WorldWideScience

Sample records for gas distribution pipe

  1. PVC pipes in gas distribution: still going strong!

    OpenAIRE

    Hermkens, Rene; Wolters, Mannes; Weller, Jeroen; Visser, Roy; Davidovski, Z.; Belloir, P.; Fumire, J.

    2008-01-01

    In the Netherlands (impact-modified) PVC is the preferred material for low-pressure (30 and 100 mbar) gas distribution systems. More than 50% of the total length (about 122,000 km) of this system is rigid PVC or impact-modified PVC. The installation of rigid PVC (uPVC) pipelines started about 50 years ago. Presently, about 22,500 km of rigid PVC is still in operation. In this paper the good experiences with rigid PVC gas distribution systems in the Netherlands will be illustrated by results o...

  2. One-Way Flow of a Rarefied Gas Induced in a Circular Pipe with a Periodic Temperature Distribution

    National Research Council Canada - National Science Library

    Aoki, K

    2000-01-01

    The steady behavior of a rarefied gas in a circular pipe with a saw-like temperature distribution increasing and decreasing periodically in the direction of the pipe axis is investigated numerically...

  3. PVC pipes in gas distribution: still going strong!

    NARCIS (Netherlands)

    Hermkens, Rene; Wolters, Mannes; Weller, Jeroen; Visser, Roy; Davidovski, Z.; Belloir, P.; Fumire, J.

    2008-01-01

    In the Netherlands (impact-modified) PVC is the preferred material for low-pressure (30 and 100 mbar) gas distribution systems. More than 50% of the total length (about 122,000 km) of this system is rigid PVC or impact-modified PVC. The installation of rigid PVC (uPVC) pipelines started about 50

  4. Gas lensing in a heated spinning pipe

    CSIR Research Space (South Africa)

    Mafusire, C

    2006-07-01

    Full Text Available When a heated pipe is rotated, the dynamics of the gas inside exhibit properties reminiscent of a solid-state positive lens. The properties are a result of a parabolic distribution of refractive index in the pipe which is caused by mixing of hot...

  5. Spinning pipe gas lens revisited

    CSIR Research Space (South Africa)

    Mafusire, C

    2008-01-01

    Full Text Available , there is little information on optical phase aberrations and no study to date on the propagation parameters of the laser beam, but has rather remained rooted in the domain of ray optics. Researchers revisit the spinning pipe gas lens in this paper with new...

  6. Polymer pipes for distributing mixtures of hydrogen and natural gas. Evolution of their transport and mechanical properties after an ageing under an hydrogen environment

    Energy Technology Data Exchange (ETDEWEB)

    Klopffer, Marie-Helene [IFP (France); Berne, Philippe [CEA (France); Castagnet, Sylvie [ENSMA (France); Weber, Mathilde [Air Liquide (Canada); Hochstetter, Gilles [Arkema (France); Espuche, Eliane [INSA Lyon (France)

    2010-07-01

    With the development of hydrogen as an energy vector, its delivery and transport from the production site to the end user remains an issue. Indeed, the key challenge to overcome is the high hydrogen permeation through existing polymer infrastructures used for natural gas distribution (Polyethylene pipes, components as connecting parts). This high flow rate of hydrogen through polymer has to be taken into account for safety and economical requirements. This 3-year project investigates pure hydrogen gas and mixtures (20% CH4 - 80% H2) in pipelines made of engineering polymers to develop and assess material solutions to cope with today problems for H2 distribution. Materials such as polyethylene (PE100) and polyamide 11 (PA11) have been studied. PE100 is considered as a reference material as it is used today in natural gas distribution pipes. PA11 should allow a higher operating pressure combined with better gas-barrier performances. Test benches and protocols for testing materials in terms of mechanical and barrier properties were first developed. The materials have then been studied in terms of barrier, mechanical properties and on a microstructural point of view. The properties of the raw material and samples after ageing in presence of hydrogen in various conditions were compared to assess the long term behaviour in service. These results as well as the comparison between PA11 and PE are presented. (orig.)

  7. Development of Innovating Materials for Distributing Mixtures of Hydrogen and Natural Gas. Study of the Barrier Properties and Durability of Polymer Pipes

    Directory of Open Access Journals (Sweden)

    Klopffer Marie-Hélène

    2015-02-01

    Full Text Available With the growing place taken by hydrogen, a question still remains about its delivery and transport from the production site to the end user by employing the existing extensive natural gas pipelines. Indeed, the key challenge is the significant H2 permeation through polymer infrastructures (PolyEthylene (PE pipes, components such as connecting parts. This high flow rate of H2 through PE has to be taken into account for safety and economic requirements. A 3-year project was launched, the aim of which was to develop and assess material solutions to cope with present problems for hydrogen gas distribution and to sustain higher pressure compared to classical high density polyethylene pipe. This project investigated pure hydrogen gas and mixtures with natural gas (20% of CH4 and 80% of H2 in pipelines with the aim to select engineering polymers which are more innovative than polyethylene and show outstanding properties, in terms of permeation, basic mechanical tests but also more specific characterizations such as long term ageing and behaviour. The adequate benches, equipments and scientific approach for materials testing had been developed and validated. In this context, the paper will focus on the evaluation of the barrier properties of 3 polymers (PE, PA11 and PAHM. Experiments were performed for pure H2 and CH4 and also in the presence of mixtures of hydrogen and natural gas in order to study the possible mixing effects of gases. It will report some round-robin tests that have been carried out. Secondly, by comparing data obtained on film, polymer membrane and on pipe section, the influence of the polymer processing will be studied. Innovative multilayers systems will be proposed and compared on the basis of the results obtained on monolayer systems. Finally, the evolution of the transport properties of the studied polymers with an ageing under representative service conditions will be discussed.

  8. Residual lifetime assessment of uPVC gas pipes

    OpenAIRE

    Visser, HA

    2010-01-01

    The Dutch gas distribution network consists of about 20% (22,500 km) of unplasticised poly(vinyl chloride) (uPVC) pipes, most of which have been installed from the mid-sixties up to the mid-seventies of the previous century and have been in service ever since. Replacing the uPVC gas pipes exactly after the specified service lifetime of 50 years will lead to a costly and extremely labour intensive project in the next decade. Postponing the replacement is only an option when it can be done with...

  9. Numerical simulation for gas-liquid two-phase flow in pipe networks

    International Nuclear Information System (INIS)

    Li Xiaoyan; Kuang Bo; Zhou Guoliang; Xu Jijun

    1998-01-01

    The complex pipe network characters can not directly presented in single phase flow, gas-liquid two phase flow pressure drop and void rate change model. Apply fluid network theory and computer numerical simulation technology to phase flow pipe networks carried out simulate and compute. Simulate result shows that flow resistance distribution is non-linear in two phase pipe network

  10. 46 CFR 154.910 - Inert gas piping: Location.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Inert gas piping: Location. 154.910 Section 154.910 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SAFETY... Atmospheric Control in Cargo Containment Systems § 154.910 Inert gas piping: Location. Inert gas piping must...

  11. Venting of gas deflagrations through relief pipes

    OpenAIRE

    Ferrara, Gabriele

    2006-01-01

    Vent devices for gas and dust explosions are often ducted to safety locations by means of relief pipes for the discharge of hot combustion products or blast waves (NFPA 68, 2002). The presence of the duct is likely to increase the severity of the explosion with respect to simply vented vessels posing a problem for the proper design of this venting configuration. The phenomenology of the vented explosion is complicated as the interaction of combustion in the duct with primary combustion in...

  12. CFD model of a spinning pipe gas lens

    CSIR Research Space (South Africa)

    Snedden, Glen C

    2006-07-01

    Full Text Available Slides on: Spinning Pipe Gas Lens; Focal Length; Refractive Index; Gas Dynamics; Guess at the gas dynamics; Density Profile; Flow Profile; Rosby Waves; Rayleigh–Taylor Instabilities...

  13. Corroded scale analysis from water distribution pipes

    Directory of Open Access Journals (Sweden)

    Rajaković-Ognjanović Vladana N.

    2011-01-01

    Full Text Available The subject of this study was the steel pipes that are part of Belgrade's drinking water supply network. In order to investigate the mutual effects of corrosion and water quality, the corrosion scales on the pipes were analyzed. The idea was to improve control of corrosion processes and prevent impact of corrosion on water quality degradation. The instrumental methods for corrosion scales characterization used were: scanning electron microscopy (SEM, for the investigation of corrosion scales of the analyzed samples surfaces, X-ray diffraction (XRD, for the analysis of the presence of solid forms inside scales, scanning electron microscopy (SEM, for the microstructural analysis of the corroded scales, and BET adsorption isotherm for the surface area determination. Depending on the composition of water next to the pipe surface, corrosion of iron results in the formation of different compounds and solid phases. The composition and structure of the iron scales in the drinking water distribution pipes depends on the type of the metal and the composition of the aqueous phase. Their formation is probably governed by several factors that include water quality parameters such as pH, alkalinity, buffer intensity, natural organic matter (NOM concentration, and dissolved oxygen (DO concentration. Factors such as water flow patterns, seasonal fluctuations in temperature, and microbiological activity as well as water treatment practices such as application of corrosion inhibitors can also influence corrosion scale formation and growth. Therefore, the corrosion scales found in iron and steel pipes are expected to have unique features for each site. Compounds that are found in iron corrosion scales often include goethite, lepidocrocite, magnetite, hematite, ferrous oxide, siderite, ferrous hydroxide, ferric hydroxide, ferrihydrite, calcium carbonate and green rusts. Iron scales have characteristic features that include: corroded floor, porous core that contains

  14. Thermal Analysis of the Divertor Primary Heat Transfer System Piping During the Gas Baking Process

    Energy Technology Data Exchange (ETDEWEB)

    Yoder Jr, Graydon L [ORNL; Harvey, Karen [ORNL; Ferrada, Juan J [ORNL

    2011-02-01

    A preliminary analysis has been performed examining the temperature distribution in the Divertor Primary Heat Transfer System (PHTS) piping and the divertor itself during the gas baking process. During gas baking, it is required that the divertor reach a temperature of 350 C. Thermal losses in the piping and from the divertor itself require that the gas supply temperature be maintained above that temperature in order to ensure that all of the divertor components reach the required temperature. The analysis described in this report was conducted in order to estimate the required supply temperature from the gas heater.

  15. Suggestions to leak prevention in Fortaleza's natural gas piping system; Sugestoes para a prevencao de vazamentos de gas natural canalizado na regiao metropolitana de Fortaleza

    Energy Technology Data Exchange (ETDEWEB)

    Teles, Marcus de Barros [Agencia Reguladora de Servicos Publicos Delegados do Estado do Ceara (ARCE), Fortaleza, CE (Brazil)

    2004-07-01

    Leaks are the bigger problem in health, safety and environmental when the subject is gas distribution piping systems. Specially in high density human regions, like in the majority districts of Fortaleza, safety have to be the higher priority to the gas company responsible for the gas distribution piping systems. Leaks are able to cause accidents or incidents, depending on the circumstances which they happen. In order to be control the situation and overcome the luck factor, leaks must be previously avoided by the application of some security requirements. This paper present some suggestions to natural gas leak prevention in the Fortaleza's metropolitan region pipeline systems. First, the piping systems are analysed, observing the risk regions. Then, safety actions and basic requirements to avoid pipe corrosion are presented in order to improve safety in the gas distribution piping systems of Fortaleza's metropolitan region. (author)

  16. Noncondensable gas accumulation phenomena in nuclear power plant piping

    International Nuclear Information System (INIS)

    Yamamoto, Yasushi; Aoki, Kazuyoshi; Sato, Teruaki; Shida, Akira; Ichikawa, Nagayoshi; Nishikawa, Akira; Inagaki, Tetsuhiko

    2011-01-01

    In the case of the boiling water reactor, hydrogen and oxygen slightly exist in the main steam, because these noncondensable gases are generated by the radiolytic decomposition of the reactor water. BWR plants have taken measures to prevent noncondensable gas accumulation. However, in 2001, the detonation of noncondensable gases occurred at Hamaoka-1 and Brunsbuttel, resulting in ruptured piping. The accumulation phenomena of noncondensable gases in BWR closed piping must be investigated and understood in order to prevent similar events from occurring in the future. Therefore, an experimental study on noncondensable gas accumulation was carried out. The piping geometries for testing were classified and modeled after the piping of actual BWR plants. The test results showed that 1) noncondensable gases accumulate in vertical piping, 2) it is hard for noncondensable gases to accumulate in horizontal piping, and 3) noncondensable gases accumulate under low-pressure conditions. A simple accumulation analysis method was proposed. To evaluate noncondensable gas accumulation phenomena, the three component gases were treated as a mixture. It was assumed that the condensation amount of the vapor is small, because the piping is certainly wrapped with heat insulation material. Moreover, local thermal equilibrium was assumed. This analysis method was verified using the noncondensable gas accumulation test data on branch piping with a closed top. Moreover, an experimental study on drain trap piping was carried out. The test results showed that the noncondensable gases dissolved in the drain water were discharged from the drain trap, and Henry's law could be applied to evaluate the amount of dissolved noncondensable gases in the drain water. (author)

  17. Startup analysis for a high temperature gas loaded heat pipe

    Science.gov (United States)

    Sockol, P. M.

    1973-01-01

    A model for the rapid startup of a high-temperature gas-loaded heat pipe is presented. A two-dimensional diffusion analysis is used to determine the rate of energy transport by the vapor between the hot and cold zones of the pipe. The vapor transport rate is then incorporated in a simple thermal model of the startup of a radiation-cooled heat pipe. Numerical results for an argon-lithium system show that radial diffusion to the cold wall can produce large vapor flow rates during a rapid startup. The results also show that startup is not initiated until the vapor pressure p sub v in the hot zone reaches a precise value proportional to the initial gas pressure p sub i. Through proper choice of p sub i, startup can be delayed until p sub v is large enough to support a heat-transfer rate sufficient to overcome a thermal load on the heat pipe.

  18. The spatial distribution of pollutants in pipe-scale of large-diameter pipelines in a drinking water distribution system

    International Nuclear Information System (INIS)

    Liu, Jingqing; Chen, Huanyu; Yao, Lingdan; Wei, Zongyuan; Lou, Liping; Shan, Yonggui; Endalkachew, Sahle-Demessie; Mallikarjuna, Nadagouda; Hu, Baolan; Zhou, Xiaoyan

    2016-01-01

    Highlights: • First investigating the spatial distribution of pollutants in pipe-scale. • Spatial distribution of heavy metals indicated their sources were different. • Three main factors effete the distribution of pollutants. • Organic deposits mainly included microbial and microalgae metabolites. - Abstract: In large-diameter drinking water pipelines, spatial differences in hydraulic and physiochemical conditions may also result in spatial variations in pipe corrosion, biofilm growth and pollutant accumulation. In this article, the spatial distributions of various metals and organic contaminants in two 19-year-old grey cast iron pipes which had an internal diameter of 600 mm (DN600), were investigated and analyzed by Atomic Absorption Spectrometry, Gas Chromatography–Mass Spectrometry, Energy Dispersive Spectrometer, X-ray Diffraction, etc. The spatial distribution of heavy metals varied significantly across the pipe section, and iron, manganese, lead, copper, and chromium were highest in concentration in the upper portion pipe-scales. However, the highest aluminum and zinc content was detected in the lower portion pipe-scales. Apart from some common types of hydrocarbons formed by microbial metabolites, there were also some microalgae metabolites and exogenous contaminants accumulated in pipe-scale, which also exhibited high diversity between different spatial locations. The spatial distributions of the physical and chemical properties of pipe-scale and contaminants were quite different in large-diameter pipes. The finding put forward higher requirements on the research method about drinking water distribution system chemical safety. And the scientific community need understand trend and dynamics of drinking water pipe systems better.

  19. The spatial distribution of pollutants in pipe-scale of large-diameter pipelines in a drinking water distribution system

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jingqing [College of Engineering and Architecture, Zhejiang University, Hangzhou 310058 (China); Chen, Huanyu [College of Environmental and Resource Sciences, Zhejiang University, Hangzhou 310058 (China); Binhai Industrial Technology Research Institute of Zhejiang University, Tianjin 300000 (China); Yao, Lingdan; Wei, Zongyuan [College of Environmental and Resource Sciences, Zhejiang University, Hangzhou 310058 (China); Lou, Liping, E-mail: loulp@zju.edu.cn [College of Environmental and Resource Sciences, Zhejiang University, Hangzhou 310058 (China); Shan, Yonggui; Endalkachew, Sahle-Demessie; Mallikarjuna, Nadagouda [Environmental Protection Agency, Office of Research and Development, NRMRL, Cincinnati, OH 45220 (United States); Hu, Baolan [College of Environmental and Resource Sciences, Zhejiang University, Hangzhou 310058 (China); Zhou, Xiaoyan [Shaoxing Water Environmental Science Institute Co. Ltd, Zhejiang 312000 (China)

    2016-11-05

    Highlights: • First investigating the spatial distribution of pollutants in pipe-scale. • Spatial distribution of heavy metals indicated their sources were different. • Three main factors effete the distribution of pollutants. • Organic deposits mainly included microbial and microalgae metabolites. - Abstract: In large-diameter drinking water pipelines, spatial differences in hydraulic and physiochemical conditions may also result in spatial variations in pipe corrosion, biofilm growth and pollutant accumulation. In this article, the spatial distributions of various metals and organic contaminants in two 19-year-old grey cast iron pipes which had an internal diameter of 600 mm (DN600), were investigated and analyzed by Atomic Absorption Spectrometry, Gas Chromatography–Mass Spectrometry, Energy Dispersive Spectrometer, X-ray Diffraction, etc. The spatial distribution of heavy metals varied significantly across the pipe section, and iron, manganese, lead, copper, and chromium were highest in concentration in the upper portion pipe-scales. However, the highest aluminum and zinc content was detected in the lower portion pipe-scales. Apart from some common types of hydrocarbons formed by microbial metabolites, there were also some microalgae metabolites and exogenous contaminants accumulated in pipe-scale, which also exhibited high diversity between different spatial locations. The spatial distributions of the physical and chemical properties of pipe-scale and contaminants were quite different in large-diameter pipes. The finding put forward higher requirements on the research method about drinking water distribution system chemical safety. And the scientific community need understand trend and dynamics of drinking water pipe systems better.

  20. Pipes's distribution by helicopter in Amazonian forest

    Energy Technology Data Exchange (ETDEWEB)

    Barbosa, Gilberto R.; Machado, Otto L.M.; Gomes, Antonio E. [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil)

    2009-12-19

    The innumerable logistical problems encountered during the implementation of the gas pipeline Urucu - Coari - Manaus, located in the Amazon forest, connecting the Base Operations Geologist Pedro de Moura in Urucu to the refinery Isaac Sabba - Reman, in the city of Manaus, contributed considerably for PETROBRAS to seek non conventional solutions in the construction and assembly of pipelines in our country. Among these solutions, there is the technique of distributing pipes through cargo helicopters. The need for the usage of this technique, innovative in Brazil, comes from the lack and/or insufficiency of land access from Solimoes River to the gas pipeline main route, and the large quantities of flooded areas and/or flood plain, and also the type of soil, that together with the high index of rainfall in the region, makes the soil fully inappropriate to the traffic of heavy equipment. (author)

  1. Application experience of gas-thermal aluminum coatings to protect the pipes for underground construction and repair of heat networks

    Science.gov (United States)

    Kolpakov, A. S.

    2013-11-01

    Questions of sacrificial protection for pipes of underground heat networks with aluminum against the external corrosion are considered. The description of pilot production of pipes with a plasma aluminum coating and the deposition of a sacrificial gas-plasma aluminum coating on weld joints of pipelines and the zone of their thermal influence during assemblage is presented. Examples of repairing the segments of distribution heat networks by the pipes with the tread protection are presented.

  2. Optical turbulence in a spinning pipe gas lens

    CSIR Research Space (South Africa)

    Mafusire, C

    2009-07-01

    Full Text Available The researchers have managed to do quantitative analysis of ‘controlled’ turbulence. The researchers could control the degree of turbulence by controlling the rotation speed and wall temperature of the spinning pipe gas lens. The researchers also...

  3. Wave aberrations in a spinning pipe gas lens

    CSIR Research Space (South Africa)

    Mafusire, C

    2009-06-01

    Full Text Available The graded index (GRIN-like) medium generated by a gas inside a heated pipe when it is rotated about its longitudinal axis has the ability to focus a laser beam. However, recent research has shown that the medium generated has a deleterious effect...

  4. Condensation driven water hammer studies for feedwater distribution pipe

    Energy Technology Data Exchange (ETDEWEB)

    Savolainen, S.; Katajala, S.; Elsing, B.; Nurkkala, P.; Hoikkanen, J. [Imatran Voima Oy, Vantaa (Finland); Pullinen, J. [IVO Power Engineering Ltd., Vantaa (Finland); Logvinov, S.A.; Trunov, N.B.; Sitnik, J.K. [EDO Gidropress (Russian Federation)

    1997-12-31

    Imatran Voima Oy, IVO, operates two VVER 440 reactors. Unit 1 has been operating since 1977 and unit 2 since 1981. First damages of the feed water distribution (FWD) pipes were observed in 1989. In closer examinations FWD-pipe T-connection turned out to suffer from severe erosion corrosion damages. Similar damages have been found also in other VVER 440 type NPPs. In 1994 the first new FWD-pipe was replaced and in 1996 extensive water hammer experiments were carried out together with EDO Gidropress in Podolsk. After the first phase of the experiments some fundamental changes were made to the construction of the FWD-pipe. The object of this paper is to give short insight to the design of the new FWD-pipe concentrating on water hammer experiments. (orig.).

  5. Condensation driven water hammer studies for feedwater distribution pipe

    International Nuclear Information System (INIS)

    Savolainen, S.; Katajala, S.; Elsing, B.; Nurkkala, P.; Hoikkanen, J.; Pullinen, J.; Logvinov, S.A.; Trunov, N.B.; Sitnik, J.K.

    1997-01-01

    Imatran Voima Oy, IVO, operates two VVER 440 reactors. Unit 1 has been operating since 1977 and unit 2 since 1981. First damages of the feed water distribution (FWD) pipes were observed in 1989. In closer examinations FWD-pipe T-connection turned out to suffer from severe erosion corrosion damages. Similar damages have been found also in other VVER 440 type NPPs. In 1994 the first new FWD-pipe was replaced and in 1996 extensive water hammer experiments were carried out together with EDO Gidropress in Podolsk. After the first phase of the experiments some fundamental changes were made to the construction of the FWD-pipe. The object of this paper is to give short insight to the design of the new FWD-pipe concentrating on water hammer experiments. (orig.)

  6. Residual stress distribution in extruded polypropylene pipes

    Czech Academy of Sciences Publication Activity Database

    Poduška, Jan; Kučera, J.; Hutař, Pavel; Ševčík, Martin; Křivánek, J.; Sadílek, J.; Náhlík, Luboš

    2014-01-01

    Roč. 2014, č. 40 (2014), s. 88-98 ISSN 0142-9418 R&D Projects: GA ČR(CZ) GAP108/12/1560 Institutional support: RVO:68081723 Keywords : polypropylene * extruded polymer pipe * residual stress * curved beam methodology * numerical simulations Subject RIV: JL - Materials Fatigue, Friction Mechanics Impact factor: 2.240, year: 2014 http://www.sciencedirect.com/science/article/pii/S0142941814001809

  7. Rejection of seamless pipe noise in magnetic flux leakage data obtained from gas pipeline inspection

    Science.gov (United States)

    Afzal, Muhammad; Udpa, Satish; Udpa, Lalita; Lord, William

    2000-05-01

    Natural gas is traditionally transmitted from production facilities to customer locations through a vast pipeline network. A major segment of this network employs seamless pipes. This is especially true for smaller diameter transmission and distribution lines. Manufacturing process associated with the production of seamless pipes contribute to a helical variation in the pipe along the axis. The deformation introduces an artifact in the data obtained from MFL inspection of these pipelines. This seamless pipe noise is usually correlated with signals generated by defects and other elements (joints, tees, etc.) in pipelines, and can therefore, mask their indications in MFL data. This warrants the need for methods to improve signal-to-noise ratio (SNR) in MFL data from seamless pipes. This paper presents a technique for detecting signals in MFL data from seamless pipes. The approach processes the data in various steps. First, a wavelet based denoising technique is applied to reduce the noise due to instrumentation and other sources. An adaptive filtering approach is then applied to reject seamless noise in the data. Since the inspection of pipelines typically generates vast amounts of data, it is imperative that the algorithm be computationally efficient. The processing method has to be robust in that it should be data independent. The approach described in this paper meet these criteria. Results from application of the approach to data from field tests are presented.

  8. Assessing the safety aspects for use of multilayer pipes in gas distribution of domestic installation; Avaliacao dos aspectos de seguranca para utilizacao de tubos multicamada em instalacoes de distribuicao de gas em residencias

    Energy Technology Data Exchange (ETDEWEB)

    Bratfisch, Carlos do Amaral Coutinho [Bratfisch - Engenharia em Gas, Sao Paulo, SP (Brazil); Emmeti, Sao Paulo, SP (Brazil); Collela, Ricardo [FGS Brasil Industria e Comercio Ltda., Cotia, SP (Brazil)

    2012-07-01

    The gas distribution networks average flow at the Brazilian market is low and the operating pressure is less than 2.0 kgf/cm{sup 2}. These values are lower if compared to other countries and due this, gas distribution companies, major builders and developers have started a movement to find alternatives to reduce their installation costs, and they have identified in other countries the multilayer system. Because of the great interest of the consumer market for this alternative, and since there is no standards in Brazil that could regulate it, a technical committee was established under the ABNT in order to prepare a standard draft meeting the local market particularities as well this technology requirements. Then it was initiated a quest looking for the knowledge of the 'state of the art' of this technology in various locations around the world, especially Europe, Asia and Oceania, which shows that, with few exceptions, the knowledge of this alternative is still on the beginning, and even in countries where this system is a pioneer some doubts exist with respect to their usage limit. The multilayer system materials were already used at hot and cold water networks for more than twelve years, but only after that it was made an adaptation for building installations of gas distribution networks. Due the need to search and establish safety criteria both with respect to the product as its installation shape, did the necessary motivation to perform a more detailed study of this new technology, meeting the needs of this market. The intention is to present to the consumer market a series of comparative data definitions and techniques to identify this as a modern, updated, economic, efficient and safe alternative option for gas distribution networks. (author)

  9. Experiments on vertical gas-liquid pipe flows using ultrafast X-ray tomography

    Energy Technology Data Exchange (ETDEWEB)

    Banowski, M.; Beyer, M.; Lucas, D.; Hoppe, D.; Barthel, F. [Helmholtz-Zentrum Dresden-Rossendorf (Germany). Inst. fuer Sicherheitsforschung

    2016-12-15

    For the qualification and validation of two-phase CFD-models for medium and large-scale industrial applications dedicated experiments providing data with high temporal and spatial resolution are required. Fluid dynamic parameter like gas volume fraction, bubble size distribution, velocity or turbulent kinetic energy should be measured locally. Considering the fact, that the used measurement techniques should not affect the flow characteristics, radiation based tomographic methods are the favourite candidate for such measurements. Here the recently developed ultrafast X-ray tomography, is applied to measure the local and temporal gas volume fraction distribution in a vertical pipe. To obtain the required frame rate a rotating X-ray source by a massless electron beam and a static detector ring are used. Experiments on a vertical pipe are well suited for development and validation of closure models for two-phase flows. While vertical pipe flows are axially symmetrically, the boundary conditions are well defined. The evolution of the flow along the pipe can be investigated as well. This report documents the experiments done for co-current upwards and downwards air-water and steam-water flows as well as for counter-current air-water flows. The details of the setup, measuring technique and data evaluation are given. The report also includes a discussion on selected results obtained and on uncertainties.

  10. Feed water distribution pipe replacement at Loviisa NPP

    Energy Technology Data Exchange (ETDEWEB)

    Savolainen, S.; Elsing, B. [Imatran Voima Loviisa NPP (Finland)

    1995-12-31

    Imatran Voima Oy operates two WWER-440 reactors. Unit 1 has been operating since 1977 and unit 2 since 1981. First damages of feed water distribution (FWD) pipe were observed in 1989. The FWD-pipe T-connection had suffered from severe erosion corrosion damages. Similar damages have been been found also in other WWER-440 type NPPs. In 1989 the nozzles of the steam generator YB11 were inspected. No signs of the damages or signs of erosion were detected. The first damaged nozzles were found in 1992 in steam generators of both units. In 1992 it was started studying different possibilities to either repair or replace the damaged FWD-pipes. Due to the difficult conditions for repairing the damaged nozzles it was decided to study different FWD-pipe constructions. In 1991 two new feedwater distributors had been implemented at Dukovany NPP designed by Vitckovice company. Additionally OKB Gidropress had presented their design for new collector. In spring 1994 all the six steam generators of Rovno NPP unit 1 were replaced with FWD-pipes designed by OKB Gidropress. After the implementation an experimental program with the new systems was carried out. Due to the successful experiments at Rovno NPP Unit 1 it was decided to implement `Gidropress solution` during 1994 refueling outage into the steam generator YB52 at Loviisa 2. The object of this paper is to discuss the new FWD-pipe and its effects on the plant safety during normal and accident conditions. (orig.).

  11. Multiple complementary gas distribution assemblies

    Science.gov (United States)

    Ng, Tuoh-Bin; Melnik, Yuriy; Pang, Lily L; Tuncel, Eda; Nguyen, Son T; Chen, Lu

    2016-04-05

    In one embodiment, an apparatus includes a first gas distribution assembly that includes a first gas passage for introducing a first process gas into a second gas passage that introduces the first process gas into a processing chamber and a second gas distribution assembly that includes a third gas passage for introducing a second process gas into a fourth gas passage that introduces the second process gas into the processing chamber. The first and second gas distribution assemblies are each adapted to be coupled to at least one chamber wall of the processing chamber. The first gas passage is shaped as a first ring positioned within the processing chamber above the second gas passage that is shaped as a second ring positioned within the processing chamber. The gas distribution assemblies may be designed to have complementary characteristic radial film growth rate profiles.

  12. Feasibility of Locating Leakages in Sewage Pressure Pipes Using the Distributed Temperature Sensing Technology.

    Science.gov (United States)

    Apperl, Benjamin; Pressl, Alexander; Schulz, Karsten

    2017-01-01

    The cost effective maintenance of underwater pressure pipes for sewage disposal in Austria requires the detection and localization of leakages. Extrusion of wastewater in lakes can heavily influence the water and bathing quality of surrounding waters. The Distributed Temperature Sensing (DTS) technology is a widely used technique for oil and gas pipeline leakage detection. While in pipeline leakage detection, fiber optic cables are installed permanently at the outside or within the protective sheathing of the pipe; this paper aims at testing the feasibility of detecting leakages with temporary introduced fiber optic cable inside the pipe. The detection and localization were tested in a laboratory experiment. The intrusion of water from leakages into the pipe, producing a local temperature drop, served as indicator for leakages. Measurements were taken under varying measurement conditions, including the number of leakages as well as the positioning of the fiber optic cable. Experiments showed that leakages could be detected accurately with the proposed methodology, when measuring resolution, temperature gradient and measurement time were properly selected. Despite the successful application of DTS for leakage detection in this lab environment, challenges in real system applications may arise from temperature gradients within the pipe system over longer distances and the placement of the cable into the real pipe system.

  13. A study of stratified gas-liquid pipe flow

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, George W.

    2005-07-01

    This work includes both theoretical modelling and experimental observations which are relevant to the design of gas condensate transport lines. Multicomponent hydrocarbon gas mixtures are transported in pipes over long distances and at various inclinations. Under certain circumstances, the heavier hydrocarbon components and/or water vapour condense to form one or more liquid phases. Near the desired capacity, the liquid condensate and water is efficiently transported in the form of a stratified flow with a droplet field. During operating conditions however, the flow rate may be reduced allowing liquid accumulation which can create serious operational problems due to large amounts of excess liquid being expelled into the receiving facilities during production ramp-up or even in steady production in severe cases. In particular, liquid tends to accumulate in upward inclined sections due to insufficient drag on the liquid from the gas. To optimize the transport of gas condensates, a pipe diameters should be carefully chosen to account for varying flow rates and pressure levels which are determined through the knowledge of the multiphase flow present. It is desirable to have a reliable numerical simulation tool to predict liquid accumulation for various flow rates, pipe diameters and pressure levels which is not presently accounted for by industrial flow codes. A critical feature of the simulation code would include the ability to predict the transition from small liquid accumulation at high flow rates to large liquid accumulation at low flow rates. A semi-intermittent flow regime of roll waves alternating with a partly backward flowing liquid film has been observed experimentally to occur for a range of gas flow rates. Most of the liquid is transported in the roll waves. The roll wave regime is not well understood and requires fundamental modelling and experimental research. The lack of reliable models for this regime leads to inaccurate prediction of the onset of

  14. ACOUSTIC DETECTING AND LOCATING GAS PIPE LINE INFRINGEMENT

    Energy Technology Data Exchange (ETDEWEB)

    John L. Loth; Gary J. Morris; George M. Palmer; Richard Guiler; Patrick Browning

    2004-12-01

    The extensive network of high-pressure natural gas transmission pipelines covering the United States provides an important infrastructure for our energy independence. Early detection of pipeline leaks and infringements by construction equipment, resulting in corrosion fractures, presents an important aspect of our national security policy. The National Energy Technology Laboratory Strategic Center for Natural Gas (SCVG) is and has been funding research on various applicable techniques. The WVU research team has focused on monitoring pipeline background acoustic signals generated and transmitted by gas flowing through the gas inside the pipeline. In case of a pipeline infringement, any mechanical impact on the pipe wall, or escape of high-pressure gas, generates acoustic signals traveling both up and down stream through the gas. Sudden changes in flow noise are detectable with a Portable Acoustic Monitoring Package (PAMP), developed under this contract. It incorporates a pressure compensating microphone and a signal- recording device. Direct access to the gas inside the line is obtained by mounting such a PAMP, with a 1/2 inch NPT connection, to a pipeline pressure port found near most shut-off valves. An FFT of the recorded signal subtracted by that of the background noise recorded one-second earlier appears to sufficiently isolate the infringement signal to allow source interpretation. Using cell phones for data downloading might allow a network of such 1000-psi rated PAMP's to acoustically monitor a pipeline system and be trained by neural network software to positively identify and locate any pipeline infringement.

  15. ACOUSTIC DETECTING AND LOCATING GAS PIPE LINE INFRINGEMENT

    Energy Technology Data Exchange (ETDEWEB)

    John L. Loth; Gary J. Morris; George M. Palmer; Richard Guiler; Patrick Browning

    2004-10-31

    The extensive network of high-pressure natural gas transmission pipelines covering the United States provides an important infrastructure for our energy independence. Early detection of pipeline leaks and infringements by construction equipment, resulting in corrosion fractures, presents an important aspect of our national security policy. The National Energy Technology Laboratory Strategic Center for Natural Gas (SCVG) is and has been funding research on various applicable techniques. The WVU research team has focused on monitoring pipeline background acoustic signals generated and transmitted by gas flowing through the gas inside the pipeline. In case of a pipeline infringement, any mechanical impact on the pipe wall, or escape of high-pressure gas, generates acoustic signals traveling both up and down stream through the gas. Sudden changes in flow noise are detectable with a Portable Acoustic Monitoring Package (PAMP), developed under this contract. It incorporates a pressure compensating microphone and a signal- recording device. Direct access to the gas inside the line is obtained by mounting such a PAMP, with a 1/2 inch NPT connection, to a pipeline pressure port found near most shut-off valves. An FFT of the recorded signal subtracted by that of the background noise recorded one-second earlier appears to sufficiently isolate the infringement signal to allow source interpretation. Using cell phones for data downloading might allow a network of such 1000-psi rated PAMP's to acoustically monitor a pipeline system and be trained by neural network software to positively identify and locate any pipeline infringement.

  16. Gas distribution equipment in hydrogen service - Phase II

    Science.gov (United States)

    Jasionowski, W. J.; Huang, H. D.

    1980-01-01

    The hydrogen permeability of three different types of commercially available natural gas polyethylene pipes was determined. Ring tensile tests were conducted on permeability-exposed and as-received samples. Hydrogen-methane leakage experiments were also performed. The results show no selective leakage of hydrogen via Poiseuille, turbulent, or orifice flow (through leaks) on the distribution of blends of hydrogen and methane. The data collected show that the polyethylene pipe is 4 to 6 times more permeable to hydrogen than to methane.

  17. Feasibility of Locating Leakages in Sewage Pressure Pipes Using the Distributed Temperature Sensing Technology

    OpenAIRE

    Apperl, Benjamin; Pressl, Alexander; Schulz, Karsten

    2017-01-01

    The cost effective maintenance of underwater pressure pipes for sewage disposal in Austria requires the detection and localization of leakages. Extrusion of wastewater in lakes can heavily influence the water and bathing quality of surrounding waters. The Distributed Temperature Sensing (DTS) technology is a widely used technique for oil and gas pipeline leakage detection. While in pipeline leakage detection, fiber optic cables are installed permanently at the outside or within the protective...

  18. 46 CFR 56.50-103 - Fixed oxygen-acetylene distribution piping.

    Science.gov (United States)

    2010-10-01

    ... distribution of oxygen and acetylene carried in cylinders as vessels stores. (b) The distribution piping shall... outlet stations. (c) Acetylene distribution piping and pipe fittings must be seamless steel. Copper... openings to spaces or tanks. (j) Outlet stations are to be provided with suitable protective devices which...

  19. Film behaviour of vertical gas-liquid flow in a large diameter pipe

    OpenAIRE

    Zangana, Mohammed Haseeb Sedeeq

    2011-01-01

    Gas-liquid flow commonly occurs in oil and gas production and processing system. Large diameter vertical pipes can reduce pressure drops and so minimize operating costs. However, there is a need for research on two-phase flow in large diameter pipes to provide confidence to designers of equipments such as deep water risers. In this study a number of experimental campaigns were carried out to measure pressure drop, liquid film thickness and wall shear in 127mm vertical pipe. Total pressur...

  20. Characterisation of a spinning pipe gas lens using a Shack–Hartmann wavefront sensor

    CSIR Research Space (South Africa)

    Mafusire, C

    2007-01-01

    Full Text Available A heated horizontal spinning pipe causes gases inside it to assume dynamics resulting in a graded index lens – a spinning pipe gas lens (SPGL). A CFD model is presented which shows that gas exchanges of the SPGL with the surroundings resulting in a...

  1. 76 FR 40717 - Transcontinental Gas Pipe Line Company, LLC; Notice of Intent To Prepare an Environmental...

    Science.gov (United States)

    2011-07-11

    .... Date and time Location Monday, July 18, 2011, 6 p.m. EDT. Hughesville Volunteer Fire Company, Social... Gas Pipe Line Company, LLC; Notice of Intent To Prepare an Environmental Assessment for the Planned... (Project) involving construction and operation of facilities by Transcontinental Gas Pipe Line Company, LLC...

  2. Excellent impact performance of PVC pipeline materials in gas distribution networks after many years of service (CD-rom)

    NARCIS (Netherlands)

    Visser, Roy; Hermkens, R.M.J.; Wolters, Mannes; Weller, J.; Warnet, Laurent; Beckervordersandforth, C.; Verberg, G.H.B.; Kramer, M.

    2008-01-01

    It has been about fifty years ago since the first unplasticized poly(vinyl chloride) (uPVC) pipes were installed for use in gas distribution purposes. Currently, about 22,500 km of uPVC is still in use in the Dutch gas distribution network. The pipes were originally designed for a lifetime of 50

  3. Productivity improvements in gas distribution

    International Nuclear Information System (INIS)

    Young, M.R.

    1997-01-01

    In 1993, the Hilmer Report resulted in the introduction of the National Competition Policy which, in the case of the gas industry, aims to promote gas-on-gas competition where to date it has been excluded. In response, and to prepare for wide gas industry reform, Gas and Fuel formed three fundamentally different core businesses on 1 July 1996 - Energy Retail, Network, and Contestable Services. In one productivity improvement initiative which is believed to be unique, Gas and Fuel appointed three companies as strategic alliance partners for distribution system maintenance. Gas and Fuel can now concentrate on its core role as asset manager which owns and operates the distribution system while procuring all services from what will become non-regulated businesses. This Paper details this initiative and the benefits which have resulted from overall changes and improvements, and outlines the challenges facing Gas and Fuel in the future. (au)

  4. 46 CFR 61.15-10 - Liquefied-petroleum-gas piping for heating and cooking.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Liquefied-petroleum-gas piping for heating and cooking. 61.15-10 Section 61.15-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE... piping for heating and cooking. (a) Leak tests as described in paragraph (b) of this section shall be...

  5. Evaluation of residual stress distribution in austenitic stainless steel pipe butt-welded joint

    International Nuclear Information System (INIS)

    Maekawa, Akira; Noda, Michiyasu; Takahashi, Shigeru; Oumaya, Toru; Serizawa, Hisashi; Murakawa, Hidekazu

    2009-01-01

    This paper reports measured and estimated results of residual stress distributions of butt-welded austenitic stainless steel pipe in order to improve estimation accuracy of welding residual stress. Neutron diffraction and strain gauge method were employed for the measurement of the welding residual stress and its detailed distributions on inner and outer surface of the pipe as well as the distributions within the pipe wall were obtained. Finite element method was employed for the estimation. Transient and residual stresses in 3D butt-welded joint model were computed by employing Iterative Substructure Method and also commercial FEM code ABAQUS for a reference. The measured and estimated distributions presented typical characteristic of straight butt-welded pipe which had decreasing trend along the axial direction and bending type distributions through wall of the pipe. Both results were compared and the accuracy of measurement and estimation was discussed. (author)

  6. Residual Stress Distribution in Carbon Steel Pipe Welded Joint Measured by Neutron Diffraction

    OpenAIRE

    Makoto, HAYASHI; Masayuki, ISHIWATA; Yukio, MORII; Nobuaki, MINAKAWA; ROOT, John H.; Mechanical Engineering Research Laboratory, Hitachi, Ltd.,; Nuclear Engineering Division, Hitachi Ltd.,; Tokai Establishment, Japan Atomic Energy Research Institute; Tokai Establishment, Japan Atomic Energy Research Institute; National Research Council of Canada

    2000-01-01

    In order to estimate crack growth behavior of fatigue and stress corrosion cracking in pipes, the residual stress distribution near the pipe weld region has to be measured through the wall thickness.Since the penetration depth of neutron is deep enough to pass through the thick pipe wall, the neutron diffraction technique for the residual stress measurement is effective for this purpose.At the first step the residual stress distribution near the weld region in a butt-welded carbon steel pipe ...

  7. Severe slugging in gas-liquid two-phase pipe flow

    NARCIS (Netherlands)

    Malekzadeh, R.

    2012-01-01

    transportation facilities. In an offshore oil and gas production facility, pipeline-riser systems are required to transport two-phase hydrocarbons from subsurface oil and gas wells to a central production platform. Severe slugs reaching several thousands pipe diameters may occur when transporting

  8. Market study of pipe gas for the Bahia State, Brazil

    International Nuclear Information System (INIS)

    1992-09-01

    The energy market that will be conquered by the natural gas in Bahia State is identified, allowing measure the potentiality of gas industry and the gas supply, that the State will plead to the Federal Government. (C.G.C.)

  9. The assessment of water loss from a damaged distribution pipe using the FEFLOW software

    OpenAIRE

    Iwanek Małgorzata; Suchorab Paweł

    2017-01-01

    Common reasons of real water loss in distribution systems are leakages caused by the failures or pipe breakages. Depending on the intensity of leakage from a damaged buried pipe, water can flow to the soil surface just after the failure occurs, much later or never at all. The localization of the place where the pipe breakage occurs is relatively easy when water outflow occurs on the soil surface. The volume of lost water strongly depends on the time it takes to localize the place of a pipe br...

  10. An analysis of the temperature distribution in the pipe bending using high frequency induction heating

    International Nuclear Information System (INIS)

    Fukue, Hisayoshi; Mochizuki, Yoji; Nakamura, Harushige; Kobo, Hiroshi; Nitta, Tetsuo; Kawakami, Kiyoshi

    1986-01-01

    A pipe bending apparatus has recently been developed by applying high frequency induction heating. However, the smaller the radius of pipe bending, the greater becomes the reduction in wall thickness and the ovality of the pipe form. This makes it impossible to manufacture pipe bending which will meet the nuclear pipe design code. In order to solve this problem it is crucial to obtain a temperature distributions in a pipe which is moving. It is calculated by giving the following boundary conditions : distribution of the heat generation rate, and that of heat transfer of cooling water. In the process of analyzing these distributions, the following results were obtained. (1) The distribution of the heat generation rate is determined by the sink of energy flux of Poynting vectors. The coil efficiency thus calculated was sixty percent. This figure accords with the test data. (2) The distribution of heat transfer coefficient of cooling water is mainly determined by the rate of liquid film heat transfer, but departure from nucleate boiling and dryout has to be taken into consideration. (3) TRUMP CODE is modified so that the temperature distribution in moving pipes can be calculated by taking the boundary conditions into account. The calculated results were in accordance with the test data. (author)

  11. A LOW-COST GPR GAS PIPE & LEAK DETECTOR

    Energy Technology Data Exchange (ETDEWEB)

    David Cist; Alan Schutz

    2005-03-30

    A light-weight, easy to use ground penetrating radar (GPR) system for tracking metal/non-metal pipes has been developed. A pre-production prototype instrument has been developed whose production cost and ease of use should fit important market niches. It is a portable tool which is swept back and forth like a metal detector and which indicates when it goes over a target (metal, plastic, concrete, etc.) and how deep it is. The innovation of real time target detection frees the user from having to interpret geophysical data and instead presents targets as dots on the screen. Target depth is also interpreted automatically, relieving the user of having to do migration analysis. In this way the user can simply walk around looking for targets and, by ''connecting the dots'' on the GPS screen, locate and follow pipes in real time. This is the first tool known to locate metal and non-metal pipes in real time and map their location. This prototype design is similar to a metal detector one might use at the beach since it involves sliding a lightweight antenna back and forth over the ground surface. The antenna is affixed to the end of an extension that is either clipped to or held by the user. This allows him to walk around in any direction, either looking for or following pipes with the antenna location being constantly recorded by the positioning system. Once a target appears on the screen, the user can locate by swinging the unit to align the cursor over the dot. Leak detection was also a central part of this project, and although much effort was invested into its development, conclusive results are not available at the time of the writing of this document. Details of the efforts that were made as a part of this cooperative agreement are presented.

  12. Modeling of ITER related vacuum gas pumping distribution systems

    Energy Technology Data Exchange (ETDEWEB)

    Misdanitis, Serafeim [University of Thessaly, Department of Mechanical Engineering, Pedion Areos, 38334 Volos (Greece); Association EURATOM - Hellenic Republic (Greece); Valougeorgis, Dimitris, E-mail: diva@mie.uth.gr [University of Thessaly, Department of Mechanical Engineering, Pedion Areos, 38334 Volos (Greece); Association EURATOM - Hellenic Republic (Greece)

    2013-10-15

    Highlights: • An algorithm to simulate vacuum gas flows through pipe networks consisting of long channels and channels of moderate length has been developed. • Analysis and results are based on kinetic theory as described by the BGK kinetic model equation. • The algorithm is capable of computing the mass flow rates (or the conductance) through the pipes and the pressure at the nodes of the network. • Since a kinetic approach is implemented, the algorithm is valid in the whole range of the Knudsen number. • The developed algorithm will be useful for simulating the vacuum distribution systems of ITER and future fusion reactors. -- Abstract: A novel algorithm recently developed to solve steady-state isothermal vacuum gas dynamics flows through pipe networks consisting of long tubes is extended to include, in addition to long channels, channels of moderate length 10 < L/D < 50. This is achieved by implementing the so-called end effect treatment/correction. Analysis and results are based on kinetic theory as described by the Boltzmann equation or associated reliable kinetic model equations. For a pipe network of known geometry the algorithm is capable of computing the mass flow rates (or the conductance) through the pipes as well as the pressure heads at the nodes of the network. The feasibility of the approach is demonstrated by simulating two ITER related vacuum distribution systems, one in the viscous regime and a second one in a wide range of Knudsen numbers. Since a kinetic approach is implemented, the algorithm is valid and the results are accurate in the whole range of the Knudsen number, while the involved computational effort remains small.

  13. Bacterial community radial-spatial distribution in biofilms along pipe wall in chlorinated drinking water distribution system of East China.

    Science.gov (United States)

    Liu, Jingqing; Ren, Hongxing; Ye, Xianbei; Wang, Wei; Liu, Yan; Lou, Liping; Cheng, Dongqing; He, Xiaofang; Zhou, Xiaoyan; Qiu, Shangde; Fu, Liusong; Hu, Baolan

    2017-01-01

    Biofilms in the pipe wall may lead to water quality deterioration and biological instability in drinking water distribution systems (DWDSs). In this study, bacterial community radial-spatial distribution in biofilms along the pipe wall in a chlorinated DWDS of East China was investigated. Three pipes of large diameter (300, 600, and 600 mm) were sampled in this DWDS, including a ductile cast iron pipe (DCIP) with pipe age of 11 years and two gray cast iron pipes (GCIP) with pipe ages of 17 and 19 years, and biofilms in the upper, middle, and lower parts of each pipe wall were collected. Real-time quantitative polymerase chain reaction (qPCR) and culture-based method were used to quantify bacteria. 454 pyrosequencing was used for bacterial community analysis. The results showed that the biofilm density and total solid (TS) and volatile solid (VS) contents increased gradually from the top to the bottom along the pipe wall. Microorganisms were concentrated in the upper and lower parts of the pipe wall, together accounting for more than 80 % of the total biomass in the biofilms. The bacterial communities in biofilms were significantly different in different areas of the pipe wall and had no strong interaction. Compared with the upper and lower parts of the pipe wall, the bacterial community in the middle of the pipe wall was distributed evenly and had the highest diversity. The 16S rRNA genes of various possible pathogens, including Escherichia coli, Staphylococcus epidermidis, Pseudomonas aeruginosa, and Salmonella enterica, were detected in the biofilms, and the abundances of these possible pathogens were highest in the middle of the pipe wall among three areas. The detachment of the biofilms is the main reason for the deterioration of the water quality in DWDSs. The results of this study suggest that the biofilms in the middle of the pipe wall have highly potential risk for drinking water safety, which provides new ideas for the study of the microbial ecology in

  14. Formation of Sclerotic Hydrate Deposits in a Pipe for Extraction of a Gas from a Dome Separator

    Science.gov (United States)

    Urazov, R. R.; Chiglinstev, I. A.; Nasyrov, A. A.

    2017-09-01

    The theory of formation of hydrate deposits on the walls of a pipe for extraction of a gas from a dome separator designed for the accident-related collection of hydrocarbons on the ocean floor is considered. A mathematical model has been constructed for definition of a steady movement of a gas in such a pipe with gas-hydrate deposition under the conditions of changes in the velocity, temperature, pressure, and moisture content of the gas flow.

  15. The Effect of Gas Kinetics on the Gas-Lift Efficiency for Viscous Oil in Vertical Pipe Flow

    OpenAIRE

    Steinbakk, Carina Hoddø

    2015-01-01

    For heavy oil, artificial lift can be applied to increase and stabilise production flow. How the gas kinetics, i.e. the lift-gas composition will influence this increase is the subject of this thesis and will be described in relation to multiphase flow, pressure drop and pressure-temperature-volume (PVT) -theory. A vertical pipe flow was studied, simulating the pressure drop coupled with the accompanying multiphase flow and PVT-information. The simulations were run in MATLAB, supported by...

  16. 77 FR 55208 - Transcontinental Gas Pipe Line Company, LLC; Notice of Intent To Prepare an Environmental...

    Science.gov (United States)

    2012-09-07

    .... You must wait until the Commission receives a formal application for the Project. Additional...] Transcontinental Gas Pipe Line Company, LLC; Notice of Intent To Prepare an Environmental Assessment for the Planned Virginia Southside Expansion Project; Request for Comments on Environmental Issues and Notice of...

  17. 75 FR 42738 - Transcontinental Gas Pipe Line Company, LLC; Notice of Intent To Prepare an Environmental...

    Science.gov (United States)

    2010-07-22

    ... must wait until a formal application for the project is filed with the Commission. Additional...] Transcontinental Gas Pipe Line Company, LLC; Notice of Intent To Prepare an Environmental Assessment for the Planned Mid-Atlantic Connector Expansion Project, Request for Comments on Environmental Issues, and Notice...

  18. 75 FR 51455 - Transcontinental Gas Pipe Line Company, LLC; Notice of Intent To Prepare an Environmental...

    Science.gov (United States)

    2010-08-20

    ... must wait until a formal application for the project is filed with the Commission. Additional...] Transcontinental Gas Pipe Line Company, LLC; Notice of Intent To Prepare an Environmental Assessment for the Planned Mid-South Expansion Project and Request for Comments on Environmental Issues August 13, 2010. The...

  19. Study on heat pipe assisted thermoelectric power generation system from exhaust gas

    Science.gov (United States)

    Chi, Ri-Guang; Park, Jong-Chan; Rhi, Seok-Ho; Lee, Kye-Bock

    2017-11-01

    Currently, most fuel consumed by vehicles is released to the environment as thermal energy through the exhaust pipe. Environmentally friendly vehicle technology needs new methods to increase the recycling efficiency of waste exhaust thermal energy. The present study investigated how to improve the maximum power output of a TEG (Thermoelectric generator) system assisted with a heat pipe. Conventionally, the driving energy efficiency of an internal combustion engine is approximately less than 35%. TEG with Seebeck elements is a new idea for recycling waste exhaust heat energy. The TEG system can efficiently utilize low temperature waste heat, such as industrial waste heat and solar energy. In addition, the heat pipe can transfer heat from the automobile's exhaust gas to a TEG. To improve the efficiency of the thermal power generation system with a heat pipe, effects of various parameters, such as inclination angle, charged amount of the heat pipe, condenser temperature, and size of the TEM (thermoelectric element), were investigated. Experimental studies, CFD simulation, and the theoretical approach to thermoelectric modules were carried out, and the TEG system with heat pipe (15-20% charged, 20°-30° inclined configuration) showed the best performance.

  20. An acoustic technique for tracing plastic pipe

    Energy Technology Data Exchange (ETDEWEB)

    Huebler, J.E.; Campbell, B.K. (Inst. of Gas Technology, Chicago, IL (United States)); Ching, G.K. (Southern California Gas Co., Los Angeles, CA (United States). Research Dept.)

    1993-08-01

    Many operation and maintenance activities performed by a gas distribution company require precise knowledge of the location of the gas main and/or service. These activities range from pipe location for the repair of a leak to the marking of pipe location as part of a one call system. Records provide one method of knowing the location of piping; however, these records are not always sufficiently accurate for field work. Thus, techniques for pipe location have always been an important need of the industry, and electromagnetic pipe locators have filled this need for years. Electromagnetic pipe locators, however, cannot find plastic pipe unless a tracer wire is buried next to or above the pipe. With the increased use of plastic pipe, a new technique for finding buried pipe is required. A successful acoustic plastic pipe locator could eliminate the use of tracer wire in new polyethylene pipe installations, thereby reducing pipe installation costs. Under sponsorship of the Southern California Gas Company, the Institute of Gas Technology (IGT) successfully demonstrated the proof-of-concept of an active acoustic plastic pipe location technique and is developing the technique into a practical field instrument.

  1. Experiments in stratified gas-liquid pipe flow

    NARCIS (Netherlands)

    Birvalski, M.

    2015-01-01

    The growing demand for energy in the future will necessitate the production of natural gas from fields which are located farther offshore, in deep water and in very cold environments. This will confront us with difficulties in ensuring continuous production of the fluids (natural gas, condensate and

  2. Phenomena and Detection of Gas Accumulation in Piping Systems

    International Nuclear Information System (INIS)

    Lee, D. Y.; Jeon, S. S.; Hong, S. J.; Song, Y. J.

    2011-01-01

    U.S. Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 2008-01 which provides recommendation and guidance to nuclear power plants for managing gas intrusion and accumulation in safety systems such as Emergency Core Cooling (ECC), Decay Heat Removal (DHR) and Containment Spray (CS) systems. Following the GL2008-01, Nuclear Energy Institute (NEI) reported NEI 09-10 that gives industry guidance for effective prevention and management of system gas accumulation. All of U.S. utilities responded to the GL2008-01 with evaluation results for gas accumulation in safety systems mentioned above. This paper summarizes key phenomena to be evaluated against gas accumulation in safety systems and detection methods for gas accumulation in subjected systems

  3. 24 CFR 3280.705 - Gas piping systems.

    Science.gov (United States)

    2010-04-01

    ... following information using letters no smaller than 1/4 inch high: Do Not Use Tools To Separate the “Quick... liquefied petroleum gas, and shall be applied to the male threads only. (h) Concealed tubing. Tubing shall...

  4. Development of a computer program for the simulation of gas permeation through the walls of flexible pipes

    Energy Technology Data Exchange (ETDEWEB)

    Mello, Paulo Eduardo Batista de [Dept. de Engenharia Mecanica. Centro Universitario da FEI, Sao Bernardo do Campo, SP (Brazil)], e-mail: pmello@fei.edu.br; Barbosa Neto, Teofilo Ferreira; Godinho, Carlos Alberto [Prysmian, Vila Velha, ES (Brazil)], e-mails: teofilo.barbosa@prysmian.com, carlos.godinho@prysmian.com; Yanagihara, Jurandir Itizo [Dept. de Engenharia Mecanica. Escola Politecnica. Universidade de Sao Paulo, SP (Brazil)], e-mail: jiy@usp.br

    2010-07-01

    The design of flexible pipes, used in the petroleum industry, must consider a great number of failure modes. Among them, the problems due to chemical corrosion in the metallic layers that constitute the armors are of the foremost importance. These armors are protected by polymer sheaths, internally and externally, forming one annular space. The gas that is transported by the flexible pipe permeates continuously through the polymer sheaths, increasing the pressure in the annular space. This work presents the transient numerical method and results obtained with a computer code capable of simulating the process of permeation of gases through polymer walls considering the radial and axial directions. The program is capable of predicting the chemical composition in the annulus, at given design conditions of the flexible pipe. Temperature distribution in the radial direction is also calculated in order to consider the variation of mass diffusion coefficients with temperature. The venting process of the annular space, that is used for this kind of equipment, is considered in the simulations. (author)

  5. Transition of Gas-Liquid Stratified Flow in Oil Transport Pipes

    Directory of Open Access Journals (Sweden)

    D. Lakehal

    2011-12-01

    Full Text Available Large-Scale Simulation results of the transition of a gas-liquid stratified flow to slug flow regime in circular 3D oil transport pipes under turbulent flow conditions expressed. Free surface flow in the pipe is treated using the Level Set method. Turbulence is approached via the LES and VLES methodologies extended to interfacial two-phase flows. It is shown that only with the Level Set method the flow transition can be accurately predicted, better than with the two-fluid phase-average model. The transition from stratified to slug flow is found to be subsequent to the merging of the secondary wave modes created by the action of gas shear (short waves with the first wave mode (high amplitude long wave. The model is capable of predicting global flow features like the onset of slugging and slug speed. In the second test case, the model predicts different kinds of slugs, the so-called operating slugs formed upstream that fill entirely the pipe with water slugs of length scales of the order of 2-4 D, and lower size (1-1.5 D disturbance slugs, featuring lower hold-up (0.8-0.9. The model predicts well the frequency of slugs. The simulations revealed important parameter effects on the results, such as two-dimensionality, pipe length, and water holdup.

  6. Effectiveness of the Vertical Gas Ventilation Pipes for Promoting Waste Stabilization in Post-Closure Phase

    Directory of Open Access Journals (Sweden)

    Yasumasa Tojo

    2015-06-01

    Full Text Available To make inside of the municipal solid waste (MSW landfill aerobic as much as possible is thought to be preferable for promoting waste stabilization, reducing pollutant's load in leachate, minimizing greenhouse gas emission and shortening post-closure-care period. In Japan, installation of semi-aerobic landfill structure has widely spread in order to promote waste stabilization in MSW landfill from 1980s. In semi-aerobic landfill structure, outlet of main leachate collection pipe is opened to atmosphere. Heat generated by aerobic degradation of waste causes natural convection and natural aeration arises from the outlet of leachate collection pipe to the gas vents. It is so-called stack effect. This air flow is thought to be effective for purifying leachate flowing through drainage layer and leachate collection pipes. And it is also thought to be contributing to expanding aerobic region in waste layer in landfill. Recently, measures attempting the promotion of waste stabilization are taken at several landfills at where stabilization of waste delays, in which many vertical gas vents are newly installed and close structure to semi-aerobic landfill is created. However, in many cases, these gas vents are not connected to leachate collection pipes. Many vertical gas vents are just installed without scientific proof regarding whether they can contribute for waste stabilization. In this study, how such installation of gas vents is effective for waste stabilization and aerobization of waste layer was discussed by numerical analysis. In numerical analysis, heat transfer, gas movement by pressure, gas diffusion, biological degradation of organic matter, and heat generation by biodegradation were taken into account. Simulations were carried out by using the general purpose simulator of finite element method. Three types of landfill structure were assumed. As the results, the following information were obtained. In dig-down type landfill, installation of gas

  7. Computational fluid dynamics model of the spinning pipe gas lens

    CSIR Research Space (South Africa)

    Mafusire, C

    2010-08-01

    Full Text Available has a vertical symmetry due to gravity but becomes rotationally symmetric with a higher value of density at the core as rotation speed increases. The longitudinal density distribution is shown to be parabolic towards the ends but is fairly uniform...

  8. Modelling of stratified gas-liquid two-phase flow in horizontal circular pipes

    International Nuclear Information System (INIS)

    Sampaio, P.A.B. de; Faccini, J.L.H.; Su, J.

    2006-01-01

    This paper reports numerical and experimental investigation of stratified gas-liquid two-phase flow in horizontal circular pipes. The Reynolds average Navier-Stokes equations (RANS) with κ ω model development stratified gas-liquid two-phase flow are solved by using the finite element methods. A smooth interface surface is assumed without considered the effects of the interfacial waves. The continuity of the shear stress across the interface is enforced with the continuity of the velocity being automatically satisfied by the variational formulation. For it is given position and interface and longitudinal pressure gradient, an inner iteration loop runs to solve nonlinear equations the Newton-Raphson scheme is used to solve the transcendental equations by an outer iteration to determinate the interface position in a 5.2 mm ID circular pipe was measured experimentally by the ultrasonic ultra pulse-echo technique. The numeral were also compared with results in 21 mm ID circular pipe report by Masala (2004). The good agreement between the numerical and experimental results indicates that κ ω model can be applied for the numerical simulation of stratified gas-liquid two phase flow. (author)

  9. Model for radial gas fraction profiles in vertical pipe flow

    International Nuclear Information System (INIS)

    Lucas, D.; Krepper, E.; Prasser, H.M.

    2001-01-01

    A one-dimensional model is presented, which predicts the radial volume fraction profiles from a given bubble size distribution. It bases on the assumption of an equilibrium of the forces acting on a bubble perpendicularly to the flow path (non drag forces). For the prediction of the flow pattern this model could be used within an procedure together with appropriate models for local bubble coalescence and break-up. (orig.)

  10. The assessment of water loss from a damaged distribution pipe using the FEFLOW software

    Directory of Open Access Journals (Sweden)

    Iwanek Małgorzata

    2017-01-01

    Full Text Available Common reasons of real water loss in distribution systems are leakages caused by the failures or pipe breakages. Depending on the intensity of leakage from a damaged buried pipe, water can flow to the soil surface just after the failure occurs, much later or never at all. The localization of the place where the pipe breakage occurs is relatively easy when water outflow occurs on the soil surface. The volume of lost water strongly depends on the time it takes to localize the place of a pipe breakage. The aim of this paper was to predict the volume of water lost between the moment of a failure occurring and the moment of water outflow on the soil surface, during a prospective failure in a distribution system. The basis of the analysis was a numerical simulation of a water pipe failure using the FEFLOW v. 5.3 software (Finite Element subsurface FLOW systems for a real middle-sized distribution system. Simulations were conducted for variants depending on pipes’ diameter (80÷200 mm for minimal and maximal hydraulic pressure head in the system (20.14 and 60.41 m H2O, respectively. FEFLOW software application enabled to select places in the water system where possible failures would be difficult to detect.

  11. New gas in old pipes: opening the UK residential gas market to competition

    International Nuclear Information System (INIS)

    Waddams Price, C.; Bennett, M.

    1999-01-01

    The United Kingdom is introducing competition to its residential gas and electricity markets, the first such experiment on a national level. This paper analyses the behaviour of suppliers and consumers in the first market to be opened, based on suppliers' posted prices, two questionnaires to consumers and information from the incumbent. The results confirm predictions about the unwinding of cross-subsidies; a surprisingly small proportion of consumers are switching to other suppliers, and they are not evenly distributed across consumer groups, raising important policy questions about the future of regulation in such markets

  12. Project Scheduling Based on Risk of Gas Transmission Pipe

    Science.gov (United States)

    Silvianita; Nurbaity, A.; Mulyadi, Y.; Suntoyo; Chamelia, D. M.

    2018-03-01

    The planning of a project has a time limit on which must be completed before or right at a predetermined time. Thus, in a project planning, it is necessary to have scheduling management that is useful for completing a project to achieve maximum results by considering the constraints that will exists. Scheduling management is undertaken to deal with uncertainties and negative impacts of time and cost in project completion. This paper explains about scheduling management in gas transmission pipeline project Gresik-Semarang to find out which scheduling plan is most effectively used in accordance with its risk value. Scheduling management in this paper is assissted by Microsoft Project software to find the critical path of existing project scheduling planning data. Critical path is the longest scheduling path with the fastest completion time. The result is found a critical path on project scheduling with completion time is 152 days. Furthermore, the calculation of risk is done by using House of Risk (HOR) method and it is found that the critical path has a share of 40.98 percent of all causes of the occurence of risk events that will be experienced.

  13. Optimization of distribution piping network in district cooling system using genetic algorithm with local search

    International Nuclear Information System (INIS)

    Chan, Apple L.S.; Hanby, Vic I.; Chow, T.T.

    2007-01-01

    A district cooling system is a sustainable means of distribution of cooling energy through mass production. A cooling medium like chilled water is generated at a central refrigeration plant and supplied to serve a group of consumer buildings through a piping network. Because of the substantial capital investment involved, an optimal design of the distribution piping configuration is one of the crucial factors for successful implementation of the district cooling scheme. In the present study, genetic algorithm (GA) incorporated with local search techniques was developed to find the optimal/near optimal configuration of the piping network in a hypothetical site. The effect of local search, mutation rate and frequency of local search on the performance of the GA in terms of both solution quality and computation time were investigated and presented in this paper

  14. Security resolution minute for natural gas distribution pipeline; Minuta de resolucao de seguranca na distribuicao do gas natural

    Energy Technology Data Exchange (ETDEWEB)

    Teles, Marcus de Barros [ARCE - Agencia Reguladora de Servicos Publicos Delegados do Estado do Ceara, Fortaleza, CE (Brazil)

    2003-07-01

    In the current scenery of natural gas distribution regulation, there is no specific resolution about security. The security is boarded in few concession contracts of some private gas companies, but not as principal theme. The security resolution minute presented in this paper aim break the direct and indirect causes of accidents, eliminating their potential. In this new point of view, the quality of services is the principal cause to guarantee the security of natural gas distribution systems. The methodology used to develop the minute was based on the research of Brazilian and American resolutions of state regulation agencies, concession contracts of private distribution gas companies, American code of federal regulation, ASME code for pressure piping B31.8 - 1999 edition and the NBR 12712 standard. The result of the research was the elaboration of an specific minute resolution of security that can be used as reference in the fiscalization of the natural gas distribution piping companies activities. This minute, can be an important instrument to avoid accidents and incidents, eliminating prejudices to the people, to properties, to environment and to the image of natural gas distribution companies and regulation agencies. (author)

  15. Numerical modelling of isothermal gas-liquid two-phase bubbly flow in vertical pipes

    International Nuclear Information System (INIS)

    Yamoah, S.

    2014-07-01

    lubrication and turbulent dispersion force models. Overall, the comparison has shown that the MUSIG model yielded satisfactory agreement with the experimental data. The transition from wall peak to core peak gas volume fraction profiles has been successfully captured and encouraging results clearly exemplified the capability of the model in capturing the dynamical changes of bubble size due to coalescence and breakup processes. The observed agreement with the gas volume fraction profiles indicates a level of confidence in the interfacial force models (especially the lift coefficient model) used, while on the other hand, the agreement seen on the interfacial area concentration indicates that the birth and death processes modelled are reasonably adequate to describe the bubble dynamics. Nevertheless, noticeable discrepancies in simulating bimodal bubble size distributions were found revealing the plausible imperfection of existing coalescence and breakup kernels. Thirdly, the performance of the interfacial area transport equation has been assessed by implementing some typical constitutive models for bubble coalescence and breakup taken from literature. The interfacial area transport equation has been successfully implemented into the CFD code and the constitutive model formulations from Hibiki and Ishii (2000a), Wu et al. (1998) with coefficients from Ishii and Kim (2001) and Wang (2010) have been implemented and validated. The combined effects of lift and wall lubrication force have been investigated. Both models of the lATE source and sink terms were able to reasonably capture the experimental data especially the gas volume fraction profiles. More experimental and theoretical work needs to be done in this field to increase the prediction capability of the simulation tools regarding the distribution of the phases along the pipe radius. (au)

  16. The Challenge of Providing Safe Water with an Intermittently Supplied Piped Water Distribution System

    Science.gov (United States)

    Kumpel, E.; Nelson, K. L.

    2012-12-01

    An increasing number of urban residents in low- and middle-income countries have access to piped water; however, this water is often not available continuously. 84% of reporting utilities in low-income countries provide piped water for fewer than 24 hours per day (van den Berg and Danilenko, 2010), while no major city in India has continuous piped water supply. Intermittent water supply leaves pipes vulnerable to contamination and forces households to store water or rely on alternative unsafe sources, posing a health threat to consumers. In these systems, pipes are empty for long periods of time and experience low or negative pressure even when water is being supplied, leaving them susceptible to intrusion from sewage, soil, or groundwater. Households with a non-continuous supply must collect and store water, presenting more opportunities for recontamination. Upgrading to a continuous water supply, while an obvious solution to these challenges, is currently out of reach for many resource-constrained utilities. Despite its widespread prevalence, there are few data on the mechanisms causing contamination in an intermittent supply and the frequency with which it occurs. Understanding the impact of intermittent operation on water quality can lead to strategies to improve access to safe piped water for the millions of people currently served by these systems. We collected over 100 hours of continuous measurements of pressure and physico-chemical water quality indicators and tested over 1,000 grab samples for indicator bacteria over 14 months throughout the distribution system in Hubli-Dharwad, India. This data set is used to explore and explain the mechanisms influencing water quality when piped water is provided for a few hours every 3-5 days. These data indicate that contamination occurs along the distribution system as water travels from the treatment plant to reservoirs and through intermittently supplied pipes to household storage containers, while real

  17. A Probabilistic Approach for Predicting Average Slug Frequency in Horizontal Gas/Liquid Pipe Flow

    Directory of Open Access Journals (Sweden)

    Kadri U.

    2013-02-01

    Full Text Available In this paper, we present a model for predicting the average slug frequency in horizontal gas/liquid pipe flow. The model considers the probability of slug formation if slugs are triggered at the antinodes of a sinusoidal perturbation, along the pipe at the frequency of oscillation of the interface. A slug is assumed to form if and only if triggered at a space-time far enough from existing slugs. The probability of forming slugs is found to decrease with distance from the inlet, since the downstream passage of existing slugs prevents the formation of new slugs. Predictions by the model are compared with air/water, freon/water and air/oil measurements found in literature, with a satisfactory agreement. However, a deviation from measurements is observed when considering high viscosity liquid. The model contributes to the prediction of slug flow regime and can act as a guideline toward the design of gas/liquid horizontal pipe flow.

  18. Efficient simulation of gas-liquid pipe flows using a generalized population balance equation coupled with the algebraic slip model

    KAUST Repository

    Icardi, Matteo

    2014-09-01

    The inhomogeneous generalized population balance equation, which is discretized with the direct quadrature method of moment (DQMOM), is solved to predict the bubble size distribution (BSD) in a vertical pipe flow. The proposed model is compared with a more classical approach where bubbles are characterized with a constant mean size. The turbulent two-phase flow field, which is modeled using a Reynolds-Averaged Navier-Stokes equation approach, is assumed to be in local equilibrium, thus the relative gas and liquid (slip) velocities can be calculated with the algebraic slip model, thereby accounting for the drag, lift, and lubrication forces. The complex relationship between the bubble size distribution and the resulting forces is described accurately by the DQMOM. Each quadrature node and weight represents a class of bubbles with characteristic size and number density, which change dynamically in time and space to preserve the first moments of the BSD. The predictions obtained are validated against previously published experimental data, thereby demonstrating the advantages of this approach for large-scale systems as well as suggesting future extensions to long piping systems and more complex geometries. © 2014 Elsevier Inc.

  19. Applied multiphase flow in pipes and flow assurance oil and gas production

    CERN Document Server

    Al-Safran, Eissa M

    2017-01-01

    Applied Multiphase Flow in Pipes and Flow Assurance - Oil and Gas Production delivers the most recent advancements in multiphase flow technology while remaining easy to read and appropriate for undergraduate and graduate petroleum engineering students. Responding to the need for a more up-to-the-minute resource, this highly anticipated new book represents applications on the fundamentals with new material on heat transfer in production systems, flow assurance, transient multiphase flow in pipes and the TUFFP unified model. The complex computation procedure of mechanistic models is simplified through solution flowcharts and several example problems. Containing over 50 solved example problems and 140 homework problems, this new book will equip engineers with the skills necessary to use the latest steady-state simulators available.

  20. Better Water Demand and Pipe Description Improve the Distribution Network Modeling Results

    Science.gov (United States)

    Distribution system modeling simplifies pipe network in skeletonization and simulates the flow and water quality by using generalized water demand patterns. While widely used, the approach has not been examined fully on how it impacts the modeling fidelity. This study intends to ...

  1. IRON TUBERCULATION: PHYSIO-CHEMICAL CHARACTERIZATION OF A SINGLE PIPE FROM A DRINKING WATER DISTRIBUTION SYSTEM

    Science.gov (United States)

    The nature of iron tubercles inside unlined iron pipes of drinking water distribution systems are influenced by water quality and therefore susceptible to changes in water chemistry. The underlying assumption is that tubercles in a system have similar physio-chemical properties. ...

  2. Trends in natural gas distribution and measurements

    International Nuclear Information System (INIS)

    Crone, C.F.A.

    1993-01-01

    On the occasion of the GAS EXPO 93, to be held from 13-15 October 1993 in Amsterdam, Netherlands, an overview is given of trends in the distribution of natural gas and the measuring of natural gas, as noted by experts from the energy utilities, GASTEC and Gasunie in the Netherlands. With regard to the natural gas distribution trends attention is paid to synthetic materials, the environmental effects, maintenance, underground natural gas pressure control, horizontal drilling (no-dig techniques), and other trends. With regard to natural gas metering trends brief discussions are given of the direct energy meter, the search for a new gas meter in households, telemetering, improving the accuracy of the gas meters by means of electronics, on the spot calibration of large gas meters, the use of an online chromatograph to determine the calorific value, the development of a calibration instrument, the so-called piston prover, to measure large quantities of natural gas, the recalibration of natural gas stations, the ultrasonic gas meter, and finally the quality of the natural gas supply. 1 fig., 11 ills

  3. Residual stress distribution in carbon steel pipe welded joint measured by neutron diffraction

    International Nuclear Information System (INIS)

    Hayashi, Makoto; Ishiwata, Masayuki; Morii, Yukio; Minakawa, Nobuaki

    2000-01-01

    In order to estimate crack growth behavior of fatigue and stress corrosion cracking in pipes, the residual stress distribution near the pipe weld region has to be measured through the wall thickness. Since the penetration depth of neutron is deep enough to pass through the thick pipe wall, the neutron diffraction technique for the residual stress measurement is effective for this purpose. At the first step the residual stress distribution near the weld region in a butt-welded carbon steel pipe was measured by the neutron diffraction. Significant stresses extended only to a distance of 30 mm from the center of the weld. The major tensile stresses occurred in the hoop direction in the fusion and heat affected zones of the weldment, and they attained a level greater than 200 MPa through the thickness. While the axial residual stress at the inside surface was 50 MPa, the stress at the outside surface was -100 MPa. The comparison of residual stress distributions measured by the neutron diffraction, the X-ray diffraction and the strain gauge method reveals that the neutron diffraction is the most effective for measuring the residual stress inside the structural components. (author)

  4. Practical aspects of acoustic plastic pipe location

    Energy Technology Data Exchange (ETDEWEB)

    Huebler, J.E.; Campbell, B.K. [Institute of Gas Technology, Chicago, IL (United States); Ching, G.K. [Southern California Gas Co. (United States)

    1993-12-31

    Many gas distribution company operation and maintenance activities require precise knowledge of the location of buried plastic piping. Plastic pipe cannot be located if the tracer wire is gone or was never installed. Under sponsorship of the Southern California Gas Company, IGT successfully demonstrated an acoustic plastic pipe location technique and is developing the technique into a practical field instrument an acoustic signal is injected directly into the gas at a service. The acoustic signal travels in the gas in the pipes, not in the pipe wall. As the acoustic wave travels along the pipe, some of the sound radiates from the pipe through the soil to the surface of the ground. An array of sensors on the surface of the ground perpendicular to the pipe detects the acoustic signal, thereby locating the Pipe. Two different acoustic measurements are used. The first measurement locates the pipe to within {plus_minus} 3-ft. Then the second technique determines the location of the pipe to within {plus_minus} 6-in.

  5. Factors controlling the spatial distribution of soil piping erosion on loess-derived soils: A case study from central Belgium

    Science.gov (United States)

    Verachtert, E.; Van Den Eeckhaut, M.; Poesen, J.; Deckers, J.

    2010-06-01

    Collapsible loess-derived soils are prone to soil piping erosion, where enlargement of macropores may lead to a subsurface pipe network and eventually to soil collapse and gully development. This study aims at understanding the main factors controlling spatial patterns of piping in loess-derived soils under a temperate climate. To map the spatial distribution of piping and identify the environmental controls on its distribution, a regional survey was carried out in a 236 km 2 study area in the Flemish Ardennes (Belgium). Orthophotos taken at optimal field conditions (winter) were analyzed to detect piping in open landscapes and ground thruthing was systematically done through field surveys. In total, 137 parcels having 560 collapsed pipes were mapped. Dimensions of the sinkholes and local slope gradient were measured in the field and topographical variables were derived from LiDAR data. Land use plays an important role as 97% of the sites with piping are found under pasture. The probability of piping increases rapidly on hillslopes with gradients exceeding 8% and with a concave profile and plan curvature, enhancing subsurface flow concentration. The zones with soil profiles on shallow loess over a relatively thin layer of homogeneous blue massive clays (Aalbeke Member) are most prone to piping. Soil characteristics are of less importance to explain piping occurrence. Furthermore, the topographical threshold line indicating the critical slope gradient for a given contributing drainage area was determined. This threshold line (negative power relation) is similar to the threshold line for shallow gully initiation.

  6. Environmentally Assisted Cracking of Drill Pipes in Deep Drilling Oil and Natural Gas Wells

    Science.gov (United States)

    Ziomek-Moroz, M.

    2012-06-01

    Corrosion fatigue (CF), hydrogen induced cracking (HIC) and sulfide stress cracking (SSC), or environmentally assisted cracking (EAC) have been identified as the most challenging causes of catastrophic brittle fracture of drill pipes during drilling operations of deep oil and natural gas wells. Although corrosion rates can be low and tensile stresses during service can be below the material yield stress, a simultaneous action between the stress and corrosive environment can cause a sudden brittle failure of a drill component. Overall, EAC failure consists of two stages: incubation and propagation. Defects, such as pits, second-phase inclusions, etc., serve as preferential sites for the EAC failure during the incubation stage. Deep oil and gas well environments are rich in chlorides and dissolved hydrogen sulfide, which are extremely detrimental to steels used in drilling operations. This article discusses catastrophic brittle fracture mechanisms due to EAC of drill pipe materials, and the corrosion challenges that need to be overcome for drilling ultra-deep oil and natural gas wells.

  7. A Lagrangian Slug Capturing Scheme for Gas-Liquid Flows in Pipes

    Energy Technology Data Exchange (ETDEWEB)

    Renault, Fabien

    2007-06-15

    In this thesis a new Lagrangian numerical scheme for the simulation of gas-liquid flows in pipelines is presented. Based on an approximate two-fluid model, this new scheme, called LASSI (Lagrangian Approximate Scheme for Slug Initiation) is dedicated to the modelling of the transition between stratified and slug flow. It is able to capture directly the slug initiation process and to track the motion of every single slug in the pipe without numerical diffusion. It can thus be qualified as a slug capturing and slug tracking scheme

  8. Residual stress distribution in carbon steel pipe welded joints measured by neutron diffraction

    International Nuclear Information System (INIS)

    Hayashi, Makoto; Ishiwata, Masayuki; Morii, Yukio; Minakawa, Nobuaki.

    1996-01-01

    Three dimensional residual stress distributions in a 4 inch diameter carbon steel pipe welded joint were measured by neutron diffraction technique. The results showed that the residual stress distributed near the weld metal, namely within about 30mm. The major tensile stresses occurred in the hoop direction in the fusion and heat affected zones of the weldment, and they attained a level greater than 200 MPa throughout the pipe wall thickness. While the axial residual stress at the inside surface was 40 MPa, the stress at the outside surface was -100 MPa. These residual stress distributions were compared with those measured by the X-ray diffraction technique and strain gauge method, and they agreed with each other. (author)

  9. Development of acoustic flow instruments for solid/gas pipe flows

    International Nuclear Information System (INIS)

    Sheen, S.H.; Raptis, A.C.

    1986-05-01

    Two nonintrusive acoustic flow sensing techniques are reported. One technique, passive in nature, simply measures the bandpassed acoustic noise level produced by particle/particle and particle/wall collisions. The noise levels, given in true RMS voltages or in autocorrelations, show a linear relationship to particle velocity but increase with solid concentration. Therefore, the passive technique requires calibration and a separate measure of solid concentration before it can be used to monitor the particle velocity. The second technique is based on the active cross-correlation principle. It measures particle velocity directly by correlating flow-related signatures at two sensing stations. The velocity data obtained by this technique are compared with measurements by a radioactive-particle time-of-flight (TOF) method. A multiplier of 1.53 is required to bring the acoustic data into agreement with the radioactive TOF result. The difference may originate from the difference in flow fields where particles are detected. The radioactive method senses particles mainly in the turbulent region and essentially measures average particle velocity across the pipe, while the acoustic technique detects particles near the pipe wall, and so measures the particle velocity in the viscous sublayer. Both techniques were tested in flows of limestone and air and 1-mm glass beads and air at the Argonne National Laboratory Solid/Gas Test Facility (SGFTF). The test matrix covered solid velocities of 20 to 30 m/s in a 2-in. pipe and solid-to-gas loading ratios of 6 to 22. 37 refs., 19 figs., 4 tabs

  10. Excellent impact performance of PVC pipeline materials in gas distribution networks after many years of service (CD-rom)

    OpenAIRE

    Visser, Roy; Hermkens, R.M.J.; Wolters, Mannes; Weller, J.; Warnet, Laurent; Beckervordersandforth, C.; Verberg, G.H.B.; Kramer, M.

    2008-01-01

    It has been about fifty years ago since the first unplasticized poly(vinyl chloride) (uPVC) pipes were installed for use in gas distribution purposes. Currently, about 22,500 km of uPVC is still in use in the Dutch gas distribution network. The pipes were originally designed for a lifetime of 50 years, but due to positive experiences the question arises if (and how long) the lifetime can be extended without any concessions to safety. This is supported by the data of leak surveys presented in ...

  11. Plastic strain and residual stress distributions in an AISI 304 stainless steel BWR pipe weld

    Science.gov (United States)

    Saukkonen, Tapio; Aalto, Miikka; Virkkunen, Iikka; Ehrnstén, Ulla; Hänninen, Hannu

    In AISI 304 stainless steel pipe welds weld shrinkage causes large variations in residual plastic strain in different parts of the weld metal and heat-affected zone (HAZ). The amount of strain was analyzed by EBSD quantitatively by comparing the intra-grain misorientations to the calibration curve. Highest degrees of plastic strain (10...20%) were detected in the HAZ close to the root area of a prototypical BWR plant weld. Strain in the weld metal varies in the different directions of solidification, being high in the weld bead boundaries and near the fusion lines. Preliminary studies of the effects of mechanical and elastic anisotropy of the weld metal microstructure on the grain size level were performed by EBSD and nanoindentation. The residual stress distribution in the same weld cross-section was determined by a contour method. The residual strain and stress distributions are superimposed and EAC susceptibility of various areas of the pipe weld is evaluated and discussed.

  12. Investigation of the specific mass flow rate distribution in pipes supplied with a pulsating flow

    International Nuclear Information System (INIS)

    Olczyk, Aleksander

    2009-01-01

    A pulsating flow is typical of inlet and exhaust pipes of internal combustion engines and piston compressors. Unsteady flow phenomena are especially important in the case of turbocharged engines, because dynamic effects occurring in the exhaust pipe can affect turbine operation conditions and performance. One of the basic parameters describing the unsteady flow is a transient mass flow rate related to the instantaneous flow velocity, which is usually measured by means of hot-wire anemometers. For the flowing gas, it is more appropriate to analyze the specific mass flow rate φ m = ρv, which takes into account also variations in the gas density. In order to minimize the volume occupied by measuring devices in the control section, special double-wire sensors for the specific mass flow rate (CTA) and temperature (CCT) measurement were applied. The article describes procedures of their calibration and measurement. Different forms of calibration curves are analyzed as well in order to match the approximation function to calibration points. Special attention is paid to dynamic phenomena related to the resonance occurring in a pipe for characteristic frequencies depending on the pipe length. One of these phenomena is a reverse flow, which makes it difficult to interpret properly the recorded CTA signal. Procedures of signal correction are described in detail. To verify the measurements, a flow field investigation was carried out by displacing probes radially and determining the profiles of the specific mass flow rate under the conditions of a steady and pulsating flow. The presence and general features of a reverse flow, which was identified experimentally, were confirmed by 1-D unsteady flow calculations.

  13. Numerical simulations and correlations on the coal -conveying gas flow in pipe for fluidized -bed coal gasification facility

    International Nuclear Information System (INIS)

    Lee, Chan; Lee, Jin Wook; Kwon, Tae Wan; Kim, Gyoo Tae

    2014-01-01

    CFD modeling and simulation are made on the key flow elements, vertical, horizontal pipes and elbow pipes , used in the pneumatic coal -transport system of fluidized -bed gasification test facility. The coal- gas flow inside the flow elements are modeled by combining Reynolds -stress Averaged Navier- Stokes equations Solver (RANS), k- ε turbulence model and Discrete Phase Model (DPM) in the ANSYS Fluent code. Using the developed coal -gas flow analysis model, computations are carried out to investigate the gas flow path, the coal particle behavior and the pressure loss characteristics in flow element at various coal/ gas loading ratio and coal mass flux. The present prediction results show the coal -gas flow behavior of each flow element is changed from dilute -flow to dense -flow pattern at a specific coal/gas loading ratio where pressure loss is abruptly increased. From the numerical results, the present study also provides the limiting coal/gas loading conditions to secure stable coal feeding and the correlations for pressure losses in horizontal, vertical and elbow pipes, which can be suitable for the design guidelines of actual fluidized -bed coal gasification. Key words : Pneumatic Coal -Transport; Coal -Gas Flow, Dense Phase Flow; Dilute Phase Flow; Pressure Loss; Coal/Gas Loading Ratio; Correlation

  14. Prediction of gas volume fraction in fully-developed gas-liquid flow in a vertical pipe

    Energy Technology Data Exchange (ETDEWEB)

    Islam, A.S.M.A.; Adoo, N.A.; Bergstrom, D.J., E-mail: nana.adoo@usask.ca [University of Saskatchewan, Department of Mechanical Engineering, Saskatoon, SK (Canada); Wang, D.F. [Canadian Nuclear Laboratories, Chalk River, ON (Canada)

    2015-07-01

    An Eulerian-Eulerian two-fluid model has been implemented for the prediction of the gas volume fraction profile in turbulent upward gas-liquid flow in a vertical pipe. The two-fluid transport equations are discretized using the finite volume method and a low Reynolds number κ-ε turbulence model is used to predict the turbulence field for the liquid phase. The contribution to the effective turbulence by the gas phase is modeled by a bubble induced turbulent viscosity. For the fully-developed flow being considered, the gas volume fraction profile is calculated using the radial momentum balance for the bubble phase. The model potentially includes the effect of bubble size on the interphase forces and turbulence model. The results obtained are in good agreement with experimental data from the literature. The one-dimensional formulation being developed allows for the efficient assessment and further development of both turbulence and two-fluid models for multiphase flow applications in the nuclear industry. (author)

  15. Variation behavior of residual stress distribution by manufacturing processes in welded pipes of austenitic stainless steel

    International Nuclear Information System (INIS)

    Ihara, Ryohei; Hashimoto, Tadafumi; Mochizuki, Masahito

    2012-01-01

    Stress corrosion cracking (SCC) has been observed near heat affected zone (HAZ) of primary loop recirculation pipes made of low-carbon austenitic stainless steel type 316L in the nuclear power plants. For the non-sensitization material, residual stress is the important factor of SCC, and it is generated by machining and welding. In the actual plants, welding is conducted after machining as manufacturing processes of welded pipes. It could be considered that residual stress generated by machining is varied by welding as a posterior process. This paper presents residual stress variation due to manufacturing processes of pipes using X-ray diffraction method. Residual stress distribution due to welding after machining had a local maximum stress in HAZ. Moreover, this value was higher than residual stress generated by welding or machining. Vickers hardness also had a local maximum hardness in HAZ. In order to clarify hardness variation, crystal orientation analysis with EBSD method was performed. Recovery and recrystallization were occurred by welding heat near the weld metal. These lead hardness decrease. The local maximum region showed no microstructure evolution. In this region, machined layer was remained. Therefore, the local maximum hardness was generated at machined layer. The local maximum stress was caused by the superposition effect of residual stress distributions due to machining and welding. Moreover, these local maximum residual stress and hardness are exceeded critical value of SCC initiation. In order to clarify the effect of residual stress on SCC initiation, evaluation including manufacturing processes is important. (author)

  16. Temporal Variations in the Abundance and Composition of Biofilm Communities Colonizing Drinking Water Distribution Pipes

    Science.gov (United States)

    Kelly, John J.; Minalt, Nicole; Culotti, Alessandro; Pryor, Marsha; Packman, Aaron

    2014-01-01

    Pipes that transport drinking water through municipal drinking water distribution systems (DWDS) are challenging habitats for microorganisms. Distribution networks are dark, oligotrophic and contain disinfectants; yet microbes frequently form biofilms attached to interior surfaces of DWDS pipes. Relatively little is known about the species composition and ecology of these biofilms due to challenges associated with sample acquisition from actual DWDS. We report the analysis of biofilms from five pipe samples collected from the same region of a DWDS in Florida, USA, over an 18 month period between February 2011 and August 2012. The bacterial abundance and composition of biofilm communities within the pipes were analyzed by heterotrophic plate counts and tag pyrosequencing of 16S rRNA genes, respectively. Bacterial numbers varied significantly based on sampling date and were positively correlated with water temperature and the concentration of nitrate. However, there was no significant relationship between the concentration of disinfectant in the drinking water (monochloramine) and the abundance of bacteria within the biofilms. Pyrosequencing analysis identified a total of 677 operational taxonomic units (OTUs) (3% distance) within the biofilms but indicated that community diversity was low and varied between sampling dates. Biofilms were dominated by a few taxa, specifically Methylomonas, Acinetobacter, Mycobacterium, and Xanthomonadaceae, and the dominant taxa within the biofilms varied dramatically between sampling times. The drinking water characteristics most strongly correlated with bacterial community composition were concentrations of nitrate, ammonium, total chlorine and monochloramine, as well as alkalinity and hardness. Biofilms from the sampling date with the highest nitrate concentration were the most abundant and diverse and were dominated by Acinetobacter. PMID:24858562

  17. Distribution of gas from Canaport LNG

    International Nuclear Information System (INIS)

    Thompson, W.

    2006-01-01

    Construction of the Canaport Liquefied Natural Gas (LNG) project will begin in 2006. Public consultations are currently being held for the 145 km pipeline from Canaport to Bailleyville, Maine. It is expected that both the facility and the pipeline will be operational by 2008. This presentation provided details of the New Brunswick (NB) Department of Energy's (DOE) regulatory oversight of the Canaport Liquefied Natural Gas (LNG) project. The DOE is responsible for ensuring diversity and security of supply; economic efficiency; economic development opportunities and protection of the environment. The Canaport LNG facility will provide an additional 500 to 600 temporary jobs over a 2 to 3 year period, as well as 20 full-time jobs once the plant is operational. Tax revenues, access roads and the construction of a pipeline to Bailleyville, Maine will also have positive impacts on the NB economy. The facility will provide a secure long term supply of natural gas for the region. In order to support its energy goals, the DOE has proposed amendments to provide for the distribution of gas from the plant to NB customers. A proposed LNG franchise to allow for direct distribution of gas from the LNG plant to customers was discussed. Issues concerning the Gas Distribution Act and the New Pipeline Act of 2006 were also examined. It was concluded that public consultations are currently being held for the 145 km pipeline, and that both the facility and the pipeline are expected to be operational by 2008. refs., tabs., figs

  18. 77 FR 32626 - Transcontinental Gas Pipe Line Company, LLC; Notice of Intent To Prepare an Environmental Impact...

    Science.gov (United States)

    2012-06-01

    ... at this time. You must wait until the Commission receives a formal application for the project... Gas Pipe Line Company, LLC; Notice of Intent To Prepare an Environmental Impact Statement for the Planned Rockaway Delivery Lateral Project, Request for Comments on Environmental Issues, and Notice of...

  19. RESIDUAL RISK ASSESSMENT: GAS DISTRIBUTION STAGE ...

    Science.gov (United States)

    This document describes the residual risk assessment for the Gas Distribution Stage 1 souce category. For stationary sources, section 112 (f) of the Clean Air Act requires EPA to assess risks to human health and the environment following implementation of technology-based control standards. If these technology-based control standards do not provide an ample margin of safety, then EPA is required to promulgate addtional standards. This document describes the methodology and results of the residual risk assessment performed for the Gas Distribution Stage 1 source category. The results of this analyiss will assist EPA in determining whether a residual risk rule for this source category is appropriate.

  20. Economic feasibility of pipe storage and underground reservoir storage options for power-to-gas load balancing

    International Nuclear Information System (INIS)

    Budny, Christoph; Madlener, Reinhard; Hilgers, Christoph

    2015-01-01

    Highlights: • Study of cost effectiveness of power-to-gas and storage of H 2 and renewable methane. • NPV analysis and Monte Carlo simulation to address fuel and electricity price risks. • Gas sale is compared with power and gas market arbitrage and balancing market gains. • Power-to-gas for linking the balancing markets for power and gas is not profitable. • Pipe storage is the preferred option for temporal arbitrage and balancing energy. - Abstract: This paper investigates the economic feasibility of power-to-gas (P2G) systems and gas storage options for both hydrogen and renewable methane. The study is based on a techno-economic model in which the net present value (NPV) method and Monte Carlo simulation of risks and price forward curves for the electricity and the gas market are used. We study three investment cases: a Base Case where the gas is directly sold in the market, a Storage & Arbitrage Case where temporal arbitrage opportunities between the electricity and the gas market are exploited, and a Storage & Balancing Case where the balancing markets (secondary reserve market for electricity, external balancing market for natural gas) are addressed. The optimal type and size of different centralized and decentralized storage facilities are determined and compared with each other. In a detailed sensitivity and cost analysis, we identify the key factors which could potentially improve the economic viability of the technological concepts assessed. We find that the P2G system used for bridging the balancing markets for power and gas cannot be operated profitably. For both, temporal arbitrage and balancing energy, pipe storage is preferred. Relatively high feed-in tariffs (100 € MW −1 for hydrogen, 130 € MW −1 for methane) are required to render pipe storage for P2G economically viable

  1. Analysis of pipe stress using CAESAR II code

    International Nuclear Information System (INIS)

    Sitandung, Y.B.; Bandriyana, B.

    2002-01-01

    Analysis of this piping stress with the purpose of knowing stress distribution piping system in order to determine pipe supports configuration. As an example of analysis, Gas Exchanger to Warm Separator Line was chosen with, input data was firstly prepared in a document, i.e. piping analysis specification that its content named as pipe characteristics, material properties, operation conditions, guide equipment's and so on. Analysis result such as stress, load, displacement and the use support type were verified based on requirements in the code, standard, and regularities were suitable with piping system condition analyzed. As the proof that piping system is in safety condition, it can be indicated from analysis results (actual loads) which still under allowable load. From the analysis steps that have been done CAESAR II code fulfill requirements to be used as a tool of piping stress analysis as well as nuclear and non nuclear installation piping system

  2. Detection of Escherichia coli in Biofilms from Pipe Samples and Coupons in Drinking Water Distribution Networks▿

    Science.gov (United States)

    Juhna, T.; Birzniece, D.; Larsson, S.; Zulenkovs, D.; Sharipo, A.; Azevedo, N. F.; Ménard-Szczebara, F.; Castagnet, S.; Féliers, C.; Keevil, C. W.

    2007-01-01

    Fluorescence in situ hybridization (FISH) was used for direct detection of Escherichia coli on pipe surfaces and coupons in drinking water distribution networks. Old cast iron main pipes were removed from water distribution networks in France, England, Portugal, and Latvia, and E. coli was analyzed in the biofilm. In addition, 44 flat coupons made of cast iron, polyvinyl chloride, or stainless steel were placed into and continuously exposed to water on 15 locations of 6 distribution networks in France and Latvia and examined after 1 to 6 months exposure to the drinking water. In order to increase the signal intensity, a peptide nucleic acid (PNA) 15-mer probe was used in the FISH screening for the presence or absence of E. coli on the surface of pipes and coupons, thus reducing occasional problems of autofluorescence and low fluorescence of the labeled bacteria. For comparison, cells were removed from the surfaces and examined with culture-based or enzymatic (detection of β-d-glucuronidase) methods. An additional verification was made by using PCR. Culture method indicated presence of E. coli in one of five pipes, whereas all pipes were positive with the FISH methods. E. coli was detected in 56% of the coupons using PNA FISH, but no E. coli was detected using culture or enzymatic methods. PCR analyses confirmed the presence of E. coli in samples that were negative according to culture-based and enzymatic methods. The viability of E. coli cells in the samples was demonstrated by the cell elongation after resuscitation in low-nutrient medium supplemented with pipemidic acid, suggesting that the cells were present in an active but nonculturable state, unable to grow on agar media. E. coli contributed to ca. 0.001 to 0.1% of the total bacterial number in the samples. The presence and number of E. coli did not correlate with any of physical and/or chemical characteristic of the drinking water (e.g., temperature, chlorine, or biodegradable organic matter concentration

  3. Investigation of gas-phase decontamination of internally radioactively contaminated gaseous diffusion process equipment and piping

    International Nuclear Information System (INIS)

    Bundy, R.D.; Munday, E.B.

    1991-01-01

    Construction of the gaseous diffusion plants (GDPs) was begun during World War 2 to produce enriched uranium for defense purposes. These plants, which utilized UF 6 gas, were used primarily for this purpose through 1964. From 1959 through 1968, production shifted primarily to uranium enrichment to supply the nuclear power industry. Additional UF 6 -handling facilities were built in feed and fuel-processing plants associated with the uranium enrichment process. Two of the five process buildings at Oak ridge were shut down in 1964. Uranium enrichment activities at Oak Ridge were discontinued altogether in 1985. In 1987, the Department of Energy (DOE) decided to proceed with a permanent shutdown of the Oak Ridge Gaseous Diffusion Plant (ORGDP). DOE intends to begin decommissioning and decontamination (D ampersand D) of ORGDP early in the next century. The remaining two GDPs are expected to be shut down during the next 10 to 40 years and will also require D ampersand D, as will the other UF 6 -handling facilities. This paper presents an investigation of gas- phase decontamination of internally radioactively contaminated gaseous diffusion process equipment and piping using powerful fluorinating reagents that convert nonvolatile uranium compounds to volatile UF 6 . These reagents include ClF 3 , F 2 , and other compounds. The scope of D ampersand D at the GDPs, previous work of gas-phase decontamination, four concepts for using gas-phase decontamination, plans for further study of gas-phase decontamination, and the current status of this work are discussed. 13 refs., 15 figs

  4. The Numerical Simulation of the Shock Wave of Coal Gas Explosions in Gas Pipe*

    Science.gov (United States)

    Chen, Zhenxing; Hou, Kepeng; Chen, Longwei

    2018-03-01

    For the problem of large deformation and vortex, the method of Euler and Lagrange has both advantage and disadvantage. In this paper we adopt special fuzzy interface method(volume of fluid). Gas satisfies the conditions of conservation equations of mass, momentum, and energy. Based on explosion and three-dimension fluid dynamics theory, using unsteady, compressible, inviscid hydrodynamic equations and state equations, this paper considers pressure gradient’s effects to velocity, mass and energy in Lagrange steps by the finite difference method. To minimize transport errors of material, energy and volume in Finite Difference mesh, it also considers material transport in Euler steps. Programmed with Fortran PowerStation 4.0 and visualized with the software designed independently, we design the numerical simulation of gas explosion with specific pipeline structure, check the key points of the pressure change in the flow field, reproduce the gas explosion in pipeline of shock wave propagation, from the initial development, flame and accelerate the process of shock wave. This offers beneficial reference and experience to coal gas explosion accidents or safety precautions.

  5. Unknown plant de-construction hazard -- Toxic COS and CS2 gas from torch cutting of pipe

    International Nuclear Information System (INIS)

    Martin, H.L.; Nutt, A.W.; Myers, B.L.; Hightower, J.O.

    1994-01-01

    An employee exhibited signs of illness after apparently inhaling fumes generated from a pipe that had been cut with a cutting torch. Identification and quantification of the hazardous air emission for reduction of risk via the Department of Energy Class B Investigation are described in this case study. The old hydrogen sulfide gas flare pipe in the heavy water plant of the Savannah River Site has been abandoned with one end open to atmosphere for almost twenty years. The pipe was being removed and cut into sections for disposal during an asbestos abatement project. It contained ash like corrosion deposits that smolder after torch cutting. Investigation revealed that burning of carbon and sulfur in the oxygen deficient atmosphere in the ash generated carbonyl sulfide (COS) and carbon disulfide (CS 2 ) gas, which vented when the pipe was moved by the injured construction rigger. This is believed to be the first well documented exposure and response of a human to high concentration COS gas. Sulfur dioxide (SO 2 ) gas is also generated during the cutting. SO 2 is almost impossible to inhale and has apparently prevented a similar injury during the cutting. SO 2 is almost impossible to inhale and has apparently prevented a similar injury during the many years of US and Canadian heavy water plant de-construction experience. Immediate water quench of the smoldering ash after each cut has eliminated the hazard of residual COS and CS 2 gas. This previously unrecognized industrial hazard may be encountered by other chemical and petroleum industries during torch cutting of pipes that contain similar deposits of iron oxide, iron sulfate, sulfur and carbon

  6. Optimal fund assignment and allocation models for pipe repair maintenance in leaky water distribution networks

    Science.gov (United States)

    Bach, Nguyen Luong; Fujiwara, Okitsugu; Luong, Huynh Trung

    2000-05-01

    In pipe repair maintenance operations for leaky water distribution networks in cities, it is usually the practice that whenever pipe leaks are detected, repair actions are undertaken until the funds assigned are exhausted. The allocation of limited repair funds to different pipe sections is normally done without careful quantitative analysis but according to an intuitive rule, whereby the section of the larger leak volume receives the larger share of funds. This paper proposes a new modeling approach to determine optimal repair fund allocation to different sections of a city. A basic periodic-review stochastic demand inventory model is first applied to ascertain the optimal funds to be assigned to a city under an assumption of no fund limitation. The model is then extended to determine the optimal allocation of the limited funds to different sections of a city. The models minimize the expected total system cost composed of repair cost, storage cost (of spare parts and materials), and penalty cost for water loss due to lack of funds. Numerical experiments are then conducted to illustrate the applicability of the proposed models, and the characteristics of the optimal solutions with regard to parameter variations are investigated. Data used in the numerical example are taken from actual data of the secondary network of Ho Chi Minh City in Vietnam.

  7. Thermoplastic materials in oil and gas applications: 30 years experience with polyamide 11 from offshore production to onshore distribution

    Energy Technology Data Exchange (ETDEWEB)

    Dang, Patrick; Werth, Michael [ATOFINA SA, Paris La Defense (France); Marchioni, Roger [ATOFINA Brasil, Rio Claro, SP (Brazil); Mason, James [ATOFINA Chemicals Inc., Philadelphia, PA (United States)

    2004-07-01

    For more than 30 years, the technical polymer Polyamide 11 is used for offshore oil and gas production as pressure sheath of flexible pipes or as tubing for offshore umbilicals. Comprehensive studies on polyamide 11 have been achieved in order to qualify it and use it with confidence. Specifications and technical reports established by API are an important step forward. The purpose of this paper is to present how lifetime prediction has been handled for two main applications of polyamide 11 in both upstream and downstream : offshore flexible pipes and gas distribution pipes. The first case is based on long term chemical ageing and the second on long term mechanical performances. Both cases show that Polyamide 11 is really the polymer of choice in oil and gas environments when performances and reliability are required. (author)

  8. Anomalous dissipation and kinetic-energy distribution in pipes at very high Reynolds numbers.

    Science.gov (United States)

    Chen, Xi; Wei, Bo-Bo; Hussain, Fazle; She, Zhen-Su

    2016-01-01

    A symmetry-based theory is developed for the description of (streamwise) kinetic energy K in turbulent pipes at extremely high Reynolds numbers (Re's). The theory assumes a mesolayer with continual deformation of wall-attached eddies which introduce an anomalous dissipation, breaking the exact balance between production and dissipation. An outer peak of K is predicted above a critical Re of 10^{4}, in good agreement with experimental data. The theory offers an alternative explanation for the recently discovered logarithmic distribution of K. The concept of anomalous dissipation is further supported by a significant modification of the k-ω equation, yielding an accurate prediction of the entire K profile.

  9. Analytical equation for outflow along the flow in a perforated fluid distribution pipe.

    Directory of Open Access Journals (Sweden)

    Huanfang Liu

    Full Text Available Perforated fluid distribution pipes have been widely used in agriculture, water supply and drainage, ventilation, the chemical industry, and other sectors. The momentum equation for variable mass flow with a variable exchange coefficient and variable friction coefficient was developed by using the momentum conservation method under the condition of a certain slope. The change laws of the variable momentum exchange coefficient and the variable resistance coefficient along the flow were analyzed, and the function of the momentum exchange coefficient was given. According to the velocity distribution of the power function, the momentum equation of variable mass flow was solved for different Reynolds numbers. The analytical solution contains components of pressure, gravity, friction and momentum and reflects the influence of various factors on the pressure distribution along the perforated pipe. The calculated results of the analytical solution were compared with the experimental values of the study by Jin et al. 1984 and Wang et al. 2001 with the mean errors 8.2%, 3.8% and 2.7%, and showed that the analytical solution of the variable mass momentum equation was qualitatively and quantitatively consistent with the experimental results.

  10. Geologic distributions of US oil and gas

    International Nuclear Information System (INIS)

    1992-01-01

    This publication presents nonproprietary field size distributions that encompass most domestic oil and gas fields at year-end 1989. These data are organized by geologic provinces as defined by the American Association of Petroleum Geologists' Committee on Statistics of Drilling (AAPG/CSD), by regional geographic aggregates of the AAPG/CSD provinces, and Nationally. The report also provides partial volumetric distributions of petroleum liquid and natural gas ultimate recoveries for three macro-geologic variables: principal lithology of the reservoir rock, principal trapping condition and geologic age of the reservoir rock, The former two variables are presented Nationally and by geographic region, in more detail than has heretofore been available. The latter variable is provided Nationally at the same level of detail previously available. Eighteen tables and 66 figures present original data on domestic oil and gas occurrence. Unfortunately, volumetric data inadequacy dictated exclusion of Appalachian region oil and gas fields from the study. All other areas of the United States known to be productive of crude oil or natural gas through year-end 1989, onshore and offshore, were included. It should be noted that none of the results and conclusions would be expected to substantively differ had data for the Appalachian region been available for inclusion in the study

  11. Study of quantification and distribution of explosive mixture in a confined space as a result of natural gas leak

    Directory of Open Access Journals (Sweden)

    Tulach Aleš

    2014-03-01

    Full Text Available The contribution deals with quantification of natural gas leak from a domestic low pressure pipe to a confined space in relation to formation of explosive concentration. Within the experiments, amount of leak gas was determined considering the character of pipe damage. Leakage coefficients, natural gas expansion and time before reaching the lower explosive limit of a gas-air mixture were taken. Conducted experiments were then modelled using CFD software and the results were verified. In numerical model, several models of flow were used and afterwards following issues were analysed: leakage velocity, spatial distribution of the mixture in a confined space, formation of concentration at the lower explosive limit etc. This work should contribute to better understanding of propagation and distribution of gaseous fuel mixtures in confined spaces and thereby significantly reduce the risk of fires or explosions or prevent them.

  12. Void fraction development in gas-liquid flow after a U-bend in a vertically upwards serpentine-configuration large-diameter pipe

    Science.gov (United States)

    Almabrok, Almabrok A.; Aliyu, Aliyu M.; Baba, Yahaya D.; Lao, Liyun; Yeung, Hoi

    2018-01-01

    We investigate the effect of a return U-bend on flow behaviour in the vertical upward section of a large-diameter pipe. A wire mesh sensor was employed to study the void fraction distributions at axial distances of 5, 28 and 47 pipe diameters after the upstream bottom bend. The study found that, the bottom bend has considerable impacts on up-flow behaviour. In all conditions, centrifugal action causes appreciable misdistribution in the adjacent straight section. Plots from WMS measurements show that flow asymmetry significantly reduces along the axis at L/D = 47. Regime maps generated from three axial locations showed that, in addition to bubbly, intermittent and annular flows, oscillatory flow occurred particularly when gas and liquid flow rates were relatively low. At this position, mean void fractions were in agreement with those from other large-pipe studies, and comparisons were made with existing void fraction correlations. Among the correlations surveyed, drift flux-type correlations were found to give the best predictive results.

  13. Controlled erosion in asbestos-cement pipe used in drinking water distribution systems

    Directory of Open Access Journals (Sweden)

    Mariana Ramos, P.

    1990-06-01

    Full Text Available Samples of asbestos-cement pipe used for drinking water conveyance, were submerged in distilled water, and subjected to two controlled erosive treatments, namely agitation (300 rpm for 60 min and ultrasound (47 kHz for 30 min. SEM was used to observe and compare the morphology of the new pipe with and without erosive treatment, and of samples taken from asbestos-cement pipes used in the distribution system of drinking water in Santiago city for 10 and 40-years of service. TEM was used to determine the concentration of asbestos fibers in the test water: 365 MFL and 1690 MFL (millions of fibers per litre as an agitation and result ultrasound, respectively. The erosive treatments by means of agitation or ultrasound applied to new asbestos-cement pipes used in the drinking water distribution system were evaluated as being equivalent to 4 and 10 years of service, respectively.

    Se sometió a dos tratamientos erosivos controlados uno por agitación (300 rpm, 60 min. y otro por ultrasonido (47 kHz, 30 min. a muestras de tubos de asbesto cemento, sumergidas en agua destilada, usados para el trasporte de agua potable. Con SEM se observó la morfología de muestras de tubos sin uso, con y sin tratamiento erosivo y la de muestras extraídas de tubos de asbesto cemento de la red de distribución de agua potable de ía ciudad de Santiago con 10 y 14 años de servicio. Con TEM se determinó la concentración de fibras de asbesto en el agua de ensayo: 365 MFL y 1690 MFL (millones de fibras por litro en agitación y ultrasonido, respectivamente. Se estimó en 4 y 10 años de servicio equivalente los tratamientos erosivos de agitación y ultrasonido, respectivamente en tubos de asbesto cemento empleados en la red de agua potable.

  14. The effect of white or grey PVC pipe and its joint solvents (primer and cement) on odour problems in drinking water distribution systems.

    Science.gov (United States)

    Wiesenthal, K E; Suffet, I H

    2007-01-01

    A study of the production of odour-causing compounds was conducted from the leaching of polyvinylchloride (PVC) pipe and its joints, primer and cement, into drinking water distribution systems. Flavour Profile Analysis (FPA), closed-loop stripping analysis--gas chromatography/mass spectrometry (CLSA-GC/MS) and sensory-GC analysis of white or grey PVC alone found no odour-causing compounds produced during the leaching experiments. FPA analysis of the PVC's primer and cement leached alone and/or when applied to grey or white PVC pipes produced a glue/varnish odour. A sweet/phenolic odour replaced the glue/varnish odour after the leached media were diluted with Milli-Q water to threshold odour intensity. Three compounds were responsible for the sweet/phenolic odour and were observed by sensoryGC analysis. The leaching study of the PVC pipe with its joint solvents (primer and cement) concluded that the original solvent compounds, and their reaction products that formed during the bonding process on the PVC pipe, were a primary source of the glue/varnish odour. The original compounds of the PVC primer and cement were not detected by CLSA-GC/MS, due to their high volatility during the CLSA extraction method and/or these compounds appeared in a solvent peak of the GC/MS analysis. However, the original primer and cement chemicals (acetone, tetrahydrofuran, methyl ethyl ketone, and cyclohexanone) had a glue/varnish odour. A total of nine odorous GC peaks were produced as reaction products from leaching of primer in water and white or grey PVC pipe with primer and cement, and white or grey PVC with primer only. None of these compounds were among the chemical ingredients in the original primer or cement. Four GC peaks with a sweet/phenolic odour were present due to the reaction products of the cement leached with white or grey PVC. None of these compounds were positively identified.

  15. Mixing at double-Tee junctions with unequal pipe sizes in water distribution systems

    Data.gov (United States)

    U.S. Environmental Protection Agency — Pipe flow mixing with various solute concentrations and flow rates at pipe junctions is investigated. The degree of mixing affects the spread of contaminants in a...

  16. Boundary element method applied to a gas-fired pin-fin-enhanced heat pipe

    Energy Technology Data Exchange (ETDEWEB)

    Andraka, C.E.; Knorovsky, G.A.; Drewien, C.A.

    1998-02-01

    The thermal conduction of a portion of an enhanced surface heat exchanger for a gas fired heat pipe solar receiver was modeled using the boundary element and finite element methods (BEM and FEM) to determine the effect of weld fillet size on performance of a stud welded pin fin. A process that could be utilized by others for designing the surface mesh on an object of interest, performing a conversion from the mesh into the input format utilized by the BEM code, obtaining output on the surface of the object, and displaying visual results was developed. It was determined that the weld fillet on the pin fin significantly enhanced the heat performance, improving the operating margin of the heat exchanger. The performance of the BEM program on the pin fin was measured (as computational time) and used as a performance comparison with the FEM model. Given similar surface element densities, the BEM method took longer to get a solution than the FEM method. The FEM method creates a sparse matrix that scales in storage and computation as the number of nodes (N), whereas the BEM method scales as N{sup 2} in storage and N{sup 3} in computation.

  17. Investigation and prediction of slug flow characteristics in highly viscous liquid and gas flows in horizontal pipes

    OpenAIRE

    Zhao, Y.; Lao, Liyun; Yeung, H.

    2015-01-01

    Slug flow characteristics in highly viscous liquid and gas flow are studied experimentally in a horizontal pipe with 0.074 m ID and 17 m length. Results of flow regime map, liquid holdup and pressure gradient are discussed and liquid viscosity effects are investigated. Applicable correlations which are developed to predict liquid holdup in slug body for low viscosity flow are assessed with high viscosity liquids. Furthermore, a mechanistic model is developed for predicting the characteristics...

  18. Measurement of gas-liquid two-phase flow in micro-pipes by a capacitance sensor.

    Science.gov (United States)

    Ji, Haifeng; Li, Huajun; Huang, Zhiyao; Wang, Baoliang; Li, Haiqing

    2014-11-26

    A capacitance measurement system is developed for the measurement of gas-liquid two-phase flow in glass micro-pipes with inner diameters of 3.96, 2.65 and 1.56 mm, respectively. As a typical flow regime in a micro-pipe two-phase flow system, slug flow is chosen for this investigation. A capacitance sensor is designed and a high-resolution and high-speed capacitance measurement circuit is used to measure the small capacitance signals based on the differential sampling method. The performance and feasibility of the capacitance method are investigated and discussed. The capacitance signal is analyzed, which can reflect the voidage variation of two-phase flow. The gas slug velocity is determined through a cross-correlation technique using two identical capacitance sensors. The simulation and experimental results show that the presented capacitance measurement system is successful. Research work also verifies that the capacitance sensor is an effective method for the measurement of gas liquid two-phase flow parameters in micro-pipes.

  19. Measurement of Gas-Liquid Two-Phase Flow in Micro-Pipes by a Capacitance Sensor

    Directory of Open Access Journals (Sweden)

    Haifeng Ji

    2014-11-01

    Full Text Available A capacitance measurement system is developed for the measurement of gas-liquid two-phase flow in glass micro-pipes with inner diameters of 3.96, 2.65 and 1.56 mm, respectively. As a typical flow regime in a micro-pipe two-phase flow system, slug flow is chosen for this investigation. A capacitance sensor is designed and a high-resolution and high-speed capacitance measurement circuit is used to measure the small capacitance signals based on the differential sampling method. The performance and feasibility of the capacitance method are investigated and discussed. The capacitance signal is analyzed, which can reflect the voidage variation of two-phase flow. The gas slug velocity is determined through a cross-correlation technique using two identical capacitance sensors. The simulation and experimental results show that the presented capacitance measurement system is successful. Research work also verifies that the capacitance sensor is an effective method for the measurement of gas liquid two-phase flow parameters in micro-pipes.

  20. Spinning pipe gas lens aberrations along the axis and in the boundary layer

    CSIR Research Space (South Africa)

    Mafusire, C

    2013-11-01

    Full Text Available When the walls of an open-ended horizontal steel pipe are heated before the pipe is rotated along its axis, the exchange of the expelled heated air with the incoming cooler air, sucked in along the axis, results in a medium capable of focusing a...

  1. Development, manufacturing and testing of a gas-loaded variable conductance methanol heat pipe

    Science.gov (United States)

    Vanbuggenum, R. I. J.; Daniels, D. H. W.

    1987-02-01

    The experimental technology required to measure the performance of moderate temperature heat pipes is presented. The heat pipe manufacturing process is described. The hydrodynamic characteristics of the porous structure inside the heat pipe envelope were examined using a specially developed test rig, based upon a steady-state evaporation test. A fully automated test facility was developed and validated by testing constant conductance and variable conductance heat pipes (VCHP). Theoretical performance predictions are illustrated in terms of pressure, depicted in 3D-plots, and compared with the test results of the heat pipe performance tests. The design of the VCHP was directed towards the verification of the VCHP mathematical model. The VCHP design is validated and ready for the final testing and model verification.

  2. Development options for the Dutch gas distribution grid in a changing gas market

    NARCIS (Netherlands)

    Weidenaar, Taede; Hoekstra, S.; Wolters, Mannes

    2011-01-01

    The Dutch gas distribution grid faces several changes in the near future. Among others, the share of green gas will grow, the interaction with the electricity distribution grid and local heat grids will increase, and the grid will transform from a mono-gas system to a multi-gas system. The gas

  3. Gas distribution and starbursts in shell galaxies

    Science.gov (United States)

    Weil, Melinda L.; Hernquist, Lars

    1993-01-01

    Detailed maps of most elliptical galaxies reveal that, whereas the greatest part of their luminous mass originates from a smooth distribution with a surface brightness approximated by a de Vaucouleurs law, a small percentage of their light is contributed by low surface brightness distortions termed 'fine structures'. The sharp-edged features called 'shells' are successfully reproduced by merger and infall models involving accretion from less massive companions. In this context, dwarf spheroidal and compact disk galaxies are likely progenitors of these stellar phenomena. However, it is probable that the sources of shell-forming material also contain significant amounts of gas. This component may play an important role in constraining the formation and evolution of shell galaxies. To investigate the effects of the gaseous component, numerical simulations were performed to study the tidal disruption of dwarf galaxies containing both gas and stars by more massive primaries, and the evolution of the ensuing debris. The calculations were performed with a hybrid N-body/hydrodynamics code. Collisionless matter is evolved using a conventional N-body technique and gas is treated using smoothed particle hydrodynamics in which self-gravitating fluid elements are represented as particles evolving according to Lagrangian hydrodynamic equations. An isothermal equation of state is employed so the gas remains at a temperature 104 K. Owing to the large mass ratio between the primary and companion, the primary is modeled as a rigid potential and the self-gravity of both galaxies is neglected.

  4. Mechanical Properties of High-Nb X80 Steel Weld Pipes for the Second West-to-East Gas Transmission Pipeline Project

    Directory of Open Access Journals (Sweden)

    Gui-ying Qiao

    2017-01-01

    Full Text Available The mechanical properties of steel pipe have great effects on the integrality and operation safety of gas transmission pipeline. In order to reduce the cost of the steel pipe, the high-Nb X80 pipeline steels with the different alloying systems have been used in the Second West-to-East Gas Transmission Pipeline Project. Nevertheless, an investigation into the effects of chemical composition on the mechanical properties of steel pipes is lacking. In this work, the chemical composition and mechanical properties of high-Nb X80 grade steel pipes with a diameter of ϕ1,219 mm and a wall thickness of 22 mm, which are coiled by steels manufactured by three mills, have been analyzed. Furthermore, the effects of chemical composition of the steels on the mechanical properties of the pipe body and weld joint were discussed.

  5. Distributed gas detection system and method

    Science.gov (United States)

    Challener, William Albert; Palit, Sabarni; Karp, Jason Harris; Kasten, Ansas Matthias; Choudhury, Niloy

    2017-11-21

    A distributed gas detection system includes one or more hollow core fibers disposed in different locations, one or more solid core fibers optically coupled with the one or more hollow core fibers and configured to receive light of one or more wavelengths from a light source, and an interrogator device configured to receive at least some of the light propagating through the one or more solid core fibers and the one or more hollow core fibers. The interrogator device is configured to identify a location of a presence of a gas-of-interest by examining absorption of at least one of the wavelengths of the light at least one of the hollow core fibers.

  6. Design and testing of a heat pipe gas combustion system for the STM4-120 Stirling engine

    Science.gov (United States)

    Khalili, K.; Godett, T. M.; Meijer, R. J.; Verhey, R. P.

    Evaporators of a novel geometry, designed to have a more compact size yet the same output as larger, conventional heat pipes, have been fabricated and tested. A technique was developed to calculate capillary pressure required inside the heat pipe. Several quarter- and full-scale evaporators were designed and successfully tested. The burner, film-cooled combustion chamber, and preheater were designed and tested separately. A complete heat pipe gas combustion system (HPGC) was tested, showing an efficiency of 89 percent was measured at 20 kWth. A film-cooled combustion chamber was tested with flame temperatures of 2200 C and wall temperatures below 1000 C using preheated air for film cooling. Also, a full-scale HPGC was tested at an excess of 95 kWth, showing efficiency in the range of 85 to 90 percent under steady-state conditions. Results of transient and startup tests, carried out to evaluate the performance of the heat pipe, all also reported.

  7. Gas Distribution in Shallow Packed Beds.

    Science.gov (United States)

    Parsons, Ian Miles

    Available from UMI in association with The British Library. Packed beds have many industrial applications and are increasingly used in the process industries due to their low pressure drop. Obtaining uniform gas distribution in such beds is of crucial importance in minimising operating costs and optimising plant performance. Since to some extent a packed bed acts as its own distributor the importance of obtaining uniform gas distribution has increased as aspect ratios (bed height to diameter) decrease. There is no rigorous design method for distributors due to a limited understanding of the fluid flow phenomena and in particular of the effect of the bed base/free fluid interface. This study is based on a combined theoretical and modelling approach. The Ergun Equation is used to determine the pressure drop over a bed where the flow is uni-directional. This equation has been used in a vectorial form so that it can be applied to maldistributed and multi -directional flows and has been realised in the Computational Fluid Dynamics code PHOENICS. The use of this equation and its application has been verified by modelling experimental measurements of maldistributed gas flows, where there is no free fluid/bed base interface. A novel, two-dimensional experiment has been designed to investigate the fluid mechanics of maldistributed gas flows in shallow packed beds. The results from this apparatus provide useful insights into the fluid mechanics of flow in and around a shallow packed bed and show the critical effect of the bed base. The PHOENICS/vectorial Ergun Equation model has been adapted to model this situation. The model has been improved by the inclusion of spatial voidage variations in the bed and the prescription of a novel bed base boundary condition. The flow in a curved bed section, which is three -dimensional in nature, is examined experimentally. The effect of the walls and the changes in gas direction on the gas flow are shown to be particularly significant

  8. Examination of the CLIC drive beam pipe design for thermal distortion caused by distributed beam loss

    CERN Document Server

    Johnson, C D

    1997-01-01

    Beam transport programs are widely used to estimate the distribution of power deposited in accelerator structures by particle beams, either intentionally as for targets or beam dumps or accidentally owing to beam loss incidents. While this is usually adequate for considerations of radiation safety, it does not reveal the expected temperature rise and its effect on structural integrity. To find this, thermal diffusion must be taken into account, requiring another step in the analysis. The method that has been proposed is to use the output of a transport program, perhaps modified, as input for a finite element analysis program that can solve the thermal diffusion equation. At CERN, the design of the CLIC drive beam pipe has been treated in this fashion. The power distribution produced in the walls by a distributed beam loss was found using the electron gamma shower code EGS4. The distribution of power density was then used to form the input for the finite element analysis program ANSYS, which was able to find t...

  9. The pipes for gas and oil pipelines mains one-sided high-speed welding

    Directory of Open Access Journals (Sweden)

    Сергій Вікторович Щетинін

    2016-11-01

    Full Text Available Electromagnetic theory of the undercuts formation under the arc magnetic field action according to which as welding speed increases cooling intensifies and arc diameter reduces, induction and magnetic pressure increase, pinch-effect amplifies, has been proved. The arc concentrates, heat input and the pool side edges electrical resistance reduce with the result that current through the side walls and a downward electromagnetic force, under the action of which the liquid metal flows from the pool edges, increase and the undercuts form. In high-speed welding a composite electrode as compared with the wire electrode the heat input into the side edges and their electrical resistance increase; current and induction at the pool side edges and the electromagnetic force decrease that providing the seams qualitative formation and confirming the electromagnetic theory of the undercuts. With welding speed increasing the weld pool molten metal crystallization rate increases in proportion to it, microstructure gets reduced and welding stresses decrease, that providing the welds joints toughness rise. By increasing welding speed due to deflection rearward the arc pressure decreases, the molten metal movement rate into the back part of the pool grows, that resulting in the molten metal hydrodynamic pressure reduction. Due to simultaneous reduction of the arc pressure, of the downward electromagnetic force and of the molten metal hydrodynamic pressure, the crystallization rate increase and the pool molten state time reduction the backing bead formation on the melt backing improves greatly at the high-speed welding. The energy-saving process of one-sided high-speed welding of the pipes for gas and oil pipelines on the melt backing with the use of glass flux by means of a composite electrode, which provides quality and the welded joints toughness increase, has been developed

  10. Effects of Climate Change on Drinking Water Distribution Network Integrity : Predicting Pipe Failure Resulting from Differential Soil Settlement

    NARCIS (Netherlands)

    Wols, B.A.; Van Daal, K.; Van Thienen, P.

    2014-01-01

    Climate change may result in lowering of ground water levels and consolidation of the soil. The resulting (differential) settlements, associated with soil property transitions, may damage underground pipe infrastructure, such as drinking water distribution sys- tems. The work presented here offers

  11. Effect of sulfate on the transformation of corrosion scale composition and bacterial community in cast iron water distribution pipes

    Science.gov (United States)

    The stability of iron corrosion products and the bacterial composition of biofilm in drinking water distribution systems (DWDS) could have great impact on the water safety at the consumer ends. In this work, pipe loops were setup to investigate the transformation characteristics ...

  12. Characteristics of iron corrosion scales and water quality variations in drinking water distribution systems of different pipe materials.

    Science.gov (United States)

    Li, Manjie; Liu, Zhaowei; Chen, Yongcan; Hai, Yang

    2016-12-01

    Interaction between old, corroded iron pipe surfaces and bulk water is crucial to the water quality protection in drinking water distribution systems (WDS). Iron released from corrosion products will deteriorate water quality and lead to red water. This study attempted to understand the effects of pipe materials on corrosion scale characteristics and water quality variations in WDS. A more than 20-year-old hybrid pipe section assembled of unlined cast iron pipe (UCIP) and galvanized iron pipe (GIP) was selected to investigate physico-chemical characteristics of corrosion scales and their effects on water quality variations. Scanning Electron Microscope (SEM), Energy Dispersive X-ray Spectroscopy (EDS), Inductively Coupled Plasma (ICP) and X-ray Diffraction (XRD) were used to analyze micromorphology and chemical composition of corrosion scales. In bench testing, water quality parameters, such as pH, dissolved oxygen (DO), oxidation reduction potential (ORP), alkalinity, conductivity, turbidity, color, Fe 2+ , Fe 3+ and Zn 2+ , were determined. Scale analysis and bench-scale testing results demonstrated a significant effect of pipe materials on scale characteristics and thereby water quality variations in WDS. Characteristics of corrosion scales sampled from different pipe segments show obvious differences, both in physical and chemical aspects. Corrosion scales were found highly amorphous. Thanks to the protection of zinc coatings, GIP system was identified as the best water quality stability, in spite of high zinc release potential. It is deduced that the complicated composition of corrosion scales and structural break by the weld result in the diminished water quality stability in HP system. Measurement results showed that iron is released mainly in ferric particulate form. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Distribution of radioactive isotopes in rock and ore of Arkhangelskaya pipe from the Arkhangelsk diamond province

    Science.gov (United States)

    Kiselev, G. P.; Yakovlev, E. Yu.; Druzhinin, S. V.; Galkin, A. S.

    2017-09-01

    The contents of radioactive elements and the uranium isotopic composition of kimberlite in the Arkhangelskaya pipe at the M.V. Lomonosov deposit and of nearby country rocks have been studied. A surplus of 234U isotope has been established in rocks from the near-pipe space. The high γ = 234U/238U ratio is controlled by the geological structure of the near-pipe space. A nonequilibrium uranium halo reaches two pipe diameters in size and can be regarded as a local ore guide for kimberlite discovery. The rocks in the nearpipe space are also characterized by elevated or anomalous U, Th, and K contents with respect to the background.

  14. Public health and pipe breaks in water distribution systems: analysis with internet search volume as a proxy.

    Science.gov (United States)

    Shortridge, Julie E; Guikema, Seth D

    2014-04-15

    Drinking water distribution infrastructure has been identified as a factor in waterborne disease outbreaks and improved understanding of the public health risks associated with distribution system failures has been identified as a priority area for research. Pipe breaks may pose a risk, as their occurrence and repair can result in low or negative pressure, potentially allowing contamination of drinking water from adjacent soils. However, measuring this phenomenon is challenging because the most likely health impact is mild gastrointestinal (GI) illness, which is unlikely to result in a doctor or hospital visit. Here we present a novel method that uses data mining techniques and internet search volume to assess the relationship between pipe breaks and symptoms of GI illness in two U.S. cities. Weekly search volume for the terms diarrhea and vomiting was used as the response variable with the number of pipe breaks in each city as a covariate as well as additional covariates to control for seasonal patterns, search volume persistence, and other sources of GI illness. The fit and predictive accuracy of multiple regression and data mining techniques were compared, with the best performance obtained using random forest and bagged regression tree models. Pipe breaks were found to be an important and positively correlated predictor of internet search volume in multiple models in both cities, supporting previous investigations that indicated an increased risk of GI illness from distribution system disturbances. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Numerical Monitoring of Natural Gas Distribution Discrepancy Using CFD Simulator

    OpenAIRE

    Seleznev, Vadim E.

    2010-01-01

    The paper describes a new method for numerical monitoring of discrepancies in natural gas supply to consumers, who receive gas from gas distribution loops. This method serves to resolve the vital problem of commercial natural gas accounting under the conditions of deficient field measurements of gas supply volumes. Numerical monitoring makes it possible to obtain computational estimates of actual gas deliveries over given time spans and to estimate their difference from corresponding values r...

  16. Flooding characteristics of gas-liquid two-phase flow in a horizontal U bend pipe

    Energy Technology Data Exchange (ETDEWEB)

    Sakaguchi, T.; Hosokawa, S.; Fujii, Y. [Kobe Univ. (Japan)] [and others

    1995-09-01

    For next-generation nuclear reactors, hybrid safety systems which consist of active and passive safety systems have been planned. Steam generators with horizontal U bend pipelines will be used as one of the passive safety systems. It is required to clarify flow characteristics, especially the onset of flooding, in the horizontal U bend pipelines in order to examine their safety. Flooding in vertical pipes has been studied extensively. However, there is little study on flooding in the horizontal U bend pipelines. It is supposed that the onset of flooding in the horizontal U bend pipelines is different from that in vertical pipes. On the other hand, liquid is generated due to condensation of steam in pipes of the horizontal steam generators at the loss of coolant accident because the steam generators will be used as a condenser of a cooling system of steam from the reactor. It is necessary to simulate this situation by the supply of water at the middle of horizontal pipe. In the present paper, experiments were carried out using a horizontal U bend pipeline with a liquid supply section in the midway of pipeline. The onset of flooding in the horizontal U bend pipeline was measured. Effects of the length of horizontal pipe and the radius of U bend on the onset of flooding were discussed.

  17. Flooding characteristics of gas-liquid two-phase flow in a horizontal U bend pipe

    International Nuclear Information System (INIS)

    Sakaguchi, T.; Hosokawa, S.; Fujii, Y.

    1995-01-01

    For next-generation nuclear reactors, hybrid safety systems which consist of active and passive safety systems have been planned. Steam generators with horizontal U bend pipelines will be used as one of the passive safety systems. It is required to clarify flow characteristics, especially the onset of flooding, in the horizontal U bend pipelines in order to examine their safety. Flooding in vertical pipes has been studied extensively. However, there is little study on flooding in the horizontal U bend pipelines. It is supposed that the onset of flooding in the horizontal U bend pipelines is different from that in vertical pipes. On the other hand, liquid is generated due to condensation of steam in pipes of the horizontal steam generators at the loss of coolant accident because the steam generators will be used as a condenser of a cooling system of steam from the reactor. It is necessary to simulate this situation by the supply of water at the middle of horizontal pipe. In the present paper, experiments were carried out using a horizontal U bend pipeline with a liquid supply section in the midway of pipeline. The onset of flooding in the horizontal U bend pipeline was measured. Effects of the length of horizontal pipe and the radius of U bend on the onset of flooding were discussed

  18. Failures Analysis of E-Glass Fibre reinforced pipes in Oil and Gas Industry: A Review

    Science.gov (United States)

    Bobba, Sujith; Leman, Z.; Zainuddin, E. S.; Sapuan, S. M.

    2017-07-01

    A comprehensive review is conducted on the failures in the field of manufacturing and installation of E-glass fiber reinforced pipes (GFRP). Some of the failures which are mainly encountered after the installation of E-Glass fiber reinforced pipes are the for nation of air bubbles in between the polyester resin layer and the surface film, dispersion of moisture in between the tubing outer and inner layers after installation, heat released in between the layers of E-glass fiber reinforced pipes due to exothermic reaction which in turn results in the formation of cracks on the surface of the pipe. The recent findings and challenges performed in conducting research regarding the deterioration caused in glass fiber reinforced pipes are highlighted and each type of failure that was identified was illustrated with an appropriate high resolution photograph. Performing creep resistance and fatigue analysis are new aspects which are still requited to be analyzed which ave not been stated in the literature which are nominated.

  19. Characteristics and distribution of soil piping erosion in loess-derived soils of Belgium

    International Nuclear Information System (INIS)

    Verachtert, E.; Van Den Eeckhaut, M.; Poesen, J.; Deckers, J.

    2009-01-01

    Subsurface erosion (piping, tunnel erosion) in non-karstic landscapes has been considered of little importance compared to sheet and gully erosion for a long time. Although the basic factors responsible for piping in certain environments are well understood, there is still uncertainty about the topographic and soil properties inducing subsurface pipe development in loess-derived soils under temperate climate. Therefore, this research aims at understanding the factors controlling the occurrence of piping erosion in the loess-derived soils of the Flemish Ardennes (Belgium). Analysis of ortho photos as well as field surveys were conducted to detect the sites with piping in the study area. Enquiries among farmers and technical services were carried out. In total, 114 sites (parcels) with 301 collapsed soil pipes were found in a 170 kM 2 study area. For each site with piping, data was collected on possible controlling factors: topographic parameters, land use, lithology and soil type. Land use plays an important role as 94% of the sites with piping are found under pasture. (Author) 15 refs.

  20. Characteristics and distribution of soil piping erosion in loess-derived soils of Belgium

    Energy Technology Data Exchange (ETDEWEB)

    Verachtert, E.; Van Den Eeckhaut, M.; Poesen, J.; Deckers, J.

    2009-07-01

    Subsurface erosion (piping, tunnel erosion) in non-karstic landscapes has been considered of little importance compared to sheet and gully erosion for a long time. Although the basic factors responsible for piping in certain environments are well understood, there is still uncertainty about the topographic and soil properties inducing subsurface pipe development in loess-derived soils under temperate climate. Therefore, this research aims at understanding the factors controlling the occurrence of piping erosion in the loess-derived soils of the Flemish Ardennes (Belgium). Analysis of ortho photos as well as field surveys were conducted to detect the sites with piping in the study area. Enquiries among farmers and technical services were carried out. In total, 114 sites (parcels) with 301 collapsed soil pipes were found in a 170 kM{sup 2} study area. For each site with piping, data was collected on possible controlling factors: topographic parameters, land use, lithology and soil type. Land use plays an important role as 94% of the sites with piping are found under pasture. (Author) 15 refs.

  1. Monitoring the mass of UF6 gas and uranium deposits in aluminium pipes using X-ray fluorescence and X-ray transmission gauges

    International Nuclear Information System (INIS)

    Packer, T.W.; Smith, S.M.

    1984-12-01

    In order to determine the enrichment of UF 6 gas in centrifuge plant pipework it is necessary to measure the mass of the gas (pressure) and the mass per unit area of any uranium deposited on the pipe. This paper shows that it is possible to determine the pressure of the UF 6 gas in pipes 120 mm in diameter using an energy-dispersive X-ray fluorescence spectrometer. Results are also given of transmission measurements made using a low power X-ray generator operated at two different applied voltages. A method of using the two measurements to determine the mass per unit area of deposited uranium is described. (author)

  2. CFD Modeling of Gas-Liquid Bubbly Flow in Horizontal Pipes: Influence of Bubble Coalescence and Breakup

    Directory of Open Access Journals (Sweden)

    K. Ekambara

    2012-01-01

    Full Text Available Modelling of gas-liquid bubbly flows is achieved by coupling a population balance equation with the three-dimensional, two-fluid, hydrodynamic model. For gas-liquid bubbly flows, an average bubble number density transport equation has been incorporated in the CFD code CFX 5.7 to describe the temporal and spatial evolution of the gas bubbles population. The coalescence and breakage effects of the gas bubbles are modeled. The coalescence by the random collision driven by turbulence and wake entrainment is considered, while for bubble breakage, the impact of turbulent eddies is considered. Local spatial variations of the gas volume fraction, interfacial area concentration, Sauter mean bubble diameter, and liquid velocity are compared against experimental data in a horizontal pipe, covering a range of gas (0.25 to 1.34 m/s and liquid (3.74 to 5.1 m/s superficial velocities and average volume fractions (4% to 21%. The predicted local variations are in good agreement with the experimental measurements reported in the literature. Furthermore, the development of the flow pattern was examined at three different axial locations of L/D = 25, 148, and 253. The first location is close to the entrance region where the flow is still developing, while the second and the third represent nearly fully developed bubbly flow patterns.

  3. Biogas in the natural gas distribution network; Biogas til nettet

    Energy Technology Data Exchange (ETDEWEB)

    Kvist Jensen, T.

    2009-05-15

    With the Danish 'Thorsoe Biogas Plant' as reference case, an assessment of the possibility of using the existing natural gas distribution network for distributing biogas was carried out. Technologies for and cost of upgrading biogas to natural gas quality are presented. Furthermore, a socio-economic analysis has been performed, including the Danish financial conditions, the market models, and the role of the natural gas distribution companies.

  4. Characterization of linear interfacial waves in a turbulent gas-liquid pipe flow

    Science.gov (United States)

    Ayati, A. A.; Farias, P. S. C.; Azevedo, L. F. A.; de Paula, I. B.

    2017-06-01

    The evolution of interfacial waves on a stratified flow was investigated experimentally for air-water flow in a horizontal pipe. Waves were introduced in the liquid level of stratified flow near the pipe entrance using an oscillating plate. The mean height of liquid layer and the fluctuations superimposed on this mean level were captured using high speed cameras. Digital image processing techniques were used to detect instantaneous interfaces along the pipe. The driving signal of the oscillating plate was controlled by a D/A board that was synchronized with acquisitions. This enabled to perform phase-locked acquisitions and to use ensemble average procedures. Thereby, it was possible to measure the temporal and spatial evolution of the disturbances introduced in the flow. In addition, phase-locked measurements of the velocity field in the liquid layer were performed using standard planar Particle Image Velocimetry (PIV). The velocity fields were extracted at a fixed streamwise location, whereas the measurements of the liquid level were performed at several locations along the pipe. The assessment of the setup was important for validation of the methodology proposed in this work, since it aimed at providing results for further comparisons with theoretical models and numerical simulations. Therefore, the work focuses on validation and characterization of interfacial waves within the linear regime. Results show that under controlled conditions, the wave development can be well captured and reproduced. In addition, linear waves were observed for liquid level oscillations lower than about 1.5% of the pipe diameter. It was not possible to accurately define an amplitude threshold for the appearance of nonlinear effects because it strongly depended on the wave frequency. According to the experimental findings, longer waves display characteristics similar to linear waves, while short ones exhibit a more complex evolution, even for low amplitudes.

  5. Electrical Conduit Distributes Weld Gas Evenly

    Science.gov (United States)

    Ambrisco, D. P.

    1983-01-01

    Purge-gas distributor, made from flexible electrical conduit by drilling small holes along its length, provides even gas flow for welding. Flexible conduit adjusts to accomodate almost any shape and is used for gas coverage in other applications that previously needed formed and drilled solid tubing.

  6. Distribution forms for biogas and natural gas in Sweden

    International Nuclear Information System (INIS)

    Benjaminsson, Johan; Nilsson, Ronny

    2009-11-01

    Since biogas and natural gas basically have the same characteristics, they can be distributed in the same system. In the parts of the country where there is an extensive natural gas distribution network, the infrastructure for natural gas can be used for distribution of biogas. In order to increase the use of renewable energy, it is a political ambition to increase the share of biogas in the natural gas network, and, in the long run, entirely replace natural gas with biogas. Much of biogas production in the country is, however, not reached by the existing natural gas network, and this is also the case for a large part of the potential for future biogas production. In these areas the gas is transported in more or less extensive local gas distribution networks and by truck in compressed or liquid form. Transport of compressed and liquefied gas is efficient in some cases and development of these systems is an ongoing process. A number of facilities are planned for production of large quantities of biogas, several hundred GWh/year, through digestion and gasification processes. These plants will be located either in conjunction with major gas consumers or in the vicinity of the existing natural gas grid. The potential for biogas production is, however, present throughout the country and in order to meet market demand biogas requires efficient distribution systems

  7. New gas distribution system for the ATLAS RPCs

    OpenAIRE

    Pastori, E; Aielli, G

    2013-01-01

    A new gas distribution system for the ATLAS RPCs aimed at equalizing the flow with respect to the average counting rate per gas volume. The system takes into account the expected luminosity foreseen in superLHC (sLHC) and the consequent increase of gas flow necessary for the proper operation.

  8. Distribution, formation and regulation of gas vesicles.

    Science.gov (United States)

    Pfeifer, Felicitas

    2012-10-01

    A range of bacteria and archaea produce intracellular gas-filled proteinaceous structures that function as flotation devices in order to maintain a suitable depth in the aqueous environment. The wall of these gas vesicles is freely permeable to gas molecules and is composed of a small hydrophobic protein, GvpA, which forms a single-layer wall. In addition, several minor structural, accessory or regulatory proteins are required for gas vesicle formation. In different organisms, 8-14 genes encoding gas vesicle proteins have been identified, and their expression has been shown to be regulated by environmental factors. In this Review, I describe the basic properties of gas vesicles, the genes that encode them and how their production is regulated. I also discuss the function of these vesicles and the initial attempts to exploit them for biotechnological purposes.

  9. Impacts of water quality on the corrosion of cast iron pipes for water distribution and proposed source water switch strategy.

    Science.gov (United States)

    Hu, Jun; Dong, Huiyu; Xu, Qiang; Ling, Wencui; Qu, Jiuhui; Qiang, Zhimin

    2018-02-01

    Switch of source water may induce "red water" episodes. This study investigated the impacts of water quality on iron release, dissolved oxygen consumption (ΔDO), corrosion scale evolution and bacterial community succession in cast iron pipes used for drinking water distribution at pilot scale, and proposed a source water switch strategy accordingly. Three sets of old cast iron pipe section (named BP, SP and GP) were excavated on site and assembled in a test base, which had historically transported blended water, surface water and groundwater, respectively. Results indicate that an increasing Cl - or SO 4 2- concentration accelerated iron release, but alkalinity and calcium hardness exhibited an opposite tendency. Disinfectant shift from free chlorine to monochloramine slightly inhibited iron release, while the impact of peroxymonosulfate depended on the source water historically transported in the test pipes. The ΔDO was highly consistent with iron release in all three pipe systems. The mass ratio of magnetite to goethite in the corrosion scales of SP was higher than those of BP and GP and kept almost unchanged over the whole operation period. Siderite and calcite formation confirmed that an increasing alkalinity and hardness inhibited iron release. Iron-reducing bacteria decreased in the BP but increased in the SP and GP; meanwhile, sulfur-oxidizing, sulfate-reducing and iron oxidizing bacteria increased in all three pipe systems. To avoid the occurrence of "red water", a source water switch strategy was proposed based on the difference between local and foreign water qualities. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Development of intelligent pipe locator

    Science.gov (United States)

    Miyamoto, Y.; Wasa, Y.

    1986-08-01

    An inductive pipe locator was developed, so that the position and depth of an underground gas pipe can be accurately located by passing an ac current to the pipe and measuring the generated magnetic field. An ac current (several to 100 kHz) of several tens of mA is transmitted to the underground pipe, and a magnetic sensor above the ground catches the induced magnetic field to estimate the position and depth of the pipe.

  11. On Pair-Particle Distribution in Imperfect Bose Gas

    OpenAIRE

    Shanenko, A. A.

    1996-01-01

    A simple model of estimating the radial distribution function of an imperfect Bose gas in the ground state is presented. The model is based on integro-differential equations derived by considering the space boson distribution in an external field. With the approach proposed, the particular case of dilute Bose gas is investigated within the hard sphere approximation and beyond.

  12. Enabling lean design of biomethane gas distribution grids

    NARCIS (Netherlands)

    Weidenaar, Teade; Jauregui Becker, Juan Manuel; Hoekstra, Sipke

    2015-01-01

    The Dutch gas distribution infrastructure faces several significant changes in the near future. One of the major changes is the production and injection of biomethane into the gas distribution grid. This article introduces a Design Synthesis Tool (DST) that automatically generates biomethane supply

  13. Solutions to operate transmission and distribution gas networks

    Directory of Open Access Journals (Sweden)

    Neacsu Sorin

    2017-01-01

    Full Text Available In order to respect the actual and future regulations, besides SCADA, there is a need for further modern operating solutions for the transmission and distribution gas network. The paper presents the newest operating principles and modern software solutions that represent a considerable help to operate the transmission and distribution gas networks.

  14. Network design for cylinder gas distribution

    Directory of Open Access Journals (Sweden)

    Tejinder Pal Singh

    2015-01-01

    Full Text Available Purpose: Network design of the supply chain is an important and strategic aspect of logistics management. In this paper, we address the network design problem specific to packaged gases (cylinder supply chain. We propose an integrated framework that allows for the determination of the optimal facility locations, the filling plant production capacities, the inventory at plants and hubs, and the number of packages to be routed in primary and secondary transportation. Design/methodology/approach: We formulate the problem as a mixed integer program and then develop a decomposition approach to solve it. We illustrate the proposed framework with numerical examples from real-life packaged gases supply chain. The results show that the decomposition approach is effective in solving a broad range of problem sizes. Findings: The main finding of this paper is that decomposing the network design problem into two sub-problems is very effective to tackle the real-life large scale network design problems occurring in cylinder gas distribution by optimizing strategic and tactical decisions and approximating the operational decisions. We also benchmark the results from the decomposition approach by solving the complete packaged gases network design model for smaller test cases. Originality/value: The main contribution of our work is that it integrates supply chain network design decisions without fixing the fillings plant locations with inventory and resource allocation decisions required at the plants. We also consider the transportation costs for the entire supply chain including the transhipment costs among different facilities by deciding the replenishment frequency.

  15. Technical description of the Swedish natural gas distribution system

    Energy Technology Data Exchange (ETDEWEB)

    Nilsson, Ronny [KM Miljoeteknik AB (Sweden)

    1997-06-01

    This description of the Swedish distribution network has been produced to provide information for distribution companies, trade organisations, etc., who have an interest in getting a clear understanding of the technical design and standards, technical directives, etc., which have served as guidance in the development. The technical description covers the piping system from a measuring and regulating station (MR station) up to the consumer`s substation, however, only sections with a maximum operating pressure of 4 bar. By way of introduction, the description contains introductory information on supply channels, consumption patterns and the principal design of the high pressure network in Sweden 10 refs, 10 figs, 1 tab

  16. In-Line Acoustic Device Inspection of Leakage in Water Distribution Pipes Based on Wavelet and Neural Network

    Directory of Open Access Journals (Sweden)

    Dileep Kumar

    2017-01-01

    Full Text Available Traditionally permanent acoustic sensors leak detection techniques have been proven to be very effective in water distribution pipes. However, these methods need long distance deployment and proper position of sensors and cannot be implemented on underground pipelines. An inline-inspection acoustic device is developed which consists of acoustic sensors. The device will travel by the flow of water through the pipes which record all noise events and detect small leaks. However, it records all the noise events regarding background noises, but the time domain noisy acoustic signal cannot manifest complete features such as the leak flow rate which does not distinguish the leak signal and environmental disturbance. This paper presents an algorithm structure with the modularity of wavelet and neural network, which combines the capability of wavelet transform analyzing leakage signals and classification capability of artificial neural networks. This study validates that the time domain is not evident to the complete features regarding noisy leak signals and significance of selection of mother wavelet to extract the noise event features in water distribution pipes. The simulation consequences have shown that an appropriate mother wavelet has been selected and localized to extract the features of the signal with leak noise and background noise, and by neural network implementation, the method improves the classification performance of extracted features.

  17. Do estrogenic compounds in drinking water migrating from plastic pipe distribution system pose adverse effects to human? An analysis of scientific literature.

    Science.gov (United States)

    Liu, Ze-Hua; Yin, Hua; Dang, Zhi

    2017-01-01

    With the widespread application of plastic pipes in drinking water distribution system, the effects of various leachable organic chemicals have been investigated and their occurrence in drinking water supplies is monitored. Most studies focus on the odor problems these substances may cause. This study investigates the potential endocrine disrupting effects of the migrating compound 2,4-di-tert-butylphenol (2,4-d-t-BP). The summarized results show that the migration of 2,4-d-t-BP from plastic pipes could result in chronic exposure and the migration levels varied greatly among different plastic pipe materials and manufacturing brands. Based on estrogen equivalent (EEQ), the migrating levels of the leachable compound 2,4-d-t-BP in most plastic pipes were relative low. However, the EEQ levels in drinking water migrating from four out of 15 pipes may pose significant adverse effects. With the increasingly strict requirements on regulation of drinking water quality, these results indicate that some drinking water transported with plastic pipes may not be safe for human consumption due to the occurrence of 2,4-d-t-BP. Moreover, 2,4-d-t-BP is not the only plastic pipe-migrating estrogenic compound, other compounds such as 2-tert-butylphenol (2-t-BP), 4-tert-butylphenol (4-t-BP), and others may also be leachable from plastic pipes.

  18. By-pass flows and temperature distribution in a hot gas duct internally insulated by carbon stone

    International Nuclear Information System (INIS)

    Konuk, A.A.

    1979-01-01

    A mathematical model has been developed to calculate by-pass flows and temperature distribution in a hot gas duct internally insulated by carbon stone rings. The equations of conservation of mass and momentum are solved for a piping system to obtain axial and radial by-pass velocities. The energy equation is solved next by a marching method to obtain the radial temperature distribution along the duct. The results, although qualitative due to simplifications in the model, are useful to study the effects of duct geometry on its performance. (Author) [pt

  19. [Effect of the change in sulphate and dissolved oxygen mass concentration on metal release in old cast iron distribution pipes].

    Science.gov (United States)

    Wu, Yong-li; Shi, Bao-you; Sun, Hui-fang; Zhang, Zhi-huan; Gu, Jun-nong; Wang, Dong-sheng

    2013-09-01

    To understand the processes of corrosion by-product release and the consequent "red water" problems caused by the variation of water chemical composition in drinking water distribution system, the effect of sulphate and dissolved oxygen (DO) concentration on total iron release in corroded old iron pipe sections historically transporting groundwater was investigated in laboratory using small-scale pipe section reactors. The release behaviors of some low-level metals, such as Mn, As, Cr, Cu, Zn and Ni, in the process of iron release were also monitored. The results showed that the total iron and Mn release increased significantly with the increase of sulphate concentration, and apparent red water occurred when sulphate concentration was above 400 mg x L(-1). With the increase of sulfate concentration, the effluent concentrations of As, Cr, Cu, Zn and Ni also increased obviously, however, the effluent concentrations of these metals were lower than the influent concentrations under most circumstances, which indicated that adsorption of these metals by pipe corrosion scales occurred. Increasing DO within a certain range could significantly inhibit the iron release.

  20. Pyrosequencing analysis of source water switch and sulfate-induced bacterial community transformation in simulated drinking water distribution pipes.

    Science.gov (United States)

    Yang, Fan; Shi, Baoyou; Zhang, Weiyu; Cui, Jing; Guo, Jianbo; Wang, Dongsheng; Wu, Nan; Liu, Xinyuan

    2017-12-01

    Inter-basin water transfer and source water switching will be increasingly launched due to significant population increase and the shortage of the local water resources in cities around the world. Source water switch may cause physiochemical and microbiological de-stabilization of pipe material, biofilms, and loose deposits in drinking water distribution system (DWDS). Great sulfate alteration during source water switch had been deemed as the main cause of a red water case that occurred in a northern China city. To ascertain the relationship between water quality changing and bacterial communities of biofilms in DWDS and possible bacteria risk in a red water case, water quality changing experiments in simulated DWDSs were conducted for approximately 2 years. Twenty-five corrosion scale samples and eight water samples collected from pipe harvest sites or during experimental periods were analyzed for their bacterial community composition by 454-pyrosequencing technology. Taxonomy results together with redundancy analysis (RDA) or canonical correspondence analysis (CCA) and hierarchical cluster analysis all indicated that bacterial community of samples with groundwater (GW) or surface water (SW) supply history and their variations under high sulfate water were rather different owing to different water source histories and the original pipe scale characteristics. Potential opportunistic pathogens: Burkholderia, Escherichia-Shigella, Mycobacterium, Serratia, Ralstonia, Novosphingobium, Flavobacterium, Sphingomonas, and Sphingopyxis were observed in scale or water samples.

  1. Numerical investigation on residual stress distribution and evolution during multipass narrow gap welding of thick-walled stainless steel pipes

    International Nuclear Information System (INIS)

    Liu, C.; Zhang, J.X.; Xue, C.B.

    2011-01-01

    Research highlights: → We performed pass-by-pass simulation of stresses for welding of thick-walled pipes. → The distributions and evolution of the residual stresses are demonstrated. → After the groove is filled to a height, the through-wall stress is almost unchanged. - Abstracts: The detailed pass-by-pass finite element (FE) simulation is presented to investigate the residual stresses in narrow gap multipass welding of pipes with a wall thickness of 70 mm and 73 weld passes. The simulated residual stress on the outer surface is validated with the experimental one. The distribution and evolution of the through-wall residual stresses are demonstrated. The investigated results show that the residual stresses on the outer and inner surfaces are tensile in the weld zone and its vicinity. The through-wall axial residual stresses at the weld center line and the HAZ line demonstrate a distribution of bending type. The through-wall hoop residual stress within the weld is mostly tensile. After the groove is filled to a certain height, the peak tensile stresses and the stress distribution patterns for both axial and hoop stresses remain almost unchanged.

  2. 46 CFR 153.294 - Marking of piping systems.

    Science.gov (United States)

    2010-10-01

    ... CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Piping Systems and Cargo Handling Equipment § 153.294 Marking of piping systems. (a) Each cargo piping system...

  3. 46 CFR 153.281 - Piping to independent tanks.

    Science.gov (United States)

    2010-10-01

    ... CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Piping Systems and Cargo Handling Equipment § 153.281 Piping to independent tanks. Piping for an independent...

  4. Extensive optimisation analyses of the piping of two large underground gas storage ariel compressors

    NARCIS (Netherlands)

    Eijk, A.; Korst, H.J.C.; Ploumen, G.; Heyer, D.

    2007-01-01

    Two large identical 6-cylinder Ariel JGB/6 compressors of each 7.5 Mw, are used for the underground gas storage (UGS) plant of Essent in Epe, Germany. The compressors can be operated at a wide range of operating conditions, e.g. variable suction and discharge pressures, 2-stage mode during gas

  5. A numerical model for pressure drop and flow distribution in a solar collector with U-connected absorber pipes

    DEFF Research Database (Denmark)

    Bava, Federico; Furbo, Simon

    2016-01-01

    This study presents a numerical model calculating the pressure drop and flow distribution in a solar collector with U-type harp configuration in isothermal conditions. The flow maldistribution in the absorber pipes, caused by the different hydraulic resistances, was considered to evaluate...... the pressure drop across the collector. The model was developed in Matlab and is based on correlations found in literature for both friction losses and local losses, and was compared in terms of overall pressure drop against experimental measurements carried out on an Arcon Sunmark HT 35/10 solar collector...

  6. Land based use of natural gas - distribution solutions

    International Nuclear Information System (INIS)

    Jordanger, Einar; Moelnvik, Mona J.; Owren, Geir; Einang, Per Magne; Grinden, Bjoern; Tangen, Grethe

    2002-05-01

    The report presents results from the project ''Landbasert bruk av naturgass - distribusjonsloesninger'' (Land based use of natural gas - distribution solutions). It describes the aims of the project, the political external conditions for the use of natural gas, some environmental profits by changing from petroleum and coal to natural gas, the Norwegian infrastructure, the optimisation of energy transport, strategic consequences of the introduction of LNG and the practical consequences of the Enova strategy

  7. Transients in pipes

    International Nuclear Information System (INIS)

    Marchesin, D.; Paes-Leme, P.J.S.; Sampaio, R.

    1981-01-01

    The motion of a fluid in a pipe is commonly modeled utilizing the one space dimension conservation laws of mass and momentum. The development of shocks and spikes utilizing the uniform sampling method is studied. The effects of temperature variations and friction are compared for gas pipes. (Author) [pt

  8. The anatomy of a pipe bomb explosion: measuring the mass and velocity distributions of container fragments.

    Science.gov (United States)

    Bors, Dana; Cummins, Josh; Goodpaster, John

    2014-01-01

    Improvised explosive devices such as pipe bombs are prevalent due to the availability of materials and ease of construction. However, little is known about how these devices actually explode, as few attempts to characterize fragmentation patterns have been attempted. In this study, seven devices composed of various pipe materials (PVC, black steel, and galvanized steel) and two energetic fillers (Pyrodex and Alliant Red Dot) were initiated and the explosions captured using high-speed videography. The video footage was used to calculate fragment velocities, which were represented as particle velocity vector maps. In addition, the fragments were weighed. The results demonstrate a correlation between the type of energetic filler and both the size and velocity of the fragments. Larger fragments were produced by Pyrodex filler indicating a less complete fragmentation, compared with smaller fragments produced by double-base smokeless powder. Additionally, higher fragment velocities were seen with Alliant Red Dot filler. © 2013 American Academy of Forensic Sciences.

  9. Natural gas distribution network of Lima and Callao, Peru

    Energy Technology Data Exchange (ETDEWEB)

    Maroye, Stephane; Aerssens, Andre [Tractebel Engineering, Lima (Peru)

    2005-07-01

    In May 2002, Suez-Tractebel was awarded by the government of Peru a 30-year concession for the construction and operation of the gas distribution network in Lima, Peru. On 10 July, 2004, first gas was delivered to Lima, 1 month ahead of the official date. This gas distribution network, operated by GNLC (Gas Natural de Lima y Callao), delivers gas to some of the largest industries and power generators in and around Lima and the harbour area of Callao. Gas delivered in Lima comes through a 700 km HP gas pipeline from Camisea fields. This pipeline is operated by TGP (Transportadora de Gas del Peru). A City Gate is located at Lurin, on the southern side of the city. The gas distribution network is made of a 62 km main pipeline (20') with 25 km laterals. The main pipeline is operated at 50 bar, as the main customer, the Etevensa power plant, is located on the northern side of the city. Due to this high operating pressure combined to the surroundings, specific design philosophies were adopted to meet the extreme safety requirements. This paper highlights the specific measures taken during construction phase and the experience of the first months of operation of this challenging project. (author)

  10. Influence of physical aging on impact embrittlement of uPVC pipes

    NARCIS (Netherlands)

    Visser, Roy; Bor, Teunis Cornelis; Wolters, Mannes; Warnet, Laurent; Govaert, L.E.

    2011-01-01

    Most failures of unplasticised poly(vinyl chloride) (uPVC) pipes used in the Dutch gas distribution network originate from third party damage. Brittle pipes should therefore be replaced to ensure safe operation of the network. In this study, the relation between physical aging and embrittlement of

  11. System analysis and planning of a gas distribution network

    Energy Technology Data Exchange (ETDEWEB)

    Salas, Edwin F.M.; Farias, Helio Monteiro [AUTOMIND, Rio de Janeiro, RJ (Brazil); Costa, Carla V.R. [Universidade Salvador (UNIFACS), BA (Brazil)

    2009-07-01

    The increase in demand by gas consumers require that projects or improvements in gas distribution networks be made carefully and safely to ensure a continuous, efficient and economical supply. Gas distribution companies must ensure that the networks and equipment involved are defined and designed at the appropriate time to attend to the demands of the market. To do that a gas distribution network analysis and planning tool should use distribution networks and transmission models for the current situation and the future changes to be implemented. These models are used to evaluate project options and help in making appropriate decisions in order to minimize the capital investment in new components or simple changes in operational procedures. Gas demands are increasing and it is important that gas distribute design new distribution systems to ensure this growth, considering financial constraints of the company, as well as local legislation and regulation. In this study some steps of developing a flexible system that attends to those needs will be described. The analysis of distribution requires geographically referenced data for the models as well as an accurate connectivity and the attributes of the equipment. GIS systems are often used as a deposit center that holds the majority of this information. GIS systems are constantly updated as distribution network equipment is modified. The distribution network modeling gathered from this system ensures that the model represents the current network condition. The benefits of this architecture drastically reduce the creation and maintenance cost of the network models, because network components data are conveniently made available to populate the distribution network. This architecture ensures that the models are continually reflecting the reality of the distribution network. (author)

  12. N2 gas station and gas distribution system for TLD personnel monitoring gas based semi-automatic badge readers

    International Nuclear Information System (INIS)

    Chourasiya, G.; Pradhan, S.M.; Kher, R.K.; Bhatt, B.C

    2003-01-01

    Full text: New improvised hot gas based Auto TLD badge reader has several advantages over the earlier contact heating based manual badge reader. It requires constant supply of N 2 gas for its operation; The gas supplied using replaceable individual gas cylinders may have some safety hazards in their handling. It was therefore considered worthwhile to setup a N 2 gas assembly/ station outside the lab area and to bring regulated gas supply through network of tubes with proper regulation to the individual readers. The paper presents detailed description of the gas station and distribution system. The system is quite useful and offers several practical advantages for readout of TLD badges on the semiautomatic badge readers based on gas heating. Important advantage from dosimetric point of view is avoidance of gas flow rate fluctuations and corresponding variations in TL readouts

  13. The consequences of liberalisation of the gas market. Part 3. Natural gas distribution managers

    International Nuclear Information System (INIS)

    Van Gelder, J.W.

    1999-01-01

    In a deregulated gas market network, operation will become an independent business, that can even be used to make profit. In this part of the series on the liberalization of the natural gas market attention is paid to network operators. There appear not to be any changes for the operators of large offshore transmission pipelines. However, there will be some impact on the transmission system of Gasunie (Dutch natural gas trading company). According to the new Dutch Natural Gas Bill Gasunie has to publish separate accounts of its transmission activities. For energy distribution companies a legal separation of network activities is not compulsory. Natural gas network operators have to develop a number of new duties. A new information distribution system is required to quickly match supply and demand. Also, distribution companies have to set distribution tariffs. But the biggest change for network operators is that network operation and maintenance are no longer exclusively aimed at operational reliability and safety, but also at profitability

  14. Monitoring and localization of buried plastic natural gas pipes using passive RF tags

    Science.gov (United States)

    Mondal, Saikat; Kumar, Deepak; Ghazali, Mohd. Ifwat; Chahal, Prem; Udpa, Lalita; Deng, Yiming

    2018-04-01

    A passive harmonic radio frequency (RF) tag on the pipe with added sensing capabilities is proposed in this paper. Radio frequency identification (RFID) based tagging has already emerged as a potential solution for chemical sensing, location detection, animal tagging, etc. Harmonic transponders are already quite popular compared to conventional RFIDs due to their improved signal to noise ratio (SNR). However, the operating frequency, transmitted power and tag efficiency become critical issues for underground RFIDs. In this paper, a comprehensive on-tag sensing, power budget and frequency analyses is performed for buried harmonic tag design. Accurate tracking of infrastructure burial depth is proposed to reduce the probability of failure of underground pipelines. Burial depth is estimated using phase information of received signals at different frequencies calculated using genetic algorithm (GA) based optimization for post processing. Suitable frequency range is determined for a variety of soil with different moisture content for small tag-antenna size. Different types of harmonic tags such as 1) Schottky diode, 2) Non-linear Transmission Line (NLTL) were compared for underground applications. In this study, the power, frequency and tag design have been optimized to achieve small antenna size, minimum signal loss and simple reader circuit for underground detection at up to 5 feet depth in different soil medium and moisture contents.

  15. Residual stress distribution in austenitic stainless steel pipe butt-welded joint measured by neutron diffraction technique

    International Nuclear Information System (INIS)

    Maekawa, Akira; Noda, Michiyasu; Oumaya, Toru; Takahashi, Shigeru

    2009-01-01

    Residual stress is inevitable consequence of welding or manufacturing process, which might greatly affect propagation of high-cycle fatigue or SCC crack. In order to evaluate damages due to the crack, it is required to estimate residual stress and to reflect them to the evaluation process as well. The magnitude and distribution of residual stress greatly depend on the individual process of welding or manufacturing, while the accuracy of prediction or measurement is still insufficient. This paper reports the result of residual stress measurement of butt-welded pipe made of austenitic stainless steel. It also intended to improve prediction and measurement techniques concerning to residual stress. The measurement was conducted by neutron diffraction technique employing the diffractometer for residual stress analysis developed by Japan Atomic Energy Agency. The measured results showed typical characteristics of butt-welded pipe both in decline of stress along axial direction and in radial distribution of bending due to axial stress. The measured result agreed qualitatively with the result predicted by the finite element analysis. A quantitative comparison between measured result and analysis showed a shift of the measured stress toward higher tensile. The measured result was also compared with the results by X-ray diffraction and strain-gauge methods to grasp the distinctive results of the methods. (author)

  16. Relationships among ventilation-perfusion distribution, multiple inert gas methodology and metabolic blood-gas tensions.

    Science.gov (United States)

    Lee, A S; Patterson, R W; Kaufman, R D

    1987-12-01

    The retention equations upon which the Multiple Inert Gas Method is based are derived from basic principles using elementary algebra. It is shown that widely disparate distributions produce indistinguishable sets of retentions. The limits of resolution of perfused compartments in the VA/Q distribution obtainable by the use of the multiple inert gas method are explored mathematically, and determined to be at most shunt and two alveolar compartments ("tripartite" distribution). Every continuous distribution studied produced retentions indistinguishable from those of its unique "matching" tripartite distribution. When a distribution is minimally specified, it is unique. Any additional specification (increased resolution--more compartments) of the distribution results in the existence of an infinitude of possible distributions characterized by indistinguishable sets of retention values. No further increase in resolution results from the use of more tracers. When sets of retention values were extracted from published multiple inert gas method continuous distributions, and compared with the published "measured" retention sets, substantial differences were found. This illustrates the potential errors incurred in the practical, in vivo application of the multiple inert gas method. In preliminary studies, the tripartite distribution could be determined with at least comparable accuracy by blood-gas (oxygen, carbon dioxide) measurements.

  17. Gas Gun Model and Comparison to Experimental Performance of Pipe Guns Operating with Light Propellant Gases and Large Cryogenic Pellets

    Energy Technology Data Exchange (ETDEWEB)

    Reed, J. R. [University of Tennessee, Knoxville (UTK); Carmichael, J. R. [Fermi National Accelerator Laboratory (FNAL); Gebhart, T. E. [University of Florida, Gainesville; Combs, Stephen Kirk [ORNL; Baylor, Larry R. [ORNL; Rasmussen, David A. [ORNL; Meitner, Steven J. [ORNL; Lyttle, Mark S. [ORNL

    2017-10-01

    Injection of multiple large (~10 to 30 mm diameter) shattered pellets into ITER plasmas is presently part of the scheme planned to mitigate the deleterious effects of disruptions on the vessel components. To help in the design and optimize performance of the pellet injectors for this application, a model referred to as “the gas gun simulator” has been developed and benchmarked against experimental data. The computer code simulator is a Java program that models the gas-dynamics characteristics of a single-stage gas gun. Following a stepwise approach, the code utilizes a variety of input parameters to incrementally simulate and analyze the dynamics of the gun as the projectile is launched down the barrel. Using input data, the model can calculate gun performance based on physical characteristics, such as propellant-gas and fast-valve properties, barrel geometry, and pellet mass. Although the model is fundamentally generic, the present version is configured to accommodate cryogenic pellets composed of H2, D2, Ne, Ar, and mixtures of them and light propellant gases (H2, D2, and He). The pellets are solidified in situ in pipe guns that consist of stainless steel tubes and fast-acting valves that provide the propellant gas for pellet acceleration (to speeds ~200 to 700 m/s). The pellet speed is the key parameter in determining the response time of a shattered pellet system to a plasma disruption event. The calculated speeds from the code simulations of experiments were typically in excellent agreement with the measured values. With the gas gun simulator validated for many test shots and over a wide range of physical and operating parameters, it is a valuable tool for optimization of the injector design, including the fast valve design (orifice size and volume) for any operating pressure (~40 bar expected for the ITER application) and barrel length for any pellet size (mass, diameter, and length). Key design parameters and proposed values for the pellet injectors for

  18. Potential migration of organic pollutants in pipes of polyethylene. Study in pipelines of distribution net of drinkable water; Migracion potential de contaminantes organicos en tubos de polietileno. Estudio en tuberias de red de distribuciond e agua potable

    Energy Technology Data Exchange (ETDEWEB)

    Ballel, X.; Ciurana de, C.; Caixach, J.; Cortina, M.; Om, M.

    2002-07-01

    Polyethylene pipes and connections are being widely used in treated water distribution services. Migration of low molecular weight compounds from the polyethylene into the water can change its final quality. This paper is about the concentrations and identification of the migration compounds found in treated water after staying in contact with low and high-density polyethylene. Identification and quantification were carried out using CLSA (Closed Loop Stripping Analysis) extraction technique and gas chromatography coupled to mass spectrometry (HRGC/HRMS). (Author) 12 refs.

  19. Distribution of neutral gas and dust near Saturn

    Science.gov (United States)

    Sittler, E. C., Jr.; Scudder, J. D.; Bridge, H. S.

    1981-01-01

    The distribution of neutral gas and dust within the magnetosphere of Saturn has been inferred from the electron velocity distribution functions measured by the Voyager 1 plasma science experiment. Substantial enhancements of neutral material near Titan and in the vicinity of Enceladus are found. The E ring is also shown to be larger than previously thought.

  20. Ecoulements intermittents de gaz et de liquide en conduite verticale Intermittent Gas and Liquid Flows in a Vertical Pipe.

    Directory of Open Access Journals (Sweden)

    Line A.

    2006-11-01

    Full Text Available Le modèle présenté ici permet la pré-détermination du gradient de pression, du taux global de gaz, et de grandeurs caractéristiques de l'intermittence, dans un écoulement à poches et bouchons en conduite verticale. L'écriture des lois de conservation en moyenne phasique conditionnelle conduit à la définition d'une cellule moyenne équivalente. La fermeture du modèle est assurée par des lois de contrainte de cisaillement film-paroi, film-poche, bouchon-paroi, par une loi d'arrachage du gaz au culot de la poche, une loi de glissement du gaz dans les bouchons et par une loi de la vitesse moyenne de propagation des fronts de poches. Le calibrage et la qualification du modèle s'appuient sur deux banques de données, dont l'une a été obtenue avec des fluides pétroliers dans des conditions proches des situations industrielles (boucle diphasique de Boussens. The model described here can be used to predetermine the pressure gradient, the overall gas rate and the characteristic intermittence magnitudes in pocket and slug flow in a vertical pipe. The way governing equations in the conditional phase average are written defines an equivalent average cell. The model is closed by film/wall, film/pocket and slug/wall shear-stress laws, by a pulloff law for the gas at the bottom of the pocket, a slippage law for the gas in the slugs, and a mean propagation velocity law for the pocket fronts. The calibration and qualification of the model are based on two data banks, one of which contains data on petroleum fluids under conditions close to industrial situations (two-phase loop at Boussens.

  1. Gas turbine control for islanding operation of distribution systems

    DEFF Research Database (Denmark)

    Mahat, Pukar; Chen, Zhe; Bak-Jensen, Birgitte

    2009-01-01

    Danish distribution systems are characterized by a significant penetration of small gas turbine generators (GTGs) and fixed speed wind turbine generators (WTGs). Island operation of these distribution systems are becoming a viable option for economical and technical reasons. However, stabilizing...... frequency in an islanded system is one of the major challenges. This paper presents three different gas turbine governors for possible operation of distribution systems in an islanding mode. Simulation results are presented to show the performance of these governors in grid connected and islanding mode....

  2. Understanding Passive Layer Formation for Further Corrosion Management in Gas Production Pipes

    Science.gov (United States)

    Santoso, R. K.; Rahmawati, S. D.; Gadesa, A.; Wahyuningrum, D.

    2017-07-01

    Corrosion is a critical issue during the development of a gas field, especially wet gas or retrograde gas field. Corrosion affects the management system of a field and further impacts the amount of investment. Therefore, accurate prediction of corrosion rate is needed to plan an effective preventive action before going further to the development phase. One of the important parameters that should be noticed to create an accurate prediction is the formation of the passive layer. In CO2-H2S environment, there will be three possibilities of passive layer: FeS, FeCO3 or no passive layer. In this study, we create mathematical models to determine the formed passive layer in each segment of the gas production tubing and pipeline. The model is built using Faraday’s Law and Thermodynamic approach to account the passive layer formation at different temperature, pH, corrosion rate and partial pressure of CO2 and H2S. From the simulation, it was found that there were three boundary conditions: no scale-FeS boundary, no scale-FeCO3 boundary and FeS-FeCO3 boundary. The first two boundaries evolved over a time as the concentration of Fe2+ ions was increasing. However, FeS-FeCO3 boundary remained steady as it was not affected by the addition of Fe2+ ions. Using sample case study, few variations were noticed at production pipeline and tubing. It was caused by the gas composition, which contained high CO2 and very low H2S. Boundary conditions only changed slightly over two days period.

  3. Ecoulements diphasiques gaz-liquide à poches et à bouchons en conduites Two-Phase Gas-Liquid Slug Flow in Pipes

    Directory of Open Access Journals (Sweden)

    Ferschneider G.

    2006-11-01

    Full Text Available Les écoulements diphasiques gaz-liquide ont été étudiés afin de contribuer à développer des modèles de calculs prédictifs des pertes de charge dans les conduites de production des bruts pétroliers. Les expériences nécessaires ont été réalisées sur la boucle diphasique de Boussens dans les conditions suivantes représentatives des conditions industrielles : diamètre 6 , longueur 120 m, disposition de la conduite horizontale ou faiblement ascendante, couple de fluide gaz naturel-huile légère. Le gradient de pression, le contenu global, et la distribution locale des phases ont été mesurés. Le traitement des équations de conservation phasique intégrées sur la section par différents types de moyennes a permis de développer un modèle cellulaire qui inclue un nombre limité d'équations constitutives nécessaires à sa fermeture. Ce modèle prédétermine convenablement le gradient de pression, le contenu gaz global et la longueur des poches et des bouchons. Two-phase gas-liquid flows were analyzed so as to develop models for prediction of pressure drops in crude-oil production lines. The experiments were performed on the two-phase loop at Boussens under the following representative industrial conditions: 6 diameter, 120 m length, horizontal or slightly rising pipe, couple of fluids natural gas and light oil. The pressure gradient, average content and local phase distribution were measured. Conservation phase equations integrated along the cross-section were processed by different time-averaged operators so as to develop a cellular model including a limited number of constitutive equations required for its closure. This model suitably predetermines the pressure gradient, the average gas content and the length of gas and liquid slug.

  4. Experimental on two sensors combination used in horizontal pipe gas-water two-phase flow

    International Nuclear Information System (INIS)

    Wu, Hao; Dong, Feng

    2014-01-01

    Gas-water two phase flow phenomenon widely exists in production and living and the measurement of it is meaningful. A new type of long-waist cone flow sensor has been designed to measure two-phase mass flow rate. Six rings structure of conductance probe is used to measure volume fraction and axial velocity. The calibration of them have been made. Two sensors have been combined in horizontal pipeline experiment to measure two-phase flow mass flow rate. Several model of gas-water two-phase flow has been discussed. The calculation errors of total mass flow rate measurement is less than 5% based on the revised homogeneous flow model

  5. Inhomogeneous Oxygen Vacancy Distribution in Semiconductor Gas Sensors: Formation, Migration and Determination on Gas Sensing Characteristics

    OpenAIRE

    Liu, Jianqiao; Gao, Yinglin; Wu, Xu; Jin, Guohua; Zhai, Zhaoxia; Liu, Huan

    2017-01-01

    The density of oxygen vacancies in semiconductor gas sensors was often assumed to be identical throughout the grain in the numerical discussion of the gas-sensing mechanism of the devices. In contrast, the actual devices had grains with inhomogeneous distribution of oxygen vacancy under non-ideal conditions. This conflict between reality and discussion drove us to study the formation and migration of the oxygen defects in semiconductor grains. A model of the gradient-distributed oxygen vacanc...

  6. MORPHOTECTONIC ANALYSIS AT TANIMBAR TRENCH AS A BASE FOR GAS PIPE LAYING BETWEEN MASELA BLOCK AND SELARU ISLAND, MOLUCCAS PROVINCE

    Directory of Open Access Journals (Sweden)

    Ediar Usman

    2017-07-01

    Full Text Available The study area is located at Masela Block and its surrounding, Moluccas Province. Result of the deep sea measurement and global data conversion provide description of three dimensions around the track lines area. This result is overlay with seismic data, that can give morphotectonic implication between Asian and Australian Plates. Track lines of MGI-2010-MSL-1, 2 and 3 show that the profile of the sea floor, form the high morphology which represents the volcanic islands. It forms west – east direction of fold-thrust belt non-volcanic outer Banda arc. The southern part trench of the Australian Continent reflected the platform system and undulation morphology. The sea floor profile ( VE 1:5 show that the slope profile ranges between 0º and 8º. Furthermore, the morphology of the sea floor can be classified as a relatively flat slope. Due to this condition, this area may be used for gas pipe laying along 146 km distance, between the Well of Abadi 1 at the Masela Block and Selaru Island at south Tanimbar Islands.

  7. 75 FR 39680 - Houston Pipe Line Company LP, Worsham-Steed Gas Storage, L.P., Energy Transfer Fuel, LP, Mid...

    Science.gov (United States)

    2010-07-12

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR10-44-000; Docket No. PR10-46-000; Docket No. PR10-48- 000; Docket No. PR10-49-000; Docket No. PR10-50-000] Houston Pipe Line Company LP, Worsham-Steed Gas Storage, L.P., Energy Transfer Fuel, LP, Mid Continent Market Center, L.L.C...

  8. A perspective on cost-effectiveness of greenhouse gas reduction solutions in water distribution systems

    Science.gov (United States)

    Hendrickson, Thomas P.; Horvath, Arpad

    2014-01-01

    Water distribution systems (WDSs) face great challenges as aging infrastructures require significant investments in rehabilitation, replacement, and expansion. Reducing environmental impacts as WDSs develop is essential for utility managers and policy makers. This study quantifies the existing greenhouse gas (GHG) footprint of common WDS elements using life-cycle assessment (LCA) while identifying the greatest opportunities for emission reduction. This study addresses oversights of the related literature, which fails to capture several WDS elements and to provide detailed life-cycle inventories. The life-cycle inventory results for a US case study utility reveal that 81% of GHGs are from pumping energy, where a large portion of these emissions are a result of distribution leaks, which account for 270 billion l of water losses daily in the United States. Pipe replacement scheduling is analyzed from an environmental perspective where, through incorporating leak impacts, a tool reveals that optimal replacement is no more than 20 years, which is in contrast to the US average of 200 years. Carbon abatement costs (CACs) are calculated for different leak reduction scenarios for the case utility that range from -130 to 35 t-1 CO2(eq). Including life-cycle modeling in evaluating pipe materials identified polyvinyl chloride (PVC) and cement-lined ductile iron (DICL) as the Pareto efficient options, however; utilizing PVC presents human health risks. The model developed for the case utility is applied to California and Texas to determine the CACs of reducing leaks to 5% of distributed water. For California, annual GHG savings from reducing leaks alone (3.4 million tons of CO2(eq)) are found to exceed California Air Resources Board’s estimate for energy efficiency improvements in the state’s water infrastructure.

  9. Proposed systematic methodology for analysis of Pb-210 radioactivity in residues produced in Brazilian natural gas pipes

    International Nuclear Information System (INIS)

    Ferreira, Aloisio Cordilha

    2003-11-01

    Since the 80's, the potential radiological hazards due to the handling of solid wastes contaminated with Rn-222 long-lived progeny - Pb-210 in special - produced in gas pipes and removed by pig operations have been subject of growing concern abroad our country. Nevertheless, little or no attention has been paid to this matter in the Brazilian plants up to now, being these hazards frequently underestimated or even ignored. The main purpose of this work was to propose a systematic methodology for analysis of Pb-210 radioactivity in black powder samples from some Brazilian plants, through the evaluation of direct Pb-210 gamma spectrometry and Bi-210 beta counting technical viabilities. In both cases, one in five samples of black powder analysed showed relevant activity (above 1Bq/kg) of Pb-210, being these results probably related to particular features of each specific plant (production levels, reservoir geochemical profile, etc.), in such a way that a single pattern is not observed. For the proposed methodology, gamma spectrometry proved to be the most reliable technique, showing a 3.5% standard deviation, and, for a 95% confidence level, overall fitness in the range of Pb-210 concentration of activity presented in the standard sample reference sheet, provided by IAEA for intercomparison purposes. In the Brazilian scene, however, the availability of statistically supported evidences is insufficient to allow the potential radiological hazard due to the management of black powder to be discarded. Thus, further research efforts are recommended in order to detect the eventually critical regions or plants where gas exploration, production and processing practices will require a regular program of radiological surveillance, in the near future. (author)

  10. On the equilibrium distribution of gas in clusters of galaxies

    Science.gov (United States)

    Lea, S. M.

    1975-01-01

    The hydrostatic-equilibrium solution for a polytropic gas in a cluster of galaxies has been calculated. The gas has a wider distribution than the galaxies. If the central gas density is 0.0008 particles/cu cm for gamma = 5/3 or 0.002 per cu cm for gamma = 1.35, the total X-ray emission from a model Coma cluster is equal to the observed emission. The spatial extent and spectrum for the source are also well-represented by the model if gamma = 1.35.

  11. Numerical simulation of landfill gas pressure distribution in landfills.

    Science.gov (United States)

    Xi, Yonghui; Xiong, Hao

    2013-11-01

    Landfill gas emissions are recognized as one of the three major concerns in municipal solid waste landfills. There are many factors that affect the generation of landfill gas when the landfill is capped. In this article, a model has been developed based on the theory of porous media flow. The model could predict the pressure distribution of landfill gas in landfill, coupling the effect of landfill settlement. According to the simulation analysis of landfill, it was found that: (a) the landfill gas pressure would reach a peak after 1.5 years, then begin to decline, and the rate of decay would slow down after 10 years; (b) the influence radius of the gas wells is limited; (c) the peak value of landfill gas pressure is larger, it appears later and the rate of decay is slower when the landfill settlement is considered in the model; (d) the calculation of excess gas pressure in landfill under different negative pressures of the extraction well is compared between this model and another model, and the results show that the relative pressure distribution form and range are almost the same.

  12. Methane Leaks from Natural Gas Systems Follow Extreme Distributions.

    Science.gov (United States)

    Brandt, Adam R; Heath, Garvin A; Cooley, Daniel

    2016-11-15

    Future energy systems may rely on natural gas as a low-cost fuel to support variable renewable power. However, leaking natural gas causes climate damage because methane (CH 4 ) has a high global warming potential. In this study, we use extreme-value theory to explore the distribution of natural gas leak sizes. By analyzing ∼15 000 measurements from 18 prior studies, we show that all available natural gas leakage data sets are statistically heavy-tailed, and that gas leaks are more extremely distributed than other natural and social phenomena. A unifying result is that the largest 5% of leaks typically contribute over 50% of the total leakage volume. While prior studies used log-normal model distributions, we show that log-normal functions poorly represent tail behavior. Our results suggest that published uncertainty ranges of CH 4 emissions are too narrow, and that larger sample sizes are required in future studies to achieve targeted confidence intervals. Additionally, we find that cross-study aggregation of data sets to increase sample size is not recommended due to apparent deviation between sampled populations. Understanding the nature of leak distributions can improve emission estimates, better illustrate their uncertainty, allow prioritization of source categories, and improve sampling design. Also, these data can be used for more effective design of leak detection technologies.

  13. Pyrosequencing Reveals Bacterial Communities in Unchlorinated Drinking Water Distribution System: An Integral Study of Bulk Water, Suspended Solids, Loose Deposits, and Pipe Wall Biofilm

    KAUST Repository

    Liu, G.

    2014-05-20

    The current understanding of drinking water distribution system (DWDS) microbiology is limited to pipe wall biofilm and bulk water; the contributions of particle-associated bacteria (from suspended solids and loose deposits) have long been neglected. Analyzing the composition and correlation of bacterial communities from different phases helped us to locate where most of the bacteria are and understand the interactions among these phases. In the present study, the bacteria from four critical phases of an unchlorinated DWDS, including bulk water, pipe wall biofilm, suspended solids, and loose deposits, were quantified and identified by adenosine triphosphate analysis and pyrosequencing, respectively. The results showed that the bulk water bacteria (including the contribution of suspended solids) contributed less than 2% of the total bacteria. The bacteria associated with loose deposits and pipe wall biofilm that accumulated in the DWDS accounted for over 98% of the total bacteria, and the contributions of bacteria in loose deposits and pipe wall biofilm were comparable. Depending on the amount of loose deposits, its contribution can be 7-fold higher than the pipe wall biofilm. Pyrosequencing revealed relatively stable bacterial communities in bulk water, pipe wall biofilm, and suspended solids throughout the distribution system; however, the communities present in loose deposits were dependent on the amount of loose deposits locally. Bacteria within the phases of suspended solids, loose deposits, and pipe wall biofilm were similar in phylogenetic composition. The bulk water bacteria (dominated by Polaromonas spp.) were clearly different from the bacteria from the other three phases (dominated by Sphingomonas spp.). This study highlighted that the integral DWDS ecology should include contributions from all of the four phases, especially the bacteria harbored by loose deposits. The accumulation of loose deposits and the aging process create variable microenvironments

  14. Pyrosequencing reveals bacterial communities in unchlorinated drinking water distribution system: an integral study of bulk water, suspended solids, loose deposits, and pipe wall biofilm.

    Science.gov (United States)

    Liu, G; Bakker, G L; Li, S; Vreeburg, J H G; Verberk, J Q J C; Medema, G J; Liu, W T; Van Dijk, J C

    2014-05-20

    The current understanding of drinking water distribution system (DWDS) microbiology is limited to pipe wall biofilm and bulk water; the contributions of particle-associated bacteria (from suspended solids and loose deposits) have long been neglected. Analyzing the composition and correlation of bacterial communities from different phases helped us to locate where most of the bacteria are and understand the interactions among these phases. In the present study, the bacteria from four critical phases of an unchlorinated DWDS, including bulk water, pipe wall biofilm, suspended solids, and loose deposits, were quantified and identified by adenosine triphosphate analysis and pyrosequencing, respectively. The results showed that the bulk water bacteria (including the contribution of suspended solids) contributed less than 2% of the total bacteria. The bacteria associated with loose deposits and pipe wall biofilm that accumulated in the DWDS accounted for over 98% of the total bacteria, and the contributions of bacteria in loose deposits and pipe wall biofilm were comparable. Depending on the amount of loose deposits, its contribution can be 7-fold higher than the pipe wall biofilm. Pyrosequencing revealed relatively stable bacterial communities in bulk water, pipe wall biofilm, and suspended solids throughout the distribution system; however, the communities present in loose deposits were dependent on the amount of loose deposits locally. Bacteria within the phases of suspended solids, loose deposits, and pipe wall biofilm were similar in phylogenetic composition. The bulk water bacteria (dominated by Polaromonas spp.) were clearly different from the bacteria from the other three phases (dominated by Sphingomonas spp.). This study highlighted that the integral DWDS ecology should include contributions from all of the four phases, especially the bacteria harbored by loose deposits. The accumulation of loose deposits and the aging process create variable microenvironments

  15. The Gas Distribution in the Outer Regions of Galaxy Clusters

    Science.gov (United States)

    Eckert, D.; Vazza, F.; Ettori, S.; Molendi, S.; Nagai, D.; Lau, E. T.; Roncarelli, M.; Rossetti, M.; Snowden, L.; Gastaldello, F.

    2012-01-01

    Aims. We present our analysis of a local (z = 0.04 - 0.2) sample of 31 galaxy clusters with the aim of measuring the density of the X-ray emitting gas in cluster outskirts. We compare our results with numerical simulations to set constraints on the azimuthal symmetry and gas clumping in the outer regions of galaxy clusters. Methods. We have exploited the large field-of-view and low instrumental background of ROSAT/PSPC to trace the density of the intracluster gas out to the virial radius, We stacked the density profiles to detect a signal beyond T200 and measured the typical density and scatter in cluster outskirts. We also computed the azimuthal scatter of the profiles with respect to the mean value to look for deviations from spherical symmetry. Finally, we compared our average density and scatter profiles with the results of numerical simulations. Results. As opposed to some recent Suzaku results, and confirming previous evidence from ROSAT and Chandra, we observe a steepening of the density profiles beyond approximately r(sub 500). Comparing our density profiles with simulations, we find that non-radiative runs predict density profiles that are too steep, whereas runs including additional physics and/ or treating gas clumping agree better with the observed gas distribution. We report high-confidence detection of a systematic difference between cool-core and non cool-core clusters beyond approximately 0.3r(sub 200), which we explain by a different distribution of the gas in the two classes. Beyond approximately r(sub 500), galaxy clusters deviate significantly from spherical symmetry, with only small differences between relaxed and disturbed systems. We find good agreement between the observed and predicted scatter profiles, but only when the 1% densest clumps are filtered out in the ENZO simulations. Conclusions. Comparing our results with numerical simulations, we find that non-radiative simulations fail to reproduce the gas distribution, even well outside

  16. The Gas Distribution in Galaxy Cluster Outer Regions

    Science.gov (United States)

    Eckert, D.; Vazza, F.; Ettori, S.; Molendi, S.; Nagai, D.; Laue, E. T.; Roncarelli, M.; Rossetti, M.; Snowden, S. L.; Gastaldello, F.

    2012-01-01

    Aims. We present the analysis of a local (z = 0.04 - 0.2) sample of 31 galaxy clusters with the aim of measuring the density of the X-ray emitting gas in cluster outskirts. We compare our results with numerical simulations to set constraints on the azimuthal symmetry and gas clumping in the outer regions of galaxy clusters. Methods. We exploit the large field-of-view and low instrumental background of ROSAT/PSPC to trace the density of the intracluster gas out to the virial radius. We perform a stacking of the density profiles to detect a signal beyond r200 and measure the typical density and scatter in cluster outskirts. We also compute the azimuthal scatter of the profiles with respect to the mean value to look for deviations from spherical symmetry. Finally, we compare our average density and scatter profiles with the results of numerical simulations. Results. As opposed to some recent Suzaku results, and confirming previous evidence from ROSAT and Chandra, we observe a steepening of the density profiles beyond approximately r(sub 500). Comparing our density profiles with simulations, we find that non-radiative runs predict too steep density profiles, whereas runs including additional physics and/or treating gas clumping are in better agreement with the observed gas distribution. We report for the first time the high-confidence detection of a systematic difference between cool-core and non-cool core clusters beyond 0.3r(sub 200), which we explain by a different distribution of the gas in the two classes. Beyond r(sub 500), galaxy clusters deviate significantly from spherical symmetry, with only little differences between relaxed and disturbed systems. We find good agreement between the observed and predicted scatter profiles, but only when the 1% densest clumps are filtered out in the simulations. Conclusions. Comparing our results with numerical simulations, we find that non-radiative simulations fail to reproduce the gas distribution, even well outside cluster

  17. Estimating Predictive Variance for Statistical Gas Distribution Modelling

    International Nuclear Information System (INIS)

    Lilienthal, Achim J.; Asadi, Sahar; Reggente, Matteo

    2009-01-01

    Recent publications in statistical gas distribution modelling have proposed algorithms that model mean and variance of a distribution. This paper argues that estimating the predictive concentration variance entails not only a gradual improvement but is rather a significant step to advance the field. This is, first, since the models much better fit the particular structure of gas distributions, which exhibit strong fluctuations with considerable spatial variations as a result of the intermittent character of gas dispersal. Second, because estimating the predictive variance allows to evaluate the model quality in terms of the data likelihood. This offers a solution to the problem of ground truth evaluation, which has always been a critical issue for gas distribution modelling. It also enables solid comparisons of different modelling approaches, and provides the means to learn meta parameters of the model, to determine when the model should be updated or re-initialised, or to suggest new measurement locations based on the current model. We also point out directions of related ongoing or potential future research work.

  18. Regulatory issues of natural gas distribution; Aspectos regulatorios acerca da distribuicao de gas natural

    Energy Technology Data Exchange (ETDEWEB)

    Leite, Fabio Augusto C.C.M.; Costa, Hirdan Katarina de M. [Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil). Faculdade de Direito

    2004-07-01

    In these past few years, natural gas in Brazil has arised as one of the alternatives for the energetic crisis suffered by the country. Such situation was one of the motives for its expansion, rising, after that, the importance of the regulation of its distribution. The regulation of canalized natural gas distribution can be found in the Federal Constitution, after Constitutional Amendment n. 05/95, in the article n. 25, para. 2nd, which say that belongs to the Federal States the concession or direct exercise of canalized natural gas services, now clearly classified as a public service. In order of these events, its imperative the analysis of natural gas distribution's public service, because it belongs to the Federal States. According to this situation, the study of the new regulatory function of the Administration and the tracing of action for the regulatory state agencies are the main goals of this work. As so, the present research aims to focus the reflexes from the actual dimension of natural gas distribution, specially referring to its regulatory statements, the limitations of state agencies, the National Petroleum Agency and the market where distribution belongs, and particularly the open access of new agents. (author)

  19. Literature review and experimental investigation of heat pipes

    Science.gov (United States)

    Barsch, W. O.; Schoenhals, R. J.; Viskanta, R.; Winter, E. R. F.

    1971-01-01

    Tests on heat pipes determine operational limits, external boundary conditions, noncondensable gas effects, startup behavior, and geometric configurations. Experiment consists of design, construction, and testing of an apparatus for measuring wick properties, conventional heat pipes and coplanar heat pipes.

  20. Visualization of velocity field and phase distribution in gas-liquid two-phase flow by NMR imaging

    International Nuclear Information System (INIS)

    Matsui, G.; Monji, H.; Obata, J.

    2004-01-01

    NMR imaging has been applied in the field of fluid mechanics, mainly single phase flow, to visualize the instantaneous flow velocity field. In the present study, NMR imaging was used to visualize simultaneously both the instantaneous phase structure and velocity field of gas-liquid two-phase flow. Two methods of NMR imaging were applied. One is useful to visualize both the one component of liquid velocity and the phase distribution. This method was applied to horizontal two-phase flow and a bubble rising in stagnant oil. It was successful in obtaining some pictures of velocity field and phase distribution on the cross section of the pipe. The other is used to visualize a two-dimensional velocity field. This method was applied to a bubble rising in a stagnant water. The velocity field was visualized after and before the passage of a bubble at the measuring cross section. Furthermore, the distribution of liquid velocity was obtained. (author)

  1. Gas source localization and gas distribution mapping with a micro-drone

    International Nuclear Information System (INIS)

    Neumann, Patrick P.

    2013-01-01

    The objective of this Ph.D. thesis is the development and validation of a VTOL-based (Vertical Take Off and Landing) micro-drone for the measurement of gas concentrations, to locate gas emission sources, and to build gas distribution maps. Gas distribution mapping and localization of a static gas source are complex tasks due to the turbulent nature of gas transport under natural conditions and becomes even more challenging when airborne. This is especially so, when using a VTOL-based micro-drone that induces disturbances through its rotors, which heavily affects gas distribution. Besides the adaptation of a micro-drone for gas concentration measurements, a novel method for the determination of the wind vector in real-time is presented. The on-board sensors for the flight control of the micro-drone provide a basis for the wind vector calculation. Furthermore, robot operating software for controlling the micro-drone autonomously is developed and used to validate the algorithms developed within this Ph.D. thesis in simulations and real-world experiments. Three biologically inspired algorithms for locating gas sources are adapted and developed for use with the micro-drone: the surge-cast algorithm (a variant of the silkworm moth algorithm), the zigzag / dung beetle algorithm, and a newly developed algorithm called ''pseudo gradient algorithm''. The latter extracts from two spatially separated measuring positions the information necessary (concentration gradient and mean wind direction) to follow a gas plume to its emission source. The performance of the algorithms is evaluated in simulations and real-world experiments. The distance overhead and the gas source localization success rate are used as main performance criteria for comparing the algorithms. Next, a new method for gas source localization (GSL) based on a particle filter (PF) is presented. Each particle represents a weighted hypothesis of the gas source position. As a first step, the PF-based GSL algorithm

  2. Gas source localization and gas distribution mapping with a micro-drone

    Energy Technology Data Exchange (ETDEWEB)

    Neumann, Patrick P.

    2013-07-01

    The objective of this Ph.D. thesis is the development and validation of a VTOL-based (Vertical Take Off and Landing) micro-drone for the measurement of gas concentrations, to locate gas emission sources, and to build gas distribution maps. Gas distribution mapping and localization of a static gas source are complex tasks due to the turbulent nature of gas transport under natural conditions and becomes even more challenging when airborne. This is especially so, when using a VTOL-based micro-drone that induces disturbances through its rotors, which heavily affects gas distribution. Besides the adaptation of a micro-drone for gas concentration measurements, a novel method for the determination of the wind vector in real-time is presented. The on-board sensors for the flight control of the micro-drone provide a basis for the wind vector calculation. Furthermore, robot operating software for controlling the micro-drone autonomously is developed and used to validate the algorithms developed within this Ph.D. thesis in simulations and real-world experiments. Three biologically inspired algorithms for locating gas sources are adapted and developed for use with the micro-drone: the surge-cast algorithm (a variant of the silkworm moth algorithm), the zigzag / dung beetle algorithm, and a newly developed algorithm called ''pseudo gradient algorithm''. The latter extracts from two spatially separated measuring positions the information necessary (concentration gradient and mean wind direction) to follow a gas plume to its emission source. The performance of the algorithms is evaluated in simulations and real-world experiments. The distance overhead and the gas source localization success rate are used as main performance criteria for comparing the algorithms. Next, a new method for gas source localization (GSL) based on a particle filter (PF) is presented. Each particle represents a weighted hypothesis of the gas source position. As a first step, the PF

  3. Earthquake Risk Reduction to Istanbul Natural Gas Distribution Network

    Science.gov (United States)

    Zulfikar, Can; Kariptas, Cagatay; Biyikoglu, Hikmet; Ozarpa, Cevat

    2017-04-01

    Earthquake Risk Reduction to Istanbul Natural Gas Distribution Network Istanbul Natural Gas Distribution Corporation (IGDAS) is one of the end users of the Istanbul Earthquake Early Warning (EEW) signal. IGDAS, the primary natural gas provider in Istanbul, operates an extensive system 9,867km of gas lines with 750 district regulators and 474,000 service boxes. The natural gas comes to Istanbul city borders with 70bar in 30inch diameter steel pipeline. The gas pressure is reduced to 20bar in RMS stations and distributed to district regulators inside the city. 110 of 750 district regulators are instrumented with strong motion accelerometers in order to cut gas flow during an earthquake event in the case of ground motion parameters exceeds the certain threshold levels. Also, state of-the-art protection systems automatically cut natural gas flow when breaks in the gas pipelines are detected. IGDAS uses a sophisticated SCADA (supervisory control and data acquisition) system to monitor the state-of-health of its pipeline network. This system provides real-time information about quantities related to pipeline monitoring, including input-output pressure, drawing information, positions of station and RTU (remote terminal unit) gates, slum shut mechanism status at 750 district regulator sites. IGDAS Real-time Earthquake Risk Reduction algorithm follows 4 stages as below: 1) Real-time ground motion data transmitted from 110 IGDAS and 110 KOERI (Kandilli Observatory and Earthquake Research Institute) acceleration stations to the IGDAS Scada Center and KOERI data center. 2) During an earthquake event EEW information is sent from IGDAS Scada Center to the IGDAS stations. 3) Automatic Shut-Off is applied at IGDAS district regulators, and calculated parameters are sent from stations to the IGDAS Scada Center and KOERI. 4) Integrated building and gas pipeline damage maps are prepared immediately after the earthquake event. The today's technology allows to rapidly estimate the

  4. Gas-Fired Distributed Energy Resource Technology Characterizations

    Energy Technology Data Exchange (ETDEWEB)

    Goldstein, L.; Hedman, B.; Knowles, D.; Freedman, S. I.; Woods, R.; Schweizer, T.

    2003-11-01

    The U. S. Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy (EERE) is directing substantial programs in the development and encouragement of new energy technologies. Among them are renewable energy and distributed energy resource technologies. As part of its ongoing effort to document the status and potential of these technologies, DOE EERE directed the National Renewable Energy Laboratory to lead an effort to develop and publish Distributed Energy Technology Characterizations (TCs) that would provide both the department and energy community with a consistent and objective set of cost and performance data in prospective electric-power generation applications in the United States. Toward that goal, DOE/EERE - joined by the Electric Power Research Institute (EPRI) - published the Renewable Energy Technology Characterizations in December 1997.As a follow-up, DOE EERE - joined by the Gas Research Institute - is now publishing this document, Gas-Fired Distributed Energy Resource Technology Characterizations.

  5. A scaling law of radial gas distribution in disk galaxies

    Science.gov (United States)

    Wang, Zhong

    1990-01-01

    Based on the idea that local conditions within a galactic disk largely determine the region's evolution time scale, researchers built a theoretical model to take into account molecular cloud and star formations in the disk evolution process. Despite some variations that may be caused by spiral arms and central bulge masses, they found that many late-type galaxies show consistency with the model in their radial atomic and molecular gas profiles. In particular, researchers propose that a scaling law be used to generalize the gas distribution characteristics. This scaling law may be useful in helping to understand the observed gas contents in many galaxies. Their model assumes an exponential mass distribution with disk radius. Most of the mass are in atomic gas state at the beginning of the evolution. Molecular clouds form through a modified Schmidt Law which takes into account gravitational instabilities in a possible three-phase structure of diffuse interstellar medium (McKee and Ostriker, 1977; Balbus and Cowie, 1985); whereas star formation proceeds presumably unaffected by the environmental conditions outside of molecular clouds (Young, 1987). In such a model both atomic and molecular gas profiles in a typical galactic disk (as a result of the evolution) can be fitted simultaneously by adjusting the efficiency constants. Galaxies of different sizes and masses, on the other hand, can be compared with the model by simply scaling their characteristic length scales and shifting their radial ranges to match the assumed disk total mass profile sigma tot(r).

  6. Having our gas and selling it too : natural gas distribution in Atlantic Canada

    International Nuclear Information System (INIS)

    Tucker, T.L.; Crowley, B.L.

    2002-01-01

    This paper presented an overview of the gas industry in Atlantic Canada, its history and development, with particular attention to the future of natural gas in Atlantic Canada, market pricing and rationalized regulation. It also includes a primer on the economic forces behind the industry. A regulatory framework was recommended that will provide gas to the greatest number of consumers at the lowest possible price. The report also describes 10 popular misconceptions regarding how the region believes it can best benefit from natural gas. The report dispels the idea that the greatest benefit comes from consuming natural gas locally. Other misconceptions are that gas can be sold locally at discount prices and at a premium to export markets. It was emphasized that Atlantic Canada needs the gas as much as New England markets, but the investment by consumers in the United States are a big driving force for offshore gas development. The author emphasized that even if Atlantic Canada never consumes its own natural gas, the royalties, economic growth, economic diversification and a new addition to the energy mix will generate benefits much greater than those which could come from local consumption alone. The author also suggests that the lack of market power in Atlantic Canada means that gas-specific provincial regulations to protect the public interest are not required. It was suggested that a gas distributor should be chosen to build the infrastructure and attract customers. This paper demonstrated that the greatest benefit to the region will come from deregulating the distribution industry while realizing the full market value of the gas for its owners. 15 refs

  7. 46 CFR 119.430 - Engine exhaust pipe installation.

    Science.gov (United States)

    2010-10-01

    ... an exhaust pipe. (b) Exhaust gas must not leak from the piping or any connections. The piping must be... stresses resulting from the expansion of the exhaust piping. (g) A dry exhaust pipe must: (1) If it passes... discharge terminating in a transom must be located as far outboard as practicable so that exhaust gases...

  8. Research on the internal pressure behavior of metal gas distribution pipelines with different types of tubing defects

    Directory of Open Access Journals (Sweden)

    Filip Stefan Mihai

    2017-01-01

    Full Text Available The paper aims to approach an important subject related to natural gas distribution networks which, depending on the expansion of the localities, are composed of intercommunicating pipes, pressure reducing stations and branch connections fittings. The urban networks are the most complex ones and the rural areas networks are the simplest. However, irrespective of their installation, they must meet the safety operating requirements as much as possible. According to standards, all these components must be tight and pressure resistant. In this regard, we intend to approach a very important issue related to the behavior of the tubular steel material showing corrosion and/or material defects, and to the internal stress caused by the gas pressure on the walls of the tubing material.

  9. Holographic NDT methods for plastic pipe vibration and brittle crack propagation analysis

    Science.gov (United States)

    Markov, Vladimir B.; Boone, Pierre M.; Vanspeybroeck, Philippe

    1995-11-01

    Plastic pipes are frequently used for low pressure gas and water distribution. One of the main problems with their wide commercial applications is rapid crack propagation (RCP). This results in enormous losses of energy resources and environment pollution. Recent incidents show that it is of importance to find criteria to assess the safety conditions for large diameter piping before its installation. In this report some results of holographic non-destructive testing of plastic pipes are presented. Double-pulse holographic interferometry measurements of stress distribution at small scale steady state (S4) tests for 3 - 5 bar pressurized plastic pipes with (phi) 110 mm to 200 mm were performed. Also the mechanically induced vibration modes of non-pressurized (phi) 200 mm plastic pipe were visualized with the purpose to check stress distribution.

  10. Evaluation of residual stress distribution of butt-weld pipe and redistribution behavior with crack extension using neutron diffraction method

    International Nuclear Information System (INIS)

    Okido, Shinobu; Hayashi, Makoto; Minakawa, Nobuaki; Morii, Yukio; Ando, Kotoji

    2005-01-01

    Residual stress is known to be redistributed as a result of crack extension. The neutron diffraction method was used to evaluate this residual stress redistribution, using a specimen consisting of a butt-weld-jointed pipe made of type-304 austenitic stainless steel (inner diameter φ=97.1 mm, thickness t=8.9mm). Half-elliptical cracks were introduced by an electrical discharge machining at the inner surface of a heat-affected zone. The ratios of a/t, for crack depth a and specimen thickness t, were 0.25 and 0.5, with aspect ratios a/c, for crack half-length c, of 0.1 and 0.5 Comparing the residual stress distribution before and after the crack introduction showed that although the residual stress distribution along the line of the ligament at the deepest point of the crack changed slightly in front of the crack tip, it did not change throughout the ligament. This result shows that residual stress redistributes through-out in the whole crack tip region, including the width of the crack. (author)

  11. Characterization of biofilm and corrosion of cast iron pipes in drinking water distribution system with UV/Cl2 disinfection.

    Science.gov (United States)

    Zhu, Ying; Wang, Haibo; Li, Xiaoxiao; Hu, Chun; Yang, Min; Qu, Jiuhui

    2014-09-01

    The effect of UV/Cl2 disinfection on the biofilm and corrosion of cast iron pipes in drinking water distribution system were studied using annular reactors (ARs). Passivation occurred more rapidly in the AR with UV/Cl2 than in the one with Cl2 alone, decreasing iron release for higher corrosivity of water. Based on functional gene, pyrosequencing assays and principal component analysis, UV disinfection not only reduced the required initial chlorine dose, but also enhanced denitrifying functional bacteria advantage in the biofilm of corrosion scales. The nitrate-reducing bacteria (NRB) Dechloromonas exhibited the greatest corrosion inhibition by inducing the redox cycling of iron to enhance the precipitation of iron oxides and formation of Fe3O4 in the AR with UV/Cl2, while the rhizobia Bradyrhizobium and Rhizobium, and the NRB Sphingomonas, Brucella producing siderophores had weaker corrosion-inhibition effect by capturing iron in the AR with Cl2. These results indicated that the microbial redox cycling of iron was possibly responsible for higher corrosion inhibition and lower effect of water Larson-Skold Index (LI) changes on corrosion. This finding could be applied toward the control of water quality in drinking water distribution systems. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Volatile organic compounds in natural biofilm in polyethylene pipes supplied with lake water and treated water from the distribution network.

    Science.gov (United States)

    Skjevrak, Ingun; Lund, Vidar; Ormerod, Kari; Herikstad, Hallgeir

    2005-10-01

    The objective of this work was investigation of volatile organic compounds (VOC) in natural biofilm inside polyethylene (HDPE) pipelines at continuously flowing water. VOC in biofilm may contribute to off-flavour episodes in drinking water. The pipelines were supplied with raw lake water and treated water from the distribution network. Biofilm was established at test sites located at two different drinking water distribution networks and their raw water sources. A whole range of volatile compounds were identified in the biofilm, including compounds frequently associated with cyanobacteria and algae, such as ectocarpene, dictyopterene A and C', geosmin, beta-ionone and 6-methyl-5-hepten-2-one. In addition, volatile amines, dimethyldisulphide and 2-nonanone, presumably originating from microorganisms growing in the biofilm, were identified. C8-compounds such as 1-octen-3-one and 3-octanone were believed to be products from microfungi in the biofilm. Degradation products from antioxidants such as Irgafos 168, Irganox 1010 and Irganox 1076 used in HDPE pipes, corresponding to 2,4-di-tert-butylphenol and 2,6-di-tert-butylbenzoquinone, were present in the biofilm.

  13. Government information report to the parliament. The gas distribution in France

    International Nuclear Information System (INIS)

    2002-11-01

    This report evaluates the gas distribution state in France and presents the forecasts of the gas energy use development by the gas utilities users. In this framework the following points are presented: the juridical aspects of the gas distribution, the national plan of distribution, the new legislation occurring from the gas market deregulation and some statistical data on the gas use, consumption and demand in France. (A.L.B.)

  14. Momentum Distribution in the Unitary Bose Gas from First Principles.

    Science.gov (United States)

    Comparin, Tommaso; Krauth, Werner

    2016-11-25

    We consider a realistic bosonic N-particle model with unitary interactions relevant for Efimov physics. Using quantum Monte Carlo methods, we find that the critical temperature for Bose-Einstein condensation is decreased with respect to the ideal Bose gas. We also determine the full momentum distribution of the gas, including its universal asymptotic behavior, and compare this crucial observable to recent experimental data. Similar to the experiments with different atomic species, differentiated solely by a three-body length scale, our model only depends on a single parameter. We establish a weak influence of this parameter on physical observables. In current experiments, the thermodynamic instability of our model from the atomic gas towards an Efimov liquid could be masked by the dynamical instability due to three-body losses.

  15. Gas-leak localization using distributed ultrasonic sensors

    Science.gov (United States)

    Huseynov, Javid; Baliga, Shankar; Dillencourt, Michael; Bic, Lubomir; Bagherzadeh, Nader

    2009-03-01

    We propose an ultrasonic gas leak localization system based on a distributed network of sensors. The system deploys highly sensitive miniature Micro-Electro-Mechanical Systems (MEMS) microphones and uses a suite of energy-decay (ED) and time-delay of arrival (TDOA) algorithms for localizing a source of a gas leak. Statistical tools such as the maximum likelihood (ML) and the least squares (LS) estimators are used for approximating the source location when closed-form solutions fail in the presence of ambient background nuisance and inherent electronic noise. The proposed localization algorithms were implemented and tested using a Java-based simulation platform connected to four or more distributed MEMS microphones observing a broadband nitrogen leak from an orifice. The performance of centralized and decentralized algorithms under ED and TDOA schemes is analyzed and compared in terms of communication overhead and accuracy in presence of additive white Gaussian noise (AWGN).

  16. Risk analysis for a local gas distribution network

    International Nuclear Information System (INIS)

    Peters, J.W.

    1991-01-01

    Cost control and service reliability are popular topics when discussing strategic issues facing local distribution companies (LDCs) in the 1990s. The ability to provide secure and uninterrupted gas service is crucial for growth and company image, both with the public and regulatory agencies. At the same time, the industry is facing unprecedented competition from alternate fuels, and cost control is essential for maintaining a competitive edge in the market. On the surface, it would appear that cost control and service reliability are contradictory terms. Improvement in service reliability should cost something, or does it? Risk analysis can provide the answer from a distribution design perspective. From a gas distribution engineer's perspective, projects such as loops, backfeeds and even valve placement are designed to reduce, minimize and/or eliminate potential customer outages. These projects improve service reliability by acting as backups should a failure occur on a component of the distribution network. These contingency projects are cost-effective but their longterm benefit or true value is under question. Their purpose is to maintain supply to an area in the distribution network in the event of a failure somewhere else. Two phrases, potential customer outages and in the event of failure, identify uncertainty

  17. Distributed gas sensing with optical fibre photothermal interferometry.

    Science.gov (United States)

    Lin, Yuechuan; Liu, Fei; He, Xiangge; Jin, Wei; Zhang, Min; Yang, Fan; Ho, Hoi Lut; Tan, Yanzhen; Gu, Lijuan

    2017-12-11

    We report the first distributed optical fibre trace-gas detection system based on photothermal interferometry (PTI) in a hollow-core photonic bandgap fibre (HC-PBF). Absorption of a modulated pump propagating in the gas-filled HC-PBF generates distributed phase modulation along the fibre, which is detected by a dual-pulse heterodyne phase-sensitive optical time-domain reflectometry (OTDR) system. Quasi-distributed sensing experiment with two 28-meter-long HC-PBF sensing sections connected by single-mode transmission fibres demonstrated a limit of detection (LOD) of ∼10 ppb acetylene with a pump power level of 55 mW and an effective noise bandwidth (ENBW) of 0.01 Hz, corresponding to a normalized detection limit of 5.5ppb⋅W/Hz. Distributed sensing experiment over a 200-meter-long sensing cable made of serially connected HC-PBFs demonstrated a LOD of ∼ 5 ppm with 62.5 mW peak pump power and 11.8 Hz ENBW, or a normalized detection limit of 312ppb⋅W/Hz. The spatial resolution of the current distributed detection system is limited to ∼ 30 m, but it is possible to reduce down to 1 meter or smaller by optimizing the phase detection system.

  18. 75 FR 59705 - SourceGas Distribution LLC; Bay Gas Storage, LLC; Enterprise Texas Pipeline LLC; Dow Intrastate...

    Science.gov (United States)

    2010-09-28

    ...; Docket No. PR10-110-000; Docket No. PR10-112-000; Docket No. PR10- 113-000 (Not Consolidated) SourceGas Distribution LLC; Bay Gas Storage, LLC; Enterprise Texas Pipeline LLC; Dow Intrastate Gas Company; ONEOK Field Services Company, L.L.C.; Corning Natural Gas Corporation; Notice of Baseline Filings September 21, 2010...

  19. Distribution of concentration of coarse particle-water mixture in horizontal smooth pipe

    Czech Academy of Sciences Publication Activity Database

    Vlasák, Pavel; Chára, Zdeněk; Konfršt, Jiří; Krupička, Jan

    2016-01-01

    Roč. 94, č. 6 (2016), s. 1040-1047 ISSN 0008-4034 R&D Projects: GA ČR GAP105/10/1574 Institutional support: RVO:67985874 Keywords : coarse particle-water mixture * gamma-ray radiometry * concentration distribution * horizontal conveying Subject RIV: BK - Fluid Dynamics Impact factor: 1.356, year: 2016

  20. 46 CFR 153.280 - Piping system design.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Piping system design. 153.280 Section 153.280 Shipping... BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Piping Systems and Cargo Handling Equipment § 153.280 Piping system design. (a) Each cargo piping system must meet...

  1. Studies on the characteristics of the separated heat pipe system with non-condensible gas for the use of the passive decay heat removal in reactor systems

    International Nuclear Information System (INIS)

    Hayashi, Takao; Ishi, Takayuki; Hayakawa, Hitoshi; Ohashi, Kazutaka

    1997-01-01

    Experiments on the separated heat pipe system of variable conductance type, which enclose non-condensible gas, have been carried out with intention of applying such system to passive decay heat removal of the modular reactors such as HTR plant. Basic experiments have been carried out on the experimental apparatus consisting of evaporator, vapor transfer tube, condenser tube and return tube which returns the condensed liquid back to the evaporator. Water and methanol were examined as the working fluids and nitrogen gas was enclosed as the non-condensible gas. The behaviors of the system were examined for the parametric changes of the heat input under the various pressures of nitrogen gas initially enclosed, including the case without enclosing N 2 gas for the comparison. The results of the experiments shows very clear features of self control characteristics. The self control mechanism was made clear, that is, in such system in which the condensing area in the condenser expands automatically in accordance with the increase of the heat input to keep the system temperature nearly constant. The working temperature of the system are clearly dependent on the pressure of the non-condensable gas initially enclosed, with higher system working temperature with higher initial gas pressure enclosed. The analyses were done on water and methanol as the working fluids, which show very good agreement with the experimental results. A lot of attractive applications are expected including the self switching feature with minimum heat loss during normal operation with maintaining the sufficient heat removal at accidents. (author)

  2. Image-processing of time-averaged interface distributions representing CCFL characteristics in a large scale model of a PWR hot-leg pipe geometry

    International Nuclear Information System (INIS)

    Al Issa, Suleiman; Macián-Juan, Rafael

    2017-01-01

    Highlights: • CCFL characteristics are investigated in PWR large-scale hot-leg pipe geometry. • Image processing of air-water interface produced time-averaged interface distributions. • Time-averages provide a comparative method of CCFL characteristics among different studies. • CCFL correlations depend upon the range of investigated water delivery for Dh ≫ 50 mm. • 1D codes are incapable of investigating CCFL because of lack of interface distribution. - Abstract: Countercurrent Flow Limitation (CCFL) was experimentally investigated in a 1/3.9 downscaled COLLIDER facility with a 190 mm pipe’s diameter using air/water at 1 atmospheric pressure. Previous investigations provided knowledge over the onset of CCFL mechanisms. In current article, CCFL characteristics at the COLLIDER facility are measured and discussed along with time-averaged distributions of the air/water interface for a selected matrix of liquid/gas velocities. The article demonstrates the time-averaged interface as a useful method to identify CCFL characteristics at quasi-stationary flow conditions eliminating variations that appears in single images, and showing essential comparative flow features such as: the degree of restriction at the bend, the extension and the intensity of the two-phase mixing zones, and the average water level within the horizontal part and the steam generator. Consequently, making it possible to compare interface distributions obtained at different investigations. The distributions are also beneficial for CFD validations of CCFL as the instant chaotic gas/liquid interface is impossible to reproduce in CFD simulations. The current study shows that final CCFL characteristics curve (and the corresponding CCFL correlation) depends upon the covered measuring range of water delivery. It also shows that a hydraulic diameter should be sufficiently larger than 50 mm in order to obtain CCFL characteristics comparable to the 1:1 scale data (namely the UPTF data). Finally

  3. A novel radial anode layer ion source for inner wall pipe coating and materials modification--hydrogenated diamond-like carbon coatings from butane gas.

    Science.gov (United States)

    Murmu, Peter P; Markwitz, Andreas; Suschke, Konrad; Futter, John

    2014-08-01

    We report a new ion source development for inner wall pipe coating and materials modification. The ion source deposits coatings simultaneously in a 360° radial geometry and can be used to coat inner walls of pipelines by simply moving the ion source in the pipe. Rotating parts are not required, making the source ideal for rough environments and minimizing maintenance and replacements of parts. First results are reported for diamond-like carbon (DLC) coatings on Si and stainless steel substrates deposited using a novel 360° ion source design. The ion source operates with permanent magnets and uses a single power supply for the anode voltage and ion acceleration up to 10 kV. Butane (C4H10) gas is used to coat the inner wall of pipes with smooth and homogeneous DLC coatings with thicknesses up to 5 μm in a short time using a deposition rate of 70 ± 10 nm min(-1). Rutherford backscattering spectrometry results showed that DLC coatings contain hydrogen up to 30 ± 3% indicating deposition of hydrogenated DLC (a-C:H) coatings. Coatings with good adhesion are achieved when using a multiple energy implantation regime. Raman spectroscopy results suggest slightly larger disordered DLC layers when using low ion energy, indicating higher sp(3) bonds in DLC coatings. The results show that commercially interesting coatings can be achieved in short time.

  4. Mathematical model of nonisothermal turbulent flow of gas suspension in a pipe on the basis of the mixed Eulerian-Lagrangian representation

    International Nuclear Information System (INIS)

    Starchenko, A.V.; Bubenchikov, A.M.; Burlutskij, E.S.

    2002-01-01

    The mathematical model of the gas suspension nonisothermal turbulent flow in a pipe is formulated within the frames of the mixed Eulerian-Lagrangian representation. The model testing showed good agreement of the calculational results with the experiments as well as with the continuous model data. Application of two essentially differing approaches (the continuous and mixed ones) to modeling the density flow practically to similar results by the fields of averaged velocities and temperatures as well as by the coefficient of accommodation of the tangential velocity component and essentially of the particles collision with the wall surface [ru

  5. 75 FR 38781 - Certain Large Diameter Carbon and Alloy Seamless Standard, Line, and Pressure Pipe From Japan...

    Science.gov (United States)

    2010-07-06

    ... conveyance of water, steam, natural gas, air and other liquids and gasses in plumbing and heating systems... line applications such as oil, gas, or water pipeline, or utility distribution systems. Seamless..., natural gas and other liquids and gasses in industrial piping systems. They may carry these substances at...

  6. DISTRIBUTION OF FAINT ATOMIC GAS IN HICKSON COMPACT GROUPS

    Energy Technology Data Exchange (ETDEWEB)

    Borthakur, Sanchayeeta; Heckman, Timothy M.; Zhu, Guangtun [Department of Physics and Astronomy, Johns Hopkins University, Baltimore, MD 21218 (United States); Yun, Min Su [Astronomy Department, University of Massachusetts, Amherst, MA 01003 (United States); Verdes-Montenegro, Lourdes [Instituto de Astrofísica de Andalucía, CSIC, Apdo. Correos 3004, E-18080 Granada (Spain); Braatz, James A., E-mail: sanch@pha.jhu.edu [National Radio Astronomy Observatory, 520 Edgemont Road, Charlottesville, VA 22903 (United States)

    2015-10-10

    We present 21 cm H i observations of four Hickson Compact Groups (HCGs) with evidence for a substantial intragroup medium using the Robert C. Byrd Green Bank Telescope (GBT). By mapping H i emission in a region of 25′ × 25′ (140–650 kpc) surrounding each HCG, these observations provide better estimates of H i masses. In particular, we detected 65% more H i than that detected in the Karl G. Jansky Very Large Array (VLA) imaging of HCG 92. We also identify whether the diffuse gas has the same spatial distribution as the high surface brightness (HSB) H i features detected in the VLA maps of these groups by comparing the H i strengths between the observed and modeled masses based on VLA maps. We found that the H i observed with the GBT has a similar spatial distribution to the HSB structures in HCG 31 and HCG 68. Conversely, the observed H i distributions in HCG 44 and HCG 92 were extended and showed significant offsets from the modeled masses. Most of the faint gas in HCG 44 lies to the northeast–southwest region and in HCG 92 lies in the northwest region of their respective groups. The spatial and dynamical similarities between the total (faint+HSB) and the HSB H i indicate that the faint gas is of tidal origin. We found that the gas will survive ionization by the cosmic UV background and the escaping ionizing photons from the star-forming regions and stay primarily neutral for at least 500 Myr.

  7. Natural gas power generation: interruptible gas distribution network regulation; Geracao termoeletrica a gas natural: regulacao do segmento interruptivel de distribuicao de gas canalizado

    Energy Technology Data Exchange (ETDEWEB)

    Paula, Claudio Paiva de; Kann, Zevi [Agencia Reguladora de Saneamento e Energia do Estado de Sao Paulo (ARSESP), SP (Brazil)

    2008-07-01

    The paper relates studies regarding the natural gas distribution network interruptible branch. This new service can be appropriate for thermal power generation on flexible dispatch mode, as 'take or pay' contracts surplus jobs. The paper indicates no regulatory restraints in an interruptible network implantation. The final conclusion is that interruptible contracts can be an improvement on the distribution business and certainly can accommodate a suitable demand and supply volumes in the long-term gas market balance. (author)

  8. Reliability-based assessment of polyethylene pipe creep lifetime

    Energy Technology Data Exchange (ETDEWEB)

    Khelif, Rabia [LaMI-UBP and IFMA, Campus de Clermont-Fd, Les Cezeaux, BP 265, 63175 Aubiere Cedex (France); LR3MI, Departement de Genie Mecanique, Universite Badji Mokhtar, BP 12, Annaba 23000 (Algeria)], E-mail: rabia.khelif@ifma.fr; Chateauneuf, Alaa [LGC-University Blaise Pascal, Campus des Cezeaux, BP 206, 63174 Aubiere Cedex (France)], E-mail: alaa.chateauneuf@polytech.univ-bpclermont.fr; Chaoui, Kamel [LR3MI, Departement de Genie Mecanique, Universite Badji Mokhtar, BP 12, Annaba 23000 (Algeria)], E-mail: chaoui@univ-annaba.org

    2007-12-15

    Lifetime management of underground pipelines is mandatory for safe hydrocarbon transmission and distribution systems. The use of high-density polyethylene tubes subjected to internal pressure, external loading and environmental variations requires a reliability study in order to define the service limits and the optimal operating conditions. In service, the time-dependent phenomena, especially creep, take place during the pipe lifetime, leading to significant strength reduction. In this work, the reliability-based assessment of pipe lifetime models is carried out, in order to propose a probabilistic methodology for lifetime model selection and to determine the pipe safety levels as well as the most important parameters for pipeline reliability. This study is enhanced by parametric analysis on pipe configuration, gas pressure and operating temperature.

  9. Reliability-based assessment of polyethylene pipe creep lifetime

    International Nuclear Information System (INIS)

    Khelif, Rabia; Chateauneuf, Alaa; Chaoui, Kamel

    2007-01-01

    Lifetime management of underground pipelines is mandatory for safe hydrocarbon transmission and distribution systems. The use of high-density polyethylene tubes subjected to internal pressure, external loading and environmental variations requires a reliability study in order to define the service limits and the optimal operating conditions. In service, the time-dependent phenomena, especially creep, take place during the pipe lifetime, leading to significant strength reduction. In this work, the reliability-based assessment of pipe lifetime models is carried out, in order to propose a probabilistic methodology for lifetime model selection and to determine the pipe safety levels as well as the most important parameters for pipeline reliability. This study is enhanced by parametric analysis on pipe configuration, gas pressure and operating temperature

  10. Co-current air-water flow in downward sloping pipes : Transport of capacity reducing gas pockets in wastewater mains

    NARCIS (Netherlands)

    Pothof, I.W.M.

    2011-01-01

    Air-water flow is an undesired condition in many systems for the transportation of water or wastewater. Air in storm water tunnels may get trapped and negatively affect the system. Air pockets in hydropower tunnels or sewers may cause blow-back events and inadmissible pressure spikes. Water pipes

  11. Measurements of gravity and gravity-capillary waves in horizontal gas-liquid pipe flow using PIV in both phases

    NARCIS (Netherlands)

    Birvalski, M.; Tummers, M.J.; Henkes, R.A.W.M.

    2016-01-01

    An experimental study was performed in stratified wavy flow of air and water through a horizontal pipe. The velocity fields in both phases were measured simultaneously using PIV and the interfacial shape was resolved using a profile capturing technique. The objective of the study was to

  12. Inhomogeneous Oxygen Vacancy Distribution in Semiconductor Gas Sensors: Formation, Migration and Determination on Gas Sensing Characteristics.

    Science.gov (United States)

    Liu, Jianqiao; Gao, Yinglin; Wu, Xu; Jin, Guohua; Zhai, Zhaoxia; Liu, Huan

    2017-08-10

    The density of oxygen vacancies in semiconductor gas sensors was often assumed to be identical throughout the grain in the numerical discussion of the gas-sensing mechanism of the devices. In contrast, the actual devices had grains with inhomogeneous distribution of oxygen vacancy under non-ideal conditions. This conflict between reality and discussion drove us to study the formation and migration of the oxygen defects in semiconductor grains. A model of the gradient-distributed oxygen vacancy was proposed based on the effects of cooling rate and re-annealing on semiconductive thin films. The model established the diffusion equations of oxygen vacancy according to the defect kinetics of diffusion and exclusion. We described that the steady-state and transient-state oxygen vacancy distributions, which were used to calculate the gas-sensing characteristics of the sensor resistance and response to reducing gases under two different conditions. The gradient-distributed oxygen vacancy model had the applications in simulating the sensor performances, such as the power law, the grain size effect and the effect of depletion layer width.

  13. Inhomogeneous Oxygen Vacancy Distribution in Semiconductor Gas Sensors: Formation, Migration and Determination on Gas Sensing Characteristics

    Directory of Open Access Journals (Sweden)

    Jianqiao Liu

    2017-08-01

    Full Text Available The density of oxygen vacancies in semiconductor gas sensors was often assumed to be identical throughout the grain in the numerical discussion of the gas-sensing mechanism of the devices. In contrast, the actual devices had grains with inhomogeneous distribution of oxygen vacancy under non-ideal conditions. This conflict between reality and discussion drove us to study the formation and migration of the oxygen defects in semiconductor grains. A model of the gradient-distributed oxygen vacancy was proposed based on the effects of cooling rate and re-annealing on semiconductive thin films. The model established the diffusion equations of oxygen vacancy according to the defect kinetics of diffusion and exclusion. We described that the steady-state and transient-state oxygen vacancy distributions, which were used to calculate the gas-sensing characteristics of the sensor resistance and response to reducing gases under two different conditions. The gradient-distributed oxygen vacancy model had the applications in simulating the sensor performances, such as the power law, the grain size effect and the effect of depletion layer width.

  14. In-Situ Measurements of Low Enrichment Uranium Holdup Process Gas Piping at K-25 - Paper for Waste Management Symposia 2010 East Tennessee Technology Park Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    Rasmussen, B.

    2010-01-01

    This document is the final version of a paper submitted to the Waste Management Symposia, Phoenix, 2010, abstract BJC/OR-3280. The primary document from which this paper was condensed is In-Situ Measurement of Low Enrichment Uranium Holdup in Process Gas Piping at K-25 Using NaI/HMS4 Gamma Detection Systems, BJC/OR-3355. This work explores the sufficiency and limitations of the Holdup Measurement System 4 (HJVIS4) software algorithms applied to measurements of low enriched uranium holdup in gaseous diffusion process gas piping. HMS4 has been used extensively during the decommissioning and demolition project of the K-25 building for U-235 holdup quantification. The HMS4 software is an integral part of one of the primary nondestructive assay (NDA) systems which was successfully tested and qualified for holdup deposit quantification in the process gas piping of the K-25 building. The initial qualification focused on the measurement of highly enriched UO 2 F 2 deposits. The purpose of this work was to determine if that qualification could be extended to include the quantification of holdup in UO 2 F 2 deposits of lower enrichment. Sample field data are presented to provide evidence in support of the theoretical foundation. The HMS4 algorithms were investigated in detail and found to sufficiently compensate for UO 2 F 2 source self-attenuation effects, over the range of expected enrichment (4-40%), in the North and East Wings of the K-25 building. The limitations of the HMS4 algorithms were explored for a described set of conditions with respect to area source measurements of low enriched UO 2 F 2 deposits when used in conjunction with a 1 inch by 1/2 inch sodium iodide (NaI) scintillation detector. The theoretical limitations of HMS4, based on the expected conditions in the process gas system of the K-25 building, are related back to the required data quality objectives (DQO) for the NBA measurement system established for the K-25 demolition project. The combined

  15. In-Situ Measurements of Low Enrichment Uranium Holdup Process Gas Piping at K-25 - Paper for Waste Management Symposia 2010 East Tennessee Technology Park Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    Rasmussen B.

    2010-01-01

    This document is the final version of a paper submitted to the Waste Management Symposia, Phoenix, 2010, abstract BJC/OR-3280. The primary document from which this paper was condensed is In-Situ Measurement of Low Enrichment Uranium Holdup in Process Gas Piping at K-25 Using NaI/HMS4 Gamma Detection Systems, BJC/OR-3355. This work explores the sufficiency and limitations of the Holdup Measurement System 4 (HJVIS4) software algorithms applied to measurements of low enriched uranium holdup in gaseous diffusion process gas piping. HMS4 has been used extensively during the decommissioning and demolition project of the K-25 building for U-235 holdup quantification. The HMS4 software is an integral part of one of the primary nondestructive assay (NDA) systems which was successfully tested and qualified for holdup deposit quantification in the process gas piping of the K-25 building. The initial qualification focused on the measurement of highly enriched UO{sub 2}F{sub 2} deposits. The purpose of this work was to determine if that qualification could be extended to include the quantification of holdup in UO{sub 2}F{sub 2} deposits of lower enrichment. Sample field data are presented to provide evidence in support of the theoretical foundation. The HMS4 algorithms were investigated in detail and found to sufficiently compensate for UO{sub 2}F{sub 2} source self-attenuation effects, over the range of expected enrichment (4-40%), in the North and East Wings of the K-25 building. The limitations of the HMS4 algorithms were explored for a described set of conditions with respect to area source measurements of low enriched UO{sub 2}F{sub 2} deposits when used in conjunction with a 1 inch by 1/2 inch sodium iodide (NaI) scintillation detector. The theoretical limitations of HMS4, based on the expected conditions in the process gas system of the K-25 building, are related back to the required data quality objectives (DQO) for the NBA measurement system established for the K-25

  16. Use of the truncated shifted Pareto distribution in assessing size distribution of oil and gas fields

    Science.gov (United States)

    Houghton, J.C.

    1988-01-01

    The truncated shifted Pareto (TSP) distribution, a variant of the two-parameter Pareto distribution, in which one parameter is added to shift the distribution right and left and the right-hand side is truncated, is used to model size distributions of oil and gas fields for resource assessment. Assumptions about limits to the left-hand and right-hand side reduce the number of parameters to two. The TSP distribution has advantages over the more customary lognormal distribution because it has a simple analytic expression, allowing exact computation of several statistics of interest, has a "J-shape," and has more flexibility in the thickness of the right-hand tail. Oil field sizes from the Minnelusa play in the Powder River Basin, Wyoming and Montana, are used as a case study. Probability plotting procedures allow easy visualization of the fit and help the assessment. ?? 1988 International Association for Mathematical Geology.

  17. Finding robust investments for the Dutch gas distribution infrastructure in 2050 by a scenario study

    NARCIS (Netherlands)

    Weidenaar, Teade; Bekkering, E.; Jauregui Becker, Juan Manuel; Hoekstra, Sipke; Wolters, Mannes

    2013-01-01

    In the changing Dutch energy market, the ageing gas distribution grid needs investments. There is, however, a large uncertainty regarding certain aspects that affect the future role of this gas distribution grid, such as the eventual share of biomethane in the gas mix, whether power-to-gas will

  18. Characterization of industrial waste from a natural gas distribution company and management strategies: a case study of the East Azerbaijan Gas Company (Iran).

    Science.gov (United States)

    Taghipour, Hassan; Aslhashemi, Ahmad; Assadi, Mohammad; Khodaei, Firoz; Mardangahi, Baharak; Mosaferi, Mohammad; Roshani, Babak

    2012-10-01

    Although a fundamental prerequisite for the successful implementation of any waste management plan is the availability of sufficient and accurate data, there are few available studies regarding the characterization and management of gas distribution company waste (GDCW). This study aimed to characterize the industrial waste generated by the East Azerbaijan Gas Distribution Company (EAGDC) and to present environmental management strategies. The EAGDC serves 57 cities and 821 villages with a total population of more than 2.5 million as well as numerous industrial units. The methodology of this study was based on a checklist of data collected from each zone of the company, site visits (observation), and quantity and quality analysis according to the formal data available from different zones. The results indicate that more than 35 different kinds of industrial solid waste are generated in different industrial installations. The most important types of generated waste include empty barrels (including mercaptans, diesel fuel, deionized waters and oil), faulty gas meters and regulators, a variety of industrial oils, sleeves, filter elements and faulty pipes, valves and fittings. The results indicated that, currently, GDCW is generally handled and disposed of with domestic waste, deposited in companies' installation yards and stores or, sometimes, recycled through non-scientific approaches that can create health risks to the public and the environment, even though most of the GDCW was determined to be recyclable or reusable materials. This study concludes that gas distribution companies must pay more attention to source reduction, recycling and reusing of waste to preserve natural resources, landfill space and the environment.

  19. 46 CFR 153.283 - Valving for cargo piping.

    Science.gov (United States)

    2010-10-01

    ... CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Piping Systems and Cargo Handling Equipment § 153.283 Valving for cargo piping. (a) Except as described in this...

  20. Product back-tracing in piping systems made out of polyethylene for the gas supply; Produkte-Rueckverfolgbarkeit in Rohrnetz-Systemen aus Polyethylen fuer die Gasversorgung

    Energy Technology Data Exchange (ETDEWEB)

    Keller, F. [Fischer (G.) AG, Schaffhausen (Switzerland)

    2001-02-01

    Everyone involved in providing piping systems for gas and water supply in particular, is nowadays challenged by a large and various range of demands. Slogans like quality management, product liability, service provider's obligation of due care, cost reduction, profitability of the enterprises involved etc. confront each other at the most diverse and varying angles of juxtaposition. Where it is necessary to reconcile various interests with differing demands, electronic documentation of all data which serves the purpose of back-tracing should be implemented. Now, the new traceability system creates the necessary preconditions for a regularised and reliable system for standardisation, for piping and fitting manufacturers and for the producers of welding equipment. (orig.) [German] Alle Beteiligten, die bei der Erstellung von Rohrnetzen speziell fuer die Gas- und Wasserversorgung involviert sind, werden heute mit den unterschiedlichsten Anforderungen konfrontiert. Schlagworte wie Qualitaetssicherung, Produkthaftung, Sorgfaltspflicht der Dienstleister, Kostenreduktion, Profitabilitaet der beteiligten Unternehmen usw. stehen sich unter den verschiedenen Blickwinkeln gegenueber. Muessen die unterschiedlichen Interessen mit den verschiedenen Anforderungen in Uebereinstimmung gebracht werden, dann sollte eine elektronische Dokumentation aller der Rueckverfolgbarkeit dienenden relevanten Daten realisierbar sein. Auf der Basis des neuen Rueckverfolgbarkeits-Systems sind heute alle Voraussetzungen fuer ein einheitliches und sicheres System seitens der Normung, der Rohr- und Fittinghersteller sowie den Produzenten von Schweissgeraeten verfuegbar. Nun gilt es fuer die Betreiber und Netzverantwortlichen, dieses kostenguenstige Hilfsmittel adaequat und klar strukturiert in Ihren Unternehmungen einzusetzen, um den Anforderungen bezueglich einer durchgehenden Qualitaetssicherung gerecht zu werden. (orig.)

  1. Uniaxial Fatigue of HDPE-100 Pipe. Experimental Analysis

    Directory of Open Access Journals (Sweden)

    A. Aid

    2014-04-01

    Full Text Available In this paper, an experimental analysis for determining the fatigue strength of PE-100, one of the most used High Density Polyethylene (HDPE materials for pipes, under cyclic axial loadings is presented. HDPE is a thermoplastic material used for piping systems, such as natural gas distribution systems, sewer systems and cold water systems, which provides a good alternative to metals such as cast iron or carbon steel. One of the causes for failures of HDPE pipes is fatigue which is the result of pipes being subjected to cyclic loading, such as internal pressure, weight loads or external loadings on buried pipes, which generate stress in different directions: circumferential, longitudinal and radial. HDPE pipes are fabricated using an extrusion process, which generates anisotropic properties. By testing in the Laboratory a series of identical specimens obtained directly from PE-100 HDPE pipes in longitudinal directions, the relationships between amplitude stress and number of cycles (S-N curve test frequency 2 Hz and stress ratio R = 0.0 are established.

  2. Integral gas seal for fuel cell gas distribution assemblies and method of fabrication

    Science.gov (United States)

    Dettling, Charles J.; Terry, Peter L.

    1985-03-19

    A porous gas distribution plate assembly for a fuel cell, such as a bipolar assembly, includes an inner impervious region wherein the bipolar assembly has good surface porosity but no through-plane porosity and wherein electrical conductivity through the impervious region is maintained. A hot-pressing process for forming the bipolar assembly includes placing a layer of thermoplastic sealant material between a pair of porous, electrically conductive plates, applying pressure to the assembly at elevated temperature, and allowing the assembly to cool before removing the pressure whereby the layer of sealant material is melted and diffused into the porous plates to form an impervious bond along a common interface between the plates holding the porous plates together. The distribution of sealant within the pores along the surface of the plates provides an effective barrier at their common interface against through-plane transmission of gas.

  3. Method of fabricating an integral gas seal for fuel cell gas distribution assemblies

    Science.gov (United States)

    Dettling, Charles J.; Terry, Peter L.

    1988-03-22

    A porous gas distribution plate assembly for a fuel cell, such as a bipolar assembly, includes an inner impervious region wherein the bipolar assembly has good surface porosity but no through-plane porosity and wherein electrical conductivity through the impervious region is maintained. A hot-pressing process for forming the bipolar assembly includes placing a layer of thermoplastic sealant material between a pair of porous, electrically conductive plates, applying pressure to the assembly at elevated temperature, and allowing the assembly to cool before removing the pressure whereby the layer of sealant material is melted and diffused into the porous plates to form an impervious bond along a common interface between the plates holding the porous plates together. The distribution of sealant within the pores along the surface of the plates provides an effective barrier at their common interface against through-plane transmission of gas.

  4. 78 FR 34703 - Pipeline Safety: Information Collection Activities, Revision to Gas Distribution Annual Report

    Science.gov (United States)

    2013-06-10

    ... Activities, Revision to Gas Distribution Annual Report AGENCY: Pipeline and Hazardous Materials Safety...) published a notice in the Federal Register of its intent to revise the gas distribution annual report (PHMSA... information collection is titled: ``Annual Report for Gas Distribution Pipeline Operators.'' Summary of Topic...

  5. GeoCEGAS: natural gas distribution management system

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, Lorena C.J. [Companhia de Gas do Ceara (CEGAS), Fortaleza, CE (Brazil); Targa, Fernando O. [Gestao Empresarial e Informatica Ltda. (GEMPI), Sao Paulo, SP (Brazil)

    2009-07-01

    This Technical Paper approach the conception, architecture, design, construction, and implementation of GeoCEGAS, a spatially enabled corporate management information system, oriented to store and provide Web access, to information associated with the natural gas distribution network, owned by CEGAS. This paper reports business processes, business entities and business intelligence approached on the project, as well as an overview of system architecture, applications, and technology used on the implementation of GeoCEGAS. Finally, is presented an introduction to the work methodology used, as well a synopsis of benefits achievements. (author)

  6. Effects of disinfectant and biofilm on the corrosion of cast iron pipes in a reclaimed water distribution system.

    Science.gov (United States)

    Wang, Haibo; Hu, Chun; Hu, Xuexiang; Yang, Min; Qu, Jiuhui

    2012-03-15

    The effects of disinfection and biofilm on the corrosion of cast iron pipe in a model reclaimed water distribution system were studied using annular reactors (ARs). The corrosion scales formed under different conditions were characterized by X-ray diffraction (XRD), energy dispersive spectroscopy (EDS), and scanning electron microscopy (SEM), while the bacterial characteristics of biofilm on the surface were determined using several molecular methods. The corrosion scales from the ARs with chlorine included predominantly α-FeOOH and Fe2O3, while CaPO3(OH)·2H2O and α-FeOOH were the predominant phases after chloramines replaced chlorine. Studies of the consumption of chlorine and iron release indicated that the formation of dense oxide layers and biofilm inhibited iron corrosion, causing stable lower chlorine decay. It was verified that iron-oxidizing bacteria (IOB) such as Sediminibacterium sp., and iron-reducing bacteria (IRB) such as Shewanella sp., synergistically interacted with the corrosion product to prevent further corrosion. For the ARs without disinfection, α-FeOOH was the predominant phase at the primary stage, while CaCO3 and α-FeOOH were predominant with increasing time. The mixed corrosion-inducing bacteria, including the IRB Shewanella sp., the IOB Sediminibacterium sp., and the sulfur-oxidizing bacteria (SOB) Limnobacter thioxidans strain, promoted iron corrosion by synergistic interactions in the primary period, while anaerobic IRB became the predominant corrosion bacteria, preventing further corrosion via the formation of protective layers. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. The spatial distribution of shocked gas in the Orion nebula

    Science.gov (United States)

    Beck, S. C.; Beckwith, S.

    1983-01-01

    Observations of the spatial distribution of extinction and excitation temperature toward the molecular hydrogen emission in the Orion molecular cloud OMC-1 are presented. Most, although not all, of the observed structure in the near-infrared line intensities results from variations in the column density of vibrationally excited H2 and is not due to variable extinction or temperature. The extinction toward the center of the emission region is between 1 and 2 mag at 4712/cm, the frequency of the v = 1-0 S(1) line, but increases toward the edges. The lack of emission from the eastern part of the nebula may result from increased extinction in that direction. Variations in the extinction temperature are less than the observational uncertainties of + or - 200 K at all but one position observed. Therefore, the excitation temperature of the hydrogen molecules is probably not a strong function of either the shock velocity or the density of the gas. Observations of the v = 3-2 S(3) line in the direction of strongest emission indicate the presence of gas temperatures about 2700 K and place constraints on the column density of gas which is at higher temperature.

  8. Distributed Fiber Optic Gas Sensing for Harsh Environment

    Energy Technology Data Exchange (ETDEWEB)

    Juntao Wu

    2008-03-14

    This report summarizes work to develop a novel distributed fiber-optic micro-sensor that is capable of detecting common fossil fuel gases in harsh environments. During the 32-month research and development (R&D) program, GE Global Research successfully synthesized sensing materials using two techniques: sol-gel based fiber surface coating and magnetron sputtering based fiber micro-sensor integration. Palladium nanocrystalline embedded silica matrix material (nc-Pd/Silica), nanocrystalline palladium oxides (nc-PdO{sub x}) and palladium alloy (nc-PdAuN{sub 1}), and nanocrystalline tungsten (nc-WO{sub x}) sensing materials were identified to have high sensitivity and selectivity to hydrogen; while the palladium doped and un-doped nanocrystalline tin oxide (nc-PdSnO{sub 2} and nc-SnO{sub 2}) materials were verified to have high sensitivity and selectivity to carbon monoxide. The fiber micro-sensor comprises an apodized long-period grating in a single-mode fiber, and the fiber grating cladding surface was functionalized by above sensing materials with a typical thickness ranging from a few tens of nanometers to a few hundred nanometers. GE found that the morphologies of such sensing nanomaterials are either nanoparticle film or nanoporous film with a typical size distribution from 5-10 nanometers. nc-PdO{sub x} and alloy sensing materials were found to be highly sensitive to hydrogen gas within the temperature range from ambient to 150 C, while nc-Pd/Silica and nc-WO{sub x} sensing materials were found to be suitable to be operated from 150 C to 500 C for hydrogen gas detection. The palladium doped and un-doped nc-SnO{sub 2} materials also demonstrated sensitivity to carbon monoxide gas at approximately 500 C. The prototyped fiber gas sensing system developed in this R&D program is based on wavelength-division-multiplexing technology in which each fiber sensor is identified according to its transmission spectra features within the guiding mode and cladding modes. The

  9. Promethus Hot Leg Piping Concept

    International Nuclear Information System (INIS)

    AM Girbik; PA Dilorenzo

    2006-01-01

    The Naval Reactors Prime Contractor Team (NRPCT) recommended the development of a gas cooled reactor directly coupled to a Brayton energy conversion system as the Space Nuclear Power Plant (SNPP) for NASA's Project Prometheus. The section of piping between the reactor outlet and turbine inlet, designated as the hot leg piping, required unique design features to allow the use of a nickel superalloy rather than a refractory metal as the pressure boundary. The NRPCT evaluated a variety of hot leg piping concepts for performance relative to SNPP system parameters, manufacturability, material considerations, and comparison to past high temperature gas reactor (HTGR) practice. Manufacturability challenges and the impact of pressure drop and turbine entrance temperature reduction on cycle efficiency were discriminators between the piping concepts. This paper summarizes the NRPCT hot leg piping evaluation, presents the concept recommended, and summarizes developmental issues for the recommended concept

  10. Software for the decision making support on the design of natural gas distribution networks; Software de apoio a decisao para o projeto de rede urbanas de distribuicao de gas natural

    Energy Technology Data Exchange (ETDEWEB)

    Goldbarg, Marco C.; Goldbarg, Elizabeth F.G. [Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil); Campos, Michel F. [PETROBRAS, Rio de Janeiro, RJ (Brazil)

    2004-07-01

    This work presents a computational system to aid the decision making process of installing new networks to distribute natural gas in an urban area. The system is called POM-DIGAS. The purpose of the software is to optimize the design of natural gas distribution networks. The general optimization problem comprises two combinatorial problems. The first one refers to the definition of the network layout. In this problem the objective is to minimize the total length of the network. The second combinatorial problem considers the pipe size optimization in which one must choose the diameters of the pipes regarding the demand requirements. POM-DIGAS is a composite of models and algorithms developed to tackle the two combinatorial problems. Furthermore, the software has a geographic information mode, a tool to automatically acquire several types of data concerning the project and a mode with distinct flow equations in order to allow the utilization of different methodologies for computing the network flows. The system was applied to a case study developed for the city of Natal, Rio Grande do Norte. This work was supported by RedeGasEnergia, FINEP and PETROBRAS. (author)

  11. Wireless Self-powered Visual and NDE Robotic Inspection System for Live Gas Distribution Mains

    Energy Technology Data Exchange (ETDEWEB)

    Susan Burkett; Hagen Schempf

    2006-01-31

    Carnegie Mellon University (CMU) under contract from Department of Energy/National Energy Technology Laboratory (DoE/NETL) and co-funding from the Northeast Gas Association (NGA), has completed the overall system design of the next-generation Explorer-II (X-II) live gas main NDE and visual inspection robot platform. The design is based on the Explorer-I prototype which was built and field-tested under a prior (also DoE- and NGA co-funded) program, and served as the validation that self-powered robots under wireless control could access and navigate live natural gas distribution mains. The X-II system design ({approx}8 ft. and 66 lbs.) was heavily based on the X-I design, yet was substantially expanded to allow the addition of NDE sensor systems (while retaining its visual inspection capability), making it a modular system, and expanding its ability to operate at pressures up to 750 psig (high-pressure and unpiggable steel-pipe distribution mains). A new electronics architecture and on-board software kernel were added to again improve system performance. A locating sonde system was integrated to allow for absolute position-referencing during inspection (coupled with external differential GPS) and emergency-locating. The power system was upgraded to utilize lithium-based battery-cells for an increase in mission-time. The system architecture now relies on a dual set of end camera-modules to house the 32-bit processors (Single-Board Computer or SBC) as well as the imaging and wireless (off-board) and CAN-based (on-board) communication hardware and software systems (as well as the sonde-coil and -electronics). The drive-module (2 ea.) are still responsible for bracing (and centering) to drive in push/pull fashion the robot train into and through the pipes and obstacles. The steering modules and their arrangement, still allow the robot to configure itself to perform any-angle (up to 90 deg) turns in any orientation (incl. vertical), and enable the live launching and

  12. SEALING LARGE-DIAMETER CAST-IRON PIPE JOINTS UNDER LIVE CONDITIONS

    Energy Technology Data Exchange (ETDEWEB)

    Kiran M. Kothari; Gerard T. Pittard

    2005-07-01

    Utilities in the U.S. operate over 75,000 km (47,000 miles) of old cast-iron pipes for gas distribution. Bell-and-spigot joints that connect pipe sections together tend to leak as these pipes age. Current repair practices are costly and highly disruptive. The objective of this program is to design, test and commercialize a robotic system capable of sealing multiple castiron bell and spigot joints from a single pipe entry point. The proposed system will perform repairs with the pipe in service by traveling through the pipe, cleaning each joint surface, and installing a stainless-steel sleeve lined with an epoxy-impregnated felt across the joint. This approach will save considerable time and labor, minimize excavation, avoid traffic disruption, and eliminate any requirement to interrupt service to customers (which would result in enormous expense to utilities). Technical challenges include: (1) repair sleeves must compensate for diametric variation and eccentricity of old cast-iron pipes; (2) the assembly must travel long distances through pipes containing debris; (3) the pipe wall must be effectively cleaned in the immediate area of the joint to assure good bonding of the sleeve; and (4) an innovative bolt-on entry fitting is required to conduct safe repair operations on live mains.

  13. PE 100 pipe systems

    CERN Document Server

    Brömstrup, Heiner

    2012-01-01

    English translation of the 3rd edition ""Rohrsysteme aus PE 100"". Because of the considerably increased performance, pipe and pipe systems made from 100 enlarge the range of applications in the sectors of gas and water supply, sewage disposal, industrial pipeline construction and in the reconstruction and redevelopment of defective pipelines (relining). This book applies in particular to engineers, technicians and foremen working in the fields of supply, disposal and industry. Subject matters of the book are all practice-relevant questions regarding the construction, operation and maintenance

  14. Direct PTV study of powder suspension behind dune in a horizontal circular pipe

    Science.gov (United States)

    Yonezawa, Norio; Oishi, Yoshihiko; Tasaka, Yuji; Murai, Yuichi

    2014-04-01

    As small solid particles are mixed in gas flow in a horizontal pipe, the particles are sometimes long suspended downstream due to dynamic interaction between two phases in turbulent states. Dunes of such particles are naturally formed at the bottom of the pipe in case of heavy flow rate of particles, and the dunes rather help the particles with suspension further downstream. In this study, PTV has been applied for measurement of such particles floating inside a horizontal pipe behind a synthetic dune. Time-resolved PTV analysis of the particle behavior in the section perpendicular to the mainstream has revealed that long-suspended particles keep floating with fountain like convection pattern inside the circular pipe, which consists of ascending flow at the center of the pipe, bouncing flow at the wall, and downwash at the oblique part. The present paper shows their dynamic statistics of the particle behavior for the cross-sectional distributions of concentration, velocity vector, and acceleration vector.

  15. Influence of physical aging on impact embrittlement of uPVC pipes

    OpenAIRE

    Visser, Roy; Bor, Teunis Cornelis; Wolters, Mannes; Warnet, Laurent; Govaert, L.E.

    2011-01-01

    Most failures of unplasticised poly(vinyl chloride) (uPVC) pipes used in the Dutch gas distribution network originate from third party damage. Brittle pipes should therefore be replaced to ensure safe operation of the network. In this study, the relation between physical aging and embrittlement of uPVC is investigated using instrumented falling weight impact tests. The ductile to brittle transition temperature was first measured for a water pipe grade uPVC at different stages of aging. As a h...

  16. Distribution of heavy metals from flue gas in algal bioreactor

    Science.gov (United States)

    Napan, Katerine

    Flue gas from coal-fired power plants is a major source of CO2 to the atmosphere. Microalgae can use this enriched form of CO2 as carbon source and in turn the biomass can be used to produce food, feed, fertilizer and biofuels. However, along with CO2, coal-based flue gas will inevitably introduce heavy metals, which have a high affinity to bind algal cells, could be toxic to the organisms and if transferred to the products could limit their uses. This study seeks to address the distribution and impact of heavy metals present in flue gas on microalgae production systems. To comprehend its effects, algae Scenedesmus obliquus was grown in batch reactors in a multimetal system. Ten heavy metals (Cu, Co, Zn, Pb, As, Se, Cr, Hg, Ni and Cd) were selected and were evaluated at four concentrations (1X, 2X, 5X and 10X). Results show that most heavy metals accumulated mainly in biomass and were found in very low concentrations in media. Hg was shown to be lost from the culture, with low amounts present in the biomass. An upper limit for As uptake was observed, suggesting its likelihood to build-up in the system during medium recycle. The As limited bioaccumulation was overcome by addition of sulfur to the algal medium. Heavy metal at 2X, 5X and 10X inhibited both growth and lipid production, while at the reference concentration both biomass and lipids yields were increased. Heavy metal concentrations in the medium and biomass were time dependent, and at the end of the cultivation most heavy metals in the supernatant solution complied with the recommendations for irrigation water, while biomass was below limits for cattle and poultry feed, fertilizer, plastic and paper. This research shows that bioremediation of CO2 and heavy metals in combination with energy production can be integrated, which is an environmentally friendly form of biotechnology.

  17. 75 FR 51032 - National Fuel Gas Distribution Corporation; Notice of Baseline Filing

    Science.gov (United States)

    2010-08-18

    ... Energy Regulatory Commission National Fuel Gas Distribution Corporation; Notice of Baseline Filing August 12, 2010. Take notice that on August 10, 2010, National fuel Gas Distribution Corporation submitted a... Natural Gas Policy Act of 1978 (``NGPA''). Any person desiring to participate in this rate proceeding must...

  18. The duration of the transitory period of public gas distribution

    International Nuclear Information System (INIS)

    Gazzola, D.

    2006-01-01

    The article describes the interpretative problems concerning the duration of the transitory period of public gas distribution after law decree 273/05 came into effect. This decree is the third legislative measure which, in a period of five years, reforms the transitory provisions. The article outlines the normative background of legislative decree n. 164/00 (so called Letta decree) and law n. 239/04 (so called Marzano law) and it analyses their judicial interpretations. It then explains the changes introduced by law decree n. 273/05 and the new interpretative problems there might be with reference to this decree. The decree clarifies the due date of the transitory period and specifies that the date of 31st December 2005 is postponed to 31st December 2007. The Administrative Tribunal of Lombardia Region Brescia tried to limit the effects of law decree n. 273/05, stating that the new expiration date could not regard the contracts for which the local authorities had already acknowledged the previous due date. The State Council argued instead that the new law decree regards all the contracts. This decree also clarifies that the chances of increasing duration ex art. 15, comma 7, legislative decree n. 164/00, applies automatically, but it doesn't solve the interpretative problem concerning the possibility of adding up more than one of these chances. The article focuses on the problems of the public gas distribution after the reform of this sector with the implementation of directive n. 98/30/CE and it underlines that the various legislative measures of these years are indicative of the difficulty to allow a gradual transition towards a liberalized market. In this context, law decree n. 273/05 is the last legislative measure which tries to guarantee a balance between the rapid liberalization of the market, on one hand, and the interests of the firms which had contracts when the reform came into effect, on the other hand [it

  19. The impact analysis of the connecting pipe length and diameter on the operation of a piston hybrid power machine of positive displacement with gas suction capacity

    Science.gov (United States)

    Shcherba, V. E.; Grigoriev, A. V.; Averyanov, G. S.; Surikov, V. I.; Vedruchenko, V. P.; Galdin, N. S.; Trukhanova, D. A.

    2017-08-01

    The article analyzes the impact of the connecting liquid pipe length and diameter on consumables and power characteristics of the piston hybrid power machine with gas suction capacity. The following operating characteristics of the machine were constructed and analyzed: the average height of the liquid column in the jacket space; instantaneous velocity and height of the liquid column in the jacket space; the relative height of the liquid column in the jacket space; volumetric efficiency; indicator isothermal efficiency; flowrate in the pump section; relative pressure losses during suction; relative flowrate. The dependence of the instantaneous pressure in the work space and the suction space of the compressor section on the rotation angle of the crankshaft is determined for different values of the length and diameter of the connecting pipeline.

  20. Forms of contractual documents for public gas distribution; Modeles de documents contractuels pour la distribution publique de gaz

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-12-01

    This document is a compilation of standard forms of concession agreements and of specifications for public gas distribution (general dispositions, granted network and works, connection to the granted network, gas quality, contracts and conditions of supply, gas prices, concession end and control, various dispositions, agreement between the town and the grantee, calculation of profit rate, gas retail prices, general conditions of supply). (J.S.)

  1. A study on the concentration of CO by the length and the variation of the bent tube of the exhaust pipe for a household gas boiler

    International Nuclear Information System (INIS)

    Leem, Sa Hwan; Huh, Yong Jeong; Lee, Jong Rark

    2008-01-01

    Energy and environment become increasingly serious after the industrial revolution. The demand for gas as an ecofriendly energy source is also increasing. With the demand, the installation and the use of gas boilers have also increased, so the damage to human life by the waste gas (CO and CO 2 ) continues increasing every year. Hence, the aim of this study was to investigate the concentration of CO (Carbon Monoxide) by the length and the variation of the bent tube of the exhaust pipe by installing a boiler with the same method as a household boiler and to discover the harm to humans. For the effect of the length, the allowable concentration of CO is 50ppm, and the 3m of the once bent tube starts exceeding the allowable concentration of CO after 5 minutes, and the 4m and 5m starts exceeding after 3 minutes. In addition, the 1m of three times bent tube starts exceeding the allowable concentration of CO after 3 minutes

  2. Heat pipes

    CERN Document Server

    Dunn, Peter D

    1994-01-01

    It is approximately 10 years since the Third Edition of Heat Pipes was published and the text is now established as the standard work on the subject. This new edition has been extensively updated, with revisions to most chapters. The introduction of new working fluids and extended life test data have been taken into account in chapter 3. A number of new types of heat pipes have become popular, and others have proved less effective. This is reflected in the contents of chapter 5. Heat pipes are employed in a wide range of applications, including electronics cooling, diecasting and injection mo

  3. Neutron radiographic detection limits of fluids in metal pipes

    International Nuclear Information System (INIS)

    Winn, W.G.

    1976-01-01

    Routine maintenance of process pipes at the Savannah River Plant has indicated that undesirable fluids can build up in the various gas lines. Thermal neutron radiography has been used to image thin films of various fluids in thick-walled high-pressure process pipes. A 3.5 x 10 6 n/(cm 2 -sec) thermal neutron beam and standard transfer imaging techniques were used to provide radiographs of the fluid-bearing pipes. In addition, a computer graphics procedure was developed that simulated the neutron radiographs; this method permitted examination of some fluid-pipe configurations not studied experimentally. Actual pipe dimensions ranged in OD from 1 / 4 to 9 / 16 in. with OD/ID = 3. Many common industrial fluids such as H 2 O, oils, and CCl 4 may be detected in thick-walled process pipes, even when distributed in thin (3 to 10 mil) fluid films. By contrast, fluids with a low thermal neutron cross section (D 2 O and T 2 O) can be detected only for much thicker films

  4. 46 CFR 108.449 - Piping tests.

    Science.gov (United States)

    2010-10-01

    ... piping installation. (b) When tested with CO2 or other inert gas under a pressure of 70 kilograms per square centimeter (1000 pounds per square inch), with no additional gas introduced into the system, the leakage in the piping from the cylinders to the stop valves in the manifold must not allow a pressure drop...

  5. 46 CFR 95.15-15 - Piping.

    Science.gov (United States)

    2010-10-01

    ...) Installation test requirements are: (1) Upon completion of the piping installation, and before the cylinders... other inert gas shall be used for this test. (2) The piping from the cylinders to the stop valves in the manifold shall be subjected to a pressure of 1,000 pounds per square inch. With no additional gas being...

  6. 46 CFR 193.15-15 - Piping.

    Science.gov (United States)

    2010-10-01

    ...) Installation test requirements are: (1) Upon completion of the piping installation, and before the cylinders... other inert gas shall be used for this test. (2) The piping from the cylinders to the stop valves in the manifold shall be subjected to a pressure of 1,000 pounds per square inch. With no additional gas being...

  7. Residual stress measurement of large scaled welded pipe using neutron diffraction method. Effect of SCC crack propagation and repair weld on residual stress distribution

    International Nuclear Information System (INIS)

    Suzuki, Hiroshi; Katsuyama, Jinya; Tobita, Tohru; Morii, Yukio

    2011-01-01

    The RESA-1 neutron engineering diffractometer in the JRR-3 (Japan Research Reactor No.3) at the Japan Atomic Energy Agency, which is used for stress measurements, was upgraded to realize residual stress measurements of large scaled mechanical components. A series of residual stress measurements was made to obtain through-thickness residual stress distributions in a Type 304 stainless steel butt-welded pipe of 500A-sch.80 using the upgraded RESA-1 diffractometer. We evaluated effects of crack propagation such as stress corrosion cracking (SCC) and a part-circumference repair weld on the residual stress distributions induced by girth welding. Measured residual stress distributions near original girth weld revealed good agreement with typical results shown in some previous works using finite element method, deep hole drilling as well as neutron diffraction. After introducing a mock crack with 10 mm depth in the heat affected zone on the inside wall of the pipe by electro discharge machining, the axial residual stresses were found to be released in the part of the mock crack. However, changes in the through-wall bending stress component and the self-equilibrated stress component were negligible and hence the axial residual stress distribution in the ligament was remained in the original residual stresses near girth weld without the mock crack. Furthermore, changes in hoop and radial residual stress were also small. The residual stress distributions after a part repair welding on the outer circumference of the girth weld were significantly different from residual stress distributions near the original girth weld. The through-thickness average axial residual stress was increased due to increase of the tensile membrane stress and mitigation of the bending stress after repair welding. Throughout above studies, we evidenced that the neutron diffraction technique is useful and powerful tool for measuring residual stress distributions in large as well as thick mechanical

  8. Pipe locator for imaging underground pipelines (abstract)

    Science.gov (United States)

    Miyamoto, Y.; Wasa, Y.; Mori, K.; Kondo, Y.

    1988-11-01

    Recently, it becomes more important to locate the complex piping patterns such as tee, bend, riser, and the others with high accuracy for maintenance and protection of city gas pipelines. Hence, we have developed a new pipe locator system for imaging the complex underground pipelines using magnetic remote sensing techniques. The main framework of this development is the application of the pattern recognition of the magnetic field distribution to the location of buried pipelines in urban areas. The first step for imaging the complex pipelines is to measure the three-dimensional magnetic field distribution with high accuracy which is generated by the passage of the alternating signal current through buried pipeline. For this purpose a portable trolley unit which is capable of scanning the ground to collect data, the 10 three-axes coil sensors with a sensitivity of 1 μG which are aligned in the unit, and a filter system using a FFT signal processor which eliminates urban magnetic noise as high as 10 mG in some cases, were developed. The second step is to process the magnetic field distribution data, to extract the feature of the underground pipeline using the contour diagram and the three-dimensional drawing of the magnetic field, and to identify the complex piping patterns. Further, we recognized that a nonlinear least-square method algorithm for calculation of the pipeline's position was useful to improve the location accuracy.

  9. Dust and gas distribution in molecular clouds: an observational approach

    International Nuclear Information System (INIS)

    Campeggio, Loretta; Elia, Davide; Maiolo, Berlinda M T; Strafella, Francesco; Cecchi-Pestellini, Cesare

    2005-01-01

    The interstellar medium (ISM), gas and dust, appears to be arranged in clouds, whose dimensions, masses and densities span a large range of scales: from giant molecular clouds to small isolated globules. The structure of these objects show a high degree of complexity appearing, in the range of the observed scales, as a non-homogeneous ('clumpy') distribution of matter. The arrangement of the ISM is clearly relevant for the study of the fragmentation of the clouds and then of the star formation processes. To quantify observationally the ISM structure, many methods have been developed and our study is focused on some of them, exploiting multiwavelength observations of IS objects. The investigations presented here have been carried out by considering both the dust absorption (in optical and near IR wavelengths) and the gas emission (in the submm-radio spectral range). We present the maps obtained from the reduction of raw data and a first tentative analysis by means of methods as the structure function, the autocorrelation, and the Δ-variance. These are appropriate tools to highlight the complex structure of the ISM with reference to the paradigm given by the supersonic turbulence. Three observational cases are briefly discussed. In order to analyse the structure of objects characterized by different sizes, we applied the above-mentioned algorithms to the extinction map of the dark globule CB 107 and to the CO(J = 1-0) integrated intensity map of Vela Molecular Ridge, D Cloud. Finally we compare the results obtained with synthetic fractal maps known as 'fractional Brownian motion' fBm images

  10. Pipe grabber

    Energy Technology Data Exchange (ETDEWEB)

    Sharafutdinov, I.G.; Mubashirov, S.G.; Prokopov, O.I.

    1981-05-15

    A pipe grabber is suggested which contains a housing, clamping elements and centering mechanism with drive installed on the lower end of the housing. In order to improve the reliable operation of the pipe grabber, the centering mechanism is made in the form of a reinforced ringed flexible shaft, while the drive is made in the form of elastic rotating discs. In this case the direction of rotation of the discs and the flexible shaft is the opposite.

  11. Logistical management system for natural gas distribution; Sistema de gestao logistica para a distribuicao de gas natural

    Energy Technology Data Exchange (ETDEWEB)

    Arruda, Joao Bosco F.; Nobre Junior, Ernesto F.; Praca, Eduardo R. [Universidade Federal do Ceara (UFC), Fortaleza, CE (Brazil). Nucleo de Pesquisa em Logistica, Transportes e Desenvolvimento

    2004-07-01

    The Brazilian Federal Government has the very purpose of increasing the participation of the Natural Gas in the primary energy internal supply from 7,5% nowadays to about 12% till 2010. However, for that, it is necessary to eliminate the great impedance represented by the restricted accessibility to the product, due to the high distribution costs involved. So, there is an urgent need for availability of technologies to help natural gas distribution systems. This paper proposes an innovative logistics-based approach on the subject of the natural gas distribution, through a computational tool (GASLOG System) to be applied in the North and Northeastern urban and country areas of Brazil, with initial case study in the city of Fortaleza. In its conception, the GASLOG System focuses on the point-of-view of everyone of the actors involved with the natural gas distribution process trying to respond their particular necessities in the sector. (author)

  12. 46 CFR 153.292 - Separation of piping systems.

    Science.gov (United States)

    2010-10-01

    ... CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Piping Systems and Cargo Handling Equipment § 153.292 Separation of piping systems. Cargo piping systems must be arranged so that operations necessary to provide separate systems can be accomplished in a cargo handling...

  13. Fusion of two electromagnetic field sensor technologies for application to the location of buried gas pipes. Annual report No. 1, July 1, 1994-June 30, 1995

    Energy Technology Data Exchange (ETDEWEB)

    Tranbarger, O.; Fisher, J.L.; Beissner, R.E.; Zook, B.J.

    1995-07-31

    This report describes work accomplished in the first year of a project to develop a practical pipe locator tool for both plastic and metal pipe. Efforts in the first year focused on showing separately the feasibility of both the GPR and Eddy current (EC) technologies to locate pipes. The ground-penetrating radar (GPR) used for demonstration of feasibility was an FM-CW radar system operating the VHF and UHF ranges. In moderate-loss soils, images were produced on 4-inch polyethylene (PE) pipe down to three feet; 2-in PE pipe could be imaged to a depth of two feet. With the EC technology, the edges of backfilled pipe trenches are detectable, and plastic pipes could be detected at shallow depths in high conductivity soils.

  14. Geochemical constraints on the distribution of gas hydrates in the Gulf of Mexico

    Science.gov (United States)

    Paull, C.K.; Ussler, W.; Lorenson, T.; Winters, W.; Dougherty, J.

    2005-01-01

    Gas hydrates are common within near-seafloor sediments immediately surrounding fluid and gas venting sites on the continental slope of the northern Gulf of Mexico. However, the distribution of gas hydrates within sediments away from the vents is poorly documented, yet critical for gas hydrate assessments. Porewater chloride and sulfate concentrations, hydrocarbon gas compositions, and geothermal gradients obtained during a porewater geochemical survey of the northern Gulf of Mexico suggest that the lack of bottom simulating reflectors in gas-rich areas of the gulf may be the consequence of elevated porewater salinity, geothermal gradients, and microbial gas compositions in sediments away from fault conduits. 

  15. [Method of infrared spectrum on-line pattern recognition of mixed gas distribution based on SVM].

    Science.gov (United States)

    Bai, Peng; Ji, Juan-zao; Zhang, Fa-qi; Li, Yan; Liu, Jun-hua; Zhu, Chang-chun

    2008-10-01

    In order to solve the difficulties that the spectrum training data samples of the massive mixed gas cannot be actually obtained, the analysis precision is low and it is not real time online analysis in the analysis of mixed gas component concentration, the support vector machine, a new information processing method, was used in the mixed gas infrared spectrum analysis, and the concept of mixed gas distribution pattern was proposed in the present paper. Based on the thought that the mixed gas distribution pattern recognition is carried out first, and then the analysis work of mixed gas component concentration is done, sixty kinds of mixed gas distribution pattern were determined after investigation and study, and 6000 mixed gas spectrum data samples were used for model training and testing. Sequential minimal optimization algorithm was applied to realize the decrement and the increase of online learning, and finally the model of infrared spectrum online pattern recognition of mixed gas distribution based on SVM was established. The model structure is composed of 2 levels, pattern recognition level and result output level. The pattern recognition level completes the task of mixed gas distribution pattern recognition; while the result output level is composed of 60 SVM calibration models, and it completes the task of mixed gas concentration analysis. Experimental results show that the correct recognition rate of mixture gas distribution pattern is not lower than 98.8%, and that the method can be used for online recognition of mixed gas distribution pattern under the conditions of small samples of a mixed gas, and can add new mixed gas online, and it has the practical application value.

  16. Distributed and decentralized state estimation in gas networks as distributed parameter systems.

    Science.gov (United States)

    Ahmadian Behrooz, Hesam; Boozarjomehry, R Bozorgmehry

    2015-09-01

    In this paper, a framework for distributed and decentralized state estimation in high-pressure and long-distance gas transmission networks (GTNs) is proposed. The non-isothermal model of the plant including mass, momentum and energy balance equations are used to simulate the dynamic behavior. Due to several disadvantages of implementing a centralized Kalman filter for large-scale systems, the continuous/discrete form of extended Kalman filter for distributed and decentralized estimation (DDE) has been extended for these systems. Accordingly, the global model is decomposed into several subsystems, called local models. Some heuristic rules are suggested for system decomposition in gas pipeline networks. In the construction of local models, due to the existence of common states and interconnections among the subsystems, the assimilation and prediction steps of the Kalman filter are modified to take the overlapping and external states into account. However, dynamic Riccati equation for each subsystem is constructed based on the local model, which introduces a maximum error of 5% in the estimated standard deviation of the states in the benchmarks studied in this paper. The performance of the proposed methodology has been shown based on the comparison of its accuracy and computational demands against their counterparts in centralized Kalman filter for two viable benchmarks. In a real life network, it is shown that while the accuracy is not significantly decreased, the real-time factor of the state estimation is increased by a factor of 10. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.

  17. Pulsating Heat Pipes, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Large radiator panels, based upon state of the art conventional heat pipes with attached fins for thermal load distribution and dissipation is the current baseline...

  18. Diffusion in flexible pipes

    Energy Technology Data Exchange (ETDEWEB)

    Brogaard Kristensen, S.

    2000-06-01

    This report describes the work done on modelling and simulation of the complex diffusion of gas through the wall of a flexible pipe. The diffusion and thus the pressure in annulus depends strongly on the diffusion and solubility parameters of the gas-polymer system and on the degree of blocking of the outer surface of the inner liner due to pressure reinforcements. The report evaluates the basis modelling required to describe the complex geometries and flow patterns. Qualitatively results of temperature and concentration profiles are shown in the report. For the program to serve any modelling purpose in 'real life' the results need to be validated and possibly the model needs corrections. Hopefully, a full-scale test of a flexible pipe will provide the required temperatures and pressures in annulus to validate the models. (EHS)

  19. Optical aberrations in a gas lenses

    CSIR Research Space (South Africa)

    Mafusire, C

    2010-08-01

    Full Text Available Gas lenses work on the basis that aerodynamic media can be used to generate a graded refractive index distribution which can be used to focus a laser beam. Examples of these are the spinning pipe gas lens (SPGL) and the flame lens (FL). The SPGL...

  20. Natural gas distribution in Brazil - opportunities of improvement; Distribuicao de gas natural no pais - oportunidades de melhoria

    Energy Technology Data Exchange (ETDEWEB)

    Correa, Silvia R. [PETROBRAS, Rio de Janeiro, RJ (Brazil); Quintella, Odair M.; Farias Filho, Jose R. de [Universidade Federal Fluminense, Niteroi, RJ (Brazil)

    2005-07-01

    Great are the challenges established by the Brazilian Government related to goals to be achieved for the increment of the Natural Gas participation in brazilian energetic matrix, from current 5% to 12%, up to 2010. The enlargement of the distribution infrastructure of the gas (gas-pipelines 'mesh') in Brazil is considered one of the greatest challenges for the growth of the Brazilian market of Natural Gas, accomplishment that involves elevated investments. This paper presents a model of Management System for the good organizational performance of the small Natural Gas Supplying Brazilian Companies focused on criteria of Leadership, Strategies and Plans and Results, established by the Premio TOP Empresarial and by the 'Rumo a Excelencia', held by the 'Progama Qualidade Rio' and 'Fundacao para o Premio Nacional da Qualidade', respectively. The management practices of these companies were reviewed, considering the context of the energetic Brazilian scenario, subjected to the political and operational definitions and uncertainties, the available financial resources, limited or not prioritized, and actual barriers to be surpassed by the Gas Supplying Companies in order to achieve the pre-established government goals for this segment. The implementation of the proposed simplified Model, seen as improvement opportunities for the segment of Natural Gas distribution, will lead the Gas Distribution Companies to a intermediary stage envisioning the real steps towards the excellence of the performance. (author)

  1. Greenhouse Gas Abatement with Distributed Generation in California's Commercial Buildings

    International Nuclear Information System (INIS)

    Stadler, Michael; Marnay, Chris; Cardoso, Goncalo; Megel, Olivier; Siddiqui, Afzal; Lai, Judy

    2009-01-01

    Lawrence Berkeley National Laboratory (LBL) is working with the California Energy Commission (CEC) to determine the role of distributed generation (DG) in greenhouse gas reductions. The impact of DG on large industrial sites is well known, and mostly, the potentials are already harvested. In contrast, little is known about the impact of DG on commercial buildings with peak electric loads ranging from 100 kW to 5 MW. We examine how DG with combined heat and power (CHP) may be implemented within the context of a cost minimizing microgrid that is able to adopt and operate various smart energy technologies, such as thermal and photovoltaic (PV) on-site generation, heat exchangers, solar thermal collectors, absorption chillers, and storage systems. We use a mixed-integer linear program (MILP) that has the minimization of a site's annual energy costs as objective. Using 138 representative commercial sites in California (CA) with existing tariff rates and technology data, we find the greenhouse gas reduction potential for California's commercial sector. This paper shows results from the ongoing research project and finished work from a two year U.S. Department of Energy research project. To show the impact of the different technologies on CO2 emissions, several sensitivity runs for different climate zones within CA with different technology performance expectations for 2020 were performed. The considered sites can contribute between 1 Mt/a and 1.8 Mt/a to the California Air Resources Board (CARB) goal of 6.7Mt/a CO2 abatement potential in 2020. Also, with lower PV and storage costs as well as consideration of a CO2 pricing scheme, our results indicate that PV and electric storage adoption can compete rather than supplement each other when the tariff structure and costs of electricity supply have been taken into consideration. To satisfy the site's objective of minimizing energy costs, the batteries will be charged also by CHP systems during off-peak and mid-peak hours and

  2. An algorithm for testing of gas distribution phases in the internal combustion engines

    Directory of Open Access Journals (Sweden)

    T. Nicu

    1999-10-01

    Full Text Available A method and algorithm for testing the gas distribution phases of internal combustion engines are proposed. This method allows a way of testing the gas distribution phases, based on direct and continuous measurements of pressure in cylinders and negative pressure in the intake manifold for using in the real time.

  3. 78 FR 13661 - National Fuel Gas Distribution Corporation; Notice of Petition for Rate Approval

    Science.gov (United States)

    2013-02-28

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF ENERGY Federal Energy Regulatory Commission National Fuel Gas Distribution Corporation; Notice of Petition for Rate Approval Take notice that on February 12, 2013, National Fuel Gas Distribution Corporation filed for...

  4. Dose distribution effect on optimal geometry for industrial flue gas treatment system

    International Nuclear Information System (INIS)

    Chmielewski, A.G.; Dobrowolski, A.; Tyminski, B.

    1998-01-01

    Dose distribution in a flue gas irradiation vessel is not uniform due to the absorption of electron energy in the gas phase. This phenomenon influences the overall NO x removal efficiency. The remarkable increase in the NO x removal efficiency can be achieved by a multistage gas irradiation system and location of accelerators which enables improvement of dose distribution uniformity in the process vessel. These problems are analysed in this report. (author)

  5. Field test of hydrogen in the natural gas grid

    Energy Technology Data Exchange (ETDEWEB)

    Iskov, H.

    2010-08-15

    In order to prepare for a future use of hydrogen as a fuel gas it became evident that very little information existed regarding the compatibility between long-term exposure and transportation of hydrogen in natural gas pipelines. A program was therefore set to study the transportation in a small-scale pilot grid at the research centre in Hoersholm, Denmark. The test program included steel pipes from the Danish gas transmission grid and polymer pipes from the Danish and Swedish gas distribution grid. The test of polymer pipes was devised so that samples of all test pipes were cut out of the grid each year and analysis performed on these pipe samples; in this way any form of influence on the integrity of the polyethylene pipe would be detected. The analytical program for polymer was devised in order to detect any influence on the additivation of the polyethylene as this has an influence on oxidative resistance, as well as checking already encountered possible degradation caused by extrusion of the material. Further tools as rheology and melt flow rate were used for detecting any structural changes on the material. On the mechanical property side the tensile strength and modulus were followed as well as the most important property for the pipe line, namely slow crack growth. The results of the polymer pipe tests show no degradations of any kind related to the continuous hydrogen exposure for more than 4 years. This is a strong indication of the compatibility to hydrogen of the tested polymer materials PE 80 and PE 100. The object of the steel pipe test was to see the effect on fatigue life of existing natural gas transmission lines with hydrogen replacing the natural gas. Full-scale dynamic tests were performed using randomly selected cut-out API 5L X70 pipe sections with a diameter of 20 inches and a wall thickness of 7 millimetres from the Danish natural gas transmission system. The pipe sections contained field girth weld made during the installation of the pipe

  6. The distribution of warm ionized gas in NGC 891

    Science.gov (United States)

    Rand, Richard J.; Kulkarni, Shrinivas R.; Hester, J. Jeff

    1990-01-01

    Narrow-band imaging is presented of the edge-on spiral NGC 891 in the H-alpha and S II 6716, 6731 A forbidden lines. Emission from H II regions confined to the plane of the galaxy and from diffuse gas up to about 4 kpc off the plane is readily detected. The full radial extent of the diffuse emission in the plane is about 30 kpc. NGC 891 is found to have a surface density of diffuse ionized gas twice the Galactic value, a thicker ionized gas layer, and a larger surface density of ionized gas relative to neutral gas. These are interpreted as consequences of a relatively high level of star formation in this galaxy. Other star formation tracers indicate the same conclusion. Many vertical H-alpha filaments, or 'worms,' extending to over 2 kpc off the plane of the galaxy are seen. These worms are interpreted in terms of chimney models for the interstellar media of spirals.

  7. Estimation of current density distribution of PAFC by analysis of cell exhaust gas

    Energy Technology Data Exchange (ETDEWEB)

    Kato, S.; Seya, A. [Fuji Electric Co., Ltd., Ichihara-shi (Japan); Asano, A. [Fuji Electric Corporate, Ltd., Yokosuka-shi (Japan)

    1996-12-31

    To estimate distributions of Current densities, voltages, gas concentrations, etc., in phosphoric acid fuel cell (PAFC) stacks, is very important for getting fuel cells with higher quality. In this work, we leave developed a numerical simulation tool to map out the distribution in a PAFC stack. And especially to Study Current density distribution in the reaction area of the cell, we analyzed gas composition in several positions inside a gas outlet manifold of the PAFC stack. Comparing these measured data with calculated data, the current density distribution in a cell plane calculated by the simulation, was certified.

  8. Use of a GIS-based hybrid artificial neural network to prioritize the order of pipe replacement in a water distribution network.

    Science.gov (United States)

    Ho, Cheng-I; Lin, Min-Der; Lo, Shang-Lien

    2010-07-01

    A methodology based on the integration of a seismic-based artificial neural network (ANN) model and a geographic information system (GIS) to assess water leakage and to prioritize pipeline replacement is developed in this work. Qualified pipeline break-event data derived from the Taiwan Water Corporation Pipeline Leakage Repair Management System were analyzed. "Pipe diameter," "pipe material," and "the number of magnitude-3( + ) earthquakes" were employed as the input factors of ANN, while "the number of monthly breaks" was used for the prediction output. This study is the first attempt to manipulate earthquake data in the break-event ANN prediction model. Spatial distribution of the pipeline break-event data was analyzed and visualized by GIS. Through this, the users can swiftly figure out the hotspots of the leakage areas. A northeastern township in Taiwan, frequently affected by earthquakes, is chosen as the case study. Compared to the traditional processes for determining the priorities of pipeline replacement, the methodology developed is more effective and efficient. Likewise, the methodology can overcome the difficulty of prioritizing pipeline replacement even in situations where the break-event records are unavailable.

  9. Distribution of artifactual gas on post-mortem multidetector computed tomography (MDCT).

    Science.gov (United States)

    Egger, Coraline; Bize, Pierre; Vaucher, Paul; Mosimann, Pascal; Schneider, Benjamin; Dominguez, Alejandro; Meuli, Reto; Mangin, Patrice; Grabherr, Silke

    2012-01-01

    We investigated the incidence and distribution of post-mortem gas detected with multidetector computed tomography (MDCT) to identify factors that could distinguish artifactual gas from cardiac air embolism. MDCT data of 119 cadavers were retrospectively examined. Gas was semiquantitatively assessed in selected blood vessels, organs, and body spaces (82 total sites). Seventy-four of the 119 cadavers displayed gas (62.2%; CI 95% 52.8-70.9), and 56 (75.7%) displayed gas in the heart. Most gas was detected in the hepatic parenchyma (40%), right heart (38% ventricle, 35% atrium), inferior vena cava (30% infrarenally, 26% suprarenally), hepatic veins (26% left, 29% middle, 22% right), and portal spaces (29%). Male cadavers displayed gas more frequently than female cadavers. Gas was detected 5-84 hours after death; therefore, the post-mortem interval could not reliably predict gas distribution (rho = 0.719, p gas in the right heart was associated with aggregated gas bubbles in the hepatic parenchyma (sensitivity = 100%, specificity = 89.7%). In contrast, gas in the left heart (sensitivity = 41.7%, specificity = 100%) or in periumbilical subcutaneous tissues (sensitivity = 50%, specificity = 96.3%) could not predict gas due to putrefaction. This study is the first to show that the appearance of post-mortem gas follows a specific distribution pattern. An association between intracardiac gas and hepatic parenchymal gas could distinguish between post-mortem-generated gas and vital air embolism. We propose that this finding provides a key for diagnosing death due to cardiac air embolism.

  10. Residence time distribution of the gas phase in a mechanically agitated gas-liquid reactor

    NARCIS (Netherlands)

    Thijert, M.P.G.; Oyevaar, M.H.; Kuper, W.J.; Westerterp, K.R.

    1992-01-01

    In this study we present a measuring method and extensive experimental data on the gas phase RTD in a mechanically agitated gas-liquid reactor with standard dimensions over a wide range of superficial gas velocities, agitation rates and agitator sizes. The results are modelled successfully, using

  11. Beam screens for the LHC beam pipes

    CERN Multimedia

    Patrice Loïez

    1997-01-01

    Cross-section of LHC prototype beam pipes showing the beam screens. Slits in the screens allow residual gas molecules to be pumped out and become frozen to the walls of the ultra-cold beam pipe. Beam screens like these have been designed to line the beam pipes, absorbing radiation before it can hit the magnets and warm them up, an effect that would greatly reduce the magnetic field and cause serious damage.

  12. Remedial measures to tame the frost heaves at gas distribution stations in west-east gas pipeline

    Energy Technology Data Exchange (ETDEWEB)

    Deng, Daoming; Gong, Jing [Beijing Key Laboratory of Urban Oil and Gas Distribution Technology, China University of Petroleum (China); Wang, Xiaoping; Li, Kai; Jiang, Yongtao [West-East Gas Pipeline Company (China)

    2010-07-01

    In China, a pipeline running 3900 kilometers from Xinjiang to the Yangtze River Delta area and with a capacity of 12 billion cubic meters of gas annually was put into operation in 2004. Due to subfreezing gas temperatures, the distribution stations have since then suffered from frost heaves. One method to address this issue could be to install gas-fueled heaters, however, that would imply important additional costs as well as problems in acquiring land. The aim of this paper is to present and compare different methods to deal with the frost heaves issue. Soil replacement with a water mitigation technique was found to be the best option based on geotechnical survey, calculations and data; this technique was successfully applied to several distribution stations with different water tables. A frost heaves mitigation method was developed herein and proved to be more cost effective than gas-fueled heaters.

  13. Power-law distributions for a trapped ion interacting with a classical buffer gas.

    Science.gov (United States)

    DeVoe, Ralph G

    2009-02-13

    Classical collisions with an ideal gas generate non-Maxwellian distribution functions for a single ion in a radio frequency ion trap. The distributions have power-law tails whose exponent depends on the ratio of buffer gas to ion mass. This provides a statistical explanation for the previously observed transition from cooling to heating. Monte Carlo results approximate a Tsallis distribution over a wide range of parameters and have ab initio agreement with experiment.

  14. Current distribution measurements inside an electromagnetic plasma gun operated in a gas-puff mode

    OpenAIRE

    Poehlmann, Flavio R.; Cappelli, Mark A.; Rieker, Gregory B.

    2010-01-01

    Measurements are presented of the time-dependent current distribution inside a coaxial electromagnetic plasma gun. The measurements are carried out using an array of six axially distributed dual-Rogowski coils in a balanced circuit configuration. The radial current distributions indicate that operation in the gas-puff mode, i.e., the mode in which the electrode voltage is applied before injection of the gas, results in a stationary ionization front consistent with the presence of a plasma def...

  15. Distribution of gas in the halo of the galaxy

    Science.gov (United States)

    Blades, J. C.; Cowie, L. L.; Morton, D. C.; York, D. G.; Wu, C. C.

    1982-01-01

    Results are presented from a high-resolution, ultraviolet study of interstellar gas situated away from the plane of the Milky Way Galaxy, using the nuclei of Seyfert galaxies Mkn 509 and F9 as background probes. In these directions, low-velocity, galactic gas were detected as well as two extragalactic clouds, one probably associated with the Magellanic Stream and the other with Mkn 509. These data were combined with results from other lines of sight to show that the ultraviolet species extend about 10 kpc from the plane, assuming the high-latitude gas corotates with the galactic disk. Complimentary observations of the optical Ca II and Na I species suggests that these do not extend as far - perhaps 2 to 3 kpc from the plane. Further, the exceedingly complex velocity structure found only in Magellanic Cloud directions suggests that these sight-lines are not typical of high-latitude gas in general.

  16. Small turbines in distributed utility application: Natural gas pressure supply requirements

    Energy Technology Data Exchange (ETDEWEB)

    Goldstein, H.L.

    1996-05-01

    Implementing distributed utility can strengthen the local distribution system and help avoid or delay the expense of upgrading transformers and feeders. The gas turbine-generator set is an attractive option based on its low front-end capital cost, reliable performance at unmanned stations, and environmental performance characteristics. This report assesses gas turbine utilization issues from a perspective of fuel supply pressure requirements and discusses both cost and operational factors. A primary operational consideration for siting gas turbines on the electric distribution system is whether the local gas distribution company can supply gas at the required pressure. Currently available gas turbine engines require gas supply pressures of at least 150 pounds per square inch gauge, more typically, 250 to 350 psig. Few LDCs maintain line pressure in excess of 125 psig. One option for meeting the gas pressure requirements is to upgrade or extend an existing pipeline and connect that pipeline to a high-pressure supply source, such as an interstate transmission line. However, constructing new pipeline is expensive, and the small volume of gas required by the turbine for the application offers little incentive for the LDC to provide this service. Another way to meet gas pressure requirements is to boost the compression of the fuel gas at the gas turbine site. Fuel gas booster compressors are readily available as stand-alone units and can satisfactorily increase the supply pressure to meet the turbine engine requirement. However, the life-cycle costs of this equipment are not inconsequential, and maintenance and reliability issues for boosters in this application are questionable and require further study. These factors may make the gas turbine option a less attractive solution in DU applications than first indicated by just the $/kW capital cost. On the other hand, for some applications other DU technologies, such as photovoltaics, may be the more attractive option.

  17. Flue gas recovery system for natural gas combined heat and power plant with distributed peak-shaving heat pumps

    International Nuclear Information System (INIS)

    Zhao, Xiling; Fu, Lin; Wang, Xiaoyin; Sun, Tao; Wang, Jingyi; Zhang, Shigang

    2017-01-01

    Highlights: • A flue gas recovery system with distributed peak-shaving heat pumps is proposed. • The system can improve network transmission and distribution capacity. • The system is advantageous in energy saving, emission reduction and economic benefits. - Abstract: District heating systems use distributed heat pump peak-shaving technology to adjust heat in secondary networks of substations. This technology simultaneously adjusts the heat of the secondary network and reduces the return-water temperature of the primary network by using the heat pump principle. When optimized, low temperature return-water is able to recycle more waste heat, thereby further improving the heating efficiency of the system. This paper introduces a flue gas recovery system for a natural gas combined heat and power plant with distributed peak-shaving heat pumps. A pilot system comprising a set of two 9F gas-steam combined cycle-back pressure heating units was used to analyse the system configuration and key parameters. The proposed system improved the network transmission and distribution capacity, increased heating capacity, and reduced heating energy consumption without compromising heating safety issues. As such, the proposed system is advantageous in terms of energy saving, emission reduction, and economic benefits.

  18. Determination of gas temperature in the plasmatron channel according to the known distribution of electronic temperature

    Directory of Open Access Journals (Sweden)

    Gerasimov Alexander V.

    2013-01-01

    Full Text Available An analytical method to calculate the temperature distribution of heavy particles in the channel of the plasma torch on the known distribution of the electronic temperature has been proposed. The results can be useful for a number of model calculations in determining the most effective conditions of gas blowing through the plasma torch with the purpose of heating the heavy component. This approach allows us to understand full details about the heating of cold gas, inpouring the plasma, and to estimate correctly the distribution of the gas temperature inside the channel.

  19. Results of the survey among industrialists connected to natural gas distribution networks

    International Nuclear Information System (INIS)

    2004-12-01

    The mission entrusted to the Regulatory Commission of Energy (CRE) is to ensure the transparent and non-discriminatory access to public grids of transmission and distribution of electricity, to transport, distribution or storage of natural gas as well as access to liquefied natural gas facilities. In this framework, CRE launched a survey among industrial companies having sites connected to natural gas distribution networks. With this confidential questionnaire, CRE collected the opinion and experience feedback of these companies about the opening of energy markets. The questionnaire offered also the possibility to companies to propose improvements and recommendations. This document presents the results of this survey carried out in 2004

  20. On the distribution of interstellar gas in the galactic halo

    Science.gov (United States)

    Hobbs, L. M.; Morgan, W. W.; Albert, C. E.; Lockman, F. J.

    1982-01-01

    New and existing observations of 21-cm emission lines toward 10 distant, high-latitude OB stars are combined with existing observations of interstellar Lyman-alpha absorption lines, in order to determine the ratio, N21/N-alpha, of the two different column densities of H I. This ratio, which is related to the fraction of the cool, neutral gas in the halo that lies beyond each star, decreases smoothly to about unity with increasing distance from the galactic plane. The column density of neutral gas beyond about 1 kpc can be as much as one-third of the total above the plane, but only relatively small amounts of such gas lie more than 2 kpc from the plane. The distances to, and the possible birthplaces of, these Population I stars in the halo are discussed.

  1. Shells, holes, worms, high-velocity gas and the z-distribution of gas in galaxies.

    Science.gov (United States)

    Rand, R. J.

    The author gives an overview of the current observational understanding of vertically extended gas components in spiral galaxies and the various phenomena which come under such names as shells, holes, worms, and high-velocity gas. For the most part, the focus is on recent high-resolution interferometric studies. The author concentrates on cold gas, and briefly on warm ionized gas, in the Milky Way and a few nearby spirals. Along the way, it is seen how phenomena such as worms and shells may be related to the formation and maintenance of the vertically extended components.

  2. Just fracking: a distributive environmental justice analysis of unconventional gas development in Pennsylvania, USA

    Science.gov (United States)

    Clough, Emily; Bell, Derek

    2016-02-01

    This letter presents a distributive environmental justice analysis of unconventional gas development in the area of Pennsylvania lying over the Marcellus Shale, the largest shale gas formation in play in the United States. The extraction of shale gas using unconventional wells, which are hydraulically fractured (fracking), has increased dramatically since 2005. As the number of wells has grown, so have concerns about the potential public health effects on nearby communities. These concerns make shale gas development an environmental justice issue. This letter examines whether the hazards associated with proximity to wells and the economic benefits of shale gas production are fairly distributed. We distinguish two types of distributive environmental justice: traditional and benefit sharing. We ask the traditional question: are there a disproportionate number of minority or low-income residents in areas near to unconventional wells in Pennsylvania? However, we extend this analysis in two ways: we examine income distribution and level of education; and we compare before and after shale gas development. This contributes to discussions of benefit sharing by showing how the income distribution of the population has changed. We use a binary dasymetric technique to remap the data from the 2000 US Census and the 2009-2013 American Communities Survey and combine that data with a buffer containment analysis of unconventional wells to compare the characteristics of the population living nearer to unconventional wells with those further away before and after shale gas development. Our analysis indicates that there is no evidence of traditional distributive environmental injustice: there is not a disproportionate number of minority or low-income residents in areas near to unconventional wells. However, our analysis is consistent with the claim that there is benefit sharing distributive environmental injustice: the income distribution of the population nearer to shale gas wells

  3. Measurement of the enrichment of uranium-hexafluoride gas in product pipes in the centrifuge enrichment plant at Almelo

    International Nuclear Information System (INIS)

    Packer, T.W.; Lees, E.W.; Aaldijk, J.K.; Harry, R.J.S.

    1987-09-01

    One of the objectives of safeguarding centrifuge enrichment plants is to apply non-destructive measurements inside the cascade area to confirm that the enrichment level is in the low enriched uranium range. Research in the UK and USA has developed a NDA instrument which can confirm the presence of low enriched uranium on a rapid go/no go basis in cascade header pipework of their centrifuge enrichment plants. The instrument is based on a gamma spectroscopic measurement coupled with an X-ray fluorescence analysis. This report gives the results of measurements carried out at Almelo by the UKAEA Harwell, ECN Petten and KFA Juelich to determine if these techniques could be employed at Almelo and Gronau. The energy dispersive X-ray fluorescence analysis has been applied to determine the total mass of uranium in the gas phase, and the deposit correction technique and the two geometry technique have been applied at Almelo to correct the measured gamma intensities for those emitted by the deposit. After an executive summary the report discusses the principles of the two correction methods. A short description of the equipment precedes the presentation of the results of the measurements and the discussion. After the conclusions the report contains two appendices which contain the derivation of the formulae for the deposit correction technique and a discussion of the systematic errors of this technique. 8 figs.; 11 refs.; 6 tables

  4. Non-Intrusive, Distributed Gas Sensing Technology for Advanced Spacesuits

    Science.gov (United States)

    Delgado, Jesus; Phillips, Straun; Rubtsov, Vladimir; Chullen, Cinda

    2015-01-01

    Chemical sensors for monitoring gas composition, including oxygen, humidity, carbon dioxide, and trace contaminants, are needed to characterize and validate spacesuit design and operating parameters. This paper reports on the first prototypes of a non-intrusive gas sensing technology based on flexible sensitive patches positioned inside spacesuit prototypes and interrogated via optical fibers routed outside the suit, taking advantage of the transparent materials of the suit prototypes. The sensitive patches are based on luminescent materials whose emission parameters vary with the partial pressure of a specific gas. Patches sensitive to carbon dioxide, humidity, and temperature have been developed, and their preliminary laboratory characterization in Mark III-like helmet parts is described. The first prototype system consists of a four-channel fiber optic luminescent detector that can be used to monitor any of the selected target gases at four locations. To switch from one gas to another we replace the (disposable) sensor patches and adjust the system settings. Repeatability among sensitive patches and of sensor performance from location to location has been confirmed, assuring that suit engineers will have flexibility in selecting multiple sensing points, fitting the sensor elements into the spacesuit, and easily repositioning the sensor elements as desired. The evaluation of the first prototype for monitoring carbon dioxide during washout studies in a spacesuit prototype is presented.

  5. Distributed control applied to combined electricity and natural gas infrastructures

    NARCIS (Netherlands)

    Arnold, M.; Negenborn, R.R.; Andersson, G.; De Schutter, B.

    2009-01-01

    The optimization of combined electricity and natural gas systems is addressed in this paper. The two networks are connected via energy hubs. Using the energy hub concept, the interactions between the different infrastructures can be analyzed. A system consisting of several interconnected hubs forms

  6. Velocity distribution of a driven inelastic one-component Maxwell gas.

    Science.gov (United States)

    Prasad, V V; Das, Dibyendu; Sabhapandit, Sanjib; Rajesh, R

    2017-03-01

    The nature of the velocity distribution of a driven granular gas, though well studied, is unknown as to whether it is universal or not, and, if universal, what it is. We determine the tails of the steady state velocity distribution of a driven inelastic Maxwell gas, which is a simple model of a granular gas where the rate of collision between particles is independent of the separation as well as the relative velocity. We show that the steady state velocity distribution is nonuniversal and depends strongly on the nature of driving. The asymptotic behavior of the velocity distribution is shown to be identical to that of a noninteracting model where the collisions between particles are ignored. For diffusive driving, where collisions with the wall are modeled by an additive noise, the tails of the velocity distribution is universal only if the noise distribution decays faster than exponential.

  7. Welfare effects of unbundling gas storage and distribution

    International Nuclear Information System (INIS)

    Breton, M.; Montreal Univ., PQ; Kharbach, M.

    2006-01-01

    The creation of inventories and stockpiles can help to reduce price and production fluctuations. This paper presented the results of a simulation of market architectures using a 2 period model. The aim of the paper was to provide insights on the merits of a gas unbundling policy recently adopted in many gas markets. In terms of market architecture, it was first assumed that one of the gas firms owned the storage facility and was mandated to give a second firm access to it. It was then assumed that an independent third firm was responsible for the storage activity so that the other 2 firms competed in the downstream gas market and bought storage services from the independent firm. High and low price periods in a single year were considered. The first architecture assumed an Open Access framework which introduced a Stackelberg competition component in the downstream market through the storage participation in the final goods offering. The second architecture assumed an independent storage activity, and a Cournot component was present. Seasonal storage facilities were filled during the low price period and emptied during the high price period. Results of the simulation indicated that total welfare and consumer welfare were maximized in the case of the integrated firm owning the storage facilities and operating in the downstream market. Success was attributed to the Open Access framework and the Stackelberg competition component in the downstream market. The bundled architecture led to higher consumer surplus than the unbundled architecture. It was concluded that regulatory reforms in North American and European gas sectors that foster separating storage and merchant activities can not be justified based on welfare arguments. 12 refs., 1 tab

  8. Model documentation: Natural gas transmission and distribution model of the National Energy Modeling System. Volume 1

    International Nuclear Information System (INIS)

    1995-01-01

    The Natural Gas Transmission and Distribution Model (NGTDM) is the component of the National Energy Modeling System (NEMS) that is used to represent the domestic natural gas transmission and distribution system. NEMS was developed in the Office of integrated Analysis and Forecasting of the Energy information Administration (EIA). NEMS is the third in a series of computer-based, midterm energy modeling systems used since 1974 by the EIA and its predecessor, the Federal Energy Administration, to analyze domestic energy-economy markets and develop projections. The NGTDM is the model within the NEMS that represents the transmission, distribution, and pricing of natural gas. The model also includes representations of the end-use demand for natural gas, the production of domestic natural gas, and the availability of natural gas traded on the international market based on information received from other NEMS models. The NGTDM determines the flow of natural gas in an aggregate, domestic pipeline network, connecting domestic and foreign supply regions with 12 demand regions. The methodology employed allows the analysis of impacts of regional capacity constraints in the interstate natural gas pipeline network and the identification of pipeline capacity expansion requirements. There is an explicit representation of core and noncore markets for natural gas transmission and distribution services, and the key components of pipeline tariffs are represented in a pricing algorithm. Natural gas pricing and flow patterns are derived by obtaining a market equilibrium across the three main elements of the natural gas market: the supply element, the demand element, and the transmission and distribution network that links them. The NGTDM consists of four modules: the Annual Flow Module, the Capacity F-expansion Module, the Pipeline Tariff Module, and the Distributor Tariff Module. A model abstract is provided in Appendix A

  9. Model documentation: Natural gas transmission and distribution model of the National Energy Modeling System. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-02-17

    The Natural Gas Transmission and Distribution Model (NGTDM) is the component of the National Energy Modeling System (NEMS) that is used to represent the domestic natural gas transmission and distribution system. NEMS was developed in the Office of integrated Analysis and Forecasting of the Energy information Administration (EIA). NEMS is the third in a series of computer-based, midterm energy modeling systems used since 1974 by the EIA and its predecessor, the Federal Energy Administration, to analyze domestic energy-economy markets and develop projections. The NGTDM is the model within the NEMS that represents the transmission, distribution, and pricing of natural gas. The model also includes representations of the end-use demand for natural gas, the production of domestic natural gas, and the availability of natural gas traded on the international market based on information received from other NEMS models. The NGTDM determines the flow of natural gas in an aggregate, domestic pipeline network, connecting domestic and foreign supply regions with 12 demand regions. The methodology employed allows the analysis of impacts of regional capacity constraints in the interstate natural gas pipeline network and the identification of pipeline capacity expansion requirements. There is an explicit representation of core and noncore markets for natural gas transmission and distribution services, and the key components of pipeline tariffs are represented in a pricing algorithm. Natural gas pricing and flow patterns are derived by obtaining a market equilibrium across the three main elements of the natural gas market: the supply element, the demand element, and the transmission and distribution network that links them. The NGTDM consists of four modules: the Annual Flow Module, the Capacity F-expansion Module, the Pipeline Tariff Module, and the Distributor Tariff Module. A model abstract is provided in Appendix A.

  10. On the whistling of corrugated pipes with narrow cavities

    NARCIS (Netherlands)

    Golliard, J.; Belfroid, S.P.C.; González Diez, N.; Bendiksen, E.; Frimodt, C.

    2013-01-01

    Pipes with a corrugated inner surface, as used inflexible pipes for gas production and transport, can be subject to Flow-Induced Pulsations when the flow velocities are higher than a certain onset velocity. The onset velocity for classical corrugated pipes can be predicted on basis of the geometry

  11. Fugitive methane emissions from leak-prone natural gas distribution infrastructure in urban environments.

    Science.gov (United States)

    Hendrick, Margaret F; Ackley, Robert; Sanaie-Movahed, Bahare; Tang, Xiaojing; Phillips, Nathan G

    2016-06-01

    Fugitive emissions from natural gas systems are the largest anthropogenic source of the greenhouse gas methane (CH4) in the U.S. and contribute to the risk of explosions in urban environments. Here, we report on a survey of CH4 emissions from 100 natural gas leaks in cast iron distribution mains in Metro Boston, MA. Direct measures of CH4 flux from individual leaks ranged from 4.0 - 2.3 × 10(4) g CH4•day(-1). The distribution of leak size is positively skewed, with 7% of leaks contributing 50% of total CH4 emissions measured. We identify parallels in the skewed distribution of leak size found in downstream systems with midstream and upstream stages of the gas process chain. Fixing 'superemitter' leaks will disproportionately stem greenhouse gas emissions. Fifteen percent of leaks surveyed qualified as potentially explosive (Grade 1), and we found no difference in CH4 flux between Grade 1 leaks and all remaining leaks surveyed (p = 0.24). All leaks must be addressed, as even small leaks cannot be disregarded as 'safely leaking.' Key methodological impediments to quantifying and addressing the impacts of leaking natural gas distribution infrastructure involve inconsistencies in the manner in which gas leaks are defined, detected, and classified. To address this need, we propose a two-part leak classification system that reflects both the safety and climatic impacts of natural gas leaks. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. 77 FR 5472 - Pipeline Safety: Expanding the Use of Excess Flow Valves in Gas Distribution Systems to...

    Science.gov (United States)

    2012-02-03

    ...: Expanding the Use of Excess Flow Valves in Gas Distribution Systems to Applications Other Than Single-Family... Safety: Expanding the Use of Excess Flow Valves (EFVs) in Gas Distribution Systems to Applications Other... the use of EFVs in gas distribution systems. On January 10, 2012, PHMSA received a request to extend...

  13. Edge seal for a porous gas distribution plate of a fuel cell

    Science.gov (United States)

    Feigenbaum, Haim; Pudick, Sheldon; Singh, Rajindar

    1984-01-01

    In an improved seal for a gas distribution plate of a fuel cell, a groove is provided extending along an edge of the plate. A member of resinous material is arranged within the groove and a paste comprising an immobilized acid is arranged surrounding the member and substantially filling the groove. The seal, which is impervious to the gas being distributed, is resistant to deterioration by the electrolyte of the cell.

  14. Optimizing Ventilation Distribution and Gas Exchange in Combat-Related Lung Injury Using Multifrequency Oscillation

    Science.gov (United States)

    2017-10-01

    AWARD NUMBER: W81XWH-16-1-0434 TITLE: Optimizing Ventilation Distribution and Gas Exchange in Combat-Related Lung Injury Using Multifrequency...15 Sep 2016 - 14 Sep 2017 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Optimizing Ventilation Distribution and Gas Exchange in Combat-Related Lung...research project was to develop a novel method for mechanical ventilation , termed ‘Multi-Frequency Oscillatory Ventilation ’ (MFOV), which optimizes

  15. Evaluation of clamp effects on LMFBR piping systems

    International Nuclear Information System (INIS)

    Jones, G.L.

    1980-01-01

    Loop-type liquid metal breeder reactor plants utilize thin-wall piping to mitigate through-wall thermal gradients due to rapid thermal transients. These piping loops require a support system to carry the combined weight of the pipe, coolant and insulation and to provide attachments for seismic restraints. The support system examined here utilizes an insulated pipe clamp designed to minimize the stresses induced in the piping. To determine the effect of these clamps on the pipe wall a non-linear, two-dimensional, finite element model of the clamp, insulation and pipe wall was used to determine the clamp/pipe interface load distributions which were then applied to a three-dimensional, finite element model of the pipe. The two-dimensional interaction model was also utilized to estimate the combined clamp/pipe stiffness

  16. Plastic Pipe Failure, Risk, and Threat Analysis

    Science.gov (United States)

    2009-04-29

    The three primary failure modes that may be exhibited by polyethylene (PE) gas pipe materials were described in detail. The modes are: ductile rupture, slow crack growth (SCG), and rapid crack propagation (RCP). Short term mechanical tests were evalu...

  17. Laser-GMA Hybrid Pipe Welding System

    National Research Council Canada - National Science Library

    Reutzel, Edward W; Kern, Ludwig; Sullivan, Michael J; Tressler, Jay F; Avalos, Juan

    2007-01-01

    The combination of laser welding with conventional gas metal arc welding technology offers substantial increases in production rate of joining pipe through single-pass joining compared to multi-pass...

  18. Beyond phthalates: Gas phase concentrations and modeled gas/particle distribution of modern plasticizers

    Energy Technology Data Exchange (ETDEWEB)

    Schossler, Patricia [Fraunhofer WKI, Department of Material Analysis and Indoor Chemistry, Bienroder Weg 54E, D-38108 Braunschweig (Germany); Institute of Environmental and Sustainable Chemistry, Technische Universitaet Braunschweig, Hagenring 30, D-38106 Braunschweig (Germany); Schripp, Tobias, E-mail: tobias.schripp@wki.fraunhofer.de [Fraunhofer WKI, Department of Material Analysis and Indoor Chemistry, Bienroder Weg 54E, D-38108 Braunschweig (Germany); Salthammer, Tunga [Fraunhofer WKI, Department of Material Analysis and Indoor Chemistry, Bienroder Weg 54E, D-38108 Braunschweig (Germany); Bahadir, Muefit [Institute of Environmental and Sustainable Chemistry, Technische Universitaet Braunschweig, Hagenring 30, D-38106 Braunschweig (Germany)

    2011-09-01

    The ongoing health debate about polymer plasticizers based on the esters of phthalic acid, especially di(2-ethylhexyl) phthalate (DEHP), has caused a trend towards using phthalates of lower volatility such as diisononyl phthalate (DINP) and towards other acid esters, such as adipates, terephthalates, citrates, etc. Probably the most important of these so-called 'alternative' plasticizers is diisononyl cyclohexane-1,2-dicarboxylate (DINCH). In the indoor environment, the continuously growing market share of this compound since its launch in 2002 is inter alia apparent from the increasing concentration of DINCH in settled house dust. From the epidemiological point of view there is considerable interest in identifying how semi-volatile organic compounds (SVOCs) distribute in the indoor environment, especially in air, airborne particles and sedimented house dust. This, however, requires reliable experimental concentration data for the different media and good measurements or estimates of their physical and chemical properties. This paper reports on air concentrations for DINP, DINCH, diisobutyl phthalate (DIBP), diisobutyl adipate (DIBA), diisobutyl succinate (DIBS) and diisobutyl glutarate (DIBG) from emission studies in the Field and Laboratory Emission Cell (FLEC). For DINP and DINCH it took about 50 days to reach the steady-state value: for four months no decay in the concentration could be observed. Moreover, vapor pressures p{sub 0} and octanol-air partitioning coefficients K{sub OA} were obtained for 37 phthalate and non-phthalate plasticizers from two different algorithms: EPI Suite and SPARC. It is shown that calculated gas/particle partition coefficients K{sub p} and fractions can widely differ due to the uncertainty in the predicted p{sub 0} and K{sub OA} values. For most of the investigated compounds reliable experimental vapor pressures are not available. Rough estimates can be obtained from the measured emission rate of the pure compound in a

  19. Gas distributor for fluidized bed coal gasifier

    Science.gov (United States)

    Worley, Arthur C.; Zboray, James A.

    1980-01-01

    A gas distributor for distributing high temperature reaction gases to a fluidized bed of coal particles in a coal gasification process. The distributor includes a pipe with a refractory reinforced lining and a plurality of openings in the lining through which gas is fed into the bed. These feed openings have an expanding tapered shape in the downstream or exhaust direction which aids in reducing the velocity of the gas jets as they enter the bed.

  20. Device for extracting steam or gas from the primary coolant line leading from a reactor pressure vessel to a straight through boiler or from the top primary boiler chamber of a water-cooled nuclear reactor

    International Nuclear Information System (INIS)

    Schatz, K.

    1982-01-01

    In such a nuclear reactor, a steam or gas cushion can form when the primary system is refilled, which can cause blocking of the natural circulation or filling of the system in the area of the hot primary coolant pipe or in the top primary boiler chamber. In order to remove such a steam or gas cushion, a ventilation pipe starting from the bend of the primary coolant line is connected to the feed pipe for introducing water into the primary system. The feed pipe is designed on the principle of the vacuum pump in the area of the opening of the ventilation pipe. There is a sub-pressure in the ventilation pipe, which makes it possible to extract the steam or gas. After mixing in the area of the opening, the steam condenses or is distributed with the gas in the primary coolant. (orig.) [de

  1. 46 CFR 34.25-15 - Piping-T/ALL.

    Science.gov (United States)

    2010-10-01

    ... requirements of subchapter F (Marine Engineering) of this chapter. (b) Distribution piping shall be of materials resistant to corrosion, except that steel or iron pipe may be used if inside corrosion resistant...

  2. Portomesenteric venous gas: is gas distribution linked to etiology and outcome?

    Science.gov (United States)

    Heye, Tobias; Bernhard, Michael; Mehrabi, Arianeb; Kauczor, Hans-Ulrich; Hosch, Waldemar

    2012-12-01

    To investigate various anatomical locations of portomesenteric venous gas detected by computed tomography (CT) and their relationship with the underlying etiology and the outcome. The study group consisted of 47 cases with evidence of portomesenteric venous gas detected on abdominal CT examinations, 12 cases were identified through a retrospective PACS search, 35 were prospectively included. The presence of gas at specific anatomical locations in the portomesenteric venous vasculature was assessed according to a pre-defined classification: the arcade vessels close to the bowel segments followed by segmental vessels, the superior mesenteric vein, the extra- and intrahepatic portal vein. The etiology of portomesenteric venous gas and its prognosis were assessed by review of surgical reports, histopathology and medical records. Surgery was performed on 30 patients. Overall 68.1% of cases were of ischemic etiology. Gas present in the arcade vessels was the best indicator for ischemia (sensitivity 93.8%; specificity 70.0%, positive predictive value 90.9%, negative predictive value 77.8%) compared to other locations and the mere presence of portomesenteric gas independent from the location. The overall mortality rate was 53.2%. Only gas in the arcade and segmental vessels were associated with considerably higher mortality rates (65.8% and 75.0%, respectively) and acceptable frequency (occurrence in 80.9% and 59.6%, respectively). The study results indicate that the presence of gas at specific anatomical locations in the portomesenteric venous system, namely the arcade and segmental vessels, may serve as strong indicator for ischemic etiology and poor prognosis in the assessment of individual cases. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  3. Heat pipes

    CERN Document Server

    Dunn, Peter D

    1982-01-01

    A comprehensive, up-to-date coverage of the theory, design and manufacture of heat pipes and their applications. This latest edition has been thoroughly revised, up-dated and expanded to give an in-depth coverage of the new developments in the field. Significant new material has been added to all the chapters and the applications section has been totally rewritten to ensure that topical and important applications are appropriately emphasised. The bibliography has been considerably enlarged to incorporate much valuable new information. Thus readers of the previous edition, which has established

  4. Perturbation of the Maxwellian distribution in chemically reacting gas mixtures

    Science.gov (United States)

    Alekseyev, B. V.; Yanovskiy, V. R.

    1972-01-01

    Chemically reacting gas mixtures are considered for the case in which inelastic collisions occur significantly less frequently than elastic ones. The first approximation of the general solution of the Boltzmann equation is developed and is shown to contain an additional scaler term. The concentration, the mean mass velocity, and the temperature of the mixture are determined and the rate of reaction in the first approximation is formulated. Tables are presented which give reaction rate values obtained by both the first and second approximation for different activation energies. The tables show that the first approximation is sufficient for practical purposes for calculating the reaction rate.

  5. Quasimomentum distribution and expansion of an anyonic gas

    Science.gov (United States)

    Dubček, Tena; Klajn, Bruno; Pezer, Robert; Buljan, Hrvoje; Jukić, Dario

    2018-01-01

    We point out that the momentum distribution is not a proper observable for a system of anyons in two dimensions. In view of anyons as Wilczek's composite charged flux tubes, this is a consequence of the fact that the orthogonal components of the kinetic momentum operator do not commute at the position of a flux tube, and thus cannot be diagonalized in the same basis. As a substitute for the momentum distribution of an anyonic (spatially localized) state, we propose to use the asymptotic single-particle density after the expansion of anyons in free space from the state. This definition is identical to the standard one when the statistical parameter approaches that for bosons or fermions. Exact examples which underpin our proposal are shown. They reveal that the quasimomentum distribution can be used to identify anyonic statistics in standard time-of-flight measurements.

  6. Distributed Control Architecture for Gas Turbine Engine. Chapter 4

    Science.gov (United States)

    Culley, Dennis; Garg, Sanjay

    2009-01-01

    The transformation of engine control systems from centralized to distributed architecture is both necessary and enabling for future aeropropulsion applications. The continued growth of adaptive control applications and the trend to smaller, light weight cores is a counter influence on the weight and volume of control system hardware. A distributed engine control system using high temperature electronics and open systems communications will reverse the growing trend of control system weight ratio to total engine weight and also be a major factor in decreasing overall cost of ownership for aeropropulsion systems. The implementation of distributed engine control is not without significant challenges. There are the needs for high temperature electronics, development of simple, robust communications, and power supply for the on-board electronics.

  7. Explorer-II: Wireless Self-Powered Visual and NDE Robotic Inspection System for Live Gas Distribution Mains

    Energy Technology Data Exchange (ETDEWEB)

    Carnegie Mellon University

    2008-09-30

    Carnegie Mellon University (CMU) under contract from Department of Energy/National Energy Technology Laboratory (DoE/NETL) and co-funding from the Northeast Gas Association (NGA), has completed the overall system design, field-trial and Magnetic Flux Leakage (MFL) sensor evaluation program for the next-generation Explorer-II (X-II) live gas main Non-destructive Evaluation (NDE) and visual inspection robot platform. The design is based on the Explorer-I prototype which was built and field-tested under a prior (also DoE- and NGA co-funded) program, and served as the validation that self-powered robots under wireless control could access and navigate live natural gas distribution mains. The X-II system design ({approx}8 ft. and 66 lbs.) was heavily based on the X-I design, yet was substantially expanded to allow the addition of NDE sensor systems (while retaining its visual inspection capability), making it a modular system, and expanding its ability to operate at pressures up to 750 psig (high-pressure and unpiggable steel-pipe distribution mains). A new electronics architecture and on-board software kernel were added to again improve system performance. A locating sonde system was integrated to allow for absolute position-referencing during inspection (coupled with external differential GPS) and emergency-locating. The power system was upgraded to utilize lithium-based battery-cells for an increase in mission-time. The resulting robot-train system with CAD renderings of the individual modules. The system architecture now relies on a dual set of end camera-modules to house the 32-bit processors (Single-Board Computer or SBC) as well as the imaging and wireless (off-board) and CAN-based (on-board) communication hardware and software systems (as well as the sonde-coil and -electronics). The drive-module (2 ea.) are still responsible for bracing (and centering) to drive in push/pull fashion the robot train into and through the pipes and obstacles. The steering modules

  8. Experimental analytical study on heat pipes

    International Nuclear Information System (INIS)

    Ismail, K.A.R.; Liu, C.Y.; Murcia, N.

    1981-01-01

    An analytical model is developed for optimizing the thickness distribution of the porous material in heat pipes. The method was used to calculate, design and construct heat pipes with internal geometrical changes. Ordinary pipes are also constructed and tested together with the modified ones. The results showed that modified tubes are superior in performance and that the analytical model can predict their performance to within 1.5% precision. (Author) [pt

  9. SIZE REDUCTION OF ELECTROSTATIC PRECIPITATOR CHAMBER BY MODIFICATION OF GAS FLOW DISTRIBUTION

    Directory of Open Access Journals (Sweden)

    Beata Sładkowska-Rybka

    2014-10-01

    Full Text Available Electrostatic precipitators (ESP are one of the most effective devices for particulate emission control, removing from the exhaust gases even 99,9 % of dust particles. The collection efficiency of the ESP depends on a number of factors: mechanical design and electrical operating parameters, physical and chemical properties of cleaned gas, characteristic of dust particles suspended in the gas. Among the most important factors affecting the ESP effectiveness, the velocity and the distribution of gas flow in the ESP chamber should be also indicated. Significant increase in ESP efficiency is possible thanks to the application of Skewed Gas Flow Technology (SGFT. In this paper the computer simulations results are shown. Authors investigated the possibility of ESP chamber size reduction by modification of gas flow distribution.

  10. 1998 Annual Study Report. Standardization of methods for evaluating characteristics of high-strength, large-diameter steel pipes for superhigh-pressure natural gas pipelines; 1998 nendo seika hokokusho. Chokoatsu tennen gas pipeline yo kokyodo daikei kokan no tokusei hoho no hyojunka

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    The pipelines for safely transmitting superhigh-pressure natural gas should have excellent characteristics. The steel pipe is required to have a sufficient toughness, more concretely Charpy impact-absorbing energy, to prevent propagating shear fracture characteristic of natural gas pipelines. Recently, the natural gas pipeline is increasingly required to have higher design pressures (15 Mpa or higher) and grade (X80 or higher). In order to develop the techniques for simulating crack propagation in the propagating shear fracture of natural gas pipe lines as part of the programs to cope with these trends, the 1998 efforts were directed to reviewing the research results obtained so far and analysis of the problems to be solved and tasks to be taken, based on which the analytical procedure for gas releasing phenomena during the fracture process was basically developed, the material characteristic data were collected by the laboratory scale toughness tests, and the preliminary tests with rupture disks were conducted to verify the above analytical procedure. These efforts have established the bases for evaluating the characteristics of high-strength, large-diameter steel pipes in the light of safety against fracture, and greatly advanced the program towards the final target of developing the international specification drafts for toughness. (NEDO)

  11. The local distribution of Na I interstellar gas

    Science.gov (United States)

    Welsh, B. Y.; Craig, N.; Vedder, P. W.; Vallerga, J. V.

    1994-01-01

    We present high-resolution absorption measurements (lambda/Delta lambda approximately 75,000) of the interstellar Na I D lines at 5890 A toward 80 southern hemisphere early-type stars located in the local interstellar medium (LISM). Combining these results with other sodium measurements taken from the literature, we produce galactic maps of the distribution of neutral sodium column density for a total of 293 stars generally lying within approximately 250 pc of the Sun. These maps reveal the approximate shape of the mid-plane contours of the rarefied region of interstellar space termed the Local Bubble. Its shape is seen as highly asymmetric, with a radius ranging from 30 to 300 pc, and with an average radius of 60 pc. Similar plots of the Galactic mid-plane distribution of sources emitting extreme ultraviolet radiation show that they also trace out similar contours of the Local Bubble derived from Na I absorption measurements. We conclude that the Local Bubble absorption interface can be represented by a hydrogen column density, Nu(sub ETA) = 2 x 10(exp 19) cm(exp -2), which explains both the local distribution of Na I absorption and the observed galactic distribution of extreme ultraviolet sources. The derived mid-plane contours of the Bubble generally reproduce the large-scale features carved out in the interstellar medium by several nearby galactic shell structures.

  12. Risk analysis of highly combustible gas storage, supply, and distribution systems in PWR plants

    Energy Technology Data Exchange (ETDEWEB)

    Simion, G.P. [Science Applications International Corp., Albuquerque, NM (United States); VanHorn, R.L.; Smith, C.L.; Bickel, J.H.; Sattison, M.B. [EG and G Idaho, Inc., Idaho Falls, ID (United States); Bulmahn, K.D. [SCIENTECH, Inc., Idaho Falls, ID (United States)

    1993-06-01

    This report presents the evaluation of the potential safety concerns for pressurized water reactors (PWRs) identified in Generic Safety Issue 106, Piping and the Use of Highly Combustible Gases in Vital Areas. A Westinghouse four-loop PWR plant was analyzed for the risk due to the use of combustible gases (predominantly hydrogen) within the plant. The analysis evaluated an actual hydrogen distribution configuration and conducted several sensitivity studies to determine the potential variability among PWRs. The sensitivity studies were based on hydrogen and safety-related equipment configurations observed at other PWRs within the United States. Several options for improving the hydrogen distribution system design were identified and evaluated for their effect on risk and core damage frequency. A cost/benefit analysis was performed to determine whether alternatives considered were justifiable based on the safety improvement and economics of each possible improvement.

  13. Risk analysis of highly combustible gas storage, supply, and distribution systems in PWR plants

    International Nuclear Information System (INIS)

    Simion, G.P.; VanHorn, R.L.; Smith, C.L.; Bickel, J.H.; Sattison, M.B.; Bulmahn, K.D.

    1993-06-01

    This report presents the evaluation of the potential safety concerns for pressurized water reactors (PWRs) identified in Generic Safety Issue 106, Piping and the Use of Highly Combustible Gases in Vital Areas. A Westinghouse four-loop PWR plant was analyzed for the risk due to the use of combustible gases (predominantly hydrogen) within the plant. The analysis evaluated an actual hydrogen distribution configuration and conducted several sensitivity studies to determine the potential variability among PWRs. The sensitivity studies were based on hydrogen and safety-related equipment configurations observed at other PWRs within the United States. Several options for improving the hydrogen distribution system design were identified and evaluated for their effect on risk and core damage frequency. A cost/benefit analysis was performed to determine whether alternatives considered were justifiable based on the safety improvement and economics of each possible improvement

  14. Dutch gas distribution grid goes green: decision support tool for local biogas utilization

    NARCIS (Netherlands)

    Weidenaar, Teade; Hoekstra, Sipke; Wolters, Mannes

    2011-01-01

    A Decision Support Tool (DST) has been developed that will aid Distribution Service Operators (DSOs) in their decision making process on which investments to make in the gas distribution grid in order to facilitate the use of biogas. The DST considers both the conversion of biogas to electricity as

  15. A grain size distribution model for non-catalytic gas-solid reactions

    NARCIS (Netherlands)

    Heesink, Albertus B.M.; Prins, W.; van Swaaij, Willibrordus Petrus Maria

    1993-01-01

    A new model to describe the non-catalytic conversion of a solid by a reactant gas is proposed. This so-called grain size distribution (GSD) model presumes the porous particle to be a collection of grains of various sizes. The size distribution of the grains is derived from mercury porosimetry

  16. The automatic measurement of powder concentration distribution in flowing solid-gas mixtures

    International Nuclear Information System (INIS)

    Lech, M.

    1977-01-01

    A new radiation method for automatic measurement of powder concentration distribution in flowing solid-gas mixtures is presented. The method gives results of measurement in form of a graph of powder concentration distribution. The measurement using this method can be made in short time and with low error. (author)

  17. [Measurement on gas temperature distribution by tunable diode laser absorption spectroscopy].

    Science.gov (United States)

    Li, Ning; Yan, Jian-hua; Wang, Fei; Chi, Yong; Cen, Ke-fa

    2008-08-01

    The technique of tunable diode laser absorption spectroscopy (TDLAS) can be used for gas temperature distribution measurement by scanning multiple gas absorption lines with a tunable diode laser. The fundamental of gas temperature distribution measurement by TDLAS is introduced in the present paper, and the discretization strategy of equation for gas absorption is also given here. Using constrained linear least-square fitting method, the gas temperature distribution can be calculated with the help of physical constraints under the condition of uniform gas concentration and pressure. Based on the spectral parameters of four CO absorption lines near 6330 cm(-1) from HITRAN database, the model of two-temperature distribution at 300 and 600 K with each path length of 55 cm was set up. The effects of relative measurement error and different path length constraints of temperature bins on the gas temperature distribution measurement results were simulated by constrained linear least-square fitting. The results show that the temperature distribution calculation error increases as the relative measurement error rises. A measurement error of 5% could lead to a maximum relative error of 11%, and an average relative error of 2.2% for calculation result. And the weak physical constraints of path length for temperature bins could increase the calculation result error during the process of constrained linear least-square fitting. By setting up the model of two-temperature distribution with gas cells at room temperature as the cold section and in tube furnace as the hot section, the experiment of gas temperature distribution measurement in lab was carried out. Using four absorption lines of CO near 6330 cm(-1) scanned by VCSEL diode laser, and fitting the background laser intensity without absorption by the cubic polynomial to get the baseline signal, the integrals of spectral absorbance for gas temperature distribution measurement can be calculated. The relative calculation

  18. Proposed systematic methodology for analysis of Pb-210 radioactivity in residues produced in Brazilian natural gas pipes; Proposicao de um modelo analitico sistematico da atividade de Pb-210 em residuos gerados em linhas de gas

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Aloisio Cordilha

    2003-11-15

    Since the 80's, the potential radiological hazards due to the handling of solid wastes contaminated with Rn-222 long-lived progeny - Pb-210 in special - produced in gas pipes and removed by pig operations have been subject of growing concern abroad our country. Nevertheless, little or no attention has been paid to this matter in the Brazilian plants up to now, being these hazards frequently underestimated or even ignored. The main purpose of this work was to propose a systematic methodology for analysis of Pb-210 radioactivity in black powder samples from some Brazilian plants, through the evaluation of direct Pb-210 gamma spectrometry and Bi-210 beta counting technical viabilities. In both cases, one in five samples of black powder analysed showed relevant activity (above 1Bq/kg) of Pb-210, being these results probably related to particular features of each specific plant (production levels, reservoir geochemical profile, etc.), in such a way that a single pattern is not observed. For the proposed methodology, gamma spectrometry proved to be the most reliable technique, showing a 3.5% standard deviation, and, for a 95% confidence level, overall fitness in the range of Pb-210 concentration of activity presented in the standard sample reference sheet, provided by IAEA for intercomparison purposes. In the Brazilian scene, however, the availability of statistically supported evidences is insufficient to allow the potential radiological hazard due to the management of black powder to be discarded. Thus, further research efforts are recommended in order to detect the eventually critical regions or plants where gas exploration, production and processing practices will require a regular program of radiological surveillance, in the near future. (author)

  19. Spatial distribution of venous gas emboli in the lungs

    Science.gov (United States)

    Souders, J. E.; Doshier, J. B.; Polissar, N. L.; Hlastala, M. P.

    1999-01-01

    The distribution of gaseous pulmonary emboli is presumed to be determined by their buoyancy. We hypothesized that regional pulmonary blood flow may also influence their distribution. Therefore, pulmonary blood flow was measured in supine, anesthetized dogs with use of 15-microm fluorescent microspheres at baseline and during N(2) embolism. The animals were killed, and the lungs were excised, air-dried, and diced into approximately 2-cm(3) pieces with weights and spatial coordinates recorded. Embolism was defined as a >10% flow decrease relative to baseline. Vertically, the incidence of embolism increased substantially by 6 +/- 1% per additional centimeter in height compared with baseline (P = 0.0003). Embolism also increased radially by 3 +/- 1%/cm from the hilum (P = 0.002). There was a weaker but statistically significant increase in embolism to pieces with greater baseline flow, 9 +/- 2% for every 1. 0 increase in relative baseline flow (P = 0.008). We conclude that the distribution of gaseous emboli is influenced by buoyancy and flow dynamics within the pulmonary vasculature.

  20. THE EFFECT OF CHLORIDE AND ORTHOPHOSPHATE ON THE RELEASE OF IRON FROM A DRINKING WATER DISTRIBUTION SYSTEM CAST IRON PIPE

    Science.gov (United States)

    "Colored water" describes the appearance of drinking water that contains suspended particulate iron although the actual suspension color may be light yellow to red depending on water chemistry and particle properties. The release of iron from distribution system materials such a...

  1. Effect of Changing Treatment Disinfectants on the Microbiology of Distributed Water and Pipe Biofilm Communities using Conventional and Metagenomic Approaches

    Science.gov (United States)

    The purpose of this research was to add to our knowledge of chlorine and monochloramine disinfectants, with regards to effects on the microbial communities in distribution systems. A whole metagenome-based approach using sophisticated molecular tools (e.g., next generation sequen...

  2. SEALING LARGE-DIAMETER CAST-IRON PIPE JOINTS UNDER LIVE CONDITIONS

    Energy Technology Data Exchange (ETDEWEB)

    Kiran M. Kothari, Gerard T. Pittard

    2004-01-01

    Utilities in the U.S. operate over 75,000 km (47,000 miles) of old cast-iron pipes for gas distribution. The bell-and-spigot joints that connect pipe sections together tend to leak as these pipes age. Current repair practices are costly and highly disruptive. The objective of this program is to design, test and commercialize a robotic system capable of sealing multiple cast iron bell and spigot joints from a single pipe entry point. The proposed system will perform repairs while the pipe remains in service by traveling through the pipe, cleaning each joint surface, and installing a stainless-steel sleeve lined with an epoxy-impregnated felt across the joint. This approach will save considerable time and labor, avoid traffic disruption, and eliminate any requirement to interrupt service to customers (which would result in enormous expense to utilities). Technical challenges include: (1) repair sleeves must compensate for diametric variation and eccentricity of cast-iron pipes; (2) the assembly must travel long distances through pipes containing debris; (3) the pipe wall must be effectively cleaned in the immediate area of the joint to assure good bonding of the sleeve; and (4) an innovative bolt-on entry fitting is required to conduct repair operations on live mains. The development effort is divided into eleven tasks. Task 1--Program Management and Task 2--were completed in prior quarters while Task 3--Design and Fabricate Ratcheting Stainless-Steel Repair Sleeves has progressed to installing prototype sleeves in cast iron test pipe segments. Efforts in this quarter continued to focus on Tasks 4--8, with significant progress made in each. Task 4 (Design, Fabricate and Test Patch Setting Robotic Train) progressed to the design of the control electronics and pneumatic system to inflate the bladder robotic patch setting module. Task 5 (Design & Fabricate Pipe-Wall Cleaning Robot Train with Pan/Zoom/Tilt Camera) continued with additional in-pipe testing required to

  3. SEALING LARGE-DIAMETER CAST-IRON PIPE JOINTS UNDER LIVE CONDITIONS

    Energy Technology Data Exchange (ETDEWEB)

    Kiran M Kothari; Gerard T. Pittard

    2004-07-01

    Utilities in the U.S. operate over 75,000 km (47,000 miles) of old cast-iron pipes for gas distribution. The bell-and-spigot joints that connect pipe sections together tend to leak as these pipes age. Current repair practices are costly and highly disruptive. The objective of this program is to design, test and commercialize a robotic system capable of sealing multiple castiron bell and spigot joints from a single pipe entry point. The proposed system will perform repairs while the pipe remains in service by traveling through the pipe, cleaning each joint surface, and installing a stainless-steel sleeve lined with an epoxy-impregnated felt across the joint. This approach will save considerable time and labor, avoid traffic disruption, and eliminate any requirement to interrupt service to customers (which would result in enormous expense to utilities). Technical challenges include: (1) repair sleeves must compensate for diametric variation and eccentricity of cast-iron pipes; (2) the assembly must travel long distances through pipes containing debris; (3) the pipe wall must be effectively cleaned in the immediate area of the joint to assure good bonding of the sleeve; and (4) an innovative bolt-on entry fitting is required to conduct repair operations on live mains. The development effort is divided into eleven tasks. Task 1 (Program Management) and Task 2 (Establishment of Detailed Design Specifications) were completed in prior quarters while Task 3 (Design and Fabricate Ratcheting Stainless-Steel Repair Sleeves) has progressed to installing prototype sleeves in cast iron test pipe segments. Efforts in this quarter continued to focus on Tasks 4-8, with significant progress made in each. Task 4 (Design, Fabricate and Test Patch Setting Robotic Train) progressed to the design of the control electronics and pneumatic system to inflate the bladder robotic patch setting module. Task 5 (Design & Fabricate Pipe-Wall Cleaning Robot Train with Pan/Zoom/Tilt Camera

  4. SEALING LARGE-DIAMETER CAST-IRON PIPE JOINTS UNDER LIVE CONDITIONS

    Energy Technology Data Exchange (ETDEWEB)

    Kiran M. Kothari; Gerard T. Pittard

    2004-04-01

    Utilities in the U.S. operate over 75,000 km (47,000 miles) of old cast-iron pipes for gas distribution. The bell-and-spigot joints that connect pipe sections together tend to leak as these pipes age. Current repair practices are costly and highly disruptive. The objective of this program is to design, test and commercialize a robotic system capable of sealing multiple cast-iron bell and spigot joints from a single pipe entry point. The proposed system will perform repairs while the pipe remains in service by traveling through the pipe, cleaning each joint surface, and installing a stainless-steel sleeve lined with an epoxy-impregnated felt across the joint. This approach will save considerable time and labor, avoid traffic disruption, and eliminate any requirement to interrupt service to customers (which would result in enormous expense to utilities). Technical challenges include: (1) repair sleeves must compensate for diametric variation and eccentricity of cast-iron pipes; (2) the assembly must travel long distances through pipes containing debris; (3) the pipe wall must be effectively cleaned in the immediate area of the joint to assure good bonding of the sleeve; and (4) an innovative bolt-on entry fitting is required to conduct repair operations on live mains. The development effort is divided into eleven tasks. Task 1--Program Management and Task 2--were completed in prior quarters while Task 3--Design and Fabricate Ratcheting Stainless-Steel Repair Sleeves has progressed to installing prototype sleeves in cast iron test pipe segments. Efforts in this quarter continued to focus on Tasks 4--8, with significant progress made in each. Task 4 (Design, Fabricate and Test Patch Setting Robotic Train) progressed to the design of the control electronics and pneumatic system to inflate the bladder robotic patch setting module. Task 5 (Design & Fabricate Pipe-Wall Cleaning Robot Train with Pan/Zoom/Tilt Camera) continued with additional in-pipe testing required to

  5. FINANCING OF INVESTMENT PROJECTS OF GAS DISTRIBUTION ENTERPISES AS A FACTOR OF THEIR DEVELOPMENT

    Directory of Open Access Journals (Sweden)

    Svitlana Korol

    2016-03-01

    Full Text Available In the article theoretical questions of formation sources of financing investments   are  considered, the analysis of investment activities is carried out by the sources of funding for gas  utility. The purpose of this article is to identify priority sources of financing investment activities of gas distribution enterprises. The  methodology  of  research.  To  achieve  this  goal  the  author  used  methods  of  theoretical generalization; statistical and financial methods in the study of dynamics and structure of  investment; tabular methods to display the structure of the main sources of financing of  the  investment program of gas distribution enterprises; consistency and comparison, to determine the relationship between the main components of investment sources of financing. As a result of research by critical retrospective analysis to determine the structure of sources of financing investment activities of gas distribution enterprises. It is established that the main sources of financing the investment program are the tariffs for transportation and supply of gas, says the national Commission, carrying out state regulation in the areas of energy and  utilities (NCREU. It is filed the structure of the main financing sources of the investment  program of gas distribution enterprises. It is proved that the level of funding depends on the size  of NCREU rates and gas consumption. Scientific novelty of the article is lack in domestic and foreign areas of research priority  selection of sources financing of the investment program for gas distribution enterprises. The practical significance is that the theoretical concepts, practical results and conclusions of  articles that reveal the essence of the problem of investment sources of financing, can be used in  the activity of gas distribution enterprises taking into account the current state of development  of the economy. Keywords: investment  resources,  financing

  6. The impact of small scale cogeneration on the gas demand at distribution level

    International Nuclear Information System (INIS)

    Vandewalle, J.; D’haeseleer, W.

    2014-01-01

    Highlights: • Impact on the gas network of a massive implementation of cogeneration. • Distributed energy resources in a smart grid environment. • Optimisation of cogeneration scheduling. - Abstract: Smart grids are often regarded as an important step towards the future energy system. Combined heat and power (CHP) or cogeneration has several advantages in the context of the smart grid, which include the efficient use of primary energy and the reduction of electrical losses through transmission. However, the role of the gas network is often overlooked in this context. Therefore, this work presents an analysis of the impact of a massive implementation of small scale (micro) cogeneration units on the gas demand at distribution level. This work shows that using generic information in the simulations overestimates the impact of CHP. Furthermore, the importance of the thermal storage tank capacity on the impact on the gas demand is shown. Larger storage tanks lead to lower gas demand peaks and hence a lower impact on the gas distribution network. It is also shown that the use of an economically led controller leads to similar results compared to classical heat led control. Finally, it results that a low sell back tariff for electricity increases the impact of cogeneration on the gas demand peak

  7. Natural Gas Transmission and Distribution Model of the National Energy Modeling System. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-01-01

    The Natural Gas Transmission and Distribution Model (NGTDM) is the component of the National Energy Modeling System (NEMS) that is used to represent the domestic natural gas transmission and distribution system. The NGTDM is the model within the NEMS that represents the transmission, distribution, and pricing of natural gas. The model also includes representations of the end-use demand for natural gas, the production of domestic natural gas, and the availability of natural gas traded on the international market based on information received from other NEMS models. The NGTDM determines the flow of natural gas in an aggregate, domestic pipeline network, connecting domestic and foreign supply regions with 12 demand regions. The purpose of this report is to provide a reference document for model analysts, users, and the public that defines the objectives of the model, describes its basic design, provides detail on the methodology employed, and describes the model inputs, outputs, and key assumptions. Subsequent chapters of this report provide: an overview of NGTDM; a description of the interface between the NEMS and NGTDM; an overview of the solution methodology of the NGTDM; the solution methodology for the Annual Flow Module; the solution methodology for the Distributor Tariff Module; the solution methodology for the Capacity Expansion Module; the solution methodology for the Pipeline Tariff Module; and a description of model assumptions, inputs, and outputs.

  8. Distribution of medium-to-coarse glass beads in slurry pipe flow: evaluation of measured concentration profiles

    Czech Academy of Sciences Publication Activity Database

    Matoušek, Václav; Krupička, Jan; Pěník, Vojtěch

    2014-01-01

    Roč. 32, č. 2 (2014), s. 186-196 ISSN 0272-6351. [7th International Conference for Conveying and Handling of Particulate Solids (CHoPS). Friedrichshafen, 10.09.2013-13.09.2012] R&D Projects: GA ČR GA103/09/0383 Institutional support: RVO:67985874 Keywords : concentration distribution * high concentrated slurry * pipeline flow * slurry flow experiment Subject RIV: BK - Fluid Dynamics Impact factor: 0.523, year: 2014

  9. A Lagrangian View of Stratospheric Trace Gas Distributions

    Science.gov (United States)

    Schoeberl, M. R.; Sparling, L.; Dessler, A.; Jackman, C. H.; Fleming, E. L.

    1998-01-01

    As a result of photochemistry, some relationship between the stratospheric age-of-air and the amount of tracer contained within an air sample is expected. The existence of such a relationship allows inferences about transport history to be made from observations of chemical tracers. This paper lays down the conceptual foundations for the relationship between age and tracer amount, developed within a Lagrangian framework. In general, the photochemical loss depends not only on the age of the parcel but also on its path. We show that under the "average path approximation" that the path variations are less important than parcel age. The average path approximation then allows us to develop a formal relationship between the age spectrum and the tracer spectrum. Using the relation between the tracer and age spectra, tracer-tracer correlations can be interpreted as resulting from mixing which connects parts of the single path photochemistry curve, which is formed purely from the action of photochemistry on an irreducible parcel. This geometric interpretation of mixing gives rise to constraints on trace gas correlations, and explains why some observations are do not fall on rapid mixing curves. This effect is seen in the ATMOS observations.

  10. Federative competence conflicts in the natural gas sector distribution; Conflitos de competencias federativas no ambito da distribuicao do gas natural

    Energy Technology Data Exchange (ETDEWEB)

    Soares, Adriano; Nunes, Alessandro; Nascimento, Juliana; Gois, Luciana; Jardim, Mariana; Moura, Tacio; Campos, Vitor [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Faculdade de Direito

    2004-07-01

    This essay intends to broach the role played by the federative agents in the natural gas distribution regulation and analyses the conflict arisen from the new script of the article 25, para. 2nd of the Constitution, given by the amendment 5/95. For this, it is necessary to make a brief expose of the different types of non-tributary federative scope distribution and also to talk over about the natural problems from the lack of a clear appraisal of what canalized gas is, defining the state jurisdiction's object. Only then, it is possible to analyse its limits on the canalized gas local services distribution. In this context, it is evident that the role played by the state regulatory agent in promoting a favourable environment to the competition searching for alternatives concerning the problems of the natural monopoly. Equally important, is the study case of Amazonas, in which is enlightened the position of certain agencies and state agents when their constitutional sphere of influence is extrapolated. For the reasons exposed, it is imperative to improve the current forensic model to guarantee a more effective Union participation, at least to assure a minimum level of regulatory uniformization among the federative states. (author)

  11. A theoretical cost optimization model of reused flowback distribution network of regional shale gas development

    International Nuclear Information System (INIS)

    Li, Huajiao; An, Haizhong; Fang, Wei; Jiang, Meng

    2017-01-01

    The logistical issues surrounding the timing and transport of flowback generated by each shale gas well to the next is a big challenge. Due to more and more flowback being stored temporarily near the shale gas well and reused in the shale gas development, both transportation cost and storage cost are the heavy burden for the developers. This research proposed a theoretical cost optimization model to get the optimal flowback distribution solution for regional multi shale gas wells in a holistic perspective. Then, we used some empirical data of Marcellus Shale to do the empirical study. In addition, we compared the optimal flowback distribution solution by considering both the transportation cost and storage cost with the flowback distribution solution which only minimized the transportation cost or only minimized the storage cost. - Highlights: • A theoretical cost optimization model to get optimal flowback distribution solution. • An empirical study using the shale gas data in Bradford County of Marcellus Shale. • Visualization of optimal flowback distribution solutions under different scenarios. • Transportation cost is a more important factor for reducing the cost. • Help the developers to cut the storage and transportation cost of reusing flowback.

  12. 76 FR 2902 - National Fuel Gas Distribution Corporation; Notice of Motion for Extension of Rate Case Filing...

    Science.gov (United States)

    2011-01-18

    ... Energy Regulatory Commission Docket No. PR07-19-002 National Fuel Gas Distribution Corporation; Notice of..., National Fuel Gas Distribution Corporation (National Fuel) filed a request for an extension consistent with... Reporting Requirements of Intrastate Natural Gas Companies, Order No. 735, 131 FERC ] 61,150 (May 20, 2010...

  13. Report of the experts group on the taxation of the access to gas transport and distribution network

    International Nuclear Information System (INIS)

    2001-04-01

    In the framework of a new french gas industry organization (directive of the 22 june 1998), a concerting mission has been realized on prices taxation for the transport and distribution facilities. The following topics have been debated: the integration and competition of the european gas market, the gas market liberalization consistency and the taxation of transport and distribution network access. (A.L.B.)

  14. Conservation of bubble size distribution during gas reactive absorption in bubble column reactors

    Directory of Open Access Journals (Sweden)

    P. L.C. LAGE

    1999-12-01

    Full Text Available Conservation of the bubble size distribution function was applied to the reactive absorption of carbon dioxide in a bubble column reactor. The model developed was solved by the method of characteristics and by a Monte Carlo method. Simulations were carried out using simplified models for the liquid phase and for the gas-liquid mass transfer. Predictions of gas holdup and outlet gas composition showed that the concept of a mean bubble diameter is not applicable when the bubble size distribution is reasonably polydispersed. In these cases, the mass mean velocity and the numerical mean velocity of the bubbles are very different. Therefore, quantification of the polydispersion of bubbles was shown to be essential to gas-phase hydrodynamics modeling.

  15. Shield For Flexible Pipe

    Science.gov (United States)

    Ponton, Michael K.; Williford, Clifford B.; Lagen, Nicholas T.

    1995-01-01

    Cylindrical shield designed to fit around flexible pipe to protect nearby workers from injury and equipment from damage if pipe ruptures. Designed as pressure-relief device. Absorbs impact of debris ejected radially from broken flexible pipe. Also redirects flow of pressurized fluid escaping from broken pipe onto flow path allowing for relief of pressure while minimizing potential for harm.

  16. Decompression vs. Decomposition: Distribution, Amount, and Gas Composition of Bubbles in Stranded Marine Mammals.

    Science.gov (United States)

    de Quirós, Yara Bernaldo; González-Diaz, Oscar; Arbelo, Manuel; Sierra, Eva; Sacchini, Simona; Fernández, Antonio

    2012-01-01

    Gas embolic lesions linked to military sonar have been described in stranded cetaceans including beaked whales. These descriptions suggest that gas bubbles in marine mammal tissues may be more common than previously thought. In this study we have analyzed gas amount (by gas score) and gas composition within different decomposition codes using a standardized methodology. This broad study has allowed us to explore species-specific variability in bubble prevalence, amount, distribution, and composition, as well as masking of bubble content by putrefaction gases. Bubbles detected within the cardiovascular system and other tissues related to both pre- and port-mortem processes are a common finding on necropsy of stranded cetaceans. To minimize masking by putrefaction gases, necropsy, and gas sampling must be performed as soon as possible. Before 24 h post mortem is recommended but preferably within 12 h post mortem. At necropsy, amount of bubbles (gas score) in decomposition code 2 in stranded cetaceans was found to be more important than merely presence vs. absence of bubbles from a pathological point of view. Deep divers presented higher abundance of gas bubbles, mainly composed of 70% nitrogen and 30% CO(2), suggesting a higher predisposition of these species to suffer from decompression-related gas embolism.

  17. The gas distribution of comet Halley and its relation to the nucleus rotation

    Science.gov (United States)

    Cochran, Anita L.; Trout, Anthony P.

    1994-01-01

    We used a set of spatially resolved spectra of comet Halley to explore whether the gas distribution profile could be inverted to yield information on the rotation of the comet. The data were obtained both pre- and post-perihelion. The pre-perihelion data showed reasonable symmetry and so were used to define the lifetimes against photodissociation of the various molecules. These lifetimes were then used to define the lifetimes against photodissociation of the various molecules. These lifetimes were then used along with a nonsteady-state vectorial model to fit the post-perihelion gas distribution profiles. The resulting molecular lightcurves are compared with the photometric lightcurves of Schlicher et al. (1990) to show that the rotational information is encoded in the observed gas distribution within the coma. The molecular lightcurves can differentiate between the preferred Schlicher et al. average period and the period they find for the same time interval as the spectra.

  18. Minimization of Blast furnace Fuel Rate by Optimizing Burden and Gas Distribution

    Energy Technology Data Exchange (ETDEWEB)

    Dr. Chenn Zhou

    2012-08-15

    The goal of the research is to improve the competitive edge of steel mills by using the advanced CFD technology to optimize the gas and burden distributions inside a blast furnace for achieving the best gas utilization. A state-of-the-art 3-D CFD model has been developed for simulating the gas distribution inside a blast furnace at given burden conditions, burden distribution and blast parameters. The comprehensive 3-D CFD model has been validated by plant measurement data from an actual blast furnace. Validation of the sub-models is also achieved. The user friendly software package named Blast Furnace Shaft Simulator (BFSS) has been developed to simulate the blast furnace shaft process. The research has significant benefits to the steel industry with high productivity, low energy consumption, and improved environment.

  19. Fundamentals of piping design

    CERN Document Server

    Smith, Peter

    2013-01-01

    Written for the piping engineer and designer in the field, this two-part series helps to fill a void in piping literature,since the Rip Weaver books of the '90s were taken out of print at the advent of the Computer Aid Design(CAD) era. Technology may have changed, however the fundamentals of piping rules still apply in the digitalrepresentation of process piping systems. The Fundamentals of Piping Design is an introduction to the designof piping systems, various processes and the layout of pipe work connecting the major items of equipment forthe new hire, the engineering student and the vetera

  20. Distribution of gas in the inner comae of comets

    Science.gov (United States)

    Combi, Michael

    1990-01-01

    In order to understand the physical and chemical processes which produce the observed spatial morphology of the cometary coma, it is necessary to analyze observational data with physically meaningful models. Thus, a coupled program of theoretical modeling and complementary observational data analysis was undertaken regarding the spatial distributions of neutral gases in the coma. More, specifically, the particular topics of interest are: (1) the theoretical modeling of the nonequilibrium dynamics of the inner coma with emphasis on the region of the coma from the transition from collisional fluid flow out to the free-flow region and on observable conditions in the coma (i.e., density, outflow speed, and temperature); and (2) the model analysis of an important set of long-slit CCD spectra of comets. The side-by-side development of models along with the observation and analysis of data is an important and integral part of this project. The scientific community has in hand valuable observational and in situ data regarding one comet, Halley. It is important to use Halley as the benchmark by which other remotely observed comet data can be understood. Therefore, the self-consistant analysis of data with appropriate models is of the utmost importance. The data analysis work includes the analysis of the spatial profiles of (OI), NH2, CN, and C2.

  1. Linking particle and pore-size distribution parameters to soil gas transport properties

    DEFF Research Database (Denmark)

    Arthur, Emmanuel; Møldrup, Per; Schjønning, Per

    2012-01-01

    Accurate estimation of soil gas diffusivity (Dp/Do, the ratio of gas diffusion coefficients in soil and free air) and air permeability (ka) from basic texture and pore characteristics will be highly valuable for modeling soil gas transport and emission and their field-scale variations. From......, respectively) and the Campbell water retention parameter b were used to characterize particle and pore size distributions, respectively. Campbell b yielded a wide interval (4.6–26.2) and was highly correlated with α, β, and volumetric clay content. Both Dp/Do and ka followed simple power-law functions (PLFs...

  2. Analysis of Neutron Flux Distribution in Rsg-Gas Reactor With U-Mo Fuels

    Directory of Open Access Journals (Sweden)

    Taswanda Taryo

    2004-01-01

    Full Text Available The use of U-Mo fuels in research reactors seems to be promising and, recently, world researchers have carried out these such activities actively. The National Nuclear Energy Agency (BATAN which owns RSG-GAS reactor available in Serpong Research Center for Atomic Energy should anticipate this trend. It is, therefore, this research work on the use of U-Mo fuels in RSG-GAS reactor should be carried out. The work was focused on the analysis of neutron flux distribution in the RSG-GAS reactor using different content of molybdenum in U-Mo fuels. To begin with, RSG-GAS reactor core model was developed and simulated into X, Y and Z dimensions. Cross section of materials based on the developed cells of standard and control fuels was then generated using WIMS-D5-B. The criticality calculations were finally carried out applying BATAN-2DIFF code. The results showed that the neutron flux distribution obtained in U-Mo-fuel-based RSG-GAS core is very similar to those achieved in the 300-gram sillicide-fuel-based RSG-GAS reactor core. Indeed, the utilization of the U-Mo RSG-GAS core can be very similar to that of the high-density sillicide reactor core and even could be better in the future.

  3. Insulated pipe clamp design

    International Nuclear Information System (INIS)

    Anderson, M.J.; Hyde, L.L.; Wagner, S.E.; Severud, L.K.

    1980-01-01

    Thin wall large diameter piping for breeder reactor plants can be subjected to significant thermal shocks during reactor scrams and other upset events. On the Fast Flux Test Facility, the addition of thick clamps directly on the piping was undesired because the differential metal temperatures between the pipe wall and the clamp could have significantly reduced the pipe thermal fatigue life cycle capabilities. Accordingly, an insulated pipe clamp design concept was developed. 5 refs

  4. EFFORT OF STEEL PIPE JACKING IN TERMS OF IMPERFECTION PIPES AND HETEROGENEITY OF GROUND

    Directory of Open Access Journals (Sweden)

    K. Górski

    2016-06-01

    Full Text Available Purpose. The article presents problem of the influence of local inhomogeneities of ground on the internal forces in the steel pipe. Methodology. The authors presented the differences in the distributions of earth pressures for the pipes. One of the most common methods is the microtunneling technology. The examples of numerical analysis by finite element method (FEM have been calculated. Findings. The results of numerical analysis are presented for selected ground conditions and the distribution of internal forces in the flexible section of the steel pipe is also shown. Originality and Practical value. The obtained results clearly show the influence of flexural rigidity of the pipe on the internal forces, the influence of flexural rigidity and the soil stiffness on the size of the bending moments in the steel of pipe jacking. They depend on the interaction of soil – steel pipe.

  5. Stage 1: Expression of interest and consultation document for natural gas distribution in New Brunswick

    International Nuclear Information System (INIS)

    1998-01-01

    The New Brunswick government intends to award a franchise to establish natural gas distribution in the province. To this end, the province wishes to invite bids from qualified entities to establish gas distribution facilities. The province will select the preferred bidder(s) through a two-stage competitive bidding process. This document details the province's policy objectives, questions and issues to be addressed in stage 1 of the process, and the schedule for the process. Appendices include copies of relevant provincial statutes and regulations

  6. Process for forming integral edge seals in porous gas distribution plates utilizing a vibratory means

    Science.gov (United States)

    Feigenbaum, Haim (Inventor); Pudick, Sheldon (Inventor)

    1988-01-01

    A process for forming an integral edge seal in a gas distribution plate for use in a fuel cell. A seal layer is formed along an edge of a porous gas distribution plate by impregnating the pores in the layer with a material adapted to provide a seal which is operative dry or when wetted by an electrolyte of a fuel cell. Vibratory energy is supplied to the sealing material during the step of impregnating the pores to provide a more uniform seal throughout the cross section of the plate.

  7. EBR-II Cover Gas Cleanup System upgrade distributed control and front end computer systems

    International Nuclear Information System (INIS)

    Carlson, R.B.

    1992-01-01

    The Experimental Breeder Reactor II (EBR-II) Cover Gas Cleanup System (CGCS) control system was upgraded in 1991 to improve control and provide a graphical operator interface. The upgrade consisted of a main control computer, a distributed control computer, a front end input/output computer, a main graphics interface terminal, and a remote graphics interface terminal. This paper briefly describes the Cover Gas Cleanup System and the overall control system; gives reasons behind the computer system structure; and then gives a detailed description of the distributed control computer, the front end computer, and how these computers interact with the main control computer. The descriptions cover both hardware and software

  8. Health risk assessment linked with purified biogas injection in a natural gas distribution system

    International Nuclear Information System (INIS)

    Leroux, Carole; Modelon, Hugues; Rousselle, Christophe; Zdanevitch, Isabelle; Evanno, Sebastien

    2009-06-01

    This document provides for the opinion of the French Agency for Environmental and Occupational Health and Safety (Afsset) expressed after the collective expertise carried out for the evaluation of the health risk linked with biogas injection in the natural gas distribution system. Following the recommendations issued by the Afsset, works have been started in order to collect the sludge-derived biogas and to analyse its composition. These data will be used to assess accidental risks (resulting from biogas valorisation, pipeline transport, industrial and domestic energy valorisation) as well as health risks for users (resulting from the injection in the natural gas distribution system)

  9. Gas in Andean countries

    International Nuclear Information System (INIS)

    Campos Pinzon, Rafael

    2000-01-01

    The paper explores aspects of gas integration among Colombia, Venezuela, Ecuador and Peru. A comparison of the GDP is made, gas reserves are provided and the existent nets of gas-pipe are included in Colombia and Venezuela

  10. Diffusion of dilute gas in arrays of randomly distributed, vertically aligned, high-aspect-ratio cylinders.

    Science.gov (United States)

    Szmyt, Wojciech; Guerra, Carlos; Utke, Ivo

    2017-01-01

    In this work we modelled the diffusive transport of a dilute gas along arrays of randomly distributed, vertically aligned nanocylinders (nanotubes or nanowires) as opposed to gas diffusion in long pores, which is described by the well-known Knudsen theory. Analytical expressions for (i) the gas diffusion coefficient inside such arrays, (ii) the time between collisions of molecules with the nanocylinder walls (mean time of flight), (iii) the surface impingement rate, and (iv) the Knudsen number of such a system were rigidly derived based on a random-walk model of a molecule that undergoes memoryless, diffusive reflections from nanocylinder walls assuming the molecular regime of gas transport. It can be specifically shown that the gas diffusion coefficient inside such arrays is inversely proportional to the areal density of cylinders and their mean diameter. An example calculation of a diffusion coefficient is delivered for a system of titanium isopropoxide molecules diffusing between vertically aligned carbon nanotubes. Our findings are important for the correct modelling and optimisation of gas-based deposition techniques, such as atomic layer deposition or chemical vapour deposition, frequently used for surface functionalisation of high-aspect-ratio nanocylinder arrays in solar cells and energy storage applications. Furthermore, gas sensing devices with high-aspect-ratio nanocylinder arrays and the growth of vertically aligned carbon nanotubes need the fundamental understanding and precise modelling of gas transport to optimise such processes.

  11. Diffusion of dilute gas in arrays of randomly distributed, vertically aligned, high-aspect-ratio cylinders

    Directory of Open Access Journals (Sweden)

    Wojciech Szmyt

    2017-01-01

    Full Text Available In this work we modelled the diffusive transport of a dilute gas along arrays of randomly distributed, vertically aligned nanocylinders (nanotubes or nanowires as opposed to gas diffusion in long pores, which is described by the well-known Knudsen theory. Analytical expressions for (i the gas diffusion coefficient inside such arrays, (ii the time between collisions of molecules with the nanocylinder walls (mean time of flight, (iii the surface impingement rate, and (iv the Knudsen number of such a system were rigidly derived based on a random-walk model of a molecule that undergoes memoryless, diffusive reflections from nanocylinder walls assuming the molecular regime of gas transport. It can be specifically shown that the gas diffusion coefficient inside such arrays is inversely proportional to the areal density of cylinders and their mean diameter. An example calculation of a diffusion coefficient is delivered for a system of titanium isopropoxide molecules diffusing between vertically aligned carbon nanotubes. Our findings are important for the correct modelling and optimisation of gas-based deposition techniques, such as atomic layer deposition or chemical vapour deposition, frequently used for surface functionalisation of high-aspect-ratio nanocylinder arrays in solar cells and energy storage applications. Furthermore, gas sensing devices with high-aspect-ratio nanocylinder arrays and the growth of vertically aligned carbon nanotubes need the fundamental understanding and precise modelling of gas transport to optimise such processes.

  12. Two modelling approaches to water-quality simulation in a flooded iron-ore mine (Saizerais, Lorraine, France): a semi-distributed chemical reactor model and a physically based distributed reactive transport pipe network model.

    Science.gov (United States)

    Hamm, V; Collon-Drouaillet, P; Fabriol, R

    2008-02-19

    The flooding of abandoned mines in the Lorraine Iron Basin (LIB) over the past 25 years has degraded the quality of the groundwater tapped for drinking water. High concentrations of dissolved sulphate have made the water unsuitable for human consumption. This problematic issue has led to the development of numerical tools to support water-resource management in mining contexts. Here we examine two modelling approaches using different numerical tools that we tested on the Saizerais flooded iron-ore mine (Lorraine, France). A first approach considers the Saizerais Mine as a network of two chemical reactors (NCR). The second approach is based on a physically distributed pipe network model (PNM) built with EPANET 2 software. This approach considers the mine as a network of pipes defined by their geometric and chemical parameters. Each reactor in the NCR model includes a detailed chemical model built to simulate quality evolution in the flooded mine water. However, in order to obtain a robust PNM, we simplified the detailed chemical model into a specific sulphate dissolution-precipitation model that is included as sulphate source/sink in both a NCR model and a pipe network model. Both the NCR model and the PNM, based on different numerical techniques, give good post-calibration agreement between the simulated and measured sulphate concentrations in the drinking-water well and overflow drift. The NCR model incorporating the detailed chemical model is useful when a detailed chemical behaviour at the overflow is needed. The PNM incorporating the simplified sulphate dissolution-precipitation model provides better information of the physics controlling the effect of flow and low flow zones, and the time of solid sulphate removal whereas the NCR model will underestimate clean-up time due to the complete mixing assumption. In conclusion, the detailed NCR model will give a first assessment of chemical processes at overflow, and in a second time, the PNM model will provide more

  13. Development and perspectives of PE for gas networks in Italy

    International Nuclear Information System (INIS)

    Bergamino, R.; Cammelli, W.; Torre, C.

    1999-01-01

    After comparing the result of two large surveys carried out in 1998 and 1992 on the utilization of PE pipes for gas distribution, the features of PE pipe, which allow the adoption of innovative techniques such as 'rapid trenching' for the laying of new pipelines and 'NO-DIG' for the relining of old on, are described. The technical, operational and economical fea-activities developed in this field by AMGA SpA Genoa. Besides, the time behaviour of PE pipes welding is evaluated on the basis of values taken from AMGA's database [it

  14. Pipe Leak Detection Technology Development

    Science.gov (United States)

    The U. S. Environmental Protection Agency (EPA) has determined that one of the nation’s biggest infrastructural needs is the replacement or rehabilitation of the water distribution and transmission systems. The institution of more effective pipe leak detection technology will im...

  15. Intestinal gas content and distribution in health and in patients with functional gut symptoms.

    Science.gov (United States)

    Bendezú, R A; Barba, E; Burri, E; Cisternas, D; Malagelada, C; Segui, S; Accarino, A; Quiroga, S; Monclus, E; Navazo, I; Malagelada, J-R; Azpiroz, F

    2015-09-01

    The precise relation of intestinal gas to symptoms, particularly abdominal bloating and distension remains incompletely elucidated. Our aim was to define the normal values of intestinal gas volume and distribution and to identify abnormalities in relation to functional-type symptoms. Abdominal computed tomography scans were evaluated in healthy subjects (n = 37) and in patients in three conditions: basal (when they were feeling well; n = 88), during an episode of abdominal distension (n = 82) and after a challenge diet (n = 24). Intestinal gas content and distribution were measured by an original analysis program. Identification of patients outside the normal range was performed by machine learning techniques (one-class classifier). Results are expressed as median (IQR) or mean ± SE, as appropriate. In healthy subjects the gut contained 95 (71, 141) mL gas distributed along the entire lumen. No differences were detected between patients studied under asymptomatic basal conditions and healthy subjects. However, either during a spontaneous bloating episode or once challenged with a flatulogenic diet, luminal gas was found to be increased and/or abnormally distributed in about one-fourth of the patients. These patients detected outside the normal range by the classifier exhibited a significantly greater number of abnormal features than those within the normal range (3.7 ± 0.4 vs 0.4 ± 0.1; p distribution of intestinal gas in normal conditions and in relation to functional gastrointestinal symptoms. © 2015 John Wiley & Sons Ltd.

  16. Quality of the log-geometric distribution extrapolation for smaller undiscovered oil and gas pool size

    Science.gov (United States)

    Chenglin, L.; Charpentier, R.R.

    2010-01-01

    The U.S. Geological Survey procedure for the estimation of the general form of the parent distribution requires that the parameters of the log-geometric distribution be calculated and analyzed for the sensitivity of these parameters to different conditions. In this study, we derive the shape factor of a log-geometric distribution from the ratio of frequencies between adjacent bins. The shape factor has a log straight-line relationship with the ratio of frequencies. Additionally, the calculation equations of a ratio of the mean size to the lower size-class boundary are deduced. For a specific log-geometric distribution, we find that the ratio of the mean size to the lower size-class boundary is the same. We apply our analysis to simulations based on oil and gas pool distributions from four petroleum systems of Alberta, Canada and four generated distributions. Each petroleum system in Alberta has a different shape factor. Generally, the shape factors in the four petroleum systems stabilize with the increase of discovered pool numbers. For a log-geometric distribution, the shape factor becomes stable when discovered pool numbers exceed 50 and the shape factor is influenced by the exploration efficiency when the exploration efficiency is less than 1. The simulation results show that calculated shape factors increase with those of the parent distributions, and undiscovered oil and gas resources estimated through the log-geometric distribution extrapolation are smaller than the actual values. ?? 2010 International Association for Mathematical Geology.

  17. Statistical distribution for generalized ideal gas of fractional-statistics particles

    International Nuclear Information System (INIS)

    Wu, Y.

    1994-01-01

    We derive the occupation-number distribution in a generalized ideal gas of particles obeying fractional statistics, including mutual statistics, by adopting a state-counting definition. When there is no mutual statistics, the statistical distribution interpolates between bosons and fermions, and respects a fractional exclusion principle (except for bosons). Anyons in a strong magnetic field at low temperatures constitute such a physical system. Applications to the thermodynamic properties of quasiparticle excitations in the Laughlin quantum Hall fluid are discussed

  18. New ultrasonographic evaluation of stool and/or gas distribution for treatment of chronic constipation.

    Science.gov (United States)

    Manabe, Noriaki; Kamada, Tomoari; Hata, Jiro; Haruma, Ken

    2018-03-01

    The first aim of this study was to develop a new ultrasonographic method (US) to evaluate stool and/or gas distribution. The second aim was to apply this method to compare stool and/or gas distribution between healthy subjects and patients with chronic constipation and evaluate whether US parameters could be an alternative to the colonic transit time (CTT). We enrolled seven healthy volunteers (four men, three women; mean age 29.3 ± 5.2 years) who underwent US and computed tomography (CT) on the same day to evaluate the reproducibility of US results. We then enrolled 268 patients with chronic constipation (94 men, 174 women; mean age 63.3 ± 4.2 years) and 66 age- and sex-matched healthy subjects (controls). The transverse diameters of four segments of the colon [ascending (AC), transverse (TC), descending (DC), and sigmoid (SC)] and the rectum (R) were measured, and their stool and/or gas distribution was evaluated using the constipation index (CI) [AC + TC + DC + SC + R/5] and left/right (L/R) distribution [(DC + SC)/(AC + TC)]. The CTT was assessed using radiopaque markers. All healthy subjects underwent US and CT successfully, with a sufficiently high reproducibility coefficient for this method and significant correlation between the US and CT parameters. The stool and/or gas distribution evaluated by US showed a significant difference in one of the US parameters between healthy subjects and patients, and the CI was an indirect indicator for the CTT. These findings may assist physicians evaluate stool and/or gas distribution of patients with chronic constipation, which is an indirect indicator for CTT.

  19. High performance flexible heat pipes

    Science.gov (United States)

    Shaubach, R. M.; Gernert, N. J.

    1985-01-01

    A Phase I SBIR NASA program for developing and demonstrating high-performance flexible heat pipes for use in the thermal management of spacecraft is examined. The program combines several technologies such as flexible screen arteries and high-performance circumferential distribution wicks within an envelope which is flexible in the adiabatic heat transport zone. The first six months of work during which the Phase I contract goal were met, are described. Consideration is given to the heat-pipe performance requirements. A preliminary evaluation shows that the power requirement for Phase II of the program is 30.5 kilowatt meters at an operating temperature from 0 to 100 C.

  20. CFD gas distribution analysis for different continuous-miner scrubber redirection configurations.

    Science.gov (United States)

    Zheng, Y; Organiscak, J A; Zhou, L; Beck, T W; Rider, J P

    2017-01-01

    The U.S. National Institute for Occupational Safety and Health (NIOSH)'s Pittsburgh Mining Research Division (PMRD) recently developed a series of models using computational fluid dynamics (CFD) to study gas distribution around a continuous mining machine with various fan-powered flooded bed scrubber discharge configurations in an exhaust curtain working face. CFD models utilizing species transport model without reactions in FLUENT were constructed to evaluate the redirection of scrubber discharge toward the mining face rather than behind the return curtain. The study illustrates the gas distribution in the slab (second) cut. The following scenarios are considered in this study: 100 percent of the discharge redirected back toward the face on the off-curtain side; 100 percent of the discharge redirected back toward the face, but divided equally to both sides; and 15 percent of the discharge redirected toward the face on the off-curtain side, with 85 percent directed toward the return curtain. These models are compared against a model with a conventional scrubber discharge where air is directed away from the face into the return. The models were validated against experimental data, proving to accurately predict sulfur hexafluoride (SF 6 ) gas levels at four gas monitoring locations. This study includes a predictive simulation examining a 45° scrubber angle compared with the 23° angle for the 100 percent redirected, equally divided case. This paper describes the validation of the CFD models based on experimental data of the gas distribution results.

  1. Fractal analysis of the dark matter and gas distributions in the Mare-Nostrum universe

    International Nuclear Information System (INIS)

    Gaite, José

    2010-01-01

    We develop a method of multifractal analysis of N-body cosmological simulations that improves on the customary counts-in-cells method by taking special care of the effects of discreteness and large scale homogeneity. The analysis of the Mare-Nostrum simulation with our method provides strong evidence of self-similar multifractal distributions of dark matter and gas, with a halo mass function that is of Press-Schechter type but has a power-law exponent -2, as corresponds to a multifractal. Furthermore, our analysis shows that the dark matter and gas distributions are indistinguishable as multifractals. To determine if there is any gas biasing, we calculate the cross-correlation coefficient, with negative but inconclusive results. Hence, we develop an effective Bayesian analysis connected with information theory, which clearly demonstrates that the gas is biased in a long range of scales, up to the scale of homogeneity. However, entropic measures related to the Bayesian analysis show that this gas bias is small (in a precise sense) and is such that the fractal singularities of both distributions coincide and are identical. We conclude that this common multifractal cosmic web structure is determined by the dynamics and is independent of the initial conditions

  2. Insulated pipe clamp design

    International Nuclear Information System (INIS)

    Anderson, M.J.; Hyde, L.L.; Wagner, S.E.; Severud, L.K.

    1980-01-01

    Thin wall large diameter piping for breeder reactor plants can be subjected to significant thermal shocks during reactor scrams and other upset events. On the Fast Flux Test Facility, the addition of thick clamps directly on the piping was undesired because the differential metal temperatures between the pipe wall and the clamp could have significantly reduced the pipe thermal fatigue life cycle capabilities. Accordingly, an insulated pipe clamp design concept was developed. The design considerations and methods along with the development tests are presented. Special considerations to guard against adverse cracking of the insulation material, to maintain the clamp-pipe stiffness desired during a seismic event, to minimize clamp restraint on the pipe during normal pipe heatup, and to resist clamp rotation or spinning on the pipe are emphasized

  3. Piping Stress Analysis

    International Nuclear Information System (INIS)

    Setjo, Renaningsih

    2000-01-01

    Piping stress analysis on Primary Sampling System, Reactor Cooling System, and Feedwater System for AP600 have been performed. Piping stress analysis is one of the requirements in the design of piping system. Piping stress is occurred due to static and dynamic loads during service. Analysis was carried out. Using PS+CAEPIPE software based on the individual and combination loads with assumption that failure could be happened during normal, upset, emergency and faulted condition as describe in ASME III/ANSI B31.1. With performing the piping stress analysis, the layout (proper pipe routing) of the piping system can be design with the requirements of piping stress and pipe supports in mind I.e sufficient flexibility for thermal expansion, etc to commensurate with the i tended service such as temperatures, pressure, seismic and anticipated loading

  4. Flexible ocean upwelling pipe

    Science.gov (United States)

    Person, Abraham

    1980-01-01

    In an ocean thermal energy conversion facility, a cold water riser pipe is releasably supported at its upper end by the hull of the floating facility. The pipe is substantially vertical and has its lower end far below the hull above the ocean floor. The pipe is defined essentially entirely of a material which has a modulus of elasticity substantially less than that of steel, e.g., high density polyethylene, so that the pipe is flexible and compliant to rather than resistant to applied bending moments. The position of the lower end of the pipe relative to the hull is stabilized by a weight suspended below the lower end of the pipe on a flexible line. The pipe, apart from the weight, is positively buoyant. If support of the upper end of the pipe is released, the pipe sinks to the ocean floor, but is not damaged as the length of the line between the pipe and the weight is sufficient to allow the buoyant pipe to come to a stop within the line length after the weight contacts the ocean floor, and thereafter to float submerged above the ocean floor while moored to the ocean floor by the weight. The upper end of the pipe, while supported by the hull, communicates to a sump in the hull in which the water level is maintained below the ambient water level. The sump volume is sufficient to keep the pipe full during heaving of the hull, thereby preventing collapse of the pipe.

  5. Water Distribution Lines, Includes water pipes (not connections to structures, fire hydrants and other features. Capture in Microstation and does not contain attribution. Has annotation and is converted to GIS semi-anually. Only available upon permission., Published in 2011, 1:2400 (1in=200ft) scale, Howard County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Water Distribution Lines dataset current as of 2011. Includes water pipes (not connections to structures, fire hydrants and other features. Capture in Microstation...

  6. Modelling of fiberglass pipe destruction process

    Directory of Open Access Journals (Sweden)

    А. К. Николаев

    2017-03-01

    Full Text Available The article deals with important current issue of oil and gas industry of using tubes made of high-strength composite corrosion resistant materials. In order to improve operational safety of industrial pipes it is feasible to use composite fiberglass tubes. More than half of the accidents at oil and gas sites happen at oil gathering systems due to high corrosiveness of pumped fluid. To reduce number of accidents and improve environmental protection we need to solve the issue of industrial pipes durability. This problem could be solved by using composite materials from fiberglass, which have required physical and mechanical properties for oil pipes. The durability and strength can be monitored by a fiberglass winding method, number of layers in composite material and high corrosion-resistance properties of fiberglass. Usage of high-strength composite materials in oil production is economically feasible; fiberglass pipes production is cheaper than steel pipes. Fiberglass has small volume weight, which simplifies pipe transportation and installation. In order to identify the efficiency of using high-strength composite materials at oil production sites we conducted a research of their physical-mechanical properties and modelled fiber pipe destruction process.

  7. pressure distribution in a layered reservoir with gas-cap and bottom

    African Journals Online (AJOL)

    2012-07-02

    Jul 2, 2012 ... pressure derivatives, interlayer cross flow, heterogeneity, reservoir characterization, pressure distribution, dimensionless pressure. 1. Introduction. Oil production from a layered reservoir with a top gas cap and bottom water acting simultaneously poses serious challenges of rate and pressure monitoring.

  8. Gas Chromatographic Verification of a Mathematical Model: Product Distribution Following Methanolysis Reactions.

    Science.gov (United States)

    Lam, R. B.; And Others

    1983-01-01

    Investigated application of binomial statistics to equilibrium distribution of ester systems by employing gas chromatography to verify the mathematical model used. Discusses model development and experimental techniques, indicating the model enables a straightforward extension to symmetrical polyfunctional esters and presents a mathematical basis…

  9. Pirate, the development of an autonomous gas distribution system inspection robot

    NARCIS (Netherlands)

    Pulles, C.; Dertien, Edwin Christian; van de Pol, H.J.; Nispeling, R.

    2008-01-01

    A consortium of four companies is developing an autonomous inspection system for small diameter, low pressure gas distribution mains. Such a system could eventually replace the current practice of leak survey and improve the assessment of the quality of the mains, being able to investigate the mains

  10. Pore size distribution effect on rarefied gas transport in porous media

    Science.gov (United States)

    Hori, Takuma; Yoshimoto, Yuta; Takagi, Shu; Kinefuchi, Ikuya

    2017-11-01

    Gas transport phenomena in porous media are known to strongly influence the performance of devices such as gas separation membranes and fuel cells. Knudsen diffusion is a dominant flow regime in these devices since they have nanoscale pores. Many experiments have shown that these porous media have complex structures and pore size distributions; thus, the diffusion coefficient in these media cannot be easily assessed. Previous studies have reported that the characteristic pore diameter of porous media can be defined in light of the pore size distribution; however, tortuosity factor, which is necessary for the evaluation of diffusion coefficient, is still unknown without gas transport measurements or simulations. Thus, the relation between pore size distributions and tortuosity factors is required to obtain the gas transport properties. We perform numerical simulations to prove the relation between them. Porous media are numerically constructed while satisfying given pore size distributions. Then, the mean-square displacement simulation is performed to obtain the tortuosity factors of the constructed porous media.. This paper is based on results obtained from a project commissioned by the New Energy and Industrial Development Organization (NEDO).

  11. Yang-Yang thermometry and momentum distribution of a trapped one-dimensional Bose gas

    NARCIS (Netherlands)

    Davis, M.J.; Blakie, P.B.; van Amerongen, A.H.; van Druten, N.J.; Kheruntsyan, K.V.

    2012-01-01

    We describe the use of the exact Yang-Yang solutions for the one-dimensional Bose gas to enable accurate kinetic-energy thermometry based on the root-mean-square width of an experimentally measured momentum distribution. Furthermore, we use the stochastic projected Gross-Pitaevskii theory to provide

  12. Superstatistical Energy Distributions of an Ion in an Ultracold Buffer Gas.

    Science.gov (United States)

    Rouse, I; Willitsch, S

    2017-04-07

    An ion in a radio frequency ion trap interacting with a buffer gas of ultracold neutral atoms is a driven dynamical system which has been found to develop a nonthermal energy distribution with a power law tail. The exact analytical form of this distribution is unknown, but has often been represented empirically by q-exponential (Tsallis) functions. Based on the concepts of superstatistics, we introduce a framework for the statistical mechanics of an ion trapped in an rf field subject to collisions with a buffer gas. We derive analytic ion secular energy distributions from first principles both neglecting and including the effects of the thermal energy of the buffer gas. For a buffer gas with a finite temperature, we prove that Tsallis statistics emerges from the combination of a constant heating term and multiplicative energy fluctuations. We show that the resulting distributions essentially depend on experimentally controllable parameters paving the way for an accurate control of the statistical properties of ion-atom hybrid systems.

  13. 75 FR 5244 - Pipeline Safety: Integrity Management Program for Gas Distribution Pipelines; Correction

    Science.gov (United States)

    2010-02-02

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration 49 CFR Part 192 [Docket No. PHMSA-RSPA-2004-19854; Amdt. 192-113] RIN 2137-AE15 Pipeline Safety: Integrity Management Program for Gas Distribution Pipelines; Correction AGENCY: Pipeline and Hazardous Materials Safety...

  14. Analysis of Energy Storage System with Distributed Hydrogen Production and Gas Turbine

    Directory of Open Access Journals (Sweden)

    Kotowicz Janusz

    2017-12-01

    Full Text Available Paper presents the concept of energy storage system based on power-to-gas-to-power (P2G2P technology. The system consists of a gas turbine co-firing hydrogen, which is supplied from a distributed electrolysis installations, powered by the wind farms located a short distance from the potential construction site of the gas turbine. In the paper the location of this type of investment was selected. As part of the analyses, the area of wind farms covered by the storage system and the share of the electricity production which is subjected storage has been changed. The dependence of the changed quantities on the potential of the hydrogen production and the operating time of the gas turbine was analyzed. Additionally, preliminary economic analyses of the proposed energy storage system were carried out.

  15. Design of the ATLAS New Small Wheel Gas Distribution System for the Micromegas Detector Modules

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00084094; The ATLAS collaboration; Alexopoulos, Theodoros; Maltezos, Stavros; Vlachos, Sotirios; Karentzos, Efstathios; Koulouris, Aimilianos; Moschovakos, Paris; Koutelieris, Georgios

    2016-01-01

    In this work we present and describe the methodology, the particular calculations and simulations accordingly to achieve the appropriate gas flow rates ensuring a uniform gas distribution among the same type of NSW Micromegas modules. The majority of the components used are in large multiplicity so space saving criteria is taking into account and simplicity on the performance with respect to the total cost as well. An appropriate simulation program has been developed for studying the overall gas system determining the gauge pressure, flow rate in the crucial points and branches, respectively. Moreover, an overall prototype configuration, implemented at the NTUA laboratory and based on the Lock-in Amplifier technique to be used in conjunction with the gas leak test via the FRL method is presented. The obtained performances, by means of sensitivity and S/N ratio improvement, are also discussed.

  16. Analysis of Energy Storage System with Distributed Hydrogen Production and Gas Turbine

    Science.gov (United States)

    Kotowicz, Janusz; Bartela, Łukasz; Dubiel-Jurgaś, Klaudia

    2017-12-01

    Paper presents the concept of energy storage system based on power-to-gas-to-power (P2G2P) technology. The system consists of a gas turbine co-firing hydrogen, which is supplied from a distributed electrolysis installations, powered by the wind farms located a short distance from the potential construction site of the gas turbine. In the paper the location of this type of investment was selected. As part of the analyses, the area of wind farms covered by the storage system and the share of the electricity production which is subjected storage has been changed. The dependence of the changed quantities on the potential of the hydrogen production and the operating time of the gas turbine was analyzed. Additionally, preliminary economic analyses of the proposed energy storage system were carried out.

  17. Study On Seismic Identification And Distribution Characters Of Marine Gas Hydrate In Okinawa Trough

    Science.gov (United States)

    Fang, Y.; Jin, X.; Li, M.; Tang, Y.

    2003-04-01

    The paper studies the formation processes and distribution of marine gas hydrate, through systematically and thoroughly analyzing the geological setting, gas sources and distribution features of the most marine gas hydrate deposits around the world. Based on study of the geologic features in Okinawa Trough and adjacent area, it is showed that there exist favorable geological conditions for the formation of gas hydrate, and the seismic indicator -BSR has also been identified from multi-channel digit seismic data by re-processing and analyzing. This shows that Okinawa Trough and adjacent sea area may distribute a mass of gas hydrate sedimentary deposit. Then the paper discusses the prospect of the gas hydrate resource in Okinawa Trough and adjacent sea area, based on the calculating of the hydrate stability zone thickness. Main conclusions of the paper can be summed up as follows: Based on the systematically comparative analysis of the marine gas hydrate deposits in different marine gas hydrate accumulate belts, the paper summarizes the different geologic formation processes and characters of the gas hydrate. And the importance of the continuous supplementation of the gas source, the transporting and accumulating of the gaseous fluid during the formation processes of the gas hydrate, and the preservation conditions of the gas hydrate deposit are discussed. It is thought that the Okinawa Trough (especially the west slope of the Trough) has the favorable conditions for gas hydrate through the analysis of its geologic features. The geologic features of Okinawa Trough, such as water depth, low temperature of bottom water, very thick sediments with high organic matter content, a large amount of gas from deep parts induced by the upward of the high temperature mantle flow under the Trough, very developed fracture system, and lots of pore space in the under-compacted sediment induced by the rapid sedimentation-are beneficial to form gas hydrate. This provided the advantaged

  18. Pipe drafting and design

    CERN Document Server

    Parisher, Roy A; Parisher

    2000-01-01

    Pipe designers and drafters provide thousands of piping drawings used in the layout of industrial and other facilities. The layouts must comply with safety codes, government standards, client specifications, budget, and start-up date. Pipe Drafting and Design, Second Edition provides step-by-step instructions to walk pipe designers and drafters and students in Engineering Design Graphics and Engineering Technology through the creation of piping arrangement and isometric drawings using symbols for fittings, flanges, valves, and mechanical equipment. The book is appropriate primarily for pipe

  19. Momentum distributions of selected rare-gas atoms probed by intense femtosecond laser pulses

    DEFF Research Database (Denmark)

    Abu-Samha, Mahmoud; Madsen, Lars Bojer

    2011-01-01

    We provide a direct comparison between numerical and experimental (Rudenko et al 2004 J. Phys. B: At. Mol. Opt. Phys. 37 L407) photoelectron momentum distributions in strong-field ionization of selected rare-gas atoms (He, Ne and Ar), probed by femtosecond linearly polarized laser pulses. The cal......We provide a direct comparison between numerical and experimental (Rudenko et al 2004 J. Phys. B: At. Mol. Opt. Phys. 37 L407) photoelectron momentum distributions in strong-field ionization of selected rare-gas atoms (He, Ne and Ar), probed by femtosecond linearly polarized laser pulses....... The calculations are performed by solving the time-dependent Schrödinger equation within the single-active-electron approximation, and focal-volume effects are taken into account by appropriately averaging the results. The resulting momentum distributions are in quantitative agreement with the experimental...

  20. Current distribution measurements inside an electromagnetic plasma gun operated in a gas-puff mode.

    Science.gov (United States)

    Poehlmann, Flavio R; Cappelli, Mark A; Rieker, Gregory B

    2010-12-01

    Measurements are presented of the time-dependent current distribution inside a coaxial electromagnetic plasma gun. The measurements are carried out using an array of six axially distributed dual-Rogowski coils in a balanced circuit configuration. The radial current distributions indicate that operation in the gas-puff mode, i.e., the mode in which the electrode voltage is applied before injection of the gas, results in a stationary ionization front consistent with the presence of a plasma deflagration. The effects of varying the bank capacitance, transmission line inductance, and applied electrode voltage were studied over the range from 14 to 112 μF, 50 to 200 nH, and 1 to 3 kV, respectively.

  1. Parametric study on thermal performance of horizontal earth pipe cooling system in summer

    International Nuclear Information System (INIS)

    Ahmed, S.F.; Amanullah, M.T.O.; Khan, M.M.K.; Rasul, M.G.; Hassan, N.M.S.

    2016-01-01

    Highlights: • Horizontal earth pipe cooling (HEPC) performance was investigated by a parametric study. • A thermal model was developed using FLUENT for the parametric study. • Air velocity, pipe length and pipe diameter showed noticeable impact on HEPC performance. • Pipe length greatly influenced the HEPC performance compared to other parameters. - Abstract: Rational use of energy and its associated greenhouse gas emissions has become a key issue for a sustainable environment and economy. A substantial amount of energy is consumed by today’s buildings which are accountable for about 40% of the global energy consumption. There are on-going researches in order to overcome these and find new techniques through energy efficient measures. Passive air cooling of earth pipe cooling technique is one of those which can save energy in buildings with no greenhouse gas emissions. The performance of the earth pipe cooling system is mainly affected by the parameters, namely air velocity, pipe length, pipe diameter, pipe material, and pipe depth. This paper investigates the impact of these parameters on thermal performance of the horizontal earth pipe cooling system in a hot humid subtropical climate at Rockhampton, Australia. For the parametric investigation, a thermal model was developed for the horizontal earth pipe cooling system using the simulation program, FLUENT 15.0. Results showed a significant effect for air velocity, pipe length, and pipe diameter on the earth pipe cooling performance, where the pipe length dominated the other parameters.

  2. Significance of residual stress on fatigue properties of welded pipes

    International Nuclear Information System (INIS)

    Ohta, A.; Maeda, Y.; Kanao, M.

    1984-01-01

    The mean stress effect on the fatigue properties of two kinds of welded pipes was investigated in cantilever bending. The fatigue strength changed with the mean stress on fillet welded pipes, but did not change on butt welded pipes. The fatigue crack initiated from the toe of weld on the outer surface of fillet welded pipes and from the undercut on the inner surface of butt welded pipes. The measurement of the fatigue crack propagation rate and the residual stress distribution through the thickness of pipe revealed that the difference in the fatigue properties between fillet and butt welded pipes arose from the weld-induced residual stress, tension on the inner surface and compression on the outer surface. It is suggested that the production of compressive residual stress along the inner surface would be an effective means for improving the fatigue strength of butt welded pipes. (author)

  3. Distribution and origin of groundwater methane in the Wattenberg oil and gas field of northern Colorado.

    Science.gov (United States)

    Li, Huishu; Carlson, Kenneth H

    2014-01-01

    Public concerns over potential environmental contamination associated with oil and gas well drilling and fracturing in the Wattenberg field in northeast Colorado are increasing. One of the issues of concern is the migration of oil, gas, or produced water to a groundwater aquifer resulting in contamination of drinking water. Since methane is the major component of natural gas and it can be dissolved and transported with groundwater, stray gas in aquifers has elicited attention. The initial step toward understanding the environmental impacts of oil and gas activities, such as well drilling and fracturing, is to determine the occurrence, where it is and where it came from. In this study, groundwater methane data that has been collected in response to a relatively new regulation in Colorado is analyzed. Dissolved methane was detected in 78% of groundwater wells with an average concentration of 4.0 mg/L and a range of 0-37.1 mg/L. Greater than 95% of the methane found in groundwater wells was classified as having a microbial origin, and there was minimal overlap between the C and H isotopic characterization of the produced gas and dissolved methane measured in the aquifer. Neither density of oil/gas wells nor distance to oil/gas wells had a significant impact on methane concentration suggesting other important factors were influencing methane generation and distribution. Thermogenic methane was detected in two aquifer wells indicating a potential contamination pathway from the producing formation, but microbial-origin gas was by far the predominant source of dissolved methane in the Wattenberg field.

  4. Further comprehension of natural gas accumulation, distribution, and prediction prospects in China

    Directory of Open Access Journals (Sweden)

    Jun Li

    2017-06-01

    Full Text Available In-depth research reveals that the natural gas accumulation and distribution are characterized by cycle, sequence, equilibrium, traceability, and multi-stage. To be specific, every geotectonic cycle represents a gas reservoir forming system where natural gas is generated, migrated, accumulated, and formed into a reservoir in a certain play. Essentially, hydrocarbon accumulation occurs when migration force and resistance reach an equilibrium. In this situation, the closer to the source rock, the higher the accumulation efficiency is. Historically, reservoirs were formed in multiple phases. Moreover, zones in source rocks and adjacent to source rocks, unconformity belts, and faulted anticline belts are favorable areas to finding large gas fields. Apart from the common unconformity belts and faulted anticline belts, in-source and near-source zones should be considered as critical targets for future exploration. Subsequent exploration should focus on Upper Palaeozoic in the southeastern Ordos Basin, Triassic in southwestern Sichuan Basin, Jurassic in the northern section of the Kuqa Depression and other zones where no great breakthroughs have been made. Keywords: Large gas field, Distribution characteristics, Potential zone, Prospect

  5. Designing better methane mitigation policies: the challenge of distributed small sources in the natural gas sector

    Science.gov (United States)

    Ravikumar, Arvind P.; Brandt, Adam R.

    2017-04-01

    Methane—a short-lived and potent greenhouse gas—presents a unique challenge: it is emitted from a large number of highly distributed and diffuse sources. In this regard, the United States’ Environmental Protection Agency (EPA) has recommended periodic leak detection and repair surveys at oil and gas facilities using optical gas imaging technology. This regulation requires an operator to fix all detected leaks within a set time period. Whether such ‘find-all-fix-all’ policies are effective depends on significant uncertainties in the character of emissions. In this work, we systematically analyze the effect of facility-related and mitigation-related uncertainties on regulation effectiveness. Drawing from multiple publicly-available datasets, we find that: (1) highly-skewed leak-size distributions strongly influence emissions reduction potential; (2) variations in emissions estimates across facilities leads to large variability in mitigation effectiveness; (3) emissions reductions from optical gas imaging-based leak detection programs can range from 15% to over 70%; and (4) while implementation costs are uniformly lower than EPA estimates, benefits from saved gas are highly variable. Combining empirical evidence with model results, we propose four policy options for effective methane mitigation: performance-oriented targets for accelerated emission reductions, flexible policy mechanisms to account for regional variation, technology-agnostic regulations to encourage adoption of the most cost-effective measures, and coordination with other greenhouse gas mitigation policies to reduce unintended spillover effects.

  6. The effect of nuclear gas distribution on the mass determination of supermassive black holes

    Science.gov (United States)

    Mejía-Restrepo, J. E.; Lira, P.; Netzer, H.; Trakhtenbrot, B.; Capellupo, D. M.

    2018-01-01

    Supermassive black holes reside in the nuclei of most galaxies. During their active episodes, black holes are powered by accretion discs where gravitational energy is converted into radiation1. Accurately determining black hole masses is key to understand how the population evolves over time and how the black holes relate to their host galaxies2-4. Beyond the local universe, z ≳ 0.2, the mass is commonly estimated assuming a virialized motion of gas in the close vicinity of the active black holes, traced through broad emission lines5,6. However, this procedure has uncertainties associated with the unknown distribution of the gas clouds. Here, we show that the black hole masses derived from the properties of the accretion disk and virial mass estimates differ by a factor that is inversely proportional to the width of the broad emission lines. This leads to virial mass misestimations up to a factor of six. Our results suggest that a planar gas distribution that is inclined with respect to the line of sight may account for this effect. However, radiation pressure effects on the distribution of gas can also reproduce our results. Regardless of the physical origin, our findings contribute to mitigating the uncertainties in current black hole mass estimations and, in turn, will help us to better understand the evolution of distant supermassive black holes and their host galaxies.

  7. Post mortem CT of intrahepatic gas distribution in twenty-seven victims of a flood: Patterns and timing.

    Science.gov (United States)

    Sapienza, Daniela; Bottari, Antonio; Gualniera, Patrizia; Asmundo, Alessio; Perri, Fabrizio; Gaeta, Michele

    2017-11-01

    We reported the results of post mortem computed tomography of the liver in 27 subjects dead simultaneously during a flood. The aim of our work was to identify the different patterns of post mortem intrahepatic gas distribution and the timing of its appearance. Although post mortem CT is the method of choice for the evaluation of gas distribution, controversies exist about the first site of appearance of intrahepatic gas (portal veins versus hepatic veins) as well as the timing and steps of intrahepatic gas spreading. In each subject we performed thin slice CT scanner (Somatom Definition, Siemens) and post processing of native CT images with Minimum Intensity Projection technique. Our results show that the first site of appearance of intrahepatic gas is portal veins. Gas in hepatic veins was never seen without the presence of the gas in portal vein. Gaseous cysts in hepatic parenchyma represent a further and usually more tardive pattern of intrahepatic gas distribution. In addition, we demonstrated that differences in timing of gas spreading was statistically significative for exclusive presence of portal veins gas before 48h as well as for complete substitution of hepatic parenchyma by cysts 64h after death. In conclusion, our work shows that the CT study of postmortem intrahepatic gas distribution could be a useful complementary tool both in demonstrating the mechanism of intrahepatic gas spreading and in estimating post mortem interval. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Central Appalachian basin natural gas database: distribution, composition, and origin of natural gases

    Science.gov (United States)

    Román Colón, Yomayra A.; Ruppert, Leslie F.

    2015-01-01

    The U.S. Geological Survey (USGS) has compiled a database consisting of three worksheets of central Appalachian basin natural gas analyses and isotopic compositions from published and unpublished sources of 1,282 gas samples from Kentucky, Maryland, New York, Ohio, Pennsylvania, Tennessee, Virginia, and West Virginia. The database includes field and reservoir names, well and State identification number, selected geologic reservoir properties, and the composition of natural gases (methane; ethane; propane; butane, iso-butane [i-butane]; normal butane [n-butane]; iso-pentane [i-pentane]; normal pentane [n-pentane]; cyclohexane, and hexanes). In the first worksheet, location and American Petroleum Institute (API) numbers from public or published sources are provided for 1,231 of the 1,282 gas samples. A second worksheet of 186 gas samples was compiled from published sources and augmented with public location information and contains carbon, hydrogen, and nitrogen isotopic measurements of natural gas. The third worksheet is a key for all abbreviations in the database. The database can be used to better constrain the stratigraphic distribution, composition, and origin of natural gas in the central Appalachian basin.

  9. Field experience with a novel pipe protection and monitoring system for large offshore pipeline construction projects

    Energy Technology Data Exchange (ETDEWEB)

    Magerstaedt, Michael; Blitz, Gunther [ROSEN Swiss AG, Stans (Switzerland); Sabido, Carlos E. [ROSEN Technology and Research Center, Lingen (Germany)

    2012-07-01

    For pipe joints stored during large-scale offshore pipeline construction projects, corrosion protection as well as protection from physical damage of pipelines is very important. Integrity Management does not just start with the operation of a pipeline. In the past, with the much lower risks and cost at stake in on shore constriction, this factor was often overlooked. Sometimes, newly laid pipelines failed upon hydrostatic testing or even during operation. Causes were corrosion or damage the pipe joints took before pipeline laying. For offshore projects, the cost and consequences associated with such failures are orders of magnitude higher and must be avoided by all means. Within six months from the conception of the idea, a system was developed and deployed that protected (and in part still protects) a large number of pipe joints used in a European offshore gas pipeline project more than 2000 km. The pipe joints were physically protected from corrosion, interior contamination, and condensation. At the same time, the system provided real-time monitoring of more than 100'000 pipe joints stored at 5 storage yards distributed over 3 countries with distances of more than 1200 km apart from each other. Every single joint was identified with its location and status at every time during the storage period. Any third-party interference was transmitted to a central control room in real time as well. Protection of the pipe joints was provided vs.: corrosion of pipe joint end cutbacks exposed to the maritime climate for up to 2 years; contamination of the pipe interior by: foreign material, dirt, water, ice, animals. Third party damage to the pipe joints; damage to the protection system or to the transmission network; fire; theft of pipe joints or other equipment. System features were: modular pipe caps that, protect the pipe interior, cover both inner and outer cutback, allow ventilation of the pipe interior, continuously monitor each pipe joint for third party damage

  10. Pipe-to-pipe impact program

    International Nuclear Information System (INIS)

    Alzheimer, J.M.; Bampton, M.C.C.; Friley, J.R.; Simonen, F.A.

    1984-06-01

    This report documents the tests and analyses performed as part of the Pipe-to-Pipe Impact (PTPI) Program at the Pacific Northwest Laboratory. This work was performed to assist the NRC in making licensing decisions regarding pipe-to-pipe impact events following postulated breaks in high energy fluid system piping. The report scope encompasses work conducted from the program's start through the completion of the initial hot oil tests. The test equipment, procedures, and results are described, as are analytic studies of failure potential and data correlation. Because the PTPI Program is only partially completed, the total significance of the current test results cannot yet be accurately assessed. Therefore, although trends in the data are discussed, final conclusions and recommendations will be possible only after the completion of the program, which is scheduled to end in FY 1984

  11. The ionization state in a gas with a non-Maxwellian electron distribution

    Science.gov (United States)

    Owocki, S. P.; Scudder, J. D.

    1981-01-01

    The inferred degree of ionization of a gas is often used in astrophysics as a diagnostic of the gas temperature. In the solar transition region and corona, in the outer atmospheres of cool stars, and in some portions of the interstellar medium), photoionization can be neglected, and the ionization state is fixed by the balance between ion-electron collisional ionization and dielectronic and/or radiative recombination. Under these conditions, higher degrees of ionization result from higher energy ion-electron collisions which are common in a high temperature gas. Actually, ionization occurs through collisions with electrons that have kinetic energies greater than the ionization potential of the given ion, and so the ionization rate depends on to the number of such high-energy electrons in the tail of the electron velocity distribution. High-velocity electrons move across large distances between effective coulomb collisions, and, in a strong temperature or density gradient, the tail can be overpopulated relative to Maxwell-Boltzmann distribution of equivalent energy density. Thus, the ionization rate can also be greatly increased. These effects for a parameterized form of the electron distribution function with an enhanced high-velocity tail, namely the kappa distribution are illustrated.

  12. Development of an inspection robot for small diameter gas distribution mains

    NARCIS (Netherlands)

    Dertien, Edwin Christian; Stramigioli, Stefano; Pulles, Kees

    2011-01-01

    This paper discusses the design of a mechanical structure of a miniature pipe inspection robot capable of moving through very small pipes (down to 41 mm inner diameter). The requirement to negotiate bends, T-joints and steep inclinations pose another set of strict design constraints. The proposed

  13. Basic maneuvers for an inspection robot for small diameter gas distribution mains

    NARCIS (Netherlands)

    Dertien, Edwin Christian; Stramigioli, Stefano

    2011-01-01

    This video shows the design of a mechanical structure of a miniature pipe inspection robot (MPR) capable of moving trough very small pipes (up to 41 mm inner diameter) as well as a wide range of diameters (63 to 125 mm outer diameter). The requirement to negotiate bends, T-joints and steep

  14. Government information report to the parliament. The gas distribution in France; Rapport d'information du gouvernement au parlement. La desserte en gaz du territoire francais

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-11-01

    This report evaluates the gas distribution state in France and presents the forecasts of the gas energy use development by the gas utilities users. In this framework the following points are presented: the juridical aspects of the gas distribution, the national plan of distribution, the new legislation occurring from the gas market deregulation and some statistical data on the gas use, consumption and demand in France. (A.L.B.)

  15. Shallow gas seismic structures: forms and distribution on Santa Catarina Island, Southern Brazil

    Directory of Open Access Journals (Sweden)

    Antonio Henrique da Fontoura Klein

    Full Text Available Abstract This paper presents the spatial distribution of shallow gas structures and classifies them on the basis of two different data sets of CHIRP seismic records, one from the Conceição Lagoon (CL and the other from North Bay (NB, both on Santa Catarina Island, Southern Brazil. Side scan sonar data from the CL were used to facilitate the understanding. The sub bottom (SB seismic data were processed and interpreted by means of the SeisPrho software, the side scan sonar (SSS data by SonarWiz5 software and the spatial extension being measured with the help of GIS. The shallow gas structures were defined in accordance with their shapes in the seismic recordings (echo-character. At the CL, shallow gas accumulations were found in the form of seepages and features presenting shallow gas structures between the surface and 8.20 ms (around 12.3 m. Accumulations of gas were found in the form of Acoustic Blanking with Acoustic Plume, and also Black Shadows. Pockmarks were found on the lagoon floor and associated with gas seepages (average size diameter 0.97 ± 0.19 m and density from 54 to 242 units per 50 m2. In the NB three types of shallow gas features were found in the seismic profile, namely Acoustic Blanking, Turbidity Pinnacles and Intra-sedimentary plumes. The depth varied from the surface to 12.10 ms (around 18.15 m. In both environments, the gas is escaping from the sediment into the water column. The Pockmarks in the CL and the Acoustic Plume features and sediment rich in total sulfur in the NB validate these findings.

  16. Productivity and quality improvements. A report on cost management in gas distribution at the energy distribution company Amsterdam (Energie Noord West Amsterdam NV)

    International Nuclear Information System (INIS)

    Bosch, T.

    1997-01-01

    In a more competitive times traditional and technical industries like gas distribution have to change. They have to commercialize. A way to support this transition is to introduce an activity based cost control system (ABC) with proper delegation of financial responsibilities. This report is about the history of cost management in Amsterdam and the introduction of ABC in our distribution company. The message to other gas distributors is that introducing some form of ABC can be worth wile in the future and is probably inescapable because of growing competition. In the end gas distribution will probably turn out to be one of the few places where money can be earned in the entire gas trade. Not by increasing distribution prices, but by decreasing distribution costs and strategic investments. (au)

  17. Distribution of Iodine and Its Geochronological Implications for Gas Field Brine in Japan

    Science.gov (United States)

    Tomaru, H.; Hirose, N.; Miyazato, S.

    2017-12-01

    Global distribution of iodine is very heterogeneous in location and chemical species; 65% of total iodine is produced in Chile as solid nitrate (e.g. caliche) and 30% in Japan as solute mainly in gas field brine. In the latter case, because iodine has a close association with marine organic materials such as algae, iodine had been liberated into the surrounding aqueous phase during the generation of oil and gas and traveled together with oil/gas to the current deposit. The distribution of iodine therefore reflects the environments of accumulation and secondary migration of iodine during its diagenetic processes. Here we present the concentrations of total iodine (127-I) and a long-lived radioisotope (129-I) in gas field brines in Japan to understand the behavior of iodine in response to the development of present geological setting including oil field in terms of its geochronological signals using 129-I. The concentrations of iodine dissolved in gas field brines and hot/cold springs in nearby areas are relatively high compared with the seawater composition, although the chloride concentrations are lower than the seawater. This is due to the delivery of iodine from organic-rich sediments into the current deposits. The 129-I has decayed since the deposition of iodine-rich organic materials from the seawater following the standard decay curve, however, the129-I concentrations are relatively low compared with the age of host sediments of the fluids, which indicates iodine has derived secondary from old sediments responsible for the generation of gas. The 129-I and halogen composition also indicate these fluids mix with pre-anthropogenic seawater during the migration. These results characterize the history of long-term migration of iodine in organic-rich marine system.

  18. Gas Hydrate Formation Probability Distributions: The Effect of Shear and Comparisons with Nucleation Theory.

    Science.gov (United States)

    May, Eric F; Lim, Vincent W; Metaxas, Peter J; Du, Jianwei; Stanwix, Paul L; Rowland, Darren; Johns, Michael L; Haandrikman, Gert; Crosby, Daniel; Aman, Zachary M

    2018-03-13

    Gas hydrate formation is a stochastic phenomenon of considerable significance for any risk-based approach to flow assurance in the oil and gas industry. In principle, well-established results from nucleation theory offer the prospect of predictive models for hydrate formation probability in industrial production systems. In practice, however, heuristics are relied on when estimating formation risk for a given flowline subcooling or when quantifying kinetic hydrate inhibitor (KHI) performance. Here, we present statistically significant measurements of formation probability distributions for natural gas hydrate systems under shear, which are quantitatively compared with theoretical predictions. Distributions with over 100 points were generated using low-mass, Peltier-cooled pressure cells, cycled in temperature between 40 and -5 °C at up to 2 K·min -1 and analyzed with robust algorithms that automatically identify hydrate formation and initial growth rates from dynamic pressure data. The application of shear had a significant influence on the measured distributions: at 700 rpm mass-transfer limitations were minimal, as demonstrated by the kinetic growth rates observed. The formation probability distributions measured at this shear rate had mean subcoolings consistent with theoretical predictions and steel-hydrate-water contact angles of 14-26°. However, the experimental distributions were substantially wider than predicted, suggesting that phenomena acting on macroscopic length scales are responsible for much of the observed stochastic formation. Performance tests of a KHI provided new insights into how such chemicals can reduce the risk of hydrate blockage in flowlines. Our data demonstrate that the KHI not only reduces the probability of formation (by both shifting and sharpening the distribution) but also reduces hydrate growth rates by a factor of 2.

  19. On the equilibrium distribution of the elements in the gas in the Coma cluster

    Science.gov (United States)

    Abramopoulos, F.; Chanan, G. A.; Ku, W. H.-M.

    1981-01-01

    The equilibrium distribution of the elements for the case of an isothermal plasma in a gravitational potential well is given governing equations and a rapidly converging iterative procedure for their solution. Results are applied to the intracluster gas in clusters of galaxies, and implications are identified for the controversy as to whether iron nuclei settle out in the cluster core, and with respect to the interpretation of distribution size and shape for continuum X-ray emission from clusters. A model for the Coma cluster is considered in which the intracluster gas is in equilibrium and partially processed. It is found that this model can account for the angular dependence of the continuum X-ray emission from Coma, as determined by Einstein Observatory observations, at least as well as the uniform composition model.

  20. Natural gas transmission and distribution model of the National Energy Modeling System

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-02-01

    The Natural Gas Transmission and Distribution Model (NGTDM) is the component of the National Energy Modeling System (NEMS) that is used to represent the domestic natural gas transmission and distribution system. NEMS was developed in the Office of Integrated Analysis and Forecasting of the Energy Information Administration (EIA). NEMS is the third in a series of computer-based, midterm energy modeling systems used since 1974 by the EIA and its predecessor, the Federal Energy Administration, to analyze domestic energy-economy markets and develop projections. From 1982 through 1993, the Intermediate Future Forecasting System (IFFS) was used by the EIA for its analyses, and the Gas Analysis Modeling System (GAMS) was used within IFFS to represent natural gas markets. Prior to 1982, the Midterm Energy Forecasting System (MEFS), also referred to as the Project Independence Evaluation System (PIES), was employed. NEMS was developed to enhance and update EIA`s modeling capability by internally incorporating models of energy markets that had previously been analyzed off-line. In addition, greater structural detail in NEMS permits the analysis of a broader range of energy issues. The time horizon of NEMS is the midterm period (i.e., through 2015). In order to represent the regional differences in energy markets, the component models of NEMS function at regional levels appropriate for the markets represented, with subsequent aggregation/disaggregation to the Census Division level for reporting purposes.

  1. Natural gas transmission and distribution model of the National Energy Modeling System

    International Nuclear Information System (INIS)

    1997-02-01

    The Natural Gas Transmission and Distribution Model (NGTDM) is the component of the National Energy Modeling System (NEMS) that is used to represent the domestic natural gas transmission and distribution system. NEMS was developed in the Office of Integrated Analysis and Forecasting of the Energy Information Administration (EIA). NEMS is the third in a series of computer-based, midterm energy modeling systems used since 1974 by the EIA and its predecessor, the Federal Energy Administration, to analyze domestic energy-economy markets and develop projections. From 1982 through 1993, the Intermediate Future Forecasting System (IFFS) was used by the EIA for its analyses, and the Gas Analysis Modeling System (GAMS) was used within IFFS to represent natural gas markets. Prior to 1982, the Midterm Energy Forecasting System (MEFS), also referred to as the Project Independence Evaluation System (PIES), was employed. NEMS was developed to enhance and update EIA's modeling capability by internally incorporating models of energy markets that had previously been analyzed off-line. In addition, greater structural detail in NEMS permits the analysis of a broader range of energy issues. The time horizon of NEMS is the midterm period (i.e., through 2015). In order to represent the regional differences in energy markets, the component models of NEMS function at regional levels appropriate for the markets represented, with subsequent aggregation/disaggregation to the Census Division level for reporting purposes

  2. Fabrication of gas impervious edge seal for a bipolar gas distribution assembly for use in a fuel cell

    Science.gov (United States)

    Kaufman, Arthur; Werth, John

    1986-01-01

    A bipolar gas reactant distribution assembly for use in a fuel cell is disclosed, the assembly having a solid edge seal to prevent leakage of gaseous reactants wherein a pair of porous plates are provided with peripheral slits generally parallel to, and spaced apart from two edges of the plate, the slit being filled with a solid, fusible, gas impervious edge sealing compound. The plates are assembled with opposite faces adjacent one another with a layer of a fusible sealant material therebetween the slits in the individual plates being approximately perpendicular to one another. The plates are bonded to each other by the simultaneous application of heat and pressure to cause a redistribution of the sealant into the pores of the adjacent plate surfaces and to cause the edge sealing compound to flow and impregnate the region of the plates adjacent the slits and comingle with the sealant layer material to form a continuous layer of sealant along the edges of the assembled plates.

  3. Life Cycle Energy Consumption and Greenhouse Gas Emissions Analysis of Natural Gas-Based Distributed Generation Projects in China

    Directory of Open Access Journals (Sweden)

    Hansi Liu

    2017-10-01

    Full Text Available In this paper, we used the life-cycle analysis (LCA method to evaluate the energy consumption and greenhouse gas (GHG emissions of natural gas (NG distributed generation (DG projects in China. We took the China Resources Snow Breweries (CRSB NG DG project in Sichuan province of China as a base scenario and compared its life cycle energy consumption and GHG emissions performance against five further scenarios. We found the CRSB DG project (all energy input is NG can reduce GHG emissions by 22%, but increase energy consumption by 12% relative to the scenario, using coal combined with grid electricity as an energy input. The LCA also indicated that the CRSB project can save 24% of energy and reduce GHG emissions by 48% relative to the all-coal scenario. The studied NG-based DG project presents major GHG emissions reduction advantages over the traditional centralized energy system. Moreover, this reduction of energy consumption and GHG emissions can be expanded if the extra electricity from the DG project can be supplied to the public grid. The action of combining renewable energy into the NG DG system can also strengthen the dual merit of energy conservation and GHG emissions reduction. The marginal CO2 abatement cost of the studied project is about 51 USD/ton CO2 equivalent, which is relatively low. Policymakers are recommended to support NG DG technology development and application in China and globally to boost NG utilization and control GHG emissions.

  4. Thermal Distribution in Axial-Flow Fixed Bed with Flowing Gas

    OpenAIRE

    Kun Lei; Hongfang Ma; Haitao Zhang; Weiyong Ying; Dingye Fang

    2013-01-01

    This paper reported an experimental research of steady-state heat transfer behaviour of a gas flowing through a fixed bed under the different operating conditions. Studies had been carried out in a fixed-bed packed methanol synthesis catalyst percolated by air at appropriate flow rate. Both radial and axial direction temperature distribution had been investigated under the different operating conditions. The effects of operating conditions including the reactor inlet air ...

  5. Transition in Gas Turbine Engine Control System Architecture: Modular, Distributed, Embedded

    Science.gov (United States)

    2009-08-01

    er ace • Similar to the way EHSV interfaces are controlled today (ARP490) • Bolt/connector interfaces should be standardized St d d f ti lit l l i ti...AFRL-RZ-WP-TP-2009-2179 TRANSITION IN GAS TURBINE ENGINE CONTROL SYSTEM ARCHITECTURE: MODULAR, DISTRIBUTED, EMBEDDED (POSTPRINT) Bruce...with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS

  6. Ventilation distribution in rats: Part I--The effect of gas composition as measured with electrical impedance tomography.

    Science.gov (United States)

    Dunster, Kimble R; Friese, Marlies; Fraser, John F; Cowin, Gary J; Schibler, Andreas

    2012-09-04

    The measurement of ventilation distribution is currently performed using inhaled tracer gases for multiple breath inhalation studies or imaging techniques to quantify spatial gas distribution. Most tracer gases used for these studies have properties different from that of air. The effect of gas density on regional ventilation distribution has not been studied. This study aimed to measure the effect of gas density on regional ventilation distribution. Ventilation distribution was measured in seven rats using electrical impedance tomography (EIT) in supine, prone, left and right lateral positions while being mechanically ventilated with either air, heliox (30% oxygen, 70% helium) or sulfur hexafluoride (20% SF6, 20% oxygen, 60% air). The effect of gas density on regional ventilation distribution was assessed. Gas density did not impact on regional ventilation distribution. The non-dependent lung was better ventilated in all four body positions. Gas density had no further impact on regional filling characteristics. The filling characteristics followed an anatomical pattern with the anterior and left lung showing a greater impedance change during the initial phase of the inspiration. It was shown that gas density did not impact on convection dependent ventilation distribution in rats measured with EIT.

  7. Probing the regional distribution of pulmonary gas exchange through single-breath gas- and dissolved-phase 129Xe MR imaging.

    Science.gov (United States)

    Kaushik, S Sivaram; Freeman, Matthew S; Cleveland, Zackary I; Davies, John; Stiles, Jane; Virgincar, Rohan S; Robertson, Scott H; He, Mu; Kelly, Kevin T; Foster, W Michael; McAdams, H Page; Driehuys, Bastiaan

    2013-09-01

    Although some central aspects of pulmonary function (ventilation and perfusion) are known to be heterogeneous, the distribution of diffusive gas exchange remains poorly characterized. A solution is offered by hyperpolarized 129Xe magnetic resonance (MR) imaging, because this gas can be separately detected in the lung's air spaces and dissolved in its tissues. Early dissolved-phase 129Xe images exhibited intensity gradients that favored the dependent lung. To quantitatively corroborate this finding, we developed an interleaved, three-dimensional radial sequence to image the gaseous and dissolved 129Xe distributions in the same breath. These images were normalized and divided to calculate "129Xe gas-transfer" maps. We hypothesized that, for healthy volunteers, 129Xe gas-transfer maps would retain the previously observed posture-dependent gradients. This was tested in nine subjects: when the subjects were supine, 129Xe gas transfer exhibited a posterior-anterior gradient of -2.00 ± 0.74%/cm; when the subjects were prone, the gradient reversed to 1.94 ± 1.14%/cm (P gas-transfer maps also exhibited significant heterogeneity, as measured by the coefficient of variation, that correlated with subject total lung capacity (r = 0.77, P = 0.015). Gas-transfer intensity varied nonmonotonically with slice position and increased in slices proximal to the main pulmonary arteries. Despite substantial heterogeneity, the mean gas transfer for all subjects was 1.00 ± 0.01 while supine and 1.01 ± 0.01 while prone (P = 0.25), indicating good "matching" between gas- and dissolved-phase distributions. This study demonstrates that single-breath gas- and dissolved-phase 129Xe MR imaging yields 129Xe gas-transfer maps that are sensitive to altered gas exchange caused by differences in lung inflation and posture.

  8. MULTI-CRITERIA EVALUATION OF THE EXPANSION OF NATURAL GAS DISTRIBUTION NETWORK BY THE URBAN DYNAMICS

    Directory of Open Access Journals (Sweden)

    Vanessa M. Massara

    2010-01-01

    Full Text Available The objective of this work is to analyze the expansion of the infrastructure of natural gas distribution, identifying priorities from large metropolis using the energy planning based on urban design tools like urban dynamics and techniques like AHP (analytic hierarchy process. The methodology proposed uses matrices considering the relations between the concept of urban dynamics, quality of life and the possibilities of natural gas displacing other energy forms. The matrices are made up of information about social and urban development, costs of establishing the infrastructure and projections of the consumption potential in various sectors. Relating the consumption to urban development parameters and the real estate future of the areas in study, the methodology allows indicating for each district, the viability of implementing a gas network. As conclusion, the model presents the integration between the cities profile and the natural gas use, by means of a growth natural gas on districts of São Paulo City as a specific case study.

  9. Design guideline to prevent the pipe rupture by radiolysis gases in BWR steam piping

    International Nuclear Information System (INIS)

    Inagaki, T.; Miyagawa, M.; Ota, T.; Sato, T.; Sakata, K.

    2009-01-01

    In late 2001, pipe rupture accidents due to fast combustion of radiolysis gas occurred in Japan and elsewhere's BWR power plants. TENPES began to set up the guideline as action to such a new problem to prevent accumulation and combustion of radiolysis gas in BWR steam piping. And then, the first edition of guideline was published in October 2005. Afterwards, the experimental study about combustion/detonation of radiolysis gas have been continued. And in March 2007, TENPES published a revised edition of the guideline. This is the report of the revised edition of that guideline. According to this guideline, it became possible to design BWR's steam piping to prevent accumulation of radiolysis gas. (author)

  10. The open access and the natural gas ducts: transport and distribution; O livre acesso e os dutos de gas natural: transporte e distribuicao

    Energy Technology Data Exchange (ETDEWEB)

    Siqueira, Mariana de; Xavier, Yanko Marcius de Alencar [Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil)

    2008-07-01

    The present research, attempting for the economic relevance of the natural gas sector, for the lack of a law that disciplines it and, still, for the structural question of the natural gas ducts activities; it analyzes, in a comparative way, the monopoly of the natural gas ducts activities and the mechanisms of competition chosen to brighten up it: the open access and the by pas. The transport and the distribution of the natural gas are really similar, but the ways to insert the competition in its areas are not. (author)

  11. Uncertainty quantification of aeroacoustic power sources in corrugated pipes

    NARCIS (Netherlands)

    Swamy, M.; Shoeibi Omrani, P.; González Díez, N.

    2015-01-01

    Gas transport in corrugated pipes often exhibit whistling behavior, due to periodic flow-induced pulsations generated in the pipe cavities. These aero-acoustic sources are strongly dependent on the geometrical dimensions and features of the cavities. As a result, uncertainties in the exact shape and

  12. Sills, aureoles and pipes in the Karoo Basin, South Africa, as triggers for Early Jurassic environmental changes

    Science.gov (United States)

    Svensen, Henrik H.; Planke, Sverre; Silkoset, Petter; Hammer, Øyvind; Iyer, Karthik; Schmid, Dani W.; Chevallier, Luc

    2017-04-01

    Most of the Large Igneous Provinces (LIPs) formed during the last 260 million years are associated with climatic change, oceanic anoxia, or extinctions in marine and terrestrial environments. Current hypotheses involve A) degassing of carbon either from oceans or shallow sea-bed reservoirs, B) carbon and sulfur degassing from flood basalts, C) degassing from sedimentary basins heavily intruded by LIPs. Here we present new data on gas generation and degassing from the Karoo LIP, based on fieldwork, borehole studies (geochemistry, petrography), and thermal modeling. Our data expand and corroborate earlier work on the sub-volcanic processes in the Karoo Basin. We show that 1) hundreds of breccia pipes are rooted in Early Jurassic sill complexes and contact aureoles within the organic-rich Ecca Group, 2) statistical analyses reveal a fractal distribution of pipes and that they are overdispersed at small scales (800 m), 3) contact aureoles show a reduction in organic matter content towards the sill contacts, reduced to zero in the nearest zones, producing more carbon gas compared to thermal model calculations, 4) we find up to 3 permil reduction in the d13C of the organic matter remaining in the aureoles, and finally 5) some pipes contain recent oil seeps. We conclude that the sill-pipe system released thermogenic gases to the Early Jurassic atmosphere and that the pipes may have acted as permanent fluid flow pathways.

  13. Numerical solutions of ideal quantum gas dynamical flows governed by semiclassical ellipsoidal-statistical distribution.

    Science.gov (United States)

    Yang, Jaw-Yen; Yan, Chih-Yuan; Diaz, Manuel; Huang, Juan-Chen; Li, Zhihui; Zhang, Hanxin

    2014-01-08

    The ideal quantum gas dynamics as manifested by the semiclassical ellipsoidal-statistical (ES) equilibrium distribution derived in Wu et al. (Wu et al . 2012 Proc. R. Soc. A 468 , 1799-1823 (doi:10.1098/rspa.2011.0673)) is numerically studied for particles of three statistics. This anisotropic ES equilibrium distribution was derived using the maximum entropy principle and conserves the mass, momentum and energy, but differs from the standard Fermi-Dirac or Bose-Einstein distribution. The present numerical method combines the discrete velocity (or momentum) ordinate method in momentum space and the high-resolution shock-capturing method in physical space. A decoding procedure to obtain the necessary parameters for determining the ES distribution is also devised. Computations of two-dimensional Riemann problems are presented, and various contours of the quantities unique to this ES model are illustrated. The main flow features, such as shock waves, expansion waves and slip lines and their complex nonlinear interactions, are depicted and found to be consistent with existing calculations for a classical gas.

  14. Optimal Expansion Co-Planning of Reconfigurable Electricity and Natural Gas Distribution Systems Incorporating Energy Hubs

    Directory of Open Access Journals (Sweden)

    Xianzheng Zhou

    2017-01-01

    Full Text Available In a carbon-constrained world, natural gas with low emission intensity plays an important role in the energy consumption area. Energy consumers and distribution networks are linked via energy hubs. Meanwhile, reconfiguration that optimizes operational performance while maintaining a radial network topology is a worldwide technique in the electricity distribution system. To improve the overall efficiency of energy infrastructure, the expansion of electricity distribution lines and elements within energy hubs should be co-planned. In this paper, the co-planning process is modeled as a mixed integer quadratic programming problem to handle conflicting objectives simultaneously. We propose a novel model to identify the optimal co-expansion plan in terms of total cost. Operational factors including energy storages and reconfiguration are considered within the systems to serve electricity, cooling and heating loads. Reconfiguration and elements in energy hubs can avoid or defer new elements’ installation to minimize the investment cost, maintenance cost, operation cost, and interruption cost in the planning horizon. The proposed co-planning approach is verified on 3 and 12-node electricity and natural gas distribution systems coupled via energy hubs. Numerical results show the ability of our proposed expansion co-planning approach based on energy hub in meeting energy demand.

  15. Numerical solutions of ideal quantum gas dynamical flows governed by semiclassical ellipsoidal-statistical distribution

    Science.gov (United States)

    Yang, Jaw-Yen; Yan, Chih-Yuan; Diaz, Manuel; Huang, Juan-Chen; Li, Zhihui; Zhang, Hanxin

    2014-01-01

    The ideal quantum gas dynamics as manifested by the semiclassical ellipsoidal-statistical (ES) equilibrium distribution derived in Wu et al. (Wu et al. 2012 Proc. R. Soc. A 468, 1799–1823 (doi:10.1098/rspa.2011.0673)) is numerically studied for particles of three statistics. This anisotropic ES equilibrium distribution was derived using the maximum entropy principle and conserves the mass, momentum and energy, but differs from the standard Fermi–Dirac or Bose–Einstein distribution. The present numerical method combines the discrete velocity (or momentum) ordinate method in momentum space and the high-resolution shock-capturing method in physical space. A decoding procedure to obtain the necessary parameters for determining the ES distribution is also devised. Computations of two-dimensional Riemann problems are presented, and various contours of the quantities unique to this ES model are illustrated. The main flow features, such as shock waves, expansion waves and slip lines and their complex nonlinear interactions, are depicted and found to be consistent with existing calculations for a classical gas. PMID:24399919

  16. Investigations on the gas distribution phenomena inside the containment system of LWRs

    International Nuclear Information System (INIS)

    Manfredini, A.; Oriolo, F.; Villotti, A.

    1994-01-01

    The importance of mixing and distribution phenomena of hydrogen gas in the reactor safety is emphasised in the advanced reactor concepts, that heavily rely upon the passive cooling systems during a typical severe accident sequence. An advanced methodology for evaluating the temporal and spatial distribution of non condensable gases, including the simulation of buoyancy-driven flows and the effects of the various ESFs activation, in a multi-compartment containment system of a LWR is reviewed. The methodology employs an analogy technique with electrical networks to determine the convection flows among the containment compartments and evaluates, inside a single node, the profile of the vertical concentrations of steam and non condensable gases. The application of the proposed models to simulate the gas distribution phenomena occurring in the HDR E11.2, in the FIPLOC-F2 and in the NUPEC M-7-1 tests demonstrates the importance of these models providing information about local details and spatial distribution. The main results from the post-test analysis performed to simulate the thermal-hydraulic responses of the above mentioned experiments are presented and demonstrate the improvements and the reduction of the error band with respect to the experimental data. This methodology allows to perform a realistic prediction of severe accident sequence inside the containment system of the actual and advanced passive generation of LWRs. (author). 14 refs., 11 figs

  17. Towards an in-situ measurement of wave velocity in buried plastic water distribution pipes for the purposes of leak location

    Science.gov (United States)

    Almeida, Fabrício C. L.; Brennan, Michael J.; Joseph, Phillip F.; Dray, Simon; Whitfield, Stuart; Paschoalini, Amarildo T.

    2015-12-01

    Water companies are under constant pressure to ensure that water leakage is kept to a minimum. Leak noise correlators are often used to help find and locate leaks. These devices correlate acoustic or vibration signals from sensors which are placed either side the location of a suspected leak. The peak in the cross-correlation function of the measured signals gives the time difference between the arrival times of the leak noise at the sensors. To convert the time delay into a distance, the speed at which the leak noise propagates along the pipe (wave-speed) needs to be known. Often, this is estimated from historical wave-speed data measured on other pipes obtained at various times and under various conditions, or it is estimated from tables which are calculated using simple formula. Usually, the wave-speed is not measured directly at the time of the correlation measurement and is therefore potentially a source of significant error in the localisation of the leak. In this paper, a new method of measuring the wave-speed in-situ in the presence of a leak, that is robust and simple, is explored. Experiments were conducted on a bespoke large scale buried pipe test-rig, in which a leak was also induced in the pipe between the measurement positions to simulate a condition that is likely to occur in practice. It is shown that even in conditions where the signal to noise ratio is very poor, the wave-speed estimate calculated using the new method is less than 5% different from the best estimate of 387 m s-1.

  18. A generalized relationship for swirl decay in laminar pipe flow

    Indian Academy of Sciences (India)

    symbols are included for visual aid only; they do not represent the number of nodes used in the computations. The axial velocity distributions in the pipe for swirl number So = 1·0, Re = 1000 ... but its memory persists indefinitely. Figure 6 shows the decay of swirl along the pipe for different inlet tangential velocity distributions ...

  19. State of the art of pipe clamp analysis

    International Nuclear Information System (INIS)

    Fang, P.J.

    1984-01-01

    Various types of clamps are used as a component of piping support structures in nuclear power plants. The clamp is referred to as a nonintegral attachment to pipe in contrast to lugs which are integrally welded to the pipe wall. An analysis to determine the load capacity of a clamp is complicated by the fact that the distribution of contact stresses acting on the clamp-pipe interface is a nonlinearly dependent on the geometry of the clamp and pipe, clamping force preapplied to the clamp, and external loads. This paper reviews various methods of clamp analysis including both the closed-formed solutions and the finite element approach. While conventional two- and three-bolt clamps for a horizontal pipe run are emphasized, stiff clamps and riser clamps are also discussed. Finally, the potential effects of interaction between the clamp and pipe are evaluated. (Author) [pt

  20. The obstacles for the investments in natural gas distribution infrastructure in Brazil; Os obstaculos aos investimentos na rede de distribuicao de gas natural no Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Edmar Luiz Fagundes de; Bueno, Salua Saud; Selles, Vitor [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Inst. de Economia

    2004-07-01

    This paper analyses the main obstacles for the expansion of the Brazilian gas distribution pipelines infrastructure. The paper examines the evolution of investments in the gas chain and highlights the existence of an important unbalance between the level of investments in the upstream and transportation segments and the level of investment in the distribution network. It is clear that the level of investments in the distribution segment is not following the pace of expansion of the other segments. Given this conclusion, the paper examines the potential for increasing the level of investment in the distribution segment by augmenting the debt level of distribution companies. By analyzing the main distribution companies' financial statements, the paper shows that they there is room for an expansion in investments through financial leverage. Finally, the paper examines the main financing obstacles that impede the companies to increase their investment level. (author)

  1. The effect of gas double-dynamic on mass distribution in solid-state fermentation.

    Science.gov (United States)

    Chen, Hong-Zhang; Zhao, Zhi-Min; Li, Hong-Qiang

    2014-05-10

    The mass distribution regularity in substrate of solid-state fermentation (SSF) has rarely been reported due to the heterogeneity of solid medium and the lack of suitable instrument and method, which limited the comprehensive analysis and enhancement of the SSF performance. In this work, the distributions of water, biomass, and fermentation product in different medium depths of SSF were determined using near-infrared spectroscopy (NIRS) and the developed models. Based on the mass distribution regularity, the effects of gas double-dynamic on heat transfer, microbial growth and metabolism, and product distribution gradient were systematically investigated. Results indicated that the maximum temperature of substrate and the maximum carbon dioxide evolution rate (CER) were 39.5°C and 2.48mg/(hg) under static aeration solid-state fermentation (SASSF) and 33.9°C and 5.38mg/(hg) under gas double-dynamic solid-state fermentation (GDSSF), respectively, with the environmental temperature for fermentation of 30±1°C. The fermentation production (cellulase activity) ratios of the upper, middle, and lower levels were 1:0.90:0.78 at seventh day under SASSF and 1:0.95:0.89 at fifth day under GDSSF. Therefore, combined with NIRS analysis, gas double-dynamic could effectively strengthen the solid-state fermentation performance due to the enhancement of heat transfer, the stimulation of microbial metabolism and the increase of the homogeneity of fermentation products. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Impact of distributed and independent power generation on greenhouse gas emissions: Sri Lanka

    Energy Technology Data Exchange (ETDEWEB)

    Wijayatunga, P.D.C. [University of Moratuwa (Sri Lanka). Centre for Energy Studies; Fernando, W.J.L.S. [Sri Lanka Energy Managers Association, Colombo (Sri Lanka); Shrestha, R.M. [Asian Institute of Technology, Pathumthani (Thailand). Energy Program

    2004-12-01

    Sri Lanka has a hydropower dominated power system with approximately two thirds of its generation capacity based on large hydro plants. The remaining one third are based on oil fired thermal generation with varying technologies, such as oil steam, Diesel, gas turbines and combined cycle plants. A significant portion of this capacity is in operation as independent power plants (IPPs). In addition to these, Sri Lanka presently has about 40 MWs of mini-hydro plants, which are distributed in the highlands and their surrounding districts, mainly connected to the primary distribution system. Further, there are a few attempts to build fuel wood fired power plants of small capacities and connect them to the grid in various parts of the country. The study presented in this paper investigates the impact of these new developments in the power sector on the overall emissions and the greenhouse gas (GHG) emissions in particular. It examines the resulting changes to the emissions and costs in the event of developing the proposed coal power plant as an IPP under different investment and operational conditions. The paper also examines the impact on emissions with 80 MWs of distributed power in different capacities of wind, mini-hydro and wood fired power plants. It is concluded that grid connected, distributed power generation (DPG) reduces emissions, with only a marginal increase in overall costs, due to the reduction in transmission and distribution network losses that result from the distributed nature of generation. These reductions can be enhanced by opting for renewable energy based DPGS, as the case presented in the paper, and coupling them with demand side management measures. It is also concluded that there is no impact on overall emissions by the base load IPPs unless they are allowed to change over to different fuel types and technologies. (author)

  3. Transitory provisions on public gas distribution in the light of the Marzano law

    International Nuclear Information System (INIS)

    Vedaschi, Arianna

    2005-01-01

    The article begins by describing community law on public gas distribution service, then it examines legislative decree 164/2000( also called Letta Decree), which implements directive no. 98/30/CE. This directive reforms the gas sector and in particular it reforms the way gas is distributed. Art. 14 of the Letta Decree states that the distribution of natural gas shall be a public service, contractors shall be selected through a public tender and contracts shall be stipulate for a maximum of 12 years. Thus it is evident that the new model is radically different from the previous one. Before, the service was provided by the local authorities (either directly or through a long-term lease); now the new model aims at liberalizing the market by out sourcing gas distribution. Out sourcing is carried out through a public tender and for short periods of time. In order to allow a gradual transition from the old model to the new one, the Letta Decree provides for a transitory period articulated in various phases. This has the aim of guaranteeing a balance between the interest of local authorities, on one hand and the firms that distributed gas before the reform came into effect, on the other. The first part of the article focuses on interpretative problems that arose after law no. 239/2004 (so called Marzano law) was passed. In the second half it compares the different judicial interpretations concerning: a) duration of the transitory period; b) possibility of increasing duration as provided for by art. 15, par.7 of legislative decree 164/2000; c) efficacy of the abrogation of art. 15, par.8 of legislative decree 164/2000 and finally d) whether advanced redemption of the gas distribution service is still possible. With regards to the transitory period, the article compares judgement no. 111/2005 by the Administrative Tribunal of Lombardia, with judgement no. 6187/2005 delivered by the Sixth Section of the State Council. It then argues that the prohibition of concentration has

  4. A distribution planning model for natural gas supply chain: A case study

    International Nuclear Information System (INIS)

    Hamedi, Maryam; Zanjirani Farahani, Reza; Husseini, Mohammad Moattar; Esmaeilian, Gholam Reza

    2009-01-01

    In this paper, a real-world case study of a natural gas supply chain is investigated. By using concepts related to natural gas industry and the relations among the components of transmission and distribution network, a six-level supply chain has been introduced and presented schematically. The defined supply chain is a single-objective, multi-period, and single-product problem that is formulated as a mixed integer non-linear programming model, which can easily be linearized. The objective of this model is to minimize direct or indirect distribution costs. There are six groups of constraints including capacity, input and output balancing, demand satisfaction, network flow continuity, and relative constraints to the required binary variables. The solution algorithm of the problem is hierarchical; in each step, one section of the problem is solved using an exact method; the outputs of this section are passed to the next relative section as inputs. Finally, it is shown that the problem has been solved in a reasonable time and desirable results are attained. The use of proposed model and its solution approach have been studied in two gas trunk lines, to present the priority of its cost saving

  5. Distribution, vertical position and ecological implications of shallow gas in Bahía Blanca estuary (Argentina)

    Science.gov (United States)

    Bravo, M. E.; Aliotta, S.; Fiori, S.; Ginsberg, S.

    2018-03-01

    There has been a growing interest in the study of shallow gas due its importance in relation to the marine environment, climate change and human activities. In Bahía Blanca estuary, Argentina, shallow gas has a wide distribution. Acoustic turbidity and blanking are the main seismic evidence for the presence of shallow gas in the estuary. The former prevails in the inner sector of the estuary where gas is either near or in contact with the seabed. Gas deposits are generally associated with paleochannels corresponding to the Holocene paleodeltaic environment. Distribution studies of shallow gas in this estuary are necessary because its presence implies not only a geological risk for harbor activities but also because it may have noxious effects on the marine ecosystem, mainly on benthic communities. The comparison of benthic communities at a gas site (GS) with those at a control site (CS) indicated that gas could generate impoverishment in terms of individuals' abundance (GS: N = 357; CS: N = 724). Also, diversity indices showed great differences in the community structure at each site. This indicates that methane gas may act as a natural disturbance agent in estuarine ecosystems. The presence of gas in seabed sediments must therefore be taken into account when distribution studies are conducted of estuarine benthic communities.

  6. Determination of Anisotropic Ion Velocity Distribution Function in Intrinsic Gas Plasma. Theory.

    Science.gov (United States)

    Mustafaev, A.; Grabovskiy, A.; Murillo, O.; Soukhomlinov, V.

    2018-02-01

    The first seven coefficients of the expansion of the energy and angular distribution functions in Legendre polynomials for Hg+ ions in Hg vapor plasma with the parameter E/P ≈ 400 V/(cm Torr) are measured for the first time using a planar one-sided probe. The analytic solution to the Boltzmann kinetic equation for ions in the plasma of their parent gas is obtained in the conditions when the resonant charge exchange is the predominant process, and ions acquire on their mean free path a velocity much higher than the characteristic velocity of thermal motion of atoms. The presence of an ambipolar field of an arbitrary strength is taken into account. It is shown that the ion velocity distribution function is determined by two parameters and differs substantially from the Maxwellian distribution. Comparison of the results of calculation of the drift velocity of He+ ions in He, Ar+ in Ar, and Hg+ in Hg with the available experimental data shows their conformity. The results of the calculation of the ion distribution function correctly describe the experimental data obtained from its measurement. Analysis of the result shows that in spite of the presence of the strong field, the ion velocity distribution functions are isotropic for ion velocities lower than the average thermal velocity of atoms. With increasing ion velocity, the distribution becomes more and more extended in the direction of the electric field.

  7. Integrated resource planning for local gas distribution companies: A critical review of regulatory policy issues

    Energy Technology Data Exchange (ETDEWEB)

    Harunuzzaman, M.; Islam, M.

    1994-08-01

    According to the report, public utility commissions (PUCs) are increasingly adopting, or considering the adoption of integrated resource planning (IRP) for local gas distribution companies (LDCs). The Energy Policy Act of 1992 (EPAct) requires PUCs to consider IRP for gas LDCs. This study has two major objectives: (1) to help PUCs develop appropriate regulatory approaches with regard to IRP for gas LDCs; and (2) to help PUCs respond to the EPAct directive. The study finds that it is appropriate for PUCs to pursue energy efficiency within the traditional regulatory framework of minimizing private costs of energy production and delivery; and PUCs should play a limited role in addressing environmental externalities. The study also finds that in promoting energy efficiency, PUCs should pursue policies that are incentive-based, procompetitive, and sensitive to rate impacts. The study evaluates a number of traditional and nontraditional ratemaking mechanisms on the basis of cost minimization, energy efficiency, competitiveness, and other criteria. The mechanisms evaluated include direct recovery of DSM expenses, lost revenue adjustments for DSM options, revenue decoupling mechanisms, sharing of DSM cost savings, performance-based rate of return for DSM, provision of DSM as a separate service, deregulation of DSM service, price caps, and deregulation of the noncore gas market. The study concludes with general recommendations for regulatory approaches and ratemaking mechanisms that PUCs may wish to consider in advancing IRP objectives.

  8. Integrated resource planning for local gas distribution companies: A critical review of regulatory policy issues

    International Nuclear Information System (INIS)

    Harunuzzaman, M.; Islam, M.

    1994-08-01

    According to the report, public utility commissions (PUCs) are increasingly adopting, or considering the adoption of integrated resource planning (IRP) for local gas distribution companies (LDCs). The Energy Policy Act of 1992 (EPAct) requires PUCs to consider IRP for gas LDCs. This study has two major objectives: (1) to help PUCs develop appropriate regulatory approaches with regard to IRP for gas LDCs; and (2) to help PUCs respond to the EPAct directive. The study finds that it is appropriate for PUCs to pursue energy efficiency within the traditional regulatory framework of minimizing private costs of energy production and delivery; and PUCs should play a limited role in addressing environmental externalities. The study also finds that in promoting energy efficiency, PUCs should pursue policies that are incentive-based, procompetitive, and sensitive to rate impacts. The study evaluates a number of traditional and nontraditional ratemaking mechanisms on the basis of cost minimization, energy efficiency, competitiveness, and other criteria. The mechanisms evaluated include direct recovery of DSM expenses, lost revenue adjustments for DSM options, revenue decoupling mechanisms, sharing of DSM cost savings, performance-based rate of return for DSM, provision of DSM as a separate service, deregulation of DSM service, price caps, and deregulation of the noncore gas market. The study concludes with general recommendations for regulatory approaches and ratemaking mechanisms that PUCs may wish to consider in advancing IRP objectives

  9. 49 CFR 192.319 - Installation of pipe in a ditch.

    Science.gov (United States)

    2010-10-01

    ... NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS General Construction Requirements for..., except pipe in the Gulf of Mexico and its inlets under 15 feet (4.6 meters) of water, must be installed so that the top of the pipe is below the natural bottom unless the pipe is supported by stanchions...

  10. Development and training for the professional of the gas distribution industry in Brazil; Formation des professionnels de l'industrie de la distribution du gaz au Bresil

    Energy Technology Data Exchange (ETDEWEB)

    Hatsumi Nagato, D. [Workout Energy Business (Brazil)

    2000-07-01

    This work will present a Training and Development model for professionals of the gas distribution industry. Today's there are not schools developing gas related subjects. It's important to give to the future gas man, the knowledge needed to develop their activities. This can be achieved by focusing on criteria based on The Competency Concept and Learning Organization. To develop professional 'competency' we consider this tree of basic points: to know, to know how to do and wish to do ( willing ). We are going to present the 'minimum' 'competences' required for gas distribution companies and the methods used to qualify people for emergent gas industries, considering basically four professionals groups: workers, technicians, engineers and managers. (author)

  11. Approaching hydrate and free gas distribution at the SUGAR-Site location in the Danube Delta

    Science.gov (United States)

    Bialas, Joerg; Dannowski, Anke; Zander, Timo; Klaeschen, Dirk; Klaucke, Ingo

    2017-04-01

    Gas hydrates did receive a lot of attention over the last decades when investigating their potential to serve as a possible source for Methane production. Among other world-wide programs the German SUGAR project sets out to investigate the entire chain from exploitation to production in Europe. Therefore research in the scope of the SUGAR project sets out to investigate a site in European EEZ for the detailed studies of hydrate and gas distribution in a permeable sediment matrix. Among others one aim of the project is to provide in situ samples of natural methane hydrate for further investigations by MEBO drilling. The Danube paleo-delta with its ancient canyon and levee systems was chosen as a possible candidate for hydrate formation within the available drilling range of 200 m below seafloor. In order to decide on the best drilling location cruise MSM34 (Bialas et al., 2014) of the German RV MARIA S MERIAN set out to acquire geophysical, geological and geochemical datasets for assessment of the hydrate content within the Danube paleo-delta, Black Sea. The Black Sea is well known for a significant gas content in the sedimentary column. Reports on observations of bottom simulating reflectors (BSR) by Popescu et al. (2007) and others indicate that free gas and hydrate occurrence can be expected within the ancient passive channel levee systems. A variety of inverted reflection events within the gas hydrate stability zone (GHSZ) were observed within the drilling range of MEBO and chosen for further investigation. Here we report on combined seismic investigations of high-resolution 2D & 3D multichannel seismic (MCS) acquisition accompanied by four component Ocean-Bottom-Seismometer (OBS) observations. P- and converted S-wave arrivals within the OBS datasets were analysed to provide overall velocity depth models. Due to the limited length of profiles the majority of OBS events are caused by near vertical reflections. While P-wave events have a significant lateral

  12. Model documentation Natural Gas Transmission and Distribution Model of the National Energy Modeling System. Volume 1

    International Nuclear Information System (INIS)

    1996-01-01

    The Natural Gas Transmission and Distribution Model (NGTDM) of the National Energy Modeling System is developed and maintained by the Energy Information Administration (EIA), Office of Integrated Analysis and Forecasting. This report documents the archived version of the NGTDM that was used to produce the natural gas forecasts presented in the Annual Energy Outlook 1996, (DOE/EIA-0383(96)). The purpose of this report is to provide a reference document for model analysts, users, and the public that defines the objectives of the model, describes its basic approach, and provides detail on the methodology employed. Previously this report represented Volume I of a two-volume set. Volume II reported on model performance, detailing convergence criteria and properties, results of sensitivity testing, comparison of model outputs with the literature and/or other model results, and major unresolved issues

  13. Hydrocarbon halo distribution above oil and gas deposits with abnormally high stratal pressures

    Energy Technology Data Exchange (ETDEWEB)

    Bakhtin, V.V.

    1978-01-01

    An examination is made of the emergence of hydrocarbon halos over oil and gas deposits with abnormally high stratal pressure. Fields in Azerbaidzhan and Checheno-Ingushetiya are used to illustrate the effect of certain factors (particularly fractures, zones with heightened macro and microfissure formation) on halo morphology. A direct relationship was found between the intensity of microfissure formation (fissure permeability, volumetric density of microfissures) and the size of vertically directed halos. Dimensions are given for halos by cross-sectional profiles of the Khayan-Kort field, and information is given on the nature of bitumen saturation distribution within the halo. The identification of halos in the process of drilling will make it possible to improve the technology of cutting deep gas and oil exploratory wells in the regions of abnormally high stratal pressures are developing. 22 references, 4 figures, 1 table.

  14. Joint Costs in Electricity and Natural Gas Distribution Infrastructures: The Role of Urban Factors

    Directory of Open Access Journals (Sweden)

    Muzeyyen Anil Senyel

    2018-04-01

    Full Text Available This paper analyzes the joint cost structure of electricity and natural gas distribution investments. Assessing the joint costs is critical for urban development and public policy regarding competition at the local level. The paper accounts for the urban and geographic factors at the local level, while the previous literature primarily used company-level data with a few or no site-specific variables in joint cost analyses. An empirical analysis of the multi-utility capital costs suggests that the local urban and geographic conditions affect such costs, with economies of scope present in electricity and natural gas both in terms of total costs and underground investment costs. Hence, the joint service provision makes economic and environmental sense for urban policy makers.

  15. Model documentation Natural Gas Transmission and Distribution Model of the National Energy Modeling System. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-02-26

    The Natural Gas Transmission and Distribution Model (NGTDM) of the National Energy Modeling System is developed and maintained by the Energy Information Administration (EIA), Office of Integrated Analysis and Forecasting. This report documents the archived version of the NGTDM that was used to produce the natural gas forecasts presented in the Annual Energy Outlook 1996, (DOE/EIA-0383(96)). The purpose of this report is to provide a reference document for model analysts, users, and the public that defines the objectives of the model, describes its basic approach, and provides detail on the methodology employed. Previously this report represented Volume I of a two-volume set. Volume II reported on model performance, detailing convergence criteria and properties, results of sensitivity testing, comparison of model outputs with the literature and/or other model results, and major unresolved issues.

  16. Burnable gas concentration control device

    International Nuclear Information System (INIS)

    Goto, Hiroshi; Sanada, Takahiro; Kuboniwa, Takao.

    1980-01-01

    Purpose: To provide connecting ports by doubling nitrogen gas injection pipes thereby to secure lengthiness of the device only by providing one nitrogen gas generator. Constitution: Nitrogen gas injection pipes are provided in two lines separately, and attachable and detachable connecting ports for feeding nitrogen gas connectable to a movable type nitrogen gas supply installation for the purpose of backing up the nitrogen gas generator. (Yoshihara, H.)

  17. A thermal study of pipes with outer transverse fins

    Directory of Open Access Journals (Sweden)

    S. Gil

    2016-10-01

    Full Text Available This paper provides results of thermal investigations on pipes with outer transverse fins produced by placing a strip, being a form of helical spring which functions as a radiator, on the basis pipe. The investigations were carried out at the facility that enables measurements with respect to both natural and forced convection. Performance of the investigated pipes was assessed in relation to a non-finned pipe and a pipe welded with the use of Metal Active Gas (MAG technology. The experiments have shown that the finned pipe welding technology does not markedly affect their thermal efficiency, which has been confirmed by performed model calculations, while the welding technology has a crucial impact on their operating performance.

  18. Design of a cavity heat pipe receiver experiment

    Science.gov (United States)

    Schneider, Michael G.; Brege, Mark H.; Greenlee, William J.

    1992-01-01

    A cavity heat pipe experiment has been designed to test the critical issues involved with incorporating thermal energy storage canisters into a heat pipe. The experiment is a replication of the operation of a heat receiver for a Brayton solar dynamic power cycle. The heat receiver is composed of a cylindrical receptor surface and an annular heat pipe with thermal energy storage canisters and gaseous working fluid heat exchanger tubes surrounding it. Hardware for the cavity heat pipe experiment will consist of a sector of the heat pipe, complete with gas tube and thermal energy storage canisters. Thermal cycling tests will be performed on the heat pipe sector to simulate the normal energy charge/discharge cycle of the receiver in a spacecraft application.

  19. Analysis and Optimisation of Carcass Production for Flexible Pipes

    DEFF Research Database (Denmark)

    Nielsen, Peter Søe

    Un-bonded flexible pipes are used in the offshore oil and gas industry worldwide transporting hydrocarbons from seafloor to floating production vessels topside. Flexible pipes are advantageous over rigid pipelines in dynamic applications and during installation as they are delivered in full length...... on reels. Flexible pipes are constructed in a layer structure in which each layer adds specific properties to the pipe such as; collapse strength, fluid integrity, bursting strength, tensile strength etc. The inner-most layer of a flexible pipe is the carcass; a flexible interlocking stainless steel...... structure that provides mechanical and collapse strength for the flexible pipe. The manufacturing process of carcass is a combination of roll forming stainless steel strips and helical winding the profiles around a mandrel interlocking the profiles with themselves. The focus of the present project...

  20. Introduction to Heat Pipes

    Science.gov (United States)

    Ku, Jentung

    2015-01-01

    This is the presentation file for the short course Introduction to Heat Pipes, to be conducted at the 2015 Thermal Fluids and Analysis Workshop, August 3-7, 2015, Silver Spring, Maryland. NCTS 21070-15. Course Description: This course will present operating principles of the heat pipe with emphases on the underlying physical processes and requirements of pressure and energy balance. Performance characterizations and design considerations of the heat pipe will be highlighted. Guidelines for thermal engineers in the selection of heat pipes as part of the spacecraft thermal control system, testing methodology, and analytical modeling will also be discussed.

  1. Piping engineering and operation

    International Nuclear Information System (INIS)

    1993-01-01

    The conference 'Piping Engineering and Operation' was organized by the Institution of Mechanical Engineers in November/December 1993 to follow on from similar successful events of 1985 and 1989, which were attended by representatives from all sectors of the piping industry. Development of engineering and operation of piping systems in all aspects, including non-metallic materials, are highlighted. The range of issues covered represents a balance between current practices and implementation of future international standards. Twenty papers are printed. Two, which are concerned with pressurized pipes or steam lines in the nuclear industry, are indexed separately. (Author)

  2. Ion angular distribution in plasma of vacuum arc ion source with composite cathode and elevated gas pressure.

    Science.gov (United States)

    Nikolaev, A G; Savkin, K P; Yushkov, G Yu; Oks, E M

    2014-02-01

    The Metal Vapor Vacuum Arc (MEVVA) ion sources are capable of generating ion beams of almost all metals of the periodic table. For this kind of ion source, a combination of gas feeding with magnetic field allows the simultaneous generation of both metal and gaseous ions. That makes the MEVVA ion source an excellent instrument for science and application. This work presents results of investigation for ion angular distributions in vacuum arc plasma of Mevva-V.Ru ion source for composite cathodes and for elevated gas pressure. It was shown that for all the cathode materials, singly charged ions have wider angular distribution than multiply charged ions. Increasing the working gas pressure leads to a significant change in the angular distribution of gaseous ions, while with the distribution of metal ions gas remains practically unchanged. The reasons for such different influences are discussed.

  3. 46 CFR 76.15-15 - Piping.

    Science.gov (United States)

    2010-10-01

    ... or other openings within such spaces. (j) Installation test requirements: (1) Upon completion of the piping installation, and before the cylinders are connected, a pressure test shall be applied as set forth in this paragraph. Only carbon dioxide or other inert gas shall be used for this test. (2) The...

  4. 49 CFR 192.197 - Control of the pressure of gas delivered from high-pressure distribution systems.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Control of the pressure of gas delivered from high-pressure distribution systems. 192.197 Section 192.197 Transportation Other Regulations Relating to... (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY...

  5. 49 CFR 192.1005 - What must a gas distribution operator (other than a master meter or small LPG operator) do to...

    Science.gov (United States)

    2010-10-01

    ... BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Gas Distribution Pipeline Integrity Management (IM) § 192.1005 What must a gas distribution operator (other than a master meter or small LPG operator) do to... 49 Transportation 3 2010-10-01 2010-10-01 false What must a gas distribution operator (other than...

  6. Pipe rupture and steam/water hammer design loads for dynamic analysis of piping systems

    International Nuclear Information System (INIS)

    Strong, B.R. Jr.; Baschiere, R.J.

    1978-01-01

    The design of restraints and protection devices for nuclear Class I and Class II piping systems must consider severe pipe rupture and steam/water hammer loadings. Limited stress margins require that an accurate prediction of these loads be obtained with a minimum of conservatism in the loads. Methods are available currently for such fluid transient load development, but each method is severely restricted as to the complexity and/or the range of fluid state excursions which can be simulated. This paper presents a general technique for generation of pipe rupture and steam/water hammer design loads for dynamic analysis of nuclear piping systems which does not have the limitations of existing methods. Blowdown thrust loadings and unbalanced piping acceleration loads for restraint design of all nuclear piping systems may be found using this method. The technique allows the effects of two-phase distributed friction, liquid flashing and condensation, and the surrounding thermal and mechanical equipment to be modeled. A new form of the fluid momentum equation is presented which incorporates computer generated fluid acceleration histories by inclusion of a geometry integral termed the 'force equivalent area' (FEA). The FEA values permit the coupling of versatile thermal-hydraulic programs to piping dynamics programs. Typical applications of the method to pipe rupture problems are presented and the resultant load histories compared with existing techniques. (Auth.)

  7. Field investigation on structural performance of the buried UPVC pipes with and without geogrid reinforcement

    Science.gov (United States)

    Teja, Akkineni Surya; Rajkumar, R.; Gokula Krishnan, B.; Aravindh, R.

    2018-02-01

    Buried pipes are used mainly for water supply and drainage besides many other applications such as oil, liquefied natural gas, coal slurries and mine tailings. The pipes used may be rigid (reinforced concrete, vitrified clay and ductile iron) or flexible (Steel, UPVC, aluminium, Fiber glass and High-density polyethylene) although the distinction between them is blurring. Flexible pipe design is governed by deflection or buckling. UPVC pipes are preferred due to light weight, long term chemical stability and cost efficiency. This project aims to study the load deformation behaviour of the buried pipe and stress variation across the cross section of the pipe under static loading along with the influence of depth of embedment, density of backfill on the deformation and stresses in pipe and the deformation behaviour of buried pipe when soil is reinforced with geogrid reinforcement and evaluate the structural performance of the pipe.

  8. Conjugated heat transfer and temperature distributions in a gas turbine combustion liner under base-load operation

    International Nuclear Information System (INIS)

    Kim, Kyung Min; Yun, Nam Geon; Jeon, Yun Heung; Lee, Dong Hyun; Cho, Yung Hee

    2010-01-01

    Prediction of temperature distributions on hot components is important in development of a gas turbine combustion liner. The present study investigated conjugated heat transfer to obtain temperature distributions in a combustion liner with six combustion nozzles. 3D numerical simulations using FVM commercial codes, Fluent and CFX were performed to calculate combustion and heat transfer distributions. The temperature distributions in the combustor liner were calculated by conjugation of conduction and convection (heat transfer coefficients) obtained by combustion and cooling flow analysis. The wall temperature was the highest on the attachment points of the combustion gas from combustion nozzles, but the temperature gradient was high at the after shell section with low wall temperature

  9. 77 FR 13079 - Certain Large Diameter Carbon and Alloy Seamless Standard, Line, and Pressure Pipe (Over 41/2

    Science.gov (United States)

    2012-03-05

    ... natural gas or other fluids in pipe lines. Seamless line pipes are produced to the API 5L specification... comments on a computer diskette. Case and rebuttal briefs must be served on interested parties in...

  10. Hot Leg Piping Materials Issues

    International Nuclear Information System (INIS)

    V. Munne

    2006-01-01

    With Naval Reactors (NR) approval of the Naval Reactors Prime Contractor Team (NRPCT) recommendation to develop a gas cooled reactor directly coupled to a Brayton power conversion system as the space nuclear power plant (SNPP) for Project Prometheus (References a and b) the reactor outlet piping was recognized to require a design that utilizes internal insulation (Reference c). The initial pipe design suggested ceramic fiber blanket as the insulation material based on requirements associated with service temperature capability within the expected range, very low thermal conductivity, and low density. Nevertheless, it was not considered to be well suited for internal insulation use because its very high surface area and proclivity for holding adsorbed gases, especially water, would make outgassing a source of contaminant gases in the He-Xe working fluid. Additionally, ceramic fiber blanket insulating materials become very friable after relatively short service periods at working temperatures and small pieces of fiber could be dislodged and contaminate the system. Consequently, alternative insulation materials were sought that would have comparable thermal properties and density but superior structural integrity and greatly reduced outgassing. This letter provides technical information regarding insulation and materials issues for the Hot Leg Piping preconceptual design developed for the Project Prometheus space nuclear power plant (SNPP)

  11. Infrared imaging spectroscopy of the Galactic center - Distribution and motions of the ionized gas

    Science.gov (United States)

    Herbst, T. M.; Beckwith, S. V. W.; Forrest, W. J.; Pipher, J. L.

    1993-01-01

    High spatial spectral resolution IR images of the Galactic center in the Br-gamma recombination line of hydrogen were taken. A coherent filament of gas extending from north of IRS 1, curving around IRS 16/Sgr A complex, and continuing to the southwest, is seen. Nine stellar sources have associated Br-gamma emission. The total Br-gamma line flux in the filament is approximately 3 x 10 exp -15 W/sq m. The distribution and kinematics of the northern arm suggest orbital motion; the observations are accordingly fit with elliptical orbits in the field of a central point of mass.

  12. Heat Pipe with Axial Wick

    Science.gov (United States)

    Ambrose, Jay H. (Inventor); Holmes, Rolland (Inventor)

    2016-01-01

    A heat pipe has an evaporator portion, a condenser portion, and at least one flexible portion that is sealingly coupled between the evaporator portion and the condenser portion. The flexible portion has a flexible tube and a flexible separator plate held in place within the flexible tube so as to divide the flexible tube into a gas-phase passage and a liquid-phase artery. The separator plate and flexible tube are configured such that the flexible portion is flexible in a plane that is perpendicular to the separator plate.

  13. Flow behaviour and local concentration of coarse particles-water mixture in inclined pipes

    Directory of Open Access Journals (Sweden)

    Vlasak Pavel

    2017-06-01

    Full Text Available Narrow particle size distribution basalt pebbles of mean particle size 11.5 mm conveyed by water in the pipe sections of different inclination were investigated on an experimental pipe loop, consisting of smooth stainless steel pipes of inner diameter D = 100 mm. Mixture flow-behaviour and particles motion along the pipe invert were studied in a pipe viewing section, the concentration distribution in pipe cross-section was studied with the application of a gamma-ray densitometer. The study refers to the effect of mixture velocity, overall concentration, and angle of pipe inclination on chord-averaged concentration profiles and local concentration maps, and flow behaviour of the coarse particle-water mixtures. The study revealed that the coarse particle-water mixtures in the inclined pipe sections were significantly stratified, the solid particles moved principally close to the pipe invert, and for higher and moderate flow velocities particle saltation becomes the dominant mode of particle conveying.

  14. Distribution of Zeros and the Equation of State. III : Cluster Series, the Ideal Fermi-Dirac Gas and Other Problems

    OpenAIRE

    Kazuyosi, IKEDA; Department of Applied Physics, Osaka University

    1982-01-01

    The radius of convergence of the cluster series (expressing the equation of state) is discussed in connection with the distribution of zeros of the grand partition function on the complex z (= activity) plane, by giving various examples of circular distribution. Anomalous phase transitions and phase transitions of third order are considered by showing some examples of circular distribution of zeros. For the ideal Fermi-Dirac gas, the distribution function of zeros, lying on the part of the ne...

  15. Distribution of natural gas: introduction of the interruptible segment in Sao Paulo, Brazil; Distribuicao de gas natural canalizado: introducao do segmento interruptivel em Sao Paulo

    Energy Technology Data Exchange (ETDEWEB)

    Paula, Claudio Paiva de [Agencia Reguladora de Saneamento e Energia do Estado de Sao Paulo (ARSESP), SP (Brazil)

    2008-07-01

    The principal objective of this paper is the better knowledge and evaluation of the natural gas distribution network interruptible branch. This new service can be appropriate for thermal power generation on flexible dispatch mode, as 'take or pay' contracts surplus jobs. The paper indicates no regulatory restraints in an interruptible network implantation and one can guess that the inexistence of contracts for this service resembles only lack of conjunctural opportunities for this job applications. These difficulties appear both in the supply and distribution branches of the gas business, which prefer flat contracts. The final conclusion is interruptible contracts can be an improvement on the distribution business and certainly can accommodate a suitable demand and supply volumes in the long-term gas market balance. (author)

  16. Distribution Integrity Management Plant (DIMP)

    Energy Technology Data Exchange (ETDEWEB)

    Gonzales, Jerome F. [Los Alamos National Laboratory

    2012-05-07

    This document is the distribution integrity management plan (Plan) for the Los Alamos National Laboratory (LANL) Natural Gas Distribution System. This Plan meets the requirements of 49 CFR Part 192, Subpart P Distribution Integrity Management Programs (DIMP) for the LANL Natural Gas Distribution System. This Plan was developed by reviewing records and interviewing LANL personnel. The records consist of the design, construction, operation and maintenance for the LANL Natural Gas Distribution System. The records system for the LANL Natural Gas Distribution System is limited, so the majority of information is based on the judgment of LANL employees; the maintenance crew, the Corrosion Specialist and the Utilities and Infrastructure (UI) Civil Team Leader. The records used in this report are: Pipeline and Hazardous Materials Safety Administration (PHMSA) 7100.1-1, Report of Main and Service Line Inspection, Natural Gas Leak Survey, Gas Leak Response Report, Gas Leak and Repair Report, and Pipe-to-Soil Recordings. The specific elements of knowledge of the infrastructure used to evaluate each threat and prioritize risks are listed in Sections 6 and 7, Threat Evaluation and Risk Prioritization respectively. This Plan addresses additional information needed and a method for gaining that data over time through normal activities. The processes used for the initial assessment of Threat Evaluation and Risk Prioritization are the methods found in the Simple, Handy Risk-based Integrity Management Plan (SHRIMP{trademark}) software package developed by the American Pipeline and Gas Agency (APGA) Security and Integrity Foundation (SIF). SHRIMP{trademark} uses an index model developed by the consultants and advisors of the SIF. Threat assessment is performed using questions developed by the Gas Piping Technology Company (GPTC) as modified and added to by the SHRIMP{trademark} advisors. This Plan is required to be reviewed every 5 years to be continually refined and improved. Records

  17. Development of Next Generation Multiphase Pipe Flow Prediction Tools

    Energy Technology Data Exchange (ETDEWEB)

    Tulsa Fluid Flow

    2008-08-31

    The developments of fields in deep waters (5000 ft and more) is a common occurrence. It is inevitable that production systems will operate under multiphase flow conditions (simultaneous flow of gas-oil-and water possibly along with sand, hydrates, and waxes). Multiphase flow prediction tools are essential for every phase of the hydrocarbon recovery from design to operation. The recovery from deep-waters poses special challenges and requires accurate multiphase flow predictive tools for several applications including the design and diagnostics of the production systems, separation of phases in horizontal wells, and multiphase separation (topside, seabed or bottom-hole). It is very crucial to any multiphase separation technique that is employed either at topside, seabed or bottom-hole to know inlet conditions such as the flow rates, flow patterns, and volume fractions of gas, oil and water coming into the separation devices. The overall objective was to develop a unified model for gas-oil-water three-phase flow in wells, flow lines, and pipelines to predict the flow characteristics such as flow patterns, phase distributions, and pressure gradient encountered during petroleum production at different flow conditions (pipe diameter and inclination, fluid properties and flow rates). The project was conducted in two periods. In Period 1 (four years), gas-oil-water flow in pipes were investigated to understand the fundamental physical mechanisms describing the interaction between the gas-oil-water phases under flowing conditions, and a unified model was developed utilizing a novel modeling approach. A gas-oil-water pipe flow database including field and laboratory data was formed in Period 2 (one year). The database was utilized in model performance demonstration. Period 1 primarily consisted of the development of a unified model and software to predict the gas-oil-water flow, and experimental studies of the gas-oil-water project, including flow behavior description and

  18. Generic features of the wealth distribution in ideal-gas-like markets.

    Science.gov (United States)

    Mohanty, P K

    2006-07-01

    We provide an exact solution to the ideal-gas-like models studied in econophysics to understand the microscopic origin of Pareto law. In these classes of models the key ingredient necessary for having a self-organized scale-free steady-state distribution is the trading or collision rule where agents or particles save a definite fraction of their wealth or energy and invest the rest for trading. Using a Gibbs ensemble approach we could obtain the exact distribution of wealth in this model. Moreover we show that in this model (a) good savers are always rich and (b) every agent poor or rich invests the same amount for trading. Nonlinear trading rules could alter the generic scenario observed here.

  19. A Robust Distributed Multipoint Fiber Optic Gas Sensor System Based on AGC Amplifier Structure.

    Science.gov (United States)

    Zhu, Cunguang; Wang, Rende; Tao, Xuechen; Wang, Guangwei; Wang, Pengpeng

    2016-07-28

    A harsh environment-oriented distributed multipoint fiber optic gas sensor system realized by automatic gain control (AGC) technology is proposed. To improve the photoelectric signal reliability, the electronic variable gain can be modified in real time by an AGC closed-loop feedback structure to compensate for optical transmission loss which is caused by the fiber bend loss or other reasons. The deviation of the system based on AGC structure is below 4.02% when photoelectric signal decays due to fiber bending loss for bending radius of 5 mm, which is 20 times lower than the ordinary differential system. In addition, the AGC circuit with the same electric parameters can keep the baseline intensity of signals in different channels of the distributed multipoint sensor system at the same level. This avoids repetitive calibrations and streamlines the installation process.

  20. Tomography for two-dimensional gas temperature distribution based on TDLAS

    Science.gov (United States)

    Luo, Can; Wang, Yunchu; Xing, Fei

    2018-03-01

    Based on tunable diode laser absorption spectroscopy (TDLAS), the tomography is used to reconstruct the combustion gas temperature distribution. The effects of number of rays, number of grids, and spacing of rays on the temperature reconstruction results for parallel ray are researched. The reconstruction quality is proportional to the ray number. The quality tends to be smoother when the ray number exceeds a certain value. The best quality is achieved when η is between 0.5 and 1. A virtual ray method combined with the reconstruction algorithms is tested. It is found that virtual ray method is effective to improve the accuracy of reconstruction results, compared with the original method. The linear interpolation method and cubic spline interpolation method, are used to improve the calculation accuracy of virtual ray absorption value. According to the calculation results, cubic spline interpolation is better. Moreover, the temperature distribution of a TBCC combustion chamber is used to validate those conclusions.

  1. Systematic studies of the gas humidification effects on spatial PEMFC performance distributions

    International Nuclear Information System (INIS)

    Reshetenko, Tatyana V.; Bender, Guido; Bethune, Keith; Rocheleau, Richard

    2012-01-01

    Highlights: ► We investigated impacts of gases humidification on a local PEMFC performance. ► The spatial performance and EIS were studied by a segmented cell system. ► The data were analyzed in the terms of voltage losses. ► A reduction in anode/cathode gases humidification decreased a PEMFC performance. ► A decrease of humidification led to non-uniform performances and voltage losses distributions. - Abstract: The overall current density that is measured in a proton exchange membrane fuel cell (PEMFC) represents the average of the local reaction rates. The overall and local PEMFC performances are determined by several primary loss mechanisms, namely activation, ohmic, and mass transfer. Spatial performance and loss variabilities are significant and depend on the cell design and operating conditions. A segmented cell system was used to quantify different loss distributions along the gas channel to understand the effects of gas humidification. A reduction in the reactant stream humidification decreased cell performance and resulted in non-uniform distributions of overpotentials and performance along the flow field. Activation and ohmic overpotentials increased with a relative humidity decrease due to insufficient membrane and catalyst layer hydration. The relative humidity of the cathode had a strong impact on the mass transfer overpotential due to a lower oxygen permeability through the dry Nafion film covering the catalyst surface. The mass transfer loss distribution was non-uniform, and the mass transfer overpotential increased for the outlet segments due to the oxygen consumption at the inlet segments, which reduced the oxygen concentration downstream, and a progressive water accumulation from upstream segments. Electrochemical impedance spectroscopy (EIS) and an equivalent electric circuit (EEC) facilitated the analysis and interpretation of the segmented cell data.

  2. Characterization of gas hydrate distribution using conventional 3D seismic data in the Pearl River Mouth Basin, South China Sea

    Science.gov (United States)

    Wang, Xiujuan; Qiang, Jin; Collett, Timothy S.; Shi, Hesheng; Yang, Shengxiong; Yan, Chengzhi; Li, Yuanping; Wang, Zhenzhen; Chen, Duanxin

    2016-01-01

    A new 3D seismic reflection data volume acquired in 2012 has allowed for the detailed mapping and characterization of gas hydrate distribution in the Pearl River Mouth Basin in the South China Sea. Previous studies of core and logging data showed that gas hydrate occurrence at high concentrations is controlled by the presence of relatively coarse-grained sediment and the upward migration of thermogenic gas from the deeper sediment section into the overlying gas hydrate stability zone (BGHSZ); however, the spatial distribution of the gas hydrate remains poorly defined. We used a constrained sparse spike inversion technique to generate acoustic-impedance images of the hydrate-bearing sedimentary section from the newly acquired 3D seismic data volume. High-amplitude reflections just above the bottom-simulating reflectors (BSRs) were interpreted to be associated with the accumulation of gas hydrate with elevated saturations. Enhanced seismic reflections below the BSRs were interpreted to indicate the presence of free gas. The base of the BGHSZ was established using the occurrence of BSRs. In areas absent of well-developed BSRs, the BGHSZ was calculated from a model using the inverted P-wave velocity and subsurface temperature data. Seismic attributes were also extracted along the BGHSZ that indicate variations reservoir properties and inferred hydrocarbon accumulations at each site. Gas hydrate saturations estimated from the inversion of acoustic impedance of conventional 3D seismic data, along with well-log-derived rock-physics models were also used to estimate gas hydrate saturations. Our analysis determined that the gas hydrate petroleum system varies significantly across the Pearl River Mouth Basin and that variability in sedimentary properties as a product of depositional processes and the upward migration of gas from deeper thermogenic sources control the distribution of gas hydrates in this basin.

  3. Planar Indium Tin Oxide Heater for Improved Thermal Distribution for Metal Oxide Micromachined Gas Sensors.

    Science.gov (United States)

    Çakır, M Cihan; Çalışkan, Deniz; Bütün, Bayram; Özbay, Ekmel

    2016-09-29

    Metal oxide gas sensors with integrated micro-hotplate structures are widely used in the industry and they are still being investigated and developed. Metal oxide gas sensors have the advantage of being sensitive to a wide range of organic and inorganic volatile compounds, although they lack selectivity. To introduce selectivity, the operating temperature of a single sensor is swept, and the measurements are fed to a discriminating algorithm. The efficiency of those data processing methods strongly depends on temperature uniformity across the active area of the sensor. To achieve this, hot plate structures with complex resistor geometries have been designed and additional heat-spreading structures have been introduced. In this work we designed and fabricated a metal oxide gas sensor integrated with a simple square planar indium tin oxide (ITO) heating element, by using conventional micromachining and thin-film deposition techniques. Power consumption-dependent surface temperature measurements were performed. A 420 °C working temperature was achieved at 120 mW power consumption. Temperature distribution uniformity was measured and a 17 °C difference between the hottest and the coldest points of the sensor at an operating temperature of 290 °C was achieved. Transient heat-up and cool-down cycle durations are measured as 40 ms and 20 ms, respectively.

  4. Planar Indium Tin Oxide Heater for Improved Thermal Distribution for Metal Oxide Micromachined Gas Sensors

    Directory of Open Access Journals (Sweden)

    M. Cihan Çakır

    2016-09-01

    Full Text Available Metal oxide gas sensors with integrated micro-hotplate structures are widely used in the industry and they are still being investigated and developed. Metal oxide gas sensors have the advantage of being sensitive to a wide range of organic and inorganic volatile compounds, although they lack selectivity. To introduce selectivity, the operating temperature of a single sensor is swept, and the measurements are fed to a discriminating algorithm. The efficiency of those data processing methods strongly depends on temperature uniformity across the active area of the sensor. To achieve this, hot plate structures with complex resistor geometries have been designed and additional heat-spreading structures have been introduced. In this work we designed and fabricated a metal oxide gas sensor integrated with a simple square planar indium tin oxide (ITO heating element, by using conventional micromachining and thin-film deposition techniques. Power consumption–dependent surface temperature measurements were performed. A 420 °C working temperature was achieved at 120 mW power consumption. Temperature distribution uniformity was measured and a 17 °C difference between the hottest and the coldest points of the sensor at an operating temperature of 290 °C was achieved. Transient heat-up and cool-down cycle durations are measured as 40 ms and 20 ms, respectively.

  5. Coarse particles-water mixtures flow in pipes

    Directory of Open Access Journals (Sweden)

    П. Власак

    2017-06-01

    Full Text Available The present paper is focused on evaluation of the effect of average mixture velocity and overall concentration on the pressure drop versus the slurry average velocity relationship, on slurry flow behaviour and local concentration distribution. The experimental investigation was carried out on the pipe loop of inner diameter D =100 mm, which consists of smooth stainless steel pipes and horizontal, inclinable and vertical pipe sections. The frictional pressure drop in the horizontal pipe section were significantly higher than that in the vertical pipe due to the fact, that for stratified flow the contact load produced significant energy losses. The frictional pressure drop of coarse particles mixtures in vertical pipe increased with the increasing mixture concentration and velocity, what confirmed effect of inner friction, inter-particles collision, and the drag due to particle-liquid slip. It was found that for stratified coarse particles-water mixture the frictional pressure drop was not significantly influenced by the pipe inclination, especially for low concentration values. The effect of pipe inclination decreased with increasing mixture velocity in ascending pipe section; the maximum value was reached for inclination between 20 and 40 degrees. Inclination of pressure drop maximum increased with decreasing mixture velocity. In descending pipe section the frictional pressure drop gradually decreased with increasing pipe inclination. The effect of inclination on frictional pressure drops could be practically neglected, especially for low mixture concentration and higher flow velocities. The study revealed that the coarse particle-water mixtures in the horizontal and inclined pipe sections were significantly stratified. The particles moved principally in a layer close to the pipe invert. However, for higher and moderate flow velocities the particles moved also in the central part of the pipe cross-section, and particle saltation [1] was found to

  6. Piping research program plan

    International Nuclear Information System (INIS)

    1988-09-01

    This document presents the piping research program plan for the Structural and Seismic Engineering Branch and the Materials Engineering Branch of the Division of Engineering, Office of Nuclear Regulatory Research. The plan describes the research to be performed in the areas of piping design criteria, environmentally assisted cracking, pipe fracture, and leak detection and leak rate estimation. The piping research program addresses the regulatory issues regarding piping design and piping integrity facing the NRC today and in the foreseeable future. The plan discusses the regulatory issues and needs for the research, the objectives, key aspects, and schedule for each research project, or group of projects focussing of a specific topic, and, finally, the integration of the research areas into the regulatory process is described. The plan presents a snap-shot of the piping research program as it exists today. However, the program plan will change as the regulatory issues and needs change. Consequently, this document will be revised on a bi-annual basis to reflect the changes in the piping research program. (author)

  7. Anisotropy of the neutral gas distribution of Comet Halley deduced from NGE/Vega 1 measurements. [Neutral Gas Experiment (NGE)

    Science.gov (United States)

    Hsieh, K. C.; Eip, WING-H. AFKEPPLER, E. agrichter, a. k; Eip, WING-H. AFKEPPLER, E. agrichter, a. k

    1986-01-01

    The neutral gas density profile of comet Halley measured by the Neutral Gas Experiment on Vega 1 showed an asymmetry between the inbound and the outbound legs during the fly-by on 6 March 1986. The implications of this asymmetry are discussed, and it is shown how the asymmetry detected by NGE on Vega 1 can be traced back to regions on or near the nucleus to obtain their relative gas production activities at specific times of emission.

  8. 75 FR 13644 - TORP Terminal LP, Bienville Offshore Energy Terminal Liquefied Natural Gas Deepwater Port License...

    Science.gov (United States)

    2010-03-22

    ... unit would regasify the LNG and deliver the gas via flexible gas pipes to the floating regasification... unit, two mooring lines that connect the HiLoad to the FRU, two high pressure (HP) flexible gas pipes...

  9. Supergalactic studies. II. Supergalactic distribution of the nearest intergalactic gas clouds

    International Nuclear Information System (INIS)

    de Vaucouleurs, G.; Corwin, H.G. Jr.

    1975-01-01

    The report by Mathewson, Cleary, and Murray that the nearby ''high velocity'' H i clouds, and in particular the Magellanic Stream, are strongly concentrated toward the supergalactic plane is confirmed. The observed concentration within +-30degree from the supergalactic equator of 21 out of 25 clouds in the north galactic hemisphere and 27 out of 31 clouds in the south galactic hemisphere could occur by chance in less than 7 and 3 percent of random samples from a population having a statistically isotropic Poisson distribution. Since the two galactic hemispheres are substantially independent samples, the combined probability of the chance hypothesis is P -3 . It is found that actually the high-velocity clouds are not so much concentrated toward the supergalactic equator (SGE) as toward the equator of the ''Local Cloud'' of galaxies inclined 14degree to the main supergalactic plane. Both galaxies and H i clouds define the same small circle of maximum concentration and exhibit the same standard deviation (15degree) from it, demonstrating closely related space distributions. It is concluded that, with the possible exception of a few of the largest and probably nearest cloud complexes (MS, AC, C), most of the high-velocity clouds are truly intergalactic and associated with the Local Group and nearer groups of galaxies. Half the population in a total sample of 115 nearby galaxies and intergalactic gas coulds is within 11degree from the Local equator, indicating a half-thickness of approx.0.75 Mpc for the Local Cloud. Intergalactic gas clouds have already been identified near 10 of the nearest galaxies (including our Galaxy and the Magellanic Clouds), most within approx.3 Mpc. The estimated space density of intergalactic gas clouds is Napprox. =20--25 Mpc -3 , in approximate agreement with the densities required by the collision theory of ring galaxies

  10. Air quality impacts of projections of natural gas-fired distributed generation

    Science.gov (United States)

    Horne, Jeremy R.; Carreras-Sospedra, Marc; Dabdub, Donald; Lemar, Paul; Nopmongcol, Uarporn; Shah, Tejas; Yarwood, Greg; Young, David; Shaw, Stephanie L.; Knipping, Eladio M.

    2017-11-01

    This study assesses the potential impacts on emissions and air quality from the increased adoption of natural gas-fired distributed generation of electricity (DG), including displacement of power from central power generation, in the contiguous United States. The study includes four major tasks: (1) modeling of distributed generation market penetration; (2) modeling of central power generation systems; (3) modeling of spatially and temporally resolved emissions; and (4) photochemical grid modeling to evaluate the potential air quality impacts of increased DG penetration, which includes both power-only DG and combined heat and power (CHP) units, for 2030. Low and high DG penetration scenarios estimate the largest penetration of future DG units in three regions - New England, New York, and California. Projections of DG penetration in the contiguous United States estimate 6.3 GW and 24 GW of market adoption in 2030 for the low DG penetration and high DG penetration scenarios, respectively. High DG penetration (all of which is natural gas-fired) serves to offset 8 GW of new natural gas combined cycle (NGCC) units, and 19 GW of solar photovoltaic (PV) installations by 2030. In all scenarios, air quality in the central United States and the northwest remains unaffected as there is little to no DG penetration in those states. California and several states in the northeast are the most impacted by emissions from DG units. Peak increases in maximum daily 8-h average ozone concentrations exceed 5 ppb, which may impede attainment of ambient air quality standards. Overall, air quality impacts from DG vary greatly based on meteorological conditions, proximity to emissions sources, the number and type of DG installations, and the emissions factors used for DG units.

  11. Model documentation: Natural Gas Transmission and Distribution Model of the National Energy Modeling System; Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-02-24

    The Natural Gas Transmission and Distribution Model (NGTDM) is a component of the National Energy Modeling System (NEMS) used to represent the domestic natural gas transmission and distribution system. NEMS is the third in a series of computer-based, midterm energy modeling systems used since 1974 by the Energy Information Administration (EIA) and its predecessor, the Federal Energy Administration, to analyze domestic energy-economy markets and develop projections. This report documents the archived version of NGTDM that was used to produce the natural gas forecasts used in support of the Annual Energy Outlook 1994, DOE/EIA-0383(94). The purpose of this report is to provide a reference document for model analysts, users, and the public that defines the objectives of the model, describes its basic design, provides detail on the methodology employed, and describes the model inputs, outputs, and key assumptions. It is intended to fulfill the legal obligation of the EIA to provide adequate documentation in support of its models (Public Law 94-385, Section 57.b.2). This report represents Volume 1 of a two-volume set. (Volume 2 will report on model performance, detailing convergence criteria and properties, results of sensitivity testing, comparison of model outputs with the literature and/or other model results, and major unresolved issues.) Subsequent chapters of this report provide: (1) an overview of the NGTDM (Chapter 2); (2) a description of the interface between the National Energy Modeling System (NEMS) and the NGTDM (Chapter 3); (3) an overview of the solution methodology of the NGTDM (Chapter 4); (4) the solution methodology for the Annual Flow Module (Chapter 5); (5) the solution methodology for the Distributor Tariff Module (Chapter 6); (6) the solution methodology for the Capacity Expansion Module (Chapter 7); (7) the solution methodology for the Pipeline Tariff Module (Chapter 8); and (8) a description of model assumptions, inputs, and outputs (Chapter 9).

  12. Oscillating heat pipes

    CERN Document Server

    Ma, Hongbin

    2015-01-01

    This book presents the fundamental fluid flow and heat transfer principles occurring in oscillating heat pipes and also provides updated developments and recent innovations in research and applications of heat pipes. Starting with fundamental presentation of heat pipes, the focus is on oscillating motions and its heat transfer enhancement in a two-phase heat transfer system. The book covers thermodynamic analysis, interfacial phenomenon, thin film evaporation,  theoretical models of oscillating motion and heat transfer of single phase and two-phase flows, primary  factors affecting oscillating motions and heat transfer,  neutron imaging study of oscillating motions in an oscillating heat pipes, and nanofluid’s effect on the heat transfer performance in oscillating heat pipes.  The importance of thermally-excited oscillating motion combined with phase change heat transfer to a wide variety of applications is emphasized. This book is an essential resource and learning tool for senior undergraduate, gradua...

  13. Collection of a radioactive source of $^{83}$Kr to study the gas distribution dynamics in a large GRPC detector

    CERN Multimedia

    An ultra-granular hadronic calorimeter was built using Glass Resistive Plate Chamber (GRPC) detectors as the sensitive medium. The gas of those detectors of $1 \\times 1$ m$^{2}$ each is constrained to be on one side of the detector. To ensure good gas distribution a prototype was built. Such a scheme could be extended to larger GRPC detectors of more than 2 m$^{2}$ if found efficient. To check the performance a radioactive gas could be used in association with the usual gas mixture used to operate the GRPC. The distribution of the radioactive gas can be monitored thanks to the 1 cm$^2$ resolution provided by the embedded electronics used to read out the detector. The radioactive $^{83}$Kr source (obtained from $^{83}$Rb decay) could be produced at the ISOLDE facility and will be used to study larger GRPC detectors at CERN.

  14. Regional intratidal gas distribution in acute lung injury and acute respiratory distress syndrome assessed by electric impedance tomography.

    Science.gov (United States)

    Lowhagen, K; Lundin, S; Stenqvist, O

    2010-12-01

    Regional tidal volume distribution and end-expiratory lung volume (EELV) distribution in patients with acute lung injury and acute respiratory distress syndrome (ALI, ARDS) have previously been investigated using computed tomograpy and electric impedance tomography (EIT). In the present study, we utilized the high temporal resolution of EIT to assess intratidal gas distribution. Sixteen ventilator patients with ALI/ARDS were studied. EIT was used for analysis of intertidal, intratidal and EELV regional distribution. Intratidal regional gas distribution (ITV) was analyzed by dividing the regional tidal impedance signal into eight iso-volume parts. Alveolar pressure/volume curves during ongoing ventilation and volume-dependent compliance during the initial inspiration (Cini) were calculated. A low-pressure (~32 cm H2O) recruitment maneuver and a decremental PEEPtrial were implemented. The increase in EELV was preferentially distributed to non-dependent lung regions. The intratidal gas distribution pattern was similar to the tidal volume distribution following increased PEEP; non-dependent distribution decreased and dependent distribution increased during inspiration. Cini increased, indicating successful recruitment. The distribution varied widely among individual patients. In one patient with a low EELV, the ITV pattern showed that non-dependent distribution increased and dependent distribution decreased. This coincided with minimal improvement in volume-dependent compliance. This patient probably needed higher recruitment pressure. In one patient with a high baseline EELV, there was very little change in regional ITV, and non-dependent Cini decreased. This was probably a patient with low potential recruitability, who required only moderate PEEP. On-line intratidal gas distribution monitoring offers additional information on recruitability and optimal PEEP.

  15. Improvement activities to soil stabilization near Bolivia-Brazil gas pipeline crossing through an embankment over a corrugated drainage pipe, at Km 247 in Mato Grosso do Sul, Brazil; Melhorias para estabilidade do gasoduto Bolivia-Brasil em cruzamento de aterro sobre tubo de drenagem tipo ARMCO, no km 247 em Mato Grosso do Sul

    Energy Technology Data Exchange (ETDEWEB)

    Jorge, Kemal Vieira [TBG - Transportadora Brasileira Gasoduto Bolivia Brasil S.A., Rio de Janeiro, RJ (Brazil); Costa, Cesar Augusto [TBG - Transportadora Brasileira Gasoduto Bolivia Brasil S.A., Campo Grande, MS (Brazil). Gerencia Regional Centro Oeste (CRGO)

    2005-07-01

    A hundred and seventy kilometers from Campo Grande city, on Mato Grosso do Sul State, the Brasil-Bolivia Gas Pipeline crosses a 8,5 meters high landfill, over a drainage systems made of a 2,8 meters of diameter corrugated pipe. This drainage pipe was installed to allow the drainage of the valley, and the landfill above it was built so the Gas pipeline could cross easier the 80 meters deep and 30 degree vertices valley. This paper illustrates the work tasks and solutions taken to monitor and guarantee the integrity of the drainage and landfill structures, as well as the integrity of the Gas Pipeline. Some of the work tasks illustrated are the investigation of the support conditions of the Gas Pipeline, the analysis of a drainage system under the pipeline, on a rocky soil, the analysis of the stability of the landfill, the construction of a gravity retaining walls and the monitoring of the deformations on the drainage pipe. (author)

  16. City of Rio de Janeiro's Gas Distribution Network Conversion Program; Projeto de conversao do Sistema de Distribuicao de Gas Canalizado do Rio de Janeiro

    Energy Technology Data Exchange (ETDEWEB)

    Costa Filho, Manoel A.F.; Pallottino, Joao T. [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil); Margalef, Jose M. [Companhia Distribuidora de Gas do Rio de Janeiro (CEG), Rio de Janeiro, RJ (Brazil)

    2004-07-01

    This paper discusses the Conversion Program of Rio de Janeiro city, from Town Gas to Natural Gas, looking for evaluating its logistic and benefits, highlighting mainly those related to consumer's safety. The Conversion Program is been implemented under Companhia Distribuidora de Gas do Rio de Janeiro (CEG) supervision, with support of Rio de Janeiro State University (UERJ) in service's quality appraisal and conversion technical procedure elaboration and review. This partnership has started in 2001 and 46% of all residential and commercial customers have already been converted up to July 2004. Conversion Program is divided into the following Phases: Design and Planning, Gas Distribution Network Renovation and Adaptation, Revision, Post-Revision, Conversion and Post-Conversion. This Program may serve as model for similar programs, to be developed in other cities where Natural Gas will be distributed, displacing the Liquefied Petroleum Gas (LPG), and it is one contribution to achieve the federal governmental goal of 12%-NG-participation within Brazilian Energetic Matrix in 2010. (author)

  17. Local ISM 3D Distribution and Soft X-ray Background Inferences for Nearby Hot Gas

    Science.gov (United States)

    Puspitarini, L.; Lallement, R.; Snowden, Steven L.; Vergely, J.-L.; Snowden, S.

    2014-01-01

    Three-dimensional (3D) interstellar medium (ISM) maps can be used to locate not only interstellar (IS) clouds, but also IS bubbles between the clouds that are blown by stellar winds and supernovae, and are filled by hot gas. To demonstrate this, and to derive a clearer picture of the local ISM, we compare our recent 3D IS dust distribution maps to the ROSAT diffuse Xray background maps after removal of heliospheric emission. In the Galactic plane, there is a good correspondence between the locations and extents of the mapped nearby cavities and the soft (0.25 keV) background emission distribution, showing that most of these nearby cavities contribute to this soft X-ray emission. Assuming a constant dust to gas ratio and homogeneous 106 K hot gas filling the cavities, we modeled in a simple way the 0.25 keV surface brightness along the Galactic plane as seen from the Sun, taking into account the absorption by the mapped clouds. The data-model comparison favors the existence of hot gas in the solar neighborhood, the so-called Local Bubble (LB). The inferred mean pressure in the local cavities is found to be approx.9,400/cu cm K, in agreement with previous studies, providing a validation test for the method. On the other hand, the model overestimates the emission from the huge cavities located in the third quadrant. Using CaII absorption data, we show that the dust to CaII ratio is very small in those regions, implying the presence of a large quantity of lower temperature (non-X-ray emitting) ionized gas and as a consequence a reduction of the volume filled by hot gas, explaining at least part of the discrepancy. In the meridian plane, the two main brightness enhancements coincide well with the LB's most elongated parts and chimneys connecting the LB to the halo, but no particular nearby cavity is found towards the enhancement in the direction of the bright North Polar Spur (NPS) at high latitude. We searched in the 3D maps for the source regions of the higher energy

  18. Experimental investigation on distribution of mass flux and gas/liquid mixture ratio of airblast coaxial atomizers

    Science.gov (United States)

    Wu, Jinxiang; Liu, Weidong; Zhuang, Fengchen

    1993-06-01

    Airblast coaxial atomizers are widely used in combustion chambers of liquid rocket engines, and the distributions of mass flux and gas/liquid mixture ratio in the downstream of the atomizers are one of the important parameters which influence the performance of combustion. A two-phase impact probe designed by the authors was employed to measure these parameters in a type of airblast coaxial atomizer. Graphs from experimental results show the details of the distribution in the downstream of the atomizers and the influences of the configuration parameters on distribution. The results provides important references for understanding the structure of gas/liquid flow fields and for designing and improving such atomizers.

  19. Optimization combinatorial for expansion of gas distribution networks; Otimizacao combinatoria para expansao de redes de distribuicao de gas

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Wagner Emanoel; Gouvea, Elizabeth Ferreira; Goldbarg, Marco Cesar [Rio Grande do Norte Univ., Natal, RN (Brazil). Dept. de Informatica e Matematica Aplicada]. E-mail: wemano@digi.com.br; beth@dimap.ufrn.br; gold@dimap.ufrn.br

    2003-07-01

    Brazil is in a excellent context for the development of natural gas as energy source. The responsibility of design a network to deliver gas increases with the new investments made every day. However the computer aided design (CAD) technologies for gas network design were poor developed because in EUA and Europe have their gas networks from long time ago, in such that only a little of the potential of computer had been explored for the gas network design. This work studies the use of combinatorial optimization techniques and others techniques from evolutionary computing to find layouts to create and expand a network and make the pipeline optimization looking for costs minimizations and respecting all demands of pressures and flow. (author)

  20. Analysis of a piping system for requalification

    International Nuclear Information System (INIS)

    Hsieh, B.J.; Tang, Yu.

    1992-01-01

    This paper discusses the global stress analysis required for the seismic/structural requalification of a reactor secondary piping system in which minor defects (flaws) were discovered during a detailed inspection. The flaws in question consisted of weld imperfections. Specifically, it was necessary to establish that the stresses at the flawed sections did not exceed the allowables and that the fatigue life remained within acceptable limits. At the same time the piping system had to be qualified for higher earthquake loads than those used in the original design. To accomplish these objectives the nominal stress distributions in the piping system under the various loads (dead load, thermal load, wind load and seismic load) were determined. First a best estimate finite element model was developed and calculations were performed using the piping analysis modules of the ANSYS Computer Code. Parameter studies were then performed to assess the effect of physically reasonable variations in material, structural, and boundary condition characteristics. The nominal stresses and forces so determined, provided input for more detailed analyses of the flawed sections. Based on the reevaluation, the piping flaws were judged to be benign, i.e., the piping safety margins were acceptable inspite of the increased seismic demand. 13 refs