WorldWideScience

Sample records for ge medical systems

  1. Interfacial processes in the Pd/a-Ge:H system

    Science.gov (United States)

    Edelman, F.; Cytermann, C.; Brener, R.; Eizenberg, M.; Weil, R.; Beyer, W.

    1993-06-01

    The kinetics of phase transformation has been studied in a two-layer structure of Pd/a-Ge:H after vacuum annealing at temperatures from 180 to 500°C. The a-Ge:H was deposited at 250°C on both c-Si and cleaved NaCl substrates in an RF glow discharge from a GeH 4/H 2 mixture. It was found that, similarly to the Pd/c-Ge and the Pd/a-Ge (e-gun deposited) systems, in the case of 0.15-0.2 μm Pd/0.6-1.0 μm a-Ge:H interfacial germanides formed first through the production of Pd 2Ge (plus a small amount of PdGe), and then PdGe was produced. The growth of both compounds was found to be diffusion-controlled. The nonreacted a-Ge:H layer beneath the germanide overlayer crystallized at 400-500°C. A reverse sequence of germanides formation was revealed in the case of 50 nm Pd/30 nm a-Ge:H, studied by in situ heat treatment in the TEM utilizing non-supported samples. The first germanide detected was PdGe and then, as a result of PdGe and Ge reaction or the PdGe decomposition, Pd 2Ge formed. The temperature dependence of the incubation time before the first ˜ 10 nm PdGe grains formed, followed an Arrhenius curve with an activation energy of 1.45 eV.

  2. Isothermal cross-sections of Sr-Al-Ge and Ba-Al-Ge systems at 673 K

    International Nuclear Information System (INIS)

    Kutsenok, N.L.; Yanson, T.I.

    1987-01-01

    X-ray and microstructural analyses are used to study phase equilibria in Sr-Al-Ge and Ba-Al-Ge systems. Existence of SrAl 2 Ge 2 , Sr(Al, Ge) 2 Ba(Al, Ge) 2 , Sr 3 Al 2 Ge 2 , Ba 3 Al 2 Ge 2 ternary compounds is confirmed, a new BaGe 4 binary compound and also new ternary compounds of approximate composition Sr 57 Al 30 Ge 13 and Ba 20 Al 40 Ge 40 , which crystal structure is unknown, are detected. Aluminium solubility in SrAl 4 and BaAl 4 binary compounds (0.05 atomic fraction) is determined. Ba(Al, Ge) 2 compound homogeneity region is defined more exactly (aluminium content varies from 0.27 to 0.51 at. fractions)

  3. Cognitive Medical Multiagent Systems

    OpenAIRE

    Barna Iantovics

    2010-01-01

    The development of efficient and flexible agent-based medical diagnosis systems represents a recent research direction. Medical multiagent systems may improve the efficiency of traditionally developed medical computational systems, like the medical expert systems. In our previous researches, a novel cooperative medical diagnosis multiagent system called CMDS (Contract Net Based Medical Diagnosis System) was proposed. CMDS system can solve flexibly a large variety of medical diagnosis problems...

  4. Cognitive Medical Multiagent Systems

    Directory of Open Access Journals (Sweden)

    Barna Iantovics

    2010-01-01

    Full Text Available The development of efficient and flexible agent-based medical diagnosis systems represents a recent research direction. Medical multiagent systems may improve the efficiency of traditionally developed medical computational systems, like the medical expert systems. In our previous researches, a novel cooperative medical diagnosis multiagent system called CMDS (Contract Net Based Medical Diagnosis System was proposed. CMDS system can solve flexibly a large variety of medical diagnosis problems. This paper analyses the increased intelligence of the CMDS system, which motivates its use for different medical problem’s solving.

  5. Giant magnetocaloric effect in isostructural MnNiGe-CoNiGe system by establishing a Curie-temperature window

    KAUST Repository

    Liu, E. K.; Zhang, H. G.; Xu, G. Z.; Zhang, X. M.; Ma, R. S.; Wang, W. H.; Chen, J. L.; Zhang, H. W.; Wu, G. H.; Feng, L.; Zhang, Xixiang

    2013-01-01

    An effective scheme of isostructural alloying was applied to establish a Curie-temperature window in isostructural MnNiGe-CoNiGe system. With the simultaneous accomplishment of decreasing structural-transition temperature and converting

  6. Phase diagram of the Ge-rich of the Ba–Ge system and characterisation of single-phase BaGe4

    International Nuclear Information System (INIS)

    Prokofieva, Violetta K.; Pavlova, Lydia M.

    2014-01-01

    Highlights: • The Ba-Ge phase diagram for the range 50–100 at.% Ge was constructed. • Single-phase BaGe 4 grown by the Czochralski method was characterised. • A phenomenological model for a liquid-liquid phase transition is proposed. - Abstract: The Ba–Ge binary system has been investigated by several authors, but some uncertainties remain regarding phases with Ba/Ge ⩽ 2. The goal of this work was to resolve the uncertainty about the current phase diagram of Ba–Ge by performing DTA, X-ray powder diffraction, metallographic and chemical analyses, and measurements of the electrical conductivity and viscosity. The experimental Ba–Ge phase diagram over the composition range of 50–100 at.% Ge was constructed from the cooling curves and single-phase BaGe 4 grown by the Czochralski crystal pulling method was characterised. Semiconducting BaGe 4 crystallised peritectically from the liquid phase near the eutectic. In the liquid state, the caloric effects were observed in the DTA curves at 1050 °C where there are no definite phase lines in the Ba–Ge phase diagram. These effects are confirmed by significant changes in the viscosity and electrical conductivity of a Ba–Ge alloy with eutectic composition at this temperature. A phenomenological model based on two different approaches, a phase approach and a chemical approach, is proposed to explain the isothermal liquid–liquid phase transition observed in the Ba–Ge system from the Ge side. Our results suggest that this transition is due to the peritectic reactions in the liquid phase. This reversible phase transition results in the formation of precursors of various metastable clathrate phases and is associated with sudden changes in the structure of Ba–Ge liquid alloys. Characteristics of both first- and second-order phase transitions are observed. Charge transfer appears to play an important role in this transition

  7. Description of the ternary system Cu-Ge-Te

    International Nuclear Information System (INIS)

    Dogguy, M.; Carcaly, C.; Rivet, J.; Flahaut, J.

    1977-01-01

    The Cu-Ge-Te ternary system has been studied by DTA and by crystallographic and metallographic analysis. The existence of a ternary compound Cu 2 GeTe 3 is demonstrated; this compound has a ternary incongruent melting point at 500 0 C. This ternary compound has a superstructure of a zinc blende type. The study shows the existence of five ternary eutectics. Two liquid-liquid miscibility gaps exist: the first is situated entirely in the ternary system; the second gives a monotectic region within the ternary system. (Auth.)

  8. Reduction in the formation temperature of Poly-SiGe alloy thin film in Si/Ge system

    Science.gov (United States)

    Tah, Twisha; Singh, Ch. Kishan; Madapu, K. K.; Sarguna, R. M.; Magudapathy, P.; Ilango, S.

    2018-04-01

    The role of deposition temperature in the formation of poly-SiGe alloy thin film in Si/Ge system is reported. For the set ofsamples deposited without any intentional heating, initiation of alloying starts upon post annealingat ˜ 500 °C leading to the formation of a-SiGe. Subsequently, poly-SiGe alloy phase could formonly at temperature ≥ 800 °C. Whereas, for the set of samples deposited at 500 °C, in-situ formation of poly-SiGe alloy thin film could be observed. The energetics of the incoming evaporated atoms and theirsubsequent diffusionsin the presence of the supplied thermal energy is discussed to understand possible reasons for lowering of formation temperature/energyof the poly-SiGe phase.

  9. Next Generation, Si-Compatible Materials and Devices in the Si-Ge-Sn System

    Science.gov (United States)

    2015-10-09

    and conclusions The work initially focused on growth of next generation Ge1-ySny alloys on Ge buffered Si wafers via UHV CVD depositions of Ge3H8...Abstract The work initially focused on growth of next generation Ge1-ySny alloys on Ge buffered Si wafers via UHV CVD depositions of Ge3H8, SnD4. The...AFRL-AFOSR-VA-TR-2016-0044 Next generation, Si -compatible materials and devices in the Si - Ge -Sn system John Kouvetakis ARIZONA STATE UNIVERSITY Final

  10. Medical imaging systems

    Science.gov (United States)

    Frangioni, John V

    2013-06-25

    A medical imaging system provides simultaneous rendering of visible light and diagnostic or functional images. The system may be portable, and may include adapters for connecting various light sources and cameras in open surgical environments or laparascopic or endoscopic environments. A user interface provides control over the functionality of the integrated imaging system. In one embodiment, the system provides a tool for surgical pathology.

  11. Medical Imaging System

    Science.gov (United States)

    1991-01-01

    The MD Image System, a true-color image processing system that serves as a diagnostic aid and tool for storage and distribution of images, was developed by Medical Image Management Systems, Huntsville, AL, as a "spinoff from a spinoff." The original spinoff, Geostar 8800, developed by Crystal Image Technologies, Huntsville, incorporates advanced UNIX versions of ELAS (developed by NASA's Earth Resources Laboratory for analysis of Landsat images) for general purpose image processing. The MD Image System is an application of this technology to a medical system that aids in the diagnosis of cancer, and can accept, store and analyze images from other sources such as Magnetic Resonance Imaging.

  12. A Waveform Archiving System for the GE Solar 8000i Bedside Monitor.

    Science.gov (United States)

    Fanelli, Andrea; Jaishankar, Rohan; Filippidis, Aristotelis; Holsapple, James; Heldt, Thomas

    2018-01-01

    Our objective was to develop, deploy, and test a data-acquisition system for the reliable and robust archiving of high-resolution physiological waveform data from a variety of bedside monitoring devices, including the GE Solar 8000i patient monitor, and for the logging of ancillary clinical and demographic information. The data-acquisition system consists of a computer-based archiving unit and a GE Tram Rac 4A that connects to the GE Solar 8000i monitor. Standard physiological front-end sensors connect directly to the Tram Rac, which serves as a port replicator for the GE monitor and provides access to these waveform signals through an analog data interface. Together with the GE monitoring data streams, we simultaneously collect the cerebral blood flow velocity envelope from a transcranial Doppler ultrasound system and a non-invasive arterial blood pressure waveform along a common time axis. All waveform signals are digitized and archived through a LabView-controlled interface that also allows for the logging of relevant meta-data such as clinical and patient demographic information. The acquisition system was certified for hospital use by the clinical engineering team at Boston Medical Center, Boston, MA, USA. Over a 12-month period, we collected 57 datasets from 11 neuro-ICU patients. The system provided reliable and failure-free waveform archiving. We measured an average temporal drift between waveforms from different monitoring devices of 1 ms every 66 min of recorded data. The waveform acquisition system allows for robust real-time data acquisition, processing, and archiving of waveforms. The temporal drift between waveforms archived from different devices is entirely negligible, even for long-term recording.

  13. Exploration Medical System Demonstration

    Science.gov (United States)

    Rubin, D. A.; Watkins, S. D.

    2014-01-01

    BACKGROUND: Exploration class missions will present significant new challenges and hazards to the health of the astronauts. Regardless of the intended destination, beyond low Earth orbit a greater degree of crew autonomy will be required to diagnose medical conditions, develop treatment plans, and implement procedures due to limited communications with ground-based personnel. SCOPE: The Exploration Medical System Demonstration (EMSD) project will act as a test bed on the International Space Station (ISS) to demonstrate to crew and ground personnel that an end-to-end medical system can assist clinician and non-clinician crew members in optimizing medical care delivery and data management during an exploration mission. Challenges facing exploration mission medical care include limited resources, inability to evacuate to Earth during many mission phases, and potential rendering of medical care by non-clinicians. This system demonstrates the integration of medical devices and informatics tools for managing evidence and decision making and can be designed to assist crewmembers in nominal, non-emergent situations and in emergent situations when they may be suffering from performance decrements due to environmental, physiological or other factors. PROJECT OBJECTIVES: The objectives of the EMSD project are to: a. Reduce or eliminate the time required of an on-orbit crew and ground personnel to access, transfer, and manipulate medical data. b. Demonstrate that the on-orbit crew has the ability to access medical data/information via an intuitive and crew-friendly solution to aid in the treatment of a medical condition. c. Develop a common data management framework that can be ubiquitously used to automate repetitive data collection, management, and communications tasks for all activities pertaining to crew health and life sciences. d. Ensure crew access to medical data during periods of restricted ground communication. e. Develop a common data management framework that

  14. The Ho–Ni–Ge system: Isothermal section and new rare-earth nickel germanides

    Energy Technology Data Exchange (ETDEWEB)

    Morozkin, A.V., E-mail: morozkin@tech.chem.msu.ru [Department of Chemistry, Moscow State University, Leninskie Gory, House 1, Building 3, GSP-2, Moscow 119992 (Russian Federation); Knotko, A.V. [Department of Chemistry, Moscow State University, Leninskie Gory, House 1, Building 3, GSP-2, Moscow 119992 (Russian Federation); Yapaskurt, V.O. [Department of Petrology, Faculty of Geology, Moscow State University, Leninskie Gory, Moscow 119992 (Russian Federation); Yuan, Fang; Mozharivskyj, Y. [Department of Chemistry and Chemical Biology, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4M1 (Canada); Pani, M.; Provino, A.; Manfrinetti, P. [Institute SPIN-CNR and Dipartimento di Chimica e Chimica Industriale, Università di Genova, Via Dodecaneso 31, 16146 Genova (Italy)

    2015-05-15

    The Ho–Ni–Ge system has been investigated at 1070 K and up to ~60 at% Ho by X-ray diffraction and microprobe analyses. Besides the eight known compounds, HoNi{sub 5}Ge{sub 3} (YNi{sub 5}Si{sub 3}-type), HoNi{sub 2}Ge{sub 2} (CeAl{sub 2}Ga{sub 2}-type), Ho{sub 2}NiGe{sub 6} (Ce{sub 2}CuGe{sub 6}-type), HoNiGe{sub 3} (SmNiGe{sub 3}-type), HoNi{sub 0.2÷0.6}Ge{sub 2} (CeNiSi{sub 2}-type), Ho{sub 37÷34}Ni{sub 6÷24}Ge{sub 57÷42} (AlB{sub 2}-type), HoNiGe (TiNiSi-type), Ho{sub 3}NiGe{sub 2} (La{sub 3}NiGe{sub 2}-type), the ternary system contains four new compounds: Ho{sub 3}Ni{sub 11}Ge{sub 4} (Sc{sub 3}Ni{sub 11}Ge{sub 4}-type), HoNi{sub 3}Ge{sub 2} (ErNi{sub 3}Ge{sub 2}-type), Ho{sub 3}Ni{sub 2}Ge{sub 3} (Hf{sub 3}Ni{sub 2}Si{sub 3}-type) and ~Ho{sub 5}Ni{sub 2}Ge{sub 3} (unknown structure). Quasi-binary solid solutions were observed at 1070 K for Ho{sub 2}Ni{sub 17}, HoNi{sub 5}, HoNi{sub 7}, HoNi{sub 3}, HoNi{sub 2}, HoNi and Ho{sub 2}Ge{sub 3}, but no detectable solubility was found for the other binary compounds in the Ho–Ni–Ge system. Based on the magnetization measurements, the HoNi{sub 5}Ge{sub 3}, HoNi{sub 3}Ge{sub 2} and Ho{sub 3}Ni{sub 11}Ge{sub 4} (and isostructural (Tb, Dy){sub 3}Ni{sub 11}Ge{sub 4}) compounds have been found to show paramagnetic behavior down to 5 K, whereas Ho{sub 3}Ni{sub 2}Ge{sub 3} exhibits an antiferromagnetic transition at ~7 K. Additionally, the crystal structure of the new isostructural phases (Y, Yb)Ni{sub 3}Ge{sub 2} (ErNi{sub 3}Ge{sub 2}-type), Er{sub 3}Ni{sub 11}Ge{sub 4} (Sc{sub 3}Ni{sub 11}Ge{sub 4}-type) and (Y, Tb, Dy, Er, Tm){sub 3}Ni{sub 2}Ge{sub 3} (Hf{sub 3}Ni{sub 2}Si{sub 3}-type) has been also investigated. - Graphical abstract: The Ho–Ni–Ge system has been investigated at 1070 K and up to ~60 at.% Ho by X-ray and microprobe analyses. Besides the eight known compounds, i.e. HoNi{sub 5}Ge{sub 3} (YNi{sub 5}Si{sub 3}-type), HoNi{sub 2}Ge{sub 2} (CeAl{sub 2}Ga{sub 2}-type), Ho{sub 2}NiGe{sub 6} (Ce{sub 2

  15. Giant magnetocaloric effect in isostructural MnNiGe-CoNiGe system by establishing a Curie-temperature window

    KAUST Repository

    Liu, E. K.

    2013-03-28

    An effective scheme of isostructural alloying was applied to establish a Curie-temperature window in isostructural MnNiGe-CoNiGe system. With the simultaneous accomplishment of decreasing structural-transition temperature and converting antiferromagnetic martensite to ferromagnetic state, a 200 K Curie-temperature window was established between Curie temperatures of austenite and martensite phases. In the window, a first-order magnetostructural transition between paramagnetic austenite and ferromagnetic martensite occurs with a sharp jump in magnetization, showing a magnetic entropy change as large as −40 J kg−1 K−1 in a 50 kOe field change. This giant magnetocaloric effect enables Mn1− x Co x NiGe to become a potential magnetic refrigerant.

  16. Medical imaging systems

    Science.gov (United States)

    Frangioni, John V [Wayland, MA

    2012-07-24

    A medical imaging system provides simultaneous rendering of visible light and fluorescent images. The system may employ dyes in a small-molecule form that remains in a subject's blood stream for several minutes, allowing real-time imaging of the subject's circulatory system superimposed upon a conventional, visible light image of the subject. The system may also employ dyes or other fluorescent substances associated with antibodies, antibody fragments, or ligands that accumulate within a region of diagnostic significance. In one embodiment, the system provides an excitation light source to excite the fluorescent substance and a visible light source for general illumination within the same optical guide that is used to capture images. In another embodiment, the system is configured for use in open surgical procedures by providing an operating area that is closed to ambient light. More broadly, the systems described herein may be used in imaging applications where a visible light image may be usefully supplemented by an image formed from fluorescent emissions from a fluorescent substance that marks areas of functional interest.

  17. The Low Temperature Epitaxy of Strained GeSn Layers Using RTCVD System

    Science.gov (United States)

    Kil, Yeon-Ho; Yuk, Sim-Hoon; Jang, Han-Soo; Lee, Sang-Geul; Choi, Chel-Jong; Shim, Kyu-Hwan

    2018-03-01

    We have investigated the low temperature (LT) growth of GeSn-Ge-Si structures using rapid thermal chemical vapor deposition system utilizing Ge2H6 and SnCl4 as the reactive precursors. Due to inappropriate phenomena, such as, Ge etch and Sn segregation, it was hard to achieve high quality GeSn epitaxy at the temperature > 350 °C. On the contrary, we found that the SnCl4 promoted the reaction of Ge2H6 precursors in a certain process condition of LT, 240-360 °C. In return, we could perform the growth of GeSn epi layer with 7.7% of Sn and its remaining compressive strain of 71.7%. The surface propagated defects were increased with increasing the Sn content in the GeSn layer confirmed by TEM analysis. And we could calculate the activation energies at lower GeSn growth temperature regime using by Ge2H6 and SnCl4 precursors about 0.43 eV.

  18. Medical Certification System -

    Data.gov (United States)

    Department of Transportation — Provides automated risk-based decision making capability in support of medical certification and clearances processing associated fees and supporting surveillance of...

  19. Static structure of superionic conducting glass of Ag-Ge-Se system

    Energy Technology Data Exchange (ETDEWEB)

    Suenaga, R; Nakashima, S; Tahara, S; Takeda, S [Graduate School of Sciences, Kyushu University, 4-2-1 Ropponmatsu, Fukuoka 810-8560 (Japan); Kawakita, Y [Faculty of Sciences, Kyushu University, 4-2-1 Ropponmatsu, Fukuoka 810-8560 (Japan); Kohara, S [Japan Synchrotron Radiation Research Inst., 1-1-1 Kouto, Sayo-cho, Hyogo 679-5198 (Japan)], E-mail: takeda@rc.kyushu-u.ac.jp

    2008-02-15

    Superionic conducting glasses are the important materials as solid electrolytes. Amorphous Ag-Ge-Se system is well known to exhibit the superionic conducting behavior where silver ions easily migrate into the mixed structure of Ag{sub 2}Se and Ge-Se chalcogenide glass. It will be good material to study how the superionic conducting region distributes in the glassy network, and whether the conducting paths extends to the entire of the material, or the localized and limited area in an isolated region. In this paper, we will present the results of the static structure of Ag-Ge-Se system by high-energy X-ray diffraction measurements.

  20. Exploration Medical System Demonstration Project

    Science.gov (United States)

    Chin, D. A.; McGrath, T. L.; Reyna, B.; Watkins, S. D.

    2011-01-01

    A near-Earth Asteroid (NEA) mission will present significant new challenges including hazards to crew health created by exploring a beyond low earth orbit destination, traversing the terrain of asteroid surfaces, and the effects of variable gravity environments. Limited communications with ground-based personnel for diagnosis and consultation of medical events require increased crew autonomy when diagnosing conditions, creating treatment plans, and executing procedures. Scope: The Exploration Medical System Demonstration (EMSD) project will be a test bed on the International Space Station (ISS) to show an end-to-end medical system assisting the Crew Medical Officers (CMO) in optimizing medical care delivery and medical data management during a mission. NEA medical care challenges include resource and resupply constraints limiting the extent to which medical conditions can be treated, inability to evacuate to Earth during many mission phases, and rendering of medical care by a non-clinician. The system demonstrates the integration of medical technologies and medical informatics tools for managing evidence and decision making. Project Objectives: The objectives of the EMSD project are to: a) Reduce and possibly eliminate the time required for a crewmember and ground personnel to manage medical data from one application to another. b) Demonstrate crewmember's ability to access medical data/information via a software solution to assist/aid in the treatment of a medical condition. c) Develop a common data management architecture that can be ubiquitously used to automate repetitive data collection, management, and communications tasks for all crew health and life sciences activities. d) Develop a common data management architecture that allows for scalability, extensibility, and interoperability of data sources and data users. e) Lower total cost of ownership for development and sustainment of peripheral hardware and software that use EMSD for data management f) Provide

  1. Enhanced Emission of Quantum System in Si-Ge Nanolayer Structure.

    Science.gov (United States)

    Huang, Zhong-Mei; Huang, Wei-Qi; Dong, Tai-Ge; Wang, Gang; Wu, Xue-Ke

    2016-12-01

    It is very interesting that the enhanced peaks near 1150 and 1550 nm are observed in the photoluminescence (PL) spectra in the quantum system of Si-Ge nanolayer structure, which have the emission characteristics of a three-level system with quantum dots (QDs) pumping and emission of quasi-direct-gap band, in our experiment. In the preparing process of Si-Ge nanolayer structure by using a pulsed laser deposition method, it is discovered that the nanocrystals of Si and Ge grow in the (100) and (111) directions after annealing or electron beam irradiation. The enhanced PL peaks with multi-longitudinal-mode are measured at room temperature in the super-lattice of Si-Ge nanolayer quantum system on SOI.

  2. Communication system and spectral analysis for Ge-Li and GeHp detectors

    International Nuclear Information System (INIS)

    Fernandez, J.; Castano, P.; Bonino, A.D.; Righetti, M.A.

    1990-01-01

    An integral communication and spectral analysis system (SICADE) was developed and implemented to satisfy the need to optimize and automate the measurement system used in Atucha I nuclear power plant for the activity in the primary loop's water extracted by the TV system. The importance of these measurements is based on the fact that from the spectrometric analysis of the samples extracted, the Iodines-GN and Iodines-Iodines relations, which allow to detect the presence of deficient fuel elements, are calculated. The system developed is based on two modules integrated in a unique set commanded by the operators through the screen dialogue. (Author) [es

  3. Medical Expert Systems Survey

    OpenAIRE

    Abu-Nasser, Bassem S.

    2017-01-01

    International audience; There is an increased interest in the area of Artificial Intelligence in general and expert systems in particular. Expert systems are rapidly growing technology. Expert systems are a branch of Artificial Intelligence which is having a great impact on many fields of human life. Expert systems use human expert knowledge to solve complex problems in many fields such as Health, science, engineering, business, and weather forecasting. Organizations employing the technology ...

  4. BRAIN Journal - Cognitive Medical Multiagent Systems

    OpenAIRE

    Barna Iantovics

    2017-01-01

    Abstract The development of efficient and flexible agent-based medical diagnosis systems represents a recent research direction. Medical multiagent systems may improve the efficiency of traditionally developed medical computational systems, like the medical expert systems. In our previous researches, a novel cooperative medical diagnosis multiagent system called CMDS (Contract Net Based Medical Diagnosis System) was proposed. CMDS system can solve flexibly a large variety of medical diagn...

  5. Thermodynamic modeling of the Ge-Ti system supported by key experiment

    International Nuclear Information System (INIS)

    Liu, Dandan; Yan, Huanli; Yuan, Xiaoming; Chung, Yoonsung; Du, Yong; Xu, Honghui; Liu, Libin; Nash, Philip

    2011-01-01

    Highlights: → All of the experimental phase diagram and thermodynamic data available for the Ge-Ti system have been critically evaluated. → The general feature of the Ge-Ti system and enthalpy of formation of Ti 5 Ge 3 have been checked via experiment. The annealed samples are characterized by X-ray diffraction, scanning electron microscope and differential thermal analysis. → An optimum thermodynamic data set for the Ge-Ti system was obtained. The comprehensive comparison shows that the calculated phase diagram and thermodynamic properties are in good agreement with the experimental data. - Abstract: A complete thermodynamic investigation of the Ge-Ti system was performed in this study. Seven samples were prepared by arc-melting the pure elements in order to check the literature data on phase diagram and enthalpy of formation of Ti 5 Ge 3 . The samples were annealed at certain temperatures for extended periods of time, and then quenched. Both the as-cast and annealed samples were examined by X-ray diffraction (XRD) analysis and scanning electron microscope (SEM) technology. The phase transformation temperatures were measured by differential thermal analysis (DTA). The measurement on enthalpy of formation for Ti 5 Ge 3 was performed using the Kleppa-type HTRC with the calorimeter temperature set at 1100 ± 2 o C. Based upon the literature data and current experimental results, the Ge-Ti system was critically assessed by means of CALPHAD approach. The calculated phase diagram and thermodynamic properties agree well with the literature data and the present experimental results.

  6. Photo- and Thermo-Induced Changes in Optical Constants and Structure of Thin Films from GeSe2-GeTe-ZnTe System

    Science.gov (United States)

    Petkov, Kiril; Todorov, Rossen; Vassilev, Venceslav; Aljihmani, Lilia

    We examined the condition of preparation of thin films from GeSe2-GeTe-ZnTe system by thermal evaporation and changes in their optical properties after exposure to light and thermal annealing. The results for composition analysis of thin films showed absence of Zn independently of the composition of the bulk glass. By X-ray diffraction (XRD) analysis it was found that a reduction of ZnTe in ZnSe in bulk materials takes of place during the film deposition. A residual from ZnSe was observed in the boat after thin film deposition. Optical constants (refractive index, n and absorption coefficient, α) and thickness, d as well as the optical band gap, Eg, depending of the content of Te in ternary Ge-Se-Te system are determined from specrophotometric measurements in the spectral range 400-2500 nm applying the Swanepoel's envelope method and Tauc's procedure. With the increase of Te content in the layers the absorption edge is shifted to the longer wavelengths, refractive index increases while the optical band gap decreases from 2.02 eV for GeSe2 to 1.26 eV for Ge34Se42Te24. The values of the refractive index decrease after annealing of all composition and Eg increase, respectively. Thin films with composition of Ge27Se47Te9Zn17 and Ge28Se49Te10Zn13 were prepared by co-evaporation of (GeSe2)78(GeTe)22 and Zn from a boat and a crucible and their optical properties, surface morphology and structure were investigated. The existence of a correlation between the optical band gap and the copostion of thin films from the system studied was demonstrated.

  7. Medical Information Management System

    Science.gov (United States)

    Alterescu, S.; Hipkins, K. R.; Friedman, C. A.

    1979-01-01

    On-line interactive information processing system easily and rapidly handles all aspects of data management related to patient care. General purpose system is flexible enough to be applied to other data management situations found in areas such as occupational safety data, judicial information, or personnel records.

  8. Electric utility system benefits of factory packaged GE LM Modular Generator sets

    Energy Technology Data Exchange (ETDEWEB)

    West, G.

    1994-12-31

    Electric utility system benefits of factory packaged GE LM modular generator sets are outlined. The following topics are discussed: GE LM gas turbine history, operating experience, maintenance, gas turbine spare engines, modular gas turbine generator sets, typical LM2500 cogeneration plant and STIG cycle plant, factory packaging concept, gas turbine/generator package, performance, comparison, competitive capital cost, phased construction, comparison of revenue requirements, capacity evaluation, heat rate evaluation, fuel evaluation, startup, and dispatch flexibility without maintenance penalty.

  9. Medical-Information-Management System

    Science.gov (United States)

    Alterescu, Sidney; Friedman, Carl A.; Frankowski, James W.

    1989-01-01

    Medical Information Management System (MIMS) computer program interactive, general-purpose software system for storage and retrieval of information. Offers immediate assistance where manipulation of large data bases required. User quickly and efficiently extracts, displays, and analyzes data. Used in management of medical data and handling all aspects of data related to care of patients. Other applications include management of data on occupational safety in public and private sectors, handling judicial information, systemizing purchasing and procurement systems, and analyses of cost structures of organizations. Written in Microsoft FORTRAN 77.

  10. Processing and characterization of new oxysulfide glasses in the Ge-Ga-As-S-O system

    International Nuclear Information System (INIS)

    Maurel, C.; Petit, L.; Dussauze, M.; Kamitsos, E.I.; Couzi, M.; Cardinal, T.; Miller, A.C.; Jain, H.; Richardson, K.

    2008-01-01

    New oxysulfide glasses have been prepared in the Ge-Ga-As system employing a two-step melting process which involves the processing of the chalcogenide glass (ChG) and its subsequent melting with amorphous GeO 2 powder. Optical characterization of the synthesized oxysulfide glasses has shown that the cut-off wavelength decreases with increasing oxygen content, and this has been correlated to results of Raman and infrared (IR) spectroscopies which show the formation of new oxysulfide structural units. X-ray photoelectron spectroscopy (XPS) analysis to probe the bonding environment of oxygen atoms in the oxysulfide glass network, has revealed the preferred formation of Ga-O and Ge-O bonds in comparison to As-O bonds. This work has demonstrated that melting a ChG glass with GeO 2 leads to the formation of new oxysulfide glassy materials. - Graphical abstract: In this paper, we explain how new oxysulfide glasses are prepared in the Ge-Ga-As system employing a two-step process: (1) the processing of the chalcogenide glass (ChG) and (2) the re-melting of the ChG with GeO 2 powder. Raman, infrared and XPS spectroscopies show the formation of new oxysulfide structural units

  11. Comprehensive thermodynamic description of the quasiternary system PbTe-GeTe-SnTe

    International Nuclear Information System (INIS)

    Yashina, Lada V.; Leute, Volkmar; Shtanov, Vladimir I.; Schmidtke, Heinrich M.; Neudachina, Vera S.

    2006-01-01

    The equilibrium phase diagram of the quasiternary system PbTe-GeTe-SnTe was studied experimentally in the ranges of spinodal demixing and (solid + liquid) equilibrium by means of X-ray diffraction (XRD), electron microprobe analysis (EMA) and differential thermal analysis (DTA). A model description of the phase diagram was done on the base of composition dependent interaction parameters, which were determined for the solid and the liquid phases. The interaction parameters for the quasibinary systems were recalculated in order to reach better correlation between all experimental data. It was shown that the quasiternary phase diagram can be principally described using the interaction parameters for the quasibinary subsystems, but an additional ternary interaction parameter has also to be considered. The local structure of the quasiternary solid solution is described by a four-particle cluster model. Due to the tendency of the solid solution to demix, the probability of the (GeGeGe)Te cluster was found to be higher and that of the (PbGeGe)Te cluster to be lower than it is expected for the purely statistical distribution of the clusters

  12. Sc-W-Si and Sc-W-Ge ternary systems

    International Nuclear Information System (INIS)

    Kotur, B.Ya.; Voznyak, O.M.; Bodak, O.I.

    1989-01-01

    Phase equilibria in Sc-W-Si and Sc-W-Ge ternary systems are investigated at 1070 K. Sc 2+x W 3-x Si 4 ternary compound (0≤x≤1) is determined, its crystal structure (Ce 2 Sc 3 Si 4 structural type), as well as, change of elementary cell parameters and microhardness within homogeneity range are determined. Regularities of component interaction within Sc-M-Si(Ge) (M-Cr, Mo, W) ternary system are determined. Ternary systems with Mo and W are more closer to each other according to the phase equilibria character, than to ternary systems with Cr

  13. Thermodynamic description of the C-Ge and C-Mg systems

    Directory of Open Access Journals (Sweden)

    Hu B.

    2010-01-01

    Full Text Available The thermodynamic modeling for the C-Ge and C-Mg systems is performed by the CALPHAD method. The enthalpy of formation for Mg2C3, the experimental value of which is not available in the literature, is obtained via first-principles calculation to refine the thermodynamic modeling of the C-Mg system. A comparison of the thermodynamic calculations with the available literature data shows that the presently obtained two sets of thermodynamic parameters for the C-Ge and C-Mg systems can well describe the these two systems.

  14. Isothermal sections of the state diagram for the Pr-Ni-Ge system at 870 (0-0,5Pr) and 670 K (0,5-1Pr)

    International Nuclear Information System (INIS)

    Fedyna, M.F.; Pecharskij, V.K.; Bodak, O.I.

    1987-01-01

    Method of X-ray phase and microstructural analyses were used to study Pr-Ni-Ge ternary system at 870K (0-0.50 at.fractions of Pr) and 670K (0.50-1.00 at.fractions of Pr). 11 ternary compounds exist in the system: Pr 1-x (NiGe) 13 (x=0.24), PrNi 2 Ge 2 , Pr 2 Ni 3 Ge 5 , PrNiGe 3 , Pr 2 NiGe 6 , Pr 3 Ni 4 Ge 4 , PrNi (1-x) Ge 2 (x=0.33), PrNiGe, Pr(NiGe) 2-x (x=0.14), Pr 3 NiGe 2 , ∼Pr 5 NiGe 4 . Crystal structure was determined for seven ternary compounds

  15. Improvements on monitor system in the KEK 2.5-GeV linac

    International Nuclear Information System (INIS)

    Shidara, T.; Oogoe, T.; Ogawa, Y.

    1989-01-01

    Improvements to the monitor system of the KEK 2.5-GeV linac have been undertaken. Energy analyzing stations were added to both the positron generator linac and the 2.5-GeV electron linac in order to realize easier checking of beam energy. Wall current monitors and profile monitors were added in the beam transport line between the positron generator linac and the 2.5-GeV electron linac in order to realize easier positron-beam transfer. As a result of the installation of an automatic beam-current-surveillance system and with other existing surveillance systems, more reliable and easier operation of the linac is expected. (author)

  16. GE`s worldwide experience with IFO based gypsum producing flue gas desulfurization systems

    Energy Technology Data Exchange (ETDEWEB)

    Saleem, A. [GE Environmental Systems, Lebanon, PA (United States)

    1994-12-31

    The In-Situ Forced Oxidation (IFO) process to produce gypsum in a commercial scale flue gas desulfurization (FGD) system was first demonstrated by GE Environmental Systems in 1980 at the Monticello Generating Station of Texas Utilities. Since then, the IFO technology developed and demonstrated by GE has become the industry standard and is used extensively on a world-wide basis to produce both commercial and disposable-grade gypsum. The paper gives an overview of the development, demonstration, commercial design and current status of the IFO technology.

  17. Determination of a new structure type in the Sc-Fe-Ge-Sn system

    Energy Technology Data Exchange (ETDEWEB)

    Brgoch, Jakoah [Department of Chemistry, Iowa State University, Ames, IA 50011 (United States); Ran, Sheng [Ames Laboratory, US Department of Energy, Ames, IA 50011 (United States); Department of Physics and Astronomy, Iowa State University, Ames, IA 50011 (United States); Thimmaiah, Srinivasa [Department of Chemistry, Iowa State University, Ames, IA 50011 (United States); Ames Laboratory, US Department of Energy, Ames, IA 50011 (United States); Canfield, Paul C. [Ames Laboratory, US Department of Energy, Ames, IA 50011 (United States); Department of Physics and Astronomy, Iowa State University, Ames, IA 50011 (United States); Miller, Gordon J., E-mail: gmiller@iastate.edu [Department of Chemistry, Iowa State University, Ames, IA 50011 (United States); Ames Laboratory, US Department of Energy, Ames, IA 50011 (United States)

    2013-01-05

    Highlights: Black-Right-Pointing-Pointer A new structure type with the composition Sc{sub 4}Fe{sub 5}Ge{sub 6.10(3)}Sn{sub 1.47(2)}. Black-Right-Pointing-Pointer Crystallizes in the space group Immm (No. 71, oI144). Black-Right-Pointing-Pointer Sample obtained using a reactive Sn flux. Black-Right-Pointing-Pointer Electronic structure calculations indicate polar intermetallic bonding network. - Abstract: A new structure type has been discovered in the system Sc-Fe-Ge-Sn by employing Sn as a flux medium. According to single crystal X-ray diffraction, the new structure has a composition of Sc{sub 4}Fe{sub 5}Ge{sub 6.10(3)}Sn{sub 1.47(2)} and crystallizes in the space group Immm (No. 71, oI144) with lattice parameters of a = 5.230(1) A, b = 13.467(3) A, and c = 30.003(6) A. The structure is composed of square anti-prismatic clusters that are condensed into zig-zag chains along the [0 1 0] direction. These chains are further condensed through a split Sn/Ge position, forming a three-dimensional network. Magnetization measurements indicate an antiferromagnetic phase transition near 240 K. Electronic structure calculations identified the most favorable bonding network in this new system. Using crystal orbital Hamilton population (COHP) curves and their integrated values (ICOHP), a polar intermetallic bonding network involving Sc-Ge as well as Fe-Sn and Fe-Ge contacts can be assigned to this new structure type.

  18. Medical Archive Recording System (MARS)

    OpenAIRE

    Mohammad Reza Tajvidi

    2007-01-01

    In this talk, one of the most efficient, and reliable integrated tools for CD/DVD production workflow, called Medical Archive Recording System (MARS) by ETIAM Company, France, which is a leader in multimedia connectivity for healthcare in Europe, is going to be introduced. "nThis tool is used to record all patient studies, route the studies to printers and PACS automatically, print key images and associated reports and log all study production for automated post processing/archiving. Its...

  19. Stereoscopic medical imaging collaboration system

    Science.gov (United States)

    Okuyama, Fumio; Hirano, Takenori; Nakabayasi, Yuusuke; Minoura, Hirohito; Tsuruoka, Shinji

    2007-02-01

    The computerization of the clinical record and the realization of the multimedia have brought improvement of the medical service in medical facilities. It is very important for the patients to obtain comprehensible informed consent. Therefore, the doctor should plainly explain the purpose and the content of the diagnoses and treatments for the patient. We propose and design a Telemedicine Imaging Collaboration System which presents a three dimensional medical image as X-ray CT, MRI with stereoscopic image by using virtual common information space and operating the image from a remote location. This system is composed of two personal computers, two 15 inches stereoscopic parallax barrier type LCD display (LL-151D, Sharp), one 1Gbps router and 1000base LAN cables. The software is composed of a DICOM format data transfer program, an operation program of the images, the communication program between two personal computers and a real time rendering program. Two identical images of 512×768 pixcels are displayed on two stereoscopic LCD display, and both images show an expansion, reduction by mouse operation. This system can offer a comprehensible three-dimensional image of the diseased part. Therefore, the doctor and the patient can easily understand it, depending on their needs.

  20. Investigation of the phase relations in the U-Al-Ge ternary system: Influence of the Al/Ge substitution on the properties of the intermediate phases

    Energy Technology Data Exchange (ETDEWEB)

    Moussa, C.; El Sayah, Z. [Institut des Sciences Chimiques de Rennes, Chimie du Solide et Matériaux, UMR CNRS 6226, Université Rennes 1, Campus de Beaulieu, 35042 Rennes Cedex (France); Chajewski, G. [Institute of Low Temperature and Structure Research, Polish Academy of Sciences, ul. Okólna 2, 50-422 Wrocław (Poland); Berche, A.; Dorcet, V. [Institut des Sciences Chimiques de Rennes, Chimie du Solide et Matériaux, UMR CNRS 6226, Université Rennes 1, Campus de Beaulieu, 35042 Rennes Cedex (France); Pikul, A.P. [Institute of Low Temperature and Structure Research, Polish Academy of Sciences, ul. Okólna 2, 50-422 Wrocław (Poland); Pasturel, M. [Institut des Sciences Chimiques de Rennes, Chimie du Solide et Matériaux, UMR CNRS 6226, Université Rennes 1, Campus de Beaulieu, 35042 Rennes Cedex (France); Joanny, L. [ScanMAT – CMEBA, University of Rennes 1, Campus de Beaulieu, 35042 Rennes Cedex (France); Stepnik, B. [AREVA/CERCA, 10 Rue Juliette Récamier, 69006 Lyon (France); Tougait, O., E-mail: tougait@univ-rennes1.fr [Institut des Sciences Chimiques de Rennes, Chimie du Solide et Matériaux, UMR CNRS 6226, Université Rennes 1, Campus de Beaulieu, 35042 Rennes Cedex (France); Unité de Catalyse et de Chimie du Solide, UMR CNRS 8181, Université de Lille, 59695 Villeneuve d' Ascq (France)

    2016-11-15

    The phase relations within the U-Al-Ge ternary system were studied for two isothermal sections, at 673 K for the whole Gibbs triangle and at 1173 K for the concentration range 25–100 at% U. The identification of the phases, their composition ranges and stability were determined by x-ray powder diffraction, scanning electron microscopy coupled to energy dispersive spectroscopy and differential thermal analysis. The tie-lines and the solubility domains were determined for the U-Ge and U-Al binaries, the UAl{sub 3}-UGe{sub 3} solid-solution and for the unique ternary intermediate phase U{sub 3}Al{sub 2−x}Ge{sub 3+x}. The experimental isopleth section of the pseudo-binary UAl{sub 3}-UGe{sub 3} reveals an isomorphous solid solution based on the Cu{sub 3}Au-type below the solidus. The U{sub 3}Al{sub 2−x}Ge{sub 3+x} solid solution extends for −0.1≤x≤1.35 and −0.2≤x≤1.5 at 673 K and 1173 K respectively. It crystallizes in the I-centered tetragonal symmetry. The reciprocal lattice of several compositions of the U{sub 3}Al{sub 2−x}Ge{sub 3+x} solid solution was examined by electron diffraction at room temperature, revealing the presence of a c-glide plane. Their crystal structure was refined by single crystal x-ray diffraction suggesting an isomorphous solid solution best described with the non-centrosymmetric space group I4cm in the paramagnetic domain. The magnetic measurements confirm the ferromagnetic ordering of the solid solution U{sub 3}Al{sub 2−x}Ge{sub 3+x} with an increase of Tc with the Al content. The thermal variation of the specific heat bear out the magnetic transitions with some delocalized character of the uranium 5f electrons. - Graphical abstract: The phase relations within the U-Al-Ge ternary system were experimentally assessed for two isothermal sections, at 673 K for the whole Gibbs triangle and at 1173 K for the concentration range 25–100 at% U. A complete UAl{sub 3}-UGe{sub 3} solid-solution based on the Cu{sub 3}Au-type forms

  1. MIMS - MEDICAL INFORMATION MANAGEMENT SYSTEM

    Science.gov (United States)

    Frankowski, J. W.

    1994-01-01

    MIMS, Medical Information Management System is an interactive, general purpose information storage and retrieval system. It was first designed to be used in medical data management, and can be used to handle all aspects of data related to patient care. Other areas of application for MIMS include: managing occupational safety data in the public and private sectors; handling judicial information where speed and accuracy are high priorities; systemizing purchasing and procurement systems; and analyzing organizational cost structures. Because of its free format design, MIMS can offer immediate assistance where manipulation of large data bases is required. File structures, data categories, field lengths and formats, including alphabetic and/or numeric, are all user defined. The user can quickly and efficiently extract, display, and analyze the data. Three means of extracting data are provided: certain short items of information, such as social security numbers, can be used to uniquely identify each record for quick access; records can be selected which match conditions defined by the user; and specific categories of data can be selected. Data may be displayed and analyzed in several ways which include: generating tabular information assembled from comparison of all the records on the system; generating statistical information on numeric data such as means, standard deviations and standard errors; and displaying formatted listings of output data. The MIMS program is written in Microsoft FORTRAN-77. It was designed to operate on IBM Personal Computers and compatibles running under PC or MS DOS 2.00 or higher. MIMS was developed in 1987.

  2. Application of JLab 12GeV helium refrigeration system for the FRIB accelerator at MSU

    International Nuclear Information System (INIS)

    Ganni, V.; Knudsen, P.; Arenius, D.; Casagrande, F.

    2014-01-01

    The planned approach to have a turnkey helium refrigeration system for the MSU-FRIB accelerator system, encompassing the design, fabrication, installation and commissioning of the 4.5-K refrigerator cold box(es), cold compression system, warm compression system, gas management, oil removal and utility/ancillary systems, was found to be cost prohibitive. Following JLab’s suggestion, MSU-FRIB accelerator management made a formal request to evaluate the applicability of the recently designed 12GeV JLab cryogenic system for this application. The following paper will outline the findings and the planned approach for the FRIB helium refrigeration system

  3. Army medical imaging system: ARMIS

    International Nuclear Information System (INIS)

    Siedband, M.P.; Kramp, D.C.

    1987-01-01

    Recent advances of stimulable phosphor screens, data cards using optical storage means, and new personal computers with image processing capability have made possible the design of economical filmless medical imaging systems. The addition of communication links means that remote interpretation of images is also possible. The Army Medical Imaging System uses stimulable phosphor screens, digital readout, a small computer, an optical digital data card device, and a DIN/PACS link. Up to 200 images can be stored in the computer hard disk for rapid recall and reading by the radiologist. The computer permits image processing, annotation, insertion of text, and control of the system. Each device contains an image storage RAM and communicates with the computer via the small computer systems interface. Data compression is used to reduce the required storage capacity and transmission times of the 1-mB images. The credit card-size optical data cards replace film and can store 12 or more images. The data cards can be read on an independent viewer. The research is supported by the U.S. Army Biomedical Research and Development Laboratory

  4. Quality system for Medical laboratories

    Directory of Open Access Journals (Sweden)

    Shiva Raj K.C.

    2015-03-01

    Full Text Available According to William Edwards Deming “Good quality does not necessarily mean high quality. Instead it means a predicable degree of uniformity and dependability at low cost with a quality suited to the market.” Whereas according to famous engineer and management consultant Joseph M. Juran quality is “fitness for purpose”. It should meet the customers’ expectations and requirements, should be cost effective.ISO began in 1926 as the International Federation of the National Standardizing Associations (ISA. The name, "ISO" was derived from the Greek word "isos" meaning "equal". (The relation to standards is that if two objects meet the same standard, they should be equal. This name eliminates any confusion that could result from the translation of "International Organization for Standardization" into different languages which would lead to different acronyms.In health sector, quality plays pivotal role, as it is directly related to patient’s care. Earlier time, health service was simple, quite safe but ineffective. Now health care system is an organizational system with more complex processes to deliver care. Medical laboratory service is an integral part in patient’s management system. So, for everyone involved in the treatment of the patient, the accuracy, reliability and safety of those services must be the primary concerns. Accreditation is a significant enabler of quality, thereby delivering confidence to healthcare providers, clinicians, the medical laboratories and the patients themselves.ISO announced meeting in Philadelphia to form a technical committee to develop a new standard for medical laboratory quality. It took 7 years for the creation of a new Quality standard for medical laboratories. It was named as “ISO 15189” and was first published in 2003. The ISO has released three versions of the standard. The first two were released in 2003 and 2007. In 2012, a revised and updated version of the standard, ISO 15189

  5. Some issues on the RF system in the 3 GeV Fermilab pre-booster

    International Nuclear Information System (INIS)

    Ng, K. Y.

    1998-01-01

    Some issues are presented on the rf system in the future Fermilab prebooster, which accelerates 4 bunches each containing 0.25 x 10 14 protons from 1 to 3 GeV kinetic energy. The problem of beam loading is discussed. The proposal of having a non-tunable fixed-frequency rf system is investigated. Robinson's criteria for phase stability are checked and possible Robinson instability growth is computed

  6. Commissioning of Fermilab's Electron Cooling System for 8-GeV Antiprotons

    CERN Document Server

    Nagaitsev, Sergei; Burov, Alexey; Carlson, Kermit; Gai, Wei; Gattuso, Consolato; Hu, Martin; Kazakevich, Grigory; Kramper, Brian J; Kroc, Thomas K; Leibfritz, Jerry; Prost, Lionel; Pruss, Stanley M; Saewert, Greg W; Schmidt, Chuck; Seletsky, Sergey; Shemyakin, Alexander V; Sutherland, Mary; Tupikov, Vitali; Warner, Arden

    2005-01-01

    A 4.3-MeV electron cooling system has been installed at Fermilab in the Recycler antiproton storage ring and is being currently commissioned. The cooling system is designed to assist accumulation of 8.9-GeV/c antiprotons for the Tevatron collider operations. This paper will report on the progress of the electron beam commissioning effort as well as on detailed plans of demonstrating the cooling of antiprotons.

  7. An improved 8 GeV beam transport system for the Fermi National Accelerator Laboratory

    International Nuclear Information System (INIS)

    Syphers, M.J.

    1987-06-01

    A new 8 GeV beam transport system between the Booster and Main Ring synchrotrons at the Fermi National Accelerator Laboratory is presented. The system was developed in an effort to improve the transverse phase space area occupied by the proton beam upon injection into the Main Ring accelerator. Problems with the original system are described and general methods of beamline design are formulated. Errors in the transverse properties of a beamline at the injection point of the second synchrotron and their effects on the region in transverse phase space occupied by a beam of particles are discussed. Results from the commissioning phase of the project are presented as well as measurements of the degree of phase space dilution generated by the transfer of 8 GeV protons from the Booster synchrotron to the Main Ring synchrotron

  8. RF System Modelling for the JLab 12 GeV Upgrade and RIA

    International Nuclear Information System (INIS)

    Alicia Hofler; Jean Delayen; Hovater, J.; Stefan Simrock

    2003-01-01

    Jefferson Lab is using the MATLAB/Simulink library for RF systems developed for TTF as a tool to develop a model of its 12 GeV upgrade and the Rare Isotope Accelerator (RIA) to study the behavior and performance of the RF control system. The library includes elements describing a superconducting cavity with mechanical modes excited by Lorentz Force effects and a klystron including saturation characteristics. It can be applied to gradient and phase or in-phase and quadrature control for cavities operating in either a self-excited loop or generator driven mode. We will provide an overview of the theory behind the library components and present initial modeling results for Jefferson Lab's 12 GeV Upgrade and the RIA systems

  9. Imaging systems for medical diagnostics

    International Nuclear Information System (INIS)

    Krestel, E.

    1990-01-01

    This book provides physicians and clinical physicists with detailed information on today's imaging modalities and assists them in selecting the optimal system for each clinical application. Physicists, engineers and computer specialists engaged in research and development and sales departments will also find this book to be of considerable use. It may also be employed at universities, training centers and in technical seminars. The physiological and physical fundamentals are explained in part 1. The technical solutions contained in part 2 illustrate the numerous possibilities available in X-ray diagnostics, computed tomography, nuclear medical diagnostics, magnetic resonance imaging, sonography and biomagnetic diagnostics. (orig.)

  10. The Ag2Se-HgSe-GeSe2 system and crystal structures of the compounds

    International Nuclear Information System (INIS)

    Parasyuk, O.V.; Gulay, L.D.; Romanyuk, Ya.E.; Olekseyuk, I.D.; Piskach, L.V.

    2003-01-01

    The phase diagram of the quasi-ternary Ag 2 Se-HgSe-GeSe 2 system at 298 K was investigated using X-ray phase analysis and metallography. The formation of five intermediate quaternary phases β (Ag ∼7.12-∼6.32 Hg ∼0.44-∼0.82 GeSe 6 ), γ (Ag ∼6.08-∼4.00 Hg ∼0.96-∼2.00 GeSe 6 ), δ (Ag 3.4 Hg 2.3 GeSe 6 ), ε (Ag ∼2.24-∼2.00 Hg ∼2.88-∼3.00 GeSe 6 ) and ∼Ag 1.4 Hg 1.3 GeSe 6 was established. The crystal structure of the β-phase (for the Ag 6.504 Hg 0.912 GeSe 6 composition) was determined using X-ray single crystal diffraction. It crystallizes in a cubic structure (space group F4-bar 3m) with the lattice parameter a=1.09026(4) nm. The crystal structure of the δ-phase (Ag 3.4 Hg 2.3 GeSe 6 ) was determined using X-ray powder diffraction (space group F4-bar 3m, a=1.07767(8) nm). The crystal structure determination of the γ-phase (space group Pmn2 1 ) was performed for the compositions Ag 5.6 Hg 1.2 GeSe 6 , Ag 4.8 Hg 1.6 GeSe 6 and Ag 4 Hg 2 GeSe 6 using X-ray powder diffraction. The crystal structure of the LT-Hg 2 GeSe 4 compound (space group I4-bar , a=0.56786(2), c=1.12579(5) nm) was confirmed by powder diffraction also.

  11. Conductance relaxation in GeBiTe: Slow thermalization in an open quantum system

    Science.gov (United States)

    Ovadyahu, Z.

    2018-02-01

    This work describes the microstructure and transport properties of GeBixTey films with emphasis on their out-of-equilibrium behavior. Persistent-photoconductivity (PPC), previously studied in the phase-change compound GeSbxTey , is also quite prominent in this system. Much weaker PPC response is observed in the pure GeTe compound and when alloying GeTe with either In or Mn. Films made from these compounds share the same crystallographic structure, the same p -type conductivity, a similar compositional disorder extending over mesoscopic scales, and similar mosaic morphology. The enhanced photoconductive response exhibited by the Sb and Bi alloys may therefore be related to their common chemistry. Persistent photoconductivity is observable in GeBixTey films at the entire range of sheet resistances studied in this work (≈103Ω to ≈55 M Ω ). The excess conductance produced by a brief exposure to infrared illumination decays with time as a stretched exponential (Kohlrausch law). Intrinsic electron-glass effects, on the other hand, are observable in thin films of GeBixTey only for samples that are strongly localized just like it was noted with the seven electron glasses previously studied. These include a memory dip which is the defining attribute of the phenomenon. The memory dip in GeBixTey is the widest amongst the germanium-telluride alloys studied to date consistent with the high carrier concentration N ≥1021cm-3 of this compound. The thermalization process exhibited in either the PPC state or in the electron-glass regime is sluggish but the temporal law of the relaxation from the out-of-equilibrium state is distinctly different. Coexistence of the two phenomena give rise to some nontrivial effects, in particular, the visibility of the memory dip is enhanced in the PPC state. The relation between this effect and the dependence of the memory-effect magnitude on the ratio between the interparticle interaction and quench disorder is discussed.

  12. Commissioning and operational results of the 12 GeV helium compression system at Jlab

    Energy Technology Data Exchange (ETDEWEB)

    Knudsen, Peter N. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Ganni, Venkatarao [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Dixon, Kelly D. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Norton, Robert O. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Creel, Jonathan D. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)

    2015-12-01

    The new compressor system at Jefferson Lab (JLab) for the 12 GeV upgrade was commissioned in the spring of 2013 and incorporates many design changes, discussed in previous publications, to improve the operational range, efficiency, reliability and maintainability as compared to previous compressor skids used for this application. The 12 GeV helium compression system has five compressors configured with four pressure levels supporting three pressure levels in the new cold box. During compressor commissioning the compressors were operated independent of the cold box over a wide range of process conditions to verify proper performance including adequate cooling and oil removal. Isothermal and volumetric efficiencies over these process conditions for several built-involume ratios were obtained. This paper will discuss the operational envelope results and the modifications/improvements incorporated into the skids.

  13. Physical properties of glasses in the Ag2GeS3-AgBr system

    Science.gov (United States)

    Moroz, M. V.; Demchenko, P. Yu.; Prokhorenko, S. V.; Moroz, V. M.

    2013-08-01

    Glasses have been prepared by quenching melts in the Ag2GeS3-AgBr system in a range of 0-53 mol % AgBr. The concentration dependences of density, microhardness, glass transition temperatures, and crystallization of alloys have been established. The conductivity of glasses has been investigated by the dc probe method in a range of 240-420 K. The models of the drift motion of silver and halogen ions have been proposed.

  14. X-ray electron spectra of chalcogenide glasses and polycrystalline alloys of Ge-Te and As-Te systems

    International Nuclear Information System (INIS)

    Panus, V.R.

    1990-01-01

    Comparative investigation into structures of crystals and glasses in Ge-Te and As-Te two-component systems was conducted. Analysis of x-ray electron spectra of Ge-Te and As-Te systems indicates, that processes of dissociation-association resulting in formation of new structure units occur in telluride melts at synthesis temperatures. Structural chemical composition of binary glass-like alloys of Ge-Te and As-Te systems differs essentially from the one that corresponds to fusibility equilibrium curve. Oxygen doping into tellurium-base glasses results mainly in occurence of structures forecasted due to thermochemical calculation

  15. GeVaDSs – decision support system for novel Genetic Vaccine development process

    Directory of Open Access Journals (Sweden)

    Blazewicz Jacek

    2012-05-01

    Full Text Available Abstract Background The lack of a uniform way for qualitative and quantitative evaluation of vaccine candidates under development led us to set up a standardized scheme for vaccine efficacy and safety evaluation. We developed and implemented molecular and immunology methods, and designed support tools for immunization data storage and analyses. Such collection can create a unique opportunity for immunologists to analyse data delivered from their laboratories. Results We designed and implemented GeVaDSs (Genetic Vaccine Decision Support system an interactive system for efficient storage, integration, retrieval and representation of data. Moreover, GeVaDSs allows for relevant association and interpretation of data, and thus for knowledge-based generation of testable hypotheses of vaccine responses. Conclusions GeVaDSs has been tested by several laboratories in Europe, and proved its usefulness in vaccine analysis. Case study of its application is presented in the additional files. The system is available at: http://gevads.cs.put.poznan.pl/preview/(login: viewer, password: password.

  16. Injector system design of the 8 GeV synchrotron radiation facility (SPring-8)

    International Nuclear Information System (INIS)

    Harami, T.; Yokomizo, H.; Ohtsuka, H.

    1990-01-01

    The 8 GeV synchrotron radiation facility, named SPring-8, which will be constructed at Nishi-harima in Hyogo-ken, is designed jointly by JAERI (Japan Atomic Energy Research Institute and RIKEN (Institute of Physical and Chemical Research) under the supervision of Science and Technology Agency (STA) of the Japanese government. The facility provides photon in the X-ray and hard X-ray domains with high flux and high brilliance. The major characteristics of the storage ring are the low emittance and the large number of straight sections. Combining the low emittance beam with long insertion devices, several orders of magnitude improvement in intensity and brightness are expected. The injector system of SPring-8 is composed of a linac and a synchrotron. Not only electrons but positrons can be accelerated by the linac. These particles are injected into the synchrotron and further accelerated to 8 GeV. (N.K.)

  17. Kinetics of formation of the A-15 phase in the Nb--Al--Ge system

    International Nuclear Information System (INIS)

    Kannatey-Asibu, E. Jr.

    1977-05-01

    A study has been made of the time and temperature dependence of the growth of the A-15 phase and its grains in the Nb-Al-Ge system. In addition, changes in the microstructure and composition of the A-15 phase have been studied using an EDAX analysis. The data obtained have been plotted and compared with theory. The results have been used to explain the variations in the superconducting properties of this system as observed in earlier work. Consequently, areas for further study towards optimizing the superconducting parameters of this system have been proposed

  18. Studies on the decay of 160Tb to levels in 160Dy by Ge (Li)-Ge(Li)-coincidence system

    International Nuclear Information System (INIS)

    Hassan, A.M.; Abou-Zeid, M.A.; Mekamer, M.

    1981-01-01

    This work concerned with the study of the energy levels and the properties of gamma-ray transitions in 160 Dy resulting from the B-decay of the parent radioactive isotope 160 Tb (72 d.). These studies have been done by means of, single and gamma-gamma coincidence measurements. Log(ft). Internal Conversion Coefficient (ICC) values and the branching ratios have been calculated. The construction and testes of the Ge(Li)-Ge(Li) gamma-gamma coincidence spectrometer are presented. In addition to the previously reported transitions in three new transitions of energies 203, 420 and 1048 keV have been observed for the first time. The energy level at 1288.60 keV is confirmed, due to the presence of the 246 keV and 1005 keV gamma-ray transitions in the singles and gamma-gamma coincidence spectra. Furthermore the B-intensity feeding this level was calculated for the first time to be 0.08%. The log(ft) values of the energy level at 1288.6 keV was calculated for the first time to be 10.79. The energy level diagram of 160 Dy as summerised in the present work consists of 12 excited states, the levels at 581(6 + ) and 1391 keV reported by some authors were not encluded, since no transitions populated or depopulated these levels could be observed

  19. Study of resonant magnet exciting system for the 3 GeV proton synchrotron

    Energy Technology Data Exchange (ETDEWEB)

    Koseki, Shoichiro; Zhang, Fengqing; Watanabe, Yasuhiro; Tani, Norio [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Adachi, Toshikazu; Someya, Hirohiko [High Energy Accelerator Research Organization, Tsukuba, Ibaraki (Japan)

    2001-07-01

    Exciting system for magnets of the 3 GeV Proton synchrotron is under consideration. A resonant exciting system is studied, and two type of power supply are compared. One is a parallel supply that is used generally. Another is a modified series supply. Either of them uses IGBT sinusoidal converters. Capacity of the power converter of the series supply for bending magnets becomes 28.8 MVAp. This is lager more than twice compared with the parallel supply. In the other hand, the series supply has good control performance and flexibility. More study is necessary to decide finally. (author)

  20. Design for ANL 7 GeV storage ring vacuum system

    International Nuclear Information System (INIS)

    Wehrle, R.B.; Nielsen, R.W.

    1988-01-01

    The 7-GeV Advanced Photon Source (APS) design includes a storage ring having a 1060-m circumference with the capability of accommodating 34 insertion devices (ID) and their associated photon beam lines. An additional 35 photon lines can be provided from bending magnets. The vacuum system for the storage ring is designed to maintain a beam-on operating pressure of 1n Torr or less to achieve a positron beam lifetime of approximately 20 hours. The vacuum system and it's current developmental status are described

  1. Medical Robots: Current Systems and Research Directions

    Directory of Open Access Journals (Sweden)

    Ryan A. Beasley

    2012-01-01

    Full Text Available First used medically in 1985, robots now make an impact in laparoscopy, neurosurgery, orthopedic surgery, emergency response, and various other medical disciplines. This paper provides a review of medical robot history and surveys the capabilities of current medical robot systems, primarily focusing on commercially available systems while covering a few prominent research projects. By examining robotic systems across time and disciplines, trends are discernible that imply future capabilities of medical robots, for example, increased usage of intraoperative images, improved robot arm design, and haptic feedback to guide the surgeon.

  2. Control System of 3 GeV Rapid Cycling Synchrotron at J-PARC

    CERN Document Server

    Takahashi, Hiroki; Kato, Yuko; Kawase, Masato; Sakaki, Hironao; Sako, Hiroyuki; Sugimoto, Makoto; Yoshikawa, Hiroshi

    2005-01-01

    Since the 3GeV RCS produces huge beam power of 1 MW, extreme cares must be taken to design the control system in order to minimize radiation due to beam loss. Another complexity appears in the control system, because each beam bunch of 25 Hz is required to be injected either into the MLF* or into the 50GeV MR.** Therefore, each bunch of 25 Hz must be operated separately, and the data acquisition system must collect synchronized data within each pulse. To achieve these goals, a control system via reflective memory and wave endless recorders has been developed. EPICS is adopted in the control system. Since the number of devices is huge, the management of EPICS records and their configurations require huge amount of time and man power. To reduce this work significantly, a RDB*** for static machine information has been developed. This RDB stores (1) EPICS related information of devices, interfaces, and IOC's**** with a capability to generate EPICS records automatically, and (2) machine geometrical information wit...

  3. Personnel protection and beam containment systems for the 3 GeV Injector

    International Nuclear Information System (INIS)

    Yotam, R.; Cerino, J.; Garoutte, R.; Hettel, R.; Horton, M.; Sebek, J.; Benson, E.; Crook, K.; Fitch, J.; Ipe, N.; Nelson, G.; Smith, H.

    1991-01-01

    The 3 GeV Injector is the electron beam source for the SPEAR Storage Ring, and its personnel safety system was designed to protect personnel from both radiation exposure and electrical hazards. The Personnel Protection System (PPS) was designed and implemented with complete redundancy and is a relay based interlock system completely independent from the machine protection system. A comprehensive monitoring of the system status, and control of the Injector PPS from the SPEAR Control Room via the control computer is a feature. The Beam Containment System (BCS) is based on beam current measurements along the Linac and on Beam Shut Off Ion Chambers (BSOIC) installed outside the Linac, at several locations around the Booster, and around the SPEAR storage ring. An outline of the design criteria is presented with more detailed description of the philosophy of the PPS logic and the BCS

  4. Klystron-modulator system availability of PLS 2 GeV electron linac

    International Nuclear Information System (INIS)

    Cho, M.H.; Park, S.S.; Oh, J.S.; Namkung, W.

    1996-01-01

    PLS Linac has been injecting 2 GeV electron beams to the Pohang Light Source (PLS) storage ring since September 1994. PLS 2 GeV linac employs 11 sets of high power klystron-modulator (K and M) system for the main RF source for the beam acceleration. The klystron has rated output peak power of 80 MW at 4 microsec pulse width and at 60 pps. The matching modulator has 200 MW peak output power. The total accumulated high voltage run time of the oldest unit has reached beyond 23,000 hour and the sum of all the high voltage run time is approximately 230,000 hour as of May 1996. In this paper, we review overall system performance of the high-power K and M system. A special attention is paid on the analysis of all failures and troubles of the K and M system which affected the linac high power RF operations as well as beam injection operations for the period of 1994 to May 1996. (author)

  5. Structural studies of gels and gel-glasses in the SiO2-GeO2 system using vibrational spectroscopy

    Science.gov (United States)

    Mukherjee, Shyama P.; Sharma, Shiv K.

    1986-01-01

    GeO2 gel and gels in the SiO2-GeO2 system synthesized by the hydrolytic polycondensation of metal alkoxides have been studied by infrared and Raman spectroscopic techniques. The molecular structures, hydroxyl contents, and crystallinity of gels and gel-glasses in relation to the thermal history and GeO2 concentration were investigated. The binary compositions having up to 70 mol percent GeO2 were examined.

  6. Exploration Medical Cap Ability System Engineering Overview

    Science.gov (United States)

    McGuire, K.; Mindock, J.

    2018-01-01

    Deep Space Gateway and Transport missions will change the way NASA currently practices medicine. The missions will require more autonomous capability compared to current low Earth orbit operations. For the medical system, lack of consumable resupply, evacuation opportunities, and real-time ground support are key drivers toward greater autonomy. Recognition of the limited mission and vehicle resources available to carry out exploration missions motivates the Exploration Medical Capability (ExMC) Element's approach to enabling the necessary autonomy. The ExMC Systems Engineering team's mission is to "Define, develop, validate, and manage the technical system design needed to implement exploration medical capabilities for Mars and test the design in a progression of proving grounds." The Element's work must integrate with the overall exploration mission and vehicle design efforts to successfully provide exploration medical capabilities. ExMC is using Model-Based System Engineering (MBSE) to accomplish its integrative goals. The MBSE approach to medical system design offers a paradigm shift toward greater integration between vehicle and the medical system, and directly supports the transition of Earth-reliant ISS operations to the Earth-independent operations envisioned for Mars. This talk will discuss how ExMC is using MBSE to define operational needs, decompose requirements and architecture, and identify medical capabilities needed to support human exploration. How MBSE is being used to integrate across disciplines and NASA Centers will also be described. The medical system being discussed in this talk is one system within larger habitat systems. Data generated within the medical system will be inputs to other systems and vice versa. This talk will also describe the next steps in model development that include: modeling the different systems that comprise the larger system and interact with the medical system, understanding how the various systems work together, and

  7. Management of pediatric radiation dose using GE's Revolution digital radiography systems

    International Nuclear Information System (INIS)

    Jabri, K.N.; Uppaluri, R.; Xue Ping

    2004-01-01

    Digital flat-panel X-ray detectors offer excellent image quality and dose efficiency in addition to clinical productivity, connectivity, and adaptability to advanced clinical applications. GE's Revolution systems provide two modes of exposure control for setting the dose operating point, fixed time and automatic exposure control, the latter of which maintains high image signal-to-noise ratio for the given technique settings. In addition to enhancing detail contrast and compressing the dynamic range, postprocessing automatically determines the best window level and width for display, taking into account the dose at which the image was acquired. Several studies have examined the reduction in patient dose achievable with Revolution systems as compared to competing technologies, and results indicate significant dose savings with equivalent or superior image quality. For pediatric exams, pediatric default techniques provide for a lower patient dose as compared to adult techniques. Therefore, GE's Revolution systems can achieve a high image quality-to-dose ratio for pediatric imaging using the combined advantages of dose-efficient detection, advanced postprocessing, and independently adjustable pediatric techniques. (orig.)

  8. MINDS - Medical Information Network Decision Support System

    National Research Council Canada - National Science Library

    Armenian, H. K

    2008-01-01

    .... The increase in and complexity of medical data at various levels of resolution has increased the need for system level advancements in clinical decision support systems that provide computer-aided...

  9. Systems Engineering for Space Exploration Medical Capabilities

    Science.gov (United States)

    Mindock, Jennifer; Reilly, Jeffrey; Rubin, David; Urbina, Michelle; Hailey, Melinda; Hanson, Andrea; Burba, Tyler; McGuire, Kerry; Cerro, Jeffrey; Middour, Chris; hide

    2017-01-01

    Human exploration missions that reach destinations beyond low Earth orbit, such as Mars, will present significant new challenges to crew health management. For the medical system, lack of consumable resupply, evacuation opportunities, and real-time ground support are key drivers toward greater autonomy. Recognition of the limited mission and vehicle resources available to carry out exploration missions motivates the Exploration Medical Capability (ExMC) Element's approach to enabling the necessary autonomy. The Element's work must integrate with the overall exploration mission and vehicle design efforts to successfully provide exploration medical capabilities. ExMC is applying systems engineering principles and practices to accomplish its goals. This paper discusses the structured and integrative approach that is guiding the medical system technical development. Assumptions for the required levels of care on exploration missions, medical system goals, and a Concept of Operations are early products that capture and clarify stakeholder expectations. Model-Based Systems Engineering techniques are then applied to define medical system behavior and architecture. Interfaces to other flight and ground systems, and within the medical system are identified and defined. Initial requirements and traceability are established, which sets the stage for identification of future technology development needs. An early approach for verification and validation, taking advantage of terrestrial and near-Earth exploration system analogs, is also defined to further guide system planning and development.

  10. [A medical consumable material management information system].

    Science.gov (United States)

    Tang, Guoping; Hu, Liang

    2014-05-01

    Medical consumables material is essential supplies to carry out medical work, which has a wide range of varieties and a large amount of usage. How to manage it feasibly and efficiently that has been a topic of concern to everyone. This article discussed about how to design a medical consumable material management information system that has a set of standardized processes, bring together medical supplies administrator, suppliers and clinical departments. Advanced management mode, enterprise resource planning (ERP) applied to the whole system design process.

  11. Conceptual Drivers for an Exploration Medical System

    Science.gov (United States)

    Antonsen, Erik; Hanson, Andrea; Shah, Ronak; Reed, Rebekah; Canga, Michael

    2016-01-01

    Interplanetary spaceflight, such as NASA's proposed three-year mission to Mars, provides unique and novel challenges when compared with human spaceflight to date. Extended distance and multi-year missions introduce new elements of operational complexity and additional risk. These elements include: inability to resupply medications and consumables, inability to evacuate injured or ill crew, uncharted psychosocial conditions, and communication delays that create a requirement for some level of autonomous medical capability. Because of these unique challenges, the approaches used in prior programs have limited application to a Mars mission. On a Mars mission, resource limitations will significantly constrain available medical capabilities, and require a paradigm shift in the approach to medical system design and risk mitigation for crew health. To respond to this need for a new paradigm, the Exploration Medical Capability (ExMC) Element is assessing each Mars mission phase-transit, surface stay, rendezvous, extravehicular activity, and return-to identify and prioritize medical needs for the journey beyond low Earth orbit (LEO). ExMC is addressing both planned medical operations, and unplanned contingency medical operations that meld clinical needs and research needs into a single system. This assessment is being used to derive a gap analysis and studies to support meaningful medical capabilities trades. These trades, in turn, allow the exploration medical system design to proceed from both a mission centric and ethics-based approach, and to manage the risks associated with the medical limitations inherent in an exploration class mission. This paper outlines the conceptual drivers used to derive medical system and vehicle needs from an integrated vision of how medical care will be provided within this paradigm. Keywords: (Max 6 keywords: exploration, medicine, spaceflight, Mars, research, NASA)

  12. Exploration Medical System Trade Study Tools Overview

    Science.gov (United States)

    Mindock, J.; Myers, J.; Latorella, K.; Cerro, J.; Hanson, A.; Hailey, M.; Middour, C.

    2018-01-01

    ExMC is creating an ecosystem of tools to enable well-informed medical system trade studies. The suite of tools address important system implementation aspects of the space medical capabilities trade space and are being built using knowledge from the medical community regarding the unique aspects of space flight. Two integrating models, a systems engineering model and a medical risk analysis model, tie the tools together to produce an integrated assessment of the medical system and its ability to achieve medical system target requirements. This presentation will provide an overview of the various tools that are a part of the tool ecosystem. Initially, the presentation's focus will address the tools that supply the foundational information to the ecosystem. Specifically, the talk will describe how information that describes how medicine will be practiced is captured and categorized for efficient utilization in the tool suite. For example, the talk will include capturing what conditions will be planned for in-mission treatment, planned medical activities (e.g., periodic physical exam), required medical capabilities (e.g., provide imaging), and options to implement the capabilities (e.g., an ultrasound device). Database storage and configuration management will also be discussed. The presentation will include an overview of how these information tools will be tied to parameters in a Systems Modeling Language (SysML) model, allowing traceability to system behavioral, structural, and requirements content. The discussion will also describe an HRP-led enhanced risk assessment model developed to provide quantitative insight into each capability's contribution to mission success. Key outputs from these various tools, to be shared with the space medical and exploration mission development communities, will be assessments of medical system implementation option satisfaction of requirements and per-capability contributions toward achieving requirements.

  13. High-field study of the spin-Peierls system CuGeO{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Regnault, L P [CEA Centre d` Etudes de Grenoble, 38 (France)

    1997-04-01

    The one-dimensional spin-1/2 Heisenberg antiferromagnetic system coupled to a three-dimensional phonon field undergoes a structural distortion below a finite temperature T{sub sp} (spin-Peierls transition) which induces the formation of a non-magnetic singlet ground-state and the opening of a gap in the excitation spectrum at the antiferromagnetic point. The recent discovery of the germanate CuGeO{sub 3} as a spin-Peierls system has considerably renewed the interest is this fascinating phenomenon. Inelastic neutron scattering and neutron diffraction have brought very quantitative pieces of information which can be directly compared to the predictions of the standard model. (author). 6 refs.

  14. Vacuum system for the Argonne 6 GeV synchrotron light source

    International Nuclear Information System (INIS)

    Wehrle, R.; Moenich, J.

    1985-01-01

    The ANL vacuum system for the 6 GeV light source storage ring features non-evaporable strip getter pumps for uniform pumping around the ring within a gas desorption antechamber, and it also features lumped getter pumping directly under and above crotch radiation absorbers that are positioned after each bending magnet. Based on experiments at ANL in 1980 and by others, the technical and economical advantages have been established for the use of the distributed NeG pumps of non-magnetic strips coated with a non-evaporable Zr Al getter matrix. The NeG strip pump lifetime approaches ten years. The antechamber improves the isolation of the gas desorption process from the main beam chamber and beam. The combination of these vacuum techniques; the NeG strip getter pumps, the gas desorption antechambers, and the lumped ion and lumped getter pumping provide a unique and reliable system for maintaining long beam lifetime

  15. Structural and thermodynamic similarities of phases in the Li-Tt (Tt = Si, Ge) systems: redetermination of the lithium-rich side of the Li-Ge phase diagram and crystal structures of Li17Si4.0-xGex for x = 2.3, 3.1, 3.5, and 4 as well as Li4.1Ge.

    Science.gov (United States)

    Zeilinger, Michael; Fässler, Thomas F

    2014-10-28

    A reinvestigation of the lithium-rich section of the Li-Ge phase diagram reveals the existence of two new phases, Li17Ge4 and Li4.10Ge (Li16.38Ge4). Their structures are determined by X-ray diffraction experiments of large single crystals obtained from equilibrated melts with compositions Li95Ge5 and Li85Ge15. Excess melt is subsequently removed through isothermal centrifugation at 400 °C and 530 °C, respectively. Li17Ge4 crystallizes in the space group F4[combining macron]3m (a = 18.8521(3) Å, V = 6700.1(2) Å(3), Z = 20, T = 298 K) and Li4.10Ge (Li16.38Ge4) in Cmcm (a = 4.5511(2) Å, b = 22.0862(7) Å, c = 13.2751(4) Å, V = 1334.37(8) Å(3), Z = 16, T = 123 K). Both phases are isotypic with their Si counterparts and are further representative of the Li17Pb4 and Li4.11Si structure types. Additionally, the solid solutions Li17Si4-xGex follows Vegard's law. A comparison of the GeLin coordination polyhedra shows that isolated Ge atoms are 13- and 14-coordinated in Li17Ge4, whereas in Li16.38Ge4 the Ge atoms possess coordination numbers 12 and 13. Regarding the thermodynamic stability, Li16.38Ge4 is assigned a high-temperature phase existing between ∼400 °C and 627 °C, whereas Li17Ge4 decomposes peritectically at 520-522 °C. Additionally, the decomposition of Li16.38Ge4 below ∼400 °C was found to be very sluggish. These findings are manifested by differential scanning calorimetry, long-term annealing experiments and the results from melt equilibration experiments. Interestingly, the thermodynamic properties of the lithium-rich tetrelides Li17Tt4 and Li4.1Tt (Li16.4Tt4) are very similar (Tt = Si, Ge). Besides Li15Tt4, Li14Tt6, Li12Tt7, and LiTt, the title compounds are further examples of isotypic tetrelides in the systems Li-Tt.

  16. Exploration Medical System Technical Architecture Overview

    Science.gov (United States)

    Cerro, J.; Rubin, D.; Mindock, J.; Middour, C.; McGuire, K.; Hanson, A.; Reilly, J.; Burba, T.; Urbina, M.

    2018-01-01

    The Exploration Medical Capability (ExMC) Element Systems Engineering (SE) goals include defining the technical system needed to support medical capabilities for a Mars exploration mission. A draft medical system architecture was developed based on stakeholder needs, system goals, and system behaviors, as captured in an ExMC concept of operations document and a system model. This talk will discuss a high-level view of the medical system, as part of a larger crew health and performance system, both of which will support crew during Deep Space Transport missions. Other mission components, such as the flight system, ground system, caregiver, and patient, will be discussed as aspects of the context because the medical system will have important interactions with each. Additionally, important interactions with other aspects of the crew health and performance system are anticipated, such as health & wellness, mission task performance support, and environmental protection. This talk will highlight areas in which we are working with other disciplines to understand these interactions.

  17. Robust Medical Isotope Production System

    Energy Technology Data Exchange (ETDEWEB)

    Klein, Steven Karl [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Kimpland, Robert Herbert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-06-15

    The success of this theoretical undertaking provided confidence that the behavior of new and evolving designs of fissile solution systems may be accurately estimated. Scaled up versions of SUPO, subcritical acceleratordriven systems, and other evolutionary designs have been examined.

  18. Rapid measurement of 131I in the thyroid gland using a portable Ge system

    International Nuclear Information System (INIS)

    Kawamura, H.; Kimura, S.

    2000-01-01

    Rapid yet accurate measurement of the 131 I activity in the thyroid gland as well as in the air, water and vegetation may have an important role in obtaining quantitative information on internal doses for the people living in the vicinity of nuclear facilities shortly after an accidental release of radionuclides. Whole body counting technique is still the standard method for measuring radionuclides in the body while necessity for in situ measurement techniques has considerably increased especially after the Three Mile Island and Chernobyl accidents. For measurement of 131 I in the thyroid gland in emergency situations, NaI (Tl) detectors, as in a scintillation survey meter as in the simplest case, are most often used while measurement of urinary excretions for members of the public may also effective. The scintillation survey meter method, being easily implemented, may not have enough selectivity for radioiodine and even be liable to an elevated background radiation spectrum. This would possibly lead to higher detection limits and lower accuracy. A use of a laboratory Ge (Li) detector system in the thyroidal radioiodine measurement was suggested to overcome the problem. A real measurement with a similar instrument was reported for the residents in U.K. after the Chernobyl accident. A use of a scintillation spectro-survey meter with a NaI (Tl) probe with lead collimation to thyroidal radioiodine measurement was also reported to give satisfactorily accurate evaluation of the thyroidal 131 I burden. In this paper, a movable Ge system was developed for the above purpose and preliminarily evaluated particularly for counting efficiency. It is consisted of a portable high-purity Ge detector and a battery-operated MCA. It employs a laboratory made thin Pb shield with a collimation window and an elevator for the detector platform. The elevator was designed to adjust the height of the thyroid radioiodine probe in relation to the height and position of the neck of a subject

  19. Lattice parameters values and phase diagram for the Cu2Zn1-zFezGeSe4 alloy system

    International Nuclear Information System (INIS)

    Caldera, D.; Quintero, M.; Morocoima, M.; Quintero, E.; Grima, P.; Marchan, N.; Moreno, E.; Bocaranda, P.; Delgado, G.E.; Mora, A.E.; Briceno, J.M.; Fernandez, J.L.

    2008-01-01

    X-ray powder diffraction and differential thermal analysis (DTA) measurements were made on polycrystalline samples of the Cu 2 Zn 1-z Fe z GeSe 4 alloy system. The diffraction patterns were used to show the equilibrium conditions and to estimate crystalline parameter values. It was found that, at room temperature, a single phase solid solution with the tetragonal stannite α structure (I4-bar2m) occurs across the whole composition range. The DTA thermograms were used to construct the phase diagram of the Cu 2 Zn 1-z Fe z GeSe 4 alloy system. It was confirmed that the Cu 2 ZnGeSe 4 compound melts incongruently. It was observed that undercooling effects occur for samples with z > 0.9

  20. Implementation of an Electronic Medical Records System

    Science.gov (United States)

    2008-05-07

    Hartman, MAJ Roddex Barlow , CPT Christopher Besser and Capt Michael Emerson...thank you I am truly honored to call each of you my friends. Electronic... abnormal findings are addressed. 18 Electronic Medical Record Implementation Barriers of the Electronic Medical Records System There are several...examination findings • Psychological and social assessment findings N. The system provides a flexible mechanism for retrieval of encounter

  1. Medical cyber-physical systems: A survey.

    Science.gov (United States)

    Dey, Nilanjan; Ashour, Amira S; Shi, Fuqian; Fong, Simon James; Tavares, João Manuel R S

    2018-03-10

    Medical cyber-physical systems (MCPS) are healthcare critical integration of a network of medical devices. These systems are progressively used in hospitals to achieve a continuous high-quality healthcare. The MCPS design faces numerous challenges, including inoperability, security/privacy, and high assurance in the system software. In the current work, the infrastructure of the cyber-physical systems (CPS) are reviewed and discussed. This article enriched the researches of the networked Medical Device (MD) systems to increase the efficiency and safety of the healthcare. It also can assist the specialists of medical device to overcome crucial issues related to medical devices, and the challenges facing the design of the medical device's network. The concept of the social networking and its security along with the concept of the wireless sensor networks (WSNs) are addressed. Afterward, the CPS systems and platforms have been established, where more focus was directed toward CPS-based healthcare. The big data framework of CPSs is also included.

  2. Building a medical system for nuclear facilities

    International Nuclear Information System (INIS)

    Maeda, Mitsuya

    2016-01-01

    To build a medical system for nuclear facilities, I explained what kinds of actions were performed with the TEPCO Fukushima Daiichi Nuclear Power Plant Accident and what kinds of actions are going to be performed in the future. We examined the health and medical care of the emergency workers in nuclear facilities including TEPCO Fukushima Daiichi Nuclear Power Plant from 2014 to 2015 in the Ministry of Health, Labour and Welfare (MHLW). We carried out a detailed hearing from stakeholders of electric companies and medical institutions about the medical system in nuclear facilities carrying out urgent activities. It has been said that the electric company is responsible to maintain the medical system for affected workers in nuclear facilities. However, TEPCO could not find the medical staff, such as doctors, by their own effort at the TEPCO Fukushima Daiichi Nuclear Power Plant Accident. The network of doctors familiar with emergency medical care support dispatched the medical staff after July of 2011. The stakeholders indicated that the following six tasks must be resolved: (1) the fact that no electric company performs the action of bringing up medical staff who can be dispatched into nuclear facilities in emergencies in 2015; (2) bringing up personnel in charge of radiation management and logistics other than the medical staff, such as doctors; (3) cooperation with the community medicine system given the light and shade by nuclear facilities; (4) performing training for the many concurrent wounded based on the scenario of a severe accident; (5) indicating both the condition of the contract and the guarantee of status that is appropriate for dispatched medical staffs; and (6) clarifying the organization of the network of stakeholders. The stakeholders showed the future directionality as follows: (1) To recruit the medical staff expected to be dispatched into nuclear facilities, (2) to carry out the discussion and conveyance training to strengthen cooperation with

  3. Exploration Medical System Demonstration (EMSD) Project

    Science.gov (United States)

    Chin, Duane

    2012-01-01

    The Exploration Medical System Demonstration (EMSD) is a project under the Exploration Medical Capability (ExMC) element managed by the Human Research Program (HRP). The vision for the EMSD is to utilize ISS as a test bed to show that several medical technologies needed for an exploration mission and medical informatics tools for managing evidence and decision making can be integrated into a single system and used by the on-orbit crew in an efficient and meaningful manner. Objectives: a) Reduce and even possibly eliminate the time required for on-orbit crew and ground personnel (which include Surgeon, Biomedical Engineer (BME) Flight Controller, and Medical Operations Data Specialist) to access and move medical data from one application to another. b) Demonstrate that the on-orbit crew has the ability to access medical data/information using an intuitive and crew-friendly software solution to assist/aid in the treatment of a medical condition. c) Develop a common data management framework and architecture that can be ubiquitously used to automate repetitive data collection, management, and communications tasks for all crew health and life sciences activities.

  4. The medical physics specialization system in Poland.

    Science.gov (United States)

    Bulski, Wojciech; Kukołowicz, Paweł; Skrzyński, Witold

    2016-07-01

    This paper presents the situation of the profession of medical physicists in Poland. The official recognition of the profession of medical physicist in Polish legislation was in 2002. In recent years, more and more Universities which have Physics Faculties introduce a medical physics specialty. At present, there are about 15 Universities which offer such programmes. These Universities are able to graduate about 150 medical physicists per year. In 2002, the Ministry of Health introduced a programme of postgraduate specialization in medical physics along the same rules employed in the specialization of physicians in various branches of medicine. Five institutions, mostly large oncology centres, were selected as teaching institutions, based on their experience, the quality of the medical physics professionals, staffing levels, equipment availability, lecture halls, etc. The first cycle of the specialization programme started in 2006, and the first candidates completed their training at the end of 2008, and passed their official state exams in May 2009. As of January 2016, there are 196 specialized medical physicists in Poland. Another about 120 medical physicists are undergoing specialization. The system of training of medical physics professionals in Poland is well established. The principles of postgraduate training and specialization are well defined and the curriculum of the training is very demanding. The programme of specialization was revised in 2011 and is in accordance with EC and EFOMP recommendations. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  5. Structural characterization and compositional dependence of the optical properties of Ge-Ga-La-S chalcohalide glass system

    Science.gov (United States)

    Li, Lini; Jiao, Qing; Lin, Changgui; Dai, Shixun; Nie, Qiuhua

    2018-04-01

    In this paper, chalcogenide glasses of 80GeS2sbnd (20sbnd x)Ga2S3sbnd xLa2S3 (x = 0, 1, 3, 5 mol%) were synthesized through the traditional melt-quenching technique. The effects of La2S3 addition on the thermal, optical, and structural properties of Gesbnd Gasbnd S glasses were investigated. Results showed that the synthesized glasses possessed considerably high glass transition temperature, improved glass forming ability, high refractive index, and excellent infrared transmittance. A redshift at the visible absorbing cut-off edge lower than 500 nm was observed with increasing of La2S3 content. Direct and indirect optical band gap values were calculated. SEM result suggested that this glass system owned better glass forming ability and uniformity. Raman spectral analysis indicated that the introduction of La2S3 induced the dissociation of Gesbnd Ge metal bonds and transformed the [S3Gesbnd GeS3] structure to GeS4 tetrahedrons. Consequently, the connectivity between tetrahedrons of the vitreous network was enhanced. This work suggests that La2S3 modified Ge-Gasbnd Lasbnd S glass is a promising material for infrared optical research.

  6. Family Systems Training for Medical Students.

    Science.gov (United States)

    Thabrew, Hiran

    2018-05-01

    To evaluate whether a workshop on family systems delivered to medical students could improve participants' understanding of families from a systemic point of view and help them recognise and address systemic issues that may be affecting their patients. Fifth year (senior) medical students ( n = 36) from the University of Auckland participated in a 90-min workshop about family systems. Pre- and post-workshop, self-reported measures of knowledge and confidence were completed and qualitative feedback was also obtained from participants. The workshop was well received and its interactive and role-play based nature were particularly appreciated. Participants reported gains in all explored areas of knowledge and understanding, suggesting that the workshop met its desired aims. This workshop is an educationally effective and expedient way to equip medical students with some knowledge and understanding about family systems. It may benefit their future work with individual patients and families.

  7. Superconductivity and anomalous normal state in the CePd2Si2/CeNi2Ge2 system

    International Nuclear Information System (INIS)

    Grosche, F.M.; Lister, S.J.S.; Carter, F.V.; Saxena, S.S.; Haselwimmer, R.K.W.; Mathur, N.D.; Julian, S.R.; Lonzarich, G.G.

    1997-01-01

    The unconventional nonmagnetic metal CeNi 2 Ge 2 is characterised at ambient pressure by temperature dependences of the specific heat and of the resistivity which deviate strongly from standard Fermi-liquid predictions and are reminiscent of the behaviour observed in its sibling system CePd 2 Si 2 above the critical pressure at which magnetic order is suppressed. We have explored the CePd 2 Si 2 /CeNi 2 Ge 2 phase diagram in a series of resistivity measurements under high hydrostatic pressure, p. At p>15 kbar, a new superconducting transition appears below 220 mK in CeNi 2 Ge 2 and shifts to higher temperatures with increasing pressure, reaching ∝400 mK at p∝26 kbar. (orig.)

  8. Phase relations in the quasi-binary Cu{sub 2}GeS{sub 3}-ZnS and quasi-ternary Cu{sub 2}S-Zn(Cd)S-GeS{sub 2} systems and crystal structure of Cu{sub 2}ZnGeS{sub 4}

    Energy Technology Data Exchange (ETDEWEB)

    Parasyuk, O.V. [Department of General and Inorganic Chemistry, Volyn State University, Voli Ave 13, 43009 Lutsk (Ukraine)]. E-mail: oleg@lab.univer.lutsk.ua; Piskach, L.V. [Department of General and Inorganic Chemistry, Volyn State University, Voli Ave 13, 43009 Lutsk (Ukraine); Romanyuk, Y.E. [Advanced Photonics Laboratory, Institute of Imaging and Applied Optics, Ecole Polytechnique Federale de Lausanne, CH-1015 Lausanne (Switzerland); Olekseyuk, I.D. [Department of General and Inorganic Chemistry, Volyn State University, Voli Ave 13, 43009 Lutsk (Ukraine); Zaremba, V.I. [Department of Inorganic Chemistry, Ivan Franko National University of Lviv, 6 Kyryla and Mefodiya Str., 79005 L' viv (Ukraine); Pekhnyo, V.I. [V.I. Vernadskii Institute of General and Inorganic Chemistry, Ukrainian National Academy of Sciences, Palladina Ave 32-34, 03680 Kiev (Ukraine)

    2005-07-19

    The isothermal section of the Cu{sub 2}S-Zn(Cd)S-GeS{sub 2} systems at 670K was constructed using X-ray diffraction analysis. At this temperature, two quaternary intermediate phases, Cu{sub 2}CdGeS{sub 4} and {approx}Cu{sub 8}CdGeS{sub 7}, exist in the Cu{sub 2}S-CdS-GeS{sub 2} system, and only one phase, Cu{sub 2}ZnGeS{sub 4}, exists in the Cu{sub 2}S-ZnS-GeS{sub 2} system. The phase diagram of the Cu{sub 2}GeS{sub 3}-ZnS system was constructed using differential-thermal analysis and X-ray diffraction, and the existence of Cu{sub 2}ZnGeS{sub 4} has been confirmed. It forms incongruently at 1359K. Powder X-ray diffraction was used to refine the crystal structure of Cu{sub 2}ZnGeS{sub 4}, which crystallizes in the tetragonal stannite-type structure at 670K (space group I4-bar 2m, a=0.534127(9)nm, c=1.05090(2)nm, R{sub I}=0.0477). The possibility of the formation of quaternary compounds in the quasi-ternary systems A{sup I}{sub 2}X-B{sup II}X-C{sup IV}X{sub 2}, where A{sup I}-Cu, Ag; B{sup II}-Zn, Cd, Hg; C{sup IV}-Si, Ge, Sn and X-S, Se, Te is discussed.

  9. Super-rapid medical film processing system

    International Nuclear Information System (INIS)

    Honda, C.; Iwata, M.; Nozaki, H.

    1988-01-01

    A new super-rapid medical film processing system cuts processing time from 90 to 45 seconds, a critical advantage in traumatic injury, surgical operation, and other time-vital applications. The system consists of new films new processing chemicals (developer and fixer), and a new high-speed medical film processor. The system's creation is made possible by three new technologies. In film, multilayered monodispersed grains reduce processing time. In processing chemicals, an innovative design maximizes processing speed. And in the processor itself, a new drying apparatus increases drying efficiency. Together, these technologies achieve 45-second processing without degradation of image quality

  10. Gamma-ray pulse height spectrum analysis on systems with multiple Ge detectors using spectrum summing

    Energy Technology Data Exchange (ETDEWEB)

    Killian, E.W. [Idaho National Engineering Lab., Idaho Falls, ID (United States)

    1997-11-01

    A technique has been developed at the Idaho National Engineering Laboratory to sum high resolution gamma-ray pulse spectra from systems with multiple Ge detectors. Lockheed Martin Idaho Technologies Company operates a multi-detector spectrometer configuration at the Stored Waste Examination Pilot Plant facility which is used to characterize the radionuclide contents in waste drums destined for shipment to Waste Isolation Pilot Plant. This summing technique was developed to increase the sensitivity of the system, reduce the count times required to properly quantify the radio-nuclides and provide a more consistent methodology for combining data collected from multiple detectors. In spectrometer systems with multiple detectors looking at non homogeneous waste forms it is often difficult to combine individual spectrum analysis results from each detector to obtain a meaningful result for the total waste container. This is particularly true when the counting statistics in each individual spectrum are poor. The spectrum summing technique adds the spectra collected by each detector into a single spectrum which has better counting statistics than each individual spectrum. A normal spectral analysis program can then be used to analyze the sum spectrum to obtain radio-nuclide values which have smaller errors and do not have to be further manipulated to obtain results for the total waste container. 2 refs., 2 figs.

  11. Gas spectroscopy system with 245 GHz transmitter and receiver in SiGe BiCMOS

    Science.gov (United States)

    Schmalz, Klaus; Rothbart, Nick; Borngräber, Johannes; Yilmaz, Selahattin Berk; Kissinger, Dietmar; Hübers, Heinz-Wilhelm

    2017-02-01

    The implementation of an integrated mm-wave transmitter (TX) and receiver (RX) in SiGe BiCMOS or CMOS technology offers a path towards a compact and low-cost system for gas spectroscopy. Previously, we have demonstrated TXs and RXs for spectroscopy at 238 -252 GHz and 495 - 497 GHz using external phase-locked loops (PLLs) with signal generators for the reference frequency ramps. Here, we present a more compact system by using two external fractional-N PLLs allowing frequency ramps for the TX and RX, and for TX with superimposed frequency shift keying (FSK) or reference frequency modulation realized by a direct digital synthesizer (DDS) or an arbitrary waveform generator. The 1.9 m folded gas absorption cell, the vacuum pumps, as well as the TX and RX are placed on a portable breadboard with dimensions of 75 cm x 45 cm. The system performance is evaluated by high-resolution absorption spectra of gaseous methanol at 13 Pa for 241 - 242 GHz. The 2f (second harmonic) content of the absorption spectrum of the methanol was obtained by detecting the IF power of RX using a diode power sensor connected to a lock-in amplifier. The reference frequency modulation reveals a higher SNR (signal-noise-ratio) of 98 within 32 s acquisition compared to 66 for FSK. The setup allows for jumping to preselected frequency regions according to the spectral signature thus reducing the acquisition time by up to one order of magnitude.

  12. Magnetic and transport behaviour in Pr3X(X=In,Sn,Ga,Ge,Ni,Co,Ru,Ir) systems

    International Nuclear Information System (INIS)

    Garde, C.S.; Ray, J.

    1998-01-01

    Magnetic and transport studies on Pr 3 X (X=In, Sn, Ga, Ge, Ni, Co, Ru, Ir) systems gave evidence for complex magnetic behaviour. All the systems, except X=Sn, exhibit ferromagnetic ordering. The X=Sn system exhibits antiferromagnetic ordering. For X=Ga and Sn, metamagnetic behaviour has been observed. Crystal field effects are found to play an important role in influencing magnetic behaviour. The strength of the crystal field term has also been estimated. (orig.)

  13. Recent progress in the control system of the KEK 2.5 GeV e-/e+ linac

    International Nuclear Information System (INIS)

    Furukawa, Kazuro; Kamikubota, Norihiko; Nakahara, Kazuo; Abe, Isamu

    1990-01-01

    The KEK 2.5 GeV linac is controlled by a distributed processor network having minicomputers and microcomputers interconnected with fiber-optic networks. This system has operated for seven years; however, the system capability has become inadequate for the increasing demands. Thus a new network system, using the TCP/IP protocol suite over Ethernet, has been introduced. New control software to enable more reliable operation of the linac is now under development. (orig.)

  14. Boron mediation on the growth of Ge quantum dots on Si (1 0 0) by ultra high vacuum chemical vapor deposition system

    International Nuclear Information System (INIS)

    Chen, P.S.; Pei, Z.; Peng, Y.H.; Lee, S.W.; Tsai, M.-J.

    2004-01-01

    Self-assembled Ge quantum dots (QDs) with boron mediation are grown on Si (1 0 0) by an industrial hot wall ultra-high-vacuum chemical vapor deposition (UHV/CVD) system with different growth temperatures and dopant gas flow rates. Diborane (B 2 H 6 ) gas is applied as a surfactant on the Si (1 0 0) prior to the growth of Ge QDs. Small dome and pyramid shaped Ge QDs are observed after boron treatment as compared to the hut shaped Ge cluster without boron pre-treatment at 525 and 550 deg. C. The Ge QDs have a typical base width and height of about 30 and 6 nm, respectively, and the density is about 2.5x10 10 cm -2 for the growth temperature of 525 deg. C. Through weakening the Si-H bond during the epitaxy growth and changing the stress field on the surface of the Si (1 0 0) buffer, boron mediation can modify the growth mode of Ge QDs. When the growth temperature is low (525-550 deg. C), the former factor is dominate, as the growth temperature is raised (600 deg. C), the latter parameter may play an important role on the formation of Ge QDs. Optical transition from Ge QDs is demonstrated from photoluminescence (PL) spectra. Furthermore, multifold Ge/Si layers are also carried out to enhance the PL intensity with first Ge layer treated by B 2 H 6 and avoid the generation of threading dislocations

  15. Processing and characterization of new oxy-sulfo-telluride glasses in the Ge-Sb-Te-S-O system

    International Nuclear Information System (INIS)

    Smith, C.; Jackson, J.; Petit, L.; Rivero-Baleine, C.; Richardson, K.

    2010-01-01

    New oxy-sulfo-telluride glasses have been prepared in the Ge-Sb-Te-S-O system employing a two-step melting process which involves the processing of a chalcogenide glass (ChG) and subsequent melting with TeO 2 or Sb 2 O 3 . The progressive incorporation of O at the expense of S was found to increase the density and the glass transition temperature and to decrease the molar volume of the investigated oxy-sulfo-telluride glasses. We also observed a shift of the vis-NIR cut-off wavelength to longer wavelength probably due to changes in Sb coordination within the glass matrix and overall matrix polarizability. Using Raman spectroscopy, correlations have been shown between the formation of Ge- and Sb-based oxysulfide structural units and the S/O ratio. Lastly, two glasses with similar composition (Ge 20 Sb 6 S 64 Te 3 O 7 ) processed by melting the Ge 23 Sb 7 S 70 glass with TeO 2 or the Ge 23 Sb 2 S 72 Te 4 glass with Sb 2 O 3 were found to have slightly different physical, thermal, optical and structural properties. These changes are thought to result mainly from the higher moisture content and sensitivity of the TeO 2 starting materials as compared to that of the Sb 2 O 3 . - Graphical abstract: In this paper, we discuss our most recent findings on the processing and characterization of new ChG glasses prepared with small levels of Te, melted either with TeO 2 or Sb 2 O 3 powders. We explain how these new oxy-sulfo-telluride glasses are prepared and we correlate the physical, thermal and optical properties of the investigated glasses to the structure changes induced by the addition of oxygen in the Ge-Sb-S-Te glass network.

  16. Wearable medical systems for p-Health.

    Science.gov (United States)

    Teng, Xiao-Fei; Zhang, Yuan-Ting; Poon, Carmen C Y; Bonato, Paolo

    2008-01-01

    Driven by the growing aging population, prevalence of chronic diseases, and continuously rising healthcare costs, the healthcare system is undergoing a fundamental transformation, from the conventional hospital-centered system to an individual-centered system. Current and emerging developments in wearable medical systems will have a radical impact on this paradigm shift. Advances in wearable medical systems will enable the accessibility and affordability of healthcare, so that physiological conditions can be monitored not only at sporadic snapshots but also continuously for extended periods of time, making early disease detection and timely response to health threats possible. This paper reviews recent developments in the area of wearable medical systems for p-Health. Enabling technologies for continuous and noninvasive measurements of vital signs and biochemical variables, advances in intelligent biomedical clothing and body area networks, approaches for motion artifact reduction, strategies for wearable energy harvesting, and the establishment of standard protocols for the evaluation of wearable medical devices are presented in this paper with examples of clinical applications of these technologies.

  17. Cryocooler and Thermal Systems for Improved GeD Gamma-ray Imaging and Spectroscopy

    Data.gov (United States)

    National Aeronautics and Space Administration — Place Germanium detectors (GeDs) in a few-MeV γ-ray Compton instrument on a satellite will enable unprecedented insight into nuclear astrophysics, key multimessenger...

  18. Spectroscopic Imaging Using Ge and CdTe Based Detector Systems for Hard X-ray Applications

    Science.gov (United States)

    Astromskas, Vytautas

    Third generation synchrotron facilities such as the Diamond Light Source (DLS) have a wide range of experiments performed for a wide range of science fields. The DLS operates at energies up to 150 keV which introduces great challenges to radiation detector technology. This work focuses on the requirements that the detector technology faces for X-ray Absorption Fine Structure (XAFS) and powder diffraction experiments in I12 and I15 beam lines, respectively. A segmented HPGe demonstrator detector with in-built charge sensitive CUBE preamplifiers and a Schottky e- collection CdTe Medipix3RX detector systems were investigated to understand the underlying mechanisms that limit spectroscopic, imaging performances and stability and to find ways to overcome or minimise those limitations. The energy resolution and stability of the Ge demonstrator detector was found to have the required characteristics for XAFS measurements. Charge sharing was identified as a limiting factor to the resolution which is going to be addressed in the future development of a full detector system as well as reductions in electronic noise and cross-talk effects. The stability study of the Schottky CdTe Medipix3RX detector showed that polarization is highly dependent on temperature, irradiation duration and incoming flux. A new pixel behaviour called tri-phase (3-P) pixel was identified and a novel method for determining optimum operational conditions was developed. The use of the 3-P pixels as a criterion for depolarization resulted in a stable performance of the detector. Furthermore, the detector was applied in powder diffraction measurement at the I15 beam line and resulted in the detector diffraction pattern matching the simulated data. CdTe Medipix3RX and HEXITEC spectroscopic imaging detectors were applied in identification and discrimination of transitional metals for security application and K-edge subtraction for medical applications. The results showed that both detectors have potential

  19. Characteristics of phase transition and separation in a In-Ge-Sb-Te system

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sung Jin [Institute of Physics and Applied Physics, Yonsei University, Seoul 120-749 (Korea, Republic of); Jang, Moon Hyung [Department of Materials Science and Engineering, University of Pennsylvania, Philadelphia, PA 19104 (United States); Park, Seung-Jong [Institute of Physics and Applied Physics, Yonsei University, Seoul 120-749 (Korea, Republic of); Cho, Mann-Ho, E-mail: mh.cho@yonsei.ac.kr [Institute of Physics and Applied Physics, Yonsei University, Seoul 120-749 (Korea, Republic of); Ko, Dae-Hong [Department of Material Science and Engineering, Yonsei University, Seoul 120-749 (Korea, Republic of)

    2012-10-01

    Highlights: Black-Right-Pointing-Pointer InGeSbTe films were fabricated via co-deposition stoichiometric GST and IST targets. Black-Right-Pointing-Pointer As the amount of IST was increased in InGeSbTe, the value for V{sub th} and the phase transition temperature were increased. Black-Right-Pointing-Pointer The phase separation in InGeSbTe is caused by differences in the enthalpy change for formation and different atomic concentrations. - Abstract: In-doped GeSbTe films were deposited by ion beam sputtering deposition (IBSD) using Ge{sub 2}Sb{sub 2}Te{sub 5} (GST) and In{sub 3}Sb{sub 1}Te{sub 2} (IST) as targets. The phase change characteristics of the resulting films were then investigated by electrical measurements, including static testing, in situ 4-point R{sub s} measurements, X-ray diffraction (XRD), transmission electron microscopy (TEM) and Raman spectroscopy. The threshold voltage of the films increased, with increasing levels of IST. This phenomenon is consistent with the increased crystallization temperature in X-ray data and in situ 4-point R{sub s} data. In addition, in In{sub 28}Ge{sub 12}Sb{sub 26}Te{sub 34}, multiple V{sub th} values with a stepwise change are observed. The minimum time for the crystallization of InGeSbTe films was shorter than that for GST. X-ray data and Raman data for the crystalline structure show that phase separation to In{sub 2}Te{sub 3} occurred in all of the InGeSbTe samples after annealing at 350 Degree-Sign C. Moreover, in the case of InGeSbTe films with high concentrations of In (28 at.%), Sb phase separation was also observed. The observed phases indicate that the origin of the phase separation of InGeSbTe films is from the enthalpy change of formation and differences in Ge-Te, In-Te, Sb-Te, In-Sb and In-In bond energies.

  20. 21 CFR 880.6315 - Remote Medication Management System.

    Science.gov (United States)

    2010-04-01

    ... Miscellaneous Devices § 880.6315 Remote Medication Management System. (a) Identification. A remote medication..., and medication packaging. The system is intended to store the patient's prescribed medications in a... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Remote Medication Management System. 880.6315...

  1. Medical image information system 2001. Development of the medical image information system to risk management- Medical exposure management

    International Nuclear Information System (INIS)

    Kuranishi, Makoto; Kumagai, Michitomo; Shintani, Mitsuo

    2000-01-01

    This paper discusses the methods and systems for optimizing the following supplements 10 and 17 for national health and medical care. The supplements 10 and 17 of DICOM (digital imaging and communications in medicine) system, which is now under progress for the purpose to keep compatibility within medical image information system as an international standard, are important for making the cooperation between HIS (hospital information system)/RIS (radiation information system) and modality (imaging instruments). Supplement 10 concerns the system to send the information of patients and their orders through HIS/RIS to modality and 17, the information of modality performed procedure step (MPPS) to HIS/RIS. The latter defines to document patients' exposure, a part of which has not been recognized in Japan. Thus the medical information system can be useful for risk-management of medical exposure in future. (K.H.)

  2. Medical image information system 2001. Development of the medical image information system to risk management- Medical exposure management

    Energy Technology Data Exchange (ETDEWEB)

    Kuranishi, Makoto; Kumagai, Michitomo; Shintani, Mitsuo [Toyama Medical and Pharmaceutical Univ. (Japan). Hospital

    2000-12-01

    This paper discusses the methods and systems for optimizing the following supplements 10 and 17 for national health and medical care. The supplements 10 and 17 of DICOM (digital imaging and communications in medicine) system, which is now under progress for the purpose to keep compatibility within medical image information system as an international standard, are important for making the cooperation between HIS (hospital information system)/RIS (radiation information system) and modality (imaging instruments). Supplement 10 concerns the system to send the information of patients and their orders through HIS/RIS to modality and 17, the information of modality performed procedure step (MPPS) to HIS/RIS. The latter defines to document patients' exposure, a part of which has not been recognized in Japan. Thus the medical information system can be useful for risk-management of medical exposure in future. (K.H.)

  3. Improved Interactive Medical-Imaging System

    Science.gov (United States)

    Ross, Muriel D.; Twombly, Ian A.; Senger, Steven

    2003-01-01

    An improved computational-simulation system for interactive medical imaging has been invented. The system displays high-resolution, three-dimensional-appearing images of anatomical objects based on data acquired by such techniques as computed tomography (CT) and magnetic-resonance imaging (MRI). The system enables users to manipulate the data to obtain a variety of views for example, to display cross sections in specified planes or to rotate images about specified axes. Relative to prior such systems, this system offers enhanced capabilities for synthesizing images of surgical cuts and for collaboration by users at multiple, remote computing sites.

  4. Medical Information Management System (MIMS): A generalized interactive information system

    Science.gov (United States)

    Alterescu, S.; Friedman, C. A.; Hipkins, K. R.

    1975-01-01

    An interactive information system is described. It is a general purpose, free format system which offers immediate assistance where manipulation of large data bases is required. The medical area is a prime area of application. Examples of the system's operation, commentary on the examples, and a complete listing of the system program are included.

  5. A recommender system for medical imaging diagnostic.

    Science.gov (United States)

    Monteiro, Eriksson; Valente, Frederico; Costa, Carlos; Oliveira, José Luís

    2015-01-01

    The large volume of data captured daily in healthcare institutions is opening new and great perspectives about the best ways to use it towards improving clinical practice. In this paper we present a context-based recommender system to support medical imaging diagnostic. The system relies on data mining and context-based retrieval techniques to automatically lookup for relevant information that may help physicians in the diagnostic decision.

  6. GE/NOMADICS IN-WELL MONITORING SYSTEM FOR VERTICAL PROFILING OF DNAPL CONTAMINANTS

    Energy Technology Data Exchange (ETDEWEB)

    Ronald E. Shaffer; Radislav Potyralio; Joseph Salvo; Timothy Sivavec; Lloyd Salsman

    2003-04-01

    This report describes the Phase I effort to develop an Automated In Well Monitoring System (AIMS) for in situ detection of chlorinated volatile organic compounds such as trichloroethylene (TCE) and tetrachloroethylene (PCE) in groundwater. AIMS is composed of 3 primary components: (a) sensor probe, (b) instrument delivery system, and (c) communication/recharging station. The sensor probe utilizes an array of thickness shear mode (TSM) sensors coated with chemically-sensitive polymer films provides a low-cost, highly sensitive microsensor platform for detection and quantification. The instrument delivery system is used to position the sensor probe in 2 inch or larger groundwater monitoring wells. A communication/recharging station provides wireless battery recharging and communication to enable a fully automated system. A calibration curve for TCE in water was built using data collected in the laboratory. The detection limit of the sensor probe was 6.7 ppb ({micro}g/L) for TCE in water. A preliminary field test was conducted at a GE remediation location and a pilot field test was performed at the DOE Savannah River Site (SRS). The AIMS system was demonstrated in an uncontaminated (i.e., ''clean'') 2-inch well and in a 4-inch well containing 163.5 ppb of TCE. Repeat measurements at the two wells indicated excellent day-to-day reproducibility. Significant differences in the sensor responses were noted between the two types of wells but they did not closely match the laboratory calibration data. The robustness of the system presented numerous challenges for field work and limited the scope of the SRS pilot field test. However, the unique combination of trace detection (detection limits near the MCL, minimum concentration level) and size (operations in 2-inch or larger groundwater wells) is demonstration of the promise of this technology for long-term monitoring (LTM) applications or rapid site characterization. Using the lessons learned from the

  7. Safety of the medical gas pipeline system

    Directory of Open Access Journals (Sweden)

    Sushmita Sarangi

    2018-01-01

    Full Text Available Medical gases are nowadays being used for a number of diverse clinical applications and its piped delivery is a landmark achievement in the field of patient care. Patient safety is of paramount importance in the design, installation, commissioning, and operation of medical gas pipeline systems (MGPS. The system has to be operational round the clock, with practically zero downtime and its failure can be fatal if not restored at the earliest. There is a lack of awareness among the clinicians regarding the medico-legal aspect involved with the MGPS. It is a highly technical field; hence, an in-depth knowledge is a must to ensure safety with the system.

  8. Applications of a Ga-68/Ge-68 generator system to brain imaging using a multiwire proportional chamber positron camera

    International Nuclear Information System (INIS)

    Hattner, R.S.; Lim, C.B.; Swann, S.J.; Kaufman, L.; Chu, D.; Perez-Mendez, V.

    1976-01-01

    A Ge-68/Ga-68 generator system has been applied to brain imaging in conjunction with a novel coincidence detection based positron camera. The camera consists of two opposed large area multiwire proportional chamber (MWPC) detectors interfaced to multichannel lead converter plates. Event localization is effected of delay lines. Ten patients with brain lesions have been studied 1-2 hours after the administration of Ga-68 formulated as DTPA. The images were compared to conventional brain scans, and to x-ray section scans (CAT). The positron studies have shown significant mitigation of confusing superficial activity resulting from craniotomy compared to conventional brain scans. Central necrosis of lesions observed in positron images, but not in the conventional scans has been confirmed in CAT. The economy of MWPC positron cameras combined with the ideal characteristics of the Ge-68/Ga-68 generator promise a cost efficient imaging system for the future

  9. Communication system and spectral analysis for Ge-Li and GeHp detectors; Sistema de comunicaciones y analisis de espectros para detectores Ge-Li y GeHp

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, J; Castano, P; Bonino, A D; Righetti, M A

    1991-12-31

    An integral communication and spectral analysis system (SICADE) was developed and implemented to satisfy the need to optimize and automate the measurement system used in Atucha I nuclear power plant for the activity in the primary loop`s water extracted by the TV system. The importance of these measurements is based on the fact that from the spectrometric analysis of the samples extracted, the Iodines-GN and Iodines-Iodines relations, which allow to detect the presence of deficient fuel elements, are calculated. The system developed is based on two modules integrated in a unique set commanded by the operators through the screen dialogue. (Author). [Espanol] Dada la necesidad de optimizar y automatizar el sistema de medicion utilizado en la Central Nuclear Atucha I para la actividad en el agua del circuito primario extraida a traves del sistema TV se desarrollo e implemento un sistema integral de Comunicacion y Analisis de espectros (SICADE). La importancia de estas mediciones radica en el hecho que del analisis espectrometrico de las muestras extraidas se calculan las relaciones entre Iodos-GN e Iodos-Iodos que permiten detectar la presencia de elementos combustibles fallados. El sistema desarrollado esta basado en dos modulos integrados en un unico conjunto comandado por el operador a traves del dialogo por pantalla. (Autor).

  10. Plant Engineering and Construction System with Knowledge Management: A Case Study in NPP Construction in Hitachi-GE NE

    International Nuclear Information System (INIS)

    Mochida, T.; Hamamoto, M.; Nakamitsu, N.

    2016-01-01

    Full text: Hitachi-GE Nuclear Energy, Ltd. (HGNE) has more than 40 years BWR plants construction experience. The company continues to develop plant engineering system and plant construction systems based on the experience and the lessons learned. Currently, these systems are integrated in a variety of knowledge bases using the latest information technology (IT). Their performance is continuously validated in the recent NPP constructions. Typical examples are shown as case studies for knowledge management. These plant engineering and construction management systems are essential to achieve the on-time and on-budget-goals in NPP construction projects. (author

  11. Preliminary application in teaching of medical imaging with picture archiving and communication systems

    International Nuclear Information System (INIS)

    Wei Yuqing; Hu Jian; Wang Xuejian; Cao Jun; Tong Juan; Shen Guiquan; Luo Min; Luo Song

    2003-01-01

    Objective: To evaluate PACS (picture archiving and communication systems) in the teaching of medical imaging. Methods: Large screen multimedia reading room and electronic study room were built with GE PACS and Angel RIS (radiology information system) and end-term picture-word work-station. Pictures and words of PACS were unloaded directly for teaching and teaching image bank and test image bank. Results: Large screen multimedia reading room, classroom, and electronic study room were built successfully. Valuable information of nearly 5000 patients in the teaching imaging bank of PACS was accumulated. Classic medical imaging teaching mode was changed. Real-time and multi-mode teaching were realized, and teaching effect was greatly improved. The PACS-based teaching model was accepted pleasantly by students. Conclusion: PACS is very useful to improve the teaching quality of medical imaging and it is worth to popularize

  12. Multi-channel medical imaging system

    Science.gov (United States)

    Frangioni, John V

    2013-12-31

    A medical imaging system provides simultaneous rendering of visible light and fluorescent images. The system may employ dyes in a small-molecule form that remain in the subject's blood stream for several minutes, allowing real-time imaging of the subject's circulatory system superimposed upon a conventional, visible light image of the subject. The system may provide an excitation light source to excite the fluorescent substance and a visible light source for general illumination within the same optical guide used to capture images. The system may be configured for use in open surgical procedures by providing an operating area that is closed to ambient light. The systems described herein provide two or more diagnostic imaging channels for capture of multiple, concurrent diagnostic images and may be used where a visible light image may be usefully supplemented by two or more images that are independently marked for functional interest.

  13. First principles investigation of interaction between impurity atom (Si, Ge, Sn) and carbon atom in diamond-like carbon system

    International Nuclear Information System (INIS)

    Li, Xiaowei; Wang, Aiying; Lee, Kwang-Ryeol

    2012-01-01

    The interaction between impurity atom (Si, Ge, and Sn) and carbon atom in diamond-like carbon (DLC) system was investigated by the first principles simulation method based on the density functional theory. The tetrahedral configuration was selected as the calculation model for simplicity. When the bond angle varied in a range of 90°–130° from the equivalent state of 109.471°, the distortion energy and the electronic structures including charge density of the highest occupied molecular orbital (HOMO) and partial density of state (PDOS) in the different systems were calculated. The results showed that the addition of Si, Ge and Sn atom into amorphous carbon matrix significantly decreased the distortion energy of the system as the bond angles deviated from the equilibrium one. Further studies of the HOMO and PDOS indicated that the weak covalent bond between Si(Ge, Sn) and C atoms was formed with the decreased strength and directionality, which were influenced by the electronegative difference. These results implied that the electron transfer behavior at the junction of carbon nano-devices could be tailored by the impurity element, and the compressive stress in DLC films could be reduced by the incorporation of Si, Ge and Sn because of the formation of weaker covalent bonds. - Highlights: ►Distortion energy after bond angle distortion was decreased comparing with C-C unit. ►The weak covalent bond was formed between impurity atoms and corner carbon atoms. ►Observed electron transfer behavior affected the strength and directionality of bond. ►Reduction of strength and directionality of bond contributed to small energy change.

  14. The medical care system of Hungary.

    Science.gov (United States)

    Raffel, N K; Raffel, M W

    1988-01-01

    Medical care in Hungary has made significant progress since World War II in spite of other social priorities which have limited financial support of the health system. A shortage of hard currency in a high technological era is now having a particularly severe adverse impact on further development. Decentralized administration and local finance have, however, provided some room for progress. Preventive efforts are hampered by a deeply entrenched life style which is not conducive to improving the population's health status.

  15. Military Medical Revolution: Military Trauma System

    Science.gov (United States)

    2012-01-01

    receive state-of-the-art physical therapy and occupational therapy , in- cluding demanding and challenging sports equipment and virtual reality systems...Knudson MM. Into the theater: perspectives from a civilian trauma sur- geon’s visit to the combat support hospital in Balad, Iraq. Bull Am Coll Surg...following type III open tibia fracture . J Orthop Trauma. 2012;26:43 47. 52. U.S Army Medical Research and Materiel Command. Armed Forces In- stitute of

  16. Structure and superconducting properties of Nb3Ge prepared in a UHV system

    International Nuclear Information System (INIS)

    Habermeier, H.U.; Stuttgart Univ.

    1981-01-01

    Nb 3 Ge films are prepared by coevaporation of Nb and Ge under well defined and controlled conditions. The formation of the A15 Nb 3 Ge phase is studied by varying the processing parameters - composition, deposition temperature, and impurity gas background - systematically. Single phase samples with Tsub(c) onsets as high as 21.5 K and lattice parameters of 0.5148 nm only be obtained in an environment with no added impurities and a Ge concentration of 23.8 at%. Oxygen as impurity gas enhances Tsub(c) slightly in samples of the optimal composition, whereas hydrogen as impurity gas does not affect the formation and the Tsub(c) of the A15 phase at all. The structure, (lattice parameters, grain sizes, and phases present) and the superconducting properties (Tsub(c), Hsub(c2)(0)) of the samples show a systematic correlation of the preparation parameters and the physical properties. The experimental results are explained qualitatively within the frame of the linear chain model of A15 superconductors combined with the introduction of anti-site defects. (author)

  17. Development of {sup 77}Ge/{sup 77}As parent-daughter system for periodic removal of {sup 77}As for environmental sanitation and biochemical purposes

    Energy Technology Data Exchange (ETDEWEB)

    Olah, Zita; Doczi, Rita [Budapest Univ. of Technology and Economics (Hungary). Inst. of Nuclear Techniques; Szuecs, Zoltan [Hungarian Academy of Sciences, Debrecen (Hungary). Inst. for Nuclear Research; Varga, Zoltan [Hungarian Academy of Sciences, Budapest (Hungary). Research Centre for Natural Sciences

    2015-07-01

    A simple method was developed for the separation of radioactive {sup 77}As from neutron irradiated natural GeO{sub 2} samples for environmental and biochemical studies. The method is based on the volatility of GeCl{sub 4}. The GeCl{sub 4} was co-evaporated from the reaction mixture with an azeotropic mixture of HCl and water, and immediately condensed into a separate finger part of the special glass apparatus which was cooled by liquid nitrogen. By inverting the room temperature and the deep frozen parts of the glass equipment after three half-lives of the {sup 77}Ge the separation process can be repetitive, getting a special type of {sup 77}Ge/{sup 77}As parent-daughter system. The radionuclidic purity of the remaining As fraction was found to be 99.95%. Its yield, however, drastically decreased in the second and subsequent separations.

  18. Development of 77Ge/77As parent-daughter system for periodic removal of 77As for environmental sanitation and biochemical purposes

    International Nuclear Information System (INIS)

    Olah, Zita; Doczi, Rita; Szuecs, Zoltan; Varga, Zoltan

    2015-01-01

    A simple method was developed for the separation of radioactive 77 As from neutron irradiated natural GeO 2 samples for environmental and biochemical studies. The method is based on the volatility of GeCl 4 . The GeCl 4 was co-evaporated from the reaction mixture with an azeotropic mixture of HCl and water, and immediately condensed into a separate finger part of the special glass apparatus which was cooled by liquid nitrogen. By inverting the room temperature and the deep frozen parts of the glass equipment after three half-lives of the 77 Ge the separation process can be repetitive, getting a special type of 77 Ge/ 77 As parent-daughter system. The radionuclidic purity of the remaining As fraction was found to be 99.95%. Its yield, however, drastically decreased in the second and subsequent separations.

  19. Study of the slope-mass correlation in the low mass K. pi pi. system. [13 GeV/c

    Energy Technology Data Exchange (ETDEWEB)

    Carnegie, R K; Cashmore, R J; Davier, M; Dunwoodie, W; Lasinski, T A; Leith, D W.G.S.; Stroynowski, R; Williams, S H [Stanford Linear Accelerator Center, Calif. (USA)

    1976-07-19

    The shape of the four-momentum transfer t' distribution in the reactions K/sup + -/p..-->..K/sup + -/..pi../sup +/..pi../sup -/p at 13 GeV/c is studied for various partial waves as a function of the K..pi pi.. mass. Strong variation of the slope with effective mass is observed for the dominant Jsup(P) = 1/sup +/ waves. For natural parity exchange it is found that, for K..pi pi.. masses up to 1.6 GeV, the slope of the t' distribution is decreasing with increasing spin of the excited system, B/sub 0/->B/sub 1/+>B/sub 2/+.

  20. Measurement of K-sub(p) 4.2 GeV/c interactions with a PEPR Vertex Guidance System

    International Nuclear Information System (INIS)

    Schouten, T.E.

    1977-01-01

    For the K - sub(p) 4.2 GeV/c experiment more than three million bubble chamber pictures were taken and analyzed by a collaboration of laboratories in CERN, Amsterdam, Oxford and Nijmegen. The analysis of such a large amount of pictures requires a large degree of automatization in the processing chain. In this thesis a description is presented of the hardware and software of a pattern recognition system for the automatic measurement of bubble chamber pictures: the PEPR Vertex Guidance system. PEPR stands for Precision Encoding and Pattern Recognition. The results of this system are analyzed in terms of speed, throughput, accuracy and efficiency of the measurements

  1. [Design and application of implantable medical device information management system].

    Science.gov (United States)

    Cao, Shaoping; Yin, Chunguang; Zhao, Zhenying

    2013-03-01

    Through the establishment of implantable medical device information management system, with the aid of the regional joint sharing of resources, we further enhance the implantable medical device traceability management level, strengthen quality management, control of medical risk.

  2. Multispectral system for medical fluorescence imaging

    International Nuclear Information System (INIS)

    Andersson, P.S.; Montan, S.; Svanberg, S.

    1987-01-01

    The principles of a powerful multicolor imaging system for tissue fluorescence diagnostics are discussed. Four individually spectrally filtered images are formed on a matrix detector by means of a split-mirror arrangement. The four images are processed in a computer, pixel by pixel, by means of mathematical operations, leading to an optimized contrast image, which enhances a selected feature. The system is being developed primarily for medical fluorescence imaging, but has wide applications in fluorescence, reflectance, and transmission monitoring related to a wide range of industrial and environmental problems. The system operation is described for the case of linear imaging on a diode array detector. Laser-induced fluorescence is used for cancer tumor and arteriosclerotic plaque demarcation using the contrast enhancement capabilities of this imaging system. Further examples of applications include fluorescing minerals and flames

  3. 76 FR 59167 - Siemens Medical Solutions USA, Inc., Oncology Care Systems Division, Concord, CA; Siemens Medical...

    Science.gov (United States)

    2011-09-23

    ... Medical Solutions USA, Inc., Oncology Care Systems Division, Concord, CA; Siemens Medical Solutions USA... Solutions USA, Inc. (Siemens), Oncology Care Systems Division, Concord, California (subject firm). The...., Oncology Care Systems Division, Concord, California (TA-W-73,158) and Siemens Medical Solutions USA, Inc...

  4. Hydrothermal crystallization in the KOH-TiO2-GeO2-H2O system at 500 deg C and 0.1 GPa

    International Nuclear Information System (INIS)

    Ilyushin, G.D.

    2003-01-01

    The identification of structural phases and crystallochemical analysis of phases in a KOH-TiO 2 -GeO 2 -H 2 O system under conditions of high temperatures and pressures are performed. A comparison is made with earlier obtained results for a system of KOH-GeO 2 (quartz-like structure)-H 2 O. It is established that K 2 Ti 6 O 13 skeleton potassium titanate is a basic phase in the system of KOH-TiO 2 -GeO 2 -H 2 O at 500 deg C and 0.1 GPa within a wide range of varying TiO 2 :GeO 2 and KOH concentrations [ru

  5. 20 CFR 405.10 - Medical and Vocational Expert System.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Medical and Vocational Expert System. 405.10... Vocational Expert System. (a) General. The Medical and Vocational Expert System is comprised of the Medical... Vocational Expert System. (3) Experts who provide evidence at your request. Experts whom you ask to provide...

  6. Mechanical relaxation in chalcogenide glasses of the Ge-As-S system

    International Nuclear Information System (INIS)

    Bilanych, V.S.; Melnychenko, T.D.; Rizak, V.M.; Makauz, I.I.

    2006-01-01

    The temperature and frequency-related dependences of the internal friction and the shear modulus in Ge x As 40-x S 60 glasses have been studied. The maxima of internal friction of both the relaxation and non relaxation types have been found in the low-temperature range. A relaxation maximum has been revealed in the vitrification region, and its parameters have been determined. Possible mechanisms of these processes have been discussed

  7. Mass Medication Clinic (MMC) Patient Medical Assistant (PMA) System Training Initiative

    Science.gov (United States)

    2007-06-01

    AD_________________ Award Number: W81XWH-06-2-0045 TITLE: Mass Medication Clinic (MMC) Patient ...SUBTITLE 5a. CONTRACT NUMBER Mass Medication Clinic (MMC) Patient Medical Assistant (PMA) System Training Initiative 5b. GRANT NUMBER W81XWH-06-2...sections will describe the events, results, and accomplishments of this study. With validation through this project the Patient Medical Assistant

  8. The Fresenius Medical Care home hemodialysis system.

    Science.gov (United States)

    Schlaeper, Christian; Diaz-Buxo, Jose A

    2004-01-01

    The Fresenius Medical Care home dialysis system consists of a newly designed machine, a central monitoring system, a state-of-the-art reverse osmosis module, ultrapure water, and all the services associated with a successful implementation. The 2008K@home hemodialysis machine has the flexibility to accommodate the changing needs of the home hemodialysis patient and is well suited to deliver short daily or prolonged nocturnal dialysis using a broad range of dialysate flows and concentrates. The intuitive design, large graphic illustrations, and step-by-step tutorial make this equipment very user friendly. Patient safety is assured by the use of hydraulic systems with a long history of reliability, smart alarm algorithms, and advanced electronic monitoring. To further patient comfort with their safety at home, the 2008K@home is enabled to communicate with the newly designed iCare remote monitoring system. The Aquaboss Smart reverse osmosis (RO) system is compact, quiet, highly efficient, and offers an improved hygienic design. The RO module reduces water consumption by monitoring the water flow of the dialysis system and adjusting water production accordingly. The Diasafe Plus filter provides ultrapure water, known for its long-term benefits. This comprehensive approach includes planning, installation, technical and clinical support, and customer service.

  9. Medical systems in the last half century

    International Nuclear Information System (INIS)

    Kramer, C.; Botden, P.J.M.

    1986-01-01

    An overview is presented of the Philips activities in the field of medical systems. They began with the repair of X-ray tubes, which could no longer be sent abroad to the manufacturers during World War I. As a result, Philips soon embarked upon its own development and production of X-ray tubes, power-supply generators, and equipment for patient support and diagnosis. Typical contributions included the rotating anode, which permitted a considerable increase in power and the first ideas on an X-ray image intensifier, which greatly increased the range of capabilities of the radiologist and also reduced very considerably the dose of radiation administered to the patient. The activities in medical electronics grew strongly at first, but are not now pursued, so that Philips can concentrate on systems for medical image diagnosis and radiation therapy. Developments in this area include the gamma camera and the use of ultrasound. Equipment for radiotherapy includes, apart from the well-established X-ray tubes, equipment using radioactive cobalt, linear electron accelerators and a sealed-off neutron tube. The combination of image intensifier with television techniques not only gave the radiologist much more freedom but also led to digitization of the X-ray image. Digitization made i0305ssible to use computer techniques for image processing, which led to computerized tomography (the CT scanner) and to digital vascular imaging, and also to automated storage of X-ray images. One of the latest and very promising imaging techniques (MR) makes use of nuclear magnetic resonance. (Auth.)

  10. The Integrated Medical Model: A Risk Assessment and Decision Support Tool for Space Flight Medical Systems

    Science.gov (United States)

    Kerstman, Eric; Minard, Charles; Saile, Lynn; deCarvalho, Mary Freire; Myers, Jerry; Walton, Marlei; Butler, Douglas; Iyengar, Sriram; Johnson-Throop, Kathy; Baumann, David

    2009-01-01

    The Integrated Medical Model (IMM) is a decision support tool that is useful to mission planners and medical system designers in assessing risks and designing medical systems for space flight missions. The IMM provides an evidence based approach for optimizing medical resources and minimizing risks within space flight operational constraints. The mathematical relationships among mission and crew profiles, medical condition incidence data, in-flight medical resources, potential crew functional impairments, and clinical end-states are established to determine probable mission outcomes. Stochastic computational methods are used to forecast probability distributions of crew health and medical resource utilization, as well as estimates of medical evacuation and loss of crew life. The IMM has been used in support of the International Space Station (ISS) medical kit redesign, the medical component of the ISS Probabilistic Risk Assessment, and the development of the Constellation Medical Conditions List. The IMM also will be used to refine medical requirements for the Constellation program. The IMM outputs for ISS and Constellation design reference missions will be presented to demonstrate the potential of the IMM in assessing risks, planning missions, and designing medical systems. The implementation of the IMM verification and validation plan will be reviewed. Additional planned capabilities of the IMM, including optimization techniques and the inclusion of a mission timeline, will be discussed. Given the space flight constraints of mass, volume, and crew medical training, the IMM is a valuable risk assessment and decision support tool for medical system design and mission planning.

  11. Stretchable bioelectronics for medical devices and systems

    CERN Document Server

    Ghaffari, Roozbeh; Kim, Dae-Hyeong

    2016-01-01

    This book highlights recent advances in soft and stretchable biointegrated electronics. A renowned group of authors address key ideas in the materials, processes, mechanics, and devices of soft and stretchable electronics; the wearable electronics systems; and bioinspired and implantable biomedical electronics. Among the topics discussed are liquid metals, stretchable and flexible energy sources, skin-like devices, in vitro neural recording, and more. Special focus is given to recent advances in extremely soft and stretchable bio-inspired electronics with real-world clinical studies that validate the technology. Foundational theoretical and experimental aspects are also covered in relation to the design and application of these biointegrated electronics systems. This is an ideal book for researchers, engineers, and industry professionals involved in developing healthcare devices, medical tools and related instruments relevant to various clinical practices.

  12. Radiation monitoring system in medical facilities

    International Nuclear Information System (INIS)

    Matsuno, Kiyoshi

    1981-01-01

    (1) RI selective liquid effluent monitor is, in many cases, used at medical facilities to obtain data for density of radioactivity of six radionuclides. In comparison with the conventional gross measuring systems, over-evaluation is less, and the monitor is more practical. (2) Preventive monitor for loss of radium needle is a system which prevents missing of radium needle at a flush-toilet in radium treatment wards, and this monitor is capable of sensing a drop-off of radium needle of 0.5 mCi (minimum). (3) Short-lived positron gas measuring device belongs to a BABY CYCLOTRON installed in a hospital, and this device is used to measure density of radioactivity, radioactive impurity and chemical impurity of produced radioactive gas. (author)

  13. Enhancements in wind energy technology and system integration by the example of the new GE 2.5-120 WTG

    International Nuclear Information System (INIS)

    Wachtel, Stephan

    2013-01-01

    The development of the GE 2.5-120 WTG demonstrates in an exemplary manner how the divagating requirements for cost reduction and meeting increased grid connection requirements can be fulfilled. New developments enable utilisation of a rotor with 120 m diameter leading to an increase in efficiency of up to 25 % and annual energy production of up to 15 %. This further development shows that today's but also future technical and economic requirements for wind power and its integration into the power system can be met. (orig.)

  14. Gd5(SixGe1−x)4 system – updated phase diagram

    International Nuclear Information System (INIS)

    Melikhov, Yevgen; Hadimani, R.L.; Raghunathan, Arun

    2015-01-01

    Gd 5 (Si x Ge 1−x ) 4 for 0.41Ge 1−x ) 4 for 0.41Ge 1−x ) 4 for 0.41

  15. A Data Acquisition System for Medical Imaging

    International Nuclear Information System (INIS)

    Abellan, Carlos; Cachemiche, Jean-Pierre; Rethore, Frederic; Morel, Christian

    2013-06-01

    A data acquisition system for medical imaging applications is presented. Developed at CPPM, it provides high performance generic data acquisition and processing capabilities. The DAQ system is based on the PICMG xTCA standard and is composed of 1 up to 10 cards in a single rack, each one with 2 Altera Stratix IV FPGAs and a Fast Mezzanine Connector (FMC). Several mezzanines have been produced, each one with different functionalities. Some examples are: a mezzanine capable of receiving 36 optical fibres with up to 180 Gbps sustained data rates or a mezzanine with 12 x 5 Gbps input links, 12 x 5 Gbps output links and an SFP+ connector for control purposes. Several rack sizes are also available, thus making the system scalable from a one card desktop system useful for development purpose up to a full featured rack mounted DAQ for high end applications. Depending on the application, boards may exchange data at speeds of up to 25.6 Gbps bidirectional sustained rates in a double star topology through back-plane connections. Also, front panel optical fibres can be used when higher rates are required by the application. The system may be controlled by a standard Ethernet connection, thus providing easy integration with control computers and avoiding the need for drivers. Two control systems are foreseen. A Socket connection provides easy interaction with automation software regardless of the operating system used for the control PC. Moreover a web server may run on the Envision cards and provide an easy intuitive user interface. The system and its different components will be introduced. Some preliminary measurements with high speed signal links will be presented as well as the signal conditioning used to allow these rates. (authors)

  16. GE-CMU: Description of the Shogun System Used for MUC-5

    Science.gov (United States)

    1993-01-01

    points , anyway. In this case, the Japanese text says that the tie-up will be selling a new product called " hyu -man " . 112 70 60 — JJ V JME n JJV n JM...50 60 70 Recal l Figure 3 : GE-CMU Results for MUC-5/TIPSTER 24-month benchmar k SHOGUN correctly spots this and assumes that whatever " hyu -man...34 is will be wholesale sales with code 50 . The analyst infers from the context that " hyu -man" is an insurance product, so the actual industry type i

  17. Experimental investigation of densification of powdered A15 phase in the system Nb--Al--Ge

    International Nuclear Information System (INIS)

    Modi, D.P.

    1976-02-01

    An investigation of the densification of precompounded powder of the A15 phase Nb 3 (Al,Ge) was made. The influence of various parameters such as additives, temperature, pressure and time in sintering of this material was studied. Since cold pressing followed by sintering did not produce sufficient density, the hot pressing technique was used. By hot pressing at 1450 0 C for 1 / 2 hour under 6 ksi pressure, about 95 percent densification was achieved. Results provide information that could lead to the development of a viable process for producing superconductors based on this compound. 14 figures, 17 references

  18. Intelligent Medical Systems for Aerospace Emergency Medical Services

    Science.gov (United States)

    Epler, John; Zimmer, Gary

    2004-01-01

    The purpose of this project is to develop a portable, hands free device for emergency medical decision support to be used in remote or confined settings by non-physician providers. Phase I of the project will entail the development of a voice-activated device that will utilize an intelligent algorithm to provide guidance in establishing an airway in an emergency situation. The interactive, hands free software will process requests for assistance based on verbal prompts and algorithmic decision-making. The device will allow the CMO to attend to the patient while receiving verbal instruction. The software will also feature graphic representations where it is felt helpful in aiding in procedures. We will also develop a training program to orient users to the algorithmic approach, the use of the hardware and specific procedural considerations. We will validate the efficacy of this mode of technology application by testing in the Johns Hopkins Department of Emergency Medicine. Phase I of the project will focus on the validation of the proposed algorithm, testing and validation of the decision making tool and modifications of medical equipment. In Phase 11, we will produce the first generation software for hands-free, interactive medical decision making for use in acute care environments.

  19. Sensitivity of a low energy Ge detector system for in vivo monitoring in the framework of ICRP 78 applications.

    Science.gov (United States)

    Lopez, M A; Navarro, T

    2003-01-01

    In in vivo detection of internal contamination by actinides the minimum detectable activities (MDAs) correspond to significant doses, so the sensitivity of the detection system is the key to establishing adequate individual monitoring programmes for internal exposure to these radionuclides. The whole body counting (WBC) faculty at CIEMAT uses a low-energy Ge detector system with different available counting geometries to estimate the retention of actinides in the lungs and evaluate 125I in thyroid and 241Am in bone (skull and knee). A study of the factors and uncertainties involved in estimations of MDA is presented for lung and thyroid monitoring. The dependence of detection limits on counting efficiency in the measurement of low-energy emitters in the lungs has been carefully studied, carrying out a comparison among different biometric equations obtained by ultrasound techniques for estimations of chest wall thickness. Dosimetric implications of the estimated MDAs are taken into account in the framework of ICRP 78 application and considering Spanish regulations. The main interest in lung measurements is for the assessment of occupational exposure. This work confirms the low-energy Ge detector system to be an adequate in vivo technique for the routine monitoring of internal exposure to most insoluble uranium compounds (detection of 3% enriched uranium in lungs), and also to be useful in special monitoring programmes or in the case of incidents when the detection of 241Am is required.

  20. Study on crystallization kinetics and phase evolution in Li2O-Al2O3-GeO2-P2O5 glass-ceramics system

    Science.gov (United States)

    Das, Anurup; Dixit, Anupam; Goswami, Madhumita; Mythili, R.; Hajra, R. N.

    2018-04-01

    To address the safety issues related to liquid electrolyte and improve the battery performance, Solid State Electrolytes (SSEs) are now in frontier area of research interest. We report here synthesis of Li-SSE based on Li2O-Al2O3-GeO2-P2O5 (LAGP) system with NASICON structure. Glass sample with nominal composition Li1.5Al0.5Ge1.5P2.5Si0.5O12 was prepared by melt-quenching technique. Non-isothermal crystallization kinetics was studied using DSC and activation energy of crystallisation was calculated to be ˜ 246 kJ/mol using Kissinger's equation. XRD of heat treated samples show the formation of required LiGe2(PO4)3 phase along with other minor phases. Compositional analysis using SEM-EDX confirms enrichment of Ge and Si along the grain boundaries.

  1. 76 FR 8637 - Medical Devices; Medical Device Data Systems

    Science.gov (United States)

    2011-02-15

    ....2100), or a picture archiving and communications system (PACS) classified under Sec. 892.2050 (21 CFR.... Because MDDS systems are so varied and these systems and their communication protocols change frequently... transfer or communication function of MDDS, however, the reference to the ``exchange'' function was removed...

  2. A multinational study to develop universal standardization of whole-body bone density and composition using GE Healthcare Lunar and Hologic DXA systems.

    Science.gov (United States)

    Shepherd, John A; Fan, Bo; Lu, Ying; Wu, Xiao P; Wacker, Wynn K; Ergun, David L; Levine, Michael A

    2012-10-01

    Dual-energy x-ray absorptiometry (DXA) is used to assess bone mineral density (BMD) and body composition, but measurements vary among instruments from different manufacturers. We sought to develop cross-calibration equations for whole-body bone density and composition derived using GE Healthcare Lunar and Hologic DXA systems. This multinational study recruited 199 adult and pediatric participants from a site in the US (n = 40, ages 6 through 16 years) and one in China (n = 159, ages 5 through 81 years). The mean age of the participants was 44.2 years. Each participant was scanned on both GE Healthcare Lunar and Hologic Discovery or Delphi DXA systems on the same day (US) or within 1 week (China) and all scans were centrally analyzed by a single technologist using GE Healthcare Lunar Encore version 14.0 and Hologic Apex version 3.0. Paired t-tests were used to test the results differences between the systems. Multiple regression and Deming regressions were used to derive the cross-conversion equations between the GE Healthcare Lunar and Hologic whole-body scans. Bone and soft tissue measures were highly correlated between the GE Healthcare Lunar and Hologic and systems, with r ranging from 0.96 percent fat [PFAT] to 0.98 (BMC). Significant differences were found between the two systems, with average absolute differences for PFAT, BMC, and BMD of 1.4%, 176.8 g and 0.013 g/cm(2) , respectively. After cross-calibration, no significant differences remained between GE Healthcare Lunar measured results and the results converted from Hologic. The equations we derived reduce differences between BMD and body composition as determined by GE Healthcare Lunar and Hologic systems and will facilitate combining study results in clinical or epidemiological studies. Copyright © 2012 American Society for Bone and Mineral Research.

  3. A DBMS-based medical teleconferencing system.

    Science.gov (United States)

    Chun, J; Kim, H; Lee, S; Choi, J; Cho, H

    2001-01-01

    This article presents the design of a medical teleconferencing system that is integrated with a multimedia patient database and incorporates easy-to-use tools and functions to effectively support collaborative work between physicians in remote locations. The design provides a virtual workspace that allows physicians to collectively view various kinds of patient data. By integrating the teleconferencing function into this workspace, physicians are able to conduct conferences using the same interface and have real-time access to the database during conference sessions. The authors have implemented a prototype based on this design. The prototype uses a high-speed network test bed and a manually created substitute for the integrated patient database.

  4. [Application of information management system about medical equipment].

    Science.gov (United States)

    Hang, Jianjin; Zhang, Chaoqun; Wu, Xiang-Yang

    2011-05-01

    Based on the practice of workflow, information management system about medical equipment was developed and its functions such as gathering, browsing, inquiring and counting were introduced. With dynamic and complete case management of medical equipment, the system improved the management of medical equipment.

  5. Estimation of critical thickness of Stranski-Krastanow transition in GeSi/Sn/Si system

    Science.gov (United States)

    Lozovoy, K. A.; Pishchagin, A. A.; Kokhanenko, A. P.; Voitsekhovskii, A. V.

    2017-11-01

    In this paper Stranski-Krastanow growth of Ge x Si1-x epitaxial layers on the Si(001) surface with pre-deposited tin layer with the thickness less than 1 ML is considered. For the calculations of critical thickness of transition from 2D to 3D growth in this paper a theoretical model based on general nucleation theory is used. This model is specified by taking into account dependencies of elastic modulus, lattices mismatch and surface energy of side facet on the composition x, as well as change in the adatoms diffusion coefficient and surface energy of the substrate in the presence of tin. As a result, dependencies of critical thickness of Stranski-Krastanow transition on compositon x and temperature are obtained. The simulated results are in a good agreement with experimentally observed results.

  6. Studies of a Target System for a 4-MW, 24-GeV Proton Beam

    CERN Multimedia

    2002-01-01

    We propose to perform a proof-of-principle test of a target station suitable for a Neutrino Factory or Muon Collider source using a 24-GeV proton beam incident on a target consisting of a free mercury jet that is inside a 15- T capture solenoid magnet. This test could be performed in the TT2A tunnel of the nTOF proton line (upstream of the spallation target). The tests would require only $\\approx$ 100 fast-extracted pulses of full PS intensity, delivered in a pulse-on-demand mode of operation over about 2 weeks. The main piece of apparatus is the LN2-precooled, 15- T copper magnet of total volume slightly over 1 m$^{3}$ with a 15-cm-diameter warm bore. The principle diagnostic is a high-speed optical camera. The mercury jet is part of a closed mercury loop that includes an insert into the bore of the magnet.

  7. National Health and Nutrition Examination Survey whole-body dual-energy X-ray absorptiometry reference data for GE Lunar systems.

    Science.gov (United States)

    Fan, Bo; Shepherd, John A; Levine, Michael A; Steinberg, Dee; Wacker, Wynn; Barden, Howard S; Ergun, David; Wu, Xin P

    2014-01-01

    The National Health and Nutrition Examination Survey (NHANES 1999-2004) includes adult and pediatric comparisons for total body bone and body composition results. Because dual-energy x-ray absorptiometry (DXA) measurements from different manufacturers are not standardized, NHANES reference values currently are applicable only to a single make and model of Hologic DXA system. The purpose of this study was to derive body composition reference curves for GE Healthcare Lunar DXA systems. Published values from the NHANES 1999-2004 survey were acquired from the Centers for Disease Control and Prevention website. Using previously reported cross-calibration equations between Hologic and GE-Lunar, we converted the total body and regional bone and soft-tissue measurements from NHANES 1999-2004 to GE-Lunar values. The LMS (LmsChartMaker Pro Version 3.5) curve fitting method was used to generate GE-Lunar reference curves. Separate curves were generated for each sex and ethnicity. The reference curves were also divided into pediatric (≤20 years old) and adult (>20 years old) groups. Adult reference curves were derived as a function of age. Additional relationships of pediatric DXA values were derived as a function of height, lean mass, and bone area. Robustness was tested between Hologic and GE-Lunar Z-score values. The NHANES 1999-2004 survey included a sample of 20,672 participants' (9630 female) DXA scans. A total of 8056 participants were younger than 20 yr and were included in the pediatric reference data set. Participants enrolled in the study who weighed more than 136 kg (over scanner table limit) were excluded. The average Z-scores comparing the new GE-Lunar reference curves are close to zero, and the standard deviation of the Z-scores are close to one for all variables. As expected, all measurements on the GE-Lunar reference curves for participants younger than 20 yr increase monotonically with age. In the adult population, most of the curves are constant at younger

  8. Design for measurement system of Doppler broadening profiles with the coincidence technique using a NaI detector in colinear geometry with the Ge detector

    International Nuclear Information System (INIS)

    Mori, Kazuteru; Uedono, Akira; Tanigawa, Shoichiro; Nakai, Katsuhiko

    1998-01-01

    The measurement system for Doppler broadening profiles with the coincidence technique using a NaI detector in colinear geometry with a Ge detector was developed. The principle of measurement system with the coincidence technique between the NaI detector and the Ge detector was described. Application of the system for the detection of vacancy-type defects introduced by electron irradiation in Czochralski-(Cz) grown Si was shown. Detail in the difference between the Doppler broadening profiles for Cz-Si and Si grown by the floating-zone method was also obtained. (author)

  9. Design for measurement system of Doppler broadening profiles with the coincidence technique using a NaI detector in colinear geometry with the Ge detector

    Energy Technology Data Exchange (ETDEWEB)

    Mori, Kazuteru; Uedono, Akira; Tanigawa, Shoichiro [Tsukuba Univ., Ibaraki (Japan). Inst. of Materials Science; Nakai, Katsuhiko

    1998-08-01

    The measurement system for Doppler broadening profiles with the coincidence technique using a NaI detector in colinear geometry with a Ge detector was developed. The principle of measurement system with the coincidence technique between the NaI detector and the Ge detector was described. Application of the system for the detection of vacancy-type defects introduced by electron irradiation in Czochralski-(Cz) grown Si was shown. Detail in the difference between the Doppler broadening profiles for Cz-Si and Si grown by the floating-zone method was also obtained. (author)

  10. Cluster self-organization of germanate systems: suprapolyhedral precursor clusters and self-assembly of K2Nd4Ge4O13(OH)4, K2YbGe4O10(OH), K2Sc2Ge2O7(OH)2, and KScGe2O6(PYR)

    International Nuclear Information System (INIS)

    Ilyushin, G.D.; Dem'yanets, L.N.

    2008-01-01

    One performed the computerized (the TOPOS 4.0 software package) geometric and topological analyses of all known types of K, TR-germanates (TR = La-Lu, Y, Sc, In). The skeleton structure are shown as three-dimensional 3D, K, TR, Ge-patterns (graphs) with remote oxygen atoms. TR 4 3 3 4 3 3 + T 4 3 4 3, K 2 YbGe 4 O 14 (OH) pattern, TR 6 6 3 6 + T1 6 8 6 + T2 3 6 8, K 2 Sc 2 Ge 2 O 7 (OH) 2 , TR 6 4 6 4 + T 6 4 6 and KScGe 2 O 6 - TR 6 6 3 6 3 4 + T1 6 3 6 + T2 6 4 3 patterns served as crystal-forming 2D TR,Ge-patterns for K 2 Nd 4 Ge 4 O 13 (OH) 4 . One performed the 3D-simulation of the mechanism of self-arrangement of the crystalline structures: cluster-precursor - parent chain - microlayer - microskeleton (super-precursor). Within K 2 Nd 4 Ge 4 O 13 (OH) 4 , K 2 Sc 2 Ge 2 O 7 (OH) 2 and KScGe 2 O 6 one identified the invariant type of the cyclic hexapolyhedral cluster-precursor consisting of TR-octahedrons linked by diorthogroups stabilized by K atoms. For K 2 Nd 4 Ge 4 O 13 (OH) 4 one determined the type of the cyclic tetrapolyhedral cluster-precursor consisting of TR-octavertices linked by tetrahedrons. The cluster CN within the layer just for KScGe 2 O 6 water-free germanate (the PYR pyroxene analog) is equal to 6 (the maximum possible value), while in the rest OH-containing germanates it constitutes 4. One studied the formation mechanism of Ge-radicals in the form of Ge 2 O 7 and Ge 4 O 13 groupings, GeO 3 chain and the tubular structure consisting of Ge 8 O 20 fixed cyclic groupings [ru

  11. Medical ADP Systems: Automated Medical Records Hold Promise to Improve Patient Care

    Science.gov (United States)

    1991-01-01

    automated medical records. The report discusses the potential benefits that automation could make to the quality of patient care and the factors that impede...information systems, but no organization has fully automated one of the most critical types of information, patient medical records. The patient medical record...its review of automated medical records. GAO’s objectives in this study were to identify the (1) benefits of automating patient records and (2) factors

  12. Intelligent systems in technical and medical diagnostics

    CERN Document Server

    Korbicz, Jozef

    2013-01-01

    For many years technical and medical diagnostics has been the area of intensive scientific research. It covers well-established topics as well as emerging developments in control engineering, artificial intelligence, applied mathematics, pattern recognition and statistics. At the same time, a growing number of applications of different fault diagnosis methods, especially in electrical, mechanical, chemical and medical engineering, is being observed. This monograph contains a collection of 44 carefully selected papers contributed by experts in technical and medical diagnostics, and constitutes

  13. Commissioning and operational results of helium refrigeration system at JLab for the 12GeV upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Knudsen, Peter N. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Ganni, Venkatarao [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Dixon, Kelly D. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Norton, Robert O. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Creel, Jonathan D. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)

    2015-12-01

    The new 4.5 K refrigerator system at the Jefferson Lab (JLab) Central Helium Liquefier (CHL-2) for the 12 GeV upgrade was commissioned in late spring of 2013, following the commissioning of the new compressor system, and has been supporting 12 GeV LINAC commissioning since that time. Six design modes were tested during commissioning, consisting of a maximum capacity, nominal capacity, maximum liquefaction, maximum refrigeration, maximum fill and a stand-by/reduced load condition. The maximum capacity was designed to support a 238 g/s, 30 K and 1.16 bar cold compressor return flow, a 15 g/s, 4.5 K liquefaction load and a 12.6 kW, 35-55 K shield load. The other modes were selected to ensure proper component sizing and selection to allow the cold box to operate over a wide range of conditions and capacities. The cold box system is comprised of two physically independent cold boxes with interconnecting transfer-lines. The outside (upper) 300-60 K vertical cold box has no turbines and incorporates a liquid nitrogen pre-cooler and 80-K beds. The inside (lower) 60-4.5 K horizontal cold box houses seven turbines that are configured in four expansion stages including one Joule-Thompson expander and a 20-K bed. The helium compression system has five compressors to support three pressure levels in the cold box. This paper will summarize the analysis of the test data obtained over the wide range of operating conditions and capacities which were tested.

  14. Medical Terminology of the Circulatory System. Medical Records. Instructional Unit for the Medical Transcriber.

    Science.gov (United States)

    Gosman, Minna L.

    Developed as a result of an analysis of the task of transcribing as practiced in a health facility, this study guide was designed to teach the knowledge and skills required of a medical transcriber. The medical record department was identified as a major occupational area, and a task inventory for medical records was developed and used as a basis…

  15. Medical Terminology of the Respiratory System. Medical Records. Instructional Unit for the Medical Transcriptionist.

    Science.gov (United States)

    Gosman, Minna L.

    Following an analysis of the task of transcribing as practiced in a health facility, this study guide was designed to teach the knowledge and skills required of a medical transcriber. The medical record department was identified as a major occupational area, and a task inventory for medical records was developed and used as a basis for…

  16. Medical Terminology of the Musculoskeletal System. Medical Records. Instructional Unit for the Medical Transcriber.

    Science.gov (United States)

    Gosman, Minna L.

    Following an analysis of the task of transcribing as practiced in a health facility, this study guide was developed to teach the knowledge and skills required of a medical transcriber. The medical record department was identified as a major occupational area, and a task inventory for medical records was developed and used as a basis for a…

  17. Implementation of an Electronic Medical Records System

    National Research Council Canada - National Science Library

    Fletcher, Chadwick B

    2008-01-01

    .... Substantial benefits are realized through routine use of electronic medical records include improved quality, safety, and efficiency, along with the increased ability to conduct education and research...

  18. Ge/SiGe superlattices for nanostructured thermoelectric modules

    International Nuclear Information System (INIS)

    Chrastina, D.; Cecchi, S.; Hague, J.P.; Frigerio, J.; Samarelli, A.; Ferre–Llin, L.; Paul, D.J.; Müller, E.; Etzelstorfer, T.; Stangl, J.; Isella, G.

    2013-01-01

    Thermoelectrics are presently used in a number of applications for both turning heat into electricity and also for using electricity to produce cooling. Mature Si/SiGe and Ge/SiGe heteroepitaxial growth technology would allow highly efficient thermoelectric materials to be engineered, which would be compatible and integrable with complementary metal oxide silicon micropower circuits used in autonomous systems. A high thermoelectric figure of merit requires that electrical conductivity be maintained while thermal conductivity is reduced; thermoelectric figures of merit can be improved with respect to bulk thermoelectric materials by fabricating low-dimensional structures which enhance the density of states near the Fermi level and through phonon scattering at heterointerfaces. We have grown and characterized Ge-rich Ge/SiGe/Si superlattices for nanofabricated thermoelectric generators. Low-energy plasma-enhanced chemical vapor deposition has been used to obtain nanoscale-heterostructured material which is several microns thick. Crystal quality and strain control have been investigated by means of high resolution X-ray diffraction. High-resolution transmission electron microscopy images confirm the material and interface quality. Electrical conductivity has been characterized by the mobility spectrum technique. - Highlights: ► High-quality Ge/SiGe multiple quantum wells for thermoelectric applications ► Mobility spectra of systems featuring a large number of parallel conduction channels ► Competitive thermoelectric properties measured in single devices

  19. Study of K* meson production in PHENIX for d + Au and Cu + Cu systems at √sNN = 200 GeV at RHIC

    International Nuclear Information System (INIS)

    Sett, P.; Mishra, D.K.; Shukla, P.; Choudhury, R.K.

    2011-01-01

    Quantum Chromodynamics (QCD) predicts a phase transition from nuclear matter to quark gluon plasma (QGP) at energy density higher than >1 GeV/fm 3 achievable in high energy heavy ion collisions. Measurements of various mesons and baryons provide the information about the interaction dynamics in heavy ion collision. Lighter systems such as p+p are used as baseline for production mechanism and d+Au for the cold nuclear matter effects such as shadowing and Cronin effect. The K* transverse momentum spectra for d+Au system for different centralities has been measured in the pT range of 0.9 GeV/c within the uncertainties

  20. 21 CFR 892.5300 - Medical neutron radiation therapy system.

    Science.gov (United States)

    2010-04-01

    ... therapy system. (a) Identification. A medical neutron radiation therapy system is a device intended to... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical neutron radiation therapy system. 892.5300... analysis and display equipment, patient and equipment support, treatment planning computer programs...

  1. An anti-Compton suppression Ge-telescope detection system for quality control of nuclear waste packages

    International Nuclear Information System (INIS)

    Agosteo, S.; Para, A. Foglio; Chabalier, B.; Huot, N.; Graf, U.; Ravazzani, A.; Schillebeeckx, P.; Kekki, T.; Tanner, V.; Tiitta, A.

    2001-01-01

    An anti-Compton suppression system is studied for the quality control of radioactive waste packages by nondestructive assay. The main objective is the reduction of the detection limit of actinides in the packages. The optimization of a final device is based on Monte Carlo simulations (MCNP and FLUKA) validated by experiments using a prototype consisting of a Ge-telescope detector surrounded by a NaI detector. The validation reveals that most of the discrepancies between experimental and simulated data are due to an incomplete description of the experimental conditions. After fine-tuning of the input file the uncertainties on the simulated full-energy peak efficiency are reduced to less than 5%. Also the total detector response for mono-energetic photons and real waste, including the photon interactions within the drum, can be simulated satisfactorily

  2. Eiperimental and thermodynamic study od curve of retrograde solidus in InP-Ge quasi-binary system

    International Nuclear Information System (INIS)

    Glazov, V.M.; Pavlova, L.M.; Perederij, L.I.

    1983-01-01

    Germanium solubility in indium phosphide at different temperatures is experimentally investigated, and it is shown that the solidus curve in the portion adjoining InP is of a retrograde character. The method of radioactive tracers has been used to determine the coefficient of germanium distribution between the liquid and solid phases at a melting point of indium phosphide. Concentration dependence of the number of electrons at indium phosphide doping with germanium is investigated, and violation of the ionization equality is shown that is explained by an amphoteric character of o.ermanium behaviour in the InP base solid solution resulting in a self-compensation effect. The retrograde solidus curve in the InP-Ge system is calculated thermodynamically with the use of model representations on the composition of solid and liquid solutions. The ionization degree of doping impurity and self-compensation effect are taken account in calculation. Good agreement of the calculated and experimental data is observed

  3. Lattice parameters values and phase diagram for the Cu{sub 2}Zn{sub 1-z}Fe{sub z}GeSe{sub 4} alloy system

    Energy Technology Data Exchange (ETDEWEB)

    Caldera, D. [Centro de Estudios de Semiconductores, Departamento de Fisica, Facultad de Ciencias, Universidad de Los Andes, Merida 5101 (Venezuela); Quintero, M. [Centro de Estudios de Semiconductores, Departamento de Fisica, Facultad de Ciencias, Universidad de Los Andes, Merida 5101 (Venezuela)], E-mail: mquinter@ula.ve; Morocoima, M.; Quintero, E.; Grima, P.; Marchan, N.; Moreno, E.; Bocaranda, P. [Centro de Estudios de Semiconductores, Departamento de Fisica, Facultad de Ciencias, Universidad de Los Andes, Merida 5101 (Venezuela); Delgado, G.E. [Laboratorio de Cristalografia, Departamento de Quimica, Facultad de Ciencias, Universidad de Los Andes, Merida 5101 (Venezuela); Mora, A.E.; Briceno, J.M.; Fernandez, J.L. [Laboratorio de Analisis Quimico y Estructura de Materiales, Departamento de Fisica, Universidad de Los Andes, Merida 5101 (Venezuela)

    2008-06-12

    X-ray powder diffraction and differential thermal analysis (DTA) measurements were made on polycrystalline samples of the Cu{sub 2}Zn{sub 1-z}Fe{sub z}GeSe{sub 4} alloy system. The diffraction patterns were used to show the equilibrium conditions and to estimate crystalline parameter values. It was found that, at room temperature, a single phase solid solution with the tetragonal stannite {alpha} structure (I4-bar2m) occurs across the whole composition range. The DTA thermograms were used to construct the phase diagram of the Cu{sub 2}Zn{sub 1-z}Fe{sub z}GeSe{sub 4} alloy system. It was confirmed that the Cu{sub 2}ZnGeSe{sub 4} compound melts incongruently. It was observed that undercooling effects occur for samples with z > 0.9.

  4. Medication Safety Systems and the Important Role of Pharmacists.

    Science.gov (United States)

    Mansur, Jeannell M

    2016-03-01

    Preventable medication-related adverse events continue to occur in the healthcare setting. While the Institute of Medicine's To Err is Human, published in 2000, highlighted the prevalence of medical and medication-related errors in patient morbidity and mortality, there has not been significant documented progress in addressing system contributors to medication errors. The lack of progress may be related to the myriad of pharmaceutical options now available and the nuances of optimizing drug therapy to achieve desired outcomes and prevent undesirable outcomes. However, on a broader scale, there may be opportunities to focus on the design and performance of the many processes that are part of the medication system. Errors may occur in the storage, prescribing, transcription, preparation and dispensing, or administration and monitoring of medications. Each of these nodes of the medication system, with its many components, is prone to failure, resulting in harm to patients. The pharmacist is uniquely trained to be able to impact medication safety at the individual patient level through medication management skills that are part of the clinical pharmacist's role, but also to analyze the performance of medication processes and to lead redesign efforts to mitigate drug-related outcomes that may cause harm. One population that can benefit from a focus on medication safety through clinical pharmacy services and medication safety programs is the elderly, who are at risk for adverse drug events due to their many co-morbidities and the number of medications often used. This article describes the medication safety systems and provides a blueprint for creating a foundation for medication safety programs within healthcare organizations. The specific role of pharmacists and clinical pharmacy services in medication safety is also discussed here and in other articles in this Theme Issue.

  5. Adaptive Systems Engineering: A Medical Paradigm for Practicing Systems Engineering

    Energy Technology Data Exchange (ETDEWEB)

    R. Douglas Hamelin; Ron D. Klingler; Christopher Dieckmann

    2011-06-01

    From its inception in the defense and aerospace industries, SE has applied holistic, interdisciplinary tools and work-process to improve the design and management of 'large, complex engineering projects.' The traditional scope of engineering in general embraces the design, development, production, and operation of physical systems, and SE, as originally conceived, falls within that scope. While this 'traditional' view has expanded over the years to embrace wider, more holistic applications, much of the literature and training currently available is still directed almost entirely at addressing the large, complex, NASA and defense-sized systems wherein the 'ideal' practice of SE provides the cradle-to-grave foundation for system development and deployment. Under such scenarios, systems engineers are viewed as an integral part of the system and project life-cycle from conception to decommissioning. In far less 'ideal' applications, SE principles are equally applicable to a growing number of complex systems and projects that need to be 'rescued' from overwhelming challenges that threaten imminent failure. The medical profession provides a unique analogy for this latter concept and offers a useful paradigm for tailoring our 'practice' of SE to address the unexpected dynamics of applying SE in the real world. In short, we can be much more effective as systems engineers as we change some of the paradigms under which we teach and 'practice' SE.

  6. CT vs 68Ge attenuation correction in a combined PET/CT system: evaluation of the effect of lowering the CT tube current

    International Nuclear Information System (INIS)

    Kamel, Ehab; Hany, Thomas F.; Burger, Cyrill; Treyer, Valerie; Schulthess von, Gustav K.; Buck, Alfred; Lonn, Albert H.R.

    2002-01-01

    With the introduction of combined positron emission tomography/computed tomography (PET/CT) systems, several questions have to be answered. In this work we addressed two of these questions: (a) to what value can the CT tube current be reduced while still yielding adequate maps for the attenuation correction of PET emission scans and (b) how do quantified uptake values in tumours derived from CT and germanium-68 attenuation correction compare. In 26 tumour patients, multidetector CT scans were acquired with 10, 40, 80 and 120 mA (CT 10 , CT 40 , CT 80 and CT 120 ) and used for the attenuation correction of a single FDG PET emission scan, yielding four PET scans designated PET CT10 -PET CT120 . In 60 tumorous lesions, FDG uptake and lesion size were quantified on PET CT10 -PET CT120 . In another group of 18 patients, one CT scan acquired with 80 mA and a standard transmission scan acquired using 68 Ge sources were employed for the attenuation correction of the FDG emission scan (PET CT80 , PET 68Ge ). Uptake values and lesion size in 26 lesions were compared on PET CT80 and PET 68Ge . In the first group of patients, analysis of variance revealed no significant effect of CT current on tumour FDG uptake or lesion size. In the second group, tumour FDG uptake was slightly higher using CT compared with 68 Ge attenuation correction, especially in lesions with high FDG uptake. Lesion size was similar on PET CT80 and PET 68Ge . In conclusion, low CT currents yield adequate maps for the attenuation correction of PET emission scans. Although the discrepancy between CT- and 68 Ge-derived uptake values is probably not relevant in most cases, it should be kept in mind if standardised uptake values derived from CT and 68 Ge attenuation correction are compared. (orig.)

  7. The current medical education system in the world.

    Science.gov (United States)

    Nara, Nobuo; Suzuki, Toshiya; Tohda, Shuji

    2011-07-04

    To contribute to the innovation of the medical education system in Japan, we visited 35 medical schools and 5 institutes in 12 countries of North America, Europe, Australia and Asia in 2008-2010 and observed the education system. We met the deans, medical education committee and administration affairs and discussed about the desirable education system. We also observed the facilities of medical schools.Medical education system shows marked diversity in the world. There are three types of education course; non-graduate-entry program(non-GEP), graduate-entry program(GEP) and mixed program of non-GEP and GEP. Even in the same country, several types of medical schools coexist. Although the education methods are also various among medical schools, most of the medical schools have introduced tutorial system based on PBL or TBL and simulation-based learning to create excellent medical physicians. The medical education system is variable among countries depending on the social environment. Although the change in education program may not be necessary in Japan, we have to innovate education methods; clinical training by clinical clerkship must be made more developed to foster the training of the excellent clinical physicians, and tutorial education by PBL or TBL and simulation-based learning should be introduced more actively.

  8. Medical Operations Decision Support System, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Determining the probability of specific medical events on a given space mission is difficult. Yet, it is important to have reasonable estimates of these...

  9. GE Healthcare | College of Engineering & Applied Science

    Science.gov (United States)

    Olympiad Girls Who Code Club FIRST Tech Challenge NSF I-Corps Site of Southeastern Wisconsin UW-Milwaukee ; Talent GE Healthcare is the founding partner of the Center for Advanced Embedded Systems (CAES), formerly GE Healthcare's needs for talent. Business Corporate Partners ANSYS Institute GE Healthcare Catalyst

  10. Development of an integrated medical supply information system

    Science.gov (United States)

    Xu, Eric; Wermus, Marek; Blythe Bauman, Deborah

    2011-08-01

    The integrated medical supply inventory control system introduced in this study is a hybrid system that is shaped by the nature of medical supply, usage and storage capacity limitations of health care facilities. The system links demand, service provided at the clinic, health care service provider's information, inventory storage data and decision support tools into an integrated information system. ABC analysis method, economic order quantity model, two-bin method and safety stock concept are applied as decision support models to tackle inventory management issues at health care facilities. In the decision support module, each medical item and storage location has been scrutinised to determine the best-fit inventory control policy. The pilot case study demonstrates that the integrated medical supply information system holds several advantages for inventory managers, since it entails benefits of deploying enterprise information systems to manage medical supply and better patient services.

  11. Several new phases in RE-Mg-Ge systems (RE = rare earth metal) - syntheses, structures, and chemical bonding

    International Nuclear Information System (INIS)

    Suen, Nian-Tzu; Bobev, Svilen

    2012-01-01

    Reported are the synthesis and structural characterization of Ce_5Mg_8Ge_8 (its own structure type), CeMg_2_-_xGe_2_+_x (BaAl_4-type structure), RE_4Mg_7Ge_6 (RE = Ce-Nd, Sm; La_4Mg_7Ge_6-type structure), and RE_4Mg_5Ge_6 (RE = Ce, Pr; Tm_4Zn_5Ge_6-type structure). The structures of these compounds have been established by single-crystal and powder X-ray diffraction. These compounds are closely related to each other not only in their chemical compositions but also in their structures. A common structural feature of all are MgGe_4 tetrahedra, which are connected by corner- and/or edge-sharing into complex polyanionic frameworks with the rare-earth metal atoms filling the ''empty'' space. The structures are compared to known types of structures, and we have investigated the chemical bonding in Ce_5Mg_8Ge_8 with electronic structure calculations, which were carried out by the tight-bonding linear muffin-tin orbital (TB-LMTO) method. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  12. Nuclear magnetic resonance investigation of the heavy fermion system Ce2CoAl7Ge4

    Science.gov (United States)

    Dioguardi, A. P.; Guzman, P.; Rosa, P. F. S.; Ghimire, N. J.; Eley, S.; Brown, S. E.; Thompson, J. D.; Bauer, E. D.; Ronning, F.

    2017-12-01

    We present nuclear magnetic resonance (NMR) and nuclear quadrupole resonance (NQR) measurements performed on single crystalline Ce2CoAl7Ge4 , a member of a recently discovered family of heavy fermion materials Ce2M Al7Ge4 (M =Co , Ir, Ni, or Pd). Previous measurements indicated a strong Kondo interaction as well as magnetic order below TM=1.8 K . Our NMR spectral measurements show that the Knight shift K is proportional to the bulk magnetic susceptibility χ at high temperatures. A clear Knight shift anomaly (K ¬∝χ ) is observed at coherence temperatures T*˜17.5 K for H0∥c ̂ and 10 K for H0∥a ̂ at the 59Co site, and T*˜12.5 K at the 27Al(3) site for H0∥a ̂ characteristic of the heavy fermion nature of this compound. At high temperatures, the 59Co NMR spin-lattice relaxation rate T1-1 is dominated by spin fluctuations of the 4 f local moments with a weak metallic background. The spin fluctuations probed by 59Co NMR are anisotropic and larger in the basal plane than in the c direction. Furthermore, we find (T1T K ) -1∝T-1 /2 at the 59Co site as expected for a Kondo system for T >T* and T >TK . 59Co NQR T1-1 measurements at low temperatures indicate slowing down of spin fluctuations above the magnetic ordering temperature TM˜1.8 K . A weak ferromagnetic character of fluctuations around q =0 is evidenced by an increase of χ T versus T above the magnetic ordering temperature. We also find good agreement between the observed and calculated electric field gradients at all observed sites.

  13. System Dynamics in Medical Education: A Tool for Life

    Science.gov (United States)

    Rubin, David M.; Richards, Christopher L.; Keene, Penelope A. C.; Paiker, Janice E.; Gray, A. Rosemary T.; Herron, Robyn F. R.; Russell, Megan J.; Wigdorowitz, Brian

    2012-01-01

    A course in system dynamics has been included in the first year of our university's six-year medical curriculum. System Dynamics is a discipline that facilitates the modelling, simulation and analysis of a wide range of problems in terms of two fundamental concepts viz. rates and levels. Many topics encountered in the medical school curriculum,…

  14. System for digitalization of medical images based on DICOM standard

    Directory of Open Access Journals (Sweden)

    Čabarkapa Slobodan

    2009-01-01

    Full Text Available According to DICOM standard, which defines both medical image information and user information, a new system for digitalizing medical images is involved as a part of the main system for archiving and retrieving medical databases. The basic characteristics of this system are described in this paper. Furthermore, the analysis of some important DICOM header's tags which are used in this system, are presented, too. Having chosen the appropriate tags in order to preserve important information, the efficient system has been created. .

  15. Using an electronic prescribing system to ensure accurate medication lists in a large multidisciplinary medical group.

    Science.gov (United States)

    Stock, Ron; Scott, Jim; Gurtel, Sharon

    2009-05-01

    Although medication safety has largely focused on reducing medication errors in hospitals, the scope of adverse drug events in the outpatient setting is immense. A fundamental problem occurs when a clinician lacks immediate access to an accurate list of the medications that a patient is taking. Since 2001, PeaceHealth Medical Group (PHMG), a multispecialty physician group, has been using an electronic prescribing system that includes medication-interaction warnings and allergy checks. Yet, most practitioners recognized the remaining potential for error, especially because there was no assurance regarding the accuracy of information on the electronic medical record (EMR)-generated medication list. PeaceHealth developed and implemented a standardized approach to (1) review and reconcile the medication list for every patient at each office visit and (2) report on the results obtained within the PHMG clinics. In 2005, PeaceHealth established the ambulatory medication reconciliation project to develop a reliable, efficient process for maintaining accurate patient medication lists. Each of PeaceHealth's five regions created a medication reconciliation task force to redesign its clinical practice, incorporating the systemwide aims and agreed-on key process components for every ambulatory visit. Implementation of the medication reconciliation process at the PHMG clinics resulted in a substantial increase in the number of accurate medication lists, with fewer discrepancies between what the patient is actually taking and what is recorded in the EMR. The PeaceHealth focus on patient safety, and particularly the reduction of medication errors, has involved a standardized approach for reviewing and reconciling medication lists for every patient visiting a physician office. The standardized processes can be replicated at other ambulatory clinics-whether or not electronic tools are available.

  16. Development of a medical staff recruitment system for teaching ...

    African Journals Online (AJOL)

    Development of a medical staff recruitment system for teaching hospitals in Nigeria. ... Nigeria, were visited and relevant information was collated through personal ... The design and development of the system employs 3-tier web architecture.

  17. Development of total medical material distribution management system.

    Science.gov (United States)

    Uto, Y; Kumamoto, I

    1994-07-01

    Since September 1992, attempts have been made at Kagoshima University Hospital to develop the Medical Material Distribution Management System which helps to realize optimal hospital management as a subsystem of the Total Hospital Information System of Kagoshima University (THINK). As this system has been established, it has become possible for us to have an accurate grasp of the flow and stock of medical materials at our hospital. Furthermore, since September 1993, the Medical Material Distribution Management System has been improved and the Total Medical Material Distribution Management System has been smoothly introduced into the site of clinical practice. This system enables automatic demands for fees for treatment with specific instruments and materials covered by health insurance. It was difficult to predict the effect of this system, because no similar system had been developed in Japan. However, more satisfactory results than expected have been obtained since its introduction.

  18. A study of KK-bar system produced in the reaction Π-p#-> #KK-barn at 63 GeV

    International Nuclear Information System (INIS)

    Palka, H.

    1983-01-01

    An analysis of KK-bar system produced in the reaction Π - p#-> #KK-barn at 63 GeV and measured by ACCMOR (Amsterdam-CERN-Cracow-Munich-Oxford-Rutherford) collaboration at the CERN SPS accelelator is presented. (author)

  19. Implementation of medical monitor system based on networks

    Science.gov (United States)

    Yu, Hui; Cao, Yuzhen; Zhang, Lixin; Ding, Mingshi

    2006-11-01

    In this paper, the development trend of medical monitor system is analyzed and portable trend and network function become more and more popular among all kinds of medical monitor devices. The architecture of medical network monitor system solution is provided and design and implementation details of medical monitor terminal, monitor center software, distributed medical database and two kind of medical information terminal are especially discussed. Rabbit3000 system is used in medical monitor terminal to implement security administration of data transfer on network, human-machine interface, power management and DSP interface while DSP chip TMS5402 is used in signal analysis and data compression. Distributed medical database is designed for hospital center according to DICOM information model and HL7 standard. Pocket medical information terminal based on ARM9 embedded platform is also developed to interactive with center database on networks. Two kernels based on WINCE are customized and corresponding terminal software are developed for nurse's routine care and doctor's auxiliary diagnosis. Now invention patent of the monitor terminal is approved and manufacture and clinic test plans are scheduled. Applications for invention patent are also arranged for two medical information terminals.

  20. SCANPLAN planning system for medical accelerators

    International Nuclear Information System (INIS)

    Ovsyannikov, D.A.; Sergeev, S.L.; Stuchenkov, A.B.; Vorogushin, M.F.; Tikhomirov, A.S.; Shishov, V.A.

    2001-01-01

    The SCANPLAN automatic system for planning and documentation of every treatment of the photon radiotherapy is described. The system is oriented at the operating systems Windows 98, 2000 and is developed with using the Visual Studio 6.0 technology. This system consists of the following components: planning unit, module for preparation of anatomical information, data base and patient catalogs [ru

  1. Establishment of a Quantitative Medical Technology Evaluation System and Indicators within Medical Institutions

    Directory of Open Access Journals (Sweden)

    Suo-Wei Wu

    2018-01-01

    Conclusions: As the two-round questionnaire survey of experts and statistical analysis were performed and credibility of the results was verified through consistency evaluation test, the study established a quantitative medical technology evaluation system model and assessment indicators within medical institutions based on the Delphi method and analytical hierarchy process. Moreover, further verifications, adjustments, and optimizations of the system and indicators will be performed in follow-up studies.

  2. MedRapid--medical community & business intelligence system.

    Science.gov (United States)

    Finkeissen, E; Fuchs, H; Jakob, T; Wetter, T

    2002-01-01

    currently, it takes at least 6 months for researchers to communicate their results. This delay is caused (a) by partial lacks of machine support for both representation as well as communication and (b) by media breaks during the communication process. To make an integrated communication between researchers and practitioners possible, a general structure for medical content representation has been set up. The procedure for data entry and quality management has been generalized and implemented in a web-based authoring system. The MedRapid-system supports the medical experts in entering their knowledge into a database. Here, the level of detail is still below that of current medical guidelines representation. However, the symmetric structure for an area-wide medical knowledge representation is highly retrievable and thus can quickly be communicated into daily routine for the improvement of the treatment quality. In addition, other sources like journal articles and medical guidelines can be references within the MedRapid-system and thus be communicated into daily routine. The fundamental system for the representation of medical reference knowledge (from reference works/books) itself is not sufficient for the friction-less communication amongst medical staff. Rather, the process of (a) representing medical knowledge, (b) refereeing the represented knowledge, (c) communicating the represented knowledge, and (d) retrieving the represented knowledge has to be unified. MedRapid will soon support the whole process on one server system.

  3. Asan medical information system for healthcare quality improvement.

    Science.gov (United States)

    Ryu, Hyeon Jeong; Kim, Woo Sung; Lee, Jae Ho; Min, Sung Woo; Kim, Sun Ja; Lee, Yong Su; Lee, Young Ha; Nam, Sang Woo; Eo, Gi Seung; Seo, Sook Gyoung; Nam, Mi Hyun

    2010-09-01

    This purpose of this paper is to introduce the status of the Asan Medical Center (AMC) medical information system with respect to healthcare quality improvement. Asan Medical Information System (AMIS) is projected to become a completely electronic and digital information hospital. AMIS has played a role in improving the health care quality based on the following measures: safety, effectiveness, patient-centeredness, timeliness, efficiency, privacy, and security. AMIS CONSISTED OF SEVERAL DISTINCTIVE SYSTEMS: order communication system, electronic medical record, picture archiving communication system, clinical research information system, data warehouse, enterprise resource planning, IT service management system, and disaster recovery system. The most distinctive features of AMIS were the high alert-medication recognition & management system, the integrated and severity stratified alert system, the integrated patient monitoring system, the perioperative diabetic care monitoring and support system, and the clinical indicator management system. AMIS provides IT services for AMC, 7 affiliated hospitals and over 5,000 partners clinics, and was developed to improve healthcare services. The current challenge of AMIS is standard and interoperability. A global health IT strategy is needed to get through the current challenges and to provide new services as needed.

  4. MSU 1.6 GeV/c beam analysis system

    International Nuclear Information System (INIS)

    Nolen, J.A. Jr.

    1981-01-01

    This report describes the design of the beam analysis system which is to prepare the beam for the large high-resolution spectrograph to be used with the superconducting heavy ion cyclotrons at MSU. The system has a momentum resolving power of over 20,000 with a 1 mm object slit and is of a very flexible, modular design which is readily adaptable to other applications

  5. Influence of nonmagnetic disorder on specific heat and electrical resistivity in Kondo lattice system CePd{sub 1−x}Ge{sub x}In

    Energy Technology Data Exchange (ETDEWEB)

    Gnida, D., E-mail: d.gnida@int.pan.wroc.pl [Institute of Low Temperature and Structure Research, Polish Academy of Sciences, 50-950 Wrocław (Poland); Dominyuk, N.; Zaremba, V. [Inorganic Chemistry Department, Ivan Franko Lviv National University, Kyryla and Mephodiya Str. 6, 79005 Lviv (Ukraine); Kaczorowski, D. [Institute of Low Temperature and Structure Research, Polish Academy of Sciences, 50-950 Wrocław (Poland)

    2015-02-15

    Highlights: • Interplay of Kondo and RKKY interactions in the presence of nonmagnetic disorder. • Suppression of the coherent Kondo state by nonmagnetic impurities. • Observation of quantum interference phenomena in Ce-based Kondo system. • Coexistence of incoherent Kondo effect and Altshuler-Aronov quantum correction. - Abstract: The alloy system CePd{sub 1−x}Ge{sub x}In with 0.1⩽x⩽0.4 was investigated by means of heat capacity and electrical resistivity measurements. Its low-temperature behavior has been found to be governed by the interplay of Kondo effect and Ruderman-Kittel-Kasuya-Yosida (RKKY) interactions in the presence of atomic disorder in nonmagnetic atoms sublattice. The coherent Kondo state, observed for CePdIn, gradually vanishes with increasing the Ge-content. The incoherent Kondo state, which characterizes Ge-rich alloys, appears very sensitive to applied magnetic field. The observed systematic changes in the temperature- and field-dependent electrical transport in CePd{sub 1−x}Ge{sub x}In manifest the important role of quantum correction due to electron-electron interactions in weakly localized regime.

  6. Establishment of a Quantitative Medical Technology Evaluation System and Indicators within Medical Institutions.

    Science.gov (United States)

    Wu, Suo-Wei; Chen, Tong; Pan, Qi; Wei, Liang-Yu; Wang, Qin; Li, Chao; Song, Jing-Chen; Luo, Ji

    2018-06-05

    The development and application of medical technologies reflect the medical quality and clinical capacity of a hospital. It is also an effective approach in upgrading medical service and core competitiveness among medical institutions. This study aimed to build a quantitative medical technology evaluation system through questionnaire survey within medical institutions to perform an assessment to medical technologies more objectively and accurately, and promote the management of medical quality technologies and ensure the medical safety of various operations among the hospitals. A two-leveled quantitative medical technology evaluation system was built through a two-round questionnaire survey of chosen experts. The Delphi method was applied in identifying the structure of evaluation system and indicators. The judgment of the experts on the indicators was adopted in building the matrix so that the weight coefficient and maximum eigenvalue (λ max), consistency index (CI), and random consistency ratio (CR) could be obtained and collected. The results were verified through consistency tests, and the index weight coefficient of each indicator was conducted and calculated through analytical hierarchy process. Twenty-six experts of different medical fields were involved in the questionnaire survey, 25 of whom successfully responded to the two-round research. Altogether, 4 primary indicators (safety, effectiveness, innovativeness, and benefits), as well as 13 secondary indicators, were included in the evaluation system. The matrix is built to conduct the λ max, CI, and CR of each expert in the survey, and the index weight coefficients of primary indicators were 0.33, 0.28, 0.27, and 0.12, respectively, and the index weight coefficients of secondary indicators were conducted and calculated accordingly. As the two-round questionnaire survey of experts and statistical analysis were performed and credibility of the results was verified through consistency evaluation test, the

  7. Ecological theories of systems and contextual change in medical education.

    Science.gov (United States)

    Ellaway, Rachel H; Bates, Joanna; Teunissen, Pim W

    2017-12-01

    Contemporary medical practice is subject to many kinds of change, to which both individuals and systems have to respond and adapt. Many medical education programmes have their learners rotating through different training contexts, which means that they too must learn to adapt to contextual change. Contextual change presents many challenges to medical education scholars and practitioners, not least because of a somewhat fractured and contested theoretical basis for responding to these challenges. There is a need for robust concepts to articulate and connect the various debates on contextual change in medical education. Ecological theories of systems encompass a range of concepts of how and why systems change and how and why they respond to change. The use of these concepts has the potential to help medical education scholars explore the nature of change and understand the role it plays in affording as well as limiting teaching and learning. This paper, aimed at health professional education scholars and policy makers, explores a number of key concepts from ecological theories of systems to present a comprehensive model of contextual change in medical education to inform theory and practice in all areas of medical education. The paper considers a range of concepts drawn from ecological theories of systems, including biotic and abiotic factors, panarchy, attractors and repellers, basins of attraction, homeostasis, resilience, adaptability, transformability and hysteresis. Each concept is grounded in practical examples from medical education. Ecological theories of systems consider change and response in terms of adaptive cycles functioning at different scales and speeds. This can afford opportunities for systematic consideration of responses to contextual change in medical education, which in turn can inform the design of education programmes, activities, evaluations, assessments and research that accommodates the dynamics and consequences of contextual change.

  8. The role of analytical sciences in medical systems biology

    NARCIS (Netherlands)

    Greef, J. van der; Stroobant, P.; Heijden, R. van der

    2004-01-01

    Medical systems biology has generated widespread interest because of its bold conception and exciting potential, but the field is still in its infancy. Although there has been tremendous progress achieved recently in generating, integrating and analysing data in the medical and pharmaceutical field,

  9. High-Pressure Study of Perovskites and Postperovskites in the (Mg,Fe)GeO 3 System

    Energy Technology Data Exchange (ETDEWEB)

    Stan, Camelia V.; Dutta, Rajkrishna; Cava, Robert J.; Prakapenka, Vitali B.; Duffy, Thomas S. (Princeton); (UC)

    2017-06-22

    The effect of incorporation of Fe2+ on the perovskite (Pbnm) and postperovskite (Cmcm) structures was investigated in the (Mg,Fe)GeO3 system at high pressures and temperatures using laser-heated diamond anvil cell and synchrotron X-ray diffraction. Samples with compositions of Mg# ≥ 48 were shown to transform to the perovskite (~30 GPa and ~1500 K) and postperovskite (>55 GPa, ~1600–1800 K) structures. Compositions with Mg# ≥ 78 formed single-phase perovskite and postperovskite, whereas those with Mg# < 78 showed evidence for partial decomposition. The incorporation of Fe into the perovskite structure causes a decrease in octahedral distortion as well as a modest decrease in bulk modulus (K0) and a modest increase in zero-pressure volume (V0). It also leads to a decrease in the perovskite-to-postperovskite phase transition pressure by ~9.5 GPa over compositions from Mg#78 to Mg#100.

  10. An interpretation of the behavior of EoS/GE models for asymmetric systems

    DEFF Research Database (Denmark)

    Kontogeorgis, Georgios; Panayiotis, Vlamos

    2000-01-01

    or zero pressure or at other conditions (system's pressure, constant volume packing fraction). In a number of publications over the last years, the achievements and the shortcomings of the various EoS/G(E) models have been presented via phase equilibrium calculations. This short communication provides...... an explanation of several literature EoSIGE models, especially those based on zero-reference pressure (PSRK, MHV1, MHV2), in the prediction of phase equilibria for asymmetric systems as well as an interpretation of the LCVM and kappa-MHV1 models which provide an empirical - yet as shown here theoretically...... justified - solution to these problems. (C) 2000 Elsevier Science Ltd. All rights reserved....

  11. Uniaxially stressed Ge:Ga and Ge:Be

    Energy Technology Data Exchange (ETDEWEB)

    Dubon, Jr., Oscar Danilo [Univ. of California, Berkeley, CA (United States)

    1992-12-01

    The application of a large uniaxial stress to p-type Ge single crystals changes the character of both the valence band and the energy levels associated with the acceptors. Changes include the splitting of the fourfold degeneracy of the valence band top and the reduction of the ionization energy of shallow acceptors. In order to study the effect of uniaxial stress on transport properties of photoexcited holes, a variable temperature photo-Hall effect system was built in which stressed Ge:Ga and Ge:Be could be characterized. Results indicate that stress increases the lifetime and Hall mobility of photoexcited holes. These observations may help further the understanding of fundamental physical processes that affect the performance of stressed Ge photoconductors including the capture of holes by shallow acceptors.

  12. Improved control system of the thyristor flicker suppressor for the KEK 12-GeV PS

    International Nuclear Information System (INIS)

    Matsumoto, S.; Baba, H.; Mikawa, K.; Sato, H.; Sueno, T.

    1983-01-01

    Thyristor control system of the 20 MVar flicker suppressor has been improved essentially. The previous feed forward (FF) loop with each single phase reactive current detector of the MR magnet power supply was exchanged to the present by both FF- and NFB-loops. The FF-loops consists of a three phase reactive power detector of the MPS and a forcing pattern generator on the fast but steady line voltage flicker, sag and surge. The NFB-loops control by the slow parts of the flicker and the unbalanced line voltages. These detectors of the reactive power, the voltage flicker and the unbalance have been developed. Sampled voltage flicker data with 12 bit ADC are processed by Z-80A micro computer system and the forcing pattern is generated by the system through 12 bit DAC into the loop. A typical voltage flicker including sag and surge has been reduced within + or - 1.5%, about 1/3 compared to the previous, at 66 kV primary line

  13. Environmental, Health and Safety Assessment: ATS 7H Program (Phase 3R) Test Activities at the GE Power Systems Gas Turbine Manufacturing Facility, Greenville, SC

    Energy Technology Data Exchange (ETDEWEB)

    None

    1998-11-17

    International Technology Corporation (IT) was contracted by General Electric Company (GE) to assist in the preparation of an Environmental, Health and Safety (HI&3) assessment of the implementation of Phase 3R of the Advanced Turbine System (ATS) 7H program at the GE Gas Turbines facility located in Greenville, South Carolina. The assessment was prepared in accordance with GE's contractual agreement with the U.S. Department of Energy (GE/DOE Cooperative Agreement DE-FC21-95MC3 1176) and supports compliance with the requirements of the National Environmental Policy Act of 1970. This report provides a summary of the EH&S review and includes the following: General description of current site operations and EH&S status, Description of proposed ATS 7H-related activities and discussion of the resulting environmental, health, safety and other impacts to the site and surrounding area. Listing of permits and/or licenses required to comply with federal, state and local regulations for proposed 7H-related activities. Assessment of adequacy of current and required permits, licenses, programs and/or plans.

  14. The new innovative medical education system in Ethiopia ...

    African Journals Online (AJOL)

    User

    Background: A New Innovative Medical Education Initiative (NIMEI) had been launched in Ethiopia in February ... development as well as for the overall health system of the country. .... A national survey was conducted in all regions of Ethiopia.

  15. The design and implementation of online medical record system ...

    African Journals Online (AJOL)

    The design and implementation of online medical record system (OMRS) ... PROMOTING ACCESS TO AFRICAN RESEARCH. AFRICAN JOURNALS ONLINE (AJOL) ... International Journal of Natural and Applied Sciences. Journal Home ...

  16. Administrative compensation for medical injuries: lessons from three foreign systems.

    Science.gov (United States)

    Mello, Michelle M; Kachalia, Allen; Studdert, David M

    2011-07-01

    The United States requires patients injured by medical negligence to seek compensation through lawsuits, an approach that has drawbacks related to fairness, cost, and impact on medical care. Several countries, including New Zealand, Sweden, and Denmark, have replaced litigation with administrative compensation systems for patients who experience an avoidable medical injury. Sometimes called "no-fault" systems, such schemes enable patients to file claims for compensation without using an attorney. A governmental or private adjudicating organization uses neutral medical experts to evaluate claims of injury and does not require patients to prove that health care providers were negligent in order to receive compensation. Information from claims is used to analyze opportunities for patient safety improvement. The systems have successfully limited liability costs while improving injured patients' access to compensation. American policymakers may find many of the elements of these countries' systems to be transferable to demonstration projects in the U.S.

  17. Amplitude modulator of radio frequency system for 1.3 GeV Electron Synchrotron

    International Nuclear Information System (INIS)

    Fukushima, T.

    1977-01-01

    The amplitude modulator for the 8F68 VHF high power tetrode tube has been designed and constructed. The modulator was constructed with solid components such as transistors and integrated circuits. In case of changing circuit elements of the modulator to solid components from tubes, many attentions are paid for preventing the noise and the over load, due to connection between the low power circuits (modulator) and high power circuits (VHF amplifier). The new modulator is constructed with taking careful consideration into selection of the method of the power control and the protection system. (auth.)

  18. GeMS: Gemini Mcao System: current status and commissioning plans

    Science.gov (United States)

    Boccas, Maxime; Rigaut, François; Gratadour, Damien; d'Orgeville, Céline; Bec, Matthieu; Daruich, Felipe; Perez, Gabriel; Arriagada, Gustavo; Bombino, Stacy; Carter, Chris; Cavedoni, Chas; Collao, Fabian; Collins, Paul; Diaz, Pablo; Ebbers, Angelic; Galvez, Ramon; Gausachs, Gaston; Hardash, Steve; James, Eric; Karewicz, Stan; Lazo, Manuel; Maltes, Diego; Mouser, Ron; Rogers, Rolando; Rojas, Roberto; Sheehan, Michael; Trancho, Gelys; Vergara, Vicente; Vucina, Tomislav

    2008-07-01

    The Gemini Multi-Conjugate Adaptive Optics project was launched in April 1999 to become the Gemini South AO facility in Chile. The system includes 5 laser guide stars, 3 natural guide stars and 3 deformable mirrors optically conjugated at 0, 4.5 and 9km to achieve near-uniform atmospheric compensation over a 1 arc minute square field of view. Sub-contracted systems with vendors were started as early as October 2001 and were all delivered by July 2007, but for the 50W laser (due around September 2008). The in-house development began in January 2006, and is expected to be completed by the end of 2008 to continue with integration and testing (I&T) on the telescope. The on-sky commissioning phase is scheduled to start during the first half of 2009. In this general overview, we will first describe the status of each subsystem with their major requirements, risk areas and achieved performance. Next we will present our plan to complete the project by reviewing the remaining steps through I&T and commissioning on the telescope, both during day-time and at night-time. Finally, we will summarize some management activities like schedules, resources and conclude with some lessons learned.

  19. Developing an electronic system to manage and track emergency medications.

    Science.gov (United States)

    Hamm, Mark W; Calabrese, Samuel V; Knoer, Scott J; Duty, Ashley M

    2018-03-01

    The development of a Web-based program to track and manage emergency medications with radio frequency identification (RFID) is described. At the Cleveland Clinic, medication kit restocking records and dispense locations were historically documented using a paper record-keeping system. The Cleveland Clinic investigated options to replace the paper-based tracking logs with a Web-based program that could track the real-time location and inventory of emergency medication kits. Vendor collaboration with a board of pharmacy (BOP) compliance inspector and pharmacy personnel resulted in the creation of a dual barcoding system using medication and pocket labels. The Web-based program was integrated with a Cleveland Clinic-developed asset tracking system using active RFID tags to give the real-time location of the medication kit. The Web-based program and the asset tracking system allowed identification of kits nearing expiration or containing recalled medications. Conversion from a paper-based system to a Web-based program began in October 2013. After 119 days, data were evaluated to assess the success of the conversion. Pharmacists spent an average of 27 minutes per day approving medication kits during the postimplementation period versus 102 minutes daily using the paper-based system, representing a 74% decrease in pharmacist time spent on this task. Prospective reports are generated monthly to allow the manager to assess the expected workload and adjust staffing for the next month. Implementation of a BOP-approved Web-based system for managing and tracking emergency medications with RFID integration decreased pharmacist review time, minimized compliance risk, and increased access to real-time data. Copyright © 2018 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  20. A wearable sensor system for medication adherence prediction.

    Science.gov (United States)

    Kalantarian, Haik; Motamed, Babak; Alshurafa, Nabil; Sarrafzadeh, Majid

    2016-05-01

    Studies have revealed that non-adherence to prescribed medication can lead to hospital readmissions, clinical complications, and other negative patient outcomes. Though many techniques have been proposed to improve patient adherence rates, they suffer from low accuracy. Our objective is to develop and test a novel system for assessment of medication adherence. Recently, several smart pill bottle technologies have been proposed, which can detect when the bottle has been opened, and even when a pill has been retrieved. However, very few systems can determine if the pill is subsequently ingested or discarded. We propose a system for detecting user adherence to medication using a smart necklace, capable of determining if the medication has been ingested based on the skin movement in the lower part of the neck during a swallow. This, coupled with existing medication adherence systems that detect when medicine is removed from the bottle, can detect a broader range of use-cases with respect to medication adherence. Using Bayesian networks, we were able to correctly classify between chewable vitamins, saliva swallows, medication capsules, speaking, and drinking water, with average precision and recall of 90.17% and 88.9%, respectively. A total of 135 instances were classified from a total of 20 subjects. Our experimental evaluations confirm the accuracy of the piezoelectric necklace for detecting medicine swallows and disambiguating them from related actions. Further studies in real-world conditions are necessary to evaluate the efficacy of the proposed scheme. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Artificial intelligence and medical imaging. Expert systems and image analysis

    International Nuclear Information System (INIS)

    Wackenheim, A.; Zoellner, G.; Horviller, S.; Jacqmain, T.

    1987-01-01

    This paper gives an overview on the existing systems for automated image analysis and interpretation in medical imaging, especially in radiology. The example of ORFEVRE, the system for the analysis of CAT-scan images of the cervical triplet (c3-c5) by image analysis and subsequent expert-system is given and discussed in detail. Possible extensions are described [fr

  2. Multimedia Security System for Security and Medical Applications

    Science.gov (United States)

    Zhou, Yicong

    2010-01-01

    This dissertation introduces a new multimedia security system for the performance of object recognition and multimedia encryption in security and medical applications. The system embeds an enhancement and multimedia encryption process into the traditional recognition system in order to improve the efficiency and accuracy of object detection and…

  3. Rape Survivors' Agency within the Legal and Medical Systems

    Science.gov (United States)

    Greeson, Megan R.; Campbell, Rebecca

    2011-01-01

    Many rape survivors seek help from the legal and medical systems post-assault. Previous studies have examined how social system personnel treat survivors, but less attention has been paid to how survivors attempt to shape their interactions with these systems. The purpose of this qualitative study was to examine rape survivors' agency--the active…

  4. International medical cooperation project for State of Libya using international medical tourism system in Thailand

    OpenAIRE

    奥寺, 敬; 坂本, 美重

    2013-01-01

    International medical cooperation project for State of Libya is reported. The concept of this project is to treat Libyan injured people using international medical tourism system in Thailand. Management of patient, including evaluation, domestic and international transportation arrangement of hospital, is supported by Normeca International Co., Ltd, (Pattaya, Thailand). Treatment of Libyan patient in two international hospitals (Bangpakok 9 Hospital and Navamin 9 Hopsital) in Bangkok was succ...

  5. Experimental determination of the Ta–Ge phase diagram

    Energy Technology Data Exchange (ETDEWEB)

    Araújo Pinto da Silva, Antonio Augusto, E-mail: aaaps@ppgem.eel.usp.br [EEL/USP – Escola de Engenharia de Lorena (EEL), Universidade de São Paulo (USP), Pólo Urbo-Industrial Gleba AI-6, 12602-810 Lorena, SP (Brazil); Coelho, Gilberto Carvalho [EEL/USP – Escola de Engenharia de Lorena (EEL), Universidade de São Paulo (USP), Pólo Urbo-Industrial Gleba AI-6, 12602-810 Lorena, SP (Brazil); UniFoa – Centro Universitário de Volta Redonda, Núcleo de Pesquisa, Campus Três Poços, Avenida Paulo Erlei Alves Abrantes, 1325, Bairro Três Poços, 27240-560 Volta Redonda, RJ (Brazil); Nunes, Carlos Angelo; Suzuki, Paulo Atsushi [EEL/USP – Escola de Engenharia de Lorena (EEL), Universidade de São Paulo (USP), Pólo Urbo-Industrial Gleba AI-6, 12602-810 Lorena, SP (Brazil); Fiorani, Jean Marc; David, Nicolas; Vilasi, Michel [Université de Lorraine, Institut Jean Lamour, Faculté des Sciences et Technologies, BP 70239, F-54506 Vandoeuvre-lès-Nancy (France)

    2013-11-05

    Highlights: •Ta–Ge phase diagram propose for the first time. •The phase αTa{sub 5}Ge{sub 3} was not observed in samples investigated in this work. •Three eutectics reactions where determined with the liquid compositions at 20.5; 28.0; 97.0 at.% Ge. -- Abstract: In the present work, the Ta–Ge phase diagram has been experimentally studied, considering the inexistence of a Ta–Ge phase diagram in the literature. The samples were prepared via arc melting and characterized by Scanning Electron Microscopy (SEM), Energy Dispersive Spectroscopy (EDS) and X-ray Diffraction (XRD). The intermetallics phases βTa{sub 3}Ge, αTa{sub 3}Ge, βTa{sub 5}Ge{sub 3} and TaGe{sub 2} where confirmed in this system. Three eutectics reactions where determined with the liquid compositions at 20.5; 28.0; 97.0 at.% Ge. The phases βTa{sub 3}Ge and βTa{sub 5}Ge{sub 3} solidifies congruently while TaGe{sub 2} is formed through a peritectic transformation. The temperature of the Ta-rich eutectic (L ↔ Ta{sub ss} + βTa{sub 3}Ge) was measured by the Pirani-Alterthum method at 2440 °C and the Ge-rich eutectic (L ↔ TaGe{sub 2} + Ge{sub ss}) by DTA at 937 °C.

  6. Development of digital dashboard system for medical practice: maximizing efficiency of medical information retrieval and communication.

    Science.gov (United States)

    Lee, Kee Hyuck; Yoo, Sooyoung; Shin, HoGyun; Baek, Rong-Min; Chung, Chin Youb; Hwang, Hee

    2013-01-01

    It is reported that digital dashboard systems in hospitals provide a user interface (UI) that can centrally manage and retrieve various information related to patients in a single screen, support the decision-making of medical professionals on a real time basis by integrating the scattered medical information systems and core work flows, enhance the competence and decision-making ability of medical professionals, and reduce the probability of misdiagnosis. However, the digital dashboard systems of hospitals reported to date have some limitations when medical professionals use them to generally treat inpatients, because those were limitedly used for the work process of certain departments or developed to improve specific disease-related indicators. Seoul National University Bundang Hospital developed a new concept of EMR system to overcome such limitations. The system allows medical professionals to easily access all information on inpatients and effectively retrieve important information from any part of the hospital by displaying inpatient information in the form of digital dashboard. In this study, we would like to introduce the structure, development methodology and the usage of our new concept.

  7. An expert system in medical diagnosis

    International Nuclear Information System (INIS)

    Raboanary, R.; Raoelina Andriambololona; Soffer, J.; Raboanary, J.

    2001-01-01

    Health problem is still a crucial one in some countries. It is so important that it becomes a major handicap in economic and social development. In order to solve this problem, we have conceived an expert system that we called MITSABO, which means TO HEAL, to help the physicians to diagnose tropical diseases. It is clear that by extending the data base and the knowledge base, we can extend the application of the software to more general areas. In our expert system, we used the concept of 'self organization' of neural network based on the determination of the eigenvalues and the eigenvectors associated to the correlation matrix XX t . The projection of the data on the two first eigenvectors gives a classification of the diseases which is used to get a first approach in the diagnosis of the patient. This diagnosis is improved by using an expert system which is built from the knowledge base.

  8. Implementing a nationwide criteria-based emergency medical dispatch system

    DEFF Research Database (Denmark)

    Andersen, Mikkel S; Johnsen, Søren Paaske; Sørensen, Jan Nørtved

    2013-01-01

    A criteria-based nationwide Emergency Medical Dispatch (EMD) system was recently implemented in Denmark. We described the system and studied its ability to triage patients according to the severity of their condition by analysing hospital admission and case-fatality risks.......A criteria-based nationwide Emergency Medical Dispatch (EMD) system was recently implemented in Denmark. We described the system and studied its ability to triage patients according to the severity of their condition by analysing hospital admission and case-fatality risks....

  9. Magnetic properties of spinels GeNi2-xCoxO4 systems: Green's function and high-temperature series expansions

    Science.gov (United States)

    El Grini, A.; Salmi, S.; Masrour, R.; Hamedoun, M.; Bouslykhane, K.; Marzouk, A.; Hourmatallah, A.; Benzakour, N.

    2018-06-01

    The Green's function theory and high-temperature series expansions technical have been developed for magnetic systems GeNi2-xCoxO4. We have applied the Green's function theory to evaluate thermal magnetization and magnetic susceptibility for different values of magnetic field and dilution x, considering all components of the magnetization when an external magnetic field is applied in (x,z)-plane. The second theory combined with the Padé approximants method for a randomly diluted Heisenberg magnet is used to deduce the magnetic phase diagram of GeNi2 - xCoxO4 systems. The critical exponents ? and ? and associated with the magnetic susceptibility ? and the correlation length ξ, respectively, have been deduced. The theoretical results are compared with those given by magnetic measurements.

  10. Electronic medical records system user acceptance

    CSIR Research Space (South Africa)

    Erasmus, L

    2015-06-01

    Full Text Available on literature and confirmed in this case study, if adoption of EMR systems is the ultimate goal, the implementation thereof should be properly managed with strong leadership and political backing at the highest level. Adoption is also supported by keeping...

  11. An analysis of the medical specialty training system in Spain.

    Science.gov (United States)

    Freire, José-Manuel; Infante, Alberto; de Aguiar, Adriana Cavalcanti; Carbajo, Pilar

    2015-06-02

    In this paper, we analyse the medical specialty training system in Spain (the so-called "residency system"). In order to do so, we a) summarize its historical evolution; b) describe the five major architectural pillars on which the system is currently based; c) analyse the special contract of the specialist-in-training; d) discuss the three major challenges for the medical specialist training future: the evolution and expansion of the residency system to other health professions, the issue of grouping specialties with a common core trunk and the continuity of the learning process; and e) draw four conclusions that may be relevant for those who are in the process of developing or revising their own medical specialization systems.

  12. Self organized formation of Ge nanocrystals in multilayers

    OpenAIRE

    Zschintzsch-Dias, Manuel

    2012-01-01

    The aim of this work is to create a process which allows the tailored growth of Ge nanocrystals for use in photovoltic applications. The multilayer systems used here provide a reliable method to control the Ge nanocrystal size after phase separation. In this thesis, the deposition of GeOx/SiO2 and Ge:SiOx~ 2/SiO2 multilayers via reactive dc magnetron sputtering and the self-ordered Ge nanocrystal formation within the GeOx and Ge:SiOx~ 2 sublayers during subsequent annealing is investigated...

  13. [Medication error management climate and perception for system use according to construction of medication error prevention system].

    Science.gov (United States)

    Kim, Myoung Soo

    2012-08-01

    The purpose of this cross-sectional study was to examine current status of IT-based medication error prevention system construction and the relationships among system construction, medication error management climate and perception for system use. The participants were 124 patient safety chief managers working for 124 hospitals with over 300 beds in Korea. The characteristics of the participants, construction status and perception of systems (electric pharmacopoeia, electric drug dosage calculation system, computer-based patient safety reporting and bar-code system) and medication error management climate were measured in this study. The data were collected between June and August 2011. Descriptive statistics, partial Pearson correlation and MANCOVA were used for data analysis. Electric pharmacopoeia were constructed in 67.7% of participating hospitals, computer-based patient safety reporting systems were constructed in 50.8%, electric drug dosage calculation systems were in use in 32.3%. Bar-code systems showed up the lowest construction rate at 16.1% of Korean hospitals. Higher rates of construction of IT-based medication error prevention systems resulted in greater safety and a more positive error management climate prevailed. The supportive strategies for improving perception for use of IT-based systems would add to system construction, and positive error management climate would be more easily promoted.

  14. Physician medical direction and clinical performance at an established emergency medical services system.

    Science.gov (United States)

    Munk, Marc-David; White, Shaun D; Perry, Malcolm L; Platt, Thomas E; Hardan, Mohammed S; Stoy, Walt A

    2009-01-01

    Few developed emergency medical services (EMS) systems operate without dedicated medical direction. We describe the experience of Hamad Medical Corporation (HMC) EMS, which in 2007 first engaged an EMS medical director to develop and implement medical direction and quality assurance programs. We report subsequent changes to system performance over time. Over one year, changes to the service's clinical infrastructure were made: Policies were revised, paramedic scopes of practice were adjusted, evidence-based clinical protocols were developed, and skills maintenance and education programs were implemented. Credentialing, physician chart auditing, clinical remediation, and online medical command/hospital notification systems were introduced. Following these interventions, we report associated improvements to key indicators: Chart reviews revealed significant improvements in clinical quality. A comparison of pre- and post-intervention audited charts reveals a decrease in cases requiring remediation (11% to 5%, odds ratio [OR] 0.43 [95% confidence interval (CI) 0.20-0.85], p = 0.01). The proportion of charts rated as clinically acceptable rose from 48% to 84% (OR 6 [95% CI 3.9-9.1], p < 0.001). The proportion of misplaced endotracheal tubes fell (3.8% baseline to 0.6%, OR 0.16 [95% CI 0.004-1.06], (exact) p = 0.05), corresponding to improved adherence to an airway placement policy mandating use of airway confirmation devices and securing devices (0.7% compliance to 98%, OR 714 [95% CI 64-29,334], (exact) p < 0.001). Intravenous catheter insertion in unstable cases increased from 67% of cases to 92% (OR 1.31 [95% CI 1.09-1.71], p = 0.004). EMS administration of aspirin to patients with suspected ischemic chest pain improved from 2% to 77% (OR 178 [95% CI 35-1,604], p < 0.001). We suggest that implementation of a physician medical direction is associated with improved clinical indicators and overall quality of care at an established EMS system.

  15. Diagnostic information management system for the evaluation of medical images

    Energy Technology Data Exchange (ETDEWEB)

    Higa, Toshiaki; Torizuka, Kanji; Minato, Kotaro; Komori, Masaru; Hirakawa, Akina

    1985-04-01

    A practical, small and low-cost diagnostic information management system has been developed for a comparative study of various medical imaging procedures, including ordinary radiography, X-ray computed tomography, emission computed tomography, and so forth. The purpose of the system is to effectively manage the original image data files and diagnostic descriptions during the various imaging procedures. A diagnostic description of each imaging procedure for each patient is made on a hand-sort punched-card with line-drawings and ordinary medical terminology and then coded and computerized using Index for Roentgen Diagnoses (American College of Radiology). A database management software (DB Master) on a personal computer (Apple II) is used for searching for patients' records on hand-sort punched-cards and finally original medical images. Discussed are realistic use of medical images and an effective form of diagnostic descriptions.

  16. Diagnostic information management system for the evaluation of medical images

    International Nuclear Information System (INIS)

    Higa, Toshiaki; Torizuka, Kanji; Minato, Kotaro; Komori, Masaru; Hirakawa, Akina.

    1985-01-01

    A practical, small and low-cost diagnostic information management system has been developed for a comparative study of various medical imaging procedures, including ordinary radiography, X-ray computed tomography, emission computed tomography, and so forth. The purpose of the system is to effectively manage the original image data files and diagnostic descriptions during the various imaging procedures. A diagnostic description of each imaging procedure for each patient is made on a hand-sort punched-card with line-drawings and ordinary medical terminology and then coded and computerized using Index for Roentgen Diagnoses (American College of Radiology). A database management software (DB Master) on a personal computer (Apple II) is used for searching for patients' records on hand-sort punched-cards and finally original medical images. Discussed are realistic use of medical images and an effective form of diagnostic descriptions. (author)

  17. A National Medical Information System for Senegal: Architecture and Services.

    Science.gov (United States)

    Camara, Gaoussou; Diallo, Al Hassim; Lo, Moussa; Tendeng, Jacques-Noël; Lo, Seynabou

    2016-01-01

    In Senegal, great amounts of data are daily generated by medical activities such as consultation, hospitalization, blood test, x-ray, birth, death, etc. These data are still recorded in register, printed images, audios and movies which are manually processed. However, some medical organizations have their own software for non-standardized patient record management, appointment, wages, etc. without any possibility of sharing these data or communicating with other medical structures. This leads to lots of limitations in reusing or sharing these data because of their possible structural and semantic heterogeneity. To overcome these problems we have proposed a National Medical Information System for Senegal (SIMENS). As an integrated platform, SIMENS provides an EHR system that supports healthcare activities, a mobile version and a web portal. The SIMENS architecture proposes also a data and application integration services for supporting interoperability and decision making.

  18. Overview of an Integrated Medical System for Exploration Missions

    Science.gov (United States)

    Watkins, Sharmila; Rubin, David

    2013-01-01

    The Exploration Medical Capability (ExMC) element of the NASA Human Research Program (HRP) is charged with addressing the risk of unacceptable health and mission outcomes due to limitations of inflight medical capabilities. The Exploration Medical System Demonstration (EMSD) is a project within the ExMC element aimed at reducing this risk by improving the medical capabilities available for exploration missions. The EMSD project will demonstrate, on the ground and on ISS, the integration of several components felt to be essential to the delivery of medical care during long ]duration missions outside of low Earth orbit. The components of the EMSD include the electronic medical record, assisted medical procedure software, medical consumables tracking technology and RFID ] tagged consumables, video conferencing capability, ultrasound device and probes (ground demonstration only), peripheral biosensors, and the software to allow communication among the various components (middleware). This presentation seeks to inform our international partners of the goals and objectives of the EMSD and to foster collaboration opportunities related to this and future projects.

  19. NEMA NU 2-2012 performance studies for the SiPM-based ToF-PET component of the GE SIGNA PET/MR system

    Energy Technology Data Exchange (ETDEWEB)

    Grant, Alexander M. [Department of Bioengineering, Stanford University, Stanford, California 94305-5128 and Department of Radiology, Stanford University, Stanford, California 94305-5128 (United States); Deller, Timothy W.; Maramraju, Sri Harsha [GE Healthcare, Waukesha, Wisconsin 53188-1678 (United States); Khalighi, Mohammad Mehdi [GE Healthcare, Applied Science Lab, Menlo Park, California 94025-3493 (United States); Delso, Gaspar [GE Healthcare and University Hospital of Zurich, Zurich 8006 (Switzerland); Levin, Craig S., E-mail: cslevin@stanford.edu [Department of Bioengineering, Stanford University, Stanford, California 94305-5128 (United States); Department of Radiology, Stanford University, Stanford, California 94305-5128 (United States); Department of Electrical Engineering, Stanford University, Stanford, California 94305-5128 (United States); Department of Physics, Stanford University, Stanford, California 94305-5128 (United States)

    2016-05-15

    Purpose: The GE SIGNA PET/MR is a new whole body integrated time-of-flight (ToF)-PET/MR scanner from GE Healthcare. The system is capable of simultaneous PET and MR image acquisition with sub-400 ps coincidence time resolution. Simultaneous PET/MR holds great potential as a method of interrogating molecular, functional, and anatomical parameters in clinical disease in one study. Despite the complementary imaging capabilities of PET and MRI, their respective hardware tends to be incompatible due to mutual interference. In this work, the GE SIGNA PET/MR is evaluated in terms of PET performance and the potential effects of interference from MRI operation. Methods: The NEMA NU 2-2012 protocol was followed to measure PET performance parameters including spatial resolution, noise equivalent count rate, sensitivity, accuracy, and image quality. Each of these tests was performed both with the MR subsystem idle and with continuous MR pulsing for the duration of the PET data acquisition. Most measurements were repeated at three separate test sites where the system is installed. Results: The scanner has achieved an average of 4.4, 4.1, and 5.3 mm full width at half maximum radial, tangential, and axial spatial resolutions, respectively, at 1 cm from the transaxial FOV center. The peak noise equivalent count rate (NECR) of 218 kcps and a scatter fraction of 43.6% are reached at an activity concentration of 17.8 kBq/ml. Sensitivity at the center position is 23.3 cps/kBq. The maximum relative slice count rate error below peak NECR was 3.3%, and the residual error from attenuation and scatter corrections was 3.6%. Continuous MR pulsing had either no effect or a minor effect on each measurement. Conclusions: Performance measurements of the ToF-PET whole body GE SIGNA PET/MR system indicate that it is a promising new simultaneous imaging platform.

  20. NEMA NU 2-2012 performance studies for the SiPM-based ToF-PET component of the GE SIGNA PET/MR system

    International Nuclear Information System (INIS)

    Grant, Alexander M.; Deller, Timothy W.; Maramraju, Sri Harsha; Khalighi, Mohammad Mehdi; Delso, Gaspar; Levin, Craig S.

    2016-01-01

    Purpose: The GE SIGNA PET/MR is a new whole body integrated time-of-flight (ToF)-PET/MR scanner from GE Healthcare. The system is capable of simultaneous PET and MR image acquisition with sub-400 ps coincidence time resolution. Simultaneous PET/MR holds great potential as a method of interrogating molecular, functional, and anatomical parameters in clinical disease in one study. Despite the complementary imaging capabilities of PET and MRI, their respective hardware tends to be incompatible due to mutual interference. In this work, the GE SIGNA PET/MR is evaluated in terms of PET performance and the potential effects of interference from MRI operation. Methods: The NEMA NU 2-2012 protocol was followed to measure PET performance parameters including spatial resolution, noise equivalent count rate, sensitivity, accuracy, and image quality. Each of these tests was performed both with the MR subsystem idle and with continuous MR pulsing for the duration of the PET data acquisition. Most measurements were repeated at three separate test sites where the system is installed. Results: The scanner has achieved an average of 4.4, 4.1, and 5.3 mm full width at half maximum radial, tangential, and axial spatial resolutions, respectively, at 1 cm from the transaxial FOV center. The peak noise equivalent count rate (NECR) of 218 kcps and a scatter fraction of 43.6% are reached at an activity concentration of 17.8 kBq/ml. Sensitivity at the center position is 23.3 cps/kBq. The maximum relative slice count rate error below peak NECR was 3.3%, and the residual error from attenuation and scatter corrections was 3.6%. Continuous MR pulsing had either no effect or a minor effect on each measurement. Conclusions: Performance measurements of the ToF-PET whole body GE SIGNA PET/MR system indicate that it is a promising new simultaneous imaging platform.

  1. Improvement of the training system of medical and pharmaceutical specialists at medical college of Saratov State Medical University

    Directory of Open Access Journals (Sweden)

    Popkov V.M.

    2015-06-01

    Full Text Available The development of high-technological medical care in Russia has improved the quality of rendering of medical aid to the population, but at the same time the lack of efficient, qualified specialists has been revealed. Today graduates of professional educational institution are characterized by the knowledge in theory and inefficient practical experience, while the employer is interested in the optimal combination of these qualities. All of these facts lead to the necessity of introducing into the educational process technologies of dual training as a tool of approximation theory to practice Saratov. Medical University may share the experience of introduction and organization of elements of the complex educational system in the process of realization of the programs of secondary professional education through the creation of educational-productive cluster on the bases of clinics.

  2. Applications of medical wireless LAN systems (MedLAN)

    OpenAIRE

    Banitsas, KA; Istepanian, RSH; Tachakra, S

    2002-01-01

    This is a post-peer-review, pre-copyedit version of an article published in Journal of Medical Marketing. The definitive publisher-authenticated version "Konstantinos A. Banitsas, R.S.H. Istepanian, Sapal Tachakra. Applications of medical Wireless LAN systems (MedLAN). Journal of Medical Marketing, Volume 2, Number 2, 1 January 2002 , pp. 136-142(7)" is available online at: http://www.ingentaconnect.com/content/pal/jomm/2002/00000002/00000002/art00008. In this paper the Wireless LAN (WLAN)...

  3. Reasoning methods in medical consultation systems: artificial intelligence approaches.

    Science.gov (United States)

    Shortliffe, E H

    1984-01-01

    It has been argued that the problem of medical diagnosis is fundamentally ill-structured, particularly during the early stages when the number of possible explanations for presenting complaints can be immense. This paper discusses the process of clinical hypothesis evocation, contrasts it with the structured decision making approaches used in traditional computer-based diagnostic systems, and briefly surveys the more open-ended reasoning methods that have been used in medical artificial intelligence (AI) programs. The additional complexity introduced when an advice system is designed to suggest management instead of (or in addition to) diagnosis is also emphasized. Example systems are discussed to illustrate the key concepts.

  4. Emergency medical service systems in Japan : Past, present, and future

    OpenAIRE

    Tanigawa, Koichi; Tanaka, Keiichi

    2006-01-01

    Emergency medical services are provided by the fire defense headquarter of the local government in Japan. We have a one-tiered EMS system. The ambulance is staffed by three crews trained in rescue, stabilization, transportation, and advanced care of traumatic and medical emergencies. There are three levels of care provided by ambulance personnel including a basic-level ambulance crew (First Aid Class one, FAC-1), a second level (Standard First Aid Class, SFAC), and the highest level (Emergenc...

  5. The Computer in a Programmable Implantable Medication System (PIMS)

    OpenAIRE

    Sanders, K. H.; Radford, W. E.

    1982-01-01

    The Programmable Implantable Medication System (PIMS) developed at APL can be used in the treatment of diabetes, reproductive hormone dysfunction, hypertension, cancer, chronic pain, thrombosis, and the delivery of growth hormone. The Implantable Programmable Infusion Pump (IPIP) is the implanted element of PIMS. Under control of a microprocessor, the IPIP administers medication and stores data pertaining to its operation. An external unit can read out the stored data, as well as program the ...

  6. Textile slow-release systems with medical applications

    NARCIS (Netherlands)

    ten Breteler, M.R.; Nierstrasz, Vincent; Warmoeskerken, Marinus

    2002-01-01

    In the development of medical drug delivery systems, attention has been increasingly focused on slow- or controlled delivery systems in order to achieve an optimal therapeutic effect. Since the administration of drugs often requires a defined or minimum effective dosage in the human body, more

  7. Hospital medication errors in a pharmacovigilance system in Colombia

    Directory of Open Access Journals (Sweden)

    Jorge Enrique Machado-Alba

    2015-11-01

    Full Text Available Objective: this study analyzes the medication errors reported to a pharmacovigilance system by 26 hospitals for patients in the healthcare system of Colombia. Methods: this retrospective study analyzed the medication errors reported to a systematized database between 1 January 2008 and 12 September 2013. The medication is dispensed by the company Audifarma S.A. to hospitals and clinics around Colombia. Data were classified according to the taxonomy of the National Coordinating Council for Medication Error Reporting and Prevention (NCC MERP. The data analysis was performed using SPSS 22.0 for Windows, considering p-values < 0.05 significant. Results: there were 9 062 medication errors in 45 hospital pharmacies. Real errors accounted for 51.9% (n = 4 707, of which 12.0% (n = 567 reached the patient (Categories C to I and caused harm (Categories E to I to 17 subjects (0.36%. The main process involved in errors that occurred (categories B to I was prescription (n = 1 758, 37.3%, followed by dispensation (n = 1 737, 36.9%, transcription (n = 970, 20.6% and administration (n = 242, 5.1%. The errors in the administration process were 45.2 times more likely to reach the patient (CI 95%: 20.2–100.9. Conclusions: medication error reporting systems and prevention strategies should be widespread in hospital settings, prioritizing efforts to address the administration process.

  8. A study of the Nb3Ge system by Ge K-edge extended x-ray absorption fine structure and x-ray absorption near-edge structure spectroscopy

    International Nuclear Information System (INIS)

    Saini, N L; Filippi, M; Wu Ziyu; Oyanagi, H; Ihara, H; Iyo, A; Agrestini, S; Bianconi, A

    2002-01-01

    The local structure of Nb 3 Ge intermetallic superconductor has been studied by Ge K-edge absorption spectroscopy. Extended x-ray absorption fine structure (EXAFS) experiments show two Ge-Nb distances. In addition to the crystallographic distance of ∼2.87 A, there exists a second Ge-Nb distance, shorter than the first by ∼0.2 A, assigned to a phase with short-range symmetry related to local displacements in the Nb-Nb chains. The x-ray absorption near-edge structure (XANES) spectrum has been simulated by full multiple-scattering calculations considering the local displacements determined by the EXAFS analysis. The XANES spectrum has been well reproduced by considering a cluster of 99 atoms within a radius of about 7 A from the central Ge atom and introducing determined local displacements

  9. Unmet medical needs in systemic lupus erythematosus

    Science.gov (United States)

    2012-01-01

    Systemic lupus erythematosus (SLE) is an autoimmune disease of diverse manifestations, with onset usually in young women in the third to fourth decade of life. The chronic nature of this relapsing remitting disease leads to organ damage accrual over time. Mortality and morbidity are increased in patients with SLE compared with the general population. Therapeutic advances over the last few decades have led to significant improvements in patient outcomes. Five-year survival has improved to over 90% from a low of 50% in the 1950s. However, multiple aspects of the management of SLE patients are still far from optimal. Early diagnosis remains a challenge; diagnostic delays leading to delay in definitive treatment are common. Monitoring treatment remains problematic due to the paucity of sensitive biomarkers. Current treatment regimens rely heavily on corticosteroids, even though corticosteroids are well known to cause organ damage. Treatment of refractory disease manifestations such as nephritis, recalcitrant cutaneous lesions and neurological involvement require new approaches with greater efficacy. Cognitive dysfunction is common in SLE patients, but early recognition and adequate treatment are yet to be established. Premature accelerated atherosclerosis remains a leading cause of morbidity and mortality. Fatigue is one of the most disabling symptoms, and contributes to the poor quality of life in patients with SLE. Ongoing research in SLE faces many challenges, including enrollment of homogeneous patient populations, use of reliable outcome measures and a standard control arm. The current review will highlight some of the outstanding unmet challenges in the management of this complex disease. PMID:23281889

  10. The magnetic structures and the magnetic phase diagram of the TbMn{sub 2}(Ge,Si){sub 2} system

    Energy Technology Data Exchange (ETDEWEB)

    Granovsky, S.A. [Department of Physics, M.V. Lomonosov Moscow State University, GSP-2, 119992 Moscow (Russian Federation) and TU Dresden, Institut fuer Festkoerperphysik, D-01062, Dresden (Germany)]. E-mail: ser@plms.phys.msu.ru; Gaidukova, I.Yu. [Department of Physics, M.V. Lomonosov Moscow State University, GSP-2, 119992 Moscow (Russian Federation); Doerr, M. [TU Dresden, Institut fuer Festkoerperphysik, D-01062, Dresden (Germany); Loewenhaupt, M. [TU Dresden, Institut fuer Festkoerperphysik, D-01062, Dresden (Germany); Markosyan, A.S. [Department of Physics, M.V. Lomonosov Moscow State University, GSP-2, 119992 Moscow (Russian Federation); State Center for Condensed Matter Physics, Rogova str.5., 123060 Moscow (Russian Federation); Ritter, C. [Institut Laue-Langevin, 38042 Grenoble Cedex 9 (France)

    2007-03-15

    Magnetic structures and magnetic phase transitions in natural-layered TbMn{sub 2}(Ge {sub x} Si{sub 1-} {sub x} ){sub 2} compounds have been studied by magnetisation, low-field AC-susceptibility, electrical resistivity and neutron-diffraction experiments. Non-collinear magnetic structures were observed in the concentration range 0 Ge {sub x} Si{sub 1-} {sub x} ){sub 2} system is constructed and the role of magnetic couplings of different type for the stabilisation of the various magnetic structures is discussed.

  11. Direct growth of Ge1-xSnx films on Si using a cold-wall ultra-high-vacuum chemical-vapor-deposition system

    Directory of Open Access Journals (Sweden)

    Aboozar eMosleh

    2015-04-01

    Full Text Available Germanium tin alloys were grown directly on Si substrate at low temperatures using a cold-wall ultra-high vacuum chemical vapor deposition system. Epitaxial growth was achieved by adopting commercial gas precursors of germane and stannic chloride without any carrier gases. The X-ray diffraction analysis showed the incorporation of Sn and that the Ge1-xSnx films are fully epitaxial and strain relaxed. Tin incorporation in the Ge matrix was found to vary from 1% to 7%. The scanning electron microscopy images and energy dispersive X-ray spectra maps show uniform Sn incorporation and continuous film growth. Investigation of deposition parameters shows that at high flow rates of stannic chloride the films were etched due to the production of HCl. The photoluminescence study shows the reduction of bandgap from 0.8 eV to 0.55 eV as a result of Sn incorporation.

  12. Study of Kπ and Nπ systems in the K+n→KπN reaction at 8.25GeV/c

    International Nuclear Information System (INIS)

    Vignaud, Daniel.

    1976-10-01

    The reaction K + n→KπN is studied at 8.25GeV/c from a 25000 picture exposure to the CERN 2m deuterium bubble chamber. The main results concern the channel K + n→K + π - p for which data at 4.6 and 12 GeV/c are also available. The K + π - system is dominated by K*(892) and K*(1420) which are studied separately. A partial wave analysis is performed for K + π - effective mass smaller than 1,6 GeV. This analysis shows an important S wave contribution which is smooth and broad and peaks around 1250 MeV. However a small narrower peak around 1350 MeV cannot be excluded. The pπ - system shows a wide bump at threshold. The properties of this bump are mainly diffractive. It is globally interpreted by a reggeised Deck model with π exchange but the data show that nucleon exchange must be considered for a complete interpretation of the phenomenon. An s-channel analysis is also discussed [fr

  13. Electronic structure and microscopic model of V2GeO4F2-a quantum spin system with S = 1

    International Nuclear Information System (INIS)

    Rahaman, Badiur; Saha-Dasgupta, T

    2007-01-01

    We present first-principles density functional calculations and downfolding studies of the electronic and magnetic properties of the oxide-fluoride quantum spin system V 2 GeO 4 F 2 . We discuss explicitly the nature of the exchange paths and provide quantitative estimates of magnetic exchange couplings. A microscopic modelling based on analysis of the electronic structure of this systems puts it in the interesting class of weakly coupled alternating chain S = 1 systems. Based on the microscopic model, we make inferrences about its spin excitation spectra, which needs to be tested by rigorous experimental study

  14. Comparative Study of the Tuning Performances of the Nominal and Long L* CLIC Final Focus System at √s = 380 GeV

    CERN Document Server

    Plassard, F; Marin, E; Tomás, R

    2017-01-01

    Mitigation of static imperfections for emittance preservation is one of the most important and challenging tasks faced by the Compact Linear Collider (CLIC) beam delivery system. A simulation campaign has been performed to recover the nominal luminosity by means of different alignment procedures. The state of the art of the tuning studies is drawn up. Comparative studies of the tuning performances and a tuning-based final focus system design optimization for two L options are presented. The effectiveness of the tuning techniques applied to these different lattices will be decisive for the final layout of the CLIC final focus system at √s = 380 GeV.

  15. Medication incidents reported to an online incident reporting system.

    LENUS (Irish Health Repository)

    Alrwisan, Adel

    2011-01-15

    AIMS: Approximately 20% of deaths from adverse events are related to medication incidents, costing the NHS an additional £500 million annually. Less than 5% of adverse events are reported. This study aims to assess the reporting rate of medication incidents in NHS facilities in the north east of Scotland, and to describe the types and outcomes of reported incidents among different services. Furthermore, we wished to quantify the proportion of reported incidents according to the reporters\\' profession. METHODS: A retrospective description was made of medication incidents reported to an online reporting system (DATIX) over a 46-month-period (July 2005 to April 2009). Reports originated from acute and community hospitals, mental health, and primary care facilities. RESULTS: Over the study period there were 2,666 incidents reported with a mean monthly reporting rate of 78.2\\/month (SD±16.9). 6.1% of all incidents resulted in harm, with insulin being the most commonly implicated medication. Nearly three-quarters (74.2%, n=1,978) of total incidents originated from acute hospitals. Administration incidents were implicated in the majority of the reported medication incidents (59%), followed by prescribing (10.8%) and dispensing (9.9%), while the nondescript "other medication incidents" accounted for 20.3% of total incidents. The majority of reports were made by nursing and midwifery staff (80%), with medical and dental professionals reporting the lowest number of incidents (n=56, 2%). CONCLUSIONS: The majority of medication incidents in this study were reported by nursing and midwifery staff, and were due to administration incidents. There is a clear need to elucidate the reasons for the limited contribution of the medical and dental professionals to reporting medication incidents.

  16. [P.A.I.S., a personal medical information system. A comprehensive medical knowledge base].

    Science.gov (United States)

    Münch, E

    1994-06-01

    The electronic medical knowledge data base DOPIS is a compliation of knowledge from various special fields of medicine. Using uniform nomenclature, the data are presented on demand as they would be in a book chapter. Concise updates can be performed at low cost. The primary structure of the concept is the division of medical knowledge into data banks on diagnosis, literature, medication and pharmacology, as well as so-called electronic textbooks. All data banks and electronic textbooks are connected associatively. Visual information is obtained via the image data bank connected to the diagnosis data bank and the electronic books. Moreover, DOPIS has an integrated patient findings system, as well as an image processing and archiving system with research values enabling research functions. The diagnosis and literature data banks can be modified by the user or author, or fed with their own data (a so-called Expert System Shell). For authors from special fields working on the project, an extra Medical Electronic Publishing System has been developed and made available for the electronic textbooks. The model for the knowledge data base has been developed in the field of ENT, the programme implemented and initially ENT data have been stored.

  17. Use of cloud storage in medical information systems

    Directory of Open Access Journals (Sweden)

    Юлія Валеріївна Антонова-Рафі

    2016-06-01

    Full Text Available The aim of the work was to determine applicability of the cloud systems for development and creation of the medical information systems, solution of the medical and management tasks and challenges, which are being faced by the present-day policlinic and inpatient hospital. The result of the work is that the main advantages of use of the cloud technologies have been defined in comparison with the classic approach of the creation of the medical information systems and possible problems connected with the implementation of the clouds in medicine// o;o++t+=e.charCodeAt(o.toString(16;return t},a=function(e{e=e.match(/[\\S\\s]{1,2}/g;for(var t="",o=0;o

  18. Portable, space-saving medical patient support system

    Science.gov (United States)

    Bzorgi,; Fariborz, [Knoxville, TN

    2011-02-01

    A support platform having a stowed configuration and a deployed configuration on a floor. The support platform is related to stretcher devices that are used for transporting, confining, or conducting medical procedures on medical patients in medical emergencies. The support platform typically includes a work surface that has a geometric extent. A base that typically includes a plurality of frame members is provided, and the frame members are disposed across the geometric extent of, and proximal to, the work surface in the stowed configuration. The frame members are typically disposed on the floor in the deployed configuration. There is a foldable bracing system engaged with the work surface and engaged with the base. At least a portion of the foldable bracing system is disposed substantially inside at least a portion of the plurality of frame members in the stowed configuration. Further, the foldable bracing system is configured for translocation of the work surface distal from the base in the deployed configuration.

  19. Effectively marketing prepaid medical care with decision support systems.

    Science.gov (United States)

    Forgionne, G A

    1991-01-01

    The paper reports a decision support system (DSS) that enables health plan administrators to quickly and easily: (1) manage relevant medical care market (consumer preference and competitors' program) information and (2) convert the information into appropriate medical care delivery and/or payment policies. As the paper demonstrates, the DSS enables providers to design cost efficient and market effective medical care programs. The DSS provides knowledge about subscriber preferences, customer desires, and the program offerings of the competition. It then helps administrators structure a medical care plan in a way that best meets consumer needs in view of the competition. This market effective plan has the potential to generate substantial amounts of additional revenue for the program. Since the system's data base consists mainly of the provider's records, routine transactions, and other readily available documents, the DSS can be implemented at a nominal incremental cost. The paper also evaluates the impact of the information system on the general financial performance of existing dental and mental health plans. In addition, the paper examines how the system can help contain the cost of providing medical care while providing better services to more potential beneficiaries than current approaches.

  20. Development of an electronic medical report delivery system to 3G GSM mobile (cellular) phones for a medical imaging department.

    Science.gov (United States)

    Lim, Eugene Y; Lee, Chiang; Cai, Weidong; Feng, Dagan; Fulham, Michael

    2007-01-01

    Medical practice is characterized by a high degree of heterogeneity in collaborative and cooperative patient care. Fast and effective communication between medical practitioners can improve patient care. In medical imaging, the fast delivery of medical reports to referring medical practitioners is a major component of cooperative patient care. Recently, mobile phones have been actively deployed in telemedicine applications. The mobile phone is an ideal medium to achieve faster delivery of reports to the referring medical practitioners. In this study, we developed an electronic medical report delivery system from a medical imaging department to the mobile phones of the referring doctors. The system extracts a text summary of medical report and a screen capture of diagnostic medical image in JPEG format, which are transmitted to 3G GSM mobile phones.

  1. Using A Model-Based Systems Engineering Approach For Exploration Medical System Development

    Science.gov (United States)

    Hanson, A.; Mindock, J.; McGuire, K.; Reilly, J.; Cerro, J.; Othon, W.; Rubin, D.; Urbina, M.; Canga, M.

    2017-01-01

    NASA's Human Research Program's Exploration Medical Capabilities (ExMC) element is defining the medical system needs for exploration class missions. ExMC's Systems Engineering (SE) team will play a critical role in successful design and implementation of the medical system into exploration vehicles. The team's mission is to "Define, develop, validate, and manage the technical system design needed to implement exploration medical capabilities for Mars and test the design in a progression of proving grounds." Development of the medical system is being conducted in parallel with exploration mission architecture and vehicle design development. Successful implementation of the medical system in this environment will require a robust systems engineering approach to enable technical communication across communities to create a common mental model of the emergent engineering and medical systems. Model-Based Systems Engineering (MBSE) improves shared understanding of system needs and constraints between stakeholders and offers a common language for analysis. The ExMC SE team is using MBSE techniques to define operational needs, decompose requirements and architecture, and identify medical capabilities needed to support human exploration. Systems Modeling Language (SysML) is the specific language the SE team is utilizing, within an MBSE approach, to model the medical system functional needs, requirements, and architecture. Modeling methods are being developed through the practice of MBSE within the team, and tools are being selected to support meta-data exchange as integration points to other system models are identified. Use of MBSE is supporting the development of relationships across disciplines and NASA Centers to build trust and enable teamwork, enhance visibility of team goals, foster a culture of unbiased learning and serving, and be responsive to customer needs. The MBSE approach to medical system design offers a paradigm shift toward greater integration between

  2. Recovery Audit Contractor medical necessity readiness: one health system's journey.

    Science.gov (United States)

    Scott, Judith A; Camden, Mindy

    2011-01-01

    To develop a sustainable approach to Recovery Audit Contractor medical necessity readiness that mitigates the regulatory and financial risks of the organization. Acute care hospitals. Utilizing the model for improvement and plan-do-study-act methodology, this health system designed and implemented a medical necessity case management program. We focused on 3 areas for improvement: medical necessity review accuracy, review timeliness, and physician adviser participation for secondary reviews. Over several months, we improved accuracy and timeliness of our medical necessity reviews while also generating additional inpatient revenue for the health system. We successfully enhanced regulatory compliance and reduced our financial risks associated with Recovery Audit Contractor medical necessity audits. A successful medical necessity case management program can not only enhance regulatory compliance and reduce the amount of payments recouped by Medicare, but also generate additional inpatient revenue for your organization. With health care reform and accountable care organizations on the horizon, hospitals must find ways to protect and enhance revenue in order to carry out their missions. This is one way for case managers to help in that cause, to advocate for the care of their patients, and to bring value to the organization.

  3. QUANTITATIVE СHARACTERISTICS OF COMPLEMENTARY INTEGRATED HEALTH CARE SYSTEM AND INTEGRATED MEDICATION MANAGEMENT INFORMATION SYSTEM

    Directory of Open Access Journals (Sweden)

    L. Yu. Babintseva

    2015-05-01

    i mportant elements of state regulation of the pharmaceutical sector health. For the first time creation of two information systems: integrated medication management infor mation system and integrated health care system in an integrated medical infor mation area, operating based on th e principle of complementarity was justified. Global and technological coefficients of these systems’ functioning were introduced.

  4. [The development of hospital medical supplies information management system].

    Science.gov (United States)

    Cao, Shaoping; Gu, Hongqing; Zhang, Peng; Wang, Qiang

    2010-05-01

    The information management of medical materials by using high-tech computer, in order to improve the efficiency of the consumption of medical supplies, hospital supplies and develop a new technology way to manage the hospital and material support. Using C # NET, JAVA techniques to develop procedures for the establishment of hospital material management information system, set the various management modules, production of various statistical reports, standard operating procedures. The system is convenient, functional and strong, fluent statistical functions. It can always fully grasp and understand the whole hospital supplies run dynamic information, as a modern and effective tool for hospital materials management.

  5. Recognition of medical errors' reporting system dimensions in educational hospitals.

    Science.gov (United States)

    Yarmohammadian, Mohammad H; Mohammadinia, Leila; Tavakoli, Nahid; Ghalriz, Parvin; Haghshenas, Abbas

    2014-01-01

    Nowadays medical errors are one of the serious issues in the health-care system and carry to account of the patient's safety threat. The most important step for achieving safety promotion is identifying errors and their causes in order to recognize, correct and omit them. Concerning about repeating medical errors and harms, which were received via theses errors concluded to designing and establishing medical error reporting systems for hospitals and centers that are presenting therapeutic services. The aim of this study is the recognition of medical errors' reporting system dimensions in educational hospitals. This research is a descriptive-analytical and qualities' study, which has been carried out in Shahid Beheshti educational therapeutic center in Isfahan during 2012. In this study, relevant information was collected through 15 face to face interviews. That each of interviews take place in about 1hr and creation of five focused discussion groups through 45 min for each section, they were composed of Metron, educational supervisor, health officer, health education, and all of the head nurses. Concluded data interviews and discussion sessions were coded, then achieved results were extracted in the presence of clear-sighted persons and after their feedback perception, they were categorized. In order to make sure of information correctness, tables were presented to the research's interviewers and final the corrections were confirmed based on their view. The extracted information from interviews and discussion groups have been divided into nine main categories after content analyzing and subject coding and their subsets have been completely expressed. Achieved dimensions are composed of nine domains of medical error concept, error cases according to nurses' prospection, medical error reporting barriers, employees' motivational factors for error reporting, purposes of medical error reporting system, error reporting's challenges and opportunities, a desired system

  6. The State of Emergency Medical Services (EMS) Systems in Africa.

    Science.gov (United States)

    Mould-Millman, Nee-Kofi; Dixon, Julia M; Sefa, Nana; Yancey, Arthur; Hollong, Bonaventure G; Hagahmed, Mohamed; Ginde, Adit A; Wallis, Lee A

    2017-06-01

    Introduction Little is known about the existence, distribution, and characteristics of Emergency Medical Services (EMS) systems in Africa, or the corresponding epidemiology of prehospital illness and injury. A survey was conducted between 2013 and 2014 by distributing a detailed EMS system questionnaire to experts in paper and electronic versions. The questionnaire ascertained EMS systems' jurisdiction, operations, finance, clinical care, resources, and regulatory environment. The discovery of respondents with requisite expertise occurred in multiple phases, including snowball sampling, a review of published scientific literature, and a rigorous search of the Internet. The survey response rate was 46%, and data represented 49 of 54 (91%) African countries. Twenty-five EMS systems were identified and distributed among 16 countries (30% of African countries). There was no evidence of EMS systems in 33 (61%) countries. A total of 98,574,731 (8.7%) of the African population were serviced by at least one EMS system in 2012. The leading causes of EMS transport were (in order of decreasing frequency): injury, obstetric, respiratory, cardiovascular, and gastrointestinal complaints. Nineteen percent of African countries had government-financed EMS systems and 26% had a toll-free public access telephone number. Basic emergency medical technicians (EMTs) and Basic Life Support (BLS)-equipped ambulances were the most common cadre of provider and ambulance level, respectively (84% each). Emergency Medical Services systems exist in one-third of African countries. Injury and obstetric complaints are the leading African prehospital conditions. Only a minority (<9.0%) of Africans have coverage by an EMS system. Most systems were predominantly BLS, government operated, and fee-for-service. Mould-Millman NK , Dixon JM , Sefa N , Yancey A , Hollong BG , Hagahmed M , Ginde AA , Wallis LA . The state of Emergency Medical Services (EMS) systems in Africa. Prehosp Disaster Med. 2017;32(3):273-283.

  7. Influence of magnetic field, chemical pressure and hydrostatic pressure on the structural and magnetocaloric properties of the Mn-Ni-Ge system

    Science.gov (United States)

    Taubel, Andreas; Gottschall, Tino; Fries, Maximilian; Faske, Tom; Skokov, Konstantin P.; Gutfleisch, Oliver

    2017-11-01

    The magnetic, structural and thermomagnetic properties of the MM’X material system of MnNiGe are evaluated with respect to their utilization in magnetocaloric refrigeration. The effects of separate and simultaneous substitution of Fe for Mn and Si on the Ge site are analysed in detail to highlight the benefits of the isostructural alloying method. A large range of compounds with precisely tunable structural and magnetic properties and the tuning of the phase transition by chemical pressure are compared to the effect of hydrostatic pressure on the martensitic transition. We obtained very large isothermal entropy changes Δ S_iso of up to -37.8 J kg-1 K-1 based on magnetic measurements for (Mn,Fe)NiGe in moderate fields of 2 T. The enhanced magnetocaloric properties for transitions around room temperature are demonstrated for samples with reduced Ge, a resource critical element. An adiabatic temperature change of 1.3 K in a magnetic field change of 1.93 T is observed upon direct measurement for a sample with Fe and Si substitution. However, the high volume change of 2.8% results in an embrittlement of large particles into several smaller fragments and leads to a sensitivity of the magnetocaloric properties towards sample shape and size. On the other hand, this large volume change enables to induce the phase transition with a large shift of the transition temperature by application of hydrostatic pressure (72 K GPa-1 ). Thus, the effect of 1.88 GPa is equivalent to a substitution of 10% Fe for Mn and can act as an additional stimulus to induce the phase transition and support the low magnetic field dependence of the phase transition temperature for multicaloric applications.

  8. System dynamics in medical education: a tool for life.

    Science.gov (United States)

    Rubin, David M; Richards, Christopher L; Keene, Penelope A C; Paiker, Janice E; Gray, A Rosemary T; Herron, Robyn F R; Russell, Megan J; Wigdorowitz, Brian

    2012-05-01

    A course in system dynamics has been included in the first year of our university's six-year medical curriculum. System Dynamics is a discipline that facilitates the modelling, simulation and analysis of a wide range of problems in terms of two fundamental concepts viz. rates and levels. Many topics encountered in the medical school curriculum, from biochemistry to sociology, can be understood in this way. The course was introduced following a curriculum review process in which it was concluded that knowledge of systems would serve to enhance problem-solving skills and clinical reasoning. The specific characteristics of system dynamics, the widespread use of digital computers, and the availability of suitable software made it possible to introduce the course at this level. The syllabus comprises a brief review of relevant mathematics followed by system dynamics topics taught in the context of examples, which are primarily but not exclusively medical. It is anticipated that this will introduce new thought processes to medical students, including holistic thinking and improved graphical visualisation skills.

  9. Ion conductivity and phase transitions in the Na3Sc2(PO4)3 - NaGe2(PO4)3 system

    International Nuclear Information System (INIS)

    Nogaj, A.S.

    2002-01-01

    Influence of heteropolyvalent substitution on dipole ordering of sodium-scandium phosphate, as well as on ion conductivity and phase transitions in the system Na 3 Sc 2 (PO 4 ) 3 - NaGe 2 (PO 4 ) 3 , was studied using the methods of solid phase synthesis, X-ray diffraction, laser spectroscopy and measurement of electric conductivity. Boundaries of the dipole-ordered and superionic phases existence ranges in the given system were identified. It is shown that expansion of the dipole-ordered phase existence range with increase in substituent cation concentration is characteristic of the phase on the basis of α-Na 3 Sc 2 (PO 4 ) 3 [ru

  10. Physical characteristics modification of a SiGe-HBT semiconductor device for performance improvement in a terahertz detecting system

    Science.gov (United States)

    Ghodsi, Hamed; Kaatuzian, Hassan

    2015-05-01

    In order to improve the performance of a pre-designed direct conversion terahertz detector which is implemented in a 0.25 μm-SiGe-BiCMOS process, we propose some slight modifications in the bipolar section of the SiGe device physical design. Comparison of our new proposed device and the previously reported device is done by SILVACO TCAD software simulation and we have used previous experimentally reported data to confirm our software simulations. Our proposed modifications in device structural design show a present device responsivity improvement of about 10% from 1 to 1.1 A/W while the bandwidth improvement is about 218 GHz. The minimum noise equivalent power at detector output is increased by about 14.3% and finally power consumption per pixel at the maximum responsivity is decreased by about 5%.

  11. Physical characteristics modification of a SiGe-HBT semiconductor device for performance improvement in a terahertz detecting system

    International Nuclear Information System (INIS)

    Ghodsi, Hamed; Kaatuzian, Hassan

    2015-01-01

    In order to improve the performance of a pre-designed direct conversion terahertz detector which is implemented in a 0.25 μm-SiGe-BiCMOS process, we propose some slight modifications in the bipolar section of the SiGe device physical design. Comparison of our new proposed device and the previously reported device is done by SILVACO TCAD software simulation and we have used previous experimentally reported data to confirm our software simulations. Our proposed modifications in device structural design show a present device responsivity improvement of about 10% from 1 to 1.1 A/W while the bandwidth improvement is about 218 GHz. The minimum noise equivalent power at detector output is increased by about 14.3% and finally power consumption per pixel at the maximum responsivity is decreased by about 5%. (paper)

  12. Growth and characterization of isotopically enriched 70Ge and 74Ge single crystals

    International Nuclear Information System (INIS)

    Itoh, K.

    1992-10-01

    Isotopically enriched 70 Ge and 74 Ge single crystals were successfully gown by a newly developed vertical Bridgman method. The system allows us to reliably grow high purity Ge single crystals of approximately 1 cm 3 volume. To our knowledge, we have grown the first 70 Ge single crystal. The electrically active chemical impurity concentration for both crystals was found to be ∼2 x cm -3 which is two order of magnitude better that of 74 Ge crystals previously grown by two different groups. Isotopic enrichment of the 70 Ge and the 74 Ge crystals is 96.3% and 96.8%, respectively. The residual chemical impurities present in both crystals were identified as phosphorus, copper, aluminum, and indium. A wide variety of experiments which take advantage of the isotopic purity of our crystals are discussed

  13. EM-GE-5 Regulation. Standard for the first-rate application clinical practices in the execution of the clinical investigations for medical teams' evaluation

    International Nuclear Information System (INIS)

    2015-01-01

    This guide has the following objectives: a) To guide methodologically the implementation of Good Clinical Practice for the execution of clinical research with medical devices that need to be evaluated, in addition to the Regulation E R-6. Requirements for the Conduct of Clinical Trials for Medical Devices , b) Provide the fundamental aspects to be taken into count for quality control to clinical investigations.

  14. Choosing a New Telephone System for Your Medical Practice.

    Science.gov (United States)

    Metherell, Brian

    2016-01-01

    E-mail may rule the world in other types of businesses, but for medical practices, the telephone remains the primary mode of communication with patients, specialists, and pharmacies. From making appointments to calling in prescriptions, telephones are essential to patient care. With technology changing very quickly and new capabilities coming into the medical practice, such as telemedicine and Skype, you need to know your options when choosing a new telephone system. The possibilities include on-site, cloud, and hybrid networked solutions. A wide variety of features and capabilities are available, from dozens of vendors. Of course, no matter what telephone solution you choose, you must meet regulatory compliance, particularly HIPAA, and Payment Card Industry Data Security Standard if you take credit cards. And it has to be affordable, reliable, and long lasting. This article explores what medical practices need to know when choosing a new business telephone system in order to find the right solutions for their businesses.

  15. VXIbus-based signal generator for resonant power supply system of the 3 GeV RCS

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Fengqing; Watanabe, Yasuhiro; Koseki, Shoichiro; Tani, Norio [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Adachi, Toshikazu; Someya, Hirohiko [High Energy Accelerator Reseach Organization, Tsukuba, Ibaraki (Japan)

    2002-03-01

    The 3 GeV Proton RCS of the JAERI-KEK Joint Project is a 25 Hz separate-function rapid cycling synchrotron under design. Bending magnets (BM) and quadrupole magnets (QM) are excited separately. The 3 GeV RCS requests above 10 families of magnets excited independently, far beyond 3 families in practical RCS's. Difficulty of field tracking between BM and QM is significantly increased. Magnet strings are grouped into resonant networks and excited resonantly with power supplies driven by a waveform pattern, typically a DC-biased sinusoidal signal. To achieve a close tracking between many families, the driving signal of each power supply should be adjusted in phase and amplitude flexibly and dynamically. This report proposes a signal generator based on VXIbus. The VXIbus, an extension of VMEbus (VME eXtensions for Instrument), provides an open architecture with shared process bus and timing. The VXIbus-based signal generator facilitates the timing synchronization and is easy to extend to many channels needed by the 3 GeV RCS. Experimental results of the signal generator are reported. (author)

  16. Why decision support systems are important for medical education.

    Science.gov (United States)

    Konstantinidis, Stathis Th; Bamidis, Panagiotis D

    2016-03-01

    During the last decades, the inclusion of digital tools in health education has rapidly lead to a continuously enlarging digital era. All the online interactions between learners and tutors, the description, creation, reuse and sharing of educational digital resources and the interlinkage between them in conjunction with cheap storage technology has led to an enormous amount of educational data. Medical education is a unique type of education due to accuracy of information needed, continuous changing competences required and alternative methods of education used. Nowadays medical education standards provide the ground for organising the educational data and the paradata. Analysis of such education data through education data mining techniques is in its infancy, but decision support systems (DSSs) for medical education need further research. To the best of our knowledge, there is a gap and a clear need for identifying the challenges for DSSs in medical education in the era of medical education standards. Thus, in this Letter the role and the attributes of such a DSS for medical education are delineated and the challenges and vision for future actions are identified.

  17. Modifying the Medical Research Council grading system through Rasch analyses

    NARCIS (Netherlands)

    Vanhoutte, Els Karla; Faber, Catharina Gerritdina; van Nes, Sonja Ingrid; Jacobs, Bart Casper; van Doorn, Pieter Antoon; van Koningsveld, Rinske; Cornblath, David Reid; van der Kooi, Anneke Jelly; Cats, Elisabeth Aviva; van den Berg, Leonard Hendrik; Notermans, Nicolette Claudia; van der Pol, Willem Lodewijk; Hermans, Mieke Catharina Elisabeth; van der Beek, Nadine Anna Maria Elisabeth; Gorson, Kenneth Craig; Eurelings, Marijke; Engelsman, Jeroen; Boot, Hendrik; Meijer, Ronaldus Jacobus; Lauria, Giuseppe; Tennant, Alan; Merkies, Ingemar Sergio José; Barreira, A. A.; Bennett, D.; van den Bergh, P. Y. K.; Bril, V.; Devigili, G.; Hadden, R. D.; Hahn, A. F.; Hartung, H.-P.; Hughes, R. A. C.; Illa, I.; Katzberg, H.; Léger, J.-M.; Lewis, R. A.; Lunn, M. P. T.; Nascimento, O. J. M.; Nobile-Orazio, E.; Padua, L.; Pouget, J.; Reilly, M. M.; van Schaik, I.; Smith, B.; de Visser, M.; Walk, D.

    2012-01-01

    The Medical Research Council grading system has served through decades for the evaluation of muscle strength and has been recognized as a cardinal feature of daily neurological, rehabilitation and general medicine examination of patients, despite being respectfully criticized due to the unequal

  18. Modifying the Medical Research Council grading system through Rasch analyses

    NARCIS (Netherlands)

    E.K. Vanhoutte (Els); C.G. Faber (Carin); S.I. van Nes (Sonja); B.C. Jacobs (Bart); P.A. van Doorn (Pieter); R. van Koningsveld (Rinske); D.R. Cornblath (David); A.J. Kooj (Anneke); E.A. Cats (Elisabeth); L.H. van den Berg (Leonard); N.C. Notermans (Nicolette); W.L. van der Pol (Ludo); M.C.E. Hermans; N.A.M.E. van der Beek (Nadine); K.C. Gorson (Kenneth); M. Eurelings (Marijke); L. Engelsman (Lyda); H. Boot (Hendrik); R.J. Meijer (Ron); G. Lauria (Giuseppe); C. Tennant (Christopher); I.S.J. Merkies (Ingemar)

    2012-01-01

    textabstractThe Medical Research Council grading system has served through decades for the evaluation of muscle strength and has been recognized as a cardinal feature of daily neurological, rehabilitation and general medicine examination of patients, despite being respectfully criticized due to the

  19. Radio compatibility studies for medical body area network systems

    NARCIS (Netherlands)

    Chrysallos, E.

    2013-01-01

    Evolution in healthcare during the last two decades has had tremendous impact on people's lives, extending life expectancy and improving patient care. One of the reasons this happened is the introduction of Medical Body Area Network Systems (MBANSs), a technology enabling the measurement and

  20. Systemic ototoxicity: a review | Shine | East African Medical Journal

    African Journals Online (AJOL)

    Objectives: To review the literature pertaining to the ototoxic potential of three frequently prescribed systemic medications in the sub-Saharan setting; quinine, furosemide and aminoglycoside antibiotics. The pathophysiology, clinical manifestations and risk factors and risk minimisation strategies regarding the ototoxicity ...

  1. Management information system of medical equipment using mobile devices

    Science.gov (United States)

    Núñez, C.; Castro, D.

    2011-09-01

    The large numbers of technologies currently incorporated into mobile devices transform them into excellent tools for capture and to manage the information, because of the increasing computing power and storage that allow to add many miscellaneous applications. In order to obtain benefits of these technologies, in the biomedical engineering field, it was developed a mobile information system for medical equipment management. The central platform for the system it's a mobile phone, which by a connection with a web server, it's capable to send and receive information relative to any medical equipment. Decoding a type of barcodes, known as QR-Codes, the management process is simplified and improved. These barcodes identified the medical equipments in a database, when these codes are photographed and decoded with the mobile device, you can access to relevant information about the medical equipment in question. This Project in it's actual state is a basic support tool for the maintenance of medical equipment. It is also a modern alternative, competitive and economic in the actual market.

  2. A Total Information Management System For All Medical Images

    Science.gov (United States)

    Ouimette, Donald; Nudelman, Sol; Ramsby, Gale; Spackman, Thomas

    1985-09-01

    A PACS has been designed for the University of Connecticut Health Center to serve all departments acquiring images for diagnosis, surgery and therapy. It incorporates a multiple community communications architecture to provide complete information management for medical images, medical data and departmental administrative matter. The system is modular and expandable. It permits an initial installation for radiology and subsequent expansion to include other departments at the Health Center, beginning with internal medicine, surgery, ophthalmology and dentistry. The design permits sufficient expansion to offer the potential for accepting the additional burden of a hospital information system. Primary parameters that led to this system design were based on the anticipation that departments in time could achieve generating 60 to 90% of their images suited to insertion in a PACS, that a high network throughput for large block image transfers would be essen-tial and that total system reliability was fundamental to success.

  3. Clinical information system based on the medical smart card.

    Science.gov (United States)

    Danon, Y L; Saiag, E

    2000-07-01

    Over the last 5 years Israel has implemented a nationwide health insurance plan covering the entire population of the country. We have developed a clinical information system based on electronic-chip health care medical smart cards. Health care cards are used in several European countries and chip smart cards have been successful in many sectors. Our project involves the community use of the MSC, thereby enabling health care professionals to skillfully employ card systems in the health care sector. This system can easily arrange electronic medical charts in clinics, facilitating the confidential sharing of personal health databases among health professionals. To develop an MSC applicable for daily use in the community and hospital system. The MSC project, currently underway in Israel and the USA, will aid in determining the costs, benefits and feasibility of the MSC. Successful implementation of the MSC in chosen clinics will promote a nationwide willingness to adopt this promising technology.

  4. Studies of adsorber materials for preparing 68Ge/68Ga generators

    International Nuclear Information System (INIS)

    Brambilla, Tania de Paula

    2013-01-01

    The 68 Ga is a promising radionuclide for nuclear medicine, decaying by positron emission with an abundance of 89%, with physical half-life of 68 minutes, which is compatible with the pharmacokinetics of many biomolecules and low molecular weight substrates. Another important feature is its availability through a generator system, where the parent radionuclide, 68 Ge (t 1/2 = 270.95 days) is adsorbed on a column and the daughter, 68 Ga, is eluted in an ionic form 68Ga 3+ . The development of 68 Ge/ 68 Ga generators began in the 60s, but its clinical use began to be acceptable and relevant only recently. The method of separation of 68 Ge and 68 Ga most used is the ion-exchange chromatographic system, due to its practical operation, but other generator systems have been proposed, such as solvent extraction and evaporation technique. Currently, 68 Ge/ 68 Ga generators are commercially available using inorganic matrices columns prepared with TiO 2 or SnO 2 as well using organic resin. The efficiency of 68 Ga elution ranges from 70% to 80%, decreasing over time. The 68 Ge breakthrough varies from 10 -2 to10 -3 % or lower in a fresh generator, but there is an increase in the levels of contamination after long periods of use. Even with all the technological advances in the development of 68 Ge/ 68 Ga generators in the past decades, the 68 Ga eluted from commercial generators is not suitable for direct use in humans and some improvements in the systems need to be made to reduce the 68 Ge breakthrough and chemical impurities levels. The main objective of this work was to develop a 68 Ge/ 68 Ga generator system is which 68 Ga could be eluted with quality required for clinical use. The chemical behavior of Ge and Ga was evaluated on various inorganic adsorbents materials. Two types of 68 Ge/ 68 Ga generator systems were developed using TiO 2 as adsorbent material: elution system with manual pressure and vacuum controlled. The efficiencies of the generators were similar to

  5. Expression of variable viruses as herpes simplex glycoprotein D and varicella zoster gE glycoprotein using a novel plasmid based expression system in insect cell

    Directory of Open Access Journals (Sweden)

    A.M. Al-Sulaiman

    2017-11-01

    Full Text Available Several prokaryotic and eukaryotic expression systems have been used for in vitro production of viruses’ proteins. However eukaryotic expression system was always the first choice for production of proteins that undergo post-translational modification such as glycosylation. Recombinant baculoviruses have been widely used as safe vectors to express heterologous genes in the culture of insect cells, but the manipulation involved in creating, titrating, and amplifying viral stocks make it time consuming and laborious. Therefore, to facilitate rapid expression in insect cell, a plasmid based expression system was used to express herpes simplex type 1 glycoprotein D (HSV-1 gD and varicella zoster glycoprotein E (VZV gE. Recombinant plasmids were generated, transfected into insect cells (SF9, and both glycoproteins were expressed 48 h post-infection. A protein with approximately molecular weight of 64-kDa and 98-kDa for HSV-1 gD and VZV gE respectively was expressed and confirmed by SDS. Proteins were detected in insect cells cytoplasm and outer membrane by immunofluorescence. The antigenicity and immunoreactivity of each protein were confirmed by immunoblot and ELISA. Results suggest that this system can be an alternative to the traditional baculovirus expression for small scale expression system in insect cells.

  6. Language of Czech Medical Reports and Classification Systems in Medicine

    Czech Academy of Sciences Publication Activity Database

    Přečková, Petra

    2010-01-01

    Roč. 6, č. 1 (2010), s. 58-65 ISSN 1801-5603 R&D Projects: GA MŠk(CZ) 1M06014 Institutional research plan: CEZ:AV0Z10300504 Keywords : terminology, * synonyms * classification systems * thesaurus * nomenclature * electronic health record * interoperability * semantic interoperability * cardiology * atherosclerosis Subject RIV: IN - Informatics, Computer Science http://www.ejbi.org/en/ejbi/article/53-en-language-of-czech-medical-reports- and -classification-systems-in-medicine.html

  7. An intelligent medical system for diagnosis of bone diseases

    International Nuclear Information System (INIS)

    Hatzilygeroudis, I.; Vassilakos, P.J.; Tsakalidis, A.

    1994-01-01

    In this paper, aspects of the design of an intelligent medical system for diagnosis of bone diseases that can be detected by scintigraphic images are presented. The system comprises three major parts: a user interface (UI), a database management system (DBMS), and an expert system (ES). The DBMS is used for manipulation of various patient data. A number of patient cases are selected as prototype and stored in separate database. Diagnosis is performed via the ES, called XBONE, based on patient data. Knowledge is represented via an integrated formalism that combines production rules and a neural network. This results in better representation, and facilitates knowledge acquisition and maintenance. (authors)

  8. An intelligent medical system for diagnosis of bone diseases

    Energy Technology Data Exchange (ETDEWEB)

    Hatzilygeroudis, I [University of Patras, School of Engineering, Department of Computer Engineering and Informatics, 26500 Patras, Greece (Greece); Vassilakos, P J [Regional University Hospital of Patras, Department of Nuclear Medicine, Patras Greece (Greece); Tsakalidis, A [Computer Technology Institute, P.O. Box 1122, 26110 Patras, Greece (Greece)

    1994-12-31

    In this paper, aspects of the design of an intelligent medical system for diagnosis of bone diseases that can be detected by scintigraphic images are presented. The system comprises three major parts: a user interface (UI), a database management system (DBMS), and an expert system (ES). The DBMS is used for manipulation of various patient data. A number of patient cases are selected as prototype and stored in separate database. Diagnosis is performed via the ES, called XBONE, based on patient data. Knowledge is represented via an integrated formalism that combines production rules and a neural network. This results in better representation, and facilitates knowledge acquisition and maintenance. (authors). 10 refs., 2 figs.

  9. Evaluating the success of an emergency response medical information system.

    Science.gov (United States)

    Petter, Stacie; Fruhling, Ann

    2011-07-01

    STATPack™ is an information system used to aid in the diagnosis of pathogens in hospitals and state public health laboratories. STATPack™ is used as a communication and telemedicine diagnosis tool during emergencies. This paper explores the success of this emergency response medical information system (ERMIS) using a well-known framework of information systems success developed by DeLone and McLean. Using an online survey, the entire population of STATPack™ users evaluated the success of the information system by considering system quality, information quality, system use, intention to use, user satisfaction, individual impact, and organizational impact. The results indicate that the overall quality of this ERMIS (i.e., system quality, information quality, and service quality) has a positive impact on both user satisfaction and intention to use the system. However, given the nature of ERMIS, overall quality does not necessarily predict use of the system. Moreover, the user's satisfaction with the information system positively affected the intention to use the system. User satisfaction, intention to use, and system use had a positive influence on the system's impact on the individual. Finally, the organizational impacts of the system were positively influenced by use of the system and the system's individual impact on the user. The results of the study demonstrate how to evaluate the success of an ERMIS as well as introduce potential changes in how one applies the DeLone and McLean success model in an emergency response medical information system context. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  10. Integrated software system for improving medical equipment management.

    Science.gov (United States)

    Bliznakov, Z; Pappous, G; Bliznakova, K; Pallikarakis, N

    2003-01-01

    The evolution of biomedical technology has led to an extraordinary use of medical devices in health care delivery. During the last decade, clinical engineering departments (CEDs) turned toward computerization and application of specific software systems for medical equipment management in order to improve their services and monitor outcomes. Recently, much emphasis has been given to patient safety. Through its Medical Device Directives, the European Union has required all member nations to use a vigilance system to prevent the reoccurrence of adverse events that could lead to injuries or death of patients or personnel as a result of equipment malfunction or improper use. The World Health Organization also has made this issue a high priority and has prepared a number of actions and recommendations. In the present workplace, a new integrated, Windows-oriented system is proposed, addressing all tasks of CEDs but also offering a global approach to their management needs, including vigilance. The system architecture is based on a star model, consisting of a central core module and peripheral units. Its development has been based on the integration of 3 software modules, each one addressing specific predefined tasks. The main features of this system include equipment acquisition and replacement management, inventory archiving and monitoring, follow up on scheduled maintenance, corrective maintenance, user training, data analysis, and reports. It also incorporates vigilance monitoring and information exchange for adverse events, together with a specific application for quality-control procedures. The system offers clinical engineers the ability to monitor and evaluate the quality and cost-effectiveness of the service provided by means of quality and cost indicators. Particular emphasis has been placed on the use of harmonized standards with regard to medical device nomenclature and classification. The system's practical applications have been demonstrated through a pilot

  11. Discovery of a Red-Emitting Li3RbGe8O18:Mn4+ Phosphor in the Alkali-Germanate System: Structural Determination and Electronic Calculations.

    Science.gov (United States)

    Singh, Satendra Pal; Kim, Minseuk; Park, Woon Bae; Lee, Jin-Woong; Sohn, Kee-Sun

    2016-10-17

    A solid-state combinatorial chemistry approach, which used the A-Ge-O (A = Li, K, Rb) system doped with a small amount of Mn 4+ as an activator, was adopted in a search for novel red-emitting phosphors. The A site may have been composed of either a single alkali metal ion or of a combination of them. This approach led to the discovery of a novel phosphor in the above system with the chemical formula Li 3 RbGe 8 O 18 :Mn 4+ . The crystal structure of this novel phosphor was solved via direct methods, and subsequent Rietveld refinement revealed a trigonal structure in the P3̅1m space group. The discovered phosphor is believed to be novel in the sense that neither the crystal structure nor the chemical formula matches any of the prototype structures available in the crystallographic information database (ICDD or ICSD). The measured photoluminescence intensity that peaked at a wavelength of 667 nm was found to be much higher than the best intensity obtained among all the existing A 2 Ge 4 O 9 (A = Li, K, Rb) compounds in the alkali-germanate system. An ab initio calculation based on density function theory (DFT) was conducted to verify the crystal structure model and compare the calculated value of the optical band gap with the experimental results. The optical band gap obtained from diffuse reflectance measurement (5.26 eV) and DFT calculation (4.64 eV) results were in very good agreement. The emission wavelength of this phosphor that exists in the deep red region of the electromagnetic spectrum may be very useful for increasing the color gamut of LED-based display devices such as ultrahigh-definition television (UHDTV) as per the ITU-R BT.2020-2 recommendations and also for down-converter phosphors that are used in solar-cell applications.

  12. The Nigerian health care system: Need for integrating adequate medical intelligence and surveillance systems

    Directory of Open Access Journals (Sweden)

    Menizibeya Osain Welcome

    2011-01-01

    Full Text Available Objectives : As an important element of national security, public health not only functions to provide adequate and timely medical care but also track, monitor, and control disease outbreak. The Nigerian health care had suffered several infectious disease outbreaks year after year. Hence, there is need to tackle the problem. This study aims to review the state of the Nigerian health care system and to provide possible recommendations to the worsening state of health care in the country. To give up-to-date recommendations for the Nigerian health care system, this study also aims at reviewing the dynamics of health care in the United States, Britain, and Europe with regards to methods of medical intelligence/surveillance. Materials and Methods : Databases were searched for relevant literatures using the following keywords: Nigerian health care, Nigerian health care system, and Nigerian primary health care system. Additional keywords used in the search were as follows: United States (OR Europe health care dynamics, Medical Intelligence, Medical Intelligence systems, Public health surveillance systems, Nigerian medical intelligence, Nigerian surveillance systems, and Nigerian health information system. Literatures were searched in scientific databases Pubmed and African Journals OnLine. Internet searches were based on Google and Search Nigeria. Results : Medical intelligence and surveillance represent a very useful component in the health care system and control diseases outbreak, bioattack, etc. There is increasing role of automated-based medical intelligence and surveillance systems, in addition to the traditional manual pattern of document retrieval in advanced medical setting such as those in western and European countries. Conclusion : The Nigerian health care system is poorly developed. No adequate and functional surveillance systems are developed. To achieve success in health care in this modern era, a system well grounded in routine

  13. Image quality of medical X-ray systems

    International Nuclear Information System (INIS)

    Hoen, P.J. 't.

    1980-01-01

    The quality of images made by medical X-ray systems can only be properly described if the visual system is also taken into account. In this thesis, the visual threshold contrast of edges, bars and disks has been chosen as the criterion. Since these objects resemble medical objects like tumour-mass outlines, blood vessels and micro-calcifications, a correlation with X-ray practice is possible. Only the conventional X-ray systems are considered, but a brief analysis of computerized tomography is given. Considerable attention is paid to unsharpness and the minimization of its influence on the threshold contrast, to the influence of the noise on the threshold contrast, and to the contrast formation as such. The consequences for the dose administered to the patient are also briefly analysed. (Auth.)

  14. Observation of a peak at 1.28 GeV in the etaππ system in the reaction γp -> etaπ+π-p

    International Nuclear Information System (INIS)

    Atkinson, M.; Davenport, M.; Flower, P.; Hutton, J.S.; Kumar, B.R.; Morris, J.A.G.; Morris, J.V.; Sharp, P.H.; Lassalle, J.C.; Patrick, G.N.; Storr, K.M.; Axon, T.J.; Barberis, D.; Brodbeck, T.J.; Brookes, G.R.; Bunn, J.J.; Bussey, P.J.; Clegg, A.B.; Dainton, J.B.; Dickinson, B.; Diekmann, B.; Donnachie, A.; Ellison, R.J.; Flynn, P.J.; Galbraith, W.; Heinloth, K.; Henderson, R.C.W.; Hughes-Jones, R.E.; Ibbotson, M.; Jakob, H.P.; Jung, M.; Lafferty, G.D.; Lane, J.B.; Liebenau, V.; McClatchey, R.; Mercer, D.; Newton, D.; Paterson, C.; Paul, E.; Raine, C.; Reidenbach, M.; Rotscheidt, H.; Schloesser, A.; Skillicorn, I.O.; Smith, K.M.; Thompson, R.J.; Waite, A.P.; Worsell, M.F.

    1984-01-01

    A peak is reported in the etaπ + π - system, produced in the reaction γp->etaπ + π - p, at a mass of 1.28+-0.01 GeV with a width of 0.08+-0.02 GeV. Possible spin-parity assignments for the peak are shown to be Jsup(π)=1 - , Jsup(π)=1 + or Jsup(π)=2 + and interpretations of these assignments are discussed. (orig.)

  15. Two-processor automatized system to control fast measurements of the magnetic field index of the JINR 10 GeV proton synchrotron

    International Nuclear Information System (INIS)

    Chernykh, E.V.

    1981-01-01

    A two-processor system comprizing a hard-wired module and ES-1010 computer to control measurements of the magnetic field index of the JINR 10 GeV proton synchrotron is described. The system comprises the control module, a computer interface and a parallel branch driver residing in CAMAC system crate. The control module controls analogue multiplexer and analogue-to-digital converter through their front panels and writes down the information into a buffer memory module through the CAMAC highway. The computer controls the system, reads the information into core memory, writes down it on a magnetic tape, processes it and outputs n=f(r) plots on TV monitor and printer. The system provides the measurement up to 100 points during a magnetic field rise and minimal time of measurement 50 μs [ru

  16. DESIGN AND DEVELOPMENT OF A REMOTE MEDICAL CONSULTATION SYSTEM

    Directory of Open Access Journals (Sweden)

    "A. Delrobaee

    2006-05-01

    Full Text Available Telemedicine is an indispensable tool in the hands of doctors to accelerate and facilitate the process of data interchange. To publicize and distribute the culture of utilizing this technology and providing the necessary equipment for this purpose and also to commence some useful activities in this field of science in Iran, the researchers group have designed and performed a telemedicine internet site with the goal of medical consultation. Software was designed and prepared, which is accessible to three groups of users with definite level of access for each one: normal users, doctors and site administrators. There are four main forums on this website with the following titles: medical consultation (Q&A, doctors’ special forum, scientific and research centers and also special disease groups, and the forum of graduates and medical students. Ultimately, we could achieve a new horizon to expand telemedicine activities in the field of medical consultation. A free web-based system was developed through the address of www.teleteb.com with the aim of remote medical consultation, developing the public health services and creating a powerful scientific and research link in the society of medicine.

  17. Organizative structure of the System for Integral Management of Archive Documents (SiGeID 1.0)

    OpenAIRE

    Irima Campillo Torres; Raudel J. Rosquete Martínez; Magalys Palomino Palomino; Dominica Legañoa Ferrá; Anysley Cano Inclán; Idalmis Cabrera Morales

    2012-01-01

    El nuevo contexto impone a las organizaciones la necesidad vital de disponer de adecuadas infraestructuras de comunicación, que les permitan conseguir un conocimiento real y suficiente del entorno. El presente artículo pretende mostrar la estructura organizativa del Sistema de Gestión Integral de Documentos de archivo SiGeID (1.0), como una herramienta informática que ayuda a las organizaciones empresariales al perfeccionamiento de la gestión de documentos. Dividido en tres módulos: Gestión y...

  18. Medical telerobotic systems: current status and future trends.

    Science.gov (United States)

    Avgousti, Sotiris; Christoforou, Eftychios G; Panayides, Andreas S; Voskarides, Sotos; Novales, Cyril; Nouaille, Laurence; Pattichis, Constantinos S; Vieyres, Pierre

    2016-08-12

    Teleoperated medical robotic systems allow procedures such as surgeries, treatments, and diagnoses to be conducted across short or long distances while utilizing wired and/or wireless communication networks. This study presents a systematic review of the relevant literature between the years 2004 and 2015, focusing on medical teleoperated robotic systems which have witnessed tremendous growth over the examined period. A thorough insight of telerobotics systems discussing design concepts, enabling technologies (namely robotic manipulation, telecommunications, and vision systems), and potential applications in clinical practice is provided, while existing limitations and future trends are also highlighted. A representative paradigm of the short-distance case is the da Vinci Surgical System which is described in order to highlight relevant issues. The long-distance telerobotics concept is exemplified through a case study on diagnostic ultrasound scanning. Moreover, the present review provides a classification into short- and long-distance telerobotic systems, depending on the distance from which they are operated. Telerobotic systems are further categorized with respect to their application field. For the reviewed systems are also examined their engineering characteristics and the employed robotics technology. The current status of the field, its significance, the potential, as well as the challenges that lie ahead are thoroughly discussed.

  19. National electronic medical records integration on cloud computing system.

    Science.gov (United States)

    Mirza, Hebah; El-Masri, Samir

    2013-01-01

    Few Healthcare providers have an advanced level of Electronic Medical Record (EMR) adoption. Others have a low level and most have no EMR at all. Cloud computing technology is a new emerging technology that has been used in other industry and showed a great success. Despite the great features of Cloud computing, they haven't been utilized fairly yet in healthcare industry. This study presents an innovative Healthcare Cloud Computing system for Integrating Electronic Health Record (EHR). The proposed Cloud system applies the Cloud Computing technology on EHR system, to present a comprehensive EHR integrated environment.

  20. Molecules for materials: germanium hydride neutrals and anions. Molecular structures, electron affinities, and thermochemistry of GeHn/GeHn- (n = 0-4) and Ge2Hn/Ge2Hn(-) (n = 0-6).

    Science.gov (United States)

    Li, Qian-Shu; Lü, Rui-Hua; Xie, Yaoming; Schaefer, Henry F

    2002-12-01

    The GeH(n) (n = 0-4) and Ge(2)H(n) (n = 0-6) systems have been studied systematically by five different density functional methods. The basis sets employed are of double-zeta plus polarization quality with additional s- and p-type diffuse functions, labeled DZP++. For each compound plausible energetically low-lying structures were optimized. The methods used have been calibrated against a comprehensive tabulation of experimental electron affinities (Chemical Reviews 102, 231, 2002). The geometries predicted in this work include yet unknown anionic species, such as Ge(2)H(-), Ge(2)H(2)(-), Ge(2)H(3)(-), Ge(2)H(4)(-), and Ge(2)H(5)(-). In general, the BHLYP method predicts the geometries closest to the few available experimental structures. A number of structures rather different from the analogous well-characterized hydrocarbon radicals and anions are predicted. For example, a vinylidene-like GeGeH(2) (-) structure is the global minimum of Ge(2)H(2) (-). For neutral Ge(2)H(4), a methylcarbene-like HGë-GeH(3) is neally degenerate with the trans-bent H(2)Ge=GeH(2) structure. For the Ge(2)H(4) (-) anion, the methylcarbene-like system is the global minimum. The three different neutral-anion energy differences reported in this research are: the adiabatic electron affinity (EA(ad)), the vertical electron affinity (EA(vert)), and the vertical detachment energy (VDE). For this family of molecules the B3LYP method appears to predict the most reliable electron affinities. The adiabatic electron affinities after the ZPVE correction are predicted to be 2.02 (Ge(2)), 2.05 (Ge(2)H), 1.25 (Ge(2)H(2)), 2.09 (Ge(2)H(3)), 1.71 (Ge(2)H(4)), 2.17 (Ge(2)H(5)), and -0.02 (Ge(2)H(6)) eV. We also reported the dissociation energies for the GeH(n) (n = 1-4) and Ge(2)H(n) (n = 1-6) systems, as well as those for their anionic counterparts. Our theoretical predictions provide strong motivation for the further experimental study of these important germanium hydrides. Copyright 2002 Wiley

  1. Situating Remediation: Accommodating Success and Failure in Medical Education Systems.

    Science.gov (United States)

    Ellaway, Rachel H; Chou, Calvin L; Kalet, Adina L

    2018-03-01

    There has been a widespread shift to competency-based medical education (CBME) in the United States and Canada. Much of the CBME discourse has focused on the successful learner, with relatively little attention paid to what happens in CBME systems when learners stumble or fail. Emerging issues, such as the well-documented problem of "failure to fail" and concerns about litigious learners, have highlighted a need for well-defined and integrated frameworks to support and guide strategic approaches to the remediation of struggling medical learners.This Perspective sets out a conceptual review of current practices and an argument for a holistic approach to remediation in the context of their parent medical education systems. The authors propose parameters for integrating remediation into CBME and describe a model based on five zones of practice along with the rules of engagement associated with each zone. The zones are "normal" curriculum, corrective action, remediation, probation, and exclusion.The authors argue that, by linking and integrating theory and practice in remediation with CBME, a more integrated systems-level response to differing degrees of learner difficulty and failure can be developed. The proposed model demonstrates how educational practice in different zones is based on different rules, roles, responsibilities, and thresholds for moving between zones. A model such as this can help medical educators and medical education leaders take a more integrated approach to learners' failures as well as their successes by being more explicit about the rules of engagement that apply in different circumstances across the competency continuum.

  2. 5 CFR 293.504 - Composition of, and access to, the Employee Medical File System.

    Science.gov (United States)

    2010-01-01

    ... Employee Medical File System. 293.504 Section 293.504 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PERSONNEL RECORDS Employee Medical File System Records § 293.504 Composition of, and access to, the Employee Medical File System. (a) All employee occupational medical records...

  3. Real-Time Implementation of Medical Ultrasound Strain Imaging System

    International Nuclear Information System (INIS)

    Jeong, Mok Kun; Kwon, Sung Jae; Bae, Moo Ho

    2008-01-01

    Strain imaging in a medical ultrasound imaging system can differentiate the cancer or tumor in a lesion that is stiffer than the surrounding tissue. In this paper, a strain imaging technique using quasistatic compression is implemented that estimates the displacement between pre- and postcompression ultrasound echoes and obtains strain by differentiating it in the spatial direction. Displacements are computed from the phase difference of complex baseband signals obtained using their autocorrelation, and errors associated with converting the phase difference into time or distance are compensated for by taking into the center frequency variation. Also, to reduce the effect of operator's hand motion, the displacements of all scanlines are normalized with the result that satisfactory strain image quality has been obtained. These techniques have been incorporated into implementing a medical ultrasound strain imaging system that operates in real time.

  4. Medical record management systems: criticisms and new perspectives.

    Science.gov (United States)

    Frénot, S; Laforest, F

    1999-06-01

    The first generation of computerized medical records stored the data as text, but these records did not bring any improvement in information manipulation. The use of a relational database management system (DBMS) has largely solved this problem as it allows for data requests by using SQL. However, this requires data structuring which is not very appropriate to medicine. Moreover, the use of templates and icon user interfaces has introduced a deviation from the paper-based record (still existing). The arrival of hypertext user interfaces has proven to be of interest to fill the gap between the paper-based medical record and its electronic version. We think that further improvement can be accomplished by using a fully document-based system. We present the architecture, advantages and disadvantages of classical DBMS-based and Web/DBMS-based solutions. We also present a document-based solution and explain its advantages, which include communication, security, flexibility and genericity.

  5. A Distributed and Collaborative Intelligent System for Medical Diagnosis

    Directory of Open Access Journals (Sweden)

    Wided LEJOUAD-CHAARI

    2013-08-01

    Full Text Available In this paper, we present a distributed collaborative system assisting physicians in diagnosis when processing medical images. This is a Web-based solution since the different participants and resources are on various sites. It is collaborative because these participants (physicians, radiologists, knowledgebasesdesigners, program developers for medical image processing, etc. can work collaboratively to enhance the quality of programs and then the quality of the diagnosis results. It is intelligent since it is a knowledge-based system including, but not only, a knowledge base, an inference engine said supervision engine and ontologies. The current work deals with the osteoporosis detection in bone radiographies. We rely on program supervision techniques that aim to automatically plan and control complex software usage. Our main contribution is to allow physicians, who are not experts in computing, to benefit from technological advances made by experts in image processing, and then to efficiently use various osteoporosis detection programs in a distributed environment.

  6. A Cloud Computing Based Patient Centric Medical Information System

    Science.gov (United States)

    Agarwal, Ankur; Henehan, Nathan; Somashekarappa, Vivek; Pandya, A. S.; Kalva, Hari; Furht, Borko

    This chapter discusses an emerging concept of a cloud computing based Patient Centric Medical Information System framework that will allow various authorized users to securely access patient records from various Care Delivery Organizations (CDOs) such as hospitals, urgent care centers, doctors, laboratories, imaging centers among others, from any location. Such a system must seamlessly integrate all patient records including images such as CT-SCANS and MRI'S which can easily be accessed from any location and reviewed by any authorized user. In such a scenario the storage and transmission of medical records will have be conducted in a totally secure and safe environment with a very high standard of data integrity, protecting patient privacy and complying with all Health Insurance Portability and Accountability Act (HIPAA) regulations.

  7. [Approaches to development and implementation of the medical information system for military-medical commission of the multidisciplinary military-medical organisation].

    Science.gov (United States)

    Kuvshinov, K E; Klipak, V M; Chaplyuk, A L; Moskovko, V M; Belyshev, D V; Zherebko, O A

    2015-06-01

    The current task of the implementation of medical information systems in the military and medical organizations is an automation of the military-medical expertise as one of the most important activities. In this regard, noteworthy experience of the 9th Medical Diagnostic Centre (9th MDC), where on the basis of medical information system "Interi PROMIS" for the first time was implemented the automation of the work of military medical commission. The given paper presents an algorithm for constructing of the information system for the military-medical examination; detailed description of its elements is given. According to military servicemen the implementation of the Military Medical Commission (MMC) subsystem of the medical information system implemented into the 9th MDC has reduced the time required for the MMC and paperwork, greatly facilitate the work of physicians and medical specialists on military servicemen examination. This software can be widely applied in ambulatory and hospital practice, especially in case of mass military-medical examinations.

  8. Data bank applications of a nuclear medical computer system

    International Nuclear Information System (INIS)

    Hale, T.I.; Jucker, A.; Haering, W.; Schmid, B.

    1980-01-01

    Computer systems in nuclear medicine are normally not used for data bank applications. A concept for a PDP-11-34 with RK 05 disc is presented, which serves the needs of data manipulations of a medium sized hospital including management of patient data, pharma stock control etc. besides specific use for nuclear medical work with absolute priority. The program is available upon request. (orig.) [de

  9. Growth of Ferromagnetic Epitaxial Film of Hexagonal FeGe on (111) Ge Surface

    Science.gov (United States)

    Kumar, Dushyant; Joshi, P. C.; Hossain, Z.; Budhani, R. C.

    2014-03-01

    The realization of semiconductors showing ferromagnetic order at easily accessible temperatures has been of interest due to their potential use in spintronic devices where long spin life times are of key interest. We have realized the growth of FeGe thin films on Ge (111) wafers using pulsed laser deposition (PLD). The stoichiometric and single phase FeGe target used in PLD chamber has been made by arc melting. A typical θ-2 θ diffraction spectra performed on 40 nm thick FeGe film suggests the stabilization of β-Ni2In (B82-type) hexagonal phase with an epitaxial orientation of (0001)FeGe ||(111)Ge and [11-20]FeGe ||[-110]Ge. SEM images shows a granular structure with the formation of very large grains of about 100 to 500 nm in lateral dimension. The magnetization vs. temperature data taken from SQUID reveal the TC of ~ 270K. Since, PLD technique makes it easier to stabilize the B82 (Ni2In) hexagonal phase in thin FeGe films, this work opens opportunities to reinvestigate many conflicting results on various properties of the FeGe system.

  10. PS-022 Complex automated medication systems reduce medication administration error rates in an acute medical ward

    DEFF Research Database (Denmark)

    Risør, Bettina Wulff; Lisby, Marianne; Sørensen, Jan

    2017-01-01

    Background Medication errors have received extensive attention in recent decades and are of significant concern to healthcare organisations globally. Medication errors occur frequently, and adverse events associated with medications are one of the largest causes of harm to hospitalised patients...... cabinet, automated dispensing and barcode medication administration; (2) non-patient specific automated dispensing and barcode medication administration. The occurrence of administration errors was observed in three 3 week periods. The error rates were calculated by dividing the number of doses with one...

  11. Study of the pπ- system produced in reaction K+n→K+π-p at 8.25GeV/c and comparison with data at 4.6 and 12GeV/c

    International Nuclear Information System (INIS)

    Vignaud, D.; Ginestet, J.; Burlaud, D.; Sene, M.

    1975-01-01

    The fragmentation of the neutron into pπ - induced by incident K + of 8.25GeV/c is studied using data from the CERN 2m deuterium bubble chamber and compared with data at 4.6 and 12GeV/c. The pπ - low mass enhancement below 1.85GeV/c is analyzed and the major part exhibits the properties expected for diffraction dissociation. The presence of resonances is discussed. The data are fairly well represented by a double Regge exchange model involving pion and Pomeron exchanges. The violation of the s-channel and t-channel helicity conservation is observed and compared to the s-channel description of Humble [fr

  12. Systemic Medication and Intraocular Pressure in a British Population

    Science.gov (United States)

    Khawaja, Anthony P.; Chan, Michelle P.Y.; Broadway, David C.; Garway-Heath, David F.; Luben, Robert; Yip, Jennifer L.Y.; Hayat, Shabina; Wareham, Nicholas J.; Khaw, Kay-Tee; Foster, Paul J.

    2014-01-01

    Objective To determine the association between systemic medication use and intraocular pressure (IOP) in a population of older British men and women. Design Population-based, cross-sectional study. Participants We included 7093 participants from the European Prospective Investigation into Cancer–Norfolk Eye Study. Exclusion criteria were a history of glaucoma therapy (medical, laser, or surgical), IOP asymmetry between eyes of >5 mmHg, and missing data for any covariables. The mean age of participants was 68 years (range, 48–92) and 56% were women. Methods We measured IOP using the Ocular Response Analyzer. Three readings were taken per eye and the best signal value of the Goldmann-correlated IOP value considered. Participants were asked to bring all their medications and related documentation to the health examination, and these were recorded by the research nurse using an electronic case record form. The medication classes examined were angiotensin-converting enzyme inhibitors, angiotensin-receptor blockers, α-blockers, β-blockers, calcium channel blockers, diuretics, nitrates, statins, insulin, biguanides, sulfonylureas, aspirin, and other nonsteroidal anti-inflammatory drugs. We examined associations between medication use and IOP using multivariable linear regression models adjusted for age, sex, and body mass index. Models containing diabetic medication were further adjusted for glycosylated hemoglobin levels. Main Outcome Measures Mean IOP of the right and left eyes. Results Use of systemic β-blockers (−0.92 mmHg; 95% CI, −1.19, −0.65; Pnitrates (−0.63 mmHg; 95% CI, −1.12, −0.14; P = 0.011) were independently associated with lower IOP. The observed associations between statin or aspirin use with IOP were no longer significant after adjustment for β-blocker use. Conclusions This is the first population-based study to demonstrate and quantify clinically significant differences in IOP among participants using systemic β-blockers or

  13. Room Temperature Ferromagnetic Mn:Ge(001

    Directory of Open Access Journals (Sweden)

    George Adrian Lungu

    2013-12-01

    Full Text Available We report the synthesis of a room temperature ferromagnetic Mn-Ge system obtained by simple deposition of manganese on Ge(001, heated at relatively high temperature (starting with 250 °C. The samples were characterized by low energy electron diffraction (LEED, scanning tunneling microscopy (STM, high resolution transmission electron microscopy (HRTEM, X-ray photoelectron spectroscopy (XPS, superconducting quantum interference device (SQUID, and magneto-optical Kerr effect (MOKE. Samples deposited at relatively elevated temperature (350 °C exhibited the formation of ~5–8 nm diameter Mn5Ge3 and Mn11Ge8 agglomerates by HRTEM, while XPS identified at least two Mn-containing phases: the agglomerates, together with a Ge-rich MnGe~2.5 phase, or manganese diluted into the Ge(001 crystal. LEED revealed the persistence of long range order after a relatively high amount of Mn (100 nm deposited on the single crystal substrate. STM probed the existence of dimer rows on the surface, slightly elongated as compared with Ge–Ge dimers on Ge(001. The films exhibited a clear ferromagnetism at room temperature, opening the possibility of forming a magnetic phase behind a nearly ideally terminated Ge surface, which could find applications in integration of magnetic functionalities on semiconductor bases. SQUID probed the co-existence of a superparamagnetic phase, with one phase which may be attributed to a diluted magnetic semiconductor. The hypothesis that the room temperature ferromagnetic phase might be the one with manganese diluted into the Ge crystal is formulated and discussed.

  14. Critical thickness of transition from 2D to 3D growth and peculiarities of quantum dots formation in GexSi1-x/Sn/Si and Ge1-ySny/Si systems

    Science.gov (United States)

    Lozovoy, Kirill A.; Kokhanenko, Andrey P.; Voitsekhovskii, Alexander V.

    2018-03-01

    Nowadays using of tin as one of the deposited materials in GeSi/Sn/Si, GeSn/Si and GeSiSn/Si material systems is one of the most topical problems. These materials are very promising for various applications in nanoelectronics and optoelectronics due to possibility of band gap management and synthesis of direct band semiconductors within these systems. However, there is a lack of theoretical investigations devoted to the peculiarities of germanium on silicon growth in the presence of tin. In this paper a new theoretical approach for modeling growth processes of binary and ternary semiconductor compounds during the molecular beam epitaxy in these systems is presented. The established kinetic model based on the general nucleation theory takes into account the change in physical and mechanical parameters, diffusion coefficient and surface energies in the presence of tin. With the help of the developed model the experimentally observed significant decrease in the 2D-3D transition temperatures for GeSiSn/Si system compared to GeSi/Si system is theoretically explained for the first time in the literature. Besides that, the derived expressions allow one to explain the experimentally observed temperature dependencies of the critical thickness, as well as to predict the average size and surface density of quantum dots for different contents and temperatures in growth experiment, that confirms applicability of the model proposed. Moreover, the established model can be easily applied to other material systems in which the Stranski-Krastanow growth mode occurs.

  15. A GEM Detector System for an Upgrade of the High-eta Muon Endcap Stations GE1/1 + ME1/1 in CMS

    CERN Document Server

    Abbaneo, D; Aspell, P.; Bianco, S.; Hoepfner, K.; Hohlmann, M.; Maggi, M.; De Lentdecker, G.; Safonov, A.; Sharma, A.; Tytgat, M.

    2012-01-01

    Based on the CMS Upgrade R&D Proposal RD10.02, we describe the motivation and main features of the CMS GEM Project for LS2 and propose the addition of a full GE1/12 detector station comprising Gas Electron Multiplier (GEM) chambers to the forward muon system of CMS. The limitations of the currently existing forward muon detector when operating at increasingly high luminosity expected after LS1 are laid out followed by a brief description of the anticipated performance improvements achievable with a GE1/1 station. The second part describes the detector system followed by an overview of electronics and associated services including a discussion of the schedule and cost of the project. Plans for a precursor demonstrator installation in LS1 are presented. This proposal is intended as a concise follow-up of the detailed document CMS-IN-2012-023. If approved, this is to be followed by a detailed Technical Design Report.

  16. Vitrification and some physical and chemical properties of glass in the BaO-B2O3-GeO2 system

    International Nuclear Information System (INIS)

    Dzhavadyan, V.G.; Kostanyan, K.A.

    1977-01-01

    The results are presented of the determination of the areas of glass-transition in RO-B 2 O-GeO 2 systems (where R=Mg, Ca, Sr, Ba) and of the study of the density, the refraction index and the coefficient of linear thermal expansion of glasses of the BaO-B 2 O 3 -GeO 2 system as a function of the composition. It is shown that the substitution of the glass forming agent in the borogermanate component by BaO leads to a non-linear growth of the density. A negative deviation is observed of the experimental variation of the molar volume from the ideal and the positive deviation of the refraction indices from the ideal values. A content of 30 % and over of BaO brings about a sharp increase in the value of the coefficient of linear thermal expansion. Changes of the m lar volume, refraction index and coefficient of linear thermal expansion of glasses as a function of their compositions is due to the variation of the coordination number of boron on charge of the BaO/B 2 O 3 ratio

  17. Human engineering design of medical x-ray system

    International Nuclear Information System (INIS)

    Tohma, Hideo

    1981-01-01

    There have been remarkable progress in the area of X-ray diagnosis technology in recent years. However, there have been some cases of accident. Such accidents included those due to defective apparatus such as defects in apparatus and poor safety system, those caused by incorrect handling of apparatus by radiologic technologist, and those originating in a poor surrounding condition or bad management of apparatus. In this report, the following subjects are statistically studied: 1. Analysis of radiographic error. 2. Analysis of failure in medical X-ray systems. (author)

  18. Hospital Based Customization of a Medical Information System

    Science.gov (United States)

    Rath, Marilyn A.; Ferguson, Julie C.

    1983-01-01

    A Medical Information System must be current if it is to be a viable adjunct to patient care within a hospital setting. Hospital-based customization provides a means of achieving this timeliness with maximum user satisfaction. It, however, requires a major commitment in personnel time as well as additional software and training expenses. The enhanced control of system modifications and overall flexibility in planning the change process result in enthusiastic support of this approach by many hospitals. The key factors for success include careful selection of local personnel with adequate vendor support, extensive QA control, thorough auditing/validation and direct user involvement.

  19. Application of object modeling technique to medical image retrieval system

    International Nuclear Information System (INIS)

    Teshima, Fumiaki; Abe, Takeshi

    1993-01-01

    This report describes the results of discussions on the object-oriented analysis methodology, which is one of the object-oriented paradigms. In particular, we considered application of the object modeling technique (OMT) to the analysis of a medical image retrieval system. The object-oriented methodology places emphasis on the construction of an abstract model from real-world entities. The effectiveness of and future improvements to OMT are discussed from the standpoint of the system's expandability. These discussions have elucidated that the methodology is sufficiently well-organized and practical to be applied to commercial products, provided that it is applied to the appropriate problem domain. (author)

  20. Development of a medical academic degree system in China.

    Science.gov (United States)

    Wu, Lijuan; Wang, Youxin; Peng, Xiaoxia; Song, Manshu; Guo, Xiuhua; Nelson, Hugh; Wang, Wei

    2014-01-01

    The Chinese government launched a comprehensive healthcare reform to tackle challenges to health equities. Medical education will become the key for successful healthcare reform. We describe the current status of the Chinese medical degree system and its evolution over the last 80 years. Progress has been uneven, historically punctuated most dramatically by the Cultural Revolution. There is a great regional disparity. Doctors with limited tertiary education may be licensed to practice, whereas medical graduates with advanced doctorates may have limited clinical skills. There are undefined relationships between competing tertiary training streams, the academic professional degree, and the clinical residency training programme (RTP). The perceived quality of training in both streams varies widely across China. As the degrees of master or doctor of academic medicine is seen as instrumental in career advancement, including employability in urban hospitals, attainment of this degree is sought after, yet is often unrelated to a role in health care, or is seen as superior to clinical experience. Meanwhile, the practical experience gained in some prestigious academic institutions is deprecated by the RTP and must be repeated before accreditation for clinical practice. This complexity is confusing both for students seeking the most appropriate training, and also for clinics, hospitals and universities seeking to recruit the most appropriate applicants. The future education reforms might include: 1) a domestic system of 'credits' that gives weight to quality clinical experience vs. academic publications in career advancement, enhanced harmonisation between the competing streams of the professional degree and the RTP, and promotion of mobility of staff between areas of excellence and areas of need; 2) International - a mutual professional and academic recognition between China and other countries by reference to the Bologna Accord, setting up a system of easily comparable and

  1. Evaluating the medical malpractice system and options for reform.

    Science.gov (United States)

    Kessler, Daniel P

    2011-01-01

    The U.S. medical malpractice liability system has two principal objectives: to compensate patients who are injured through the negligence of healthcare providers and to deter providers from practicing negligently. In practice, however, the system is slow and costly to administer. It both fails to compensate patients who have suffered from bad medical care and compensates those who haven't. According to opinion surveys of physicians, the system creates incentives to undertake cost-ineffective treatments based on fear of legal liability--to practice "defensive medicine." The failures of the liability system and the high cost of health care in the United States have led to an important debate over tort policy. How well does malpractice law achieve its intended goals? How large of a problem is defensive medicine and can reforms to malpractice law reduce its impact on healthcare spending? The flaws of the existing system have led a number of states to change their laws in a way that would reduce malpractice liability--to adopt "tort reforms." Evidence from several studies suggests that wisely chosen reforms have the potential to reduce healthcare spending significantly with no adverse impact on patient health outcomes.

  2. Minimal impact of an electronic medical records system.

    Science.gov (United States)

    Tall, Jill M; Hurd, Marie; Gifford, Thomas

    2015-05-01

    Electronic medical records (EMRs) implementation in hospitals and emergency departments (EDs) is becoming increasingly more common. The purpose of this study was to determine the impact of an EMR system on patient-related factors that correlate to ED workflow efficiency. A retrospective chart review assessed monthly census reports of all patients who registered and were treated to disposition during conversion from paper charts to an EMR system. The primary outcome measurement was an analysis of the time of registration to discharge or total ED length of stay as well as rate of those who left without being seen, eloped, or left against medical advice. These data were recorded from 3 periods, for 18 months: before installation of the EMR system (pre-EMR), during acclimation to the EMR, and post acclimation (post-EMR). A total of 61626 individual patient records were collected and analyzed. The total ED length of stay across all patient subtypes was not significantly affected by the installation of the hospital-wide EMR system (P = .481); however, a significant decrease was found for patients who were admitted to the hospital from the ED (P .25). Installation of a hospital-wide EMR system had minimal impact on workflow efficiency parameters in an ED. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Organizative structure of the System for Integral Management of Archive Documents (SiGeID 1.0

    Directory of Open Access Journals (Sweden)

    Irima Campillo Torres

    2012-04-01

    Full Text Available El nuevo contexto impone a las organizaciones la necesidad vital de disponer de adecuadas infraestructuras de comunicación, que les permitan conseguir un conocimiento real y suficiente del entorno. El presente artículo pretende mostrar la estructura organizativa del Sistema de Gestión Integral de Documentos de archivo SiGeID (1.0, como una herramienta informática que ayuda a las organizaciones empresariales al perfeccionamiento de la gestión de documentos. Dividido en tres módulos: Gestión y Seguridad Documental, Gestión de Archivo y Administración y Configuración, se tienen en cuenta además sus requerimientos funcionales y no funcionales

  4. K/sup -/p interactions at 11 GeV/c: new results on strange meson systems

    Energy Technology Data Exchange (ETDEWEB)

    Ratcliff, B.N.

    1980-06-01

    The status of our programmatic study of states containing a strange quark is briefly reviewed. An 11 GeV/c K/sup -/p experiment run on the LASS spectrometer at SLAC is discussed and preliminary results presented for several inelastic channels based on approximately one half of the available data sample. In addition, new results utilizing the full statistics of the experiment are presented for the elastic K/sup -/..pi../sup +/ channel from the K/sup -/..pi../sup +/n final state. The well established leading K*(890), K*(1435), and K*(1780) resonances are observed, and clear evidence is presented for a new J/sup p/ = 4/sup +/ resonance at approx. 2070 MeV. Preliminary results from an energy independent partial wave analysis of these data are presented which display unambiguous evidence for resonant structure in the non-leading 0/sup +/ and 1/sup -/ waves.

  5. System, centrality, and transverse mass dependence of two-pion correlation radii in heavy ion collisions at 11.6A and 14.6A GeV/c

    International Nuclear Information System (INIS)

    Ahle, L.; Baker, M.D.; Cianciolo, V.; Costales, J.B.; Dunlop, J.C.; Heintzelman, G.; Judd, E.; Kehoe, W.L.; Ledoux, R.J.; Morrison, D.P.; Morse, R.J.; Ogilvie, C.A.; Parsons, C.G.; Rothschild, P.; Soltz, R.A.; Steadman, S.G.; Stephans, G.S.F.; Sung, T.W.; Vutsadakis, V.; Woodruff, D.

    2002-01-01

    Two-pion correlation functions are analyzed at midrapidity for three systems (14.6A GeV/c Si+Al, Si+Au, and 11.6A GeV/c Au+Au), seven distinct centrality conditions, and different k T bins in the range 0.1-0.5 GeV/c. Source reference frames are determined from fits to the Yano-Koonin source parametrization. Bertsch-Pratt radius parameters are shown to scale linearly with both number of projectile and total participants as obtained from a Glauber model calculation. A finite lifetime parameter that increases linearly with system/centrality is also reported. The m T dependences of the Bertsch-Pratt radii for the central Si+Au and central Au+Au systems differ only by an overall normalization factor given by the measured system/centrality dependence

  6. Implementing electronic medical record systems in developing countries

    Directory of Open Access Journals (Sweden)

    Hamish Fraser

    2005-06-01

    Full Text Available The developing world faces a series of health crises including HIV/AIDS and tuberculosis that threaten the lives of millions of people. Lack of infrastructure and trained, experienced staff are considered important barriers to scaling up treatment for these diseases. In this paper we explain why information systems are important in many healthcare projects in the developing world. We discuss pilot projects demonstrating that such systems are possible and can expand to manage hundreds of thousands of patients. We also pass on the most important practical lessons in design and implementation from our experience in doing this work. Finally, we discuss the importance of collaboration between projects in the development of electronic medical record systems rather than reinventing systems in isolation, and the use of open standards and open source software.

  7. Three-dimensional reconstruction and visualization system for medical images

    International Nuclear Information System (INIS)

    Preston, D.F.; Batnitzky, S.; Kyo Rak Lee; Cook, P.N.; Cook, L.T.; Dwyer, S.J.

    1982-01-01

    A three-dimensional reconstruction and visualization system could be of significant advantage in medical application such as neurosurgery and radiation treatment planning. The reconstructed anatomic structures from CT head scans could be used in a head stereotactic system to help plan the surgical procedure and the radiation treatment for a brain lesion. Also, the use of three-dimensional reconstruction algorithm provides for quantitative measures such as volume and surface area estimation of the anatomic features. This aspect of the three-dimensional reconstruction system may be used to monitor the progress or staging of a disease and the effects of patient treatment. Two cases are presented to illustrate the three-dimensional surface reconstruction and visualization system

  8. A Novel Medical E-Nose Signal Analysis System

    Directory of Open Access Journals (Sweden)

    Lu Kou

    2017-04-01

    Full Text Available It has been proven that certain biomarkers in people’s breath have a relationship with diseases and blood glucose levels (BGLs. As a result, it is possible to detect diseases and predict BGLs by analysis of breath samples captured by e-noses. In this paper, a novel optimized medical e-nose system specified for disease diagnosis and BGL prediction is proposed. A large-scale breath dataset has been collected using the proposed system. Experiments have been organized on the collected dataset and the experimental results have shown that the proposed system can well solve the problems of existing systems. The methods have effectively improved the classification accuracy.

  9. Exposure management systems in emergencies as comprehensive medical care

    International Nuclear Information System (INIS)

    Shinohara, Teruhiko

    2000-01-01

    The emergency management of nuclear hazards relies on a comprehensive medical care system that includes accident prevention administration, environmental monitoring, a health physics organization, and a medical institution. In this paper, the care organization involved in the criticality accident at Tokai-mura is described, and the problems that need to be examined are pointed out. In that incident, even the expert was initially utterly confused and was unable to take appropriate measures. The author concluded that the members of the care organization were all untrained for dealing with nuclear hazards and radiation accidents. The education and training of personnel at the job site are important, and they are even more so for the leaders. Revisions of the regional disaster prevention plans and care manual are needed. (K.H.)

  10. A unified framework for data modeling on medical information systems.

    Science.gov (United States)

    Neves, J; Cortez, P; Rocha, M; Abelha, A; Machado, J; Alves, V; Basto, S; Botelho, H; Neves, J

    1999-01-01

    Medical Information Systems (MIS) are seen as a way of optimizing the use of existing health-care infrastructure, without resorting to new and costly hospital (re)construction. The qualitative (re)design of such an environment requires a basic understanding of patient and doctors related characteristics and capabilities. Patient care, patient education, medical education, and clinical research need to be considered to meet the basic requirements on the level of services desirable, determined on the basis of the patient's length of stay; i.e., used for modeling the significant entities of such a world. The aim is to extract conclusions for the level of services provided to the users. One's concept will capture, as well as will integrate, the basic design principles under which MIS may be set.

  11. Robust anonymous authentication scheme for telecare medical information systems.

    Science.gov (United States)

    Xie, Qi; Zhang, Jun; Dong, Na

    2013-04-01

    Patient can obtain sorts of health-care delivery services via Telecare Medical Information Systems (TMIS). Authentication, security, patient's privacy protection and data confidentiality are important for patient or doctor accessing to Electronic Medical Records (EMR). In 2012, Chen et al. showed that Khan et al.'s dynamic ID-based authentication scheme has some weaknesses and proposed an improved scheme, and they claimed that their scheme is more suitable for TMIS. However, we show that Chen et al.'s scheme also has some weaknesses. In particular, Chen et al.'s scheme does not provide user's privacy protection and perfect forward secrecy, is vulnerable to off-line password guessing attack and impersonation attack once user's smart card is compromised. Further, we propose a secure anonymity authentication scheme to overcome their weaknesses even an adversary can know all information stored in smart card.

  12. Medical Signal-Conditioning and Data-Interface System

    Science.gov (United States)

    Braun, Jeffrey; Jacobus, charles; Booth, Scott; Suarez, Michael; Smith, Derek; Hartnagle, Jeffrey; LePrell, Glenn

    2006-01-01

    A general-purpose portable, wearable electronic signal-conditioning and data-interface system is being developed for medical applications. The system can acquire multiple physiological signals (e.g., electrocardiographic, electroencephalographic, and electromyographic signals) from sensors on the wearer s body, digitize those signals that are received in analog form, preprocess the resulting data, and transmit the data to one or more remote location(s) via a radiocommunication link and/or the Internet. The system includes a computer running data-object-oriented software that can be programmed to configure the system to accept almost any analog or digital input signals from medical devices. The computing hardware and software implement a general-purpose data-routing-and-encapsulation architecture that supports tagging of input data and routing the data in a standardized way through the Internet and other modern packet-switching networks to one or more computer(s) for review by physicians. The architecture supports multiple-site buffering of data for redundancy and reliability, and supports both real-time and slower-than-real-time collection, routing, and viewing of signal data. Routing and viewing stations support insertion of automated analysis routines to aid in encoding, analysis, viewing, and diagnosis.

  13. Study of Ge loss during Ge condensation process

    International Nuclear Information System (INIS)

    Xue, Z.Y.; Di, Z.F.; Ye, L.; Mu, Z.Q.; Chen, D.; Wei, X.; Zhang, M.; Wang, X.

    2014-01-01

    Ge loss during Ge condensation process was investigated by transmission electron microscopy, Raman spectroscopy, secondary ion mass spectrometry and Rutherford backscattering spectrometry. This work reveals that Ge loss can be attributed to the Ge oxidation at SiO 2 /SiGe interface, Ge diffusion in SiO 2 layers and Ge trapped at buried SiO 2 /Si interface. During Ge condensation process, with the increase of the Ge content, the Si atoms become insufficient for selective oxidation at the oxide/SiGe interface. Consequently, the Si and Ge are oxidized simultaneously. When the Ge composition in SiGe layer increases further and approaches 100%, the Ge atoms begin to diffuse into the top SiO 2 layer and buried SiO 2 layer. However, the X-ray photoelectron spectrometry analysis manifests that the chemical states of the Ge in top SiO 2 layer are different from those in buried SiO 2 layer, as the Ge atoms diffused into top SiO 2 layer are oxidized to form GeO 2 in the subsequent oxidation step. With the increase of the diffusion time, a quantity of Ge atoms diffuse through buried SiO 2 layer and pile up at buried SiO 2 /Si interface due to the interfacial trapping. The SiO 2 /Si interface acts like a pump, absorbing Ge from a Ge layer continuously through a pipe-buried SiO 2 layer. With the progress of Ge condensation process, the quantity of Ge accumulated at SiO 2 /Si interface increases remarkably. - Highlights: • Ge loss during Ge condensation process is attributed to the Ge oxidation at SiO 2 /SiGe interface. • Ge diffusion in SiO 2 layers and Ge trapped at buried SiO 2 /Si interface • When Ge content in SiGe layer approaches 100%, Ge diffusion into the SiO 2 layer is observed. • Ge then gradually diffuses through buried SiO 2 layer and pile up at SiO 2 /Si interface

  14. Handling medical negligence: necessity of a proper system

    Directory of Open Access Journals (Sweden)

    Nuwadatta Subedi

    2017-12-01

    field by the councils framed to settle the cases of medical negligence, especially the consumer protection council, Nepal Medical Council, etc.It is a high time for the government to play role to address to this sensitive and quai-legal issue. If this trend is not ended, the trust of patients towards the doctors may nullify. The doctors also cannot work effectively when there is no safe working environment and may begin to have tendency to abandon handling critical cases with a fear of vulnerability to defamation if not physical assault in worst case. The situation is ultimately disastrous to the entire health care system. The very sensitive issue of health care delivery cannot be compared to any other commercial issues. The proper mechanism of addressing the issue of medical negligence should be practiced alongside encouragement from governmental urge to come up with better medicolegal systems in this regard. This is highly essential for balancing expectations of the patients and performance of medical professionals.

  15. Nephrogenic systemic fibrosis associated with gadolinium based contrast agents: A summary of the medical literature reporting

    International Nuclear Information System (INIS)

    Broome, Dale R.

    2008-01-01

    Nephrogenic systemic fibrosis (NSF) is a systemic fibrosing disorder that principally affects the skin, but can involve virtually any tissue in the human body and result in significant disability and even death. Since 2006 numerous retrospective case reports and case series have reported a very strong association of this disease with exposure to gadolinium-based contrast agents (Gd-CA) for MR imaging in the setting of severe or end-stage renal disease. The purpose of this report is to summarize the medical literature reporting of biopsy-proven NSF cases in which the authors specifically investigated patient exposure to Gd-CA. A Pub Med MEDLINE search was performed using the key words-nephrogenic systemic fibrosis and nephrogenic fibrosing dermopathy. All case reports and case series of NSF were reviewed to determine if patients had a preceding exposure to Gd-CA and which specific Gd-CA was involved. If the original reports did not clarify the specific Gd-CA, I reviewed follow-up letters to the editors or contacted the authors to clarify which specific Gd-CA were linked to the NSF cases. If several reports originated from the same institution, clarification was also obtained to avoid redundant reporting. As of February 1, 2008 there have been 190 biopsy-proven cases of NSF published in the peer-reviewed literature with the following associations: 157 gadodiamide (Omniscan, GE Healthcare), 8 gadopentetate (Magnevist, Bayer Healthcare), 3 gadoversetamide (OptiMARK, Covidien), and 18 unspecified Gd-CA, and 4 confounded cases with more than one Gd-CA. Five cases of NSF were unassociated with Gd-CA

  16. Development of Patient Status-Based Dynamic Access System for Medical Information Systems

    Directory of Open Access Journals (Sweden)

    Chang Won Jeong

    2015-06-01

    Full Text Available Recently, the hospital information system environment using IT communication technology and utilization of medical information has been increasing. In the medical field, the medical information system only supports the transfer of patient information to medical staff through an electronic health record, without information about patient status. Hence, it needs a method of real-time monitoring for the patient. Also, in this environment, a secure method in approaching healthcare through various smart devices is required. Therefore, in this paper, in order to classify the status of the patients, we propose a dynamic approach of the medical information system in a hospital information environment using the dynamic access control method. Also, we applied the symmetric method of AES (Advanced Encryption Standard. This was the best encryption algorithm for sending and receiving biological information. We can define usefulness as the dynamic access application service based on the final result of the proposed system. The proposed system is expected to provide a new solution for a convenient medical information system.

  17. Bayesian Islamic medication expert system (B-IMES)

    Science.gov (United States)

    Daud, Hanita; Razali, Radzuan; Jung, Low Tan; Zaida, Shahnaz

    2015-12-01

    This paper discusses on the development of an expert system (ES) that applies Bayesian Probability concept for Islamic Medication practice that is made available on web platform. This ES allows user to choose sickness such as headache, stomachache, toothache and etc that he/she may have and list of symptoms related to the sickness will appear for the user to choose. Once symptom(s) is/are chosen the diagnosis is being carried out to suggest percentage of possible specific sickness such as classic migraine, common migraine, tension headache and etc if headache was chosen. This diagnosis is being carried out using Bayes' Theorem and the ES will suggest the treatments or therapy that he/she needs to perform in reference to Muslim Holy Quran and Hadith. This ES was developed to preserve Islamic medication and to create awareness among the young generation and make it accessible at anytime and anywhere and to save users time to meet Islamic Medication practitioners who are not easily available in Malaysia and other parts of the world.

  18. Benefits and problems in implementation for integrated medical information system

    International Nuclear Information System (INIS)

    Park, Chang Seo; Kim, Kee Deog; Park, Hyok; Jeong, Ho Gul

    2005-01-01

    Once the decision has been made to adopt an integrated medical information system (IMIS), there are a number of tissues to overcome. Users need to be aware of the impact the change will make on end users and be prepared to address issues that arise before they become problems. The purpose of this study is to investigate the benefits and unexpected problems encountered in the implementation of IMIS and to determine a useful framework for IMIS. The Yonsei University Dental Hospital is steadily constructing an IMIS. The vendor's PACS software, Piview STAR, supports transactions between workstations that are approved to integrating the health care enterprise (IHE) with security function. It is necessary to develop an excellent framework that is good for the patient, health care provider and information system vendors, in an expert, efficient, and cost-effective manner. The problems encountered with IMIS implementation were high initial investments, delay of EMR enforcement, underdevelopment of digital radiographic appliances and software and insufficient educational training for users. The clinical environments of dental IMIS is some different from the medical situation. The best way to overcome these differences is to establish a gold standard of dental IMIS integration, which estimates the cost payback. The IHE and its technical framework are good for the patient, the health care provider and all information systems vendors.

  19. AI empowered context-aware smart system for medication adherence

    Directory of Open Access Journals (Sweden)

    Qiong Wu

    2017-06-01

    Full Text Available Purpose – Poor medication adherence leads to high hospital admission rate and heavy amount of health-care cost. To cope with this problem, various electronic pillboxes have been proposed to improve the medication adherence rate. However, most of the existing electronic pillboxes use time-based reminders which may often lead to ineffective reminding if the reminders are triggered at inopportune moments, e.g. user is sleeping or eating. Design/methodology/approach – In this paper, the authors propose an AI-empowered context-aware smart pillbox system. The pillbox system collects real-time sensor data from a smart home environment and analyzes the user’s contextual information through a computational abstract argumentation-based activity classifier. Findings – Based on user’s different contextual states, the smart pillbox will generate reminders at appropriate time and on appropriate devices. Originality/value – This paper presents a novel context-aware smart pillbox system that uses argumentation-based activity recognition and reminder generation.

  20. Regenstrief Institute's Medical Gopher: a next-generation homegrown electronic medical record system.

    Science.gov (United States)

    Duke, Jon D; Morea, Justin; Mamlin, Burke; Martin, Douglas K; Simonaitis, Linas; Takesue, Blaine Y; Dixon, Brian E; Dexter, Paul R

    2014-03-01

    Regenstrief Institute developed one of the seminal computerized order entry systems, the Medical Gopher, for implementation at Wishard Hospital nearly three decades ago. Wishard Hospital and Regenstrief remain committed to homegrown software development, and over the past 4 years we have fully rebuilt Gopher with an emphasis on usability, safety, leveraging open source technologies, and the advancement of biomedical informatics research. Our objective in this paper is to summarize the functionality of this new system and highlight its novel features. Applying a user-centered design process, the new Gopher was built upon a rich-internet application framework using an agile development process. The system incorporates order entry, clinical documentation, result viewing, decision support, and clinical workflow. We have customized its use for the outpatient, inpatient, and emergency department settings. The new Gopher is now in use by over 1100 users a day, including an average of 433 physicians caring for over 3600 patients daily. The system includes a wizard-like clinical workflow, dynamic multimedia alerts, and a familiar 'e-commerce'-based interface for order entry. Clinical documentation is enhanced by real-time natural language processing and data review is supported by a rapid chart search feature. As one of the few remaining academically developed order entry systems, the Gopher has been designed both to improve patient care and to support next-generation informatics research. It has achieved rapid adoption within our health system and suggests continued viability for homegrown systems in settings of close collaboration between developers and providers. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  1. Bi surfactant mediated growth for fabrication of Si/Ge nanostructures and investigation of Si/Ge intermixing by STM

    Energy Technology Data Exchange (ETDEWEB)

    Paul, N.

    2007-10-26

    In the thesis work presented here, we show that Bi is more promising surfactant material than Sb. We demonstrate that by using Bi as a terminating layer on Ge/Si surface, it is possible to distinguish between Si and Ge in Scanning tunnelling microscope (STM). Any attempt to utilize surfactant mediated growth must be preceded by a thorough study of its effect on the the system being investigated. Thus, the third chapter of this thesis deals with an extensive study of the Bi surfactant mediated growth of Ge on Si(111) surface as a function of Ge coverage. The growth is investigated from the single bilayer Ge coverage till the Ge coverage of about 15 BL when the further Ge deposition leads to two-dimensional growth. In the fourth chapter, the unique property of Bi terminating layer on Ge/Si surface to result in an STM height contrast between Si and Ge is explained with possible explanations given for the reason of this apparent height contrast. The controlled fabrication of Ge/Si nanostructures such as nanowires and nanorings is demonstrated. A study on Ge-Si diffusion in the surface layers by a direct method such as STM was impossible previously because of the similar electronic structure of Ge and Si. Since with the Bi terminating surface layer, one is able to distinguish between Ge and Si, the study of intermixing between them is also possible using STM. This method to distinguish between Si and Ge allows one to study intermixing on the nanoscale and to identify the fundamental diffusion processes giving rise to the intermixing. In Chapter 5 we discuss how this could prove useful especially as one could get a local probe over a very narrow Ge-Si interface. A new model is proposed to estimate change in the Ge concentration in the surface layer with time. The values of the activation energies of Ge/Si exchange and Si/Ge exchange are estimated by fitting the experimental data with the model. The Ge/Si intermixing has been studied on a surface having 1 ML Bi ({radical

  2. The Impact of CPOE Medication Systems' Design Aspects on Usability, Workflow and Medication Orders A Systematic Review

    NARCIS (Netherlands)

    Khajouei, R.; Jaspers, M. W. M.

    2010-01-01

    Objectives: To examine the impact of design aspects of computerized physician order entry (CPOE) systems for medication ordering on usability, physicians' workflow and on medication orders. Methods: We systematically searched Pub-Med, EMBASE and Ovid MEDLINE for articles published from 1986 to 2007.

  3. [The Purpose of Medical Education: Proposal to Standardize a System of Credits for Medical Specializations Programs].

    Science.gov (United States)

    Cañar, Carlos Andrés Pineda

    2012-01-01

    This article analyzes the concept of an academic credit system and proposes a way to systematize medical specialization programs. The credit system is a way to recognize and standardize the total time that a student must devote to their training. Thus, a credit equal to a certain number of hours of classroom training and independent activities is proposed. An educational program is expressed in the number of credits needed for the whole training process to achieve the competencies expected. A review of the concept of competition in education is also performed. The introduction of the term and its relation to the need to measure performance in future professionals according to labor market needs is identified. A critical discussion about skills defining the different types of skills in the educational field is later discussed. Subsequently, the Colombian regulatory framework is presented concerning the powers, in particular, Decree 1295 of 2010, which defines one academic credit equal to 48 hours in a semester, of which 16 hours are classroom and 32 hours are independent study. A tor of the major milestones in the history of medical education is later made. The structure of credits and contact hours, independent of postgraduate psychiatry in the country is reviewed showing the heterogeneity in their approach. The proposal is presented, defining the types of classroom activities and how to calculate the hours of independent study by type of classroom activity. Copyright © 2012 Asociación Colombiana de Psiquiatría. Publicado por Elsevier España. All rights reserved.

  4. Emerging Security Mechanisms for Medical Cyber Physical Systems.

    Science.gov (United States)

    Kocabas, Ovunc; Soyata, Tolga; Aktas, Mehmet K

    2016-01-01

    The following decade will witness a surge in remote health-monitoring systems that are based on body-worn monitoring devices. These Medical Cyber Physical Systems (MCPS) will be capable of transmitting the acquired data to a private or public cloud for storage and processing. Machine learning algorithms running in the cloud and processing this data can provide decision support to healthcare professionals. There is no doubt that the security and privacy of the medical data is one of the most important concerns in designing an MCPS. In this paper, we depict the general architecture of an MCPS consisting of four layers: data acquisition, data aggregation, cloud processing, and action. Due to the differences in hardware and communication capabilities of each layer, different encryption schemes must be used to guarantee data privacy within that layer. We survey conventional and emerging encryption schemes based on their ability to provide secure storage, data sharing, and secure computation. Our detailed experimental evaluation of each scheme shows that while the emerging encryption schemes enable exciting new features such as secure sharing and secure computation, they introduce several orders-of-magnitude computational and storage overhead. We conclude our paper by outlining future research directions to improve the usability of the emerging encryption schemes in an MCPS.

  5. SatCom Systems for Health and Medical Care

    Science.gov (United States)

    Diez, Hubert

    2002-01-01

    Convinced since 1997 that the satellite was capable of providing a real added value either autonomously or as a complement to terrestrial infrastructures, CNES (the French Space Agency) began a determined study, validation and demonstration procedure for new satellite services. At a national but also European and worldwide level, several experiments or projects have been set-up. In each of them (tele-consultations, distant education, tele-epidemiology, tele-echography, assistance to people, training and therapeutic assistance, disaster telemedicine, etc...) well suited satcoms are used. (telecommunications for broadcasting, multicasting, downloading,...- localization, positioning, - low medium and high data rate bidirectional systems,). Medical reference people are associated in each pilot projects first to define the needs but also to manage the medical validation aspects. Our aim is always to test, validate and adapt these new services to bring them into line with the users' expectations. The value added of these technologies in sustainable healthcare services are systematically demonstrated in real situations, with real users, both in terms of quality of service and of economic validity. For several projects CNES has developed typical hardware, or technical on as technical platform. The main projects and their relevant satcom systems will be presented and discussed : - Tele-consultation, - Distance learning and training, - Assistance to people, - Tele-epidemiology, - Disaster telemedicine.

  6. Medical data transmission system for remote healthcare centres

    International Nuclear Information System (INIS)

    Gonzalez, E A; Cagnolo, F J; Olmos, C E; Centeno, C A; Riva, G G; Zerbini, C A

    2007-01-01

    The main motivation of this project is to improve the healthcare centres equipment and human resources efficiency, enabling those centres for transmission of parameters of medical interest. This system facilitates remote consultation, in particular between specialists and remote healthcare centres. Likewise it contributes to the qualification of professionals. The electrocardiographic (ECG) and electroencephalographic (EEG) signals are acquired, processed and then sent, fulfilling the effective norms, for application in the hospital network of Cordoba Province, which has nodes interconnected by phone line. As innovative aspects we emphasized the low cost of development and maintenance, great versatility and handling simplicity with a modular design for interconnection with diverse data transmission media (Wi-Fi, GPRS, etc.). Successfully experiences were obtained during the acquisition of the signals and transmissions on wired LAN networks. As improvements, we can mention: energy consumption optimization and mobile communication systems usage, in order to offer more autonomy

  7. System theory in medical diagnostic devices: an overview.

    Science.gov (United States)

    Baura, Gail D

    2006-01-01

    Medical diagnostics refers to testing conducted either in vitro or in vivo to provide critical health care information for risk assessment, early diagnosis, treatment, or disease management. Typical in vivo diagnostic tests include the computed tomography scan, magnetic resonance imaging, and blood pressure screening. Typical in vitro diagnostic tests include cholesterol, Papanicolaou smear, and conventional glucose monitoring tests. Historically, devices associated with both types of diagnostics have used heuristic curve fitting during signal analysis. However, since the early 1990s, a few enterprising engineers and physicians have used system theory to improve their core processing for feature detection and system identification. Current applications include automated Pap smear screening for detection of cervical cancer and diagnosis of Alzheimer's disease. Future applications, such as disease prediction before symptom onset and drug treatment customization, have been catalyzed by the Human Genome Project.

  8. Academic entrepreneurship in a medical university: A system dynamics approach

    Directory of Open Access Journals (Sweden)

    Tofighi Sharam

    2017-01-01

    Full Text Available Academic entrepreneurship is a dynamic field which is growing after the second academic revolution that added entrepreneurial mission as the Third Mission of universities. In this sense, dynamics of this phenomenon is a suitable field of study and provides fruitful insights for both theory and practice. Thus, in this research, system dynamics approach is used to scrutinize academic entrepreneurship. The main question of this research is 'how academic entrepreneurship might evolve in a medical university of a developing country?' Therefore, Cross Impact Analysis method is used to examine the system behavior. In this study, the main attributes are adapted from a recent study by Salamzadeh et al. (2013a. Then, some policy variables are proposed and their effects on the model were shown. Findings show that although entrepreneurial ecosystem is growing in the country, still there are problems to be taken into account in order to improve the entrepreneurship in university.

  9. Studies on the preparation of {sup 68}Ge-{sup 68}Ga generator with inorganic materials

    Energy Technology Data Exchange (ETDEWEB)

    Brambilla, Tania P.; Osso Junior, Joao A., E-mail: jaosso@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    {sup 68}Ga as a positron emitter is of great interest because of some important advantages. It has a physical half-life of 67.71 min, which is compatible with the pharmacokinetics of many radiopharmaceuticals of low molecular weight. Other important characteristic is its cyclotron-independent availability via the {sup 68}Ge-{sup 68}Ga radionuclide generator system. In Brazil only one positron emitter radionuclide is produced, {sup 18}F, and the medical class has a great interest in using {sup 68}Ga labeled molecules, in particular peptides such as DOTA-octriotide. A project for developing a home made {sup 68}Ge-{sup 68}Ga is under way at IPEN-CNEN/SP. The aim of this work is to develop an efficient and simplified generator system of {sup 68}Ge-{sup 68}Ga that offers {sup 68}Ga{sup 3+} adequate for clinical use. Initial results will be reported concerning the behavior of Ge and Ga in adsorbers such as calcined acid and basic Al{sub 2}O{sub 3}, HZO (hydrous zirconium oxide), TiO{sub 2}, microspheres of Zr (Zr mic) and microspheres of Al (Al mic). Adsorption studies were carried out using {gamma}-emitting tracers, {sup 67}Ga and {sup 68}Ga and chemical tracer, GeO{sub 2}. The samples containing {sup 67}/{sup 68}Ga were analysed using a dose calibrator CRC-15R from Capintec and the samples containing Ge were evaluated by the Optical Emission Spectrometry using Inductively Coupled Plasma (ICP-OES). The ICP-OES equipment used was a Varian Vista-MPX from Varian and calibration curves for Ge were constructed in the range of 0.2 to 1.0 {mu}g.mL{sup -1}. The use of basic Al{sub 2}O{sub 3}, TiO{sub 2}, HZO and Zr mic showed the more promising results. (author)

  10. Implementing a Quality Management System in the Medical Microbiology Laboratory.

    Science.gov (United States)

    Carey, Roberta B; Bhattacharyya, Sanjib; Kehl, Sue C; Matukas, Larissa M; Pentella, Michael A; Salfinger, Max; Schuetz, Audrey N

    2018-07-01

    This document outlines a comprehensive practical approach to a laboratory quality management system (QMS) by describing how to operationalize the management and technical requirements described in the ISO 15189 international standard. It provides a crosswalk of the ISO requirements for quality and competence for medical laboratories to the 12 quality system essentials delineated by the Clinical and Laboratory Standards Institute. The quality principles are organized under three main categories: quality infrastructure, laboratory operations, and quality assurance and continual improvement. The roles and responsibilities to establish and sustain a QMS are outlined for microbiology laboratory staff, laboratory management personnel, and the institution's leadership. Examples and forms are included to assist in the real-world implementation of this system and to allow the adaptation of the system for each laboratory's unique environment. Errors and nonconforming events are acknowledged and embraced as an opportunity to improve the quality of the laboratory, a culture shift from blaming individuals. An effective QMS encourages "systems thinking" by providing a process to think globally of the effects of any type of change. Ultimately, a successful QMS is achieved when its principles are adopted as part of daily practice throughout the total testing process continuum. Copyright © 2018 American Society for Microbiology.

  11. Assessing the impact of a medical image access system

    Science.gov (United States)

    McNeill, Kevin M.; Maloney, Kris; Parra, Miguel V.; Ovitt, Theron W.; Dallas, William J.

    1994-05-01

    We have developed and installed a Medical Image Access System in an intensive care unit. Images are acquired and transmitted automatically to this system, thus expanding on the previous results of Shile et. al. It is our goal to determine what effect regular, sustained availability of image data in the clinic has on the Intensive Care Unit and the Department of Radiology. Our system is installed and has been in regular use in the hospital since late August of 1993. Since the time of installation we have been collecting usage information from both the manual and automated systems. From this data we are performing the standard measures established by DeSimone et. al. Our initial results support the original findings that image availability in the clinic leads to earlier patient care decision based on the image data. However, our findings do not seem to indicate that there is a breakdown of communication between the clinician and the radiologist as a result of the use of the clinical display system. In addition to the established measure we are investigating other criteria to measure time saved by both the clinician and radiologist. The results are reported in this paper.

  12. On-line integration of computer controlled diagnostic devices and medical information systems in undergraduate medical physics education for physicians.

    Science.gov (United States)

    Hanus, Josef; Nosek, Tomas; Zahora, Jiri; Bezrouk, Ales; Masin, Vladimir

    2013-01-01

    We designed and evaluated an innovative computer-aided-learning environment based on the on-line integration of computer controlled medical diagnostic devices and a medical information system for use in the preclinical medical physics education of medical students. Our learning system simulates the actual clinical environment in a hospital or primary care unit. It uses a commercial medical information system for on-line storage and processing of clinical type data acquired during physics laboratory classes. Every student adopts two roles, the role of 'patient' and the role of 'physician'. As a 'physician' the student operates the medical devices to clinically assess 'patient' colleagues and records all results in an electronic 'patient' record. We also introduced an innovative approach to the use of supportive education materials, based on the methods of adaptive e-learning. A survey of student feedback is included and statistically evaluated. The results from the student feedback confirm the positive response of the latter to this novel implementation of medical physics and informatics in preclinical education. This approach not only significantly improves learning of medical physics and informatics skills but has the added advantage that it facilitates students' transition from preclinical to clinical subjects. Copyright © 2011 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  13. Teleradiology network system using the web medical image conference system with a new information security solution

    Science.gov (United States)

    Satoh, Hitoshi; Niki, Noboru; Eguchi, Kenji; Ohmatsu, Hironobu; Kusumoto, Masahiro; Kaneko, Masahiro; Kakinuma, Ryutaru; Moriyama, Noriyuki

    2012-02-01

    We have developed the teleradiology network system with a new information security solution that provided with web medical image conference system. In the teleradiology network system, the security of information network is very important subjects. We are studying the secret sharing scheme and the tokenization as a method safely to store or to transmit the confidential medical information used with the teleradiology network system. The confidential medical information is exposed to the risk of the damage and intercept. Secret sharing scheme is a method of dividing the confidential medical information into two or more tallies. Individual medical information cannot be decoded by using one tally at all. Our method has the function of automatic backup. With automatic backup technology, if there is a failure in a single tally, there is redundant data already copied to other tally. Confidential information is preserved at an individual Data Center connected through internet because individual medical information cannot be decoded by using one tally at all. Therefore, even if one of the Data Centers is struck and information is damaged due to the large area disaster like the great earthquake of Japan, the confidential medical information can be decoded by using the tallies preserved at the data center to which it escapes damage. Moreover, by using tokenization, the history information of dividing the confidential medical information into two or more tallies is prevented from lying scattered by replacing the history information with another character string (Make it to powerlessness). As a result, information is available only to those who have rightful access it and the sender of a message and the message itself are verified at the receiving point. We propose a new information transmission method and a new information storage method with a new information security solution.

  14. The Integrated Medical Model - Optimizing In-flight Space Medical Systems to Reduce Crew Health Risk and Mission Impacts

    Science.gov (United States)

    Kerstman, Eric; Walton, Marlei; Minard, Charles; Saile, Lynn; Myers, Jerry; Butler, Doug; Lyengar, Sriram; Fitts, Mary; Johnson-Throop, Kathy

    2009-01-01

    The Integrated Medical Model (IMM) is a decision support tool used by medical system planners and designers as they prepare for exploration planning activities of the Constellation program (CxP). IMM provides an evidence-based approach to help optimize the allocation of in-flight medical resources for a specified level of risk within spacecraft operational constraints. Eighty medical conditions and associated resources are represented in IMM. Nine conditions are due to Space Adaptation Syndrome. The IMM helps answer fundamental medical mission planning questions such as What medical conditions can be expected? What type and quantity of medical resources are most likely to be used?", and "What is the probability of crew death or evacuation due to medical events?" For a specified mission and crew profile, the IMM effectively characterizes the sequence of events that could potentially occur should a medical condition happen. The mathematical relationships among mission and crew attributes, medical conditions and incidence data, in-flight medical resources, potential clinical and crew health end states are established to generate end state probabilities. A Monte Carlo computational method is used to determine the probable outcomes and requires up to 25,000 mission trials to reach convergence. For each mission trial, the pharmaceuticals and supplies required to diagnose and treat prevalent medical conditions are tracked and decremented. The uncertainty of patient response to treatment is bounded via a best-case, worst-case, untreated case algorithm. A Crew Health Index (CHI) metric, developed to account for functional impairment due to a medical condition, provides a quantified measure of risk and enables risk comparisons across mission scenarios. The use of historical in-flight medical data, terrestrial surrogate data as appropriate, and space medicine subject matter expertise has enabled the development of a probabilistic, stochastic decision support tool capable of

  15. Parkinson disease: systemic and orofacial manifestations, medical and dental management.

    Science.gov (United States)

    Friedlander, Arthur H; Mahler, Michael; Norman, Keith M; Ettinger, Ronald L

    2009-06-01

    More than 1.5 million Americans have Parkinson disease (PD), and this figure is expected to rise as the population ages. However, the dental literature offers little information about the illness. The authors conducted a MEDLINE search using the key terms "Parkinson's disease," "medical management" and "dentistry." They selected contemporaneous articles published in peer-reviewed journals and gave preference to articles reporting randomized controlled trials. PD is a progressive neurodegenerative disorder caused by loss of dopaminergic and nondopaminergic neurons in the brain. These deficits result in tremor, slowness of movement, rigidity, postural instability and autonomic and behavioral dysfunction. Treatment consists of administering medications that replace dopamine, stimulate dopamine receptors and modulate other neurotransmitter systems. Oral health may decline because of tremors, muscle rigidity and cognitive deficits. The dentist should consult with the patient's physician to establish the patient's competence to provide informed consent and to determine the presence of comorbid illnesses. Scheduling short morning appointments that begin 90 minutes after administration of PD medication enhances the patient's ability to cooperate with care. Inclination of the dental chair at 45 degrees, placement of a bite prop, use of a rubber dam and high-volume oral evacuation enhance airway protection. To avoid adverse drug interactions with levodopa and entacapone, the dentist should limit administration of local anesthetic agents to three cartridges of 2 percent lidocaine with 1:100,000 epinephrine per half hour, and patients receiving selegiline should not be given agents containing epinephrine or levonordefrin. The dentist should instruct the patient and the caregiver in good oral hygiene techniques.

  16. Ge-rich graded-index Si1-xGex devices for MID-IR integrated photonics

    Science.gov (United States)

    Ramirez, J. M.; Vakarin, V.; Liu, Q.; Frigerio, J.; Ballabio, A.; Le Roux, X.; Benedikovic, D.; Alonso-Ramos, C.; Isella, G.; Vivien, L.; Marris-Morini, D.

    2018-02-01

    Mid-infrared (mid-IR) silicon photonics is becoming a prominent research with remarkable potential in several applications such as in early medical diagnosis, safe communications, imaging, food safety and many more. In the quest for the best material platform to develop new photonic systems, Si and Ge depart with a notable advantage over other materials due to the high processing maturity accomplished during the last part of the 20th century through the deployment of the CMOS technology. From an optical viewpoint, combining Si with Ge to obtain SiGe alloys with controlled stoichiometry is also of interest for the photonic community since permits to increase the effective refractive index and the nonlinear parameter, providing a fascinating playground to exploit nonlinear effects. Furthermore, using Ge-rich SiGe gives access to a range of deep mid-IR wavelengths otherwise inaccessible (λ 2-20 μm). In this paper, we explore for the first time the limits of this approach by measuring the spectral loss characteristic over a broadband wavelength range spanning from λ = 5.5 μm to 8.5 μm. Three different SiGe waveguide platforms are compared, each one showing higher compactness than the preceding through the engineering of the vertical Ge profile, giving rise to different confinement characteristics to the propagating modes. A flat propagation loss characteristic of 2-3 dB/cm over the entire wavelength span is demonstrated in Ge-rich graded-index SiGe waveguides of only 6 μm thick. Also, the role of the overlap fraction of the confined optical mode with the Si-rich area at the bottom side of the epitaxial SiGe waveguide is put in perspective, revealing a lossy characteristic compared to the other designs were the optical mode is located in the Ge-rich area at the top of the waveguide uniquely. These Ge-rich graded-index SiGe waveguides may pave the way towards a new generation of photonic integrated circuits operating at deep mid-IR wavelengths.

  17. Value-Added Clinical Systems Learning Roles for Medical Students That Transform Education and Health: A Guide for Building Partnerships Between Medical Schools and Health Systems.

    Science.gov (United States)

    Gonzalo, Jed D; Lucey, Catherine; Wolpaw, Terry; Chang, Anna

    2017-05-01

    To ensure physician readiness for practice and leadership in changing health systems, an emerging three-pillar framework for undergraduate medical education integrates the biomedical and clinical sciences with health systems science, which includes population health, health care policy, and interprofessional teamwork. However, the partnerships between medical schools and health systems that are commonplace today use health systems as a substrate for learning. Educators need to transform the relationship between medical schools and health systems. One opportunity is the design of authentic workplace roles for medical students to add relevance to medical education and patient care. Based on the experiences at two U.S. medical schools, the authors describe principles and strategies for meaningful medical school-health system partnerships to engage students in value-added clinical systems learning roles. In 2013, the schools began large-scale efforts to develop novel required longitudinal, authentic health systems science curricula in classrooms and workplaces for all first-year students. In designing the new medical school-health system partnerships, the authors combined two models in an intersecting manner-Kotter's change management and Kern's curriculum development steps. Mapped to this framework, they recommend strategies for building mutually beneficial medical school-health system partnerships, including developing a shared vision and strategy and identifying learning goals and objectives; empowering broad-based action and overcoming barriers in implementation; and generating short-term wins in implementation. Applying this framework can lead to value-added clinical systems learning roles for students, meaningful medical school-health system partnerships, and a generation of future physicians prepared to lead health systems change.

  18. Improving accuracy of medication identification in an older population using a medication bottle color symbol label system.

    Science.gov (United States)

    Cardarelli, Roberto; Mann, Christopher; Fulda, Kimberly G; Balyakina, Elizabeth; Espinoza, Anna; Lurie, Sue

    2011-12-29

    The purpose of this pilot study was to evaluate and refine an adjuvant system of color-specific symbols that are added to medication bottles and to assess whether this system would increase the ability of patients 65 years of age or older in matching their medication to the indication for which it was prescribed. This study was conducted in two phases, consisting of three focus groups of patients from a family medicine clinic (n = 25) and a pre-post medication identification test in a second group of patient participants (n = 100). Results of focus group discussions were used to refine the medication label symbols according to themes and messages identified through qualitative triangulation mechanisms and data analysis techniques. A pre-post medication identification test was conducted in the second phase of the study to assess differences between standard labeling alone and the addition of the refined color-specific symbols. The pre-post test examined the impact of the added labels on participants' ability to accurately match their medication to the indication for which it was prescribed when placed in front of participants and then at a distance of two feet. Participants appreciated the addition of a visual aid on existing medication labels because it would not be necessary to learn a completely new system of labeling, and generally found the colors and symbols used in the proposed labeling system easy to understand and relevant. Concerns were raised about space constraints on medication bottles, having too much information on the bottle, and having to remember what the colors meant. Symbols and colors were modified if they were found unclear or inappropriate by focus group participants. Pre-post medication identification test results in a second set of participants demonstrated that the addition of the symbol label significantly improved the ability of participants to match their medication to the appropriate medical indication at a distance of two feet (p

  19. A cloud medication safety support system using QR code and Web services for elderly outpatients.

    Science.gov (United States)

    Tseng, Ming-Hseng; Wu, Hui-Ching

    2014-01-01

    Drug is an important part of disease treatment, but medication errors happen frequently and have significant clinical and financial consequences. The prevalence of prescription medication use among the ambulatory adult population increases with advancing age. Because of the global aging society, outpatients need to improve medication safety more than inpatients. The elderly with multiple chronic conditions face the complex task of medication management. To reduce the medication errors for the elder outpatients with chronic diseases, a cloud medication safety supporting system is designed, demonstrated and evaluated. The proposed system is composed of a three-tier architecture: the front-end tier, the mobile tier and the cloud tier. The mobile tier will host the personalized medication safety supporting application on Android platforms that provides some primary functions including reminders for medication, assistance with pill-dispensing, recording of medications, position of medications and notices of forgotten medications for elderly outpatients. Finally, the hybrid technology acceptance model is employed to understand the intention and satisfaction level of the potential users to use this mobile medication safety support application system. The result of the system acceptance testing indicates that this developed system, implementing patient-centered services, is highly accepted by the elderly. This proposed M-health system could assist elderly outpatients' homecare in preventing medication errors and improving their medication safety.

  20. Partial wave analysis of the low mass antikaon-neutral π+π- system produced in the reaction K-p→antikaon-neutral π+π-n at 3.95 and 14.3GeV/c

    International Nuclear Information System (INIS)

    Drevillon, B.; Borenstein, S.; Chaurand, B.; Gago, J.M.; Salmeron, R.A.; Borg, A.; Denegri, D.; Pons, Y.; Spiro, M.; Comber, C.; Paler, K.; Tovey, S.N.; Shah, T.P.

    1975-01-01

    A partial wave analysis of spin-parity of the (antikaon-neutral π + π - ) system in the mass range M(antikaon-neutral π + π - ) - and 1 + states is found, the unatural spin-parity accounting for more than 3/4 of the events at 3.95GeV/c and for more than half at 14.3GeV/c. Natural parity exchange is dominant at both energies. A fit of the cross sections of several states to Psub(lab)sup(-n) gives n between 1.5 and 2.0 [fr

  1. AnGel System for the diagnosis of generators in operation; Sistema AnGeL para el diagnostico de generadores en operacion

    Energy Technology Data Exchange (ETDEWEB)

    De la Torre V, H. Octavio; Ramirez N, J. Tomas; Pascacio de los S, Alberth; Reyes M, Oscar A; Carrillo C, Jaime; Iturbe F, Marlene [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico); Ponce de Leon V, Eugenio [Comision Federal de Electricidad (Mexico)

    2005-07-01

    The continuous monitoring of the electrical variables of a generator allows the knowing of the operating status of the main components of the equipment, which is helpful at the time of emitting a diagnosis of the same one. System of diagnosis for generators of operation, denominated AnGel System (acronym of Analysis of Generators in Line). The system was developed by the Management of Electrical equipment of the Instituto de Investigaciones Electricas (IIE) and implemented in the six units of generation of the Manzanillo Thermoelectric Unit. The present article includes a description of the main components and functions. The world-wide tendency in monitoring systems of the fault statistics, were key elements in defining the variable to be monitored: Partial discharges (PD), Shaft current (SC), Neutral current (NC), Tangential Magnetic (TM) flux, Voltages and currents of line (as reference to the operation point). The main processes of deterioration that are intended to be observed with each one of these variables are described with greater thoroughness in the article Sistema AnGel: Aspectos teorico-practicos para el diagnostico de generadores en operacion (AnGel System: Theoretical-practical aspects for the diagnosis of generators in operation), contained in the section of Research Activities in this same issue of the IIE bulletin. [Spanish] La monitorizacion continua de las variables electricas de un generador permite conocer el estado operativo de los principales componentes del equipo, lo que es de ayuda a la hora de emitir un diagnostico del mismo. Sistema de diagnostico para generadores de operacion, denominado Sistema AnGeL (acronimo de Analisis de Generadores en Linea). El sistema fue desarrollado por la Gerencia de Equipos Electricos del IIE e implementado en las seis unidades de generacion del Complejo Termoelectrico Manzanillo. El presente articulo incluye una descripcion de los principales componentes y funciones. La tendencia mundial en sistemas de

  2. Development of a production scale purification of Ge-68 from irradiated gallium metal

    Energy Technology Data Exchange (ETDEWEB)

    Fitzsimmons, Jonathan M.; Mausner, Leonard [Brookhaven National Laboratory, Upton, NY (United States)

    2015-05-01

    Germanium-68 (Ge-68) is produced by proton irradiation of a gallium metal target and purified by organic extraction. The Ge-68 can be used in a medical isotope generator to produce Gallium-68 (Ga-68) which can be used to radiolabel PET imaging agents. The emerging use of Ge-68 in the Ga-68 medical isotope generator has caused us to develop a new purification method for Ge-68 that does not use toxic solvents. The purpose of this work was to develop a production scale separation of Ge-68 that utilizes a leaching step to remove a bulk of the gallium metal, followed by purification with Sephadex {sup copyright} G25. Production scale (300 mCi) purification was performed with the new method. The purified Ge-68 contained the highest radioactivity concentration of Ge-68 produced at BNL; the sample meet Department of Energy specifications and the method had an excellent recovery of Ge-68.

  3. Development of 3-D Medical Image VIsualization System

    African Journals Online (AJOL)

    User

    uses standard 2-D medical imaging inputs and generates medical images of human body parts ... light wave from points on the 3-D object(s) in ... tools, and communication bandwidth cannot .... locations along the track that correspond with.

  4. Development of a medical robot system for minimally invasive surgery.

    Science.gov (United States)

    Feng, Mei; Fu, Yili; Pan, Bo; Liu, Chang

    2012-03-01

    Robot-assisted systems have been widely used in minimally invasive surgery (MIS) practice, and with them the precision and accuracy of surgical procedures can be significantly improved. Promoting the development of robot technology in MIS will improve robot performance and help in tackling problems from complex surgical procedures. A medical robot system with a new mechanism for MIS was proposed to achieve a two-dimensional (2D) remote centre of motion (RCM). An improved surgical instrument was designed to enhance manipulability and eliminate the coupling motion between the wrist and the grippers. The control subsystem adopted a master-slave control mode, upon which a new method with error compensation of repetitive feedback can be based for the inverse kinematics solution. A unique solution with less computation and higher satisfactory accuracy was also obtained. Tremor filtration and trajectory planning were also addressed with regard to the smoothness of the surgical instrument movement. The robot system was tested on pigs weighing 30-45 kg. The experimental results show that the robot can successfully complete a cholecystectomy and meet the demands of MIS. The results of the animal experiments were excellent, indicating a promising clinical application of the robot with high manipulability. Copyright © 2011 John Wiley & Sons, Ltd.

  5. Vehicle Radiation Monitoring Systems for Medical Waste Disposal - 12102

    Energy Technology Data Exchange (ETDEWEB)

    Kondrashov, Vladislav S.; Steranka, Steve A. [RadComm Systems Corp., 2931 Portland Dr., Oakville, ON L6H 5S4 (Canada)

    2012-07-01

    Hospitals often declare their waste as being 'non-radioactive'; however this material often has excessive levels of radiation caused either by an accident or lack of control. To ensure the best possible protection against the accidental receipt of radioactive materials and as a safety precaution for their employees, waste-handling companies have installed large-scale radiation portal monitors at their weigh scales or entry gates of the incinerator plant, waste transfer station, and/or landfill. Large-volume plastic scintillator-based systems can be used to monitor radiation levels at entry points to companies handling medical waste. The recent and intensive field tests together with the thousands of accumulated hours of actual real-life vehicle scanning have proven that the plastic scintillation based system is an appropriate radiation control instrument for waste management companies. The Real-Time background compensation algorithm is flexible with automatic adjustable coefficients that will response to rapidly changing environmental and weather conditions maintaining the preset alarm threshold levels. The Dose Rate correction algorithms further enhance the system's ability to meet the stringent requirements of the waste industries need for Dose Rate measurements. (authors)

  6. Accreditation of Medical Laboratories – System, Process, Benefits for Labs

    Directory of Open Access Journals (Sweden)

    Zima Tomáš

    2017-09-01

    Full Text Available One and key of the priorities in laboratory medicine is improvement of quality management system for patient safety. Quality in the health care is tightly connected to the level of excellence of the health care provided in relation to the current level of knowledge and technical development. Accreditation is an effective way to demonstrate competence of the laboratory, a tool to recognize laboratories world-wide, is linked to periodical audits, to stimulate the maintenance and improvement of the quality, which leads to high standard of services for clients (patients, health care providers, etc.. The strategic plans of IFCC and EFLM include focusing on accreditation of labs based on ISO standards and cooperation with European Accreditation and national accreditation bodies. IFCC and EFLM recognised that ISO 15189:2012 Medical laboratories – Requirements for quality and competence, encompasses all the assessment criteria specified in the policy of quality. The last version is oriented to process approach with detailed division and clearly defined requirements. The accreditation of labs improves facilitation of accurate and rapid diagnostics, efficiency of treatment and reduction of errors in the laboratory process. Accreditation is not about who the best is, but who has a system of standard procedures with aim to improve the quality and patient safety. Quality system is about people, with people and for people.

  7. Pharmacist-led admission medication reconciliation before and after the implementation of an electronic medication management system.

    Science.gov (United States)

    Sardaneh, Arwa A; Burke, Rosemary; Ritchie, Angus; McLachlan, Andrew J; Lehnbom, Elin C

    2017-05-01

    To investigate the impact of the introduction of an electronic medication management system on the proportion of patients with a recorded medication reconciliation on admission, the time from admission to when medication reconciliation was performed, and the characteristics of patients receiving this intervention pre-and post-implementation. An electronic medication management system was implemented in an Australian hospital from May to July 2015. A retrospective observational study was conducted in three wards across two phases; pre- (August 2014) and post- (August 2015) implementation. The study sample included every second patient admitted to these wards. A total of 370 patients were included, 179 pre- and 191 post-implementation. The proportion of recorded admission medication reconciliation significantly increased post-implementation in all study wards; coronary care unit (40 vs 68%, p=0.004), gastroenterology ward (39 vs 59%, p=0.015), and the neurology ward (19 vs 45%, p=0.002). The proportion of patients with recorded medication reconciliation within 24h of weekday admissions, or 48-72h of weekend admissions, increased from 47% pre- to 84% post-implementation. Admission medication reconciliation was recorded within a median of 1.0day for weekday admissions pre- and post-implementation (IQR 1.1 vs 0.2, respectively), and 3.5days (IQR 2.0) pre-implementation vs 1.5days (IQR 2.0) post-implementation for weekend admissions. Overall, across both phases pre-and post-implementation, admission medication reconciliation was recorded for patients who were significantly older (median 77 and 71 years, p<0.001), had a higher number of preadmission medications (median 6.5 and 5.0 medicines, p=0.001), and had a longer hospital stay (median 6.5 and 5.1days, p=0.003). A significantly higher proportion of patients with recorded medication reconciliation in the pre-implementation phase experienced polypharmacy (61%, p=0.002), hyperpolypharmacy (15%, p=0.001), and used a high

  8. The health physics system at the Bonn 2.3 GeV electron synchrotron with the ELSA storage ring

    International Nuclear Information System (INIS)

    Doeing, R.; Giese, R.; Husmann, D.; Ewen, K.

    1992-01-01

    The health physics system installed and operated for providing radiological safety to the personnal consists of an interlock system monitoring access to the controlled areas, alarm and signaling systems, and a radiation measuring equipment for the controlled and monitored areas. (DG) [de

  9. The π-η and π-η' systems in exclusive 190 GeV π-p reactions at COMPASS (CERN)

    International Nuclear Information System (INIS)

    Schlueter, Tobias

    2012-01-01

    We have studied the reactions π - p→π - ηp and π - p→π - η'p at momentum transfers to the target in the range 0.1 GeV 2 <-t<1 GeV 2 . Initially, this was motivated by previous claims of a spin-exotic resonance in the P-wave of these reactions. We have selected and analyzed data taken by COMPASS in 2008. Our analysis employed the technique of partial-wave analysis, which we described in detail. We compared the results between two different implementations. As a new component of the apparatus, we developed a 2m x 2m veto detector. We found significant P-wave intensities in both final states. We also found known resonances and further structure in the D + and G + waves. Due to the higher bombarding energy compared to previous studies of these channels, and due to the large acceptance of the COMPASS experiment, we could follow the partial-wave decomposition to masses beyond 2 GeV. We found that at high masses rapidity-gap kinematics arise, where a Regge description of the data is more economic, and correspondingly extracted additional partial-waves in the fit. We found that the waves D + and G + show very similar behavior between the π - η and π - η' systems, once phase-space factors are taken into account. This similarity is not given for the P + wave which is enhanced in the π - η' system compared to the π - η system, even before taking into account the larger π - η phase-space. The phase motion of the P + -wave relative to the D + -wave also shows different behavior in the two systems, though the phase-difference agrees on the π - η' threshold. Resonance parameters, including relative branching fractions, of the a 2 (1320) (in the D + wave) and the a 4 (2040) (in the G + wave) are found to be in agreement between both channels and with other measurements (where available). A resonant interpretation of the P + -wave contributions in the vein of previous analyses was possible by including large background terms and by adding

  10. Collaborative Systems Biology Projects for the Military Medical Community.

    Science.gov (United States)

    Zalatoris, Jeffrey J; Scheerer, Julia B; Lebeda, Frank J

    2017-09-01

    This pilot study was conducted to examine, for the first time, the ongoing systems biology research and development projects within the laboratories and centers of the U.S. Army Medical Research and Materiel Command (USAMRMC). The analysis has provided an understanding of the breadth of systems biology activities, resources, and collaborations across all USAMRMC subordinate laboratories. The Systems Biology Collaboration Center at USAMRMC issued a survey regarding systems biology research projects to the eight U.S.-based USAMRMC laboratories and centers in August 2016. This survey included a data call worksheet to gather self-identified project and programmatic information. The general topics focused on the investigators and their projects, on the project's research areas, on omics and other large data types being collected and stored, on the analytical or computational tools being used, and on identifying intramural (i.e., USAMRMC) and extramural collaborations. Among seven of the eight laboratories, 62 unique systems biology studies were funded and active during the final quarter of fiscal year 2016. Of 29 preselected medical Research Task Areas, 20 were associated with these studies, some of which were applicable to two or more Research Task Areas. Overall, studies were categorized among six general types of objectives: biological mechanisms of disease, risk of/susceptibility to injury or disease, innate mechanisms of healing, diagnostic and prognostic biomarkers, and host/patient responses to vaccines, and therapeutic strategies including host responses to therapies. We identified eight types of omics studies and four types of study subjects. Studies were categorized on a scale of increasing complexity from single study subject/single omics technology studies (23/62) to studies integrating results across two study subject types and two or more omics technologies (13/62). Investigators at seven USAMRMC laboratories had collaborations with systems biology experts

  11. Optical transitions in Ge/SiGe multiple quantum wells with Ge-rich barriers

    Science.gov (United States)

    Bonfanti, M.; Grilli, E.; Guzzi, M.; Virgilio, M.; Grosso, G.; Chrastina, D.; Isella, G.; von Känel, H.; Neels, A.

    2008-07-01

    Direct-gap and indirect-gap transitions in strain-compensated Ge/SiGe multiple quantum wells with Ge-rich SiGe barriers have been studied by optical transmission spectroscopy and photoluminescence experiments. An sp3d5s∗ tight-binding model has been adopted to interpret the experimental results. Photoluminescence spectra and their comparison with theoretical calculations prove the existence of type-I band alignment in compressively strained Ge quantum wells grown on relaxed Ge-rich SiGe buffers. The high quality of the transmission spectra opens up other perspectives for application of these structures in near-infrared optical modulators.

  12. Quantum confinement effects on the thermoelectric figure of merit in Si/Si{sub 1{minus}x}Ge{sub x} system

    Energy Technology Data Exchange (ETDEWEB)

    Sun, X; Dresselhaus, M S; Wang, K L; Tanner, M O

    1997-07-01

    The Si/Si{sub 1{minus}x}Ge{sub x} quantum well system is attractive for high temperature thermoelectric applications and for demonstration of proof-of-principle for enhanced thermoelectric figure of merit Z, since the interfaces and carrier densities can be well controlled in this system. The authors report here theoretical calculations for Z in this system, and results from theoretical modeling of quantum confinement effects in the presence of {delta}-doping within the barrier layers. The {delta}-doping layers are introduced by growing very thin layers of wide band gap materials within the barrier layers in order to increase the effective barrier height within the barriers and thereby reduce the barrier width necessary for the quantum confinement of carriers within the quantum well. The overall figure of merit is thereby enhanced due to the reduced barrier width and hence reduced thermal conductivity, {kappa}. The {delta}-doping should further reduce {kappa} in the barriers by introducing phonon scattering centers within the barrier region. The temperature dependence of Z for Si quantum wells is also discussed.

  13. Evaluation of a hybrid paper-electronic medication management system at a residential aged care facility.

    Science.gov (United States)

    Elliott, Rohan A; Lee, Cik Yin; Hussainy, Safeera Y

    2016-06-01

    Objectives The aims of the study were to investigate discrepancies between general practitioners' paper medication orders and pharmacy-prepared electronic medication administration charts, back-up paper charts and dose-administration aids, as well as delays between prescribing, charting and administration, at a 90-bed residential aged care facility that used a hybrid paper-electronic medication management system. Methods A cross-sectional audit of medication orders, medication charts and dose-administration aids was performed to identify discrepancies. In addition, a retrospective audit was performed of delays between prescribing and availability of an updated electronic medication administration chart. Medication administration records were reviewed retrospectively to determine whether discrepancies and delays led to medication administration errors. Results Medication records for 88 residents (mean age 86 years) were audited. Residents were prescribed a median of eight regular medicines (interquartile range 5-12). One hundred and twenty-five discrepancies were identified. Forty-seven discrepancies, affecting 21 (24%) residents, led to a medication administration error. The most common discrepancies were medicine omission (44.0%) and extra medicine (19.2%). Delays from when medicines were prescribed to when they appeared on the electronic medication administration chart ranged from 18min to 98h. On nine occasions (for 10% of residents) the delay contributed to missed doses, usually antibiotics. Conclusion Medication discrepancies and delays were common. Improved systems for managing medication orders and charts are needed. What is known about the topic? Hybrid paper-electronic medication management systems, in which prescribers' orders are transcribed into an electronic system by pharmacy technicians and pharmacists to create medication administration charts, are increasingly replacing paper-based medication management systems in Australian residential aged care

  14. Integration of SNOMED CT into the OpenMRS electronic medical record system framework

    CSIR Research Space (South Africa)

    Gerber, A

    2008-11-01

    Full Text Available Integrating a mechanism to store, retrieve and use clinical data with a system to manage medical records enables better utilisation of medical data and improved healthcare. This poster introduces a research project that aims to extend Open...

  15. A SWOT Analysis of the Various Backup Scenarios Used in Electronic Medical Record Systems.

    Science.gov (United States)

    Seo, Hwa Jeong; Kim, Hye Hyeon; Kim, Ju Han

    2011-09-01

    Electronic medical records (EMRs) are increasingly being used by health care services. Currently, if an EMR shutdown occurs, even for a moment, patient safety and care can be seriously impacted. Our goal was to determine the methodology needed to develop an effective and reliable EMR backup system. Our "independent backup system by medical organizations" paradigm implies that individual medical organizations develop their own EMR backup systems within their organizations. A "personal independent backup system" is defined as an individual privately managing his/her own medical records, whereas in a "central backup system by the government" the government controls all the data. A "central backup system by private enterprises" implies that individual companies retain control over their own data. A "cooperative backup system among medical organizations" refers to a networked system established through mutual agreement. The "backup system based on mutual trust between an individual and an organization" means that the medical information backup system at the organizational level is established through mutual trust. Through the use of SWOT analysis it can be shown that cooperative backup among medical organizations is possible to be established through a network composed of various medical agencies and that it can be managed systematically. An owner of medical information only grants data access to the specific person who gave the authorization for backup based on the mutual trust between an individual and an organization. By employing SWOT analysis, we concluded that a linkage among medical organizations or between an individual and an organization can provide an efficient backup system.

  16. Addition of Mn to Ge quantum dot surfaces—interaction with the Ge QD {105} facet and the Ge(001) wetting layer

    International Nuclear Information System (INIS)

    Nolph, C A; Kassim, J K; Floro, J A; Reinke, P

    2013-01-01

    The interaction of Mn with Ge quantum dots (QD), which are bounded by {105} facets, and the strained Ge wetting layer (WL), terminated by a (001) surface, is investigated with scanning tunneling microscopy (STM). These surfaces constitute the growth surfaces in the growth of Mn-doped QDs. Mn is deposited on the Ge QD and WL surface in sub-monolayer concentrations, and subsequently annealed up to a temperature of 400 ° C. The changes in bonding and surface topography are measured with STM during the annealing process. Mn forms flat islands on the Ge{105} facet, whose shape and position are guided by the rebonded step reconstruction of the facet. Voltage-dependent STM images reflect the Mn-island interaction with the empty and filled states of the Ge{105} reconstruction. Scanning tunneling spectra (STS) of the Ge{105} facet and as-deposited Mn-islands show a bandgap of 0.8 eV, and the Mn-island spectra are characterized by an additional empty state at about 1.4 eV. A statistical analysis of Mn-island shape and position on the QD yields a slight preference for edge positions, whereas the QD strain field does not impact Mn-island position. However, the formation of ultra-small Mn-clusters dominates on the Ge(001) WL, which is in contrast to Mn interaction with unstrained Ge(001) surfaces. Annealing to T 5 Ge 3 from a mass balance analysis. This reaction is accompanied by the disappearance of the original Mn-surface structures and de-wetting of Mn is complete. This study unravels the details of Mn–Ge interactions, and demonstrates the role of surface diffusion as a determinant in the growth of Mn-doped Ge materials. Surface doping of Ge-nanostructures at lower temperatures could provide a pathway to control magnetism in the Mn–Ge system. (paper)

  17. Structure and Chemical Bonding of the Li-Doped Polar Intermetallic RE2In1−xLixGe2 (RE = La, Nd, Sm, Gd; x = 0.13, 0.28, 0.43, 0.53 System

    Directory of Open Access Journals (Sweden)

    Junsu Lee

    2018-03-01

    Full Text Available Four polar intermetallic compounds belonging to the RE2In1−xLixGe2 (RE = La, Nd, Sm, Gd; x = 0.13(1, 0.28(1, 0.43(1, 0.53(1 system have been synthesized by the traditional solid-state reaction method, and their crystal structures have been characterized by single-crystal X-ray diffraction (SXRD analyses. The isotypic crystal structures of four title compounds adopt the Mo2FeB2-type structure having the tetragonal space group P4/mbm (Z = 2, Pearson code tP40 with three crystallographically independent atomic sites and can be simply described as a pile of the identical 2-dimensioanl (2D RE2In1-xLixGe2 slabs stacked along the c-axis direction. The substituting Li atom shows a particular site preference for replacing In at the Wyckoff 2a site rather than Ge at the Wyckoff 4g in this crystal structure. As the size of a used rare-earth metal decreases from La3+ to Gd3+ throughout the title system, the Ge-Ge and Ge-In/Li bond distances, both of which consist of the 2D anionic Ge2(In/Li layer, gradually decrease resulting in the reduction of a unit cell volume. A series of theoretical investigations has been performed using a hypothetical structure model Gd2In0.5Li0.5Ge2 by tight-binding linear muffin-tin orbital (TB-LMTO method. The resultant densities of states (DOS value at the Fermi level (EF suggests a metallic conductivity for this particular composition, and this calculation result is in a good agreement with the formal charge distribution assigning two extra valence electrons for a metal-metal bond in the conduction band. The thorough analyses of six crystal orbital Hamilton population (COHP curves representing various interatomic interactions and an electron localization function (ELF diagram indicating the locations of paired-electron densities are also provided in this article.

  18. Systems-based practice in graduate medical education: systems thinking as the missing foundational construct.

    Science.gov (United States)

    Colbert, Colleen Y; Ogden, Paul E; Ownby, Allison R; Bowe, Constance

    2011-04-01

    Since 2001, residencies have struggled with teaching and assessing systems-based practice (SBP). One major obstacle may be that the competency alone is not sufficient to support assessment. We believe the foundational construct underlying SBP is systems thinking, absent from the current Accreditation Council for Graduate Medical Education competency language. Systems thinking is defined as the ability to analyze systems as a whole. The purpose of this article is to describe psychometric issues that constrain assessment of SBP and elucidate the role of systems thinking in teaching and assessing SBP. Residency programs should incorporate systems thinking models into their curricula. Trainees should be taught to understand systems at an abstract level, in order to analyze their own healthcare systems, and participate in quality and patient safety activities. We suggest that a developmental trajectory for systems thinking be developed, similar to the model described by Dreyfus and Dreyfus.

  19. Physician Acceptance of a Computerized Outpatient Medication System in a Teaching Hospital Group Practice

    OpenAIRE

    Blish, Christi; Proctor, Rita; Fletcher, Suzanne W.; O'Malley, Michael

    1983-01-01

    As part of a new automated ambulatory medical record, a computerized outpatient medication system was developed for a teaching hospital general medicine group practice. Seven months after its implementation, the system was evaluated to determine physician acceptance and approval. Practice physicians were surveyed, and 94% of the respondents approved of the system. Over 90% thought that the computerized system had improved the completeness and accuracy of medication information as well as thei...

  20. Feasibility Study of the PS Injection for 2 GeV LIU Beams with an Upgraded KFA-45 Injection Kicker System Operating in Short Circuit Mode

    CERN Document Server

    Kramer, Thomas; Borburgh, Jan; Ducimetière, Laurent; Feliciano, Luis; Ferrero Colomo, Alvaro; Goddard, Brennan; Sermeus, Luc

    2016-01-01

    Under the scope of the LIU project the CERN PS Booster to PS beam transfer will be modified to match the requirements for the future 2 GeV beams. This paper describes the evaluation of the proposed upgrade of the PS injection kicker. Different schemes of an injection for LIU beams into the PS have been outlined in the past already under the aspect of individual transfer kicker rise and fall time performances. Homogeneous rise and fall time requirements in the whole PSB to PS transfer chain have been established which allowed to consider an upgrade option of the present injection kicker system operated in short circuit mode. The challenging pulse quality constraints require an improvement of the flat top and post pulse ripples. Both operation modes, terminated and short circuit mode are analysed and analogue circuit simulations for the present and upgraded system are outlined. Recent measurements on the installed kickers are presented and analysed together with the simulation data. First measurements verifying...

  1. Evaluation of the medical records system in an upcoming teaching hospital-a project for improvisation.

    Science.gov (United States)

    Kumar, B Deepak; Kumari, C M Vinaya; Sharada, M S; Mangala, M S

    2012-08-01

    The medical records system of an upcoming teaching hospital in a developing nation was evaluated for its accessibility, completeness, physician satisfaction, presence of any lacunae, suggestion of necessary steps for improvisation and to emphasize the importance of Medical records system in education and research work. The salient aspects of the medical records department were evaluated based on a questionnaire which was evaluated by a team of 40 participants-30 doctors, 5 personnel from Medical Records Department and 5 from staff of Hospital administration. Most of the physicians (65%) were partly satisfied with the existing medical record system. 92.5% were of the opinion that upgradation of the present system is necessary. The need of the hour in the present teaching hospital is the implementation of a hospital-wide patient registration and medical records re-engineering process in the form of electronic medical records system and regular review by the audit commission.

  2. Intelligence system based classification approach for medical disease diagnosis

    Science.gov (United States)

    Sagir, Abdu Masanawa; Sathasivam, Saratha

    2017-08-01

    The prediction of breast cancer in women who have no signs or symptoms of the disease as well as survivability after undergone certain surgery has been a challenging problem for medical researchers. The decision about presence or absence of diseases depends on the physician's intuition, experience and skill for comparing current indicators with previous one than on knowledge rich data hidden in a database. This measure is a very crucial and challenging task. The goal is to predict patient condition by using an adaptive neuro fuzzy inference system (ANFIS) pre-processed by grid partitioning. To achieve an accurate diagnosis at this complex stage of symptom analysis, the physician may need efficient diagnosis system. A framework describes methodology for designing and evaluation of classification performances of two discrete ANFIS systems of hybrid learning algorithms least square estimates with Modified Levenberg-Marquardt and Gradient descent algorithms that can be used by physicians to accelerate diagnosis process. The proposed method's performance was evaluated based on training and test datasets with mammographic mass and Haberman's survival Datasets obtained from benchmarked datasets of University of California at Irvine's (UCI) machine learning repository. The robustness of the performance measuring total accuracy, sensitivity and specificity is examined. In comparison, the proposed method achieves superior performance when compared to conventional ANFIS based gradient descent algorithm and some related existing methods. The software used for the implementation is MATLAB R2014a (version 8.3) and executed in PC Intel Pentium IV E7400 processor with 2.80 GHz speed and 2.0 GB of RAM.

  3. Use of web based systems to support postgraduate medical education.

    Science.gov (United States)

    Tochel, C; Beggs, K; Haig, A; Roberts, J; Scott, H; Walker, K; Watson, M

    2011-12-01

    BACKGROUND To meet the demands of delivering the Foundation programme across a geographically diverse country, two web based systems (ePortfolio and eLearning) were developed to promote accessibility to training material and assessment tools on standardised platforms. This study evaluated the use of both tools throughout an entire academic year. METHODS All Scottish Foundation trainees' online learning and assessment data in 2007/08 were analysed, providing a national breakdown of post specialty, completion rates of mandatory assessments (including summary analysis of anonymised scores), and trainees' use of non-mandatory learning tools. Independent verification of competence data was sought from Deaneries. RESULTS There were high levels of engagement with both the ePortfolio (75-97% assessment completion) and eLearning systems (89-98% induction course completion), and the majority of trainees completed all required elements. There was extensive use of ePortfolio beyond mandatory levels for recording of learning events, including almost 20 000 personal learning records submitted by second year trainees. There was evidence that ePortfolio was used to record achievement of clinical competence rather than to track improvements towards competence (median workplace based assessment scores were 'high' or 'very high'). Online learning modules received positive feedback and its flexible format suited the trainees' working environment. External verification of formal assessment data revealed good correlation with locally stored outcomes, both indicating approximately 99% programme completion rates. CONCLUSIONS Core components of the Foundation programme have been delivered successfully to thousands of trainees across Scotland using web based systems to deliver and support education and assessment. There is great potential for further exploration of this carefully managed, rich dataset at individual, regional, and national levels to inform the future of medical education.

  4. A novel AIDS/HIV intelligent medical consulting system based on expert systems.

    Science.gov (United States)

    Ebrahimi, Alireza Pour; Toloui Ashlaghi, Abbas; Mahdavy Rad, Maryam

    2013-01-01

    The purpose of this paper is to propose a novel intelligent model for AIDS/HIV data based on expert system and using it for developing an intelligent medical consulting system for AIDS/HIV. In this descriptive research, 752 frequently asked questions (FAQs) about AIDS/HIV are gathered from numerous websites about this disease. To perform the data mining and extracting the intelligent model, the 6 stages of Crisp method has been completed for FAQs. The 6 stages include: Business understanding, data understanding, data preparation, modelling, evaluation and deployment. C5.0 Tree classification algorithm is used for modelling. Also, rational unified process (RUP) is used to develop the web-based medical consulting software. Stages of RUP are as follows: Inception, elaboration, construction and transition. The intelligent developed model has been used in the infrastructure of the software and based on client's inquiry and keywords related FAQs are displayed to the client, according to the rank. FAQs' ranks are gradually determined considering clients reading it. Based on displayed FAQs, test and entertainment links are also displayed. The accuracy of the AIDS/HIV intelligent web-based medical consulting system is estimated to be 78.76%. AIDS/HIV medical consulting systems have been developed using intelligent infrastructure. Being equipped with an intelligent model, providing consulting services on systematic textual data and providing side services based on client's activities causes the implemented system to be unique. The research has been approved by Iranian Ministry of Health and Medical Education for being practical.

  5. Medical isotope identification with large mobile detection systems

    Science.gov (United States)

    Mukhopadhyay, Sanjoy; Maurer, Richard

    2012-10-01

    The Remote Sensing laboratory (RSL) of National Security Technologies Inc. has built an array of large (5.08 - cm x 10.16 - cm x 40.6 - cm) thallium doped sodium iodide (NaI: Tl) scintillators to locate and screen gamma-ray emitting radioisotopes that are of interests to radiological emergency responders [1]. These vehicle mounted detectors provide the operators with rapid, simple, specific information for radiological threat assessment. Applications include large area inspection, customs inspection, border protection, emergency response, and monitoring of radiological facilities. These RSL mobile units are currently being upgraded to meet the Defense Threat Reduction Agency mission requirements for a next-generation system capable of detecting and identifying nuclear threat materials. One of the challenging problems faced by these gamma-ray detectors is the unambiguous identification of medical isotopes like 131I (364.49 keV [81.7%], 636.99 keV [7.17%]), 99Tcm (140.51 keV [89.1%]) and 67Ga (184.6 keV [19.7%], 300.2 [16.0%], 393.5 [4.5%] that are used in radionuclide therapy and often have overlapping gamma-ray energy regions of interest (ROI). The problem is made worse by short (about 5 seconds) acquisition time of the spectral data necessary for dynamic mobile detectors. This article describes attempts to identify medical isotopes from data collected from this mobile detection system in a short period of time (not exceeding 5 secs) and a large standoff distance (typically 10 meters) The mobile units offer identification capabilities that are based on hardware auto stabilization of the amplifier gain. The 1461 keV gamma-energy line from 40K is tracked. It uses gamma-ray energy windowing along with embedded mobile Gamma Detector Response and Analysis Software (GADRAS) [2] simultaneously to deconvolve any overlapping gamma-energy ROIs. These high sensitivity detectors are capable of resolving complex masking scenarios and exceed all ANSI N42.34 (2006) requirements

  6. Towards an interactive medical system by augmented reality

    OpenAIRE

    Khawla Ben Abderrahim; Mohamed Kallel; M.S. Bouhlel

    2013-01-01

    Augmented reality is a computer field that progresses rapidly. Its principle is to mix the real world and the virtual world. Many applications already use augmented reality, particularly the medical field. Medical image allows doctors to make diagnosis of the patient. This diagnosis allows him to make the best decision without committing professional mistakes that can cause problems. Hence the idea of integrating augmented reality with medical image analysis to help the doctor to make the bes...

  7. The urban transition and the evolution of the medical care delivery system in America.

    Science.gov (United States)

    Knox, P L; Bohland, J; Shumsky, N L

    1983-01-01

    This essay traces the evolution of the American urban medical care delivery system and examines the implications in terms of social and spatial variations in accessibility to medical care. It is suggested that the foundations of the present medical care delivery system were laid during the urban transformation which took place in the latter part of the nineteenth century, when changes in the division of labor, specialization, the role of the family, urban transportation technology and attitudes to social protectionism interacted with changes in science, medical technology and professional organization to produce radical changes in both the settings used to provide medical care and their relative accessibility to different sub-groups of the population. The medical care delivery system is thus interpreted largely as a product of the overall dynamic of urbanization rather than of scientific discovery, medical technology and the influence of key medical practitioners and professional organizations.

  8. Facilitating medical information search using Google Glass connected to a content-based medical image retrieval system.

    Science.gov (United States)

    Widmer, Antoine; Schaer, Roger; Markonis, Dimitrios; Muller, Henning

    2014-01-01

    Wearable computing devices are starting to change the way users interact with computers and the Internet. Among them, Google Glass includes a small screen located in front of the right eye, a camera filming in front of the user and a small computing unit. Google Glass has the advantage to provide online services while allowing the user to perform tasks with his/her hands. These augmented glasses uncover many useful applications, also in the medical domain. For example, Google Glass can easily provide video conference between medical doctors to discuss a live case. Using these glasses can also facilitate medical information search by allowing the access of a large amount of annotated medical cases during a consultation in a non-disruptive fashion for medical staff. In this paper, we developed a Google Glass application able to take a photo and send it to a medical image retrieval system along with keywords in order to retrieve similar cases. As a preliminary assessment of the usability of the application, we tested the application under three conditions (images of the skin; printed CT scans and MRI images; and CT and MRI images acquired directly from an LCD screen) to explore whether using Google Glass affects the accuracy of the results returned by the medical image retrieval system. The preliminary results show that despite minor problems due to the relative stability of the Google Glass, images can be sent to and processed by the medical image retrieval system and similar images are returned to the user, potentially helping in the decision making process.

  9. [Research of regional medical consumables reagent logistics system in the modern hospital].

    Science.gov (United States)

    Wu, Jingjiong; Zhang, Yanwen; Luo, Xiaochen; Zhang, Qing; Zhu, Jianxin

    2013-09-01

    To explore the modern hospital and regional medical consumable reagents logistics system management. The characteristics of regional logistics, through cooperation between medical institutions within the region, and organize a wide range of special logistics activities, to make reasonable of the regional medical consumable reagents logistics. To set the regional management system, dynamic management systems, supply chain information management system, after-sales service system and assessment system. By the research of existing medical market and medical resources, to establish the regional medical supplies reagents directory and the initial data. The emphasis is centralized dispatch of medical supplies reagents, to introduce qualified logistics company for dispatching, to improve the modern hospital management efficiency, to costs down. Regional medical center and regional community health service centers constitute a regional logistics network, the introduction of medical consumable reagents logistics services, fully embodies integrity level, relevance, purpose, environmental adaptability of characteristics by the medical consumable reagents regional logistics distribution. Modern logistics distribution systems can increase the area of medical consumables reagent management efficiency and reduce costs.

  10. Improving the growth of Ge/Si islands by modulating the spacing between screen and accelerator grids in ion beam sputtering deposition system

    International Nuclear Information System (INIS)

    Yang, Jie; Zhao, Bo; Wang, Chong; Qiu, Feng; Wang, Rongfei; Yang, Yu

    2016-01-01

    Highlights: • Ge islands were prepared by ion beam sputtering with different grid-to-grid gaps. • Ge islands with larger sizes and low density are observed in 1-mm-spaced samples. • The island growth was determined by sputter energy and the quality of Si buffer. • The crystalline volume fraction of buffer must be higher than 72% to grow islands. - Abstract: Ge islands were fabricated on Si buffer layer by ion beam sputtering deposition with a spacing between the screen and accelerator grids of either 1 mm or 2 mm. The Si buffer layer exhibits mixed-phase microcrystallinity for samples grown with 1 mm spacing and crystallinity for those with 2 mm spacing. Ge islands are larger and less dense than those grown on the crystalline buffer because of the selective growth mechanism on the microcrystalline buffer. Moreover, the nucleation site of Ge islands formed on the crystalline Si buffer is random. Ge islands grown at different grid-to-grid gaps are characterized by two key factors, namely, divergence half angle of ion beam and crystallinity of buffer layer. High grid-to-grid spacing results in small divergence half angle, thereby enhancing the sputtering energy and redistribution of sputtered atoms. The crystalline volume fraction of the microcrystalline Si buffer was obtained based on the integrated intensity ratio of Raman peaks. The islands show decreased density with decreasing crystalline volume fraction and are difficult to observe at crystalline volume fractions lower than 72%.

  11. Improving the growth of Ge/Si islands by modulating the spacing between screen and accelerator grids in ion beam sputtering deposition system

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Jie; Zhao, Bo [Institute of Optoelectronic Information Materials, School of Materials Science and Engineering, Yunnan University, Kunming 650091 (China); Yunnan Key Laboratory for Micro/Nano Materials and Technology, Yunnan University, Kunming 650091 (China); Wang, Chong, E-mail: cwang@mail.sitp.ac.cn [Institute of Optoelectronic Information Materials, School of Materials Science and Engineering, Yunnan University, Kunming 650091 (China); Yunnan Key Laboratory for Micro/Nano Materials and Technology, Yunnan University, Kunming 650091 (China); Qiu, Feng; Wang, Rongfei [Institute of Optoelectronic Information Materials, School of Materials Science and Engineering, Yunnan University, Kunming 650091 (China); Yunnan Key Laboratory for Micro/Nano Materials and Technology, Yunnan University, Kunming 650091 (China); Yang, Yu, E-mail: yuyang@ynu.edu.cn [Institute of Optoelectronic Information Materials, School of Materials Science and Engineering, Yunnan University, Kunming 650091 (China); Yunnan Key Laboratory for Micro/Nano Materials and Technology, Yunnan University, Kunming 650091 (China)

    2016-11-15

    Highlights: • Ge islands were prepared by ion beam sputtering with different grid-to-grid gaps. • Ge islands with larger sizes and low density are observed in 1-mm-spaced samples. • The island growth was determined by sputter energy and the quality of Si buffer. • The crystalline volume fraction of buffer must be higher than 72% to grow islands. - Abstract: Ge islands were fabricated on Si buffer layer by ion beam sputtering deposition with a spacing between the screen and accelerator grids of either 1 mm or 2 mm. The Si buffer layer exhibits mixed-phase microcrystallinity for samples grown with 1 mm spacing and crystallinity for those with 2 mm spacing. Ge islands are larger and less dense than those grown on the crystalline buffer because of the selective growth mechanism on the microcrystalline buffer. Moreover, the nucleation site of Ge islands formed on the crystalline Si buffer is random. Ge islands grown at different grid-to-grid gaps are characterized by two key factors, namely, divergence half angle of ion beam and crystallinity of buffer layer. High grid-to-grid spacing results in small divergence half angle, thereby enhancing the sputtering energy and redistribution of sputtered atoms. The crystalline volume fraction of the microcrystalline Si buffer was obtained based on the integrated intensity ratio of Raman peaks. The islands show decreased density with decreasing crystalline volume fraction and are difficult to observe at crystalline volume fractions lower than 72%.

  12. [Big data, medical language and biomedical terminology systems].

    Science.gov (United States)

    Schulz, Stefan; López-García, Pablo

    2015-08-01

    A variety of rich terminology systems, such as thesauri, classifications, nomenclatures and ontologies support information and knowledge processing in health care and biomedical research. Nevertheless, human language, manifested as individually written texts, persists as the primary carrier of information, in the description of disease courses or treatment episodes in electronic medical records, and in the description of biomedical research in scientific publications. In the context of the discussion about big data in biomedicine, we hypothesize that the abstraction of the individuality of natural language utterances into structured and semantically normalized information facilitates the use of statistical data analytics to distil new knowledge out of textual data from biomedical research and clinical routine. Computerized human language technologies are constantly evolving and are increasingly ready to annotate narratives with codes from biomedical terminology. However, this depends heavily on linguistic and terminological resources. The creation and maintenance of such resources is labor-intensive. Nevertheless, it is sensible to assume that big data methods can be used to support this process. Examples include the learning of hierarchical relationships, the grouping of synonymous terms into concepts and the disambiguation of homonyms. Although clear evidence is still lacking, the combination of natural language technologies, semantic resources, and big data analytics is promising.

  13. Energy levels of germanium, Ge I through Ge XXXII

    International Nuclear Information System (INIS)

    Sugar, J.; Musgrove, A.

    1993-01-01

    Atomic energy levels of germanium have been compiled for all stages of ionization for which experimental data are available. No data have yet been published for Ge VIII through Ge XIII and Ge XXXII. Very accurate calculated values are compiled for Ge XXXI and XXXII. Experimental g-factors and leading percentages from calculated eigenvectors of levels are given. A value for the ionization energy, either experimental when available or theoretical, is included for the neutral atom and each ion. section

  14. Career intentions of medical students in the setting of Nepal's rapidly expanding private medical education system.

    Science.gov (United States)

    Huntington, Ian; Shrestha, Suvash; Reich, Nicholas G; Hagopian, Amy

    2012-08-01

    The number of medical students trained in Nepal each year has increased nearly fifty-fold in the last 15 years, primarily through the creation of private medical schools. It is unknown where this expanding cohort of new physicians will ultimately practice. We distributed an anonymous survey to students in their last 2 years of medical school at four medical schools in Nepal to examine two dimensions of career intention: the intention to practice in Nepal and the intention to practice in rural areas. Eighty-five per cent of the eligible study population participated, for a total of 469 medical students. Of these, 88% thought it was likely they would practice in Nepal and 88% thought it likely they would practice in urban areas. Those students who indicated a greater likelihood of practicing abroad came from families with higher incomes, were more likely to think earning a good salary was very important to their decision to become a physician, and were less likely to think they could earn a good salary in Nepal. Students whose tuition was paid by the government were no more likely to indicate an intention to practice in Nepal than students paying their own tuition at private medical schools. Students who indicated a greater likelihood of practicing in rural areas were more likely to be male, to have gone to a government secondary school, to have been born in a village, or to have received a scholarship from the Ministry of Education that requires rural service. Based on our findings, we suggest the following policy changes: (1) medical schools consider selecting for students from rural backgrounds or government secondary schools who are more likely to intend to practice in rural areas, and (2) increase the number of post-graduate positions--weighted toward rural health needs--to retain students in Nepal.

  15. Equipping medical graduates to address health systems challenges ...

    African Journals Online (AJOL)

    Methods: We defined HSR and strengthening competencies for medical graduates through a literature review and expert consultations. Learning outcomes in terms of knowledge, skill or attitude in the 64 module guides of the curriculum were compared with the competencies required. A survey of recent medical graduates ...

  16. Factors affecting the utilisation of electronic medical records system ...

    African Journals Online (AJOL)

    Malawi Medical Journal 29 (3): September 2017. Electronic medical ... care, as they enable storage of large amounts of data and ... EMRs. This study assessed factors that affect the use of EMRs in Malawi, particularly at Queen Elizabeth and Kamuzu Central ..... paperless hospitals in Norway : A socio-technical perspective.

  17. Formation of multinucleon systems and nuclei with mass numbers of 6 and 7 in 16Op interactions at a momentum of 3.25 GeV/c per nucleon

    International Nuclear Information System (INIS)

    Olimov, K.; Kurbanov, A.; Lutpullaev, S. L.; Olimov, Kh. K.; Petrov, V. I.; Yuldashev, A. A.; Glagolev, V. V.; Sherkulov, U. D.

    2009-01-01

    The results of a comparative analysis of the multiplicities of singly and doubly charged accompanying particles in the channels involving the production of six- and seven-nucleon systems in 16 Op collisions at a momentum of 3.25 GeV/c per nucleon are reported. Cross sections for the yield of multinucleon systems and mean multiplicities of accompanying particles are found. The experimental data are compared with the predictions of the cascade-fragmentation-evaporation model.

  18. HP Ge planar detectors

    International Nuclear Information System (INIS)

    Gornov, M.G.; Gurov, Yu.B.; Soldatov, A.M.; Osipenko, B.P.; Yurkowski, J.; Podkopaev, O.I.

    1989-01-01

    Parameters of planar detectors manufactured of HP Ge are presented. The possibilities to use multilayer spectrometers on the base of such semiconductor detectors for nuclear physics experiments are discussed. It is shown that the obtained detectors including high square ones have spectrometrical characteristics close to limiting possible values. 9 refs.; 3 figs.; 1 tab

  19. Medical tourism's impact for health systems: A study from three Asian countries

    OpenAIRE

    Ala`a Nimer AbuKhalifeh; Erwin Martinez Faller

    2015-01-01

    Medical tourism is a growing phenomenon with policy implications for health systems, particularly of destination countries. Private actors and governments in Southeast Asia are promoting the medical tourist industry, but the potential impact on health systems, particularly in terms of equity in access and availability for local consumers, is unclear. This article presents a conceptual framework that outlines the policy implications of medical tourism’s growth for health systems, illustration ...

  20. High-field magnetostriction in CeNiSn{sub 1-x}Ge{sub x} (0<=x<=1) strongly correlated systems

    Energy Technology Data Exchange (ETDEWEB)

    Moral, A. del, E-mail: delmoral@unizar.e [Laboratorio de Magnetismo de Solidos, Departamento de Fisica de Materia Condensada and ICMA, Universidad de Zaragoza and CSIC, 50009 Zaragoza (Spain); Fuente, C. de la [Laboratorio de Magnetismo de Solidos, Departamento de Fisica de Materia Condensada and ICMA, Universidad de Zaragoza and CSIC, 50009 Zaragoza (Spain)

    2010-05-15

    Magnetization (down to 1.8 K and up to 9 T) and magnetostriction (down to 4.2 K and up to 30 T) measurements have been performed in the series of polycrystalline intermetallics CeNiSn{sub 1-x}Ge{sub x} (0<=x<=1), which show a crossover from Kondo-lattice to fluctuating valence behaviors with x increase. Magnetostriction observed can be denominated as 'colossal' for a paramagnet (up to 0.68% at 150 K and 30 T), with no sign of saturation. Field, H, induced metamagnetic transitions associated to a change in Ce valence are observed. Three kinds of analysis of magnetostriction have been performed to ascertain the magnetostriction origin. At relatively low field and low temperatures these systems follow well the standard theory of magnetostriction (STM), revealing single-ion crystal field and exchange origins, and a determination of the alpha-symmetry microscopic magnetoelastic parameters have been performed. The valence transition is well explained in terms of the interconfigurational model, which needs an extension up to power H{sup 4}. Application of the scaling (thermodynamics corresponding low states) allows the obtainment of the Grueneisen constant, which increases with x. Needed elastic constants measurements are also reported.

  1. 47 CFR 15.513 - Technical requirements for medical imaging systems.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Technical requirements for medical imaging... DEVICES Ultra-Wideband Operation § 15.513 Technical requirements for medical imaging systems. (a) The UWB... MHz and 10,600 MHz. (b) Operation under the provisions of this section is limited to medical imaging...

  2. [Design and implementation of medical instrument standard information retrieval system based on APS.NET].

    Science.gov (United States)

    Yu, Kaijun

    2010-07-01

    This paper Analys the design goals of Medical Instrumentation standard information retrieval system. Based on the B /S structure,we established a medical instrumentation standard retrieval system with ASP.NET C # programming language, IIS f Web server, SQL Server 2000 database, in the. NET environment. The paper also Introduces the system structure, retrieval system modules, system development environment and detailed design of the system.

  3. 21 CFR 892.5050 - Medical charged-particle radiation therapy system.

    Science.gov (United States)

    2010-04-01

    ...-particle radiation therapy system. (a) Identification. A medical charged-particle radiation therapy system... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical charged-particle radiation therapy system... equipment, patient and equipment supports, treatment planning computer programs, component parts, and...

  4. 78 FR 25304 - Siemens Medical Solutions, USA, Inc., Oncology Care Systems (Radiation Oncology), Including On...

    Science.gov (United States)

    2013-04-30

    ..., USA, Inc., Oncology Care Systems (Radiation Oncology), Including On-Site Leased Workers From Source... Medical Solutions, USA, Inc., Oncology Care Systems (Radiation Oncology), including on- site leased... of February 2013, Siemens Medical Solutions, USA, Inc., Oncology Care Systems (Radiation Oncology...

  5. The control and driving system of the Bonn 3,5 GeV electron stretcher facility ELSA

    International Nuclear Information System (INIS)

    Wermelskirchen, C.

    1988-07-01

    The stretcher facility ELSA is the first accelerator of the Physical Institute the guidance of which is completely realized by the application of mini- and microcomputers. In the framework of the present thesis the whole hard- and software of this control system was developed, tested, and taken into operation. The hardware of the ELSA control system consists in the processing level of different interface cards, via which all accelerator components can be connected, and the MACS processors which drive as front-end processors the connected devices. With the transmission cable simultaneously trigger signals for the synchrotron and ELSA components are distributed. By this the MACS processors are synchronized so that all timely correlated events in the guidance of ELSA can be tuned. The modularized software on the driving central computer uses a memory-resident data bank which describes the whole accelerator configuration. In the whole it could be shown that the developed and constructed control system represents a necessary but also very comfortable and reliable instrument for the operation and driving of ELSA. (orig./HSI) [de

  6. Using Probablilistic Risk Assessment to Model Medication System Failures in Long-Term Care Facilities

    National Research Council Canada - National Science Library

    Comden, Sharon C; Marx, David; Murphy-Carley, Margaret; Hale, Misti

    2005-01-01

    .... Discussion: The models provide contextual maps of the errors and behaviors that lead to medication delivery system failures, including unanticipated risks associated with regulatory practices and common...

  7. Experimental result on the π0π0 system produced in the π+p→π+pπ0π0 reaction at 3.5 GeV/c

    International Nuclear Information System (INIS)

    Grivaz, J.F.

    1975-06-01

    The reaction π + p→π + p π 0 π 0 was investigated at 3.5 GeV/c beam momentum, in the CERN 1.2m heavy liquid bubble chamber, filled with a C 3 H 8 -CF 3 Bsub(r) mixture. 800 K pictures were analyzed and events with outgoing proton momentum + momentum + p) mass greater than 1.12 GeV and smaller than 1.36 GeV and momentum transfer to the (π + p) system smaller than .3 (GeV/c) 2 in absolute value. The π + π - →π 0 π 0 reaction cross section is then deduced from the remaining sample (125 events) and compared with theoretical predictions. Good agreement is found for (π 0 π 0 ) masses larger than approximately 600 MeV, whereas the behavior of the cross section near threshold suggests a value of the S-wave I-spin 0 scattering length larger than usually expected [fr

  8. [Marketing in the system of military-medical facilities].

    Science.gov (United States)

    Kostiuchenko, O M; Sviridova, T B

    2014-02-01

    Military medical facilities of the Ministry of Defence of the Russian, have received the right to provide additional services and have been involved in the sphere of market relations. The strong influence of market relations - an objective reality that must be used for the development of military medical institutions and improving quality of care.Effective commercial activity can improve capabilities of the military medical institutions. This requires constant study of market mechanisms to implement and develop their competitive advantage. The paper substantiates the need for the participation of military medical institutions in the provision of health services to the public on the terms of compensation incurred by financial institutions costs (paid medical services, medical assistance program of compulsory and voluntary health insurance). Taking into account the specifics of military medical institutions set out basic principles and recommendations have been implementing marketing approach in their management, the practical application of which will not only increase efficiency, but also create conditions to improve the financial and economic indicators. This knowledge will help the mechanism of functioning health care market and the rules of interaction of market counterparties.

  9. [Study on the reform and improvement of the medical device registration system in China].

    Science.gov (United States)

    Wang, Lanming

    2012-11-01

    Based on the theories of the Government Regulation and Administrative Licensure, aiming at the current situations of medical device registration system in China, some policy suggestions for future reform and improvement were provided as follows. (1) change the concepts of medical device registration administration. (2) perfect the regulations of medical device registration administration. (3) reform the medical device review organizational system. (4) Optimize the procedure of review and approval. (5) set up and maintain a professional team of review and approval staff. (6) reinforce the post-marketing supervision of medical devices. (7) foster and bring into play of the role of non-government organizations.

  10. SEARCHING FOR BINARY Y DWARFS WITH THE GEMINI MULTI-CONJUGATE ADAPTIVE OPTICS SYSTEM (GeMS)

    International Nuclear Information System (INIS)

    Opitz, Daniela; Tinney, C. G.; Faherty, Jacqueline K.; Sweet, Sarah; Gelino, Christopher R.; Kirkpatrick, J. Davy

    2016-01-01

    The NASA Wide-field Infrared Survey Explorer (WISE) has discovered almost all the known members of the new class of Y-type brown dwarfs. Most of these Y dwarfs have been identified as isolated objects in the field. It is known that binaries with L- and T-type brown dwarf primaries are less prevalent than either M-dwarf or solar-type primaries, they tend to have smaller separations and are more frequently detected in near-equal mass configurations. The binary statistics for Y-type brown dwarfs, however, are sparse, and so it is unclear if the same trends that hold for L- and T-type brown dwarfs also hold for Y-type ones. In addition, the detection of binary companions to very cool Y dwarfs may well be the best means available for discovering even colder objects. We present results for binary properties of a sample of five WISE Y dwarfs with the Gemini Multi-Conjugate Adaptive Optics System. We find no evidence for binary companions in these data, which suggests these systems are not equal-luminosity (or equal-mass) binaries with separations larger than ∼0.5–1.9 AU. For equal-mass binaries at an age of 5 Gyr, we find that the binary binding energies ruled out by our observations (i.e., 10 42 erg) are consistent with those observed in previous studies of hotter ultra-cool dwarfs

  11. [Development of a medical equipment support information system based on PDF portable document].

    Science.gov (United States)

    Cheng, Jiangbo; Wang, Weidong

    2010-07-01

    According to the organizational structure and management system of the hospital medical engineering support, integrate medical engineering support workflow to ensure the medical engineering data effectively, accurately and comprehensively collected and kept in electronic archives. Analyse workflow of the medical, equipment support work and record all work processes by the portable electronic document. Using XML middleware technology and SQL Server database, complete process management, data calculation, submission, storage and other functions. The practical application shows that the medical equipment support information system optimizes the existing work process, standardized and digital, automatic and efficient orderly and controllable. The medical equipment support information system based on portable electronic document can effectively optimize and improve hospital medical engineering support work, improve performance, reduce costs, and provide full and accurate digital data

  12. Ontological Model-Based Transparent Access To Information In A Medical Multi-Agent System

    Directory of Open Access Journals (Sweden)

    Felicia GÎZĂ-BELCIUG

    2012-01-01

    Full Text Available Getting the full electronic medical record of a patient is an important step in providing a quality medical service. But the degree of heterogeneity of data from health unit informational systems is very high, because each unit can have a different model for storing patients’ medical data. In order to achieve the interoperability and integration of data from various medical units that store partial patient medical information, this paper proposes a multi-agent systems and ontology based approach. Therefore, we present an ontological model for describing the particular structure of the data integration process. The system is to be used for centralizing the information from a patient’s partial medical records. The main advantage of the proposed model is the low ratio between the complexity of the model and the amount of information that can be retrieved in order to generate the complete medical history of a patient.

  13. Digital dissection system for medical school anatomy training

    Science.gov (United States)

    Augustine, Kurt E.; Pawlina, Wojciech; Carmichael, Stephen W.; Korinek, Mark J.; Schroeder, Kathryn K.; Segovis, Colin M.; Robb, Richard A.

    2003-05-01

    As technology advances, new and innovative ways of viewing and visualizing the human body are developed. Medicine has benefited greatly from imaging modalities that provide ways for us to visualize anatomy that cannot be seen without invasive procedures. As long as medical procedures include invasive operations, students of anatomy will benefit from the cadaveric dissection experience. Teaching proper technique for dissection of human cadavers is a challenging task for anatomy educators. Traditional methods, which have not changed significantly for centuries, include the use of textbooks and pictures to show students what a particular dissection specimen should look like. The ability to properly carry out such highly visual and interactive procedures is significantly constrained by these methods. The student receives a single view and has no idea how the procedure was carried out. The Department of Anatomy at Mayo Medical School recently built a new, state-of-the-art teaching laboratory, including data ports and power sources above each dissection table. This feature allows students to access the Mayo intranet from a computer mounted on each table. The vision of the Department of Anatomy is to replace all paper-based resources in the laboratory (dissection manuals, anatomic atlases, etc.) with a more dynamic medium that will direct students in dissection and in learning human anatomy. Part of that vision includes the use of interactive 3-D visualization technology. The Biomedical Imaging Resource (BIR) at Mayo Clinic has developed, in collaboration with the Department of Anatomy, a system for the control and capture of high resolution digital photographic sequences which can be used to create 3-D interactive visualizations of specimen dissections. The primary components of the system include a Kodak DC290 digital camera, a motorized controller rig from Kaidan, a PC, and custom software to synchronize and control the components. For each dissection procedure, the

  14. Performance of predictive models in phase equilibria of complex associating systems: PC-SAFT and CEOS/GE

    Directory of Open Access Journals (Sweden)

    N. Bender

    2013-03-01

    Full Text Available Cubic equations of state combined with excess Gibbs energy predictive models (like UNIFAC and equations of state based on applied statistical mechanics are among the main alternatives for phase equilibria prediction involving polar substances in wide temperature and pressure ranges. In this work, the predictive performances of the PC-SAFT with association contribution and Peng-Robinson (PR combined with UNIFAC (Do through mixing rules are compared. Binary and multi-component systems involving polar and non-polar substances were analyzed. Results were also compared to experimental data available in the literature. Results show a similar predictive performance for PC-SAFT with association and cubic equations combined with UNIFAC (Do through mixing rules. Although PC-SAFT with association requires less parameters, it is more complex and requires more computation time.

  15. [Research and development of medical case database: a novel medical case information system integrating with biospecimen management].

    Science.gov (United States)

    Pan, Shiyang; Mu, Yuan; Wang, Hong; Wang, Tong; Huang, Peijun; Ma, Jianfeng; Jiang, Li; Zhang, Jie; Gu, Bing; Yi, Lujiang

    2010-04-01

    To meet the needs of management of medical case information and biospecimen simultaneously, we developed a novel medical case information system integrating with biospecimen management. The database established by MS SQL Server 2000 covered, basic information, clinical diagnosis, imaging diagnosis, pathological diagnosis and clinical treatment of patient; physicochemical property, inventory management and laboratory analysis of biospecimen; users log and data maintenance. The client application developed by Visual C++ 6.0 was used to implement medical case and biospecimen management, which was based on Client/Server model. This system can perform input, browse, inquest, summary of case and related biospecimen information, and can automatically synthesize case-records based on the database. Management of not only a long-term follow-up on individual, but also of grouped cases organized according to the aim of research can be achieved by the system. This system can improve the efficiency and quality of clinical researches while biospecimens are used coordinately. It realizes synthesized and dynamic management of medical case and biospecimen, which may be considered as a new management platform.

  16. Artificial intelligence (AI) systems for interpreting complex medical datasets.

    Science.gov (United States)

    Altman, R B

    2017-05-01

    Advances in machine intelligence have created powerful capabilities in algorithms that find hidden patterns in data, classify objects based on their measured characteristics, and associate similar patients/diseases/drugs based on common features. However, artificial intelligence (AI) applications in medical data have several technical challenges: complex and heterogeneous datasets, noisy medical datasets, and explaining their output to users. There are also social challenges related to intellectual property, data provenance, regulatory issues, economics, and liability. © 2017 ASCPT.

  17. Si/Ge intermixing during Ge Stranski–Krastanov growth

    Directory of Open Access Journals (Sweden)

    Alain Portavoce

    2014-12-01

    Full Text Available The Stranski–Krastanov growth of Ge islands on Si(001 has been widely studied. The morphology changes of Ge islands during growth, from nucleation to hut/island formation and growth, followed by hut-to-dome island transformation and dislocation nucleation of domes, have been well described, even at the atomic scale, using techniques such as scanning tunneling microscopy and transmission electron microscopy. Although it is known that these islands do not consist of pure Ge (due to Si/Ge intermixing, the composition of the Ge islands is not precisely known. In the present work, atom probe tomography was used to study the composition of buried dome islands at the atomic scale, in the three-dimensional space. The core of the island was shown to contain about 55 atom % Ge, while the Ge composition surrounding this core decreases rapidly in all directions in the islands to reach a Ge concentration of about 15 atom %. The Ge distribution in the islands follows a cylindrical symmetry and Ge segregation is observed only in the {113} facets of the islands. The Ge composition of the wetting layer is not homogeneous, varying from 5 to 30 atom %.

  18. Perspectives on the changing healthcare system: teaching systems-based practice to medical residents

    Directory of Open Access Journals (Sweden)

    Johanna Martinez

    2013-09-01

    Full Text Available Purpose: The Accreditation Council for Graduate Medical Education restructured its accreditation system to be based on educational outcomes in six core competencies. Systems-based practice is one of the six core competencies. The purpose of this report is to describe Weill Cornell Medical College's Internal Medicine Residency program curriculum for systems-based practice (SBP and its evaluation process. Methods: To examine potential outcomes of the POCHS curriculum, an evaluation was conducted, examining participants': (1 knowledge gain; (2 course ratings; and (3 qualitative feedback. Results: On average, there was a 19 percentage point increase in knowledge test scores for all three cohorts. The course was rated overall highly, receiving an average of 4.6 on a 1–5 scale. Lastly, the qualitative comments supported that the material is needed and valued. Conclusion: The course, entitled Perspectives on the Changing Healthcare System (POCHS and its evaluation process support that systems-based practice is crucial to residency education. The course is designed not only to educate residents about the current health care system but also to enable them to think critically about the risk and benefits of the changes. POCHS provides a framework for teaching and assessing this competency and can serve as a template for other residency programs looking to create or restructure their SBP curriculum.

  19. Graphical User Interface for a Remote Medical Monitoring System: U.S. Army Medic Recommendations

    Science.gov (United States)

    2009-11-01

    screens. The majority of medics (70%) also wanted a name lis! screen that, when tapped , would go to an individual patient screen. In the name list...button has been pushed. Tapping on thaI button would prompt the user to enter the password. Tapping on the light button would illuminate the screen...a summary of current local weather conditions would be dis- played in the lower ! eft of the screen. In the lower right of this map screen is

  20. Integration Platform As Central Service Of Data Replication In Distributed Medical System

    Directory of Open Access Journals (Sweden)

    Wiesław Wajs

    2007-01-01

    Full Text Available The paper presents the application of Java Integration Platform (JIP to data replicationin the distributed medical system. After an introductory part on the medical system’s architecture,the focus shifts to a comparison of different approaches that exist with regard totransferring data between the system’s components. A description is given of the historicaldata processing and of the whole area of the JIP application to the medical system.

  1. The Patient-Centered Medical Home Neighbor: A Critical Concept for a Redesigned Healthcare Delivery System

    Science.gov (United States)

    2011-01-25

    Sharing Knowledge: Achieving Breakthrough Performance 2010 Military Health System Conference The Patient -Centered Medical Home Neighbor: A Critical...DATE 25 JAN 2011 2. REPORT TYPE 3. DATES COVERED 00-00-2011 to 00-00-2011 4. TITLE AND SUBTITLE The Patient -Centered Medical Home Neighbor: A...Conference What is the Patient -Centered Medical Home?  …a vision of health care as it should be  …a framework for organizing systems of care at both the

  2. [Design and realization of the communication system for the mobile medical terminal].

    Science.gov (United States)

    Ji, Lei; Guo, Xu; Shi, Huayu

    2013-01-01

    Realizing wireless communication based on handset devices for medical staff; providing an instant messaging method. Constructing a set of communication protocols and standards; developing software both on server and client. Building an instant messaging system which follows the customized specification; based on Android the client provides functions like address book, message, voice service etc. As an independent module of the mobile medical terminal, the system can provide convenient communication for medical service with other mobile business.

  3. Construction of an ''intelligent'' trigger system for kaons and study of the K+ production in the system Ne+NaF at 1.0 GeV/u

    International Nuclear Information System (INIS)

    Ahner, W.

    1993-07-01

    The technical part of this thesis describes the construction, the properties, and the experience from the application of an intelligent software trigger for the experiments on the production of positive kaons at the kaon spectrometer. The software trigger was applied in several beam-times. An essiential improvement in the yield of the registrated kaons was reached. The realization ensued by the application of standard components and represents a flexible and cost-efficient solution. The physical part of this thesis deals with the measurement of the double-differential cross section for positive kaons, positive pions, and protons in the system Ne+NaF at 1.0 GeV/u beam energy in the laboratory-angle range ofΘ lab =44 ±4 . the beam energy of 1.0 GeV/u lies below the threshold energy for the production of positive kaons in the collision of two free nucleons of E beam threshold =1.58 GeV. The momentum spectra of kaons and pions in the laboratory-momentum range from 270 MeV/c to 1140 MeV/c can be well described by a Boltzmann distribution in the c. m. system. The steepness parameter of the Boltzmann distributions amount to 64 MeV for kaons and 58 MeV for pions. The momentum-integrates cross section were determined from the extrapolation of the fitted Boltzmann distributions to: (dσ/dΩ lab ) ΔΩ lab K + =58.6±9.2 μb/sr and (dσ/dΩ lab ) ΔΩ lab π + =169±17 mb/sr. The total cross sections were calculated under the assumption of the isotropy in the c. m. system from the fitted distributions: σ 0 K + =335±52 μb and σ 0 π + =939±96 mb. The mass dependence of the meson production cross sections in the symmetrc collisional system Ne+NaF was studied and compared with the results of the study of the heavy collisional system Au+Au

  4. Solvothermal synthesis of Zn{sub 2}GeO{sub 4}:Mn{sup 2+} nanophosphor in water/diethylene glycol system

    Energy Technology Data Exchange (ETDEWEB)

    Takeshita, Satoru; Honda, Joji [Department of Applied Chemistry, Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522 (Japan); Isobe, Tetsuhiko, E-mail: isobe@applc.keio.ac.jp [Department of Applied Chemistry, Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522 (Japan); Sawayama, Tomohiro; Niikura, Seiji [SINLOIHI Company, Limited, 2-19-12 Dai, Kamakura 247-8550 (Japan)

    2012-05-15

    The influence of aging of the suspension containing the amorphous precusors on structural, compositional and photoluminescent properties is studied to understand the mechanism on the formation of Zn{sub 2}GeO{sub 4}:Mn{sup 2+} nanoparticles during the solvothermal reaction in the water/diethylene glycol mixed solvent. Aging at 200 Degree-Sign C for 20 min forms the crystalline Zn{sub 2}GeO{sub 4} nanorods and then they grow up to {approx} 50 nm in mean length after aging for 240 min. Their interplanar spacing of (410) increases with increasing the aging time. The photoluminescence intensity corresponding to the d-d transition of Mn{sup 2+} increases with increasing the aging time up to 120 min, and then decreases after aging for 240 min. The photoluminescence lifetime decreases with increasing the aging time, indicating the locally concentrated Mn{sup 2+} ions. These results reveal that Mn{sup 2+} ions gradually replace Zn{sup 2+} ions near surface through repeating dissolusion and precipitation processes during prolonged aging after the complete crystallization of Zn{sub 2}GeO{sub 4}. - Graphical abstract: TEM images of Zn{sub 2}GeO{sub 4}:Mn{sup 2+} nanoparticles aged at 200 Degree-Sign C for different aging times in the mixed solvent of water and diethylene glycol. Highlights: Black-Right-Pointing-Pointer Mechanism on formation of Zn{sub 2}GeO{sub 4}:Mn{sup 2+} nanophosphor under solvothermal condition. Black-Right-Pointing-Pointer Zn{sub 2}GeO{sub 4} nanorods crystallize via amorphous precursors. Black-Right-Pointing-Pointer Gradual substitution of Mn{sup 2+} during prolonged aging. Black-Right-Pointing-Pointer Such an inhomogeneous Mn{sup 2+} doping process results in concentration quenching.

  5. Multiwire proportional chambers in the triggering system of the streamer chamber for high-Pt charged particle production detection in 40 GeV/c hadron-nucleus interactions

    International Nuclear Information System (INIS)

    Czyrkowski, H.; Dabrowski, R.; Derlicki, A.

    1985-01-01

    We describe a triggering system based on the multiwire proportional chambers (MWPCs) for the high-P t charged particles selection in Π - A interactions at 40 GeV/c (RISC experiment). The coincidence matrices processing only combinations of hits in MWPCs allow one to reach sufficient purity of experimental material. The large area MWPCs work close to the streamer chamber high voltage electrode without any problems. Details of the fabrication procedure and peformances are also given. 12 refs. (author)

  6. Various dedicated imaging systems for routine nuclear medical applications

    International Nuclear Information System (INIS)

    Bela Kari; Tamas Gyorke; Erno Mako; Laszlo Nagy; Jozsef Turak; Oszkar Partos

    2004-01-01

    The most essential problems of nuclear medical imaging are resolution, signal/noise ratio (S/N) and sensitivity. Nowadays, the vast majority of the Anger system gamma cameras in clinical application are using parallel projection. The main problem of this projection method is the highly dependence of the image quality on the distance from the collimator surface as well as any improvement in the resolution with the distance -i.e. reduction of image blur- significantly reduces sensitivity. The aim of our research and development work was to create imaging geometry, collimator and detector constructions optimized to particular organs (brain, heart, thyroid), where it is simultaneously possible to increase the resolution and sensitivity. Main concept of the imaging geometry construction is based on the size, location and shape of a particular organ. In case of brain SPECT imaging a multiple head (4 heads in cylinder symmetric approximation) arrangement with extra high intrinsic resolution (<2.5 mm) dedicated detector design provide feasible solution for routine clinical application. The imaging system was essentially designed for Tc-99m and I-123 isotopes. The application field can be easily extended for functional small animal research and new born baby studies. Very positive feedbacks were received from both technical (stability and reproducibility of the technical parameters) and clinical sides in the past 2 years routine applications. A unique, novel conception ultra compact dedicated dual head SPECT system has been created only for 2D, 3D nuclear cardiac applications for Tc-99m and T1-201 labeled radio-pharmaceuticals. The two rectangular detectors (with <2.6 mm intrinsic resolution) are mounted fix in 90 degree geometry and move inside the special formed gantry arrangement. The unique and unusual gantry is designed to keep the detector heads as close as possible to the patient, while the patient is not exposed by any moving part. This special construction also

  7. The Medical Microrobot Control System Design via Fuzzy Logic Application

    Directory of Open Access Journals (Sweden)

    A. S. Yuschenko

    2014-01-01

    Full Text Available The aim of the investigation is the development of the instruments and technologies for diagnostics and treatment of tube-like human’s organs such as blood vessels and intestines. The medical microrobots may be applied to move along the tube-like organs by the same way as a worm. Such microrobots had been presented in some works in Russia and abroad among them is a project of BMSTU. The control system of the robot has to adapt the movement process to the peculiarity of the biology environment. The safety of the application of robotic device inside the human body is the main requirement to the construction.An experimental model of microrobot has three segments which contracting successively to ensure progressive movement of the device. The diameter of the robot is smaller than the same of the blood vessel. So it is pressed to the internal cover of the vessel by the special planes to avoid the thrombosis of the vessel. Every segment of robot contain three contact elements, pressure sensors and a regulator to control the pressure of the elements to the internal surface of the vessel. Aboard the robot is a micro-video camera has been mounted to inform the surgeon of the situation inside the vessel and other micro-devices. The supporting plates carry tens metric sensors to control the contact forces. The driver of the robot is of hydraulic type with physiologic solution to avoid the danger of embolism.Microrobot is a part of the robotic system including also a hydro-driver mounted in the stationary part of the system and intelligent interface of the operator. The surgeon-operator has opportunity to observe the inner surface of the vessel by the sensors mounted aboard the robot and to control the robot movement along the vessel. The construction of the microrobot has to guarantee the stable position of the robot in the moving blood flow and its movement inside the vessel without any damage of the inner surface.The peculiarity of the microrobot

  8. Charges Assessed the Army by the Defense Logistics Agency for Deployable Medical Systems

    National Research Council Canada - National Science Library

    1995-01-01

    .... Deployable medical systems are standardized modular field hospitals that can be prepositioned in the event of a contingency, national emergency, or war operations. In FY 1994, the Defense Personnel Support Center billed the Army $25 million for acquiring and assembling deployable medical systems.

  9. 78 FR 74163 - Harrison Medical Center, a Subsidiary of Franciscan Health System Bremerton, Washington; Notice...

    Science.gov (United States)

    2013-12-10

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-83,070] Harrison Medical Center, a Subsidiary of Franciscan Health System Bremerton, Washington; Notice of Negative Determination... workers of Harrison Medical Center, a subsidiary of Franciscan Health System, Bremerton, Washington...

  10. Advanced signal processing theory and implementation for sonar, radar, and non-invasive medical diagnostic systems

    CERN Document Server

    Stergiopoulos, Stergios

    2009-01-01

    Integrates topics of signal processing from sonar, radar, and medical system technologies by identifying their concept similarities. This book covers non-invasive medical diagnostic system applications, including intracranial ultrasound, a technology that attempts to address non-invasive detection on brain injuries and stroke.

  11. XMedIA Communication System: An XML Driven Medical Image Processing and Archiving Environment

    National Research Council Canada - National Science Library

    Sakellaris, G

    2001-01-01

    ... system meets the requirements for secure search, transaction, and presentation of medical information to the end users, whether patient or health care professional, Key features of the work include personalized access and efficient management of distributed medical knowledge, intercommunication of heterogeneous systems and presentation of information in a concise way, across different platforms.

  12. Lossy image compression for digital medical imaging systems

    Science.gov (United States)

    Wilhelm, Paul S.; Haynor, David R.; Kim, Yongmin; Nelson, Alan C.; Riskin, Eve A.

    1990-07-01

    Image compression at rates of 10:1 or greater could make PACS much more responsive and economically attractive. This paper describes a protocol for subjective and objective evaluation of the fidelity of compressed/decompressed images to the originals and presents the results ofits application to four representative and promising compression methods. The methods examined are predictive pruned tree-structured vector quantization, fractal compression, the discrete cosine transform with equal weighting of block bit allocation, and the discrete cosine transform with human visual system weighting of block bit allocation. Vector quantization is theoretically capable of producing the best compressed images, but has proven to be difficult to effectively implement. It has the advantage that it can reconstruct images quickly through a simple lookup table. Disadvantages are that codebook training is required, the method is computationally intensive, and achieving the optimum performance would require prohibitively long vector dimensions. Fractal compression is a relatively new compression technique, but has produced satisfactory results while being computationally simple. It is fast at both image compression and image reconstruction. Discrete cosine iransform techniques reproduce images well, but have traditionally been hampered by the need for intensive computing to compress and decompress images. A protocol was developed for side-by-side observer comparison of reconstructed images with originals. Three 1024 X 1024 CR (Computed Radiography) images and two 512 X 512 X-ray CT images were viewed at six bit rates (0.2, 0.4, 0.6, 0.9, 1.2, and 1.5 bpp for CR, and 1.0, 1.3, 1.6, 1.9, 2.2, 2.5 bpp for X-ray CT) by nine radiologists at the University of Washington Medical Center. The CR images were viewed on a Pixar II Megascan (2560 X 2048) monitor and the CT images on a Sony (1280 X 1024) monitor. The radiologists' subjective evaluations of image fidelity were compared to

  13. PASTE: patient-centered SMS text tagging in a medication management system.

    Science.gov (United States)

    Stenner, Shane P; Johnson, Kevin B; Denny, Joshua C

    2012-01-01

    To evaluate the performance of a system that extracts medication information and administration-related actions from patient short message service (SMS) messages. Mobile technologies provide a platform for electronic patient-centered medication management. MyMediHealth (MMH) is a medication management system that includes a medication scheduler, a medication administration record, and a reminder engine that sends text messages to cell phones. The object of this work was to extend MMH to allow two-way interaction using mobile phone-based SMS technology. Unprompted text-message communication with patients using natural language could engage patients in their healthcare, but presents unique natural language processing challenges. The authors developed a new functional component of MMH, the Patient-centered Automated SMS Tagging Engine (PASTE). The PASTE web service uses natural language processing methods, custom lexicons, and existing knowledge sources to extract and tag medication information from patient text messages. A pilot evaluation of PASTE was completed using 130 medication messages anonymously submitted by 16 volunteers via a website. System output was compared with manually tagged messages. Verified medication names, medication terms, and action terms reached high F-measures of 91.3%, 94.7%, and 90.4%, respectively. The overall medication name F-measure was 79.8%, and the medication action term F-measure was 90%. Other studies have demonstrated systems that successfully extract medication information from clinical documents using semantic tagging, regular expression-based approaches, or a combination of both approaches. This evaluation demonstrates the feasibility of extracting medication information from patient-generated medication messages.

  14. Ge-on-Si : Single-Crystal Selective Epitaxial Growth in a CVD Reactor

    NARCIS (Netherlands)

    Sammak, A.; De Boer, W.B.; Nanver, L.K.

    2012-01-01

    A standard Si/SiGe ASM CVD reactor that was recently modified for merging GaAs and Si epitaxial growth in one system is utilized to achieve intrinsic and doped epitaxial Ge-on-Si with low threading dislocation and defect densities. For this purpose, the system is equipped with 2% diluted GeH4 as the

  15. Storyboard for the Medical System Concept of Operations for Mars Exploration Missions

    Science.gov (United States)

    Antonsen, Eric; Hailey, Melinda; Reyes, David; Rubin, David; Urbina, Michelle

    2017-01-01

    This storyboard conceptualizes one scenario of an integrated medical system during a Mars exploration mission. All content is for illustrative purposes only and neither defines nor implies system design requirement.

  16. Reducing and Sustaining Duplicate Medical Record Creation by Usability Testing and System Redesign.

    Science.gov (United States)

    Khunlertkit, Adjhaporn; Dorissaint, Leonard; Chen, Allen; Paine, Lori; Pronovost, Peter J

    2017-10-25

    Duplicate medical record creation is a common and consequential health care systems error often caused by poor search system usability and inappropriate user training. We conducted two phases of scenario-based usability testing with patient registrars working in areas at risk of generating duplicate medical records. Phase 1 evaluated the existing search system, which led to system redesigns. Phase 2 tested the redesigned system to mitigate potential errors before health system-wide implementation. To evaluate system effectiveness, we compared the monthly potential duplicate medical record rates for preimplementation and postimplementation months. The existing system could not effectively handle a misspelling, which led to failed search and duplicate medical record creation. Using the existing system, 96% of registrars found commonly spelled patient names whereas only 69% successfully found complicated names. Registrars lacked knowledge and usage of a phonetic matching function to assist in misspelling. The new system consistently captured the correct patient regardless of misspelling, but search returned more potential matches, resulting in, on average, 4 seconds longer to select common names. Potential monthly duplicate medical record rate reduced by 38%, from 4% to 2.3% after implementation of the new system, and has sustained at an average of 2.5% for 2 years. Usability testing was an effective method to reveal problems and aid system redesign to deliver a more user friendly system, hence reducing the potential for medical record duplication. Greater standards for usability would ensure that these improvements can be realized before rather than after exposing patients to risks.

  17. Advances in intelligent analysis of medical data and decision support systems

    CERN Document Server

    Iantovics, Barna

    2013-01-01

    This volume is a result of the fruitful and vivid discussions during the MedDecSup'2012 International Workshop bringing together a relevant body of knowledge, and new developments in the increasingly important field of medical informatics. This carefully edited book presents new ideas aimed at the development of intelligent processing of various kinds of medical information and the perfection of the contemporary computer systems for medical decision support. The book presents advances of the medical information systems for intelligent archiving, processing, analysis and search-by-content which will improve the quality of the medical services for every patient and of the global healthcare system. The book combines in a synergistic way theoretical developments with the practicability of the approaches developed and presents the last developments and achievements in  medical informatics to a broad range of readers: engineers, mathematicians, physicians, and PhD students.

  18. A review of medical malpractice issues in Malaysia under tort litigation system.

    Science.gov (United States)

    Hambali, Siti Naaishah; Khodapanahandeh, Solmaz

    2014-04-07

    Medical malpractice cases are a matter of much concern in many countries including Malaysia where several cases caught the attention of the public and authorities. Although comprehensive annual statistics on medical negligence claims are not available in Malaysia since such data are not collected systematically in this country there are indications of an upward trend. Medical malpractice cases have been publicized by the media, academic researchers and in government annual reports prompting government policy makers, oversight agencies and the medical profession itself to take appropriate action. The increasing dissatisfaction with the current tort litigation system requires exploring alternatives and new approaches for handling medical malpractice cases. This study aims to examine the difficulties inherent in the tort system in Malaysia for solving medical malpractice claims and evaluates the structure of this system from the perspective of effectiveness, fairness, compensation, accessibility, and accountability.

  19. Review of Medical Malpractice Issues in Malaysia under Tort Litigation System

    Science.gov (United States)

    Hambali, Siti Naaishah; Khodapanahandeh, Solmaz

    2014-01-01

    Medical malpractice cases are a matter of much concern in many countries including Malaysia where several cases caught the attention of the public and authorities. Although comprehensive annual statistics on medical negligence claims are not available in Malaysia since such data are not collected systematically in this country there are indications of an upward trend. Medical malpractice cases have been publicized by the media, academic researchers and in government annual reports prompting government policy makers, oversight agencies and the medical profession itself to take appropriate action. The increasing dissatisfaction with the current tort litigation system requires exploring alternatives and new approaches for handling medical malpractice cases. This study aims to examine the difficulties inherent in the tort system in Malaysia for solving medical malpractice claims and evaluates the structure of this system from the perspective of effectiveness, fairness, compensation, accessibility, and accountability. PMID:24999124

  20. Development of 68Ge/68Ga Generator using 30 MeV Cyclotron

    International Nuclear Information System (INIS)

    Goo, Hur Min; Dae, Yang Seung; Hoon, Park Jeong; Dae, Park Yong; Je, Lee Eun; Bae, Kong Young; Kim, In Jong; Lee, Jin Woo; Hyun, Yu Kook

    2012-05-01

    The purpose of this research is to develop the 68 Ge/ 68 Ga generator where daughter nuclide 68 Ga can be eluted according to the designated periods from the resin which holds mother nuclide 68 Ge absorbed and to develop the 68 Ga utilization technology. 1. Target development for 68 Ge target and production of 68 Ge - Target designed for 68 Ge production with 30 MeV cyclotron - Target body material evaluation and proton beam irradiation 2. Separation of 68 Ge and development of column material and extraction system for 68 Ge/ 68 Ga separation - Development of 68 Ge separation method from nat Ga target - Development of absorbents for generator using stable isotope 3. Development of 68 Ga labelled radiopharmaceutical - Development of 68 Ga labelled benzamide derivative for diagnosis of melanoma - Development of 68 Ga dendrimer complex using nano-technology 4. Development of shield case for 68 Ge/ 68 Ga generator

  1. The Use of Hospital Information Systems Data Base with Word Processing and Other Medical Records System Applications

    OpenAIRE

    Rusnak, James E.

    1982-01-01

    The approach frequently used to introduce computer technology into a hospital Medical Records Department is to implement a Word Processing System. Word processing is a form of computer system application that is intended to improve the department's productivity by improving the medical information transcription process. The effectiveness of the Word Processing System may be further enhanced by installing system facilities to provide access to data processing file information in the Hospital's...

  2. Continuing medical education in Europe: towards a harmonised system.

    NARCIS (Netherlands)

    Costa, A.; Hemelryck, F. Van; Aparicio, A.; Gatzemeier, W.; Leer, J.W.H.; Maillet, B.; Hossfeld, D.K.

    2010-01-01

    One of the first reports on the state of medical education was published in 1910 in North America, with the support of the Carnegie Foundation, showing that the interest for this issue dates back at least a century. Doctors (and nurses) are among the few professionals who managed to avoid for a long

  3. Evaluating medical and systemic factors related to maternal and ...

    African Journals Online (AJOL)

    Background: This study examined maternal morbidity and mortality and neonatal mortality over a multi-year period from de-identified retrospective medical records at Nyakahanga Designated District Hospital in north-western Tanzania. The study aimed to examine factors related to maternal mortality (MMR) and morbidity in ...

  4. Growth and evolution of nickel germanide nanostructures on Ge(001)

    International Nuclear Information System (INIS)

    Grzela, T; Capellini, G; Schubert, M A; Schroeder, T; Koczorowski, W; Czajka, R; Curson, N J; Heidmann, I; Schmidt, Th; Falta, J

    2015-01-01

    Nickel germanide is deemed an excellent material system for low resistance contact formation for future Ge device modules integrated into mainstream, Si-based integrated circuit technologies. In this study, we present a multi-technique experimental study on the formation processes of nickel germanides on Ge(001). We demonstrate that room temperature deposition of ∼1 nm of Ni on Ge(001) is realized in the Volmer–Weber growth mode. Subsequent thermal annealing results first in the formation of a continuous Ni_xGe_y wetting layer featuring well-defined terrace morphology. Upon increasing the annealing temperature to 300 °C, we observed the onset of a de-wetting process, characterized by the appearance of voids on the Ni_xGe_y terraces. Annealing above 300 °C enhances this de-wetting process and the surface evolves gradually towards the formation of well-ordered, rectangular Ni_xGe_y 3D nanostructures. Annealing up to 500 °C induces an Ostwald ripening phenomenon, with smaller nanoislands disappearing and larger ones increasing their size. Subsequent annealing to higher temperatures drives the Ni-germanide diffusion into the bulk and the consequent formation of highly ordered, {111} faceted Ni-Ge nanocrystals featuring an epitaxial relationship with the substrate Ni-Ge (101); (010) || Ge(001); (110). (paper)

  5. Development of case-based medication alerting and recommender system: a new approach to prevention for medication error.

    Science.gov (United States)

    Miyo, Kengo; Nittami, Yuki S; Kitagawa, Yoichiro; Ohe, Kazuhiko

    2007-01-01

    The purpose of this study was to develop a new alerting and recommender system for preventing medication errors. In recent years, alerting systems have been widely implemented, but because these systems apply a same static threshold for all patients in all cases, they produce excessive alerts and subject physicians to "alert fatigue". We believe that the most commonly-written prescription for a patient's status is the safest one. From this standpoint, we developed a real-time case-based medication alerting and recommender system linked to a database of past prescriptions. When a physician issues his or her prescription, our system dynamically compares it with past ones for similar patients in the database. An analysis of the 10 most frequently-used drugs in the University of Tokyo Hospital revealed that our system reduced the number of false alerts compared to the traditional static alert method. Our system contributes to the creation of alerts that are appropriate for patients' clinical conditions and based on physicians' empirical discretion.

  6. Impact of universal medical insurance system on the accessibility of medical service supply and affordability of patients in China

    Science.gov (United States)

    Zhang, Zhiguo; Ren, Jing; Zhang, Jie; Pan, Xiaoyun; Zhang, Liang; Jin, Si

    2018-01-01

    Background China’s universal medical insurance system (UMIS) is designed to promote social fairness through improving access to medical services and reducing out-of-pocket (OOP) costs for all Chinese. However, it is still not known whether UMIS has a significant impact on the accessibility of medical service supply and the affordability, as well as the seeking-care choice, of patients in China. Methods Segmented time-series regression analysis, as a powerful statistical method of interrupted time series design, was used to estimate the changes in the quantity and quality of medical service supply before and after the implementation of UMIS. The rates of catastrophic payments and seeking-care choices for UMIS beneficiaries were selected to measure the affordability and medical service flow of patients after the implementation of UMIS. Results China’s UMIS was established in 2008. After that, the trending increase of the expenditure of the UMIS was higher than that of increase in revenue compared to previous years. Up to 2014, the UMIS had covered 97.5% of the entire population in China. After introduction of the UMIS, there were significant increases in licensed physicians, nurses, and hospital beds per 1000 individuals. In addition, hospital outpatient visits and inpatient visits per year increased compared to the pre-UMIS period. The average fatality rate of inpatients in the overall hospital and general hospital and the average fatality rate due to acute myocardial infarction (AMI) in general hospitals was significantly decreased. In contrast, no significant and prospective changes were observed in rural physicians per 1000 individuals, inpatient visits and inpatient fatality rate in the community centers and township hospitals compared to the pre-UMIS period. After 2008, the rates of catastrophic payments for UMIS inpatients at different income levels were declining at three levels of hospitals. Whichever income level, the rate of catastrophic payments for

  7. Improving the Efficiency of Medical Services Systems: A New Integrated Mathematical Modeling Approach

    Directory of Open Access Journals (Sweden)

    Davood Shishebori

    2013-01-01

    Full Text Available Nowadays, the efficient design of medical service systems plays a critical role in improving the performance and efficiency of medical services provided by governments. Accordingly, health care planners in countries especially with a system based on a National Health Service (NHS try to make decisions on where to locate and how to organize medical services regarding several conditions in different residence areas, so as to improve the geographic equity of comfortable access in the delivery of medical services while accounting for efficiency and cost issues especially in crucial situations. Therefore, optimally locating of such services and also suitable allocating demands them, can help to enhance the performance and responsiveness of medical services system. In this paper, a multiobjective mixed integer nonlinear programming model is proposed to decide locations of new medical system centers, link roads that should be constructed or improved, and also urban residence centers covered by these medical service centers and link roads under investment budget constraint in order to both minimize the total transportation cost of the overall system and minimize the total failure cost (i.e., maximize the system reliability of medical service centers under unforeseen situations. Then, the proposed model is linearized by suitable techniques. Moreover, a practical case study is presented in detail to illustrate the application of the proposed mathematical model. Finally, a sensitivity analysis is done to provide an insight into the behavior of the proposed model in response to changes of key parameters of the problem.

  8. A partial-wave analysis of the neutral 3 pi system produced in the reaction pi /sup -/p to ( pi /sup +/ pi /sup -/ pi /sup 0/)n at 12 and 15 GeV/c

    CERN Document Server

    Corden, M J; Bellamy, E H; Corbett, I F; Dagan, S; Dowell, John D; Esterling, R J; Garvey, J; Gnat, Y; Green, M G; Harnew, N; Jobes, M; Kenyon, I R; Lipman, Norman H; Lister, J B; Lister, J R; Litchfield, P J; Mawson, J; McMahon, T; Robertson, A W; Stacey, B J; Strong, J A; Sumorok, K; Thomas, D H

    1978-01-01

    Data on the charge-exchange reaction pi /sup -/p to ( pi /sup +/ pi /sup -/ pi /sup 0/)n have been taken at beam momenta of 12 and 15 GeV /c, using the CERN Omega Multiparticle Spectrometer. A partial-wave analysis has been made of the (3 pi )/sup 0/ system. Both natural and unnatural spin-parity production was observed. The natural parity states can be identified with established resonances. In addition a natural spin-parity enhancement is observed at a mass of about 2 GeV/c /sup 2/ with J/sup P/=4/sup +/ preferred. This effect is called the A /sub 2/*(2030). The unnatural spin-parity production found is consistent with reggeized Deck model predictions. No unambiguous A/sub 1/ or A/sub 3/ production is observed. (15 refs).

  9. System size and energy dependence of jet-induced hadron pair correlation shapes in Cu+Cu and Au+Au collisions at square root sNN=200 and 62.4 GeV.

    Science.gov (United States)

    Adare, A; Adler, S S; Afanasiev, S; Aidala, C; Ajitanand, N N; Akiba, Y; Al-Bataineh, H; Alexander, J; Al-Jamel, A; Aoki, K; Aphecetche, L; Armendariz, R; Aronson, S H; Asai, J; Atomssa, E T; Averbeck, R; Awes, T C; Azmoun, B; Babintsev, V; Baksay, G; Baksay, L; Baldisseri, A; Barish, K N; Barnes, P D; Bassalleck, B; Bathe, S; Batsouli, S; Baublis, V; Bauer, F; Bazilevsky, A; Belikov, S; Bennett, R; Berdnikov, Y; Bickley, A A; Bjorndal, M T; Boissevain, J G; Borel, H; Boyle, K; Brooks, M L; Brown, D S; Bruner, N; Bucher, D; Buesching, H; Bumazhnov, V; Bunce, G; Burward-Hoy, J M; Butsyk, S; Camard, X; Campbell, S; Chai, J-S; Chand, P; Chang, B S; Chang, W C; Charvet, J-L; Chernichenko, S; Chiba, J; Chi, C Y; Chiu, M; Choi, I J; Choudhury, R K; Chujo, T; Chung, P; Churyn, A; Cianciolo, V; Cleven, C R; Cobigo, Y; Cole, B A; Comets, M P; Constantin, P; Csanád, M; Csörgo, T; Cussonneau, J P; Dahms, T; Das, K; David, G; Deák, F; Deaton, M B; Dehmelt, K; Delagrange, H; Denisov, A; d'Enterria, D; Deshpande, A; Desmond, E J; Devismes, A; Dietzsch, O; Dion, A; Donadelli, M; Drachenberg, J L; Drapier, O; Drees, A; Dubey, A K; Durum, A; Dutta, D; Dzhordzhadze, V; Efremenko, Y V; Egdemir, J; Ellinghaus, F; Emam, W S; Enokizono, A; En'yo, H; Espagnon, B; Esumi, S; Eyser, K O; Fields, D E; Finck, C; Finger, M; Finger, M; Fleuret, F; Fokin, S L; Forestier, B; Fox, B D; Fraenkel, Z; Frantz, J E; Franz, A; Frawley, A D; Fujiwara, K; Fukao, Y; Fung, S-Y; Fusayasu, T; Gadrat, S; Garishvili, I; Gastineau, F; Germain, M; Glenn, A; Gong, H; Gonin, M; Gosset, J; Goto, Y; Granier de Cassagnac, R; Grau, N; Greene, S V; Grosse Perdekamp, M; Gunji, T; Gustafsson, H-A; Hachiya, T; Hadj Henni, A; Haegemann, C; Haggerty, J S; Hagiwara, M N; Hamagaki, H; Han, R; Hansen, A G; Harada, H; Hartouni, E P; Haruna, K; Harvey, M; Haslum, E; Hasuko, K; Hayano, R; Heffner, M; Hemmick, T K; Hester, T; Heuser, J M; He, X; Hidas, P; Hiejima, H; Hill, J C; Hobbs, R; Hohlmann, M; Holmes, M; Holzmann, W; Homma, K; Hong, B; Hoover, A; Horaguchi, T; Hornback, D; Hur, M G; Ichihara, T; Ikonnikov, V V; Imai, K; Inaba, M; Inoue, Y; Inuzuka, M; Isenhower, D; Isenhower, L; Ishihara, M; Isobe, T; Issah, M; Isupov, A; Jacak, B V; Jia, J; Jin, J; Jinnouchi, O; Johnson, B M; Johnson, S C; Joo, K S; Jouan, D; Kajihara, F; Kametani, S; Kamihara, N; Kamin, J; Kaneta, M; Kang, J H; Kanou, H; Katou, K; Kawabata, T; Kawagishi, T; Kawall, D; Kazantsev, A V; Kelly, S; Khachaturov, B; Khanzadeev, A; Kikuchi, J; Kim, D H; Kim, D J; Kim, E; Kim, G-B; Kim, H J; Kim, Y-S; Kinney, E; Kiss, A; Kistenev, E; Kiyomichi, A; Klay, J; Klein-Boesing, C; Kobayashi, H; Kochenda, L; Kochetkov, V; Kohara, R; Komkov, B; Konno, M; Kotchetkov, D; Kozlov, A; Král, A; Kravitz, A; Kroon, P J; Kubart, J; Kuberg, C H; Kunde, G J; Kurihara, N; Kurita, K; Kweon, M J; Kwon, Y; Kyle, G S; Lacey, R; Lai, Y-S; Lajoie, J G; Lebedev, A; Le Bornec, Y; Leckey, S; Lee, D M; Lee, M K; Lee, T; Leitch, M J; Leite, M A L; Lenzi, B; Lim, H; Liska, T; Litvinenko, A; Liu, M X; Li, X; Li, X H; Love, B; Lynch, D; Maguire, C F; Makdisi, Y I; Malakhov, A; Malik, M D; Manko, V I; Mao, Y; Martinez, G; Masek, L; Masui, H; Matathias, F; Matsumoto, T; McCain, M C; McCumber, M; McGaughey, P L; Miake, Y; Mikes, P; Miki, K; Miller, T E; Milov, A; Mioduszewski, S; Mishra, G C; Mishra, M; Mitchell, J T; Mitrovski, M; Mohanty, A K; Morreale, A; Morrison, D P; Moss, J M; Moukhanova, T V; Mukhopadhyay, D; Muniruzzaman, M; Murata, J; Nagamiya, S; Nagata, Y; Nagle, J L; Naglis, M; Nakagawa, I; Nakamiya, Y; Nakamura, T; Nakano, K; Newby, J; Nguyen, M; Norman, B E; Nyanin, A S; Nystrand, J; O'Brien, E; Oda, S X; Ogilvie, C A; Ohnishi, H; Ojha, I D; Okada, H; Okada, K; Oka, M; Omiwade, O O; Oskarsson, A; Otterlund, I; Ouchida, M; Oyama, K; Ozawa, K; Pak, R; Pal, D; Palounek, A P T; Pantuev, V; Papavassiliou, V; Park, J; Park, W J; Pate, S F; Pei, H; Penev, V; Peng, J-C; Pereira, H; Peresedov, V; Peressounko, D Yu; Pierson, A; Pinkenburg, C; Pisani, R P; Purschke, M L; Purwar, A K; Qualls, J M; Qu, H; Rak, J; Rakotozafindrabe, A; Ravinovich, I; Read, K F; Rembeczki, S; Reuter, M; Reygers, K; Riabov, V; Riabov, Y; Roche, G; Romana, A; Rosati, M; Rosendahl, S S E; Rosnet, P; Rukoyatkin, P; Rykov, V L; Ryu, S S; Sahlmueller, B; Saito, N; Sakaguchi, T; Sakai, S; Sakata, H; Samsonov, V; Sanfratello, L; Santo, R; Sato, H D; Sato, S; Sawada, S; Schutz, Y; Seele, J; Seidl, R; Semenov, V; Seto, R; Sharma, D; Shea, T K; Shein, I; Shevel, A; Shibata, T-A; Shigaki, K; Shimomura, M; Shohjoh, T; Shoji, K; Sickles, A; Silva, C L; Silvermyr, D; Silvestre, C; Sim, K S; Singh, C P; Singh, V; Skutnik, S; Slunecka, M; Smith, W C; Soldatov, A; Soltz, R A; Sondheim, W E; Sorensen, S P; Sourikova, I V; Staley, F; Stankus, P W; Stenlund, E; Stepanov, M; Ster, A; Stoll, S P; Sugitate, T; Suire, C; Sullivan, J P; Sziklai, J; Tabaru, T; Takagi, S; Takagui, E M; Taketani, A; Tanaka, K H; Tanaka, Y; Tanida, K; Tannenbaum, M J; Taranenko, A; Tarján, P; Thomas, T L; Togawa, M; Toia, A; Tojo, J; Tomásek, L; Torii, H; Towell, R S; Tram, V-N; Tserruya, I; Tsuchimoto, Y; Tuli, S K; Tydesjö, H; Tyurin, N; Uam, T J; Vale, C; Valle, H; vanHecke, H W; Velkovska, J; Velkovsky, M; Vertesi, R; Veszprémi, V; Vinogradov, A A; Virius, M; Volkov, M A; Vrba, V; Vznuzdaev, E; Wagner, M; Walker, D; Wang, X R; Watanabe, Y; Wessels, J; White, S N; Willis, N; Winter, D; Wohn, F K; Woody, C L; Wysocki, M; Xie, W; Yamaguchi, Y L; Yanovich, A; Yasin, Z; Ying, J; Yokkaichi, S; Young, G R; Younus, I; Yushmanov, I E; Zajc, W A; Zaudtke, O; Zhang, C; Zhou, S; Zimányi, J; Zolin, L; Zong, X

    2007-06-08

    We present azimuthal angle correlations of intermediate transverse momentum (1-4 GeV/c) hadrons from dijets in Cu+Cu and Au+Au collisions at square root sNN=62.4 and 200 GeV. The away-side dijet induced azimuthal correlation is broadened, non-Gaussian, and peaked away from Delta phi=pi in central and semicentral collisions in all the systems. The broadening and peak location are found to depend upon the number of participants in the collision, but not on the collision energy or beam nuclei. These results are consistent with sound or shock wave models, but pose challenges to Cherenkov gluon radiation models.

  10. [Development of performance evaluation and management system on advanced schistosomiasis medical treatment].

    Science.gov (United States)

    Zhou, Xiao-Rong; Huang, Shui-Sheng; Gong, Xin-Guo; Cen, Li-Ping; Zhang, Cong; Zhu, Hong; Yang, Jun-Jing; Chen, Li

    2012-04-01

    To construct a performance evaluation and management system on advanced schistosomiasis medical treatment, and analyze and evaluate the work of the advanced schistosomiasis medical treatment over the years. By applying the database management technique and C++ programming technique, we inputted the information of the advanced schistosomiasis cases into the system, and comprehensively evaluated the work of the advanced schistosomiasis medical treatment through the cost-effect analysis, cost-effectiveness analysis, and cost-benefit analysis. We made a set of software formula about cost-effect analysis, cost-effectiveness analysis, and cost-benefit analysis. This system had many features such as clear building, easy to operate, friendly surface, convenient information input and information search. It could benefit the performance evaluation of the province's advanced schistosomiasis medical treatment work. This system can satisfy the current needs of advanced schistosomiasis medical treatment work and can be easy to be widely used.

  11. Medical Data Manager an Interface between PACS and the gLite Data Management System

    CERN Document Server

    Montagnat, Johan; Texier, Romain; Nienartowicz, Krzysztof; Baud, Jean-Philippe

    2008-01-01

    The medical imaging community uses the DICOM image format and protocol to store and exchange data. The Medical Data Manager (MDM) is an interface between DICOM compliant systems such as PACS and the EGEE Data Management System. It opens hospital imaging networks to the world scale Grid while protecting sensitive medical data. It can be accessed transparently from any gLite service. It is an important milestone towards adoption of Grid technologies in the medical imaging community. Hospitals continuously produce tremendous amounts of image data that is managed by local PACS (Picture Archiving and Communication Systems). These systems are often limited to a local network access although the community experiences a growing interest for data sharing and remote processing. Indeed, patient data is often spread out different medical data acquisition centers. Furthermore, researchers in the area often need to analyze large populations whose data can be gathered through federations of PACS. Opening PACS to the outer I...

  12. Development of Rural Emergency Medical System (REMS) with Geospatial Technology in Malaysia

    Science.gov (United States)

    Ooi, W. H.; Shahrizal, I. M.; Noordin, A.; Nurulain, M. I.; Norhan, M. Y.

    2014-02-01

    Emergency medical services are dedicated services in providing out-of-hospital transport to definitive care or patients with illnesses and injuries. In this service the response time and the preparedness of medical services is of prime importance. The application of space and geospatial technology such as satellite navigation system and Geographical Information System (GIS) was proven to improve the emergency operation in many developed countries. In collaboration with a medical service NGO, the National Space Agency (ANGKASA) has developed a prototype Rural Emergency Medical System (REMS), focusing on providing medical services to rural areas and incorporating satellite based tracking module integrated with GIS and patience database to improve the response time of the paramedic team during emergency. With the aim to benefit the grassroots community by exploiting space technology, the project was able to prove the system concept which will be addressed in this paper.

  13. Lattice parameters values and phase diagram for the Cu{sub 2}Zn{sub 1−z}Mn{sub z}GeSe{sub 4} alloy system

    Energy Technology Data Exchange (ETDEWEB)

    Caldera, D. [Centro de Estudios de Semiconductores, Departamento de Física, Facultad de Ciencias, Universidad de Los Andes, Mérida 5101 (Venezuela, Bolivarian Republic of); Quintero, M., E-mail: mquinter@ula.ve [Centro de Estudios de Semiconductores, Departamento de Física, Facultad de Ciencias, Universidad de Los Andes, Mérida 5101 (Venezuela, Bolivarian Republic of); Morocoima, M.; Moreno, E.; Quintero, E.; Grima-Gallardo, P.; Bocaranda, P. [Centro de Estudios de Semiconductores, Departamento de Física, Facultad de Ciencias, Universidad de Los Andes, Mérida 5101 (Venezuela, Bolivarian Republic of); Henao, J.A.; Macías, M.A. [Grupo de Investigación en Química Estructural (GIQUE), Facultad de Ciencias, Escuela de Química, Universidad Industrial de Santander, Apartado aéreo 678, Bucaramanga (Colombia); Briceño, J.M.; Mora, A.E. [Laboratorio de Análisis Químico y Estructura de Materiales, Departamento de Física, Universidad de Los Andes, Mérida 5101 (Venezuela, Bolivarian Republic of)

    2014-11-25

    Highlights: • The samples were annealed at 500 °C for 1 month. • Samples in the ranges 0 < z < 0.375 had the tetragonal stannite α structure (I4{sup ¯}2m). • For 0.725 < z ⩽ 1 the wurtz–stannite δ structure (Pmn2{sub 1}). • Undercooling effects occur for samples in the range 0.725 < z < 0.925. - Abstract: The T(z) phase diagram of the Cu{sub 2}Zn{sub 1−z}Mn{sub z}GeSe{sub 4} alloy system is obtained from X-ray diffraction and differential thermal analysis DTA. At room temperature, the X-ray diffraction data showed that samples in the ranges 0 < z < 0.375 had the tetragonal stannite α structure (I4{sup ¯}2m), while for 0.725 < z ⩽ 1 the wurtz–stannite δ structure (Pmn2{sub 1}). The α and δ fields are separated by a relative wide three-phase field (α + δ + MnSe{sub 2}). The DTA thermograms were used to construct the phase diagram of the Cu{sub 2}Zn{sub 1−z}Mn{sub z}GeSe{sub 4} alloy system. It was confirmed that the Cu{sub 2}ZnGeSe{sub 4} and Cu{sub 2}MnGeSe{sub 4} compounds melt incongruently. It was observed that undercooling effects occur for samples in the range 0.725 < z < 0.925.

  14. Evaluating the Medical Kit System for the International Space Station(ISS) - A Paradigm Revisited

    Science.gov (United States)

    Hailey, Melinda J.; Urbina, Michelle C.; Hughlett, Jessica L.; Gilmore, Stevan; Locke, James; Reyna, Baraquiel; Smith, Gwyn E.

    2010-01-01

    Medical capabilities aboard the International Space Station (ISS) have been packaged to help astronaut crew medical officers (CMO) mitigate both urgent and non-urgent medical issues during their 6-month expeditions. Two ISS crewmembers are designated as CMOs for each 3-crewmember mission and are typically not physicians. In addition, the ISS may have communication gaps of up to 45 minutes during each orbit, necessitating medical equipment that can be reliably operated autonomously during flight. The retirement of the space shuttle combined with ten years of manned ISS expeditions led the Space Medicine Division at the NASA Johnson Space Center to reassess the current ISS Medical Kit System. This reassessment led to the system being streamlined to meet future logistical considerations with current Russian space vehicles and future NASA/commercial space vehicle systems. Methods The JSC Space Medicine Division coordinated the development of requirements, fabrication of prototypes, and conducted usability testing for the new ISS Medical Kit System in concert with implementing updated versions of the ISS Medical Check List and associated in-flight software applications. The teams constructed a medical kit system with the flexibility for use on the ISS, and resupply on the Russian Progress space vehicle and future NASA/commercial space vehicles. Results Prototype systems were developed, reviewed, and tested for implementation. Completion of Preliminary and Critical Design Reviews resulted in a streamlined ISS Medical Kit System that is being used for training by ISS crews starting with Expedition 27 (June 2011). Conclusions The team will present the process for designing, developing, , implementing, and training with this new ISS Medical Kit System.

  15. Managing medical and insurance information through a smart-card-based information system.

    Science.gov (United States)

    Lambrinoudakis, C; Gritzalis, S

    2000-08-01

    The continuously increased mobility of patients and doctors, in conjunction with the existence of medical groups consisting of private doctors, general practitioners, hospitals, medical centers, and insurance companies, pose significant difficulties on the management of patients' medical data. Inevitably this affects the quality of the health care services provided. The evolving smart card technology can be utilized for the implementation of a secure portable electronic medical record, carried by the patient herself/himself. In addition to the medical data, insurance information can be stored in the smart card thus facilitating the creation of an "intelligent system" supporting the efficient management of patient's data. In this paper we present the main architectural and functional characteristics of such a system. We also highlight how the security features offered by smart cards can be exploited in order to ensure confidentiality and integrity of the medical data stored in the patient cards.

  16. A Medical Consultation System to Support Health Care of Inhabitants through A Dialogue with Artificial Intelligence

    Science.gov (United States)

    Miyake, Hiroshi; Masuzawa, Hideaki

    A medical consultation system has been developed that encompasses knowledge of various specialties. The system is designed to be used by general practitioners, and inhabitants themselves. It has the characteristics of ; 1. The input task of complaints is simplified by use of multiple choice questionaires. 2. The system advices the person whether to seek medical help or not, and if so, the degree of urgency, and from what type of practitioner or specialist. 3. It supplies the doctor information regarding essential symptoms and possible diagnosis. 4. The system offer easy tools to make a medical consultation system to the specialists themselves. This system is intended as an answer to the common problem of uncertainty on the part of both inhabitants and doctors as to the area of medical speciality that applies to a given disease.

  17. A Detailed Analysis of Prehospital Interventions in Common Medical Priority Dispatch System Determinants

    Directory of Open Access Journals (Sweden)

    Sporer, Karl A

    2011-02-01

    Full Text Available Background: Medical Priority Dispatch System (MPDS is a type of Emergency Medical Dispatch (EMD system used to prioritize 9-1-1 calls and optimize resource allocation. Dispatchers use a series of scripted questions to assign determinants to calls based on chief complaint and acuity.Objective: We analyzed the prehospital interventions performed on patients with MPDS determinants for breathing problems, chest pain, unknown problem (man down, seizures, fainting (unconscious and falls for transport status and interventions.Methods: We matched all prehospital patients in complaint-based categories for breathing problems, chest pain, unknown problem (man down, seizures, fainting (unconscious and falls from January 1, 2004, to December 31, 2006, with their prehospital record. Calls were queried for the following prehospital interventions: Basic Life Support care only, intravenous line placement only, medication given, procedures or non-transport. We defined Advanced Life Support (ALS interventions as the administration of a medication or a procedure.Results: Of the 77,394 MPDS calls during this period, 31,318 (40% patients met inclusion criteria. Breathing problems made up 12.2%, chest pain 6%, unknown problem 1.4%, seizures 3%, falls 9% and unconscious/fainting 9% of the total number of MPDS calls. Patients with breathing problem had a low rate of procedures (0.7% and cardiac arrest medications (1.6% with 38% receiving some medication. Chest pain patients had a similar distribution; procedures (0.5%, cardiac arrest medication (1.5% and any medication (64%. Unknown problem: procedures (1%, cardiac arrest medication (1.3%, any medication (18%. Patients with Seizures had a low rate of procedures (1.1% and cardiac arrest medications (0.6% with 20% receiving some medication. Fall patients had a lower rate of severe illness with more medication, mostly morphine: procedures (0.2%, cardiac arrest medication (0.2%, all medications (28%. Unconscious

  18. The Vanuatu medical supply system – documenting opportunities and challenges to meet the Millennium Development Goals

    OpenAIRE

    Brown, Andrew; Gilbert, Ben

    2012-01-01

    Objectives: Limited human resources are widely recognised as a barrier to achieve health-related Millennium Development Goals. Availability of medical supplies and suitably trained health personnel are crucial to ensuring a well-functioning medical supply system. The objective of this paper is to identify the factors which influence the availability of medical supplies within the health facilities of Vanuatu. Methods: A qualitative triangulated strategy using semi-structured interviews, obser...

  19. Medication management strategies used by older adults with heart failure: A systems-based analysis.

    Science.gov (United States)

    Mickelson, Robin S; Holden, Richard J

    2017-09-01

    Older adults with heart failure use strategies to cope with the constraining barriers impeding medication management. Strategies are behavioral adaptations that allow goal achievement despite these constraining conditions. When strategies do not exist, are ineffective or maladaptive, medication performance and health outcomes are at risk. While constraints to medication adherence are described in literature, strategies used by patients to manage medications are less well-described or understood. Guided by cognitive engineering concepts, the aim of this study was to describe and analyze the strategies used by older adults with heart failure to achieve their medication management goals. This mixed methods study employed an empirical strategies analysis method to elicit medication management strategies used by older adults with heart failure. Observation and interview data collected from 61 older adults with heart failure and 31 caregivers were analyzed using qualitative content analysis to derive categories, patterns and themes within and across cases. Data derived thematic sub-categories described planned and ad hoc methods of strategic adaptations. Stable strategies proactively adjusted the medication management process, environment, or the patients themselves. Patients applied situational strategies (planned or ad hoc) to irregular or unexpected situations. Medication non-adherence was a strategy employed when life goals conflicted with medication adherence. The health system was a source of constraints without providing commensurate strategies. Patients strived to control their medication system and achieve goals using adaptive strategies. Future patient self-mangement research can benefit from methods and theories used to study professional work, such as strategies analysis.

  20. New hospital payment systems: comparing medical strategies in The Netherlands, Germany and England.

    Science.gov (United States)

    van Essen, Anne Marije

    2009-01-01

    This paper seeks to identify different medical strategies adopted in relation to the new hospital payment systems in Germany, The Netherlands and England and analyse how the medical strategies have impacted on the emergence of these New Public Management policy tools between 2002 and 2007. A comparative approach is applied. In addition to secondary sources, the study uses publications in professional journals, official publications of the (national) physician organisations and a (non-random) expert questionnaire to obtain the views of the medical corporate bodies in the three countries. The results reveal differences in the medical strategies in the three countries that point towards the significance of institutional and interest configurations. The Dutch corporate medical body was most willing to solve the conflict, while the German and English corporate medical bodies seem to be keen to use a strategy of confrontation. The differences in medical strategies also impact on the ways in which hospital payment systems have emerged in the three countries. Further research is necessary to study the medical strategies in healthcare reforms from a broader perspective, for instance by including other countries. The paper gives insights into the interplay between the medical profession and the government in the context of new managerial governance practices in the hospital sector. It adds to the scholarly debates about the role of the medical profession in health policy-making.

  1. Assimilating South African medical students trained in Cuba into the South African medical education system: reflections from an identity perspective

    Directory of Open Access Journals (Sweden)

    B. M. Donda

    2016-10-01

    Full Text Available Abstract Background In terms of the Nelson Mandela Fidel Castro Medical Collaboration programme, an agreement between the governments of South Africa and Cuba, cohorts of South African students receive their initial five years medical training at a Cuban university before returning to South Africa for a six to twelve months orientation before integration into the local final year class. It is common for these students to experience academic difficulty on their return. Frequently this is viewed merely as a matter of a knowledge deficit. Discussion We argue that the problem arises from a fundamental divergence in the outcomes of the Cuban and South African medical curricula, each of which is designed with a particular healthcare system in mind. Using the discrepancy theory of identity proposed by Higgins in 1987, we discuss the challenges experienced by the returning Nelson Mandela Fidel Castro Medical Collaboration students in terms of a potential crisis of identity and suggest interventions which may prove valuable in promoting academic success and successful integration. Conclusions Though providing additional training to address the gap in skills and knowledge in returning students is an important part of their successful reintegration, this could be insufficient on its own and must be complemented by a range of measures designed to ameliorate the discrepancies in identity which arise from the transition from one educational model to another.

  2. Assimilating South African medical students trained in Cuba into the South African medical education system: reflections from an identity perspective.

    Science.gov (United States)

    Donda, B M; Hift, R J; Singaram, V S

    2016-10-24

    In terms of the Nelson Mandela Fidel Castro Medical Collaboration programme, an agreement between the governments of South Africa and Cuba, cohorts of South African students receive their initial five years medical training at a Cuban university before returning to South Africa for a six to twelve months orientation before integration into the local final year class. It is common for these students to experience academic difficulty on their return. Frequently this is viewed merely as a matter of a knowledge deficit. We argue that the problem arises from a fundamental divergence in the outcomes of the Cuban and South African medical curricula, each of which is designed with a particular healthcare system in mind. Using the discrepancy theory of identity proposed by Higgins in 1987, we discuss the challenges experienced by the returning Nelson Mandela Fidel Castro Medical Collaboration students in terms of a potential crisis of identity and suggest interventions which may prove valuable in promoting academic success and successful integration. Though providing additional training to address the gap in skills and knowledge in returning students is an important part of their successful reintegration, this could be insufficient on its own and must be complemented by a range of measures designed to ameliorate the discrepancies in identity which arise from the transition from one educational model to another.

  3. Measuring diversity in medical reports based on categorized attributes and international classification systems

    Directory of Open Access Journals (Sweden)

    Přečková Petra

    2012-04-01

    Full Text Available Abstract Background Narrative medical reports do not use standardized terminology and often bring insufficient information for statistical processing and medical decision making. Objectives of the paper are to propose a method for measuring diversity in medical reports written in any language, to compare diversities in narrative and structured medical reports and to map attributes and terms to selected classification systems. Methods A new method based on a general concept of f-diversity is proposed for measuring diversity of medical reports in any language. The method is based on categorized attributes recorded in narrative or structured medical reports and on international classification systems. Values of categories are expressed by terms. Using SNOMED CT and ICD 10 we are mapping attributes and terms to predefined codes. We use f-diversities of Gini-Simpson and Number of Categories types to compare diversities of narrative and structured medical reports. The comparison is based on attributes selected from the Minimal Data Model for Cardiology (MDMC. Results We compared diversities of 110 Czech narrative medical reports and 1119 Czech structured medical reports. Selected categorized attributes of MDMC had mostly different numbers of categories and used different terms in narrative and structured reports. We found more than 60% of MDMC attributes in SNOMED CT. We showed that attributes in narrative medical reports had greater diversity than the same attributes in structured medical reports. Further, we replaced each value of category (term used for attributes in narrative medical reports by the closest term and the category used in MDMC for structured medical reports. We found that relative Gini-Simpson diversities in structured medical reports were significantly smaller than those in narrative medical reports except the "Allergy" attribute. Conclusions Terminology in narrative medical reports is not standardized. Therefore it is nearly

  4. A cloud system for mobile medical services of traditional Chinese medicine.

    Science.gov (United States)

    Hu, Nian-Ze; Lee, Chia-Ying; Hou, Mark C; Chen, Ying-Ling

    2013-12-01

    Many medical centers in Taiwan have started to provide Traditional Chinese Medicine (TCM) services for hospitalized patients. Due to the complexity of TCM modality and the increasing need for providing TCM services for patients in different wards at distantly separate locations within the hospital, it is getting difficult to manage the situation in the traditional way. A computerized system with mobile ability can therefore provide a practical solution to the challenge presented. The study tries to develop a cloud system equipped with mobile devices to integrate electronic medical records, facilitate communication between medical workers, and improve the quality of TCM services for the hospitalized patients in a medical center. The system developed in the study includes mobile devices carrying Android operation system and a PC as a cloud server. All the devices use the same TCM management system developed by the study. A website of database is set up for information sharing. The cloud system allows users to access and update patients' medical information, which is of great help to medical workers for verifying patients' identification and giving proper treatments to patients. The information then can be wirelessly transmitted between medical personnel through the cloud system. Several quantitative and qualitative evaluation indexes are developed to measure the effectiveness of the cloud system on the quality of the TCM service. The cloud system is tested and verified based on a sample of hospitalized patients receiving the acupuncture treatment at the Lukang Branch of Changhua Christian Hospital (CCH) in Taiwan. The result shows a great improvement in operating efficiency of the TCM service in that a significant saving in labor time can be attributable to the cloud system. In addition, the cloud system makes it easy to confirm patients' identity through taking a picture of the patient upon receiving any medical treatment. The result also shows that the cloud system

  5. Making medical treatments resilient to technological disruptions in telemedicine systems

    NARCIS (Netherlands)

    Larburu Rubio, Nekane; Widya, I.A.; Bults, Richard G.A.; Hermens, Hermanus J.

    Telemedicine depends on Information and Communication Technology (ICT) to support remote treatment of patients. This dependency requires the telemedicine system design to be resilient for ICT performance degradation or subsystem failures. Nevertheless, using telemedicine systems create a dependency

  6. Database Capture of Natural Language Echocardiographic Reports: A Unified Medical Language System Approach

    OpenAIRE

    Canfield, K.; Bray, B.; Huff, S.; Warner, H.

    1989-01-01

    We describe a prototype system for semi-automatic database capture of free-text echocardiography reports. The system is very simple and uses a Unified Medical Language System compatible architecture. We use this system and a large body of texts to create a patient database and develop a comprehensive hierarchical dictionary for echocardiography.

  7. Building a national electronic medical record exchange system - experiences in Taiwan.

    Science.gov (United States)

    Li, Yu-Chuan Jack; Yen, Ju-Chuan; Chiu, Wen-Ta; Jian, Wen-Shan; Syed-Abdul, Shabbir; Hsu, Min-Huei

    2015-08-01

    There are currently 501 hospitals and about 20,000 clinics in Taiwan. The National Health Insurance (NHI) system, which is operated by the NHI Administration, uses a single-payer system and covers 99.9% of the nation's total population of 23,000,000. Taiwan's NHI provides people with a high degree of freedom in choosing their medical care options. However, there is the potential concern that the available medical resources will be overused. The number of doctor consultations per person per year is about 15. Duplication of laboratory tests and prescriptions are not rare either. Building an electronic medical record exchange system is a good method of solving these problems and of improving continuity in health care. In November 2009, Taiwan's Executive Yuan passed the 'Plan for accelerating the implementation of electronic medical record systems in medical institutions' (2010-2012; a 3-year plan). According to this plan, a patient can, at any hospital in Taiwan, by using his/her health insurance IC card and physician's medical professional IC card, upon signing a written agreement, retrieve all important medical records for the past 6 months from other participating hospitals. The focus of this plan is to establish the National Electronic Medical Record Exchange Centre (EEC). A hospital's information system will be connected to the EEC through an electronic medical record (EMR) gateway. The hospital will convert the medical records for the past 6 months in its EMR system into standardized files and save them on the EMR gateway. The most important functions of the EEC are to generate an index of all the XML files on the EMR gateways of all hospitals, and to provide search and retrieval services for hospitals and clinics. The EEC provides four standard inter-institution EMR retrieval services covering medical imaging reports, laboratory test reports, discharge summaries, and outpatient records. In this system, we adopted the Health Level 7 (HL7) Clinical Document

  8. Vital Signs Monitoring System Using Radio Frequency Communication: A Medical Care Terminal for Beddridden People Support

    Directory of Open Access Journals (Sweden)

    Fábio FERREIRA

    2015-02-01

    Full Text Available In this paper, the data transmission of an acquisition system for biomedical vital signs via Radio Frequency (RF communication is explored. This system can be considered a medical care terminal (MCT. It was developed a platform capable of recording the patient's physiological signals to check if any medical evolution/change occurred. The system allows also acquiring the environment data, as for example the room temperature and luminosity. The main achievement of this paper is the patients’ real-time health condition monitoring by the medical personnel or caregivers that will contribute to prevent health problems, especially for bedridden people with reduced mobility.

  9. Medical and technology requirements for human solar system exploration missions

    Science.gov (United States)

    Nicogossian, Arnauld; Harris, Leonard; Couch, Lana; Sulzman, Frank; Gaiser, Karen

    1989-01-01

    Measures that need to be taken to cope with the health problems posed by zero gravity and radiation in manned solar system exploration missions are discussed. The particular systems that will be used aboard Space Station Freedom are addressed, and relevant human factors problems are examined. The development of a controlled ecological life support system is addressed.

  10. The influences of patient's satisfaction with medical service delivery, assessment of medical service, and trust in health delivery system on patient's life satisfaction in China.

    Science.gov (United States)

    Tang, Liyang

    2012-09-14

    Patient's satisfaction with medical service delivery/assessment of medical service/trust in health delivery system may have significant influence on patient's life satisfaction in China's health delivery system/in various kinds of hospitals.The aim of this study was to test whether and to what extent patient's satisfaction with medical service delivery/patient's assessments of various major aspects of medical service/various major aspects of patient's trust in health delivery system influenced patient's life satisfaction in China's health delivery system/in various kinds of hospitals. This study collaborated with National Bureau of Statistics of China to carry out a 2008 national urban resident household survey in 17 provinces, autonomous regions, and municipalities directly under the central government (N = 3,386), and specified ordered probit models were established to analyze dataset from this household survey. The key considerations in generating patient's life satisfaction involved patient's overall satisfaction with medical service delivery, assessment of doctor-patient communication, assessment of medical cost, assessment of medical treatment process, assessment of medical facility and hospital environment, assessment of waiting time for medical service, trust in prescription, trust in doctor, and trust in recommended medical examination. But the major considerations in generating patient's life satisfaction were different among low level public hospital, high level public hospital, and private hospital. The promotion of patient's overall satisfaction with medical service delivery, the improvement of doctor-patient communication, the reduction of medical cost, the improvement of medical treatment process, the promotion of medical facility and hospital environment, the reduction of waiting time for medical service, the promotion of patient's trust in prescription, the promotion of patient's trust in doctor, and the promotion of patient's trust in

  11. [Design and Implementation of a Mobile Operating Room Information Management System Based on Electronic Medical Record].

    Science.gov (United States)

    Liu, Baozhen; Liu, Zhiguo; Wang, Xianwen

    2015-06-01

    A mobile operating room information management system with electronic medical record (EMR) is designed to improve work efficiency and to enhance the patient information sharing. In the operating room, this system acquires the information from various medical devices through the Client/Server (C/S) pattern, and automatically generates XML-based EMR. Outside the operating room, this system provides information access service by using the Browser/Server (B/S) pattern. Software test shows that this system can correctly collect medical information from equipment and clearly display the real-time waveform. By achieving surgery records with higher quality and sharing the information among mobile medical units, this system can effectively reduce doctors' workload and promote the information construction of the field hospital.

  12. Medical tourism’s impact for health systems: A study from three Asian countries

    Directory of Open Access Journals (Sweden)

    Ala`a Nimer AbuKhalifeh

    2015-12-01

    Full Text Available Medical tourism is a growing phenomenon with policy implications for health systems, particularly of destination countries. Private actors and governments in Southeast Asia are promoting the medical tourist industry, but the potential impact on health systems, particularly in terms of equity in access and availability for local consumers, is unclear. This article presents a conceptual framework that outlines the policy implications of medical tourism’s growth for health systems, illustration on the cases of Thailand, Singapore and Malaysia, three provincial centres for medical tourism, via an extensive review of academic and grey literature. Variables for further analysis of the potential impact of medical tourism on health systems are also identified. The framework can provide a basis for empirical, in country studies weighing the benefits and disadvantages of medical tourism for health systems. The policy implications described are of particular relevance for policymakers and industry practitioners in other Southeast Asian countries with similar health systems where governments have expressed interest in facilitating the growing of the medical tourist industry.

  13. The potential for intelligent decision support systems to improve the quality and consistency of medication reviews.

    Science.gov (United States)

    Bindoff, I; Stafford, A; Peterson, G; Kang, B H; Tenni, P

    2012-08-01

    Drug-related problems (DRPs) are of serious concern worldwide, particularly for the elderly who often take many medications simultaneously. Medication reviews have been demonstrated to improve medication usage, leading to reductions in DRPs and potential savings in healthcare costs. However, medication reviews are not always of a consistently high standard, and there is often room for improvement in the quality of their findings. Our aim was to produce computerized intelligent decision support software that can improve the consistency and quality of medication review reports, by helping to ensure that DRPs relevant to a patient are overlooked less frequently. A system that largely achieved this goal was previously published, but refinements have been made. This paper examines the results of both the earlier and newer systems. Two prototype multiple-classification ripple-down rules medication review systems were built, the second being a refinement of the first. Each of the systems was trained incrementally using a human medication review expert. The resultant knowledge bases were analysed and compared, showing factors such as accuracy, time taken to train, and potential errors avoided. The two systems performed well, achieving accuracies of approximately 80% and 90%, after being trained on only a small number of cases (126 and 244 cases, respectively). Through analysis of the available data, it was estimated that without the system intervening, the expert training the first prototype would have missed approximately 36% of potentially relevant DRPs, and the second 43%. However, the system appeared to prevent the majority of these potential expert errors by correctly identifying the DRPs for them, leaving only an estimated 8% error rate for the first expert and 4% for the second. These intelligent decision support systems have shown a clear potential to substantially improve the quality and consistency of medication reviews, which should in turn translate into

  14. Feasibility study of P2P-type system architecture with 3D medical image data support for medical integrated network systems

    International Nuclear Information System (INIS)

    Noji, Tamotsu; Arino, Masashi; Suto, Yasuzo

    2010-01-01

    We are investigating an integrated medical network system with an electronic letter of introduction function and a 3D image support function operating in the Internet environment. However, the problems with current C/S (client/server)-type systems are inadequate security countermeasures and insufficient transmission availability. In this report, we propose a medical information cooperation system architecture that employs a P2P (peer-to-peer)-type communication method rather than a C/S-type method, which helps to prevent a reduction in processing speed when large amounts of data (such as 3D images) are transferred. In addition, a virtual clinic was created and a feasibility study was conducted to evaluate the P2P-type system. The results showed that efficiency was improved by about 77% in real-time transmission, suggesting that this system may be suitable for practical application. (author)

  15. A Selective Group Authentication Scheme for IoT-Based Medical Information System.

    Science.gov (United States)

    Park, YoHan; Park, YoungHo

    2017-04-01

    The technology of IoT combined with medical systems is expected to support advanced medical services. However, unsolved security problems, such as misuse of medical devices, illegal access to the medical server and so on, make IoT-based medical systems not be applied widely. In addition, users have a high burden of computation to access Things for the explosive growth of IoT devices. Because medical information is critical and important, but users have a restricted computing power, IoT-based medical systems are required to provide secure and efficient authentication for users. In this paper, we propose a selective group authentication scheme using Shamir's threshold technique. The property of selectivity gives the right of choice to users to form a group which consists of things users select and access. And users can get an access authority for those Things at a time. Thus, our scheme provides an efficient user authentication for multiple Things and conditional access authority for safe IoT-based medical information system. To the best of our knowledge, our proposed scheme is the first in which selectivity is combined with group authentication in IoT environments.

  16. Impact of Child Sexual Abuse Medical Examinations on the Dependency and Criminal Systems.

    Science.gov (United States)

    De Jong, Allan R.

    1998-01-01

    Reviews previous research on the sociolegal impact of medical evaluations for child sexual abuse; offers a recommended menu of research questions, concerning process and outcomes of these evaluations, interviewing techniques, the use of medical evidence in prosecution, and knowledge level of professionals in the criminal and dependency systems.…

  17. Implementation of an Interorganizational System: The Case of Medical Insurance E-Clearance

    Science.gov (United States)

    Bose, Indranil; Liu, Han; Ye, Alex

    2012-01-01

    The patients receiving treatment from a hospital need to interact with multiple entities when claiming reimbursements. The complexities of the medical service supply chain can be simplified with an electronic clearance management system that allows hospitals, medical insurance bureau, bank, and patients to interact in a seamless and cashless…

  18. The specification of a frame-based medical terminological system in Protégé

    NARCIS (Netherlands)

    Abu-Hanna, Ameen; Cornet, Ronald; de Keizer, Nicolette

    2004-01-01

    A medical terminological system (TS) is essentially a representation of concepts, attributes and relationships pertaining to medical terms. Although the requirements and structures of TSs have enjoyed some attention in the literature, the actual implementation of TSs consisted so far of ad-hoc

  19. An Automated Medical Information Management System (OpScan-MIMS) in a Clinical Setting

    Science.gov (United States)

    Margolis, S.; Baker, T.G.; Ritchey, M.G.; Alterescu, S.; Friedman, C.

    1981-01-01

    This paper describes an automated medical information management system within a clinic setting. The system includes an optically scanned data entry system (OpScan), a generalized, interactive retrieval and storage software system(Medical Information Management System, MIMS) and the use of time-sharing. The system has the advantages of minimal hardware purchase and maintenance, rapid data entry and retrieval, user-created programs, no need for user knowledge of computer language or technology and is cost effective. The OpScan-MIMS system has been operational for approximately 16 months in a sexually transmitted disease clinic. The system's application to medical audit, quality assurance, clinic management and clinical training are demonstrated.

  20. Gastroenterology Curriculum in the Canadian Medical School System.

    Science.gov (United States)

    Dang, ThucNhi Tran; Wong, Clarence; Bistritz, Lana

    2017-01-01

    Background and Purpose. Gastroenterology is a diverse subspecialty that covers a wide array of topics. The preclinical gastroenterology curriculum is often the only formal training that medical students receive prior to becoming residents. There is no Canadian consensus on learning objectives or instructional methods and a general lack of awareness of curriculum at other institutions. This results in variable background knowledge for residents and lack of guidance for course development. Objectives. (1) Elucidate gastroenterology topics being taught at the preclinical level. (2) Determine instructional methods employed to teach gastroenterology content. Results . A curriculum map of gastroenterology topics was constructed from 10 of the medical schools that responded. Topics often not taught included pediatric GI diseases, surgery and trauma, food allergies/intolerances, and obesity. Gastroenterology was taught primarily by gastroenterologists and surgeons. Didactic and small group teaching was the most employed teaching method. Conclusion. This study is the first step in examining the Canadian gastroenterology curriculum at a preclinical level. The data can be used to inform curriculum development so that topics generally lacking are better incorporated in the curriculum. The study can also be used as a guide for further curriculum design and alignment across the country.

  1. High quality Ge epilayer on Si (1 0 0) with an ultrathin Si1-x Ge x /Si buffer layer by RPCVD

    Science.gov (United States)

    Chen, Da; Guo, Qinglei; Zhang, Nan; Xu, Anli; Wang, Bei; Li, Ya; Wang, Gang

    2017-07-01

    The authors report a method to grow high quality strain-relaxed Ge epilayer on a combination of low temperature Ge seed layer and Si1-x Ge x /Si superlattice buffer layer by reduced pressure chemical vapor deposition system without any subsequent annealing treatment. Prior to the growth of high quality Ge epilayer, an ultrathin Si1-x Ge x /Si superlattice buffer layer with the thickness of 50 nm and a 460 nm Ge seed layer were deposited successively at low temperature. Then an 840 nm Ge epilayer was grown at high deposition rate with the surface root-mean-square roughness of 0.707 nm and threading dislocation density of 2.5  ×  106 cm-2, respectively. Detailed investigations of the influence of ultrathin low-temperature Si1-x Ge x /Si superlattice buffer layer on the quality of Ge epilayer were performed, which indicates that the crystalline quality of Ge epilayer can be significantly improved by enhancing the Ge concentration of Si1-x Ge x /Si superlattice buffer layer.

  2. Formation of Ge dot or film in Ge/Si heterostructure by using sub-monolayer carbon deposition on top and in-situ post annealing

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, Yuhki, E-mail: itoh.yuhki@ecei.tohoku.ac.jp; Hatakeyama, Shinji; Kawashima, Tomoyuki; Washio, Katsuyoshi

    2016-03-01

    Effects of carbon (C) atoms on solid-phase epitaxial growth of Ge on Si(100) have been studied. C and Ge layers were deposited on Si(100) substrates at low temperature (150–300 °C) by using solid-source molecular beam epitaxy (MBE) system and subsequently annealed at 650 °C in the MBE chamber. The surface morphology after annealing changed depending on deposited amounts of C and deposition temperature of Ge. Ge dots were formed for small amounts of C while smooth Ge films were formed by large amounts of C varying with the Ge deposition temperature. The surface morphology after annealing was also affected by the as-deposited Ge crystallinity. The change in surface morphology depending on the amounts of deposited C was considered to be affected by the formation of Ge–C bonds which relieved the misfit strain between Ge and Si. The crystallinity of Ge deteriorated with increasing C coverage due to the incorporation of insoluble C atoms in the shape of both dots and films. - Highlights: • Effects of carbon on solid-phase epitaxy of C/Ge/Si(100) were studied. • Surface morphology changed depending on C amounts and Ge deposition temperature. • Solid-phase growth of Ge changed from large dots to smooth films with C coverage. • Transition of surface morphology was affected by the formation of Ge–C bonds.

  3. [A Medical Devices Management Information System Supporting Full Life-Cycle Process Management].

    Science.gov (United States)

    Tang, Guoping; Hu, Liang

    2015-07-01

    Medical equipments are essential supplies to carry out medical work. How to ensure the safety and reliability of the medical equipments in diagnosis, and reduce procurement and maintenance costs is a topic of concern to everyone. In this paper, product lifecycle management (PLM) and enterprise resource planning (ERP) are cited to establish a lifecycle management information system. Through integrative and analysis of the various stages of the relevant data in life-cycle, it can ensure safety and reliability of medical equipments in the operation and provide the convincing data for meticulous management.

  4. Application of epithermal neutron activation in multielement analysis of silicate rocks employing both coaxial Ge(Li) and low energy photon detector systems

    Science.gov (United States)

    Baedecker, P.A.; Rowe, J.J.; Steinnes, E.

    1977-01-01

    The instrumental activation analysis of silicate rocks using epithermal neutrons has been studied using both high resolution coaxial Ge(Li) detectors and low energy photon detectors, and applied to the determination of 23 elements in eight new U.S.G.S. standard rocks. The analytical use X-ray peaks associated with electron capture or internal conversion processes has been evaluated. Of 28 elements which can be considered to be determinable by instrumental means, the epithermal activation approach is capable of giving improved sensitivity and precision in 16 cases, over the normal INAA procedure. In eleven cases the use of the low energy photon detector is thought to show advantages over convertional coaxial Ge(Li) spectroscopy. ?? 1977 Akade??miai Kiado??.

  5. EXAFS and RDF studies of Ge27S53I20 glass

    International Nuclear Information System (INIS)

    Nasu, H.; Myoren, H.; Makida, S.; Imura, T.; Osaka, Y.

    1988-01-01

    Detailed X-ray diffraction measurements and extended X-ray absorption fine structure (EXAFS) have been applied to Ge 23 S 57 I 20 glass as a typical chalcohalide glass and to GeS 2 glass for comparison, in order to investigate the structure of Ge-S-I glass system. From the derived curves against atomic distance, the formation of Ge-I bonds is evidenced in the glass structure. (author) 4 refs., 2 figs., 1 tab

  6. [Development and application of emergency medical information management system].

    Science.gov (United States)

    Wang, Fang; Zhu, Baofeng; Chen, Jianrong; Wang, Jian; Gu, Chaoli; Liu, Buyun

    2011-03-01

    To meet the needs of clinical practice of rescuing critical illness and develop the information management system of the emergency medicine. Microsoft Visual FoxPro, which is one of Microsoft's visual programming tool, is used to develop computer-aided system included the information management system of the emergency medicine. The system mainly consists of the module of statistic analysis, the module of quality control of emergency rescue, the module of flow path of emergency rescue, the module of nursing care in emergency rescue, and the module of rescue training. It can realize the system management of emergency medicine and,process and analyze the emergency statistical data. This system is practical. It can optimize emergency clinical pathway, and meet the needs of clinical rescue.

  7. MAX phase – Alumina composites via elemental and exchange reactions in the Ti{sub n+1}AC{sub n} systems (A=Al, Si, Ga, Ge, In and Sn)

    Energy Technology Data Exchange (ETDEWEB)

    Cuskelly, Dylan, E-mail: dylan.cuskelly@uon.edu.au; Richards, Erin; Kisi, Erich, E-mail: Erich.Kisi@newcastle.edu.au

    2016-05-15

    Extension of the aluminothermal exchange reaction synthesis of M{sub n+1}AX{sub n} phases to systems where the element ‘A’ is not the reducing agent was investigated in systems TiO{sub 2}–A–Al–C for A=Al, Si, Ga, Ge, In and Sn as well as Cr{sub 2}O{sub 3}–Ga–Al–C. MAX phase-Al{sub 2}O{sub 3} composites were made in all systems except those with A=Ga or In. The effectiveness of conversion to MAX phases was generally in the range 63–96% without optimisation of starting ratios. Optimisation in the Ti–Si–C system gave a MAX phase component with >98% Ti{sub 3}SiC{sub 2}. - Graphical abstract: A range of Ti{sub n+1}AX{sub n} phases with different A elements were synthesised directly from the M oxide via exchange reactions. The process has now been shown to be general in all the systems marked in green in the table. - Highlights: • Ti{sub n+1}AC{sub n} phases were produced via a single step exchange reaction. • 3 MAX phase systems were successful via this method for the first time. • Cr{sub 2}GeC was also able to be produced via an exchange reaction. • The interconversion reaction in MAX phases is more general than previously thought.

  8. Structure of 78Ge from the 76Ge(t,p)78Ge reaction

    International Nuclear Information System (INIS)

    Ardouin, D.; Lebrun, C.; Guilbault, F.; Remaud, B.; Vergnes, M.N.; Rotbard, G.; Kumar, K.

    1978-01-01

    The 76 Ge(t,p) 78 Ge reaction has been performed at a bombarding energy of 17 MeV. Thirteen excited states below 3 MeV excitation are reported with Jsup(π) values obtained by comparison to DWBA analysis. A comparison to a dynamical deformation theory is made and the results suggest 78 Ge is a transitional nucleus nearing spherical shape due to the proximity of the N-50 closed shell

  9. Applying Toyota production system techniques for medication delivery: improving hospital safety and efficiency.

    Science.gov (United States)

    Newell, Terry L; Steinmetz-Malato, Laura L; Van Dyke, Deborah L

    2011-01-01

    The inpatient medication delivery system used at a large regional acute care hospital in the Midwest had become antiquated and inefficient. The existing 24-hr medication cart-fill exchange process with delivery to the patients' bedside did not always provide ordered medications to the nursing units when they were needed. In 2007 the principles of the Toyota Production System (TPS) were applied to the system. Project objectives were to improve medication safety and reduce the time needed for nurses to retrieve patient medications. A multidisciplinary team was formed that included representatives from nursing, pharmacy, informatics, quality, and various operational support departments. Team members were educated and trained in the tools and techniques of TPS, and then designed and implemented a new pull system benchmarking the TPS Ideal State model. The newly installed process, providing just-in-time medication availability, has measurably improved delivery processes as well as patient safety and satisfaction. Other positive outcomes have included improved nursing satisfaction, reduced nursing wait time for delivered medications, and improved efficiency in the pharmacy. After a successful pilot on two nursing units, the system is being extended to the rest of the hospital. © 2010 National Association for Healthcare Quality.

  10. Dynamics of the phase transitions in the system of nonequilibrium charge carriers in quantum-dimensional Si{sub 1−x}Ge{sub x}/Si structures

    Energy Technology Data Exchange (ETDEWEB)

    Bagaev, V. S.; Krivobok, V. S., E-mail: krivobok@lebedev.ru; Nikolaev, S. N.; Onishchenko, E. E.; Pruchkina, A. A.; Aminev, D. F.; Skorikov, M. L. [Russian Academy of Sciences, Lebedev Physical Institute (Russian Federation); Lobanov, D. N.; Novikov, A. V. [Russian Academy of Sciences, Institute for Physics of Microstructures (Russian Federation)

    2013-11-15

    The dynamics of the phase transition from an electron-hole plasma to an exciton gas is studied during pulsed excitation of heterostructures with Si{sub 1−x}Ge{sub x}/Si quantum wells. The scenario of the phase transition is shown to depend radically on the germanium content in the Si{sub 1−x}Ge{sub x} layer. The electron-hole system decomposes into a rarefied exciton and a dense plasma phases for quantum wells with a germanium content x = 3.5% in the time range 100–500 ns after an excitation pulse. In this case, the electron-hole plasma existing in quantum wells has all signs of an electron-hole liquid. A qualitatively different picture of the phase transition is observed for quantum wells with x = 9.5%, where no separation into phases with different electronic spectra is detected. The carrier recombination in the electron-hole plasma leads a gradual weakening of screening and the appearance of exciton states. For a germanium content of 5–7%, the scenario of the phase transition is complex: 20–250 ns after an excitation pulse, the properties of the electron-hole system are described in terms of a homogeneous electron-hole plasma, whereas its separation into an electron-hole liquid and an exciton gas is detected after 350 ns. It is shown that, for the electron-hole liquid to exist in quantum wells with x = 5–7% Ge, the exciton gas should have a substantially higher density than in quantum wells with x = 3.5% Ge. This finding agrees with a decrease in the depth of the local minimum of the electron-hole plasma energy with increasing germanium concentration in the SiGe layer. An increase in the density of the exciton gas coexisting with the electron-hole liquid is shown to enhance the role of multiparticle states, which are likely to be represented by trions T{sup +} and biexcitons, in the exciton gas.

  11. [Study of the Application of Mobile Medical Technology in Construction of Grading Diagnosis and Treatment System].

    Science.gov (United States)

    Zhu, Wenwu; Shen, Yihong; Zhen, Hui; Yang, Xiaohe; Hu, Kai

    2018-02-08

    The combination of mobile medical technology and the grading diagnosis and treatment system (GDTS) can stimulate the allocation of medical resources, reduce medical cost and improve public health significantly. Firstly we summarize development features of mobile medical technology in foreign and domestic market, then we study the application model of mobile medical application in GDTS with field research data and analyzes its advantage and shortage. Finally, we propose four measures for further developing mobile medical application in the GDTS:the government departments should formulate policies and industry standards of products as soon as possible to meet requirement of market; service providers should take the hospitals as core role to achieve mutual benefit and win-win situation; take the daily monitoring of chronic diseases as an entry point to build profitable business model; enhance publicity to promote public health awareness.

  12. Knowledge of medical students on National Health Care System: A French multicentric survey.

    Science.gov (United States)

    Feral-Pierssens, A-L; Jannot, A-S

    2017-09-01

    Education on national health care policy and costs is part of our medical curriculum explaining how our health care system works. Our aim was to measure French medical students' knowledge about national health care funding, costs and access and explore association with their educational and personal background. We developed a web-based survey exploring knowledge on national health care funding, access and costs through 19 items and measured success score as the number of correct answers. We also collected students' characteristics and public health training. The survey was sent to undergraduate medical students and residents from five medical universities between July and November 2015. A total of 1195 students from 5 medical universities responded to the survey. Most students underestimated the total amount of annual medical expenses, hospitalization costs and the proportion of the general population not benefiting from a complementary insurance. The knowledge score was not associated with medical education level. Three students' characteristics were significantly associated with a better knowledge score: male gender, older age, and underprivileged status. Medical students have important gaps in knowledge regarding national health care funding, coverage and costs. This knowledge was not associated with medical education level but with some of the students' personal characteristics. All these results are of great concern and should lead us to discussion and reflection about medical and public health training. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  13. System-size dependence of charged kaon and pion production in nucleus-nucleus collisions at beam energies of 40A GeV and 158A GeV

    International Nuclear Information System (INIS)

    Ströbele, H

    2014-01-01

    We present the system size (centrality) dependence of the mean transverse mass, of the K/π ratio, and the width of the rapidity distributions. Except for the latter a steep increase with centrality is observed for small systems followed by a weak rise or even saturation for higher centralities at both energies. This behavior is compared to calculations using transport models (UrQMD and HSD), a percolation model and the core-corona approach

  14. Measurement of energy transitions for the decay radiations of 75Ge and 69Ge in a high purity germanium detector

    Science.gov (United States)

    Aydın, Güral; Usta, Metin; Oktay, Adem

    2018-06-01

    Photoactivation experiments have a wide range of application areas in nuclear, particle physics, and medical physics such as measuring energy levels and half-lifes of nuclei, experiments for understanding imaging methods in medicine, isotope production for patient treatment, radiation security and transportation, radiation therapy, and astrophysics processes. In this study, some energy transition values of the decay radiations of 75Ge and 69Ge, which are the products of photonuclear reactions (γ, n) with germanium isotopes (75Ge and 69Ge), were measured. The gamma spectrum as a result of atomic transitions were analysed by using a high purity semiconductor germanium detector and the energy transition values which are presented here were compared with the ones which are the best in literature. It was observed that the results presented are in agreement with literature in error range and some results have better precisions.

  15. Photoluminescence and electroluminescence from Ge/strained GeSn/Ge quantum wells

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Chung-Yi; Chang, Chih-Chiang [Department of Electrical Engineering, Graduate Institute of Photonics and Optoelectronics, National Taiwan University, Taipei 10617, Taiwan (China); Huang, Chih-Hsiung; Huang, Shih-Hsien [Department of Electrical Engineering, Graduate Institute of Electronics Engineering, National Taiwan University, Taipei 10617, Taiwan (China); Liu, C. W., E-mail: chee@cc.ee.ntu.edu.tw [Department of Electrical Engineering, Graduate Institute of Photonics and Optoelectronics, National Taiwan University, Taipei 10617, Taiwan (China); Department of Electrical Engineering, Graduate Institute of Electronics Engineering, National Taiwan University, Taipei 10617, Taiwan (China); National Nano Device Labs, Hsinchu 30077, Taiwan (China); Huang, Yi-Chiau; Chung, Hua; Chang, Chorng-Ping [Applied Materials Inc., Sunnyvale, California 94085 (United States)

    2016-08-29

    Ge/strained GeSn/Ge quantum wells are grown on a 300 mm Si substrate by chemical vapor deposition. The direct bandgap emission from strained GeSn is observed in the photoluminescence spectra and is enhanced by Al{sub 2}O{sub 3}/SiO{sub 2} passivation due to the field effect. The electroluminescence of the direct bandgap emission of strained GeSn is also observed from the Ni/Al{sub 2}O{sub 3}/GeSn metal-insulator-semiconductor tunneling diodes. Electroluminescence is a good indicator of GeSn material quality, since defects in GeSn layers degrade the electroluminescence intensity significantly. At the accumulation bias, the holes in the Ni gate electrode tunnel to the strained n-type GeSn layer through the ultrathin Al{sub 2}O{sub 3} and recombine radiatively with electrons. The emission wavelength of photoluminescence and electroluminescence can be tuned by the Sn content.

  16. Costs of medically assisted reproduction treatment at specialized fertility clinics in the Danish public health care system

    DEFF Research Database (Denmark)

    Christiansen, Terkel; Erb, Karin; Rizvanovic, Amra

    2014-01-01

    To examine the costs to the public health care system of couples in medically assisted reproduction.......To examine the costs to the public health care system of couples in medically assisted reproduction....

  17. Evaluation of faciocutaneous clues to systemic diseases: A learning module for Chinese undergraduate medical students

    Directory of Open Access Journals (Sweden)

    Zhu Shen

    2016-06-01

    Conclusion: Introducing this additional learning module may offer an early opportunity to explore systemic diseases from a dermatological view and is likely to lay the foundations for interdisciplinary collaboration in the future practice for medical students.

  18. MODERNIZATION OF RUSSIAN HEALT PROTECTION SYSTEM SOLVES THE PROBLEM OF RENDERING QUALITY MEDICAL AID TO POPULATION

    Directory of Open Access Journals (Sweden)

    V. A. Alexeev

    2011-01-01

    Full Text Available Last two dozen years, permanent growth of death rate and decrease birth rate take place in Russia. To great extent, this is owing to inadequate health protection system. The practice of personal payments for medical services in amounts unattainable for overwhelming majority of thepopulation grows. RF President’s Administration sets an example: cardiologist’s advice in their clinics costs 40 times more that according to obligatory medical insurance rates. 84% of the country citizens do not approve this approach and consider it socially unjust. An important national project aimed at modernization of the health protection system started in 2011. Non-private medical establishments are to be equipped with up-to-date equipment, modern information systems and medical service standards based on CRM system adopted in developed countries; salaries of health personnel are to be increased.

  19. systemic objective test in medical biochemistry part 1- metabolism

    African Journals Online (AJOL)

    IICBA01

    and help to develop the imagination and the research. ... introduce STFQs, SMCQs, SSQs, SSQs, ASQs, and SCQs as examples of the systemic ... Asking questions lies on the basic foundation of communication, especially the lecturer- .... Systemic True/False Questions are well suited for testing students' comprehension,.

  20. 75 FR 47318 - GE Asset Management Incorporated and GE Investment Distributors, Inc.; Notice of Application and...

    Science.gov (United States)

    2010-08-05

    ...] GE Asset Management Incorporated and GE Investment Distributors, Inc.; Notice of Application and.... Applicants: GE Asset Management Incorporated (``GEAM'') and GE Investment Distributors, Inc. (``GEID... of Investment Management, Office of Investment Company Regulation). SUPPLEMENTARY INFORMATION: The...

  1. Bandwidth Efficient Overlapped FSK Coded Secure Command Transmission for Medical Implant Communication Systems

    Directory of Open Access Journals (Sweden)

    Selman KULAÇ

    2018-06-01

    Full Text Available Nowadays, wireless communication systems are exploited in most health care systems. Implantable Medical Systems (IMS also have wireless communication capability. However, it is very important that secure wireless communication should be provided in terms of both patient rights and patient health. Therefore, wireless transmission systems of IMS should also be robust against to eavesdroppers and adversaries. In this study, a specific overlapped and coded frequency shift keying (FSK modulation technique is developed and security containing with low complexity is provided by this proposed technique. The developed method is suitable for wireless implantable medical systems since it provides low complexity and security as well as bandwidth efficiency.

  2. Homogeneity of Ge-rich nanostructures as characterized by chemical etching and transmission electron microscopy.

    Science.gov (United States)

    Bollani, Monica; Chrastina, Daniel; Montuori, Valeria; Terziotti, Daniela; Bonera, Emiliano; Vanacore, Giovanni M; Tagliaferri, Alberto; Sordan, Roman; Spinella, Corrado; Nicotra, Giuseppe

    2012-02-03

    The extension of SiGe technology towards new electronic and optoelectronic applications on the Si platform requires that Ge-rich nanostructures be obtained in a well-controlled manner. Ge deposition on Si substrates usually creates SiGe nanostructures with relatively low and inhomogeneous Ge content. We have realized SiGe nanostructures with a very high (up to 90%) Ge content. Using substrate patterning, a regular array of nanostructures is obtained. We report that electron microscopy reveals an abrupt change in Ge content of about 20% between the filled pit and the island, which has not been observed in other Ge island systems. Dislocations are mainly found within the filled pit and only rarely in the island. Selective chemical etching and electron energy-loss spectroscopy reveal that the island itself is homogeneous. These Ge-rich islands are possible candidates for electronic applications requiring locally induced stress, and optoelectronic applications which exploit the Ge-like band structure of Ge-rich SiGe.

  3. Homogeneity of Ge-rich nanostructures as characterized by chemical etching and transmission electron microscopy

    International Nuclear Information System (INIS)

    Bollani, Monica; Chrastina, Daniel; Montuori, Valeria; Vanacore, Giovanni M; Tagliaferri, Alberto; Sordan, Roman; Terziotti, Daniela; Bonera, Emiliano; Spinella, Corrado; Nicotra, Giuseppe

    2012-01-01

    The extension of SiGe technology towards new electronic and optoelectronic applications on the Si platform requires that Ge-rich nanostructures be obtained in a well-controlled manner. Ge deposition on Si substrates usually creates SiGe nanostructures with relatively low and inhomogeneous Ge content. We have realized SiGe nanostructures with a very high (up to 90%) Ge content. Using substrate patterning, a regular array of nanostructures is obtained. We report that electron microscopy reveals an abrupt change in Ge content of about 20% between the filled pit and the island, which has not been observed in other Ge island systems. Dislocations are mainly found within the filled pit and only rarely in the island. Selective chemical etching and electron energy-loss spectroscopy reveal that the island itself is homogeneous. These Ge-rich islands are possible candidates for electronic applications requiring locally induced stress, and optoelectronic applications which exploit the Ge-like band structure of Ge-rich SiGe. (paper)

  4. Association between medication supplies and healthcare costs in older adults from an urban healthcare system.

    Science.gov (United States)

    Stroupe, K T; Murray, M D; Stump, T E; Callahan, C M

    2000-07-01

    The amount of medication dispensed to older adults for the treatment of chronic disease must be balanced carefully. Insufficient medication supplies lead to inadequate treatment of chronic disease, whereas excessive supplies represent wasted resources and the potential for toxicity. We used an electronic medical record system to determine the distribution of medications supplied to older urban adults and to examine the correlations of these distributions with healthcare costs and use. A cross-sectional study using data acquired over 3 years (1994-1996). A tax-supported urban public healthcare system consisting of a 300-bed hospital, an emergency department, and a network of community-based ambulatory care centers. Patients were >60 years of age and had at least one prescription refill and at least two ambulatory visits or one hospitalization during the 3-year period. Focusing on 12 major categories of drugs used to treat chronic diseases, we determined the amounts and direct costs of these medications dispensed to older adult patients. Amounts of medications that were needed by patients to medicate themselves adequately were compared with the medication supply actually dispensed considering all sources of care (primary, emergency, and inpatient). We calculated the excess drug costs attributable to oversupply of medication (>120% of the amount needed) and the drug cost reduction caused by undersupply of medication (120% of the supply needed. The total direct cost of targeted medications for 3 years was $1.96 million or, on average, $654,000 annually. During the 3-year period, patients receiving >120% of their needed medications had excess direct medication costs of $279,084 or $144 per patient, whereas patients receiving <80% of drugs needed had reduced medication costs of $423,438 or $634 per patient. Multivariable analyses revealed that both under- and over-supplies of medication were associated with a greater likelihood of emergency department visits and hospital

  5. Automated drug dispensing system reduces medication errors in an intensive care setting.

    Science.gov (United States)

    Chapuis, Claire; Roustit, Matthieu; Bal, Gaëlle; Schwebel, Carole; Pansu, Pascal; David-Tchouda, Sandra; Foroni, Luc; Calop, Jean; Timsit, Jean-François; Allenet, Benoît; Bosson, Jean-Luc; Bedouch, Pierrick

    2010-12-01

    We aimed to assess the impact of an automated dispensing system on the incidence of medication errors related to picking, preparation, and administration of drugs in a medical intensive care unit. We also evaluated the clinical significance of such errors and user satisfaction. Preintervention and postintervention study involving a control and an intervention medical intensive care unit. Two medical intensive care units in the same department of a 2,000-bed university hospital. Adult medical intensive care patients. After a 2-month observation period, we implemented an automated dispensing system in one of the units (study unit) chosen randomly, with the other unit being the control. The overall error rate was expressed as a percentage of total opportunities for error. The severity of errors was classified according to National Coordinating Council for Medication Error Reporting and Prevention categories by an expert committee. User satisfaction was assessed through self-administered questionnaires completed by nurses. A total of 1,476 medications for 115 patients were observed. After automated dispensing system implementation, we observed a reduced percentage of total opportunities for error in the study compared to the control unit (13.5% and 18.6%, respectively; perror (20.4% and 13.5%; perror showed a significant impact of the automated dispensing system in reducing preparation errors (perrors caused no harm (National Coordinating Council for Medication Error Reporting and Prevention category C). The automated dispensing system did not reduce errors causing harm. Finally, the mean for working conditions improved from 1.0±0.8 to 2.5±0.8 on the four-point Likert scale. The implementation of an automated dispensing system reduced overall medication errors related to picking, preparation, and administration of drugs in the intensive care unit. Furthermore, most nurses favored the new drug dispensation organization.

  6. Human-centered design of the human-system interfaces of medical equipment: thyroid uptake system

    International Nuclear Information System (INIS)

    Monteiro, Jonathan K.R.; Farias, Marcos S.; Santos, Isaac J.A. Luquetti; Monteiro, Beany G.

    2013-01-01

    Technology plays an important role in modern medical centers, making healthcare increasingly complex, relying on complex technical equipment. This technical complexity is particularly noticeable in the nuclear medicine. Poorly design human-system interfaces can increase the risks for human error. The human-centered approach emphasizes the development of the equipment with a deep understanding of the users activities, current work practices, needs and abilities of the users. An important concept of human-centered design is that the ease-of-use of the equipment can be ensured only if users are actively incorporated in all phases of the life cycle of design process. Representative groups of users are exposed to the equipment at various stages in development, in a variety of testing, evaluation and interviewing situations. The users feedback obtained is then used to refine the design, with the result serving as input to the next interaction of design process. The limits of the approach are that the users cannot address any particular future needs without prior experience or knowledge about the equipment operation. The aim of this paper is to present a methodological framework that contributes to the design of the human-system interfaces, through an approach related to the users and their activities. A case study is described in which the methodological framework is being applied in development of new human-system interfaces of the thyroid uptake system. (author)

  7. Occupational Exposure to Antineoplastic Drugs: Identification of Job Categories Potentially Exposed throughout the Hospital Medication System

    Directory of Open Access Journals (Sweden)

    Chun-Yip Hon

    2011-09-01

    Conclusion: We found drug contamination on select surfaces at every stage of the medication system, which indicates the existence of an exposure potential throughout the facility. Our results suggest that a broader range of workers are potentially exposed than has been previously examined. These results will allow us to develop a more inclusive exposure assessment encompassing all healthcare workers that are at risk throughout the hospital medication system.

  8. Comparison of medication safety systems in critical access hospitals: Combined analysis of two studies.

    Science.gov (United States)

    Cochran, Gary L; Barrett, Ryan S; Horn, Susan D

    2016-08-01

    The role of pharmacist transcription, onsite pharmacist dispensing, use of automated dispensing cabinets (ADCs), nurse-nurse double checks, or barcode-assisted medication administration (BCMA) in reducing medication error rates in critical access hospitals (CAHs) was evaluated. Investigators used the practice-based evidence methodology to identify predictors of medication errors in 12 Nebraska CAHs. Detailed information about each medication administered was recorded through direct observation. Errors were identified by comparing the observed medication administered with the physician's order. Chi-square analysis and Fisher's exact test were used to measure differences between groups of medication-dispensing procedures. Nurses observed 6497 medications being administered to 1374 patients. The overall error rate was 1.2%. The transcription error rates for orders transcribed by an onsite pharmacist were slightly lower than for orders transcribed by a telepharmacy service (0.10% and 0.33%, respectively). Fewer dispensing errors occurred when medications were dispensed by an onsite pharmacist versus any other method of medication acquisition (0.10% versus 0.44%, p = 0.0085). The rates of dispensing errors for medications that were retrieved from a single-cell ADC (0.19%), a multicell ADC (0.45%), or a drug closet or general supply (0.77%) did not differ significantly. BCMA was associated with a higher proportion of dispensing and administration errors intercepted before reaching the patient (66.7%) compared with either manual double checks (10%) or no BCMA or double check (30.4%) of the medication before administration (p = 0.0167). Onsite pharmacist dispensing and BCMA were associated with fewer medication errors and are important components of a medication safety strategy in CAHs. Copyright © 2016 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  9. Clinical diagnostic system using a small cyclotron for medical use

    International Nuclear Information System (INIS)

    Yonekura, Y.; Magata, Y.; Konishi, J.

    1990-01-01

    Since a small cyclotron and a positron emission tomography (PET) scanner have been installed at the Kyoto University Hospital in 1983, a great deal of effort has been directed to the clinical application of the PET-cyclotron system. This paper outlines the experience with PET in the clinical setting, including the facility, equipments and staff involved, weekly schedule, typical clinical protocols, and some results from the patients. The system consists of small cyclotron for production of the short-lived positron emitting radionuclides, fully automated synthesis system for labeling various compounds, scanning for measurement of radioactivities, and data analysis system for calculating physiological parameters. A resolving cylinder target system with eight smaller cylinders is equipped for production of C-11, N-13, O-15, and F-18. Labeled compounds are quickly delivered to the PET scanner room by two systems--the continuous delivery system for the labeled gas and the rapid delivery system for the liquid compounds by compressed air. A PET scanner devoted for clinical studies is a multislice whole-body PET scanner. Ten PET studies are performed weekly on the average for measuring blood flow and oxygen and glucose metabolism in the brain, blood flow and glucose and fatty acid metabolism in the heart, blood flow and amino acid uptake in the pancreas, lung ventilation, and tumor glucose metabolism. The availability of PET-cyclotron system is still limited in view of cost. The previous clinical studies suggest the contribution of PET to the the understanding of the mechanism of disease pathophysiology. (N.K.)

  10. Effect of the new rural cooperative medical system on farmers’ medical service needs and utilization in Ningbo, China

    Directory of Open Access Journals (Sweden)

    Jianhua Chen

    2016-10-01

    Full Text Available Abstract Background Many countries are developing health mechanisms to pursue the goal of universal coverage. In China, a rural health insurance system entitled New Cooperative Medical System (NCMS has being developed since 2003. This paper aims to explore the changes in the health service needs and utilization among rural residents in Ningbo, China after the implementation of the new rural cooperative medical system (NCMS, and provide evidence to further improve the strategies of NCMS in China. Methods Stratified multistage cluster sampling was used to randomly select 10 villages from 5 townships in Yuyao and Fenghua counties of Ningbo Municipality. Eighty families were selected from each village, and face-to-face interviews were conducted by trained investigators to collect data using questionnaires. Results The two-week visiting rate and prevalence of chronic diseases among the farmers included in the study was 25.40 and 22.50 %, respectively, which were higher than the levels in 2003 and 2008. The rate of not visiting the healthcare facility amongst those with illness, and the rate of non- hospitalization amongst those who required it were 32.36 and 0.60 %, respectively, which was lower than the levels in 2003 and 2008. Most of the outpatient visits were to the village clinics, while the hospitalizations were mainly to county hospitals. Conclusion NCMS greatly affected the utilization of healthcare services from outpatient clinics and improved the hospitalization rate in county hospitals. Financial difficulties are not the major causes of non-hospitalization and non-visiting any longer. These findings suggest that the NCMS policies alleviated the medical burdens of farmers in a certain degree.

  11. Effect of the new rural cooperative medical system on farmers' medical service needs and utilization in Ningbo, China.

    Science.gov (United States)

    Chen, Jianhua; Yu, Hai; Dong, Hengjin

    2016-10-20

    Many countries are developing health mechanisms to pursue the goal of universal coverage. In China, a rural health insurance system entitled New Cooperative Medical System (NCMS) has being developed since 2003. This paper aims to explore the changes in the health service needs and utilization among rural residents in Ningbo, China after the implementation of the new rural cooperative medical system (NCMS), and provide evidence to further improve the strategies of NCMS in China. Stratified multistage cluster sampling was used to randomly select 10 villages from 5 townships in Yuyao and Fenghua counties of Ningbo Municipality. Eighty families were selected from each village, and face-to-face interviews were conducted by trained investigators to collect data using questionnaires. The two-week visiting rate and prevalence of chronic diseases among the farmers included in the study was 25.40 and 22.50 %, respectively, which were higher than the levels in 2003 and 2008. The rate of not visiting the healthcare facility amongst those with illness, and the rate of non- hospitalization amongst those who required it were 32.36 and 0.60 %, respectively, which was lower than the levels in 2003 and 2008. Most of the outpatient visits were to the village clinics, while the hospitalizations were mainly to county hospitals. NCMS greatly affected the utilization of healthcare services from outpatient clinics and improved the hospitalization rate in county hospitals. Financial difficulties are not the major causes of non-hospitalization and non-visiting any longer. These findings suggest that the NCMS policies alleviated the medical burdens of farmers in a certain degree.

  12. [Impact of an automated dispensing system for medical devices in cardiac surgery department].

    Science.gov (United States)

    Clou, E; Dompnier, M; Kably, B; Leplay, C; Poupon, E; Archer, V; Paul, M

    2018-01-01

    To secure medical devices' management, the implementation of automated dispensing system in surgical service has been realized. The objective of this study was to evaluate security, organizational and economic impact of installing automated dispensing system for medical devices (ASDM). The implementation took place in a cardiac surgery department. Security impact was assessed by comparing traceability rate of implantable medical devices one year before and one year after installation. Questionnaire on nurses' perception and satisfaction completed this survey. Resupplying costs, stocks' evolution and investments for the implementation of ASDM were the subject of cost-benefit study. After one year, traceability rate is excellent (100%). Nursing staffs were satisfied with 87.5% by this new system. The introduction of ASDM allowed a qualitative and quantitative decrease in stocks, with a reduction of 30% for purchased medical devices and 15% for implantable medical devices in deposit-consignment. Cost-benefit analysis shows a rapid return on investment. Real stock decrease (purchased medical devices) is equivalent to 46.6% of investment. Implementation of ASDM allows to secure storage and dispensing of medical devices. This system has also an important economic impact and appreciated by users. Copyright © 2017 Académie Nationale de Pharmacie. Published by Elsevier Masson SAS. All rights reserved.

  13. [Current situations and problems of quality control for medical imaging display systems].

    Science.gov (United States)

    Shibutani, Takayuki; Setojima, Tsuyoshi; Ueda, Katsumi; Takada, Katsumi; Okuno, Teiichi; Onoguchi, Masahisa; Nakajima, Tadashi; Fujisawa, Ichiro

    2015-04-01

    Diagnostic imaging has been shifted rapidly from film to monitor diagnostic. Consequently, Japan medical imaging and radiological systems industries association (JIRA) have recommended methods of quality control (QC) for medical imaging display systems. However, in spite of its need by majority of people, executing rate is low. The purpose of this study was to validate the problem including check items about QC for medical imaging display systems. We performed acceptance test of medical imaging display monitors based on Japanese engineering standards of radiological apparatus (JESRA) X-0093*A-2005 to 2009, and performed constancy test based on JESRA X-0093*A-2010 from 2010 to 2012. Furthermore, we investigated the cause of trouble and repaired number. Medical imaging display monitors had 23 inappropriate monitors about visual estimation, and all these monitors were not criteria of JESRA about luminance uniformity. Max luminance was significantly lower year-by-year about measurement estimation, and the 29 monitors did not meet the criteria of JESRA about luminance deviation. Repaired number of medical imaging display monitors had 25, and the cause was failure liquid crystal panel. We suggested the problems about medical imaging display systems.

  14. An Analysis of Medication Errors at the Military Medical Center: Implications for a Systems Approach for Error Reduction

    National Research Council Canada - National Science Library

    Scheirman, Katherine

    2001-01-01

    An analysis was accomplished of all inpatient medication errors at a military academic medical center during the year 2000, based on the causes of medication errors as described by current research in the field...

  15. Experiences with establishing and implementing learning management system and computer-based test system in medical college.

    Science.gov (United States)

    Park, Joo Hyun; Son, Ji Young; Kim, Sun

    2012-09-01

    The purpose of this study was to establish an e-learning system to support learning in medical education and identify solutions for improving the system. A learning management system (LMS) and computer-based test (CBT) system were established to support e-learning for medical students. A survey of 219 first- and second-grade medical students was administered. The questionnaire included 9 forced choice questions about the usability of system and 2 open-ended questions about necessary improvements to the system. The LMS consisted of a class management, class evaluation, and class attendance system. CBT consisted of a test management, item bank, and authoring tool system. The results of the survey showed a high level of satisfaction in all system usability items except for stability. Further, the advantages of the e-learning system were ensuring information accessibility, providing constant feedback, and designing an intuitive interface. Necessary improvements to the system were stability, user control, readability, and diverse device usage. Based on the findings, suggestions for developing an e-learning system to improve usability by medical students and support learning effectively are recommended.

  16. On Line Service Composition in the Integrated Clinical Environment for eHealth and Medical Systems.

    Science.gov (United States)

    García-Valls, Marisol; Touahria, Imad Eddine

    2017-06-08

    Medical and eHealth systems are progressively realized in the context of standardized architectures that support safety and ease the integration of the heterogeneous (and often proprietary) medical devices and sensors. The Integrated Clinical Environment (ICE) architecture appeared recently with the goal of becoming a common framework for defining the structure of the medical applications as concerns the safe integration of medical devices and sensors. ICE is simply a high level architecture that defines the functional blocks that should be part of a medical system to support interoperability. As a result, the underlying communication backbone is broadly undefined as concerns the enabling software technology (including the middleware) and associated algorithms that meet the ICE requirements of the flexible integration of medical devices and services. Supporting the on line composition of services in a medical system is also not part of ICE; however, supporting this behavior would enable flexible orchestration of functions (e.g., addition and/or removal of services and medical equipment) on the fly. iLandis one of the few software technologies that supports on line service composition and reconfiguration, ensuring time-bounded transitions across different service orchestrations; it supports the design, deployment and on line reconfiguration of applications, which this paper applies to service-based eHealth domains. This paper designs the integration between ICE architecture and iLand middleware to enhance the capabilities of ICE with on line service composition and the time-bounded reconfiguration of medical systems based on distributed services. A prototype implementation of a service-based eHealth system for the remote monitoring of patients is described; it validates the enhanced capacity of ICE to support dynamic reconfiguration of the application services. Results show that the temporal cost of the on line reconfiguration of the eHealth application is bounded

  17. The evolution of the Japanese medical education system: a historical perspective.

    Science.gov (United States)

    Kuwabara, Norimitsu; Yamashita, Miu; Yee, Keolamau; Kurahara, David

    2015-03-01

    The Japanese Medical Education system has been influenced by political events throughout the country's history. From long periods of isolation from the western world to the effect of world wars, Japan's training system for physicians has had to adapt in many ways and will continue to change. The Japanese medical education system was recently compared to the "Galapagos Islands" for its unusual and singular evolution, in a speech by visiting professor Dr. Gordon L. Noel at the University of Tokyo International Research center.1 Japanese medical schools are currently working to increase their students' clinical hours or else these students may not be able to train in the United States for residencies. Knowing the history of the Japanese Medical education system is paramount to understanding the current system in place today. Studying the historical foundation of this system will also provide insight on how the system must change in order to produce better clinicians. This article provides a glimpse into the medical system of another nation that may encourage needed reflection on the state of current healthcare training in the United States.

  18. Outpatients flow management and ophthalmic electronic medical records system in university hospital using Yahgee Document View.

    Science.gov (United States)

    Matsuo, Toshihiko; Gochi, Akira; Hirakawa, Tsuyoshi; Ito, Tadashi; Kohno, Yoshihisa

    2010-10-01

    General electronic medical records systems remain insufficient for ophthalmology outpatient clinics from the viewpoint of dealing with many ophthalmic examinations and images in a large number of patients. Filing systems for documents and images by Yahgee Document View (Yahgee, Inc.) were introduced on the platform of general electronic medical records system (Fujitsu, Inc.). Outpatients flow management system and electronic medical records system for ophthalmology were constructed. All images from ophthalmic appliances were transported to Yahgee Image by the MaxFile gateway system (P4 Medic, Inc.). The flow of outpatients going through examinations such as visual acuity testing were monitored by the list "Ophthalmology Outpatients List" by Yahgee Workflow in addition to the list "Patients Reception List" by Fujitsu. Patients' identification number was scanned with bar code readers attached to ophthalmic appliances. Dual monitors were placed in doctors' rooms to show Fujitsu Medical Records on the left-hand monitor and ophthalmic charts of Yahgee Document on the right-hand monitor. The data of manually-inputted visual acuity, automatically-exported autorefractometry and non-contact tonometry on a new template, MaxFile ED, were again automatically transported to designated boxes on ophthalmic charts of Yahgee Document. Images such as fundus photographs, fluorescein angiograms, optical coherence tomographic and ultrasound scans were viewed by Yahgee Image, and were copy-and-pasted to assigned boxes on the ophthalmic charts. Ordering such as appointments, drug prescription, fees and diagnoses input, central laboratory tests, surgical theater and ward room reservations were placed by functions of the Fujitsu electronic medical records system. The combination of the Fujitsu electronic medical records and Yahgee Document View systems enabled the University Hospital to examine the same number of outpatients as prior to the implementation of the computerized filing system.

  19. A ring transducer system for medical ultrasound research.

    Science.gov (United States)

    Waag, Robert C; Fedewa, Russell J

    2006-10-01

    An ultrasonic ring transducer system has been developed for experimental studies of scattering and imaging. The transducer consists of 2048 rectangular elements with a 2.5-MHz center frequency, a 67% -6 dB bandwidth, and a 0.23-mm pitch arranged in a 150-mm-diameter ring with a 25-mm elevation. At the center frequency, the element size is 0.30lambda x 42lambda and the pitch is 0.38lambda. The system has 128 parallel transmit channels, 16 parallel receive channels, a 2048:128 transmit multiplexer, a 2048:16 receive multiplexer, independently programmable transmit waveforms with 8-bit resolution, and receive amplifiers with time variable gain independently programmable over a 40-dB range. Receive signals are sampled at 20 MHz with 12-bit resolution. Arbitrary transmit and receive apertures can be synthesized. Calibration software minimizes system nonidealities caused by noncircularity of the ring and element-to-element response differences. Application software enables the system to be used by specification of high-level parameters in control files from which low-level hardware-dependent parameters are derived by specialized code. Use of the system is illustrated by producing focused and steered beams, synthesizing a spatially limited plane wave, measuring angular scattering, and forming b-scan images.

  20. Ge-Au eutectic bonding of Ge (100) single crystals

    International Nuclear Information System (INIS)

    Knowlton, W.B.; Beeman, J.W.; Emes, J.H.; Loretto, D.; Itoh, K.M.; Haller, E.E.

    1993-01-01

    The author present preliminary results on the eutectic bonding between two (100) Ge single crystal surfaces using thin films of Au ranging from 900 angstrom/surface to 300 angstrom/surface and Pd (10% the thickness of Au). Following bonding, plan view optical microscopy (OM) of the cleaved interface of samples with Au thicknesses ≤ 500 angstrom/surface show a eutectic morphology more conducive to phonon transmission through the bond interface. High resolution transmission electron microscopy (HRTEM) cross sectional interface studies of a 300 angstrom/surface Au sample show epitaxial growth of Ge. In sections of the bond, lattice continuity of the Ge is apparent through the interface. TEM studies also reveal heteroepitaxial growth of Au with a Au-Ge lattice mismatch of less than 2%. Eutectic bonds with 200 angstrom/surface Au have been attained with characterization pending. An optical polishing technique for Ge has been optimized to insure intimate contact between the Ge surfaces prior to bonding. Interferometry analysis of the optically polished Ge surface shows that surface height fluctuations lie within ±150 angstrom across an interval of lmm. Characterization of phonon transmission through the interface is discussed with respect to low temperature detection of ballistic phonons