WorldWideScience

Sample records for gas liquid chromatography

  1. Comparative determination of phenytoin by spectrophotometry, gas chromatography, liquid chromatography, enzyme immunoassay, and radioimmunoassay

    International Nuclear Information System (INIS)

    Castro, A.; Ibanez, J.; DiCesare, J.L.; Adams, R.F.; Malkus, H.

    1978-01-01

    Sera from patients being treated with phenytoin were analyzed for the drug by spectrophotometry, gas chromatography, radioimmunoasay, enzyme immunoassay, and liquid chromatography. The assay values obtained were intercompared statistically. Enzyme immunoassay and liquid chromatography appear to be attractive alternatives to the more traditional methods of spectrophotometry and gas chromatography. Our radioimmunoassay data correlated poorly with results by the four other methods

  2. Flow Rates in Liquid Chromatography, Gas Chromatography and Supercritical Fluid Chromatography: A Tool for Optimization

    Directory of Open Access Journals (Sweden)

    Joris Meurs

    2016-08-01

    Full Text Available This paper aimed to develop a standalone application for optimizing flow rates in liquid chromatography (LC, gas chromatography (GC and supercritical fluid chromatography (SFC. To do so, Van Deemter’s equation, Knox’ equation and Golay’s equation were implemented in a MATLAB script and subsequently a graphical user interface (GUI was created. The application will show the optimal flow rate or linear velocity and the corresponding plate height for the set input parameters. Furthermore, a plot will be shown in which the plate height is plotted against the linear flow velocity. Hence, this application will give optimized flow rates for any set conditions with minimal effort.

  3. 21 CFR 862.2250 - Gas liquid chromatography system for clinical use.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gas liquid chromatography system for clinical use... Instruments § 862.2250 Gas liquid chromatography system for clinical use. (a) Identification. A gas liquid chromatography system for clinical use is a device intended to separate one or more drugs or compounds from a...

  4. Detection of Griseofulvin and Dechlorogriseofulvin by Thin-Layer Chromatography and Gas-Liquid Chromatography

    Science.gov (United States)

    Cole, R. J.; Kirksey, J. W.; Holaday, C. E.

    1970-01-01

    A rapid and accurate method is described for the determination of griseofulvin and dechlorogriseofulvin extracted from Penicillium urticae with chloroform. Thinlayer chromatography was used to tentatively identify griseofulvin or dechlorogriseofulvin, or both. Two gas-liquid chromatographic systems provided additional qualitative information and simultaneous quantitation of the individual compounds. PMID:5415206

  5. Graphitized carbon in gas-liquid-solid chromatography and gas chromatography/mass spectrometric analysis of high boiling hydrocarbon mixtures

    International Nuclear Information System (INIS)

    Ciccioli, P.; Hayes, J.M.; Rinaldi, G.; Denson, K.B.; Meinschein, W.G.

    1979-01-01

    Gas--liquid--solid chromatography (GLSC) employing a poly(phenyl ether) (PPE 20) liquid phase on graphitized carbon black (GCB) is applicable to the analyses of crude oils and distillates of sedimentary rocks. The elution of C 4 to C 40 hydrocarbons which consist of n-alkanes, isoprenoid-type alkanes, steranes, olefins, and aromatic hydrocarbons can be handled in a single GC run. A GLSC column in tandem with a mass spectrometer provides an excellent means for the identification of geochemically significant organic compounds in complex natural mixtures. 8 figures, 4 tables

  6. (Vapour + liquid) equilibria of ternary systems with ionic liquids using headspace gas chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Mokhtarani, Babak [Chemistry and Chemical Engineering Research Center of Iran, P.O. Box 14335-186, Tehran (Iran, Islamic Republic of); Gmehling, Juergen, E-mail: gmehling@tech.chem.uni-oldenburg.d [Carl von Ossietzky Universitaet Oldenburg, Technische Chemie, D-26111 Oldenburg (Germany)

    2010-08-15

    (Vapour + liquid) equilibrium (VLE) data for the ternary systems (hexane + benzene), (hexane + cyclohexane), (benzene + cyclohexane), and (ethanol + water) with an ionic liquid as entrainer for extractive distillation were measured by headspace gas chromatography. As ionic liquids, 1-hexyl-3-methyl-imidazolium bis (trifluoromethyl-sulfonyl) imide [HMIM][BTI], 1-octyl-3-methyl-imidazolium bis (trifluoromethyl-sulfonyl) imide [OMIM][BTI], 1-octyl-3-methyl-imidazolium trifluoro-methanesulfonate [OMIM][OTF], and 1-butyl-3-methyl-imidazolium trifluoro-methanesulfonate [BMIM][OTF] were used. The experimental data show that the ionic liquids investigated have a great influence on the separation factors of the systems (hexane + benzene), (hexane + cyclohexane), and (benzene + cyclohexane). The experimental data were compared with the predicted results using mod. UNIFAC (Do). The predicted results are in good agreement with the experimental data.

  7. Comparison of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography for the separation of synthetic cathinones.

    Science.gov (United States)

    Carnes, Stephanie; O'Brien, Stacey; Szewczak, Angelica; Tremeau-Cayel, Lauriane; Rowe, Walter F; McCord, Bruce; Lurie, Ira S

    2017-09-01

    A comparison of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography for the separation of synthetic cathinones has been conducted. Nine different mixtures of bath salts were analyzed in this study. The three different chromatographic techniques were examined using a general set of controlled synthetic cathinones as well as a variety of other synthetic cathinones that exist as positional isomers. Overall 35 different synthetic cathinones were analyzed. A variety of column types and chromatographic modes were examined for developing each separation. For the ultra high performance supercritical fluid chromatography separations, analyses were performed using a series of Torus and Trefoil columns with either ammonium formate or ammonium hydroxide as additives, and methanol, ethanol or isopropanol organic solvents as modifiers. Ultra high performance liquid chromatographic separations were performed in both reversed phase and hydrophilic interaction chromatographic modes using SPP C18 and SPP HILIC columns. Gas chromatography separations were performed using an Elite-5MS capillary column. The orthogonality of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography was examined using principal component analysis. For the best overall separation of synthetic cathinones, the use of ultra high performance supercritical fluid chromatography in combination with gas chromatography is recommended. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Phytochemical Profile of Erythrina variegata by Using High-Performance Liquid Chromatography and Gas Chromatography-Mass Spectroscopy Analyses

    OpenAIRE

    Suriyavathana Muthukrishnan; Subha Palanisamy; Senthilkumar Subramanian; Sumathi Selvaraj; Kavitha Rani Mari; Ramalingam Kuppulingam

    2016-01-01

    Natural products derived from plant sources have been utilized to treat patients with numerous diseases. The phytochemical constituents present in ethanolic leaf extract of Erythrina variegata (ELEV) were identified by using high-performance liquid chromatography (HPLC) and gas chromatography-mass spectroscopy (GC-MS) analyses. Shade dried leaves were powdered and extracted with ethanol for analyses through HPLC to identify selected flavonoids and through GC-MS to identify other molecules. Th...

  9. Determination of Organic Pollutants in Small Samples of Groundwaters by Liquid-Liquid Extraction and Capillary Gas Chromatography

    DEFF Research Database (Denmark)

    Harrison, I.; Leader, R.U.; Higgo, J.J.W.

    1994-01-01

    A method is presented for the determination of 22 organic compounds in polluted groundwaters. The method includes liquid-liquid extraction of the base/neutral organics from small, alkaline groundwater samples, followed by derivatisation and liquid-liquid extraction of phenolic compounds after...... neutralisation. The extracts were analysed by capillary gas chromatography. Dual detection by flame Ionisation and electron capture was used to reduce analysis time....

  10. Gas Chromatography.

    Science.gov (United States)

    Cram, Stuart P.; And Others

    1980-01-01

    Selects fundamental developments in theory, methodology, and instrumentation in gas chromatography (GC). A special section reviews GC in the People's Republic of China. Over 1,000 references are cited. (CS)

  11. An analytical study by gas liquid chromatography and radiochromatography of tritium labelled lebaycid

    International Nuclear Information System (INIS)

    Perez Garcia, M. M.

    1969-01-01

    The stability and purity of the syntheses products of Lebaycid: 0,0 dime thylfosfochlorothionate and 4 methyl-thio-m-cresol were investigated by gas liquid chromatography. The study on (CH 3 O) 2 PSC1 was made in a column of Silicone SE-30, Reoplex 400 using a thermal conductivity detector. The 99,4% pure product obtained from the preparative gas chromatograph was found to be stable within the duration of the experiment: seven months. (Author) 23 refs

  12. Heterogeneous catalysis on solids of gases diffusing through a liquid layer, studied by inverse gas chromatography.

    Science.gov (United States)

    Kapolos, John; Katsanos, Nicholas A

    2002-11-15

    Physicochemical parameters for heterogeneous catalytic reactions when the catalytic bed was under a liquid phase have been determined, using a non-linear adsorption isotherm by the reversed-flow version of inverse gas chromatography (RF-GC). The mathematical analysis developed in heterogeneous catalysis, mass transfer across gas-liquid boundaries, and diffusion coefficients of gases in liquids was associated with a non-linear adsorption isotherm to find the relevant equations pertaining to the problem. These equations were then used to calculate the adsorption/desorption rate constant, the rate constant for the first-order catalytic reaction and the equilibrium constant for the non-linear adsorption isotherm. The diffusion coefficients of the reactant in the liquid and gaseous phases and the partition coefficients for the distribution of the reactant between the gaseous and liquid phase were also determined.

  13. Micromethod for measuring hexachlorophene in whole blood by gas-liquid chromatography.

    Science.gov (United States)

    Dodson, W E; Tyrala, E E; Hillman, R E

    1977-06-01

    We describe a micromethod for measuring hexachlorophene by use of gas-liquid chromatography with a 63Ni electron capture detector. The procedure requires 100 micronl of blood for extractions of hexachlorophene, and dichlorophene is added as an internal standard. CV is 3.4% over the concentration range of 500 to 1300 microng of hexachlorophene per liter of whole blood. This procedure permits repeated measurements of hexachlorophene in newborns who are being washed with soap containing hexachlorophene.

  14. Gas chromatography-mass spectrometry and high-performance liquid chromatographic analyses of thermal degradation products of common plastics.

    Science.gov (United States)

    Pacáková, V; Leclercq, P A

    1991-08-30

    The thermo-oxidation of five commonly used materials, namely low-density polyethylene, retarded polyethylene, paper with a polyethylene foil, a milk package and filled polypropylene, was studied. Capillary gas chromatography and gas chromatography-mass spectrometry were used to analyze the volatile degradation products, while high-performance liquid chromatography was employed to measure polycyclic aromatic hydrocarbons. The results are discussed from the point of view of toxicity of the products.

  15. Integrated gas and liquid chromatography tandem mass spectrometry for forensic engine lubricating oil identification

    International Nuclear Information System (INIS)

    Shang, D.; McPherson, B.

    2009-01-01

    This paper presented a method for rapid chemical characterization of engine lubricating oils. Motor oils typically contain up to 5 per cent additives, such as detergent, antifoamant, dispersant, emulsifier, antioxidant, friction modifier, colour stabilizer and corrosion inhibitors. Different lube oil products usually have either different additives in various concentrations. As such, the formulation of additives in lube oil products should provide fingerprint information for forensic oil identification. The characterization method used in this study was based on a newly developed fast solvent liquid-liquid sample extraction procedure that combined the use of both liquid chromatography tandem mass spectrometry (LC-MS) and gas chromatography-mass spectrometry (GC-MS) simultaneously together with gas chromatography flame ionization detection (GC-FID). The method was used on a blind sample testing of commercially available engine lubricating products. The sample extraction procedure involved extraction of additives into acidified acetonitrile, two hexane washes of hydrophobic components of lube oil, filtration, and dilution with solvents for GC and LC analysis. The new method proved to be rapid and easy to use. It enabled the identification of unknown additives and hydrocarbons in many different types of fresh lube oils. Further tests will be needed to determine if this method can be used on real-world weathered samples. The method is part of an ongoing effort to deal with mysterious chemical spills, an important aspect of environmental protection and emergency preparedness. 8 refs., 7 figs

  16. Experimental study on (vapor + liquid) equilibria of ternary systems of hydrocarbons/ionic liquid using headspace gas chromatography

    International Nuclear Information System (INIS)

    Mokhtarani, Babak; Valialahi, Leila; Heidar, Kurosh Tabar; Mortaheb, Hamid Reza; Sharifi, Ali; Mirzaei, Mojtaba

    2012-01-01

    Highlights: ► The ionic liquid [Omim][SCN] is considered as an appropriate entrainer for separation of five binary hydrocarbon systems. ► VLE data for the ternary systems consisting [Omim][SCN] and hydrocarbons were measured using headspace gas chromatography. ► The experimental VLE data are correlated using the thermodynamic model of NRTL with a good accuracy. ► The experimental results are compared with the VLE data using other ionic liquids as the entrainer. ► [Omim][SCN] can significantly improve the separation factors of these systems. - Abstract: (Vapor + liquid) equilibrium (VLE) data for ternary systems of (hexane + benzene), (hexane + cyclohexane), (benzene + cyclohexane), (1-hexene + cyclohexane), and (1-hexene + benzene) with an ionic liquid were measured by headspace gas chromatography. The applied ionic liquid 1-methyl 3-octylimidazolium thiocyanate, [Omim][SCN], acts as an entrainer. The comparison of the measured VLE data with the equilibrium data for the binary mixtures without ionic liquid show that [Omim][SCN] significantly improves the separation factor of these systems. The NRTL thermodynamic model is applied for correlating the experimental data. The modeling results show the NRTL model can correlate the experimental data with a good accuracy.

  17. High-pressure liquid chromatography with direct injection of gas sample.

    Science.gov (United States)

    Astanin, Anton I; Baram, Grigory I

    2017-06-09

    The conventional method of using liquid chromatography to determine the composition of a gaseous mixture entails dissolving vapors in a suitable solvent, then obtaining a chromatograph of the resulting solution. We studied the direct introduction of a gaseous sample into a C18 reversed-phase column, followed by separation of the components by HPLC with UV detection. Since the chromatography was performed at high pressure, vapors readily dissolved in the eluent and the substances separated in the column as effectively as in liquid samples. Samples were injected into the column in two ways: a) through the valve without a flow stop; b) after stopping the flow and relieving all pressure. We showed that an injectable gas volume could reach 70% of column dead volume. When an injected gaseous sample volume was less than 10% of the column dead volume, the resulting peaks were symmetrical and the column efficiency was high. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Comparison of gas chromatography/isotope ratio mass spectrometry and liquid chromatography/isotope ratio mass spectrometry for carbon stable-isotope analysis of carbohydrates

    NARCIS (Netherlands)

    Moerdijk-Poortvliet, T.C.W.; Schierbeek, H.; Houtekamer, M.; van Engeland, T.; Derrien, D.; Stal, L.J.; Boschker, H.T.S.

    2015-01-01

    Rationale: We compared gas chromatography/isotope ratio mass spectrometry (GC/IRMS) and liquid chromatography/isotope ratio mass spectrometry (LC/IRMS) for the measurement of δ13C values in carbohydrates. Contrary to GC/IRMS, no derivatisation is needed for LC/IRMS analysis of carbohydrates. Hence,

  19. Comparison of gas chromatography/isotope ratio mass spectrometry and liquid chromatography/isotope ratio mass spectrometry for carbon stable-isotope analysis of carbohydrates

    NARCIS (Netherlands)

    Moerdijk-Poortvliet, T.C.W.; Schierbeek, H.; Houtekamer, M.; van Engeland, T.; Derrien, D.; Stal, L.J.; Boschker, H.T.S.

    2015-01-01

    We compared gas chromatography/isotope ratio mass spectrometry (GC/IRMS) and liquid chromatography/isotope ratio mass spectrometry (LC/IRMS) for the measurement of d13C values in carbohydrates. Contrary to GC/IRMS, no derivatisation is needed for LC/IRMS analysis of carbohydrates. Hence, although

  20. Comparison of gas chromatography/isotope ratio mass spectrometry and liquid chromatography/isotope ratio mass spectrometry for carbon stable-isotope analysis of carbohydrates

    NARCIS (Netherlands)

    Moerdijk-Poortvliet, Tanja C. W.; Schierbeek, Henk; Houtekamer, Marco; van Engeland, Tom; Derrien, Delphine; Stal, Lucas J.; Boschker, Henricus T. S.

    2015-01-01

    We compared gas chromatography/isotope ratio mass spectrometry (GC/IRMS) and liquid chromatography/isotope ratio mass spectrometry (LC/IRMS) for the measurement of δ(13)C values in carbohydrates. Contrary to GC/IRMS, no derivatisation is needed for LC/IRMS analysis of carbohydrates. Hence, although

  1. Direct solid-phase microextraction combined with gas and liquid chromatography for the determination of lidocaine in human urine

    NARCIS (Netherlands)

    Koster, E.H M; Hofman, N.S K; de Jong, G.J.

    Solid-phase microextraction (SPME) has been combined with gas chromatography (GC) and liquid chromatography (LC) for the determination of lidocaine in human urine. A polydimethylsiloxane (PDMS) coated fibre was directly immersed into buffered urine. Extraction conditions such as time, pH, ionic

  2. Preventive doping control analysis: Liquid and gas chromatography time-to-flight mass spectrometry for detection of designer steriods

    NARCIS (Netherlands)

    Georgakopoulos, C.G.; Vonaparti, A.; Stamou, M.; Kiousi, P.; Lyris, E.; Angelis, Y.S.; Tsoupras, G.; Wuest, B.; Nielen, M.W.F.; Panderi, I.; Koupparis, M.

    2007-01-01

    A new combined doping control screening method for the analysis of anabolic steroids in human urine using liquid chromatography/electrospray ionization orthogonal acceleration time-of-flight mass spectrometry (LCoaTOFMS) and gas chromatography/electron ionization orthogonal acceleration

  3. Phytochemical Profile of Erythrina variegata by Using High-Performance Liquid Chromatography and Gas Chromatography-Mass Spectroscopy Analyses.

    Science.gov (United States)

    Muthukrishnan, Suriyavathana; Palanisamy, Subha; Subramanian, Senthilkumar; Selvaraj, Sumathi; Mari, Kavitha Rani; Kuppulingam, Ramalingam

    2016-08-01

    Natural products derived from plant sources have been utilized to treat patients with numerous diseases. The phytochemical constituents present in ethanolic leaf extract of Erythrina variegata (ELEV) were identified by using high-performance liquid chromatography (HPLC) and gas chromatography-mass spectroscopy (GC-MS) analyses. Shade dried leaves were powdered and extracted with ethanol for analyses through HPLC to identify selected flavonoids and through GC-MS to identify other molecules. The HPLC analysis of ELEV showed the presence of gallic and caffeic acids as the major components at concentrations of 2.0 ppm and 0.1 ppm, respectively, as well as other components. GC-MS analysis revealed the presence of 3-eicosyne; 3,7,11,15-tetramethyl-2-hexadecen-1-ol; butanoic acid, 3-methyl-3,7-dimethyl-6-octenyl ester; phytol; 1,2-benzenedicarboxylic acid, diundecyl ester; 1-octanol, 2-butyl-; squalene; and 2H-pyran, 2-(7-heptadecynyloxy) tetrahydro-derivative. Because pharmacopuncture is a new evolving natural mode that uses herbal extracts for treating patients with various ailments with minimum pain and maximum effect, the results of this study are particularly important and show that ELEV possesses a wide range of phytochemical constituents, as indicated above, as effective active principle molecules that can be used individually or in combination to treat patients with various diseases. Copyright © 2016. Published by Elsevier B.V.

  4. Elucidation of urinary metabolites of fluoxymesterone by liquid chromatography-tandem mass spectrometry and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Pozo, Oscar J; Van Thuyne, Wim; Deventer, Koen; Van Eenoo, Peter; Delbeke, Frans T

    2008-03-01

    The suitability of liquid chromatography tandem mass spectrometry (LC-MS/MS) and gas chromatography mass spectrometry (GC-MS) for the elucidation of fluoxymesterone metabolism has been evaluated. Electrospray ionization (ESI) and collision induced dissociation (CID) fragmentation in LC-MS/MS and electron impact spectra (EI) in GC-MS have been studied for fluoxymesterone and two commercially available metabolites. MS(n) experiments and accurate mass measurements performed by an ion-trap analyser and a QTOF instrument respectively have been used for the elucidation of the fragmentation pathway. The neutral loss scan of 20 Da (loss of HF) in LC-MS/MS has been applied for the selective detection of fluoxymesterone metabolites. In a positive fluoxymesterone doping control sample, 9 different analytes have been detected including the parent compound. Seven of these metabolites were also confirmed by GC-MS including 5 previously unreported metabolites. On the basis of the ionization, the CID fragmentation, the accurate mass of the product ions and the EI spectra of these analytes, a tentative elucidation as well as a proposal for the metabolic pathway of fluoxymesterone has been suggested. The presence of these compounds has also been confirmed by the analysis of five other positive fluoxymesterone urine samples. Copyright (c) 2008 John Wiley & Sons, Ltd.

  5. Phytochemical Profile of Erythrina variegata by Using High-Performance Liquid Chromatography and Gas Chromatography-Mass Spectroscopy Analyses

    Directory of Open Access Journals (Sweden)

    Suriyavathana Muthukrishnan

    2016-08-01

    Full Text Available Natural products derived from plant sources have been utilized to treat patients with numerous diseases. The phytochemical constituents present in ethanolic leaf extract of Erythrina variegata (ELEV were identified by using high-performance liquid chromatography (HPLC and gas chromatography-mass spectroscopy (GC-MS analyses. Shade dried leaves were powdered and extracted with ethanol for analyses through HPLC to identify selected flavonoids and through GC-MS to identify other molecules. The HPLC analysis of ELEV showed the presence of gallic and caffeic acids as the major components at concentrations of 2.0 ppm and 0.1 ppm, respectively, as well as other components. GC-MS analysis revealed the presence of 3-eicosyne; 3,7,11,15-tetramethyl-2-hexadecen-1-ol; butanoic acid, 3-methyl-3,7-dimethyl-6-octenyl ester; phytol; 1,2-benzenedicarboxylic acid, diundecyl ester; 1-octanol, 2-butyl-; squalene; and 2H-pyran, 2-(7-heptadecynyloxy tetrahydro-derivative. Because pharmacopuncture is a new evolving natural mode that uses herbal extracts for treating patients with various ailments with minimum pain and maximum effect, the results of this study are particularly important and show that ELEV possesses a wide range of phytochemical constituents, as indicated above, as effective active principle molecules that can be used individually or in combination to treat patients with various diseases.

  6. Gas chromatography-mass spectrometry and high-performance liquid chromatography-diode array detection for dating of paper ink.

    Science.gov (United States)

    Díaz-Santana, Oscar; Vega-Moreno, Daura; Conde-Hardisson, Francisco

    2017-09-15

    An extraction and determination method is shown for the analysis of dyes and solvents present in two types of ballpoint pen inks that are deposited onto paper. Ink extracts are analysed using a combination of gas chromatography with mass spectrometry (GC-MS), and high-pressure liquid chromatography with photodiode array detection (HPLC-DAD), within a single sample extraction procedure. Seventeen solvents and thirteen dyes contained in two Montblanc ® inks (black and blue) were monitored for 45 months at monthly intervals, in order to determine variations in the concentrations of the compounds over time. We also studied the relative variations between different compounds and the generation of degradation products such as phenol. The concentration data obtained from these compounds during their exposure have been analysed and a multiple regression model is developed for each ink type that allows an estimate of the exposure time of the ink on paper with a maximum error of between 4 and 7 months. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Community air monitoring for pesticides-part 2: multiresidue determination of pesticides in air by gas chromatography, gas chromatography-mass spectrometry, and liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Hengel, Matt; Lee, P

    2014-03-01

    Two multiresidue methods were developed to determine pesticides in air collected in California. Pesticides were trapped using XAD-4 resin and extracted with ethyl acetate. Based on an analytical method from the University of California Davis Trace Analytical Laboratory, pesticides were detected by analyzing the extract by gas chromatography-mass spectrometry (GC-MS) to determine chlorothalonil, chlorthal-dimethyl, cycloate, dicloran, dicofol, EPTC, ethalfluralin, iprodione, mefenoxam, metolachlor, PCNB, permethrin, pronamide, simazine, trifluralin, and vinclozolin. A GC with a flame photometric detector was used to determine chlorpyrifos, chlorpyrifos oxon, diazinon, diazinon oxon, dimethoate, dimethoate oxon, fonophos, fonophos oxon, malathion, malathion oxon, naled, and oxydemeton. Trapping efficiencies ranged from 78 to 92 % for low level (0.5 μg) and 37-104 % for high level (50 and 100 μg) recoveries. Little to no degradation of compounds occurred over 31 days; recoveries ranged from 78 to 113 %. In the California Department of Food and Agriculture (CDFA) method, pesticides were detected by analyzing the extract by GC-MS to determine chlorothalonil, chlorpyrifos, cypermethrin, dichlorvos, dicofol, endosulfan 1, endosulfan sulfate, oxyfluorfen, permethrin, propargite, and trifluralin. A liquid chromatograph coupled to a MS was used to determine azinphos-methyl, chloropyrifos oxon, DEF, diazinon, diazinon oxon, dimethoate, dimethoate oxon, diuron, EPTC, malathion, malathion oxon, metolachlor, molinate, norflurazon, oryzalin, phosmet, propanil, simazine and thiobencarb. Trapping efficiencies for compounds determined by the CDFA method ranged from 10 to 113, 22 to 114, and 56 to 132 % for 10, 5, and 2 μg spikes, respectively. Storage tests yielded 70-170 % recovery for up to 28 days. These multiresidue methods represent flexible, sensitive, accurate, and cost-effective ways to determine residues of various pesticides in ambient air.

  8. Characterization of free and bound fatty acids in human gallstones by capillary gas liquid chromatography

    International Nuclear Information System (INIS)

    Channa, N.A.; Khand, F.D.; Noorani, M.A.; Bhanger, M.I.

    2002-01-01

    Forty-four human gallstone samples either of pure cholesterol or cholesterol and bilirubin were randomly selected and analyzed by capillary gas liquid chromatography for the relative percentage composition of free and total fatty acids. The results showed that bound fatty acids were present in higher amounts than the free fatty acids. Amongst the bound fatty acids the percentage occurrence for palmitic acid was highest followed by stearic, oleic, linoleic and myristic acids. Fatty acids myristic, palmitic and linoleic were present in higher amounts in cholesterol gallstones, whereas stearic acid in cholesterol and bilirubin gallstones. When compared, no significant difference (p < 0.05) in the levels of free and bound fatty acids were seen in gallstones of males and females. The results suggest that bound fatty acids have a role to play in the structure of gallstones. (author)

  9. Determination of Levetiracetam in Human Plasma by Dispersive Liquid-Liquid Microextraction Followed by Gas Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Greyce Kelly Steinhorst Alcantara

    2016-01-01

    Full Text Available Levetiracetam (LEV is an antiepileptic drug that is clinically effective in generalized and partial epilepsy syndromes. The use of this drug has been increasing in clinical practice and intra- or -interindividual variability has been exhibited for special population. For this reason, bioanalytical methods are required for drug monitoring in biological matrices. So this work presents a dispersive liquid-liquid microextraction method followed by gas chromatography-mass spectrometry (DLLME-GC-MS for LEV quantification in human plasma. However, due to the matrix complexity a previous purification step is required. Unlike other pretreatment techniques presented in the literature, for the first time, a procedure employing ultrafiltration tubes Amicon® (10 kDa porous size without organic solvent consumption was developed. GC-MS analyses were carried out using a linear temperature program, capillary fused silica column, and helium as the carrier gas. DLLME optimized parameters were type and volume of extraction and dispersing solvents, salt addition, and vortex agitation time. Under chosen parameters (extraction solvent: chloroform, 130 μL; dispersing solvent: isopropyl alcohol, 400 μL; no salt addition and no vortex agitation time, the method was completely validated and all parameters were in agreement with the literature recommendations. LEV was quantified in patient’s plasma sample using less than 550 μL of organic solvent.

  10. Research into the group composition of tar using the gas liquid chromatography method

    Energy Technology Data Exchange (ETDEWEB)

    Lisin, S.N.; Stepanov, Yu.V.; Lisina, L.A.; Chistyakov, A.N.

    1986-03-01

    This paper first gives a brief review of current methods used for determining chemical composition of tars, then describes experiments using gas liquid chromatography (GLC) to determine the chemical composition of delta/sub 1/, delta/sub 2/, delta, and delta fractions of medium temperature tars obtained during normal solvent processing (isooctane, toluene, quinoline). For delta and delta fractions, a Tsvet-104 chromatograph was used with a flame-ionization detector under the following conditions: column height 3 m, diameter 3 mm, AW-HMDS filler, 0.25-0.36 mm fractions with 5% SE-30, linear column temperature increase from 50-310/sup 0/C, velocity 6 C/min, condenser temperature 350/sup 0/C, velocity of carrier gas (helium) and hydrogen 100 ml/min, air consumption 1.5 l/min. delta/sub 1/ and delta/sub 2/ fractions were determined using a GC-IC chromatograph (manufactured by Shimatsu) under conditions analogous to those given above. Conclusion is that the yield of chromatographable compounds from tar by the GLC method with temperature programming is practically constant for each tar and can be characterized by the delta fraction content and its chemical composition. A method of determining the group composition of tars and the chemical composition of the delta fraction using GLC is proposed. 13 refs.

  11. Quantitative determination of methamphetamine in oral fluid by liquid-liquid extraction and gas chromatography/mass spectrometry.

    Science.gov (United States)

    Bahmanabadi, L; Akhgari, M; Jokar, F; Sadeghi, H B

    2017-02-01

    Methamphetamine abuse is one of the most medical and social problems many countries face. In spite of the ban on the use of methamphetamine, it is widely available in Iran's drug black market. There are many analytical methods for the detection of methamphetamine in biological specimen. Oral fluid has become a popular specimen to test for the presence of methamphetamine. The purpose of the present study was to develop a method for the extraction and detection of methamphetamine in oral fluid samples using liquid-liquid extraction (LLE) and gas chromatography/mass spectrometry (GC/MS) methods. An analytical study was designed in that blank and 50 authentic oral fluid samples were collected to be first extracted by LLE and subsequently analysed by GC/MS. The method was fully validated and showed an excellent intra- and inter-assay precision (reflex sympathetic dystrophy ˂ 10%) for external quality control samples. Recovery with LLE methods was 96%. Limit of detection and limit of quantitation were 5 and 15 ng/mL, respectively. The method showed high selectivity, no additional peak due to interfering substances in samples was observed. The introduced method was sensitive, accurate and precise enough for the extraction of methamphetamine from oral fluid samples in forensic toxicology laboratories.

  12. Comprehensive lipidomic analysis of human plasma using multidimensional liquid- and gas-phase separations: Two-dimensional liquid chromatography-mass spectrometry vs. liquid chromatography-trapped-ion-mobility-mass spectrometry.

    Science.gov (United States)

    Baglai, Anna; Gargano, Andrea F G; Jordens, Jan; Mengerink, Ynze; Honing, Maarten; van der Wal, Sjoerd; Schoenmakers, Peter J

    2017-12-29

    Recent advancements in separation science have resulted in the commercialization of multidimensional separation systems that provide higher peak capacities and, hence, enable a more-detailed characterization of complex mixtures. In particular, two powerful analytical tools are increasingly used by analytical scientists, namely online comprehensive two-dimensional liquid chromatography (LC×LC, having a second-dimension separation in the liquid phase) and liquid chromatography-ion mobility-spectrometry (LC-IMS, second dimension separation in the gas phase). The goal of the current study was a general assessment of the liquid-chromatography-trapped-ion-mobility-mass spectrometry (LC-TIMS-MS) and comprehensive two-dimensional liquid chromatography-mass spectrometry (LC×LC-MS) platforms for untargeted lipid mapping in human plasma. For the first time trapped-ion-mobility spectrometry (TIMS) was employed for the separation of the major lipid classes and ion-mobility-derived collision-cross-section values were determined for a number of lipid standards. The general effects of a number of influencing parameters have been inspected and possible directions for improvements are discussed. We aimed to provide a general indication and practical guidelines for the analyst to choose an efficient multidimensional separation platform according to the particular requirements of the application. Analysis time, orthogonality, peak capacity, and an indicative measure for the resolving power are discussed as main characteristics for multidimensional separation systems. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Quantification of liquid products from the electroreduction of CO2 and CO using static headspace-gas chromatography and nuclear magnetic resonance spectroscopy

    DEFF Research Database (Denmark)

    Bertheussen, Erlend; Abghoui, Younes; Jovanov, Zarko P.

    2017-01-01

    Static headspace-gas chromatography (HS-GC) useful for ex-situ liquid product analysis. Could complement high-performance liquid chromatography and NMR spectroscopy. Particularly high sensitivity towards compounds with high vapor pressure. Detection limits below 0.5μM were shown for acetaldehyde ...

  14. Gas-liquid chromatography of bacterial fatty acids with a fused-silica capillary column.

    OpenAIRE

    Moss, C W; Dees, S B; Guerrant, G O

    1980-01-01

    The use of flexible, fused-silica capillary column for gas-liquid chromatographic analysis of bacterial fatty acids is illustrated with Propionibacterium acnes, Propionibacterium shermanii, and a standard methyl ester mixture.

  15. Analysis of s-triazine herbicides in model systems and samples of groundwater by gas and liquid chromatography

    Directory of Open Access Journals (Sweden)

    Kostadinović Ljiljana

    2010-01-01

    Full Text Available In this paper, residues of s-triazine herbicides (Simazine, Atrazine, Amethrine, Promethrine and Azyprothrine have been determined in samples of model systems and real groundwater samples by gas-chromatography and high performance liquid chromatography. S-triazine herbicides were isolated from water samples by chloroform-methanol mixture (1:1, followed by purification of extract on the Al2O3 column. Gas-chromatographic determination the residues of s-triazines is performed on parallel capilar columns ULTRA I and ULTRA II, using specific NP detector. Liquid-chromatographic determination the s-triazines was performed on the column TSK ODS-120 A 5 mm 'LKB', using the mobile phase methanol-water (60:40. Total concentration of s-triazines in samples of Danube water was 3.54 mg dm-3. .

  16. Determination of organophosphorus pesticides by dispersive liquid-liquid micro extraction coupled with gas chromatography-electron capture detection

    International Nuclear Information System (INIS)

    Mohd Marsin Sanagi; Siti Umairah Mokhtar; Mazidatul Akmam Miskam; Wan Aini Wan Ibrahim

    2011-01-01

    A simple, rapid and sensitive method termed as dispersive liquid-liquid micro extraction (DLLME) combined with gas chromatography-electron capture detector (GC-ECD) was developed for the determination of selected organophosphorus pesticides (OPPs) namely chloropyrifos, dimethoate and diazinon in water sample. In this method, a mixture of carbon disulfide, CS 2 (extraction solvent) and methanol (disperser solvent) was rapidly injected using syringe into the 5.00 mL water sample to form a cloudy solution where the OPPs were extracted into the fine droplets of extraction solvent. Upon centrifugation for 3 min at 3500 rpm, the fine droplets were sedimented at the bottom of the centrifuge tube. Sedimented phase (1 μL) was injected into the GC-ECD for separation and determination of OPPs. Important extraction parameters, such as type of disperser solvent, volume of extraction solvent and volume of disperser solvent were investigated. The optimized conditions for DLLME of the selected OPPs were methanol as disperser solvent, 30 μL of extraction solvent (CS 2 ) and 1.0 mL of disperser solvent (methanol). Under the optimum extraction conditions, the method showed good linearity in the range of 0.1 to 1.0 μg/ mL with correlation coefficient (r 2 ), in the range of 0.9976 to 0.9994 and low limits of detection (LOD) between 0.047 and 0.201 μg/ mL. The proposed method provided acceptable recoveries (72.67- 144 %) with good RSDs ranging from 2.74 % to 7.48 %. This method was successfully applied to the determination of OPPs in water samples obtained from a golf course and chloropyrifos and diazinon were detected at concentration 0.18 μg/ mL and 0.07 μg/ mL, respectively. (author)

  17. Quantitative Analysis of Tetramethylenedisulfotetramine ("Tetramine") Spiked into Beverages by Liquid Chromatography Tandem Mass Spectrometry with Validation by Gas Chromatography Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Owens, J; Hok, S; Alcaraz, A; Koester, C

    2008-11-13

    Tetramethylenedisulfotetramine, commonly known as tetramine, is a highly neurotoxic rodenticide (human oral LD{sub 50} = 0.1 mg/kg) used in hundreds of deliberate food poisoning events in China. Here we describe a method for quantitation of tetramine spiked into beverages, including milk, juice, tea, cola, and water and cleaned up by C8 solid phase extraction and liquid-liquid extraction. Quantitation by high performance liquid chromatography tandem mass spectrometry (LC/MS/MS) was based upon fragmentation of m/z 347 to m/z 268. The method was validated by gas chromatography mass spectrometry (GC/MS) operated in SIM mode for ions m/z 212, 240, and 360. The limit of quantitation was 0.10 {micro}g/mL by LC/MS/MS versus 0.15 {micro}g/mL for GC/MS. Fortifications of the beverages at 2.5 {micro}g/mL and 0.25 {micro}g/mL were recovered ranging from 73-128% by liquid-liquid extraction for GC/MS analysis, 13-96% by SPE and 10-101% by liquid-liquid extraction for LC/MS/MS analysis.

  18. Quantitative Analysis of Tetramethylenedisulfotetramine ('Tetramine') Spiked into Beverages by Liquid Chromatography Tandem Mass Spectrometry with Validation by Gas Chromatography Mass Spectrometry

    International Nuclear Information System (INIS)

    Owens, J.; Hok, S.; Alcaraz, A.; Koester, C.

    2008-01-01

    Tetramethylenedisulfotetramine, commonly known as tetramine, is a highly neurotoxic rodenticide (human oral LD 50 = 0.1 mg/kg) used in hundreds of deliberate food poisoning events in China. Here we describe a method for quantitation of tetramine spiked into beverages, including milk, juice, tea, cola, and water and cleaned up by C8 solid phase extraction and liquid-liquid extraction. Quantitation by high performance liquid chromatography tandem mass spectrometry (LC/MS/MS) was based upon fragmentation of m/z 347 to m/z 268. The method was validated by gas chromatography mass spectrometry (GC/MS) operated in SIM mode for ions m/z 212, 240, and 360. The limit of quantitation was 0.10 (micro)g/mL by LC/MS/MS versus 0.15 (micro)g/mL for GC/MS. Fortifications of the beverages at 2.5 (micro)g/mL and 0.25 (micro)g/mL were recovered ranging from 73-128% by liquid-liquid extraction for GC/MS analysis, 13-96% by SPE and 10-101% by liquid-liquid extraction for LC/MS/MS analysis.

  19. Determination of the Volatile Fatty Acid Content in the Rumen Liquid: Comparison of Gas Chromatography and Capillary Isotachophoresis

    Directory of Open Access Journals (Sweden)

    Jaroslav Filípek

    2009-01-01

    Full Text Available Two analytical procedures for determining volatile fatty acids in the rumen liquid were compared: capillary isotachophoresis (ITP and gas chromatography. Acetic acid, propionic acid, butyric and valeric acids were determined. No significant differences (n = 53, P ≥ 0.05 have been identified in the amounts of acetic and propionic acids and the results are highly consistent. For butyric acid, the method of gas chromatography yielded higher results with a constant error of approximately 0.5 mmol/l in the whole range of concentration. In terms of diagnostics, however, this size of error is non-significant. In the case of valeric acid a proportional error was found. Gas chromatography yielded higher values, the difference being greater for the low values while for the higher values the results are almost identical. However, valeric acid is a minor acid and its determination is of secondary significance to rumen fermentation assessment. The gas chromatography method is able to clearly differentiate between n and iso forms in the case of butyric and valeric acids. It can be stated that the two analytical methods yield comparable results and both can be used for the needs of practical diagnostics.

  20. Study of the influence of surfactants on the transfer of gases into liquids by inverse gas chromatography.

    Science.gov (United States)

    Atta, Khan Rashid; Gavril, Dimitrios; Loukopoulos, Vassilios; Karaiskakis, George

    2004-01-16

    The experimental technique of the reversed-flow version of inverse gas chromatography was applied for the study of effects of surfactants in reducing air-water exchange rates. The vinyl chloride (VC)-water system was used as a model, which is of great importance in environmental chemistry. Using suitable mathematical analysis, various physicochemical quantities were calculated, among which the most significant are: Partition coefficients of the VC gas between the surfactant interface and the carrier gas nitrogen, as well as between the bulk of the water + surfactant solution and the carrier gas nitrogen, overall mass transfer coefficients of VC in the liquid (water + surfactant) and the gas (nitrogen) phases, water and surfactant film transfer coefficients, nitrogen, water and surfactant phase resistances for the transfer of VC into the water solution, relative resistance of surfactant in the transfer of VC into the bulk of solution, exchange velocity of VC between nitrogen and the liquid solution, and finally the thickness of the surfactant stagnant film in the liquid phase, according to the three phase resistance model. From the variation of the above parameters with the surfactant's concentration, important conclusions concerning the effects of surfactants on the transfer of a gas at the air-liquid interface, as well as to the bulk of the liquid were extracted. An interesting finding of this work was also that by successive addition of surfactant, the critical micelle concentration of surfactant was obtained, after which follows a steady-state for the transfer of the gas into the water body, which could be attributed to the transition from mono- to multi-layer state.

  1. performance liquid chromatography

    African Journals Online (AJOL)

    user

    2010-11-22

    Nov 22, 2010 ... ISSN 1684–5315 © 2010 Academic Journals. Full Length Research Paper. Determination ... Key words: Processed food, high-performance liquid chromatography, acrylamide, health hazard. INTRODUCTION. In the year 2002, the ... potatoes, breakfast cereals etc. It was thus confirmed that acrylamide has ...

  2. [Analysis of volatile oil in Illicium verum fruit by on-line coupled packed capillary liquid chromatography/capillary gas chromatography].

    Science.gov (United States)

    Wang, Xiaochun; Wang, Hanwen; Ma, Jiping; Xu, Ye; Guan, Yafeng

    2004-03-01

    Volatile oil in Illicillm Verum Fruit was analyzed by on-line coupled packed capillary high performance liquid chromatography/capillary gas chromatography (micro-HPLC-CGC). A micro-HPLC column of 250 mm x 0.32 mm i.d. packed with 5 microm cyano-bonded silica stationary phase was used for group separation. n-Hexane/acetonitrile/dichloromethane (80:8:12, v/v) was used as mobile phase at a flow rate of 1.8 microL/min. Five groups of eluents from the micro-HPLC were collected and stored in a multi-loop interface, which were then transferred to a capillary gas chromatograph sequentially for further analysis. A 10 m x 0.53 mm i.d. retention gap connected with a 30 m x 0.53 mm i.d. x 1.0 microm SE-54 analytical column was used for CGC analysis. In-column splitless injection mode was adopted for better quantitation and manipulation of chromatograms. Five chromatograms were obtained and compared with the result of direct CGC analysis of the same sample. It was found that there were at least 3 new compounds that were not found nor separated before by conventional capillary gas chromatography/mass spectrometry method.

  3. Determination of gas-liquid partition coefficients of several organic solutes in trihexyl(tetradecyl)phosphonium bromide using capillary gas chromatography columns.

    Science.gov (United States)

    Ronco, Nicolás R; Menestrina, Fiorella; Romero, Lílian M; Castells, Cecilia B

    2017-06-09

    In this paper, we report gas-liquid partition constants for thirty-five volatile organic solutes in the room temperature ionic liquid trihexyl(tetradecyl)phosphonium bromide measured by gas-liquid chromatography using capillary columns. The relative contribution of gas-liquid partition and interfacial adsorption to retention was evaluated through the use of columns with different the phase ratio. Four capillary columns with exactly known phase ratios were constructed and employed to measure the solute retention factors at four temperatures between 313.15 and 343.15K. The partition coefficients were calculated from the slopes of the linear regression between solute retention factors and the reciprocal of phase ratio at a given temperature according to the gas-liquid chromatographic theory. Gas-liquid interfacial adsorption was detected for a few solutes and it has been considered for the calculations of partition coefficient. Reliable solute's infinite dilution activity coefficients can be obtained when retention data are determined by a unique partitioning mechanism. The partial molar excess enthalpies at infinite dilution have been estimated from the dependence of experimental values of solute activity coefficients with the column temperature. A thorough discussion of the uncertainties of the experimental measurements and the main advantages of the use of capillary columns to acquire the aforementioned relevant thermodynamic information was performed. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Analysis of small carbohydrates in several bioactive botanicals by gas chromatography with mass spectrometry and liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Moldoveanu, Serban; Scott, Wayne; Zhu, Jeff

    2015-11-01

    Bioactive botanicals contain natural compounds with specific biological activity, such as antibacterial, antioxidant, immune stimulating, and taste improving. A full characterization of the chemical composition of these botanicals is frequently necessary. A study of small carbohydrates from the plant materials of 18 bioactive botanicals is further described. The study presents the identification of the carbohydrate using a gas chromatographic-mass spectrometric analysis that allows detection of molecules as large as maltotetraose, after changing them into trimethylsilyl derivatives. A number of carbohydrates in the plant (fructose, glucose, mannose, sucrose, maltose, xylose, sorbitol, and myo-, chiro-, and scyllo-inositols) were quantitated using a novel liquid chromatography with tandem mass spectrometric technique. Both techniques involved new method developments. The gas chromatography with mass spectrometric analysis involved derivatization and separation on a Rxi(®)-5Sil MS column with H2 as a carrier gas. The liquid chromatographic separation was obtained using a hydrophilic interaction type column, YMC-PAC Polyamine II. The tandem mass spectrometer used an electrospray ionization source in multiple reaction monitoring positive ion mode with the detection of the adducts of the carbohydrates with Cs(+) ions. The validated quantitative procedure showed excellent precision and accuracy allowing the analysis in a wide range of concentrations of the analytes. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. A new concept of hollow fiber liquid-liquid-liquid microextraction compatible with gas chromatography based on two immiscible organic solvents.

    Science.gov (United States)

    Ghambarian, Mahnaz; Yamini, Yadollah; Esrafili, Ali; Yazdanfar, Najmeh; Moradi, Morteza

    2010-09-03

    A new concept of liquid-liquid-liquid microextraction (LLLME) was introduced based on applying two immiscible organic solvents in lumen and wall pores of hollow fiber (HF). With this methodology, analytes of interest can be extracted from aqueous sample, into a thin layer of organic solvent (dodecane) sustained in the pores of a porous hollow fiber, and further into a muL volume of organic acceptor (acetonitrile or methanol) located inside the lumen of the hollow fiber. Some chlorophenols (CPs) were selected as model compounds for developing and evaluating of the method performance. The analysis was performed by gas chromatography-electron capture detection (GC-ECD) without derivatization. The factors affecting the HF-LLLME of target compounds were investigated and the optimal extraction conditions were established. Under the optimum conditions, preconcentration factors in a range of 208-895 were obtained. The performance of the proposed method was studied in terms of linear dynamic ranges (LDRs from 0.02 to 100ngmL(-1)), linearity (R(2)> or =0.995), precision (RSD %HF-LLLME also served as a technique for sample clean-up. 2010 Elsevier B.V. All rights reserved.

  6. Simultaneous determination of oxalic, citric, nitrilotriacetic and ethylenediamenetetraacetic acids by gas liquid chromatography of their methyl esters

    International Nuclear Information System (INIS)

    Eskell, C.J.; Pick, M.E.

    1980-04-01

    A procedure for simultaneous determination of ethylenediaminetetraacetic acid (EDTA), nitrilotriacetic acid (NTA), citric acid and oxalic acid by gas liquid chromatography is described. The involatile acids are first concerted to their volatile methyl ester derivatives by reaction with boron trifluoride in methanol. Transition metal ions (Fe 3+ , Cr 3+ and Ni 2+ ) which will be present in decontamination liquors from nuclear reactors, and form strong chelates with the acids, have been shown to cause no interference to the esterification reaction. The esters were separated by temperature programming on a 3.5 metre capillary column packed with 3% OV1 on Diatomite CQ and were detected by flame ionisation. (author)

  7. Determination of chlorobenzenes in textiles by pressurized hot water extraction followed by vortex-assisted liquid-liquid microextraction and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Lu, Yang; Zhu, Yan

    2013-12-06

    A method for quantitative determination of chlorobenzenes in textiles is developed, using pressurized hot water extraction (PHWE), vortex-assisted liquid-liquid microextraction (VALLME) and gas chromatography-mass spectrometry (GC-MS). VALLME serves as a trapping step after PHWE. The extraction conditions are investigated, as well as the quantitative features such as linearity, limits of detection (LODs), limits of quantification (LOQs), repeatabilities and reproducibilities between days. LOQs of 0.018-0.032mg/kg were achieved. The present method provides good repeatabilities (RSDtextiles. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Gas chromatography in space

    Science.gov (United States)

    Akapo, S. O.; Dimandja, J. M.; Kojiro, D. R.; Valentin, J. R.; Carle, G. C.

    1999-01-01

    Gas chromatography has proven to be a very useful analytical technique for in situ analysis of extraterrestrial environments as demonstrated by its successful operation on spacecraft missions to Mars and Venus. The technique is also one of the six scientific instruments aboard the Huygens probe to explore Titan's atmosphere and surface. A review of gas chromatography in previous space missions and some recent developments in the current environment of fiscal constraints and payload size limitations are presented.

  9. Simulating Retention in Gas-Liquid Chromatography: Benzene, Toluene, and Xylene Solutes

    Energy Technology Data Exchange (ETDEWEB)

    WICK,COLLIN D.; MARTIN,MARCUS G.; SIEPMANN, J. ILJA; SCHURE,MARK R.

    2000-07-12

    Accurate predictions of retention times, retention indices, and partition constants are a long sought-after goal for theoretical studies in chromatography. Although advances in computational chemistry have improved the understanding of molecular interactions, little attention has been focused on chromatography, let alone calculations of retention properties. Configurational-bias Monte Carlo simulations in the isobaric-isothermal Gibbs ensemble were used to investigate the partitioning of benzene, toluene, and the three xylene isomers between a squalane liquid phase and a helium vapor phase. The united-atom representation of the TraPPE (Transferable Potentials for Phase Equilibria) force field was used for all solutes and squalane. The Gibbs free energies of transfer and Kovats retention indices of the solutes were calculated directly from the partition constants (which were averaged over several independent simulations). While the calculated Kovats indices of benzene and toluene at T = 403 K are significantly higher than their experimental counterparts, much better agreement is found for the xylene isomers at T = 365 K.

  10. Reversed-phase liquid chromatography coupled on-line with capillary gas chromatography use of an anion-exchange membrane to remove an ion-pair reagent from the eluent.

    NARCIS (Netherlands)

    Brinkman, U.A.T.; Goosens, E.C.; de Jong, D.; de Jong, G.J.; Beerthuizen, I.M.

    1995-01-01

    In order to enable the coupling of reversed-phase liquid chromatography (RPLC) with capillary gas chromatography (GC), the performance of an anion-exchange micromembrane device has been studied to remove the ion-pair reagent methanesulphonic acid from an acetonitrile/water LC eluent. The regenerant

  11. Accelerated solvent extraction combined with dispersive liquid-liquid microextraction before gas chromatography with mass spectrometry for the sensitive determination of phenols in soil samples.

    Science.gov (United States)

    Xing, Han-Zhu; Wang, Xia; Chen, Xiang-Feng; Wang, Ming-Lin; Zhao, Ru-Song

    2015-05-01

    A method combining accelerated solvent extraction with dispersive liquid-liquid microextraction was developed for the first time as a sample pretreatment for the rapid analysis of phenols (including phenol, m-cresol, 2,4-dichlorophenol, and 2,4,6-trichlorophenol) in soil samples. In the accelerated solvent extraction procedure, water was used as an extraction solvent, and phenols were extracted from soil samples into water. The dispersive liquid-liquid microextraction technique was then performed on the obtained aqueous solution. Important accelerated solvent extraction and dispersive liquid-liquid microextraction parameters were investigated and optimized. Under optimized conditions, the new method provided wide linearity (6.1-3080 ng/g), low limits of detection (0.06-1.83 ng/g), and excellent reproducibility (extraction with dispersive liquid-liquid microextraction as a sample pretreatment procedure coupled with gas chromatography and mass spectrometry is an excellent method for the rapid analysis of trace levels of phenols in environmental soil samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Detection of radiation-induced hydrocarbons in Camembert irradiated before and after the maturing process-comparison of florisil column chromatography and on-line coupled liquid chromatography-gas chromatography

    International Nuclear Information System (INIS)

    Schulzki, G.; Spiegelberg, A.; Bögl, K.W.; Schreiber, G.A.

    1995-01-01

    The influence of the maturing process on the detection of radiation-induced volatile hydrocarbons in the fat of Camembert has been investigated. Two analytical methods for separation of the hydrocarbon fraction from the lipid were applied: Florisil column chromatography with subsequent gas chromatographic-mass spectrometric (GC-MS) determination as well as on-line coupled liquid chromatography-GC-MS. The maturing process had no influence on the detection of radiation-induced volatiles. Comparable results were achieved with both analytical methods. However, preference is given to the more effective on-line coupled LC-GC method

  13. Activity coefficients at infinite dilution for solutes in the trioctylmethylammonium bis(trifluoromethylsulfonyl)imide ionic liquid using gas-liquid chromatography

    International Nuclear Information System (INIS)

    Gwala, Nobuhle V.; Deenadayalu, Nirmala; Tumba, Kaniki; Ramjugernath, Deresh

    2010-01-01

    The activity coefficient at infinite dilution (γ 13 ∞ ) for 30 solutes: alkanes, alkenes, cycloalkanes, alkynes, ketones, alcohols, and aromatic compounds was determined from gas-liquid chromatography (glc) measurements at three temperatures (303.15, 313.15, and 323.15) K. The ionic liquid: trioctylmethylammonium bis(trifluoromethylsulfonyl)imide, was used as the stationary phase. For each temperature, γ 13 ∞ values were determined using two columns with different mass percent packing of the ionic liquid. The selectivity (S 12 ∞ ) value was calculated from the γ 13 ∞ to determine the suitability of the solvent as a potential entrainer for extractive distillation in the separation of an hexane/benzene mixture, indicative of a typical industrial separation problem for benchmarking purposes.

  14. Improved sensitivity using liquid chromatography mass spectrometry ...

    African Journals Online (AJOL)

    Improved sensitivity using liquid chromatography mass spectrometry (LC-MS) for detection of propyl chloroformate derivatised β-N-methylamino-L-alanine (BMAA) in ... We show a 10-fold increase in sensitivity with the LC-MS method compared to the previously published gas chromatography mass spectrometry (GC-MS) ...

  15. Determination of polychlorinated biphenyls in water using dynamic hollow fiber liquid-phase microextraction and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Li, Guanhua; Zhang, Lijun; Zhang, Zhanen

    2008-09-12

    The application of dynamic hollow fiber liquid-phase microextraction (dynamic HF-LPME) and gas chromatography-mass spectrometry (GC-MS) for the determination of trace amounts of polychlorinated biphenyls (PCBs) in water was investigated. The experimental parameters were optimized. Under the optimum conditions, the concentration enrichment factors for PCBs were from 718-fold to 840-fold. The calibration curves were linear over a range of 0.05-90 microg/L, with a correlation coefficient (r(2)) of 0.9957-0.9979. The relative standard deviation (RSD) ranged from 3.4% to 5.8% for intra-day variation and from 4.1% to 7.3% for inter-day variation. The limits of detection (LODs, S/N=3:1) were in the range of 13-41 ng/L. The recoveries for spiked water samples ranged from 85.9% to 92.0%.

  16. Argentation gas chromatography revisited: Separation of light olefin/paraffin mixtures using silver-based ionic liquid stationary phases.

    Science.gov (United States)

    Nan, He; Zhang, Cheng; Venkatesh, Amrit; Rossini, Aaron J; Anderson, Jared L

    2017-11-10

    Silver ion or argentation chromatography utilizes stationary phases containing silver ions for the separation of unsaturated compounds. In this study, a mixed-ligand silver-based ionic liquid (IL) was evaluated for the first time as a gas chromatographic (GC) stationary phase for the separation of light olefin/paraffin mixtures. The selectivity of the stationary phase toward olefins can be tuned by adjusting the ratio of silver ion and the mixed ligands. The maximum allowable operating temperature of these stationary phases was determined to be between 125°C and 150°C. Nuclear magnetic resonance (NMR) spectroscopy was used to characterize the coordination behavior of the silver-based IL as well as provide an understanding into the retention mechanism of light olefins. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Determination of the solubility parameter of ionic liquid 1-butyl-3-methylimidazolium tetrafluoroborate by inverse gas chromatography.

    Science.gov (United States)

    Ma, Xiaohong; Wang, Qiang; Li, Xiaoping; Tang, Jun; Zhang, Zhengfang

    2015-11-01

    Thermodynamic properties of ionic liquid 1-butyl-3-methylimidazolium tetrafluoroborate ([BMIM] BF4) were determined via inverse gas chromatography (IGC). Two groups of solvents with different chemical natures and polarities were used to obtain information about [BMIM] BF4-solvent interactions. The specific retention volume, molar heat of sorption, weight fraction activity coefficient, Flory-Huggins interaction parameter as well as solubility parameter were also determined in a temperature range of 333 - 373 K. The results showed that the selected solvents n-C10 to n-C12, carbon tetrachloride, cyclohexane and toluene were poor solvents for [BMIM] BF4, while dichloromethane, acetone, chloroform, methyl acetate, ethanol and methanol were favorite solvents for [BMIM] BF4. In addition, the solubility parameter of [ BMIM] BF4 was determined as 23.39 (J/cm3)0.5 by the extrapolation at 298 K. The experiment proved that IGC was a simple and accurate method to obtain the thermodynamic properties of ionic liquids. This study could be used as a reference to the application and research of the ionic liquids.

  18. On-line liquid chromatography-gas chromatography: A novel approach for the analysis of phytosterol oxidation products in enriched foods.

    Science.gov (United States)

    Scholz, Birgit; Wocheslander, Stefan; Lander, Vera; Engel, Karl-Heinz

    2015-05-29

    A novel methodology for the automated qualitative and quantitative determination of phytosterol oxidation products in enriched foods via on-line liquid chromatography-gas chromatography (LC-GC) was established. The approach is based on the LC pre-separation of acetylated phytosterols and their corresponding oxides using silica as stationary phase and a mixture of n-hexane/methyl tert-butyl ether/isopropanol as eluent. Two LC-fractions containing (i) 5,6-epoxy- and 7-hydroxyphytosterols, and (ii) 7-ketophytosterols are transferred on-line to the GC for the analysis of their individual compositions on a medium polar trifluoropropylmethyl polysiloxane capillary column. Thus, conventionally employed laborious off-line purification and enrichment steps can be avoided. Validation data, including recovery, repeatability, and reproducibility of the method, were elaborated using an enriched margarine as example. The margarine was subjected to a heating procedure in order to exemplarily monitor the formation of phytosterol oxidation products. Quantification was performed using on-line LC-GC-FID, identification of the analytes was based on on-line LC-GC-MS. The developed approach offers a new possibility for the reliable and fast analysis of phytosterol oxidation products in enriched foods. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Phytochemical analyses of Ziziphus jujuba Mill. var. spinosa seed by ultrahigh performance liquid chromatography-tandem mass spectrometry and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Yang, Bao; Yang, Hongshun; Chen, Feng; Hua, Yanglin; Jiang, Yueming

    2013-11-21

    Ziziphus jujuba Mill. var. spinosa (Z. jujuba) seeds have attracted much attention within the field of medicine due to their significant effects against disturbances of the central nervous system. Secondary metabolites composition is key to the influence of the pharmaceutical and commercial qualities of this plant. In this work, the phytochemical profile of Z. jujuba seeds was analysed by ultrahigh performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) and gas chromatography-mass spectrometry (GC-MS). The UPLC-MS/MS information identified the main secondary metabolites in Z. jujuba seeds, including flavonoid C-glycosides, triterpene acids and unsaturated fatty acids. The leading chemical identified by UPLC-MS/MS was betulinic acid, and oleic acid was the leading volatile from the GC-MS results. All the samples tested showed similar phytochemical profiles, but levels of the chemical compounds varied. Principal component analysis revealed the principal secondary metabolites that could define the differences in quality. It was confirmed that the combination of UPLC-MS/MS and GC-MS was an effective technique to demonstrate the pharmaceutical quality of Z. jujuba seeds.

  20. Alkaloids Profiling of Fumaria capreolata by Analytical Platforms Based on the Hyphenation of Gas Chromatography and Liquid Chromatography with Quadrupole-Time-of-Flight Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    María del Mar Contreras

    2017-01-01

    Full Text Available Two analytical platforms, gas chromatography (GC coupled to quadrupole-time-of-flight (QTOF mass spectrometry (MS and reversed-phase ultrahigh performance liquid chromatography (UHPLC coupled to diode array (DAD and QTOF detection, were applied in order to study the alkaloid profile of Fumaria capreolata. The use of these mass analyzers enabled tentatively identifying the alkaloids by matching their accurate mass signals and suggested molecular formulae with those previously reported in libraries and databases. Moreover, the proposed structures were corroborated by studying their fragmentation pattern obtained by both platforms. In this way, 8 and 26 isoquinoline alkaloids were characterized using GC-QTOF-MS and RP-UHPLC-DAD-QTOF-MS, respectively, and they belonged to the following subclasses: protoberberine, protopine, aporphine, benzophenanthridine, spirobenzylisoquinoline, morphinandienone, and benzylisoquinoline. Moreover, the latter analytical method was selected to determine at 280 nm the concentration of protopine (9.6 ± 0.7 mg/g, a potential active compound of the extract. In conclusion, although GC-MS has been commonly used for the analysis of this type of phytochemicals, RP-UHPLC-DAD-QTOF-MS provided essential complementary information. This analytical method can be applied for the quality control of phytopharmaceuticals containing Fumaria extracts currently found in the market.

  1. On-line coupled high performance liquid chromatography-gas chromatography for the analysis of contamination by mineral oil. Part 1: method of analysis.

    Science.gov (United States)

    Biedermann, Maurus; Grob, Koni

    2012-09-14

    For the analysis of mineral oil saturated hydrocarbons (MOSH) and mineral oil aromatic hydrocarbons (MOAH), on-line coupled high performance liquid chromatography-gas chromatography-flame ionization detection (HPLC-GC-FID) offers important advantages: it separates MOSH and MOAH in robust manner, enables direct injection of large aliquots of raw extracts (resulting in a low detection limit), avoids contamination of the sample during preparation and is fully automated. This review starts with an overview of the technology, particularly the fundamentals of introducing large volumes of solvent into GC, and their implementation into various transfer techniques. The main part deals with the concepts of MOSH and MOAH analysis, with a thorough discussion of the choices made. It is followed by a description of the method. Finally auxiliary tools are summarized to remove interfering components, enrich the sample in case of a high fat content and obtain additional information about the MOSH and MOAH composition. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Alkaloids Profiling of Fumaria capreolata by Analytical Platforms Based on the Hyphenation of Gas Chromatography and Liquid Chromatography with Quadrupole-Time-of-Flight Mass Spectrometry

    Science.gov (United States)

    Bribi, Noureddine; Gómez-Caravaca, Ana María

    2017-01-01

    Two analytical platforms, gas chromatography (GC) coupled to quadrupole-time-of-flight (QTOF) mass spectrometry (MS) and reversed-phase ultrahigh performance liquid chromatography (UHPLC) coupled to diode array (DAD) and QTOF detection, were applied in order to study the alkaloid profile of Fumaria capreolata. The use of these mass analyzers enabled tentatively identifying the alkaloids by matching their accurate mass signals and suggested molecular formulae with those previously reported in libraries and databases. Moreover, the proposed structures were corroborated by studying their fragmentation pattern obtained by both platforms. In this way, 8 and 26 isoquinoline alkaloids were characterized using GC-QTOF-MS and RP-UHPLC-DAD-QTOF-MS, respectively, and they belonged to the following subclasses: protoberberine, protopine, aporphine, benzophenanthridine, spirobenzylisoquinoline, morphinandienone, and benzylisoquinoline. Moreover, the latter analytical method was selected to determine at 280 nm the concentration of protopine (9.6 ± 0.7 mg/g), a potential active compound of the extract. In conclusion, although GC-MS has been commonly used for the analysis of this type of phytochemicals, RP-UHPLC-DAD-QTOF-MS provided essential complementary information. This analytical method can be applied for the quality control of phytopharmaceuticals containing Fumaria extracts currently found in the market. PMID:29348751

  3. Urinary metabonomics study in a rat model in response to protein-energy malnutrition by using gas chromatography-mass spectrometry and liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Wu, Zeming; Li, Min; Zhao, Chunxia; Zhou, Jia; Chang, Yuwei; Li, Xiang; Gao, Peng; Lu, Xin; Li, Yousheng; Xu, Guowang

    2010-11-01

    Systematic studies were performed on the biological perturbations in metabolic phenotype responding to protein-energy malnutrition through global metabolic profiling analysis, in combination with pattern recognition. The malnutrition rat model was established through five weeks of strict diet restriction, and the metabonome data obtained from gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-mass spectrometry (LC-MS) were integrated to approximate the comprehensive metabolic signature. Principal component analysis and orthogonal projection to latent structure analysis were used for the classification of metabolic phenotypes and discovery of differentiating metabolites. The perturbations in the urine profiles of malnourished rats were marked by higher levels of creatine, threitol, pyroglutamic acid, gluconic acid and kynurenic acid, as well as decreased levels of succinic acid, cis-aconitic acid, citric acid, isocitric acid, threonic acid, trimethylglycine, N-methylnicotinic acid and uric acid. The alterations in these metabolites were associated with perturbations in energy metabolism, carbohydrate, amino acid, and fatty acid metabolism, purine metabolism, cofactor and vitamin metabolism, in response to protein and energy malnutrition. Our findings show the integration of GC-MS and LC-MS techniques for untargeted metabolic profiling analysis was promising for nutriology.

  4. [The study of vapor-liquid equilibria for polymer/solvents by using gas-liquid chromatography].

    Science.gov (United States)

    Xie, J

    1999-05-01

    The infinite dilution weight fraction activity coefficient, omega 1 infinity, and Flory-Huggins interaction parameter, chi, have been determined for systems of polydimethylsiloxane (PDMS)/solvents and polymethyl-methacrylate (PMMA)/solvents by using gas chromatography from 58 degrees C to 180 degrees C. The solvents include styrene, acetone, ethyl ether, methanol, ethanol, acetic acid, trichloromethane, tetrahydrofuran and ethyl acetate in PDMS/solvent systems and n-hexane, n-heptane, cyclohexane, benzene, toluene, ethyl benzene, styrene, acetone, ethyl ether, methanol, ethanol, methyl methacrylate(MMA), trichloromethane, tetrahydrofuran and ethyl acetate in the PMMA/solvent systems. The results showed that omega 1 infinity and chi were decreased with the increase of temperature in the range from 58 degrees C to 180 degrees C. The study showed that UNIFAC and UNIFAC-FV models could not all be used to estimate omega 1 infinity of the solvents in PMMA/solvent systems. Therefore, UNIFAC and UNIFAC-FV models must be corrected or other models must be used.

  5. Extension of Toth function from gas-solid to liquid-solid equilibria and application to reversed-phase liquid chromatography systems

    Energy Technology Data Exchange (ETDEWEB)

    Gritti, Fabrice [University of Tennessee, Knoxville (UTK); Guiochon, Georges A [ORNL

    2006-03-01

    The extension of the {Psi} function developed by Toth from equilibria taking place at gas-solid interfaces to those taking place at liquid-solid interfaces was investigated. The results were applied to conventional liquid-solid systems used in reversed-phase liquid chromatography (RPLC). The adsorbents in these systems are made of porous silica having a hydrophobic solid surface obtained by chemically bonding C{sub 18} alkyl chains to a porous silica gel then endcapping the surface with trimethylsilyl groups. The liquid is an aqueous solution of an organic solvent, most often methanol or acetonitrile. The probe compound used here is phenol. Adsorption data of phenol were measured using the dynamic frontal analysis (FA) method. The excess adsorption of the organic solvent was measured using the minor disturbance (MD) method. Activity coefficients in the bulk were estimated through the UNIFAC group contributions. The results show that the {Psi} function predicts 90% of the total free energy of immersion, {Delta}F, of the solid when the concentration of phenol is moderate (typically less than 10 g/L). At higher concentrations, the nonideal behavior of the bulk liquid phase becomes significant and it may contribute up to about 30% of {Delta}F. The high concentration of adsorbed molecules of phenol at the interface decreases the interfacial tension, {sigma}, by about 18 mN/m, independently of the structure of the adsorbed phase and of the nature of the organic solvent.

  6. Extension of Tóth Psi function from gas-solid to liquid-solid equilibria and application to reversed-phase liquid chromatography systems.

    Science.gov (United States)

    Gritti, Fabrice; Guiochon, Georges

    2006-07-01

    The extension of the Psi function developed by Tóth from equilibria taking place at gas-solid interfaces to those taking place at liquid-solid interfaces was investigated. The results were applied to conventional liquid-solid systems used in reversed-phase liquid chromatography (RPLC). The adsorbents in these systems are made of porous silica having a hydrophobic solid surface obtained by chemically bonding C(18) alkyl chains to a porous silica gel then endcapping the surface with trimethylsilyl groups. The liquid is an aqueous solution of an organic solvent, most often methanol or acetonitrile. The probe compound used here is phenol. Adsorption data of phenol were measured using the dynamic frontal analysis (FA) method. The excess adsorption of the organic solvent was measured using the minor disturbance (MD) method. Activity coefficients in the bulk were estimated through the UNIFAC group contributions. The results show that the Psi function predicts 90% of the total free energy of immersion, DeltaF, of the solid when the concentration of phenol is moderate (typically less than 10 g/L). At higher concentrations, the nonideal behavior of the bulk liquid phase becomes significant and it may contribute up to about 30% of DeltaF. The high concentration of adsorbed molecules of phenol at the interface decreases the interfacial tension, sigma, by about 18 mN/m, independently of the structure of the adsorbed phase and of the nature of the organic solvent.

  7. Variability of matrix effects in liquid and gas chromatography - mass spectrometry analysis of pesticide residues after QuEChERS sample preparation of different food crops

    Science.gov (United States)

    Gas and liquid chromatography (GC and LC) coupled to sophisticated mass spectrometry (MS) instruments are among the most powerful analytical tools currently available to monitor pesticide residues in food, among other applications. However, both GC-MS and LC-MS are susceptible to matrix effects whi...

  8. Factors That Contribute to Assay Variation in Quantitative Analysis of Sex Steroid Hormones Using Liquid and Gas Chromatography-Mass Spectrometry

    Science.gov (United States)

    Xu, Xia; Veenstra, Timothy D.

    2012-01-01

    The list of physiological events in which sex steroids play a role continues to increase. To decipher the roles that sex steroids play in any condition requires high quality cohorts of samples and assays that provide highly accurate quantitative measures. Liquid and gas chromatography coupled with mass spectrometry (LC-MS and GC-MS) have…

  9. Monolithic column in gas chromatography.

    Science.gov (United States)

    Kurganov, A

    2013-05-02

    Monolithic columns invented in chromatographic praxis almost 40 years ago gained nowadays a lot of popularity in separations by liquid chromatographic technique. At the same time, application of monolithic columns in gas chromatography is less common and only a single review published by Svec et al. covers this field of research. Since that time a lot of new findings on application and properties of monolithic columns in gas chromatography have been published in the literature deserving consideration and discussion. This review considers preparation of monolithic columns for GC, an impact of preparation conditions on column performance, optimization of separation conditions for GC analysis on monolithic columns and other important aspects of preparation and usage of monolithic capillary columns in GC. A final part of the review discusses the modern trends and possible applications in the future of capillary monolithic columns in GC. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Liquid-phase microextraction combined with hollow fiber as a sample preparation technique prior to gas chromatography/mass spectrometry.

    Science.gov (United States)

    Zhao, Limian; Lee, Hian Kee

    2002-06-01

    Two modes of liquid-phase microextraction (LPME) combined with hollow fiber (HF) were developed for gas chromatography/mass spectrometry (GC/MS). Both methodologies, that is, static LPME with HF and dynamic LPME with HF, involved the use of a small volume of organic solvent impregnated in the hollow fiber, which was held by the needle of a conventional GC syringe. In static LPME/HF, the hollow fiber impregnated with solvent was immersed in the aqueous sample, and the extraction processed under stirring; in dynamic LPME/HF, the solvent was repeatedly withdrawn into and discharged from the hollow fiber by a syringe pump. This is believed to be the first reported instance of a semiautomated liquid microextraction procedure. The performance of the two techniques was demonstrated in the analysis of two PAH compounds in an aqueous sample. Static LPME/HF provided approximately 35-fold enrichment in 10 min and good reproducibility (approximately 4%). Dynamic LPME/HF could provide higher enrichment (approximately 75-fold) in 10 min and even better reproducibility (approximately 3%). Both methods allow the direct transfer of extracted analytes to a GC/MS system for analysis.

  11. Determination of atranol and chloroatranol in perfumes using simultaneous derivatization and dispersive liquid-liquid microextraction followed by gas chromatography-mass spectrometry.

    Science.gov (United States)

    López-Nogueroles, Marina; Chisvert, Alberto; Salvador, Amparo

    2014-05-15

    A new analytical method based on simultaneous derivatization and dispersive liquid-liquid microextraction (DLLME) followed by gas chromatography-mass spectrometry (GC-MS), for the determination of the allergenic compounds atranol and chloroatranol in perfumes, is presented. Derivatization of the target analytes by means of acetylation with anhydride acetic in carbonate buffer was carried out. Thereby volatility and detectability were increased for improved GC-MS sensitivity. In addition, extractability by DLLME was also enhanced due to a less polar character of the solutes. A liquid-liquid extraction was performed before DLLME to clean up the sample and to obtain an aqueous sample solution, free of the low polar matrix from the essential oils, as donor phase. Different parameters, such as the nature and volume of both the extraction and disperser solvents, the ionic strength of the aqueous donor phase or the effect of the derivatization reagent volume, were optimized. Under the selected conditions (injection of a mixture of 750μL of acetone as disperser solvent, 100μL of chloroform as extraction solvent and 100μL of anhydride acetic as derivatization reagent) the figures of merit of the proposed method were evaluated. Limits of detection in the low ngmL(-1) range were obtained. Matrix effect was observed in real perfume samples and thus, standard addition calibration is recommended. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Comparison of gas chromatography/isotope ratio mass spectrometry and liquid chromatography/isotope ratio mass spectrometry for carbon stable-isotope analysis of carbohydrates.

    Science.gov (United States)

    Moerdijk-Poortvliet, Tanja C W; Schierbeek, Henk; Houtekamer, Marco; van Engeland, Tom; Derrien, Delphine; Stal, Lucas J; Boschker, Henricus T S

    2015-07-15

    We compared gas chromatography/isotope ratio mass spectrometry (GC/IRMS) and liquid chromatography/isotope ratio mass spectrometry (LC/IRMS) for the measurement of δ(13)C values in carbohydrates. Contrary to GC/IRMS, no derivatisation is needed for LC/IRMS analysis of carbohydrates. Hence, although LC/IRMS is expected to be more accurate and precise, no direct comparison has been reported. GC/IRMS with the aldonitrile penta-acetate (ANPA) derivatisation method was compared with LC/IRMS without derivatisation. A large number of glucose standards and a variety of natural samples were analysed for five neutral carbohydrates at natural abundance as well as at (13)C-enriched levels. Gas chromatography/chemical ionisation mass spectrometry (GC/CIMS) was applied to check for incomplete derivatisation of the carbohydrate, which would impair the accuracy of the GC/IRMS method. The LC/IRMS technique provided excellent precision (±0.08‰ and ±3.1‰ at natural abundance and enrichment levels, respectively) for the glucose standards and this technique proved to be superior to GC/IRMS (±0.62‰ and ±19.8‰ at natural abundance and enrichment levels, respectively). For GC/IRMS measurements the derivatisation correction and the conversion of carbohydrates into CO2 had a considerable effect on the measured δ(13)C values. However, we did not find any significant differences in the accuracy of the two techniques over the full range of natural δ(13)C abundances and (13)C-labelled glucose. The difference in the performance of GC/IRMS and LC/IRMS diminished when the δ(13)C values were measured in natural samples, because the chromatographic performance and background correction became critical factors, particularly for LC/IRMS. The derivatisation of carbohydrates for the GC/IRMS method was complete. Although both LC/IRMS and GC/IRMS are reliable techniques for compound-specific stable carbon isotope analysis of carbohydrates (provided that derivatisation is complete and the

  13. Update of on-line coupled liquid chromatography - gas chromatography for the analysis of mineral oil hydrocarbons in foods and cosmetics.

    Science.gov (United States)

    Biedermann, Maurus; Munoz, Celine; Grob, Koni

    2017-10-27

    On-line coupled high performance liquid chromatography-gas chromatography-flame ionization detection (HPLC-GC-FID) is the most widely used method for the analysis of mineral oil hydrocarbons in food, food contact materials, tissues and cosmetics. With comprehensive two-dimensional gas chromatography (GCxGC), a tool became available for better establishing the elution sequence of the various types of hydrocarbons from the HPLC column used for isolating the mineral oil saturated hydrocarbons (MOSH) and mineral oil aromatic hydrocarbons (MOAH). The performance of a heavily used HPLC column with reduced retention for MOAH was investigated to improve the robustness of the method. Updates are recommended that render the MOSH/MOAH separation less dependent of the state of the HPLC column and more correct in cases of highly refined mineral oil products of high molecular mass. Cyclohexyl cyclohexane (Cycy), used as internal standard, turned out to be eluted slightly after cholestane (Cho); apparently the size exclusion effect predominates the extra retention by ring number on the 60Å pore size silica gel. Hence, Cycy can be used to determine the end of the MOSH fraction. Long chain alkyl benzenes were eluted earlier than tri-tert. butyl benzene (Tbb). It is proposed to start the MOAH transfer immediately after the MOSH fraction and use a gradient causing breakthrough of dichloromethane (visible in the UV chromatogram) at a time suitable to elute perylene (Per) at the end of the fraction. In this way, a decrease in retention power of the HPLC column can be tolerated without adjustment of the MOAH fraction until some MOAH start being eluted into the MOSH fraction. This critical point can be checked either with di(2-ethylhexyl) benzene (DEHB) as a marker or the HPLC-UV chromatogram. Finally, based on new findings in rats and human tissues, it is recommended to integrate the MOSH and MOAH up to the retention time of the n-alkane C40. Copyright © 2017 Elsevier B.V. All rights

  14. Analysis of particulate polycyclic aromatic hydrocarbons by on-line coupled supercritical fluid extraction-liquid chromatography-gas chromatography-mass spectrometry

    Science.gov (United States)

    Shimmo, Masahiko; Adler, Heidi; Hyötyläinen, Tuulia; Hartonen, Kari; Kulmala, Markku; Riekkola, Marja-Liisa

    An on-line supercritical fluid extraction-liquid chromatography-gas chromatography-mass spectrometry (SFE-LC-GC-MS) method was developed for the analysis of the particulate polycyclic aromatic hydrocarbons (PAHs). The limits of detection of the system for the quantification standards were in the range of 0.25-0.57 ng, while the limits of determinations for filter samples varied from 0.02 to 0.04 ng m -3 (24 h sampling). The linearity was excellent from 5 to 300 ng ( R2>0.967). The analysis could be carried out in a closed system without tedious manual sample pretreatment and with no risk of errors by contamination or loss of the analytes. The results of the SFE-LC-GC-MS method were comparable with those for Soxhlet and shake-flask extractions with GC-MS. The new method was applied to the analysis of PAHs collected by high-volume filter in the Helsinki area to study the seasonal trend of the concentrations. The individual PAH concentrations varied from 0.015 to more than 1 ng m -3, while total PAH concentrations varied from 0.81 to 5.68 ng m -3. The concentrations were generally higher in winter than in summer. The mass percentage of the total PAHs in total suspended particulates ranged from 2.85×10 -3% in July to 15.0×10 -3% in December. Increased emissions in winter, meteorological conditions, and more serious artefacts during the sampling in summer season may explain the concentration profiles.

  15. Advancing liquid/liquid extraction through a novel microfluidic device: Theory, instrumentation and applications in gas chromatography

    NARCIS (Netherlands)

    Peroni, D.; van Egmond, W.; Kok, W.T.; Janssen, J.G.M.

    2012-01-01

    A new chip-based liquid-liquid extraction technique for sample preparation of aqueous samples for GC was developed. Extraction is performed in a segmented flow system with additional mixing provided by an etched channel structure. The dimensions of the device are optimized to allow benefiting of the

  16. Inverse gas chromatography - a different approach to characterization of solids and liquids:

    OpenAIRE

    Kunaver, Matjaž; Planinšek, Odon; Srčič, Stanko; Zadnik, Jernej

    2004-01-01

    IGC has become powerful technique in evaluating the properties of solids and liquids. It provides access to several physico-chemical properties of such materials including their surface energy, phase transitions, crystallinity andacid-base characteristics. Kinetic parameters such as diffusion coefficients can be determined. IGC is used to characterize a wide range of product types including pharmaceuticals, natural and synthetic polymers, food ingredients and products, minerals etc.

  17. Determination of polycyclic aromatic hydrocarbons in fresh milk by hollow fiber liquid-phase microextraction-gas chromatography mass spectrometry.

    Science.gov (United States)

    Sanagi, Mohd Marsin; Loh, Saw Hong; Wan Ibrahim, Wan Aini; Hasan, Mohamed Noor; Aboul Enein, Hassan Y

    2013-02-01

    In this work, a two-phase hollow fiber liquid-phase microextraction (HF-LPME) method combined with gas chromatography-mass spectrometry (GC-MS) is developed to provide a rapid, selective and sensitive analytical method to determine polycyclic aromatic hydrocarbons (PAHs) in fresh milk. The standard addition method is used to construct calibration curves and to determine the residue levels for the target analytes, fluorene, phenanthrene, fluoranthene, pyrene and benzo[a]pyrene, thus eliminating sample pre-treatment steps such as pH adjustment. The HF-LPME method shows dynamic linearity from 5 to 500 µg/L for all target analytes with R(2) ranging from 0.9978 to 0.9999. Under optimized conditions, the established detection limits range from 0.07 to 1.4 µg/L based on a signal-to-noise ratio of 3:1. Average relative recoveries for the determination of PAHs studied at 100 µg/L spiking levels are in the range of 85 to 110%. The relative recoveries are slightly higher than those obtained by conventional solvent extraction, which requires saponification steps for fluorene and phenanthrene, which are more volatile and heat sensitive. The HF-LPME method proves to be simple and rapid, and requires minimal amounts of organic solvent that supports green analysis.

  18. Hollow fiber-liquid phase microextraction combined with gas chromatography for the determination of phenothiazine drugs in urine.

    Science.gov (United States)

    Xiao, Qin; Hu, Bin

    2010-06-01

    A simple method of hollow fiber-liquid phase microextraction (HF-LPME) combined with gas chromatography (GC) was developed for the analysis of four phenothiazine drugs (promethazine, promazine, chlorpromazine and trifluoperazine) in human urine samples. All variables affecting the extraction of target analytes including organic solvent type, stirring rate, extraction time, extraction temperature, pH of sample solution and ionic strength were carefully studied and optimized. Under the optimal conditions, the analytical performance of HF-LPME-GC-flame photometric detector (FPD) and HF-LPME-GC-flame ionization detector (FID) were evaluated and compared. The results showed that the HF-LPME-GC-FID was more sensitive than HF-LPME-GC-FPD for the determination of four target phenothiazine drugs, while the signal peak shape and resolution obtained by HF-LPME-GC-FPD was better than that obtained by HF-LPME-GC-FID. HF-LPME-GC-FPD/FID was successfully applied for the assay of the interested phenothiazine drugs in urine sample, and the excretion of the drugs was also investigated by monitoring the variation of the concentration of chlorpromazine in urine of a psychopath within 8 h after drug-taking. The proposed method provided an effective and fast way for the therapeutic drug monitoring (TDM) of phenothiazine. Copyright 2010 Elsevier B.V. All rights reserved.

  19. Validation of Analysis Method of pesticides in fresh tomatoes by Gas Chromatography associated to a liquid scintillation counting

    International Nuclear Information System (INIS)

    Dhib, Ahlem

    2011-01-01

    Pesticides are nowadays considered as toxic for human health. The maximum residues levels (MRL) in foodstuff are more and more strict. Therefore, selective analytical techniques are necessary for their identification and their quantification. The aim of this study is to set up a multi residue method for the determination of pesticides in tomatoes by gas chromatography with μECD detector (GC/μECD) associated to liquid scintillation counting. A global analytical protocol consisting of a QuECHERS version of the extraction step followed by purification step of the resulting extract on a polymeric sorbent was set up. The 14 C-chloropyrifos used as an internal standard proved excellent to control the different steps needed for the sample preparation. The method optimized is specific, selective with a recovery averaged more than 70 pour cent, repetitive and reproducible. Although some others criteria need to be checked regarding validation before its use in routine analysis, the potential of the method has been demonstrated.

  20. Headspace Hanging Drop Liquid Phase Microextraction and Gas Chromatography-Mass Spectrometry for the Analysis of Flavors from Clove Buds

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Mi Jin; Shin, Yeon Jae; Oh, Se Yeon; Kim, Nam Sun; Kim, Kun; Lee, Dong Sun [Seoul Women' s University, Seoul (Korea, Republic of)

    2006-02-15

    A novel sample pretreatment technique, headspace hanging drop liquid phase microextraction (HS-LPME) was studied and applied to the determination of flavors from solid clove buds by gas chromatography-mass spectrometry (GC-MS). Several parameters affecting on HS-LPME such as organic solvent drop volume, extraction time, extraction temperature and phase ratio were investigated. 1-Octanol was selected as the extracting solvent, drop size was fixed to 0.6 μL. 60 min extraction time at 25 .deg. C was chosen. HS-LPME has the good efficiency demonstrated by the higher partition equilibrium constant (K{sub lh}) values and concentration factor (CF) values. The limits of detection (LOD) were 1.5-3.2 ng. The amounts of eugenol, β-caryophyllene and eugenol acetate from the clove bud sample were 1.90 mg/g, 1.47 mg/g and 7.0 mg/g, respectively. This hanging drop based method is a simple, fast and easy sample enrichment technique using minimal solvent. HSLPME is an alternative sample preparation method for the analysis of volatile aroma compounds by GC-MS.

  1. Introduction to modern liquid chromatography

    National Research Council Canada - National Science Library

    Snyder, Lloyd R; Kirkland, J. J; Dolan, John W

    2010-01-01

    "High-performance liquid chromatography (HPLC) is today the leading technique for chemical analysis and related applications, with an ability to separate, analyze, and/or purify virtually any sample...

  2. Application of gas-liquid chromatography and high-performance liquid chromatography to the analysis of trace amounts of salicylic acid, acetylsalicylic anhydride and acetylsalicylsalicylic acid in aspirin samples and aspirin formulations.

    Science.gov (United States)

    Ali, S L

    1976-11-03

    The gas-liquid chromatographic (GLC) determination of salicylic acid (SA) in 12 commercial acetylsalicylic acid (aspirin, ASA) samples and 12 ASA formulations is reported. The GLC determination of SA as an impurity in ASA, utilising methylation with methyl iodide in the presence of potassium carbonate, requires a column chromatographic separation of SA prior to derivatization. Trace amounts of SA in ASA have also been determined by high-performance liquid chromatography (HPLC) on a Sil-X-I adsorption column using light petroleum-ethyl acetate-acetic acid as the mobile phase. Acetylsalicylic anhydride (ASN) and acetylsalicylsalicylic acid (ASSA) were determined by HPLC on a reversed-phase C18 column with water-methanol mixtures as the mobile phase. GLC was also applied to the determination of ASN as an impurity in ASA formulations.

  3. Multiplex gas chromatography

    Science.gov (United States)

    Valentin, Jose R.

    1990-01-01

    The principles of the multiplex gas chromatography (GC) technique, which is a possible candidate for chemical analysis of planetary atmospheres, are discussed. Particular attention is given to the chemical modulators developed by present investigators for multiplex GC, namely, the thermal-desorption, thermal-decomposition, and catalytic modulators, as well as to mechanical modulators. The basic technique of multiplex GC using chemical modulators and a mechanical modulator is demonstrated. It is shown that, with the chemical modulators, only one gas stream consisting of the carrier in combination with the components is being analyzed, resulting in a simplified instrument that requires relatively few consumables. The mechanical modulator demonstrated a direct application of multiplex GC for the analysis of gases in atmosphere of Titan at very low pressures.

  4. Conventional and fast gas chromatography analysis of biodiesel blends using an ionic liquid stationary phase.

    Science.gov (United States)

    Ragonese, Carla; Tranchida, Peter Quinto; Sciarrone, Danilo; Mondello, Luigi

    2009-12-18

    The present research is focused on the GC-FID determination of fatty acid methyl esters (FAMEs) in diesel blends, by means of an ionic liquid stationary phase, characterized by a dicationic 1,9-di(3-vinyl-imidazolium)nonane bis(trifluoromethyl)sulfonylimidate structure (SLB-IL100). The high polarity of the ionic liquid stationary phase allowed the separation of the FAMEs, from the less-retained hydrocarbons, thus avoiding the requirement of a hydrocarbon LC pre-separation. The results derived from the analyses of a soybean FAMEs B20 sample, carried out on an SLB-IL100 conventional column (30 m x 0.25 mm i.d. x 0.20 mm d(f)), were compared with those attained on a polyethylene glycol column, of equivalent dimensions. Conventional and fast GC methods, for the analysis of FAMEs in diesel blends, were developed on an SLB-IL100 30 m x 0.25 mm i.d. x 0.20 microm d(f) and on an SLB-IL100 12 m x 0.10 mm i.d. x 0.08 microm d(f) column, respectively. The optimized IL methods were subjected to validation: retention time and peak area intra-day precision (n=5) were good, with CV % values lower than 0.08% and 4.9%, respectively. With regards to the quantitation of FAMEs in biodiesel blends, a five points calibration curve was constructed, using C(17:0) as internal standard.

  5. An optimized method for fatty acid analysis, including quantification of trans fatty acids, in human adipose tissue by gas-liquid chromatography

    DEFF Research Database (Denmark)

    Bysted, Anette; Cold, S; Hølmer, Gunhild Kofoed

    1999-01-01

    for 25 min, and finally raised at 25 degrees C/min to 225 degrees C. The trans and cis isomers of18:1 were well separated from each other, as shown by silver-ion thin-layer chromatography. Verification by standardsshowed that the trans 18:1 isomers with a double bond in position 12 or lower were......Considering the need for a quick direct method for measurement of the fatty acid composition including trans isomers ofhuman adipose tissue we have developed a procedure using gas-liquid chromatography (GLC) alone, which is thussuitable for validation of fatty acid status in epidemiological studies...

  6. Determination of polybrominated diphenyl ethers at trace levels in environmental waters using hollow-fiber microporous membrane liquid-liquid extraction and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Fontanals, Núria; Barri, Thaer; Bergström, Staffan; Jönsson, Jan-Ake

    2006-11-10

    In this study, we present a simple and easy-to-use extraction method that is based on a hollow-fiber microporous membrane liquid-liquid extraction (HF-MMLLE), as an extraction technique, followed by gas chromatography-mass spectrometry (GC-MS) to determine a group of brominated flame retardants (BFRs), polybrominated diphenyl ethers (PBDEs), at trace levels in aqueous samples. The hollow-fiber membrane (HF) filled with organic solvent was immersed into the aqueous sample, spiked with the analytes at ng l(-1) level, and stirred for 60 min. The proposed method could attain enrichment factors (E(e)) up to 5200 times, after optimising parameters, such as organic solvent, stirring speed and extraction time, that affect the extraction. The HF-MMLLE-GC-MS method was successfully applied to the extraction of PBDEs from tap, river and leachate water samples with spike recoveries ranging from 85% to 110%. The method validation with reagent and leachate water samples provided good linearity, detection limits of 1.1 ng l(-1) or lower, both in reagent and leachate water, as well as satisfactory precision in terms of repeatability and reproducibility with values of % relative standard deviation (%RSD) lower than 8.6 and 16.9, respectively.

  7. Determination of Wastewater Compounds in Whole Water by Continuous Liquid-Liquid Extraction and Capillary-Column Gas Chromatography/Mass Spectrometry

    Science.gov (United States)

    Zaugg, Steven D.; Smith, Steven G.; Schroeder, Michael P.

    2006-01-01

    A method for the determination of 69 compounds typically found in domestic and industrial wastewater is described. The method was developed in response to increasing concern over the impact of endocrine-disrupting chemicals on aquatic organisms in wastewater. This method also is useful for evaluating the effects of combined sanitary and storm-sewer overflow on the water quality of urban streams. The method focuses on the determination of compounds that are indicators of wastewater or have endocrine-disrupting potential. These compounds include the alkylphenol ethoxylate nonionic surfactants, food additives, fragrances, antioxidants, flame retardants, plasticizers, industrial solvents, disinfectants, fecal sterols, polycyclic aromatic hydrocarbons, and high-use domestic pesticides. Wastewater compounds in whole-water samples were extracted using continuous liquid-liquid extractors and methylene chloride solvent, and then determined by capillary-column gas chromatography/mass spectrometry. Recoveries in reagent-water samples fortified at 0.5 microgram per liter averaged 72 percent ? 8 percent relative standard deviation. The concentration of 21 compounds is always reported as estimated because method recovery was less than 60 percent, variability was greater than 25 percent relative standard deviation, or standard reference compounds were prepared from technical mixtures. Initial method detection limits averaged 0.18 microgram per liter. Samples were preserved by adding 60 grams of sodium chloride and stored at 4 degrees Celsius. The laboratory established a sample holding-time limit prior to sample extraction of 14 days from the date of collection.

  8. Method for the simultaneous determination of monoaromatic and polycyclic aromatic hydrocarbons in industrial effluents using dispersive liquid-liquid microextraction with gas chromatography-mass spectrometry.

    Science.gov (United States)

    Makoś, Patrycja; Fernandes, André; Boczkaj, Grzegorz

    2018-02-23

    We present a new method for simultaneous determination of 22 monoaromatic and polycyclic aromatic hydrocarbons in postoxidative effluents from the production of petroleum bitumen using dispersive liquid-liquid microextraction coupled to gas chromatography and mass spectrometry. The eight extraction parameters including the type and volume of extraction and disperser solvent, pH, salting out effect, extraction, and centrifugation time were optimized. The low detection limit ranging from 0.36 to 28 μg/L, limit of quantitation (1.1-84 μg/L), good reproducibility, and wide linear ranges, as well as the recoveries ranging from 71.74 to 114.67% revealed that the new method allows the determination of aromatic hydrocarbons at low concentration levels in industrial effluents having a very complex composition. The developed method was applied to the determination of content of mono- and polycyclic aromatic hydrocarbons in samples of raw postoxidative effluents in which 15 compounds were identified at concentrations ranging from 1.21 to 1017.0 μg/L as well as in effluents after chemical treatment. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Determination of UV filters in both soluble and particulate fractions of seawaters by dispersive liquid-liquid microextraction followed by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Benedé, J L; Chisvert, A; Salvador, A; Sánchez-Quiles, D; Tovar-Sánchez, A

    2014-02-17

    An analytical method to determine the total content (i.e., not only in the soluble fraction but also in the particulate one) of eight commonly used UV filters in seawater samples is presented for the first time. Dispersive liquid-liquid microextraction (DLLME) is used as microextraction technique to pre-concentrate the target analytes before their determination by gas chromatography-mass spectrometry (GC-MS). In order to release the UV filters from the suspended particles an ultrasound treatment is performed before DLLME. The ultrasound treatment time was studied in order to achieve a quantitative lixiviation of the target analytes. The type and volume of both disperser and extraction solvent, the sample volume, the pH and the ionic strength involved in the DLLME have been optimized to provide the best enrichment factors. Under the optimized conditions, the method was successfully validated showing good linearity, enrichment factors between 112 and 263 depending on the analyte, limits of detection and quantification in the low ng L(-1) range (10-30 ng L(-1) and 33-99 ng L(-1), respectively) and good intra- and inter-day repeatability (RSD UV filters in the particulate fraction that would have been ignored if only the soluble fraction had been considered. This fact shows that the UV filters are also accumulated in the suspended particles contained in water, what should be taken into account from an environmental standpoint. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Determination of triazole pesticide residues in edible oils using air-assisted liquid-liquid microextraction followed by gas chromatography with flame ionization detection.

    Science.gov (United States)

    Farajzadeh, Mir Ali; Feriduni, Behruz; Mogaddam, Mohammad Reza Afshar

    2015-03-01

    In the present study, a rapid, simple, and highly efficient sample preparation method based on air-assisted liquid-liquid microextraction followed by gas chromatography with flame ionization detection was developed for the extraction, preconcentration, and determination of five triazole pesticides (penconazole, hexaconazole, diniconazole, tebuconazole, and triticonazole) in edible oils. Initially, the oil samples were diluted with hexane and a few microliter of a less soluble organic solvent (extraction solvent) in hexane was added. To form fine and dispersed extraction solvent droplets, the mixture of oil sample solution and extraction solvent is repeatedly aspirated and dispersed with a syringe. Under the optimum extraction conditions, the method showed low limits of detection and quantification between 2.2-6.1 and 7.3-20 μg/L, respectively. Enrichment factors and extraction recoveries were in the ranges of 71-96 and 71-96%, respectively. The relative standard deviations for the extraction of 100 and 250 μg/L of each pesticide were less than 5% for intraday (n = 6) and interday (n = 3) precisions. Finally edible oil samples were successfully analyzed using the proposed method, and hexaconazole was found in grape seed oil. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Ultrasonic nebulization extraction assisted dispersive liquid-liquid microextraction followed by gas chromatography for the simultaneous determination of six parabens in cosmetic products.

    Science.gov (United States)

    Wei, Hongmin; Yang, Jinjuan; Zhang, Hanqi; Shi, Yuhua

    2014-09-01

    A simple, rapid, and efficient method of ultrasonic nebulization extraction assisted dispersive liquid-liquid microextraction was developed for the simultaneous determination of six parabens in cosmetic products. The analysis was carried out by gas chromatography. Water was used as the dispersive solvent instead of traditional organic disperser. The experimental factors affecting the extraction yield, such as the extraction solvent and volume, extraction time, dispersive solvent and volume, ionic strength, and centrifuging condition were studied and optimized in detail. The limit of detections for the target analytes were in the range of 2.0-9.5 μg/g. Good linear ranges were obtained with the coefficients ranging from 0.9934 to 0.9969. The proposed method was successfully applied to the analysis of six parabens in 16 cosmetic products. The recoveries of the target analytes in real samples ranged from 81.9 to 108.7%, and the relative standard deviations were <5.3%. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Determination of bile acids in serum by capillary gas-liquid chromatography.

    Science.gov (United States)

    Karlaganis, G; Paumgartner, G

    1979-02-15

    A glass capillary column and an appropriate relatively simple procedure for sample preparation have been developed for determination of serum bile acids. Sample preparation involved extraction with Amberlite XAD-2, solvolysis of sulfates, enzymatic hydrolysis with cholylglycine hydrolase, methylation and silylation. Because of complete chromatographic separation of bile acid trimethylsilylether derivatives from cholesterol on the capillary column, an additional step for elimination of cholesterol could be omitted. Trimethylsilylether derivatives were separated on a 20 meter x 0.3 mm i.d. glass capillary column covered with a crystal layer of barium carbonate and coated with polyethyleneglycol 20,000 as liquid phase according to Grob, K. and Grob, G. (1976) J. Chromatogr.125, 471--485, and Grob, K., Grob, G. and Grob, Jr., K., (1977) Chromatographia 10, 181--187. Overall recovery of the major human conjugated bile acids ranged from 86 to 89%. Reproducibility of bile acid determination was satisfactory in both normal and pathological serum with elevated bile acid concentrations (coefficient of variation 7.6 to 10.0%). The mean concentrations of cholic, deoxycholic, chenodeoxycholic and lithocholic acid in the serum of healthy subjects were 0.9, 1.0, 1.7 and 0.2 mumol/l in males, and 1.0, 0.8, 1.4 and 0.2 mumol/l in females.

  13. Analysis of Long-Chain Unsaturated Fatty Acids by Ionic Liquid Gas Chromatography.

    Science.gov (United States)

    Weatherly, Choyce A; Zhang, Ying; Smuts, Jonathan P; Fan, Hui; Xu, Chengdong; Schug, Kevin A; Lang, John C; Armstrong, Daniel W

    2016-02-17

    Four ionic liquid (IL) columns, SLB-IL59, SLB-IL60, SLB-IL65, and SLB-IL111, were evaluated for more rapid analysis or improved resolution of long-chain methyl and ethyl esters of omega-3, omega-6, and additional positional isomeric and stereoisomeric blends of fatty acids found in fish oil, flaxseed oil, and potentially more complicated compositions. The three structurally distinct IL columns provided shorter retention times and more symmetric peak shapes for the fatty acid methyl or ethyl esters than a conventional polyethylene glycol column (PEG), resolving cis- and trans-fatty acid isomers that coeluted on the PEG column. The potential for improved resolution of fatty acid esters is important for complex food and supplement applications, where different forms of fatty acid can be incorporated. Vacuum ultraviolet detection contributed to further resolution for intricate mixtures containing cis- and trans-isomers, as exemplified in a fatty acid blend of shorter chain C18:1 esters with longer chain polyunsaturated fatty acid (PUFA) esters.

  14. Automation and optimization of liquid-phase microextraction by gas chromatography.

    Science.gov (United States)

    Ouyang, Gangfeng; Zhao, Wennan; Pawliszyn, Janusz

    2007-01-05

    Several fully automated liquid-phase microextraction (LPME) techniques, including static headspace LPME (HS-LPME) (a drop of solvent is suspended at the tip of a microsyringe needle and exposed to the headspace of the sample solution), exposed dynamic HS-LPME (the solvent is exposed in the headspace of sample vial for different time, and then withdrawn into the barrel of the syringe. This procedure is repeated a number of times), unexposed dynamic HS-LPME (the solvent is moved inside the needle and the barrel of a syringe, and the gaseous sample is withdrawn into the barrel and then ejected), static direct-immersed LPME (DI-LPME) (a drop of solvent is suspended at the tip of a microsyringe needle and directly immersed into the sample solution), dynamic DI-LPME (the solvent is moved inside the needle and the barrel of a syringe, and the sample solution is withdrawn and ejected), and two phase hollow fiber-protected LPME (HF-LPME) (a hollow fiber is used to stabilize and protect the solvent), auto-performed with a commercial CTC CombiPal autosampler, are described in this paper. Critical experimental factors, including temperature, choice of extraction solvent, solvent volume, plunger movement rate, and extraction time were investigated. Among the three HS-LPME techniques that were evaluated, the exposed dynamic HS-LPME technique provided the best performance, compared to the unexposed dynamic HS-LPME and static HS-LPME approaches. For DI-LPME, the dynamic process can enhance the extraction efficiency and the achieved method precision is comparable with the static DI-LPME technique. The precision of the fully automated HF-LPME is quite acceptable (RSD values below 6.8%), and the concentration enrichment factors are better than the DI-LPME approaches. The fully automated LPME techniques are more accurate and more convenient, and the reproducibility achieved eliminates the need for an internal standard to improve the method precision.

  15. Characterization of volatile components in dry chrysanthemum flowers using headspace-liquid-phase microextraction-gas chromatography.

    Science.gov (United States)

    Wang, Guoqing; Dong, Chunhong; Sun, Yu-an; Xie, Kui; Zheng, Haiyu

    2008-02-01

    A headspace-liquid-phase microextraction (HS-LPME)-GC (gas chromatography) method for the characterization of volatile components in dry chrysanthemum flowers has been developed. In the proposed method, two extraction solvents, n-hexadecane and benzyl alcohol, are used for preconcentrating volatiles in the sample. A droplet of the extraction solvent is squeezed from the GC syringe and inserted in the headspace of the sample bottle with the dry flower, immersed in deionized water, and warmed in a water bath. The optimum HS-LPME parameters in terms of extraction solvent type, droplet magnitude, equilibrium (water bath) temperature, equilibrium time, extraction time, and ionic strength are achieved using GC-FID (flame ionization detection) by varying several levels of the factors that affect the HS-LPME procedure. After extraction under the optimized conditions, the extraction droplet is retracted into the syringe and injected for GC-MS (mass spectrometry) analysis. Thirty-three volatile components are extracted and identified using this HS-LPME-GC-MS method, with the aid of chemometric methods. It is shown that the volatiles in dry chrysanthemum flowers are mainly unsaturated organic compounds, such as monoterpenes, sesquiterpenes and their oxygenous derivatives, triterpenoids, and aliphatic compounds. Several representative components, in order of precedence of the retention time, are pinene (106.3 microg/g), camphene (112.7 microg/g), eucapyptol (52.1 microg/g), camphor (29.4 microg/g), borneol (4.2 microg g), bornyl acetate (67.3 microg/g), caryophyllene (0.7 microg/g), and caryophyllene oxide (20.0 microg/g). The relative standard error and detection limit of this method is 5-9% and 0.4 microg/g, respectively.

  16. Salting-out assisted liquid-liquid extraction combined with gas chromatography-mass spectrometry for the determination of pyrethroid insecticides in high salinity and biological samples.

    Science.gov (United States)

    Niu, Zongliang; Yu, Chunwei; He, Xiaowen; Zhang, Jun; Wen, Yingying

    2017-09-05

    A salting-out assisted liquid-liquid extraction (SALLE) combined with gas chromatography-mass spectrometry (GC-MS) method was developed for the determination of four pyrethroid insecticides (PYRs) in high salinity and biological samples. Several parameters including sample pH, salting-out solution volume and salting-out solution pH influencing the extraction efficiency were systematically investigated with the aid of orthogonal design. The optimal extraction conditions of SALLE were: 4mL of salting-out solution with pH=4 and the sample pH=3. Under the optimum extraction and determination conditions, good responses for four PYRs were obtained in a range of 5-5000ng/mL, with linear coefficients greater than 0.998. The recoveries of the four PYRs ranged from 74% to 110%, with standard deviations ranging from 1.8% to 9.8%. The limits of detection based on a signal-to-noise ratio of 3 were between 1.5-60.6ng/mL. The method was applied to the determination of PYRs in urine, seawater and wastewater samples with a satisfactory result. The results demonstrated that this SALLE-GC-MS method was successfully applied to determine PYRs in high salinity and biological samples. SALLE avoided the need for the elimination of salinity and protein in the sample matrix, as well as clean-up of the extractant. Most of all, no centrifugation or any special apparatus are required, make this a promising method for rapid sample preparation procedure. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Comparison of air-agitated liquid-liquid microextraction technique and conventional dispersive liquid-liquid micro-extraction for determination of triazole pesticides in aqueous samples by gas chromatography with flame ionization detection.

    Science.gov (United States)

    Farajzadeh, Mir Ali; Mogaddam, Mohammad Reza Afshar; Aghdam, Abdollah Abdollahi

    2013-07-26

    Two micro-extraction methods, air-agitated liquid-liquid microextraction (AALLME) and dispersive liquid-liquid microextraction (DLLME), have been compared with each other by applying them for the analysis of five triazole pesticides (penconazole, hexaconazole, diniconazole, tebuconazole and triticonazole) in aqueous samples by gas chromatography with flame ionization detection (GC-FID). In the AALLME method, which excludes any disperser solvent, much less volume of organic solvent is used. In order to form fine and dispersed organic droplets in the aqueous phase, the mixture of aqueous sample solution and extraction solvent is repeatedly aspirated and dispensed with a syringe. In the DLLME method, an appropriate mixture of extraction solvent and disperser solvent is rapidly injected by a syringe into the aqueous sample. Effect of the pertinent experimental factors on DLLME (i.e. identity and volume of the extraction and disperser solvents and ionic strength) and on AALLME (identity and volume of the extraction solvent, number of agitations, and ionic strength) were investigated. Under optimal conditions, limits of detection for the five target pesticides obtained by AALLME-GC-FID and DLLME-GC-FID ranged from 0.20 to 1.1ngmL(-1) and 1.9 to 5.9ngmL(-1), respectively. The relative standard deviations (RSDs, n=5) were in the range of 1-4% and 3-5% with the enrichment factors of 449-504 and 79-143 for AALLME-GC-FID and DLLME-GC-FID, respectively. Both of the compared methods are simple, fast, efficient, inexpensive and can be applied to the analysis of the five pesticides in different aqueous samples in which penconazole and hexaconazole were found. For spiked samples, the recoveries were in the ranges of 92-105%, and 92-104% for AALLME and DLLME, respectively. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Pressurized liquid extraction-gas chromatography-mass spectrometry analysis of fragrance allergens, musks, phthalates and preservatives in baby wipes.

    Science.gov (United States)

    Celeiro, Maria; Lamas, J Pablo; Garcia-Jares, Carmen; Llompart, Maria

    2015-03-06

    Baby wipes and wet toilet paper are specific hygiene care daily products used on newborn and children skin. These products may contain complexes mixtures of harmful chemicals. A method based on pressurized liquid extraction (PLE) followed by gas chromatography-mass spectrometry (GC-MS) has been developed for the simultaneous determination of sixty-five chemical compounds (fragrance allergens, preservatives, musks, and phthalates) in wipes and wet toilet paper for children. These compounds are legislated in Europe according Regulation EC No 1223/2009, being twelve of them banned for their use in cosmetics, and one of them, 3-iodo-2-propynyl butylcarbamate (IPBC), is banned in products intended for children under 3 years. Also, propyl-, and butylparaben will be prohibited in leave-on cosmetic products designed for application on the nappy area of children under 3 years from April 2015. PLE is a fast, simple, easily automated technique, which permits to integrate a clean-up step during the extraction process reducing analysis time and stages. The proposed PLE-based procedure was optimized on real non-spiked baby wipe samples by means of experimental design to study the influence on extraction of parameters such as extraction solvent, temperature, extraction time, and sorbent type. Under the selected conditions, the method was validated showing satisfactory linearity, and intra-day, and inter-day precision. Recoveries were between 80-115% for most of the compounds with relative standard deviations (RSD) lower than 15%. Finally, twenty real samples were analyzed. Thirty-six of the target analytes were detected, highlighting the presence of phenoxyethanol in all analyzed samples at high concentration levels (up to 0.8%, 800μgg(-1)). Methyl paraben (MeP), and ethyl paraben (EtP) were found in 40-50% of the samples, and the recently banned isobutyl paraben (iBuP) and isopropyl paraben (iPrP), were detected in one and seven samples, respectively, at concentrations between

  19. Liquid phase chromatography on microchips

    DEFF Research Database (Denmark)

    Kutter, Jörg Peter

    2012-01-01

    explosive development of, in particular, chromatographic separation systems on microchips, has, however, slowed down in recent years. This review takes a closer, critical look at how liquid phase chromatography has been implemented in miniaturized formats over the past several years, what is important...

  20. Simultaneous derivatization and ultrasound-assisted dispersive liquid-liquid microextraction of chloropropanols in soy milk and other aqueous matrices combined with gas-chromatography-mass spectrometry.

    Science.gov (United States)

    Carro, A M; González, P; Lorenzo, R A

    2013-12-06

    A novel approach involving ultrasound-assisted dispersive liquid-liquid microextraction (UA-DLLME) and derivatization combined with gas chromatography-mass spectrometry was developed for the determination of chloropropanols in water and beverages. UA-DLLME was optimized as less solvent-consuming and cost-effective extraction method for water, fruit juice, milk and soy milk samples. The effect of parameters such as the type and volume of extraction solvent, the type and volume of dispersive solvent, amount of derivatization agent, temperature, pH of sample and ionic strength was investigated and optimized for each specimen, using experimental designs. By adding acetonitrile as dispersive solvent, N-heptafluorobutyrylimizadole (HFBI) as derivatization agent and chloroform as extraction solvent, the extraction-derivatization and preconcentration were simultaneously performed. The analytical concentration range was investigated in detail for each analyte in the different samples, obtaining linearity with R(2) ranging between 0.9990 and 0.9999. The method detection limits were in the range of 0.2-1.8μgL(-1) (water), 0.5-15μgL(-1) (fruit juices) and 0.9-3.6μgkg(-1) (milk) and 0.1-1.0μgkg(-1) (soy milk). The method was applied to the analysis of a variety of specimens, with recoveries of 98-101% from water, 97-102% from juices, 99-103% from milk and 97-105% from soy beverage. The relative standard deviation (precision, n=6) varied between 1.3 and 4.9%RSD in water, 2.3 and 5.8%RSD in juices, 1.0 and 5.7%RSD in milk and 3.9 and 9.3%RSD in soy milk. The proposed method was applied to analysis of twenty-eight samples. 1,3-Dichloro-2-propanol was found in an influent water sample from urban wastewater treatment plant (WWTP) (2.1±0.04mgL(-1)) but no chloropropanols were found in the corresponding effluent water sample. This result suggests that the purification system used in the WWTP has been effective for this compound. Moreover, the results revealed the presence of 3

  1. Identification of chemical components in Baidianling Capsule based on gas chromatography-mass spectrometry and high-performance liquid chromatography combined with Fourier transform ion cyclotron resonance mass spectrometry.

    Science.gov (United States)

    Wu, Wenying; Chen, Yu; Wang, Binjie; Sun, Xiaoyang; Guo, Ping; Chen, Xiaohui

    2017-08-01

    Baidianling Capsule, which is made from 16 Chinese herbs, has been widely used for treating vitiligo clinically. In this study, the sensitive and rapid method has been developed for the analysis of chemical components in Baidianling Capsule by gas chromatography-mass spectrometry in combination with retention indices and high-performance liquid chromatography combined with Fourier transform ion cyclotron resonance mass spectrometry. Firstly, a total of 110 potential volatile compounds obtained from different extraction procedures including alkanes, alkenes, alkynes, ketones, ethers, aldehydes, alcohols, phenols, organic acids, esters, furans, pyrrole, acid amides, heterocycles, and oxides were detected from Baidianling Capsule by gas chromatography-mass spectrometry, of which 75 were identified by mass spectrometry in combination with the retention index. Then, a total of 124 components were tentatively identified by high-performance liquid chromatography combined with Fourier transform ion cyclotron resonance mass spectrometry. Fifteen constituents from Baidianling Capsule were accurately identified by comparing the retention times with those of reference compounds, others were identified by comparing the retention times and mass spectrometry data, as well as retrieving the reference literature. This study provides a practical strategy for rapidly screening and identifying the multiple constituents of a complex traditional Chinese medicine. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Gas chromatography: mass selective detector

    International Nuclear Information System (INIS)

    Lapinskas, R.

    1988-01-01

    The mechanism of mass spectrometry technique directed for detecting molecular structures is described, with some considerations about its operational features. This mass spectrometer is used as a gas chromatography detector. (author)

  3. Gas chromatography-electron ionization mass spectrometry and liquid chromatography-electrospray tandem mass spectrometry for determination of impurities in the anti-cancer drug isophosphoramide mustard

    Science.gov (United States)

    Cole, Richard B.; Chou, Chau-Wen; Boué, Stephen M.; Leblanc, Blaise W.; Rodgers, Andrew H.; Struck, Robert F.; Morgan, Lee Roy

    2004-02-01

    Isophosphoramide mustard (IPM) is known to have substantial anti-cancer activities in various animal models. Liquid chromatography-electrospray mass spectrometry (LC-ES-MS) and LC-ES-MS/MS methodologies have been developed and applied to the analysis of synthesized preparations of IPM. Our studies reveal that the principal impurity in IPM is N-(2-chloroethyl)-N'-ethylphosphorodiamidic acid (MC-IPM) formed by dehydrochlorination of IPM with subsequent hydrogenation during synthesis. This impurity is present at levels in the range of 2-5% depending upon synthesis conditions. In addition, a second IPM derivative has been characterized by LC-ES-MS/MS and has been shown to be the product of a reaction of IPM with the dilute perchloric acid mobile phase used for liquid chromatography separations. The LC-ES-MS/MS method has been successfully employed to detect IPM spiked into a blood plasma sample. This work establishes that LC-ES-MS/MS is a viable tool for the detailed characterization of IPM and related products.

  4. Optimization of an accelerated solvent extraction dispersive liquid-liquid microextraction method for the separation and determination of essential oil from Ligusticum chuanxiong Hort by gas chromatography with mass spectrometry.

    Science.gov (United States)

    Yang, Guang; Sun, Qiushi; Hu, Zhiyan; Liu, Hua; Zhou, Tingting; Fan, Guorong

    2015-10-01

    In this study, an accelerated solvent extraction dispersive liquid-liquid microextraction coupled with gas chromatography and mass spectrometry was established and employed for the extraction, concentration and analysis of essential oil constituents from Ligusticum chuanxiong Hort. Response surface methodology was performed to optimize the key parameters in accelerated solvent extraction on the extraction efficiency, and key parameters in dispersive liquid-liquid microextraction were discussed as well. Two representative constituents in Ligusticum chuanxiong Hort, (Z)-ligustilide and n-butylphthalide, were quantitatively analyzed. It was shown that the qualitative result of the accelerated solvent extraction dispersive liquid-liquid microextraction approach was in good agreement with that of hydro-distillation, whereas the proposed approach took far less extraction time (30 min), consumed less plant material (usually extraction and analysis of essential oil. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Determination of the content of alkyl ketene dimer in its latex by an ionic-liquid assisted headspace gas chromatography.

    Science.gov (United States)

    Yan, Ning; Wan, Xiao-Fang; Chai, Xin-Sheng; Chen, Run-Quan; Chen, Chun-Xia

    2017-12-29

    This paper reports on an ionic-liquid assisted headspace gas chromatographic (HS-GC) for the determination of the content of alkyl ketene dimer (AKD) in its latex samples, in which the GC system was equipped with a thermal conductivity detector (TCD). The method was based on the AKD hydrolysis conducted in 1-butyl-3-methylimidazolium chloride (ionic-liquid) added medium at 100°C for 10min in a closed headspace sample vial, and the measured CO 2 (the resulting product of the hydrolysis) by HS-GC. The results showed that the present method has a good measurement precision (RSD latex sample in mill applications. The study also showed that the content of AKD in the tested commercial latex samples were in the range of 3.5-12%. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Urinary screening for methylphenidate (Ritalin) abuse: a comparison of liquid chromatography-tandem mass spectrometry, gas chromatography-mass spectrometry, and immunoassay methods.

    Science.gov (United States)

    Eichhorst, J; Etter, M; Lepage, J; Lehotay, D C

    2004-03-01

    To develop a routine method for detecting methylphenidate (Ritalin) use among drug abusers using liquid chromatography-tandem mass spectrometry (LC/MS/MS). The new methodology was designed to replace less reliable and/or more expensive and time-consuming techniques (GC/MS and ELISA) currently employed in our laboratory, and to provide a combined one-step screening and confirmation LC/MS/MS method. Because methylphenidate abuse is very prevalent in Saskatchewan, there is a demand to provide high volume urine screening both to detect abuse, and to monitor compliance. Random urine samples sent for drugs of abuse testing, standards, and controls were diluted 1:100 in methanol. Diluted specimens were injected directly into an Agilent 1100 liquid chromatograph coupled to a Sciex API 2000 mass spectrometer. The method utilized selected reaction monitoring (SRM) as well as an electrospray ionization source (EIS) to detect both urinary methylphenidate and the more prevalent metabolite, ritalinic acid (RA). There appeared to be little or no sacrifice in sensitivity because the higher dilutions exhibited much less matrix effect. Limit of quantitation (LOQ) for methylphenidate was 100 nM and 500 nM for RA. Linear calibration curves from 100 to 1000 nM for Ritalin and 500 to 5000 nM for RA were acquired. Imprecision of spiked and true specimens did not exceed 10% and at the LOQ, it was less than 20%. A rapid, sensitive, reliable, and highly specific method by LC/MS/MS for detecting methylphenidate and its metabolite, RA, were developed. Both the cost and performance of the LC/MS/MS method were superior to GC/MS or ELISA, and it allows use of a single rapid procedure for both screening and confirmation.

  7. High perfomance liquid chromatography in pharmaceutical analyses.

    Science.gov (United States)

    Nikolin, Branko; Imamović, Belma; Medanhodzić-Vuk, Saira; Sober, Miroslav

    2004-05-01

    In testing the pre-sale procedure the marketing of drugs and their control in the last ten years, high performance liquid chromatography replaced numerous spectroscopic methods and gas chromatography in the quantitative and qualitative analysis. In the first period of HPLC application it was thought that it would become a complementary method of gas chromatography, however, today it has nearly completely replaced gas chromatography in pharmaceutical analysis. The application of the liquid mobile phase with the possibility of transformation of mobilized polarity during chromatography and all other modifications of mobile phase depending upon the characteristics of substance which are being tested, is a great advantage in the process of separation in comparison to other methods. The greater choice of stationary phase is the next factor which enables realization of good separation. The separation line is connected to specific and sensitive detector systems, spectrafluorimeter, diode detector, electrochemical detector as other hyphernated systems HPLC-MS and HPLC-NMR, are the basic elements on which is based such wide and effective application of the HPLC method. The purpose high performance liquid chromatography (HPLC) analysis of any drugs is to confirm the identity of a drug and provide quantitative results and also to monitor the progress of the therapy of a disease.1) Measuring presented on the Fig. 1. is chromatogram obtained for the plasma of depressed patients 12 h before oral administration of dexamethasone. It may also be used to further our understanding of the normal and disease process in the human body trough biomedical and therapeutically research during investigation before of the drugs registration. The analyses of drugs and metabolites in biological fluids, particularly plasma, serum or urine is one of the most demanding but one of the most common uses of high performance of liquid chromatography. Blood, plasma or serum contains numerous endogenous

  8. An analytical study by gas liquid chromatography and radiochromatography of tritium labelled lebaycid; Estudio Analitico del proceso de sistesis del lebaycid marcado contritio por cromatogria gas liquido y radiocromatografia

    Energy Technology Data Exchange (ETDEWEB)

    Perez Garcia, M. M.

    1969-07-01

    The stability and purity of the syntheses products of Lebaycid: 0,0 dime thylfosfochlorothionate and 4 methyl-thio-m-cresol were investigated by gas liquid chromatography. The study on (CH{sub 3}O){sub 2} PSC1 was made in a column of Silicone SE-30, Reoplex 400 using a thermal conductivity detector. The 99,4% pure product obtained from the preparative gas chromatograph was found to be stable within the duration of the experiment: seven months. (Author) 23 refs.

  9. Detection of human butyrylcholinesterase-nerve gas adducts by liquid chromatography-mass spectrometric analysis after in gel chymotryptic digestion.

    Science.gov (United States)

    Tsuge, Kouichiro; Seto, Yasuo

    2006-06-21

    To verify the exposure to nerve gas, a method for detecting human butyrylcholinesterase (BuChE)-nerve gas adduct was developed using LC-electrospray mass spectrometry (ESI-MS). Purified human serum BuChE was incubated with sarin, soman or VX, and the adduct was purified by sodium dodecylsulfate polyacrylamide gel electrophoresis (SDS-PAGE) and digested in gel by treatment with chymotrypsin. The resulting peptide mixture was subjected to LC-ESI-MS. From the chymotryptic digest of untreated human BuChE, one peak corresponding to the peptide fragment containing the active center serine residue was detected on the extracted ion chromatogram at m/z 948.5, and the sequence was ascertained to be "GESAGAASVSL" by MS/MS analysis. From the chymotryptic digest of the human BuChE-sarin adduct, a singly charged peptide peak was detected on the extracted ion chromatogram at m/z 1,069.5, and the sequence was ascertained to be "GEXAGAASVSL" by MS/MS analysis (X denotes isopropylmethylphosphonylated serine). The difference in molecular weight (120.0 Da) between the active center peptide fragments corresponding to the untreated BuChE and BuChE-sarin adduct was assumed to be derived from the addition of an isopropyl methylphosphonyl moiety to the serine residue. The formation of human BuChE adducts with soman, VX and an aged soman adduct was confirmed by detecting the respective active center peptide fragments using LC-ESI-MS. To apply the established method to an actual biological sample, human serum was incubated with VX, and the adduct was purified by procainamide affinity chromatography followed by SDS-PAGE. After chymotryptic in gel digestion, the ethylphosphonylated active center peptide fragment could be detected, and the structure of the residue was ascertained by LC-ESI-MS analysis.

  10. Towards chemical profiling of ignitable liquids with comprehensive two-dimensional gas chromatography: Exploring forensic application to neat white spirits.

    Science.gov (United States)

    Sampat, Andjoe A S; Lopatka, Martin; Vivó-Truyols, Gabriel; Schoenmakers, Peter J; van Asten, Arian C

    2016-10-01

    The application of GC×GC-FID and GC×GC-MS for the chemical analysis and profiling of neat white spirit is explored and the benefit of the enhanced peak capacity offered by comprehensive two-dimensional gas chromatography is demonstrated. An extensive sampling exercise was conducted throughout The Netherlands and the production and logistics in terms of bottling and distribution of white spirits were studied. An exploratory approach based on target-peak tables and principal component analysis was employed to study the brand-to-brand differences and production variations over time. Despite the complex chemical composition of white spirit samples this study shows that chemical variation during productions is actually quite limited. Hence care has to be taken with the chemical comparison for forensic purposes. Although some clustering was noticed on brand level, the large scale production process leads to a very consistent composition across stores and brands. However, because of the broad specifications of this commodity product, substantial chemical variation was found over time. This temporal discrimination could be of forensic value when considering white spirits supplies in individual households. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. Comparison of available analytical methods to measure trans-octadecenoic acid isomeric profile and content by gas-liquid chromatography in milk fat.

    Science.gov (United States)

    Destaillats, Frédéric; Golay, Pierre-Alain; Joffre, Florent; de Wispelaere, Maureen; Hug, Bernadette; Giuffrida, Francesca; Fauconnot, Laetitia; Dionisi, Fabiola

    2007-03-23

    Accurate quantification of trans-fatty acids (TFAs) could be achieved by infrared spectroscopy or by gas-liquid chromatography (GLC). Accurate quantification by GLC should be achieved using specific highly polar capillary columns such as 100 m CP-Sil 88 or equivalent. A pre-fractionation of cis and trans-fatty acids could be performed by silver-ion thin-layer chromatography (Ag-TLC), silver-ion solid-phase extraction (Ag-SPE), or by high-performance liquid-chromatography (HPLC). A pre-fractionation step allows accurate determination of the isomeric profile but it is not essential to achieve quantification of total trans-18:1 isomers nor to determine the level of vaccenic (trans-11 18:1) acid in dairy fat. TFA content could also be calculated in milk fat based on the TAG profile determined by GLC. In this paper, different GLC methods suitable to measure the total of trans-18:1 isomers, vaccenic acid and trans-18:1 acid isomeric distribution in milk fat were compared. Pre-separation of cis- and trans-18:1 isomers by Ag-TLC followed by GLC analysis under optimal conditions was selected as the reference method. Results obtained using alternative methods including pre-separation by HPLC followed by GLC analysis, direct quantification by GLC or calculation from the triacylglycerol (TAG) profile were compared to data acquired using the reference method. Results showed that accurate quantification of total trans-18:1 isomers and vaccenic acid could be achieved by direct quantification by GLC under optimal chromatographic conditions. This method represents a very good alternative to Ag-TLC followed by GLC analysis. On the other hand, we showed that pre-fractionation of fatty acid methyl esters (FAMEs) by HPLC represents a good alternative to Ag-TLC, even if some minor isomers are not selectively purified using this procedure.

  12. Miniaturized hollow fiber assisted liquid-phase microextraction and gas chromatography-mass spectrometry for the measurement of progesterone in human serum.

    Science.gov (United States)

    Kawaguchi, Migaku; Takatsu, Akiko

    2009-01-15

    Miniaturized hollow fiber assisted liquid-phase microextraction (HF-LPME) and gas chromatography-mass spectrometry (GC-MS) for the determination of progesterone in human serum sample is described. The detection limit and the quantification limit of progesterone in human serum sample are 0.5 and 2 ng mL(-1) (ppb), respectively. The calibration curve for progesterone is linear with a correlation coefficient of >0.999 in the range of 2-500 ng mL(-1). The average recoveries of progesterone in human serum samples spiked with 5, 50 and 200 ng mL(-1) progesterone are 97.4% (R.S.D.: 9.3%), 100.3% (R.S.D.: 4.7%) and 99.8% (R.S.D.: 3.4%), respectively. This simple, accurate, sensitive and selective analytical method can be applicable for the determination of progesterone in human serum samples.

  13. Hollow fiber liquid-phase microextraction-gas chromatography-mass spectrometry method to analyze bisphenol A and other plasticizer metabolites.

    Science.gov (United States)

    Fernandez, Miriany A Moreira; André, Leiliane Coelho; Cardeal, Zenilda de Lourdes

    2017-01-20

    Phthalates and bisphenol A are important environmental pollutants due to their toxicity for humans and animals, including actions in the endocrine system. Their metabolites in urine can be used as biomarkers to assess human exposure. This paper describes the development of a new method to determine bisphenol A and eight phthalate metabolites in urine samples using hollow fiber liquid phase microextraction (HF-LPME) and gas chromatography-mass spectrometry (GC-MS). This method showed linearity, precision, limits of detection, and quantification suitable to analyze these compounds at low concentration levels in urine. Limits of detection ranged from 0.777 to 23.3μgL -1 , showing sensitivity for evaluating environmental exposure. Relative standard deviation (RSD) ranged from 11.7 to 19.7%. The developed method presented a good biomarker alternative for evaluating environmental exposure to bisphenol A and phthalates. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Simultaneous determination of endogenous steroid hormones in human and animal plasma and serum by liquid or gas chromatography coupled to tandem mass spectrometry.

    Science.gov (United States)

    Abdel-Khalik, Jonas; Björklund, Erland; Hansen, Martin

    2013-06-01

    Analytical methodologies based on liquid or gas chromatography coupled to tandem mass spectrometry for the simultaneous determination of two or more endogenous steroid hormones in human and animal plasma and serum has received increased attention the last few years. Especially in the clinical setting steroid profiling is of major importance in disease diagnostics. This paper discusses recent findings in such multi-steroid hormone procedures published from 2001 to 2012. The aim was to elucidate possible relationships between chosen analytical technique and the obtained analyte sensitivity for endogenous steroid hormones. By evaluating the success, at which the currently applied techniques have been utilized, more general knowledge on the field is provided. Furthermore the evaluation provides directions in which future studies may be interesting to conduct. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Rapid analysis of ethanol and water in commercial products using ionic liquid capillary gas chromatography with thermal conductivity detection and/or barrier discharge ionization detection.

    Science.gov (United States)

    Weatherly, Choyce A; Woods, Ross M; Armstrong, Daniel W

    2014-02-26

    Analysis of ethanol and water in consumer products is important in a variety of processes and often is mandated by regulating agencies. A method for the simultaneous quantitation of ethanol and water that is simple, accurate, precise, rapid, and cost-effective is demonstrated. This approach requires no internal standard for the quantitation of both ethanol and water at any/all levels in commercial products. Ionic liquid based gas chromatography (GC) capillary columns are used to obtain a fast analysis with high selectivity and resolution of water and ethanol. Typical run times are just over 3 min. Examination of the response range of water and ethanol with GC, thermal conductivity detection (TCD), and barrier ionization detection (BID) is performed. Quantitation of both ethanol and water in consumer products is accomplished with both TCD and BID GC detectors using a nonlinear calibration. Validation of method accuracy is accomplished by using standard reference materials.

  16. Ignitable liquid identification using gas chromatography/mass spectrometry data by projected difference resolution mapping and fuzzy rule-building expert system classification.

    Science.gov (United States)

    Lu, Weiying; Rankin, J Graham; Bondra, Alexandria; Trader, Carolyn; Heeren, Amanda; Harrington, Peter de B

    2012-07-10

    The gasoline and kerosene collected from different locations in the United States were identified by gas chromatography/mass spectrometry (GC/MS) followed by chemometric analysis. Classifications based on two-way profiles and target component ratios were compared. The projected difference resolution (PDR) mapping was applied to measure the differences among the ignitable liquid (IL) samples by their GC/MS profiles quantitatively. Fuzzy rule-building expert systems (FuRESs) were applied to classify individual ILs. The FuRES models yielded correct classification rates greater than 90% for discriminating between samples. PDR mapping, a new method for characterizing complex data sets was consistent with the FuRES classification result. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  17. Nonequilibrium hollow-fiber liquid-phase microextraction with in situ derivatization for the measurement of triclosan in aqueous samples by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Zhao, Ru-Song; Yuan, Jin-Peng; Li, Hai-Fang; Wang, Xu; Jiang, Ting; Lin, Jin-Ming

    2007-04-01

    Hollow-fiber liquid-phase microextraction (HF-LPME), a relatively new sample preparation technique, has attracted much interest in the field of environmental analysis. In the current study, a novel method based on hollow-fiber liquid-phase microextraction with in situ derivatization and gas chromatography-mass spectrometry for the measurement of triclosan in aqueous samples is described. Hollow-fiber liquid-phase microextraction conditions such as the type of extraction solvent, the stirring rate, the volume of derivatizing reagent, and the extraction time were investigated. When the conditions had been optimized, the linear range was found to be 0.05-100 microg l(-1) for triclosan, and the limit of detection to be 0.02 microg l(-1). Tap water and surface water samples collected from our laboratory and Wohushan reservoir, respectively, were successfully analyzed using the proposed method. The recoveries from the spiked water samples were 83.6 and 114.1%, respectively; and the relative standard deviation (RSD) at the 1.0 microg l(-1) level was 6.9%.

  18. Simultaneous determination of levodopa and carbidopa from fava bean, green peas and green beans by high performance liquid gas chromatography.

    Science.gov (United States)

    Mehran S M, Mohseni; B, Golshani

    2013-06-01

    According to many studies, sprouted fava beans are a rich source of levo-dihydroxy phenylalanine (L-dopa) the precursor of dopamine, and they are now being investigated for use in the management of Parkinson's disease. The addition of Carbidopa (C-dopa) can reduce the daily use of the L-dopa dosage requirements and it can also reduce the side effects which are associated with the L-dopa administration. The present research was conducted to find the levo-dihydroxy phenylalanine (L-dopa) and Carbidopa (C-dopa) in fava beans, green peas and green beans by High Performance Gas Chromatography (HPLC). Carbidopa (C-dopa) is a peripheral decarboxylase inhibitor. As a substitution therapy, it used in combination to treat Parkinson's disease. We obtained L-dopa and C-dopa from fava beans which were in the fresh and dry sprouted form, whose concentrations were 1.4,1.5 and 2.6,2.4 mg/ml respectively. The maximal stimulation of the L-DOPA content was seen on day 8 for the fava beans, which was 100% higher than that of the control level. The results of this study indicate that faba beans are a good source of natural L-dopa and C-dopa. The quantification of this capacity according to the stage and the plant part could be suitable for applications in the food industry and in plant medicine. The consumption of fava beans can increase the levels of L-dopa and C-dopa in the blood, with a marked improvement in the motor performance of the patients with parkinson disease, without any side effects.

  19. Chromatography

    Science.gov (United States)

    ... that are bonded together. For example, water is a chemical bond of oxygen and hydrogen. Proteins are another type of chemical compound. There are different kinds of chromatography. These include gas, high pressure liquid, or ion ...

  20. Characterisation of dense non-aqueous phase liquids of coal tar using comprehensive two-dimensional gas chromatography coupled with time of flight mass spectrometry.

    Science.gov (United States)

    Gauchotte-Lindsay, Caroline; McGregor, Laura; Richards, Phil; Kerr, Stephanie; Glenn, Aliyssa; Thomas, Russell; Kalin, Robert

    2013-04-01

    Comprehensive two-dimensional gas chromatography (GCxGC) is a recently developed analytical technique in which two capillary columns with different stationary phases are placed in series enabling planar resolution of the analytes. The resolution power of GCxGC is one order of magnitude higher than that of one dimension gas chromatography. Because of its high resolution capacity, the use of GCxGC for complex environmental samples such as crude oils, petroleum derivatives and polychlorinated biphenyls mixtures has rapidly grown in recent years. We developed a one-step method for the forensic analysis of coal tar dense non-aqueous phase liquids (DNAPLs) from former manufactured gas plant (FMGP) sites. Coal tar is the by-product of the gasification of coal for heating and lighting and it is composed of thousands of organic and inorganic compounds. Before the boom of natural gases and oils, most towns and cities had one or several manufactured gas plants that have, in many cases, left a devastating environmental print due to coal tar contamination. The fate of coal tar DNAPLs, which can persist in the environment for more than a hundred years, is therefore of crucial interest. The presented analytical method consists of a unique clean-up/ extraction stage by pressurized liquid extraction and a single analysis of its organic chemical composition using GCxGC coupled with time of flight mass spectrometry (TOFMS). The chemical fingerprinting is further improved by derivatisation by N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) of the tar compounds containing -OH functions such as alcohols and carboxylic acids. We present here how, using the logical order of elution in GCxGC-TOFMS system, 1) the identification of never before observed -OH containing compounds is possible and 2) the isomeric selectivity of an oxidation reaction on a DNAPL sample can be revealed. Using samples collected at various FMGP sites, we demonstrate how this GCxGC method enables the simultaneous

  1. Environmental application of elemental speciation analysis based on liquid or gas chromatography hyphenated to inductively coupled plasma mass spectrometry-A review

    Energy Technology Data Exchange (ETDEWEB)

    Popp, Maximilian [Department of Chemistry, Division of Analytical Chemistry, University of Natural Resources and Applied Life Sciences, BOKU Vienna, Muthgasse 18, A-1190 Vienna (Austria); Hann, Stephan [Department of Chemistry, Division of Analytical Chemistry, University of Natural Resources and Applied Life Sciences, BOKU Vienna, Muthgasse 18, A-1190 Vienna (Austria); Koellensperger, Gunda, E-mail: Gunda.Koellensperger@boku.ac.at [Department of Chemistry, Division of Analytical Chemistry, University of Natural Resources and Applied Life Sciences, BOKU Vienna, Muthgasse 18, A-1190 Vienna (Austria)

    2010-06-04

    In recent years the number of environmental applications of elemental speciation analysis using inductively coupled plasma mass spectrometry (ICP-MS) as detector has increased significantly. The analytical characteristics, such as extremely low detection limits (LOD) for almost all elements, the wide linear range, the possibility for multi-elemental analysis and the possibility to apply isotope dilution mass spectrometry (IDMS) make ICP-MS an attractive tool for elemental speciation analysis. Two methodological approaches, i.e. the combination of ICP-MS with high performance liquid chromatography (HPLC) and gas chromatography (GC), dominate the field. Besides the investigation of metals and metalloids and their species (e.g. Sn, Hg, As), representing 'classic' elements in environmental science, more recently other elements (e.g. P, S, Br, I) amenable to ICP-MS determination were addressed. In addition, the introduction of isotope dilution analysis and the development of isotopically labeled species-specific standards have contributed to the success of ICP-MS in the field. The aim of this review is to summarize these developments and to highlight recent trends in the environmental application of ICP-MS coupled to GC and HPLC.

  2. Characterization of Mycobacterium paratuberculosis by gas-liquid and thin-layer chromatography and rapid demonstration of mycobactin dependence using radiometric methods

    International Nuclear Information System (INIS)

    Damato, J.J.; Knisley, C.; Collins, M.T.

    1987-01-01

    Thirty-six Mycobacterium paratuberculosis isolates of bovine, caprine, and ovine origins were evaluated by using gas-liquid chromatography (GLC), thin-layer chromatography (TLC), and BACTEC 7H12 Middlebrook TB medium in an effort to more rapidly differentiate this group of organisms from other mycobacteria. Bacterial suspensions (0.1 ml) were inoculated by syringe into 7H12 broth containing 2 micrograms of mycobactin P per ml and control broth without mycobactin P. Cultures were incubated at 37 0 C and read daily with a BACTEC Model 301. After 8 days of incubation, the growth index readings for the test broths containing mycobactin P were twice those of the control broths without mycobactin P. Sixty-five isolates of mycobacteria other than M. paratuberculosis were also examined. No difference was noted between the growth index readings of control and mycobactin-containing broths. Except for Mycobacterium avium-Mycobacterium intracellulare, TLC studies differentiated M. paratuberculosis from the other mycobacterial species tested. The GLC data reveal that all M. paratuberculosis isolates had a distinctive peak (14A) which was not found among M. avium-M. intracellulare complex organisms. These data indicate that 7H12 radiometric broth was able to rapidly demonstrate the mycobactin dependence of M. paratuberculosis and GLC and TLC procedures were capable of rapidly differentiating this organism from the other mycobacteria studied

  3. Environmental application of elemental speciation analysis based on liquid or gas chromatography hyphenated to inductively coupled plasma mass spectrometry-A review

    International Nuclear Information System (INIS)

    Popp, Maximilian; Hann, Stephan; Koellensperger, Gunda

    2010-01-01

    In recent years the number of environmental applications of elemental speciation analysis using inductively coupled plasma mass spectrometry (ICP-MS) as detector has increased significantly. The analytical characteristics, such as extremely low detection limits (LOD) for almost all elements, the wide linear range, the possibility for multi-elemental analysis and the possibility to apply isotope dilution mass spectrometry (IDMS) make ICP-MS an attractive tool for elemental speciation analysis. Two methodological approaches, i.e. the combination of ICP-MS with high performance liquid chromatography (HPLC) and gas chromatography (GC), dominate the field. Besides the investigation of metals and metalloids and their species (e.g. Sn, Hg, As), representing 'classic' elements in environmental science, more recently other elements (e.g. P, S, Br, I) amenable to ICP-MS determination were addressed. In addition, the introduction of isotope dilution analysis and the development of isotopically labeled species-specific standards have contributed to the success of ICP-MS in the field. The aim of this review is to summarize these developments and to highlight recent trends in the environmental application of ICP-MS coupled to GC and HPLC.

  4. Comparison of hollow fiber liquid phase microextraction and dispersive liquid-liquid microextraction for the determination of organosulfur pesticides in environmental and beverage samples by gas chromatography with flame photometric detection.

    Science.gov (United States)

    Xiong, Jun; Hu, Bin

    2008-06-06

    Two methods based on hollow fiber liquid phase microextraction (HF-LPME) and dispersive liquid-liquid microextraction (DLLME), have been critically compared for the analysis of organosulfur pesticides (OSPs) in environmental and beverage samples by gas chromatography-flame photometric detection (GC-FPD). Experimental conditions including extraction solvent, solvent volume, extraction time, temperature and ionic strength have been investigated for both HF-LPME and DLLME. Under the optimal conditions, the limits of detection for the six target OSPs (malathion, chlorpyrifos, buprofezin, triazophos, carbosulfan and pyridaben) obtained by HF-LPME-GC-FPD and DLLME-GC-FPD were ranged from 1.16 microg/L to 48.48 microg/L and 0.21 microg/L to 3.05 microg/L, respectively. The relative standard deviations (RSDs, n=5) were in the range of 3.4-8.0% and 8.5-13.7%with the enrichment factors (EFs) of 27-530 and 176-946 folds for HF-LPME-GC-FPD and DLLME-GC-FPD, respectively. Both methods were found to be simple, fast, efficient, and inexpensive. Compared with HF-LPME, the advantages of DLLME technique were less extraction time, suitable for batches of samples pretreatment simultaneously, a higher extraction capacity when analyzing simple samples such as water samples. While for the analysis of complicated matrix samples such as soil and beverage samples, HF-LPME was demonstrated to be more robust and more suitable. Both methods were applied to the analysis of six OSPs in different waters, soil and beverage samples, and no target OSPs was found in these samples. For analysis of the spiked samples, the recovery of 81.7-114.4% with RSDs of 0.6-9.6% were obtained for HF-LPME, and the recovery of 78.5-117.2% with RSDs of 0.6-11.9% were obtained for DLLME.

  5. Comparison of hollow fiber liquid-phase microextraction and ultrasound-assisted low-density solvent dispersive liquid-liquid microextraction for the determination of drugs of abuse in biological samples by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Meng, Liang; Zhang, Wenwen; Meng, Pinjia; Zhu, Binling; Zheng, Kefang

    2015-05-01

    Two microextraction techniques based on hollow fiber liquid-phase microextraction (HF-LPME) and ultrasound-assisted low-density solvent dispersive liquid-liquid microextraction (UA-LDS-DLLME) had been applied for the determination of drugs of abuse (methamphetamine, amphetamine, 3,4-methylenedioxymethamphetamine, 3,4-methylenedioxyamphetamine, methcathinone, ketamine, meperidine, and methadone) in urine and blood samples by gas chromatography-mass spectrometry. Parameters affecting extraction efficiency have been investigated and optimized for both methods. Under the optimum conditions, linearities were observed for all analytes in the range 0.0030-10 μg/ml with the correlation coefficient (R) ranging from 0.9985 to 0.9995 for HF-LPME and in the range 0.0030-10 μg/ml with the R ranging from 0.9985 to 0.9994 for DLLME. The recovery of 79.3-98.6% with RSDs of 1.2-4.5% was obtained for HF-LPME, and the recovery of 79.3-103.4% with RSDs of 2.4-5.7% was obtained for DLLME. The LODs (S/N=3) were estimated to be in the range from 0.5 to 5 ng/ml and 0.5 to 4 ng/ml, respectively. Compared with HF-LPME, the UA-LDS-DLLME technique had the advantages of less extraction time, suitability for batches of sample pretreatment simultaneously, and higher extraction efficiency, while HF-LPME has excellent sample clean-up effect, and is a robust and suitable technique for various sample matrices with better repeatability. Both methods were successfully applied to the analysis of drugs of abuse in real human blood sample. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Determination of paraffins in food simulants and packaging materials by liquid chromatography with evaporative mass detection and identification of paraffin type by liquid chromatography/gas chromatography and fourier transform infrared spectroscopy

    NARCIS (Netherlands)

    Simal-Gándara, J.; Sarria-Vidal, M.; Rijk, M.A.H.

    2000-01-01

    A liquid chromatographic method with evaporative mass detection (EMD) is described for the determination of paraffins in food contact materials that do not contain polyolefin oligomers, or paraffins migrating from these materials into fatty food simulants or certain simple foods. A normal-phase

  7. Determination of vitamins D2 and D3 in selected food matrices by online high-performance liquid chromatography-gas chromatography-mass spectrometry (HPLC-GC-MS).

    Science.gov (United States)

    Nestola, Marco; Thellmann, Andrea

    2015-01-01

    An online normal-phase liquid chromatography-gas chromatography-mass spectrometry (HPLC-GC-MS) method was developed for the determination of vitamins D2 and D3 in selected food matrices. Transfer of the sample from HPLC to GC was realized by large volume on-column injection; detection was performed with a time-of-flight mass spectrometer (TOF-MS). Typical GC problems in the determination of vitamin D such as sample degradation or sensitivity issues, previously reported in the literature, were not observed. Determination of total vitamin D content was done by quantitation of its pyro isomer based on an isotopically labelled internal standard (ISTD). Extracted ion traces of analyte and ISTD showed cross-contribution, but non-linearity of the calibration curve was not determined inside the chosen calibration range by selection of appropriate quantifier ions. Absolute limits of detection (LOD) and quantitation (LOQ) for vitamins D2 and D3 were calculated as approximately 50 and 150 pg, respectively. Repeatability with internal standard correction was below 2 %. Good agreement between quantitative results of an established high-performance liquid chromatography with UV detection (HPLC-UV) method and HPLC-GC-MS was found. Sterol-enriched margarine was subjected to HPLC-GC-MS and HPLC-MS/MS for comparison, because HPLC-UV showed strong matrix interferences. HPLC-GC-MS produced comparable results with less manual sample cleanup. In summary, online hyphenation of HPLC and GC allowed a minimization in manual sample preparation with an increase of sample throughput.

  8. A novel method for determination and quantification of 4-methyloctanoic and 4-methylnonanoic acids in mutton by hollow fiber supported liquid membrane extraction coupled with gas chromatography.

    Science.gov (United States)

    Chen, Haigui; Wang, Yunfan; Jiang, Houyang; Zhao, Guohua

    2012-12-01

    4-Methyloctanoic acid (MOA) and 4-methylnonanoic acid (MNA) are the main compounds responsible for "sweaty" odor of mutton. A novel method for their determination has been developed and validated. Hollow fiber supported liquid membrane (HF-SLM) was applied to selectively extract MOA and MNA prior to gas chromatography (GC) analysis. For HF-SLM, the donor outside the fiber was the acidified supernatant (pH 4) from aqueous mutton slurry. Liquid membrane was 5% tri-n-octylphoshphine oxide in di-n-hexyl ether and 0.3M NaOH aqueous solution filled in the lumen of the fiber was used as the acceptor. The extraction last for 4h. After acidification with HCl, the acceptor was directly analyzed by GC. Importantly, HF-SLM provided high enrichment factors for MOA (133) and MNA (116). The method developed had low detection limits of 0.0007-0.0015 mg/kg, good linearity (R²>0.9956), reasonable recovery (88.54-122.13%), satisfactory intra-assay (7.83-9.73%) and inter-assay (15.68-16.14%) precision. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. Simultaneous determination of creatinine and creatine in human serum by double-spike isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS).

    Science.gov (United States)

    Fernández-Fernández, Mario; Rodríguez-González, Pablo; Añón Álvarez, M Elena; Rodríguez, Felix; Menéndez, Francisco V Álvarez; García Alonso, J Ignacio

    2015-04-07

    This work describes the first multiple spiking isotope dilution procedure for organic compounds using (13)C labeling. A double-spiking isotope dilution method capable of correcting and quantifying the creatine-creatinine interconversion occurring during the analytical determination of both compounds in human serum is presented. The determination of serum creatinine may be affected by the interconversion between creatine and creatinine during sample preparation or by inefficient chemical separation of those compounds by solid phase extraction (SPE). The methodology is based on the use differently labeled (13)C analogues ((13)C1-creatinine and (13)C2-creatine), the measurement of the isotopic distribution of creatine and creatinine by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and the application of multiple linear regression. Five different lyophilized serum-based controls and two certified human serum reference materials (ERM-DA252a and ERM-DA253a) were analyzed to evaluate the accuracy and precision of the proposed double-spike LC-MS/MS method. The methodology was applied to study the creatine-creatinine interconversion during LC-MS/MS and gas chromatography-mass spectrometry (GC-MS) analyses and the separation efficiency of the SPE step required in the traditional gas chromatography-isotope dilution mass spectrometry (GC-IDMS) reference methods employed for the determination of serum creatinine. The analysis of real serum samples by GC-MS showed that creatine-creatinine separation by SPE can be a nonquantitative step that may induce creatinine overestimations up to 28% in samples containing high amounts of creatine. Also, a detectable conversion of creatine into creatinine was observed during sample preparation for LC-MS/MS. The developed double-spike LC-MS/MS improves the current state of the art for the determination of creatinine in human serum by isotope dilution mass spectrometry (IDMS), because corrections are made for all the possible errors

  10. Analysis of polycyclic aromatic hydrocarbons in soil and sediment with on-line coupled pressurised hot water extraction, hollow fibre microporous membrane liquid-liquid extraction and gas chromatography.

    Science.gov (United States)

    Kuosmanen, Kati; Hyötyläinen, Tuulia; Hartonen, Kari; Riekkola, Marja-Liisa

    2003-05-01

    Pressurised hot water extraction (PHWE) was coupled on-line via hollow fibre microporous membrane liquid-liquid extraction (HF-MMLLE) to gas chromatography (GC) and applied in the analysis of polycyclic aromatic hydrocarbons (PAHs) in soil and sediment. In this combination, the MMLLE unit serves as a trapping device for the extracted compounds. Simultaneously it cleans and concentrates the extract, which is then transferred on-line to the GC. No extra clean-up steps are required between the trapping and the transfer to GC. The on-line system gives excellent sensitivity while allowing small sample size. The method was linear, with limits of detection in the range 50-890 pg and limits of quantification 0.11-1.22 microg g(-1). The concentration enrichment factors obtained with the method ranged from 9 to 55. Comparison of the results with those obtained by other techniques confirmed the good performance.

  11. Analysis of Tocopherols by High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    B. Edison

    2009-01-01

    Full Text Available : Gas chromatography is the key technique for organic components and also for tocopherols analysis. High performance liquid chromatography has an important role to take part in applications such as the handling of less usual samples, prevention of degradation of heat sensitive functional groups and for micro preparative purposes. Many approaches for development of improved methods are suggested, especially for reversed phase applications.

  12. Antibiofilm activity of cashew juice pulp against Staphylococcus aureus, high performance liquid chromatography/diode array detection and gas chromatography-mass spectrometry analyses, and interference on antimicrobial drugs

    Directory of Open Access Journals (Sweden)

    Marcus V. Dias-Souza

    2017-07-01

    Full Text Available The epidemiology of Staphylococcus aureus infections has evolved in recent years, as this species is a major Gram-positive pathogen associated with healthcare services. The antimicrobial resistance of this species raises an urgent need for new treatment strategies. Fruits play important nutritional and economic roles in society, but their biological and pharmacological features are poorly explored when compared to nonedible parts of plants such as barks and leaves. In this study, we show that the cashew apple juice [cashew juice pulp (CJP] extract is active against the planktonic cells of S. aureus strains, and for the first time, we show that CJP is also active against S. aureus biofilms. High performance liquid chromatography and gas chromatography-mass spectrometry analyses were conducted to prospect for polyphenols and free carbohydrates, respectively. Cashew apple juice, which is rich in nutrients, is widely consumed in Brazil; therefore, the quality attributes of CJPs were investigated. Samples were evaluated for pH, total titratable acidity, vitamin C levels, and total soluble solids. We also detected an antagonistic interference of CJP when it was combined with different antimicrobial drugs.

  13. New Methodologies for Qualitative and Semi-Quantitative Determination of Carbon-Centered Free Radicals in Cigarette Smoke Using Liquid ChromatographyTandem Mass Spectrometry and Gas Chromatography-Mass Selective Detection

    Directory of Open Access Journals (Sweden)

    Gerardi AR

    2014-12-01

    Full Text Available Several approaches were explored to develop a high throughput procedure for relative determination of 14 different carbon-centered free radicals, both acyl and alkylaminocarbonyl type, in cigarette smoke. Two trapping procedures using 3-cyano-2,2,5,5-tetramethyl-1-pyrrolidinyloxy, or 3-cyanoproxyl radical (3-CNP were designed for this study: a trapping in solution and b trapping on a solid support which was a Cambridge filter pad. Fresh whole smoke and vapor phase smoke from mainstream cigarette smoke from Kentucky Reference Cigarettes 2R4F, as partitioned via an unadulterated Cambridge filter pad, were transferred into each trapping system in separate experiments. The 3-CNP coated Cambridge filter pad approach was shown to be superior to the impinger procedure as described in this study. Gas chromatography coupled with mass selective detection (GC-MS was employed for the first time as an alternate means of detecting several relatively highly concentrated radical adducts. Liquid chromatography tandem mass spectrometry (LC-MS/MS with precursor ion monitoring and selected ion monitoring (SIM was used for detecting the large array of radicals, including several not previously reported: formyl, crotonyl, acrolein, aminocarbonyl, and anilinocarbonyl radicals. Relative quantitation was achieved using as external calibration standards of 4-(1-pyrrolidinobenzaldehyde and nicotine. It was determined that the yield of carbon-centered free radicals by reference cigarette 2R4F was approximately 265 nmoles/cigarette at 35 mL puff/60 sec interval/2 sec duration smoking conditions.

  14. Antibiofilm activity of cashew juice pulp against Staphylococcus aureus, high performance liquid chromatography/diode array detection and gas chromatography-mass spectrometry analyses, and interference on antimicrobial drugs.

    Science.gov (United States)

    Dias-Souza, Marcus V; Dos Santos, Renan M; de Siqueira, Ezequias P; Ferreira-Marçal, Pedro H

    2017-07-01

    The epidemiology of Staphylococcus aureus infections has evolved in recent years, as this species is a major Gram-positive pathogen associated with healthcare services. The antimicrobial resistance of this species raises an urgent need for new treatment strategies. Fruits play important nutritional and economic roles in society, but their biological and pharmacological features are poorly explored when compared to nonedible parts of plants such as barks and leaves. In this study, we show that the cashew apple juice [cashew juice pulp (CJP)] extract is active against the planktonic cells of S. aureus strains, and for the first time, we show that CJP is also active against S. aureus biofilms. High performance liquid chromatography and gas chromatography-mass spectrometry analyses were conducted to prospect for polyphenols and free carbohydrates, respectively. Cashew apple juice, which is rich in nutrients, is widely consumed in Brazil; therefore, the quality attributes of CJPs were investigated. Samples were evaluated for pH, total titratable acidity, vitamin C levels, and total soluble solids. We also detected an antagonistic interference of CJP when it was combined with different antimicrobial drugs. Copyright © 2016. Published by Elsevier B.V.

  15. Development of a method based on on-line reversed phase liquid chromatography and gas chromatography coupled by means of an adsorption-desorption interface for the analysis of selected chiral volatile compounds in methyl jasmonate treated strawberries.

    Science.gov (United States)

    de la Peña Moreno, Fernando; Blanch, Gracia Patricia; Flores, Gema; Ruiz Del Castillo, Maria Luisa

    2010-02-12

    A method based on the use of the through oven transfer adsorption-desorption (TOTAD) interface in on-line coupling between reversed phase liquid chromatography and gas chromatography (RPLC-GC) for the determination of chiral volatile compounds was developed. In particular, the method was applied to the study of the influence of methyl jasmonate (MJ) treatment on the production and enantiomeric composition of selected aroma compounds in strawberry. The compounds studied were ethyl 2-methylbutanoate, linalool and 4-hydroxy-2,5-dimethyl-3(2H)-furanone (i.e. furaneol), which were examined on days 3, 6 and 9 after treatment. The method developed resulted in relative standard deviations (RSDs) of 21.6%, 8.1% and 9.8% and limits of detection (LD) of 0.04, 0.07 and 0.02mg/l for ethyl 2-methylbutanoate, linalool and furaneol, respectively. The application of the RPLC-TOTAD-GC method allowed higher levels of ethyl 2-methylbutanoate, linalool and furaneol to be detected, particularly after 9 days of treatment. Besides, MJ demonstrated to affect the enantiomeric distribution of ethyl 2-methylbutanoate. On the contrary, the enantiomeric composition of linalool and furaneol kept constant in both control and MJ-treated strawberries throughout the study. These results are discussed. Copyright 2009 Elsevier B.V. All rights reserved.

  16. Tissue-specific metabolite profiling of Cyperus rotundus L. rhizomes and (+)-nootkatone quantitation by laser microdissection, ultra-high-performance liquid chromatography-quadrupole time-of-flight mass spectrometry, and gas chromatography-mass spectrometry techniques.

    Science.gov (United States)

    Jaiswal, Yogini; Liang, Zhitao; Guo, Ping; Ho, Hing-Man; Chen, Hubiao; Zhao, Zhongzhen

    2014-07-23

    Cyperus rotundus L. is a plant species commonly found in both India and China. The caused destruction of this plant is of critical concern for agricultural produce. Nevertheless, it can serve as a potential source of the commercially important sesquiterpenoid (+)-nootkatone. The present work describes comparative metabolite profiling and (+)-nootkatone content determination in rhizome samples collected from these two countries. Laser dissected tissues, namely, the cortex, hypodermal fiber bundles, endodermis, amphivasal vascular bundles, and whole rhizomes were analyzed by ultra-high-performance liquid chromatography-quadrupole time-of-flight mass spectrometry (UHPLC-QTOF MS). Gas chromatography-mass spectrometry (GC-MS) analysis was used for profiling of essential oil constituents and quantitation of (+)-nootkatone. The content of (+)-nootkatone was found to be higher in samples from India (30.47 μg/10 g) compared to samples from China (21.72 μg/10 g). The method was validated as per International Conference on Harmonisation (ICH) guidelines (Q2 R1). The results from this study can be applied for quality control and efficient utilization of this terpenoid-rich plant for several applications in food-based industries.

  17. Miniaturised pressurised liquid extraction aromatic hydrocarbons from soil and sediment with subsequent large-volume injection-gas chromatography

    NARCIS (Netherlands)

    Ramos, L.; Vreuls, J.J.; Brinkman, U.A.T.

    2000-01-01

    Analyte extraction is the main limitation when developing at-line, or on-line, procedures for the preparation of (semi)solid environmental samples. Pressurised liquid extraction (PLE) is an analyte- and matrix-independent technique which provides cleaner extracts than the time-consuming classical

  18. UHPLC: The Greening Face of Liquid Chromatography

    OpenAIRE

    Cielecka-Piontek, Judyta; Zalewski, Przemys?aw; Jeli?ska, Anna; Garbacki, Piotr

    2013-01-01

    Pharmaceutical analysis based on chromatographic separation is an important part of studies aimed at developing routine quality analysis of drugs. High-performance liquid chromatography (HPLC) is one of the main analytical techniques recommended for drug analysis. Although it meets many criteria vital for analysis, it is time-consuming and uses a relatively high amount of organic solvents compared to other analytical techniques. Recently, Ultra-high-performance liquid chromatography (UHPLC) h...

  19. Activity coefficients at infinite dilution of organic solutes in the ionic liquid trihexyl(tetradecyl)phosphonium tetrafluoroborate using gas-liquid chromatography at T = (313.15, 333.15, 353.15, and 373.15) K

    International Nuclear Information System (INIS)

    Tumba, Kaniki; Reddy, Prashant; Naidoo, Paramespri; Ramjugernath, Deresh

    2011-01-01

    Research highlights: → Activity coefficients at infinite dilution in the ionic liquid [3C 6 C 14 P][BF 4 ]. → Twenty-seven solutes investigated at T = (313.15, 333.15, 353.15, and 373.15) K. → [3C 6 C 14 P][BF 4 ] shows promise for the separation of aromatic and alcohol mixtures. - Abstract: Activity coefficients at infinite dilution have been measured by gas-liquid chromatography for 27 organic solutes (n-alkanes, 1-alkenes, 1-alkynes, cycloalkanes, aromatics, alcohols, and ketones) in the ionic liquid trihexyl(tetradecyl)phosphonium tetrafluoroborate [3C 6 C 14 P][BF 4 ]. The measurements were carried out at four different temperatures viz.T = (313.15, 333.15, 353.15, and 373.15) K. From the experimental data, partial molar excess enthalpy values at infinite dilution were calculated for the experimental temperature range. The selectivity values for the separation of n-hexane/benzene, cyclohexane/benzene, and methanol/benzene mixtures were determined from the experimental infinite dilution activity coefficient values. These values were compared to those available in the literature for other ionic liquids and commercial solvents, so as to assess the feasibility of employing [3C 6 C 14 P][BF 4 ] in solvent-enhanced industrial separations.

  20. Air-assisted liquid-liquid microextraction-gas chromatography-flame ionisation detection: a fast and simple method for the assessment of triazole pesticides residues in surface water, cucumber, tomato and grape juices samples.

    Science.gov (United States)

    Farajzadeh, Mir Ali; Khoshmaram, Leila

    2013-12-01

    A recently reported microextraction technique namely air-assisted liquid-liquid microextraction (AALLME) has been described for the extraction/preconcentration of some triazole pesticides from different samples prior to gas chromatography-flame ionisation detection (GC-FID). This technique is similar to dispersive liquid-liquid microextraction (DLLME) but in this method there is no need to use a disperser solvent and also volume of the used extraction solvent is less than DLLME. In this study, toluene with a density lower than that of water was used as an extraction solvent. Under the optimum extraction conditions, the method showed wide linear ranges with R(2)>0.996 and low limits of detection and quantification between 0.53-1.13 and 1.76-3.77 ng mL(-1), respectively. Enrichment factors (EFs) and extraction recoveries (ERs) were in the ranges of 713-808 and 100-113%, respectively. Relative standard deviations (RSDs) for the extraction of 25 and 250 ng mL(-1) of each selected triazole pesticide were less than 7% for intra-day (n=6) and inter-days (n=5) precision. The method was successfully used for analytes determination in different surface water, grape juice, cucumber, and tomato samples. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Determination of phthalic acid esters in water samples by hollow fiber liquid-phase microextraction prior to gas chromatography tandem mass spectrometry.

    Science.gov (United States)

    González-Sálamo, Javier; González-Curbelo, Miguel Ángel; Socas-Rodríguez, Bárbara; Hernández-Borges, Javier; Rodríguez-Delgado, Miguel Ángel

    2018-06-01

    A new hollow fiber liquid-phase microextraction (HF-LPME) method has been developed for the extraction of a group of phthalic acid esters (PAEs) of interest from different water samples prior to gas chromatography tandem mass spectrometry analysis. HF-LPME was carried out using 1-octanol as extraction solvent followed by a back extraction step with cyclohexane. The different parameters that affect HF-LPME such as sample pH, ionic strength, extraction time, stirring rate, extraction temperature and back extraction conditions were investigated. The optimized conditions involved the extraction of 10 mL of sample without pH adjustment or addition of salt during 75 min under a stirring of 850 rpm at 60 °C and subsequent desorption with 200 μL of cyclohexane for 10 min in an ultrasonic bath. The method was validated in terms of calibration and recovery studies using dibutyl phthalate-d 4 as internal standard. The developed procedure gave satisfactory recovery (74-120%) and relative standard deviation values (<20%) for the studied PAEs in mineral, tap, pond and waste water samples. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Combination of liquid-phase hollow fiber membrane microextraction with gas chromatography-negative chemical ionization mass spectrometry for the determination of dichlorophenol isomers in water and urine.

    Science.gov (United States)

    Lai, Bin-Wei; Liu, Bo-Min; Malik, Pradip K; Wu, Hui-Fen

    2006-08-18

    A method for the determination of trace amount of dichlorophenol isomers in urine samples using the combination of liquid-phase hollow fiber microextraction (LPME-HF) with gas chromatography-negative chemical ionization mass spectrometry (GC-NCI-MS) has been demonstrated. The method has been optimized with respect to several parameters including the effects of negative chemical ionization (NCI) reagent pressure, the hollow fiber length, extraction time, stirring rate, sample pH and salt concentration for the determination of dichlorophenol isomers in water. The correlation coefficient (r2) of the calibration curves for 2,5-dichlorophenol, 2,3-dichlorophenol, 2,6-dichlorophenol, 3,5-dichlorophenol and 3,4-dichlorophenol were 0.988, 0.981, 0.985, 0.971 and 0.994, respectively. The average recovery rates for 2,5-dichlorophenol, 2,3-dichlorophenol, 2,6-dichlorophenol, 3,5-dichlorophenol and 3,4-dichlorophenol were 0.97, 0.93, 0.96, 0.95 and 0.95, respectively (n=3 for each dichlorophenol) indicate that the methodology is feasible for the determination of trace amounts of dichlorophenol isomers in water and urine samples. Limits of detection (LOD) have been found to be in the range of 5-20 ng/ml. In addition, differentiation of the five dichlorophenol isomers is an easy task using the current approach of combining LPME-HF with NCI-GC-MS technique since they exhibit different NCI spectra.

  3. Miniaturized hollow fiber assisted liquid-phase microextraction with in situ derivatization and gas chromatography-mass spectrometry for analysis of bisphenol A in human urine sample.

    Science.gov (United States)

    Kawaguchi, Migaku; Ito, Rie; Okanouchi, Noriya; Saito, Koichi; Nakazawa, Hiroyuki

    2008-07-01

    A new method that involves miniaturized hollow fiber assisted liquid-phase microextraction (HF-LPME) with in situ derivatization and gas chromatography-mass spectrometry (GC-MS) is described for the determination of trace amounts of bisphenol A (BPA) in human urine samples. The detection limit and the quantification limit of BPA in human urine sample are 0.02 and 0.1 ng ml(-1) (ppb), respectively. The calibration curve for BPA is linear with a correlation coefficient of >0.999 in the range of 0.1-50 ng ml(-1). The average recoveries of BPA in human urine samples spiked with 1 and 5 ng ml(-1) BPA are 101.0 (R.S.D.: 6.7%) and 98.8 (R.S.D.: 1.8%), respectively, with correction using the added surrogate standard, bisphenol A-(13)C12. This simple, accurate, sensitive and selective analytical method can be applicable to the determination of trace amounts of BPA in human urine samples.

  4. Miniaturized hollow fiber assisted liquid-phase microextraction and gas chromatography-mass spectrometry for determination of benzophenone and derivates in human urine sample.

    Science.gov (United States)

    Kawaguchi, Migaku; Ito, Rie; Honda, Hidehiro; Koganei, Youji; Okanouchi, Noriya; Saito, Koichi; Seto, Yasuo; Nakazawa, Hiroyuki

    2009-01-15

    The determination of benzophenones (BPs) in human urine sample by miniaturized hollow fiber assisted liquid-phase microextraction (HF-LPME) and gas chromatography-mass spectrometry (GC-MS) is described. As analytes, BP, its metabolites benzhydrol (BP-OH) and 2-hydroxybenzophenone (2OH-BP), and its derivatives 2-hydroxy-4-methoxybenzophenone (BP-3) and 2-hydroxy-4-methoxy-4'-methylbenzophenone (BP-10) were selected. The detection limit and the quantification limit of BPs in human urine sample are 5-10 and 20-50 pg mL(-1), respectively. The calibration curve for BPs is linear with correlation coefficient higher than 0.99 in the range of 0.02-10 or 0.05-10 ng mL(-1). The average recoveries of BPs in human urine samples spiked with 0.5 and 5 ng mL(-1) BPs are 89.8-100.2% (RSD: 2.5-9.3%) and 89.3-99.9% (RSD: 2.9-3.7%), respectively. Ten human urine samples were analyzed using the present method. BP-OH and BP-3 were detected in all the samples within the range of 0.24-5.91 and 0.43-5.17 ng mL(-1), respectively. This simple, sensitive, and selective analytical method was successfully applied to the determination of trace amounts of BPs in human urine samples.

  5. Hollow-fiber-supported liquid phase microextraction with in situ derivatization and gas chromatography-mass spectrometry for determination of chlorophenols in human urine samples.

    Science.gov (United States)

    Ito, Rie; Kawaguchi, Migaku; Honda, Hidehiro; Koganei, Youji; Okanouchi, Noriya; Sakui, Norihiro; Saito, Koichi; Nakazawa, Hiroyuki

    2008-09-01

    A simple and highly sensitive method that involves hollow-fiber-supported liquid phase microextraction (HF-LPME) with in situ derivatization and gas chromatography-mass spectrometry (GC-MS) was developed for the determination of chlorophenols (CPs) such as 2,4-dichlorophenol (DCP), 2,4,6-trichlorophenol (TrCP), 2,3,4,6-tetrachlorophenol (TeCP) and pentachlorophenol (PCP) in human urine samples. Human urine samples were enzymatically de-conjugated with beta-glucuronidase and sulfatase. After de-conjugation, HF-LPME with in situ derivatization was performed. After extraction, 2 microl of extract was carefully withdrawn into a syringe and injected into the GC-MS system. The limits of detection (S/N=3) and quantification (S/N>10) of CPs in the human urine samples are 0.1-0.2 ng ml(-1) and 0.5-1 ng ml(-1), respectively. The calibration curve for CPs is linear with a correlation coefficient of >0.99 in the range of 0.5-500 ng ml(-1) for DCP and TrCP, and of 1-500 ng ml(-1) for TeCP and PCP, respectively. The average recoveries of CPs (n=6) in human urine samples are 81.0-104.0% (R.S.D.: 1.9-6.6%) with correction using added surrogate standards. When the proposed method was applied to human urine samples, CPs were detected at sub-ng ml(-1) level.

  6. Fully automated dynamic in-syringe liquid-phase microextraction and on-column derivatization of carbamate pesticides with gas chromatography/mass spectrometric analysis.

    Science.gov (United States)

    Lee, Jingyi; Lee, Hian Kee

    2011-09-01

    A new fully automated dynamic in-syringe liquid-phase microextraction (LPME) and on-column derivatization approach, with gas chromatography/mass spectrometric (GC/MS) analysis, was developed to determine carbamate pesticides from water samples. With the use of a CTC CombiPal autosampler and its associated Cycle Composer software, a sample preparation-GC/MS method was enabled that allowed sample extraction, extract injection, and analyte derivatization to be carried out completely automatically. Optimization of extraction parameters was carried out by orthogonal array design which required a minimum of 16 experiments; the entire set of experiments was performed completely automatically and consecutively without any human intervention. Low limits of detection ranging from 0.05 to 0.1 μg/L were achieved for the carbamates. Effective enrichment of the analytes at a low concentration of 0.01 mg/L was also achieved (enrichment factors of between 57 and 138). The precision of the optimized method was satisfactory, with relative standard deviations of <6.0% (n = 6). High relative recoveries of between 81 and 125% were obtained when the method was applied to the analysis of real water samples, indicating that the sample matrix had little effect on the developed method. This automated dynamic in-syringe LPME approach demonstrated the feasibility of a complete analytical system comprising sample preparation and GC/MS that might be operated onsite, fully automatically without human intervention.

  7. An uncooked vegan diet shifts the profile of human fecal microflora: computerized analysis of direct stool sample gas-liquid chromatography profiles of bacterial cellular fatty acids.

    Science.gov (United States)

    Peltonen, R; Ling, W H; Hänninen, O; Eerola, E

    1992-01-01

    The effect of an uncooked extreme vegan diet on fecal microflora was studied by direct stool sample gas-liquid chromatography (GLC) of bacterial cellular fatty acids and by quantitative bacterial culture by using classical microbiological techniques of isolation, identification, and enumeration of different bacterial species. Eighteen volunteers were divided randomly into two groups. The test group received an uncooked vegan diet for 1 month and a conventional diet of mixed Western type for the other month of the study. The control group consumed a conventional diet throughout the study period. Stool samples were collected. Bacterial cellular fatty acids were extracted directly from the stool samples and measured by GLC. Computerized analysis of the resulting fatty acid profiles was performed. Such a profile represents all bacterial cellular fatty acids in a sample and thus reflects its microflora and can be used to detect changes, differences, or similarities of bacterial flora between individual samples or sample groups. GLC profiles changed significantly in the test group after the induction and discontinuation of the vegan diet but not in the control group at any time, whereas quantitative bacterial culture did not detect any significant change in fecal bacteriology in either of the groups. The results suggest that an uncooked extreme vegan diet alters the fecal bacterial flora significantly when it is measured by direct stool sample GLC of bacterial fatty acids. PMID:1482187

  8. Multiresidue analysis of acidic and polar organic contaminants in water samples by stir-bar sorptive extraction-liquid desorption-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Quintana, José Benito; Rodil, Rosario; Muniategui-Lorenzo, Soledad; López-Mahía, Purificación; Prada-Rodríguez, Darío

    2007-12-07

    The feasibility of stir-bar sorptive extraction (SBSE) followed by liquid desorption in combination with large volume injection (LVI)-in port silylation and gas chromatography-mass spectrometry (GC-MS) for the simultaneous determination of a broad range of 46 acidic and polar organic pollutants in water samples has been evaluated. The target analytes included phenols (nitrophenols, chlorophenols, bromophenols and alkylphenols), acidic herbicides (phenoxy acids and dicamba) and several pharmaceuticals. Experimental variables affecting derivatisation yield and peak shape as a function of different experimental PTV parameters [initial injection time, pressure and temperature and the ratio solvent volume/N-(tert-butyldimethylsilyl)-N-methyltrifluoroacetamide (MTBSTFA) volume] were first optimised by an experimental design approach. Subsequently, SBSE conditions, such as pH, ionic strength, agitation speed and extraction time were investigated. After optimisation, the method failed only for the extraction of most polar phenols and some pharmaceuticals, being suitable for the determination of 37 (out of 46) pollutants, with detection limits for these analytes ranging between 1 and 800 ng/L and being lower than 25 ng/L in most cases. Finally, the developed method was validated and applied to the determination of target analytes in various aqueous environmental matrices, including ground, river and wastewater. Acceptable accuracy (70-130%) and precision values (effects. Among the drawbacks of the method, carryover was identified as the main problem even though the Twisters were cleaned repeatedly.

  9. Determination of phthalates and organophosphate esters in particulated material from harbour air samples by pressurised liquid extraction and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Aragón, M; Marcé, R M; Borrull, F

    2012-11-15

    A method based on gas chromatography-mass spectrometry (GC-MS) combined with a pressurised liquid extraction (PLE) to determine four organophosphates, seven phthalate esters and bis(2-ethylhexyl) adipate in particulated material of harbour air samples has been developed. Some studies show that these compounds may cause hormone disrupting effects on human health. Moreover, the U.S. Environmental Protection Agency (EPA) has classified benzyl butyl phthalate and di(2-ethylhexyl) phthalate as possible human carcinogens.The chromatographic time per run analysis is less than 15 min and the complete separation of all compounds is achieved. The PLE was optimised with recoveries above 90% and the repeatability of the method with real samples is less than 11% (%RSD, n=4). The MDLs (0.004-0.4 ng m(-3)) and MQLs (0.02-2 ng m(-3)) are limited by the fact of some compounds are present in low levels in sampling blank filters.The method was successfully applied in several samples and most of the compounds under study were found. The most relevant values were the high concentration of di-iso-butyl phthalate (between 28 and 529 ng m(-3)) and the significant concentration of di(2-ethylhexyl) phthalate (between MQL and 22 ng m(-3)). In addition, benzyl butyl phthalate was also detected in some samples but at low concentration levels (between MQL to 0.2 ng m(-3)). Copyright © 2012 Elsevier B.V. All rights reserved.

  10. Study the Photochemical of Fragrance Allergens of Eugenol Derivatives in Commercial Essential Oils and Containing Clove Drugs Using Gas Chromatography and Liquid Chromatography-Mass Spectrometry

    OpenAIRE

    Lai-Hao Wang; Yu-Yo Lin; Jhih-Cheng Chen

    2016-01-01

    Screening the content of fragrance allergens (citral, geraniol, trans-cinnamaldehyde, hydroxycitronellal, cinnamyl alcohol, eugenol, dihydrocoumarin, methyl eugenol, iso-eugenol, coumarin, eugeyl acetate, α-hexylcinnamadehyde) in commercial essential oils and containing essential oil drugs has been using a gas chromatographic method. We selected 7 essential oils based on eugenol Derivatives for more content and can be used to process photo-irradiation. Comparision with results of photochemica...

  11. Programmed temperature vaporizing injector to filter off disturbing high boiling and involatile material for on-line high performance liquid chromatography gas chromatography with on-column transfer.

    Science.gov (United States)

    Biedermann, Maurus; Grob, Koni

    2013-03-15

    Insertion of a programmed temperature vaporizing (PTV) injector under conditions of concurrent solvent recondensation (CSR) into the on-line HPLC-GC interface for on-column transfer (such as the retention gap technique with partially concurrent eluent evaporation) enables filtering off high boiling or involatile sample constituents by a desorption temperature adjusted to the required cut-off. Details of this technique were investigated and optimized. Memory effects, observed when transferred liquid was sucked backwards between the transfer line and the wall of the injector liner, can be kept low by a small purge flow rate through the transfer line at the end of the transfer and the release of the liquid through a narrow bore capillary kept away from the liner wall. The column entrance should be within the well heated zone of the injector to prevent losses of solute material retained on the liner wall during the splitless period. The desorption temperature must be maintained until an elevated oven temperature is reached to prevent peak broadening resulting of a cool inlet section in the bottom part of the injector. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Indirect Determination of Vapor Pressures by Capillary Gas-Liquid Chromatography: Analysis of the Reference Vapor-Pressure Data and Their Treatment

    Czech Academy of Sciences Publication Activity Database

    Růžička, K.; Koutek, Bohumír; Fulem, M.; Hoskovec, Michal

    2012-01-01

    Roč. 57, č. 5 (2012), s. 1349-1368 ISSN 0021-9568 R&D Projects: GA ČR GA203/09/1327 Institutional research plan: CEZ:AV0Z40550506 Keywords : vapor pressures * capillary gas–liquid chromatography * reference data * relative retention time Subject RIV: CC - Organic Chemistry Impact factor: 2.004, year: 2012

  13. Fractionation of fecal neutral steroids by high performance liquid chromatography

    International Nuclear Information System (INIS)

    Jackson, E.M.; Kloss, C.A.; Weintraub, S.T.; Mott, G.E.

    1985-01-01

    Fecal neutral steroids were fractionated by high performance liquid chromatography (HPLC) into three major fractions: 5 beta-H, 3-keto steroids; 5 beta-H, 3 beta-hydroxy steroids; and 5 alpha-H and delta 5-3 beta-hydroxy steroids. This separation was achieved in about 10 minutes, with greater than 97% recovery of standards in each fraction. Gas-liquid chromatographic quantitation of fecal steroids fractionated by either HPLC or thin-layer chromatography gave nearly identical results. A method using both C18 reverse phase and silica HPLC to purify radiolabeled sterols is also described

  14. Development and Validation of Liquid Chromatography- Mass ...

    African Journals Online (AJOL)

    HP

    Purpose: To determine naproxen levels in human plasma using a new liquid chromatography-Mass spectroscopy/Mass spectroscopy (LC-MS/MS) method that involves a simple and single step extraction procedure using low-cost reagents. Method: A novel liquid chromatography–tandem mass spectrometry method for the ...

  15. Study of radiolysis products of natural organic materials by means of gas chromatography

    International Nuclear Information System (INIS)

    Pogocki, D.

    1994-01-01

    Analytical methods based on gas chromatography for identification determination of products arising during food irradiation have been presented. Behind the classics version of the methods one has shown also combined methods being the on-line connection of gas chromatography with mass spectroscopy as well as gas chromatography with liquid chromatography and mass spectroscopy. The applicability as well as weakness and advantages of each version have been discussed on the context of food irradiation. 11 refs, 7 figs

  16. Comparative evaluation of liquid-liquid extraction, solid-phase extraction and solid-phase microextraction for the gas chromatography-mass spectrometry determination of multiclass priority organic contaminants in wastewater.

    Science.gov (United States)

    Robles-Molina, José; Gilbert-López, Bienvenida; García-Reyes, Juan F; Molina-Díaz, Antonio

    2013-12-15

    The European Water Framework Directive (WFD) 2000/60/EC establishes guidelines to control the pollution of surface water by sorting out a list of priority substances that involves a significant risk to or via the aquatic systems. In this article, the analytical performance of three different sample preparation methodologies for the GC-MS/MS determination of multiclass organic contaminants-including priority comprounds from the WFD-in wastewater samples using gas chromatography-mass spectrometry was evaluated. The methodologies tested were: (a) liquid-liquid extraction (LLE) with n-hexane; (b) solid-phase extraction (SPE) with C18 cartridges and elution with ethyl acetate:dichloromethane (1:1 (v/v)), and (c) headspace solid-phase microextraction (HS-SPME) using two different fibers: polyacrylate and polydimethylsiloxane/carboxen/divinilbenzene. Identification and confirmation of the selected 57 compounds included in the study (comprising polycyclic aromatic hydrocarbons (PAHs), pesticides and other contaminants) were accomplished using gas chromatography tandem mass spectrometry (GC-MS/MS) with a triple quadrupole instrument operated in the multiple reaction monitoring (MRM) mode. Three MS/MS transitions were selected for unambiguous confirmation of the target chemicals. The different advantages and pitfalls of each method were discussed. In the case of both LLE and SPE procedures, the method was validated at two different concentration levels (15 and 150 ng L(-1)) obtaining recovery rates in the range 70-120% for most of the target compounds. In terms of analyte coverage, results with HS-SPME were not satisfactory, since 14 of the compounds tested were not properly recovered and the overall performance was worse than the other two methods tested. LLE, SPE and HS-SPME (using polyacrylate fiber) procedures also showed good linearity and precision. Using any of the three methodologies tested, limits of quantitation obtained for most of the detected compounds were in

  17. Determination of nitrosamines and caffeine metabolites in wastewaters using gas chromatography mass spectrometry and ionic liquid stationary phases.

    Science.gov (United States)

    Reyes-Contreras, Carolina; Domínguez, Carmen; Bayona, Josep M

    2012-10-26

    Recently, the interest to assess the environmental and human health effects of a wide group of emerging contaminants is growing worldwide. However, one of the main problems associated to their exposure is their determination in environmental matrices. It is hindered by the high polarity of most of these analytes, the poor selectivity obtained with low polarity stationary phases and the high background obtained with polar columns commonly used in GC-MS. Accordingly, this study examines the suitability of ionic liquid (IL) (e.g. SLB-IL59, SLB-IL61, SLB-IL82 and SLB-IL111) as stationary phases for GC-MS and their application to the determination of nitrosamines and caffeine metabolites in wastewater samples. Different chromatographic conditions were evaluated and results discussed in terms of resolution and peak symmetry. The SLB-IL111 column enabled the baseline separation and quantification of 7 nitrosamines in a shorter analysis time compared with cyanopropylphenyl polysiloxane commonly used. On the other hand, the SLB-IL59 column provided the best results for caffeine metabolites. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. Determination of basic azaarenes and polynuclear aromatic hydrocarbons in airborne particulate matter by gas chromatography

    DEFF Research Database (Denmark)

    Nielsen, Torben; Clausen, Peraxel; Jensen, Finn Palmgren

    1986-01-01

    phase (adjusted to pH 14 with potassium hydroxide) with dichloromethane, and determined by capillary gas chromatography (g.c.) with a nitrogen-sensitive detector. The PAH in the toluene phase are isolated by means of semipreparative high-performance liquid chromatography and liquid-liquid extraction...

  19. Comparative gas chromatography-mass spectroscopy, Fourier transform infrared spectroscopy, and high-performance liquid chromatography analysis of essential oils extracted using 4 methods from the leaves of Eucalyptus globulus L.

    Directory of Open Access Journals (Sweden)

    Yasmeen Khan

    2016-01-01

    Full Text Available Background: Eucalyptus globulus L. (family, Myrtaceae is one of the world′s most widely planted genera. E. globulus L., commonly referred to as Tasmanian blue gum, is a fast growing, evergreen tree, native to Tasmania and South-East Australia. Apart from its extensive use in pulp industry, it is also produces Oleum Eucalypti (eucalyptus oil that is extracted on commercial scale in many countries such as China, India, South Africa, Portugal, Brazil, and Tasmania, as a raw material in perfumery, cosmetics, food beverage, aromatherapy, and phytotherapy. Materials and Methods: Traditional hydrodistillation (HD, solvent extraction (SE, ultrasonication (US, and supercritical fluid extraction (SFE were conducted for the extraction of essential oil from the leaves of E. globulus. Each oil was evaluated in terms of high-performance liquid chromatography (HPTLC and Fourier transform infrared spectroscopy (FTIR fingerprinting with qualitative and semi-quantitative composition of the isolated essential oil by gas chromatography-mass spectroscopy (GCMS, the extract yield of essential oil was 2.60%, 2.2%, 2.0%, and 3.6% v/w, respectively, for HD, SE, US, and SFE. Results: A total of 53 compounds were identified by GCMS. Comparative analysis indicated that SFE was favorable for extraction of monoterpene hydrocarbon, sesquiterpene hydrocarbon, and oxygenated sesquiterpene hydrocarbon. HD, SE, and US had certain advantages in the extraction of aliphatic saturated hydrocarbons organic acid and esters. Overlay, FTIR spectra of oil samples obtained by four extraction methods were superimposed with each other showing similar components. The maximum separation of compound seen at 254 nm and lesser at 366 nm by HPTLC fingerprinting which again showed superimposed chromatograms. Conclusion: It is concluded that different extraction method may lead to different yields of essential oils where the choice of appropriate method is very important to obtained more desired

  20. Determination of acrylamide in Chinese traditional carbohydrate-rich foods using gas chromatography with micro-electron capture detector and isotope dilution liquid chromatography combined with electrospray ionization tandem mass spectrometry

    International Nuclear Information System (INIS)

    Zhang Yu; Ren Yiping; Zhao Hangmei; Zhang Ying

    2007-01-01

    The present study developed two analytical methods for quantification of acrylamide in complex food matrixes, such as Chinese traditional carbohydrate-rich foods. One is based on derivatization with potassium bromate and potassium bromide without clean-up prior to gas chromatography with micro-electron capture detector (GC-MECD). Alternatively, the underivatized acrylamide was detected by high-performance liquid chromatography coupled to quadrupole tandem mass spectrometry (HPLC-MS/MS) in the positive electrospray ionization mode. For both methods, the Chinese carbohydrate-rich samples were homogenized, defatted with petroleum ether and extracted with aqueous solution of sodium chloride. Recovery rates for acrylamide from spiked Chinese style foods with the spiking level of 50, 500 and 1000 μg kg -1 were in the range of 79-93% for the GC-MECD including derivatization and 84-97% for the HPLC-MS/MS method. Typical quantification limits of the HPLC-MSMS method were 4 μg kg -1 for acrylamide. The GC-MECD method achieved quantification limits of 10 μg kg -1 in Chinese style foods. Thirty-eight Chinese traditional foods purchased from different manufacturers were analyzed and compared with four Western style foods. Acrylamide contaminant was found in all of samples at the concentration up to 771.1 and 734.5 μg kg -1 detected by the GC and HPLC method, respectively. The concentrations determined with the two different quantitative methods corresponded well with each other. A convenient and fast pretreatment procedure will be optimized in order to satisfy further investigation of hundreds of samples

  1. One- and two-dimensional gas chromatography-mass spectrometry and high performance liquid chromatography-diode-array detector fingerprints of complex substances: a comparison of classification performance of similar, complex Rhizoma Curcumae samples with the aid of chemometrics.

    Science.gov (United States)

    Ni, Yongnian; Mei, Minghua; Kokot, Serge

    2012-01-27

    Many complex natural or synthetic products are analysed either by the GC-MS (gas chromatography-mass spectrometry) or HPLC-DAD (high performance liquid chromatography-diode-array detector) technique, each of which produces a one-dimensional fingerprint for a given sample. This may be used for classification of different batches of a product. GC-MS and HPLC-DAD analyses of complex, similar substances represented by the three common types of the TCM (traditional Chinese medicine), Rhizoma Curcumae were analysed in the form of one- and two-dimensional matrices firstly with the use of PCA (Principal component analysis), which showed a reasonable separation of the samples for each technique. However, the separation patterns were rather different for each analytical method, and PCA of the combined data matrix showed improved discrimination of the three types of object; close associations between the GC-MS and HPLC-DAD variables were observed. LDA (linear discriminant analysis), BP-ANN (back propagation-artificial neural networks) and LS-SVM (least squares-support vector machine) chemometrics methods were then applied to classify the training and prediction sets. For one-dimensional matrices, all training models indicated that several samples would be misclassified; the same was observed for each prediction set. However, by comparison, in the analysis of the combined matrix, all models gave 100% classification with the training set, and the LS-SVM calibration also produced a 100% result for prediction, with the BP-ANN calibration closely behind. This has important implications for comparing complex substances such as the TCMs because clearly the one-dimensional data matrices alone produce inferior results for training and prediction as compared to the combined data matrix models. Thus, product samples may be misclassified with the use of the one-dimensional data because of insufficient information. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. Deep eutectic solvent based gas-assisted dispersive liquid-phase microextraction combined with gas chromatography and flame ionization detection for the determination of some pesticide residues in fruit and vegetable samples.

    Science.gov (United States)

    Farajzadeh, Mir Ali; Sattari Dabbagh, Masoumeh; Yadeghari, Adeleh

    2017-05-01

    In this study, a gas-assisted dispersive liquid-phase microextraction method using a deep eutectic solvent as the extraction solvent combined with gas chromatography and flame ionization detection was developed for the extraction and determination of some pesticide residues in vegetable and fruit juice samples. In this method, choline chloride and 4-chlorophenol at a molar ratio of 1:2 were mixed. By heating and vortexing, a clear, water-immiscible, and homogeneous liquid was formed. The obtained deep eutectic solvent was added to an aqueous solution of the analytes in a conical test tube. Air was bubbled into the aqueous solution and a cloudy solution was obtained. During this step, the analytes were extracted into the fine droplets of the extraction solvent. After centrifugation, an aliquot of the settled phase was injected into the separation system. Under the optimum extraction conditions, enrichment factors, and extraction recoveries were obtained in the ranges of 247-355 and 49-71%, respectively. The obtained values for the limits of detection and quantification were in the ranges of 0.24-1.4 and 0.71-4.2 μg/L, respectively. The proposed method is simple, fast, efficient, and inexpensive. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Comparison of solid phase microextraction and hollow fiber liquid phase microextraction for the determination of pesticides in aqueous samples by gas chromatography triple quadrupole tandem mass spectrometry.

    Science.gov (United States)

    Garrido Frenich, Antonia; Romero-González, R; Martínez Vidal, José Luis; Martínez Ocaña, R; Baquero Feria, P

    2011-02-01

    This work compares two miniaturised sample preparation methods, solid phase microextraction (SPME) and hollow fiber liquid phase microextraction (HF-LPME), in combination with gas chromatography coupled to tandem mass spectrometry with a triple quadrupole analyzer for the determination of 77 pesticides in drinking water. In the case of SPME, extraction temperature and time were optimized by experimental design, although other parameters, as desorption time, pH, and ionic strength, were also evaluated. The extraction and desorption solvents [octanol/dihexyl ether (75:25, v/v) and cyclohexane, respectively], as well as the extraction and desorption time, ionic strength, and pH, were studied for the HF-LPME procedure. Under the optimal conditions, recoveries (70.2-113.5% for SPME and 70.0-119.5% for HF-LPME), intra-day precision (2.1-19.4% for SPME and 4.3-22.5% for HF-LPME), inter-day precision (5.2-21.5% for SPME and 8.4-27.3% for HF-LPME), and limits of detection, between 0.1 and 28.8 ng/L for SPME and 0.2 and 47.1 ng/L for HF-LPME and overall uncertainty (9.6-25.2% for SPME and 13.3-27.5% for HF-LPME) were established for both extraction procedures. Finally, the proposed methods were successfully applied to the analysis of 41 drinking water samples, and similar results were obtained with both extraction approaches.

  4. Separation and determination of seleno amino acids using gas chromatography hyphenated with inductively coupled plasma mass spectrometry after hollow fiber liquid phase microextraction.

    Science.gov (United States)

    Duan, Jiankun; Hu, Bin

    2009-05-01

    A new derivatization-extraction method for preconcentration of seleno amino acids using hollow fiber liquid phase microextraction (HF-LPME) was developed for the separation and determination of seleno amino acids in biological samples by gas chromatography-inductively coupled plasma mass spectrometry (GC-ICP-MS). Derivatization was performed with ethyl chloroformate (ECF) to improve the volatility of seleno amino acids. Parameters influencing microextraction, including extraction solvent, pH of sample solution, extraction time, stirring speed, and inorganic salt concentration have been investigated. Under the optimal conditions, the limits of detection (LODs) obtained for Se-methyl-selenocysteine (SeMeCys), selenomethionine (SeMet), and selenoethionine (SeEth) were 23, 15, and 11 ng Se l(-1), respectively. The relative standard deviations (RSDs) were 14.6%, 16.4%, and 19.4% for SeMeCys, SeMet, and SeEth (c = 1.0 ng ml(-1), n = 7), respectively, and the RSDs for SeMeCys, SeMet could be improved obviously if SeEth was utilized as the internal standard. The proposed method was applied for the determination of seleno amino acids in extracts of garlic, cabbage, and mushroom samples, and the recoveries for the spiked samples were in the range of 96.8-108% and 93.4-115% with and without the use of SeEth as internal standard. The developed method was also applied to the analysis of SeMet in a certified reference material of SELM-1 yeast and the determined value is in good agreement with the certified value. 2008 John Wiley & Sons, Ltd.

  5. Investigation of bioaccumulation profile of oestrogens in zebrafish liver by hollow fibre protected liquid phase microextraction with gas chromatography-mass spectrometric detection.

    Science.gov (United States)

    Kanimozhi, Sivarajan; Basheer, Chanbasha; Neveliappan, Shanmugam; Ang, Kelvin; Xue, Feng; Lee, Hian Kee

    2012-11-15

    The applicability of hollow fibre protected liquid phase microextraction (HF-LPME) for the determination of three oestrogens, namely estrone (E1), 17β-estradiol (E2) and 17α-ethinylestradiol (EE2) from individual zebrafish liver samples, in a bioaccumulation study on these organisms, is reported. The oestrogens were extracted from single, mechanically crushed and minced livers from fish that were heaved in tubes containing water spiked at low concentration of the analytes. Extraction was performed with ∼3 μL of toluene contained in the hollow fibre. In order to achieve high extraction efficiency, the parameters that could affect the effectiveness of HF-LPME were optimized, i.e. the extracting organic solvent, extraction time, stirring speed and pH of the aqueous phase. For gas chromatography/mass spectrometry (GC/MS) analysis, injection port derivatization of the oestrogens with bis(trimethylsilyl)trifluoroacetamide was conducted. Under the most favourable extraction and derivatization conditions, enrichment factors of 158-279 were obtained. Linearity of the HF-LPME-GC/MS method was evaluated from 1 to 50 μg/L and the coefficient of determination (r²) ranged from 0.9687 to 0.9926. The LODs were between 0.017 and 0.033 μg/L (at a signal to noise ratio of 3) with relative standard deviations (RSDs, analytes spiked at 5 μg/L) of between 15 and 17% (n=3). Copyright © 2012 Elsevier B.V. All rights reserved.

  6. Determination of pyrethroid metabolites in human urine using liquid phase microextraction coupled in-syringe derivatization followed by gas chromatography/electron capture detection.

    Science.gov (United States)

    Lin, Chiu-Hwa; Yan, Cheing-Tong; Kumar, Ponnusamy Vinoth; Li, Hong-Ping; Jen, Jen-Fon

    2011-08-01

    Metabolites of synthetic pyrethroids such as cis-3-(2,2-dibromovinyl)-2,2-di-methylcyclo-propane-1-carboxylic acid, cis- and trans-3-(2,2-dichlorovinyl)-2,2-dimethylcyclopropane-1-carboxylic acid), 3-phenoxybenzoic acid (3-PBA), and 4-fluoro-3-PBA are biomarkers for exposure to phenothrin, tetramethrin, cyfluthrin, cypermethrin, deltamethrin, and permethrin. In this study, the pyrethroid metabolites in workers' urine samples were monitored for the first time with a novel sample pretreatment process combining hollow fiber liquid phase microextraction (HF-LPME) and in-syringe derivatization (ISD) followed by gas chromatography-electron capture detector (GC-ECD) analysis. A micro-syringe pre-filled with derivatizing agents and syringe needle connected to an extracting solvent impregnated hollow fiber segment was used as the LPME probe. Pyrethroid metabolites were extracted and enriched simultaneously from urine samples by HF-LPME sampling and acid hydrolysis at 70 °C for 10 min. After sampling, the ISD was performed by mixing the extracting solution and derivatizing agents through plunger movements, followed by GC-ECD analysis. Parameters influencing the HF-LPME efficiency and ISD were investigated and optimized. Under optimum conditions, the method provided enrichment factors of 69.8-154.6, repeatability from 5.0 to 12% (n = 5), and good linearity (R(2) = 0.9980-0.9998) for interested analytes spiked in urine samples. The method detection limits ranged from 1.6 to 17 ng/mL. A comparison was performed between the proposed method and conventional methods. The proposed method was applied to analyze pyrethroid metabolites in the urine samples collected from workers of pesticide formulation plants. The results suggested that the proposed HF-LPME coupled ISD method was a rapid, simple, efficient, and eco-friendly technique in the biomonitoring of metabolites of pyrethroids in workers' urine.

  7. Determination of estrogenic compounds in milk and yogurt samples by hollow-fibre liquid-phase microextraction-gas chromatography-triple quadrupole mass spectrometry.

    Science.gov (United States)

    D'Orazio, Giovanni; Hernández-Borges, Javier; Herrera-Herrera, Antonio Vicente; Fanali, Salvatore; Rodríguez-Delgado, Miguel Ángel

    2016-10-01

    An environmentally friendly method based on hollow-fibre liquid-phase microextraction (HF-LPME) was developed for the extraction of selected estrogenic compounds (i.e. four natural sexual hormones: estrone, 17β-estradiol, 17α-estradiol and estriol; two exoestrogens: 17α-ethynylestradiol and 2-methoxyestradiol; two synthetic stilbenes: dienestrol and hexestrol; and five resorcylic acid lactones: zearalenone, α-zearalanol, β-zearalanol, α-zearalenol and β-zearalenol), from whole cow and semi-skimmed goat milk and whole natural yogurt. After the optimization of the sample preparation procedure, spiked extracts were derivatized to their trimethylsilyl products using N,O-bis(trimethylsilyl)trifluoroacetamide reagent and then analyzed by gas chromatography-tandem mass spectrometry (GC-MS/MS). Once optimum extraction conditions were established (protein precipitation with acetonitrile, extraction and the back-extraction in acetonitrile following the HF-LPME procedure), the method was validated and the calibration range, precision and accuracy were studied. The RSD values for the intra- and inter-day precision of the peak areas were in the range 0.65-9.69 and 1.00-11.47 %, respectively. The determination coefficients were higher than 0.991 for method calibration curves while LOD and LOQ values were between 0.06-2.55 and 0.16-6.11 μg/L for whole cow milk, 0.04-1.70 and 0.11-4.86 μg/L for semi-skimmed goat milk and 0.07-3.73 and 0.23-9.81 μg/L for natural yogurt, respectively. Finally, the accuracy and precision of the method were evaluated, obtaining a value in the range 84 81-119 % and RSD values lower than 20 % in all cases.

  8. Simultaneous quantification of amphetamines, caffeine and ketamine in urine by hollow fiber liquid phase microextraction combined with gas chromatography-flame ionization detector.

    Science.gov (United States)

    Xiong, Jun; Chen, Jie; He, Man; Hu, Bin

    2010-08-15

    A method of hollow fiber (HF) liquid phase microextraction (LPME) combined with gas chromatography (GC)-flame ionization detection (FID) was developed for the simultaneous quantification of trace amphetamine (AP), methamphetamine (MA), methylenedioxyamphetamine (MDA), methylenedioxymethamphetamine (MDMA), caffeine and ketamine (KT) in drug abuser urine samples. The factors affecting on the extraction of six target analytes by HF-LPME were investigated and optimized, and the subsequent analytical performance evaluation and real sample analysis were performed by the extraction of six target analytes in sample solution containing 30% NaCl (pH 12.5) for 20 min with extraction temperature of 30 degrees C and stirring rate of 1000 rpm. Under such optimal conditions, the limits of detection (LODs, S/N=3) for the six target analytes were ranged from 8 microg/L (AP, KT) to 82 microg/L (MDA), with the enrichment factors (EFs) of 5-227 folds, and the relative standard deviations (RSDs, n=7) were in the range of 6.9-14.1%. The correlation coefficients of the calibration for the six target analytes over the dynamic linear range were higher than 0.9958. The application feasibility of HF-LPME-GC-FID in illegal drug monitoring was demonstrated by analyzing drug abuser urine samples, and the recoveries of target drugs for the spiked sample ranging from 75.2% to 119.3% indicated an excellent anti-interference capability of the developed method. The proposed method is simple, effective, sensitive and low-cost, and provides a much more accurate and sensitive detection platform over the conventional analytical techniques (such as immunological assay) for drug abuse analysis. Copyright 2010 Elsevier B.V. All rights reserved.

  9. Hybrid field-assisted solid-liquid-solid dispersive extraction for the determination of organochlorine pesticides in tobacco with gas chromatography.

    Science.gov (United States)

    Zhou, Ting; Xiao, Xiaohua; Li, Gongke

    2012-01-03

    A novel one-step sample preparation technique termed hybrid field-assisted solid-liquid-solid dispersive extraction (HF-SLSDE) was developed in this study. A simple glass system equipped with a condenser was designed as an extraction vessel. The HF-SLSDE technique was a three-phase dispersive extraction approach. Target analytes were extracted from the sample into the extraction solvent enhanced by the hybrid field. Meanwhile, the interfering components were adsorbed by dispersing sorbent. No cleanup step preceded chromatographic analysis. The efficiency of the HF-SLSDE approach was demonstrated in the determination of organochlorine pesticide (OCP) residues in tobacco with a gas chromatography-electron capture detector (GC-ECD). Various operation conditions were studied systematically. Low detection limits (0.3-1.6 μg/kg) and low quantification limits (1.0-4.5 μg/kg) were achieved under the optimized conditions. The recoveries of OCPs ranged from 70.2% to 118.2%, with relative standard deviations of HF-SLSDE showed significant predominance compared with other extraction techniques. The dispersing sorbent with good cleanup ability used in this study was also found to be a microwave absorption medium, which could heat the nonpolar extraction solvent under microwave irradiation. Different microstructures of tobacco samples before and after extractions demonstrated the mechanism of HF-SLSDE was based on an explosion at the cell level. According to the results, HF-SLSDE was proved to be a simple and effective sample preparation method for the analysis of pesticide residues in solid samples and could potentially be extended to other nonpolar target analytes in a complex matrix. © 2011 American Chemical Society

  10. Hollow fibre-based liquid-phase microextraction technique combined with gas chromatography-mass spectrometry for the determination of pyrethroid insecticides in water samples.

    Science.gov (United States)

    San Román, I; Alonso, M L; Bartolomé, L; Alonso, R M

    2012-10-15

    A simple, easy-to-use, efficient and environmentally friendly method has been developed for the simultaneous analysis of nine pirethroid pesticides in water samples by the combination of hollow fibre-based liquid-phase microextraction (HF-LPME) and gas chromatography-mass spectrometry (GC/MS). For the developed method, nine pirethroid pesticides (esbiothrin, prallethrin, bifenthrin, tetramethrin, phenothrin, permethrin, cyfluthrin, cypermethrin and deltamethrin) were concentrated and well separated under optimal conditions. Several factors that influence the efficiency of HF-LPME were investigated and optimized by means of experimental design. The proposed method has good linearity in the concentration range of 10-400 μg L(-1) with correlation coefficients between 0.995 and 0.999. Overall enrichment factors for the optimized method ranged from 139 to 255 times except for cypermethrin and deltamethrin which ranged from 35 to 128. Detection and quantitation limits of the chromatographic method were in the range of 0.002-0.012 μg L(-1) and 0.003-0.026 μg L(-1) respectively, with RSD values between 4.2% and 18.4%. The recoveries varied in the range of 69.4%-122.7% except for cypermethrin and deltamethrin (17.5%-64.1%) with relative standard deviations between 1.0% and 24.0% for intra and inter-day experiments at different concentrations (0.1 μg L(-1), 0.5 μg L(-1), 1 μg L(-1)). The HF-LPME method optimized was applied to the analysis of three spiked real water samples with good results. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. Automated polyvinylidene difluoride hollow fiber liquid-phase microextraction of flunitrazepam in plasma and urine samples for gas chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Cui, Shufen; Tan, Shuo; Ouyang, Gangfeng; Pawliszyn, Janusz

    2009-03-20

    A new polyvinylidene difluoride (PVDF) hollow fiber (200 microm wall thickness, 1.2mm internal diameter, 0.2 microm pore size) was compared with two other polypropylene (PP) hollow fibers (200, 300 microm wall thickness, 1.2mm internal diameter, 0.2 microm pore size) in the automated hollow fiber liquid-phase microextraction (HF-LPME) of flunitrazepam (FLNZ) in biological samples. With higher porosity and better solvent compatibility, the PVDF hollow fiber showed advantages with faster extraction efficiency and operational accuracy. Parameters of the CTC autosampler program for HF-LPME in plasma and urine samples were carefully investigated to ensure accuracy and reproducibility. Several parameters influencing the efficiency of HF-LPME of FLNZ in plasma and urine samples were optimized, including type of porous hollow fiber, organic solvent, agitation rate, extraction time, salt concentration, organic modifier, and pH. Under optimal conditions, extraction recoveries of FLNZ in plasma and urine samples were 6.5% and 83.5%, respectively, corresponding to the enrichment factor of 13 in plasma matrix and 167 in urine matrix. Excellent sample clean-up was observed and good linearities (r(2)=0.9979 for plasma sample and 0.9995 for urine sample) were obtained in the range of 0.1-1000 ng/mL (plasma sample) and 0.01-1000 ng/mL (urine sample). The limits of detection (S/N=3) were 0.025 ng/mL in plasma matrix and 0.001 ng/mL in urine matrix by gas chromatography/mass spectrometry/mass spectrometry.

  12. Doping of three-dimensional porous carbon nanotube-graphene-ionic liquid composite into polyaniline for the headspace solid-phase microextraction and gas chromatography determination of alcohols

    Energy Technology Data Exchange (ETDEWEB)

    Li, Lulu; Wu, Mian; Feng, Yingying; Zhao, Faqiong; Zeng, Baizhao, E-mail: bzzeng@whu.edu.cn

    2016-12-15

    In this work, ionic liquid (IL, i.e. 1-hydroxyethyl-3-methylimidazolium tetrafluoroborate), carboxyl multiwall carbon nanotubes (MWCNTs) and reduced graphene oxide (rGO) were used to prepare three-dimensional porous material (MWCNTs-rGO-IL) by one-step self-assembly, then it was co-electrodeposited with polyaniline (PANI) on stainless steel wires by cyclic voltammetry. The resulting coating (PANI-MWCNTs-rGO-IL) was characterized by using FT-IR and scanning electron microscopy etc, and it showed porous structure and had high thermal stability. Furthermore, it was found to be very suitable for the headspace solid-phase microextraction of alcohols (i.e. octanol, nonanol, geraniol, decanol, undecanol and dodecanol). By coupling with gas chromatography, wide linear ranges and low limits of detection (i.e. 2.2–28.3 ng L{sup −1}) were obtained for the alcohols. The coating also presented good repeatability and reproducibility; the relative standard deviations for intra-fiber and fiber-to-fiber were less than 5.6% (n = 5) and 7.0% (n = 5) respectively. In addition, the proposed method was successfully applied to the determination of alcohols in tea drinks, and the recoveries for standards added were 85.6–114%. - Highlights: • A three-dimensional porous material (MWCNTs-rGO-IL) was synthesized by self-assembly. • A new PANI-MWCNTs-rGO-IL composite coating was prepared by electrochemical method. • It presented high thermal stability and extraction selectivity for alcohols.

  13. Doping of three-dimensional porous carbon nanotube-graphene-ionic liquid composite into polyaniline for the headspace solid-phase microextraction and gas chromatography determination of alcohols

    International Nuclear Information System (INIS)

    Li, Lulu; Wu, Mian; Feng, Yingying; Zhao, Faqiong; Zeng, Baizhao

    2016-01-01

    In this work, ionic liquid (IL, i.e. 1-hydroxyethyl-3-methylimidazolium tetrafluoroborate), carboxyl multiwall carbon nanotubes (MWCNTs) and reduced graphene oxide (rGO) were used to prepare three-dimensional porous material (MWCNTs-rGO-IL) by one-step self-assembly, then it was co-electrodeposited with polyaniline (PANI) on stainless steel wires by cyclic voltammetry. The resulting coating (PANI-MWCNTs-rGO-IL) was characterized by using FT-IR and scanning electron microscopy etc, and it showed porous structure and had high thermal stability. Furthermore, it was found to be very suitable for the headspace solid-phase microextraction of alcohols (i.e. octanol, nonanol, geraniol, decanol, undecanol and dodecanol). By coupling with gas chromatography, wide linear ranges and low limits of detection (i.e. 2.2–28.3 ng L −1 ) were obtained for the alcohols. The coating also presented good repeatability and reproducibility; the relative standard deviations for intra-fiber and fiber-to-fiber were less than 5.6% (n = 5) and 7.0% (n = 5) respectively. In addition, the proposed method was successfully applied to the determination of alcohols in tea drinks, and the recoveries for standards added were 85.6–114%. - Highlights: • A three-dimensional porous material (MWCNTs-rGO-IL) was synthesized by self-assembly. • A new PANI-MWCNTs-rGO-IL composite coating was prepared by electrochemical method. • It presented high thermal stability and extraction selectivity for alcohols.

  14. Liquid chromatography detection unit, system, and method

    Science.gov (United States)

    Derenzo, Stephen E.; Moses, William W.

    2015-10-27

    An embodiment of a liquid chromatography detection unit includes a fluid channel and a radiation detector. The radiation detector is operable to image a distribution of a radiolabeled compound as the distribution travels along the fluid channel. An embodiment of a liquid chromatography system includes an injector, a separation column, and a radiation detector. The injector is operable to inject a sample that includes a radiolabeled compound into a solvent stream. The position sensitive radiation detector is operable to image a distribution of the radiolabeled compound as the distribution travels along a fluid channel. An embodiment of a method of liquid chromatography includes injecting a sample that comprises radiolabeled compounds into a solvent. The radiolabeled compounds are then separated. A position sensitive radiation detector is employed to image distributions of the radiolabeled compounds as the radiolabeled compounds travel along a fluid channel.

  15. Hollow fiber supported liquid-phase microextraction using ionic liquid as extractant for preconcentration of benzene, toluene, ethylbenzene and xylenes from water sample with gas chromatography-hydrogen flame ionization detection.

    Science.gov (United States)

    Ma, Xiaoguo; Huang, Minghua; Li, Zhihua; Wu, Jianmei

    2011-10-30

    A novel method has been developed for the analysis of benzene, toluene, ethyl-benzene, and o-, m- and p-xylenes (BTEXs) in water using hollow fiber supported liquid-phase microextraction (HF-LPME) followed by gas chromatography-hydrogen flame ionization detection. Ionic liquid 1-butyl-3-methy-limidazolium hexafluorophosphate ([BMIM][PF(6)]) was acted as the extractant for extraction and preconcentration of BTEXs from aqueous samples, and a porous-walled polypropylene hollow fiber was utilized to stabilize and protect [BMIM][PF(6)] during the extraction process. Various parameters that affect extraction efficiency were investigated in detail, and the optimized experimental conditions were as follows: 8 μL of [BMIM][PF(6)] as extraction solvent for the target analytes in 20 mL of sample solution, 30 min of extraction time, a stirring rate of 1400 rpm and 15% NaCl (w/v) in aqueous sample at 25°C (ambient temperature). The recovery was found to be 90.0-111.5% with RSD (n=5) of 1.3-5.4%, and the detection limits (S/N=3) were in the range of 2.7-4.0 μg/L. The proposed method was simple, cheap, rapid, sensitive and environmentally benign, and could act as an alternative to techniques for BTEXs analysis with expensive instrumentations. Copyright © 2011 Elsevier B.V. All rights reserved.

  16. Accurate determination of 3-alkyl-2-methoxypyrazines in wines by gas chromatography quadrupole time-of-flight tandem mass spectrometry following solid-phase extraction and dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Fontana, Ariel; Rodríguez, Isaac; Cela, Rafael

    2017-09-15

    A new reliable method for the determination 3-alkyl-2-methoxypyrazines (MPs) in wine samples based on the sequential combination of solid-phase extraction (SPE), dispersive liquid-liquid microextraction (DLLME) and gas chromatography (GC) quadrupole time-of-flight accurate tandem mass spectrometry (QTOF-MS/MS) is presented. Primary extraction of target analytes was carried out by using a reversed-phase Oasis HLB (200mg) SPE cartridge combined with acetonitrile as elution solvent. Afterwards, the SPE extract was submitted to DLLME concentration using 0.06mL carbon tetrachloride (CCl 4 ) as extractant. Under final working conditions, sample concentration factors above 379 times and limits of quantification (LOQs) between 0.3 and 2.1ngL -1 were achieved. Moreover, the overall extraction efficiency of the method was unaffected by the particular characteristics of each wine; thus, accurate results (relative recoveries from 84 to 108% for samples spiked at concentrations from 5 to 25ngL -1 ) were obtained using matrix-matched standards, without using standard additions over every sample. Highly selective chromatographic records were achieved considering a mass window of 5mDa, centered in the quantification product ion corresponding to each compound. Twelve commercial wines, elaborated with grapes from different varieties and geographical origins, were processed with the optimized method. The 2-isobutyl-3-methoxypyrazine (IBMP) was determined at levels above the LOQs of the method in half of the samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Combination of accelerated solvent extraction and vortex-assisted liquid-liquid microextraction for the determination of dimethyl fumarate in textiles and leathers by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Lu, Yang; Zhu, Yan

    2014-02-01

    A simple and environmentally friendly sample preparation procedure coupled with gas chromatography-mass spectrometry was developed to assay dimethyl fumarate in textiles and leathers. The sample preparation procedure involved an accelerated solvent extraction (ASE) using water as the extract solvent, followed by the extraction and concentration of dimethyl fumarate from the aqueous solution using vortex-assisted liquid-liquid microextraction (VALLME). The parameters affecting the ASE and VALLME were optimized to achieve the maximum extraction efficiency, and the performance of the developed method was evaluated. Good linearity was observed over the range assayed (0.01-1mg/kg) with a regression coefficient of 0.998. The limit of detection and enrichment factor for the VALLME step were 0.001 mg/kg and 53, respectively. The intra- and inter-day precision were below 8.9%, and the recovery was approximately 84-103%. The as-developed method was successfully applied to textiles and leather samples. © 2013 Elsevier B.V. All rights reserved.

  18. Homogeneous liquid-liquid extraction (HoLLE) via flotation combined with gas chromatography-flame ionization detection as a very simple, rapid and sensitive method for the determination of fenitrothion in water samples.

    Science.gov (United States)

    Mashayekhi, Hossein Ali

    2013-01-01

    Homogeneous liquid-liquid extraction via flotation assistance (HoLLE-FA) and gas chromatography-flame ionization detection (GC-FID) was presented for the extraction and determination of fenitrothion in water samples. In this work, a rapid, simple and efficient HoLLE-FA method was developed based on applying low-density organic solvents without employing centrifugation. A special extraction cell was designed to facilitate the collection of low-density solvent extraction in the determination of fenitrothion in water samples. The water sample solution was added into an extraction cell that contained an appropriate mixture of extraction and homogeneous solvents. By using air flotation, the organic solvent was collected at the conical part of the designed cell. Under the optimum conditions, the method performance was studied in terms of the linear dynamic range (LDR from 1.0 up to 100 μg L⁻¹), linearity (r² > 0.998), and precision (repeatability extraction and determination of fenitrothion in three different water samples.

  19. Development of salt and pH-induced solidified floating organic droplets homogeneous liquid-liquid microextraction for extraction of ten pyrethroid insecticides in fresh fruits and fruit juices followed by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Torbati, Mohammadali; Farajzadeh, Mir Ali; Torbati, Mostafa; Nabil, Ali Akbar Alizadeh; Mohebbi, Ali; Afshar Mogaddam, Mohammad Reza

    2018-01-01

    A new microextraction method named salt and pH-induced homogeneous liquid-liquid microextraction has been developed in a home-made extraction device for the extraction and preconcentration of some pyrethroid insecticides from different fruit juice samples prior to gas chromatography-mass spectrometry. In the present work, an extraction device made from two parallel glass tubes with different lengths and diameters was used in the microextraction procedure. In this method, a homogeneous solution of a sample solution and an extraction solvent (pivalic acid) was broken by performing an acid-base reaction and the extraction solvent was produced in whole of the solution. The produced droplets of the extraction solvent went up through the solution and solidified using an ice-bath. They were collected without centrifugation step. Under the optimum conditions, limits of detection and quantification were obtained in the ranges of 0.006-0.038, and 0.023-0.134ngmL -1 , respectively. The enrichment factors and extraction recoveries of the selected analytes ranged from 365-460 to 73-92%, respectively. The relative standard deviations were lower than 9% for intra- (n = 6) and inter-day (n = 4) precisions at a concentration of 1ngmL -1 of each analyte. Finally, some fruit juice samples were effectively analyzed by the proposed method. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Gas chromatography-flame ionization determination of benzaldehyde in non-steroidal anti-inflammatory drug injectable formulations using new ultrasound-assisted dispersive liquid-liquid micro extraction

    International Nuclear Information System (INIS)

    Mashayekhi, H.A.; Pourshamsian, K.

    2012-01-01

    Summary: In this study, simple and efficient ultrasound-assisted dispersive liquid-liquid micro extraction combined with gas chromatography (GC) was developed for the preconcentration and determination of benzaldehyde in injectable formulations of the non-steroidal anti-inflammatory drugs, diclofenac, Vitamin B-complex and Voltaren injection solutions. Fourteen microliters of toluene was injected slowly into 10 mL home-designed centrifuge glass vial containing an aqueous sample without salt addition that was located inside the ultrasonic water bath. The formed emulsion was centrifuged and 2 macro L of separated toluene was injected into a gas chromatographic system equipped with a flame ionization detector (GC-FID) for analysis. Several factors influencing the extraction efficiency as the nature and volume of organic solvent, extraction temperature, ionic strength and centrifugation time were investigated and optimized. Using optimum extraction conditions a detection limit of 0.3 macro g L/sup -1/ and a good linearity in a calibration range of 2.0-1000 macro g L/sup -1/ were achieved for analyte. This proposed method was successfully applied to the analysis of benzaldehyde in three injection formulations and relative standard deviation (RSD) of analysis (n=3), before spiking with standard benzaldehyde were 3.3, 2.0 and 1.3% for Na-diclofenac, vitamin B-complex and voltaren, respectively and after spiking of standard benzaldehyde (0.3 mg L/sup -1/), the RSD were 6.5, 3.6 and 2.8% for Na-diclofenac, vitamin B-complex and voltaren, respectively. (author)

  1. Improved gas chromatography-negative ion chemical ionization tandem mass spectrometric method for determination of 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid in hair using mechanical pulverization and bead-assisted liquid-liquid extraction.

    Science.gov (United States)

    Kim, Jin Young; Cheong, Jae Chul; Lee, Jae Il; In, Moon Kyo

    2011-03-20

    A gas chromatography-negative ion chemical ionization tandem mass spectrometric (GC-NCI-MS/MS) method was developed and validated for the determination of 11-nor-Δ(9)-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) in human hair. After decontamination, hair samples were weighed (25mg), mechanically pulverized with a bead mill, and incubated in 0.7 mL of 1.0M sodium hydroxide at 95 °C for 30 min. Bead-assisted liquid-liquid extraction was performed with n-hexane:ethyl acetate (9:1, v/v), a method developed in our laboratory. The extract was evaporated to dryness, derivatized with pentafluoropropanol and pentafluoropropionic anhydride, and analyzed by GC-MS/MS in the negative ion chemical ionization mode using methane as the reagent gas. The linear ranges were 0.05-10.0 pg/mg for THC-COOH with the coefficient of determination (r(2) = 0.9976). The intra-day and inter-day precisions were within 1.7 and 13.8%, respectively. The intra-day and inter-day accuracies were -4.8 to 10.0% and -3.9 to 3.8%, respectively. The limit of detection and quantification were 0.015 and 0.05 pg/mg, respectively. The recoveries were in the range of 79.4-87.1%. The results indicate that the proposed method is simple, rapid, accurate, and precise for determination of THC-COOH in hair. The method identified THC-COOH in hair specimens from suspected marijuana abusers. Copyright © 2011. Published by Elsevier Ireland Ltd.

  2. Instrument platforms for nano liquid chromatography

    Czech Academy of Sciences Publication Activity Database

    Šesták, Jozef; Moravcová, Dana; Kahle, Vladislav

    2015-01-01

    Roč. 1421, NOV (2015), s. 2-17 ISSN 0021-9673 R&D Projects: GA MV VG20112015021 Institutional support: RVO:68081715 Keywords : nano liquid chromatography * splitless gradient generation * nano LC platforms Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.926, year: 2015 http://hdl.handle.net/11104/0250900

  3. Validated High Performance Liquid Chromatography Method for ...

    African Journals Online (AJOL)

    Purpose: To develop a simple, rapid and sensitive high performance liquid chromatography (HPLC) method for the determination of cefadroxil monohydrate in human plasma. Methods: Schimadzu HPLC with LC solution software was used with Waters Spherisorb, C18 (5 μm, 150mm × 4.5mm) column. The mobile phase ...

  4. Porphyrins profile by high performance liquid chromatography ...

    African Journals Online (AJOL)

    E. Fateen

    2008-09-07

    Sep 7, 2008 ... tation of urinary porphyrins by liquid chromatography tandem mass spectrometry (LC/MS/MS) and thereby the ... by HPLC/ESI/MS/MS used in this study is a modification for the method Stoev et al. while ion mapping technique is a ..... designed for application by the Biochemical Genetics Depart- ment team.

  5. Ultra Performance Liquid Chromatography Tandem Mass ...

    African Journals Online (AJOL)

    NICOLAAS

    drugs alone.16. After a single oral dose of 120–800 mg of NTB in healthy sub- jects in a fasting state the peak plasma NTB concentration (tmax) was found to be 4–7 h, with a half-life of approximately 9–17 h.17 ... performance liquid chromatography mass spectrometry/mass .... to the likely biological plasma constituents.

  6. Electrostatic interactions in gas-solid chromatography.

    Science.gov (United States)

    Benson, S. W.; King, J., Jr.

    1966-01-01

    Electrostatic theory of physical adsorption applied to gas-solid chromatography, discussing chromatographic inseparability of argon and oxygen at room temperature, prediction of elution order of many gases, etc

  7. Determination of valproic acid (DI-N-propyl acetic acid) in plasma by gas-liquid chromatography with pre-column butylation

    NARCIS (Netherlands)

    Hulshoff, A.; Roseboom, H.

    1979-01-01

    A gas-liquid chromatographic procedure for the determination of the anticonvulsant drug valproic acid in plasma or serum is described. Valproic acid is extracted from acidified plasma (or serum) into toluene containing octanoic acid as the internal standard. The toluene layer is back extracted with

  8. Characterization of the designer drug deschloroketamine (2-methylamino-2-phenylcyclohexanone) by gas chromatography/mass spectrometry, liquid chromatography/high-resolution mass spectrometry, multistage mass spectrometry, and nuclear magnetic resonance.

    Science.gov (United States)

    Frison, Giampietro; Zamengo, Luca; Zancanaro, Flavio; Tisato, Francesco; Traldi, Pietro

    2016-01-15

    Clinical and forensic toxicology laboratories are challenged every day by the analytical aspects of the new psychoactive substances phenomenon. In this study we describe the analytical characterization of a new ketamine derivative, deschloroketamine (2-methylamino-2-phenylcyclohexanone), contained in seized powders. The analytical techniques employed include gas chromatography/mass spectrometry (GC/MS), liquid chromatography/electrospray ionization coupled with Orbitrap high-resolution/MS (LC/ESI-HRMS), multistage MS (ESI-MS(n)), and NMR. The LC/ESI-HRMS analyses consisted of accurate mass measurements of MH(+) ions in full-scan mode; comparison of experimental and calculated MH(+) isotopic patterns; and examination of the isotopic fine structure (IFS) of the M + 1, M + 2, M + 3 isotopic peaks relative to the monoisotopic M + 0 peak. The collision-induced product ions of the MH(+) ions were studied by both HRMS and MS(n). (1)H and (13)C NMR measurements were carried out to confirm the chemical structure of the analyte. The EI mass spectra obtained by GC/MS analysis showed the presence of molecular ions at m/z 203, and main fragment ions at m/z 175, 174, 160, 147, 146, and 132. The application of LC/ESI-HRMS allowed us to obtain: the accurate mass of deschloroketamine MH(+) ions with a mass accuracy of 1.47 ppm; fully superimposable experimental and calculated MH(+) isotopic patterns, with a relative isotopic abundance value of 3.69 %; and the IFS of the M + 1, M + 2, M + 3 isotopic peaks completely in accordance with theoretical values. Examination of the product ions of MH(+), as well as the study of both (1)H and (13)C NMR spectra, enabled the full characterization of the molecular structure of deschloroketamine. The combination of the employed analytical techniques allowed the characterization of the seized psychoactive substance, in spite of the lack of a reference standard. Deschloroketamine is a ketamine analogue considered to be

  9. Single solid phase extraction method for the simultaneous analysis of polar and non-polar pesticides in urine samples by gas chromatography and ultra high pressure liquid chromatography coupled to tandem mass spectrometry.

    Science.gov (United States)

    Cazorla-Reyes, Rocío; Fernández-Moreno, José Luis; Romero-González, Roberto; Frenich, Antonia Garrido; Vidal, José Luis Martínez

    2011-07-15

    A new multiresidue method has been developed and validated for the simultaneous extraction of more than two hundred pesticides, including non-polar and polar pesticides (carbamates, organochlorine, organophosphorous, pyrethroids, herbicides and insecticides) in urine at trace levels by gas and ultra high pressure liquid chromatography coupled to ion trap and triple quadrupole mass spectrometry, respectively (GC-IT-MS/MS, UHPLC-QqQ-MS/MS). Non-polar and polar pesticides were simultaneously extracted from urine samples by a simple and fast solid phase extraction (SPE) procedure using C(18) cartridges as sorbent, and dichloromethane as elution solvent. Recovery was in the range of 60-120%. Precision values expressed as relative standard deviation (RSD) were lower than 25%. Identification and confirmation of the compounds were performed by the use of retention time windows, comparison of spectra (GC-amenable compounds) or the estimation of the ion ratio (LC-amenable compounds). For GC-amenable pesticides, limits of detection (LODs) ranged from 0.001 to 0.436 μg L(-1) and limits of quantification (LOQs) from 0.003 to 1.452 μg L(-1). For LC-amenable pesticides, LODs ranged from 0.003 to 1.048 μg L(-1) and LOQs ranged from 0.011 to 3.494 μg L(-1). Finally, the optimized method was applied to the analysis of fourteen real samples of infants from agricultural population. Some pesticides such as methoxyfenozide, tebufenozide, piperonyl butoxide and propoxur were found at concentrations ranged from 1.61 to 24.4 μg L(-1), whereas methiocarb sulfoxide was detected at trace levels in two samples. Copyright © 2011 Elsevier B.V. All rights reserved.

  10. Gas chromatography at the Tritium Laboratory Karlsruhe

    International Nuclear Information System (INIS)

    Laesser, R.; Gruenhagen, S.

    2003-08-01

    Among the analytical techniques (mass spectrometry, laser Raman spectroscopy, gas chromatography, use of ionisation chambers) employed at the Tritium Laboratory Karlsruhe (TLK), gas chromatography plays a prominent role. The main reasons for that are the simplicity of the gas chromatographic separation process, the small space required for the equipment, the low investment costs in comparison to other methods, the robustness of the equipment, the simple and straightforward analysis and the fact that all gas species of interest (with the exception of water) can easily be detected by gas chromatographic means. The conventional gas chromatographs GC1 and GC2 used in the Tritium Measurement Techniques (TMT) System of the TLK and the gas chromatograph GC3 of the experiment CAPER are presented in detail, by discussing their flow diagrams, their major components, the chromatograms measured by means of various detectors, shortcomings and possible improvements. One of the main disadvantages of the conventional gas chromatography is the long retention times required for the analysis of hydrogen gas mixtures. To overcome this disadvantage, micro gas chromatography for hydrogen analysis was developed. Reduction of the retention times by one order of magnitude was achieved. (orig.)

  11. Hollow fiber-based liquid phase microextraction with factorial design optimization and gas chromatography-tandem mass spectrometry for determination of cannabinoids in human hair.

    Science.gov (United States)

    Emídio, Elissandro Soares; de Menezes Prata, Vanessa; de Santana, Fernando José Malagueño; Dórea, Haroldo Silveira

    2010-08-15

    A new method, based on hollow fiber liquid-phase microextraction (HF-LPME) and gas chromatography-tandem mass spectrometry (GC-MSMS), was developed for determination of Delta(9)-tetrahydrocannabinol (THC), cannabidiol (CBD) and cannabinol (CBN) in samples of human hair. Since hair is a solid matrix, the samples were subjected to alkaline digestion using NaOH. The aqueous solutions obtained were extracted using a 6cm polypropylene fiber (600microm i.d., 200microm wall thickness, 0.2microm pore size) for each extraction. A 2(5-1) fractional factorial design for screening, and a central composite design for optimization of significant variables, was applied during development of the extraction method. The variables evaluated were the type of extraction solvent, pH, stirring speed, extraction time, and acceptor phase volume. The optimized conditions for the proposed extraction procedure were 10mg of hair sample; 20microL of butyl acetate; aqueous (pH 14) donor phase containing 6.8% NaCl; 600rpm stirring speed; 20min extraction time. A linear response was obtained in the ranges 1-500pgmg(-1) (CBD and CBN) and 20-500pgmg(-1) (THC), with regression coefficients >0.99. Precision, determined as the relative standard deviation, was 3.3-8.9% (intra-day) and 4.4-13.7% (inter-day). Absolute recoveries varied in the ranges 4.4-4.8% (CBD), 7.6-8.9% (THC) and 7.7-8.2% (CBN). Limits of detection (LOD, S/N=3) and quantification (LOQ, S/N=10) were 0.5-15pgmg(-1) and 1-20pgmg(-1), respectively. The method was successfully used to determine CBD, THC and CBN in hair samples from patients in a drug dependency rehabilitation center. Concentrations varied in the ranges 1-18pgmg(-1) (CBD), 20-232pgmg(-1) (THC) and 9-107pgmg(-1) (CBN), confirming the suitability of the method for monitoring studies. Copyright 2010 Elsevier B.V. All rights reserved.

  12. Recent development of ionic liquid stationary phases for liquid chromatography.

    Science.gov (United States)

    Shi, Xianzhe; Qiao, Lizhen; Xu, Guowang

    2015-11-13

    Based on their particular physicochemical characteristics, ionic liquids have been widely applied in many fields of analytical chemistry. Many types of ionic liquids were immobilized on a support like silica or monolith as stationary phases for liquid chromatography. Moreover, different approaches were developed to bond covalently ionic liquids onto the supporting materials. The obtained ionic liquid stationary phases show multi-mode mechanism including hydrophobic, hydrophilic, hydrogen bond, anion exchange, π-π, and dipole-dipole interactions. Therefore, they could be used in different chromatographic modes including ion-exchange, RPLC, NPLC and HILIC to separate various classes of compounds. This review mainly summarizes the immobilized patterns and types of ionic liquid stationary phases, their retention mechanisms and applications in the recent five years. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Use of a capillary tube for collecting an extraction solvent lighter than water after dispersive liquid-liquid microextraction and its application in the determination of parabens in different samples by gas chromatography--flame ionization detection.

    Science.gov (United States)

    Farajzadeh, M A; Djozan, Dj; Bakhtiyari, R Fazeli

    2010-06-15

    In this study a new dispersive liquid-liquid microextraction (DLLME) method is presented on the basis of a safe organic solvent, octanol, which is lighter than water. The proposed method is used for the extraction and pre-concentration of some preservatives including methyl paraben (Mep), ethyl paraben (Etp) and propyl paraben (Prp) from different matrices. The extracted compounds are monitored by gas chromatography-flame ionization detector (GC-FID). A mixture of suitable extraction and dispersive solvents including 20microL octanol and 0.5mL acetone is quickly injected into the aqueous sample. The mixture is centrifuged for 10min at 6000rpm, so a small drop of extraction solvent collects on the water surface. A portion of the collected solvent is removed by a capillary tube through simple dipping the tube into organic solvent drop. 0.4microL of extract into the tube is removed by a microsyringe and injected into GC. Some effective parameters such as kinds and volumes of extraction and dispersive solvents as well as extraction time have to be investigated. Under optimum conditions, enrichment factors and recoveries of the studied compounds were obtained in the range of 100-276 and 25-72%, respectively. Linear ranges of the calibration curves were between 0.05 and 30 for methyl- and 0.02 and 30microgmL(-1) for ethyl- and propyl parabens, respectively. Limit of detection for methyl paraben was 0.015microgmL(-1) and those of ethyl- and propyl parabens were 0.005microgmL(-1). Relative standard deviations (RSDs %) for six repeated measurements (C=2microgmL(-1)) were 2% for methyl-, and ethyl parabens and 3% for propyl parabens, respectively.

  14. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory : determination of organophosphate pesticides in whole water by continuous liquid-liquid extraction and capillary-column gas chromatography with flame photometric detection

    Science.gov (United States)

    Jha, Virendra K.; Wydoski, Duane S.

    2003-01-01

    A method for the isolation of 20 parent organophosphate pesticides and 5 organophosphate pesticide degradates from natural-water samples is described. Compounds are extracted from water samples with methylene chloride using a continuous liquid-liquid extractor for 6 hours. The solvent is evaporated using heat and a flow of nitrogen to a volume of 1 milliliter and solvent exchanged to ethyl acetate. Extracted compounds are determined by capillary-column gas chromatography with flame photometric detection. Single-operator derived method detection limits in three water-matrix samples ranged from 0.003 to 0.009 microgram per liter. Method performance was validated by spiking all compounds in three different matrices at three different concentrations. Eight replicates were analyzed at each concentration in each matrix. Mean recoveries of most method compounds spiked in surface-water samples ranged from 54 to 137 percent and those in ground-water samples ranged from 40 to 109 percent for all pesticides. Recoveries in reagent-water samples ranged from 42 to 104 percent for all pesticides. The only exception was O-ethyl-O-methyl-S-propylphosphorothioate, which had variable recovery in all three matrices ranging from 27 to 79 percent. As a result, the detected concentration of O-ethyl-O-methyl-S-propylphosphorothioate in samples is reported in this method with an estimated remark code. Based on the performance issue, two more compounds, disulfoton and ethion monoxon, also will be reported in this method with an estimated remark code. Estimated-value compounds, which are ?E-coded? in the data base, do not meet the performance criteria for unqualified quantification, but are retained in the method because the compounds are important owing to high use or potential environmental effects and because analytical performance has been consistent and reproducible.

  15. Ultrasound-assisted low-density solvent dispersive liquid-liquid microextraction for the determination of 4 designer benzodiazepines in urine samples by gas chromatography-triple quadrupole mass spectrometry.

    Science.gov (United States)

    Meng, Liang; Zhu, Binling; Zheng, Kefang; Fu, Shanlin

    2017-05-15

    A novel microextraction technique based on ultrasound-assisted low-density solvent dispersive liquid-liquid microextraction (UA-LDS-DLLME) had been applied for the determination of 4 designer benzodiazepines (phenazepam, diclazepam, flubromazepam and etizolam) in urine samples by gas chromatography- triple quadrupole mass spectrometry (GC-QQQ-MS). Ethyl acetate (168μL) was added into the urine samples after adjusting pH to 11.3. The samples were sonicated in an ultrasonic bath for 5.5min to form a cloudy suspension. After centrifugation at 10000rpm for 3min, the supernatant extractant was withdrawn and injected into the GC-QQQ-MS for analysis. Parameters affecting the extraction efficiency have been investigated and optimized by means of single factor experiment and response surface methodology (Box-Behnken design). Under the optimum extraction conditions, a recovery of 73.8-85.5% were obtained for all analytes. The analytical method was linear for all analytes in the range from 0.003 to 10μg/mL with the correlation coefficient ranging from 0.9978 to 0.9990. The LODs were estimated to be 1-3ng/mL. The accuracy (expressed as mean relative error MRE) was within ±5.8% and the precision (expressed as relative standard error RSD) was less than 5.9%. UA-LDS-DLLME technique has the advantages of shorter extraction time and is suitable for simultaneous pretreatment of samples in batches. The combination of UA-LDS-DLLME with GC-QQQ-MS offers an alternative analytical approach for the sensitive detection of these designer benzodiazepines in urine matrix for clinical and medico-legal purposes. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. UHPLC: The Greening Face of Liquid Chromatography.

    Science.gov (United States)

    Cielecka-Piontek, Judyta; Zalewski, Przemysław; Jelińska, Anna; Garbacki, Piotr

    2013-01-01

    Pharmaceutical analysis based on chromatographic separation is an important part of studies aimed at developing routine quality analysis of drugs. High-performance liquid chromatography (HPLC) is one of the main analytical techniques recommended for drug analysis. Although it meets many criteria vital for analysis, it is time-consuming and uses a relatively high amount of organic solvents compared to other analytical techniques. Recently, Ultra-high-performance liquid chromatography (UHPLC) has been frequently proposed as an alternative to HPLC, which means introducing an environment-friendly approach to drug analysis achieved by reducing the consumption of solvents. It also offers greater chromatographic resolution and higher sensitivity as well as requiring less time due to faster analysis. This review focuses on the basics of UHPLC, compares that technique with HPLC and discusses the possibilities of applying UHPLC for the analysis of different pharmaceuticals and biopharmaceuticals.

  17. Application of gas chromatography in hydrogen isotope separation

    International Nuclear Information System (INIS)

    Ye Xiaoqiu; Sang Ge; Peng Lixia; Xue Yan; Cao Wei

    2008-01-01

    The principle of gas chromatographic separation of hydrogen isotopes was briefly introduced. The main technology and their development of separating hydrogen isotopes, including elution chromatography, hydrogen-displacement chromatography, self-displacement chromatography and frontal chromatography were discussed in detail. The prospect of hydrogen isotope separation by gas chromatography was presented. (authors)

  18. Capillary gas chromatography in essential oil analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sandra, P.; Bicchi, C. (eds.)

    1987-01-01

    Capillary GC has strongly contributed to the development of essential oil science both from an industrial point of view (quality control, new sources of odoriferous compounds) and from a scientific point of view (phytochemistry, chemotaxonomy, biochemistry, etc). The reserve, however, is also true. Essential oil research has contributed to the present state of the art in capillary gas chromatography, e.g. the polar and sometimes thermolabile character of essential oil components has emphasized the need for more inert capillary columns and better sample introduction systems, selective polar phases have been developed, etc. Within 14 separate contributions of the book the following topics are discussed: general aspects of essential oil preparation and analysis, considerations on the selection of capillary columns for the analysis, microtechniques, headspace versus classical analysis, 'fingerprints', industrial quality control, retention indices, dual channel analysis, gas chromatography-mass spectroscopy coupling, examples of artefact formation, GC-FTIR analysis, multidimensional gas chromatography.

  19. Temperature programmable microfabricated gas chromatography column

    Science.gov (United States)

    Manginell, Ronald P.; Frye-Mason, Gregory C.

    2003-12-23

    A temperature programmable microfabricated gas chromatography column enables more efficient chemical separation of chemical analytes in a gas mixture by the integration of a resistive heating element and temperature sensing on the microfabricated column. Additionally, means are provided to thermally isolate the heated column from their surroundings. The small heat capacity and thermal isolation of the microfabricated column improves the thermal time response and power consumption, both important factors for portable microanalytical systems.

  20. Some recent developments in headspace gas chromatography

    Science.gov (United States)

    J.Y. Zhu; X.-S. Chai

    2005-01-01

    In this study, recent developments in headspace gas chromatography (HSGC) are briefly reviewed. Several novel HSGC techniques developed recently are presented in detail. These techniques were developed using the unique characteristics of the headspace sampling process implemented in commercial HSGC systems and therefore can be easily applied in laboratory and...

  1. Low-density solvent-based vortex-assisted surfactant-enhanced-emulsification liquid-liquid microextraction combined with gas chromatography-mass spectrometry for the fast determination of phthalate esters in bottled water.

    Science.gov (United States)

    Zhang, Yufeng; Lee, Hian Kee

    2013-01-25

    For the first time, a novel low-density solvent-based vortex-assisted surfactant-enhanced-emulsification liquid-liquid microextraction (LDS-VSLLME) was developed for the fast, simple and efficient determination of six phthalate esters (PEs) in bottled water samples followed by gas chromatography-mass spectrometry (GC-MS). In the extraction procedure, the aqueous sample solution was injected into a mixture of extraction solvent (toluene) and surfactant (cetyltrimethyl ammonium bromide), which were placed in a glass tube with conical bottom, to form an emulsion by the assistance of vortex agitation. After extraction and phase separation by centrifugation, and removal of the spent sample, the toluene extract was collected and analyzed by GC-MS. The addition of surfactant enhanced the dispersion of extraction solvent in aqueous sample and was also favorable for the mass transfer of the analytes from the aqueous sample to the extraction solvent. Moreover, using a relatively less toxic surfactant as the emulsifier agent overcame the disadvantages of traditional organic dispersive solvents that are usually highly toxic and expensive and might conceivably decrease extraction efficiency to some extent since they are not as effective as surfactants themselves in generating an emulsion. With the aid of surfactant and vortex agitation to achieve good organic extraction solvent dispersion, extraction equilibrium was achieved within 1 min, indicating it was a fast sample preparation technique. Another prominent feature of the method was the simple procedure to collect a less dense than water solvent by a microsyringe. After extraction and phase separation, the aqueous sample was removed using a 5-mL syringe, thus leaving behind the extract, which was retrieved easily. This novel method simplifies the use of low-density solvents in DLLME. Under the optimized conditions, the proposed method provided good linearity in the range of 0.05-25 μg/L, low limits of detection (8-25 ng

  2. Non-polar lipids characterization of Quinoa (Chenopodium quinoa) seed by comprehensive two-dimensional gas chromatography with flame ionization/mass spectrometry detection and non-aqueous reversed-phase liquid chromatography with atmospheric pressure chemical ionization mass spectrometry detection.

    Science.gov (United States)

    Fanali, Chiara; Beccaria, Marco; Salivo, Simona; Tranchida, Peter; Tripodo, Giusy; Farnetti, Sara; Dugo, Laura; Dugo, Paola; Mondello, Luigi

    2015-07-08

    A chemical characterization of major lipid components, namely, triacylglycerols, fatty acids and the unsaponifiable fraction, in a Quinoa seed lipids sample is reported. To tackle such a task, non-aqueous reversed-phase high-performance liquid chromatography with mass spectrometry detection was employed. The latter was interfaced with atmospheric pressure chemical ionization for the analysis of triacylglycerols. The main triacylglycerols (>10%) were represented by OLP, OOL and OLL (P = palmitoyl, O = oleoyl, L = linoleoyl); the latter was present in the oil sample at the highest percentage (18.1%). Furthermore, fatty acid methyl esters were evaluated by gas chromatography with flame ionization detection. 89% of the total fatty acids was represented by unsaturated fatty acid methyl esters with the greatest percentage represented by linoleic and oleic acids accounting for approximately 48 and 28%, respectively. An extensive characterization of the unsaponifiable fraction of Quinoa seed lipids was performed for the first time, by using comprehensive two-dimensional gas chromatography with dual mass spectrometry/flame ionization detection. Overall, 66 compounds of the unsaponifiable fraction were tentatively identified, many constituents of which (particularly sterols) were confirmed by using gas chromatography with high-resolution time-of-flight mass spectrometry. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Optimizing separations in online comprehensive two-dimensional liquid chromatography.

    Science.gov (United States)

    Pirok, Bob W J; Gargano, Andrea F G; Schoenmakers, Peter J

    2018-01-01

    Online comprehensive two-dimensional liquid chromatography has become an attractive option for the analysis of complex nonvolatile samples found in various fields (e.g. environmental studies, food, life, and polymer sciences). Two-dimensional liquid chromatography complements the highly popular hyphenated systems that combine liquid chromatography with mass spectrometry. Two-dimensional liquid chromatography is also applied to the analysis of samples that are not compatible with mass spectrometry (e.g. high-molecular-weight polymers), providing important information on the distribution of the sample components along chemical dimensions (molecular weight, charge, lipophilicity, stereochemistry, etc.). Also, in comparison with conventional one-dimensional liquid chromatography, two-dimensional liquid chromatography provides a greater separation power (peak capacity). Because of the additional selectivity and higher peak capacity, the combination of two-dimensional liquid chromatography with mass spectrometry allows for simpler mixtures of compounds to be introduced in the ion source at any given time, improving quantitative analysis by reducing matrix effects. In this review, we summarize the rationale and principles of two-dimensional liquid chromatography experiments, describe advantages and disadvantages of combining different selectivities and discuss strategies to improve the quality of two-dimensional liquid chromatography separations. © 2017 The Authors. Journal of Separation Science published by WILEY-VCH Verlag GmbH & Co. KGaA.

  4. Ionization-based detectors for gas chromatography.

    Science.gov (United States)

    Poole, Colin F

    2015-11-20

    The gas phase ionization detectors are the most widely used detectors for gas chromatography. The column and makeup gases commonly used in gas chromatography are near perfect insulators. This facilitates the detection of a minute number of charge carriers facilitating the use of ionization mechanisms of low efficiency while providing high sensitivity. The main ionization mechanism discussed in this report are combustion in a hydrogen diffusion flame (flame ionization detector), surface ionization in a plasma (thermionic ionization detector), photon ionization (photoionization detector and pulsed discharge helium ionization detector), attachment of thermal electrons (electron-capture detector), and ionization by collision with metastable helium species (helium ionization detector). The design, response characteristics, response mechanism, and suitability for fast gas chromatography are the main features summarized in this report. Mass spectrometric detection and atomic emission detection, which could be considered as ionization detectors of a more sophisticated and complex design, are not discussed in this report. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. High-throughput determination of nicotine in plasma by ultrasonication enhanced hollow fiber liquid-phase microextraction prior to gas chromatography.

    Science.gov (United States)

    Liu, Xiaotian; Liang, Shumei; Pan, Jie; Guo, Yugao; Luo, Huiru; Zhao, Qingsong; Guan, Shan

    2014-07-01

    In high-throughput ultrasonication enhanced hollow-fiber liquid-phase microextraction (H-U-HF-LPME), ultrasonication was introduced into HF-LPME to enhance the mass transfer rate of the analytes in the two immiscible liquid phases, which resulted in a very short time for extraction equilibrium and a high-throughput analysis. Several parameters were investigated and optimized (such as extraction solvent, temperature of sample, frequency and intensity of ultrasonication, volume of extractant, extraction time, ionic strength of the sample and sample concentration). Based on the results of this study, nicotine was first extracted from a 1.5 mL sample solution under the optimum conditions (ultrasonic power of 50 W with a frequency of 60 kHz, extraction time of 10 min, sodium chloride concentration of 5 mol/L and temperature of 37°C). Next, 0.5 µL of acceptor solution inside the hollow fiber was automatically injected into a gas chromatograph with a flame ionization detector. The results of this study illustrated that the limit of detection, relative standard deviation (n = 6), relative recovery and enrichment factor of nicotine were 0.06 µg/L, 3%, 99.8% and 16.6, respectively. Finally, H-U-HF-LPME was successfully applied for the determination of nicotine in plasma. © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. Hollow fiber based liquid phase microextraction for the determination of organochlorine pesticides in ecological textiles by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Cai, Jin'an; Chen, Guosheng; Qiu, Junlang; Jiang, Ruifen; Zeng, Feng; Zhu, Fang; Ouyang, Gangfeng

    2016-01-01

    In this study, the hollow fiber-liquid phase microextraction (HF-LPME) coupled gas chromatograph/mass spectrometry (GC/MS) was firstly developed to determine 10 organochlorine pesticides (OCPs) in ecological textiles. The present method can offer high separation efficiencies with minimal sample and solvent consumption. The extraction conditions were optimized, including the types of hollow fiber and organic solvent, the extraction time, the stirring and the salinity. Under the optimized conditions, the linear ranges of OCPs in cotton, terylene and fur samples were 5-1000 ng/g, 10-1000 ng/g and 10-800 ng/g, respectively, and the detection limit of the three samples were 0.07-2.30 ng/g, 0.89-1.66 ng/g and 0.06-1.04 ng/g, respectively. The optimized method was then successfully used to determine the OCPs in 3 kinds of spiked real samples, including cotton, terylene and fur. The good recoveries and RSDs of the quantification in real textile samples were obtained and the results were confirmed by the traditional liquid extraction method (GB/T 18412-2006). This study proved that the HF-LPME method, which was simple, low-cost and virtually solvent-free, was reliable for the qualitative and quantitative analysis of the harmful OCP residues in ecological textiles. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Determination of 3-chloropropane-1,2-diol in liquid hydrolyzed vegetable proteins and soy sauce by solid-phase microextraction and gas chromatography/mass spectrometry.

    Science.gov (United States)

    Huang, Minjia; Jiang, Guibin; He, Bin; Liu, Jingfu; Zhou, Qingxiang; Fu, Wusheng; Wu, Yongning

    2005-11-01

    Headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography/mass spectrometry (GC/MS) method was developed to determine 3-chloropropane-1,2-diol (3-MCPD) in hydrolyzed vegetable protein and Chinese soy sauce. The 3-MCPD was firstly derivativized with phenylboronic acid in aqueous solution at 90 degrees C for 10 min, then extracted by HS-SPME and finally detected with GC/MS, parameters related to both the derivative reaction and the HS-SPME process were optimized. The proposed method has a linear range of 0.0194-394 microg g(-1), a detection limit of 3.87 ng g(-1) (S/N = 3), and a precision of RSD = 7.5% (n = 5). Seventeen real samples, including four HVPs and thirteen soy sauce samples, were analyzed to examine the feasibility of the proposed procedure; with a concentration of 3-MCPD and acceptable recoveries at 0.71 microg g(-1) spiked levels were obtained. Being simpler, faster and more environmentally benign than the existing methods, this method is accurate and suitable for routine analysis.

  8. Polybrominated diphenyl ethers (PBDEs) contents in house and car dust of Portugal by pressurized liquid extraction (PLE) and gas chromatography-mass spectrometry (GC-MS).

    Science.gov (United States)

    Cunha, S C; Kalachova, K; Pulkrabova, J; Fernandes, J O; Oliveira, M B P P; Alves, A; Hajslova, J

    2010-03-01

    Dust is the repository of various compounds including flame retardants. In this study an analytical method based on PLE extraction and gas chromatography-mass spectrometry was selected for the analysis of 16 PBDEs congeners in house and car dust samples collected in Portugal. The analytical performance of the method was validated using standard reference material (SRM); values from 90% to 109% and from 2% to 11% were obtained for recovery and precision, respectively. The PBDE congeners distribution in whole and sieved fractions of the dust samples, as well as influence of the source on the levels of these contaminants, were obtained. The wide range of PBDEs contents found in the dust samples indicates heterogeneous levels of contamination in these matrices. The clearest feature of the results obtained was that Deca-BDE was the main PBDE in both house and car dust samples. The total PBDEs measured in house dust (ranging from 34 to 1928 ng g(-1)) was lower than those found in car dust (ranging from 193 to 22955 ng g(-1)). However, house dust provides a major contribution to human exposure due to the time spent there, much higher than in cars. Copyright (c) 2009 Elsevier Ltd. All rights reserved.

  9. Improved Thermal Modulator for Gas Chromatography

    Science.gov (United States)

    Hasselbrink, Ernest Frederick, Jr.; Hunt, Patrick J.; Sacks, Richard D.

    2008-01-01

    An improved thermal modulator has been invented for use in a variant of gas chromatography (GC). The variant in question denoted as two-dimensional gas chromatography (2DGC) or GC-GC involves the use of three series-connected chromatographic columns, in the form of capillary tubes coated interiorly with suitable stationary phases (compounds for which different analytes exhibit different degrees of affinity). The two end columns are relatively long and are used as standard GC columns. The thermal modulator includes the middle column, which is relatively short and is not used as a standard GC column: instead, its temperature is modulated to affect timed adsorption and desorption of analyte gases between the two end columns in accordance with a 2DGC protocol.

  10. Natural Gas Liquid Pipelines

    Data.gov (United States)

    Department of Homeland Security — Natural gas interstate and intrastate pipelines in the United States. Based on a variety of sources with varying scales and levels of accuracy and therefore accuracy...

  11. A liquid-phase microextraction method, combining a dual gauge microsyringe with a hollow fiber membrane, for the determination of organochlorine pesticides in aqueous solution by gas chromatography/ion trap mass spectrometry.

    Science.gov (United States)

    Yan, Chih-Hao; Wu, Hui-Fen

    2004-01-01

    A liquid-phase microextraction (LPME) method has been demonstrated for the extraction and determination of organochlorine pesticides (OCPs) in aqueous solution. The method combines a dual gauge microsyringe with a hollow fiber membrane (LPME/DGM-HF) followed by detection by gas chromatography/ion trap mass spectrometry (GC/ITMS). The advantages include speed, low solvent and sample consumption, simplicity and ease of use. The extraction time, solvent selection, salt concentration and sample stirring rate have been investigated in order to optimize extraction efficiency. The viability is evaluated by measuring the linearity and detection limit of the five OCPs in aqueous solution. Detection linearity for the OCPs has been achieved over a range of concentrations between 1 and 500 microg/L (r2 > 0.930), with a detection limit of 0.1 microg/L for each OCP. Copyright 2004 John Wiley & Sons, Ltd.

  12. Comprehensive two-dimensional liquid chromatography: Ion chromatography × reversed-phase liquid chromatography for separation of low-molar-mass organic acids

    NARCIS (Netherlands)

    Brudin, S.S.; Shellie, R.A.; Haddad, P.R.; Schoenmakers, P.J.

    2010-01-01

    In the work presented here a novel approach to comprehensive two-dimensional liquid chromatography is evaluated. Ion chromatography is chosen for the first-dimension separation and reversed-phase liquid chromatography is chosen for the second-dimension separation mode. The coupling of these modes is

  13. Optimizing separations in online comprehensive two-dimensional liquid chromatography

    NARCIS (Netherlands)

    Pirok, Bob W.J.; Gargano, Andrea F.G.; Schoenmakers, Peter J.

    2018-01-01

    Online comprehensive two-dimensional liquid chromatography has become an attractive option for the analysis of complex nonvolatile samples found in various fields (e.g. environmental studies, food, life, and polymer sciences). Two-dimensional liquid chromatography complements the highly popular

  14. Liquid Crystals as Stationary Phases in Chromatography.

    Science.gov (United States)

    Grajek, H; Witkiewicz, Z; Purchała, M; Drzewiński, W

    2016-01-01

    The most correct analysis of the compositions of diverse analytes mixtures is significant for analytical studies in different fields; however, many prevalent analytes cannot be identified employing traditional partition gas chromatographic methods. Thus, the increasing requirements on analytes of isomeric compounds and the problems encountered in their separation demand a study of more diverse analytical systems which are characterised by higher selectivity. Therefore, the selectivity and polarities of various liquid crystals (rod-like, banana-shape, biforked, oxygen, sulphur, nitrogen, and metal containing molecules, Schiff-base, and polymeric dendrimers) employed as liquid crystalline stationary phases (LCSPs) have been discussed from both points of views, namely, their analytical applications and thermodynamic characteristics of infinitely diluted probes with different acceptor-donor properties. Extreme particular effort has been paid to the different interdependencies between the bound up chemical structures of liquid crystal molecules with their different acceptor-donor properties and the connected resolution capabilities in the interpretation of the probe-LCSP systems, on the basis of the [Formula: see text] and [Formula: see text] dependencies, with regard to the LCSP compositions, which have been controlled by the counterbalancing of the enthalpy and entropy factors. The properties of binary systems composed of liquid crystalline poly(propyleneimine) dendrimers-rod-like molecules of liquid crystals and effects of the dendrimer structure, the chemical nature, and molecular size of the non-mesogens on the ability to dissolve in the liquid crystalline phases, have been interpreted. Practical applications of metallomesogenes and chiral stationary phases for analytical separation of different organic substances have also been taken into consideration.

  15. Solute-solvent interaction parameters by gas chromatography.

    Science.gov (United States)

    Kováts, Ervin sz; Fóti, György; Dallos, András

    2004-08-13

    Gas-liquid distribution coefficients at ideal dilution in non-volatile solvents can be measured by gas chromatography. The numerical value of a coefficient depends on the choice of the concentration unit in the solvent and in the gas phase. The relationships between different coefficients characterizing gas-liquid equilibria are discussed and summarized. Coefficients determined at several temperatures permit calculation of the standard chemical potential difference of the solute with the ideal gas phase as reference as a function of temperature, the g-SPOT. Following the proposal of Kirchhoff the latter can be formulated as an equation with three constants. As in the gas phase the molecules of the solute have no interacting partners, the three constants, deltaH, deltaS and deltaC, characterize the interaction between solvent and solute molecules. They will be called the "solute-solvent interaction parameters". In the same system the values of these parameters depend on the choice of the distribution coefficient. Five different distribution coefficients result five sets of interaction parameters. It is shown that conversion of a parameter set to another implies additive corrections independent of the nature of the solute. If g-SPOT-s are measured in a series of solvents, the data may be used to calculate the corresponding liquid-liquid partition coefficients by electing one of the solvents as reference (l-SPOT). The corresponding "relative interaction parameters" can be calculated by simple substraction. In a second chapter the precautions are summarized, necessary for gas chromatographic determination of distribution coefficients and examples are given for interaction parameters in different systems. It is concluded that there are significant differences between g-SPOT-s related to different distribution coefficients. On the other hand, differences between l-SPOT-s are negligible.

  16. Enhanced methods for conditioning, storage, and extraction of liquid and solid samples of manure for determination of steroid hormones by solid-phase extraction and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Combalbert, Sarah; Pype, Marie-Laure; Bernet, Nicolas; Hernandez-Raquet, Guillermina

    2010-09-01

    Hormones are among the highest-impact endocrine disrupters affecting living organisms in aquatic environments. These molecules have been measured in both wastewater and sewage sludge. Analytical techniques for such matrices are well described in the literature. In contrast, there is little information about the analysis of hormones in animal waste. The objectives of this study were, first, to propose a method for conditioning swine manure samples (addition of formaldehyde, separation of the solid and liquid phases, and duration of storage) in order to determine hormones in the liquid fraction of manure by solid-phase extraction (SPE) coupled with gas chromatography-mass spectrometry (GC-MS). Our results showed that analysis of hormones was affected by matrix changes which occurred during freezing and thawing and after addition of formaldehyde, an additive frequently used to preserve environmental samples. Thus, our results argue for the conditioning of samples without formaldehyde and for separating the solid and liquid fractions of manure before freezing. Second, this study reports on the use of a liquid extraction method coupled with SPE and GC-MS analysis for determination of hormones in the solid fraction of manure. Under the conditions selected, hormone recoveries were between 80 and 100%. Finally, the optimized method was used to quantify hormones in both liquid and solid fractions of swine manure from different breeding units. High levels of estrone and α-estradiol were found in samples whereas β-estradiol was detected in smaller amounts. Estriol and progesterone were mainly found in manure from the gestating sow building whereas testosterone was detected in manure from male breeding buildings.

  17. Simultaneous derivatization and extraction of amphetamine and methylenedioxyamphetamine in urine with headspace liquid-phase microextraction followed by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Chiang, Jing-Shan; Huang, Shang-Da

    2008-03-21

    A new method is reported for the simultaneous extraction and derivatization of amphetamine (AM) and methylenedioxyamphetamine (MDA) using headspace hollow fiber protected liquid-phase microextraction (HS-HF-LPME); quantitation is by gas chromatograph-mass spectrometry in the selected ion monitoring (SIM) mode. The derivatizing reagent, pentafluorobenzaldehyde (PFBAY), was added to the extraction solvent. The analytes, volatile and basic, were released from the sample matrix into the headspace first, then extracted and derivatized in the solvent. After that, 2 microl of extract was directly injected into the GC-MS system. Parameters affecting extraction efficiency were investigated and optimized. This method showed good linearity in the concentration range investigated (50-350 ng ml(-1) for AM and 50-700 ng ml(-1) for MDA). Excellent repeatability of the extraction (RSD< or = 4%, n=5), and low limits of quantitation (0.25 ng ml(-1) for AM and 1.00 ng ml(-1) for MDA) were achieved. The feasibility of the method was demonstrated by analyzing human urine samples.

  18. A multiresidue method by high performance liquid chromatography-based fractionation and gas chromatographic determination of trace levels of pesticides in air and water.

    Science.gov (United States)

    Seiber, J N; Glotfelty, D E; Lucas, A D; McChesney, M M; Sagebiel, J C; Wehner, T A

    1990-01-01

    A multiresidue analytical method is described for pesticides, transformation products, and related toxicants based upon high performance liquid chromatographic (HPLC) fractionation of extracted residue on a Partisil silica gel normal phase column followed by selective-detector gas chromatographic (GC) determination of components in each fraction. The HPLC mobile phase gradient (hexane to methyl t-butyl ether) gave good chromatographic efficiency, resolution, reproducibility and recovery for 61 test compounds, and allowed for collection in four fractions spanning polarities from low polarity organochlorine compounds (fraction 1) to polar N-methylcarbamates and organophosphorus oxons (fraction 4). The multiresidue method was developed for use with air samples collected on XAD-4 and related trapping agents, and water samples extracted with methylene chloride. Detection limits estimated from spiking experiments were generally 0.3-1 ng/m3 for high-volume air samples, and 0.01-0.1 microgram/L for one-liter water samples. Applications were made to determination of pesticides in fogwater and air samples.

  19. Evolved gas composition monitoring by repetitive injection gas chromatography.

    Science.gov (United States)

    White, Robert L

    2015-11-20

    Performance characteristics and applications of a small volume gas chromatograph oven are described. Heating and cooling properties of the apparatus are evaluated and examples are given illustrating the advantages of greatly reducing the air bath volume surrounding fused silica columns. Fast heating and cooling of the oven permit it to be employed for repetitive injection analyses. By using fast gas chromatography separations to achieve short assay cycle times, the apparatus can be employed for on-line species-specific gas stream composition monitoring when volatile species concentrations vary on time scales of a few minutes or longer. This capability facilitates repeated sampling and fast gas chromatographic separations of volatile product mixtures produced during thermal analyses. Applications of repetitive injection gas chromatography-mass spectrometry evolved gas analyses to monitoring purge gas effluent streams containing volatile acid catalyzed polymer cracking products are described. The influence of thermal analysis and chromatographic experimental parameters on effluent sampling frequency are delineated. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Determination of N-nitrosamines in processed meats by liquid extraction combined with gas chromatography-methanol chemical ionisation/mass spectrometry.

    Science.gov (United States)

    Scheeren, Marina Bergoli; Sabik, Hassan; Gariépy, Claude; Terra, Nelcindo Nascimento; Arul, Joseph

    2015-01-01

    A simple, accessible and reproducible method was developed and validated as an alternative for the determination of nine volatile N-nitrosamines (NAs) in meat products, using a low volume of organic solvent and without requiring specific apparatus, offering the possibility of practical implementation in routine laboratories. The NAs were extracted with dichloromethane followed by a clean-up with phosphate buffer solution (pH 7.0). The extracts were analysed by gas chromatography-chemical ionisation/mass spectrometry (GC-CI/MS) in positive-ion mode using methanol as reagent. Limits of detection and quantification, recovery and reproducibility were determined for all NAs (N-nitrosodimethylamine, N-nitrosomethylethylamine, N-nitrosodiethylamine, N-nitrosopyrrolidine, N-nitrosodipropylamine, N-nitrosomorpholine, N-nitrosopiperidine, N-nitrosodibutylamine and N-nitrosodiphenylamine). Satisfactory sensitivity and selectivity were obtained even without concentrating the extract by solvent evaporation, avoiding the loss of the nine NAs studied. Limits of detection ranged from 0.15 to 0.37 µg kg(-1), whereas limits of quantification ranged from 0.50 to 1.24 µg kg(-1). Recoveries calculated in cooked ham that had been spiked at 10 and 100 µg kg(-1) were found to be between 70% and 114% with an average relative standard deviation of 13.2%. The method was successfully used to analyse five samples of processed meat products on the day of purchase and 7 days later (after storage at 4°C). The most abundant NAs found in the analysed products were N-nitrosodipropylamine and N-nitrosopiperidine, which ranged from 1.75 to 34.75 µg kg(-1) and from 1.50 to 4.26 µg kg(-1), respectively. In general, an increase in the level of NAs was observed after the storage period. The proposed method may therefore be a useful tool for food safety control once it allows assessing the profile and the dietary intake of NAs in food over time.

  1. Permanent gas analysis using gas chromatography with vacuum ultraviolet detection.

    Science.gov (United States)

    Bai, Ling; Smuts, Jonathan; Walsh, Phillip; Fan, Hui; Hildenbrand, Zacariah; Wong, Derek; Wetz, David; Schug, Kevin A

    2015-04-03

    The analysis of complex mixtures of permanent gases consisting of low molecular weight hydrocarbons, inert gases, and toxic species plays an increasingly important role in today's economy. A new gas chromatography detector based on vacuum ultraviolet (VUV) spectroscopy (GC-VUV), which simultaneously collects full scan (115-240 nm) VUV and UV absorption of eluting analytes, was applied to analyze mixtures of permanent gases. Sample mixtures ranged from off-gassing of decomposing Li-ion and Li-metal batteries to natural gas samples and water samples taken from private wells in close proximity to unconventional natural gas extraction. Gas chromatography separations were performed with a porous layer open tubular column. Components such as C1-C5 linear and branched hydrocarbons, water, oxygen, and nitrogen were separated and detected in natural gas and the headspace of natural gas-contaminated water samples. Of interest for the transport of lithium batteries were the detection of flammable and toxic gases, such as methane, ethylene, chloromethane, dimethyl ether, 1,3-butadiene, CS2, and methylproprionate, among others. Featured is the capability for deconvolution of co-eluting signals from different analytes. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Trends in High Performance Liquid Chromatography for Cultural Heritage.

    Science.gov (United States)

    Degano, Ilaria; La Nasa, Jacopo

    2016-04-01

    The separation, detection and quantitation of specific species contained in a sample in the field of Cultural Heritage requires selective, sensitive and reliable methods. Procedures based on liquid chromatography fulfil these requirements and offer a wide range of applicability in terms of analyte types and concentration range. The main applications of High Performance Liquid Chromatography in this field are related to the separation and detection of dyestuffs in archaeological materials and paint samples by reversed-phase liquid chromatography with suitable detectors. The relevant literature will be revised, with particular attention to sample treatment strategies and future developments. Reversed phase chromatography has also recently gained increasing importance in the analysis of lipid binders and lipid materials in archaeological residues: the main advantages and disadvantages of the new approaches will be discussed. Finally, the main applications of ion chromatography and size exclusion chromatography in the field of Cultural Heritage will be revised in this chapter.

  3. Comprehensive Gas Chromatography: Food and Metabolomocs Applications.

    Science.gov (United States)

    Strączyński, Grzegorz; Ligor, Tomasz

    2017-10-30

    Since the comprehensive two-dimensional gas chromatography (GC × GC) technique is becoming more and more available for scientists as well as for laboratories performing routine analyses, the most successful field of applications are petrochemical, food and essential oil analysis. However, this technique coupled with TOF-MS (P.1, l. 27) could be even more successfully used in the field of metabolomics. The review presents briefly the concept of comprehensive 2D GC and the principles of the technique. Certain specific applications are discussed to show the usefulness of GC × GC combined with different detectors for determination of compounds not always easy to measure with other techniques.

  4. Application of dynamic liquid-phase microextraction and injection port derivatization combined with gas chromatography-mass spectrometry to the determination of acidic pharmaceutically active compounds in water samples.

    Science.gov (United States)

    Zhang, Jie; Lee, Hian Kee

    2009-10-30

    A method has been established for the determination of four pharmaceutically active compounds (ibuprofen, ketoprofen, naproxen and clofibric acid) in water samples using dynamic hollow fiber liquid-phase microextraction (HF/LPME) followed by gas chromatography (GC) injection port derivatization and GC-mass spectrometric (MS) determination. Dynamic HF/LPME is a novel approach to microextraction that involves the use of a programmable syringe pump to move the liquid phases participating in the extraction so as to facilitate the process. Trimethylanilinium hydroxide (TMAH) was used as derivatization reagent for the analytes to increase their volatility and improve chromatographic separation. Parameters that affect extraction efficiency (selection of organic solvent, volume of organic solvent, agitation in the donor phase, plunger movement and extraction time) were investigated. Under optimal conditions, the proposed method provided good enrichment factors up to 251, reproducibility ranging from 3.26% to 10.61%, and good linearity from 0.2 to 50 microg/L. The limits of detection ranged between 0.01 and 0.05 microg/L (S/N=3) using selective ion monitoring. This method was applied to the determination of the four pharmaceutically active compounds in tap water and wastewater collected from a drain in the vicinity of a hospital.

  5. Liquid Chromatography Applied to Space System

    Science.gov (United States)

    Poinot, Pauline; Chazalnoel, Pascale; Geffroy, Claude; Sternberg, Robert; Carbonnier, Benjamin

    , etc.) which are good examples for one of the two intrinsic features of life (i.e. complexity) would then be searched for. Although these methods are very promising as they have already demonstrated real benefits in terms of sensitivity towards specific compounds of middle/high molecular weight, they cannot be used to detect in one pot a wide range of biopolymer targets with very diverse nature, such as peptides or oligonucleotides. In this context, it would be interesting to develop a “micro-lab” equipped with a miniaturized HPLC-MS as the ones currently developed in the field of biological and medicinal sciences. The objective is to demonstrate unequivocally the presence or absence in space of a wide range of biopolymers thanks to a “one step one pot” instrumentation. We propose to demonstrate the feasibility and the validity of such a concept. For that, we optimize the chromatographic conditions and the mass spectrometer parameters to detect in the range of ppb, proteins and polypeptides biomarkers, while taking into account the space constraints. On a UPLC-HRMS (Q-Exactive and Qq-TOF), different stationary phases (laboratory-made or commercially available), different eluents, gradient flows, temperatures, pressures, and the use of a pre-concentration stage are tested. Dual detection (MS and diode array) is also considered. First experiments have highlighted the ability of such a technique to find ultra-traces level of organic matters under definite space constraints (elution flow, solvents, temperature...). This work is funded by the French Space Agency (CNES) References Glavin DP, Schubert Ml, Botta O, Kminek G, Bada JL (2001) Detecting pyrolysis products from bacteria on Mars. Earth Planet Sc Lett 185:1-2. doi:10.1016/S0012-821X(00)00370-8 Navarro-González R, Navarro KF, de la Rosa J, Iñliguez E, Molina P, Mira LD (2006) The limitations on organic detection in Mars-like soils by thermal volatilization-gas chromatography-MS and their implications for the

  6. Hydrophilic interaction liquid chromatography (HILIC) in proteomics

    OpenAIRE

    Boersema, Paul J.; Mohammed, Shabaz; Heck, Albert J. R.

    2008-01-01

    In proteomics, nanoflow multidimensional chromatography is now the gold standard for the separation of complex mixtures of peptides as generated by in-solution digestion of whole-cell lysates. Ideally, the different stationary phases used in multidimensional chromatography should provide orthogonal separation characteristics. For this reason, the combination of strong cation exchange chromatography (SCX) and reversed-phase (RP) chromatography is the most widely used combination for the separa...

  7. Clinical applications of gas chromatography and gas chromatography-mass spectrometry of steroids

    NARCIS (Netherlands)

    Wolthers, BG; Kraan, GPB

    1999-01-01

    This review article underlines the importance of gas chromatography-mass spectrometry (GC-MS) for determination of steroids in man. The use of steroids labelled with stable isotopes as internal standard and subsequent analysis by GC-MS yields up to now the only reliable measurement of steroids in

  8. A comprehensive procedure based on gas chromatography-isotope ratio mass spectrometry following high performance liquid chromatography purification for the analysis of underivatized testosterone and its analogues in human urine

    Energy Technology Data Exchange (ETDEWEB)

    Torre, Xavier de la, E-mail: xavier.delatorre@gmail.com [Laboratorio Antidoping, Federazione Medico Sportiva Italiana, Largo Giulio Onesti 1, 00197 Rome (Italy); Colamonici, Cristiana; Curcio, Davide; Molaioni, Francesco [Laboratorio Antidoping, Federazione Medico Sportiva Italiana, Largo Giulio Onesti 1, 00197 Rome (Italy); Botre, Francesco [Laboratorio Antidoping, Federazione Medico Sportiva Italiana, Largo Giulio Onesti 1, 00197 Rome (Italy); Dipartimento di Management, ' Sapienza' Universita di Roma, Via del Castro Laurenziano 9, 00161 Rome (Italy)

    2012-12-05

    Highlights: Black-Right-Pointing-Pointer Overall approach for urine samples purification by HPLC for subsequent GC/C/IRMS analysis in doping control. Black-Right-Pointing-Pointer Detection of pseudo-endogenous androgenic steroids (i.e. testosterone, androstenedione) misuse in sports. Black-Right-Pointing-Pointer Routine analysis of steroids by GC/C/IRMS in sports drug testing. - Abstract: The confirmation by GC/C/IRMS of the exogenous origin of pseudo-endogenous steroids from human urine samples requires extracts of adequate purity. A strategy based on HPLC sample purification prior to the GC/C/IRMS analysis of human urinary endogenous androgens (i.e. testosterone, androsterone and/or androstenediols), is presented. A method without any additional derivatization step is proposed, allowing to simplify the urine pretreatment procedure, leading to extracts free of interferences permitting precise and accurate IRMS analysis, without the need of correcting the measured delta values for the contribution of the derivatizing agent. The HPLC extracts were adequately combined to both reduce the number of GC/C/IRMS runs and to have appropriate endogenous reference compounds (ERC; i.e. pregnanediol, 11-keto-etiocholanolone) on each GC-IRMS run. The purity of the extracts was assessed by their parallel analysis by gas chromatography coupled to mass spectrometry, with GC conditions identical to those of the GC/C/IRMS assay. The method has been validated according to ISO17025 requirements (within assay precision below 0.3 Per-Mille-Sign {sup 13}C delta units and between assay precision below 0.6 Per-Mille-Sign {sup 13}C delta units for most of the compounds investigated) fulfilling the World Anti-Doping Agency requirements.

  9. Parallel comprehensive two-dimensional gas chromatography.

    Science.gov (United States)

    Yan, DanDan; Tedone, Laura; Koutoulis, Anthony; Whittock, Simon P; Shellie, Robert A

    2017-11-17

    We introduce an information rich analytical approach called parallel comprehensive two-dimensional gas chromatography (2GC×2GC). This parallel chromatography approach splits injected samples into two independent two-dimensional column ensembles and provides two GC×GC separations by using contra-directional thermal modulation. The first-dimension ( 1 D) and second-dimension ( 2 D) columns are connected using planar three-port microchannel devices, which are supplied with supplementary flow via two pressure controller modules. Precise carrier gas flow control at the junction of the 1 D and 2 D columns permits independent control of flow conditions in each separation column. The 2GC×2GC approach provides two entirely independent GC×GC separations for each injection. Analysis of hop (Humulus lupulus L.) essential oils is used to demonstrate the capability of the approach. The analytical performance of each GC×GC separation in the 2GC×2GC experiment is comparable to individual GC×GC separation with matching column configurations. The peak capacity of 2GC×2GC is about 2 times than that of single GC×GC system. The dual 2D chromatograms produced by this single detector system provide complementary separations and additional identification information by harnessing different selectivity provided by the four separation columns. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Simultaneous analysis for water- and fat-soluble vitamins by a novel single chromatography technique unifying supercritical fluid chromatography and liquid chromatography.

    Science.gov (United States)

    Taguchi, Kaori; Fukusaki, Eiichiro; Bamba, Takeshi

    2014-10-03

    Chromatography techniques usually use a single state in the mobile phase, such as liquid, gas, or supercritical fluid. Chromatographers manage one of these techniques for their purpose but are sometimes required to use multiple methods, or even worse, multiple techniques when the target compounds have a wide range of chemical properties. To overcome this challenge, we developed a single method covering a diverse compound range by means of a "unified" chromatography which completely bridges supercritical fluid chromatography and liquid chromatography. In our method, the phase state was continuously changed in the following order; supercritical, subcritical and liquid. Moreover, the gradient of the mobile phase starting at almost 100% CO2 was replaced with 100% methanol at the end completely. As a result, this approach achieved further extension of the polarity range of the mobile phase in a single run, and successfully enabled the simultaneous analysis of fat- and water-soluble vitamins with a wide logP range of -2.11 to 10.12. Furthermore, the 17 vitamins were exceptionally separated in 4min. Our results indicated that the use of dense CO2 and the replacement of CO2 by methanol are practical approaches in unified chromatography covering diverse compounds. Additionally, this is a first report to apply the novel approach to unified chromatography, and can open another door for diverse compound analysis in a single chromatographic technique with single injection, single column and single system. Copyright © 2014. Published by Elsevier B.V.

  11. Microchip-based monolithic column for high performance liquid chromatography

    Data.gov (United States)

    National Aeronautics and Space Administration — We have developed microchip based monolithic columns that can be used for liquid chromatography of small organic molecules, as well as, macromolecules such as...

  12. Ionization of Gas-Phase Polycyclic Aromatic Hydrocarbons in Electrospray Ionization Coupled with Gas Chromatography.

    Science.gov (United States)

    Cha, Eunju; Jeong, Eun Sook; Han, Sang Beom; Cha, Sangwon; Son, Junghyun; Kim, Sunghwan; Oh, Han Bin; Lee, Jaeick

    2018-03-20

    Herein, gas-phase polycyclic aromatic hydrocarbons (PAHs) as nonpolar compounds were ionized to protonated molecular ions [M + H] + without radical cations and simultaneously analyzed using gas chromatography (GC)/electrospray ionization (ESI)-tandem mass spectrometry (MS/MS). The ionization profile, dissociation, and sensitivity were first investigated to understand the significant behavior of gas-phase PAHs under ESI. The formation of protonated molecular ions of PAHs was distinguished according to the analyte phase and ESI spray solvents. The protonated PAHs exhibited characteristic dissociations, such as H-loss, H 2 -loss, and acetylene-loss, via competition of internal energy. In addition, GC/ESI-MS/MS resulted in relatively lower concentration levels (better sensitivity) for the limits-of-detection (LODs) of PAHs than liquid chromatography (LC)/ESI-MS/MS, and it seems to result from the characteristic ionization mechanism of the gas-phase analyte under ESI. Furthermore, the LODs of gas-phase PAHs depended on molecular weight and proton affinity (PA). Consequently, we demonstrated the relationship among the analyte phases, sensitivities, and structural characteristics (molecular weight and PA) under ESI. The gas-phase PAHs provided enhanced protonation efficiency and sensitivity using GC/ESI-MS/MS, as their molecular weight and PA increased. Based on these results, we offered important information regarding the behavior of gas-phase analytes under ESI. Therefore, the present GC/ESI-MS/MS method has potential as an alternative method for simultaneous analysis of PAHs.

  13. Nano-Optomechanical Systems for Gas Chromatography.

    Science.gov (United States)

    Venkatasubramanian, Anandram; Sauer, Vincent T K; Roy, Swapan K; Xia, Mike; Wishart, David S; Hiebert, Wayne K

    2016-11-09

    Microgas chromatography (GC) is promising for portable chemical analysis. We demonstrate a nano-optomechanical system (NOMS) as an ultrasensitive mass detector in gas chromatography. Bare, native oxide, silicon surfaces are sensitive enough to monitor volatile organic compounds at ppm levels, while simultaneously demonstrating chemical selectivity. The NOMS is able to sense GC peaks from derivatized metabolites at physiological concentrations. This is an important milestone for small-molecule quantitation assays in next generation metabolite analyses for applications such as disease diagnosis and personalized medicine. The optical microring, which plays an important role in the nanomechanical signal transduction mechanism, can also be used as an analyte concentration sensor. Different adsorption kinetics regimes are realized at different temperatures allowing temporary condensation of the analyte onto the sensor surfaces. This effect amplifies the signal, resulting in a 1 ppb level limit of detection, without partition enhancement from absorbing media. This sensitivity bodes well for NOMS as universal, ultrasensitive detectors in micro-GC, breath analysis, and other chemical-sensing applications.

  14. Transient gas jets into liquids

    Science.gov (United States)

    Lin, Jane Ming-Chin

    An experimental investigation of the development of high velocity, impulsively initiated gas jets into liquid was conducted in an effort to understand some of the physical processes that occur for a jet of very light fluid into a dense ambient atmosphere. Four gases, refrigerants 12 and 22, nitrogen, and helium were injected into water at nozzle exit Mach numbers from 1.0 to 2.2.The study showed that a gas jet into water develops in at least three stages: startup, transition, and global steady state. The startup is characterized by bubble growth; the growth rate is well predicted by classical bubble-growth theory. Jet transition is marked by axially directed flow, which penetrates through the startup bubble and which forms a cylindrical protrusion along the axis of symmetry. A combination of strong recirculating flow and liquid entrainment causes the startup bubble to deflate and to lift off and move downstream. In the steady state, instantaneous photographs show small-scale fluctuations of the jet boundary, but time-averaged photographs show the expected conical spreading of the steady jet; the measured spreading angles range from 18-25 degrees.However, the most significant finding of this study is that under some conditions, the gas jet into liquid never reaches the global steady state. Instead, the jet boundary exhibits chugging: large nonlinear oscillations which lead to irregular collapses of the gas column followed by explosive outward bursts of gas. The unsteadiness observed is much more violent than the familiar fluctuations typical of constant-density jets. The length scale of the motion is generally on the order of several jet diameters; the time scale is on the order of the period for bubble collapse.It was found that the amplitude and frequency of chugging are strongly dependent on the ratio of the liquid density to the gas density, the jet Mach number, and the operating pressure ratio. The conditions under which unsteadiness occurs were determined

  15. Determination of polar organophosphorus pesticides in vegetables and fruits using liquid chromatography with tandem mass spectrometry: Selection of extraction solvent

    NARCIS (Netherlands)

    Mol, H.G.J.; Dam, R.C.J. van; Steijger, O.M.

    2003-01-01

    A method based on liquid chromatography (LC)-mass spectrometry (MS)/MS was developed for sensitive determination of a number of less gas chromatography (GC)-amenable organophosphorus pesticides (OPs; acephate, methamidophos, monocrotophos, omethoate, oxydemeton-methyl and vamidothion) in cabbage and

  16. Simultaneous derivatization and extraction of primary amines in river water with dynamic hollow fiber liquid-phase microextraction followed by gas chromatography-mass spectrometric detection.

    Science.gov (United States)

    Chia, Kan-Jung; Huang, Shang-Da

    2006-01-20

    A one-step derivatization and extraction technique for the determination of primary amines in river water by liquid-phase microextraction (LPME) is presented. In this method the primary amines are derivatized with pentafluorobenzaldehyde (PFBAY) in aqueous solution and extracted by dynamic hollow fiber-protected-LPME (HF-LPME) simultaneously. The effects of solvent selection, sample agitation, extraction time, extraction temperature and salt concentration on the extraction performance are investigated. High enrichments (172-244-fold) and good repeatabilities (RSD less than 7.2%) were obtained. Linearity in this developed method was ranging from 1 to 500 ng/ml, and the correlation coefficients (R2) were between 0.992 and 0.998. Comparisons of sensitivity and precision between dynamic HF-LPME and single-drop liquid-phase microextraction (SDME) were also made.

  17. Determination of degradation products of chemical warfare agents in water using hollow fibre-protected liquid-phase microextraction with in-situ derivatisation followed by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Lee, Hoi Sim Nancy; Sng, Mui Tiang; Basheer, Chanbasha; Lee, Hian Kee

    2007-04-27

    Hollow fibre-protected liquid-phase microextraction (HF-LPME) together with gas chromatography/mass spectrometry was investigated for the analysis of degradation products of chemical warfare agents in water samples. The degradation products studied were those of nerve and blister agents, and a psychotomimetic agent. Extractions were successfully performed coupled with in-situ derivatisation using a mixture of solvent and derivatising agent. The protection of the moisture-sensitive derivatising agent was afforded by the hollow fibre. Parameters such as extraction solvent, pH, salt concentration, stirring speed and extraction time were optimised using spiked deionised water samples. The linear range established was between 0.005 and 5 microg ml(-1) depending on analyte, with squared regression coefficients ranging from 0.9929 to 1.0000. Relative standard deviations ranged from 9% to 22%. As compared to those of solid-phase microextraction, the limits of detection (0.01-0.54 microg l(-1)) of the newly-developed approach were significantly improved.

  18. Headspace hollow fiber protected liquid-phase microextraction combined with gas chromatography-mass spectroscopy for speciation and determination of volatile organic compounds of selenium in environmental and biological samples.

    Science.gov (United States)

    Ghasemi, Ensieh; Sillanpää, Mika; Najafi, Nahid Mashkouri

    2011-01-21

    A simple and novel speciation method for the determination of volatile organic compounds of selenium (dimethylselenide (DMSe) and dimethyldiselenide (DMDSe) has been developed using a headspace hollow fiber protected liquid-phase microextraction (HS-HF-LPME) combined with capillary gas chromatography-mass spectrometry (GC-MS). The organic solvent impregnated in the pores and filled inside the porous hollow fiber membrane was used as an extraction interface in the HS-HF-LPME of the compounds. The effect of different variables on the extraction efficiency was studied simultaneously using an experimental design. The variables of interest in the HS-HF-LPME were sample volume, extraction time, temperature of sample solution, ionic strength, stirring rate and dwelling time. A Plackett-Burman design was performed for screening in order to determine the significant variables affecting the extraction efficiency. Then, the significant factors were optimized by a Box-Behnken design (BBD) and the response surface equations were derived. Under optimum conditions, preconcentration factors up to 1250 and 1170 were achieved for DMSe and DMDSe respectively. The detection limit and relative standard deviation (RSD) (n=5, c=50 μg L(-1)) for DMSe were 65 ng L(-1) and 4.8%, respectively. They were also obtained for DMDSe as 57 ng L(-1) and 3.9%, respectively. The developed technique was found to be applicable to spiked environmental and biological samples. Copyright © 2010 Elsevier B.V. All rights reserved.

  19. A novel poly(3,4-ethylenedioxythiophene)-ionic liquid composite coating for the headspace solid-phase microextraction and gas chromatography determination of several alcohols in soft drinks.

    Science.gov (United States)

    Wu, Mian; Zhang, Haibo; Zhao, Faqiong; Zeng, Baizhao

    2014-11-19

    A novel poly(3,4-ethylenedioxythiophene)-ionic liquid (i.e., 1-hydroxyethyl-3-methyl imidazolium-bis[(trifluoromethyl)sulfonyl]imide) composite film was electrodeposited on a Pt wire for headspace solid-phase microextraction. The film showed nodular structure and had large specific surface. In addition, it displayed high thermal stability (up to 300°C) and durable property (could be used for more than 200 times). Coupled with gas chromatography-flame ionization detection, the resulting fiber was applied to the headspace solid-phase microextraction and determination of several alcohols (i.e., linalool, nonanol, terpineol, geraniol, decanol and dodecanol). It presented higher extraction capability in comparison with the poly(3,4-ethylenedioxythiophene) and commercial polydimethylsiloxane/divinylbenzene fiber. Under the optimized conditions, the linear ranges exceeded three magnitudes with correlation coefficients above 0.9952 and the low limits of detection were 34.2-81.3ng L(-1). For different alcohols the repeatabilities (defined as RSD) were alcohols in real samples with acceptable recoveries from 81.1% to 106.6%. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Characterization of cis- and trans-octadecenoic acid positional isomers in edible fat and oil using gas chromatography-flame ionisation detector equipped with highly polar ionic liquid capillary column.

    Science.gov (United States)

    Yoshinaga, Kazuaki; Asanuma, Masaharu; Mizobe, Hoyo; Kojima, Koichi; Nagai, Toshiharu; Beppu, Fumiaki; Gotoh, Naohiro

    2014-10-01

    In this study, the characterisation of all cis- and trans-octadecenoic acid (C18:1) positional isomers in partially hydrogenated vegetable oil (PHVO) and milk fat, which contain several cis- and trans-C18:1 positional isomers, was achieved by gas chromatography-flame ionisation detector equipped with a highly polar ionic liquid capillary column (SLB-IL111). Prior to analysis, the cis- and trans-C18:1 fractions in PHVO and milk fat were separated using a silver-ion cartridge. The resolution of all cis-C18:1 positional isomers was successfully accomplished at the optimal isothermal column temperature of 120 °C. Similarly, the positional isomers of trans-C18:1, except for trans-6-C18:1 and trans-7-C18:1, were separated at 120 °C. The resolution of trans-6-C18:1 and trans-7-C18:1 isomers was made possible by increasing the column temperature to 160 °C. This analytical method is suitable for determining the cis- and trans-C18:1 positional isomers in edible fats and oils. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Stir-bar-sorptive extraction and liquid desorption combined with large-volume injection gas chromatography-mass spectrometry for ultra-trace analysis of musk compounds in environmental water matrices.

    Science.gov (United States)

    Silva, Ana Rita M; Nogueira, J M F

    2010-03-01

    Stir-bar-sorptive extraction with liquid desorption followed by large-volume injection and capillary gas chromatography coupled to mass spectrometry in selected ion monitoring acquisition mode (SBSE-LD/LVI-GC-MS(SIM)) has been developed to monitor ultra-traces of four musks (celestolide (ADBI), galaxolide (HHCB), tonalide (AHTN) and musk ketone (MK)) in environmental water matrices. Instrumental calibration (LVI-GC-MS(SIM)) and experimental conditions that could affect the SBSE-LD efficiency are discussed. Assays performed on 30-mL water samples spiked at 200 ng L(-1) under optimized experimental conditions yielded recoveries ranging from 83.7 ± 8.1% (MK) to 107.6 ± 10.8% (HHCB). Furthermore, the experimental data were in very good agreement with predicted theoretical equilibria described by octanol-water partition coefficients (K (PDMS/W) ≈ K (O/W)). The methodology also showed excellent linear dynamic ranges for the four musks studied, with correlation coefficients higher than 0.9961, limits of detection and quantification between 12 and 19 ng L(-1) and between 41 and 62 ng L(-1), respectively, and suitable precision (ultra-trace level, overcoming several disadvantages presented by other sample-preparation techniques.

  2. Vacuum ultraviolet detector for gas chromatography.

    Science.gov (United States)

    Schug, Kevin A; Sawicki, Ian; Carlton, Doug D; Fan, Hui; McNair, Harold M; Nimmo, John P; Kroll, Peter; Smuts, Jonathan; Walsh, Phillip; Harrison, Dale

    2014-08-19

    Analytical performance characteristics of a new vacuum ultraviolet (VUV) detector for gas chromatography (GC) are reported. GC-VUV was applied to hydrocarbons, fixed gases, polyaromatic hydrocarbons, fatty acids, pesticides, drugs, and estrogens. Applications were chosen to feature the sensitivity and universal detection capabilities of the VUV detector, especially for cases where mass spectrometry performance has been limited. Virtually all chemical species absorb and have unique gas phase absorption cross sections in the approximately 120-240 nm wavelength range monitored. Spectra are presented, along with the ability to use software for deconvolution of overlapping signals. Some comparisons with experimental synchrotron data and computed theoretical spectra show good agreement, although more work is needed on appropriate computational methods to match the simultaneous broadband electronic and vibronic excitation initiated by the deuterium lamp. Quantitative analysis is governed by Beer-Lambert Law relationships. Mass on-column detection limits reported for representatives of different classes of analytes ranged from 15 (benzene) to 246 pg (water). Linear range measured at peak absorption for benzene was 3-4 orders of magnitude. Importantly, where absorption cross sections are known for analytes, the VUV detector is capable of absolute determination (without calibration) of the number of molecules present in the flow cell in the absence of chemical interferences. This study sets the stage for application of GC-VUV technology across a wide breadth of research areas.

  3. Doping control analysis of anabolic steroids in equine urine by gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Wong, April S Y; Leung, Gary N W; Leung, David K K; Wan, Terence S M

    2017-09-01

    Anabolic steroids are banned substances in equine sports. Gas chromatography-mass spectrometry (GC-MS) has been the traditional technique for doping control analysis of anabolic steroids in biological samples. Although liquid chromatography-mass spectrometry (LC/MS) has become an important technique in doping control, the detection of saturated hydroxysteroids by LC-MS remains a problem due to their low ionization efficiency under electrospray. The recent development in fast-scanning gas-chromatography-triple-quadrupole mass spectrometry (GC-MS/MS) has provided a better alternative with a significant reduction in chemical noise by means of selective reaction monitoring. Herein, we present a sensitive and selective method for the screening of over 50 anabolic steroids in equine urine using gas chromatography-tandem mass spectrometry (GC-MS/MS). Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  4. The comparison of chemical liquid deposition and acid dealumination modified ZSM-5 for catalytic pyrolysis of pinewood using pyrolysis-gas chromatography/mass spectrometry.

    Science.gov (United States)

    Zhang, Huiyan; Shao, Shanshan; Luo, Mengmeng; Xiao, Rui

    2017-11-01

    Catalyst deactivation is the main reason for low petrochemical yield in catalytic fast pyrolysis (CFP) of biomass. ZSM-5 catalysts modified by chemical liquid deposition (CLD) and acid dealumination (AD) were prepared to improve petrochemical yields for CFP of pinewood. The results showed that CLD by SiO 2 led to the coverage of strong acid sites, while AD favored the removal of superficial acid sites. CFP of pinewood showed that the relative area ratio of BTX was boosted by 37.2% and 30.4% over modified ZSM-5 catalysts by CLD and AD, respectively. The yield of indenes and naphthalenes which were important precursors of heavy coke decreased sharply. Considering environmental cost and catalytic performance, CLD seems to be a preferable modification method over ZSM-5 in the catalytic pyrolysis of biomass for petrochemicals. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Water-based gas purge microsyringe extraction coupled with liquid chromatography for determination of alkylphenols from sea food Laminaria japonica Aresh.

    Science.gov (United States)

    Yang, Cui; Zhao, Jinhua; Wang, Juan; Yu, Hongling; Piao, Xiangfan; Li, Donghao

    2013-07-26

    A novel organic solvent-free mode of gas purge microsyringe extraction, termed water-based gas purge microsyringe extraction, was developed. This technique can directly extract target compounds in wet samples without any drying process. Parameters affecting the extraction efficiency were investigated. Under optimal extraction conditions, the recoveries of alkylphenols were between 87.6 and 105.8%, and reproducibility was between 5.2 and 12.1%. The technique was also used to determine six kinds of alkylphenols (APs) from samples of Laminaria japonica Aresh. The OP and NP were detected in all the samples, and concentrations ranged from 26.0 to 54.5ngg(-1) and 45.0-180.4ngg(-1), respectively. The 4-n-butylphenol was detected in only one sample and its concentration was very low. Other APs were not detected in L. japonica Aresh samples. The experimental results demonstrated that the technique is fast, simple, non-polluting, allows for quantitative extraction, and a drying process was not required for wet samples. Since only aqueous solution and a conventional microsyringe were used, this technique proved affordable, efficient, and convenient for the extraction of volatile and semivolatile ionizable compounds. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Determination of polychlorinated biphenyls and polychlorinated dibenzo-p-dioxins and dibenzofurans by pressurized liquid extraction and gas chromatography coupled to mass spectrometry in street dust samples.

    Science.gov (United States)

    Klees, Marcel; Hiester, Ernst; Bruckmann, Peter; Schmidt, Torsten C

    2013-07-26

    Owing to massive pollution with polychlorinated biphenyls in the harbour area of Dortmund (Germany), several dust samples were taken from surfaces at industrial sites and analyzed by the North-Rhine Westphalian State Agency for Nature, Environment, and Consumer Protection (LANUV NRW). This report describes and validates a rapid approach to screening for the presence of polychlorinated biphenyls (PCBs) in street dust. Samples were collected by using a natural bristle brush and stainless steel scoops. Mass recovery of fine-particle sea sand (a dust surrogate) on asphalt and concrete surfaces was used as a criterion for the effectiveness of sampling. Better recoveries of sea sand were achieved on concrete than on asphalt surfaces. Furthermore, temperature optimization for a pressurized liquid extraction (PLE) method used to extract PCBs and polychlorinated dibenzodioxins and polychlorinated furans (PCDD/Fs) from street dust samples was developed and compared with Soxhlet extraction for the analysis of PCBs in real street dust samples. Toluene was used as the extraction solvent in both cases. During this study, a combination of toluene and PLE achieved better extraction efficiencies than Soxhlet extraction. Finally, the performance of the PLE method was evaluated by analysing NIST Standard Reference Material 1649a for PCB and PCDD/F concentrations. This demonstrated that the accuracy of the PLE method for the determination of both substance classes was satisfactory. In addition, concentrations of PCBs and PCDD/Fs in street dust samples from industrial sites are reported. Copyright © 2013. Published by Elsevier B.V.

  7. Determination of trace benzene derivatives in aqueous samples by ultrasonic enhanced hollow fiber liquid-phase microextraction prior to gas chromatography.

    Science.gov (United States)

    Wang, Lei; Guo, Yugao; Liang, Shumei; Yang, Qingqing; Wei, Junfu

    2011-10-01

    A new method was developed for the determination of trace compounds in water samples using ultrasonic-enhanced hollow fiber liquid-phase microextraction (U-HF-LPME). The ultrasonic radiation, which produces mechanical vibration and ultrasonic cavitation, could be used for accelerating the diffusion mass transfer process. Thus, ultrasonic was introduced into the HF-LPME procedure to enhance the mass-transfer rate during the aqueous and extraction solvent phases. Experimental parameters such as the extraction solvent, the extraction time, the ultrasonic frequency and power, the extractant volume, and ionic strength of the sample were assessed and optimized. Under optimal conditions, HF-LPME was achieved within 10 min. The high enrichment factor in the range of 120-666 and a good relative recovery in the range of 97-103% were evaluated with the relative standard deviations (RSDs, n = 5) of 0.3-7.0%. The limit of detection was in the range of 0.8-3.0 µg/L. The method was applied to the analysis of groundwater, lake water, and seawater. The results showed that the method can determine trace benzene derivatives in real samples with RSD values of 1.1-4.2%. The results demonstrated that U-HF- LPME is a rapid, accurate, and effective sample preparation method, and could be successfully applied for the determination of trace compounds in analytical chemistry.

  8. Hollow fiber liquid-phase microextraction as clean-up step for the determination of organophosphorus pesticides residues in fish tissue by gas chromatography coupled with mass spectrometry.

    Science.gov (United States)

    Sun, Xiaojin; Zhu, Fang; Xi, Jiabin; Lu, Tongbu; Liu, Hong; Tong, Yexiang; Ouyang, Gangfeng

    2011-01-01

    Hollow fiber liquid-phase microextraction (HF-LPME) technique was used as a clean-up procedure for the determination of organophosphorus pesticides (OPPs) in fish tissue. In this study, eight OPPs were first extracted with acetone from fish sample, the organic extract after rotatory evaporation was then redissolved with water-methanol (95:5, v/v) solution, followed by polyvinylidene difluoride (PVDF) HF-LPME. Experimental HF-LPME and other sample preparation conditions were carefully investigated and optimized. Under the optimum conditions, good linearity were observed in the range of 20-500 ng/g, limits of detections (LODs) were in the range of 2.1-4.5 ng/g. The repeatability and recovery of the method also showed satisfactory results. Compared with traditional sample preparation method for the determination of OPPs in fish tissue, the method developed in this study eliminated the solid phase extraction (SPE) step, simplified the sample preparation procedure and lowered the cost of analysis. Copyright © 2011 Elsevier Ltd. All rights reserved.

  9. Rapid actinide analysis method coupling liquid chromatography/ICP-MS and 90Sr gas proportional counter in post-accidental situation environmental samples

    International Nuclear Information System (INIS)

    Habibi, Azza

    2015-01-01

    The present study follows the Fukushima power plant accident and aimed to develop an analytical method to achieve, during an emergency situation, a rapid identification and quantification of alpha and beta emitters in environmental samples. The first step of this study allowed us to list the alpha and beta emitters which can be released in the environment in case of a nuclear accident. The second step aimed towards the development of a rapid analysis method to quantify 17 radionuclides of U, Th, Pu, Am, Np and Sr. The main objective was the automation of the radiochemical separation step and its coupling for the measurement. The separation is performed using columns containing extraction resins, namely TEVA, TRU and Sr. The measurement is performed using an ICP-MS (inductively coupled plasma mass spectrometry) and in some cases a gas proportional counter to quantify radiostrontium ( 89 Sr and 90 Sr). Excellent figures of merit were obtained, off line, with water (tap, river and sea water) and solid matrices (soil and aerosol filters), after a micro-wave digestion or an alkaline fusion dissolution followed by a Ca 3 (PO 4 ) 2 coprecipitation. The proposed analytical strategy showed yields between 70 % and 100 % and standard deviations between 5 % and 10 %. The newly developed separation method was then automated and coupled on-line to ICP-MS. The operating parameters were optimized using a design of experiments and the results were processed with Minitab. The optimized automated separation coupled on-line to the ICP-MS allows the rapid quantification, in 1.5 h per sample, of U, Th, Pu, Am, Np and Sr with detection limits gain as high as 20 times for artificial radionuclide. (author)

  10. Analysis of beta-agonists and beta-blockers in urine using hollow fibre-protected liquid-phase microextraction with in situ derivatization followed by gas chromatography/mass spectrometry.

    Science.gov (United States)

    Liu, Wei; Zhang, Lan; Wei, Zhenyi; Chen, Shengping; Chen, Guonan

    2009-07-10

    A method using hollow fibre-protected liquid-phase microextraction (HF-LPME) with in situ derivatization followed by gas chromatography/mass spectrometry (GC/MS) was established for the analysis of beta-agonists and beta-blockers in urine. Because it can simultaneously extract and derivatize compounds of interest by methylbenzol and N-methyl-N-(trimethylsilyl) trifluoroacetamide (MSTFA) in HF-LPME, the approach overcomes the drawbacks of considerable time-consuming and tedious operation, meanwhile improves enrichment multiple. The optimized conditions were extraction for 20 min at 35 degrees C with 5.0 microL of mixed extraction solvent (methylbenzol/MSTFA=1:1, v/v) with stirring speed of 925 rpm in 5.0 mL sample under pH 12.0 and 14% (w/v) NaCl. The method provided very wide linear ranges (0.25-400 ng mL(-1)) and low detection limits in the range of 0.08-0.10 ng mL(-1) for clenbuterol, metoprolol and propranolol while enrichment factors reached up to 256. The analytes could be determined in spiked urine by the method with high extraction efficacy (93.79-109.04% recoveries) and precision (<9.70% RSD). It has a satisfactory result for metoprolol in practical human urine samples for a single-dose administration of 50 mg after 36 h. The proposed method only needs few microliters of organic solvent and derivatizing agent; the operation is simple, convenient and rapid for the trace analysis of beta-agonists and beta-blockers in biological fluids; it can be readily generalized for high sample throughput. So, it is hopeful that the study will facilitate the monitoring of beta-agonists and beta-blockers in the competition sports.

  11. Determination of basic degradation products of chemical warfare agents in water using hollow fibre-protected liquid-phase microextraction with in-situ derivatisation followed by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Lee, Hoi Sim Nancy; Sng, Mui Tiang; Basheer, Chanbasha; Lee, Hian Kee

    2008-07-04

    Hollow fibre-protected liquid-phase microextraction (HF-LPME) together with gas chromatography-mass spectrometry was, for the first time, investigated for the in-situ derivatisation and analysis of basic degradation products of chemical warfare agents in water samples. The degradation products studied were those of nerve and blister agents, and a psychotomimetic agent. Extractions with in-situ derivatisation were successfully performed using a mixture of solvent and derivatising agent. The protection of the moisture-sensitive derivatising agent was afforded by the hydrophobic hollow fibre. Parameters such as type of derivatising agent, extraction solvent, pH, salt concentration, stirring speed and extraction time were optimised using spiked deionised water samples. The linear range established was between 0.05 and 25 microg ml(-1) depending on analyte, with squared regression coefficients ranging from 0.9959 to 0.9996. Relative standard deviations (RSDs) ranged from 6% to 10%. As comparison, solid-phase microextraction (SPME) was also evaluated and extraction conditions such as pH, salt concentration, stirring speed and extraction time were optimised. This work also represented the first report of such an in-situ derivatisation approach for SPME of basic analytes. The linear range established was between 0.5 and 25 microg ml(-1) depending on analyte, with squared regression coefficients ranging from 0.9946 to 0.9998. RSDs ranged from 5% to 22%. The limits of detection of HF-LPME (0.04-0.36 microg l(-1)) showed improvement over those of SPME (0.06-0.77 microg l(-1)).

  12. Hollow fiber liquid-phase microextraction with in situ derivatization combined with gas chromatography-mass spectrometry for the determination of root exudate phenylamine compounds in hot pepper ( Capsicum annuum L.).

    Science.gov (United States)

    Sun, Haiyan; Wang, Yan

    2013-06-12

    Hollow fiber liquid-phase microextraction (HF-LPME) with derivatization was developed for the determination of three root exudate phenylamine compounds in hot pepper ( Capsicum annuum L.) by gas chromatography-mass spectrometry (GC-MS). The performance and applicability of the proposed procedure were evaluated through the extraction of 1-naphthylamine (1-NA), diphenylamine (DPA), and N-phenyl-2- naphthaleneamine (N-P-2-NA) in a recirculating hydroponic solution of hot pepper. Parameters affecting the extraction efficiency were investigated. The calibration curves showed a good linearity in the range of 0.1-10 μg mL(-1). The limits of detection (S/N = 3) for the three compounds were 0.096, 0.074, and 0.057 μg mL(-1), respectively. The enrichment factors reached 174, 196, and 230 at the concentration of 5 μg mL(-1), and relative standard deviations (RSD) of 9.5, 8.6, and 7.8% and 8.4, 7.6, and 6.2% were obtained at concentrations of 2 and 5 μg mL(-1) for 1-NA, DPA, and N-P-2-NA, respectively. Recoveries ranging from 90.2 to 96.1% and RSDs below 9.1% were obtained when HF-LPME with in situ derivatization was applied to determine root exudate 1-NA, DPA, and N-P-2-NA after 15 and 30 days of culture solution, respectively.

  13. Determination of organophosphorus pesticides and metabolites in cereal-based baby foods and wheat flour by means of ultrasound-assisted extraction and hollow-fiber liquid-phase microextraction prior to gas chromatography with nitrogen phosphorus detection.

    Science.gov (United States)

    González-Curbelo, Miguel Ángel; Hernández-Borges, Javier; Borges-Miquel, Teresa María; Rodríguez-Delgado, Miguel Ángel

    2013-10-25

    A new method based on hollow-fiber liquid-phase microextraction (HF-LPME) has been developed for the determination of a group of organophosphorus pesticides, including some of their metabolites, in two commercial cereal-based baby foods and one wheat flour prior to gas chromatography-nitrogen phosphorus detection. Samples were first extracted by ultrasound-assisted extraction with acetonitrile (ACN) containing 1.25% (v/v) of formic acid. After evaporation and reconstitution in Milli-Q water, the HF-LPME procedure, using 1-octanol as extraction solvent, was applied followed by a desorption step in ACN, which clearly improved the performance of the technique. The effects of sample pH, ionic strength, stirring rate, extraction temperature and time as well as the desorption procedure were investigated. Under the optimum conditions that involved the extraction of the analytes from 10 mL of the water reconstituted extract at pH 7.0 containing 5% (w/v) of NaCl for 45 min at 960 rpm, the method was validated in terms of linearity, precision and accuracy. The limits of detection (LODs) were between 0.29 and 3.20 μg/kg. The extraction of Milli-Q water, as an example of the applicability of the procedure to aqueous samples, allowed achieving LODs in the range 0.01-0.04 μg/L. Such values, together with the ones achieved for the rest of the samples, are below or equal to the maximum residue limits specified by the European Union. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. On the use of ionic liquid capillary columns for analysis of aromatic hydrocarbons in low-boiling petrochemical products by one-dimensional and comprehensive two-dimensional gas chromatography.

    Science.gov (United States)

    Krupčík, Ján; Gorovenko, Roman; Špánik, Ivan; Bočková, Ingrid; Sandra, Pat; Armstrong, Daniel W

    2013-08-02

    One-dimensional and comprehensive two-dimensional flow modulated gas chromatography with simultaneous flame ionization and mass spectrometric detection were applied for the identification and quantification of benzene, toluene, ethyl benzene and xylenes (BTEX) as well as of all C9-C11 aromatic hydrocarbons in the low-boiling petroleum products gasoline, reformate and fluid catalytic cracking (FCC) samples. GC×GC experiments were performed on two reversed phase polarity column sets namely SLB-IL100 (25m×250μm i.d.×0.2μm df)+HP-5MS (5m×250μm i.d.×0.25μm df) and SLB-IL111 (30m×250μm i.d.×0.2μm df)+HP-5MS (5m×250μm i.d.×0.25μm df). The one-dimensional GC experiments were carried out on the same ionic liquid columns. The most powerful method is GC×GC on the SLB-111+HP-5MS column combination. Quantitative analysis of individual aromatic hydrocarbons (C6-C11) present in gasoline, reformate and fluid catalytic cracking (FCC) samples was performed by GC×GC-FID using the internal normalization method. Mass spectra obtained by GC×GC-qMSD were used for identification of the aromatic hydrocarbons in these samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Liquid chromatography and liquid chromatography-mass spectrometry analysis of donepezil degradation products

    Directory of Open Access Journals (Sweden)

    Mladenović Aleksandar R.

    2015-01-01

    Full Text Available This study describes the investigation of degradation products of donepezil (DP using stability indicating RP-HPLC method for determination of donepezil, which is a centrally acting reversible acetylcholinesterase inhibitor. In order to investigate the stability of drug and formed degradation products, a forced degradation study of drug sample and finished product under different forced degradation conditions has been conducted. Donepezil hydrochloride and donepezil tablets were subjected to stress degradation conditions recommended by International Conference on Harmonization (ICH. Donepezil hydrochloride solutions were subjected to acid and alkali hydrolysis, chemical oxidation and thermal degradation. Significant degradation was observed under alkali hydrolysis and oxidative degradation conditions. Additional degradation products were observed under the conditions of oxidative degradation. The degradation products observed during forced degradation studies were monitored using the high performance liquid chromatography (HPLC method developed. The parent method was modified in order to obtain LC-MS compatible method which was used to identify the degradation products from forced degradation samples using high resolution mass spectrometry. The mass spectrum provided the precise mass from which derived molecular formula of drug substance and degradation products formed and proved the specificity of the method unambiguously. [Projekat Ministarstva nauke Republike Srbije, br. 172013

  16. Microbial metabolomics with gas chromatography/mass spectrometry

    NARCIS (Netherlands)

    Koek, M.M.; Muilwijk, B.; Werf, M.J. van der; Hankemeier, T.

    2006-01-01

    An analytical method was set up suitable for the analysis of microbial metabolomes, consisting of an oximation and silylation derivatization reaction and subsequent analysis by gas chromatography coupled to mass spectrometry. Microbial matrixes contain many compounds that potentially interfere with

  17. Instrumental liquid chromatography: a practical manual on high-performance liquid chromatographic methods

    National Research Council Canada - National Science Library

    Parris, N. A

    1976-01-01

    Available texts on liquid chromatography have tended to emphasize the developments in the theoretical understanding of the technique and methodology or to list numerous applications, complete with experimental details...

  18. Gas-liquid contacting in mixing vessels

    International Nuclear Information System (INIS)

    Mann, R.

    1983-01-01

    This report by Dr. R. Mann of UMIST presents a critical survey of literature on the contacting of gases with liquids in stirred vessels. Research undertaken in the last fifteen years in analysed, and promising areas for future research are identified. The report deals with physical contacting, mass transfer between the gas and liquid phases and the utilisation of the stirred vessel as a gas-liquid reactor. Three sections are given on gas-liquid contacting: physical aspects; interphase mass transfer; and chemical reactions. It also discusses recent new approaches and includes a summary of conclusions, nomenclature and references

  19. Dual liquid and gas chromatograph system

    Science.gov (United States)

    Gay, D.D.

    A chromatographic system is described that utilizes one detection system for gas chromatographic and micro-liquid chromatographic determinations. The detection system is a direct-current, atmospheric-pressure, helium plasma emission spectrometer. The detector utilizes a nontransparent plasma source unit which contains the plasma region and two side-arms which receive effluents from the micro-liquid chromatograph and the gas chromatograph. The dual nature of this chromatographic system offers: (1) extreme flexibility in the samples to be examined; (2) extreme low sensitivity; (3) element selectivity; (4) long-term stability; (5) direct correlation of data from the liquid and gas samples; (6) simpler operation than with individual liquid and gas chromatographs, each with different detection systems; and (7) cheaper than a commercial liquid chromatograph and a gas chromatograph.

  20. Liquid Chromatography – Mass Spectrometry Method for the ...

    African Journals Online (AJOL)

    Purpose: To develop and validate a simple and selective high performance liquid chromatography photo diode array mass spectrometry (HPLC-PDA-MS/MS) method for simultaneous determination and confirmation of seven major active alkaloids (6-Hydroxy-ß-Carboline-1-carboxylic acid, ß-Carboline-1- carboxylic acid, ...

  1. An optimized gossypol high-performance liquid chromatography

    Indian Academy of Sciences (India)

    A comparative study on gossypol content of various genetic types of pigment glands of cotton varieties was conducted through an optimized high-performance liquid chromatography (HPLC) on a C18 column (4.6 mm × 250 mm, 5 m particle) with methanol–0.5% acetic acid aqueous solution, 90 : 10 (v/v), as mobile phase, ...

  2. Transfer of High Performance Liquid Chromatography with Diode ...

    African Journals Online (AJOL)

    2013-08-22

    Aug 22, 2013 ... 7. Transfer of High Performance Liquid Chromatography with Diode Array Detection. Method for Determination in Serum of Psychotropic drugs. Innocent Hahirwa1,2*, Corinne Charlier2, Charles Karangwa1, Raphaël Denooz2. 1Laboratory of Analysis of Foodstuffs, Drugs, Water and Toxics, University of ...

  3. Characterization of porous silicon integrated in liquid chromatography chips

    NARCIS (Netherlands)

    Tiggelaar, Roald M.; Verdoold, Vincent; Eghbali, H.; Desmet, G.; Gardeniers, Johannes G.E.

    2009-01-01

    Properties of porous silicon which are relevant for use of the material as a stationary phase in liquid chromatography chips, like porosity, pore size and specific surface area, were determined with high-resolution SEM and N2 adsorption–desorption isotherms. For the anodization conditions

  4. Characterisation of cholera toxin by liquid chromatography - Electrospray mass spectrometry

    NARCIS (Netherlands)

    Baar, B.L.M. van; Hulst, A.G.; Wils, E.R.J.

    1999-01-01

    Cholera toxin, one of the toxins that may be generated by various strains of the bacterium Vibrio cholerae, can be considered as a substance possibly used in biological warfare. The possibilities of characterising the toxin by liquid chromatography electrospray mass spectrometry (LC-ES-MS) were

  5. Coupling of column liquid chromatography and Fourier transform infrared spectrometry

    NARCIS (Netherlands)

    Somsen, G.W; Gooijer, C; Velthorst, N.H; Brinkman, U.A Th

    1998-01-01

    This paper provides an extensive overview of the literature on the coupling of column liquid chromatography (LC) and Fourier transform infrared spectrometry (FT-IR). Flow-cell-based FT-IR detection and early solvent-elimination interfaces for LC-FT-IR are discussed in brief. A comprehensive

  6. New Highly-Sensitive Ultra-Performance Liquid Chromatography ...

    African Journals Online (AJOL)

    Purpose: To develop and validate a simple, rapid, sensitive and specific ultraperformance liquid chromatography mass spectrometry method for the quantification of the angiotensin II receptor antagonist, telmisartan (TEL), in human plasma. Methods: After simple protein precipitation using acetonitrile and methanol, TEL and ...

  7. Quantification of Tea Flavonoids by High Performance Liquid Chromatography

    Science.gov (United States)

    Freeman, Jessica D.; Niemeyer, Emily D.

    2008-01-01

    We have developed a laboratory experiment that uses high performance liquid chromatography (HPLC) to quantify flavonoid levels in a variety of commercial teas. Specifically, this experiment analyzes a group of flavonoids known as catechins, plant-derived polyphenolic compounds commonly found in many foods and beverages, including green and black…

  8. Alternative solvents can make preparative liquid chromatography greener

    NARCIS (Netherlands)

    Shen, Y.; Chen, B.; Beek, van T.A.

    2015-01-01

    To make preparative Reversed-Phase High Performance Liquid Chromatography (RP-pHPLC) greener, alternative solvents were considered among others in terms of toxicity, cost, safety, workability, chromatographic selectivity and elution strength. The less toxic solvents ethanol, acetone and ethyl

  9. Determination of Caffeine in Beverages by High Performance Liquid Chromatography.

    Science.gov (United States)

    DiNunzio, James E.

    1985-01-01

    Describes the equipment, procedures, and results for the determination of caffeine in beverages by high performance liquid chromatography. The method is simple, fast, accurate, and, because sample preparation is minimal, it is well suited for use in a teaching laboratory. (JN)

  10. The high performance liquid chromatography (HPLC) analysis of ...

    African Journals Online (AJOL)

    A pilot study was done to determine the stability of the secondary compounds with high performance liquid chromatography (HPLC) after the samples were bleached with ultraviolet (UV) radiation and treated with activated charcoal. The chlorophyll a was successfully degraded with UV radiation in all the samples leaving a ...

  11. An optimized gossypol high-performance liquid chromatography ...

    Indian Academy of Sciences (India)

    A comparative study on gossypol content of various genetic types of pigment glands of cotton varieties was conducted through an optimized high-performance liquid chromatography (HPLC) on a C18 column (4.6 mm × 250 mm, 5 m particle) with methanol–0.5% acetic acid aqueous solution, 90 : 10 (v/v), as mobile phase, ...

  12. Studies on the analysis of benzo(a)pyrene and its metabolites in biological samples by using high performance liquid chromatography/fluorescence detection and gas chromatography/mass spectrometry

    International Nuclear Information System (INIS)

    Lee, Won; Hong, Jee Eun; Shin, Hye Seung; Pyo, Hee Soo; Kim, Yun Je

    2003-01-01

    An analytical method the determination of benzo(a)pyrene (BaP) and its hydroxylated metabolites, 1-hydroxybenzo(a)pyrene (1-OHBaP), 3-hydroxybenzo(a)pyrene (3-OHBaP), benzo(a)pyrene-4,5-dihydrodial(4,5-diolBaP) and benzo(a)pyrene-7,8-dihydrodiol (7,8-diolBaP), in rat urine and plasma has been developed by HPLC/FLD and GC/MS. The derivatization with alkyl iodide was employed to improve the resolution and the detection of two mono hydroxylated metabolites, 1-OHBaP and 3-OHBaP, in LC and GC. BaP and its four metabolites in spiked urine were successfully separated by gradient elution on reverse phase ODS C 18 column (4.6 mm I.D., 100 mm length, particle size 5μm) using a binary mixture of MeOH/H 2 O (85/15, v/v) as mobile phase after ethylation at 90 .deg. C for 10 min. The extraction recoveries of BaP and its metabolites in spiked samples with liquid-liquid extraction, which was better than solid phase extraction, were in the range of 90.3-101.6% in n-hexane for urine and 95.7-106.3% in acetone for plasma, respectively. The calibration curves has shown good linearity with the correlation coefficients (R 2 ) varying from 0.992 to 1.000 for urine and from 0.996 to 1.000 for plasma, respectively. The detection limits of all analytes were obtained in the range of 0.01-0.1 ng/mL for urine and 0.1-0.4ng/mL for plasma, respectively. The metabolites of BaP were excreted as mono hydroxy and dihydrodiol forms after intraperitoneal infection of 20 mg/kg of BaP to rats. The total amounts of BaP and four metabolites excreted in dosed rat urine were 3.79 ng over the 0 - 96 hr period from administration and the excretional recovery was less than 0.065% of the injection amounts of BaP. The proposed method was successfully applied to the determination of BaP and its hydroxylated metabolites in rat urine and plasma for the pharmacokinetic studies

  13. FSU's natural gas liquids business needs investment

    International Nuclear Information System (INIS)

    Plotnikov, V.S.; Berman, M.; Angerinos, G.F.

    1995-01-01

    Production of natural gas liquids has fallen seriously behind its potential in the former Soviet Union (FSU). Restoration of the gas liquids business thus represents a rich investment opportunity. Capital, however, must come from international sources, which remain uncertain about the FSU's legal, commercial, and political systems. If these hurdles can be overcome, FSU output of liquid petroleum gas alone might double between 1990 and 2010. In the FSU, LPG is produced from associated and nonassociated natural gas, condensate, and refinery streams. It also comes from what is known in the FSU as ShFLU--a mixture of propane, butane, pentane, and hexane produced at gas processing plants in Western Siberia and fractionated elsewhere. The paper reviews FSU production of gas liquids focusing on West Siberia, gives a production outlook, and describes LPG use and business development

  14. Towards early detection of the hydrolytic degradation of poly(bisphenol A)carbonate by hyphenated liquid chromatography and comprehensive two-dimensional liquid chromatography

    NARCIS (Netherlands)

    Coulier, L.; Kaal, E.R.; Hankemeier, Th.

    2006-01-01

    The hydrolytic degradation of poly(bisphenol A)carbonate (PC) has been characterized by various liquid chromatography techniques. Size exclusion chromatography (SEC) showed a significant decrease in molecular mass as a result of hydrolytic degradation, while 'liquid chromatography at critical

  15. Identification and quantification of (polymeric) hindered-amine light stabilizers in polymers using pyrolysis-gas chromatography-mass spectrometry and liquid chromatography-ultraviolet absorbance detection-evaporative light scattering detection.

    Science.gov (United States)

    Coulier, L; Kaal, E R; Tienstra, M; Hankemeier, Th

    2005-01-14

    Direct analysis of polymers containing polymeric hindered amine light stabilizers (HALS) by using pyrolysis coupled to GC-MS is applied successfully for fast and straightforward identification of these HALS additives. Each of the HALS additives shows different pyrolysis gas chromatograms containing characteristic pyrolysis products. As a result, HALS additives with very similar chemical structures, e.g. Chimassorb 944 and Chimassorb 2020, can be distinguished. A HPLC method with both ultraviolet (UV) and evaporative light scattering detection (ELSD) is developed to quantify the various HALS additives in extracts of polymers. The critical factor of the HPLC method is the use of a basic amine, like n-hexylamine, as a solvent additive to facilitate the elution of HALS additives. The various HALS additives can be distinguished according to retention time and peak shape and by using different detection methods. The suitability of the developed methods is demonstrated by the analytical performance of the HPLC method and the identification and determination of the actual content of HALS additives in polyolefines using pyrolysis GC-MS and HPLC. The HPLC method can also be used for the determination of the specific migration of HALS additives from food contact materials.

  16. Stabilized ultrathin liquid membranes for gas separations

    International Nuclear Information System (INIS)

    Deetz, D.W.

    1987-01-01

    Although immobilized liquid membranes have the desirable properties of high selectivity and permeability, their practical application to gas phase separations is hindered because of the instability of the liquid phase and the relative thickness of current membranes. The problem of liquid instability, which is due to both liquid volatilization and flooding, can be reduced, or eliminated, by immobilizing the liquid phase in pores small enough to significantly reduce the molar free energy of the solution via the Kelvin effect. The obstacle of membrane thickness can be overcome by selectively immobilizing the liquid phase into the skin of a porous asymmetric membranes

  17. Optimizing heterosurface adsorbent synthesis for liquid chromatography

    Science.gov (United States)

    Bogoslovskii, S. Yu.; Serdan, A. A.

    2016-03-01

    The structural and geometric parameters of a silica matrix (SM) for the synthesis of heterosurface adsorbents (HAs) are optimized. Modification is performed by shielding the external surfaces of alkyl-modified silica (AS) using human serum albumin and its subsequent crosslinking. The structural and geometric characteristics of the SM, AS, and HA are measured via low-temperature nitrogen adsorption. It is found that the structural characteristics of AS pores with diameters D 9 nm reduces significantly due to adsorption of albumin. It is concluded that silica gel with a maximum pore size distribution close to 5 nm and a minimal proportion of pores with D > 9 nm is optimal for HA synthesis; this allows us to achieve the greatest similarity between the chromatographic retention parameters for HA and AS. The suitability of the synthesized adsorbents for analyzing drugs in biological fluids through direct sample injection is confirmed by chromatography. It was found that the percentage of the protein fraction detected at the outlet of the chromatographic column is 98%.

  18. Selective gas absorption by ionic liquids

    DEFF Research Database (Denmark)

    Shunmugavel, Saravanamurugan; Kegnæs, Søren; Due-Hansen, Johannes

    2010-01-01

    processes for flue gas cleaning. The results show that CO 2, NO and SO2 can be reversible and selective absorbed using different ILs and that Supported Ionic Liquid-Phase (SILP) absorbers are promising materials for industrial flue gas cleaning. Absorption/desorption dynamics can be tuned by temperatures......Reversible absorption performance for the flue gas components CO 2, NO and SO2 has been tested for several different ionic liquids (ILs) at different temperatures and flue gas compositions. Furthermore, different porous, high surface area carriers have been applied as supports for the ionic liquids...... to obtain Supported Ionic Liquid-Phase (SILP) absorber materials. The use of solid SILP absorbers with selected ILs were found to significantly improve the absorption capacity and sorption dynamics at low flue gas concentration, thus making the applicability of ILs viable in technical, continuous flow...

  19. Fast temperature programming in gas chromatography using resistive heating

    NARCIS (Netherlands)

    Dallüge, J.; Ou-Aissa, R.; Vreuls, J.J.; Brinkman, U.A.T.; Veraart, J.R.

    1999-01-01

    The features of a resistive-heated capillary column for fast temperature-programmed gas chromatography (GC) have been evaluated. Experiments were carried out using a commercial available EZ Flash GC, an assembly which can be used to upgrade existing gas chromatographs. The capillary column is placed

  20. Early stages in the history of gas chromatography.

    Science.gov (United States)

    Kolomnikov, Ivan G; Efremov, Alexander M; Tikhomirova, Tatyana I; Sorokina, Nadezhda M; Zolotov, Yury A

    2018-02-16

    The creation of gas chromatography is traditionally associated with the names of Nobel Prize winner Archer Martin and his colleagues Richard Synge and Anthony James. However, sometimes references to their predecessors can be found. An investigation conducted by the authors of this article not only confirmed the reliability of these references; but in fact led to the conclusion that by 1952, which is commonly believed to be the year when gas chromatography was born, many research papers had already been devoted to this method, mainly, in its gas-solid version. These papers are considered in this article. Copyright © 2018. Published by Elsevier B.V.

  1. Application of genetic algorithms for parameter estimation in liquid chromatography

    International Nuclear Information System (INIS)

    Hernandez Torres, Reynier; Irizar Mesa, Mirtha; Tavares Camara, Leoncio Diogenes

    2012-01-01

    In chromatography, complex inverse problems related to the parameters estimation and process optimization are presented. Metaheuristics methods are known as general purpose approximated algorithms which seek and hopefully find good solutions at a reasonable computational cost. These methods are iterative process to perform a robust search of a solution space. Genetic algorithms are optimization techniques based on the principles of genetics and natural selection. They have demonstrated very good performance as global optimizers in many types of applications, including inverse problems. In this work, the effectiveness of genetic algorithms is investigated to estimate parameters in liquid chromatography

  2. An inverse gas chromatographic methodology for studying gas-liquid mass transfer.

    Science.gov (United States)

    Paloglou, A; Martakidis, K; Gavril, D

    2017-01-13

    A novel methodology of reversed flow inverse gas chromatography (RF-IGC) is presented. It permits the simultaneous determination of mass transfer coefficients across the gas liquid interface as well as the respective solubility parameters and thermodynamic functions of dissolution of gases into liquids. The standard deviation of the experimentally determined parameters is estimated for first time, which combined with the successful comparison of the values of the present parameters with other literature ones ascertain the reliability of the methodology. Another novelty of the present work is that the chromatographic sampling of the physicochemical phenomena is done without performing the usual flow reversals procedure. Vinyl chloride monomer's (VCM) interaction with various composition liquid foods: orange juice, milk and olive oil was used as model system. The present transfer rates are controlled by the gas film at lower temperatures, but at higher temperatures the resistances in both films tend to become equal. The found liquid diffusivity values express the total mass transfer from the gas phase into the liquid's bulk and they decrease with rising temperature, as the solubilities of gases in liquids do. Solubility, expressed by Henry's law constant and the mean values of interfacial thickness are of the same order of magnitude to literature ones. From the thermodynamic point of view, VCM dissolution in all liquids is accompanied by significant heat release and it is a slightly non-spontaneous process, near equilibrium, while the entropy change values are negative. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. 21 CFR 862.2260 - High pressure liquid chromatography system for clinical use.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false High pressure liquid chromatography system for... Clinical Laboratory Instruments § 862.2260 High pressure liquid chromatography system for clinical use. (a) Identification. A high pressure liquid chromatography system for clinical use is a device intended to separate...

  4. Quantitative analysis of pharmacokinetic study samples by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS).

    Science.gov (United States)

    Mück, W

    1999-09-01

    The basis of all pharmacokinetic evaluations are powerful assays to quantify drugs and/or metabolites in biological matrices using modern sensitive instrumental analytical techniques, such as capillary gas chromatography and high-performance liquid chromatography (HPLC). Being both specific and universal, mass spectrometry (MS) is an ideal chromatographic detector. Due to recent exciting achievements in the interfacing of liquid chromatography (LC) and MS, LC-MS, like the successfully preceding hyphenated technique gas chromatography-mass spectrometry (GC-MS), has now become a valuable technique in the analyst's toolbox. The key features of LC-MS are explained and four examples demonstrating its potential for highly specific and sensitive routine drug assays with the option of high sample throughput in pharmacokinetic investigations are presented.

  5. SEAPORT LIQUID NATURAL GAS STUDY

    Energy Technology Data Exchange (ETDEWEB)

    COOK,Z.

    1999-02-01

    The Seaport Liquid Natural Gas Study has attempted to evaluate the potential for using LNG in a variety of heavy-duty vehicle and equipment applications at the Ports of Los Angeles and Oakland. Specifically, this analysis has focused on the handling and transport of containerized cargo to, from and within these two facilities. In terms of containerized cargo throughput, Los Angeles and Oakland are the second and sixth busiest ports in the US, respectively, and together handle nearly 4.5 million TEUs per year. At present, the landside handling and transportation of containerized cargo is heavily dependent on diesel-powered, heavy-duty vehicles and equipment, the utilization of which contributes significantly to the overall emissions impact of port-related activities. Emissions from diesel units have been the subject of increasing scrutiny and regulatory action, particularly in California. In the past two years alone, particulate matter from diesel exhaust has been listed as a toxic air contaminant by CAM, and major lawsuits have been filed against several of California's largest supermarket chains, alleging violation of Proposition 65 statutes in connection with diesel emissions from their distribution facilities. CARE3 has also indicated that it may take further regulatory action relating to the TAC listing. In spite of these developments and the very large diesel emissions associated with port operations, there has been little AFV penetration in these applications. Nearly all port operators interviewed by CALSTART expressed an awareness of the issues surrounding diesel use; however, none appeared to be taking proactive steps to address them. Furthermore, while a less controversial issue than emissions, the dominance of diesel fuel use in heavy-duty vehicles contributes to a continued reliance on imported fuels. The increasing concern regarding diesel use, and the concurrent lack of alternative fuel use and vigorous emissions reduction activity at the Ports

  6. Ionic Liquid-Liquid Chromatography: A New General Purpose Separation Methodology.

    Science.gov (United States)

    Brown, Leslie; Earle, Martyn J; Gîlea, Manuela A; Plechkova, Natalia V; Seddon, Kenneth R

    2017-08-10

    Ionic liquids can form biphasic solvent systems with many organic solvents and water, and these solvent systems can be used in liquid-liquid separations and countercurrent chromatography. The wide range of ionic liquids that can by synthesised, with specifically tailored properties, represents a new philosophy for the separation of organic, inorganic and bio-based materials. A customised countercurrent chromatograph has been designed and constructed specifically to allow the more viscous character of ionic liquid-based solvent systems to be used in a wide variety of separations (including transition metal salts, arenes, alkenes, alkanes, bio-oils and sugars).

  7. Changes in the basic experimental parameters of capillary gas chromatography in the 20th century.

    Science.gov (United States)

    Berezkin, V G; Viktorova, E N

    2003-01-24

    Studies of qualitative changes in capillary gas chromatography are of significant practical and scientific interest. This paper analyzes the evolution of the most important experimental chromatographic parameters over the last three decades and is based on the use of a new approach to scientometrical research that is referred to as applied scientometry. One essential feature of this approach is that it looks at the entire contents of each paper rather than only taking account its title, abstract. and references (as is typical for conventional scientometry). In this paper, we monitor how the most important chromatographic parameters, such as column length and diameter, layer thickness, stationary liquid phases, separation temperature mode. etc., have been evolving over the period 1970-2000. We used data from the following journals: Chromatographia, Journal of Chromatography, and Journal of High Resolution Chromatography and Chromatography Communications.

  8. Thin-layer chromatography - liquid chromatography, an ideal supplement demonstrated by the separation of lanthanoids

    International Nuclear Information System (INIS)

    Specker, H.; Hufnagel, A.

    1984-01-01

    All lanthanoids have been separated by thin-layer chromatography (TLC) with short retention times by using a mixture of ether/tetrahydrofurane (THF)/bis-(2-ethylhexyl)-phosphate (HDEHP)/nitric acid. The eluent was empirically tested by synergistic effects. The results have been transferred to high-performance liquid chromatography /HPLC). It was possible to use the same eluent in TLC and HPLC both for the analytical separation of all lanthanoids and for the separation of fission products. The experimental experience gained in HPLC could be applied to the pre-concentration of isotopes in TLC. Both methods excellently supplemented each other in the separation of lanthanoids. (orig.) [de

  9. Undiscovered Natural Gas Liquids Colorado Plateau

    Data.gov (United States)

    Department of the Interior — This dataset is based on U.S. Geological Survey (USGS) resource assessments for “undiscovered” natural gas liquid resources, which are resources that have not yet...

  10. Determination of polycyclic aromatic hydrocarbons (PAHs) from organic aerosols using hollow fiber micro-porous membrane liquid-liquid extraction (HF-MMLLE) followed by gas chromatography-mass spectrometry analysis.

    Science.gov (United States)

    Hyder, Murtaza; Aguilar, Lidia Luque; Genberg, Johan; Sandahl, Margareta; Wesén, Clas; Jönsson, Jan Åke

    2011-08-15

    A method for determination of polycyclic aromatic hydrocarbons (PAHs) from aerosols was developed. Instead of conventionally used non-polar or slightly polar phenylmethylpolysiloxane column a highly polar, highly substituted, cyanopropyl column (VF-23 MS) was used for separation of PAHs. Based on hollow fiber micro-porous membrane liquid-liquid extraction (HF-MMLLE) a method was developed for sample clean up and pretreatment. An enrichment factor of 617-1022 was obtained with extraction efficiency 10.2-18.9% for different PAHs analyzed in this study. The optimized method was successfully applied to aerosol samples and limits of detection between 1.2 pg m(-3) and 180 pg m(-3) was obtained. Almost all PAHs were found in most of the aerosol samples. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. Applications of Ultra High Performance Liquid Chromatography for Natural Products

    International Nuclear Information System (INIS)

    Rosniza Razali; Hazlina Ahmad Hassali; Azfar Hanif Abd Aziz; Daryl Jesus Arapoc

    2015-01-01

    Ultra high performance liquid chromatography (UHPLC) is a very powerful and versatile chromatographic technique for the separation of natural products in complex matrices, such as crude extracts for quantification or general profiling. The method is widespread and has been adapted to the analysis of a broad range of natural products generally without the need for complex sample preparation. The present paper overviews regarding the UHPLC and its applications for natural products. (author)

  12. High performance liquid chromatography in studies of radiolabeled antibodies

    International Nuclear Information System (INIS)

    Hnatowich, D.J.

    1986-01-01

    High performance liquid chromatography (HPLC) as applied to the separation of antibodies displays the same advantages as in its other applications, namely good resolution accompanied by fast analysis. It is therefore not surprising that many HPLC columns designed for use with antibodies and other proteins are now available commercially. The properties of proteins which provide the separation are size, hydrophobicity, charge and affinity. The features of each are discussed. (author)

  13. Determination of oxyfluorfen herbicide and oxyfluorfen amine residues in garbanzo beans by liquid chromatography.

    Science.gov (United States)

    Zhou, M; Miles, C J

    1991-01-01

    Oxyfluorfen and oxyfluorfen amine were determined by liquid chromatography (LC) with ultraviolet (UV) and photoconductivity detection (PCD). A simple extraction procedure acceptably recovered both analytes from garbanzo beans over a wide range of fortifications (0.05 to 20 ppm) (83 +/- 4 for oxyfluorfen; 85 +/- 4 for oxyfluorfen amine). Percent recoveries decreased slightly as the fortification level decreased. Both analytes could be determined simultaneously at a concentration greater than 0.2 ppm in garbanzo beans. Detection limits were 3 ng for oxyfluorfen and 100 ng for oxyfluorfen amine using LC/UV, and 12 ng for both oxyfluorfen and oxyfluorfen amine with LC/PCD. Different knitted reaction coils and photoreactors were evaluated. Photoproduct yields and identification were determined by ion chromatography. The LC/PCD method measures oxyfluorfen and oxyfluorfen amine separately and has a shorter analysis time, while the standard method using gas chromatography measures total residues and is more sensitive.

  14. Economics of gas to liquids manufacture

    International Nuclear Information System (INIS)

    Gradassi, M.J.

    1998-01-01

    The last year has seen a great deal in the literature about the rebirth of gas to liquids processes, most notably, Fischer Tropsch processes. This renewed interest has been brought about by a technology that is said to have been so improved that it is now a commercially attractive option for natural gas monetization. No one single reason can be cited for this positive economic change. Rather, it is the result of several technological improvements that together have cut the capital cost of Fischer-Tropsch gas to liquids projects in half. Among these technological improvements are lower cost syngas preparation and lower cost gas to liquids reactors. This paper examines the economics of Fischer-Tropsch gas to liquids manufacture, using recent literature articles to develop process capital costs, operating expenses, liquid product value parameters, and other economic factors, to paint a general picture of the technology's current economic status. While manufacturing economics are reviewed, the answer to the question of gas to liquids project profitability is left to the individual investor whose economic thresholds must, in the final analysis, be met. 15 refs

  15. Method for analysis of heavy sulphur compounds using gas chromatography with flame photometric detection

    OpenAIRE

    Moreira, N.; Pinho, P. Guedes de; Vasconcelos, I.

    2004-01-01

    A method for analysis of heavy sulphur compounds in wines, based on gas chromatography (GC) with flame photometric detection, is reported. Wine samples preparation includes a dichloromethane liquid–liquid extraction followed by concentration under a nitrogen atmosphere. The extracted fraction was also analysed by GC–mass spectrometry. The method enables high recovery of sulphur compounds in wine and satisfies the requirements of repeatability and sensitivity. Applications of the meth...

  16. Gas-to-liquid technologies: India's perspective

    International Nuclear Information System (INIS)

    Reddy Keshav, Tirupati; Basu, S.

    2007-01-01

    Gas-to-liquid (GTL) technologies are capable of converting gas to clean, useful liquid hydrocarbons and thus suitable for addressing problems of remote gas utilization, increase in crude oil price, depletion of fossil fuel and environmental pollution. The Indian state of Tripura is considered to be the richest province with 26 billion cubic meters of gas reserves. Neighboring country Myanmar has huge gas reserves but these reserves remain unutilized mainly because of land-locked situation. GTL is a well developed and proven technology and it is an important option for moving natural gas to the market place. GTL options include not only the well-known production of Fischer-Tropsch synthesis liquids but also the production of oxygen containing fuels, fuel additives and chemicals, such as methanol and DME. An alternative, promising option to convert surplus gas is the direct route of methane conversion, which is more energy efficient than the indirect route since it bypasses the energy intensive endothermic steam reforming step of syngas formation. On-site conversion to liquid products of commercial importance using direct route would make transportation of these natural deposits much more economical and practical. In this paper an attempt has been made to review recent developments in syngas technologies, direct routes of methane conversion into useful liquids, and status of both existing and future developments in GTL industry around the world. Finally challenges in GTL technology are discussed. (author)

  17. Carbon nanotubes-A resin for electrochemically modulated liquid chromatography.

    Science.gov (United States)

    Brammen, Markus; Fraga-García, Paula; Berensmeier, Sonja

    2017-03-01

    Electrochemically modulated liquid chromatography is a special form of ion exchange chromatography in which the separation process is controlled by applying an electric potential to the stationary phase. This form of chromatography has so far only been applied in research studies. The present study shows that multiwalled carbon nanotubes are an effective resin material for an electrochemically modulated chromatography process. The experiments are carried out in a newly designed column that enables the packing of nanomaterials. We investigate the influence of the applied potential on the retention and elution of maleic acid, determine the dynamic binding capacity, and calculate the utilization degree of the electrical charge in the adsorption process. Moreover, the stability of the resin and the membrane over more than 200 working hours are presented. In addition to the stability, their sturdiness and inexpensive price are important qualities that make multiwalled carbon nanotubes interesting for application as the stationary phase in an electrochemically driven process. The investigated chromatography technique represents a promising separation process for future applications as a preparative step in biotechnology as well as other life science fields. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Gas chromatography-mass spectrometry determination of polycyclic aromatic hydrocarbons in baby food using QuEChERS combined with low-density solvent dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Petrarca, Mateus Henrique; Godoy, Helena Teixeira

    2018-08-15

    A sensitive GC-MS method is reported for the determination of twelve polycyclic aromatic hydrocarbons (PAHs) in baby food. The sample preparation involves QuEChERS extraction combined with low-density solvent dispersive liquid-liquid microextraction (LDS-DLLME) and ultra-low temperature (-80 °C). Plackett-Burman screening design was employed to identify the main sample preparation variables that affect the extraction efficiency, such as the volume of toluene used in LDS-DLLME. The suitability of proposed method was verified by analytical selectivity, linearity in solvent and matrix-matched calibration curves and adequate recoveries (72-112%) and precision (RSD values ≤11%), under repeatability and within-laboratory reproducibility conditions. High analytical sensitivity was achieved for the monitoring of PAHs at the strict limit of 1 µg kg -1 fixed by the European Commission for baby foods. The validated method was applied to thirty-two commercial baby food samples, and the investigated PAHs were not detected in any sample. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Polyol-enhanced dispersive liquid-liquid microextraction coupled with gas chromatography and nitrogen phosphorous detection for the determination of organophosphorus pesticides from aqueous samples, fruit juices, and vegetables.

    Science.gov (United States)

    Farajzadeh, Mir Ali; Afshar Mogaddam, Mohammad Reza; Alizadeh Nabil, Ali Akbar

    2015-12-01

    Polyol-enhanced dispersive liquid-liquid microextraction has been proposed for the extraction and preconcentration of some organophosphorus pesticides from different samples. In the present study, a high volume of an aqueous phase containing a polyol (sorbitol) is prepared and then a disperser solvent along with an extraction solvent is rapidly injected into it. Sorbitol showed the best results and it was more effective on the extraction recoveries of the analytes than inorganic salts such as sodium chloride, potassium chloride, and sodium sulfate. Under the optimum extraction conditions, the method showed low limits of detection and quantification within the ranges of 12-56 and 44-162 pg/mL, respectively. Enrichment factors and extraction recoveries were in the ranges of 2799-3033 and 84-92%, respectively. The method precision was evaluated at a concentration of 10 ng/mL of each analyte, and relative standard deviations were found to be less than 5.9% for intraday (n = 6) and less than 7.8% for interday (n = 4). Finally, some aqueous samples were successfully analyzed using the proposed method and four analytes (diazinon, dimethoate, chlorpyrifos, and phosalone) were determined, some of them at ng/mL level. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Gas chromatography/matrix-isolation apparatus

    Science.gov (United States)

    Reedy, Gerald T.

    1986-01-01

    A gas-sample collection device provides matrix isolation of individual gas bands from a gas chromatographic separation and for the spectroscopic analysis of the individual sample bands. The device includes a vacuum chamber containing a rotatably supported, specular carousel having at least one reflecting surface for holding a sample deposited thereon. A gas inlet is provided for depositing a mixture of sample and matrix material on the reflecting surface which is maintained at a sufficiently low temperature to cause solidification. A first parabolic mirror directs an incident beam of electromagnetic radiation, such as in the infrared (IR) spectrum, from a source onto the sample/matrix mixture while a second parabolic mirror directs a second beam of electromagnetic radiation reflected by the specular surface to an IR spectrometer for determining the absorption spectra of the sample material deposited on the reflecting surface. The pair of off-axis parabolic mirrors having a common focal point are positioned outside of the vacuum chamber and may be displaced in combination for improved beam positioning and alignment. The carousel is provided with an aperture for each reflecting surface to facilitate accurate positioning of the incident beam relative to the gas-samples under analysis. Improved gas-sample deposition is insured by the use of a long focal length stereomicroscope positioned outside of the vacuum chamber for monitoring sample formation through a window, while the sample collector is positioned outside of the zone bounded by the incident and reflected electromagnetic beams for improved sample access and monitoring.

  1. Fast analysis of phthalates in freeze-dried baby foods by ultrasound-vortex-assisted liquid-liquid microextraction coupled with gas chromatography-ion trap/mass spectrometry.

    Science.gov (United States)

    Russo, Mario Vincenzo; Avino, Pasquale; Notardonato, Ivan

    2016-11-25

    This paper is focused on the determination of phthalates (PAEs), compounds "plausibly" endocrine disruptors, in baby food products by means of a method based on ultrasound-vortex-assisted liquid-liquid microextraction coupled with GC-IT/MS (UVALLME-GC-IT/MS). Particularly, the whole procedure allows the determination of six phthalates such as DMP, DEP, DBP, iBcEP, BBP and DEHP. After dissolution of 0.1g product sample and addition of anthracene as Internal Standard, 250μL of n-heptane are used as extraction solvent. The solution, held for 5min on the vortex mixer and for 6min in an ultrasonic bath at 100W for favoring the solvent dispersion and consequently the analyte extraction, is centrifuged at 4000rpm for 30min. About 100μL of heptane are recovered and 1μL is injected into the GC-IT/MS. All the analytical parameters investigated are deeply discussed: under the best conditions, the percentage recoveries range between 96.2 and 109.2% with an RSD ≤10.5% whereas the Limit of Detections (LODs) and the Limit of Quantifications (LOQs) are below 11 and 20ngg -1 , respectively, for all the PAEs except for iBcEP (23 and 43ngg -1 , respectively). The linear dynamic range of this procedure is between 10 and 5000ngg -1 with R 2 ≥0.92. The method has been applied to real commercial freeze-dried samples (chicken and turkey meats) available on the Italian pharmaceutical market: three PAEs were preliminary identified, i.e. DEP (14ngg -1 ), DBP (11ngg -1 ) and DEHP (64ngg -1 ). Copyright © 2016. Published by Elsevier B.V.

  2. Protein separations using enhanced-fluidity liquid chromatography.

    Science.gov (United States)

    Bennett, Raffeal; Olesik, Susan V

    2017-11-10

    Enhanced-fluidity liquid chromatography (EFLC) methods using methanol/H 2 O/CO 2 and hydrophilic interaction liquid chromatography (HILIC) were explored for the separation of proteins and peptides. EFLC is a separation mode that uses a mobile phase made of conventional solvents combined with liquid carbon dioxide (CO 2 ) in subcritical conditions. The addition of liquid CO 2 enhances diffusivity and decreases viscosity while maintaining mixture polarity, which typically results in reduced time of analysis. TFA additive and elevated temperature were leveraged as key factors in the separation of a 13-analyte intact protein mixture in under 5min. Under these conditions EFLC showed modest improvement in terms of peak asymmetry and analysis time over the competing ACN/H 2 O separation. Protein analytes detected by electrospray ionization - quadrupole time of flight, were shown to be unaffected by the addition of CO 2 in the mobile phase. Herein, the feasibility of separating hydrophilic proteins up to 80kDa (with transferrin) is demonstrated for CO 2 -containing mobile phases. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Unstable well behaviour in gas well liquid loading

    NARCIS (Netherlands)

    Belfroid, S.P.C.; Wijhe, A. van

    2017-01-01

    Liquid loading is the mechanism that is associated with increased liquid hold-up and liquid back flow at lower gas flow rates in gas production wells. In laboratory, most liquid loading experiments are performed at fixed gas and liquid rates (mass flow controlled). In the field, the well behavior is

  4. Gas chromatography/matrix-isolation apparatus

    Science.gov (United States)

    Reedy, G.T.

    1986-06-10

    A gas-sample collection device provides matrix isolation of individual gas bands from a gas chromatographic separation and for the spectroscopic analysis of the individual sample bands. The device includes a vacuum chamber containing a rotatably supported, specular carousel having at least one reflecting surface for holding a sample deposited thereon. A gas inlet is provided for depositing a mixture of sample and matrix material on the reflecting surface which is maintained at a sufficiently low temperature to cause solidification. A first parabolic mirror directs an incident beam of electromagnetic radiation, such as in the infrared (IR) spectrum, from a source onto the sample/matrix mixture while a second parabolic mirror directs a second beam of electromagnetic radiation reflected by the specular surface to an IR spectrometer for determining the absorption spectra of the sample material deposited on the reflecting surface. The pair of off-axis parabolic mirrors having a common focal point are positioned outside of the vacuum chamber and may be displaced in combination for improved beam positioning and alignment. The carousel is provided with an aperture for each reflecting surface to facilitate accurate positioning of the incident beam relative to the gas-samples under analysis. Improved gas-sample deposition is insured by the use of a long focal length stereomicroscope positioned outside of the vacuum chamber for monitoring sample formation through a window, while the sample collector is positioned outside of the zone bounded by the incident and reflected electromagnetic beams for improved sample access and monitoring. 10 figs.

  5. Comprehensive two-dimensional liquid chromatography and hyphenated liquid chromatography to study the degradation of poly(bisphenol A)carbonate

    NARCIS (Netherlands)

    Coulier, L.; Kaal, E.R.; Hankemeier, T.

    2005-01-01

    Size exclusion chromatography (SEC), gradient polymer elution chromatography (GPEC) and liquid chromatography at critical conditions (LC-CC) have been developed and applied to observe chemical changes in poly(bisphenol A)carbonate (PC) due to hydrolytic degradation. Especially LC-CC appeared to be

  6. Comparative characteristic of concentration units relating to reference materials for gas chromatography analysis of hydrocarbon samples

    Directory of Open Access Journals (Sweden)

    S. A. Arystanbekova

    2014-01-01

    Full Text Available Application of a method of absolute calibration relating to gas chromatography analysis of liquid hydrocarbon samples is considered. It is shown for this task that both from theoretical, and practical points of view the optimum concentration unit is mass (not molar fraction. Information on average molar mass of the analyzed sample is necessary for the determination of analytes in liquid hydrocarbon samples in terms of mole fraction. Meanwhile, the normative documents of rather high rank (ASTM, ISO, GOST, GOST R concerning methods of the determination of average molar weight of samples of such a kind are absent.

  7. Csaba Horváth and preparative liquid chromatography.

    Science.gov (United States)

    Guiochon, Georges

    2005-06-24

    Few chromatographers have been interested in furthering preparative liquid chromatography. The pioneers, Tswett, Kuhn and Lederer, A.J.P. Martin, Tiselius, isolated fractions but as an intermediate step in the analysis of their samples. The progress in electronics and sensors, and in their miniaturization has lead to the paradoxical situation that the analysts never see the transient pure fractions that their detector quantitates. Yet, over the last 25 years, preparative liquid chromatography has become an important industrial process for the separation, the extraction, and/or the purification of many pharmaceuticals or pharmaceutical intermediates, including pure enantiomers, purified peptides and proteins, compounds that are manufactured at the relatively large industrial scale of a few kilograms to several hundred tons per year. This development that has strongly affected the modem pharmaceutical industry is mainly due to the pioneering work of Csaba Horváth. His work in preparative HPLC was critical at both the practical and the theoretical levels. He was the first scientist in modem times to pay serious attention to the relationships between the curvature of the equilibrium isotherms, the competitive nature of nonlinear isotherms, and the chromatographic band profiles of complex mixtures. The thermodynamics of multi-component phase equilibria and mass transfer kinetics in chromatography attracted his interest and were the focus of ground-breaking contributions. He investigated displacement chromatography, an old method invented by Tiselius that Csaba was first to implement in HPLC. This choice was explained by the essential characteristic of displacement chromatography, in that it delivers fractions that can be far more concentrated than the feed. Remarkably, once the basics of nonlinear chromatography had been mastered in his group, most of the applications that were studied by his coworkers dealt with peptides of various sizes and with proteins. Thus, all

  8. A high-throughput method for liquid chromatography-tandem mass spectrometry determination of plasma alkylresorcinols, biomarkers of whole grain wheat and rye intake

    DEFF Research Database (Denmark)

    Ross, Alastair B; Svelander, Cecilia; Savolainen, Otto I

    2016-01-01

    supported extraction methods for extracting alkylresorcinols from plasma and improved a normal-phase liquid chromatography coupled to a tandem mass spectrometer method to reduce sample analysis time. The method was validated and compared with gas chromatography-mass spectrometry analysis. Sample preparation...

  9. Analysis of sulphur compounds in underground reservoirs of natural gas and town gas by gas chromatography and mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Triska, J.; Kuras, M.; Zachar, P.; Vodicka, L. (Institute of Chemical Technology, Prague (Czechoslovakia). Lab. of Synthetic Fuels)

    1990-09-01

    This paper deals with mass spectrometry and gas chromatography of the sulphur compounds in waste waters from the natural gas underground reservoirs, in extracts of activated charcoal used for purification of town gas, and in the oils from compressors of natural gas. (orig.).

  10. High resolution gas chromatography in dedicated petrochemical and environmental analysis

    International Nuclear Information System (INIS)

    Nijs, R. De

    1990-01-01

    Turn key systems dedicated and designed for a special application in petrochemical as well as environmental analysis are used already for many years. However, the use of high resolution gas chromatography columns in this type of equipment is only performed recently. In petrochemistry, examples of this type of systems are analyzers for light hydrocarbons, inerts and oxygenates in petrochemical streams and natural gas. In environmental monitoring analyzers for hydrocarbons and halogenated hydrocarbons in air or waste water and surface water are of importance. The use of capillary gas chromatography columns in this kind of application is resulting, when compared with packed columns, in improved separation power, a higher speed of analysis and in most cases a lower detection limit. Because of the high separation power of capillary columns, when compared with packed columns, the amount of columns needed to obtain a certain separation is less and so the analysis is simplified, becoming more reliable. For environmental analysis the use of high resolution columns in combination with thermal desorption could trap techniques in the analysis of volatile organic compound (VOC) in air results in information on ppb or even ppt level pollution of hydrocarbon and halogenated hydrocarbons. For the analysis of VOC's in water purge and trap techniques are used in combination with high resolution gas chromatography. Applications and results obtained with above mentioned equipment will be discussed. Special attention will be given to the incorporation of high resolution chromatography in this type of equipment

  11. Analysis of essential oils by gas chromatography and mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Masada, Y.

    1976-01-01

    The book is in two parts: first part Essential Oil includes compositae; labiatae; verbenaceae; oleaceae; umbelliferae; myrtaceae; euphorbiaceae; rutaceae; geraniaceae; rosaceae; lauraceae; myristicaceae; anonaceae; santalaceae; moraceae; piperaceae; zingiberaceae; araceae; gramineae; and cupressaceae written in English and Japanese. Part two includes essential oil; gas chromatography, and mass spectrometry written in Japanese. (DP)

  12. Enthalpy of Vaporization by Gas Chromatography: A Physical Chemistry Experiment

    Science.gov (United States)

    Ellison, Herbert R.

    2005-01-01

    An experiment is conducted to measure the enthalpy of vaporization of volatile compounds like methylene chloride, carbon tetrachloride, and others by using gas chromatography. This physical property was measured using a very tiny quantity of sample revealing that it is possible to measure the enthalpies of two or more compounds at the same time.

  13. Gas chromatography mass spectrometry : key technology in metabolomics

    NARCIS (Netherlands)

    Koek, Maud Marijtje

    2009-01-01

    Metabolomics involves the unbiased quantitative and qualitative analysis of the complete set of metabolites present in cells, body fluids and tissues. Gas chromatography coupled to mass spectrometry (GC-MS) is very suitable for metabolomics analysis, as it combines high separation power with

  14. Gas Chromatography Mass Spectrometry of Quassia undulata Seed ...

    African Journals Online (AJOL)

    Prof. Ogunji

    Key words: Quassia undulata, GC MS, Biodiesel, Gbur, seed oil, Gas Chromatography, Mass. Spectrometry. Correspondence: waneniko@yahoo.co.uk ... these triglycerides and their applications depend on the fatty acid constituents .... injector temperature of 250°C and ion source temperature of 200°C and a split ratio of ...

  15. Gas Chromatography-Mass Spectrometric Analysis of Nematicidal ...

    African Journals Online (AJOL)

    chromatography (GC) and gas chromaotography-mass spectrometry (GC-MS). The nematicidal activity of the essential oil and its major constituents was determined against second stage juveniles of H. avenae. Results: A total of 33 components of the essential oil were identified. The major constituents were bornyl acetate ...

  16. An application of gas chromatography to planetary atmospheres

    Science.gov (United States)

    Oyama, V.

    1974-01-01

    A gas chromatography developed for the Viking experiment is described. The instrument is designed to measure gases in planetary atmospheres and head space in a chamber. It is hoped that the chromatograph will also measure any biological activity present in these environments.

  17. Specialized Gas Chromatography--Mass Spectrometry Systems for Clinical Chemistry.

    Science.gov (United States)

    Gochman, Nathan; And Others

    1979-01-01

    A discussion of the basic design and characteristics of gas chromatography-mass spectrometry systems used in clinical chemistry. A comparison of three specific systems: the Vitek Olfax IIA, Hewlett-Packard HP5992, and Du Pont DP-102 are included. (BB)

  18. Development of a thermal desorption modulator for gas chromatography

    NARCIS (Netherlands)

    Geus, H.J.; Boer, de J.; Brinkman, U.A.Th.

    1997-01-01

    The separation space in gas chromatography can be enhanced dramatically by the comprehensive coupling of two independent separation dimensions. An interface between the two columns must accumulate analytes eluting from the first dimension, focus them and at the appropriate moment transfer them to

  19. Detection of gas entrainment into liquid metals

    Energy Technology Data Exchange (ETDEWEB)

    Vogt, T., E-mail: t.vogt@hzdr.de [Helmholtz-Zentrum Dresden-Rossendorf (HZDR), Institute of Fluid Dynamics, 01328 Dresden (Germany); Boden, S. [Helmholtz-Zentrum Dresden-Rossendorf (HZDR), Institute of Fluid Dynamics, 01328 Dresden (Germany); Andruszkiewicz, A. [Faculty of Mechanical and Power Engineering, Wroclaw University of Technology (Poland); Eckert, K. [Technische Universität Dresden, Institute of Fluid Mechanics, 01062 Dresden (Germany); Eckert, S.; Gerbeth, G. [Helmholtz-Zentrum Dresden-Rossendorf (HZDR), Institute of Fluid Dynamics, 01328 Dresden (Germany)

    2015-12-01

    Highlights: • We present liquid metal experiments dedicated to gas entrainment on the free surface. • Ultrasonic and X-ray attenuation techniques have been used to study the mechanisms of gas entrainment. • A comparison between bubbly flow in water and GaInSn showed substantial differences. • Our results emphasize the importance of liquid metal experiments which are able to provide a suitable data base for numerical code validation. - Abstract: Entrainment of cover gas into the liquid metal coolant is one of the principal safety issues in the design of innovative liquid metal-cooled fast reactors. We present generic experimental studies of this phenomenon in low-melting metals. Ultrasonic and X-ray diagnostic tools were considered for a visualization of gas entrainment at the free surface of the melt. Laboratory experiments were conducted using the eutectic alloy GaInSn, which is liquid at room temperature. Vortex-activated entrainment of air at the free surface of a rotating flow was revealed by ultrasonic techniques. X-ray radioscopy was used to visualize the behavior of argon bubbles inside a slit geometry. The measurements reveal distinct differences between water and GaInSn, especially with respect to the process of bubble formation and the coalescence and breakup of bubbles. Our results emphasize the importance of liquid metal experiments which are able to provide a suitable data base for numerical code validation.

  20. Nanomaterials as stationary phases and supports in liquid chromatography.

    Science.gov (United States)

    Beeram, Sandya R; Rodriguez, Elliott; Doddavenkatanna, Suresh; Li, Zhao; Pekarek, Allegra; Peev, Darin; Goerl, Kathryn; Trovato, Gianfranco; Hofmann, Tino; Hage, David S

    2017-10-01

    The development of various nanomaterials over the last few decades has led to many applications for these materials in liquid chromatography (LC). This review will look at the types of nanomaterials that have been incorporated into LC systems and the applications that have been explored for such systems. A number of carbon-based nanomaterials and inorganic nanomaterials have been considered for use in LC, ranging from carbon nanotubes, fullerenes and nanodiamonds to metal nanoparticles and nanostructures based on silica, alumina, zirconia and titanium dioxide. Many ways have been described for incorporating these nanomaterials into LC systems. These methods have included covalent immobilization, adsorption, entrapment, and the synthesis or direct development of nanomaterials as part of a chromatographic support. Nanomaterials have been used in many types of LC. These applications have included the reversed-phase, normal-phase, ion-exchange, and affinity modes of LC, as well as related methods such as chiral separations, ion-pair chromatography and hydrophilic interaction liquid chromatography. Both small and large analytes (e.g., dyes, drugs, amino acids, peptides and proteins) have been used to evaluate possible applications for these nanomaterial-based methods. The use of nanomaterials in columns, capillaries and planar chromatography has been considered as part of these efforts. Potential advantages of nanomaterials in these applications have included their good chemical and physical stabilities, the variety of interactions many nanomaterials can have with analytes, and their unique retention properties in some separation formats. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Comprehensive Profiling of Phytohormones in Honey by Sequential Liquid-Liquid Extraction Coupled with Liquid Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Wang, Qing; Cai, Wen-Jing; Yu, Lei; Ding, Jun; Feng, Yu-Qi

    2017-01-25

    Honey exhibits various nutritional and medicinal functions, which are highly related to the active components; thus, the exploration of new compounds in honey is of great importance. Because honey is a byproduct of flower nectar, which is rich in phytohormones, the existence of phytohormones in honey is anticipated. In this research, a method for comprehensive profiling of 49 phytohormones in honey was developed by sequential liquid-liquid extraction (LLE) coupled with liquid chromatography-tandem mass spectrometry (LC-MS/MS). Good linearities for 49 phytohormones were obtained with correlation coefficients (R) larger than 0.9913. The limits of detection (LODs) were in the range of 0.2-628.2 pg/mL. Satisfied reproducibility and reliability were achieved by evaluation of the intra- and interday precisions with relative standard deviations (RSDs) less than 15.8% and relative recoveries ranging from 80.4 to 123.7%. The method was further applied to analyze the phytohormones in 14 monofloral raw honey samples and 3 commercial honey samples. The existence of 34 phytohormones was confirmed, including 14 cytokinins (CKs), 8 gibberellins (GAs), 5 brassinosteroids (BRs), indole-3-acetic acid (IAA), indole-3-butyric acid (IBA), abscisic acid (ABA), salicylic acid (SA), jasmonic acid (JA), jasmonoyl-leucine (JA-Leu), and jasmonoyl-phenylalanine (JA-Phe). In addition, the content and species of phytohormones varies in different kinds of honey. The study is beneficial to fully illustrate the phytohormone profile of honey and contributive to elucidate the mechanism of its nutritional and medicinal functions.

  2. Gas chromatography-vacuum ultraviolet spectroscopy for multiclass pesticide identification.

    Science.gov (United States)

    Fan, Hui; Smuts, Jonathan; Walsh, Phillip; Harrison, Dale; Schug, Kevin A

    2015-04-10

    A new vacuum ultraviolet detector for gas chromatography was recently developed and applied to multiclass pesticide identification. VUV detection features full spectral acquisition in a wavelength range of 115-240nm, where virtually all chemical species absorb. VUV absorption spectra of 37 pesticides across different classes were recorded. These pesticides display rich gas phase absorption features across various classes. Even for isomeric compounds, such as hexachlorocyclohexane (HCH) isomers, the VUV absorption spectra are unique and can be easily differentiated. Also demonstrated is the ability to use VUV data analysis software for deconvolution of co-eluting signals. As a universal detector, VUV provides both qualitative and quantitative information. It offers high specificity, sensitivity (pg on-column detection limits), and a fast data acquisition rate, making it a powerful tool for multiclass pesticide screening when combined with gas chromatography. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Quantitative analysis of abused drugs in physiological fluids by gas chromatography/chemical ionization mass spectrometry

    International Nuclear Information System (INIS)

    Foltz, R.L.

    1978-01-01

    Methods have been developed for quantitative analysis of commonly abused drugs in physiological fluids using gas chromatography/chemical ionization mass spectrometry. The methods are being evaluated in volunteer analytical and toxicological laboratories, and analytical manuals describing the methods are being prepared. The specific drug and metabolites included in this program are: Δ 9 -tetrahydrocannabinol, methadone, phencyclidine, methaqualone, morphine, amphetamine, methamphetamine, mescaline, 2,5-dimethoxy-4-methyl amphetamine, cocaine, benzoylecgonine, diazepam, and N-desmethyldiazepam. The current analytical methods utilize relatively conventional instrumentation and procedures, and are capable of measuring drug concentrations as low as 1 ng/ml. Various newer techniques such as sample clean-up by high performance liquid chromatography, separation by glass capillary chromatography, and ionization by negative ion chemical ionization are being investigated with respect to their potential for achieving higher sensitivity and specificity, as well as their ability to facilitate simultaneous analysis of more than one drug and metabolite. (Auth.)

  4. Ionic liquid foam floatation coupled with ionic liquid dispersive liquid-liquid microextraction for the separation and determination of estrogens in water samples by high-performance liquid chromatography with fluorescence detection.

    Science.gov (United States)

    Zhang, Rui; Wang, Chuanliu; Yue, Qiaohong; Zhou, Tiecheng; Li, Na; Zhang, Hanqi; Hao, Xiaoke

    2014-11-01

    An ionic liquid foam floatation coupled with ionic liquid dispersive liquid-liquid microextraction method was proposed for the extraction and concentration of 17-α-estradiol, 17-β-estradiol-benzoate, and quinestrol in environmental water samples by high-performance liquid chromatography with fluorescence detection. 1-Hexyl-3-methylimidazolium tetrafluoroborate was applied as foaming agent in the foam flotation process and dispersive solvent in microextraction. The introduction of the ion-pairing and salting-out agent NH4 PF6 was beneficial to the improvement of recoveries for the hydrophobic ionic liquid phase and analytes. Parameters of the proposed method including concentration of 1-hexyl-3-methylimidazolium tetrafluoroborate, flow rate of carrier gas, floatation time, types and concentration of ionic liquids, salt concentration in samples, extraction time, and centrifugation time were evaluated. The recoveries were between 98 and 105% with relative standard deviations lower than 7% for lake water and well water samples. The isolation of the target compounds from the water was found to be efficient, and the enrichment factors ranged from 4445 to 4632. This developing method is free of volatile organic solvents compared with regular extraction. Based on the unique properties of ionic liquids, the application of foam floatation, and dispersive liquid-liquid microextraction was widened. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. VIII All-Russian symposium on molecular liquid chromatography and capillary electrophoresis. Program. Summary of reports

    International Nuclear Information System (INIS)

    2001-01-01

    Program and summary of reports of the VIII All-Russian symposium on molecular liquid chromatography and capillary electrophoresis are performed. The meeting took place 15-19 October, 2001 in Moscow. Many problems of liquid and ion exchange chromatography, capillary electrophoresis, thin-layer chromatography have been discussed extensively. Reports covering properties of sorbents and devices for chromatography are incorporated in the collection [ru

  6. Increasing flexibility in two-dimensional liquid chromatography by pulsed elution of the first dimension

    DEFF Research Database (Denmark)

    Jakobsen, Simon S.; Christensen, Jan H.; Verdier, Sylvain

    2017-01-01

    This work demonstrates the development of an online two-dimensional liquid chromatography (2D-LC) method where the first dimension column is eluted by a sequence of pulses of increasing eluotropic strength generated by the LC pumps (pulsed-elution 2D-LC). Between the pulses, the first dimension...... online comprehensive 2D-LC: undersampling, difficulties in refocusing, and lack of flexibility in the selection of column dimensions and flow rates because the two dimensions constrain each other. The pulsed-elution 2D-LC was applied for the analysis of a basic fraction of vacuum gas oil. Peak capacity...

  7. Gas-liquid separator and method of operation

    Science.gov (United States)

    Soloveichik, Grigorii Lev [Latham, NY; Whitt, David Brandon [Albany, NY

    2009-07-14

    A system for gas-liquid separation in electrolysis processes is provided. The system includes a first compartment having a liquid carrier including a first gas therein and a second compartment having the liquid carrier including a second gas therein. The system also includes a gas-liquid separator fluidically coupled to the first and second compartments for separating the liquid carrier from the first and second gases.

  8. Protein Mobility Shifts Contribute to Gel Electrophoresis Liquid Chromatography Analysis.

    Science.gov (United States)

    Carruthers, Nicholas J; Parker, Graham C; Gratsch, Theresa; Caruso, Joseph A; Stemmer, Paul M

    2015-09-01

    Profiling of cellular and subcellular proteomes by liquid chromatography with tandem mass spectrometry (MS) after fractionation by SDS-PAGE is referred to as GeLC (gel electrophoresis liquid chromatography)-MS. The GeLC approach decreases complexity within individual MS analyses by size fractionation with SDS-PAGE. SDS-PAGE is considered an excellent fractionation technique for intact proteins because of good resolution for proteins of all sizes, isoelectric points, and hydrophobicities. Additional information derived from the mobility of the intact proteins is available after an SDS-PAGE fractionation, but that information is usually not incorporated into the proteomic analysis. Any chemical or proteolytic modification of a protein that changes the mobility of that protein in the gel can be detected. The ability of SDS-PAGE to resolve proteins with chemical modifications has not been widely utilized within profiling experiments. In this work, we examined the ability of the GeLC-MS approach to help identify proteins that were modified after a small hairpin RNA-dependent knockdown in an experiment using stable isotope labeling by amino acids in cell culture-based quantitation.

  9. Liquid Chromatography-Tandem Mass Spectrometry: An Emerging Technology in the Toxicology Laboratory.

    Science.gov (United States)

    Zhang, Yan Victoria; Wei, Bin; Zhu, Yu; Zhang, Yanhua; Bluth, Martin H

    2016-12-01

    In the last decade, liquid chromatography-tandem mass spectrometry (LC-MS/MS) has seen enormous growth in routine toxicology laboratories. LC-MS/MS offers significant advantages over other traditional testing, such as immunoassay and gas chromatography-mass spectrometry methodologies. Major strengths of LC-MS/MS include improvement in specificity, flexibility, and sample throughput when compared with other technologies. Here, the basic principles of LC-MS/MS technology are reviewed, followed by advantages and disadvantages of this technology compared with other traditional techniques. In addition, toxicology applications of LC-MS/MS for simultaneous detection of large panels of analytes are presented. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Gas Marbles: Much Stronger than Liquid Marbles

    Science.gov (United States)

    Timounay, Yousra; Pitois, Olivier; Rouyer, Florence

    2017-06-01

    Enwrapping liquid droplets with hydrophobic particles allows the manufacture of so-called "liquid marbles" [Aussillous and Quéré Nature (London) 411, 924 (2001); , 10.1038/35082026Mahadevan Nature (London)411, 895 (2001), 10.1038/35082164]. The recent intensive research devoted to liquid marbles is justified by their very unusual physical and chemical properties and by their potential for various applications, from microreactors to water storage, including water pollution sensors [Bormashenko Curr. Opin. Colloid Interface Sci. 16, 266 (2011), 10.1016/j.cocis.2010.12.002]. Here we demonstrate that this concept can be successfully applied for encapsulating and protecting small gas pockets within an air environment. Similarly to their liquid counterparts, those new soft-matter objects, that we call "gas marbles," can sustain external forces. We show that gas marbles are surprisingly tenfold stronger than liquid marbles and, more importantly, they can sustain both positive and negative pressure differences. This magnified strength is shown to originate from the strong cohesive nature of the shell. Those interesting properties could be exploited for imprisoning valuable or polluted gases or for designing new aerated materials.

  11. Adiabatic gas-liquid flow

    International Nuclear Information System (INIS)

    Mayinger, F.

    1982-01-01

    The author starts by discussing the gas-fluidic mixture, its application and its special characteristics. The conservation theorems for these mixtures are then presented, including the continuity equation, the impulse equation, and energy balance. The type of flow in vertical channels, vertical downwards flow and flow in horizontal and inclined tubes is discussed followed by a short section on local volumetric steam contents and slip. The expressions for the slip and for the local volumetric steam contents are explained before discussing phase separation in nonflowing fluids. Pressure loss in tubes and channels is followed by discussion of pressure loss in various types of moulded bodies with particular reference to fuel rod bundles. In conclusion the author discusses pressure wave expansion, critical discharge and cross exchange in sub-divided channels. (A.N.K.)

  12. Application of gas chromatography to the investigations on polypropylene radiolysis

    International Nuclear Information System (INIS)

    Zagorski, Z.P.; Gluszewski, W.

    2006-01-01

    Refinement of the gas chromatography (GC) instrumental approach permitted not only improvement of investigation in basic research, but also development of a new kind of polypropylene blends, more suitable for the production of medical devices and radiation sterilization. It has been shown, that using the GC method not only methane and carbon dioxide can be measured, but also the consumption of oxygen which reacts with free radicals on the polypropylene chain

  13. Purification of flavonoids from licorice using an off-line preparative two-dimensional normal-phase liquid chromatography/reversed-phase liquid chromatography method.

    Science.gov (United States)

    Fan, Yunpeng; Fu, Yanhui; Fu, Qing; Cai, Jianfeng; Xin, Huaxia; Dai, Mei; Jin, Yu

    2016-07-01

    An orthogonal (71.9%) off-line preparative two-dimensional normal-phase liquid chromatography/reversed-phase liquid chromatography method coupled with effective sample pretreatment was developed for separation and purification of flavonoids from licorice. Most of the nonflavonoids were firstly removed using a self-made Click TE-Cys (60 μm) solid-phase extraction. In the first dimension, an industrial grade preparative chromatography was employed to purify the crude flavonoids. Click TE-Cys (10 μm) was selected as the stationary phase that provided an excellent separation with high reproducibility. Ethyl acetate/ethanol was selected as the mobile phase owing to their excellent solubility for flavonoids. Flavonoids co-eluted in the first dimension were selected for further purification using reversed-phase liquid chromatography. Multiple compounds could be isolated from one normal-phase fraction and some compounds with bad resolution in one-dimensional liquid chromatography could be prepared in this two-dimensional system owing to the orthogonal separation. Moreover, this two-dimensional liquid chromatography method was beneficial for the preparation of relatively trace flavonoid compounds, which were enriched in the first dimension and further purified in the second dimension. Totally, 24 flavonoid compounds with high purity were obtained. The results demonstrated that the off-line two-dimensional liquid chromatography method was effective for the preparative separation and purification of flavonoids from licorice. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Establishment of analysis method for methane detection by gas chromatography

    Science.gov (United States)

    Liu, Xinyuan; Yang, Jie; Ye, Tianyi; Han, Zeyu

    2018-02-01

    The study focused on the establishment of analysis method for methane determination by gas chromatography. Methane was detected by hydrogen flame ionization detector, and the quantitative relationship was determined by working curve of y=2041.2x+2187 with correlation coefficient of 0.9979. The relative standard deviation of 2.60-6.33% and the recovery rate of 96.36%∼105.89% were obtained during the parallel determination of standard gas. This method was not quite suitable for biogas content analysis because methane content in biogas would be over the measurement range in this method.

  15. Chelate-modified polymers for atmospheric gas chromatography

    Science.gov (United States)

    Christensen, W. W.; Mayer, L. A.; Woeller, F. H. (Inventor)

    1980-01-01

    Chromatographic materials were developed to serve as the stationary phase of columns used in the separation of atmospheric gases. These materials consist of a crosslinked porous polymer matrix, e.g., a divinylbenzene polymer, into which has been embedded an inorganic complexed ion such as N,N'-ethylene-bis-(acetylacetoniminato)-cobalt (2). Organic nitrogenous bases, such as pyridine, may be incorporated into the chelate polymer complexes to increase their chromatographic utility. With such materials, the process of gas chromatography is greatly simplified, especially in terms of time and quantity of material needed for a gas separation.

  16. Reduction of silanophilic interactions in liquid chromatography with the use of ionic liquids

    International Nuclear Information System (INIS)

    MarszaII, MichaI Piotr; Baczek, Tomasz; Kaliszan, Roman

    2005-01-01

    A suppression of silanophilic interactions by the selected ionic liquids added to the mobile phase in thin-layer chromatography (TLC) and high-performance liquid chromatography (HPLC) is reported. Acetonitrile was used as the eluent, alone or with various concentrations of water and phosphoric buffer pH 3. Selectivity of the normal (NP) and the reversed (RP) stationary phase material was examined using a series of proton-acceptor basic drugs analytes. The ionic liquids studied appeared to significantly affect analyte retention in NP-TLC, RP-TLC and RP-HPLC systems tested. Consequently, the increased separation selectivity was attained. Due to ionic liquid additives to eluent even analytes could be chromatographed, which were not eluted from the silica-based stationary phase materials with 100% of acetonitrile in the mobile phase. Addition of ionic liquid already in very small concentration (0.5%, v/v) could reduce the amount of acetonitrile used during the optimization of basic analytes separations in TLC and HPLC systems. Moreover, the influence of temperature on the separation of basic analytes was demonstrated and considered in practical HPLC method development

  17. Reduction of silanophilic interactions in liquid chromatography with the use of ionic liquids

    Energy Technology Data Exchange (ETDEWEB)

    MarszaII, MichaI Piotr [Department of Biopharmaceutics and Pharmacodynamics, Medical University of Gdansk, Gen. J. Hallera 107, 80-416 Gdansk (Poland); Baczek, Tomasz [Department of Biopharmaceutics and Pharmacodynamics, Medical University of Gdansk, Gen. J. Hallera 107, 80-416 Gdansk (Poland); Kaliszan, Roman [Department of Biopharmaceutics and Pharmacodynamics, Medical University of Gdansk, Gen. J. Hallera 107, 80-416 Gdansk (Poland)]. E-mail: roman.kaliszan@amg.gda.pl

    2005-08-22

    A suppression of silanophilic interactions by the selected ionic liquids added to the mobile phase in thin-layer chromatography (TLC) and high-performance liquid chromatography (HPLC) is reported. Acetonitrile was used as the eluent, alone or with various concentrations of water and phosphoric buffer pH 3. Selectivity of the normal (NP) and the reversed (RP) stationary phase material was examined using a series of proton-acceptor basic drugs analytes. The ionic liquids studied appeared to significantly affect analyte retention in NP-TLC, RP-TLC and RP-HPLC systems tested. Consequently, the increased separation selectivity was attained. Due to ionic liquid additives to eluent even analytes could be chromatographed, which were not eluted from the silica-based stationary phase materials with 100% of acetonitrile in the mobile phase. Addition of ionic liquid already in very small concentration (0.5%, v/v) could reduce the amount of acetonitrile used during the optimization of basic analytes separations in TLC and HPLC systems. Moreover, the influence of temperature on the separation of basic analytes was demonstrated and considered in practical HPLC method development.

  18. Determination of sulfonamides in butter samples by ionic liquid magnetic bar liquid-phase microextraction high-performance liquid chromatography.

    Science.gov (United States)

    Wu, Lijie; Song, Ying; Hu, Mingzhu; Xu, Xu; Zhang, Hanqi; Yu, Aimin; Ma, Qiang; Wang, Ziming

    2015-01-01

    A novel, simple, and environmentally friendly pretreatment method, ionic liquid magnetic bar liquid-phase microextraction, was developed for the determination of sulfonamides in butter samples by high-performance liquid chromatography. The ionic liquid magnetic bar was prepared by inserting a stainless steel wire into the hollow of a hollow fiber and immobilizing ionic liquid in the micropores of the hollow fiber. In the extraction process, the ionic liquid magnetic bars were used to stir the mixture of sample and extraction solvent and enrich the sulfonamides in the mixture. After extraction, the analyte-adsorbed ionic liquid magnetic bars were readily isolated with a magnet from the extraction system. It is notable that the present method was environmentally friendly since water and only several microliters of ionic liquid were used in the whole extraction process. Several parameters affecting the extraction efficiency were investigated and optimized, including the type of ionic liquid, sample-to-extraction solvent ratio, the number of ionic liquid magnetic bars, extraction temperature, extraction time, salt concentration, stirring speed, pH of the extraction solvent, and desorption conditions. The recoveries were in the range of 73.25-103.85 % and the relative standard deviations were lower than 6.84 %. The experiment results indicated that the present method was effective for the extraction of sulfonamides in high-fat content samples.

  19. Determination of Rocuronium bromide by hydrophilic interaction liquid chromatography (HILIC

    Directory of Open Access Journals (Sweden)

    Natalija Nakov

    2012-01-01

    Full Text Available A new method involving hydrophilic interaction liquid chromatography (HILIC has been developed for determination of rocuronium bromide in presents of its main impurities (impurity A and impurity C, which are also its main degradation products, in solution for injection. The influence of the critical chromatographic parameters such as content of acetonitrile in the mobile phase, ionic strength and pH value of the buffer used in the mobile phase were investigated using the Design of experiments approach (DoE. The mechanism of retention of rocuronium bromide on bare silica column was also investigated. Optimal chromatographic conditions were obtained using mixture of acetonitrile and ammonium formate (107.5mM, pH 7.0 in ratio 90:10 as a mobile phase. The validation results have shown that the method is suitable for determination of rocuronium bromid in solution for injection.

  20. Alcoholic fermentation process control by high-performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Morawski, J.; Dincer, A.K.; Ivie, K.

    1983-02-01

    In large-scale fermentation for energy production high-performance liquid chromatography (HPLC) provides an accurate method of monitoring the original oligosaccharides and polysaccharides, as well as their hydrolysis to fermentable monosaccharides. Also measuring the saccharide and alcohol content of the fermentation vat allows overseeing of the process, providing the capability of allowing the fermentation to proceed to the most economical level prior to distillation. Another application for HPLC in a large-scale fermentation for energy is to analyze the stillage for its ethanol content during distillation, in order to observe the efficiency of the still. HPLC can separate and detect very low levels, (i.e., 100 parts per million), of ethanol to yield information concerning the distillation process. These capabilities indicate that HPLC is an extremely useful efficient instrument to the fermentation industries. (Refs. 2).

  1. A rapid liquid chromatography determination of free formaldehyde in cod.

    Science.gov (United States)

    Storey, Joseph M; Andersen, Wendy C; Heise, Andrea; Turnipseed, Sherri B; Lohne, Jack; Thomas, Terri; Madson, Mark

    2015-01-01

    A rapid method for the determination of free formaldehyde in cod is described. It uses a simple water extraction of formaldehyde which is then derivatised with 2,4-dinitrophenylhydrazine (DNPH) to form a sensitive and specific chromophore for high-performance liquid chromatography (HPLC) detection. Although this formaldehyde derivative has been widely used in past tissue analysis, this paper describes an improved derivatisation procedure. The formation of the DNPH formaldehyde derivative has been shortened to 2 min and a stabilising buffer has been added to the derivative to increase its stability. The average recovery of free formaldehyde in spiked cod was 63% with an RSD of 15% over the range of 25-200 mg kg(-1) (n = 48). The HPLC procedure described here was also compared to a commercial qualitative procedure - a swab test for the determination of free formaldehyde in fish. Several positive samples were compared by both methods.

  2. Micro parallel liquid chromatography: enabling technology for discovery analytical chemistry.

    Science.gov (United States)

    Lemmo, Anthony V; Hobbs, Steve; Patel, Paren

    2004-08-01

    Since the introduction of combinatorial chemistry, compound libraries have undergone a significant increase in size and diversity. The ensuing expansion and diversification of compound libraries have resulted in increased demand for analytical throughput. Following the evolution of new technologies for generating lead compounds and targets and the desire to increase research and development productivity, analytical chemistry is now gaining attention as a bottleneck that would benefit from advances in instrumentation for increased analytical throughput. The commercial introduction of the Veloce trade mark micro parallel liquid chromatography system from Nanostream offers discovery analytical chemists the capability to analyze 24 samples in parallel with as little as 0.5 microl of sample. The system offers a scalable analytical approach to address bottlenecks in historically underserved areas, such as compound library purity screening, as well as higher value-added applications, such as log P determination and aqueous solubility assessment. This article describes the Veloce system and presents representative data from several discovery analytical applications.

  3. Liquid chromatography mass spectrometry for analysis of microbial metabolites

    DEFF Research Database (Denmark)

    Klitgaard, Andreas

    are still to be discovered. The main analytical technique used to investigate production of products from these diverse organisms is liquid-chromatography coupled to mass spectrometry (LC-MS). With the development of new and improved analytical instrumentation for chemical analysis, the time needed...... the recorded LC-MS data and annotate known compounds, a process we have named aggressive dereplication. By overlaying automatically generated extracted-ion chromatograms from detected compounds on the base peak chromatogram, all major potentially novel peaks can be visualized, allowing for fast dereplication...... and methodologies developed during these studies have shown to be very effective and applicable to metabolite analysis of a wide range of microorganisms, and not restricted to fungi. The developed methods have revealed new insights into microbial SMs, and it is clear that even more discoveries can be made using...

  4. Gradient design for liquid chromatography using multi-scale optimization.

    Science.gov (United States)

    López-Ureña, S; Torres-Lapasió, J R; Donat, R; García-Alvarez-Coque, M C

    2018-01-26

    In reversed phase-liquid chromatography, the usual solution to the "general elution problem" is the application of gradient elution with programmed changes of organic solvent (or other properties). A correct quantification of chromatographic peaks in liquid chromatography requires well resolved signals in a proper analysis time. When the complexity of the sample is high, the gradient program should be accommodated to the local resolution needs of each analyte. This makes the optimization of such situations rather troublesome, since enhancing the resolution for a given analyte may imply a collateral worsening of the resolution of other analytes. The aim of this work is to design multi-linear gradients that maximize the resolution, while fulfilling some restrictions: all peaks should be eluted before a given maximal time, the gradient should be flat or increasing, and sudden changes close to eluting peaks are penalized. Consequently, an equilibrated baseline resolution for all compounds is sought. This goal is achieved by splitting the optimization problem in a multi-scale framework. In each scale κ, an optimization problem is solved with N κ  ≈ 2 κ variables that are used to build the gradients. The N κ variables define cubic splines written in terms of a B-spline basis. This allows expressing gradients as polygonals of M points approximating the splines. The cubic splines are built using subdivision schemes, a technique of fast generation of smooth curves, compatible with the multi-scale framework. Owing to the nature of the problem and the presence of multiple local maxima, the algorithm used in the optimization problem of each scale κ should be "global", such as the pattern-search algorithm. The multi-scale optimization approach is successfully applied to find the best multi-linear gradient for resolving a mixture of amino acid derivatives. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Towards Chip Scale Liquid Chromatography and High Throughput Immunosensing

    Energy Technology Data Exchange (ETDEWEB)

    Ni, Jing [Iowa State Univ., Ames, IA (United States)

    2000-09-21

    This work describes several research projects aimed towards developing new instruments and novel methods for high throughput chemical and biological analysis. Approaches are taken in two directions. The first direction takes advantage of well-established semiconductor fabrication techniques and applies them to miniaturize instruments that are workhorses in analytical laboratories. Specifically, the first part of this work focused on the development of micropumps and microvalves for controlled fluid delivery. The mechanism of these micropumps and microvalves relies on the electrochemically-induced surface tension change at a mercury/electrolyte interface. A miniaturized flow injection analysis device was integrated and flow injection analyses were demonstrated. In the second part of this work, microfluidic chips were also designed, fabricated, and tested. Separations of two fluorescent dyes were demonstrated in microfabricated channels, based on an open-tubular liquid chromatography (OT LC) or an electrochemically-modulated liquid chromatography (EMLC) format. A reduction in instrument size can potentially increase analysis speed, and allow exceedingly small amounts of sample to be analyzed under diverse separation conditions. The second direction explores the surface enhanced Raman spectroscopy (SERS) as a signal transduction method for immunoassay analysis. It takes advantage of the improved detection sensitivity as a result of surface enhancement on colloidal gold, the narrow width of Raman band, and the stability of Raman scattering signals to distinguish several different species simultaneously without exploiting spatially-separated addresses on a biochip. By labeling gold nanoparticles with different Raman reporters in conjunction with different detection antibodies, a simultaneous detection of a dual-analyte immunoassay was demonstrated. Using this scheme for quantitative analysis was also studied and preliminary dose-response curves from an immunoassay of a

  6. Behavior of macroporous vinyl silica and silica monolithic columns in high pressure gas chromatography.

    Science.gov (United States)

    Maniquet, Adrien; Bruyer, Nicolas; Raffin, Guy; Baco-Antionali, Franck; Demesmay, Claire; Dugas, Vincent; Randon, Jérôme

    2017-06-30

    80% vinyltrimethoxysilane-based hybrid silica monoliths (80-VTMS), which have been initially developed for separation in reversed-phase liquid chromatography, have been investigated in high pressure gas chromatography separations (carrier gas pressure up to 60bar) and compared to silica monolithic columns. The behavior of both silica and 80-VTMS monolithic columns was investigated using helium, nitrogen and carbon dioxide as carrier gas. The efficiency of 80-VTMS monolithic columns was shown to vary differently than silica monolithic columns according to the temperature and the carrier gas used. Carrier gas nature was a significant parameter on the retention for both silica and vinyl columns in relation to its adsorption onto the stationary phase in such high pressure conditions. The comparison of retention and selectivity between 80-VTMS monoliths and silica was performed under helium using the logarithm of the retention factor according to the number of carbon atoms combined to Kovats indexes. The very good performances of these columns were demonstrated, allowing the separation of 8 compounds in less than 1min. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Recent advances in ultra-high performance liquid chromatography for the analysis of traditional chinese medicine

    Science.gov (United States)

    Traditional Chinese medicines (TCMs) have been widely used for the prevention and treatment of various diseases for thousands of years in China. Ultra Performance Liquid Chromatography (UHPLC) is a relatively new technique offering new possibilities in liquid chromatography. This paper reviews recen...

  8. Investigating the Retention Mechanisms of Liquid Chromatography Using Solid-Phase Extraction Cartridges

    Science.gov (United States)

    O'Donnell, Mary E.; Musial, Beata A.; Bretz, Stacey Lowery; Danielson, Neil D.; Ca, Diep

    2009-01-01

    Liquid chromatography (LC) experiments for the undergraduate analytical laboratory course often illustrate the application of reversed-phase LC to solve a separation problem, but rarely compare LC retention mechanisms. In addition, a high-performance liquid chromatography instrument may be beyond what some small colleges can purchase. Solid-phase…

  9. Analytical method for high resolution liquid chromatography for quality control French Macaw

    International Nuclear Information System (INIS)

    Garcia Penna, Caridad M; Torres Amaro, Leonid; Menendez Castillo, Rosa; Sanchez, Esther; Martinez Espinosa, Vivian; Gonzalez, Maria Lidia; Rodriguez, Carlos

    2007-01-01

    Was developed and validated an analytical method for high resolution liquid chromatography applicable to quality control of drugs dry French Macaw (Senna alata L. Roxb.) With ultraviolet detection at 340 nm. The method for high resolution liquid chromatography used to quantify the sennosides A and B, main components, was validated and proved to be specific, linear, precise and accurate. (Author)

  10. Prediction onset and dynamic behaviour of liquid loading gas wells

    NARCIS (Netherlands)

    Belfroid, S.P.C.; Schiferli, W.; Alberts, G.J.N.; Veeken, C.A.M.; Biezen, E.

    2008-01-01

    As reservoir pressures decrease in maturing gas wells, liquid drop-out forms an increasing restriction on gas production. Even though virtually all of the world's gas wells are either at risk of or suffering from liquid loading, the modeling of liquid loading behavior is still quite immature and the

  11. Gas chromatography analysisof organic compounds labelled with 14C and T

    International Nuclear Information System (INIS)

    Matukha, M.; Zhilka, L.; Khejze, K.-Kh.; Gehrner, Kh.

    1982-01-01

    Various methods of radio gas chromatography (RGC) including non-destructiveones are analyzed and compared as well as systems for their realization. The selected methods were verified in interlaboratory studies. The developed RGC-system produce a linear output signal proportional to the measured sample activity within 10 to 200 kBg. The system includes a nondestructive mass and radioactivity detector in series with combustion chamber of the effluent after TCD passage and 14 CO 2 absorber with ethanolamine. The activity of obtained solution is measured by means of liquid scintillation method [ru

  12. Analysis of the anthraquinones aloe-emodin and aloin by gas chromatography/mass spectrometry.

    Science.gov (United States)

    ElSohly, Mahmoud A; Gul, Waseem; Murphy, Timothy P

    2004-12-20

    A procedure was developed for the determination of low levels of the anthraquinones aloe-emodin and aloin A (barbalin) in aloe products based on gas chromatography/mass spectrometry (GC/MS) of the trimethyl silyl (TMS) derivatives of these analytes in the presence of Chrysophanol used as internal standard. The method was used to analyze several aloe based commercial products (liquids, gels and solids). Wide variation in the level of these anthraquinones was observed among the different products. The method had a sensitivity of 0.005 ppm of aloe-emodin and 0.05 ppm of aloin.

  13. Pressurized liquid extraction followed by liquid chromatography with tandem mass spectrometry to determine pharmaceuticals in mussels.

    Science.gov (United States)

    Núñez, Mireia; Borrull, Francesc; Pocurull, Eva; Fontanals, Núria

    2016-02-01

    An analytical method based on pressurized liquid extraction and solid-phase extraction with a mixed-mode Oasis(®) MAX sorbent as cleanup, followed by liquid chromatography with electrospray ionization and tandem mass spectrometry was developed and validated for the determination of seven widely used pharmaceuticals in mussel species. The optimization of the pressurized liquid extraction and the solid-phase extraction parameters is described. The method provided extraction recoveries ranging from 61 to 90%, and limits of detection ranging from 2 to 50 ng/g (dry weight). The repeatability and reproducibility of the method, expressed as relative standard deviation, were lower than 15 and 19%, respectively. The method was successfully applied to the analysis of mussel samples from different locations. The analyses showed that salicylic acid was present in mussels at concentrations up to 177 ng/g (dry weight). © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. A comprehensive procedure based on gas chromatography–isotope ratio mass spectrometry following high performance liquid chromatography purification for the analysis of underivatized testosterone and its analogues in human urine

    International Nuclear Information System (INIS)

    Torre, Xavier de la; Colamonici, Cristiana; Curcio, Davide; Molaioni, Francesco; Botrè, Francesco

    2012-01-01

    Highlights: ► Overall approach for urine samples purification by HPLC for subsequent GC/C/IRMS analysis in doping control. ► Detection of pseudo-endogenous androgenic steroids (i.e. testosterone, androstenedione) misuse in sports. ► Routine analysis of steroids by GC/C/IRMS in sports drug testing. - Abstract: The confirmation by GC/C/IRMS of the exogenous origin of pseudo-endogenous steroids from human urine samples requires extracts of adequate purity. A strategy based on HPLC sample purification prior to the GC/C/IRMS analysis of human urinary endogenous androgens (i.e. testosterone, androsterone and/or androstenediols), is presented. A method without any additional derivatization step is proposed, allowing to simplify the urine pretreatment procedure, leading to extracts free of interferences permitting precise and accurate IRMS analysis, without the need of correcting the measured delta values for the contribution of the derivatizing agent. The HPLC extracts were adequately combined to both reduce the number of GC/C/IRMS runs and to have appropriate endogenous reference compounds (ERC; i.e. pregnanediol, 11-keto-etiocholanolone) on each GC–IRMS run. The purity of the extracts was assessed by their parallel analysis by gas chromatography coupled to mass spectrometry, with GC conditions identical to those of the GC/C/IRMS assay. The method has been validated according to ISO17025 requirements (within assay precision below 0.3 ‰ 13 C delta units and between assay precision below 0.6 ‰ 13 C delta units for most of the compounds investigated) fulfilling the World Anti-Doping Agency requirements.

  15. Transient multiphase flow modeling of gas well liquid loading

    NARCIS (Netherlands)

    Veeken, K.; Hu, B.; Schiferli, W.

    2009-01-01

    Gas well liquid loading occurs when gas production becomes insufficient to lift the associated liquids to surface. When that happens gas production first turns intermittent and eventually stops. Hence in depleting gas reservoirs the technical abandonment pressure and ultimate recovery are typically

  16. Investigation of borneols sold in Taiwan by chiral gas chromatography

    Directory of Open Access Journals (Sweden)

    Tsung-Jung Ho

    2018-01-01

    Full Text Available Borneol is a monoterpene that is widely used in traditional Chinese medicine. There are two different products sold in Taipei's traditional Chinese medicine market, natural and chemically synthesized borneol. Chemically synthesized borneol contains four stereoisomers, (+-isoborneol, (−-isoborneol, (−-borneol, and (+-borneol. The ratio of these four isomers in chemically synthesized and natural borneol products was determined by gas chromatography mass spectrometry. A huge variation between these products is highlighted in this survey. The results suggest that the Food and Drug Administrations in Asian countries should establish a regulatory standard regarding the ratio of the four different borneol isomers in both natural and chemically synthesized borneol.

  17. Analysis of artificial fireplace logs by high temperature gas chromatography.

    Science.gov (United States)

    Kuk, Raymond J

    2002-11-01

    High temperature gas chromatography is used to analyze the wax of artificial fireplace logs (firelogs). Firelogs from several different manufacturers are studied and compared. This study shows that the wax within a single firelog is homogeneous and that the wax is also uniform throughout a multi-firelog package. Different brands are shown to have different wax compositions. Firelogs of the same brand, but purchased in different locations, also have different wax compositions. With this information it may be possible to associate an unknown firelog sample to a known sample, but a definitive statement of the origin cannot be made.

  18. [Determination of acetochlor and oxyfluorfen by capillary gas chromatography].

    Science.gov (United States)

    Xiang, Wen-Sheng; Wang, Xiang-Jing; Wang, Jing; Wang, Qing

    2002-09-01

    A method is described for the determination of acetochlor and oxyfluorfen by capillary gas chromatography with FID and an SE-30 capillary column (60 m x 0.53 mm i. d., 1.5 microm), using dibutyl phthalate as the internal standard. The standard deviations for acetochlor and oxyfluorfen concentration(mass fraction) were 0.44% and 0.47% respectively. The relative standard deviations for acetochlor and oxyfluorfen were 0.79% and 0.88% and the average recoveries for acetochlor and oxyfluorfen were 99.3% and 101.1% respectively. The method is simple, rapid and accurate.

  19. Diesel characterization by high-resolution mass spectrometry - gas chromatography

    International Nuclear Information System (INIS)

    Baldrich, C.A

    1998-01-01

    High-resolution mass spectrometry-gas chromatography is combined with the HC22 method in order to obtain detailed information about the chemical composition of diesel and the distribution of different compound types in terms of its final boiling temperature from a single analysis. The total time elapsed from sample injection and signal processing to obtain final results is 90 minutes. This fact makes this methodology a new and very important tool for the decision making process concerning the most suitable final boiling temperature and the type of treatment of the product in order to obtain diesel that fulfills the international standards. The consistency and repeatability of the experimental results are demonstrated

  20. Continuous monitoring of a changing sample by multiplex gas chromatography

    Science.gov (United States)

    Valentin, Jose R.; Hall, Kirsten W.; Becker, Joseph F.

    1990-01-01

    Results are presented from a study in which a continuously changed gaseous sample was monitored by multiplex gas chromatography (MGC), using the exponential dilution (ED) technique of Ritter and Adams (1976) to change the composition and concentration of a gaseous mixture in such a way as to imitate changes in the atmospheric gases sampled by a descending aircraft. A calibration of the MGC system was performed with four different rates of sample dilution, and the errors resulting from various degrees of change in the sample concentration were determined.

  1. Continuous gas/liquid–liquid/liquid flow synthesis of 4-fluoropyrazole derivatives by selective direct fluorination

    Directory of Open Access Journals (Sweden)

    Jessica R. Breen

    2011-08-01

    Full Text Available 4-Fluoropyrazole systems may be prepared by a single, sequential telescoped two-step continuous gas/liquid–liquid/liquid flow process from diketone, fluorine gas and hydrazine starting materials.

  2. Continuous determination of volatile products in anaerobic fermenters by on-line capillary gas chromatography

    International Nuclear Information System (INIS)

    Diamantis, V.; Melidis, P.; Aivasidis, A.

    2006-01-01

    Bio-ethanol and biogas produced during the anaerobic conversion of organic compounds has been a subject of great interest since the oil crisis of the 1970s. In ethanol fermentation and anaerobic treatment of wastewaters, end-product (ethanol) and intermediate-products (short-chain fatty acids, SCFA) cause inhibition that results in reduced process efficiency. Control of these constituents is of utmost importance for bioreactor optimization and process stability. Ethanol and SCFA can be detected with precision by capillary gas chromatography usually conducted in off-line measurements. In this work, an on-line monitoring and controlling system was developed and connected to the fermenter via an auto-sampling equipment, which could perform the feeding, filtration and dilution of the sample and final injection into the gas chromatograph through an automation-based programmed procedure. The sample was continuously pumped from the recycle stream of the bioreactor and treated using a microfiltration unit. The concentrate was returned to the reactor while the permeate was quantitatively mixed with an internal standard solution. The system comprised of a gas chromatograph with the flow cell and one-shot sampler and a PC with the appropriate software. The on-line measurement of ethanol and SCFA, directly from the liquid phase of an ethanol fermenter and a high-rate continuous mode anaerobic digester, was accomplished by gas chromatography. Also, this monitoring and controlling system was proved to be effective in the continuous fermentation of alcohol-free beer

  3. Simultaneous analysis of (13)C-glutathione as its dimeric form GSSG and its precursor [1-(13)C]glycine using liquid chromatography/isotope ratio mass spectrometry

    NARCIS (Netherlands)

    Schierbeek, Henk; Rook, Denise; te Braake, Frans W. J.; Dorst, Kristien Y.; Voortman, Gardi; Godin, Jean-Philippe; Fay, Laurent-Bernard; van Goudoever, Johannes B.

    2009-01-01

    Determination of glutathione kinetics using stable isotopes requires accurate measurement of the tracers and tracees. Previously, the precursor and synthesized product were measured with two separate techniques, liquid chromatography/isotope ratio mass spectrometry (LC/IRMS) and gas

  4. Screening of drugs and toxic compounds with liquid chromatography-linear ion trap tandem mass spectrometry.

    Science.gov (United States)

    Sauvage, François-Ludovic; Saint-Marcoux, Franck; Duretz, Bénédicte; Deporte, Didier; Lachatre, Gérard; Marquet, Pierre

    2006-09-01

    In clinical and forensic toxicology, general unknown screening is used to detect and identify exogenous compounds. In this study, we aimed to develop a comprehensive general unknown screening method based on liquid chromatography coupled with a hybrid triple-quadrupole linear ion trap mass spectrometer. After solid-phase extraction, separation was performed using gradient reversed-phase chromatography. The mass spectrometer was operated in the information-dependent acquisition mode, switching between a survey scan acquired in the Enhanced Mass Spectrometry mode with dynamic subtraction of background noise and a dependent scan obtained in the enhanced product ion scan mode. The complete cycle time was 1.36 s. A library of 1000 enhanced product ion-tandem mass spectrometry spectra in positive mode and 250 in negative mode, generated using 3 alternated collision tensions during each scan, was created by injecting pure solutions of drugs and toxic compounds. Comparison with HPLC-diode array detection and gas chromatography-mass spectrometry for the analysis of 36 clinical samples showed that linear ion trap tandem mass spectrometry could identify most of the compounds (94% of the total). Some compounds were detected only by 1 of the other 2 techniques. Specific clinical cases highlighted the advantages and limitations of the method. A unique combination of new operating modes provided by hybrid triple-quadrupole linear ion trap mass spectrometers and new software features allowed development of a comprehensive and efficient method for the general unknown screening of drugs and toxic compounds in blood or urine.

  5. Evaluation of a gas chromatography method for azelaic acid determination in selected biological samples.

    Science.gov (United States)

    Garelnabi, Mahdi; Litvinov, Dmitry; Parthasarathy, Sampath

    2010-09-01

    Azelaic acid (AzA) is the best known dicarboxilic acid to have pharmaceutical benefits and clinical applications and also to be associated with some diseases pathophysiology. We extracted and methylesterified AzA and determined its concentration in human plasma obtained from healthy individuals and also in mice fed AzA containing diet for three months. AzA was detected in Gas Chromatography (GC) and confirmed by Liquid chromatography mass spectrometry (LCMS), and gas chromatography mass spectrometry (GCMC). Our results have shown that AzA can be determined efficiently in selected biological samples by GC method with 1nM limit of detection (LoD) and the limit of quantification (LoQ); was established at 50nM. Analytical Sensitivity as assayed by hexane demonstrated an analytical sensitivity at 0.050nM. The method has demonstrated 8-10% CV batch repeatability across the sample types and 13-18.9% CV for the Within-Lab Precision analysis. The method has shown that AzA can efficiently be recovered from various sample preparation including liver tissue homogenate (95%) and human plasma (97%). Because of its simplicity and lower limit of quantification, the present method provides a useful tool for determining AzA in various biological sample preparations.

  6. Measurement of vapor pressure of organophosphorous compounds by gas chromatography

    International Nuclear Information System (INIS)

    Panneerselvam, K.; Brahmmananda Rao, C.V.S.; Antony, M.P.

    2016-01-01

    Dialkylalkyl phosphonates have been developed as an alternative solvent to TBP at our laboratory for separation of actinides. Several dialkylalkylphosphonates have been synthesized and the vapor pressure of all of them was determined using Gas Chromatography (GC) technique. In this technique, individual dialkylalkylphosphonates have been separated from a mixture using GC. Gas chromatography has been utilized as a successful technique in determining vapor pressure of homologous series and structurally similar compounds. GC retention time (t a ) is inversely proportional to the vapor pressure of the solute in solution of the stationary phase. This technique strongly depends on the linear correlation observed between 1n(p/p 0 ) of a reference compound and a target sample under investigation, where p is the vapor pressure for reference compound, p 0 = 101.325 kPa, and 1n(t 0 /t a ) where t 0 = 1 minute and t a = difference in retention times of the target compound and a nonretained compound, CH 2 Cl 2 , added. The retention time of reference (trialkyl phosphate) and target (dibutylalkyl phosphonates) compounds along with CH 2 Cl 2 has been obtained by gas chromatograph using a 4 m 10 % XE-60 packed column under isothermal conditions. Helium was used as carrier gas. As expected, the vapor pressure of reference as well as target compounds decreases with increasing molecular weight of organophosphorous compounds. The merits of this technique are its speed, accuracy and tiny volume of sample. Requirement of high purity sample in contrast to the conventional technique is also done away with this technique. (author)

  7. Gas chromatography-olfactometry analysis of the volatile compounds of two commercial Irish beef meats

    NARCIS (Netherlands)

    Machiels, D.; Ruth, van S.M.; Posthumus, M.A.; Istasse, L.

    2003-01-01

    The volatile flavour compounds of two commercial Irish beef meats (labelled as conventional and organic) were evaluated by gas chromatography-olfactometry and were identified by gas chromatography-mass spectrometry. The volatile compounds were isolated in a model mouth system. Gas

  8. Characterization of crude oils and petroleum products: (I) Elution liquid chromatographic separation and gas chromatographic analysis of crude oils and petroleum products

    OpenAIRE

    E.O. Odebunmi; E.A. Ogunsakin; P.E.P. Ilukhor

    2002-01-01

    Some physical and chemical properties of samples of light, medium and heavy Nigerian crude oils and petroleum products including gasoline, kerosene and engine oil have been measured and are reported in this paper. The crude oils and petroleum products have also been characterized by fractional distillation and elution liquid chromatography. The fractions obtained from elution liquid chromatography were analyzed using gas chromatography (GC). The GC fractions were identified by comparing the r...

  9. [Compound preservative and cyclamat determinated by gas chromatography].

    Science.gov (United States)

    Xin, Ruozhu; Ding, Mei; Zheng, Xianguang; Li, Yajuan

    2008-07-01

    To establish a gas chromatography method for synchronous determination of six preservatives and cyclamat in cake and pastry. The pre-treatment of complicated compound was finished by dialysis cleaning technology. The interference of the complicated foundation body in the cake and pastry was removed by the best dialysis condition: 2 g/L NaOH of dialysis fluid was dialyzed at the temperature of 25 degrees C for 24h, and the six preservatives and cyclamat (sorbic acid, benzoic acid, dehydroacetic acid, ethylparabenum, propylparabenum, butylparabenun and sodium cyclamate) were synchronously seperated by 60-80 mesh Chromosorb WAW DMCS glass packing column of intercoated 5% DEGS + 1% H3 PO4. The seven components in the sample had a good lining relation at the concentration 100 -5000 mg/L when the external standard method was used, and their correlation coefficients were 0.9993-0.9998, and their average recovery rates were 87.5%-101.9%, and their relative standard deviations were 0.64%-3.3%, and detection limits were 1.1-8.8 mg/L. This method could be used to quickly analyse the compound preservatives of the large batch cake and pastry through the common gas chromatography and packed column and this method was simple, accurate and quick.

  10. Detecting naphthenic acids in waters by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Merlin, Mireya; Guigard, Selma E; Fedorak, Phillip M

    2007-01-26

    Naphthenic acids (general formula C(n)H(2n+Z)O(2)) are water-soluble, toxic compounds found in petroleum and bitumen. Some of the current methods for detecting these acids in waters depend on measuring the presence of the carboxylic acid functional group, and therefore many of these methods also detect naturally occurring carboxylic acids that are not naphthenic acids. We report a procedure that includes liquid-liquid extraction, cleanup, and derivatization to form t-butyldimethylsilyl esters prior to gas chromatography-mass spectrometry (GC-MS) analysis. Using low- and high-resolution MS to detect the ion C(15)H(27)O(2)Si(+) (nominal m/z=267) is an excellent indicator of the presence of naphthenic acids at concentrations > or =10microgL(-1).

  11. Liquid chromatography-mass spectrometry in forensic toxicology.

    Science.gov (United States)

    Van Bocxlaer, J F; Clauwaert, K M; Lambert, W E; Deforce, D L; Van den Eeckhout, E G; De Leenheer, A P

    2000-01-01

    Liquid chromatography-mass spectrometry has evolved from a topic of mainly research interest into a routinely usable tool in various application fields. With the advent of new ionization approaches, especially atmospheric pressure, the technique has established itself firmly in many areas of research. Although many applications prove that LC-MS is a valuable complementary analytical tool to GC-MS and has the potential to largely extend the application field of mass spectrometry to hitherto "MS-phobic" molecules, we must recognize that the use of LC-MS in forensic toxicology remains relatively rare. This rarity is all the more surprising because forensic toxicologists find themselves often confronted with the daunting task of actually searching for evidence materials on a scientific basis without any indication of the direction in which to search. Through the years, mass spectrometry, mainly in the GC-MS form, has gained a leading role in the way such quandaries are tackled. The advent of robust, bioanalytically compatible combinations of liquid chromatographic separation with mass spectrometric detection really opens new perspectives in terms of mass spectrometric identification of difficult molecules (e.g., polar metabolites) or biopolymers with toxicological relevance, high throughput, and versatility. Of course, analytical toxicologists are generally mass spectrometry users rather than mass spectrometrists, and this difference certainly explains the slow start of LC-MS in this field. Nevertheless, some valuable applications have been published, and it seems that the introduction of the more universal atmospheric pressure ionization interfaces really has boosted interests. This review presents an overview of what has been realized in forensic toxicological LC-MS. After a short introduction into LC-MS interfacing operational characteristics (or limitations), it covers applications that range from illicit drugs to often abused prescription medicines and some

  12. Confirmatory analysis of acetylgestagens in plasma using liquid chromatography-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Mortensen, Sarah Kelly; Pedersen, Mikael

    2007-01-01

    -assisted liquid-liquid extraction (LLE) on Extrelut NT columns followed by C18 solid-phase extraction (SPE). Analytes were analysed using liquid chromatography-tandem mass spectrometry (I-C-MS/MS), and quantification was performed using matrix-matched calibration standards in combination with deuterated internal...

  13. Measurement of activity coefficients of mixtures by head-space gas chromatography: general procedure.

    Science.gov (United States)

    Luis, Patricia; Wouters, Christine; Van der Bruggen, Bart; Sandler, Stanley I

    2013-08-09

    Head-space gas chromatography (HS-GC) is an applicable method to perform vapor-liquid equilibrium measurements and determine activity coefficients. However, the reproducibility of the data may be conditioned by the experimental procedure concerning to the automated pressure-balanced system. The study developed in this work shows that a minimum volume of liquid in the vial is necessary to ensure the reliability of the activity coefficients since it may become a parameter that influences the magnitude of the peak areas: the helium introduced during the pressurization step may produce significant variations of the results when too small volume of liquid is selected. The minimum volume required should thus be evaluated prior to obtain experimentally the concentration in the vapor phase and the activity coefficients. In this work, the mixture acetonitrile-toluene is taken as example, requiring a sample volume of more than 5mL (about more than 25% of the vial volume). The vapor-liquid equilibrium and activity coefficients of mixtures at different concentrations (0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8, 0.9 molar fraction) and four temperatures (35, 45, 55 and 70°C) have been determined. Relative standard deviations (RSD) lower than 5% have been obtained, indicating the good reproducibility of the method when a sample volume larger than 5mL is used. Finally, a general procedure to measure activity coefficients by means of pressure-balanced head-space gas chromatography is proposed. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Gas To Liquids Technology: A Futuristic View

    International Nuclear Information System (INIS)

    El Shamy, A.A; Zayed, A.M

    2004-01-01

    Worldwide efforts aimed to the formulation of environment friendly diesel fuels able to meet the advanced fuel specifications of the 21 st century and able to meet the global demand on diesel fuels. Synthetically derived gas to-liquid (GTL) diesel fuel promises to meet these challenges and spearhead the way to the future. This technology will produce almost zero sulfur, high cetane, low aromatic diesel and naphtha which will be sold regionally and internationally. GTL fuel is cleaner than any conventional fuel which will help the environment. It can be used in conventional diesel engines to give reductions in emission levels. Construction of such technology will reduce the gap between production and consumption by maximizing the gross profitability of natural gas

  15. Gas-to-liquids : who cares?

    International Nuclear Information System (INIS)

    Yakobson, D.L.

    1999-01-01

    An overview of gas-to-liquids (GTL) technology was presented along with its capital costs, economics and market niche. GTL technology is a process developed by Fischer-Tropsch in the 1920s, in which carbonaceous feedstock is catalytically converted into synthetic oil. The feedstock can be natural gas, coal, or refinery bottoms, bitumen, Orimulsion TM or biomass. The process involves the making of a gaseous mixture of hydrogen and carbon monoxide and then feeding that mixture into a reactor containing a catalyst. The last step involves the processing of the synthetic oil into fractions for sale. The issue of whether GTL will compete with refinery production or supplement it was also raised. The potential for GTL projects in North America were reviewed. The five companies which have matured GTL technologies are Exxon, Rentech, Sasol, Shell and Syntroleum

  16. Generation of Local Concentration Gradients by Gas-Liquid Contacting

    NARCIS (Netherlands)

    de Jong, J.; Verheijden, Pascal W.; Lammertink, Rob G.H.; Wessling, Matthias

    2008-01-01

    We present a generic concept to create local concentration gradients, based on the absorption of gases or vapors in a liquid. A multilayer microfluidic device with crossing gas and liquid channels is fabricated by micromilling and used to generate multiple gas-liquid contacting regions, separated by

  17. Chlorococcalean microalgae Ankistrodesmus convolutes biodiesel characterization with Fourier transform-infrared spectroscopy and gas chromatography mass spectroscopy techniques

    Directory of Open Access Journals (Sweden)

    Swati SONAWANE

    2015-12-01

    Full Text Available The Chlorococcalean microalgae Ankistrodesmus convolutes was found in fresh water Godawari reservoir, Ahmednagar district of Maharashtra State, India. Microalgae are modern biomass for the production of liquid biofuel due to its high solar cultivation efficiency. The collection, harvesting and drying processes were play vital role in converting algal biomass into energy liquid fuel. The oil extraction was the important step for the biodiesel synthesis. The fatty acid methyl ester (FAME synthesis was carried through base catalyzed transesterification method. The product was analyzed by using the hyphened techniques like Fourier Transform-Infrared spectroscopy (FT-IR and Gas Chromatography Mass Spectroscopy (GCMS. FT-IR Spectroscopy was results the ester as functional group of obtained product while the Gas Chromatography Mass Spectroscopy was results the six type of fatty acid methyl ester with different concentration. Ankistrodesmus convolutes biodiesel consist of 46.5% saturated and 49.14% unsaturated FAME.

  18. Investigation of Symphytum cordatum alkaloids by liquid-liquid partitioning, thin-layer chromatography and liquid chromatography-ion-trap mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Mroczek, Tomasz [Department of Pharmacognosy with Medicinal Plants Laboratory, Medical University, 1 Chodzki St., 20-093 Lublin (Poland)]. E-mail: tmroczek@pharmacognosy.org; Ndjoko-Ioset, Karine [Laboratoire de Pharmacognosie et Phytochimie, Ecole de Pharmacie Geneve-Lausanne, Universite de Geneve, Quai Ernest-Ansermet 30, CH-1211 Geneva 4 (Switzerland); Glowniak, Kazimierz [Department of Pharmacognosy with Medicinal Plants Laboratory, Medical University, 1 Chodzki St., 20-093 Lublin (Poland); Mietkiewicz-Capala, Agnieszka [Department of Pharmacognosy with Medicinal Plants Laboratory, Medical University, 1 Chodzki St., 20-093 Lublin (Poland); Hostettmann, Kurt [Laboratoire de Pharmacognosie et Phytochimie, Ecole de Pharmacie Geneve-Lausanne, Universite de Geneve, Quai Ernest-Ansermet 30, CH-1211 Geneva 4 (Switzerland)

    2006-05-04

    From the alkalised crude extract of Symphytum cordatum (L.) W.K. roots, pyrrolizidine alkaloids (PAs) were extracted as free tertiary bases and polar N-oxides in a merely one-step liquid-liquid partitioning (LLP) in separation funnel and subsequently pre-fractionated by preparative multiple-development (MD) thin-layer chromatography (TLC) on silica gel plates. In this way three alkaloid fractions of different polarities and retention on silica gel plates were obtained as: the most polar N-oxides of the highest retention, the tertiary bases of medium retention, and diesterified N-oxides of the lowest retention. The former fraction was reduced into free bases by sodium hydrosulfite and purified by LLP on Extrelut-NT3 cartridge. It was further analysed together with the two other fractions by high-performance liquid chromatography (HPLC)-ion-trap mass spectrometry with atmospheric pressure chemical ionization (APCI) interface on XTerra C{sub 18} column using a gradient elution. Based on MS {sup n} spectra, 18 various alkaloids have been tentatively determined for the first time in this plant as the following types of structure: echimidine-N-oxide (three diasteroisomers), 7-sarracinyl-9-viridiflorylretronecine (two diasteroisomers), echimidine (two diasteroisomers), lycopsamine (two diasteroisomers), dihydroechinatine-N-oxide, dihydroheliospathuline-N-oxide, lycopsamine-N-oxide (three diasteroisomers), 7-acetyllycopsamine-N-oxide, symphytine-N-oxide (two diasteroisomers) and 2'',3''-epoxyechiumine-N-oxide.

  19. Investigation of Symphytum cordatum alkaloids by liquid-liquid partitioning, thin-layer chromatography and liquid chromatography-ion-trap mass spectrometry

    International Nuclear Information System (INIS)

    Mroczek, Tomasz; Ndjoko-Ioset, Karine; Glowniak, Kazimierz; Mietkiewicz-Capala, Agnieszka; Hostettmann, Kurt

    2006-01-01

    From the alkalised crude extract of Symphytum cordatum (L.) W.K. roots, pyrrolizidine alkaloids (PAs) were extracted as free tertiary bases and polar N-oxides in a merely one-step liquid-liquid partitioning (LLP) in separation funnel and subsequently pre-fractionated by preparative multiple-development (MD) thin-layer chromatography (TLC) on silica gel plates. In this way three alkaloid fractions of different polarities and retention on silica gel plates were obtained as: the most polar N-oxides of the highest retention, the tertiary bases of medium retention, and diesterified N-oxides of the lowest retention. The former fraction was reduced into free bases by sodium hydrosulfite and purified by LLP on Extrelut-NT3 cartridge. It was further analysed together with the two other fractions by high-performance liquid chromatography (HPLC)-ion-trap mass spectrometry with atmospheric pressure chemical ionization (APCI) interface on XTerra C 18 column using a gradient elution. Based on MS n spectra, 18 various alkaloids have been tentatively determined for the first time in this plant as the following types of structure: echimidine-N-oxide (three diasteroisomers), 7-sarracinyl-9-viridiflorylretronecine (two diasteroisomers), echimidine (two diasteroisomers), lycopsamine (two diasteroisomers), dihydroechinatine-N-oxide, dihydroheliospathuline-N-oxide, lycopsamine-N-oxide (three diasteroisomers), 7-acetyllycopsamine-N-oxide, symphytine-N-oxide (two diasteroisomers) and 2'',3''-epoxyechiumine-N-oxide

  20. Liquid-liquid extraction and liquid chromatography-mass spectrometry detection of curcuminoids from bacterial culture medium.

    Science.gov (United States)

    Tan, Suryani; Rupasinghe, Thusitha W T; Tull, Dedreia L; Augustin, Mary Ann; Gras, Sally L

    2015-04-15

    Liquid chromatography-mass spectrometry (LC-MS) has been used to detect polyphenolic curcuminoids found in turmeric but studies of metabolism by bacterial and mammalian cells in vitro are compromised by poor recovery from the culture medium. We report a liquid-liquid extraction procedure with ethyl acetate and use LC-MS to quantify extracted curcuminoids. Ethyl acetate allows recoveries of ∼ 80-86% of curcuminoids from the bacterial growth medium, bacterial cell lysate and combined bacterial cell and growth medium matrices; a clear improvement over acetonitrile where recoveries were ∼ 25-66%. This optimised method will enable studies of curcuminoid metabolism and may be applicable to other hydrophobic polyphenolic compounds. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Rapid Identification of Airborne Biological Particles by Flow Cytometry, Gas Chromatography, and Genetic Probes

    National Research Council Canada - National Science Library

    Wick, Charles

    1997-01-01

    .... Physical characteristics of the particles, it was proposed, could be detected by flow cytometry, while their biochemical profiles could be determined by gas chromatography, and their genetic identity...

  2. U.S. crude oil, natural gas, and natural gas liquids reserves 1997 annual report

    Energy Technology Data Exchange (ETDEWEB)

    Wood, John H.; Grape, Steven G.; Green, Rhonda S.

    1998-12-01

    This report presents estimates of proved reserves of crude oil, natural gas, and natural gas liquids as of December 31, 1997, as well as production volumes for the US and selected States and State subdivisions for the year 1997. Estimates are presented for the following four categories of natural gas: total gas (wet after lease separation), nonassociated gas and associated-dissolved gas (which are the two major types of wet natural gas), and total dry gas (wet gas adjusted for the removal of liquids at natural gas processing plants). In addition, reserve estimates for two types of natural gas liquids, lease condensate and natural gas plant liquids, are presented. Also included is information on indicated additional crude oil reserves and crude oil, natural gas, and lease condensate reserves in nonproducing reservoirs. A discussion of notable oil and gas exploration and development activities during 1997 is provided. 21 figs., 16 tabs.

  3. Characterization of the fermentation process by gas chromatography Lasiodiplodia theobromae and gas chromatography coupled with mass spectrometry

    International Nuclear Information System (INIS)

    Castillo Portela, Grolamys; Eng Sanchez, Felipe; Nogueiras Lima, Clara

    2014-01-01

    Lasiodiplodia theobromae is a fungus, which has been reported by some authors as a high yield producer of the phytohormone jasmonic acid (JA). An indigenous strain of this fungus has been used for producing a fermentation broth with a high JA concentration by the Cuban Research Institute for Sugar Cane Derivatives (ICIDCA), registered as BIOJAS. The broth has been applied to some agricultural crops and demonstrated its economic feasibility as plant growth regulator and biological control of various phytopathogenic microorganisms and pests. Both fermentation broth and biomass from this fungus contain some other metabolites having bioactive properties, for instance, fatty acids. This paper shows the composition and quantification of fatty acids in the biomass using Gas Chromatography (GC) and the identification of substances profile in fermentation broth by Gas Chromatography coupled to Mass Spectrometry (GC-MS). The most fatty acids in the biomass are palmitic, stearic, oleic, linoleic and linolenic acids, being oleic acid the major component. On the other hand, 2,32 % of fatty acid esters; 2,47 % of alkenes; 14,40 % of alcohols; 30,15 % of aldehydes and 21,73 % of paraffins were detected in the composition of fermentation broth

  4. Liquid oil production from shale gas condensate reservoirs

    Energy Technology Data Exchange (ETDEWEB)

    Sheng, James J.

    2018-04-03

    A process of producing liquid oil from shale gas condensate reservoirs and, more particularly, to increase liquid oil production by huff-n-puff in shale gas condensate reservoirs. The process includes performing a huff-n-puff gas injection mode and flowing the bottom-hole pressure lower than the dew point pressure.

  5. Electrochemically modulated liquid chromatography: Theoretical investigations and applications from the perspectives of chromatography and interfacial electrochemistry

    Energy Technology Data Exchange (ETDEWEB)

    Keller, David W. [Iowa State Univ., Ames, IA (United States)

    2005-01-01

    Electrochemically modulated liquid chromatography (EMLC) employs a conductive material as both a stationary phase for chromatographic separations and as a working electrode for performing electrochemistry experiments. This dual functionality gives EMLC the capacity to manipulate chromatographic separations by changing the potential applied (Eapp) to the stationary phase with respect to an external reference. The ability to monitor retention as a function of Eapp provides a means to chromatographically monitor electrosorption processes at solid-liquid interfaces. In this dissertation, the retention mechanism for EMLC is examined from the perspective of electrical double layer theory and interfacial thermodynamics. From the chromatographic data, it is possible to determine the interfacial excess (Λ) of a solute and changes in interfacial tension (dγ) as a function of both Eapp and the supporting electrolyte concentration. Taken together, these two experimentally manipulated parameters can be examined within the context of the Gibbs adsorption equation to delineate the contribution of a variety of interfacial properties, including the charge of solute on the stationary phase and the potential of zero charge (PZC), to the mechanism behind EMLC-based retention. The chromatographic probing of interfacial phenomena is complemented by electroanalytical experiments that exploit the ability to monitor the electronic current flowing through an EMLC column. Cyclic voltammetry and chronoamperometry of an EMLC column are used to determine the electronic performance characteristics of an EMLC column. An electrochemical flow injection analysis of a column is provided in which the current required to maintain a constant Eapp is monitored and provides a way to examine the influence that acetonitrile and supporting electrolyte composition, flow rate, column backpressure, and ionic strength have on the structure of electrified interfaces.

  6. Determination of triazine herbicides in juice samples by microwave-assisted ionic liquid/ionic liquid dispersive liquid-liquid microextraction coupled with high-performance liquid chromatography.

    Science.gov (United States)

    Su, Rui; Li, Dan; Wu, Lijie; Han, Jing; Lian, Wenhui; Wang, Keren; Yang, Hongmei

    2017-07-01

    A novel microextraction method, termed microwave-assisted ionic liquid/ionic liquid dispersive liquid-liquid microextraction, has been developed for the rapid enrichment and analysis of triazine herbicides in fruit juice samples by high-performance liquid chromatography. Instead of using hazardous organic solvents, two kinds of ionic liquids, a hydrophobic ionic liquid (1-hexyl-3-methylimidazolium hexafluorophosphate) and a hydrophilic ionic liquid (1-butyl-3-methylimidazolium tetrafluoroborate), were used as the extraction solvent and dispersion agent, respectively, in this method. The extraction procedure was induced by the formation of cloudy solution, which was composed of fine drops of 1-hexyl-3-methylimidazolium hexafluorophosphate dispersed entirely into sample solution with the help of 1-butyl-3-methylimidazolium tetrafluoroborate. In addition, an ion-pairing agent (NH 4 PF 6 ) was introduced to improve recoveries of the ionic liquid phase. Several experimental parameters that might affect the extraction efficiency were investigated. Under the optimum experimental conditions, the linearity for determining the analytes was in the range of 5.00-250.00 μg/L, with the correlation coefficients of 0.9982-0.9997. The practical application of this effective and green method is demonstrated by the successful analysis of triazine herbicides in four juice samples, with satisfactory recoveries (76.7-105.7%) and relative standard deviations (lower than 6.6%). In general, this method is fast, effective, and robust to determine triazine herbicides in juice samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Separation of krypton from dissolver off-gas of a reprocessing plant using preparative gas chromatography

    International Nuclear Information System (INIS)

    Matoni, M.

    1984-02-01

    Kr-85 can be separated from the pre-purified purge air in the final processing step of the purification phase for dissolver off-gases of a reprocessing plant with the aid of preparative gas chromatography. Activated carbon adsorbers in combination with helium as carrier gas permits maximum gas mixture through-flow. A separation temperature of 30 0 C is considered optimal. An adsorbent volume of 40 dm 3 is necessary for processing the residual gas flow of 2.5 Nm 3 /h; the adsorbent is divided between 2 columns linked in series each of which are 2 m long with an internal diameter of 100 mm. The helium flow required is five times greater than the off-gas flow. The degree of purity for krypton is greater than 90% for a decontamination factor of greater than 1000. (orig./HP) [de

  8. Column liquid chromatography-ultraviolet and column liquid chromatography/mass spectrometry evaluation of stress degradation behavior of escitalopram oxalate.

    Science.gov (United States)

    Dhaneshwar, Sunil R; Mahadik, Mahadeo V; Kulkarni, Mahesh J

    2009-01-01

    The objective of this work was to study the degradation behavior of escitalopram oxalate under different International Conference on Harmonization (ICH)-recommended stress conditions by column liquid chromatography (LC)-UV and LC/mass spectrometry (LC/MS) and to establish a validated stability-indicating LC assay method. Escitalopram oxalate was subjected to stress conditions of hydrolysis, oxidation, photolysis, and thermal decomposition. Extensive degradation was found to occur in alkaline medium. Mild degradation was observed in acidic and oxidative conditions. Escitalopram oxalate was stable to neutral, photolytic, and thermal stress. Successful separation of the drug from degradation products formed under stress conditions was achieved on a PerfectSil-100 ODS-3 column [C18 (5 microm, 25 cm x 4.6 mm id)] using methanol-0.01 M acetate buffer pH 3.8 adjusted with acetic acid (45 + 55) as the mobile phase. The flow rate was 1 ml/min, and the detection wavelength was 239 nm. The method was validated according to ICH guidelines. Major degradation products formed in hydrolysis and oxidative conditions were isolated, and structural elucidation of degradation products was done by LCIMS and infrared spectrometry studies. The major hydrolysis degradation product was confirmed as 1-(3-dimethylaminopropyl)-1-(4-fluoro- phenyl)-1,3dihydroisobenzofuran-5-carboxylic acid, and the major oxidative degradation product was confirmed as 1-{[3-dimethylamino(oxide)- propyl]-1-(4-fluro-phenyl)}-1,3-dihydro-isobenzofuran- 5-carbonitrile.

  9. Liquid chromatography-fluorescence and liquid chromatography-mass spectrometry detection of tryptophan degradation products of a recombinant monoclonal antibody.

    Science.gov (United States)

    Nowak, Christine; Ponniah, Gomathinayagam; Cheng, Guilong; Kita, Adriana; Neill, Alyssa; Kori, Yekaterina; Liu, Hongcheng

    2016-03-01

    Light exposure is one of several conditions used to study the degradation pathways of recombinant monoclonal antibodies. Tryptophan is of particular interest among the 20 amino acids because it is the most photosensitive. Tryptophan degradation forms several products, including an even stronger photosensitizer and several reactive oxygen species. The current study reports a specific peptide mapping procedure to monitor tryptophan degradation. Instead of monitoring peptides using UV 214 nm, fluorescence detection with an excitation wavelength of 295 nm and an emission wavelength of 350 nm was used to enable specific detection of tryptophan-containing peptides. Peaks that decreased in area over time are likely to contain susceptible tryptophan residues. This observation can allow further liquid chromatography-mass spectrometry (LC-MS) analysis to focus only on those peaks to confirm tryptophan degradation products. After confirmation of tryptophan degradation, susceptibility of tryptophan residues can be compared based on the peak area decrease. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Chemical discrimination in turbulent gas mixtures with MOX sensors validated by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Fonollosa, Jordi; Rodríguez-Luján, Irene; Trincavelli, Marco; Vergara, Alexander; Huerta, Ramón

    2014-10-16

    Chemical detection systems based on chemo-resistive sensors usually include a gas chamber to control the sample air flow and to minimize turbulence. However, such a kind of experimental setup does not reproduce the gas concentration fluctuations observed in natural environments and destroys the spatio-temporal information contained in gas plumes. Aiming at reproducing more realistic environments, we utilize a wind tunnel with two independent gas sources that get naturally mixed along a turbulent flow. For the first time, chemo-resistive gas sensors are exposed to dynamic gas mixtures generated with several concentration levels at the sources. Moreover, the ground truth of gas concentrations at the sensor location was estimated by means of gas chromatography-mass spectrometry. We used a support vector machine as a tool to show that chemo-resistive transduction can be utilized to reliably identify chemical components in dynamic turbulent mixtures, as long as sufficient gas concentration coverage is used. We show that in open sampling systems, training the classifiers only on high concentrations of gases produces less effective classification and that it is important to calibrate the classification method with data at low gas concentrations to achieve optimal performance.

  11. LIQUID NATURAL GAS (LNG): AN ALTERNATIVE FUEL FROM LANDFILL GAS (LFG) AND WASTEWATER DIGESTER GAS

    Energy Technology Data Exchange (ETDEWEB)

    VANDOR,D.

    1999-03-01

    This Research and Development Subcontract sought to find economic, technical and policy links between methane recovery at landfill and wastewater treatment sites in New York and Maryland, and ways to use that methane as an alternative fuel--compressed natural gas (CNG) or liquid natural gas (LNG) -- in centrally fueled Alternative Fueled Vehicles (AFVs).

  12. Determination of three natural pesticides in processed fruit and vegetables using high-performance liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Sannino, Anna

    2007-01-01

    This paper describes a method for the sensitive and selective determination of two macrocyclic lactones (abamectin and spinosad) and azadirachtin in apple purée, concentrated lemon juice, tomato purée and canned peas. The general sample extraction-partitioning method for our gas chromatography and liquid chromatography multiresidue methods has been used. The analytical procedure involves an extraction with acetone and liquid-liquid partitioning with ethyl acetate/cyclohexane combined in one step. The extracts are analyzed by liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) without any further clean-up step. The pesticides are separated on a reversed-phase C12 column using a gradient elution. Thirteen simultaneous MS/MS transitions of precursor ions were monitored. Studies at fortification levels of 2.5-10 microg/kg and 25-100 microg/kg gave mean recoveries ranging from 70-100% for all compounds with satisfactory precision (relative standard deviation (RSD) from 3-20%). The excellent selectivity and sensitivity allows quantification and identification of low levels of pesticides in canned peas, tomato and apple purées (limits of quantitation (LOQs) 1-5 microg/kg) and in concentrated lemon juice (LOQs 2-10 microg/kg). The quantification of analytes was carried out using the most sensitive transition for every compound and by 'matrix-matched' standards calibration. Copyright (c) 2007 John Wiley & Sons, Ltd.

  13. Urinary detection of conjugated and unconjugated anabolic steroids by dilute-and-shoot liquid chromatography-high resolution mass spectrometry.

    Science.gov (United States)

    Tudela, Eva; Deventer, Koen; Geldof, Lore; Van Eenoo, Peter

    2015-02-01

    Anabolic androgenic steroids (AAS) are an important class of doping agents. The metabolism of these substances is generally very extensive and includes phase-I and phase-II pathways. In this work, a comprehensive detection of these metabolites is described using a 2-fold dilution of urine and subsequent analysis by liquid chromatography-high resolution mass spectrometry (LC-HRMS). The method was applied to study 32 different metabolites, excreted free or conjugated (glucuronide or sulfate), which permit the detection of misuse of at least 21 anabolic steroids. The method has been fully validated for 21 target compounds (8 glucuronide, 1 sulfate and 12 free steroids) and 18 out of 21 compounds had detection limits in the range of 1-10 ng mL(-1) in urine. For the conjugated compounds, for which no reference standards are available, metabolites were synthesized in vitro or excretion studies were investigated. The detection limits for these compounds ranged between 0.5 and 18 ng mL(-1) in urine. The simple and straightforward methodology complements the traditional methods based on hydrolysis, liquid-liquid extraction, derivatization and analysis by gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-mass spectrometry (LC-MS). Copyright © 2014 John Wiley & Sons, Ltd.

  14. Determination of maduramicin in feedingstuffs and premixtures by liquid chromatography : development, validation and interlaboratory study

    NARCIS (Netherlands)

    Jong, de J.; Stoisser, B.; Wagner, K.; Tomassen, M.J.H.; Driessen, J.J.M.; Hofman, P.; Putzka, H.A.

    2004-01-01

    A reversed-phase liquid chromatography method for determination of maduramicin in feedingstuffs and premixtures was developed, validated, and interlaboratory studied. The extraction solvent was methanol. Maduramicin was detected at 520 nm after postcolumn derivatization with vanillin. Recovery was

  15. Determination of Aspartame, Caffeine, Saccharin, and Benzoic Acid in Beverages by High Performance Liquid Chromatography.

    Science.gov (United States)

    Delaney, Michael F.; And Others

    1985-01-01

    Describes a simple and reliable new quantitative analysis experiment using liquid chromatography for the determinaiton of caffeine, saccharin, and sodium benzoate in beverages. Background information, procedures used, and typical results obtained are provided. (JN)

  16. Assay for dihydroorotase using high-performance liquid chromatography with radioactivity detection

    International Nuclear Information System (INIS)

    Mehdi, S.; Wiseman, J.S.

    1989-01-01

    An assay for measuring dihydroorotase activity was devised. Radiolabeled substrate and product were separated by high-performance liquid chromatography using a reverse-phase column with ion-pairing, and the radioactivity was quantitated by flow detection

  17. Qualitative and quantitative determination of ubiquinones by the method of high-efficiency liquid chromatography

    International Nuclear Information System (INIS)

    Yanotovskii, M.T.; Mogilevskaya, M.P.; Obol'nikova, E.A.; Kogan, L.M.; Samokhvalov, G.I.

    1986-01-01

    A method has been developed for the qualitative and quantitative determination of ubiquinones CoQ 6 -CoQ 10 , using high-efficiency reversed-phase liquid chromatography. Tocopherol acetate was used as the internal standard

  18. Two-dimensional liquid chromatography and its application in traditional Chinese medicine analysis and metabonomic investigation.

    Science.gov (United States)

    Li, Zheng; Chen, Kai; Guo, Meng-zhe; Tang, Dao-quan

    2016-01-01

    Two-dimensional liquid chromatography has become an attractive analytical tool for the separation of complex samples due to its enhanced selectivity, peak capacity, and resolution compared with one-dimensional liquid chromatography. Recently, more attention has been drawn on the application of this separation technique in studies concerning traditional Chinese medicines, metabonomes, proteomes, and other complex mixtures. In this review, we aim to examine the application of two-dimensional liquid chromatography in traditional Chinese medicine analysis and metabonomic investigation. The classification and evaluation indexes were first introduced. Then, various switching methods were summarized when used in an on-line two-dimensional liquid chromatography system. Finally, the applications of this separation technique in traditional Chinese medicine analysis and metabonomic investigation were discussed on the basis of specific studies. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Off-line mixed-mode liquid chromatography coupled with reversed phase high performance liquid chromatography-high resolution mass spectrometry to improve coverage in lipidomics analysis.

    Science.gov (United States)

    Narváez-Rivas, Mónica; Vu, Ngoc; Chen, Guan-Yuan; Zhang, Qibin

    2017-02-15

    The confident identification and in-depth profiling of molecular lipid species remain to be a challenge in lipidomics analysis. In this work, an off-line two-dimensional mixed-mode and reversed-phase liquid chromatography (RPLC) method combined with high-field quadrupole orbitrap mass spectrometer (Q Exactive HF) was developed to profile lipids from complex biological samples. In the first dimension, 22 different lipid classes were separated on a monolithic silica column with elution order from neutral to polar lipids. A total of 13 fractions were collected and run on a RPLC C30 column in the second dimension for further separation of the lipid molecular species based on their hydrophobicity, with the elution order being determined by both the length and degree of unsaturation in the fatty-acyl chain. The method was applied to analyze lipids extracted from rat plasma and rat liver. Fatty acid methyl ester analysis by gas chromatography-mass spectrometry was used to identify the fatty acyls from total lipid extracts, which provided a more confident identification of the lipid species present in these samples. More than 800 lipids were identified in each sample and their molecular structures were confidentially confirmed using tandem mass spectrometry (MS/MS). The number of lipid molecular species identified in both rat plasma and rat liver by this off-line two-dimensional method is approximately twice of that by one-dimensional RPLC-MS/MS employing a C30 column. This off-line two-dimensional mixed-mode LC-RPLC-MS/MS method is a promising technique for comprehensive lipid profiling in complex biological matrices. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Liquid chromatography-mass spectrometry coupling by the intermediary of a liquid micro chromatography-electro spray interface; Couplage chromatographie liquide-spectrometrie de masse par l`intermediaire d`une interface electrospray-microchromatographie liquide

    Energy Technology Data Exchange (ETDEWEB)

    Gillard Factor, C.

    1996-12-06

    The objective of this work is to realize a liquid chromatography- mass spectrometry coupling by the intermediary of an electro spray interface and the evaluation of performances of tis analytical tool to study pollutants in water, and more particularly pesticides whom maximum admissible concentration in a table water is 0.1{mu}g/l. This study has allowed to bring to the fore the interest of the ionization mode by electro spray in a LC/MS coupling to identify and quantify pesticides in the state of traces without treating the sample. Then, it was demonstrated the usefulness of this analytical tool to detect high molecular masses molecules. (N.C.)

  1. Feedlot lamb meat fatty acids profile characterization employing gas chromatography

    Directory of Open Access Journals (Sweden)

    M.I. Cruz-Gonzalez

    2014-06-01

    Full Text Available Fat is an important constituent in diet, not only as an energy source, but for its essential fatty acids associated to fats in foods, considering that some polyunsaturated fatty acids like linoleic, linolenic and arachidonic cannot be synthesized by superior animals like humans. Scientific evidence show that the fatty acids ingest can affect the thrombotic tendency, cardiac rhythm, endothelial function systematic inflammation, insulin sensibility and oxidative stress. Samples from 21 ovine crossbreds from Pelibuey, Blackbelly, Dorper and Katahadin (40 kg average weight feed with corn based balanced diets were taken from loin area 18 h after refrigeration. Saturated and polyunsaturated fatty acids levels were analyzed by gas chromatography. Results in this work showed that the healthy fatty acids levels are higher as compared to saturated fatty acids levels, indicating that this meat can influence consumer’s buying choice decision regarded to their health.

  2. Selective data reduction in gas chromatography/infrared spectrometry

    International Nuclear Information System (INIS)

    Pyo, Dong Jin; Shin, Hyun Du

    2001-01-01

    As gas chromatography/infrared spectrometry (GC/IR) becomes routinely available, methods must be developed to deal with the large amount of data produced. We demonstrate computer methods that quickly search through a large data file, locating those spectra that display a spectral feature of interest. Based on a modified library search routine, these selective data reduction methods retrieve all or nearly all of the compounds of interest, while rejection the vast majority of unrelated compounds. To overcome the shifting problem of IR spectra, a search method of moving the average pattern was designed. In this moving pattern search, the average pattern of a particular functional group was not held stationary, but was allowed to be moved a little bit right and left

  3. Low thermal mass gas chromatography: principles and applications.

    Science.gov (United States)

    Luong, Jim; Gras, Ronda; Mustacich, Robert; Cortes, Hernan

    2006-01-01

    In gas chromatography (GC), temperature programming is often considered to be the second most important parameter to control, the first being column selectivity. A radically new GC technology to achieve ultrafast temperature programming with an unprecedented cool down time and low power consumption has recently become available. This technology is referred to as low thermal mass GC (LTMGC). Though the technology has its roots in resistive heating, which forms the basis of principle and design concept, the approach taken to achieve ultrafast heating and cool down time by LTMGC represents a significant break-through in GC. Despite some rectifiable shortcomings, LTMGC has proven to be an ideal methodology to deliver near/real time GC data, high precision, and high throughput applications. It is a new approach for modern high-speed GC. This paper documents the fundamental design principles behind LTMGC, performance data, and examples of applications investigated.

  4. Design, testing, and simulation of microscale gas chromatography columns

    Energy Technology Data Exchange (ETDEWEB)

    Hudson, M.L.; Kottenstette, R.; Matzke, C.M.; Frye-Mason, G.C.; Shollenberger, K.A.; Adkins, D.R.; Wong, C.C.

    1998-08-01

    A microscale gas chromatography column is one component in a microscale chemistry laboratory for detecting chemical agents. Several columns were fabricated using the Bosch etch process which allows deep, high aspect ratio channels of rectangular cross-section. A design tool, based on analytical models, was developed to evaluate the effects of operating conditions and column specifications on separation resolution and time. The effects of slip flow, channel configuration, and cross-sectional shape were included to evaluate the differences between conventional round, straight columns and the microscale rectangular, spiral columns. Experimental data were obtained and compared with the predicted flowrates and theoretical number of plates. The design tool was then employed to select more optimum channel dimensions and operating conditions for high resolution separations.

  5. Tryptophan and kynurenine determination in human hair by liquid chromatography.

    Science.gov (United States)

    Dario, Michelli F; Freire, Thamires Batello; Pinto, Claudinéia Aparecida Sales de Oliveira; Prado, María Segunda Aurora; Baby, André R; Velasco, Maria Valéria R

    2017-10-15

    Tryptophan, an amino acid found in hair proteinaceous structure is used as a marker of hair photodegradation. Also, protein loss caused by several chemical/physical treatments can be inferred by tryptophan quantification. Kynurenine is a photo-oxidation product of tryptophan, expected to be detected when hair is exposed mainly to UVB (290-320nm) radiation range. Tryptophan from hair is usually quantified directly as a solid or after alkaline hydrolysis, spectrofluorimetrically. However, these types of measure are not sufficiently specific and present several interfering substances. Thus, this work aimed to propose a quantification method for both tryptophan and kynurenine in hair samples, after alkali hydrolysis process, by using high-performance liquid chromatography (HPLC) with fluorimetric and UV detection. The tryptophan and kynurenine quantification method was developed and validated. Black, white, bleached and dyed (blond and auburn) hair tresses were used in this study. Tryptophan and kynurenine were separated within ∼9min by HPLC. Both black and white virgin hair samples presented similar concentrations of tryptophan, while bleaching caused a reduction in the tryptophan content as well as dyeing process. Unexpectedly, UV/vis radiation did not promote significantly the conversion of tryptophan into its photo-oxidation product and consequently, kynurenine was not detected. Thus, this works presented an acceptable method for quantification of tryptophan and its photooxidation metabolite kynurenine in hair samples. Also, the results indicated that bleaching and dyeing processes promoted protein/amino acids loss but tryptophan is not extensively degraded in human hair by solar radiation. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. An efficient hydrophilic interaction liquid chromatography separation of 7 phospholipid classes based on a diol column

    NARCIS (Netherlands)

    Zhu, C.; Dane, A.; Spijksma, G.; Wang, M.; Greef, J. van der; Luo, G.; Hankemeier, T.; Vreeken, R.J.

    2012-01-01

    A hydrophilic interaction liquid chromatography (HILIC) - ion trap mass spectrometry method was developed for separation of a wide range of phospholipids. A diol column which is often used with normal phase chromatography was adapted to separate different phospholipid classes in HILIC mode using a

  7. Surface-enhanced resonance Raman spectroscopy as an identification tool in column liquid chromatography

    NARCIS (Netherlands)

    Seifar, R.M.; Altelaar, M.A.F.; Dijkstra, R.J.; Ariese, F.; Brinkman, U.A.T.; Gooijer, C.

    2000-01-01

    The compatibility of ion-pair reversed-phase column liquid chromatography and surface-enhanced resonance Raman spectroscopy (SERRS) for separation and identification of anionic dyes has been investigated, with emphasis on the at-line coupling via a thin-layer chromatography (TLC) plate. SERR spectra

  8. US crude oil, natural gas, and natural gas liquids reserves, 1992 annual report

    Energy Technology Data Exchange (ETDEWEB)

    1993-10-18

    This report presents estimates of proved reserves of crude oil, natural gas, and natural gas liquids as of December 31, 1992, as well as production volumes for the United States, and selected States and State subdivisions for the year 1992. Estimates are presented for the following four categories of natural gas: total gas (wet after lease separation), its two major components (nonassociated and associated-dissolved gas), and total dry gas (wet gas adjusted for the removal of liquids at natural gas processing plants). In addition, two components of natural gas liquids, lease condensate and natural gas plant liquids, have their reserves and production data presented. Also included is information on indicated additional crude oil reserves and crude oil, natural gas, and lease condensate reserves in nonproducing reservoirs. A discussion of notable oil and gas exploration and development activities during 1992 is provided.

  9. US crude oil, natural gas, and natural gas liquids reserves, 1992 annual report

    International Nuclear Information System (INIS)

    1993-01-01

    This report presents estimates of proved reserves of crude oil, natural gas, and natural gas liquids as of December 31, 1992, as well as production volumes for the United States, and selected States and State subdivisions for the year 1992. Estimates are presented for the following four categories of natural gas: total gas (wet after lease separation), its two major components (nonassociated and associated-dissolved gas), and total dry gas (wet gas adjusted for the removal of liquids at natural gas processing plants). In addition, two components of natural gas liquids, lease condensate and natural gas plant liquids, have their reserves and production data presented. Also included is information on indicated additional crude oil reserves and crude oil, natural gas, and lease condensate reserves in nonproducing reservoirs. A discussion of notable oil and gas exploration and development activities during 1992 is provided

  10. Development and application of liquid chromatography coupled to isotope ratio mass spectrometry

    International Nuclear Information System (INIS)

    Zhang, Lijun

    2014-01-01

    Stable isotope analysis has found widespread applications in various disciplines such as archaeology, geochemistry, biology, food authenticity, and forensic science. Coupling chromatography to isotope ratio mass spectrometry for compound-specific isotope analysis (CSIA) is a trend, as it provides several advantages over bulk isotope analysis, e.g., relatively simple sample preparation, the ability to measure individual compounds in a complex mixture in one run, and the reduced sample size required for precise isotope analysis. Gas chromatography coupled to isotope ratio mass spectrometry (GC/IRMS) has been well-established for compound-specific isotope analysis of volatile organic compounds within the last two decades. However, an interface combining liquid chromatography with isotope ratio mass spectrometry (LC/IRMS) was not commercially available until 2004. The current design of the interface requires using a carbon-free eluent in chromatographic separation. This requirement limits the application of the most frequently used reversed-phase liquid chromatography in CSIA, because the elution strength of water at room temperature is too low to serve as mobile phase in reversed-phase separations. In order to increase the elution strength of water, we propose using high temperature water for chromatographic elution. The polarity of water decreases with an increase of temperature, yielding increased elution strength in reversed-phase columns. Therefore, high temperature water can be used as eluent instead of organic solvent for combining reversed-phase liquid chromatography with isotope ratio mass spectrometry (RPLC/IRMS). Additionally, temperature gradients can replace organic solvent gradients to increase chromatographic resolution. This is very important for LC/IRMS analysis, as precise isotope analysis requires baseline separation of analytes. In this thesis, high-temperature reversed-phase liquid chromatography was coupled to, and for the first time carefully

  11. Development and application of liquid chromatography coupled to isotope ratio mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Lijun

    2014-02-19

    Stable isotope analysis has found widespread applications in various disciplines such as archaeology, geochemistry, biology, food authenticity, and forensic science. Coupling chromatography to isotope ratio mass spectrometry for compound-specific isotope analysis (CSIA) is a trend, as it provides several advantages over bulk isotope analysis, e.g., relatively simple sample preparation, the ability to measure individual compounds in a complex mixture in one run, and the reduced sample size required for precise isotope analysis. Gas chromatography coupled to isotope ratio mass spectrometry (GC/IRMS) has been well-established for compound-specific isotope analysis of volatile organic compounds within the last two decades. However, an interface combining liquid chromatography with isotope ratio mass spectrometry (LC/IRMS) was not commercially available until 2004. The current design of the interface requires using a carbon-free eluent in chromatographic separation. This requirement limits the application of the most frequently used reversed-phase liquid chromatography in CSIA, because the elution strength of water at room temperature is too low to serve as mobile phase in reversed-phase separations. In order to increase the elution strength of water, we propose using high temperature water for chromatographic elution. The polarity of water decreases with an increase of temperature, yielding increased elution strength in reversed-phase columns. Therefore, high temperature water can be used as eluent instead of organic solvent for combining reversed-phase liquid chromatography with isotope ratio mass spectrometry (RPLC/IRMS). Additionally, temperature gradients can replace organic solvent gradients to increase chromatographic resolution. This is very important for LC/IRMS analysis, as precise isotope analysis requires baseline separation of analytes. In this thesis, high-temperature reversed-phase liquid chromatography was coupled to, and for the first time carefully

  12. Study of high performance liquid chromatography fingerprint for traditional chinese medicine yigongningxue oral liquid

    International Nuclear Information System (INIS)

    Feng, C.; Ruan, J.L.

    2010-01-01

    A simple, reliable and accurate fingerprinting method has been developed for quality control of YiGongNingXue oral liquid. The separation was done by reverse phase chromatography using Zorbax eclipse XDB C/sub 18/ column (250mmx4.6mmi. d. with 5.0 micro m particle size) and detection at 246nm. Methanol (5-95 % in 70 min)-buffer solution (water-phosphorica cid, pH 3.0, 95-0 percent in 70 min) as mobile phase for linear gradient elution. The flow rate was 1.0 mLmin/sup 1/ and the column temperature was at 25 deg. C. The similarity of 20 batches of YGNX oral liquid was more than 90 %. Also 15 common peaks of chromatogram have been detected, ten of them were identified by comparing fingerprint chromatogram with reference substances The HPLC fingerprint can be used to control the quality of YiGongNingXue oral liquid. (author)

  13. Methods of analysis-Determination of pesticides in sediment using gas chromatography/mass spectrometry

    Science.gov (United States)

    Hladik, Michelle; McWayne, Megan M.

    2012-01-01

    A method for the determination of 119 pesticides in environmental sediment samples is described. The method was developed by the U.S. Geological Survey (USGS) in support of the National Water Quality Assessment (NAWQA) Program. The pesticides included in this method were chosen through prior prioritization. Herbicides, insecticides, and fungicides along with degradates are included in this method and span a variety of chemical classes including, but not limited to, chloroacetanilides, organochlorines, organophosphates, pyrethroids, triazines, and triazoles. Sediment samples are extracted by using an accelerated solvent extraction system (ASE®, and the compounds of interest are separated from co-extracted matrix interferences (including sulfur) by passing the extracts through high performance liquid chromatography (HPLC) with gel-permeation chromatography (GPC) along with the use of either stacked graphitized carbon and alumina solid-phase extraction (SPE) cartridges or packed Florisil®. Chromatographic separation, detection, and quantification of the pesticides from the sediment-sample extracts are done by using gas chromatography with mass spectrometry (GC/MS). Recoveries in test sediment samples fortified at 10 micrograms per kilogram (μg/kg) dry weight ranged from 75 to 102 percent; relative standard deviations ranged from 3 to 13 percent. Method detection limits (MDLs), calculated by using U.S. Environmental Protection Agency procedures (40 CFR 136, Appendix B), ranged from 0.6 to 3.4 μg/kg dry weight.

  14. Gas Chromatography-Mass Spectroscopic (GC-MS) Analysis of n ...

    African Journals Online (AJOL)

    tuber-regium (synonym Pleurotus tuber regium) using gas chromatography-mass spectroscopic (GC-. MS) techniques. Methods: The n-hexane extract of the sclerotia ... Soxhlet extraction and analysed using gas chromatography-mass spectroscopic (MS) techniques. ..... Phytochemical composition of Pleurotus tuber regium.

  15. Axial liquid mixing in a gas-liquid Multi-Stage Agitated Contactor (MAC)

    NARCIS (Netherlands)

    Breman, B.B; Beenackers, A.A C M; Bouma, M.J; VanderWerf, M.H.

    Data on interstage liquid mixing are reported for a gas-liquid Multi-stage Agitated Contactor (MAC). A dynamic method using heat as a tracer was applied for water, n-octane and monoethylene glycol as liquids both with and without the presence of a dispersed gas phase (air). In all cases, the axial

  16. Monitoring aldehyde production during frying by reversed-phase liquid chromatography.

    Science.gov (United States)

    Lane, R H; Smathers, J L

    1991-01-01

    Acrolein (2-propenal) and other low molecular weight aldehydes (LMWAs) formed by degradation of the frying medium (triglycerides) were monitored by liquid chromatography (LC) during preparation of fried items. LMWA contents of coatings from codfish and of doughnuts and their volatiles that codistill with steam are monitored by trapping the vapors and distillate from the food matrix in a 2,4-dinitrophenylhydrazine solution. The resulting hydrazones are partitioned from the aqueous phase, first into isooctane and then into acetonitrile for LC analysis. The hydrazones are separated and quantified on a C18 reversed-phase column with acetonitrile-water as the mobile phase. LMWAs are confirmed by gas chromatography/mass spectrometry. No difference was found in LMWA content in coatings from fish fillets fried at 182 or 204 degrees C. Cake doughnuts were higher in acrolein content than yeast-raised doughnuts prepared under similar conditions. Freshness of the frying medium, frying time, and batch size did not seem to influence LMWA production from doughnuts. Results indicated that most of the LMWAs formed codistilled with steam during frying rather than remaining with the food item.

  17. Recent advances and applications of gas chromatography vacuum ultraviolet spectroscopy.

    Science.gov (United States)

    Santos, Inês C; Schug, Kevin A

    2017-01-01

    The vacuum ultraviolet spectrophotometer was developed recently as an alternative to existing gas chromatography detectors. This detector measures the absorption of gas-phase chemical species in the range of 120-240 nm, where all chemical compounds present unique absorption spectra. Therefore, qualitative analysis can be performed and quantification follows standard Beer-Lambert law principles. Different fields of application, such as petrochemical, food, and environmental analysis have been explored. Commonly demonstrated is the capability for facile deconvolution of co-eluting analytes. The concept of additive absorption for co-eluting analytes has also been advanced for classification and speciation of complex mixtures using a data treatment procedure termed time interval deconvolution. Furthermore, pseudo-absolute quantitation can be performed for system diagnosis, as well as potentially calibrationless quantitation. In this manuscript an overview of these features, the vacuum ultraviolet spectrophotometer instrumentation, and performance capabilities are given. A discussion of the applications of the vacuum ultraviolet detector is provided by describing and discussing the papers published thus far since 2014. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Chromatography.

    Science.gov (United States)

    Brantley, L. Reed, Sr.; Demanche, Edna L.; Klemm, E. Barbara; Kyselka, Will; Phillips, Edwin A.; Pottenger, Francis M.; Yamamoto, Karen N.; Young, Donald B.

    This booklet presents some activities on chromatography. Directions for preparing leaf pigment extracts using alcohol are given, and paper chromatography and thin-layer chromatography are described as modifications of the basic principles of chromatography. (KHR)

  19. Fuel gas production by microwave plasma in liquid

    International Nuclear Information System (INIS)

    Nomura, Shinfuku; Toyota, Hiromichi; Tawara, Michinaga; Yamashita, Hiroshi; Matsumoto, Kenya

    2006-01-01

    We propose to apply plasma in liquid to replace gas-phase plasma because we expect much higher reaction rates for the chemical deposition of plasma in liquid than for chemical vapor deposition. A reactor for producing microwave plasma in a liquid could produce plasma in hydrocarbon liquids and waste oils. Generated gases consist of up to 81% hydrogen by volume. We confirmed that fuel gases such as methane and ethylene can be produced by microwave plasma in liquid

  20. Development of an on-line mixed-mode gel liquid chromatography×reversed phase liquid chromatography method for separation of water extract from Flos Carthami.

    Science.gov (United States)

    Wang, Yu-Qing; Tang, Xu; Li, Jia-Fu; Wu, Yun-Long; Sun, Yu-Ying; Fang, Mei-Juan; Wu, Zhen; Wang, Xiu-Min; Qiu, Ying-Kun

    2017-10-13

    A novel on-line comprehensive two-dimensional liquid chromatography (2D-LC) method by coupling mixed-mode gel liquid chromatography (MMG-LC) with reversed phase liquid chromatography (RPLC) was developed. A mixture of 17 reference compounds was used to study the separation mechanism. A crude water extract of Flos Carthami was applied to evaluate the performance of the novel 2D-LC system. In the first dimension, the extract was eluted with a gradient of water/methanol over a cross-linked dextran gel Sephadex LH-20 column. Meanwhile, the advantages of size exclusion, reversed phase partition and adsorption separation mechanism were exploited before further on-line reversed phase purification on the second dimension. This novel on-line mixed-mode Sephadex LH-20×RPLC method provided higher peak resolution, sample processing ability (2.5mg) and better orthogonality (72.9%) versus RPLC×RPLC and hydrophilic interaction liquid chromatography (HILIC)×RPLC. To the best of our knowledge, this is the first report of a mixed-mode Sephadex LH-20×RPLC separation method with successful applications in on-line mode, which might be beneficial for harvesting targets from complicated medicinal plants. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Carbon monoxide measurement by gas chromatography; Mesure du monoxyde de carbone par chromatographie en phase gazeuse

    Energy Technology Data Exchange (ETDEWEB)

    Gros, V.; Sarda-Esteve, R.; Bonsang, B.; Ramonet, M.

    1998-09-01

    Although carbon monoxide (CO) is present in trace quantities in the atmosphere (0.1 ppm -or parts per million in volume- on average), the study of this gas is important. Indeed, its impact on human can be dangerous at high level of concentration on the hand and it constitutes one of the main precursor of ozone in presence of concentration on the one hand and it constitutes one of the main precursor of ozone in presence of other pollutants on the other hand. Finally, CO affects the levels of several important greenhouse gases, through its reaction with hydroxyl radicals (OH). CO is measured in the atmosphere since the mid 60's by various methods. Among them, gas chromatography has the advantage to combine a low detection limit with a high precision. This report details the improvements made on the measurement analyser which allowed to perform automatic CO measurements in remote areas with low mixing ratios of carbon monoxide. This report describes some quality tests and the results of various applications. (authors)

  2. Thermal transistor utilizing gas-liquid transition

    KAUST Repository

    Komatsu, Teruhisa S.

    2011-01-25

    We propose a simple thermal transistor, a device to control heat current. In order to effectively change the current, we utilize the gas-liquid transition of the heat-conducting medium (fluid) because the gas region can act as a good thermal insulator. The three terminals of the transistor are located at both ends and the center of the system, and are put into contact with distinct heat baths. The key idea is a special arrangement of the three terminals. The temperature at one end (the gate temperature) is used as an input signal to control the heat current between the center (source, hot) and another end (drain, cold). Simulating the nanoscale systems of this transistor, control of heat current is demonstrated. The heat current is effectively cut off when the gate temperature is cold and it flows normally when it is hot. By using an extended version of this transistor, we also simulate a primitive application for an inverter. © 2011 American Physical Society.

  3. Microfabricated planar glass gas chromatography with photoionization detection.

    Science.gov (United States)

    Lewis, Alastair C; Hamilton, Jacqueline F; Rhodes, Christopher N; Halliday, Jaydene; Bartle, Keith D; Homewood, Philip; Grenfell, Robin J P; Goody, Brian; Harling, Alice M; Brewer, Paul; Vargha, Gergely; Milton, Martin J T

    2010-01-29

    We report the development of a microfabricated gas chromatography system suitable for the separation of volatile organic compounds (VOCs) and compatible with use as a portable measurement device. Hydrofluoric acid etching of 95x95mm Schott B270 wafers has been used to give symmetrical hemi-spherical channels within a glass substrate. Two matching glass plates were subsequently cold bonded with the channels aligned; the flatness of the glass surfaces resulted in strong bonding through van der Waals forces. The device comprised gas fluidic interconnections, injection zone and 7.5 and 1.4m long, 320microm internal diameter capillaries. Optical microscopy confirmed the capillaries to have fully circular channel profiles. Direct column heating and cooling could be achieved using a combination of resistive heaters and Peltier devices. The low thermal conductivity of glass allowed for multiple uniform temperature zones to be achieved within a single glass chip. Temperature control over the range 10-200 degrees C was achieved with peak power demand of approximately 25W. The 7.5m capillary column was static coated with a 2microm film of non-polar dimethylpolysiloxane stationary phase. A standard FID and a modified lightweight 100mW photoionization detector (PID) were coupled to the column and performance tested with gas mixtures of monoaromatic and monoterpene species at the parts per million concentration level. The low power GC-PID device showed good performance for a small set of VOCs and sub ng detection sensitivity to monoaromatics. Copyright (c) 2009 Elsevier B.V. All rights reserved.

  4. Evaluation of a silicon oxynitride hydrophilic interaction liquid chromatography column in saccharide and glycoside separations.

    Science.gov (United States)

    Wan, Huihui; Sheng, Qianying; Zhong, Hongmin; Guo, Xiujie; Fu, Qing; Liu, Yanfang; Xue, Xingya; Liang, Xinmiao

    2015-05-01

    The retention characteristics of a silicon oxynitride stationary phase for carbohydrate separation were studied in hydrophilic interaction chromatography mode. Four saccharides including mono-, di-, and trisaccharides were employed to investigate the effects of water content and buffer concentration in the mobile phase on hydrophilic interaction liquid chromatography retention. For the tested saccharides, the silicon oxynitride column demonstrated excellent performance in terms of separation efficiency, hydrophilicity, and interesting separation selectivity for carbohydrates compared to the bare silica stationary phase. Finally, the silicon oxynitride hydrophilic interaction liquid chromatography column was employed in the separation of complex samples of fructooligosaccharides, saponins, and steviol glycoside from natural products. The resulting chromatograms demonstrated good separation efficiency and longer retention compared with silica, which further confirmed the advantages and potential application of silicon oxynitride stationary phase for hydrophilic interaction liquid chromatography separation. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. A study of the chemical composition of peat humic acids by adsorption liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Platonov, V.V.; Proskuryakov, V.A.; Surasinkha, S.; Platonova, M.V.; Taran, N.A. [Lev Tolstoi State Pedagogical University, Tula (Russian Federation)

    1998-12-01

    The chemical composition of peat humic acids was studied in detail by IR and UV spectroscopy, elemental, emission spectral X-ray fluorescence, and structural-group analyses, cryoscopy, and capillary gas chromatography.

  6. An electrospray ionization-ion mobility spectrometer as detector for high- performance liquid chromatography.

    Science.gov (United States)

    Zühlke, Martin; Riebe, Daniel; Beitz, Toralf; Löhmannsröben, Hans-Gerd; Zenichowski, Karl; Diener, Marc; Linscheid, Michael W

    2015-01-01

    The application of electrospray ionization (ESI) ion mobility (IM) spectrometry on the detection end of a high-performance liquid chromatograph has been a subject of study for some time. So far, this method has been limited to low flow rates or has required splitting of the liquid flow. This work presents a novel concept of an ESI source facilitating the stable operation of the spectrometer at flow rates between 10 μL mn(-1) and 1500 μL min(-1) without flow splitting, advancing the T-cylinder design developed by Kurnin and co-workers. Flow rates eight times faster than previously reported were achieved because of a more efficient dispersion of the liquid at increased electrospray voltages combined with nebulization by a sheath gas. Imaging revealed the spray operation to be in a rotationally symmetric multijet mode. The novel ESI-IM spectrometer tolerates high water contents (≤90%) and electrolyte concentrations up to 10mM, meeting another condition required of high-performance liquid chromatography (HPLC) detectors. Limits of detection of 50 nM for promazine in the positive mode and 1 μM for 1,3-dinitrobenzene in the negative mode were established. Three mixtures of reduced complexity (five surfactants, four neuroleptics, and two isomers) were separated in the millisecond regime in stand-alone operation of the spectrometer. Separations of two more complex mixtures (five neuroleptics and 13 pesticides) demonstrate the application of the spectrometer as an HPLC detector. The examples illustrate the advantages of the spectrometer over the established diode array detector, in terms of additional IM separation of substances not fully separated in the retention time domain as well as identification of substances based on their characteristic Ims.

  7. Mass transfer and chemical reaction in gas-liquid-liquid systems

    NARCIS (Netherlands)

    Brilman, Derk Willem Frederik

    1998-01-01

    Gas-liquid-liquid reaction systems may be encountered in several important fields of application as e.g. hydroformylation, alkylation, carboxylation, polymerisation, hydrometallurgy, biochemical processes and fine chemicals manufacturing. However, the reaction engineering aspects of these systems

  8. Mass transfer in gas-liquid slurry reactors

    NARCIS (Netherlands)

    Beenackers, A.A.C.M.; van Swaaij, Willibrordus Petrus Maria

    1993-01-01

    A critical review is presented on the mass transfer characteristics of gas¿liquid slurry reactors. The recent findings on the influence of the presence of solid particles on the following mass transfer parameters in slurry reactors are discussed: volumetric gas¿liquid mass transfer coefficients

  9. Fluid dynamics of gas-liquid bubble columns

    NARCIS (Netherlands)

    Delnoij, E.

    1999-01-01

    Gas-liquid bubble columns are used extensively in the process industries. The gas-liquid twophase flow prevailing in this type of process equipment is extremely complex, inherently unsteady and dominated by phenomena with widely varying time- and length-scales. it is for this reason that many

  10. Vapor Pressure Determination of VM Using the Denunder-Liquid Chromatography-Mass Spectrometry Technique

    Science.gov (United States)

    2015-01-01

    allow for the real-time detection that is required for breakthrough studies. Alternatively, instrumentation such as gas chromatography –mass...Making and Manipulating Capillary Columns for Gas Chromatography ; Huethig: Heidelberg, 1986. 2. Geankoplis, C.J. Transport Processes and Unit... Hydrogen Fluoride Analyzer for Gases and Aerosols. Anal. Chim. Acta 2002, 460, 219–225. 6. Hoke, S.H.; Herud, C. Halon Alternatives Technical Working

  11. Analysis of dichloroacetic acid in rat blood and tissues by hydrophilic interaction liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Delinsky, Amy D; Delinsky, David C; Muralidhara, S; Fisher, Jeffrey W; Bruckner, James V; Bartlett, Michael G

    2005-01-01

    Dichloroacetic acid (DCA) is a compound found in chlorinated drinking water. In addition, the compound is a metabolite of several halogenated solvents, including trichloroethylene (TCE) and perchloroethylene (PCE). Exposure to DCA is of concern because high doses of the compound have been shown to cause cancer in laboratory animals. Dosages of TCE administered to animals in cancer studies are designed to elicit maximal DCA formation in vivo, whereas levels of DCA to which individuals are exposed in drinking water are very low. Analysis of DCA in biological samples has been quite challenging. Derivatizing reagents commonly used to convert DCA into a more volatile form for analysis by gas chromatography (GC) have been found to convert trichloroacetic acid (TCA), a major metabolite of TCE and PCE, into DCA. High-performance liquid chromatography (HPLC) analysis does not require derivatization of DCA and can thus avoid this problem. However, the most popular stationary phases in HPLC columns do not retain small, polar compounds such as DCA well. The liquid chromatography/tandem mass spectrometry (LC/MS/MS) method described in this paper uses hydrophilic interaction liquid chromatography (HILIC), a type of chromatography that is able to retain these small, polar compounds. Method validation was performed using the United States Food and Drug Administration (USFDA) and International Conference on Harmonziation (ICH) Guidance for Industry: Bioanalytical Method Validation as a guide. Levels of DCA found in rats dosed with 2 g/kg TCE were 17.2 ng/mL (liver), 262.4 ng/mL (kidney), 175.1 ng/mL (lung), and 39.5 ng/mL (blood). Copyright 2005 John Wiley & Sons, Ltd.

  12. Hollow fiber gas-liquid membrane contactors for acid gas capture: a review.

    Science.gov (United States)

    Mansourizadeh, A; Ismail, A F

    2009-11-15

    Membrane contactors using microporous membranes for acid gas removal have been extensively reviewed and discussed. The microporous membrane acts as a fixed interface between the gas and the liquid phase without dispersing one phase into another that offers a flexible modular and energy efficient device. The gas absorption process can offer a high selectivity and a high driving force for transport even at low concentrations. Using hollow fiber gas-liquid membrane contactors is a promising alternative to conventional gas absorption systems for acid gas capture from gas streams. Important aspects of membrane contactor as an efficient energy devise for acid gas removal including liquid absorbents, membrane characteristics, combination of membrane and absorbent, mass transfer, membrane modules, model development, advantages and disadvantages were critically discussed. In addition, current status and future potential in research and development of gas-liquid membrane contactors for acid gas removal were also briefly discussed.

  13. Characterization of synthetic dyes by comprehensive two-dimensional liquid chromatography combining ion-exchange chromatography and fast ion-pair reversed-phase chromatography.

    Science.gov (United States)

    Pirok, Bob W J; Knip, Jitske; van Bommel, Maarten R; Schoenmakers, Peter J

    2016-03-04

    In the late 19th century, newly invented synthetic dyes rapidly replaced the natural dyes on the market. The characterization of mixtures of these so-called early synthetic dyes is complicated through the occurrence of many impurities and degradation products. Conventional one-dimensional liquid chromatography does not suffice to obtain fingerprints with sufficient resolution and baseline integrity. Comprehensive two-dimensional liquid chromatography (LC×LC) is employed in this study, with ion-exchange chromatography in the first dimension and fast ion-pair liquid chromatography in the second. Retention in the first dimension is largely determined by the number of charges, while the selection of a small ion-pair reagent (tetramethylammonium hydroxide) in the second dimension causes retention to be largely determined by the molecular structure of the dye. As a result, there is a high degree of orthogonality of the two dimensions, similar to the values typically encountered in GC×GC. The proposed LC×LC method shows a theroretical peak capacity of about 2000 in an analysis time of about three hours. Clear, informative fingerprints are obtained that open a way to a more efficient characterization of dyes used in objects of cultural heritage. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Preparation and evaluation of surface-bonded tricationic ionic liquid silica as stationary phases for high-performance liquid chromatography.

    Science.gov (United States)

    Qiao, Lizhen; Shi, Xianzhe; Lu, Xin; Xu, Guowang

    2015-05-29

    Two tricationic ionic liquids were prepared and then bonded onto the surface of supporting silica materials through "thiol-ene" click chemistry as new stationary phases for high-performance liquid chromatography. The obtained columns of tricationic ionic liquids were evaluated respectively in the reversed-phase liquid chromatography (RPLC) mode and hydrophilic interaction liquid chromatography (HILIC) mode, and possess ideal column efficiency of 80,000 plates/m in the RPLC mode with naphthalene as the test solute. The tricationic ionic liquid stationary phases exhibit good hydrophobic and shape selectivity to hydrophobic compounds, and RPLC retention behavior with multiple interactions. In the HILIC mode, the retention and selectivity were evaluated through the efficient separation of nucleosides and bases as well as flavonoids, and the typical HILIC retention behavior was demonstrated by investigating retention changes of hydrophilic solutes with water volume fraction in mobile phase. The results show that the tricationic ionic liquid columns possess great prospect for applications in analysis of hydrophobic and hydrophilic samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Gas-liquid flow filed in agitated vessels

    International Nuclear Information System (INIS)

    Hormazi, F.; Alaie, M.; Dabir, B.; Ashjaie, M.

    2001-01-01

    Agitated vessels in form of sti reed tank reactors and mixed ferment ors are being used in large numbers of industry. It is more important to develop good, and theoretically sound models for scaling up and design of agitated vessels. In this article, two phase flow (gas-liquid) in a agitated vessel has been investigated numerically. A two-dimensional computational fluid dynamics model, is used to predict the gas-liquid flow. The effects of gas phase, varying gas flow rates and variation of bubbles shape on flow filed of liquid phase are investigated. The numerical results are verified against the experimental data

  16. Identification and classification of components in flash pyrolysis oil and hydrodeoxygenated oils by two-dimensional gas chromatography and time-of-flight mass spectrometry

    NARCIS (Netherlands)

    Marsman, J. H.; Wildschut, J.; Evers, P.; Heeres, H. J.; Koning de, S.

    2008-01-01

    Hydrodeoxygenated pyrolysis oils (HDO) are considered promising renewable liquid energy carriers. To gain insights in the various reaction pathways taking place during the hydrodeoxygenation reaction of pyrolysis oil, two-dimensional gas chromatography with time-of-flight mass spectrometric analyses

  17. Gas Chromatography-Mass Spectroscopy Study of tert-Butylarsine Stability and Purification

    Energy Technology Data Exchange (ETDEWEB)

    Bartram, M.E.; Breiland, W.G.; Bruskas, L.A.; Killeen, K.P.

    1999-07-20

    TBA (tert-butylarsine, H{sub 2}AsC(CH{sub 3}){sub 3}) has been demonstrated to be an effective arsenic precursor for the deposition of compound semiconductors such as GaAs by MOCVD (metal organic chemical vapor deposition). TBA is used as a liquid (bubbler) source in MOCVD and is a less toxic alternative to the more commonly used gaseous arsine (AsH{sub 3}). Materials and device performance using TBA have in many cases equaled or surpassed those using arsine. This includes the first observation of fractional quantum Hall behavior in a two dimensional electron gas structure grown by MOCVD. Despite the beneficial characteristics, the use of TBA in our laboratories has revealed some inconsistent behavior. Small pressure rises have been observed in the TBA bubbler sources when left unused over a period of many days. Measurements of the TBA partial pressure using UV absorption revealed that new absorption peaks could be observed after storage. The features of the absorption profile were insufficient to ascribe to a specific chemical species. Attempts to remove the gaseous impurities with liquid nitrogen freeze-pump-thaw techniques had limited success. Unfortunately, there is no published information on the room temperature decomposition of TBA. In this paper, we present a series of GCMS (gas chromatography-mass spectroscopy) analyses designed to determine the stability of TBA and identify its decomposition products in storage containers. The GCMS is also used to evaluate several methods for in-situ purification of TBA.

  18. Analysis of chlorpheniramine in human urine samples using dispersive liquid-liquid microextraction combined with high-performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Mehdi Maham

    2014-09-01

    Full Text Available A simple and environmentally friendly microextraction technique was used for determination of chlorpheniramine (CPM, an antihistamine drug, in human urine samples using dispersive liquid-liquid microextraction (DLLME followed by high performance liquid chromatography with diode array detection (HPLC-DAD. In this extraction technique, an appropriate mixture of acetonitrile (disperser solvent and carbon tetrachloride (extraction solvent was rapidly injected into the urine sample containing the target analyte. Tiny droplets of extractant were formed and dispersed into the sample solution and then sedimented at the bottom of the conical test tube by centrifugation. Under optimal conditions, the calibration curve was linear in the range of 0.055-5.5 µg mL-1, with a detection limit of 16.5 ng mL-1. This proposed method was successfully applied to the analysis of real urine samples. Low consumption of toxic organic solvents, simplicity of operation, low cost and acceptable figures of merit are the main advantages of the proposed technique.

  19. Recent applications of gas chromatography with high-resolution mass spectrometry.

    Science.gov (United States)

    Špánik, Ivan; Machyňáková, Andrea

    2018-01-01

    Gas chromatography coupled to high-resolution mass spectrometry is a powerful analytical method that combines excellent separation power of gas chromatography with improved identification based on an accurate mass measurement. These features designate gas chromatography with high-resolution mass spectrometry as the first choice for identification and structure elucidation of unknown volatile and semi-volatile organic compounds. Gas chromatography with high-resolution mass spectrometry quantitative analyses was previously focused on the determination of dioxins and related compounds using magnetic sector type analyzers, a standing requirement of many international standards. The introduction of a quadrupole high-resolution time-of-flight mass analyzer broadened interest in this method and novel applications were developed, especially for multi-target screening purposes. This review is focused on the development and the most interesting applications of gas chromatography coupled to high-resolution mass spectrometry towards analysis of environmental matrices, biological fluids, and food safety since 2010. The main attention is paid to various approaches and applications of gas chromatography coupled to high-resolution mass spectrometry for non-target screening to identify contaminants and to characterize the chemical composition of environmental, food, and biological samples. The most interesting quantitative applications, where a significant contribution of gas chromatography with high-resolution mass spectrometry over the currently used methods is expected, will be discussed as well. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Identification of inorganic anions by gas chromatography/mass spectrometry.

    Science.gov (United States)

    Sakayanagi, Masataka; Yamada, Yaeko; Sakabe, Chikako; Watanabe, Kunio; Harigaya, Yoshihiro

    2006-03-10

    Inorganic anions were identified by using gas chromatography/mass spectrometry (GC/MS). Derivatization of the anions was achieved with pentafluorobenzyl p-toluenesulphonate (PFB-Tos) as the reaction reagent and a crown ether as a phase transfer catalyst. When PFB-Br was used as the reaction reagent, the retention time of it was close to those of the derivatized inorganic anions and interfered with the analysis. In contrast, the retention time of PFB-Tos differed greatly from the PFB derivatives of the inorganic anions and the compounds of interest could be detected without interference. Although the PFB derivatives of SO4, S2O3, CO3, ClO4, and ClO3 could not be detected, the derivatives of F, Cl, Br, I, CN, OCN, SCN, N3, NO3, and NO2 were detected using PFB-Tos as the derivatizing reagent. The inorganic anions were detectable within 30 ng approximately, which is of sufficient sensitivity for use in forensic chemistry. Accurate mass number was measured for each PFB derivative by high-resolution mass spectrometry (HRMS) within a measurement error of 2 millimass units (mmu), which allowed determination of the compositional formula from the mass number. In addition, actual analysis was performed successively by our method using trial samples of matrix.

  1. Characterization of aldolase from Methanococcus jannaschii by gas chromatography.

    Science.gov (United States)

    Nam Shin, Jeong E; Kim, Mi-Jung; Choi, Ji-ah; Chun, Keun Ho

    2007-09-30

    The products of reactions catalyzed by Methanococcus. jannaschii (Mj) aldolase using various substrates were identified by gas chromatography (GC). Although Mj aldolase is considered a fuculose-1-phosphate aldolase based on homology searching after gene sequencing, it has not been proven to be a fuculose-1-phosphate aldolase based on its reaction products. Mj aldolase was found to catalyze reactions between glycoaldehyde or D, L-glyceraldehyde and DHAP (dihydroxyacetone phosphate). Before performing GC the ketoses produced were converted into peracetylated alditol derivatives by sequential reactions, i.e., dephosphorylation, NaBH(4) reduction, and acetylation. By comparing the GC data of final products with those of standard alditol samples, it was found that the enzymatic reactions with glycoaldehyde, D-glyceraldehyde, and D, L-glyceraldehyde produced D-ribulose-1-phosphate, D-psicose-1-phosphate, and a mixture of D-psicose and L-tagatose-1-phosphate, respectively. These results provide direct evidence that Mj aldolase is a fuculose-1-phosphate aldolase.

  2. Electronic Nose using Gas Chromatography Column and Quartz Crystal Microbalance

    Directory of Open Access Journals (Sweden)

    Hari Agus Sujono

    2011-08-01

    Full Text Available The conventional electronic nose usually consists of an array of dissimilar chemical sensors such as quartz crystal microbalance (QCM combined with pattern recognition algorithm such as Neural network. Because of parallel processing, the system needs a huge number of sensors and circuits which may emerge complexity and inter-channel crosstalk problems. In this research, a new type of odor identification which combines between gas chromatography (GC and electronic nose methods has been developed. The system consists of a GC column and a 10-MHz quartz crystal microbalance sensor producing a unique pattern for an odor in time domain. This method offers advantages of substantially reduced size, interferences and power consumption in comparison to existing odor identification system. Several odors of organic compounds were introduced to evaluate the selectivity of the system. Principle component analysis method was used to visualize the classification of each odor in two-dimensional space. This system could resolve common organic solvents, including molecules of different classes (aromatic from alcohols as well as those within a particular class (methanol from ethanol and also fuels (premium from pertamax. The neural network can be taught to recognize the odors tested in the experiment with identification rate of 85 %. It is therefore the system may take the place of human nose, especially for poisonous odor evaluations.

  3. High-performance liquid chromatography analysis methods developed for quantifying enzymatic esterification of flavonoids in ionic liquids

    DEFF Research Database (Denmark)

    Lue, Bena-Marie; Guo, Zheng; Xu, X.B.

    2008-01-01

    Methods using reversed-phase high-performance liquid chromatography (RP-HPLC) with ELSD were investigated to quantify enzymatic reactions of flavonoids with fatty acids in the presence of diverse room temperature ionic liquids (RTILs). A buffered salt (preferably triethylamine-acetate) was found ...... developed was successfully applied for primary screening of RTILs (> 20), with in depth evaluation of substrates in 10 RTILs, for their evaluation as reaction media....

  4. Comprehensive two-dimensional liquid chromatography for polyphenol analysis in foodstuffs.

    Science.gov (United States)

    Cacciola, Francesco; Farnetti, Sara; Dugo, Paola; Marriott, Philip John; Mondello, Luigi

    2017-01-01

    Polyphenols are a class of plant secondary metabolites that are recently drawing a special interest because of their broad spectrum of pharmacological effects. As they are characterized by an enormous structural variability, the identification of these molecules in food samples is a difficult task, and sometimes having only a limited number of commercially available reference materials is not of great help. One-dimensional liquid chromatography is the most widely applied analytical approach for their analysis. In particular, the hyphenation of liquid chromatography to mass spectrometry has come to play an influential role by allowing relatively fast tentative identification and accurate quantification of polyphenolic compounds at trace levels in vegetable media. However, when dealing with very complex real-world food samples, a single separation system often does not provide sufficient resolving power for attaining rewarding results. Comprehensive two-dimensional liquid chromatography is a technique of great analytical impact, since it offers much higher peak capacities than separations in a single dimension. In the present review, we describe applications in the field of comprehensive two-dimensional liquid chromatography for polyphenol analysis in real-world food samples. Comprehensive two-dimensional liquid chromatography applications to nonfood matrices fall outside the scope of the current report and will not be discussed. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. U.S. crude oil, natural gas, and natural gas liquids reserves 1995 annual report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-11-01

    The EIA annual reserves report series is the only source of comprehensive domestic proved reserves estimates. This publication is used by the Congress, Federal and State agencies, industry, and other interested parties to obtain accurate estimates of the Nation`s proved reserves of crude oil, natural gas, and natural gas liquids. These data are essential to the development, implementation, and evaluation of energy policy and legislation. This report presents estimates of proved reserves of crude oil, natural gas, and natural gas liquids as of December 31, 1995, as well as production volumes for the US and selected States and State subdivisions for the year 1995. Estimates are presented for the following four categories of natural gas: total gas (wet after lease separation), nonassociated gas and associated-dissolved gas (which are the two major types of wet natural gas), and total dry gas (wet gas adjusted for the removal of liquids at natural gas processing plants). In addition, reserve estimates for two types of natural gas liquids, lease condensate and natural gas plant liquids, are presented. Also included is information on indicated additional crude oil reserves and crude oil, natural gas, and lease condensate reserves in nonproducing reservoirs. A discussion of notable oil and gas exploration and development activities during 1995 is provided. 21 figs., 16 tabs.

  6. US crude oil, natural gas, and natural gas liquids reserves 1996 annual report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-12-01

    The EIA annual reserves report series is the only source of comprehensive domestic proved reserves estimates. This publication is used by the Congress, Federal and State agencies, industry, and other interested parties to obtain accurate estimates of the Nation`s proved reserves of crude oil, natural gas, and natural gas liquids. These data are essential to the development, implementation, and evaluation of energy policy and legislation. This report presents estimates of proved reserves of crude oil, natural gas, and natural gas liquids as of December 31, 1996, as well as production volumes for the US and selected States and State subdivisions for the year 1996. Estimates are presented for the following four categories of natural gas: total gas (wet after lease separation), nonassociated gas and associated-dissolved gas (which are the two major types of wet natural gas), and total dry gas (wet gas adjusted for the removal of liquids at natural gas processing plants). In addition, reserve estimates for two types of natural gas liquids, lease condensate and natural gas plant liquids, are presented. Also included is information on indicated additional crude oil reserves and crude oil, natural gas, and lease condensate reserves in nonproducing reservoirs. A discussion of notable oil and gas exploration and development activities during 1996 is provided. 21 figs., 16 tabs.

  7. Isolation and purification of six iridoid glycosides from gardenia jasminoides fruit by medium-pressure liquid chromatography combined with macroporous resin chromatography.

    Science.gov (United States)

    Wang, Yun; Liu, Hui; Shen, Lifeng; Yao, Lan; Ma, Yinlian; Yu, Dingrong; Chen, Jianhong; Li, Puling; Chen, Ying; Zhang, Cun

    2015-12-01

    Gardeniae fructus is one of the most frequently used herbs in traditional Chinese medicine. In the present study, a process for the enrichment of six iridoid glycosides from Gardeniae fructus was developed using medium-pressure liquid chromatography combined with macroporous resin and reversed-phase chromatography. The purities of different fractions from Gardeniae fructus were assessed using quantitative high-performance liquid chromatography. After fractionation using HPD-100 column chromatography, a 30% ethanol fraction was selected based on high-performance liquid chromatography and liquid chromatography with mass spectrometry qualitative analysis to separate and purify. Based on the orientation analysis results, six compounds-deacetyl asperulosidic acid methyl ester, gardenoside, ixoroside, scandoside methyl ester, genipin-1-O-β-d-gentiobioside, and geniposide-were successfully isolated and purified in three to four combined steps from Gardeniae fructus. The purities of these compounds were found by high-performance liquid chromatography analysis to be 97.9, 98.1, 95.5, 96.3, 97.1, and 98.7%, respectively. Moreover, their structures were elucidated by NMR spectroscopy and liquid chromatography with tandem mass spectrometry. The separation process was highly efficient, rapid, and accurate, making it a potential approach for the large-scale production of iridoids in the laboratory and providing several marker compounds for quality control. This procedure may be meaningful for the purification of other natural products used in traditional Chinese medicine. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Determination of tributyltin (TBT) in marine sediment using pressurised liquid extraction-gas chromatography-isotope dilution mass spectrometry (PLE-GC-IDMS) with a hexane-tropolone mixture.

    Science.gov (United States)

    Konieczka, Piotr; Sejerøe-Olsen, Berit; Linsinger, Thomas P J; Schimmel, Heinz

    2007-06-01

    Extraction conditions for the determination of tributyltin (TBT) in sediment samples have been developed further. The analytical procedure is based on spiking with isotopically labelled analyte, pressurised liquid extraction (PLE) with a hexane/tropolone mixture, Grignard derivatization and quantification by GC-MS. It was applied to two unknown sediment samples as part of an intercomparison exercise of the Comité Consultatif pour la Quantité de Matière (CCQM). The detection limit was approximately 1.5 ng/g TBT as Sn, while the repeatability and intermediate precision (as the coefficient of variation) were 1.9% and 3.2%, respectively. The expanded uncertainty was 6.2% (coverage factor k = 2), and the accuracy was confirmed by measurement of a certified reference material.

  9. Furanic compounds and furfural in different coffee products by headspace liquid-phase micro-extraction followed by gas chromatography-mass spectrometry: survey and effect of brewing procedures.

    Science.gov (United States)

    Chaichi, Maryam; Ghasemzadeh-Mohammadi, Vahid; Hashemi, Maryam; Mohammadi, Abdorreza

    2015-01-01

    In this study, the levels of furan, 2-methylfuran, 2,5-dimethylfuran, vinyl furan, 2-methoxymethyl-furan and furfural in different coffee products were evaluated. Simultaneous determination of these six furanic compounds was performed by a head space liquid-phase micro-extraction (HS-LPME) method. A total of 67 coffee powder samples were analysed. The effects of boiling and espresso-making procedures on the levels of furanic compounds were investigated. The results showed that different types of coffee samples contained different concentrations of furanic compounds, due to the various processing conditions such as temperature, degree of roasting and fineness of grind. Among the different coffee samples, the highest level of furan (6320 µg kg⁻¹) was detected in ground coffee, while coffee-mix samples showed the lowest furan concentration (10 µg kg⁻¹). Levels in brewed coffees indicated that, except for furfural, brewing by an espresso machine caused significant loss of furanic compounds.

  10. Transport evaluation of a gas-liquid scrubber

    International Nuclear Information System (INIS)

    Brodner, A.J.; Bistline, J.E.; Weber, S.E.

    1982-10-01

    The hydraulics and the mass-transfer behavior of a five-tray, single-bubble-cap, single-downcomer, gas-liquid contactor were studied for use as a gas scrubber. Flooding was not observed at the maximum available liquid and gas flow rates of 0.32 and 464 L/min, respectively. The maximum liquid entrainment was 33% at a gross liquid flow rate of 0.05 L/min. The Murphree-tray efficiencies for absorption of CO 2 (5000 ppM in air) into demineralized water ranged from 0.14 to 0.74 for volumetric liquid-to-gas ratios of 4 x 10 -4 and 2 x 10 -4 , respectively, for k/sub L/a values ranging from 0.088 to 0.36 min -1 . 12 figures, 10 tables

  11. Separation of Oligosaccharides from Lotus Seeds via Medium-pressure Liquid Chromatography Coupled with ELSD and DAD

    Science.gov (United States)

    Lu, Xu; Zheng, Zhichang; Miao, Song; Li, Huang; Guo, Zebin; Zhang, Yi; Zheng, Yafeng; Zheng, Baodong; Xiao, Jianbo

    2017-03-01

    Lotus seeds were identified by the Ministry of Public Health of China as both food and medicine. One general function of lotus seeds is to improve intestinal health. However, to date, studies evaluating the relationship between bioactive compounds in lotus seeds and the physiological activity of the intestine are limited. In the present study, by using medium pressure liquid chromatography coupled with evaporative light-scattering detector and diode-array detector, five oligosaccharides were isolated and their structures were further characterized by electrospray ionization-mass spectrometry and gas chromatography-mass spectrometry. In vitro testing determined that LOS3-1 and LOS4 elicited relatively good proliferative effects on Lactobacillus delbrueckii subsp. bulgaricus. These results indicated a structure-function relationship between the physiological activity of oligosaccharides in lotus seeds and the number of probiotics applied, thus providing room for improvement of this particular feature. Intestinal probiotics may potentially become a new effective drug target for the regulation of immunity.

  12. New Highly-Sensitive Ultra-Performance Liquid Chromatography ...

    African Journals Online (AJOL)

    chromatography mass spectrometry method for the quantification of the angiotensin II receptor antagonist, telmisartan (TEL), in human ... spectrometry with positive ion mode. The ion transitions recorded in multiple reaction monitoring mode ..... application of UPLC in pharmaceutical analysis. Talanta 2006; 68(3): 908-918.

  13. Screening and quantitative determination of twelve acidic and neutral pharmaceuticals in whole blood by liquid-liquid extraction and liquid chromatography-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Simonsen, Kirsten Wiese; Steentoft, Anni; Buck, Maike

    2010-01-01

    . The method was fully validated for salicylic acid, paracetamol, phenobarbital, carisoprodol, meprobamate, topiramate, etodolac, chlorzoxazone, furosemide, ibuprofen, warfarin, and salicylamide. The method also tentatively includes thiopental, theophylline, piroxicam, naproxen, diclophenac, and modafinil......We describe a multi-method for simultaneous identification and quantification of 12 acidic and neutral compounds in whole blood. The method involves a simple liquid-liquid extraction, and the identification and quantification are performed using liquid chromatography-tandem mass spectrometry...

  14. An optimized method for the measurement of acetaldehyde by high-performance liquid chromatography.

    Science.gov (United States)

    Guan, Xiangying; Rubin, Emanuel; Anni, Helen

    2012-03-01

    Acetaldehyde is produced during ethanol metabolism predominantly in the liver by alcohol dehydrogenase and rapidly eliminated by oxidation to acetate via aldehyde dehydrogenase. Assessment of circulating acetaldehyde levels in biological matrices is performed by headspace gas chromatography and reverse phase high-performance liquid chromatography (RP-HPLC). We have developed an optimized method for the measurement of acetaldehyde by RP-HPLC in hepatoma cell culture medium, blood, and plasma. After sample deproteinization, acetaldehyde was derivatized with 2,4-dinitrophenylhydrazine (DNPH). The reaction was optimized for pH, amount of derivatization reagent, time, and temperature. Extraction methods of the acetaldehyde-hydrazone (AcH-DNP) stable derivative and product stability studies were carried out. Acetaldehyde was identified by its retention time in comparison with AcH-DNP standard, using a new chromatography gradient program, and quantitated based on external reference standards and standard addition calibration curves in the presence and absence of ethanol. Derivatization of acetaldehyde was performed at pH 4.0 with an 80-fold molar excess of DNPH. The reaction was completed in 40 minutes at ambient temperature, and the product was stable for 2 days. A clear separation of AcH-DNP from DNPH was obtained with a new 11-minute chromatography program. Acetaldehyde detection was linear up to 80 μM. The recovery of acetaldehyde was >88% in culture media and >78% in plasma. We quantitatively determined the ethanol-derived acetaldehyde in hepatoma cells, rat blood and plasma with a detection limit around 3 μM. The accuracy of the method was volume (70 μl) plasma sampling. An optimized method for the quantitative determination of acetaldehyde in biological systems was developed using derivatization with DNPH, followed by a short RP-HPLC separation of AcH-DNP. The method has an extended linear range, is reproducible and applicable to small-volume sampling of culture

  15. Application of liquid column chromatography to preconcentration, separation and determination of platinum metals

    International Nuclear Information System (INIS)

    Alimarin, I.P.; Basova, E.M.; Bol'shova, T.A.; Ivanov, V.M.

    1986-01-01

    Separation and determination of platimum metals using the methods of adsorption, ion-pair, ion-exchange, distributing and sieve chromatography are discussed in the review of literature in 1971-1984. Separation and determination of metals as chelates using the method of adsorption and ion-pair chromatograpy are noted to be most perspective directions of developing highly effective liquid chromatography of inorganic systems

  16. Immunoaffinity chromatography of abscisic acid combined with electrospray liquid chromatography–mass spectrometry

    Czech Academy of Sciences Publication Activity Database

    Hradecká, Veronika; Novák, Ondřej; Havlíček, Libor; Strnad, Miroslav

    2007-01-01

    Roč. 847, č. 2 (2007), s. 162-173 ISSN 1570-0232 R&D Projects: GA MŠk(CZ) LC06034; GA AV ČR IBS5038351 Institutional research plan: CEZ:AV0Z50380511 Source of funding: V - iné verejné zdroje ; V - iné verejné zdroje Keywords : abscisic acid * immunoaffinity chromatography * liquid chromatography-mass spectrometry Subject RIV: ED - Physiology Impact factor: 2.935, year: 2007

  17. Hollow fiber membrane contactor as a gas-liquid model contactor

    OpenAIRE

    Dindore, V. Y.; Brilman, D. W. F.; Versteeg, G. F.

    2005-01-01

    Microporous hollow fiber gas-liquid membrane contactors have a fixed and well-defined gas-liquid interfacial area. The liquid flow through the hollow fiber is laminar, thus the liquid side hydrodynamics are well known. This allows the accurate calculation of the fiber side physical mass transfer coefficient from first principles. Moreover, in the case of gas-liquid membrane contactor, the gas-liquid exposure time can be varied easily and independently without disturbing the gas-liquid interfa...

  18. Characterization of natural organic colorants in historical and art objects by high-performance liquid chromatography.

    Science.gov (United States)

    Pauk, Volodymyr; Barták, Petr; Lemr, Karel

    2014-12-01

    High-performance liquid chromatography plays an important role in analysis of historical organic colorants. A number of papers have been published in this field over the last 30 years. Classification of the most commonly used natural dyes and an overview of high-performance liquid chromatography methods with main focus on recent works (2008 to the beginning of 2014) are provided. The review deals with an entire analytical protocol covering sample preparation, chromatographic separation, and suitable detection (UV/visible and fluorescent spectroscopy and mass spectrometric techniques). High-performance liquid chromatography has been successfully used in the complete characterization of some organic dyestuffs present in historical and art objects. The possibilities and difficulties for identification of natural sources of historical colorants are also discussed. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. The nature of ionic liquids in the gas phase.

    Science.gov (United States)

    Leal, João P; Esperança, José M S S; da Piedade, Manuel E Minas; Lopes, José N Canongia; Rebelo, Luís P N; Seddon, Kenneth R

    2007-07-19

    Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) experiments showed that when aprotic ionic liquids vaporize under pressure and temperature conditions similar to those of a reduced-pressure distillation, the gas phase is composed of discrete anion-cation pairs. The evolution of the mass spectrometric signals recorded during fractional distillations of binary ionic liquid mixtures allowed us to monitor the changes of the gas-phase composition and the relative volatility of the components. In addition, we have studied a protic ionic liquid, and demonstrated that it exists as separated neutral molecules in the gas phase.

  20. Determination of anabolic steroids with gas chromatography-ion trap mass spectrometry using hydrogen as carrier gas.

    Science.gov (United States)

    Impens, S; De Wasch, K; De Brabander, H

    2001-01-01

    Helium is considered to be the ideal carrier gas for gas chromatography/mass spectrometry (GC/MS) in general, and for use with an ion trap in particular. Helium is an inert gas, can be used without special precautions for security and, moreover, it is needed as a damping gas in the trap. A disadvantage of helium is the high viscosity resulting in long GC run times. In this work hydrogen was tested as an alternative carrier gas for GC in performing GC/MS analyses. A hydrogen generator was used as a safe source of hydrogen gas. It is demonstrated that hydrogen can be used as a carrier gas for the gas chromatograph in combination with helium as make-up gas for the trap. The analysis time was thus shortened and the chromatographic performance was optimized. Although hydrogen has proven useful as a carrier gas in gas chromatography coupled to standard detectors such as ECD or FID, its use is not mentioned extensively in the literature concerning gas chromatography-ion trap mass spectrometry. However, it is worth considering as a possibility because of its chromatographic advantages and its advantageous price when using a hydrogen generator. Copyright 2001 John Wiley & Sons, Ltd.

  1. Gas-liquid annular flow in vertical circular tubes with liquid penetrated in nucleus

    International Nuclear Information System (INIS)

    Nogueira, E.; Brum, N.C.L.; Cotta, R.M.

    1990-01-01

    A semi-analytical model is proposed for fully developed upward gas-liquid annular flow inside vertical circular tubes, by utilizing wall-known turbulence algebraic models for single-phase flows, within both streams, combined with empirical correlations for the gas-liquid interface friction factor. Direct integration of the associated momentum equations provide the velocity distribution for each phase, as well as overall quantities of practical interest such as liquid film thickness and pressure gradient. The effects of liquid droplets entrainment in the gas is specialized empirical correlations. Extensive comparisons with experimental results are made in order to demonstrate the consistency of the proposed model. (author)

  2. Chemical characterization of neonicotinoids in surface waters by high performance liquid chromatography with Tandem Mass Spectrometry (HPLC MS/MS)

    International Nuclear Information System (INIS)

    Amaral, Priscila Oliveira

    2017-01-01

    The present study aimed to develop a method for the determination and validation of a method for the identification and quantification of Neonicotinoids in surface waters collected in the Bauru region, in the state of São Paulo. The analytical techniques studied for the development of this method were the high performance liquid chromatography with tandem mass spectrometry (HPLC - MS / MS), gas chromatography with mass spectrometry (GC / MS) and gas chromatography with electron capture detector (GC / ECD). The class of pesticides Neonicotinoids was chosen for this work because it is related to a sudden disappearance of bees in colonies around the world. This phenomenon is known as Colony Collapse Disorder (CCD) and it is characterized by a rapid loss in the population of adult bees. The Neonicotinoids used in this study were the compounds Clothianidin, Imidacloprid and Thiamethoxam which were banned in their use as pesticides in Europe by Implementing Regulation No. 540/2011. The samples were concentrated using solid phase extraction (SPE) and liquid liquid extraction (LLE) techniques and injected into HPLC-MS / MS, GC / MS and GC / ECD. The GC / ECD and GC / MS techniques were not satisfactory for determination in the water matrix because the detection limit (10 mg L -1 ) is above the maximum allowed by the US Environmental Protection Agency (0.6 μg L -1 ). The HPLC - MS / MS technique using the multiple reaction monitoring (MRM) proved to be adequate for this study because it obtained quantification limits between 5.89 and 8.06 μg L -1 and a linearity between 0.9963 and 0.9999 for the three compounds. (author)

  3. Thermal reactor. [liquid silicon production from silane gas

    Science.gov (United States)

    Levin, H.; Ford, L. B. (Inventor)

    1982-01-01

    A thermal reactor apparatus and method of pyrolyticaly decomposing silane gas into liquid silicon product and hydrogen by-product gas is disclosed. The thermal reactor has a reaction chamber which is heated well above the decomposition temperature of silane. An injector probe introduces the silane gas tangentially into the reaction chamber to form a first, outer, forwardly moving vortex containing the liquid silicon product and a second, inner, rewardly moving vortex containing the by-product hydrogen gas. The liquid silicon in the first outer vortex deposits onto the interior walls of the reaction chamber to form an equilibrium skull layer which flows to the forward or bottom end of the reaction chamber where it is removed. The by-product hydrogen gas in the second inner vortex is removed from the top or rear of the reaction chamber by a vortex finder. The injector probe which introduces the silane gas into the reaction chamber is continually cooled by a cooling jacket.

  4. Tuning ionic liquids for high gas solubility and reversible gas sorption

    DEFF Research Database (Denmark)

    Huang, Jun; Riisager, Anders; Berg, Rolf W.

    2008-01-01

    New 1,1,3,3-tetramethylguanidinium-based ionic liquids have been synthesized and their ability to reversibly absorb gaseous sulfur dioxide and ammonia investigated. It was found that up to 2 moles of gas at 1 bar could be absorbed per mole of ionic liquid at room temperature and almost completely...... a moderate association between gas and liquid, which also could be confirmed by Raman and UV–vis spectroscopy on the gas-saturated (1 bar) ionic liquids. Knowledge of gas solubilities and the reversible gas absorption capacity of ionic liquids are believed to have importance for their possible application...... as reaction media for, e.g. catalytic processes involving gaseous reactants, and as absorbents in gas separation processes....

  5. Preparation and chromatographic evaluation of a newly designed steviol glycoside modified-silica stationary phase in hydrophilic interaction liquid chromatography and reversed phase liquid chromatography.

    Science.gov (United States)

    Liang, Tu; Fu, Qing; Shen, Aijin; Wang, Hui; Jin, Yu; Xin, Huaxia; Ke, Yanxiong; Guo, Zhimou; Liang, Xinmiao

    2015-04-03

    A diterpene glycoside compound, rebaudioside A (commonly abbreviated as RA), was immobilized onto porous silica surface through "thiol-ene" click chemistry strategy. The successful immobilization of the RA on the silica support was confirmed by FT-IR and elemental analysis. Chromatographic characteristics of the new stationary phase, named Click TE-RA, were evaluated by a set of diverse analytes such as carbohydrates, nucleosides, and organic acids in hydrophilic interaction liquid chromatography (HILIC) mode. The effects of water content, buffer pH and concentration were investigated and a typical HILIC retention feature of Click TE-RA was observed at high organic modifier content. The Click TE-RA stationary phase was further studied by a series of glycoside compounds. Tunable retention mechanisms from hydrophilic to hydrophobic interactions were observed. Separation of very polar compounds including oligosaccharides, nucleic acid bases and nucleosides using Click TE-RA in HILIC mode was successfully accomplished. In addition, separation of saponins both in HILIC and reversed-phase liquid chromatography (RPLC) modes was performed, demonstrating the presence of orthogonality between two different modes on Click TE-RA column. The multiple interactions induced by polar sugar group and hydrophobic aglycone group allowed this Click TE-RA to serve as a multi-mode stationary phase in two-dimensional liquid chromatography. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Investigation of surface properties of physico-chemically modified natural fibres using inverse gas chromatography

    CSIR Research Space (South Africa)

    Cordeiro, N

    2011-01-01

    Full Text Available Inverse gas chromatography (IGC) is a suitable method to determine surface energy of natural fibres when compared to wetting techniques. In the present study, the surface properties of raw and modified lignocellulosic fibres have been investigated...

  7. Analysis of chemical signals in red fire ants by gas chromatography and pattern recognition techniques

    Science.gov (United States)

    The combination of gas chromatography and pattern recognition (GC/PR) analysis is a powerful tool for investigating complicated biological problems. Clustering, mapping, discriminant development, etc. are necessary to analyze realistically large chromatographic data sets and to seek meaningful relat...

  8. ENVIRONMENTAL ANALYSIS BY AB INITIO QUANTUM MECHANICAL COMPUTATION AND GAS CHROMATOGRAPHY/FOURIER TRANSFORM INFRARED SPECTROMETRY.

    Science.gov (United States)

    Computational chemistry, in conjunction with gas chromatography/mass spectrometry/Fourier transform infrared spectrometry (GC/MS/FT-IR), was used to tentatively identify seven tetrachlorobutadiene (TCBD) isomers detected in an environmental sample. Computation of the TCBD infrare...

  9. Acid Gas - Diethanolamine Vapor - Liquid Equilibrium Data by Fourier Transform Infrared Spectroscopy.

    Science.gov (United States)

    Frazier, Richard Eugene

    A new apparatus for establishing vapor-liquid equilibrium (VLE) and a new method for measuring VLE data on acid gas - diethanolamine (DEA) systems are described. The acid gases studied were carbon dioxide (CO_2 ) and hydrogen sulfide (H_2S). The capability of the apparatus to establish an equilibrium was verified by reproducing data for CO_ {2}-water and H_2S -water systems. The new measurement method used Fourier transform infrared (FTIR) spectroscopy to analyze the gas composition without removing a vapor sample from the equilibrium equipment. Gas chromatography was used to analyze the liquid phase. The FTIR method eliminated the typical adsorption losses and subsequent errors resulting from the sampling and analysis of vapor compositions with low concentrations of hydrogen sulfide. Using the new method, preliminary VLE measurements have been made for a previously determined system using a single acid gas and an acid gas mixture over a 20 wt % DEA solution at 50^circ C. The CO_2 only system was measured over the partial pressure range of 0.1 to 0.0002 psia and liquid loadings from 0.2 to 0.008 moles of CO_2 per mole of DEA. The H _2S only system was measured over the partial pressure range from 0.8 psia to the lower limit of 0.01 psia and liquid loadings from 0.32 to 0.001 moles of H_2S per mole of DEA. Low partial pressure H_2S measurements deviated from literature VLE data and indicated that the equipment or methodology still needs to be refined. Acid gas mixture measurements were also incorrect but do illustrate that the method is viable for analyzing mixed acid gases and can surpass published, contemporary, VLE measurements determined by gas chromatography only. FTIR analysis of the liquid phase for ionic species was indeterminate. This work is the first stage in a continuing research effort. Equipment modifications are recommended to improve the lower detectable limit for hydrogen sulfide and carbon dioxide partial pressure measurements, to define a

  10. Determination of statin drugs in hospital effluent with dispersive liquid-liquid microextraction and quantification by liquid chromatography.

    Science.gov (United States)

    Martins, Ayrton F; Frank, Carla da S; Altissimo, Joseline; de Oliveira, Júlia A; da Silva, Daiane S; Reichert, Jaqueline F; Souza, Darliana M

    2017-08-24

    Statins are classified as being amongst the most prescribed agents for treating hypercholesterolaemia and preventing vascular diseases. In this study, a rapid and effective liquid chromatography method, assisted by diode array detection, was designed and validated for the simultaneous quantification of atorvastatin (ATO) and simvastatin (SIM) in hospital effluent samples. The solid phase extraction (SPE) of the analytes was optimized regarding sorbent material and pH, and the dispersive liquid-liquid microextraction (DLLME), in terms of pH, ionic strength, type and volume of extractor/dispersor solvents. The performance of both extraction procedures was evaluated in terms of linearity, quantification limits, accuracy (recovery %), precision and matrix effects for each analyte. The methods proved to be linear in the concentration range considered; the quantification limits were 0.45 µg L -1 for ATO and 0.75 µg L -1 for SIM; the matrix effect was almost absent in both methods and the average recoveries remained between 81.5-90.0%; and the RSD values were <20%. The validated methods were applied to the quantification of the statins in real samples of hospital effluent; the concentrations ranged from 18.8 µg L -1 to 35.3 µg L -1 for ATO, and from 30.3 µg L -1 to 38.5 µg L -1 for SIM. Since the calculated risk quotient was ≤192, the occurrence of ATO and SIM in hospital effluent poses a potential serious risk to human health and the aquatic ecosystem.

  11. Analysis of drugs of abuse in human plasma by dispersive liquid-liquid microextraction and high-performance liquid chromatography.

    Science.gov (United States)

    Fernández, P; Regenjo, M; Bermejo, A M; Fernández, A M; Lorenzo, R A; Carro, A M

    2015-04-01

    Opioids and cocaine are widely used at present, both for recreational purposes and as drugs of abuse. This raises the need to develop new analytical methods specifically designed for the simultaneous detection of several drugs of abuse in biological samples. In this work, dispersive liquid-liquid microextraction (DLLME) was assessed as a new sample treatment for the simultaneous extraction of morphine (MOR), 6-acetylmorphine (6AM), cocaine (COC), benzoylecgonine (BZE) and methadone (MET) from human plasma. Preliminary assays were done before developing an experimental design based on a Uniform Network Doehlert which allowed the optimum extraction conditions to be identified, namely: a volume of extractant solvent (chloroform) and dispersant solvent (acetonitrile) of 220 µl and 3.2 ml, respectively; 0.2 g of NaCl as a salting-out additive; pH 10.6 and ultrasound stirring for 3.5 min. The resulting extracts were analyzed by high-performance liquid chromatography with photodiode array detection (HPLC-PDA), using an XBridge® RP18 column (250 × 4.6 mm i.d., 5 µm particle size). Calibration graphs were linear over the concentration range 0.1-10 µg ml⁻¹, and detection limits ranged from 13.9 to 28.5 ng ml⁻¹. Precision calculated at three different concentration levels in plasma was included in the range 0.1-6.8% RSD. Recoveries of the five drugs were all higher than 84% on average. Finally the proposed method was successfully applied to 22 plasma samples from heroin, cocaine and/or methadone users, and the most frequently detected drug was benzoylecgonine, followed by methadone, cocaine and morphine. Copyright © 2014 John Wiley & Sons, Ltd.

  12. Bacterial Cell Wall Precursor Phosphatase Assays Using Thin-layer Chromatography (TLC) and High Pressure Liquid Chromatography (HPLC).

    Science.gov (United States)

    Pazos, Manuel; Otten, Christian; Vollmer, Waldemar

    2018-03-20

    Peptidoglycan encases the bacterial cytoplasmic membrane to protect the cell from lysis due to the turgor. The final steps of peptidoglycan synthesis require a membrane-anchored substrate called lipid II, in which the peptidoglycan subunit is linked to the carrier lipid undecaprenol via a pyrophosphate moiety. Lipid II is the target of glycopeptide antibiotics and several antimicrobial peptides, and is degraded by 'attacking' enzymes involved in bacterial competition to induce lysis. Here we describe two protocols using thin-layer chromatography (TLC) and high pressure liquid chromatography (HPLC), respectively, to assay the digestion of lipid II by phosphatases such as Colicin M or the LXG toxin protein TelC from Streptococcus intermedius . The TLC method can also monitor the digestion of undecaprenyl (pyro)phosphate, whereas the HPLC method allows to separate the di-, mono- or unphosphorylated disaccharide pentapeptide products of lipid II.

  13. Gas Separation Ability of the Liquid Bubble Film.

    Czech Academy of Sciences Publication Activity Database

    Řezníčková Čermáková, Jiřina; Petričkovič, Roman; Vejražka, Jiří; Setničková, Kateřina; Uchytil, Petr

    2016-01-01

    Roč. 166, JUN 22 (2016), s. 26-33 ISSN 1383-5866 Institutional support: RVO:67985858 Keywords : liquid film membrane * bubble * gas separation Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 3.359, year: 2016

  14. Lipidomic analysis of biological samples: Comparison of liquid chromatography, supercritical fluid chromatography and direct infusion mass spectrometry methods.

    Science.gov (United States)

    Lísa, Miroslav; Cífková, Eva; Khalikova, Maria; Ovčačíková, Magdaléna; Holčapek, Michal

    2017-11-24

    Lipidomic analysis of biological samples in a clinical research represents challenging task for analytical methods given by the large number of samples and their extreme complexity. In this work, we compare direct infusion (DI) and chromatography - mass spectrometry (MS) lipidomic approaches represented by three analytical methods in terms of comprehensiveness, sample throughput, and validation results for the lipidomic analysis of biological samples represented by tumor tissue, surrounding normal tissue, plasma, and erythrocytes of kidney cancer patients. Methods are compared in one laboratory using the identical analytical protocol to ensure comparable conditions. Ultrahigh-performance liquid chromatography/MS (UHPLC/MS) method in hydrophilic interaction liquid chromatography mode and DI-MS method are used for this comparison as the most widely used methods for the lipidomic analysis together with ultrahigh-performance supercritical fluid chromatography/MS (UHPSFC/MS) method showing promising results in metabolomics analyses. The nontargeted analysis of pooled samples is performed using all tested methods and 610 lipid species within 23 lipid classes are identified. DI method provides the most comprehensive results due to identification of some polar lipid classes, which are not identified by UHPLC and UHPSFC methods. On the other hand, UHPSFC method provides an excellent sensitivity for less polar lipid classes and the highest sample throughput within 10min method time. The sample consumption of DI method is 125 times higher than for other methods, while only 40μL of organic solvent is used for one sample analysis compared to 3.5mL and 4.9mL in case of UHPLC and UHPSFC methods, respectively. Methods are validated for the quantitative lipidomic analysis of plasma samples with one internal standard for each lipid class. Results show applicability of all tested methods for the lipidomic analysis of biological samples depending on the analysis requirements

  15. A gas chromatography-mass spectrometry method for the quantitation of clobenzorex.

    Science.gov (United States)

    Cody, J T; Valtier, S

    1999-01-01

    Drugs metabolized to amphetamine or methamphetamine are potentially significant concerns in the interpretation of amphetamine-positive urine drug-testing results. One of these compounds, clobenzorex, is an anorectic drug that is available in many countries. Clobenzorex (2-chlorobenzylamphetamine) is metabolized to amphetamine by the body and excreted in the urine. Following administration, the parent compound was detectable for a shorter time than the metabolite amphetamine, which could be detected for days. Because of the potential complication posed to the interpretation of amphetamin-positive drug tests following administration of this drug, the viability of a current amphetamine procedure using liquid-liquid extraction and conversion to the heptafluorobutyryl derivative followed by gas chromatography-mass spectrometry (GC-MS) analysis was evaluated for identification and quantitation of clobenzorex. Qualitative identification of the drug was relatively straightforward. Quantitative analysis proved to be a far more challenging process. Several compounds were evaluated for use as the internal standard in this method, including methamphetamine-d11, fenfluramine, benzphetamine, and diphenylamine. Results using these compounds proved to be less than satisfactory because of poor reproducibility of the quantitative values. Because of its similar chromatographic properties to the parent drug, the compound 3-chlorobenzylamphetamine (3-Cl-clobenzorex) was evaluated in this study as the internal standard for the quantitation of clobenzorex. Precision studies showed 3-Cl-clobenzorex to produce accurate and reliable quantitative results (within-run relative standard deviations [RSDs] clobenzorex.

  16. Analysis of volatile compounds of Malaysian Tualang (Koompassia excelsa) honey using gas chromatography mass spectrometry.

    Science.gov (United States)

    Nurul Syazana, M S; Gan, S H; Halim, A S; Shah, Nurul Syazana Mohamad; Gan, Siew Hua; Sukari, Halim Ahmad

    2013-01-01

    The constituents of honey's volatile compounds depend on the nectar source and differ depending on the place of origin. To date, the volatile constituents of Tualang honey have never been investigated. The objective of this study was to analyze the volatile compounds in local Malaysian Tualang honey. A continuous extraction of Tualang honey using five organic solvents was carried out starting from non-polar to polar solvents and the extracted samples were analysed using gas chromatography-mass spectrometry (GC-MS). Overall, 35 volatile compounds were detected. Hydrocarbons constitute 58.5% of the composition of Tualang honey. Other classes of chemical compounds detected included acids, aldehydes, alcohols, ketones, terpenes, furans and a miscellaneous group. Methanol yielded the highest number of extracted compounds such as acids and 5-(Hydroxymethyl) furfural (HMF). This is the first study to describe the volatile compounds in Tualang honey. The use of a simple one tube, stepwise, non-thermal liquid-liquid extraction of honey is a advantageous as it prevents sample loss. Further research to test the clinical benefits of these volatile compounds is recommended.

  17. A fast, comprehensive screening method for doping agents in urine by gas chromatography-triple quadrupole mass spectrometry.

    Science.gov (United States)

    Van Eenoo, Peter; Van Gansbeke, Wim; De Brabanter, Nik; Deventer, Koen; Delbeke, Frans T

    2011-05-27

    The use of performance enhancing drugs in sports is prohibited. For the detection of misuse of such substances gas chromatography or liquid chromatography coupled to mass spectrometry are the most frequently used detection techniques. In this work the development and validation of a fast gas chromatography tandem mass spectrometric method for the detection of a wide range of doping agents is described. The method can determine 13 endogenous steroids (the steroid profile), 19-norandrosterone, salbutamol and 11-nor-Δ9-tetrahydrocannabinol.9carboxylic acid in the applicable ranges and to detect qualitatively over 140 substances in accordance with the minimum required performance levels of the World Anti-Doping Agency in 1ml of urine. The classes of substances included in the method are anabolic steroids, β2-agonists, stimulants, narcotics, hormone antagonists and modulators and beta-blockers. Moreover, using a short capillary column and hydrogen as a carrier gas the run time of the method is less than 8min. Copyright © 2010 Elsevier B.V. All rights reserved.

  18. New Potential Biomarker for Methasterone Misuse in Human Urine by Liquid Chromatography Quadrupole Time of Flight Mass Spectrometry.

    Science.gov (United States)

    Zhang, Jianli; Lu, Jianghai; Wu, Yun; Wang, Xiaobing; Xu, Youxuan; Zhang, Yinong; Wang, Yan

    2016-09-24

    In this study, methasterone urinary metabolic profiles were investigated by liquid chromatography quadrupole time of flight mass spectrometry (LC-QTOF-MS) in full scan and targeted MS/MS modes with accurate mass measurement. A healthy male volunteer was asked to take the drug and liquid-liquid extraction was employed to process urine samples. Chromatographic peaks for potential metabolites were hunted out with the theoretical [M - H](-) as a target ion in a full scan experiment and actual deprotonated ions were studied in targeted MS/MS experiment. Fifteen metabolites including two new sulfates (S1 and S2), three glucuronide conjugates (G2, G6 and G7), and three free metabolites (M2, M4 and M6) were detected for methasterone. Three metabolites involving G4, G5 and M5 were obtained for the first time in human urine samples. Owing to the absence of helpful fragments to elucidate the steroid ring structure of methasterone phase II metabolites, gas chromatography mass spectrometry (GC-MS) was employed to obtain structural information of the trimethylsilylated phase I metabolite released after enzymatic hydrolysis and the potential structure was inferred using a combined MS method. Metabolite detection times were also analyzed and G2 (18-nor-17β-hydroxymethyl-2α, 17α-dimethyl-androst-13-en-3α-ol-ξ-O-glucuronide) was thought to be new potential biomarker for methasterone misuse which can be detected up to 10 days.

  19. Gas-liquid transfer of aroma compounds during winemaking fermentations

    OpenAIRE

    Mouret, J. R.; Morakul, S.; Nicolle, P.; Athes, V.; Sablayrolles, J. M.

    2012-01-01

    We precisely monitored the production kinetics of 16 volatile carbon compounds corresponding to the predominant higher alcohols and esters produced during the alcoholic fermentation of wine using an online GC system. We studied the gas-liquid partitioning of isobutanol, isoamyl acetate and ethyl hexanoate and showed that CO2 stripping had no impact on the partition coefficient (k(i)). We formulated a predictive model for k(i) changes during the fermentation and calculated the gas-liquid balan...

  20. Pervaporation and Gas Separation with Supported Liquid Membranes.

    OpenAIRE

    Izák, Pavel

    2016-01-01

    The goal of this work is to combine the recent developments in the field of membrane technology, e.g. supported liquid membranes, pervaporation and gas separation with the use of ionic liquids (ILs) for providing novel solutions in downstream processing or process intensification.

  1. Buffer-Free High Performance Liquid Chromatography Method for ...

    African Journals Online (AJOL)

    Purpose: To develop and validate a simple, economical and reproducible high performance liquid chromatographic (HPLC) method for the determination of theophylline in pharmaceutical dosage forms. Method: Caffeine was used as the internal standard and reversed phase C-18 column was used to elute the drug and ...

  2. Application in pesticide analysis: Liquid chromatography - A review of the state of science for biomarker discovery and identification

    Science.gov (United States)

    Book Chapter 18, titled Application in pesticide analysis: Liquid chromatography - A review of the state of science for biomarker discovery and identification, will be published in the book titled High Performance Liquid Chromatography in Pesticide Residue Analysis (Part of the C...

  3. Hydrogen extraction from liquid lithium-lead alloy by gas-liquid contact method

    International Nuclear Information System (INIS)

    Xie Bo; Weng Kuiping; Hou Jianping; Yang Guangling; Zeng Jun

    2013-01-01

    Hydrogen extraction experiment from liquid lithium-lead alloy by gas-liquid contact method has been carried out in own liquid lithium-lead bubbler (LLLB). Experimental results show that, He is more suitable than Ar as carrier gas in the filler tower. The higher temperature the tower is, the greater hydrogen content the tower exports. Influence of carrier gas flow rate on the hydrogen content in the export is jagged, no obvious rule. Although the difference between experimental results and literature data, but it is feasible that hydrogen isotopes extraction experiment from liquid lithium-lead by gas-liquid contact method, and the higher extraction efficiency increases with the growth of the residence time of the alloy in tower. (authors)

  4. Ultrasonic nebulization extraction coupled with on-line gas chromatography for determination of trans-anethole in spices.

    Science.gov (United States)

    Wang, Lu; Liang, Yue; Wang, Ziming; Qu, Chenling; Li, Dan; Shi, Yuhua; Zhang, Hanqi

    2009-12-15

    Ultrasonic nebulization extraction (UNE) coupled with on-line gas chromatography (GC) was proposed for the determination of trans-anethole in fruits of Illicium verum Hook. f. and Foeniculum vulgare Mill. The extraction was performed in a common self-made extraction system. In the UNE the analyte was transferred and enriched from the solid sample to gas phase. The sample gas containing analyte obtained by UNE was introduced into the sampling loop with the purging gas (N(2)). And then the sample gas in the sampling loop was introduced into the GC column. Several experimental parameters of on-line UNE-GC, including sampling time, flow rate of purging gas, standstill time and temperature of tubing, were optimized. The calibration curve ranging from 0.05 to 1.5 mg g(-1) for determining the trans-anethole was obtained. The recoveries for determining trans-anethole are between 99.2% and 111.2% and RSDs are less than 8.3% when the UNE was applied. The analytes can rapidly be extracted and transferred from the solid sample to gas phase. The analytes in the gas phase are easier to be introduced into GC system than those in the solid and liquid phase. Compared with off-line systems, the proposed on-line system is more suitable to detect volatile compounds.

  5. The analysis of aqueous mixtures using liquid chromatography-electrospray mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Steven [Iowa State Univ., Ames, IA (United States)

    1999-02-12

    The focus of this dissertation is the use of chromatographic methods coupled with electrospray mass spectrometry (ES-MS) for the determination of both organic and inorganic compounds in aqueous solutions. The combination of liquid chromatography (LC) methods and ES-MS offers one of the foremost methods for determining compounds in complex aqueous solutions. In this work, LC-ES-MS methods are devised using ion exclusion chromatography, reversed phase chromatography, and ion exchange chromatography, as well as capillary electrophoresis (CE). For an aqueous sample, these LC-ES-MS and CE-ES-MS techniques require no sample preparation or analyte derivatization, which makes it possible to observe a wide variety of analytes as they exist in solution. The majority of this work focuses on the use of LC-ES-MS for the determination of unknown products and intermediates formed during electrochemical incineration (ECI), an experimental waste remediation process. This report contains a general introduction to the project and the general conclusions. Four chapters have been removed for separate processing. Titles are: Chapter 2: Determination of small carboxylic acids by ion exclusion chromatography with electrospray mass spectrometry; Chapter 3: Electrochemical incineration of benzoquinone in aqueous media using a quaternary metal oxide electrode in the absence of a soluble supporting electrolyte; Chapter 4: The determination of electrochemical incineration products of 4-chlorophenol by liquid chromatography-electrospray mass spectrometry; and Chapter 5: Determination of small carboxylic acids by capillary electrophoresis with electrospray mass spectrometry.

  6. Hydrophilic Interaction Liquid Chromatography: ESI–MS/MS of Plasmalogen Phospholipids from Pectinatus Bacterium

    Czech Academy of Sciences Publication Activity Database

    Řezanka, Tomáš; Siřišťová, L.; Matoulková, D.; Sigler, Karel

    2011-01-01

    Roč. 46, č. 8 (2011), 765-780 ISSN 0024-4201 R&D Projects: GA MŠk 1M0570 Institutional research plan: CEZ:AV0Z50200510 Keywords : Plasmalogens * Pectinatus * Liquid chromatography-electrospray tandem mass spectrometry Subject RIV: EE - Microbiology, Virology Impact factor: 2.129, year: 2011

  7. Quantification and validation of ertapenem using a liquid chromatography-tandem mass spectrometry method

    NARCIS (Netherlands)

    van Rijn, S.P.; Wessels, A.M.A.; Greijdanus, B.; Touw, D.J.; Alffenaar, J.W.C.

    Ertapenem, a carbapenem, relies on time-dependent killing. Therapeutic drug monitoring (TDM) should be considered, when ertapenem is used in specific populations, to achieve optimal bactericidal activity and optimize drug-dosing regimens. No validated liquid chromatography-tandem mass spectrometry

  8. Determination of Bedaquiline in Human Serum Using Liquid Chromatography-Tandem Mass Spectrometry

    NARCIS (Netherlands)

    Alffenaar, Jan-Willem C.; Bolhuis, Mathieu; van Hateren, Kai; Sturkenboom, Marieke; Akkerman, Onno; de Lange, Wiel; Greijdanus, Ben; van der Werf, Tjip; Touw, Daan

    Bedaquiline, a diarylquinoline for the treatment of multidrug-resistant tuberculosis (TB), relies on exposure-dependent killing. As data on drug exposure in specific populations are scarce, pharmacokinetic studies may be of interest. No simple and robust validated liquid chromatography-tandem mass

  9. Alternative sample-introduction technique to avoid breakthrough in gradient-elution liquid chromatography of polymers

    NARCIS (Netherlands)

    Reingruber, E.; Bedani, F.; Buchberger, W.; Schoenmakers, P.

    2010-01-01

    Gradient-elution liquid chromatography (GELC) is a powerful tool for the characterization of synthetic polymers. However, gradient-elution chromatograms often suffer from breakthrough phenomena. Breakthrough can be averted by using a sample solvent as weak as the mobile phase. However, this approach

  10. Deformation and degradation of polymers in ultra-high-pressure liquid chromatography

    NARCIS (Netherlands)

    Uliyanchenko, E.; van der Wal, S.; Schoenmakers, P.J.

    2011-01-01

    Ultra-high-pressure liquid chromatography (UHPLC) using columns packed with sub-2 μm particles has great potential for separations of many types of complex samples, including polymers. However, the application of UHPLC for the analysis of polymers meets some fundamental obstacles. Small particles

  11. Determination of Peroxide-Based Explosives Using Liquid Chromatography with On-Line Infrared Detection

    NARCIS (Netherlands)

    Schulte-Ladbeck, Rasmus; Edelmann, Andrea; Quintas, Guillermo; Lendl, Bernhard; Karst, U.

    2006-01-01

    A nondestructive analytical method for peroxide-based explosives determination in solid samples is described. Reversed-phase high-performance liquid chromatography in combination with on-line Fourier transform infrared (FT-IR) detection is used for the analysis of triacetonetriperoxide (TATP) and

  12. Arsenic speciation by liquid chromatography coupled with ionspray tandem mass spectrometry

    DEFF Research Database (Denmark)

    Corr, J. J.; Larsen, Erik Huusfeldt

    1996-01-01

    Ionspray mass spectrometry, a well established organic analysis technique, has been coupled to high-performance liquid chromatography for speciation of organic arsenic compounds, The ionspray source and differentially pumped interface of the mass spectrometer were operated in dual modes for eleme...

  13. Characterization of typical chemical background interferences in atmospheric pressure ionization liquid chromatography-mass spectrometry

    NARCIS (Netherlands)

    Guo, Xinghua; Bruins, Andries P.; Covey, Thomas R.

    2006-01-01

    The structures and origins of typical chemical background noise ions in positive atmospheric pressure ionization liquid chromatography/mass spectrometry (API LC/MS) are investigated and summarized in this study. This was done by classifying chemical background ions using precursor and product ion

  14. Separation of enzymically active bovine cytochrome c oxidase monomers and dimers by high performance liquid chromatography

    NARCIS (Netherlands)

    Hakvoort, T. B.; Sinjorgo, K. M.; van Gelder, B. F.; Muijsers, A. O.

    1985-01-01

    The aggregation state of two types of bovine heart cytochrome c oxidase preparations in the presence of laurylmaltoside was investigated by high performance liquid chromatography in two buffers of ionic strengths of 388 mM and 45 mM, respectively. At high ionic strength, it was found that the Fowler

  15. High-performance liquid chromatography determination of dapsone, monoacetyldapsone, and pyrimethamine in filter paper blood spots

    DEFF Research Database (Denmark)

    Rønn, A M; Lemnge, M M; Angelo, H R

    1995-01-01

    A high-performance liquid chromatography method for the simultaneous analysis of dapsone (DDS), the major metabolite of DDS, monoacetyldapsone (MADDS), and pyrimethamine (PYR) was modified for capillary blood samples obtained by finger prick and dried on filter paper. Limit of quantitation using...

  16. Benzoin Condensation: Monitoring a Chemical Reaction by High-Pressure Liquid Chromatography

    Science.gov (United States)

    Bhattacharya, Apurba; Purohit, Vikram C.; Bellar, Nicholas R.

    2004-01-01

    High-pressure liquid chromatography (HPLC) is the preferred method of separating a variety of materials in complex mixtures such as pharmaceuticals, polymers, soils, food products and biological fluids and is also considered to be a powerful analytical tool in both academia and industry. The use of HPLC analysis as a means of monitoring and…

  17. Determination of organophosphorus acids by thermo-spray liquid chromatography-mass spectrometry

    NARCIS (Netherlands)

    Wils, E.R.J.; Hulst, A.G.

    1988-01-01

    The determination of thirteen organophosphorus acids, hydrolysis products of nerve agents and pesticides, by a combination of ion-pair liquid chromatography on a reversed-phase C18 column and thermospray mass spectrometry was investigated. Ammonium acetate and three tetraalkylammonium salts with

  18. Extraction and Purification of Glucoraphanin by Preparative High-Performance Liquid Chromatography (HPLC)

    Science.gov (United States)

    Lee, Iris; Boyce, Mary C.

    2011-01-01

    A student activity that focuses on the isolation of glucoraphanin from broccoli using preparative high-performance liquid chromatography (HPLC) is presented here. Glucoraphanin is a glucosinolate, whose byproducts are known to possess anticancer properties. It is present naturally at high levels in broccoli and other "Brassica" vegetables. This…

  19. A liquid chromatography-mass spectrometry-based metabolome database for tomato

    NARCIS (Netherlands)

    Moco, S.I.A.; Bino, R.J.; Vorst, O.F.J.; Verhoeven, H.A.; Groot, de J.C.W.; Beek, van T.A.; Vervoort, J.J.M.; Vos, de C.H.

    2006-01-01

    For the description of the metabolome of an organism, the development of common metabolite databases is of utmost importance. Here we present the Metabolome Tomato Database (MoTo DB), a metabolite database dedicated to liquid chromatography-mass spectrometry (LC-MS)- based metabolomics of tomato

  20. High resolution full scan liquid chromatography mass spectrometry comprehensive screening in sports antidoping urine analysis

    NARCIS (Netherlands)

    Abushareeda, Wadha; Vonaparti, Ariadni; Saad, Khadija Al; Almansoori, Moneera; Meloug, Mbarka; Saleh, Amal; Aguilera, Rodrigo; Angelis, Yiannis; Horvatovich, Peter L.; Lommen, Arjen; Alsayrafi, Mohammed; Georgakopoulos, Costas

    2018-01-01

    The aim of this paper is to present the development and validation of a high-resolution full scan (HR-FS) electrospray ionization (ESI) liquid chromatography coupled to quadrupole Orbitrap mass spectrometer (LC/Q/Orbitrap MS) platform for the screening of prohibited substances in human urine