data collected with pion beams in the energy range from 8GeV to 100GeV. The fine segmentation of the sensitive layers and the high sampling frequency allow for an excellent reconstruction of the spatial development of hadronic showers. A comparison between data and Monte Carlo simulations is presented, concerning both the longitudinal and lateral development of hadronic showers and the global response of the calorimeter. The performance of several GEANT4 physics lists with respect to these observables is evaluated.

  6. Validation of Geant4 fragmentation for Heavy Ion Therapy

    Science.gov (United States)

    Bolst, David; Cirrone, Giuseppe A. P.; Cuttone, Giacomo; Folger, Gunter; Incerti, Sebastien; Ivanchenko, Vladimir; Koi, Tatsumi; Mancusi, Davide; Pandola, Luciano; Romano, Francesco; Rosenfeld, Anatoly B.; Guatelli, Susanna

    2017-10-01

    12C ion therapy has had growing interest in recent years for its excellent dose conformity. However at therapeutic energies, which can be as high as 400 MeV/u, carbon ions produce secondary fragments. For an incident 400 MeV/u 12C ion beam, ∼ 70 % of the beam will undergo fragmentation before the Bragg Peak. The dosimetric and radiobiological impact of these fragments must be accurately characterised, as it can result in increasing the risk of secondary cancer for the patient as well as altering the relative biological effectiveness. This work investigates the accuracy of three different nuclear fragmentation models available in the Monte Carlo Toolkit Geant4, the Binary Intranuclear Cascade (BIC), the Quantum Molecular Dynamics (QMD) and the Liege Intranuclear Cascade (INCL++). The models were benchmarked against experimental data for a pristine 400 MeV/u 12C beam incident upon a water phantom, including fragment yield, angular and energy distribution. For fragment yields the three alternative models agreed between ∼ 5 and ∼ 35 % with experimental measurements, the QMD using the ;Frag; option gave the best agreement for lighter fragments but had reduced agreement for larger fragments. For angular distributions INCL++ was seen to provide the best agreement among the models for all elements with the exception of Hydrogen, while BIC and QMD was seen to produce broader distributions compared to experiment. BIC and QMD performed similar to one another for kinetic energy distributions while INCL++ suffered from producing lower energy distributions compared to the other models and experiment.

  7. Particle Physics in Intense Electromagnetic Fields

    CERN Document Server

    Kurilin, A V

    1999-01-01

    The quantum field theory in the presence of classical background electromagnetic fields is reviewed. We give a pedagogical introduction to the Feynman-Furry method of describing non-perturbative interactions with very strong electromagnetic fields. A particular emphasis is given to the case of the plane-wave electromagnetic field for which the charged particles' wave functions and propagators are presented. Some general features of quantum processes proceeding in the intense electromagnetic background are argued. We also discuss the possibilities of searching new physics through the investigations of quantum phenomena induced by the strong electromagnetic environment.

  8. SU-E-T-347: Validation of the Condensed History Algorithm of Geant4 Using the Fano Test

    Energy Technology Data Exchange (ETDEWEB)

    Lee, H; Mathis, M; Sawakuchi, G [The Univerity of Texas MD Anderson Cancer Center, Houston, TX (United States)

    2014-06-01

    Purpose: To validate the condensed history algorithm and physics of the Geant4 Monte Carlo toolkit for simulations of ionization chambers (ICs). This study is the first step to validate Geant4 for calculations of photon beam quality correction factors under the presence of a strong magnetic field for magnetic resonance guided linac system applications. Methods: The electron transport and boundary crossing algorithms of Geant4 version 9.6.p02 were tested under Fano conditions using the Geant4 example/application FanoCavity. User-defined parameters of the condensed history and multiple scattering algorithms were investigated under Fano test conditions for three scattering models (physics lists): G4UrbanMscModel95 (PhysListEmStandard-option3), G4GoudsmitSaundersonMsc (PhysListEmStandard-GS), and G4WentzelVIModel/G4CoulombScattering (PhysListEmStandard-WVI). Simulations were conducted using monoenergetic photon beams, ranging from 0.5 to 7 MeV and emphasizing energies from 0.8 to 3 MeV. Results: The GS and WVI physics lists provided consistent Fano test results (within ±0.5%) for maximum step sizes under 0.01 mm at 1.25 MeV, with improved performance at 3 MeV (within ±0.25%). The option3 physics list provided consistent Fano test results (within ±0.5%) for maximum step sizes above 1 mm. Optimal parameters for the option3 physics list were 10 km maximum step size with default values for other user-defined parameters: 0.2 dRoverRange, 0.01 mm final range, 0.04 range factor, 2.5 geometrical factor, and 1 skin. Simulations using the option3 physics list were ∼70 – 100 times faster compared to GS and WVI under optimal parameters. Conclusion: This work indicated that the option3 physics list passes the Fano test within ±0.5% when using a maximum step size of 10 km for energies suitable for IC calculations in a 6 MV spectrum without extensive computational times. Optimal user-defined parameters using the option3 physics list will be used in future IC simulations to

  9. Geant4-related R&D for new particle transport methods

    CERN Document Server

    Augelli, M; Evans, T; Gargioni, E; Hauf, S; Kim, C H; Kuster, M; Pia, M G; Filho, P Queiroz; Quintieri, L; Saracco, P; Santos, D Souza; Weidenspointner, G; Zoglauer, A

    2009-01-01

    A R&D project has been launched in 2009 to address fundamental methods in radiation transport simulation and revisit Geant4 kernel design to cope with new experimental requirements. The project focuses on simulation at different scales in the same experimental environment: this set of problems requires new methods across the current boundaries of condensed-random-walk and discrete transport schemes. An exploration is also foreseen about exploiting and extending already existing Geant4 features to apply Monte Carlo and deterministic transport methods in the same simulation environment. An overview of this new R&D associated with Geant4 is presented, together with the first developments in progress.

  10. Project Physics Tests 4, Light and Electromagnetism.

    Science.gov (United States)

    Harvard Univ., Cambridge, MA. Harvard Project Physics.

    Test items relating to Project Physics Unit 4 are presented in this booklet. Included are 70 multiple-choice and 22 problem-and-essay questions. Concepts of light and electromagnetism are examined on charges, reflection, electrostatic forces, electric potential, speed of light, electromagnetic waves and radiations, Oersted's and Faraday's work,…

  11. Behaviors of the percentage depth dose curves along the beam axis of a phantom filled with different clinical PTO objects, a Monte Carlo Geant4 study

    Science.gov (United States)

    EL Bakkali, Jaafar; EL Bardouni, Tarek; Safavi, Seyedmostafa; Mohammed, Maged; Saeed, Mroan

    2016-08-01

    The aim of this work is to assess the capabilities of Monte Carlo Geant4 code to reproduce the real percentage depth dose (PDD) curves generated in phantoms which mimic three important clinical treatment situations that include lung slab, bone slab, bone-lung slab geometries. It is hoped that this work will lead us to a better understanding of dose distributions in an inhomogeneous medium, and to identify any limitations of dose calculation algorithm implemented in the Geant4 code. For this purpose, the PDD dosimetric functions associated to the three clinical situations described above, were compared to one produced in a homogeneous water phantom. Our results show, firstly, that the Geant4 simulation shows potential mistakes on the shape of the calculated PDD curve of the first physical test object (PTO), and it is obviously not able to successfully predict dose values in regions near to the boundaries between two different materials. This is, surely due to the electron transport algorithm and it is well-known as the artifacts at interface phenomenon. To deal with this issue, we have added and optimized the StepMax parameter to the dose calculation program; consequently the artifacts due to the electron transport were quasi disappeared. However, the Geant4 simulation becomes painfully slow when we attempt to completely resolve the electron artifact problems by considering a smaller value of an electron StepMax parameter. After electron transport optimization, our results demonstrate the medium-level capabilities of the Geant4 code to modeling dose distribution in clinical PTO objects.

  12. Geant4 simulation of the response of phosphor screens for X-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Pistrui-Maximean, S.A. [Laboratory of Nondestructive Testing using Ionizing Radiation, INSA-Lyon Scientific and Technical University, Bat. Antoine de Saint Exupery, 69621 Villeurbanne Cedex (France)]. E-mail: simona.pistrui@insa-lyon.fr; Freud, N. [Laboratory of Nondestructive Testing using Ionizing Radiation, INSA-Lyon Scientific and Technical University, Bat. Antoine de Saint Exupery, 69621 Villeurbanne Cedex (France); Letang, J.M. [Laboratory of Nondestructive Testing using Ionizing Radiation, INSA-Lyon Scientific and Technical University, Bat. Antoine de Saint Exupery, 69621 Villeurbanne Cedex (France); Koch, A. [Thales Electron Devices, 38430 Moirans (France); Munier, B. [Thales Electron Devices, 38430 Moirans (France); Walenta, A.H. [Department of Detectors and Electronics, FB Physik, University of Siegen, 57068 Siegen (Germany); Montarou, G. [Corpuscular Physics Laboratory, Blaise Pascal University, 63177 Aubiere Cedex (France); Babot, D. [Laboratory of Nondestructive Testing using Ionizing Radiation, INSA-Lyon Scientific and Technical University, Bat. Antoine de Saint Exupery, 69621 Villeurbanne Cedex (France)

    2006-07-01

    In order to predict and optimize the response of phosphor screens, it is important to understand the role played by the different physical processes inside the scintillator layer. A simulation model based on the Monte Carlo code Geant4 was developed to determine the Modulation Transfer Function (MTF) of phosphor screens for energies used in X-ray medical imaging and nondestructive testing applications. The visualization of the dose distribution inside the phosphor layer gives an insight into how the MTF is progressively degraded by X-ray and electron transport. The simulation model allows to study the influence of physical and technological parameters on the detector performances, as well as to design and optimize new detector configurations. Preliminary MTF measurements have been carried out and agreement with experimental data has been found in the case of a commercial screen (Kodak Lanex Fine) at an X-ray tube potential of 100 kV. Further validation with other screens (transparent or granular) at different energies is under way.

  13. Extending Geant4 Parallelism with External Libraries (MPI, TBB) and Its Use on HPC Resources

    CERN Document Server

    Dotti, Andrea; Barrand, Guy; Hrivnacova, Ivana; Murakami, Koichi

    2016-01-01

    With Geant4 Version 10.0, released in December 2013, one of the most widely used Monte-Carlo codes has been ported to take full advantage of multi- and many-core CPUs thanks to the introduction of event-level parallelism via multithreading. In this paper we review recent developments to allow for a better integration of parallel Geant4 jobs with external libraries. We have chosen to develop examples using the popular Intel Threading Building Block (for short TBB) as an alternative parallelization approach to the native Geant4 POSIX. To simplify the scaling of a Geant4 application across nodes on a cluster we are improving the support of MPI in Geant4. In particular it is now possible to run an hybrid MPI/MT application that uses MPI to scale across nodes and MT to scale across cores. %The recent developments allow users to easily implement parallel application resources that scale on a very large number of nodes and cores typical of HPC resources.

  14. Use of GEANT4 vs. MCNPX for the characterization of a boron-lined neutron detector

    Science.gov (United States)

    van der Ende, B. M.; Atanackovic, J.; Erlandson, A.; Bentoumi, G.

    2016-06-01

    This work compares GEANT4 with MCNPX in the characterization of a boron-lined neutron detector. The neutron energy ranges simulated in this work (0.025 eV to 20 MeV) are the traditional domain of MCNP simulations. This paper addresses the question, how well can GEANT4 and MCNPX be employed for detailed thermal neutron detector characterization? To answer this, GEANT4 and MCNPX have been employed to simulate detector response to a 252Cf energy spectrum point source, as well as to simulate mono-energetic parallel beam source geometries. The 252Cf energy spectrum simulation results demonstrate agreement in detector count rate within 3% between the two packages, with the MCNPX results being generally closer to experiment than are those from GEANT4. The mono-energetic source simulations demonstrate agreement in detector response within 5% between the two packages for all neutron energies, and within 1% for neutron energies between 100 eV and 5 MeV. Cross-checks between the two types of simulations using ISO-8529 252Cf energy bins demonstrates that MCNPX results are more self-consistent than are GEANT4 results, by 3-4%.

  15. New Standard Evaluated Neutron Cross Section Libraries for the GEANT4 Code and First Verification

    CERN Document Server

    Mendoza, Emilio; Koi, Tatsumi; Guerrero, Carlos

    2014-01-01

    The Monte Carlo simulation of the interaction of neutrons with matter relies on evaluated nuclear data libraries and models. The evaluated libraries are compilations of measured physical parameters (such as cross sections) combined with predictions of nuclear model calculations which have been adjusted to reproduce the experimental data. The results obtained from the simulations depend largely on the accuracy of the underlying nuclear data used, and thus it is important to have access to the nuclear data libraries available, either of general use or compiled for specific applications, and to perform exhaustive validations which cover the wide scope of application of the simulation code. In this paper we describe the work performed in order to extend the capabilities of the GEANT4 toolkit for the simulation of the interaction of neutrons with matter at neutron energies up to 20 MeV and a first verification of the results obtained. Such a work is of relevance for applications as diverse as the simulation of a n...

  16. Modeling Monte Carlo of multileaf collimators using the code GEANT4

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Alex C.H.; Lima, Fernando R.A., E-mail: oliveira.ach@yahoo.com, E-mail: falima@cnen.gov.br [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Lima, Luciano S.; Vieira, Jose W., E-mail: lusoulima@yahoo.com.br [Instituto Federal de Educacao, Ciencia e Tecnologia de Pernambuco (IFPE), Recife, PE (Brazil)

    2014-07-01

    Radiotherapy uses various techniques and equipment for local treatment of cancer. The equipment most often used in radiotherapy to the patient irradiation is linear accelerator (Linac). Among the many algorithms developed for evaluation of dose distributions in radiotherapy planning, the algorithms based on Monte Carlo (MC) methods have proven to be very promising in terms of accuracy by providing more realistic results. The MC simulations for applications in radiotherapy are divided into two parts. In the first, the simulation of the production of the radiation beam by the Linac is performed and then the phase space is generated. The phase space contains information such as energy, position, direction, etc. of millions of particles (photons, electrons, positrons). In the second part the simulation of the transport of particles (sampled phase space) in certain configurations of irradiation field is performed to assess the dose distribution in the patient (or phantom). Accurate modeling of the Linac head is of particular interest in the calculation of dose distributions for intensity modulated radiation therapy (IMRT), where complex intensity distributions are delivered using a multileaf collimator (MLC). The objective of this work is to describe a methodology for modeling MC of MLCs using code Geant4. To exemplify this methodology, the Varian Millennium 120-leaf MLC was modeled, whose physical description is available in BEAMnrc Users Manual (20 11). The dosimetric characteristics (i.e., penumbra, leakage, and tongue-and-groove effect) of this MLC were evaluated. The results agreed with data published in the literature concerning the same MLC. (author)

  17. Geant4 simulation of the solar neutron telescope at Sierra Negra, Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, L.X., E-mail: xavier@geofisica.unam.m [Instituto de Geofisica, Universidad Nacional Autonoma de Mexico, 04510 D.F. (Mexico); Sanchez, F. [Comision Nacional de Energia Atomica, 1429 Buenos Aires (Argentina); Valdes-Galicia, J.F. [Instituto de Geofisica, Universidad Nacional Autonoma de Mexico, 04510 D.F. (Mexico)

    2010-02-01

    The solar neutron telescope (SNT) at Sierra Negra (19.0 deg. N, 97.3 deg. W and 4580 m.a.s.l) is part of a worldwide network of similar detectors (Valdes-Galicia et al., (2004)). This SNT has an area of 4 m{sup 2}; it is composed by four 1 mx1 mx30 cm plastic scintillators (Sci). The Telescope is completely surrounded by anti-coincidence proportional counters (PRCs) to separate charged particles from the neutron flux. In order to discard photon background it is shielded on its sides by 10 mm thick iron plates and on its top by 5 mm lead plates. It is capable of registering four different channels corresponding to four energy deposition thresholds: E>30, >60, >90 and >120 MeV. The arrival direction of neutrons is determined by gondolas of PRCs in electronic coincidence, four layers of these gondolas orthogonally located underneath the SNT, two in the NS direction and two in the EW direction. We present here simulations of the detector response to neutrons, protons, electrons and gammas in range of energies from 100 to 1000 MeV. We report on the detector efficiency and on its angular resolution for particles impinging the device with different zenith angles. The simulation code was written using the Geant4 package (Agostinelli et al., (2003)), taking into account all relevant physical processes.

  18. Radial dose distributions from protons of therapeutic energies calculated with Geant4-DNA

    Science.gov (United States)

    Wang, He; Vassiliev, Oleg N.

    2014-07-01

    Models based on the amorphous track structure approximation have been successful in predicting the biological effects of heavy charged particles. Development of such models remains an active area of research that includes applications to hadrontherapy. In such models, the radial distribution of the dose deposited by delta electrons and directly by the particle is the main characteristic of track structure. We calculated these distributions with Geant4-DNA Monte Carlo code for protons in the energy range from 10 to 100 MeV. These results were approximated by a simple formula that combines the well-known inverse square distance dependence with two factors that eliminate the divergence of the radial dose integral at both small and large distances. A clear physical interpretation is given to the asymptotic behaviour of the radial dose distribution resulting from these two factors. The proposed formula agrees with the Monte Carlo data within 10% for radial distances of up to 10 μm, which corresponds to a dose range covering over eight orders of magnitude. Differences between our results and those of previously published analytical models are discussed.

  19. Yields of positron and positron emitting nuclei for proton and carbon ion radiation therapy: a simulation study with GEANT4.

    Science.gov (United States)

    Lau, Andy; Chen, Yong; Ahmad, Salahuddin

    2012-01-01

    A Monte Carlo application is developed to investigate the yields of positron-emitting nuclei (PEN) used for proton and carbon ion range verification techniques using the GEANT4 Toolkit. A base physics list was constructed and used to simulate incident proton and carbon ions onto a PMMA or water phantom using pencil like beams. In each simulation the total yields of PEN are counted and both the PEN and their associated positron depth-distributions were recorded and compared to the incident radiation's Bragg Peak. Alterations to the physics lists are then performed to investigate the PEN yields dependence on the choice of physics list. In our study, we conclude that the yields of PEN can be estimated using the physics list presented here for range verification of incident proton and carbon ions.

  20. Simulation and Digitization of a Gas Electron Multiplier Detector Using Geant4 and an Object-Oriented Digitization Program

    Science.gov (United States)

    McMullen, Timothy; Liyanage, Nilanga; Xiong, Weizhi; Zhao, Zhiwen

    2017-01-01

    Our research has focused on simulating the response of a Gas Electron Multiplier (GEM) detector using computational methods. GEM detectors provide a cost effective solution for radiation detection in high rate environments. A detailed simulation of GEM detector response to radiation is essential for the successful adaption of these detectors to different applications. Using Geant4 Monte Carlo (GEMC), a wrapper around Geant4 which has been successfully used to simulate the Solenoidal Large Intensity Device (SoLID) at Jefferson Lab, we are developing a simulation of a GEM chamber similar to the detectors currently used in our lab. We are also refining an object-oriented digitization program, which translates energy deposition information from GEMC into electronic readout which resembles the readout from our physical detectors. We have run the simulation with beta particles produced by the simulated decay of a 90Sr source, as well as with a simulated bremsstrahlung spectrum. Comparing the simulation data with real GEM data taken under similar conditions is used to refine the simulation parameters. Comparisons between results from the simulations and results from detector tests will be presented.

  1. Application of GEANT4 radiation transport toolkit to dose calculations in anthropomorphic phantoms

    CERN Document Server

    Rodrigues, P; Peralta, L; Alves, C; Chaves, A; Lopes, M C

    2003-01-01

    In this paper we present the implementation of a dose calculation application, based on the GEANT4 Monte Carlo toolkit. Validation studies were performed with an homogeneous water phantom and an Alderson--Rando anthropomorphic phantom both irradiated with high--energy photon beams produced by a clinical linear accelerator. As input, this tool requires computer tomography images for automatic codification of voxel based geometries and phase space distributions to characterize the incident radiation field. Simulation results were compared with ionization chamber, thermoluminescent dosimetry data and commercial treatment planning system calculations. In homogeneous water phantom, overall agreement with measurements were within 1--2%. For anthropomorphic simulated setups (thorax and head irradiation) mean differences between GEANT4 and TLD measurements were less than 2%. Significant differences between GEANT4 and a semi--analytical algorithm implemented in the treatment planning system, were found in low density ...

  2. MeV Neutron Production from Thermal Neutron Capture in {6}^Li Simulated with Geant4

    CERN Document Server

    Santoro, Valentina; Bentley, Phillip M

    2015-01-01

    Various Li compounds are commonly used at neutron facilities as neutron absorbers. These compounds provide one of the highest ratios of neutron attenuation to $\\gamma$-ray production. Unfortunately, the usage of these compounds can also give rise to fast neutron emission with energies up to almost 16 MeV. Historically, some details in this fast neutron production mechanism can be absent from some modeling packages under some optimization scenarios. In this work, we tested Geant4 to assess the performance of this simulation toolkit for the fast neutron generation mechanism. We compare the results of simulations performed with Geant4 to available measurements. The outcome of our study shows that results of the Geant4 simulations are in good agreement with the available measurements for $^6$Li fast neutron production, and suitable for neutron instrument background evaluation at spallation neutron sources.

  3. MeV Neutron Production from Thermal Neutron Capture in 6Li Simulated With Geant4

    Science.gov (United States)

    Santoro, Valentina; DiJulio, Douglas D.; Bentley, Phillip M.

    2016-09-01

    Various Li compounds are commonly used at neutron facilities as neutron absorbers. These compounds provide one of the highest ratios of neutron attenuation to y- ray production. Unfortunately, the usage of these compounds can also give rise to fast neutron emission with energies up to almost 16 MeV. Historically, some details in this fast neutron production mechanism can be absent from some modeling packages under some optimization scenarios. In this work, we tested Geant4 to assess the performance of this simulation toolkit for the fast neutron generation mechanism. We compare the results of simulations performed with Geant4 to available measurements. The outcome of our study shows that results of the Geant4 simulations are in good agreement with the available measurements for 6 Li fast neutron production, and suitable for neutron instrument background evaluation at spallation neutron sources.

  4. Experimental spectra analysis in THM with the help of simulation based on Geant4 framework

    CERN Document Server

    Li, Chengbo; Zhou, Shuhua; Fu, Yuanyong; Zhou, Jing; Meng, Qiuying; Jiang, Zongjun; Wang, Xiaolian

    2014-01-01

    The Coulomb barrier and electron screening cause difficulties in directly measuring nuclear reaction cross sections of charged particles in astrophysical energies. The Trojan-horse method has been introduced to solve the difficulties as a powerful indirect tool. In order to understand experimental spectra better, Geant4 is employed to simulate the method for the first time. Validity and reliability of the simulation are examined by comparing the experimental data with simulated results. The Geant4 simulation can give useful information to understand the experimental spectra better in data analysis and is beneficial to the design for future related experiments.

  5. Semiconductor phonon and charge transport Monte Carlo simulation using Geant4

    CERN Document Server

    Brandt, D; Redl, P; Schneck, K; Asai, M; Kelsey, M; Faiez, D; Bagli, E; Cabrera, B; Partridge, R; Saab, T; Sadoulet, B

    2014-01-01

    A phonon and charge transport simulation based on the Geant4 Monte Carlo toolkit is presented. The transport code is capable of propagating acoustic phonons, electrons and holes in cryogenic crystals. Anisotropic phonon propagation, oblique carrier propagation and phonon emission by accelerated carriers are all taken into account. The simulation successfully reproduces theoretical predictions and experimental observations such as phonon caustics, heat pulse propagation times and mean carrier drift velocities. Implementation of the transport code using the Geant4 toolkit ensures availability to the wider scientific community.

  6. Monte Carlo simulation of the response to fast neutrons of a multi-gap RPC (MRPC) by using the GEANT4 code

    Energy Technology Data Exchange (ETDEWEB)

    Rhee, J. T.; Jo, H. Y.; Jamil, M.; Jeon, Y. J. [Konkuk University, Seoul (Korea, Republic of)

    2012-04-15

    This article reports the simulated response to fast neutrons of a multi-gap resistive plate chamber (MRPC) by using the GEANT4 MC code. In this study, a thin polyethylene layer, which acted as the converter material for the detection of fast neutrons, was coated on the surface of the MRPC, which acts as the converter material for the detection of fast neutrons. The converter based on the polyethylene material improved the chamber's ability to detect fast neutrons. By employing the GEANT4 MC code, fast neutrons were inserted into the converter-based MRPC chamber in the energy range of 1.0 - 20.0 MeV. The response of the polyethylene-coated MRPC were evaluated as a function of the neutron energy by using the QGSP{sub B}ERT{sub H}P and the QGSP{sub B}IC{sub H}P physics list with the GEANT4 code. For a 0.13-mm converter thickness, a detection efficiency of 6.4x10{sup -3} were found for fast neutrons with an energy of E{sub n} = 6.0 by the QGSP{sub B}ERT{sub H}P physics list. The simulation test further confirmed that a higher response of the fast neutrons could be achieved if the converter thickness were to be increased. A detailed outline of the simulation test and the obtained results are presented.

  7. BC404 scintillators as gamma locators studied via Geant4 simulations

    Science.gov (United States)

    Cortés, M. L.; Hoischen, R.; Eisenhauer, K.; Gerl, J.; Pietralla, N.

    2014-05-01

    In many applications in industry and academia, an accurate determination of the direction from where gamma rays are emitted is either needed or desirable. Ion-beam therapy treatments, the search for orphan sources, and homeland security applications are examples of fields that can benefit from directional sensitivity to gamma-radiation. Scintillation detectors are a good option for these types of applications as they have relatively low cost, are easy to handle and can be produced in a large range of different sizes. In this work a Geant4 simulation was developed to study the directional sensitivity of different BC404 scintillator geometries and arrangements. The simulation includes all the physical processes relevant for gamma detection in a scintillator. In particular, the creation and propagation of optical photons inside the scintillator was included. A simplified photomultiplier tube model was also simulated. The physical principle exploited is the angular dependence of the shape of the energy spectrum obtained from thin scintillator layers when irradiated from different angles. After an experimental confirmation of the working principle of the device and a check of the simulation, the possibilities and limitations of directional sensitivity to gamma radiation using scintillator layers was tested. For this purpose, point-like sources of typical energies expected in ion-beam therapy were used. Optimal scintillator thicknesses for different energies were determined and the setup efficiencies calculated. The use of arrays of scintillators to reconstruct the direction of incoming gamma rays was also studied. For this case, a spherical source emitting Bremsstrahlung radiation was used together with a setup consisting of scintillator layers. The capability of this setup to identify the center of the extended source was studied together with its angular resolution.

  8. GEANT4 and PHITS simulations of the shielding of neutrons from $^{252}$Cf source

    CERN Document Server

    Shin, Jae Won

    2014-01-01

    Neutron shielding simulations by using GEANT4 and PHITS code are performed. As a neutron source, $^{252}$Cf is considered and the energy distribution of the neutrons emitted from $^{252}$Cf is assumed the Watt fission spectrum. The neutron dose equivalent rates with and without the shield are estimated for shielding materials such as graphite, iron, polyethylene, NS-4-FR and KRAFTON-HB. For the neutron shielding simulations by using GEANT4, high precision (G4HP) model with G4NDL 4.2 based on ENDF-VII data are used. And for PHITS simulations, JENDL-4.0 library are used for the same purpose. It is found that differences between the shielding calculations by using GEANT4 with G4NDL 4.2 and PHITS with JENDL-4.0 library are not significant for all cases considered in this work. We investigate the accuracy of the neutron dose equivalent rates obtained from GEANT4 and PHITS by comparing our simulation results with experimental data and other values calculated earlier. Calculated neutron dose equivalent rates agree w...

  9. CLIC Detector Concepts as described in the CDR: Differences between the GEANT4 and Engineering Models

    CERN Document Server

    Elsener, K; Schlatter, D; Siegrist, N

    2011-01-01

    The CLIC_ILD and CLIC_SiD detector concepts as used for the CDR Vol. 2 in 2011 exist both in GEANT4 simulation models and in engineering layout drawings. At this early stage of a conceptual design, there are inevitably differences between these models, which are described in this note.

  10. Channeling efficiency dependence on bending radius and thermal vibration amplitude of the model for the channeling of high-energy particles in straight and bent crystals implemented in Geant4

    Energy Technology Data Exchange (ETDEWEB)

    Bagli, Enrico [INFN Sezione di Ferrara, Dipartimento di Fisica e Scienze della Terra, Università di Ferrara, Via Saragat 1, 44100 Ferrara (Italy); Asai, Makoto; Dotti, Andrea [SLAC National Accelerator Laboratory, 2575 Sand Hill Rd, Menlo Park, CA 94025 (United States); Guidi, Vincenzo [INFN Sezione di Ferrara, Dipartimento di Fisica e Scienze della Terra, Università di Ferrara, Via Saragat 1, 44100 Ferrara (Italy); Verderi, Marc [Laboratoire Leprince-Ringuet, Ecole Polytechnique, CNRS/IN2P3, F-91128 Palaiseau (France)

    2015-07-15

    Monte Carlo simulations of the interaction of particles with matter are usually done with downloadable toolkits such as Geant4. A model suitable for the implementation into Geant4 for the interaction of high-energy particles in straight and bent crystals was developed and implemented. The model relies on the continuum potential approximation. The variation of the Geant4 model for the description of the orientational effect as a function of the physical parameters for the calculation of the interplanar potential is presented. The simulations are capable of reproducing the variation of the efficiency of channeling as a function of the thermal vibration amplitude and the bending radius of a bent Si strip. The study can be useful for the simulation of the channeling effect in experiments at GeV/c energies.

  11. Project Physics Text 4, Light and Electromagnetism.

    Science.gov (United States)

    Harvard Univ., Cambridge, MA. Harvard Project Physics.

    Optical and electromagnetic fundamentals are presented in this fourth unit of the Project Physics text for use by senior high students. Development of the wave theory in the first half of the 19th Century is described to deal with optical problems at the early stage. Following explanations of electric charges and forces, field concepts are…

  12. SU-E-J-72: Geant4 Simulations of Spot-Scanned Proton Beam Treatment Plans

    Energy Technology Data Exchange (ETDEWEB)

    Kanehira, T; Sutherland, K; Matsuura, T; Umegaki, K; Shirato, H [Hokkaido University, Sapporo, Hokkaido (Japan)

    2014-06-01

    Purpose: To evaluate density inhomogeneities which can effect dose distributions for real-time image gated spot-scanning proton therapy (RGPT), a dose calculation system, using treatment planning system VQA (Hitachi Ltd., Tokyo) spot position data, was developed based on Geant4. Methods: A Geant4 application was developed to simulate spot-scanned proton beams at Hokkaido University Hospital. A CT scan (0.98 × 0.98 × 1.25 mm) was performed for prostate cancer treatment with three or four inserted gold markers (diameter 1.5 mm, volume 1.77 mm3) in or near the target tumor. The CT data was read into VQA. A spot scanning plan was generated and exported to text files, specifying the beam energy and position of each spot. The text files were converted and read into our Geant4-based software. The spot position was converted into steering magnet field strength (in Tesla) for our beam nozzle. Individual protons were tracked from the vacuum chamber, through the helium chamber, steering magnets, dose monitors, etc., in a straight, horizontal line. The patient CT data was converted into materials with variable density and placed in a parametrized volume at the isocenter. Gold fiducial markers were represented in the CT data by two adjacent voxels (volume 2.38 mm3). 600,000 proton histories were tracked for each target spot. As one beam contained about 1,000 spots, approximately 600 million histories were recorded for each beam on a blade server. Two plans were considered: two beam horizontal opposed (90 and 270 degree) and three beam (0, 90 and 270 degree). Results: We are able to convert spot scanning plans from VQA and simulate them with our Geant4-based code. Our system can be used to evaluate the effect of dose reduction caused by gold markers used for RGPT. Conclusion: Our Geant4 application is able to calculate dose distributions for spot scanned proton therapy.

  13. A free-parameter theoretical model for describing the electron elastic scattering in water in the Geant4 toolkit

    Energy Technology Data Exchange (ETDEWEB)

    Champion, C. [Universite Paul Verlaine-Metz, Laboratoire de Physique Moleculaire et des Collisions, 1 Boulevard Arago, Technopole 2000, 57078 Metz (France)], E-mail: champion@univ-metz.fr; Incerti, S. [CNRS/IN2P3, Centre d' Etudes Nucleaires de Bordeaux-Gradignan, UMR 5797, Gradignan F-33175 (France); Universite de Bordeaux, Centre d' Etudes Nucleaires de Bordeaux-Gradignan, UMR 5797, Gradignan F-33175 (France); Aouchiche, H.; Oubaziz, D. [Universite M. Mammeri, Laboratoire de Mecanique, Structure et Energetique, BP 17, Tizi-Ouzou 15000 (Algeria)

    2009-09-15

    The present work provides an accurate description of the elastic scattering process for low-energy electrons (10 eV-10 keV) in liquid water by means of a free-parameter quantum-mechanical treatment. The calculations are performed in the partial-wave formalism by means of a total interaction potential taking into account a static contribution as well as fine effects like exchange and polarization contributions. The obtained results in terms of singly differential and total cross sections exhibit relatively good agreement with available experimental data (in gaseous water). They have been incorporated into the Geant4 toolkit, which has been recently extended with physics processes for microdosimetry applications in liquid water down to the electronvolt scale. They offer an improved alternative to the semi-empirical and to the screened Rutherford models already available in this very low-energy extension.

  14. Detailed studies of hadronic showers and comparison to GEANT4 simulations with data from highly granular calorimeters

    CERN Document Server

    van der Kolk, Naomi

    2015-01-01

    The highly granular calorimeter prototypes of the CALICE collaboration have provided large data samples with precise three-dimensional information on hadronic showers with steel and tungsten absorbers and silicon, scintillator and gas detector readout. From these data sets, detailed measurements of the spatial structure, including longitudinal and lateral shower profiles and of the shower substructure and time structure are extracted. Recent analyses have extended these studies to different particle species in calorimeters with scintillator readout and steel and tungsten absorbers, to energies below 10 GeV in a silicon tungsten calorimeter and have provided first studies of the shower substructure with gaseous readout and unprecedented granularity of $1\\times1$~cm$^{2}$ over a full cubic meter. These results are confronted with Geant4 simulations with different hadronic physics models. They present new challenges to the simulation codes and provide the possibility to validate and improve the simulation of had...

  15. Physic basis of electromagnetic induction low

    Directory of Open Access Journals (Sweden)

    V.J. Kutkovetskyy

    2015-03-01

    Full Text Available The statement on the macro level of EMF dependence on change in magnetic flux in time wrong reflects the physical phenomenon of electromagnetic induction low by Faraday, because EMF can be inducted if the magnetic flux of the circuit does not change. Changing magnetic flux of the circuit when the electromotive force arises is only a result of crossing the magnetic field lines by conductor and is an exception, which applies only to certain classes of electric machines.

  16. Comparison of Geant4-DNA simulation of S-values with other Monte Carlo codes

    Energy Technology Data Exchange (ETDEWEB)

    André, T. [Université Bordeaux 1, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); Morini, F. [Research Group of Theoretical Chemistry and Molecular Modelling, Hasselt University, Agoralaan Gebouw D, B-3590 Diepenbeek (Belgium); Karamitros, M. [Université Bordeaux 1, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, INCIA, UMR 5287, F-33400 Talence (France); Delorme, R. [LPSC, Université Joseph Fourier Grenoble 1, CNRS/IN2P3, Grenoble INP, 38026 Grenoble (France); CEA, LIST, F-91191 Gif-sur-Yvette (France); Le Loirec, C. [CEA, LIST, F-91191 Gif-sur-Yvette (France); Campos, L. [Departamento de Física, Universidade Federal de Sergipe, São Cristóvão (Brazil); Champion, C. [Université Bordeaux 1, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); Groetz, J.-E.; Fromm, M. [Université de Franche-Comté, Laboratoire Chrono-Environnement, UMR CNRS 6249, Besançon (France); Bordage, M.-C. [Laboratoire Plasmas et Conversion d’Énergie, UMR 5213 CNRS-INPT-UPS, Université Paul Sabatier, Toulouse (France); Perrot, Y. [Laboratoire de Physique Corpusculaire, UMR 6533, Aubière (France); Barberet, Ph. [Université Bordeaux 1, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); and others

    2014-01-15

    Monte Carlo simulations of S-values have been carried out with the Geant4-DNA extension of the Geant4 toolkit. The S-values have been simulated for monoenergetic electrons with energies ranging from 0.1 keV up to 20 keV, in liquid water spheres (for four radii, chosen between 10 nm and 1 μm), and for electrons emitted by five isotopes of iodine (131, 132, 133, 134 and 135), in liquid water spheres of varying radius (from 15 μm up to 250 μm). The results have been compared to those obtained from other Monte Carlo codes and from other published data. The use of the Kolmogorov–Smirnov test has allowed confirming the statistical compatibility of all simulation results.

  17. Therapeutic dose simulation of a 6 MV Varian Linac photon beam using GEANT4

    Science.gov (United States)

    Salama, E.; Ali, A. S.; Khaled, N. E.; Radi, A.

    2015-10-01

    A developed program in C++ language using GEANT4 libraries was used to simulate the gantry of a 6 MV high energy photon linear accelerator (Linac). The head of a clinical linear accelerator based on the manufacturer's detailed information is simulated. More than 2× 109 primary electrons are used to create the phase space file. Evaluation of the percentage depth dose (PDD) and flatness symmetry (lateral dose profiles) in water phantom were performed. Comparisons between experimental and simulated data were carried out for three field sizes; 5 × 5, 10 × 10 and 15 × 15 cm2. A relatively good agreement appeared between computed and measured PDD. Electron contamination and spatial distribution for both photons and electrons in the simulated beam are evaluated. Moreover, the obtained lateral dose profiles at 15, 50, and 100 mm depth are compatible with the measured values. The obtained results concluded that, GEANT4 code is a promising applicable Monte Carlo program in radiotherapy applications.

  18. Simulation of positron backscattering and implantation profiles using Geant4 code

    Institute of Scientific and Technical Information of China (English)

    黄世娟; 潘子文; 刘建党; 韩荣典; 叶邦角

    2015-01-01

    For the proper interpretation of the experimental data produced in slow positron beam technique, the positron im-plantation properties are studied carefully using the latest Geant4 code. The simulated backscattering coefficients, the implantation profiles, and the median implantation depths for mono-energetic positrons with energy range from 1 keV to 50 keV normally incident on different crystals are reported. Compared with the previous experimental results, our simula-tion backscattering coefficients are in reasonable agreement, and we think that the accuracy may be related to the structures of the host materials in the Geant4 code. Based on the reasonable simulated backscattering coefficients, the adjustable parameters of the implantation profiles which are dependent on materials and implantation energies are obtained. The most important point is that we calculate the positron backscattering coefficients and median implantation depths in amorphous polymers for the first time and our simulations are in fairly good agreement with the previous experimental results.

  19. Shielding studies for 2.5 MeV neutrons using GEANT4

    Science.gov (United States)

    Tovar, Felipe; Castro-Colin, Miguel; Sajo-Bohus, Laszlo

    2008-10-01

    By means of the software GEANT4, a toolkit based on the Monte Carlo method, we seek to study the dispersive effects that 2.5 MeV neutrons have, as well the gamma-yield, after interacting with various attenuating materials with simple geometrical configurations. A simulated mass of Uranium-238 is considered in the study with the purpose of observing the behavior of its characteristic yield after fast neutron irradiation.

  20. Geant4 simulation of a filtered X-ray source for radiation damage studies

    Science.gov (United States)

    Guthoff, M.; Brovchenko, O.; de Boer, W.; Dierlamm, A.; Müller, T.; Ritter, A.; Schmanau, M.; Simonis, H.-J.

    2012-05-01

    Geant4 low energy extensions have been used to simulate the X-ray spectra of industrial X-ray tubes with filters for removing the uncertain low energy part of the spectrum in a controlled way. The results are compared with precisely measured X-ray spectra using a silicon drift detector. Furthermore, this paper shows how the different dose rates in silicon and silicon dioxide layers of an electronic device can be deduced from the simulations.

  1. Geant4 Simulation of a filtered X-ray Source for Radiation Damage Studies

    CERN Document Server

    Guthoff, M; de Boer, W; Dierlamm, A; Müller, T; Ritter, A; Schmanau, M; Simonis, H -J

    2012-01-01

    Geant4 low energy extensions have been used to simulate the X-ray spectra of industrial X-ray tubes with filters for removing the uncertain low energy part of the spectrum in a controlled way. The results are compared with precisely measured X-ray spectra using a silicon drift detector. Furthermore, this paper shows how the different dose rates in silicon and silicon dioxide layers of an electronic device can be deduced from the simulations.

  2. Comparisons of Electron and Muon Signals in the Atlas Liquid Argon Calorimeters with GEANT4 Simulations

    Science.gov (United States)

    Benchekroun, D.; Karpetian, G.; Mazini, R.; Kiryunin, A.; Salihagic, D.; Strizenec, P.; Kish, J.; Kordas, K.; Parrour, G.; Leltchouk, M.; Negroni, S.; Seligman, W.; Loch, P.; Soukharev, A.

    2002-01-01

    Signals from electrons and muons taken at testbeams with different modules of the ATLAS Liquid Argon Calorimeter have been compared to corresponding simulations using the GEANT4 toolkit. These simulations have also been compared in some detail with GEANT3 based predictions. Results for signal linearity, energy resolution, and shower shapes all generally indicate a good agreement between experiment and the two simulation packages, typically at the level of a few percent.

  3. Use of GEANT4 programme package for radiation technological modeling problems

    CERN Document Server

    Bratchenko, M I

    2001-01-01

    The results of pilot computer experiments directed toward the application of Geant4 package for modeling of gamma radiation dose distributions in homogeneous phantoms are presented. we demonstrate the potential of the package it self and of the developed add-on software modules for the calculations of three-dimensional absorbed dose distributions taking into account the design and geometry of model irradiators and phantoms.

  4. GEANT4 simulations of the n{sub T}OF spallation source and their benchmarking

    Energy Technology Data Exchange (ETDEWEB)

    Lo Meo, S. [Research Centre ' ' Ezio Clementel' ' , ENEA, Bologna (Italy); Section of Bologna, INFN, Bologna (Italy); Cortes-Giraldo, M.A.; Lerendegui-Marco, J.; Guerrero, C.; Quesada, J.M. [Universidad de Sevilla, Facultad de Fisica, Sevilla (Spain); Massimi, C.; Vannini, G. [Section of Bologna, INFN, Bologna (Italy); University of Bologna, Physics and Astronomy Dept. ' ' Alma Mater Studiorum' ' , Bologna (Italy); Barbagallo, M.; Colonna, N. [INFN, Section of Bari, Bari (Italy); Mancusi, D. [CEA-Saclay, DEN, DM2S, SERMA, LTSD, Gif-sur-Yvette CEDEX (France); Mingrone, F. [Section of Bologna, INFN, Bologna (Italy); Sabate-Gilarte, M. [Universidad de Sevilla, Facultad de Fisica, Sevilla (Spain); European Organization for Nuclear Research (CERN), Geneva (Switzerland); Vlachoudis, V. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Collaboration: The n_TOF Collaboration

    2015-12-15

    Neutron production and transport in the spallation target of the n{sub T}OF facility at CERN has been simulated with GEANT4. The results obtained with different models of high-energy nucleon-nucleus interaction have been compared with the measured characteristics of the neutron beam, in particular the flux and its dependence on neutron energy, measured in the first experimental area. The best agreement at present, within 20% for the absolute value of the flux, and within few percent for the energy dependence in the whole energy range from thermal to 1 GeV, is obtained with the INCL++ model coupled with the GEANT4 native de-excitation model. All other available models overestimate by a larger factor, of up to 70%, the n{sub T}OF neutron flux. The simulations are also able to accurately reproduce the neutron beam energy resolution function, which is essentially determined by the moderation time inside the target/moderator assembly. The results here reported provide confidence on the use of GEANT4 for simulations of spallation neutron sources. (orig.)

  5. The Geant4 Visualisation System - a multi-driver graphics system

    CERN Document Server

    Allison, John; Kimura, Akinori; Perl, Joseph

    2013-01-01

    From the beginning the Geant4 Visualisation System was designed to support several simultaneous graphics systems written to common abstract interfaces. Today it has matured into a powerful diagnostic and presentational tool. It comes with a library of models that may be added to the current scene and which include the representation of the Geant4 geometry hierarchy, simulated trajectories and user-written hits and digitisations. The workhorse is the OpenGL suite of drivers for X, Xm, Qt and Win32. There is an Open Inventor driver. Scenes can be exported in special graphics formats for offline viewing in the DAWN, VRML, HepRApp and gMocren browsers. PostScript can be generated through OpenGL, Open Inventor, DAWN and HepRApp. Geant4's own tracking algorithms are used by the Ray Tracer. Not all drivers support all features but all drivers bring added functionality of some sort. This paper describes the interfaces and details the individual drivers.

  6. Geant4 Model Validation of Compton Suppressed System for Process monitoring of Spent Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Bender, Sarah; Unlu, Kenan; Orton, Christopher R.; Schwantes, Jon M.

    2013-05-01

    Nuclear material accountancy is of continuous concern for the regulatory, safeguards, and verification communities. In particular, spent nuclear fuel reprocessing facilities pose one of the most difficult accountancy challenges: monitoring highly radioactive, fluid sample streams in near real-time. The Multi-Isotope Process monitor will allow for near-real-time indication of process alterations using passive gamma-ray detection coupled with multivariate analysis techniques to guard against potential material diversion or to enhance domestic process monitoring. The Compton continuum from the dominant 661.7 keV 137Cs fission product peak obscures lower energy lines which could be used for spectral and multivariate analysis. Compton suppression may be able to mitigate the challenges posed by the high continuum caused by scattering. A Monte Carlo simulation using the Geant4 toolkit is being developed to predict the expected suppressed spectrum from spent fuel samples to estimate the reduction in the Compton continuum. Despite the lack of timing information between decay events in the particle management of Geant4, encouraging results were recorded utilizing only the information within individual decays without accounting for accidental coincidences. The model has been validated with single and cascade decay emitters in two steps: as an unsuppressed system and with suppression activated. Results of the Geant4 model validation will be presented.

  7. Response of a proportional counter to $^{37}$Ar and $^{71}$Ge: real spectra versus GEANT4 simulation

    CERN Document Server

    Abdurashitov, D; Matushko, V; Suerfu, B

    2015-01-01

    The energy deposition spectra of $^{37}$Ar and $^{71}$Ge in a miniature proportional counter are measured and compared in detail to the model response simulated with Geant4. The spectrum of $^{71}$Ge is measured with total statistics of 1.7$\\cdot$10$^8$ events and is presented for the first time. A certain modification of the Geant4 code, making it possible to trace the deexcitation of atomic shells properly, is suggested. After the modification Geant4 is able to reproduce a response of particle detectors in detail in a keV energy range. This feature is very important in the laboratory experiments that search for massive sterile neutrinos as well as for dark matter directly by detection of recoil nuclei. We expect this work to convince physicists to trust Geant4 simulations at low energies.

  8. DEF: The Physical Basis of Electromagnetic Propulsion

    CERN Document Server

    Pinheiro, Mario J

    2015-01-01

    The very existence of the physical vacuum provides a framework to propose a general mechanism for propelling bodies through an agency of electromagnetic fields, that seat in that medium. When two sub-systems of a general closed device interact via nonlocal and retarded electromagnetic pulses, it is easily shown that they give a nonzero force, and that only tend to comply with the action-to-reaction force in the limit of instantaneous interactions. The arrangement of sub-systems provide a handy way to optimize the unbalanced EM force with the concept of impedance matching. The general properties of the differential electromagnetic force (DEF) are the following: i) it is proportional to the square of the intensity and to the angular wave frequency $\\omega$; ii) to the space between the sub-systems (although in a non-linear manner); iii) it is inversely proportional to the speed of interaction; iv) when the two sub-systems are out-of-phase, DEF is null. The approach is of interest to practical engineering princi...

  9. Comparison of GEANT4 Simulations with Testbeam Data and GEANT3 for the ATLAS Liquid Argon Calorimeter

    Institute of Scientific and Technical Information of China (English)

    D.Benchekroun; G.Karapetian; 等

    2001-01-01

    We present several comparisons of GEANT4 simulations with test beam data and GEANT3 simulations for different liquid argon(LAr) calorimeters of the ATLAS detector,All relevant parts of the test beam setup(scintilators,multi wire proportional chambers,cryostat etc.)are described in GEANT4 as well as in GEANT3.Muon and electron data at different energies have been compared with Monte Carlo prediction.

  10. Electromagnetic Physics Models for Parallel Computing Architectures

    Science.gov (United States)

    Amadio, G.; Ananya, A.; Apostolakis, J.; Aurora, A.; Bandieramonte, M.; Bhattacharyya, A.; Bianchini, C.; Brun, R.; Canal, P.; Carminati, F.; Duhem, L.; Elvira, D.; Gheata, A.; Gheata, M.; Goulas, I.; Iope, R.; Jun, S. Y.; Lima, G.; Mohanty, A.; Nikitina, T.; Novak, M.; Pokorski, W.; Ribon, A.; Seghal, R.; Shadura, O.; Vallecorsa, S.; Wenzel, S.; Zhang, Y.

    2016-10-01

    The recent emergence of hardware architectures characterized by many-core or accelerated processors has opened new opportunities for concurrent programming models taking advantage of both SIMD and SIMT architectures. GeantV, a next generation detector simulation, has been designed to exploit both the vector capability of mainstream CPUs and multi-threading capabilities of coprocessors including NVidia GPUs and Intel Xeon Phi. The characteristics of these architectures are very different in terms of the vectorization depth and type of parallelization needed to achieve optimal performance. In this paper we describe implementation of electromagnetic physics models developed for parallel computing architectures as a part of the GeantV project. Results of preliminary performance evaluation and physics validation are presented as well.

  11. Space Earthquake Perturbation Simulation (SEPS) an application based on Geant4 tools to model and simulate the interaction between the Earthquake and the particle trapped on the Van Allen belt

    Science.gov (United States)

    Ambroglini, Filippo; Jerome Burger, William; Battiston, Roberto; Vitale, Vincenzo; Zhang, Yu

    2014-05-01

    During last decades, few space experiments revealed anomalous bursts of charged particles, mainly electrons with energy larger than few MeV. A possible source of these bursts are the low-frequency seismo-electromagnetic emissions, which can cause the precipitation of the electrons from the lower boundary of their inner belt. Studies of these bursts reported also a short-term pre-seismic excess. Starting from simulation tools traditionally used on high energy physics we developed a dedicated application SEPS (Space Perturbation Earthquake Simulation), based on the Geant4 tool and PLANETOCOSMICS program, able to model and simulate the electromagnetic interaction between the earthquake and the particles trapped in the inner Van Allen belt. With SEPS one can study the transport of particles trapped in the Van Allen belts through the Earth's magnetic field also taking into account possible interactions with the Earth's atmosphere. SEPS provides the possibility of: testing different models of interaction between electromagnetic waves and trapped particles, defining the mechanism of interaction as also shaping the area in which this takes place,assessing the effects of perturbations in the magnetic field on the particles path, performing back-tracking analysis and also modelling the interaction with electric fields. SEPS is in advanced development stage, so that it could be already exploited to test in details the results of correlation analysis between particle bursts and earthquakes based on NOAA and SAMPEX data. The test was performed both with a full simulation analysis, (tracing from the position of the earthquake and going to see if there were paths compatible with the burst revealed) and with a back-tracking analysis (tracing from the burst detection point and checking the compatibility with the position of associated earthquake).

  12. Preliminary assessment of Geant4 HP models and cross section libraries by reactor criticality benchmark calculations

    DEFF Research Database (Denmark)

    Cai, Xiao-Xiao; Llamas-Jansa, Isabel; Mullet, Steven

    2013-01-01

    to reactor modelling. Before version 9.5, Geant4 HP thermal scattering model (i.e. the S(α; β) model ) supports only three bounded isotopes, namely, H in water and polyethylene, and C in graphite. Newly supported materials include D in heavy water, O and Be in beryllium oxide, H and Zr in zirconium hydride......, U and O in uranium dioxide, Al metal, Be metal, and Fe metal. The native HP cross section library G4NDL does not include data for elements with atomic number larger than 92. Therefore, transuranic elements, which have impacts for a realistic reactor, can not be simulated by the combination of the HP...

  13. Geant4 simulation of optical photon transport in scintillator tile with direct readout by silicon photomultiplier

    Science.gov (United States)

    Korpachev, S.; Chadeeva, M.

    2017-01-01

    The direct coupling of silicon photomultiplier to the scintillator tile is considered to be the main option for active elements of the highly granular hadron calorimeter developed for future linear collider experiments. In this study, the response of the scintillator-SiPM system to minimum ionising particles was simulated using the optical photon transport functionality available in the Geant4 package. The uniformity of response for both flat tile and tile with dimple was estimated from the simulations and compared to the experimental results obtained in the previous studies.

  14. Study of silicon+6LiF thermal neutron detectors: GEANT4 simulations versus real data

    Science.gov (United States)

    Meo, S. Lo; Cosentino, L.; Mazzone, A.; Bartolomei, P.; Finocchiaro, P.

    2017-09-01

    Research and development on alternative thermal neutron detection technologies and methods are nowadays needed as a possible replacement of 3He-based ones. Commercial solid state silicon detectors, coupled with neutron converter layers containing 6Li, have been proved to represent a viable solution for several applications as present in the literature. In order to better understand the detailed operation and the response and efficiency of such detectors, a series of dedicated GEANT4 simulations were performed and compared with real data collected in a few different configurations. The results show an excellent agreement between data and simulations, indicating that the behavior of the detector is fully understood.

  15. Simulation and modeling for the stand-off radiation detection system (SORDS) using GEANT4

    Energy Technology Data Exchange (ETDEWEB)

    Hoover, Andrew S [Los Alamos National Laboratory; Wallace, Mark [Los Alamos National Laboratory; Galassi, Mark [Los Alamos National Laboratory; Mocko, Michal [Los Alamos National Laboratory; Palmer, David [Los Alamos National Laboratory; Schultz, Larry [Los Alamos National Laboratory; Tornga, Shawn [Los Alamos National Laboratory

    2009-01-01

    A Stand-Off Radiation Detection System (SORDS) is being developed through a joint effort by Raytheon, Los Alamos National Laboratory, Bubble Technology Industries, Radiation Monitoring Devices, and the Massachusetts Institute of Technology, for the Domestic Nuclear Detection Office (DNDO). The system is a mobile truck-based platform performing detection, imaging, and spectroscopic identification of gamma-ray sources. A Tri-Modal Imaging (TMI) approach combines active-mask coded aperture imaging, Compton imaging, and shadow imaging techniques. Monte Carlo simulation and modeling using the GEANT4 toolkit was used to generate realistic data for the development of imaging algorithms and associated software code.

  16. GEANT4 simulation and evaluation of a time-of-flight spectrometer for nuclear cross section measurements in particle therapy

    Energy Technology Data Exchange (ETDEWEB)

    Gruenwald, Oxana

    2011-06-08

    In 2007 a new project has been launched in a cooperation between the RWTH Aachen Physics Department, the University Hospital Aachen and the Philips Research Laboratories. The project aim is to validate and improve GEANT4 nuclear interaction models for use in proton and ion therapy. The method chosen here is the measurement of nuclear reaction cross sections which will not only provide a comparison to the simulation but will also allow to improve some of the parameters in the nuclear models. In the first phase of the project 200 MeV protons are used as a projectile in combination with a thin graphite target. For use in particle therapy the excitation functions of the most frequently produced isotopes need to be measured with an accuracy of 10% or less. For this purpose a dedicated detector system has been designed and implemented in GEANT4. The detection of target fragments produced by protons in graphite is achieved via time-of-flight spectrometry. In the setup presented here the primary beam first hits the Start detector and initiates the time-of-flight measurement before it passes through the apertures of two Veto detectors and impinges on the target. Successively, the secondary particles emanating from the target travel a short distance of 70/80 cm through vacuum (0.1 mbar) before they hit one of the 20 Stop detectors which end the time-of-flight measurement and record the energy deposited by the particle. The dissertation at hand describes the underlying detector concept and presents a detailed GEANT4 simulation of the setup which allows to evaluate the detector performance with respect to target fragment identification at a projectile energy of 200 MeV. At first, correlations of time-of-flight and energy deposition are built from simulated data and are subsequently used to reconstruct mass spectra of the detected fragments. Such influences on the detection performance as the target thickness, the residual pressure within the detector chamber, the Veto system

  17. Benchmarking nuclear models of FLUKA and GEANT4 for carbon ion therapy

    Energy Technology Data Exchange (ETDEWEB)

    Boehlen, T T; Cerutti, F; Dosanjh, M; Ferrari, A [European Organization for Nuclear Research CERN, CH-1211, Geneva 23 (Switzerland); Gudowska, I [Medical Radiation Physics, Karolinska Institutet and Stockholm University, Box 260 S-171 76 Stockholm (Sweden); Mairani, A [INFN Milan, Via Celoria 16, 20133 Milan (Italy); Quesada, J M, E-mail: Till.Tobias.Boehlen@cern.c [Departamento de Fisica Atomica, Molecular y Nuclear, Universidad de Sevilla (Spain)

    2010-10-07

    As carbon ions, at therapeutic energies, penetrate tissue, they undergo inelastic nuclear reactions and give rise to significant yields of secondary fragment fluences. Therefore, an accurate prediction of these fluences resulting from the primary carbon interactions is necessary in the patient's body in order to precisely simulate the spatial dose distribution and the resulting biological effect. In this paper, the performance of nuclear fragmentation models of the Monte Carlo transport codes, FLUKA and GEANT4, in tissue-like media and for an energy regime relevant for therapeutic carbon ions is investigated. The ability of these Monte Carlo codes to reproduce experimental data of charge-changing cross sections and integral and differential yields of secondary charged fragments is evaluated. For the fragment yields, the main focus is on the consideration of experimental approximations and uncertainties such as the energy measurement by time-of-flight. For GEANT4, the hadronic models G4BinaryLightIonReaction and G4QMD are benchmarked together with some recently enhanced de-excitation models. For non-differential quantities, discrepancies of some tens of percent are found for both codes. For differential quantities, even larger deviations are found. Implications of these findings for the therapeutic use of carbon ions are discussed.

  18. Modeling the relativistic runaway electron avalanche and the feedback mechanism with GEANT4

    CERN Document Server

    Skeltved, Alexander Broberg; Carlson, Brant; Gjesteland, Thomas; Celestin, Sebastien

    2016-01-01

    This paper presents the first study that uses the GEometry ANd Tracking 4 (GEANT4) toolkit to do quantitative comparisons with other modelling results related to the production of Terrestrial Gamma-ray Flashes (TGFs) and high-energy particle emission from thunderstorms. We will study the Relativistic Runaway Electron Avalanche (RREA) and the relativistic feedback process, as well as the production of bremsstrahlung photons from Runaway Electrons (REs). The Monte Carlo (MC) simulations take into account the effects of electron ionisation, electron by electron (M{\\o}ller) and electron by positron (Bhabha) scattering as well as the bremsstrahlung process and pair-production, in the $250$ eV$-100$ GeV energy range. Our results indicate that the multiplication of electrons during the development of RREAs and under the influence of feedback, are consistent with previous estimates. This is important to validate GEANT4 as a tool to model RREAs and feedback in homogeneous electric fields. We also determine the ratio o...

  19. Comparisons of hadrontherapy-relevant data to nuclear interaction codes in the Geant4 toolkit

    Science.gov (United States)

    Braunn, B.; Boudard, A.; Colin, J.; Cugnon, J.; Cussol, D.; David, J. C.; Kaitaniemi, P.; Labalme, M.; Leray, S.; Mancusi, D.

    2013-03-01

    Comparisons between experimental data, INCL and other nuclear models available in the Geant4 toolkit are presented. The data used for the comparisons come from a fragmentation experiment realised at GANIL facility. The main purpose of this experiment was to measure production rates and angular distributions of emitted particles from the collision of a 95.A MeV 12C beam and thick PMMA (plastic) targets. The latest version of the Intra Nuclear Cascade of Liege code extended to nucleus-nucleus collisions for ion beam therapy application will be described. This code as well as JQMD and the Geant4 binary cascade has been compared with these hadrontherapy-oriented experimental data. The results from the comparisons exhibit an overall qualitative agreement between the models and the experimental data. However, at a quantitative level, it has been shown that none of this three models manage to reproduce precisely all the data. The nucleus-nucleus extension of INCL, which is not predictive enough for ion beam therapy application yet, has nevertheless proven to be competitive with other nuclear collisions codes.

  20. Geant4 studies of the CNAO facility system for hadrontherapy treatment of uveal melanomas

    Science.gov (United States)

    Rimoldi, A.; Piersimoni, P.; Pirola, M.; Riccardi, C.

    2014-06-01

    The Italian National Centre of Hadrontherapy for Cancer Treatment (CNAO -Centro Nazionale di Adroterapia Oncologica) in Pavia, Italy, has started the treatment of selected cancers with the first patients in late 2011. In the coming months at CNAO plans are to activate a new dedicated treatment line for irradiation of uveal melanomas using the available active beam scan. The beam characteristics and the experimental setup should be tuned in order to reach the necessary precision required for such treatments. Collaboration between CNAO foundation, University of Pavia and INFN has started in 2011 to study the feasibility of these specialised treatments by implementing a MC simulation of the transport beam line and comparing the obtained simulation results with measurements at CNAO. The goal is to optimise an eye-dedicated transport beam line and to find the best conditions for ocular melanoma irradiations. This paper describes the Geant4 toolkit simulation of the CNAO setup as well as a modelised human eye with a tumour inside. The Geant4 application could be also used to test possible treatment planning systems. Simulation results illustrate the possibility to adapt the CNAO standard transport beam line by optimising the position of the isocentre and the addition of some passive elements to better shape the beam for this dedicated study.

  1. Carbon fragmentation measurements and validation of the Geant4 nuclear reaction models for hadrontherapy

    Science.gov (United States)

    De Napoli, M.; Agodi, C.; Battistoni, G.; Blancato, A. A.; Cirrone, G. A. P.; Cuttone, G.; Giacoppo, F.; Morone, M. C.; Nicolosi, D.; Pandola, L.; Patera, V.; Raciti, G.; Rapisarda, E.; Romano, F.; Sardina, D.; Sarti, A.; Sciubba, A.; Scuderi, V.; Sfienti, C.; Tropea, S.

    2012-11-01

    Nuclear fragmentation measurements are necessary when using heavy-ion beams in hadrontherapy to predict the effects of the ion nuclear interactions within the human body. Moreover, they are also fundamental to validate and improve the Monte Carlo codes for their use in planning tumor treatments. Nowadays, a very limited set of carbon fragmentation cross sections are being measured, and in particular, to our knowledge, no double-differential fragmentation cross sections at intermediate energies are available in the literature. In this work, we have measured the double-differential cross sections and the angular distributions of the secondary fragments produced in the 12C fragmentation at 62 A MeV on a thin carbon target. The experimental data have been used to benchmark the prediction capability of the Geant4 Monte Carlo code at intermediate energies, where it was never tested before. In particular, we have compared the experimental data with the predictions of two Geant4 nuclear reaction models: the Binary Light Ions Cascade and the Quantum Molecular Dynamic. From the comparison, it has been observed that the Binary Light Ions Cascade approximates the angular distributions of the fragment production cross sections better than the Quantum Molecular Dynamic model. However, the discrepancies observed between the experimental data and the Monte Carlo simulations lead to the conclusion that the prediction capability of both models needs to be improved at intermediate energies.

  2. Proton and electron deep dose profiles for retinoblastoma based on GEANT 4 code

    Energy Technology Data Exchange (ETDEWEB)

    Braga, Flavia V., E-mail: flaviafisica@gmail.co [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Programa de Pos-graduacao em Ciencias e Tecnicas Nucleares; Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Campos, Tarcisio P.R. de [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Programa de Pos-graduacao em Ciencias e Tecnicas Nucleares; Ribeiro, Kilder L., E-mail: kilderlr@gmail.co [Universidade Estadual de Feira de Santana (UEFS), BA (Brazil). Dept. de Fisica

    2009-07-01

    Herein, the dosimetry responses to a retinoblastoma proton and electron radiation therapy were investigated. The computational tool applied to this simulation was the Geant4 code, version 4.9.1. The code allows simulating the charge particle interaction with eyeball tissue. In the present simulation, a box of 4 cm side water filled had represented the human eye. The simulation was performed considering mono energetic beams of protons and electrons with spectra of 57 to 70 MeV for protons and 2 to 8 MeV for electrons. The simulation was guide by the advanced hadron therapy example distributed with the Geant4 code. The phantom was divided in voxels with 0.2 mm side. The energy deposited in each voxel was evaluated taken the direct beam at one face. The simulation results show the delivery energy and therefore the dose deposited in each voxel. The deep dose profiles to proton and electron were plotted. The well known Bragg peak was reproduced for protons. The maximum delivered dose defined the position at the proton stopped. However, to electrons, the absorbed energies were delivered along its path producing a more continuous distribution following the water depth, but also being stopped in the end of its path. (author)

  3. GMC: a GPU implementation of a Monte Carlo dose calculation based on Geant4.

    Science.gov (United States)

    Jahnke, Lennart; Fleckenstein, Jens; Wenz, Frederik; Hesser, Jürgen

    2012-03-07

    We present a GPU implementation called GMC (GPU Monte Carlo) of the low energy (CUDA programming interface. The classes for electron and photon interactions as well as a new parallel particle transport engine were implemented. The way a particle is processed is not in a history by history manner but rather by an interaction by interaction method. Every history is divided into steps that are then calculated in parallel by different kernels. The geometry package is currently limited to voxelized geometries. A modified parallel Mersenne twister was used to generate random numbers and a random number repetition method on the GPU was introduced. All phantom results showed a very good agreement between GPU and CPU simulation with gamma indices of >97.5% for a 2%/2 mm gamma criteria. The mean acceleration on one GTX 580 for all cases compared to Geant4 on one CPU core was 4860. The mean number of histories per millisecond on the GPU for all cases was 658 leading to a total simulation time for one intensity-modulated radiation therapy dose distribution of 349 s. In conclusion, Geant4-based Monte Carlo dose calculations were significantly accelerated on the GPU.

  4. Modelling PET radionuclide production in tissue and external targets using Geant4

    Science.gov (United States)

    Amin, T.; Infantino, A.; Lindsay, C.; Barlow, R.; Hoehr, C.

    2017-07-01

    The Proton Therapy Facility in TRIUMF provides 74 MeV protons extracted from a 500 MeV H- cyclotron for ocular melanoma treatments. During treatment, positron emitting radionuclides such as 1C, 15O and 13N are produced in patient tissue. Using PET scanners, the isotopic activity distribution can be measured for in-vivo range verification. A second cyclotron, the TR13, provides 13 MeV protons onto liquid targets for the production of PET radionuclides such as 18F, 13N or 68Ga, for medical applications. The aim of this work was to validate Geant4 against FLUKA and experimental measurements for production of the above-mentioned isotopes using the two cyclotrons. The results show variable degrees of agreement. For proton therapy, the proton-range agreement was within 2 mm for 11C activity, whereas 13N disagreed. For liquid targets at the TR13 the average absolute deviation ratio between FLUKA and experiment was 1.9±2.7, whereas the average absolute deviation ratio between Geant4 and experiment was 0. 6±0.4. This is due to the uncertainties present in experimentally determined reaction cross sections.

  5. A Compton camera application for the GAMOS GEANT4-based framework

    Energy Technology Data Exchange (ETDEWEB)

    Harkness, L.J., E-mail: ljh@ns.ph.liv.ac.uk [Oliver Lodge Laboratory, The University of Liverpool, Liverpool L69 7ZE (United Kingdom); Arce, P. [Department of Basic Research, CIEMAT, Madrid (Spain); Judson, D.S.; Boston, A.J.; Boston, H.C.; Cresswell, J.R.; Dormand, J.; Jones, M.; Nolan, P.J.; Sampson, J.A.; Scraggs, D.P.; Sweeney, A. [Oliver Lodge Laboratory, The University of Liverpool, Liverpool L69 7ZE (United Kingdom); Lazarus, I.; Simpson, J. [STFC Daresbury Laboratory, Daresbury, Warrington WA4 4AD (United Kingdom)

    2012-04-11

    Compton camera systems can be used to image sources of gamma radiation in a variety of applications such as nuclear medicine, homeland security and nuclear decommissioning. To locate gamma-ray sources, a Compton camera employs electronic collimation, utilising Compton kinematics to reconstruct the paths of gamma rays which interact within the detectors. The main benefit of this technique is the ability to accurately identify and locate sources of gamma radiation within a wide field of view, vastly improving the efficiency and specificity over existing devices. Potential advantages of this imaging technique, along with advances in detector technology, have brought about a rapidly expanding area of research into the optimisation of Compton camera systems, which relies on significant input from Monte-Carlo simulations. In this paper, the functionality of a Compton camera application that has been integrated into GAMOS, the GEANT4-based Architecture for Medicine-Oriented Simulations, is described. The application simplifies the use of GEANT4 for Monte-Carlo investigations by employing a script based language and plug-in technology. To demonstrate the use of the Compton camera application, simulated data have been generated using the GAMOS application and acquired through experiment for a preliminary validation, using a Compton camera configured with double sided high purity germanium strip detectors. Energy spectra and reconstructed images for the data sets are presented.

  6. The study of response of wide band gap semiconductor detectors using the Geant4

    Directory of Open Access Journals (Sweden)

    Hussain Riaz

    2014-01-01

    Full Text Available The energy dependence on the intrinsic efficiency, absolute efficiency, full energy peak absolute efficiency and peak-to-total ratio have been studied for various wide band gap semiconductor detectors using the Geant4 based Monte Carlo simulations. The detector thickness of 1-4 mm and the area in 16-100 mm2 range were considered in this work. In excellent agreement with earlier work (Rybka et al., [20], the Geant4 simulated values of detector efficiencies have been found to decrease with incident g-ray energy. Both for the detector thickness and the detector area, the increasing trends have been observed for total efficiency as well as for full-energy peak efficiency in 0.1 MeV-50 MeV range. For Cd1-xZnxTe, the detector response remained insensitive to changes in relative proportions of Zn. For various wide band gap detectors studied in this work, the detection efficiency of TlBr was found highest over the entire range of energy, followed by the HgI2, CdTe, and then by CZT.

  7. Geant4 Simulation of A Multi-layered target for the Study of Neutron-Unbound Nuclei

    Science.gov (United States)

    Gueye, Paul; Freeman, Jessica; Frank, Nathan; Thoennessen, Michael; MONA Collaboration

    2013-10-01

    The MoNA/LISA setup at the National Superconducting Cyclotron Laboratory at Michigan State University has provided an avenue to study the nuclear structure of unbound states/nuclei at and beyond the neutron dripline for the past decade using secondary beams from the Coupled Cyclotron Facility. A new multi-layered Si/Be active target is being designed to specifically study neutron-unbound nuclei. In these experiments the decay energy is reconstructed from fragment-neutron coincidence measurements that are typically low in count rate. The multi-layered target will allow the use of thicker targets to increase the reaction rates, thus enabling to study currently out of reach nuclei such as 21C, 23C and 24N. The Geant4 Monte Carlo toolkit is currently used to model these physics processes within the multi-layered target and expected invariant mass distributions. A description of the experimental setup and simulation work will be discussed. This work is supported by the Department of Energy National Nuclear Security Administration under Award Number DE-NA0000979.

  8. A quantitative study of the 6NM-64 neutron monitor by using Geant4: 1. Detection efficiency for different particles

    Energy Technology Data Exchange (ETDEWEB)

    Paschalis, P. [Nuclear and Particle Physics Section, Physics Department, National and Kapodistrian University of Athens, Zografos 15783, Athens (Greece); Mavromichalaki, H., E-mail: emavromi@phys.uoa.gr [Nuclear and Particle Physics Section, Physics Department, National and Kapodistrian University of Athens, Zografos 15783, Athens (Greece); Dorman, L.I. [Israel Cosmic Ray and Space Weather Centre and Emilio Ségre Observatory, Affiliated to Tel Aviv University, Golan Research Institute, and Israel Space Agency, Qazrin 12900 (Israel); Cosmic Ray Department of N.V. Pushkov IZMIRAN, Russian Academy of Science, Troitsk 142190, Moscow (Russian Federation)

    2013-11-21

    The neutron monitors are the ground based detectors that continuously measure the flow of the cosmic rays that reach the earth′s surface. The measurements of the neutron monitors are of great importance for the scientific community since they contribute to the study of several scientific fields, such as the solar activity and the prediction of the space weather. For this reason, most of the neutron monitors worldwide are organized in a network, in order for their measurements to be easily accessible. The correct evaluation of the measurements and their connection with the physical quantities of the cosmic rays require the knowledge of the interactions and the detection procedure that take place inside the neutron monitor. In this work a quantitative study of the 6NM-64 behavior is presented based on Monte Carlo simulations by using the well known Geant4 simulations toolkit. The study focuses on the detection efficiency of the neutron monitor, both in sections and as a whole for the different particle species, on its dependence on the incident direction of the particles and on the secondary neutrons produced inside the neutron monitor.

  9. Absorbed dose estimations of 131I for critical organs using the GEANT4 Monte Carlo simulation code

    Institute of Scientific and Technical Information of China (English)

    Ziaur Rahman; Shakeel ur Rehman; Waheed Arshed; Nasir M Mirza; Abdul Rashid; Jahan Zeb

    2012-01-01

    The aim of this study is to compare the absorbed doses of critical organs of 131I using the MIRD (Medical Internal Radiation Dose) with the corresponding predictions made by GEANT4 simulations.S-values (mean absorbed dose rate per unit activity) and energy deposition per decay for critical organs of 131I for various ages,using standard cylindrical phantom comprising water and ICRP soft-tissue material,have also been estimated.In this study the effect of volume reduction of thyroid,during radiation therapy,on the calculation of absorbed dose is also being estimated using GEANT4.Photon specific energy deposition in the other organs of the neck,due to 131I decay in the thyroid organ,has also been estimated.The maximum relative difference of MIRD with the GEANT4 simulated results is 5.64% for an adult's critical organs of 131I.Excellent agreement was found between the results of water and ICRP soft tissue using the cylindrical model.S-values are tabulated for critical organs of 131I,using 1,5,10,15 and 18 years (adults) individuals.S-values for a cylindrical thyroid of different sizes,having 3.07% relative differences of GEANT4 with Siegel & Stabin results.Comparison of the experimentally measured values at 0.5 and 1 m away from neck of the ionization chamber with GEANT4 based Monte Carlo simulations results show good agreement.This study shows that GEANT4 code is an important tool for the internal dosimetry calculations.

  10. Geant4 Simulation Study of Deep Underground Muons: Vertical Intensity and Angular Distribution

    Directory of Open Access Journals (Sweden)

    Halil Arslan

    2013-01-01

    Full Text Available Underground muon intensities up to 10000 m.w.e. and angular distribution up to 6500 m.w.e. in standard rock have been investigated using Geant4 simulation package. Muons with energies above 100 GeV were distributed from the ground level taking into account the muon charge ratio of ~1.3 at sea level. The simulated differential muon intensities are in good agreement with the intensities given in the literature. Furthermore, the simulation results for the integrated intensities are consistent with the experimental data, particularly at depths above 4000 m.w.e., where the simulation gives slightly smaller intensities than the experimental ones. In addition, the simulated exponent n at different underground depths agrees well with the experimental points, especially above ~2000 m.w.e.

  11. Geant4 simulation of the nTOF-EAR2 neutron beam: Characteristics and prospects

    Energy Technology Data Exchange (ETDEWEB)

    Lerendegui-Marco, J.; Guerrero, C.; Cortes-Giraldo, M.A.; Quesada, J.M. [Universidad de Sevilla, Dpto. de Fisica Atomica, Molecular y Nuclear, Sevilla (Spain); Lo Meo, S. [Research Centre ' ' Ezio Clementel' ' , ENEA, Bologna (Italy); INFN, Section of Bologna, Bologna (Italy); Massimi, C.; Vannini, G. [INFN, Section of Bologna, Bologna (Italy); University of Bologna, Physics and Astronomy Dept. ' ' Alma Mater Studiorum' ' , Bologna (Italy); Barbagallo, M.; Colonna, N. [INFN, Section of Bari, Bari (Italy); Mancusi, D.; Vlachoudis, V. [CEA-Saclay, Gif-sur-Yvette (France); Mingrone, F. [INFN, Section of Bologna, Bologna (Italy); Sabate-Gilarte, M. [Universidad de Sevilla, Dpto. de Fisica Atomica, Molecular y Nuclear, Sevilla (Spain); CEA-Saclay, Gif-sur-Yvette (France); Collaboration: nTOF Collaboration

    2016-04-15

    The characteristics of the neutron beam at the new nTOF-EAR2 facility have been simulated with the Geant4 code with the aim of providing useful data for both the analysis and planning of the upcoming measurements. The spatial and energy distributions of the neutrons, the resolution function and the in-beam γ-ray background have been studied in detail and their implications in the forthcoming experiments have been discussed. The results confirm that, with this new short (18.5 m flight path) beam line, reaching an instantaneous neutron flux beyond 10{sup 5} n/μs/pulse in the keV region, nTOF is one of the few facilities where challenging measurements can be performed, involving in particular short-lived radioisotopes. (orig.)

  12. Signal pulse emulation for scintillation detectors using Geant4 Monte Carlo with light tracking simulation

    Energy Technology Data Exchange (ETDEWEB)

    Ogawara, R. [Department of Medical Physics and Engineering, Graduate School of Medicine, Hokkaido University, Kita-15 Nishi-7, Kita-ku, Sapporo-shi, Hokkaido (Japan); Ishikawa, M., E-mail: masayori@med.hokudai.ac.jp [Graduate School of Health Science, Hokkaido University, Kita-12 Nishi-5, Kita-ku, Sapporo-shi, Hokkaido (Japan)

    2016-07-15

    The anode pulse of a photomultiplier tube (PMT) coupled with a scintillator is used for pulse shape discrimination (PSD) analysis. We have developed a novel emulation technique for the PMT anode pulse based on optical photon transport and a PMT response function. The photon transport was calculated using Geant4 Monte Carlo code and the response function with a BC408 organic scintillator. The obtained percentage RMS value of the difference between the measured and simulated pulse with suitable scintillation properties using GSO:Ce (0.4, 1.0, 1.5 mol%), LaBr{sub 3}:Ce and BGO scintillators were 2.41%, 2.58%, 2.16%, 2.01%, and 3.32%, respectively. The proposed technique demonstrates high reproducibility of the measured pulse and can be applied to simulation studies of various radiation measurements.

  13. Distributed Geant4 simulation in medical and space science applications using DIANE framework and the GRID

    CERN Document Server

    Moscicki, J T; Mantero, A; Pia, M G

    2003-01-01

    Distributed computing is one of the most important trends in IT which has recently gained significance for large-scale scientific applications. Distributed analysis environment (DIANE) is a R&D study, focusing on semiinteractive parallel and remote data analysis and simulation, which has been conducted at CERN. DIANE provides necessary software infrastructure for parallel scientific applications in the master-worker model. Advanced error recovery policies, automatic book-keeping of distributed jobs and on-line monitoring and control tools are provided. DIANE makes a transparent use of a number of different middleware implementations such as load balancing service (LSF, PBS, GRID Resource Broker, Condor) and security service (GSI, Kerberos, openssh). A number of distributed Geant 4 simulations have been deployed and tested, ranging from interactive radiotherapy treatment planning using dedicated clusters in hospitals, to globally-distributed simulations of astrophysics experiments using the European data g...

  14. Comparison of Geant4 multiple Coulomb scattering models with theory for radiotherapy protons

    CERN Document Server

    Makarova, Anastasia; Sauerwein, Wolfgang

    2016-01-01

    Usually, Monte Carlo models are validated against experimental data. However, models of multiple Coulomb scattering (MCS) in the Gaussian approximation are exceptional in that we have theories which are probably more accurate than the experiments which have, so far, been done to test them. In problems directly sensitive to the distribution of angles leaving the target, the relevant theory is the Moliere/Fano/Hanson variant of Moliere theory. For transverse spreading of the beam in the target itself, the theory of Preston and Koehler holds. Therefore, in this paper we compare Geant4 simulations, using the Urban and Wentzel models of MCS, with theory rather than experiment, revealing trends which would otherwise be obscured by experimental scatter. For medium-energy (radiotherapy) protons, and low-Z (water-like) target materials, Wentzel appears to be better than Urban in simulating the distribution of outgoing angles. For beam spreading in the target itself, the two models are essentially equal.

  15. Simulation loop between cad systems, GEANT-4 and GeoModel: Implementation and results

    Science.gov (United States)

    Sharmazanashvili, A.; Tsutskiridze, Niko

    2016-09-01

    Compare analysis of simulation and as-built geometry descriptions of detector is important field of study for data_vs_Monte-Carlo discrepancies. Shapes consistency and detalization is not important while adequateness of volumes and weights of detector components are essential for tracking. There are 2 main reasons of faults of geometry descriptions in simulation: (1) Difference between simulated and as-built geometry descriptions; (2) Internal inaccuracies of geometry transformations added by simulation software infrastructure itself. Georgian Engineering team developed hub on the base of CATIA platform and several tools enabling to read in CATIA different descriptions used by simulation packages, like XML->CATIA; VP1->CATIA; Geo-Model->CATIA; Geant4->CATIA. As a result it becomes possible to compare different descriptions with each other using the full power of CATIA and investigate both classes of reasons of faults of geometry descriptions. Paper represents results of case studies of ATLAS Coils and End-Cap toroid structures.

  16. Simulation Loop between CAD systems, Geant4 and GeoModel: Implementation and Results

    CERN Document Server

    Sharmazanashvili, Alexander; The ATLAS collaboration

    2015-01-01

    Data_vs_MonteCarlo discrepancy is one of the most important field of investigation for ATLAS simulation studies. There are several reasons of above mentioned discrepancies but primary interest is falling on geometry studies and investigation of how geometry descriptions of detector in simulation adequately representing “as-built” descriptions. Shapes consistency and detalization is not important while adequateness of volumes and weights of detector components are essential for tracking. There are 2 main reasons of faults of geometry descriptions in simulation: 1/ Inconsistency to “as-built” geometry descriptions; 2/Internal inaccuracies of transactions added by simulation packages itself. Georgian Engineering team developed hub on the base of CATIA platform and several tools enabling to read in CATIA different descriptions used by simulation packages, like XML/Persint->CATIA; IV/VP1->CATIA; GeoModel->CATIA; Geant4->CATIA. As a result it becomes possible to compare different descriptions with each othe...

  17. A comparison between Geant4 PIXE simulations and experimental data for standard reference samples

    Energy Technology Data Exchange (ETDEWEB)

    Francis, Z., E-mail: ziad.francis@gmail.com [Université Saint Joseph, Faculty of Science, Department of Physics, Beirut (Lebanon); The Open University, Faculty of Science, Department of Physical Sciences, Walton Hall, MK7 6AA Milton Keynes (United Kingdom); El Bast, M. [Ion Beam Analysis Laboratory, Lebanese Atomic Energy Commission, National Council for Scientific Research, Beirut (Lebanon); El Haddad, R. [Université Saint Joseph, Faculty of Science, Department of Mathematics, Beirut (Lebanon); Mantero, A. [Istituto Nazionale di Fisica Nucleare, sez. di Genova, via Dodecaneso 33, 16146 Genova (Italy); Incerti, S. [Université Bordeaux 1, CNRS/IN2P3, Centre d’Etudes Nucléaires de Bordeaux-Gradignan, CENBG, Chemin du Solarium, 33175 Gradignan (France); Ivanchenko, V. [Ecoanalytica, Moscow State University, 119899 Moscow (Russian Federation); Geant4 Associates International Ltd., Hebden Bridge (United Kingdom); El Bitar, Z. [Institut Pluridisciplinaire Hubert Curien, CNRS/IN2P3, 67037 Strasbourg Cedex (France); Champion, C. [Université Bordeaux 1, CNRS/IN2P3, Centre d’Etudes Nucléaires de Bordeaux-Gradignan, CENBG, Chemin du Solarium, 33175 Gradignan (France); Bernal, M.A. [Instituto de Física Gleb Wataghin, Universidade Estadual de Campinas-UNICAMP, SP 13083-859 (Brazil); Roumie, M. [Ion Beam Analysis Laboratory, Lebanese Atomic Energy Commission, National Council for Scientific Research, Beirut (Lebanon)

    2013-12-01

    The Geant4 PIXE de-excitation processes are used to simulate proton beam interactions with sample materials of known composition. Simulations involve four mono-elemental materials; Cu, Fe, Si and Al and three relatively complex materials: stainless steel, phosphor bronze and basal BE-N reference material composed of 25 different elements. The simulation results are compared to experimental spectra acquired for real samples analyzed using 3 MeV incident protons delivered by an ion tandem accelerator. Data acquisition was performed using a Si(Li) detector and an aluminum funny filter was added for the three last mentioned samples depending on the configuration to reduce the noise and obtain clear resulting spectrum. The results show a good agreement between simulations and measurements for the different samples.

  18. Geant4.10 simulation of geometric model for metaphase chromosome

    Energy Technology Data Exchange (ETDEWEB)

    Rafat-Motavalli, L., E-mail: rafat@um.ac.ir; Miri-Hakimabad, H.; Bakhtiyari, E.

    2016-04-01

    In this paper, a geometric model of metaphase chromosome is explained. The model is constructed according to the packing ratio and dimension of the structure from nucleosome up to chromosome. A B-DNA base pair is used to construct 200 base pairs of nucleosomes. Each chromatin fiber loop, which is the unit of repeat, has 49,200 bp. This geometry is entered in Geant4.10 Monte Carlo simulation toolkit and can be extended to the whole metaphase chromosomes and any application in which a DNA geometrical model is needed. The chromosome base pairs, chromosome length, and relative length of chromosomes are calculated. The calculated relative length is compared to the relative length of human chromosomes.

  19. Technical Note: Radiotherapy dose calculations using GEANT4 and the Amazon Elastic Compute Cloud

    CERN Document Server

    Poole, Christopher M; Trapp, Jamie V; Langton, Christian M

    2011-01-01

    Cloud computing allows for vast computational resources to be leveraged quickly and easily in bursts as and when required. Using the Amazon Elastic Compute Cloud and the Amazon Simple Storage Solution, we describe a technique that allows for Monte Carlo radiotherapy dose calculations to be performed using GEANT4 and executed in the cloud. Simulation cost and completion time was evaluated as a function of instance count using compute instances acquired via biding on the Elastic Compute Cloud spot market. Bidding for instances on the instance spot market was found to be 35-60% of the cost of on-demand instances of the same type. Using the technique, we demonstrate the potential usefulness of cloud computing as a solution for rapid Monte Carlo simulation for radiotherapy dose calculation.

  20. Geant4 calculations for space radiation shielding material Al2O3

    Science.gov (United States)

    Capali, Veli; Acar Yesil, Tolga; Kaya, Gokhan; Kaplan, Abdullah; Yavuz, Mustafa; Tilki, Tahir

    2015-07-01

    Aluminium Oxide, Al2O3 is the most widely used material in the engineering applications. It is significant aluminium metal, because of its hardness and as a refractory material owing to its high melting point. This material has several engineering applications in diverse fields such as, ballistic armour systems, wear components, electrical and electronic substrates, automotive parts, components for electric industry and aero-engine. As well, it is used as a dosimeter for radiation protection and therapy applications for its optically stimulated luminescence properties. In this study, stopping powers and penetrating distances have been calculated for the alpha, proton, electron and gamma particles in space radiation shielding material Al2O3 for incident energies 1 keV - 1 GeV using GEANT4 calculation code.

  1. Nuclear reaction measurements on tissue-equivalent materials and GEANT4 Monte Carlo simulations for hadrontherapy

    Science.gov (United States)

    De Napoli, M.; Romano, F.; D'Urso, D.; Licciardello, T.; Agodi, C.; Candiano, G.; Cappuzzello, F.; Cirrone, G. A. P.; Cuttone, G.; Musumarra, A.; Pandola, L.; Scuderi, V.

    2014-12-01

    When a carbon beam interacts with human tissues, many secondary fragments are produced into the tumor region and the surrounding healthy tissues. Therefore, in hadrontherapy precise dose calculations require Monte Carlo tools equipped with complex nuclear reaction models. To get realistic predictions, however, simulation codes must be validated against experimental results; the wider the dataset is, the more the models are finely tuned. Since no fragmentation data for tissue-equivalent materials at Fermi energies are available in literature, we measured secondary fragments produced by the interaction of a 55.6 MeV u-1 12C beam with thick muscle and cortical bone targets. Three reaction models used by the Geant4 Monte Carlo code, the Binary Light Ions Cascade, the Quantum Molecular Dynamic and the Liege Intranuclear Cascade, have been benchmarked against the collected data. In this work we present the experimental results and we discuss the predictive power of the above mentioned models.

  2. Monte Carlo Simulation of RPC-based PET with GEANT4

    CERN Document Server

    Weizheng, Zhou; Cheng, Li; Hongfang, Chen; Yongjie, Sun; Tianxiang, Chen

    2014-01-01

    The Resistive Plate Chambers (RPC) are low-cost charged-particle detectors with good timing resolution and potentially good spatial resolution. Using RPC as gamma detector provides an opportunity for application in positron emission tomography (PET). In this work, we use GEANT4 simulation package to study various methods improving the detection efficiency of a realistic RPC-based PET model for 511keV photons, by adding more detection units, changing the thickness of each layer, choosing different converters and using multi-gaps RPC (MRPC) technique. Proper balance among these factors are discussed. It's found that although RPC with materials of high atomic number can reach a higher efficiency, they may contribute to a poor spatial resolution and higher background level.

  3. ALGEBRA: ALgorithm for the heterogeneous dosimetry based on GEANT4 for BRAchytherapy.

    Science.gov (United States)

    Afsharpour, H; Landry, G; D'Amours, M; Enger, S; Reniers, B; Poon, E; Carrier, J-F; Verhaegen, F; Beaulieu, L

    2012-06-07

    Task group 43 (TG43)-based dosimetry algorithms are efficient for brachytherapy dose calculation in water. However, human tissues have chemical compositions and densities different than water. Moreover, the mutual shielding effect of seeds on each other (interseed attenuation) is neglected in the TG43-based dosimetry platforms. The scientific community has expressed the need for an accurate dosimetry platform in brachytherapy. The purpose of this paper is to present ALGEBRA, a Monte Carlo platform for dosimetry in brachytherapy which is sufficiently fast and accurate for clinical and research purposes. ALGEBRA is based on the GEANT4 Monte Carlo code and is capable of handling the DICOM RT standard to recreate a virtual model of the treated site. Here, the performance of ALGEBRA is presented for the special case of LDR brachytherapy in permanent prostate and breast seed implants. However, the algorithm is also capable of handling other treatments such as HDR brachytherapy.

  4. Geant4 based simulation of the Water Cherenkov Detectors of the LAGO Project

    CERN Document Server

    Calderón, R; Núñez, L A

    2015-01-01

    To characterize the signals registered by the different types of water Cherenkov detectors (WCD) used by the Latin American Giant Observatory (LAGO) Project, it is necessary to develop detailed simulations of the detector response to the flux of secondary particles at the detector level. These particles are originated during the interaction of cosmic rays with the atmosphere. In this context, the LAGO project aims to study the high energy component of gamma rays bursts (GRBs) and space weather phenomena by looking for the solar modulation of galactic cosmic rays (GCRs). Focus in this, a complete and complex chain of simulations is being developed that account for geomagnetic effects, atmospheric reaction and detector response at each LAGO site. In this work we shown the first steps of a GEANT4 based simulation for the LAGO WCD, with emphasis on the induced effects of the detector internal diffusive coating.

  5. Geant4 calculations for space radiation shielding material Al2O3

    Directory of Open Access Journals (Sweden)

    Capali Veli

    2015-01-01

    Full Text Available Aluminium Oxide, Al2O3 is the most widely used material in the engineering applications. It is significant aluminium metal, because of its hardness and as a refractory material owing to its high melting point. This material has several engineering applications in diverse fields such as, ballistic armour systems, wear components, electrical and electronic substrates, automotive parts, components for electric industry and aero-engine. As well, it is used as a dosimeter for radiation protection and therapy applications for its optically stimulated luminescence properties. In this study, stopping powers and penetrating distances have been calculated for the alpha, proton, electron and gamma particles in space radiation shielding material Al2O3 for incident energies 1 keV – 1 GeV using GEANT4 calculation code.

  6. TileCal Beam Test Simulation Application in the FADS/Goofy Framework (GEANT4)

    CERN Document Server

    Solodkov, A A

    2003-01-01

    A new application for the Tile Calorimeter (TileCal) beam test simulation has been developed in GEANT4 within the FADS/Goofy framework. The geometry and readout systems for all the different TileCal modules have been implemented in a quite detailed way. This application allows to simulate all the TileCal beam test setup configurations existing so far. Details of the development as well as instructions to install and run the program are presented. The first tests have been performed for a beam test setup consisting of five prototype modules using negative pions with different energies and results of comparison to the experimental data from TileCal TDR are presented as well.

  7. Performance of Geant4 in simulating semiconductor particle detector response in the energy range below 1 MeV

    CERN Document Server

    Soti, G.; Breitenfeldt, M.; Finlay, P.; Kraev, I.S.; Knecht, A.; Porobic, T.; Zákoucký, D.; Severijns, N.

    2013-01-01

    Geant4 simulations play a crucial role in the analysis and interpretation of experiments providing low energy precision tests of the Standard Model. This paper focuses on the accuracy of the description of the electron processes in the energy range between 100 and 1000 keV. The effect of the different simulation parameters and multiple scattering models on the backscattering coefficients is investigated. Simulations of the response of HPGe and passivated implanted planar Si detectors to \\beta{} particles are compared to experimental results. An overall good agreement is found between Geant4 simulations and experimental data.

  8. Molecular scale track structure simulations in liquid water using the Geant4-DNA Monte-Carlo processes

    Energy Technology Data Exchange (ETDEWEB)

    Francis, Z., E-mail: ziad.francis@gmail.co [Institut de Radioprotection et de Surete Nucleaire, Laboratoire de Dosimetrie des Rayonnements Ionisants, BP 17, 92262 Fontenay-aux-Roses Cedex (France); Incerti, S. [Universite Bordeaux 1, CNRS/IN2P3, Centre d' Etudes Nucleaires de Bordeaux Gradignan, CENBG, Chemin du Solarium, BP120, 33175 Gradignan (France); Capra, R. [Via Niella 12, 17100 Savona (Italy); Mascialino, B. [Department of Medical Radiation Physics, Stockholm University, Box 260, 17176 Stockholm (Sweden); Montarou, G. [Laboratoire de Physique Corpusculaire, 24 avenue des Landais, 63177 Aubiere (France); Stepan, V. [Nuclear Physics Institute ASCR, Na Truhlarce 39/64, Praha 8 (Czech Republic); Villagrasa, C. [Institut de Radioprotection et de Surete Nucleaire, Laboratoire de Dosimetrie des Rayonnements Ionisants, BP 17, 92262 Fontenay-aux-Roses Cedex (France)

    2011-01-15

    This paper presents a study of energy deposits induced by ionising particles in liquid water at the molecular scale. Particles track structures were generated using the Geant4-DNA processes of the Geant4 Monte-Carlo toolkit. These processes cover electrons (0.025 eV-1 MeV), protons (1 keV-100 MeV), hydrogen atoms (1 keV-100 MeV) and alpha particles (10 keV-40 MeV) including their different charge states. Electron ranges and lineal energies for protons were calculated in nanometric and micrometric volumes.

  9. Efficiency transfer using the GEANT4 code of CERN for HPGe gamma spectrometry.

    Science.gov (United States)

    Chagren, S; Ben Tekaya, M; Reguigui, N; Gharbi, F

    2016-01-01

    In this work we apply the GEANT4 code of CERN to calculate the peak efficiency in High Pure Germanium (HPGe) gamma spectrometry using three different procedures. The first is a direct calculation. The second corresponds to the usual case of efficiency transfer between two different configurations at constant emission energy assuming a reference point detection configuration and the third, a new procedure, consists on the transfer of the peak efficiency between two detection configurations emitting the gamma ray in different energies assuming a "virtual" reference point detection configuration. No pre-optimization of the detector geometrical characteristics was performed before the transfer to test the ability of the efficiency transfer to reduce the effect of the ignorance on their real magnitude on the quality of the transferred efficiency. The obtained and measured efficiencies were found in good agreement for the two investigated methods of efficiency transfer. The obtained agreement proves that Monte Carlo method and especially the GEANT4 code constitute an efficient tool to obtain accurate detection efficiency values. The second investigated efficiency transfer procedure is useful to calibrate the HPGe gamma detector for any emission energy value for a voluminous source using one point source detection efficiency emitting in a different energy as a reference efficiency. The calculations preformed in this work were applied to the measurement exercise of the EUROMET428 project. A measurement exercise where an evaluation of the full energy peak efficiencies in the energy range 60-2000 keV for a typical coaxial p-type HpGe detector and several types of source configuration: point sources located at various distances from the detector and a cylindrical box containing three matrices was performed.

  10. GATE - Geant4 Application for Tomographic Emission: a simulation toolkit for PET and SPECT

    Science.gov (United States)

    Jan, S.; Santin, G.; Strul, D.; Staelens, S.; Assié, K.; Autret, D.; Avner, S.; Barbier, R.; Bardiès, M.; Bloomfield, P. M.; Brasse, D.; Breton, V.; Bruyndonckx, P.; Buvat, I.; Chatziioannou, A. F.; Choi, Y.; Chung, Y. H.; Comtat, C.; Donnarieix, D.; Ferrer, L.; Glick, S. J.; Groiselle, C. J.; Guez, D.; Honore, P.-F.; Kerhoas-Cavata, S.; Kirov, A. S.; Kohli, V.; Koole, M.; Krieguer, M.; van der Laan, D. J.; Lamare, F.; Largeron, G.; Lartizien, C.; Lazaro, D.; Maas, M. C.; Maigne, L.; Mayet, F.; Melot, F.; Merheb, C.; Pennacchio, E.; Perez, J.; Pietrzyk, U.; Rannou, F. R.; Rey, M.; Schaart, D. R.; Schmidtlein, C. R.; Simon, L.; Song, T. Y.; Vieira, J.-M.; Visvikis, D.; Van de Walle, R.; Wieërs, E.; Morel, C.

    2012-01-01

    Monte Carlo simulation is an essential tool in emission tomography that can assist in the design of new medical imaging devices, the optimization of acquisition protocols, and the development or assessment of image reconstruction algorithms and correction techniques. GATE, the Geant4 Application for Tomographic Emission, encapsulates the Geant4 libraries to achieve a modular, versatile, scripted simulation toolkit adapted to the field of nuclear medicine. In particular, GATE allows the description of time-dependent phenomena such as source or detector movement, and source decay kinetics. This feature makes it possible to simulate time curves under realistic acquisition conditions and to test dynamic reconstruction algorithms. This paper gives a detailed description of the design and development of GATE by the OpenGATE collaboration, whose continuing objective is to improve, document, and validate GATE by simulating commercially available imaging systems for PET and SPECT. Large effort is also invested in the ability and the flexibility to model novel detection systems or systems still under design. A public release of GATE licensed under the GNU Lesser General Public License can be downloaded at the address http://www-lphe.ep.ch/GATE/. Two benchmarks developed for PET and SPECT to test the installation of GATE and to serve as a tutorial for the users are presented. Extensive validation of the GATE simulation platform has been started, comparing simulations and measurements on commercially available acquisition systems. References to those results are listed. The future prospects toward the gridification of GATE and its extension to other domains such as dosimetry are also discussed. PMID:15552416

  11. Geant4-DNA simulations using complex DNA geometries generated by the DnaFabric tool

    Science.gov (United States)

    Meylan, S.; Vimont, U.; Incerti, S.; Clairand, I.; Villagrasa, C.

    2016-07-01

    Several DNA representations are used to study radio-induced complex DNA damages depending on the approach and the required level of granularity. Among all approaches, the mechanistic one requires the most resolved DNA models that can go down to atomistic DNA descriptions. The complexity of such DNA models make them hard to modify and adapt in order to take into account different biological conditions. The DnaFabric project was started to provide a tool to generate, visualise and modify such complex DNA models. In the current version of DnaFabric, the models can be exported to the Geant4 code to be used as targets in the Monte Carlo simulation. In this work, the project was used to generate two DNA fibre models corresponding to two DNA compaction levels representing the hetero and the euchromatin. The fibres were imported in a Geant4 application where computations were performed to estimate the influence of the DNA compaction on the amount of calculated DNA damage. The relative difference of the DNA damage computed in the two fibres for the same number of projectiles was found to be constant and equal to 1.3 for the considered primary particles (protons from 300 keV to 50 MeV). However, if only the tracks hitting the DNA target are taken into account, then the relative difference is more important for low energies and decreases to reach zero around 10 MeV. The computations were performed with models that contain up to 18,000 DNA nucleotide pairs. Nevertheless, DnaFabric will be extended to manipulate multi-scale models that go from the molecular to the cellular levels.

  12. Electromagnetic momentum in frontiers of modern physics

    Institute of Scientific and Technical Information of China (English)

    Gianfranco SPAVIERI; Jesús ERAZO; Arturo SANCHEZ; Felix AGUIRRE; George T.GILLIES; Miguel RODRIGUEZ

    2008-01-01

    We review the role of the momentum of the electromagnetic (EM) fields Pe in several areas of modern physics.Pe represents the EM interaction in equations for matter and light waves propagation. As an application of wave propagation properties,a first order optical experiment which tests the speed of light in moving rarefied gases is presented.Within a classical context,the momentum Pe appears also in proposed tests of EM interactions involving open currents and angular momentum conservation laws.Moreover,Pe is the link to the unitary vision of the quantum effects of the Aharonov-Bohm (AB) type and,for several of these effects,the strength of Pe is evaluated.These effects provide a quantum approach to evaluate the limit of the photon mass mph.A new effect of the AB type,together with the scalar AB effect,provides the basis f0r table-top experiments which yield the limit mph=9.4×10-52g,a value that improves the results achieved with recent classical and quantum approaches.

  13. Characterization with GEANT4 of 16OMLCTM Siemens multi leaf collimator in a linear accelerator Siemens OncortM; Caracterizacion con GEANT4 colimador multilaminas siemenes 160-MLC{sup T}M en un acelerador lineal Siemens Oncor

    Energy Technology Data Exchange (ETDEWEB)

    Cortes Giraldo, M. A.; Miras, H.; Arrans, R.; Gallardo, M. I.; Quesada, J. M.

    2011-07-01

    The interest and motivation of this work lies in the ability to present GEANT4 to simulate neutron transport through the material, making it possible to make estimates of pollution existing neutron radiotherapy treatments to energies at which the neutron production is significant.

  14. Study of te evolution of the GEANT4 electrons transport algorithm to applications in radiotherapy;Estudo da evolucao do algoritmo de transporte de eletrons do GEANT4 para aplicacoes em radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Malthez, Anna Luiza M.C.; Button, Vera L. da S.N. [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Faculdade de Engenharia Eletrica e de Computacao. Dept. de Engenharia Biomedica; Rocha, Jose R. de O. [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Centro de Engenharia Biomedica

    2009-07-01

    In this work a bibliographic review was made about the GEANT4 applicability in radiotherapy, and also a study of electrons transport algorithm in order to establish the key points for future works with GEANT4. In papers already published, the GEANT4 version 4.6.1 was considered appropriated for photons simulations in applications of clinic significance in radiotherapy (accuracy {approx} 2%), however to electrons was checked that versions older than 8.3 present problems related to electrons transport algorithm, as size step artifact. The GEANT4 algorithm revision, version 8.3, resulted in substantial improvements of some values calculated in simulations, especially the loss energy per step and the boundary vicinity simulation of electrons, beyond better results stability, compared to versions 8.2. We concluded that electrons transport parameters within the following ranges: dRoverRange<0.3, RangeFactor=0.02, GeomFactor=3 and skin=1 is possible to get results with 1% accuracy to cavities simulations, although occur differences between simulated and theoretical doses, indicating that others parameters and the dose shift should be better evaluated. (author)

  15. A Geant4 simulation of the depth dose percentage in brain tumors treatments using protons and carbon ions

    Science.gov (United States)

    José A. Diaz, M.; Torres, D. A.

    2016-07-01

    The deposited energy and dose distribution of beams of protons and carbon over a head are simulated using the free tool package Geant4 and the data analysis package ROOT-C++. The present work shows a methodology to understand the microscopical process occurring in a session of hadron-therapy using advance simulation tools.

  16. Geant4 simulations of proton beam transport through a carbon or beryllium degrader and following a beam line

    NARCIS (Netherlands)

    van Goethem, M. J.; van der Meer, R.; Reist, H. W.; Schippers, J. M.

    2009-01-01

    Monte Carlo simulations based on the Geant4 simulation toolkit were performed for the carbon wedge degrader used in the beam line at the Center of Proton Therapy of the Paul Scherrer Institute (PSI). The simulations are part of the beam line studies for the development and understanding of the GANTR

  17. Influence of thyroid volume reduction on absorbed dose in 131I therapy studied by using Geant4 Monte Carlo simulation

    Science.gov (United States)

    Ziaur, Rahman; Sikander, M. Mirza; Waheed, Arshed; Nasir, M. Mirza; Waheed, Ahmed

    2014-05-01

    A simulation study has been performed to quantify the effect of volume reduction on the thyroid absorbed dose per decay and to investigate the variation of energy deposition per decay due to β- and γ-activity of 131I with volume/mass of thyroid, for water, ICRP- and ICRU-soft tissue taken as thyroid material. A Monte Carlo model of the thyroid, in the Geant4 radiation transport simulation toolkit was constructed to compute the β- and γ-absorbed dose in the simulated thyroid phantom for various values of its volume. The effect of the size and shape of the thyroid on energy deposition per decay has also been studied by using spherical, ellipsoidal and cylindrical models for the thyroid and varying its volume in 1-25 cm3 range. The relative differences of Geant4 results for different models with each other and MCNP results lie well below 1.870%. The maximum relative difference among the Geant4 estimated results for water with ICRP and ICRU soft tissues is not more than 0.225%. S-values for ellipsoidal, spherical and cylindrical thyroid models were estimated and the relative difference with published results lies within 3.095%. The absorbed fraction values for beta particles show a good agreement with published values within 2.105% deviation. The Geant4 based simulation results of absorbed fractions for gammas again show a good agreement with the corresponding MCNP and EGS4 results (±6.667%) but have 29.032% higher values than that of MIRD calculated values. Consistent with previous studies, the reduction of the thyroid volume is found to have a substantial effect on the absorbed dose. Geant4 simulations confirm dose dependence on the volume/mass of thyroid in agreement with MCNP and EGS4 computed values but are substantially different from MIRD8 data. Therefore, inclusion of size/mass dependence is indicated for 131I radiotherapy of the thyroid.

  18. Comparative study of different scattering geometries for the proposed Indian X-ray polarization measurement experiment using Geant4

    Energy Technology Data Exchange (ETDEWEB)

    Vadawale, S.V., E-mail: santoshv@prl.res.i [Physical Research Laboratory, Navarangpura, Ahmedabad 380 009 (India); Paul, B. [Raman Research Institute, Sadashivnagar, Bangalore 560 080 (India); Pendharkar, J.; Naik, Sachindra [Physical Research Laboratory, Navarangpura, Ahmedabad 380 009 (India)

    2010-06-21

    Polarization is a very important property of radiation from astrophysical sources. It carries unique information regarding the emission mechanism, physical conditions as well as emission geometry at the origin. Polarization measurements in X-rays can provide unique opportunity to study the behavior of matter and radiation under extreme magnetic fields and extreme gravitational fields. Unfortunately, over past two decades, when X-ray astronomy witnessed multiple order of magnitude improvement in temporal, spatial and spectral sensitivities, there is no (or very little) progress in the field of polarization measurements of astrophysical X-rays. Recently, a proposal has been submitted to Indian Space Research Organization (ISRO) for a dedicated small satellite based experiment to carry out X-ray polarization measurement, which aims to provide the first X-ray polarization measurements since 1976. This experiment will be based on the well known principle of polarization measurement by Thomson scattering and employs the baseline design of a central low Z scatterer (typically Lithium, Lithium Hydride or Beryllium) surrounded by X-ray detectors to measure the angular intensity distribution of the scattered X-rays. The sensitivity of such experiment is determined by the collecting area, scattering and detection efficiency, X-ray detector background, and the modulation factor. Therefore, it is necessary to carefully select the scattering geometry which can provide the highest modulation factor and thus highest sensitivity within the specified experimental constraints. The effective way to determine optimum scattering geometry is by studying various possible scattering geometries by means of Monte Carlo simulations. Here we present results of our detailed comparative study based on Geant4 simulations of five different scattering geometries which can be considered within the weight and size constraints of the proposed small satellite based X-ray polarization measurement

  19. Monte Carlo simulation of ruthenium eye plaques with GEANT4: influence of multiple scattering algorithms, the spectrum and the geometry on depth dose profiles

    Science.gov (United States)

    Sommer, H.; Ebenau, M.; Spaan, B.; Eichmann, M.

    2017-03-01

    Previous studies show remarkable differences in the simulation of electron depth dose profiles of ruthenium eye plaques. We examined the influence of the scoring and simulation geometry, the source spectrum and the multiple scattering algorithm on the depth dose profile using GEANT4. The simulated absolute dose deposition agrees with absolute dose data from the manufacturer within the measurement uncertainty. Variations in the simulation geometry as well as the source spectrum have only a small influence on the depth dose profiles. However, the multiple scattering algorithms have the largest influence on the depth dose profiles. They deposit up to 20% less dose compared to the single scattering implementation. We recommend researchers who are interested in simulating low- to medium-energy electrons to examine their simulation under the influence of different multiple scattering settings. Since the simulation and scoring geometry as well as the exact physics settings are best described by the source code of the application, we made the code publicly available.

  20. GEANT4 Simulations of Gamma-Gamma Angular Correlations with GRIFFIN

    Science.gov (United States)

    Natzke, Connor; Griffin Collaboration

    2016-09-01

    The structure of very neutron rich isotopes has been of recent experimental interest for both nuclear astrophysics and fundamental nuclear structure investigations. In beta-minus decay specifically, beta-delayed gamma cascades can help to shed light on the spin and parity of the states involved. One of the world's most powerful decay spectroscopy tool is the Gamma-Ray Infrastructure For Fundamental Investigations of Nuclei (GRIFFIN) spectrometer at TRIUMF-ISAC in Vancouver, Canada. To investigate the feasibility of these experimental studies, GEANT4 simulations of neutron-rich nuclei are critical, as they are able to provide realistic estimates of what the experimental results may look like. The first such nucleus investigated was 44P, and both the temporal and angular γγ correlations were extracted. Furthermore the simulations were used to model various multipole decay possibilities which provide a powerful tool analyzing collected data from such facilities. In the future, the Facility for Rare Isotope Beams (FRIB) at MSU will be an ideal site for such studies on the most exotic nuclei.

  1. Geant4 simulation study of Indian National Gamma Array at TIFR

    Science.gov (United States)

    Saha, S.; Palit, R.; Sethi, J.; Biswas, S.; Singh, P.

    2016-03-01

    A Geant4 simulation code for the Indian National Gamma Array (INGA) consisting of 24 Compton suppressed clover high purity germanium (HPGe) detectors has been developed. The calculated properties in the energy range that is of interest for nuclear γ-ray spectroscopy are spectral distributions for various standard radioactive sources, intrinsic peak efficiencies and peak-to-total (P/T) ratios in various configurations such as singles, add-back and Compton suppressed mode. The principle of operation of the detectors in add-back and Compton suppression mode have been reproduced in the simulation. The reliability of the calculation is checked by comparison with the experimental data for various γ-ray energies up to 5 MeV. The comparison between simulation results and experimental data demonstrate the need of incorporating the exact geometry of the clover detectors, Anti-Compton Shield and other surrounding materials in the array to explain the detector response to the γ-ray. Several experimental effects are also investigated. These include the geometrical correction to angular distribution, crosstalk probability and the impact of heavy metal collimators between the target and the array on the P/T ratio.

  2. Ion therapy for uveal melanoma in new human eye phantom based on GEANT4 toolkit

    Energy Technology Data Exchange (ETDEWEB)

    Mahdipour, Seyed Ali [Physics Department, Hakim Sabzevari University, Sabzevar (Iran, Islamic Republic of); Mowlavi, Ali Asghar, E-mail: amowlavi@hsu.ac.ir [Physics Department, Hakim Sabzevari University, Sabzevar (Iran, Islamic Republic of); ICTP, Associate Federation Scheme, Medical Physics Field, Trieste (Italy)

    2016-07-01

    Radiotherapy with ion beams like proton and carbon has been used for treatment of eye uveal melanoma for many years. In this research, we have developed a new phantom of human eye for Monte Carlo simulation of tumors treatment to use in GEANT4 toolkit. Total depth−dose profiles for the proton, alpha, and carbon incident beams with the same ranges have been calculated in the phantom. Moreover, the deposited energy of the secondary particles for each of the primary beams is calculated. The dose curves are compared for 47.8 MeV proton, 190.1 MeV alpha, and 1060 MeV carbon ions that have the same range in the target region reaching to the center of tumor. The passively scattered spread-out Bragg peak (SOBP) for each incident beam as well as the flux curves of the secondary particles including neutron, gamma, and positron has been calculated and compared for the primary beams. The high sharpness of carbon beam's Bragg peak with low lateral broadening is the benefit of this beam in hadrontherapy but it has disadvantages of dose leakage in the tail after its Bragg peak and high intensity of neutron production. However, proton beam, which has a good conformation with tumor shape owing to the beam broadening caused by scattering, can be a good choice for the large-size tumors.

  3. Simulating Neutron Interactions in the MoNA-LISA/Sweeper Setup with Geant4

    Science.gov (United States)

    McArthur, Magdalene

    2012-10-01

    The sweeper magnet is a superconducting dipole designed to bend charged particles of 4 Tm rigidity 43 degrees at a radius of approximately one meter. In a typical experiment neutron-unbound states are populated in a reaction in front of the magnet and emitted neutrons are subsequently detected with the high-efficiency position sensitive neutron detector arrays, MoNA and LISA. Before the neutrons interact in MoNA or LISA, they have to pass through the walls of the sweeper magnet chamber. A Monte Carlo simulation was written using Geant 4 which included MoNA and LISA, as well as the geometry of the sweeper magnet and the chamber. In a recent experiment LISA was positioned at large angles were the neutrons passed through the sidewalls of the chamber. The impact of the sidewalls on the neutron spectra was explored for neutrons from the decay of 12Li -> 11Li + n produced from 50 MeV/u 14B beams on a beryllium target.

  4. Benchmarking GEANT4 nuclear models for carbon-therapy at 95 MeV/A

    CERN Document Server

    Dudouet, J; Durand, D; Labalme, M

    2013-01-01

    In carbon-therapy, the interaction of the incoming beam with human tissues may lead to the production of a large amount of nuclear fragments and secondary light particles. An accurate estimation of the biological dose deposited into the tumor and the surrounding healthy tissues thus requires sophisticated simulation tools based on nuclear reaction models. The validity of such models requires intensive comparisons with as many sets of experimental data as possible. Up to now, a rather limited set of double di erential carbon fragmentation cross sections have been measured in the energy range used in hadrontherapy (up to 400 MeV/A). However, new data have been recently obtained at intermediate energy (95 MeV/A). The aim of this work is to compare the reaction models embedded in the GEANT4 Monte Carlo toolkit with these new data. The strengths and weaknesses of each tested model, i.e. G4BinaryLightIonReaction, G4QMDReaction and INCL++, coupled to two di fferent de-excitation models, i.e. the generalized evaporat...

  5. Geant4 simulation of the CERN-EU high-energy reference field (CERF) facility.

    Science.gov (United States)

    Prokopovich, D A; Reinhard, M I; Cornelius, I M; Rosenfeld, A B

    2010-09-01

    The CERN-EU high-energy reference field facility is used for testing and calibrating both active and passive radiation dosemeters for radiation protection applications in space and aviation. Through a combination of a primary particle beam, target and a suitable designed shielding configuration, the facility is able to reproduce the neutron component of the high altitude radiation field relevant to the jet aviation industry. Simulations of the facility using the GEANT4 (GEometry ANd Tracking) toolkit provide an improved understanding of the neutron particle fluence as well as the particle fluence of other radiation components present. The secondary particle fluence as a function of the primary particle fluence incident on the target and the associated dose equivalent rates were determined at the 20 designated irradiation positions available at the facility. Comparisons of the simulated results with previously published simulations obtained using the FLUKA Monte Carlo code, as well as with experimental results of the neutron fluence obtained with a Bonner sphere spectrometer, are made.

  6. Tuning of the GEANT4 FRITIOF (FTF) Model Using NA61/SHINE Experimental Data

    CERN Document Server

    Uzhinsky, V

    2011-01-01

    The NA61/SHINE collaboration measured inclusive cross sections of \\pi^+ and \\pi^- meson production in the interactions of 31 GeV/c protons with carbon nuclei at forward emission angles (0 - 420 mrad). The collaboration also presented predictions of Monte Carlo models - FLUKA, VENUS and UrQMD, in comparison with the data. A careful analysis shows that deviations of the FLUKA and VENUS predictions from the data have different tendencies. The worst description of the data was observed for the UrQMD model results. All the models assume the creation of quark-gluon strings in the interactions, but it is complicated to analyze the models in order to find the source of the deviations. Thus, the quark-gluon string model - FRITIOF (FTF) - was implemented in the GEANT4 toolkit and is used to understand the deviations mentioned above. It was found that the most important factor influencing the FTF calculations is the sampling of quark-gluon string masses. The other factors/parameters are not essential for a description o...

  7. Monte Carlo study of a 3D Compton imaging device with GEANT4

    CERN Document Server

    Lenti, M; 10.1016/j.nima.2011.06.060

    2011-01-01

    In this paper we investigate, with a detailed Monte-Carlo simulation based on Geant4, the novel approach [Nucl. Instrum. Methods A588 (2008) 457] to 3D imaging with photon scattering. A monochromatic and well collimated gamma beam is used to illuminate the object to be imaged and the photons Compton scattered are detected by means of a surrounding germanium strip detector. The impact position and the energy of the photons are measured with high precision and the scattering position along the beam axis is calculated. We study as an application of this technique the case of brain imaging but the results can be applied as well to situations where a lighter object, with localized variations of density, is embedded in a denser container. We report here the attainable sensitivity in the detection of density variations as a function of the beam energy, the depth inside the object and size and density of the inclusions. Using a 600 keV gamma beam, for an inclusion with a density increase of 30% with respect to the so...

  8. VIDA: a voxel-based dosimetry method for targeted radionuclide therapy using Geant4.

    Science.gov (United States)

    Kost, Susan D; Dewaraja, Yuni K; Abramson, Richard G; Stabin, Michael G

    2015-02-01

    We have developed the Voxel-Based Internal Dosimetry Application (VIDA) to provide patient-specific dosimetry in targeted radionuclide therapy performing Monte Carlo simulations of radiation transport with the Geant4 toolkit. The code generates voxel-level dose rate maps using anatomical and physiological data taken from individual patients. Voxel level dose rate curves are then fit and integrated to yield a spatial map of radiation absorbed dose. In this article, we present validation studies using established dosimetry results, including self-dose factors (DFs) from the OLINDA/EXM program for uniform activity in unit density spheres and organ self- and cross-organ DFs in the Radiation Dose Assessment Resource (RADAR) reference adult phantom. The comparison with reference data demonstrated agreement within 5% for self-DFs to spheres and reference phantom source organs for four common radionuclides used in targeted therapy ((131)I, (90)Y, (111)In, (177)Lu). Agreement within 9% was achieved for cross-organ DFs. We also present dose estimates to normal tissues and tumors from studies of two non-Hodgkin Lymphoma patients treated by (131)I radioimmunotherapy, with comparison to results generated independently with another dosimetry code. A relative difference of 12% or less was found between methods for mean absorbed tumor doses accounting for tumor regression.

  9. GEANT4 simulation of water volume fraction measurement in dehydrated crude oil

    Institute of Scientific and Technical Information of China (English)

    JING Chunguo; XING Guangzhong; LIU Bin

    2007-01-01

    Online measurement of water volume fraction (WVF) in dehydrated crude oil is a difficult task due to very little water in dehydrated crude oil and high precision requirements. We presents a method to measure water volume fraction in dehydrated crude oil with γ-ray densitometry. The Monte Carlo computer simulation packet GEANT4 was used to analyze the WVF measuring sensitivity of the γ-ray densitometry at different γ-ray energies, and effects of temperature, pressure, salinity and oil components on WVF measurement. The results show that the γ-ray densitome-try has high sensitivity in γ-ray energy ranges of 16~25 keV, and it can distinguish WVF changes of 0.0005. The calculated WVF decreases about 0.0002 with 1 ℃ of temperature increase and they have approximately linear relation with temperature when water volume fraction remains the same. Effects of pressure, salinity and oil components on water volume fraction can be neglected. Experiments were done to analyze sensitivity of the γ-ray densitometry. The results, as compared with simulations, demonstrate that simulation method is reliable and it is feasible to gauge low water volume fraction using low energy γ-rays.

  10. Simulation of ultrasoft X-rays induced DNA damage using the Geant4 Monte Carlo toolkit

    Science.gov (United States)

    Tajik, Marjan; Rozatian, Amir S. H.; Semsarha, Farid

    2015-01-01

    In this study, the total yields of SSB and DSB induced by monoenergetic electrons with energies of 0.28-4.55 keV, corresponding to ultrasoft X-rays energies, have been calculated in Charlton and Humm volume model using the Geant4-DNA toolkit and compared with theoretical and experimental data. A reasonable agreement between the obtained results in the present study and experimental and theoretical data of previous studies showed the efficiency of this model in estimating the total yield of strand breaks in spite of its simplicity. Also, it has been found that in the low energy region, the yield of the total SSB remains nearly constant while the DSB yield increases with decreasing energy. Moreover, a direct dependency between DSB induction, RBE value and the mean lineal energy as a microdosimetry quantity has been observed. In addition, it has become clear that the use of the threshold energy of 10.79 eV to calculate the total strand breaks yields results in a better agreement with the experiments, while the threshold of 17.5 eV shows a big difference.

  11. Optimization of a general-purpose, actively scanned proton beamline for ocular treatments: Geant4 simulations.

    Science.gov (United States)

    Piersimoni, Pierluigi; Rimoldi, Adele; Riccardi, Cristina; Pirola, Michele; Molinelli, Silvia; Ciocca, Mario

    2015-03-08

    The Italian National Center for Hadrontherapy (CNAO, Centro Nazionale di Adroterapia Oncologica), a synchrotron-based hospital facility, started the treatment of patients within selected clinical trials in late 2011 and 2012 with actively scanned proton and carbon ion beams, respectively. The activation of a new clinical protocol for the irradiation of uveal melanoma using the existing general-purpose proton beamline is foreseen for late 2014. Beam characteristics and patient treatment setup need to be tuned to meet the specific requirements for such a type of treatment technique. The aim of this study is to optimize the CNAO transport beamline by adding passive components and minimizing air gap to achieve the optimal conditions for ocular tumor irradiation. The CNAO setup with the active and passive components along the transport beamline, as well as a human eye-modeled detector also including a realistic target volume, were simulated using the Monte Carlo Geant4 toolkit. The strong reduction of the air gap between the nozzle and patient skin, as well as the insertion of a range shifter plus a patient-specific brass collimator at a short distance from the eye, were found to be effective tools to be implemented. In perspective, this simulation toolkit could also be used as a benchmark for future developments and testing purposes on commercial treatment planning systems.

  12. Ion therapy for uveal melanoma in new human eye phantom based on GEANT4 toolkit.

    Science.gov (United States)

    Mahdipour, Seyed Ali; Mowlavi, Ali Asghar

    2016-01-01

    Radiotherapy with ion beams like proton and carbon has been used for treatment of eye uveal melanoma for many years. In this research, we have developed a new phantom of human eye for Monte Carlo simulation of tumors treatment to use in GEANT4 toolkit. Total depth-dose profiles for the proton, alpha, and carbon incident beams with the same ranges have been calculated in the phantom. Moreover, the deposited energy of the secondary particles for each of the primary beams is calculated. The dose curves are compared for 47.8MeV proton, 190.1MeV alpha, and 1060MeV carbon ions that have the same range in the target region reaching to the center of tumor. The passively scattered spread-out Bragg peak (SOBP) for each incident beam as well as the flux curves of the secondary particles including neutron, gamma, and positron has been calculated and compared for the primary beams. The high sharpness of carbon beam׳s Bragg peak with low lateral broadening is the benefit of this beam in hadrontherapy but it has disadvantages of dose leakage in the tail after its Bragg peak and high intensity of neutron production. However, proton beam, which has a good conformation with tumor shape owing to the beam broadening caused by scattering, can be a good choice for the large-size tumors.

  13. Modeling of x-ray fluorescence using MCNPX and Geant4

    Energy Technology Data Exchange (ETDEWEB)

    Rajasingam, Akshayan [Los Alamos National Laboratory; Hoover, Andrew S [Los Alamos National Laboratory; Fensin, Michael L [Los Alamos National Laboratory; Tobin, Stephen J [Los Alamos National Laboratory

    2009-01-01

    X-Ray Fluorescence (XRF) is one of thirteen non-destructive assay techniques being researched for the purpose of quantifying the Pu mass in used fuel assemblies. The modeling portion of this research will be conducted with the MCNPX transport code. The research presented here was undertaken to test the capability of MCNPX so that it can be used to benchmark measurements made at the ORNL and to give confidence in the application of MCNPX as a predictive tool of the expected capability of XRF in the context of used fuel assemblies. The main focus of this paper is a code-to-code comparison between MCNPX and Geant4 code. Since XRF in used fuel is driven by photon emission and beta decay of fission fragments, both terms were independently researched. Simple cases and used fuel cases were modeled for both source terms. In order to prepare for benchmarking to experiments, it was necessary to determine the relative significance of the various fission fragments for producing X-rays.

  14. Simulation of ultrasoft X-rays induced DNA damage using the Geant4 Monte Carlo toolkit

    Energy Technology Data Exchange (ETDEWEB)

    Tajik, Marjan; Rozatian, Amir S.H. [Department of Physics, University of Isfahan, Hezar Jarib Street, Isfahan 81746-73441 (Iran, Islamic Republic of); Semsarha, Farid, E-mail: Semsarha@ibb.ut.ac.ir [Institute of Biochemistry and Biophysics (IBB), University of Tehran, P.O. Box: 13145-1384, Tehran (Iran, Islamic Republic of)

    2015-01-01

    In this study, the total yields of SSB and DSB induced by monoenergetic electrons with energies of 0.28–4.55 keV, corresponding to ultrasoft X-rays energies, have been calculated in Charlton and Humm volume model using the Geant4-DNA toolkit and compared with theoretical and experimental data. A reasonable agreement between the obtained results in the present study and experimental and theoretical data of previous studies showed the efficiency of this model in estimating the total yield of strand breaks in spite of its simplicity. Also, it has been found that in the low energy region, the yield of the total SSB remains nearly constant while the DSB yield increases with decreasing energy. Moreover, a direct dependency between DSB induction, RBE value and the mean lineal energy as a microdosimetry quantity has been observed. In addition, it has become clear that the use of the threshold energy of 10.79 eV to calculate the total strand breaks yields results in a better agreement with the experiments, while the threshold of 17.5 eV shows a big difference.

  15. Benchmarking geant4 nuclear models for hadron therapy with 95 MeV/nucleon carbon ions

    Science.gov (United States)

    Dudouet, J.; Cussol, D.; Durand, D.; Labalme, M.

    2014-05-01

    In carbon therapy, the interaction of the incoming beam with human tissue may lead to the production of a large amount of nuclear fragments and secondary light particles. An accurate estimation of the biological dose on the tumor and the surrounding healthy tissue thus requires sophisticated simulation tools based on nuclear reaction models. The validity of such models requires intensive comparisons with as many sets of experimental data as possible. Up to now, a rather limited set of double differential carbon fragmentation cross sections has been measured in the energy range used in hadron therapy (up to 400 MeV/nucleon). However, new data have been recently obtained at intermediate energy (95 MeV/nucleon). The aim of this work is to compare the reaction models embedded in the geant4 Monte Carlo toolkit with these new data. The strengths and weaknesses of each tested model, i.e., G4BinaryLightIonReaction, G4QMDReaction, and INCL++, coupled to two different de-excitation models, i.e., the generalized evaporation model and the Fermi break-up model, are discussed.

  16. Geant4 simulation of gamma conversion to muon pair for dark matter searches

    CERN Document Server

    Sokolov, Anton

    2017-01-01

    There is a direct evidence from different astronomical observations and CMB spectrum that 26% of the visible part of the Universe consists of so-called dark matter. There are many models explaining the phenomenon of dark matter, however none of them has been confirmed experimentally. It justifies the further searches for the dark matter that involve more and more various experiments, such as, for instance, SHiP experiment [1] at CERN or LDMX project [2] at SLAC. LDMX (Light Dark Matter eXperiment) is an electron fixedtarget missing momentum search for light dark matter. The main process that LDMX looks for is dark bremsstrahlung (i.e. emitting a light dark matter particle) by the several GeV electrons scattered off the target. This process is contaminated by the background of ordinary bremsstrahlung, that consists of many different processes which can be accounted for and vetoed by various counters. The experiment designs are studied with the Geant4 toolkit. Recently, one of the important background pro...

  17. Validation of the coupling of mesh models to GEANT4 Monte Carlo code for simulation of internal sources of photons; Validacao do acoplamento de modelos mesh ao codigo Monte Carlo GEANT4 para simulacao de fontes de fotons internas

    Energy Technology Data Exchange (ETDEWEB)

    Caribe, Paulo Rauli Rafeson Vasconcelos, E-mail: raulycaribe@hotmail.com [Universidade Federal Rural de Pernambuco (UFRPE), Recife, PE (Brazil). Fac. de Fisica; Cassola, Vagner Ferreira; Kramer, Richard; Khoury, Helen Jamil [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Departamento de Energia Nuclear

    2013-07-01

    The use of three-dimensional models described by polygonal meshes in numerical dosimetry enables more accurate modeling of complex objects than the use of simple solid. The objectives of this work were validate the coupling of mesh models to the Monte Carlo code GEANT4 and evaluate the influence of the number of vertices in the simulations to obtain absorbed fractions of energy (AFEs). Validation of the coupling was performed to internal sources of photons with energies between 10 keV and 1 MeV for spherical geometries described by the GEANT4 and three-dimensional models with different number of vertices and triangular or quadrilateral faces modeled using Blender program. As a result it was found that there were no significant differences between AFEs for objects described by mesh models and objects described using solid volumes of GEANT4. Since that maintained the shape and the volume the decrease in the number of vertices to describe an object does not influence so meant dosimetric data, but significantly decreases the time required to achieve the dosimetric calculations, especially for energies less than 100 keV.

  18. Validation of GEANT4 simulations for {sup 62,63}Zn yield estimation in proton induced reactions of natural copper

    Energy Technology Data Exchange (ETDEWEB)

    Rostampour, Malihe [Department of Physics, Arak University, P.O. Box: 38156, Arak (Iran, Islamic Republic of); Sadeghi, Mahdi, E-mail: msadeghi@nrcam.org [Medical Physics Department, School of Medicine, Iran University of Medical Sciences, P.O. Box: 14155-6183, Tehran (Iran, Islamic Republic of); Aboudzadeh, Mohammadreza [Radiation Application Research School, Nuclear Science and Technology Research Institute, P.O. Box: 11365-8486, Tehran (Iran, Islamic Republic of); Hamidi, Saeid [Department of Physics, Arak University, P.O. Box: 38156, Arak (Iran, Islamic Republic of); Hosseini, Seyedeh Fatemeh [Department of Physics, Payame Noor University, P.O. Box: 19395-3697, Tehran (Iran, Islamic Republic of)

    2017-03-01

    A useful approach to optimize of radioisotope production is the use of Monte Carlo simulations prior to experimentation. In this paper, the GEANT4 code was employed to calculate the saturation yields of {sup 62,63}Zn from proton-induced reactions of natural copper, enriched {sup 63}Cu and {sup 65}Cu. In addition, the saturation yields of the investigated radio-nuclides were calculated using the stopping power from the SRIM-2013 and reported experimental data for cross sections. The simulated saturation yields were compared with experimental values. Good agreement between the experimental and corresponding simulated data demonstrated that GEANT4 provides a suitable tool for radionuclide simulation production using proton irradiation.

  19. A probability-conserving cross-section biasing mechanism for Monte-Carlo variance reduction with application to Geant4

    CERN Document Server

    Mendenhall, Marcus H

    2011-01-01

    In Monte-Carlo codes such as Geant4, it is often important to adjust reaction cross sections to reduce the variance of calculations of relatively rare events, in a technique known as non-analogous Monte-Carlo. We present the theory and sample code for a Geant4 process which allows the cross section of a G4VDiscreteProcess to be scaled, while adjusting track weights so as to mitigate the effects of altered primary beam depletion induced by the cross section change. This allows us to increase the cross section of nuclear reactions by factors exceeding 10^{4} (in appropriate cases), without distorting the results of energy deposition calculations or coincidence rates. The procedure is also valid for bias factors less than unity, which is useful, for example, in problems which involve computation of particle penetration deep into a target, such as occurs in atmospheric showers or in shielding.

  20. Geant4 simulations of the Gamma Reaction History Diagnostic at the NIF, Omega and HIGS calibration facility

    Science.gov (United States)

    Rubery, Michael; Horsfield, Colin; Herrmann, Hans; Kim, Yong Ho; Mack, Joseph; Young, Carlton; Caldwell, Steven; Evans, Scott; Sedillo, Tom; McEvoy, Aaron; Miller, Kirk; Stoeffl, Wolfgang; Ali, Zaheer; Grafil, Elliott

    2010-11-01

    This paper discusses the development of a Geant4 model of the Gamma Reaction History (GRH) diagnostic at NIF and Omega, Inertial Confinement Fusion (ICF) laser facilities. The GRH diagnostic has been developed to measure bang-time and burn-width parameters for ICF implosions at both facilities, further investigations have also shown that measurements, such as ablator aerial density and ion temperature, may also be possible. Absolute gamma calibration experiments have been performed at the High Intensity Gamma Source (HIGS) facility at Duke University to increase confidence in parameters supplied by simulation for the use in calculations at both laser facilities. A comparison between HIGS data, Geant4 and the ITS ACCEPT code will be presented along with other important GRH properties, such as temporal unit response function, peak-timing shift and Cherenkov production profile, all as a function of pressure and incident gamma energy.

  1. Evaluation of open MPI and MPICH2 performances for the computation time in proton therapy dose calculations with Geant4

    Science.gov (United States)

    Kazemi, M.; Afarideh, H.; Riazi, Z.

    2015-11-01

    The aim of this research work is to use a better parallel software structure to improve the performance of the Monte Carlo Geant4 code in proton treatment planning. The hadron therapy simulation is rewritten to parallelize the shared memory multiprocessor systems by using the Message-Passing Interface (MPI). The speedup performance of the code has been studied by using two MPI-compliant libraries including Open MPI and the MPICH2, separately. Despite the speedup, the results are almost linear for both the Open MPI and MPICH2; the latter was chosen because of its better characteristics and lower computation time. The Geant4 parameters, including the step limiter and the set cut, have been analyzed to minimize the simulation time as much as possible. For a reasonable compromise between the spatial dose distribution and the calculation time, the improvement in time reduction coefficient reaches about 157.

  2. Progress and Validation of Geant4 Based Radioactive Decay Simulation Using the Examples of Simbol-X and IXO

    CERN Document Server

    Hauf, S; Pia, M G; Bell, Z; Briel, U; Chipaux, R; Hoffmann, D H H; Kendziorra, E; Laurent, P; Strüder, L; Tenzer, C; Weidenspointer, G; Zoglauer, A

    2009-01-01

    The anticipated high sensitivity and the science goals of the next generation X-ray space missions, like the International X-ray Observatory or Simbol-X, rely on a low instrumental background, which in turn requires optimized shielding concepts. We present Geant4 based simulation results on the IXO Wide Field Imager cosmic ray proton induced background in comparison with previous results obtained for the Simbol-X LED and HED focal plane detectors. Our results show that an improvement in mean differential background flux compared to actually operating X-ray observatories may be feasible with detectors based on DEPFET technology. In addition we present preliminary results concerning the validation of Geant4 based radioactive decay simulation in space applications as a part of the Nano5 project.

  3. Electromagnetism

    CERN Document Server

    Grant, Ian S

    1990-01-01

    The Manchester Physics Series General Editors: D. J. Sandiford; F. Mandl; A. C. Phillips Department of Physics and Astronomy, University of Manchester Properties of Matter B. H. Flowers and E. Mendoza Optics Second Edition F. G. Smith and J. H. Thomson Statistical Physics Second Edition F. Mandl Electromagnetism Second Edition I. S. Grant and W. R. Phillips Statistics R. J. Barlow Solid State Physics Second Edition J. R. Hook and H. E. Hall Quantum Mechanics F. Mandl Particle Physics Second Edition B. R. Martin and G. Shaw the Physics of Stars Second Edition A. C. Phillips Computing for Scient

  4. Optimization of {sup 6}LiF:ZnS(Ag) Scintillator Light Yield Using Geant4

    Energy Technology Data Exchange (ETDEWEB)

    Yehuda-Zada, Y. [Nuclear Research Center Negev, Beer-Sheva (Israel); Ben-Gurion University (Israel); Pritchard, K.; Ziegler, J.B.; Cooksey, C.; Siebein, K. [National Institute of Standards and Technology, Gaithersburg, Maryland (United States); Jackson, M.; Hurlbut, C. [Eljen Technology, Sweetwater Texas (United States); Kadmon, Y.; Cohen, Y.; Maliszewskyj, N.C. [Nuclear Research Center Negev, Beer-Sheva (Israel); Ibberson, R.M.; Majkrzak, C.F. [National Institute of Standards and Technology, Gaithersburg, Maryland (United States); Orion, Y. [Ben-Gurion University (Israel); Osovizky, A. [National Institute of Standards and Technology, Gaithersburg, Maryland (United States); Rotem Industries Ltd, Rotem Industrial Park (Israel); University of Maryland (United States)

    2015-07-01

    Neutrons provide an effective tool to probe materials structure. Neutron diffraction is a method to determine the atomic and magnetic structure of a material based on neutron scattering. By this method a collimated incident beam of thermal neutrons heat the examined sample and based on the obtained diffraction pattern information on the structure of the material is provided. Research for developing a novel cold neutron detector for Chromatic Analysis Neutron Diffractometer Or Reflectometer (CANDOR) is underway at the NIST center for neutron research. The system unique design is aimed to provide over ten times fold faster analysis of materials than conventional system. In order to achieve the fast analysis a large number of neutron detectors is required. A key design constraint for this detector is the thickness of the neutron sensitive element. This is met using {sup 6}LiF:ZnS(Ag) scintillation material with embedded wavelength shifting (WLS) fibers conducting scintillation light to silicon photomultiplier photo-sensors. The detector sensitivity is determined by both the neutron capture probability ({sup 6}Li density) and the detectable light output produced by the ZnS(Ag) ionization, the latter of which is hindered by the fluorescence absorption of the scintillation light by the ZnS. Tradeoffs between the neutron capture probability, stimulated light production and light attenuation for determining the optimal stoichiometry of the {sup 6}LiF and ZnS(Ag) as well as the volume ratio of scintillator and fiber. Simulations performed using the GEANT4 Monte Carlo package were made in order to optimize the detector design. GEANT4 enables the investigation of the neutron interaction with the detector, the ionization process and the light transfer process following the nuclear process. The series of conversions required for this detector were modelled: - A cold neutron enters the sensor and is captured by {sup 6}Li in the scintillator mixture ({sup 6}Li (n,α) {sup 3}H

  5. The GEANT4 toolkit capability in the hadron therapy field: simulation of a transport beam line

    Science.gov (United States)

    Cirrone, G. A. P.; Cuttone, G.; Di Rosa, F.; Raffaele, L.; Russo, G.; Guatelli, S.; Pia, M. G.

    2006-01-01

    At Laboratori Nazionali del Sud of the Instituto Nazionale di Fisica Nucleare of Catania (Sicily, Italy), the first Italian hadron therapy facility named CATANA (Centro di AdroTerapia ed Applicazioni Nucleari Avanzate) has been realized. Inside CATANA 62 MeV proton beams, accelerated by a superconducting cyclotron, are used for the radiotherapeutic treatments of some types of ocular tumours. Therapy with hadron beams still represents a pioneer technique, and only a few centers worldwide can provide this advanced specialized cancer treatment. On the basis of the experience so far gained, and considering the future hadron-therapy facilities to be developed (Rinecker, Munich Germany, Heidelberg/GSI, Darmstadt, Germany, PSI Villigen, Switzerland, CNAO, Pavia, Italy, Centro di Adroterapia, Catania, Italy) we decided to develop a Monte Carlo application based on the GEANT4 toolkit, for the design, the realization and the optimization of a proton-therapy beam line. Another feature of our project is to provide a general tool able to study the interactions of hadrons with the human tissue and to test the analytical-based treatment planning systems actually used in the routine practice. All the typical elements of a hadron-therapy line, such as diffusers, range shifters, collimators and detectors were modelled. In particular, we simulated the Markus type ionization chamber and a Gaf Chromic film as dosimeters to reconstruct the depth (Bragg peak and Spread Out Bragg Peak) and lateral dose distributions, respectively. We validated our simulated detectors comparing the results with the experimental data available in our facility.

  6. Geant4 Analysis of a Thermal Neutron Real-Time Imaging System

    Science.gov (United States)

    Datta, Arka; Hawari, Ayman I.

    2017-07-01

    Thermal neutron imaging is a technique for nondestructive testing providing complementary information to X-ray imaging for a wide range of applications in science and engineering. Advancement of electronic imaging systems makes it possible to obtain neutron radiographs in real time. This method requires a scintillator to convert neutrons to optical photons and a charge-coupled device (CCD) camera to detect those photons. Alongside, a well collimated beam which reduces geometrical blurriness, the use of a thin scintillator can improve the spatial resolution significantly. A representative scintillator that has been applied widely for thermal neutron imaging is 6LiF:ZnS (Ag). In this paper, a multiphysics simulation approach for designing thermal neutron imaging system is investigated. The Geant4 code is used to investigate the performance of a thermal neutron imaging system starting with a neutron source and including the production of charged particles and optical photons in the scintillator and their transport for image formation in the detector. The simulation geometry includes the neutron beam collimator and sapphire filter. The 6LiF:ZnS (Ag) scintillator is modeled along with a pixelated detector for image recording. The spatial resolution of the system was obtained as the thickness of the scintillator screen was varied between 50 and 400 μm. The results of the simulation were compared to experimental results, including measurements performed using the PULSTAR nuclear reactor imaging beam, showing good agreement. Using the established model, further examination showed that the resolution contribution of the scintillator screen is correlated with its thickness and the range of the neutron absorption reaction products (i.e., the alpha and triton particles). Consequently, thinner screens exhibit improved spatial resolution. However, this will compromise detection efficiency due to the reduced probability of neutron absorption.

  7. The simulation of the LANFOS-H food radiation contamination detector using Geant4 package

    Science.gov (United States)

    Piotrowski, Lech Wiktor; Casolino, Marco; Ebisuzaki, Toshikazu; Higashide, Kazuhiro

    2015-02-01

    Recent incident in the Fukushima power plant caused a growing concern about the radiation contamination and resulted in lowering the Japanese limits for the permitted amount of 137Cs in food to 100 Bq/kg. To increase safety and ease the concern we are developing LANFOS (Large Food Non-destructive Area Sampler)-a compact, easy to use detector for assessment of radiation in food. Described in this paper LANFOS-H has a 4 π coverage to assess the amount of 137Cs present, separating it from the possible 40K food contamination. Therefore, food samples do not have to be pre-processed prior to a test and can be consumed after measurements. It is designed for use by non-professionals in homes and small institutions such as schools, showing safety of the samples, but can be also utilized by specialists providing radiation spectrum. Proper assessment of radiation in food in the apparatus requires estimation of the γ conversion factor of the detectors-how many γ photons will produce a signal. In this paper we show results of the Monte Carlo estimation of this factor for various approximated shapes of fish, vegetables and amounts of rice, performed with Geant4 package. We find that the conversion factor combined from all the detectors is similar for all food types and is around 37%, varying maximally by 5% with sample length, much less than for individual detectors. The different inclinations and positions of samples in the detector introduce uncertainty of 1.4%. This small uncertainty validates the concept of a 4 π non-destructive apparatus.

  8. Geant4 simulations on medical Linac operation at 18 MV: Experimental validation based on activation foils

    Science.gov (United States)

    Vagena, E.; Stoulos, S.; Manolopoulou, M.

    2016-03-01

    The operation of a medical linear accelerator was simulated using the Geant4 code regarding to study the characteristics of an 18 MeV photon beam. Simulations showed that (a) the photon spectrum at the isocenter is not influenced by changes of the primary electron beam's energy distribution and spatial spread (b) 98% of the photon energy fluence scored at the isocenter is primary photons that have only interacted with the target (c) the number of contaminant electrons is not negligible since it fluctuated around 5×10-5 per primary electron or 2.40×10-3 per photon at the isocenter (d) the number of neutrons that are created by (γ, n) reactions is 3.13×10-6 per primary electron or 1.50×10-3 per photon at the isocenter (e) a flattening filter free beam needs less primary electrons in order to deliver the same photon fluence at the isocenter than a normal flattening filter operation (f) there is no significant increase of the surface dose due to the contaminant electrons by removing the flattening filter (g) comparing the neutron fluences per incident electron for the flattened and unflattened beam, the neutron fluencies is 7% higher for the unflattened beams. To validate the simulations results, the total neutron and photon fluence at the isocenter field were measured using nickel, indium, and natural uranium activation foils. The percentage difference between simulations and measurements was 1.26% in case of uranium and 2.45% in case of the indium foil regarding photon fluencies while for neutrons the discrepancy is higher up to 8.0%. The photon and neutron fluencies of the simulated experiments fall within a range of ±1 and ±2 sigma error, respectively, compared to the ones obtained experimentally.

  9. GEANT4 simulation of plastic scintillator strips with embedded optical fibers for a prototype of tomographic system

    Energy Technology Data Exchange (ETDEWEB)

    Riggi, S., E-mail: simone.riggi@ct.infn.i [Department of Physics and Astronomy, University of Catania (Italy); INFN Section of Catania (Italy); Centro Siciliano di Fisica Nucleare e Struttura della Materia (Italy); La Rocca, P. [Department of Physics and Astronomy, University of Catania (Italy); INFN Section of Catania (Italy); Museo Storico della Fisica e Centro Studi e Ricerche ' E. Fermi' , Roma (Italy); Leonora, E.; Lo Presti, D. [Department of Physics and Astronomy, University of Catania (Italy); INFN Section of Catania (Italy); Pappalardo, G.S. [INFN Section of Catania (Italy); Riggi, F.; Russo, G.V. [Department of Physics and Astronomy, University of Catania (Italy); INFN Section of Catania (Italy)

    2010-12-21

    The response to cosmic muons of plastic scintillator strips, with and without wavelength shifter fibers embedded, read out at both edges by photomultipliers has been studied through detailed GEANT4 simulations, with the aim of studying the light collection at the module ends under different conditions. The performed simulations, validated and tuned with data coming from a module prototype, could serve as an important guide for the design of a tomographic system based on cosmic ray muons.

  10. Influence of various geometries on detection efficiency of polystyrene, polyvinyl-toluene, and sodium iodide detectors using Geant4

    Directory of Open Access Journals (Sweden)

    Mirza Sikander M.

    2015-01-01

    Full Text Available In this work, comparative study on energy dependence of absorbed, intrinsic, photo-peak and absolute total efficiency of polystyrene plastic scintillation fiber and polyvinyl-toluene detectors with NaI(Tl scintillation detectors has been performed using Geant4 version 9.6 toolkit. The effects of geometry parameters on various efficiencies were investigated by varying detector radii, thickness and various source-to-detector configurations. These studies were carried out for both cylindrical and slab geometries for photon energy range of 10 keV-20 MeV using point isotropic sources and parallel beams of photons. Comparisons of the Geant4.9.6 based simulations for polystyrene scintillation fiber intrinsic efficiency as a function of photon energy and corresponding results obtained by earlier versions Geant4 (version 5.1 and Geant4 (version 8.1 show good agreements. The variation of the intrinsic efficiency with energy for polyvinyltoluene is also found to match very well with respective earlier results. This work confirms that the plastic scintillator based fibers and slab detectors are suitable for X-ray and low energy g-ray applications with energies typically below 50 keV with the optimum length of polystyrene scintillation fiber equal to 10 cm. For high energy range, cross talk remains an issue for polystyrene scintillation fiber and it is prominent in fibers having longer lengths and small diameters. Also, until the fiber radius is smaller than the incident photon beam, the fiber intrinsic efficiency increases with an increase in the radius.

  11. Implementation of the LPM effect in the discrete-bremsstrahlung simulation of GEANT 3 and GEANT 4

    Energy Technology Data Exchange (ETDEWEB)

    Mangiarotti, A. [Laboratorio de Instrumentacao e Fisica Experimental de Parti' culas, Coimbra (Portugal); Ballestrero, S. [School of Physics, University of the Witwatersrand, Johannesburg (South Africa); Sona, P. [Dipartimento di Fisica, Universita degli Studi di Firenze, Polo Scientifico, Sesto F.no, Via G. Sansone 1, Sesto Fiorentino 50019 , Firenze (Italy)], E-mail: pietro.sona@fi.infn.it; Uggerhoj, U.I. [Department of Physics and Astronomy, University of Aarhus, Aarhus (Denmark)

    2008-12-15

    Experimental data, recently measured at CERN, on the LPM effect have been used to benchmark the description of the discrete bremsstrahlung incorporated into the GEANT 3 and GEANT 4 codes. The limited accuracy of the native versions required a major revision in the framework of the original Migdal theory. The results obtained with the new implementation agree quite satisfactorily with measurements. The stability of the calculations when several parameters are varied has been thoroughly investigated.

  12. Geant4 Parametrization And Modeling Of Pion Production In Proton-nucleus Interactions Based On Harp Experimental Data: Incident Proton Momenta Are From 3 Gev/c To 12.9 Gev/c

    CERN Document Server

    Giani, S; Panman, J; Grichine, V

    2008-01-01

    Expeimental data of HARP (the hadron production experiment at CERN-PS, PS214) describing inclusive spectra of pions produced in proton-nucleus interactions in the momentum range 3-12.9 GeV/c were compared versus Geant4 model predictions. No special tuning of Geant4 models was done. In addition the data were parameterized in the form suitable for Geant4 and their parameterization is proposed to be used in Geant4 hadron generators.

  13. Validation of the Geant4 Monte Carlo package for X-ray fluorescence spectroscopy in triaxial geometry

    Science.gov (United States)

    Amaro, Pedro; Santos, José Paulo; Samouco, Ana; Adão, Ricardo; Martins, Luís Souto; Weber, Sebastian; Tashenov, Stanislav; Carvalho, Maria Luisa; Pessanha, Sofia

    2017-04-01

    In this study, we investigated the potential of the Geant4 Monte Carlo simulation package for retrieving accurate elemental concentrations from energy dispersive X-ray fluorescence spectra. For this purpose, we implemented a Geant4 code that simulates an energy dispersive X-ray fluorescence spectrometer in a triaxial geometry. In parallel, we also performed measurements in a spectrometer with the same geometry, for validation of the present code. This spectrometer allows low limits of detection and permits an effective comparison of elemental concentrations down to tens of part-per-million. Several standard reference materials of both light, medium and heavy matrices were employed in order to attest the validity of simulations for several values of averaged atomic number. We observed good agreement of better than 25% for most fluorescence lines of interest, and for all materials. Discrepancies were observed at the multiple Compton scattering tail. We thus concluded from this experimental and theoretical study that the present Geant4 code can be incorporated in a quantitative method for the determination of trace elements in a triaxial-type spectrometer.

  14. Development of a computational system based in the code GEANT4 for dosimetric evaluation in radiotherapy; Desenvolvimento de um sistema computacional baseado no Codigo GEANT4 para avaliacoes dosimetricas em radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Alex Cristovao Holanda de

    2016-10-01

    The incidence of cancer has grown in Brazil, as well as around the world, following the change in the age profile of the population. One of the most important techniques and commonly used in cancer treatment is radiotherapy. Around 60% of new cases of cancer use radiation in at least one phase of treatment. The most used equipment for radiotherapy is a linear accelerator (Linac) which produces electron or X-ray beams in energy range from 5 to 30 MeV. The most appropriate way to irradiate a patient is determined during treatment planning. Currently, treatment planning system (TPS) is the main and the most important tool in the process of planning for radiotherapy. The main objective of this work is to develop a computational system based on the MC code Geant4 for dose evaluations in photon beam radiotherapy. In addition to treatment planning, these dose evaluations can be performed for research and quality control of equipment and TPSs. The computer system, called Quimera, consists of a graphical user interface (qGUI) and three MC applications (qLinacs, qMATphantoms and qNCTphantoms). The qGUI has the function of interface for the MC applications, by creating or editing the input files, running simulations and analyzing the results. The qLinacs is used for modeling and generation of Linac beams (phase space). The qMATphantoms and qNCTphantoms are used for dose calculations in virtual models of physical phantoms and computed tomography (CT) images, respectively. From manufacturer's data, models of a Varian Linac photon beam and a Varian multileaf collimator (MLC) were simulated in the qLinacs. The Linac and MLC modelling were validated using experimental data. qMATphamtoms and qNCTphantoms were validated using IAEA phase spaces. In this first version, the Quimera can be used for research, radiotherapy planning of simple treatments and quality control in photon beam radiotherapy. The MC applications work independent of the qGUI and the qGUI can be used for

  15. PDB4DNA: Implementation of DNA geometry from the Protein Data Bank (PDB) description for Geant4-DNA Monte-Carlo simulations

    Science.gov (United States)

    Delage, E.; Pham, Q. T.; Karamitros, M.; Payno, H.; Stepan, V.; Incerti, S.; Maigne, L.; Perrot, Y.

    2015-07-01

    This paper describes PDB4DNA, a new Geant4 user application, based on an independent, cross-platform, free and open source C++ library, so-called PDBlib, which enables use of atomic level description of DNA molecule in Geant4 Monte Carlo particle transport simulations. For the evaluation of direct damage induced on the DNA molecule by ionizing particles, the application makes use of an algorithm able to determine the closest atom in the DNA molecule to energy depositions. Both the PDB4DNA application and the PDBlib library are available as free and open source under the Geant4 license.

  16. GEANT4 used for neutron beam design of a neutron imaging facility at TRIGA reactor in Morocco

    Science.gov (United States)

    Ouardi, A.; Machmach, A.; Alami, R.; Bensitel, A.; Hommada, A.

    2011-09-01

    Neutron imaging has a broad scope of applications and has played a pivotal role in visualizing and quantifying hydrogenous masses in metallic matrices. The field continues to expand into new applications with the installation of new neutron imaging facilities. In this scope, a neutron imaging facility for computed tomography and real-time neutron radiography is currently being developed around 2.0MW TRIGA MARK-II reactor at Maamora Nuclear Research Center in Morocco (Reuscher et al., 1990 [1]; de Menezes et al., 2003 [2]; Deinert et al., 2005 [3]). The neutron imaging facility consists of neutron collimator, real-time neutron imaging system and imaging process systems. In order to reduce the gamma-ray content in the neutron beam, the tangential channel was selected. For power of 250 kW, the corresponding thermal neutron flux measured at the inlet of the tangential channel is around 3×10 11 ncm 2/s. This facility will be based on a conical neutron collimator with two circular diaphragms with diameters of 4 and 2 cm corresponding to L/D-ratio of 165 and 325, respectively. These diaphragms' sizes allow reaching a compromise between good flux and efficient L/D-ratio. Convergent-divergent collimator geometry has been adopted. The beam line consists of a gamma filter, fast neutrons filter, neutron moderator, neutron and gamma shutters, biological shielding around the collimator and several stages of neutron collimator. Monte Carlo calculations by a fully 3D numerical code GEANT4 were used to design the neutron beam line ( http://www.info.cern.ch/asd/geant4/geant4.html[4]). To enhance the neutron thermal beam in terms of quality, several materials, mainly bismuth (Bi) and sapphire (Al 2O 3) were examined as gamma and neutron filters respectively. The GEANT4 simulations showed that the gamma and epithermal and fast neutron could be filtered using the bismuth (Bi) and sapphire (Al 2O 3) filters, respectively. To get a good cadmium ratio, GEANT 4 simulations were used to

  17. Compton polarimeter as a focal plane detector for hard X-ray telescope: sensitivity estimation with Geant4 simulations

    Science.gov (United States)

    Chattopadhyay, T.; Vadawale, S. V.; Pendharkar, J.

    2013-04-01

    X-ray polarimetry can be an important tool for investigating various physical processes as well as their geometries at the celestial X-ray sources. However, X-ray polarimetry has not progressed much compared to the spectroscopy, timing and imaging mainly due to the extremely photon-hungry nature of X-ray polarimetry leading to severely limited sensitivity of X-ray polarimeters. The great improvement in sensitivity in spectroscopy and imaging was possible due to focusing X-ray optics which is effective only at the soft X-ray energy range. Similar improvement in sensitivity of polarisation measurement at soft X-ray range is expected in near future with the advent of GEM based photoelectric polarimeters. However, at energies >10 keV, even spectroscopic and imaging sensitivities of X-ray detector are limited due to lack of focusing optics. Thus hard X-ray polarimetry so far has been largely unexplored area. On the other hand, typically the polarisation degree is expected to increase at higher energies as the radiation from non-thermal processes is dominant fraction. So polarisation measurement in hard X-ray can yield significant insights into such processes. With the recent availability of hard X-ray optics (e.g. with upcoming NuSTAR, Astro-H missions) which can focus X-rays from 5 KeV to 80 KeV, sensitivity of X-ray detectors in hard X-ray range is expected to improve significantly. In this context we explore feasibility of a focal plane hard X-ray polarimeter based on Compton scattering having a thin plastic scatterer surrounded by cylindrical array scintillator detectors. We have carried out detailed Geant4 simulation to estimate the modulation factor for 100 % polarized beam as well as polarimetric efficiency of this configuration. We have also validated these results with a semi-analytical approach. Here we present the initial results of polarisation sensitivities of such focal plane Compton polarimeter coupled with the reflection efficiency of present era hard X

  18. 基于Geant4模拟质子在半导体Si材料中的NIEL值%Simulation of proton NIEL in silicon by using GEANT4

    Institute of Scientific and Technical Information of China (English)

    路伟; 王同权; 王兴功; 刘雪林

    2011-01-01

    利用蒙特卡洛软件GEANT4模拟了质子对半导体Si材料的位移损伤效应的能量损失.根据反冲原子的能量,引入反冲原子能量Lindbard-Robinson-Akkerman分离函数,模拟结果表明10MeV-1 GeV能量范围内的质子位移能量损失值和Jun、Summers等结果吻合较好.

  19. Vector Potential, Electromagnetic Induction and "Physical Meaning"

    Science.gov (United States)

    Giuliani, G.

    2010-01-01

    A forgotten experiment by Andre Blondel (1914) proves, as held on the basis of theoretical arguments in a previous paper, that the time variation of the magnetic flux is not the cause of the induced emf; the physical agent is instead the vector potential through the term [equation omitted] (when the induced circuit is at rest). The "good…

  20. SU-E-T-427: Feasibility Study for Evaluation of IMRT Dose Distribution Using Geant4-Based Automated Algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Choi, H; Shin, W; Testa, M; Min, C [Yonsei University, Wonju (Korea, Republic of); Kim, J [Seoul National University Hospital, Seoul (Korea, Republic of)

    2015-06-15

    Purpose: For intensity-modulated radiation therapy (IMRT) treatment planning validation using Monte Carlo (MC) simulations, a precise and automated procedure is necessary to evaluate the patient dose distribution. The aim of this study is to develop an automated algorithm for IMRT simulations using DICOM files and to evaluate the patient dose based on 4D simulation using the Geant4 MC toolkit. Methods: The head of a clinical linac (Varian Clinac 2300 IX) was modeled in Geant4 along with particular components such as the flattening filter and the multi-leaf collimator (MLC). Patient information and the position of the MLC were imported from the DICOM-RT interface. For each position of the MLC, a step- and-shoot technique was adopted. PDDs and lateral profiles were simulated in a water phantom (50×50×40 cm{sup 3}) and compared to measurement data. We used a lung phantom and MC-dose calculations were compared to the clinical treatment planning used at the Seoul National University Hospital. Results: In order to reproduce the measurement data, we tuned three free parameters: mean and standard deviation of the primary electron beam energy and the beam spot size. These parameters for 6 MV were found to be 5.6 MeV, 0.2378 MeV and 1 mm FWHM respectively. The average dose difference between measurements and simulations was less than 2% for PDDs and radial profiles. The lung phantom study showed fairly good agreement between MC and planning dose despite some unavoidable statistical fluctuation. Conclusion: The current feasibility study using the lung phantom shows the potential for IMRT dose validation using 4D MC simulations using Geant4 tool kits. This research was supported by Korea Institute of Nuclear safety and Development of Measurement Standards for Medical Radiation funded by Korea research Institute of Standards and Science. (KRISS-2015-15011032)

  1. Desarrollos y aplicaciones de GEANT4 para radioterapia y microdosimetría en detectores y circuitos integrados

    OpenAIRE

    Cortes Giraldo, Miguel Antonio

    2011-01-01

    El objetivo general de este proyecto es abrir nuevas líneas de investigación en el Departamento de Física Atómica, Molecular y Nuclear de la Universidad de Sevilla, relacionadas con el estudio del transporte de radiación a través de la materia mediante ... simulaciones Monte Carlo. En esta memoria, se presentan las aplicaciones desarrolladas con el código GEANT4 en diversos campos de investigación.Este documento se divide en cuatro partes. En la primera, se realiza una breve introducción sobr...

  2. Creation of a Geant4 Muon Tomography Package for Imaging of Nuclear Fuel in Dry Cask Storage

    Energy Technology Data Exchange (ETDEWEB)

    Tsoukalas, Lefteri H. [Purdue Univ., West Lafayette, IN (United States)

    2016-03-01

    This is the final report of the NEUP project “Creation of a Geant4 Muon Tomography Package for Imaging of Nuclear Fuel in Dry Cask Storage”, DE-NE0000695. The project started on December 1, 2013 and this report covers the period December 1, 2013 through November 30, 2015. The project was successfully completed and this report provides an overview of the main achievements, results and findings throughout the duration of the project. Additional details can be found in the main body of this report and on the individual Quarterly Reports and associated Deliverables of the project, uploaded in PICS-NE.

  3. Investigation of behavior of scintillator detector of Alborz observatory array using Monte Carlo method with Geant4 code

    Directory of Open Access Journals (Sweden)

    M. Abbasian Motlagh

    2014-04-01

    Full Text Available For their appropriate temporal resolution, scintillator detectors are used in the Alborz observatory. In this work, the behavior of the scintillation detectors for the passage of electrons with different energies and directions were studied using the simulation code GEANT4. Pulse shapes of scintillation light, and such characteristics as the total number of photons, the rise time and the falling time for the optical pulses were computed for the passage of electrons with energies of 10, 100 and 1000 MeV. Variations of the characteristics of optical pulse of scintillation with incident angle and the location of electrons were also investigated

  4. Desarrollos y aplicaciones de GEANT4 para radioterapia y microdosimetría en detectores y circuitos integrados

    OpenAIRE

    Cortes Giraldo, Miguel Antonio

    2011-01-01

    El objetivo general de este proyecto es abrir nuevas líneas de investigación en el Departamento de Física Atómica, Molecular y Nuclear de la Universidad de Sevilla, relacionadas con el estudio del transporte de radiación a través de la materia mediante ... simulaciones Monte Carlo. En esta memoria, se presentan las aplicaciones desarrolladas con el código GEANT4 en diversos campos de investigación.Este documento se divide en cuatro partes. En la primera, se realiza una breve introducción sobr...

  5. Atomic, molecular, and optical physics electromagnetic radiation

    CERN Document Server

    Dunning, F B; Lucatorto, Thomas

    1997-01-01

    Combined with Volumes 29A and 29B, this volume is a comprehensive treatment of the key experimental methods of atomic, molecular, and optical physics, as well as an excellent experimental handbook for the field. Thewide availability of tunable lasers in the past several years has revolutionized the field and lead to the introduction of many new experimental methods that are covered in these volumes. Traditional methods are also included to ensure that the volumes will be a complete reference source for the field.

  6. The Energy Compensation Study of Geiger -Mueller Tube Based on Geant4%基于Geant4的盖革计数管能量补偿研究

    Institute of Scientific and Technical Information of China (English)

    龚玉巍; 刘明健; 张燕; 贾铭椿; 龚军军

    2011-01-01

    The energy response of Geiger - Mueller (GM) tube to ga mma radiation in wide energy range is mainly researched, and characteristics of energy response are briefly explained in theory. Some factors that influence energy response are analysed in the model of J4403 tube by Geant4. The analysis obtains energy response of compensated tube with various compensation shields, which provides the foundation for energy compensation.%重点研究了盖革计数管对于较宽能量范围的各能量γ射线的响应情况,从理论上简要说明了盖革计数管的能量响应特点,并针对国产的J4403型计数管使用蒙特卡罗软件Geant4分析了实际情况下能量补偿的各个影响因素,得到不同结构参数下计数管的能量响应情况,为计数管的能量补偿提供了依据.

  7. 4He和12C离子Rutherford背散射的Geant4模拟%Geant4-Based Simulation of 4 He and 12C Ions Rutherford Backscattering on Thin Films

    Institute of Scientific and Technical Information of China (English)

    王振超; 马玉刚; 杨海芳; 牛璐莹; 周庆; 赵广义; 宋明珠

    2013-01-01

    The Rutherford backscattering spectra (RBS) of 4 He and 12C normally incident on Au,Ag,Cu thin films at 270 keV and 500 keV were simulated via Geant4.Effects of different materials,thickness and energy of incident ions on RBS were discussed.The characters of 4He,12C RBS were analyzed.It was found that the mass resolution is much better for 12C RBS than that for 4He RBS.%利用Geant4程序模拟270,500 keV 4 He和12C离子垂直入射Au,Ag,Cu薄膜上的Rutherford背散射谱(RBS),并讨论材料、厚度和入射离子能量对背散射谱的影响.结果表明,能量较大的12C离子具有较好的质量分辨率.

  8. Fast Simulation of Electromagnetic Showers in the ATLAS Calorimeter: Frozen Showers

    Energy Technology Data Exchange (ETDEWEB)

    Barberio, E.; /Melbourne U.; Boudreau, J.; /Pittsburgh U.; Butler, B.; /SLAC; Cheung, S.L.; /Toronto U.; Dell' Acqua, A.; /CERN; Di Simone, A.; /CERN; Ehrenfeld, E.; /Hamburg U. /DESY; Gallas, M.V.; /CERN; Glazov, A.; /DESY; Marshall, Z.; /Caltech /Nevis Labs, Columbia U.; Mueller, J.; /Pittsburgh U.; Placakyte, R.; /DESY; Rimoldi, A.; /Pavia U. /INFN, Pavia; Savard, P.; /Toronto U.; Tsulaia, V.; /Pittsburgh U.; Waugh, A.; /Sydney U.; Young, C.C.; /SLAC

    2011-11-29

    One of the most time consuming process simulating pp interactions in the ATLAS detector at LHC is the simulation of electromagnetic showers in the calorimeter. In order to speed up the event simulation several parametrisation methods are available in ATLAS. In this paper we present a short description of a frozen shower technique, together with some recent benchmarks and comparison with full simulation. An expected high rate of proton-proton collisions in ATLAS detector at LHC requires large samples of simulated events (Monte Carlo) to study various physics processes. A detailed simulation of particle reactions ('full simulation') in the ATLAS detector is based on GEANT4 and is very accurate. However, due to complexity of the detector, high particle multiplicity and GEANT4 itself, the average CPU time spend to simulate typical QCD event in pp collision is 20 or more minutes for modern computers. During detector simulation the largest time is spend in the calorimeters (up to 70%) most of which is required for electromagnetic particles in the electromagnetic (EM) part of the calorimeters. This is the motivation for fast simulation approaches which reduce the simulation time without affecting the accuracy. Several of fast simulation methods available within the ATLAS simulation framework (standard Athena based simulation program) are discussed here with the focus on the novel frozen shower library (FS) technique. The results obtained with FS are presented here as well.

  9. First GEANT4-based simulation investigation of a Li-coated resistive plate chamber for low-energy neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Rhee, J.T. [Institute for Advanced Physics, Department of Physics, Konkuk University, Seoul 143-701 (Korea, Republic of); Jamil, M., E-mail: mjamil@konkuk.ac.kr [Institute for Advanced Physics, Department of Physics, Konkuk University, Seoul 143-701 (Korea, Republic of); Division of International Studies, University College, Konkuk University, Seoul 143-701 (Korea, Republic of); Jeon, Y.J. [LCD Research Lab, Department of Chemistry, Konkuk University, Seoul 143-701 (Korea, Republic of)

    2013-08-01

    A simulation study of the performance of a single-gap resistive plate chamber coated with Li-layer for the detection of low energy neutrons was performed by means of GEANT4 Monte Carlo code. Low energy neutrons were detected via {sup 7}Li(n, α) {sup 3}He nuclear reaction. To make the detector sensitive to low energy neutrons, Li- coating was employed both on the forward and backward electrodes of the converter. Low energy neutrons were transported onto the Li-coating RPC by GEANT4 MC code. A detector with converter area of 5×5 cm{sup 2} was utilized for this work. The detection response was evaluated as a function of incident low energy neutrons in the range of 25 MeV–100 MeV. The evaluated results predicted higher detection response for the backward-coated converter detector than that of forward coated converter RPC setup. This type of detector can be useful for the detection of low energy neutrons.

  10. Commissioning of a Geant4 based treatment plan simulation tool: linac model and dicom-rt interface

    CERN Document Server

    Cornelius, Iwan; Middlebrook, Nigel; Poole, Christopher; Oborn, Brad; Langton, Christian

    2011-01-01

    A Geant4 based simulation tool has been developed to perform Monte Carlo modelling of a 6 MV VarianTM iX clinac. The computer aided design interface of Geant4 was used to accurately model the LINAC components, including the Millenium multi-leaf collimators (MLCs). The simulation tool was verified via simulation of standard commissioning dosimetry data acquired with an ionisation chamber in a water phantom. Verification of the MLC model was achieved by simulation of leaf leakage measurements performed using GafchromicTM film in a solid water phantom. An absolute dose calibration capability was added by including a virtual monitor chamber into the simulation. Furthermore, a DICOM-RT interface was integrated with the application to allow the simulation of treatment plans in radiotherapy. The ability of the simulation tool to accurately model leaf movements and doses at each control point was verified by simulation of a widely used intensity-modulated radiation therapy (IMRT) quality assurance (QA) technique, the...

  11. Inhomogeneity effect in Varian Trilogy Clinac iX 10 MV photon beam using EGSnrc and Geant4 code system

    Science.gov (United States)

    Yani, S.; Rhani, M. F.; Haryanto, F.; Arif, I.

    2016-08-01

    Treatment fields consist of tissue other than water equivalent tissue (soft tissue, bones, lungs, etc.). The inhomogeneity effect can be investigated by Monte Carlo (MC) simulation. MC simulation of the radiation transport in an absorbing medium is the most accurate method for dose calculation in radiotherapy. The aim of this work is to evaluate the effect of inhomogeneity phantom on dose calculations in photon beam radiotherapy obtained by different MC codes. MC code system EGSnrc and Geant4 was used in this study. Inhomogeneity phantom dimension is 39.5 × 30.5 × 30 cm3 and made of 4 material slices (12.5 cm water, 10 cm aluminium, 5 cm lung and 12.5 cm water). Simulations were performed for field size 4 × 4 cm2 at SSD 100 cm. The spectrum distribution Varian Trilogy Clinac iX 10 MV was used. Percent depth dose (PDD) and dose profile was investigated in this research. The effects of inhomogeneities on radiation dose distributions depend on the amount, density and atomic number of the inhomogeneity, as well as on the quality of the photon beam. Good agreement between dose distribution from EGSnrc and Geant4 code system in inhomogeneity phantom was observed, with dose differences around 5% and 7% for depth doses and dose profiles.

  12. Beta-efficiency of a typical gas-flow ionization chamber using GEANT4 Monte Carlo simulations

    Directory of Open Access Journals (Sweden)

    Hussain Abid

    2011-01-01

    Full Text Available GEANT4 based Monte Carlo simulations have been carried out for the determination of efficiency and conversion factors of a gas-flow ionization chamber for beta particles emitted by 86 different radioisotopes covering the average-b energy range of 5.69 keV-2.061 MeV. Good agreements were found between the GEANT4 predicted values and corresponding experimental data, as well as with EGS4 based calculations. For the reported set of b-emitters, the values of the conversion factor have been established in the range of 0.5×1013-2.5×1013 Bqcm-3/A. The computed xenon-to-air conversion factor ratios have attained the minimum value of 0.2 in the range of 0.1-1 MeV. As the radius and/or volume of the ion chamber increases, conversion factors approach a flat energy response. These simulations show a small, but significant dependence of ionization efficiency on the type of wall material.

  13. Microdosimetry of alpha particles for simple and 3D voxelised geometries using MCNPX and Geant4 Monte Carlo codes.

    Science.gov (United States)

    Elbast, M; Saudo, A; Franck, D; Petitot, F; Desbrée, A

    2012-07-01

    Microdosimetry using Monte Carlo simulation is a suitable technique to describe the stochastic nature of energy deposition by alpha particle at cellular level. Because of its short range, the energy imparted by this particle to the targets is highly non-uniform. Thus, to achieve accurate dosimetric results, the modelling of the geometry should be as realistic as possible. The objectives of the present study were to validate the use of the MCNPX and Geant4 Monte Carlo codes for microdosimetric studies using simple and three-dimensional voxelised geometry and to study their limit of validity in this last case. To that aim, the specific energy (z) deposited in the cell nucleus, the single-hit density of specific energy f(1)(z) and the mean-specific energy were calculated. Results show a good agreement when compared with the literature using simple geometry. The maximum percentage difference found is MCNPX for calculation time is 10 times higher with Geant4 than MCNPX code in the same conditions.

  14. Validation of nuclear models in Geant4 using the halo of a proton pencil beam stopping in water

    CERN Document Server

    Hall, David C; Paganetti, Harald; Gottschalk, Bernard

    2015-01-01

    A proton pencil beam is associated with a surrounding low-dose envelope, originating from nuclear interactions. It is important for treatment planning systems to accurately model this envelope when performing dose calculations for pencil beam scanning treatments, and Monte Carlo (MC) codes are commonly used for this purpose. This work aims to validate the nuclear models employed by the Geant4 MC code, by comparing the simulated absolute dose distribution to a recent experiment of a 177 MeV proton pencil beam stopping in water. Impressive agreement is observed over five orders of magnitude, with both the shape and normalisation well modelled. The normalisations of two depth dose curves are lower than experiment, though this could be explained by an experimental positioning error. The Geant4 neutron production model is also verified in the distal region. The entrance dose is poorly modelled, suggesting an unaccounted upstream source of low-energy protons. Recommendations are given for a follow-up experiment whi...

  15. A Physical Model of Electromagnetic Force from PEMA Acted on Metal Projectiles

    Institute of Scientific and Technical Information of China (English)

    HU Jin-suo; YANG Zuo-bin

    2007-01-01

    Electromagnetic armor is a new conceptual combat vehicle technology, which improves remarkably the defensive capability and maneuverability of vehicles. The authors present definitely to apply the electromagnetic theory to analyze the electromagnetic armor. Based on electromagnetics, the experienced expression of projectile and the physical model of PEMA (passive electromagnetic armor) are obtained when electric current flows through the system, and a computer simulation is given.

  16. A Geant4-based Simulation to Evaluate the Feasibility of Using Nuclear Resonance Fluorescence (NRF) in Determining Atomic Compositions of Body Tissue in Cancer Diagnostics and Irradiation

    Science.gov (United States)

    Gilbo, Yekaterina; Wijesooriya, Krishni; Liyanage, Nilanga

    2017-01-01

    Customarily applied in homeland security for identifying concealed explosives and chemical weapons, NRF (Nuclear Resonance Fluorescence) may have high potential in determining atomic compositions of body tissue. High energy photons incident on a target excite the target nuclei causing characteristic re-emission of resonance photons. As the nuclei of each isotope have well-defined excitation energies, NRF uniquely indicates the isotopic content of the target. NRF radiation corresponding to nuclear isotopes present in the human body is emitted during radiotherapy based on Bremsstrahlung photons generated in a linear electron accelerator. We have developed a Geant4 simulation in order to help assess NRF capabilities in detecting, mapping, and characterizing tumors. We have imported a digital phantom into the simulation using anatomical data linked to known chemical compositions of various tissues. Work is ongoing to implement the University of Virginia's cancer center treatment setup and patient geometry, and to collect and analyze the simulation's physics quantities to evaluate the potential of NRF for medical imaging applications. Preliminary results will be presented.

  17. Reaction Cross Section Calculations in Neutron Induced Reactions and GEANT4 Simulation of Hadronic Interactions for the Reactor Moderator Material BeO

    Directory of Open Access Journals (Sweden)

    Veli ÇAPALI

    2016-05-01

    Full Text Available BeO is one of the most common moderator material for neutron moderation; due to its high density, neutron capture cross section and physical-chemical properties that provides usage at elevated temperatures. As it’s known, for various applications in the field of reactor design and neutron capture, reaction cross–section data are required. The cross–sections of (n,α, (n,2n, (n,t, (n,EL and (n,TOT reactions for 9Be and 16O nuclei have been calculated by using TALYS 1.6 Two Component Exciton model and EMPIRE 3.2 Exciton model in this study. Hadronic interactions of low energetic neutrons and generated isotopes–particles have been investigated for a situation in which BeO was used as a neutron moderator by using GEANT4, which is a powerful simulation software. In addition, energy deposition along BeO material has been obtained. Results from performed calculations were compared with the experimental nuclear reaction data exist in EXFOR.

  18. Geant4 simulation of clinical proton and carbon ion beams for the treatment of ocular melanomas with the full 3-D pencil beam scanning system

    Energy Technology Data Exchange (ETDEWEB)

    Farina, Edoardo; Riccardi, Cristina; Rimoldi, Adele; Tamborini, Aurora [University of Pavia and the INFN section of Pavia, via Bassi 6, 27100 Pavia (Italy); Piersimoni, Pierluigi [Division of Radiation Research, Loma Linda University, Loma Linda, CA 92354 (United States); Ciocca, Mario [Medical Physics Unit, CNAO Foundation, Strada Campeggi 53, 27100 Pavia (Italy)

    2015-07-01

    This work investigates the possibility to use carbon ion beams delivered with active scanning modality, for the treatment of ocular melanomas at the Centro Nazionale di Adroterapia Oncologica (CNAO) in Pavia. The radiotherapy with carbon ions offers many advantages with respect to the radiotherapy with protons or photons, such as a higher relative radio-biological effectiveness (RBE) and a dose release better localized to the tumor. The Monte Carlo (MC) Geant4 10.00 patch-03 toolkit is used to reproduce the complete CNAO extraction beam line, including all the active and passive components characterizing it. The simulation of proton and carbon ion beams and radiation scanned field is validated against CNAO experimental data. For the irradiation study of the ocular melanoma an eye-detector, representing a model of a human eye, is implemented in the simulation. Each element of the eye is reproduced with its chemical and physical properties. Inside the eye-detector a realistic tumor volume is placed and used as the irradiation target. A comparison between protons and carbon ions eye irradiations allows to study possible treatment benefits if carbon ions are used instead of protons. (authors)

  19. Comparative study of RBE and cell survival fractions for $^{1}$H, $^{4}$He, $^{12}$C and $^{16}$O beams using Geant4 and Microdosimetric Kinetic model

    CERN Document Server

    Burigo, Lucas; Mishustin, Igor; Bleicher, Marcus

    2014-01-01

    Beams of $^{4}$He and $^{16}$O nuclei are considered for ion-beam cancer therapy as alternative options to protons and $^{12}$C nuclei. Spread-out Bragg peak (SOBP) distributions of physical dose and relative biological effectiveness for 10% survival are calculated by means of our Geant4-based Monte Carlo model for Heavy Ion Therapy (MCHIT) and the modified microdosimetric kinetic model. The depth distributions of cell survival fractions are calculated for $^{1}$H, $^{4}$He, $^{12}$C and $^{16}$O for tissues with normal (HSG cells), low and high radiosensitivity. In each case the cell survival fractions were compared separately for the target volume, behind and in front of it. In the case of normal radiosensitivity $^{4}$He and $^{12}$C better spare tissues in the entrance channel compared to protons and $^{16}$O. The cell survival fractions calculated, respectively, for the entrance channel and target volume are similar for $^{4}$He and $^{12}$C. When it is important to spare healthy tissues located after th...

  20. Fundamentals of physics II electromagnetism, optics, and quantum mechanics

    CERN Document Server

    Shankar, R

    2016-01-01

    R. Shankar, a well-known physicist and contagiously enthusiastic educator, was among the first to offer a course through the innovative Open Yale Course program. His popular online video lectures on introductory physics have been viewed over a million times. In this second book based on his online Yale course, Shankar explains essential concepts, including electromagnetism, optics, and quantum mechanics. The book begins at the simplest level, develops the basics, and reinforces fundamentals, ensuring a solid foundation in the principles and methods of physics. It provides an ideal introduction for college-level students of physics, chemistry, and engineering; for motivated AP Physics students; and for general readers interested in advances in the sciences.

  1. A physically motivated quantization of the electromagnetic field

    Science.gov (United States)

    Bennett, Robert; Barlow, Thomas M.; Beige, Almut

    2016-01-01

    The notion that the electromagnetic field is quantized is usually inferred from observations such as the photoelectric effect and the black-body spectrum. However accounts of the quantization of this field are usually mathematically motivated and begin by introducing a vector potential, followed by the imposition of a gauge that allows the manipulation of the solutions of Maxwell’s equations into a form that is amenable for the machinery of canonical quantization. By contrast, here we quantize the electromagnetic field in a less mathematically and more physically motivated way. Starting from a direct description of what one sees in experiments, we show that the usual expressions of the electric and magnetic field observables follow from Heisenberg’s equation of motion. In our treatment, there is no need to invoke the vector potential in a specific gauge and we avoid the commonly used notion of a fictitious cavity that applies boundary conditions to the field.

  2. γ全吸收型探测装置中子束流监视器的Geant4模拟%Geant4 Simulation of Neutron Beam Monitor in Gamma-Ray Total Absorption Facility

    Institute of Scientific and Technical Information of China (English)

    苏明; 仲启平; 郑玉来; 张奇玮; 阮锡超; 周祖英; 孔祥忠

    2009-01-01

    The relative detection efficiency of a lithium glass detector used as a neutron beam monitor in gamma-ray total absorption facility was simulated by Geant4. The neutron detection efficiency of the lithium glass detector was obtained between 10 keV and 1 MeV. Some factors affecting the efficiency were analyzed. The effect of the time delay caused by the elastic scattering upon TOF (time-of-flight) measurement, and the n-γ discrimination in different thickness lithium glass were discussed. The work will be helpful to understand better the neutron time of flight spectrum and energy spectrum from Li-glass detector which is used as a monitor of keV neutron source.%利用Geant4模拟了γ全吸收型探测装置中用于中子束流监视的锂玻璃探测器的相对探测效率,给出了锂玻璃探测器在10 keV~1 MeV区间的中子探测效率,并对影响探测效率的相关因素进行了分析,讨论了弹性散射引起的时间滞后对TOF(time-of-flight)测量的影响和不同厚度锂玻璃探测器的n-γ分辨效果.在未来使用锂玻璃探测器作为keV中子源监视器时,这项工作将为更好地理解相关中子飞行时间谱和能谱提供依据.

  3. Spallation Source Modelling for an ADS Using the MCNPX and GEANT4 Packages for Sensitivity Analysis of Reactivity

    Science.gov (United States)

    Antolin, M. Q.; Marinho, F.; Palma, D. A. P.; Martinez, A. S.

    2014-04-01

    A simulation for the time evolution of the MYRRHA conceptual reactor was developed. The SERPENT code was used to simulate the nuclear fuel depletion and the spallation source which drives the system was simulated using both MCNPX and GEANT4 packages. The obtained results for the neutron energy spectrum from the spallation are coherent with each other and were used as input for the SERPENT code which simulated a constant power operation regime. The obtained results show that the criticality of the system is not sensitive to the spallation models employed and only relative small deviations with respect to the inverse kinetic model coming from the point kinetic equations proposed by Gandini were observed.

  4. Simulation of the Production of Secondary Particles from a Neutron Beam on Polyethylene Targets using the GEANT4 Simulation Tool

    CERN Document Server

    Ilgner, C

    2003-01-01

    In view of a beam test of RadFET semiconductor detectors and optically stimulated luminescence (OSL) detectors as on-line dosimeters for radiation monitoring purposes in the caverns of the Large Hadron Collider (LHC) experiments, a simulation on the production of secondary particles from a neutron beam on a polyethylene target was carried out. We describe the yield of recoil protons, scattered neutrons as well as electrons, positrons and photons, when neutrons of an average energy of 20 MeV hit polyethylene targets of several thicknesses. The simulation was carried out using the latest release 5.2 of the GEANT4 detector description and simulation tool, including advanced hadron interaction models.

  5. The effect of heavy metal in CMOS on neutron induced single event upset simulated with Geant4

    CERN Document Server

    Zhang, Huan; Chen, Wei; Yang, Shan-chao

    2015-01-01

    Local metal interconnection is widely used in modern complementary metal oxide semiconductor (CMOS) technology. The most frequently used local materials are some heavy metals, such as tungsten (W) or copper (Cu). It's well known that single event upset (SEU) could occur in a CMOS under neutron exposure. In this paper the rectangular parallelepiped (RPP) method is used to investigate the SEU response of a typical CMOS. SEU induced by 1$\\sim$14\\:MeV neutrons are simulated with Geant4 and the cross sections are calculated. The results show that only in the structure with W, secondary particle $\\alpha$ is created and SEUs are generated when the energy of neutron is less than $4$\\:MeV.

  6. The radiation environment on the surface of Mars - Numerical calculations of the galactic component with GEANT4/PLANETOCOSMICS

    Science.gov (United States)

    Matthiä, Daniel; Berger, Thomas

    2017-08-01

    Galactic cosmic radiation and secondary particles produced in the interaction with the atmosphere lead to a complex radiation field on the Martian surface. A workshop (;1st Mars Space Radiation Modeling Workshop;) organized by the MSL-RAD science team was held in June 2016 in Boulder with the goal to compare models capable to predict this radiation field with each other and measurements from the RAD instrument onboard the curiosity rover taken between November 15, 2015 and January 15, 2016. In this work the results of PLANETOCOSMICS/GEANT4 contributed to the workshop are presented. Calculated secondary particle spectra on the Martian surface are investigated and the radiation field's directionality of the different particles in dependence on the energy is discussed. Omnidirectional particle fluxes are used in combination with fluence to dose conversion factors to calculate absorbed dose rates and dose equivalent rates in a slab of tissue.

  7. Geant4 Simulation Study of Dose Distribution and Energy Straggling for Proton and Carbon Ion Beams in Water

    Directory of Open Access Journals (Sweden)

    Zhao Qiang

    2016-01-01

    Full Text Available Dose distribution and energy straggling for proton and carbon ion beams in water are investigated by using a hadrontherapy model based on the Geant4 toolkit. By gridding water phantom in N×N×N voxels along X, Y and Z axes, irradiation dose distribution in all the voxels is calculated. Results indicate that carbon ion beams have more advantages than proton beams. Proton beams have bigger width of the Bragg peak and broader lateral dose distribution than carbon ion beams for the same position of Bragg peaks. Carbon ion has a higher local ionization density and produces more secondary electrons than proton, so carbon ion beams can achieve a higher value of relative biological effectiveness.

  8. The performance of a new Geant4 Bertini intra-nuclear cascade model in high throughput computing (HTC) cluster architecture

    Energy Technology Data Exchange (ETDEWEB)

    Aatos, Heikkinen; Andi, Hektor; Veikko, Karimaki; Tomas, Linden [Helsinki Univ., Institute of Physics (Finland)

    2003-07-01

    We study the performance of a new Bertini intra-nuclear cascade model implemented in the general detector simulation tool-kit Geant4 with a High Throughput Computing (HTC) cluster architecture. A 60 node Pentium III open-Mosix cluster is used with the Mosix kernel performing automatic process load-balancing across several CPUs. The Mosix cluster consists of several computer classes equipped with Windows NT workstations that automatically boot, daily and become nodes of the Mosix cluster. The models included in our study are a Bertini intra-nuclear cascade model with excitons, consisting of a pre-equilibrium model, a nucleus explosion model, a fission model and an evaporation model. The speed and accuracy obtained for these models is presented. (authors)

  9. A GEANT4 study on the time resolution of a fast plastic scintillator read out by a G-APD

    Energy Technology Data Exchange (ETDEWEB)

    Sedlak, K., E-mail: kamil.sedlak@psi.ch [Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Stoykov, A.; Scheuermann, R. [Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland)

    2012-12-22

    The time resolution of a fast scintillation counter, consisting of a plastic scintillator read out by a Geiger-mode Avalanche Photodiode, is studied over a wide range of the number of detected photons (primary photoelectrons) using the GEANT4 simulation toolkit. Different timing definitions such as first photon detection, leading edge and constant fraction discrimination are considered. In the latter case the predictions are compared with the existing experimental data. We also show that due to the finite scintillation rise time, finite scintillator dimensions and also due to the finite single photon time resolution in G-APD cells, the time resolution for the first detected photon in real detectors substantially deviates from the {sigma}{approx}1/N{sub phe} dependence, theoretically predicted for a scintillator with zero rise time.

  10. A GEANT4 study on the time resolution of a fast plastic scintillator read out by a G-APD

    Science.gov (United States)

    Sedlak, K.; Stoykov, A.; Scheuermann, R.

    2012-12-01

    The time resolution of a fast scintillation counter, consisting of a plastic scintillator read out by a Geiger-mode Avalanche Photodiode, is studied over a wide range of the number of detected photons (primary photoelectrons) using the GEANT4 simulation toolkit. Different timing definitions such as first photon detection, leading edge and constant fraction discrimination are considered. In the latter case the predictions are compared with the existing experimental data. We also show that due to the finite scintillation rise time, finite scintillator dimensions and also due to the finite single photon time resolution in G-APD cells, the time resolution for the first detected photon in real detectors substantially deviates from the σ˜1/Nphe dependence, theoretically predicted for a scintillator with zero rise time.

  11. The performance of a new Geant4 Bertini intra-nuclear cascade model in high throughput computing (HTC) cluster architecture

    Energy Technology Data Exchange (ETDEWEB)

    Aatos, Heikkinen; Andi, Hektor; Veikko, Karimaki; Tomas, Linden [Helsinki Univ., Institute of Physics (Finland)

    2003-07-01

    We study the performance of a new Bertini intra-nuclear cascade model implemented in the general detector simulation tool-kit Geant4 with a High Throughput Computing (HTC) cluster architecture. A 60 node Pentium III open-Mosix cluster is used with the Mosix kernel performing automatic process load-balancing across several CPUs. The Mosix cluster consists of several computer classes equipped with Windows NT workstations that automatically boot, daily and become nodes of the Mosix cluster. The models included in our study are a Bertini intra-nuclear cascade model with excitons, consisting of a pre-equilibrium model, a nucleus explosion model, a fission model and an evaporation model. The speed and accuracy obtained for these models is presented. (authors)

  12. Performance evaluation of multi sampling ionization chamber for heavy ion beams by comparison with GEANT4 simulation

    Science.gov (United States)

    Kanke, Yuki; Himac H093 Collaboration

    2014-09-01

    In high-energy heavy-ion accelerator facilities, multi sampling ionization chambers are often used for the identification of the atomic number Z by detecting the energy deposit in it. In the study at GSI, the picture of the escape of secondary electrons, δ rays, from the ionization chamber explains the experimental data of pulse-height resolution. If this picture is correct, the pulse-height resolution should depend on the effective area of the ionization chamber. The experiment have been performed at NIRS-HIMAC. The pulse-height resolutions of two ionization chambers with different effective area were compared by using a 400-MeV/u Ni beam and their fragments. The difference in the pulse-height resolutions was observed. By comparison with the GEANT4 simulation including the δ-rays emission, the performance of the ionization chamber have been evaluated.

  13. Strong interactions and electromagnetism in low-energy hadron physics

    Energy Technology Data Exchange (ETDEWEB)

    Kubis, B.

    2002-10-01

    In the present work, we study various aspects of the entanglement of the strong and electromagnetic interactions as it is manifest in low-energy hadron physics. In the framework of chiral perturbation theory, two aspects are investigated: the test of the structure of baryons as probed by external electromagnetic currents, and the modification of reactions mediated by the strong interactions in the presence of internal (virtual) photons. In the first part of this work, we study the electromagnetic form factors of nucleons and the ground state baryon octet, as well as strangeness form factors of the nucleon. Emphasis is put on the comparison of a new relativistic scheme for the calculation of loop diagrams to the heavy-baryon formalism, and on the convergence of higher-order corrections in both schemes. The new scheme is shown to yield both a phenomenologically more successful description of the data and better convergence behaviour. In the second part, we study isospin violation in pion-kaon scattering as mediated by virtual photon effects and the light quark mass difference. This investigation is of particular importance for the extraction of scattering lengths from measurements of lifetime and energy levels in pion-kaon atoms. The isospin breaking corrections are shown to be small and sufficiently well under control. (orig.)

  14. Assessment and improvements of Geant4 hadronic models in the context of prompt-gamma hadrontherapy monitoring

    Science.gov (United States)

    Dedes, G.; Pinto, M.; Dauvergne, D.; Freud, N.; Krimmer, J.; Létang, J. M.; Ray, C.; Testa, E.

    2014-04-01

    Monte Carlo simulations are nowadays essential tools for a wide range of research topics in the field of radiotherapy. They also play an important role in the effort to develop a real-time monitoring system for quality assurance in proton and carbon ion therapy, by means of prompt-gamma detection. The internal theoretical nuclear models of Monte Carlo simulation toolkits are of decisive importance for the accurate description of neutral or charged particle emission, produced by nuclear interactions between beam particles and target nuclei. We assess the performance of Geant4 nuclear models in the context of prompt-gamma emission, comparing them with experimental data from proton and carbon ion beams. As has been shown in the past and further indicated in our study, the prompt-gamma yields are consistently overestimated by Geant4 by a factor of about 100% to 200% over an energy range from 80 to 310 MeV/u for the case of 12C, and to a lesser extent for 160 MeV protons. Furthermore, we focus on the quantum molecular dynamics (QMD) modeling of ion-ion collisions, in order to optimize its description of light nuclei, which are abundant in the human body and mainly anticipated in hadrontherapy applications. The optimization has been performed by benchmarking QMD free parameters with well established nuclear properties. In addition, we study the effect of this optimization on charged particle emission. With the usage of the proposed parameter values, discrepancies reduce to less than 70%, with the highest values being attributed to the nucleon-ion induced prompt-gammas. This conclusion, also confirmed by the disagreement we observe in the case of proton beams, indicates the need for further investigation on nuclear models which describe proton and neutron induced nuclear reactions.

  15. An investigation on the radiation sensitivity of DNA conformations to {sup 60}Co gamma rays by using Geant4 toolkit

    Energy Technology Data Exchange (ETDEWEB)

    Semsarha, F. [Institute of Biochemistry and Biophysics (IBB), University of Tehran, P.O. Box 13145-1384, Tehran (Iran, Islamic Republic of); Goliaei, B., E-mail: goliaei@ibb.ut.ac.ir [Institute of Biochemistry and Biophysics (IBB), University of Tehran, P.O. Box 13145-1384, Tehran (Iran, Islamic Republic of); Raisali, G.; Khalafi, H. [Radiation Applications Research School, Nuclear Science and Technology Research Institute, P.O. Box 11365-3486, Tehran (Iran, Islamic Republic of); Mirzakhanian, L. [Medical Physics Unit, McGill University, 1650 Cedar Avenue, Montreal, Quebec (Canada)

    2014-03-15

    To investigate the impact of conformational properties of genetic material of living cells on radiation-induced DNA damage, single strand breaks (SSB), double strand breaks (DSB) and some microdosimetric quantities of A, B and Z-DNA conformations caused by {sup 60}Co gamma rays, have been calculated. Based on a previous B-DNA geometrical model, models of A and Z forms have been developed. Simple 34 base pairs segments of each model repeated in high number and secondary electron spectrum of {sup 60}Co gamma rays have been simulated in a volume of a typical animal cell nucleus. All simulations in this study have been performed by using the Geant4 (GEometry ANd Tracking 4)-DNA extension of the Geant4 toolkit. The results showed that, B-DNA has the lowest yield of simple strand breaks with 2.23 × 10{sup −10} Gy{sup −1} Da{sup −1} and 1.0 × 10{sup −11} Gy{sup −1} Da{sup −1} for the SSB and DSB damage yield, respectively. The A-DNA has the highest SSB yield with 3.59 × 10{sup −10} Gy{sup −1} Da{sup −1} and the Z-DNA has the highest DSB yields with 1.8 × 10{sup −11} Gy{sup −1} Da{sup −1}. It has been concluded that there is a direct correlation between the hit probability, mean specific imparted energy and SSB yield in each model of DNA. Moreover, there is a direct correlation between the DSB yield and both the mean lineal energy and topological characteristics of each model.

  16. Validation of electromagnetic and hadronic physical processes in the interaction of a proton beam with matter: A Solar Particle Events case study with an Al slab

    Science.gov (United States)

    Loffredo, Filomena; Vardaci, Emanuele; Quarto, Maria; Roca, Vincenzo; Pugliese, Mariagabriella

    2017-01-01

    In the study of the effectiveness of shielding materials against radiations, one of the main steps concerns with the validation of models describing the interaction processes of the radiation of interest with the material chosen for the shielding. This paper shows the results of the validation of electromagnetic and hadronic processes with the aim to contribute to the study of protection for astronauts against the radiations due to the Solar Particle Events, in particular to the selection of the optimal material for radiation shielding. The physics case deals with the interaction of a proton beam with an aluminum slab about 20 g/cm2 thick. Two specific applications, STP and DOSE, were developed by using Geant4 package. STP computes the radiations produced in the interaction and their stopping power; DOSE computes the absorbed dose from the stopping power calculated by STP. The validation process was performed in two steps. In the first one, the output of the STP code is compared to data available on NIST database; in the second one, the absorbed dose computed with DOSE is compared to the dose gathered during an experiment performed at the NASA Space Radiation Laboratory involving the bombardment of an aluminum slab with a 1 GeV proton beam. The computing model has allowed us to correlate the size of the impinging beam profile to the dose measured before and after an Al slab. The sharp increase of the dose in the position right after the slab might be due to the stochastic nature of the trajectories of charged ions in matter which makes the radiation to emerge with non-zero transverse linear momentum. From the case examined here, we conclude that aluminum is not an efficient material for Solar Particle Event shielding.

  17. Physics of electromagnetic and material stresses in optical manipulation

    Science.gov (United States)

    Kemp, Brandon A.; Sheppard, Cheyenne J.

    2015-08-01

    Modeling the dynamics of optical manipulation experiments relies upon a precise mathematical representation of electromagnetic fields and the interpretation of optical momentum and stresses in materials. However, the momentum of light within media has been an issue of debate over the past century. Multiple energy-momentum models have been advanced, each, under certain conditions, agreeing with experimental observation and mathematically consistent with classical electromagnetism. The modern view is that the various formulations of electrodynamics represent different divisions of the total energy-momentum tensor, with the separation of field and matter being ambiguous. Recently, a proposed view of photon momentum identified two leading forms as the kinetic and canonical momenta. The Abraham momentum is responsible for the overall center-of-mass translation of a material, while the Minkowski momentum is responsible for translations with respect to the surrounding medium. However, the Abraham momentum corresponds to multiple, unique electromagnetic energy-momentum tensors that attempt to separate field from material responses (e.g. Abraham, Chu, and Einstein-Laub). However, only the form of the kinetic momentum density has been revealed, while the formulation that uniquely separates the kinetic stress tensor has remained ambiguous. In this correspondence, multiple formulations are considered within the framework of relativistic electrodynamics. We apply various mathematical techniques to identify the kinetic subsystem of electrodynamics. While optical manipulation is usually modeled using a stationary medium approximation, the lessons from relativistic electrodynamics reveal a specific distribution of electromagnetic stress in media. The physics of optical and static manipulation of dielectric particles are described within this framework.

  18. Few-body physics with the electromagnetic probe: Theoretical issues

    Energy Technology Data Exchange (ETDEWEB)

    Orlandini, G. [Dipartimento di Fisica, Universita di Trento, 38123 Trento (Italy); Istituto Nazionale di Fisica Nucleare, Gruppo Collegato di Trento, 38123 Trento (Italy)

    2011-09-15

    This review intends to stress some of the questions of fundamental nature that modern nuclear physics faces. The contributions of the theory of few-body systems as well as the role of the electromagnetic probe to their solution is emphasized. The focus is on A > 2 systems. The nuclear quantum mechanical many-body problem has to undergo to some approximations to become solvable. The amount of error generated by these approximations is very hard to estimate and resembles the systematic error of experimental data. It will be shown in the section 2, that the field of few-body physics offers theories, where such errors can be avoided, or at least reliably estimated. This makes few-nucleon systems a privileged test ground for the QCD fundamentals of nuclear physics. The choice of the experimental probe is also very important. In section 3 it will be argued that the electromagnetic (e.m.) probe is the best one. In fact, differently from the hadron probe, the e.m. one is sensitive to explicit as well as implicit degrees of freedom (the weak probe has similar characteristics, but too small cross sections). In section 4 a few selected theoretical results, obtained in the last years, will be presented. The choice has been done with the aim to illustrate some of the current important issues that need an answer. These answers can of course come only from a meaningful (unambiguous) comparison between theory and experiment. Finally section 5 will be devoted to a few considerations about the perspectives of the field of e.m. interactions with few-body systems, in particular at low energy and momenta

  19. First experience of vectorizing electromagnetic physics models for detector simulation

    Energy Technology Data Exchange (ETDEWEB)

    Amadio, G. [Sao Paulo State U.; Apostolakis, J. [CERN; Bandieramonte, M. [Catania Astrophys. Observ.; Bianchini, C. [Mackenzie Presbiteriana U.; Bitzes, G. [CERN; Brun, R. [CERN; Canal, P. [Fermilab; Carminati, F. [CERN; Licht, J.de Fine [U. Copenhagen (main); Duhem, L. [Intel, Santa Clara; Elvira, D. [Fermilab; Gheata, A. [CERN; Jun, S. Y. [Fermilab; Lima, G. [Fermilab; Novak, M. [CERN; Presbyterian, M. [Bhabha Atomic Res. Ctr.; Shadura, O. [CERN; Seghal, R. [Bhabha Atomic Res. Ctr.; Wenzel, S. [CERN

    2015-12-23

    The recent emergence of hardware architectures characterized by many-core or accelerated processors has opened new opportunities for concurrent programming models taking advantage of both SIMD and SIMT architectures. The GeantV vector prototype for detector simulations has been designed to exploit both the vector capability of mainstream CPUs and multi-threading capabilities of coprocessors including NVidia GPUs and Intel Xeon Phi. The characteristics of these architectures are very different in terms of the vectorization depth, parallelization needed to achieve optimal performance or memory access latency and speed. An additional challenge is to avoid the code duplication often inherent to supporting heterogeneous platforms. In this paper we present the first experience of vectorizing electromagnetic physics models developed for the GeantV project.

  20. First experience of vectorizing electromagnetic physics models for detector simulation

    Science.gov (United States)

    Amadio, G.; Apostolakis, J.; Bandieramonte, M.; Bianchini, C.; Bitzes, G.; Brun, R.; Canal, P.; Carminati, F.; de Fine Licht, J.; Duhem, L.; Elvira, D.; Gheata, A.; Jun, S. Y.; Lima, G.; Novak, M.; Presbyterian, M.; Shadura, O.; Seghal, R.; Wenzel, S.

    2015-12-01

    The recent emergence of hardware architectures characterized by many-core or accelerated processors has opened new opportunities for concurrent programming models taking advantage of both SIMD and SIMT architectures. The GeantV vector prototype for detector simulations has been designed to exploit both the vector capability of mainstream CPUs and multi-threading capabilities of coprocessors including NVidia GPUs and Intel Xeon Phi. The characteristics of these architectures are very different in terms of the vectorization depth, parallelization needed to achieve optimal performance or memory access latency and speed. An additional challenge is to avoid the code duplication often inherent to supporting heterogeneous platforms. In this paper we present the first experience of vectorizing electromagnetic physics models developed for the GeantV project.

  1. Geant4 simulation for a study of a possible use of carbon ions pencil beam for the treatment of ocular melanomas with the active scanning system at CNAO Centre

    Energy Technology Data Exchange (ETDEWEB)

    Farina, E. [University of Pavia-Department of Physics, via Bassi 6, 27100 Pavia (Italy); Piersimoni, P. [Division of Radiation Research, Loma Linda University, Loma Linda, CA 92354 (United States); Riccardi, C.; Rimoldi, A.; Tamborini, A. [University of Pavia-Department of Physics, via Bassi 6, 27100 Pavia (Italy); INFN Section of Pavia, via Bassi 6, 27100 Pavia (Italy); Ciocca, M. [Medical Physics Unit, Centro Nazionale di Adroterapia Oncologica - CNAO Foundation, Strada Campeggi 53, 27100 Pavia (Italy)

    2015-07-01

    The aim of this work is to validate the Geant4 application reproducing the CNAO (National Centre for Oncological Hadrontherapy) beamline and to study of a possible use of carbon ion pencil beams for the treatment of ocular melanomas at the CNAO Centre. The promising aspect of carbon ions radiotherapy for the treatment of this disease lies in its superior relative radiobiological effectiveness (RBE). The Monte Carlo Geant4 toolkit is used to simulate the complete CNAO extraction beamline, with the active and passive components along it. A human eye modeled detector, including a realistic target tumor volume, is used as target. Cross check with previous studies at CNAO using protons allows comparisons on possible benefits on using such a technique with respect to proton beams. Before the eye-detector irradiation a validation of the Geant4 simulation with CNAO experimental data is carried out with both carbon ions and protons. Important beam parameters such as the transverse FWHM and scanned radiation field 's uniformity are tested within the simulation and compared with experimental measurements at CNAO Centre. The physical processes involved in secondary particles generation by carbon ions and protons in the eye-detector are reproduced to take into account the additional dose to the primary beam given to irradiated eye's tissues. A study of beam shaping is carried out to produce a uniform 3D dose distribution (shaped on the tumor) by the use of a spread out Bragg peak. The eye-detector is then irradiated through a two dimensional transverse beam scan at different depths. In the use case the eye-detector is rotated of an angle of 40 deg. in the vertical direction, in order to mis-align the tumor from healthy tissues in front of it. The treatment uniformity on the tumor in the eye-detector is tested. For a more quantitative description of the deposited dose in the eye-detector and for the evaluation of the ratio between the dose deposited in the tumor and

  2. Simulation of neutron multiplicity measurements using Geant4. Open source software for nuclear arms control

    Energy Technology Data Exchange (ETDEWEB)

    Kuett, Moritz

    2016-07-07

    Nuclear arms control, including nuclear safeguards and verification technologies for nuclear disarmament typically use software as part of many different technological applications. This thesis proposes to use three open source criteria for such software, allowing users and developers to have free access to a program, have access to the full source code and be able to publish modifications for the program. This proposition is presented and analyzed in detail, together with the description of the development of ''Open Neutron Multiplicity Simulation'', an open source software tool to simulate neutron multiplicity measurements. The description includes physical background of the method, details of the developed program and a comprehensive set of validation calculations.

  3. Calibration and GEANT4 Simulations of the Phase II Proton Compute Tomography (pCT) Range Stack Detector

    Energy Technology Data Exchange (ETDEWEB)

    Uzunyan, S. A. [Northern Illinois Univ., DeKalb, IL (United States); Blazey, G. [Northern Illinois Univ., DeKalb, IL (United States); Boi, S. [Northern Illinois Univ., DeKalb, IL (United States); Coutrakon, G. [Northern Illinois Univ., DeKalb, IL (United States); Dyshkant, A. [Northern Illinois Univ., DeKalb, IL (United States); Francis, K. [Northern Illinois Univ., DeKalb, IL (United States); Hedin, D. [Northern Illinois Univ., DeKalb, IL (United States); Johnson, E. [Northern Illinois Univ., DeKalb, IL (United States); Kalnins, J. [Northern Illinois Univ., DeKalb, IL (United States); Zutshi, V. [Northern Illinois Univ., DeKalb, IL (United States); Ford, R. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Rauch, J. E. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Rubinov, P. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Sellberg, G. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Wilson, P. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Naimuddin, M. [Univ. of Delhi, New Delhi (India)

    2015-12-29

    Northern Illinois University in collaboration with Fermi National Accelerator Laboratory (FNAL) and Delhi University has been designing and building a proton CT scanner for applications in proton treatment planning. The Phase II proton CT scanner consists of eight planes of tracking detectors with two X and two Y coordinate measurements both before and after the patient. In addition, a range stack detector consisting of a stack of thin scintillator tiles, arranged in twelve eight-tile frames, is used to determine the water equivalent path length (WEPL) of each track through the patient. The X-Y coordinates and WEPL are required input for image reconstruction software to find the relative (proton) stopping powers (RSP) value of each voxel in the patient and generate a corresponding 3D image. In this Note we describe tests conducted in 2015 at the proton beam at the Central DuPage Hospital in Warrenville, IL, focusing on the range stack calibration procedure and comparisons with the GEANT~4 range stack simulation.

  4. Microdosimetry of radiation fields from therapeutic C-12 beams in water: a study with Geant4 toolkit

    CERN Document Server

    Burigo, Lucas; Mishustin, Igor; Bleicher, Marcus

    2013-01-01

    We model the responses of Tissue-Equivalent Proportional Counters (TEPC) to radiation fields of therapeutic C-12 beams in a water phantom and to quasi-monoenergetic neutrons in a PMMA phantom. Simulations are performed with the Monte Carlo for Heavy Ion Therapy (MCHIT) model based on the Geant4 toolkit. The shapes of the calculated lineal energy spectra agree well with measurements in both cases. Measurements on the axis of a narrow C-12 beam with its width smaller than the TEPC diameter are studied in detail. The relation between LET and measured frequency-mean lineal energy yf is discussed. It is found that the choice of the nuclear fragmentation model used in MCHIT simulations has a relatively small influence on the calculated total lineal energy spectra. However, the shapes of the spectra measured with C-12 beams are better described by MCHIT calculations which take into account the production of delta-electrons. The validation of MCHIT with neutron beams gives us confidence in estimating the contribution...

  5. 3D polymer gel dosimetry and Geant4 Monte Carlo characterization of novel needle based X-ray source

    Science.gov (United States)

    Liu, Y.; Sozontov, E.; Safronov, V.; Gutman, G.; Strumban, E.; Jiang, Q.; Li, S.

    2010-11-01

    In the recent years, there have been a few attempts to develop a low energy x-ray radiation sources alternative to conventional radioisotopes used in brachytherapy. So far, all efforts have been centered around the intent to design an interstitial miniaturized x-ray tube. Though direct irradiation of tumors looks very promising, the known insertable miniature x-ray tubes have many limitations: (a) difficulties with focusing and steering the electron beam to the target; (b)necessity to cool the target to increase x-ray production efficiency; (c)impracticability to reduce the diameter of the miniaturized x-ray tube below 4mm (the requirement to decrease the diameter of the x-ray tube and the need to have a cooling system for the target have are mutually exclusive); (c) significant limitations in changing shape and energy of the emitted radiation. The specific aim of this study is to demonstrate the feasibility of a new concept for an insertable low-energy needle x-ray device based on simulation with Geant4 Monte Carlo code and to measure the dose rate distribution for low energy (17.5 keV) x-ray radiation with the 3D polymer gel dosimetry.

  6. Determination of tungsten target parameters for transmission X-ray tube: A simulation study using Geant4

    Energy Technology Data Exchange (ETDEWEB)

    Nasseri, Mohammad M. [School of Plasma Physics and Nuclear Fusion, Institute of Nuclear Science and Technology (AEOI), Tehran (Iran, Islamic Republic of)

    2016-06-15

    Transmission X-ray tubes based on carbon nanotube have attracted significant attention recently. In most of these tubes, tungsten is used as the target material. In this article, the well-known simulator Geant4 was used to obtain some of the tungsten target parameters. The optimal thickness for maximum production of usable X-rays when the target is exposed to electron beams of different energies was obtained. The linear variation of optimal thickness of the target for different electron energies was also obtained. The data obtained in this study can be used to design X-ray tubes. A beryllium window was considered for the X-ray tube. The X-ray energy spectra at the moment of production and after passing through the target and window for different electron energies in the 30-110 keV range were also obtained. The results obtained show that with a specific thickness, the target material itself can act as filter, which enables generation of X-rays with a limited energy.

  7. PET monitoring of cancer therapy with He-3 and C-12 beams: a study with the GEANT4 toolkit

    CERN Document Server

    Pshenichnov, Igor; Mishustin, Igor; Greiner, Walter

    2007-01-01

    We study the spatial distributions of $\\beta^+$-activity produced by therapeutic beams of $^3$He and $^{12}$C ions in various tissue-like materials. The calculations were performed within a Monte Carlo model for Heavy-Ion Therapy (MCHIT) based on the GEANT4 toolkit. The contributions from $^{10,11}$C, $^{13}$N, $^{14,15}$O, $^{17,18}$F and $^{30}$P positron-emitting nuclei were calculated and compared with experimental data obtained during and after irradiation. Positron emitting nuclei are created by $^{12}$C beam in fragmentation reactions of projectile and target nuclei. This leads to a $\\beta^+$-activity profile characterised by a noticeable peak located close to the Bragg peak in the corresponding depth-dose distribution. On the contrary, as the most of positron-emitting nuclei are produced by $^3$He beam in target fragmentation reactions, the calculated total $\\beta^+$-activity during or soon after the irradiation period is evenly distributed within the projectile range. However, we predict also the pre...

  8. Distributions of positron-emitting nuclei in proton and carbon-ion therapy studied with GEANT4

    CERN Document Server

    Pshenichnov, I; Mishustin, I; Greiner, Walter; Mishustin, Igor; Pshenichnov, Igor

    2006-01-01

    Depth distributions of positron-emitting nuclei in PMMA phantoms are calculated within a Monte Carlo model for Heavy-Ion Therapy (MCHIT) based on the GEANT4 toolkit (version 8.0). The calculated total production rates of $^{11}$C, $^{10}$C and $^{15}$O nuclei are compared with the corresponding results of the FLUKA code and with experimental data. The distributions of e$^+$ annihilation points are obtained by simulating radioactive decay of unstable nuclei and transporting positrons in surrounding medium. A finite spatial resolution of the Positron Emission Tomography (PET) is taken into account in a simplified way. Depth distributions of $\\beta^+$-activity as seen by a PET scanner are calculated and compared to available data for PMMA phantoms. The calculated $\\beta^+$-activity profiles are in good agreement with PET data for proton and $^{12}$C beams at energies suitable for particle therapy. The MCHIT capabilities to calculate $\\beta^+$-activity distributions in tissue-like materials of different chemical ...

  9. Calibration and GEANT4 Simulations of the Phase II Proton Compute Tomography (pCT) Range Stack Detector

    CERN Document Server

    Uzunyan, S A; Boi, S; Coutrakon, G; Dyshkant, A; Francis, K; Hedin, D; Johnson, E; Kalnins, J; Zutshi, V; Ford, R; Rauch, J E; Rubinov, P; Sellberg, G; Wilson, P; Naimuddin, M

    2016-01-01

    Northern Illinois University in collaboration with Fermi National Accelerator Laboratory (FNAL) and Delhi University has been designing and building a proton CT scanner for applications in proton treatment planning. The Phase II proton CT scanner consists of eight planes of tracking detectors with two X and two Y coordinate measurements both before and after the patient. In addition, a range stack detector consisting of a stack of thin scintillator tiles, arranged in twelve eight-tile frames, is used to determine the water equivalent path length (WEPL) of each track through the patient. The X-Y coordinates and WEPL are required input for image reconstruction software to find the relative (proton) stopping powers (RSP) value of each voxel in the patient and generate a corresponding 3D image. In this Note we describe tests conducted in 2015 at the proton beam at the Central DuPage Hospital in Warrenville, IL, focusing on the range stack calibration procedure and comparisons with the GEANT~4 range stack simulati...

  10. Geant4-DNA simulation of DNA damage caused by direct and indirect radiation effects and comparison with biological data.

    Science.gov (United States)

    Villagrasa, Carmen; Meylan, Sylvain; Gonon, Geraldine; Gruel, Gaëtan; Giesen, Ulrich; Bueno, Marta; Rabus, Hans

    2017-09-01

    In this work we present results obtained in the frame of the BioQuaRT project. The objective of the study was the correlation between the number of radiation-induced double strand breaks (DSB) of the DNA molecule and the probability of detecting nuclear foci after targeted microbeam irradiation of cells with protons and alpha particles of different LET. The former were obtained by simulation with new methods integrated into Geant4-DNA that permit calculating the number of DSB in a DNA target model induced by direct and indirect radiation effects. A particular focus was laid in this work on evaluating the influence of different criteria applied to the simulated results for predicting the formation of a direct SSB. Indeed, these criteria have an important impact on the predicted number of DSB per particle track and its dependence with LET. Among the criteria tested in this work, the case that a direct radiation interaction leads to a strand break if the cumulative energy deposited in the backbone part of one nucleotide exceeds a threshold of 17.5 eV leads to the best agreement with the relative LET dependence of number of radiation induced foci. Further calculations and experimental data are nevertheless needed in order to fix the simulation parameters and to help interpreting the biological experimental data observed by immunofluorescence in terms of the DSB complexity.

  11. G4MoNA - A Geant4 Simulation for unbound nuclides detected with MoNA/LISA

    Science.gov (United States)

    Gueye, Paul; Freeman, Jessica; Frank, Nathan; MoNA Collaboration

    2017-01-01

    The MoNA Collaboration has conducted a plethora of experiments to study unbound nuclei near the neutron dripline using the invariant mass technique since 2005. These experiments used a variety of secondary beams from the Coupled Cyclotron Facility of the National Superconducting Cyclotron Laboratory. The experimental setup consists of a large gap superconducting Sweeper magnet for charged fragments separation and the MoNA/LISA neutron detector arrays for neutron detection. Recently, a multi-layered Si/Be segmented target consisting of three 700 mg/cm2 thick 9Be slabs and four 140 μ m Si detectors were added to the setup. This target improves the resolution of the reconstructed decay energy spectra of the unbound nuclides. The Geant4 Monte Carlo simulation toolkit was used to develop a complete realistic model of the setup including a new class to treat the decay of unbound nuclei, the Si/Be segmented target, the MoNA/LISA and the charged fragments detector systems. Comparison between simulated and experimental data will be presented. DoENNSA - DE-NA0000979.

  12. Calculation of lineal energies for water and DNA bases using the Rudd model cross sections integrated within the Geant4-DNA processes

    Science.gov (United States)

    Francis, Z.; El Bitar, Z.; Incerti, S.; Bernal, M. A.; Karamitros, M.; Tran, H. N.

    2017-07-01

    This study presents new parameters for proton ionisation cross sections in guanine, adenine, thymine, and cytosine based upon the semi-empirical Rudd model. The same model was used to find differential electron cross sections considering a speed scaling procedure. To accelerate computation, the total electron cross sections were obtained using the binary-encounter-Bethe approximation instead of the integrated Rudd formula. The cross sections were implemented in the Geant4 simulation toolkit as Geant4-DNA processes, and simulations were carried out measuring protons lineal energies in spherical micrometric volumes filled with water, adenine, thymine, guanine, and cytosine. Large differences were seen in the lineal energies evaluated for the different materials, with the lineal energy measured in guanine being sometimes twice that of water. This suggests that the cross sections developed here should be considered in biological simulations where cellular substructures are modelled, in contrast to the current approach which approximates these volumes as consisting of liquid water.

  13. Monte Carlo simulation of the electron transport through thin slabs: A comparative study of PENELOPE, GEANT3, GEANT4, EGSnrc and MCNPX

    Energy Technology Data Exchange (ETDEWEB)

    Vilches, M. [Servicio de Fisica y Proteccion Radiologica, Hospital Regional Universitario ' Virgen de las Nieves' , Avda. de las Fuerzas Armadas, 2, E-18014 Granada (Spain)]. E-mail: mvilches@ugr.es; Garcia-Pareja, S. [Servicio de Radiofisica Hospitalaria, Hospital Regional Universitario ' Carlos Haya' , Avda. Carlos Haya, s/n, E-29010 Malaga (Spain)]. E-mail: garciapareja@gmail.com; Guerrero, R. [Servicio de Radiofisica, Hospital Universitario ' San Cecilio' , Avda. Dr. Oloriz, 16, E-18012 Granada (Spain)]. E-mail: rafael.guerrero.alcalde.sspa@juntadeandalucia.es; Anguiano, M. [Departamento de Fisica Atomica, Molecular y Nuclear, Universidad de Granada, E-18071 Granada (Spain)]. E-mail: mangui@ugr.es; Lallena, A.M. [Departamento de Fisica Atomica, Molecular y Nuclear, Universidad de Granada, E-18071 Granada (Spain)]. E-mail: lallena@ugr.es

    2007-01-15

    The Monte Carlo simulation of the electron transport through thin slabs is studied with five general purpose codes: PENELOPE, GEANT3, GEANT4, EGSnrc and MCNPX. The different material foils analyzed in the old experiments of Kulchitsky and Latyshev [L.A. Kulchitsky, G.D. Latyshev, Phys. Rev. 61 (1942) 254] and Hanson et al. [A.O. Hanson, L.H. Lanzl, E.M. Lyman, M.B. Scott, Phys. Rev. 84 (1951) 634] are used to perform the comparison between the Monte Carlo codes. Non-negligible differences are observed in the angular distributions of the transmitted electrons obtained with the some of the codes. The experimental data are reasonably well described by EGSnrc, PENELOPE (v.2005) and GEANT4. A general good agreement is found for EGSnrc and PENELOPE (v.2005) in all the cases analyzed.

  14. Development of a Geant4 application to characterise a prototype neutron detector based on three orthogonal (3)He tubes inside an HDPE sphere.

    Science.gov (United States)

    Gracanin, V; Guatelli, S; Prokopovich, D; Rosenfeld, A B; Berry, A

    2017-01-01

    The Bonner Sphere Spectrometer (BSS) system is a well-established technique for neutron dosimetry that involves detection of thermal neutrons within a range of hydrogenous moderators. BSS detectors are often used to perform neutron field surveys in order to determine the ambient dose equivalent H*(10) and estimate health risk to personnel. There is a potential limitation of existing neutron survey techniques, since some detectors do not consider the direction of the neutron field, which can result in overly conservative estimates of dose in neutron fields. This paper shows the development of a Geant4 simulation application to characterise a prototype neutron detector based on three orthogonal (3)He tubes inside a single HDPE sphere built at the Australian Nuclear Science and Technology Organisation (ANSTO). The Geant4 simulation has been validated with respect to experimental measurements performed with an Am-Be source.

  15. Electromagnetism

    CERN Multimedia

    Without the electromagnetic force, you would not be solid. The atoms of your body are held together by electromagnetism: negatively charged electrons are held around the positively charged nucleus. Atoms share electrons to form molecules, so building up the structure of matter. As its name suggests, electromagnetism has a double nature: a moving electric charge creates a magnetic field. This intimate connection between electricity and magnetism was described by James Maxwell in 1864. The electromagnetic force can be both positive and negative : opposite charges attract, whereas like charges repel. Electromagnetic radiation, such as radio, microwaves, light and X-rays, is emitted by charges when they are made to move. For example, an oscillating current in a wire emits radio waves. Text for the interactive: Why do the needles move when you switch on the current ?

  16. Estimating dosimetric quantities of radon progeny using human CT scan data and small tissue volume analysis with Geant4 code system

    Directory of Open Access Journals (Sweden)

    Van Den Akker Evelynn

    2015-01-01

    Full Text Available Estimating the health effects of radon exposure is of great interest because radon is considered the second leading cause of lung cancer after smoking. The dose-response curve is not well understood at low-dose levels where radon exposure is estimated. Therefore, the health mechanisms of radiation due to radon progeny at the cellular and molecular levels are of interest for providing an indication of a possible threshold value above which the exposure may indicate cancer formation. In this paper we present a macroscopic and cellular level numerical analysis of the radon-induced dose estimates based on the Geant4 code system. Macroscopic estimates are assessed based on patient-specific computer tomography scans that provide geometries easily applicable to modeling radiation effects of the radon progeny sources. A small tissue volumes analysis based on the Geant4 code system is developed so as to provide information about the interactions and particle track structures at the microscopic (cellular levels producing the dosimetric effects of radon short-lived progenies. The results presented in this paper also call attention to the capabilities of Geant4 to provide radon-related dosimetric parameters of large and small-scale biological systems.

  17. Observable gravitational and electromagnetic orbits and trajectories in discrete physics

    Energy Technology Data Exchange (ETDEWEB)

    Noyes, H.P.; McGoveran, D.O.

    1988-11-28

    Our discrete and finite version of relativistic quantum mechanics provides an elementary particle physics consistent with the standard model of quarks and leptons. Our recent relativistic calculation of the bound state spectrum of hydrogen has allowed us to make a combinatorial correction to the first order estimate of 1/..cap alpha.. = /Dirac h/c/e/sup 2/ = 137 derived from the combinatorial hierarchy and achieve agreement with experiment up to terms of order ..cap alpha../sup 3/. The same theory requires that to first order /Dirac h/c/Gm/sub p//sup 2/ = 2/sup 127/ + 136 approx. = 1.7 /times/ 10/sup 38/. Using the emission and absorption of spin 1 photons and spin 2 gravitons in this framework, we try to show that we can meet the three additional tests of general relativity---solar red shift, solar bending of light, and precession of the perihelion of Mercury. We predict that a macroscopic electromagnetic orbit would have four times the Sommerfeld precession for basically the same reason that Mercury has six times the Sommerfeld precession. 20 refs.

  18. Utilizing History and Philosophy of Science (HPS) to Teach Physics: The Case of Electromagnetic Theory

    Science.gov (United States)

    Shi, Wei-Zhao

    2015-01-01

    Here the paper provides a historical and philosophical analysis of the development of electromagnetic theory in physics teaching for the benefit of scientific literacy. The analysis is described by the paradigms offered by Kuhn. A number of scientists' work in electromagnetic theory which is embedded in the tension between engaging in…

  19. Space-Time Development of Electromagnetic and Hadronic Showers and Perspectives for Novel Calorimetric Techniques

    CERN Document Server

    Benaglia, Andrea; Lecoq, Paul; Wenzel, Hans; Para, Adam

    2016-01-01

    The performance of hadronic calorimeters will be a key parameter at the next generation of High Energy Physics accelerators. A detector combining fine granularity with excellent timing information would prove beneficial for the reconstruction of both jets and electromagnetic particles with high energy resolution. In this work, the space and time structure of high energy showers is studied by means of a Geant4-based simulation toolkit. In particular, the relevant time scales of the different physics phenomena contributing to the energy loss are investigated. A correlation between the fluctuations of the energy deposition of high energy hadrons and the time development of the showers is observed, which allows for an event-by-event correction to be computed to improve the energy resolution of the calorimeter. These studies are intended to set the basic requirements for the development of a new-concept, total absorption time-imaging calorimeter, which seems now within reach thanks to major technological advanceme...

  20. GEANT4 simulation diagram showing the architecture of the ATLAS test line: the detectors are positioned to receive the beam from the SPS. A muon particle which enters the magnet and crosses all detectors is shown (blue line).

    CERN Multimedia

    2004-01-01

    GEANT4 simulation diagram showing the architecture of the ATLAS test line: the detectors are positioned to receive the beam from the SPS. A muon particle which enters the magnet and crosses all detectors is shown (blue line).

  1. Electromagnetic Waves

    DEFF Research Database (Denmark)

    This book is dedicated to various aspects of electromagnetic wave theory and its applications in science and technology. The covered topics include the fundamental physics of electromagnetic waves, theory of electromagnetic wave propagation and scattering, methods of computational analysis...

  2. Analysis of the track- and dose-averaged LET and LET spectra in proton therapy using the GEANT4 Monte Carlo code

    Energy Technology Data Exchange (ETDEWEB)

    Guan, Fada; Peeler, Christopher; Taleei, Reza; Randeniya, Sharmalee; Ge, Shuaiping; Mirkovic, Dragan; Mohan, Radhe; Titt, Uwe, E-mail: UTitt@mdanderson.org [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, Texas 77030 (United States); Bronk, Lawrence [Department of Experimental Radiation Oncology, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, Texas 77030 (United States); Geng, Changran [Department of Nuclear Science and Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China and Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts 02114 (United States); Grosshans, David [Department of Experimental Radiation Oncology, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, Texas 77030 and Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, Texas 77030 (United States)

    2015-11-15

    Purpose: The motivation of this study was to find and eliminate the cause of errors in dose-averaged linear energy transfer (LET) calculations from therapeutic protons in small targets, such as biological cell layers, calculated using the GEANT 4 Monte Carlo code. Furthermore, the purpose was also to provide a recommendation to select an appropriate LET quantity from GEANT 4 simulations to correlate with biological effectiveness of therapeutic protons. Methods: The authors developed a particle tracking step based strategy to calculate the average LET quantities (track-averaged LET, LET{sub t} and dose-averaged LET, LET{sub d}) using GEANT 4 for different tracking step size limits. A step size limit refers to the maximally allowable tracking step length. The authors investigated how the tracking step size limit influenced the calculated LET{sub t} and LET{sub d} of protons with six different step limits ranging from 1 to 500 μm in a water phantom irradiated by a 79.7-MeV clinical proton beam. In addition, the authors analyzed the detailed stochastic energy deposition information including fluence spectra and dose spectra of the energy-deposition-per-step of protons. As a reference, the authors also calculated the averaged LET and analyzed the LET spectra combining the Monte Carlo method and the deterministic method. Relative biological effectiveness (RBE) calculations were performed to illustrate the impact of different LET calculation methods on the RBE-weighted dose. Results: Simulation results showed that the step limit effect was small for LET{sub t} but significant for LET{sub d}. This resulted from differences in the energy-deposition-per-step between the fluence spectra and dose spectra at different depths in the phantom. Using the Monte Carlo particle tracking method in GEANT 4 can result in incorrect LET{sub d} calculation results in the dose plateau region for small step limits. The erroneous LET{sub d} results can be attributed to the algorithm to

  3. Dose calculations at high altitudes and in deep space with GEANT4 using BIC and JQMD models for nucleus-nucleus reactions

    Energy Technology Data Exchange (ETDEWEB)

    Sihver, L; Mancusi, D [Chalmers University of Technology, Gothenburg, Sweden, (Sweden); Matthiae, D [German Aerospace Center, Cologne (Germany); Koi, T [SLAC, Stanford, CA (United States)], E-mail: sihver@chalmers.se

    2008-10-15

    Radiation exposure of aircrew is more and more recognized as an occupational hazard. The ionizing environment at standard commercial aircraft flight altitudes consists mainly of secondary particles, of which the neutrons give a major contribution to the dose equivalent. Accurate estimations of neutron spectra in the atmosphere are therefore essential for correct calculations of aircrew doses. Energetic solar particle events (SPE) could also lead to significantly increased dose rates, especially at routes close to the North Pole, e.g. for flights between Europe and USA. It is also well known that the radiation environment encountered by personnel aboard low Earth orbit (LEO) spacecraft or aboard a spacecraft traveling outside the Earth's protective magnetosphere is much harsher compared with that within the atmosphere since the personnel are exposed to radiation from both galactic cosmic rays (GCR) and SPE. The relative contribution to the dose from GCR when traveling outside the Earth's magnetosphere, e.g. to the Moon or Mars, is even greater, and reliable and accurate particle and heavy ion transport codes are essential to calculate the radiation risks for both aircrew and personnel on spacecraft. We have therefore performed calculations of neutron distributions in the atmosphere, total dose equivalents, and quality factors at different depths in a water sphere in an imaginary spacecraft during solar minimum in a geosynchronous orbit. The calculations were performed with the GEANT4 Monte Carlo (MC) code using both the binary cascade (BIC) model, which is part of the standard GEANT4 package, and the JQMD model, which is used in the particle and heavy ion transport code PHITS GEANT4.

  4. Geant4 simulation of the Elekta XVI kV CBCT unit for accurate description of potential late toxicity effects of image-guided radiotherapy.

    Science.gov (United States)

    Brochu, F M; Burnet, N G; Jena, R; Plaistow, R; Parker, M A; Thomas, S J

    2014-12-21

    This paper describes the modelisation of the Elekta XVI Cone Beam Computed Tomography (CBCT) machine components with Geant4 and its validation against calibration data taken for two commonly used machine setups. Preliminary dose maps of simulated CBCTs coming from this modelisation work are presented. This study is the first step of a research project, GHOST, aiming to improve the understanding of late toxicity risk in external beam radiotherapy patients by simulating dose depositions integrated from different sources (imaging, treatment beam) over the entire treatment plan. The second cancer risk will then be derived from different models relating irradiation dose and second cancer risk.

  5. The reduction techniques of the particle background for the ATHENA X-IFU instrument at L2 orbit: Geant4 and the CryoAC

    Science.gov (United States)

    Macculi, Claudio, Piro, L.; Gatti, F.; Lotti, S.; Argan, A.; Laurenza, M.; D'Andrea, M.; Torrioli, G.; Biasotti, M.; Corsini, D.; Orlando, A.; Mineo, T.; D'Ai, A.; Molendi, S.; Gastaldello, F.; Bulgarelli, A.; Fioretti, V.; Jacquey, C.; Laurent, P.

    2015-09-01

    We present the particles background reduction techniques aimed at increasing the X-IFU sensitivity which is reduced by primary protons of both solar and Cosmic Rays origin, and secondary electrons. The adopted solutions involve Monte Carlo simulation by both Geant4 toolkit related to the "expected" background at L2 orbit through the payload mass model and the ray tracing technique to evaluate the soft protons components focussed by the optics to the main detector, and the development of an active Cryogenic AntiCoincidence detector and a passive electron shielding to meet the scientific requirements.

  6. Transversality of Electromagnetic Waves in the Calculus-Based Introductory Physics Course

    Science.gov (United States)

    Burko, Lior M.

    2008-01-01

    Introductory calculus-based physics textbooks state that electromagnetic waves are transverse and list many of their properties, but most such textbooks do not bring forth arguments why this is so. Both physical and theoretical arguments are at a level appropriate for students of courses based on such books, and could be readily used by…

  7. Rethinking earthquake-related DC-ULF electromagnetic phenomena: towards a physics-based approach

    Directory of Open Access Journals (Sweden)

    Q. Huang

    2011-11-01

    Full Text Available Numerous electromagnetic changes possibly related with earthquakes have been independently reported and have even been attempted to apply to short-term prediction of earthquakes. However, there are active debates on the above issue because the seismogenic process is rather complicated and the studies have been mainly empirical (i.e. a kind of experience-based approach. Thus, a physics-based study would be helpful for understanding earthquake-related electromagnetic phenomena and strengthening their applications. As a potential physics-based approach, I present an integrated research scheme, taking into account the interaction among observation, methodology, and physical model. For simplicity, this work focuses only on the earthquake-related DC-ULF electromagnetic phenomena. The main approach includes the following key problems: (1 how to perform a reliable and appropriate observation with some clear physical quantities; (2 how to develop a robust methodology to reveal weak earthquake-related electromagnetic signals from noisy background; and (3 how to develop plausible physical models based on theoretical analyses and/or laboratory experiments for the explanation of the earthquake-related electromagnetic signals observed in the field conditions.

  8. Yield estimation of neutron-rich rare isotopes induced by 200 MeV/u {sup 132}Sn beams by using GEANT4

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Jae Won [Department of Physics, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of); Min, Kyung Joo; Ham, Cheolmin [Department of Energy Science, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of); Park, Tae-Sun [Department of Physics, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of); Hong, Seung-Woo, E-mail: swhong@skku.ac.kr [Department of Physics, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of)

    2015-04-15

    A so-called “two-step reaction scheme”, in which neutron-rich rare isotopes obtained from ISOL are post-accelerated and bombarded on a second target, is employed to estimate the production yields of exotic rare isotopes. The production yields of neutron-rich rare isotope fragments induced by 200 MeV/u {sup 132}Sn beams bombarded on a {sup 9}Be target are estimated with Monte Carlo code, GEANT4. To substantiate the use of GEANT4 for this study, benchmark calculations are done for 80 MeV/u {sup 59}Co, 95 MeV/u {sup 72}Zn, 500 MeV/u {sup 92}Mo, and 950 MeV/u {sup 132}Sn beams on the {sup 9}Be target. It is found that {sup 132}Sn beams can produce neutron-rich rare isotopes with 45 ⩽ Z ⩽ 50 more effectively than {sup 238}U beams at the same energy per nucleon.

  9. The Cryogenic AntiCoincidence Detector for the ATHENA X-IFU: Design Aspects by Geant4 Simulation and Preliminary Characterization of the New Single Pixel

    Science.gov (United States)

    Macculi, C.; Argan, A.; D'Andrea, M.; Lotti, S.; Piro, L.; Biasotti, M.; Corsini, D.; Gatti, F.; Orlando, A.; Torrioli, G.

    2016-08-01

    The ATHENA observatory is the second large-class ESA mission, in the context of the Cosmic Vision 2015-2025, scheduled to be launched on 2028 at L2 orbit. One of the two planned focal plane instruments is the X-ray Integral Field Unit (X-IFU), which will be able to perform simultaneous high-grade energy spectroscopy and imaging over the 5 arcmin FoV by means of a kilo-pixel array of transition-edge sensor (TES) microcalorimeters, coupled to a high-quality X-ray optics. The X-IFU sensitivity is degraded by the particle background, induced by primary protons of both solar and cosmic rays' origin and secondary electrons. A Cryogenic AntiCoincidence (CryoAC) TES-based detector, located sensed by Iridium TESs. We currently achieve a TRL = 3-4 at the single-pixel level. We have designed and developed two further prototypes in order to reach TRL = 4. The design of the CryoAC has been also optimized using the Geant4 simulation tool. Here we will describe some results from the Geant4 simulations performed to optimize the design and preliminary test results from the first of the two detectors, 1 cm2 area, made of 65 Ir TESs.

  10. Calculation of extrapolation curves in the 4π(LS)β-γ coincidence technique with the Monte Carlo code Geant4.

    Science.gov (United States)

    Bobin, C; Thiam, C; Bouchard, J

    2016-03-01

    At LNE-LNHB, a liquid scintillation (LS) detection setup designed for Triple to Double Coincidence Ratio (TDCR) measurements is also used in the β-channel of a 4π(LS)β-γ coincidence system. This LS counter based on 3 photomultipliers was first modeled using the Monte Carlo code Geant4 to enable the simulation of optical photons produced by scintillation and Cerenkov effects. This stochastic modeling was especially designed for the calculation of double and triple coincidences between photomultipliers in TDCR measurements. In the present paper, this TDCR-Geant4 model is extended to 4π(LS)β-γ coincidence counting to enable the simulation of the efficiency-extrapolation technique by the addition of a γ-channel. This simulation tool aims at the prediction of systematic biases in activity determination due to eventual non-linearity of efficiency-extrapolation curves. First results are described in the case of the standardization (59)Fe. The variation of the γ-efficiency in the β-channel due to the Cerenkov emission is investigated in the case of the activity measurements of (54)Mn. The problem of the non-linearity between β-efficiencies is featured in the case of the efficiency tracing technique for the activity measurements of (14)C using (60)Co as a tracer.

  11. Improving high school physical science students' understanding of the electromagnetic spectrum: A modified diagram approach

    Science.gov (United States)

    Quebedeaux, James Edward

    The focus of this study was to identify major conceptual difficulties that selected public high school physical science students encounter in understanding a standard electromagnetic spectrum diagram. A research-driven, modified version of that standard diagram was used in this study to determine the value added to student understanding of electromagnetic waves. A content analysis was performed on electromagnetic spectrum diagrams found in US textbooks from the 1950s through the present. A class of public high school physical science students participated in a study consisting of four activities conducted during a three-week unit. Students were given a pre- and post-achievement test and a pre- and post-survey on the regions of the electromagnetic spectrum. At the conclusion of each activity, selected students were interviewed and each co-constructed a concept map with the researcher. The Electromagnetic Spectrum Literacy Rubric (ESLR) was designed and used to assess students' conceptual understanding periodically as they proceeded through the unit study. A mixed methods analysis was performed, employing both qualitative and quantitative data. A paired t-test determined that there was a statistically significant difference (p = 0.014) between the pre- and post-achievement test scores for the class of students participating in the unit study. Effect sizes also determined that students have difficulties with mathematical calculations and wave properties. These topics present conceptual challenges which must be overcome to understand and use an electromagnetic spectrum diagram effectively.

  12. Feasibility of using Geant4 Monte Carlo simulation for IMRT dose calculations for the Novalis Tx with a HD-120 multi-leaf collimator

    Science.gov (United States)

    Jung, Hyunuk; Shin, Jungsuk; Chung, Kwangzoo; Han, Youngyih; Kim, Jinsung; Choi, Doo Ho

    2015-05-01

    The aim of this study was to develop an independent dose verification system by using a Monte Carlo (MC) calculation method for intensity modulated radiation therapy (IMRT) conducted by using a Varian Novalis Tx (Varian Medical Systems, Palo Alto, CA, USA) equipped with a highdefinition multi-leaf collimator (HD-120 MLC). The Geant4 framework was used to implement a dose calculation system that accurately predicted the delivered dose. For this purpose, the Novalis Tx Linac head was modeled according to the specifications acquired from the manufacturer. Subsequently, MC simulations were performed by varying the mean energy, energy spread, and electron spot radius to determine optimum values of irradiation with 6-MV X-ray beams by using the Novalis Tx system. Computed percentage depth dose curves (PDDs) and lateral profiles were compared to the measurements obtained by using an ionization chamber (CC13). To validate the IMRT simulation by using the MC model we developed, we calculated a simple IMRT field and compared the result with the EBT3 film measurements in a water-equivalent solid phantom. Clinical cases, such as prostate cancer treatment plans, were then selected, and MC simulations were performed. The accuracy of the simulation was assessed against the EBT3 film measurements by using a gamma-index criterion. The optimal MC model parameters to specify the beam characteristics were a 6.8-MeV mean energy, a 0.5-MeV energy spread, and a 3-mm electron radius. The accuracy of these parameters was determined by comparison of MC simulations with measurements. The PDDs and the lateral profiles of the MC simulation deviated from the measurements by 1% and 2%, respectively, on average. The computed simple MLC fields agreed with the EBT3 measurements with a 95% passing rate with 3%/3-mm gamma-index criterion. Additionally, in applying our model to clinical IMRT plans, we found that the MC calculations and the EBT3 measurements agreed well with a passing rate of greater

  13. Electromagnetic Waves

    DEFF Research Database (Denmark)

    This book is dedicated to various aspects of electromagnetic wave theory and its applications in science and technology. The covered topics include the fundamental physics of electromagnetic waves, theory of electromagnetic wave propagation and scattering, methods of computational analysis......, material characterization, electromagnetic properties of plasma, analysis and applications of periodic structures and waveguide components, etc....

  14. Evaluation of the fluence to dose conversion coefficients for high energy neutrons using a voxel phantom coupled with the GEANT4 code

    CERN Document Server

    Paganini, S

    2005-01-01

    Crews working on present-day jet aircraft are a large occupationally exposed group with a relatively high average effective dose from Galactic cosmic radiation. Crews of future high-speed commercial flying at higher altitudes would be even more exposed. To help reduce the significant uncertainties in calculations of such exposures, the male adult voxels phantom MAX, developed in the Nuclear Energy Department of Pernambuco Federal University in Brazil, has been coupled with the Monte Carlo simulation code GEANT4. This toolkit, distributed and upgraded from the international scientific community of CERN/Switzerland, simulates thermal to ultrahigh energy neutrons transport and interactions in the matter. The high energy neutrons are pointed as the component that contribute about 70% of the neutron effective dose that represent the 35% to 60% total dose at aircraft altitude. In this research calculations of conversion coefficients from fluence to effective dose are performed for neutrons of energies from 100 MeV ...

  15. Geant4 Monte Carlo simulation of absorbed dose and radiolysis yields enhancement from a gold nanoparticle under MeV proton irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Tran, H.N., E-mail: tranngochoang@tdt.edu.vn [Division of Nuclear Physics, Ton Duc Thang University, Tan Phong Ward, District 7, Ho Chi Minh City (Viet Nam); Faculty of Applied Sciences, Ton Duc Thang University, Tan Phong Ward, District 7, Ho Chi Minh City (Viet Nam); Karamitros, M. [Notre Dame Radiation Laboratory, University of Notre-Dame, IN 46556 (United States); Ivanchenko, V.N. [Geant4 Associates International Ltd, Hebden Bridge (United Kingdom); Guatelli, S.; McKinnon, S. [Centre For Medical Radiation Physics, University of Wollongong (Australia); Illawarra Health and Medical Research, University of Wollongong, NSW (Australia); Murakami, K.; Sasaki, T.; Okada, S. [Computing Research Center, High Energy Accelerator Organization, KEK, Tsukuba City (Japan); Bordage, M.C. [INSERM, UMR 1037, CRCT, F-31000 Toulouse (France); Univ. Toulouse III-Paul Sabatier, UMR 1037, CRCT, F-31000 Toulouse (France); Francis, Z. [Saint Joseph University, Faculty of Sciences, Department of Physics, Beirut (Lebanon); El Bitar, Z. [Institut Pluridisciplinaire Hubert Curien/IN2P3/CNRS, Strasbourg (France); Bernal, M.A. [Instituto de Física Gleb Wataghin, Universidade Estadual de Campinas, SP (Brazil); Shin, J.I. [Division of Heavy Ion Clinical Research, Korea Institute of Radiological and Medical Science, 75, Nowon-ro, Nowon-gu, Seoul (Korea, Republic of); Lee, S.B. [Proton Therapy Center, National Cancer Center, 323, Ilsan-ro, Ilsandong-gu, Goyang-si, Gyeonggi-do (Korea, Republic of); Barberet, Ph. [Univ. Bordeaux, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); Tran, T.T. [VNUHCM-University of Science (Viet Nam); Brown, J.M.C. [School of Mathematics and Physics, Queen’s University Belfast, Belfast, Northern Ireland (United Kingdom); and others

    2016-04-15

    Gold nanoparticles have been reported as a possible radio-sensitizer agent in radiation therapy due to their ability to increase energy deposition and subsequent direct damage to cells and DNA within their local vicinity. Moreover, this increase in energy deposition also results in an increase of the radiochemical yields. In this work we present, for the first time, an in silico investigation, based on the general purpose Monte Carlo simulation toolkit Geant4, into energy deposition and radical species production around a spherical gold nanoparticle 50 nm in diameter via proton irradiation. Simulations were preformed for incident proton energies ranging from 2 to 170 MeV, which are of interest for clinical proton therapy.

  16. GEANT4 Simulation of a Scintillating-Fibre Tracker for the Cosmic-ray Muon Tomography of Legacy Nuclear Waste Containers

    CERN Document Server

    Clarkson, Anthony; Hoek, Matthias; Ireland, David G; Johnstone, Russell; Kaiser, Ralf; Keri, Tibor; Lumsden, Scott; Mahon, David F; McKinnon, Bryan; Murray, Morgan; Nutbeam-Tuffs, Sian; Shearer, Craig; Staines, Cassie; Yang, Guangliang; Zimmerman, Colin

    2013-01-01

    Cosmic-ray muons are highly penetrative charged particles that are observed at sea level with a flux of approximately one per square centimetre per minute. They interact with matter primarily through Coulomb scattering, which is exploited in the field of muon tomography to image shielded objects in a wide range of applications. In this paper, simulation studies are presented that assess the feasibility of a scintillating-fibre tracker system for use in the identification and characterisation of nuclear materials stored within industrial legacy waste containers. A system consisting of a pair of tracking modules above and a pair below the volume to be assayed is simulated within the GEANT4 framework using a range of potential fibre pitches and module separations. Each module comprises two orthogonal planes of fibres that allow the reconstruction of the initial and Coulomb-scattered muon trajectories. A likelihood-based image reconstruction algorithm has been developed that allows the container content to be det...

  17. Simulation, optimization and testing of a novel high spatial resolution X-ray imager based on Zinc Oxide nanowires in Anodic Aluminium Oxide membrane using Geant4

    Science.gov (United States)

    Esfandi, F.; Saramad, S.

    2015-07-01

    In this work, a new generation of scintillator based X-ray imagers based on ZnO nanowires in Anodized Aluminum Oxide (AAO) nanoporous template is characterized. The optical response of ordered ZnO nanowire arrays in porous AAO template under low energy X-ray illumination is simulated by the Geant4 Monte Carlo code and compared with experimental results. The results show that for 10 keV X-ray photons, by considering the light guiding properties of zinc oxide inside the AAO template and suitable selection of detector thickness and pore diameter, the spatial resolution less than one micrometer and the detector detection efficiency of 66% are accessible. This novel nano scintillator detector can have many advantages for medical applications in the future.

  18. Radiation Effects Investigations Based on Atmospheric Radiation Model (ATMORAD) Considering GEANT4 Simulations of Extensive Air Showers and Solar Modulation Potential.

    Science.gov (United States)

    Hubert, Guillaume; Cheminet, Adrien

    2015-07-01

    The natural radiative atmospheric environment is composed of secondary cosmic rays produced when primary cosmic rays hit the atmosphere. Understanding atmospheric radiations and their dynamics is essential for evaluating single event effects, so that radiation risks in aviation and the space environment (space weather) can be assessed. In this article, we present an atmospheric radiation model, named ATMORAD (Atmospheric Radiation), which is based on GEANT4 simulations of extensive air showers according to primary spectra that depend only on the solar modulation potential (force-field approximation). Based on neutron spectrometry, solar modulation potential can be deduced using neutron spectrometer measurements and ATMORAD. Some comparisons between our methodology and standard approaches or measurements are also discussed. This work demonstrates the potential for using simulations of extensive air showers and neutron spectroscopy to monitor solar activity.

  19. Student Understanding of Light as an Electromagnetic Wave: Relating the Formalism to Physical Phenomena.

    Science.gov (United States)

    Ambrose, Bradley S.; Heron, Paula R. L.; Vokos, Stamatis; McDermott, Lillian C.

    1999-01-01

    Some serious difficulties that students have in understanding physical optics may be due in part to a lack of understanding of light as an electromagnetic wave. Describes the development and use of tutorials designed to address students' conceptual difficulties. (Contains over 15 references.) (Author/WRM)

  20. Marching on in anything : Solving electromagnetic field equations with a varying physical parameter

    NARCIS (Netherlands)

    Tijhuis, A.G.; Zwamborn, A.P.M.

    2003-01-01

    In this paper, we consider the determination of electromagnetic flelds for a (large) number of values of a physical parameter. We restrict ourselves to the case where the linear system originates from one or more integral equations. we apply an iterative procedure based on the minimization of an int

  1. Calculation of Positron Distribution in the Presence of a Uniform Magnetic Field for the Improvement of Positron Emission Tomography (PET Imaging Using GEANT4 Toolkit

    Directory of Open Access Journals (Sweden)

    Mohsen Mashayekhi

    2015-05-01

    Full Text Available Introduction Range and diffusion of positron-emitting radiopharmaceuticals are important parameters for image resolution in positron emission tomography (PET. In this study, GEANT4 toolkit was applied to study positron diffusion in soft tissues with and without a magnetic field for six commonly used isotopes in PET imaging including 11C, 13N, 15O, 18F, 68Ga, and 82Rb. Materials and Methods GEANT4 toolkit was used to simulate the transport and interactions of positrons. Calculations were performed for the soft tissue phantom (8 mm ×8 mm × 8 mm. Positrons were emitted isotropically from the center of the phantom. By the application of a magnetic field perpendicular to the path of positrons, lateral scattering of positrons could be prevented due to Lorentz force. When the positron energy was below the cut-off threshold (0.001 MeV, the simulation was terminated. Results The findings showed that the presence of a magnetic field increased the rate of positron annihilation. At magnetic field strengths of 3, 7, and 10 Tesla, 18F with the lowest decay energy showed improvements in the ratio of full width at half maximum (FWHM resolution to the peak of curve by 3.64%, 3.89%, and 5.96%, respectively. In addition, at magnetic field strengths of 3, 7 and 10 Tesla, 82Rb with the highest decay energy showed improvements in resolution by 33%, 85%, and 99%, respectively. Conclusion Application of a magnetic field perpendicular to the positron diffusion plane prevented the scattering of positrons, and consequently, improved the intrinsic spatial resolution of PET imaging, caused by positron range effects.

  2. A polygon-surface reference Korean male phantom (PSRK-Man) and its direct implementation in Geant4 Monte Carlo simulation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chan Hyeong; Jeong, Jong Hwi [Department of Nuclear Engineering, Hanyang University, 17 Haengdang-dong, Seongdong-gu, Seoul 133-791 (Korea, Republic of); Bolch, Wesley E [Department of Nuclear and Radiological Engineering, University of Florida, Gainesville, FL 32611 (United States); Cho, Kun-Woo [Korea Institute of Nuclear Safety, 19 Guseong-dong, Yuseong-gu, Daejeon 305-600 (Korea, Republic of); Hwang, Sung Bae, E-mail: chkim@hanyang.ac.kr [Department of Physical Therapy, Kyungbuk College, Hyucheon 2-dong, Yeongju-si, Gyeongbuk 750-712 (Korea, Republic of)

    2011-05-21

    Even though the hybrid phantom embodies both the anatomic reality of voxel phantoms and the deformability of stylized phantoms, it must be voxelized to be used in a Monte Carlo code for dose calculation or some imaging simulation, which incurs the inherent limitations of voxel phantoms. In the present study, a voxel phantom named VKH-Man (Visible Korean Human-Man), was converted to a polygon-surface phantom (PSRK-Man, Polygon-Surface Reference Korean-Man), which was then adjusted to the Reference Korean data. Subsequently, the PSRK-Man polygon phantom was directly, without any voxelization process, implemented in the Geant4 Monte Carlo code for dose calculations. The calculated dose values and computation time were then compared with those of HDRK-Man (High Definition Reference Korean-Man), a corresponding voxel phantom adjusted to the same Reference Korean data from the same VKH-Man voxel phantom. Our results showed that the calculated dose values of the PSRK-Man surface phantom agreed well with those of the HDRK-Man voxel phantom. The calculation speed for the PSRK-Man polygon phantom though was 70-150 times slower than that of the HDRK-Man voxel phantom; that speed, however, could be acceptable in some applications, in that direct use of the surface phantom PSRK-Man in Geant4 does not require a separate voxelization process. Computing speed can be enhanced, in future, either by optimizing the Monte Carlo transport kernel for the polygon surfaces or by using modern computing technologies such as grid computing and general-purpose computing on graphics processing units programming.

  3. Electromagnetic physical modeling. 11; Denji yudoho no model jikken. 11

    Energy Technology Data Exchange (ETDEWEB)

    Noguchi, K.; Endo, M.; Yoshimori, M.; Ogura, W. [Waseda University, Tokyo (Japan). School of Science and Engineering; Saito, A. [Mitsui Mineral Development Engineering Co. Ltd., Tokyo (Japan)

    1997-05-27

    A model experiment on the well electromagnetic induction method was studied. Experimental apparatus consisted chiefly of A/D boards of 16 bit and 100 kHz. In the transmitting part, the transistor inverter and relay switch controlled by computer with car battery as current source generate rectangular wave current and make it run to the transmitter loop. In the receiving part, after electromotive force induced to the receiver coil was amplified by amplifier, it is A/D converted and recorded by computer. As a result of the experiment, the depth, plane position and shape of the structure could be caught by studying data on the well and earth surface together. Further, it was confirmed that in case the disk tilted, the response regularly changes according to the tilt. Moreover, it was found that even in case the structure is just under the inside of the transmitter loop, the thickness and tilt of the structure are influenced by the positional relation with the receiver loop. 2 refs., 18 figs.

  4. Early Physics at the LHC using the CMS Electromagnetic Calorimeter

    CERN Document Server

    Timlin, Claire

    2008-08-01

    The Compact Muon Solenoid (CMS) is a general purpose detector at the Large Hadron Collider (LHC) at CERN. It has been designed to study proton-proton col- lisions at a centre of mass energy of 14 TeV. CMS has constructed an electromagnetic calorimeter (ECAL) with extremely good energy resolution using scintillating lead tungstate crystals. Radiation studies performed on samples of these crystals are presented in this thesis. Results obtained from operating large parts (supermodules) of the ECAL in a test beam are also presented and compared to simulation. Methods of measuring electron efficiencies with data have been developed, tested and used in the measurement of W and Z boson cross sections in electron decay modes. Samples of ECAL crystals produced by the Shanghai Institute of Ceramics were tested during 2005 for radiation hardness by measuring the drop in light yield caused by irradiation. Results showed crystals were radiation hard enough for use in CMS. The ability to monitor crystals in situ and crysta...

  5. First physics pulses in the Barrel Electromagnetic Calorimeter with cosmics

    CERN Multimedia

    Laurent Serin

    2006-01-01

    The electromagnetic barrel calorimeter has been installed in its final position in October 2005. Since then, the calorimeter is being equipped with front-end electronics. Starting in April 2006, electronics calibration runs are taken a few times per week to debug the electronics and to study the performance in the pit (stability, noise). Today, 10 out of the 32 Front End crates are being read out, amounting to about 35000 channels. cool down, few little typos --> After a 6-week cool down, the barrel cryostat was filled with Liquid Argon in May. The presence of a few shorts (~1MΩ) at the edges of the modules was indicating the possibility of conducting dust having entered into the calorimeter with the flowing liquid. In order to try to improve this situation, the calorimeter was emptied and filled again, but this time by condensating the argon instead of flowing it in liquid phase. The new High Voltage tests are not showing any significant improvement but the situation is statisfactory for ATLAS runn...

  6. Simulation of {sup 60}Co and {sup 137}Csspectra of irradiator Shepherd 81 - 14D do LNMRI/IRD using Geant4; Simulacao dos espectros de {sup 60}Co e {sup 137}Cs do Irradiador Shepherd 81 - 14D do LNMRI/IRD usando o Geant4

    Energy Technology Data Exchange (ETDEWEB)

    Queiroz Filho, P.P.; Cabral, T.S.; Silva, C.N.M. da, E-mail: queiroz@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2016-07-01

    In this work it were simulated, using Geant4, the {sup 60}Co and {sup 137}Cs spectra of the Irradiator Shepherd 81-14D acquired by the National Metrology Laboratory of Ionising Radiation of the Institute of Radiation Protection and Dosimetry ( LNMRI / IRD ), which will be used for calibration in radioprotection. Was checked if photons suffered his first interaction on the source, the structure of the head or the collimators. It was also observed the percentage of occurrence of each type of interaction in such structures. (author)

  7. Electromagnetic Shower Properties in a Lead-Scintillator Sampling Calorimeter

    CERN Document Server

    Kotwal, Ashutosh V

    2013-01-01

    The Collider Detector at Fermilab (CDF) is a general-purpose experimental apparatus with an inner tracking detector for measuring charged particles, surrounded by a calorimeter for measurements of electromagnetic and hadronic showers. We describe a {\\sc geant4} simulation and parameterization of the response of the CDF central electromagnetic calorimeter (CEM) to incident electrons and photons. The detector model consists of a detailed description of the CEM geometry and material in the direction of the incident particle's trajectory, and of the passive material between the tracker and the CEM. We use {\\sc geant4} to calculate the distributions of: the energy that leaks from the back of the CEM, the energy fraction sampled by the scintillators, and the energy dependence of the response. We parameterize these distributions to accurately model electron and photon response and resolution in a custom simulation for the measurement of the $W$ boson mass.

  8. Finite-volume corrections to electromagnetic masses for larger-than-physical electric charges

    Science.gov (United States)

    Matzelle, Matthew E.; Tiburzi, Brian C.

    2017-05-01

    The numerical value of the fine-structure constant generally leads to small isospin-breaking effects due to electromagnetism in QCD. This smallness complicates determining isospin breaking from lattice QCD computations that include electromagnetism. One solution to this problem consists of performing computations using larger-than-physical values of the electric charge, and subsequently extrapolating (or interpolating) to the physical value of the fine-structure constant. Motivated by recent lattice QCD +QED computations of electromagnetic masses employing this setup, we consider finite-volume effects arising from the use of larger-than-physical electric charges. A modified power-counting scheme, which is based on treating the fine-structure constant as larger than its physical value, is explored. Results for perturbative QED corrections, however, are surprising. Within the framework of nonrelativistic QED, multiloop diagrams exhibit a momentum factorization property that produces exact cancellations. We determine that power-law finite-volume effects vanish at the leading two- and three-loop order, as well as the next-to-leading two-loop order. For larger-than-physical charges, we consequently expect no appreciable volume corrections beyond leading-order QED.

  9. Electromagnetic Thermography Nondestructive Evaluation: Physics-based Modeling and Pattern Mining.

    Science.gov (United States)

    Gao, Bin; Woo, Wai Lok; Tian, Gui Yun

    2016-05-09

    Electromagnetic mechanism of Joule heating and thermal conduction on conductive material characterization broadens their scope for implementation in real thermography based Nondestructive testing and evaluation (NDT&E) systems by imparting sensitivity, conformability and allowing fast and imaging detection, which is necessary for efficiency. The issue of automatic material evaluation has not been fully addressed by researchers and it marks a crucial first step to analyzing the structural health of the material, which in turn sheds light on understanding the production of the defects mechanisms. In this study, we bridge the gap between the physics world and mathematical modeling world. We generate physics-mathematical modeling and mining route in the spatial-, time-, frequency-, and sparse-pattern domains. This is a significant step towards realizing the deeper insight in electromagnetic thermography (EMT) and automatic defect identification. This renders the EMT a promising candidate for the highly efficient and yet flexible NDT&E.

  10. Scintillating fiber based in-vivo dose monitoring system to the rectum in proton therapy of prostate cancer: A Geant4 Monte Carlo simulation

    Directory of Open Access Journals (Sweden)

    Biniam Yohannes Tesfamicael

    2014-03-01

    Full Text Available Purpose: To construct a dose monitoring system based on an endorectal balloon coupled to thin scintillating fibers to study the dose to the rectum in proton therapy of prostate cancer.Method: A Geant4 Monte Carlo toolkit was used to simulate the proton therapy of prostate cancer, with an endorectal balloon and a set of scintillating fibers for immobilization and dosimetry measurements, respectively.Results: A linear response of the fibers to the dose delivered was observed to within less than 2%. Results obtained show that fibers close to the prostate recorded higher dose, with the closest fiber recording about one-third of the dose to the target. A 1/r2 (r is defined as center-to-center distance between the prostate and the fibers decrease was observed as one goes toward the frontal and distal regions. A very low dose was recorded by the fibers beneath the balloon which is a clear indication that the overall volume of the rectal wall that is exposed to a higher dose is relatively minimized. Further analysis showed a relatively linear relationship between the dose to the target and the dose to the top fibers (total 17, with a slope of (-0.07 ± 0.07 at large number of events per degree of rotation of the modulator wheel (i.e., dose.Conclusion: Thin (1 mm × 1 mm, long (1 m scintillating fibers were found to be ideal for real time in-vivo dose measurement to the rectum during proton therapy of prostate cancer. The linear response of the fibers to the dose delivered makes them good candidates as dosimeters. With thorough calibration and the ability to define a good correlation between the dose to the target and the dose to the fibers, such dosimeters can be used for real time dose verification to the target.-----------------------------------Cite this article as: Tesfamicael BY, Avery S, Gueye P, Lyons D, Mahesh M. Scintillating fiber based in-vivo dose monitoring system to the rectum in proton therapy of prostate cancer: A Geant4 Monte Carlo

  11. Physics Almost Saved the President! Electromagnetic Induction and the Assassination of James Garfield: A Teaching Opportunity in Introductory Physics

    Science.gov (United States)

    Overduin, James; Molloy, Dana; Selway, Jim

    2014-03-01

    Electromagnetic induction is probably one of the most challenging subjects for students in the introductory physics sequence, especially in algebra-based courses. Yet it is at the heart of many of the devices we rely on today. To help students grasp and retain the concept, we have put together a simple and dramatic classroom demonstration that combines sight and sound with a compelling personal story from U.S. history. Other classroom activities dealing with induction have been discussed in this journal, but we believe that this one will be especially likely to attract and retain student interest, particularly in courses geared toward medical, biological, and other non-physics majors.

  12. University Physics Students' Use of Models in Explanations of Phenomena Involving Interaction between Metals and Electromagnetic Radiation.

    Science.gov (United States)

    Redfors, Andreas; Ryder, Jim

    2001-01-01

    Examines third year university physics students' use of models when explaining familiar phenomena involving interaction between metals and electromagnetic radiation. Concludes that few students use a single model consistently. (Contains 27 references.) (DDR)

  13. Modeling of very low frequency (VLF radio wave signal profile due to solar flares using the GEANT4 Monte Carlo simulation coupled with ionospheric chemistry

    Directory of Open Access Journals (Sweden)

    S. Palit

    2013-09-01

    Full Text Available X-ray photons emitted during solar flares cause ionization in the lower ionosphere (~60 to 100 km in excess of what is expected to occur due to a quiet sun. Very low frequency (VLF radio wave signals reflected from the D-region of the ionosphere are affected by this excess ionization. In this paper, we reproduce the deviation in VLF signal strength during solar flares by numerical modeling. We use GEANT4 Monte Carlo simulation code to compute the rate of ionization due to a M-class flare and a X-class flare. The output of the simulation is then used in a simplified ionospheric chemistry model to calculate the time variation of electron density at different altitudes in the D-region of the ionosphere. The resulting electron density variation profile is then self-consistently used in the LWPC code to obtain the time variation of the change in VLF signal. We did the modeling of the VLF signal along the NWC (Australia to IERC/ICSP (India propagation path and compared the results with observations. The agreement is found to be very satisfactory.

  14. Determination of Tungsten Target Parameters for Transmission X-ray Tube: A Simulation Study Using Geant4

    Directory of Open Access Journals (Sweden)

    Mohammad M. Nasseri

    2016-06-01

    Full Text Available Transmission X-ray tubes based on carbon nanotube have attracted significant attention recently. In most of these tubes, tungsten is used as the target material. In this article, the well-known simulator Geant4 was used to obtain some of the tungsten target parameters. The optimal thickness for maximum production of usable X-rays when the target is exposed to electron beams of different energies was obtained. The linear variation of optimal thickness of the target for different electron energies was also obtained. The data obtained in this study can be used to design X-ray tubes. A beryllium window was considered for the X-ray tube. The X-ray energy spectra at the moment of production and after passing through the target and window for different electron energies in the 30–110 keV range were also obtained. The results obtained show that with a specific thickness, the target material itself can act as filter, which enables generation of X-rays with a limited energy.

  15. Microdosimetry spectra and RBE of H-1, He-4, Li-7 and C-12 nuclei in water studied with Geant4

    CERN Document Server

    Burigo, Lucas; Mishustin, Igor; Bleicher, Marcus

    2013-01-01

    A Geant4-based Monte Carlo model for Heavy-Ion Therapy (MCHIT) is used to study radiation fields of H-1, He-4, Li-7 and C-12 beams with similar ranges (~160-180 mm) in water. Microdosimetry spectra are simulated for wall-less and walled Tissue Equivalent Proportional Counters (TEPCs) placed outside or inside a phantom, as in experiments performed, respectively, at NIRS, Japan and GSI, Germany. The impact of fragmentation reactions on microdosimetry spectra is investigated for He-4, Li-7 and C-12, and contributions from nuclear fragments of different charge are evaluated for various TEPC positions in the phantom. The microdosimetry spectra measured on the beam axis are well described by MCHIT, in particular, in the vicinity of the Bragg peak. However, the simulated spectra for the walled TEPC far from the beam axis are underestimated. Relative Biological Effectiveness (RBE) of the considered beams is estimated using a modified microdosimetric-kinetic model. Calculations show a similar rise of the RBE up to 2.2...

  16. Calculation of direct effects of {sup 60}Co gamma rays on the different DNA structural levels: A simulation study using the Geant4-DNA toolkit

    Energy Technology Data Exchange (ETDEWEB)

    Tajik, Marjan; Rozatian, Amir S.H. [Department of Physics, University of Isfahan, Hezar Jarib Street, Isfahan 81746-73441 (Iran, Islamic Republic of); Semsarha, Farid, E-mail: Semsarha@ibb.ut.ac.ir [Institute of Biochemistry and Biophysics (IBB), University of Tehran, P.O. Box: 13145-1384, Tehran (Iran, Islamic Republic of)

    2015-03-01

    In this study, simple single strand breaks (SSB) and double strand breaks (DSB) due to direct effects of the secondary electron spectrum of {sup 60}Co gamma rays on different organizational levels of a volume model of the B-DNA conformation have been calculated using the Geant4-DNA toolkit. Result of this study for the direct DSB yield shows a good agreement with other theoretical and experimental results obtained by both photons and their secondary electrons; however, in the case of SSB a noticeable difference can be observed. Moreover, regarding the almost constant yields of the direct strand breaks in the different structural levels of the DNA, calculated in this work, and compared with some theoretical studies, it can be deduced that the direct strand breaks yields depend mainly on the primary double helix structure of the DNA and the higher-order structures cannot have a noticeable effect on the direct DNA damage inductions by {sup 60}Co gamma rays. In contrast, a direct dependency between the direct SSB and DSB yields and the volume of the DNA structure has been found. Also, a further study on the histone proteins showed that they can play an important role in the trapping of low energy electrons without any significant effect on the direct DNA strand breaks inductions, at least in the range of energies used in the current study.

  17. Simulating cosmic radiation absorption and secondary particle production of solar panel layers of Low Earth Orbit (LEO) satellite with GEANT4

    Science.gov (United States)

    Yiǧitoǧlu, Merve; Veske, Doǧa; Nilüfer Öztürk, Zeynep; Bilge Demirköz, Melahat

    2016-07-01

    All devices which operate in space are exposed to cosmic rays during their operation. The resulting radiation may cause fatal damages in the solid structure of devices and the amount of absorbed radiation dose and secondary particle production for each component should be calculated carefully before the production. Solar panels are semiconductor solid state devices and are very sensitive to radiation. Even a short term power cut-off may yield a total failure of the satellite. Even little doses of radiation can change the characteristics of solar cells. This deviation can be caused by rarer high energetic particles as well as the total ionizing dose from the abundant low energy particles. In this study, solar panels planned for a specific LEO satellite, IMECE, are analyzed layer by layer. The Space Environment Information System (SPENVIS) database and GEANT4 simulation software are used to simulate the layers of the panels. The results obtained from the simulation will be taken in account to determine the amount of radiation protection and resistance needed for the panels or to revise the design of the panels.

  18. GEANT4 simulation of the neutron background of the C$_6$D$_6$ set-up for capture studies at n_TOF

    CERN Document Server

    Žugec, P.; Bosnar, D.; Altstadt, S.; Andrzejewski, J.; Audouin, L.; Barbagallo, M.; Bécares, V.; Bečvář, F.; Belloni, F.; Berthoumieux, E.; Billowes, J.; Boccone, V.; Brugger, M.; Calviani, M.; Calviño, F.; Cano-Ott, D.; Carrapiço, C.; Cerutti, F.; Chiaveri, E.; Chin, M.; Cortés, G.; Cortés-Giraldo, M.A.; Diakaki, M.; Domingo-Pardo, C.; Dressler, R.; Duran, I.; Dzysiuk, N.; Eleftheriadis, C.; Ferrari, A.; Fraval, K.; Ganesan, S.; García, A.R.; Giubrone, G.; Gómez-Hornillos, M.B.; Gonçalves, I.F.; González-Romero, E.; Griesmayer, E.; Guerrero, C.; Gunsing, F.; Gurusamy, P.; Heinitz, S.; Jenkins, D.G.; Jericha, E.; Kadi, Y.; Käppeler, F.; Karadimos, D.; Kivel, N.; Koehler, P.; Kokkoris, M.; Krtička, M.; Kroll, J.; Langer, C.; Lederer, C.; Leeb, H.; Leong, L.S.; Lo Meo, S.; Losito, R.; Manousos, A.; Marganiec, J.; Martìnez, T.; Massimi, C.; Mastinu, P.F.; Mastromarco, M.; Meaze, M.; Mendoza, E.; Mengoni, A.; Milazzo, P.M.; Mingrone, F.; Mirea, M.; Mondalaers, W.; Paradela, C.; Pavlik, A.; Perkowski, J.; Plompen, A.; Praena, J.; Quesada, J.M.; Rauscher, T.; Reifarth, R.; Riego, A.; Roman, F.; Rubbia, C.; Sarmento, R.; Saxena, A.; Schillebeeckx, P.; Schmidt, S.; Schumann, D.; Tagliente, G.; Tain, J.L.; Tarrío, D.; Tassan-Got, L.; Tsinganis, A.; Valenta, S.; Vannini, G.; Variale, V.; Vaz, P.; Ventura, A.; Versaci, R.; Vermeulen, M.J.; Vlachoudis, V.; Vlastou, R.; Wallner, A.; Ware, T.; Weigand, M.; Weiß, C.; Wright, T.

    2014-01-01

    The neutron sensitivity of the C$_6$D$_6$ detector setup used at n_TOF for capture measurements has been studied by means of detailed GEANT4 simulations. A realistic software replica of the entire n_TOF experimental hall, including the neutron beam line, sample, detector supports and the walls of the experimental area has been implemented in the simulations. The simulations have been analyzed in the same manner as experimental data, in particular by applying the Pulse Height Weighting Technique. The simulations have been validated against a measurement of the neutron background performed with a $^\\mathrm{nat}$C sample, showing an excellent agreement above 1 keV. At lower energies, an additional component in the measured $^\\mathrm{nat}$C yield has been discovered, which prevents the use of $^\\mathrm{nat}$C data for neutron background estimates at neutron energies below a few hundred eV. The origin and time structure of the neutron background have been derived from the simulations. Examples of the neutron backg...

  19. Promoting Conceptual Development in Physics Teacher Education: Cognitive-Historical Reconstruction of Electromagnetic Induction Law

    Science.gov (United States)

    Mäntylä, Terhi

    2013-06-01

    In teaching physics, the history of physics offers fruitful starting points for designing instruction. I introduce here an approach that uses historical cognitive processes to enhance the conceptual development of pre-service physics teachers' knowledge. It applies a method called cognitive-historical approach, introduced to the cognitive sciences by Nersessian (Cognitive Models of Science. University of Minnesota Press, Minneapolis, pp. 3-45, 1992). The approach combines the analyses of actual scientific practices in the history of science with the analytical tools and theories of contemporary cognitive sciences in order to produce knowledge of how conceptual structures are constructed and changed in science. Hence, the cognitive-historical analysis indirectly produces knowledge about the human cognition. Here, a way to use the cognitive-historical approach for didactical purposes is introduced. In this application, the cognitive processes in the history of physics are combined with current physics knowledge in order to create a cognitive-historical reconstruction of a certain quantity or law for the needs of physics teacher education. A principal aim of developing the approach has been that pre-service physics teachers must know how the physical concepts and laws are or can be formed and justified. As a practical example of the developed approach, a cognitive-historical reconstruction of the electromagnetic induction law was produced. For evaluating the uses of the cognitive-historical reconstruction, a teaching sequence for pre-service physics teachers was conducted. The initial and final reports of twenty-four students were analyzed through a qualitative categorization of students' justifications of knowledge. The results show a conceptual development in the students' explanations and justifications of how the electromagnetic induction law can be formed.

  20. Dosimetric impact assessment using a general algorithm in geant4 simulations for a complex-shaped multileaf collimator.

    Science.gov (United States)

    Perales, Á; Cortés-Giraldo, M A; Miras, H; Arráns, R; Gallardo, M I

    2017-04-07

    We have developed an inhouse algorithm for the multileaf collimator (MLC) geometry model construction with an appropriate accuracy for dosimetric tests. Our purpose is to build a complex type of MLC and analyze the influence of the modeling parameters on the dose calculation. Using radiochromic films as detector the following tests were done: (I) Density test field: to compare measured and calculated dose distributions in order to determine the tungsten alloy physical density value. (II) Leaf ends test field: to verify the penumbra shape sensitivity against the discretization level set to simulate the curved leaf ends. (III) MLC-closed field: to obtain the value of the air gap between opposite leaves for a closed configuration which completes the modeling of the MLC leakage radiation. (IV) Picket-fence field: to fit the leaf tilt angle with respect of the divergent ray emerging from the source. For a 18.5g/cm(3) density value we have obtained a maximum, minimum and mean leakage values of 0.43%, 0.36% and 0.38%, similar to the experimental ones. The best discretization level in the leaf ends field shows a 5.51mm FWHM, very close to the measured value (5.49mm). An air gap of 370μm has been used in the simulation for the separation between opposite leaves. Using a 0.44° tilt angle, we found the same pattern as the experimental values. Our code can reproduce complex MLC designs with a submilimetric dosimetric accuracy which implies the necessary background for dose calculation of high clinical interest small fields. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  1. Faraday, Maxwell, and the electromagnetic field how two men revolutionized physics

    CERN Document Server

    Forbes, Nancy

    2014-01-01

    The story of two brilliant nineteenth-century scientists who discovered the electromagnetic field, laying the groundwork for the amazing technological and theoretical breakthroughs of the twentieth century Two of the boldest and most creative scientists of all time were Michael Faraday (1791-1867) and James Clerk Maxwell (1831-1879). This is the story of how these two men - separated in age by forty years - discovered the existence of the electromagnetic field and devised a radically new theory which overturned the strictly mechanical view of the world that had prevailed since Newton's time. The authors, veteran science writers with special expertise in physics and engineering, have created a lively narrative that interweaves rich biographical detail from each man's life with clear explanations of their scientific accomplishments. Faraday was an autodidact, who overcame class prejudice and a lack of mathematical training to become renowned for his acute powers of experimental observation, technological skil...

  2. Physical modeling of small shallow conductive 3-D targets with high-frequency electromagnetics

    Energy Technology Data Exchange (ETDEWEB)

    Birken, R.A.; Poulton, M.; Sterngerg, B.K.

    1996-09-01

    The goal of this study is to show that physical modeling can provide important support for three-dimensional (3D) interpretation of electromagnetic geophysical data for environmental problems. This is specially true when high-frequency electromagnetic methods are used, which are difficult to model with existing 3D forward modeling programs. Existing electromagnetic geophysical systems usually operate in the frequency range of a few hertz to several hundred hertz. For environmental problems, such as characterization of waste sites, systems with higher frequencies are desirable. This is because at lower frequencies, the depth of investigation is too deep for environmental characterizations. This leads to subsurface images, which don`t have enough resolution to map small shallow objects. Electromagnetic 3D modeling programs which solve the full wave equation are still not widely available, even though 3D modeling has improved remarkably during the last few years (Oristaglio and Spies, 1995). Since such a program was not available for this study, we used a specialized 3D program EM1DSH (Zhou, 1989). With this program, we can model layered-earth cases, taking dielectric effects into account over the whole frequency range of interest. Stewart et al. (1994) published ellipticity curves for similar system configurations and frequency ranges that indicate that dielectric effects can not be neglected for model calculations using frequencies above several 100 kHz. EM1DSH can also model thin conductive sheets in a two-layer earth but neglecting dielectric effects. Therefore we are only able to model and compare our field data with 3D forward modeling results for the lower frequencies. One way of bridging the gap between the interpretation needs and limitations of existing 3D forward modeling programs is to conduct physical modeling experiments. 6 refs., 2 figs.

  3. Physical reality of electromagnetic potentials and the classical limit of the Aharonov-Bohm effect

    CERN Document Server

    Tiwari, S C

    2016-01-01

    Recent literature on the Aharonov-Bohm effect has raised fundamental questions on the classical correspondence of this effect and the physical reality of the electromagnetic potentials in quantum mechanics. Reappraisal on Feynman's approach to the classical limit of AB effect is presented. The critique throws light on the significance of quantum interference and quantum phase shifts in any such classical correspondence. Detailed analysis shows that Feynman arguments are untenable on physical grounds and the claim made in the original AB paper that this effect had no classical analog seems valid. The importance of nonintegrable phase factor distinct from the AB phase factor, here termed as Fock-London-Weyl phase factor for the historical reasons, is underlined in connection with the classical aspects/limits. A topological approach incorporating the physical significance of the interaction field momentum is proposed. A new idea emerges from this approach that attributes the origin of the AB effect to the exchan...

  4. SU-E-T-290: Secondary Dose Monitoring Using Scintillating Fibers in Proton Therapy of Prostate Cancer: A Geant4 Monte Carlo Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Tesfamicael, B; Gueye, P; Lyons, D [Hampton University, Hampton, VA (United States); Avery, S [University of Pennsylvania, Sicklerville, NJ (United States); Mahesh, M [Johns Hopkins Univ, Baltimore, MD (United States)

    2014-06-01

    Purpose: To monitor the secondary dose distribution originating from a water phantom during proton therapy of prostate cancer using scintillating fibers. Methods: The Geant4 Monte Carlo toolkit version 9.6.p02 was used to simulate prostate cancer proton therapy based treatments. Two cases were studied. In the first case, 8 × 8 = 64 equally spaced fibers inside three 4 × 4 × 2.54 cmm{sup 3} DuPont™ Delrin blocks were used to monitor the emission of secondary particles in the transverse (left and right) and distal regions relative to the beam direction. In the second case, a scintillating block with a thickness of 2.54 cm and equal vertical and longitudinal dimensions as the water phantom was used. Geometrical cuts were used to extract the energy deposited in each fiber and the scintillating block. Results: The transverse dose distributions from secondary particles in both cases agree within <5% and with a very good symmetry. The energy deposited not only gradually increases as one moves from the peripheral row fibers towards the center of the block (aligned with the center of the prostate) but also decreases as one goes from the frontal to distal region of the block. The ratio of the doses from the prostate to the ones in the middle two rows of fibers showed a linear relationship with a slope (−3.55±2.26) × 10−5 MeV per treatment Gy. The distal detectors recorded a very small energy deposited due to water attenuation. Conclusion: With a good calibration and the ability to define a good correlation between the dose to the external fibers and the prostate, such fibers can be used for real time dose verification to the target.

  5. Technical Note: Implementation of biological washout processes within GATE/GEANT4—A Monte Carlo study in the case of carbon therapy treatments

    Energy Technology Data Exchange (ETDEWEB)

    Martínez-Rovira, I., E-mail: immamartinez@gmail.com; Jouvie, C.; Jan, S. [Service Hospitalier Frédéric Joliot, Commissariat à l’énergie atomique et aux énergies alternatives (CEA/DSV/I2BM/SHFJ), 4 place du général Leclerc, 91401 Orsay Cedex (France)

    2015-04-15

    Purpose: The imaging of positron emitting isotopes produced during patient irradiation is the only in vivo method used for hadrontherapy dose monitoring in clinics nowadays. However, the accuracy of this method is limited by the loss of signal due to the metabolic decay processes (biological washout). In this work, a generic modeling of washout was incorporated into the GATE simulation platform. Additionally, the influence of the washout on the β{sup +} activity distributions in terms of absolute quantification and spatial distribution was studied. Methods: First, the irradiation of a human head phantom with a {sup 12}C beam, so that a homogeneous dose distribution was achieved in the tumor, was simulated. The generated {sup 11}C and {sup 15}O distribution maps were used as β{sup +} sources in a second simulation, where the PET scanner was modeled following a detailed Monte Carlo approach. The activity distributions obtained in the presence and absence of washout processes for several clinical situations were compared. Results: Results show that activity values are highly reduced (by a factor of 2) in the presence of washout. These processes have a significant influence on the shape of the PET distributions. Differences in the distal activity falloff position of 4 mm are observed for a tumor dose deposition of 1 Gy (T{sub ini} = 0 min). However, in the case of high doses (3 Gy), the washout processes do not have a large effect on the position of the distal activity falloff (differences lower than 1 mm). The important role of the tumor washout parameters on the activity quantification was also evaluated. Conclusions: With this implementation, GATE/GEANT 4 is the only open-source code able to simulate the full chain from the hadrontherapy irradiation to the PET dose monitoring including biological effects. Results show the strong impact of the washout processes, indicating that the development of better models and measurement of biological washout data are

  6. GEANT4 simulation of a scintillating-fibre tracker for the cosmic-ray muon tomography of legacy nuclear waste containers

    Science.gov (United States)

    Clarkson, A.; Hamilton, D. J.; Hoek, M.; Ireland, D. G.; Johnstone, J. R.; Kaiser, R.; Keri, T.; Lumsden, S.; Mahon, D. F.; McKinnon, B.; Murray, M.; Nutbeam-Tuffs, S.; Shearer, C.; Staines, C.; Yang, G.; Zimmerman, C.

    2014-05-01

    Cosmic-ray muons are highly penetrative charged particles that are observed at the sea level with a flux of approximately one per square centimetre per minute. They interact with matter primarily through Coulomb scattering, which is exploited in the field of muon tomography to image shielded objects in a wide range of applications. In this paper, simulation studies are presented that assess the feasibility of a scintillating-fibre tracker system for use in the identification and characterisation of nuclear materials stored within industrial legacy waste containers. A system consisting of a pair of tracking modules above and a pair below the volume to be assayed is simulated within the GEANT4 framework using a range of potential fibre pitches and module separations. Each module comprises two orthogonal planes of fibres that allow the reconstruction of the initial and Coulomb-scattered muon trajectories. A likelihood-based image reconstruction algorithm has been developed that allows the container content to be determined with respect to the scattering density λ, a parameter which is related to the atomic number Z of the scattering material. Images reconstructed from this simulation are presented for a range of anticipated scenarios that highlight the expected image resolution and the potential of this system for the identification of high-Z materials within a shielded, concrete-filled container. First results from a constructed prototype system are presented in comparison with those from a detailed simulation. Excellent agreement between experimental data and simulation is observed showing clear discrimination between the different materials assayed throughout.

  7. GEANT4 simulation of a scintillating-fibre tracker for the cosmic-ray muon tomography of legacy nuclear waste containers

    Energy Technology Data Exchange (ETDEWEB)

    Clarkson, A.; Hamilton, D.J.; Hoek, M.; Ireland, D.G. [SUPA, School of Physics and Astronomy, University of Glasgow, Kelvin Building, University Avenue, Glasgow G12 8QQ, Scotland (United Kingdom); Johnstone, J.R. [National Nuclear Laboratory, Central Laboratory, Sellafield, Seascale, Cumbria CA20 1PG, England (United Kingdom); Kaiser, R.; Keri, T.; Lumsden, S. [SUPA, School of Physics and Astronomy, University of Glasgow, Kelvin Building, University Avenue, Glasgow G12 8QQ, Scotland (United Kingdom); Mahon, D.F., E-mail: David.Mahon@Glasgow.ac.uk [SUPA, School of Physics and Astronomy, University of Glasgow, Kelvin Building, University Avenue, Glasgow G12 8QQ, Scotland (United Kingdom); McKinnon, B.; Murray, M.; Nutbeam-Tuffs, S. [SUPA, School of Physics and Astronomy, University of Glasgow, Kelvin Building, University Avenue, Glasgow G12 8QQ, Scotland (United Kingdom); Shearer, C.; Staines, C. [National Nuclear Laboratory, Central Laboratory, Sellafield, Seascale, Cumbria CA20 1PG, England (United Kingdom); Yang, G. [SUPA, School of Physics and Astronomy, University of Glasgow, Kelvin Building, University Avenue, Glasgow G12 8QQ, Scotland (United Kingdom); Zimmerman, C. [National Nuclear Laboratory, Central Laboratory, Sellafield, Seascale, Cumbria CA20 1PG, England (United Kingdom)

    2014-05-11

    Cosmic-ray muons are highly penetrative charged particles that are observed at the sea level with a flux of approximately one per square centimetre per minute. They interact with matter primarily through Coulomb scattering, which is exploited in the field of muon tomography to image shielded objects in a wide range of applications. In this paper, simulation studies are presented that assess the feasibility of a scintillating-fibre tracker system for use in the identification and characterisation of nuclear materials stored within industrial legacy waste containers. A system consisting of a pair of tracking modules above and a pair below the volume to be assayed is simulated within the GEANT4 framework using a range of potential fibre pitches and module separations. Each module comprises two orthogonal planes of fibres that allow the reconstruction of the initial and Coulomb-scattered muon trajectories. A likelihood-based image reconstruction algorithm has been developed that allows the container content to be determined with respect to the scattering density λ, a parameter which is related to the atomic number Z of the scattering material. Images reconstructed from this simulation are presented for a range of anticipated scenarios that highlight the expected image resolution and the potential of this system for the identification of high-Z materials within a shielded, concrete-filled container. First results from a constructed prototype system are presented in comparison with those from a detailed simulation. Excellent agreement between experimental data and simulation is observed showing clear discrimination between the different materials assayed throughout.

  8. Framing the structural role of mathematics in physics lectures: A case study on electromagnetism

    Science.gov (United States)

    Karam, Ricardo

    2014-06-01

    Physics education research has shown that students tend to struggle when trying to use mathematics in a meaningful way in physics (e.g., mathematizing a physical situation or making sense of equations). Concerning the possible reasons for these difficulties, little attention has been paid to the way mathematics is treated in physics instruction. Starting from an overall distinction between a technical approach, which involves an instrumental (tool-like) use of mathematics, and a structural one, focused on reasoning about the physical world mathematically, the goal of this study is to characterize the development of the latter in didactic contexts. For this purpose, a case study was conducted on the electromagnetism course given by a distinguished physics professor. The analysis of selected teaching episodes with the software Videograph led to the identification of a set of categories that describe different strategies used by the professor to emphasize the structural role of mathematics in his lectures. As a consequence of this research, an analytic tool to enable future comparative studies between didactic approaches regarding the way mathematics is treated in physics teaching is provided.

  9. High energy electromagnetic particle transportation on the GPU

    Science.gov (United States)

    Canal, P.; Elvira, D.; Jun, S. Y.; Kowalkowski, J.; Paterno, M.; Apostolakis, J.

    2014-06-01

    We present massively parallel high energy electromagnetic particle transportation through a finely segmented detector on a Graphics Processing Unit (GPU). Simulating events of energetic particle decay in a general-purpose high energy physics (HEP) detector requires intensive computing resources, due to the complexity of the geometry as well as physics processes applied to particles copiously produced by primary collisions and secondary interactions. The recent advent of hardware architectures of many-core or accelerated processors provides the variety of concurrent programming models applicable not only for the high performance parallel computing, but also for the conventional computing intensive application such as the HEP detector simulation. The components of our prototype are a transportation process under a non-uniform magnetic field, geometry navigation with a set of solid shapes and materials, electromagnetic physics processes for electrons and photons, and an interface to a framework that dispatches bundles of tracks in a highly vectorized manner optimizing for spatial locality and throughput. Core algorithms and methods are excerpted from the Geant4 toolkit, and are modified and optimized for the GPU application. Program kernels written in C/C++ are designed to be compatible with CUDA and OpenCL and with the aim to be generic enough for easy porting to future programming models and hardware architectures. To improve throughput by overlapping data transfers with kernel execution, multiple CUDA streams are used. Issues with floating point accuracy, random numbers generation, data structure, kernel divergences and register spills are also considered. Performance evaluation for the relative speedup compared to the corresponding sequential execution on CPU is presented as well.

  10. High energy electromagnetic particle transportation on the GPU

    Energy Technology Data Exchange (ETDEWEB)

    Canal, P. [Fermilab; Elvira, D. [Fermilab; Jun, S. Y. [Fermilab; Kowalkowski, J. [Fermilab; Paterno, M. [Fermilab; Apostolakis, J. [CERN

    2014-01-01

    We present massively parallel high energy electromagnetic particle transportation through a finely segmented detector on a Graphics Processing Unit (GPU). Simulating events of energetic particle decay in a general-purpose high energy physics (HEP) detector requires intensive computing resources, due to the complexity of the geometry as well as physics processes applied to particles copiously produced by primary collisions and secondary interactions. The recent advent of hardware architectures of many-core or accelerated processors provides the variety of concurrent programming models applicable not only for the high performance parallel computing, but also for the conventional computing intensive application such as the HEP detector simulation. The components of our prototype are a transportation process under a non-uniform magnetic field, geometry navigation with a set of solid shapes and materials, electromagnetic physics processes for electrons and photons, and an interface to a framework that dispatches bundles of tracks in a highly vectorized manner optimizing for spatial locality and throughput. Core algorithms and methods are excerpted from the Geant4 toolkit, and are modified and optimized for the GPU application. Program kernels written in C/C++ are designed to be compatible with CUDA and OpenCL and with the aim to be generic enough for easy porting to future programming models and hardware architectures. To improve throughput by overlapping data transfers with kernel execution, multiple CUDA streams are used. Issues with floating point accuracy, random numbers generation, data structure, kernel divergences and register spills are also considered. Performance evaluation for the relative speedup compared to the corresponding sequential execution on CPU is presented as well.

  11. Application of the parametric formulae for electromagnetic showers in unconverted γ/π0 discrimination

    Institute of Scientific and Technical Information of China (English)

    TAO Jun-Quan; WANG Jian; WANG Xian-You; WANG Zheng; XIAO Hong; XU Ming; ZANG Jing-Jing; ZHANG Zhen-Xia; CHEN Guo-Ming; YANG Min; BIAN Jian-Guo; LI Zu-Hao; LIANG Song; MENG Xiang-Wei; TANG Zhi-Cheng; WANG Jian

    2011-01-01

    In the LHC experiment,the neutral pions produced during jet fragmentation are the background sources for all physics channels with high-energy photons in their final state.In this paper,the application of the three-dimensional parametric formula for electromagnetic(EM)showers,which we developed in the Alpha Magnetic Spectrometer Ⅱ experiment,is presented to distinguish the unconverted photons from the neutral pions.With the constructed electromagnetic calorimeter(ECAL)in a GEANT4 simulation,the parametric formulae were validated and the unconverted γ/π0 discrimination was performed with the Toolkit for Multivariate Data Analysis(TMVA)package in ROOT for different transverse energies ranging from 15 GeV to75 GeV,which is the most sensitive region for light Higgs(with mass~120 GeV)searches with the channel H→γγ.With this discrimination method and the selected transverse energy region,we can reject π0 with the efficiency from~40%(65-75 GeV)to~90%(15-25 GeV)when keeping 90% γefficiency.

  12. Electromagnetic material changes for remote detection and monitoring: a feasibility study: Progress report

    Energy Technology Data Exchange (ETDEWEB)

    McCloy, John S.; Jordan, David V.; Kelly, James F.; McMakin, Douglas L.; Johnson, Bradley R.; Campbell, Luke W.

    2009-09-01

    A new concept for radiation detection is proposed, allowing a decoupling of the sensing medium and the readout. An electromagnetic material, such as a magnetic ceramic ferrite, is placed near a source to be tracked such as a shipping container. The electromagnetic material changes its properties, in this case its magnetic permeability, as a function of radiation. This change is evident as a change in reflection frequency and magnitude when probed using a microwave/millimeter-wave source. This brief report discusses modeling of radiation interaction of various candidate materials using a radiation detector modeling code Geant4, system design considerations for the remote readout, and some theory of the material interaction physics. The theory of radiation change in doped magnetic insulator ferrites such as yttrium iron garnet (YIG) seems well founded based on literature documentation of the photomagnetic effect. The literature also suggests sensitivity of permittivity to neutrons in some ferroelectrics. Research to date indicates that experimental demonstration of these effects in the context of radiation detection is warranted.

  13. A physical pattern recognition approach for 2D electromagnetic induction studies

    Directory of Open Access Journals (Sweden)

    D. Patella

    2000-06-01

    Full Text Available We present a new tomographic procedure for the analysis of natural source electromagnetic (EM induction field data collected over any complex 2D buried structure beneath a flat air-earth boundary. The tomography is developed in a pure physical context and the primary goal is the depiction of the space distribution of two occurrence probability functions for the induced electrical charge accumulations on resistivity discontinuities and current channelling inside conductive bodies, respectively. The procedure to obtain tomographic image consists of a scanning operation governed analytically by a set of multiple interference cross-correlations between the observed EM components and the corresponding synthetic components of a pair of elementary charge and dipole. To show the potentiality of the proposed physical tomography, we discuss the results from three 2D synthetic examples.

  14. A portable secondary dose monitoring system using scintillating fibers for proton therapy of prostate cancer: A Geant4 Monte Carlo simulation study

    Directory of Open Access Journals (Sweden)

    Biniam Tesfamicael

    2016-03-01

    Full Text Available Purpose: The main purpose of this study was to monitor the secondary dose distribution originating from a water phantom during proton therapy of prostate cancer using scintillating fibers.Methods: The Geant4 Monte Carlo toolkit version 9.6.p02 was used to simulate a proton therapy of prostate cancer. Two cases were studied. In the first case, 8 × 8 = 64 equally spaced fibers inside three 4 × 4 × 2.54 cm3 Delrin® blocks were used to monitor the emission of secondary particles in the transverse (left and right and distal regions relative to the beam direction. In the second case, a scintillating block with a thickness of 2.54 cm and equal vertical and longitudinal dimensions as the water phantom was used. Geometrical cuts were implemented to extract the energy deposited in each fiber and inside the scintillating block.Results: The transverse dose distributions from the detected secondary particles in both cases are symmetric and agree to within <3.6%. The energy deposited gradually increases as one moves from the peripheral row of fibers towards the center of the block (aligned with the center of the prostate by a factor of approximately 5. The energy deposited was also observed to decrease as one goes from the frontal to distal region of the block. The ratio of the energy deposited in the prostate to the energy deposited in the middle two rows of fibers showed a linear relationship with a slope of (-3.55±2.26 × 10-5 MeV per treatment Gy delivered. The distal detectors recorded a negligible amount of energy deposited due to higher attenuation of the secondary particles by the water in that direction.Conclusion: With a good calibration and with the ability to define a good correlation between the radiation flux recorded by the external fibers and the dose delivered to the prostate, such fibers can be used for real time dose verification to the target. The system was also observed to respond to the series of Bragg Peaks used to generate the

  15. The investigation of prostatic calcifications using μ-PIXE analysis and their dosimetric effect in low dose rate brachytherapy treatments using Geant4

    Science.gov (United States)

    Pope, D. J.; Cutajar, D. L.; George, S. P.; Guatelli, S.; Bucci, J. A.; Enari, K. E.; Miller, S.; Siegele, R.; Rosenfeld, A. B.

    2015-06-01

    Low dose rate brachytherapy is a widely used modality for the treatment of prostate cancer. Most clinical treatment planning systems currently in use approximate all tissue to water, neglecting the existence of inhomogeneities, such as calcifications. The presence of prostatic calcifications may perturb the dose due to the higher photoelectric effect cross section in comparison to water. This study quantitatively evaluates the effect of prostatic calcifications on the dosimetric outcome of brachytherapy treatments by means of Monte Carlo simulations and its potential clinical consequences. Four pathological calcification samples were characterised with micro-particle induced x-ray emission (μ-PIXE) to determine their heavy elemental composition. Calcium, phosphorus and zinc were found to be the predominant heavy elements in the calcification composition. Four clinical patient brachytherapy treatments were modelled using Geant4 based Monte Carlo simulations, in terms of the distribution of brachytherapy seeds and calcifications in the prostate. Dose reductions were observed to be up to 30% locally to the calcification boundary, calcification size dependent. Single large calcifications and closely placed calculi caused local dose reductions of between 30-60%. Individual calculi smaller than 0.5 mm in diameter showed minimal dosimetric impact, however, the effects of small or diffuse calcifications within the prostatic tissue could not be determined using the methods employed in the study. The simulation study showed a varying reduction on common dosimetric parameters. D90 showed a reduction of 2-5%, regardless of calcification surface area and volume. The parameters V100, V150 and V200 were also reduced by as much as 3% and on average by 1%. These reductions were also found to relate to the surface area and volume of calcifications, which may have a significant dosimetric impact on brachytherapy treatment, however, such impacts depend strongly on specific factors

  16. Lateral variations of radiobiological properties of therapeutic fields of 1H, 4He, 12C and 16O ions studied with Geant4 and microdosimetric kinetic model

    Science.gov (United States)

    Dewey, Sophie; Burigo, Lucas; Pshenichnov, Igor; Mishustin, Igor; Bleicher, Marcus

    2017-07-01

    As known, in cancer therapy with ion beams the relative biological effectiveness (RBE) of ions changes in the course of their propagation in tissues. Such changes are caused not only by increasing the linear energy transfer (LET) of beam particles with the penetration depth towards the Bragg peak, but also by nuclear reactions induced by beam nuclei leading to the production of various secondary particles. Although the changes of RBE along the beam axis have been studied quite well, much less attention has been paid to the evolution of RBE in the transverse direction, perpendicular to the beam axis. In order to fill this gap, we simulated radiation fields of 1H, 4He, 12C and 16O nuclei of 20 mm in diameter by means of a Geant4-based Monte Carlo model for heavy-ion therapy connected with the modified microdosimetric kinetic model to describe the response of normal ((α/β)_x-rays=3.8 Gy) and early-responding ((α/β)_x-rays=10 Gy) tissues. Depth and radial distributions of saturation-corrected dose-mean lineal energy, RBE and RBE-weighted dose are investigated for passive beam shaping and active beam scanning. The field of 4He has a small lateral spread as compared with 1H field, and it is characterised by a modest lateral variation of RBE suggesting the use of fixed RBE values across the field transverse cross section at each depth. Reduced uncertainties of RBE on the boundary of a 4He treatment field can be advantageous in a specific case of an organ at risk located in lateral proximity to the target volume. It is found that the lateral distributions of RBE calculated for 12C and 16O fields demonstrate fast variations in the radial direction due to changes of dose and composition of secondary fragments in the field penumbra. Nevertheless, the radiation fields of all four projectiles at radii larger than 20 mm can be characterized by a common RBE value defined by tissue radiosensitivity. These findings can help, in particular, in accessing the transverse

  17. High-energy electromagnetic cascades in extragalactic space: Physics and features

    Science.gov (United States)

    Berezinsky, V.; Kalashev, O.

    2016-07-01

    Using the analytic modeling of the electromagnetic cascades compared with more precise numerical simulations, we describe the physical properties of electromagnetic cascades developing in the universe on cosmic microwave background and extragalactic background light radiations. A cascade is initiated by very-high-energy photon or electron, and the remnant photons at large distance have two-component energy spectrum, ∝E-2 (∝E-1.9 in numerical simulations) produced at the cascade multiplication stage and ∝E-3 /2 from Inverse Compton electron cooling at low energies. The most noticeable property of the cascade spectrum in analytic modeling is "strong universality," which includes the standard energy spectrum and the energy density of the cascade ωcas as its only numerical parameter. Using numerical simulations of the cascade spectrum and comparing it with recent Fermi LAT spectrum, we obtained the upper limit on ωcas stronger than in previous works. The new feature of the analysis is the "Emax rule." We investigate the dependence of ωcas on the distribution of sources, distinguishing two cases of universality: the strong and weak ones.

  18. The endpoint formalism for the calculation of electromagnetic radiation and its applications in astroparticle physics

    CERN Document Server

    Huege, Tim; Falcke, Heino; Ludwig, Marianne

    2011-01-01

    We present the "endpoint" formalism for the calculation of electromagnetic radiation and illustrate its applications in astroparticle physics. We use the formalism to explain why the coherent radiation from the Askaryan effect is not in general Cherenkov radiation, as the emission directly results from the time-variation of the net charge in the particle shower. Secondly, we illustrate how the formalism has been applied in the air shower radio emission code REAS3 to unify the microscopic and macroscopic views of radio emission from extensive air showers. Indeed, the formalism is completely universal and particularly well-suited for implementation in Monte Carlo codes in the time- and frequency-domains. It easily reproduces well-known "classical mechanisms" such as synchrotron radiation, Vavilov-Cherenkov radiation and transition radiation in the adequate limits, but has the advantage that it continues to work in realistic, complex situations, where the "classical mechanisms" tend to no longer apply and adheri...

  19. Exploring viscous damping in undergraduate Physics laboratory using electromagnetically coupled oscillators

    CERN Document Server

    Jayaprasad, N; Bhalerao, M; Sengupta, Anand S; Majumder, Barun

    2013-01-01

    We design a low-cost, electromagnetically coupled, simple harmonic oscillator and demonstrate free, damped and forced oscillations in an under-graduate (UG) Physics laboratory. It consists of a spring-magnet system that can oscillate inside a cylinder around which copper coils are wound. Such demonstrations can compliment the traditional way in which a Waves & Oscillations course is taught and offers a richer pedagogical experience for students. We also show that with minimal modifications, it can be used to probe the magnitude of viscous damping forces in liquids by analyzing the oscillations of an immersed magnet. Finally, we propose some student activities to explore non-linear damping effects and their characterization using this apparatus.

  20. Engineering Mathematics I : Electromagnetics, Fluid Mechanics, Material Physics and Financial Engineering

    CERN Document Server

    Rančić, Milica

    2016-01-01

    This book highlights the latest advances in engineering mathematics with a main focus on the mathematical models, structures, concepts, problems and computational methods and algorithms most relevant for applications in modern technologies and engineering. In particular, it features mathematical methods and models of applied analysis, probability theory, differential equations, tensor analysis and computational modelling used in applications to important problems concerning electromagnetics, antenna technologies, fluid dynamics, material and continuum physics and financial engineering. The individual chapters cover both theory and applications, and include a wealth of figures, schemes, algorithms, tables and results of data analysis and simulation. Presenting new methods and results, reviews of cutting-edge research, and open problems for future research, they equip readers to develop new mathematical methods and concepts of their own, and to further compare and analyse the methods and results discussed. The ...

  1. Analogical scaffolding and the learning of abstract ideas in physics: An example from electromagnetic waves

    Directory of Open Access Journals (Sweden)

    Noah D. Finkelstein

    2007-06-01

    Full Text Available This paper describes a model of analogy, analogical scaffolding, which explains present and prior results of student learning with analogies. We build on prior models of representation, blending, and layering of ideas. Extending this model’s explanatory power, we propose ways in which the model can be applied to design a curriculum directed at teaching abstract ideas in physics using multiple, layered analogies. We report on a recent empirical study that motivates this model. Students taught about electromagnetic waves in a curriculum that builds on the model of analogical scaffolding posted substantially greater gains pre- to postinstruction than students taught using a more traditional (non-analogy-based tutorial (21% vs 7%.

  2. Review of the Elementary Particles Physics in the External Electromagnetic Fields Studies at KEK

    Science.gov (United States)

    Konstantinova, O. Tanaka

    2017-03-01

    High Energy Accelerator Research Organization (KEK [1]) is a world class accelerator-based research laboratory. The field of its scientific interests spreads widely from the study of fundamental properties of matter, particle physics, nuclear physics to materials science, life science, technical researches, and industrial applications. Research outcomes from the laboratory achieved making use of high-energy particle beams and synchrotron radiation. Two synchrotron facilities of KEK, the Photon Factory (PF) ring and the Photon Factory Advanced Ring (PF-AR) are the second biggest synchrotron light source in Japan. A very wide range of the radiated light, from visible light to X-ray, is provided for a variety of materials science, biology, and life science [2]. KEK strives to work closely with national and international research institutions, promoting collaborative research activities. Advanced research and facilities provision are key factors to be at the frontier of the accelerator science. In this review I am going to discuss KEK overall accelerator-based science, and to consider light sources research and development. The state of arts of the current projects with respect to the elementary particles physics in the external electromagnetic fields is also stressed here.

  3. Review of the Elementary Particles Physics in the External Electromagnetic Fields Studies at KEK

    Science.gov (United States)

    (Konstantinova), O. Tanaka

    2017-03-01

    High Energy Accelerator Research Organization (KEK [1]) is a world class accelerator-based research laboratory. The field of its scientific interests spreads widely from the study of fundamental properties of matter, particle physics, nuclear physics to materials science, life science, technical researches, and industrial applications. Research outcomes from the laboratory achieved making use of high-energy particle beams and synchrotron radiation. Two synchrotron facilities of KEK, the Photon Factory (PF) ring and the Photon Factory Advanced Ring (PF-AR) are the second biggest synchrotron light source in Japan. A very wide range of the radiated light, from visible light to X-ray, is provided for a variety of materials science, biology, and life science [2]. KEK strives to work closely with national and international research institutions, promoting collaborative research activities. Advanced research and facilities provision are key factors to be at the frontier of the accelerator science. In this review I am going to discuss KEK overall accelerator-based science, and to consider light sources research and development. The state of arts of the current projects with respect to the elementary particles physics in the external electromagnetic fields is also stressed here.

  4. Non-specific physical symptoms in relation to actual and perceived exposure to electromagnetic fields (EMF) : A multidisciplinary approach

    NARCIS (Netherlands)

    Baliatsas, C.

    2015-01-01

    The association between non-specific physical symptoms (NSPS) such as headache, fatigue, nausea and sleep problems and exposure to electromagnetic fields (EMF) in the general population has been a subject of ongoing scientific debate and public concern. A limited number of epidemiological studies ha

  5. Physical and Electromagnetic Properties of Customized Coatings for SNS Injection Ceramic Chambers and Extraction Ferrite Kickers

    CERN Document Server

    Hseuh Hsiao Chaun; He, Ping; Henderson, Stuart; Pai, Chien; Raparia, Deepak; Todd, Robert J; Wang, Lanfa; Wei, Jie; Weiss, Daniel; Yung Lee, Yong

    2005-01-01

    The inner surfaces of the 248 m SNS accumulator ring vacuum chambers are coated with ~100 nm of titanium nitride (TiN) to reduce the secondary electron yield (SEY) of the chamber walls. All the ring inner surfaces are made of stainless or inconel, except those of the injection and extraction kickers. Ceramic vacuum chambers are used for the 8 injection kickers to avoid shielding of a fast-changing kicker field and to reduce eddy current heating. The internal diameter was coated with Cu to reduce the beam coupling impedance and provide passage for beam image current, and a TiN overlayer to reduce SEY. The ferrite surfaces of the 14 extraction kicker modules were coated with TiN to reduce SEY. Customized masks were used to produce coating strips of 1 cm x 5 cm with 1 to 1.5 mm separation among the strips. The masks maximized the coated area to more than 80%, while minimizing the eddy current effect to the kicker rise time. The coating method, as well as the physical and electromagnetic properties of the coating...

  6. An analysis of how electromagnetic induction and Faraday's law are presented in general physics textbooks, focusing on learning difficulties

    Science.gov (United States)

    Guisasola, Jenaro; Zuza, Kristina; Almudi, José-Manuel

    2013-07-01

    Textbooks are a very important tool in the teaching-learning process and influence important aspects of the process. This paper presents an analysis of the chapter on electromagnetic induction and Faraday's law in 19 textbooks on general physics for first-year university courses for scientists and engineers. This analysis was based on criteria formulated from the theoretical framework of electromagnetic induction in classical physics and students' learning difficulties concerning these concepts. The aim of the work presented here is not to compare a textbook against the ideal book, but rather to try and find a series of explanations, examples, questions, etc that provide evidence on how the topic is presented in relation to the criteria above. It concludes that despite many aspects being covered properly, there are others that deserve greater attention.

  7. Asymptotics of physical solutions to the Lorentz-Dirac equation for planar motion in constant electromagnetic fields

    Science.gov (United States)

    Kazinski, P. O.; Shipulya, M. A.

    2011-06-01

    We present a study of planar physical solutions to the Lorentz-Dirac equation in a constant electromagnetic field. In this case, we reduced the Lorentz-Dirac equation to one second-order differential equation. We obtained the asymptotics of physical solutions to this equation at large proper times. It turns out that, in a crossed constant uniform electromagnetic field with vanishing invariants, a charged particle enters a universal regime at large times. We found that the ratios of momentum components that tend to constants are determined only by the external field. This effect is essentially due to a radiation reaction. There is no such effect for the Lorentz equation in this field.

  8. Asymptotics of physical solutions to the Lorentz-Dirac equation for a planar motion in constant electromagnetic fields

    CERN Document Server

    Kazinski, P O

    2010-01-01

    We present a study of planar physical solutions to the Lorentz-Dirac equation in a constant electromagnetic field. In this case, we reduced the Lorentz-Dirac equation to the one second order differential equation. We found the asymptotics of physical solutions to this equation at large proper times. It turns out that, in the crossed constant uniform electromagnetic field with vanishing invariants, a charged particle goes to a universal regime at large times. We found the ratio of momentum components which tends to a constant determined only by the external field. This effect is essentially due to a radiation reaction. There is no such an effect for the Lorentz equation in this field.

  9. Optimising and extending the geometrical modeller of a physics simulation framework

    CERN Document Server

    Urban, P

    1998-01-01

    The design of highly complex particle detectors used in High Energy Physics involves both CAD systems and physics simulation packages like Geant4. Geant4 is able to exchange detector geometries with CAD systems, conforming to the Standard for the Exchange of Product Model Data (STEP); Boundary Representation (B-Rep) models are transferred. Particle tracking is performed in these models, requiring efficient and accurate intersection computations from the geometrical modeller. The results of extending and optimising the modeller of Geant4 form the contents of this thesis. Swept surfaces: surfaces of linear extrusion and surfaces of revolution have been implemented. The problem of classifying points on surfaces bounded by curves as being inside or outside has been solved. These tasks necessitated the extension and optimisation of code related to curves and lead to a re-design of this code. Emphasis was put on efficiency and on dealing with numerical errors. The results will be integrated into the upcoming beta t...

  10. Topological Foundations of Electromagnetism

    CERN Document Server

    Barrett, Terrence W

    2008-01-01

    Topological Foundations of Electromagnetism seeks a fundamental understanding of the dynamics of electromagnetism; and marshals the evidence that in certain precisely defined topological conditions, electromagnetic theory (Maxwell's theory) must be extended or generalized in order to provide an explanation and understanding of, until now, unusual electromagnetic phenomena. Key to this generalization is an understanding of the circumstances under which the so-called A potential fields have physical effects. Basic to the approach taken is that the topological composition of electromagnetic field

  11. A comparison of MCNP6-1.0 and GEANT 4-10.1 when evaluating the neutron output of a complex real world nuclear environment: The thermal neutron facility at the Tri Universities Meson facility

    Energy Technology Data Exchange (ETDEWEB)

    Monk, S.D., E-mail: s.monk@lancaster.ac.uk [Department of Engineering, Lancaster University, Lancaster LA1 4YW (United Kingdom); Shippen, B.A. [Department of Engineering, Lancaster University, Lancaster LA1 4YW (United Kingdom); Colling, B.R. [Department of Engineering, Lancaster University, Lancaster LA1 4YW (United Kingdom); Culham Centre for Fusion Energy, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Cheneler, D.; Al Hamrashdi, H.; Alton, T. [Department of Engineering, Lancaster University, Lancaster LA1 4YW (United Kingdom)

    2017-05-15

    Highlights: • Comparison of the use of MCNP6 and GEANT4 Monte Carlo software when large distances and thicknesses are considered. • The Thermal Neutron Facility (TNF) at TRIUMF used as an example real life example location. • The effects of water, aluminium, iron and lead considered over various thicknesses up to 3 m. - Abstract: A comparison of the Monte Carlo based simulation codes MCNP6-1.0 and GEANT4-10.1 as used for modelling large scale structures is presented here. The high-energy neutron field at the Tri Universities Meson Facility (TRIUMF) in Vancouver, British Columbia is the structure modelled in this work. Work with the emphasis on the modelling of the facility and comparing with experimental results has been published previously, whereas this work is focussed on comparing the performance of the codes over relatively high depths of material rather than the accuracy of the results themselves in comparison to experimental data. Comparisons of three different locations within the neutron facility are modelled and presented using both codes as well as analysis of the transport of typical neutrons fields through large blocks of iron, water, lead and aluminium in order to determine where any deviations are likely to have occurred. Results indicate that over short distances, results from the two codes are in broad agreement – although over greater distances and within more complex geometries, deviation increases dramatically. The conclusions reached are that it is likely the deviations between the codes is caused by both the compounding effect of slight differences between the cross section files used by the two codes to determine the neutron transport through iron, and differences in the processes used by both codes.

  12. Three-dimensional direct numerical simulation of electromagnetically driven multiscale shallow layer flows: Numerical modeling and physical properties

    Science.gov (United States)

    Lardeau, Sylvain; Ferrari, Simone; Rossi, Lionel

    2008-12-01

    Three-dimensional (3D) direct numerical simulations of a flow driven by multiscale electromagnetic forcing are performed in order to reproduce with maximum accuracy the quasi-two-dimensional (2D) flow generated by the same multiscale forcing in the laboratory. The method presented is based on a 3D description of the flow and the electromagnetic forcing. Very good agreements between our simulations and the experiments are found both on velocity and acceleration field, this last comparison being, to our knowledge, done for the first time. Such agreement requires that both experiments and simulations are carefully performed and, more importantly, that the underlying simplification to model the experiments and the multiscale electromagnetic forcing do not introduce significant errors. The results presented in this paper differ significantly from previous 2D direct numerical simulation in which a classical linear Rayleigh friction modeling term was used to mimic the effect of the wall-normal friction. Indeed, purely 2D simulations are found to underestimate the Reynolds number and, due to the dominance of nonhomogeneous bottom friction, lead to the wrong physical mechanism. For the range of conditions presented in this paper, the Reynolds number, defined by the ratio between acceleration and viscous terms, remains the order of unity, and the Hartmann number, defined by the ratio between electromagnetic force terms and viscous terms, is about 2. The main conclusion is that 3D simulations are required to model the (3D) electromagnetic forces and the wall-normal shear. Indeed, even if the flow is quasi-2D in terms of energy, a full 3D approach is required to simulate these shallow layer flows driven by multiscale electromagnetic forcing. In the range of forcing intensity investigated in this paper, these multiscale flows remain quasi-2D, with negligible energy in the wall-normal velocity component. It is also shown that the driving terms are the electromagnetic forcing and

  13. On the Physics of Frequency Domain Controlled Source Electromagnetics in Shallow Water, 1: Isotropic Conductivity

    Science.gov (United States)

    Chave, Alan D.; Everett, Mark E.; Mattsson, Johan; Boon, James; Midgley, Jonathan

    2016-11-01

    In recent years, marine controlled source electromagnetics (CSEM) has found increasing use in hydrocarbon exploration due to its ability to detect thin resistive zones beneath the seafloor. It is the purpose of this paper to evaluate the physics of CSEM for an ocean whose electrical thickness is comparable to or much thinner than that of the overburden using the in-line configuration through examination of the elliptically-polarized seafloor electric field, the time-averaged energy flow depicted by the real part of the complex Poynting vector, energy dissipation through Joule heating and the Fréchet derivatives of the seafloor field with respect to the sub-seafloor conductivity that is assumed to be isotropic. The deep water (ocean layer electrically much thicker than the overburden) seafloor electromagnetic response for a model containing a resistive reservoir layer has a greater amplitude and reduced phase as a function of offset compared to that for a halfspace, or a stronger and faster response. For an ocean whose electrical thickness is comparable to or much smaller than that of the overburden, the electric field displays a greater amplitude and reduced phase at small offsets, shifting to a stronger amplitude and increased phase at intermediate offsets, and a weaker amplitude and enhanced phase at long offsets, or a stronger and faster response that first changes to stronger and slower, and then transitions to weaker and slower. These transitions can be understood by visualizing the energy flow throughout the structure caused by the competing influences of the dipole source and guided energy flow in the reservoir layer, and the air interaction caused by coupling of the entire sub-seafloor resistivity structure with the sea surface. A stronger and faster response occurs when guided energy flow is dominant, while a weaker and slower response occurs when the air interaction is dominant. However, at intermediate offsets for some models, the air interaction can

  14. Data/MC Comparison for ECAL and HCAL

    CERN Document Server

    CMS Collaboration

    2016-01-01

    CMS has tuned its simulation program and chosen a specific physics model of Geant4 by comparing the simulation results with dedicated test beam experiments. CMS continues to validate the physics models inside Geant4 using the test beam data as well as collision data. Several physics lists (collection of physics models) inside the most recent version of Geant4 provide good agreement of the energy response, resolution of pions and protons. The validation results from these studies will be presented. Shower shapes of electrons and photons evaluate the goodness of the description of electromagnetic physics in Geant4 while response of isolated charged particles are used to examine the predictions of hadronic models within Geant4. Use of Geant4 to explain rare anomalous hits in the calorimeter will also be discussed.

  15. Didactical Reconstruction of Processes in Knowledge Construction: Pre-service Physics Teachers Learning the Law of Electromagnetic Induction

    Science.gov (United States)

    Mäntylä, Terhi

    2012-08-01

    In physics teacher education, two central goals are first to learn the structures of physics knowledge, and second the processes of its construction. To know the structure is to know the framework of concepts and laws; to know the processes is to know where the knowledge comes from, how the framework is constructed, and how it can be justified. This article introduces a way to approach these goals in the form of a graphical tool called the didactical reconstruction of processes (DRP), where knowledge is constructed to the extent that experiments and models have an equally important role in the construction process. In practice, the DRP is a graphical network representation or a `flow chart' with a specific structure, which aims to give an image of the processes of physical concept formation, while at the same time bearing in mind the educational goals. The DRP was tested in an instruction unit for pre-service physics teachers, where students drew flow charts for representing how the law of electromagnetic induction is formed. In addition to flow charts, students also wrote essays clarifying the content of the flow charts. The flow charts and essays were analysed through a qualitative categorisation of structural and knowledge claim patterns. The results show that the DRP helps students in arguing how to form the electromagnetic induction law and that the experiments and models have a distinct role in supporting students' knowledge claims.

  16. International Wilhelm and Else Heraeus Physics School: Diffractive and electromagnetic processes at high energies

    CERN Document Server

    2015-01-01

    The school "Diffractive and electromagnetic processes at high energies" is held in Bad Honnef, August 17-21, 2015. Applications from students and postdocs are encouraged. The school programme consists of invited talks of the HERA, RHIC, TEVATRON and CERN programmes, invited lectures and talks contributed by the participants.

  17. ON THE PHYSICS OF GALVANIC SOURCE ELECTROMAGNETIC GEOPHYSICAL METHODS FOR TERRESTRIAL AND MARINE EXPLORATION

    Energy Technology Data Exchange (ETDEWEB)

    David Alumbaugh and Evan Um

    2007-06-27

    A numerical study was conducted to investigate the governing physics of galvanic source electromagnetic (EM) methods for terrestrial and marine exploration scenarios. The terrestrial exploration scenario involves the grounded electric dipole source EM (GESTEM) method and the examination of how the GESTEM method can resolve a thin resistive layer representing underground gas and/or hydrocarbon storage. Numerical modeling studies demonstrate that the loop transient EM (TEM) and magnetotelluric (MT) methods are insensitive to a thin horizontal resistor at depth because they utilize horizontal currents. In contrast to these standard EM methods, the GESTEM method generates both vertical and horizontal transient currents. The vertical transient current interacts with a thin horizontal resistor and causes charge buildup on its surface. These charges produce a measurable perturbation in the surface electric field at early time. The degree of perturbation depends on source waveform. When the GESTEM method is energized with step-off waveform, the perturbation due to a thin horizontal resistor is small. This is because the step-off waveform mainly consists of low frequency signals. An alternative is taking the time-derivative of the step-off responses to approximate the impulse response which includes higher frequency signals. In order to improve degree of perturbation especially due to a localized small 3-D resistor, the diffusion angle of the vertical transient current, 45 should be considered to make vertical currents coupled to a resistive target efficiently. The major drawback of the GESTEM method lies in the fact that GESTEM sounding can not be interpreted using 1-D inversion schemes if there is near-surface inhomogeneity. The marine exploration scenario investigates the physics of marine frequency-domain controlled source EM (FDCSEM) and time-domain controlled source EM (TDCSEM) methods to explore resistive hydrocarbon reservoirs in marine environments. Unlike the

  18. On the physics of frequency-domain controlled source electromagnetics in shallow water. 1: isotropic conductivity

    Science.gov (United States)

    Chave, Alan D.; Everett, Mark E.; Mattsson, Johan; Boon, James; Midgley, Jonathan

    2017-02-01

    In recent years, marine controlled source electromagnetics (CSEM) has found increasing use in hydrocarbon exploration due to its ability to detect thin resistive zones beneath the seafloor. It is the purpose of this paper to evaluate the physics of CSEM for an ocean whose electrical thickness is comparable to or much thinner than that of the overburden using the in-line configuration through examination of the elliptically polarized seafloor electric field, the time-averaged energy flow depicted by the real part of the complex Poynting vector, energy dissipation through Joule heating and the Fréchet derivatives of the seafloor field with respect to the subseafloor conductivity that is assumed to be isotropic. The deep water (ocean layer electrically much thicker than the overburden) seafloor EM response for a model containing a resistive reservoir layer has a greater amplitude and reduced phase as a function of offset compared to that for a half-space, or a stronger and faster response. For an ocean whose electrical thickness is comparable to or much smaller than that of the overburden, the electric field displays a greater amplitude and reduced phase at small offsets, shifting to a stronger amplitude and increased phase at intermediate offsets and a weaker amplitude and enhanced phase at long offsets, or a stronger and faster response that first changes to stronger and slower, and then transitions to weaker and slower. These transitions can be understood by visualizing the energy flow throughout the structure caused by the competing influences of the dipole source and guided energy flow in the reservoir layer, and the air interaction caused by coupling of the entire subseafloor resistivity structure with the sea surface. A stronger and faster response occurs when guided energy flow is dominant, while a weaker and slower response occurs when the air interaction is dominant. However, at intermediate offsets for some models, the air interaction can partially or

  19. Response of the CALICE Si-W Electromagnetic Calorimeter Physics Prototype to Electrons

    CERN Document Server

    Adloff, C.; Repond, J.; Yu, J.; Eigen, G.; Hawkes, C.M.; Mikami, Y.; Miller, O.; Watson, N.K.; Wilson, J.A.; Goto, T.; Mavromanolakis, G.; Thomson, M.A.; Ward, D.R.; Yan, W.; Benchekroun, D.; Hoummada, A.; Krim, M.; Benyamna, M.; Boumediene, D.; Brun, N.; Carloganu, C.; Gay, P.; Morisseau, F.; Blazey, G.C.; Chakraborty, D.; Dyshkant, A.; Francis, K.; Hedin, D.; Lima, G.; Zutshi, V.; Hostachy, J.-Y.; Morin, L.; D'Ascenzo, N.; Cornett, U.; David, D.; Fabbri, R.; Falley, G.; Gadow, K.; Garutti, E.; Gottlicher, P.; Jung, T.; Karstensen, S.; Korbel, V.; Lucaci-Timoce, A.-I.; Lutz, B.; Meyer, N.; Morgunov, V.; Reinecke, M.; Sefkow, F.; Smirnov, P.; Vargas-Trevino, A.; Wattimena, N.; Wendt, O.; Feege, N.; Groll, M.; Haller, J.; Heuer, R.-D.; Richter, S.; Samson, J.; Kaplan, A.; Schultz-Coulon, H.-Ch.; Shen, W.; Tadday, A.; Bilki, B.; Norbeck, E.; Onel, Y.; Kim, E.J.; Baek, N.I.; Kim, D-W.; Lee, K.; Lee, S.C.; Kawagoe, K.; Tamura, Y.; Bowerman, D.A.; Dauncey, P.D.; Magnan, A.-M.; Yilmaz, H.; Zorba, O.; Bartsch, V.; Postranecky, M.; Warren, M.; Wing, M.; Faucci Giannelli, M.; Green, M.G.; Salvatore, F.; Bedjidian, M.; Kieffer, R.; Laktineh, I.; Bailey, D.S.; Barlow, R.J.; Kelly, M.; Thompson, R.J.; Danilov, M.; Tarkovsky, E.; Baranova, N.; Karmanov, D.; Korolev, M.; Merkin, M.; Voronin, A.; Frey, A.; Lu, S.; Prothmann, K.; Simon, F.; Bouquet, B.; Callier, S.; Cornebise, P.; Fleury, J.; Li, H.; Richard, F.; de la Taille, Ch.; Poeschl, R.; Raux, L.; Ruan, M.; Seguin-Moreau, N.; Wicek, F.; Anduze, M.; Boudry, V.; Brient, J-C.; Gaycken, G.; Mora de Freitas, P.; Musat, G.; Reinhard, M.; Rouge, A.; Vanel, J-Ch.; Videau, H.; Park, K-H.; Zacek, J.; Cvach, J.; Gallus, P.; Havranek, M.; Janata, M.; Marcisovsky, M.; Polak, I.; Popule, J.; Tomasek, L.; Tomasek, M.; Ruzicka, P.; Sicho, P.; Smolik, J.; Vrba, V.; Zalesak, J.; Belhorma, B.; Belmir, M.; Nam, S.W.; Park, I.H.; Yang, J.; Chai, J.-S.; Kim, J.-T.; Kim, G.-B.; Kang, J.; Kwon, Y.-J.

    2009-01-01

    A prototype Silicon-Tungsten electromagnetic calorimeter (ECAL) for an International Linear Collider (ILC) detector was installed and tested during summer and autumn 2006 at CERN. The detector had 6480 silicon pads of dimension 1x1 cm^2. Data were collected with electron beams in the energy range 6 to 45 GeV. The analysis described in this paper focuses on electromagnetic shower reconstruction and characterises the ECAL response to electrons in terms of energy resolution and linearity. The detector is linear to within approximately the 1% level and has a relative energy resolution of (16.6 +- 0.1)/ \\sqrt{E(GeV}) + 1.1 +- 0.1 (%). The spatial uniformity and the time stability of the ECAL are also addressed.

  20. Multi-physics modeling of large ring motor for mining industry - Combining electromagnetism, fluid mechanics, mass and heat transfer in engineering design

    DEFF Research Database (Denmark)

    Andersen, Søren Bøgh; Santos, Ilmar F.; Fuerst, Axel

    2015-01-01

    electromagnet, thermal and structural interactions. This multi-physics model will later on be used for simulating and parameter optimization of a gearless mill drive. What has been proposed is a multi-physics model where the core losses are determined through a series of static finite element magnetic...

  1. New perspectives on classical electromagnetism

    OpenAIRE

    Cote, Paul J.

    2009-01-01

    The fallacies associated with the gauge concept in electromagnetism are illustrated. A clearer and more valid formulation of the basics of classical electromagnetism is provided by recognizing existing physical constraints as well as the physical reality of the vector potential.

  2. Influence of the geometrical detail in the description of DNA and the scoring method of ionization clustering on nanodosimetric parameters of track structure: a Monte Carlo study using Geant4-DNA

    Science.gov (United States)

    Bueno, M.; Schulte, R.; Meylan, S.; Villagrasa, C.

    2015-11-01

    The aim of this study was to evaluate the influence of the geometrical detail of the DNA on nanodosimetric parameters of track structure induced by protons and alpha particles of different energies (LET values ranging from 1 to 162.5~\\text{keV}~μ {{\\text{m}}-1} ) as calculated by Geant4-DNA Monte Carlo simulations. The first geometry considered consisted of a well-structured placement of a realistic description of the DNA double helix wrapped around cylindrical histones (GeomHist) forming a 18 kbp-long chromatin fiber. In the second geometry considered, the DNA was modeled as a total of 1800 ten bp-long homogeneous cylinders (2.3 nm diameter and 3.4 nm height) placed in random positions and orientations (GeomCyl). As for GeomHist, GeomCyl contained a DNA material equivalent to 18 kbp. Geant4-DNA track structure simulations were performed and ionizations were counted in the scoring volumes. For GeomCyl, clusters were defined as the number of ionizations (ν) scored in each 10 bp-long cylinder. For GeomHist, clusters of ionizations scored in the sugar-phosphate groups of the double-helix were revealed by the DBSCAN clustering algorithm according to a proximity criteria among ionizations separated by less than 10 bp. The topology of the ionization clusters formed using GeomHist and GeomCyl geometries were compared in terms of biologically relevant nanodosimetric quantities. The discontinuous modeling of the DNA for GeomCyl led to smaller cluster sizes than for GeomHist. The continuous modeling of the DNA molecule for GeomHist allowed the merging of ionization points by the DBSCAN algorithm giving rise to larger clusters, which were not detectable within the GeomCyl geometry. Mean cluster size (m1) was found to be of the order of 10% higher for GeomHist compared to GeomCyl for LET <15~\\text{keV}~μ {{\\text{m}}-1} . For higher LETs, the difference increased with LET similarly for protons and alpha particles. Both geometries showed the same relationship

  3. Framing the Structural Role of Mathematics in Physics Lectures: A Case Study on Electromagnetism

    Science.gov (United States)

    Karam, Ricardo

    2014-01-01

    Physics education research has shown that students tend to struggle when trying to use mathematics in a meaningful way in physics (e.g., mathematizing a physical situation or making sense of equations). Concerning the possible reasons for these difficulties, little attention has been paid to the way mathematics is treated in physics instruction.…

  4. Framing the Structural Role of Mathematics in Physics Lectures: A Case Study on Electromagnetism

    Science.gov (United States)

    Karam, Ricardo

    2014-01-01

    Physics education research has shown that students tend to struggle when trying to use mathematics in a meaningful way in physics (e.g., mathematizing a physical situation or making sense of equations). Concerning the possible reasons for these difficulties, little attention has been paid to the way mathematics is treated in physics instruction.…

  5. Determination and Fabrication of New Shield Super Alloys Materials for Nuclear Reactor Safety by Experiments and Cern-Fluka Monte Carlo Simulation Code, Geant4 and WinXCom

    Science.gov (United States)

    Aygun, Bünyamin; Korkut, Turgay; Karabulut, Abdulhalik

    2016-05-01

    Despite the possibility of depletion of fossil fuels increasing energy needs the use of radiation tends to increase. Recently the security-focused debate about planned nuclear power plants still continues. The objective of this thesis is to prevent the radiation spread from nuclear reactors into the environment. In order to do this, we produced higher performanced of new shielding materials which are high radiation holders in reactors operation. Some additives used in new shielding materials; some of iron (Fe), rhenium (Re), nickel (Ni), chromium (Cr), boron (B), copper (Cu), tungsten (W), tantalum (Ta), boron carbide (B4C). The results of this experiments indicated that these materials are good shields against gamma and neutrons. The powder metallurgy technique was used to produce new shielding materials. CERN - FLUKA Geant4 Monte Carlo simulation code and WinXCom were used for determination of the percentages of high temperature resistant and high-level fast neutron and gamma shielding materials participated components. Super alloys was produced and then the experimental fast neutron dose equivalent measurements and gamma radiation absorpsion of the new shielding materials were carried out. The produced products to be used safely reactors not only in nuclear medicine, in the treatment room, for the storage of nuclear waste, nuclear research laboratories, against cosmic radiation in space vehicles and has the qualities.

  6. Geant4 simulation of the PSI LEM beam line: energy loss and muonium formation in thin foils and the impact of unmoderated muons on the $\\mu$SR spectrometer

    CERN Document Server

    Khaw, Kim Siang; Crivelli, Paolo; Kirch, Klaus; Morenzoni, Elvezio; Salman, Zaher; Suter, Andreas; Prokscha, Thomas

    2015-01-01

    The PSI low-energy $\\mu$SR spectrometer is an instrument dedicated to muon spin rotation and relaxation measurements. Knowledge of the muon beam parameters such as spatial, kinetic energy and arrival-time distributions at the sample position are important ingredients to analyze the $\\mu$SR spectra. We present here the measured energy losses in the thin carbon foil of the muon start detector deduced from time-of-flight measurements. Muonium formation in the thin carbon foil (10 nm thickness) of the muon start detector also affect the measurable decay asymmetry and therefore need to be accounted for. Muonium formation and energy losses in the start detector, whose relevance increase with decreasing muon implantation energy ($<10$ keV), have been implemented in Geant4 Monte Carlo simulation to reproduce the measured time-of-flight spectra. Simulated and measured time-of-flight and beam spot agrees only if a small fraction of so called "unmoderated" muons which contaminate the mono-energetic muon beam of the $...

  7. Simulation studies of crystal-photodetector assemblies for the Turkish accelerator center particle factory electromagnetic calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Kocak, F., E-mail: fkocak@uludag.edu.tr

    2015-07-01

    The Turkish Accelerator Center Particle Factory detector will be constructed for the detection of the produced particles from the collision of a 1 GeV electron beam against a 3.6 GeV positron beam. PbWO{sub 4} and CsI(Tl) crystals are considered for the construction of the electromagnetic calorimeter part of the detector. The generated optical photons in these crystals are detected by avalanche or PIN photodiodes. Geant4 simulation code has been used to estimate the energy resolution of the calorimeter for these crystal–photodiode assemblies.

  8. Sensitivity study of proton radiography and comparison with kV and MV x-ray imaging using GEANT4 Monte Carlo simulations.

    Science.gov (United States)

    Depauw, Nicolas; Seco, Joao

    2011-04-21

    The imaging sensitivity of proton radiography has been studied and compared with kV and MV x-ray imaging using Monte Carlo simulations. A phantom was specifically modeled using 21 different material inserts with densities ranging from 0.001 to 1.92 g cm(-3). These simulations were run using the MGH double scattered proton beam, scanned pencil proton beams from 200 to 490 MeV, as well as pure 50 keV, 100 keV, 1 MeV and 2 MeV gamma x-ray beams. In order to compare the physics implied in both proton and photon radiography without being biased by the current state of the art in detector technology, the detectors were considered perfect. Along with spatial resolution, the contrast-to-noise ratio was evaluated and compared for each material. These analyses were performed using radiographic images that took into account the following: only primary protons, both primary and secondary protons, and both contributions while performing angular and energetic cuts. Additionally, tissue-to-tissue contrasts in an actual lung cancer patient case were studied for simulated proton radiographs and compared against the original kV x-ray image which corresponds to the current patient set-up image in the proton clinic. This study highlights the poorer spatial resolution of protons versus x-rays for radiographic imaging purposes, and the excellent density resolution of proton radiography. Contrasts around the tumor are higher using protons in a lung cancer patient case. The high-density resolution of proton radiography is of great importance for specific tumor diagnostics, such as in lung cancer, where x-ray radiography operates poorly. Furthermore, the use of daily proton radiography prior to proton therapy would ameliorate patient set-up while reducing the absorbed dose delivered through imaging.

  9. The use of history of science in physics teaching: an application for electromagnetism

    Directory of Open Access Journals (Sweden)

    María Andrea Perea

    2016-06-01

    Full Text Available The present is a revision of different proposals that utilize History of Science in teaching. They have been grouped according to the purpose they pursue: to evoke discoveries, to highlight the human aspect of Science through the contributions of renamed scientists, to teach the processes of scientific construction, to detect students' preconceptions and teach concepts, and to highlight the socio-cultural basis of scientific ideas and research. We discuss why we consider that this last aspect includes the other ones, and elaborate general guidelines for the use of HC in a particular case dealing with electromagnetic field. Our proposal is focused on the controversy between "action-at-a-distance" and "field", and is elaborated on the basis of key experiments carried out by Heinrich Hertz.

  10. Nucleon electromagnetic form factors using lattice simulations at the physical point

    Science.gov (United States)

    Alexandrou, C.; Constantinou, M.; Hadjiyiannakou, K.; Jansen, K.; Kallidonis, Ch.; Koutsou, G.; Vaquero Aviles-Casco, A.

    2017-08-01

    We present results for the nucleon electromagnetic form factors using an ensemble of maximally twisted mass clover-improved fermions with pion mass of about 130 MeV. We use multiple sink-source separations and three analysis methods to probe ground-state dominance. We evaluate both the connected and disconnected contributions to the nucleon matrix elements. We find that the disconnected quark loop contributions to the isoscalar matrix elements are small, giving an upper bound of up to 2% of the connected and smaller than its statistical error. We present results for the isovector and isoscalar electric and magnetic Sachs form factors and the corresponding proton and neutron form factors. By fitting the momentum dependence of the form factors to a dipole form or to the z expansion, we extract the nucleon electric and magnetic radii, as well as the magnetic moment. We compare our results to experiment as well as to other recent lattice QCD calculations.

  11. Electromagnetism Unit of an Introductory University Physics Course: The Influence of a Reform-Based Tutorial

    Science.gov (United States)

    Barrett, Sarah Elizabeth; Hazari, Zahra; Fatholahzadeh, Baharak; Harrison, David M.

    2012-01-01

    Many students enrolled in university physics have little interest in the subject matter, a trend more pronounced in females. This study assesses students' conceptual understanding and interest during the electrochemistry unit of a physics course for nonphysics majors that was revised in light of consistently low ratings from its students. The…

  12. Theory of electromagnetic fields

    CERN Document Server

    Wolski, Andrzej

    2011-01-01

    We discuss the theory of electromagnetic fields, with an emphasis on aspects relevant to radiofrequency systems in particle accelerators. We begin by reviewing Maxwell's equations and their physical significance. We show that in free space, there are solutions to Maxwell's equations representing the propagation of electromagnetic fields as waves. We introduce electromagnetic potentials, and show how they can be used to simplify the calculation of the fields in the presence of sources. We derive Poynting's theorem, which leads to expressions for the energy density and energy flux in an electromagnetic field. We discuss the properties of electromagnetic waves in cavities, waveguides and transmission lines.

  13. Prospects of hadron and quark physics with electromagnetic probes. Proceedings of the second ELFE workshop on Hadronic Physics

    Energy Technology Data Exchange (ETDEWEB)

    D' Hose, N.; Frois, B.; Guichon, P.A.M. [CEA Saclay, 91 - Gif-sur-Yvette (France). Dept. d' Astrophysique, de la Physique des Particules, de la Physique Nucleaire et de l' Instrumentation Associee; Pire, B. [Ecole Polytechnique, 91 - Palaiseau (France). Centre de Physique Theorique; Van de Wiele, J. [Institut de Physique Nucleaire, 91 - Orsay (France). Division de Recherche Experimentale

    1996-07-01

    The last three days of the second ELFE workshop on confinement physics were devoted to the results of the work during the past year on the update and improvement of the physics case, the feasibility of the ELFE at DESY project(which combines the HERA ring used as a stretcher and a low duty factor 25 GeV electron linac which could be either a section of the TESLA collider or the injector of the foreseen short wave length free electron laser) as well as the development of the detectors. The participations have been decided into 5 copies: inclusive and semi-inclusive reactions; real photon physics, exclusive reactions; color transparency; detectors. (author)

  14. Non-specific physical symptoms and electromagnetic field exposure in the general population: can we get more specific? A systematic review.

    NARCIS (Netherlands)

    Baliatsas, C.; Kamp, I. van; Bolte, J.; Schipper, M.; Yzermans, J.; Lebret, E.

    2012-01-01

    OBJECTIVE: A systematic review of observational studies was performed to address the strength of evidence for an association between actual and perceived exposure to electromagnetic fields (EMF) and non-specific physical symptoms (NSPS) in the general population. To gain more insight into the magnit

  15. Multiple scattering Model in GEANT4

    CERN Document Server

    Urbàn, L

    2002-01-01

    We present a new multiple scattering (MSC) model to simulate the multiple scattering of charged particles in matter. This model does not use the Moliere formalism, it is based on the more complete Lewis theory. The model simulates the scattering of the particle after a given step, computes the path length correction and the lateral displacement as well.

  16. SU-E-T-289: Scintillating Fiber Based In-Vivo Dose Monitoring System to the Rectum in Proton Therapy of Prostate Cancer: A Geant4 Monte Carlo Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Tesfamicael, B; Gueye, P; Lyons, D [Hampton University, Hampton, VA (United States); Mahesh, M [Johns Hopkins Univ, Baltimore, MD (United States); Avery, S [University of Pennsylvania, Sicklerville, NJ (United States)

    2014-06-01

    Purpose: To construct a dose monitoring system based on an endorectal balloon coupled to thin scintillating fibers to study the dose delivered to the rectum during prostate cancer proton therapy Methods: The Geant4 Monte Carlo toolkit version 9.6p02 was used to simulate prostate cancer proton therapy treatments of an endorectal balloon (for immobilization of a 2.9 cm diameter prostate gland) and a set of 34 scintillating fibers symmetrically placed around the balloon and perpendicular to the proton beam direction (for dosimetry measurements) Results: A linear response of the fibers to the dose delivered was observed within <2%, a property that makes them good candidates for real time dosimetry. Results obtained show that the closest fiber recorded about 1/3 of the dose to the target with a 1/r{sup 2} decrease in the dose distribution as one goes toward the frontal and distal top fibers. Very low dose was recorded by the bottom fibers (about 45 times comparatively), which is a clear indication that the overall volume of the rectal wall that is exposed to a higher dose is relatively minimized. Further analysis indicated a simple scaling relationship between the dose to the prostate and the dose to the top fibers (a linear fit gave a slope of −0.07±0.07 MeV per treatment Gy) Conclusion: Thin (1 mm × 1 mm × 100 cm) long scintillating fibers were found to be ideal for real time in-vivo dose measurement to the rectum for prostate cancer proton therapy. The linear response of the fibers to the dose delivered makes them good candidates of dosimeters. With thorough calibration and the ability to define a good correlation between the dose to the target and the dose to the fibers, such dosimeters can be used for real time dose verification to the target.

  17. Dosimetry for electron Intra-Operative RadioTherapy: Comparison of output factors obtained through alanine/EPR pellets, ionization chamber and Monte Carlo-GEANT4 simulations for IORT mobile dedicate accelerator

    Science.gov (United States)

    Marrale, Maurizio; Longo, Anna; Russo, Giorgio; Casarino, Carlo; Candiano, Giuliana; Gallo, Salvatore; Carlino, Antonio; Brai, Maria

    2015-09-01

    In this work a comparison between the response of alanine and Markus ionization chamber was carried out for measurements of the output factors (OF) of electron beams produced by a linear accelerator used for Intra-Operative Radiation Therapy (IORT). Output factors (OF) for conventional high-energy electron beams are normally measured using ionization chamber according to international dosimetry protocols. However, the electron beams used in IORT have characteristics of dose per pulse, energy spectrum and angular distribution quite different from beams usually used in external radiotherapy, so the direct application of international dosimetry protocols may introduce additional uncertainties in dosimetric determinations. The high dose per pulse could lead to an inaccuracy in dose measurements with ionization chamber, due to overestimation of ks recombination factor. Furthermore, the electron fields obtained with IORT-dedicated applicators have a wider energy spectrum and a wider angular distribution than the conventional fields, due to the presence of electrons scattered by the applicator's wall. For this reason, a dosimetry system should be characterized by a minimum dependence from the beam energy and from angle of incidence of electrons. This become particularly critical for small and bevelled applicators. All of these reasons lead to investigate the use of detectors different from the ionization chamber for measuring the OFs. Furthermore, the complete characterization of the radiation field could be accomplished also by the use of Monte Carlo simulations which allows to obtain detailed information on dose distributions. In this work we compare the output factors obtained by means of alanine dosimeters and Markus ionization chamber. The comparison is completed by the Monte Carlo calculations of OFs determined through the use of the Geant4 application "iort _ therapy" . The results are characterized by a good agreement of response of alanine pellets and Markus

  18. A first class constraint generates not a gauge transformation, but a bad physical change: The case of electromagnetism

    Science.gov (United States)

    Pitts, J. Brian

    2014-12-01

    In Dirac-Bergmann constrained dynamics, a first-class constraint typically does not alone generate a gauge transformation. By direct calculation it is found that each first-class constraint in Maxwell's theory generates a change in the electric field E → by an arbitrary gradient, spoiling Gauss's law. The secondary first-class constraint pi,i = 0 still holds, but being a function of derivatives of momenta (mere auxiliary fields), it is not directly about the observable electric field (a function of derivatives of Aμ), which couples to charge. Only a special combination of the two first-class constraints, the Anderson-Bergmann-Castellani gauge generator G, leaves E → unchanged. Likewise only that combination leaves the canonical action invariant-an argument independent of observables. If one uses a first-class constraint to generate instead a canonical transformation, one partly strips the canonical coordinates of physical meaning as electromagnetic potentials, vindicating the Anderson-Bergmann Lagrangian orientation of interesting canonical transformations. The need to keep gauge-invariant the relation q ˙ -δH/δp = -Ei -pi = 0 supports using the gauge generator and primary Hamiltonian rather than the separate first-class constraints and the extended Hamiltonian. Partly paralleling Pons's criticism, it is shown that Dirac's proof that a first-class primary constraint generates a gauge transformation, by comparing evolutions from identical initial data, cancels out and hence fails to detect the alterations made to the initial state. It also neglects the arbitrary coordinates multiplying the secondary constraints inside the canonical Hamiltonian. Thus the gauge-generating property has been ascribed to the primaries alone, not the primary-secondary team G. Hence the Dirac conjecture about secondary first-class constraints as generating gauge transformations rests upon a false presupposition about primary first-class constraints. Clarity about Hamiltonian

  19. Pulsed electromagnetic field therapy for management of osteoarthritis-related pain, stiffness and physical function: clinical experience in the elderly

    Directory of Open Access Journals (Sweden)

    Iannitti T

    2013-09-01

    Full Text Available Tommaso Iannitti,1,2 Gregorio Fistetto,2 Anna Esposito,2 Valentina Rottigni,2,3 Beniamino Palmieri2,3 1Department of Physiology, University of Kentucky Medical Center, Lexington, KY, USA; 2Poliambulatorio del Secondo Parere, Modena, Italy; 3Department of General Surgery and Surgical Specialties, University of Modena and Reggio Emilia Medical School, Surgical Clinic, Modena, Italy Background: Pulsed electromagnetic field (PEMF therapy has shown promising therapeutic effectiveness on bone- and cartilage-related pathologies, being also safe for management of knee osteoarthritis. Aim: The aim of this study was to investigate the clinical efficacy of a PEMF device for management of knee osteoarthritis in elderly patients. Materials and methods: A total of 33 patients were screened, and 28 patients, aged between 60 and 83 and affected by bilateral knee osteoarthritis, were enrolled in this study. They received PEMF therapy on the right leg for a total of three 30-minute sessions per week for a period of 6 weeks, while the left leg did not receive any treatment and served as control. An intravenous drip containing ketoprofen, sodium clodronate, glucosamine sulfate, calcitonin, and ascorbic acid, for a total volume of 500 mL, was administered during PEMF therapy. At baseline and 3 months post-PEMF therapy, Visual Analog Scale (VAS was used to assess knee pain and Western Ontario McMaster Universities Osteoarthritis Index (WOMAC was used to measure knee pain, stiffness and physical function. Results: Changes in VAS and WOMAC scores were calculated for both knees as baseline minus post-treatment. A two sample Student’s t-test, comparing change in knee-related VAS pain for PEMF-treated leg (49.8 ± 2.03 vs control leg (11 ± 1.1, showed a significant difference in favor of PEMF therapy (P < 0.001. A two sample Student’s t-test comparing change in knee-related WOMAC pain, stiffness, and physical function for PEMF-treated leg (8.5 ± 0.4, 3.5 ± 0.2, 38

  20. Role of the CMS electromagnetic calorimeter in the measurement of the Higgs boson properties and search for new physics

    Science.gov (United States)

    Ferri, F.; CMS Collaboration

    2016-04-01

    The precise determination of the mass, the width and the couplings of the particle discovered in 2012 with a mass around 125 GeV is of capital importance to clarify the nature of such a particle, in particular to establish precisely if it is a Standard Model Higgs boson. In several new physics scenarios, in fact, the Higgs boson may behave differently with respect to the Standard Model one, or may not be unique, i.e. there can be more than one Higgs boson. In order to achieve the precision needed to discriminate between different models, the energy resolution, the scale uncertainty and the position resolution for electrons and photons are required to be as good as possible. The CMS scintillating lead-tungstate electromagnetic calorimeter (ECAL) was built as a precise tool with an exceptional energy resolution and a very good position resolution that improved over the years with the knowledge of the detector. Moreover, thanks to the fact that most of the lead-tungstate scintillation light is emitted in about 25 ns, the ECAL can be used to accurately determine the time of flight of photons. We present the current performance of the CMS ECAL, with a special emphasis on the impact on the measurement of the properties of the Higgs boson and on searches for new physics.

  1. Basic Electromagnetism and Materials

    CERN Document Server

    Moliton, André

    2007-01-01

    Basic Electromagnetism and Materials is the product of many years of teaching basic and applied electromagnetism. This textbook can be used to teach electromagnetism to a wide range of undergraduate science majors in physics, electrical engineering or materials science. However, by making lesser demands on mathematical knowledge than competing texts, and by emphasizing electromagnetic properties of materials and their applications, this textbook is uniquely suited to students of materials science. Many competing texts focus on the study of propagation waves either in the microwave or optical domain, whereas Basic Electromagnetism and Materials covers the entire electromagnetic domain and the physical response of materials to these waves. Professor André Moliton is Director of the Unité de Microélectronique, Optoélectronique et Polymères (Université de Limoges, France), which brings together three groups studying the optoelectronics of molecular and polymer layers, micro-optoelectronic systems for teleco...

  2. Pulsed electromagnetic field therapy for management of osteoarthritis-related pain, stiffness and physical function: clinical experience in the elderly.

    Science.gov (United States)

    Iannitti, Tommaso; Fistetto, Gregorio; Esposito, Anna; Rottigni, Valentina; Palmieri, Beniamino

    2013-01-01

    Pulsed electromagnetic field (PEMF) therapy has shown promising therapeutic effectiveness on bone- and cartilage-related pathologies, being also safe for management of knee osteoarthritis. The aim of this study was to investigate the clinical efficacy of a PEMF device for management of knee osteoarthritis in elderly patients. A total of 33 patients were screened, and 28 patients, aged between 60 and 83 and affected by bilateral knee osteoarthritis, were enrolled in this study. They received PEMF therapy on the right leg for a total of three 30-minute sessions per week for a period of 6 weeks, while the left leg did not receive any treatment and served as control. An intravenous drip containing ketoprofen, sodium clodronate, glucosamine sulfate, calcitonin, and ascorbic acid, for a total volume of 500 mL, was administered during PEMF therapy. At baseline and 3 months post-PEMF therapy, Visual Analog Scale (VAS) was used to assess knee pain and Western Ontario McMaster Universities Osteoarthritis Index (WOMAC) was used to measure knee pain, stiffness and physical function. Changes in VAS and WOMAC scores were calculated for both knees as baseline minus post-treatment. A two sample Student's t-test, comparing change in knee-related VAS pain for PEMF-treated leg (49.8 ± 2.03) vs control leg (11 ± 1.1), showed a significant difference in favor of PEMF therapy (P physical function for PEMF-treated leg (8.5 ± 0.4, 3.5 ± 0.2, 38.5 ± 2.08, respectively) vs control leg (2.6 ± 0.2; 1.6 ± 0.1; 4.5 ± 0.5 respectively), also showed a significant difference in favor of PEMF therapy (P therapy were observed. The present study shows that PEMF therapy improves pain, stiffness and physical function in elderly patients affected by knee osteoarthritis.

  3. Physics and applications of high energy density plasmas. Extreme state driven by pulsed electromagnetic energy

    Energy Technology Data Exchange (ETDEWEB)

    Horioka, Kazuhiko (ed.)

    2002-06-01

    The papers presented at the symposium on ''Physics and application of high energy density plasmas, held December 20-21, 2001 at NIFS'' are collected in this proceedings. The topics covered in the meeting include dense z-pinches, plasma focus, intense charged particle beams, intense radiation sources, discharge pumped X-ray lasers, their diagnostics, and applications of them. The papers reflect the present status and trends in the research field of high energy density plasmas. (author)

  4. A First Class Constraint Generates Not a Gauge Transformation, But a Bad Physical Change: The Case of Electromagnetism

    CERN Document Server

    Pitts, J Brian

    2013-01-01

    In constrained dynamics, a first-class constraint typically does not_alone_ generate a gauge transformation. Each first-class constraint in Maxwell's theory changes the electric field by an arbitrary gradient, spoiling Gauss's law. The secondary p^i,_i=0 still holds, but being a function of derivatives of momenta, it is not directly about E (a function of derivatives of A_\\mu). Only a special combination of first-class constraints, the Anderson-Bergmann-Castellani gauge generator G, leaves E unchanged. This problem is avoided if one uses a first-class constraint as the generator of a_canonical transformation_; but that partly strips the canonical coordinates of physical meaning as electromagnetic potentials. Keeping gauge-invariant \\dot{q}- dH/dp= -E -p =0 supports using the primary rather than the extended Hamiltonian. The results extend the Lagrangian-oriented reforms of Castellani, Sugano, Pons, Salisbury, Shepley, etc. by showing the inequivalence of the extended Hamiltonian to the primary Hamiltonian (an...

  5. Role of the CMS electromagnetic calorimeter in the measurement of the Higgs boson properties and search for new physics

    CERN Document Server

    Ferri, Federico

    2014-01-01

    The precise determination of the mass, the width and the couplings of the particle discovered in 2012 around 125 GeV is of capital importance to clarify the nature of such a particle, in particular to establish precisely if it is a Standard Higgs boson. In several new physics scenarios, in fact, a Higgs boson may behave differently with respect to the Standard one, or may not be unique, i.e. there can be more than one Higgs boson. In order to achieve the precision needed to discriminate between different models, the energy resolution, the scale uncertainty and the position resolution for electrons and photons are required to be as good as possible. The CMS scintillating lead-tungstate electromagnetic calorimeter (ECAL) was built as a precise tool with an exceptional energy resolution and a very good position resolution that improved over the years with the knowledge of the detector. Moreover, thanks to the fact that most of the lead-tungstate scintillation light is emitted in about 25 ns, ECAL can be used to ...

  6. A first class constraint generates not a gauge transformation, but a bad physical change: The case of electromagnetism

    Energy Technology Data Exchange (ETDEWEB)

    Pitts, J. Brian, E-mail: jbp25@cam.ac.uk

    2014-12-15

    In Dirac–Bergmann constrained dynamics, a first-class constraint typically does not alone generate a gauge transformation. By direct calculation it is found that each first-class constraint in Maxwell’s theory generates a change in the electric field E{sup →} by an arbitrary gradient, spoiling Gauss’s law. The secondary first-class constraint p{sup i},{sub i}=0 still holds, but being a function of derivatives of momenta (mere auxiliary fields), it is not directly about the observable electric field (a function of derivatives of A{sub μ}), which couples to charge. Only a special combination of the two first-class constraints, the Anderson–Bergmann–Castellani gauge generator G, leaves E{sup →} unchanged. Likewise only that combination leaves the canonical action invariant—an argument independent of observables. If one uses a first-class constraint to generate instead a canonical transformation, one partly strips the canonical coordinates of physical meaning as electromagnetic potentials, vindicating the Anderson–Bergmann Lagrangian orientation of interesting canonical transformations. The need to keep gauge-invariant the relation q-dot −(δH)/(δp) =−E{sub i}−p{sup i}=0 supports using the gauge generator and primary Hamiltonian rather than the separate first-class constraints and the extended Hamiltonian. Partly paralleling Pons’s criticism, it is shown that Dirac’s proof that a first-class primary constraint generates a gauge transformation, by comparing evolutions from identical initial data, cancels out and hence fails to detect the alterations made to the initial state. It also neglects the arbitrary coordinates multiplying the secondary constraints inside the canonical Hamiltonian. Thus the gauge-generating property has been ascribed to the primaries alone, not the primary–secondary team G. Hence the Dirac conjecture about secondary first-class constraints as generating gauge transformations rests upon a false presupposition about

  7. Physical and electromagnetic properties of nanosized Gd substituted Mg–Mn ferrites by solution combustion method

    Energy Technology Data Exchange (ETDEWEB)

    Lwin, Nilar, E-mail: nilarlwin@um.edu.my [Department of Mechanical Engineering, University of Malaya, 50603 Kuala Lumpur (Malaysia); Ahmad Fauzi, M.N.; Sreekantan, Srimala [School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, Engineering Campus, 14300 Nibong Tebal, Penang (Malaysia); Othman, Radzali [Faculty of Manufacturing Engineering, Universiti Teknikal Malaysia Melaka, 76100 Durian Tunggal, Malacca (Malaysia)

    2015-03-15

    Nanosized powders of Gd substituted Mg–Mn ferrites synthesized by solution combustion method using high purity metal nitrates are presented. These powders were calcined, compacted and sintered at 1250 °C. The powders were characterized by X-ray powder diffraction (XRD) and transmission electron microscopy (TEM). The effect of Gd substitution on phase formation, microstructure and bulk density was also studied. Gd{sub 2}O{sub 3} facilitates the formation of a secondary phase on the grain boundary which suppresses abnormal grain growth. The bulk density was found to decrease from 4.26 to 3.38 g/cm{sup 3} with an increase of Gd substitution, but the electrical resistivity was increased. Ferrite with a low dielectric constant in the range of 6–12 was observed and there was no maximum dielectric loss in the frequency range measured to 1 GHz. A decrease in saturation magnetization was also observed by a small fraction of Gd substitution. Correlation between magnetic properties and physical properties were discussed.

  8. 关注电磁学相关物理效应的教学%Paying Close Attention to Teaching of the Physical Effects Related to Electromagnetics

    Institute of Scientific and Technical Information of China (English)

    李长胜; 冯丽爽

    2015-01-01

    We propose to pay close attention to teaching of the physical effects related to electromagnetics in the courses of Theory of Electromagnetic Field and Electromagnetic Field&Wave,and analyze necessity and feasibility of the proposed teaching content. Teaching of electromagnetic effects is of great help to students to let them under-stand basic concepts and theorems of electromagnetic field and wave,to improve their innovation abilities,and to stimulate their interests of study and scientific research. Such factors as different students'majors,dependence on teaching content,and significance in theory and application,play great roles in the selection of electromagnetic effects to teach.%本文提出在“电磁场理论”和“电磁场与电磁波”课程教学中关注电磁学相关物理效应,并分析其必要性和可行性。关注电磁学效应的教学,将有助于学生对电磁场与电磁波相关基本概念和定理的理解,有利于提高学生的创新研究能力,有助于激发学生的学习兴趣和科研热情。在本课程教学过程中,可根据不同专业的需要和教学内容的相关性等,适当选讲具有一定理论和实际意义的电磁学效应。

  9. A three-dimensional mathematical model of electromagnetic casting and testing against a physical model: Part I. The mathematical model

    Science.gov (United States)

    Cook, D. P.; Evans, J. W.

    1995-02-01

    This first of two related articles describes a mathematical model for electromagnetic casting in three dimensions, i.e., where the dependent variables are functions of all three spatial coordinates. It is shown how the method of inductances can be extended to three dimensions in order to solve Maxwell's equations for the electromagnetic field in and around the caster. The principal task here is the calculation of the inductances between loops of irregular shape, and the method by which this is done is described. The computations are self-consistent ones in that the free surface of the molten metal is adjusted in response to the supporting electromagnetic forces which are themselves dependent on the shape of that surface. The computed electromagnetic forces are input into a second phase of the calculation where melt flow is computed in three dimensions using the finite element package FIDAP.

  10. Frozen-shower simulation of electromagnetic showers in the ATLAS forward calorimeter

    CERN Document Server

    Gasnikova, Ksenia; The ATLAS collaboration

    2016-01-01

    Accurate simulation of calorimeter response for high energy electromagnetic particles is essential for the LHC experiments. Detailed simulation of the electromagnetic showers using Geant4 is however very CPU intensive and various fast simulation methods were proposed instead. The frozen shower simulation substitutes the full propagation of the showers for energies below 1~GeV by showers taken from a pre-simulated library. The method is used for production of the main ATLAS Monte Carlo samples, greatly improving the production time. The frozen showers describe shower shapes, sampling fraction, sampling and noise-related fluctuations very well, while description of the constant term, related to calorimeter non-uniformity, requires a careful choice of the shower library binning. A new method is proposed to tune the binning variables, using multivariate techniques. The method is tested and optimized for the description of the ATLAS forward calorimeter.

  11. Simulations of Radioactive Decays: an Application of Low-Energy Electromagnetic Packages for the Nuclear Medicine

    Directory of Open Access Journals (Sweden)

    Munkhbaatar Batmunkh

    2015-12-01

    Full Text Available Problems of the radiobiology and the nuclear medicine require clarifying the specifi cs of radionuclides interactions with unhealthy cells. In this work we aimed to simulate emitting particles tracks of radionuclides and their radioactive decays at DNA level inside the cell nucleus. Accordingly, using the Monte Carlo-based track structure simulation technique, we estimated the radial distribution of deposited energy and kinetic energy spectra of electrons produced by primary particles resulting from radioactive decays of diff erent radionuclides within cell nucleus. To address the possibility of DNA damage, we performed the cluster analysis of track structures of emitted particles inside the volumes corresponding to the size of the native double-stranded DNA. For this purpose, G4-RadioactiveDecay and low- energy electromagnetic packages form Geant4 Monte-Carlo toolkit were combined together. Besides, a comparative analysis was performed for various low-energy electromagnetic packages as G4-DNA and G4-Livermore

  12. Nonlinear surface electromagnetic phenomena

    CERN Document Server

    Ponath, H-E

    1991-01-01

    In recent years the physics of electromagnetic surface phenomena has developed rapidly, evolving into technologies for communications and industry, such as fiber and integrated optics. The variety of phenomena based on electromagnetism at surfaces is rich and this book was written with the aim of summarizing the available knowledge in selected areas of the field. The book contains reviews written by solid state and optical physicists on the nonlinear interaction of electromagnetic waves at and with surfaces and films. Both the physical phenomena and some potential applications are

  13. Biological and Physical Principles and Applications of Electromagnetic Medical Devices%电磁医疗设备的生物物理基础与应用

    Institute of Scientific and Technical Information of China (English)

    包家立

    2016-01-01

    电磁医疗设备是指利用电场、磁场、电磁场实现医疗诊断和治疗的一类仪器、机器或设备。电磁生物效应包括热效应和非热效应,是电磁医疗设备开发的主要理论和审评依据。影响生物效应的物理因素有电磁能量、生物体电容率和磁导率。电磁热效应表现为当温度上升,细胞从无明显损伤、可逆损伤、不可逆损伤、凝固、干燥、碳化或汽化的变化,被应用于高频理疗、微波肿瘤治疗、射频消融、高频电刀等。非热效应是在电磁场暴露下,生物大分子、细胞、组织与器官、整体出现生化和生理反应,而生物体无明显温升,可以应用于心脏起搏、心脏除颤、体外碎石等。近年来,我国在电磁医疗设备领域开展了一些从基础到仪器的研究,开发了一些潜在的电磁医疗设备,如经皮给药电磁导入、经皮给药驻极体、不可逆电穿孔肿瘤治疗等。电磁医疗设备安全控制的有效手段是建立以人体健康为基础的电磁限值标准并执行。%Electromagnetic medical devices refer to a category of equipment used for medical diagnosis and treatment by utilizing electric field, magnetic field, or electromagnetic field. Electromagnetic biological effects including the thermal effects and non-thermal effectsare the main principle and the bases of assessment for innovative electromagnetic medical devices. Physical factors influencing the biological effects include electromagnetic energy as well as permittivity and permeability of organisms. Thermal effects are evidenced by temperature rise. The cells do not suffer from obvious injury, such as the reversible and/or irreversible damage injury caused by the process of coagulation, drying, carbonization or vaporization, which make it able to be applied in high-frequency therapy, microwave tumor therapy, radiofrequency ablation, electric surgery,etc. Non-thermal effects is evidenced

  14. A physical model for low-frequency electromagnetic induction in the near field based on direct interaction between transmitter and receiver electrons

    Science.gov (United States)

    Smith, Ray T.; Jjunju, Fred P. M.; Young, Iain S.; Taylor, Stephen

    2016-01-01

    A physical model of electromagnetic induction is developed which relates directly the forces between electrons in the transmitter and receiver windings of concentric coaxial finite coils in the near-field region. By applying the principle of superposition, the contributions from accelerating electrons in successive current loops are summed, allowing the peak-induced voltage in the receiver to be accurately predicted. Results show good agreement between theory and experiment for various receivers of different radii up to five times that of the transmitter. The limitations of the linear theory of electromagnetic induction are discussed in terms of the non-uniform current distribution caused by the skin effect. In particular, the explanation in terms of electromagnetic energy and Poynting’s theorem is contrasted with a more direct explanation based on variable filament induction across the conductor cross section. As the direct physical model developed herein deals only with forces between discrete current elements, it can be readily adapted to suit different coil geometries and is widely applicable in various fields of research such as near-field communications, antenna design, wireless power transfer, sensor applications and beyond. PMID:27493580

  15. A physical model for low-frequency electromagnetic induction in the near field based on direct interaction between transmitter and receiver electrons

    Science.gov (United States)

    Smith, Ray T.; Jjunju, Fred P. M.; Young, Iain S.; Taylor, Stephen; Maher, Simon

    2016-07-01

    A physical model of electromagnetic induction is developed which relates directly the forces between electrons in the transmitter and receiver windings of concentric coaxial finite coils in the near-field region. By applying the principle of superposition, the contributions from accelerating electrons in successive current loops are summed, allowing the peak-induced voltage in the receiver to be accurately predicted. Results show good agreement between theory and experiment for various receivers of different radii up to five times that of the transmitter. The limitations of the linear theory of electromagnetic induction are discussed in terms of the non-uniform current distribution caused by the skin effect. In particular, the explanation in terms of electromagnetic energy and Poynting's theorem is contrasted with a more direct explanation based on variable filament induction across the conductor cross section. As the direct physical model developed herein deals only with forces between discrete current elements, it can be readily adapted to suit different coil geometries and is widely applicable in various fields of research such as near-field communications, antenna design, wireless power transfer, sensor applications and beyond.

  16. New Vacuum State of the Electromagnetic Field-Matter Coupling System and the Physical Interpretation of Casimir Effect

    Institute of Scientific and Technical Information of China (English)

    李铜忠

    2004-01-01

    A new concise method is presented for the calculation of the ground-state energy of the electromagnetic field and matter field interacting system. With the assumption of squeezed-like state, a new vacuum state is obtained for the interacting system. The energy of the new vacuum state is lower than that given by the second-order perturbation theory in existing theories. In our theory, the Casimir effect is attributed neither to the quantum fluctuation in the zero-point energy of the genuine electromagnetic field nor to that in the zero-point energy of the genuine matter field, but to that in the vacuum state of the interacting system. Both electromagnetic field and matter field are responsible for the Casimir effect.

  17. Development of shashlik electromagnetic calorimeter prototype for SoLID

    Science.gov (United States)

    Shen, C.; Wang, Y.; Xiao, D.; Han, D.; Zou, Z.; Li, Y.; Zheng, X.; Chen, J.

    2017-03-01

    A shashlik electromagnetic calorimeter will be produced in Hall A of Jefferson Laboratory for Solenoidal large Intensity Device (SoLID) to measure the energy deposition of electrons and hadrons, and to provide particle identification after the energy of the accelerator was upgraded to 12 GeV. Tsinghua University is the member of Hall A collaboration in charge of development and production of the large shashlik electromagnetic calorimeter of SoLID. One module of that calorimeter is composed by 194 layers. Each layer consists of a 1.5 mm thick plastic scintillator put on top of a 0.5 mm thick lead plate. Scintillation light is read out by wave-length shifter fibers penetrating through the calorimeter modules longitudinally along the direction of flight of the impact particle. This paper describes the design and construction of that module, as well as a few optimization studies meant to improve its performance. A detailed Geant4 simulation also shows that an energy resolution of 5%/√ E (GeV) and a good containment for electromagnetic showers can be achieved, as well as some basic electron identification. A prototype of that module will be tested soon with an electron beam at JLab.

  18. Computational electromagnetic-aerodynamics

    CERN Document Server

    Shang, Joseph J S

    2016-01-01

    Presents numerical algorithms, procedures, and techniques required to solve engineering problems relating to the interactions between electromagnetic fields, fluid flow, and interdisciplinary technology for aerodynamics, electromagnetics, chemical-physics kinetics, and plasmadynamics This book addresses modeling and simulation science and technology for studying ionized gas phenomena in engineering applications. Computational Electromagnetic-Aerodynamics is organized into ten chapters. Chapter one to three introduce the fundamental concepts of plasmadynamics, chemical-physics of ionization, classical magnetohydrodynamics, and their extensions to plasma-based flow control actuators, high-speed flows of interplanetary re-entry, and ion thrusters in space exploration. Chapter four to six explain numerical algorithms and procedures for solving Maxwell’s equation in the time domain for computational electromagnetics, plasma wave propagation, and the time-dependent c mpressible Navier-Stokes equation for aerodyn...

  19. Electromagnetic reverberation chambers

    CERN Document Server

    Besnier, Philippe

    2013-01-01

    Dedicated to a complete presentation on all aspects of reverberation chambers, this book provides the physical principles behind these test systems in a very progressive manner. The detailed panorama of parameters governing the operation of electromagnetic reverberation chambers details various applications such as radiated immunity, emissivity, and shielding efficiency experiments.In addition, the reader is provided with the elements of electromagnetic theory and statistics required to take full advantage of the basic operational rules of reverberation chambers, including calibration proc

  20. Software and Physics Simulation at Belle II

    CERN Document Server

    Kim, Doris Yangsoo

    2015-01-01

    The Belle II experiment at the SuperKEKB collider in Tsukuba, Japan, will start physics data taking in 2018. It is planned to accumulate an e+ e- collision data set of 50 /ab, about 50 times larger than that of the earlier Belle experiment. The software library for the new detector will use GEANT4 for Monte Carlo simulation and is an entirely new software and reconstruction system based on modern computing tools. Examples of physics simulation including beam background overlays will be described.