WorldWideScience

Sample records for gated spet myocardial

  1. A realistic 3-D gated cardiac phantom for quality control of gated myocardial perfusion SPET: the Amsterdam gated (AGATE) cardiac phantom

    NARCIS (Netherlands)

    Visser, Jacco J. N.; Sokole, Ellinor Busemann; Verberne, Hein J.; Habraken, Jan B. A.; van de Stadt, Huybert J. F.; Jaspers, Joris E. N.; Shehata, Morgan; Heeman, Paul M.; van Eck-Smit, Berthe L. F.

    2004-01-01

    A realistic 3-D gated cardiac phantom with known left ventricular (LV) volumes and ejection fractions (EFs) was produced to evaluate quantitative measurements obtained from gated myocardial single-photon emission tomography (SPET). The 3-D gated cardiac phantom was designed and constructed to fit

  2. Assessment of left ventricular diastolic function from quantitative electrocardiographic-gated {sup 99m}Tc-tetrofosmin myocardial SPET

    Energy Technology Data Exchange (ETDEWEB)

    Kikkawa, M.; Nakamura, T.; Sugihara, H.; Okuyama, C.; Ushijima, Y.; Nishimura, T. [Kyoto Prefectural Univ. of Medicine (Japan). Dept. of Radiology; Sakamoto, K.; Azuma, A.; Sawada, T. [Kyoto Prefectural Univ. of Medicine (Japan). Second Dept. of Medicine

    2001-05-01

    We have developed new software which can evaluate left ventricular (LV) diastolic functional parameters from a quantitative gated SPET (QGS) program. To examine its accuracy, we compared these findings with the LV diastolic functional indices obtained from gated radionuclide ventriculography (RNV). Twenty-four patients were selected for this study. Gated SPET with technetium-99m tetrofosmin was performed and the QGS program was used with a temporal resolution of 32 frames per R-R interval. The LV volume of each frame was calculated and four harmonics of Fourier series were retained for the analysis of the LV volume curve. From this fitted curve and its first derivative curve, we derived LV systolic functional indices, e.g. ejection fraction (EF), peak ejection rate (PER) and time to PER (TPER), as well as LV diastolic functional variables, e.g. 1/3 filling fraction (1/3 FF), peak filling rate (PFR) and time to PFR (TPFR). Within 5{+-}2 days, gated RNV was performed and diastolic functional parameters were determined by the same method. No significant difference was observed between the variables calculated by gated SPET and by gated RNV. There was a good correlation between EF, PER, TPER, 1/3 FF, PFR and TPFR determined by these two methods (EF: r=0.95, P<0.0001; PER: r=0.87, P<0.0001; TPER: r=0.84, P<0.0001; 1/3 FF: r=0.87, P<0.0001; PFR: r=0.92, P<0.0001; TPFR: r=0.89, P<0.0001). Bland-Altman plots did not reveal any significant degree of directional measurement bias in any of the comparisons of gated SPET data and RNV data. It is concluded that, in addition to the conventional LV systolic functional indices, our program accurately provides LV diastolic functional parameters from gated SPET. Also, this program will be useful for detecting LV diastolic dysfunction in various cardiac diseases before LV systolic dysfunction becomes evident. (orig.)

  3. Effect of beta-blockade on low-dose dobutamine-induced changes in left ventricular function in healthy volunteers: assessment by gated SPET myocardial perfusion scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Everaert, H.; Vanhove, C.; Franken, P.R. [Division of Nuclear Medicine, University Hospital, Free University of Brussels (AZ VUB), Brussels (Belgium)

    2000-04-01

    Viability studies are often performed in patients receiving beta-blocking agents. However, the intake of beta-blocking agents could influence the identification of viable myocardium when low-dose dobutamine is used to demonstrate inotropic reserve. The aim of this study was to quantify the effect of beta-blockade on global and regional left ventricular function in healthy volunteers using low-dose dobutamine gated single-photon emission tomographic (SPET) myocardial perfusion scintigraphy. Ten subjects were studied once ''on'' and once ''off'' beta-blocker therapy (metoprolol succinate, 100 mg day{sup -1}). On each occasion four consecutive gated SPET acquisitions (of 7 min duration) were recorded after injection of 925 MBq technetium-99m tetrofosmin on a triple-headed camera equipped with focussing (Cardiofocal) collimators. Acquisitions were made at rest (baseline 1 and 2) and 5 min after the beginning of the infusion of 5 and 10 {mu}g kg{sup -1} min{sup -1} dobutamine. Wall thickening (WT) was quantified using a method based on circumferential profile analysis. Left ventricular ejection fraction (LVEF) was obtained using the Cedars-Sinai algorithm. Blood pressure (BP) and heart rate (HR) were recorded at the end of each acquisition. At baseline LVEF, WT and systolic BP values under beta-blockade were not significantly different from those obtained in the non-beta-blocked state. The mean HR and diastolic BP at baseline were lower under beta-blockade. Dobutamine administration (at 5 and 10 {mu}g kg{sup -1} min{sup -1}) induced a significant increase in WT, LVEF and systolic BP in all subjects both on and off beta-blockade. The increases in WT, LVEF and systolic BP in the beta-blocked state were less pronounced but not significantly different. HR increased significantly at 10 {mu}g kg{sup -1} min{sup -1} dobutamine without beta-blocker administration, while no increase in HR was observed in the beta-blocked state. Beta

  4. Age- and gender-specific differences in left ventricular cardiac function and volumes determined by gated SPET

    International Nuclear Information System (INIS)

    Bondt, P. de; Wiele, C. van de; Winter, F. de; Dierckx, R.A.; Sutter, J. de; Backer, G. de

    2001-01-01

    The aim of this study was to determine normative volumetric data and ejection fraction values derived from gated myocardial single-photon emission tomography (SPET) using the commercially available software algorithm QGS (quantitative gated SPET). From a prospective database of 876 consecutive patients who were referred for a 2-day stress-rest technetium-99m tetrofosmin (925 MBq) gated SPET study, 102 patients (43 men, 59 women) with a low (<10%) pre-test likelihood of coronary disease were included (mean age 57.6 years). For stress imaging, a bicycle protocol was used in 79 of the patients and a dipyridamole protocol in 23. Left ventricular ejection fraction (LVEF) and end-diastolic and -systolic volumes (EDV and ESV) were calculated by QGS. EDV and ESV were corrected for body surface area, indicated by EDVi and ESVi. To allow comparison with previous reports using other imaging modalities, men and women were divided into three age groups (<45 years, ≥45 years but <65 years and ≥65 years). Men showed significantly higher EDVi and ESVi values throughout and lower LVEF values when compared with women in the subgroup ≥65 years (P<0.05, ANOVA). Significant negative and positive correlations were found between age and EDVi and ESVi values for both women and men and between LVEF and age in women (Pearson P≤0.01). LVEF values at bicycle stress were significantly higher than at rest (P=0.000, paired t test), which was the result of a significant decrease in ESV (P=0.003), a phenomenon which did not occur following dipyridamole stress (P=0.409). The data presented suggest that LVEF and EDVi and ESVi as assessed by QGS are strongly gender-specific. Although the physiological significance of these results is uncertain and needs further study, these findings demonstrate that the evaluation of cardiac function and volumes of patients by means of QGS should consider age- and gender-matched normative values. (orig.)

  5. Prediction of left ventricular dilatation with thallium-201 SPET imaging after primary angioplasty in patients with acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Joon Young; Moon, Dae Hyuk; Shin, Jung Woo; Lee, Hee Kyung [Department of Nuclear Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea); Lee, Cheol Whan; Park, Seong-Wook; Hong, Myeong-Ki; Song, Jae-Kwan; Park, Seung-Jung [Department of Internal Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea)

    2002-06-01

    Progressive ventricular dilatation is an important prognostic factor in patients with acute myocardial infarction. We evaluated clinical, angiographic, echocardiographic and thallium-201 single-photon emission tomography (SPET) imaging variables predictive of the change in left ventricular volume during a 7-month follow-up period after primary angioplasty in patients with acute myocardial infarction. Thirty-six patients with first acute myocardial infarction treated with primary angioplasty within 12 h of onset underwent {sup 201}Tl SPET imaging (5.8{+-}2.1 days after angioplasty). Changes in left ventricular volume were assessed over the 7-month period. The left ventricle dilated significantly after angioplasty (P<0.001). Multivariate analysis revealed that the number of segments with {sup 201}Tl uptake <40% of peak activity was a single independent predictor of increase in end-diastolic volume index between 1 week and 7 months (R{sup 2}=0.41, P< 0.001). The presence of two or more segments with {sup 201}Tl uptake <40% predicted an increase in end-diastolic volume index of {>=}6 ml/m{sup 2} with positive and negative predictive values of 85% (17/20) and 75% (12/16), respectively. It is concluded that, following primary angioplasty in patients with acute myocardial infarction, the extent of myocardial infarction assessed by {sup 201}Tl SPET can identify those who will develop ventricular dilatation during the subsequent 7 months. (orig.)

  6. Early detection of myocardial ischaemia in the emergency department by rest or exercise 99mTc tracer myocardial SPET in patients with chest pain and non-diagnostic ECG

    International Nuclear Information System (INIS)

    Conti, A.; Paladini, B.; Francois, C.; Grifoni, S.; Berni, G.; Gallini, C.; Costanzo, E.; Ferri, P.; Matteini, M.; Pieroni, C.; Migliorini, A.; Antoniucci, D.

    2001-01-01

    Chest pain (CP) represents a frequent reason for presentation at the emergency department (ED). A large proportion of patients have non-diagnostic ECG on presentation, and in many cases several hours have elapsed since onset of symptoms. Acute rest myocardial scintigraphy (rest SPET) has been shown to have a relevant role in the detection of patients at risk for coronary events, but its sensitivity and negative predictive value are optimal only within the first 3 h following onset of symptoms. In those with delayed presentation, exercise SPET alone, as a screening approach, appears more promising, but its feasibility and diagnostic role in the ED are still unresolved. A total of 231 consecutive patients with a recent-onset (<24 h) first episode of CP had a negative first-line work-up including ECG, troponins, creatine kinase-MB and echocardiography. These patients were considered at low risk for short-term coronary events. Patients were studied with rest SPET if they presented <3 h after onset of CP and exercise SPET if they presented after ≥3 h. The end-points of the study were detection of significant coronary artery disease (CAD) by angiography and major coronary events or cardiac death at 6 months. Eighty patients (35%) underwent rest SPET, while 151 (65%) underwent exercise SPET. Two of the 159 patients with negative SPET had evidence of critical CAD at 6-month follow-up (one patient in the rest SPET group and one in the exercise SPET group; P=NS). Of the 72 patients (31%) with a positive scan, 34 (15%) had documented CAD (16 patients in the rest SPET group and 18 in the exercise SPET group; P=NS). Sensitivity, specificity, accuracy and predictive value were not statistically different between the two groups. In conclusion, the accuracy of exercise SPET in patients with CP and delayed presentation to the ED is comparable to that of validated rest SPET in patients with early presentation. Owing to the high negative predictive value (99%), exercise SPET is

  7. Early detection of myocardial ischaemia in the emergency department by rest or exercise {sup 99m}Tc tracer myocardial SPET in patients with chest pain and non-diagnostic ECG

    Energy Technology Data Exchange (ETDEWEB)

    Conti, A.; Paladini, B.; Francois, C.; Grifoni, S.; Berni, G. [Emergency Dept., Careggi General Hospital, Florence (Italy); Gallini, C.; Costanzo, E.; Ferri, P.; Matteini, M.; Pieroni, C. [Dept. of Nuclear Medicine, Careggi General Hospital, Florence (Italy); Migliorini, A.; Antoniucci, D. [Dept. of Cardiology, Careggi General Hospital, Florence (Italy)

    2001-12-01

    Chest pain (CP) represents a frequent reason for presentation at the emergency department (ED). A large proportion of patients have non-diagnostic ECG on presentation, and in many cases several hours have elapsed since onset of symptoms. Acute rest myocardial scintigraphy (rest SPET) has been shown to have a relevant role in the detection of patients at risk for coronary events, but its sensitivity and negative predictive value are optimal only within the first 3 h following onset of symptoms. In those with delayed presentation, exercise SPET alone, as a screening approach, appears more promising, but its feasibility and diagnostic role in the ED are still unresolved. A total of 231 consecutive patients with a recent-onset (<24 h) first episode of CP had a negative first-line work-up including ECG, troponins, creatine kinase-MB and echocardiography. These patients were considered at low risk for short-term coronary events. Patients were studied with rest SPET if they presented <3 h after onset of CP and exercise SPET if they presented after {>=}3 h. The end-points of the study were detection of significant coronary artery disease (CAD) by angiography and major coronary events or cardiac death at 6 months. Eighty patients (35%) underwent rest SPET, while 151 (65%) underwent exercise SPET. Two of the 159 patients with negative SPET had evidence of critical CAD at 6-month follow-up (one patient in the rest SPET group and one in the exercise SPET group; P=NS). Of the 72 patients (31%) with a positive scan, 34 (15%) had documented CAD (16 patients in the rest SPET group and 18 in the exercise SPET group; P=NS). Sensitivity, specificity, accuracy and predictive value were not statistically different between the two groups. In conclusion, the accuracy of exercise SPET in patients with CP and delayed presentation to the ED is comparable to that of validated rest SPET in patients with early presentation. Owing to the high negative predictive value (99%), exercise SPET is

  8. Exercise gated planar myocardial perfusion imaging using technetium-99m sestamibi for the diagnosis of coronary artery disease: an alternative to exercise tomographic imaging

    International Nuclear Information System (INIS)

    Jamar, F.; Topcuoglu, R.; Cauwe, F.; Coster, P. de; Roelants, V.; Beckers, C.; Wijns, W.; Melin, J.A.

    1995-01-01

    This prospective study was designed to evaluate the diagnostic performance of 99m Tc-sestamibi exercise gated planar myocardial imaging by comparison with both visual and quantitative analyses of SPET. The study was conducted in 115 consecutive patients with known or suspected CAD, including 54 patients with a previous myocardial infarction (MI), referred for exercise testing prior to coronary angiography. Multi-gated planar imaging and SPET were performed after bicycle exercise. The end-diastolic (ED) and SPET images were visually scored (SVi). Myocardial uptake was quantitated on SPET slices using maximum count circumferential profiles (SQu) and defect extent was measured by comparison with gender-matched data sets obtained from 27 controls ( 50% and/or regional wall motion abnormality. The cut-off criteria for positivity of the three procedures were determined from receiver operating characteristic (ROC) curves derived from the data of patients without previous MI. The area under the ROC curves was similar for ED, SVi and SQu. This was confirmed by the analysis of sensitivity performed using the ROC curve-derived cut-off criteria, in patients with or without previous MI. SVi was more sensitive than ED in identifying the diseased vessel(s) (ED: 41% vs SVi: 80%); but ED was more specific in this respect (ED: 79% vs SVi: 61%). (orig.)

  9. Technetium-99m tetrofosmin rest/stress myocardial SPET with a same-day 2-hour protocol: comparison with coronary angiography. A Spanish-Portuguese multicentre clinical trial

    Energy Technology Data Exchange (ETDEWEB)

    Montz, R. [Univ. Complutense, Madrid (Spain); Perez-Castejon, M.J. [Univ. Complutense, Madrid (Spain); Jurado, J.A. [Inst. de Cardiologia, Madrid (Spain); Martin-Comin, J. [Hospital de Bellvitge, Hospitalet de Ll./Barcelona (Spain); Esplugues, E. [Hospital de Bellvitge, Hospitalet de Ll./Barcelona (Spain); Salgado, L. [Hospital de Santa Cruz, Carnaxide (Portugal); Ventosa, A. [Hospital de Santa Cruz, Carnaxide (Portugal); Cantinho, G. [Facultad de Medicina, Hospital Santa Maria, Lisbon (Portugal); Sa, E.P. [Facultad de Medicina, Hospital Santa Maria, Lisbon (Portugal); Fonseca, A.T. [Inst. Portugues de Oncologia (IPOFG), Lisbon (Portugal); Vieira, M.R. [Inst. Portugues de Oncologia (IPOFG), Lisbon (Portugal); Ortiz-Berrocal, J. [Universidad Autonoma de Madrid (Spain). Clinica Puerta de Hierro; Tabuenca, M.J. [Universidad Autonoma de Madrid (Spain). Clinica Puerta de Hierro; Garcia, A. [Hospital Clinico y Provincial, Barcelona (Spain); Magrina, J. [Hospital Clinico y Provincial, Barcelona (Spain); Ortega, D. [Hospital Valle de Hebron, Barcelona (Spain); Puente, C. [Hospital Regional Carlos Haya, Malaga (Spain); Ferrer, A.I. [Hospitals da Universidade, Coimbra (Portugal); Pedrosa, J. [Hospitals da Universidade, Coimbra (Portugal); Latre, J.M. [Hospital Reina Sofia, Cordoba (Spain); Carreras, J.L. [Univ. Complutense, Madrid (Spain)

    1996-06-01

    Technetium-99m tetrofosmin (Myoview) has unique properties for myocardial perfusion imaging very early after injection of the tracer. We used a very short same-day rest/stress protocol, to be performed within 2 h and evaluated its diagnostic accuracy. The study included 144 patients from seven Spanish and four Portuguese centres with a diagnosis of uncomplicated coronary artery disease (CAD); 78 patients (54%) had no history of prior myocardial infarction. Patients were injected with {<=}300 MBq {sup 99m}Tc-tetrofosmin at rest and {<=}900 MBq approximately 1 h later at peak exercise. Single-photon emission tomographic (SPET) acquisitions were initiated within 5-30 min post injection. The results were compared with those of coronary angiography (CA). The data of 142 patients were completely evaluable (two with non-evaluable images were excluded). The quality of rest images was excellent or good in 86%, regionally problematic in 7%, poor but well interpretable in 5% and non-evaluable in 2%. The overall sensitivity for the detection of CAD was 93%, the specificity 38% and the accuracy 85%. The localization of defects by SPET in relation the perfusion territories of stenosed vessels ({>=}=50%) was achieved with a sensitivity of 64% for the left anterior descending artery, 49% for the left circumflex artery and 86% for the right coronary artery, and an accuracy of 71%, 72% and 73% respectively. Concordance of SPET and CA was 62% for single-vessel disease and 68% for multivessel disease. In conclusion, this Spanish-Portuguese multicentre clinical trial confirmed, in a considerable number of patients who underwent coronary angiography, the feasibility of {sup 99m}Tc terofosmin (Myoview) rest/stress myocardial SPET using a very short protocol (2 h). (orig.)

  10. Technetium-99m tetrofosmin rest/stress myocardial SPET with a same-day 2-hour protocol: comparison with coronary angiography. A Spanish-Portuguese multicentre clinical trial

    International Nuclear Information System (INIS)

    Montz, R.; Perez-Castejon, M.J.; Jurado, J.A.; Martin-Comin, J.; Esplugues, E.; Salgado, L.; Ventosa, A.; Cantinho, G.; Sa, E.P.; Fonseca, A.T.; Vieira, M.R.; Ortiz-Berrocal, J.; Magrina, J.; Ortega, D.; Puente, C.; Ferrer, A.I.; Pedrosa, J.; Latre, J.M.; Carreras, J.L.

    1996-01-01

    Technetium-99m tetrofosmin (Myoview) has unique properties for myocardial perfusion imaging very early after injection of the tracer. We used a very short same-day rest/stress protocol, to be performed within 2 h and evaluated its diagnostic accuracy. The study included 144 patients from seven Spanish and four Portuguese centres with a diagnosis of uncomplicated coronary artery disease (CAD); 78 patients (54%) had no history of prior myocardial infarction. Patients were injected with ≤300 MBq 99m Tc-tetrofosmin at rest and ≤900 MBq approximately 1 h later at peak exercise. Single-photon emission tomographic (SPET) acquisitions were initiated within 5-30 min post injection. The results were compared with those of coronary angiography (CA). The data of 142 patients were completely evaluable (two with non-evaluable images were excluded). The quality of rest images was excellent or good in 86%, regionally problematic in 7%, poor but well interpretable in 5% and non-evaluable in 2%. The overall sensitivity for the detection of CAD was 93%, the specificity 38% and the accuracy 85%. The localization of defects by SPET in relation the perfusion territories of stenosed vessels (≥=50%) was achieved with a sensitivity of 64% for the left anterior descending artery, 49% for the left circumflex artery and 86% for the right coronary artery, and an accuracy of 71%, 72% and 73% respectively. Concordance of SPET and CA was 62% for single-vessel disease and 68% for multivessel disease. In conclusion, this Spanish-Portuguese multicentre clinical trial confirmed, in a considerable number of patients who underwent coronary angiography, the feasibility of 99m Tc terofosmin (Myoview) rest/stress myocardial SPET using a very short protocol (2 h). (orig.)

  11. Assessment of left ventricular diastolic function by gated single-photon emission tomography: comparison with Doppler echocardiography

    International Nuclear Information System (INIS)

    Yamano, Tetsuhiro; Sakamoto, Kenzo; Hikosaka, Takato; Zen, Kan; Nakamura, Takeshi; Sawada, Takahisa; Azuma, Akihiro; Nakagawa, Masao; Nakamura, Tomoki; Nishimura, Tsunehiko

    2003-01-01

    Gated single-photon emission tomography (SPET) is not yet an established procedure for the evaluation of left ventricular (LV) diastolic function. This study examined diastolic function derived from gated SPET in comparison with an established diagnostic tool, Doppler echocardiography. We examined 37 consecutive patients with normal sinus rhythm who underwent gated technetium-99m tetrofosmin SPET. A gated SPET program was used with a temporal resolution of 32 frames per R-R interval. We obtained the Doppler transmitral flow velocity waveform immediately before gated SPET image acquisition. Patients who showed a ratio of peak early transmitral flow velocity to atrial flow velocity (E/A) of >1 or whose R-R intervals differed by >5% between Doppler echocardiography and gated SPET were excluded from this investigation. We compared diastolic indices and presumed corresponding intervals in diastole using the two methods. The peak filling rate (PFR) derived from gated SPET correlated with the Doppler peak velocity of the early transmitral flow (E) wave (r=0.65) and deceleration of the E wave (r=0.71). The time to PFR and percent atrial contribution to LV filling from gated SPET correlated excellently with the Doppler LV isovolumic relaxation time (r=0.93) and the E/A ratio (r=-0.85), respectively. There was a significant linear correlation in all the intervals from the R wave to the presumed corresponding diastolic points. The point of PFR in gated SPET and the peak of the E wave in Doppler echocardiography generally coincided. The onset of filling in gated SPET tended to be closer to the second heart sound than the start of the E wave in Doppler echocardiography. We conclude that gated SPET permits the assessment of not only myocardial perfusion and LV systolic function but also diastolic function, although there may be some errors in detection of the precise beginning of LV filling. (orig.)

  12. Effects of low-dose dobutamine on left ventricular function in normal subjects as assessed by gated single-photon emission tomography myocardial perfusion studies

    Energy Technology Data Exchange (ETDEWEB)

    Everaert, H.; Vanhove, C.; Franken, P.R. [Div. of Nuclear Medicine, University Hospital, Free University of Brussels (Belgium)

    1999-10-01

    Electrocardiography gated single-photon emission tomography (gated SPET) allows the assessment of regional perfusion and function simultaneously and in full spatial congruency. In this study changes in global and regional left ventricular function in response to dobutamine infusion were assessed in ten healthy volunteers using sequential gated SPET myocardial perfusion acquisitions. Four consecutive gated SPET images were recorded 60 min after injection of 925 MBq technetium-99m tetrofosmin on a three-head camera equipped with focussing collimators. Two acquisitions were made at rest (baseline 1 and 2), and the third and fourth acquisitions were started 5 min after the beginning of the infusion of 5 and 10 {mu}g kg{sup -1} min{sup -1} dobutamine, respectively. Systolic wall thickening (WT) was quantified using a method based on circumferential profile analysis. Left ventricular ejection fraction (LVEF) and volumes were calculated automatically using the Cedars-Sinai program. Nine of the ten subjects presented a definite increase in WT during dobutamine infusion. WT increased on average from 46%{+-}14% at baseline to 71%{+-}23% (range: 37%-106%; P<0.05) during 5 {mu}g kg{sup -1} min{sup -1} dobutamine infusion and to 85%{+-}25% (range: 62%-123%; P<0.05 with respect to WT at 5 {mu}g kg{sup -1} min{sup -1}) during 10 {mu}g kg{sup -1} min{sup -1} dobutamine infusion. Apical segments showed the largest WT at baseline. The average WT response to dobutamine was similar for all parts of the myocardium. It is concluded that changes in WT induced by infusion of low-dose dobutamine can be assessed by sequential gated SPET myocardial perfusion studies. The ''stress gated SPET'' protocol proposed in this study might be helpful to distinguish viable from scar tissue in patients with coronary artery disease, by demonstrating a preserved inotropic response in hypoperfused myocardium. (orig.)

  13. Incremental prognostic value of myocardial SPET with dual-isotope rest (201)Tl/stress (99m)Tc-tetrofosmin

    NARCIS (Netherlands)

    Groutars, Reginald G. E. J.; Verzijlbergen, J. Fred; Zwinderman, Aeilco H.; Tiel-van Buul, Monique M. C.; Ascoop, Carl A. P. L.; van Hemel, Norbert M.; van der Wall, Ernst E.

    2002-01-01

    The incremental prognostic value of dual-isotope myocardial perfusion scintigraphy using technetium-99m tetrofosmin for the stress images was evaluated in 597 consecutive patients with known or suspected coronary artery disease. We used semi-quantitative visual analysis with a five-point scoring

  14. Gated single photon emission computer tomography for the detection of silent myocardial ischemia

    International Nuclear Information System (INIS)

    Pena Q, Yamile; Coca P, Marco Antonio; Batista C, Juan Felipe; Fernandez-Britto, Jose; Quesada P, Rodobaldo; Pena C; Andria

    2009-01-01

    Background: Asymptomatic patients with severe coronary atherosclerosis may have a normal resting electrocardiogram and stress test. Aim: To assess the yield of Gated Single Photon Emission Computer Tomography (SPECT) for the screening of silent myocardial ischemia in type 2 diabetic patients. Material and methods: Electrocardiogram, stress test and gated-SPECT were performed on 102 type 2 diabetic patients aged 60 ± 8 years without cardiovascular symptoms. All subjects were also subjected to a coronary angiography, whose results were used as gold standard. Results: Gated-SPECT showed myocardial ischemia on 26.5% of studied patients. The sensibility, specificity, accuracy, positive predictive value and negative predictive value were 92.3%, 96%, 95%, 88.8%, 97.3%, respectively. In four and six patients ischemia was detected on resting electrocardiogram and stress test, respectively. Eighty percent of patients with doubtful resting electrocardiogram results and 70% with a doubtful stress test had a silent myocardial ischemia detected by gated-SPECT. There was a good agreement between the results of gated-SPECT and coronary angiography (k =0.873). Conclusions: Gated-SPECT was an useful tool for the screening of silent myocardial ischemia

  15. Early myocardial damage assessment in dystrophinopathies using 99Tcm-MIBI gated myocardial perfusion imaging

    Directory of Open Access Journals (Sweden)

    Zhang L

    2015-12-01

    Full Text Available Li Zhang,1,* Zhe Liu,2,* Ke-You Hu,3 Qing-Bao Tian,3 Ling-Ge Wei,4 Zhe Zhao,5 Hong-Rui Shen,5 Jing Hu5 1Department of Cardiovascular Disorders, 2Department of Geriatrics, The Third Hospital of Hebei Medical University, 3The Public Health Department, Hebei Medical University, 4Department of Nuclear Medicine, 5Department of Neuromuscular Disorders, The Third Hospital of Hebei Medical University, Shijiazhuang, People’s Republic of China *Li Zhang and Zhe Liu are first coauthors of this paper Background: Early detection of muscular dystrophy (MD-associated cardiomyopathy is important because early medical treatment may slow cardiac remodeling and attenuate symptoms of cardiac dysfunction; however, no sensitive and standard diagnostic method for MD at an earlier stage has been well-recognized. Thus, the aim of this study was to test the early diagnostic value of technetium 99m-methoxyisobutylisonitrile (99Tcm-MIBI gated myocardial perfusion imaging (G-MPI for MD.Methods and results: Ninety-one patients underwent 99Tcm-MIBI G-MPI examinations when they were diagnosed with Duchenne muscular dystrophy (DMD (n=77 or Becker muscular dystrophy (BMD; n=14. 99Tcm-MIBI G-MPI examinations were repeated in 43 DMD patients who received steroid treatments for 2 years as a follow-up examination. Myocardial defects were observed in nearly every segment of the left ventricular wall in both DMD and BMD patients compared with controls, especially in the inferior walls and the apices by using 99Tcm-MIBI G-MPI. Cardiac wall movement impairment significantly correlated with age in the DMD and BMD groups (rs=0.534 [P<0.05] and rs=0.784 [P<0.05], respectively. Intermittent intravenous doses of glucocorticoids and continuation with oral steroid treatments significantly improved myocardial function in DMD patients (P<0.05, but not in BMD patients.Conclusion: 99Tcm-MIBI G-MPI is a sensitive and safe approach for early evaluation of cardiomyopathy in patients with DMD or BMD

  16. Relationship between quantitative evaluation of myocardial infarction size using gated CT and cardiac function

    International Nuclear Information System (INIS)

    Kuroki, Kazunori

    1990-01-01

    The purpose of this study is to evaluate the relationship between quantitative evaluation of myocardial infarction size on Gated CT and cardiac function. A total 56 cases of myocardial infarction were studied. Calculation of infarct size ratio to whole left ventricle myocardium was performed. Correlation was evaluated between infarct size and various methods of grading cardiac functions (effort tolerance potentiality, NYHA classification of cardiac function, cardiac failure and complications). Good correlation with NYHA classification of cardiac function and cardiac failure was obtained. However, there was no significant correlation with effort tolerance potentiality and complications. In conclusion, it is warranted to say that quantitative evaluation of myocardial infarction size on Gated CT is very useful for management decision of patients with myocardial infarction. (author)

  17. Assessment of left ventricular function by 201Tl FCG-gated myocardial SPECT

    International Nuclear Information System (INIS)

    Toba, Masahiro; Ishida, Yoshio; Fukuchi, Kazuki; Fukushima, Kazuhito; Katafuchi, Tetsurou; Hayashida, Kohei; Oka, Hisashi; Takamiya, Makoto

    1999-01-01

    We applied the QGS program for LV function analysis (described by Germano, 1995) to a 201 Tl SPECT study at rest, and estimated its accuracy. We performed 201 Tl ECG-gated myocardial SPECT in 25 patients with ischemic heart disease under an acquisition time used in the routine 99m Tc ECG-gated SPECT study. The quality of the gated images was visually assessed with a 4-point grading system. LVEDV, LVESV, LVEF determined by the QGS program were compared with those by Simpson's method on biplane LVG in 25 patients. Regional wall motion scores in 7 myocardial segments were assessed on the three-dimensional display created by the QGS program and the cine display of biplane LVG with a 5-point grading system. Wall motion scores obtained by the QGS program were compared with those by LVG. Although 72.0% of 201 Tl ECG-gated SPECT images were fair or poor in image quality, there were good correlations between the values obtained by the QGS program and LVG (LVEDV: r=0.82, LVESV: r=0.88, LVEF: r=0.89). In addition, wall motion scores by the QGS program were correspondent to those by LVG in 77.1% of all 175 myocardial segments. We conclude that the QGS program provides high accuracy in evaluating left ventricular function even from 201 Tl ECG-gated myocardial SPECT data. (author)

  18. Incremental prognostic value of myocardial SPET with dual-isotope rest {sup 201}Tl/stress {sup 99m}Tc-tetrofosmin

    Energy Technology Data Exchange (ETDEWEB)

    Groutars, R.G.E.J.; Ascoop, C.A.P.L.; Hemel, N.M. van [Dept. of Cardiology, St. Antonius Hospital, Nieuwegein (Netherlands); Verzijlbergen, F.J.; Tiel-van Buul, M.M.C. [Dept. of Nuclear Medicine, St. Antonius Hospital, Nieuwegein (Netherlands); Zwinderman, A.H. [Dept. of Medical Statistics, University Hospital, Leiden (Netherlands); Wall, E.E. van der [Dept. of Cardiology, University Hospital, Leiden (Netherlands)

    2002-01-01

    The incremental prognostic value of dual-isotope myocardial perfusion scintigraphy using technetium-99m tetrofosmin for the stress images was evaluated in 597 consecutive patients with known or suspected coronary artery disease. We used semi-quantitative visual analysis with a five-point scoring system and calculated the summed stress score, the summed rest score and the summed difference score. During the 2-year follow-up period, 46 ''hard'' cardiac events occurred: 16 cardiac deaths and 30 non-fatal myocardial infarctions. Kaplan-Meier analysis demonstrated a favourable prognosis for patients with normal scans as compared with patients with mildly to moderately or severely abnormal scans (P<0.001). Multivariate analysis demonstrated incremental prognostic information for nuclear variables. A very low rate of hard cardiac events was observed in patients with a low summed stress score. Thus, nuclear variables provide incremental prognostic information and could be used to guide the management process with respect to whether or not to proceed with further invasive procedures. (orig.)

  19. Comparison of myocardial function between post-menopausal and pre-menopausal women: evaluation by gated myocardial SPECT

    International Nuclear Information System (INIS)

    Hwang, K. H.; Choa, Won Sick; Yoon, Min Ki

    2005-01-01

    In addition to inhibiting coronary atherosclerosis, estrogen is expected to have protective effects on cardiac myocytes. We investigated the difference in myocardial functional parameters evaluated by gated myocardial SPECT after adenosine-stress between post-menopausal and pre-menopausal healthy women. This study included 22 healthy post-menopausal women (mean age: 53.0 yr) and 20 pre-menopausal women (mean age: 43.0 yr) who performed Tc-99m tetrofosmin gated myocardial SPECT after adenosine-stress. Measured hemodynamic parameters, EDV, ESV, stroke volume, EF, cardiac output and cardiac index were compared between the two groups. For comparison, similar-aged two male groups with matched numbers were also studied. There was no significant difference in hemodynamic parameters. EDV, ESV, stroke volume, EF, or cardiac output between the post-menopausal and pre-menopausal women. However, post-menopausal women have a smaller cardiac index (mean: 1.95 L/min/m2 vs 2.20 L/min/m2; p=0.045) and adenosine-induced HR increase (mean : 80.5/min vs 89.7/min ; p=0.03), compared to the pre-menopausal women. On the contrary, the two male groups of the same age range and numbers with the women groups showed no significant difference in any myocardial parameters. These results suggest that menopause may be correlated with reduced increase in cardiac index and HR increase after adenosine-stress

  20. Comparison of myocardial function between post-menopausal and pre-menopausal women: evaluation by gated myocardial SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, K. H.; Choa, Won Sick; Yoon, Min Ki [Gachon Medical School, Gil Hospital, Incheon (Korea, Republic of)

    2005-07-01

    In addition to inhibiting coronary atherosclerosis, estrogen is expected to have protective effects on cardiac myocytes. We investigated the difference in myocardial functional parameters evaluated by gated myocardial SPECT after adenosine-stress between post-menopausal and pre-menopausal healthy women. This study included 22 healthy post-menopausal women (mean age: 53.0 yr) and 20 pre-menopausal women (mean age: 43.0 yr) who performed Tc-99m tetrofosmin gated myocardial SPECT after adenosine-stress. Measured hemodynamic parameters, EDV, ESV, stroke volume, EF, cardiac output and cardiac index were compared between the two groups. For comparison, similar-aged two male groups with matched numbers were also studied. There was no significant difference in hemodynamic parameters. EDV, ESV, stroke volume, EF, or cardiac output between the post-menopausal and pre-menopausal women. However, post-menopausal women have a smaller cardiac index (mean: 1.95 L/min/m2 vs 2.20 L/min/m2; p=0.045) and adenosine-induced HR increase (mean : 80.5/min vs 89.7/min ; p=0.03), compared to the pre-menopausal women. On the contrary, the two male groups of the same age range and numbers with the women groups showed no significant difference in any myocardial parameters. These results suggest that menopause may be correlated with reduced increase in cardiac index and HR increase after adenosine-stress.

  1. Is there an association between hibernating myocardium and left ventricular mechanical dyssynchrony in patients with myocardial infarction?

    Science.gov (United States)

    Zhang, Feifei; Yang, Wei; Wang, Yuetao; Tang, Haipeng; Wang, Jianfeng; Shao, Xiaoliang; Wang, Ziyi; Zhang, Xiaoying; Yang, Ling; Wang, Xiaosong; Zhou, Weihua

    2018-03-20

    Left ventricular mechanical dyssynchrony (LVMD) is an important factor in the prognosis of patients with myocardial infarction (MI). The aim of this study is to identify the influencing factors of LVMD in MI patients by radionuclide myocardial imaging. This study consisted of 91 patients who had a history of definite prior MI and underwent both technetium-99m methoxyisobutylisonitrile ( 99m Tc-MIBI) gated single photon emission tomography (SPET) myocardial perfusion imaging (MPI) and 18 F-FDG positron emission tomography (PET) myocardial metabolic imaging. Left ventricular (LV) functional and LVMD parameters were measured from gated SPET MPI, while myocardial viability was assessed by the integral quantitative analysis of SPET MPI and 18 F-FDG PET. Left ventricular MD was defined as >mean+2SD of phase bandwidth (PBW) in the control group. Left ventricular MD was present in 37/91 (40.7%) MI patients. Hibernating myocardium (SPET/PET mismatch) and scar in patients with LVMD were significantly higher than those without LVMD (15.24±11.26% vs 4.89±5.41%, P6.5% hibernating myocardium as a threshold can be used to better discriminate LVMD. In addition, the improvement of PBW (ΔPBW) after CABG at a median follow-up time of 6 months was related with the amount of hibernating myocardium. Myocardial infarction patients with LVMD show significantly more segments of larger amounts of hibernating myocardium and scars as compared to those without LVMD. Hibernating myocardium is independently associated with LVMD in MI patients.

  2. Quantification of left ventricular function by gated myocardial perfusion SPECT using multidimTM

    International Nuclear Information System (INIS)

    Huang Jin; Song Wenzhong; Chen Mingxi

    2004-01-01

    Objective: To evaluate the accuracy of left ventricular function by gated SPECT using the software Multidim TM . Methods: Rest gated SPECT was performed on 42 cases involved 26 normal subjects and 16 patients with myocardial infarct (MI). All cases underwent rest equilibrium radionuclide angiocardiography (ERNA) within 1 w. Results: (1)End diastolic volume (EDV), end systolic volume (ESV) and left ventricular ejection fraction(LVEF)were calculated using the software MultidimtMand ERNA. The correlation coefficient between the two Methods was 0.90,0.89,0.92 respectively(P TM , but the EDV and ESV value measured by this software maybe high with small heart. (authors)

  3. The values of myocardial tomography imaging and gated cardiac blood pool imaging in detecting left ventricular aneurysm

    International Nuclear Information System (INIS)

    Zhu Mei; Pan Zhongyun; Li Jinhui

    1992-01-01

    The sensitivity and specificity of myocardial tomography imaging and gated cardiac blood-pool imaging in detecting LVA were studied in 36 normal subjects and 68 patients with myocardial infarction. The sensitivities of exercise and rest myocardial imaging in detecting LVA were 85% and 77.3% respectively. The specificity of both is 95.5%. The sensitivity of cinema display, phase analysis and left ventricular phase shift in evaluating LVA were 86.7%, 86.7%, 100% respectively. Their specificity were all 100%. It is concluded that blood pool imaging is of choice for the diagnosis of LVA, and that myocardial imaging could also demonstrate LVA during diagnosing myocardial infarction

  4. Assessment of myocardial perfusion and function in victims of scorpion envenomation using gated-SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Figueiredo, Alexandre Baldini de; Cupo, Palmira; Pintya, Antonio O.; Caligaris, Fabio; Marin-Neto, Jose A; Hering, Sylvia E.; Simoes, Marcus Vinicius, E-mail: simoesmv@yahoo.co [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Hospital das Clinicas

    2010-04-15

    Background: cardiogenic shock and acute pulmonary edema are the major causes of death of patients with scorpion envenomation, whose pathophysiological mechanism remains controversial. Objective: to investigate the correlation between myocardial perfusion abnormalities and left ventricular contractile function in victims of scorpion envenomation. Methods: fifteen patients underwent ECG-gated myocardial perfusion scintigraphy (gated SPECT) within 72 hours of, and 15 days after scorpion envenomation. Images were analyzed by means of a semi-quantitative visual perfusion score (0 = normal, 4 = absent) and motion score (0 = normal, 4 akinesia), using the 17-segment model. Summed perfusion (SPS) and summed motion (SMS) scores were calculated for each patient. Ejection fraction (LVEF) was calculated by a commercially available software. Results: at baseline, 12 out of the 15 patients presented abnormal myocardial perfusion and contractility. Mean values of SPS, SMS and LVEF were 12.5 +- 7.3, 17.0 +- 12.8, and 44.6 +- 16.0%, respectively. A positive correlation between SPS and SMS (r = 0.68; p = 0.005) and negative correlation between SPS and LVEF (r -0.75; p = 0.0021) were found. The follow-up studies showed recovery of global contractility (LVEF of 68.9 +- 9.5, p = 0.0002), segmental contractility (SMS of 2.6 +- 3.1, p = 0.0009) and perfusion (SPS of 3.7 +- 3.3, p = 0.0003). Improvement of LVEF correlated positively with improvement of SPS (r = 0.72; p = 0.0035). Conclusions: myocardial perfusion abnormalities are common in scorpion envenomation and correlate topographically with the contractile dysfunction. Recovery of contractility correlates with reversibility of perfusion defects. These findings suggest the participation of myocardial perfusion abnormalities in the pathophysiology of this form of acute ventricular failure. (author)

  5. Analysis of Myocardial Function Using Gated Myocardial SPECT : Comparison of QGS, 4D-MSPECT Software and Echocardiography

    International Nuclear Information System (INIS)

    Lee, Seok Mo; Bae, Sang Kyun

    2008-01-01

    Gated myocardial perfusion SPECT provides not only myocardial perfusion status but also various functional parameters of left ventricle. We compared left ventricular ejection fraction, end-diastolic volume, LV mass by cardiac SPECT using Quantitative Gated SPECT (QGS), 4D-MSPECT software and standard 2D-echocardiography. One hundred fourteen patients (male 51, female 63; 29-85 years old, mean 61.3 ± 13.3 years old) with normal perfusion status on Tc-99m tetrofosmin gated myocardial perfusion SPECT were analyzed retrospectively. Ejection fraction (LVEF), End-diastolic volume (LVED), LV mass (LVM) were calculated using QGS, 4D-MSPECT, and LVEF, LVM using 2D-echocardiography. Statistical analysis including Bland-Altman plot was performed using MedCalc (MedCalc software, Mariakerke, Belgium). The correlation of LVEF between methods was good: 0.95/0.96 (stress/rest) between QGS and 4D-MSPECT, 0.79 between QGS and echocardiography, 0.79 between 4D-MSPECT and echocardiography (p<0.001). Using Bland-Altman plot, the 95% confidence interval of agreement between QGS and 4D-MSPECT ranged from -12.7% to 7.3% / from -12.2% to 6.5% (stress/rest). The agreement between QGS and echocardiography, 4D-MSPECT and echocardiography ranged from -17.4% to 24.0%, and -14.8% to 27.0% respectively. The correlation of LVM between methods was also good: 0.95 between QGS and 4D-MSPECT, 0.76 between QGS and echocardiography, 0.73 between 4D-MSPECT and echocardiography (p<0.001). The 95% confidence interval of agreement between QGS and 4D-MSPECT ranged from -33.8 g to 14.1 g (stress/rest). The 95% confidence interval of agreement between QGS and echocardiography, 4D-MSPECT and echocardiography ranged from -148.7 g to 21.8. g, and -142.8 g to 35.5 g, respectively. There was a good correlation for LVEF, LVED, LVM among methods (QGS, 4D-MSPECT, echocardiography), but the variance between methods was big. Therefore, the functional parameters by each method cannot be used interchangeably

  6. Reference Range of Functional Data of Gated Myocardial Perfusion SPECT by Quantitative Gated SPECT of Cedars-Sinai and 4D-MSPECT of Michigan University

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Do Young; Kim, Moo Hyun; Kim, Young Dae [College of Medicine, Univ. of Donga, Pusan (Korea, Republic of)

    2003-07-01

    Various programs have been developed for gating of myocardial perfusion SPECT. Among the those program, the most popular program is the Quantitative Gated SPECT (QGS)? developed by Cedars-Sinai hospital and most recently released program is 4D-MSPECT? developed by university of Michigan. It is important to know the reference range of the functional data of gated myocardial perfusion SPECT because it is necessary to determine abnormality of individual patient and echocardiographic data is different from those of gated SPECT. Tc-99m MIBI gated myocardial perfusion SPECT image was reconstructed by dual head gamma camera (Siemens, BCAM, esoft) as routine procedure and analyzed using QGS? and 4D-MSPECT? program. All patients (M: F=9: 18, Age 69{+-}9 yrs) showed normal myocardial perfusion. The patients with following characteristics were excluded: previous angina or MI history, ECG change with Q wave or ST-T change, diabetes melitius, hypercholesterolemia, typical chest pain, hypertension and cardiomyopathy. Pre-test likelihood of all patients was low. (1) In stress gated SPECT by QGS?, EDV was 73{+-}25 ml, ESV 25{+-}14 ml, EF 67{+-}11 % and area of first frame of gating 106.4{+-}21cm{sup 2}. In rest gated SPECT, EDV was 76{+-}26 ml, ESV 27{+-}15 ml, EF 66{+-}12 and area of first frame of gating 108{+-}20cm{sup 2}. (2) In stress gated SPECT by 4D-MSPECT?, EDV was 76{+-}28 ml, ESV 23{+-}16 ml, EF 72{+-}11 %, mass 115{+-}24 g and ungated volume 42{+-}15 ml. In rest gated SPECT, EDV was 75{+-}27 ml, ESV 23{+-}12 ml, EF 71{+-}9%, mass 113{+-}25g and ungate dvolume 42{+-}15 ml, (3) s-EDV, s-EF, r-ESV and r-EF were significantly different between QGS? and 4D-MSPECT? (each p=0.016, p<0.001. p=0.003 and p=0.001). We determined the normal reference range of functional parameters by QGS? and 4D-MSPECT? program to diagnose individually the abnormality of patients. And the reference ranges have to adopted to be patients by each specific gating program.

  7. Myocardial enhancement pattern in patients with acute myocardial infarction on two-phase contrast-enhanced Ecg-gated multidetector-row computed tomography

    International Nuclear Information System (INIS)

    Ko, S.M.; Seo, J.B.; Hong, M.K.; Do, K.H.; Lee, S.H.; Lee, J.S.; Song, J.W.; Park, S.J.; Park, S.W.; Lim, T.H.

    2006-01-01

    Aim: To evaluate the myocardial enhancement pattern of the left ventricle on two-phase contrast-enhanced electrocardiogram (ECG)-gated multidetector computed tomography (MDCT) images in patients with acute myocardial infarction (AMI). METHODS: Two-phase contrast-enhanced ECG-gated MDCT examinations were performed in 16 patients with AMI. The presence, location and pattern of myocardial enhancement were evaluated. MDCT findings were compared with the catheter angiographic results. RESULTS: Subendocardial (n=9) or transmural (n=6) area of early perfusion defects of the myocardium was detected in 15 of 16 patients (94%) on early-phase CT images. Variable delayed myocardial enhancement patterns on late-phase CT images were observed in 12 patients (75%): (1) subendocardial residual perfusion defect and subepicardial late enhancement (n=6); (2) transmural late enhancement (n=1); (3) isolated subendocardial late enhancement (n=1); and (4) isolated subendocardial residual perfusion defect (n=2). On catheter angiography, 14 of 15 corresponding coronary arteries showed significant stenosis. CONCLUSION: Variable abnormal myocardial enhancement pattern was seen on two-phase, contrast-enhanced ECG-gated MDCT in patients with AMI. Assessment of myocardial attenuation on CT angiography gives additional information of the location and extent of infarction

  8. A study of glycogen storage disease with 99Tcm-MIBI gated myocardial perfusion imaging.

    Science.gov (United States)

    Wei, L G; Gao, J Q; Liu, X M; Huang, J M; Li, X Z

    2013-12-01

    Gated myocardial perfusion imaging (G-MPI) is regularly performed using single-photon emission computed tomography. The objective of this study was to evaluate the clinical value of 99Tcm-methoxyisobutylisonitrile (MIBI) myocardial imaging in glycogen storage disease (GSD). 99Tcm-MIBI G-MPI was performed in nine patients with clinically proven GSD. QGS quantitative software was used for processing and interpretation. Left ventricular ejection fraction (LVEF), end-diastolic volume (EDV) and end-systolic volume (ESV) were automatically generated. The myocardium was divided into seven segments, 20 sub-segments and a five-point scoring system was used. Seven out of nine cases were abnormal and the positive rate of G-MPI was 77.8 %. Sixty-two sub-segments of injured myocardium were detected in 140 sub-segments of seven abnormal patients. One injured segment was observed in one patient (14.3 %), two segments were detected in two patients (28.6 %) and three or more abnormal segments were observed in four patients (57.1 %). 99Tcm-MIBI G-MPI can detect myocardial damage in GSD as a non-invasive method. It plays an important role in the clinic.

  9. Imaging Three-Dimensional Myocardial Mechanics Using Navigator-gated Volumetric Spiral Cine DENSE MRI

    Science.gov (United States)

    Zhong, Xiaodong; Spottiswoode, Bruce S.; Meyer, Craig H.; Kramer, Christopher M.; Epstein, Frederick H.

    2010-01-01

    A navigator-gated 3D spiral cine displacement encoding with stimulated echoes (DENSE) pulse sequence for imaging 3D myocardial mechanics was developed. In addition, previously-described 2D post-processing algorithms including phase unwrapping, tissue tracking, and strain tensor calculation for the left ventricle (LV) were extended to 3D. These 3D methods were evaluated in 5 healthy volunteers, using 2D cine DENSE and historical 3D myocardial tagging as reference standards. With an average scan time of 20.5 ± 5.7 minutes, 3D data sets with a matrix size of 128 × 128 × 22, voxel size of 2.8 × 2.8 × 5.0 mm3, and temporal resolution of 32 ms were obtained with displacement encoding in three orthogonal directions. Mean values for end-systolic mid-ventricular mid-wall radial, circumferential, and longitudinal strain were 0.33 ± 0.10, −0.17 ± 0.02, and −0.16 ± 0.02, respectively. Transmural strain gradients were detected in the radial and circumferential directions, reflecting high spatial resolution. Good agreement by linear correlation and Bland-Altman analysis was achieved when comparing normal strains measured by 2D and 3D cine DENSE. Also, the 3D strains, twist, and torsion results obtained by 3D cine DENSE were in good agreement with historical values measured by 3D myocardial tagging. PMID:20574967

  10. Measurement of left ventricular chamber and myocardial volume in hypertrophic cardiomyopathy patients by ECG-gated myocardial perfusion SPECT. Application of a newly developed edge-detection algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, Yoshihiro; Katafuchi, Tetsuro; Hirase, Yoshinori; Sagoh, Masayoshi; Oka, Hisashi [National Cardiovascular Center, Suita, Osaka (Japan); Mori, Hideaki [Siemens-Asahi Medical Technologies, Ltd., Tokyo (Japan); Murase, Kenya [Osaka Univ., Suita (Japan). Medical School

    2002-12-01

    Quantitative gated SPECT (QGS) software has been reported to demonstrate inaccurate edge detection in the left ventricular chamber in hypertrophic cardiomyopathy patients. In this study we developed a method to calculate left ventricular volume (LVV) and left myocardial volume (LMV) from gated SPECT data using a newly developed edge-detection algorithm, and we compared it with the QGS method of calculating LVV and LMV in a phantom study. Our method gave more accurate measurements LVV and LMV whereas the QGS method underestimated LMV. Compared with QGS LVV and LMV, our method yielded better results in the phantom study. (author)

  11. Left ventricular systolic wall motion after exercise stress and myocardial perfusion in patients with ischemic heart disease. Investigation by ECG gated myocardial tomography

    Energy Technology Data Exchange (ETDEWEB)

    Narita, Michihiro; Kurihara, Tadashi; Sindoh, Takashi; Sawada, Yoshihiro; Honda, Minoru [Sumitomo Hospital, Osaka (Japan)

    2001-01-01

    To investigate regional left ventricular (LV) wall motion (WM) after recovery from myocardial ischemia, we performed ECG-gated myocardial perfusion tomography with {sup 99m}Tc-MIBI (G-SPECT) in patients with ischemic heart disease (IHD). In addition, we compared the left ventricular (LV) systolic function obtained by G-SPECT at rest with that obtained by contrast left ventriculography (LVG). We performed G-SPECT at 30 minutes after exercise stress (Ex-30) and 3 hours after exercise (rest). LVWM and LV ejection fractions (EF) were analyzed by the QGS (quantitative gated SPECT) program. The LV was divided into 9 segments and regional WM (RWM) was analyzed quantitatively. In addition, myocardial perfusion was assessed quantitatively. In 64 patients with several different types of heart disease, EF obtained by G-SPECT correlated well with LVG-EF (r=0.907, p<0.001), and RWM of G-SPECT coincided well with that of LVG ({kappa} value 0.67, p<0.01). Eighty patients with suspected IHD were divided according to Ex-Rest myocardial perfusion. In 83% of patients with Ex-induced perfusion abnormalities disappeared completely at rest, and in 58% of patients with Ex-induced abnormalities disappeared incompletely, RWM abnormalities which were observed at Ex-30 improved at rest and as did EF. In 79% of patients with a fixed defect (FD), RWM abnormalities and EF at Ex-30 did not differ with those at rest, but in 12% of the patients, the RWM abnormality of Ex-30 improved at rest. In most myocardial segments that had recovered from transient ischemia, RWM abnormalities persisted at least 30 minutes after Ex (stunning). In a small portion of the myocardial segments regarded as having myocardial necrosis because of a fixed perfusion abnormality, RWM abnormalities at Ex-30 improved at rest. These segments were supposed to contain viable myocardium. In conclusion, G-SPECT is a powerful method for clarifying the relation between the regional systolic function and myocardial perfusion

  12. Reproducibility of the assessment of myocardial function using gated Tc-99m-MIBI SPECT and quantitative software

    International Nuclear Information System (INIS)

    Lee, Dong Soo; Cheon, Gi Jeong; Ahn, Ji Young; Jeong, Joon Ki; Lee, Myung Chul

    1998-01-01

    We investigated reproducibility of the quantification of left ventricular volume and ejection fraction, and grading of myocardial wall motion and systolic thickening when we used gated myocardial SPECT and Cedars quantification software. We performed gated myocardial SPECT in 33 consecutive patients twice in the same position after Tc-99m-MIBI SPECT. We used 16 frames per cycle for the gating of sequential Tc-99m-MIBI SPECT. After reconstruction, we used Cedars quantitative gated SPECT and calculated ventricular volume and ejection fraction (EF). Wall motion was graded using 5 point score. Wall thickening was graded using 4 point score. Coefficient of variation for re-examination of volume and fraction were calculated. Kappa values (k-value) for assessing reproducibility of wall motion or wall thickening were calculated. Enddiastolic volumes (EDV) ranged from 58 ml to 248 ml (122 ml +/-42 ml), endsystolic volumes (ESV) from 20 ml to 174 ml (65 ml+/-39 ml), and EF from 20% to 68% (51%+/-14%). Geometric mean of standard deviations of 33 patients was 5.0 ml for EDV, 3.9 ml for ESV and 1.9% for EF. Their average differences were not different from zero (p>0.05). k-value for wall motion using 2 consecutive images was 0.76 (confidence interval: 0.71-0.81). k-value was 0.87 (confidence interval: 0.83-0.90) for assessment of wall thickening. We concluded that quantification of functional indices, assessment of wall motion and wall thickening using gated Tc-99m MIBI SPECT was reproducible and we could use this method for the evaluation of short-acting drug effect

  13. The application of phase analysis of gated myocardial perfusion imaging to assess left ventricular mechanical dyssynchrony in cardiovascular disease

    International Nuclear Information System (INIS)

    Wang Jianfeng; Wang Yuetao

    2013-01-01

    Left ventricular mechanical dyssynchrony is closely related to the severity of cardiovascular disease, it is essential to assess left ventricular mechanical dyssynchrony accurately for early prediction of adverse cardiac events and prognosis assessment of the cardiac resynchronization therapy. As a new technology to assess left ventricular mechanical dyssynchrony, the phase analysis of gated myocardial perfusion imaging (GMPI) can get both quantitative indicators of regional myocardial perfusion, evaluation of regional myocardial viability and scar tissue, as well as quantitative analysis of left ventricular function and left ventricular mechanical synchrony, it has broad application prospects in cardiovascular disease to assess left ventricular mechanical dyssynchrony and prognosis assessment. This review mainly described the applications of GMPI phase analysis in the cardiovascular disease. (authors)

  14. Diagnosis of silent myocardial ischemia in type 2 diabetic patients by electrocardiogram, ergometry and Gated-SPECT

    International Nuclear Information System (INIS)

    Penna Quian, Yamile; Fernandez-Britto Rodriguez, Jose; Bacallao Gallestey, Jorge; Batista Cuellar, Juan Felipe; Coca Perez, Marco Antonio; Toirac Garcia, Noresma; Penna Coego, Andria

    2008-01-01

    31 asymptomatic type 2 diabetic patients were studied by lab tests, electrocardiogram, ergometry, Gated-SPECT and coronariography to determine the relation between the atherosclerotic risk factors and the silent myocardial ischemia. Patients were classified into two groups: positive SPECT and negative SPECT. Association tests were made for each variable and ROC curves were constructed to identify risk markers. In 35.5% of the patients silent myocardial ischemia was detected with a good angiographic correlation. A significant association was evidenced between positive SPECT and the atherosclerotic risk factors, namely, low values of HDLc, family pathological history of ischemic heart disease and peripheral vascular disease. The logistic regression models showed that low values of HDLc together with family pathological history of ischemic heart disease may be strong predictors of silent myocardial ischemia in asymptomatic type 2 diabetic patients

  15. Reproducibility of an automatic quantitation of regional myocardial wall motion and systolic thickening on gated Tc-99m-MIBI myocardial SPECT

    International Nuclear Information System (INIS)

    Paeng, Jin Chul; Lee, Dong Soo; Cheon, Gi Jeong; Kim, Yu Kyeong; Chung, June Key; Lee, Myung Chul

    2000-01-01

    The aim of this study is to investigate the reproducibility of the quantitative assessment of segmental wall motion and systolic thickening provided by an automatic quantitation algorithm. Tc-99m-MIBI gated myocardial SPECT with dipyridamole stress was performed in 31 patients with known or suspected coronary artery disease (4 with single, 6 with two, 11 with triple vessel disease; ejection fraction 51±14%) twice consecutively in the same position. Myocardium was divided into 20 segments. Segmental wall motion and systolic thickening were calculated and expressed in mm and % increase respectively, using AutoQUANT TM software. The reproducibility of this quantitative measurement of wall motion and thickening was tested. Correlations between repeated measurements on consecutive gated SPECT were excellent for wall motion (r=0.95) and systolic thickening (r=0.88). On Bland-Altman analysis, two standard deviation was 2 mm for repeated measurement of segmental wall motion, and 20% for that of systolic thickening. The weighted kappa values of repeated measurements were 0.807 for wall motion and 0.708 for systolic thickening. Sex, perfusion, or segmental location had no influence on reproducibility. Segmental wall motion and systolic thickening quantified using AutoQUANT TM software on gated myocardial SPECT offers good reproducibility and is significantly different when the change is more than 2 mm for wall motion and more than 20% for systolic thickening

  16. Gated-SPECT myocardial scintigraphy in left bundle branch block: A study in patients with and without coronary artery disease

    International Nuclear Information System (INIS)

    Falcao, A.M.; Moffa, P.J.; Chalela, W.A.; Soares, J.; Oliveira, C.G.; Kreling, J.C.; Ferreira, B.A.; Uchida, A.H.; Meneghetti, J.C.

    2002-01-01

    Introduction: Myocardial perfusion scintigraphy (MPS) is a non-invasive method helpful for evaluating coronary heart disease. In left bundle branch block (LBBB), the myocardial scintigraphy frequently reveals septal abnormalities in the absence of coronary artery disease (CAD) and gives rise to 'false-positive' results in patients (pts) with suspected CAD. The purpose of this study was to assess the diagnostic role of ECG-gated SPECT in pts with complete LBBB, with and without known CAD. Methods. This study included 46 pts, 29 women (63%), with mean age 63.8 ± 11.6yr, divided into two groups: Group 1 (n=21 pts) with LBBB and CAD angiographically confirmed and Group 2 (n=25 pts) with LBBB and normal coronangiography. All pts underwent MPS at rest and two stress tests - dipyridamole (DIP) and treadmill exercise test (ET) with Bruce protocol. Myocardial perfusion, wall motility and wall thickening were analyzed qualitatively by consensus of two observers in anterior, septal, inferior, lateral and apical myocardial segments. Scores were attributed to: perfusion as normal, reversible or fixed defects; motility as normal, hypokinesia, akinesia or dyskinesia and thickening if present or absent. The left ventricle ejection fraction (LVEF) was automatically calculated from the ECG-gated SPECT. Results: The comparative analysis between groups 1 and 2 for both stresses (DIP and ET) for the parameters analyzed in the myocardial segments are presented: LVEF at rest, ET and DIP show statistically significant differences between groups 1 and 2 (p<0.0001). Conclusion: In the anterior and septal segments, only septal thickening was capable of differentiating between LBBB with and without CAD, independent of the kind of stress. In the other segments there was no influence of disturbance conduction for the perfusion analysis

  17. Performance of Thallium-201 Electrocardiography-gated Myocardial Perfusion Single Photon Emission Computed Tomography to Assess Left Ventricular Function

    Directory of Open Access Journals (Sweden)

    Guang-Uei Hung

    2005-05-01

    Full Text Available This study evaluated the performance of gated single photon emission computed tomography (SPECT with thallium-201 (201Tl in assessing left ventricular ejection fraction (LVEF, end-diastolic volume (EDV, and end-systolic volume (ESV in Taiwanese by determining repeatability and correlation with two-dimensional (2D echocardiography. A total of 18 patients underwent two sequential gated SPECT acquisitions within 30 minutes in the resting state to assess repeatability. Another 28 patients who underwent gated SPECT and 2D echocardiography within 7 days were included for comparison. The two sequential measurements were well correlated with respect to LVEF, EDV, and ESV (r = 0.97, 0.95, and 0.97, respectively, all p < 0.0001. Bland-Altman analysis revealed that two standard deviations of the absolute difference between the two sequential measurements for LVEF, EDV, and ESV were 6.4%, 16.8 mL, and 8.6 mL, respectively. For LVEF, EDV, and ESV, correlations between redistribution 201Tl-gated SPECT and echocardiography were also excellent (all r = 0.83, p < 0.0001. LVEF was similar with 201Tl-gated SPECT and echocardiography, but EDV and ESV were significantly higher with echocardiography (p < 0.05. Our study revealed that 201Tl-gated SPECT has high repeatability and excellent correlation with echocardiography for the assessment of LVEF and volumes in Taiwanese. These results support the clinical application of gated SPECT in routine 201Tl myocardial perfusion imaging in Taiwanese.

  18. The value of gated myocardial perfusion imaging for the evaluation of early treatment effectiveness of ischemic heart disease using Ad-HGF myocardial injection

    International Nuclear Information System (INIS)

    Feng Jianlin; Cheng Xu; Li Jianhua; Xu Zhaoqiang; Li Dianfu; Yuan Biao; Zhang Yourong; Cao Kejiang; Huang Jun

    2008-01-01

    Objective: Hepatocyte growth factor (HGF) has multipotent actions mediated by c- Mesenchymal epithelial transition factor (Met) receptor. Preclinical studies in animal models of myocardial ischemia demonstrated that treatment with HGF could benefit myocardial perfusion, cardiac remodeling, angiogenesis and myocardial function. This study used gated 99 Tc m -methoxyisobutylisonitrile (MIBI) myocardial perfusion imaging (G-MPI) to assess the early treatment effectiveness of adenovirus HGF (Ad-HGF) directly administered in ischemic heart disease (IHD) patients. Methods: Eighteen patients with IHD were divided into 3 groups receiving low dose [5 x 10 8 plaque forming unit (PFU)/site], medium (1.5 x 10 9 PFU/site) and high dose (5 x l0 9 PFU/site) of Ad-HGF. And the Ad-HGF was injected at 10 sites in each patient. Rest G-MPI was performed before and after treatment for myocardial perfusion and left ventricular function measurement. Stata 7.0 was used to analyse the data. Results: (1) After Ad-HGF, myocardial perfusion was improved in 3/6, 5/6 and 6/6 patients in low, medium and high dosage groups. The dosage of AD-HGF was closely correlated with the improvement of myocardial perfusion (χ 2 =4.34, P<0.05). (2) Left ventricular ejection fraction (LVEF) was significantly increased [(50.1 ± 6.4)% vs (58.7 ± 5.6)%, t=6.1, P<0.01], end-diastolic volume [EDV, (137.7 ± 33.2) ml vs (123.7 ± 32.7) ml] and end-systolic volume [ESV, (70.2 ± 22.4) ml vs (51.9 ± 14.9) ml] were significantly reduced. (3) The LVEFs were increased in all groups, and the LVEF improvement in the high dosage group [(8.6 ± 5.9)%] was significantly greater than the other two groups [(4.3 ± l.2)%, (6.8 ± 5.7)%]. The difference of post-treatment improvement on LVEF between the low and medium dosage groups was not significant. The dosage of Ad-HGF was closely correlated with the improvement of LVEF (r=0.67, P< 0.01). Conclusion: G-MPI is a reliable method for evaluating the early effectiveness of

  19. Normal value of functional parameters in gated myocardial perfusion SPECT in patients with low risk of coronary artery disease: emory cardiac tool box program

    Energy Technology Data Exchange (ETDEWEB)

    Kang, D. Y.; Kim, M. H.; Kim, Y. D.; Kim, D. K. [Donga University College of Medicine, Busan (Korea, Republic of)

    2002-07-01

    Absolute value of the functional data of gated myocardial perfusion SPECT is necessary to determine that individual patient is normal or not. Tc-99m MIBI gated myocardial perfusion SPECT was performed using emory cardiac tool box program. All patients (M:F=15:36, age 64{+-}10 yrs) showed normal myocardial perfusion. The patients with following characteristics were excluded; previous angina or MI, ECG change with Q wave or ST-T change, diabetes mellitus, hypercholesterolemia, typical chest pain and hypertension. In all patients, myocardial mass is 117{+-}23 g in stress gated SPECT, 106{+-}22 g in stress ungated SPECT and 102{+-}21 g in rest ungated SPECT. EDV is 90{+-}28 ml, ESV 26{+-}20 ml, SV 66{+-}21 ml, EF 73{+-}10 % and TID 1.06{+-}0.14. Myocardial mass in rest ungated SPECT is significantly different between men and women (p=0.025). Myocardial mass is significantly different between stress gated SPECT and stress ungated SPECT (p=0.000), and between stress ungated SPECT and rest ungated SPECT (p=0.003). We provide normal value of functional parameters to determine the abnormality of individual patients in patients with low risk of coronary artery disease.

  20. Effects of aortic tortuosity on left ventricular diastolic parameters derived from gated myocardial perfusion single photon emission computed tomography in patients with normal myocardial perfusion.

    Science.gov (United States)

    Kurisu, Satoshi; Nitta, Kazuhiro; Sumimoto, Yoji; Ikenaga, Hiroki; Ishibashi, Ken; Fukuda, Yukihiro; Kihara, Yasuki

    2017-12-05

    Aortic tortuosity is often found on chest radiograph, especially in aged patients. We tested the hypothesis that aortic tortuosity was associated with LV diastolic parameters derived from gated SPECT in patients with normal myocardial perfusion. One-hundred and twenty-two patients with preserved LV ejection fraction and normal myocardial perfusion were enrolled. Descending aortic deviation was defined as the horizontal distance from the left line of the aortic knob to the most prominent left line of the descending aorta. This parameter was measured for the quantitative assessment of aortic tortuosity. Peak filling rate (PFR) and one-third mean filling rate (1/3 MFR) were obtained from redistribution images as LV diastolic parameters. Descending aortic deviation ranged from 0 to 22 mm with a mean distance of 4.5 ± 6.3 mm. Descending aortic deviation was significantly correlated with age (r = 0.38, p < 0.001) and estimated glomerular filtration rate (eGFR) (r = - 0.21, p = 0.02). Multivariate linear regression analysis revealed that eGFR (β = 0.23, p = 0.02) and descending aortic deviation (β = - 0.23, p = 0.01) were significantly associated with PFR, and that only descending aortic deviation (β = - 0.21, p = 0.03) was significantly associated with 1/3 MFR. Our data suggest that aortic tortuosity is associated with LV diastolic parameters derived from gated SPECT in patients with normal myocardial perfusion.

  1. Myocardial infarction in rats: High-resolution single-photon emission tomographic imaging with a pinhole collimator

    International Nuclear Information System (INIS)

    Yukihiro, Masashi; Inoue, Tomio; Iwasaki, Tsutomu; Tomiyoshi, Katsumi; Erlandsson, K.; Endo, Keigo

    1996-01-01

    The purpose of this study was to evaluate the accuracy of myocardial imaging by means of high-resolution single-photon emission tomography (SPET) with a pinhole collimator in rats with experimental infarction. Myocardial infarctions were induced in male Wistar rats by ligation of the left coronary artery for 30 min, followed by reperfusion. Two days after the reperfusion, pinhole SPET was performed after the intravenous administration of 111 MBq of thallium-201 chloride, using a rotating gamma camera equipped with a pinhole insert (2.0-mm aperature) in a low-energy pinhole collimator. SPET projection data were collected at 6 increments over 360 using a 4-cm radius of rotation to reconstruct the short- and long-axis images. Projection data were acquired in 15 or 30 s, the SPET imaging being accomplished within 40 min after the injection of 201 Tl. After SPET, the rats were sacrificed to remove the hearts for autoradiography (ARG) and nitroblue tetrazolium (NBT) staining as a visual correlative study. Quantitative correlative studies between pinhole SPET and ARG were performed with linear regression analysis for infarct size and distribution properties (relative counts on SPET images and relative density on autoradiographs) on the short-axis sections. All infarcts (4 mm in minimum diameter) in seven rats were detected by pinhole SPET. The SPET images in rats with or without myocardial infarction were consistent within the findings of ARG and NBT staining. There were significant correlations between pinhole SPET and ARG with respect to the infarct size (r=0.933, P<0.001; n=15) and the relative radiotracer distribution (r=0.931, P<0.001; n=68). This study therefore confirmed the accuracy of myocardial pinhole SPET imaging in rats with myocardial infarction. This method may partially substitute for ARG and prove useful for assessing new myocardial imaging agents in vivo in small laboratory animals. (orig.)

  2. Feasibility of one-eighth time gated myocardial perfusion SPECT functional imaging using IQ-SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Caobelli, Federico; Thackeray, James T.; Bengel, Frank M. [Medizinische Hochschule Hannover, Klinik fuer Nuklearmedizin, Hannover (Germany); Soffientini, Alberto; Pizzocaro, Claudio; Guerra, Ugo Paolo [Fondazione Poliambulanza, Department of Nuclear Medicine, Brescia (Italy)

    2015-11-15

    IQ-SPECT, an add-on to general purpose cameras based on multifocal collimation, can reduce myocardial perfusion imaging (MPI) acquisition times to one-fourth that of standard procedures (to 12 s/view). In a phantom study, a reduction of the acquisition time to one-eighth of the standard time (to 6 s/view) was demonstrated as feasible. It remains unclear whether such a reduction could be extended to clinical practice. Fifty patients with suspected or diagnosed CAD underwent a 2-day stress-rest {sup 99m}Tc-sestamibi MPI protocol. Two consecutive SPECT acquisitions (6 and 12 s/view) were performed. Electrocardiogram-gated images were reconstructed with and without attenuation correction (AC). Polar maps were generated and visually scored by two blinded observers for image quality and perfusion in 17 segments. Global and regional summed stress score (SSS), summed rest score (SRS) and summed difference score (SDS) were determined. Left ventricular volumes and ejection fraction were calculated based on automated contour detection. Image quality was scored higher with the 12 s/view acquisition, both with and without AC. Summed scores were statistically comparable between the 6 s/view and the 12 s/view acquisition, both globally and in individual coronary territories (e.g. in images with AC, SSS were 6.6 ± 8.3 and 6.2 ± 8.2 with 6 s and 12 s/view, respectively, p = 0.10; SRS were 3.9 ± 5.6 and 3.5 ± 5.3, respectively, p = 0.19; and SDS were 2.8 ± 5.7 and 2.6 ± 5.7, respectively, p = 0.59). Both acquisitions allowed MPI-based diagnosis of CAD in 25 of the 50 patients (with AC). Calculated end-diastolic volume (EDV) and end-systolic volume (ESV) were modestly higher with the 6 s/view acquisition than with the 12 s/view acquisition (EDV +4.8 ml at rest and +3.7 ml after stress, p = 0.003; ESV +4.1 ml at rest and +2.6 ml after stress, p = 0.01), whereas the ejection fraction did not differ (-1.2 % at rest, p = 0.20, and -0.9 % after stress, p = 0.27). Image quality and

  3. Assessment of myocardial perfusion abnormality and hibernating myocardium by gated blood pool and exercise-stress thallium tomographies after successful coronary angioplasty

    International Nuclear Information System (INIS)

    Hashimoto, Akiyoshi; Nakata, Tomoaki; Tsuchihashi, Kazufumi

    1993-01-01

    Cardiac function and myocardial perfusion were assessed by exercise-stress thallium SPECT and resting gated blood pool SPECT techniques before and after 47 successful coronary angioplasties. Thallium perfusion was analyzed visually and quantitatively in stress and resting studies. Left ventricular ejection fraction (LVEF) and peak filling rate (PFR) were calculated and regional wall motion was scored by amplitude and phase images in radionuclide planar and tomographic imagings. The thallium redistribution in delayed or resting SPECTs was more sensitive (87%) for detecting myocardial ischemia compared to symptoms (36%) and ECG changes (60%). An exercise capacity, LVEF, PFR, and the scores of perfusion and regional wall motion were improved significantly after coronary angioplasty. Stress thallium and gated blood pool SPECTs showed the improvements of myocardial perfusion in 159 (79%) of 201 segments and regional wall motion in 47 (51%) of 92 segments, respectively. These results suggest that the combined use of stress thallium SPECT, gated blood pool planar and SPECT techniques can contribute not only to the assessment of the efficacy of coronary angioplasty but also to detecting the mismatching of myocardial perfusion and contraction ('myocardial hibernation') in infarct-related myocardial lesions. (author)

  4. Assessment of the effect of revascularization early after CABG using ECG-gated perfusion single-photon emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kubo, Shigeto; Tadamura, Eiji; Kudoh, Takashi; Inubushi, Masayuki; Konishi, Junji [Dept. of Nuclear Medicine and Diagnostic Imaging, Kyoto University Graduate (Japan); Ikeda, Tadashi; Koshiji, Takaaki; Nishimura, Kazunobu; Komeda, Masashi [Dept. of Cardiovascular Surgery, Kyoto University (Japan); Tamaki, Nagara [Dept. of Nuclear Medicine, Hokkaido University, Sapporo (Japan)

    2001-02-01

    When an arterial graft is used, reversible perfusion defects on single-photon emission tomography (SPET) perfusion images are occasionally observed early after coronary artery bypass graft surgery (CABG), owing to the restricted flow capacity. The purpose of this study was to determine whether the functional information obtained with electrocardiography (ECG)-gated perfusion SPET could be helpful in evaluating the effect of revascularization early after CABG. Twenty-three patients (18 men and 5 women, mean age 65{+-}9 years) underwent stress/re-injection thallium-201 ECG-gated SPET before and 4 weeks after CABG (13 with exercise and 10 with dipyridamole). Patency of all grafts was confirmed by coronary angiography 1 month after CABG. Cardiac functional data including the left ventricular ejection fraction (LVEF) and the transient ischaemic dilatation (TID) ratio were analysed using a commercially available automated program. The conventional stress and re-injection tomograms were interpreted by means of a five-point scoring system in a nine-segment model. Stress-induced reversible {sup 201}Tl perfusion defects were present in 64% of the myocardial segments bypassed by patent arterial grafts, in contrast to 42% of the myocardial segments bypassed by patent venous grafts ({chi}{sup 2}=7.8, P=0.005). Of the 23 patients, 12 showed improvement in summed ischaemic scores (group 1), while 11 had no change or deterioration (group 2), although all grafts were patent on postoperative catheterization. The TID ratio improved in both group 1 and group 2 before and after CABG (1.14{+-}0.13 vs 0.99{+-}0.07, P=0.001 and 1.09{+-}0.07 vs 0.94{+-}0.05, P=0.002, respectively). However, LVEF did not significantly improve in group 1 or group 2 after CABG (42.5%{+-}9.9% vs 47.5%{+-}11.8%, and 52.1%{+-}7.5% vs 53.1%{+-}5.9%, respectively). Perfusion imaging or LVEF assessment is of limited value early after CABG. The TID ratio obtained with ECG-gated perfusion SPET may be a useful marker

  5. Establishment of normal limits for left ventricular ejection fraction and volume measurements from 99Tcm-sestamibi myocardial perfusion gated SPECT

    International Nuclear Information System (INIS)

    Zhang Wanchun; Li Sijin; Kang Chunsong; Hu Guang; Liu Jianzhong; Wang Jin; Kong Fanzhen

    2004-01-01

    Objective: Gated SPECT is a reproducible method for assessing left ventricular volume (LVV) and left ventricular ejection fraction (LVEF) from 99 Tcm-sestamibi ( 99 Tcm-MIBI) myocardial perfusion imaging studies. LVV and LVEF measurements by this approach correlate well with those obtained from other cardiovascular imaging techniques. Nevertheless, the lack of criteria for abnormal test findings has limited the potential clinical application of this new imaging technique. Methods: Gated myocardial perfusion SPECT with 99 Tcm-MIBI (QGSPECT) was performed on 96 individuals with a low Bayesian likelihood ( 99 Tcm-MIBI, 2-dimensional echocardiography was performed on 30 cases within 72 h. Results: The correlation between rest QGSPECT and 2-dimensional echocardiography was r=0.714 for LVEF (p 2 in men and ≤60 ml/m 2 in women, and ESV index ≤41 ml/m 2 in men and ≤25 ml/m 2 in women. Conclusion: (1) Quantification of LV function can be accurately evaluated using gated myocardial perfusion SPECT with 99 Tcm-MIBI, (2) Using a cohort of low-likelihood subjects, we generated sex-specific normal limits for LVV and LVEF for myocardial perfusion gated SPECT. These normal limits can now be evaluated prospectively for their potential clinical value. (authors)

  6. Serial assessment of left ventricular performance at rest and during bicycle exercise by ECG-gated myocardial perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kumita, Shin-ichiro; Cho, Keiichi; Nakajo, Hidenobu [Nippon Medical School, Tokyo (Japan)] [and others

    2002-07-01

    The present study evaluates left ventricular performance during exercise by ECG-gated myocardial perfusion SPECT with short-time data collection. The study population consisted of 10 healthy volunteers (Group N) and 9 patients with ischemic heart disease (Group I). Seven patients in Group I had a history of prior myocardial infarction. Rest ECG-gated SPECT was performed 40 min after an injection of Tc-99m-tetrofosmin (555-740 MBq). After resting data acquisition, Group N underwent up to two 5-min stages of exercise (75 and 125 watts) on a detachable bicycle ergometer. The Group I patients all underwent symptom-limited, maximal testing on the ergometer. ECG-gated SPECT data were acquired from both groups for 3 min at rest and during the last 3 min of each exercise stage. Significant increases occurred in LVEF from rest to peak stress in both groups (from 55.4{+-}5.8 to 66.6{+-}4.1% in group N, p<0.0001; from 49.0{+-}12.8 to 56.7{+-}13.8% in Group I, p<0.001). The LVESV values significantly decreased to peak stress in Group N (from 49.9{+-}13.1 to 37.8{+-}10.0 ml, p<0.0001), whereas LVEDV did not change (from 110.6{+-}18.9 to 112.0{+-}19.0 ml). In contrast, the LVESV values at rest and under peak stress were similar in Group I (from 52.6{+-}23.9 to 51.7{+-}31.4 ml) and LVEDV in Group I at peak exercise tended to increase (from 102.8{+-}36.7 to 111.3{+-}39.0 ml). The changes in LVESV from rest to peak stress were significantly different between Group N and I (-12.1{+-}6.3 vs. -0.9{+-}11.6 ml, p<0.02). ECG-gated SPECT with short-time data collection can assess left ventricular function during exercise and may offer useful information for evaluating patients with ischemic heart disease. (author)

  7. Evaluation of a decision support system for interpretation of myocardial perfusion gated SPECT.

    Science.gov (United States)

    Lomsky, Milan; Gjertsson, Peter; Johansson, Lena; Richter, Jens; Ohlsson, Mattias; Tout, Deborah; van Aswegen, Andries; Underwood, S Richard; Edenbrandt, Lars

    2008-08-01

    We have recently presented a decision support system for interpreting myocardial perfusion scintigraphy (MPS). In this study, we wanted to evaluate the system in a separate hospital from where it was trained and to compare it with a quantification software package. A completely automated method based on neural networks was trained for the interpretation of MPS regarding myocardial ischaemia and infarction using 418 MPS from one hospital. Features from each examination describing rest and stress perfusion, regional and global function were used as inputs to different neural networks. After the training session, the system was evaluated using 532 MPS from another hospital. The test images were also processed with the quantification software package Emory Cardiac Toolbox (ECTb). The images were interpreted by experienced clinicians at both the training and the test hospital, regarding the presence or absence of myocardial ischaemia and/or infarction and these interpretations were used as gold standard. The neural network showed a sensitivity of 90% and a specificity of 85% for myocardial ischaemia. The specificity for the ECTb was 46% (p neural network sensitivity for myocardial infarction was 89% and the specificity 96%. The corresponding specificity for the ECTb was 54% (p neural networks presents interpretations more similar to experienced clinicians compared to a conventional automated quantification software package. This study shows the feasibility of disseminating the expertise of experienced clinicians to less experienced physicians by the use of neural networks.

  8. Prognostic risk stratification of myocardial ischaemia evaluated by gated myocardial perfusion SPECT in patients with chronic kidney disease

    Energy Technology Data Exchange (ETDEWEB)

    Hatta, Tsuguru [Ohmihachiman Community Medical Center, Division of Nephrology, Department of Medicine, Shiga (Japan); Nishimura, Shigeyuki [Saitama Medical School Hospital, Division of Cardiology, Saitama (Japan); Nishimura, Tsunehiko [Kyoto Prefectural University of Medicine, Department of Radiology, Graduate School of Medical Science, Kyoto (Japan)

    2009-11-15

    The aim of this study was to identify useful predictors of cardiac events in patients with chronic kidney disease (CKD). Among 4,031 patients identified from the Japanese Assessment of Cardiac Events and Survival Study (J-ACCESS) database with suspected or known ischaemic heart disease, we selected 820 with an estimated glomerular filtration rate (eGFR) of < 60 ml/min per 1.73 m{sup 2}. A total of 75 cardiac events developed among these 820 patients. The incidence of cardiac events was higher in the group with a lower eGFR. Multivariate Cox analysis indicated that age, diabetes mellitus, end-systolic volume, summed stress score (SSS) and eGFR were predictors of cardiac events. Event rates of patients with SSS {>=} 9 were significantly higher in groups with lower eGFR values (< 40 and 40-49 ml/min). The SSS value ({>=} 9) is a reliable predictor of cardiac events and myocardial single photon emission computed tomography has incremental value for predicting cardiac events and survival in CKD. (orig.)

  9. Prognostic risk stratification of myocardial ischaemia evaluated by gated myocardial perfusion SPECT in patients with chronic kidney disease

    International Nuclear Information System (INIS)

    Hatta, Tsuguru; Nishimura, Shigeyuki; Nishimura, Tsunehiko

    2009-01-01

    The aim of this study was to identify useful predictors of cardiac events in patients with chronic kidney disease (CKD). Among 4,031 patients identified from the Japanese Assessment of Cardiac Events and Survival Study (J-ACCESS) database with suspected or known ischaemic heart disease, we selected 820 with an estimated glomerular filtration rate (eGFR) of 2 . A total of 75 cardiac events developed among these 820 patients. The incidence of cardiac events was higher in the group with a lower eGFR. Multivariate Cox analysis indicated that age, diabetes mellitus, end-systolic volume, summed stress score (SSS) and eGFR were predictors of cardiac events. Event rates of patients with SSS ≥ 9 were significantly higher in groups with lower eGFR values (< 40 and 40-49 ml/min). The SSS value (≥ 9) is a reliable predictor of cardiac events and myocardial single photon emission computed tomography has incremental value for predicting cardiac events and survival in CKD. (orig.)

  10. Development of 4D mathematical observer models for the task-based evaluation of gated myocardial perfusion SPECT

    Science.gov (United States)

    Lee, Taek-Soo; Frey, Eric C.; Tsui, Benjamin M. W.

    2015-04-01

    This paper presents two 4D mathematical observer models for the detection of motion defects in 4D gated medical images. Their performance was compared with results from human observers in detecting a regional motion abnormality in simulated 4D gated myocardial perfusion (MP) SPECT images. The first 4D mathematical observer model extends the conventional channelized Hotelling observer (CHO) based on a set of 2D spatial channels and the second is a proposed model that uses a set of 4D space-time channels. Simulated projection data were generated using the 4D NURBS-based cardiac-torso (NCAT) phantom with 16 gates/cardiac cycle. The activity distribution modelled uptake of 99mTc MIBI with normal perfusion and a regional wall motion defect. An analytical projector was used in the simulation and the filtered backprojection (FBP) algorithm was used in image reconstruction followed by spatial and temporal low-pass filtering with various cut-off frequencies. Then, we extracted 2D image slices from each time frame and reorganized them into a set of cine images. For the first model, we applied 2D spatial channels to the cine images and generated a set of feature vectors that were stacked for the images from different slices of the heart. The process was repeated for each of the 1,024 noise realizations, and CHO and receiver operating characteristics (ROC) analysis methodologies were applied to the ensemble of the feature vectors to compute areas under the ROC curves (AUCs). For the second model, a set of 4D space-time channels was developed and applied to the sets of cine images to produce space-time feature vectors to which the CHO methodology was applied. The AUC values of the second model showed better agreement (Spearman’s rank correlation (SRC) coefficient = 0.8) to human observer results than those from the first model (SRC coefficient = 0.4). The agreement with human observers indicates the proposed 4D mathematical observer model provides a good predictor of the

  11. Development of 4D mathematical observer models for the task-based evaluation of gated myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Lee, Taek-Soo; Frey, Eric C; Tsui, Benjamin M W

    2015-01-01

    This paper presents two 4D mathematical observer models for the detection of motion defects in 4D gated medical images. Their performance was compared with results from human observers in detecting a regional motion abnormality in simulated 4D gated myocardial perfusion (MP) SPECT images. The first 4D mathematical observer model extends the conventional channelized Hotelling observer (CHO) based on a set of 2D spatial channels and the second is a proposed model that uses a set of 4D space-time channels. Simulated projection data were generated using the 4D NURBS-based cardiac-torso (NCAT) phantom with 16 gates/cardiac cycle. The activity distribution modelled uptake of 99m Tc MIBI with normal perfusion and a regional wall motion defect. An analytical projector was used in the simulation and the filtered backprojection (FBP) algorithm was used in image reconstruction followed by spatial and temporal low-pass filtering with various cut-off frequencies. Then, we extracted 2D image slices from each time frame and reorganized them into a set of cine images. For the first model, we applied 2D spatial channels to the cine images and generated a set of feature vectors that were stacked for the images from different slices of the heart. The process was repeated for each of the 1,024 noise realizations, and CHO and receiver operating characteristics (ROC) analysis methodologies were applied to the ensemble of the feature vectors to compute areas under the ROC curves (AUCs). For the second model, a set of 4D space-time channels was developed and applied to the sets of cine images to produce space-time feature vectors to which the CHO methodology was applied. The AUC values of the second model showed better agreement (Spearman’s rank correlation (SRC) coefficient = 0.8) to human observer results than those from the first model (SRC coefficient = 0.4). The agreement with human observers indicates the proposed 4D mathematical observer model provides a good predictor of the

  12. Prediction of improvement in global left ventricular function in patients with chronic coronary artery disease and impaired left ventricular function: rest thallium-201 SPET versus low-dose dobutamine echocardiography

    International Nuclear Information System (INIS)

    Pace, L.; Salvatore, M.; Perrone-Filardi, P.; Dellegrottaglie, S.; Prastaro, M.; Crisci, T.; Ponticelli, M.P.; Piscione, F.; Chiariello, M.; Storto, G.; Della Morte, A.M.

    2000-01-01

    Accurate assessment of myocardial viability permits selection of patients who would benefit from myocardial revascularization. Currently, rest-redistribution thallium-201 scintigraphy and low-dose dobutamine echocardiography are among the most used techniques for the identification of viable myocardium. Thirty-one consecutive patients (all men, mean age 60±8 years) with chronic coronary artery disease and reduced left ventricular ejection fraction (31%±7%) were studied. Rest 201 Tl single-photon emission tomography (SPET), low-dose dobutamine echocardiography and radionuclide angiography were performed before revascularization. Radionuclide angiography and echocardiography were repeated after revascularization. An a/dyskinetic segment was considered viable on 201 Tl SPET when tracer uptake was >65%, while improvement on low-dose dobutamine echocardiography was considered a marker of viability. Increase in global ejection fraction was considered significant at ≥5%. In identifying viable segments, rest 201 Tl SPET showed higher sensitivity than low-dose dobutamine echocardiography (72% vs 53%, P 201 Tl SPET in group 1 than in group 2 (2.6±1.9 vs 0.6±1.2, P 201 Tl SPET and post-revascularization changes in ejection fraction (r=0.52, P 201 Tl SPET had a higher sensitivity (82% vs 53%, P=0.07) and showed a trend towards higher accuracy and specificity (77% vs 58%, and 71% vs 64%, respectively) as compared with low-dose dobutamine echocardiography. In conclusion, these findings suggest that when severely reduced global function is present, rest 201 Tl SPET evaluation of viability is more accurate than low-dose dobutamine echocardiography for the identification of patients who will benefit most from revascularization. (orig.)

  13. Nitrate-enhanced gated SPECT in patients with primary angioplasty for acute myocardial infarction: evidence of a reversible and nitrate-sensitive impairment of myocardial perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Djaballah, Wassila [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); UHP-INSERM ERI13, Nancy (France); Hopital de Brabois, Service de Medecine Nucleaire, CHU-Nancy, Vandoeuvre Cedex (France); Muller, Marc A.; Karcher, Gilles [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); Angioi, Michael [CHU-Nancy, Department of Cardiology, Nancy (France); UHP-INSERM U684, Nancy (France); Moulin, Frederic; Ethevenot, Gerard; Aliot, Etienne [CHU-Nancy, Department of Cardiology, Nancy (France); Codreanu, Andrei [UHP-INSERM ERI13, Nancy (France); CHU-Nancy, Department of Cardiology, Nancy (France); Mandry, Damien [UHP-INSERM ERI13, Nancy (France); CHU-Nancy, Department of Radiology, Nancy (France); Marie, Pierre Y. [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); UHP-INSERM U684, Nancy (France)

    2007-12-15

    Reperfusion of myocardial infarction (MI) leads to a reversible dysfunction of coronary vessels. We hypothesised that vasodilating drugs such as nitrates might improve sestamibi uptake within viable areas of recently reperfused MI, thereby enhancing prediction of subsequent improvements in perfusion and contractility. This study was aimed at assessing nitrate-enhanced sestamibi gated SPECT after MI reperfusion. Twenty-nine patients underwent rest followed by nitrate sestamibi gated SPECT at 9 {+-} 3 days after primary angioplasty for acute MI and at follow-up, 4-10 months later. Four MBq/kg of {sup 99m}Tc-sestamibi was injected at rest, and 12 MBq/kg after nitroglycerin spray. Follow-up improvements were documented for both perfusion (P+) and contractility (C+) in 18% of the 180 initially abnormal segments, in neither perfusion (P-) nor contractility (C-) in 44%, in contractility only (C+P-) in 16% and in perfusion only (C-P+) in 22%. Perfusion improvement was related to lower sestamibi uptake on baseline rest SPECT (P+: 42 {+-} 15% vs P-: 50 {+-} 15%, p = 0.001) and, moreover, to a higher increase between rest and nitrate uptake (P+: +9.5 {+-} 6.5% vs P-: +2.0 {+-} 5.9%, p < 0.001). Contractility improvement was related to sestamibi uptake on baseline nitrate SPECT (C+: 58 {+-} 15% vs C-: 38 {+-} 16%, p < 0.001), a variable enhancing the prediction provided by sestamibi uptake at rest (p < 0.05). The improvement in perfusion which is documented in the months following MI reperfusion is predicted by initial nitrate enhancement of sestamibi uptake, suggesting a mechanism of reversible vascular injury. In this particular setting, sestamibi uptake is a better predictor of contractility recovery when determined after nitrate administration rather than under conventional resting conditions. (orig.)

  14. Tl-201 Gated-SPECT: Post-exercise regional myocardial dysfunction in normoperfused territories as an indicator of TVD

    International Nuclear Information System (INIS)

    Bharathi Dasan, J.; Choudhury, S.; Hadi, M.; Kumar, R.; Malhotra, A.; Karthikeyan, G.

    2002-01-01

    Introduction: The identification of multivessel coronary artery disease has implications in management of patients with coronary artery disease (CAD). Non-gated Thallium-201 SPECT has a suboptimal sensitivity in the detection of individual coronary stenoses in patients with multi-vessel disease. The present study assesses the incremental value of regional post-stress myocardial dysfunction obtained with Thallium-201 gated SPECT studies (Tl-201gSPECT), in the detection of individual coronary stenoses in patients with triple-vessel coronary artery disease (TVD). Materials and Methods: Patients in group I, n= 25 (24 males, 1 female), aged 36 to 75 years (avg-56 + 9.3 yrs), with previously diagnosed or subsequently proven angiographic evidence of TVD, underwent same day exercise stress and redistribution myocardial Tl-201 gSPECT studies. An additional 15 patients (13 males, 2 females), aged 41 to 75 (avg. 58 + 9), who were angiographically normal (n=3) or had SVD (n=7) or DVD (n=5) were also recruited under the same protocol (group II). All patients underwent symptom limited treadmill exercise with the same protocol. The mean double product in group I was 22,985 + 4280 and the reasons for termination of exercise were THR in 14, dyspnoea in 7, fatigue in 2, ischemic ST segment changes in 1 and angina in 1. In group II, the mean double product was 24000 + 4326 and the reasons for termination of exercise were THR in 11, fatigue in 2, and chest pain in 1. The anterior and inferior myocardial walls were each divided into 3 segments, the septum and lateral wall into 6 and apex into 2. Segmental perfusion (SP), walls thickening (WT) and wall motion (WM) were then assessed. SP was scored from 0=normal to 4= absent. Emory Cardiac Toolbox software generated polar maps were used to score WT. WM was assessed qualitatively using scores of 0=normal to 4= dyskinesia. Where the endocardial border was not visualized, computer generated endocardial outlines were used to assess the wall

  15. Improvement of brain single photon emission tomography (SPET) using transmission data acquisition in a four-head SPET scanner

    International Nuclear Information System (INIS)

    Murase, Kenya; Tanada, Shuji; Inoue, Takeshi; Sugawara, Yoshifumi; Hamamoto, Ken

    1993-01-01

    Attenuation coefficient maps (μ-maps) are a useful way to compensate for non-uniform attenuation when performing single photon emission tomography (SPET). A new method was developed to record single photon transmission data and a μ-map for the brain was produced using a four-head SPET scanner. Transmission data were acquired by a gamma camera of opposite to a flood radioactive source attached to one of four gamma cameras in the four-head SPET scanner. Attenuation correction was performed using the iterative expectation maximization algorithm and the μ-map. Phantom studies demonstrated that this method could reconstruct the distribution of radioactivity more accurately than conventional methods, even for a severely non-uniform μ-map, and could improve the quality of SPET images. Clinical application to technetium-99m hexamethyl-propylene amine oxime (HMPAO) brain SPET also demonstrated the usefulness of this method. Thus, this method appears to be promising for improvement in the image quality and quantitative accuracy of brain SPET. (orig.)

  16. Comparison of 8-frame and 16-frame thallium-201 gated myocardial perfusion SPECT for determining left ventricular systolic and diastolic parameters.

    Science.gov (United States)

    Kurisu, Satoshi; Sumimoto, Yoji; Ikenaga, Hiroki; Watanabe, Noriaki; Ishibashi, Ken; Dohi, Yoshihiro; Fukuda, Yukihiro; Kihara, Yasuki

    2017-07-01

    The myocardial perfusion single photon emission computed tomography synchronized with the electrocardiogram (gated SPECT) has been widely used for the assessment of left ventricular (LV) systolic and diastolic functions using Quantitative gated SPECT. The aim of this study was to compare the effects of 8-frame and 16-frame thallium-201 (Tl-201) gated SPECT for determining LV systolic and diastolic parameters. The study population included 42 patients with suspected coronary artery disease who underwent gated SPECT by clinical indication. LV systolic and diastolic parameters were assessed on 8-frame and 16-frame gated SPECT. There were good correlations in end-diastolic volume (r = 0.99, p < 0.001), end-systolic volume (ESV) (r = 0.97, p < 0.001) and ejection fraction (EF) (r = 0.95, p < 0.001) between 8-frame and 16-frame gated SPECT. Bland-Altman plot showed a significant negative slope of -0.08 in EDV indicating a larger difference for larger EDV. Eight-frame gated SPECT overestimated ESV by 2.3 ml, and underestimated EF by -4.2% than 16-frame gated SPECT. There were good correlations in peak filling rate (PFR) (r = 0.87, p < 0.001), one third mean filling rate (r = 0.87, p < 0.001) and time to PFR (r = 0.61, p < 0.001) between 8-frame and 16-frame gated SPECT. Eight-frame gated SPECT underestimated PFR by -0.22 than 16-frame gated SPECT. Eight-frame gated SPECT estimated as much MFR/3 and TPFR as 16-frame gated SPECT. According to the data, the study suggested that 8-frame Tl-201 gated SPECT could underestimate systolic and/or diastolic parameter when compared with 16-frame gated SPECT.

  17. Long-term prognostic value of Tc-99m tetrofosmin myocardial gated-SPECT imaging in asymptomatic patients after percutaneous coronary intervention.

    Science.gov (United States)

    Georgoulias, Panagiotis; Demakopoulos, Nikolaos; Tzavara, Chara; Giannakou, Stavroula; Valotassiou, Varvara; Tsougos, Ioannis; Xaplanteris, Petros; Fezoulidis, Ioannis

    2008-11-01

    To evaluate the long-term prognostic value of Tc-99m tetrofosmin myocardial gated-SPECT in asymptomatic patients after coronary artery stenting. We included 246 consecutive patients in the study. All patients underwent exercise gated-single photon emission computed tomography (SPECT) myocardial imaging 5 to 7 months after percutaneous coronary intervention (PCI) and were followed for a mean period of 8.3 years (SD = 2.9). Myocardial scintigrams were evaluated calculating the summed stress score (SSS), summed rest score, and summed difference score (SDS) indexes. Cardiovascular death and nonfatal myocardial infarction were considered hard cardiac events, whereas late revascularization (>3 months after myocardial SPECT) procedures were considered to be soft events. Cox proportional hazard models were applied to evaluate the association between several variables and the investigated outcome. During the follow-up period, hard cardiac events occurred in 32 (13%) patients (cardiac death occurred in 12 patients and nonfatal myocardial infarction in 20 patients). In addition, 60 (24.4%) patients underwent a late revascularization procedure. When multiple Cox regression analysis was implied, the factors that remained significant in the final model for soft events were SSS, SDS, and angina during exercise testing. In addition, SSS, SDS, and left ventricular dilatation were independently associated with hard cardiac events as defined from the results of multiple analysis. However, SSS and SDS were the only independent predictors for both hard and soft events. Tc-99m tetrofosmin myocardial perfusion imaging (MPI), performed 6 months post-percutaneous coronary intervention, has an independent and powerful clinical value to predict hard and soft cardiac events in asymptomatic patients after PCI.

  18. Gender differences in detecting coronary artery disease with dipyridamole stress myocardial perfusion imaging using 99m-Tc sestamibi gated SPECT.

    OpenAIRE

    Majstorov, Venjamin; Pop Gjorceva, Daniela; Vaskova, Olivija; Vavlukis, Marija; Peovska, Irena; Maksimović, Jelena

    2005-01-01

    There are some specifics in the presentation of coronary artery disease (CAD) in women compared with men that may cause diagnostic pitfalls. The accuracy of noninvasive diagnostic testing in women tends to be lower than that in men. Stress myocardial perfusion imaging with 99m-Tc sestamibi gated SPECT is an accurate technique for detecting CAD. Only a few studies have compared dipyridamole stress imaging according to gender. The aim of the study was to compare the diagnostic value of dipyrida...

  19. Prognostic study of risk stratification among Japanese patients with ischemic heart disease using gated myocardial perfusion SPECT: J-ACCESS study

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, Tsunehiko [Kyoto Prefectural University of Medicine, Department of Radiology, Graduate School of Medical Science, Kyoto (Japan); Nakajima, Kenichi [Kanazawa University Graduate School of Medical Science, Department of Biotracer Medicine, Kanazawa (Japan); Kusuoka, Hideo [Osaka National Hospital, Osaka (Japan); Yamashina, Akira [Tokyo Medical University Hospital, Second Department of Internal Medicine, Tokyo (Japan); Nishimura, Shigeyuki [Saitama Medical School Hospital, Division of Cardiology, Saitama (Japan)

    2008-02-15

    Although the prognostic value of myocardial perfusion imaging using gated single photon emission computed tomography (SPECT) for predicting major cardiac events has been evaluated, little is known about the relevance of this procedure to the Japanese population. A total of 4,031 consecutive Japanese patients with suspected or confirmed ischemic heart diseases were registered at 117 hospitals in the Japanese Assessment of Cardiac Events and Survival Study by Quantitative Gated SPECT investigation. Gated stress/rest myocardial perfusion SPECT was performed and the patients were followed up for 3 years. Segmental perfusion scores and quantitative gated SPECT results were calculated. Major cardiac events were defined as cardiac death, nonfatal myocardial infarction, and severe heart failure. During the 3-year follow-up, cardiac death (n = 57) and nonfatal myocardial infarction (n = 39) occurred in 96 patients (2.4%/3 years) when hard events were the endpoints. When severe heart failure was included as an endpoint, major cardiac events that developed in 175 patients (4.3%/3 years) comprised cardiac death (n = 45), nonfatal myocardial infarction (n = 37), and severe heart failure (n = 93). Normal and severely abnormal summed stress score values were associated with low (2.31%/3 years) and high (9.21%/3 years) rates of major cardiac events, respectively. Rates of major cardiac events were significantly higher in patients with ejection fraction (EF) <45% than in those with EF 45% or higher (16.55 vs 2.94%/3 years; P < 0.001). The incidence of major cardiac events within 3 years was also significantly higher among patients with high end-systolic volumes. The major event rates were similar among nondiabetic patients with and diabetic patients without prior myocardial infarction at 5.06% and 5.73%/3 years, respectively. Cardiac event rates were significantly lower in the Japanese than in the USA and European populations. However, large myocardial perfusion defects and

  20. Clinical values of left ventricular mechanical dyssynchrony assessment by gated myocardial perfusion SPECT in patients with acute myocardial infarction and multivessel disease

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Sang-Geon; Park, Ki Seong; Kim, Jahae; Kim, Jong Sang; Song, Ho-Chun [Chonnam National University Hospital, Department of Nuclear Medicine, Gwang-ju (Korea, Republic of); Jabin, Zeenat; Kang, Sae-Ryung; Kwon, Seong Young; Jeong, Geum-Cheol; Song, Minchul; Min, Jung-Joon; Bom, Hee-Seung [Chonnam National University Hwasun Hospital, Department of Nuclear Medicine, Hwasun-gun, Jeonnam (Korea, Republic of); Cho, Jae Yeong; Kim, Hyun Kuk [Chonnam National University Hospital, Department of Cardiology, Gwang-ju (Korea, Republic of)

    2017-02-15

    The aim of this study was to evaluate the prognostic value of additional evaluation of left ventricular mechanical dyssynchrony (LVMD) by gated myocardial perfusion single-photon emission computed tomography (GMPS) in patients with acute myocardial infarction (MI) and multivessel disease. One hundred and nine acute MI patients with >50 % stenosis in at least one non-culprit artery who underwent GMPS within 2 weeks were enrolled. All patients underwent successful revascularization of the culprit arteries. Those with previous MI, atrial fibrillation, or frequent ventricular premature complexes, cardiac devices, significant patient motion, or procedure-related events were excluded. Phase standard deviation (PSD) and phase histogram bandwidth (PBW) were measured for assessment of LVMD. Patients were followed up for a median of 26 months after index MI, for composite major adverse cardiac events (MACE), which consisted with all-cause death, unplanned hospitalization due to heart failure and severe ventricular arrhythmias (sustained ventricular tachycardia or ventricular fibrillation). Independent predictors of MACE were evaluated. MACE occurred in 22 patients (20 %). Stress PSD (53.3 ± 17.3 vs. 35.3 ± 18.9 ; p <0.001), stress PBW (147.6 ± 54.6 vs. 96.8 ± 59.2 ; p = 0.001) and resting PBW (126.8 ± 37.5 vs. 96.6 ± 48.9 ; p = 0.001) were significantly higher in patients with MACE compared to those without. Multivariate analysis revealed that stress PSD ≥45.5 and stress PBW ≥126.0 were predictive of MACE, as well as suboptimal non-culprit artery revascularization (SNR) and renin-angiotensin system (RAS) blockade medication. Higher stress PSD and stress PBW were associated with poorer prognosis both in patients with and without SNR, and those with RAS blockade medication, but not in those without RAS blockade medication. LVMD measured by GMPS showed added prognostic value in acute MI with multivessel disease. GMPS could serve as a comprehensive evaluation imaging

  1. LV dyssynchrony as assessed by phase analysis of gated SPECT myocardial perfusion imaging in patients with Wolff-Parkinson-White syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Chun; Li, Dianfu; Miao, Changqing; Zhou, Yanli; Cao, Kejiang [First Affiliated Hospital of Nanjing Medical University, Department of Cardiology, Nanjing, Jiangsu (China); Feng, Jianlin [First Affiliated Hospital of Nanjing Medical University, Department of Nuclear Medicine, Nanjing, Jiangsu (China); Lloyd, Michael S. [Emory University School of Medicine, Division of Cardiology, Atlanta, GA (United States); Chen, Ji [Emory University School of Medicine, Department of Radiology and Imaging Sciences, Atlanta, GA (United States)

    2012-07-15

    The purpose of this study was to evaluate left ventricular (LV) mechanical dyssynchrony in patients with Wolff-Parkinson-White (WPW) syndrome pre- and post-radiofrequency catheter ablation (RFA) using phase analysis of gated single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). Forty-five WPW patients were enrolled and had gated SPECT MPI pre- and 2-3 days post-RFA. Electrophysiological study (EPS) was used to locate accessory pathways (APs) and categorize the patients according to the AP locations (septal, left and right free wall). Electrocardiography (ECG) was performed pre- and post-RFA to confirm successful elimination of the APs. Phase analysis of gated SPECT MPI was used to assess LV dyssynchrony pre- and post-RFA. Among the 45 patients, 3 had gating errors, and thus 42 had SPECT phase analysis. Twenty-two patients (52.4 %) had baseline LV dyssynchrony. Baseline LV dyssynchrony was more prominent in the patients with septal APs than in the patients with left or right APs (p < 0.05). RFA improved LV synchrony in the entire cohort and in the patients with septal APs (p < 0.01). Phase analysis of gated SPECT MPI demonstrated that LV mechanical dyssynchrony can be present in patients with WPW syndrome. Septal APs result in the greatest degree of LV mechanical dyssynchrony and afford the most benefit after RFA. This study supports further investigation in the relationship between electrical and mechanical activation using EPS and phase analysis of gated SPECT MPI. (orig.)

  2. LV dyssynchrony as assessed by phase analysis of gated SPECT myocardial perfusion imaging in patients with Wolff-Parkinson-White syndrome

    International Nuclear Information System (INIS)

    Chen, Chun; Li, Dianfu; Miao, Changqing; Zhou, Yanli; Cao, Kejiang; Feng, Jianlin; Lloyd, Michael S.; Chen, Ji

    2012-01-01

    The purpose of this study was to evaluate left ventricular (LV) mechanical dyssynchrony in patients with Wolff-Parkinson-White (WPW) syndrome pre- and post-radiofrequency catheter ablation (RFA) using phase analysis of gated single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). Forty-five WPW patients were enrolled and had gated SPECT MPI pre- and 2-3 days post-RFA. Electrophysiological study (EPS) was used to locate accessory pathways (APs) and categorize the patients according to the AP locations (septal, left and right free wall). Electrocardiography (ECG) was performed pre- and post-RFA to confirm successful elimination of the APs. Phase analysis of gated SPECT MPI was used to assess LV dyssynchrony pre- and post-RFA. Among the 45 patients, 3 had gating errors, and thus 42 had SPECT phase analysis. Twenty-two patients (52.4 %) had baseline LV dyssynchrony. Baseline LV dyssynchrony was more prominent in the patients with septal APs than in the patients with left or right APs (p < 0.05). RFA improved LV synchrony in the entire cohort and in the patients with septal APs (p < 0.01). Phase analysis of gated SPECT MPI demonstrated that LV mechanical dyssynchrony can be present in patients with WPW syndrome. Septal APs result in the greatest degree of LV mechanical dyssynchrony and afford the most benefit after RFA. This study supports further investigation in the relationship between electrical and mechanical activation using EPS and phase analysis of gated SPECT MPI. (orig.)

  3. Regional wall thickening in gated myocardial perfusion SPECT in a Japanese population: effect of sex, radiotracer, rotation angles and frame rates

    International Nuclear Information System (INIS)

    Akhter, Nasima; Nakajima, Kenichi; Okuda, Koichi; Matsuo, Shinro; Yoneyama, Tatsuya; Taki, Junichi; Kinuya, Seigo

    2008-01-01

    Gated single-photon emission computed tomography (SPECT) imaging of myocardium by 99m Tc and 201 Tl is used extensively to measure quantitative cardiac functional parameters. However, factors affecting normal values for myocardial functional parameters and population-specific standards have not yet been established. The aim of the study was to determine the effect of sex, radiotracer, rotation angles and frame rates on resting myocardial wall thickening (WT) and to develop a Japanese standard of normal values for WT. Data from a total of 202 patients with low possibility of having cardiac problems were collected from nine hospitals throughout Japan. Patients were divided into five groups according to study protocol, and WT was evaluated according to the 17-segment and four-region (basal, mid and apical regions and the apex) polar map distribution. WT was generally higher in women than in men irrespective of the use of radiotracers, rotation angles or frame rates, and the difference was highly significant in the mid and apical regions. In any protocol used, resting myocardial thickening in the apex was higher than in the mid and apical regions, and thickening was lowest in the basal region, suggesting heterogeneous regional myocardial thickening (%) in normal subjects. Different rotation angles showed no significant change on WT, but different frame rates and tracers showed significant WT change in both sexes. Percent thickening of the myocardium was significantly higher in imaging by 99m Tc-labelled tracers than in 201 Tl. Sex, radiotracers and frame rates had a significant effect on myocardial thickening, and the importance of population-specific standards should be emphasized. A normal database can serve as a standard for gated SPECT evaluation of myocardial thickening in a Japanese population and might be applicable to Asian populations having a similar physique. (orig.)

  4. Acquisition of linograms in SPET: implementation and benefits

    International Nuclear Information System (INIS)

    Walrand, Stephan; Pauwels, Stanislas; Dulmen, Aad van; Rossem, Henk van

    2002-01-01

    Compared with other tomographic modalities, single-photon emission tomography (SPET), the most widely used tomographic modality in nuclear medicine, suffers from poor quality image since the collimator stops 99.99% of the emitted gamma rays reaching the detector. This paper describes a new SPET acquisition modality using a very short focal length (12.5 cm) fan-beam collimator and a very short transverse field of view detector (25 cm). The detector moves along at least two linear orthogonal orbits in such a way that the focal line travels through the source target. This linear orbit acquisition (LOrA) generates linograms forming a complete set of tomographic data, i.e. sufficient to exactly reconstruct the activity map using a modified filtered back-projection algorithm. In contrast to the classical fan-beam tomography, truncation is not a problem, even when the source transverse size is much larger than the detector transverse size. When the collimator hole length/diameter ratio is adapted to obtain a spatial resolution similar to that of classical SPET, LOrA SPET offers an improvement in sensitivity by a factor of about 2.5 for a 20-cm source size. This improvement is achieved with a detector that is half as large, and thus half as expensive. As with classical fan-beam SPET, the sensitivity increases further if the target size decreases. When fitting the collimator to obtain a similar sensitivity to that of classical SPET, a significant improvement in spatial resolution is obtained. (orig.)

  5. [Rest gated-SPECT myocardial perfusion post (99m)Tc-MIBI injection in a patient with acute chest pain and with no medical history of ischemic heart disease].

    Science.gov (United States)

    Negre-Busó, M; Muntaner-Muñoz, L; Rubió-Rodríguez, A; Marin-Buriticá, A; Ferran-Sureda, N; Bassaganyas-Vilarrasa, J

    2015-01-01

    Gated-SPECT myocardial perfusion imaging is a widely used technique indicated for assessment of patients with no clear diagnosis of ischemic heart disease. Early rest gated-SPECT myocardial perfusion study in patients with acute chest pain has high sensitivity and high negative predictive value for ruling out coronary disease. We report a case of a patient admitted for the study of her chest pain. She underwent a myocardial perfusion stress-rest whose interpretation could have been equivocal due to the clinical status of the patient during the injection of the radiotracer. Copyright © 2014 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  6. Comparison of Gated SPECT Myocardial Perfusion Imaging with Echocardiography for the Measurement of Left Ventricular Volumes and Ejection Fraction in Patients With Severe Heart Failure

    Science.gov (United States)

    Shojaeifard, Maryam; Ghaedian, Tahereh; Yaghoobi, Nahid; Malek, Hadi; Firoozabadi, Hasan; Bitarafan-Rajabi, Ahmad; Haghjoo, Majid; Amin, Ahmad; Azizian, Nasrin; Rastgou, Feridoon

    2015-01-01

    Background: Gated single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) is known as a feasible tool for the measurement of left ventricular ejection fraction (EF) and volumes, which are of great importance in the management and follow-up of patients with coronary artery diseases. However, considering the technical shortcomings of SPECT in the presence of perfusion defect, the accuracy of this method in heart failure patients is still controversial. Objectives: The aim of the present study was to compare the results from gated SPECT MPI with those from echocardiography in heart failure patients to compare echocardiographically-derived left ventricular dimension and function data to those from gated SPECT MPI in heart failure patients. Patients and Methods: Forty-one patients with severely reduced left ventricular systolic function (EF ≤ 35%) who were referred for gated SPECT MPI were prospectively enrolled. Quantification of EF, end-diastolic volume (EDV), and end-systolic volume (ESV) was performed by using quantitative gated spect (QGS) (QGS, version 0.4, May 2009) and emory cardiac toolbox (ECTb) (ECTb, revision 1.0, copyright 2007) software packages. EF, EDV, and ESV were also measured with two-dimensional echocardiography within 3 days after MPI. Results: A good correlation was found between echocardiographically-derived EF, EDV, and ESV and the values derived using QGS (r = 0.67, r = 0.78, and r = 0.80 for EF, EDV, and ESV, respectively; P echocardiography. ECTb-derived EDV was also significantly higher than the EDV measured with echocardiography and QGS. The highest correlation between echocardiography and gated SPECT MPI was found for mean values of ESV different. Conclusions: Gated SPECT MPI has a good correlation with echocardiography for the measurement of left ventricular EF, EDV, and ESV in patients with severe heart failure. However, the absolute values of these functional parameters from echocardiography and gated

  7. Postoperative Functional Outcome After Off-Pump Versus On-Pump Coronary Artery Bypass Grafting Using Gated Myocardial SPECT: A Comparison by Propensity Score Analysis

    International Nuclear Information System (INIS)

    Lee, Jong Jin; Paeng, Jin Chul; Lee, Dong Soo; Kim, Ki Bong; Chung, June Key; Lee, Myung Chul; Kang, Won Jun

    2010-01-01

    We evaluated the short-term and mid-term differences in perfusion and function after off-pump and on-pump coronary artery bypass grafting (CABG) using gated myocardial single photon emission computed tomography. A total of 70 patients with coronary artery disease who underwent CABG were included based on the propensity score matching results from 165 patients. Thirty-five patients underwent off-pump and 35 patients on-pump CABG. Rest 201 TI/dipyridamole stress 99m Tc-methoxyisobutylisonitrile gated single photon emission computed thermographs were performed preoperatively and postoperatively at short-term (103±23 days after surgery) and mid-term follow-up (502±111 days after surgery). Changes in left ventricular ejection fraction, end systolic volume, stress and rest segmental perfusion, and segmental wall thickening were compared between the two groups. The segments with preoperative rest 201 T1 uptake under 60% of maximum uptake were included in the segmental analysis. Left ventricular ejection fraction (P=0.001) and end systolic volume (P=0.008) showed significant improvement in both groups. There were no significant short-term and mid-term differences between the two groups in terms of left ventricular ejection fraction (P=0.309) and end systolic volume (P=0.938). Likewise, segmental rest (P=0.178) and stress perfusion (P=0.071), and systolic wall thickening (P=0.241) showed significant improvement in both groups with similar time courses. Off-pump CABG resulted in significant improvements in left ventricular ejection fraction, end systolic volume, and regional myocardial perfusion and function that are comparable to on-pump CABG at short-term and mid-term. Gated myocardial SPECT successfully revealed that off-pump CABG is as good as on-pump CABG from the viewpoint of myocardial perfusion and function.

  8. Low dose prospective ECG-gated delayed enhanced dual-source computed tomography in reperfused acute myocardial infarction comparison with cardiac magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Wang Rui, E-mail: rui_wang1979@yahoo.cn [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Zhang Zhaoqi, E-mail: zhaoqi5000@vip.sohu.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Xu Lei, E-mail: leixu2001@hotmail.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Ma Qin, E-mail: tel1367@gmail.com [Department of Emergency, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); He Yi, E-mail: heyi139@sina.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Lu Dongxu, E-mail: larry.hi@163.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Yu Wei, E-mail: yuwei02@gmail.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Fan Zhanming, E-mail: fanzm120@tom.com [Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China)

    2011-11-15

    Purpose: To determine whether prospective electrocardiogram (ECG)-gated delayed contrast-enhanced dual-source computed tomography (DCE-DSCT) can accurately delineate the extension of myocardial infarction (MI) compared with delayed enhanced cardiac MR (DE-MR). Material and methods: Eleven patients were examined using dual-source CT and cardiac MR in 2 weeks after a first reperfused MI. DCE-DSCT scan protocol was performed with prospective ECG-gating sequential scan model 7 min after contrast administration. In a 17-model, infarcted myocardium detected by DE-MR was categorized as transmural and subendocardial extension. Segment of infarcted location and graded transmurality were compared between DCE-MDCT and DE-MR. Results: In all eleven patients, diagnostic quality was obtained for depicting delayed enhanced myocardium. Agreement between DCE-DSCT and MR was good on myocardial segment based comparison (kappa = 0.85, p < 0.001), and on transmural and subendocardial infarction type comparison (kappa = 0.82, p < 0.001, kappa = 0.52, p < 0.001, respectively). CT value was higher on infarcted region than that of normal region (100.02 {+-} 9.57 HU vs. 72.63 {+-} 7.32 HU, p < 0.001). Radiation dose of prospectively ECG-gating protocol were 0.99 {+-} 0.08 mSv (0.82-1.19 mSv). Conclusions: Prospective ECG-gated DCE-DSCT can accurately assess the extension and the patterns of myocardial infarction with low radiation dose.

  9. Radionuclide imaging for assessment of myocarditis and postmyocarditic state in infant and children. Thallium-201 myocardial imaging and technetium-99m-HSA gated equilibrium ventriculography.

    Science.gov (United States)

    Saji, T; Matsuo, N; Hashiguchi, R; Sato, K; Umezawa, T; Morishita, K; Yamazaki, J; Kawamura, Y; Okuzumi, K; Yabe, Y

    1985-05-01

    T1-201 myocardial imaging and Tc-99m-HSA gated equilibrium ventriculography were performed in 1 infant and 11 children between 2 months old and 12 years old with myocarditis. The time of first evaluation was between 1 week and 13 months after the onset. Their clinical manifestations were congestive heart failure in 2 patients, pericardial effusion in 2 patients, syncope in 1 patient, convulsions in 1 patient and palpitations in 7 patients. Significant elevation of virus antibody titer was demonstrated in 6 patients. A perfusion defect was observed with T1-201 imaging in 9 of 12 patients with myocarditis. A right ventricular image was observed in 5 patients. A reduced LVEF was present in 4 patients and a reduced RVEF was found in 2 patients. Cardiac catheterization was performed in 8 patients and an endomyocardial biopsy was done in 7. The myocardial specimens revealed postmyocarditic pathological changes upon microscopic evaluation. No coronary artery obstructive or stenotic lesions were observed in these patients. T1-201 myocardial imaging is a useful non-invasive technique for evaluating the cardiac performance and myocardial damage in acute myocarditis and the postmyocarditic state. We conclude that T1-201 uptake of myocardium is dependent upon both regional coronary perfusion and the activity of myocardial cells in patients with myocarditis and in the postmyocarditic state.

  10. Comparison of Hemodynamic Effects and Negative Predictive Value of Normal Adenosine Gated Myocardial Perfusion Scan With or Without Caffeine Abstinence

    International Nuclear Information System (INIS)

    Zaman, Maseeh uz; Fatima, Nosheen; Zaman, Areeba; Zaman, Unaiza; Tahseen, Rabia

    2016-01-01

    For vasodilator stress, myocardial perfusion imaging (MPI) with at least 12-h caffeine abstinence is recommended, as it attenuates cardiovascular hyperemic response of adenosine and dipyridamole. However, many published conflicting results have shown no significant effect upon perfusion abnormalities in MPI performed without caffeine abstinence. The aim of this study was to compare the hemodynamic changes and negative predictive value (NPV) of normal MPIs with adenosine stress performed with or without caffeine abstinence. This was a prospective study that accrued 50 patients from May 2013 till September 2013 and followed till November 2014. These patients had a normal adenosine-gated MPI (GMPI) with technetium-99m methoxy isobutyl isonitrile ( 99m Tc-MIBI) after 12-h caffeine abstinence (no-caffeine). Next day, all patients had a repeat adenosine stress within 60 min after ingestion of a cup of coffee (about 80 mg of caffeine) followed by no MPI in 30 patients due to concern about radiation dose (prior-caffeine adenosine—no MPI; group A). Twenty patients opted for a repeat MPI (prior-caffeine adenosine—MPI; group B). Adenosine-induced hemodynamic response and NPV of the normal MPI with no-caffeine and prior-caffeine protocols were compared. The mean age of the study cohort was 57 ± 9 years with a male-to-female ratio of 76:24% and mean body mass index (BMI) of 26.915 ± 4.121 kg/m 2 . Prevalence of hypertension, diabetes, dyslipidemia, and positive family history were 76%, 20%, 22%, and 17%, respectively. Comparison of group A with group B revealed no significant difference in demographic parameters, hemodynamic or electrocardiography (ECG) parameters, or left ventricular (LV) function parameters during adenosine intervention with prior-caffeine and no-caffeine protocols. During the follow-up, no fatal myocardial infarction (MI) was reported but 6 nonfatal MIs were reported based upon the history of short hospitalization for chest pain but without biochemical

  11. Incremental Diagnostic Performance of Combined Parameters in the Detection of Severe Coronary Artery Disease Using Exercise Gated Myocardial Perfusion Imaging.

    Directory of Open Access Journals (Sweden)

    Chia-Ju Liu

    Full Text Available Myocardial perfusion imaging (MPI using gated single-photon emission tomography (gSPECT may underestimate the severity of coronary artery disease (CAD. This study aimed to evaluate the significance of combined parameters derived from gSPECT, as well as treadmill stress test parameters, in the detection of severe CAD.A total of 211 consecutive patients referred for exercise MPI between June 2011 and June 2013 (who received invasive coronary angiography within six months after MPI were retrospectively reviewed. Exercise MPI was performed with Bruce protocol and 201Tl injected at peak exercise. Gated SPECT was performed using a cadmium-zinc-telluride camera and processed by QPS/QGS software. Perfusion defect abnormalities such as sum stress score (SSS; sum difference score, algorithm-derived total perfusion deficits, transient ischemic dilatation ratios of end-diastolic volumes and end-systolic volumes, post-stress changes in ejection fraction, and lung/heart ratio (LHR were calculated. Treadmill parameters, including ST depression (STD at the 1st and 3rd minutes of recovery stage (1'STD and 3'STD, maximal STD corrected by heart rate increment (ST/HR, heart rate decline in 1st and 3rd minutes of recovery stage, recovery heart rate ratio (HR ratio, systolic and mean blood pressure ratios (SBP ratio and MAP ratio during recovery phase were recorded. Diagnostic performances of these parameters were analyzed with receiver operating characteristic (ROC analysis and logistic regression for detection of left main (≥ 50% or 3-vessel disease (all ≥ 70% luminal stenosis on invasive angiography.Among various MPI and treadmill parameters used for detection of severe CAD, SSS and ST/HR had the highest AUC (0.78, 0.73, p = NS and best cut-off values (SSS > 6, ST/HR > 17.39 10-2mV/bpm, respectively. By univariate logistic regression, all parameters except 1'HRR, 3'HRR, SBP and MAP ratios increased the odds ratio of severe CAD. Only increased L/H ratio, 3'STD

  12. Prognostic significance of stress myocardial ECG-gated perfusion imaging in asymptomatic patients with diabetic chronic kidney disease on initiation of haemodialysis

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Mitsuru; Kondo, Chisato; Kobayashi, Hideki; Kusakabe, Kiyoko [Tokyo Women' s Medical University, School of Medicine, Department of Radiology, Shinjuku-ku, Tokyo (Japan); Babazono, Tetsuya [Tokyo Women' s Medical University, School of Medicine, Diabetes Centre, Shinjuku-ku, Tokyo (Japan); Nakajima, Takatomo [Tokyo Women' s Medical University, School of Medicine, Department of Cardiology, Shinjuku-ku, Tokyo (Japan)

    2009-08-15

    Diabetic patients with chronic kidney disease (CKD) frequently develop cardiac events within several years of the initiation of haemodialysis. The present study assesses the prognostic significance of stress myocardial ECG-gated perfusion imaging (MPI) in patients with diabetic CKD requiring haemodialysis. Fifty-five asymptomatic patients with diabetic stage V CKD and no history of heart disease scheduled to start haemodialysis were enrolled in this study (56{+-}11 years old; 49 with type 2 diabetes mellitus). All patients underwent {sup 201}Tl stress ECG-gated MPI 1 month before or after the initiation of haemodialysis to assess myocardial involvement. We evaluated SPECT images using 17-segment defect scores graded on a 5-point scale, summed stress score (SSS) and summed difference scores (SDS). The patients were followed up for at least 2 years (42{+-}15 months) to determine coronary intervention (CI) and heart failure (HF) as soft events and acute myocardial infarction (AMI) and all causes of deaths as hard events. The frequencies of myocardial ischaemia, resting perfusion defects, low ejection fraction and left ventricular (LV) dilatation were 24,20,29 and 49%, respectively. Ten events (18%) developed during the follow-up period including four CI, one HF, one AMI and four sudden deaths. Multivariate Cox analysis selected SDS (p=0.0011) and haemoglobin A{sub 1c} (HbA{sub 1c}) (p=0.0076) as independent prognostic indicators for all events. Myocardial ischaemia, in addition to glycaemic control, is a strong prognostic marker for asymptomatic patients with diabetic CKD who are scheduled to start haemodialysis. Stress MPI is highly recommended for the management and therapeutic stratification of such patients. (orig.)

  13. The consequences of a new software package for the quantification of gated-SPECT myocardial perfusion studies

    International Nuclear Information System (INIS)

    Veen, Berlinda J. van der; Dibbets-Schneider, Petra; Stokkel, Marcel P.M.; Scholte, Arthur J.

    2010-01-01

    Semiquantitative analysis of myocardial perfusion scintigraphy (MPS) has reduced inter- and intraobserver variability, and enables researchers to compare parameters in the same patient over time, or between groups of patients. There are several software packages available that are designed to process MPS data and quantify parameters. In this study the performances of two systems, quantitative gated SPECT (QGS) and 4D-MSPECT, in the processing of clinical patient data and phantom data were compared. The clinical MPS data of 148 consecutive patients were analysed using QGS and 4D-MSPECT to determine the end-diastolic volume, end-systolic volume and left ventricular ejection fraction. Patients were divided into groups based on gender, body mass index, heart size, stressor type and defect type. The AGATE dynamic heart phantom was used to provide reference values for the left ventricular ejection fraction. Although the correlations were excellent (correlation coefficients 0.886 to 0.980) for all parameters, significant differences (p < 0.001) were found between the systems. Bland-Altman plots indicated that 4D-MSPECT provided overall higher values of all parameters than QGS. These differences between the systems were not significant in patients with a small heart (end-diastolic volume <70 ml). Other clinical factors had no direct influence on the relationship. Additionally, the phantom data indicated good linear responses of both systems. The discrepancies between these software packages were clinically relevant, and influenced by heart size. The possibility of such discrepancies should be taken into account when a new quantitative software system is introduced, or when multiple software systems are used in the same institution. (orig.)

  14. Quantification of left ventricular regional functions using ECG-gated myocardial perfusion SPECT. Validation of left ventricular systolic functions

    International Nuclear Information System (INIS)

    Yamamoto, Akira; Takahashi, Naoto; Iwahara, Shin-ichiro; Munakata, Kazuo; Hosoya, Tetsuo

    2006-01-01

    We have developed a program to quantify regional left ventricular (LV) function and wall motion synchrony using electrocardiogram (ECG)-gated myocardial perfusion SPECT (MPS). This preliminary study was undertaken to validate the use of this program for estimating regional LV systolic function. Patients were subjected to MPS by 99m Tc-sestamibi at rest. The study included 20 patients who were confirmed to have a low probability of coronary artery disease (LPG; low probability group), 19 heart disease patients who were examined by MPS and equilibrium radionuclide angiography (ERNA) (ERG; ERNA group), and 24 patients who were examined by MPS and 2-dimensional echocardiography (2DE) (2DEG; 2DE group). The values of the ejection fraction (EF) and peak ejection rate (PER) were estimated. The global functions evaluated by this program were compared with those obtained by ERNA in the ERG. For regional assessment, the reference values of the functional indices were obtained for 17 LV segments in LPG. The Z score, (reference average value of the segment-patient's value of the segment)/reference standard deviation of the segment, was used for the evaluation of regional functions; a score equal to or greater than 2 was defined as abnormal. Semiquantitative visual interpretation of 2DE was used as the standard to assess wall motion. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of these criteria and the relationship between 2DE grading and Z scoring were validated in 2DEG. The values of the global EF and PER evaluated by this program correlated with those determined by ERNA (r=0.76 and 0.58, respectively; p -10 ). The potential of this program to quantify the regional systolic function was validated. (author)

  15. Prognostic significance of stress myocardial gated SPECT among Japanese patients referred for coronary angiography: A study of data from the J-ACCESS database

    International Nuclear Information System (INIS)

    Momose, Mitsuru; Nakajima, Kenichi; Nishimura, Tsunehiko

    2009-01-01

    The J-ACCESS [Japanese investigation of prognosis based on gated single photon emission computed tomography (SPECT)] study found that quantitative gated myocardial SPECT (QGS) is valuable for predicting the prognosis of Japanese patients with known or suspected ischaemic heart disease. The present study evaluates the incremental prognostic value of myocardial perfusion imaging (MPI) with QGS among patients referred for coronary angiography (CAG). Among 4,031 Japanese patients registered at 117 hospitals for the J-ACCESS study, we selected 1,011 who underwent CAG within 3 months before or after MPI with QGS. Summed stress, rest and difference scores (SSS, SRS and SDS) were generated from myocardial perfusion images using a 20-segment scoring system. Myocardial ischaemia was judged visually. End-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were determined by QGS. Numbers of diseased (> 75% stenosis) coronary vessels (CDV) were assessed by CAG. All patients were followed up for 3 years to determine cardiac events (CE) including cardiac death, non-fatal myocardial infarction and severe heart failure. Univariate and multivariate analyses of prognostic ability included age, cardiac risk factors (hypertension, hyperlipidaemia, diabetes mellitus and prior myocardial infarction), angiographic findings and the QGS parameters as independent variables. Cardiac events occurred more frequently with increasing numbers of coronary vessel lesions (p=0.0016). Cox univariate analysis revealed that diabetes, CDV, SSS, SDS, EDV, ESV and EF were significant predictors (Wald χ 2 =5.99, 12.9, 8.39, 9.11, 35.5, 42.1 and 31.1, respectively), whereas multivariate analysis selected only ESV and SDS as significant predictors (Wald χ 2 =36.4, 8.4; p = 0.0038, p < 0.001). MPI with QGS, especially with gated functional data, has incremental prognostic value in addition to angiographic findings. MPI with QGS findings predominantly contribute to the prediction of

  16. SPET brain imaging with 201 diethyldithiocarbamate in acute ischaemic stroke

    NARCIS (Netherlands)

    de Bruïne, J. F.; Limburg, M.; van Royen, E. A.; Hijdra, A.; Hill, T. C.; van der Schoot, J. B.

    1990-01-01

    Thirty-five patients with acute ischaemic stroke were studied within 24 h after hospital admission with thallium 201 diethyldithiocarbamate single photon emission tomography (201Tl-DDC SPET) and X-ray computed tomography (CT). 201Tl-DDC is a non-redistributing agent that allows postponed imaging

  17. Assessment of left ventricular ejection fraction by gated blood pool scintigraphy on early and late phase from the onset of acute myocardial infarction

    International Nuclear Information System (INIS)

    Nakashima, Yoshiharu; Fukuzaki, Hisashi; Minamiji, Katsumi; Kida, Toru; Okada, Toshio; Yamada, Shigenobu; Goto, Takeshi; Maeda, Kazumi; Yoshida, Yutaka.

    1984-01-01

    To evaluate the change of left ventricular function after the onset of acute myocardial infarction, gated blood pool scintigraphy was performed in 19 patients on early and late phase (6 days and 1 month on the average). There was a difference in left ventricular ejection fraction (LVEF) between patients with anterior and inferior myocardial infarction. Patients with anterior infarction indicated low value of LVEF (31+-7%) on acute phase and its value was increased on chronic phase (37+-8%), whereas patients with inferior infarction had higher value of LVEF not only on acute phase but also on chronic phase (54+-9%→57+-10%), than those with anterior infarction. Left ventricular volume was larger in anterior group than in inferior group and tended to become smaller on chronic phase. In 4 of 10 cases with anterior infarction, a significant improvement of LVEF was found from 28+-6% to 43+-5%, but in 6 cases LVEF was unchanged during the same period. In 3 cases out of improved group, it was demonstrated angiographically that the collateral vessels were developed. It was, thus, suggested that collateral vessels may play an important role in the recovery of myocardial ischemia and wall motion abnormality in the marginal zone of infarcted area. From these results, we concluded that left ventricular function changed serially in most patients from the early phase to the late phase after the onset of acute myocardial infarction. (author)

  18. Prognostic value of Tc-99m tetrofosmin myocardial perfusion gated SPECT in patients with diabetes mellitus and suspected coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Marcia Maria Sales dos; Pantoja, Mauricio da Rocha; Cwajg, Eduardo [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil); CINTILAB, Rio de Janeiro, RJ (Brazil); E-mail: mmsales@oi.com.br

    2008-01-15

    Background: The cardiovascular disease is the main cause of death among diabetic patients, which makes it crucial to identify the individuals at higher risk of cardiovascular events. Objective: To evaluate the prognostic value of scintigraphy with gated single photon emission computed tomography (SPECT) in patients with diabetes mellitus (DM) and suspected coronary artery disease. Methods: Retrospective study with 232 diabetic patients submitted to scintigraphy with gated SPECT. Perfusion Gated SPECT (scores and number of altered segments) as well as ventricular function parameters (ejection fraction, left ventricle volume and contractility) were evaluated. Cardiac death, acute ischemic coronary syndrome, revascularization procedures or encephalic vascular accident were considered future cardiovascular events. The uni- and multivariate analyses were carried out by the multiple logistic regression model (p< 0.05). Results: At the univariate analysis, age (p=0.02), chest angina (p=0.01), insulin therapy (p=0.02), myocardial perfusion abnormalities (p<0.0001), the number of segments involved (p=0.0001), the perfusion scores (p=0.0001), the ejection fraction (p=0.004), the final systolic volume (p=0.03) and the finding of segmental alteration at the LV contractility (p<0.0001) were associated with future events at the univariate analysis. At the multivariate analysis, the male sex (p=0.007), age (p=0.03), angina (p=0.001), insulin therapy (p=0.007) and the SDS {>=} 3 (p=0.0001), and the number of altered segments {>=} 3 (p=0.0001) were predictors of cardiovascular events. Conclusion: The myocardial scintigraphy with gated SPECT adds independent information to the stratification of the risk of future cardiovascular events in patients with DM and suspected coronary artery disease. (author)

  19. Determinants of the response of left ventricular ejection fraction to vasodilator stress in electrocardiographically gated {sup 82}rubidium myocardial perfusion PET

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Tracy L.Y.; Merrill, Jennifer; Bengel, Frank M. [Johns Hopkins University, Department of Radiology and Radiological Sciences, Division of Nuclear Medicine, Baltimore, MD (United States); Volokh, Lana [GE Healthcare, Haifa (Israel)

    2008-02-15

    Myocardial perfusion imaging with {sup 82}Rb PET allows for ECG-gated studies to be obtained early after radiotracer injection, capturing ventricular function close to peak pharmacologic action of dipyridamole. This is different from gated SPECT and may potentially provide additional diagnostic information. We sought to identify potential correlates of the PET-derived ejection fraction response to vasodilator stress. One hundred ten consecutive patients undergoing {sup 82}Rb PET myocardial perfusion imaging during evaluation for coronary artery disease were included. Using a GE Discovery STRx PET-CT scanner, ECG-gated images (eight bins) were obtained at rest and 4 min after dipyridamole infusion, 90 s after infusion of 1,480-2,220 MBq of {sup 82}Rb. Summed rest, stress, and difference scores (SRS, SSS, and SDS) were determined using a five-point scoring system and 20-segment model. Ejection fraction was calculated using automated QGS software. Significant reversibility (SDS {>=} 4) was found in 23 patients (21%). Mean LVEF in all patients was 47 {+-} 13% at rest and 53 {+-} 13% during dipyridamole. LVEF increased in 89 patients, and decreased in 17 patients during vasodilation. The change in LVEF was inversely correlated with SDS (r = -0.26; p = 0.007). Additionally, it was inversely correlated with resting LVEF (r = -0.20; p = 0.03) and SSS (r = -0.25; p = 0.009). No significant correlations were observed with SRS, heart rate, blood pressure, age, hypertension, hypercholesterolemia, or pretest likelihood of disease. At multivariate regression analysis, SDS was an independent predictor of the change in LVEF. Gated {sup 82}Rb PET during pharmacologic stress allows for assessment of the functional response to vasodilation. The magnitude of LVEF increase is determined by stress perfusion/reversible perfusion defects. Functional response to hyperemia may thus be incorporated in future evaluations of diagnostic and prognostic algorithms based on {sup 82}Rb PET. (orig.)

  20. Expected utility value of Tc-99m sestamibi rest gated myocardial perfusion SPECT imaging at the emergency room compared to troponins and non-guided hospitalization

    International Nuclear Information System (INIS)

    Merlano, S.; Rodriguez, E.; Murgueitio, R.

    2006-01-01

    The evaluation of acute chest pain at the emergency room remains a challenge. The expected utility value of the Tc- 99m sestamibi rest gated myocardial perfusion SPECT imaging (rest gated SPECT) in patients with typical or atypical chest pain and normal or non diagnostic electrocardiogram was evaluated. Three decision models were developed. In the first model; Decision Tree-A, non guided hospitalization and rest gated SPECT were analyzed. The second model; Decision Tree -B, analysed Troponins within 0-12 hrs and hospitalization, and the third model, i.e., Decision Tree -C, analyzed Troponins and rest gated SPECT. Patients and outcomes were categorised as follows: 1. High risk patients, those with positive scans who experienced adverse cardiac events (True positive); 2. Patients with positive results who did not have an acute event (False positive); 3. Negative results without an event (True negative); 4. High risk patients hospitalized who did not have acute event (False positive) and 5. Low risk patients with proven acute coronary event (False negative). We incorporated probabilities for measuring the favorable and unfavorable outcomes, using a scale of 0 to 1. Expected utilities were calculated using the software Tree Age through the roll-back method. The overall expected utility of rest gated SPECT to decide hospitalization was 0.79, while the non-guided hospitalization was 0 .45. The highest expected utility encountered was 0.91 for the decision of no hospitalization based on a negative rest perfusion scan result with a favorable outcome. When troponins and hospitalization were compared, the expected utility value observed for troponin was 0.59, greater than that of 0.47 for the symptom based hospitalization. Finally, when the two alternatives troponins and myocardial perfusion imaging were compared, the greatest expected utility value observed was with the nuclear cardiology procedure with an expected utility value of 0.81, as compared to that of 0.60 for the

  1. Comparison of Nitrate-augmented resting gated 99mTc-Sestamibi imaging with Low Dose Dobutamine SPECT for the detection of Myocardial Viability

    International Nuclear Information System (INIS)

    Parameswaran, R.V.; Dash, P.K.; Barooah, B.; Guruprasad, H.P.; Purantharan, N.

    2002-01-01

    Background: Dobutamine Echocardiography and Radionuclide imaging with Tl-201 and Technetium agents are two of the most established techniques available for the detection of viable myocardium. The purpose of this study was to evaluate the utility of Low dose Dobutamine gated Myocardial SPECT in identifying additional areas of dysfunctional, but viable myocardium when compared to nitrate-augmented rest gated SPECT with SestaMIBI. Materials and Methods: 20 patients (19 males and 1 female, with an age range of 40- 65 yrs and a mean of 52.75yrs) all with history of MI or severe LV dysfunction were included in this study. Patients with LBBB, recent revascularisation, arrhythmias etc were excluded from the study. A routine stress-rest study was initially performed on them with 99mTc-SestaMIBI and both the stress as well as resting studies was gated and the resting study was augmented with 10mg of sublingual nitrate. After the resting study was over, the patient was infused with Low dose Dobutamine(5μg/kg/min), at which time the gated acquisition was started and the infusion was continued till the acquisition got completed. In the perfusion study with SestaMIBI, all infarct segments which have uptake less than 50% as compared to the maximally perfused area was deemed non-viable Results: A 17-segment Myocardial model was used for both perfusion as well as quantification of wall motion and wall thickening. 110 akinetic/dyskinetic segments were taken up for analysis. 93 of these segments were non-viable and improvement in wall motion was seen in 17 segments (15.4%) in the nitrate-augmented SPECT. Dobutamine study showed improvement in totally in 27 segments (24.5%), 10 of which were additional segments which were non-viable in Nitrate SPECT study, apart from the 17 segments which showed improvement in the Nitrate study. In Dobutamine study, there was also improvement in wall thickening in 10 (10.7%) out of 93 segments which had showed less than 50% of MIBI uptake. Conclusion

  2. 99mTc labelled cationic lipophilic complexes in malignant and benign tumors: the role of SPET and pinhole-SPET in breast cancer, differentiated thyroid carcinoma and hyperparathyroidism

    International Nuclear Information System (INIS)

    Schillaci, O.; Spanu, A.; Madeddu, G.

    2005-01-01

    Single photon emission tomography (SPET) represents an indispensable diagnostic tool in nuclear medicine. Due to better contrast resolution, cross sectional and 3D images, SPET plays a useful complementary tool to bidimensional planar scintigraphy in certain clinical conditions, while representing the procedure of choice in others. However, high resolution SPET with pinhole collimator (P-SPET) can improve conventional SPET sensitivity with parallel hole collimators. This review summarized data on the employment of conventional SPET and P-SPET in breast cancer, differentiated thyroid cancer (DTC) and hyperparathyroidism patients, using the cationic lipophilic complexes ( 99m Tc )metoxy isobutyl isonitrile (sestaMIBI) and ( 99m Tc )tetrofosmin as oncotropic radiotracers. In breast cancer patients, SPET with these radiotracers can play an important complementary role to planar scintimammography in detecting primary tumors, especially when non palpable and small in size, whereas SPET and particularly P-SPET represents the procedure of choice in preoperative axillary lymph node status evaluation in which planar is almost always irrelevant. In DTC follow-up patients, SPET and P-SPET with cationic lipophilic radiotracers are indicated in both locoregional and distant metastasis detection, especially in patients with high Tg serum levels and negative radioiodine scanning in whom these procedures represent a reliable alternative to diagnostic 131 I scanning. Moreover, the combined use of ( 99m Tc)tetrofosmin P-SPET and US can identify recurrences and lymph node metastases in the neck, both fixing and non fixing iodine, down staged or negative at 131 I scanning. SPET can also be a useful complementary tool to planar parathyroid scintigraphy in the detection and localization of small and ectopic parathyroid adenomas in the neck or mediastinum, while neck P-SPET seems to also significantly increase planer sensitivity in hyperplastic glands. SPET and P-SPET are indicated in

  3. Effects of perfusion detect on the measurement of left ventricular mass, ventricular volume and post-stress left ventricular ejection fraction in gated myocardial perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Byeong Cheol; Bae, Sun Keun; Lee, Sang Woo; Jeong, Sin Young; Lee, Jae Tae; Lee, Kyu Bo [Kyungpook National University Medical School, Daegu (Korea, Republic of)

    2002-12-01

    The presence of perfusion defect may influence the left ventricular mass (LVM) measurement by quantitative gated myocardial perfusion SPECT (QGS), and ischemic myocardium, usually showing perfusion defect may produce post-stress LV dysfunction. This study was aimed to evaluated the effects of extent and reversibility of perfusion defect on the automatic measurement of LVM by QGS and to investigate the effect of reversibility of perfusion defect on post-stress LV dysfunction. Forty-six patients (male/female=34:12, mean age=64 years) with perfusion defect on myocardial perfusion SPECT underwent rest and post-stress QGS. Forty patients (87%) showed reversible defect. End-diastolic volume (EDV), end-systolic volume (ESV), LV ejection fraction (EF), and LV myocardial volume were obtained from QGS by autoquant program, and LVM was calculated by multiplying the LV myocardial volume by the specific gravity of myocardium. LVMs measured at rest and post-stress QGS showed good correlation, and higher correlation was founded in the subjects with fixed perfusion defect and with small defect (smaller than 20%). There were no significant differences in EDVs, ESVs and EFs between obtained by rest and post-stress QGS in patients with fixed myocardial defect. Whereas, EF obtained by post-stress QGS was lower than that by rest QGS in patients with reversible defect and 10 (25%) of them showed decreases in EF more than 5% in post-stress QGS, as compared to that of rest QGS. Excellent correlations of EDVs, ESVs, EFs between rest and post-stress QGS were noted. Patients with fixed defect had higher correlation between defect can affect LVM measurement by QGS and patients with reversible defect shows post-stress LV dysfunction more frequently than patients with fixed perfusion defect.

  4. Stress-induced myocardial ischemia is associated with early post-stress left ventricular mechanical dyssynchrony as assessed by phase analysis of {sup 201}Tl gated SPECT myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Chien-Cheng; Shen, Thau-Yun [Show Chwan Memorial Hospital, Department of Cardiology, Changhua (China); Chang, Ming-Che [Changhua Christian Hospital, Department of Nuclear Medicine, Changhua (China); Hung, Guang-Uei [Chang Bing Show Chwan Memorial Hospital, Department of Nuclear Medicine, Changhua (China); China Medical University, Department of Biomedical Imaging and Radiological Science, Taichung (China); Chen, Wan-Chen [Chang Bing Show Chwan Memorial Hospital, Department of Nuclear Medicine, Changhua (China); Kao, Chia-Hung [China Medical University, Department of Biomedical Imaging and Radiological Science, Taichung (China); Chen, Ji [Emory University School of Medicine, Department of Radiology and Imaging Sciences, Atlanta, GA (United States)

    2012-12-15

    In {sup 201}Tl SPECT myocardial perfusion imaging (MPI) data are acquired shortly after the stress injection to assess early post-stress left ventricle (LV) function. The purpose of this study was to use {sup 201}Tl SPECT MPI to investigate whether stress-induced myocardial ischemia is associated with LV mechanical dyssynchrony. Enrolled in the study were 75 patients who were referred for dipyridamole stress and rest {sup 201}Tl gated SPECT MPI. The early post-stress scan was started 5 min after injection, and followed by the rest scan 4 h later. The patients were divided into three groups: ischemia group (N = 25, summed stress score, SSS, {>=}5, summed rest score, SRS, <5), infarct group (N = 16, SSS {>=}5, SRS {>=}5) and normal group (N = 34, SSS <5, SRS <5). LV dyssynchrony parameters were calculated by phase analysis, and compared between the stress and rest images. In the ischemia group, LV dyssynchrony was significantly larger during stress than during rest. On the contrary, LV dyssynchrony during stress was significantly smaller than during rest in the normal and infarct groups. LV dyssynchrony during rest was significantly larger in the infarct group than in the normal and ischemia groups. There were no significant differences in LV dyssynchrony during rest between the normal and ischemia groups. Stress-induced myocardial ischemia caused dyssynchronous contraction in the ischemic region, leading to a deterioration in LV synchrony. Normal myocardium had more synchronous contraction during stress. The different dyssynchrony pattern between ischemic and normal myocardium early post-stress may aid the diagnosis of coronary artery disease using {sup 201}Tl gated SPECT MPI. (orig.)

  5. Acute myocardial infarction due to spontaneous, localized, acute dissection of the sinus of Valsalva detected by intravascular ultrasound and electrocardiogram-gated computed tomography.

    Science.gov (United States)

    Ichihashi, Taku; Ito, Tsuyoshi; Murai, Shunsuke; Ikehara, Noriyuki; Fujita, Hiroshi; Suda, Hisao; Ohte, Nobuyuki

    2016-09-01

    A 58-year-old man was referred to our hospital because of chest pain. The 12-lead electrocardiogram (ECG) revealed ST-segment elevation in II, III, and a Vf with advanced heart block. Transthoracic echocardiography demonstrated aortic root dilatation at the sinus of Valsalva, moderate aortic regurgitation, and decreased wall motion in the inferior part of the left ventricle. Non-ECG-gated enhanced computed tomography (CT) did not reveal an aortic dissection. The patient underwent emergent coronary angiography, which revealed a severely narrowed ostium of the right coronary artery (RCA). Percutaneous coronary intervention (PCI) was performed under intravascular ultrasound (IVUS) guidance. IVUS images demonstrated an intimal flap extending from the aortic wall to the proximal RCA, suggesting that a periaortic hematoma in the false lumen compressed the ostium of the RCA, leading to acute myocardial infarction. To recover hemodynamic stability, the RCA ostium was stented. Subsequent ECG-gated enhanced CT clearly depicted the entry point and extension of the dissection localized within the sinus of Valsalva. The dissection likely involved the left main coronary artery and an emergent Bentall procedure was performed. Intraoperative findings confirmed an intimal tear and extension of the dissection. Thus, ECG-gated CT can clearly depict the entry site and extension of a dissection occurring in the localized area that cannot be detected by conventional CT.

  6. Quantitative evaluation of renal dynamic scan with 99mTc-MAG3 assessment of interoposterior myocardial infarction using ECG gated SPECT with 99mTc-MIBI

    International Nuclear Information System (INIS)

    Cho, Keiichi; Kumita, Shinichiro; Mizumura, Sunao

    1997-01-01

    Simultaneous assessment of regional myocardial perfusion and local contraction ability of interoposterior myocardial infarction was examined by ECG gated SPECT. In thirteen cases of acute interoposterior myocardial infarction, the above-mentioned data were obtained by 180deg data acquisition method using L-shaped 2 detecting element type gamma camera. Mean and standard deviation of %Uptake and wall thickening (WT) in inferior wall were as follows: Infarction case; 57±9.2%/23±11.3%, normal case; 71±8.2%/61±10.2%. The significant depression (p<0.01/p<0.001) of both data were found in the infarction case. The both data in posterior wall were as follows: Infarction case; 55±10.7%/16±8.9%, normal case; 64±9.7%/41±15.0%. The significant depression (p<0.05/p<0.001) were also found in the infarction case. In both inferior wall and posterior wall, the AUC of ROC curve of WT was greater than that of %Uptake, and diagnostic ability of this method was favorable. The best sensitivity/specificity rate and the threshold were as follows: %Uptake of inferior wall 77/65, -0.5SD, WT of inferior wall 100/100, -2SD, %Uptake of posterior wall 62/82, -1SD, WT of posterior wall 85/88, -4SD. Accordingly, in diagnosis of interoposterior myocardial infarction, assessment of focus cardiac function, for example WT, is necessary as well as %Uptake. (K.H.)

  7. 2D-STI combined with gated 99Tcm-MIBI MPI for the diagnosis of myocardial ischemia in hypercholesterolemia patients.

    Science.gov (United States)

    Song, Yi; Zhang, Rui-Fang; Liu, Yu

    2017-08-01

    This study aimed to investigate the reliability of ultrasound two-dimensional speckle tracking imaging (2D-STI) for the evaluation of myocardial ischemia in familial hypercholesterolemia (FH) patients. We recruited 28 patients clinically diagnosed with homozygous familial hypercholesterolemia (HoFH) and subjected them to 2D-STI, gated transthoracic Doppler echocardiography (TTDE), and 99 Tc m -methoxyisobutylisonitrile myocardial perfusion imaging ( 99 Tc m -MIBI MPI). The sensitivity, specificity and diagnostic accordance rate of TTDE and 2D-STI for myocardial ischemia in HoFH patients were compared with the 99 Tc m -MIBI scores. According to the diagnosis of ischemia in the three main coronary arteries (LAD, LCX, and RCA) by MPI, patients were further divided into different groups for comparing segmental strain by 2D-STI. The total correlation between TTDE and 99 Tc m -MIBI MPI for evaluation of myocardial ischemia was r=0.483 and between 2D-STI and 99 Tc m -MIBI MPI was 0.786. The total correlation index for ejection fraction (EF) between TTDE and 99 Tc m -MIBI MPI was r=0.606 and for 2D-STI and 99 Tc m -MIBI MPI was r=0.919. TTDE indicated that differences among LVDd, LVDs, IVS, LVPW, AO Vmax, PG, E/e', and DT were statistically significant. STI indicated that the total strain of the ischemia group was lower than that of the non-ischemia group. The total systolic strain and total early diastolic strain of the ischemia group were lower than that of the non-ischemia group. TTDE can be used for primary observation and evaluation of ventricular wall ischemia for HoFH patients. Ultrasound 2D-STI is better than TTDE in the evaluation of myocardial ischemia in HoFH patients. Ultrasound 2D-STI shows the same effectiveness as 99 Tc m -MIBI MPI for the detection of myocardial ischemia, serving as good tool for prognosis and treatment evaluation in HoFH patients.

  8. Tc-99m ECD brain SPET in the evaluation of dementia for institutionalized elderly patients

    International Nuclear Information System (INIS)

    Lee, Myoung Hoon; Park, Chan H.; Yoon, Seok Na.; Hwang, Kyung Hoon

    2001-01-01

    Dementia is one of the clinically recognized indications of regional cerebral blood flow (rCBF) measurement by Tc-99m ECD brain SPET (Single Photon Emission Tomography). There is only limited number of institutions for elderly demented patients who are institutionalized in Korea and SPET is nor available at these institutions. The aim of the study is to evaluate rCBF SPET findings of the patients from such an institution. Thirty-one patients were reffered for rCBF SPET from Yongin Hyoja Hospital, Yongin. They were screened using NINCDS-ADRDA criteria for probable Alzheimers disease (AD) and dementia severity was assumed by the Mini-Mental State examination. In a quite, dim light room, patients were injected with 740 mBq (20mCi) Tc-99m ethyl cysteinate dimmer (ECD), Neurolite R, Dupont Pharmaceuticals, Billerica, MA, USA). SPET was acquired using fanbeam collimators and triple-head gamma camera (MultiSPECT III, Siemens medical systems. Inc. Hoffman Estates, III.USA). SPET was done one hour after the tracer injection and most of the patients needed sedation 30 minutes before the scan. SPET was evaluated visually by 2 nuclear medicine physicians blinded to clinical information. The SPET scans of 31 patients revealed 3 typical AD, 9 atypical AD patterns. Other dementia patterns were 4 cases of frontotemporal lobe dementia, 5 cases of frontal lobe dementia and 2 multifocal infarctions. Only cerebral atrophy is depicted in 8 patients and normal SPECT findings was noted in one patient. Patients who are institutionalized for dementia have varying SPET patterns as expected and SPET findings are useful in the management of these patients with more clearer clinical insight

  9. Optimisation of brain SPET and portability of normal databases.

    Science.gov (United States)

    Barnden, Leighton R; Hatton, Rochelle L; Behin-Ain, Setayesh; Hutton, Brian F; Goble, Elizabeth A

    2004-03-01

    Use of a normal database in quantitative regional analysis of brain single-photon emission tomography (SPET) facilitates the detection of functional defects in individual or group studies by accounting for inter-subject variability. Different reconstruction methods and suboptimal attenuation and scatter correction methods can introduce additional variance that will adversely affect such analysis. Similarly, processing differences across different instruments and/or institutions may invalidate the use of external normal databases. The object of this study was to minimise additional variance by comparing reconstructions of a physical phantom with its numerical template so as to optimise processing parameters. Age- and gender-matched normal scans acquired on two different systems were compared using SPM99 after processing with both standard and optimised parameters. For three SPET systems we have optimised parameters for attenuation correction, lower window scatter subtraction, reconstructed pixel size and fanbeam focal length for both filtered back-projection (FBP) and iterative (OSEM) reconstruction. Both attenuation and scatter correction improved accuracy for all systems. For single-iteration Chang attenuation correction the optimum attenuation coefficient (mu) was 0.45-0.85 of the narrow beam value (Nmu) before, and 0.75-0.85 Nmu after, scatter subtraction. For accurately modelled OSEM attenuation correction, optimum mu was 0.6-0.9 Nmu before and 0.9-1.1 Nmu after scatter subtraction. FBP appeared to change in-plane voxel dimensions by about 2% and this was confirmed by line phantom measurements. Improvement in accuracy with scatter subtraction was most marked for the highest spatial resolution system. Optimised processing reduced but did not remove highly significant regional differences between normal databases acquired on two different SPET systems.

  10. Incremental prognostic value of cardiac function assessed by ECG-gated myocardial perfusion SPECT for the prediction of future acute coronary syndrome

    International Nuclear Information System (INIS)

    Matsumoto, Naoya; Sato, Yuichi; Suzuki, Yasuyuki

    2008-01-01

    The prognostic value of electrocardiogram (ECG)-gated rest 201 T1/stress 99m Tc-tetrofosmin myocardial perfusion single-photon emission computed tomography for the prediction of acute coronary syndrome (ACS: myocardial infarction (MI) and unstable angina (UA)) and the implications of ejection fraction (EF) has not yet been defined in Japanese. The 1,895 patients were followed up for the occurrence ACS. The mean follow-up interval was 26.9±15.5 months. The 142 patients with revascularization within 60 days were censored. Summed stress score (SSS) and summed difference score (SDS) were calculated. The 19 MI and 29 UA occurred (1.1% and 1.6%, respectively). Univariate Cox analysis showed that hypertension (Wald 5.09, p<0.05), poststress EF (Wald 10.9, p<0.01), SSS (Wald 12.4, p<0.001) and SDS (Wald 18.7, p<0.001) were significant predictors of ACS. Multivariate Cox analysis showed that hypertension (Wald 4.27, p<0.05) and SDS (Wald 8.59, p<0.01) were independent predictors. When multiple clinical risk factors (number of coronary risk factors ≥2), significant ischemia (SDS≥4) and low EF (EF<45%) were applied to multivariate Cox analysis, the combination of significant ischemia and low EF showed the highest predictive value (Wald 11.9; p<0.001) for future ACS. Poststress EF added incremental prognostic value for the prediction of ACS. (author)

  11. Assessment of Heart Rate Recovery with GATED-Myocardial Perfusion Scintigraphy Outcome in Patients with Coronary Artery Disease: A Retrospective Study and Institutional Experience

    Directory of Open Access Journals (Sweden)

    Yusuf Ziya Tan

    2016-10-01

    Full Text Available Objective: This study aimed to investigate the effects of assessment with myocardial perfusion scintigraphy (MPS and heart rate recovery (HRrec measurements in combination to evaluate the current status of patients with a diagnosis or suspicion of coronary artery disease (CAD. Methods: A total of 350 patients were included in the study. CAD group consisted of 200 patients with stable angina pectoris and a known history of CAD, while the control group consisted of 150 patients with suspicious stress test who had no history of known CAD. In order to calculate the HRrec index, the treadmill exercise test was performed in all patients according to the Bruce protocol. The MPS results were evaluated for the presence or absence of myocardial ischemia and infarction by visual and quantitative (summed stress score and summed difference score assessments. 
 Results: When the MPS results and HRrec were evaluated together, there was no statistically significant difference in the non-CAD group. But, when GATED-MPS was evaluated alone in the triple-vessel patient group, 27 (36% patients were found to be normal while evaluated with HRrec, four (5.3% patients were found to be normal. Conclusion: HRrec measurements obtained during stress MPS is important in patient evaluation. Therefore, evaluation of MPS results and HRrec measurements together may provide a more accurate estimation of possible presence of CAD in patients.

  12. Comparison of phase dyssynchrony analysis using gated myocardial perfusion imaging with four software programs: Based on the Japanese Society of Nuclear Medicine working group normal database.

    Science.gov (United States)

    Nakajima, Kenichi; Okuda, Koichi; Matsuo, Shinro; Kiso, Keisuke; Kinuya, Seigo; Garcia, Ernest V

    2017-04-01

    Left ventricular (LV) phase dyssynchrony parameters based on gated myocardial perfusion imaging varied among software programs. The aim of this study was to determine normal ranges and factors affecting phase parameters. Normal databases were derived from the Japanese Society of Nuclear Medicine working group (n = 69). The programs were Emory Cardiac Toolbox with SyncTool (ECTb), Quantitative Gated SPECT (QGS), Heart Function View (HFV), and cardioREPO (cREPO); parameters of phase standard deviation (PSD), 95% bandwidth, and entropy were compared with parameters with ECTb as a reference. PSD (degree) was 5.3 ± 3.3 for QGS (P < .0001), 5.4 ± 2.5 for HFV (P < .0001), and 10.3 ± 3.2 for cREPO (P = n. s.) compared with 11.5 ± 5.5 for ECTb. Phase bandwidth with three programs differed significantly from ECTb. Gender differences were significant for all programs, indicating larger variation in males. After adjustment of LV volumes between genders, the difference disappeared except for QGS. The phase parameters showed wider variations in patients with the lower ejection fraction (EF) and larger LV volumes, depending on software types. Based on normal ranges of phase dyssynchrony parameters in four software programs, dependency on genders, LV volume, and EF should be considered, indicating the need for careful comparison among different software programs.

  13. Combined assessment of myocardial perfusion and function by ECG-gated myocardial perfusion single-photon emission computed tomography for the prediction of future cardiac events in patients with type 2 diabetes mellitus

    International Nuclear Information System (INIS)

    Kato, Masahiko; Matsumoto, Naoya; Nakano, Yoshimochi; Suzuki, Yasuyuki; Yoda, Shunichi; Nagao, Ken; Hirayama, Atsushi; Sato, Yuichi; Kasama, Shu

    2011-01-01

    The mid-term prognostic significance of electrocardiogram (ECG)-gated single-photon emission computed tomography (SPECT) remains unclear in Japanese patients with type 2 diabetes mellitus (DM). In the present study rates of future cardiac events (nonfatal acute myocardial infarction (AMI), cardiac death (CD) and severe heart failure (HF) requiring hospitalization) were compared in patients with and without DM. 1,810 patients (563 DM and 1,247 non-DM) we followed for a mean of 26.3±15.5 months. Summed stress score (SSS), summed difference score (SDS), poststress ejection fraction (EF) and resting end-diastolic volume (EDV) were calculated. In total, 20 cases of AMI (9 in DM (1.59%) and 11 in non-DM (0.88%)), 20 of CD (7 in DM patients (1.24%) and 13 in non-DM (1.04%)) and 54 of severe HF (31 in DM (5.5%) and 23 in non-DM (1.84%)) occurred. Univariate Cox analysis showed that, in DM patients, predictors of total cardiac events were poststress EF (Wald 60.4; P 1c value (Wald 4.30; P<0.05). Multivariate Cox analysis showed that poststress EF (Wald 9.85; P<0.01) and SDS (Wald 6.19; P<0.01) were independent predictors of total cardiac events. Combined assessment of perfusion and function by ECG-gated SPECT may predict future cardiac events in type 2 DM patients. (author)

  14. Comparative myocardial uptake of technetium-99 m sestamibi and technetium-99m tetrofosmin one hour after stress injection

    International Nuclear Information System (INIS)

    Gremillet, E.; Champailler, A.

    1998-01-01

    Technetium-99m sestamibi and 99m Tc-tetrofosmin are at present the preferred tracers for simultaneous assessment of myocardial perfusion and function by gated single-photon emission tomography (SPET). The aim of this work was to compare sestamibi and tetrofosmin myocardial uptake 1 h after stress injection. Consecutive unselected patients were studied either with sestamibi or with tetrofosmin on a random basis, until at least 100 patients had been enrolled for each gender and tracer. Stress was obtained by dipyridamole or exercise or combined dipyridamole + exercise; in the latter cases, exercise was sustained for at least 1.5 min after tracer injection. Injected activity was similarly adjusted to body weight. For each patient, imaging began 60-75 min after injection. All SPET projections were summed; due to the acquisition technology (''roving zoom'', i.e. a mobile zoom), the heart always appeared at the centre of the frame in all projections and in the sum image. Thus minimal lung background contamination could be assumed in an elliptic region of interest placed over the heart on the sum image. Three indexes were analysed: total myocardial counts (Sum), mean myocardial pixel (Mean) and maximum myocardial pixel (Max). Four patient groups were analysed: males with sestamibi or tetrofosmin (MS: n = 189 and MT: n = 157), females with sestamibi or tetrofosmin (FS: n = 101 and FT: n = 104). MS and MT groups were comparable for physical variables, maximum heart rate and stress type, as were the FS and FT groups. Sum, Mean and Max were significantly higher with sestamibi (P = 0.0001 by ANOVA). Comparing MS vs MT and FS vs FT, mean values ± SD were as follows: for Sum (kcounts) 750±184 vs 652±166, and 707±202 vs 594±189; for Mean (counts) 4517±1171 vs 4107±898, and 4908±1119 vs 4144±1025; and for Max (counts) 6471±1654 vs 5794±1312, and 7318±1886 vs 6152±1684. The mean gain with sestamibi was +15%, +10% and +12% in males, and +19%, +18% and +19% in females

  15. Comparison of two-dimensional echocardiography with gated radionuclide ventriculography in the evaluation of global and regional left ventricular function in acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Van Reet, R.E.; Quinones, M.A.; Poliner, L.R.; Nelson, J.G.; Waggoner, A.D.; Kanon, D.; Lubetkin, S.J.; Pratt, C.M.; Winters, W.L. Jr.

    1984-02-01

    Two-dimensional echocardiography and gated radionuclide ventriculography were performed in 93 patients (66 men, 27 women; mean age 61 years) with 95 episodes of acute myocardial infarction within 48 hours and at 10 days after infarction. Abnormal motion of an inferior or posterior wall segment was seen in 91% of inferoposterior infarctions by echocardiography versus 61% seen by radionuclide ventriculography. Ejection fractions determined by echocardiography and radionuclide ventriculography correlated well (r . 0.82) and did not change from the first 48 hours to 10 days after infarction (0.48 +/- 0.14). Similarly, wall motion score showed minimal change from the first 48 hours to 10 days. In-hospital mortality was 37 and 42% in patients with an ejection fraction of 0.35 or less by echocardiography and radionuclide ventriculography, respectively. No mortality was seen in patients with an ejection fraction above 0.40 by either test. The echocardiographic wall motion score was also predictive of mortality (40 versus 2%; score less than or equal to 0.50 versus greater than 0.50). The 1 year mortality rate in the 81 short-term survivors was 17%. Mortality was lowest in patients with an ejection fraction above 0.49 or wall motion score above (0.79 (2 to 5%) and worse in those with an ejection fraction below 0.36 or wall motion score below 0.51 (36 to 63%) by either technique. Thus in acute myocardial infarction, echocardiography and radionuclide ventriculography provide a comparable assessment of left ventricular function and wall motion in anterior infarction. Echocardiography appears more sensitive in detecting inferoposterior wall motion abnormalities. Both techniques are capable of identifying subgroups of patients with a high risk of death during the acute event and with an equally high mortality rate over a 1 year follow-up period.

  16. SPET with 99mTc-HM PAO in the study of classic migraine

    International Nuclear Information System (INIS)

    Stiglich, F.; Bonomo, F.; Barbonetti, C.; Di Lorenzo, I.; Bottinelli, G.; Tomaiolo, S.; Campani, R.; Bottinelli, O.

    1991-01-01

    Five patients presenting with migraine attacks underwent Electroencephalography (EEC), Computed Tomography (CT) and Single Photon Emission Tomography (SPET) with 99m Tc-HM PAO. EEG qand SPET were subsequently repeated in the intercritical period. We observed that two patients only showed non-specific abnormalities in EEG; scans were in all patients; all subjects exhibited diffuse cortical hypoperfusion. A strong correlation was always found between clinical presentation and hemispheric impairment. One patient exhibited asymmetrical perfusion between cerebellum hemispheres; intercritical SPET showed homogeneous distrubution of the radio-tracer in 4 patients. In the last one minimal residual hypoperfusion was observed, although less marked than in the acute phase. Therefore SPET with 99m Tc-HM PAO can be reasonably employed as the examination of choice when a migrain attack is clinically suspected, because of its reproducibility and reliability. It can be easily performed in every nuclear medical center supplied with modern tomographic cameras

  17. Application of statistical parametric mapping to SPET in the assessment of intractable childhood epilepsy

    International Nuclear Information System (INIS)

    Bruggemann, Jason M.; Lawson, John A.; Cunningham, Anne M.; Som, Seu S.; Haindl, Walter; Bye, Ann M.E.

    2004-01-01

    Statistical parametric mapping (SPM) quantification and analysis has been successfully applied to functional imaging studies of partial epilepsy syndromes in adults. The present study evaluated whether localisation of the epileptogenic zone (determined by SPM) improves upon visually examined single-photon emission tomography (SPET) imaging in presurgical assessment of children with temporal lobe epilepsy (TLE) and frontal lobe epilepsy (FLE). The patient sample consisted of 24 children (15 males) aged 2.1-17.8 years (9.8±4.3 years; mean±SD) with intractable TLE or FLE. SPET imaging was acquired routinely in presurgical evaluation. All patient images were transformed into the standard stereotactic space of the adult SPM SPET template prior to SPM statistical analysis. Individual patient images were contrasted with an adult control group of 22 healthy adult females. Resultant statistical parametric maps were rendered over the SPM canonical magnetic resonance imaging (MRI). Two corresponding sets of ictal and interictal SPM and SPET images were then generated for each patient. Experienced clinicians independently reviewed the image sets, blinded to clinical details. Concordance of the reports between SPM and SPET images, syndrome classification and MRI abnormality was studied. A fair level of inter-rater reliability (kappa=0.73) was evident for SPM localisation. SPM was concordant with SPET in 71% of all patients, the majority of the discordance being from the FLE group. SPM and SPET localisation were concordant with epilepsy syndrome in 80% of the TLE cases. Concordant localisation to syndrome was worse for both SPM (33%) and SPET (44%) in the FLE group. Data from a small sample of patients with varied focal structural pathologies suggested that SPM performed poorly relative to SPET in these cases. Concordance of SPM and SPET with syndrome was lower in patients younger than 6 years than in those aged 6 years and above. SPM is effective in localising the potential

  18. Technetium-99m sestamibi single-photon emission tomography detects subclinical myocardial perfusion abnormalities in patients with systemic lupus erythematosus

    International Nuclear Information System (INIS)

    Schillaci, O.; Lagana, B.; Gentile, R.; Tubani, L.; Baratta, L.; Danieli, R.; Scopinaro, F.

    1999-01-01

    In patients with systemic lupus erythematosus, involvement of the cardiovascular system is the third leading cause of death. However, although autopsy studies have demonstrated a high incidence of abnormalities in both the myocardium and coronary vessels, clinical manifestations have been reported in only a small percentage of cases. The aim of this study was to evaluate myocardial perfusion in asymptomatic lupus patients using technetium-99m sestamibi single-photon emission tomography (SPET). Twenty-eight patients without overt cardiac involvement and risk factors were studied with 99m Tc-sestamibi SPET at rest and after dipyridamole infusion. Perfusion abnormalities were detected in 18 cases: six had persistent defects, three had reversible defects, seven had both persistent and reversible defects, and two showed rest defects which normalized on dipyridamole images (''reverse redistribution pattern''). Coronary angiography was performed in eight patients with positive 99m Tc-sestamibi SPET, and showed normal epicardial vessels in all the cases. These results indicate that 99m Tc-sestamibi SPET reveals a high prevalence (18 out of 28 patients in this study, i.e. 64%) of myocardial perfusion abnormalities in asymptomatic lupus patients, probably due to the primary immunological damage of this autoimmune disease. In conclusion, rest/dipyridamole 99m Tc-sestamibi SPET can be a useful non-invasive method to identify subclinical myocardial involvement in systemic lupus erythematosus, and patients potentially at risk of later cardiac events. (orig.)

  19. Technetium-99m sestamibi single-photon emission tomography detects subclinical myocardial perfusion abnormalities in patients with systemic lupus erythematosus

    Energy Technology Data Exchange (ETDEWEB)

    Schillaci, O. [Nuclear Medicine, University of l`Aquila (Italy); Lagana, B.; Gentile, R.; Tubani, L.; Baratta, L. [Department of Clinical Medicine, University ``La Sapienza``, Rome (Italy); Danieli, R.; Scopinaro, F. [Section of Nuclear Medicine, Department of Experimental Medicine and Pathology, University ``La Sapienza``, Rome (Italy)

    1999-07-01

    In patients with systemic lupus erythematosus, involvement of the cardiovascular system is the third leading cause of death. However, although autopsy studies have demonstrated a high incidence of abnormalities in both the myocardium and coronary vessels, clinical manifestations have been reported in only a small percentage of cases. The aim of this study was to evaluate myocardial perfusion in asymptomatic lupus patients using technetium-99m sestamibi single-photon emission tomography (SPET). Twenty-eight patients without overt cardiac involvement and risk factors were studied with {sup 99m}Tc-sestamibi SPET at rest and after dipyridamole infusion. Perfusion abnormalities were detected in 18 cases: six had persistent defects, three had reversible defects, seven had both persistent and reversible defects, and two showed rest defects which normalized on dipyridamole images (``reverse redistribution pattern``). Coronary angiography was performed in eight patients with positive {sup 99m}Tc-sestamibi SPET, and showed normal epicardial vessels in all the cases. These results indicate that {sup 99m}Tc-sestamibi SPET reveals a high prevalence (18 out of 28 patients in this study, i.e. 64%) of myocardial perfusion abnormalities in asymptomatic lupus patients, probably due to the primary immunological damage of this autoimmune disease. In conclusion, rest/dipyridamole {sup 99m}Tc-sestamibi SPET can be a useful non-invasive method to identify subclinical myocardial involvement in systemic lupus erythematosus, and patients potentially at risk of later cardiac events. (orig.) With 2 figs., 2 tabs., 21 refs.

  20. The relationship between coronary artery calcification detected by non-gated multi-detector CT in patients with suspected ischemic heart disease and myocardial ischemia detected by thallium exercise stress testing.

    Science.gov (United States)

    Nishida, Chikako; Okajima, Kaoru; Kudo, Takashi; Yamamoto, Takashi; Hattori, Ryuichi; Nishimura, Yasumasa

    2005-12-01

    To examine whether we could predict myocardial ischemia when coronary artery calcification is detected by non-gated multidetector CT in patients with suspected ischemic heart disease. Eighty-three patients suspected of having ischemic heart disease (55 men, 28 women; age range 36-83 years; mean age 68 years) underwent multidetector CT and T1-201 single photon emission computed tomography. Prediction of myocardial ischemia by coronary arterial calcification detected on CT was evaluated by comparing the coronary artery territories that showed calcification with the area of myocardial ischemia determined by SPECT. The sensitivity, specificity, positive predictive value, and negative predictive value of multidetector CT for predicting myocardial ischemia were calculated. Coronary angiography was also examined and compared with multidetector CT. Risk factors, including hypertension, smoking, hyperlipidemia, diabetes, and family history, were compared for evidence of coronary artery calcification detected by multidetector CT and myocardial ischemia detected by thallium nuclear scans. For analysis by patients, the sensitivity, specificity, positive predictive value, and negative predictive value of coronary artery calcification for myocardial ischemia detection were 65, 63, 56, and 71%, respectively. Similarly, for analysis by coronary arterial territories, those values were 56, 77, 41 and 86%, respectively. Coronary stenosis on CAG was also related to the ischemia determined by SPECT and calcification on multidetector CT. Ischemia was better influenced by risk factors than was coronary arterial calcification. For analysis by coronary arterial territories, the specificity and negative predictive value of coronary arterial calcification seen by multidetector CT are relatively high.

  1. Asymmetrically thickened posterior wall is associated with decline of ejection fraction after stress on adenosine stress/rest thallium-201 gated myocardial SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bom Sahn; Lee, Won Woo; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul; Kim, Sang Eun [College of Medicine, Seoul National University, Seoul (Korea, Republic of)

    2004-07-01

    LV parameters (LVEF. ESVI and EDVI) on adenosine stress/rest thallium-201 gated myocardial SPECT (gSPECT) are various from stress to rest. We investigated the reason why they were various in patients without coronary artery disease. Seventy-one patients(M:F=32:39, age 58.1{+-}9.7yrs), who underwent gSPECT and coronary angiography (CAG) due to chest pain or preoperative evaluation were included. CAG results were normal or insignificant. Exclusion criteria were atrial fibrillation, thyroid disease, primary cardiomyopathy, myocardial bridge, LBBB, MI, and valvular heart disease. Patients were calssified into 3 groups by EF difference ({delta}EF=rest-stress EF) on gSPECT : group1 ({delta}EF{>=}10), group2 (0 {<=}{delta}EF<10), and group3 ({delta}EF<0). LV parameters on gSPECT and thicknesses of IVS (interventricular septum) and LVPW (left ventricular posterior wall) on echocardiography were compared among the 3 groups. Myocardial perfusion status were normal or mild reversible/persistent perfusion defect in 76.1% (54/71). LVEFs at stress were not different among all 3 groups : 59.3{+-}8.54% in group 1 (61.3{+-}10.22% in group 2 and 64.8{+-}7.58% in group 3 (p>0.05). But LVEF at rest was smaller in group 3 (58.7{+-}8.38%) than the other groups (72.5{+-}8.77% in group1 and 66.7{+-}10.6% in group2) (p<0.01). EDVIs and ESVI at stress were larger than those at rest in all groups (p<0.05) except ESVI in group 3 (16.2{+-}6.21ml at stress and 17.5{+-}6.41ml at rest, p<0.01), and that was attributed to EF<0 in group 3. In echocardiographical analysis, group 3 had significantly increased wall thickness of LVPW (10.7{+-}1.2mm versus 9.4{+-}1.6mm, p=0.01) and decreased wall thickness ratio of IVS/LVPW (0.963{+-}0.102 versus 1.048{+-}0.104, p=0.035) than group 1. In patients without coronary artery disease, LVEF, EDVI and ESVI on gSPECT were various and decline of LVEF from stress to rest was caused by unnormalized ESVI . Asymmetrically thickened LVPW may play a crucial role and

  2. Exercise-induced stunning continues for at least one hour: evaluation with quantitative gated single-photon emission tomography

    International Nuclear Information System (INIS)

    Paul, A.K.; Hasegawa, Shinji; Yoshioka, Jun; Tsujimura, Eiichiro; Yamaguchi, Hitoshi; Tokita, Naoki; Maruyama, Atsushi; Xiuli, Mu; Nishimura, Tsunehiko

    1999-01-01

    To elucidate the after-effect of exercise on left ventricular (LV) function, end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (LVEF) were evaluated at 1 h after exercise and at rest by technetium-99m tetrofosmin gated myocardial single-photon emission tomography (SPET) using an automated program in 53 subjects. The subjects were grouped as follows: normal scan (n = 16), ischaemia (n = 19) and infarction (n = 18), based on the interpretation of perfusion images. Postexercise LVEF did not differ from resting LVEF in the groups with normal scan and infarction. In patients with ischaemia, postexercise EDV (90±17 ml, mean ±SD) and ESV (44±15 ml) were significantly higher than EDV (84±15 ml, P = 0.001) and ESV (36±14 ml, P<0.0005) at rest. LVEF was significantly depressed 1 h after exercise (53%±9% vs 58%±9%, P<0.0001). In ischaemic patients with depressed postexercise LVEF, LVEF difference between rest and postexercise showed a significant correlation with the sum of defect scores, which were reversible from exercise to rest perfusion images (r = 0.92, P<0.0001). These results indicate that exercise-induced LV dysfunction (myocardial stunning) continues for at least 1 h in ischaemic patients and that the extent of LVEF depression is determined by the severity of ischaemia. (orig.)

  3. Exercise-induced stunning continues for at least one hour: evaluation with quantitative gated single-photon emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Paul, A.K.; Hasegawa, Shinji; Yoshioka, Jun; Tsujimura, Eiichiro; Yamaguchi, Hitoshi; Tokita, Naoki; Maruyama, Atsushi; Xiuli, Mu; Nishimura, Tsunehiko [Division of Tracer Kinetics, Biomedical Research Center, Osaka University Medical School, Suita, Osaka (Japan)

    1999-04-29

    To elucidate the after-effect of exercise on left ventricular (LV) function, end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (LVEF) were evaluated at 1 h after exercise and at rest by technetium-99m tetrofosmin gated myocardial single-photon emission tomography (SPET) using an automated program in 53 subjects. The subjects were grouped as follows: normal scan (n = 16), ischaemia (n = 19) and infarction (n = 18), based on the interpretation of perfusion images. Postexercise LVEF did not differ from resting LVEF in the groups with normal scan and infarction. In patients with ischaemia, postexercise EDV (90{+-}17 ml, mean {+-}SD) and ESV (44{+-}15 ml) were significantly higher than EDV (84{+-}15 ml, P = 0.001) and ESV (36{+-}14 ml, P<0.0005) at rest. LVEF was significantly depressed 1 h after exercise (53%{+-}9% vs 58%{+-}9%, P<0.0001). In ischaemic patients with depressed postexercise LVEF, LVEF difference between rest and postexercise showed a significant correlation with the sum of defect scores, which were reversible from exercise to rest perfusion images (r = 0.92, P<0.0001). These results indicate that exercise-induced LV dysfunction (myocardial stunning) continues for at least 1 h in ischaemic patients and that the extent of LVEF depression is determined by the severity of ischaemia. (orig.) With 7 figs., 19 refs.

  4. Reversible wall motion abnormality on adenosine stress/rest thallium-201 gated myocardial SPECT is an independent predictor of coronary artery disease

    International Nuclear Information System (INIS)

    Park, Eun Kyung; Lee, Won Woo; So, Young; Eo, Jae Seon; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul; Kim, Sang Eun; Kim, Cheol Ho; Lee, Sang Woo

    2004-01-01

    As early as 10 minutes after adenosine stress, immediate post-stress wall motion (ipsWM) can be evaluated on adenosine stress/rest TI-201 gated SPECT (gSPECT). To widen application of TI-201 in gated SPECT, we investigated image quality, LV parameters (EF, EDV, and ESV) reproducibility, and diagnostic competency of gSPECT regarding ipsWM evaluation Myocardial perfusion and wall motion were evaluated by 5-point scoring system in 20-segment model. Image quality was assessed using weighted Kappa (Kw) for inter-and intra-observer agreements of wall motion scores (n=49). Reproducibility was examined through repeated acquisition (n=31). Diagnostic competency was evaluated versus coronary angiography (CAG) and multivariate logistic regression analysis was performed to identify significant predictors of coronary artery disease (CAD) among stress abnormal perfusion (SSSp), stress abnormal wall motion (SSSwm), and reversible abnormal wall motion (SDSwm) (n=60). Kw for ipsWM was significantly better than that for rest regarding inter- (0.717 vs 0.489) and intra-observer agreements (0.792 vs 0.688) (p<0.05). 2SD for ipsWM was smaller than that for rest at EF (8.6% vs 10.7%) and ESV (6.0ml vs 8.4ml). Sensitivities of SSSp, SSSwm, and SDSwm were 63.3% (19/30), 63.3% (19/30), and 43.3% (13/30) and specificities 83.3% (25/30), 83.3% (25/30), and 86.7% (26/30), respectively. By multivariate analysis, SSSp (p=0.013) and SDSwm (p=0.039) remained significant predictors. Additionally, SSSwm or SDSwm could find undetected CAD in 54.5% (6/11) of patients with normal perfusion. TI-201 can be successfully applied to gated SPECT for ipsWM evaluation. Moreover, reversible wall motion abnormality on gSPECT is an independent predictor of significant CAD

  5. Evaluation of left ventricular function and volumes in patients with ischaemic cardiomyopathy: gated single-photon emission computed tomography versus two-dimensional echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Vourvouri, E.C.; Poldermans, D.; Sianos, G.; Sozzi, F.B.; Schinkel, A.F.L.; Sutter, J. de; Roelandt, J.R.T.C. [Dept. of Cardiology, Erasmus Medical Center Rotterdam (Netherlands); Bax, J.J. [Dept. of Cardiology, Leiden Univ. Medical Center (Netherlands); Parcharidis, G. [Dept. of Cardiology, AHEPA Univ. Hospital, Thessaloniki (Greece); Valkema, R. [Dept. of Nuclear Medicine, Erasmus Medical Center Rotterdam (Netherlands)

    2001-11-01

    The objective of this study was to perform a head-to-head comparison between two-dimensional (2D) echocardiography and gated single-photon emission computed tomography (SPET) for the evaluation of left ventricular (LV) function and volumes in patients with severe ischaemic LV dysfunction. Thirty-two patients with chronic ischaemic LV dysfunction [mean LV ejection fraction (EF) 25%{+-}6%] were studied with gated SPET and 2D echocardiography. Regional wall motion was evaluated by both modalities and scored by two independent observers using a 16-segment model with a 5-point scoring system (1= normokinesia, 2= mild hypokinesia, 3= severe hypokinesia, 4= akinesia and 5= dyskinesia). LVEF and LV end-diastolic and end-systolic volumes were evaluated by 2D echocardiography using the Simpson's biplane discs method. The same parameters were calculated using quantitative gated SPET software (QGS, Cedars-Sinai Medical Center). The overall agreement between the two imaging modalities for assessment of regional wall motion was 69%. The correlations between gated SPET and 2D echocardiography for the assessment of end-diastolic and end-systolic volumes were excellent (r=0.94, P<0.01, and r=0.96, P<0.01, respectively). The correlation for LVEF was also good (r=0.83, P<0.01). In conclusion: in patients with ischaemic cardiomyopathy, close and significant relations between gated SPET and 2D echocardiography were observed for the assessment of regional and global LV function and LV volumes; gated SPET has the advantage that it provides information on both LV function/dimensions and perfusion. (orig.)

  6. Assessment of Myocardial Bridge and Mural Coronary Artery Using ECG-Gated 256-Slice CT Angiography: A Retrospective Study

    Directory of Open Access Journals (Sweden)

    En-sen Ma

    2013-01-01

    Full Text Available Recent clinical reports have indicated that myocardial bridge and mural coronary artery complex (MB-MCA might cause major adverse cardiac events. 256-slice CT angiography (256-slice CTA is a newly developed CT system with faster scanning and lower radiation dose compared with other CT systems. The objective of this study is to evaluate the morphological features of MB-MCA and determine its changes from diastole to systole phase using 256-slice CTA. The imaging data of 2462 patients were collected retrospectively. Two independent radiologists reviewed the collected images and the diagnosis of MB-MCA was confirmed when consistency was obtained. The length, diameter, and thickness of MB-MCA in diastole and systole phases were recorded, and changes of MB-MCA were calculated. Our results showed that among the 2462 patients examined, 336 have one or multiple MB-MCA (13.6%. Out of 389 MB-MCA segments, 235 sites were located in LAD2 (60.41%. The average diameter change of MCA in LAD2 from systole phase to diastole phase was  mm, and 34.9% of MCA have more than 50% diameter stenosis in systole phase. This study suggested that 256-slice CTA multiple-phase reconstruction technique is a reliable method to determine the changes of MB-MCA from diastole to systole phase.

  7. Myocardial blood flow and left ventricular functional reserve in hypertrophic cardiomyopathy: a {sup 13}NH{sub 3} gated PET study

    Energy Technology Data Exchange (ETDEWEB)

    Sciagra, Roberto; Calabretta, Raffaella; Passeri, Alessandro; Castello, Angelo; Pupi, Alberto [University of Florence, Nuclear Medicine Unit, Department of Experimental and Clinical Biomedical Sciences ' ' Mario Serio' ' , Florence (Italy); Cipollini, Fabrizio [University of Florence, Department of Statistics, Florence (Italy); Cecchi, Franco; Olivotto, Iacopo [Careggi University Hospital, Referral Centre for Myocardial Diseases, Florence (Italy)

    2017-05-15

    Ischemia in hypertrophic cardiomyopathy (HCM) is caused by coronary microvascular dysfunction (CMD), which is detected by measuring myocardial blood flow (MBF) with PET. Whether CMD may be associated with ischemic left ventricular (LV) dysfunction is unclear. We therefore assessed LV ejection fraction (EF) reserve in HCM patients undergoing dipyridamole (Dip) PET. Resting and stress {sup 13}NH{sub 3} dynamic as well as gated PET were performed in 34 HCM patients. Segmental MBF and transmural perfusion gradient (TPG = subendocardial / subepicardial MBF) were assessed. LVEF reserve was considered abnormal if Dip LVEF decreased more than 5 units as compared to rest. Eighteen patients had preserved (group A) and 16 abnormal LVEF reserve (group B; range -7 to -32). Group B patients had greater wall thickness than group A, but resting volumes, LVEF, resting and Dip MBF, and myocardial flow reserve were similar. Group B had slightly higher summed stress score and summed difference score in visual analysis than group A, and a significantly higher summed stress wall motion score. In group B, resting TPG was slightly lower (1.31 ± 0.29 vs. 1.37 ± 0.34, p <0.05), and further decreased after Dip, whilst in group A it increased (B = 1.20 ± 0.39, p < 0.0001 vs. rest and vs. A = 1.40 ± 0.43). The number of segments per patient with TPG <1 was higher than in group A (p < 0.001) and was a significant predictor of impaired LVEF reserve (OR 1.86, p < 0.02), together with wall thickness (OR 1.3, p < 0.02). Abnormal LVEF response is common in HCM patients following Dip, and is related to abnormal TPG, suggesting that subendocardial ischemia might occur under Dip and cause transient LV dysfunction. Although in vivo this effect may be hindered by the adrenergic drive associated with effort, these findings may have relevance in understanding exercise limitation and heart failure symptoms in HCM. (orig.)

  8. Prevalence of positive gated myocardial SPECT in diabetic and non-diabetic women and impact of other factors; KIHD perspective

    International Nuclear Information System (INIS)

    Maseeh-uz-Zaman; Fatima, N.; Samad, A.; Rasheed, S.Z.; Ishaq, M.; Rehman, K.; Wali, A.

    2009-01-01

    The objective of the present study was to assess the prevalence of coronary artery disease (CAD) among diabetic (DM) and nondiabetic (NDM) women using Gated SPECT (GSPECT) and to study the impact of other. risk factors like hypertension (HTN), dyslipidemia, family history and menopause. This is a prospective cross-sectional study on a consecutive sample of 287 women referred to Nuclear Cardiology Department of Karachi Institute of Heart Diseases (KIHD) for GSPECT for evaluation of known or suspected CAD (from January 2009 till June 2009). Women with a history of DM diagnosed less than 5 years were excluded. Same day (reststress) GSPECT study was conducted and fixed or reversible perfusion defects were considered positive GSPECT for CAD. GSPECT was positive for CAD in 41/115 (36%, P 0.002) diabetic women and 37/172 (21 %, P 0.005) non-diabetic cohort. In diabetic cohort, GSPECT was positive in 5/9 (56%, P 0.013) women with diabetes only, 17/35 (48%, P 0.02) DM with HTN, 12/15 (80%, P value 0.02) DM with dyslipidemia and 11/43 (26%, P 0.001) DM with >2 risk factors. GSPECT was normal in all 3 diabetic women with positive family history for CAD. In nondiabetic cohort, GSPECT was positive in 9/32 (28%, P value 0.739) women with no risk factor, 5/58 (26%, P 0.866) HTN only, 2/5 (40%, P value 0.655) only dyslipidemic women, 1/12. (8%, P 0.004) with family history only and 4/23 (17%, P value 0.166) non-diabetic with >2 risk factors. Interestingly, 35/93 post-menopausal diabetic (38%, p value 0.017) had positive GSPECT while 33/123 non-diabetic postmenopausal women (27%, p 0.03) had positive perfusion scans. GSPECT was positive in 6/26 (23%, P 0.006) and 4/49 (8%, P 0.05) in diabetic and non-diabetic pre-menopausal women. The prevalence of CAD in our diabetic women is as high as internationally reported and diabetes is a strong risk factor for CAD. Dyslipidemia with diabetes is a major contributor to CAD than HTN and F/H. Diabetes erases the protective effect of estrogen

  9. SPET brain imaging with thallium 201 diethyldithiocarbamate in acute ischaemic stroke

    International Nuclear Information System (INIS)

    Bruine, J.F. de; Limburg, M.; Royen, E.A. van; Hijdra, A.; Hill, T.C.; Schoot, J.B. van der; Amsterdam Univ.; New England Deaconess Hospital, Boston, MA

    1990-01-01

    Thirty-five patients with acute ischaemic stroke were studied within 24 h after hospital admission with thallium diethyldithiocarbamate Tl 201 single photon emission tomography ( 201 Tl-DDC SPET) and X-ray computed tomography (CT). 201 Tl-DDC is a non-redistributing agent that allows postponed imaging after early administration and early therapeutic intervention. In 16 patients both investigations were performed within 24 h after stroke onset. The sensitivity of SPET was 94% and of CT 81% in the first 24 h, when hypodensity and obliteration of sulci were used as CT reading criteria. When only hypodensity was used as a criterion, the sensitivity of CT was 50% in this group. Sensitivity of CT compared with SPET became increasingly better in patients with older infarcts (1-18 days). In two-thirds of patients, the lesion demonstrated on SPET was larger than that on CT, and this was especially so with older infarcts. Crossed cerebellar diaschisis occurred in 69% of patients. The high sensitivity of 201 Tl-DDC SPET in the first 24 h after ischaemic stroke and the favourable properties of this radiopharmaceutical make it a method of interest in the assessment of initial perfusion defects in early experimental stroke therapies. (orig.)

  10. Analysis of the diagnostic value of the Gated-SPECT study of myocardial perfusion in the diagnosis of coronary disease in users seen at the Hospital Rafael Angel Calderon Guardia

    International Nuclear Information System (INIS)

    Calvo Montero, Karla; Coto Rodriguez, Maria Fernanda

    2011-01-01

    An analysis of the diagnostic value of the Gated-SPECT study of myocardial perfusion with Sestamibi marked with 99m Tc for the diagnosis of Coronary Disease was performed at the Hospital Rafael Angel Calderon Guardia. 13 patients with nuclear study and coronary angiography performed, were selected for the investigation. An estimate of the sensitivity, specificity and predictive values of the myocardial perfusion study was performed for the detection of the disease. Then, these values were related to socio-demographic and clinical characteristics of the patients submitted to the diagnosis. The need to use appropriate criteria to request this type of study was evidenced when determining that most of the patients presented risk factors compared to 26% of patients who did not present any factor [es

  11. Non-invasive detection of ischemic left ventricular dysfunction using rest gated SPECT. Expectation of simultaneous evaluation of both myocardial perfusion and wall motion abnormality

    International Nuclear Information System (INIS)

    Maeba, Hirofumi; Takehana, Kazuya; Nakamura, Seishi; Yoshida, Susumu; Ueyama, Takanao; Hatada, Kengo; Iwasaka, Toshiji

    2008-01-01

    Although the accurate detection of ischemic etiology is important in the management of patients with severe left ventricular (LV) dysfunction, it is difficult to determine using a non-invasive strategy. The present study investigates whether perfusion and regional functional abnormalities identified by quantitative electrocardiographic gated single-photon emission computed tomography (QGS) at rest can detect ischemic LV dysfunction in patients with severe LV dysfunction. Rest QGS with 99m Tc-tetrofosmin was performed on 54 consecutive patients with LV ejection fraction of ≤40%. Ischemic LV dysfunction (n=32) was defined according to the established standard. Regional perfusion and wall motion were calculated using a 14-segment model (six mid-ventricular and eight apical segments) and compared with a normal control group. The numbers of reduced [mean -1 standard deviation (SD) of normal individuals] and severely reduced (mean -2 SD) wall motion segments were similar between patients with ischemic and non-ischemic LV dysfunction (13.5±1.1 vs. 13.6±0.9 and 10.6±2.0 vs. 9.9±3.0 segments, respectively). The number of hypoperfused (mean -1 SD) segments was significantly greater in patients with ischemic LV dysfunction than in those with non-ischemic LV dysfunction (9.3±3.8 vs. 2.0±2.8 segments, P<0.0001). The analysis of the receiver operating characteristics showed that a cut-off value of 4 hypoperfused segments among 14 segments provided the best separation between ischemic and non-ischemic LV dysfunction (sensitivity=88% and specificity=91%). Furthermore, patients with non-ischemic LV dysfunction had no severely hypoperfused (mean -2 SD) segments in any of the segments, whereas patients with ischemic LV dysfunction had 4.4±0.2 segments. The QGS strategy at rest can accurately differentiate patients with ischemic LV dysfunction from those with severe LV dysfunction by simultaneous regional evaluation of wall motion and myocardial perfusion. (author)

  12. (1'23I)DaTSCAN and SPET imaging of dopamine carrier in Parkinson's disease (preliminary report)

    International Nuclear Information System (INIS)

    Chmielowski, K.; Szalus, N.; Pakszys, W.; Kulinski, W.; Skrobowska, E.

    2003-01-01

    The authors present own experience in dopamine carrier imaging by means of SPET and ( 123I ) DaTSCAN in Parkinson's disease. The aim of study was an assessment of the functional status of presynaptic dopaminergic system. The material consisted of three patients including one with spontaneous tremor and two with Parkinson's disease. The study was conducted according to EANM quidelines. The thyroid was blocked with sodium perchlorate administered orally (400 mg). ( 123I )DaTSCAN was injected intravenously. After three hours cerebral SPET was carried out using Varicam gamma camera. Reconstruction of SPET images was performed by the method of filtered retrograde projection using a Butterworth filter. SPET images of the brain were assessed visually and semiquantitatively through fusion and superimposing of SPET and MRI images together with marked templates (ROIs) for the corpus striatum.The obtained cerebral SPET results in three patients confirmed the diagnosis of spontaneous tremor in one case and Parkinson's disease in the remaining two subject. No adverse effects of ( 123I )DaTSCAN administration were found. Cocaine analogue, (sI)DaTSCAN, is an easy, safe and useful diagnostic test in SPET imaging of dopamine carrier in Parkinson's diseases and in spontaneous tremor. (author)

  13. Technetium-99m HMPAO SPET in acute supratentorial ischaemic infraction, expressing deficits as millilitre of zero perfusion

    International Nuclear Information System (INIS)

    Dierckx, R.A.; Deyn, P.P. de; Antwerp Univ.

    1995-01-01

    A comparative interim analysis was performed of clinical parameters, computed tomographic (CT) scan results and 99m Tc-HMPAO (SPET)-findings obtained within 12 h of acute supratentorial ischaemic infarction. First, the applicability for SPET semiquantification in this study of the ''method of Mountz'', simultaneously accounting for extent and degrees of hypoperfusion, was considered. Next, the relative contributions of perfusion SPET and CT scan in the acute stage of ischaemic infarction were compared in 27 patients (mean age 68.8 years). Finally, the correlation of SPET lesions with clinical parameters at onset was evaluated. The method of Mountz represents a workable, accurate virtual parameter, with the assumption that the contralateral brain region remains uninvolved. Because of inconstant distribution of activities in the brain, the method can only be applied slice by sclice and not on the total global volume. While the mean delay since the onset of symptomatology was approximately 7 h for both SPET and CT scan, SPET showed lesions concordant with the clinical neurological findings in 100% and CT scan in only 48%. One could hypothesize that SPET examinations performed later would show larger functional defects, because of the development of additional functional changes secondary to biochemical alterations. However, in this regard no statistically significant differences were found between two subproups, taking the median of delay before SPET examination as cut-off. Finally, when comparing the volumes of SPET lesions during the acute stage with clinical parameters, a statistically significant correlation (P<0.01) was found with the Orgogozo Scale scores describing the neurological deficit, but not with the Glasgow Coma Scale or Frenchay Aphasia Screening Test scores obtained on admittance. (orig./MG)

  14. Technetium-99m HMPAO SPET in acute supratentorial ischaemic infraction, expressing deficits as millilitre of zero perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Dierckx, R.A. [Univ. Hospital of Ghent (Belgium). Dept. of Nuclear Medicine and Radiotherapy]|[Antwerp Univ. (Belgium). Lab. of Neurochemistry and Behavior, Born-Bunge Foundation UIA; Dobbeleir, A. [Middelheim Hospital, Antwerp (Belgium). Dept. of Nuclear Medicine; Pickut, B.A. [Middelheim Hospital, Antwerp (Belgium). Dept. of Neurology; Timmermans, L. [Middelheim Hospital, Antwerp (Belgium). Dept. of Neurology; Dierckx, I. [Middelheim Hospital, Antwerp (Belgium). Dept. of Radiology; Vervaet, A. [Middelheim Hospital, Antwerp (Belgium). Dept. of Nuclear Medicine; Vandevivere, J. [Middelheim Hospital, Antwerp (Belgium). Dept. of Nuclear Medicine; Deberdt, W. [UCB Pharma NV (Belgium); Deyn, P.P. de [Middelheim Hospital, Antwerp (Belgium). Dept. of Neurology]|[Antwerp Univ. (Belgium). Lab. of Neurochemistry and Behavior, Born-Bunge Foundation UIA

    1995-05-01

    A comparative interim analysis was performed of clinical parameters, computed tomographic (CT) scan results and {sup 99m}Tc-HMPAO (SPET)-findings obtained within 12 h of acute supratentorial ischaemic infarction. First, the applicability for SPET semiquantification in this study of the ``method of Mountz``, simultaneously accounting for extent and degrees of hypoperfusion, was considered. Next, the relative contributions of perfusion SPET and CT scan in the acute stage of ischaemic infarction were compared in 27 patients (mean age 68.8 years). Finally, the correlation of SPET lesions with clinical parameters at onset was evaluated. The method of Mountz represents a workable, accurate virtual parameter, with the assumption that the contralateral brain region remains uninvolved. Because of inconstant distribution of activities in the brain, the method can only be applied slice by sclice and not on the total global volume. While the mean delay since the onset of symptomatology was approximately 7 h for both SPET and CT scan, SPET showed lesions concordant with the clinical neurological findings in 100% and CT scan in only 48%. One could hypothesize that SPET examinations performed later would show larger functional defects, because of the development of additional functional changes secondary to biochemical alterations. However, in this regard no statistically significant differences were found between two subproups, taking the median of delay before SPET examination as cut-off. Finally, when comparing the volumes of SPET lesions during the acute stage with clinical parameters, a statistically significant correlation (P<0.01) was found with the Orgogozo Scale scores describing the neurological deficit, but not with the Glasgow Coma Scale or Frenchay Aphasia Screening Test scores obtained on admittance. (orig./MG)

  15. Clinical impact of diagnostic SPET investigations with a dopamine re-uptake ligand

    International Nuclear Information System (INIS)

    Loekkegaard, Annemette; Werdelin, Lene M.; Friberg, Lars

    2002-01-01

    The diagnosis of Parkinson's disease is based on clinical features with pathological verification. However, autopsy has been found to confirm a specialist diagnosis in only about 75% of cases. Especially early in the course of the disease, the clinical diagnosis can be difficult. Imaging of presynaptic dopamine transporters (DAT receptors) has provided a possible diagnostic probe in the evaluation of Parkinson's disease. The cocaine analogue [ 123 I]-2-β-carboxymethoxy-3-β(4-iodophenyl)tropane ([ 123 I]-β-CIT) is one of several radioligands that have been developed for single-photon emission tomography (SPET). The purpose of this study was to evaluate the impact of [ 123 I]-β-CIT SPET on the diagnosis and clinical management of patients with a primary, tentative diagnosis of parkinsonism. We undertook a retrospective evaluation of the clinical records of 90 consecutive patients referred to [ 123 I]-β-CIT SPET from the neurological department, Bispebjerg Hospital. In 58 subjects the scans revealed altered tracer uptake consistent with Parkinson's disease, progressive supranuclear palsy and multiple system atrophy. A significant change in the management or treatment because of the scan was found in 25 patients (28%). The sensitivity of the examination was 97% and the specificity 83%. In conclusion, a significant clinical impact of DAT receptor SPET imaging was found. DAT receptor imaging is a useful diagnostic probe in patients with a possible diagnosis of parkinsonism. (orig.)

  16. A bolus/infusion paradigm for the novel NMDA receptor SPET tracer [{sup 123}i]CNS 1261

    Energy Technology Data Exchange (ETDEWEB)

    Bressan, Rodrigo A; Erlandsson, Kjell E-mail: k.erlandsson@nucmed.ucl.ac.uk; Mulligan, Rachel S; Gunn, Roger N.; Cunningham, Vincent J.; Owens, Jonathan; Cullum, Ian D.; Ell, Peter J.; Pilowsky, Lyn S

    2004-02-01

    We have previously performed quantitative kinetic modeling of [{sup 123}I]CNS 1261, a new SPET ligand for the MK801 intrachannel site of the NMDA receptor. We now report a bolus-infusion protocol, which eliminates the need for arterial blood sampling. Dynamic SPET scanning and venous blood sampling were performed in 7 healthy volunteers. Good agreement was obtained between kinetic and equilibrium analysis. SPET scanning with a bolus-infusion protocol is a valid method to estimate the total volume of distribution for [{sup 123}I]CNS 1261 in clinical populations.

  17. Comparison of sulfur hexafluoride microbubble (SonoVue)-enhanced myocardial contrast echocardiography with gated single-photon emission computed tomography for detection of significant coronary artery disease: a large European multicenter study.

    Science.gov (United States)

    Senior, Roxy; Moreo, Antonella; Gaibazzi, Nicola; Agati, Luciano; Tiemann, Klaus; Shivalkar, Bharati; von Bardeleben, Stephan; Galiuto, Leonarda; Lardoux, Hervé; Trocino, Giuseppe; Carrió, Ignasi; Le Guludec, Dominique; Sambuceti, Gianmario; Becher, Harald; Colonna, Paolo; Ten Cate, Folkert; Bramucci, Ezio; Cohen, Ariel; Bezante, Gianpaolo; Aggeli, Costantina; Kasprzak, Jaroslaw D

    2013-10-08

    The purpose of this study was to compare sulfur hexafluoride microbubble (SonoVue)-enhanced myocardial contrast echocardiography (MCE) with single-photon emission computed tomography (SPECT) relative to coronary angiography (CA) for assessment of coronary artery disease (CAD). Small-scale studies have shown that myocardial perfusion assessed by SonoVue-enhanced MCE is a viable alternative to SPECT for CAD assessment. However, large multicenter studies are lacking. Patients referred for myocardial ischemia testing at 34 centers underwent rest/vasodilator SonoVue-enhanced flash-replenishment MCE, standard (99m)Tc-labeled electrocardiography-gated SPECT, and quantitative CA within 1 month. Myocardial ischemia assessments by 3 independent, blinded readers for MCE and 3 readers for SPECT were collapsed into 1 diagnosis per patient per technique and were compared to CA (reference standard) read by 1 independent blinded reader. Of 628 enrolled patients who received SonoVue (71% males; mean age: 64 years; >1 cardiovascular [CV] risk factor in 99% of patients) 516 patients underwent all 3 examinations, of whom 161 (31.2%) had ≥70% stenosis (131 had single-vessel disease [SVD]; 30 had multivessel disease), and 310 (60.1%) had ≥50% stenosis. Higher sensitivity was obtained with MCE than with SPECT (75.2% vs. 49.1%, respectively; p SonoVue-enhanced MCE demonstrated superior sensitivity but lower specificity for detection of CAD compared to SPECT in a population with a high incidence of CV risk factors and intermediate-high prevalence of CAD. (A phase III study to compare SonoVue® enhanced myocardial echocardiography [MCE] to single photon emission computerized tomography [ECG-GATED SPECT], at rest and at peak of low-dose Dipyridamole stress test, in the assessment of significant coronary artery disease [CAD] in patients with suspect or known CAD using Coronary Angiography as Gold Standard-SonoVue MCE vs SPECT; EUCTR2007-003492-39-GR). Copyright © 2013 American College of

  18. False-positive defects in technetium-99m sestamibi myocardial single-photon emission tomography in healthy athletes with left ventricular hypertrophy

    Energy Technology Data Exchange (ETDEWEB)

    Bartram, P.; Hanel, B.; Gustafsson, F.; Mortensen, J.; Hesse, B. [Department of Clinical Physiology and Nuclear Medicine, Copenhagen University Hospital (Denmark); Toft, J. [Department of Clinical Physiology and Nuclear Medicine, Copenhagen University Hospital (Denmark)]|[Copenhagen City Heart Study, Epidemiological Research Unit (Denmark); Ali, S. [Dept. of Cardiology, Copenhagen University Hospital (Denmark)

    1998-09-01

    Exercise ECG and myocardial single-photon emission tomography (SPET) are fundamental in the non-invasive evaluation of patients suspected of having coronary artery disease (CAD). The purpose of the present study was to investigate the influence of physiological left ventricular hypertrophy (LVH) on myocardial sestamibi SPET in healthy young and old athletes. Eighteen young male elite athletes (ten rowers, five power/weight lifters and three triathletes) and 14 well-trained elderly rowers were studied. All underwent a bicycle test as part of a 2-day sestamibi SPET protocol. Attenuation correction was not performed. The studies were evaluated visually and quantitatively analysed by the CEqual program with its reference files and with a file from a local non-athletic age-matched population. Echocardiographic LVH was an inclusion criterion in the young athletes. Exercise ECG was normal in all subjects. In at least three of the young athletes a reversible defect was observed by visual analysis. On quantitative analysis one-third of the young athletes had ``significant`` (>10 pixels) defects compared with both the local reference base and the CEqual reference population. Nearly all defects were found in the anterior or inferior wall. The remaining subjects, including all old rowers, had normal SPET findings. Anterior and inferior wall defects are so common in healthy athletes with physiological LVH that the specificity of myocardial SPET, in contrast to exercise ECG, seems to be too low for evaluation of chest pain in this group. The mechanism of anterior and inferior defects may be related to hot spots (papillary muscles?) in the lateral wall. The specificity of SPET is maintained in athletes without LVH. (orig.) With 1 fig., 26 tabs., 22 refs.

  19. False-positive defects in technetium-99m sestamibi myocardial single-photon emission tomography in healthy athletes with left ventricular hypertrophy

    International Nuclear Information System (INIS)

    Bartram, P.; Hanel, B.; Gustafsson, F.; Mortensen, J.; Hesse, B.; Toft, J.; Ali, S.

    1998-01-01

    Exercise ECG and myocardial single-photon emission tomography (SPET) are fundamental in the non-invasive evaluation of patients suspected of having coronary artery disease (CAD). The purpose of the present study was to investigate the influence of physiological left ventricular hypertrophy (LVH) on myocardial sestamibi SPET in healthy young and old athletes. Eighteen young male elite athletes (ten rowers, five power/weight lifters and three triathletes) and 14 well-trained elderly rowers were studied. All underwent a bicycle test as part of a 2-day sestamibi SPET protocol. Attenuation correction was not performed. The studies were evaluated visually and quantitatively analysed by the CEqual program with its reference files and with a file from a local non-athletic age-matched population. Echocardiographic LVH was an inclusion criterion in the young athletes. Exercise ECG was normal in all subjects. In at least three of the young athletes a reversible defect was observed by visual analysis. On quantitative analysis one-third of the young athletes had ''significant'' (>10 pixels) defects compared with both the local reference base and the CEqual reference population. Nearly all defects were found in the anterior or inferior wall. The remaining subjects, including all old rowers, had normal SPET findings. Anterior and inferior wall defects are so common in healthy athletes with physiological LVH that the specificity of myocardial SPET, in contrast to exercise ECG, seems to be too low for evaluation of chest pain in this group. The mechanism of anterior and inferior defects may be related to hot spots (papillary muscles?) in the lateral wall. The specificity of SPET is maintained in athletes without LVH. (orig.)

  20. {sup 18}FDG PET and acetazolamide-enhanced {sup 99m}Tc-HMPAO SPET in systemic lupus erythematosus

    Energy Technology Data Exchange (ETDEWEB)

    Gruenwald, F. [Bonn Univ. (Germany). Inst. fuer Klinische und Experimentelle Nuklearmedizin; Schomburg, A. [Bonn Univ. (Germany). Inst. fuer Klinische und Experimentelle Nuklearmedizin; Badali, A. [Dept. of Dermatology, Univ. of Bonn (Germany); Ruhlmann, J. [Bonn Univ. (Germany). Inst. fuer Klinische und Experimentelle Nuklearmedizin; Pavics, L. [Bonn Univ. (Germany). Inst. fuer Klinische und Experimentelle Nuklearmedizin; Biersack, H.J. [Bonn Univ. (Germany). Inst. fuer Klinische und Experimentelle Nuklearmedizin

    1995-09-01

    In this report, we present the case of a 70-year-old female patient, suffering from SLE without symptoms of CNS involvement. In addition to a SPET study using technetium-99m hexamethylpropylene amine oxime ({sup 99m}Tc-HMPAO) and a PET scan with fluorine-18 deoxyglucose ({sup 18}FDG), a SPET study after acetazolamide injection was performed in order to assess the cerebral perfusion reserve. While the PET scan showed no major abnormalities, and the baseline SPET study revealed only minor changes, the acetazolamide-enhanced SPET study revealed a marked reduction of the cortical perfusion reserve, particularly in both frontal lobes. It is concluded that ``preclinical`` CNS involvement, mainly caused by pathological mechanisms involving the cerebral blood vessels, can be considered to exist in this patient with SLE. (orig.). With 2 figs.

  1. ECG-manifest and ECG-silent dipyridamole technetium-99m sestamibi SPET perfusion defects in patients with ischaemic heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Galli, M. [Cardiology Division, `Salvatore Maugeri` Foundation IRCCS, Veruno (Italy); Marcassa, C. [Cardiology Division, `Salvatore Maugeri` Foundation IRCCS, Veruno (Italy); Bosimini, E. [Cardiology Division, `Salvatore Maugeri` Foundation IRCCS, Veruno (Italy); Zoccarato, O. [Nuclear Medicine Laboratory, `Salvatore Maugeri` Foundation IRCCS, Veruno (Italy); Comazzi, F. [Medical Engineering Service, `Salvatore Maugeri` Foundation IRCCS, Veruno (Italy); Giannuzzi, P. [Cardiology Division, `Salvatore Maugeri` Foundation IRCCS, Veruno (Italy)

    1997-02-01

    To investigate the relationship between ECG changes and perfusion abnormalities, body surface maps were recorded during dipyridamole infusion in 55 subjects (11 normals and 44 patients with ischaemic heart disease) undergoing dipyridamole technetium-99m sestamibi single-photon emission tomography (SPET). All had a normal resting ECG. The extent and severity of the sestamibi defect were quantified. New negative areas in the isointegral maps and rest-dipyridamole map differences >2 SD from normal limits were considered abnormal. After dipyridamole in normals, neither perfusion defects nor {>=}1 mm ST segment depression on 12-lead ECG nor new negative areas in isointegral maps occurred. In patients, dipyridamole induced new perfusion defects in 35 (80%) but ST segment depression in only 18 (41%, P<0.001). Of the 35 patients with perfusion defects, 17 (49%, group 1) showed ST segment depression, while the other 18 (51%, group 2) did not. Abnormal body surface maps were found in 100% of group 1 and 88% of group 2 patients (NS). In group 1, the provoked hypoperfusion was of greater extent (P=0.007) and severity (P=0.01) and the onset of map abnormalities was significantly earlier (P<0.001) than in group 2; time to map abnormalities was also significantly shorter than time to ST segment depression (P=0.01). In the 35 patients with complete scintigraphic, body map and angiographic data, the severity of reversible perfusion defect proved to be the strongest correlate of ST segment depression upon logistic regression analysis. Thus, sestamibi SPET abnormalities after dipyridamole are almost always associated with electrical changes on body surface maps, suggesting myocardial ischaemia as their cause. The much less common 12-lead ECG changes are slower to appear and reflect a more severe hypoperfusion. (orig./MG). With 5 figs., 4 tabs.

  2. Evaluation of left ventricular function and volume in patients with dilated cardiomyopathy: Gated myocardial single-photon emission tomography (SPECT) versus echocardiography

    International Nuclear Information System (INIS)

    Berk, Fatma; Isgoren, S.; Demir, H.; Kozdag, G.; Ural, D.; Komsuoglu, B.

    2005-01-01

    Left ventricular function, volumes and regional wall motion provide valuable diagnostic information and are of long-term prognostic importance in patients with dilated cardiomyopathy (DCM). This study was designed to compare the effectiveness of 2D-echocardiography and gated single-photon emission tomography (SPECT) for evaluation of these parameters in patients with DCM. Gated SPECT and 2D-echocardiography were performed in 33 patients having DCM. Gated SPECT data, including left ventricular ejection fraction (LVEF), were processed using an automated algorithm. Standard technique was used for 2D-echocardiography. Regional wall motion was evaluated using both modalities and was scored by two independent observers using a 16-sement model with a 5-point scoring system. The overall agreement between the two imaging modalities for the assessment of regional wall motion was 56% (298/528 segments). With gated SPECT, LEVF, end-diastolic volume (EDV), and end-diastolic volume (EDV), and end-systolic volume (ESV) were 27+-9%, 217+-73mL, respectively, and 30.8%, 195+-58mL and, 137+-48 mL with echocardiography. The correlation between gated SPECT and 2-D-echocardiography was good (r=0.76, P<0.01) for the assessment of LVEF. The correlation for EDV and ESV were also good, but with wider limits of agreement (r=0.72, P<0.01 and r=0.73, P<0.01, respectively) and significantly higher values were obtained with gated SPECT (P<0.01). Gated SPECT and 2D-echocardiography correlate well for the assessment of LV function and LV volumes. Like 2D-echocardiography, gated SPECT provides reliable information about LV function and dimension with the additional advantage of perfusion data. (author)

  3. Sodium bicarbonate-augmented stress thallium myocardial scintigraphy

    International Nuclear Information System (INIS)

    Sarin, Badal; Chugh, Pradeep Kumar; Kaushal, Dinesh; Soni, Nakse Lal; Sawroop, Kishan; Mondal, Anupam; Bhatnagar, Aseem

    2004-01-01

    It is well known that sodium bicarbonate in pharmacological doses induces transient alkalosis, causing intracellular transport of serum potassium. The aims of this study were (a) to investigate whether, in humans, myocardial thallium-201 uptake can be augmented by pretreatment with a single bolus of sodium bicarbonate at a pharmacological dose, (b) to verify general safety aspects of the intervention and (c) to evaluate the clinical implications of augmentation of 201 Tl uptake, if any. Routine exercise myocardial scintigraphy was performed twice in eight adult volunteers (five normal and three abnormal), once without intervention and the second time (within a week) following intravenous administration of sodium bicarbonate (88 mEq in 50 ml) as a slow bolus 1 h prior to the injection of 201 Tl. Conventional myocardial thallium study was compared with sodium bicarbonate interventional myocardial scintigraphy with respect to myocardial uptake (counts per minute per mCi injected dose), washout patterns in normal and abnormal myocardial segments, and overall clinical interpretation based on planar and single-photon emission tomographic (SPET) images. All patients remained asymptomatic after the intervention. A mean increase of 53% in myocardial uptake of thallium was noted in post-exercise acquisitions after the intervention, confirming uptake of the tracer via the potassium-hydrogen pump and its augmentation by transient alkalosis. The washout pattern remained unchanged. The visual quality of planar and SPET images improved significantly after the intervention. Out of the five abnormal myocardial segments identified in three cases, four showed significant filling-in after the intervention, causing the diagnosis to be upgraded from ''partial scar'' to ''ischaemia'', or from ''ischaemia'' to ''normal''. The overall scan impression changed in two out of three such cases. Sodium bicarbonate augmentation may have significant implications for stress-thallium scintigraphy

  4. Combined use of 64-slice computed tomography angiography and gated myocardial perfusion SPECT for the detection of functionally relevant coronary artery stenoses. First results in a clinical setting concerning patients with stable angina

    International Nuclear Information System (INIS)

    Hacker, M.; Hack, N.; Tiling, R.; Jakobs, T.; Nikolaou, K.; Becker, C.; Ziegler, F. von; Knez, A.; Koenig, A.; Klauss, V.

    2007-01-01

    Aim: In patients with stable angina pectoris both morphological and functional information about the coronary artery tree should be present before revascularization therapy is performed. High accuracy was shown for spiral computed tomography (MDCT) angiography acquired with a 64-slice CT scanner compared to invasive coronary angiography (ICA) in detecting obstructive'' coronary artery disease (CAD). Gated myocardial SPECT (MPI) is an established method for the noninvasive assessment of functional significance of coronary stenoses. Aim of the study was to evaluate the combination of 64-slice CT angiography plus MPI in comparison to ICA plus MPI in the detection of hemodynamically relevant coronary artery stenoses in a clinical setting. Patients, methods: 30 patients (63 ± 10.8 years, 23 men) with stable angina (21 with suspected, 9 with known CAD) were investigated. MPI, 64-slice CT angiography and ICA were performed, reversible and fixed perfusion defects were allocated to determining lesions separately for MDCT angiography and ICA. The combination of MDCT angiography plus MPI was compared to the results of ICA plus MPI. Results: Sensitivity, specificity, negative and positive predictive value for the combination of MDCT angiography plus MPI was 85%, 97%, 98% and 79%, respectively, on a vessel-based and 93%, 87%, 93% and 88%, respectively, on a patient-based level. 19 coronary arteries with stenoses =50% in both ICA and MDCT angiography showed no ischemia in MPI. Conclusion: The combination of 64-slice CT angiography and gated myocardial SPECT enabled a comprehensive non-invasive view of the anatomical and functional status of the coronary artery tree. (orig.)

  5. Ictal brain SPET during seizures pharmacologically provoked with pentylenetetrazol: a new diagnostic procedure in drug-resistant epileptic patients

    International Nuclear Information System (INIS)

    Calcagni, Maria Lucia; Giordano, Alessandro; Bruno, Isabella; Di Giuda, Daniela; De Rossi, Giuseppe; Troncone, Luigi; Parbonetti, Giovanni; Colicchio, Gabriella

    2002-01-01

    Functional brain imaging plays an important role in seizure focus localisation. However, truly ictal single-photon emission tomography (SPET) studies are not routinely performed owing to technical problems associated with the use of tracers and methodological and logistical difficulties. In this study we tried to resolve both of these issues by means of a new procedure: technetium-99m ethyl cysteinate dimer (ECD) brain SPET performed during seizures pharmacologically provoked with pentylenetetrazol, a well-known central and respiratory stimulant. We studied 33 drug-resistant epileptic patients. All patients underwent anamnestic evaluation, neuropsychological and psychodynamic assessment, magnetic resonance imaging, interictal and ictal video-EEG monitoring, and interictal and ictal SPET with 99m Tc-ECD. In order to obtain truly ictal SPET, 65 mg of pentylenetetrazol was injected every 2 minutes and, immediately the seizure began, 740 MBq of 99m Tc-ECD was injected. The scintigraphic findings were considered abnormal if a single area of hyperperfusion was present and corresponded to the site of a single area of hypoperfusion at interictal SPET: the ''hypo-hyperperfusion'' SPET pattern. In 27 of the 33 patients (82%), interictal-ictal SPET showed the hypo-hyperperfusion SPET pattern. Video-EEG showed a single epileptogenic zone in 21/33 patients (64%), and MRI showed anatomical lesions in 19/33 patients (57%). Twenty-two of the 27 patients with hypo-hyperperfusion SPET pattern underwent ablative or palliative surgery and were seizure-free at 3 years of follow-up. No adverse effects were noted during pharmacologically provoked seizure. It is concluded that ictal brain SPET performed during pharmacologically provoked seizure provides truly ictal images because 99m Tc-ECD is injected immediately upon seizure onset. Using this feasible procedure it is possible to localise the focus, to avoid the limitations due to the unpredictability of seizures, to avoid pitfalls due

  6. Ictal brain SPET during seizures pharmacologically provoked with pentylenetetrazol: a new diagnostic procedure in drug-resistant epileptic patients

    Energy Technology Data Exchange (ETDEWEB)

    Calcagni, Maria Lucia; Giordano, Alessandro; Bruno, Isabella; Di Giuda, Daniela; De Rossi, Giuseppe; Troncone, Luigi [Department of Nuclear Medicine, Universita Cattolica del Sacro Cuore, Largo A. Gemelli, 8, 00168 Roma (Italy); Parbonetti, Giovanni; Colicchio, Gabriella [Department of Neurosurgery, Universita Cattolica del Sacro Cuore, Roma (Italy)

    2002-10-01

    Functional brain imaging plays an important role in seizure focus localisation. However, truly ictal single-photon emission tomography (SPET) studies are not routinely performed owing to technical problems associated with the use of tracers and methodological and logistical difficulties. In this study we tried to resolve both of these issues by means of a new procedure: technetium-99m ethyl cysteinate dimer (ECD) brain SPET performed during seizures pharmacologically provoked with pentylenetetrazol, a well-known central and respiratory stimulant. We studied 33 drug-resistant epileptic patients. All patients underwent anamnestic evaluation, neuropsychological and psychodynamic assessment, magnetic resonance imaging, interictal and ictal video-EEG monitoring, and interictal and ictal SPET with {sup 99m}Tc-ECD. In order to obtain truly ictal SPET, 65 mg of pentylenetetrazol was injected every 2 minutes and, immediately the seizure began, 740 MBq of {sup 99m}Tc-ECD was injected. The scintigraphic findings were considered abnormal if a single area of hyperperfusion was present and corresponded to the site of a single area of hypoperfusion at interictal SPET: the ''hypo-hyperperfusion'' SPET pattern. In 27 of the 33 patients (82%), interictal-ictal SPET showed the hypo-hyperperfusion SPET pattern. Video-EEG showed a single epileptogenic zone in 21/33 patients (64%), and MRI showed anatomical lesions in 19/33 patients (57%). Twenty-two of the 27 patients with hypo-hyperperfusion SPET pattern underwent ablative or palliative surgery and were seizure-free at 3 years of follow-up. No adverse effects were noted during pharmacologically provoked seizure. It is concluded that ictal brain SPET performed during pharmacologically provoked seizure provides truly ictal images because {sup 99m}Tc-ECD is injected immediately upon seizure onset. Using this feasible procedure it is possible to localise the focus, to avoid the limitations due to the unpredictability

  7. SPET/CT image co-registration in the abdomen with a simple and cost-effective tool

    International Nuclear Information System (INIS)

    Foerster, Gregor J.; Laumann, Christina; Nickel, Otmar; Bartenstein, Peter; Kann, Peter; Rieker, Olaf

    2003-01-01

    Fusion of morphology and function has been shown to improve diagnostic accuracy in many clinical circumstances. Taking this into account, a number of instruments combining computed tomography (CT) with positron emission tomography (PET) or single-photon emission tomography (SPET) are appearing on the market. The aim of this study was to evaluate a simple and cost-effective approach to generate fusion images of similar quality. For the evaluation of the proposed approach, patients with neuroendocrine abdominal tumours with liver metastases were chosen, since the exact superimposition in the abdomen is more difficult than in other regions. Five hours following the injection of 110 MBq 111 In-DTPA-octreotide, patients were fixed in a vacuum cushion (MED-TEC, Vac-Loc) and investigated with helical CT in a mid-inspiration position (n=14). Directly following the CT, a SPET study (SPET1) of the abdominal region was performed without changing the position of the patient. A second SPET study (SPET2), 24 h p.i., was acquired after repositioning the patient in his or her individually moulded vacuum cushion. A total of nine markers suitable for imaging with CT and SPET were fixed on the cushion. Datasets were fused by means of internal landmarks (e.g. metastases or margin of abdominal organs) or by the external markers. Image fusion using external markers was fast and easy to handle compared with the use of internal landmarks. Using this technique, all lesions detectable by SPET (n=28) appeared exactly superpositioned on the respective CT morphology by visual inspection. Image fusion of CT/SPET1 and CT/SPET2 showed a mean deviation of the external markers that in the former case was smaller than the voxel size of 4.67 mm: 4.17±0.61 (CT/SPET1; ±SD) and 5.52±1.56 mm (CT/SPET2), respectively. Using internal landmarks, the mean deviation of the chosen landmarks was 6.47±1.37 and 7.78±1.21 mm. Vector subtraction of corresponding anatomical points of the CT and the re

  8. Impact of intracoronary injection of mononuclear bone marrow cells in acute myocardial infarction on left ventricular perfusion and function: a 6-month follow-up gated {sup 99m}Tc-MIBI single-photon emission computed tomography study

    Energy Technology Data Exchange (ETDEWEB)

    Lipiec, Piotr [Medical University of Lodz, 2nd Department of Cardiology, Lodz (Poland); Medical University of Lodz, 2nd Department of Cardiology, Bieganski Hospital, Lodz (Poland); Krzeminska-Pakula, Maria; Plewka, Michal; Kasprzak, Jaroslaw D. [Medical University of Lodz, 2nd Department of Cardiology, Lodz (Poland); Kusmierek, Jacek; Plachcinska, Anna; Szuminski, Remigiusz [Medical University of Lodz, Department of Nuclear Medicine, Lodz (Poland); Robak, Tadeusz; Korycka, Anna [Medical University of Lodz, Department of Hematology, Lodz (Poland)

    2009-04-15

    We investigated the impact of intracoronary injection of autologous mononuclear bone marrow cells (BMC) in patients with acute ST elevation myocardial infarction (STEMI) on left ventricular volumes, global and regional systolic function and myocardial perfusion. The study included 39 patients with first anterior STEMI treated successfully with primary percutaneous coronary intervention. They were randomly assigned to the treatment group or the control group in a 2:1 ratio. The patients underwent baseline gated single-photon emission computed tomography (G-SPECT) 3-10 days after STEMI with quantitative and qualitative analysis of left ventricular perfusion and systolic function. On the following day, patients from the BMC treatment group were subjected to bone marrow aspiration, mononuclear BMC isolation and intracoronary injection. No placebo procedure was performed in the control group. G-SPECT was repeated 6 months after STEMI. Baseline and follow-up G-SPECT studies were available for 36 patients. At 6 months in the BMC group we observed a significantly enhanced improvement in the mean extent of the perfusion defect, the left ventricular perfusion score index, the infarct area perfusion score and the infarct area wall motion score index compared to the control group (p=0.01-0.04). However, the changes in left ventricular volume, ejection fraction and the left ventricular wall motion score index as well as the relative changes in the infarct area wall motion score index did not differ significantly between the groups. Intracoronary injection of autologous mononuclear BMC in patients with STEMI improves myocardial perfusion at 6 months. The benefit in infarct area systolic function is less pronounced and there is no apparent improvement of global left ventricular systolic function. (orig.)

  9. Comparison of myocardial fatty acid metabolism with left ventricular function and perfusion in cardiomyopathies. By 123I-BMIPP SPECT and 99mTc-tetrofosmin electrocardiographically gated SPECT

    International Nuclear Information System (INIS)

    Zhao, Chunlei; Shuke, Noriyuki; Okizaki, Atsutaka

    2003-01-01

    The objective of this study was to investigate myocardial fatty acid metabolism and its relationship with left ventricular (LV) function and perfusion in hypertrophic cardiomyopathy (HCM) and dilated cardiomyopathy (DCM). Thirty-nine patients with cardiomyopathies (58±14 y), comprising 15 DCM and 24 HCM, and 9 age-matched healthy controls were studied with 123 I-15-(p-iodophenyl)-3-(R,S)-methylpentadecanoic acid (BMIPP) and 99m Tc-tetrofosmin (TF) electrocardiographically gated SPECT. As parameters of myocardial fatty acid metabolism, the heart-to-mediastinum ratio (H/M) and global washout of BMIPP were calculated from early and delayed planar images, while regional BMIPP uptake and washout were calculated from SPECT. In TF study, the H/M (H/M-TF) and LV ejection fraction (LVEF) were calculated as global parameters of perfusion and function, while regional TF uptake and wall thickening index were calculated as regional parameters of perfusion and function using the Quantitative Gated SPECT software. The differences in the parameters and the correlations between the parameters from the 2 studies were investigated by one-way ANOVA and multiple linear regression analysis. BMIPP uptake was decreased (p 0.05), but showed a significant correlation with H/M-TF (p 0.05) but had a significant correlation with regional perfusion (p<0.0001) in DCM. In HCM, regional BMIPP parameters showed significant multiple linear correlations with both regional function (p<0.005) and perfusion (p<0.0001). According to the partial correlation coefficients, delayed regional BMIPP uptake was the most significant factor for predicting regional function in HCM, while early regional BMIPP uptake was the only or the most significant factor for predicting regional perfusion in DCM and HCM, respectively. In DCM, BMIPP uptake and washout could not reflect LV function. In HCM, regional delayed BMIPP uptake might be useful for evaluating regional function. In DCM and HCM, early BMIPP uptake might be

  10. Dobutamine stress thallium-201 single-photon emission tomography versus echocardiography for evaluation of the extent and location of coronary artery disease late after myocardial infarction

    International Nuclear Information System (INIS)

    Elhendy, A.; Bax, J.J.; Domburg, R.T. van; Cornel, J.H.; Roelandt, J.R.T.C.; Valkema, R.; Reijs, A.E.M.; Krenning, E.P.

    1999-01-01

    Dobutamine stress echocardiography and thallium-201 myocardial perfusion scintigraphy are clinically useful methods for the evaluation of coronary artery disease (CAD). However, the relative merits of these imaging modalities in the evaluation of the extent of CAD after myocardial infarction have not been well studied. The aim of this study was to compare the accuracy of dobutamine stress echocardiography and simultaneous 201 Tl single-photon emission tomography (SPET) imaging for the diagnosis and localization of CAD late after acute myocardial infarction. Dobutamine (up to 40 μg kg -1 min -1 )-atropine (up to 1 mg) stress echocardiography in conjunction with stress-reinjection 201 Tl SPET was performed for the evaluation of myocardial ischaemia in 90 patients with previous myocardial infarction who underwent coronary angiography. Significant CAD was predicted on bases of myocardial ischemia (new or worsening wall motion abnormalities on echocardiography and reversible perfusion defects on 201 Tl SPET). Significant CAD (≥ 50% luminal diameter stenosis) was detected in 73 (81%) patients. The sensitivity, specificity and accuracy of echocardiography in detecting remote ischaemia for the diagnosis of remote CAD (present in 53 patients) were, respectively, 79% (CI 70%-88%), 85% (CI 77%-93%) and 81% (CI 73%-90%), while the corresponding figures for 201 Tl SPET were 75% (CI 66%-85%), 78% (CI 69%-87%) and 76% (CI 67%-86%) respectively (P = NS vs echocardiography). The sensitivity, specificity and accuracy of echocardiography in detecting peri-infarction ischaemia for the diagnosis of infarct-related artery stenosis (present in 70 patients) were, rspectively, 77% (CI 68%-86%), 85% (CI 78%-92%) and 79% (CI 70%-87%) while the corresponding figures for 201 Tl SPET were 73% (CI 64%-82%), 85% (CI 78%-92%) and 76% (CI 67%-84%) respectively (P = NS vs echocardiography). The agreement between the two methods for the diagnosis of peri-infarction and remote ischaemia was 70

  11. Myocardial Bridge

    Science.gov (United States)

    ... Center > Myocardial Bridge Menu Topics Topics FAQs Myocardial Bridge Article Info En español Your heart is made ... surface of the heart. What is a myocardial bridge? A myocardial bridge is a band of heart ...

  12. Cardiac gated ventilation

    Science.gov (United States)

    Hanson, C. William, III; Hoffman, Eric A.

    1995-05-01

    There are several theoretic advantages to synchronizing positive pressure breaths with the cardiac cycle, including the potential for improving distribution of pulmonary and myocardial blood flow and enhancing cardiac output. We evaluated the effects of synchronizing respiration to the cardiac cycle using a programmable ventilator and electron beam CT (EBCT) scanning. The hearts of anesthetized dogs were imaged during cardiac gated respiration with a 50msec scan aperture. Multislice, short axis, dynamic image data sets spanning the apex to base of the left ventricle were evaluated to determine the volume of the left ventricular chamber at end-diastole and end-systole during apnea, systolic and diastolic cardiac gating. We observed an increase in cardiac output of up to 30% with inspiration gated to the systolic phase of the cardiac cycle in a nonfailing model of the heart.

  13. A study of the acute effect of smoking on cerebral blood flow using 99mTc-ECD SPET

    International Nuclear Information System (INIS)

    Yamamoto, Yuka; Nishiyama, Yoshihiro; Monden, Toshihide; Satoh, Katashi; Ohkawa, Motoomi

    2003-01-01

    Cigarette smoking is known to be associated with atherosclerosis, is an important risk factor for stroke and has other serious effects. The aim of this study was to evaluate the acute effect of cigarette smoking on cerebral blood flow using statistical parametric mapping (SPM). Ten healthy volunteers with a smoking habit were studied using technetium-99m-labelled ethylcysteinate dimer single-photon emission tomography (SPET). We evaluated the regional cerebral blood flow under the smoking and resting states. The regional cerebral blood flow on smoking-activated SPET was significantly decreased in the whole brain as compared with that on resting SPET. Our findings therefore suggest that one of the acute effects of cigarette smoking is to induce a diffuse decrease in cerebral blood flow. (orig.)

  14. Predictive and prognostic values of transient ischemic dilatation of left ventricular cavity for coronary artery disease and impact of various managements on clinical outcome using technetium-99m sestamibi gated myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Zaman, M.U.; Fatima, N.; Samad, A.; Ishaq, M.; Wali, A.; Rehman, K.; Bano, J.

    2011-01-01

    Transient ischemic dilatation (TID) of left ventricular (LV) cavity during stress gated myocardial perfusion imaging (GMPI) is known as a predictor of severe coronary artery disease (CAD) and signifies worse prognosis. To assess predictive and prognostic value of TID of LV cavity using GMPI and clinical outcome in patients treated conservatively or with revascularization. 189 patients out of 2689 were recruited (M:F 127/62, mean age 56±9 years) whose same-day stress GMPI revealed TID ratio (>1.22) with no (sum stress score, SSS 2). Coronary angiography (CA) was performed within 3 months in 125/189 cases who were followed for mean period of 18±4 months for fatal or non-fatal myocardial infraction (MI). CA was positive in 121/125 patients with TID for significant CAD (left anterior descending (LAD) =11, multi vessel disease =110 patients, positive predictive value 95%) and negative for obstructive disease in 4/125 (false-positive cases). 41/121 underwent revascularization within 2 months of CA (Intervention group), and remaining 80/121 were managed conservatively (Non-Intervention group). Overall event rate was 20% (4/16%: fatal/non-fatal MIs). Kaplan-Meier survival curves revealed event-free survival in Intervention and Non-Intervention groups for fatal MI 98/96% (P=0.758), and for non-fatal MI, it was 97/58%, respectively (P=0.042). We conclude that TID is a reliable predictor of multi vessel CAD and is associated with high incidence of non-fatal MIs than fatal MIs. Revascularization (percutaneous coronary intervention (PCI)/coronary artery bypass graft (CABG)) rather than medical treatment should be considered in patients with TID for better clinical outcome. (author)

  15. Cerebral blood flow SPET in transient global amnesia with automated ROI analysis by 3DSRT

    Energy Technology Data Exchange (ETDEWEB)

    Takeuchi, Ryo [Division of Nuclear Medicine, Nishi-Kobe Medical Center, Kohjidai 5-7-1, 651-2273, Nishi-ku, Kobe-City, Hyogo (Japan); Matsuda, Hiroshi [Department of Radiology, National Center Hospital for Mental, Nervous and Muscular Disorders, National Center of Neurology and Psychiatry, Tokyo (Japan); Yoshioka, Katsunori [Daiichi Radioisotope Laboratories, Ltd., Tokyo (Japan); Yonekura, Yoshiharu [Biomedical Imaging Research Center, University of Fukui, Fukui (Japan)

    2004-04-01

    The aim of this study was to determine the areas involved in episodes of transient global amnesia (TGA) by calculation of cerebral blood flow (CBF) using 3DSRT, fully automated ROI analysis software which we recently developed. Technetium-99m l,l-ethyl cysteinate dimer single-photon emission tomography ({sup 99m}Tc-ECD SPET) was performed during and after TGA attacks on eight patients (four men and four women; mean study interval, 34 days). The SPET images were anatomically standardized using SPM99 followed by quantification of 318 constant ROIs, grouped into 12 segments (callosomarginal, precentral, central, parietal, angular, temporal, posterior cerebral, pericallosal, lenticular nucleus, thalamus, hippocampus and cerebellum), in each hemisphere to calculate segmental CBF (sCBF) as the area-weighted mean value for each of the respective 12 segments based on the regional CBF in each ROI. Correlation of the intra- and post-episodic sCBF of each of the 12 segments of the eight patients was estimated by scatter-plot graphical analysis and Pearson's correlation test with Fisher's Z-transformation. For the control, {sup 99m}Tc-ECD SPET was performed on eight subjects (three men and five women) and repeated within 1 month; the correlation between the first and second sCBF values of each of the 12 segments was evaluated in the same way as for patients with TGA. Excellent reproducibility between the two sCBF values was found in all 12 segments of the control subjects. However, a significant correlation between intra- and post-episodic sCBF was not shown in the thalamus or angular segments of TGA patients. The present study was preliminary, but at least suggested that thalamus and angular regions are closely involved in the symptoms of TGA. (orig.)

  16. Cerebral blood flow SPET in transient global amnesia with automated ROI analysis by 3DSRT

    International Nuclear Information System (INIS)

    Takeuchi, Ryo; Matsuda, Hiroshi; Yoshioka, Katsunori; Yonekura, Yoshiharu

    2004-01-01

    The aim of this study was to determine the areas involved in episodes of transient global amnesia (TGA) by calculation of cerebral blood flow (CBF) using 3DSRT, fully automated ROI analysis software which we recently developed. Technetium-99m l,l-ethyl cysteinate dimer single-photon emission tomography ( 99m Tc-ECD SPET) was performed during and after TGA attacks on eight patients (four men and four women; mean study interval, 34 days). The SPET images were anatomically standardized using SPM99 followed by quantification of 318 constant ROIs, grouped into 12 segments (callosomarginal, precentral, central, parietal, angular, temporal, posterior cerebral, pericallosal, lenticular nucleus, thalamus, hippocampus and cerebellum), in each hemisphere to calculate segmental CBF (sCBF) as the area-weighted mean value for each of the respective 12 segments based on the regional CBF in each ROI. Correlation of the intra- and post-episodic sCBF of each of the 12 segments of the eight patients was estimated by scatter-plot graphical analysis and Pearson's correlation test with Fisher's Z-transformation. For the control, 99m Tc-ECD SPET was performed on eight subjects (three men and five women) and repeated within 1 month; the correlation between the first and second sCBF values of each of the 12 segments was evaluated in the same way as for patients with TGA. Excellent reproducibility between the two sCBF values was found in all 12 segments of the control subjects. However, a significant correlation between intra- and post-episodic sCBF was not shown in the thalamus or angular segments of TGA patients. The present study was preliminary, but at least suggested that thalamus and angular regions are closely involved in the symptoms of TGA. (orig.)

  17. Limbic system perfusion in Alzheimer's disease measured by MRI-coregistered HMPAO SPET

    Energy Technology Data Exchange (ETDEWEB)

    Callen, David J.A. [Institute of Medical Science, Research Program in Aging, Imaging, Sunnybrook and Women' s University of Toronto, ON (Canada); Black, Sandra E. [Cognitive Neurology Unit and Research Program in Aging, Sunnybrook and Women' s College Health Sciences Centre, Toronto, ON (Canada); Institute of Medical Science, Research Program in Aging, Imaging, Sunnybrook and Women' s University of Toronto, ON (Canada); Department of Medicine (Neurology), University of Toronto, ON (Canada); Caldwell, Curtis B. [Department of Medical Imaging, Sunnybrook and Women' s College Health Sciences Centre and University of Toronto, CN (Canada)

    2002-07-01

    The goal of this study was to perform a systematic, semi-quantitative analysis of limbic perfusion in patients with Alzheimer's disease (AD) using coregistered single-photon emission tomography (SPET) images aligned to magnetic resonance (MR) images. Limbic perfusion in 40 patients with mild to moderate AD was compared with that of 17 age-, sex-, and education-matched normal controls (NC). HMPAO SPET scans and 3D T1-weighted MR images were acquired for each subject. Structures of the limbic system (i.e. hippocampus, amygdala, anterior thalamus, hypothalamus, mamillary bodies, basal forebrain, septal area and cingulate, orbitofrontal and parahippocampal cortices) were traced on the MR images and transferred to the coregistered SPET scans. Perfusion ratios for all limbic regions were calculated relative to cerebellar perfusion. General linear model multivariate analysis revealed that, overall, limbic structures showed significant hypoperfusion (F=7.802, P<0.00001, {eta}{sup 2}=0.695) in AD patients compared with NC. Greatest differences (d{>=}0.8) were found in the hippocampus, as well as all areas of the cingulate cortex. Significant relative hypoperfusion was also apparent in the parahippocampal cortex, amygdala/entorhinal cortex, septal area and anterior thalamus, all of which showed medium to large effect sizes (d=0.6-0.8). No significant relative perfusion differences were detected in the basal forebrain, hypothalamus, mamillary bodies or orbitofrontal cortex. Logistic regression indicated that posterior cingulate cortex perfusion was able to discriminate AD patients from NC with 93% accuracy (95% sensitivity, 88% specificity). The current results suggest that most, but not all, limbic structures show significant relative hypoperfusion in AD. These findings validate previous post-mortem studies and could be useful in improving diagnostic accuracy, monitoring disease progression and evaluating potential treatment strategies in AD. (orig.)

  18. USPIO-enhanced 3D-cine self-gated cardiac MRI based on a stack-of-stars golden angle short echo time sequence: Application on mice with acute myocardial infarction.

    Science.gov (United States)

    Trotier, Aurélien J; Castets, Charles R; Lefrançois, William; Ribot, Emeline J; Franconi, Jean-Michel; Thiaudière, Eric; Miraux, Sylvain

    2016-08-01

    To develop and assess a 3D-cine self-gated method for cardiac imaging of murine models. A 3D stack-of-stars (SOS) short echo time (STE) sequence with a navigator echo was performed at 7T on healthy mice (n = 4) and mice with acute myocardial infarction (MI) (n = 4) injected with ultrasmall superparamagnetic iron oxide (USPIO) nanoparticles. In all, 402 spokes were acquired per stack with the incremental or the golden angle method using an angle increment of (360/402)° or 222.48°, respectively. A cylindrical k-space was filled and repeated with a maximum number of repetitions (NR) of 10. 3D cine cardiac images at 156 μm resolution were reconstructed retrospectively and compared for the two methods in terms of contrast-to-noise ratio (CNR). The golden angle images were also reconstructed with NR = 10, 6, and 3, to assess cardiac functional parameters (ejection fraction, EF) on both animal models. The combination of 3D SOS-STE and USPIO injection allowed us to optimize the identification of cardiac peaks on navigator signal and generate high CNR between blood and myocardium (15.3 ± 1.0). The golden angle method resulted in a more homogeneous distribution of the spokes inside a stack (P cine images could be obtained without electrocardiogram or respiratory gating in mice. It allows precise measurement of cardiac functional parameters even on MI mice. J. Magn. Reson. Imaging 2016;44:355-365. © 2016 Wiley Periodicals, Inc.

  19. Research of predictive factors for cardiac resynchronization therapy: a prospective study comparing data from phase-analysis of gated myocardial perfusion single-photon computed tomography and echocardiography : Trying to anticipate response to CRT.

    Science.gov (United States)

    Gendre, Rémy; Lairez, O; Mondoly, P; Duparc, A; Carrié, D; Galinier, M; Berry, I; Cognet, T

    2017-04-01

    Cardiac resynchronization therapy (CRT) reduces morbidity and mortality in chronic systolic heart failure. About 20% of implanted patients are considered as "non-responders". This study aimed to evaluate gated myocardial perfusion single-photon emission computed tomography (GMPS) phase parameters as compared to echocardiography in the assessment of predictors for response to CRT before and after CRT activation. Forty-two patients were prospectively included during 15 months. A single injection of 99m Tc-tetrofosmin was used to acquire GMPS phase pre- and post-CRT activation. Indicators of positive CRT response were improvement of functional status and 15% reduction in left ventricular end-systolic volume at 3 months. Phase parameters at baseline were similar in the two groups with no influence of perfusion data. Phase parameters after CRT activation were significantly improved in the responders' group (Δ Bandwidth -19° ± 24° vs. 13° ± 31°, p = 0.001; Δ SD -20° ± 30° vs. 26° ± 46°, p = 0.001; Δ Entropy -11 ± 12 vs. 2 ± 6%, p = 0.001). Feasibility and reproducibility were higher for GMPS. Acute phase modifications after CRT activation may predict response to CRT immediately after implantation, but not at baseline, even when adjusted to perfusion data.

  20. Use of technetium-99m hexamethylpropylene amine oxime SPET for the study of cerebral blood flow reactivity after acetazolamide infusion in patients with Behcet's disease

    Energy Technology Data Exchange (ETDEWEB)

    Pupi, A.; Sestini, S.; Cristofaro, M.T.R. de; Meldolesi, U. [Department of Clinical Physiopathology, Nuclear Medicine Section, Careggi Hospital, University of Florence, Florence (Italy); Emmi, L.; Marchione, T.; Salvati, G.; Li Gobbi, F. [Department of Clinical Immuno-allergology, Careggi Hospital, University of Florence, Florence (Italy); Massacesi, L. [Departments of Neurological and Psychiatrical Science, Careggi Hospital, University of Florence, Florence (Italy)

    2000-06-01

    The purpose of this study was to characterise the nature of the baseline perfusion defects found in patients with Behcet's disease using hexamethylpropylene amine oxime single-photon emission tomography in conjunction with acetazolamide test (Acz SPET). Eleven patients underwent both baseline and Acz SPET. Regions of interest (ROIs) were drawn on the areas with decreased perfusion (D-ROI) and, in the same section, on areas with normal perfusion (N-ROI). The ROIs were then repositioned on the corresponding section on Acz SPET. The mean ROI counts were then transformed into a perfusion index value (PIV) with reference to the global brain counts. In total we found 24 D-ROIs (17 in the cortical and 7 in subcortical grey matter). The influence of Acz infusion was selectively registered in the D-ROIs, where PIVs changed from 1.23{+-}0.17 (baseline SPET) to 1.63{+-}0.23 (Acz SPET) (P<0.001). No significant difference was seen in the N-ROIs (1.46{+-}0.21 and 1.40{+-}0.17, respectively, on baseline SPET and Acz SPET). Our results demonstrate that Acz infusion increases the regional cerebral blood flow within baseline grey matter perfusion defects. This finding suggests that baseline perfusion abnormalities could reflect a disconnection rather than local vasculitic involvement. (orig.)

  1. Differences in 99mTc-HMPAO brain SPET perfusion imaging between Tourette's syndrome and chronic tic disorder in children

    International Nuclear Information System (INIS)

    Chiu, N.-T.; Lee, B.-F.; Chang, Y.-C.; Huang, C.-C.; Wang, S.-T.

    2001-01-01

    Early differential diagnosis between Tourette's syndrome and chronic tic disorder is difficult but important because both the outcome and the treatment of these two childhood-onset diseases are distinct. We assessed the sensitivity and specificity of brain single-photon emission tomography (SPET) perfusion imaging in distinguishing the two diseases, and characterized their different cerebral perfusion patterns. Twenty-seven children with Tourette's syndrome and 11 with chronic tic disorder (mean age 9.5 and 8.6 years, respectively) underwent brain SPET with technetium-99m hexamethylpropylene amine oxime (HMPAO). Visual interpretation and semi-quantitative analysis of SPET images were performed. On visual interpretation, 22 of 27 (82%) of the Tourette's syndrome group had lesions characterized by decreased perfusion. The left hemisphere was more frequently involved. None of the children with chronic tic disorder had a visible abnormality. Semi-quantitative analysis showed that, compared with children with chronic tic disorder, children with Tourette's syndrome had significantly lower perfusion in the left lateral temporal area and asymmetric perfusion in the dorsolateral frontal, lateral and medial temporal areas. In conclusion, using the visual approach, brain SPET perfusion imaging is sensitive and specific in differentiating Tourette's syndrome and chronic tic disorder. The perfusion difference between the two groups, demonstrated by semi-quantitative analysis, may be related more to the co-morbidity in Tourette's syndrome than to tics per se. (orig.)

  2. Cobalt-57 as a SPET tracer in the visualization of ischaemic brain damage in patients with middle cerebral artery stroke

    NARCIS (Netherlands)

    Stevens, H; Knollema, S; Piers, DA; Van de Wiele, C; Jansen, HML; De Jager, AEJ; De Reuck, J; Dierckx, RA; Korf, J

    In PET studies we have shown the usefulness of cobalt radionuclides for the visualization and quantification of ischaemic damage in stroke. In the present study, we explored Co-57(2+) as a SPET tracer. Uptake of radioactivity was estimated by using a cobalt enhancement ratio defined as the ratio of

  3. Feasibility and diagnostic accuracy of Ecg-gated SPECT myocardial perfusion imaging by a two-hour protocol: The Myofast study;Faisabilite et precision diagnostique d'un protocole de scintigraphie myocardique synchronisee a l'ECG en deux heures: l'etude Myofast

    Energy Technology Data Exchange (ETDEWEB)

    Dunet, V.; Costo, S.; Sabatier, R.; Grollier, G.; Bouvard, G.; Agostini, D. [CHU Cote-de-Nacre, Service de medecine nucleaire, 14 - Caen (France)

    2010-04-15

    Aim of the study: To assess the feasibility of early stress and rest myocardial perfusion and function study using a fast {sup 99m}Tc-tetrofosmin gated-SPECT protocol in patients with known coronary artery disease. Materials and methods: Forty-three patients (pts) (37 M, 6 F, mean age 63.8 +- 9.8 years) underwent a {sup 99m}Tc-Tetrofosmin gated-SPECT (Axis Picker-Philips) myocardial study and a coronary angiography (C.A.) within 3 months. Images were acquired (LEHR, eight bins, 40 sec per image) after injection of {sup 99m}Tc-tetrofosmin (200 to 380 MBq) early (15 min) post-stress (36 dipyridamole, two dobutamine and five ergo-metric stress), and at rest after {sup 99m}Tc-tetrofosmin reinjection (600 to 1150 MBq), in a total time not exceeding 2 hours. Processing was performed with Q.G.S. software using the 17-segment model. Pathological study was defined as a summed difference score (SDS) greater than or equal to 4 4, a fixed defect with summed rest score greater than or equal to 4 and/or L.V. dysfunction defined as myocardial stunning (variation between stress and rest L.V.E.F. greater than or equal to 4 5%), stress L.V.E.F. less than or equal to 45% or rest L.V.E.F. less than or equal to 40%. Results were compared with C.A., and stenosis greater than or equal to 4 50% was considered as significant. Results: For 100% the quality of SPECT imaging was good or excellent. For six patients gating was impossible because of arrhythmia. The overall sensitivity, specificity and accuracy were 95%, 50%, and 91%, respectively. The concordance between gated SPECT and C.A. was moderate (kappa = 0.45, S.E. = 0.15). Interestingly, early-gated acquisition permitted to underline left ventricular dysfunction in 11 cases (30%), of whom eight had poly vascular disease. Stunning was detected in six of 37 cases (16%), of whom six had poly vascular disease. Conclusion: A one-day two-hour {sup 99m}Tc-tetrofosmin gated-SPECT protocol to assess left ventricular perfusion and function is

  4. Surveillance study for creating the national clinical database relating to ECG-gated myocardial perfusion SPECT of asymptomatic ischemic heart disease in patients with type-2 diabetes mellitus. J-ACCESS 2 study design

    International Nuclear Information System (INIS)

    Kusuoka, Hideo; Yamasaki, Yoshimitsu; Izumi, Tohru; Kashiwagi, Atsunori; Kawamori, Ryuzo; Shimamoto, Kazuaki; Yamada, Nobuhiro; Nishimura, Tsunehiko

    2008-01-01

    Diabetes mellitus is an independent risk factor for acute myocardial infarction. Thus, a surveillance study was conducted as part of studies to create a national database related to electrocardiogram (ECG)-gated myocardial perfusion single-photon emission computed tomography (SPECT) of ischemic heart disease. Single-photon emission computed tomography was conducted in patients with type 2 diabetes mellitus and their prognoses will be followed for 3 years, stratified by patients' clinical background and SPECT findings. A total of 513 patients from 50 institutions were enrolled in this study, 297 of whom were men (age 66.2±0.4 years, mean±standard error of the mean (SEM)) and 261 women (age 67.8±0.5 years). They have a history of retinopathy (25.3%), neuropathy (19.9%), cerebrovascular disorder, chronic obstructive pulmonary disease, and photocoagulation. Major risk factors for present disease were hypertension (82.3%) and hyperlipidemia (79.7%). In 244 patients (129 men and 115 women), body mass index (BMI) was 25 or more. Fifty-two of them (10.1%) underwent coronary angiography; of these, 26 (50.0%) had no coronary artery lesions with 75% or more stenosis, and only 1 (1.9%) had a left main trunk with 50% or more stenosis. An overwhelming majority of patients (94.3%) underwent SPECT imaging by a 1-day stress-followed-by-rest procedure. Stress procedure was exercise in most (70.8%) patients, followed by dipyridamole infusion in 14.6%, adenosine infusion in 6.6%, and adenosine triphosphate infusion in 5.7%. Endpoint of stress examination was most often fatigue in lower limbs (40.7%), followed by completion of pharmacological stress protocol (28.7%), and achievement of target heart rate (26.3%). The largest number of patients (198, 38.6%) received 99m Tc-tetrofosmin at an initial dosage of 200-300 MBq (mean 331±3 MBq) followed by a second dosage of 700-800 MBq (mean 748±8 MBq). Among them, 491 (95.7%) received some kind of therapeutic drug: hypoglycemic drugs were

  5. Linear gate

    International Nuclear Information System (INIS)

    Suwono.

    1978-01-01

    A linear gate providing a variable gate duration from 0,40μsec to 4μsec was developed. The electronic circuity consists of a linear circuit and an enable circuit. The input signal can be either unipolar or bipolar. If the input signal is bipolar, the negative portion will be filtered. The operation of the linear gate is controlled by the application of a positive enable pulse. (author)

  6. Clinical impact of diagnostic SPET investigations with a dopamine re-uptake ligand

    DEFF Research Database (Denmark)

    Løkkegaard, Annemette; Werdelin, Lene M; Friberg, Lars

    2002-01-01

    The diagnosis of Parkinson's disease is based on clinical features with pathological verification. However, autopsy has been found to confirm a specialist diagnosis in only about 75% of cases. Especially early in the course of the disease, the clinical diagnosis can be difficult. Imaging...... of presynaptic dopamine transporters (DAT receptors) has provided a possible diagnostic probe in the evaluation of Parkinson's disease. The cocaine analogue [(123)I]-2-beta-carboxymethoxy-3-beta(4-iodophenyl)tropane ([(123)I]-beta-CIT) is one of several radioligands that have been developed for single...... referred to [(123)I]-beta-CIT SPET from the neurological department, Bispebjerg Hospital. In 58 subjects the scans revealed altered tracer uptake consistent with Parkinson's disease, progressive supranuclear palsy and multiple system atrophy. A significant change in the management or treatment because...

  7. Accuracy of technetium-99m tetrofosmin myocardial perfusion imaging in the detection of spontaneous recanalization in patients with acute anterior myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Hamada, Shinichi; Nakamura, Seishi; Nishiue, Takashi; Watanabe, Junko; Hatada, Kengo; Miyoshi, Hironori; Iwasaka, Toshiji [Cardiovascular Center, Kansai Medical University, Osaka (Japan); Sugiura, Tetsuro [Dept. of Clinical Laboratory Medicine, Kochi Medical School, Kochi (Japan); Baden, Masato [Division of Cardiology, Takarazuka Hospital, Hyogo (Japan)

    2001-03-01

    To avoid the haemorrhagic risk of unnecessary thrombolysis in acute myocardial infarction (MI), early and precise diagnosis of spontaneous recanalization (SR) of the infarct-related artery is required. To clarify the accuracy of technetium-99m tetrofosmin myocardial single-photon emission tomography (SPET) in the detection of SR in patients with acute anterior MI, electrocardiography (ECG), echocardiography and {sup 99m}Tc-tetrofosmin SPET imaging were performed in 49 patients with acute anterior MI before emergency coronary angiography. Defect score was calculated as the sum of the perfusion defects of each segment: from 3 (complete defect) to 0 (normal perfusion). Echocardiographic asynergic score (the sum of asynergic grades) and the greatest ST elevation of the 12-lead ECG on admission were also measured. SR was defined as Thrombolysis in Myocardial Infarction (TIMI) grade 3 flow on emergency coronary angiography. Defect score in 11 patients with SR (9.2{+-}3.7) was significantly lower than that in 38 patients without SR (18.5{+-}5.0) (P<0.001), whereas there were no significant differences in asynergic score and ST elevation between the two groups. From the receiver operating characteristic curves, the optimal cut-off points of defect score, asynergic score and ST elevation for the detection of SR were calculated to be 12, 13 and 3.5, respectively. The sensitivity and specificity of the scintigraphic defect score (91% and 89%) were significantly higher than those of the asynergic score (64% and 68%) and ST elevation (73% and 71%). Thus, {sup 99m}Tc-tetrofosmin SPET imaging on admission is a very accurate method for the detection of SR in patients with acute anterior MI. (orig.)

  8. Avaliação da perfusão e função miocárdicas em vítimas de escorpionismo utilizando o Gated-SPECT Evaluación de la perfusión y función miocárdicas en víctimas de escorpionismo utilizando el Gated-SPECT Assessment of myocardial perfusion and function in victims of scorpion envenomation using Gated-SPECT

    Directory of Open Access Journals (Sweden)

    Alexandre Baldini de Figueiredo

    2010-04-01

    are the major causes of death of patients with scorpion envenomation, whose pathophysiological mechanism remains controversial. OBJECTIVE: To investigate the correlation between myocardial perfusion abnormalities and left ventricular contractile function in victims of scorpion envenomation. METHODS: Fifteen patients underwent ECG-gated myocardial perfusion scintigraphy (gated SPECT within 72 hours of, and 15 days after scorpion envenomation. Images were analyzed by means of a semi-quantitative visual perfusion score (0 = normal, 4 = absent and motion score (0 = normal, 4 = akinesia, using the 17-segment model. Summed perfusion (SPS and summed motion (SMS scores were calculated for each patient. Ejection fraction (LVEF was calculated by a commercially available software. RESULTS: At baseline, 12 out of the 15 patients presented abnormal myocardial perfusion and contractility. Mean values of SPS, SMS and LVEF were 12.5 ± 7.3, 17.0 ± 12.8, and 44.6 ± 16.0%, respectively. A positive correlation between SPS and SMS (r = 0.68; p = 0.005 and negative correlation between SPS and LVEF (r = -0.75; p = 0.0021 were found. The follow-up studies showed recovery of global contractility (LVEF of 68.9 ± 9.5, p = 0.0002, segmental contractility (SMS of 2.6 ± 3.1, p = 0.0009 and perfusion (SPS of 3.7 ± 3.3, p = 0.0003. Improvement of LVEF correlated positively with improvement of SPS (r = 0.72; p = 0.0035. CONCLUSIONS: Myocardial perfusion abnormalities are common in scorpion envenomation and correlate topographically with the contractile dysfunction. Recovery of contractility correlates with reversibility of perfusion defects. These findings suggest the participation of myocardial perfusion abnormalities in the pathophysiology of this form of acute ventricular failure. (Arq Bras Cardiol 2010;94(4: 418-425

  9. Validation of quantitative brain dopamine D2 receptor imaging with a conventional single-head SPET camera

    International Nuclear Information System (INIS)

    Nikkinen, P.; Liewendahl, K.; Savolainen, S.; Launes, J.

    1993-01-01

    Phantom measurements were performed with a conventional single-head single-photon emission tomography (SPET) camera in order to validate the relevance of the basal ganglia/frontal cortex iodine-123 iodobenzamide (IBZM) uptake ratios measured in patients. Inside a cylindrical phantom (diameter 22 cm), two cylinders with a diameter of 3.3 cm were inserted. The activity concentrations of the cylinders ranged from 6.0 to 22.6 kBq/ml and the cylinder/background activity ratios varied from 1.4 to 3.8. From reconstructed SPET images the cylinder/background activity ratios were calculated using three different regions of interest (ROIs). A linear relationship between the measured activity ratio and the true activity ratio was obtained. In patient studies, basal ganglia/frontal cortex IBZM uptake ratios determined from the reconstructed slices using attentuation correction prior to reconstruction were 1.30 ±0.03 in idiopathic Parkinson's disease (n = 9), 1,33 ±0.09 in infantile and juvenile neuronal ceroid lipofuscinosis (n = 7) and 1.34 ±0.05 in narcolepsy (n = 8). Patients with Huntington's disease had significantly lower ratios (1.09 ±0.04, n = 5). The corrected basal ganglia/frontal cortex ratios, determined using linear regression, were about 80 % higher. The use of dual-window scatter correction increased the measured ratios by about 10 %. Although comprehensive correction methods can further improve the resolution in SPET images, the resolution of the SPET system used by us (1.5 - 2 cm) will determine what is achievable in basal ganglia D2 receptor imaging. (orig.)

  10. Role of 123I-IMP SPET in the early diagnosis of borderline chronic hydrocephalus after aneurysmal subarachnoid haemorrhage

    International Nuclear Information System (INIS)

    Ohkuma, Hiroki; Tanaka, Masahiko; Suzuki, Shigeharu; Kondoh, Izumi

    2000-01-01

    Chronic hydrocephalus after aneurysmal subarachnoid haemorrhage (SAH) is easily diagnosed in most cases. However, the diagnosis is sometimes difficult in borderline cases, in which (a) pathognomonic clinical deterioration due to hydrocephalus is masked by the neurological deficits caused in the acute stage of SAH and (b) ventricular enlargement is not so marked on CT scan. The purpose of this study was to investigate whether or not iodine-123 labelled N-isopropyl-p-iodoamphetamine ( 123 I-IMP) single-photon emission tomography (SPET) is of value for the early diagnosis of borderline chronic hydrocephalus after SAH. Fifteen patients who met the criteria of borderline chronic hydrocephalus were selected for the study, and underwent a shunt operation. The patients were divided into a shunt-effective group and a shunt-ineffective group according to neurological improvement after the shunt operation. 123 I-IMP SPET was performed in the acute stage of SAH, within 1 week before the shunt operation, and 2 weeks after the shunt operation. Regional cerebral blood flow was estimated by the 123 I-IMP autoradiographic method. Pre-shunting periventricular low-perfusion areas showed statistically significant differences between the two groups (P 123 I-IMP SPET can be used for both the early diagnosis of borderline chronic hydrocephalus after SAH and the prediction of shunt effectiveness. (orig.)

  11. MiR-223-3p as a Novel MicroRNA Regulator of Expression of Voltage-Gated K+ Channel Kv4.2 in Acute Myocardial Infarction

    Directory of Open Access Journals (Sweden)

    Xue Liu

    2016-06-01

    Full Text Available Background/Aims: Acute myocardial infarction (AMI is a devastating cardiovascular disease with a high rate of morbidity and mortality, partly due to enhanced arrhythmogenicity. MicroRNAs (miRNAs have been shown to participate in the regulation of cardiac ion channels and the associated arrhythmias. The purpose of this study was to test our hypothesis that miR-223-3p contributes to the electrical disorders in AMI via modulating KCND2, the gene encoding voltage-gated channel Kv4.2 that carries transient outward K+ current Ito. Methods: AMI model was established in male Sprague-Dawley (SD rats by left anterior descending artery (LAD ligation. Evans blue and TTC staining was used to measure infarct area. Ito was recorded in isolated ventricular cardiomyocytes or cultured neonatal rat ventricular cells (NRVCs by whole-cell patch-clamp techniques. Western blot analysis was employed to detect the protein level of Kv4.2 and real-time RT-PCR to determine the transcript level of miR-223-3p. Luciferase assay was used to examine the interaction between miR-223-3p and KCND2 in cultured NRVCs. Results: Expression of miR-223-3p was remarkably upregulated in AMI relative to sham control rats. On the contrary, the protein level of Kv4.2 and Ito density were significantly decreased in AMI. Consistently, transfection of miR-223-3p mimic markedly reduced Kv4.2 protein level and Ito current in cultured NRVCs. Co-transfection of AMO-223-3p (an antisense inhibitor of miR-223-3p reversed the repressive effect of miR-223-3p. Luciferase assay showed that miR-223-3p, but not the negative control, substantially suppressed the luciferase activity, confirming the direct binding of miR-223-3p to the seed site within the KCND2 sequence. Finally, direct intramuscular injection of AMO-223-3p into the ischemic myocardium to knockdown endogenous miR-223-3p decreased the propensity of ischemic arrhythmias. Conclusions: Upregulation of miR-223-3p in AMI repressed the expression of

  12. Selvester QRS score and total perfusion deficit calculated by quantitative gated single-photon emission computed tomography in patients with prior anterior myocardial infarction in the coronary intervention era.

    Science.gov (United States)

    Kurisu, Satoshi; Shimonaga, Takashi; Ikenaga, Hiroki; Watanabe, Noriaki; Higaki, Tadanao; Ishibashi, Ken; Dohi, Yoshihiro; Fukuda, Yukihiro; Kihara, Yasuki

    2017-04-01

    Selvester QRS scoring system has an advantage of being inexpensive and easily accessible for estimating myocardial infarct (MI) size. We assessed the correlation and agreement between QRS score and total perfusion deficit (TPD) calculated by quantitative gated single-photon emission computed tomography (QGS) in patients with prior anterior MI undergoing coronary intervention. Sixty-six patients with prior anterior MI and 66 age- and sex-matched control subjects were enrolled. QRS score was obtained using a 50-criteria and 31-point system. QRS score was significantly higher in patients with prior anterior MI than control subjects (12.8 ± 8.9 vs 1.1 ± 2.7 %, p < 0.001). In overall patients (n = 132), QRS score was correlated well with TPD (r = 0.81, p < 0.001). This good correlation was found even in patients with TPD ≤40 % (n = 126) or in patients with TPD ≤30 % (n = 117). In overall patients, MI size estimated by QRS score was 7.0 ± 8.8 %, which was significantly smaller than TPD, 11.4 ± 14.0 % (p < 0.001). Bland-Altman plot showed that there was an increasing difference between QRS score and TPD with increasing MI size. When Blant-Altman plots were applied to patients with TPD ≤40 % and further in patients with TPD ≤30 %, the difference between QRS score and TPD became smaller, and the agreement became better. In overall patients, QRS score was correlated well with QGS measurements, such as end-diastolic volume (r = 0.62, p < 0.001), end-systolic volume (r = 0.67, p < 0.001), or ejection fraction (r = -0.73, p < 0.001). Our results suggest that QRS score reflects TPD well in patients with prior anterior MI, whose TPD is less than approximately 30 % even in the coronary intervention era.

  13. Myocardial contusion

    Science.gov (United States)

    ... 000202.htm Myocardial contusion To use the sharing features on this page, please enable JavaScript. Myocardial contusion ... Wear a seat belt when driving. Choose a car with air bags. Take steps to ensure safety when working at heights. Alternative Names Blunt myocardial ...

  14. Should scatter be corrected in both transmission and emission data for accurate quantitation in cardiac SPET?

    International Nuclear Information System (INIS)

    Fakhri, G.E.; Buvat, I.; Todd-Pokropek, A.; Benali, H.; Almeida, P.; Bendriem, B.

    2000-01-01

    Ideally, reliable quantitation in single-photon emission tomography (SPET) requires both emission and transmission data to be scatter free. Although scatter in emission data has been extensively studied, it is not well known how scatter in transmission data affects relative and absolute quantitation in reconstructed images. We studied SPET quantitative accuracy for different amounts of scatter in emission and transmission data using a Utah phantom and a cardiac Data Spectrum phantom including different attenuating media. Acquisitions over 180 were considered and three projection sets were derived: 20% images and Jaszczak and triple-energy-window scatter-corrected projections. Transmission data were acquired using gadolinium-153 line sources in a 90-110 keV window using a narrow or wide scanning window. The transmission scans were performed either simultaneously with the emission acquisition or 24 h later. Transmission maps were reconstructed using filtered backprojection and μ values were linearly scaled from 100 to 140 keV. Attenuation-corrected images were reconstructed using a conjugate gradient minimal residual algorithm. The μ value underestimation varied between 4% with a narrow transmission window in soft tissue and 22% with a wide window in a material simulating bone. Scatter in the emission and transmission data had little effect on the uniformity of activity distribution in the left ventricle wall and in a uniformly hot compartment of the Utah phantom. Correcting the transmission data for scatter had no impact on contrast between a hot and a cold region or on signal-to-noise ratio (SNR) in regions with uniform activity distribution, while correcting the emission data for scatter improved contrast and reduced SNR. For absolute quantitation, the most accurate results (bias <4% in both phantoms) were obtained when reducing scatter in both emission and transmission data. In conclusion, trying to obtain the same amount of scatter in emission and transmission

  15. Does intravenous Δ9-tetrahydrocannabinol increase dopamine release? A SPET study.

    Science.gov (United States)

    Barkus, Emma; Morrison, Paul D; Vuletic, D; Dickson, John C; Ell, Peter J; Pilowsky, Lyn S; Brenneisen, Rudolf; Holt, David W; Powell, John; Kapur, Shitij; Murray, Robin M

    2011-11-01

    Intravenous (IV) Δ9-tetrahydrocannabinol (THC) induces transient psychotic symptoms in healthy subjects and in schizophrenic patients, but the psychotomimetic mechanism is unknown. One possibility is that THC stimulates dopamine (DA) release in the striatum. In this study we tested whether IV THC led to an increase in striatal DA release compared to placebo. We also investigated whether DA release and positive psychotic symptoms were related. Eleven healthy male volunteers completed two 123I-iodobenzamide ([123I]IBZM) single photon emission tomography (SPET) sessions and received IV THC (2.5 mg) or placebo in a randomized counterbalanced order, under double-blind conditions. Analysable data were obtained from nine participants. The Positive and Negative Syndrome Scale (PANSS) was used to rate psychotomimetic effects. Striatal binding index values were calculated using the occipital cortex as a reference region. Both the PANSS positive and general symptoms increased significantly at 30 min following IV THC. There were no significant differences in binding index in the caudate or putamen under THC compared to placebo conditions. Positive psychotic symptoms and DA release were unrelated. THC did not lead to a significant increase in DA release even though the dose was sufficient for participants to have psychotic symptoms. These findings do not support a central role for striatal DA in THC-elicited psychosis.

  16. Accelerated median root prior reconstruction for pinhole single-photon emission tomography (SPET)

    Energy Technology Data Exchange (ETDEWEB)

    Sohlberg, Antti [Department of Clinical Physiology and Nuclear Medicine, Kuopio University Hospital, PO Box 1777 FIN-70211, Kuopio (Finland); Ruotsalainen, Ulla [Institute of Signal Processing, DMI, Tampere University of Technology, PO Box 553 FIN-33101, Tampere (Finland); Watabe, Hiroshi [National Cardiovascular Center Research Institute, 5-7-1 Fujisihro-dai, Suita City, Osaka 565-8565 (Japan); Iida, Hidehiro [National Cardiovascular Center Research Institute, 5-7-1 Fujisihro-dai, Suita City, Osaka 565-8565 (Japan); Kuikka, Jyrki T [Department of Clinical Physiology and Nuclear Medicine, Kuopio University Hospital, PO Box 1777 FIN-70211, Kuopio (Finland)

    2003-07-07

    Pinhole collimation can be used to improve spatial resolution in SPET. However, the resolution improvement is achieved at the cost of reduced sensitivity, which leads to projection images with poor statistics. Images reconstructed from these projections using the maximum likelihood expectation maximization (ML-EM) algorithms, which have been used to reduce the artefacts generated by the filtered backprojection (FBP) based reconstruction, suffer from noise/bias trade-off: noise contaminates the images at high iteration numbers, whereas early abortion of the algorithm produces images that are excessively smooth and biased towards the initial estimate of the algorithm. To limit the noise accumulation we propose the use of the pinhole median root prior (PH-MRP) reconstruction algorithm. MRP is a Bayesian reconstruction method that has already been used in PET imaging and shown to possess good noise reduction and edge preservation properties. In this study the PH-MRP algorithm was accelerated with the ordered subsets (OS) procedure and compared to the FBP, OS-EM and conventional Bayesian reconstruction methods in terms of noise reduction, quantitative accuracy, edge preservation and visual quality. The results showed that the accelerated PH-MRP algorithm was very robust. It provided visually pleasing images with lower noise level than the FBP or OS-EM and with smaller bias and sharper edges than the conventional Bayesian methods.

  17. Optimized cervical spine bone SPET for detection of facet joint injury after whiplash injury

    International Nuclear Information System (INIS)

    Cardaci, G.T.; Bower, G.D.; Taylor, J.

    1999-01-01

    Full text: The most frequent origin for chronic cervical pain in patients with a remote history of whiplash injury is the cervical facet joints. Exact localization of facet joint injury is difficult and currently advocated methods include multiple invasive diagnostic injections. Optimization of 99 Tc m -HDP cervical SPET (CSPET) to accurately localize facet joint pathology was attempted and the results correlated with clinical localization relying on focal joint tenderness and passive movement methods. Imaging was performed on a dual-headed gamma camera system using an elliptical orbit over 360 deg. The patient's neck was flexed to eliminate the cervical lordosis. Reconstructed CSPET images were reorientated into the long axis of the vertebral bodies. CSPET studies were independently scored by two observers blinded to the clinical and other imaging information and correlated with clinical localization and response to radiofrequency ablation. 54 patients have been studied using this technique in a prospective study. Early patient follow-up data will be presented. CSPET was felt to be clinically useful by pain therapists in targeting treatment

  18. Labelling and evaluation of new stabilised neurotensin (8-13) analogues for SPET

    International Nuclear Information System (INIS)

    Chavatte, K.; Terriere, D.; Jeannin, L.

    1998-01-01

    Neurotensin (8-13) analogues were biologically stabilised by replacement of the peptide bond between amino acids 8 and 9 by the reduced ψ(CH 2 -NH) isostere. DTPA analogues for In-111 labelling and 2-bromo-phenyl-acetyl analogues for radioiodination, showed receptor affinities in the low nanomolar range in combination with a biological half live in human plasma up to 275 minutes. Biodistribution studies in male Wistar rats of metabolically stabilised and non-stabilised 111 In-DTPA-NT(8-13) analogues showed a major clearance from the blood through the kidneys. 125 I-labelled Neurotensin (8-13) analogues showed accumulation up to 2.2% of the injected dose per g tissue in the liver which might be an important disadvantage when diagnosis of tumours in the gut is aimed. It is strongly suggested that stabilised neurotensin (8-13) analogues whether labelled with In-111, I-123 and the near future with Tc-99m, may act as new potential peptidergic radiopharmaceuticals for SPET diagnosis of different NT-receptor positive tumours like non-endocrine pancreas carcinoma, small cell lung carcinoma or colon adeno carcinoma. It is enticing to speculate that metabolically stabilised Neurotensin (8-13) analogues labelled with an appropriate isotope might be useful in therapy of different human cancers. (author)

  19. Gated equilibrium bloodpool scintigraphy

    International Nuclear Information System (INIS)

    Reinders Folmer, S.C.C.

    1981-01-01

    This thesis deals with the clinical applications of gated equilibrium bloodpool scintigraphy, performed with either a gamma camera or a portable detector system, the nuclear stethoscope. The main goal has been to define the value and limitations of noninvasive measurements of left ventricular ejection fraction as a parameter of cardiac performance in various disease states, both for diagnostic purposes as well as during follow-up after medical or surgical intervention. Secondly, it was attempted to extend the use of the equilibrium bloodpool techniques beyond the calculation of ejection fraction alone by considering the feasibility to determine ventricular volumes and by including the possibility of quantifying valvular regurgitation. In both cases, it has been tried to broaden the perspective of the observations by comparing them with results of other, invasive and non-invasive, procedures, in particular cardiac catheterization, M-mode echocardiography and myocardial perfusion scintigraphy. (Auth.)

  20. Evaluation of the mutual information cost function for registration of SPET and MRI images of the brain

    International Nuclear Information System (INIS)

    Taleb, M.; McKay, E.

    1999-01-01

    Full text: Any strategy for image registration requires some method (a cost function) by which two images may be compared The mutual information (MI) between images is one such cost function. MI measures the structural similarity between pairs of gray-scale images and performs cross-modality image registration with minimal image pre-processing. This project compares the performance of MI vs the sum of absolute differences (SAD) 'gold standard' in monomodality image registration problems. It also examines the precision of cross-modality registration based on MI, using a human observer to decide whether registration is accurate. Thirteen paired brain SPET scans were registered using SAD as a cost function. Registration was repeated using MI and differences from the SAD results were recorded. Ten paired MRI and SPET brain scans registered using the MI cost function. Registration was repeated three times for each pair, varying the SPET position or orientation each time. Comparing MI to SAD, the median values of translation error were 2.85, 4.63 and 2.56 mm in the x, y and z axis and 0.5 j , 1.1 j and 1.0 j around the x, y and z axis respectively. For the cross-modality problems, the mean standard deviation (MSD) observed in x, y and z positioning was 0.18, 0.28 and 0.16 mm respectively. The MSD of orientation was 5.35 j , 1.95 j and 2.48 j around the x, y and z axis respectively. MI performed as well as SAD for monomodality registration. Unlike SAD, MI is also useful for cross-modality image registration tasks, producing visually acceptable results with minimal preprocessing

  1. Dopamine transporter density of basal ganglia assessed with [123I]IPT SPET in obsessive-compulsive disorder

    International Nuclear Information System (INIS)

    Kim, Chan-Hyung; Cheon, Keun-Ah; Lee, Hong-Shick; Koo, Min-Seong; Ryu, Young-Hoon; Lee, Jong-Doo

    2003-01-01

    It has been suggested that dopamine, as well as serotonin, is associated with the pathophysiology of obsessive-compulsive disorder (OCD). Thus, many studies have been performed on brain regions associated with dopamine in patients with OCD. In the present study, we investigated the DAT density of the basal ganglia using iodine-123 labelled N-(3-iodopropen-2-yl)-2β-carbomethoxy-3β-(4-chlorophenyl) tropane ([ 123 I]IPT) single-photon emission tomography (SPET) and evaluated the activity of the presynaptic dopamine function in patients with OCD. Fifteen patients with OCD and 19 normal control adults were included in the study. We performed brain SPET 2 h after the intravenous administration of [ 123 I]IPT and carried out both quantitative and qualitative analyses using the obtained SPET data, which were reconstructed for the assessment of the specific/non-specific dopamine transporter (DAT) binding ratio in the basal ganglia. We then investigated the correlation between the severity scores of OCD symptoms assessed with the Yale-Brown Obsessive-Compulsive Scale (Y-BOCS) and the specific/non-specific DAT binding ratio of the basal ganglia. Compared with normal control adults, patients with OCD showed a significantly increased specific/non-specific DAT binding ratio in the right basal ganglia and a tendency towards an increased specific/non-specific DAT binding ratio in the left basal ganglia. No significant correlation was found between the total scores on the Y-BOCS and the specific/non-specific DAT binding ratio of the basal ganglia. These findings suggest that the dopaminergic neurotransmitter system of the basal ganglia in patients with OCD could be involved in the pathophysiology of OCD. (orig.)

  2. Myocardial Bridging

    Directory of Open Access Journals (Sweden)

    Shi-Min Yuan

    2016-02-01

    Full Text Available Abstract Myocardial bridging is rare. Myocardial bridges are most commonly localized in the middle segment of the left anterior descending coronary artery. The anatomic features of the bridges vary significantly. Alterations of the endothelial morphology and the vasoactive agents impact on the progression of atherosclerosis of myocardial bridging. Patients may present with chest pain, myocardial infarction, arrhythmia and even sudden death. Patients who respond poorly to the medical treatment with β-blockers warrant a surgical intervention. Myotomy is a preferred surgical procedure for the symptomatic patients. Coronary stent deployment has been in limited use due to the unsatisfactory long-term results.

  3. Valor prognóstico da cintilografia miocárdica de perfusão com tetrofosmin marcado com Tecnécio-99m sincronizada com o ciclo cardíaco (" Gated SPECT" na avaliação de pacientes com diabete melito e suspeita clínica de doença arterial coronariana Prognostic value of Tc-99m tetrofosmin myocardial perfusion gated SPECT in patients with diabetes mellitus and suspected coronary artery disease

    Directory of Open Access Journals (Sweden)

    Márcia Maria Sales dos Santos

    2008-01-01

    evaluated. Cardiac death, acute ischemic coronary syndrome, revascularization procedures or encephalic vascular accident were considered future cardiovascular events. The uni- and multivariate analyses were carried out by the multiple logistic regression model (p 3 (p=0.0001 and the number of altered segments > 3 (p=0.0001 were predictors of cardiovascular events. CONCLUSION: The myocardial scintigraphy with gated SPECT adds independent information to the stratification of the risk of future cardiovascular events in patients with DM and suspected coronary artery disease.

  4. Verbal fluency as a prefrontal activation probe: a validation study using 99mTc-ECD brain SPET

    International Nuclear Information System (INIS)

    Audenaert, K.; Brans, B.; Laere, K. van; Versijpt, J.; Dierckx, R.; Lahorte, P.; Heeringen, K. van

    2000-01-01

    This study aimed to investigate the feasibility of brain single-photon emission tomography (SPET) in the letter and category fluency paradigm of the Controlled Oral Word Association (COWA) test in healthy volunteers. Two groups each comprising ten right-handed healthy volunteers were injected twice with 370 MBq technetium-99m ethyl cysteinate dimer following a split-dose paradigm (resting and activation condition). Statistical parametric mapping (SPM96) was used to determine voxelwise significant changes. The letter fluency and the category fluency activation paradigm had a differential brain activation pattern. The posterior part of the left inferior prefrontal cortex (LIPC) was activated in both paradigms, with the category fluency task having an extra activation in the anterior LIPC. In the category fluency task, but not the letter fluency task, an activation in the right inferior prefrontal cortex was found. These findings confirm to a large extent the results of previous functional magnetic resonance imaging and positron emission tomography studies in semantic and phonological activation paradigms. The choice and validity of various methodological characteristics of the experimental design leading to these results are critically discussed. It is concluded that brain SPET activation with the letter fluency and category fluency paradigm under standard neuropsychological conditions in healthy volunteers is both technically and practically feasible. (orig.)

  5. Verbal fluency as a prefrontal activation probe: a validation study using {sup 99m}Tc-ECD brain SPET

    Energy Technology Data Exchange (ETDEWEB)

    Audenaert, K. [Department of Nuclear Medicine, Ghent University Hospital (Belgium); Department of Psychiatry and Medical Psychology, Ghent University Hospital and Ghent University (Belgium); Brans, B.; Laere, K. van; Versijpt, J.; Dierckx, R. [Department of Nuclear Medicine, Ghent University Hospital (Belgium); Lahorte, P. [Department of Nuclear Medicine, Ghent University Hospital (Belgium); Laboratory of Subatomic and Radiation Physics, Ghent University (Belgium); Heeringen, K. van [Department of Psychiatry and Medical Psychology, Ghent University Hospital and Ghent University (Belgium)

    2000-12-01

    This study aimed to investigate the feasibility of brain single-photon emission tomography (SPET) in the letter and category fluency paradigm of the Controlled Oral Word Association (COWA) test in healthy volunteers. Two groups each comprising ten right-handed healthy volunteers were injected twice with 370 MBq technetium-99m ethyl cysteinate dimer following a split-dose paradigm (resting and activation condition). Statistical parametric mapping (SPM96) was used to determine voxelwise significant changes. The letter fluency and the category fluency activation paradigm had a differential brain activation pattern. The posterior part of the left inferior prefrontal cortex (LIPC) was activated in both paradigms, with the category fluency task having an extra activation in the anterior LIPC. In the category fluency task, but not the letter fluency task, an activation in the right inferior prefrontal cortex was found. These findings confirm to a large extent the results of previous functional magnetic resonance imaging and positron emission tomography studies in semantic and phonological activation paradigms. The choice and validity of various methodological characteristics of the experimental design leading to these results are critically discussed. It is concluded that brain SPET activation with the letter fluency and category fluency paradigm under standard neuropsychological conditions in healthy volunteers is both technically and practically feasible. (orig.)

  6. Detection of myocardial viability by means of Single Proton Emission Computed Tomography (Perfused SPECT) dual 201 Tl (rest of 15 minutes, 24 late hours and 24 hours reinjection) and gated-SPECT 99m Tc-SESTAMIBI in effort or stimulation of the coronary reserves

    International Nuclear Information System (INIS)

    Mendoza V, R.

    2004-01-01

    The objective of this work was to determine if the images of SPECT 201 TI in rest of 15 minutes, 24 late hours and Gated-SPECT 99m Tc-SESTAMIBI in effort or stimulation of coronary reservation correlate with the study of 24 hours post reinjection of 201 TI to determine the presence of having knitted viable myocardium. Material and methods: 29 patients were studied with coronary arterial illness (EAC) to who are carried out SPECT 201 TI in rest with images of 15 minutes, 24 late hours and 24 hours reinjection, by means of the administration of 201 TI to dose of 130 MBq and reinjection with 37 MBq. and Gated-SPECT 99m Tc-SESTAMIBI in effort or stimulation of coronary reservation, later to the administration of 1110 MBq. Results: 29 patients were included according to inclusion approaches and exclusion, of those which 22 (75.86%) they correspond at the masculine sex and 7 (24.13%) to the feminine one, with an average of 62.1 year-old age, 2320 segments myocardial were analysed so much it is phase post-effort as rest; they were diagnosed a total of 264 segments with heart attack, of which viability myocardium was observed in 174 segments. The statistical tests are analysis of frequencies. The non parametric test of Wilcoxon and Mann-Whitney. Conclusions: the viability myocardial at the 24 late hours and 24 hours reinjection was similar; significant difference exists between the study of 15 minutes and 24 hours reinjection, ischemic illness was also demonstrated in territories different to the heart attack area in the studies of 15 minutes, late 24 hours and 24 hours reinjection. (Author)

  7. Self-gated fat-suppressed cardiac cine MRI.

    Science.gov (United States)

    Ingle, R Reeve; Santos, Juan M; Overall, William R; McConnell, Michael V; Hu, Bob S; Nishimura, Dwight G

    2015-05-01

    To develop a self-gated alternating repetition time balanced steady-state free precession (ATR-SSFP) pulse sequence for fat-suppressed cardiac cine imaging. Cardiac gating is computed retrospectively using acquired magnetic resonance self-gating data, enabling cine imaging without the need for electrocardiogram (ECG) gating. Modification of the slice-select rephasing gradients of an ATR-SSFP sequence enables the acquisition of a one-dimensional self-gating readout during the unused short repetition time (TR). Self-gating readouts are acquired during every TR of segmented, breath-held cardiac scans. A template-matching algorithm is designed to compute cardiac trigger points from the self-gating signals, and these trigger points are used for retrospective cine reconstruction. The proposed approach is compared with ECG-gated ATR-SSFP and balanced steady-state free precession in 10 volunteers and five patients. The difference of ECG and self-gating trigger times has a variability of 13 ± 11 ms (mean ± SD). Qualitative reviewer scoring and ranking indicate no statistically significant differences (P > 0.05) between self-gated and ECG-gated ATR-SSFP images. Quantitative blood-myocardial border sharpness is not significantly different among self-gated ATR-SSFP ( 0.61±0.15 mm -1), ECG-gated ATR-SSFP ( 0.61±0.15 mm -1), or conventional ECG-gated balanced steady-state free precession cine MRI ( 0.59±0.15 mm -1). The proposed self-gated ATR-SSFP sequence enables fat-suppressed cardiac cine imaging at 1.5 T without the need for ECG gating and without decreasing the imaging efficiency of ATR-SSFP. © 2014 Wiley Periodicals, Inc.

  8. Therapeutic effect of co-enzyme Q10 on idiopathic dilated cardiomyopathy: assessment by iodine-123 labelled 15-(p-iodophenyl)-3(R,S)-methylpentadecanoic acid myocardial single-photon emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong-ih [Department of Internal Medicine, Nishiyodo Hospital, Nishiyodo (Japan); Sawada, Yoshihiro [Department of Internal Medicine, Nishiyodo Hospital, Nishiyodo (Japan); Fujiwara, Go [Department of Radiology, Nishiyodo Hospital, Nishiyodo (Japan); Chiba, Hiroshi [Department of Internal Medicine, Mimihara General Hospital, Mimihara (Japan); Nishimura, Tsunehiko [Division of Tracer Kinetics, Biomedical Research Center, Osaka University Medical School, Osaka (Japan)

    1997-06-10

    It has been reported that myocardial mitochondrial function can be improved by the administration of co-enzyme Q10 (CoQ10). Recently, iodine-123 labelled 15-(p-iodophenyl)-3-(R,S)-methylpentadecanoic acid (BMIPP) was developed for metabolic imaging using single-photon emission tomography (SPET). This study was conducted to determine whether the therapeutic effects of CoQ10 on idiopathic dilated cardiomyopathy can be evaluated by BMIPP myocardial SPET. Fifteen patients, comprising 14 men and one woman (mean age: 64{+-}12 years), were examined. CoQ10 was administered at 30 mg/day for a period of 35.7{+-}12.4 days. BMIPP myocardial SPET was carried out before and after CoQ10 treatment. The count ratio of the heart (H) to the upper mediastinum (M) (H/M ratio) was calculated using a region of interest method with anterior planar imaging. Representative short-axis tomograms were divided into 27 segments (three slices x nine segments). Each segmental score was analysed semiquantitatively using a four-point scoring system (normal=0, mild low uptake=1, severe low uptake=2, defect=3). The H/M ratio showed a significant improvement, from 2.39{+-}0.39 to 2.54{+-}0.47, after treatment (P<0.05). The BMIPP total defect score after CoQ10 treatment was significantly decreased to 10.1{+-}4.3, compared to 13.9{+-}4.5 without CoQ10 treatment (P<0.001). However, the percent fractional shortening measured using echocardiography was not significantly different before and after CoQ treatment (19.2{+-}8.1 vs 19.7{+-}7.1). BMIPP myocardial SPET was confirmed to be sensitive in evaluating the therapeutic effects of CoQ10 in patients with idiopathic dilated cardiomyopathy. This method is unique, since the therapeutic effects can be estimated from the perspective of metabolic SPET imaging. (orig.). With 5 figs., 1 tab.

  9. : Myocardial Perfusion

    OpenAIRE

    Dacher, Jean-Nicolas; Lefebvre, V.; Dubourg, Bernard; Deux, Jean-François; Caudron, Jérôme

    2013-01-01

    International audience; The analysis of myocardial perfusion is a key step in the cardiac MRI examination. In routine work, this exploration carried out at rest is based on the qualitative first pass study of gadolinium with an ECG-triggered saturation recovery bFFE sequence. In view of recent knowledge, the analysis of the myocardial perfusion under vasodilator stress may be carried out by scintigraphy or MRI, the latter benefiting from the absence of exposure to ionizing rays and a lower co...

  10. Use of iodine-123 metaiodobenzylguanidine myocardial imaging to predict the effectiveness of {beta}-blocker therapy in patients with dilated cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Fukuoka, Shuji [Department of Radiology, National Cardiovascular Center, Osaka (Japan); Hayashida, Kohei [Department of Radiology, National Cardiovascular Center, Osaka (Japan); Hirose, Yoshiaki [Department of Radiology, National Cardiovascular Center, Osaka (Japan); Shimotsu, Yoriko [Department of Radiology, National Cardiovascular Center, Osaka (Japan); Ishida, Yoshio [Department of Radiology, National Cardiovascular Center, Osaka (Japan); Kakuchi, Hiroyuki [Department of Internal Medicine, National Cardiovascular Center, Osaka (Japan); Eto, Tanenao [First Department of Internal Medicine, Miyazaki Medical College, Miyazaki (Japan)

    1997-05-01

    We studied 13 patients with dilated cardiomyopathy (DCM) and seven normal subjects. We obtained myocardial SPET images 15 min and 4 h after administration of {sup 123}I-MIBG (111 MBq). Studies were performed in the patients with DCM before and 1 and 3 months after the administration of metoprolol and in the normal subjects. We calculated the regional {sup 123}I-MIBG washout rate (r-WR) in the SPET image, and the global {sup 123}I-MIBG washout rate (g-WR) and heart-mediastinum activity ratio (H/M) using the anterior planar image. We classified patients into those showing a {>=}5% increase in LV ejection fraction (LVEF) at 3 months compared with LVEF values before the treatment (group I, n=7) and those showing a <5% increase in LVEF (group II, n=6). In normal subjects, the r-WR values in each of the anterior, lateral, septal and inferior segments were significantly lower than those in groups I and II. These values were 18%{+-}9%, 18%{+-}15%, 20%{+-}12% and 21%{+-}15%, respectively. This study demonstrated that with regional assessment {sup 123}I-MIBG SPET imaging can be used to predict the functional improvement of LVEF at 1 month of {beta}-blocker therapy in patients with DCM. (orig./VHE). With 4 figs., 1 tab.

  11. Radioiodinated SB 207710 as a radioligand in vivo: imaging of brain 5-HT4 receptors with SPET

    International Nuclear Information System (INIS)

    Pike, Victor W.; Halldin, Christer; Nobuhara, Kenji; Swahn, Carl-Gunnar; Karlsson, Per; Olsson, Hans; Larsson, Stig; Schnell, Per-Olof; Farde, Lars; Hiltunen, Julka; Mulligan, Rachel S.; Hume, Susan P.; Hirani, Ella; Whalley, Jaqueline; Pilowsky, Lyn S.; Ell, Peter J.

    2003-01-01

    Single-photon emission tomography (SPET) and positron emission tomography (PET), when coupled to suitable radioligands, are uniquely powerful for investigating the status of neurotransmitter receptors in vivo. The serotonin subtype-4 (5-HT 4 ) receptor has discrete and very similar distributions in rodent and primate brain. This receptor population may play a role in normal cognition and memory and is perhaps perturbed in some neuropsychiatric disorders. SB 207710 [(1-butyl-4-piperidinylmethyl)-8-amino-7-iodo-1,4-benzodioxan-5-carboxylate is a selective high-affinity antagonist at 5-HT 4 receptors. We explored radioiodinated SB 207710 as a possible radioligand for imaging 5-HT 4 receptors in vivo. Rats were injected intravenously with iodine-125 labelled SB 207710, euthanised at known times and dissected to establish radioactivity content in brain tissues. Radioactivity entered brain but cleared rapidly and to a high extent from blood and plasma. Between 45 and 75 min after injection, the ratios of radioactivity concentration in each of 12 selected brain tissues to that in receptor-poor cerebellum correlated with previous measures of 5-HT 4 receptor density distribution in vitro. The highest ratio was about 3.4 in striatum. SB 207710 was labelled with iodine-123 by an iododestannylation procedure. A cynomolgus monkey was injected intravenously with [ 123 I]SB 207710 and examined by SPET. Maximal whole brain uptake of radioactivity was 2.3% of the injected dose at 18 min after radioligand injection. Brain images acquired between 9 and 90 min showed high radioactivity uptake in 5-HT 4 receptor-rich regions, such as striatum, and low uptake in receptor-poor cerebellum. At 169 min the ratio of radioactivity concentration in striatum to that in cerebellum was 4.0. In a second SPET experiment, the cynomolgus monkey was pretreated with a selective 5-HT 4 receptor antagonist, SB 204070, at 20 min before [ 123 I]SB 207710 injection. Radioactivity in all brain regions was

  12. [123I]FP-CIT (DaTSCAN) and SPET in the diagnostics of Parkinson's disease and Parkinsonian syndromes

    International Nuclear Information System (INIS)

    Chmielowski, K.; Szalus, B.; Pietrzykowski, J.; Brodacki, B.; Kotowicz, J.; Skrobowska, E.

    2003-01-01

    The aim of study was to verify the diagnostic value of the radiopharmaceutic [ 123I ]FP-CIT (DaTSCAN) in functional imaging of the presynaptical dopaminergic system in patients with Parkison's disease and parkinsonian syndromes: multiple system atrophy, orthostatic hypotonia Shy-Drager, essential tremor. That pilot study group consisted of 8 patients in which either preliminary diagnosis or suspicion of Parkinson's disease, parkinsonian syndrome or multiple system atrophy was set. Imaging of the brain with SPET (dual head detector Varicam Elscint) and MRI were performed. The radiopharmaceutic [ 123I ] FP-CIT (DaTSCAN) was administered intravenously in the dose 145 -148 MBq. SPET images were reconstructed by filtered backprojection with the use of Butterworth filter. The images were inspected visually. Images from SPET and MRI were superimposed by means of the workstation Hermes (Nucklear Diagnostic) with designatad regions interest (ROI) in the striatum and occipital cortex in order to assess semiquantitatively the binding of dopamine transporter. In the group of 8 patients evaluated with the use of [ 123I ]FP-CIT DaTSCAN four had normal results, and four - abnormal. The preliminary diagnosis was sustained in 3/8 of patients (including Parkinson's disease in two patients and multiple system atrophy in one patient). In the remainig 5 patients the preliminary diagnosis was changed, namely: in 2 cases the essential tremor was diagnosed, in 1 case - Parkinson's disease, in 1 case - orthostaic Sky-Drager, and in 1 case - despite the tremor of the upper limbs - results were normal. In all 8 patients the tracer proved to be useful in the confirmation of clinical diagnosis, especially in the differentiation between the essential tremor and Parkinson's disease. In the case of multiple system atrophy the imaging revealed significant loss of nigrostriatal dopaminergic neurons. Such loss was observed also in the cases of Parkinson's disease affecting the posterior parts of the

  13. Parieto-occipital hypoperfusion in late whiplash syndrome: first quantitative SPET study using technetium-99m bicisate (ECD)

    International Nuclear Information System (INIS)

    Otte, A.; Ettlin, T.; Fierz, L.; Mueller-Brand, J.

    1996-01-01

    Brain single-photon emission tomography (SPET) with N,N''-1,2-ethylene-diylbis-L-cysteine diethyl ester dihydrochloride (ECD) was performed on ten patients with a clinically high grade late whiplash syndrome and on 11 controls. Two independent readers blinded to the clinical diagnosis were able to separate the ten patients from normal controls. All these patients had qualitative bilateral parieto-occipital hypoperfusion. To confirm this, the perfusion rate of parieto-occipital over global (perfusion index) was calculated after drawing elliptical regions of interest in transversal-oblique slices. The perfusion indices in patients were significantly lower than in controls as tested by the Mann-Whitney U test. This quantitative study proves our recent qualitatively analysed observation. (orig./MG)

  14. Advances in the understanding of early Huntington's disease using the functional imaging techniques of PET and SPET

    International Nuclear Information System (INIS)

    Andrews, T.C.; Brooks, D.J.

    1998-01-01

    The functional imaging techniques of positron emission tomography (PET) and single photon emission tomography (SPET) have been used to study regional brain function in Huntington's disease (HD) in vivo. Reduced striatal glucose metabolism and dopamine receptor binding are evident in all symptomatic HD patients and in ∼50% of asymptomatic adult mutation carriers. These characteristics correlate with clinical measures of disease severity. Reduced cortical glucose metabolism and dopamine receptor binding, together with reduced striatal and cortical opioid receptor binding, have also been demonstrated in symptomatic patients with HD. Repeat PET measures of striatal function have been used to monitor the progression of this disease objectively. In the future, functional imaging will provide a valuable way of assessing the efficacy of both fetal striatal cell implants and putative neuroprotective agents, such as nerve growth factors. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  15. Kinetic modelling of [{sup 123}I]CNS 1261--a potential SPET tracer for the NMDA receptor

    Energy Technology Data Exchange (ETDEWEB)

    Erlandsson, Kjell E-mail: k.erlandsson@nucmed.ucl.ac.uk; Bressan, Rodrigo A.; Mulligan, Rachel S.; Gunn, Roger N; Cunningham, Vincent J.; Owens, Jonathan; Wyper, David; Ell, Peter J.; Pilowsky, Lyn S

    2003-05-01

    N-(1-napthyl)-N'-(3-[{sup 123}I]-iodophenyl)-N-methylguanidine ([{sup 123}I]CNS 1261) is a novel SPET ligand developed for imaging the NMDA receptor intra-channel MK 801/PCP/ketamine site. Data was acquired in 7 healthy volunteers after bolus injection of [{sup 123}I]CNS 1261. Kinetic modeling showed reversible tracer binding. Arterial and venous time-activity curves overlapped after 90 min. The rank order of binding was: Thalamus > striatum > cortical regions > white matter. This distribution concurs with [{sup 11}C]-ketamine and [{sup 18}F]-memantine PET studies . These data provide a methodological basis for further direct in vivo challenge studies.

  16. Ketamine displaces the novel NMDA receptor SPET probe [{sup 123}I]CNS-1261 in humans in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Stone, James M. [Institute of Psychiatry, King' s College London, De Crespigny Park London, SE5 8AF (United Kingdom)]. E-mail: j.stone@iop.kcl.ac.uk; Erlandsson, Kjell [Institute of Nuclear Medicine, University College London, London, W1N 8AA (United Kingdom); Arstad, Erik [Institute of Psychiatry, King' s College London, De Crespigny Park London, SE5 8AF (United Kingdom); Bressan, Rodrigo A. [Institute of Psychiatry, King' s College London, De Crespigny Park London, SE5 8AF (United Kingdom); Squassante, Lisa [GlaxoSmithKline (GSK), Verona 37135 (Italy); Teneggi, Vincenza [GlaxoSmithKline (GSK), Verona 37135 (Italy); Ell, Peter J. [Institute of Nuclear Medicine, University College London, London, W1N 8AA (United Kingdom); Pilowsky, Lyn S. [Institute of Psychiatry, King' s College London, De Crespigny Park London, SE5 8AF (United Kingdom); Institute of Nuclear Medicine, University College London, London, W1N 8AA (United Kingdom)

    2006-02-15

    [{sup 123}I]CNS-1261 [N-(1-naphthyl)-N'-(3-iodophenyl)-N-methylguanidine] is a high-affinity SPET ligand with selectivity for the intrachannel PCP/ketamine/MK-801 site of the N-methyl-D-aspartate (NMDA) receptor. This study evaluated the effects of ketamine (a specific competitor for the intrachannel PCP/ketamine/MK-801 site) on [{sup 123}I]CNS-1261 binding to NMDA receptors in vivo. Ten healthy volunteers underwent 2 bolus-plus-infusion [{sup 123}I]CNS-1261 scans, one during placebo and the other during a ketamine challenge. Ketamine administration led to a significant decrease in [{sup 123}I]CNS-1261 V {sub T} in most of the brain regions examined (P<.05). [{sup 123}I]CNS-1261 appears to be a specific ligand in vivo for the intrachannel PCP/ketamine/MK-801 NMDA binding site.

  17. Practical benefit of [123I[FP-CIT SPET in the demonstration of the dopaminergic deficit in Parkinson's disease

    International Nuclear Information System (INIS)

    Booij, J.; Tissingh, G.; Winogrodzka, A.; Boer, G.J.; Wolters, E.C.; Royen, E.A. van

    1997-01-01

    Loss of striatal dopamine (DA) transporters in Parkinson's disease (PD) has been accurately assessed in vivo by single-photon emission tomography (SPET) studies using [ 123 I[β-CIT. However, these studies have also shown that adequate imaging of the striatal DA transporter content can be performed only 20-30 h following the injection of [ 123 I[β-CIT, which is not convenient for routine out-patient evaluations. Recently, a new ligand, N-ω-fluoropropyl-2β-carbomethoxy-3β-(4-iodophenyl)tropane (FP-CIT), became available for in vivo imaging of the DA transporter. The faster kinetics of [ 123 I[FP-CIT have been shown to allow adequate acquisition as early as 3 h following injection. In the present study, loss of striatal DA transporters in five non-medicated PD patients was assessed on two consecutive SPET scans, one with [ 123 I[β-CIT (24 h following injection) and one with [ 123 I[FP-CIT (3 h following injection). The ratios of specific to non-specific [ 123 I[FP-CIT uptake in the caudate nucleus and putamen were consistently 2.5-fold lower than those of [ 123 I[β-CIT. However, when the uptake ratio of both ligands in these brain regions of patients was expressed as a percentage of the uptake ratio found in healthy controls, both the decrease and the variation of the data were similar. It is concluded on the basis of these findings that [ 123 I[FP-CIT seems as good as [ 123 I[β-CIT for the assessment of the dopaminergic deficit in PD. The faster kinetics of [ 123 I[FP-CIT are a clear advantage. (orig.). With 3 figs

  18. Memory functions and rCBF 99mTc-HMPAO SPET: developing diagnostics in Alzheimer's disease

    International Nuclear Information System (INIS)

    Elgh, Eva; Naesman, Birgitta; Sundstroem, Torbjoern; Aahlstroem, Katrine Riklund; Nyberg, Lars

    2002-01-01

    Alzheimer's disease (AD) is a primary degenerative disease of the brain. The prevalence increases with age, with devastating consequences for the individual and society. The aim of this study was to evaluate whether patients with early AD show an altered regional cerebral blood flow (rCBF) compared with control persons. Furthermore, we aimed to investigate the correlation between rCBF in sublobar volumes of the brain and performance on memory tests. Memory tests were chosen to evaluate episodic and semantic memory. Fourteen patients (aged 75.2±8.8 years) with early AD and 15 control persons (aged 71.4±3.2 years) were included. rCBF measurements with single-photon emission tomography (SPET) using technetium-99m hexamethylpropylene amine oxime (HMPAO) were performed. The rCBF 99m Tc-HMPAO SPET images were spatially transformed to fit a brain atlas and normalised for differences in rCBF (Computerised Brain Atlas software). Cortical and subcortical volumes of interest (VOIs) were analysed and compared. Compared with the controls, AD patients showed a significantly lower rCBF ratio in temporoparietal regions, including the left hippocampus. The diagnostic sensitivity and specificity for AD were high in temporoparietal regions. AD patients had significantly reduced performance on semantic and, in particular, episodic memory tests compared with age-matched normative data, and their performance on several episodic tests correlated with rCBF ratios in parietal and temporal regions, including the left hippocampus. The correlation between rCBF ratio and level of episodic memory performance suggests that abnormalities in rCBF pattern underlie impaired episodic memory functioning in AD. (orig.)

  19. Multivariate cluster analysis of dynamic iodine-123 iodobenzamide SPET dopamine D{sub 2}receptor images in schizophrenia

    Energy Technology Data Exchange (ETDEWEB)

    Acton, P.D. [Inst. of Nuclear Medicine, Univ. Coll. London Medical School, London (United Kingdom); Pilowsky, L.S. [Institute of Psychiatry, London (United Kingdom); Costa, D.C. [Inst. of Nuclear Medicine, Univ. Coll. London Medical School, London (United Kingdom); Ell, P.J. [Inst. of Nuclear Medicine, Univ. Coll. London Medical School, London (United Kingdom)

    1997-02-01

    This paper describes the application of a multivariate statistical technique to investigate striatal dopamine D{sub 2}receptor concentrations measured by iodine-123 iodobenzamide ({sup 123}I-IBZM) single-photon emission tomography (SPET). This technique enables the automatic segmentation of dynamic nuclear medicine images based on the underlying time-activity curves present in the data. Once the time-activity curves have been extracted, each pixel can be mapped back on to the underlying distribution, considerably reducing image noise. Cluster analysis has been verified using computer simulations and phantom studies. The technique has been applied to SPET images of dopamine D {sub 2}receptors in a total of 20 healthy and 20 schizophrenic volunteers (22 male, 18 female), using the ligand {sup 123}I-IBZM. Following automatic image segmentation, the concentration of striatal dopamine D {sub 2}receptors shows a significant left-sided asymmetry in male schizophrenics compared with male controls. The mean left-minus-right laterality index for controls is -1.52 (95% CI -3.72-0.66) and for patients 4.04 (95% CI 1.07-7.01). Analysis of variance shows a case-by-sex-by-side interaction, with F=10.01, P=0.005. We can now demonstrate that the previously observed male sex-specific D {sub 2}receptor asymmetry in schizophrenia, which had failed to attain statistical significance, is valid. Cluster analysis of dynamic nuclear medicine studies provides a powerful tool for automatic segmentation and noise reduction of the images, removing much of the subjectivity inherent in region-of-interest analysis. The observed striatal D {sub 2}asymmetry could reflect long hypothesized disruptions in dopamine-rich cortico-striatal-limbic circuits in schizophrenic males. (orig.). With 4 figs., 2 tabs.

  20. Myocardial scintigraphy

    International Nuclear Information System (INIS)

    Bunko, Hisashi; Hisada, Kinichi

    1982-01-01

    Among the various methods of image diagnosis of the cardiovascular disorder, nuclear cardiology provides noninvasive means for evaluation of myocardial perfusion as well as morphological and functional informations. In this article, clinical application and image diagnosis of myocardial scintigraphy including Tl-201 myocardial perfusion scintigraphy, single photon emission computed tomography with Tl-201, acute myocardial infarction scintigraphy with Tc-99m-pyrophosphate and Ga-67 imaging of the heart, were discussed. Multiplanar imaging of the heart with Tl-201 after stress and at redistribution was the accepted method for detection and evaluation of the ischemic heart disease. Although it achieved high sensitivity and specificity for ischemic heart disease, detection of the small ischemia and quantation of the regional Tl-201 accumulation were difficult with conventional multiplanar imaging. Application of emission computed tomography improved detectability and quantitativity of the ischemia. However, 7-pinhole tomography did not increase the diagnostic accuracy significantly. It had limited clinical applicability due to poor quantitativity in spite of improved image contrast and its tomographic nature. Advantage and limitation of these tomographic imaging and multiplanar imaging were discussed. Problems and prognostic significance of pyrophosphate imaging of the acute myocardial infarction were also discussed. Visualization of the heart with Ga-67 was helpful for identification of the tumor or inflammation of the heart as well as evaluation of the effect of the therapy. (author)

  1. The clinical benefit of imaging striatal dopamine transporters with [123I]FP-CIT SPET in differentiating patients with presynaptic parkinsonism from those with other forms of parkinsonism

    International Nuclear Information System (INIS)

    Booij, J.; Speelman, J.DE.; Horstink, M. W.I.M.; Wolters, E.C.

    2001-01-01

    [ 123 I]FP-CIT (N-ω-fluoropropyl-2β-carbomethoxy-3β-(4-iodophenyl)nortropane) has been developed successfully as a radioligand for single-photon emission tomography (SPET) imaging of dopamine transporters, which are situated in the membrane of dopaminergic neurons. Imaging of these transporters has shown promise as a clinical tool to detect degeneration of the dopaminergic nigrostriatal pathway. Several ''presynaptic parkinsonian'' syndromes, such as Parkinson's disease or multiple system atrophy, are characterised by degeneration of the nigrostriatal pathway. [ 123 I]FP-CIT SPET imaging studies have shown the ability to detect loss of striatal dopamine transporters in such syndromes. However, in clinical practice it is sometimes difficult, but important, to discriminate patients with ''presynaptic parkinsonism'' from those with other forms of parkinsonism not characterised by loss of presynaptic dopaminergic cells (e.g. psychogenic parkinsonism or drug-induced postsynaptic parkinsonism). In these inconclusive cases, it may be of value to confirm or exclude the existence of degeneration of nigrostriatal dopaminergic cells by using imaging techniques such as [ 123 I]FP-CIT SPET. Using [ 123 I]FP-CIT SPET, we have imaged the striatal dopamine transporters in a group of patients with inconclusive forms of parkinsonism, and, moreover, have been able to perform clinical follow-up of these patients 2-4 years after imaging. In 33 inconclusive cases, ratios of specific to non-specific binding were calculated for the caudate nucleus and putamen following [ 123 I]FP-CIT SPET imaging and compared with ratios obtained in healthy controls. In nine of the patients, degeneration of the nigrostriatal pathway was found scintigraphically and in all these cases, presynaptic parkinsonism was confirmed by clinical follow-up. In the other 24 subjects no degeneration was found scintigraphically. Forms of parkinsonism other than the presynaptic were confirmed at follow-up in 19 cases

  2. Perioperative myocardial perfusion scintigraphy at rest with technetium 99m methoxyisobutylisonitrile before and after coronary bypass operations

    International Nuclear Information System (INIS)

    Raff, W.; Sialer, G.; Pfeiffer, A.; Schulthess, G.K. von; Segesser, L. von; Turina, M.

    1991-01-01

    Eighteen patients were examined at rest by technetium 99m methoxyisobutylisonitrile ( 99m Tc-MIBI) myocardial scintigraphy 1 day before and 1 week after aorto-coronary bypass operation with planar and single photon emission tomography (SPET) imaging. One day postoperatively, a planar scintigraph in the intensive care unit (ICU) was done. Inter-observer variability was 3.8% for all examinations and for SPET alone, 3.9%. The quality of the planar images taken under emergency conditions in the ICU was quite comparable with those taken under routine conditions. The postoperative myocardial infarction in a patient who died 6 days later could clearly be demonstrated. In 16.2% of all segments which were hypoperfused at rest on properative scintigraphy, an amelioration of perfusion could be shown in the 1st week after the bypass operation. 99m Tc-MIBI proved to be a useful agent to assess perioperative perfusion, in the ICU as well as under standard conditions. (orig.)

  3. Myocardial scintigraphy in acute myocardial infarction

    International Nuclear Information System (INIS)

    Faerestrand, S.

    1984-01-01

    The sensitivity and specificity of 99m Tc-PYP myocardial scintigraphy for detecting an acute myocardial infarction were studied in 39 patients hospitalized because of central chest pain. One myocardial scintigraphic examination was done in each patient between the first and sixth day after the chest pain had started. Twenty-two patients had a myocardial infarction based on history, ECG and enzym values and myocardial scintigraphy was positive in twenty of these. Three patients with left bundle branch block and myocardial infarction all had a positive myocardial scintigram and the one patient with negative ECG and myocardial infarction also had a positive myocardial scintigram. The sensitivity is 91% and the specificity is 91.7% for 99m Tc-PYP myocardial scintigraphy in the detection of acute myocardial infarction. No complications were seen. (Auth.)

  4. Rapid gated Thallium-201 perfusion SPECT - clinically feasible?

    International Nuclear Information System (INIS)

    Wadhwa, S.S.; Mansberg, R.; Fernandes, V.B.; Wilkinson, D.; Abatti, D.

    1998-01-01

    Full text: Standard dose energy window optimised Thallium-201 (Tl-201) SPECT has about half the counts of a standard dose from Technetium-99m Sestamibi (Tc99m-Mibi) gated perfusion SPECT. This study investigates the clinical feasibility of rapid energy window optimised Tl-201 gated perfusion SPECT (gated-TI) and compares quantitative left ventricular ejection fraction (LVEF) and visually assessed image quality for wall motion and thickening to analogous values obtained from Tc99m-Mibi gated perfusion SPECT (gated - mibi). Methods: We studied 60 patients with a rest gated Tl-201 SPECT (100 MBq, 77KeV peak, 34% window, 20 sec/projection) followed by a post stress gated Sestamibi SPECT (1GBq, 140KeV, 20% window, 20 sec/projection) separate dual isotope protocol. LVEF quantitation was performed using commercially available software (SPECTEF, General Electric). Visual grading of image quality for wall thickening and motion was performed using a three-point scale (excellent, good and poor). Results: LVEF for gated Tl-201 SPECT was 59.6 ± 12.0% (Mean ± SD). LVEF for gated Sestamibi SPECT was 60.4 ±11.4% (Mean ± SD). These were not significantly different (P=0.27, T-Test). There was good correlation (r=0.9) between gated-TI and gated-mibi LVEF values. The quality of gated-Tl images was ranked as excellent, good and poor in 12, 50 and 38% of the patients respectively. Image quality was better in gated-mibi SPECT, with ratings of 12, 62 and 26% respectively. Conclusion: Rapid gated Thallium-201 acquisition with energy window optimisation can be effectively performed on majority of patients and offers the opportunity to assess not only myocardial perfusion and function, as with Technetium based agents, but also viability using a single day one isotope protocol

  5. Graves' disease in an adolescent with dual congenital ectopia and no orthotopic thyroid gland identified by Tc-99m-pertechnetate SPET/CT imaging.

    Science.gov (United States)

    Qiu, Zhong-Ling; Xue, Yan-Li; Shen, Chen-Tian; Zhu, Rui-Sen; Luo, Quan-Yong

    2013-01-01

    This is the first case of Graves' disease in an adolescent with lingual and prelaryngeal dual congenital ectopia and no orthotopic thyroid gland identified by technetium-99m-pertechnetate (99mTcO-4) SPET/CT imaging in a 15 years old boy. After 8 weeks treatment with methimazole, Graves' disease subsided. Fine needle aspiration cytology of the mass revealed the normal colloid and normal follicular cells without an atypia or lymphoid elements, suggesting a benign ectopic thyroid gland. In conclusion, there is no report in the literature with DETT lingual and prelaryngeal absence of orthotopic thyroid tissue and Graves' disease as in our case. This case also highlights the potential ascendancy of 99mTcO-4 SPET/CT in diagnosing the DETT.

  6. Clinical evaluation of no-carrier-added meta-[123I]iodobenzylguanidine for myocardial scintigraphy

    International Nuclear Information System (INIS)

    Knickmeier, M.; Matheja, P.; Schaefers, K.P.; Schober, O.; Schaefers, M.; Kies, P.; Breithardt, G.

    2000-01-01

    The aim of the present study was to evaluate the clinical value of myocardial scintigraphy with n.c.a. [ 123 I]MIBG in patients with tachyarrhythmias. The study population comprised 24 patients with tachyarrhythmogenic diseases routinely studied by cardiac single-photon emission tomography (SPET) with [ 123 I]MIBG. Twelve of the 24 patients were studied with c.a. [ 123 I]MIBG (seven females and five males; mean age 42±13 years, range 20-60 years), whereas the other 12 were studied with n.c.a. [ 123 I]MIBG (ten females, two males; mean age 41±11 years, range 18-60 years, P=NS). For quantification of the specific uptake in the different organs, count ratios were calculated on SPET images acquired 4 h p.i. Visual analysis of all [ 123 I]MIBG scans showed improved image quality (improved contrast between heart and neighbouring organs) in n.c.a. studies as compared with c.a. studies. A significantly higher heart/left atrial blood ratio was found in the n.c.a. studies as compared with the c.a. studies (10.3±3.2 vs 5.3±1.3, P=0.0003); furthermore, significantly higher heart/lung and heart/liver ratios (2.5±0.6 vs 1.5±0.3, P=0.0002, and 0.8±0.2 vs 0.6±0.1, P=0.0006, respectively) were obtained in the c.a. studies, whereas lung/left atrial blood and liver/left atrial blood ratios showed no significant differences (4.2±1.3 vs 3.6±1.1, P=0.39, and 13.7±5.2 vs 9.6±2.2, P=0.21, respectively). In conclusion, the use of n.c.a. [ 123 I]MIBG yields a significantly higher myocardial uptake associated with improvement in contrast between the heart and neighbouring organs and is therefore superior to the commercially available c.a. [ 123 I]MIBG for use in clinical and research studies of the myocardial presynaptic sympathetic nervous system. Furthermore, our data indicate that for quantification the use of a left atrial blood reference region of interest, which is only available on SPET studies, is to be recommended.(orig./MG) (orig.)

  7. Whole-body biodistribution, radiation absorbed dose, and brain SPET imaging with [{sup 123}I]5-I-A-85380 in healthy human subjects

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, Masahiro; Tamagnan, G.; Baldwin, R.M.; Khan, S.; Bozkurt, A. [Yale Univ., New Haven, CT (United States). School of Medicine; Seibyl, J.P.; Early, M. [Institute for Neurodegenerative Disorders, New Haven, CT (United States); Vaupel, B.D.; Horti, A.G.; Mukhin, A.G.; Kimes, A.S. [Brain Imaging Center, Intramural Research Program, National Institute on Drug Abuse, Baltimore, MD (United States); Zoghbi, S.S. [Yale Univ., New Haven, CT (United States). Dept. of Radiology; Koren, A.O.; London, E.D. [Brain Imaging Center, Intramural Research Program, National Institute on Drug Abuse, Baltimore, MD (United States); Departments of Psychiatry and Biobehavioral Sciences, UCLA, Los Angeles, CA (United States); Innis, R.B. [Molecular Imaging Branch, National Institutes of Mental Health (United States)

    2002-02-01

    The biodistribution of radioactivity after the administration of a new tracer for {alpha}4{beta}2 nicotinic acetylcholine receptors (nAChRs), [{sup 123}I]5-iodo-3-[2(S)-2-azetidinylmethoxy]pyridine (5-I-A-85380), was studied in ten healthy human subjects. Following administration of 98{+-}6 MBq [{sup 123}I]5-I-A-85380, serial whole-body images were acquired over 24 h and corrected for attenuation. One to four brain single-photon emission tomography (SPET) images were also acquired between 2.5 and 24 h. Estimates of radiation absorbed dose were calculated using MIRDOSE 3.1 with a dynamic bladder model and a dynamic gastrointestinal tract model. The estimates of the highest absorbed dose ({mu}Gy/MBq) were for the urinary bladder wall (71 and 140), lower large intestine wall (70 and 72), and upper large intestine wall (63 and 64), with 2.4-h and 4.8-h urine voiding intervals, respectively. The whole brain activity at the time of the initial whole-body imaging at 14 min was 5.0% of the injected dose. Consistent with the known distribution of {alpha}4{beta}2 nAChRs, SPET images showed the highest activity in the thalamus. These results suggest that [{sup 123}I]5-I-A-85380 is a promising SPET agent to image {alpha}4{beta}2 nAChRs in humans, with acceptable dosimetry and high brain uptake. (orig.)

  8. Single photon emission tomography (SPET) imaging of dopamine D2 receptors in the course of dopamine replacement therapy in patients with nocturnal myoclonus syndrome (NMS)

    International Nuclear Information System (INIS)

    Staedt, J.; Stoppe, G.; Riemann, H.; Hajak, G.; Ruether, E.; Koegler, A.; Emrich, D.

    1995-01-01

    Single photon emission tomography (SPET) permits the in vivo measurements of regional cerebral radioactivity in the human brain following the administration of compounds labeled with photon-emitting isotopes. According to our SPET findings of a reduced binding of [ 123 I]labeled (S)-2-hydroxy-3-iodo-6-methoxy-([1-ethyl-2-pyrrolidinyl]methyl) benzamide (IBZM) (a highly selective CNS D 2 dopamine receptor ligand) to D 2 dopamine receptors in striatal structures in untreated patients with nocturnal myoclonus syndrome (NMS) it seemed to be of interest to investigate whether there are changes in D 2 receptor binding under dopamine replacement therapy or not. We studied the uptake and distribution of [ 123 I]IBZM before and in the course of dopamine replacement therapy in four patients with severe insomnia caused by nocturnal myoclonus syndrome (NMS). We found an increase of the IBZM binding to D 2 receptors in the course of treatment, which was associated with an improvement of sleep quality. Reasons for this are discussed. The [ 123 I]IBZM SPET technique in conclusion offers an interesting tool for in vivo investigations of functional changes in the dopaminergic neurotransmitter system in longitudinal studies. (author)

  9. Dopamine transporter density in the basal ganglia assessed with [123I]IPT SPET in children with attention deficit hyperactivity disorder

    International Nuclear Information System (INIS)

    Cheon, Keun-Ah; Kim, Young-Kee; Namkoong, Kee; Kim, Chan-Hyung; Ryu, Young Hoon; Lee, Jong Doo

    2003-01-01

    Attention deficit hyperactivity disorder (ADHD) is a psychiatric disorder in childhood that is known to be associated with dopamine dysregulation. In this study, we investigated dopamine transporter (DAT) density in children with ADHD using iodine-123 labelled N-(3-iodopropen-2-yl)-2β-carbomethoxy-3β-(4-chlorophenyl) tropane ([ 123 I]IPT) single-photon emission tomography (SPET) and postulated that an alteration in DAT density in the basal ganglia is responsible for dopaminergic dysfunction in children with ADHD. Nine drug-naive children with ADHD and six normal children were included in the study. We performed brain SPET 2 h after the intravenous administration of [ 123 I]IPT and carried out both quantitative and qualitative analyses using the obtained SPET data, which were reconstructed for the assessment of the specific/non-specific DAT binding ratio in the basal ganglia. We then investigated the correlation between the severity scores of ADHD symptoms in children with ADHD assessed with ADHD rating scale-IV and the specific/non-specific DAT binding ratio in the basal ganglia. Drug-naive children with ADHD showed a significantly increased specific/non-specific DAT binding ratio in the basal ganglia compared with normal children. However, no significant correlation was found between the severity scores of ADHD symptoms in children with ADHD and the specific/non-specific DAT binding ratio in the basal ganglia. Our findings support the complex dysregulation of the dopaminergic neurotransmitter system in children with ADHD. (orig.)

  10. Dopamine transporter density in the basal ganglia assessed with [{sup 123}I]IPT SPET in children with attention deficit hyperactivity disorder

    Energy Technology Data Exchange (ETDEWEB)

    Cheon, Keun-Ah; Kim, Young-Kee; Namkoong, Kee; Kim, Chan-Hyung [Department of Psychiatry, College of Medicine, Yonsei University, Seoul (Korea); Ryu, Young Hoon; Lee, Jong Doo [Division of Nuclear Medicine, Department of Radiology, College of Medicine, Yonsei University, 146-92 Dogokdong, Gangnam-Gu, Seoul, 135-720 (Korea)

    2003-02-01

    Attention deficit hyperactivity disorder (ADHD) is a psychiatric disorder in childhood that is known to be associated with dopamine dysregulation. In this study, we investigated dopamine transporter (DAT) density in children with ADHD using iodine-123 labelled N-(3-iodopropen-2-yl)-2β-carbomethoxy-3β-(4-chlorophenyl) tropane ([{sup 123}I]IPT) single-photon emission tomography (SPET) and postulated that an alteration in DAT density in the basal ganglia is responsible for dopaminergic dysfunction in children with ADHD. Nine drug-naive children with ADHD and six normal children were included in the study. We performed brain SPET 2 h after the intravenous administration of [{sup 123}I]IPT and carried out both quantitative and qualitative analyses using the obtained SPET data, which were reconstructed for the assessment of the specific/non-specific DAT binding ratio in the basal ganglia. We then investigated the correlation between the severity scores of ADHD symptoms in children with ADHD assessed with ADHD rating scale-IV and the specific/non-specific DAT binding ratio in the basal ganglia. Drug-naive children with ADHD showed a significantly increased specific/non-specific DAT binding ratio in the basal ganglia compared with normal children. However, no significant correlation was found between the severity scores of ADHD symptoms in children with ADHD and the specific/non-specific DAT binding ratio in the basal ganglia. Our findings support the complex dysregulation of the dopaminergic neurotransmitter system in children with ADHD. (orig.)

  11. New gate opening hours

    CERN Multimedia

    GS Department

    2009-01-01

    Please note the new opening hours of the gates as well as the intersites tunnel from the 19 May 2009: GATE A 7h - 19h GATE B 24h/24 GATE C 7h - 9h\t17h - 19h GATE D 8h - 12h\t13h - 16h GATE E 7h - 9h\t17h - 19h Prévessin 24h/24 The intersites tunnel will be opened from 7h30 to 18h non stop. GS-SEM Group Infrastructure and General Services Department

  12. The role of FDG-PET, HMPAO-SPET and MRI in the detection of brain involvement in patients with systemic lupus erythematosus

    Energy Technology Data Exchange (ETDEWEB)

    Kao Chiahung [Department of Nuclear Medicine, Taichung Veterans General Hospital, Taichung (Taiwan, Province of China); Lan Jungliang [Division of Rheumatology, Taichung Veterans General Hospital, Taichung (Taiwan, Province of China); ChangLai Shengping [Department of Nuclear Medicine, Chung-Shan Medical and Dental College, Taichung (Taiwan, Province of China); Liao Kokaung [Electron Microscopic Laboratory, Chung-Shan Medical and Dental College, Taichung (Taiwan, Province of China); Yen Rouhfang; Chieng Poonung [Department of Nuclear Medicine, National Taiwan University Hospital, Taipei (Taiwan, Province of China)

    1999-02-01

    Involvement of the brain is one of the most important complications of systemic lupus erythematosus (SLE); however, its diagnosis is difficult due to the lack of effective imaging methods. We combined three brain imaging modalities - positron emission tomography with fluorine-18 2-fluoro-2-deoxy-d-glucose (FDG-PET), single-photon emission computed tomography with technetium-99m hexamethylpropylene amine oxime (HMPAO-SPET) and magnetic resonance imaging (MRI) - in order to detect brain involvement in SLE. Thirty-seven SLE patients, aged 22-45 years, were divided into three groups. Group 1 (G1) consisted of ten patients with major neuropsychiatric manifestations; group 2 (G2) consisted of 15 patients with minor manifestations; and group 3 (G3) consisted of 12 patients without manifestations. FDG-PET findings were abnormal in 51% of patients: 90% of G1, 67% of G2 and 0% of G3 patients respectively. HMPAO-SPET findings were abnormal in 62% of patients: 100% of G1, 73% of G2 and 17% of G3 patients respectively. MRI findings were abnormal in 35% of patients: 70% of G1, 40% of G2 and 0% of G3 patients respectively. Grey matter was more commonly involved than white matter; 62% of patients presented with lesions in the cerebral cortex, 27% with lesions in the basal ganglion, 5% with lesions in the cerebellum, and 19% with lesions in white matter. No white matter lesions were found on FDG-PET or HMPAO-SPET. However, in 19% of patients, MRI demonstrated abnormally high signal lesions in white matter. Forty-three percent of cases had positive serum anticardiolipin antibodies (ACA). However, ACA was not related to FDG-PET, HMPAO-SPET or MRI findings. It may be concluding that HMPAO-SPET is a more sensitive tool for detecting brain involvement in SLE patients when compared with FDG-PET or MRI. However, MRI is necessary for detecting lesions in white matter. (orig.) With 3 figs., 2 tabs., 46 refs.

  13. Iodine-123 N-methyl-4-iododexetimide: a new radioligand for single-photon emission tomographic imaging of myocardial muscarinic receptors

    International Nuclear Information System (INIS)

    Hicks, R.J.; Kassiou, M.; Eu, P.; Katsifis, A.G.; Garra, M.; Power, J.; Najdovski, L.; Lambrecht, R.M.

    1995-01-01

    Cardiac muscarinic receptor ligands suitable for positron emission tomography have previously been characterised. Attempts to develop radioligands of these receptors suitable for single-photon emission tomographic (SPET) imaging have not been successful due to high lung retention and high non-specific binding of previously investigated potential tracers. The purpose of this study was to evaluate the biodistribution and in vivo imaging characteristics of a new radiopharmaceutical, [ 123 I]N-methyl-4-iododexetimide. Biodistribution studies performed in rats showed high cardiac uptake (2.4% ID/g) 10 min after injection with a heart to lung activity ratio of 5:1. Specificity and stereoselectivity of cardiac binding were demonstrated using blocking experiments in rats. Dynamic imaging studies in anaesthetised greyhounds demonstrated rapid and high myocardial uptake and low lung binding with stable heart to lung activity ratios of >2.5:1 between 10 and 30 min, making SPET imaging feasible. Administration of an excess of an unlabelled muscarinic antagonist, methyl-quinuclidinyl benzylate rapidly displaced myocardial activity to background levels and the pharmacologically inactive enantiomer, [ 123 I]N-methyl-4-iodolevetimide, had no detectable cardiac uptake, indicating specific and stereoselective muscarinic receptor binding. SPET revealed higher activity in the inferior than in the anterior wall, this being consistent with previously described regional variation of cardiac parasympathetic innervation. [ 123 I]N-methyl-4-iododexetimide shows promise as an imaging agent for muscarinic receptor distribution in the heart and may be helpful in evaluating diverse cardiac diseases associated with altered muscarinic receptor function, including heart failure and diabetic heart disease. (orig.)

  14. Role of myocardial perfusion single photon emission computed tomography in pediatric cardiology practice

    Directory of Open Access Journals (Sweden)

    Sundaram P

    2009-01-01

    Full Text Available Diagnostic and prognostic power of myocardial perfusion imaging in patients with coronary artery disease has been demonstrated with planar imaging which was further improvised with addition of gated SPECT and newer Technetium labeled myocardial perfusion tracers like SestaMIBI, Tetrofosmin. Myocardial perfusion abnormalities at rest and after stress are considered to be the best predictors of cardiac event-free survival in adults with ischemic heart disease. This article highlights various myocardial perfusion imaging (MPIradiopharmaceuticals, exercise procedures, pharmacological stress protocols, indications for MPI and myocardial perfusion patterns in children with some of the common congenital and acquired heart diseases.

  15. Function's evaluation, perfusion and metabolism by positron emission tomography associated with multislice tomography (PET/CT) in patient with previous diagnosis to myocardial necrosis

    International Nuclear Information System (INIS)

    Campisi, Roxana; Aramayo, Natalia; Osorio, Amilcar

    2010-01-01

    A 64-years-old male patient with previous diagnosis of myocardial necrosis as assessed by myocardial perfusion gated single photon emission computed tomography (gSPECT) with 3-vessel-disease, left ventricular dysfunction and symptomatic by epigastric pain. The patient was referred for myocardial viability assessment by positron emission tomography (PET) to define clinical management decision. (authors) [es

  16. Impact of diabetes mellitus on worsening of the left ventricular ejection fraction in exercise-gated 201Tl myocardial single photon emission computed tomography in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Yamagishi, Hiroyuki; Yoshiyama, Minoru; Shirai, Naoya; Akioka, Kaname; Takeuchi, Kazuhide; Yoshikawa, Junichi

    2003-01-01

    It remains uncertain whether factors other than the severity of coronary artery disease (CAD) are associated with the worsening of the left ventricular ejection fraction (LVEF) by exercise. In the present study the impact of coronary risk factors on the worsening of LVEF by exercise was investigated in 391 patients with known or suspected CAD using exercise-gated 201 Tl scanning to calculate the LVEF. Significant worsening of the LVEF by exercise was defined as >4.7% (mean plus 1 SD of the value in 116 patients without CAD). Multivariate analysis revealed that diabetes mellitus (DM) was an independent risk factor for the worsening of LVEF by exercise in patients with multivessel (2- or 3-vessel) CAD with an odds ratio (95% confidence interval) of 2.2 (1.1-4.5, p=0.037). In 157 patients with 2- or 3-vessel CAD, 20 (23.5%) of 85 nondiabetic patients and 31 (43.1%, p=0.009 vs nondiabetic patients) of 72 diabetic patients showed significant worsening of LVEF by exercise. In patients with 2- or 3-vessel CAD, there was no significant difference in Gensini score or reversibility of perfusion defects between nondiabetic and diabetic patients. Thus, DM is a risk factor for worsening LVEF by exercise in addition to the severity of CAD. (author)

  17. Left ventricular function in response to dipyridamole stress: head-to-head comparison between {sup 82}Rubidium PET and {sup 99m}Tc-sestamibi SPECT ECG-gated myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Giorgi, Maria Clementina; Meneghetti, Jose Claudio; Soares, Jose; Izaki, Marisa; Falcao, Andrea; Imada, Rodrigo; Chalela, William; Oliveira, Marco Antonio de; Nomura, Cesar [Department of Radiology and Nuclear Medicine and Molecular Imaging Service - Heart Institute of the University of Sao Paulo Medical School, Sao Paulo (Brazil); Verberne, Hein J. [University of Amsterdam, Department of Nuclear Medicine, Academic Medical Center, P.O. Box 22700, Amsterdam (Netherlands)

    2017-05-15

    Myocardial perfusion imaging (MPI) with {sup 99m}Tc-sestamibi (sestamibi) SPECT and rubidium-82 ({sup 82}Rb) PET both allow for combined assessment of perfusion and left ventricular (LV) function. We sought to compare parameters of LV function obtained with both methods using a single dipyridamole stress dose. A group of 221 consecutive patients (65.2 ± 10.4 years, 52.9% male) underwent consecutive sestamibi and {sup 82}Rb MPI after a single dipyridamole stress dose. Sestamibi and {sup 82}Rb summed rest (SRS), stress (SSS) and difference (SDS) scores, and LV end-diastolic (EDV) and end-systolic (ESV) volumes and left ventricular ejection fraction (LVEF) were compared. Bland-Altman analysis showed that with increasing ESV and EDV the difference between the two perfusion tracers increased both at rest and post-stress. The mean difference in EDV and ESV between the two perfusion tracers at rest could both be independently explained by the {sup 82}Rb SDS and the sestamibi SRS. The combined models explained approximately 30% of the variation in these volumes between the two perfusion tracers (R{sup 2} = 0.261, p = 0.005; R{sup 2} = 0.296, p < 0.001, for EDV and ESV respectively). However, the mean difference in LVEF between sestamibi and {sup 82}Rb showed no significant trend post-stress (R{sup 2} = 0.001, p = 0.70) and only a modest linear increase with increasing LVEF values at rest (R{sup 2} = 0.032, p = 0.009). Differences in left ventricular volumes between sestamibi and {sup 82}Rb MPI increase with increasing volumes. However, these differences did only marginally affect LVEF between sestamibi and {sup 82}Rb. In clinical practice these results should be taken into account when comparing functional derived parameters between sestamibi and {sup 82}Rb MPI. (orig.)

  18. r-CBF brain SPET before surgery and during subthalamic nuclei (STN) high frequency stimulation (DBS) in Parkinson's Disease

    International Nuclear Information System (INIS)

    Gerundini, P.; Benti, R.; De Notaris, A.; Ferrari, M.; Raimondi, A.; Mariani, C.; Antonini, A.; Pezzoli, G.; Gaini, S.M.

    2002-01-01

    Deep brain stimulation (DBS) of the subthalamic nuclei (STN) can improve motor symptoms and reduces the need for medical therapy in severe Parkinson's Disease (PD). Moreover, DBS can affect, as the medical treatment, cerebral perfusion/metabolism even in cortical/subcortical areas not primarily involved in PD motor symptoms. Aim of the study was the assessment of r-CBF changes by mean of brain SPECT in severe PD .before surgery and during DBS of the STN. Methods. 14 PD patients (duration 15.2±5.1 ys; H and Y off-score 3.6±0.7) underwent STN electrode implantation. Residual motor dysfunction was assessed by UPDRS score up to one year after surgery. SPECT was performed after i.v. injection of Tc-99m ECD (740 MBq) in PD group before and 6-9 months after surgery and in 13 age matched normals. Standardized ROIs templates were applied in brain sections to generate perfusion ratios in the cerebral cortex and basal ganglia. Statistical Parametric Mapping (SPM) analysis of SPET studies was also obtained. Results: 6 months after surgery the mean UPDRS score improvement was 48.8±26.1% (DBS on) vs pre surgery. 8 patients (R+) had UPDRS improvement >50% (mean 67.7±8.8%); 6 patients (R-) had score improvement <50% (mean 22.9±18.9%). Before surgery, motor dysfunction during therapy was similar in R+ and R- groups (mean UPDRS 19.8±8.2 vs. 21.3±9.6). During BDS, UPDRS mean score without medical therapy was lower in R+ (15.6±5.6) vs. R- (35.0±12.4; p<0.001). ROIs and SPM analysis of pre-surgery SPET studies showed significant hypoperfusion (p<0.01) in the occipital gyri of PD vs control groups. No significant differences were found by comparing pre/post surgery SPECT patterns in whole PD group. However, in R- group SPECT showed significant hypoperfusion in pre-frontal areas, parietal and occipital gyri vs R+ patients (p<0.02) and controls (p<0.01). Before surgery, R+ group had borderline occipital hypoperfusion (p=0.04) and mild increase of putaminal perfusion (p=0.03) vs

  19. 123I-labeling and evaluation of Ro 43-0463, a SPET tracer for MAO-B imaging

    International Nuclear Information System (INIS)

    Beer, H.-F.; Rossetti, I.; Frey, L.D.; Hasler, P.H.; Schubiger, P.A.

    1995-01-01

    Using the copper assisted halogen exchange the MAO-B inhibitor Ro 43-0463, N-(2-aminoethyl)-5-iodo-2-pyridinecarboxamide, was labelled with 123 I as well as with 125 I to allow in vitro and in vivo investigations including SPET with healthy volunteers. Ro 43-0463 is known to inhibit reversibly and specifically MAO-B, having an ic 50 of 3 x 10 -8 Mol/L. The labeling in the presence of CuSO 4 and ascorbic acid was optimised, varying time (30 to 105 min), precursor concentration (1-3.5 mg) and temperature (130-200 deg. C). The labeling yield ranged between 60 and 70%. Purification was achieved with Lichrosorb RP-18 (5 μm, 250 x 8 mm) and 1.5 mL/min 0.36 M H 3 PO 4 /EtOH (97(3)) [0.01 M (NH 4 ) 2 HPO 4 ]. After neutralisation and sterile filtration the final activity concentration ranged between 18.5 and 37 MBq/mL. Biodistribution studies showed a brain to blood ratio greater than 1 within 1 h p.i. The main radiation burden calculated from these animal data is to alimentary and excretory organs and the ovaries. Autoradiography was performed using rat brain slices and 5 nM [ 125 I]Ro 43-0463 in TRIS-buffer pH 7.4 for 90 min at 20 deg. C. Its radioactivity pattern corresponds to the known distribution of MAO-B in the rat brain. By displacement with L-deprenyl the highly specific binding of Ro 43-0463 was proven in vitro. SPECT studies with normal volunteers corresponded with the pattern found in autoradiography

  20. Effect of age and gender on dopamine transporter imaging with [123I]FP-CIT SPET in healthy volunteers

    International Nuclear Information System (INIS)

    Lavalaye, J.; Booij, J.; Reneman, L.; Habraken, J.B.A.; Royen, E.A. van

    2000-01-01

    Dopamine transporter imaging is a valuable tool to investigate the integrity of the dopaminergic neurons. To date, several reports have shown an age-associated decline in dopamine transporters in healthy volunteers. Although animal studies suggest an effect of gender on dopamine transporter density, this gender effect has not yet been confirmed in human studies. To study the influence of age and gender on dopamine transporter imaging in healthy volunteers, we performed single-photon emission tomography imaging with [ 123 I]FP-CIT to quantify dopamine transporters. Forty-five healthy volunteers (23 males and 22 females) were included, ranging in age from 18 to 83 years. SPET imaging was performed 3 h after injection of ±110 MBq [ 123 I]FP-CIT. An operator-independent volume of interest analysis was used for quantification of [ 123 I]FP-CIT binding in the striatum. The ratio of specific striatal to non-specific [ 123 I]FP-CIT binding was found to decrease significantly with age. Moreover, we found a high variance in [ 123 I]FP-CIT binding in young adults. Finally, females were found to have significantly higher [ 123 I]FP-CIT binding ratios than males. This effect of gender on [ 123 I]FP-CIT binding ratios was not related to age. The results of this study are consistent with findings from previous studies, which showed that dopamine transporter density declines with age. The intriguing finding of a higher dopamine transporter density in females than in males is in line with findings from animal studies. (orig.)

  1. Early detection of the no-reflow phenomenon in reperfused acute myocardial infarction using technetium-99m tetrofosmin imaging

    Energy Technology Data Exchange (ETDEWEB)

    Hamada, Shinichi; Nakamura, Seishi; Murakami, Takashi; Fujimoto, Toshinori; Watanabe, Junko; Baden, Masato [Division of Cardiology, Takarazuka Hospital, Hyogo (Japan); Sugiura, Tetsuro; Hatada, Kengo; Iwasaka, Toshiji [Cardiovascular Center, Kansai Medical University, Osaka (Japan)

    1999-03-01

    Evaluation of myocardial perfusion in the early stage of acute myocardial infarction (MI) is clinically important for adjunctive therapies to minimize infarct size. To determine the role of early scintigraphic detection of impaired myocardial reperfusion after primary coronary angioplasty (PTCA) in patients with acute MI, semiquantitative technetium-99m tetrofosmin single-photon emission tomographic (SPET) imaging was performed before primary PTCA (before; area at risk), 60 min after PTCA (after) and at 1 month (1 M; final infarct) in 35 patients with acute MI. The left ventricle was divided into 13 segments and the defect score was calculated as the sum of the perfusion defect of each segment, from 3 (complete defect) to 0 (normal perfusion). A significant myocardial perfusion change after PTCA was defined as a change in the defect score (before minus after PTCA) of {>=}4. The echocardiographic asynergic score was defined as the number of asynergic (severe hypokinetic or akinetic) segments corresponding to the analogous segments on SPET images, and recovery of wall motion was calculated as absolute change in the asynergic score (before PTCA minus 1 M). Among the 35 patients, 15 (43%) had a change in the defect score of <4 (no reflow: group 1) while 20 had a change in the defect score of {>=}4 (reflow: group 2). There were no significant differences between the two groups with respect to the time between admission to PTCA, revascularization time, collateral grade or Thrombolysis in Myocardial Infarction (TIMI) flow grade before PTCA. Despite the lack of a difference in area at risk between the two groups (group 1 = 12.8{+-}4.3 and group 2 = 15.1{+-}4.7), final infarct size in group 1 was significantly larger compared with that in group 2 (8.1{+-}4.3 vs 4.9{+-}3.0, P<0.001). Recovery of wall motion was significantly smaller in group 1 than in group 2 (4.3{+-}1.7 to 3.5{+-}1.5 vs 4.1{+-}2.1 to 1.6{+-}1.6, P<0.001). In conclusion, a small change (<4) in defect score

  2. Iodobenzamide SPET in neurological and psychiatric diseases: technical aspects and clinical impact; Tomoscintigraphie cerebrale a l`iodobenzamide en pathologie neuropsychiatrique: technique et pertinence clinique

    Energy Technology Data Exchange (ETDEWEB)

    Tranquart, F.; Prunier-Levillion, C.; Guilloteau, D.; Toffol, B. de; Autret, A.; Besnard, J.C.; Baulieu, J.L. [Hopital Bretonneau, 37 - Tours (France)

    1996-12-31

    Cerebral dopamine receptor assessment using single photon emission tomography (SPET) was recently accepted as a valuable method for a relative quantification of these receptors. We have performed 45 examinations using iodobenzamide (123-IBZM), which is a ligand for post-synaptic D2 receptors, in a variety of neurological or psychiatric diseases in which the dopaminergic system could be involved. The relative quantification of these D2 receptors was performed using different ratios with striatal, cerebellar and total tracer uptake. We observed a significant decrease in 123-IBZM striatal tracer uptake in Parkinson`s disease, supra-nuclear palsy, Alzheimer disease or Huntington disease, in comparison with control subjects (p<0.05). The present study indicates that 123-IBZM SPET could be easily performed in the different nuclear medicine departments and is useful in atypical Parkinson`s disease to access the diagnosis and drug efficacy. This could be of prognostic value in suspected or marked Huntington`s disease. (authors). 27 refs., 1 tab., 4 figs.

  3. Gated intracoronary thallium-201 scintigraphy: feasibility and potential clinical advantages

    International Nuclear Information System (INIS)

    Siegel, M.E.; Chen, D.C.; Lee, K.; Rasmussen, D.; Colletti, P.; Thom, P.; Rahimtoola, S.H.

    1989-01-01

    Visualization of ventricular walls with true global motion and myocardial thickening is not possible with use of present scintigraphic techniques. When thallium 201 (201TI) is injected intravenously (IV), only about 5% reaches the myocardium. However, if 201TI is injected intracoronarily, 100% reaches, and approximately 88% localizes in, the myocardium, which results in higher count rates than when given IV, permitting acceptable acquisition times for gated true wall motion studies. The authors describe a new technique using intracoronary (IC) 201TI to acquire high count rate, high contrast, and short acquisition time in gated true wall motion studies. Thirteen patients were studied at rest with gated IC thallium. Six of these patients also had resting IV 201TI myocardial studies. After routine coronary angiography, 0.75 mCi of 201TI was injected into each coronary artery. Multiple sequential one-minute gated studies were obtained in LAO and RAO projections, followed by sequential five-minute images for two hours to determine 201TI redistribution kinetics. Regions of interest over segments of left and right ventricles and background permitted definition of temporal and spatial distributions. Three one-minute gated studies were summed with a total count of 2,100 K for a three-minute acquisition. Myocardium-to-background ratios were as high as 13:1 with a mean of 11.4:1 in the IC study compared with 2.3:1 in the IV studies. Washout half-time in normal myocardium was 95 +/- 5 min. The detectability and size of perfusion defects were different on gated diastolic and systolic, nongated, and IV studies. Questionable defects seen on nongated studies or after IV administration were easily noted on gated diastolic images

  4. Transient myocardial ischemia after myocardial infarction

    DEFF Research Database (Denmark)

    Mickley, H

    1995-01-01

    Ambulatory ST-segment monitoring is a relatively new device in the evaluation of myocardial ischemia. The method is unique in allowing us to continuously examine the patient over an extended period of time in a changing environmental milieu. In survivors of acute myocardial infarction the prevale...

  5. Classification of myocardial infarction

    DEFF Research Database (Denmark)

    Saaby, Lotte; Poulsen, Tina Svenstrup; Hosbond, Susanne

    2013-01-01

    The classification of myocardial infarction into 5 types was introduced in 2007 as an important component of the universal definition. In contrast to the plaque rupture-related type 1 myocardial infarction, type 2 myocardial infarction is considered to be caused by an imbalance between demand...

  6. Evaluation of prognosis in patients with old myocardial infarction

    International Nuclear Information System (INIS)

    Aoki, Riuko; Kawamura, Yasuaki

    1990-01-01

    To evaluate the prognosis in 57 patients with old myocardial infarction, 201 Tl myocardial scintigraphy and 99m Tc-HSA gated blood pool scan had been done as a 5-year follow up study. We subdivided into two groups; group I (over 60 years) and group II (under 60 years). Cardiac index (CI) and right ventricular ejection fraction (RVEF) did not change significantly, however left ventricular ejection fraction (LVEF) changed significantly (p<0.05). Correlationship between CAG score and δLVEF by handgrip exercise test was y=-1.34x+3.61 (n=44, r=-0.400, p<0.01). Otherwise, Tl defect ratio between first and final examination did not show the significant change in two groups. In conclusion, nuclear examination (cardiac function and myocardial blood flow) is significant to evaluate the prognosis in patients with myocardial infarction. (author)

  7. Myocardial imaging. Coxsackie myocarditis

    Energy Technology Data Exchange (ETDEWEB)

    Wells, R.G.; Ruskin, J.A.; Sty, J.R.

    1986-09-01

    A 3-week-old male neonate with heart failure associated with Coxsackie virus infection was imaged with Tc-99m PYP and TI-201. The abnormal imaging pattern suggested myocardial infarction. Autopsy findings indicated that the cause was myocardial necrosis secondary to an acute inflammatory process. Causes of abnormal myocardial uptake of Tc-99m PYP in pediatrics include infarction, myocarditis, cardiomyopathy, bacterial endocarditis, and trauma. Myocardial imaging cannot provide a specific cause diagnosis. Causes of myocardial infarction in pediatrics are listed in Table 1.

  8. Myocardial imaging. Coxsackie myocarditis

    International Nuclear Information System (INIS)

    Wells, R.G.; Ruskin, J.A.; Sty, J.R.

    1986-01-01

    A 3-week-old male neonate with heart failure associated with Coxsackie virus infection was imaged with Tc-99m PYP and TI-201. The abnormal imaging pattern suggested myocardial infarction. Autopsy findings indicated that the cause was myocardial necrosis secondary to an acute inflammatory process. Causes of abnormal myocardial uptake of Tc-99m PYP in pediatrics include infarction, myocarditis, cardiomyopathy, bacterial endocarditis, and trauma. Myocardial imaging cannot provide a specific cause diagnosis. Causes of myocardial infarction in pediatrics are listed in Table 1

  9. Gated community Na Krutci

    Czech Academy of Sciences Publication Activity Database

    Hnídková, Vendula

    2012-01-01

    Roč. 91, č. 12 (2012), s. 750-752 ISSN 0042-4544 Institutional support: RVO:68378033 Keywords : Gated community * Czech contemporary architecture * Kuba Pilař Subject RIV: AL - Art, Architecture , Cultural Heritage

  10. Reversible gates and circuits descriptions

    Science.gov (United States)

    Gracki, Krzystof

    2017-08-01

    This paper presents basic methods of reversible circuit description. To design reversible circuit a set of gates has to be chosen. Most popular libraries are composed of three types of gates so called CNT gates (Control, NOT and Toffoli). The gate indexing method presented in this paper is based on the CNT gates set. It introduces a uniform indexing of the gates used during synthesis process of reversible circuits. The paper is organized as follows. Section 1 recalls basic concepts of reversible logic. In Section 2 and 3 a graphical representation of the reversible gates and circuits is described. Section 4 describes proposed uniform NCT gates indexing. The presented gate indexing method provides gate numbering scheme independent of lines number of the designed circuit. The solution for a circuit consisting of smaller number of lines is a subset of solution for a larger circuit.

  11. Acute myocardial infarction: estimation of at-risk and salvaged myocardium at myocardial perfusion SPECT 1 month after infarction.

    Science.gov (United States)

    Romero-Farina, Guillermo; Aguadé-Bruix, Santiago; Candell-Riera, Jaume; Pizzi, M Nazarena; Pineda, Victor; Figueras, Jaume; Cuberas, Gemma; de León, Gustavo; Castell-Conesa, Joan; García-Dorado, David

    2013-11-01

    To estimate at-risk and salvaged myocardium by using gated single photon emission computed tomography (SPECT) myocardial perfusion imaging after acute myocardial infarction (AMI). The study was approved by the hospital's Ethical Committee on Clinical Trials (trial register number, PR(HG)36/2000), and all patients gave informed consent. Forty patients (mean age, 61.78 years; eight women) with a first AMI underwent two gated SPECT examinations--one before percutaneous coronary intervention (PCI) and one 4-5 weeks after PCI. Myocardium at risk was estimated by assessing the perfusion defect at the first gated SPECT examination, and salvaged myocardium was estimated by assessing the risk area minus necrosis at the second examination. Myocardium at risk was estimated by determining the discordance between the areas of left ventricular (LV) wall motion and perfusion at the second examination. Concordance between tests was analyzed by means of linear regression analysis, the Pearson correlation, the intraclass correlation coefficient, and Bland-Altman analysis. An improvement in perfusion, wall motion, wall thickening, and LV ejection fraction (P Myocardial perfusion gated SPECT performed 1 month after early PCI in a first AMI provides potentially useful information on at-risk and salvaged myocardium. http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.13122324/-/DC1. RSNA, 2013

  12. Advanced insulated gate bipolar transistor gate drive

    Science.gov (United States)

    Short, James Evans [Monongahela, PA; West, Shawn Michael [West Mifflin, PA; Fabean, Robert J [Donora, PA

    2009-08-04

    A gate drive for an insulated gate bipolar transistor (IGBT) includes a control and protection module coupled to a collector terminal of the IGBT, an optical communications module coupled to the control and protection module, a power supply module coupled to the control and protection module and an output power stage module with inputs coupled to the power supply module and the control and protection module, and outputs coupled to a gate terminal and an emitter terminal of the IGBT. The optical communications module is configured to send control signals to the control and protection module. The power supply module is configured to distribute inputted power to the control and protection module. The control and protection module outputs on/off, soft turn-off and/or soft turn-on signals to the output power stage module, which, in turn, supplies a current based on the signal(s) from the control and protection module for charging or discharging an input capacitance of the IGBT.

  13. CT imaging features and frequency of left ventricular myocardial fat in patients with CT findings of chronic left ventricular myocardial infarction

    International Nuclear Information System (INIS)

    Zafar, H.M.; Litt, H.I.; Torigian, D.A.

    2008-01-01

    Aim: To determine the frequency of left ventricular myocardial fat in patients with computed tomography (CT) findings of chronic left ventricular myocardial infarction, and to review the typical CT imaging features. Materials and methods: A retrospective search of the CT and nuclear scintigraphy reports from 1998-2005 for chronic left ventricular myocardial infarction was performed. The study group comprised those cases with available CT examinations revealing findings of chronic left ventricular myocardial infarction. Assessment for the presence of various imaging characteristics of left ventricular myocardial fat was performed in all cases. Results: The frequency of left ventricular myocardial fat in 47 patients with CT evidence of chronic left ventricular myocardial infarction was 51%. Typical CT imaging features include thin linear or curvilinear fat attenuation within left ventricular myocardium, most commonly subendocardial, often associated with left ventricular wall thinning and/or calcification, predominantly in elderly men. Conclusions: Fat in the left ventricular myocardium is a common additional finding in patients with CT findings of chronic left ventricular myocardial infarction. The potential, but as yet unproven, use of this CT imaging finding is that the radiologist may be able to suggest a potential diagnosis of chronic left ventricular myocardial infarction on unenhanced, thick-section, non-gated or non-triggered chest CT imaging where identification of myocardial wall thinning may be difficult

  14. The human respiratory gate

    Science.gov (United States)

    Eckberg, Dwain L.

    2003-01-01

    Respiratory activity phasically alters membrane potentials of preganglionic vagal and sympathetic motoneurones and continuously modulates their responsiveness to stimulatory inputs. The most obvious manifestation of this 'respiratory gating' is respiratory sinus arrhythmia, the rhythmic fluctuations of electrocardiographic R-R intervals observed in healthy resting humans. Phasic autonomic motoneurone firing, reflecting the throughput of the system, depends importantly on the intensity of stimulatory inputs, such that when levels of stimulation are low (as with high arterial pressure and sympathetic activity, or low arterial pressure and vagal activity), respiratory fluctuations of sympathetic or vagal firing are also low. The respiratory gate has a finite capacity, and high levels of stimulation override the ability of respiration to gate autonomic responsiveness. Autonomic throughput also depends importantly on other factors, including especially, the frequency of breathing, the rate at which the gate opens and closes. Respiratory sinus arrhythmia is small at rapid, and large at slow breathing rates. The strong correlation between systolic pressure and R-R intervals at respiratory frequencies reflects the influence of respiration on these two measures, rather than arterial baroreflex physiology. A wide range of evidence suggests that respiratory activity gates the timing of autonomic motoneurone firing, but does not influence its tonic level. I propose that the most enduring significance of respiratory gating is its use as a precisely controlled experimental tool to tease out and better understand otherwise inaccessible human autonomic neurophysiological mechanisms.

  15. Transient myocardial ischemia after myocardial infarction

    DEFF Research Database (Denmark)

    Mickley, H

    1995-01-01

    the prevalence of ambulatory or transient myocardial ischemia is lower than in patients with chronic, stable coronary artery disease. A greater proportion of ischemic episodes, however, are silent than in other subgroups with ischemic heart disease. Early after the infarction, transient myocardial ischemia...... exhibits a circadian variation with a peak activity occurring in the late evening hours. Patients with non-Q wave infarction have more transient myocardial ischemia, whereas thrombolytic therapy seems to result in less residual ischemia. Exercise testing is more sensitive than ambulatory monitoring...

  16. Early and Delayed Myocardial Enhancement in Myocardial Infarction Using Two-Phase Contrast-Enhanced Multidetector-Row CT

    International Nuclear Information System (INIS)

    Ko, Sung-Min; Kim, Young-Whan; Han, Seong-Wook; Seo, Joon-Beom

    2007-01-01

    The purpose of this study was to describe the myocardial enhancement patterns in patients with myocardial infarction using two-phase contrast enhanced multidetector-row computed tomography (MDCT). Twenty-three patients with clinically proven myocardial infarction (17 acute myocardial infarction [AMI] and 6 chronic myocardial infarction [CMI]) were examined with two-phase contrast-enhanced ECG-gated MDCT. The presence, location, and patterns of myocardial enhancement on two phase MDCT images were compared with infarcted myocardial territories determined by using electrocardiogram, echocardiography, thallium-201 single photon emission computed tomography, catheter and MDCT coronary angiography. After clinical assessment, the presence of myocardial infarctions were found in 27 territories (19 AMI and 8 CMI) of 23 patients. Early perfusion defects were observed in 30 territories of all 23 patients. Three territories not corresponding to a myocardial infarction were detected in three patients with AMI and were associated with artifacts. Fourteen of perfusion defects were in the left anterior descending artery territory, four in the left circumflex artery territory, and nine in the right coronary artery territory. Delayed enhancement was observed in 25 territories (17 AMI and 8 CMI) of 21 patients. Delayed enhancement patterns were variable. Transmural early perfusion defects (n =12) were closely associated with transmural late enhancement (n = 5) and subendocardial residual defect with subepicardial late enhancement (n = 5). Myocardial infarction showed early perfusion defects and variable delayed enhancement patterns on two-phase contrast-enhanced MDCT. Delayed enhancement technique of MDCT could provide additional information of the location and extent of infarcted myocardium, and could be useful to plan appropriate therapeutic strategies in patients with AMI

  17. Investigation into the mechanisms of vagus nerve stimulation for the treatment of intractable epilepsy, using {sup 99m}Tc-HMPAO SPET brain images

    Energy Technology Data Exchange (ETDEWEB)

    Barnes, Anna; Chisholm, Jennifer A.; Patterson, James; Wyper, David [Department of Clinical Physics, Institute of Neurological Sciences, Southern General Hospital, 1345 Govan Road, Glasgow G51 4TF (United Kingdom); Duncan, Roderick [Department of Neurology, Institute of Neurological Sciences, Southern General Hospital, Glasgow (United Kingdom); Lindsay, Kenneth [Department of Neurosurgery, Institute of Neurological Sciences, Southern General Hospital, Glasgow (United Kingdom)

    2003-02-01

    Vagus nerve stimulation (VNS) has gained recognition as a treatment for refractory epilepsies where surgical treatment is not possible. While it appears that this treatment is effective in some patients, the mechanism of action is not clearly understood. The purpose of this study was to clarify findings of other positron emission tomography and single-photon emission tomography (SPET) investigations by measuring the acute effect of VNS on patients who have normal cerebral anatomy on magnetic resonance imaging and who have not previously been exposed to VNS. We investigated six subjects (two males and four females, mean age 29.5 years, range 21-39 years) with intractable epilepsy. One patient had primary generalised epilepsy causing generalised tonic-clonic seizures; the remaining five patients had localisation-related epilepsy causing complex partial seizures. SPET imaging was performed using 250 MBq of {sup 99m}Tc-HMPAO and a four-scan paradigm - two with and two without stimulation. The stimulation began at VNS current levels of 0.25 mA and was increased according to the limit of patients' tolerance, usually defined by coughing or discomfort. The stimulating waveform was of continuous square wave pulses of 500 {mu}s duration at 30 Hz. Image analysis was by SPM99. Reduced perfusion during stimulation was observed in the ipsilateral brain stem, cingulate, amygdala and hippocampus and contralateral thalamus and cingulate. The study provides further evidence of the involvement of the limbic system in the action of vagal nerve stimulation. (orig.)

  18. Memory functions and rCBF {sup 99m}Tc-HMPAO SPET: developing diagnostics in Alzheimer's disease

    Energy Technology Data Exchange (ETDEWEB)

    Elgh, Eva; Naesman, Birgitta [Department of Community Medicine and Rehabilitation, Geriatric Medicine, Umeaa University, 901 85 Umeaa (Sweden); Sundstroem, Torbjoern; Aahlstroem, Katrine Riklund [Department of Radiation Sciences, Diagnostic Radiology, Umeaa University, Umeaa (Sweden); Nyberg, Lars [Department of Psychology, Umeaa University, Umeaa (Sweden)

    2002-09-01

    Alzheimer's disease (AD) is a primary degenerative disease of the brain. The prevalence increases with age, with devastating consequences for the individual and society. The aim of this study was to evaluate whether patients with early AD show an altered regional cerebral blood flow (rCBF) compared with control persons. Furthermore, we aimed to investigate the correlation between rCBF in sublobar volumes of the brain and performance on memory tests. Memory tests were chosen to evaluate episodic and semantic memory. Fourteen patients (aged 75.2{+-}8.8 years) with early AD and 15 control persons (aged 71.4{+-}3.2 years) were included. rCBF measurements with single-photon emission tomography (SPET) using technetium-99m hexamethylpropylene amine oxime (HMPAO) were performed. The rCBF {sup 99m}Tc-HMPAO SPET images were spatially transformed to fit a brain atlas and normalised for differences in rCBF (Computerised Brain Atlas software). Cortical and subcortical volumes of interest (VOIs) were analysed and compared. Compared with the controls, AD patients showed a significantly lower rCBF ratio in temporoparietal regions, including the left hippocampus. The diagnostic sensitivity and specificity for AD were high in temporoparietal regions. AD patients had significantly reduced performance on semantic and, in particular, episodic memory tests compared with age-matched normative data, and their performance on several episodic tests correlated with rCBF ratios in parietal and temporal regions, including the left hippocampus. The correlation between rCBF ratio and level of episodic memory performance suggests that abnormalities in rCBF pattern underlie impaired episodic memory functioning in AD. (orig.)

  19. Effect of scatter correction on the compartmental measurement of striatal and extrastriatal dopamine D{sub 2} receptors using [{sup 123}I]epidepride SPET

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, Masahiro; Seneca, Nicholas; Innis, Robert B. [Department of Psychiatry, Yale University School of Medicine and VA Connecticut Healthcare System, West Haven, CT (United States); Molecular Imaging Branch, National Institute of Mental Health, Bethesda, MD (United States); Varrone, Andrea [Department of Psychiatry, Yale University School of Medicine and VA Connecticut Healthcare System, West Haven, CT (United States); Biostructure and Bioimaging Institute, National Research Council, Napoli (Italy); Kim, Kyeong Min; Watabe, Hiroshi; Iida, Hidehiro [Department of Investigative Radiology, National Cardiovascular Center Research Institute, Osaka (Japan); Zoghbi, Sami S. [Department of Psychiatry, Yale University School of Medicine and VA Connecticut Healthcare System, West Haven, CT (United States); Molecular Imaging Branch, National Institute of Mental Health, Bethesda, MD (United States); Department of Radiology, Yale University School of Medicine and VA Connecticut Healthcare System, West Haven, CT (United States); Tipre, Dnyanesh [Molecular Imaging Branch, National Institute of Mental Health, Bethesda, MD (United States); Seibyl, John P. [Institute for Neurodegenerative Disorders, New Haven, CT (United States)

    2004-05-01

    Prior studies with anthropomorphic phantoms and single, static in vivo brain images have demonstrated that scatter correction significantly improves the accuracy of regional quantitation of single-photon emission tomography (SPET) brain images. Since the regional distribution of activity changes following a bolus injection of a typical neuroreceptor ligand, we examined the effect of scatter correction on the compartmental modeling of serial dynamic images of striatal and extrastriatal dopamine D{sub 2} receptors using [{sup 123}I]epidepride. Eight healthy human subjects [age 30{+-}8 (range 22-46) years] participated in a study with a bolus injection of 373{+-}12 (354-389) MBq [{sup 123}I]epidepride and data acquisition over a period of 14 h. A transmission scan was obtained in each study for attenuation and scatter correction. Distribution volumes were calculated by means of compartmental nonlinear least-squares analysis using metabolite-corrected arterial input function and brain data processed with scatter correction using narrow-beam geometry {mu} (SC) and without scatter correction using broad-beam {mu} (NoSC). Effects of SC were markedly different among brain regions. SC increased activities in the putamen and thalamus after 1-1.5 h while it decreased activity during the entire experiment in the temporal cortex and cerebellum. Compared with NoSC, SC significantly increased specific distribution volume in the putamen (58%, P=0.0001) and thalamus (23%, P=0.0297). Compared with NoSC, SC made regional distribution of the specific distribution volume closer to that of [{sup 18}F]fallypride. It is concluded that SC is required for accurate quantification of distribution volumes of receptor ligands in SPET studies. (orig.)

  20. A comparison of 99mTc-HMPAO SPET changes in dementia with Lewy bodies and Alzheimer's disease using statistical parametric mapping

    International Nuclear Information System (INIS)

    Colloby, Sean J.; Paling, Sean M.; Lobotesis, Kyriakos; Ballard, Clive; McKeith, Ian; O'Brien, John T.; Fenwick, John D.; Williams, David E.

    2002-01-01

    Differences in regional cerebral blood flow (rCBF) between subjects with Alzheimer's disease (AD), dementia with Lewy bodies (DLB) and healthy volunteers were investigated using statistical parametric mapping (SPM99). Forty-eight AD, 23 DLB and 20 age-matched control subjects participated. Technetium-99m hexamethylpropylene amine oxime (HMPAO) brain single-photon emission tomography (SPET) scans were acquired for each subject using a single-headed rotating gamma camera (IGE CamStar XR/T). The SPET images were spatially normalised and group comparison was performed by SPM99. In addition, covariate analysis was undertaken on the standardised images taking the Mini Mental State Examination (MMSE) scores as a variable. Applying a height threshold of P≤0.001 uncorrected, significant perfusion deficits in the parietal and frontal regions of the brain were observed in both AD and DLB groups compared with the control subjects. In addition, significant temporoparietal perfusion deficits were identified in the AD subjects, whereas the DLB patients had deficits in the occipital region. Comparison of dementia groups (height threshold of P≤0.01 uncorrected) yielded hypoperfusion in both the parietal [Brodmann area (BA) 7] and occipital (BA 17, 18) regions of the brain in DLB compared with AD. Abnormalities in these areas, which included visual cortex and several areas involved in higher visual processing and visuospatial function, may be important in understanding the visual hallucinations and visuospatial deficits which are characteristic of DLB. Covariate analysis indicated group differences between AD and DLB in terms of a positive correlation between cognitive test score and temporoparietal blood flow. In conclusion, we found evidence of frontal and parietal hypoperfusion in both AD and DLB, while temporal perfusion deficits were observed exclusively in AD and parieto-occipital deficits in DLB. (orig.)

  1. A comparison of {sup 99m}Tc-HMPAO SPET changes in dementia with Lewy bodies and Alzheimer's disease using statistical parametric mapping

    Energy Technology Data Exchange (ETDEWEB)

    Colloby, Sean J.; Paling, Sean M.; Lobotesis, Kyriakos; Ballard, Clive; McKeith, Ian; O' Brien, John T. [Wolfson Research Centre, Institute for Ageing and Health, Newcastle upon Tyne (United Kingdom); Fenwick, John D. [Regional Medical Physics Department, Newcastle General Hospital, Newcastle upon Tyne (United Kingdom); Williams, David E. [Regional Medical Physics Department, Sunderland Royal Hospital (United Kingdom)

    2002-05-01

    Differences in regional cerebral blood flow (rCBF) between subjects with Alzheimer's disease (AD), dementia with Lewy bodies (DLB) and healthy volunteers were investigated using statistical parametric mapping (SPM99). Forty-eight AD, 23 DLB and 20 age-matched control subjects participated. Technetium-99m hexamethylpropylene amine oxime (HMPAO) brain single-photon emission tomography (SPET) scans were acquired for each subject using a single-headed rotating gamma camera (IGE CamStar XR/T). The SPET images were spatially normalised and group comparison was performed by SPM99. In addition, covariate analysis was undertaken on the standardised images taking the Mini Mental State Examination (MMSE) scores as a variable. Applying a height threshold of P{<=}0.001 uncorrected, significant perfusion deficits in the parietal and frontal regions of the brain were observed in both AD and DLB groups compared with the control subjects. In addition, significant temporoparietal perfusion deficits were identified in the AD subjects, whereas the DLB patients had deficits in the occipital region. Comparison of dementia groups (height threshold of P{<=}0.01 uncorrected) yielded hypoperfusion in both the parietal [Brodmann area (BA) 7] and occipital (BA 17, 18) regions of the brain in DLB compared with AD. Abnormalities in these areas, which included visual cortex and several areas involved in higher visual processing and visuospatial function, may be important in understanding the visual hallucinations and visuospatial deficits which are characteristic of DLB. Covariate analysis indicated group differences between AD and DLB in terms of a positive correlation between cognitive test score and temporoparietal blood flow. In conclusion, we found evidence of frontal and parietal hypoperfusion in both AD and DLB, while temporal perfusion deficits were observed exclusively in AD and parieto-occipital deficits in DLB. (orig.)

  2. Adenosine technetium-99m sestamibi single-photon emission tomography for the assessment of jeopardized myocardium early after acute myocardial infarction. Paradoxical scintigraphic underestimation of jeopardized myocardium in patients with a severe infarct-related stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Claeys, M.J.; Rademakers, F.E.; Vrints, C.J.; Snoeck, J.P. [Department of Cardiology, Antwerp University Hospital, Edegem (Belgium); Blockx, P.P. [Department of Nuclear Medicine, Antwerp University Hospital, Edegem (Belgium)

    1997-09-01

    In 51 patients with a recent (<1 month) myocardial infarction, adenosine {sup 99m}Tc-sestamibi single-photon emission tomography (SPET) and dobutamine stress echocardiography (DSE) were performed and correlated with the presence of significant coronary artery stenosis on quantitative coronary angiography. Regional perfusion activity was analysed semi-quantitatively (score 0-4) on a 13-segment left ventricular model. DSE was used for the estimation of the infarct size (low-dose DSE) and for concomitant evaluation of ischaemia (high-dose DSE). A reversible perfusion defect within the infarct region was observed in 20 of the 37 patients with a significant infarct-related lesion (sensitivity of 54%) and only in one patient without a significant infarct-related lesion (specificity of 93%). Further analysis revealed that the scintigraphic assessment of jeopardized myocardium was fairly good in patients with a moderate (DS 51%-64%) infarct-related stenosis but was inadequate in patients with a severe (DS{>=}65%) infarct-related stenosis, while the echocardiographic detection of ischaemia was not influenced by stenosis severity (sensitivity of 73% in both subgroups). This scintigraphic underestimation of jeopardized myocardium was mainly related to a severely impaired myocardial perfusion under baseline conditions, as was evidenced by a significantly more severe rest perfusion score in the infarct region in patients with a severe stenosis as compared to those with a moderate stenosis, while infarct size on echocardiography was similar for both subgroups. It may be concluded that early after an acute myocardial infarction, adenosine {sup 99m}Tc-sestamibi SPET may underestimate reperfused but still jeopardized myocardium, particularly in patients with a severe infarct-related stenosis. In these patients the evaluation of the ischaemic burden on rest-stress scintigraphy is hampered by the presence of a severely impaired myocardial perfusion in resting conditions. (orig

  3. Spin gating electrical current

    Science.gov (United States)

    Ciccarelli, C.; Zârbo, L. P.; Irvine, A. C.; Campion, R. P.; Gallagher, B. L.; Wunderlich, J.; Jungwirth, T.; Ferguson, A. J.

    2012-09-01

    The level of the chemical potential is a fundamental parameter of the electronic structure of a physical system, which consequently plays an important role in defining the properties of active electrical devices. We directly measure the chemical potential shift in the relativistic band structure of the ferromagnetic semiconductor (Ga,Mn)As, controlled by changes in its magnetic order parameter. Our device comprises a non-magnetic aluminum single electron channel capacitively coupled to the (Ga,Mn)As gate electrode. The chemical potential shifts of the gate are directly read out from the shifts in the Coulomb blockade oscillations of the single electron transistor. The experiments introduce a concept of spin gating electrical current. In our spin transistor spin manipulation is completely removed from the electrical current carrying channel.

  4. Extraction of left ventricular myocardial mass from dynamic 11C-acetate PET

    DEFF Research Database (Denmark)

    Harms, Hans; Tolbod, Lars Poulsen; Hansson, Nils Henrik

    11C-acetate 27-min PET scan on a GE Discovery ST PET/CT scanner. Parametric images of uptake rate K1 and both arterial (VA) and venous (VV) spillover fractions were generated using a basis function implementation of the standard single tissue compartment model using non-gated dynamic data. The LV......-gated dynamic 11C-acetate scan. This greatly simplifies both the scanning protocol and data analysis required for calculation of LV myocardial external efficiency....

  5. Gated listmode acquisition with the QuadHIDAC animal PET to image mouse hearts

    International Nuclear Information System (INIS)

    Schaefers, K.P.; Lang, N.; Stegger, L.; Schober, O.; Schaefers, M.

    2006-01-01

    Purpose: the aim of this study was to develop ECG and respiratory gating in combination with listmode acquisition for the quadHIDAC small-animal PET scanner. Methods: ECG and respiratory gating was realized with the help of an external trigger device (BioVET) synchronized with the listmode acquisition. Listmode data of a mouse acquisition (injected with 6.5 MBq of 18 F-FDG) were sorted according to three different gating definitions: 12 cardiac gates, 8 respiratory gates and a combination of 8 cardiac and 8 respiratory gates. Images were reconstructed with filtered back-projection (ramp filter), and parameters like left ventricular wall thickness (WT), wall-to-wall separation (WS) and blood to myocardium activity ratios (BMR) were calculated. Results: cardiac gated images show improvement of all parameters (WT 2.6 mm, WS 4.1 mm, BRM 2.3) in diastole compared to ungated images (WT 3.0 mm, WS 3.4 mm, BMR 1.3). Respiratory gating had little effect on calculated parameters. Conclusion: ECG gating with the quadHIDAC can improve myocardial image quality in mice. This could have a major impact on the calculation of an image-derived input function for kinetic modelling. (orig.)

  6. Estimation of myocardial blood flow and myocardial flow reserve by 99mTc-sestamibi imaging: comparison with the results of [15O]H2O PET

    International Nuclear Information System (INIS)

    Ito, Yoshinori; Noriyasu, Kazuyuki; Kohya, Tetsuro; Kitabatake, Akira; Katoh, Chietsugu; Kuge, Yuji; Furuyama, Hideto; Morita, Koichi; Tamaki, Nagara

    2003-01-01

    We developed a noninvasive method to quantitatively estimate the myocardial blood flow (MBF) index and flow reserve (MFR) using dynamic and static data obtained with technetium-99m sestamibi, and compared the results with MBF and MFR measured by oxygen-15-labeled water ([ 15 O]H 2 O) PET. Twenty patients with coronary artery disease (CAD) and nine normal subjects underwent both 99m Tc-sestamibi and PET studies within 2 weeks. From the anterior view, dynamic data were acquired for 2 min immediately after the injection of 99m Tc-sestamibi, and planar static images were also obtained after 5 min at rest and during ATP stress (0.16 mg kg -1 min -1 for 5 min) on another day. The area under the time-activity curve on the aortic arch (Aorta ACU), myocardial weight with the SPET image (M), and the myocardial count on the planar image for 1 min (C m ) were obtained. The MBF index (MBFI) was calculated as follows: MBFI=C m /Aorta ACU x 100/M. MFR was measured by dividing the MBFI at ATP stress by MBFI at rest. The MBFI measured by 99m Tc-sestamibi was significantly correlated with MBF obtained using [ 15 O]H 2 O PET (MBFI=13.174+11.732 x MBF, r=0.821, P 99m Tc-sestamibi was well correlated with that obtained using [ 15 O]H 2 O PET, with some underestimation (r=0.845, P 99m Tc-sestamibi in patients with CAD was significantly lower than that in normal subjects (CAD: 1.484±0.256 vs normal: 2.127±0.308, P 99m Tc-sestamibi. This may be useful for the quantitative assessment of CAD, especially in those patients with diffuse coronary disease. (orig.)

  7. Gate valve performance prediction

    International Nuclear Information System (INIS)

    Harrison, D.H.; Damerell, P.S.; Wang, J.K.; Kalsi, M.S.; Wolfe, K.J.

    1994-01-01

    The Electric Power Research Institute is carrying out a program to improve the performance prediction methods for motor-operated valves. As part of this program, an analytical method to predict the stem thrust required to stroke a gate valve has been developed and has been assessed against data from gate valve tests. The method accounts for the loads applied to the disc by fluid flow and for the detailed mechanical interaction of the stem, disc, guides, and seats. To support development of the method, two separate-effects test programs were carried out. One test program determined friction coefficients for contacts between gate valve parts by using material specimens in controlled environments. The other test program investigated the interaction of the stem, disc, guides, and seat using a special fixture with full-sized gate valve parts. The method has been assessed against flow-loop and in-plant test data. These tests include valve sizes from 3 to 18 in. and cover a considerable range of flow, temperature, and differential pressure. Stem thrust predictions for the method bound measured results. In some cases, the bounding predictions are substantially higher than the stem loads required for valve operation, as a result of the bounding nature of the friction coefficients in the method

  8. Evaluation of left ventricular ejection fraction using quantitative gated SPECT (QGS)

    International Nuclear Information System (INIS)

    Musa, M. A. A.

    2010-07-01

    Electrocardiographic ally gated myocardial perfusion SPECT (G SPECT) is a state-of the art technique for the combined evaluation of myocardial perfusion and left ventricular function within a single study. It is currently one of the most commonly performed cardiology procedures in a nuclear medicine department. Automation of the image processing and quantification has made this techniques highly reproducible, practical and user friendly in the clinical setting . In patients with coronary artery disease, gating enhances the diagnostic and prognostic capability of myocardial perfusion imaging provides incremental information over the the perfusion data, and has shown potentials for myocardial viability assessment and sequential follow-up after therapy. Evaluation of the left ventricular (L V) function is important in clinical cardiology. Quantifying the degree and extent of the L V functional abnormalities permits a systematic assessment of the disease process on the myocardial performance. The aim of this thesis is to evaluate left ventricular ejection fraction (LVEF) in patients with no evidence of ischemic response during the stress test. This investigation was carried out in view of the few reports concerning the findings ventricular function with gated SPECT in these situations in the normal population, which is relevant when considering the possibility of myocardial stunning. Method: We prospectively studied 30 selected patients, in difference age and gender. A one-day protocol was used, with injection 555 MBq - 1.11 MBq (15 - 30 mCi) of 99 mTc-M1 B1 at stress and rest. Gated perfusion SPECT was acquired 30 to 60 minutes after radiotracer injection in both condition and processed using QGSPECT software. Difference between stress and rest LVEF was calculated. Result and conclusion: rest LVEF was higher in the stress (exercise) group, A trend line was done in both groups and r-value was (0.9) and p=0.04 in acceptance value. Standard deviation of LVEF also was

  9. The four-gate transistor

    Science.gov (United States)

    Mojarradi, M. M.; Cristoveanu, S.; Allibert, F.; France, G.; Blalock, B.; Durfrene, B.

    2002-01-01

    The four-gate transistor or G4-FET combines MOSFET and JFET principles in a single SOI device. Experimental results reveal that each gate can modulate the drain current. Numerical simulations are presented to clarify the mechanisms of operation. The new device shows enhanced functionality, due to the combinatorial action of the four gates, and opens rather revolutionary applications.

  10. Stanford, Duke, Rice,... and Gates?

    Science.gov (United States)

    Carey, Kevin

    2009-01-01

    This article presents an open letter to Bill Gates. In his letter, the author suggests that Bill Gates should build a brand-new university, a great 21st-century institution of higher learning. This university will be unlike anything the world has ever seen. He asks Bill Gates not to stop helping existing colleges create the higher-education system…

  11. ECG gated magnetic resonance imaging in cardiovascular disease

    International Nuclear Information System (INIS)

    Park, Jae Hyung; Im, Chung Kie; Han, Man Chung; Kim, Chu Wan

    1985-01-01

    Using KAIS 0.15 Tesla resistive magnetic imaging system, ECG gated magnetic resonance (MR) image of various cardiovascular disease was obtained in 10 patients. The findings of MR image of the cardiovascular disease were analysed and the results were as follows: 1. In 6 cases of acquired and congenital cardiac diseases, there were 2 cases of myocardial infarction, 1 case of mitral stenosis and 3 cases of corrected transportation of great vessels. The others were 3 cases of aortic disease and 1 case of pericardial effusion with lymphoma. 2. Myocardial thinning and left ventricular aneurysm were detected in MR images of myocardial infarction. The left atrium was well delineated and enlarged in the case of mitral stenosis. And segmental analysis was possible in the cases of corrected transposition since all cardiac structures were well delineated anatomically. 3. In aortic diseases, the findings of MR image were enlarged lumen, compressed cardiac chambers in ascending aortic aneurysm, intimal flap, enhanced false lumen in dissecting aneurysm and irregular narrowing of aorta with arterial obstruction in Takayasu's arteritis. 4. Pericardial effusion revealed a conspicuous contrast with neighboring mediastinal fat and cardiac wall due to it low signal encircling cardiac wall. 5. ECG gated MR image is an accurate non-invasive imaging modality for the diagnosis of cardiovascular disease and better results of its clinical application are expected in the future with further development in the imaging system and more clinical experiences

  12. Review Paper: Myocardial Rupture After Acute Myocardial Infarction ...

    African Journals Online (AJOL)

    Myocardial rupture complications after acute myocardial infarction are infrequent but lethal. They mainly involve rupture of the ventricular free wall, ventricular septum, papillary muscle, or combined. We compare features of different kinds of myocardial ruptures after acute myocardial infarction by reviewing the clinical ...

  13. Myocardial tomo-scintigraphy; La tomoscintigraphie myocardique

    Energy Technology Data Exchange (ETDEWEB)

    Marie, P.Y. [Centre Hospitalier Universitaire, Service de Medecine Nucleaire, Hopital de Brabois 54 - Nancy (France)

    2007-12-15

    In the last years, cardiac imaging has dramatically developed, with the generalization of Ecg-gated myocardial tomo-scintigraphy (M.T.S.) for nuclear cardiology, but also with the precise assessments of cardiac function and of infarction sequels, which are now provided by cardiac MRI, and with the development of coronary angiography by multi-slices CT. In this setting, M.T.S. remains, however, the reference imaging technique for assessing myocardial ischemia, especially at exercise, the sole stress method which is physiologic and which results may be extrapolated to daily-life conditions. Because of this specific property, M.T.S. should remain a major investigation for assessing and following patients with chronic coronary artery disease in the future. The assessment of myocardial ischemia at stress remains unanimously recommended before any invasive therapeutic or diagnostic intervention, when patients are not or only poorly symptomatic. However, it is also likely that this technique will markedly change in the future. Considerable efforts are indeed dedicated to research and development for hybrid recording systems, PET tracers and PET cameras, and gamma detectors systems using semi-conductors. (author)

  14. Differential alteration of the nigrostriatal dopaminergic system in Wilson's disease investigated with [123I]ss-CIT and high-resolution SPET

    International Nuclear Information System (INIS)

    Barthel, H.; Sorger, D.; Kluge, R.; Kuehn, H.-J.; Wagner, A.; Hermann, W.

    2001-01-01

    Wilson's disease (WD) is a copper deposition disorder which can result in a number of extrapyramidal motoric symptoms such as parkinsonism. Therefore, this study was carried out to investigate, for the first time, nigrostriatal dopaminergic function in WD in relation to different courses and severity of the disease. Using high-resolution single-photon emission tomography (SPET) after administration of 2ss-carbomethoxy-3ss-(4[ 123 I]iodophenyl)tropane ([ 123 I]ss-CIT), striatal dopamine transporters (DAT) were imaged in 43 WD patients and a control group of ten subjects. From the SPET images, specific [ 123 I]ss-CIT binding ratios were obtained for the caudate heads, putamina and entire corpus striatum. In addition, to evaluate a putative dissociation between the caudate and putaminal [ 123 I]ss-CIT binding ratios, the ratio between these binding ratios was calculated (CA/PU ratio). The SPET data were compared with clinical data on the course of the disease (CD), the severity of neurological symptoms and the degree of hepatic alteration. Whereas the specific regional [ 123 I]ss-CIT binding ratios in patients with asymptomatic/hepatic CD did not differ from those in the control group (e.g. striatal ratios: 13.4±3.0 vs 11.7±2.8), in patients with neurological CD the ratios were significantly reduced for all striatal substructures (P=0.003 after one-factor ANOVA). For the different subgroups a tendency was detected towards a stepwise decrease in the specific [ 123 I]ss-CIT binding ratios from pseudo-sclerosis CD (9.4±2.3), through pseudo-parkinsonian CD (9.1±2.1) to arrhythmic-hyperkinetic CD (8.5±1.6). However, these group differences reached significance only for the comparison with asymptomatic/hepatic CD (P=0.02). The CA/PU ratio was significantly higher in WD than in the control group (1.30±0.19 vs 1.11±0.08; P=0.003). Severity of neurological symptoms was significantly correlated with all specific regional [ 123 I]ss-CIT binding ratios (r=-0.49 to -0

  15. The scintigraphic evaluation of myocardial infarction and regional ventricular performance using technetium-99m hexakis (t-butylisonitrile) technetium (I) (TBI): A new myocardial imaging agent

    International Nuclear Information System (INIS)

    Campbell, S.; Kirshenbaum, J.M.; Antman, E.M.; Lister-James, J.; Davison, A.; Kozlowski, J.; English, R.J.; Jones, A.G.; Massachusetts Inst. of Tech., Cambridge; Holman, B.L.

    1986-01-01

    Technetium-99m hexakis (t-butylisonitrile) technetium(I) (sup(99m)Tc-TBI) is a new myocardial perfusion imaging agent. To determine its potential in the evaluation of myocardial infarction, 15 patients with suspected or confirmed acute infarction were studied by beside imaging in the coronary care unit. Good-quality planar scintigrams in multiple projections were obtained in 13 patients. Gated perfusion studies were performed in 14 patients, and for comparison 13 of these were restudied 24-72 h later by standard gated equilibrium blood pool radionuclide ventriculography. Conventional and planar scintigraphic criteria for myocardial infarction (acute or old) agreed in 12 (92%) patients (k=0.81, p<0.05). All the infarcations detected by scintigraphy were associated with electrocardiographic Q-waves. Localization of infarction by the electrocardiogram and scintigraphy exhibited moderate agreement (k=0.49, p<0.1). Regional wall motion analysis by standard radio-nuclide ventriculography and gated sup(99m)Tc-TBI scintigraphy were in complete agreement for 25 (64%) of 39 left ventricular segments (k=0.35, p<0.05). However, in 7 other segments, associated with areas of infarction, regional wall motion abnormalities were noted only on gated sup(99m)Tc-TBI scintigraphy. Therefore, sup(99m)Tc-TBI scintigraphy can readily provide data on regional myocardial perfusion and wall motion, permitting detection and localization of areas of myocardial infarction. The superior imaging properties, ready availability and low cost of sup(99m)Tc point to the considerable potential value of sup(99m)Tc-TBI in assessing patients with suspected or confirmed myocardial infarction. (orig.)

  16. High permittivity gate dielectric materials

    CERN Document Server

    2013-01-01

    "The book comprehensively covers all the current and the emerging areas of the physics and the technology of high permittivity gate dielectric materials, including, topics such as MOSFET basics and characteristics, hafnium-based gate dielectric materials, Hf-based gate dielectric processing, metal gate electrodes, flat-band and threshold voltage tuning, channel mobility, high-k gate stack degradation and reliability, lanthanide-based high-k gate stack materials, ternary hafnia and lanthania based high-k gate stack films, crystalline high-k oxides, high mobility substrates, and parameter extraction. Each chapter begins with the basics necessary for understanding the topic, followed by a comprehensive review of the literature, and ultimately graduating to the current status of the technology and our scientific understanding and the future prospects."

  17. Gadolinium-enhanced magnetic resonance imaging in acute myocardial infarction

    International Nuclear Information System (INIS)

    Dijkman, P.R.M. van; Wall, E.E. van der; Roos, A. de; Doornbos, J.; Laarse, A. van der; Voorthuisen, A.E. van; Bruschke, A.V.G.; Rossum, A.C. van

    1990-01-01

    To evaluate he usefulness of the paramagnetic contrast agent Gadolinium-DTPA (diethylenetriaminepentaacetic acid) in Magnetic Resonance. Imaging of acute myocardial infarction, we studied a total of 45 patients with a first acute myocardial infarction by ECG-gated magnetic resonance imaging before and after intravenous administration of 0.1 mmol/kg Gadolinium-DTPA. All patients received thrombolytic treatment by intravenous streptokinase. The magnetic resonance imaging studies were preformed after a meam of 88 h (range 15-241) after the acute onset of acute myocardial infarction. Five patients without evidence of cardiac disease served as controls. Spin-echo measurements (TE 30 ms) were made using a Philips Gyroscan (0.5 Tesla) or a Teslacon II (0.6 Tesla). The 45 patients were divided into four groups of patients. In Group I( patients) Gadolinium-DTPA improved the detection of myocardial infarction by Gadolinium-DTPA. In Group II (20 patients) the magnetic resonance imaging procedure was repeated every 10 min for up to 40 min following administration of Gadolinium-DTPA. Optimal contrast enhancement was obtained 20-25 min after Gadolinium-DTPA. In Group III (27 patients) signal intensities were significantly higher in the patients who underwent the magnetic resonance imaging study more than 72 h (mean 120) after the acute event, suggesting increased acculumation of Gadolinium-DTPA in a more advanced stage of the infarction process. In Group IV (45 patients) Gadolinium-DTPA was administered in an attempt to distinguish between reperfused and nonreperfused myocardial areas after thrombolytic treatment for acute myocardial infarction. The signal intensities did not differ, but reperfused areas showed a more homogeneous aspect whereas nonreperfused areas were visualized as a more heterogeneous contrast enhancement. It is concluded that magnetic resonance imaging using the contrast agent Gadolinium-DTPA significantly improves the detection of infarcted myocardial areas

  18. Use of 123I-IMP brain SPET to predict outcome following STA-MCA bypass surgery: cerebral blood flow but not vasoreactivity is a predictive parameter

    International Nuclear Information System (INIS)

    Kume, Norihiko; Hayashida, Kohei; Iwama, Toru; Cho, I.; Matsunaga, N.

    1998-01-01

    Superficial temporal artery - middle cerebral artery (STA-MCA) bypass surgery might improve the cerebral blood flow (CBF) but fail to reduce the risk of post-surgical events such as ischaemic stroke. In this study, we studied retrospectively whether the risk of post-surgical events corresponded to the change in resting CBF and/or the change in vasoreactivity observed before and after STA-MCA surgery using N-isopropyl-I-123-p-iodoamphetamine ( 123 I-IMP) brain single-photon emission tomography (SPET). 123 I-IMP brain SPET images obtained at rest and following acetazolamide challenge both before and after STA-MCA surgery were studied in 30 patients. Resting CBF was estimated semiquantitatively using the resting count ratios of the middle cerebral artery (MCA) area to the cerebellum. Acetazolamide challenge was assumed to result in an average increase in flow of 40% in the cerebellum. The vasoreactive response was then estimated as the ratio of the change in counts (acetazolamide - rest) to the resting cerebellar counts multiplied by 1.4. We classified 14 patients (50.5±19.3 years) into group I, who had a change in their resting CBF from before to after surgery of >10%, and 16 patients (54.0±18.8 years) into group II, who had a change in their resting CBF from before to after surgery of ≤10%. Oxygen-15 positron emission tomography (PET) studies were performed in five patients from group I and five patients from group II. One post-surgical event occurred in group I while there were eight post-surgical events in group II (P<0.05). Resting CBF improved by 20.4%±7.5% in group I and by 0.9%±6.9% in group II patients after surgery (P<0.001). No significant difference in the improvement in vasoreactivity was observed between group I patients (32.6%±17.7%) and group II patients (24.6%±15.6%) following surgery. Patients in the group I PET subset showed normalization of oxygen extraction fraction (OEF) from 0.59±0.09 before surgery to 0.46±0.06 after surgery (P<0

  19. FDG-PET, {sup 99m}Tc-HMPAO white blood cell SPET and bone scintigraphy in the evaluation of painful total knee arthroplasties

    Energy Technology Data Exchange (ETDEWEB)

    Van Acker, F.; Nuyts, J.; Maes, A.; Vanquickenborne, B.; Vleugels, S.; Bormans, G.; Mortelmans, L. [Dept. of Nuclear Medicine, University Hospital Gasthuisberg, Leuven (Belgium); Stuyck, J.; Bellemans, J. [Department of Orthopaedic Surgery, University Hospital Pellenberg, Leuven (Belgium)

    2001-10-01

    Fluorine-18 fluorodeoxyglucose positron emission tomography (FDG-PET), technetium-99m hexamethylpropylene amine oxime (HMPAO)-labelled white blood cell (WBC) scintigraphy and bone scintigraphy were used in the evaluation of total knee arthroplasties (TKAs). We prospectively included 21 patients who had a three-phase bone scan for exclusion of infection of TKAs. Four hours after injection of 185 MBq {sup 99m}Tc-HMPAO-labelled WBCs, planar and single-photon emission tomographic (SPET) imaging was performed. Planar imaging was repeated at 24 h p.i. Consecutively images of the knees were obtained with a dedicated PET system 60 min following the injection of 370 MBq of FDG. Focal tracer uptake was scored on SPET and PET visually (0=no uptake, 4=intense uptake). In addition, SUV (standardised uptake value) per voxel was calculated from attenuation-corrected PET images using the MLAA algorithm. Focal uptake at the bone-prosthesis interface was used as the criterion for infection before and after correlation with the third phase of the bone scan. Final diagnosis was based on operative findings, culture and clinical outcome. In the infected TKAs, the WBC scan showed focal activity of grade 2 (n=2), 3 (n=1) or 4 (n=2). PET scan revealed focal activity of grade 4 (n=5) or 3 (n=1). WBC scan alone had a specificity for infection of 53% [positive predictive value (PPV) 42%, sensitivity 100%], compared with 73% for PET scan (PPV 60%, sensitivity 100%). Considering only lesions at the bone-prosthesis interface that were also present on the third phase of the bone scan, we found a specificity of 93% (PPV 83%) for WBC scan. Using these criteria, a specificity of 80% (PPV 67%) was obtained for PET scan. Two out of three false-positive PET scans were due to loosening of the TKA. It is concluded that WBC scintigraphy in combination with bone scintigraphy has a high specificity in the detection of infected TKAs. FDG-PET seems to offer no additional benefit. (orig.)

  20. Anatomically standardised 99mTc-ECD brain perfusion SPET allows accurate differentiation between healthy volunteers, multiple system atrophy and idiopathic Parkinson's disease

    International Nuclear Information System (INIS)

    Bosman, Tommy; Van Laere, Koen; Santens, Patrick

    2003-01-01

    The clinical differentiation between typical idiopathic Parkinson's disease (IPD) and atypical parkinsonian disorders such as multiple system atrophy (MSA) is complicated by the presence of signs and symptoms common to both forms. The goal of this study was to re-evaluate the contribution of brain perfusion single-photon emission tomography (SPET) with anatomical standardisation and automated analysis in the differentiation of IPD and MSA. This was achieved by discriminant analysis in comparison with a large set of age- and gender-matched healthy volunteers. Technetium-99m ethyl cysteinate dimer SPET was performed on 140 subjects: 81 IPD patients (age 62.6±10.2 years; disease duration 11.0±6.4 years; 50 males/31 females), 15 MSA patients (61.5±9.2 years; disease duration 3.0±2.2 years; 9 males/6 females) and 44 age- and gender-matched healthy volunteers (age 59.2±11.9 years; 27 males/17 females). Patients were matched for severity (Hoehn and Yahr stage). Automated predefined volume of interest (VOI) analysis was carried out after anatomical standardisation. Stepwise discriminant analysis with cross-validation using the leave-one-out method was used to determine the subgroup of variables giving the highest accuracy for this differential diagnosis. Between MSA and IPD, the only regions with highly significant differences in uptake after Bonferroni correction were the putamen VOIs. Comparing MSA versus normals and IPD, with putamen VOI values as discriminating variables, cross-validated performance showed correct classification of MSA patients with a sensitivity of 73.3%, a specificity of 84% and an accuracy of 83.6%. Additional input from the right caudate head and the left prefrontal and left mesial temporal cortex allowed 100% discrimination even after cross-validation. Discrimination between the IPD group alone and healthy volunteers was accurate in 94% of the cases after cross-validation, with a sensitivity of 91.4% and a specificity of 100%. The three

  1. Periodontitis and myocardial hypertrophy.

    Science.gov (United States)

    Suzuki, Jun-Ichi; Sato, Hiroki; Kaneko, Makoto; Yoshida, Asuka; Aoyama, Norio; Akimoto, Shouta; Wakayama, Kouji; Kumagai, Hidetoshi; Ikeda, Yuichi; Akazawa, Hiroshi; Izumi, Yuichi; Isobe, Mitsuaki; Komuro, Issei

    2017-04-01

    There is a deep relationship between cardiovascular disease and periodontitis. It has been reported that myocardial hypertrophy may be affected by periodontitis in clinical settings. Although these clinical observations had some study limitations, they strongly suggest a direct association between severity of periodontitis and left ventricular hypertrophy. However, the detailed mechanisms between myocardial hypertrophy and periodontitis have not yet been elucidated. Recently, we demonstrated that periodontal bacteria infection is closely related to myocardial hypertrophy. In murine transverse aortic constriction models, a periodontal pathogen, Aggregatibacter actinomycetemcomitans markedly enhanced cardiac hypertrophy with matrix metalloproteinase-2 activation, while another pathogen Porphyromonas gingivalis (P.g.) did not accelerate these pathological changes. In the isoproterenol-induced myocardial hypertrophy model, P.g. induced myocardial hypertrophy through Toll-like receptor-2 signaling. From our results and other reports, regulation of chronic inflammation induced by periodontitis may have a key role in the treatment of myocardial hypertrophy. In this article, we review the pathophysiological mechanism between myocardial hypertrophy and periodontitis.

  2. Noise Gating Solar Images

    Science.gov (United States)

    DeForest, Craig; Seaton, Daniel B.; Darnell, John A.

    2017-08-01

    I present and demonstrate a new, general purpose post-processing technique, "3D noise gating", that can reduce image noise by an order of magnitude or more without effective loss of spatial or temporal resolution in typical solar applications.Nearly all scientific images are, ultimately, limited by noise. Noise can be direct Poisson "shot noise" from photon counting effects, or introduced by other means such as detector read noise. Noise is typically represented as a random variable (perhaps with location- or image-dependent characteristics) that is sampled once per pixel or once per resolution element of an image sequence. Noise limits many aspects of image analysis, including photometry, spatiotemporal resolution, feature identification, morphology extraction, and background modeling and separation.Identifying and separating noise from image signal is difficult. The common practice of blurring in space and/or time works because most image "signal" is concentrated in the low Fourier components of an image, while noise is evenly distributed. Blurring in space and/or time attenuates the high spatial and temporal frequencies, reducing noise at the expense of also attenuating image detail. Noise-gating exploits the same property -- "coherence" -- that we use to identify features in images, to separate image features from noise.Processing image sequences through 3-D noise gating results in spectacular (more than 10x) improvements in signal-to-noise ratio, while not blurring bright, resolved features in either space or time. This improves most types of image analysis, including feature identification, time sequence extraction, absolute and relative photometry (including differential emission measure analysis), feature tracking, computer vision, correlation tracking, background modeling, cross-scale analysis, visual display/presentation, and image compression.I will introduce noise gating, describe the method, and show examples from several instruments (including SDO

  3. A quantum Fredkin gate.

    Science.gov (United States)

    Patel, Raj B; Ho, Joseph; Ferreyrol, Franck; Ralph, Timothy C; Pryde, Geoff J

    2016-03-01

    Minimizing the resources required to build logic gates into useful processing circuits is key to realizing quantum computers. Although the salient features of a quantum computer have been shown in proof-of-principle experiments, difficulties in scaling quantum systems have made more complex operations intractable. This is exemplified in the classical Fredkin (controlled-SWAP) gate for which, despite theoretical proposals, no quantum analog has been realized. By adding control to the SWAP unitary, we use photonic qubit logic to demonstrate the first quantum Fredkin gate, which promises many applications in quantum information and measurement. We implement example algorithms and generate the highest-fidelity three-photon Greenberger-Horne-Zeilinger states to date. The technique we use allows one to add a control operation to a black-box unitary, something that is impossible in the standard circuit model. Our experiment represents the first use of this technique to control a two-qubit operation and paves the way for larger controlled circuits to be realized efficiently.

  4. Measuring myocardial perfusion

    DEFF Research Database (Denmark)

    Qayyum, A A; Kastrup, J

    2015-01-01

    Recently, focus has changed from anatomical assessment of coronary arteries towards functional testing to evaluate the effect of stenosis on the myocardium before intervention. Besides positron-emission tomography (PET), cardiac MRI (CMR), and cardiac CT are able to measure myocardial perfusion......-known and is used in routine clinical practice. However, PET uses radioactive tracers and has a lower spatial resolution compared to CMR and CT. CMR and CT are emerging techniques in the field of myocardial perfusion imaging. CMR uses magnetic resonance to obtain images, whereas CT uses x-rays during first....... Myocardial perfusion abnormalities are the first sign of the ischaemic cascade in the development of coronary artery disease (CAD). PET is considered the non-invasive clinical reference standard for absolute quantification of myocardial perfusion. The diagnostic and prognostic value of PET is well...

  5. 100-nm gate lithography for double-gate transistors

    Science.gov (United States)

    Krasnoperova, Azalia A.; Zhang, Ying; Babich, Inna V.; Treichler, John; Yoon, Jung H.; Guarini, Kathryn; Solomon, Paul M.

    2001-09-01

    The double gate field effect transistor (FET) is an exploratory device that promises certain performance advantages compared to traditional CMOS FETs. It can be scaled down further than the traditional devices because of the greater electrostatic control by the gates on the channel (about twice as short a channel length for the same gate oxide thickness), has steeper sub-threshold slope and about double the current for the same width. This paper presents lithographic results for double gate FET's developed at IBM's T. J. Watson Research Center. The device is built on bonded wafers with top and bottom gates self-aligned to each other. The channel is sandwiched between the top and bottom polysilicon gates and the gate length is defined using DUV lithography. An alternating phase shift mask was used to pattern gates with critical dimensions of 75 nm, 100 nm and 125 nm in photoresist. 50 nm gates in photoresist have also been patterned by 20% over-exposure of nominal 100 nm lines. No trim mask was needed because of a specific way the device was laid out. UV110 photoresist from Shipley on AR-3 antireflective layer were used. Process windows, developed and etched patterns are presented.

  6. Myocardial perfusion defects and the left ventricular ejection fraction disclosed by scintigraphy in patients with primary hyperparathyroidism

    DEFF Research Database (Denmark)

    Ogard, Christina Gerlach; Søndergaard, Susanne Bonnichsen; Vestergaard, Henrik

    2005-01-01

    Patients with primary hyperparathyroidism (PHPT) have increased risk of cardiovascular disease. For patients undergoing preoperative parathyroid imaging with 99mTc-sestamibi single photon emission computed tomography (SPECT), we combined cervical SPECT and gated cardiac SPECT to achieve information...... about the localization of parathyroid adenomas, myocardial perfusion, and the left ventricular ejection fraction (LVEF) at rest. A series of 22 patients with PHPT and no history of myocardial infarction or angina pectoris were recruited consecutively. At 60 minutes after injection of 700 MBq 99m......Tc-sestamibi, SPECT of the neck and gated myocardial perfusion SPECT were performed at the same time. All of the patients who underwent parathyroidectomy had the parathyroid adenoma localized as predicted from the SPECT. Five patients (23%) had myocardial perfusion defects extending more than 15% (range 15...

  7. Usefulness of contrast enhanced cardiac computed tomography in myocardial infarction

    International Nuclear Information System (INIS)

    Morooka, Nobuhiro; Yamada, Zenju; Watanabe, Shigeru

    1982-01-01

    Contrast enhanced cardiac computed tomography (CECT) was performed in 33 patients with transmural myocardial infarction. The anterior wall thickness assessed by CECT was well correlated with that by left ventriculography in RAO projection. When the septal wall thickness was compared between ECG gated and non-gated CECT images, the septal wall thickness by non-gated CECT showed a close coincidence with the diastolic wall thickness by ECG gated CECT. In all patients, the thickness of the septal, anterior and postero-lateral walls was measured. The mean wall thickness in patients of antero-septal infarction was 9.0 +- 1.9 mm for the septal wall, 6.3 +- 1.3 mm for the anterior wall, and 10.0 +- 2.1 mm for the postero-lateral wall. In patients of infero-lateral infarction, the mean wall thickness was 12.2 +- 1.7 mm for the septal wall, 10.8 +- 1.6 mm for the anterior wall and 8.9 +- 1.2 mm for the postero-lateral wall. A filling defect was revealed in the infarcted area when CECT was performed in patients with acute myocardial infarction within 1 week from the onset, and late enhancement was demonstrated by plain CT performed 10 min later. Left ventricular aneurysms were noted in 16 of 23 patients of anteroseptal infarction, and 8 of these 16 had mural thrombi in the left ventricle. Coronary artery calcification was found in 11 of 33 myocardial infarction patients. In patients with aortocoronary bypass graft, the sequential scan (dynamic scan) was shown to be a useful non-invasive method because it showed whether the graft was patent or not. (J.P.N.)

  8. Expert Oracle GoldenGate

    CERN Document Server

    Prusinski, Ben; Chung, Richard

    2011-01-01

    Expert Oracle GoldenGate is a hands-on guide to creating and managing complex data replication environments using the latest in database replication technology from Oracle. GoldenGate is the future in replication technology from Oracle, and aims to be best-of-breed. GoldenGate supports homogeneous replication between Oracle databases. It supports heterogeneous replication involving other brands such as Microsoft SQL Server and IBM DB2 Universal Server. GoldenGate is high-speed, bidirectional, highly-parallelized, and makes only a light impact on the performance of databases involved in replica

  9. Molecular logic gate arrays.

    Science.gov (United States)

    de Silva, A Prasanna

    2011-03-01

    Chemists are now able to emulate the ideas and instruments of mathematics and computer science with molecules. The integration of molecular logic gates into small arrays has been a growth area during the last few years. The design principles underlying a collection of these cases are examined. Some of these computing molecules are applicable in medical- and biotechnologies. Cases of blood diagnostics, 'lab-on-a-molecule' systems, and molecular computational identification of small objects are included. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Respiratory gating of cardiac PET data in list-mode acquisition.

    Science.gov (United States)

    Livieratos, Lefteris; Rajappan, Kim; Stegger, Lars; Schafers, Klaus; Bailey, Dale L; Camici, Paolo G

    2006-05-01

    Respiratory motion has been identified as a source of artefacts in most medical imaging modalities. This paper reports on respiratory gating as a means to eliminate motion-related inaccuracies in PET imaging. Respiratory gating was implemented in list mode with physiological signal recorded every millisecond together with the PET data. Respiration was monitored with an inductive respiration monitor using an elasticised belt around the patient's chest. Simultaneous ECG gating can be maintained independently by encoding ECG trigger signal into the list-mode data. Respiratory gating is performed in an off-line workstation with gating parameters defined retrospectively. The technique was applied on a preliminary set of patient data with C(15)O. Motion was visually observed in the cine displays of the sagittal and coronal views of the reconstructed respiratory gated images. Significant changes in the cranial-caudal position of the heart could be observed. The centroid of the cardiac blood pool showed an excursion of 4.5-16.5 mm (mean 8.5+/-4.8 mm) in the cranial-caudal direction, with more limited excursion of 1.1-7.0 mm (mean 2.5+/-2.2 mm) in the horizontal direction and 1.3-3.7 mm (mean 2.4+/-0.9 mm) in the vertical direction. These preliminary data show that the extent of motion involved in respiration is comparable to myocardial wall thickness, and respiratory gating may be considered in order to reduce this effect in the reconstructed images.

  11. Role of myocardial perfusion SPECT in asymptomatic diabetic patients

    International Nuclear Information System (INIS)

    Cho, I.; Chun, K.; Won, K.; Lee, H.; Park, J.; Shin, D.; Kim, Y.; Shim, B.; Lee, J.

    2002-01-01

    Purpose: It is important that early diagnosis and treatment of coronary artery disease in diabetic patients, but there are few reports on the prevalence of stress-induced myocardial perfusion abnormalities and the rates of cardiac event in patients with type 2 diabetes. We evaluated the scan findings on gated myocardial perfusion SPECT in asymptomatic diabetic patients. Methods: We performed pharmacological stress test and gated perfusion SPECT in 69 diabetic patients without cardiovascular symptom (mean age: 65 year, male 31 and female 38). Patients underwent two-day imaging protocol and stress study was performed injection of Tc-99m MIBI during adenosine infusion. We followed up these patients by reviewing medical records. Results: Fifty-two of 69 patients (74.5%) showed normal scan findings and 17 patients (24.6%) showed reversible or fixed perfusion defects. Three of 52 patients with normal scan findings showed decreased LV ejection fraction and decreased wall motion. Twenty-three patients with normal scan findings were possible to follow up for more than 1yr (mean time: 18.3±3.3 mo.) and they all had no cardiac event. Three patients with reversible perfusion defects were performed coronary angioplasty. Conclusion: Myocardial perfusion SPECT is a noninvasive method and maybe useful in early diagnosis and predicting prognosis in diabetic patients

  12. Works close to gate B

    CERN Document Server

    GS Department

    2011-01-01

    In connection to the TRAM project, drainage works will be carried out close to gate B until the end of next week. In order to avoid access problems, if arriving by car, please use gates A and E. Department of General Infrastructure Services (GS) GS-SE Group

  13. Penn State DOE GATE Program

    Energy Technology Data Exchange (ETDEWEB)

    Anstrom, Joel

    2012-08-31

    The Graduate Automotive Technology Education (GATE) Program at The Pennsylvania State University (Penn State) was established in October 1998 pursuant to an award from the U.S. Department of Energy (U.S. DOE). The focus area of the Penn State GATE Program is advanced energy storage systems for electric and hybrid vehicles.

  14. GATE: Improving the computational efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Staelens, S. [UGent-ELIS, St-Pietersnieuwstraat, 41, B-9000 Gent (Belgium)]. E-mail: steven.staelens@ugent.be; De Beenhouwer, J. [UGent-ELIS, St-Pietersnieuwstraat, 41, B-9000 Gent (Belgium); Kruecker, D. [Institute of Medicine-Forschungszemtrum Juelich, D-52425 Juelich (Germany); Maigne, L. [Departement de Curietherapie-Radiotherapie, Centre Jean Perrin, F-63000 Clermont-Ferrand (France); Rannou, F. [Departamento de Ingenieria Informatica, Universidad de Santiago de Chile, Santiago (Chile); Ferrer, L. [INSERM U601, CHU Nantes, F-44093 Nantes (France); D' Asseler, Y. [UGent-ELIS, St-Pietersnieuwstraat, 41, B-9000 Gent (Belgium); Buvat, I. [INSERM U678 UPMC, CHU Pitie-Salpetriere, F-75634 Paris (France); Lemahieu, I. [UGent-ELIS, St-Pietersnieuwstraat, 41, B-9000 Gent (Belgium)

    2006-12-20

    GATE is a software dedicated to Monte Carlo simulations in Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET). An important disadvantage of those simulations is the fundamental burden of computation time. This manuscript describes three different techniques in order to improve the efficiency of those simulations. Firstly, the implementation of variance reduction techniques (VRTs), more specifically the incorporation of geometrical importance sampling, is discussed. After this, the newly designed cluster version of the GATE software is described. The experiments have shown that GATE simulations scale very well on a cluster of homogeneous computers. Finally, an elaboration on the deployment of GATE on the Enabling Grids for E-Science in Europe (EGEE) grid will conclude the description of efficiency enhancement efforts. The three aforementioned methods improve the efficiency of GATE to a large extent and make realistic patient-specific overnight Monte Carlo simulations achievable.

  15. GATE: Improving the computational efficiency

    International Nuclear Information System (INIS)

    Staelens, S.; De Beenhouwer, J.; Kruecker, D.; Maigne, L.; Rannou, F.; Ferrer, L.; D'Asseler, Y.; Buvat, I.; Lemahieu, I.

    2006-01-01

    GATE is a software dedicated to Monte Carlo simulations in Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET). An important disadvantage of those simulations is the fundamental burden of computation time. This manuscript describes three different techniques in order to improve the efficiency of those simulations. Firstly, the implementation of variance reduction techniques (VRTs), more specifically the incorporation of geometrical importance sampling, is discussed. After this, the newly designed cluster version of the GATE software is described. The experiments have shown that GATE simulations scale very well on a cluster of homogeneous computers. Finally, an elaboration on the deployment of GATE on the Enabling Grids for E-Science in Europe (EGEE) grid will conclude the description of efficiency enhancement efforts. The three aforementioned methods improve the efficiency of GATE to a large extent and make realistic patient-specific overnight Monte Carlo simulations achievable

  16. MRI of myocardial perfusion.

    Science.gov (United States)

    Jerosch-Herold, Michael; Muehling, Olaf; Wilke, Norbert

    2006-02-01

    An overwhelming number of myocardial perfusion studies are done by nuclear isotope imaging. Magnetic resonance imaging during the first pass of an injected, contrast bolus has some significant advantages for detection of blood flow deficits, namely higher spatial resolution, absence of ionizing radiation, and speed of the test. Previous clinical studies have demonstrated that excellent sensitivity and specificity can be achieved with MR myocardial perfusion imaging for detecting coronary artery disease, and assessment of patients with acute chest pain. Furthermore, an absolute quantification of myocardial blood flow is feasible, as was demonstrated by comparison of MR perfusion imaging, to measurements with isotope labeled microspheres in experimental models. An integrated assessment of perfusion, function, and viability, is thus feasible by MRI to answer important clinical challenges such as the identification of stunned or hibernating, but viable myocardium.

  17. Thallium-201 right lung/heart ratio during exercise in patients with coronary artery disease: relation to thallium-201 myocardial single-photon emission tomography, rest and exercise left ventricular function and coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Morel, O.; Pezard, P.; Le Jeune, J.J.; Denizot, B.; Jallet, P. [Department of Nuclear Medicine, University Hospital, Angers (France); Furber, A. [Department of Cardiology, University Hospital, Angers (France); Vielle, B. [Department of Biostatistics, University Hospital, Angers (France)

    1999-06-01

    The aim of this study was to correlate lung thallium-201 uptake on exercise with {sup 201}Tl single-photon emission tomography (SPET) myocardial perfusion imaging, rest and exercise equilibrium radionuclide angiographic and coronary angiographic findings in patients with coronary artery disease (CAD) using a simple, reproducible lung/heart (L/H) ratio that would be easy to use in clinical practice. L/H ratio was defined on the anterior planar image obtained during exercise {sup 201}Tl SPET acquisition as the mean counts per pixel in an entire right lung field region of interest divided by the mean counts per pixel in the hottest myocardial wall region of interest. We studied 103 patients. Fifty-nine patients (group I) with <5% likelihood of CAD were used as a reference group. In 44 CAD patients (group II), L/H ratio was compared with {sup 201}Tl SPET, radionuclide angiographic and coronary angiographic variables. The group I L/H ratio of 0.35{+-}0.05 (mean {+-}1 SD) was significantly lower (P<0.001) than the group II L/H ratio of 0.45{+-}0.10. An L/H ratio >0.45 (mean+2 SD in group I) was considered abnormal. In group II, L/H ratio showed a significant correlation with stress and rest {sup 201}Tl perfusion defect size (r=0.39 and r=0.42, P<0.01, respectively), but not with extent of ischaemic myocardium. The mean L/H ratio was 0.41{+-}0.10 in patients with one-vessel disease (n=15), 0.46{+-}0.08 in those with two-vessel disease (n=17) and 0.47{+-}0.12 in those with three-vessel disease (n=12), but no significant difference was found between the three subgroups. L/H ratio showed a significant inverse relation with rest and exercise left ventricular ejection fraction (r=-0.37 and r=-0.50, P<0.05 and P<0.001, respectively). Using stepwise multiple regression analysis, exercise left ventricular ejection fraction and previous history of hypertension were the sole two variables independently predictive of the L/H ratio. In conclusion, although lung thallium uptake is

  18. Evaluation of Various Cardiac Indices and ROC Analysis in Coronary Artery Disease Employing Resting ECG Gated Blood Pool Scan

    International Nuclear Information System (INIS)

    Choi, Chang Woon; Lee, Dong Soo; Kim, Sang Eun; Chung, June Key; Lee, Myung Chul; Park, Young Bae; Seo, Jung Don; Lee, Young Woo; Koh, Chang Soon

    1992-01-01

    Gated blood pool scan is frequently used for evaluating the change in cardiac function in various cardiac diseases. But resting gated blood pool scan using only LVEF as a cardiac index has been consistently shown to have a low sensitivity, which is about 50%, in detecting coronary artery disease. So it is recommended to compare exercise gated blood pool scan to resting gated blood pool scan. Exercise tests, however, are not always possible, especially in patients with musculoskeletal diseases, recent myocardial infarction and in elderly persons. We studied the usefulness of resting gated blood pool scan using multiple indices in evaluating the patients with coronary artery disease. Studied cases were 185 patients with coronary artery disease (angina pectoris 31, myocardial infarction 154) and 25 normals with low likelihood of coronary artery disease. We used 99m Tc-labeled RBC, 740 MBq labeled by in vivo method. The data were evaluated by Micro DELTA computer program. The results were as following: 1) The ejection rates (PER, AER) and filling rates (PFR, AFR) were different in normals and patients with angina pectoris or myocardial infarction. 2) Mean phase angle, ejection rates and filling rates could separate normals from coronary artery disease patients with normal LVEF. 3) Regional ejection fraction was decreased at the site of the infarct in patients with myocardial infarction. 4) Peak filling rate was the most detectable index in evaluation of cardiac function in patients with coronary artery disease. 5) The threshold at 1.5 standard deviation of normal range was considered as the most reliable cut-off value from ROC analysis. These data suggest that the resting gated blood pool scan has an important role in the evaluation of cardiac functional changes using various cardiac indices in patients with coronary artery disease.

  19. Myocardial perfusion tomography with 7-pinhole collimator

    Energy Technology Data Exchange (ETDEWEB)

    Yonekura, Y.; Mukai, T.; Yamamoto, K. (Kyoto Univ. (Japan). Faculty of Medicine)

    1980-12-01

    The clinical efficacy of tomographic presentation of myocardial perfusion imaging with 7-pinhole collimator was evaluated. 35 cases including 5 normals, 4 patients with diffuse left ventricular hypertrophy, 21 with coronary artery disease (CAD) and 5 with hypertrophic cardiomyopathy (HCM) documented by coronary angiography and left ventriculography were selected for this study. Following the conventional /sup 201/Tl myocardial perfusion imaging (MPI), myocardial perfusion tomography (MPT) with 7-pinhole collimator was performed in both LAO and RAO projection. In addition, to examine wall motion abnormalities tomographically, /sup 201/Tl MPI as well as sup(99m)Tc-RBC blood pool imaging were gated to reconstruct multigated MPT (MGMPT) and multigated cardiac pool tomography (MGCPT). The detectability of the defect of the 7-pinhole tomography was compared with that of the conventional image using a cardiac phantom. The same degree of detectability was shown with both these two images. The MPT in LAO projection revealed superior sensitivity to the conventional MPI in the case of inferior wall infarction, and the MPT in RAO projection revealed superior sensitivity in the case of anterior wall infarction. A combination of the MGMPT and MGCPT succeeded in visualizing a subendocardial infarction as a focal gap between these two images. In the case of the small infarction undetectable in the conventional MPI, it can be seen as subtle wall motion abnormalities in the tomographic presentation in movie format. An asymmetrical hypertrophy in HCM can readily be localized in tomographic visualization. Tomographic reconstruction with 7-pinhole collimator from the optimal tomographic plane should be attempted, when the conventional display is equivocal.

  20. Evaluation of diastolic phase by left ventricular volume curve using s2-gated equilibrium method among radioisotope angiography

    International Nuclear Information System (INIS)

    Watanabe, Yoshirou; Sakai, Akira; Inada, Mitsuo; Shiraishi, Tomokuni; Kobayashi, Akitoshi

    1982-01-01

    S2-gated (the second heart sound) method was designed by authors. In 6 normal subjects and 16 patients (old myocardial infarction 12 cases, hypertension 2 cases and aortic regurgitation 2 cases), radioisotope (RI) angiography using S2-gated equilibrium method was performed. In RI angiography, sup(99m)Tc-human serum albumin (HSA) 555MBq (15mCi) as tracer, PDP11/34 as minicomputer and PCG/ECG symchromizer (Metro Inst.) were used. Then left ventricular (LV) volume curve by S2-gated and electrocardiogram (ECG) R wave-gated method were obtained. Using LV volume curve, left ventricular ejection fraction (EF), mean ejection rate (mER, s -1 ), mean filling rate (mFR, -1 ) and rapid filling fraction (RFF) were calculated. mFR indicated mean filling rate during rapid filling phase. RFF was defined as the filling fraction during rapid filling phase among stroke volume. S2-gated method was reliable in evaluation of early diastolic phase, compared with ECG-gated method. There was the difference between RFF in normal group and myocardial infarction (MI) group (p < 0.005). RFF in 2 groups were correlated with EF (r = 0.82, p < 0.01). RFF was useful in evaluating MI cases who had normal EF values. The comparison with mER by ECG-gated and mFR by S2-gated was useful in evaluating MI cases who had normal mER values. mFR was remarkably lower than mER in MI group, but was equal to mER in normal group approximately. In conclusion, the evaluation using RFF and mFR by S2-gated method was useful in MI cases who had normal systolic phase indices. (author)

  1. Analysis of the cardiac motion in myocardial infarction by the ECG-synchronized CT

    International Nuclear Information System (INIS)

    Watanabe, Shigeru; Shimizu, Masahiko; Yoshida, Hideo; Morooka, Nobuhiro; Shukuya, Masaki

    1981-01-01

    The cardiac motion in patients with myocardial infarction was analyzed by the ECG-synchronized computed tomography (CT). For ECG synchronization, the ECG gating method and the data sorting method were used. By the ECG gating method, the gated cardiac images during 0.1 msec intervals at end-diastolic and the end-systolic phases were obtained. By the data sorting method, phasic CT images were reconstructed retrospectively by selecting appropriate data from a series of consecutive scans taken with simultaneous continuous ECG recordings. Six normal subjects and eight patients with myocardial infarction were studied by the ECG gating method, and 14 normal subjects and 25 patients with myocardial infarction were studied by the data sorting method. The end-diastolic and the end-systolic pictures at mid left ventricular level were superimposed and the cardiac borders were traced for the analysis (Fig. 4). Then the cardiac cross-sectional areas at each cardiac phase (40 msec) were calculated, and a cardiac area curve was obtained by plotting them consecutively. The cross-sectional images were divided into right anterior, right posterior, left anterior and left posterior segments. Cardiac area curves of the each segment were also obtained for further analysis. From these curves, the changing ratio of cardiac areas (maximum area - minimum area/maximum area) and the maximum area velocity in systole and diastole were calculated. On the images and the cardiac area curves in myocardial infarction patients, abnormal myocardial movements such as partial akinesis, hypokinesis or paradoxical movement were apparent asd the area of abnormal motions corresponded well with the location of infarction determined by ECG, RI scanning and angiography. A decrease of the changing ratio and the velocity in the infarction area were shown (Fig. 6, 7) and the functional disturbances were suggested during not only systole but diastole also. (author)

  2. Functional imaging in the assessment of myocardial infarction: MR imaging vs. MDCT vs. SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Mahnken, Andreas H. [Department of Diagnostic Radiology, RWTH Aachen University (Germany); Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University (Germany)], E-mail: mahnken@rad.rwth-aachen.de; Bruners, Philipp [Department of Diagnostic Radiology, RWTH Aachen University (Germany); Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University (Germany); Stanzel, Sven [Institute of Medical Statistics, RWTH Aachen University (Germany); Koos, Ralf [Medical Clinic I, RWTH Aachen University (Germany); Muehlenbruch, Georg; Guenther, Rolf W. [Department of Diagnostic Radiology, RWTH Aachen University (Germany); Reinartz, Patrick [Department of Nuclear Medicine, RWTH Aachen University (Germany); Radios Center of Diagnostic Radiology and Nuclear Medicine, Duesseldorf (Germany)

    2009-09-15

    Purpose: To intraindividually compare magnetic resonance (MR) imaging, ECG-gated multi-detector spiral computed tomography (MDCT) and gated single photon emission computed tomography (SPECT) for the evaluation of global and regional myocardial function and the identification of myocardial perfusion abnormalities. Materials and methods: Nine patients (8 men; 55.1 {+-} 8.9 years) with a history of myocardial infarction (MI) were included in this retrospective study. All patients had undergone segmented k-space steady state free precession MR imaging, {sup 99m}Tc-MIBI gated myocardial perfusion SPECT and contrast enhanced ECG-gated 16-MDCT. Ventricular volumes and ejection fraction (EF) were calculated. Left ventricular (LV) wall motion at rest was analyzed. For SPECT and arterial phase MDCT perfusion abnormalities were assessed. Data was compared with Lin's concordance-correlation coefficient ({rho}{sub c}), Bland-Altman plots and kappa statistics. Results: For EF, there was an excellent concordance and correlation ({rho}{sub c} = 0.99) between SPECT (EF = 41.7 {+-} 10.4%), MDCT (EF = 42.2 {+-} 11.1%), and MR imaging (EF = 41.9 {+-} 11.4%). Considering MR imaging as standard of reference, MDCT ({kappa} = 0.86) is superior to SPECT ({kappa} = 0.51) for the assessment of the regional wall motion at rest. There was a good agreement between SPECT and MDCT regarding the detection of perfusion abnormalities ({kappa} = 0.62). Conclusion: MDCT, MR imaging, and SPECT allow for the reliable assessment of global and regional left ventricular function in patients with a history of MI. MDCT also allows to some extent for the detection of perfusion abnormalities. With its potential to assess both, the coronary arteries as well as the myocardium, MDCT a promising modality for the comprehensive diagnostic work-up in patients with suspected myocardial ischemia.

  3. Ultrafast, high precision gated integrator

    Energy Technology Data Exchange (ETDEWEB)

    Wang, X.

    1995-01-01

    An ultrafast, high precision gated integrator has been developed by introducing new design approaches that overcome the problems associated with earlier gated integrator circuits. The very high speed is evidenced by the output settling time of less than 50 ns and 20 MHz input pulse rate. The very high precision is demonstrated by the total output offset error of less than 0.2mV and the output droop rate of less than 10{mu}V/{mu}s. This paper describes the theory of this new gated integrator circuit operation. The completed circuit test results are presented.

  4. Influence of arm positioning on tomographic thallium-201 myocardial perfusion imaging and the effect of attenuation correction

    International Nuclear Information System (INIS)

    Prvulovich, E.M.; Jarritt, P.H.; Vorontsova, E.; Bomanji, J.B.; Ell, P.J.

    2000-01-01

    Lateral attenuation in single-photon emission tomography (SPET) myocardial perfusion imaging (MPI) has been attributed to the left arm if it is held by the patient's side during data acquisition. As a result MPI data are conventionally acquired with the arms held above the head. The aims of this study were to determine the effect of imaging arms down on reconstructed tomographic images depicting regional myocardial thallium-201 distribution and to assess whether attenuation-corrected (AC) myocardial perfusion images acquired arms down could replace uncorrected (NC) images acquired arms up for routine clinical service. Twenty-eight patients referred for routine MPI underwent sequential 180 emission/transmission imaging for attenuation correction using an L-shaped dual-headed gamma camera (GE Optima) fitted with two gadolinium-153 scanning line sources. Delay data were acquired twice: once supine with the arms up and then supine with the arms down. Detector radius of rotation (ROR) for arms up and arms-down studies was recorded. For each data set, count density was measured in 17 segments of a polar plot and segmental uptake expressed relative to study maximum. Oblique images were assessed qualitatively by two observers blinded to study type for tracer distribution and overall quality. Transmission maps were assessed for truncation. Mean detector ROR was 190 mm for arms-up studies and 232 mm for arms-down studies (P 201 Tl distribution, particularly anterolaterally. There is lateral undercorrection in approximately 10% of AC arms-down studies, possibly because of attenuation map truncation. Image quality is reduced in about one-third of AC arms-down studies compared with NC arms-up studies. These data suggest that this attenuation correction method is not sufficiently robust to allow routine acquisition of MPI data with the arms down. (orig.)

  5. Scintigraphy for the detection of myocardial damage in the indeterminate form of Chagas disease

    Energy Technology Data Exchange (ETDEWEB)

    Pedroso, Enio Roberto Pietra; Rezende, Nilton Alves de, E-mail: narezende@terra.com.b [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Faculdade de Medicina; Abuhid, Ivana Moura [Instituto de Medicina Nuclear e Diagnostico Molecular, Belo Horizonte, MG (Brazil)

    2010-07-15

    Background: non-invasive cardiological methods have been used for the identification of myocardial damage in Chagas disease. Objective: to verify whether the rest/stress myocardial perfusion scintigraphy is able to identify early myocardial damage in the indeterminate form of Chagas disease. Methods: eighteen patients with the indeterminate form of Chagas Disease and the same number of normal controls, paired by sex and age, underwent rest/stress myocardial scintigraphy using sestamibi-99mTc, aiming at detecting early cardiac damage. Results: the results did not show perfusion or ventricular function defects in patients at the indeterminate phase of Chagas disease and in the normal controls, except for a patient who presented signs of ventricular dysfunction in the myocardial perfusion scintigraphy with electrocardiographic gating. Conclusion: the results of this study, considering the small sample size, showed that the rest/stress myocardial scintigraphy using sestamibi-99mTc is not an effective method to detect early myocardial alterations in the indeterminate form of Chagas disease (author)

  6. 49 CFR 234.223 - Gate arm.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Gate arm. 234.223 Section 234.223 Transportation... Maintenance Standards § 234.223 Gate arm. Each gate arm, when in the downward position, shall extend across... clearly viewed by approaching highway users. Each gate arm shall start its downward motion not less than...

  7. Demonstration of a Quantum Nondemolition Sum Gate

    DEFF Research Database (Denmark)

    Yoshikawa, J.; Miwa, Y.; Huck, Alexander

    2008-01-01

    The sum gate is the canonical two-mode gate for universal quantum computation based on continuous quantum variables. It represents the natural analogue to a qubit C-NOT gate. In addition, the continuous-variable gate describes a quantum nondemolition (QND) interaction between the quadrature...

  8. Reversible logic gates on Physarum Polycephalum

    International Nuclear Information System (INIS)

    Schumann, Andrew

    2015-01-01

    In this paper, we consider possibilities how to implement asynchronous sequential logic gates and quantum-style reversible logic gates on Physarum polycephalum motions. We show that in asynchronous sequential logic gates we can erase information because of uncertainty in the direction of plasmodium propagation. Therefore quantum-style reversible logic gates are more preferable for designing logic circuits on Physarum polycephalum

  9. Diagnosis of accessory conduction pathway using ECG-gated emission CT analysis

    International Nuclear Information System (INIS)

    Misaki, Takuro; Mukai, Keiichi; Tsubota, Makoto; Iwa, Takashi; Nakajima, Ken-ichi; Hisada, Kin-ichi

    1987-01-01

    Pinpointing the location of accessory conduction pathway (ACP) is of great importance in the surgical treatment for Wolff-Parkinson-White (WPW) syndrome. For this purpose, this study explored the usefulness of ECG-gated emission computed tomography (Gated-ECT) in 30 patients who preoperatively underwent Gated-ECT. The site of earliest contraction at level of atrioventicular valves, obtained on tomographic phase analysis, was compared with the site of earliest activation, obtained on epicardial mapping during surgery. The concordance rate of the two methods was 94 % (28/30). Among them, one patient was found to have the association of corrected transposition of great arteries on Gated-ECT. Gated-ECT was, however, of limited value in differentiating right posterior ACP from right postseptal ACP. The discordance between the sites of earliest contraction and activation, which was observed in the two others, was likely due to decreased wall motion resulting from myocardial disturbance. Gated-ECT may have a diagnostic potential for the location of ACP, especially in view of providing images that corresponded to the surgical anatomy. (Namekawa, K.)

  10. A comparison of maximal exercise and dipyridamole thallium-201 planar gated scintigraphy

    International Nuclear Information System (INIS)

    Martin, W.; Tweddel, A.C.; Main, G.; Hutton, I.

    1992-01-01

    Both symptom-limited maximal exercise and intravenously given dipyridamole stress (0.56 mg/kg over 4 min with a 2 min walk) gated thallium scans were performed in 22 patients undergoing coronary arteriography for the assessment of chest pain. All scans were acquired gated to the electrocardiogram in 3 projections and were reported for the presence and extent of defects in 5 myocardial segments in each view. In addition, left and right ventricular myocardial uptake and estimates of right and left lung and liver to left ventricular uptake were assessed relative to the injected dose of thallium-201. Overall, 190/310 segments were abnormal with exercise compared with 169/310 with dipyridamole. Segments were scored greater in extent in 90/310 cases with exercise, compared with 46/310 in which the defect was more extensive with dipyridamole. Non-attenuation corrected percentage myocardial thallium uptakes were similar for both stresses. Left and right lung and liver to left ventricle ratios were all significantly higher with dipyridamole than with exercise. High right and left lung uptakes with dipyridamole were strongly correlated with high exercise values. The liver uptake was weakly correlated between the 2 different stress tests. These results demonstrate that dipyridamole induces fewer and less extensive thallium perfusion defects than maximal exercise, and that liver and lung to myocardial ratios are higher with dipyridamole than with exercise. (orig./MG)

  11. Right putamen and age are the most discriminant features to diagnose Parkinson's disease by using 123I-FP-CIT brain SPET data by using an artificial neural network classifier, a classification tree (ClT).

    Science.gov (United States)

    Cascianelli, S; Tranfaglia, C; Fravolini, M L; Bianconi, F; Minestrini, M; Nuvoli, S; Tambasco, N; Dottorini, M E; Palumbo, B

    2017-01-01

    The differential diagnosis of Parkinson's disease (PD) and other conditions, such as essential tremor and drug-induced parkinsonian syndrome or normal aging brain, represents a diagnostic challenge. 123 I-FP-CIT brain SPET is able to contribute to the differential diagnosis. Semiquantitative analysis of radiopharmaceutical uptake in basal ganglia (caudate nuclei and putamina) is very useful to support the diagnostic process. An artificial neural network classifier using 123 I-FP-CIT brain SPET data, a classification tree (CIT), was applied. CIT is an automatic classifier composed of a set of logical rules, organized as a decision tree to produce an optimised threshold based classification of data to provide discriminative cut-off values. We applied a CIT to 123 I-FP-CIT brain SPET semiquantitave data, to obtain cut-off values of radiopharmaceutical uptake ratios in caudate nuclei and putamina with the aim to diagnose PD versus other conditions. We retrospectively investigated 187 patients undergoing 123 I-FP-CIT brain SPET (Millenium VG, G.E.M.S.) with semiquantitative analysis performed with Basal Ganglia (BasGan) V2 software according to EANM guidelines; among them 113 resulted affected by PD (PD group) and 74 (N group) by other non parkinsonian conditions, such as Essential Tremor and drug-induced PD. PD group included 113 subjects (60M and 53F of age: 60-81yrs) having Hoehn and Yahr score (HY): 0.5-1.5; Unified Parkinson Disease Rating Scale (UPDRS) score: 6-38; N group included 74 subjects (36M and 38 F range of age 60-80 yrs). All subjects were clinically followed for at least 6-18 months to confirm the diagnosis. To examinate data obtained by using CIT, for each of the 1,000 experiments carried out, 10% of patients were randomly selected as the CIT training set, while the remaining 90% validated the trained CIT, and the percentage of the validation data correctly classified in the two groups of patients was computed. The expected performance of an "average

  12. Bill Gates vil redde Folkeskolen

    DEFF Research Database (Denmark)

    Fejerskov, Adam Moe

    2014-01-01

    Det amerikanske uddannelsessystem bliver for tiden udsat for hård kritik, ledt an af Microsoft stifteren Bill Gates. Gates har indtil videre brugt 3 mia. kroner på at skabe opbakning til tiltag som præstationslønning af lærere og strømlining af pensum på tværs af alle skoler i landet...

  13. Latest design of gate valves

    Energy Technology Data Exchange (ETDEWEB)

    Kurzhofer, U.; Stolte, J.; Weyand, M.

    1996-12-01

    Babcock Sempell, one of the most important valve manufacturers in Europe, has delivered valves for the nuclear power industry since the beginning of the peaceful application of nuclear power in the 1960s. The latest innovation by Babcock Sempell is a gate valve that meets all recent technical requirements of the nuclear power technology. At the moment in the United States, Germany, Sweden, and many other countries, motor-operated gate and globe valves are judged very critically. Besides the absolute control of the so-called {open_quotes}trip failure,{close_quotes} the integrity of all valve parts submitted to operational forces must be maintained. In case of failure of the limit and torque switches, all valve designs have been tested with respect to the quality of guidance of the gate. The guidances (i.e., guides) shall avoid a tilting of the gate during the closing procedure. The gate valve newly designed by Babcock Sempell fulfills all these characteristic criteria. In addition, the valve has cobalt-free seat hardfacing, the suitability of which has been proven by friction tests as well as full-scale blowdown tests at the GAP of Siemens in Karlstein, West Germany. Babcock Sempell was to deliver more than 30 gate valves of this type for 5 Swedish nuclear power stations by autumn 1995. In the presentation, the author will report on the testing performed, qualifications, and sizing criteria which led to the new technical design.

  14. Myocardial metabolism of 123I-BMIPP during low-flow ischaemia in an experimental model: comparison with myocardial blood flow and 18F-FDG

    International Nuclear Information System (INIS)

    Hosokawa, Ryohei; Nohara, Ryuji; Hirai, Taku; Fujita, Masatoshi; Sasayama, Shigetake; Fujibayashi, Yasuhisa; Magata, Yasuhiro; Tadamura, Eiji; Konishi, Junji

    2001-01-01

    Risk stratification of coronary artery disease may provide a basis for selection of treatment to prevent myocardial events and to assist functional recovery. Iodine-123 (ρ-iodophenyl)-3-R,S-methylpentadecanoic acid ( 123 I-BMIPP) is a radioiodinated fatty acid analogue for single-photon emission tomographic (SPET) imaging, and several reports have demonstrated that the abnormal uptake of 123 I-BMIPP is associated with wall motion abnormality and severe coronary artery stenosis. Clarification of the contribution of fatty acids to myocardial metabolism would be highly valuable in recognising this critical condition. In this study, we investigated the myocardial uptake of 123 I-BMIPP under low-flow ischaemia, and compared it with the uptake of fluorine-18 fluorodeoxyglucose ( 18 F-FDG). Using open chest dogs, the flow of the left anterior descending coronary artery was controlled using a pneumatic occluder in order to maintain a 30%-40% reduction of Doppler flow. 123 I-BMIPP and 18 F-FDG were injected into the left atrium after 90 min of ischaemia (protocols 1 and 3). Canine hearts were excised after 120 min of ischaemia for the measurement of radioactivity. In protocol 2, 123 I-BMIPP alone was injected and hearts were excised 8 min after the injection. A time-course biopsy study was also performed at the same time (protocol 3). Wall thickening was evaluated using a wall tracker module. The uptake of 18 F-FDG increased significantly in the ischaemic region (232%±135% vs non-ischaemic, P 18 F-FDG did not correlate well with the severity of MBF. On the other hand, 123 I-BMIPP uptake decreased gradually (78.9%±23.6%, P 123 I-BMIPP was associated not only with wall motion abnormality but also with the severity of MBF. In the biopsy study (protocol 3), the radioactivity of either 123 I-BMIPP or 18 F-FDG correlated well with the MBF at the time of tracer injection and was similar to post-mortem analysis. It is concluded that 18 F-FDG is a valid tool for identifying

  15. MR imaging distinction between occlusive and reperfused myocardial infarctions with a myocardial persistent contrast medium

    International Nuclear Information System (INIS)

    Saeed, M.; Wagner, S.; Wendland, M.; Derugin, N.; Pomeroy, O.; Higgins, C.B.

    1988-01-01

    Paramagnetic contrast agents have limitations for myocardial enhancement of the area at risk after acute occlusion and for differentiating occlusive and reperfused infarctions. A new contrast medium was used in an attempt to discriminate occlusive and reperfused infarctions. The pattern of enhancement was compared in occlusive (6-hour occlusion, 13 rats) and reperfused (2-hour occlusion and 4-hour reperfusion, ten rats) infarctions with electrocardiogram-gated MR imaging. MR imaging of infarcted areas was histologically and histochemically documented. Rats received 100-mM Mn-DPDP. The reperfused infarct showed transmural enhancement early after Mn-DPDP administration. However, occlusive infarcts showed no early enhancement. The difference in the pattern was significant. Mn-DPDP has the potential to distinguish between the occlusive and reperfused infarctions

  16. Thallium myocardial tomoscintigraphy: detection of ischemia during weaning from mechanical ventilation in patients with chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Andre, L.; Valette, H.; Obama, S.; Archambaud, F.; Richard, C.; Teboul, J.L.; Hebert, J.L.; Auzepy, P.; Desgrez, A.

    1990-01-01

    In order to evidence myocardial ischemia-leading to ventricular dysfunction-during weaning from mechanical ventilation in patients with chronic obstructive pulmonary disease, thallium myocardial tomography and gated blood pool studies were performed in 9 patients during mechanical ventilation and during weaning from mechanical ventilation. During the latter, results of gated blood pool studies showed a diffuse homogeneous left ventricular dysfunction. A fixed lower thallium uptake in the septum than in the lateral wall was found with the quantitative analysis of myocardial tomograms. Partial volume effect is likely the cause of this septal defect. The hypothesis of a diffuse ischemia cannot be excluded; but, without the absolute quantification of tomographic data, it cannot be proven [fr

  17. Sepsis and myocardial dysfunction

    Directory of Open Access Journals (Sweden)

    Rafaela Deczka Morsch

    2006-12-01

    Full Text Available Sepsis and septic shock are prevalent in the intensive care setting,accounting for more than 40% of mortality in this scenario. Theappropriate management and recognition of sepsis-inducedmyocardial dysfunction are paramount for its proper treatmentand probably impact mortality rates. The objective of this articleis to review its definition, pathophysiologic mechanisms, possibletreatments and current research on the subject according to acritical view.Cellular signaling involved in myocardial depression is not fullyunderstood. Disturbances in calcium homeostasis,cardiodepressant circulating factors, inflammatory mediators,nitric oxide and apoptosis act as synergistic pathways that leadto severely depressed cardiac function. The diagnosis ofmyocardial dysfunction during sepsis carries a worse prognosisand increased mortality.Myocardial dysfunction plays an important role in morbidity andmortality rate of critically ill patients. Current research in thisarea will continue to evolve; we will, therefore, soon have moreinsights into potential novel therapies that can change its mortalityrates.

  18. [Bonsai induced acute myocardial infarction].

    Science.gov (United States)

    Ayhan, Hüseyin; Aslan, Abdullah Nabi; Süygün, Hakan; Durmaz, Tahir

    2014-09-01

    Incidences of drug abuse and cannabis have increased in young adults, recently. Cannabis induced myocardial infarction has rarely been reported in these people. There is no any literature about a synthetic cannabinoid, being recently most popular Bonsai, to cause myocardial infarction. In this case report we presented a 33-year-old male patient who developed acute myocardial infarction after taking high doses of Bonsai.

  19. Sensory gating in primary insomnia.

    Science.gov (United States)

    Hairston, Ilana S; Talbot, Lisa S; Eidelman, Polina; Gruber, June; Harvey, Allison G

    2010-06-01

    Although previous research indicates that sleep architecture is largely intact in primary insomnia (PI), the spectral content of the sleeping electroencephalographic trace and measures of brain metabolism suggest that individuals with PI are physiologically more aroused than good sleepers. Such observations imply that individuals with PI may not experience the full deactivation of sensory and cognitive processing, resulting in reduced filtering of external sensory information during sleep. To test this hypothesis, gating of sensory information during sleep was tested in participants with primary insomnia (n = 18) and good sleepers (n = 20). Sensory gating was operationally defined as (i) the difference in magnitude of evoked response potentials elicited by pairs of clicks presented during Wake and Stage II sleep, and (ii) the number of K complexes evoked by the same auditory stimulus. During wake the groups did not differ in magnitude of sensory gating. During sleep, sensory gating of the N350 component was attenuated and completely diminished in participants with insomnia. P450, which occurred only during sleep, was strongly gated in good sleepers, and less so in participants with insomnia. Additionally, participants with insomnia showed no stimulus-related increase in K complexes. Thus, PI is potentially associated with impaired capacity to filter out external sensory information, especially during sleep. The potential of using stimulus-evoked K complexes as a biomarker for primary insomnia is discussed.

  20. New opening hours of the gates

    CERN Multimedia

    GS Department

    2009-01-01

    Please note the new opening hours of the gates as well as the intersites tunnel from the 19 May 2009: GATE A 7h - 19h GATE B 24h/24 GATE C 7h - 9h\t17h - 19h GATE D 8h - 12h\t13h - 16h GATE E 7h - 9h\t17h - 19h Prévessin 24h/24 The intersites tunnel will be opened from 7h30 to 18h non stop. GS-SEM Group Infrastructure and General Services Department

  1. Respiratory gating in cardiac PET

    DEFF Research Database (Denmark)

    Lassen, Martin Lyngby; Rasmussen, Thomas; Christensen, Thomas E

    2017-01-01

    BACKGROUND: Respiratory motion due to breathing during cardiac positron emission tomography (PET) results in spatial blurring and erroneous tracer quantification. Respiratory gating might represent a solution by dividing the PET coincidence dataset into smaller respiratory phase subsets. The aim...... stress (82)RB-PET. Respiratory rates and depths were measured by a respiratory gating system in addition to registering actual respiratory rates. Patients undergoing adenosine stress showed a decrease in measured respiratory rate from initial to later scan phase measurements [12.4 (±5.7) vs 5.6 (±4.......7) min(-1), P PET...

  2. Myocardial perfusion modeling using MRI

    DEFF Research Database (Denmark)

    Larsson, H B; Fritz-Hansen, T; Rostrup, Egill

    1996-01-01

    In the present study, it is shown that it is possible to quantify myocardial perfusion using magnetic resonance imaging in combination with gadolinium diethylenetriaminopentaacetic acid (Gd-DTPA). Previously, a simple model and method for measuring myocardial perfusion using an inversion recovery...

  3. Assessment of myocardial viability.

    Science.gov (United States)

    Travin, Mark I; Bergmann, Steven R

    2005-01-01

    The prevalence of left ventricular (LV) dysfunction and resultant congestive heart failure is increasing. Patients with this condition are at high risk for cardiac death and usually have significant limitations in their lifestyles. Although there have been advances in medical therapy resulting in improved survival and well being, the best and most definitive therapy, when appropriate, is revascularization. In the setting of coronary artery disease, accounting for approximately two thirds of cases of congestive heart failure, LV dysfunction often is not the result of irreversible scar but rather caused by impairment in function and energy use of still viable-myocytes, with the opportunity for improved function if coronary blood flow is restored. Patients with LV dysfunction who have viable myocardium are the patients at highest risk because of the potential for ischemia but at the same time benefit most from revascularization. It is important to identify viable myocardium in these patients, and radionuclide myocardial scintigraphy is an excellent tool for this. Single-photon emission computed tomography perfusion scintigraphy, whether using thallium-201, Tc-99m sestamibi, or Tc-99m tetrofosmin, in stress and/or rest protocols, has consistently been shown to be an effective modality for identifying myocardial viability and guiding appropriate management. Metabolic imaging with positron emission tomography radiotracers frequently adds additional information and is a powerful tool for predicting which patients will have an improved outcome from revascularization, including some patients referred instead for cardiac transplantation. Other noninvasive modalities, such as stress echocardiography, also facilitate the assessment of myocardial viability, but there are advantages and disadvantages compared with the nuclear techniques. Nuclear imaging appears to require fewer viable cells for detection, resulting in a higher sensitivity but a lower specificity than stress

  4. Robust logic gates and realistic quantum computation

    International Nuclear Information System (INIS)

    Xiao Li; Jones, Jonathan A.

    2006-01-01

    The composite rotation approach has been used to develop a range of robust quantum logic gates, including single qubit gates and two qubit gates, which are resistant to systematic errors in their implementation. Single qubit gates based on the BB1 family of composite rotations have been experimentally demonstrated in a variety of systems, but little study has been made of their application in extended computations, and there has been no experimental study of the corresponding robust two qubit gates to date. Here we describe an application of robust gates to nuclear magnetic resonance studies of approximate quantum counting. We find that the BB1 family of robust gates is indeed useful, but that the related NB1, PB1, B4, and P4 families of tailored logic gates are less useful than initially expected

  5. Gating Technology for Vertically Parted Green Sand Moulds

    DEFF Research Database (Denmark)

    Larsen, Per

    Gating technology for vertically parted green sand moulds. Literature study of different ways of designing gating systems.......Gating technology for vertically parted green sand moulds. Literature study of different ways of designing gating systems....

  6. A decision support system improves the interpretation of myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Taegil, K.; Bondouy, M.; Chaborel, J.P.; Franken, P.R.; Djaballah, W.; Grandpierre, S.; Marie, P.Y.; Poisson, T.; Hesse, B.; Lomsky, M.; Edenbrandt, L.

    2008-01-01

    The aim of this study was to investigate the influence of a computer-based decision support system (DSS) on performance and inter-observer variability of interpretations regarding ischaemia and infarction in myocardial perfusion scintigraphy (MPS). Seven physicians independently interpreted 97 MPS studies, first without and then with the advice of a DSS. Four physicians had long experience and three had limited experience in the interpretation of MPS. Each study was interpreted regarding myocardial ischaemia and infarction in five myocardial regions. The patients had undergone a gated MPS using a 2-day stress/gated rest 99m Tc sestamibi protocol. The gold standard used was the interpretations made by one experienced nuclear medicine specialist on the basis of all available clinical and image information. The sensitivity for ischaemia of the seven readers increased from 81% without the DSS to 86% with the DSS (p 0.01). The increase in sensitivity was higher for the three inexperienced physicians (9%) than for the four experienced physicians (2%). There was no significant change in specificity between the interpretations. The interpretations of ischaemia made with the advice of the DSS showed less inter-observer variability than those made without advice. This study shows that a DSS can improve performance and reduces the inter-observer variability of interpretations in myocardial perfusion imaging. Both experienced and, especially, inexperienced physicians can improve their interpretation with the advice from such a system. (orig.)

  7. Dynamic gating window for compensation of baseline shift in respiratory-gated radiation therapy

    International Nuclear Information System (INIS)

    Pepin, Eric W.; Wu Huanmei; Shirato, Hiroki

    2011-01-01

    Purpose: To analyze and evaluate the necessity and use of dynamic gating techniques for compensation of baseline shift during respiratory-gated radiation therapy of lung tumors. Methods: Motion tracking data from 30 lung tumors over 592 treatment fractions were analyzed for baseline shift. The finite state model (FSM) was used to identify the end-of-exhale (EOE) breathing phase throughout each treatment fraction. Using duty cycle as an evaluation metric, several methods of end-of-exhale dynamic gating were compared: An a posteriori ideal gating window, a predictive trend-line-based gating window, and a predictive weighted point-based gating window. These methods were evaluated for each of several gating window types: Superior/inferior (SI) gating, anterior/posterior beam, lateral beam, and 3D gating. Results: In the absence of dynamic gating techniques, SI gating gave a 39.6% duty cycle. The ideal SI gating window yielded a 41.5% duty cycle. The weight-based method of dynamic SI gating yielded a duty cycle of 36.2%. The trend-line-based method yielded a duty cycle of 34.0%. Conclusions: Dynamic gating was not broadly beneficial due to a breakdown of the FSM's ability to identify the EOE phase. When the EOE phase was well defined, dynamic gating showed an improvement over static-window gating.

  8. Bill Gates eyes healthcare market.

    Science.gov (United States)

    Dunbar, C

    1995-02-01

    The entrepreneurial spirit is still top in Bill Gates' mind as he look toward healthcare and other growth industries. Microsoft's CEO has not intention of going the way of other large technology companies that became obsolete before they could compete today.

  9. Respiratory gating of cardiac PET data in list-mode acquisition

    International Nuclear Information System (INIS)

    Livieratos, Lefteris; Rajappan, Kim; Camici, Paolo G.; Stegger, Lars; Schafers, Klaus; Bailey, Dale L.

    2006-01-01

    Respiratory motion has been identified as a source of artefacts in most medical imaging modalities. This paper reports on respiratory gating as a means to eliminate motion-related inaccuracies in PET imaging. Respiratory gating was implemented in list mode with physiological signal recorded every millisecond together with the PET data. Respiration was monitored with an inductive respiration monitor using an elasticised belt around the patient's chest. Simultaneous ECG gating can be maintained independently by encoding ECG trigger signal into the list-mode data. Respiratory gating is performed in an off-line workstation with gating parameters defined retrospectively. The technique was applied on a preliminary set of patient data with C 15 O. Motion was visually observed in the cine displays of the sagittal and coronal views of the reconstructed respiratory gated images. Significant changes in the cranial-caudal position of the heart could be observed. The centroid of the cardiac blood pool showed an excursion of 4.5-16.5 mm (mean 8.5±4.8 mm) in the cranial-caudal direction, with more limited excursion of 1.1-7.0 mm (mean 2.5±2.2 mm) in the horizontal direction and 1.3-3.7 mm (mean 2.4±0.9 mm) in the vertical direction. These preliminary data show that the extent of motion involved in respiration is comparable to myocardial wall thickness, and respiratory gating may be considered in order to reduce this effect in the reconstructed images. (orig.)

  10. Gate induced drain leakage reduction with analysis of gate fringing field effect on high-κ/metal gate CMOS technology

    Science.gov (United States)

    Jang, Esan; Shin, Sunhae; Jung, Jae Won; Rok Kim, Kyung

    2015-06-01

    We suggest the optimum permittivity for a high-κ/metal gate (HKMG) CMOS structure based on the trade-off characteristics between the fringing field induced barrier lowering (FIBL) and gate induced drain leakage (GIDL). By adopting the high-κ gate dielectric, the GIDL from the band-to-band tunneling at the interface of gate and lightly doped drain (LDD) is suppressed with wide tunneling width owing to the enhanced fringing field, while the FIBL effects is degenerated as the previous reports. These two effects from the gate fringing field are studied extensively to manage the leakage current of HKMG for low power applications.

  11. ``Gate-to-gate`` BJT obtained from the double-gate input JFET to reset charge preamplifiers

    Energy Technology Data Exchange (ETDEWEB)

    Fazzi, A. [Politecnico di Milano (Italy). Dipartimento di Ingegneria Nucleare; Rehak, P. [Brookhaven National Laboratory, Upton, NY 11973 (United States)

    1996-08-01

    A novel charge restoration mechanism to reset charge sensitive preamplifiers is presented. The ``gate-to-gate`` Bipolar Junction Transistor transversal to the input JFET with independent top and bottom gates is exploited as a ``reset transistor`` embodied in the preamplifier input device. The p-n junction between the bottom gate and the channel is forward-biased by a proper feedback loop supplying the necessary restoration current to the input node capacitance through the top gate-channel reversed-biased junction. The continuous reset mode is here analysed with reference to the DC stability, the pulse response and the noise behaviour. Experimental results are reported. (orig.).

  12. Relation between exercise-induced ventricular arrhythmias and myocardial perfusion abnormalities in patients with intermediate pretest probability of coronary artery disease

    International Nuclear Information System (INIS)

    Elhendy, A.; Sozzi, F.B.; Van Domburg, R.T.; Bax, J.J.; Roelandt, J.R.T.C.

    2000-01-01

    We studied 302 patients (mean age 54±9 years, 152 men and 150 women) with intermediate pretest probability of CAD (range=0.25- 0.80, mean=0.43±0.20) by upright bicycle exercise stress test in conjunction with technetium-99m single-photon emission tomography (SPET) imaging. Exercise-induced VAs (frequent or complex premature ventricular contractions or ventricular tachycardia) occurred in 65 patients (22%). No significant difference was found between patients with and patient without VAs regarding the pretest probability of CAD (0.45±0.21 vs 0.43±0.20). Patients with exercise-induced VAs had a higher prevalence of perfusion abnormalities (52% vs 26%, P=0.002) and ischaemic electrocardiographic changes (31% vs 16%, P<0.05) compared to patients without VAs. A higher prevalence of perfusion abnormalities in patients with VAs was observed in both men (67% vs 35%, P<0.01) and women (38% vs 16%, P<0.05). However, the positive predictive value of exercise-induced VAs for the presence of myocardial perfusion abnormalities was higher in men than in women (67% vs 38%, P<0.05). The presence of abnormal myocardial perfusion was the only independent predictor of exercise-induced VAs (OR 2.2; 95% CI, 1.2-4.2) by multivariate analysis of clinical and stress test variables. It is concluded that in patients with intermediate pretest probability of CAD, exercise-induced VAs are predictive of a higher prevalence of myocardial perfusion abnormalities in both men and women. However, the positive predictive value of exercise-induced VAs for perfusion abnormalities is higher in men. Because of the underestimation of ischaemia by electrocardiographic changes, exercise-induced VAs should be interpreted as a marker of a higher probability of CAD. (orig./MG) (orig.)

  13. Evaluation of cellular viability by quantitative autoradiographic study of myocardial uptake of a fatty acid analogue in isoproterenol-induced focal rat heart necrosis

    International Nuclear Information System (INIS)

    Humbert, T.; Luu-Duc, C.; Comet, M.; Demenge, P.

    1991-01-01

    Previous studies led us to hypothesize that a fatty acid analogue, 15-p-iodophenyl-β-methyl pentadecanoic acid (IMPPA or BMIPP), which is taken up but not quickly metabolized by heart cells, would be a more suitable tracer of cellular viability that 201 Tl. Biodistribution studies of 1- 14 C-IMPPA in conscious, freely moving rats showed that the concentration ratio of radioactivity in the heart with respect to the blood was about 8 for at least 60 min after intravenous administration, permitting its use as a putative tracer in these conscious, freely moving rats. Thereafter, the myocardial uptake of 14 C-IMPPA was studied in isoproterenol-treated rats (daily treatment for 10 days in order to induce cardiac hypertrophy and necrotic foci) with respect to control ones. Comparison of myocardial localizations by quantitative autoradiography of the uptake of 201 Tl and 14 C-IMPPA with that of triphenyltetrazolium chloride (TTC) staining enabled comparative evaluation of nutritional blood flow, localization and uptake of 14 C-IMPPA and necrotic foci size. Distributions of 14 C-IMPPA and 201 Tl in control rats' hearts were homogenous, like TTC staining. In infarcted hearts, areas of decreased 14 C-IMPPA uptake were nearly the same (100%±5%) as those unstained by TTC. These areas were larger than those showing a decrease in thallium uptake (about 70%±5% of the total scar size). Therefore, IMPPA seems to be a more accurate and sensitive indicator of necrosis localization compared with thallium. It may be a useful agent for assessment of myocardial viability by single photon emission tomography (SPET) imaging. (orig.)

  14. Myocardial viability assessment using nuclear imaging

    International Nuclear Information System (INIS)

    Matsunari, Ichiro; Hisada, Kinichi; Taki, Junichi; Nakajima, Kenichi; Tonami, Norihisa

    2003-01-01

    Myocardial assessment continues to be an issue in patients with coronary artery disease and left ventricular dysfunction. Nuclear imaging has long played an important role in this field. In particular, PET imaging using 18 F-fluorodeoxyglucose is regarded as the metabolic gold standard of tissue viability, which has been supported by a wide clinical experience. Viability assessment using SPECT techniques has gained more wide-spread clinical acceptance than PET, because it is more widely available at lower cost. Moreover, technical advances in SPECT technology such as gated-SPECT further improve the diagnostic accuracy of the test. However, other imaging techniques such as dobutamine echocardiography have recently emerged as competitors to nuclear imaging. It is also important to note that they sometimes may work in a complementary fashion to nuclear imaging, indicating that an appropriate use of these techniques may significantly improve their overall accuracy. In keeping these circumstances in mind, further efforts are necessary to further improve the diagnostic performance of nuclear imaging as a reliable viability test. (author) 107 refs

  15. Property of electrocardiogram gated single photon emission tomography by sup 99m Tc-methoxy isobutyl isonitrile

    Energy Technology Data Exchange (ETDEWEB)

    Imai, Kamon; Nishio, Yukari; Araki, Yasushi; Saito, Satoshi; Ozawa, Yukio; Yasugi, Tadao; Hagiwara, Kazuo; Kamata, Rikisaburo (Nihon Univ., Tokyo (Japan). School of Medicine)

    1992-06-01

    {sup 99m}Tc-methoxy isobutyl isonitrile (MIBI) is a new developed myocardial perfusion imaging agent. Because this compound has higher photon energy than thallium (Tl), electrocardiogram gated single photon emission tomography (SPECT): end-diastolic (ED) and end-systolic (ES) short axis (SA) images could be taken. To investigate property of gated MIBI SPECT, MIBI myocardial scintigraphy, Tl scintigraphy (TMS) and analysis of left ventricular wall motion were performed in 6 patients with myocardial infarction. Left ventricule was divided into 8 segments. Perfusion defect (PD) was scored: '0' (normal), '1' (hypo-perfusion), '2' (defect). Wall motion abnormality (WMA) was also scored: '0' (normo-kinesis), '1' (hypo-kinesis), '2' (a-, dys-kinesis). Severity and extent of PD and WMA were calculated. Severity of WMA was 3.0{+-}2.0 (M{+-}SD), severity of PD was 3.3{+-}1.7 in TMS, 3.7{+-}1.3 in no-gated MIBI, 5.0{+-}0.6 in ES-MIBI, 7.3{+-}2.0 in ED-MIBI. Extent of WMA was 2.3{+-}1.0. Extent of PD was 2.5{+-}1.3 in TMS, 3.0{+-}1.6 in no-gated MIBI, 3.5{+-}0.8 in ES-MIBI, 4.8{+-}1.0 in ED-MIBI. Compared with wall motion abnormality, severity and extent of PD in ED-MIBI was larger. From our data, it is concluded that perfusion defect in ED-MIBI was overestimated significantly. When we evaluate gated MIBI image, we must consider this property. (author).

  16. Depression following myocardial infarction

    DEFF Research Database (Denmark)

    Larsen, Karen Kjær

    2013-01-01

    Myocardial infarction (MI) is a severe life event that is accompanied by an increased risk of depression. Mounting evidence suggests that post-MI depression is associated with adverse outcomes, but the underlying mechanisms of this association remain unclear, and no previous studies have examined...... whether the mental burden of MI is so heavy that it increases the risk of suicide. Although post-MI depression is common and burdensome, the condition remains under-recognised and under-treated. The development of new strategies to improve the quality of care for people with post-MI depression requires...... thorough understanding of the mechanisms that influence the prognosis as well as knowledge of the present care provided. The purpose of this PhD thesis is accordingly subdivided into four specific aims: 1. To estimate the prevalence of depression in people with MI after three months, and to estimate...

  17. Voltage-gated Proton Channels

    Science.gov (United States)

    DeCoursey, Thomas E.

    2014-01-01

    Voltage-gated proton channels, HV1, have vaulted from the realm of the esoteric into the forefront of a central question facing ion channel biophysicists, namely the mechanism by which voltage-dependent gating occurs. This transformation is the result of several factors. Identification of the gene in 2006 revealed that proton channels are homologues of the voltage-sensing domain of most other voltage-gated ion channels. Unique, or at least eccentric, properties of proton channels include dimeric architecture with dual conduction pathways, perfect proton selectivity, a single-channel conductance ~103 smaller than most ion channels, voltage-dependent gating that is strongly modulated by the pH gradient, ΔpH, and potent inhibition by Zn2+ (in many species) but an absence of other potent inhibitors. The recent identification of HV1 in three unicellular marine plankton species has dramatically expanded the phylogenetic family tree. Interest in proton channels in their own right has increased as important physiological roles have been identified in many cells. Proton channels trigger the bioluminescent flash of dinoflagellates, facilitate calcification by coccolithophores, regulate pH-dependent processes in eggs and sperm during fertilization, secrete acid to control the pH of airway fluids, facilitate histamine secretion by basophils, and play a signaling role in facilitating B-cell receptor mediated responses in B lymphocytes. The most elaborate and best-established functions occur in phagocytes, where proton channels optimize the activity of NADPH oxidase, an important producer of reactive oxygen species. Proton efflux mediated by HV1 balances the charge translocated across the membrane by electrons through NADPH oxidase, minimizes changes in cytoplasmic and phagosomal pH, limits osmotic swelling of the phagosome, and provides substrate H+ for the production of H2O2 and HOCl, reactive oxygen species crucial to killing pathogens. PMID:23798303

  18. Gated cardiac imaging: manual calculations and observations of left ventricular ejection fraction

    International Nuclear Information System (INIS)

    Hawkins, T.; Keavey, P.M.

    1984-01-01

    Using gamma camera imaging, the fixed region and moving region methods of calculating left ventricular ejection fraction were studied. Data were obtained from gated blood pool studies on 125 cardiac patients with myocardial infarcts of varying extent and location. Ejection fractions ranged from 10 to 76%. The left anterior oblique angulation for optimal visualisation of the ventricles showed considerable patient variation. The authors conclude that a fixed angulation cannot be recommended and that there is little to justify it. Where the septum is not seen distinctly during setting up, a larger rather than smaller angle is generally advised. (U.K.)

  19. Myocardial perfusion SPECT for assessment of left ventricular function and volume- comparison with echocardiography

    International Nuclear Information System (INIS)

    Cheng Xu; Huang Gang

    2004-01-01

    Objective: The purpose of this study was to evaluate left ventricular volume and function by gated SPECT and comparison of the results with echocardiography. Methods: 65 Consecutive patients (49 male, 16 female; mean age 61+11 years) who underwent both gated 99m Tc-MIBI myocardial perfusion SPECT and echocardiography within a 15 days period were included in the study. Exclusion criteria were any change in clinical status between acquisition of the gated SPECT and echocardiography studies, acute myocardial infarction occurring less than 7 days before study, and surgical procedures occurring within 30 days of the study. The clinical diagnosis of each patient was not considered, as this was not relevant to the purpose of the study. The diagnoses were as follows: coronary artery disease (n=46), hypertensive heart disease (n=8), old myocardial infarction (n=5), myocarditis (n=2), and routine medical examination(n=4). A dose of 740 MBq of 99 Tc m -sestamibi was administered in resting condition. Gated SPECT images were obtained with ADAC Vertex MCD-AC SPECT system. The raw projection images were reconstructed with filtered back-projection (ramp filter), without attenuation correction. The data, including left ventricular ejection fraction (LVEF), end-diastolic volume (EDV), end-systolic volume (ESV) were obtained using AUTOQUANT software (ADAC corporation). The echocardiography study used its standard techniques. Two nuclear medicine physicians processed the raw images respectively to evaluate internal reproducibility of gated SPECT. In order to compare the results of gated SPECT with echocardiography on different left ventricular volumes, all patients were divided into two groups (EDV 90 ml, n=34) based by EDV measurements in echocardiography. Results: The correlation coefficient of LVEF, EDV, ESV between SPECT and echocardiography were 0.77, 0.86 and 0.90 respectively. P 0.07). The reproducibility of gated SPECT was excellent. There were no significant differences in

  20. FDG gamma camera PET equipped with one inch crystal and XCT. Assessment of myocardial viability

    Energy Technology Data Exchange (ETDEWEB)

    Beheshti, M. [Dept. of Nuclear Medicine, Medical Univ., General Hospital of Vienna (Austria); Dept. of Nuclear Medicine and Endocrinology, PET CT Centre, St. Vincent' s Hospital, Linz (Austria); Khorsand, A.; Graf, S. [Dept. of Cardiology, Medical Univ., General Hospital of Vienna (Austria); Dobrozemsky, G. [Dept. of Nuclear Medicine, Medical Univ. of Innsbruck (Austria); Oezer, S.; Kletter, K.; Dudczak, R. [Dept. of Nuclear Medicine, Medical Univ., General Hospital of Vienna (Austria); Pirich, C. [Dept. of Nuclear Medicine und Endocrinology, Paracelsus Private Medical Univ., SALK, Salzburg (Austria)

    2006-07-01

    Metabolic imaging with 2-[fluorine-18]-fluoro-2-deoxy-D-glucose (FDG) is actually considered as the best method to detect and quantitatively assess myocordial tissue viability. The aim of this study was to investigate the accuracy of FDG gamma camera positron emission tomography (GCPET) imaging equipped with one inch NaI crystals in comparison to FDG dedicated PET (dPET) imaging as a ''gold standard'' in phantom and clinical studies. Patients, methods: nineteen patients with coronary artery disease (CAD) underwent both imaging modalities. Phantom and clinical GCPET imaging were performed with a dual-headed, coincidence based gamma camera equipped with 1 inch thick NaI crystals and an X-ray tube (XCT) for attenuation correction (AC), as well as with a dedicated PET scanner with AC. {sup 99m}Tc tetrofosmin single-photon emission tomography (SPET) studies were performed for assessment of myocardial perfusion, with AC. Results: phantom studies showed a significant relation in segmental activity between FDG imaging with AC using GCPET and dPET (r = 0.91, p < 0.001). In clinical studies with AC correlation coefficients of mean segmental FDG uptake and regional defect size were r = 0.87 (p < 0.0001) and r = 0.83 (p < 0.0001), respectively. In regional analysis close agreement was even found in the most attenuated regions of the heart if AC was used in GCPET imaging. The overall agreement for detection of viable myocardium was 81% between FDG-dPET (AC) and FDG-GCPET (AC) and 74% between FDG-dPET (AC) and FDG-GCPET (NC). Conclusions: suggests that the assessment of myocardial metabolism by means of FDG is feasible with a coincidence based gamma camera equipped with 1 inch thick NaI crystal if AC is performed. The results reveal a close concordance and agreement between FDG-dPET (AC) and FDG-GCPET (AC) as compared to FDG-GCPET (NC). (orig.)

  1. Assessment of viability of acute myocardial infarction using MRI and gadolinium DTPA

    International Nuclear Information System (INIS)

    Toyama, Takuji; Nishimura, Tsunehiko; Yamada, Naoaki

    1993-01-01

    To evaluate the myocardial viability using gated MRI and gadolinium-DTPA enhancement, we compared with Tl-201 exercise myocardial scintigraphy (Ex-Tl) and two-dimensional echocardiography (UCG) in 22 patients with acute myocardial infarction (AMI). These patients were divided into three groups. In group A (8 patients), thallium redistribution (RD) was found at infarcted region. In group B (6 patients), RD was not found at infarcted region, but wall motion by UCG was normal or hypokinesis at infarcted region. In group C (8 patients), RD was not found at infarcted region, and wall motion by UCG was akinesis or dyskinesis at infarcted region. MRI was performed at one week, two weeks, one month and three months from the onset of AMI. We evaluated signal intensity (SI), extent of Gd-E and wall thinning at short axial image of T 1 weighted image. Ex-T l was performed at one month after AMI to evaluate presence of RD and extent of perfusion defect on delayed SPECT image. In addition, UCG was performed within one month after AMI to evaluate regional wall motion at infarcted region. In most cases of groups A and B Gd-E>PD was found. Decrease of Gd-E area was found in group A, but early disappearance of Gd-E within three months was not different among three groups. This study indicated that Gd-E>PD and decrease of Gd-E area reflected myocardial viability at infarcted region to some extent, but SI of Gd-E and early disappearance of Gd-E did not reflect myocardial viability. Gd-E was slightly useful for detecting the myocardial viability of acute myocardial infarction. (author)

  2. Validation of the dual-table autoradiographic method to quantify two sequential rCBFs in a single SPET session with N-isopropyl-[123I]p-iodoamphetamine

    International Nuclear Information System (INIS)

    Nishizawa, Sadahiko; Iida, Hidehiro; Tsuchida, Tatsuro; Ito, Harumi; Konishi, Junji; Yonekura, Yoshiharu

    2003-01-01

    We evaluated an autoradiographic (ARG) method to calculate regional cerebral blood flow (rCBF) sequentially before and after an acetazolamide (ACZ) challenge in a single session of single-photon emission tomography (SPET) with two injections of N-isopropyl-[ 123 I]p-iodoamphetamine (IMP). The method uses a table look-up method with a fixed distribution volume (Vd) and a standard input function of IMP. To calculate rCBF after an ACZ challenge, two look-up tables (a dual-table) are used to reflect the effect of radioactivity in the brain from the first dose of IMP. We performed simulation studies to evaluate errors attributable to (a) a change in rCBF induced by an ACZ challenge during the scan and (b) a fixed Vd value that might be different from an individual one, along with the effect of (c) scan length. Thirty-three patients were studied by dynamic SPET with two injections of IMP and frequent arterial blood sampling, and the data were analysed using the dual-table ARG method. Twenty-four of the 33 patients received an injection of ACZ 10 min before the second dose of IMP. We generated a standard input function by averaging individual input functions. The optimal method to calibrate a standard input function was determined so that the SD of differences between rCBF calculated by using a calibrated standard input function (F SIF ) and that calculated by using an individual input function (F IIF ) was minimised. Reliability of the method was evaluated by comparing F SIF with gold standard rCBF (F REF ) obtained by two-compartment model analysis of dynamic SPET data and an individual input function with a non-linear least squares fitting method. Errors caused by (a) were less than 4% for a first rCBF ranging between 20 and 60 ml 100 g -1 min -1 and an rCBF change of between -25% and 50%. Errors caused by (b) were relatively large compared with those caused by (a), and were affected by (c) with an increasing error in a longer scan. In the patient study with a proposed

  3. Cognitive mechanisms associated with auditory sensory gating

    Science.gov (United States)

    Jones, L.A.; Hills, P.J.; Dick, K.M.; Jones, S.P.; Bright, P.

    2016-01-01

    Sensory gating is a neurophysiological measure of inhibition that is characterised by a reduction in the P50 event-related potential to a repeated identical stimulus. The objective of this work was to determine the cognitive mechanisms that relate to the neurological phenomenon of auditory sensory gating. Sixty participants underwent a battery of 10 cognitive tasks, including qualitatively different measures of attentional inhibition, working memory, and fluid intelligence. Participants additionally completed a paired-stimulus paradigm as a measure of auditory sensory gating. A correlational analysis revealed that several tasks correlated significantly with sensory gating. However once fluid intelligence and working memory were accounted for, only a measure of latent inhibition and accuracy scores on the continuous performance task showed significant sensitivity to sensory gating. We conclude that sensory gating reflects the identification of goal-irrelevant information at the encoding (input) stage and the subsequent ability to selectively attend to goal-relevant information based on that previous identification. PMID:26716891

  4. Myocardial scintigraphy in the diagnosis of myocardial contusion

    Energy Technology Data Exchange (ETDEWEB)

    Terashima, Masayoshi; Shinoda, Mitsutaka; Iwama, Hiroshi; Hirama, Hisao; Hoshino, Toshiaki; Urabe, Shinpei [Central Aizu General Hospital, Fukushima (Japan); Meguro, Taiichiroh

    1996-04-01

    To assess the clinical value of a new fatty acid imaging tracer, {sup 123}I-{beta}-methyl iodophenyl pentadecanoic acid (BMIPP), I-BMIPP and thallium-201 (Tl) dual imaging was performed at rest in fifteen patients with mild blunt chest trauma (mean AIS thoracic 1.4{+-}0.51, mean ISS 6.47{+-}3.50, mean RTS 7.69{+-}0.43). All patients were prospectively evaluated on the basis of serial electrocardiograms (ECG) and cardiac enzyme studies (total CPK). Tl and BMIPP dual scintigrams were performed within 10 days following admission. SPECT images were divided into seven segments, and the segmental images were visually scored according to tracer uptake on a 3 (severely decreased tracer uptake) to 0 (normal) scale. Nine patients had scintigraphic defects and were considered to have a myocardial contusion. ECG findings, AIS, ISS, and CPK levels failed to distinguish between scintigraphically positive patients and scintigraphically negative patients. Five of the 14 hypoperfused segments on BMIPP imaging, showed normal Tl uptake, one showed lower BMIPP uptake than Tl, and the remaining eight showed similar distribution of both tracers. The mismatch between tracer uptake on BMIPP images and Tl images was thought to reflect impaired myocardial fatty acid metabolism. Thus, mild blunt chest trauma results in a higher frequency of traumatic myocardial injury than previously recognized, and BMIPP is a promising radio-pharmaceutical for evaluating impaired myocardial fatty acid metabolism in patients with myocardial contusion. (author).

  5. MCP gated x-ray framing camera

    Science.gov (United States)

    Cai, Houzhi; Liu, Jinyuan; Niu, Lihong; Liao, Hua; Zhou, Junlan

    2009-11-01

    A four-frame gated microchannel plate (MCP) camera is described in this article. Each frame photocathode coated with gold on the MCP is part of a transmission line with open circuit end driven by the gating electrical pulse. The gating pulse is 230 ps in width and 2.5 kV in amplitude. The camera is tested by illuminating its photocathode with ultraviolet laser pulses, 266 nm in wavelength, which shows exposure time as short as 80 ps.

  6. Gating-ML: XML-based gating descriptions in flow cytometry.

    Science.gov (United States)

    Spidlen, Josef; Leif, Robert C; Moore, Wayne; Roederer, Mario; Brinkman, Ryan R

    2008-12-01

    The lack of software interoperability with respect to gating due to lack of a standardized mechanism for data exchange has traditionally been a bottleneck, preventing reproducibility of flow cytometry (FCM) data analysis and the usage of multiple analytical tools. To facilitate interoperability among FCM data analysis tools, members of the International Society for the Advancement of Cytometry (ISAC) Data Standards Task Force (DSTF) have developed an XML-based mechanism to formally describe gates (Gating-ML). Gating-ML, an open specification for encoding gating, data transformations and compensation, has been adopted by the ISAC DSTF as a Candidate Recommendation. Gating-ML can facilitate exchange of gating descriptions the same way that FCS facilitated for exchange of raw FCM data. Its adoption will open new collaborative opportunities as well as possibilities for advanced analyses and methods development. The ISAC DSTF is satisfied that the standard addresses the requirements for a gating exchange standard.

  7. Instant Oracle GoldenGate

    CERN Document Server

    Bruzzese, Tony

    2013-01-01

    Filled with practical, step-by-step instructions and clear explanations for the most important and useful tasks. Get the job done and learn as you go. A how-To book with practical recipes accompanied with rich screenshots for easy comprehension.This is a Packt Instant How-to guide, which provides concise and clear recipes for performing the core task of replication using Oracle GoldenGate.The book is aimed at DBAs from any of popular RDBMS systems such as Oracle, SQL Server, Teradata, Sybase, and so on. The level of detail provides quick applicability to beginners and a handy review for more a

  8. Time complexity and gate complexity

    International Nuclear Information System (INIS)

    Koike, Tatsuhiko; Okudaira, Yosuke

    2010-01-01

    We formulate and investigate the simplest version of time-optimal quantum computation theory (TO-QCT), where the computation time is defined by the physical one and the Hamiltonian contains only one- and two-qubit interactions. This version of TO-QCT is also considered as optimality by sub-Riemannian geodesic length. The work has two aims: One is to develop a TO-QCT itself based on a physically natural concept of time, and the other is to pursue the possibility of using TO-QCT as a tool to estimate the complexity in conventional gate-optimal quantum computation theory (GO-QCT). In particular, we investigate to what extent is true the following statement: Time complexity is polynomial in the number of qubits if and only if gate complexity is also. In the analysis, we relate TO-QCT and optimal control theory (OCT) through fidelity-optimal computation theory (FO-QCT); FO-QCT is equivalent to TO-QCT in the limit of unit optimal fidelity, while it is formally similar to OCT. We then develop an efficient numerical scheme for FO-QCT by modifying Krotov's method in OCT, which has a monotonic convergence property. We implemented the scheme and obtained solutions of FO-QCT and of TO-QCT for the quantum Fourier transform and a unitary operator that does not have an apparent symmetry. The former has a polynomial gate complexity and the latter is expected to have an exponential one which is based on the fact that a series of generic unitary operators has an exponential gate complexity. The time complexity for the former is found to be linear in the number of qubits, which is understood naturally by the existence of an upper bound. The time complexity for the latter is exponential in the number of qubits. Thus, both the targets seem to be examples satisfyng the preceding statement. The typical characteristics of the optimal Hamiltonians are symmetry under time reversal and constancy of one-qubit operation, which are mathematically shown to hold in fairly general situations.

  9. Thallium-201 myocardial imaging in acute-myocardial infarction

    International Nuclear Information System (INIS)

    Wackers, F.J.Th.; Lie, K.I.; Sokole, E.B.; Wellens, H.J.J.; Samson, G.; Schoot, J.B. van der

    1980-01-01

    Thallium-201 scintigraphy has proven to be an early and highly sensitive technique to detect myocardial perfusion abnormalities in patients with acute myocardial infarction. During the early phase of acute myocardial infarction, patients may be hemodynamically and electrically unstable. Therefore, scintigraphy is performed preferably at the bed side in the Coronary Care Unit using a mobile gamma camera. Additionally, in order to shorten imaging time in these often critically ill patients, the authors recommend injecting no less than 2 mCi of 201 Tl. Using this dosage, the imaging time per view will be approximately five minutes. Routinely, three views are taken: the first view is a supine 45 0 left-anterior-oblique view, followed by a supine anterior view and finally a left-lateral view, the latter with the patient turned on the right side. (Auth.)

  10. Applicability of myocardial perfusion scintigraphy in the evaluation of cardiac synchronization

    Energy Technology Data Exchange (ETDEWEB)

    Reis, Christiane Cigagna Wiefels; Nascimento, Erivelton Alessandro do; Dias, Fernanda Baptista Ribeiro; Ribeiro, Mario Luiz; Wanderley, Annelise Passos Bispo; Batista, Layanara Albino; Nunes, Thais Helena Peixoto; Mesquita, Claudio Tinoco, E-mail: chriswreis@gmail.com [Universidade Federal Fluminense (UFF), Niterói, RJ (Brazil). Hospital Universitário Antônio Pedro

    2017-07-15

    To systematically assess the literature on the applicability of myocardial perfusion scintigraphy with phase analysis in the investigation of cardiac dyssynchrony and in the selection of patients for cardiac resynchronization therapy (CRT), manuscripts published on the PubMed database over the past five years have been reviewed. The following MeSH terms were used: heart failure, left ventricular, dyssynchrony, gated-SPECT, phase analysis and resynchronization therapy. Altogether, 99 manuscripts were included for discussion. Speckle-tracking echocardiography is still widely used in the evaluation of dyssynchrony, but the advent of myocardial perfusion scintigraphy with the phase analysis technique has been gaining ground, as besides being operator independent, it can evaluate myocardial viability in the same test. Its use became more widespread in patients with left bundle branch block, with recommendation of CRT. Phase analysis also allows evaluating, in a highly reproducible way, the last ventricular segment to contract, hence allowing the best positioning of the CRT electrode. Knowing that the presence, location and extent of fibrosis in the left ventricle, associated with dyssynchrony are determinants of response to resynchronization therapy, GATED- SPECT can provide this information in a single test and in a reproducible and accurate way. Phase histogram offers several parameters that provide greater sensitivity and specificity to the method. It seems that the technique is able to add value both in the selection and in the evaluation of response of patients eligible to CRT. Further studies are being conducted to demonstrate its clinical applicability. (author)

  11. Evaluation of prognosis and quality of life in patients with myocardial infarction by cardiac nuclear medicine

    International Nuclear Information System (INIS)

    Nakamura, Mototoshi; Kondo, Takesi; Tachiki, Syuichi

    1994-01-01

    The present study was designed to evaluate the value of cardiac nuclear medicine in the evaluation of prognosis and quality of life (QOL) in chronic stage in patients with myocardial infarction (MI). The subjects were 909 MI patients who were admitted to CCU and underwent Tl-201 myocardial imaging (n=593), Tc-99m PYP myocardial imaging (n=582) and gated blood pool imaging (n=577) and whose records were available concerning life or death as of January 23, 1992. On Tl-201 and Tc-99m PYP images, Tl-201 defect and abnormal uptake of Tc-99m PYP were visually interpreted as large, middle and small; and on gated blood pool images, less than 30% of ejection fraction (EF) was defined as severe, 30-50% of EF as moderate and 50% or more of EF as normal. Survival rate was low in the group of patients having large Tl-201 defect and Tc-99m PYP uptake. In addition, patients in this group tended to be resigned. The presence or absence of right ventricular infarction on PYP images and the severity of Parkey's classification were independent upon survival rate. Survival rate was significantly lower in the group of patients unable to receive cardiac nuclear medicine than in the group of patients receiving it. Cardiac nuclear medicine performed in the subacute phase was considered useful in evaluating prognosis of MI patients and QOL in the chronic phase. (N.K.)

  12. Angiographic assessment of reperfusion in acute myocardial infarction by myocardial blush grade

    NARCIS (Netherlands)

    Henriques, JPS; Zijlstra, F; van 't Hof, AWJ; de Boer, MJ; Gosselink, M; Hoorntje, JCA; Suryapranata, H; Dambrink, Jan Hendrik Everwijn

    2003-01-01

    Background-Angiographic successful reperfusion in acute myocardial infarction has been defined as TIMI 3 flow. However, TIMI 3 flow does not always result in effective myocardial reperfusion. Myocardial blush grade (MBG) is an angiographic measure of myocardial perfusion. We hypothesized that

  13. Angiographic assessment of reperfusion in acute myocardial infarction by myocardial blush grade

    NARCIS (Netherlands)

    Henriques, Jose P. S.; Zijlstra, Felix; van 't Hof, Arnoud W. J.; de Boer, Menko-Jan; Dambrink, Jan-Henk E.; Gosselink, Marcel; Hoorntje, Jan C. A.; Suryapranata, Harry

    2003-01-01

    Angiographic successful reperfusion in acute myocardial infarction has been defined as TIMI 3 flow. However, TIMI 3 flow does not always result in effective myocardial reperfusion. Myocardial blush grade (MBG) is an angiographic measure of myocardial perfusion. We hypothesized that optimal

  14. Value of gated SPECT in the analysis of regional wall motion of the interventricular septum after coronary artery bypass grafting

    International Nuclear Information System (INIS)

    Giubbini, Raffaele; Rossini, Pierluigi; Bertagna, Francesco; Bosio, Giovanni; Paghera, Barbara; Pizzocaro, Claudio; Canclini, Silvana; Terzi, Arturo; Germano, Guido

    2004-01-01

    The aim of this study was the evaluation of septal wall motion, perfusion and wall thickening after CABG in two groups of consecutive patients, one with grafted left anterior coronary artery and no history of myocardial infarction, and the other with previous anteroseptal myocardial infarction and impaired septal motion before surgery. The issue addressed was the ability of gated SPECT to differentiate between true paradoxical septal motion, characterised by paradoxical wall motion, depressed ejection fraction (EF), poor viability and compromised wall thickening, and pseudo-paradoxical motion, characterised by abnormal wall motion and regional EF but preserved perfusion and wall thickening. One hundred and thirty-two patients with previous anterior myocardial infarction, 82 patients with left anterior descending coronary disease and no history of myocardial infarction and 27 normal subjects underwent rest gated SPECT after 99m Tc-sestamibi injection, according to the standard QGS protocol. Quantitative regional EF, regional perfusion, regional wall motion and regional wall thickening were determined using a 20-segment model. Despite the presence of similar regional wall motion impairment in patients with and patients without septal infarction, in terms of regional EF (2.5%±3% vs 1.9%±4.9% p=NS) and inward septal motion (3±4.9 mm vs 2.3±6.1 mm p=NS), significant differences were observed in both perfusion (74.7%±6.2% vs 63.3%±13%, p>0.0001) and regional wall thickening (17.2%±7.4% vs 12.6%±7.2%, p>0.0001). Gated SPECT with perfusion tracers can reliably differentiate pseudo-paradoxical from true paradoxical septal motion in patients with previous CABG, and it may be the method of choice for evaluating left ventricular performance in this patient population. (orig.)

  15. Value of gated SPECT in the analysis of regional wall motion of the interventricular septum after coronary artery bypass grafting

    Energy Technology Data Exchange (ETDEWEB)

    Giubbini, Raffaele; Rossini, Pierluigi; Bertagna, Francesco; Bosio, Giovanni; Paghera, Barbara; Pizzocaro, Claudio; Canclini, Silvana; Terzi, Arturo [Spedali Civili di Brescia, Department of Nuclear Medicine, Brescia (Italy); Germano, Guido [Cedars-Sinai Medical Center, Artificial Intelligence Program, Department of Medicine, Los Angeles, CA (United States)

    2004-10-01

    The aim of this study was the evaluation of septal wall motion, perfusion and wall thickening after CABG in two groups of consecutive patients, one with grafted left anterior coronary artery and no history of myocardial infarction, and the other with previous anteroseptal myocardial infarction and impaired septal motion before surgery. The issue addressed was the ability of gated SPECT to differentiate between true paradoxical septal motion, characterised by paradoxical wall motion, depressed ejection fraction (EF), poor viability and compromised wall thickening, and pseudo-paradoxical motion, characterised by abnormal wall motion and regional EF but preserved perfusion and wall thickening. One hundred and thirty-two patients with previous anterior myocardial infarction, 82 patients with left anterior descending coronary disease and no history of myocardial infarction and 27 normal subjects underwent rest gated SPECT after {sup 99m}Tc-sestamibi injection, according to the standard QGS protocol. Quantitative regional EF, regional perfusion, regional wall motion and regional wall thickening were determined using a 20-segment model. Despite the presence of similar regional wall motion impairment in patients with and patients without septal infarction, in terms of regional EF (2.5%{+-}3% vs 1.9%{+-}4.9% p=NS) and inward septal motion (3{+-}4.9 mm vs 2.3{+-}6.1 mm p=NS), significant differences were observed in both perfusion (74.7%{+-}6.2% vs 63.3%{+-}13%, p>0.0001) and regional wall thickening (17.2%{+-}7.4% vs 12.6%{+-}7.2%, p>0.0001). Gated SPECT with perfusion tracers can reliably differentiate pseudo-paradoxical from true paradoxical septal motion in patients with previous CABG, and it may be the method of choice for evaluating left ventricular performance in this patient population. (orig.)

  16. Cryoinjury : a model of myocardial regeneration

    NARCIS (Netherlands)

    van Amerongen, Machteld J.; Hamsen, Martin C.; Petersen, Arien H.; Popa, Eliane R.; van Luyn, Marja J. A.

    2008-01-01

    Introduction: Although traditionally adult cardiomyocytes are thought to be unable to divide, recent observations provide evidence for cardiomyocyte proliferation after myocardial injury. Myocardial cryoinjury has been shown to be followed by neovascularization. We hypothesize that, in addition to

  17. Regional myocardial extraction of a radioiodinated branched chain fatty acid during right ventricular pressure overload due to acute pulmonary hypertension

    International Nuclear Information System (INIS)

    Hurford, W.; Lowenstein, E.; Zapol, W.; Barlai-Kovach, M.; Livni, E.; Elmaleh, D.R.; Strauss, H.W.

    1985-01-01

    To determine whether branched chain fatty acid extraction is reduced during right ventricular (RV) dysfunction due to acute pulmonary artery hypertension, studies were done in 6 anesthetized dogs. Regional branched chain fatty acid extraction was measured by comparing the myocardial uptake of I-125 labeled 15-[p-(iodophenyl)]-3-methylpentadecanoic acid (I-PDA) to myocardial blood flow. Acute pulmonary hypertension was induced by incremental intravenous injection of 100 micron diameter glass beads into six pentobarbital anesthetized, mechanically ventilated dogs. Myocardial blood flow was measured by radiolabeled microspheres both under baseline conditions and during pulmonary hypertension. Mean RV pressure rose from 12 +- 2 (mean +- SEM) to 30 +-3mmHg resulting in a 225 +- 16% increase in RV stroke work. RV ejection fraction, as assessed by gated blood pool scans fell from 39 +- 2 to 18 +- 2%. Left ventricular (LV) pressures, stroke work and ejection fraction were unchanged. Myocardial blood flow increased 132 + 59% in the RV free wall and 67 +- 22% in the RV septum. LV blood flow was unchanged. Despite increased RV work and myocardial blood flow, no differences were noted in the branched chain fatty acid extraction ratios among LV or RV free walls or septum. The authors conclude that early RV dysfunction associated with pulmonary artery hypertension is not due to inadequate myocardial blood flow or branched chain fatty acid extraction

  18. Influence of Respiratory Gating, Image Filtering, and Animal Positioning on High-Resolution Electrocardiography-Gated Murine Cardiac Single-Photon Emission Computed Tomography

    Directory of Open Access Journals (Sweden)

    Chao Wu

    2015-01-01

    Full Text Available Cardiac parameters obtained from single-photon emission computed tomographic (SPECT images can be affected by respiratory motion, image filtering, and animal positioning. We investigated the influence of these factors on ultra-high-resolution murine myocardial perfusion SPECT. Five mice were injected with 99m technetium (99mTc-tetrofosmin, and each was scanned in supine and prone positions in a U-SPECT-II scanner with respiratory and electrocardiographic (ECG gating. ECG-gated SPECT images were created without applying respiratory motion correction or with two different respiratory motion correction strategies. The images were filtered with a range of three-dimensional gaussian kernels, after which end-diastolic volumes (EDVs, end-systolic volumes (ESVs, and left ventricular ejection fractions were calculated. No significant differences in the measured cardiac parameters were detected when any strategy to reduce or correct for respiratory motion was applied, whereas big differences (> 5% in EDV and ESV were found with regard to different positioning of animals. A linear relationship (p < .001 was found between the EDV or ESV and the kernel size of the gaussian filter. In short, respiratory gating did not significantly affect the cardiac parameters of mice obtained with ultra-high-resolution SPECT, whereas the position of the animals and the image filters should be the same in a comparative study with multiple scans to avoid systematic differences in measured cardiac parameters.

  19. Boolean gates on actin filaments

    Energy Technology Data Exchange (ETDEWEB)

    Siccardi, Stefano, E-mail: ssiccardi@2ssas.it [The Unconventional Computing Centre, University of the West of England, Bristol (United Kingdom); Tuszynski, Jack A., E-mail: jackt@ualberta.ca [Department of Oncology, University of Alberta, Edmonton, Alberta (Canada); Adamatzky, Andrew, E-mail: andrew.adamatzky@uwe.ac.uk [The Unconventional Computing Centre, University of the West of England, Bristol (United Kingdom)

    2016-01-08

    Actin is a globular protein which forms long polar filaments in the eukaryotic cytoskeleton. Actin networks play a key role in cell mechanics and cell motility. They have also been implicated in information transmission and processing, memory and learning in neuronal cells. The actin filaments have been shown to support propagation of voltage pulses. Here we apply a coupled nonlinear transmission line model of actin filaments to study interactions between voltage pulses. To represent digital information we assign a logical TRUTH value to the presence of a voltage pulse in a given location of the actin filament, and FALSE to the pulse's absence, so that information flows along the filament with pulse transmission. When two pulses, representing Boolean values of input variables, interact, then they can facilitate or inhibit further propagation of each other. We explore this phenomenon to construct Boolean logical gates and a one-bit half-adder with interacting voltage pulses. We discuss implications of these findings on cellular process and technological applications. - Highlights: • We simulate interaction between voltage pulses using on actin filaments. • We use a coupled nonlinear transmission line model. • We design Boolean logical gates via interactions between the voltage pulses. • We construct one-bit half-adder with interacting voltage pulses.

  20. How reliable is myocardial imaging in the diagnosis of acute myocardial infarction

    International Nuclear Information System (INIS)

    Willerson, J.T.

    1983-01-01

    Myocardial scintigraphic techniques available presently allow a sensitive and relatively specific diagnosis of acute myocardial infarction when they are used correctly, although every technique has definite limitations. Small myocardial infarcts (less than 3 gm.) may be missed, and there are temporal limitations in the usefulness of the scintigraphic techniques. The development of tomographic methodology that may be used with single-photon radionuclide emitters (including technetium and 201 Tl will allow the detection of relatively small abnormalities in myocardial perfusion and regions of myocardial infarction and will help to provide a more objective interpretation of the myocardial scintigrams. The use of overlay techniques allowing simultaneous assessment of myocardial perfusion, infarct-avid imaging, and radionuclide ventriculograms will provide insight into the relevant aspects of the extent of myocardial damage, the relationship of damage to myocardial perfusion, and the functional impact of myocardial infarction on ventricular performance

  1. Myocardial infarction after near drowning.

    Science.gov (United States)

    Chen, Li-Bang; Lai, Yen-Chun; Chen, Chang-Chih; Chang, Wen-Han; Su, Yu-Jang

    2008-06-01

    During summer, near drowning is a common accident in Taiwan. It may lead to multiple organ damages in cases where severe hypothermia and hypoxemia occur. We present a case of myocardial infarction after near drowning. The patient was sent to our ED by the emergency medical services called by the witness. On arrival to our ED, hypothermia and hypoxemia overcame him. Endotracheal intubation and warm intravenous fluid were applied at once owing to drowsy consciousness, respiratory distress, and hypothermia. Electrocardiogram showed diffuse ST-segment elevation over the precordial leads V2-V6. The initial level of cardiac enzymes was within normal limit but elevated in troponin I on the second day after hospitalization. We presumed that the possibility of myocardial infarction resulted from near drowning-related hypoxemia. To our knowledge, this is the first case describing myocardial injury with electrocardiogram changes after near drowning.

  2. Myocardial perfusion modeling using MRI

    DEFF Research Database (Denmark)

    Larsson, H B; Fritz-Hansen, T; Rostrup, Egill

    1996-01-01

    In the present study, it is shown that it is possible to quantify myocardial perfusion using magnetic resonance imaging in combination with gadolinium diethylenetriaminopentaacetic acid (Gd-DTPA). Previously, a simple model and method for measuring myocardial perfusion using an inversion recovery...... of Gd-DTPA (lambda), the vascular blood volume (Vb), and the time delay through the coronary arteries (delta T). The model was evaluated by computer simulation and used on experimental results from seven healthy subjects. The results in the healthy volunteers for a region of interest placed...... in the anterior myocardial wall were (mean +/- SD) Ki = 54 +/- 10 ml/100 g/min, lambda = 30 +/- 3 ml/100 g, Vb = 9 +/- 2 ml/100 g, delta T = 3.2 +/- 1.1 s. These results are in good agreement with similar results obtained by other methods....

  3. Dynamic CT myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Caruso, Damiano [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiological Sciences, Oncological and Pathological Sciences, University of Rome “Sapienza”, Latina (Italy); Eid, Marwen [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States); Jin, Kwang Nam [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiology, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul (Korea, Republic of); Varga-Szemes, Akos [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Tesche, Christian [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Cardiology and Intensive Care Medicine, Heart Center Munich-Bogenhausen, Munich (Germany); Mangold, Stefanie [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, Tuebingen (Germany); and others

    2016-10-15

    Highlights: • CT myocardial perfusion provides functional assessment of the myocardium. • CCTA is limited in determining the hemodynamic significance of coronary stenosis. • CT-MPI can accurately detect hemodynamically significant coronary artery stenosis. - Abstract: Non-invasive cardiac imaging has rapidly evolved during the last decade due to advancements in CT based technologies. Coronary CT angiography has been shown to reliably assess coronary anatomy and detect high risk coronary artery disease. However, this technique is limited to anatomical assessment, thus non-invasive techniques for functional assessment of the heart are necessary. CT myocardial perfusion is a new CT based technique that provides functional assessment of the myocardium and allows for a comprehensive assessment of coronary artery disease with a single modality when combined with CTA. This review aims to discuss dynamic CT myocardial perfusion as a new technique in the assessment of CAD.

  4. Inflammatory Response During Myocardial Infarction.

    Science.gov (United States)

    Oliveira, Joaquim B; Soares, Alexandre A S M; Sposito, Andrei C

    2018-01-01

    The occlusion of a coronary artery by a thrombus generated on a ruptured atherosclerotic plaque has been pursued in the last decades as a determining event for the clinical outcome after myocardial infarction (MI). Yet, MI causes a cell death wave front, which triggers an inflammatory response to clear cellular debris, and which in excess can double the myocardial lesion and influence the clinical prognosis in the short and long term. Accordingly, proper, timely regulated inflammatory response has now been considered a second pivotal player in cardiac recovery after MI justifying the search for pharmacological strategies to modulate inflammatory effectors. This chapter reviews the key events and the main effectors of inflammation after myocardial ischemic insult, as well as the contribution of this phenomenon to the progression of atherosclerosis. © 2018 Elsevier Inc. All rights reserved.

  5. Morphological aspects of myocardial bridges.

    Science.gov (United States)

    Lujinović, Almira; Kulenović, Amela; Kapur, Eldan; Gojak, Refet

    2013-11-01

    Although some myocardial bridges can be asymptomatic, their presence often causes coronary disease either through direct compression of the "tunnel" segment or through stimulation and accelerated development of atherosclerosis in the segment proximally to the myocardial bridge. The studied material contained 30 human hearts received from the Department of Anatomy. The hearts were preserved 3 to 5 days in 10% formalin solution. Thereafter, the fatty tissue was removed and arterial blood vessels prepared by careful dissection with special reference to the presence of the myocardial bridges. Length and thickness of the bridges were measured by the precise electronic caliper. The angle between the myocardial bridge fibre axis and other axis of the crossed blood vessel was measured by a goniometer. The presence of the bridges was confirmed in 53.33% of the researched material, most frequently (43.33%) above the anterior interventricular branch. The mean length of the bridges was 14.64 ± 9.03 mm and the mean thickness was 1.23 ± 1.32 mm. Myocardial bridge fibres pass over the descending blood vessel at the angle of 10-90 degrees. The results obtained on a limited sample suggest that the muscular index of myocardial bridge is the highest for bridges located on RIA, but that the difference is not significant in relation to bridges located on other branches. The results obtained suggest that bridges located on other branches, not only those on RIA, could have a great contractive power and, consequently, a great compressive force, which would be exerted on the wall of a crossed blood vessel.

  6. Morphological aspects of myocardial bridges

    Directory of Open Access Journals (Sweden)

    Almira Lujinović

    2013-11-01

    Full Text Available Although some myocardial bridges can be asymptomatic, their presence often causes coronary disease either through direct compression of the “tunnel” segment or through stimulation and accelerated development of atherosclerosis in the segment proximally to the myocardial bridge. The studied material contained 30 human hearts received from the Department of Anatomy. The hearts were preserved 3 to 5 days in 10% formalin solution. Thereafter, the fatty tissue was removed and arterial blood vessels prepared by careful dissection with special reference to the presence of the myocardial bridges. Length and thickness of the bridges were measured by the precise electronic caliper. The angle between the myocardial bridge fibre axis and other axis of the crossed blood vessel was measured by a goniometer. The presence of the bridges was confirmed in 53.33% of the researched material, most frequently (43.33% above the anterior interventricular branch. The mean length of the bridges was 14.64±9.03 mm and the mean thickness was 1.23±1.32 mm. Myocardial bridge fibres pass over the descending blood vessel at the angle of 10-90 degrees. The results obtained on a limited sample suggest that the muscular index of myocardial bridge is the highest for bridges located on RIA, but that the difference is not significant in relation to bridges located on other branches. The results obtained suggest that bridges located on other branches, not only those on RIA, could have a great contractive power and, consequently, a great compressive force, which would be exerted on the wall of a crossed blood vessel.

  7. A gate drive circuit for gate-turn-off (GTO) devices in series stack

    International Nuclear Information System (INIS)

    Despe, O.

    1999-01-01

    A gate-turn-off (GTO) switch is under development at the Advanced Photon Source as a replacement for a thyratron switch in high power pulsed application. The high voltage in the application requires multiple GTOs connected in series. One component that is critical to the success of GTO operation is the gate drive circuit. The gate drive circuit has to provide fast high-current pulses to the GTO gate for fast turn-on and turn-off. It also has to be able to operate while floating at high voltage. This paper describes a gate drive circuit that meets these requirements

  8. Terahertz amplification in RTD-gated HEMTs with a grating-gate wave coupling topology

    Energy Technology Data Exchange (ETDEWEB)

    Condori Quispe, Hugo O.; Sensale-Rodriguez, Berardi [The University of Utah, Salt Lake City, Utah 84112 (United States); Encomendero-Risco, Jimy J.; Xing, Huili Grace [University of Notre Dame, Notre Dame, Indiana 46556 (United States); Cornell University, Ithaca, New York 14853 (United States)

    2016-08-08

    We theoretically analyze the operation of a terahertz amplifier consisting of a resonant-tunneling-diode gated high-electron-mobility transistor (RTD-gated HEMT) in a grating-gate topology. In these devices, the key element enabling substantial power gain is the efficient coupling of terahertz waves into and out of plasmons in the RTD-gated HEMT channel, i.e., the gain medium, via the grating-gate itself, part of the active device, rather than by an external antenna structure as discussed in previous works, therefore potentially enabling terahertz amplification with associated power gains >40 dB.

  9. Assessment of myocardial perfusion using a new scanning agent

    Energy Technology Data Exchange (ETDEWEB)

    Khalil, M.N

    1987-01-01

    This work assessed a new compound: Tc-99m tertiary butyl isonitrile (T-BIN) in scanning the normal myocardium in dogs. Experimentally induced myocardial infarcts (M.I.) were detected. The compound cleared significantly from the blood within 15 minutes and from the lungs within an hour after intravenous administration. Liver uptake was high and remained so. Cardiac uptake occurred quickly and continued for 6 hours. Comparable results were obtained in normal humans and patients. Myocardial scanning was best after 60 minutes at rest or 30 minutes after exercise. Liver uptake sometimes obscured the detection of inferior M.I. but this problem was reduced using a 45/sup 0/ left anterior oblique view with a 20/sup 0/ cranial tilt. At rest 9/10 patients with M.I. showed defects corresponding to the infarct sites. In 20 patients with angina pectoris 16 had perfusion defects on exercise. In 15/16 patients reversible ischaemia was demonstrated. The reperfusion scans were best obtained at 4 hours post exercise. Both Tl-201 and T-BIN detected equally the infarcts (3/3) but in patients with angina 8/10 with T-BIN and 6/10 with Tl-201 showed defects. ECG gating of the T-BIN scans was also studied.

  10. Coronary artery calcium scoring in myocardial infarction

    International Nuclear Information System (INIS)

    Beslic, S.; Dalagija, F.

    2005-01-01

    Background. The aim of this study was to evaluate coronary artery calcium scoring and the assessment of the risk factors in patients with myocardial infarction (MI). Methods. During the period of three years, 27 patients with MI were analyzed. The average age of patients was 66.1 years (46 to 81). Coronary arteries calcium was evaluated by multi row detector computed tomography (MTDC) S omatom Volume Zoom Siemens , and, retrospectively by ECG gating data acquisition. Semi automated calcium quantification to calculate Agatston calcium score (CS) was performed with 4 x 2.5 mm collimation, using 130 ml of contrast medium, injected with an automatic injector, with the flow rate of 4 ml/sec. The delay time was determined empirically. At the same time several risk factors were evaluated. Results. Out of 27 patients with MI, 3 (11.1%) patients had low CS (10- 100), 5 (18.5%) moderate CS (101- 499), and 19 (70.4%) patients high CS (>500). Of risk factors, smoking was confirmed in 17 (63.0%), high blood pressure (HTA) in 10 (57.0%), diabetes mellitus in 7 (25.9%), positive family history in 5 (18.5%), pathological lipids in 5 (18.5%), alcohol abuse in 4 (1.8%) patients. Six (22.2%) patients had symptoms of angina pectoris. Conclusions. The research showed high correlation of MI and high CS (>500). Smoking, HTA, diabetes mellitus, positive family history and hypercholesterolemia are significant risk factors. Symptoms are relatively poor in large number of patients. (author)

  11. Gates Auto Door Car With Lights Modulated

    OpenAIRE

    Lina Carolina; Luyung Dinani, Skom, MMSi

    2002-01-01

    In scientific writing wi ll be explained about automatic gates with modulated headlights, where to find the car lights were adjusted by the relative frequency darker because of this background that the author alleviate human task in performing daily activities by using an automatic gate with the car lights modulated.

  12. Protected gates for topological quantum field theories

    Science.gov (United States)

    Beverland, Michael E.; Buerschaper, Oliver; Koenig, Robert; Pastawski, Fernando; Preskill, John; Sijher, Sumit

    2016-02-01

    We study restrictions on locality-preserving unitary logical gates for topological quantum codes in two spatial dimensions. A locality-preserving operation is one which maps local operators to local operators — for example, a constant-depth quantum circuit of geometrically local gates, or evolution for a constant time governed by a geometrically local bounded-strength Hamiltonian. Locality-preserving logical gates of topological codes are intrinsically fault tolerant because spatially localized errors remain localized, and hence sufficiently dilute errors remain correctable. By invoking general properties of two-dimensional topological field theories, we find that the locality-preserving logical gates are severely limited for codes which admit non-abelian anyons, in particular, there are no locality-preserving logical gates on the torus or the sphere with M punctures if the braiding of anyons is computationally universal. Furthermore, for Ising anyons on the M-punctured sphere, locality-preserving gates must be elements of the logical Pauli group. We derive these results by relating logical gates of a topological code to automorphisms of the Verlinde algebra of the corresponding anyon model, and by requiring the logical gates to be compatible with basis changes in the logical Hilbert space arising from local F-moves and the mapping class group.

  13. Protected gates for topological quantum field theories

    Energy Technology Data Exchange (ETDEWEB)

    Beverland, Michael E.; Pastawski, Fernando; Preskill, John [Institute for Quantum Information and Matter, California Institute of Technology, Pasadena, California 91125 (United States); Buerschaper, Oliver [Dahlem Center for Complex Quantum Systems, Freie Universität Berlin, 14195 Berlin (Germany); Koenig, Robert [Institute for Advanced Study and Zentrum Mathematik, Technische Universität München, 85748 Garching (Germany); Sijher, Sumit [Institute for Quantum Computing and Department of Applied Mathematics, University of Waterloo, Waterloo, Ontario N2L 3G1 (Canada)

    2016-02-15

    We study restrictions on locality-preserving unitary logical gates for topological quantum codes in two spatial dimensions. A locality-preserving operation is one which maps local operators to local operators — for example, a constant-depth quantum circuit of geometrically local gates, or evolution for a constant time governed by a geometrically local bounded-strength Hamiltonian. Locality-preserving logical gates of topological codes are intrinsically fault tolerant because spatially localized errors remain localized, and hence sufficiently dilute errors remain correctable. By invoking general properties of two-dimensional topological field theories, we find that the locality-preserving logical gates are severely limited for codes which admit non-abelian anyons, in particular, there are no locality-preserving logical gates on the torus or the sphere with M punctures if the braiding of anyons is computationally universal. Furthermore, for Ising anyons on the M-punctured sphere, locality-preserving gates must be elements of the logical Pauli group. We derive these results by relating logical gates of a topological code to automorphisms of the Verlinde algebra of the corresponding anyon model, and by requiring the logical gates to be compatible with basis changes in the logical Hilbert space arising from local F-moves and the mapping class group.

  14. Multi-gated field emitters for a micro-column

    International Nuclear Information System (INIS)

    Mimura, Hidenori; Kioke, Akifumi; Aoki, Toru; Neo, Yoichiro; Yoshida, Tomoya; Nagao, Masayoshi

    2011-01-01

    We have developed a multi-gated field emitter (FE) such as a quadruple-gated FE with a three-stacked electrode lens and a quintuple-gated FE with a four-stacked electrode lens. Both the FEs can focus the electron beam. However, the quintuple-gated FE has a stronger electron convergence than the quadruple-gated FE, and a beam crossover is clearly observed for the quintuple-gated FE.

  15. Top-gate pentacene-based organic field-effect transistor with amorphous rubrene gate insulator

    Science.gov (United States)

    Hiroki, Mizuha; Maeda, Yasutaka; Ohmi, Shun-ichiro

    2018-02-01

    The scaling of organic field-effect transistors (OFETs) is necessary for high-density integration and for this, OFETs with a top-gate configuration are required. There have been several reports of damageless lithography processes for organic semiconductor or insulator layers. However, it is still difficult to fabricate scaled OFETs with a top-gate configuration. In this study, the lift-off process and the device characteristics of the OFETs with a top-gate configuration utilizing an amorphous (α) rubrene gate insulator were investigated. We have confirmed that α-rubrene shows an insulating property, and its extracted linear mobility was 2.5 × 10‑2 cm2/(V·s). The gate length and width were 10 and 60 µm, respectively. From these results, the OFET with a top-gate configuration utilizing an α-rubrene gate insulator is promising for the high-density integration of scaled OFETs.

  16. Materials Fundamentals of Gate Dielectrics

    CERN Document Server

    Demkov, Alexander A

    2006-01-01

    This book presents materials fundamentals of novel gate dielectrics that are being introduced into semiconductor manufacturing to ensure the continuous scalling of the CMOS devices. This is a very fast evolving field of research so we choose to focus on the basic understanding of the structure, thermodunamics, and electronic properties of these materials that determine their performance in device applications. Most of these materials are transition metal oxides. Ironically, the d-orbitals responsible for the high dielectric constant cause sever integration difficulties thus intrinsically limiting high-k dielectrics. Though new in the electronics industry many of these materials are wel known in the field of ceramics, and we describe this unique connection. The complexity of the structure-property relations in TM oxides makes the use of the state of the art first-principles calculations necessary. Several chapters give a detailed description of the modern theory of polarization, and heterojunction band discont...

  17. Dosimetry in myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Toledo, Janine M.; Trindade, Bruno; Ribeiro, Tarcisio P.C.

    2011-01-01

    This paper conducts a dosimetric investigation on the myocardial perfusion image protocol, together with a literature reviewing, motivated by the significant statistic increasing on mortality, morbidity and disability associated with cardiovascular disease, surpassing infectious diseases. Nuclear Cardiology plays a role n the diagnostic functional evaluation of the heart and in the prognostic of patients with suspected or known cardiac ischemia. In the context of unstable myocardial ischemic syndrome, myocardial perfusion scintigraphy is a non-invasive procedure performed by administering a radiopharmaceutical targeted to the heart. As tool for this study are that the images obtained by thoracic angiotomography and abdominal aorta as a anatomic and functional information for model reproduction in SISCODES - System of Codes for Absorbed Dose Calculations based on Stochastic Methods. Data were manipulated in order to create a voxel computational model of the heart to be running in MCNP - Monte Carlo Neutron Particle Code. . It was assumed a homogeneous distribution of Tl-201 in cardiac muscle. Simulations of the transport of particles through the voxel and the interaction with the heart tissue were performed. As a result, the isodose curves in the heart model are displayed as well as the dose versus volume histogram of the heart muscle. We conclude that the present computational tools can generate doses distributed in myocardial perfusion. (author)

  18. Perceived stress in myocardial infarction

    NARCIS (Netherlands)

    Arnold, Suzanne V.; Smolderen, K.G.E.; Buchanan, Donna M.; Li, Yan; Spertus, John A.

    2012-01-01

    Objectives This study sought to determine the association of chronic stress with long-term adverse outcomes after acute myocardial infarction (AMI).BackgroundChronic stress has been shown to be associated with the development of cardiovascular disease and, in the case of particular types of stress

  19. The Orchestra of Myocardial Regeneration

    NARCIS (Netherlands)

    Siddiqi, S.

    2014-01-01

    A glimpse on previous and current literature ignites the recognition of the luxurious era that cardiac science has reached. In particular, the past fifteen years have provided tremendous advancements in the field of myocardial biology with the characterization of cardiac stem cells, reprogramming of

  20. Myocardial perfusion at fatal infarction

    DEFF Research Database (Denmark)

    Hvid-Jacobsen, K; Møller, J T; Kjøller, E

    1992-01-01

    In a consecutive study of myocardial scintigraphy in acute ischemic syndrome, four patients had 99mTc-hexamibi injected intravenously before they developed fatal cardiogenic shock. Planar scintigraphy was performed after death. Slices of the hearts after autopsy were analyzed for scintigraphic...

  1. Spousal Adjustment to Myocardial Infarction.

    Science.gov (United States)

    Ziglar, Elisa J.

    This paper reviews the literature on the stresses and coping strategies of spouses of patients with myocardial infarction (MI). It attempts to identify specific problem areas of adjustment for the spouse and to explore the effects of spousal adjustment on patient recovery. Chapter one provides an overview of the importance in examining the…

  2. Pregnancy-related myocardial infarction

    NARCIS (Netherlands)

    Lameijer, H.; Lont, M. C.; Buter, H.; van Boven, A. J.; Boonstra, P. W.; Pieper, P. G.

    Introduction The risk of acute myocardial infarction in young women is low, but increases during pregnancy due to the physiological changes in pregnancy, including hypercoagulability. Ischaemic heart disease during pregnancy is not only associated with increased maternal morbidity and mortality, but

  3. Neonatal Myocardial Infarction or Myocarditis?

    NARCIS (Netherlands)

    de Vetten, Leanne; Bergman, Klasien A.; Elzenga, Nynke J.; van Melle, Joost P.; Timmer, Albertus; Bartelds, Beatrijs

    We report a 29 week-gestation preterm infant who presented during his second week of life with cardiogenic shock. Clinical presentation and first diagnostics suggested myocardial infarction, but echocardiographic features during follow-up pointed to a diagnosis of enteroviral myocarditis. The child

  4. Thrombolysis in acute myocardial infarction

    NARCIS (Netherlands)

    F. Vermeer (Frank)

    1987-01-01

    textabstractThe purpose of this study was to analyse the effects of thrombolytic therapy with intracoronary streptokinase in patients with acute myocardial infarction. Five centres participated in the study, the Thorax center in Rotterdam (237 patients), the Academic Hospital of the Free

  5. Dosimetry in myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Toledo, Janine M.; Trindade, Bruno; Ribeiro, Tarcisio P.C. [Universidade Federal de Minas Gerais (DEN/UFMG), Belo Horizonte (Brazil). Dept. de Engenharia Nuclear. Programa de Pos-Graduacao em Ciencias e Tecnicas Nucleares

    2011-07-01

    This paper conducts a dosimetric investigation on the myocardial perfusion image protocol, together with a literature reviewing, motivated by the significant statistic increasing on mortality, morbidity and disability associated with cardiovascular disease, surpassing infectious diseases. Nuclear Cardiology plays a role n the diagnostic functional evaluation of the heart and in the prognostic of patients with suspected or known cardiac ischemia. In the context of unstable myocardial ischemic syndrome, myocardial perfusion scintigraphy is a non-invasive procedure performed by administering a radiopharmaceutical targeted to the heart. As tool for this study are that the images obtained by thoracic angiotomography and abdominal aorta as a anatomic and functional information for model reproduction in SISCODES - System of Codes for Absorbed Dose Calculations based on Stochastic Methods. Data were manipulated in order to create a voxel computational model of the heart to be running in MCNP - Monte Carlo Neutron Particle Code. . It was assumed a homogeneous distribution of Tl-201 in cardiac muscle. Simulations of the transport of particles through the voxel and the interaction with the heart tissue were performed. As a result, the isodose curves in the heart model are displayed as well as the dose versus volume histogram of the heart muscle. We conclude that the present computational tools can generate doses distributed in myocardial perfusion. (author)

  6. Detection of regional derangements in myocardial metabolism by positron computed tomography in Duchenne's muscular dystrophy

    International Nuclear Information System (INIS)

    Henze, E.; Schelbert, H.R.; Perloff, J.K.; Schwaiger, M.; Phelps, M.E.

    1982-01-01

    Duchenne's Muscular Dystrophy is unique in genetically targeting for disease a specific region of myocardium: the postero-basal left ventricular wall. Postmortem examinations revealed focal fibrous degenerations in the postero-basal segment, while the coronary arteries were usually not affected. A predystrophic metabolic fault has been postulated for this region. This hypothesis was tested with positron computed tomography as a new means for the noninvasive study of regional myocadial perfusion and metabolism and to determine the incidence of regional and global left ventricular dysfunction and perfusion abnormalities using Thallium-201 and gated blood pool imaging. Myocardial perfusion was evaluated with N-13 ammonia while regional myocardial glucose uptake was studied with the glucose analog F-18 DG. The sensitivity of each diagnostic test for detecting cardiac involvement in Duchenne's Muscular Dystrophy was evaluated. It was highest for ammonia and glucose imaging and it was low for Thallium and radionuclide blood pool imaging

  7. MR study of acute myocardial infarction with injection of Gd-DOTA (Fifteen patients)

    International Nuclear Information System (INIS)

    Richoz, B.; Delcour, C.; Depelchin, P.; Lenaers, A.; Jacquemin, C.; Gusella, P.; Struyven, J.; Richoz, B.

    1990-01-01

    We studied 15 patients 4 to 8 days after myocardial infarction by using ECG gated MR before and after administration of 0.2 mmol/kg Gd-DOTA. The diagnosis in each patient was confirmed by electrocardiographic criteria, elevated levels of fractionated creatine kinase (CK) isoenzyme, thallium scintigraphy, ventriculography and coronarography. T1-weighted, spin-echo images, were obtained before and immediately after injection of Gd-DOTA and were repeated 15 min later. The site of infarction was visualized in 10 patients as an area of high signal intensity after the injection of Gd-DOTA. Contrast between normal and infarcted myocardium was greatest 15 min after injection. Three patients were excluded because of failure to acquire adequate MR studies. In 2 other patients, the infarct were not detected. Before injection of Gd-DOTA, only 2 infarcts were detected. These results suggest that Gd-DOTA can improve MR visualization and detection of acute myocardial infarction [fr

  8. Cardiovascular magnetic resonance: myocardial perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Nagel, E.; Al-Saadi, N.; Fleck, E. [Dept. of Internal Medicine/Cardiology, German Heart Inst. Berlin and Charite, Campus Virchow, Humboldt Univ. (Germany)

    2000-06-01

    There is growing evidence that the noninvasive assessment of myocardial perfusion with cardiovascular magnetic resonance is a valid and accurate tool for the assessment of ischemic heart disease and its introduction into routine clinical evaluation of patients is rapidly expected. Magnetic resonance measurements allow the evaluation of reversible and irreversible myocardial ischemia, the assessment of acute myocardial infarction, as well as the recognition and detection of viable myocardium. Magnetic resonance perfusion measurements are mainly performed with T1-shortening contrast agents such as gadolinium-DTPA either by visual analysis or based on the analyses of signal intensity time curves. For the detection of myocardial ischemia the first pass kinetics of a gadolinium-DTPA bolus and for the detection of myocardial necrosis and the definition of viable myocardium steady state distribution kinetics are assessed. Quantitative analysis of myocardial perfusion can be performed but requires complex modeling due to the characteristics of gadolinium-DTPA. Thus, semi-quantitative parameters are preferred. There is accumulating evidence in the literature that magnetic resonance imaging can be used for the detection of coronary artery stenosis with high diagnostic accuracy both with semi-quantitative or visual analysis. Myocardial infarction can be reliably detected and the infarcted area determined. Non-reperfused infarcted myocardium can be differentiated from reperfused myocardium by different enhancement patterns that correlates with viability. (orig.) [German] Die Magnetresonanztomographie (MR) erlangt bei der nichtinvasiven Diagnostik der koronaren Herzerkrankung eine zunehmende Bedeutung. Mit dieser Technik koennen sowohl die globale und regionale Myokardfunktion als auch die myokardiale Perfusion exakt beurteilt werden. Bisher liegen die meisten Daten fuer die Analyse von Wandbewegungsstoerun-gen unter Belastung vor, wobei sich eine deutliche diagnostische

  9. Comparison of radionuclide and enzymatic estimate of infarct size in patients with acute myocardial infarction

    International Nuclear Information System (INIS)

    Hirsowitz, G.S.; Lakier, J.B.; Marks, D.S.; Lee, T.G.; Goldberg, A.D.; Goldstein, S.

    1983-01-01

    A comparison was made of the estimated size of the myocardial infarction occurring in 26 patients with a first infarction using creatine kinase (CK) enzyme release between radionuclide gated blood pool measurement of total and regional ventricular function and thallium-201 scintigraphic measurement of myocardial perfusion defects. Creatine kinase estimates of infarct size (enzymatic infarct size) correlated closely with the percent of abnormal contracting regions, left ventricular ejection fraction and thallium-201 estimates of percent of abnormal perfusion area (r . 0.78, 0.69 and 0.74, respectively, p less than 0.01). A close correlation also existed between percent abnormal perfusion area and percent of abnormal contracting regions (r . 0.81, p less than 0.01) and left ventricular ejection fraction (r . 0.69, p less than 0.01). Enzymatic infarct size was larger in anterior (116 +/- 37 CK-g-Eq) than inferior (52 +/- 29 CK-g-Eq) myocardial infarction (p less than 0.01) and was associated with significantly more left ventricular functional impairment as determined by left ventricular ejection fraction (33 +/- 7 versus 60 +/- 10%) (p less than 0.01) and percent abnormal perfusion area (58 +/- 14 versus 13 +/- 12) (p less than 0.01). No significant correlation was observed between enzymatic infarct size and right ventricular ejection fraction. These different methods of estimating infarct size correlated closely with each other in these patients with a first uncomplicated myocardial infarction

  10. Myocardial ischemia in Kawasaki disease

    International Nuclear Information System (INIS)

    Fukuda, Tsuyoshi

    1993-01-01

    The detection of myocardial ischemia is essential for evaluation of patients with Kawasaki disease, especially who have had coronary artery lesions. To evaluate the clinical efficacy of Tl-201 single photon emission computed tomography (SPECT) after dipyridamole infusion (maximum dose 0.70 mg/kg) for detecting myocardial ischemia, 44 patients with Kawasaki disease aged 7.7±4.8 years at the study and 10 age matched controls were observed. In the Kawasaki disease group, significant coronary artery stenosis was observed in 14, coronary aneurysm without stenosis in 18, the regression of the coronary aneurysms in 2 and without coronary lesions in 10 patients. In 24 of 44 patients, treadmill exercise stress test was also performed at the same period. Myocardial ischemic changes were observed in 11 patients, all combined with significant coronary artery stenosis. The sensitivity of SPECT for detection of overall coronary stenosis was 79%, coronary that of treadmill exercise test was only 33% (p<0.001). Furthermore, among the patients having significant coronary stenosis, the severity score was significantly elevated in patients who had electrocardiographic abnormal Q wave compared to those without abnormal Q wave (51.0±38.8 versus 20.0±12.1, p<0.05). These data suggest that the pharmacological stress scintigraphy using dipyridamole injection provides not only the accurate detection but quantitative evaluation of myocardial ischemia in these patients. This noninvasive technique may become one of the most useful index for detection and follow-up of myocardial ischemia in Kawasaki disease. (author)

  11. Low-dose myocardial blood flow imaging using 82Rb-PET (RUBILOW 2.0)

    DEFF Research Database (Denmark)

    Hoff, Camilla Molich; Tolbod, Lars Poulsen; Harms, Hans

    2017-01-01

    Aim: Relative and absolute measures of myocardial blood flow (MBF) can be derived from a 82Rb PET/CT scan using list mode data to extract static, gated and dynamic PET series. High doses of 82Rb are used to maximize image quality in especially static images. High doses require large eluate volumes...... deficit (TPD), ejection fraction (EF) and %-perfusion using the 17-segment model were calculated using commercially available software QPET (Cedars Sinai). Results: Five patients had to be excluded due to motion during STD (n=2) and LD (n=3). For the remaining patients, there was excellent correlation...

  12. Direct imaging of viable myocardium by gated SPECT in patients with ischaemic left ventricular dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Spadafora, Marco; Varrella, Paola; Spirito, Marco; Miletto, Paolo [A.O.R.N. S.G. Moscati, Department of Imaging, Avellino (Italy); Acampa, Wanda; Nappi, Carmela; Cuocolo, Alberto [University Federico II, Department of Biomorphological and Functional Sciences, Naples (Italy); SDN Foundation, Institute of Diagnostic and Nuclear Development, Naples (Italy); Mansi, Luigi [Second University, Department of Imaging, Naples (Italy); Rosato, Giuseppe [A.O.R.N. S.G. Moscati, Department of Cardiology and Heart Surgery, Avellino (Italy)

    2010-09-15

    The aim of the study was to evaluate a novel polar map of myocardial viability obtained by gated SPECT imaging to predict functional recovery after revascularization in patients with ischaemic left ventricular (LV) dysfunction. The study group comprised 17 patients (15 men, mean age 58 {+-} 9 years) with ischaemic LV dysfunction (ejection fraction {<=}40%) who underwent nitrate-enhanced gated SPECT before and 6 months after coronary revascularization. A parametric image of viable myocardium (VIA) was obtained using a semiautomated method to subtract the point-to-point motion polar map from the perfusion polar map. A parametric image of segments with functional recovery (REC) was obtained by subtracting the baseline motion polar map from the motion polar map after revascularization. Of the total 340 segments, 248 (73%) were considered viable on the basis of the VIA map. After revascularization, of 248 dysfunctional viable segments 186 (75%) showed an improvement in LV function. An increase in LV ejection fraction (from 30 {+-} 10% to 42 {+-} 11%, p < 0.01) and a decrease in end-diastolic volume (from 207 {+-} 74 ml to 174 {+-} 74 ml, p < 0.01) were observed after revascularization. Overall concordance between the VIA map and the REC map was 85%, with a k value of 0.63. Sensitivity, specificity, and positive and negative predictive values of the VIA map for predicting functional recovery were 89%, 75%, 91% and 71%, respectively. The proposed polar map of myocardial viability obtained by gated SPECT imaging accurately predicts functional recovery after coronary revascularization. Thus, a direct quantitative image of viability obtained from perfusion/function matching may be helpful for clinical decision-making in patients with ischaemic LV dysfunction. (orig.)

  13. Study progress of cardiac MRI technology in assessment of myocardial viability after myocardial infarction

    International Nuclear Information System (INIS)

    Wang Jing; Zhang Hao

    2013-01-01

    Acute myocardial infarction (AMI) is one of the most common diseases that cause disability and death around the world. Correctly and effectively assessing the myocardial viability after myocardial infarction can reduce the disabled rate and mortality rate. At present, many methods could be used to assess myocardial viability. The cardiac magnetic resonance imaging (CMR) technology has a lot of advantages compared to other methods. In this paper, we reviewed the research progress of CMR in assessment of myocardial viability after myocardial infarction, and compared CMR with other technologies. (authors)

  14. Calibration of submerged multi-sluice gates

    Directory of Open Access Journals (Sweden)

    Mohamed F. Sauida

    2014-09-01

    The main objective of this work is to study experimentally and verify empirically the different parameters affecting the discharge through submerged multiple sluice gates (i.e., the expansion ratios, gates operational management, etc.. Using multiple regression analysis of the experimental results, a general equation for discharge coefficient is developed. The results show, that the increase in the expansion ratio and the asymmetric operation of gates, give higher values for the discharge coefficient. The obtained predictions of the discharge coefficient using the developed equations are compared to the experimental data. The present developed equations showed good consistency and high accuracy.

  15. A class of quantum gate entanglers

    International Nuclear Information System (INIS)

    Heydari, Hoshang

    2010-01-01

    We construct quantum gate entanglers for different classes of multipartite states based on the definition of W and GHZ concurrence classes. First, we review the basic construction of concurrence classes based on the orthogonal complement of a positive operator valued measure (POVM) on quantum phase. Then, we construct quantum gate entanglers for different classes of multi-qubit states. In particular, we show that these operators can entangle multipartite states if they satisfy some conditions for W and GHZ classes of states. Finally, we explicitly give the W class and GHZ classes of quantum gate entanglers for four-qubit states.

  16. Resonantly driven CNOT gate for electron spins

    Science.gov (United States)

    Zajac, D. M.; Sigillito, A. J.; Russ, M.; Borjans, F.; Taylor, J. M.; Burkard, G.; Petta, J. R.

    2018-01-01

    To build a universal quantum computer—the kind that can handle any computational task you throw at it—an essential early step is to demonstrate the so-called CNOT gate, which acts on two qubits. Zajac et al. built an efficient CNOT gate by using electron spin qubits in silicon quantum dots, an implementation that is especially appealing because of its compatibility with existing semiconductor-based electronics (see the Perspective by Schreiber and Bluhm). To showcase the potential, the authors used the gate to create an entangled quantum state called the Bell state.

  17. Stay vane and wicket gate relationship study

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2005-01-19

    This report evaluates potential environmental and performance gains that can be achieved in a Kaplan turbine through non-structural modifications to stay vane and wicket gate assemblies. This summary is based primarily on data and conclusions drawn from models and studies of Lower Granite Dam. Based on this investigation, the study recommends (1) a proof of concept at Lower Granite Dam to establish predicted improvements for the existing turbine and to further refine the stay vane wicket gate designs for fish passage; and (2) consideration of the stay vane wicket gate systems in any future turbine rehabilitation studies.

  18. Gate A: changes to opening hours

    CERN Multimedia

    2015-01-01

    Due to maintenance work, the opening hours of Gate A (near Reception) will be modified between Monday, 13 and Friday, 17 April 2015.   During this period, the gate will be open to vehicles between 7 a.m. and 9.30 a.m., then between 4.30 p.m. and 7 p.m. It will be completely closed to traffic between 9.30 a.m. and 4.30 p.m. Pedestrians and cyclists may continue to use the gate. We apologise for any inconvenience and thank you for your understanding.

  19. Getting started with FortiGate

    CERN Document Server

    Fabbri, Rosato

    2013-01-01

    This book is a step-by-step tutorial that will teach you everything you need to know about the deployment and management of FortiGate, including high availability, complex routing, various kinds of VPN working, user authentication, security rules and controls on applications, and mail and Internet access.This book is intended for network administrators, security managers, and IT pros. It is a great starting point if you have to administer or configure a FortiGate unit, especially if you have no previous experience. For people that have never managed a FortiGate unit, the book helpfully walks t

  20. Gated blood pool studies with a single probe - clinical validity

    International Nuclear Information System (INIS)

    Loesel, E.; Hoffmann, G.

    1981-01-01

    The global volume alterations of the heart can be estimated non-invasively by means of the radiocardiographic function analysis developed by Hoffmann and Kleine. Since the failing heart with its functional disturbances demonstrates a pathological volume behaviour under physical exercise, it is possible to use these characteristics to differentiate between the intact heart and the failing heart by registration of the global volume alterations. The gated blood pool technique combined with the registration of the intraventricular pressure pulse by means of a Swan-Ganz flow-directed catheter enables demonstration of ventricular stroke work as a pressure-volume loop (work diagram). Its shape indicates whether the ventricle has to perform mainly pressure work or volume work. Myocardial failure is altering the basic conditions of the heart. The work diagram of the failing heart is significantly different from that of the intact human heart. It is shifted in its pressure-volume coordinates according to an increase of EDV and ESV and the rise of the filling pressure. Case demonstrations reveal the global volume behaviour of the heart under varying conditions: resting and physical exercise, drug influence on the intact and failing heart. (orig.) [de

  1. EduGATE - basic examples for educative purpose using the GATE simulation platform.

    Science.gov (United States)

    Pietrzyk, Uwe; Zakhnini, Abdelhamid; Axer, Markus; Sauerzapf, Sophie; Benoit, Didier; Gaens, Michaela

    2013-02-01

    EduGATE is a collection of basic examples to introduce students to the fundamental physical aspects of medical imaging devices. It is based on the GATE platform, which has received a wide acceptance in the field of simulating medical imaging devices including SPECT, PET, CT and also applications in radiation therapy. GATE can be configured by commands, which are, for the sake of simplicity, listed in a collection of one or more macro files to set up phantoms, multiple types of sources, detection device, and acquisition parameters. The aim of the EduGATE is to use all these helpful features of GATE to provide insights into the physics of medical imaging by means of a collection of very basic and simple GATE macros in connection with analysis programs based on ROOT, a framework for data processing. A graphical user interface to define a configuration is also included. Copyright © 2012. Published by Elsevier GmbH.

  2. Mechanosensitive gating of Kv channels.

    Directory of Open Access Journals (Sweden)

    Catherine E Morris

    Full Text Available K-selective voltage-gated channels (Kv are multi-conformation bilayer-embedded proteins whose mechanosensitive (MS Popen(V implies that at least one conformational transition requires the restructuring of the channel-bilayer interface. Unlike Morris and colleagues, who attributed MS-Kv responses to a cooperative V-dependent closed-closed expansion↔compaction transition near the open state, Mackinnon and colleagues invoke expansion during a V-independent closed↔open transition. With increasing membrane tension, they suggest, the closed↔open equilibrium constant, L, can increase >100-fold, thereby taking steady-state Popen from 0→1; "exquisite sensitivity to small…mechanical perturbations", they state, makes a Kv "as much a mechanosensitive…as…a voltage-dependent channel". Devised to explain successive gK(V curves in excised patches where tension spontaneously increased until lysis, their L-based model falters in part because of an overlooked IK feature; with recovery from slow inactivation factored in, their g(V datasets are fully explained by the earlier model (a MS V-dependent closed-closed transition, invariant L≥4. An L-based MS-Kv predicts neither known Kv time courses nor the distinctive MS responses of Kv-ILT. It predicts Kv densities (hence gating charge per V-sensor several-fold different from established values. If opening depended on elevated tension (L-based model, standard gK(V operation would be compromised by animal cells' membrane flaccidity. A MS V-dependent transition is, by contrast, unproblematic on all counts. Since these issues bear directly on recent findings that mechanically-modulated Kv channels subtly tune pain-related excitability in peripheral mechanoreceptor neurons we undertook excitability modeling (evoked action potentials. Kvs with MS V-dependent closed-closed transitions produce nuanced mechanically-modulated excitability whereas an L-based MS-Kv yields extreme, possibly excessive

  3. C-V Test Structures for Metal Gate CMOS

    NARCIS (Netherlands)

    Bankras, R.G.; Tiggelman, M.P.J.; Negara, M. Adi; Sasse, G.T.; Schmitz, Jurriaan

    2006-01-01

    Gate leakage has complicated the layout and measurement of C-V test structures. In this paper the impact of metal gate introduction to C-V test structure design is discussed. The metal gate allows for wider-gate structures and for the application of n+-p+ diffusion edges. We show, both theoretically

  4. Greening the Golden Gate National Recreation Area

    Science.gov (United States)

    The Golden Gate National Recreation Area was recognized a 2016 Federal Green Challenge Award for making significant strides to reduce its carbon footprint with the goal of becoming a carbon neutral park.

  5. Active gated imaging in driver assistance system

    Science.gov (United States)

    Grauer, Yoav

    2014-04-01

    In this paper, we shall present the active gated imaging system (AGIS) in relation to the automotive field. AGIS is based on a fast-gated camera and pulsed illuminator, synchronized in the time domain to record images of a certain range of interest. A dedicated gated CMOS imager sensor and near infra-red (NIR) pulsed laser illuminator, is presented in this paper to provide active gated technology. In recent years, we have developed these key components and learned the system parameters, which are most beneficial to nighttime (in all weather conditions) driving in terms of field of view, illumination profile, resolution, and processing power. We shall present our approach of a camera-based advanced driver assistance systems (ADAS) named BrightEye™, which makes use of the AGIS technology in the automotive field.

  6. Golden Gate and Pt. Reyes Acoustic Detections

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This dataset contains detections of acoustic tagged fish from two general locations: Golden Gate (east and west line) and Pt. Reyes. Several Vemco 69khz acoustic...

  7. Extending Double Optical Gating to the Midinfrared

    Science.gov (United States)

    Gorman, Timothy; Camper, Antoine; Agostini, Pierre; Dimauro, Louis

    2015-05-01

    In the past decade there has been great interest in creating broadband isolated attosecond pulses (IAPs). Primarily these IAPs have been generated using Ti:Sapphire 800nm short pulses, namely through spatiotemporal gating with the attosecond lighthouse technique, amplitude gating, polarization gating, and double optical gating (DOG). Here we present theoretical calculations and experimental investigations into extending DOG to using a 2 μm driving wavelength, the benefits of which include extended harmonic cutoff and longer input driving pulse durations. It is proposed that broadband IAPs with cutoffs extending up to 250 eV can be generated in Argon by using >30 fs pulses from the passively-CEP stabilized 2 μm idler out of an optical parametric amplifier combined with a collinear DOG experimental setup.

  8. Ultrathin gate valve for high vacuum operation

    Science.gov (United States)

    Ugiansky, R. J.

    1971-01-01

    Thin, compact, high-vacuum gate valve used to join two vacuum systems together demonstrates multiple operation reliability. Valve measurements and non-protruding handle make valve usable in confined areas.

  9. 2010 ARRA Lidar: Golden Gate (CA)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Golden Gate LiDAR Project is a cooperative project sponsored by the US Geological Survey (USGS) and San Francisco State University (SFSU) that has resulted in...

  10. GATING SYSTEMS FOR PRODUCTION OF HYDRODISTRIBUTORS

    Directory of Open Access Journals (Sweden)

    D. A. Volkov

    2010-01-01

    Full Text Available Gating systems of the first group of special ways of casting into shell molds, casting in lined chill mold as more effective for production of hydrodistributors were developed and studied.

  11. Smart gating membranes with in situ self-assembled responsive nanogels as functional gates

    Science.gov (United States)

    Luo, Feng; Xie, Rui; Liu, Zhuang; Ju, Xiao-Jie; Wang, Wei; Lin, Shuo; Chu, Liang-Yin

    2015-01-01

    Smart gating membranes, inspired by the gating function of ion channels across cell membranes, are artificial membranes composed of non-responsive porous membrane substrates and responsive gates in the membrane pores that are able to dramatically regulate the trans-membrane transport of substances in response to environmental stimuli. Easy fabrication, high flux, significant response and strong mechanical strength are critical for the versatility of such smart gating membranes. Here we show a novel and simple strategy for one-step fabrication of smart gating membranes with three-dimensionally interconnected networks of functional gates, by self-assembling responsive nanogels on membrane pore surfaces in situ during a vapor-induced phase separation process for membrane formation. The smart gating membranes with in situ self-assembled responsive nanogels as functional gates show large flux, significant response and excellent mechanical property simultaneously. Because of the easy fabrication method as well as the concurrent enhancement of flux, response and mechanical property, the proposed smart gating membranes will expand the scope of membrane applications, and provide ever better performances in their applications. PMID:26434387

  12. Scatter and attenuation correction changes interpretation of gated myocardial perfusion imaging

    DEFF Research Database (Denmark)

    Johansen, Allan; Grupe, Peter; Veje, Annegrete

    2004-01-01

    disease as judged from MPI. Agreement rates with regard to normal, reversible or irreversible defects between MPI-attenuation and MPI-routine for the LAD, LCX and RCA territories were 88%, 97% and 85%, respectively, without significant sex differences. In conclusion, attenuation correction caused a change...

  13. Crystalline silicotitanate gate review analysis

    International Nuclear Information System (INIS)

    Schlahta, S.N.; Carreon, R.; Gentilucci, J.A.

    1997-11-01

    Crystalline silicotitanate (CST) is an ion-exchange method for removing radioactive cesium from tank waste to allow the separation of the waste into high- and low-level fractions. The CST, originally developed Sandia National Laboratories personnel in association with Union Oil Products Corporation, has both a high affinity and selectivity for sorbing cesium-137 from highly alkaline or acidic solutions. For several years now, the U.S. Department of Energy has funded work to investigate applying CST to large-scale removal of cesium-137 from radioactive tank wastes. In January 1997, an expert panel sponsored by the Tanks Focus Area met to review the current state of the technology and to determine whether it was ready for routine use. The review also sought to identify any technical issues that must be resolved or additional CST development that must occur before full implementation by end-users. The CST Gate Review Group concluded that sufficient work has been done to close developmental work on CST and turn the remaining site-specific tasks over to the users. This report documents the review group''s findings, issues, concerns, and recommendations as well as responses from the Tanks Focus Area expert staff to specific pretreatment and immobilization issues

  14. Range gated strip proximity sensor

    Science.gov (United States)

    McEwan, T.E.

    1996-12-03

    A range gated strip proximity sensor uses one set of sensor electronics and a distributed antenna or strip which extends along the perimeter to be sensed. A micro-power RF transmitter is coupled to the first end of the strip and transmits a sequence of RF pulses on the strip to produce a sensor field along the strip. A receiver is coupled to the second end of the strip, and generates a field reference signal in response to the sequence of pulse on the line combined with received electromagnetic energy from reflections in the field. The sensor signals comprise pulses of radio frequency signals having a duration of less than 10 nanoseconds, and a pulse repetition rate on the order of 1 to 10 MegaHertz or less. The duration of the radio frequency pulses is adjusted to control the range of the sensor. An RF detector feeds a filter capacitor in response to received pulses on the strip line to produce a field reference signal representing the average amplitude of the received pulses. When a received pulse is mixed with a received echo, the mixing causes a fluctuation in the amplitude of the field reference signal, providing a range-limited Doppler type signature of a field disturbance. 6 figs.

  15. Boolean gates on actin filaments

    Science.gov (United States)

    Siccardi, Stefano; Tuszynski, Jack A.; Adamatzky, Andrew

    2016-01-01

    Actin is a globular protein which forms long polar filaments in the eukaryotic cytoskeleton. Actin networks play a key role in cell mechanics and cell motility. They have also been implicated in information transmission and processing, memory and learning in neuronal cells. The actin filaments have been shown to support propagation of voltage pulses. Here we apply a coupled nonlinear transmission line model of actin filaments to study interactions between voltage pulses. To represent digital information we assign a logical TRUTH value to the presence of a voltage pulse in a given location of the actin filament, and FALSE to the pulse's absence, so that information flows along the filament with pulse transmission. When two pulses, representing Boolean values of input variables, interact, then they can facilitate or inhibit further propagation of each other. We explore this phenomenon to construct Boolean logical gates and a one-bit half-adder with interacting voltage pulses. We discuss implications of these findings on cellular process and technological applications.

  16. Induced Cavities for Photonic Quantum Gates

    Science.gov (United States)

    Lahad, Ohr; Firstenberg, Ofer

    2017-09-01

    Effective cavities can be optically induced in atomic media and employed to strengthen optical nonlinearities. Here we study the integration of induced cavities with a photonic quantum gate based on Rydberg blockade. Accounting for loss in the atomic medium, we calculate the corresponding finesse and gate infidelity. Our analysis shows that the conventional limits imposed by the blockade optical depth are mitigated by the induced cavity in long media, thus establishing the total optical depth of the medium as a complementary resource.

  17. Entanglement and Quantum Logical Gates. Part I.

    Science.gov (United States)

    Freytes, H.; Giuntini, R.; Leporini, R.; Sergioli, G.

    2015-12-01

    Is it possible to give a logical characterization of entanglement and of entanglement-measures in terms of the probabilistic behavior of some gates? This question admits different (positive or negative) answers in the case of different systems of gates and in the case of different classes of density operators. In the first part of this article we investigate possible relations between entanglement-measures and the probabilistic behavior of quantum computational conjunctions.

  18. Dual-gated volumetric modulated arc therapy

    International Nuclear Information System (INIS)

    Fahimian, Benjamin; Wu, Junqing; Wu, Huanmei; Geneser, Sarah; Xing, Lei

    2014-01-01

    Gated Volumetric Modulated Arc Therapy (VMAT) is an emerging radiation therapy modality for treatment of tumors affected by respiratory motion. However, gating significantly prolongs the treatment time, as delivery is only activated during a single respiratory phase. To enhance the efficiency of gated VMAT delivery, a novel dual-gated VMAT (DG-VMAT) technique, in which delivery is executed at both exhale and inhale phases in a given arc rotation, is developed and experimentally evaluated. Arc delivery at two phases is realized by sequentially interleaving control points consisting of MUs, MLC sequences, and angles of VMAT plans generated at the exhale and inhale phases. Dual-gated delivery is initiated when a respiration gating signal enters the exhale window; when the exhale delivery concludes, the beam turns off and the gantry rolls back to the starting position for the inhale window. The process is then repeated until both inhale and exhale arcs are fully delivered. DG-VMAT plan delivery accuracy was assessed using a pinpoint chamber and diode array phantom undergoing programmed motion. DG-VMAT delivery was experimentally implemented through custom XML scripting in Varian’s TrueBeam™ STx Developer Mode. Relative to single gated delivery at exhale, the treatment time was improved by 95.5% for a sinusoidal breathing pattern. The pinpoint chamber dose measurement agreed with the calculated dose within 0.7%. For the DG-VMAT delivery, 97.5% of the diode array measurements passed the 3%/3 mm gamma criterion. The feasibility of DG-VMAT delivery scheme has been experimentally demonstrated for the first time. By leveraging the stability and natural pauses that occur at end-inspiration and end-exhalation, DG-VMAT provides a practical method for enhancing gated delivery efficiency by up to a factor of two

  19. Myocardial infarction and stem cells

    Directory of Open Access Journals (Sweden)

    K Ananda Krishna

    2011-01-01

    Full Text Available Permanent loss of cardiomyocytes and scar tissue formation after myocardial infarction (MI results in an irreversible damage to the cardiac function. Cardiac repair (replacement, restoration, and regeneration is, therefore, essential to restore function of the heart following MI. Existing therapies lower early mortality rates, prevent additional damage to the heart muscle, and reduce the risk of further heart attacks. However, there is need for treatment to improve the infarcted area by replacing the damaged cells after MI. Thus, the cardiac tissue regeneration with the application of stem cells may be an effective therapeutic option. Recently, interest is more inclined toward myocardial regeneration with the application of stem cells. However, the potential benefits and the ability to improve cardiac function with the stem cell-based therapy need to be further addressed. In this review, we focus on the clinical applications of stem cells in the cardiac repair.

  20. [Silent myocardial ischemia in diabetics].

    Science.gov (United States)

    Zednícek, L; Hrubá, J

    1989-11-01

    The present communication deals with knowledge gained at detecting episodes of silent myocardial ischaemia in a group of diabetics with a positive load ECG test. With the recent advance of new examination methods it becomes evident that the asymptomatic transitional defects of perfusion or myocardial function in patients with ischaemic heart disease are apparently the most frequent ischaemic accidents which the patient experiences during his or her usual daily activity. They are not caused by increased demands on oxygen supply by the myocardium, rather it is the case of decreased oxygen supply due to dynamic changes in arterial blood supply of the myocardium during transient arterial vasoconstriction. These accidents are markedly more frequent in diabetic patients in whom an earlier and more severe development of ischaemic heart disease occurs. Associated are also specific changes in autonomous nerve fibres conducting pain, which shift a number of ischaemic episodes to the asymptomatic form.

  1. Evaluation of myocardial perfusion and ventricular shape in hypertrophic cardiomyopathy using [sup 99m]Tc-tetrofosmin scintigraphy; Comparison with [sup 201]Tl myocardial scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Ohtsuki, Katsuichi; Taniguchi, Yoko (Kyoto Prefectural Univ. of Medicine (Japan)); Sugihara, Hiroki (and others)

    1994-04-01

    Hypertrophic cardiomyopathy (HCM) is known to have the impairment of myocardial perfusion as well as irregularly hypertrophic myocardium. To evaluate myocardial perfusion and ventricular shape in HCM, [sup 99m]Tc-Tetrofosmin scintigraphy was performed after exercise (Ex) and at resting state (Re) in 10 patients with HCM and was compared with early image (Ea) and delayed image (De) of [sup 201]Tl scintigraphy performed after exercise. SPECT images of both [sup 99m]Tc-Tetrofosmin and [sup 201]Tl scintigraphy were analyzed with five scaled visual scores set in 18 segments. The complete concordance ratio between [sup 99m]Tc-Tetrofosmin (Ex and Re) and [sup 201]Tl(Ea and De) images in segmental analysis was 75%. Image quality of [sup 99m]Tc-Tetrofosmin was seemed to be superior to that of [sup 201]Tl scintigraphy. In 9 patients with HCM, [sup 99m]Tc-Tetrofosmin scintigraphy was performed under the ECG gating and the thickness of septal and free wall was measured. Good correlation was observed with the data by ultrasound cardiography (r=0.79, p<0.002 in wall thickness, r=0.84, p<0.01 in the ratio of septal wall thickness to free wall thickness). Left ventricular shape (ventricular long axis) was closely resemble to that of left ventriculography by contrast medium. In conclusion, [sup 99m]Tc-Tetrofosmin scintigraphy is useful for the evaluation of myocardial morphology as well as perfusion abnormality. (author).

  2. Static myocardial scintigraphy in pediatrics

    International Nuclear Information System (INIS)

    Gilday, D.L.

    1981-01-01

    Examples are given for the applications of 201 Tl myocardial scintiscanning in prediatries. In this case, a very careful clinical assessment should be made at first and, whenever possible, the non-invasive modalities such as ultrasonography should be preferred. The transient myorcardial ischemia of the newborn is an example which demonstrates best the role that thallium can play in eliminating cardiac catheterization, a much greater radiation-producing and hazardous procedure. (MG)

  3. Cognitive mechanisms associated with auditory sensory gating.

    Science.gov (United States)

    Jones, L A; Hills, P J; Dick, K M; Jones, S P; Bright, P

    2016-02-01

    Sensory gating is a neurophysiological measure of inhibition that is characterised by a reduction in the P50 event-related potential to a repeated identical stimulus. The objective of this work was to determine the cognitive mechanisms that relate to the neurological phenomenon of auditory sensory gating. Sixty participants underwent a battery of 10 cognitive tasks, including qualitatively different measures of attentional inhibition, working memory, and fluid intelligence. Participants additionally completed a paired-stimulus paradigm as a measure of auditory sensory gating. A correlational analysis revealed that several tasks correlated significantly with sensory gating. However once fluid intelligence and working memory were accounted for, only a measure of latent inhibition and accuracy scores on the continuous performance task showed significant sensitivity to sensory gating. We conclude that sensory gating reflects the identification of goal-irrelevant information at the encoding (input) stage and the subsequent ability to selectively attend to goal-relevant information based on that previous identification. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  4. Sensory gating deficits in parents of schizophrenics

    Energy Technology Data Exchange (ETDEWEB)

    Waldo, M.; Madison, A.; Freedman, R. [Univ. of Colorado Health Sciences Center, Denver, CO (United States)] [and others

    1995-12-18

    Although schizophrenia clusters in families, it is not inherited in Mendelian fashion. This suggests that there may be alternative phenotypic expressions of genes that convey risk for schizophrenia, such as more elementary physiological or biochemical defects. One proposed phenotype is impaired inhibitory gating of the auditory evoked potential to repeated stimuli. Normally, the amplitude of the P50 response to the second stimulus is significantly less than the response to the first, but this gating of response is generally impaired in schizophrenia. Clinically unaffected individuals within a pedigree who have both an ancestral and descendant history of schizophrenia may be useful for studying whether this physiological defect is a possible alternative phenotype. We have studied inhibitory gating of the auditory P50 response to pairs of auditory stimuli in 17 nuclear families. In 11, there was one parent who had another relative with a chronic psychotic illness, in addition to the schizophrenic proband. AR of the parents with family histories of schizophrenia had gating of the P50 response similar to their schizophrenia offspring, whereas only 7% of the parents without family history had gating of the P50 response in the abnormal range. These results support loss of gating of the auditory P50 wave as an inherited deficit related to schizophrenia and suggest that studies of parents may help elucidate the neurobiological expression of genes that convey risk for schizophrenia. 36 refs., 2 figs., 2 tabs.

  5. VKCDB: Voltage-gated potassium channel database

    Directory of Open Access Journals (Sweden)

    Gallin Warren J

    2004-01-01

    Full Text Available Abstract Background The family of voltage-gated potassium channels comprises a functionally diverse group of membrane proteins. They help maintain and regulate the potassium ion-based component of the membrane potential and are thus central to many critical physiological processes. VKCDB (Voltage-gated potassium [K] Channel DataBase is a database of structural and functional data on these channels. It is designed as a resource for research on the molecular basis of voltage-gated potassium channel function. Description Voltage-gated potassium channel sequences were identified by using BLASTP to search GENBANK and SWISSPROT. Annotations for all voltage-gated potassium channels were selectively parsed and integrated into VKCDB. Electrophysiological and pharmacological data for the channels were collected from published journal articles. Transmembrane domain predictions by TMHMM and PHD are included for each VKCDB entry. Multiple sequence alignments of conserved domains of channels of the four Kv families and the KCNQ family are also included. Currently VKCDB contains 346 channel entries. It can be browsed and searched using a set of functionally relevant categories. Protein sequences can also be searched using a local BLAST engine. Conclusions VKCDB is a resource for comparative studies of voltage-gated potassium channels. The methods used to construct VKCDB are general; they can be used to create specialized databases for other protein families. VKCDB is accessible at http://vkcdb.biology.ualberta.ca.

  6. Mortality rate in type 2 myocardial infarction

    DEFF Research Database (Denmark)

    Saaby, Lotte; Poulsen, Tina Svenstrup; Diederichsen, Axel Cosmus Pyndt

    2014-01-01

    BACKGROUND: The classification of myocardial infarction into 5 types was introduced in 2007. The prognostic impact of this universal definition, with particular focus on type 2 myocardial infarction, has not been studied prospectively in unselected hospital patients. METHODS: During a 1-year period......, all hospitalized patients having cardiac troponin I measured were considered. The diagnosis of a myocardial infarction was according to the universal definition, and specified criteria were used in the classification of type 2 myocardial infarction. Follow-up was at least 1 year, with mortality...... as the end point. RESULTS: A total of 3762 consecutive patients were studied, of whom 488 (13%) had a myocardial infarction. In 119 patients a type 2 myocardial infarction was diagnosed. After a median of 2.1 years (interquartile range, 1.6-2.5 years), 150 patients had died, with a mortality rate of 49% (58...

  7. Novel adjunctive treatments of myocardial infarction

    DEFF Research Database (Denmark)

    Schmidt, Michael Rahbek; Pryds, Kasper; Bøtker, Hans Erik

    2014-01-01

    Myocardial infarction is a major cause of death and disability worldwide and myocardial infarct size is a major determinant of prognosis. Early and successful restoration of myocardial reperfusion following an ischemic event is the most effective strategy to reduce final infarct size and improve...... by endovascular infusion of cold saline all reduce infarct size and may confer clinical benefit for patients admitted with acute myocardial infarcts. Equally promising, three follow-up studies of the effect of remote ischemic conditioning (RIC) show clinical prognostic benefit in patients undergoing coronary...... clinical outcome, but reperfusion may induce further myocardial damage itself. Development of adjunctive therapies to limit myocardial reperfusion injury beyond opening of the coronary artery gains increasing attention. A vast number of experimental studies have shown cardioprotective effects of ischemic...

  8. Assessment of myocardial viability using PET

    International Nuclear Information System (INIS)

    Yoon, Seok Nam

    2005-01-01

    The potential for recovery of left ventricular dysfunction after myocardial revascularization represents a practical clinical definition for myocardial viability. The evaluation of viable myocardium in patients with severe global left ventricular dysfunction due to coronary artery disease and with regional dysfunction after acute myocardial infarction is an important issue whether left ventricular dysfunction may be reversible or irreversible after therapy. If the dysfunction is due to stunning or hibernation, functional improvement is observed. But stunned myocardium may recover of dysfunction with no revascularization. Hibernation is chronic process due to chronic reduction in the resting myocardial blood flow. There are two types of myocardial hibernation; 'functional hibernation' with preserved contractile reserve and 'structural hibernation' without contractile reserve in segments with preserved glucose metabolism. This review focus on the application of F-18 FDG and other radionuclides to evaluate myocardial viability. In addition the factors influencing predictive value of FDG imaging for evaluating viability and the different criteria for viability are also reviewed

  9. Cardiac MRI for myocardial ischemia.

    LENUS (Irish Health Repository)

    Daly, Caroline

    2013-01-01

    Proper assessment of the physiologic impact of coronary artery stenosis on the LV myocardium can affect patient prognosis and treatment decisions. Cardiac magnetic resonance imaging (CMR) assesses myocardial perfusion by imaging the myocardium during a first-pass transit of an intravenous gadolinium bolus, with spatial and temporal resolution substantially higher than nuclear myocardial perfusion imaging. Coupled with late gadolinium enhancement (LGE) imaging for infarction during the same imaging session, CMR with vasodilating stress perfusion imaging can qualitatively and quantitatively assess the myocardial extent of hypoperfusion from coronary stenosis independent of infarcted myocardium. This approach has been validated experimentally, and multiple clinical trials have established its diagnostic robustness when compared to stress single-photon emission computed tomography. In specialized centers, dobutamine stress CMR has been shown to have incremental diagnostic value above stress echocardiography due to its high imaging quality and ability to image the heart with no restriction of imaging window. This paper reviews the technical aspects, diagnostic utility, prognostic values, challenges to clinical adaptation, and future developments of stress CMR imaging.

  10. Leukocytosis: a risk factor for myocardial infarction

    OpenAIRE

    Kotla, Suman

    2012-01-01

    Suman K KotlaDepartment of Internal Medicine, Memorial Medical Center, Johnstown, PA, USAAbstract: Myocardial infarction commonly results from atherosclerotic lesions in the coronary arteries. Approximately 5% of patients with acute myocardial infarction do not have atherosclerotic disease. In this case report, we present an unusual leukostatic complication in a patient with acute myeloblastic leukemia and extreme hyperleukocytosis who presented with an acute myocardial infarction that resolv...

  11. Different Causes of Death in Patients with Myocardial Infarction Type 1, Type 2 and Myocardial Injury

    DEFF Research Database (Denmark)

    Lambrecht, S; Sarkisian, Laura; Saaby, Lotte

    2017-01-01

    BACKGROUND: Data outlining the mortality and the causes of death in patients with type 1 myocardial infarction, type 2 myocardial infarction and those with myocardial injury are limited. METHODS: During a 1-year period from January 2010 to January 2011 all hospitalized patients, who had cardiac t...

  12. Increases in myeloperoxidase levels after exercise in myocardial perfusion scintigraphy are not induced by myocardial ischemia

    NARCIS (Netherlands)

    van der Zee, P. M.; Meuwese, M. C.; Verberne, H. J.; de Ruijter, M.; van Straalen, J. P.; Fischer, J. C.; Sturk, A.; van Eck-Smit, B. L. F.; Stroes, E. S. G.; de Winter, R. J.

    2008-01-01

    Background: Increased systemic levels of myeloperoxidase (MPO) have been reported in patients with acute myocardial ischemia. We studied the association between exercise-induced myocardial ischemia measured by myocardial perfusion scintigraphy (MPS) and the magnitude and time course of changes in

  13. Electrocardiographic gating of list mode data with a positron emission tomography system that utilizes wobbling motion to achieve uniform sampling

    International Nuclear Information System (INIS)

    Gaeta, J.M.; Yerian, K.A.; Mullani, N.A.

    1986-01-01

    An interactive software package has been developed for gating of list mode data acquired with PET. The package supports: histogram displays (ie. for determining an acceptable beat interval length window), automatic rejection of beats outside the window, forward or backward gating capabilities, capability of specifying the position of the gating interval, and of the time interval within the list mode study to be reformatted. The interaction of PET wobble motion frequency and heart beat frequency may result in image non-uniformities (ringing artifacts), due to incomplete wobble sampling. Therefore, the reconstruction software incorporates a very simple scheme for correcting for the amount of time spent at each wobble position and allowing for the decay of short lived isotopes such as Rubidium-82 (Rb-82). Rb-82 myocardial uptake images free of non-uniformity artifacts and quantitatively accurate have been reconstructed for 10 different dog studies, and 8 patient studies. Multi-slice frames at discrete portions of the heart cycle (i.e. End Diastole) and multi-gated sequences for cine display have been produced

  14. Clinical usefulness of Tc-99m hexakis 2-methoxybutyl isonitrile gated SPECT in patients with dilated cardiomyopathy: retrospective analysis

    International Nuclear Information System (INIS)

    Khan, Z.R.; Khan, A.Z.

    2010-01-01

    Background: In Dilated cardiomyopathy the heart is enlarged and ventricles are dilated. Gated myocardial perfusion single photon emission computed tomography is considered state of the art for myocardial perfusion imaging. A retrospective analysis was conducted to evaluate patients with dilated cardiomyopathy with Tc-99m sestamibi gated myocardial perfusion single photon emission computed tomography to evaluate its clinical utility. Methods: A 10 year retrospective medical record review was done from 1991 to 2001 at Wake Forest University, North Carolina, USA. Eligibility criteria included a diagnosis of dilated cardiomyopathy and availability of coronary angiography and Tc-99m sestamibi cardiac imaging results. 26 cases were selected for the final review and inclusion in the study. The study was done with standard protocols for cardiac sestamibi imaging. Results: A total of 26 cases were included in the final analysis. Cases were divided into two main groups. Group-A included 16 patients with no correlation between Tc-99m sestamibi and cardiac catheterisation reports. Group-B included 10 patients with good correlation between the above tests. There were no significant differences between the left ventricular ejection fraction, angina history, sex distribution and diabetic status between the two groups. We applied Wilcoxon Signed Rank Test and z-test to quantify the difference between the two groups. Data was tabulated and z-test was performed. The calculated p value was <0.0001. This is significantly less than the tabulated p-value at 5% level of significance, i.e., 1.96. Significant differences exist between Group-A and Group-B. Conclusion: Tc-99m sestamibi is an excellent agent for investigating myocardial perfusion in dilated cardiomyopathy. The reversible and fixed perfusion defects (small to medium sized) seen in dilated cardiomyopathy after performance of Tc-99m sestamibi gated single photon emission computed tomography imaging may not be due to coronary

  15. Clinical usefulness of Tc-99m hexakis 2-methoxyisobutyl isonitrile gated spect in patients with dilated cardiomyopathy: retrospective analysis.

    Science.gov (United States)

    Khan, Zahid Rahman; Watson, Nat E; Khan, Afshan Zahid

    2010-01-01

    In Dilated cardiomyopathy the heart is enlarged and ventricles are dilated. Gated myocardial perfusion single photon emission computed tomography is considered state of the art for myocardial perfusion imaging. A retrospective analysis was conducted to evaluate patients with dilated cardiomyopathy with Tc-99m sestamibi gated myocardial perfusion single photon emission computed tomography to evaluate its clinical utility. A 10 year retrospective medical record review was done from 1991 to 2001 at Wake Forest University, North Carolina, USA. Eligibility criteria included a diagnosis of dilated cardiomyopathy and availability of coronary angiography and Tc-99m sestamibi cardiac imaging results. 26 cases were selected for the final review and inclusion in the study. The study was done with standard protocols for cardiac sestamibi imaging. A total of 26 cases were included in the final analysis. Cases were divided into two main groups. Group-A included 16 patients with no correlation between Tc-99m sestamibi and cardiac catheterisation reports. Group-B included 10 patients with good correlation between the above tests. There were no significant differences between the left ventricular ejection fraction, angina history, sex distribution and diabetic status between the two groups. We applied Wilcoxon Signed Rank Test and z-test to quantify the difference between the two groups. Data was tabulated and z-test was performed. The calculated p-value was <0.0001. This is significantly less than the tabulated p-value at 5% level of significance, i.e., 1.96. Significant differences exist between Group-A and Group-B. Tc-99m sestamibi is an excellent agent for investigating myocardial perfusion in dilated cardiomyopathy. The reversible and fixed perfusion defects (small to medium sized) seen in dilated cardiomyopathy after performance of Tc-99m sestamibi gated single photon emission computed tomography imaging may not be due to coronary artery disease. Tc-99m sestamibi single

  16. Serial myocardial perfusion imaging: defining a significant change and targeting management decisions.

    Science.gov (United States)

    Iskandrian, Ami E; Hage, Fadi G; Shaw, Leslee J; Mahmarian, John J; Berman, Daniel S

    2014-01-01

    Myocardial perfusion imaging (MPI) with gated single-photon emission tomography provides important information on the extent and severity of myocardial perfusion abnormalities, including myocardial ischemia. The availability of software for automated quantitative assessment of myocardial perfusion in an objective and more reproducible manner than visual assessment has allowed MPI to be particularly effective in serial evaluation. Serial testing using MPI is widely used in guiding patient care despite the lack of well-defined appropriateness use criteria. This should not be surprising because ischemic heart disease is a life-long malady subject to dynamic changes throughout its natural course and particularly following man-made interventions that may improve or worsen the disease process, such as medical therapy and coronary revascularization. Serial MPI has filled an important clinical gap by providing crucial information for managing patients with changes in clinical presentations or in anticipation of such changes in patients with stable symptoms. In the research arena, serial MPI has been widely applied in randomized controlled trials to study the impact of various medical and interventional therapies on myocardial perfusion, as well as the relative merits of new imaging procedures (hardware and/or software), radiotracers, and stressor agents. Serial testing, however, unlike initial or 1-time testing, has more stringent requirements and is subject to variability because of technical, procedural, interpretational, and biological factors. The intrinsic variability of MPI becomes important in interpreting serial tests in order to define a true change in a given patient and to guide clinical decision making. The purpose of this first comprehensive review on this subject is to illustrate where serial MPI may be useful clinically and in research studies, and to highlight strategies for addressing the various issues that are unique to serial testing in order to derive

  17. [Myocardial microcirculation in humans--new approaches using MRI].

    Science.gov (United States)

    Wacker, Christian M; Bauer, Wolfgang R

    2003-03-01

    of this autoregulatory response so far. Our laboratory recently developed different techniques for the assessment of myocardial perfusion, regional myocardial blood volume, and capillary recruitment. These techniques are based on theoretical and physiologic considerations and work mainly without CA. In this article, feasibility and reproducibility of these approaches are shown in volunteers and patients. MR exams were performed on a 1.5-T whole body scanner (SIEMENS Vision) and a 2-T system (BRUKER Tomikon). Stress examinations were done repeatedly under pharmacologically induced stress (dipyridamole or adenosine, infusion rate: 0.56 mg/kg body weight over 4 min via an antecubital vein). Heart rate and blood pressure were continuously monitored during stress exams. T1 Spin labeling used in this work is based on T1 measurements after global and slice-selective spin preparation using a fast ECG-gated saturation recovery FLASH sequence. Due to the inflow of unsaturated proton spins, T1 in tissue is shortened after slice-selective preparation case compared to global saturation. We showed that, assuming a two compartment model with fast proton exchange between the compartments, the absolute perfusion P (in [ml/g/min]) can be calculated as P = lambda/T1(blood) ([T1(global)/T1(selective)] - 1), where the blood tissue partition coefficient lambda represents the quotient of water content of capillary blood and perfused tissue, which is approximately 0.9 ml/g in myocardial tissue. T1(blood) is the longitudinal relaxation time T1 of the arterial blood, measured in the left ventricle (LV). T1(global) and T1(selective) are the myocardial T1 calculated after the respective spin preparation. Perfusion reserve is evaluated as the quotient of perfusion under adenosine-induced stress and perfusion at rest. In volunteers quantitative perfusion was determined as 2.5 +/- 0.7 ml/g/min (rest), perfusion reserve was about 2.0. Absolute perfusion decreased to 1.6 +/- 0.6 ml/g/min under

  18. Gallium arsenide processing for gate array logic

    Science.gov (United States)

    Cole, Eric D.

    1989-01-01

    The development of a reliable and reproducible GaAs process was initiated for applications in gate array logic. Gallium Arsenide is an extremely important material for high speed electronic applications in both digital and analog circuits since its electron mobility is 3 to 5 times that of silicon, this allows for faster switching times for devices fabricated with it. Unfortunately GaAs is an extremely difficult material to process with respect to silicon and since it includes the arsenic component GaAs can be quite dangerous (toxic) especially during some heating steps. The first stage of the research was directed at developing a simple process to produce GaAs MESFETs. The MESFET (MEtal Semiconductor Field Effect Transistor) is the most useful, practical and simple active device which can be fabricated in GaAs. It utilizes an ohmic source and drain contact separated by a Schottky gate. The gate width is typically a few microns. Several process steps were required to produce a good working device including ion implantation, photolithography, thermal annealing, and metal deposition. A process was designed to reduce the total number of steps to a minimum so as to reduce possible errors. The first run produced no good devices. The problem occurred during an aluminum etch step while defining the gate contacts. It was found that the chemical etchant attacked the GaAs causing trenching and subsequent severing of the active gate region from the rest of the device. Thus all devices appeared as open circuits. This problem is being corrected and since it was the last step in the process correction should be successful. The second planned stage involves the circuit assembly of the discrete MESFETs into logic gates for test and analysis. Finally the third stage is to incorporate the designed process with the tested circuit in a layout that would produce the gate array as a GaAs integrated circuit.

  19. Normal myocardial perfusion scan portends a benign prognosis independent from the pretest probability of coronary artery disease. Sub-analysis of the J-ACCESS study

    International Nuclear Information System (INIS)

    Imamura, Yosihiro; Fukuyama, Takaya; Nishimura, Sigeyuki; Nishimura, Tsunehiko

    2009-01-01

    We assessed the usefulness of gated stress/rest 99mTc-tetrofosmin myocardial perfusion single photon emission computed tomography (SPECT) to predict ischemic cardiac events in Japanese patients with various estimated pretest probabilities of coronary artery disease (CAD). Of the 4031 consecutively registered patients for a J-ACCESS (Japanese Assessment of Cardiac Events and Survival Study by Quantitative Gated SPECT) study, 1904 patients without prior cardiac events were selected. Gated stress/rest myocardial perfusion SPECT was performed and segmental perfusion scores and quantitative gated SPECT results were derived. The pretest probability for having CAD was estimated using the American College of Cardiology/American Heart Association/American College of Physicians- American Society of Internal Medicine guideline data for the management of patients with chronic stable angina, which includes age, gender, and type of chest discomfort. The patients were followed up for three years. During the three-year follow-up period, 96 developed ischemic cardiac events: 17 cardiac deaths, 8 nonfatal myocardial infarction, and 71 clinically driven revascularization. The summed stress score (SSS) was the most powerful independent predictor of all ischemic cardiac events (hazard ratio 1.077, confidence interval (CI) 1.045-1.110). Abnormal SSS (>3) was associated with a significantly higher cardiac event rate in patients with an intermediate to high pretest probability of CAD. Normal SSS (≤3) was associated with a low event rate in patients with any pretest probability of CAD. Myocardial perfusion SPECT is useful for further risk-stratification of patients with suspected CAD. The abnormal scan result (SSS>3) is discriminative for subsequent cardiac events only in the groups with an intermediate to high pretest probability of CAD. The salient result is that normal scan results portend a benign prognosis independent from the pretest probability of CAD. (author)

  20. Clinical value of delayed thallium-201 myocardial imaging in suspected acute myocardial infarction.

    Science.gov (United States)

    McKillop, J H; Turner, J G; Gray, H W; Bessent, R G; Greig, W R

    1978-01-01

    Fifty patients with acute chest pain had thallium-201 myocardial imaging performed three to six days after emergency admission to hospital. The image was abnormal in 20 out of 22 patients with acute transmural myocardial infarcts but in only 1 of 5 with acute subendocardial infarcts. Indistinguishable scan abnormalities caused by old infarcts were seen in 7 patients, and caused by myocardial ischaemia in 1 patient. A single thallium-201 myocardial scan some days after the onset of symptoms appears to be of little value in the clinical assessment of patients with suspected acute myocardial infarction. Images PMID:687488

  1. Screening for silent myocardial ischemia caseof diabetics : interest of myocardial perfusion scintigraphy

    International Nuclear Information System (INIS)

    Bahri, Haifa

    2007-01-01

    Silent myocardial ischemia is a major cause of morbidity and mortality in diabetic patients. Its diagnosis by noninvasive means such as myocardial SPECT would improve the management of these patients. The purpose of this study is to assess the frequency of silent myocardial ischemia in asymptomatic diabetics and their evolution. As a result, the myocardial SPECT is a reliable tool for screening for silent myocardial ischemia in diabetic patients. Its prognostic value allows to stratify the cardiac risk and guide therapeutic management. Its integration into a screening strategy in Tunisia seems limited by its low availability and cost. The latter could be reduced by better patient selection.

  2. Thrombolysis significantly reduces transient myocardial ischaemia following first acute myocardial infarction

    DEFF Research Database (Denmark)

    Mickley, H; Pless, P; Nielsen, J R

    1992-01-01

    In order to investigate whether thrombolysis affects residual myocardial ischaemia, we prospectively performed a predischarge maximal exercise test and early out-of-hospital ambulatory ST segment monitoring in 123 consecutive men surviving a first acute myocardial infarction (AMI). Seventy...... less than 0.02). Thrombolysis resulted in a non-significant reduction in exercise-induced ST segment depression: prevalence 43% vs 62% in controls. However, during ambulatory monitoring the duration of transient myocardial ischaemia was significantly reduced in thrombolysed patients: 322 min vs 1144...... myocardial ischaemia. This may explain the improvement in myocardial function during physical activities, which was also observed in this study....

  3. Palladium gates for reproducible quantum dots in silicon.

    Science.gov (United States)

    Brauns, Matthias; Amitonov, Sergey V; Spruijtenburg, Paul-Christiaan; Zwanenburg, Floris A

    2018-04-09

    We replace the established aluminium gates for the formation of quantum dots in silicon with gates made from palladium. We study the morphology of both aluminium and palladium gates with transmission electron microscopy. The native aluminium oxide is found to be formed all around the aluminium gates, which could lead to the formation of unintentional dots. Therefore, we report on a novel fabrication route that replaces aluminium and its native oxide by palladium with atomic-layer-deposition-grown aluminium oxide. Using this approach, we show the formation of low-disorder gate-defined quantum dots, which are reproducibly fabricated. Furthermore, palladium enables us to further shrink the gate design, allowing us to perform electron transport measurements in the few-electron regime in devices comprising only two gate layers, a major technological advancement. It remains to be seen, whether the introduction of palladium gates can improve the excellent results on electron and nuclear spin qubits defined with an aluminium gate stack.

  4. Cardiac-gated parametric images from82Rb PET from dynamic frames and direct 4D reconstruction.

    Science.gov (United States)

    Germino, Mary; Carson, Richard E

    2018-02-01

    Cardiac perfusion PET data can be reconstructed as a dynamic sequence and kinetic modeling performed to quantify myocardial blood flow, or reconstructed as static gated images to quantify function. Parametric images from dynamic PET are conventionally not gated, to allow use of all events with lower noise. An alternative method for dynamic PET is to incorporate the kinetic model into the reconstruction algorithm itself, bypassing the generation of a time series of emission images and directly producing parametric images. So-called "direct reconstruction" can produce parametric images with lower noise than the conventional method because the noise distribution is more easily modeled in projection space than in image space. In this work, we develop direct reconstruction of cardiac-gated parametric images for 82 Rb PET with an extension of the Parametric Motion compensation OSEM List mode Algorithm for Resolution-recovery reconstruction for the one tissue model (PMOLAR-1T). PMOLAR-1T was extended to accommodate model terms to account for spillover from the left and right ventricles into the myocardium. The algorithm was evaluated on a 4D simulated 82 Rb dataset, including a perfusion defect, as well as a human 82 Rb list mode acquisition. The simulated list mode was subsampled into replicates, each with counts comparable to one gate of a gated acquisition. Parametric images were produced by the indirect (separate reconstructions and modeling) and direct methods for each of eight low-count and eight normal-count replicates of the simulated data, and each of eight cardiac gates for the human data. For the direct method, two initialization schemes were tested: uniform initialization, and initialization with the filtered iteration 1 result of the indirect method. For the human dataset, event-by-event respiratory motion compensation was included. The indirect and direct methods were compared for the simulated dataset in terms of bias and coefficient of variation as a

  5. Creatine Depletion and Altered Fatty Acid Metabolism in Diseased Human Hearts: Clinical Investigation Using 1H Magnetic Resonance Spectroscopy and 123I BMIPP Myocardial Scintigraphy

    International Nuclear Information System (INIS)

    Nakae, I.; Mitsunami, K.; Matsuo, S.; Horie, M.

    2007-01-01

    Background: In the heart, the creatine kinase system plays an important role in energy reserves, and myocardial energy production essentially depends upon fatty acid metabolism. Purpose: To examine myocardial creatine (CR) concentration and altered cardiac fatty acid metabolism in various forms of heart disease. Material and Methods: Myocardial CR concentration of the septum was measured by gated 1 H magnetic resonance spectroscopy (MRS), applying a point-resolved spectroscopy (PRESS) sequence in 34 patients with heart disease. Of these patients, 14 underwent 123 I BMIPP (radioactive fatty acid analogue) myocardial scintigraphy to evaluate myocardial fatty acid metabolism. Cardiac 123 I BMIPP uptake was calculated as the heart-to-mediastinum count ratio. Results: Myocardial CR concentration correlated positively with the left ventricular ejection fraction (LVEF) by echocardiography (R = 0.61, P 123 I BMIPP uptake also correlated positively with LVEF (initial image, R 0.60, P 123 I BMIPP uptake (initial image, R = 0.77, P<0.01; delayed image, R = 0.82, P<0.001; n = 14). Conclusion: Our study suggests an association between CR depletion and impaired fatty acid metabolism in various forms of heart diseases

  6. Instantons in Self-Organizing Logic Gates

    Science.gov (United States)

    Bearden, Sean R. B.; Manukian, Haik; Traversa, Fabio L.; Di Ventra, Massimiliano

    2018-03-01

    Self-organizing logic is a recently suggested framework that allows the solution of Boolean truth tables "in reverse"; i.e., it is able to satisfy the logical proposition of gates regardless to which terminal(s) the truth value is assigned ("terminal-agnostic logic"). It can be realized if time nonlocality (memory) is present. A practical realization of self-organizing logic gates (SOLGs) can be done by combining circuit elements with and without memory. By employing one such realization, we show, numerically, that SOLGs exploit elementary instantons to reach equilibrium points. Instantons are classical trajectories of the nonlinear equations of motion describing SOLGs and connect topologically distinct critical points in the phase space. By linear analysis at those points, we show that these instantons connect the initial critical point of the dynamics, with at least one unstable direction, directly to the final fixed point. We also show that the memory content of these gates affects only the relaxation time to reach the logically consistent solution. Finally, we demonstrate, by solving the corresponding stochastic differential equations, that, since instantons connect critical points, noise and perturbations may change the instanton trajectory in the phase space but not the initial and final critical points. Therefore, even for extremely large noise levels, the gates self-organize to the correct solution. Our work provides a physical understanding of, and can serve as an inspiration for, models of bidirectional logic gates that are emerging as important tools in physics-inspired, unconventional computing.

  7. Iron Gates Natural Park - Administration and Management

    Directory of Open Access Journals (Sweden)

    Sînziana Pauliuc

    2016-11-01

    Full Text Available This paper analyzes the management and administration of one of the largest, beautiful and complex natural parks from Romania, the Iron Gates Natural Park. The management plan is a frame of integration of the biodiversity conservation problems and protection of the natural and cultural environment that also supports socio-economic development of Iron Gates Natural Park. It is also an instrument of dialog between the institutions which coordinate this area. The management plan is a document approved by H.G 1048/2013 and it resulted after consulting the interested factors of the area (city halls, local and central authorities, civil society. The administration of Iron Gates Natural Park has a new structure, founded in 2003 and is working as a subunit of Forest-National Administration (Romsilva, which assures the necessary personal and equipment for administrating the area. The area has the status of: Natural Park, Natura 2000 and Ramsar site. The forest represents 65% of the total area, 98% being a state property. Analysing Iron Gates Natural Park documents (Iron Gates Natural Park management plan, scientific council and park administration documents, visits and observations within park, we can conclude that the park has a good administration leaded by the scientific councils, who also achieved many successful European projects.

  8. The pollution of the 'iron gate' reservoir

    International Nuclear Information System (INIS)

    Babic-Mladenovic, M.; Varga, S; Popovic, L.; Damjanovic, M.

    2002-01-01

    The paper presents the characteristics of the Iron Gate I (the Djerdap) Water Power and Navigational System, one of the largest in Europe (completed in 1972 by joint efforts of Yugoslavia and Romania). In this paper the attention is devoted to review of the sediment monitoring program and impacts of reservoir sedimentation, as well as to the investigations of water and sediment quality. Special consideration is paid to the issue of sediment pollution research needs. Namely, the hot spot of the 'Iron Gate' sedimentation represents a scarcely known pollution of sediment deposits. The present pollution probably is considerable, since the 'Iron Gate' reservoir drains about 577000 km 2 , with over 80 million inhabitants, and developed municipal and industrial infrastructure. Therefore, in the thirty-year reservoir life various types of sediment-bound pollutants entered and deposited within it. Especially severe incidents happened during 1999 (as a result of NATO bombing campaign) and 2000 (two accidental pollutions in the Tisza river catchment). The study of the 'Iron Gate' reservoir pollution should be prepared in order to enlighten the present state of reservoir sedimentation and pollution. The main objectives of the study are to enhance the government and public awareness of the present environmental state of the 'Iron Gate' reservoir and to serve as a baseline for all future actions. (author)

  9. Noisy signaling through promoter logic gates.

    Science.gov (United States)

    Gerstung, Moritz; Timmer, Jens; Fleck, Christian

    2009-01-01

    We study the influence of noisy transcription factor signals on cis-regulatory promoter elements. These elements process the probability of binary binding events analogous to computer logic gates. At equilibrium, this probability is given by the so-called input function. We show that transcription factor noise causes deviations from the equilibrium value due to the nonlinearity of the input function. For a single binding site, the correction is always negative resulting in an occupancy below the mean-field level. Yet for more complex promoters it depends on the correlation of the transcription factor signals and the geometry of the input function. We present explicit solutions for the basic types of AND and OR gates. The correction size varies among these different types of gates and signal types, mainly being larger in AND gates and for correlated fluctuations. In all cases we find excellent agreement between the analytical results and numerical simulations. We also study the E. coli Lac operon as an example of an AND NOR gate. We present a consistent mathematical method that allows one to separate different sources of noise and quantifies their effect on promoter occupation. A surprising result of our analysis is that Poissonian molecular fluctuations, in contrast to external fluctuations, do no contribute to the correction.

  10. Biventricular Mechanical Circulatory Support Does Not Prevent Delayed Myocardial Ventricular Rupture following Myocardial Infarction

    Directory of Open Access Journals (Sweden)

    Yazhini Ravi

    2013-01-01

    Full Text Available Cardiogenic shock and myocardial rupture can complicate an acute myocardial infarction (AMI. A case is reported in which a 58-year-old male with an acute inferior myocardial infarction required placement of biventricular assist device for hemodynamic support eight days after the onset of his AMI; eleven days after his AMI, the patient developed abrupt onset of hemodynamic instability with massive bleeding from his chest tube due to delayed free wall myocardial rupture that was discovered when he was taking emergently to the operating room. Myocardial rupture in patients with a ventricular assist device should be considered in the differential diagnosis in the event of acute hemodynamic compromise. A high level of suspicion for such a complication should prompt aggressive and emergent actions including surgery. We present a case of delayed free wall myocardial rupture following an acute inferior wall myocardial infarction in a patient with biventricular mechanical circulatory support.

  11. Myocardial infarction and nocturnal hypoxaemia

    Directory of Open Access Journals (Sweden)

    Penčić Biljana

    2007-01-01

    Full Text Available Introduction: There is an increased risk of cardiovascular morbidity and mortality in patients with nocturnal intermittent hypoxaemia. Objecive. The aim of this study was to evalute the influence of nocturnal hypoxaemia on ventricular arrhythmias and myocardial ischaemia in patients with myocardial infarction (MI. Method. We studied 77 patients (55.8±7.9 years with MI free of complications, chronic pulmonary diseases, abnormal awake blood gases tension. All patients underwent overnight pulse oximetry and 24-hour electrocardiography. Patients were divided into two groups according to nocturnal hypoxaemia. Total number of ventricular premature complex (VPC; maximal VPC/h; incidence of VPC Lown class>2 and occurrence of ST-segment depression were analyzed for nocturnal (10 PM to 6 AM, daytime (6 AM to 22 PM periods and for the entire 24 hours. Results. Both groups were similar in age, gender, standard risk factors, myocardial infarction size and did not differ in VPC during the analyzed periods. The number of nocturnal maximal VPC/h was insignificantly greater in group 1 (with hypoxaemia compared to group 2 (without hypoxaemia, (p=0.084. Maximal VPC/h did not differ significantly either for daytime or for 24 hours among the groups. Nocturnal VPC Lown>2 were significantly more frequent in group 1 (25% vs 0%, p=0.002. The incidence of VPC Lown>2 was similar during the daytime, and during 24 hrs in both groups. Occurrence of ST-segment depression did not differ between groups 1 and 2. Conclusion. Nocturnal hypoxaemia was associated with complex nocturnal ventricular arrhythmias in patients with MI. .

  12. Nifedipine for angina and acute myocardial ischemia

    NARCIS (Netherlands)

    P.G. Hugenholtz (Paul); J.W. de Jong (Jan Willem); P.D. Verdouw (Pieter); P.W.J.C. Serruys (Patrick)

    1983-01-01

    textabstractThis paper reviews the mechanisms believed to be responsible for myocardial ischaemia and the mode of action of calcium antagonist drugs. The clinical management of patients with myocardial ischaemia is discussed in the context of current knowledge about patho-physiology and drug action.

  13. Myocardial imaging in patients with Kawasaki disease

    International Nuclear Information System (INIS)

    Ono, Yasuo; Tanimoto, Takeshi; Kijima, Yoshitami; Kohata, Tohru; Suzuki, Atsuko

    1982-01-01

    Thallium-201 myocardial imaging was performed in 80 children with coronary arterial lesions due to Kawasaki disease in order to assess the value of serial and exercise myocardial imagings. In eight of these children, abnormalities of the image were noted. Twenty children had serial thallium studies with an interval of three to 18 months, and five of these showed changes in the image including appearance of a new perfusion defect in one patient and improvement of perfusion defects in four. These changes of the myocardial image were correlated well with coronary angiographic findings obtained within a few days of the isotope studies. It was noted that the changes of the myocardial image were more frequently observed at relatively recent period recovered from Kawasaki disease. Exercise myocardial imaging using a bicycle ergometer was performed in eight children with coronary arterial lesions. In three an evidence of improvement of the myocardial perfusion was noted immediately after exercise as well as on the delayed image. In one patient, a decrease of the perfusion in the apex and inferior wall was noted immediately after exercise. On the observed image, image of the apex improved but that of the inferior wall remained hypoperfused. Thus thallium-201 myocardial imaging was considered to permit the best noninvasive documentation imaging was found to be useful in differentiating the viable from nonviable myocardium. It was to be emphasized that quantitative evaluation by computer-assisted analysis was particularly valuable in detecting small areas and in a comparison of the myocardial images. (author)

  14. Do episodes of anger trigger myocardial infarction?

    DEFF Research Database (Denmark)

    Möller, J; Hallqvist, J; Diderichsen, Finn

    1999-01-01

    Our objectives were to study anger as a trigger of acute myocardial infarction (MI) and to explore potential effect modification by usual behavioral patterns related to hostility.......Our objectives were to study anger as a trigger of acute myocardial infarction (MI) and to explore potential effect modification by usual behavioral patterns related to hostility....

  15. The end of the unique myocardial band

    DEFF Research Database (Denmark)

    MacIver, David H; Partridge, John B; Agger, Peter

    2018-01-01

    Two of the leading concepts of mural ventricular architecture are the unique myocardial band and the myocardial mesh model. We have described, in an accompanying article published in this journal, how the anatomical, histological and high-resolution computed tomographic studies strongly favour...

  16. ANGIOTENSIN II AND MYOCARDIAL INFARCTION

    Directory of Open Access Journals (Sweden)

    O. P. Shevchenko

    2008-01-01

    Full Text Available The role of angiotensin II in pathogenesis of cardiovascular diseases is discussed. Angiotensin II participates in development of acute myocardial infarction (MI in patients with atherosclerosis. It contributes to inflammation of vessel intimae, oxidative stress, cells apoptosis, matrix remodeling, has pro-thrombosis action, promotes MI expansion and post-MI remodeling. Angiotensin converting enzyme (ACE inhibitors reduce mortality and improve prognosis of patients with acute MI. In patients with ischemic heart disease including patients after MI ACE inhibitors reduce mortality, risk of repeated MI as well as improve quality of life.

  17. Ventricular and myocardial scintiscanning: Methodical fundamentals

    International Nuclear Information System (INIS)

    Standke, R.; Hoer, G.; Maul, F.D.

    1984-01-01

    Nuclear cardiology is concerned with non invasive procedures to quantitate global and regional left ventricular function (Radionuclide ventriculography), also the imaging of vitally perfused myocardium (Myocardial scintigraphy) is achieved. A gammacamera and a minicomputer are necessary. Radionuclide ventriculography enables the analysis of global and regional time dependent left ventricular volume curves and hence the evaluation of contraction and contractility of the heart muscle. The basis is a sequence of scans covering an average heartcycle. This sequence may be produced either by first pass or equilibrium technique. Myocardial scintigraphy at rest images vital myocardium, scans immediately after exercise represent the interference of myocardial perfusion and muscle mass. The regional difference (Redistribution) between normalized exercise- and rest scans provide quantitative parameters to detect impairment of exercise-induced myocardial perfusion anomalies. The procedures of sectorial analysis of left ventricular function and myocardial perfusion are presented. (orig.) [de

  18. Four-gate transistor analog multiplier circuit

    Science.gov (United States)

    Mojarradi, Mohammad M. (Inventor); Blalock, Benjamin (Inventor); Cristoloveanu, Sorin (Inventor); Chen, Suheng (Inventor); Akarvardar, Kerem (Inventor)

    2011-01-01

    A differential output analog multiplier circuit utilizing four G.sup.4-FETs, each source connected to a current source. The four G.sup.4-FETs may be grouped into two pairs of two G.sup.4-FETs each, where one pair has its drains connected to a load, and the other par has its drains connected to another load. The differential output voltage is taken at the two loads. In one embodiment, for each G.sup.4-FET, the first and second junction gates are each connected together, where a first input voltage is applied to the front gates of each pair, and a second input voltage is applied to the first junction gates of each pair. Other embodiments are described and claimed.

  19. TOURISM IN THE TOURIST AREA "IRON GATES"

    Directory of Open Access Journals (Sweden)

    DINU LOREDANA

    2015-12-01

    Full Text Available This paper wants to highlight the trends of tourist demanding from the touristic area Iron Gates. We will see that the future of tourism include new forms such as those caused by the increased interest in areas with agritourism attractions or areas and portions of parks and nature reserves, which will raise the attractiveness of Danube, putting in a new pole of attraction area. Thus, we conducted a research based on survey among visitors on the tourist area "Iron Gates". The main endpoint based on survey was highlighting the motivation that determined the choice of the tourist area "Iron Gates", but also knowledge of consumer satisfaction for the tourists to the visited area (tourist product studied. The main objectives were, of course, linked with socio - economic and demographic characteristics of tourists to form a clearer picture of the motivational factors involved.

  20. Active gated imaging for automotive safety applications

    Science.gov (United States)

    Grauer, Yoav; Sonn, Ezri

    2015-03-01

    The paper presents the Active Gated Imaging System (AGIS), in relation to the automotive field. AGIS is based on a fast gated-camera equipped with a unique Gated-CMOS sensor, and a pulsed Illuminator, synchronized in the time domain to record images of a certain range of interest which are then processed by computer vision real-time algorithms. In recent years we have learned the system parameters which are most beneficial to night-time driving in terms of; field of view, illumination profile, resolution and processing power. AGIS provides also day-time imaging with additional capabilities, which enhances computer vision safety applications. AGIS provides an excellent candidate for camera-based Advanced Driver Assistance Systems (ADAS) and the path for autonomous driving, in the future, based on its outstanding low/high light-level, harsh weather conditions capabilities and 3D potential growth capabilities.

  1. The Airport Gate Assignment Problem: A Survey

    Science.gov (United States)

    Ghaleb, Mageed A.; Salem, Ahmed M.

    2014-01-01

    The airport gate assignment problem (AGAP) is one of the most important problems operations managers face daily. Many researches have been done to solve this problem and tackle its complexity. The objective of the task is assigning each flight (aircraft) to an available gate while maximizing both conveniences to passengers and the operational efficiency of airport. This objective requires a solution that provides the ability to change and update the gate assignment data on a real time basis. In this paper, we survey the state of the art of these problems and the various methods to obtain the solution. Our survey covers both theoretical and real AGAP with the description of mathematical formulations and resolution methods such as exact algorithms, heuristic algorithms, and metaheuristic algorithms. We also provide a research trend that can inspire researchers about new problems in this area. PMID:25506074

  2. Four-year prognosis of 254 patients after acute myocardial infarction

    International Nuclear Information System (INIS)

    Nishimura, Tohru; Taya, Makoto; Sasaki, Akira; Shimoyama, Katsuya; Mizuno, Haruyoshi; Tahara, Yorio; Ono, Akifumi; Okada, Michio; Ishikawa, Kyozo

    1994-01-01

    The present study was undertaken to determine whether left ventricular diastolic function can be used as a measure for assessing prognosis of patients with acute myocardial infarction. The subjects were 254 patients who had Tc-99m gated blood pool scintigraphy within one month after the onset of myocardial infarction and could be followed up for the subsequent 4 years. The following indices for left ventricular diastolic function were calculated from the time activity curve of the left ventricle: time to peak filling, time to peak filling/t, peak filling rate, peak filling rate/t, 1/3 filling rate/t, and time per beat. On the basis of the morphology of the time activity curve and the primary differential curve, left ventricular diastolic function was visually assessed as normal (Group 0, n=30), slightly decreased (Group 1, n=98), moderately decreased (Group 2, n=81) and severely decreased (Group 3, n=45). The incidences of cardiac failure and cardiac death were remarkably increased when left ventricular ejection fraction (LVEF) was less than 30%. The incidence of cardiac failure tended to be increased in patients with severer diastolic function; it was remarkably high in Group 3. Cardiac failure was more often associated with more decreased diastolic function, even if LVEF was 40% or more. These findings suggest that left ventricular diastolic function may be helpful for assessing prognosis of acute myocardial infarction. (N.K.)

  3. Frequency of myocardial injury after blunt chest trauma as evaluated by radionuclide angiography

    Energy Technology Data Exchange (ETDEWEB)

    Sutherland, G.R.; Driedger, A.A.; Holliday, R.L.; Cheung, H.W.; Sibbald, W.J.

    1983-11-01

    Seventy-seven patients who had sustained multisystem trauma, including severe blunt chest injury, were prospectively evaluated to assess the frequency of associated traumatic myocardial injury. Traumatic injury to either the right or left ventricle was defined by the presence of discrete abnormalities of wall motion on electrocardiographically gated cardiac scintigraphy in patients without a clinical history of heart disease. Forty-two patients (55%) (Group 1) had focal abnormalities of wall motion; 27 involved the right ventricle, 7 the left ventricle, 7 were biventricular, and 1 involved only the septum. Both the right and left ventricular ejection fractions were significantly lower (31 +/- 11% and 47 +/- 14%, respectively) than those in the 35 traumatized patients without wall motion abnormalities on scintigraphy (Group 2) (49 +/- 8% and 58 +/- 11%, respectively). Repeat scintigraphic examination in 32 Group 1 patients at a time remote from initial injury showed improvement or resolution of previously defined focal wall motion abnormalities in 27 of 32 patients (84%). The electrocardiogram and serum enzyme tests were insensitive indexes of traumatic myocardial injury when defined by the scintigraphic abnormalities. Thus, severe blunt chest trauma results in a higher frequency of traumatic myocardial injury than heretofore recognized, and frequently involves the anteriorly situated right ventricle.

  4. Left ventricular volume during supine exercise: importance of myocardial scar in patients with coronary heart disease

    International Nuclear Information System (INIS)

    Mann, D.L.; Scharf, J.; Ahnve, S.; Gilpin, E.

    1987-01-01

    Existing studies suggest that exercise-induced ischemia produces an increase in left ventricular end-diastolic volume; however, all of these studies have included patients with previous myocardial infarction. To test whether the end-diastolic volume response to exercise is related to the extent of myocardial scar, the results of gated radionuclide supine exercise tests performed on 130 subjects were reviewed. The patient group comprised 130 subjects were reviewed. The patient group comprised 130 men aged 35 to 65 years (mean +/- SD 52 +/- 5) with documented coronary heart disease. The extent of myocardial ischemia and scar formation was assessed by stress electrocardiography and thallium-201 scintigraphy. Patients were classified into three groups on the basis of left ventricular end-diastolic volume response at peak exercise: group 1 (n = 72) had an increase of end-diastolic volume greater than 10%, group 2 (n = 41) had a change in end-diastolic volume less than 10% and group 3 (n = 17) had a decrease in end-diastolic volume greater than 10% (n = 17). At rest there was no significant difference among groups in heart rate, systolic blood pressure, end-diastolic (EDVrest) or end-systolic volumes or ejection fraction (p greater than 0.05); however, at peak exercise the end-systolic volume response was significantly greater for group 1 (p less than 0.002)

  5. Influence of myocardial infarction size on radionuclide and Doppler echocardiographic measurements of diastolic function

    Energy Technology Data Exchange (ETDEWEB)

    Johannessen, K.A.; Cerqueira, M.D.; Stratton, J.R. (Seattle Veterans Administration Medical Center, WA (USA))

    1990-03-15

    To assess the relation between myocardial infarction size and diastolic function as measured by radionuclide ventriculography and Doppler echocardiography, 83 patients (aged 58 +/- 9 years) without significant valvular disease were studied 8 to 12 weeks after an acute myocardial infarction. Myocardial infarction size was measured by resting thallium-201 tomography. Peak early filling rate (in end-diastolic volumes/s) was measured by gated blood pool scintigraphy. Doppler measures of mitral inflow were peak early (E) and atrial (A) filling velocities, slopes of E and A, percent E and A filling, E/A ratio and diastolic filling period. In univariate analyses, there was a significant inverse correlation between infarction size and the peak early filling rate (r = -0.59, p less than 0.001), and this remained significant (r = -0.63, p less than 0.0001) in an analysis that included 2 other determinants of the filling rate, age and diastolic filling period. Infarction size was directly correlated to the peak E velocity (r = 0.37, p less than 0.01), deceleration of E (r = 0.41, p less than 0.01) and percent E filling (r = 0.31, p less than 0.01), and was inversely correlated to peak A (r = -0.27, p less than 0.05) and percent A filling (r = -0.26, p less than 0.05).

  6. Pressure Sensitive Insulated Gate Field Effect Transistor

    Science.gov (United States)

    Suminto, James Tjan-Meng

    A pressure sensitive insulated gate field effect transistor has been developed. The device is an elevated gate field-effect-transistor. It consists of a p-type silicon substrate in which two n^+ region, the source and drain, are formed. The gate electrode is a metal film sandwiched in an insulated micro-diaphragm resembling a pill-box which covers the gate oxide, drain, and source. The space between the gate electrode and the oxide is vacuum or an air-gap. When pressure is applied on the diaphragm it deflects and causes a change in the gate capacitance, and thus modulates the conductance of the channel between source and drain. A general theory dealing with the characteristic of this pressure sensitive insulated gate field effect transistor has been derived, and the device fabricated. The fabrication process utilizes the standard integrated circuit fabrication method. It features a batch fabrication of field effect devices followed by the batch fabrication of the deposited diaphragm on top of each field effect device. The keys steps of the diaphragm fabrication are the formation of spacer layer, formation of the diaphragm layer, and the subsequent removal of the spacer layer. The chip size of the device is 600 μm x 1050 mum. The diaphragm size is 200 μm x 200 mum. Characterization of the device has been performed. The current-voltage characteristics with pressure as parameters have been demonstrated and the current-pressure transfer curves obtained. They show non-linear characteristics as those of conventional capacitive pressure sensors. The linearity of threshold voltage versus pressure transfer curves has been demonstrated. The temperature effect on the device performances has been tested. The temperature coefficient of threshold voltage, rather than the electron mobility, has dominated the temperature coefficient of the device. Two temperature compensation schemes have been tested: one method is by connecting two identical PSIGFET in a differential amplifier

  7. Ge /Si heteronanocrystal floating gate memory

    Science.gov (United States)

    Li, Bei; Liu, Jianlin; Liu, G. F.; Yarmoff, J. A.

    2007-09-01

    Metal oxide semiconductor field effect transistor memories with Ge /Si heteronanocrystals (HNCs) as floating gate were fabricated and characterized. Ge /Si HNCs with density of 5×1011cm-2 were grown on n-type Si (100) substrate with thin tunnel oxide on the top. Enhanced device performances including longer retention time, faster programming speed, and higher charge storage capability are demonstrated compared with Si nanocrystal (NC) memories. The erasing speed and endurance performance of Ge /Si HNC memories are similar to that of Si NC devices. The results suggest that Ge /Si HNCs may be an alternative to make further floating gate memory scaling down possible.

  8. Regional cerebral blood flow as assessed by principal component analysis and 99mTc-HMPAO SPET in healthy subjects at rest: normal distribution and effect of age and gender

    International Nuclear Information System (INIS)

    Pagani, M.; Salmaso, D.; Jonsson, C.; Hatherly, R.; Larsson, S.A.; Jacobsson, H.; Waegner, A.

    2002-01-01

    The increasing implementation of standardisation techniques in brain research and clinical diagnosis has highlighted the importance of reliable baseline data from normal control subjects for inter-subject analysis. In this context, knowledge of the regional cerebral blood flow (rCBF) distribution in normal ageing is a factor of the utmost importance. In the present study, rCBF was investigated in 50 healthy volunteers (25 men, 25 women), aged 31-78 years, who were examined at rest by means of single-photon emission tomography (SPET) using technetium-99m d,l-hexamethylpropylene amine oxime (HMPAO). After normalising the CBF data, 27 left and 27 right volumes of interest (VOIs) were selected and automatically outlined by standardisation software (computerised brain atlas). The heavy load of flow data thus obtained was reduced in number and grouped in factors by means of principal component analysis (PCA). PCA extracted 12 components explaining 81% of the variance and including the vast majority of cortical and subcortical regions. Analysis of variance and regression analyses were performed for rCBF, age and gender before PCA was applied and subsequently for each single extracted factor. There was a significantly higher CBF on the right side than on the left side (P<0.001). In the overall analysis, a significant decrease was found in CBF (P=0.05) with increasing age, and this decrease was particularly evident in the left hemisphere (P=0.006). When gender was specifically analysed, CBF was found to decrease significantly with increasing age in females (P=0.037) but not in males. Furthermore, a significant decrease in rCBF with increasing age was found in the brain vertex (P=0.05), left frontotemporal cortex (P=0.012) and temporocingulate cortex (P=0.003). By contrast, relative rCBF in central structures increased with age (P=0.001). The ability of standardisation software and PCA to identify functionally connected brain regions might contribute to a better

  9. Risk assessment after coronary angioplasty with SPECT myocardial perfusion studies

    International Nuclear Information System (INIS)

    Camilletti, Jorge A.; Erriest, Juan; Mele, Anibal A.

    2007-01-01

    The chest pain can be use for stratifying the risk of the patients after coronary angioplasty. Nevertheless this strategy has shown to have a low accuracy in the detection of restenosis and myocardial ischemia. Aims: To establish the usefulness of the SPECT studies in the risk stratification after the coronary angioplasty. Evaluate the incidence of silent ischemia or symptomatic, and its impact on the prognosis. Method: There were included 107 patients (p) submitted to a gated SPECT between the year of the coronary angioplasty. The analysis of the images was performed according to different scores (SSS, SRS, SDS). These data was correlated with the symptoms of the patients. We define group 1 (G1) as the asymptomatic without ischemia (n 59p), group 2 (G2) as silent ischemia (n = 28p) and group 3 (G3) as symptomatic with ischemia (n = 20p). A clinical follow-up was done in search of events (target vessel revascularization, unstable angina, AMI and death). Results: Significant differences were not observed in the clinical variables between the different groups. The SSS was lower in the G1 compare with G2 and G3 (p 0.0001) and was similar between the last two, p = NS (SSS: G1: 2.2 ± 4.9; G2: 7.6 ± 5.9; G3: 9.5 ± 6.8). The SDS was greater in G3 vs. G1 and G2, p = 0.0001, and greater in G2 vs. G1, p = 0.0001 (SDS: G1: 0; G2: 4.8 ± 3.5; G3: 7.2 ± 6.5). No differences where observed in the SRS between the three groups. In the follow-up the total percentage of events was lesser when compare the G1 with the G2 and G3 (G1: 3.3%; G2 and G3: 18.7%; p 0.02). The percentage of annual events of the G3 symptomatic with ischemia (11.03%) and G2 silent ischemia (4.04%) did not present differences (p 0.7). When the events of the G2 (4.04%) were compared with the G1 (1.24%) we observed a trend to major frequency of events in the G2 (p = 0.6). Conclusions: The presence of myocardial ischemia after coronary angioplasty is a determinant of the prognosis. Nevertheless, the extension

  10. Gate-Controlled WSe2Transistors Using a Buried Triple-Gate Structure.

    Science.gov (United States)

    Müller, M R; Salazar, R; Fathipour, S; Xu, H; Kallis, K; Künzelmann, U; Seabaugh, A; Appenzeller, J; Knoch, J

    2016-12-01

    In the present paper, we show tungsten diselenide (WSe 2 ) devices that can be tuned to operate as n-type and p-type field-effect transistors (FETs) as well as band-to-band tunnel transistors on the same flake. Source, channel, and drain areas of the WSe 2 flake are adjusted, using buried triple-gate substrates with three independently controllable gates. The device characteristics found in the tunnel transistor configuration are determined by the particular geometry of the buried triple-gate structure, consistent with a simple estimation of the expected off-state behavior.

  11. Complications of myocardial infarction on multidetector-row computed tomography of chest

    Energy Technology Data Exchange (ETDEWEB)

    Raj, V.; Karunasaagarar, K. [Department of Radiology, Papworth and Addenbrookes Hospital, Cambridge (United Kingdom); Rudd, J.H.F. [Division of Cardiovascular Medicine, University of Cambridge, Cambridge (United Kingdom); Screaton, N. [Department of Radiology, Papworth and Addenbrookes Hospital, Cambridge (United Kingdom); Gopalan, D., E-mail: deepa.gopalan@btopenworld.co [Department of Radiology, Papworth and Addenbrookes Hospital, Cambridge (United Kingdom)

    2010-11-15

    Myocardial infarction (MI) secondary to coronary artery disease remains the leading cause of death in the western world. The advent of early reperfusion therapy has substantially decreased in-hospital mortality and has improved the outcome in survivors of the acute phase of MI. Complications of MI include ischaemic, mechanical, arrhythmic, embolic and inflammatory disturbances. Although some of these complications may be infrequent, their importance is underscored because of the potential ability to correct them with early diagnosis and appropriate treatment. The majority of these complications will be detected on clinical examination and confirmed by echocardiography. Some patients may undergo non-electrocardiogram (ECG)-gated thoracic multidetector-row computed tomography (MDCT) due to non-specific presentation. In this group, it is imperative for the radiologist to be aware of and be confident in diagnosing the complications secondary to MI. This review illustrates the spectrum and imaging features of acute and chronic complications of MI that can be visualized on both ECG-gated cardiac and non-ECG-gated thoracic MDCT.

  12. Diagnostic and prognostic role of myocardial perfusion scintigraphy in kidney transplant candidates: narrative review

    Directory of Open Access Journals (Sweden)

    Alberto Bestetti

    2016-10-01

    Full Text Available PurposeCardiac screening in adult kidney transplant candidates with myocardial perfusion scintigraphy (MPS can reveal findings associated with increased risk for coronary heart disease events, but the exact value of this screening test is still undetermined.MethodsNarrative review based on the available literature and guidelines on the yield, benefits, and harms of MPS screening in kidney transplant candidates.ResultsAlthough coronary angiography carries low risk in general population, it is not without risk particularly in patients with complex comorbid disease and the use of intravenous contrast media may precipitate a need for hospitalization and death. We could avoid invasive coronary angiography in patients with chronic kidney disease, although with high coronary calcium score, but good left ventricle function and normal perfusion, evaluated by Gated single-photon emission computed tomographic (SPECT MPS. In fact, although Gated SPECT MPS has not a high sensitivity, it provides some variables that are closely related to sudden death: post-stress and rest-ejection fraction and left ventricular volumes, left ventricle muscle mass, extent of ischemia and scar.ConclusionsGated SPECT MPS is a valid noninvasive cardiac screening test. It can be used as alternative to stress echocardiography in kidney transplant candidates with high cardiovascular risk and a positive or inconclusive exercise tolerance ECG test.Patients with abnormal perfusion and cardiac dysfunction should undergo invasive coronary artery imaging and endovascular treatment, while angiography could be avoided in patients with normal MPI, having good long-term prognosis.

  13. Risk factors for acute myocardial infarction during the postoperative period of myocardial revascularization

    Directory of Open Access Journals (Sweden)

    José Ribamar Costa Jr.

    2003-03-01

    Full Text Available OBJECTIVE: To identify risk factors for acute myocardial infarction during the postoperative period after myocardial revascularization. METHODS: This was a case-control study paired for sex, age, number, type of graft used, coronary endarterectomy, type of myocardial protection, and use of extracorporeal circulation. We assessed 178 patients (89 patients in each group undergoing myocardial revascularization, and the following variables were considered: dyslipidemia, systemic hypertension, smoking, diabetes mellitus, previous myocardial revascularization surgery, previous coronary angioplasty, and acute myocardial infarction. RESULTS: Baseline clinical characteristics did not differ in the groups, except for previous myocardial revascularization surgery, prevalent in the case group (34 patients vs. 12 patients; p = 0.0002. This was the only independent predictor of risk for acute myocardial infarction in the postoperative period, based on a multivariate logistic regression analysis (p=0.0001. Mortality and the time of hospital stay of the case group were significantly higher (19.1% vs. 1.1%; p<0.001 and 15.7 days vs. 10.6 days; p<0.05 respectively than those of the control. CONCLUSION: Only previous myocardial revascularization was an independent predictor of acute myocardial infarction in the postoperative period, based on multivariate logistic regression analysis.

  14. Three-dimension structure of ventricular myocardial fibers after myocardial infarction

    Directory of Open Access Journals (Sweden)

    Li Libin

    2010-11-01

    Full Text Available Abstract Background To explore the pathological changes of three-dimension structure of ventricular myocardial fibers after anterior myocardial infarction in dog heart. Methods Fourteen acute anterior myocardial infarction models were made from healthy dogs (mean weight 17.6 ± 2.5 kg. Six out of 14 dogs with old myocardial infarction were sacrificed, and their hearts were harvested after they survived the acute anterior myocardial infarction for 3 months. Each heart was dissected into ventricular myocardial band (VMB, morphological characters in infarction region were observed, and infarct size percents in descending segment and ascending segment were calculated. Results Six dog hearts were successfully dissected into VMB. Uncorresponding damages in myocardial fibers of descending segment and ascending segment were found in apical circle in anterior wall infarction. Infarct size percent in the ascending segment was significantly larger than that in the descending segment (23.36 ± 3.15 (SD vs 30.69 ± 2.40%, P = 0.0033; the long axis of infarction area was perpendicular to the orientation of myocardial fibers in ascending segment; however, the long axis of the infarction area was parallel with the orientation of myocardial fibers in descending segment. Conclusions We found that damages were different in both morphology and size in ascending segment and descending segment in heart with myocardial infarction. This may provide an important insight for us to understand the mechanism of heart failure following coronary artery diseases.

  15. Direct Evidence that Myocardial Insulin Resistance following Myocardial Ischemia Contributes to Post-Ischemic Heart Failure

    Science.gov (United States)

    Fu, Feng; Zhao, Kun; Li, Jia; Xu, Jie; Zhang, Yuan; Liu, Chengfeng; Yang, Weidong; Gao, Chao; Li, Jun; Zhang, Haifeng; Li, Yan; Cui, Qin; Wang, Haichang; Tao, Ling; Wang, Jing; Quon, Michael J; Gao, Feng

    2015-01-01

    A close link between heart failure (HF) and systemic insulin resistance has been well documented, whereas myocardial insulin resistance and its association with HF are inadequately investigated. This study aims to determine the role of myocardial insulin resistance in ischemic HF and its underlying mechanisms. Male Sprague-Dawley rats subjected to myocardial infarction (MI) developed progressive left ventricular dilation with dysfunction and HF at 4 wk post-MI. Of note, myocardial insulin sensitivity was decreased as early as 1 wk after MI, which was accompanied by increased production of myocardial TNF-α. Overexpression of TNF-α in heart mimicked impaired insulin signaling and cardiac dysfunction leading to HF observed after MI. Treatment of rats with a specific TNF-α inhibitor improved myocardial insulin signaling post-MI. Insulin treatment given immediately following MI suppressed myocardial TNF-α production and improved cardiac insulin sensitivity and opposed cardiac dysfunction/remodeling. Moreover, tamoxifen-induced cardiomyocyte-specific insulin receptor knockout mice exhibited aggravated post-ischemic ventricular remodeling and dysfunction compared with controls. In conclusion, MI induces myocardial insulin resistance (without systemic insulin resistance) mediated partly by ischemia-induced myocardial TNF-α overproduction and promotes the development of HF. Our findings underscore the direct and essential role of myocardial insulin signaling in protection against post-ischemic HF. PMID:26659007

  16. Influence of the arm position in myocardial perfusion imaging acquisition

    Directory of Open Access Journals (Sweden)

    Marisa Izaki

    2014-07-01

    Full Text Available Objective: despite the technologic advances in myocardial perfusion imaging, we keep using an uncomfortable and sometimes impracticable patient position - supine with arms raised above the head (U. The purpose of this study was to investigate whether perfusion and functional cardiac gated SPECT scan results of acquisition U are equivalent to another position modality: supine with arms down at the sides of the trunk (D. Methods and Results: we performed U acquisition and in sequence D acquisition in 120 patients (pts using a one-day MPI (rest-gated/stress, with 99mTc-sestamibi (370 MBq and 1110 MBq. Images were processed by the iterative reconstruction method (OSEM. Rest (R and stress (S studies were scored using 17-segments model. Functional parameters (left ventricular ejection fraction, and volumes were automatically obtained by the quantitative gated SPECT (QGS program. According to the degree of stress defects observed in U study, the patients were categorized in two subgroups: normal (SSS ≤ 3 or 3 or ≥ 5%. Shoulder/back pain occurred in 23.3% of U patients and in 5% of D. No significant differences between U and D were found for SSS (p = 0.82 and SRS (p = 0.74 in normal group. In abnormal group, good correlation was found between U and D modes for SSS (Rho = 0.95, p = 0.0001 and SRS (Rho = 0.96 p = 0.0001, but the mean SSS (12.53 ± 7.54 and SRS (10.60 ± 7.08 values of D were significantly lower (p < 0.05 than SSS (13.43 ± 6.81 and SRS (11.33 ± 6.97 of U mode. Function measurements presented good correlations, except for end-diastolic volume (p = 0.0001. Conclusion: although D mode appears to be more comfortable and presented a good correlation with U values of SSS and SRS, in abnormal pts, the extent and severity of defects can be underestimated. Considering clinical implications of an accurate perfusion measurement, the acquisition with the arms down should be avoided.

  17. Determination of prospective displacement-based gate threshold for respiratory-gated radiation delivery from retrospective phase-based gate threshold selected at 4D CT simulation

    International Nuclear Information System (INIS)

    Vedam, S.; Archambault, L.; Starkschall, G.; Mohan, R.; Beddar, S.

    2007-01-01

    Four-dimensional (4D) computed tomography (CT) imaging has found increasing importance in the localization of tumor and surrounding normal structures throughout the respiratory cycle. Based on such tumor motion information, it is possible to identify the appropriate phase interval for respiratory gated treatment planning and delivery. Such a gating phase interval is determined retrospectively based on tumor motion from internal tumor displacement. However, respiratory-gated treatment is delivered prospectively based on motion determined predominantly from an external monitor. Therefore, the simulation gate threshold determined from the retrospective phase interval selected for gating at 4D CT simulation may not correspond to the delivery gate threshold that is determined from the prospective external monitor displacement at treatment delivery. The purpose of the present work is to establish a relationship between the thresholds for respiratory gating determined at CT simulation and treatment delivery, respectively. One hundred fifty external respiratory motion traces, from 90 patients, with and without audio-visual biofeedback, are analyzed. Two respiratory phase intervals, 40%-60% and 30%-70%, are chosen for respiratory gating from the 4D CT-derived tumor motion trajectory. From residual tumor displacements within each such gating phase interval, a simulation gate threshold is defined based on (a) the average and (b) the maximum respiratory displacement within the phase interval. The duty cycle for prospective gated delivery is estimated from the proportion of external monitor displacement data points within both the selected phase interval and the simulation gate threshold. The delivery gate threshold is then determined iteratively to match the above determined duty cycle. The magnitude of the difference between such gate thresholds determined at simulation and treatment delivery is quantified in each case. Phantom motion tests yielded coincidence of simulation

  18. Gate errors in solid-state quantum-computer architectures

    International Nuclear Information System (INIS)

    Hu Xuedong; Das Sarma, S.

    2002-01-01

    We theoretically consider possible errors in solid-state quantum computation due to the interplay of the complex solid-state environment and gate imperfections. In particular, we study two examples of gate operations in the opposite ends of the gate speed spectrum, an adiabatic gate operation in electron-spin-based quantum dot quantum computation and a sudden gate operation in Cooper-pair-box superconducting quantum computation. We evaluate quantitatively the nonadiabatic operation of a two-qubit gate in a two-electron double quantum dot. We also analyze the nonsudden pulse gate in a Cooper-pair-box-based quantum-computer model. In both cases our numerical results show strong influences of the higher excited states of the system on the gate operation, clearly demonstrating the importance of a detailed understanding of the relevant Hilbert-space structure on the quantum-computer operations

  19. Improved Classical Simulation of Quantum Circuits Dominated by Clifford Gates

    Science.gov (United States)

    Bravyi, Sergey; Gosset, David

    2016-06-01

    We present a new algorithm for classical simulation of quantum circuits over the Clifford+T gate set. The runtime of the algorithm is polynomial in the number of qubits and the number of Clifford gates in the circuit but exponential in the number of T gates. The exponential scaling is sufficiently mild that the algorithm can be used in practice to simulate medium-sized quantum circuits dominated by Clifford gates. The first demonstrations of fault-tolerant quantum circuits based on 2D topological codes are likely to be dominated by Clifford gates due to a high implementation cost associated with logical T gates. Thus our algorithm may serve as a verification tool for near-term quantum computers which cannot in practice be simulated by other means. To demonstrate the power of the new method, we performed a classical simulation of a hidden shift quantum algorithm with 40 qubits, a few hundred Clifford gates, and nearly 50 T gates.

  20. A novel trench gate MOSFET with a multiple-layered gate oxide for high-reliability operation

    International Nuclear Information System (INIS)

    Kim, Sang Gi; Kah, Dong Ha; Na, Kyoung Il; Yang, Yil Suk; Koo, Jin Gun; Kim, Jong Dae; Lee, Jin Ho; Park, Hoon Soo

    2012-01-01

    Gate dielectrics in trench structures for trench gate metal oxide semiconductor field-effect transistor (MOSFET) power devices are very important to realize excellent characteristics. In this paper we describe multiple-layer gate dielectrics for trench gate MOSFETs with both thermal and chemical vapor deposition (CVD) gate oxides that exhibit excellent gate oxide properties and surface roughness. Through various trench etching experiments for better surface conditions in the trench, the optimum etching gas chemistry and etch conditions were found. The destruction of gate dielectric in trench gate MOSFET occurs at the top and the bottom trench corner edges. The structure of the gate electrode is pulled out with the polysilicon layer which is buried in the trench. Thus, high electric field operation is inevitable at the gate between source diffusion and the gate polysilicon. Moreover, the trench corner oxide suffers from the high electric field. We propose a multiple-gate dielectric structure of a thermal oxide and CVD oxide for highly reliable operation of the device. This enables trench surface smoothing and low thermal stress at the trench corners and provides the oxide thickness uniformity, giving superior device characteristics of high breakdown voltage and low leakage current. These improvements are caused by the excellent quality of the gate oxide and the good thickness uniformity that is formed at the inner trench with a specific geometrical factor.

  1. Reliability study of refractory gate gallium arsenide MESFETS

    Science.gov (United States)

    Yin, J. C. W.; Portnoy, W. M.

    1981-01-01

    Refractory gate MESFET's were fabricated as an alternative to aluminum gate devices, which have been found to be unreliable as RF power amplifiers. In order to determine the reliability of the new structures, statistics of failure and information about mechanisms of failure in refractory gate MESFET's are given. Test transistors were stressed under conditions of high temperature and forward gate current to enhance failure. Results of work at 150 C and 275 C are reported.

  2. Dynamic Power Reduction of Digital Circuits by ClockGating

    OpenAIRE

    Varsha Dewre; Rakesh Mandliya

    2017-01-01

    In this paper we have presented clock gating process for low power VLSI (very large scale integration) circuit design. Clock gating is one of the most quite often used systems in RTL to shrink dynamic power consumption without affecting the performance of the design. One process involves inserting gating requisites in the RTL, which the synthesis tool translates to clock gating cells in the clock-path of a register bank. This helps to diminish the switching activity on the clock network, ther...

  3. Tunable pulse-shaping with gated graphene nanoribbons

    DEFF Research Database (Denmark)

    Prokopeva, Ludmila; Emani, Naresh K.; Boltasseva, Alexandra

    2014-01-01

    We propose a pulse-shaper made of gated graphene nanoribbons. Simulations demonstrate tunable control over the shapes of transmitted and reflected pulses using the gating bias. Initial fabrication and characterization of graphene elements is also discussed.......We propose a pulse-shaper made of gated graphene nanoribbons. Simulations demonstrate tunable control over the shapes of transmitted and reflected pulses using the gating bias. Initial fabrication and characterization of graphene elements is also discussed....

  4. Myocardial perfusion imaging with dual energy CT

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Kwang Nam [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiology, SMG-SNU Boramae Medical Center, Seoul (Korea, Republic of); De Cecco, Carlo N. [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Caruso, Damiano [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiological Sciences, Oncology and Pathology, University of Rome “Sapienza”, Rome (Italy); Tesche, Christian [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Cardiology and Intensive Care Medicine, Heart Center Munich-Bogenhausen, Munich (Germany); Spandorfer, Adam; Varga-Szemes, Akos [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States)

    2016-10-15

    Highlights: • Stress dual-energy sCTMPI offers the possibility to directly detect the presence of myocardial perfusion defects. • Stress dual-energy sCTMPI allows differentiating between reversible and fixed myocardial perfusion defects. • The combination of coronary CT angiography and dual-energy sCTMPI can improve the ability of CT to detect hemodynamically relevant coronary artery disease. - Abstract: Dual-energy CT (DECT) enables simultaneous use of two different tube voltages, thus different x-ray absorption characteristics are acquired in the same anatomic location with two different X-ray spectra. The various DECT techniques allow material decomposition and mapping of the iodine distribution within the myocardium. Static dual-energy myocardial perfusion imaging (sCTMPI) using pharmacological stress agents demonstrate myocardial ischemia by single snapshot images of myocardial iodine distribution. sCTMPI gives incremental values to coronary artery stenosis detected on coronary CT angiography (CCTA) by showing consequent reversible or fixed myocardial perfusion defects. The comprehensive acquisition of CCTA and sCTMPI offers extensive morphological and functional evaluation of coronary artery disease. Recent studies have revealed that dual-energy sCTMPI shows promising diagnostic accuracy for the detection of hemodynamically significant coronary artery disease compared to single-photon emission computed tomography, invasive coronary angiography, and cardiac MRI. The aim of this review is to present currently available DECT techniques for static myocardial perfusion imaging and recent clinical applications and ongoing investigations.

  5. Corner Office Interview: Gates Foundation's Deborah Jacobs

    Science.gov (United States)

    Miller, Rebecca

    2010-01-01

    U.S. libraries gave the world a top talent when Deborah Jacobs left her transformational role as City Librarian of Seattle in 2008 to head the Bill & Melinda Gates Foundation's Global Libraries program, the international sibling to the U.S. Libraries program. The initiative fosters national-scale projects with grantees in transitioning countries…

  6. An electronically controlled automatic security access gate

    Directory of Open Access Journals (Sweden)

    Jonathan A. ENOKELA

    2014-11-01

    Full Text Available The security challenges being encountered in many places require electronic means of controlling access to communities, recreational centres, offices, and homes. The electronically controlled automated security access gate being proposed in this work helps to prevent an unwanted access to controlled environments. This is achieved mainly through the use of a Radio Frequency (RF transmitter-receiver pair. In the design a microcontroller is programmed to decode a given sequence of keys that is entered on a keypad and commands a transmitter module to send out this code as signal at a given radio frequency. Upon reception of this RF signal by the receiver module, another microcontroller activates a driver circuitry to operate the gate automatically. The codes for the microcontrollers were written in C language and were debugged and compiled using the KEIL Micro vision 4 integrated development environment. The resultant Hex files were programmed into the memories of the microcontrollers with the aid of a universal programmer. Software simulation was carried out using the Proteus Virtual System Modeling (VSM version 7.7. A scaled-down prototype of the system was built and tested. The electronically controlled automated security access gate can be useful in providing security for homes, organizations, and automobile terminals. The four-character password required to operate the gate gives the system an increased level of security. Due to its standalone nature of operation the system is cheaper to maintain in comparison with a manually operated type.

  7. Angular momentum gated neutron evaporation studies

    International Nuclear Information System (INIS)

    Banerjee, K.; Kundu, S.; Rana, T.K.; Bhattacharya, C.; Mukherjee, G.; Gohil, M.; Meena, J.K.; Pandey, R.; Pai, H.; Dey, A.; Biswas, M.; Mukhopadhyay, S.; Pandit, D.; Pal, S.; Banerjee, S.R.; Bhattacharya, S.; Bandhopadhyay, T.

    2010-01-01

    The inverse level density parameter k (k = A/a, where A is the mass number of the compound nucleus)is investigated as a function of angular momentum by measuring γ-ray fold gated neutron evaporation spectrum in 4 He + 115 In fusion reaction using 35 MeV 4 He ion beam from VECC K130 cyclotron

  8. Sensorimotor gating deficits in multiple system atrophy

    DEFF Research Database (Denmark)

    Zoetmulder, Marielle; Biernat, Heidi Bryde; Nikolic, Miki

    2014-01-01

    Prepulse inhibition (PPI) of the auditory blink reflex is a measure of sensorimotor gating, which reflects an organism's ability to filter out irrelevant sensory information. PPI has never been studied in patients with multiple system atrophy (MSA), although sensorimotor deficits are frequently...

  9. Comparison of gate capacitance extraction methodologies

    NARCIS (Netherlands)

    Kazmi, S.N.R.; Schmitz, Jurriaan

    2008-01-01

    In recent years, many new capacitance-voltage measurement approaches have been presented in literature. New approaches became necessary with the rapidly increasing gate current density in newer CMOS generations. Here we present a simulation platform using Silvaco software, to describe the full chain

  10. Nitrogen-13-labeled ammonia for myocardial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Walsh, W.F.; Fill, H.R.; Harper, P.V.

    1977-01-01

    Cyclotron-produced nitrogen-13 (half-life 10 min), as labeled ammonia (/sup 13/NH/sub 4//sup +/), has been evaluated as a myocardial perfusion imaging agent. The regional myocardial uptake of /sup 13/NH/sub 4//sup +/ has been shown to be proportional to regional tissue perfusion in animal studies. Intravenously administered /sup 13/NH/sub 4//sup +/ is rapidly cleared from the circulation, being extracted by the liver (15 percent), lungs, myocardium (2 percent--4 percent), brain, kidney, and bladder. Myocardial ammonia is metabolized mainly to glutamine via the glutamine synthetase pathway. Pulmonary uptake is substantial, but usually transient, except in smokers where clearance may be delayed. The positron annihilation irradiation (511 keV) of /sup 13/N may be imaged with a scintillation camera, using either a specially designed tungsten collimator or a pinhole collimator. After early technical problems with collimation and the production method of /sup 13/NH/sub 4//sup +/ were overcome, reproducible high quality myocardial images were consistently obtained. The normal myocardial image was established to be of a homogeneous ''doughnut'' configuration. Imaging studies performed in patients with varying manifestations of ischemic and valvular heart disease showed a high incidence of localized perfusion defects, especially in patients with acute myocardial in