WorldWideScience

Sample records for gaseous effluents metodologia

  1. Behaviour of radioiodine in gaseous effluents

    International Nuclear Information System (INIS)

    Barry, P.J.

    1968-01-01

    Because of the different chemical forms in which radioiodine occurs in the gaseous state, it is important when designing efficient filters to know the chemical forms which may be present in the effluent gases when various operations are being carried out and to know the effect of different gaseous environments on the filtration efficiency. To obtain this information it is necessary to have available reliable means of characterizing different chemical forms and to sample gaseous effluents when these operations are being carried out. This paper describes the use for identifying molecular iodine of metallic screens in a multi-component sampling pack in different gaseous environments. Using multi-component sampling packs, the fractionation of iodine nuclides between different chemical forms was measured in the effluent gases escaping from an in-pile test loop in which the fuel was deliberately ruptured by restricting the flow of coolant. Sequential samples were taken for six hours after the rupture and it was possible to follow during this period the individual behaviours of 13 '1I, 133 I and 135 I. Simultaneous samples were also obtained of the noble gases in the effluent gas stream and of the iodine nuclides in the loop coolant. Similar experiments have been carried out with a view to characterizing the different chemical behaviour of radioiodine as it is released from a variety of operations in the nuclear industry including the cutting of fuel sections in metallurgical examination caves and an incinerator. (author)

  2. Legal provisions governing gaseous effluents radiological monitoring

    International Nuclear Information System (INIS)

    Winkelmann, I.

    1985-01-01

    This contribution explains the main provisions governing radiological monitoring of gaseous effluents from LWR type nuclear power plants. KTA rule 1503.1 defines the measuring methods and tasks to be fulfilled by reactor operators in order to safeguard due monitoring and accounting of radioactive substances in the plants' gaseous effluents. The routine measurements are checked by a supervisory programme by an independent expert. The routine controls include analysis of filter samples, comparative measurement of radioactive noble gases, interlaboratory comparisons, and comparative evaluation of measured values. (DG) [de

  3. Monitoring of released radioactive gaseous and liquid effluent at Rokkasho Reprocessing Plant

    International Nuclear Information System (INIS)

    Oka, M.; Keta, S.; Nagai, S.; Kano, M.; Ishihara, N.; Moriyama, T.; Ogaki, K.; Noda, K.

    2009-01-01

    Rokkasho Reprocessing Plant (RRP) Rokkasho Reprocessing Plant started its active tests with spent fuel at the end of March 2006. When spent fuels are sheared and dissolved, radioactive gaseous effluent and radioactive liquid effluent such as krypton-85, tritium, etc. are released into the environment. In order to limit the public dose as low as reasonably achievable in an efficient way, RRP removes radioactive material by evaporation, rinsing, filtering, etc., and then releases it through the main stack and the sea discharge pipeline that allow to make dispersion and dilution very efficiently. Also, concerning the radioactive gaseous and liquid effluent to be released into the environment, the target values of annual release have been defined in the Safety Rule based on the estimated annual release evaluated at the safety review of RRP. By monitoring the radioactive material in gaseous exhaust and liquid effluent RRP controls it not to exceed the target values. RRP reprocessed 430 tUpr of spent fuel during Active Test (March 2006 to October 2008). In this report, we report about: The outline of gaseous and liquid effluent monitoring. The amount of radioactive gaseous and liquid effluent during the active test. The performance of removal of radioactive materials in gaseous and liquid effluents. The impact on the public from radioactive effluents during the active test. (author)

  4. Method of removing iodine and compounds thereof from gaseous effluents

    International Nuclear Information System (INIS)

    Keener, R.L.; Kittle, P.A.

    1976-01-01

    Anion exchange resins including an acrylic backbone formed by the suspension polymerization of a mixture of an acrylic and a crosslinking monomer are useful in the removal of iodine and iodine compounds from gaseous effluents. Removal of radioactive iodine contaminants, particularly alkyl iodine compounds or hydrogen iodine, under extreme conditions, namely temperatures up to 180 0 C and humidities up to 100 percent, from effluents resulting from a major nuclear accident could probably be adsorbed by these resins described herein

  5. Estimation of radionuclide releases in atmosphere from Cernavoda NPP based on continuous gaseous effluent monitoring

    International Nuclear Information System (INIS)

    Bobric, E.; Murgoci, S.; Popescu, I.; Ibadula, R.

    2001-01-01

    Monitoring of gaseous effluents from Cernavoda NPP is performed to assess the environmental impact of the plant operation. The results of the monitoring program are used to evaluate the population doses in order to ensure that the emissions of radionuclides in air are below regulatory limits and radiation doses are maintained ALARA. It complements, but is independent from the Operational Environmental Monitoring Program for Cernavoda NPP. Gaseous effluent monitors provide continuous indication of the radioactivity content in atmospheric emissions. Except for noble gases, these monitors also collect samples for later detailed analysis in the station Health Physics Laboratory. This paper presents the main equipment and the results of the gaseous effluents monitoring program in order to assess the impact of Cernavoda NPP operation and to predict the future releases as function of radionuclides concentrations in CANDU systems, based on the identified trends.(author)

  6. Separation of tritium from gaseous and aqueous effluent systems

    International Nuclear Information System (INIS)

    Kobisk, E.H.

    1977-01-01

    Three processes are discussed for separating tritium from gaseous and aqueous effluent systems: separation in the gas phase using Pd-25 wt percent Ag alloy diffusion membranes; electrolytic separation in the aqueous phase using ''bipolar'' electrodes; and the countercurrent exchange of tritium-containing hydrogen gas with water on catalytic surfaces combined with separation by direct electrolysis

  7. Operational experience of gaseous effluent treatment at the Eurochemic reprocessing plant

    International Nuclear Information System (INIS)

    Osipenco, A.; Detilleux, E.

    1977-01-01

    The EUROCHEMIC fuel reprocessing plant applies the PUREX flow sheet. Two particular features of the plant influence gaseous and liquid effluents: chemical decanning and the ability to process a wide range of fuels, uranium metal or oxide, having an initial enrichment typical of power reactors (up to 5%) or material testing reactors (up to 93%). The ventilation circuits, treatment plant and monitoring equipment for gaseous releases are briefly described. No retention facilities for rare gases, tritium, or carbon-14 are provided. The releases are monitored for krypton-85, iodine-131, alpha and beta-gamma aerosols and tritium. Between 1966 and 1974 the plant processes about 200 tonnes of power reactor fuel, from which about 0.7 tonnes of plutonium and 1.5 tonnes of highly enriched uranium were separated. The most important points in the operation of the gas cleaning equipment are indicated: efficiency, operational reliability, incidents, etc.. Actual discharges as measured are compared with the limits set in the operation licence. Using the atmospheric diffusion coefficients, the dose commitment is estimated. The low level liquid effluents are passed, after neutralization, to the treatment plant of the Belgian nuclear center CEN/SCK. However, if the activity exceeds the limit set by the CEN/SCK, the effluents are concentrated by evaporation and stored on the EUROCHEMIC site. (orig.) [de

  8. Control of semivolatile radionuclides in gaseous effluents at nuclear facilities

    International Nuclear Information System (INIS)

    1982-01-01

    An up-to-date review is presented of the subject, combining the results of laboratory studies on control of the most important semivolatile radionuclides in gaseous effluents at nuclear facilities and the results of operating experience in that area. Ruthenium is the most significant semivolatile contaminant in gaseous effluents at nuclear facilities. Volatilization of ruthenium can be reduced by various means, in particular by adding reductants. Volatilized ruthenium can be retained by adsorbents such as silica gel and ferric-oxide-based materials. Decontamination factors in the order of 10 3 have been obtained with these adsorbents under optimum conditions. Volatilized ruthenium can also be removed by other equipment such as condensers and scrubbers. Experience with high-level liquid waste solidification plants has shown that, in general, ruthenium volatilization is in the order of 10% or more unless special treatment is undertaken. There is little experience with ruthenium adsorbers in plants. Silica gel seems to have performed best, with ruthenium decontamination factors of about 10 2 to 10 3 . However, feed-to-stack ruthenium decontamination factors of 10 9 or more have been obtained even without ruthenium adsorbers. Other semivolatiles are relatively insignificant under normal conditions because of a low level of volatilization potential or mass or activity in the inventory. Moreover, owing to particulate formation, they can be easily removed without specific equipment

  9. Gaseous effluent monitoring and identification using an imaging Fourier transform spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Carter, M.R.; Bennett, C.L.; Fields, D.J.; Hernandez, J.

    1993-10-01

    We are developing an imaging Fourier transform spectrometer for chemical effluent monitoring. The system consists of a 2-D infrared imaging array in the focal plane of a Michelson interferometer. Individual images are coordinated with the positioning of a moving mirror in the Michelson interferometer. A three dimensional data cube with two spatial dimensions and one interferogram dimension is then Fourier transformed to produce a hyperspectral data cube with one spectral dimension and two spatial dimensions. The spectral range of the instrument is determined by the choice of optical components and the spectral range of the focal plane array. Measurements in the near UV, visible, near IR, and mid-IR ranges are possible with the existing instrument. Gaseous effluent monitoring and identification measurements will be primarily in the ``fingerprint`` region of the spectrum, ({lambda} = 8 to 12 {mu}m). Initial measurements of effluent using this imaging interferometer in the mid-IR will be presented.

  10. Determination of Kr-85 in environmental samples and gaseous effluents from nuclear industries using the standard method

    International Nuclear Information System (INIS)

    Heras Iniquez, M.C.; Perez Garcia, M.M.

    1983-01-01

    The determination of the Kr-85 activity in environmental samples and gaseous effluents from Spanish Nuclear Power Stations is described. The method employed has been published elsewhere. The determinations has been carried out in environmental samples token at JEN Laboratories (Madrid) and the Nuclear Power Stations, Jose Cabrera (Zorita), Garona and Vandellos. Also samples of gaseous effluents of the three plants has been analyzed. Values of the Kr-85 environmental background activity in the Almaraz Nuclear Power Stations, has been determined, before the beginning of its nuclear activity. In this paper the sampling equipment used is described and the values found of Kr-85 activity in all the samples in given. (Author) 29 refs

  11. Separation of tritium from gaseous and aqueous effluent systems

    International Nuclear Information System (INIS)

    Kobisk, E.H.

    1977-01-01

    Removal or reduction of tritium content in a wide variety of effluent streams has been extensively studied in the United States. This paper specifically reviews three processes involving tritium separation in the gaseous phase and the aqueous phase. Diffusion through a selective Pd-25Ag alloy membrane at temperatures up to 600 0 C and at pressures up to 700 kg/cm 2 has resulted in successful separation of hydrogen-deuterium mixtures with an associated separation factor of 1.65 (and gives a calculated separation factor for hydrogen-tritium mixtures of 2.0). Use of a single palladium bipolar membrane in an electrolysis system has been found to yield a hydrogen-deuterium separation factor of 4 and a hydrogen-tritium factor of 6 to 11 without the production of gaseous hydrogen. Finally, countercurrent catalytic exchange between tritium-containing hydrogen gas and water has yielded a separation factor of 6.3. The specific advantages of each of these systems will be discussed in terms of their potential applications. In all cases, further investigations are necessary to scale the systems to handle large quantities of feed material in a continuous mode and to minimize energy requirements. Such separative systems must necessarily be cascaded to yield gaseous or aqueous product streams suitable for recycling to the tritium producing systems, for storage or for discharge to the environment. (orig./HP) [de

  12. Design of a PWR gaseous effluent treatment system combining delay-storage vessels, volume-reduction and activated-charcoal beds

    International Nuclear Information System (INIS)

    Nuyt, G.; Glibert, R.; Lahaye, J.P.

    1986-01-01

    The usual technique for the treatment of gaseous effluents is to store them in radioactive decay tanks and to carry out a range of operations such as recycling, volume-reduction and discharge. Although presenting undeniable advantages, this technique has a number of weaknesses which have become apparent with experience. This paper describes and analyses a system designed to alleviate these difficulties and to permit greater flexibility in gaseous effluent treatment, especially for power stations in the load-following mode of operation, by means of a combination of storage techniques and retention of short-lived isotopes in activated charcoal beds. The attractiveness of the proposed system is apparent from an analysis of operational, maintenance, safety and cost aspects. (author)

  13. Calculation of releases of radioactive materials in gaseous and liquid effluents from boiling water reactors (BWR-GALE Code)

    International Nuclear Information System (INIS)

    Bangart, R.L.; Bell, L.G.; Boegli, J.S.; Burke, W.C.; Lee, J.Y.; Minns, J.L.; Stoddart, P.G.; Weller, R.A.; Collins, J.T.

    1978-12-01

    The calculational procedures described in the report reflect current NRC staff practice. The methods described will be used in the evaluation of applications for construction permits and operating licenses docketed after January 1, 1979, until this NUREG is revised as a result of additional staff review. The BWR-GALE (Boiling Water Reactor Gaseous and Liquid Effluents) Code is a computerized mathematical model for calculating the release of radioactive material in gaseous and liquid effluents from boiling water reactors (BWRs). The calculations are based on data generated from operating reactors, field tests, laboratory tests, and plant-specific design considerations incorporated to reduce the quantity of radioactive materials that may be released to the environment

  14. A radioactive noble gas quantitative analysis of gaseous effluents from NPP

    International Nuclear Information System (INIS)

    Yanev, Y.; Georgiev, K.; Mavrodiev, V.; Kikarin, B.

    1993-01-01

    The radioactive isotopes of argon, krypton and xenon comprise a substantial part of the gaseous emission of a NPP. A quantitative determination of their specific activity in the controlled area and the gaseous effluents requires a special sampling technique, as well as measurement method. The zeolites and the activated charcoals have a differentiated behaviour towards radioisotopes of argon, krypton and xenon. The isotope fractionation is often a problem, especially with argon and xenon. Some additional difficulties arise due to the irreproductibility of temperature and atmospheric moisture. The present paper describes a method for a spectrometric determination of radioactive noble gases after the cryogenic sampling developed at the Radiochemical laboratory of the Sofia University. The quality control of the method, as well as some special difficulties in its performing are discussed. The estimated minimum detectable activity is 5-10 Bq/m 3 for radioactive noble gases with half-life > 1 hour and sampling time for (resp. gamma-spectrometry) 1 hour. (author)

  15. Preliminary evaluation of the gaseous effluent sampling and monitoring systems at the 291-Z-1 and 296-Z-3 stacks

    International Nuclear Information System (INIS)

    Schwendiman, L.C.; Glissmeyer, J.A.

    1992-04-01

    The 291-Z-1 and 296-Z-3 stack effluent particulate sampling and monitoring systems are being evaluated for compliance with Atlantic Richfield Hanford Company's Interim Criteria for such systems. This evaluation is part of a study by Battelle-Northwest of gaseous effluent sampling systems in ARHCO facilities. This letter report presents a preliminary evaluation of the mentioned facilities and the indicated improvements needed to meet the Interim Criteria so that conceptual design work for improved systems can be initiated. There is currently underway a detailed study at the two stacks including a series of sampling experiments, the findings of which will not be included in this report. The gaseous effluent sampling system at the 291-Z-1 and 296-Z-3 stacks are very dissimilar and will be treated in separate sections of this report. The discussions for each sampling system will include a brief description and a preliminary evaluation of the systems

  16. Calculation of releases of radioactive materials in gaseous effluents from nuclear-powered merchant ships (NMS-GEFF code)

    International Nuclear Information System (INIS)

    Cardile, F.P.; Bangart, R.L.; Collins, J.T.

    1978-06-01

    The Intergovernmental Maritime Consultative Organization IMCO) is currently preparing guidelines concerning the safety of nuclear-powered merchant ships. An important aspect of these guidelines is the determination of the releases of radioactive material in effluents from these ships and the control exercised by the ships over these releases. To provide a method for the determination of these releases, the NRC staff has developed a computerized model, the NMS-GEFF Code, which is described in the following chapters. The NMS-GEFF Code calculates releases of radioactive material in gaseous effluents for nuclear-powered merchant ships using pressurized water reactors

  17. Test of active coal capacity for retaining gaseous effluents contaminated by 131 I

    International Nuclear Information System (INIS)

    Campeanu, Catalina; Cruceru, Madalina; Neacsu, Elena

    1999-01-01

    The aim of this paper is to test the retaining capacity of the active coal of the filters for gaseous effluents contaminated by 131 I. The active coal filters are design for equipping ventilation installations of nuclear plants in which radioactive iodine and combination of it were produced and handled. Such active coal filters are provided also to sorbonnes for radiochemical and physical handling of radioactive iodine. Testing the retaining capacity of active coal for filters is an obvious step, particularly, when the material was stored long time after preparation

  18. Evaluation of the use of activated carbon for the filtration of gaseous effluents generated in the production of the radiopharmaceutical FDG-18F

    International Nuclear Information System (INIS)

    Cunha, R.S.; Goulart, A.S.; Flores, M.R.; Saibt, M.

    2017-01-01

    Gaseous rejects generated in the production of FDG- 18 F are produced mainly during the irradiation of the enriched water (H2O 18 ) within the niobium / target body at the cyclotron accelerator and during the process of FDG- 18 F synthesis in the synthesizer modules within the cell hot. In order to reduce the levels of gaseous effluents emitted, activated carbon filters are used in the exhaust system. These have the ability to adsorb the 18 F gaseous molecules generated in the synthesis. This work aims to quantify the efficiency of the activated carbon filters in relation to the dose rate before and after the passage of the gases through the filtration system. To quantify the values in the exhaust system, two radiation detectors were used, in the equivalent dose rate mode in μSv/h. To evaluate the values obtained, graphs of the levels before and after the filtration system were generated. These graphs were compared to each other, relating the values found. The generated graphs showed a high efficiency in the filtration of gaseous effluents. Several dose rate peaks are presented in the exhaust system during FDG- 18 F synthesis, however after the passage of the gases through the filters these peaks become values very close to the Background values

  19. Studies for improvement of regulatory control on the radioactive effluent released from nuclear facilities

    International Nuclear Information System (INIS)

    Cheong, Jae Hak; Park, H. M.; Song, M. C.; Lee, K. H.; Jang, J. K.; Chun, J. K.; Jeong, K. H.

    2005-05-01

    This report contains the second-year results of the research project titled 'Studies for Improvement of Regulatory Control on the Radioactive Effluent Released from Nuclear Facilities' and mainly provides technical and strategic approaches to improve performance of regulatory control on the gaseous effluent released from domestic nuclear facilities. The main result contained here includes overview and technical bases of radioactive gaseous effluent control (Chapter 1), reconsideration of the sensitivity requirements for measurement of radioactivity in gaseous effluent sample (Chapter 2), uncertainty analysis of the calculated radioactivity in gaseous effluent (Chapter 3), and improvement of quantification method of noble gas releases (Chapter 4). In addition, analysis of the impact due to combined sampling of particulate from multiple release points (Chapter 5), comparison of domestic nuclear reactors gaseous effluent data to foreign PWRs (Chapter 6), standardized sampling technique for collection of gaseous tritium (Chapter 7), and application of Xe-133 equivalent concept to gaseous effluent control (Chapter 8) are also provided. As a whole, this report provides a generic approach to improve the performance of regulatory control on the gaseous effluent. Therefore, actual enforcement of the recommendations should be preceded by establishment of a series of action plans reflecting on the site- and facility-specific design and operational features

  20. Order of 4 august 1989 on licensing the release of gaseous radioactive effluents by the Cattenom nuclear production centre (units 3 and 4)

    International Nuclear Information System (INIS)

    1989-08-01

    This Order fixes the conditions and limits of authorised releases of gaseous radioactive effluents from Units 3 and 4 of the Cattenom nuclear power plant. It specifies these are maximum limits, below which the radioactive releases should be as low as possible [fr

  1. Radioactive clearance discharge of effluent from nuclear and radiation facilities

    International Nuclear Information System (INIS)

    Liu Xinhua; Xu Chunyan

    2013-01-01

    On the basis of the basic concepts of radiation safety management system exemption, exclusion and clearance, we expound that the general industrial gaseous and liquid effluent discharges are exempted or excluded, gaseous and liquid effluent discharged from nuclear and radiation facilities are clearance, and non-radioactive. The main purpose of this paper is to clarify the concepts, reach a consensus that the gaseous and liquid effluent discharged from nuclear and radiation facilities are non-radioactive and have no hazard to human health and natural environment. (authors)

  2. Source terms for airborne effluents

    International Nuclear Information System (INIS)

    Blomeke, J.O.; Perona, J.J.

    1976-01-01

    The origin and nature of fuel cycle wastes are discussed with regard to high-level wastes, cladding, noble gases, iodine, tritium, 14 C, low-level and intermediate-level transuranic wastes, non-transuranic wastes, and ore tailings. The current practice for gaseous effluent treatment is described for light water reactors and high-temperature gas-cooled reactors. Other topics discussed are projections of nuclear power generation; projected accumulation of gaseous wastes; the impact of nuclear fuel cycle centers; and global buildup of airborne effluents

  3. An improved calibration technique for measurement of 41Ar activity in gaseous effluents

    International Nuclear Information System (INIS)

    Jose, M.T.; Raghunath, V.M.

    1992-01-01

    One of the methods used generally for the calibration of a gaseous effluent monitoring system is to estimate the efficiency of the detector system with a point source of 22 Na. The uncertainty in this method is the assumption that a point source kept at a distance from the detector and a volume source nearer the detector will have the same efficiency. To overcome this problem, a technique of using 22 Na in liquid form has been standardised. The uncertainties in the strength of the liquid source is avoided by proper intercomparison of the same with a reference standard traceable to a primary standard. The NaI system has been calibrated for estimating the 41 Ar activity from the peak area counts in the MCA and SCA systems respectively. (author). 1 ref., 1 tab

  4. Sampling and monitoring of carbon-14 in gaseous effluents from nuclear facilities - a literature survey

    International Nuclear Information System (INIS)

    Snellman, M.

    1988-12-01

    C-14 compounds produced in the coolant may be released mainly together with off-gas and waste water from the coolant purification and treatment system. In reactors the release of C-14 will occur mainly in gaseous effluents and only a few percent in liquid effluents. Reported releases from BWRs range from 260 to 670 GBq/GW(e) x year and from 90 to 430 GBq/GW(e) x year for PWRs. At BWRs the condenser air ejector contributes the main inplant release pathway, whereas in PWRs the off-gas treatment vents are the main pathway for C-14 release. C-14 sampling methods depend generally on the C-14 being in the form of CO 2 . The off-gas discharges from BWRs are mainly in the form of CO 2 whereas in PWRs a major fraction of the released C-14 is in the form of hydrocarbons or carbon monoxide (generally 80-100%). Sampling systems in PWRs should therefore be equipped with a catalytic oxidizer to convert all C-14 to CO 2 before trapping. The purpose of this study is to provide information on the techniques available for sampling and monitoring C-14

  5. An estimation of exposure from gaseous and volatile radioactive effluents released from EWA reactor between 1971 and 1975

    International Nuclear Information System (INIS)

    Filipiak, B.; Nowicki, K.

    1979-01-01

    The paper gives an estimation of radiation doses for individuals due to gaseous radioactive effluents released from EWA reactor between 1971 and 1975. The doses were estimated for three organs, three groups of people: adults, teenagers and children and for three of the most important exposure paths: the external radiation from a passing cloud, inhalation and from milk ingestion. The results of calculations indicate that the radiation doses received by individuals living in the vicinity of EWA reactor were much below the limit doses or those due to the background radiation. (author)

  6. Decree No 74-945 of 6 November 1974 concerning gaseous radioactive effluent releases from large nuclear installations and nuclear installations located on the same site

    International Nuclear Information System (INIS)

    1974-01-01

    This Decree prescribes the licensing for the release of gaseous wastes from nuclear installations as well as the technical supervision of such operations. It does not apply to the transport of radioactive effluents which is governed by the regulations on the transport of dangerous goods. (NEA) [fr

  7. Control of the aerozol-gaseous effluents at the Novovoronezh NPP and study of the environmental impact

    International Nuclear Information System (INIS)

    Baranov, M.A.; Sedov, V.K.

    1981-01-01

    The system of dosimetric control of environment in the vicinity of the Novovoronezh NPP (NVNPP) is described. Annual values of gaseous- aerozol radioactive effluents (including their isotope composition) during the operation of the two NVNPP WWER-440 reactors since 1972 up to 1979 are presented. Concentrations of radioactive substances (total and separately by 30 Sr and 137 Cs isotopes) in the air as well as dose rates of the population in the control region of the NV NPP from 1965 up to 1979 are given. It is concluded that essential statistical material characterizing the environment state that testifies to the absence of harmful NPP effect on the environment objects and population is accumulated during 15 year NVNPP operation [ru

  8. Continuous monitoring of gaseous effluents

    International Nuclear Information System (INIS)

    Velasco, A.; Giraut, H.; Prado, M.; Bonino, A.D.

    1990-01-01

    The system allows to continuously determine the radioactive materials discharge (iodine, noble gases and aerosols) to the environment. It consists in compelling, by a pump, a known and fixed fraction of the total flow and preserving the aerosols by a filter. The gas -now free from aerosols- traverses an activated carbon filter which keeps the iodine; after being free from aerosols and iodine, the effluent traverses a measurement chambers for noble gases which has a scintillator. (Author) [es

  9. Decision no 2009-DC-0157 of the 15. of September 2009 by the Nuclear Safety Authority specifying the limits of releases in the environment of liquid and gaseous effluents of the base nuclear installation n. 29 operated by the CIS Bio International on the district of Saclay (Essonne department)

    International Nuclear Information System (INIS)

    2009-01-01

    This document contains references to the different legal and official documents (codes, orders, minister's opinion, public surveys, administrative authorizations, local community opinion) at the root of this specification of limits related to releases in the environment of liquid and gaseous effluents of a base nuclear installation. Tables present the limits for radioactive liquid effluents (iodine, rare earths, and other beta and gamma emitters) and the maximum admitted concentrations for gaseous chemical effluents (SO 2 , H 2 S, VOCs)

  10. Radioactivity in gaseous waste discharged from the separations facilities during 1978

    International Nuclear Information System (INIS)

    Anderson, J.D.; Poremba, B.E.

    1979-01-01

    This document is issued quarterly for the purpose of summarizing the radioactive gaseous wastes that are discharged from the facilities of the Rockwell Hanford Operations. Data on alpha and beta emissions during 1978 are presented where relevant to the gaseous effluent. Emission data are not included on gaseous wastes produced within the 200 Areas by other Hanford contractors

  11. Monitoring of noble gas radioisotopes in nuclear power plant effluents

    International Nuclear Information System (INIS)

    Kabat, M.J.

    1985-01-01

    Monitoring of gaseous radionuclides in the effluents of nuclear facilities is an essential requirement in effluent management programs. Since there is no practical way of removing noble gas radioisotopes from air at release pathways, their accurate monitoring is essential for providing appropriate environmental protection. Emitted γ dose-rate is the limiting factor for concentration-time integral of noble gas in gaseous effluents of reactor facilities. The external exposure to the public from a semi-infinite cloud is directly proportional to both the noble gas isotope concentration and the integrated γ energy per disintegration. Both can be directly measured in gaseous effluent pathways with a suitable detector. The capability of NaI(T1), CaF 2 (Eu) and plastic scintillation detectors to measure the γ-Ci.MeV content of noble gas releases was experimentally evaluated. The combination of CaF 2 (Eu) detector in a pressurized through-flow chamber, with a charge integrating scaler well complied with both γ energy response and detection sensitivity requirements. Noble gas source terms and effluent monitoring criteria are discussed, theoretical and experimental results are presented and a practical, on-line noble gas monitoring system is described

  12. A study on the diffusion of gaseous radioactive effluents based on the statistical method

    International Nuclear Information System (INIS)

    Na, Man Gyun; Lee, Goung Jin

    1998-01-01

    A diffusion model of radioactive gaseous effluents is improved to apply for domestic nuclear power plants. Up to now, XOQDOQ computer code package developed by U. S NRC has been used for the assessment of radioactive plume dispersion by normal operation of domestic nuclear power plants. XOQDOQ adopts the straight-line Gaussian plume model which was basically derived for the plane terrain. However, since there are so many mountains in Korea, the several shortcomings of XOQDOQ are improved to consider the complex terrain effects. In this work, wind direction change is considered by modifying the wind rose frequency using meteorological data of the local weather stations. In addition, an effective height correction model, a plume reduction model due to plume penetration into mountain, and a wet deposition model are adopted for more realistic assessments. The proposed methodology is implemented in Yonggwang nuclear power plants, and can be used for other domestic nuclear power plants

  13. Radiation treatment of gaseous and liquid effluents for contaminant removal. Proceedings of a technical meeting

    International Nuclear Information System (INIS)

    2005-12-01

    The Technical Meeting on Radiation Processing of Gaseous and Liquid Effluents conducted in Sofia, Bulgaria, 7-10 September 2004, discussed and evaluated issues related to the status and future trends in radiation application for environmental protection. Five experts from Bulgaria, India, the Republic of Korea, Poland, and the United States of America were invited to provide their experiences in this field. Twenty cost-free participants and observers - from Bulgaria, India, Lithuania, Poland and Ukraine -joined the meeting, and 15 papers in total were presented. Research and development in radiation processing of gaseous and liquid effluents is undertaken in three fields: electron beam flue gas treatment (SO x and NO x removal), wastewater purification and sewage sludge sterilization. Wastewater or sludge treatment and flue gas purification all differ from technological points of view, but they are common services and applications of environmental radiation technology applications, based mostly on electron accelerators. The technical meeting discussed new development in the field of radiation applications in environmental service, especially the status and prospects of radiation processing of gaseous and liquid effluents. Progress in the field of electron accelerators and gamma sources is crucial for routine application of the technology. Cost reduction and improvement of technical reliability are substantial especially for high power of accelerators and high activity of the sources needed for environmental applications. Environmental applications were carefully reviewed in accordance with the existing regulations and state of the art knowledge. The comparison with conventional commercial technologies was addressed as well. In flue gas treatment, applicability of the technology using different fossil fuels (coal, lignite, oil, etc.) was reviewed. The elaborated materials cover the technical and economical evaluation of the technologies. The possible applications of

  14. Portsmouth Gaseous Diffusion Plant environmental monitoring report for calendar year 1981

    International Nuclear Information System (INIS)

    Acox, T.A.; Anderson, R.E.; Hary, L.F.; Klein, L.S.; Vausher, A.L.

    1982-04-01

    At the Portsmouth Gaseous Diffusion Plant all effluent streams are sampled regularly and analyzed to assess compliance with applicable environmental standards. Radioactivity is measured in air, water, food, soil, and sediments; and radiation doses to the public are calculated. All public radiation doses from process effluents are well within Department of Energy and US EPA standards. Non-radioactive effluents either presently comply with federal standards or will comply upon completion of planned projects. The environmental impact of effluents from cleaning and decontamination operations has been reduced through flow reduction and improved chemical treatment. CY-1981 was the first full year under a new National Pollutant Discharge. Elimination System (NPDES) permit for liquid effluents; compliance with the permit's discharge limits did not present any significant problems. Engineering is proceeding on projects to be constructed through 1985 to further reduce the impact of liquid effluents. A new licensed sanitary landfill utilizing the area fill method went into operation in July 1981. Although neither the State of Ohio nor the federal government has established standards for fluoride in the atmosphere or in vegetation, fluorides are monitored because they are used extensively in the gaseous diffusion process

  15. Process for exchanging hydrogen isotopes between gaseous hydrogen and water

    International Nuclear Information System (INIS)

    Hindin, S.G.; Roberts, G.W.

    1977-01-01

    A process is described for exchanging isotopes (particularly tritium) between water and gaseous hydrogen. Isotope depleted gaseous hydrogen and water containing a hydrogen isotope are introduced into the vapour phase in a first reaction area. The steam and gaseous hydrogen are brought into contact with a supported metal catalyst in this area in a parallel flow at a temperature range of around 225 and 300 0 C. An effluent flow comprising a mixture of isotope enriched gaseous hydrogen and depleted steam is evacuated from this area and the steam condensed into liquid water [fr

  16. Paducah Gaseous Diffusion Plant Annual Site Environmental Report for 1993

    International Nuclear Information System (INIS)

    1994-10-01

    The purpose of this document is to summarize effluent monitoring and environmental surveillance results and compliance with environmental laws, regulations, and orders at the Paducah Gaseous Diffusion Plant (PGDP). Environmental monitoring at PGDP consists of two major activities: effluent monitoring and environmental surveillance. Effluent monitoring is direct measurement or the collection and analysis of samples of liquid and gaseous discharges to the environment. Environmental surveillance is direct measurement or the collection and analysis of samples of air, water, soil, foodstuff, biota, and other media. Environmental monitoring is performed to characterize and quantify contaminants, assess radiation exposures of members of the public, demonstrate compliance with applicable standards and permit requirements, and detect and assess the effects (if any) on the local environment. Multiple samples are collected throughout the year and are analyzed for radioactivity, chemical content, and various physical attributes

  17. Detection of gaseous fission products in water - a method of monitoring fuel sheathing failures

    Energy Technology Data Exchange (ETDEWEB)

    Tunnicliffe, P. R.; Whittier, A. C.

    1959-05-15

    The gaseous activities stripped from samples of effluent coolant from the NRU fuel elements tested in the central thimble of the NRX reactor (NRU loop) and from the NRX main effluent have been investigated. The activities obtained from the NRU loop can be attributed to gaseous fission products only. Design data have been obtained for a 'Gaseous Fission Product Monitor' to be installed for use with the NRU reactor. It is expected that this monitor will have high sensitivity to activity indicative of an incipient fuel element sheath failure. No qualitative determination of the various gaseous activities obtained from the NRX effluent has been made. A strong component of 25 {+-}1 seconds half-life is not consistent with O-19. Limited information concerning sheath failures in NRX was obtained. Of six failures observed in parallel with the installed delayed neutron monitors, three of these gave pre-warnings and in each case the gaseous fission product monitor showed a substantially greater sensitivity. An experiment in which small samples of uranium, inserted into the NRX reactor, could be exposed at will to a stream of water showed the behaviour of the two types of monitors to be similar. However, a number of signals were detected only by the gaseous fission product monitor. These can be attributed to its sensitivity to relatively long lived fission products. (author)

  18. Method and apparatus for treating gaseous effluents from waste treatment systems

    Science.gov (United States)

    Flannery, Philip A.; Kujawa, Stephan T.

    2000-01-01

    Effluents from a waste treatment operation are incinerated and oxidized by passing the gases through an inductively coupled plasmas arc torch. The effluents are transformed into plasma within the torch. At extremely high plasma temperatures, the effluents quickly oxidize. The process results in high temperature oxidation of the gases without addition of any mass flow for introduction of energy.

  19. Portsmouth gaseous diffusion plant environmental monitoring report for calendar year 1975

    International Nuclear Information System (INIS)

    Martin, W.E.; Netzer, W.D.

    1976-01-01

    At the Portsmouth Gaseous Diffusion Plant the ambient atmosphere and all effluent streams are sampled and analyzed regularly for conformance to applicable environmental standards. Although neither the State of Ohio nor the federal government has established standards for fluorides in the ambient atmosphere or in vegetation, these parameters also are monitored because fluoride compounds are used extensively in the gaseous diffusion process. Radioactivity is measured in air, water, food, soil, and sediments; and radiation doses are calculated for the public. All public radiation doses are well within federal standards. Non-radioactive effluent parameters either comply with federal standards, or there are projects planned to allow compliance. A disposal facility to remove chromium from recirculating cooling water blowdown will begin operation in June 1976. Also, pH adjustment facilities for liquid effluents and electrostatic precipitators for a coal-fired steam plant are planned for the near future

  20. Process and system for removing sulfur from sulfur-containing gaseous streams

    Science.gov (United States)

    Basu, Arunabha; Meyer, Howard S.; Lynn, Scott; Leppin, Dennis; Wangerow, James R.

    2012-08-14

    A multi-stage UCSRP process and system for removal of sulfur from a gaseous stream in which the gaseous stream, which contains a first amount of H.sub.2S, is provided to a first stage UCSRP reactor vessel operating in an excess SO.sub.2 mode at a first amount of SO.sub.2, producing an effluent gas having a reduced amount of SO.sub.2, and in which the effluent gas is provided to a second stage UCSRP reactor vessel operating in an excess H.sub.2S mode, producing a product gas having an amount of H.sub.2S less than said first amount of H.sub.2S.

  1. Retention of gaseous isotopes

    International Nuclear Information System (INIS)

    Yarbro, O.O.; Mailen, J.C.; Stephenson, M.J.

    1977-01-01

    Retention of gaseous fission products during fuel reprocessing has, in the past, been limited to a modest retention of 131 I when processing fuels decayed less than about 180 days. The projected rapid growth of the nuclear power industry along with a desire to minimize environmental effects is leading to the reassessment of requirements for retention of gaseous fission products, including 131 I, 129 I, 85 Kr, 3 H, and 14 C. Starting in the late 1960s, a significant part of the LMFBR reprocessing development program has been devoted to understanding the behavior of gaseous fission products in plant process and effluent streams and the development of advanced systems for their removal. Systems for iodine control include methods for evolving up to 99% of the iodine from dissolver solutions to minimize its introduction and distribution throughout downstream equipment. An aqueous scrubbing system (Iodox) using 20 M HNO 3 as the scrubbing media effectively removes all significant iodine forms from off-gas streams while handling the kilogram quantities of iodine present in head-end and dissolver off-gas streams. Silver zeolite is very effective for removing iodine forms at low concentration from the larger-volume plant off-gas streams. Removal of iodine from plant liquid effluents by solid sorbents either prior to or following final vaporization appears feasible. Krypton is effectively released during dissolution and can be removed from the relatively small volume head-end and dissolver off-gas stream. Two methods appear applicable for removal and concentration of krypton: (1) selective absorption in fluorocarbons, and (2) cryogenic absorption in liquid nitrogen. The fluorocarbon absorption process appears to be rather tolerant of the normal contaminants (H 2 O, CO 2 , NOsub(x), and organics) present in typical reprocessing plant off-gas whereas the cryogenic system requires an extensive feed gas pretreatment system. Retention of tritium in a reprocessing plant is

  2. Methodology of adjustment point in the post treatment of gaseous effluents; Metodologia del punto de ajuste en el post tratamiento de efluentes gaseosos

    Energy Technology Data Exchange (ETDEWEB)

    Vizuet G, J.; Molina, G. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)]. e-mail: jvg@nuclear.inin.mx

    2005-07-01

    The methodology to determine the adjustment points of the monitoring system of gaseous discharges is based on the stipulations of the 10CFR20, which are expressed in terms of limit concentrations for the outstanding radionuclides, and of dose limits for the individuals members of the public. Besides the points of liberation properly said, like they are the chimneys of the reactor buildings and of turbine, the points of adjustment of the monitoring instrumentation that watches in real time the discharge of the Treatment system of output gases, to the HVAC of the waste building; they also undergo to the same methodology, with the approaches previously described. (Author)

  3. Gaseous radioactive effluent restrictions, measurement, and minimization at a PET/cyclotron facility

    International Nuclear Information System (INIS)

    Plascjak, P.S.; Kim, K.K.; Googins, S.W.; Meyer, W.C. Jr.

    1993-01-01

    In the US, restrictions on the release of radioactive effluents from PET (positron emission tomography)/cyclotron facilities are typically imposed by State regulatory agencies and may be based on various methodologies and limits published by numerous agencies. This work presents suitable effluent concentration limits for various chemical forms of radioisotopes routinely produced in PET/cyclotron facilities. They were determined by application of metabolic models defined by ICRP 53 and ICRP 26/30 which will result in compliance with effective dose equivalent limits of 100 mrem per year at the release point. The NIH Cyclotron Facility effluent air monitoring system, environmental dosimetry program, and simple, effective systems for radioactive effluent minimization are also described. (orig.)

  4. Determination of Kr-85 in environmental samples and gaseous effluents from nuclear industries using the standard method; Aplicacion del metodo de concentracion separacion y medida radiactiva por centelleo liquido de Kr-85 en muestras ambientales y en efluentes gaseosos de la industria nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Heras, M c; Perez, M M

    1983-07-01

    The determination of the Kr-85 activity in environmental samples and gaseous effluents from Spanish Nuclear Power Stations is described. The method employed has been published elsewhere. The determinations has been carried out in environmental samples token at JEN Laboratories (Madrid) and the Nuclear Power Stations, Jose Cabrera (Zorita), Garona and Vandellos. Also samples of gaseous effluents of the three plants has been analyzed. Values of the Kr-85 environmental background activity in the Almaraz Nuclear Power Stations, has been determined, before the beginning of its nuclear activity. In this paper the sampling equipment used is described and the values found of Kr-85 activity in all the samples in given. (Author) 29 refs.

  5. Tritium effluent removal system

    International Nuclear Information System (INIS)

    Lamberger, P.H.; Gibbs, G.E.

    1978-01-01

    An air detritiation system has been developed and is in routine use for removing tritium and tritiated compounds from glovebox effluent streams before they are released to the atmosphere. The system is also used, in combination with temporary enclosures, to contain and decontaminate airborne releases resulting from the opening of tritium containment systems during maintenance and repair operations. This detritiation system, which services all the tritium handling areas at Mound Facility, has played an important role in reducing effluents and maintaining them at 2 percent of the level of 8 y ago. The system has a capacity of 1.7 m 3 /min and has operated around the clock for several years. A refrigerated in-line filtration system removes water, mercury, or pump oil and other organics from gaseous waste streams. The filtered waste stream is then heated and passed through two different types of oxidizing beds; the resulting tritiated water is collected on molecular sieve dryer beds. Liquids obtained from regenerating the dryers and from the refrigerated filtration system are collected and transferred to a waste solidification and packaging station. Component redundancy and by-pass capabilities ensure uninterrupted system operation during maintenance. When processing capacity is exceeded, an evacuated storage tank of 45 m 3 is automatically opened to the inlet side of the system. The gaseous effluent from the system is monitored for tritium content and recycled or released directly to the stack. The average release is less than 1 Ci/day. The tritium effluent can be reduced by isotopically swamping the tritium; this is accomplished by adding hydrogen prior to the oxidizer beds, or by adding water to the stream between the two final dryer beds

  6. Assessment of derived emission limits for radioactive effluents resulted from the decommissioning activities of the VVR-S nuclear research reactor

    International Nuclear Information System (INIS)

    Tuca, C.; Stochioiu, A.; Sahagia, M.; Gurau, D.; Dragusin, M.

    2015-01-01

    This paper presents complex studies on establishment of derived emission limits for potential radionuclides emitted as gaseous and liquid effluents, during the decommissioning activities (2nd and 3rd phases) of a nuclear research reactor, cooled and moderated with distilled water, type VVR-S, owned by the IFIN-HH. In the present paper there are described: the analysis methods and equipment used, the methodologies for calculating doses and the Derived Emission Limits (DEL), the experimentally measured activities of the representative radionuclides found in gaseous and liquid effluents resulted from decommissioning activities, as well as the effective derived limits of liquid and gaseous effluents, applying the calculation methodologies, specific to critical categories of exposed subjects. A constraint effective dose limit for a person from the critical group of 50 μSv/year was considered in calculations. From the comparison of the two series of values, measured released activities and DELs, there has been concluded that for the gaseous effluents they comply with the DELs, while in the case of liquid effluents they are higher and consequently they must be treated as liquid radioactive wastes. - Highlights: • The DELs for gaseous and liquid effluents in decommissioning were studied. • The impact on the environment and critical group was assessed. • Gamma-ray spectrometry was used to determine the radionuclide composition. • Based on the dosimetry models, the values of conservative DELs were calculated. • The DELs are compliant for gases, not for liquids; require the treatment as rad-waste

  7. Radioactive effluents, Portsmouth Gaseous Diffusion Plant, calendar year 1982

    International Nuclear Information System (INIS)

    Acox, T.A.; Hary, L.F.; Klein, L.S.

    1983-03-01

    Radioactive discharges from the Portsmouth Gaseous Diffusion Plant are discussed and tabulated. Tables indicate both the location of the discharge and the nuclides discharged. All discharges for 1982 are well below the Radioactive Concentration Guide limits specified in DOE Order 5480.1, Chapter XI. 1 figure

  8. The determination of Pu-241 by liquid scintillation counting in gaseous effluents of an incineration facility, FERAB, and the Karlsruhe Nuclear Reprocessing Plant, WAK

    International Nuclear Information System (INIS)

    Godoy, J.M.; Schuettelkopf, H.

    1983-03-01

    Although the concentration of Pu-241 in nuclear fuel to be reprocessed is high, there are only few results published about the emission of Pu-241 with gaseous and liquid effluents. Nearly no information is available, too, about the environmental contamination of nuclear installations by Pu-241. Therefore a procedure was developed to measure Pu-241 by liquid scintillation counting. Sample preparation was performed by electroplating of plutonium on stainless steel planchets. To correct the selfabsorption the linear dependence of counting efficiency in the liquid scintillation counter and the resolution in the α-spectrometer was used. (orig./HP) [de

  9. Sensitivity Analysis of Input Parameters for the Dose Assessment from Gaseous Effluents due to the Normal Operation of Jordan Research and Training Reactor

    International Nuclear Information System (INIS)

    Kim, Sukhoon; Lee, Seunghee; Kim, Juyoul; Kim, Juyub; Han, Moonhee

    2015-01-01

    In this study, therefore, the sensitivity analysis of input variables for the dose assessment was performed for reviewing the effect of each parameter on the result after determining the type and range of parameters that could affect the exposure dose of the public. (Since JRTR will be operated by the concept of 'no liquid discharge,' the input parameters used for calculation of dose due to liquid effluents are not considered in the sensitivity analysis.) In this paper, the sensitivity analysis of input parameters for the dose assessment in the vicinity of the site boundary due to gaseous effluents was performed for a total of thirty-five (35) cases. And, detailed results for the input variables that have an significant effect are shown in Figures 1 through 7, respectively. For preparing a R-ER for the operating license of the JRTR, these results will be updated by the additional information and could be applied to predicting the variation trend of the exposure dose in the process of updating the input parameters for the dose assessment reflecting the characteristics of the JRTR site

  10. Technical Orders of 10 August 1976 on the limits and procedures applicable to radioactive effluent discharges from nuclear installations

    International Nuclear Information System (INIS)

    1976-01-01

    Seven technical Orders by the competent Ministers (mainly the Ministers of Health, of Industry and Research, of the Quality of Life) lay down the procedures, conditions and limits applicable to gaseous and liquid radioactive effluent discharges from nuclear installations. These Orders of 10 August were published on 12 September 1976 in the Official French Gazette and were made in implementation of the Decree of 6 November 1974 on gaseous radioactive effluent discharges from nuclear installations and the Decree of 31 December 1974 on liquid radioactive effluent discharges from nuclear installations. Apart from the general rules for setting limits and methods for effluent discharges, they specify the measures for environmental monitoring and for control by the Central Service for Protection against Ionizing Radiations. Certain of them contain the general rules for liquid or gaseous effluent discharges from all nuclear installations, while others lay down the rules proper to light water nuclear power plants. Other types of reactor ie. fast breeders are not yet subject to such regulations. (N.E.A.) [fr

  11. Order of the 10 january 2003 authorizing the national agency for the radioactive wastes management to follow the gaseous and liquid effluents release for the exploitation of the radioactive wastes storage center of the Manche

    International Nuclear Information System (INIS)

    2003-01-01

    This document, took out from the Official Journal, is the law text relative to the order of the 10 january 2003 authorizing the national agency for the radioactive wastes management to follow the gaseous and liquid effluents release for the exploitation of the radioactive wastes storage center of the Manche. (A.L.B.)

  12. Decision no 2010-DC-0188 by the Nuclear Safety Authority on the 7. of July 2010 specifying to Electricite de France-Societe Anonyme (EDF-SA) the limits of releases in the environment of liquid and gaseous effluents for the operation of Flamanville 1 (IBN n 108), Flamanville 2 (INB n 109) and Flamanville 3 (INB n 167) reactors

    International Nuclear Information System (INIS)

    2010-01-01

    This document contains references to the different legal and official documents (codes, orders, minister's opinion, public surveys, administrative authorizations, local community opinion) at the root of this specification of limits related to releases in the environment of liquid and gaseous effluents by the three Flamanville nuclear reactors operated by Electricite de France-Societe Anonyme (EDF-SA). Tables present the limits for different gaseous and liquid radioactive emissions (carbon 14, hydrogen 3, iodine, radioactive rare earths, and other beta and gamma emitters) from these different installations, but also the maximum admitted concentrations for gaseous chemical effluents (boric acid, hydrazine hydrate, morpholine, phosphates, nitrates, various metals, and so on). The limits for thermal releases are also specified

  13. Effluents and releases of tritium from Novo-Voronezh-5 reactor

    International Nuclear Information System (INIS)

    Babenko, A.G.; Mekhedov, B.N.; Podporinova, L.E.; Popov, S.V.; Shalin, A.N.

    1990-01-01

    Results of systematic measurements of tritium concentration within technological systems of reactor of Novo-Voronezh NPP conducted to evaluate tritium effluents and releases and radiation doses to population from these effluents and releases are given. It is shown that 68% concerning tritium total amount were disposed into sewerage while 17% - through vent tube and 15% - with water and steam from secondary circuit systems. Standartized tritium effluents from WWER-1000 reactor for 5 year run constitute 15±1.9 GBq/MWxyear and it corresponds to mean value of effluents for foreign NPPs. Tritium concentration in the atmosphere constituted according to calculations (4.1-20)x10 -5 Bq/l. Conclusion is made about insignificant dose to population from tritium gaseous effluents. Detail study is necessary for dose connected with tritium contained in water effluents

  14. A database system for the control of radioactive effluents generated by the IPEN-CNEN/SP installations

    International Nuclear Information System (INIS)

    Maduar, M.F.

    1992-01-01

    A PC-compatible database system has been developed in order to optimize the control of liquid and gaseous effluents generated by the installations of IPEN-CNEN/SP. The system implements source-term generation, optimizes the discharge control of the effluents and allows several ways for the retrieval of data concerning to the effluents. (author)

  15. PWR-GALE, Radioactive Gaseous Release and Liquid Release from PWR

    International Nuclear Information System (INIS)

    Chandrasekaran, T.; Lee, J.Y.; Willis, C.A.

    1988-01-01

    1 - Description of program or function: The PWR-GALE (Boiling Water Reactor Gaseous and Liquid Effluents) Code is a computerized mathematical model for calculating the release of radioactive material in gaseous and liquid effluents from pressurized water reactors (PWRs). The calculations are based on data generated from operating reactors, field tests, laboratory tests, and plant-specific design considerations incorporated to reduce the quantity of radioactive materials that may be released to the environment. 2 - Method of solution: GALE calculates expected releases based on 1) standardized coolant activities derived from ANS Standards 18.1 Working Group recommendations, 2) release and transport mechanisms that result in the appearance of radioactive material in liquid and gaseous waste streams, 3) plant-specific design features used to reduce the quantities of radioactive materials ultimately released to the environs, and 4) information received on the operation of nuclear power plants. 3 - Restrictions on the complexity of the problem: The liquid release portion of GALE uses subroutines taken from the ORIGEN (CCC-217) to calculate radionuclide buildup and decay during collection, processing, and storage of liquid radwaste. Memory requirements for this part of the program are determined by the large nuclear data base accessed by these subroutines

  16. Controlled decomposition and oxidation: A treatment method for gaseous process effluents

    Science.gov (United States)

    Mckinley, Roger J. B., Sr.

    1990-01-01

    The safe disposal of effluent gases produced by the electronics industry deserves special attention. Due to the hazardous nature of many of the materials used, it is essential to control and treat the reactants and reactant by-products as they are exhausted from the process tool and prior to their release into the manufacturing facility's exhaust system and the atmosphere. Controlled decomposition and oxidation (CDO) is one method of treating effluent gases from thin film deposition processes. CDO equipment applications, field experience, and results of the use of CDO equipment and technological advances gained from the field experiences are discussed.

  17. Monitoring and removal of gaseous carbon-14 species

    International Nuclear Information System (INIS)

    Kabat, M.J.

    1979-01-01

    A simple and efficient method was developed for the monitoring of low level carbon-14 in nuclear power station areas and gaseous effluent. Gaseous carbon compounds (hydrocarbons and CO) are catalytically oxidized to CO 2 , which is then absorbed on solid Ca(OH) 2 at elevated temperatures. The 14 C collected is quantitatively liberated by thermal decomposition of CaCO 3 as CO 2 , which is either measured directly by flow-through detectors or absorbed in alkali hydroxide followed by liquid scintillation counting. The method can also be used for the removal of gaseous 14 C. The Ca 14 CO 3 can be immobilized in concrete for long term disposal. Ca(OH) 2 is an inexpensive absorber. It is selective for CO 2 and has high capacity and efficiency for its absorption and retention. A theoretical evaluation of thee optium conditions for CO 2 absorption and liberation is discussed and experimental investigations are described. There is good agreement between theoretical predictions and experimental findings

  18. Order of the 15. of September 2010 approving the decision no 2010-DC-0188 by the Nuclear Safety Authority on the 7. of July 2010 specifying to Electricite de France-Societe Anonyme (EDF-SA) the limits of releases in the environment of liquid and gaseous effluents for the operation of Flamanville 1 (INB n 108), Flamanville 2 (INB n 109) and Flamanville 3 (INB n 167) reactors

    International Nuclear Information System (INIS)

    2010-01-01

    This legal publication contains references to the different legal and official documents (codes, orders, minister's opinion, public surveys, administrative authorizations, local community opinion) at the root of this specification of limits related to releases in the environment of liquid and gaseous effluents by the three Flamanville nuclear reactors operated by Electricite de France-Societe Anonyme (EDF-SA). Tables present the limits for different gaseous and liquid radioactive emissions (carbon 14, hydrogen 3, iodine, radioactive rare earths, and other beta and gamma emitters) from these different installations, but also the maximum admitted concentrations for gaseous chemical effluents (boric acid, hydrazine hydrate, morpholine, phosphates, nitrates, various metals, and so on). The limits for thermal releases are also specified

  19. Reduction of releases of radioactive effluents from light-water-power-reactors in Japan

    International Nuclear Information System (INIS)

    Yoshida, Y.; Itakura, T.; Kanai, T.

    1977-01-01

    Japan Atomic Energy Commission established the dose objectives to the population around the light-water-reactors in May, 1975, based on the ''ALAP'' concept. These values are respectively, 5 mrems per year for total body and 15 mrems per year for thyroid of an individual in the critical group in the environs, due to both gaseous and liquid effluents from LWRs in one site. The present paper describes the implications of the dose objective values, control measures which have been adopted to reduce releases of radioactive materials and related technical developments in Japan. The main control measures for reduction of radioactive gaseous effluents are an installation of a charcoal gas holdup system for decay of noble gases and a supply of clean steam for the gland seal of a turbine in BWR, and a storage tank system allowing decay of noble gases in PWR. For liquid effluents are taken measures to re-use them as the primary coolant. Consequently, the amounts of radioactivity released to the environment from any LWR during normal operation have been maintained under the level to meet the above dose objective values. For research reactors, reduction of release of effluents has also been carried out in a similar way to LWRs. In order to establish the techniques applicable for further reduction, studies are being made on the control measures to reduce leakage of radioiodine, an apparatus for removal of krypton, the treatment of laundry waste and measures to remove the crud in the primary coolant. Presentation is also made on the energy-integrated gas monitor for gaseous effluent and systems of measuring γ dose from radioactive cloud descriminating from natural background, which have been developed for effective monitoring thus reduced environmental dose

  20. Treatment and processing of the effluents and wastes (other than fuel) produced by a 900 MWe nuclear power plant

    International Nuclear Information System (INIS)

    Giraud

    1983-01-01

    Effluents produced by a 900 MWe power plant, are of three sorts: gaseous, liquid and solid. According to their nature, effluents are either released or stored for decaying before being released to the atmosphere. The non-contaminated reactor coolant effluents are purified (filtration, gas stripping) and treated by evaporation for reuse. Depending upon their radioactive level, liquid waste is either treated by evaporation or discharged after filtration. Solid waste issuing from previous treatments (concentrates, resins, filters) is processed in concrete drums using an encapsulation process. The concrete drum provides biological self-protection consistent with the national and international regulations pertaining to the transport of radioactive substance. Finally, the various low-level radioactive solid waste collected throughout the plant, is compacted into metal drums. Annual estimates of the quantity of effluents (gaseous, liquid) released in the environment and the number of drums (concrete, metal) produced by the plant figure in the conclusion

  1. Dose apportionment using statistical modeling of the effluent release

    International Nuclear Information System (INIS)

    Datta, D.

    2011-01-01

    Nuclear power plants are always operated under the guidelines stipulated by the regulatory body. These guidelines basically contain the technical specifications of the specific power plant and provide the knowledge of the discharge limit of the radioactive effluent into the environment through atmospheric and aquatic route. However, operational constraints sometimes may violate the technical specification due to which there may be a failure to satisfy the stipulated dose apportioned to that plant. In a site having multi facilities sum total of the dose apportioned to all the facilities should be constrained to 1 mSv/year to the members of the public. Dose apportionment scheme basically stipulates the limit of the gaseous and liquid effluent released into the environment. Existing methodology of dose apportionment is subjective in nature that may result the discharge limit of the effluent in atmospheric and aquatic route in an adhoc manner. Appropriate scientific basis for dose apportionment is always preferable rather than judicial basis from the point of harmonization of establishing the dose apportionment. This paper presents an attempt of establishing the discharge limit of the gaseous and liquid effluent first on the basis of the existing value of the release of the same. Existing release data for a few years (for example 10 years) for any nuclear power station have taken into consideration. Bootstrap, a resampling technique, has been adopted on this data sets to generate the population which subsequently provide the corresponding population distribution of the effluent release. Cumulative distribution of the population distribution obtained is constructed and using this cumulative distribution, 95th percentile (upper bound) of the discharge limit of the radioactive effluents is computed. Dose apportioned for a facility is evaluated using this estimated upper bound of the release limit. Paper describes the detail of the bootstrap method in evaluating the

  2. Paducah Gaseous Diffusion Plant Environmental report for 1990

    Energy Technology Data Exchange (ETDEWEB)

    Counce-Brown, D. (ed.)

    1991-09-01

    This two-part report, Paducah Gaseous Diffusion Plant Site Environmental Report for 1990, is published annually. It reflects the results of a comprehensive, year-round program to monitor the impact of operations at Paducah Gaseous Diffusion Plant (PGDP) on the area's groundwater and surface waters, soil, air quality, vegetation, and wildlife. In addition, an assessment of the effect of PGDP effluents on the resident human population is made. PGDP's overall goal for environmental management is to protect the environment and PGDP's neighbors and to maintain full compliance with all current regulations. The current environmental strategy is to identify any deficiencies and to develop a system to resolve them. The long-range goal of environmental management is to minimize the source of pollutants, to reduce the formation of waste, and to minimize hazardous waste by substitution of materials.

  3. Determination of calibration factors for field measurements of liquid and gaseous activities

    International Nuclear Information System (INIS)

    Jose, M.T.; Ravi, T.; Raghunath, V.M.

    1994-01-01

    While working out the procedures for calibration and activity estimation of 41 Ar gaseous effluent earlier, it was felt necessary to obtain similar factors for liquid and gas activity measurements for other energies also. The paper describes the work done towards this and the conversion factors and minimum detectable levels established. (author). 3 tabs., 1 ref

  4. Beta-ray depth dose in tissue equivalent material due to gaseous radioactive effluents from nuclear power plants

    International Nuclear Information System (INIS)

    Schadt, W.W.

    1978-01-01

    The magnitude of the absorbed dose to skin from beta particles emitted by the radionuclides in gaseous effluents from boiling water nuclear power reactors is investigated in this dissertation. Using the radionuclide release patterns of F. Brutschy and the beta dosimetry methods of M. Berger, an equation is derived which gives the dose rate in rads per day when the total radionuclide concentration is one microcurie per gram of air. The coefficients in the equation are presented for a wide range of reactor gas hold-up times (48 minutes to 6 days) and plume environmental transit time (0.5 to 60 minutes). The beta dose rates at the skin surface are found to range from 3.9 to 26.7 rads per day. An upper limit of the relative standard deviation in the dose rate is estimated to be 30 percent. The techniques used to develop the equation are applied to data from the Millstone Nuclear Power Station obtained during the summer of 1972. The beta dose at a site 1.7 miles from the reactor is determined to have been 675 millirads per year at the skin surface and 476 millirads per year at a depth of 200 micrometers. At a site 5.1 miles from the reactor these dose rates were 138 and 100 millirads per year respectively

  5. Decision no 2009-DC-0158 of the 15. of September 2009 by the Nuclear Safety Authority specifying instructions related to modalities of water sampling and consumption, and of release in the environment of liquid and gaseous effluents from the base nuclear installation n. 29 operated by the CIS Bio International on the district of Saclay (Essonne department)

    International Nuclear Information System (INIS)

    2009-01-01

    After references to the different legal and official documents (codes, orders, minister's opinion, public surveys, administrative authorizations, local community opinion), this document specifies the instructions related to modalities of water sampling and consumption, and of release in the environment of liquid and gaseous effluents from the base nuclear installation operated by CIS Bio International in Saclay. These instructions and provisions concern the general means implemented by the operator, records, the control by authorities, the limits of water sampling and consumption, the water sampling process, the sampling works and their maintenance and control, the release of liquid, gaseous and radioactive effluents, their control and their transfer, the limit values for different compounds and species, the control of environment around the site, the information of authorities and of population

  6. A guide for preparing Hanford Site facility effluent monitoring plans

    International Nuclear Information System (INIS)

    Nickels, J.M.

    1992-06-01

    This document provides guidance on the format and content of effluent monitoring plans for facilities at the Hanford Site. The guidance provided in this document is designed to ensure compliance with US Department of Energy (DOE) Orders 5400.1 (DOE 1988a), 5400.3 (DOE 1989a), 5400.4 (DOE 1989b), 5400.5 (DOE 1990a), 5480.1 (DOE 1982), 5480.11 (DOE 1988b), and 5484.1 (DOE 1981). These require environmental monitoring plans for each site, facility, or process that uses, generates, releases, or manages significant pollutants of radioactive or hazardous materials. In support of DOE Orders 5400.5 (Radiation Protection of the Public and the Environment) and 5400.1 (General Environmental Protection Program), the DOE Environmental Regulatory Guide for Radiological Effluent Monitoring and Environmental Surveillance (DOE 1991) should be used to establish elements of a radiological effluent monitoring program in the Facility Effluent Monitoring Plan. Evaluation of facilities for compliance with the US Environmental Protection Agency Clean Air Act of 1977 requirements also is included in the airborne emissions section of the Facility Effluent Monitoring Plans. Sampling Analysis Plans for Liquid Effluents, as required by the Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement), also are included in the Facility Effluent Monitoring Plans. The Facility Effluent Monitoring Plans shall include complete documentation of gaseous and liquid effluent sampling and monitoring systems

  7. Study on radioactive release of gaseous and liquid effluents during normal operation of AP1000

    International Nuclear Information System (INIS)

    Gong Quan; Zhou Jing; Liu Yu

    2014-01-01

    The gaseous and liquid radioactive releases of pressurized water reactors plant during normal operation are an important content of environmental impact assessment and play a significant role in the design of nuclear power plant. According to the design characters of AP1OOO radioactive waste management system and the study on the calculation method and the release pathways, the calculation model of the gaseous and liquid radioactive releases during normal operation for AP1OOO are established. Base on the established calculation model and the design parameters of AP1000, the expected value of gaseous and liquid radioactive releases of AP1OOO is calculated. The results of calculation are compared with the limits in GB 6249-2011 and explain the adder that is included tu account for anticipated operational occurrences, providing a reference for environmental impact assessment of pressurized water reactor. (authors)

  8. Raffinate treatment at the Portsmouth Gaseous Diffusion Plant

    International Nuclear Information System (INIS)

    Acox, T.A.

    1983-01-01

    Raffinate solutions, which contain uranium, technetium, nitrates, and lesser amounts of heavy metals, are produced in the decontamination and uranium recovery operations at the Portsmouth Gaseous Diffusion Plant. These solutions are presently being placed in temporary storage until three treatment facilities are constructed which will produce an environmentally acceptable effluent from the raffinate. These facilities are: (1) The Heavy Metals Precipitation Facility; (2) The Technetium Ion Exchange Facility; and (3) The Biodenitrification Pilot Plant. When the facilities are completed, the raffinate will be treated in 500 gallon batches. The first treatment is the heavy metals precipitation by caustic addition and filtering. The effluent proceeds to the ion exchange columns where the technetium is removed by adsorption onto a strongly basic, anion exchange resin which has been converted to the hydroxyl form. Following ion exchange, the solution is transported to the biodenitrification pilot plant. The biodenitrification column is a fluidized-bed using bacteria-laden coal particles as the denitrifying media. The resulting effluent should meet the limits established by the US EPA for all metals and nitrate. Technetium will be 98+% removed and the uranium concentration will be less than one milligram per liter. 13 references

  9. Effective equivalent dose in the critical group due to release of radioactive effluents

    International Nuclear Information System (INIS)

    Santos, John W.A. dos; Varandas, Luciana R.; Souza, Denise N.; Souza, Cristiano B.F.; Lima, Sandro Leonardo N.; Mattos, Marcos Fernando M.; Moraes, Jose Adenildo T.

    2005-01-01

    To ensure that the emissions of radioactive material by liquid and gaseous pathways are below applicable limits it is necessary to evaluate the effective equivalent dose in the critical group, which is a magnitude that takes into consideration the modeling used and the terms radioactive activity source. The calculation of this dose considers each radionuclide released by the activity of Nuclear plant, liquid and gaseous by, and the sum of the values obtained is controlled so that this dose does not exceed the goals of the regulatory body, the CNEN and the goals established by the Nuclear power plant. To hit these targets various controls are used such as: controls for effluent monitors instrumentation, environmental monitoring programs, effluent release controls and dose calculation in the environment. According to the findings, it is concluded that during the period of operation of the plants, this dose is below of the required limits

  10. Palisades Nuclear Plant. Radioactive effluents and environmental monitoring sections to second annual operating report

    International Nuclear Information System (INIS)

    1977-01-01

    A total of 0.435 Ci of radioactive liquid effluent less tritium was released with 19.63 Ci of tritium. Both liquid and gaseous releases were within permissible limits. There were 8 Ci of solid wastes stored on the site as of 12/31/76. Data clearly shows there was no detectable increase in radioactivity levels in the environmental media that can be attributed to plant effluents. Monitoring reports are presented concerning fish, meteorology, noise, and cooling tower drift

  11. Radioactive effluents from CANDU 6 reactors during normal operation

    International Nuclear Information System (INIS)

    Boss, C.R.; Allsop, P.J.

    1995-12-01

    During routine operation of a CANDU 6 reactor, various gaseous, liquid, and solid radioactive wastes are generated. The layout of the CANDU 6 reactor and the design of its systems ensure that these are minimized, but small quantities of gaseous and liquid wastes are continually discharged at very low concentrations. This report discusses the make-up of these chronically generated gaseous and liquid effluents. From a safety perspective, the doses to individual members of the public resulting from radioactive wastes chronically discharged from CANDU 6 reactors have been negligible. Similarly, doses to the regional and global populations have been negligible, generally less than 0.001% of background. While far below regulatory limits, releases of tritium, noble gases and gross β - -γ have been the most radiologically significant emissions, while radioiodine and particulates have had the greatest potential to deliver public dose. (author). 8 refs., 16 tabs., 3 figs

  12. Decision no 2010-DC-0182 by the Nuclear Safety Authority on the 18. of May 2010 specifying the limits of releases in the environment of liquid and gaseous effluents of civil base nuclear installations no 46, no 74 and no 100 operated by Electricite de France-Societe Anonyme (EDF-SA) on the district of Saint-Laurent-Nouan (Loir-et-Cher department)

    International Nuclear Information System (INIS)

    2010-01-01

    This document contains references to the different legal and official documents (codes, orders, minister's opinion, public surveys, administrative authorizations, local community opinion) at the root of this specification of limits related to releases in the environment of liquid and gaseous effluents of civil base nuclear installations operated by Electricite de France-Societe Anonyme (EDF-SA) on the district of Saint-Laurent-Nouan. Commented tables in appendix present the limits for different radioactive emissions (carbon 14, hydrogen 3, iodine, radioactive rare earths, and other alpha, beta and gamma emitters) from these different installations, but also the maximum admitted concentrations for gaseous chemical effluents (boric acid, hydrazine, morpholine, phosphates, nitrates, various metals, and so on). The limits for thermal releases are also specified

  13. Experimental study of the tritium distribution in the effluents resulting from the sodium hydrolysis

    Energy Technology Data Exchange (ETDEWEB)

    Chassery, A. [CEA, DEN, Centre de Cadarache, Saint-Paul-lez-Durance (France); Universite de Toulouse, Laboratoire de Genie Chimique, Toulouse (France); CNRS, Laboratoire de Genie Chimique, Toulouse (France); Lorcet, H.; Godlewski, J; Liger, K.; Latge, C. [CEA, DEN, Centre de Cadarache, Saint-Paul-lez-Durance (France); Joulia, X. [Universite de Toulouse, Laboratoire de Genie Chimique, Toulouse (France); CNRS, Laboratoire de Genie Chimique, Toulouse (France)

    2015-03-15

    Within the framework of the dismantling of fast breeder reactors in France several processes are under investigation regarding sodium disposal. One of them, called ELA (radioactive sodium waste treatment process), is based on the implementation of the sodium-water reaction, in a controlled and progressive way, to remove residual sodium. This sodium contains impurities such as sodium hydride, sodium oxide and tritiated sodium hydride. The hydrolysis of these various chemical species leads to the production of a liquid effluent, mainly composed of an aqueous solution of sodium hydroxide, and a gaseous effluent, mainly composed of nitrogen (inert gas), hydrogen and steam. The tritium is distributed between these effluents, and, within the gaseous effluent, according to its forms HT and HTO (tritiated water). HTO being 10,000 times more radio-toxic than HT, a precise knowledge of the mechanisms governing the phase distribution of tritium is necessary. This paper presents the first experimental results from a parametric study on the tritium distribution between the various effluents generated during hydrolysis operations. A series of experiments have been performed in order to study the influence of water flow rate, argon flow rate, initial mass and specific activity of the hydrolyzed sodium sample. An important influence of the total tritium concentration in the hydrolyzed sample has been highlighted. As for the phenomena suspected to be responsible for the phase change of tritiated water, in the studied range of parameters, vaporization induced by the heat of reactions seems to be dominant over the evaporation induced by the inert gas flow rate.

  14. Decision no 2010-DC-0189 by the Nuclear Safety Authority on the 7. of July 2010 specifying to Electricite de France-Societe Anonyme (EDF-SA) instructions related to modalities of water sampling and consumption, and of release in the environment of liquid and gaseous effluents for the operation of the Flamanville 1 (IBN n 108), Flamanville 2 (INB n 109) and Flamanville 3 (INB n 167) reactors

    International Nuclear Information System (INIS)

    2010-01-01

    After references to the different legal and official documents (codes, orders, minister's opinion, public surveys, administrative authorizations, local community opinion), this document specifies the instructions related to modalities of water sampling and consumption, and of release in the environment of liquid and gaseous effluents from three nuclear reactors. These instructions and provisions concern the general means implemented by the operator, records, the control by authorities, the limits of water sampling and consumption, the water sampling process, the sampling works and their maintenance and control, the release of liquid, gaseous and radioactive effluents, their control, the control of the environment (air, soil, surface and underground water, sampling point implantation), the information of authorities and of population

  15. Decision no 2010-DC-0183 by the Nuclear Safety Authority on the 18. of May 2010 specifying instructions related to modalities of water sampling and consumption, and of release in the environment of liquid and gaseous effluents from the base nuclear installations no 46, no 74 and no 100 operated by Electricite de France-Societe Anonyme (EDF-SA) on the district of Saint-Laurent-Nouan (Loir-et-Cher department)

    International Nuclear Information System (INIS)

    2010-01-01

    After references to the different legal and official documents (codes, orders, minister's opinion, public surveys, administrative authorizations, local community opinion), this document specifies the instructions related to modalities of water sampling and consumption, and of release in the environment of liquid and gaseous effluents from some specific base nuclear installations. These instructions and provisions concern the general means implemented by the operator, records, the control by authorities, the limits of water sampling and consumption, the water sampling process, the sampling works and their maintenance and control, the release of liquid, gaseous and radioactive effluents, their control, and the information of authorities and of population

  16. Decision no 2009-DC-0155 of the 15. of September 2009 by the Nuclear Safety Authority specifying the limits of releases in the environment of liquid and gaseous effluents of base nuclear installations n. 18, 35, 40, 49, 50, 72, 77 and 101 operated by the Atomic Energy Commissariat (CEA) in its Saclay Centre, located on the districts of Saclay, Saint-Aubin and Villiers-le-Bacle (Essonne department)

    International Nuclear Information System (INIS)

    2009-01-01

    This document contains references to the different legal and official documents (codes, orders, minister's opinion, public surveys, administrative authorizations, local community opinion) at the root of this specification of limits related to releases in the environment of liquid and gaseous effluents of base nuclear installations of the Saclay Centre operated by the Atomic Energy Commissariat (CEA). Tables present the limits for different radioactive emissions (carbon 14, hydrogen 3, iodine, radioactive rare earths, and other alpha, beta and gamma emitters) from these different installations, but also the maximum admitted concentrations for gaseous chemical effluents (HCl, HF, NOx, CO, and so on), as well as limits for thermal releases

  17. Metodologia

    OpenAIRE

    Saraiva, Maria Elizabeth Fonseca

    2017-01-01

    Para a análise dos dados que apresento abaixo procedeu-se à seguinte metodologia: numa primeira instância, foram distribuídos 40 testes para alunos doCurso de Graduação da FALE/UFMG. Nestes testes havia 11 pares de frases distribuídas assim: em (a), alocaram-se as orações cujos complementos do verbo se apresentavam desacompanhados de preposição e, em (b), aquelas cujos complementos vinham introduzidos por esse elemento.

  18. Metodologia

    OpenAIRE

    Boal-Palheiros, Graça; Veloso, Ana Luísa; Cruz, Ana Isabel; Boia, Pedro Santos

    2017-01-01

    Neste capítulo, serão apresentadas e fundamentadas as metodologias utilizadas no estudo da Orquestra Geração (OG). Adotando-se diferentes perspetivas teóricas, várias questões de investigação foram colocadas e diver- sas abordagens metodológicas foram sendo utilizadas, no sentido de se explorar o caso da OG – um caso complexo e multidimensional. Procurou-se, assim, compreender a realidade multifacetada deste projeto musical, social e pedagógico e aprofundar o conhecimento so...

  19. Order of the 10 january 2003 authorizing the national agency for the radioactive wastes management to follow the gaseous and liquid effluents release for the exploitation of the radioactive wastes storage center of the Manche; Arrete du 10 janvier 2003 autorisant l'Agence nationale pour la gestion des dechets radioactifs a poursuivre les rejets d'effluents gazeux et liquides pour l'exploitation du centre de stockage de dechets radioactifs de la Manche

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-01-01

    This document, took out from the Official Journal, is the law text relative to the order of the 10 january 2003 authorizing the national agency for the radioactive wastes management to follow the gaseous and liquid effluents release for the exploitation of the radioactive wastes storage center of the Manche. (A.L.B.)

  20. Evaluation of the use of activated carbon for the filtration of gaseous effluents generated in the production of the radiopharmaceutical FDG-{sup 18}F; Avaliação do uso de carvão ativado para filtração de efluentes gasosos gerados na produção do radiofármaco FDG-{sup 18}F

    Energy Technology Data Exchange (ETDEWEB)

    Cunha, R.S.; Goulart, A.S.; Flores, M.R.; Saibt, M., E-mail: rafael@nucleorad.com.br [NUCLEORAD Soluções em Proteção Radiológica, Porto Alegre, RS (Brazil)

    2017-07-01

    Gaseous rejects generated in the production of FDG-{sup 18}F are produced mainly during the irradiation of the enriched water (H2O{sup 18}) within the niobium / target body at the cyclotron accelerator and during the process of FDG-{sup 18}F synthesis in the synthesizer modules within the cell hot. In order to reduce the levels of gaseous effluents emitted, activated carbon filters are used in the exhaust system. These have the ability to adsorb the {sup 18}F gaseous molecules generated in the synthesis. This work aims to quantify the efficiency of the activated carbon filters in relation to the dose rate before and after the passage of the gases through the filtration system. To quantify the values in the exhaust system, two radiation detectors were used, in the equivalent dose rate mode in μSv/h. To evaluate the values obtained, graphs of the levels before and after the filtration system were generated. These graphs were compared to each other, relating the values found. The generated graphs showed a high efficiency in the filtration of gaseous effluents. Several dose rate peaks are presented in the exhaust system during FDG-{sup 18}F synthesis, however after the passage of the gases through the filters these peaks become values very close to the Background values.

  1. Quantification of effluents in the production of nuclear fuel

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, Mayara C.C.B.; Riella, Humberto G.; Carvalho, Elita F.U. de, E-mail: mcostac@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-07-01

    At the Instituto de Pesquisa Energéticas e Nucleares (IPEN), the Centro de Combustível Nuclear (CCN), Sao Paulo, SP, Brazil, is responsible for manufacturing fuels for the IEA-R1 reactor and, possibly, the multipurpose reactor fuels. In order to meet the demand for both reactors, the CCN developed a new plant. The production process of the fuel generates several types of effluents - containing uranium or not - being solid, liquid and gaseous with varied physical and chemical characteristics. The objective of this work is to follow the nuclear fuel production process and to identify, quantify and characterize the effluents, especially the liquid ones, to later elaborate a plan of management of these and eventually dispose in a responsible way in the environment. (author)

  2. Quantification of effluents in the production of nuclear fuel

    International Nuclear Information System (INIS)

    Sakai, Mayara C.C.B.; Riella, Humberto G.; Carvalho, Elita F.U. de

    2017-01-01

    At the Instituto de Pesquisa Energéticas e Nucleares (IPEN), the Centro de Combustível Nuclear (CCN), Sao Paulo, SP, Brazil, is responsible for manufacturing fuels for the IEA-R1 reactor and, possibly, the multipurpose reactor fuels. In order to meet the demand for both reactors, the CCN developed a new plant. The production process of the fuel generates several types of effluents - containing uranium or not - being solid, liquid and gaseous with varied physical and chemical characteristics. The objective of this work is to follow the nuclear fuel production process and to identify, quantify and characterize the effluents, especially the liquid ones, to later elaborate a plan of management of these and eventually dispose in a responsible way in the environment. (author)

  3. Order of the 17. of June 2010 approving the decision no 2010-DC-0182 by the Nuclear Safety Authority on the 18. of May 2010 specifying the limits of releases in the environment of liquid and gaseous effluents of civil base nuclear installations no 46, 74 and 100 operated by Electricite de France-Societe Anonyme (EDF-SA) on the district of Saint-Laurent-Nouan (Loir-et-Cher department)

    International Nuclear Information System (INIS)

    2010-01-01

    This legal publication contains references to the different legal and official documents (codes, orders, minister's opinion, public surveys, administrative authorizations, local community opinion) at the root of this specification of limits related to releases in the environment of liquid and gaseous effluents of civil base nuclear installations operated by Electricite de France-Societe Anonyme (EDF-SA) on the district of Saint-Laurent-Nouan. Tables present the limits for different radioactive emissions (carbon 14, hydrogen 3, iodine, radioactive rare earths, and other alpha, beta and gamma emitters) from these different installations, but also the maximum admitted concentrations for gaseous chemical effluents (boric acid, hydrazine, morpholine, phosphates, nitrates, various metals, and so on). The limits for thermal releases are also specified

  4. Techniques to limit gaseous releases in case of reactor accident. Choice criteria - present solutions

    International Nuclear Information System (INIS)

    Billard, Francois; Lavie, Jean-Marie

    1964-10-01

    Within the frame of the study of radiological risks associated with a reactor accident in order to define the required responses, this study comprises, on the one hand, an analysis of the different accident types in order to select typical accidents, and on the other hand, a site-based analysis to define the maximum admissible radioactivity release for a given site. The determination of minimum required coefficient of risk reduction results from a compromise between the choice of reactor configuration type and the efficiency of purification devices, while taking into account minimum characteristics of the enclosure mechanical strength, local release conditions, and nature of gaseous effluents to be processed. After a review of available containment techniques, the author applies this analysis method to the different French reactor types. He gives a brief description of adopted solutions for the most typical French reactors in terms of characteristics of venting and filtration devices. As data quality is a crucial requirement, the author outlines the need for further studies regarding fission product emission and transfer, the purification of gaseous effluents and their diffusion in the atmosphere [fr

  5. Production of gaseous or vaporous fuels from solid carbonaceous materials

    Energy Technology Data Exchange (ETDEWEB)

    1951-05-16

    A process for the production of gaseous or vaporous fuels from solid carbonaceous materials consists of subjecting the materials in separate zones to at least three successive thermal treatments at least two of which are carried out at different temperature levels. The materials being maintained in zones in the form of beds of finely divided particles fluidized by the passage of gases or vapors upwardly there-through, and recovering product vapors or gases overhead. The total hot gaseous or vaporous effluent and entrained solids from one of the zones is passed directly without separation to another of the zones situated closely adjacent to and vertically above the first named zone in the same vessel, and the heat required in at least one of the thermal treatment zones is supplied at least in part as the sensible heat of residual solids transferred from a thermal treatment zone operated at a higher temperature.

  6. Environmental and effluent monitoring at Lucas Heights Research Laboratories, 1994

    International Nuclear Information System (INIS)

    Hoffmann, E.L.; Camilleri, A.; Loosz, T.; Farrar, Y.

    1995-12-01

    Results are presented of environmental and effluent monitoring conducted in the vicinity of the Lucas Heights Research Laboratories (LHRL) during 1994. All low level liquid and gaseous effluent discharges complied with existing discharge authorisations and relevant environmental regulations. Potential effective doses to the general public from controlled airborne discharges during this period, were estimated to be less than 0.015 mSv/year for receptor locations on the 1.6 km buffer zone boundary around HIFAR. This value represents 1.5 % of the 1 mSv/year dose limit for long term exposure that is recommended by the National Health and Medical Research Council, and 5 % of the site dose constraint of 0.3 mSv/year adopted by ANSTO. 27 refs., 22 tabs., 6 figs

  7. Environmental and effluent monitoring at Lucas Heights Research Laboratories, 1994

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, E L; Camilleri, A; Loosz, T; Farrar, Y

    1995-12-01

    Results are presented of environmental and effluent monitoring conducted in the vicinity of the Lucas Heights Research Laboratories (LHRL) during 1994. All low level liquid and gaseous effluent discharges complied with existing discharge authorisations and relevant environmental regulations. Potential effective doses to the general public from controlled airborne discharges during this period, were estimated to be less than 0.015 mSv/year for receptor locations on the 1.6 km buffer zone boundary around HIFAR. This value represents 1.5 % of the 1 mSv/year dose limit for long term exposure that is recommended by the National Health and Medical Research Council, and 5 % of the site dose constraint of 0.3 mSv/year adopted by ANSTO. 27 refs., 22 tabs., 6 figs.

  8. Methodology of adjustment point in the post treatment of gaseous effluents

    International Nuclear Information System (INIS)

    Vizuet G, J.; Molina, G.

    2005-01-01

    The methodology to determine the adjustment points of the monitoring system of gaseous discharges is based on the stipulations of the 10CFR20, which are expressed in terms of limit concentrations for the outstanding radionuclides, and of dose limits for the individuals members of the public. Besides the points of liberation properly said, like they are the chimneys of the reactor buildings and of turbine, the points of adjustment of the monitoring instrumentation that watches in real time the discharge of the Treatment system of output gases, to the HVAC of the waste building; they also undergo to the same methodology, with the approaches previously described. (Author)

  9. Report on the Biological Monitoring Program at Paducah Gaseous Diffusion Plant December 1992--December 1993

    Energy Technology Data Exchange (ETDEWEB)

    Kszos, L.A.; Hinzman, R.L.; Peterson, M.J.; Ryon, M.G.; Smith, J.G.; Southworth, G.R.

    1995-06-01

    On September 24, 1987, the Commonwealth of Kentucky Natural Resources and Environmental Protection Cabinet issued an Agreed Order that required the development of a Biological Monitoring Program (BMP) for the Paducah Gaseous Diffusion Plant (PGDP). The goals of BMP are to demonstrate that the effluent limitations established for PGDP protect and maintain the use of Little Bayou and Big Bayou creeks for growth and propagation of fish and other aquatic life, characterize potential health and environmental impacts, document the effects of pollution abatement facilities on stream biota, and recommend any program improvements that would increase effluent treatability. The BMP for PGDP consists of three major tasks: effluent and ambient toxicity monitoring, bioaccumulation studies, and ecological surveys of stream communities (i.e., benthic macroinvertebrates and fish). This report includes ESD activities occurring from December 1992 to December 1993, although activities conducted outside this time period are included as appropriate.

  10. Facility effluent monitoring plan for the uranium trioxide facility

    International Nuclear Information System (INIS)

    Thompson, R.J.; Sontag, S.

    1991-11-01

    A facility effluent monitoring plant is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan is the first annual report. It shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated as a minimum every three years. The UO 3 Plant is located in the south-central portion of the 200 West Area of the Hanford Site. The plant consists of two primary processing buildings and several ancillary facilities. The purpose of the UO 3 Plant is to receive uranyl nitrate hexahydrate (UNH) from the Plutonium-Uranium Extraction (PUREX) Plant, concentrate it, convert the UNH to uranium trioxide (UO 3 ) powder by calcination and package it for offsite shipment. The UO 3 Plant has been placed in a standby mode. There are two liquid discharges, and three gaseous exhaust stacks, and seven building exhausters that are active during standby conditions

  11. Method and device for processing aqueous effluents containing tritiated water, electrode used in that device and its fabrication process

    International Nuclear Information System (INIS)

    Bellanger, G.; Giroux, P.

    1983-01-01

    In this process an electrolyte, such as sodium hydroxide, is added to the effluent and the solution is electrolysed to obtain gaseous tritium. The electrolytic cell includes a cathode made with a metal facilitating tritium diffusion, e.g. Pd-Ag alloy. The cathode constitutes a separation wall between the electrolysed solution and a compartment where tritium is recovered after diffusion through the cathode. Application is made for tritium recovery in effluents coming from spent fuel reprocessing [fr

  12. Graphic displays on PCs of gaseous diffusion models of radionuclide releases to the atmosphere

    International Nuclear Information System (INIS)

    Campo Ortega, E. del

    1993-01-01

    The well-known MESOI program has been modified and improved to adapt it to a PC/AT with VGA colour monitor. Far from losing any of its powerful characteristics to calculate the transport, diffusion, deposition and decay of gaseous radioactive effluents discharged to the atmosphere, it has been enhanced to allow graphic viewing of concentrations, wind speed and direction and puff locations in colour, all on a background map of the site. The background covers a 75 x 75 km square and has a graphic grid density of 421 x 421 pixels. This means that effluent concentration is represented approximately every 170 metres in the 'clouded-area'. Among the modifications and enhancements made, the following are of particular interest: 1. A new subroutine called NUBE has been added, which calculates the distribution of effluent concentration of activity in a grid of 421 x 421 pixels. 2. Several subroutines have been added to obtain graphic displays and printouts of the cloud, wind field and puff locations. 3. Graphic display of the geographic plane of the area surrounding the effluent release point. 4. Off-line preparation of meteorological and topographical data files necessary for program execution. (author)

  13. Report on the biological monitoring program at Paducah Gaseous Diffusion Plant, January--December 1997

    Energy Technology Data Exchange (ETDEWEB)

    Kszos, L.A.; Peterson, M.J.; Ryon, M.G.; Smith, J.G.; Southworth, G.R.

    1998-03-01

    On September 24, 1987, the Commonwealth of Kentucky Natural Resources and Environmental Protection Cabinet issued an Agreed Order that required the development of a Biological Monitoring Program (BMP) for the Paducah Gaseous Diffusion Plant (PGDP). A plan for the biological monitoring of the receiving streams was implemented in 1987 and consisted of ecological surveys, toxicity monitoring of effluents and receiving streams, evaluation of bioaccumulation of trace contaminants in biota, and supplemental chemical characterization of effluents. Beginning in fall 1991, the Environmental Sciences Division (ESD) at Oak Ridge National Laboratory added data collection and report preparation to its responsibilities for the PGDP BMP. The BMP has been continued because it has proven to be extremely valuable in (1) identifying those effluents with the potential for adversely affecting instream fauna, (2) assessing the ecological health of receiving streams, and (3) guiding plans for remediation and protecting human health. The BMP for PGDP consists of three major tasks: (1) effluent toxicity monitoring, (2) bioaccumulation studies, and (3) ecological surveys of benthic macroinvertebrate communities and fish. With the exception of the benthic macroinvertebrate community surveys, this report focuses on activities from January to December 1997.

  14. Report on the biological monitoring program at Paducah Gaseous Diffusion Plant, January-December 1997

    International Nuclear Information System (INIS)

    Kszos, L.A.; Peterson, M.J.; Ryon, M.G.; Smith, J.G.; Southworth, G.R.

    1998-03-01

    On September 24, 1987, the Commonwealth of Kentucky Natural Resources and Environmental Protection Cabinet issued an Agreed Order that required the development of a Biological Monitoring Program (BMP) for the Paducah Gaseous Diffusion Plant (PGDP). A plan for the biological monitoring of the receiving streams was implemented in 1987 and consisted of ecological surveys, toxicity monitoring of effluents and receiving streams, evaluation of bioaccumulation of trace contaminants in biota, and supplemental chemical characterization of effluents. Beginning in fall 1991, the Environmental Sciences Division (ESD) at Oak Ridge National Laboratory added data collection and report preparation to its responsibilities for the PGDP BMP. The BMP has been continued because it has proven to be extremely valuable in (1) identifying those effluents with the potential for adversely affecting instream fauna, (2) assessing the ecological health of receiving streams, and (3) guiding plans for remediation and protecting human health. The BMP for PGDP consists of three major tasks: (1) effluent toxicity monitoring, (2) bioaccumulation studies, and (3) ecological surveys of benthic macroinvertebrate communities and fish. With the exception of the benthic macroinvertebrate community surveys, this report focuses on activities from January to December 1997

  15. Control of effluents and environmental surveillance of the CEA centres. 1997 status

    International Nuclear Information System (INIS)

    1998-06-01

    The environmental quality in the vicinity of CEA facilities is a major concern of the safety policy of the CEA. The aim of this document is to inform the public about the gaseous and liquids radioactive effluents released by the CEA centres under the permission of the ministry. It provides a status of the effluents and of the radioactivity levels measured near the CEA centres in 1997, using air, water, vegetation and milk samples. A comparison is made with the measurements performed during the 1993-1996 period. The data presented comes from the regulatory registers transmitted to the agency for the protection against ionizing radiations (OPRI) which belongs to the ministry of health. (J.S.)

  16. Paducah Gaseous Diffusion Plant Annual Site Environmental Report summary for 1993

    International Nuclear Information System (INIS)

    1994-11-01

    This report contains summaries of the environmental programs at Paducah Gaseous Diffusion Plant, environmental monitoring and the results, and the impact of operations on the environment and the public for 1993. The environmental monitoring program at Paducah includes effluent monitoring and environmental surveillance. Effluent monitoring is measurement of releases as they occur. Contaminants are released through either airborne emissions or liquids discharged from the plant. These releases occur as part of normal site operations, such as cooling water discharged from the uranium enrichment cascade operations or airborne releases from ventilation systems. In the event of system failure, this monitoring provides timely warning so that corrective action can be taken before releases reach an unsafe level. Environmental surveillance tracks the dispersion of materials into the environment after they have been released. This involves the collection of samples from various media, such as water, soil, vegetation, and food crops, and the analysis of these samples for certain radionuclides, chemicals, and metals

  17. Portsmouth Gaseous Diffusion Plant Annual Site Environmental Report summary for 1993

    International Nuclear Information System (INIS)

    1994-11-01

    This report contains summaries of the environmental programs at Paducah Gaseous Diffusion Plant, environmental monitoring and the results, and the impact of operations on the environment and the public for 1993. The environmental monitoring program at Paducah includes effluent monitoring and environmental surveillance. Effluent monitoring is measurement of releases as they occur. Contaminants are released through either airborne emissions or liquids discharged from the plant. These releases occur as part of normal site operations, such as cooling water discharged from the uranium enrichment cascade operations or airborne releases from ventilation systems. In the event of system failure, this monitoring provides timely warning so that corrective action can be taken before releases reach an unsafe level. Environmental surveillance tracks the dispersion of materials into the environment after they have been released. This involves the collection of samples from various media, such as water, soil, vegetation, and food crops, and the analysis of these samples for certain radionuclides, chemicals, and metals

  18. Espiral construtivista: uma metodologia ativa de ensino-aprendizagem

    Directory of Open Access Journals (Sweden)

    Valéria Vernaschi Lima

    Full Text Available A partir da teoria sociointeracionista da educação e da trajetória das práticas pedagógicas nas sociedades ocidentais, o artigo apresenta a espiral construtivista como uma metodologia ativa de ensino-aprendizagem. Discute as origens e a utilização de metodologias ativas no ensino superior, focalizando: a aprendizagem baseada em problemas, a metodologia da problematização, o método científico e o uso de narrativas, simulações ou atuações em cenários reais de prática. A exploração da espiral construtivista, de acordo com os movimentos: “identificando problemas”; “formulando explicações”; “elaborando questões”; “construindo novos significados”; “avaliando processo e produtos”, destaca semelhanças e diferenças em relação às metodologias ativas focalizadas. Para além dos aspectos metodológicos envolvidos, a intencionalidade educacional na utilização da espiral construtivista é explicitada pela natureza dos disparadores de aprendizagem utilizados e pelo sentido transformador da realidade derivado da postura crítica e reflexiva na interação do “sujeito” e “objeto”.

  19. Control of Effluent Gases from Solid Waste Processing Using Carbon Nanotubes

    Science.gov (United States)

    Fisher, John; Cinke, Martin; Wignarajab, Kanapathipillai

    2005-01-01

    One of the major problems associated with solid waste processing technologies is the release of effluent gases and contaminants that are in gaseous formed from the processes. A number of other gases, in particular NO(x), SO2, NH3, Hydrocarbons (e.g. CH4) do present hazards to the crew in space habitats. Reduction of mass, power, volume and resupply can be achieved by using catalyst impregnated carbon nanotubes as compared to other catalytic systems. The development and characterization of an innovative approach for the control and elimination of gaseous toxins using single walled carbon nanotubes (SWNTs) promise superior performance over conventional approaches. This is due to the ability to direct the selective uptake of gaseous species based on their controllable pore size, high adsorptive capacity and the effectiveness of carbon nanotubes as catalyst supports for gaseous conversion. For example, SWNTs have high adsorptive capacity for NO and the adsorbed NO can be decomposed to N2 and O2 . Experimental results showing the decomposition of NO on metal impregnated carbon nanotubes is presented. Equivalent System Mass (ESM) comparisons are made of the existing TCCS systems with the carbon nanotube technology for removing NO(x). The potential for methane decomposition using carbon nanotubes catalysts is also discussed.

  20. Separation of tritium from reprocessing effluents

    International Nuclear Information System (INIS)

    Bruggeman, A.; Doyen, W.; Harnie, R.; Leysen, R.; Meynendonckx, L.; Monsecour, M.; Goossens, W.R.A.; Baetsle, L.H.

    1980-01-01

    For several years tritium retention has been studied at the Belgian Nuclear Research Centre, SCK/CEN; initially attention was focused on the removal of tritium from gaseous reprocessing effluents. If tritium can be released from the spent fuel into the gaseous phase before any aqueous operation, adsorption on molecular sieves after some isotopic dilution with hydrogen and after complete conversion to (tritiated) water is the most practical collection method. A once-through 15 m 3 .h -1 oxidation-adsorption unit with a closed regeneration system and with a decontamination factor of 1000 at total (tritiated) hydrogen and water inlet concentrations down to 1000 vpm (parts per million by volume) has been constructed and tested at SCK/CEN and it is described in the text. If no special head-end treatment is used an appropriate liquid management inside the reprocessing plant restricts the volume of tritiated aqueous effluents to about 3 m 3 per tonne of LWR fuel processed. However, for further reduction an isotope separation process becomes necessary. SCK/CEN is developing the ELEX process, which is a combination of water ELectrolysis and tritium EXchange between hydrogen and water, the exchange being promoted by a hydrophobic catalyst. For electrolysis under normal conditions an elementary tritium separation factor of 11.6 with a standard deviation of 6% was obtained. As concerns the exchange step a hydrophobic catalyst has been developed which yields for the flow rates used at atmospheric pressure and at 20 0 C an overall exchange rate constant of 9 mol.s -1 .m -3 in a countercurrent trickle-bed reactor. At present an integrated bench scale de-tritiation unit is being built for further tests and for a dynamic demonstration of the ELEX process

  1. Decision no 2009-DC-0156 of the 15. of September 2009 by the Nuclear Safety Authority specifying instructions related to modalities of water sampling and consumption, and of release in the environment of liquid and gaseous effluents from the base nuclear installations n. 18, 35, 40, 49, 50, 72, 77 and 101 operated by the Atomic Energy Commissariat (CEA) in its Saclay Centre, located on the districts of Saclay, Saint-Aubin and Villiers-le-Bacle (Essonne department)

    International Nuclear Information System (INIS)

    2009-01-01

    After references to the different legal and official documents (codes, orders, minister's opinion, public surveys, administrative authorizations, local community opinion), this document specifies the instructions related to modalities of water sampling and consumption, and of release in the environment of liquid and gaseous effluents from some specific base nuclear installations. These instructions and provisions concern the general means implemented by the operator, records, the control by authorities, the limits of water sampling and consumption, the water sampling process, the sampling works and their maintenance and control, the release of liquid, gaseous and radioactive effluents, their control and their transfer, the limit values for different compounds and species, the control of environment around the site, the information of authorities and of population

  2. A metodologia de pesquisa: metassíntese qualitativa

    Directory of Open Access Journals (Sweden)

    Edvonete Souza de Alencar

    2018-01-01

    Full Text Available A metassíntese qualitativa é uma das modalidades de pesquisa bibliográfica que realizam revisões sistemáticas, sendo importante para a busca e definição de alguns aspectos da área de investigação. Identifica as possíveis melhorias que podem ser realizadas nas teorias, nas metodologias e nas tendências de investigação, observando ainda quais aspectos necessitam ser abordados e aprofundados. O artigo apresenta a definição do que é metassíntese qualitativa mencionada por autores como Vosgerau e Romanowski, Romanowski e Ens, Fiorentini, Maranhão e Manrique e Matheus. Aborda os seus benefícios evidenciando os aspectos positivos para sua realização. Assim apresenta como esta metodologia de pesquisa pode ser realizada, mostrando algumas etapas citadas pela autora Matheus. Propõe ainda reflexões trazendo como algumas investigações realizaram suas investigações usando essa metodologia de pesquisa.

  3. A METODOLOGIA ATIVA COMO PROPOSTA PARA O ENSINO DE CIÊNCIAS

    Directory of Open Access Journals (Sweden)

    Eduardo Segura

    2015-12-01

    Full Text Available Este artigo resgata a discussão a respeito da utilização das metodologias ativas no Ensino de Ciências. O seu objetivo consiste em apresentar de forma clara e sucinta a características e a estrutura de três estratégias de ensino baseadas nas metodologias ativas. O embasamento do artigo está em Galiazzi (2000, Pozo e Crespo (2009, Oliveira (2013, Delizoicov, Angotti e Pernambuo (2009, El chaer (2013, Conrado (2013, dentre outros. O percurso metodológico está ancorado na pesquisa bibliográfica e na revisão de literatura dos principais teóricos que discutem a Educação em Ciências e as metodologias ativas. Os resultados apontam para a possibilidade de aplicação das metodologias ativas no Ensino de Ciências.

  4. Experimental study and phenomenological modeling of the hydrolysis of tritiated sodium: influence of experimental conditions on the tritium distribution in the effluents

    International Nuclear Information System (INIS)

    Chassery, Aurelien

    2014-01-01

    Within the framework of the decommissioning of fast reactors, several processes are under investigation regarding sodium disposal. One of them rests on the implementation of the sodium-water reaction (SWR), in a controlled and progressive way, to remove residual sodium containing impurities such as sodium hydrides, sodium oxides and tritiated sodium hydrides. Such a hydrolysis releases some amount of energy and produces a liquid effluent, composed of a solution of soda, and a gaseous effluent, composed of hydrogen, steam and an inert gas. The tritium, originally into the sodium as a soluble (T - ) or precipitate form (NaT), will be distributed between the liquid and gaseous effluent, and according to two chemical forms, the tritium hydride HT and the tritiated water HTO. HTO being 10,000 times more radio-toxic than HT, a precise knowledge of the mechanisms governing the distribution of tritium is necessary in order to estimate the exhaust gas releases and design the process needed to treat the off-gas before its release into the environment. An experimental study has been carried out in order to determine precisely the phenomena involved in the hydrolysis. The influence of the experimental conditions on the tritium distribution has been tested. The results of this study leaded to a phenomenological description of the tritiated sodium hydrolysis that will help to predict the composition of the effluents, regarding tritium. (author) [fr

  5. Order of the 4 March 2014 on the homologation of the decision nr 2014-DC-4016 of the Nuclear Safety Authority of the 16 January 2014 defining the limits of releases in the environment of liquid and gaseous effluents by the basic nuclear installations nr 124, 125, 126 and 137 exploited by EDF-SA in Cattenom (Moselle district)

    International Nuclear Information System (INIS)

    Durand, J.M.

    2014-01-01

    This order issued by the French Ministry of ecology, sustainable development and energy is based on a decision taken by the ASN. It concerns the management of pollutions and of the impact of a nuclear installation on the environment: applicable limits of gaseous (notably carbon 14, tritium, rare gases, iodines), chemical, and liquid effluent release. Tables indicate the maximum concentrations

  6. Aplicação da metodologia Lean Six Sigma para melhoria de um processo produtivo

    OpenAIRE

    Augusto Schaffer

    2016-01-01

    O Lean Six Sigma é a metodologia originada a partir da integração das metodologias Lean e Six Sigma. O Lean Six Sigma procura eliminar as perdas e reduzir os defeitos, agregando os benefícios de cada uma das duas metodologias que a dão origem. O objetivo deste trabalho é aplicar a metodologia Lean Six Sigma para melhoria de um processo produtivo. Neste trabalho é apresentada uma revisão bibliográfica sobre as metodologias Lean e Six Sigma, buscando a compreensão das origens do Lean Six Sigma,...

  7. DOSEFU: Computer application for dose calculation and effluent management in normal operation

    International Nuclear Information System (INIS)

    Martin Garcia, J. E.; Gonzalvo Manovel, A.; Revuelta Garcia, L.

    2002-01-01

    DOSEFU is a computer application on Windows that develops the methodology of nuclear power plant Exterior Dose Calculation Manuals (Manuals de Calculo de Dosis al Exterior-MACADE) for calculating doses in normal operation caused by radioactive liquid and gaseous effluents, for the purpose of enforcing the new Spanish Regulation on Health Protection against Ionizing Radiations, Royal Decree 783/2001 resulting from transposition of Directive 96/29/Euratom whereby the basic rules regarding health protection of workers and the population against risks resulting from ionizing radiations are established. In addition to making dose calculations, DOSEFU generates, on a magnetic support, the information regarding radioactive liquid and gaseous effluents that plants must periodically send to the CSN (ELGA format). The computer application has been developed for the specific case of Jose Cabrera NPP, which is called DOEZOR. This application can be easily implemented in any other nuclear or radioactive facility. The application is user-friendly, as the end user inputs data and executes the different modules through keys and dialogue boxes that are enabled by clicking on the mouse (see figures 2, 3, 4 and 5 ), The application runs under Windows 95. Digital Visual Fortran has been used as the development program, as this does not require additional libraries (DLLs), it can be installed in any computer without affecting other programs that are already installed. (Author)

  8. Metodologias de representação da informação imagética

    Directory of Open Access Journals (Sweden)

    Giovana Deliberali Maimone

    Full Text Available O presente trabalho tem a finalidade de evidenciar algumas das metodologias de representação da informação imagética, revisitando a literatura da área e propondo um modelo de metodologia adaptada a museus brasileiros. Elabora-se uma proposta de metodologia de representação da informação imagética com base nas características de tratamento informacional, a fim de realizar adaptação museológica. Apresentam-se, por fim, as planilhas que evidenciam essa metodologia.

  9. A system for destroying mixed and hazardous wastes with no gas or liquid effluents

    International Nuclear Information System (INIS)

    Camp, D.W.; Upadhye, R.S.

    1992-04-01

    We developed a conceptual design for a processing system in which the organic components of hazardous or mixed waste would be destroyed, while discharging virtually no gaseous or liquid effluents. Only solid products would be produced. For mixed waste feeds these could then be transported and disposed as low level waste. This system would oxidize the organics using any one of several destruction processes adapted to replace air with a mixture of O 2 and recycled CO 2 . Net production Of CO 2 , HC1, and H 2 O in the dosed recycle system would be scrubbed or reacted to solid products such as CaCO 3 , NaCl, and concrete. This no-effluent design may improve community acceptance of a waste destruction system

  10. Application of wet effluent diffusion denuder for measurement of uptake coefficient of gaseous pollutants

    Czech Academy of Sciences Publication Activity Database

    Motyka, K.; Mikuška, Pavel; Večeřa, Zbyněk

    2011-01-01

    Roč. 84, č. 2 (2011), s. 519-523 ISSN 0039-9140 R&D Projects: GA MŽP SP/1A3/148/08; GA MŽP SP/1A3/55/08; GA MŽP SP/1B7/189/07 Institutional research plan: CEZ:AV0Z40310501 Keywords : collection efficiency * wet effluent diffusion denuder * uptake coefficient Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.794, year: 2011

  11. Environmental and effluent monitoring at Lucas Heights Science and Technology Centre, 1996

    International Nuclear Information System (INIS)

    Hoffmann, E.L.; Loosz, T.; Farrar, Y.

    1997-06-01

    Results are presented of environmental and effluent monitoring conducted in the vicinity of the Lucas Heights Science and Technology Centre during 1996. All low-level liquid and gaseous effluent discharges complied with existing discharge authorizations and relevant environmental regulations. Potential effective doses to the general public from controlled airborne discharges during this period, were estimated to be less than 0.010 mSv/year for receptor locations on the 1.6 km buffer zone boundary around HIFAR. This value represents 1% of the 1 mSv/year dose limit for long term exposure that is recommended by thr National Health and Medical Research Council and 3.3% of the site dose constraint of 0.3mSv/year adopted by ANSTO. Details of the environmental sample collection and analytical procedures are given in the appendices. (authors)

  12. Environmental and effluent monitoring at Lucas Heights Science and Technology Centre, 1997

    International Nuclear Information System (INIS)

    Hoffmann, E.L.; Loosz, T.; Farrar, Y

    1998-11-01

    Results are presented of environmental and effluent monitoring conducted in the vicinity of the Lucas Heights Science and Technology Centre (LHSTC) during 1997. All low-level liquid and gaseous effluent discharges complied with existing discharge authorizations and relevant environmental regulations. Potential effective doses to the general public from controlled airborne discharges from HIFAR were estimated utilising the PC-Cream atmospheric dispersion and dosimetry code. The potential effective dose to the public was estimated to be less than 0.010 mSv/year for all receptor locations on the 1.6 km buffer zone boundary around the HIFAR research reactor. This value represents 1% of the 1 mSv/year dose limit for long term exposure that is recommended by the National Health and Medical Research Council and 10% of the HIFAR dose constraint of 0.1 mSv/year

  13. Environmental and effluent monitoring at Lucas Heights Science and Technology Centre, 1996

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, E.L.; Loosz, T.; Farrar, Y.

    1997-06-01

    Results are presented of environmental and effluent monitoring conducted in the vicinity of the Lucas Heights Science and Technology Centre during 1996. All low-level liquid and gaseous effluent discharges complied with existing discharge authorizations and relevant environmental regulations. Potential effective doses to the general public from controlled airborne discharges during this period, were estimated to be less than 0.010 mSv/year for receptor locations on the 1.6 km buffer zone boundary around HIFAR. This value represents 1% of the 1 mSv/year dose limit for long term exposure that is recommended by thr National Health and Medical Research Council and 3.3% of the site dose constraint of 0.3mSv/year adopted by ANSTO. Details of the environmental sample collection and analytical procedures are given in the appendices. (authors). 29 refs., 26 tabs., 6 figs.

  14. Gaseous nebulae

    International Nuclear Information System (INIS)

    Williams, R.E.

    1976-01-01

    Gaseous nebulae are large, tenuous clouds of ionized gas that are associated with hot stars and that emit visible light because of the energy that they receive from the ultraviolet radiation of the stars. Examples include H II regions, planetary nebulae, and nova/supernova remnants. The emphasis is on the physical processes that occur in gaseous nebulae as opposed to a study of the objects themselves. The introduction discusses thermodynamic vs. steady-state equilibrium and excitation conditions in a dilute radiation field. Subsequent sections take up important atomic processes in gaseous nebulae (particle--particle collision rates, radiative interaction rates, cross sections), the ionization equilibrium (sizes of H II regions, ionization of the heavier elements), kinetic temperature and energy balance (heating of the electrons, cooling of the electrons), and the spectra of gaseous nebulae (line fluxes in nebulae). 7 figures, 5 tables

  15. Pedagogia de Projetos como metodologia no trabalho com a educação infantil

    Directory of Open Access Journals (Sweden)

    Patricia Frageri

    2016-12-01

    Full Text Available Este artigo teve como tema a Pedagogia de Projetos como metodologia no trabalho com a Educação Infantil e a pesquisa foi realizada na escola Gente Feliz de Sinop. A investigação teve como objetivo conhecer em que consiste a metodologia de trabalho pautada na pedagogia de projetos, e suas interfaces, no contexto da educação infantil. Os instrumentos de pesquisa foram entrevista e questionário com duas professoras. Os resultados mostram que a instituição prioriza a metodologia de trabalho por projetos e que as professoras estão familiarizadas com essa metodologia buscando construir junto com as crianças as práticas pedagógicas diárias. Palavra-chave: educação infantil; Pedagogia de Projetos; metodologia de trabalho.

  16. Continuously tritium monitoring of the pipe of liquid effluents at the Cea Cadarache; Controle en continu du tritium de la conduite des effluents liquides du CEA Cadarache

    Energy Technology Data Exchange (ETDEWEB)

    Pira, Y

    2004-07-01

    This report is oriented toward the radiation protection of environment that is an essential component of radiation protection. It is necessary to detect any solid, liquid or gaseous abnormal release and to find its origin. The present study bears on a detection instrument in continuously to find tritium in liquid effluents of the Cea Cadarache. After having study the functioning principle of this device, an evaluation of its performances has been realised ( back noise, yield, detection limit) and to a checking in real conditions of utilization. (N.C.)

  17. Paducah Gaseous Diffusion Plant environmental report for 1989

    Energy Technology Data Exchange (ETDEWEB)

    Turner, J.W. (ed.) (Martin Marietta Energy Systems, Inc., Oak Ridge, TN (USA))

    1990-10-01

    This two-part environmental report is published annually. It reflects the results of a comprehensive, year-round program to monitor the impact of operations at Paducah Gaseous Diffusion Plant (PGDP) on the area's groundwater and surface waters, soil, air quality, vegetation, and wildlife. In addition, an assessment of the effect of PGDP effluents on the resident human population is made. PGDP's overall goal for environmental management is to protect the environment and PGDP's neighbors and to maintain full compliance with all current regulations. The current environmental strategy is to identify any deficiencies and to develop a system to resolve them. The long-range goal of environmental management is to minimize the source of pollutants, to reduce the formation of waste, and to minimize hazardous waste by substitution of materials. 36 refs.

  18. METODOLOGIAS ATIVAS DE ENSINO/APRENDIZAGEM: DIFICULDADES DE DOCENTES DE UM CURSO DE ENFERMAGEM

    Directory of Open Access Journals (Sweden)

    Simone Karine da Costa Mesquita

    2016-01-01

    Full Text Available Resumo O estudo objetivou identificar as dificuldades vivenciadas pelos docentes na implementação de metodologias ativas no curso de graduação em enfermagem de uma instituição federal localizada no Rio Grande do Norte. Tratou-se de pesquisa exploratório-descritiva com enfoque qualitativo. As entrevistas semiestruturadas foram aplicadas a vinte sujeitos nos meses de agosto e setembro de 2011 e, posteriormente, analisadas seguindo pressupostos da análise de conteúdo. As principais adversidades elencadas pelos sujeitos da pesquisa foram agrupadas em três categorias de análise: problemas curriculares como empecilho para a aplicação de metodologias ativas de ensino/aprendizagem; resistência do docente em implementar metodologias ativas de ensino/aprendizagem; e dificuldade de compreensão da aplicabilidade das metodologias ativas de ensino/aprendizagem na prática docente. Diante de tais dificuldades, fez-se necessário introduzir novas formas de organizar e produzir o conhecimento, uma vez que a utilização de metodologias ativas poderia favorecer a formação de sujeitos com visão ampliada de saúde, ativos e comprometidos com a transformação da realidade. Compreender a utilização de metodologias ativas é fundamental para atender aos pressupostos do paradigma educacional contemporâneo.

  19. Airborne effluent control at fuel enrichment, conversion, and fabrication plants

    International Nuclear Information System (INIS)

    Mitchell, M.E.

    1976-01-01

    Uranium conversion, enrichment, and fuel fabrication facilities generate gaseous wastes that must be treated prior to being discharged to the atmosphere. Since all three process and/or handle similar compounds, they also encounter similar gaseous waste disposal problems, the majority of which are treated in a similar manner. Ventilation exhausts from personnel areas and equipment off-gases that do not contain corrosive gases (such as HF) are usually passed through roughening and/or HEPA filters prior to release. Ventilation exhausts that contain larger quantities of particles, such as the conversion facilities' U 3 O 8 sampling operation, are passed through bag filters or cyclone separators, while process off-gases containing corrosive materials are normally treated by sintered metal filters or scrubbers. The effectiveness of particle removal varies from about 90 percent for a scrubber alone to more than 99.9 percent for HEPA filters or a combination of the various filters and scrubbers. The removal of nitrogen compounds (N 2 , HNO 3 , NO/sub x/, and NH 3 ) is accomplished by scrubbers in the enrichment and fuel fabrication facilities. The conversion facility utilizes a nitric acid recovery facility for both pollution control and economic recovery of raw materials. Hydrogen removal from gaseous waste streams is generally achieved with burners. Three different systems are currently utilized by the conversion, enrichment, and fuel fabrication plants to remove gaseous fluorides from airborne effluents. The HF-rich streams, such as those emanating from the hydrofluorination and fluorine production operations of the conversion plant, are passed through condensers to recover aqueous hydrofluoric acid

  20. The regulation of radioactive effluent release in France (mainly from large nuclear installations)

    International Nuclear Information System (INIS)

    Hebert, Jean.

    1978-01-01

    In parallel with the licensing system for construction and operation of classified or so-called large nuclear installations (INB) there are in France regulations for the release of radioactive effuents from such installations. The regulations applicable to installations other than INBs are not specifically of a nuclear nature, while those covering INBs, which are analysed in this study, in particular, cover effluent release in liquid or gaseous form. The licensing and control procedures for such release are analysed in detail. (NEA) [fr

  1. Lessons learned from a review of post-accident sampling systems, high range effluent monitors and high concentration particulate iodine samplers

    International Nuclear Information System (INIS)

    Hull, A.P.; Knox, W.H.; White, J.R.

    1987-01-01

    Post-accident sampling systems (PASS), high range gaseous effluent monitors and sampling systems for particulates and iodine in high concentrations have been reviewed at twenty-one licensee sites in Region I of the US Nuclear Regulatory Commission which includes fifteen BWR's and fourteen PWR's. Although most of the installed PASS met the criteria, the highest operational readiness was found in on-line systems that were also used for routine sampling and analysis. The detectors used in the gaseous effluent monitors included external ion chambers, GM tubes, organic scintillators and Cd-Te solid state crystals. Although all were found acceptable, each had its own inherent limitations in the conversion of detector output to the time varying concentration of a post-accident mixture of noble gases. None of the installed particulate and iodine samplers fully met all of the criteria. Their principal limitations included a lack of documentation showing that they could obtain a representative sample and that many of them would collect of an excessive amount of activity at the design criteria. 10 refs., 4 figs., 5 tabs

  2. Environmental and effluent monitoring at Lucas Heights Science and Technology Centre, 1997

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, E L; Loosz, T; Farrar, Y

    1998-11-01

    Results are presented of environmental and effluent monitoring conducted in the vicinity of the Lucas Heights Science and Technology Centre (LHSTC) during 1997. All low-level liquid and gaseous effluent discharges complied with existing discharge authorizations and relevant environmental regulations. Potential effective doses to the general public from controlled airborne discharges from HIFAR were estimated utilising the PC-Cream atmospheric dispersion and dosimetry code. The potential effective dose to the public was estimated to be less than 0.010 mSv/year for all receptor locations on the 1.6 km buffer zone boundary around the HIFAR research reactor. This value represents 1% of the 1 mSv/year dose limit for long term exposure that is recommended by the National Health and Medical Research Council and 10% of the HIFAR dose constraint of 0.1 mSv/year 24 tabs., 7 figs.; Glossary; Appendices

  3. Environmental and effluent monitoring at ANSTO sites, 1999

    Energy Technology Data Exchange (ETDEWEB)

    Hoffman, E L; Loosz, T; Mokhber-Shahin, L

    1999-07-01

    Results are presented of environmental and effluent monitoring conducted in 1999 at the two sites owned and operated by ANSTO, at the Lucas Heights Science and Technology Centre (LHSTC) and the National Medical Cyclotron (NMC). All low-level liquid and gaseous effluent discharges complied with existing discharge authorisations and relevant environmental regulations. Potential effective doses to the general public from LHSTC controlled airborne discharges were estimated for 1999 using the PC-Cream atmospheric dispersion and dosimetry code. The potential effective doses to the public in 1999 were estimated to be less than 0.010 mSv/year for all receptor locations on the LHSTC 1.6 km buffer zone boundary or beyond. This value represents 1% of the I milli sievert (mSv) per year dose limit for long term exposure that is recommended by the National Health and Medical Research Council and 3.3% of the LHSTC site dose constraint of 0.3 mSv/year. It is concluded that there is no impact on the health of the community, staff or the environment as a consequence of operations at the Lucas Heights Science and Technology Centre or the National Medical Cyclotron (authors)

  4. Environmental and effluent monitoring at ANSTO sites 1999

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, E L; Loosz, T; Mokhber-Shahin, L [Australian Nuclear Science and Technology Organisation (ANSTO), Lucas Heights, NSW, Australia, (Australia)

    2000-07-01

    Results are presented of environmental and effluent monitoring conducted in 1999 at the two sites owned and operated by ANSTO, at the Lucas Heights Science and Technology Centre (LHSTC) and the National Medical Cyclotron (NMC). All low-level liquid and gaseous effluent discharges complied with existing discharge authorisations and relevant environmental regulations. Potential effective doses to the general public from LHSTC controlled airborne discharges were estimated for 1999 using the PC-Cream atmospheric dispersion and dosimetry code. The potential effective doses to the public in 1999 were estimated to be less than 0.010 mSv/year for all receptor locations on the LHSTC 1.6 km buffer zone boundary or beyond. This value represents 1% of the 1 millisievert (mSv) per year dose limit for long term exposure that is recommended by the National Health and Medical Research Council and 3.3% of the LHSTC site dose constraint of 0.3 mSv/year. It is concluded that there is no impact on the health of the community, staff or the environment as a consequence of operations at the Lucas Heights Science and Technology Centre or the National Medical Cyclotron.

  5. Environmental and effluent monitoring at ANSTO sites, 2000

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, E L; Loosz, T; Mokhber-Shahin, L [Australian Nuclear Science and Technology Organisation, Menai, NSW (Australia)

    2001-07-01

    Results are presented of environmental surveillance and effluent monitoring conducted in the calendar year 2000 at the two sites owned and operated by ANSTO, at the Lucas Heights Science and Technology Centre (LHSTC) and the National Medical Cyclotron (NMC). All low-level liquid and gaseous effluent discharges complied with existing discharge authorisations and relevant environmental regulations. Potential effective doses to the general public from LHSTC controlled airborne discharges were estimated for 2000 using the PC-Cream atmospheric dispersion and dosimetry code. The potential effective doses to the public in 2000 were estimated to be less than 0.01 mSv/year for all receptor locations on the LHSTC 1.6 km buffer zone boundary or beyond. This value represents 1 % of the 1 milli sievert (mSv) per year dose limit for long term exposure that is recommended by the National Health and Medical Research Council and 3.3% of the LHSTC site dose constraint of 0.3 mSv/year. It is concluded that there is no impact on the health of the community, staff or the environment as a consequence of operations at the Lucas Heights Science and Technology Centre or the National Medical Cyclotron.

  6. Environmental and effluent monitoring at ANSTO sites, 2000

    International Nuclear Information System (INIS)

    Hoffmann, E.L.; Loosz, T.; Mokhber-Shahin, L.

    2001-01-01

    Results are presented of environmental surveillance and effluent monitoring conducted in the calendar year 2000 at the two sites owned and operated by ANSTO, at the Lucas Heights Science and Technology Centre (LHSTC) and the National Medical Cyclotron (NMC). All low-level liquid and gaseous effluent discharges complied with existing discharge authorisations and relevant environmental regulations. Potential effective doses to the general public from LHSTC controlled airborne discharges were estimated for 2000 using the PC-Cream atmospheric dispersion and dosimetry code. The potential effective doses to the public in 2000 were estimated to be less than 0.01 mSv/year for all receptor locations on the LHSTC 1.6 km buffer zone boundary or beyond. This value represents 1 % of the 1 milli sievert (mSv) per year dose limit for long term exposure that is recommended by the National Health and Medical Research Council and 3.3% of the LHSTC site dose constraint of 0.3 mSv/year. It is concluded that there is no impact on the health of the community, staff or the environment as a consequence of operations at the Lucas Heights Science and Technology Centre or the National Medical Cyclotron

  7. Towards zero discharge by integrated effluent treatment approach

    International Nuclear Information System (INIS)

    Rath, Ashish Kumar; Pattnaik, Sambhu Prasad; Pati, Ganeswar; Saha, Sushant; Viswanath, Kowtha

    2014-01-01

    Heavy Water Plant, Talcher houses two Organo-phosphorus Solvent Production Plants namely, 60 MTPY TBP Plant engaged in the production of Tri-n-Butyl Phosphate and Versatile Solvent Production Plant (VSPP) capable of producing various Organo Phosphorus Solvents namely, 100 MTPY D2EHPA (Di-2-Ethyl Hexyl Phosphoric Acid), or 40 MTPY TAPO (Tri-Alkyl Phosphine Oxide) or TOPO (Tri-n-Octyl Phosphine Oxide) or DNPPA (Di-Nonyl Phenyl Phosphoric Acid). These solvents have important application for separation duties in front and back end of nuclear fuel cycle and also in conventional hydrometallurgy for separation metals like Ni, Cu, Zn, Co etc., both of these plants are first of their kind in India designed by the Heavy Water Board, Mumbai with R and D inputs from BARC. The two plants employ esterification (1) process between PCl 3 / and a suitable oxo-alcohol followed by hydrolysis, neutralization and product purification. The second and third steps find large usage of Water, which eventually surface as liquid effluent. All the gaseous emissions from plants, mostly HCl gas are traded off for Saline Water as liquid effluent by scrubbing the same with Sodium Hydroxide Solution

  8. Control verification radioactive effluent discharges to the environment

    International Nuclear Information System (INIS)

    Alvarez, D.E.; Czerniczyniec, M.A.; Amado, V.A.; Curti, A.R.; Lee Gonzáles, H.M.

    2015-01-01

    The National Law of Nuclear Activity No. 24,804 establishes that the Nuclear Regulatory Authority (ARN) will be responsible for the function of regulation and control of nuclear activity, grant, suspend and revoke licenses, permits or authorizations and to issue regulatory standards on radiation and nuclear safety. According to the latter the ARN has issued a set of rules that make up the regulatory framework for nuclear activity. This includes the standards that determine the radiological criteria for controlling the release of radioactive effluents which were established to protect members of the public. In the process of licensing a facility, the ARN determines the authorized discharge of gaseous and liquid effluents which must comply with the installation values. These annual values are understood as an operating restriction (OR) and arise from the activity of each relevant radionuclide present in the discharge. For this is taken as a reference the level of optimized discharge considering an appropriate margin of flexibility to ensure public protection without interfering with the operation of the installation. This paper presents the results of the review of the above criteria and methodology for calculating the RO adopted by the RNA present. [es

  9. Environmental and effluent monitoring at ANSTO sites 1999

    International Nuclear Information System (INIS)

    Hoffmann, E. L.; Loosz, T.; Mokhber-Shahin, L.

    2000-01-01

    Results are presented of environmental and effluent monitoring conducted in 1999 at the two sites owned and operated by ANSTO, at the Lucas Heights Science and Technology Centre (LHSTC) and the National Medical Cyclotron (NMC). All low-level liquid and gaseous effluent discharges complied with existing discharge authorisations and relevant environmental regulations. Potential effective doses to the general public from LHSTC controlled airborne discharges were estimated for 1999 using the PC-Cream atmospheric dispersion and dosimetry code. The potential effective doses to the public in 1999 were estimated to be less than 0.010 mSv/year for all receptor locations on the LHSTC 1.6 km buffer zone boundary or beyond. This value represents 1% of the 1 millisievert (mSv) per year dose limit for long term exposure that is recommended by the National Health and Medical Research Council and 3.3% of the LHSTC site dose constraint of 0.3 mSv/year. It is concluded that there is no impact on the health of the community, staff or the environment as a consequence of operations at the Lucas Heights Science and Technology Centre or the National Medical Cyclotron

  10. Environmental and effluent monitoring at ANSTO sites, 1999

    International Nuclear Information System (INIS)

    Hoffman, E.L.; Loosz, T.; Mokhber-Shahin, L.

    1999-01-01

    Results are presented of environmental and effluent monitoring conducted in 1999 at the two sites owned and operated by ANSTO, at the Lucas Heights Science and Technology Centre (LHSTC) and the National Medical Cyclotron (NMC). All low-level liquid and gaseous effluent discharges complied with existing discharge authorisations and relevant environmental regulations. Potential effective doses to the general public from LHSTC controlled airborne discharges were estimated for 1999 using the PC-Cream atmospheric dispersion and dosimetry code. The potential effective doses to the public in 1999 were estimated to be less than 0.010 mSv/year for all receptor locations on the LHSTC 1.6 km buffer zone boundary or beyond. This value represents 1% of the I milli sievert (mSv) per year dose limit for long term exposure that is recommended by the National Health and Medical Research Council and 3.3% of the LHSTC site dose constraint of 0.3 mSv/year. It is concluded that there is no impact on the health of the community, staff or the environment as a consequence of operations at the Lucas Heights Science and Technology Centre or the National Medical Cyclotron (authors)

  11. Monitoring of the release of gaseous and aerosol-bound radioactive materials. Pt. 2

    International Nuclear Information System (INIS)

    1992-01-01

    KTA 1503 contains requirements on technical installations and supplementary organizational measures considered necessary in order to monitor the release of gaseous and aerosol-bound radioactive materials. It consists of part 1: Monitoring of the release of radioactive materials together with stack gas during normal operation; part 2: Monitoring of the release of radioactive materials together with stack gas in the event of incidents; part 3: Monitoring of radioactive materials not released together with stack gas. The concept on which this rule is based is to ensure that in the case of incidents during which the result of effluent monitoring remains meaningful, such monitoring can be reliably performed. (orig./HSCH) [de

  12. Development of gaseous photomultiplier

    International Nuclear Information System (INIS)

    Tokanai, F.; Sumiyoshi, T.; Sugiyama, H.; Okada, T.

    2014-01-01

    We have been developing gaseous photomultiplier tubes (PMTs) with alkali photocathode combined with micropattern gas detectors (MPGDs). The potential advantage of the gaseous PMT is that it can achieve a very large effective area with adequate position and timing resolutions. In addition, it will be easily operated under a very high magnetic field, compared with the conventional vacuum-based PMT. To evaluate the gaseous PMTs filled with Ne and Ar based gas mixture, we have developed gaseous PMTs with an alkali photocathode combined with MPGDs such as a glass capillary plate, GEM, and Micromegas detector. We describe the recent development of the gaseous PMTs, particularly the production of the photocathode, gas gain, ion and photon feedbacks, quantum efficiency, and the characteristics in the magnetic field environment. (author)

  13. Siting considerations for radioactivity in reactor effluents during normal operation

    International Nuclear Information System (INIS)

    Graf, J.M.; Strom, P.O.

    1975-01-01

    In selecting a proper site for a nuclear power station, the consideration of radioactivity released in effluents can be handled in a straightforward manner using the U. S. Atomic Energy Commission's proposed Appendix I to 10 CFR 50, which gives numerical guidelines for design objectives for meeting the criterion ''as low as practicable'' for radioactive material in light-water-cooled nuclear power reactor effluents. By relating the release of radioactive material, the site meteorological conditions, and site boundary distance through appropriate dose models, the suitability of a given site can be determined. ''Rules of thumb'' for comparing anticipated releases to design objectives can be constructed for rapid assessment using the maximum permissible concentration values of 10 CFR 20 as dose factors. These rules of thumb tend to underpredict the allowed releases except in the case of radiocesium in liquids. For gaseous releases, these rules of thumb can be made up in convenient nomogram form for a quick assessment of allowed releases based on local site meteorological conditions. (U.S.)

  14. Continuously tritium monitoring of the pipe of liquid effluents at the Cea Cadarache

    International Nuclear Information System (INIS)

    Pira, Y.

    2004-01-01

    This report is oriented toward the radiation protection of environment that is an essential component of radiation protection. It is necessary to detect any solid, liquid or gaseous abnormal release and to find its origin. The present study bears on a detection instrument in continuously to find tritium in liquid effluents of the Cea Cadarache. After having study the functioning principle of this device, an evaluation of its performances has been realised ( back noise, yield, detection limit) and to a checking in real conditions of utilization. (N.C.)

  15. Gaseous poison injection device

    International Nuclear Information System (INIS)

    Kubota, Ryuji; Sugisaki, Toshihiko; Inada, Ikuo.

    1983-01-01

    Purpose: To rapidly control the chain reaction due to thermal neutrons in a reactor core by using gaseous poisons as back-up means for control rod drives. Constitution: Gaseous poisons having a large neutron absorption cross section are used as back-up means for control rod drives. Upon failure of control rod insertion, the gaseous poisons are injected into the lower portion of the reactor core to control the reactor power. As the gaseous poisons, vapors at a high temperature and a higher pressure than that of the coolants in the reactor core are injected to control the reactor power due to the void effects. Since the gaseous poisons thus employed rapidly reach the reactor core and form gas bubbles therein, the deccelerating effect of the thermal neutrons is decreased to reduce the chain reaction. (Moriyama, K.)

  16. Aprimorando a Gerência e o Desenvolvimento de Software com Metodologias Ágeis

    Directory of Open Access Journals (Sweden)

    Mauricio Andreazza Sganderla

    2016-07-01

    Full Text Available Este artigo aborda a melhoria da gerência e construção de software utilizando as metodologias ágeis eXtreme Programming e Scrum. São aplicadas as melhores práticas de ambas as metodologias em uma equipe de desenvolvimento de software, em um ambiente em que não havia nenhum processo bem definido de desenvolvimento de software. A escolha pelo uso das metodologias ágeis foi definida, pois atende ao dinamismo do cenário atual, requisitos voláteis, ambiente mais colaborativo e menos burocrático, tendo como objetivo principal o software em funcionamento e que realmente traga retorno ao cliente.

  17. Pedagogia de Projetos como metodologia no trabalho com a educação infantil

    OpenAIRE

    Patricia Frageri

    2016-01-01

    Este artigo teve como tema a Pedagogia de Projetos como metodologia no trabalho com a Educação Infantil e a pesquisa foi realizada na escola Gente Feliz de Sinop. A investigação teve como objetivo conhecer em que consiste a metodologia de trabalho pautada na pedagogia de projetos, e suas interfaces, no contexto da educação infantil. Os instrumentos de pesquisa foram entrevista e questionário com duas professoras. Os resultados mostram que a instituição prioriza a metodologia de trabalho por p...

  18. Report on the biological monitoring program at Paducah Gaseous Diffusion Plant December 1990 to November 1992

    Energy Technology Data Exchange (ETDEWEB)

    Kszos, L.A. [ed.

    1994-03-01

    On September 23, 1987, the Commonwealth of Kentucky Natural Resources and Environmental Protection Cabinet issued an Agreed Order that required the development of a Biological Monitoring Program (BMP) for the Paducah Gaseous Diffusion Plant (PGDP). Beginning in fall 1991, the Environmental Sciences Division (ESD) at Oak Ridge National Lab (ORNL) added data collection and report preparation to its responsibilities for the PGDP BMP. The BMP has been continued because it has proven to be extremely valuable in identifying those effluents with the potential for adversely affecting instream fauna, assessing the ecological health of receiving streams, guiding plans for remediation, and protecting human health. In September 1992, a renewed permit was issued which requires toxicity monitoring of continuous and intermittent outfalls on a quarterly basis. The BMP for PGDP consists of three major tasks: (1) effluent and ambient toxicity monitoring, (2) bioaccumulation studies, and (3) ecological surveys of stream communities. This report includes ESD/ORNL activities occurring from December 1990 to November 1992.

  19. Report on the biological monitoring program at Paducah Gaseous Diffusion Plant December 1990 to November 1992

    International Nuclear Information System (INIS)

    Kszos, L.A.

    1994-03-01

    On September 23, 1987, the Commonwealth of Kentucky Natural Resources and Environmental Protection Cabinet issued an Agreed Order that required the development of a Biological Monitoring Program (BMP) for the Paducah Gaseous Diffusion Plant (PGDP). Beginning in fall 1991, the Environmental Sciences Division (ESD) at Oak Ridge National Lab (ORNL) added data collection and report preparation to its responsibilities for the PGDP BMP. The BMP has been continued because it has proven to be extremely valuable in identifying those effluents with the potential for adversely affecting instream fauna, assessing the ecological health of receiving streams, guiding plans for remediation, and protecting human health. In September 1992, a renewed permit was issued which requires toxicity monitoring of continuous and intermittent outfalls on a quarterly basis. The BMP for PGDP consists of three major tasks: (1) effluent and ambient toxicity monitoring, (2) bioaccumulation studies, and (3) ecological surveys of stream communities. This report includes ESD/ORNL activities occurring from December 1990 to November 1992

  20. Examination of vegetation around a nuclear plant emitting gaseous fluorides in order to detect fluorine pollution

    International Nuclear Information System (INIS)

    Teulon, Francoise; Bonnaventure, J. P.

    1971-08-01

    Fluorine pollution (chronic or occasional) around a plant rejecting gaseous fluoride effluents can be detected from vegetation samples by chemical analysis. Systematic monitoring allows the effects and gravity of the pollution to be estimated. The analytical method used consists of a double distillation (in phosphoric acid and perchloric acid) followed by a spectro-colorimetric analysis (alizarine-complexon-lanthane). This method of control allows both the efficiency of the trapping installations and also the appearance of effluents at unexpected places to be checked, In the event of an accident it is possible to determine the advisability of prohibiting the consumption of locally grown produce by humans or fodder by cattle. Research conducted in order to determine the relation between visible, damage to certain vegetables (tomatoes, haricot beans and sorghum) and their fluorine contents demonstrated that such a relation appears above all at the level of the leaves; chemical analysis may thus be used to confirm or reject information obtained on the basis of visual evidence [fr

  1. Report on the biological monitoring program at Paducah Gaseous Diffusion Plant, January--December 1996

    Energy Technology Data Exchange (ETDEWEB)

    Kszos, L.A. [ed.; Konetsky, B.K.; Peterson, M.J.; Petrie, R.B.; Ryon, M.G.; Smith, J.G.; Southworth, G.R.

    1997-06-01

    On September 24, 1987, the Commonwealth of Kentucky Natural Resources and Environmental Protection Cabinet issued an Agreed Order that required the development of a Biological Monitoring Program (BMP) for the Paducah Gaseous diffusion Plant (PGDP). The PGDP BMP was conducted by the University of Kentucky Between 1987 and 1992 and by staff of the Environmental Sciences Division (ESD) at Oak Ridge National Laboratory (ORNL) from 1991 to present. The goals of BMP are to (1) demonstrate that the effluent limitations established for PGDP protect and maintain the use of Little Bayou and Big Bayou creeks for growth and propagation of fish and other aquatic life, (2) characterize potential environmental impacts, and (3) document the effects of pollution abatement facilities on stream. The BMP for PGDP consists of three major tasks: (1) effluent toxicity monitoring, (2) bioaccumulation studies, and (3) ecological surveys of stream communities (i.e., benthic macroinvertebrates and fish). This report focuses on ESD activities occurring from January 1996 to December 1996, although activities conducted outside this time period are included as appropriate.

  2. Report on the biological monitoring program at Paducah Gaseous Diffusion Plant, January - December 1996

    International Nuclear Information System (INIS)

    Kszos, L.A.; Konetsky, B.K.; Peterson, M.J.; Petrie, R.B.; Ryon, M.G.; Smith, J.G.; Southworth, G.R.

    1997-06-01

    On September 24, 1987, the Commonwealth of Kentucky Natural Resources and Environmental Protection Cabinet issued an Agreed Order that required the development of a Biological Monitoring Program (BMP) for the Paducah Gaseous diffusion Plant (PGDP). The PGDP BMP was conducted by the University of Kentucky Between 1987 and 1992 and by staff of the Environmental Sciences Division (ESD) at Oak Ridge National Laboratory (ORNL) from 1991 to present. The goals of BMP are to (1) demonstrate that the effluent limitations established for PGDP protect and maintain the use of Little Bayou and Big Bayou creeks for growth and propagation of fish and other aquatic life, (2) characterize potential environmental impacts, and (3) document the effects of pollution abatement facilities on stream. The BMP for PGDP consists of three major tasks: (1) effluent toxicity monitoring, (2) bioaccumulation studies, and (3) ecological surveys of stream communities (i.e., benthic macroinvertebrates and fish). This report focuses on ESD activities occurring from January 1996 to December 1996, although activities conducted outside this time period are included as appropriate

  3. Environmental and effluent monitoring at ANSTO sites, 2001

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, E L; Loosz, T

    2002-07-01

    Results are presented of environmental surveillance and effluent monitoring conducted in the calendar year 2001 at the two sites owned and operated by ANSTO at the Lucas Heights Science and Technology Centre (LHSTC) and the National Medical Cyclotron (NMC). All low-level liquid and gaseous effluent discharges complied with existing discharge authorisations and relevant environmental regulations. Potential effective doses to the general public from LHSTC-controlled airborne discharges were estimated for 2001 using the PC-Cream atmospheric dispersion and dosimetry code. The potential effective doses to the public in 2001 were estimated to be less than 0.01 mSv/year for all receptor locations on the LHSTC 1.6 km buffer zone boundary or beyond. This is well below the ALARA objective of 0.02 mSv per year for off-site doses that ANSTO has set and much lower than the public dose limit of 1 mSv per year (above natural background and medical doses) and the natural background dose in Australia of 1.5 mSv per year (Webb et al; 1999). It is concluded that there is no impact on the health of the community as a consequence of operations at the Lucas Heights Science and Technology Centre or the National Medical Cyclotron.

  4. Environmental and effluent monitoring at ANSTO sites, 2001

    International Nuclear Information System (INIS)

    Hoffmann, E.L.; Loosz, T.

    2002-01-01

    Results are presented of environmental surveillance and effluent monitoring conducted in the calendar year 2001 at the two sites owned and operated by ANSTO at the Lucas Heights Science and Technology Centre (LHSTC) and the National Medical Cyclotron (NMC). All low-level liquid and gaseous effluent discharges complied with existing discharge authorisations and relevant environmental regulations. Potential effective doses to the general public from LHSTC-controlled airborne discharges were estimated for 2001 using the PC-Cream atmospheric dispersion and dosimetry code. The potential effective doses to the public in 2001 were estimated to be less than 0.01 mSv/year for all receptor locations on the LHSTC 1.6 km buffer zone boundary or beyond. This is well below the ALARA objective of 0.02 mSv per year for off-site doses that ANSTO has set and much lower than the public dose limit of 1 mSv per year (above natural background and medical doses) and the natural background dose in Australia of 1.5 mSv per year (Webb et al; 1999). It is concluded that there is no impact on the health of the community as a consequence of operations at the Lucas Heights Science and Technology Centre or the National Medical Cyclotron

  5. RUP-pe : uma metodologia ágil, baseada no RUP e no TSP, para pequenas equipes

    OpenAIRE

    Pedro Carvalho de Oliveira, Joaquim

    2003-01-01

    Pesquisas recentes têm mostrado que projetos de software de curta duração e que utilizam equipes pequenas possuem maiores chances de sucesso. Entretanto, a escolha da metodologia a ser utilizada neste tipo de projeto deve levar em consideração suas características, como a comunicação facilitada e o menor grau de formalismo nos artefatos. Para se utilizar metodologias de desenvolvimento pesadas, como o RUP e o OPEN, deve-se fazer uma adaptação da metodologia escolhida, pois elas se propõem ser...

  6. A METODOLOGIA ATIVA COMO PROPOSTA PARA O ENSINO DE CIÊNCIAS

    OpenAIRE

    Segura, Eduardo; Kalhil, Josefina Barrera

    2015-01-01

    Este artigo resgata a discussão a respeito da utilização das metodologias ativas no Ensino de Ciências. O seu objetivo consiste em apresentar de forma clara e sucinta a características e a estrutura de três estratégias de ensino baseadas nas metodologias ativas. O embasamento do artigo está em Galiazzi (2000), Pozo e Crespo (2009), Oliveira (2013), Delizoicov, Angotti e Pernambuo (2009), El chaer (2013), Conrado (2013), dentre outros. O percurso metodológico está ancorado na pesquisa bibliogr...

  7. Significance of population centers as sources of gaseous and dissolved PAHs in the lower Great Lakes.

    Science.gov (United States)

    McDonough, Carrie A; Khairy, Mohammed A; Muir, Derek C G; Lohmann, Rainer

    2014-07-15

    Polyethylene passive samplers (PEs) were used to measure concentrations of gaseous and dissolved polycyclic aromatic hydrocarbons (PAHs) in the air and water throughout the lower Great Lakes during summer and fall of 2011. Atmospheric Σ15PAH concentrations ranged from 2.1 ng/m3 in Cape Vincent (NY) to 76.4 ng/m3 in downtown Cleveland (OH). Aqueous Σ18PAH concentrations ranged from 2.4 ng/L at an offshore Lake Erie site to 30.4 ng/L in Sheffield Lake (OH). Gaseous PAH concentrations correlated strongly with population within 3-40 km of the sampling site depending on the compound considered, suggesting that urban centers are a primary source of gaseous PAHs (except retene) in the lower Great Lakes region. The significance of distant population (within 20 km) versus local population (within 3 km) increased with subcooled liquid vapor pressure. Most dissolved aqueous PAHs did not correlate significantly with population, nor were they consistently related to river discharge, wastewater effluents, or precipitation. Air-water exchange calculations implied that diffusive exchange was a source of phenanthrene to surface waters, while acenaphthylene volatilized out of the lakes. Comparison of air-water fluxes with temperature suggested that the significance of urban centers as sources of dissolved PAHs via diffusive exchange may decrease in warmer months.

  8. Environmental and effluent monitoring at Lucas Heights Science and Technology Centre, 1998

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, E L; Loosz, T; Farrar, Y; Mokhber-Shahin, L

    1999-07-01

    Results are presented of environmental and effluent monitoring conducted in the vicinity of the Lucas Heights Science and Technology Centre (LHSTC) during 1998. All low-level liquid and gaseous effluent discharges complied with existing discharge authorizations and relevant environmental regulations. Potential effective doses to the general public from controlled airborne discharges from HIFAR were estimated utilising the PC-Cream atmospheric dispersion and dosimetry code. The potential effective dose to the public was estimated to be less than 0.010 mSv/year for all receptor locations on the 1.6 km buffer zone boundary around the HIFAR research reactor. This value represents 1% of the 1 mSv/year dose limit for long term exposure that is recommended by the National Health and Medical Research Council and 3.3% of the site dose constraint of 0.3 mSv/year approved by the Nuclear Safety Bureau. It is concluded that there is no impact on the health of the community, staff or the environment as a consequence of operations at the LHSTC.

  9. Environmental and effluent monitoring at Lucas Heights Science and Technology Centre, 1998

    International Nuclear Information System (INIS)

    Hoffmann, E.L.; Loosz, T.; Farrar, Y.; Mokhber-Shahin, L.

    1999-01-01

    Results are presented of environmental and effluent monitoring conducted in the vicinity of the Lucas Heights Science and Technology Centre (LHSTC) during 1998. All low-level liquid and gaseous effluent discharges complied with existing discharge authorizations and relevant environmental regulations. Potential effective doses to the general public from controlled airborne discharges from HIFAR were estimated utilising the PC-Cream atmospheric dispersion and dosimetry code. The potential effective dose to the public was estimated to be less than 0.010 mSv/year for all receptor locations on the 1.6 km buffer zone boundary around the HIFAR research reactor. This value represents 1% of the 1 mSv/year dose limit for long term exposure that is recommended by the National Health and Medical Research Council and 3.3% of the site dose constraint of 0.3 mSv/year approved by the Nuclear Safety Bureau. It is concluded that there is no impact on the health of the community, staff or the environment as a consequence of operations at the LHSTC

  10. Metodologia jurídica Europeia e Mercosulista: considerações fundamentais

    Directory of Open Access Journals (Sweden)

    Augusto Jaeger Junior

    2015-12-01

    Full Text Available O presente artigo discute a existência de uma metodologia jurídica no Mercosul, um bloco econômico intergovernamental, tendo por base a elogiável experiência supranacional, desenvolvida na União Europeia. Explorado é o fato de acreditar-se ser adequado o Mercosul restringir-se, no presente momento e estágio da integração, ao seu modelo original. Para tanto, em um primeiro momento, observa-se qual é o direito que o Mercosul tem, depois, quais são as características do direito da União Europeia, bem como a existência de uma verdadeira metodologia jurídica europeia, tudo isso com o propósito de ser, ao seu final, proposta a construção de uma metodologia jurídica mercosulista. É necessário admitir que ainda muito dela não existe, mas isso não quer dizer que a europeia possa ou deva ser transferida para o Mercosul.

  11. Metodologia de avaliação e desenvolvimento de grupos de alto desempenho

    Directory of Open Access Journals (Sweden)

    Ana Cristina Carneiro

    2008-11-01

    Full Text Available Este artigo discute a fundamentação teórica do Projeto de Avaliação e Desenvolvimento de Grupos de Alto Desempenho, concebido com base na metodologia da Meta-aprendizagem, e no Modelo Evolutivo, estendido à luz da Teoria da Complexidade. Visa ao desenvolvimento e aplicação de uma metodologia de avaliação/constituição de grupos de alto desempenho no ambiente de pesquisa e pós-graduação. A metodologia proposta validada empiricamente teve base no aproveitamento das virtudes e potencialidades das teorias que lhe deram origem. É destinado aos docentes e pesquisadores de vários campos do conhecimento, bem como aos dirigentes de instituições de educação superior e de pesquisa.

  12. Gaseous Matter

    CERN Document Server

    Angelo, Joseph A

    2011-01-01

    aseous Matter focuses on the many important discoveries that led to the scientific interpretation of matter in the gaseous state. This new, full-color resource describes the basic characteristics and properties of several important gases, including air, hydrogen, helium, oxygen, and nitrogen. The nature and scope of the science of fluids is discussed in great detail, highlighting the most important scientific principles upon which the field is based. Chapters include:. Gaseous Matter An Initial Perspective. Physical Characteristics of Gases. The Rise of the Science of Gases. Kinetic Theory of

  13. Report on the biological monitoring program at Paducah Gaseous Diffusion Plant December 1993 to December 1994

    Energy Technology Data Exchange (ETDEWEB)

    Kszos, L.A. [ed.

    1996-05-01

    On September 24, 1987, the Commonwealth of Kentucky Natural Resources and Environmental Protection Cabinet issued an Agreed Order that required the development of a Biological Monitoring Program (BMP) for the Paducah Gaseous Diffusion Plant (PGDP). The PGDP BMP was implemented in 1987 by the University of Kentucky. Research staff of the Environmental Sciences Division (ESD) at Oak Ridge National Laboratory (ORNL) served as reviewers and advisers to the University of Kentucky. Beginning in fall 1991, ESD added data collection and report preparation to its responsibilities for the PGDP BMP. The goals of BMP are to (1) demonstrate that the effluent limitations established for PGDP protect and maintain the use of Little Bayou and Big Bayou creeks for growth and propagation of fish and other aquatic life, (2) characterize potential environmental impacts, (3) document the effects of pollution abatement facilities on stream biota, and (4) recommend any program improvements that would increase effluent treatability. In September 1992, a renewed Kentucky Pollutant Discharge Elimination System (KPDES) permit was issued to PGDP. The BMP for PGDP consists of three major tasks: (1) effluent and ambient toxicity monitoring, (2) bioaccumulation studies, and (3) ecological surveys of stream communities (i.e., benthic macroinvertebrates and fish). This report includes ESD activities occurring from December 1993 to December 1994, although activities conducted outside this time period are included as appropriate.

  14. Report on the biological monitoring program at Paducah Gaseous Diffusion Plant December 1993 to December 1994

    International Nuclear Information System (INIS)

    Kszos, L.A.

    1996-05-01

    On September 24, 1987, the Commonwealth of Kentucky Natural Resources and Environmental Protection Cabinet issued an Agreed Order that required the development of a Biological Monitoring Program (BMP) for the Paducah Gaseous Diffusion Plant (PGDP). The PGDP BMP was implemented in 1987 by the University of Kentucky. Research staff of the Environmental Sciences Division (ESD) at Oak Ridge National Laboratory (ORNL) served as reviewers and advisers to the University of Kentucky. Beginning in fall 1991, ESD added data collection and report preparation to its responsibilities for the PGDP BMP. The goals of BMP are to (1) demonstrate that the effluent limitations established for PGDP protect and maintain the use of Little Bayou and Big Bayou creeks for growth and propagation of fish and other aquatic life, (2) characterize potential environmental impacts, (3) document the effects of pollution abatement facilities on stream biota, and (4) recommend any program improvements that would increase effluent treatability. In September 1992, a renewed Kentucky Pollutant Discharge Elimination System (KPDES) permit was issued to PGDP. The BMP for PGDP consists of three major tasks: (1) effluent and ambient toxicity monitoring, (2) bioaccumulation studies, and (3) ecological surveys of stream communities (i.e., benthic macroinvertebrates and fish). This report includes ESD activities occurring from December 1993 to December 1994, although activities conducted outside this time period are included as appropriate

  15. Metodologia para análise e ampliação da competitividade empresarial

    Directory of Open Access Journals (Sweden)

    Jose Celso Contador

    2006-01-01

    Full Text Available O artigo apresenta uma nova metodologia para analisar e explicar a competitividade de um conjunto de empresas e para aumentar a competitividade de uma empresa. Essa metodologia, baseada no modelo de campos e armas da competição, separa a estratégia competitiva de negócio da estratégia competitiva operacional. A primeira é constituída por alguns dos 15 campos da competição, e a segunda, pelas armas da competição. A metodologia utiliza variáveis matemáticas para explicar a competitividade empresarial. A análise da influência das estratégias é feita pelo teste estatístico não-paramétrico de Wilcoxon-Mann-Whitney, teste correlação de Pearson. A metodologia foi aplicada às empresas do pólo têxtil de Americana, donde inúmeras conclusões foram extraídas, entre elas: não é a estratégia de negócio que explica a competitividade empresarial, mas sim as operacionais; para ampliar sua competitividade, a empresa deve aumentar seu foco nas armas que são relevantes para os campos onde decidiu competir.

  16. Derived release limits for radionuclides in airborne and liquid effluents for the Whiteshell Nuclear Research Establishment and errata

    International Nuclear Information System (INIS)

    Lemire, A.E.

    1989-08-01

    Radionuclides released to the environment may cause external and internal radiation exposure to man via a number of potential pathways. The resulting radiation dose due to such releases from any operating facility must be kept below dose limits specified in the regulations issued by the Atomic Energy Control Board of Canada. At the Whiteshell Nuclear Research Establishment (WNRE), there is one primary source of liquid effluent to the Winnipeg River via the process water outfall. There are five sources of gaseous effluents: the WR-1 stack; the incinerator stack in the waste management area; the active laboratories building (including the hot cells); the Active-Liquid Waste Treatment Centre; and the compactor-baler in the Waste Management Area. This report presents the methodology and models used to calculate the maximum permissible release rates of radionuclides for each of these sources

  17. Turbulent transfer characteristics of radioiodine effluents from air to grass

    Energy Technology Data Exchange (ETDEWEB)

    Markee, E. H. [ARFRO, Environmental Science Services Administration, Idaho Falls, Idaho (United States)

    1967-07-01

    A total of 20 controlled field releases of radioiodine have been performed at the National Reactor Testing Station in Idaho as a portion of a program to study the transmission of gaseous radioiodine through the air-vegetation-cow-milk-human chain. Most of the releases were conducted over typical pasture grasses during different wind and stability conditions. Radioiodine adherence to grass and carbon plates was measured during most of the tests. Vertical air concentration profiles and turbulence parameters were measured to determine flux characteristics. Analysis of the data reveals the complex interdisciplinary nature of transfer of radioiodine from air to a natural surface. The data are in reasonable agreement with the deposition models of Sheppard and Chamberlain when corrections for the physical and biological receptiveness of the grass and grass density are made. The average ratios of momentum to mass flux were found to be 0.9 in stable conditions and 1.4 in unstable conditions. These ratios demonstrate the effect on mass flux in the lowest 4m by a surface that acts as a partial sink for gaseous effluents. This series of releases indicates the need for further research on the biological receptiveness of grass and turbulent transfer within a grass canopy. (author)

  18. Radiological safety system based on real-time tritium-in-air monitoring indoor and in effluents

    International Nuclear Information System (INIS)

    Bidica, Nicolae; Sofalca, Nicolae; Balteanu, Ovidiu-Ioan; Stefan, Ioana-Iuliana

    2007-01-01

    In this paper we describe an improved real-time tritium monitoring system designed for Heavy Water Detritiation Pilot Plant of National Institute for Cryogenics and Isotopes Separation, Rm. Valcea, Romania. The system consists of three fixed tritium-in-air monitors which measure continuously tritium-in-air concentration (in both species: vapour and gas) in working areas and gaseous effluents. Portable tritium monitors with ionization chamber, and tritium-in-air collector combined with liquid scintillation counter method are also used to supplement fixed instrument measurements. The main functions of tritium monitoring system are: to measure tritium-in air concentration in working areas and gaseous effluents; to alarm the personnel if tritium concentration thresholds are exceeded; to integrate tritium activity released to the environment during a week and to cut off normal ventilation when the activity threshold is exceeded and start the air cleaning system. Now, several especial functions have been added, so that by using appropriate conversion factors, the tritium monitoring system is able to estimate the effective dose rate before starting an activity into the monitored area, during this activity, or soon as the activity was finished. Another new function has been added by coupling tritium-in-air monitoring system with control access system. This is very useful for quick estimation of tritium doses. For routine dosimetric survey, one the internal dose for individuals by measuring tritium in urine is estimated. With all these features our tritium monitoring system is really a safety system for personnel and for environment. (authors)

  19. Metodologia para análise de adaptabilidade e estabilidade por meio de regressão quantílica

    Directory of Open Access Journals (Sweden)

    Laís Mayara Azevedo Barroso

    2015-04-01

    Full Text Available O objetivo deste trabalho foi desenvolver e validar uma metodologia de análise da adaptabilidade e da estabilidade fenotípica baseada em regressão quantílica (RQ. Para tanto, foram simulados valores fenotípicos com distribuição simétrica e com distribuição assimétrica à direita e à esquerda, com ou sem a presença de "outliers". A metodologia proposta foi aplicada a um conjunto de dados provenientes de um experimento com 92 genótipos de alfafa (Medicago sativa, avaliados em 20 ambientes, e comparada às metodologias de Eberhart & Russell e de regressão não paramétrica. A metodologia da RQ proporcionou resultados iguais ou superiores aos obtidos com as metodologias alternativas avaliadas. No entanto, a ocorrência de resultados discordantes entre as metodologias evidencia a importância de se avaliar a simetria na distribuição dos valores fenotípicos. Para distribuições simétricas, na presença de "outliers", deve-se utilizar a RQ com valor de quantil estimado (τ em 0,50; na ausência de "outliers", pode-se utilizar tanto a metodologia de Eberhart & Russell quanto a RQ (τ = 0,50. Para distribuições assimétricas, indica-se o uso da RQ com τ = 0,25, para assimetria à direita, e com τ = 0,75, para assimetria à esquerda, independentemente da presença de "outliers".

  20. ANÁLISE DESCRITIVA: COMPARAÇÃO ENTRE METODOLOGIAS

    Directory of Open Access Journals (Sweden)

    Valéria Paula Rodrigues Minim

    2010-06-01

    Full Text Available Métodos sensoriais descritivos são de grande importância na indústria de alimentos para definir a qualidade sensorial de um produto. A análise descritiva quantitativa (ADQ é um método muito usado para identificar e quantficar os atributos sensoriais de alimentos. As etapas para realização da ADQ são: recrutamento e pré-seleção dos candidatos à julgadores, levantamento e descrição dos atributos, treinamento e seleção final dos julgadores e avaliação dos produtos. Visto que a ADQ requer treinamento longo dos julgadores, uma nova metodologia descritiva por ordenação (ADO foi desenvolvida recentemente , na qual algumas etapas são semelhantes à ADQ, porém o treinamento e a seleção final dos julgadores não acontecem e a avaliação dos produtos é realizada por ordenação da intensidade dos atributos, sendo a ADO um método mais econômico e rápido. O presente trabalho comparou a nova metodologia descritiva (ADO com o método tradicionalmente utilizado, a ADQ, por meio da descrição sensorial de quatro marcas de requeijão cremoso. Os atributos que caracterizaram os produtos foram: cor, aroma e sabor característicos, gosto doce, gosto salgado, sabor de ranço, consistência e viscosidade. Observou-se correlação significativa (p<0,05 entre as metodologias para 62,5% dos atributos avaliados. Assim, quando o objetivo é identificar diferenças sensoriais mais acentuadas a ADO pode ser usada em substituição a ADQ.

  1. Dispersion of effluents in the atmosphere; Dispersion des effluents dans l`atmosphere

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-12-31

    This conference day was organized by the `convection` section of the French association of thermal engineers with the support of the environment and energy mastery agency (ADEME). This book of proceedings contains 10 papers entitled: `physical modeling of atmospheric dispersion in wind tunnels. Some industrial examples`; `modeling of the noxious effects of a fire on the environment of an industrial site: importance of thermal engineering related hypotheses`; `atmospheric diffusion of a noxious cloud: fast evaluation method of safety areas around refrigerating installations that use ammonia`; `modeling of atmospheric flows in urban areas in order to study the dispersion of pollutants`; `use of a dispersion parameter to characterize the evolution of a diffusion process downstream of a linear source of passive contaminant placed inside a turbulent boundary layer`; `elements of reflexion around the development of an analytical methodology applied to the elaboration of measurement strategies of air quality in ambient and outdoor atmospheres around industrial sites`; `state-of-the-art about treatment techniques for VOC-rich gaseous effluents`; `characteristics of the time variation of the atmospheric pollution in the Paris region and visualization of its space distribution`; `mass-spectrometry for the measurement of atmospheric pollutants`; `volume variations in natural convection turbulence`. (J.S.)

  2. Dispersion of effluents in the atmosphere; Dispersion des effluents dans l`atmosphere

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-31

    This conference day was organized by the `convection` section of the French association of thermal engineers with the support of the environment and energy mastery agency (ADEME). This book of proceedings contains 10 papers entitled: `physical modeling of atmospheric dispersion in wind tunnels. Some industrial examples`; `modeling of the noxious effects of a fire on the environment of an industrial site: importance of thermal engineering related hypotheses`; `atmospheric diffusion of a noxious cloud: fast evaluation method of safety areas around refrigerating installations that use ammonia`; `modeling of atmospheric flows in urban areas in order to study the dispersion of pollutants`; `use of a dispersion parameter to characterize the evolution of a diffusion process downstream of a linear source of passive contaminant placed inside a turbulent boundary layer`; `elements of reflexion around the development of an analytical methodology applied to the elaboration of measurement strategies of air quality in ambient and outdoor atmospheres around industrial sites`; `state-of-the-art about treatment techniques for VOC-rich gaseous effluents`; `characteristics of the time variation of the atmospheric pollution in the Paris region and visualization of its space distribution`; `mass-spectrometry for the measurement of atmospheric pollutants`; `volume variations in natural convection turbulence`. (J.S.)

  3. Effluent standards

    Energy Technology Data Exchange (ETDEWEB)

    Geisler, G C [Pennsylvania State University (United States)

    1974-07-01

    At the conference there was a considerable interest in research reactor standards and effluent standards in particular. On the program, this is demonstrated by the panel discussion on effluents, the paper on argon 41 measured by Sims, and the summary paper by Ringle, et al. on the activities of ANS research reactor standards committee (ANS-15). As a result, a meeting was organized to discuss the proposed ANS standard on research reactor effluents (15.9). This was held on Tuesday evening, was attended by members of the ANS-15 committee who were present at the conference, participants in the panel discussion on the subject, and others interested. Out of this meeting came a number of excellent suggestions for changes which will increase the utility of the standard, and a strong recommendation that the effluent standard (15.9) be combined with the effluent monitoring standard. It is expected that these suggestions and recommendations will be incorporated and a revised draft issued for comment early this summer. (author)

  4. Gaseous waste processing facility

    International Nuclear Information System (INIS)

    Konno, Masanobu; Uchiyama, Yoshio; Suzuki, Kunihiko; Kimura, Masahiro; Kawabe, Ken-ichi.

    1992-01-01

    Gaseous waste recombiners 'A' and 'B' are connected in series and three-way valves are disposed at the upstream and the downstream of the recombiners A and B, and bypass lines are disposed to the recombiners A and B, respectively. An opening/closing controller for the three-way valves is interlocked with a hydrogen densitometer disposed to a hydrogen injection line. Hydrogen gas and oxygen gas generated by radiolysis in the reactor are extracted from a main condenser and caused to flow into a gaseous waste processing system. Gaseous wastes are introduced together with overheated steams to the recombiner A upon injection of hydrogen. Both of the bypass lines of the recombiners A and B are closed, and recombining reaction for the increased hydrogen gas is processed by the recombiners A and B connected in series. In an operation mode not conducting hydrogen injection, it is passed through the bypass line of the recombiner A and processed by the recombiner B. With such procedures, the increase of gaseous wastes due to hydrogen injection can be coped with existent facilities. (I.N.)

  5. General principles governing sampling and measurement techniques for monitoring radioactive effluents from nuclear facilities

    International Nuclear Information System (INIS)

    Fitoussi, L.

    1978-01-01

    An explanation is given of the need to monitor the release of radioactive gases and liquid effluents from nuclear facilities, with particular emphasis on the ICRP recommendations and on the interest in this problem shown by the larger international organizations. This is followed by a description of the classes of radionuclides that are normally monitored in this way. The characteristics of monitoring 'in line' and 'by sample taking' are described; the disadvantages of in line monitoring and the problem of sample representativity are discussed. There follows an account of the general principles for measuring gaseous and liquid effluents that are applied in the techniques normally employed at nuclear facilities. Standards relating to the specifications for monitoring instruments are at present being devised by the International Electrotechnical Commission, and there are still major differences in national practices, at least as far as measurement thresholds are concerned. In conclusion, it is shown that harmonization of practices and standardization of equipment would probably help to make international relations in the field more productive. (author)

  6. Definição de metadados para recursos informacionais: apresentação da metodologia BEAM

    Directory of Open Access Journals (Sweden)

    Plácida Leopoldina Ventura Amorim da Costa Santos

    2014-02-01

    Full Text Available Introdução: No ambiente digital, os metadados influenciam tanto no acesso aos dados quanto na recuperação da informação e são utilizados como ferramenta/elementos de busca para facilitar a localização de recursos na Web. Objetivo: Nessa perspectiva, o objetivo é apresentar a metodologia BEAM, desenvolvida na Biblioteca de Estudos e Aplicação de Metadados, do Grupo de Pesquisa – Novas Tecnologias em Informação, da UNESP e utilizada para definir os metadados para a descrição de recursos informacionais. Metodologia: Nesse sentido, a metodologia utilizada para a construção da pesquisa é exploratória e bibliográfica e foi desenvolvida tendo como base teórica o método de Chuttur (2011 e o ciclo de vida dos dados do DataONE (2012 e ainda o ciclo PDCA e a ferramenta 5W1H. Resultados: As sete etapas da metodologia são apresentadas e também as orientações necessárias para sua aplicação. Conclusões: Conclui-se apontando que a metodologia BEAM pode ser adotada por bibliotecas, no processo de construção de catálogos voltados para o atendimento das necessidades dos usuários.

  7. Facility effluent monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Gleckler, B.P.

    1995-06-01

    This section of the 1994 Hanford Site Environmental Report summarizes the facility effluent monitoring programs and provides an evaluation of effluent monitoring data. These evaluations are useful in assessing the effectiveness of effluent treatment and control systems, as well as management practices.

  8. Order of 30 March 1988 on licensing of gaseous radioactive effluent releases by the Fontenay-aux-Roses Nuclear Research Centre

    International Nuclear Information System (INIS)

    1988-01-01

    This Decree prescribes the documents and information the Fontenay-aux-Roses Nuclear Research Centre must provide to the Central Service for Protection against Ionizing Radiation (SCPRI) and lays down the permissible effluent release limits for the Centre [fr

  9. Elimination of effluents and wastes contaminated by radionuclides produced in installations authorized on the account of the Public Health Code - ASN guide nr 18 - Release of the 26/01/2012

    International Nuclear Information System (INIS)

    2012-01-01

    This document aims at specifying the modalities of application of a decision taken by the ASN in January 2008 regarding the technical rules which the elimination of effluents and wastes contaminated by radionuclides must comply with. First, it describes the objective of the 'waste zoning' concept. Then, it addresses the management of contaminated wastes: general rules, wastes contaminated by radionuclides of very short period (less than 100 days) and of period longer than 100 days, and the management of wastes with 'hybrid risks'. It addresses the management of contaminated effluents: radioactive liquid effluent with a period either shorter or longer than 100 days, radioactive gaseous effluents. It addresses the warehousing conditions (premise design, exploitation rules). The other parts deal with the convention between several establishments within a same site (notably in the case of nuclear medicine departments), with the management plan, and with the agenda for the implementation of the ASN decision

  10. Isotope exchange between gaseous hydrogen and uranium hydride powder

    International Nuclear Information System (INIS)

    Shugard, Andrew D.; Buffleben, George M.; Johnson, Terry A.; Robinson, David B.

    2014-01-01

    Highlights: • Isotope exchange between hydrogen gas and uranium hydride powder can be rapid and reversible. • Gas–solid exchange rate is controlled by transport within ∼0.7 μm hydride particles. • Gas chromatographic separation of hydrogen isotopes using uranium hydride is feasible. - Abstract: Isotope exchange between gaseous hydrogen and solid uranium hydride has been studied by flowing hydrogen (deuterium) gas through packed powder beds of uranium deuteride (hydride). We used a residual gas analyzer system to perform real-time analysis of the effluent gas composition. We also developed an exchange and transport model and, by fitting it to the experimental data, extracted kinetic parameters for the isotope exchange reaction. Our results suggest that, from approximately 70 to 700 kPa and 25 to 400 °C, the gas-to-solid exchange rate is controlled by hydrogen and deuterium transport within the ∼0.7 μm diameter uranium hydride particles. We use our kinetic parameters to show that gas chromatographic separation of hydrogen and deuterium using uranium hydride could be feasible

  11. Examination of vegetation around a nuclear plant emitting gaseous fluorides in order to detect fluorine pollution; Utilisation des vegetaux pour detecter la pollution fluoree autour d'une usine susceptible d'emettre des effluents gazeux fluores

    Energy Technology Data Exchange (ETDEWEB)

    Teulon, Francoise; Bonnaventure, J. P. [Commissariat a l' energie atomique et aux energies alternatives - CEA, Centre de Pierrelatte, Section de Protection contre les Radiations (France)

    1971-08-15

    Fluorine pollution (chronic or occasional) around a plant rejecting gaseous fluoride effluents can be detected from vegetation samples by chemical analysis. Systematic monitoring allows the effects and gravity of the pollution to be estimated. The analytical method used consists of a double distillation (in phosphoric acid and perchloric acid) followed by a spectro-colorimetric analysis (alizarine-complexon-lanthane). This method of control allows both the efficiency of the trapping installations and also the appearance of effluents at unexpected places to be checked, In the event of an accident it is possible to determine the advisability of prohibiting the consumption of locally grown produce by humans or fodder by cattle. Research conducted in order to determine the relation between visible, damage to certain vegetables (tomatoes, haricot beans and sorghum) and their fluorine contents demonstrated that such a relation appears above all at the level of the leaves; chemical analysis may thus be used to confirm or reject information obtained on the basis of visual evidence [French] La detection d'une pollution fluoree (chronique ou accidentelle) autour d'une usine susceptible d'emettre des effluents gazeux fluores peut etre avantageusement realisee par un reseau de prelevements vegetaux suivis de dosages chimiques. Une surveillance systematique permet une evaluation des consequences et du degre de gravite de la pollution. La methode d'analyse consiste en une double distillation (dans l'acide phosphorique et l'acide perchlorique) suivie d'une spectrocolorimetrie (alizarine-complexon-lanthane). Ce mode de controle permet non seulement de verifier si les installations de piegeage sont efficaces mais egalement de localiser des points d'emission imprevus. En cas d'accident, on peut egalement juger de l'opportunite d'interdire la consommation des legumes par les habitants ou du fourrage par le betail des environs. Enfin, des etudes experimentales ont ete realisees pour

  12. Control of effluents and environmental surveillance of the CEA centres. 1997 status; Controle des rejets et surveillance de l'environnement des centres CEA. Bilan 1997

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-06-01

    The environmental quality in the vicinity of CEA facilities is a major concern of the safety policy of the CEA. The aim of this document is to inform the public about the gaseous and liquids radioactive effluents released by the CEA centres under the permission of the ministry. It provides a status of the effluents and of the radioactivity levels measured near the CEA centres in 1997, using air, water, vegetation and milk samples. A comparison is made with the measurements performed during the 1993-1996 period. The data presented comes from the regulatory registers transmitted to the agency for the protection against ionizing radiations (OPRI) which belongs to the ministry of health. (J.S.)

  13. ENSINO DE BOTÂNICA: METODOLOGIAS, CONCEPÇÕES DE ENSINO E CURRÍCULO

    OpenAIRE

    Dutra, Ana Paula; Güllich, Roque Ismael da Costa

    2016-01-01

    Este trabalho busca apresentar uma pesquisa documental, através de análise temática de conteúdos, referente às diferentes metodologias e categorias de currículo que perpassam/embasam o ensino de botânica no Brasil. Assim como, discutir algumas das metodologias encontradas em trabalhos publicados na sessão de ensino, nos anais dos Congressos Brasileiros de Botânica, promovidos pela Sociedade Brasileira de Botânica entre os anos de 2004 até 2013, a saber: Trilha ecológica, atividades práticas, ...

  14. Gaseous radioactive waste processing system

    International Nuclear Information System (INIS)

    Onizawa, Hideo.

    1976-01-01

    Object: To prevent explosion of hydrogen gas within gaseous radioactive waste by removing the hydrogen gas by means of a hydrogen absorber. Structure: A coolant extracted from a reactor cooling system is sprayed by nozzle into a gaseous phase (hydrogen) portion within a tank, thus causing slipping of radioactive rare gas. The gaseous radioactive waste rich in hydrogen, which is purged in the tank, is forced by a waste gas compressor into a hydrogen occlusion device. The hydrogen occlusion device is filled with hydrogen occluding agents such as Mg, Mg-Ni alloy, V-Nb alloy, La-Ni alloy and so forth, and hydrogen in the waste gas is removed through reaction to produce hydrogen metal. The gaseous radioactive waste, which is deprived of hydrogen and reduced in volume, is stored in an attenuation tank. The hydrogen stored in the hydrogen absorber is released and used again as purge gas. (Horiuchi, T.)

  15. Mass spectrometric study of thermodynamic properties of gaseous lead tellurates. Estimation of formation enthalpies of gaseous lead polonates

    Energy Technology Data Exchange (ETDEWEB)

    Shugurov, S.M., E-mail: s.shugurov@spbu.ru; Panin, A.I.; Lopatin, S.I.; Emelyanova, K.A.

    2016-10-15

    Gaseous reactions involving lead oxides, tellurium oxide and lead tellurates were studied by the Knudsen effusion mass spectrometry. Equilibrium constants and reaction enthalpies were evaluated. Structures, molecular parameters and thermodynamic functions of gaseous PbTeO{sub 3} and Pb{sub 2}TeO{sub 4} were calculated by quantum chemistry methods. The formation enthalpies Δ{sub f}H{sup 0} (298.15) = −294 ± 13 for gaseous PbTeO{sub 3} and Δ{sub f}H{sup 0} (298.15) = −499 ± 12 for gaseous Pb{sub 2}TeO{sub 4} were obtained. On the base of these results the formation enthalpies of gaseous PbPoO{sub 3} and Pb{sub 2}PoO{sub 4} were estimated as −249 ± 34 and −478 ± 38, respectively. - Highlights: • Gaseous lead tellurates PbTeO{sub 3}, Pb{sub 2}TeO{sub 4} were discovered. • Their thermodynamic properties were studied using both high temperature mass spectrometry and quantum chemistry computations. • The obtained data allows to predict the formation enthalpies of gaseous lead polonates PbPoO{sub 3}, Pb{sub 2}PoO{sub 4}.

  16. 7th International Symposium on Gaseous Dielectrics

    CERN Document Server

    James, David

    1994-01-01

    The Seventh International Symposium on Gaseous Dielectrics was held in Knoxville, Tennessee, U. S. A. , on April 24-28, 1994. The symposium continued the interdisciplinary character and comprehensive approach of the preceding six symposia. Gaseous DielecIries VII is a detailed record of the symposium proceedings. It covers recent advances and developments in a wide range of basic, applied and industrial areas of gaseous dielectrics. It is hoped that Gaseous DielecIries VII will aid future research and development in, and encourage wider industrial use of, gaseous dielectrics. The Organizing Committee of the Seventh International Symposium on Gaseous Dielectrics consisted of G. Addis (U. S. A. ), L. G. Christophorou (U. S. A. ), F. Y. Chu (Canada), A. H. Cookson (U. S. A. ), O. Farish (U. K. ), I. Gallimberti (Italy) , A. Garscadden (U. S. A. ), D. R. James (U. S. A. ), E. Marode (France), T. Nitta (Japan), W. Pfeiffer (Germany), Y. Qiu (China), I. Sauers (U. S. A. ), R. J. Van Brunt (U. S. A. ), and W. Zaengl...

  17. The conditions of gaseous fuels development

    International Nuclear Information System (INIS)

    Anon.

    1996-01-01

    Face to the actual situation of petrol and gas oil in France, the situation of gaseous fuels appears to be rather modest. However, the aim of gaseous fuels is not to totally supersede the liquid fuels. Such a situation would imply a complete overturn which has not been seriously considered yet. This short paper describes the essential conditions to promote the wider use of gaseous fuels: the intervention of public authorities to adopt a more advantageous tax policy in agreement with the ''Clean Air''law project, a suitable distribution network for gaseous fuels, a choice of vehicles consistent with the urban demand, the development of transformation kits of quality and of dual-fuel vehicles by the car manufacturers. (J.S.)

  18. Position-sensitive gaseous photomultipliers research and applications

    CERN Document Server

    Francke, Tom; Peskov, Vladimir

    2016-01-01

    Gaseous photomultipliers are defined as gas-filled devices capable of recording single ultraviolet (UV) and visible photons with high position resolution. Used in a variety of research areas, these detectors can be paired with computers to treat and store imaging information of UV-light. Position-Sensitive Gaseous Photomultipliers: Research and Applications explores the advancement of gaseous detectors as applied for single photon detection. Emphasizing emerging perspectives and new ways to apply gaseous detectors across research fields, this research-based publication is an essential reference source for engineers, physicists, graduate-level students, and researchers.

  19. Treatment of Radioactive Gaseous Waste

    International Nuclear Information System (INIS)

    2014-07-01

    Radioactive waste, with widely varying characteristics, is generated from the operation and maintenance of nuclear power plants, nuclear fuel cycle facilities, research laboratories and medical facilities. The waste needs to be treated and conditioned as necessary to provide waste forms acceptable for safe storage and disposal. Although radioactive gaseous radioactive waste does not constitute the main waste flow stream at nuclear fuel cycle and radioactive waste processing facilities, it represents a major source for potential direct environmental impact. Effective control and management of gaseous waste in both normal and accidental conditions is therefore one of the main issues of nuclear fuel cycle and waste processing facility design and operation. One of the duties of an operator is to take measures to avoid or to optimize the generation and management of radioactive waste to minimize the overall environmental impact. This includes ensuring that gaseous and liquid radioactive releases to the environment are within authorized limits, and that doses to the public and the effects on the environment are reduced to levels that are as low as reasonably achievable. Responsibilities of the regulatory body include the removal of radioactive materials within authorized practices from any further regulatory control — known as clearance — and the control of discharges — releases of gaseous radioactive material that originate from regulated nuclear facilities during normal operation to the environment within authorized limits. These issues, and others, are addressed in IAEA Safety Standards Series Nos RS-G-1.7, WS-G-2.3 and NS-G-3.2. Special systems should be designed and constructed to ensure proper isolation of areas within nuclear facilities that contain gaseous radioactive substances. Such systems consist of two basic subsystems. The first subsystem is for the supply of clean air to the facility, and the second subsystem is for the collection, cleanup and

  20. Metodologias ativas para aprendizagem na educação superior: reflexões teóricas para a permanência

    OpenAIRE

    Dos Santos, Pricila Kohls; Spagnolo, Carla; Do Nascimento, Lorena Machado; Dos Santos, Bettina Steren

    2017-01-01

    O presente trabalho apresenta um estudo teórico sobre as metodologias ativas e a permanência na Educação superior. O principal objetivo é buscar subsídios teóricos que justifiquem a importância das metodologias ativas na Educação Superior e refletir sobre possibilidades de inovação curricular com implicações na permanência dos estudantes. As indagações motivadoras desta pesquisa baseiam-se nas seguintes questões: o que são as metodologias ativas? Qual a importância da utilização dessa metodol...

  1. Metodologia para estudo do volume e densidade absoluta da placenta humana de termo

    Directory of Open Access Journals (Sweden)

    Del Nero Ulisses

    2002-01-01

    Full Text Available OBJETIVO: comparar duas metodologias para o cálculo do volume placentário em gestações normais de termo: a do princípio de Arquimedes e a do volume do cilindro, para estimar a densidade absoluta da placenta. Definir a metodologia mais adequada para o cálculo do volume e densidade placentários, que se relacione com o peso e classificação do recém-nascido. MÉTODOS: foram estudadas 50 placentas provenientes de gestações de termo sem complicações e calculados o volume e a densidade absoluta placentários: a pelo princípio de Arquimedes e b na suposição de que a placenta seria uma secção de cilindro com duas alturas diferentes do bolo placentário: com a altura média e com a altura da média aritmética do centro e extremidades. As densidades absolutas placentárias foram calculadas pelo quociente entre o peso ao ar da placenta e os diferentes volumes. RESULTADOS: a maioria das gestantes eram multíparas, idade média de 25,4 anos, volume placentário médio entre 547,8 e 610 cmsuperscript three e densidade média entre 0,94 e 1,14 g/cmsuperscript three, dependendo da metodologia empregada. CONCLUSÕES: a metodologia mais adequada para estimar o volume placentário no termo foi a do princípio de Arquimedes, pela melhor correlação com o peso dos recém-nascidos, o índice placentário e a classificação do peso dos recém-nascidos em relação à idade gestacional.

  2. Dielectrophoretic separation of gaseous isotopes

    International Nuclear Information System (INIS)

    McConnell, D.B.

    1976-01-01

    This invention relates to a process for the separation of gaseous isotopes by electrophoresis assisted by convective countercurrent flow and to an apparatus for use in the process. The invention is especially applicable to heavy water separation from steam; however, it is to be understood that the invention is broadly applicable to the separation of gaseous isotopes having different dipole moments and/or different molecular weights. (author)

  3. Assessment of management alternatives for LWR wastes. Volume 5. Assessment of the radiological impact to the public resulting from discharges of radioactive effluents

    International Nuclear Information System (INIS)

    Centner, B.

    1993-01-01

    This report deals with the assessment of the radiological impact to the public resulting from discharges of radioactive effluents (liquid and gaseous) in connection with the implementation of the Belgian scenario for the management of PWR waste. Both individual and collective doses have been estimated for a critical group of the population living around the nuclear power plants concerned. This study is part of an overall theoretical exercise aimed at evaluating a selection of management wastes for LWR waste based on economical and radiological criteria

  4. CONCAWE effluent speciation project

    Energy Technology Data Exchange (ETDEWEB)

    Leonards, P.; Comber, M.; Forbes, S.; Whale, G.; Den Haan, K.

    2010-09-15

    In preparation for the implementation of the EU REACH regulation, a project was undertaken to transfer the high-resolution analytical method for determining hydrocarbon blocks in petroleum products by comprehensive two-dimensional gas chromatography (GCxGC) to a laboratory external to the petroleum industry (Institute for Environmental Studies (IVM) of the VU University of Amsterdam). The method was validated and used for the analysis of petroleum hydrocarbons extracted from refinery effluents. The report describes the technology transfer and the approaches used to demonstrate the successful transfer and application of the GCxGC methodology from analysing petroleum products to the quantitative determination of hydrocarbon blocks in refinery effluents. The report describes all the methods used for all the determinations on the effluent samples along with an overview of the results obtained which are presented in summary tables and graphs. These data have significantly improved CONCAWE's knowledge of what refineries emit in their effluents. A total of 111 Effluent Discharge Samples from 105 CONCAWE refineries in Europe were obtained in the period June 2008 to March 2009. These effluents were analysed for metals, standard effluent parameters (including COD, BOD), oil in water, BTEX and volatile organic compounds. The hydrocarbon speciation determinations and other hydrocarbon analyses are also reported. The individual refinery analytical results are included into this report, coded as per the CONCAWE system. These data will be, individually, communicated to companies and refineries. The report demonstrates that it is feasible to conduct a research programme to investigate the fate and effects of hydrocarbon blocks present in discharged refinery effluents.

  5. Hydrogen and Gaseous Fuel Safety and Toxicity

    Energy Technology Data Exchange (ETDEWEB)

    Lee C. Cadwallader; J. Sephen Herring

    2007-06-01

    Non-traditional motor fuels are receiving increased attention and use. This paper examines the safety of three alternative gaseous fuels plus gasoline and the advantages and disadvantages of each. The gaseous fuels are hydrogen, methane (natural gas), and propane. Qualitatively, the overall risks of the four fuels should be close. Gasoline is the most toxic. For small leaks, hydrogen has the highest ignition probability and the gaseous fuels have the highest risk of a burning jet or cloud.

  6. Method of separating tritium contained in gaseous wastes

    International Nuclear Information System (INIS)

    Hashimoto, Yasuo; Oozono, Hideaki.

    1981-01-01

    Purpose: To decrease tritium concentration in gaseous wastes to less than the allowable level by removing tritium in gaseous wastes generated upon combustion of radioactive wastes by using a plurality of heat exchangers. Method: Gaseous wastes at high temperature generated upon combustion of radioactive wastes in an incinerator are removed with radioactive solid substances through filters, cooled down to a temperature below 10 0 C by the passage through first and second heat exchangers and decreased with tritium content to less than the allowable concentration by the gaseous wastes at low temperature from the second heat exhcanger. The gaseous wastes at low temperature are used as the cooling medium for the first heat exchanger. They are heat exchanged at the upstream of the second heat exchanger with the cooling water from the third heat exchanger and cooled at the downstream by the cooling water cooled by the cooling medium. The gaseous wastes at low temperature thus cooled below 10 0 C are heated to about 350 0 C in the first heat exchanger and discharged. (Moriyama, K.)

  7. INEEL Liquid Effluent Inventory

    Energy Technology Data Exchange (ETDEWEB)

    Major, C.A.

    1997-06-01

    The INEEL contractors and their associated facilities are required to identify all liquid effluent discharges that may impact the environment at the INEEL. This liquid effluent information is then placed in the Liquid Effluent Inventory (LEI) database, which is maintained by the INEEL prime contractor. The purpose of the LEI is to identify and maintain a current listing of all liquid effluent discharge points and to identify which discharges are subject to federal, state, or local permitting or reporting requirements and DOE order requirements. Initial characterization, which represents most of the INEEL liquid effluents, has been performed, and additional characterization may be required in the future to meet regulations. LEI information is made available to persons responsible for or concerned with INEEL compliance with liquid effluent permitting or reporting requirements, such as the National Pollutant Discharge Elimination System, Wastewater Land Application, Storm Water Pollution Prevention, Spill Prevention Control and Countermeasures, and Industrial Wastewater Pretreatment. The State of Idaho Environmental Oversight and Monitoring Program also needs the information for tracking liquid effluent discharges at the INEEL. The information provides a baseline from which future liquid discharges can be identified, characterized, and regulated, if appropriate. The review covered new and removed buildings/structures, buildings/structures which most likely had new, relocated, or removed LEI discharge points, and at least 10% of the remaining discharge points.

  8. Liquid Effluent Retention Facility/Effluent Treatment Facility Hazards Assessment

    International Nuclear Information System (INIS)

    Simiele, G.A.

    1994-01-01

    This document establishes the technical basis in support of Emergency Planning activities for the Liquid Effluent Retention Facility and Effluent Treatment Facility the Hanford Site. The document represents an acceptable interpretation of the implementing guidance document for DOE ORDER 5500.3A. Through this document, the technical basis for the development of facility specific Emergency Action Levels and the Emergency Planning Zone is demonstrated

  9. Gaseous fuel reactors for power systems

    Science.gov (United States)

    Kendall, J. S.; Rodgers, R. J.

    1977-01-01

    Gaseous-fuel nuclear reactors have significant advantages as energy sources for closed-cycle power systems. The advantages arise from the removal of temperature limits associated with conventional reactor fuel elements, the wide variety of methods of extracting energy from fissioning gases, and inherent low fissile and fission product in-core inventory due to continuous fuel reprocessing. Example power cycles and their general performance characteristics are discussed. Efficiencies of gaseous fuel reactor systems are shown to be high with resulting minimal environmental effects. A technical overview of the NASA-funded research program in gaseous fuel reactors is described and results of recent tests of uranium hexafluoride (UF6)-fueled critical assemblies are presented.

  10. 40 CFR 426.113 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS GLASS MANUFACTURING POINT SOURCE CATEGORY Television Picture... applicable to the abrasive polishing and acid polishing waste water streams. Effluent characteristic Effluent...

  11. 40 CFR 427.43 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS ASBESTOS MANUFACTURING POINT SOURCE CATEGORY Asbestos Paper (Elastomeric Binder) Subcategory § 427.43 Effluent limitations guidelines representing the degree of effluent...

  12. 40 CFR 427.33 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS ASBESTOS MANUFACTURING POINT SOURCE CATEGORY Asbestos Paper (Starch Binder) Subcategory § 427.33 Effluent limitations guidelines representing the degree of effluent...

  13. 40 CFR 426.112 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS GLASS MANUFACTURING POINT SOURCE CATEGORY Television... stream): Effluent characteristic Effluent limitations Maximum for any 1 day Average of daily values for...

  14. Proposição de uma metodologia para análise de viabilidade econômica de uma usina fotovoltaica

    Directory of Open Access Journals (Sweden)

    Renata Guedes Almeida Ribeiro

    2017-06-01

    Full Text Available Uma metodologia para fins didáticos, de estudos de viabilidade econômica de uma usina solar fotovoltaica é proposta. O estudo foi realizado considerando o custo de operação e a instalação no período de 25 anos de uma usina de 3 MWp. A metodologia foi organizada em etapas, desde o estudo da irradiação solar na região, até o estudo de viabilidade econômica do investimento. A metodologia proposta foi validada por meio de um estudo de caso, no qual foram analisados três cenários de investimentos.

  15. TBP production plant effluent treatment process

    International Nuclear Information System (INIS)

    Sriniwas, C.; Sugilal, G.; Wattal, P.K.

    2004-06-01

    TBP production facility at Heavy Water Plant, Talcher generates about 2000 litres of effluent per 200 kg batch. The effluent is basically an aqueous solution containing dissolved and dispersed organics such as dibutyl phosphate, butanol etc. The effluent has high salinity, chemical oxygen demand (30-80 g/L) and pungent odour. It requires treatment before discharge. A chemical precipitation process using ferric chloride was developed for quantitative separation of organics from the aqueous part of the effluent. This process facilitates the discharge of the aqueous effluent. Results of the laboratory and bench scale experiments on actual effluent samples are presented in this report. (author)

  16. Kaizen: Uma Metodologia Inovadora na Siderurgia

    Directory of Open Access Journals (Sweden)

    Hericson Estanislau Prata

    2017-04-01

    Full Text Available A racionalização do processo produtivo industrial, por meio da redução dos desperdícios e da modernização do processo produtivo, com a adoção do Sistema Toyota de Produção (Produção Enxuta, tem sido adotada por uma parte importante das indústrias no mundo. O objetivo deste artigo é descrever essa metodologia empregada pelo grupo de melhoria de fase intensiva adotado na Vallourec Tubos do Brasil S.A. Como resultado, verificou-se que o processo utilizado para a implantação de mudanças em curto prazo foi a semana intensiva, também conhecida como evento Kaizen na indústria automotiva.

  17. Evaluation of leafy vegetables as bioindicators of gaseous mercury pollution in sewage-irrigated areas.

    Science.gov (United States)

    Zheng, Shun-An; Wu, Zeying; Chen, Chun; Liang, Junfeng; Huang, Hongkun; Zheng, Xiangqun

    2018-01-01

    Mercury (Hg) can evaporate and enter the plants through the stomata of plant leaves, which will cause a serious threat to local food safety and human health. For the risk assessment, this study aimed to investigate the concentration and accumulation of total gaseous mercury (TGM) in five typical leafy vegetables (Chinese chives (Allium tuberosum Rottler), amaranth (Amaranthus mangostanus L.), rape (Brassica campestris L.), lettuce (Lactuca sativa L.), and spinach (Spinacia oleracea L.)) grown on sewage-irrigated areas in Tianjin, China. The following three sites were chosen to biomonitor Hg pollution: a paddy field receiving sewage irrigation (industrial and urban sewage effluents) for the last 30 years, a vegetable field receiving sewage irrigation for 15 years, and a grass field which did not receive sewage irrigation in history. Results showed that the total Hg levels in the paddy (0.65 mg kg -1 ) and vegetation fields (0.42 mg kg -1 ) were significantly higher than the local background level (0.073 mg kg -1 ) and the China national soil environment quality standard for Hg in grade I (0.30 mg kg -1 ). The TGM levels in ambient air were significantly higher in the paddy (71.3 ng m -3 ) and vegetable fields (39.2 ng m -3 ) relative to the control (9.4 ng m -3 ) and previously reported levels (1.45 ng m -3 ), indicating severe Hg pollution in the atmospheric environment of the sewage-irrigated areas. Furthermore, gaseous mercury was the dominant form of Hg uptake in the leaves or irreversibly bound to leaves. The comparison of Hg uptake levels among the five vegetables showed that the gradient of Hg accumulation followed the order spinach > red amaranth > Chinese chives > rape > lettuce. These results suggest that gaseous Hg exposure in the sewage-irrigated areas is a dominant Hg uptake route in leafy vegetables and may pose a potential threat to agricultural food safety and human health.

  18. Gaseous phase heat capacity of benzoic acid

    NARCIS (Netherlands)

    Santos, L.M.N.B.F.; Alves da Rocha, M.A.; Gomes, L.R.; Schröder, B.; Coutinho, J.A.P.

    2010-01-01

    The gaseous phase heat capacity of benzoic acid (BA) was proven using the experimental technique called the "in vacuum sublimation/vaporization Calvet microcalorimetry drop method". To overcome known experimental shortfalls, the gaseous phase heat capacity of BA monomer was estimated by ab initio

  19. Gaseous diffusion -- the enrichment workhorse

    International Nuclear Information System (INIS)

    Shoemaker, J.E. Jr.

    1984-01-01

    Construction of the first large-scale gaseous diffusion facility was started as part of the Manhattan Project in Oak Ridge, Tennessee, in 1943. This facility, code named ''K-25,'' began operation in January 1945 and was fully on stream by September 1945. Four additional process buildings were later added in Oak Ridge as the demand for enriched uranium escalated. New gaseous diffusion plants were constructed at Paducah, Kentucky, and Portsmouth, Ohio, during this period. The three gaseous diffusion plants were the ''workhorses'' which provided the entire enriched uranium demand for the United States during the 1950s and 1960s. As the demand for enriched uranium for military purposes decreased during the early 1960s, power to the diffusion plants was curtailed to reduce production. During the 1960s, as plans for the nuclear power industry were formulated, the role of the diffusion plants gradually changed from providing highly-enriched uranium for the military to providing low-enriched uranium for power reactors

  20. UMA ANÁLISE DA IMPLEMENTAÇÃO DA METODOLOGIA LEAN STARTUP EM UMA EMPRESA DO RAMO DE ENTRETENIMENTO DIGITAL

    Directory of Open Access Journals (Sweden)

    João Pedro Boufleur

    2016-12-01

    Full Text Available A partir do final da década de 90, houve uma grande popularização do modelo de empresa conhecido como startup. As startups se diferenciaram por buscarem desenvolver produtos e serviços inovadores, mas contam com alto risco de falhar ao tentar atingir esse objetivo. Visto que os modelos tradicionais de administração não são considerados compatíveis com esse tipo de empresa, a metodologia Lean Startup propõe uma nova abordagem de trabalho para as startups alcançarem seu sucesso. Apesar de ser bastante difundida no meio empreendedor, esta metodologia é ainda pouco explorada academicamente. Portanto, o objetivo deste artigo é analisar a utilização do Lean Startup através de um estudo de caso no Superplayer, startup do ramo da tecnologia que usa a metodologia desde sua concepção. Como resultado do estudo foi possível descrever a utilização do Lean Startup e apontar vantagens e barreiras desta metodologia, gerando diretrizes que poderão auxiliar gestores e empreendedores que visam empregar a mesma em suas empresas.

  1. Waste Treatment Plant Liquid Effluent Treatability Evaluation

    International Nuclear Information System (INIS)

    LUECK, K.J.

    2001-01-01

    Bechtel National, Inc. (BNI) provided a forecast of the radioactive, dangerous liquid effluents expected to be generated by the Waste Treatment Plant (WTP). The forecast represents the liquid effluents generated from the processing of 25 distinct batches of tank waste through the WTP. The WTP liquid effluents will be stored, treated, and disposed of in the Liquid Effluent Retention Facility (LERF) and the Effluent Treatment Facility (ETF). Fluor Hanford, Inc. (FH) evaluated the treatability of the WTP liquid effluents in the LERFIETF. The evaluation was conducted by comparing the forecast to the LERFIETF treatability envelope, which provides information on the items that determine if a liquid effluent is acceptable for receipt and treatment at the LERFIETF. The WTP liquid effluent forecast is outside the current LERFlETF treatability envelope. There are several concerns that must be addressed before the WTP liquid effluents can be accepted at the LERFIETF

  2. 40 CFR 417.162 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Detergents Subcategory § 417.162 Effluent limitations guidelines... available (BPT): (a) For normal liquid detergent operations the following values pertain: Effluent...

  3. Metodologias de ensino para o desenvolvimento de competências do turismólogo: uma percepção do docente do curso de turismo da UFRN

    OpenAIRE

    Seixas, Eugênia Patrícia de Almeida

    2015-01-01

    As Metodologias de ensino podem ser definidas como elementos básicos de discussão da ação docente, no ato de ensinar e apresentar o conteúdo. Existem metodologias de ensino mais tradicionais com seus princípios mais voltados para decorar e o repetir, como também, metodologias ativas alicerçadas no principio da autonomia, e no desenvolvimento de competências. O objetivo do estudo é compreender a percepção dos docentes em relação à adoção das metodologias de ensino para o desenvolvimento de com...

  4. Decentralised wastewater treatment effluent fertigation: preliminary ...

    African Journals Online (AJOL)

    Decentralised wastewater treatment effluent fertigation: preliminary technical assessment. ... living in informal settlements with the effluent produced being used on agricultural land. ... Banana and taro required 3 514 mm of irrigation effluent.

  5. Process for exchanging hydrogen isotopes between gaseous hydrogen and water

    International Nuclear Information System (INIS)

    Hindin, S. G.; Roberts, G. W.

    1980-01-01

    A process for exchanging isotopes of hydrogen, particularly tritium, between gaseous hydrogen and water is provided whereby gaseous hydrogen depeleted in tritium and liquid or gaseous water containing tritium are reacted in the presence of a metallic catalyst

  6. Facility effluent monitoring plan for WESF

    Energy Technology Data Exchange (ETDEWEB)

    SIMMONS, F.M.

    1999-09-01

    The FEMP for the Waste Encapsulation and Storage Facility (WESF) provides sufficient information on the WESF effluent characteristics and the effluent monitoring systems so that a compliance assessment against applicable requirements may be performed. Radioactive and hazardous material source terms are related to specific effluent streams that are in turn, related to discharge points and, finally are compared to the effluent monitoring system capability.

  7. Silver precipitation from electrolytic effluents

    International Nuclear Information System (INIS)

    Rivera, I.; Patino, F.; Cruells, M.; Roca, A.; Vinals, J.

    2004-01-01

    The recovery of silver contained in electrolytic effluents is attractive due to its high economic value. These effluents are considered toxic wastes and it is not possible to dump them directly without any detoxification process. One of the most important way for silver recovery is the precipitation with sodium ditionite, sodium borohidride or hydrazine monohidrate. In this work, the most significant aspects related to the use of these reagents is presented. Results of silver precipitation with sodium ditionite from effluents containing thiosulfate without previous elimination of other species are also presented. silver concentration in the final effluents w <1 ppm. (Author) 15 refs

  8. Metodologia para determinação de corantes artificiais em alimentos por cromatografia liquida de alta eficiencia

    OpenAIRE

    Marcelo Alexandre Prado

    1998-01-01

    Resumo: O controle dos níveis de corantes artificiais utilizados em alimentos não é um procedimento rotineiro, especialmente, peia falta de metodologia adequada capaz de responder à demanda do número de análises e a determinações quantitativas nos mais variados tipos de alimentos, além de se tornar viável para implantação nos laboratórios de controle de nosso pais. Visando superar esse problema, foi desenvolvida e avaliada unia metodologia para a determinação qualitativa e quantitativa dos oi...

  9. Genotoxicity of swine effluents.

    Science.gov (United States)

    Techio, V H; Stolberg, J; Kunz, A; Zanin, E; Perdomo, C C

    2011-01-01

    This study aimed at the investigation of genotoxic effects of swine effluents from different stages of a treatment system for swine wastes through bioassay of stamen hairs and micronuclei in Tradescantia (clone BNL 4430). No significant differences (p≥0.05) regarding the genic mutations were found in the bioassay of stamen hairs, independently of the effluent analysed. For the genotoxicity test with micronuclei, the plants exposed to raw wastes, to sludge, and to effluent of the biodigester have presented higher rates of chromosomal damages (micronuclei), with significant differences in relation to the control group and other effluent of the waste treatment system (p≤0.05). The association between the chemical parameters and the genotoxicity data have shown that the variables COD and TKN have presented significant correlation (p≤0.05) with the number of mutagenic events in the tetrads.

  10. A metodologia de Lamarck

    Directory of Open Access Journals (Sweden)

    Lilian Al-Chueyr Pereira Martins

    1996-12-01

    Full Text Available Neste artigo, o método científico de Jean-Baptiste Lamarck é estudado sob o ponto de vista de seu discurso metodológico, bem como sob o ponto de vista de sua prática científica. Essa metodologia é comparada à preconizada por Condillac, assim como à dos "ideólogos" (idéologues grupo no qual se costuma incluir o próprio Lamarck. Mostra-se que o discurso metodológico de Lamarck assemelha-se ao dos ideólogos; no entanto, sua prática científica não se coaduna com esse enfoque. Em vez de seguir uma abordagem empirista, a obra de Lamarck se fundamenta em princípios metafísicos gerais sobre a natureza. Sob o ponto de vista dos ideólogos, seu trabalho deveria ser rejeitado - o que de fato ocorreu - como um mero sistema (système metafísico - no sentido pejorativo utilizado pelos seguidores de Condillac. No entanto, o presente artigo argumenta que esse é justamente um importante e inovador aspecto da obra de Lamarck, que permitiu a eclosão do evolucionismo moderno.

  11. A metodologia nos processos midiáticos

    OpenAIRE

    GOMES S. J, PEDRO GILBERTO

    2011-01-01

    Um grande desafio que temos hoje é a definiç ão e o estabelecimento do objeto da comunicaç ão. Este texto pretende discutir tanto a questão do objeto quando da metodologia nos processos mediáticos. Dizemos que o objeto precede ao método. Não podemos escolher um método se não se coñ éese o objeto. Para isso realiza um pequeno recorrido sobre o problema do método nas ciencias sociais e sua relaç ão com o objeto. A importância dessa discussão no âmbito da comunicaç ão está relacionada com o prob...

  12. Methods for reformation of gaseous hydrocarbons using electrical discharge

    KAUST Repository

    Cha, Min Suk

    2017-02-16

    Methods for the reformation of gaseous hydrocarbons are provided. The methods can include forming a bubble containing the gaseous hydrocarbon in a liquid. The bubble can be generated to pass in a gap between a pair of electrodes, whereby an electrical discharge is generated in the bubble at the gap between the electrodes. The electrodes can be a metal or metal alloy with a high melting point so they can sustain high voltages of up to about 200 kilovolts. The gaseous hydrocarbon can be combined with an additive gas such as molecular oxygen or carbon dioxide. The reformation of the gaseous hydrocarbon can produce mixtures containing one or more of H2, CO, H2O, CO2, and a lower hydrocarbon such as ethane or ethylene. The reformation of the gaseous hydrocarbon can produce low amounts of CO2 and H2O, e.g. about 15 mol-% or less.

  13. Methods for reformation of gaseous hydrocarbons using electrical discharge

    KAUST Repository

    Cha, Min; Zhang, Xuming

    2017-01-01

    Methods for the reformation of gaseous hydrocarbons are provided. The methods can include forming a bubble containing the gaseous hydrocarbon in a liquid. The bubble can be generated to pass in a gap between a pair of electrodes, whereby an electrical discharge is generated in the bubble at the gap between the electrodes. The electrodes can be a metal or metal alloy with a high melting point so they can sustain high voltages of up to about 200 kilovolts. The gaseous hydrocarbon can be combined with an additive gas such as molecular oxygen or carbon dioxide. The reformation of the gaseous hydrocarbon can produce mixtures containing one or more of H2, CO, H2O, CO2, and a lower hydrocarbon such as ethane or ethylene. The reformation of the gaseous hydrocarbon can produce low amounts of CO2 and H2O, e.g. about 15 mol-% or less.

  14. Ensenyar amb casos audiovisuals en l'entorn virtual: metodologia i resultats

    OpenAIRE

    Triadó i Ivern, Xavier Ma.; Aparicio Chueca, Ma. del Pilar (María del Pilar); Jaría Chacón, Natalia; Gallardo-Gallardo, Eva; Elasri Ejjaberi, Amal

    2010-01-01

    Aquest quadern pretén posar i donar a conèixer les bases d'una metodologia que serveixi per engegar experiències d'aprenentatge amb casos audiovisuals en l'entorn del campus virtual. Per aquest motiu, s'ha definit un protocol metodològic per utilitzar els casos audiovisuals dins l'entorn del campus virtual a diferents assignatures.

  15. Analysis of Process Gases and Trace Contaminants in Membrane-Aerated Gaseous Effluent Streams.

    Science.gov (United States)

    Coutts, Janelle L.; Lunn, Griffin Michael; Meyer, Caitlin E.

    2015-01-01

    In membrane-aerated biofilm reactors (MABRs), hollow fibers are used to supply oxygen to the biofilms and bulk fluid. A pressure and concentration gradient between the inner volume of the fibers and the reactor reservoir drives oxygen mass transport across the fibers toward the bulk solution, providing the fiber-adhered biofilm with oxygen. Conversely, bacterial metabolic gases from the bulk liquid, as well as from the biofilm, move opposite to the flow of oxygen, entering the hollow fiber and out of the reactor. Metabolic gases are excellent indicators of biofilm vitality, and can aid in microbial identification. Certain gases can be indicative of system perturbations and control anomalies, or potentially unwanted biological processes occurring within the reactor. In confined environments, such as those found during spaceflight, it is important to understand what compounds are being stripped from the reactor and potentially released into the crew cabin to determine the appropriateness or the requirement for additional mitigation factors. Reactor effluent gas analysis focused on samples provided from Kennedy Space Center's sub-scale MABRs, as well as Johnson Space Center's full-scale MABRs, using infrared spectroscopy and gas chromatography techniques. Process gases, such as carbon dioxide, oxygen, nitrogen, nitrogen dioxide, and nitrous oxide, were quantified to monitor reactor operations. Solid Phase Microextraction (SPME) GC-MS analysis was used to identify trace volatile compounds. Compounds of interest were subsequently quantified. Reactor supply air was examined to establish target compound baseline concentrations. Concentration levels were compared to average ISS concentration values and/or Spacecraft Maximum Allowable Concentration (SMAC) levels where appropriate. Based on a review of to-date results, current trace contaminant control systems (TCCS) currently on board the ISS should be able to handle the added load from bioreactor systems without the need

  16. Nuclear reactor effluent monitoring

    International Nuclear Information System (INIS)

    Minns, J.L.; Essig, T.H.

    1993-01-01

    Radiological environmental monitoring and effluent monitoring at nuclear power plants is important both for normal operations, as well as in the event of an accident. During normal operations, environmental monitoring verifies the effectiveness of in-plant measures for controlling the release of radioactive materials in the plant. Following an accident, it would be an additional mechanism for estimating doses to members of the general public. This paper identifies the U.S. Nuclear Regulatory Commission (NRC) regulatory basis for requiring radiological environmental and effluent monitoring, licensee conditions for effluent and environmental monitoring, NRC independent oversight activities, and NRC's program results

  17. Nuclear reactor effluent monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Minns, J.L.; Essig, T.H. [Nuclear Regulatory Commission, Washington, DC (United States)

    1993-12-31

    Radiological environmental monitoring and effluent monitoring at nuclear power plants is important both for normal operations, as well as in the event of an accident. During normal operations, environmental monitoring verifies the effectiveness of in-plant measures for controlling the release of radioactive materials in the plant. Following an accident, it would be an additional mechanism for estimating doses to members of the general public. This paper identifies the U.S. Nuclear Regulatory Commission (NRC) regulatory basis for requiring radiological environmental and effluent monitoring, licensee conditions for effluent and environmental monitoring, NRC independent oversight activities, and NRC`s program results.

  18. Effluent treatment for nuclear thermal propulsion ground testing

    Science.gov (United States)

    Shipers, Larry R.

    1993-01-01

    The objectives are to define treatment functions, review concept options, discuss PIPET effluent treatment system (ETS), and outline future activities. The topics covered include the following: reactor exhaust; effluent treatment functions; effluent treatment categories; effluent treatment options; concept evaluation; PIPETS ETS envelope; PIPET effluent treatment concept; and future activities.

  19. Handling and treatment of low-level radioactive wastes from gaseous diffusion plants in the United States of America

    International Nuclear Information System (INIS)

    Wing, J.F.; Behrend, J.E.

    1984-01-01

    Gaseous diffusion plants in the United States of America currently generate very small quantities of low-level radioactive wastes. These wastes consist primarily of airborne effluent solid trapping media and liquid scrubber solutions, liquid effluent treatment sludges, waste oils and solvents, scrap metals and conventional combustible wastes such as floor sweepings, cleaning rags and shoe covers. In addition to waste emanating from current operations, large quantities of scrap metal generated during the Cascade Improvement Program are stored above ground at each of the diffusion plants. The radionuclides of primary concern are uranium and 99 Tc. Current radioactive waste treatment consists of uranium dissolution in weak acids followed by chemical precipitation and/or solvent extraction for uranium recovery. Current disposal operations consist of above ground storage of scrap metals, shallow land burial of inorganic solids and incineration of combustible wastes. With increased emphasis on reducing the potential for off-site radiological dose, several new treatment and disposal options are being studied and new projects are being planned. One project of particular interest involves the installation of a high temperature incinerator to thermally degrade hazardous organic wastes contaminated with low-level radioactive wastes. Other technologies being studied include fixation of uranium-bearing sludges in concrete before burial, decontamination of scrap metals by smelting and use of specially engineered centralized burial grounds. (author)

  20. Absorbing method of iodine in radioactive gaseous wastes

    International Nuclear Information System (INIS)

    Fukutome, Yutaka; Mifuji, Hiroshi; Ito, Sakae.

    1983-01-01

    Purpose: To maintain an iodine adsorbing efficiency at a high level by keeping the adsorbing atmosphere to more than a predetermined temperature to thereby suppress the degradation and the activity reduction in zeolite. Method: Adsorption and desorption-regeneration of gaseous wastes are performed in parallel by heating gaseous wastes in a heater and switchingly supplying the same to adsorption columns by way of valve operation. Processed gases are cooled in a cooler and desorbed gases are supplied to an after-treatment device to eliminate or recover iodine 131. In the adsorption column, iodine in gaseous wastes is adsorbed to remove by using zeolite, wherein the adsorbing atmosphere is kept at a temperature higher than 40 0 C. This can prevent the formation of an aqueous HNO 3 solution from NO 2 and H 2 O contained in the gaseous wastes and prevent the degradation of the zeolite adsorption layer. (Kawakami, Y.)

  1. Supercritical water oxidation test bed effluent treatment study

    International Nuclear Information System (INIS)

    Barnes, C.M.

    1994-04-01

    This report presents effluent treatment options for a 50 h Supercritical Water Test Unit. Effluent compositions are calculated for eight simulated waste streams, using different assumed cases. Variations in effluent composition with different reactor designs and operating schemes are discussed. Requirements for final effluent compositions are briefly reviewed. A comparison is made of two general schemes. The first is one in which the effluent is cooled and effluent treatment is primarily done in the liquid phase. In the second scheme, most treatment is performed with the effluent in the gas phase. Several unit operations are also discussed, including neutralization, mercury removal, and evaporation

  2. Using broiler litter and swine manure lagoon effluent in sawdust-based swine mortality composts: Effects on nutrients, bacteria, and gaseous emissions

    International Nuclear Information System (INIS)

    McLaughlin, M.R.; Brooks, J.P.; Adeli, A.; Miles, D.M.

    2015-01-01

    Disposition of mortalities challenges confined animal feeding operations (CAFOs), especially sow (farrowing) farms, which experience mortalities daily. Regulations and transportation costs may preclude incineration, landfill burial, and rendering; therefore, swine CAFOs in Mississippi in the Mid-South U.S. often compost mortalities. In this study, a farm-standard composting mix of sawdust (S) and water (W) was compared with mixes where N was supplied by broiler litter (L) and water was replaced with swine lagoon effluent (E). The objective was to assess the effects of these manure byproducts: 1) on nutrients and bacteria in composts destined for land application; and 2) on emissions of ammonia and greenhouse gases. Three replications of four mixes (SW, SLW, SE, SLE) were compared in microcosms comprising modified plastic recycling bins. The experiment was repeated three times in different seasons in one year. Mixes were compared for differences in temperature, water content, nutrients (C, N, P, K, Ca, Mg, Na, Mn, Fe, Cu, Zn), bacteria (Gram −, Gram +, Clostridium perfringens, Salmonella, Listeria, Escherichia coli), and emissions (NH 3 , CO 2 , CH 4 , N 2 O). Litter addition increased composting temperatures initially and after aerations; increased nutrient concentrations, except C, in start mixes and all except C and N, in finish mixes; increased Gram + bacteria, Salmonella, and E. coli in start mixes, but only Gram+s in finish mixes; and increased emissions. Effluent addition increased early composting temperatures; had no effect on nutrients or bacteria, except increased C. perfringens in start, but not finish mixes; and had no effect on emissions. Nutrients in finish composts did not differ among mixes for N (average 3.3%), but litter composts had more P and K, and lower N:P than composts without litter. Improving mortality composting is of global importance as increasing livestock populations and intensive animal production systems require practical, safe

  3. Using broiler litter and swine manure lagoon effluent in sawdust-based swine mortality composts: Effects on nutrients, bacteria, and gaseous emissions

    Energy Technology Data Exchange (ETDEWEB)

    McLaughlin, M.R., E-mail: mike.mclaughlin@ars.usda.gov; Brooks, J.P.; Adeli, A.; Miles, D.M.

    2015-11-01

    Disposition of mortalities challenges confined animal feeding operations (CAFOs), especially sow (farrowing) farms, which experience mortalities daily. Regulations and transportation costs may preclude incineration, landfill burial, and rendering; therefore, swine CAFOs in Mississippi in the Mid-South U.S. often compost mortalities. In this study, a farm-standard composting mix of sawdust (S) and water (W) was compared with mixes where N was supplied by broiler litter (L) and water was replaced with swine lagoon effluent (E). The objective was to assess the effects of these manure byproducts: 1) on nutrients and bacteria in composts destined for land application; and 2) on emissions of ammonia and greenhouse gases. Three replications of four mixes (SW, SLW, SE, SLE) were compared in microcosms comprising modified plastic recycling bins. The experiment was repeated three times in different seasons in one year. Mixes were compared for differences in temperature, water content, nutrients (C, N, P, K, Ca, Mg, Na, Mn, Fe, Cu, Zn), bacteria (Gram −, Gram +, Clostridium perfringens, Salmonella, Listeria, Escherichia coli), and emissions (NH{sub 3}, CO{sub 2}, CH{sub 4}, N{sub 2}O). Litter addition increased composting temperatures initially and after aerations; increased nutrient concentrations, except C, in start mixes and all except C and N, in finish mixes; increased Gram + bacteria, Salmonella, and E. coli in start mixes, but only Gram+s in finish mixes; and increased emissions. Effluent addition increased early composting temperatures; had no effect on nutrients or bacteria, except increased C. perfringens in start, but not finish mixes; and had no effect on emissions. Nutrients in finish composts did not differ among mixes for N (average 3.3%), but litter composts had more P and K, and lower N:P than composts without litter. Improving mortality composting is of global importance as increasing livestock populations and intensive animal production systems require

  4. Gaseous Electronics Tables, Atoms, and Molecules

    CERN Document Server

    Raju, Gorur Govinda

    2011-01-01

    With the constant emergence of new research and application possibilities, gaseous electronics is more important than ever in disciplines including engineering (electrical, power, mechanical, electronics, and environmental), physics, and electronics. The first resource of its kind, Gaseous Electronics: Tables, Atoms, and Molecules fulfills the author's vision of a stand-alone reference to condense 100 years of research on electron-neutral collision data into one easily searchable volume. It presents most--if not all--of the properly classified experimental results that scientists, researchers,

  5. Precision tracking with a single gaseous pixel detector

    NARCIS (Netherlands)

    Tsigaridas, S.; van Bakel, N.; Bilevych, Y.; Gromov, V.; Hartjes, F.; Hessey, N.P.; de Jong, P.; Kluit, R.

    2015-01-01

    The importance of micro-pattern gaseous detectors has grown over the past few years after successful usage in a large number of applications in physics experiments and medicine. We develop gaseous pixel detectors using micromegas-based amplification structures on top of CMOS pixel readout chips.

  6. USERDA effluent data collection and reporting program

    International Nuclear Information System (INIS)

    Elle, D.R.; Schoen, A.A.

    1978-01-01

    Effluent and environmental monitoring has been conducted at United States Energy Research and Development Administration (formerly United States Atomic Energy Commission) facilities and sites virtually since the inception of atomic energy research and development. In 1971, computer systems were developed that permitted storage of information and data characterizing each effluent and onsite discharge point and relevant information on sources, effluent treatment and control systems, and discharge data, and serve as ERDA's computer-based management information systems for compiling waste discharge control and monitoring data on radioactivity released as airborne or liquid effluents or liquid discharges to onsite retention basins at ERDA facilities. The information systems and associated data outputs have proved to be an effective internal management tool for identifying effluent control problem areas and for surveying an agencywide Radioactive Effluent Reduction Program. The trend data facilitate the detection of gradual changes in the effectiveness of waste treatment systems, and errors or oversights in monitoring and data handling. Other computer outputs are useful for identifying effluent release points that have significantly higher or lower concentrations or quantities in the discharge stream than were measured the previous year. The year-to-year trend reports and the extensive computer edit and error checks have improved the reliability of the reported effluent data. Adoption of a uniform, centralized reporting system has improved the understanding and credibility of effluent data, and has allowed management to evaluate the effectiveness of effluent control practices at ERDA facilities. (author)

  7. Uma análise da implementação da metodologia lean startup em uma empresa do ramo de entretenimento digital

    Directory of Open Access Journals (Sweden)

    João Pedro Boufleur

    2016-12-01

    Full Text Available A partir do final da década de 90, houve uma grande popularização do modelo de empresa conhecido como startup. As startups se diferenciaram por buscarem desenvolver produtos e serviços inovadores, mas contam com alto risco de falhar ao tentar atingir esse objetivo. Visto que os modelos tradicionais de administração não são considerados compatíveis com esse tipo de empresa, a metodologia Lean Startup propõe uma nova abordagem de trabalho para as startups alcançarem seu sucesso. Apesar de ser bastante difundida no meio empreendedor, esta metodologia é ainda pouco explorada academicamente. Portanto, o objetivo deste artigo é analisar a utilização do Lean Startup através de um estudo de caso no Superplayer, startup do ramo da tecnologia que usa a metodologia desde sua concepção. Como resultado do estudo foi possível descrever a utilização do Lean Startup e apontar vantagens e barreiras desta metodologia, gerando diretrizes que poderão auxiliar gestores e empreendedores que visam empregar a mesma em suas empresas.

  8. Statistical evaluation of effluent monitoring data for the 200 Area Treated Effluent Disposal Facility

    International Nuclear Information System (INIS)

    Chou, C.J.; Johnson, V.G.

    2000-01-01

    The 200 Area Treated Effluent Disposal Facility (TEDF) consists of a pair of infiltration basins that receive wastewater originating from the 200 West and 200 East Areas of the Hanford Site. TEDF has been in operation since 1995 and is regulated by State Waste Discharge Permit ST 4502 (Ecology 1995) under the authority of Chapter 90.48 Revised Code of Washington (RCW) and Washington Administrative Code (WAC) Chapter 173-216. The permit stipulates monitoring requirements for effluent (or end-of-pipe) discharges and groundwater monitoring for TEDF. Groundwater monitoring began in 1992 prior to TEDF construction. Routine effluent monitoring in accordance with the permit requirements began in late April 1995 when the facility began operations. The State Waste Discharge Permit ST 4502 included a special permit condition (S.6). This condition specified a statistical study of the variability of permitted constituents in the effluent from TEDF during its first year of operation. The study was designed to (1) demonstrate compliance with the waste discharge permit; (2) determine the variability of all constituents in the effluent that have enforcement limits, early warning values, and monitoring requirements (WHC 1995); and (3) determine if concentrations of permitted constituents vary with season. Additional and more frequent sampling was conducted for the effluent variability study. Statistical evaluation results were provided in Chou and Johnson (1996). Parts of the original first year sampling and analysis plan (WHC 1995) were continued with routine monitoring required up to the present time

  9. Entrapment process of radioactive gaseous wastes

    International Nuclear Information System (INIS)

    Gagneraud, Francis; Gagneraud, Michel.

    1981-01-01

    Process for collecting chemically inert gaseous radioactive waste in melted substances, whereby the gaseous waste is injected under pressure in a molten substance to its saturation point followed by fast cooling. This substance is constituted of glass, ceramics, metallurgical drosses and slag masses in fusion. Its cooling is carried out by quenching by means of running water or a gas fluid, or by casting into vessels with great thermal inertia such as cast iron or similar, before recovery and confinement in receptacles for storage [fr

  10. Thermal discharges from Paducah Gaseous Diffusion Plant outfalls: Impacts on stream temperatures and fauna of Little Bayou and Big Bayou Creeks

    International Nuclear Information System (INIS)

    Roy, W.K.; Ryon, M.G.; Hinzman, R.L.

    1996-03-01

    The development of a biological monitoring plan for the receiving streams of the Paducah Gaseous Diffusion Plant (PGDP) began in the late 1980s, because of an Agreed Order (AO) issued in September 1987 by the Kentucky Division of Water (KDOW). Five years later, in September 1992, more stringent effluent limitations were imposed upon the PGDP operations when the KDOW reissued Kentucky Pollutant Discharge Elimination System permit No. KY 0004049. This action prompted the US Department of Energy (DOE) to request a stay of certain limits contained in the permit. An AO is being negotiated between KDOW, the US Enrichment Corporation (USEC), and DOE that will require that several studies be conducted, including this stream temperature evaluation study, in an effort to establish permit limitations. All issues associated with this AO have been resolved, and the AO is currently being signed by all parties involved. The proposed effluent temperature limit is 89 F (31.7 C) as a mean monthly temperature. In the interim, temperatures are not to exceed 95 F (35 C) as a monthly mean or 100 F (37.8 C) as a daily maximum. This study includes detailed monitoring of instream temperatures, benthic macroinvertebrate communities, fish communities, and a laboratory study of thermal tolerances

  11. Thermal discharges from Paducah Gaseous Diffusion Plant outfalls: Impacts on stream temperatures and fauna of Little Bayou and Big Bayou Creeks

    Energy Technology Data Exchange (ETDEWEB)

    Roy, W.K.; Ryon, M.G.; Hinzman, R.L. [Oak Ridge National Lab., TN (United States). Computer Science and Mathematics Div.

    1996-03-01

    The development of a biological monitoring plan for the receiving streams of the Paducah Gaseous Diffusion Plant (PGDP) began in the late 1980s, because of an Agreed Order (AO) issued in September 1987 by the Kentucky Division of Water (KDOW). Five years later, in September 1992, more stringent effluent limitations were imposed upon the PGDP operations when the KDOW reissued Kentucky Pollutant Discharge Elimination System permit No. KY 0004049. This action prompted the US Department of Energy (DOE) to request a stay of certain limits contained in the permit. An AO is being negotiated between KDOW, the US Enrichment Corporation (USEC), and DOE that will require that several studies be conducted, including this stream temperature evaluation study, in an effort to establish permit limitations. All issues associated with this AO have been resolved, and the AO is currently being signed by all parties involved. The proposed effluent temperature limit is 89 F (31.7 C) as a mean monthly temperature. In the interim, temperatures are not to exceed 95 F (35 C) as a monthly mean or 100 F (37.8 C) as a daily maximum. This study includes detailed monitoring of instream temperatures, benthic macroinvertebrate communities, fish communities, and a laboratory study of thermal tolerances.

  12. Thermal Discharges from Paducah Gaseous Diffusion Plant Outfalls: Impacts on Stream Temperatures and Fauna of Little Bayou and Big Bayou Creeks

    International Nuclear Information System (INIS)

    Roy, W.K.

    1999-01-01

    The development of a biological monitoring plan for the receiving streams of the Paducah Gaseous Diffusion Plant (PGDP) began in the late 1980s, because of an Agreed Order (AO) issued in September 1987 by the Kentucky Division of Water (KDOW). Five years later, in September 1992, more stringent effluent limitations were imposed upon the PGDP operations when the KDOW reissued Kentucky Pollutant Discharge Elimination System permit No. KY 0004049. This action prompted the US Department of Energy (DOE) to request a stay of certain limits contained in the permit. An AO is being negotiated between KDOW, the United States Enrichment Corporation (USEC), and DOE that will require that several studies be conducted, including this stream temperature evaluation study, in an effort to establish permit limitations. All issues associated with this AO have been resolved, and the AO is currently being signed by all parties involved. The proposed effluent temperature limit is 89 F (31.7C) as a mean monthly temperature. In the interim, temperatures are not to exceed 95 F (35 C) as a monthly mean or 100 F (37.8 C) as a daily maximum. This study includes detailed monitoring of instream temperatures, benthic macroinvertebrate communities, fish communities, and a laboratory study of thermal tolerances

  13. Thermal Discharges from Paducah Gaseous Diffusion Plant Outfalls: Impacts on Stream Temperatures and Fauna of Little Bayou and Big Bayou Creeks

    Energy Technology Data Exchange (ETDEWEB)

    Roy, W.K.

    1999-01-01

    The development of a biological monitoring plan for the receiving streams of the Paducah Gaseous Diffusion Plant (PGDP) began in the late 1980s, because of an Agreed Order (AO) issued in September 1987 by the Kentucky Division of Water (KDOW). Five years later, in September 1992, more stringent effluent limitations were imposed upon the PGDP operations when the KDOW reissued Kentucky Pollutant Discharge Elimination System permit No. KY 0004049. This action prompted the US Department of Energy (DOE) to request a stay of certain limits contained in the permit. An AO is being negotiated between KDOW, the United States Enrichment Corporation (USEC), and DOE that will require that several studies be conducted, including this stream temperature evaluation study, in an effort to establish permit limitations. All issues associated with this AO have been resolved, and the AO is currently being signed by all parties involved. The proposed effluent temperature limit is 89 F (31.7C) as a mean monthly temperature. In the interim, temperatures are not to exceed 95 F (35 C) as a monthly mean or 100 F (37.8 C) as a daily maximum. This study includes detailed monitoring of instream temperatures, benthic macroinvertebrate communities, fish communities, and a laboratory study of thermal tolerances.

  14. Percepção discente sobre metodologias de ensino na graduação do curso de Ciências do Estado da UFMG (2009-2013

    Directory of Open Access Journals (Sweden)

    Thelma Yanagisawa Shimomura

    2016-07-01

    Full Text Available RESUMO: O Curso de Ciências do Estado resultou da adesão da Faculdade de Direito da Universidade Federal de Minas Gerais ao Programa de Apoio ao Plano de Reestruturação e Expansão das Universidades Federais (REUNI. Criado em 2009, tem como objetivo a formação de profi ssionais com conhecimento amplo do funcionamento da estrutura estatal como também capacidade para liderar e planejar políticas públicas com visão humanística. Em seu Projeto Pedagógico de Curso adotou o seminário como metodologia de ensino/aprendizagem, com a fi nalidade de estimular o diálogo crítico e a produção do conhecimento de forma cooperativa entre estudantes e professores. O presente trabalho analisou a preferência dos discentes sobre a utilização de várias metodologias de ensino/aprendizagem no curso de Ciências de Estado. Foi realizada pesquisa bibliográfi ca e participante, além da aplicação de questionário aos discentes. Na análise das respostas do questionário foi possível perceber que na visão dos alunos entrevistados, especifi camente quanto a metodologia de seminário, esta não foi a metodologia mais apreciada, por muitas vezes não ser aplicada como metodologia de ensino, e sim como método avaliativo. Mesm o assim, esta metodologia foi considerada importante para desenvolver as habilidades necessárias para a formação do cientista do estado. PALAVRAS-CHAVE: Ciências do Estado; Seminário de Capacitação; Metodologias de ensino/aprendizagem; Ensino Superior.

  15. Flow proportional sampling of low level liquid effluent

    International Nuclear Information System (INIS)

    Colley, D.; Jenkins, R.

    1989-01-01

    A flow proportional sampler for use on low level radioactive liquid effluent has been developed for installation on all CEGB nuclear power stations. The sampler, operates by drawing effluent continuously from the main effluent pipeline, through a sampler loop and returning it to the pipeline. The effluent in this loop is sampled by taking small, frequent aliquots using a linear acting shuttle valve. The frequency of operation of this valve is controlled by a flowmeter installed in the effluent line; sampling rate being directly proportional to effluent flowrate. (author)

  16. Metodologia design thinking no projeto de software para mobilidade urbana: relato de aplicação

    Directory of Open Access Journals (Sweden)

    Adailton Magalhaes Lima

    2015-03-01

    Full Text Available Introdução: Apresenta um relato da condução de um estudo onde se aplicou a metodologia Design Thinking no contexto do projeto de uma solução de software ao contexto de mobilidade urbana. Método: Dentre as técnicas sugeridas pela metodologia Design Thinking, este trabalho utilizou entrevistas, surveys, brainstorming e prototipação. O foco do estudo foram os transportes públicos e os processos intrínsecos a esse contexto. Resultados: Tem-se um projeto de solução aderente aos problemas identificados nas pesquisas de campo, e também uma avaliação conduzida com os usuários alvo sobre o projeto de solução proposto. Conclusão: A aplicação de Design Thinking pode ser eficiente no desenvolvimento de software, pois se tem nessa metodologia um direcionamento na elaboração de projetos centrada na construção de produtos voltados para atender as necessidades de seus usuários, ou seja, projeta-se a solução com base no quão usual o produto será para o usuário final.

  17. Novas metodologias na didática da Economia e Contabilidade – caso do Mestrado em Ensino português

    Directory of Open Access Journals (Sweden)

    Ana Luísa Rodrigues

    2017-12-01

    Full Text Available Este estudo objetivou analisar o desenvolvimento de novas metodologias, designadamente a aplicação da Formação Ativa, no ensino de disciplinas do Mestrado em Ensino de Economia e de Contabilidade português, tendo em linha de conta as percepções dos futuros professores sobre o que é (ou deverá ser Professor(a de Economia e de Contabilidade. A metodologia de investigação utilizada foi a de estudo de caso, com observação participante, numa abordagem predominantemente qualitativa, suportada na investigação da própria prática, procurando caminhos para a inovação dos processos educativos em face do novo paradigma tecnológico contemporâneo. Foi constatada a aplicabilidade da Formação Ativa e obtidos resultados que verificaram a sua eficácia no ensino da Economia e Contabilidade, com o desenvolvimento de metodologias de aprendizagem ativas, que se pretende que contribuam para o desenvolvimento pessoal e profissional docente na futura sociedade do conhecimento.

  18. O USO DE METODOLOGIAS ALTERNATIVAS NO ENSINO DE BIBLIOTECONOMIA: GAMIFICAÇÃO COMO ESTRATÉGIA PEDAGÓGICA

    Directory of Open Access Journals (Sweden)

    Denise Braga Sampaio

    2017-02-01

    Full Text Available Aborda o uso da gamificação nas turmas de ‘Introdução à Biblioteconomia’, ‘Linguagens Documentárias Alfanuméricas: CDD’ e ‘Produção Textual’, em 2017 e ‘Representação Temática da Informação: indexação’, em 2016 como metodologia alternativa ao processo de ensino-aprendizagem. Tem como objetivo evidenciar o uso da gamificação no ensino de Biblioteconomia na UFCA e contribuir para a reflexão sobre a prática docente e o uso de metodologias alternativas no ensino superior. Traz como questão central a assimilação do conhecimento e a missão docente no novo milênio. Através de uma pesquisa descritiva, procura evidenciar a referida prática e os benefícios observados no processo avaliativo. Os resultados mostram que, majoritariamente, os alunos se identificaram com as aulas gamificadas, bem como apresentaram maior aproveitamento destas, ao passo que tem interesse de ver tal metodologia utilizada em outras disciplinas.

  19. Portsmouth Gaseous Diffusion Plant expansion: final environmental statement. Volume 2. Appendices

    International Nuclear Information System (INIS)

    1977-09-01

    Volume 2 is comprised of appendices: Portsmouth Gaseous Diffusion Plant Existing Facilities; Ecology; Civic Involvement; Social Analysis; Population Projections; Toxicity of Air Pollutants to Biota at Portsmouth Gaseous Diffusion Plant; and Assessment of Noise Effects of an Add-On to the Portsmouth Gaseous Diffusion Plant

  20. Microbial production of gaseous hydrocarbons

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, Hideo

    1987-10-20

    Microbial production of ethylene, isobutane and a saturated gaseous hydrocarbon mixture was described. Microbial ethylene production was studied with Penicillium digitatum IFO 9372 and a novel pathway of the ethylene biosynthesis through alpha-ketoglutarate was proposed. Rhodotorula minuta IFO 1102 was selected for the microbial production of isobutane and the interesting actions of L-leucine and L-phenylalanine for the isobutane production were found. It was finally presented about the microbial production of a saturated gaseous hydrocarbon mixture with Rhizopus japonicus IFO 4758 was described. A gas mixture was produced through a chemical reaction of SH compounds and some cellular component such as squalene under aerobic conditions. (4 figs, 7 tabs, 41 refs)

  1. Gaseous emissions from coal stockpiles

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-01-15

    Stockpiled coal undergoes atmospheric oxidation and desorption processes during open air storage. These processes release gases to the environment which may effect health and safety by their toxicity and flammability. In extreme cases, this could lead to a fire. This report discusses gaseous emissions from coal stockpiles. It covers gas emission mechanisms, and gas sampling and testing methods, before examining in more detail the principal gases that have been emitted. It concludes that there is limited research in this area and more data are needed to evaluate the risks of gaseous emissions. Some methods used to prevent coal self-heating and spontaneous combustion can be applied to reduce emissions from coal stockpiles.

  2. 40 CFR 417.82 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Soaps Subcategory § 417.82 Effluent limitations guidelines representing the...

  3. 40 CFR 415.342 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... SOURCE CATEGORY Chrome Pigments Production Subcategory § 415.342 Effluent limitations guidelines... available (BPT): Subpart AH—Chrome Pigments Pollutant or pollutant property BPT effluent limitations Maximum...

  4. 40 CFR 407.67 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS CANNED AND PRESERVED FRUITS AND VEGETABLES PROCESSING POINT SOURCE CATEGORY Canned and Preserved Fruits Subcategory § 407.67 Effluent limitations guidelines...

  5. 40 CFR 407.77 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS CANNED AND PRESERVED FRUITS AND VEGETABLES PROCESSING POINT SOURCE CATEGORY Canned and Preserved Vegetables Subcategory § 407.77 Effluent limitations guidelines...

  6. 40 CFR 406.73 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... economically achievable. 406.73 Section 406.73 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY....73 Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

  7. Animal alternatives for whole effluent toxicity testing ...

    Science.gov (United States)

    Since the 1940s, effluent toxicity testing has been utilized to varying degrees in many countries to assess potential ecological impacts and assist in determining necessary treatment options for environmental protection. However, it was only in the early 1980’s that toxicity based effluent assessments and subsequent discharge controls became globally important, when it was recognized that physical and chemical measurements alone did not protect the environment from potential impacts. Consequently, various strategies using different toxicity tests, whole effluent assessment techniques (incorporating bioaccumulation potential and persistence) plus supporting analytical tools have been developed over 30 years of practice. Numerous workshops and meetings have focused on effluent risk assessment through ASTM, SETAC, OSPAR, UK competent authorities, and EU specific country rules. Concurrent with this drive to improve effluent quality using toxicity tests, interest in reducing animal use has risen. The Health and Environmental Sciences Institute (HESI) organized and facilitated an international workshop in March 2016 to evaluate strategies for concepts, tools, and effluent assessments and update the toolbox of for effluent testing methods. The workshop objectives were to identify opportunities to use a suite of strategies for effluents, and to identify opportunities to reduce the reliance on animal tests and to determine barriers to implementation of new methodologie

  8. Liquid effluent processing group. Activity details 1963

    International Nuclear Information System (INIS)

    1964-08-01

    This report first gives a quantitative overview of volumes of effluents of high activity, medium activity and low activity which passed through the department for effluent processing. It also makes the distinction between the shape or type of container of these effluents. A table indicates their origin and another indicates their destination. The β and α decontamination rates are determined, and the assessment of stored aqueous and organic effluents on the 31 December 1963 is given. The next part proposes an assessment of laboratory activities: control operations (input controls, control of processed effluent before discarding), controls related to processing (processing types, radiochemical and chemical dosing performed on effluent mixes before processing). Tables indicate the characteristics of medium activity effluents collected in 1963, the results of high activity liquid analysis, and Beryllium dosing results. A summary of ALEA processing, a table of the characteristics of stored oils and solvents are given. The third part reports data related to transport activities, and various works performed in the Saclay plant to improve exploitation conditions and results

  9. Tecnologia e Metodologia no Ensino de Inglês: Impactos da Globalização e da Internacionalização

    Directory of Open Access Journals (Sweden)

    Kyria Rebeca Finardi

    2014-07-01

    Full Text Available http://dx.doi.org/10.5007/2175-8026.2014n66p239 O artigo reflete sobre o papel das tecnologias nas diversas metodologias de ensino de inglês e sobre o impacto da globalização e internacionalização na educação em geral e no ensino de inglês em especial. O estudo é baseado no pressuposto de que o acesso à informação e à tecnologia é necessário para a construção de capital social (WARSCHAUER, 2003 e que esse acesso exige algum conhecimento de inglês e letramento digital (FINARDI; PREBIANCA; MOMM, 2013. Partimos de uma revisão bibliográfica sobre o uso de metodologias no ensino de inglês e do papel das tecnologias nessas metodologias para propor que tanto a resistência a quanto o uso acrítico de tecnologias pode ter consequências negativas tanto para o desenvolvimento da proficiência em inglês quanto para o desenvolvimento social do Brasil. O estudo conclui que na era do pós método (BROWN, 2002; KUMARAVADIVELO, 2003 e da informação (LEVY, 1999 as tecnologias têm um papel relevante e crucial que deve ser considerado criticamente nas metodologias de ensino de línguas. O estudo sugere ainda que o uso informado de tecnologias e metodologias, aliado ao ensino de inglês como língua internacional são essenciais para alavancar o desenvolvimento e a internacionalização da educação no Brasil de forma crítica em relação aos efeitos da globalização.

  10. 40 CFR 417.83 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Soaps Subcategory § 417.83 Effluent limitations guidelines representing the degree of...

  11. 40 CFR 415.647 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... CATEGORY Cadmium Pigments and Salts Production Subcategory § 415.647 Effluent limitations guidelines... subject to this subpart and producing cadmium pigments must achieve the following effluent limitations...

  12. 40 CFR 415.643 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... CATEGORY Cadmium Pigments and Salts Production Subcategory § 415.643 Effluent limitations guidelines... subject to this subpart and producing cadmium pigments must achieve the following effluent limitations...

  13. 40 CFR 406.32 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... technology currently available. 406.32 Section 406.32 Protection of Environment ENVIRONMENTAL PROTECTION... Milling Subcategory § 406.32 Effluent limitations guidelines representing the degree of effluent reduction...

  14. 40 CFR 406.42 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... technology currently available. 406.42 Section 406.42 Protection of Environment ENVIRONMENTAL PROTECTION... Milling Subcategory § 406.42 Effluent limitations guidelines representing the degree of effluent reduction...

  15. 40 CFR 406.52 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... technology currently available. 406.52 Section 406.52 Protection of Environment ENVIRONMENTAL PROTECTION... Milling Subcategory § 406.52 Effluent limitations guidelines representing the degree of effluent reduction...

  16. 40 CFR 406.12 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... technology currently available. 406.12 Section 406.12 Protection of Environment ENVIRONMENTAL PROTECTION... Subcategory § 406.12 Effluent limitations guidelines representing the degree of effluent reduction attainable...

  17. 40 CFR 406.33 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... economically achievable. 406.33 Section 406.33 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Subcategory § 406.33 Effluent limitations guidelines representing the degree of effluent reduction attainable...

  18. 40 CFR 406.53 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... economically achievable. 406.53 Section 406.53 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Subcategory § 406.53 Effluent limitations guidelines representing the degree of effluent reduction attainable...

  19. 40 CFR 424.73 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... economically achievable. 424.73 Section 424.73 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Chromium Subcategory § 424.73 Effluent limitations guidelines representing the degree of effluent reduction...

  20. PERCEPÇÕES SOBRE ENSINO DE METODOLOGIA DA PESQUISA NO MESTRADO

    Directory of Open Access Journals (Sweden)

    Pelayo Munhoz Olea

    2011-12-01

    Full Text Available Este estudo investiga a alteração no método de ensino da disciplina de Metodologia da Pesquisa da primeira para a segunda turma do Mestrado em Administração da Universidade de Caxias do Sul (UCS. A pesquisa se baseou em um estudo exploratório, sendo realizadas entrevistas semidirigidas com o professor da disciplina, com cinco alunos da primeira turma (22% do total e cinco da segunda turma (também 22%. As entrevistas revelaram vantagens/desvantagens de cada método, resultados de aprendizagem e percepções sobre a importância da disciplina. Através da comparação entre os dois momentos da disciplina, concluiu-se que houve evolução no método de ensino e descreveram-se estratégias consideradas facilitadoras para a aprendizagem. Percebeu-se ainda que é fundamental refletir sobre as formas de ensinar Metodologia da Pesquisa e valorizar a interação em sala de aula, devido à importância da disciplina para a atuação do aluno-pesquisador na seqüência do curso e em uma possível carreira acadêmica.

  1. Waste analysis plan for the 200 area effluent treatment facility and liquid effluent retention facility

    International Nuclear Information System (INIS)

    Ballantyne, N.A.

    1995-01-01

    This waste analysis plan (WAP) has been prepared for startup of the 200 Area Effluent Treatment Facility (ETF) and operation of the Liquid Effluent Retention Facility (LERF), which are located on the Hanford Facility, Richland, Washington. This WAP documents the methods used to obtain and analyze representative samples of dangerous waste managed in these units, and of the nondangerous treated effluent that is discharged to the State-Approved Land Disposal System (SALDS). Groundwater Monitoring at the SALDS will be addressed in a separate plan

  2. 40 CFR 440.23 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Science.gov (United States)

    2010-07-01

    ...) EFFLUENT GUIDELINES AND STANDARDS ORE MINING AND DRESSING POINT SOURCE CATEGORY Aluminum Ore Subcategory... discharged in mine drainage from mines producing bauxite ores shall not exceed: Effluent characteristic...

  3. 40 CFR 440.22 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS ORE MINING AND DRESSING POINT SOURCE CATEGORY Aluminum Ore... pollutants discharged in mine drainage from mines producing bauxite ores shall not exceed: Effluent...

  4. 40 CFR 414.73 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Science.gov (United States)

    2010-07-01

    ... achievable (BAT). 414.73 Section 414.73 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... § 414.73 Effluent limitations representing the degree of effluent reduction attainable by the...

  5. 40 CFR 410.73 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Science.gov (United States)

    2010-07-01

    ... achievable (BAT). 410.73 Section 410.73 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... § 410.73 Effluent limitations representing the degree of effluent reduction attainable by the...

  6. Engineering design of the Aries-IV gaseous divertor

    International Nuclear Information System (INIS)

    Hasan, M.Z.; Najmabadi, F.; Sharafat, S.

    1994-01-01

    ARIES-IV is a conceptual, D-T burning, steady-state tokamak fusion reactor producing 1000 MWe net. It operates in the second plasma stability regime. The structural material is SiC composite and the primary coolant is helium at 10MPa base pressure. ARIES-IV uses double-null divertors for particle control. Total thermal power recovered from the divertors is 425MW, which is 16% of the total reactor thermal power. Among the desirable goals of divertor design were to avoid the use of tungsten and to use the same structural material and primary coolant as in the blanket design. In order to reduce peak heat flux, the innovative gaseous divertor has been used in ARIES-IV. A gaseous divertor reduces peak heat flux by increasing the surface area and by distributing particle and radiation energy more uniformly. Another benefit of gaseous divertor is the reduction of plasma temperature in the divertor chamber, so that material erosion due to sputtering, can be diminished. This makes the use of low-Z material possible in a gaseous divertor

  7. Growth of graphene films from non-gaseous carbon sources

    Science.gov (United States)

    Tour, James; Sun, Zhengzong; Yan, Zheng; Ruan, Gedeng; Peng, Zhiwei

    2015-08-04

    In various embodiments, the present disclosure provides methods of forming graphene films by: (1) depositing a non-gaseous carbon source onto a catalyst surface; (2) exposing the non-gaseous carbon source to at least one gas with a flow rate; and (3) initiating the conversion of the non-gaseous carbon source to the graphene film, where the thickness of the graphene film is controllable by the gas flow rate. Additional embodiments of the present disclosure pertain to graphene films made in accordance with the methods of the present disclosure.

  8. Gaseous isotope correlation technique for safeguards at reprocessing facilities

    International Nuclear Information System (INIS)

    Ohkubo, Michiaki.

    1988-03-01

    The isotope correlation technique based on gaseous stable fission products can be used as a means of verifying the input measurement to fuel reprocessing plants. This paper reviews the theoretical background of the gaseous fission product isotope correlation technique. The correlations considered are those between burnup and various isotopic ratios of Kr and Xe nuclides. The feasibility of gaseous ICT application to Pu input accountancy of reprocessing facilities is also discussed. The technique offers the possibility of in situ measurement verification by the inspector. (author). 16 refs, 7 figs

  9. Flux and polarization signals of spatially inhomogeneous gaseous exoplanets

    NARCIS (Netherlands)

    Karalidi, T.; Stam, D.M.; Guirado, D.

    2013-01-01

    Aims. We present numerically calculated, disk-integrated, spectropolarimetric signals of starlight that is reflected by vertically and horizontally inhomogeneous gaseous exoplanets. We include various spatial features that are present on Solar System’s gaseous planets: belts and zones, cyclonic

  10. Radiation treatment of sewage effluent, (2)

    International Nuclear Information System (INIS)

    Sawai, Teruko; Sekiguchi, Masayuki; Sawai, Takeshi; Shimokawa, Toshinari; Tanabe, Hiroko

    1991-01-01

    The water demand of the past several years has increased rapidly. Recycling of municipal waste water is an effective mean of coping with the water shortage in Tokyo. We studied the radiation treatment method of further purification of the effluent from sewage treatment plants. By gamma irradiation the refractory organic substances in the effluent were decomposed and the COD values decreased with increasing dose. The high molecular weight components in the effluent were degraded to lower molecular weight substances and were decomposed finally to carbon dioxide. In this paper we studied on the fading color and the reducing of order of sewage effluent. (author)

  11. Facility effluent monitoring plan for WESF

    International Nuclear Information System (INIS)

    SIMMONS, F.M.

    1999-01-01

    The FEMP for the Waste Encapsulation and Storage Facility (WESF) provides sufficient information on the WESF effluent characteristics and the efferent monitoring systems so that a compliance assessment against applicable requirements may be performed. Radioactive and hazardous material source terms are related to specific effluent streams that are in turn, related to discharge points and, finally are compared to the effluent monitoring system capability

  12. Filtration device for active effluents

    International Nuclear Information System (INIS)

    Guerin, M.; Meunier, G.

    1994-01-01

    Among the various techniques relating to solid/liquid separations, filtration is currently utilized for treating radioactive effluents. After testing different equipments on various simulated effluents, the Valduc Center has decided to substitute a monoplate filter for a rotative diatomite precoated filter

  13. 40 CFR 420.73 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Science.gov (United States)

    2010-07-01

    ... achievable (BAT). 420.73 Section 420.73 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Subcategory § 420.73 Effluent limitations representing the degree of effluent reduction attainable by the...

  14. Characterisation of potential aquaculture pond effluents, and ...

    African Journals Online (AJOL)

    Conventional treatment of effluents from these small-scale, low-volume operations, which discharge relatively dilute effluents infrequently, might not be cost-effective. Keywords: aquaculture–environment interaction, earthen ponds, effluent characterisation, K-means clustering, t ilapia, water quality. African Journal of Aquatic ...

  15. The effluent problem in a plutonium production centre; Probleme des effluents d'un centre de production de plutonium

    Energy Technology Data Exchange (ETDEWEB)

    Galley, R; Cantel, J [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    The first part of the report is devoted to generalities: the geographical situation of the Marcoule Centre, the sources of radio-active effluent, methods of treating this effluent. In the second part the authors gives a detailed description of the various installations in the Radio-active Effluent Treatment Station at the Marcoule Centre, and outline the conditions governing the rejection of treated effluent into the Rhone. A few lines are given to comparisons between the results obtained from the use of these installations up till may 1959 and the expected results published by the same authors at the Brussels Conference (1956). In conclusion the authors lay down some of the essential principles, applicable to the study of new installations. (author) [French] La premiere partie du rapport est consacree a quelques generalites: situation geographique du Centre de Marcoule, provenance des effluents radioactifs, methodes de traitement de ces effluents. Dans la seconde partie, les auteurs presentent une description detaillee des diverses installations de la Station de Traitement des Effluents radioactifs du Centre de Marcoule et precisent les conditions de rejet dans le Rhone des effluents radioactifs traites. Quelques lignes sont consacrees aux comparaisons entre les resultats de l'exploitation des installations jusqu'en mai 1959 et les previsions publiees par les memes auteurs a l'occasion de la Conference de Bruxelles (1956). En conclusion, les auteurs donnent quelques principes essentiels, applicables a l'etude de nouvelles installations. (auteur)

  16. Ecological and biomedical effects of effluents from near-term electric vehicle storage battery cycles

    Energy Technology Data Exchange (ETDEWEB)

    1980-05-01

    An assessment of the ecological and biomedical effects due to commercialization of storage batteries for electric and hybrid vehicles is given. It deals only with the near-term batteries, namely Pb/acid, Ni/Zn, and Ni/Fe, but the complete battery cycle is considered, i.e., mining and milling of raw materials, manufacture of the batteries, cases and covers; use of the batteries in electric vehicles, including the charge-discharge cycles; recycling of spent batteries; and disposal of nonrecyclable components. The gaseous, liquid, and solid emissions from various phases of the battery cycle are identified. The effluent dispersal in the environment is modeled and ecological effects are assessed in terms of biogeochemical cycles. The metabolic and toxic responses by humans and laboratory animals to constituents of the effluents are discussed. Pertinent environmental and health regulations related to the battery industry are summarized and regulatory implications for large-scale storage battery commercialization are discussed. Each of the seven sections were abstracted and indexed individually for EDB/ERA. Additional information is presented in the seven appendixes entitled; growth rate scenario for lead/acid battery development; changes in battery composition during discharge; dispersion of stack and fugitive emissions from battery-related operations; methodology for estimating population exposure to total suspended particulates and SO/sub 2/ resulting from central power station emissions for the daily battery charging demand of 10,000 electric vehicles; determination of As air emissions from Zn smelting; health effects: research related to EV battery technologies. (JGB)

  17. Metodologia de ensino e aprendizagem sobre relacionamento interpessoal no ambiente de trabalho

    Directory of Open Access Journals (Sweden)

    Claudia Simone Cordeiro Pelissoli

    2017-02-01

    Full Text Available O trabalho busca uma metodologia de ensino-aprendizagem para o conteúdo “relacionamento interpessoal” na disciplina Gestão de Pessoas, buscando qualificar os alunos para a carreira profissional. Justifica-se sua importância devido à problemática de que muitos profissionais apresentam dificuldades em atender e cativar as pessoas no ambiente de trabalho, com o intuito de viabilizar uma postura mais adequada que o torne diferenciado. O objetivo do trabalho é aplicar uma metodologia em sala de aula que provoque a reflexão dos alunos quanto ao seu relacionamento interpessoal, sendo que é um tema subjetivo e saber lidar com as pessoas é essencial no sucesso profissional. Trata-se de um estudo de caso aplicado no IFRS – campus Osório com alunos do Curso Superior de Tecnologia em Processos Gerenciais. Um dos resultados aponta para a importância de se estudar meios de melhorar o processo de ensino e aprendizagem para uma melhor reflexão na vida profissional e pessoal, mesclando diferentes métodos de ensino, aliando a teoria com a realidade de forma dinâmica, provocando um posicionamento crítico do aluno.

  18. Methanization of industrial liquid effluents; Methanisation des effluents industriels liquides

    Energy Technology Data Exchange (ETDEWEB)

    Frederic, S.; Lugardon, A. [Societe Naskeo Environnement, 92 - Levallois-Perret (France)

    2007-09-15

    In a first part, this work deals with the theoretical aspects of the methanization of the industrial effluents; the associated reactional processes are detailed. The second part presents the technological criteria for choosing the methanization process in terms of the characteristics of the effluent to be treated. Some of the methanization processes are presented with their respective advantages and disadvantages. At last, is described the implementation of an industrial methanization unit. The size and the main choices are detailed: the anaerobic reactor, the control, the valorization aspects of the biogas produced. Some examples of industrial developments illustrate the different used options. (O.M.)

  19. Uranium enrichment by the gaseous diffusion process

    International Nuclear Information System (INIS)

    Petit, J.F.

    1977-01-01

    After a brief description of the process and technology (principle, stage constitution, cascade constitution, and description of a plant), the author gives the history of gaseous diffusion and describes the existing facilities. Among the different enrichment processes contemplated in the USA during and after the last world war, gaseous diffusion has been the only one to be developed industrially on a wide scale in the USA, then in the UK, in the USSR and in France. The large existing capacities in the USA provided the country with a good starting base for the development of a light-water nuclear power plant programme, the success of which led to a shortfall in production means. France and the USA, possessing the necessary know-how, have been able to undertake the realization of two industrial programmes: the CIP-CUP programme in the USA and the Eurodif project in France. Current plans still call for the construction of several plants by 1990. Can the gaseous diffusion process meet this challenge. Technically, there is no doubt about it. Economically, this process is mainly characterized by large energy consumption and the necessity to build large plants. This leads to a large investment, at least for the first plant. Other processes have been developed with a view to reducing both energy and capital needs. However, in spite of continuous studies and technological progress, no process has yet proved competitive. Large increments in capacities are still expected to come from gaseous diffusion, and several projects taking into account the improvements in flexibility, automatization, reliability and reduced investment, are analysed in the paper. Combining new facilities with existing plants has already proved to be of great interest. This situation explains why gaseous diffusion is being further investigated and new processes are being studied. (author)

  20. Metodologia para avaliação de impacto ambiental de macrófitas em mesocosmos Methodology for assessing the environmental impact of macrophytes on mesocosms

    Directory of Open Access Journals (Sweden)

    G.L. Guimarães

    2003-01-01

    Full Text Available Este trabalho teve como objetivo analisar a metodologia para avaliação do impacto ambiental causado pelo uso de herbicidas no controle de macrófitas. O desenho e a construção dos mesocosmos são descritos em detalhes, como também a forma como foram inseridos lâminas para coleta e medida da comunidade perifítica e sedimento para avaliação da comunidade bentônica. O método utilizado foi o de fluxo contínuo, e vários parâmetros de qualidade de água foram medidos, além da determinação de resíduos na coluna d'água e no sedimento. A intenção de se utilizar um método de fluxo contínuo foi buscar uma situação mais próxima da realidade, a fim de que os resultados obtidos possam espelhar com maior exatidão os possíveis riscos provenientes do uso de substâncias químicas no controle das macrófitas. Alguns ajustes devem ser feitos nessa metodologia para melhor caracterização dos efluentes e calibração do sistema.This experiment aimed to analyze the methodology applied to evaluate the environmental impact caused by the use of herbicide to control macrophytes. The design and construction of the tanks are described in detail as well as the insertion of blades for periphyton and sediment sampling to evaluate the bentonic comunities. The flow-through method was used and several parameters of water quality were measured and residues detected in the water colunm and sediment. The flow-through methodology was chosen to create a situation closer to reality so that the results obtained could more precisely reflect the likely risks caused by chemical control of macrophytes. Some adjustments need to be made in this methodology for a better characterization of the effluents and calibration of the system.

  1. Hanford Facility dangerous waste permit application, liquid effluent retention facility and 200 area effluent treatment facility

    International Nuclear Information System (INIS)

    Coenenberg, J.G.

    1997-01-01

    The Hanford Facility Dangerous Waste Permit Application is considered to 10 be a single application organized into a General Information Portion (document 11 number DOE/RL-91-28) and a Unit-Specific Portion. The scope of the 12 Unit-Specific Portion is limited to Part B permit application documentation 13 submitted for individual, 'operating' treatment, storage, and/or disposal 14 units, such as the Liquid Effluent Retention Facility and 200 Area Effluent 15 Treatment Facility (this document, DOE/RL-97-03). 16 17 Both the General Information and Unit-Specific portions of the Hanford 18 Facility Dangerous Waste Permit Application address the content of the Part B 19 permit application guidance prepared by the Washington State Department of 20 Ecology (Ecology 1987 and 1996) and the U.S. Environmental Protection Agency 21 (40 Code of Federal Regulations 270), with additional information needs 22 defined by the Hazardous and Solid Waste Amendments and revisions of 23 Washington Administrative Code 173-303. For ease of reference, the Washington 24 State Department of Ecology alpha-numeric section identifiers from the permit 25 application guidance documentation (Ecology 1996) follow, in brackets, the 26 chapter headings and subheadings. A checklist indicating where information is 27 contained in the Liquid Effluent Retention Facility and 200 Area Effluent 28 Treatment Facility permit application documentation, in relation to the 29 Washington State Department of Ecology guidance, is located in the Contents 30 Section. 31 32 Documentation contained in the General Information Portion is broader in 33 nature and could be used by multiple treatment, storage, and/or disposal units 34 (e.g., the glossary provided in the General Information Portion). Wherever 35 appropriate, the Liquid Effluent Retention Facility and 200 Area Effluent 36 Treatment Facility permit application documentation makes cross-reference to 37 the General Information Portion, rather than duplicating

  2. Hanford Facility dangerous waste permit application, liquid effluent retention facility and 200 area effluent treatment facility

    Energy Technology Data Exchange (ETDEWEB)

    Coenenberg, J.G.

    1997-08-15

    The Hanford Facility Dangerous Waste Permit Application is considered to 10 be a single application organized into a General Information Portion (document 11 number DOE/RL-91-28) and a Unit-Specific Portion. The scope of the 12 Unit-Specific Portion is limited to Part B permit application documentation 13 submitted for individual, `operating` treatment, storage, and/or disposal 14 units, such as the Liquid Effluent Retention Facility and 200 Area Effluent 15 Treatment Facility (this document, DOE/RL-97-03). 16 17 Both the General Information and Unit-Specific portions of the Hanford 18 Facility Dangerous Waste Permit Application address the content of the Part B 19 permit application guidance prepared by the Washington State Department of 20 Ecology (Ecology 1987 and 1996) and the U.S. Environmental Protection Agency 21 (40 Code of Federal Regulations 270), with additional information needs 22 defined by the Hazardous and Solid Waste Amendments and revisions of 23 Washington Administrative Code 173-303. For ease of reference, the Washington 24 State Department of Ecology alpha-numeric section identifiers from the permit 25 application guidance documentation (Ecology 1996) follow, in brackets, the 26 chapter headings and subheadings. A checklist indicating where information is 27 contained in the Liquid Effluent Retention Facility and 200 Area Effluent 28 Treatment Facility permit application documentation, in relation to the 29 Washington State Department of Ecology guidance, is located in the Contents 30 Section. 31 32 Documentation contained in the General Information Portion is broader in 33 nature and could be used by multiple treatment, storage, and/or disposal units 34 (e.g., the glossary provided in the General Information Portion). Wherever 35 appropriate, the Liquid Effluent Retention Facility and 200 Area Effluent 36 Treatment Facility permit application documentation makes cross-reference to 37 the General Information Portion, rather than duplicating

  3. The treatment of effluents

    International Nuclear Information System (INIS)

    Wormser, G.; Rodier, J.; Robien, E. de; Fernandez, N.

    1964-01-01

    For several years the French Atomic Energy Commission has been studying with interest problems presented by radio-active effluents. Since high activities have not yet received a definite solution we will deal only, in this paper, with the achievements and research concerning low and medium activity effluents. In the field of the achievements, we may mention the various effluent treatment stations which have been built in France; a brief list will be given together with an outline of their main new features. Thus in particular the latest treatment stations put into operation (Grenoble, Fontenay-aux-Roses, Cadarache) will be presented. From all these recent achievements three subjects will be dealt with in more detail. 1 - The workshop for treating with bitumen the sludge obtained after concentration of radionuclides. 2 - The workshop for treating radioactive solid waste by incineration. 3 - A unit for concentrating radio-active liquid effluents by evaporation. In the field of research, several topics have been undertaken, a list will be given. In most cases the research concerns the concentration of radionuclides with a view to a practical and low cost storage, a concentration involving an efficient decontamination of the aqueous liquids in the best possible economic conditions. For improving the treatments leading to the concentration of nuclides, our research has naturally been concerned with perfecting the treatments used in France: coprecipitation and evaporation. In our work we have taken into account in particular two conditions laid down in the French Centres. 1 - A very strict sorting out of the effluents at their source in order to limit in each category the volume of liquid to be dealt with. 2 - The necessity for a very complete decontamination due to the high population density in our country. In the last past we present two original methods for treating liquid effluents. 1 - The use of ion-exchange resins for liquids containing relatively many salts. The

  4. Generation of gaseous tritium standards

    International Nuclear Information System (INIS)

    Hohorst, F.A.

    1994-09-01

    The determination of aqueous and non-aqueous tritium in gaseous samples is one type of determination often requested of radioanalytical laboratories. This determination can be made by introducing the sample as a gas into a sampling train containing two silica gel beds separated by.a catalytic oxidizer bed. The first bed traps tritiated water. The sample then passes into and through the oxidizer bed where non-aqueous tritium containing species are oxidized to water and other products of combustion. The second silica gel bed then traps the newly formed tritiated water. Subsequently, silica gel is removed to plastic bottles, deionized water is added, and the mixture is permitted to equilibrate. The tritium content of the equilibrium mixture is then determined by conventional liquid scintillation counting (LSC). For many years, the moisture content of inert, gaseous samples has been determined using monitors which quantitatively electrolyze the moisture present after that moisture has been absorbed by phosphorous pentoxide or other absorbents. The electrochemical reaction is quantitative and definitive, and the energy consumed during electrolysis forms the basis of the continuous display of the moisture present. This report discusses the experimental evaluation of such a monitor as the basis for a technique for conversion of small quantities of SRMs of tritiated water ( 3 HOH) into gaseous tritium standards ( 3 HH)

  5. Análise da Metodologia Criada por Miguel Cifuentes Referente à Capacidade de Carga Turística

    Directory of Open Access Journals (Sweden)

    Maurício Delgado

    2013-02-01

    Full Text Available Muitos pesquisadores do setor turístico têm utilizado a metodologia da capacidade de carga. A idéia básica é estabelecer um número máximo de visitantes em uma determinada localidade, com o objetivo de minimizar os impactos provocados pela visitação. Entretanto, esta metodologia está incompleta ao atrelar os impactos da visitação apenas ao número de visitantes, deixando de considerar aspectos subjetivos e qualitativos relacionados ao turismo. Esta pesquisa demonstra a falta de cientificidade desta metodologia e salienta que limitar o número de visitantes é apenas um dos métodos de controle dos impactos provocados pelo turismo. Many researchers in the tourism sector have used the methodology of carrying capacity. The basic principie is to establish a maximum number of visitors in some place in order to minimize the impact of tourism. However, this methodology is incomplete as it only relates the impacts of tourist activity to the number of visitors, without considering some of the subjective and qualitative aspects of the effects of tourism. This research demonstrates the unscientific nature of this methodology and stresses that limiting the number of visitors to a locality is only one method to control the impacts of tourism.

  6. Inteligência Competitiva: metodologias aplicadas em empresas brasileiras
    Inteligencia Competitiva: metodologías aplicadas en las empresas brasileñas

    OpenAIRE

    Mônica Erichsen Nassif; Frederico Vidigal

    2012-01-01

    Introdução: Apresenta um panorama acerca da Inteligência Competitiva no contexto das organizações brasileiras. Objetivo: Investiga a existência de metodologias de Inteligência Competitiva aplicadas a organizações nacionais e multinacionais de diferentes segmentos de mercado. Metodologia: Revisão de literatura nacional e internacional – envolvendo o status quo da atividade de Inteligência Competitiva no mundo – e cujo conteúdo foi confrontado com os resultados obtidos em entrevistas realiza...

  7. ANÁLISE DA METODOLOGIA DE COLETA DE DADOS ESTATÍSTICOS DE VISITAÇÃO NO PARQUE NACIONAL DO IGUAÇU – CASO PASSE COMUNIDADE

    Directory of Open Access Journals (Sweden)

    Ana Cristina Rempel de Olivera

    2016-04-01

    Full Text Available O artigo teve como objetivo analisar a metodologia utilizada para coletar dados estatísticos de visitação da comunidade em um atrativo natural, o estudo foi desenvolvido através de cinco etapas, que consistiram em revisão teórica e documental, obtenção da autorização necessária para a coleta de dados, elaboração do instrumento de coleta de dados, seleção da amostra, e a análise dos dados. O procedimento realizado no Parque Nacional do Iguaçu foi selecionado como amostra, posteriormente o mesmo foi analisado de acordo com a revisão bibliográfica acerca da importância da realização de pesquisas, e as metodologias e variáveis aplicadas ao turismo, que foram comparadas ao método utilizado no atrativo, concluindo que parte das metodologias e variáveis utilizadas em turismo pode ser aplicável aos atrativos turísticos. Palavras-chave: Metodologia; Estatística; Atrativo Natural; Comunidade.

  8. Nutrient removal from swine lagoon effluent by duckweed

    Energy Technology Data Exchange (ETDEWEB)

    Bergmann, B.A.; Cheng, J.; Classen, J.; Stomp, A.M.

    2000-04-01

    Three duckweed geographic isolates were grown on varying concentrations of swine lagoon effluent in a greenhouse to determine their ability to remove nutrients from the effluent. Duckweed biomass was harvested every other day over a 12-day period. Duckweed biomass production, nutrient loss from the swine lagoon effluent, and nutrient content of duckweed biomass were used to identify effluent concentrations/geographic isolate combinations that are effective in terms of nutrient utilization from swine lagoon effluent and production of healthy duckweed biomass. When Lemna minor geographic isolate 8627 was grown on 50% swine lagoon effluent, respective losses of TKN, NH{sub 3}-N, TP, OPO{sub 4}-P, TOC, K, Cu, and Zn were 83, 100, 49, 31, 68, 21, 28 and 67%.

  9. PFOS and PFOA in influents, effluents, and biosolids of Chinese wastewater treatment plants and effluent-receiving marine environments

    International Nuclear Information System (INIS)

    Chen Hong; Zhang Can; Han Jianbo; Yu Yixuan; Zhang Peng

    2012-01-01

    Concentrations of perfluorooctane sulfonate (PFOS) and perfluorooctanoate (PFOA) in influents, effluents and sludges were investigated by analyzing the samples from twelve wastewater treatment plants (WWTPs) in China. The highest concentrations of PFOS and PFOA in influents were found to occur in municipal and industrial WWTPs, respectively. Relative to PFOS and PFOA concentrations in influents, elevated concentrations were observed in effluents from WWTPs applying anaerobic–anoxic–oxic wastewater treatment process. Importantly, application of previously reported organic carbon normalized partition coefficients (K OC ) derived from sediment-based sorption experiments appear to underestimate the PFOS and PFOA levels in biosolids quantified in the current study. PFOS and PFOA levels in effluents were found to be approximately 27 and 2 times higher than those detected in the effluent-receiving seawater, respectively. However, their levels in this area of seawater haven't exceeded the provisional short-term health advisories in drinking water issued by U.S. EPA yet. - Highlights: ► Levels of PFOS and PFOA in influents, effluents and sludge from Chinese WWTPs were examined. ► Municipal sewage was the main source for PFOS in Chinese WWTPs, while industrial sewage for PFOA. ► PFOS and PFOA concentrations in effluents were much higher than those in receiving seawater. - Levels of PFOS and PFOA in influent, effluent and sludge samples from Chinese WWTPs were examined and found much higher than those in receiving seawater.

  10. Liquid and gaseous wastes from pressurised water reactors: International comparison

    International Nuclear Information System (INIS)

    Benedittini, M.

    1989-04-01

    This report presents the main results of a comparison on radioactive effluents releases from ninety-four PWRs in the following countries: Belgium, Federal Republic of Germany, France, Japan, Sweden, Switzerland and the United States. For liquid releases, distinctions have been undertaken between tritium and no tritium activities and for gaseous releases between noble gases and halogens-aerosols. Data have been collected from literature published or by contacting utilities responsible or authorities in order to constitute a data bank. However for the comparison, reactors for which commercial operation starts before July 1974, have been excluded. As far as the main comparative results are concerned, the averages of tritium activity per energy production unit for liquid releases are ranging between 1840 GBq/TWh and 3000 GBq/TWh and two groups of countries may be noted: those for which the results are around 2000 GBq/TWh as Frg, Japan and Switzerland and those which have an activity level around 3000 GBq/TWh as Belgium, France and Sweden. The United States are between these two groups. A factor which may provide an explanation for these discrepancies concerns practices for primary circuit: recycling it, leads to a lower tritium activity for releases and to a higher tritium activity concentration in the primary circuit. Excluding tritium, mean liquid activities per reactor are widely varying from one country to another: - lower than 0,05 GBq in Japan and in Switzerland; - from one thousand to two thousand times higher in France, Sweden and the United States. Discrepancies for gaseous activities are narrower: a factor of 40 in noble gases activities and a factor of 25 for halogens and aerosols activities. In conclusion, for activities of the tritium liquid as well as activities of all other types of radionuclides, countries can be shared in two groups according the activity level - For the lowest: FRG, Japan and Switzerland; - For the highest: Belgium, France and Sweden

  11. Liquid and gaseous wastes from pressurised water reactors: international comparison

    International Nuclear Information System (INIS)

    Benedittini, M.

    1989-04-01

    This report presents the main results of a comparison on radioactive effluents releases from ninety-four PWRs in the following countries: Belgium, Federal Republic of Germany, France, Japan, Sweden, Switzerland and the United States. For liquid releases, distinctions have been undertaken between tritium and no tritium activities and for gaseous releases between noble gases and halogens-aerosols. Data have been collected from literature published or by contacting utilities responsible or authorities in order to constitute a data bank. However for the comparison, reactors for which commercial operation starts before July 1974, have been excluded. As far as the main comparative results are concerned, the averages of tritium activity per energy production unit for liquid releases are ranging between 1840 GBq/TWh and 3000 GBq/TWh and two groups of countries may be noted: those for which the results are around 2000 GBq/TWh as FRG, Japan and Switzerland and those which have an activity level around 3000 GBq/TWh as Belgium, France and Sweden. The United States are between these two groups. A factor which may provide an explanation for these discrepancies concerns practices for primary circuit: recycling it, leads to a lower tritium activity for releases and to a higher tritium activity concentration in the primary circuit. Excluding tritium, mean liquid activities per reactor are widely varying from one country to another: - lower than 0,05 GBq in Japan and in Switzerland; - from one thousand to two thousand times higher in France, Sweden and the United States. Discrepancies for gaseous activities are narrower: a factor of 40 in noble gases activities and a factor of 25 for halogens and aerosols activities. In conclusion, for activities of the tritium liquid as well as activities of all other types of radionuclides, countries can be shared in two groups according the activity level - For the lowest: FRG, Japan and Switzerland; - For the highest: Belgium, France and Sweden

  12. Metodologias ativas de ensino e aprendizagem: uma experiência com docentes da educação básica

    OpenAIRE

    Antônio Eustáquio Ferreira

    2017-01-01

    Relato com o objetivo de descrever a experiência de um curso de formação continuada de professores, cujo título é Metodologias Ativas de Ensino e Aprendizagem: uma experiência com docentes da educação básica, desenvolvido em parceria com a Universidade Federal da Grande Dourados, sob a coordenação e execução do autor. Os resultados evidenciaram que o contato dos docentes da educação básica com algumas técnicas das Metodologias Ativas de Ensino e Aprendizagem provocam reflexões sobre suas atit...

  13. Effluent Guidelines

    Science.gov (United States)

    Effluent guidelines are national standards for wastewater discharges to surface waters and municipal sewage treatment plants. We issue the regulations for industrial categories based on the performance of treatment and control technologies.

  14. Cytogenotoxicity evaluation of two industrial effluents using Allium ...

    African Journals Online (AJOL)

    ISHIOMA

    textile effluent was 4.5 times more toxic than the paint effluent. ... Key words: Genotoxicity, paint, textile, industrial effluents, Allium cepa, mutation, pollution, chromosomal .... concentration of a chemical producing 50% of the total effect).

  15. UMA METODOLOGIA VOLTADA PARA O DESENVOLVIMENTO DE LÍDERES

    OpenAIRE

    Carvalho, Leila de Moura

    2003-01-01

    Este trabalho aborda uma metodologia voltada para o desenvolvimento do grupo de líderes da Divisão Logística de uma empresa do setor de varejo. Em uma pesquisa realizada pela empresa, detectou-se uma deficiência no estilo de supervisão atual adotada pelo grupo de líderes e as conseqüências negativas geradas para a organização. A proposta deste trabalho é promover a educação e o treinamento do grupo de líderes para uma mudança de estilo de supervisão. Para isso, propõe-se a utilizar como base ...

  16. modelling effluent assimila modelling effluent assimilat modelling

    African Journals Online (AJOL)

    eobe

    G EFFLUENT ASSIMILATIVE CAPACITY OF IKPOBA RIVE. BENIN CITY, NIGERIA ... l purposes to communities rse such as ... treat in order for it to meet the aforeme of the communities. It is therefore i ..... Substituting and integrating yields the following equations ..... Purification Potentials of Small Tropical Urban. Stream: A ...

  17. Public doses estimation based on effluents data and direct measurements of Tritium in environmental samples at Cernavoda

    International Nuclear Information System (INIS)

    Bobric, E.; Popescu, I.; Simionov, V.

    2002-01-01

    The release of any potential radioactive pollutant to the environment during routine operation of a Nuclear Power Plant should be the subject of appropriate controls and assessments. The layout of the Candu reactor and the design of its systems ensure that the radioactive waste quantities are minimized, but small amounts of radioisotopes are continuously discharged at very low concentrations through gaseous and liquid effluents. Radioprotection of the public is based on the principles recommended by ICRP, the protection being mainly achieved by control of the sources of exposure. Source monitoring provide a means of assessing the radiation exposure of population groups, critical groups and individual members of the public. The assessed doses are used to demonstrate the compliance with authorized dose limits - 1 mSv / year in our case - but can also be used for optimization purposes

  18. Gaseous waste processing device in nuclear power plant

    International Nuclear Information System (INIS)

    Takechi, Eisuke; Matsutoshi, Makoto.

    1978-01-01

    Purpose: To arrange the units of waste processing devices in a number one more than the number thereof required for a plurality of reactors, and to make it usable commonly as a preliminary waste processing device thereby to effectively use all the gaseous waste processing devices. Constitution: A gaseous waste processing device is constituted by an exhaust gas extractor, a first processing device, a second processing device and the like, which are all connected in series. Upon this occasion, devices from the exhaust gas extractor to the first processing device and valves, which are provided in each of reactors, are arranged in series, on one hand, but valves at the downstream side join one another by one pipeline, and are connected to a stack through a total gaseous waste processing device, on another. (Yoshihara, H.)

  19. Decree no 96-761 from August 27, 1996 authorizing the company for industrial wastes and effluents conditioning to create a basic nuclear installation, named Centraco, in the town of Codolet (Gard department)

    International Nuclear Information System (INIS)

    Juppe, A.; Borotra, F.; Lepage, C.

    1996-01-01

    This decree from the French prime minister, the minister of environment and the minister of industry and postal services gives permission to the Socodei company to create a basic nuclear installation, named Centraco, in the town of Codolet (Gard department, France) for the selection, decontamination, valorization, treatment and conditioning of low radioactive effluents and wastes from French and foreign industries. The decree describes the Centraco installation (buildings, incineration and storage unit, maintenance unit). It summarizes the technical rules which must be applied concerning the quality assurance, the protection against risks of radioactive or chemical materials dissemination, the personnel and public protection against ionizing radiations, the control of environmental pollution with liquid and gaseous effluents, the reduction of volume and radioactivity of solid wastes, the transport and handling of radioactive materials, the protection against earthquakes and fire, the safety systems for plant operation, and the personnel training. (J.S.)

  20. Model, parameter and code of environmental dispersion of gaseous effluent under normal operation from nuclear power plant with 600 MWe

    International Nuclear Information System (INIS)

    Hu Erbang; Gao Zhanrong

    1998-06-01

    The model of environmental dispersion of gaseous effluence under normal operation from a nuclear power plant with 600 MWe is established to give a mathematical expression of annual mean atmospheric dispersion factor under mixing release condition based on quality assessment of radiological environment for 30 years of Chinese nuclear industry. In calculation, the impact from calm and other following factors have been taken into account: mixing layer, dry and wet deposition, radioactive decay and buildings. The doses caused from the following exposure pathways are also given by this model: external exposure from immersion cloud and ground deposition, internal exposure due to inhalation and ingestion. The code is named as ROULEA. It contains four modules, i.e. INPUT, ANRTRI, CHIQV and DOSE for calculating 4-dimension joint frequency, annual mean atmospheric dispersion factor and doses

  1. PERFIL FÍSICO-QUÍMICO DE AGUARDENTE DE CANA-DEAÇÚCAR PRODUZIDA POR METODOLOGIAS DE DUPLA DESTILAÇÃO EM ALAMBIQUE SIMPLES

    Directory of Open Access Journals (Sweden)

    André Ricardo ALCARDE

    2010-03-01

    Full Text Available

    O objetivo deste trabalho foi determinar o perfil físico-químico da aguardente de cana-de-açúcar produzida por diferentes metodologias de dupla destilação em alambique simples. Mosto fermentado de caldo de cana-deaçúcar foi destilado em alambique simples seguindo três metodologias de dupla destilação: a empregada para a produção de conhaque, a empregada na produção de uísque e a metodologia da proporção porcentual 10-80-10, referente aos volumes das frações “cabeça”, “coração” e “cauda” do destilado da segunda destilação. Para comparação, também foi produzida uma aguardente de cana-de-açúcar monodestilada. Os destilados foram analisados quimicamente quanto às concentrações de etanol, cobre, acidez volátil, furfural e hidroximetilfurfural, aldeídos, ésteres, metanol e álcoois superiores. As aguardentes de cana-de-açúcar foram também avaliadas sensorialmente quanto aos atributos de aroma, sabor e preferência. Comparada com a monodestilação, a dupla destilação melhorou a qualidade química das aguardentes, pois proporcionou redução das concentrações de cobre, de acidez volátil, de aldeídos, de ésteres, de metanol, de álcoois superiores e, consequentemente, do coeficiente de congêneres das aguardentes. As metodologias de dupla destilação baseadas na produção de conhaque e de uísque proporcionaram maior redução na concentração dos componentes secundários das aguardentes que a metodologia baseada na proporção 10-80-10. A dupla destilação melhorou também a qualidade sensorial das aguardentes, pois, independentemente da metodologia empregada, as aguardentes produzidas por dupla destilação obtiveram maior aceitação sensorial que a aguardente monodestilada. Dentre as aguardentes duplamente destiladas, a produzida segundo a metodologia do uísque obteve as maiores notas dos provadores quanto aos parâmetros de aroma e sabor e também foi a mais preferida.

  2. 200 Area Liquid Effluent Facilities -- Quality assurance program plan

    International Nuclear Information System (INIS)

    Fernandez, L.

    1995-01-01

    This Quality Assurance Program Plan (QAPP) describes the quality assurance and management controls used by the 200 Area Liquid Effluent Facilities (LEF) to perform its activities in accordance with DOE Order 5700.6C. The 200 Area LEF consists of the following facilities: Effluent Treatment Facility (ETF); Treated Effluent Disposal Facility (TEDF); Liquid Effluent Retention facility (LERF); and Truck Loading Facility -- (Project W291). The intent is to ensure that all activities such as collection of effluents, treatment, concentration of secondary wastes, verification, sampling and disposal of treated effluents and solids related with the LEF operations, conform to established requirements

  3. 40 CFR 417.163 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Detergents Subcategory § 417.163 Effluent limitations guidelines representing the degree... subpart after application of the best available technology economically achievable: (a) For normal liquid...

  4. 40 CFR 428.62 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Effluent limitations guidelines... technology currently available. 428.62 Section 428.62 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS RUBBER MANUFACTURING POINT SOURCE CATEGORY Medium...

  5. 40 CFR 428.63 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Effluent limitations guidelines... economically achievable. 428.63 Section 428.63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS RUBBER MANUFACTURING POINT SOURCE CATEGORY Medium-Sized General...

  6. Attachment of gaseous fission products to aerosols

    International Nuclear Information System (INIS)

    Skyrme, G.

    1985-01-01

    Accidents may occur in which the integrity of fuel cladding is breached and volatile fission products are released to the containment atmosphere. In order to assess the magnitude of the subsequent radiological hazard it is necessary to know the transport behaviour of such fission products. It is frequently assumed that the fission products remain in the gaseous phase. There is a possibility, however, that they may attach themselves to particles and hence substantially modify their transport properties. This paper provides a theoretical assessment of the conditions under which gaseous fission products may be attached to aerosol particles. Specific topics discussed are: the mass transfer of a gaseous fission product to an isolated aerosol particle in an infinite medium; the rate at which the concentration of fission products in the gas phase diminishes within a container as a result of deposition on a population of particles; and the distribution of deposited fission product between different particle sizes in a log-normal distribution. It is shown that, for a given mass, small particles are more efficient for fission product attachment, and that only small concentrations of such particles may be necessary to achieve rapid attachment. Conditions under which gaseous fission products are not attached to particles are also considered, viz, the competing processes of deposition onto the containment walls and onto aerosol particles, and the possibility of the removal of aerosols from the containment by various deposition processes, or agglomeration, before attachment takes place. (author)

  7. Effluent monitoring: Its purpose and value

    International Nuclear Information System (INIS)

    Schoen, A.A.

    1978-01-01

    The purpose of effluent monitoring is described in terms of the primary objectives, the most important of which is to verify that the facility is functioning as it was designed and that the waste treatment and effluent control systems are performing as planned and expected. The object of a monitoring programme should be periodically re-examined to ensure that the programme serves a contemporary purpose. The value of the effluent monitoring programme is determined by the extent to which users of the monitoring data, i.e. the operator, the regulating authorities and the public, accept the result as indicating that the plant is operating safely, and in an environmentally acceptable manner. The credibility of the monitoring results is therefore the most important factor determining the value of an effluent monitoring programme. (author)

  8. Assessment of effluent turbidity in mesophilic and thermophilic sludge reactors - origin of effluent colloidal material

    NARCIS (Netherlands)

    Vogelaar, J.C.T.; Lier, van J.B.; Klapwijk, B.; Vries, M.C.; Lettinga, G.

    2002-01-01

    Two lab-scale plug flow activated sludge reactors were run in parallel for 4 months at 30 and 55°C. Research focussed on: (1) COD (chemical oxygen demand) removal, (2) effluent turbidity at both temperatures, (3) the origin of effluent colloidal material and (4) the possible role of protozoa on

  9. Desalination of effluent using fin type solar still

    Energy Technology Data Exchange (ETDEWEB)

    Velmurugan, V. [Department of Mechanical Engineering, Infant Jesus College of Engineering, Thoothukudi, Tamil Nadu 628 851 (India); Deenadayalan, C.K.; Vinod, H.; Srithar, K. [Department of Mechanical Engineering, Thiagarajar College of Engineering, Madurai, Tamil Nadu 625 015 (India)

    2008-11-15

    In this work, an attempt is made to produce potable water from industrial effluents. An ordinary basin type solar still integrated with fins at the basin plate is used for experimentation. Since industrial effluent is used as feed, before this still, an effluent settling tank is provided to get clarified effluent. This effluent settling tank is fabricated with three chambers, consists of pebble, coal and sand for settling the impurities and removing the bacteria in the effluents. Sponges, pebbles, black rubber and sand are used in the fin type single basin solar still for enhancing the yield. Results show that the productivity increases considerably due to this modification. A theoretical analysis is also carried out which, closely converges with experimental results. The economic analysis proved that the approximate payback period of such kinds of still is 1 year. (author)

  10. 40 CFR 424.13 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... representing the degree of effluent reduction attainable by the application of the best available technology economically achievable. 424.13 Section 424.13 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Furnaces With Wet Air Pollution Control Devices Subcategory § 424.13 Effluent limitations guidelines...

  11. 40 CFR 424.43 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... representing the degree of effluent reduction attainable by the application of the best available technology economically achievable. 424.43 Section 424.43 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Carbide Furnaces With Wet Air Pollution Control Devices Subcategory § 424.43 Effluent limitations...

  12. 40 CFR 429.163 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Science.gov (United States)

    2010-07-01

    ... degree of effluent reduction attainable by the application of the best available technology economically... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS TIMBER PRODUCTS PROCESSING POINT SOURCE CATEGORY Wood Furniture... application of the best available technology economically achievable (BAT). Except as provided in 40 CFR 125...

  13. 40 CFR 429.171 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Science.gov (United States)

    2010-07-01

    ... degree of effluent reduction attainable by the application of the best practicable control technology... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS TIMBER PRODUCTS PROCESSING POINT SOURCE CATEGORY Wood Furniture... best practicable control technology currently available (BPT). Except as provided in 40 CFR 125.30...

  14. 40 CFR 429.173 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Science.gov (United States)

    2010-07-01

    ... degree of effluent reduction attainable by the application of the best available technology economically... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS TIMBER PRODUCTS PROCESSING POINT SOURCE CATEGORY Wood Furniture... best available technology economically achievable (BAT). Except as provided in 40 CFR 125.30 through...

  15. 40 CFR 429.161 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Science.gov (United States)

    2010-07-01

    ... degree of effluent reduction attainable by the application of the best practicable control technology... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS TIMBER PRODUCTS PROCESSING POINT SOURCE CATEGORY Wood Furniture... application of the best practicable control technology currently available (BPT). Except as provided in 40 CFR...

  16. 40 CFR 426.123 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS GLASS MANUFACTURING POINT SOURCE CATEGORY Incandescent Lamp... technology economically achievable: (a) [Reserved] (b) Any manufacturing plant which frosts incandescent lamp... characteristic Effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days shall...

  17. Drogas: uma proposta de metodologia da problematização no Ensino de Química

    Directory of Open Access Journals (Sweden)

    Rafaela Alves de Andrade

    2018-03-01

    Full Text Available A metodologia da problematização é algo transformador que desperta a curiosidade do aluno e o desafia a observar a realidade, entender e modificá-la. Assim, o aluno consegue encontrar um estímulo para aprender, no qual o professor é o mediador do conhecimento nessa educação problematizadora. O estudo teve como objetivo analisar a utilização da metodologia da problematização nas aulas de química, em uma turma do 3° ano do ensino médio, analisando o desenvolvimento da aprendizagem dos conceitos de química presentes no tema: as drogas. A investigação ocorreu de forma qualitativa com fins descritivos e explicativos na abordagem do problema, com aplicação de questionários como instrumento de coleta de dados, para analisar o conhecimento dos estudantes no início e final do estudo. O processo de intervenção foi realizado nas aulas de química aplicando as etapas do Arco de Maguerez, no qual ocorreu em cinco momentos: observação da realidade, pontos-chave, teorização, hipóteses de solução e aplicação à realidade. Ao ser executada essa metodologia, verificou- se que os alunos adquirem estímulos para aprenderem com aulas problematizadoras através de um tema social.

  18. Treatment of effluent at the Saclay Centre d'Etudes Nucleaires (1960); Le traitement des effluents du Centre d'Etudes Nucleaires de Saclay (1960)

    Energy Technology Data Exchange (ETDEWEB)

    Wormser, G [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    The Centre d'Etudes Nucleaires at Saclay possesses several installations from which liquid radioactive effluent is rejected, and it has thus been found necessary to construct a station for the purification of radioactive liquids and to settle various chemical, analytical and technological problems. This report describes, in the following order: - the disposal possibilities at the Centre d'Etudes Nucleaires, Saclay, - the effluents produced at the centre, - the set-up for collecting effluent, - treatment of the effluent, - results of these treatments. (author) [French] La presence, au Centre d'Etudes Nucleaires de Saclay, de plusieurs installations susceptibles de rejeter des effluents liquides radioactifs a necessite la construction d'une station d'epuration d'eaux radioactives et la mise au point de differents problemes chimiques, analytiques et technologiques. Dans ce rapport, nous exposerons successivement: - les possibilites de rejet du Centre d'Etudes Nucleaires de Saclay, - les effluents du centre, - le dispositif de collecte des effluents, - le traitement de ces effluents, - les resultats de ces traitements. (auteur)

  19. Secondary incinerator for radioactive gaseous waste

    International Nuclear Information System (INIS)

    Takeda, Tadashi; Masuda, Takashi.

    1997-01-01

    A vessel incorporated with packings, in which at least either of the packings and the vessel is put to induction-heating by high frequency induction coils, is disposed in a flow channel of radioactive gaseous wastes exhausted from a radioactive waste incinerator. The packings include metals such as stainless pipes and electroconductive ceramics such as C-SiC ceramics. Since only electricity is used as an energy source, in the secondary incinerator for the radioactive gaseous wastes, it can be installed in a cell safely. In addition, if ceramics are used, there is no worry of deterioration of the incinerator due to organic materials, and essential functions are not lowered. (T.M.)

  20. 40 CFR 424.23 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... representing the degree of effluent reduction attainable by the application of the best available technology economically achievable. 424.23 Section 424.23 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Furnaces and Other Smelting Operations With Wet Air Pollution Control Devices Subcategory § 424.23 Effluent...

  1. 40 CFR 406.17 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... control technology. 406.17 Section 406.17 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 406.17 Effluent limitations guidelines representing the degree of effluent reduction attainable by the...] Effective Date Note: Section 406.17 was indefinitely suspended at 45 FR 45582, July 7, 1980. ...

  2. Gaseous detectors for energy dispersive X-ray fluorescence analysis

    Science.gov (United States)

    Veloso, J. F. C. A.; Silva, A. L. M.

    2018-01-01

    The energy resolution capability of gaseous detectors is being used in the last years to perform studies on the detection of characteristic X-ray lines emitted by elements when excited by external radiation sources. One of the most successful techniques is the Energy Dispersive X-ray Fluorescence (EDXRF) analysis. Recent developments in the new generation of micropatterned gaseous detectors (MPGDs), triggered the possibility not only of recording the photon energy, but also of providing position information, extending their application to EDXRF imaging. The relevant features and strategies to be applied in gaseous detectors in order to better fit the requirements for EDXRF imaging will be reviewed and discussed, and some application examples will be presented.

  3. Evaluation of genotoxicity of liquid effluents from gas washing systems by means of bioassay Trad-MCN

    International Nuclear Information System (INIS)

    Machado, Alessandra Carla Fattori Ergesse; Alves, Edenise Segala

    2007-01-01

    In the gas washing systems the gaseous emissions from a facility are forced through an absorbing liquid preventing pollutants to be dispersed into the atmosphere. In the Centro Tecnologico da Marinha em Sao Paulo/Centro Experimental Aramar (CEA), the gas washing are used to control the emissions from the uranium enrichment facilities. Uranium. fluoride, ammonia and hydrogen fluoride are the main contaminants, all heavily toxic. Biological assays, using plants or other living organisms, have been used to assess genotoxic agents in the environment. Among the bioassays using plants, the Trad-MCN has been used extensively, as it allows the evaluation of liquid or gaseous contaminants. The species Tradescantia pallida (Rose) was exposed in a dynamic system to liquid effluents from CEA. A positive control was the exposure to formaldehyde 10% in water, known as a very toxic solution, and the negative control was the exposure to filtered air. The protocol established by Ma (1983) for hybrid clones and validated for the T. pallida by Guimaraes (2003) was used to perform the Trad-MCN assays. Only preparations containing early tetrads were scored. In that context, the present study objectifies to evaluate, by the Trad-MCN bioassay, the genotoxicity of the solution from the gas washing and, also, evaluate the efficiency of that system. The results obtained show that the T. pallida is a sensitive bioindicator for the pollutants tested and can be useful for in vitro environmental monitoring under controlled conditions. (author)

  4. Evaluation of genotoxicity of liquid effluents from gas washing systems by means of bioassay Trad-MCN

    Energy Technology Data Exchange (ETDEWEB)

    Machado, Alessandra Carla Fattori Ergesse [Centro Tecnologico da Marinha em Sao Paulo (CTMSP), SP (Brazil). Div. de Monitoracao Ambiental], E-mail: alessandra@ctmsp.mar.mil.br; Alves, Edenise Segala [Instituto de Botanica de Sao Paulo, SP (Brazil). Secao de Anatomia], E-mail: ealves@ibot.sp.gov.br

    2007-07-01

    In the gas washing systems the gaseous emissions from a facility are forced through an absorbing liquid preventing pollutants to be dispersed into the atmosphere. In the Centro Tecnologico da Marinha em Sao Paulo/Centro Experimental Aramar (CEA), the gas washing are used to control the emissions from the uranium enrichment facilities. Uranium. fluoride, ammonia and hydrogen fluoride are the main contaminants, all heavily toxic. Biological assays, using plants or other living organisms, have been used to assess genotoxic agents in the environment. Among the bioassays using plants, the Trad-MCN has been used extensively, as it allows the evaluation of liquid or gaseous contaminants. The species Tradescantia pallida (Rose) was exposed in a dynamic system to liquid effluents from CEA. A positive control was the exposure to formaldehyde 10% in water, known as a very toxic solution, and the negative control was the exposure to filtered air. The protocol established by Ma (1983) for hybrid clones and validated for the T. pallida by Guimaraes (2003) was used to perform the Trad-MCN assays. Only preparations containing early tetrads were scored. In that context, the present study objectifies to evaluate, by the Trad-MCN bioassay, the genotoxicity of the solution from the gas washing and, also, evaluate the efficiency of that system. The results obtained show that the T. pallida is a sensitive bioindicator for the pollutants tested and can be useful for in vitro environmental monitoring under controlled conditions. (author)

  5. Facility effluent monitoring plan for the B plant

    International Nuclear Information System (INIS)

    Lesser, J.E.

    1994-09-01

    A facility effluent monitoring plan is required by the U.S. Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438-1. This facility effluent monitoring plant assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated every three years

  6. Astrophysics of gaseous nebulae and active galactic nuclei

    International Nuclear Information System (INIS)

    Osterbrock, D.E.

    1989-01-01

    A graduate-level text and reference book on gaseous nebulae and the emission regions in Seyfert galaxies, quasars, and other types of active galactic nuclei (AGN) is presented. The topics discussed include: photoionization equilibrium, thermal equilibrium, calculation of emitted spectrum, comparison of theory with observations, internal dynamics of gaseous nebulae, interstellar dust, regions in the galactic context, planetary nebulae, nova and supernova remnants, diagnostics and physics of AGN, observational results on AGN

  7. Primary effluent filtration for coastal discharges

    Energy Technology Data Exchange (ETDEWEB)

    Cooper-Smith, G.D. [Yorkshire Water Services, Huddersfield (United Kingdom); Rundle, H. [The Capital Controls Group, Nottingham (United Kingdom)

    1998-12-31

    The use of a Tetra Deep Bed filter demonstration unit to treat primary effluent (Primary Effluent Filtration, PEF) was investigated. PEF proved capable of achieving the UWWTD primary standard, even when the primary stage performs poorly, but is not a cost-effective alternative to chemically assisted settlement. Results demonstrated that using a 1.5 to 2.2 mm grade medium, a filtration rate of 5 m/h, three backwashes a day and dosing 40 mg/l of PAXXL60 (a polyaluminium silicte) an average effluent quality of 20 mg/l BOD and 15 mgl/l total solid could be achieved. UV disinfection produced an effluent which complied with the Bathing Water Directive imperative requirement. A high enterovirus kill was also achieved. However, considerable additional work would be required before PEF could be considered suitable for full-scale applications. (orig.)

  8. Metodologias de ensino e formação na área da saúde: revisão de literatura

    OpenAIRE

    Mello, Carolina de Castro Barbosa; Alves, Renato Oliveira; Lemos, Stela Maris Aguiar

    2014-01-01

    A Educação em Saúde no Ensino Superior tem sido objeto de muitos debates acerca da formação profissional em saúde. Portanto, há a discussão eminente acerca da utilização de novas metodologias de ensino a fim de formar profissionais em saúde, com habilidades e competências além do domínio técnico-científico, que sejam capazes de criar, planejar, implementar e avaliar políticas e ações em saúde para a população e, ao mesmo tempo, solucionar problemas. Para isso, metodologias ativas de aprendiza...

  9. Some aspects of dose evaluation, 3

    International Nuclear Information System (INIS)

    Yoshida, Yoshikazu

    1979-01-01

    This paper describes methods of calculating the radioiodine releases and resultant doses in the ''Guide for calculation of doses to man from routine releases of effluents from light-water-cooled nuclear power plants for evaluating compliance with dose objectives around a site of LWRs'' by the Japan Nuclear Safety Commission. Examples of dose calculation in the design stage of plants and releases of radioiodine from operating plants are also given. The thyroid dose objective from radioiodine in reactor effluents was determined to be 15 mrem per year by the AEC of Japan in 1975. In the guide, models and parameters are given as most realistic on the basis of current knowledge and experience; in cases involving unknown factors these are on conservative side. Calculations of annual average releases of gaseous and liquid effluents are made using the models and parameters established through operational experiences of the LWR plants. Annual thyroid doses are calculated from inhalation and ingestion of leafy vegetable and cow's milk for gaseous effluents and ingestion of marine food for liquid effluents. In calculation of the thyroid dose, fw = 0.2 is used instead of = 0.3 in ICRP publ. 2 for ingestion of foods excluding seaweed and the specific activity method for ingestion of foods including seaweed. It is because Japanese take foods with much stable iodine. Calculated annual releases of 131 I in gaseous effluents of typical BWR (1100 MWe) and PWR (800 MWe) are about 2 Ci and 0.7 Ci per year per plant and the annual thyroid doses are about 4 mrem and 9 mrem per year, respectively. Actually, however, releases of 131 I in gaseous effluents from the operating LWR plants are about less than one tenth of the above figures. (author)

  10. MAPS-15504 - Uma metodologia automatizada para avaliação de processo de software

    Directory of Open Access Journals (Sweden)

    Itana Maria de Souza Gimenes

    2000-05-01

    Full Text Available Devido às crescentes exigências por qualidade, a comunidade de engenharia de software tem produzido diversas normas e apresentado diversas abordagens sobre a qualidade dos produtos e processos de software. Grande parte dessas normas são aplicadas ao processo de software, dentre os quais se destacam pela larga utilização a ISO 9000-3, a ISO 12207, o CMM e o ISO/IEC TR 15504 (resultado dos trabalhos do projeto SPICE. Outro resultado das pesquisas da comunidade de engenharia de software são os ambientes de engenharia de software centrados em processo (PSEE, os quais visam à automação do processo de software. Este artigo apresenta MAPS-15504, uma metodologia automatizada para avaliação da qualidade do processo de software baseada no ISO/IEC TR 15504. A metodologia de avaliação de processo de software foi aplicada a um estudo de caso e implementada no ambiente do ExPSEE, um ambiente experimental desenvolvido no Departamento de Informática (DIN da Universidade Estadual de Maringá (UEM

  11. Facility effluent monitoring plan for 242-A evaporator facility

    International Nuclear Information System (INIS)

    Crummel, G.M.; Gustavson, R.D.

    1995-02-01

    A facility effluent monitoring plan is required by the U.S. Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could affect employee or public safety or the environment. A facility effluent monitoring plan determination was performed during Calendar Year 1991 and the evaluation showed the need for a facility effluent monitoring plan. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438-1. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated, as a minimum, every three years

  12. 40 CFR 458.43 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... this paragraph, which may be discharged from the carbon black lamp process by a point source subject to... Lamp Process Subcategory § 458.43 Effluent limitations guidelines representing the degree of effluent... achievable: There shall be no discharge of process waste water pollutants to navigable waters. ...

  13. Facility effluent monitoring plan for 242-A Evaporator facility

    International Nuclear Information System (INIS)

    Crummel, G.M.; Gustavson, R.D.

    1993-03-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1* for any operations that involve hazardous materials and radioactive substances that could affect employee or public safety or the environment. A facility effluent monitoring plan determination was performed during Calendar Year 1991 and the evaluation showed the need for a facility effluent monitoring plan. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility effluent Monitoring Plans, WHC-EP-0438-1**. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements

  14. A PRODUÇÃO DE MATERIAL DIDÁTICO PARA O ENSINO SUPERIOR BASEADA NA METODOLOGIA DE SALA DE AULA INVERTIDA

    Directory of Open Access Journals (Sweden)

    Rafael Dias Rios de Souza

    2016-11-01

    Full Text Available Este estudo tem como objetivo discutir uma proposta nova de metodologia de ensino-aprendizagem, que será utilizada no ambiente de uma instituição de ensino. Essa proposta tem como base o uso de ferramentas tecnológicas e inovadoras, tais como o procedimento pedagógico denominado Flipped classroom, ou sala de aula invertida. Neste trabalho, apresentamos uma aplicabilidade da metodologia em uma na disciplina  Universidade do Vale do Paraíba (UNIVAP, com a finalidade de coletar e processar dados para entender como novas tecnologias vem influenciando o meio educacional.

  15. 40 CFR 406.27 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... control technology (BCT). 406.27 Section 406.27 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 406.27 Effluent limitations guidelines representing the degree of effluent reduction attainable by the... conventional pollutants (which are defined in § 401.16) in § 406.22 of this subpart for the best practicable...

  16. 40 CFR 406.47 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... control technology (BCT). 406.47 Section 406.47 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Subcategory § 406.47 Effluent limitations guidelines representing the degree of effluent reduction attainable... specified for conventional pollutants (which are defined in § 401.16) in § 406.42 of this subpart for the...

  17. 40 CFR 406.37 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... control technology (BCT). 406.37 Section 406.37 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Subcategory § 406.37 Effluent limitations guidelines representing the degree of effluent reduction attainable... specified for conventional pollutants (which are defined in § 401.16) in § 406.32 of this subpart for the...

  18. 40 CFR 417.153 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... operation of spray drying towers as defined above, the following values pertain: Effluent characteristic...) 1 Within the range 6.0 to 9.0. (b) For air quality restricted operation of a spray drying tower, but... Manufacture of Spray Dried Detergents Subcategory § 417.153 Effluent limitations guidelines representing the...

  19. Biodenitrification of gaseous diffusion plant aqueous wastes: stirred bed reactor

    International Nuclear Information System (INIS)

    Holland, M.E.

    1980-01-01

    Approximately 30 kilograms of nitrates per day are discarded in the raffinates (acid wastes) of the Portsmouth Gaseous Diffusion Plant's X-705 Uranium Recovery and Decontamination Facility. A biodenitrification process employing continuous-flow, stirred-bed reactors has been successfully used to remove nitrates from similar acid wastes at the Oak Ridge Y-12 Plant. Laboratory studies have been made at Portsmouth to characterize the X-705 raffinates and to test the stirred-bed biodenitrification process on such raffinates. Raffinates which had been previously characterized were pumped through continuous-flow, stirred-bed, laboratory-scale reactors. Tests were conducted over a period of 146 days and involved variations in composition, mixing requirements, and the fate of several metal ions in the raffinates. Tests results show that 20 weight percent nitrates were reduced to a target nitrate effluent concentration of 100 μg/ml with a 99.64 percent efficiency. However, the average denitrification rate achieved was only 33% of that demonstrated with the Y-12 stirred-bed system. These low rates were probably due to the toxic effects of heavy metal ions on the denitrifying bacteria. Also, most of the uranium in the raffinate feed remained in the biomass and calcite, which collected in the reactor. This could cause criticality problems. For these reasons, it was decided not to make use of the stirred-bed bioreactor at Portsmouth. Instead, the biodenitrification installation now planned will use fluidized bed columns whose performance will be the subject of a subsequent report

  20. Avaliação de Micro e Pequenas Empresas Utilizando a Metodologia Multicritério e o Método do Fluxo de Caixa Descontado

    Directory of Open Access Journals (Sweden)

    Marcus Vinicius Andrade de Lima

    2010-01-01

    Full Text Available Neste artigo é apresentada uma contribuição ao método do fluxo de caixa descontado utilizando a metodologia multicritério de apoio à decisão. Essa metodologia incorpora variáveis de natureza qualitativa e subjetiva ao método tradicional do fluxo de caixa descontado utilizado na avaliação de empresas. Para ilustrar o método proposto foi realizado um estudo descritivo de natureza exploratória aplicado a um multicaso. A intervenção foi em Micro e Pequenas Empresas (MPE do ramo químico, farmacêutico e de turismo. Como resultado, o avaliador ajustou o preço do negócio levando em conta a resultante da mixagem entre as duas metodologias.

  1. Diferentes metodologias aplicadas ao ensino de astronomia no Ensino Médio

    Science.gov (United States)

    Albrecht, E.; Voelzke, M. R.

    2009-03-01

    O presente trabalho de intervenção foi realizado junto à Escola Estadual Colònia dos Pescadores na cidade de Caraguatatuba, com très turmas do terceiro ano do Ensino Médio, envolvendo 119 alunos com idades entre 16 e 19 anos. A fase inicial foi composta de um questionário de vinte questíes dissertativas e objetivas, aplicado pelo professor titular da sala, que era o mesmo nas très turmas, para diagnosticar nos educandos os conceitos prévios sobre Astronomia e, partindo destes realizar um trabalho de intervenção nas classes envolvidas utilizando, em cada uma, metodologias diferentes: (A) sob forma de seminários, elaborados e apresentados pelos educandos, no qual o educador faz apenas as intervençíes necessárias; (B) de forma tradicional, com auxílio de multimídias para desenvolvimento das aulas e a terceira (C) tradicional, fazendo uso exclusivo de lousa e giz. Ao final do trabalho os alunos responderam novamente o questionário inicial para diagnosticar dentre as très metodologias utilizadas qual apresentou melhores aplicaçíes, os resultados iniciais foram comparados com os finais. Quando questionados a respeito do significado de Astronomia observou-se inicialmente que os acertos na turma A foram de 100%, turma B: 64%, turma C: 84%, após a intervenção os acertos foram: 100%, 97% e 85% respectivamente, demonstrando que houve um avanço significativo na turma B, a turma A manteve seu índice e a turma C evoluiu, porém não tanto quanto a B. Quando interrogados sobre quantos planetas vocè acha que existem em nosso Sistema Solar? os acertos foram: turma A: 39%, turma B: 48% e turma C: 46%, após o desenvolvimento do trabalho os acertos foram 94%, 97% e 90% respectivamente. Dentro das respostas obtidas observa-se que a metodologia tradicional com o auxílio de multimeios, aplicada na turma B, demonstrou melhores resultados, sendo a mais significativa. Outra conclusão muito importante é que apesar de o tema Astronomia ser amplamente

  2. Facility Effluent Monitoring Plan for the N Reactor

    International Nuclear Information System (INIS)

    Watson, D.J.; Brendel, D.F.; Shields, K.D.

    1991-11-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP- 0438. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan is the first annual report. It shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated as a minimum every three years. The primary purpose of the N Reactor Facility Effluent Monitoring Plan (FEMP), during standby, is to ensure that the radioactive effluents are properly monitored and evaluated for compliance with the applicable DOE orders and regulatory agencies at the federal, state, and local levels. A secondary purpose of the FEMP is to ensure that hazardous wastes are not released, in liquid effluents, to the environment even though the potential to do so is extremely low. The FEMP is to provide a monitoring system that collects representative samples in accordance with industry standards, performs analyses within stringent quality control (QC) requirements, and evaluates the data through the use of comparative analysis with the standards and acceptable environmental models

  3. 40 CFR 436.42 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... Industrial Sand Subcategory § 436.42 Effluent limitations guidelines representing the degree of effluent... 6.0 and water quality criteria in water quality standards approved under the Act authorize such lower pH, the pH limitation for such discharge may be adjusted downward to the pH water quality...

  4. Portsmouth Gaseous Diffusion Plant expansion: final environmental statement. Volume 2. Appendices. [Appendices only

    Energy Technology Data Exchange (ETDEWEB)

    Liverman, James L.

    1977-09-01

    Volume 2 is comprised of appendices: Portsmouth Gaseous Diffusion Plant Existing Facilities; Ecology; Civic Involvement; Social Analysis; Population Projections; Toxicity of Air Pollutants to Biota at Portsmouth Gaseous Diffusion Plant; and Assessment of Noise Effects of an Add-On to the Portsmouth Gaseous Diffusion Plant. (LK)

  5. Decree of July 23, 2008 dealing with the approval of the decision no 2008-DC-00925 taken by the Nuclear Safety Authority on January 29, 2008 and defining the technical rules which must be complied with by the elimination of effluents or wastes either contaminated or likely to be contaminated by radionuclides because of a nuclear activity, and taken according to arrangements of R. 1333-12 article of the Public Health Code

    International Nuclear Information System (INIS)

    Visseaux, H.; Tronel, C.

    2008-01-01

    The authors present the scope of application of the decree, and then discuss the main regulatory evolutions with respect to a service instruction published in 2001. The main evolutions concern the introduction of contaminated waste area, the drafting of a management plan, an annual reporting to the ANDRA, the abrogation of the minimum surface for contaminated waste storing areas, the modification of the threshold value of liquid effluents before their release, the abrogation of a threshold value for gaseous effluents, the possibility of releasing effluents containing radionuclides having a period greater than 100 days, the arrangement of a permanent access enabling measurement and sampling devices to be installed in the sanitation network. A table describes the implementation schedule for this decree

  6. Some aspects of numerical analysis of turbulent gaseous and spray combustion

    International Nuclear Information System (INIS)

    Takagi, T.

    1991-01-01

    In this paper numerical calculations and analysis on turbulent non-premixed gaseous and spray combustion are reviewed. Attentions were paid to the turbulent flow and combustion modeling applicable to predicting the flow, mixing and combustion of gaseous fuels and sprays. Some of the computed results of turbulent gaseous non-premixed (diffusion) flames with and without swirl and transient spray combustion were compared with experimental ones to understand the processes in the flame and to assure how the computations predict the experiments

  7. Treatment of effluents in uranium industry

    International Nuclear Information System (INIS)

    Ghosh, S.K.

    2009-01-01

    Uranium processing technology in India has matured in the last 50 years and is able to meet the country's requirement. Right from mining of the ore to milling and refining, effluents are generated and are being processed for their safe disposal. While the available technology is able to meet the regulatory limits of the effluents, the same may not be enough to meet the increased demand of uranium in the future. The increased population, urbanization and climate change are not only going to decrease the supply of process water but will also place increased restrictions on disposal to environment. This demands technologies that will generate less effluent for disposal and enable reuse and recycle concept to the extent possible. Presently used conventional physical-chemical methods, to contain the contaminants would, therefore, require further refinements. Contaminants like sulfates, chlorides etc in the effluent of uranium mill based on acid leach process are the concerns for the future plants. Hence, there is an urgent need for development of suitable methods for maximum recycle of the process effluents, which will also enable in minimizing the consumption of process water. A suitable membrane based process can be an option leaving a concentrated brine for reuse or for further treatment and disposal

  8. Potential for reuse of effluent from fish-processing industries

    Directory of Open Access Journals (Sweden)

    Luana Morena Rodrigues Vitor Dias Ferraciolli

    2017-09-01

    Full Text Available The most common problems in the fish processing industry relate to high water consumption and the generation of effluents with concentrated organic loads. Given that reuse can represent an alternative for sustainable development, this study sought to assess the potential for recycling effluents produced in a fish-processing plant. In order to do so, the final industrial effluent was analyzed using the American Public Health Association (APHA standard effluent-analysis method (2005. In addition, the study assessed treatments which produce effluents meeting the requirements prescribed by different countries' regulations for reuse and recycling. The results found that effluents with smaller organic loads, such as those from health barriers and monoblock washing, can be treated in order to remove nutrients and solids so that they can be subsequently reused. For effluents produced by the washing and gutting cylinders, it is recommended that large fragments of solid waste be removed beforehand. Effluents can in this way attain a quality compatible with industrial reuse. This study further highlights the possibility of treating effluents so as comply with drinking water standards. This would potentially allow them to be used within the actual fish-processing procedure; in such a case, a revision of standards and measures for controlling use should be considered to prevent microbiological damage to products and risks to handlers and final consumers.

  9. Gaseous diffusion system

    International Nuclear Information System (INIS)

    Garrett, G.A.; Shacter, J.

    1978-01-01

    A gaseous diffusion system is described comprising a plurality of diffusers connected in cascade to form a series of stages, each of the diffusers having a porous partition dividing it into a high pressure chamber and a low pressure chamber, and means for combining a portion of the enriched gas from a succeeding stage with a portion of the enriched gas from the low pressure chamber of each stage and feeding it into one extremity of the high pressure chamber thereof

  10. Effect of air infiltration in the reactor refrigerant on the radiation measurement systems of gaseous effluents treatment

    International Nuclear Information System (INIS)

    Zorrilla, S.; Padilla, I.

    1991-01-01

    The system of treatment of gassy effluents of the CLV, well-known as the off-gas this gifted one in turn of a mensuration system and registration (monitoring) that consists of diverse established radiation monitors in the discharge point to the atmosphere and in other intermediate points of the process. The purpose of the monitoring system is to maintain continually informed to the operators about the effectiveness of the treatment system, to take registrations of the total quantity of liberated radioactive materials and to give warning by means of an alarm system of any abnormal situation that could end in an approach to the limits marked by the technical specifications. In September 1989 an event happened in the one that the high alarms corresponding to the post-treatment of the off-gas were activated. For this situation the personnel proceeded to diminish the power of the reactor to be able to investigate the causes that gave place to the event. It was observed that the alarms of the monitor were activated by significant infiltrations of air in the primary circuit of the refrigerant, for what it was proceeded to enlarge the scales of the implied monitor or to reduce the sensibility of their readings

  11. Radiation-adsorption purification of effluents containing pesticides

    International Nuclear Information System (INIS)

    Brusentseva, S.A.; Shubin, V.N.; Nikonorova, G.K.; Zorin, D.M.; Sosnovskaya, A.A.; Petryaev, E.P.; Vlasova, V.I.; Edimicheva, I.P.; Subbotina, N.N.; Belorusskij Gosudarstvennyj Univ., Minsk)

    1986-01-01

    The radiation-adsorption purification is one of the new direction in the radiation purification of natural wastes and effluents containing pesticides. This method combines the conventional adsorption purification with radiation treatment of the sorbent, and the result the protection time of the sorbent increases due to the radiation regeneration of carbon. In present work the method was used for purification of effluents from pesticides, such as 4,4'Dichlorodiphenyltrichloroethane /DDT/, 1,2,3,4,5,6-hexachlorocyclohexane /HCCH/, dimethyl 2,2-dichlorovinylphosphate /DDVF/ and petroleum products (a mixture of kerosene and xylene in ratio 7:1). Such effluents are formed at factories producing an insecticide aerosol 'Prime-71'. Three investigations were carried out on model with a solution similar composition to industrial effluents. (author)

  12. Dynamic containment of gaseous effluents in the auxiliary buildings and reinjection of liquid effluents from these buildings back into the reactor building for 900 MWe PWRs under accident condition

    International Nuclear Information System (INIS)

    Demoulin, F.; Collinet, J.; Nguyen, C.

    1987-04-01

    Examination of the lessons to be learned from the accident of the Three Mile Island nuclear power plant on 20 March 1979 led the French Safety Authorities and EDF (Electricite de France) to adopt a series of measures intended to improve the performance of the containment of French PWRs, especially in the event of accident. Among the measures adopted, two of them contribute to the upgrading of the containment of nuclear island buildings, by reducing radioactivity constraints inside these buildings and by limiting radioactive releases into the environment. These are: (1) dynamic containment of auxiliary buildings likely to be contaminated following an accident, (2) reinjection back into the reactor building of liquid effluents arising in the auxiliary buildings. In this paper we shall discuss, for each measure, the approach to the problem and describe the arrangements made to arrive at a satisfactory solution [fr

  13. 40 CFR 421.73 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... produced Lead .000 .000 Zinc .000 .000 (d) Subpart G—Dross Reverberatory Slag Granulation. BAT Effluent... per billion pounds) of slag, speiss, or matte granulated Lead 1,612.000 748.400 Zinc 5,872.000 2,418... produced Lead .000 .000 Zinc .000 .000 (g) Subpart G—Hard Lead Refining Slag Granulation. BAT Effluent...

  14. Preparation of hydrophobic Pt-catalysts for decontamination of nuclear effluents

    International Nuclear Information System (INIS)

    Ionita, Gh.; Popescu, I.; Retegan, T.; Stefanescu, I.

    2005-01-01

    Based on the long experience of the authors, in the preparation, testing and evaluation of the performances of hydrophobic catalysts, and based on the reviewed references, this paper presents up-to-date R and D activities on the preparation methods and applications of the hydrophobic catalysts, in deuterium and tritium separation. The objectives of the paper are: (1) to provide a database for selection of the most appropriate catalyst and catalytic packing for above mentioned processes, (2) to evaluate the potentiality of hydrophobic Pt-catalysts in the deuterium and tritium separation (3) to asses and to find a new procedure for preparation a new improved hydrophobic catalyst. The merits of the hydrophobic catalysts are shown in comparison to hydrophilic catalysts. As results of the review some general conclusions about the applications of hydrophobic catalysts in environmental field are as follow: (1) the hydrophobic Pt-catalysts packed in the trickle bed reactors showed a high catalytic activity and long stability; (2) the utilization of the hydrophobic Pt-catalysts for tritium removal from liquid and gaseous effluent in nuclear field was entirely confirmed on industrial scale; (3) the extension of the utilization of the hydrophobic Pt-catalysts in other new processes, which take place in presence of liquid water or high humidity are subjected to testing. (author)

  15. Preparation of hydrophobic Pt-catalysts for decontamination of nuclear effluents

    International Nuclear Information System (INIS)

    Ionita, Gh.; Popescu, I.; Retegan, T.; Stefanescu, I.

    2004-01-01

    Based on the long experience of the authors, in the preparation, testing and evaluation of the performances of hydrophobic catalysts, and based on the reviewed references, this paper presents up-to-date R and D activities on the preparation methods and applications of the hydrophobic catalysts, in deuterium and tritium separation. The objectives of the paper are: - to provide a database for selection of the most appropriate catalyst and catalytic packing for above mentioned processes; - to evaluate the potentiality of hydrophobic Pt-catalysts in the deuterium and tritium separation; - to assess and to find a new procedure for preparation a new improved hydrophobic catalyst. The merits of the hydrophobic catalysts are shown in comparison to hydrophilic catalysts. As results of the review some general conclusions about the applications of hydrophobic catalysts in environmental field are as follows: - the hydrophobic Pt-catalysts packed in the trickle bed reactors showed a high catalytic activity and long stability; - the utilization of the hydrophobic Pt-catalysts for tritium removal from liquid and gaseous effluent in nuclear field was entirely confirmed on industrial scale; - the extension of the utilization of the hydrophobic Pt-catalysts in other new processes, which take place in presence of liquid water or high humidity are subject to testing. (authors)

  16. Uso de metodologias ativas na formação técnica do agente comunitário de saúde

    OpenAIRE

    Pedrosa,Ivanilda Lacerda; Lira,Gildeci Alves de; Oliveira,Bernadete de; Silva,Maria do Socorro Moura Lins; Santos,Maria Betânea dos; Silva,Eliete Alves da; Freire,Djacyr Magna Cabral

    2011-01-01

    O objetivo deste relato é sistematizar a experiência com metodologias ativas dentro da formação técnica do agente comunitário de saúde da Escola Técnica de Saúde da Universidade Federal da Paraíba. O curso está organizado em etapas, tendo sido concluída a primeira, cujo propósito foi o de contribuir para a construção da identidade dos agentes comunitários de saúde. A aplicação de metodologias ativas leva o discente a refletir sobre o seu processo de trabalho e a transformar a sua realidade, b...

  17. Dynamical instability of a charged gaseous cylinder

    Science.gov (United States)

    Sharif, M.; Mumtaz, Saadia

    2017-10-01

    In this paper, we discuss dynamical instability of a charged dissipative cylinder under radial oscillations. For this purpose, we follow the Eulerian and Lagrangian approaches to evaluate linearized perturbed equation of motion. We formulate perturbed pressure in terms of adiabatic index by applying the conservation of baryon numbers. A variational principle is established to determine characteristic frequencies of oscillation which define stability criteria for a gaseous cylinder. We compute the ranges of radii as well as adiabatic index for both charged and uncharged cases in Newtonian and post-Newtonian limits. We conclude that dynamical instability occurs in the presence of charge if the gaseous cylinder contracts to the radius R*.

  18. Radiological safety system based on real-time tritium-in-air monitoring indoors and in effluents

    International Nuclear Information System (INIS)

    Bidica, N.; Sofalca, N; Balteanu, O.; Srefan, I.

    2006-01-01

    Exposure to tritium is an important health hazard in any tritium processing facility so that implementing a real-time tritium monitoring system is necessary for its operation in safety conditions. The tritium processing facility operators need to be informed at any time about the in-air tritium concentration indoors or in the stack effluents, in order to detect immediately any leaks in tritium containments, or any releases inside the buildings or to the environment. This information is very important for adopting if necessary protection measures and correcting actions as quickly as possible. In this paper we describe an improved real-time tritium monitoring system designed for the Heavy Water Detritiation Pilot Plant of National Institute for Cryogenics and Isotopes Separation, Rm. Valcea, Romania. The design of the Radiological Safety System implemented for the ICIT Water Detritiation Pilot Plant is intended to provide the maximum safety level based on the ALARA concept. The main functions of tritium monitoring system are: - monitoring the working areas and gaseous effluents by determination of the tritium-in-air activity concentration; - local and remote data display; - assessing of environment dose equivalent rates and dose equivalents in the working environment (for personnel exposure control and work planning); - assessing the total tritium activity released to the environment through ventilation exhaust stack; - safety functions, i.e., local and remote, locking/unlocking personnel access, process shut-down in emergency conditions and start of the air cleaning systems. With all these features our tritium monitoring system is really a safety system adequate for personnel and environmental protection. (authors)

  19. 40 CFR 418.32 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... solution product: Effluent characteristics Effluent limitations (mg/l) Maximum for any 1 day Average of...) 0.61 0.33 Note: Metric units: Kilogram/1,000 kg of product; English units: Pound/1,000 lb of product....18 0.59 Organic nitrogen (as N) 1.48 0.80 Note: Metric units: Kilogram/1,000 kg of product; English...

  20. Quality Assurance Project Plan for Facility Effluent Monitoring Plan activities

    International Nuclear Information System (INIS)

    Nickels, J.M.

    1991-06-01

    This Quality Assurance Project Plan addresses the quality assurance requirements for the Facility Monitoring Plans of the overall site-wide environmental monitoring plan. This plan specifically applies to the sampling and analysis activities and continuous monitoring performed for all Facility Effluent Monitoring Plan activities conducted by Westinghouse Hanford Company. It is generic in approach and will be implemented in conjunction with the specific requirements of individual Facility Effluent Monitoring Plans. This document is intended to be a basic road map to the Facility Effluent Monitoring Plan documents (i.e., the guidance document for preparing Facility Effluent Monitoring Plans, Facility Effluent Monitoring Plan determinations, management plan, and Facility Effluent Monitoring Plans). The implementing procedures, plans, and instructions are appropriate for the control of effluent monitoring plans requiring compliance with US Department of Energy, US Environmental Protection Agency, state, and local requirements. This Quality Assurance Project Plan contains a matrix of organizational responsibilities, procedural resources from facility or site manuals used in the Facility Effluent Monitoring Plans, and a list of the analytes of interest and analytical methods for each facility preparing a Facility Effluent Monitoring Plan. 44 refs., 1 figs., 2 tabs

  1. Heavy-metal contamination of agricultural soils irrigated with industrial effluents

    International Nuclear Information System (INIS)

    Nabi, G.; Ashraf, M.; Aslam, M. R.

    2001-01-01

    Pakistan is facing a thread of degradation of water and land-resources by industrial effluents. To evaluated the suitability of these effluents as a source of irrigation for agriculture and the study their effects on soil chemical properties, experiments were conducted in the industrial area of Sheikhupura, where effluent from Paper and Board Mill (PBM), Leather Industry (LI) and Fertilizer Industry (FI) were being used for irrigation. At each site, two fields were selected, one irrigated with industrial effluents and the other with tube-well/canal water. The soil samples were collected and analyzed for pH, ECe, SAR and for heavy metals, such as Cu, Cd, Cr, Zn, Pb, Mn, Fe, Al and Ni. Soil receiving effluent from LI showed higher ECe and SAR values, as compared to the soils receiving other effluents. The concentration of Al was high in the soil irrigated with LI effluent. The Mn and Fe contents were higher in soils irrigated with PBM effluent. Effluent from LI is not fit for irrigation, since its recipient soil showed high concentration of Cr and also high sodicity values. Except Cr, the heavy metals were not of environmental concern. (author)

  2. Bioremediation of the textile waste effluent by Chlorella vulgaris

    OpenAIRE

    El-Kassas, Hala Yassin; Mohamed, Laila Abdelfattah

    2014-01-01

    The microalgae biomass production from textile waste effluent is a possible solution for the environmental impact generated by the effluent discharge into water sources. The potential application of Chlorella vulgaris for bioremediation of textile waste effluent (WE) was investigated using 22 Central Composite Design (CCD). This work addresses the adaptation of the microalgae C. vulgaris in textile waste effluent (WE) and the study of the best dilution of the WE for maximum biomass production...

  3. Legal provisions governing liquid effluents radiological monitoring

    International Nuclear Information System (INIS)

    Gans, I.; Ruehle, H.

    1985-01-01

    The KTA rule 1504 for radiological monitoring of liquid effluents from nuclear installations is explained. As there are no such rules published to date for establishments handling isotopes, some criteria are discussed which in the future ought to form part of a practical guide for liquid effluents monitoring in isotope handling installations. Monitoring measures described refer to liquid effluents from transfer containers, auxiliary cooling equipment, turbine buildings, main cooling installations, and waste air discharges from closed-circuit cooling systems. (DG) [de

  4. WASTE TREATMENT PLANT (WTP) LIQUID EFFLUENT TREATABILITY EVALUATION

    International Nuclear Information System (INIS)

    LUECK, K.J.

    2004-01-01

    A forecast of the radioactive, dangerous liquid effluents expected to be produced by the Waste Treatment Plant (WTP) was provided by Bechtel National, Inc. (BNI 2004). The forecast represents the liquid effluents generated from the processing of Tank Farm waste through the end-of-mission for the WTP. The WTP forecast is provided in the Appendices. The WTP liquid effluents will be stored, treated, and disposed of in the Liquid Effluent Retention Facility (LERF) and the Effluent Treatment Facility (ETF). Both facilities are located in the 200 East Area and are operated by Fluor Hanford, Inc. (FH) for the US. Department of Energy (DOE). The treatability of the WTP liquid effluents in the LERF/ETF was evaluated. The evaluation was conducted by comparing the forecast to the LERF/ETF treatability envelope (Aromi 1997), which provides information on the items which determine if a liquid effluent is acceptable for receipt and treatment at the LERF/ETF. The format of the evaluation corresponds directly to the outline of the treatability envelope document. Except where noted, the maximum annual average concentrations over the range of the 27 year forecast was evaluated against the treatability envelope. This is an acceptable approach because the volume capacity in the LERF Basin will equalize the minimum and maximum peaks. Background information on the LERF/ETF design basis is provided in the treatability envelope document

  5. Zero effluent; Efluente zero

    Energy Technology Data Exchange (ETDEWEB)

    Monteiro, Silvio Rogerio; Santos, Angelo Francisco dos [Liquigas Distribuidora S.A., Sao Paulo, SP (Brazil)

    2008-07-01

    A scenery of water shortage and the search for profitability improvement obligate the companies to exercise their creativity and to adopt alternative methods to the conventional ones to preserve the environmental resources. The 'Effluent Zero' project comes from a paradigms changing that the environmental preservation is a necessary cost. It brings a new analysis approach of this problem with the purpose to adapt the investments and operational costs with the effluents treatment to the demands of the productive processes. In Liquigas, the project brought significant results; made a potential reduction of nearly 90% in the investments of the effluents treatment systems. That means nearly 13% in reduction in the total investments in modernization and upgrade of the existents companies installations and of 1,6% in the total operational costs of the Company. Further more, it has contributed for a reduction of until 43% of the water consumption in the bottling process of the Liquefied Petroleum Gas (LPG). This way, the project resulted in effective actions of environmental protection with relevant economic benefits. (author)

  6. High-yield pulping effluent treatment technologies

    International Nuclear Information System (INIS)

    Su, W.X.; Hsieh, J.S.

    1993-03-01

    The objective of this report is to examine the high-yield (mechanical) pulp processes with respect to environmental issues affected by the discharge of their waste streams. Various statistics are given that support the view that high-yield pulping processes will have major growth in the US regions where pulp mills are located, and sites for projects in the development phase are indicated. Conventional and innovative effluent-treatment technologies applicable to these processes are reviewed. The different types of mechanical pulping or high-yield processes are explained, and the chemical additives are discussed. The important relationship between pulp yield and measure of BOD in the effluent is graphically presented. Effluent contaminants are identified, along with other important characteristics of the streams. Current and proposed environmental limitations specifically related to mechanical pulp production are reviewed. Conventional and innovative effluent-treatment technologies are discussed, along with their principle applications, uses, advantages, and disadvantages. Sludge management and disposal techniques become an intimate part of the treatment of waste streams. The conclusion is made that conventional technologies can successfully treat effluent streams under current waste-water discharge limitations, but these systems may not be adequate when stricter standards are imposed. At present, the most important issue in the treatment of pulp-mill waste is the management and disposal of the resultant sludge

  7. Use of hydrophobic Pt-catalysts in tritium removal from effluents

    International Nuclear Information System (INIS)

    Gheorghe, Ionita; Popescu, Irina; Stefanescu, Ioan; Steflea, Dumitru; Varlam, Carmen

    2002-01-01

    Based on the long experience of the authors, in the preparation, testing and evaluation of the performances of hydrophobic catalysts, and based on the reviewed references, this paper presents up-to-date R and D activities on the application of the hydrophobic catalysts in tritium removal from nuclear effluents. Tritium removal from the heavy water reactor and nuclear reprocessing plant, the cleanup of atmosphere and gaseous effluents by hydrogen-oxygen recombination, removal of oxygen dissolved in water are presented and discussed. Unlike the conventional hydrophilic catalysts, the hydrophobic catalysts keep a high catalytic activity and stability, even under the direct contact to liquid water or in presence of saturated humidity. A large diversity of catalyst types (over 100 catalysts) was prepared and tested in order to make them feasible for such processes. The objectives of the review are: - to provide a database for selection of the most appropriate catalyst and catalytic packing for above mentioned processes; - the designing and operation of reactor packed with hydrophobic catalysts; - to evaluate the potentiality of hydrophobic Pt-catalysts in the present and future applications. The most important results are the following: - the hydrophobic Pt-catalysts packed in the trickle bed or separated bed reactors, showed a high catalytic activity and long stability; - the utilization of the hydrophobic Pt-catalysts for the hydrogen isotopes (tritium and deuterium) separation and for hydrogen-oxygen recombination in nuclear field was entirely confirmed on industrial scale; - the improvement of the inner geometry of the reactors and of the composition of mixed catalytic packing as well as the evaluation of performances of separation processes constitute a major contribution of the authors; - the extension of the utilization of the hydrophobic Pt-catalysts in the oxidation of volatile organic compounds from wastewater; - the removal of dissolved oxygen, and deuterium

  8. Regulatory review of releases from HIFAR of radioactive airborne effluent

    International Nuclear Information System (INIS)

    Westall, D.J.; Macnab, D.I.

    1996-01-01

    Full text: The Nuclear Safety Bureau (NSB) was set up by legislation in 1992 as an independent Commonwealth corporate body reporting to the Minister for Health and Family Services. Its functions include monitoring and reviewing the safety of nuclear plant owned or operated by the Australian Nuclear Science and Technology Organisation (ANSTO). The NSB sets requirements for authorisation of the operation of the HIFAR research reactor, and may impose restrictions and conditions on its operation. The authorisation for the operation of HIFAR includes a requirement for arrangements for the treatment, safe storage and disposal of solid, liquid and gaseous radioactive wastes from the reactor. The objective is to establish conditions which would ensure that radiation exposure to plant personnel and the public from radioactive wastes are within acceptable limits and that releases are maintained as low as reasonably achievable. The NSB has developed expectations based on international best practice, against which to review HIFAR's arrangements for satisfying the requirement and achieving the objective. Arrangements for the release of airborne radioactive effluent from HIFAR were reviewed by the NSB as part of an overall review of the upgrade of safety documentation for HIFAR. The NSB's expectations for the review were drawn from the International Atomic Energy Agency (IAEA) Basic Safety Standards (Safety Series No 115-I) and the National Health and Medical Research Council (NHMRC) Recommendations for Limiting Exposure to Ionizing Radiation (1995). These expectations included a hierarchy of primary dose limits, stack discharge limits and reference levels for HIFAR aimed at ensuring that radiation doses to the public due to airborne effluent are less than the national dose limits and ANSTO's dose constraints, and are as low as reasonably achievable. An approach favoured by the operator is to work directly to a primary dose limit using an airborne dispersion computer program to

  9. Air pollution with gaseous emissions and methods for their removal

    International Nuclear Information System (INIS)

    Vassilev, Venceslav; Boycheva, Sylvia; Fidancevska, Emilija

    2009-01-01

    Information concerning gaseous pollutants generated in the atmosphere, as a result of fuel incineration processes in thermal power and industrial plants, was summarized. The main methods and technologies for flue gases purification from the most ecologically hazardous pollutants are comparatively discussed. Keywords: gaseous pollutants, aerosols, flue gas purification systems and technologies, air ecology control

  10. Metodologia ABC: implantação numa microempresa ABC methodology: implementation on a micro firm

    Directory of Open Access Journals (Sweden)

    Orlando Duran

    2000-08-01

    Full Text Available Este trabalho relata a implantação da metodologia de custos baseados em atividades numa microempresa do ramo metalúrgico. A proposta pretende demonstrar a viabilidade de aplicar esta técnica em empresas sem importar seu tamanho, só realizando algumas adaptações que garantam baixo investimento e curto espaço de tempo para obter os resultados. Na parte final do trabalho se realiza uma análise dos resultados obtidos verificando-se o potencial da informação gerada pela metodologia e seu uso como ferramenta de gestão.This paper presents an implementation of the activity based costing (ABC methodology in a small firm. The approach presented is intended to demonstrate the feasibility of applying the ABC methodology at any sized firm, only through few adaptations for ensuring low investments fees and speed in obtaining results and information from the system. Discussion about the results obtained during the implementation case are presented and the potential of using the information generated from the system as a managing tool is commented.

  11. Sulphate removal from industrial effluents through barium sulphate precipitation

    CSIR Research Space (South Africa)

    Swanepoel, H

    2011-11-01

    Full Text Available The pollution of South Africa’s water resources puts a strain on an already stressed natural resource. One of the main pollution sources is industrial effluents such as acid mine drainage (AMD) and other mining effluents. These effluents usually...

  12. Gaseous radioiodine transport in the air-forage-cow-milk system

    International Nuclear Information System (INIS)

    Black, S.C.; Douglas, R.L.; Barth, D.S.

    1976-04-01

    To study the transport of 131 I in the air-forage-cow milk system, a gaseous form of 131 I was released over a field of growing alfalfa which also contained some baled hay and dairy cows in pens. Some of the alfalfa was converted to hay and fed to cows, and some was used as green chop for other cows and goats. The results of this experiment suggest that the deposition velocity of gaseous iodine is much less than that for iodine bound to particulates; that cows ingesting hay secrete a higher percentage of 131 I in milk than cows ingesting green chop; that gaseous forms do not penetrate hay bales to any great extent; that the gaseous form is transferred to milk in a manner similar to particulate forms; that ingestion of contaminated forage results in 80 times as much 131 I transfer to milk as does inhalation exposure to the same cloud; and that goats transfer 131 I from forage to milk more efficiently than do dairy cows

  13. Facility Effluent Monitoring Plan for the uranium trioxide facility

    International Nuclear Information System (INIS)

    Lohrasbi, J.; Johnson, D.L.; De Lorenzo, D.S.

    1993-12-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438-01. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated at a minimum of every three years

  14. Control of Effluent Gases from Solid Waste Processing using Impregnated Carbon Nanotubes

    Science.gov (United States)

    Li, Jing; Fisher, John; Wignarajah, Kanapathipillai

    2005-01-01

    One of the major problems associated with solid waste processing technologies is effluent contaminants that are released in gaseous forms from the processes. This is a concern in both biological as well as physicochemical solid waste processing. Carbon dioxide (CO2), the major gas released, does not present a serious problem and there are currently in place a number of flight-qualified technologies for CO2 removal. However, a number of other gases, in particular NOx, SO2, NH3, and various hydrocarbons (e.g. CH4) do present health hazards to the crew members in space habitats. In the present configuration of solid waste processing in the International Space Station (ISS), some of these gases are removed by the Trace Contaminant Control System (TCCS), demands a major resupply. Reduction of the resupply can be effective by using catalyst impregnated carbon nanotubes. For example, NO decomposition to N2 and O2 is thermodynamically favored. Data showing decomposition of NO on metal impregnated carbon nanotubes is presented. Comparisons are made of the existing TCCS systems with the carbon nanotube based technology for removing NOx based on mass/energy penalties.

  15. The effect of gaseous ammonia on cobalt perrhenate

    International Nuclear Information System (INIS)

    Maslov, L.P.; Men'shikov, O.D.; Borisov, V.V.; Sorokin, S.I.; Krutovertsev, S.A.; Kharkevich, S.I.; Ivanova, O.M.

    1994-01-01

    The influence of humid air ammonia mixture on crystal pentahydrate of cobalt(2) perrhenate has been studied by the methods of PES, IR spectroscopy thermal analysis and electrophysical measurements. It is shown that with an increase in ammonia content in gaseous phase cobalt perrhenate successively transforms into diaquodiammine-, tetrammine- and μ-dioxo-bis-(tetrammine) derivatives of cobalt. Reversibility of dioxocomplex formation and a correlation between the change in electrophysical properties of crystal sample and change in ammonia content in gaseous phase are pointed out. 16 refs.; 4 figs.; 1 tab

  16. Facility effluent monitoring plan for the plutonium-uranium extraction facility

    International Nuclear Information System (INIS)

    Nickels, J.M.; Geiger, J.L.

    1992-11-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. A facility effluent monitoring plan determination was performed during Calendar Year 1991 and the evaluation requires the need for a facility effluent monitoring plan. This document is prepared using the specific guidelines identified. in. A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements

  17. Some considerations on the use of gamma spectrometry for Kr-85 determination at gaseous effluents in the nuclear industry and environmental samples

    International Nuclear Information System (INIS)

    Heras Iniquez, M.C.; Perez Garcia, M.M.; Travesi, A.

    1983-01-01

    The possibilities of using high resolution gamma ray spectrometry with GeLi semiconductor detector for measured the 0.514 KeV gamma radiation of Kr-B5 la explored, The detection limit of Kr-85 for a measuring time is 4.10 - 4 μCi with a counting time of 1000 minutes in a GeLi detector with a 20% efficiency relative to the INa (Tl). It is concluded that the use of gamma ray spectrometry for measuring the Kr-85 is not useful for environmental samples, but it can be used for the Kr-85 effluents control in Nuclear Stations. (Author) 26 refs

  18. Combination of biological treatment of waste air and liquid effluents in small and medium-sized businesses by using spherical carrier media in exchange with each other. Final report; Kombination der biologischen Behandlung von Abluft- und Abwasserreinigung in kleinen und mittleren Unternehmen durch die Verwendung von kugeligen Traegermaterialien im gegenseitigen Austausch. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Kunz, P.M.; Brunk, M.; Bentz, P.; Bach, K.; Marcos del Rio, O.; Stahl, B.; Wolf, C.

    2002-05-08

    A combined system for biological treatment of solvent-contaminated liquid and gaseous effluents was to be constructed. The system was to be mobile for demonstration purposes in industrial processes and was to serve for dimensioning of full-scale systems. The system works by a combined process via exchange of spherical carriers with a growth of micro-organisms. Two pilot systems of the Institut fuer Biologische Verfahrenstechnik, one for liquid and one for gaseous effluents, were combined for this purpose, ensuring exchange of carrier materials between the two units. (orig.) [German] Aufgabe im Rahmen dieses F+E-Vorhabens war es gewesen, eine kombinierte biologische Abluft- und Abwasserreinigungsanlage - speziell fuer loesungsmittelhaltige Abluft und Abwaesser - zu untersuchen. Dazu sollte eine Anlage aufgebaut werden, die auch als Demonstrations- und Versuchsanlage zu Industriebetrieben gebracht und dort zur Dimensionierung von full-scale-Anlage eingesetzt werden kann. Idee fuer dieses Vorhaben war gewesen, die Kombination beider Behandlungssysteme ueber den Austausch von mit Mikroorganismen bewachsenem Traegermaterial herzustellen. Am Institut fuer Biologische Verfahrenstechnik existierte bereits eine Pilotanlage fuer die biologische Abwasserreinigung mit kugeligem Traegermaterial (Vario-Bio-Reaktor) und eine Pilotanlage fuer die biologische Behandlung von Abluft nach dem Trickling-Filter-Prinzip mit ebenfalls kugeligem Traegermaterial. Diese beiden Anlagen sollten miteinander kombiniert und der Austausch des Traegermaterials hergestellt werden. (orig.)

  19. Bioremediation of the textile waste effluent by Chlorella vulgaris

    Directory of Open Access Journals (Sweden)

    Hala Yassin El-Kassas

    2014-01-01

    Full Text Available The microalgae biomass production from textile waste effluent is a possible solution for the environmental impact generated by the effluent discharge into water sources. The potential application of Chlorella vulgaris for bioremediation of textile waste effluent (WE was investigated using 22 Central Composite Design (CCD. This work addresses the adaptation of the microalgae C. vulgaris in textile waste effluent (WE and the study of the best dilution of the WE for maximum biomass production and for the removal of colour and Chemical Oxygen Demand (COD by this microalga. The cultivation of C. vulgaris, presented maximum cellular concentrations Cmax and maximum specific growth rates μmax in the wastewater concentration of 5.0% and 17.5%, respectively. The highest colour and COD removals occurred with 17.5% of textile waste effluent. The results of C. vulgaris culture in the textile waste effluent demonstrated the possibility of using this microalga for the colour and COD removal and for biomass production. There was a significant negative relationship between textile waste effluent concentration and Cmax at 0.05 level of significance. However, sodium bicarbonate concentration did not significantly influence the responses of Cmax and the removal of colour and COD.

  20. National Gas Survey. Synthesized gaseous hydrocarbon fuels

    Energy Technology Data Exchange (ETDEWEB)

    None

    1978-06-01

    The supply-Technical Advisory Task Force-Synthesized Gaseous Hydrocarbon Fuels considered coal, hydrocarbon liquids, oil shales, tar sands, and bioconvertible materials as potential feedstocks for gaseous fuels. Current status of process technology for each feedstock was reviewed, economic evaluations including sensitivity analysis were made, and constraints for establishment of a synthesized gaseous hydrocarbon fuels industry considered. Process technology is presently available to manufacture gaseous hydrocarbon fuels from each of the feedstocks. In 1975 there were eleven liquid feedstock SNG plants in the United States having a capacity of 1.1 billion SCFD. There can be no contribution of SNG before 1982 from plants using feedstocks other than liquids because there are no plants in operation or under construction as of 1977. Costs for SNG are higher than current regulated prices for U.S. natural gas. Because of large reserves, coal is a prime feedstock candidate although there are major constraints in the area of coal leases, mining and water permits, and others. Commercial technology is available and several new gasification processes are under development. Oil shale is also a feedstock in large supply and commercial process technology is available. There are siting and permit constraints, and water availability may limit the ultimate size of an oil shale processing industry. Under projected conditions, bioconvertible materials are not expected to support the production of large quantities of pipeline quality gas during the next decade. Production of low or medium Btu gas from municipal solid wastes can be expected to be developed in urban areas in conjunction with savings in disposal costs. In the economic evaluations presented, the most significant factor for liquid feedstock plants is the anticipated cost of feedstock and fuel. The economic viability of plants using other feedstocks is primarily dependent upon capital requirements.

  1. A EPT sob a metodologia da alternância: a experiência do IF Brasília - campus Planaltina

    Directory of Open Access Journals (Sweden)

    Guilherme Lins de Magalhães

    2017-04-01

    Full Text Available Este artigo buscou entender como acontece o diálogo social entre os atores do mundo do trabalho e a instituição escolar e, assim, investigou se os conhecimentos disseminados pela escola, através da metodologia da alternância, influenciaram a atuação dos assentados como agentes de desenvolvimento da região. A pesquisa se desenvolveu a partir de uma abordagem de natureza qualitativa com uma dimensão empírica pautada na busca de respostas. Todavia, o curso não obteve total sucesso na aplicação da metodologia da alternância, por problemas de gestão, e assim acabou demonstrando aspectos de um curso semipresencial.

  2. USO DE METODOLOGIAS ATIVAS DE APRENDIZAGEM PARA A EDUCAÇÃO NA SAÚDE: ANÁLISE DA PRODUÇÃO CIENTÍFICA

    Directory of Open Access Journals (Sweden)

    Cilene Maria Freitas

    Full Text Available Resumo O presente artigo tem como objetivo principal analisar a produção científica sobre o uso de metodologias ativas de aprendizagem na educação na saúde. Trata-se de uma revisão bibliográfica da literatura utilizando-se para seleção dos artigos a base de dados da Biblioteca Virtual em Saúde. A pesquisa ocorreu nos meses de setembro a novembro de 2012. Na busca selecionaram-se 15 artigos completos. Os resultados evidenciaram que o uso das metodologias ativas motiva o discente e o direciona para buscar informações no intuito de solucionar impasse e promover seu próprio desenvolvimento, fazendo com que ele perceba que a nova aprendizagem é um instrumento necessário e significativo para ampliar suas possibilidades e caminhos. Essas metodologias também têm contribuído para mudanças no modo de pensar e agir dos profissionais de saúde, os quais passaram a interagir em um espaço plural de interesses, potencialidades e capacidades.

  3. A Population Study of Gaseous Exoplanets

    Science.gov (United States)

    Tsiaras, A.; Waldmann, I. P.; Zingales, T.; Rocchetto, M.; Morello, G.; Damiano, M.; Karpouzas, K.; Tinetti, G.; McKemmish, L. K.; Tennyson, J.; Yurchenko, S. N.

    2018-04-01

    We present here the analysis of 30 gaseous extrasolar planets, with temperatures between 600 and 2400 K and radii between 0.35 and 1.9 R Jup. The quality of the HST/WFC3 spatially scanned data combined with our specialized analysis tools allow us to study the largest and most self-consistent sample of exoplanetary transmission spectra to date and examine the collective behavior of warm and hot gaseous planets rather than isolated case studies. We define a new metric, the Atmospheric Detectability Index (ADI) to evaluate the statistical significance of an atmospheric detection and find statistically significant atmospheres in around 16 planets out of the 30 analyzed. For most of the Jupiters in our sample, we find the detectability of their atmospheres to be dependent on the planetary radius but not on the planetary mass. This indicates that planetary gravity plays a secondary role in the state of gaseous planetary atmospheres. We detect the presence of water vapour in all of the statistically detectable atmospheres, and we cannot rule out its presence in the atmospheres of the others. In addition, TiO and/or VO signatures are detected with 4σ confidence in WASP-76 b, and they are most likely present in WASP-121 b. We find no correlation between expected signal-to-noise and atmospheric detectability for most targets. This has important implications for future large-scale surveys.

  4. Purifying hydrocarbons in the gaseous stage

    Energy Technology Data Exchange (ETDEWEB)

    1937-02-01

    Gaseous tar oils are subjected, at temperatures of 320 to 380/sup 0/C, to the action of a mixture of activated carbon mixed with powdered metal which removes the sulfur contamination from the substance to be purified.

  5. ANÁLISE DAS METODOLOGIAS DE PLANEJAMENTO E ORGANIZAÇÃO DO TURISMO SEGUNDO OS PRINCIPAIS AUTORES BRASILEIROS

    Directory of Open Access Journals (Sweden)

    Jaqueline dos Santos Silva

    2014-02-01

    Full Text Available Este artigo aborda o tema “planejamento turístico” expondo um estudo analítico sobre as metodologias de planejamento e organização do turismo, publicadas pelos principais autores brasileiros tendo a finalidade de expor seus pontos fortes, pontos fracos, oportunidades, ameaças, dissensões e similitudes. De abordagem qualitativa; utilizou-se a pesquisa bibliográfica e eletrônica; realizaram-se fichamentos de 6 (seis obras selecionadas que foram submetidas a análise SWOT. Assim, este estudo possibilitou a oferta de informações sobre tais metodologias para que estas possam ser utilizadas no planejamento do turismo adequando-se à realidade das destinações turísticas e na intenção de se ampliar o debate sobre a produção teórica acerca do assunto no cenário nacional.

  6. Aplicação de metodologias Lean ao fabrico de elevadores

    OpenAIRE

    Oliveira, Bruno Daniel Machado de

    2012-01-01

    Num mercado cada vez mais competitivo, torna-se fundamental para as empresas produzirem mais com menos recursos, aumentando a eficiência interna, através da otimização dos seus processos. Neste contexto aparece o Lean Manufacturing, metodologia que tem como objetivo criar valor para os stakeholders, através da eliminação de desperdício na cadeia de valor. Este projeto descreve a análise e a formulação de soluções do processo de produção de um Módulo de Serviço, produto que faz parte do sis...

  7. A risk-based approach to liquid effluent monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Hull, L.C.

    1995-10-01

    DOE Order 5400.1 identifies six objectives of a liquid effluent monitoring program. A strategy is proposed that meets these objective in one of two ways: (1) by showing that effluent concentrations are below concentration limits set by permits or are below concentrations that could cause environmental problems or (2) by showing that concentrations in effluent have not changed from a period when treatment processes were in control and there were no unplanned releases. The intensity of liquid effluent monitoring should be graded to the importance of the source being monitored. This can be accomplished by determining the risk posed by the source. A definition of risk is presented that defines risk in terms of the statistical probability of exceeding a release limit and the time available to recover from an exceedance of a release limit. Three examples are presented that show this approach to grading an effluent monitoring program can be implemented at the Idaho National Engineering Laboratory and will reduce monitoring requirements.

  8. Asymptomatic Effluent Protozoa Colonization in Peritoneal Dialysis Patients.

    Science.gov (United States)

    Simões-Silva, Liliana; Correia, Inês; Barbosa, Joana; Santos-Araujo, Carla; Sousa, Maria João; Pestana, Manuel; Soares-Silva, Isabel; Sampaio-Maia, Benedita

    Currently, chronic kidney disease (CKD) is a global health problem. Considering the impaired immunity of CKD patients, the relevance of infection in peritoneal dialysis (PD), and the increased prevalence of parasites in CKD patients, protozoa colonization was evaluated in PD effluent from CKD patients undergoing PD. Overnight PD effluent was obtained from 49 asymptomatic stable PD patients. Protozoa analysis was performed microscopically by searching cysts and trophozoites in direct wet mount of PD effluent and after staining smears. Protozoa were found in PD effluent of 10.2% of evaluated PD patients, namely Blastocystis hominis, in 2 patients, and Entamoeba sp., Giardia sp., and Endolimax nana in the other 3 patients, respectively. None of these patients presented clinical signs or symptoms of peritonitis at the time of protozoa screening. Our results demonstrate that PD effluent may be susceptible to asymptomatic protozoa colonization. The clinical impact of this finding should be further investigated. Copyright © 2016 International Society for Peritoneal Dialysis.

  9. A risk-based approach to liquid effluent monitoring

    International Nuclear Information System (INIS)

    Hull, L.C.

    1995-10-01

    DOE Order 5400.1 identifies six objectives of a liquid effluent monitoring program. A strategy is proposed that meets these objective in one of two ways: (1) by showing that effluent concentrations are below concentration limits set by permits or are below concentrations that could cause environmental problems or (2) by showing that concentrations in effluent have not changed from a period when treatment processes were in control and there were no unplanned releases. The intensity of liquid effluent monitoring should be graded to the importance of the source being monitored. This can be accomplished by determining the risk posed by the source. A definition of risk is presented that defines risk in terms of the statistical probability of exceeding a release limit and the time available to recover from an exceedance of a release limit. Three examples are presented that show this approach to grading an effluent monitoring program can be implemented at the Idaho National Engineering Laboratory and will reduce monitoring requirements

  10. Liquid Effluent Monitoring Information System (LEMIS) System Construction

    International Nuclear Information System (INIS)

    Adams, R.T.

    1994-01-01

    The liquid effluent sampling program is part of the effort to minimize adverse environmental impact during the cleanup operation at the Hanford Site. Of the 33 Phase I and Phase II liquid effluents, all streams actively discharged to the soil column will be sampled. The Liquid Effluent Monitoring Information System (LEMIS) is being developed as the organized information repository facility in support of the liquid effluent monitoring requirements of the Tri-Party Agreement. It is necessary to provide an automated repository into which the results from liquid effluent sampling will be placed. This repository must provide for effective retention, review, and retrieval of selected sample data by authorized persons and organizations. This System Construction document is the aggregation of the DMR P+ methodology project management deliverables. Together they represent a description of the project and its plan through four Releases, corresponding to the definition and prioritization of requirements defined by the user

  11. Facility Effluent Monitoring Plan for the Plutonium Finishing Plant

    International Nuclear Information System (INIS)

    FRAZIER, T.P.

    1999-01-01

    A facility effluent monitoring plan is required by the U. S. Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether these systems are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. To ensure the long-range integrity of the effluent monitoring systems, an update to this facility effluent monitoring plan is required whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document is reviewed annually even if there are no operational changes, and is updated, at a minimum, every 3 years

  12. Low energy consumption method for separating gaseous mixtures and in particular for medium purity oxygen production

    Science.gov (United States)

    Jujasz, Albert J.; Burkhart, James A.; Greenberg, Ralph

    1988-01-01

    A method for the separation of gaseous mixtures such as air and for producing medium purity oxygen, comprising compressing the gaseous mixture in a first compressor to about 3.9-4.1 atmospheres pressure, passing said compressed gaseous mixture in heat exchange relationship with sub-ambient temperature gaseous nitrogen, dividing the cooled, pressurized gaseous mixture into first and second streams, introducing the first stream into the high pressure chamber of a double rectification column, separating the gaseous mixture in the rectification column into a liquid oxygen-enriched stream and a gaseous nitrogen stream and supplying the gaseous nitrogen stream for cooling the compressed gaseous mixture, removing the liquid oxygen-enriched stream from the low pressure chamber of the rectification column and pumping the liquid, oxygen-enriched steam to a predetermined pressure, cooling the second stream, condensing the cooled second stream and evaporating the oxygen-enriched stream in an evaporator-condenser, delivering the condensed second stream to the high pressure chamber of the rectification column, and heating the oxygen-enriched stream and blending the oxygen-enriched stream with a compressed blend-air stream to the desired oxygen concentration.

  13. Radioactive emission data from Canadian nuclear generating stations 1986 to 1995

    International Nuclear Information System (INIS)

    1997-05-01

    All nuclear generating station (NGSs) release small quantities of radioactivity in a controlled manner into both the atmosphere (as gaseous effluents) and adjoining water bodies (as liquid effluents). The purpose of this document is to report on the magnitude of these emissions for each operating NGS in Canada and to indicate how these emissions compare with the relevant limitations imposed by the AECB as part of its regulatory and licensing program. The data show that the levels of emissions of gaseous and liquid effluents from all currently operating NGSs are well below the values mandated by the AECB. In fact, since 1987 no emissions have exceeded 1% of those values. 3 tabs., 46 figs

  14. Gaseous Electron Multiplier (GEM) Detectors

    Science.gov (United States)

    Gnanvo, Kondo

    2017-09-01

    Gaseous detectors have played a pivotal role as tracking devices in the field of particle physics experiments for the last fifty years. Recent advances in photolithography and micro processing techniques have enabled the transition from Multi Wire Proportional Chambers (MWPCs) and Drift Chambers to a new family of gaseous detectors refer to as Micro Pattern Gaseous Detectors (MPGDs). MPGDs combine the basic gas amplification principle with micro-structure printed circuits to provide detectors with excellent spatial and time resolution, high rate capability, low material budget and high radiation tolerance. Gas Electron Multiplier (GEMs) is a well-established MPGD technology invented by F. Sauli at CERN in 1997 and deployed various high energy physics (HEP) and nuclear NP experiment for tracking systems of current and future NP experiments. GEM detector combines an exceptional high rate capability (1 MHz / mm2) and robustness against harsh radiation environment with excellent position and timing resolution performances. Recent breakthroughs over the past decade have allowed the possibility for large area GEMs, making them cost effective and high-performance detector candidates to play pivotal role in current and future particle physics experiments. After a brief introduction of the basic principle of GEM technology, I will give a brief overview of the GEM detectors used in particle physics experiments over the past decades and especially in the NP community at Thomas Jefferson National Laboratory (JLab) and Brookhaven National Laboratory (BNL). I will follow by a review of state of the art of the new GEM development for the next generation of colliders such as Electron Ion Collider (EIC) or High Luminosity LHC and future Nuclear Physics experiments. I will conclude with a presentation of the CERN-based RD51 collaboration established in 2008 and its major achievements regarding technological developments and applications of MPGDs.

  15. Treatment of Plants with Gaseous Ethylene and Gaseous Inhibitors of Ethylene Action.

    Science.gov (United States)

    Tucker, Mark L; Kim, Joonyup; Wen, Chi-Kuang

    2017-01-01

    The gaseous nature of ethylene affects not only its role in plant biology but also how you treat plants with the hormone. In many ways, it simplifies the treatment problem. Other hormones have to be made up in solution and applied to some part of the plant hoping the hormone will be taken up into the plant and translocated throughout the plant at the desired concentration. Because all plant cells are connected by an intercellular gas space the ethylene concentration you treat with is relatively quickly reached throughout the plant. In some instances, like mature fruit, treatment with ethylene initiates autocatalytic synthesis of ethylene. However, in most experiments, the exogenous ethylene concentration is saturating, usually >1 μL L -1 , and the synthesis of additional ethylene is inconsequential. Also facilitating ethylene research compared with other hormones is that there are inhibitors of ethylene action 1-MCP (1-methylcyclopropene) and 2,5-NBD (2,5-norbornadiene) that are also gases wherein you can achieve nearly 100% inhibition of ethylene action quickly and with few side effects. Inhibitors for other plant hormones are applied as a solution and their transport and concentration at the desired site is not always known and difficult to measure. Here, our focus is on how to treat plants and plant parts with the ethylene gas and the gaseous inhibitors of ethylene action.

  16. Nitrification inhibitors mitigated reactive gaseous nitrogen intensity in intensive vegetable soils from China.

    Science.gov (United States)

    Fan, Changhua; Li, Bo; Xiong, Zhengqin

    2018-01-15

    Nitrification inhibitors, a promising tool for reducing nitrous oxide (N 2 O) losses and promoting nitrogen use efficiency by slowing nitrification, have gained extensive attention worldwide. However, there have been few attempts to explore the broad responses of multiple reactive gaseous nitrogen emissions of N 2 O, nitric oxide (NO) and ammonia (NH 3 ) and vegetable yield to nitrification inhibitor applications across intensive vegetable soils in China. A greenhouse pot experiment with five consecutive vegetable crops was performed to assess the efficacies of two nitrification inhibitors, namely, nitrapyrin and dicyandiamide on reactive gaseous nitrogen emissions, vegetable yield and reactive gaseous nitrogen intensity in four typical vegetable soils representing the intensive vegetable cropping systems across mainland China: an Acrisol from Hunan Province, an Anthrosol from Shanxi Province, a Cambisol from Shandong Province and a Phaeozem from Heilongjiang Province. The results showed soil type had significant influences on reactive gaseous nitrogen intensity, with reactive gaseous nitrogen emissions and yield mainly driven by soil factors: pH, nitrate, C:N ratio, cation exchange capacity and microbial biomass carbon. The highest reactive gaseous nitrogen emissions and reactive gaseous nitrogen intensity were in Acrisol while the highest vegetable yield occurred in Phaeozem. Nitrification inhibitor applications decreased N 2 O and NO emissions by 1.8-61.0% and 0.8-79.5%, respectively, but promoted NH 3 volatilization by 3.2-44.6% across all soils. Furthermore, significant positive correlations were observed between inhibited N 2 O+NO and stimulated NH 3 emissions with nitrification inhibitor additions across all soils, indicating that reduced nitrification posed the threat of NH 3 losses. Additionally, reactive gaseous nitrogen intensity was significantly reduced in the Anthrosol and Cambisol due to the reduced reactive gaseous nitrogen emissions and increased

  17. 324 and 327 Facilities Environmental Effluent Specifications

    International Nuclear Information System (INIS)

    JOHNSON, D.L.

    1999-01-01

    These effluent specifications address requirements for the 324/321 Facilities, which are undergoing stabilization activities. Effluent specifications are imposed to protect personnel, the environment and the public, by ensuring adequate implementation and compliance with federal and state regulatory requirements and Hanford programs

  18. Facility effluent monitoring plan for the tank farm facility

    Energy Technology Data Exchange (ETDEWEB)

    Crummel, G.M.

    1998-05-18

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements.

  19. Facility effluent monitoring plan for the fast flux test facility

    International Nuclear Information System (INIS)

    Nickels, J.M.; Dahl, N.R.

    1992-11-01

    A facility effluent monitoring plan is required by the US Department of Energy in US Department of Energy Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could affect employee or public safety or the environment. A Facility Effluent Monitoring Plan determination was performed during calendar year 1991 and the evaluation requires the need for a facility effluent monitoring plan. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements

  20. French studies on the thermal effluents of electric power plants

    International Nuclear Information System (INIS)

    Dezes-Cadiere, H.

    1976-01-01

    This report presents a synthesis of studies made in France in the thermal effluent field: thermal power plant cooling systems, transfer and dispersion of thermal effluents in the receptive media, effects of thermal effluents on water physicochemistry and biochemistry, effects of thermal effluents on aquatic ecosystems, and, possibilities of waste heat recovery with the view of utilization in agriculture, aquaculture and district heating. A catalogue of French organizations working or having data on thermal effluents is presented, as also an alphabetical list of the contacted persons. A bibliography of French documents concerning the previously mentioned studies is finally given (193 refs.) [fr

  1. Facility Effluent Monitoring Plan for the 222-S Laboratory

    International Nuclear Information System (INIS)

    Robinson, A.V.

    1991-11-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438. This facility effluent monitoring plan assesses effluent monitoring systems against applicable federal, state, and local requirements. This facility effluent monitoring plan is the first annual report. It shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. The current operation of the 222-S facilities includes the provision of analytical and radiological chemistry services in support of Hanford Site processing plants. The emphasis is on waste management, chemical processing, environmental monitoring effluent programs at B Plant, the Uranium Oxide Plant, Tank Farms, the 242-A Evaporator, the Waste Encapsulation and Storage Facility, the Plutonium-Uranium Extraction Facility, the Plutonium Finishing Plant, process development/impact activities, and essential materials. The laboratory also supplies analytical services in support of ongoing waste tank characterization

  2. Transmission environmental scanning electron microscope with scintillation gaseous detection device

    International Nuclear Information System (INIS)

    Danilatos, Gerasimos; Kollia, Mary; Dracopoulos, Vassileios

    2015-01-01

    A transmission environmental scanning electron microscope with use of a scintillation gaseous detection device has been implemented. This corresponds to a transmission scanning electron microscope but with addition of a gaseous environment acting both as environmental and detection medium. A commercial type of low vacuum machine has been employed together with appropriate modifications to the detection configuration. This involves controlled screening of various emitted signals in conjunction with a scintillation gaseous detection device already provided with the machine for regular surface imaging. Dark field and bright field imaging has been obtained along with other detection conditions. With a progressive series of modifications and tests, the theory and practice of a novel type of microscopy is briefly shown now ushering further significant improvements and developments in electron microscopy as a whole. - Highlights: • Novel scanning transmission electron microscopy (STEM) with an environmental scanning electron microscope (ESEM) called TESEM. • Use of the gaseous detection device (GDD) in scintillation mode that allows high resolution bright and dark field imaging in the TESEM. • Novel approach towards a unification of both vacuum and environmental conditions in both bulk/surface and transmission mode of electron microscopy

  3. An introduction to technetium in the gaseous diffusion cascades

    International Nuclear Information System (INIS)

    Simmons, D.W.

    1996-09-01

    The radioisotope technetium-99 ( 99 Tc) was introduced into the gaseous diffusion plants (GDP) as a contaminant in uranium that had been reprocessed from spent nuclear reactor fuel. 99 Tc is a product of the nuclear fission of uranium-235 ( 235 U). The significantly higher emitted radioactivity of 99 Tc generates concern in the enrichment complex and warrants increased attention (1) to the control of all site emissions, (2) to worker exposures and contamination control when process equipment requires disassembly and decontamination, and (3) to product purity when the enriched uranium hexafluoride (UF 6 ) product is marketed to the private sector. A total of 101,268 metric tons of RU (∼96% of the total) was fed at the Paducah Gaseous Diffusion Plant (PGDP) between FY1953 and FY1976. An additional 5600 metric tons of RU from the government reactors were fed at the Oak Ridge Gaseous Diffusion Plant (ORGDP), plus an approximate 500 tons of foreign reactor returns. Only a small amount of RU was fed directly at the Portsmouth Gaseous Diffusion Plant (PORTS). The slightly enriched PGDP product was then fed to either the ORGDP or PORTS cascades for final enrichment. Bailey estimated in 1988 that of the 606 kg of Tc received at PGDP from RU, 121 kg was subsequently re-fed to ORGDP and 85 kg re-fed to PORTS

  4. Required ozone doses for removing pharmaceuticals from wastewater effluents

    DEFF Research Database (Denmark)

    Antoniou, Maria; Hey, Gerly; Rodríguez Vega, Sergio

    2013-01-01

    of each investigated API (DDO3) was determined for each effluent by fitting a first order equation to the remaining concentration of API at each applied ozone dose. Ozone dose requirements were found to vary significantly between effluents depending on their matrix characteristics.The specific ozone dose...... was then normalized to the dissolved organic carbon (DOC) of each effluent. The DDO3/DOC ratios were comparable for each API between the effluents.15 of the 42 investigated APIs could be classified as easily degradable (DDO3/DOC≤0.7), while 19 were moderately degradable (0.71.4). Furthermore, we predict...... that a reasonable estimate of the ozone dose required to remove any of the investigated APIs may be attained by multiplying the experimental average DDO3/DOC obtained with the actual DOC of any effluent....

  5. Facility effluent monitoring plan for the tank farms facilities

    Energy Technology Data Exchange (ETDEWEB)

    Bachand, D.D.; Crummel, G.M.

    1995-05-01

    A facility effluent monitoring plan is required by the US Department of Energy for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using specific guidelines. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated as a minimum every three years.

  6. Stress corrosion in gaseous environment

    International Nuclear Information System (INIS)

    Miannay, Dominique.

    1980-06-01

    The combined influences of a stress and a gaseous environment on materials can lead to brittleness and to unexpected delayed failure by stress corrosion cracking, fatigue cracking and creep. The most important parameters affering the material, the environment, the chemical reaction and the stress are emphasized and experimental works are described. Some trends for further research are given [fr

  7. Performance of drippers in two filtering systems using sewage treatment effluent

    Directory of Open Access Journals (Sweden)

    Alexandre B. Dalri

    Full Text Available ABSTRACT The objective of this study was to evaluate the performance of three models of drippers using treated sewage effluent, pure and diluted, and two types of filters, screen and disc. The treated sewage effluent used in the experiment was collected from the city’s treatment plant. The experiment included 12 lateral lines with three types of emitters to apply pure (100% and diluted (50% effluent filtered by screen and disc filters. The combination of those factors set the treatments: T1 (50% effluent diluted in fresh water filtered by a screen filter; T2 (50% effluent diluted in fresh water filtered by a disc filter; T3 (pure effluent filtered by a screen filter; T4 (pure effluent filtered by a disc filter. The results showed that the flat type emitter is less sensitive to clogging, the disc filter is the most suitable to prevent clogging and the use of pure or diluted sewage effluent increases the drippers’ flow rate coefficient of variation.

  8. Bioremediation of petroleum refinery effluent by Planococcus ...

    African Journals Online (AJOL)

    In the present investigation, Planococcus halophilus was screened for hydrocarbon degradation and bioremediation of refinery effluent. The test organism, P. halophilus, showed the capability to utilize kerosene as carbon source in minimal medium. Biological treatment of the refinery effluent with P. halophilus reduced the ...

  9. Management of radioactive effluents from research Reactors and PHWRs

    International Nuclear Information System (INIS)

    Bodke, S.B.; Surender Kumar; Sinha, P.K.; Budhwar, R.K.; Raj, Kanwar

    2006-01-01

    Indian nuclear power programme is mainly based on pressurized heavy water reactors (PHWRs). In addition we have research reactors namely Apsara, CIRUS, Dhruva at Trombay. The operation and maintenance activities of these reactors generate radioactive liquid waste. These wastes require effective management so that the release of radioactivity to the environment is well within the authorized limits. India is self reliant in the design, erection, commissioning and operation of effluent management system for nuclear reactors. Segregation at source based on nature of effluents and radioactivity content is the first and foremost step in the over all management of liquid effluents. The effluents from the power reactors contain mainly activation products like 3 H. It also contains fission products like 137 Cs. Containment of these radionuclide along with 60 Co, 90 Sr, 131 I plays an important part in liquid waste management. Treatment processes for decontamination of these radionuclide include chemical treatment, ion exchange, evaporation etc. Effluents after treatment are monitored and discharged to the nearby water body after filtration and dilution. The concentrates from the processes are conditioned in cement matrix and disposed in Near Surface Disposal Facilities (NSDFs) co-located at each site. Some times large quantity of effluents with higher radioactivity concentration may get generated from the abnormal operation such as failure of heat exchangers. These effluents are handled on a campaign basis for which adequate storage capacity is provided. The treatment is given taking into consideration the required decontamination factor (DF), capacities of available treatment process, discharge limits and the availability of the dilution water. Similarly large quantities of effluents may get generated during fuel clad failure incident in reactors. In such situation, as in CIRUS large volume of effluent containing higher radioactivity are generated and are managed by delay

  10. Effluent Information System (EIS) / Onsite Discharge Information System (ODIS): 1986 executive summary

    International Nuclear Information System (INIS)

    Watanabe, T.

    1987-09-01

    Department of Energy (DOE) data base systems aid DOE-Headquarters and Field Offices in managing the radioactive air and liquid effluents from DOE facilities. Data on effluents released offsite are entered into effluent information system (EIS) and data on effluents discharged onsite and retained onsite are entered into Onsite Discharge Information System (ODIS). This document is a summary of information obtained from the CY 1986 effluent data received from all DOE and DOE contractor facilities and entered in the data bases. Data from previous years are also included. The summary consists of information for effluents released offsite, and information for effluents retained onsite

  11. The effluent problem in a plutonium production centre

    International Nuclear Information System (INIS)

    Galley, R.; Cantel, J.

    1960-01-01

    The first part of the report is devoted to generalities: the geographical situation of the Marcoule Centre, the sources of radio-active effluent, methods of treating this effluent. In the second part the authors gives a detailed description of the various installations in the Radio-active Effluent Treatment Station at the Marcoule Centre, and outline the conditions governing the rejection of treated effluent into the Rhone. A few lines are given to comparisons between the results obtained from the use of these installations up till may 1959 and the expected results published by the same authors at the Brussels Conference (1956). In conclusion the authors lay down some of the essential principles, applicable to the study of new installations. (author) [fr

  12. Migration from Gasoline to Gaseous Fuel for Small-scale Electricity Generation Systems

    Directory of Open Access Journals (Sweden)

    Sukandar Sukandar

    2013-03-01

    Full Text Available This paper describes a study that gives a consideration to change fuel source for electricity generator from gasoline to combustible gas. A gaseous fuel conversion technology is presented and its performance is compared with gasoline. In the experiment, two types of load were tested, resistive and resistive-inductive. By using both fuels mostly the power factor (Cos ? of resistive-inductive load variations were greater than 0.8, and they had slight difference on operational voltage. The drawback of using gaseous fuel is the frequency of the electricity might be up to 10 Hz deviated from the standard frequency (i.e. 50 Hz. In the lab scale experiment, the gasoline consumption increased proportionally with the load increase, while using gaseous fuel the consumption of gas equal for two different load value in the range of 50% maximum load, which is 100 gram per 15 minutes operation. Therefore, the use of gaseous generation system should have average power twice than the required load. The main advantage using gaseous fuel (liquefied petroleum gas or biogas compared to gasoline is a cleaner emitted gas after combustion.

  13. The Gaseous Phase as a Probe of the Astrophysical Solid Phase Chemistry

    Energy Technology Data Exchange (ETDEWEB)

    Abou Mrad, Ninette; Duvernay, Fabrice; Isnard, Robin; Chiavassa, Thierry; Danger, Grégoire, E-mail: gregoire.danger@univ-amu.fr [Aix-Marseille Université, PIIM UMR-CNRS 7345, F-13397 Marseille (France)

    2017-09-10

    In support of space missions and spectroscopic observations, laboratory experiments on ice analogs enable a better understanding of organic matter formation and evolution in astrophysical environments. Herein, we report the monitoring of the gaseous phase of processed astrophysical ice analogs to determine if the gaseous phase can elucidate the chemical mechanisms and dominant reaction pathways occurring in the solid ice subjected to vacuum ultra-violet (VUV) irradiation at low temperature and subsequently warmed. Simple (CH{sub 3}OH), binary (H{sub 2}O:CH{sub 3}OH, CH{sub 3}OH:NH{sub 3}), and ternary ice analogs (H{sub 2}O:CH{sub 3}OH:NH{sub 3}) were VUV-processed and warmed. The evolution of volatile organic compounds in the gaseous phase shows a direct link between their relative abundances in the gaseous phase, and the radical and thermal chemistries modifying the initial ice composition. The correlation between the gaseous and solid phases may play a crucial role in deciphering the organic composition of astrophysical objects. As an example, possible solid compositions of the comet Lovejoy are suggested using the abundances of organics in its comae.

  14. Electrocoagulation for the treatment of textile industry effluent--a review.

    Science.gov (United States)

    Khandegar, V; Saroha, Anil K

    2013-10-15

    Various techniques such as physical, chemical, biological, advanced oxidation and electrochemical are used for the treatment of industrial effluent. The commonly used conventional biological treatment processes are time consuming, need large operational area and are not effective for effluent containing toxic elements. Advanced oxidation techniques result in high treatment cost and are generally used to obtain high purity grade water. The chemical coagulation technique is slow and generates large amount of sludge. Electrocoagulation has recently attracted attention as a potential technique for treating industrial effluent due to its versatility and environmental compatibility. This technique uses direct current source between metal electrodes immersed in the effluent, which causes the dissolution of electrode plates into the effluent. The metal ions, at an appropriate pH, can form wide range of coagulated species and metal hydroxides that destabilize and aggregate particles or precipitate and adsorb the dissolved contaminants. Therefore, the objective of the present manuscript is to review the potential of electrocoagulation for the treatment of industrial effluents, mainly removal of dyes from textile effluent. © 2013 Elsevier Ltd. All rights reserved.

  15. The influence of agro-industrial effluents on River Nile pollution

    Directory of Open Access Journals (Sweden)

    Sayeda M. Ali

    2011-01-01

    Full Text Available The major agro-industrial effluents of sugarcane and starch industries pose a serious threat to surface waters. Their disposal in the River Nile around Cairo city transitionally affected the microbial load. In situ bacterial enrichment (50–180% was reported and gradually diminished downstream; the lateral not vertical effect of the effluent disposal was evident. Disposed effluents increased BOD and COD, and then progressively decreased downstream. Ammoniacal N was elevated, indicating active biological ammonification and in situ biodegradability of the effluents. In vitro, the nitrogen-fixing rhizobacteria Crysomonas luteola, Azospirillum spp., Azomonas spp. and K. pneumoniae successfully grew in batch cultures prepared from the crude effluents. This was supported by adequate growth parameters and organic matter decomposition. Therefore, such biodegradability of the tested agro-industrial effluents strongly recommends their use for microbial biomass necessary for the production of bio-preparates.

  16. Physiochemical Treatment of Textile Industry Effluents

    International Nuclear Information System (INIS)

    Latif, M. I.; Qazi, M. A.; Khan, H.; Ahmad, N.

    2015-01-01

    The study mainly focuses on the application of chemical Coagulants (Lime, Alum and Ferrous Sulfate) and Advanced Oxidation Processes (AOPs) (Ozone Treatment and Fenton Process, alone and in combination) to treat textile industry effluents, optimization of coagulation process for various Coagulants in terms of process conditions, including coagulant dose, pH and settling time. The results revealed that Alum was most effective. The efficiency of coagulation process was dose dependent and 400 mg/L dose of Alum alone showed maximum color removal of 47%, 57% and 54% of yellow, red and blue dyes, respectively in addition to the COD removal of 44%. The combined applications of Alum and Lime (300:75 mg/L) and Lime and Alum (300:75 mg/L) showed slightly better COD removal of 51%. However, color removal efficiency of all coagulants was at par. The Ozonation process appeared the most promising for the treatment of waste water and color/COD removal, the efficiency of which increased with increasing the treatment time at constant Ozone dose. For less polluted effluents, 97% color removal was obtained after 1 minute and after 15 minutes for highly polluted effluents; The COD removal efficiency of the process for less polluted effluents was around 89% after 5 minutes Ozonation and for highly polluted effluents 88% COD removal after 40 minutes. The performance of Fenton process was extremely low as compared to Ozonation process. Increase in pH, significantly decreased the color removal efficiency of the process. COD removal efficiency of Fenton process increased with an increase in settling time. (author)

  17. Metodologia ativa na engenharia: verificação da abp em uma disciplina de engenharia de produção e um modelo passo a passo

    Directory of Open Access Journals (Sweden)

    Thales Martins Ponciano

    2017-06-01

    Full Text Available Este artigo verifica a aplicação da metodologia Aprendizagem Baseada em Problema (ABP na disciplina de Sistemas de Desenvolvimento de Produto do curso de Engenharia de Produção de uma universidade pública brasileira. Por meio da caracterização da metodologia foi possível observar a aplicabilidade dessa ferramenta em um curso de Engenharia que envolve diversas áreas do conhecimento e concilia atividades teóricas e práticas. De modo geral, as metodologias ativas, como a ABP, podem estimular os alunos a desenvolverem habilidades, como organização, liderança e pensamento crítico, que ultrapassam o conteúdo programático das disciplinas. Sendo assim, foi proposto um modelo passo a passo para a aplicação da ABP.

  18. Wastewater effluent dispersal in Southern California Bays

    KAUST Repository

    Uchiyama, Yusuke; Idica, Eileen Y.; McWilliams, James C.; Stolzenbach, Keith D.

    2014-01-01

    The dispersal and dilution of urban wastewater effluents from offshore, subsurface outfalls is simulated with a comprehensive circulation model with downscaling in nested grid configurations for San Pedro and Santa Monica Bays in Southern California during Fall of 2006. The circulation is comprised of mean persistent currents, mesoscale and submesoscale eddies, and tides. Effluent volume inflow rates at Huntington Beach and Hyperion are specified, and both their present outfall locations and alternative nearshore diversion sites are assessed. The effluent tracer concentration fields are highly intermittent mainly due to eddy currents, and their probability distribution functions have long tails of high concentration. The dilution rate is controlled by submesoscale stirring and straining in tracer filaments. The dominant dispersal pattern is alongshore in both directions, approximately along isobaths, over distances of more than 10. km before dilution takes over. The current outfall locations mostly keep the effluent below the surface and away from the shore, as intended, but the nearshore diversions do not. © 2014 Elsevier Ltd.

  19. Wastewater effluent dispersal in Southern California Bays

    KAUST Repository

    Uchiyama, Yusuke

    2014-03-01

    The dispersal and dilution of urban wastewater effluents from offshore, subsurface outfalls is simulated with a comprehensive circulation model with downscaling in nested grid configurations for San Pedro and Santa Monica Bays in Southern California during Fall of 2006. The circulation is comprised of mean persistent currents, mesoscale and submesoscale eddies, and tides. Effluent volume inflow rates at Huntington Beach and Hyperion are specified, and both their present outfall locations and alternative nearshore diversion sites are assessed. The effluent tracer concentration fields are highly intermittent mainly due to eddy currents, and their probability distribution functions have long tails of high concentration. The dilution rate is controlled by submesoscale stirring and straining in tracer filaments. The dominant dispersal pattern is alongshore in both directions, approximately along isobaths, over distances of more than 10. km before dilution takes over. The current outfall locations mostly keep the effluent below the surface and away from the shore, as intended, but the nearshore diversions do not. © 2014 Elsevier Ltd.

  20. Complete physico-chemical treatment for coke plant effluents.

    Science.gov (United States)

    Ghose, M K

    2002-03-01

    Naturally found coal is converted to coke which is suitable for metallurgical industries. Large quantities of liquid effluents produced contain a large amount of suspended solids, high COD, BOD, phenols, ammonia and other toxic substances which are causing serious pollution problem in the receiving water to which they are discharged. There are a large number of coke plants in the vicinity of Jharia Coal Field (JCF). Characteristics of the effluents have been evaluated. The present effluent treatment systems were found to be inadequate. Physico-chemical treatment has been considered as a suitable option for the treatment of coke plant effluents. Ammonia removal by synthetic zeolite, activated carbon for the removal of bacteria, viruses, refractory organics, etc. were utilized and the results are discussed. A scheme has been proposed for the complete physico-chemical treatment, which can be suitably adopted for the recycling, reuse and safe disposal of the treated effluent. Various unit process and unit operations involved in the treatment system have been discussed. The process may be useful on industrial scale at various sites.

  1. MODELAGEM DE UM SISTEMA MULTIAGENTE DE APOIO À PBL UTILIZANDO A METODOLOGIA MAS-COMMONKADS+

    Directory of Open Access Journals (Sweden)

    Laysa Mabel de Oliveira Fontes

    2014-10-01

    Full Text Available A aprendizagem baseada em problema (Problem-Based Learning - PBL é um método no qual os estudantes aprendem através da resolução de um problema que, em geral, não possui uma solução trivial e uma única solução correta. A PBL destaca o trabalho em equipe como um dos principais requisitos para o sucesso do processo de aprendizagem, ou seja, a colaboração é essencial. No entanto, a implantação de um método de ensino com base na PBL não é uma tarefa trivial. Em Ambientes Virtuais de Aprendizagem (AVAs, a complexidade de implantação deste método é ainda maior, pois o facilitador nem sempre pode detectar possíveis problemas na colaboração, nem possui todas as informações necessárias para aplicar as técnicas de aprendizagem deste método. Desta forma, este artigo apresenta o processo de modelagem de um Sistema Multiagente (SMA de apoio à PBL. O SMA proposto foi modelado utilizando a metodologia MAS-CommonKADS+, que consiste em uma extensão da metodologia MAS-CommonKADS.

  2. METODOLOGIAS ATIVAS DE ENSINO/APRENDIZAGEM: DIFICULDADES DE DOCENTES DE UM CURSO DE ENFERMAGEM

    OpenAIRE

    Mesquita,Simone Karine da Costa; Meneses,Rejane Millions Viana; Ramos,Déborah Karollyne Ribeiro

    2016-01-01

    Resumo O estudo objetivou identificar as dificuldades vivenciadas pelos docentes na implementação de metodologias ativas no curso de graduação em enfermagem de uma instituição federal localizada no Rio Grande do Norte. Tratou-se de pesquisa exploratório-descritiva com enfoque qualitativo. As entrevistas semiestruturadas foram aplicadas a vinte sujeitos nos meses de agosto e setembro de 2011 e, posteriormente, analisadas seguindo pressupostos da análise de conteúdo. As principais adversidades ...

  3. Performance analysis in stepped solar still for effluent desalination

    Energy Technology Data Exchange (ETDEWEB)

    Velmurugan, V. [Department of Mechanical Engineering, Infant Jesus College of Engineering, Thoothukudi, Tamil Nadu 628 851 (India); Naveen Kumar, K.J.; Noorul Haq, T.; Srithar, K. [Department of Mechanical Engineering, Thiagarajar College of Engineering, Madurai, Tamil Nadu 625 015 (India)

    2009-09-15

    In this work, a stepped solar still and an effluent settling tank are fabricated and tested for desalinating the textile effluent. The effluent is purified in an effluent settling tank. In this tank, large and fine solid particles are settled and clarified. The settled effluents are used as raw water in the stepped solar still. For better performance, the stepped solar still consists of 50 trays with two different depths. First 25 trays with 10 mm height and the next 25 trays with 5 mm height are used. Fin, sponge, pebble and combination of the above are used for enhancing the productivity of the stepped solar still. A maximum increase in productivity of 98% occurs in stepped solar still when fin, sponge and pebbles are used in this basin. Theoretical analysis agrees well with experimental results. (author)

  4. Measurements of gaseous multiplication coefficient in pure isobutane

    International Nuclear Information System (INIS)

    Lima, Iara Batista de

    2010-01-01

    In this work it is presented measurements of gaseous multiplication coefficient (α) in pure isobutane obtained with a parallel plate chamber, protected against discharges by one electrode (anode) of high resistivity glass (ρ = 2 x 10 12 Ω.cm). The method applied was the Pulsed Townsend, where the primary ionization is produced through the incidence of a nitrogen laser beam onto a metallic electrode (cathode). The electric currents measured with the chamber operating in both ionization and avalanche regimes were used to calculate the gaseous multiplication coefficient by the solution of the Townsend equation for uniform electric fields. The validation of the technique was provided by the measurements of gaseous multiplication coefficient in pure nitrogen, a widely studied gas, which has well-established data in literature. The α coefficients in isobutane were measured as a function of the reduced electric field in the range of 139Td up to 208Td. The obtained values were compared with those simulated by Imonte software (version 4.5) and the only experimental results available in the literature, recently obtained in our group. This comparison showed that the results are concordant within the experimental errors. (author)

  5. 200 Area TEDF effluent sampling and analysis plan

    International Nuclear Information System (INIS)

    Alaconis, W.C.; Ballantyne, N.A.; Boom, R.J.

    1995-06-01

    This sampling analysis sets forth the effluent sampling requirements, analytical methods, statistical analyses, and reporting requirements to satisfy the State Waste Discharge Permit No. ST4502 for the Treated Effluent Disposal Facility. These requirements are listed below: Determine the variability in the effluent of all constituents for which enforcement limits, early warning values and monitoring requirements; demonstrate compliance with the permit; and verify that BAT/AKART (Best Available Technology/All know and Reasonable Treatment) source, treatment, and technology controls are being met

  6. Plant and soil modifications by continuous surface effluent application

    Energy Technology Data Exchange (ETDEWEB)

    Tedesco, M J; Levien, R [Rio Grande do Sul Univ., Porto Alegre, RS (Brazil). Dept. of Solos; Mohrdieck, F G; Rodrigues, N R [CORSAN-SITEL, Triunfo, RS (Brazil). Polo Petroquimico do Sul. Dept. de Operacao e Manutencao; Flores, A I.P.

    1994-12-31

    In order to study the effects on soil and plants of the liquid effluent generated by a the Integrated Liquid Effluent Treatment System of a large Brazilian petrochemical complex, a field study was conducted in four areas which received the effluent and compared to control sites. This work presents some results of this study. 12 refs., 1 fig., 3 tabs.

  7. Plant and soil modifications by continuous surface effluent application

    Energy Technology Data Exchange (ETDEWEB)

    Tedesco, M.J.; Levien, R. [Rio Grande do Sul Univ., Porto Alegre, RS (Brazil). Dept. of Solos; Mohrdieck, F.G.; Rodrigues, N.R. [CORSAN-SITEL, Triunfo, RS (Brazil). Polo Petroquimico do Sul. Dept. de Operacao e Manutencao; Flores, A.I.P.

    1993-12-31

    In order to study the effects on soil and plants of the liquid effluent generated by a the Integrated Liquid Effluent Treatment System of a large Brazilian petrochemical complex, a field study was conducted in four areas which received the effluent and compared to control sites. This work presents some results of this study. 12 refs., 1 fig., 3 tabs.

  8. Dielectrophoretic separation of gaseous isotopes

    International Nuclear Information System (INIS)

    McConnell, D.B.

    1975-01-01

    Gaseous isotopes are separated from a mixture in a vertically elongated chamber by subjecting the mixture to a nonuniform transverse electric field. Dielectrophoretic separation of the isotopes is effected, producing a transverse temperature gradient in the chamber, thereby enhancing the separation by convective countercurrent flow. In the example given, the process and apparatus are applied to the production of heavy water from steam

  9. In-Plant Corrosion Study of Steels in Distillery Effluent Treatment Plant

    Science.gov (United States)

    Ram, Chhotu; Sharma, Chhaya; Singh, A. K.

    2015-05-01

    The present study deals with corrosion and performance of steels observed in an effluent treatment plant (ETP) of a distillery. For this purpose, the metal coupons were exposed in primary (untreated effluent) and secondary tank (anaerobic treatment effluent) of the ETP. The extent of attack has been correlated with the composition of the effluent with the help of laboratory immersion and electrochemical tests. Untreated distillery effluent found to be more corrosive than the anaerobic-treated effluents and is assigned due to chloride, phosphate, calcium, nitrate, and nitrite ions, which enhances corrosivity at acidic pH. Mild steel showed highest uniform and localized corrosion followed by stainless steels 304L and 316L and lowest in case of duplex 2205.

  10. Facility effluent monitoring plan determinations for the 200 Area facilities

    International Nuclear Information System (INIS)

    Nickels, J.M.

    1991-11-01

    The following facility effluent monitoring plan determinations document the evaluations conducted for the Westinghouse Hanford Company 200 Area facilities (chemical processing, waste management, 222-S Laboratory, and laundry) on the Hanford Site in south central Washington State. These evaluations determined the need for facility effluent monitoring plans for the 200 Area facilities. The facility effluent monitoring plan determinations have been prepared in accordance with A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438 (WHC 1991). The Plutonium/Uranium Extraction Plant and UO 3 facility effluent monitoring plan determinations were prepared by Los Alamos Technical Associates, Richland, Washington. The Plutonium Finishing Plant, Transuranic Waste Storage and Assay Facility, T Plant, Tank Farms, Low Level Burial Grounds, and 222-S Laboratory determinations were prepared by Science Applications International Corporation of Richland, Washington. The B Plant Facility Effluent Monitoring Plan Determination was prepared by ERCE Environmental Services of Richland, Washington

  11. Facility effluent monitoring plan for the plutonium-uranium extraction facility

    International Nuclear Information System (INIS)

    Lohrasbi, J.; Johnson, D.L.; De Lorenzo, D.S.

    1993-12-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438-01. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated at a minimum of every three years

  12. Facility effluent monitoring plan for the plutonium uranium extraction facility

    Energy Technology Data Exchange (ETDEWEB)

    Wiegand, D.L.

    1994-09-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438-01. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated at a minimum of every three years.

  13. Facility effluent monitoring plan for the plutonium uranium extraction facility

    International Nuclear Information System (INIS)

    Wiegand, D.L.

    1994-09-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438-01. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated at a minimum of every three years

  14. Facility effluent monitoring plan for the Plutonium Uranium Extraction Facility

    International Nuclear Information System (INIS)

    Greager, E.M.

    1997-01-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438-01. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether these systems are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan will ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated, at a minimum, every 3 years

  15. Facility effluent monitoring plan for the plutonium-uranium extraction facility

    Energy Technology Data Exchange (ETDEWEB)

    Lohrasbi, J.; Johnson, D.L. [Westinghouse Hanford Co., Richland, WA (United States); De Lorenzo, D.S. [Los Alamos Technical Associates, NM (United States)

    1993-12-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438-01. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated at a minimum of every three years.

  16. Evaluation of the cytogenotoxicity of textile effluents using Allium cepa L.

    Directory of Open Access Journals (Sweden)

    Sandro Barbosa

    2011-08-01

    Full Text Available The cytotoxic and genotoxic potential of the raw (EB and treated (ET effluents of two textile mills located in south of Minas Gerais State that have their effluents treated at the same Effluent Treatment Plant was investigated using the Allium cepa test system. Cytotoxicity was evaluated by the root elongation and mitotic index (MI endpoints and the genotoxicity was assessed by de determination of chromosome aberrations (CA.The effluent samples were tested at the concentrations 0 (ultrapure water, 25, 50, 75, and 100 % (v/v. A Completely Randomized Design with four replicates of 30 seeds was used. The effluent samples in almost all tested concentrations promoted an increase in root elongation compared to the negative control and this effect was probably related to nutrients levels and organic matter in effluent samples. A lower MI at all concentrations of ET compared to EB. The highest MI was observed at 100% (v/v concentration of both effluents. The highest rates of CA occurred at concentrations 75% (v/v of EB and 100% (v/v of both effluents. The effluent samples showed no cytotoxic effect, but cell division occurred disorderly, leading to increase rate of AC, revealing a genetoxic effect. Improvements in the wastewater treatment are needed to reduce environmental impacts.

  17. Coal washery effluent treatment for material recovery and water reuse

    Energy Technology Data Exchange (ETDEWEB)

    Banerjee, N.N.; Chaudhuri, M.

    1980-10-01

    Th effluent from coal washeries consisting mainly of coal fines is normally discharged to inland surface waters and causes severe river pollution with substantial loss of good quality coking coal. The study reported in this paper was undertaken to characterize the effluents from several coal washeries and to evaluate the potential of using various coagulants and coagulant aids for clarification of the effluent with a view to recovery of the coal fines and reuse of the clarified effluent. It has been demonstrated that higher recovery of coal fines can be achieved by using coagulants like alum or ferric chloride with or without coagulant aids with an added advantage of reuse of the clarified effluent in the washery.

  18. Overexpression of antibiotic resistance genes in hospital effluents over time.

    Science.gov (United States)

    Rowe, Will P M; Baker-Austin, Craig; Verner-Jeffreys, David W; Ryan, Jim J; Micallef, Christianne; Maskell, Duncan J; Pearce, Gareth P

    2017-06-01

    Effluents contain a diverse abundance of antibiotic resistance genes that augment the resistome of receiving aquatic environments. However, uncertainty remains regarding their temporal persistence, transcription and response to anthropogenic factors, such as antibiotic usage. We present a spatiotemporal study within a river catchment (River Cam, UK) that aims to determine the contribution of antibiotic resistance gene-containing effluents originating from sites of varying antibiotic usage to the receiving environment. Gene abundance in effluents (municipal hospital and dairy farm) was compared against background samples of the receiving aquatic environment (i.e. the catchment source) to determine the resistome contribution of effluents. We used metagenomics and metatranscriptomics to correlate DNA and RNA abundance and identified differentially regulated gene transcripts. We found that mean antibiotic resistance gene and transcript abundances were correlated for both hospital ( ρ  = 0.9, two-tailed P  hospital effluent samples. High β-lactam resistance gene transcript abundance was related to hospital antibiotic usage over time and hospital effluents contained antibiotic residues. We conclude that effluents contribute high levels of antibiotic resistance genes to the aquatic environment; these genes are expressed at significant levels and are possibly related to the level of antibiotic usage at the effluent source. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy.

  19. Evaporation behaviour of different organic effluents from open surfaces.

    Science.gov (United States)

    Jhorar, B S; Malik, R S

    1993-01-01

    Production of large quantities of effluents from different industrial units and the problems of their disposal necessitated this evaporation study. The evaporation of water, sewage water, oil refinery effluent, papermill effluent and liquor distillery effluent was observed in glass beakers when placed (i) in an oven at 60 degrees C and (ii) in screen house for 30 days, by periodically weighing of the beakers. In other experiments, the effect of increasing the frequency of stirring on increasing the evaporation efficiency of the liquor distillery effluent (ELD) was examined in detail. All of the organic effluents except ELD had similar evaporation behaviours as water, but formation of a self-forming film caused the evaporation of ELD to be considerably lower. Resistance to evaporation caused by this film was found to be a decreasing function of the frequency of stirring. This study has a bearing on improving the efficiency of evaporation lagoons, and three stirrings in a day with a manually drawn stirrer in a full-scale lagoon are proposed as a practical and economically viable technique to save 44% of lagoon land in arid and semi-arid regions of the world.

  20. 200 Area Effluent Treatment Facility: Delisting petition

    International Nuclear Information System (INIS)

    1993-08-01

    Waste water has been generated for over 40 years as a result of operations conducted on the Hanford Site. This waste water previously was discharged to cribs, ponds, or ditches. An example of such waste water includes process condensate that might have been in contact with dangerous waste or mixed waste (containing both radioactive and dangerous components). This petition presents the treatment technologies that are designed into the 200 Area Effluent Treatment Facility to eliminate the dangerous characteristics of the waste and to delist the effluent in accordance with the requirements found in 40 Code of Federal Regulations 260.20 and 260.22. The purpose of this petition is to demonstrate that the 242-A Evaporator process condensate will be treated adequately so that the effluent from the 200 Area Effluent Treatment Facility will no longer require management as a regulated dangerous waste. This demonstration was performed by use of a surrogate (synthetic) waste, designed by the US Department of Energy, Richland Operations Office to include species that represent all organic and inorganic constituents (but not radionuclide species) expected to be found on the Hanford Site. Thus, the surrogate will encompass not only the expected 242-A Evaporator process condensate characteristics, but those of other potential 200 Area Effluent Treatment Facility waste streams and additional 40 CFR Appendix VIII constituents

  1. Sevoflurane improves gaseous exchange and exerts protective ...

    African Journals Online (AJOL)

    Sevoflurane improves gaseous exchange and exerts protective effects in ... Lung water content and cell count were estimated by standard protocols. ... It reversed LPS-induced oxidative stress, as demonstrated by increase in total antioxidant ...

  2. Handling effluent from nuclear thermal propulsion system ground tests

    International Nuclear Information System (INIS)

    Shipers, L.R.; Allen, G.C.

    1992-01-01

    A variety of approaches for handling effluent from nuclear thermal propulsion system ground tests in an environmentally acceptable manner are discussed. The functional requirements of effluent treatment are defined and concept options are presented within the framework of these requirements. System concepts differ primarily in the choice of fission-product retention and waste handling concepts. The concept options considered range from closed cycle (venting the exhaust to a closed volume or recirculating the hydrogen in a closed loop) to open cycle (real time processing and venting of the effluent). This paper reviews the different methods to handle effluent from nuclear thermal propulsion system ground tests

  3. Transmission environmental scanning electron microscope with scintillation gaseous detection device.

    Science.gov (United States)

    Danilatos, Gerasimos; Kollia, Mary; Dracopoulos, Vassileios

    2015-03-01

    A transmission environmental scanning electron microscope with use of a scintillation gaseous detection device has been implemented. This corresponds to a transmission scanning electron microscope but with addition of a gaseous environment acting both as environmental and detection medium. A commercial type of low vacuum machine has been employed together with appropriate modifications to the detection configuration. This involves controlled screening of various emitted signals in conjunction with a scintillation gaseous detection device already provided with the machine for regular surface imaging. Dark field and bright field imaging has been obtained along with other detection conditions. With a progressive series of modifications and tests, the theory and practice of a novel type of microscopy is briefly shown now ushering further significant improvements and developments in electron microscopy as a whole. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Basic processes and trends in gaseous detectors

    CERN Multimedia

    1999-01-01

    Almost a century after the invention of the proportional counter, a large research effort is still devoted to better understand the basic properties of gaseous detectors, and to improve their performances and reliability, particularly in view of use at the high radiation levels expected at LHC. In the first part of the lectures, after a brief introduction on underlying physical phenomena, I will review modern sophisticated computational tools, as well as some classic "back of the envelope" analytical methods, available today for estimating the general performances of gaseous detectors. In the second part, I will analyze in more detail problems specific to the use of detectors at high rates (space charge, discharges, aging), and describe the recent development of powerful and perhaps more reliable devices, particularly in the field of position-sensitive micro-pattern detectors.

  5. Metodologias ativas de ensino e aprendizagem: uma experiência com docentes da educação básica

    Directory of Open Access Journals (Sweden)

    Antônio Eustáquio Ferreira

    2017-07-01

    Full Text Available Relato com o objetivo de descrever a experiência de um curso de formação continuada de professores, cujo título é Metodologias Ativas de Ensino e Aprendizagem: uma experiência com docentes da educação básica, desenvolvido em parceria com a Universidade Federal da Grande Dourados, sob a coordenação e execução do autor. Os resultados evidenciaram que o contato dos docentes da educação básica com algumas técnicas das Metodologias Ativas de Ensino e Aprendizagem provocam reflexões sobre suas atitudes e o seus papeis diante de um cenário desafiador, cujos estudantes têm acesso a um número sem limites de informações. O modelo utilizado teve como estratégia de ensino-aprendizagem o próprio método das Metodologias Ativas, caracterizado por colocar o estudante em contato com as técnicas, visando um ensino efetivamente comprometido com a aquisição de competências, habilidades e conhecimentos de modo que eles, os estudantes ou cursistas no caso possam ser atores críticos, reflexivos, transformadores da realidade, dos problemas que se apresentam. Os cursistas professores puderam repensar sobre seus deveres éticos para com a sociedade, revisando suas práticas de ensino-aprendizagem e modelos de avaliações.

  6. Electron impact phenomena and the properties of gaseous ions

    CERN Document Server

    Field, F H; Massey, H S W; Brueckner, Keith A

    1970-01-01

    Electron Impact Phenomena and the Properties of Gaseous Ions, Revised Edition deals with data pertaining to electron impact and to molecular gaseous ionic phenomena. This book discusses electron impact phenomena in gases at low pressure that involve low-energy electrons, which result in ion formation. The text also describes the use of mass spectrometers in electron impact studies and the degree of accuracy obtained when measuring electron impact energies. This book also reviews relatively low speed electrons and the transitions that result in the ionization of the atomic system. This text the

  7. Rapid monitoring of gaseous fission products in BWRs using a portable spectrometer

    International Nuclear Information System (INIS)

    Yeh, Wei-Wen; Lee, Cheng-Jong; Chen, Chen-Yi; Chung, Chien

    1996-01-01

    Rapid, quantitative determination of gaseous radionuclides is the most difficult task in the field of environmental monitoring for radiation. Although the identification of each gaseous radionuclide is relatively straightforward using its decayed gamma ray as an index, the quantitative measurement is hampered by the time-consuming sample collection procedures, in particular for the radioactive noble gaseous fission products of krypton and xenon. In this work, a field gamma-ray spectrometer consisting of a high-purity germanium detector, portable multichannel anlayzer, and a notebook computer was used to conduct rapid scanning of radioactive krypton and xenon in the air around a nuclear facility

  8. Biofuels and Bioproducts from Wet and Gaseous Waste Streams: Challenges and Opportunities

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2017-01-09

    This report draws together activities related to wet and gaseous waste feedstocks into a single document. It enables an amplified focus on feedstocks in the relevant technology and potential markets category. Also, this report helps to inform and support ongoing wet and gaseous resource recovery activities in the Bioenergy Technologies Office (BETO) and in the broader federal space. Historically, the office has identified wet and gaseous waste feedstocks as potentially advantageous, but has not pursued them with a sustained focus. This document seeks to position these waste streams appropriately alongside more traditional feedstocks in BETO efforts.

  9. The development of gaseous detectors with solid photocathodes for low temperature applications

    CERN Document Server

    Periale, L.; Iacobaeus, C.; Francke, T.; Lund-Jensen, B.; Pavlopoulos, N.; Picchi, P.; Pietropaolo, F.

    2004-01-01

    There are several applications and fundamental research areas which require the detection of VUV light at cryogenic temperatures. For these applications we have developed and successfully tested special designs of gaseous detectors with solid photocathodes able to operate at low temperatures: sealed gaseous detectors with MgF2 windows and windowless detectors. We have experimentally demonstrated, that both primary and secondary (due to the avalanche multiplication inside liquids) scintillation lights could be recorded by photosensitive gaseous detectors. The results of this work may allow one to significantly improve the operation of some noble liquid gas TPCs.

  10. Facility effluent monitoring plan for the plutonium-uranium extraction facility

    International Nuclear Information System (INIS)

    Thompson, R.J.; Sontage, S.

    1991-11-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan is the first annual report. It shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated as a minimum every three years

  11. Review of microfluidic cell culture devices for the control of gaseous microenvironments in vitro

    Science.gov (United States)

    Wu, H.-M.; Lee, T.-A.; Ko, P.-L.; Chiang, H.-J.; Peng, C.-C.; Tung, Y.-C.

    2018-04-01

    Gaseous microenvironments play important roles in various biological activities in vivo. However, it is challenging to precisely control gaseous microenvironments in vitro for cell culture due to the high diffusivity nature of gases. In recent years, microfluidics has paved the way for the development of new types of cell culture devices capable of manipulating cellular microenvironments, and provides a powerful tool for in vitro cell studies. This paper reviews recent developments of microfluidic cell culture devices for the control of gaseous microenvironments, and discusses the advantages and limitations of current devices. We conclude with suggestions for the future development of microfluidic cell culture devices for the control of gaseous microenvironments.

  12. Prefiltration of gaseous effluents in plant dismantling

    International Nuclear Information System (INIS)

    Pilot, G.; Pourprix, M.

    1991-01-01

    The dismantling techniques and mainly the thermal cutting tools can create large amounts of airbone dust, possibly contaminated in the case of the cutting of radioactive materials. Among the secondary solid emissions, the aerosols constitute the most mobile part which can disseminate contamination in the cell where the cutting operation takes place and in the ventilation ducts up to the HEPA filters. An optimised prefiltration coupled with a captation device at the aerosol generating source allows to avoid the dissemination of the contamination, to increase the life of HEPA filters and thus to reduce the amount of solid wastes. The object in this work was to select one or several cleaning devices, selection that can be done from the knowledge of the physico-chemical characteristics of the gas and aerosols to deal with, the available cleaning devices and the implied facility

  13. Microscale diffusion analysis of gaseous radioactive effluents

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byung Woo; Chang, Kwang Phil; Jeong, Guy Soo; Lee, Kwang Hee; Choi, Yong Seok; An, Jin Young [Sungkyunkwan University, Seoul (Korea, Republic of)

    1997-07-01

    The state-of-the art review and relevant data bases have been made in this study. Microscale wind-field model has been made and applied to the site= of a target domestic plant - Younggwang units. Following researches have been made; - Review of modeling status in U.S.A., European countries, and Japan, those theoretical backgrounds, and experimental activities - Graphical display of topographical grid data in the surrounding with the Younggwang N.P.P. and basic investigation of the surrounding geography - Survey of site meteorological data of the Younggwang N.P.P.; precipitation distribution, yearly average wind direction and joint frequency, seasonal wind rose, distribution of seasonal sea and land breeze, joint frequency with respect to the atmospheric stability, mixing height - Presentation of a draft to update the existing Korea real-time dose assessment system, FADAS and to interface to the AWS(Automatic Weather System) of the Korea Meteorology Administration. - Establishment of nested-grid system with micro- and macro- scale cells around the Younggwang nuclear power plant -Consideration of solar radiation effect by using land-use map -Analysis of wind field in the region of 30 x 30 km n the Younggwang site (Author) 67 refs., 20 tabs., 28 figs.

  14. [Newly Designed Water Treatment Systems for Hospital Effluent].

    Science.gov (United States)

    Azuma, Takashi

    2018-01-01

     Pharmaceuticals are indispensable to contemporary life. Recently, the emerging problem of pharmaceutical-based pollution of river environments, including drinking water sources and lakes, has begun to receive significant attention worldwide. Because pharmaceuticals are designed to perform specific physiological functions in targeted regions of the human body, there is increasing concern regarding their toxic effects, even at low concentrations, on aquatic ecosystems and human health, via residues in drinking water. Pharmaceuticals are consistently employed in hospitals to treat disease; and Japan, one of the most advanced countries in medical treatment, ranks second worldwide in the quantity of pharmaceuticals employed. Therefore, the development of technologies that minimize or lessen the related environmental risks for clinical effluent is an important task as well as that for sewage treatment plants (STPs). However, there has been limited research on clinical effluent, and much remains to be elucidated. In light of this, we are investigating the occurrence of pharmaceuticals, and the development of water treatment systems for clinical effluent. This review discusses the current research on clinical effluent and the development of advanced water treatment systems targeted at hospital effluent, and explores strategies for future environmental risk assessment and risk management.

  15. Electrochemical Corrosion Investigations on Anaerobic Treated Distillery Effluent

    Science.gov (United States)

    Ram, Chhotu; Sharma, Chhaya; Singh, A. K.

    2014-09-01

    Present study is focused on the corrosivity of anaerobic treated distillery effluent and corrosion performance of mild steel and stainless steels. Accordingly, electrochemical polarization tests were performed in both treated distillery and synthetic effluents. Polarization tests were also performed in synthetic solutions and it was observed that Cl- and K+ increase whereas SO4 -, PO4 -, NO3 -, and NO2 - decrease the corrosivity of effluent at alkaline pH. Further, comparison in corrosivity of distillery and synthetic effluents shows the former to be less corrosive and this is assigned due to the presence of amino acids and melanoidins. Mild steel experienced to have the highest corrosion rate followed by stainless steels—304L and 316L and lowest in case of SAF 2205. Relative corrosion resistance of stainless steels is observed to depend upon Cr, Mo, and N content.

  16. Detoxification of kraft pulp ECF bleaching effluents by catalytic hydrotreatment.

    Science.gov (United States)

    Calvo, L; Gilarranz, M A; Casas, J A; Mohedano, A F; Rodríguez, J J

    2007-02-01

    Two different effluents from the D(1) and E(1) stages of the ECF bleaching of Eucalyptus globulus kraft pulp were treated by catalytic hydrogenation in a trickle bed reactor using commercial and homemade Pd/AC catalysts. The reactor was fed with the bleaching effluent and a H(2)/N(2) gas stream. The variables studied were space-time (1.4-5g(cat)min/mL), gas to liquid flow ratio (286-1000vol.), gas feed concentration (H(2):N(2), 1:1-1:7.3vol.), temperature (25-100 degrees C) and pressure (1-11bar). Hydrotreatment performance was evaluated in terms of ecotoxicity, adsorbable organic halogen (AOX), chemical oxygen demand (COD), biological oxygen demand (BOD(5)) and colour removal. In all the runs, the ecotoxicity of the effluents decreased as a result of the treatment, achieving reductions that ranged from 70% to 98%. Simultaneously to the reduction of toxicity, the hydrotreatment led to a decrease of the colour of the effluents, being the decrease significantly higher in the case of E(1) effluent. The AOX content was reduced by 85% and 23% for E(1) and D(1) effluents, respectively. In the case of D(1) effluent the removal of ecotoxicity was significantly higher than that of AOX, which indicates that much of the toxicity of the effluent must be associated to non-chlorinated organics. In spite of the important reduction of ecotoxicity, the biodegradability of the effluents only increased slightly. The homemade catalysts, prepared from activated carbons with a high external or non-microporous surface area and mesopore volume and a convenient surface chemistry showed a higher efficiency than the commercial one.

  17. Treated Effluent Disposal Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Treated non-hazardous and non-radioactive liquid wastes are collected and then disposed of through the systems at the Treated Effluent Disposal Facility (TEDF). More...

  18. Automated sampling and control of gaseous simulations

    KAUST Repository

    Huang, Ruoguan; Keyser, John

    2013-01-01

    In this work, we describe a method that automates the sampling and control of gaseous fluid simulations. Several recent approaches have provided techniques for artists to generate high-resolution simulations based on a low-resolution simulation

  19. Facility effluent monitoring plan for the 300 Area Fuels Fabrication Facility

    International Nuclear Information System (INIS)

    Nickels, J.M.; Brendel, D.F.

    1991-11-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP- 0438. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan is the first annual report. It shall ensure long-range integrity of the effluent monitoring system by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated as a minimum every three years. The Fuel Fabrication Facility in the Hanford 300 Area supported the production reactors from the 1940's until they were shut down in 1987. Prior to 1987 the Fuel Fabrication Facility released both airborne and liquid radioactive effluents. In January 1987 the emission of airborne radioactive effluents ceased with the shutdown of the fuels facility. The release of liquid radioactive effluents have continued although decreasing significantly from 1987 to 1990

  20. Electron beam gaseous pollutants treatment

    International Nuclear Information System (INIS)

    Chmielewski, A.G.

    1999-01-01

    Emission of gaseous pollutants, mostly during combustion of fossil fuels, creates a threat to the environment. New, economical technologies are needed for flue gas treatment. A physico-chemical basis of the process using electron beam for the simultaneous removal of sulfur and nitrogen oxides and volatile organic compounds are presented in this report. Development of the process and its upscaling has been discussed. (author)

  1. Utilization of vinasse effluents from an anaerobic reactor

    Energy Technology Data Exchange (ETDEWEB)

    Costa, F J.C.B.; Rocha, B B.M.; Viana, C E; Toledo, A C

    1986-01-01

    An anaerobic reactor was developed to biodigest alcohol distillery wastes. A further post-treatment of the effluent reduced the level of pollution to the point of eventually discharging into streams and rivers. The present work also analyses the use of biodigested vinasse as a source of food for fish. Very high efficiencies were obtained during primary and secondary treatment of vinasse effluent, as demonstrated by the greatly reduced organic load. The utilization of the treated effluent as a source of fish food presents an excellent alternative for the Brazilian alcohol industry. (Refs. 6).

  2. Diversity of marine invertebrates in a thermal effluent

    International Nuclear Information System (INIS)

    Logan, D.T.; Maurer, D.

    1975-01-01

    Invertebrates were collected at four sites in the Indian River and Indian River Bay in Delaware to study the effects of thermal effluents from a steam-generating plant. A list of species of anemones, nemerteans, annelids, molluscs, and crustaceans is presented. Differences in species composition, an increase in relative numbers of a pollution indicator organism, and reduction in species number and in the total number of organisms in the effluent were noted. The period of highest diversity corresponded to that of the lowest numbers of species and individuals and highest effluent temperatures. (U.S.)

  3. Radioactive effluent monitoring at the Idaho National Engineering Laboratory

    International Nuclear Information System (INIS)

    Simpson, O.D.

    1975-01-01

    The Effluent and Radiation Measurements Laboratory at the Idaho National Engineering Laboratory (INEL) has recently upgraded capabilities in the field of monitoring and analysis of radioactive airborne and liquid effluents using the techniques of gamma-ray spectrometry. The techniques and equipment used include remotely-operated, computer-based Ge(Li) spectrometers which obtain data on a real-time basis. Permanent record files are maintained of both the effluent release values and the gamma-ray data from which the release values are calculated. Should values for release levels ever be challenged, the gamma-ray spectral information for any measurement can be recalled and analyzed as needed. Daily effluent release reports are provided to operating personnel which contributes to prompt correction of any operational problems. Monthly, quarterly, and annual reports are compiled which provide inventories of the radionuclides released. A description of the effluent monitoring, reporting and records system developed at INEL for this application will be presented

  4. Pollution from tanneries effluents and its impact on environment

    International Nuclear Information System (INIS)

    Rajput, A.A.; Memon, Hafeez-ur-Rahman; Sahto, M.H.

    1999-01-01

    The disposal of tanneries effluence has become one of the serious environmental problems. The effluents from tanneries contain highly toxic materials, including chromium salts, ammonium salts, acids, sodium sulphide and suspended solids. Hair, alkalinity, surfactants, dyes and oils are also present in these effluents. The extent of pollution depends upon the volume of the effluent discharged. Many studies have been carried out on the characteristics of these effluents in order to understand the nature of the effluents and their impact on environment. The present study shows measured values of different parameters like Biochemical Oxygen Demand (BOD) about 1950 mg/l, Chemical Oxygen Demand (COD) about 4500-4600 mg/l, suspended solids about 2600-2700 mg/l, dissolved solids 10000-12000 mg/l and lead, copper, chromium and cadmium about 2, 0.4, 64.4 and 0.31 mg/l respectively. The measured values are compared with that of previous. Some remedial measures for its treatment and disposal are also discussed. (author)

  5. Utilização de metodologia ativa no ensino e assistência de enfermagem na produção nacional: revisão integrativa

    Directory of Open Access Journals (Sweden)

    Fernanda Ribeiro Sobral

    2012-02-01

    Full Text Available Esta é uma revisão integrativa de literatura cujo objetivo foi identificar e analisar publicações científicas sobre o uso das metodologias ativas no ensino e assistência de enfermagem no Brasil. O levantamento bibliográfico incluiu publicações nacionais, no período de 1999 a 2009. Foram verificadas as bases de dados LILACS, BDENF, MEDLINE e a biblioteca eletrônica SciELO. Foram selecionados 28 artigos. Os resultados e a análise mostraram a problematização como a principal metodologia ativa utilizada, a falta de referenciais teóricos para planejar a ação pedagógica e o uso excessivo de técnicas de ensino que nem sempre caracterizam a inovação do método. Conclui-se que a implementação das metodologias inovadoras ainda carece de mais estudos e necessita de maior investimento em pesquisa e divulgação sobre o assunto.

  6. The use of artificial wetlands to treat greenhouse effluents

    OpenAIRE

    Lévesque, Vicky; Dorais, Martine; Gravel, Valérie; Ménard, Claudine; Antoun, Hani; Rochette, Philippe; Roy, Stéphane

    2011-01-01

    Untreated greenhouse effluents or leak solution constitute a major environmental burden because their nitrate and phosphate concentrations may induce eutrophication. Artificial wetlands may offer a low cost alternative treatment of greenhouse effluents and consequently improve the sustainability of greenhouse growing systems. The objectives of this study were to 1) characterize the efficiency of different types of wetland to reduce ion content of greenhouse tomato effluent, and 2) improve the...

  7. Screening for crude oil degrading bacteria in liquid organic waste (effluent samples)

    International Nuclear Information System (INIS)

    Akpe, A.R.

    2014-01-01

    The screening for crude oil degrading bacteria in some liquid organic wastes (cassava mill effluents, rubber effluents and oil palm mill effluents) was carried out. Hydrocarbon utilising bacteria were isolated on mineral salt agar using vapour phase technique. The samples yielded 20 bacterial isolates from 13 different genera. Cassava mill effluent and rubber effluent had the highest number (7), while oil palm effluent had the least number (6) of bacterial isolates. The isolates that had the highest occurrence (occurring in all samples) were Pseudomonas aeruginosa and Escherichia coli. Of these 13 genera 9 were gram negative, while only 4 were gram positive. The total heterotrophic bacterial (THB) count and total hydrocarbon utilisers (THU) from all the effluent samples ranged from 3.0 * 10/sup 4/ to 6.0* 10/sup 7/ cfu/mL and 2.3 *10/sup 2/ to 4.2*10/sup 3/ cfu/mL, respectively. The counts of hydrocarbon utilisers were obviously lower than the heterotrophic counts, although the differences in counts were found to be statistically non-significant (P > 0.05). Rubber effluents and oil palm mill effluents had the highest number of hydrocarbon utilisers with three isolates each. The active hydrocarbon utilisers encountered in this study included Serratia marscescens, Bacillus cereus, P. aeruginosa, Enterobacter aerogenes and Bacillus subtilis. Presence of nutrients and crude oil degrading bacteria in these effluents suggests that these effluents can be used to enhance bioremediation through their use as biostimulation and bioaugmentation agents. (author)

  8. Paducah Gaseous Diffusion Plant environmental report for 1992

    Energy Technology Data Exchange (ETDEWEB)

    Horak, C.M. [ed.] [Martin Marietta Energy Systems, Inc., Oak Ridge, TN (United States)

    1993-09-01

    This two-part report, Paducah Gaseous Diffusion Plant Environmental Report for 1992, is published annually. It reflects the results of an environmental monitoring program designed to quantify potential increases in the concentration of contaminants and potential doses to the resident human population. The Paducah Gaseous Diffusion Plant (PGDP) overall goal for environmental management is to protect the environment and PGDP`s neighbors and to maintain full compliance with all current regulations. The current environmental strategy is to identify any deficiencies and to develop a system to resolve them. The long-range goal of environmental management is to minimize the source of pollutants, reduce the generation of waste, and minimize hazardous waste by substitution of materials.

  9. Paducah Gaseous Diffusion Plant environmental report for 1992

    International Nuclear Information System (INIS)

    Horak, C.M.

    1993-09-01

    This two-part report, Paducah Gaseous Diffusion Plant Environmental Report for 1992, is published annually. It reflects the results of an environmental monitoring program designed to quantify potential increases in the concentration of contaminants and potential doses to the resident human population. The Paducah Gaseous Diffusion Plant (PGDP) overall goal for environmental management is to protect the environment and PGDP's neighbors and to maintain full compliance with all current regulations. The current environmental strategy is to identify any deficiencies and to develop a system to resolve them. The long-range goal of environmental management is to minimize the source of pollutants, reduce the generation of waste, and minimize hazardous waste by substitution of materials

  10. Extruder system and method for treatment of a gaseous medium

    Energy Technology Data Exchange (ETDEWEB)

    Silvi, Norberto; Perry, Robert James; Singh, Surinder Prabhjot; Balch, Gary Stephen; Westendorf, Tiffany Elizabeth Pinard

    2016-04-05

    A system for treatment of a gaseous medium, comprises an extruder having a barrel. The extruder further comprises a first inlet port, a second inlet port, and a plurality of outlet ports coupled to the barrel. The first inlet port is configured for feeding a lean sorbent, the second inlet port is configured for feeding a gaseous medium, and the plurality of outlet ports are configured for releasing a plurality of components removed from the gaseous medium. Further, the extruder comprises a plurality of helical elements coupled to a plurality of kneading elements, mounted on a shaft, and disposed within the barrel. The barrel and the plurality of helical and kneading elements together form an absorption unit and a desorption unit. The first and second inlet ports are formed in the absorption unit and the plurality of outlet ports are formed in the absorption and desorption units.

  11. Characteristics and applications of small, portable gaseous air pollution monitors.

    Science.gov (United States)

    McKercher, Grant R; Salmond, Jennifer A; Vanos, Jennifer K

    2017-04-01

    Traditional approaches for measuring air quality based on fixed measurements are inadequate for personal exposure monitoring. To combat this issue, the use of small, portable gas-sensing air pollution monitoring technologies is increasing, with researchers and individuals employing portable and mobile methods to obtain more spatially and temporally representative air pollution data. However, many commercially available options are built for various applications and based on different technologies, assumptions, and limitations. A review of the monitor characteristics of small, gaseous monitors is missing from current scientific literature. A state-of-the-art review of small, portable monitors that measure ambient gaseous outdoor pollutants was developed to address broad trends during the last 5-10 years, and to help future experimenters interested in studying gaseous air pollutants choose monitors appropriate for their application and sampling needs. Trends in small, portable gaseous air pollution monitor uses and technologies were first identified and discussed in a review of literature. Next, searches of online databases were performed for articles containing specific information related to performance, characteristics, and use of such monitors that measure one or more of three criteria gaseous air pollutants: ozone, nitrogen dioxide, and carbon monoxide. All data were summarized into reference tables for comparison between applications, physical features, sensing capabilities, and costs of the devices. Recent portable monitoring trends are strongly related to associated applications and audiences. Fundamental research requires monitors with the best individual performance, and thus the highest cost technology. Monitor networking favors real-time capabilities and moderate cost for greater reproduction. Citizen science and crowdsourcing applications allow for lower-cost components; however important strengths and limitations for each application must be addressed

  12. Methanization of industrial liquid effluents

    International Nuclear Information System (INIS)

    Frederic, S.; Lugardon, A.

    2007-01-01

    In a first part, this work deals with the theoretical aspects of the methanization of the industrial effluents; the associated reactional processes are detailed. The second part presents the technological criteria for choosing the methanization process in terms of the characteristics of the effluent to be treated. Some of the methanization processes are presented with their respective advantages and disadvantages. At last, is described the implementation of an industrial methanization unit. The size and the main choices are detailed: the anaerobic reactor, the control, the valorization aspects of the biogas produced. Some examples of industrial developments illustrate the different used options. (O.M.)

  13. The application of XML in the effluents data modeling of nuclear facilities

    International Nuclear Information System (INIS)

    Yue Feng; Lin Quanyi; Yue Huiguo; Zhang Yan; Zhang Peng; Cao Jun; Chen Bo

    2013-01-01

    The radioactive effluent data, which can provide information to distinguish whether facilities, waste disposal, and control system run normally, is an important basis of safety regulation and emergency management. It can also provide the information to start emergency alarm system as soon as possible. XML technology is an effective tool to realize the standard of effluent data exchange, in favor of data collection, statistics and analysis, strengthening the effectiveness of effluent regulation. This paper first introduces the concept of XML, the choices of effluent data modeling method, and then emphasizes the process of effluent model, finally the model and application are shown, While there is deficiency about the application of XML in the effluents data modeling of nuclear facilities, it is a beneficial attempt to the informatization management of effluents. (authors)

  14. Petroleum Refinery Effluents Treatment by Advanced Oxidation Process with Methanol

    Energy Technology Data Exchange (ETDEWEB)

    Shoucheng, Wen [Yangtze Univ., HuBei Jingzhou (China)

    2014-02-15

    Petroleum refinery effluents are waste originating from industries primarily engaged in refining crude oil. It is a very complex compound of various oily wastes, water, heavy metals and so on. Conventional processes are unable to effectively remove the chemical oxygen demand (COD) of petroleum refinery effluents. Supercritical water oxidation (SCWO) was proposed to treat petroleum refinery effluents. In this paper, methanol was used to investigate co-oxidative effect of methanol on petroleum refinery effluents treatment. The results indicated that supercritical water oxidation is an effective process for petroleum refinery effluents treatment. Adding methanol caused an increase in COD removal. When reaction temperature is 440 .deg. C, residence time is 20 min, OE is 0.5 and initial COD is 40000 mg/L, and COD removal increases 8.5%.

  15. Petroleum Refinery Effluents Treatment by Advanced Oxidation Process with Methanol

    International Nuclear Information System (INIS)

    Shoucheng, Wen

    2014-01-01

    Petroleum refinery effluents are waste originating from industries primarily engaged in refining crude oil. It is a very complex compound of various oily wastes, water, heavy metals and so on. Conventional processes are unable to effectively remove the chemical oxygen demand (COD) of petroleum refinery effluents. Supercritical water oxidation (SCWO) was proposed to treat petroleum refinery effluents. In this paper, methanol was used to investigate co-oxidative effect of methanol on petroleum refinery effluents treatment. The results indicated that supercritical water oxidation is an effective process for petroleum refinery effluents treatment. Adding methanol caused an increase in COD removal. When reaction temperature is 440 .deg. C, residence time is 20 min, OE is 0.5 and initial COD is 40000 mg/L, and COD removal increases 8.5%

  16. Removing Gaseous NH3 Using Biochar as an Adsorbent

    Directory of Open Access Journals (Sweden)

    Kyoung S. Ro

    2015-09-01

    Full Text Available Ammonia is a major fugitive gas emitted from livestock operations and fertilization production. This study tested the potential of various biochars in removing gaseous ammonia via adsorption processes. Gaseous ammonia adsorption capacities of various biochars made from wood shaving and chicken litter with different thermal conditions and activation techniques were determined using laboratory adsorption column tests. Ammonia adsorption capacities of non-activated biochars ranged from 0.15 to 5.09 mg·N/g, which were comparable to that of other commercial activated carbon and natural zeolite. There were no significant differences in ammonia adsorption capacities of steam activated and non-activated biochars even if the surface areas of the steam activated biochars were about two orders of magnitude greater than that of non-activated biochars. In contrast, phosphoric acid activation greatly increased the biochar ammonia adsorption capacity. This suggests that the surface area of biochar did not readily control gaseous NH3 adsorption. Ammonia adsorption capacities were more or less linearly increased with acidic oxygen surface groups of non-activated and steam-activated biochars. Phosphoric acid bound to the acid activated biochars is suspected to contribute to the exceptionally high ammonia adsorption capacity. The sorption capacities of virgin and water-washed biochar samples were not different, suggesting the potential to regenerate spent biochar simply with water instead of energy- and capital-intensive steam. The results of this study suggest that non-activated biochars can successfully replace commercial activated carbon in removing gaseous ammonia and the removal efficiency will greatly increase if the biochars are activated with phosphoric acid.

  17. The Mass and Absorption Columns of Galactic Gaseous Halos

    Science.gov (United States)

    Qu, Zhijie; Bregman, Joel N.

    2018-01-01

    The gaseous halo surrounding the galaxy is a reservoir for the gas on the galaxy disk, supplying materials for the star formation. We developed a gaseous halo model connecting the galactic disk and the gaseous halo by assuming the star formation rate is equal to the radiative cooling rate. Besides the single-phase collisional gaseous halo, we also consider the photoionization effect and a time-independent cooling model that assumes the mass cooling rate is constant over all temperatures. The photoionization dominates the low mass galaxy and the outskirts of the massive galaxy due to the low-temperature or low-density nature. The multi-phase cooling model dominates the denser region within the cooling radius, where the efficient radiative cooling must be included. Applying these two improvements, our model can reproduce the most of observed high ionization state ions (i.e., O VI, O VII, Ne VIII and Mg X). Our models show that the O VI column density is almost a constant of around 10^14 cm^-2 over a wide stellar mass from M_\\star ~10^8 M_Sun to 10^11 M_Sun, which is constant with current observations. This model also implies the O VI is photoionized for the galaxy with a halo mass fraction function of the EAGLE simulation. Finally, our model predicts plateaus of the Ne VIII and the Mg X column densities above the sub-L^* galaxy, and the possibly detectable O VII and O VIII column densities for low-mass galaxies, which help to determine the required detection limit for the future observations and missions.

  18. Cyanobacterial flora from polluted industrial effluents.

    Science.gov (United States)

    Parikh, Amit; Shah, Vishal; Madamwar, Datta

    2006-05-01

    Effluents originating from pesticides, agro-chemicals, textile dyes and dyestuffs industries are always associated with high turbidity, colour, nutrient load, and heavy metals, toxic and persistent compounds. But even with such an anthropogenic nature, these effluents contain dynamic cyanobacterial communities. Documentation of cyanobacterial cultures along the water channels of effluents discharged by above mentioned industries along the west coast of India and their relationship with water quality is reported in this study. Intensity of pollution was evaluated by physico-chemical analysis of water. Higher load of solids, carbon and nutrients were found to be persistent throughout the analysis. Sediment and water samples were found to be colored in nature. Cyanobacterial community structure was found to be influenced by the anthropogenic pollution. 40 different cyanobacterial species were recorded from 14 genera of 5 families and an elevated occurrence of Phormidium, Oscillatoria and Chroococcus genera was observed in all the sampling sites.

  19. Metodologia para desenvolvimento de soluções em mineração de dados: Um estudo prático em diagnóstico de falhas

    OpenAIRE

    Carneiro Leão Vieira da Cunha, Rodrigo

    2005-01-01

    Data mining surgiu da necessidade de extração do conhecimento a partir de volumosas massas de dados. Na verdade data mining faz parte de um processo mais amplo e complexo denominado KDD (Knowledge Discovery in Databases). O problema é que não há na prática uma metodologia completa para apoiar o usuário no desenvolvimento do processo de KDD. Neste contexto, o principal objetivo do presente trabalho é propor uma metodologia genérica para desenvolvimento de soluções em KDD integra...

  20. Feasibility of using geothermal effluents for waterfowl wetlands

    Energy Technology Data Exchange (ETDEWEB)

    None

    1981-09-01

    This project was conducted to evaluate the feasibility of using geothermal effluents for developing and maintaining waterfowl wetlands. Information in the document pertains to a seven State area the West where geothermal resources have development potential. Information is included on physiochemical characteristics of geothermal effluents; known effects of constituents in the water on a wetland ecosystem and water quality criteria for maintaining a viable wetland; potential of sites for wetland development and disposal of effluent water from geothermal facilities; methods of disposal of effluents, including advantages of each method and associated costs; legal and institutional constraints which could affect geothermal wetland development; potential problems associated with depletion of geothermal resources and subsidence of wetland areas; potential interference (adverse and beneficial) of wetlands with ground water; special considerations for wetlands requirements including size, flows, and potential water usage; and final conclusions and recommendations for suitable sites for developing demonstration wetlands.

  1. Fast microbial reduction of ferrihydrite colloids from a soil effluent

    Science.gov (United States)

    Fritzsche, Andreas; Bosch, Julian; Rennert, Thilo; Heister, Katja; Braunschweig, Juliane; Meckenstock, Rainer U.; Totsche, Kai U.

    2012-01-01

    Recent studies on the microbial reduction of synthetic iron oxide colloids showed their superior electron accepting property in comparison to bulk iron oxides. However, natural colloidal iron oxides differ in composition from their synthetic counterparts. Besides a potential effect of colloid size, microbial iron reduction may be accelerated by electron-shuttling dissolved organic matter (DOM) as well as slowed down by inhibitors such as arsenic. We examined the microbial reduction of OM- and arsenic-containing ferrihydrite colloids. Four effluent fractions were collected from a soil column experiment run under water-saturated conditions. Ferrihydrite colloids precipitated from the soil effluent and exhibited stable hydrodynamic diameters ranging from 281 (±146) nm in the effluent fraction that was collected first and 100 (±43) nm in a subsequently obtained effluent fraction. Aliquots of these oxic effluent fractions were added to anoxic low salt medium containing diluted suspensions of Geobacter sulfurreducens. Independent of the initial colloid size, the soil effluent ferrihydrite colloids were quickly and completely reduced. The rates of Fe2+ formation ranged between 1.9 and 3.3 fmol h-1 cell-1, and are in the range of or slightly exceeding previously reported rates of synthetic ferrihydrite colloids (1.3 fmol h-1 cell-1), but greatly exceeding previously known rates of macroaggregate-ferrihydrite reduction (0.07 fmol h-1 cell-1). The inhibition of microbial Fe(III) reduction by arsenic is unlikely or overridden by the concurrent enhancement induced by soil effluent DOM. These organic species may have increased the already high intrinsic reducibility of colloidal ferrihydrite owing to quinone-mediated electron shuttling. Additionally, OM, which is structurally associated with the soil effluent ferrihydrite colloids, may also contribute to the higher reactivity due to increasing solubility and specific surface area of ferrihydrite. In conclusion, ferrihydrite

  2. Occurrence of disinfection byproducts in United States wastewater treatment plant effluents

    KAUST Repository

    Krasner, Stuart W.; Westerhoff, Paul K.; Chen, Baiyang; Rittmann, Bruce E.; Amy, Gary L.

    2009-01-01

    Effluents from wastewater treatment plants (WWTPs) contain disinfection byproducts (DBPs) of health concern when the water is utilized downstream as a potable water supply. The pattern of DBP formation was strongly affected by whether or not the WWTP achieved good nitrification. Chlorine addition to poorly nitrified effluents formed low levels of halogenated DBPs, except for (in some cases) dihalogenated acetic acids, but often substantial amounts of N-nitrosodimethyamine (NDMA). Chlorination of well-nitrified effluent typically resulted in substantial formation of halogenated DBPs but much less NDMA. For example, on a median basis after chlorine addition, the well-nitrified effluents had 57 μg/L of trihalomethanes [THMs] and 3 ng/L of NDMA, while the poorly nitrified effluents had 2 μg/L of THMs and 11 ng/L of NDMA. DBPs with amino acid precursors (haloacetonitriles, haloacetaldehydes) formed at substantial levels after chlorination of well-nitrified effluent. The formation of halogenated DBPs but not that of NDMA correlated with the formation of THMs in WWTP effluents disinfected with free chlorine. However, THM formation did not correlate with the formation of other DBPs in effluents disinfected with chloramines. Because of the relatively high levels of bromide in treated wastewater, bromine incorporation was observed in various classes of DBPs. © 2009 American Chemical Society.

  3. Occurrence of disinfection byproducts in United States wastewater treatment plant effluents

    KAUST Repository

    Krasner, Stuart W.

    2009-11-01

    Effluents from wastewater treatment plants (WWTPs) contain disinfection byproducts (DBPs) of health concern when the water is utilized downstream as a potable water supply. The pattern of DBP formation was strongly affected by whether or not the WWTP achieved good nitrification. Chlorine addition to poorly nitrified effluents formed low levels of halogenated DBPs, except for (in some cases) dihalogenated acetic acids, but often substantial amounts of N-nitrosodimethyamine (NDMA). Chlorination of well-nitrified effluent typically resulted in substantial formation of halogenated DBPs but much less NDMA. For example, on a median basis after chlorine addition, the well-nitrified effluents had 57 μg/L of trihalomethanes [THMs] and 3 ng/L of NDMA, while the poorly nitrified effluents had 2 μg/L of THMs and 11 ng/L of NDMA. DBPs with amino acid precursors (haloacetonitriles, haloacetaldehydes) formed at substantial levels after chlorination of well-nitrified effluent. The formation of halogenated DBPs but not that of NDMA correlated with the formation of THMs in WWTP effluents disinfected with free chlorine. However, THM formation did not correlate with the formation of other DBPs in effluents disinfected with chloramines. Because of the relatively high levels of bromide in treated wastewater, bromine incorporation was observed in various classes of DBPs. © 2009 American Chemical Society.

  4. Uso de metodologia participativa na obtenção de indicadores da qualidade do solo em Mossoró-RN

    Directory of Open Access Journals (Sweden)

    Luiz Eduardo Vieira de Arruda

    2013-03-01

    Full Text Available A metodologia participativa possibilita ao produtor rural de baixa renda a obtenção rápida e de forma confiável dos indicadores de qualidade do solo, auxiliando manter a sustentabilidade do agroecossistema. O presente trabalho tem por objetivo geral analisar a qualidade de solos preservados e degradados em Mossoró-RN utilizando metodologia participativa de baixo custo e fácil execução. Para tal, foram analisadas áreas degradas e preservadas do Parque Zoobotânico e Assentamento Mulunguzinho em Mossoró-RN. Foram escavadas trincheiras de 0,50 m x 0,50 m x 0,50 m de forma a visualizar a profundidade do horizonte A do solo de áreas degradas e preservadas. Um grupo com seis avaliadores aplicou a metodologia participativa com os seguintes indicadores: estrutura, compactação, erosão, microrganismos, matéria orgânica, organismos, retenção de água, cobertura e profundidade do horizonte A. Os indicadores foram obtidos da média de três repetições nas áreas degradas e preservadas, sendo posteriormente expressos em tabelas e gráficos tipo “teia”. De acordo com os resultados obtidos conclui-se que a metodologia participativa para avaliação da qualidade do solo é uma ferramenta de baixo custo e fácil aplicação que possibilita o fortalecimento do conhecimento do produtor rural e permite a troca de conhecimentos entre pesquisadores e agricultores; nas áreas degradadas avaliadas tanto do Parque Zoobotânico quanto no Assentamento Mulunguzinho os indicadores que mais penalizaram a média geral dos indicadores foram compactação e estrutura, indicando a necessidade de incorporação de matéria orgânica para atingir os limites aceitáveis de sustentabilidade em agroecossistemas; e os indicadores das áreas preservadas foram sempre superiores aos das áreas degradadas em maior presença de matéria orgânica que propicia melhoria da estrutura, compactação, biologia (macro e microrganismos e retenção de água no solo. Normal

  5. Liquid Effluent Retention Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Liquid Effluent Retention Facility (LERF) is located in the central part of the Hanford Site. LERF is permitted by the State of Washington and has three liquid...

  6. Facility effluent monitoring plan for K Area Spent Fuel. Revision 1

    International Nuclear Information System (INIS)

    Hunacek, G.S.

    1995-09-01

    The scope of this document includes program plans for monitoring and characterizing radioactive and nonradioactive hazardous materials discharged in the K Area effluents. This FEMP includes complete documentation for both airborne and liquid effluent monitoring systems that monitor radioactive and nonradioactive hazardous pollutants that could be discharged to the environment under routine and/or upset conditions. This documentation is provided for each K Area facility that uses, generates, releases, or manages significant quantities of radioactive and nonradioactive hazardous materials that could impact public and employee safety and the environment. This FEW describes the airborne and liquid effluent paths and the associated sampling and monitoring systems of the K Area facilities. Sufficient information is provided on the effluent characteristics and the effluent monitoring systems so that a compliance assessment against requirements may be performed. Adequate details are supplied such that radioactive and hazardous material source terms may be related to specific effluent streams which are, in turn, related to discharge points and finally compared to the effluent monitoring system capability

  7. Effects of effluent water on the abundance of cowpea insect pests.

    Science.gov (United States)

    Tiroesele, Bamphitlhi; Sitwane, Monametsi; Obopile, M; Ullah, Muhammad Irfan; Ali, Sajjad

    2017-10-03

    Botswana experiences low and unreliable rainfall. Thus, the use of effluent water in agriculture is increasingly important. Insect damage is the major constraint for cowpea grain production in the most cowpea-producing lands. We investigated the effects of effluent water on insect pest abundance on cowpea (Vigna unguiculata) under field conditions. The experiment was laid out in a randomized complete block design with 100, 75, 50, and 25% of effluent water and 0% (control-clean tap water) treatments. Treatments with 100% effluent water resulted in a significant increase in insect pest populations as compared with the control. These results show that the use of effluent water to irrigate crops may increase incidence, abundance, and damage caused by insect pests possibly by decreasing plant vigor. The use of effluent water in agriculture should be addressed in a wise way.

  8. Modos de produccion cientifica: Culturas y metodologias de investigacion en la Universidad de Cadiz

    Science.gov (United States)

    Gonzalez Ramos, Ana M.

    2004-12-01

    Este trabajo de investigacion supone un modelo teorico de caracter aplicado, que proporciona la oportunidad de evaluar la produccion cientifica de los investigadores. Se encuadra dentro de la tradiccion de la estadistica aplicada y la sociologia del conocimiento. Atiende especialmente a dos conjuntos de temas de interes, por una parte, las caracteristicas principales que determinan el nivel y tipo de produccion academica producida por las unidades de investigacion y por los propios investigadores; por otra, la utilizacion que se hace de los metodos y tecnicas de investigacion puesto que de ello tambien depende el modo de produccion cientifica. Los puntos novedosos de esta tesis son: la medicion cuantitativa del objeto de estudio, la suma de los productos y las condiciones externas a la produccion del conocimiento mas otros elementos internos como las caracteristicas de los investigadores y la metodologia utilizada para desarrollar sus trabajos; y, finalmente, el uso de las nuevas tecnologias. El aprovechamiento de los recursos estadisticos y las fuentes de informacion secundarias se complementan con el diseno propio de una encuesta donde se implementa las caracteristicas descritas en un capitulo anterior sobre los metodos cientificos mas idoneos descritos en los principales manuales y articulos cientificos desde distintas disciplinas de conocimiento. Dicha encuesta ha sido desarrollada como un programa propio y en base a los mas innovadores usos de la tecnologia en la metodologia de encuestas.

  9. Biochemical methane potential of kraft bleaching effluent and codigestion with other in-mill streams

    DEFF Research Database (Denmark)

    Fitamo, Temesgen Mathewos; Dahl, Olli; Master, Emma

    2016-01-01

    and in combination: total bleaching effluent, alkaline bleaching effluent, kraft evaporator condensate, and chemithermomechanical pulping effluent. The total bleaching effluent, consisting of the chlorine dioxide bleaching and alkaline bleaching effluents, exhibited the highest potential for organic matter...

  10. Chromium removal from tanning industries effluents

    International Nuclear Information System (INIS)

    Chaudry, M.A.; Ahmad, S.

    1997-01-01

    Air and water are the basic needs of human being and other living entities on the earth. Tanning industry uses water and some chemicals and so creates environmental problems, depending basically on two principal sources, hide and water. The processes of tanning are based on chromium sulphate and vegetable treatment of hide. According to the national environmental quality standards (NEQS) the effluent or disposed water should contain phenol less than 0.5 ppm, Cr, sulphates, chloride and other salts content. About 30-40 liters of water are used to process one Kg of raw hide into finished goods. Total installed capacity of hides and skins chrome tanning is 53.5 million square meter, earning a large amount of foreign exchange for our country. In the present work, seven tanning industries effluents from the suburbs of Multan city have been collected and analysed. The pH of the liquors have been found to vary from 2.72 to 4.4 and the constituent Cr have been found to be from zero to 8000 ppm from vegetable to chrome tanning industrial effluents studied. The stages involved in tanning and treatment of the effluent water waste including chemical treatment of Cr has been described with a special reference to supported liquid membranes process for removal of chromium ions. (author)

  11. Facility effluent monitoring plan for the 327 Facility

    International Nuclear Information System (INIS)

    1994-11-01

    The 327 Facility [Post-Irradiation Testing Laboratory] provides office and laboratory space for Pacific Northwest Laboratory (PNL) scientific and engineering staff conducting multidisciplinary research in the areas of post-irradiated fuels and structural materials. The facility is designed to accommodate the use of radioactive and hazardous materials in the conduct of these activities. This report summarizes the airborne emissions and liquid effluents and the results of the Facility Effluent Monitoring Plan (FEMP) determination for the facility. The complete monitoring plan includes characterization of effluent streams, monitoring/sampling design criteria, a description of the monitoring systems and sample analysis, and quality assurance requirements

  12. Guide for effluent radiological measurements at DOE installations

    International Nuclear Information System (INIS)

    Corley, J.P.; Corbit, C.D.

    1983-07-01

    Effluent monitoring and reporting programs are maintained at all US Department of Energy (DOE) facilities that may: (1) discharge significant concentrations of radioactivity in relation to applicable standards, or (2) discharge quantities of radioactivity that have potential health and safety or other environmental significance. This Guide is intended to provide supplemental guidance to DOE Orders on methods, procedures, and performance criteria to bring more comparable rationale to DOE facility effluent measurement programs and promote compliance with applicable standards and provide the DOE Office of Operational Safety (OOS) and Operations Offices with an additional tool for evaluating effluent measurement programs at DOE facilities

  13. A study of the annual doses to man from routine gaseous effluent releases of the Philippine Nuclear Power Plant Unit 1 (PNPP-1)

    International Nuclear Information System (INIS)

    Noriel, M.C.J.

    1983-01-01

    Individual and population integrated doses from radioactive gaseous releases of the Philippine Nuclear Power Plant 1 (PNPP-1) were calculated using a modified GASPAR Code. Input data consisted of meteorological and site data gathered from the PNPP-1 Final Analysis Report (FASR) population and agricultural data from the National Economic and Development Authority (NEDA) and the National Census and Statistics Office (NCSO). Usage factors were calculated based on Food and Nutrition Research Institute (FNRI) recommended dietary allowances for Filipinos. Results of population integrated dose calculations were used in identifying the critical nuclides, the critical body organs, and the critical pathway. Results from individual dose calculation were used in determining compliance with the dose limits set forth in Appendix D of Part 7 Code of Philippine Atomic Energy Commission (PAEC) regulations. (Author). 23 tabs.; 5 figs

  14. Global evaluation and calibration of a passive air sampler for gaseous mercury

    Science.gov (United States)

    McLagan, David S.; Mitchell, Carl P. J.; Steffen, Alexandra; Hung, Hayley; Shin, Cecilia; Stupple, Geoff W.; Olson, Mark L.; Luke, Winston T.; Kelley, Paul; Howard, Dean; Edwards, Grant C.; Nelson, Peter F.; Xiao, Hang; Sheu, Guey-Rong; Dreyer, Annekatrin; Huang, Haiyong; Hussain, Batual Abdul; Lei, Ying D.; Tavshunsky, Ilana; Wania, Frank

    2018-04-01

    Passive air samplers (PASs) for gaseous mercury (Hg) were deployed for time periods between 1 month and 1 year at 20 sites across the globe with continuous atmospheric Hg monitoring using active Tekran instruments. The purpose was to evaluate the accuracy of the PAS vis-à-vis the industry standard active instruments and to determine a sampling rate (SR; the volume of air stripped of gaseous Hg per unit of time) that is applicable across a wide range of conditions. The sites spanned a wide range of latitudes, altitudes, meteorological conditions, and gaseous Hg concentrations. Precision, based on 378 replicated deployments performed by numerous personnel at multiple sites, is 3.6 ± 3.0 %1, confirming the PAS's excellent reproducibility and ease of use. Using a SR previously determined at a single site, gaseous Hg concentrations derived from the globally distributed PASs deviate from Tekran-based concentrations by 14.2 ± 10 %. A recalibration using the entire new data set yields a slightly higher SR of 0.1354 ± 0.016 m3 day-1. When concentrations are derived from the PAS using this revised SR the difference between concentrations from active and passive sampling is reduced to 8.8 ± 7.5 %. At the mean gaseous Hg concentration across the study sites of 1.54 ng m-3, this represents an ability to resolve concentrations to within 0.13 ng m-3. Adjusting the sampling rate to deployment specific temperatures and wind speeds does not decrease the difference in active-passive concentration further (8.7 ± 5.7 %), but reduces its variability by leading to better agreement in Hg concentrations measured at sites with very high and very low temperatures and very high wind speeds. This value (8.7 ± 5.7 %) represents a conservative assessment of the overall uncertainty of the PAS due to inherent uncertainties of the Tekran instruments. Going forward, the recalibrated SR adjusted for temperature and wind speed should be used, especially if conditions are highly variable or

  15. Facility effluent monitoring plan determinations for the 400 Area facilities

    International Nuclear Information System (INIS)

    Nickels, J.M.

    1991-09-01

    This Facility Effluent Monitoring Plan determination resulted from an evaluation conducted for the Westinghouse Hanford Company 400 Area facilities on the Hanford Site. The Facility Effluent Monitoring Plan determinations have been prepared in accordance with A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans. Two major Westinghouse Hanford Company facilities in the 400 Area were evaluated: the Fast Flux Test Facility and the Fuels Manufacturing and examination Facility. The determinations were prepared by Westinghouse Hanford Company. Of these two facilities, only the Fast Flux Test Facility will require a Facility Effluent Monitoring Plan. 7 refs., 5 figs., 4 tabs

  16. Effluent Treatment Facility tritium emissions monitoring

    International Nuclear Information System (INIS)

    Dunn, D.L.

    1991-01-01

    An Environmental Protection Agency (EPA) approved sampling and analysis protocol was developed and executed to verify atmospheric emissions compliance for the new Savannah River Site (SRS) F/H area Effluent Treatment Facility. Sampling equipment was fabricated, installed, and tested at stack monitoring points for filtrable particulate radionuclides, radioactive iodine, and tritium. The only detectable anthropogenic radionuclides released from Effluent Treatment Facility stacks during monitoring were iodine-129 and tritium oxide. This paper only examines the collection and analysis of tritium oxide

  17. Facility effluent monitoring plan for the 2724-W Protective Equipment Decontamination Facility

    International Nuclear Information System (INIS)

    Nickels, J.M.; Lavey, G.H.

    1992-12-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1* for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. A facility effluent monitoring plan determination was performed during Calendar Year 1991 and the evaluation requires the need for a facility effluent monitoring plan. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438**. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements

  18. Calibration of new measuring systems to detect emissions of radioactive noble gases

    International Nuclear Information System (INIS)

    Winkelmann, I.; Kreiner, H.J.

    1977-12-01

    This report describes the calibration of different systems for the integral measurement of radioactive noble gases and the calibration of a measuring chamber for the detection of individual nuclides of radioactive noble gases in the gaseous effluent of nuclear power plants. For these measuring chambers the calibration factors for Kr-85 and Xe-133 are given as well as the detection limits to be obtained with these measuring systems for several radioactive noble gases present in the gaseous effluent at the stack of nuclear power plants. Calibration factors for Kr-85 and Xe-133 and the detection limits of this measuring method for the detections of individual nuclides of radioactive noble gases in air samples are defined taken wirh a high pressure compressor in pressure flasks an measured on a Ge(Li)-semiconductor spectrometer (pressure flask measuring method). A measuring equipment is described and calibrated which allows simultaneous measurement of activity concentration of radioactive noble gases and radioactive aerosols with a sensitivity of 2 x 10 -7 Ci/m 3 for radioactive gases and 1 x 10 -9 Ci/m 3 for radioactive particulates at a background radiation of 1 R/h. This paper is an additional report to our STH-Bericht 3/76, 'Calibration of measuring equipment for monitoring of gaseous effluents from nuclear power plants', which specifies a procedure for the calibration of measuring chambers for monitoring of gaseous radioactive effluents from nuclear power plants /1/. The calibration system used here makes it possible to simultaneously calibrate several noble gas measuring devices. (orig.) [de

  19. Charge Transfer Properties Through Graphene for Applications in Gaseous Detectors

    CERN Document Server

    Franchino, S.; Hall-Wilton, R.; Jackman, R.B.; Muller, H.; Nguyen, T.T.; de Oliveira, R.; Oliveri, E.; Pfeiffer, D.; Resnati, F.; Ropelewski, L.; Smith, J.; van Stenis, M.; Streli, C.; Thuiner, P.; Veenhof, R.

    2016-07-11

    Graphene is a single layer of carbon atoms arranged in a honeycomb lattice with remarkable mechanical and electrical properties. Regarded as the thinnest and narrowest conductive mesh, it has drastically different transmission behaviours when bombarded with electrons and ions in vacuum. This property, if confirmed in gas, may be a definitive solution for the ion back-flow problem in gaseous detectors. In order to ascertain this aspect, graphene layers of dimensions of about 2x2cm$^2$, grown on a copper substrate, are transferred onto a flat metal surface with holes, so that the graphene layer is freely suspended. The graphene and the support are installed into a gaseous detector equipped with a triple Gaseous Electron Multiplier (GEM), and the transparency properties to electrons and ions are studied in gas as a function of the electric fields. The techniques to produce the graphene samples are described, and we report on preliminary tests of graphene-coated GEMs.

  20. Effluent treatment efficiency and compliance monitoring in Nigerian ...

    African Journals Online (AJOL)

    The effectiveness of effluent treatment at the Eleme Petrochemical Industry, Port Harcourt, Nigeria was monitored weekly for six weeks to assess their level of compliance with the Directorate of Petroleum Resources (DPR) guidelines and standards for environmental safety. Effluent samples were taken from the untreated ...