WorldWideScience

Sample records for gas ct cisternograms

  1. Cerebellopontine angle and internal auditory canal: neurovascular anatomy on gas CT cisternograms

    International Nuclear Information System (INIS)

    Bird, C.R.; Hasso, A.N.; Drayer, B.P.; Hinshaw, D.B. Jr.; Thompson, J.R.

    1985-01-01

    The authors reviewed 103 normal gas CT cisternograms to delineate the appearance of normal neurovascular structures in the cerebellopontine angle (CPA) and internal auditory canal (IAC). Cranial nerves VII and VIII were identified in the CPA in 97% of cases, either separately (53%) or as a bundle (44%). Intracanalicular branches of the VIIIth cranial nerve were identified in 20% of cases, and cranial nerve V was visualized in the CPA in 14%. The characteristic vascular loop, usually the anterior inferior cerebellar artery, was visible in 35% of cases, and, in 22% of visualized cases, was in an intracanalicular location. In 10% of cases, greater than 66% of the IAC was occupied by the neurovascular bundle. Familiarity with the normal anatomy and variations seen on gas CT cisternograms is necessary to prevent false-positive interpretations

  2. CT cisternography of the basal cisterns

    International Nuclear Information System (INIS)

    Galanski, M.; Dickob, M.; Wittkowski, W.; Muenster Univ.

    1986-01-01

    Air cisternograms at post mortem and positive contrast cisternograms on patients were performed in order to study intracisternal structures, particularly cranial nerves, as seen on CT. Air and contrast CT cisternograms showed excellent demonstration of the second, third, fifth, sixth, seventh and eighth cranial nerves. The ninth and tenth cranial nerves could not always be separated from each other and demonstration of the first, fourth, eleventh and twelfth cranial nerves was often not possible or was unsatisfactory. With a knowledge of the normal anatomy and of important surrounding structures, the individual cranial nerves are easily identified. The anthropologic baseline appears highly suitable for CT examination of the basal cisterns. The complementary coronal projection is also very valuable. (orig.) [de

  3. Differential diagnosis of frontal lobe atrophy from chronic subdural hematoma or subdural hygroma on CT in aged patients. Usefulness of CT cisternogram

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, Hideaki [Osaka Univ. (Japan). Faculty of Medicine

    1995-02-01

    Metrizamide CT cisternograms (CTC) were performed in order to examine the CSF passage to subarachnoid space, cerebral sulci and Sylvian fissure. The old aged 20 patients (from 63 to 88 years old) with the layer of low density area around bilateral frontal lobe (bi-frontal LDA) in plain CT finding were selected from 2000 aged patients hospitalized in Hanwa-Senboku Hospital. In these 20 patients, it was difficult to differentiate frontal lobe atrophy from the chronic subdural hematoma and subdural hygroma. Conservative therapy was applied in 19 patients for their old age or their complicated diseases. Only 1 patient was operated for subdural hygroma. The 20 patients were investigated in EEGs, severity of dementia, disturbance of consciousness, activity of daily life, their clinical course and prognosis. Only 2 of the 11 patients with type 1 CTC findings (cerebral sulci, Sylvian fissure and bi-frontal LDA were simultaneously enhanced by metrizamide) showed disturbance of consciousness and/or delirium for their serious somatic disorders. All of 6 patients with type 3 CTC findings (only bi-frontal LDA was not enhanced by metrizamide) showed disturbance of consciousness. Three patients with type 2 CTC findings (atypical findings) were reported independently. Subdural disorder elevating intracranial pressure were clarified in the cases with type 3 CTC findings. (author).

  4. Differential diagnosis of frontal lobe atrophy from chronic subdural hematoma or subdural hygroma on CT in aged patients. Usefulness of CT cisternogram

    International Nuclear Information System (INIS)

    Hayashi, Hideaki

    1995-01-01

    Metrizamide CT cisternograms (CTC) were performed in order to examine the CSF passage to subarachnoid space, cerebral sulci and Sylvian fissure. The old aged 20 patients (from 63 to 88 years old) with the layer of low density area around bilateral frontal lobe (bi-frontal LDA) in plain CT finding were selected from 2000 aged patients hospitalized in Hanwa-Senboku Hospital. In these 20 patients, it was difficult to differentiate frontal lobe atrophy from the chronic subdural hematoma and subdural hygroma. Conservative therapy was applied in 19 patients for their old age or their complicated diseases. Only 1 patient was operated for subdural hygroma. The 20 patients were investigated in EEGs, severity of dementia, disturbance of consciousness, activity of daily life, their clinical course and prognosis. Only 2 of the 11 patients with type 1 CTC findings (cerebral sulci, Sylvian fissure and bi-frontal LDA were simultaneously enhanced by metrizamide) showed disturbance of consciousness and/or delirium for their serious somatic disorders. All of 6 patients with type 3 CTC findings (only bi-frontal LDA was not enhanced by metrizamide) showed disturbance of consciousness. Three patients with type 2 CTC findings (atypical findings) were reported independently. Subdural disorder elevating intracranial pressure were clarified in the cases with type 3 CTC findings. (author)

  5. Assessment of neurovascular compression in patients with trigeminal neuralgia with a boundary fusion three-dimensional magnetic resonance cisternogram/angiogram

    International Nuclear Information System (INIS)

    Satoh, Toru; Omi, Megumi; Ohsako, Chika; Onoda, Keisuke; Date, Isao

    2007-01-01

    Precise assessment of the complex nerve-vessel relationship at the root entry zone (REZ) of the trigeminal nerve is useful for the planning of the microvascular decompression (MVD) in patients with trigeminal neuralgia. We have applied a boundary imaging of fusion three-dimensional (3D) magnetic resonance (MR) cisternogram/angiogram. The boundary imaging allows virtual assessment of the spatial relationship of the neurovascular compression at the REZ of the trigeminal nerve. The boundary images depicted complex anatomical relationship of the offending vessels to the trigeminal nerve REZ. The presence of offending vessels, compressive site, and degree of neurovascular compression were assessed from various viewpoints in the cistern and virtually through the brainstem and trigeminal nerve per se. The 3D visualization of the nerve-vessel relationship with fusion images was consistent with the intraoperative findings. The boundary fusion 3D MR cisternogram/angiogram may prove a useful adjunct for the diagnosis and decision-marking process to execute the MVD in patients with trigeminal neuralgia. (author)

  6. CT analysis of intratumoral gas formation after hepatic tumor embolization

    International Nuclear Information System (INIS)

    Kim, Hyun Sook; Ahn, In Oak; Kim, Hyung Jin; Lee, Goo; Chung, Sung Hoon

    1994-01-01

    To evaluate the prevalence and the patterns of sterile gas shown at computed tomography(CT) after transarterial embolization(TAE) for primary hepatic tumor. Among 102 patients who performed TAE for hepatoma, thirty-four in whom follow-up CT was underwent constituted the basis of our study. At CT, we evaluated the patterns and locations of intratumoral gas. We also reviewed the clinical data to exclude an infectious origin of intratumoral gas. Of 34 patients, intratumoral gas was detected in 11 patients(32%), in all of whom Gelfoam was used as an embolic material. The initial tumor size measured at pre-TAE CT was larger in patients with intratumoral gas than in patients without it(p < 0.005). No specific patterns or locations of intratumoral gas were noted on CT scans. No patients had clinical signs and symptoms that suggested infection. Intratumoral gas formation without clinical evidence of infection is not an infrequent finding after TAE for hepatoma, especially when Gelfoam is used and when the tumor is larger in size. This finding may be a part of postinfarction syndrome and should not be misinterpreted as an postprocedural abscess formation

  7. Diagnostic significance of gas distension technique of the stomach with gas-forming agent on CT scan of stomach cancer

    International Nuclear Information System (INIS)

    Rho, Tae Jin; Song, Chang June; Choi, Joong Chan; Park, Cheong Hee; Cho, June Sik; Rhee, Byung Chull

    1988-01-01

    CT is a valuable method for preoperative staging of patients with stomach cancers. However, in patients with poor distension of the stomach and scanty fat between the stomach and adjacent organs, CT findings may indicate a false impression of gastric wall thickening and cannot provide the precise extent of stomach cancer. We studied the usefulness of gastric distension by gas-forming agent in 28 cases of pathologically confirmed gastric cancers on CT. Comparative analysis between CT findings and surgical pathologic findings was done in 22 cases who underwent surgery. The results were as follows; 1. Conventional CT failed to define the wall thickening or masses of the stomach, in 14 cases of 23 advanced gastric cancers, while CT with gas distension technique allowed good visualization in all advanced gastric cancers. 2. In 2 cases of 5 early gastric cancers, CT with gas distension technique could detect focal thickening of the gastric wall, even less than 1cm thickness. 3. Among 13 cases with indistinguishable border between stomach and liver on conventional CT, 7 cases were diagnosed as negative invasion on CT with gas distension technique and 5 cases of these were confirmed by surgery. 4. Among 11 cases with indistinguishable border between stomach and pancreas on conventional CT, 3 cases were diagnosed as negative invasion on CT with gas distension technique, all of which were confirmed by surgery. 5. There was no significant difference between conventional CT and CT with gas distension technique of the stomach to diagnose invasion into transverse colon, transverse colon, transverse mesocolon, lymph node metastasis, and various distant metastasis.

  8. Diagnostic significance of gas distension technique of the stomach with gas-forming agent on CT scan of stomach cancer

    Energy Technology Data Exchange (ETDEWEB)

    Rho, Tae Jin; Song, Chang June; Choi, Joong Chan; Park, Cheong Hee; Cho, June Sik; Rhee, Byung Chull [Chungnam National University College of Medicine, Dajeon (Korea, Republic of)

    1988-10-15

    CT is a valuable method for preoperative staging of patients with stomach cancers. However, in patients with poor distension of the stomach and scanty fat between the stomach and adjacent organs, CT findings may indicate a false impression of gastric wall thickening and cannot provide the precise extent of stomach cancer. We studied the usefulness of gastric distension by gas-forming agent in 28 cases of pathologically confirmed gastric cancers on CT. Comparative analysis between CT findings and surgical pathologic findings was done in 22 cases who underwent surgery. The results were as follows; 1. Conventional CT failed to define the wall thickening or masses of the stomach, in 14 cases of 23 advanced gastric cancers, while CT with gas distension technique allowed good visualization in all advanced gastric cancers. 2. In 2 cases of 5 early gastric cancers, CT with gas distension technique could detect focal thickening of the gastric wall, even less than 1cm thickness. 3. Among 13 cases with indistinguishable border between stomach and liver on conventional CT, 7 cases were diagnosed as negative invasion on CT with gas distension technique and 5 cases of these were confirmed by surgery. 4. Among 11 cases with indistinguishable border between stomach and pancreas on conventional CT, 3 cases were diagnosed as negative invasion on CT with gas distension technique, all of which were confirmed by surgery. 5. There was no significant difference between conventional CT and CT with gas distension technique of the stomach to diagnose invasion into transverse colon, transverse colon, transverse mesocolon, lymph node metastasis, and various distant metastasis.

  9. Disc-like herniation in association with gas collection in the spinal canal: CT evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Tsitouridis, Ioannis [Radiology Department, Papageorgiou General Hospital, Peripheral Rd., Nea Efkarpia, 546 29 Thessaloniki (Greece)]. E-mail: hanjk@radcom.snu.ac.kr; Sayegh, Fares E. [3rd Orthopaedic Department, Aristotle University of Thessaloniki (Greece); Papapostolou, Panagiota [Radiology Department, Papageorgiou General Hospital, Peripheral Rd., Nea Efkarpia, 546 29 Thessaloniki (Greece); Chondromatidou, Stella [Radiology Department, Papageorgiou General Hospital, Peripheral Rd., Nea Efkarpia, 546 29 Thessaloniki (Greece); Goutsaridou, Fotini [Radiology Department, Papageorgiou General Hospital, Peripheral Rd., Nea Efkarpia, 546 29 Thessaloniki (Greece); Emmanouilidou, Maria [Radiology Department, Papageorgiou General Hospital, Peripheral Rd., Nea Efkarpia, 546 29 Thessaloniki (Greece); Sidiropoulou, Maria S. [Radiology Department, Papageorgiou General Hospital, Peripheral Rd., Nea Efkarpia, 546 29 Thessaloniki (Greece); Kapetanos, George A. [3rd Orthopaedic Department, Aristotle University of Thessaloniki (Greece)

    2005-10-01

    Gas production as a part of disk degeneration can occur but rarely causes nerve compression syndromes. Few cases have been reported in which lumbar intraspinal epidural gas cause nerve root compression symptoms. We present 12 cases of gas collection in the spinal canal that were presented to the orthopaedic out-patient department with symptoms of low back pain and sciatica. CT showed the presence of free epidural gas collections adjacent to or over the affected nerve roots. Relief of symptoms was noted with the change of positions, lying down or sleeping. In this study, we conclude that the presence of lumbar intraspinal epidural gas that causes radicular compressing phenomena, can be easily detected with the use of CT.

  10. Disc-like herniation in association with gas collection in the spinal canal: CT evaluation

    International Nuclear Information System (INIS)

    Tsitouridis, Ioannis; Sayegh, Fares E.; Papapostolou, Panagiota; Chondromatidou, Stella; Goutsaridou, Fotini; Emmanouilidou, Maria; Sidiropoulou, Maria S.; Kapetanos, George A.

    2005-01-01

    Gas production as a part of disk degeneration can occur but rarely causes nerve compression syndromes. Few cases have been reported in which lumbar intraspinal epidural gas cause nerve root compression symptoms. We present 12 cases of gas collection in the spinal canal that were presented to the orthopaedic out-patient department with symptoms of low back pain and sciatica. CT showed the presence of free epidural gas collections adjacent to or over the affected nerve roots. Relief of symptoms was noted with the change of positions, lying down or sleeping. In this study, we conclude that the presence of lumbar intraspinal epidural gas that causes radicular compressing phenomena, can be easily detected with the use of CT

  11. Appropriate xenon-inhalation speed in xenon-enhanced CT using the end-tidal gas-sampling method

    International Nuclear Information System (INIS)

    Suga, Sadao; Toya, Shigeo; Kawase, Takeshi; Koyama, Hideki; Shiga, Hayao

    1986-01-01

    This report describes some problems when end-tidal xenon gas is substituted for the arterial xenon concentration in xenon-enhanced CT. The authors used a newly developed xenon inhalator with a xenon-gas-concentration analyzer and performed xenon-enhanced CT by means of the ''arterio-venous shunt'' method and the ''end-tidal gas-sampling'' method simultaneously. By the former method, the arterial build-up rate (K) was obtained directly from the CT slices of a blood circuit passing through the phantom. By the latter method, it was calculated from the xenon concentration of end-tidal gas sampled from the mask. The speed of xenon supply was varied between 0.6 - 1.2 L/min. in 11 patients with or without a cerebral lesion. The results revealed that rapid xenon inhalation caused a discrepancy in the arterial K between the ''shunt'' method and the ''end-tidal'' method. This discrepancy may be responsible for the mixing of inhalated gas and expired gas in respiratory dead space, such as the nasal cavity or the mask. The cerebral blood flow was underestimated because of the higher arterial K in the latter method. Too much slow inhalation, however, was timewasting, and it increased the body motion in the subanesthetic state. Therefore, an inhalation speed of the arterial K of as much as 0.2 was ideal to represent the end-tidal xenon concentration for the arterial K in the ''end-tidal gas-sampling'' method. When attention is given to this point, this method may offer a reliable absolute value in xenon-enhanced CT. (author)

  12. Gas scintillation glass GEM detector for high-resolution X-ray imaging and CT

    Energy Technology Data Exchange (ETDEWEB)

    Fujiwara, T., E-mail: fujiwara-t@aist.go.jp [Research Institute for Measurement and Analytical Instrumentation, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki 305-8568 (Japan); Mitsuya, Y. [Nuclear Professional School, The University of Tokyo, Tokai, Naka, Ibaraki 319-1188 (Japan); Fushie, T. [Radiment Lab. Inc., Setagaya, Tokyo 156-0044 (Japan); Murata, K.; Kawamura, A.; Koishikawa, A. [XIT Co., Naruse, Machida, Tokyo 194-0045 (Japan); Toyokawa, H. [Research Institute for Measurement and Analytical Instrumentation, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki 305-8568 (Japan); Takahashi, H. [Institute of Engineering Innovation, School of Engineering, The University of Tokyo, Bunkyo, Tokyo 113-8654 (Japan)

    2017-04-01

    A high-spatial-resolution X-ray-imaging gaseous detector has been developed with a single high-gas-gain glass gas electron multiplier (G-GEM), scintillation gas, and optical camera. High-resolution X-ray imaging of soft elements is performed with a spatial resolution of 281 µm rms and an effective area of 100×100 mm. In addition, high-resolution X-ray 3D computed tomography (CT) is successfully demonstrated with the gaseous detector. It shows high sensitivity to low-energy X-rays, which results in high-contrast radiographs of objects containing elements with low atomic numbers. In addition, the high yield of scintillation light enables fast X-ray imaging, which is an advantage for constructing CT images with low-energy X-rays.

  13. CT and clinical study for intratumoral gas formation in post transarterial embolization of hepatoma and renal cell carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Katsuragi, M; Matsuo, N; Yoshikawa, K [Nara Medical Univ., Kashihara (Japan)

    1982-09-01

    Thirty-two patients with hepatocellular carcinoma and six patients with renal cell carcinoma for whom the arterial embolization therapy was performed were studied by CT and clinical follow-up for investigating intratumoral gas detected on CT in post-embolization cases. The intratumoral air was found by CT in seven patients with hepatocellular carcinoma and four patients with renal cell carcinoma. The air was composed of a collection of multiple small round gas bubbles in the embolized tumor except in one case where it formed a serpiginous pattern. There was no hematologic nor clinical evidence of liver abscess in all the cases. It was possible to distinguish gas from abscess or fat by a combination of CT and clinical findings.

  14. Clinical significance of gas myelography and CT gas myelography of the thoracic spine and the lumbar spine

    International Nuclear Information System (INIS)

    Yoshinaga, Haruhiko

    1984-01-01

    Basic and clinical applications relating to air myelography of the cervical spine have already been studied and extensively been used as an adjuvant diagnostic method for diseases of the spine and the spinal cord. However, hardly any application and clinical evaluation have been made concerning gas myelography of the thoracic spine and the lumbar spine. The author examined X-ray findings of 183 cases with diseases of the thoracic spine and the lumbar spine, including contral cases. Gas X-ray photography included simple profile, forehead tomography, sagittal plane, and CT section. Morphological characteristics of normal X-ray pictures of the throacic spine and the lumbar spine were explained from 54 control cases, and all the diameters of the subarachnoidal space from the anterior to the posterior part were measured. X-ray findings were examined on pathological cases, namely 22 cases with diseases of the throacic spine and 107 cases with diseases of the lumbar spine, and as a result these were useful for pathological elucidation of spinal cord tumors, spinal carries, yellow ligament ossification, lumbar spinal canal stenosis, hernia of intervertebral disc, etc. Also, CT gas myelography was excellent in stereoobservation of the spine and the spinal cord in spinal cord tumors, yellow ligament ossification, and spinal canal stenosis. On the other hand, it is not suitable for the diagnoses of intraspinal vascular abnormality, adhesive arachinitis, and running abnormality of the cauda equina nerve and radicle. Gas myelography of the thoracic spine and the lambar spine, is very useful in clinics when experienced techniques are used in photographic conditions, and diagnoses are made, well understanding the characteristics of gas pictures. Thus, its application has been opened to selection of an operative technique, determination of operative ranges, etc. (J.P.N.)

  15. Clinical significance of gas myelography and CT gas myelography of the thoracic spine and the lumbar spine

    Energy Technology Data Exchange (ETDEWEB)

    Yoshinaga, Haruhiko (Tokyo Medical Coll. (Japan))

    1984-05-01

    Basic and clinical applications relating to air myelography of the cervical spine have already been studied and extensively been used as an adjuvant diagnostic method for diseases of the spine and the spinal cord. However, hardly any application and clinical evaluation have been made concerning gas myelography of the thoracic spine and the lumbar spine. The author examined X-ray findings of 183 cases with diseases of the thoracic spine and the lumbar spine, including contral cases. Gas X-ray photography included simple profile, forehead tomography, sagittal plane, and CT section. Morphological characteristics of normal X-ray pictures of the throacic spine and the lumbar spine were explained from 54 control cases, and all the diameters of the subarachnoidal space from the anterior to the posterior part were measured. X-ray findings were examined on pathological cases, namely 22 cases with diseases of the throacic spine and 107 cases with diseases of the lumbar spine, and as a result these were useful for pathological elucidation of spinal cord tumors, spinal carries, yellow ligament ossification, lumbar spinal canal stenosis, hernia of intervertebral disc, etc. Also, CT gas myelography was excellent in stereo observation of the spine and the spinal cord in spinal cord tumors, yellow ligament ossification, and spinal canal stenosis. On the other hand, it is not suitable for the diagnoses of intraspinal vascular abnormality, adhesive arachinitis, and running abnormality of the cauda equina nerve and radicle. Gas myelography of the thoracic spine and the lambar spine, is very useful in clinics when experienced techniques are used in photographic conditions, and diagnoses are made, well understanding the characteristics of gas pictures. Thus, its application has been opened to selection of an operative technique, determination of operative ranges, etc.

  16. CT finding of emphysematous gastritis

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Sang Won; Juhn, Jae Ryang; Cha, Seong Sook; Eun, Tchoong Kie; Chung, Duck Hwan [Inje Medical College Paik HospitalYonsei University College of Medicine, Seoul (Korea, Republic of)

    1988-12-15

    Emphysematous gastritis is a rare entity of infectious gastritis caused by gas-forming organisms and only 32 cases have been reported. CT is helpful in the diagnosis particularly in mild cases that there is only a small amount of gas. Typical CT findings of emphysematous gastritis are gas bubbles within the irregular thickened gastric wall and dilated stomach filled with secretions, debris and a large amount of gas. We report a case that was diagnosed by CT and operation.

  17. CT finding of emphysematous gastritis

    International Nuclear Information System (INIS)

    Ahn, Sang Won; Juhn, Jae Ryang; Cha, Seong Sook; Eun, Tchoong Kie; Chung, Duck Hwan

    1988-01-01

    Emphysematous gastritis is a rare entity of infectious gastritis caused by gas-forming organisms and only 32 cases have been reported. CT is helpful in the diagnosis particularly in mild cases that there is only a small amount of gas. Typical CT findings of emphysematous gastritis are gas bubbles within the irregular thickened gastric wall and dilated stomach filled with secretions, debris and a large amount of gas. We report a case that was diagnosed by CT and operation.

  18. Appropriate xenon-inhalation time in xenon-enhanced CT using the end-tidal gas-sampling method

    Energy Technology Data Exchange (ETDEWEB)

    Asada, Hideo; Furuhata, Shigeru; Onozuka, Satoshi; Uchida, Koichi; Fujii, Koji; Suga, Sadao; Kawase, Takeshi; Toya, Shigeo; Shiga, Hayao

    1988-12-01

    For the end-tidal gas-sampling method of xenon-enhanced CT (Xe-CT), the respective functional images of K, lambda, and the regional cerebral blood flow (rCBF) were studied and compared using the data at 7-, 10-, 15- and 25-minute inhalations. The most appropriate inhalation time of xenon gas was evaluated in 14 clinical cases. An end-tidal xenon curve which represents the arterial xenon concentration was monitored with a xenon analyzer; the xenon concentration was gradually increased to a level of 50% by using a xenon inhalator with a closed circuit to prevent the overestimation of the xenon concentration sampled from the mask. Serial CT scans were taken over a period of 25 minutes of inhalation. The functional images of K, lambda, and rCBF were calculated for serial CT scans for 7, 10, 15 and 25 minutes using Fick's equation. Those various images and absolute values were then compared. The rCBF value of a 15-minute inhalation was approximately 15% greater than that of 25 minutes, while the values of K, lambda, rCBF from a 15-minute inhalation were significantly correlated to those from 25 minutes. The regression line made it possible to estimate 25-minute inhalation values from those of 15 minutes. In imaging, the rCBF mapping of the 15-minute inhalation was found to be more reliable than that of 25 minutes. This study suggests that the minimal time of xenon inhalation is 15 minutes for the end-tidal gas-sampling method. A longer inhalation may be necessary for the estimation of rCBF in the low-flow area, such as the white matter or the pathological region.

  19. Comparison of 133Xe gas dynamic SPECT and thin-section CT in patients with pulmonary emphysema

    International Nuclear Information System (INIS)

    Takahashi, Kazue; Satoh, Katashi; Ohkawa, Motoomi

    2001-01-01

    We assessed 133 Xe gas dynamic single photon emission computed tomography (SPECT) by comparing washout axial images with thin-section CT (TSCT) in patients with pulmonary emphysema. Twenty-three patients were studied. All patients were diagnosed as having pulmonary emphysema on the basis of TSCT. We compared TSCT of upper, middle and lower lung fields with 133 Xe gas dynamic SPECT axial images at the corresponding levels during the 3 to 4 minutes of washout phase. If the degree of 133 Xe gas retention or TSCT finding of ventral and dorsal parts was not the same, the images were divided into two parts. A total of 174 lesions in 23 cases were examined, but 3 lesions having no retention of 133 Xe gas at equilibrium phase were excluded. The results showed that: there were 37 lesions (21.6%) with equivalent severity on both images; there were 42 lesions (24.5%) with more severity on 133 Xe gas dynamic SPECT than on TSCT; and there were 92 lesions (53.8%) with more severity on TSCT than on 133 Xe gas dynamic SPECT. The severity on 133 Xe gas dynamic SPECT and TSCT was not always compatible. One of the reasons for the variable 133 Xe gas retention even when the lesion had the same severity on TSCT, may be bronchial stricture which cannot be seen on TSCT. By comparison of axial images of 133 Xe gas dynamic SPECT with CT images, we could recognize the areas of 133 Xe gas retention in detail. Results suggest that 133 Xe gas dynamic SPECT can be useful to identify ventilation impairment in pulmonary emphysema. (author)

  20. Comparison of air space measurement imaged by CT, small-animal CT, and hyperpolarized Xe MRI

    Science.gov (United States)

    Madani, Aniseh; White, Steven; Santyr, Giles; Cunningham, Ian

    2005-04-01

    Lung disease is the third leading cause of death in the western world. Lung air volume measurements are thought to be early indicators of lung disease and markers in pharmaceutical research. The purpose of this work is to develop a lung phantom for assessing and comparing the quantitative accuracy of hyperpolarized xenon 129 magnetic resonance imaging (HP 129Xe MRI), conventional computed tomography (HRCT), and highresolution small-animal CTCT) in measuring lung gas volumes. We developed a lung phantom consisting of solid cellulose acetate spheres (1, 2, 3, 4 and 5 mm diameter) uniformly packed in circulated air or HP 129Xe gas. Air volume is estimated based on simple thresholding algorithm. Truth is calculated from the sphere diameters and validated using μCT. While this phantom is not anthropomorphic, it enables us to directly measure air space volume and compare these imaging methods as a function of sphere diameter for the first time. HP 129Xe MRI requires partial volume analysis to distinguish regions with and without 129Xe gas and results are within %5 of truth but settling of the heavy 129Xe gas complicates this analysis. Conventional CT demonstrated partial-volume artifacts for the 1mm spheres. μCT gives the most accurate air-volume results. Conventional CT and HP 129Xe MRI give similar results although non-uniform densities of 129Xe require more sophisticated algorithms than simple thresholding. The threshold required to give the true air volume in both HRCT and μCT, varies with sphere diameters calling into question the validity of thresholding method.

  1. Necrotizing fasciitis : plain radiographic and CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chang Dae; Park, Jeong Hee; Jeon, Hae Jeong; Lim, Jong Nam; Heo, Tae Haeng; Park, Dong Rib [Konkuk Univ. College of Medicine, Seoul (Korea, Republic of)

    1996-11-01

    To evaluate the plain radiographic and CT findings of the necrotizing fasciitis. We retrospectively reviewed the radiologic findings of 4 cases with necrotizing fasciitis. Three cases were proven pathologically. We evaluated pattern and extent of the gas shadows in plain films. CT findings were analysed, with emphasis on : (a) gas pattern, (b) extent, (c) location and involved site, (d) associated focal abscess, and (e) swelling of the adjacent muscles. On plain radiographs, four cases showed streaky or mottled gas densities in the pelvis, three cases in the perineum, one case in the abdomen, and two cases in the thigh. On CT images, gas pattern was mottled and streaky appearance with swelling of the adjacent muscles. Gas shadows located in the extraperitoneal space in four cases, fascial layer in four cases, and subcutaneous layer in four cases. There were gas shadows in pelvic wall, perineum, abdominal wall, buttock, thigh, and scrotum. Focal low density lesion suggestive of focal abscess was not visualized. Plain radiography is useful for early diagnosis of the necrotizing fasciitis and CT is very useful for detection of precise location and extent of the disease. CT is also useful for differentiation of necrotizing fasciitis from focal abscess and cellulitis.

  2. Elimination of CT-detected gas bubbles derived from decompression illness with abdominal symptoms after a short hyperbaric oxygen treatment in a monoplace chamber: a case report.

    Science.gov (United States)

    Oyaizu, Takuya; Enomoto, Mitsuhiro; Tsujimoto, Toshihide; Kojima, Yasushi; Okawa, Atsushi; Yagishita, Kazuyoshi

    2017-01-01

    We report the case of a 54-year-old male compressed-air worker with gas bubbles detected by computed tomography (CT). He had complained of strong abdominal pain 30 minutes after decompression after working at a pressure equivalent to 17 meters of sea water for three hours. The initial CT images revealed gas bubbles in the intrahepatic portal vein, pulmonary artery and bilateral femoral vein. After the first hyperbaric oxygen treatment (HBO₂ at 2.5 atmospheres absolute/ATA for 150 minutes), no bubbles were detected on repeat CT examination. The patient still exhibited abdominal distension, mild hypesthesia and slight muscle weakness in the upper extremities. Two sessions of U.S. Navy Treatment Table 6 (TT6) were performed on Days 6 and 7 after onset. The patient recovered completely on Day 7. This report describes the important role of CT imaging in evaluating intravascular gas bubbles as well as eliminating the diagnosis of other conditions when divers or compressed-air workers experience uncommon symptoms of decompression illness. In addition, a short treatment table of HBO₂ using non-TT6 HBO₂ treatment may be useful to reduce gas bubbles and the severity of decompression illness in emergent cases. Copyright© Undersea and Hyperbaric Medical Society.

  3. Gas-contrasted computed tomography for evaluation of mediastinal lesions

    Energy Technology Data Exchange (ETDEWEB)

    Mitsuoka, A; Reshad, K; Kitano, M; Ishii, S [Tenri Hospital, Nara (Japan)

    1981-03-01

    An application of gas-contrasted computed tomography (CT) was investigated for evaluation of mediastinal lesions. Findings of the gas-contrasted CT were compared with those of usual CT or conventional pneumomediastinography in nine patients with myasthenia gravis, four patients with mediastinal tumor, and five patients with other mediastinal lesions. As a result, the following results were obtained. 1) In examination for the thymus in myasthenia gravis, the shape of the thymus tissue was most accurately recognized by gas-contrasted CT, which enable one to discriminate the thymus tissue from the fatty tissue of the surrounding mediastinum with injected gas. 2) Gas-contrasted CT could most accurately evaluate adhesion or invasion of the mediastinal tumor to the surrounding organs. At the exact site of adhesion, injected gas to the mediastinum did not separate the tumor from the surroundings. Such diagnostic significance was considered to be available also to mediastinal lymphnode metastasis or suspected invasion of the malignant tumor from outside the mediastinum. 3) These findings of gas-contrasted CT were correlated well to those at operation. Hence, it was concluded that this diagnostic method presents good informations in assessing the resectability of the tumor or preoperative determination of the operation procedure. 4) However, it seemed difficult to distinguish between inflammatory (benign) adhesion and invasive (malignant) one even by gas-contrasted CT. 5) Finally, it was suggested that gas-contrasted CT might be widely adopted for clarification of lesions other than the mediastinal ones.

  4. Gas-contrasted computed tomography for evaluation of mediastinal lesions

    International Nuclear Information System (INIS)

    Mitsuoka, Akio; Reshad, K.; Kitano, Morihisa; Ishii, Shoukei

    1981-01-01

    An application of gas-contrasted computed tomography (CT) was investigated for evaluation of mediastinal lesions. Findings of the gas-contrasted CT were compared with those of usual CT or conventional pneumomediastinography in nine patients with myasthenia gravis, four patients with mediastinal tumor, and five patients with other mediastinal lesions. As a result, the following results were obtained. 1) In examination for the thymus in myasthenia gravis, the shape of the thymus tissue was most accurately recognized by gas-contrasted CT, which enable one to discriminate the thymus tissue from the fatty tissue of the surrounding mediastinum with injected gas. 2) Gas-contrasted CT could most accurately evaluate adhesion or invasion of the mediastinal tumor to the surrounding organs. At the exact site of adhesion, injected gas to the mediastinum did not separate the tumor from the surroundings. Such diagnostic significance was considered to be available also to mediastinal lymphnode metastasis or suspected invasion of the malignant tumor from outside the mediastinum. 3) These findings of gas-contrasted CT were correlated well to those at operation. Hence, it was concluded that this diagnostic method presents good informations in assessing the resectability of the tumor or preoperative determination of the operation procedure. 4) However, it seemed difficult to distinguish between inflammatory (benign) adhesion and invasive (malignant) one even by gas-contrasted CT. 5) Finally, it was suggested that gas-contrasted CT might be widely adopted for clarification of lesions other than the mediastinal ones. (author)

  5. CT and sonographic diagnosis of retained surgical sponge

    International Nuclear Information System (INIS)

    Matsumoto, Syunro; Aikawa, Hisayuki; Miyake, Hidetoshi; Mori, Hiromu; Maeda, Tohru; Nishimura, Hiro; Monzen, Yoshio; Ashizawa, Akira; Isomoto, Ichiro.

    1990-01-01

    Seven cases of pathologically proven retained surgical sponge were reviewed and classified into four types, depending on CT and US findings. CT showed a mass with tiny gas bubbles, and sonogram showed an echogenic area with strong posterior shadow (Type I). CT showed an irregular high density mass with no gas bubble, and sonogram showed an echogenic area with strong posterior shadow (Type II). CT showed a low density mass with irregular internal high density areas, and somogram showed a cystic mass with zigzag internal components (Type III). CT showed an eliptic high density mass with low density area internally. Judging from the experiment and operative findings, these patterns were decided by the number and status of the gauze, volume of the exudate and hematoma, and status of the granulation. The author concludes that these characteristic CT and US findings, together with a history of surgery, permit the correct diagnosis of retained surgical sponge. (author)

  6. CT after transsphenoidal surgery

    International Nuclear Information System (INIS)

    Tazawa, Satoru

    1991-01-01

    Two hundred and ten CT studies of 95 patients after transsphenoidal surgery were reviewed. Spheno-ethmoid opacificaiton, intrasellar hematoma and gas bubbles were noted within 2 weeks after surgery. Bone defect of the sellar floor and bone stent were seen on coronal scans in most cases. The packing material frequently disappeared on follow-up studies. Hormonal assessment of the functioning tumor, according to which the effect of treatment was evaluated, was correlated with CT findings. Because differentiation between postoperative changes and residual mass was difficult, there was no definite CT criteria to indicate residual functioning tumor except upward convexity of the diaphragma sellae on CT more than 3 months after surgery. Initial follow up CT study is recommended to be performed at about 3 months after surgery, at which time the immediate postoperative inflammatory changes have been disappeared. The incidence of recurrence was 3/47 (6%), which was shown on follow-up CT from 4 to 10 years after surgery. Therefore, subsequent CT study should be done in every year or two, taking the clinical symptoms and hormonal data into consideration. (author)

  7. CT after transsphenoidal surgery

    Energy Technology Data Exchange (ETDEWEB)

    Tazawa, Satoru [Tohoku Univ., Sendai (Japan). School of Medicine

    1991-03-01

    Two hundred and ten CT studies of 95 patients after transsphenoidal surgery were reviewed. Spheno-ethmoid opacificaiton, intrasellar hematoma and gas bubbles were noted within 2 weeks after surgery. Bone defect of the sellar floor and bone stent were seen on coronal scans in most cases. The packing material frequently disappeared on follow-up studies. Hormonal assessment of the functioning tumor, according to which the effect of treatment was evaluated, was correlated with CT findings. Because differentiation between postoperative changes and residual mass was difficult, there was no definite CT criteria to indicate residual functioning tumor except upward convexity of the diaphragma sellae on CT more than 3 months after surgery. Initial follow up CT study is recommended to be performed at about 3 months after surgery, at which time the immediate postoperative inflammatory changes have been disappeared. The incidence of recurrence was 3/47 (6%), which was shown on follow-up CT from 4 to 10 years after surgery. Therefore, subsequent CT study should be done in every year or two, taking the clinical symptoms and hormonal data into consideration. (author).

  8. CT of abdominal abscesses

    International Nuclear Information System (INIS)

    Korobkin, M.T.

    1987-01-01

    The imaging search for a suspected abdominal abscess is common in hospitalized patients, especially after recent abdominal surgery. This paper examines the role of CT in the detection, localization, and treatment of abdominal abscess. The accuracy, limitations, and technical aspects of CT in this clinical setting are discussed. The diagnosis of an abscess is based on the demonstration of a circumscribed abnormal fluid collection. Although percutaneous aspiration with gram stain and culture is usually indicated to differentiate abscess from other fluid collections, the CT-based detection of extraluminal gas bubbles makes the diagnosis of an abscess highly likely. CT is compared with conventional radiographic studies, US, and radio-nuclide imaging. Specific CT and clinical features of abscesses in the following sites are emphasized: subphrenic space, liver, pancreas, kidneys, psoas muscle, appendix, and colonic diverticula. Most abdominal abscesses can be successfully treated with percutaneous drainage techniques. The techniques, results, and limitations of percutaneous abscess drainage are reviewed

  9. Sciatica caused by lumbar epidural gas.

    Science.gov (United States)

    Belfquih, Hatim; El Mostarchid, Brahim; Akhaddar, Ali; gazzaz, Miloudi; Boucetta, Mohammed

    2014-01-01

    Gas production as a part of disc degeneration can occur but rarely causes nerve compression syndromes. The clinical features are similar to those of common sciatica. CT is very useful in the detection of epidural gas accumulation and nerve root compression. We report a case of symptomatic epidural gas accumulation originating from vacuum phenomenon in the intervertebral disc, causing lumbo-sacral radiculopathy. A 45-year-old woman suffered from sciatica for 9 months. The condition worsened in recent days. Computed tomography (CT) demonstrated intradiscal vacuum phenomenon, and accumulation of gas in the lumbar epidural space compressing the dural sac and S1 nerve root. After evacuation of the gas, her pain resolved without recurrence.

  10. Pulmonary alveolar proteinosis: Quantitative CT and pulmonary functional correlations

    Energy Technology Data Exchange (ETDEWEB)

    Guan, Yubao, E-mail: yubaoguan@163.com [Department of Radiology, the First Affiliated Hospital of Guangzhou Medical College, Guangzhou 510120 (China); State Key Laboratory of Respiratory Disease, Guangzhou 510120 (China); Zeng, Qingsi [Department of Radiology, the First Affiliated Hospital of Guangzhou Medical College, Guangzhou 510120 (China); Yang, Haihong; Zheng, Jinping; Li, Shiyue; Gao, Yi [State Key Laboratory of Respiratory Disease, Guangzhou 510120 (China); Deng, Yu [Department of Radiology, the First Affiliated Hospital of Guangzhou Medical College, Guangzhou 510120 (China); Mei, Jiang [State Key Laboratory of Respiratory Disease, Guangzhou 510120 (China); He, Jianxing, E-mail: jianxing63@163.com [State Key Laboratory of Respiratory Disease, Guangzhou 510120 (China); Zhong, Nanshan, E-mail: nanshan@vip.163.com [State Key Laboratory of Respiratory Disease, Guangzhou 510120 (China)

    2012-09-15

    Objective: We assessed the relationship between quantitative computer tomography (qCT) and the pulmonary function test (PFT) or blood gas analysis in pulmonary alveolar proteinosis (PAP) patients, as well as the utility of these analyses to monitor responses to whole lung lavage (WLL) therapy. Methods: Thirty-eight PAP patients simultaneously received a CT scan and PFT. Fifteen of these patients, undergoing sequential WLL for a total of 20 lavages, also underwent chest CT scans and blood gas analysis before and after WLL, and 14 of 15 patients underwent simultaneous PFT analysis. Differences between the qCT and PFT results were analyzed by canonical correlation. Results: PAP patients with low predicted values for FVC, FEV1, D{sub LCO} and D{sub LCO}/VA indicated small airspace volume and mean lung inflation, low airspace volume/total lung volume ratio and high mean lung density. Correlation and regression analysis revealed a strong correlation between D{sub LCO} and PaO{sub 2} values with CT results. The qCT results indicated that WLL significantly decreased lung weights and mean lung densities, and improved the total airspace volume/total lung volume ratios and mean lung inflations. Conclusion: Quantitative CT may be a sensitive tool for measuring the response of PAP patients to medical interventions such as WLL.

  11. Portal-venous gas unrelated to mesenteric ischemia

    International Nuclear Information System (INIS)

    Wiesner, Walter; Mortele, Koenraad J.; Ji, Hoon; Ros, Pablo R.; Glickman, Jonathan N.

    2002-01-01

    The aim of this study was to report on 8 patients with all different non-ischemic etiologies for portal-venous gas and to discuss this rare entity and its potentially misleading CT findings in context with a review of the literature. The CT examinations of eight patients who presented with intrahepatic portal-venous gas, unrelated to bowel ischemia or infarction, were reviewed and compared with their medical records with special emphasis on the pathogenesis and clinical impact of portal-venous gas caused by non-ischemic conditions. The etiologies for portal-venous gas included: abdominal trauma (n=1); large gastric cancer (n=1); prior gastroscopic biopsy (n=1); prior hemicolectomy (n=1); graft-vs-host reaction (n=1); large paracolic abscess (n=1); mesenteric recurrence of ovarian cancer superinfected with clostridium septicum (n=1); and sepsis with Pseudomonas aeruginosa (n=1). The clinical outcome of all patients was determined by their underlying disease and not negatively influenced by the presence of portal-venous gas. Although the presence of portal-venous gas usually raises the suspicion of bowel ischemia and/or intestinal necrosis, this CT finding may be related to a variety of non-ischemic etiologies and pathogeneses as well. The knowledge about these conditions may help to avoid misinterpretation of CT findings, inappropriate clinical uncertainty and unnecessary surgery in certain cases. (orig.)

  12. CT images of gossypiboma

    International Nuclear Information System (INIS)

    Jeon, Hae Jeong; Lim, Jong Nam; Choi, Young Chil; Park, Jeong Hee

    1994-01-01

    Surgical sponges retained after laparotomy can cause serious problem if they were not be identified in early state. In these circumstances abdominal CT yields the accurate diagnostic images. The purpose of this report is to present highly indicative findings permitting correct preoperative diagnosis of the gossypiboma. We experienced three cases in which CT showed the images sufficiently characteristic to suggest the correct preoperative diagnosis. We evaluated retrospectively the radiological images of gossypiboma confirmed by operation. Three patients were admitted due to palpable masses. Two female patients had medical histories of cesarean sections and a male patient had been operated due to malignant fibrous histiocytoma, previously. Abdominal CT scan of one case revealed huge ovoid hypodense mass with enhanced peripheral rim. Calcific spots and whirl-like stripes were noted within the lesion. Towel was found in pathologic specimen. CT images of two patients showed well-encapsulated, mixed fluid and soft tissue density mass with several gas bubbles. Surgical sponges were found within abscesses. The authors conclude that these characteristic CT findings and careful histories of surgery are very useful for correct pre-operative diagnosis and permit the guideline for the optimal plan of the surgical treatment

  13. CT images of gossypiboma

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Hae Jeong; Lim, Jong Nam; Choi, Young Chil; Park, Jeong Hee [College of Medicine, Kon-Kuk University, Seoul (Korea, Republic of)

    1994-04-15

    Surgical sponges retained after laparotomy can cause serious problem if they were not be identified in early state. In these circumstances abdominal CT yields the accurate diagnostic images. The purpose of this report is to present highly indicative findings permitting correct preoperative diagnosis of the gossypiboma. We experienced three cases in which CT showed the images sufficiently characteristic to suggest the correct preoperative diagnosis. We evaluated retrospectively the radiological images of gossypiboma confirmed by operation. Three patients were admitted due to palpable masses. Two female patients had medical histories of cesarean sections and a male patient had been operated due to malignant fibrous histiocytoma, previously. Abdominal CT scan of one case revealed huge ovoid hypodense mass with enhanced peripheral rim. Calcific spots and whirl-like stripes were noted within the lesion. Towel was found in pathologic specimen. CT images of two patients showed well-encapsulated, mixed fluid and soft tissue density mass with several gas bubbles. Surgical sponges were found within abscesses. The authors conclude that these characteristic CT findings and careful histories of surgery are very useful for correct pre-operative diagnosis and permit the guideline for the optimal plan of the surgical treatment.

  14. Ventilation imaging of the paranasal sinuses using xenon-enhanced dynamic single-energy CT and dual-energy CT: a feasibility study in a nasal cast

    Energy Technology Data Exchange (ETDEWEB)

    Thieme, Sven F.; Helck, Andreas D.; Reiser, Maximilian F.; Johnson, Thorsten R.C. [Ludwig Maximilians University Hospital Munich, Institute for Clinical Radiology, Munich (Germany); Moeller, Winfried; Eickelberg, Oliver [Institute for Lung Biology and Disease (iLBD) and Comprehensive Pneumology Center (CPC), Helmholtz Zentrum Muenchen, Neuherberg, Munich (Germany); Becker, Sven [Ludwig-Maximilians-Universitaet, Department of Otorhinolaryngology - Head and Neck Surgery, Munich (Germany); Schuschnig, Uwe [Pari Pharma GmbH, Graefelfing (Germany)

    2012-10-15

    To show the feasibility of dual-energy CT (DECT) and dynamic CT for ventilation imaging of the paranasal sinuses in a nasal cast. In a first trial, xenon gas was administered to a nasal cast with a laminar flow of 7 L/min. Dynamic CT acquisitions of the nasal cavity and the sinuses were performed. This procedure was repeated with pulsating xenon flow. Local xenon concentrations in the different compartments of the model were determined on the basis of the enhancement levels. In a second trial, DECT measurements were performed both during laminar and pulsating xenon administration and the xenon concentrations were quantified directly. Neither with dynamic CT nor DECT could xenon-related enhancement be detected in the sinuses during laminar airflow. Using pulsating flow, dynamic imaging showed a xenon wash-in and wash-out in the sinuses that followed a mono-exponential function with time constants of a few seconds. Accordingly, DECT revealed xenon enhancement in the sinuses only after pulsating xenon administration. The feasibility of xenon-enhanced DECT for ventilation imaging was proven in a nasal cast. The superiority of pulsating gas flow for the administration of gas or aerosolised drugs to the paranasal sinuses was demonstrated. (orig.)

  15. Evaluation of MR cisternography of the cerebellopontine angle using a balanced fast-field-echo sequence: preliminary findings

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiya, Kazuhiro; Aoki, Chinatsu; Hachiya, Junichi [Department of Radiology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka, 181-8611, Tokyo (Japan)

    2004-02-01

    We evaluated the feasibility of MR cisternography by the balanced fast-field-echo (bFFE) sequence, comparing with that by a turbo-spin-echo (TSE) sequence, for cerebellopontine angle lesions on a 1.5-T imager (Gyroscan Intera, Philips, Best, The Netherlands). The bFFE MR cisternograms depicted target cranial nerves with less cerebrospinal fluid pulsation artifacts than TSE cisternograms and visualized an acoustic schwannoma in 6 of 44 patients with suspicion and a causative vessel of hemifacial spasm in all of 3 patients in a short scanning time (1 min 53 s). The bFFE sequence can be promising for MR cisternography in the diagnosis of cerebellopontine angle lesions. (orig.)

  16. CT studies of mesentery and related vascular findings in strangulating intestinal obstruction

    International Nuclear Information System (INIS)

    Li Wenhua; Cao Qingxuan; Yang Shifeng; Li Jianhai; Lu Shenglin; Zhang Qiang; Wu Tian

    2006-01-01

    Objective: To investigate the CT appearance of mesentery and related vascular (MRV) findings in strangulating obstruction (SO) and evaluate the value of CT examination for diagnosing SO. Methods: Thirty patients with SO were included in the investigation. The diagnosis was confirmed by operation in 26 cases and 4 cases by clinic. The cause of SO included adhesion in 9 cases, volvulus in 8 cases, intussusception in 6 cases, infarction of mesenteric vesseles in 4 cases, and internal hernia in 3 cases, respectively. All patients was examined with CT and 20 of them with enhanced CT. Results: Eleven items of CT findings were revealed in these patients. The findings could be divided into 3 types: (1) direct signs: including embolism of mesenteric vasculature in 2 cases and mesenteric edema and related vascular enlargement in 19 cases. (2)indirect signs: including bowel wall edema and thickenning in 24 cases, abnormal enhancement of the wall in 6 cases, massive fluid in the bowel in 13 cases, abnormal form of loops in 10 cases, and hemorrhage of bowel wall and mesentery in 1 case each. (3) complicated signs: including intramural gas in 3 cases, intrahepatic portal veins gas in 1 case, gas in mesentery in 1 case, and ascites and pneumoperitoneum in 11 cases. Conclusion: The CT findings of mesenteric edema, ischemia and infarction are reliable and characteristic signs for diagnosing SO. The diagnosis of SO can be correctly made before operation if these signs are recognized, at the same time, CT may demonstrate some complications which can not be revealed by traditional X-ray examinations. (authors)

  17. Pneumatosis intestinalis: CT findings and clinical features

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hye Lin; Lee, Hae Kyung; Park, Seong Jin; Yi, Boem Ha; Ko, Bong Min; Hong, Hyun Sook; Paik, Sang Hyun [Soonchunhyang University Hospital Bucheon, Bucheon (Korea, Republic of)

    2008-02-15

    The purpose of this study is to evaluate the CT findings and clinical features of patients with pneumatosis intestinalis. From January 2001 to October 2007, 15 patients with pneumatosis intestinalis were diagnosed by the use of CT. We analyzed the clinical features and CT findings to assess the involvement site, the presence of portal and mesenteric vein gas, and the existence of accompanied ischemic change. Of the 15 patients, five patients had end stage renal disease (33.3%), two patients underwent a gastrectomy, one patient underwent a laminectomy, one patient had tuberculous enteritis, one patient had lung cancer and one patient had pneumonia. Four patients presented with no specific disease. There was portal or mesenteric venous gas in six cases, and strangulation or an ischemic change of the bowel in five cases. Otherwise, pneumatosis intestinalis was associated with hydropneumoperitoneum in two cases, pneumoperitoneum in one case and a single case of perforated appendicitis. Nine patients underwent surgery for ischemic change of the bowel, pneumoperitoneum, appendicitis, and a clinical sign of panperitonitis. Among the remaining six patients, three patients recovered and were discharged, and three patients expired during progression of the disease. End stage renal disease is the most common condition associated with pneumatosis intestinalis. The presence of portomesenteric venous gas, ischemic change of the bowel, and linear pneumatosis intestinalis are indicative of a poor prognosis.

  18. Normal pediatric postmortem CT appearances

    Energy Technology Data Exchange (ETDEWEB)

    Klein, Willemijn M.; Bosboom, Dennis G.H.; Koopmanschap, Desiree H.J.L.M. [Radboud University Medical Center, Department of Radiology and Nuclear Medicine, Nijmegen (Netherlands); Nievelstein, Rutger A.J. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Nikkels, Peter G.J. [University Medical Center Utrecht, Department of Pathology, Utrecht (Netherlands); Rijn, Rick R. van [Academic Medical Center, Department of Radiology, Amsterdam (Netherlands)

    2015-04-01

    Postmortem radiology is a rapidly developing specialty that is increasingly used as an adjunct to or substitute for conventional autopsy. The goal is to find patterns of disease and possibly the cause of death. Postmortem CT images bring to light processes of decomposition most radiologists are unfamiliar with. These postmortem changes, such as the formation of gas and edema, should not be mistaken for pathological processes that occur in living persons. In this review we discuss the normal postmortem thoraco-abdominal changes and how these appear on CT images, as well as how to differentiate these findings from those of pathological processes. (orig.)

  19. Postmortem abdominal CT: Assessing normal cadaveric modifications and pathological processes

    International Nuclear Information System (INIS)

    Charlier, P.; Carlier, R.; Roffi, F.; Ezra, J.; Chaillot, P.F.; Duchat, F.; Huynh-Charlier, I.; Lorin de la Grandmaison, G.

    2012-01-01

    Purpose: To investigate the interest of postmortem non-enhanced computer tomography (CT) for abdominal lesions in a forensic context of suspicions death and to list the different radiological cadaveric modifications occurring normally at abdominal stage, which must be known by non forensic radiologists in case of any postmortem exam. Materials and methods: 30 cadavers have been submitted to a body CT-scan without injection of contrast material. CT exams were reviewed by two independent radiologists and radiological findings were compared with forensic autopsy data. Results: False positive CT findings included physiological postmortem transudates misdiagnosed with intra-abdominal bleedings, and putrefaction gas misdiagnosed with gas embolism, aeroporty, aerobily, digestive parietal pneumatosis. Incidentalomas without any role in death process were also reported. False negative CT findings included small contusions, vascular thromboses, acute infarcts foci, non radio-opaque foreign bodies. Normal cadaveric modifications were due to livor mortis and putrefaction, and are seen quickly (some hours) after death. Conclusion: The non forensic radiologist should be familiar with the normal abdominal postmortem features in order to avoid misdiagnoses, and detect informative lesions which can help and guide the forensic practitioner or the clinical physician.

  20. Furnace draft dynamics analysis after a flue gas desulphurization system incorporation

    Energy Technology Data Exchange (ETDEWEB)

    Zazo, J.F.L. [Tecnatom, S.A. (Spain)

    2007-07-01

    Due to environmental regulations some utilities are modifying coal-fired power groups by installing a flue gas desulfurisation system (FGDS) in order to remove SO{sub 2} from a gas stream. These studies have been ordered by 'Endesa Generacion' for the following power plant groups: C.T. Teruel Grs. 1-3, C.T. Litoral Gr. 2, C.T. Compostilla Gr. 3, C.T. Alucdia Grs. 1-2, C.T. Compostilla Grs. 4-5 (on-going); and C.T. Los Barrios (on-going). The pictures that appear in this abstract correspond to Compostilla Gr.4 and Los Barrios projects. In both cases FGDS installation implies a new booster fan and heat exchanger keeping former Induced Draft Fans (IDFs). The main goal for these projects is to analyze the new flue-gas dynamic, in order to: detect risk situations to equipment, particularly to boiler integrity, test control system strategies and interlocks, select parameters to valves and control system to minimize pressure transients, and test operation strategies. 14 figs.

  1. Communicating hydrocephalus. Cisternographic and neuropathologic studies

    International Nuclear Information System (INIS)

    Price, D.L.; James, E.; Sperber, E.; Strecker, E.P.

    1976-01-01

    Chronic communicating hydrocephalus was produced in adult dogs by injection of silastic into the subarachnoid space. Electron microscopy was used to verify the sequence of pathologic changes in the ventricular wall. The pathologic findings were correlated with cisternographic images and measurements of cerebrospinal fluid (CSF) pressure. Early in hydrocephalus, the CSF pressure was increased and cisternograms showed ventricular entry and clearing; the ependyma was stretched and fluid accumulated in subependymal regions. In animals with chronic hydrocephalus, the CSF pressure was normal and cisternograms disclosed radioactivity persisting in the ventricles. At this time the ependyma was severely damaged, the subependymal white matter showed enlargement of the extracellular space, and degenerative changes were present in axons and myelin sheaths

  2. Spontaneous pneumocephalus after commercial air travel complicated by meningitis.

    Science.gov (United States)

    Javan, Ramin; Duszak, Richard; Eisenberg, Alan D; Eggers, Frank M

    2011-12-01

    Pneumocephalus usually results from trauma, infection, neoplasm, or iatrogenic causes. Barotrauma-induced spontaneous pneumocephalus is extremely rare, usually seen in divers or occassionally with air travel. We report a case of a 61-yr-old female presenting with confusion, fever, and respiratory failure one day after developing sudden nausea, vomiting, and headache during descent on a commercial airliner. Pneumocephalus and meningitis were present on admission. Sinus computed tomography (CT) showed pansinusitis and a tiny bone defect in the posterior wall of the right sphenoid sinus, through which a cisternogram later showed free communication with the prepontine cistern. An orbital CT 2 yr earlier after a fall showed the bone defect, with no other areas of abnormality or fracture. After repair of defects by otolaryngology and appropriate antibiotics, she did well and was eventually discharged. Changes in aircraft cabin pressure likely resulted in rupture of dura and arachnoid layers beneath the pre-existing bony defect, predisposed by existing sinus disease. The pathophysiology, implications, and potential sources of spontaneous pneumocephalus, as well as risks of postcraniotomy and post-trauma air-travel, are discussed.

  3. A study on CT features of intrahepatic bile duct abscess

    International Nuclear Information System (INIS)

    Min Pengqiu; Li Peng; He Zhiyan; Chen Weixia; Liu Yan

    2001-01-01

    Objective: To evaluate CT features of intrahepatic bile duct abscess (IBDA) and its pathologic basis. Methods: The CT imaging data of 31 consecutive cases of intrahepatic bile duct abscess proved by surgery or clinical treatments from October 1989 to February 1999 were retrospectively studied. The causes included acute obstructive suppurative cholangitis and retrograde infection due to different etiologies. For all the cases, the CT manifestations of liver abscess, bile duct abnormalities, and their relationship were observed respectively. Results: Manifestations of liver abscess were revealed in all cases (31/31, 100%). The CT manifestations of bile duct abnormalities included signs of etiologies caused bile duct obstruction and other signs including cholangiectasis (29/31, 93.5%), the dilated bile ducts communicated with (5/31, 16.1%) or abut on (8/31, 25.8%) the abscesses, and gas collection in bile ducts (10/31, 32.2%). The signs showing the relationship between liver abscess and bile duct abnormalities were that the abscesses complied with the obstructive site and the dilated bile ducts (15/31, 48.4%), and the liver abscesses located in different (7/31, 22.6%) or same (4/31, 12.9%) liver lobes or segments with gas collection in the dilated bile ducts. Conclusion: The CT manifestations of IBDA included signs of liver abscess, abnormalities of bile ducts, and signs showing their relationship. CT scanning was helpful in making comprehensive and accurate diagnosis of IBDA

  4. CT diagnosis of abdominal abscess in children

    International Nuclear Information System (INIS)

    Li Xin; Yang Zhiyong

    1998-01-01

    Purpose: To evaluate CT in the diagnosis of abdominal abscess in children. Methods: Analysis of CT manifestations in 23 cases proved by operation and needle aspiration. Causes: acute appendicitis 13 cases, ascending colon perforation 1 case, Meckel diverticulitis 2 cases, cause obscured 7 cases. Bolus injection of contrast medium was given in 19 cases. Results: The CT value had no relationship to the course of disease and type of bacteria, amount of abscess had positive relevance relative with course of illness. Air-fluid level or scattered gas bubbles was seen in abscesses in 52%; little calcified plague was present in 22%. All cases presented nonhomogeneous thick wall enhancement after one week of illness. Conclusion: The characteristic CT features of intra-abdominal abscess were the presence of air and little calcified plague shadow; a large air-fluid level was indicative of fistula, while the absence of air in the abscess can not exclude fistula

  5. Abdomen after a Puestow procedure: postoperative CT appearance, complications, and potential pitfalls.

    Science.gov (United States)

    Freed, K S; Paulson, E K; Frederick, M G; Keogan, M T; Pappas, T N

    1997-06-01

    To evaluate the postoperative computed tomographic (CT) appearance, complications, and potential pitfalls after a Puestow procedure (lateral side-to-side pancreaticojejunostomy). Forty CT examinations were performed after the Puestow procedure in 20 patients. Images were retrospectively reviewed by three radiologists. The pancreaticojejunal anastomosis was identified at 30 examinations and was immediately anterior to the pancreatic body or tail. The anastomosis contained fluid or gas on 11 scans and oral contrast material on four scans. On 15 scans, the anastomosis appeared as collapsed bowel without gas, fluid, or oral contrast material. The Roux-en-Y loop was identified on 28 (70%) scans and contained fluid or gas on 16 scans and oral contrast material on six scans. The Roux-en-Y loop appeared as collapsed bowel on six scans. When the anastomosis or Roux-en-Y loop contained fluid and gas, the appearance mimicked that of a pancreatic or parapancreatic abscess. Peripancreatic stranding was present on 28 scans and was due to either ongoing pancreatitis or postoperative change. Complications included 15 transient fluid collections, three abscesses, four pseudocysts, one hematoma, and one small-bowel and Roux-en-Y obstruction. Knowledge of the anatomy after a Puestow procedure is essential for accurate interpretation of CT scans.

  6. HIGH-Resolution CT in Chronic Pulmonary Changes after Mustard Gas Exposure

    International Nuclear Information System (INIS)

    Bagheri, M.H.; Mostafavi, S.H.

    2003-01-01

    Purpose: To identify the findings of high-resolution CT (HRCT) of the lung in patients with previous sulfur mustard gas exposure, and to correlate these findings with clinical and chest X-ray (CXR) results. Material and Methods: 50 consecutive patients were studied prospectively. The clinical data were recorded. Standard p.a. CXR and HRCT of the lung and spirometry were performed. The findings of CXR, HRCT and clinical and spirometry results were scored between 0 and 3 according to the severity of the findings. Results: HRCT abnormality was detected in all 50 patients (100%), while CXR was abnormal in 40 patients (80%). The most common HRCT findings was airway abnormalities (bronchial wall thickening in 100% of cases). Other important findings were suggestive of interstitial lung disease (ILD) (80%), bronchiectasis (26%), and emphysema (24%). A statistically significant correlation was found between the severity of clinical presentation and that of the HCTR scores in patients with bronchiectasis, bronchitis and ILD (p< 0.05), but not with severity scores of HRCT in patients with emphysema. No significant correlation was found between severity scores of CXR findings. HRCT evidence of bronchial wall thickening and with a lower frequency ILD were present despite normal CXR in 20% of the patients. Conclusion: The results of this study suggest that bronchial wall thickening, ILD and emphysema are common chronic pulmonary sequelae of sulfur mustard injury. HRCT of the chest should be considered as the imaging modality of choice in chemical war injury

  7. HIGH-Resolution CT in Chronic Pulmonary Changes after Mustard Gas Exposure

    Energy Technology Data Exchange (ETDEWEB)

    Bagheri, M.H.; Mostafavi, S.H. [Shiraz Univ. of Medical Siences (Iran, Islamic Republic of). Dept. of Radiology; Hosseini, S.K. [Shiraz Univ. of Medical Siences (Iran, Islamic Republic of). Dept. of Internal Medicine; Alavi, S.A. [Medical Center for Chemical Warfare Victims Foundation, Shiraz (Iran, Islamic Republic of)

    2003-05-01

    Purpose: To identify the findings of high-resolution CT (HRCT) of the lung in patients with previous sulfur mustard gas exposure, and to correlate these findings with clinical and chest X-ray (CXR) results. Material and Methods: 50 consecutive patients were studied prospectively. The clinical data were recorded. Standard p.a. CXR and HRCT of the lung and spirometry were performed. The findings of CXR, HRCT and clinical and spirometry results were scored between 0 and 3 according to the severity of the findings. Results: HRCT abnormality was detected in all 50 patients (100%), while CXR was abnormal in 40 patients (80%). The most common HRCT findings was airway abnormalities (bronchial wall thickening in 100% of cases). Other important findings were suggestive of interstitial lung disease (ILD) (80%), bronchiectasis (26%), and emphysema (24%). A statistically significant correlation was found between the severity of clinical presentation and that of the HCTR scores in patients with bronchiectasis, bronchitis and ILD (p< 0.05), but not with severity scores of HRCT in patients with emphysema. No significant correlation was found between severity scores of CXR findings. HRCT evidence of bronchial wall thickening and with a lower frequency ILD were present despite normal CXR in 20% of the patients. Conclusion: The results of this study suggest that bronchial wall thickening, ILD and emphysema are common chronic pulmonary sequelae of sulfur mustard injury. HRCT of the chest should be considered as the imaging modality of choice in chemical war injury.

  8. Xe enhanced CT in the human newborn infant

    International Nuclear Information System (INIS)

    Fuse, Yozen; Nemoto, Yuko; Shimizu, Mitsumasa; Uga, Naoki; Tada, Hiroshi; Fujii, Toshi; Machida, Keiichi; Kikuchi, Hideo; Izumi, Shigemitsu.

    1990-01-01

    With a cranial computed tomography (CT) using stable xenon gas as a diffusible tracer, we measured regional cerebral blood flow (rCBF) in 6 newborn infants with a variety of neurological abnormalities. Gestational ages and birthweights were 35 to 43 weeks and 2436 to 3540 g, respectively. Four infants exhibited hypoxic-ischemic encephalopathy (HIE), one infant had subdural hemorrhage and the other one was the infant with hyponatremia. A baseline CT was done during denitrogenation by 100% oxygen breathing and then a mixture of 35% xenon and 65% oxygen was breathed for 6 minutes. Six scans were obtained during the inhalation period then the infant was returned to breathing 100% oxygen and additional 7 scans were taken. Four samples of arterial blood were collected every 2 minutes before and during inhalation of the xenon gas. A rCBF was calculated with the changes of Hounsfield units in brain tissue and arterial blood. Relatively high blood flows in the region of the basal nuclei as well as decreased flows in the occipital white matter were observed in the infants with HIE. In an infant with subdural hemorrhage, the blood flows were markedly reduced in the areas adjacent to the lesion, including the basal nuclei, and frontal white matter in the opposite hemisphere. Xenon-enhanced CT by inhaling low concentration of the xenon gas enables to measure rCBF in the human newborn infants without no obvious side effect. (author)

  9. Multi-Detector CT Findings of the Normal Appendix in Children: Evaluation of the Position, Diameter, and Presence or Absence of Intraluminal Gas

    Energy Technology Data Exchange (ETDEWEB)

    Park, Woon Ju; Kim, Jong Chul [Dept. of Radiology, Chungnam National University College of Medicine, Daejeon (Korea, Republic of)

    2011-08-15

    To assess the usefulness of multi-detector CT (MDCT) with multiplanar reformations (MPR) for the evaluation of the position, diameter and presence or absence of intraluminal gas in the normal appendix in children. From 2007 to 2010, we retrospectively analyzed the MDCT images of normal appendices in 133 children, and evaluated the position, diameter, and presence or absence of intraluminal gas in the appendix. Among the 133 appendices, type I (postileal and medial paracecal position) was found in 64 children, type II (subcecal position) in 22, type III (retrocecal and retrocolic/laterocolic position) in 15, type IV (preileal and medial colic position) in 16, and type V (lower pelvic position) in 16 children. The mean diameter was 5.8 mm {+-} 1.2 (SD) (range; 3.2-8.7 mm). There was a high correlation between the appendiceal diameter and age (p = 0.000).There was no statistically significant difference in the appendiceal diameter between boys and girls (p = 0.470). Intraluminal gas was found in 115 appendices and there was no statistically significant correlation between the appendiceal diameter and intraluminal gas (p = 0.502). The MDCT with MPR was useful for the evaluation of the normal appendices in children. The procedure may be useful for the diagnosis of equivocal or unusual appendicitis in children.

  10. Functional Imaging: CT and MRI

    OpenAIRE

    van Beek, Edwin JR; Hoffman, Eric A

    2008-01-01

    Numerous imaging techniques permit evaluation of regional pulmonary function. Contrast-enhanced CT methods now allow assessment of vasculature and lung perfusion. Techniques using spirometric controlled MDCT allow for quantification of presence and distribution of parenchymal and airway pathology, Xenon gas can be employed to assess regional ventilation of the lungs and rapid bolus injections of iodinated contrast agent can provide quantitative measure of regional parenchymal perfusion. Advan...

  11. Imaging and clinical significance of hepatic portal venous gas seen in adult patients

    International Nuclear Information System (INIS)

    Aikawa, Hisayuki; Mori, Hiromu; Miyake, Hidetoshi

    1994-01-01

    In 10 adult patients with hepatic portal venous gas (HPVG), the clinical significance of HPVG and the efficacy of X-ray computed tomography (CT) were evaluated. HPVC was associated with ischemic bowel disease (n=3), trauma (n=4), liver abscess (n=1), sepsis (n=1) and unknown etiology (n=1). The diagnostic ability of CT for the detection of HPVG was far superior to that of plain abnormal radiograph. Of 9 patients who underwent CT, HPVG located in the left hepatic lobe in all patients, and also in right hepatic lobe in 7 patients. Gas could be recognized in the left lobe and the anterior segment of the right lobe more clearly than in the posterior segment of the right lobe because of its larger amount of intravenous collection. The mortality rate of our cases was 100%. Gas was demonstrated simultaneously in the portal vein radicles and hepatic veins on CT in 4 patients with no clinical evidence of sepsis, which suggested the possibility of intraparenchymal shift of gas from the portal vein into the hepatic vein. In a single case with sepsis, gas was noted in various vessels, including arteries, in addition to the portal venous system. The authors conclude that HPVG is still a grave sign in Japan and prompt appropriate treatment is required. CT may be of great value in the early detection of HPVG and may indicate its etiology. (author)

  12. CT of pancreatitis

    International Nuclear Information System (INIS)

    Fukuda, Toshio

    1990-01-01

    One hundred and two cases of acute and chronic pancreatitis were studied by computed tomography. Fluid collection was detected by CT in 45 cases, and the common extrapancreatic sites of involvement included the lesser sac (13 cases), anterior pararenal space (9 cases), transverse mesocolon (7 cases) and posterior pararenal space (5 cases). Ten cases of spontaneous resolution of pancreatic pseudocysts were encountered. Cystojejunostomy was done on 6 patients. A 4-to-6-weeks time interval has been currently accepted as necessary for pseudocyst wall maturation. However, the surgery was not possible in two patients in this series since the cyst wall was too thin. It is considered that the time over 3 months is required for surgical anastomosis of the cyst to the gastrointestinal tract. Pancreatic abscess has become the most common cause of death from pancreatitis. In this series pancreatic abscess occurred in 8 patients. Gas collection in the pancreas was observed in only one patient. In the other patients, pseudocysts had become infected and converted to abscesses. The CT number of 4 infected pseudocysts was less than 15 HU. Thus, it was not possible to distinguish infected from noninfected pseudocysts by CT. The author studied 9 patients with focal inflammatory mass of the pancreas with histologically proved severe fibrosis. All masses were small. Angiography showed occlusion or marked stenosis of the splenic vein in 3 cases. The postcontract CT (after intravenous bolus injection) in 7 cases of focal inflammatory mass demonstrated almost equal enhanced effect of the mass as compared with the adjacent normal pancreatic parenchyma. This finding is considered to be useful in distinguishing inflammatory mass from pancreatic carcinoma. (author)

  13. Value of CT in the Discrimination of Fatal from Non-Fatal Stercoral Colitis

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Cheng Hsien; Huang, Chen Chin; Wang, Li Jen; Wong, Yon Cheng; Wang, Chao Jan; Lo, Wang Chak; Lin, Being Chuan; Wan, Yung Liang; Haueh, Chuen [Chang Gung Memorial Hospital, Chang Gung University, Taoyuan (China)

    2012-06-15

    Clinical presentation and physical signs may be unreliable in the diagnosis of stercoral colitis (SC). This study evaluates the value of computed tomography (CT) in distinguishing fatal from non-fatal SC. Ten patients diagnosed as SC were obtained from inter-specialist conferences. Additional 13 patients with suspected SC were identified via the Radiology Information System (RIS). These patients were divided into two groups; fatal and non-fatal SCs. Their CT images are reviewed by two board-certified radiologists blinded to the clinical data and radiographic reports. SC occurred in older patients and displayed no gender predisposition. There was significant correlation between fatal SC and CT findings of dense mucosa (p 0.017), perfusion defects (p = 0.026), ascites (p = 0.023), or abnormal gas (p = 0.033). The sensitivity, specificity, and accuracy of dense mucosa were 71%, 86%, and 81%, respectively. These figures were 75%, 79%, and 77% for perfusion defects; 75%, 80%, and 78% for ascites; and 50%, 93%, and 78% for abnormal gas, respectively. Each CT sign of mucosal sloughing and pericolonic abscess displayed high specificity of 100% and 93% for diagnosing fatal SC, respectively. However, this did not reach statistical significance in diagnosing fatal SC. CT appears to be valuable in discriminating fatal from non-fatal SC.

  14. Value of CT in the Discrimination of Fatal from Non-Fatal Stercoral Colitis

    International Nuclear Information System (INIS)

    Wu, Cheng Hsien; Huang, Chen Chin; Wang, Li Jen; Wong, Yon Cheng; Wang, Chao Jan; Lo, Wang Chak; Lin, Being Chuan; Wan, Yung Liang; Haueh, Chuen

    2012-01-01

    Clinical presentation and physical signs may be unreliable in the diagnosis of stercoral colitis (SC). This study evaluates the value of computed tomography (CT) in distinguishing fatal from non-fatal SC. Ten patients diagnosed as SC were obtained from inter-specialist conferences. Additional 13 patients with suspected SC were identified via the Radiology Information System (RIS). These patients were divided into two groups; fatal and non-fatal SCs. Their CT images are reviewed by two board-certified radiologists blinded to the clinical data and radiographic reports. SC occurred in older patients and displayed no gender predisposition. There was significant correlation between fatal SC and CT findings of dense mucosa (p 0.017), perfusion defects (p = 0.026), ascites (p = 0.023), or abnormal gas (p = 0.033). The sensitivity, specificity, and accuracy of dense mucosa were 71%, 86%, and 81%, respectively. These figures were 75%, 79%, and 77% for perfusion defects; 75%, 80%, and 78% for ascites; and 50%, 93%, and 78% for abnormal gas, respectively. Each CT sign of mucosal sloughing and pericolonic abscess displayed high specificity of 100% and 93% for diagnosing fatal SC, respectively. However, this did not reach statistical significance in diagnosing fatal SC. CT appears to be valuable in discriminating fatal from non-fatal SC.

  15. Detailed analysis of the density change on chest CT of COPD using non-rigid registration of inspiration/expiration CT scans

    International Nuclear Information System (INIS)

    Kim, Eun Young; Seo, Joon Beom; Lee, Hyun Joo; Kim, Namkug; Lee, Eunsol; Lee, Sang Min; Oh, Sang Young; Hwang, Hye Jeon; Oh, Yeon-Mok; Lee, Sang-Do

    2015-01-01

    One objective was to evaluate the air trapping index (ATI), measured by inspiration/expiration CT, in COPD patients and nonsmokers. Another objective was to assess the association between the pulmonary function test (PFT) and CT parameters such as ATI or other indices, separately in the whole lung, in emphysema, and in hyperinflated and normal lung areas. One hundred and thirty-eight COPD patients and 29 nonsmokers were included in our study. The ATI, the emphysema index (EI), the gas trapping index (Exp -856) and expiration/inspiration ratio of mean lung density (E/Iratio of MLD) were measured on CT. The values of the whole lung, of emphysema, and of hyperinflated and normal lung areas were compared and then correlated with various PFT parameters. Compared with nonsmokers, COPD patients showed a higher ATI in the whole lung and in each lung lesion (all P 25-75% , RV and RV/TLC, and was comparable to Exp -856 and the E/I ratio of MLD. The ATI of emphysema and hyperinflated areas on CT showed better correlation than the normal lung area with PFT parameters. Detailed analysis of density change at inspiration and expiration CT of COPD can provide new insights into pulmonary functional impairment in each lung area. (orig.)

  16. Comparison of CT numbers between cone-beam CT and multi-detector CT

    International Nuclear Information System (INIS)

    Kim, Dong Soo; Han, Won Jeong; Kim, Eun Kyung

    2010-01-01

    To compare the CT numbers on 3 cone-beam CT (CBCT) images with those on multi-detector CT (MDCT) image using CT phantom and to develop linear regressive equations using CT numbers to material density for all the CT scanner each. Mini CT phantom comprised of five 1 inch thick cylindrical models with 1.125 inches diameter of materials with different densities (polyethylene, polystyrene, plastic water, nylon and acrylic) was used. It was scanned in 3 CBCTs (i-CAT, Alphard VEGA, Implagraphy SC) and 1 MDCT (Somatom Emotion). The images were saved as DICOM format and CT numbers were measured using OnDemand 3D. CT numbers obtained from CBCTs and MDCT images were compared and linear regression analysis was performed for the density, ρ(g/cm 3 ), as the dependent variable in terms of the CT numbers obtained from CBCTs and MDCT images. CT numbers on i-CAT and Implagraphy CBCT images were smaller than those on Somatom Emotion MDCT image (p<0.05). Linear relationship on a range of materials used for this study were ρ=0.001 H+1.07 with R2 value of 0.999 for Somatom Emotion, ρ=0.002 H+1.09 with R2 value of 0.991 for Alphard VEGA, ρ=0.001 H+1.43 with R2 value of 0.980 for i-CAT and ρ=0.001 H+1.30 with R2 value of 0.975 for Implagraphy. CT numbers on i-CAT and Implagraphy CBCT images were not same as those on Somatom Emotion MDCT image. The linear regressive equations to determine the density from the CT numbers with very high correlation coefficient were obtained on three CBCT and MDCT scan.

  17. Comparison of CT numbers between cone-beam CT and multi-detector CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Soo; Han, Won Jeong; Kim, Eun Kyung [Department of Oral and Maxillofacial Radiology, School of Dentistry, Dankook University, Cheonan (Korea, Republic of)

    2010-06-15

    To compare the CT numbers on 3 cone-beam CT (CBCT) images with those on multi-detector CT (MDCT) image using CT phantom and to develop linear regressive equations using CT numbers to material density for all the CT scanner each. Mini CT phantom comprised of five 1 inch thick cylindrical models with 1.125 inches diameter of materials with different densities (polyethylene, polystyrene, plastic water, nylon and acrylic) was used. It was scanned in 3 CBCTs (i-CAT, Alphard VEGA, Implagraphy SC) and 1 MDCT (Somatom Emotion). The images were saved as DICOM format and CT numbers were measured using OnDemand 3D. CT numbers obtained from CBCTs and MDCT images were compared and linear regression analysis was performed for the density, {rho}(g/cm{sup 3}), as the dependent variable in terms of the CT numbers obtained from CBCTs and MDCT images. CT numbers on i-CAT and Implagraphy CBCT images were smaller than those on Somatom Emotion MDCT image (p<0.05). Linear relationship on a range of materials used for this study were {rho}=0.001 H+1.07 with R2 value of 0.999 for Somatom Emotion, {rho}=0.002 H+1.09 with R2 value of 0.991 for Alphard VEGA, {rho}=0.001 H+1.43 with R2 value of 0.980 for i-CAT and {rho}=0.001 H+1.30 with R2 value of 0.975 for Implagraphy. CT numbers on i-CAT and Implagraphy CBCT images were not same as those on Somatom Emotion MDCT image. The linear regressive equations to determine the density from the CT numbers with very high correlation coefficient were obtained on three CBCT and MDCT scan.

  18. WE-AB-202-06: Correlating Lung CT HU with Transformation-Based and Xe-CT Derived Ventilation

    International Nuclear Information System (INIS)

    Du, K; Patton, T; Bayouth, J; Reinhardt, J; Christensen, G

    2016-01-01

    Purpose: Regional lung ventilation is useful to reduce radiation-induced function damage during lung cancer radiation therapy. Recently a new direct HU (Hounsfield unit)-based method was proposed to estimate the ventilation potential without image registration. The purpose of this study is to examine if there is a functional dependence between HU values and transformation-based or Xe-CT derived ventilation. Methods: 4DCT images acquired from 13 patients prior to radiation therapy and 4 mechanically ventilated sheep subjects which also have associated Xe-CT images were used for this analysis. Transformation-based ventilation was computed using Jacobian determinant of the transformation field between peak-exhale and peak-inhale 4DCT images. Both transformation and Xe-CT derived ventilation was computed for each HU bin. Color scatter plot and cumulative histogram were used to compare and validate the direct HU-based method. Results: There was little change of the center and shape of the HU histograms between free breathing CT and 4DCT average, with or without smoothing, and between the repeated 4DCT scans. HU of −750 and −630 were found to have the greatest transformation-based ventilation for human and sheep subjects, respectively. Maximum Xe-CT derived ventilation was found to locate at HU of −600 in sheep subjects. The curve between Xe-CT ventilation and HU was noisy for tissue above HU −400, possibly due to less intensity change of Xe gas during wash-out and wash-in phases. Conclusion: Both transformation-based and Xe-CT ventilation demonstrated that lung tissues with HU values in the range of (-750, −600) HU have the maximum ventilation potential. The correlation between HU and ventilation suggests that HU might be used to help guide the ventilation calculation and make it more robust to noise and image registration errors. Research support from NIH grants CA166703 and CA166119 and a gift from Roger Koch.

  19. WE-AB-202-06: Correlating Lung CT HU with Transformation-Based and Xe-CT Derived Ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Du, K; Patton, T; Bayouth, J [University of Wisconsin, Madison, WI (United States); Reinhardt, J; Christensen, G [The University of Iowa, Iowa City, IA (United States)

    2016-06-15

    Purpose: Regional lung ventilation is useful to reduce radiation-induced function damage during lung cancer radiation therapy. Recently a new direct HU (Hounsfield unit)-based method was proposed to estimate the ventilation potential without image registration. The purpose of this study is to examine if there is a functional dependence between HU values and transformation-based or Xe-CT derived ventilation. Methods: 4DCT images acquired from 13 patients prior to radiation therapy and 4 mechanically ventilated sheep subjects which also have associated Xe-CT images were used for this analysis. Transformation-based ventilation was computed using Jacobian determinant of the transformation field between peak-exhale and peak-inhale 4DCT images. Both transformation and Xe-CT derived ventilation was computed for each HU bin. Color scatter plot and cumulative histogram were used to compare and validate the direct HU-based method. Results: There was little change of the center and shape of the HU histograms between free breathing CT and 4DCT average, with or without smoothing, and between the repeated 4DCT scans. HU of −750 and −630 were found to have the greatest transformation-based ventilation for human and sheep subjects, respectively. Maximum Xe-CT derived ventilation was found to locate at HU of −600 in sheep subjects. The curve between Xe-CT ventilation and HU was noisy for tissue above HU −400, possibly due to less intensity change of Xe gas during wash-out and wash-in phases. Conclusion: Both transformation-based and Xe-CT ventilation demonstrated that lung tissues with HU values in the range of (-750, −600) HU have the maximum ventilation potential. The correlation between HU and ventilation suggests that HU might be used to help guide the ventilation calculation and make it more robust to noise and image registration errors. Research support from NIH grants CA166703 and CA166119 and a gift from Roger Koch.

  20. WE-AB-202-07: Ventilation CT: Voxel-Level Comparison with Hyperpolarized Helium-3 & Xenon-129 MRI

    Energy Technology Data Exchange (ETDEWEB)

    Tahir, B; Marshall, H; Hughes, P; Stewart, N; Horn, F; Collier, G; Norquay, G; Hart, K; Swinscoe, J; Hatton, M; Wild, J; Ireland, R [University of Sheffield, Sheffield (United Kingdom)

    2016-06-15

    Purpose: To compare the spatial correlation of ventilation surrogates computed from inspiratory and expiratory breath-hold CT with hyperpolarized Helium-3 & Xenon-129 MRI in a cohort of lung cancer patients. Methods: 5 patients underwent expiration & inspiration breath-hold CT. Xenon-129 & {sup 1}H MRI were also acquired at the same inflation state as inspiratory CT. This was followed immediately by acquisition of Helium-3 & {sup 1}H MRI in the same breath and at the same inflation state as inspiratory CT. Expiration CT was deformably registered to inspiration CT for calculation of ventilation CT from voxel-wise differences in Hounsfield units. Inspiration CT and the Xenon-129’s corresponding anatomical {sup 1}H MRI were registered to Helium-3 MRI via the same-breath anatomical {sup 1}H MRI. This enabled direct comparison of CT ventilation with Helium-3 MRI & Xenon-129 MRI for the median values in corresponding regions of interest, ranging from finer to coarser in-plane dimensions of 10 by 10, 20 by 20, 30 by 30 and 40 by 40, located within the lungs as defined by the same-breath {sup 1}H MRI lung mask. Spearman coefficients were used to assess voxel-level correlation. Results: The median Spearman’s coefficients of ventilation CT with Helium-3 & Xenon-129 MRI for ROIs of 10 by 10, 20 by 20, 30 by 30 and 40 by 40 were 0.52, 0.56, 0.60 and 0.68 and 0.40, 0.42, 0.52 and 0.70, respectively. Conclusion: This work demonstrates a method of acquiring CT & hyperpolarized gas MRI (Helium-3 & Xenon-129 MRI) in similar breath-holds to enable direct spatial comparison of ventilation maps. Initial results show moderate correlation between ventilation CT & hyperpolarized gas MRI, improving for coarser regions which could be attributable to the inherent noise in CT intensity, non-ventilatory effects and registration errors at the voxel-level. Thus, it may be more beneficial to quantify ventilation at a more regional level.

  1. Detailed analysis of the density change on chest CT of COPD using non-rigid registration of inspiration/expiration CT scans

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Young [Chonbuk National University Medical School and Hospital, Research Institute of Clinical Medicine, Department of Radiology, Jeollabuk-do (Korea, Republic of); University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea, Republic of); Seo, Joon Beom; Lee, Hyun Joo; Kim, Namkug; Lee, Eunsol; Lee, Sang Min; Oh, Sang Young [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea, Republic of); Hwang, Hye Jeon [Hallym University Sacred Heart Hospital, Department of Radiology, Hallym University College of Medicine, Gyeonggi-do (Korea, Republic of); Oh, Yeon-Mok; Lee, Sang-Do [University of Ulsan College of Medicine, Asan Medical Center, Department of Pulmonary and Critical Care Medicine, and Clinical Research Center for Chronic Obstructive Airway Diseases, Seoul (Korea, Republic of)

    2014-09-14

    One objective was to evaluate the air trapping index (ATI), measured by inspiration/expiration CT, in COPD patients and nonsmokers. Another objective was to assess the association between the pulmonary function test (PFT) and CT parameters such as ATI or other indices, separately in the whole lung, in emphysema, and in hyperinflated and normal lung areas. One hundred and thirty-eight COPD patients and 29 nonsmokers were included in our study. The ATI, the emphysema index (EI), the gas trapping index (Exp -856) and expiration/inspiration ratio of mean lung density (E/Iratio of MLD) were measured on CT. The values of the whole lung, of emphysema, and of hyperinflated and normal lung areas were compared and then correlated with various PFT parameters. Compared with nonsmokers, COPD patients showed a higher ATI in the whole lung and in each lung lesion (all P < 0.05). The ATI showed a higher correlation than EI with FEF{sub 25-75%}, RV and RV/TLC, and was comparable to Exp -856 and the E/I ratio of MLD. The ATI of emphysema and hyperinflated areas on CT showed better correlation than the normal lung area with PFT parameters. Detailed analysis of density change at inspiration and expiration CT of COPD can provide new insights into pulmonary functional impairment in each lung area. (orig.)

  2. Oxygen transport properties estimation by DSMC-CT simulations

    Energy Technology Data Exchange (ETDEWEB)

    Bruno, Domenico [Istituto di Metodologie Inorganiche e dei Plasmi, Consiglio Nazionale delle Ricerche - Via G. Amendola, 122 - 70125 Bari (Italy); Frezzotti, Aldo; Ghiroldi, Gian Pietro [Dipartimento di Scienze e Tecnologie Aerospaziali, Politecnico di Milano - Via La Masa, 34 - 20156 Milano (Italy)

    2014-12-09

    Coupling DSMC simulations with classical trajectories calculations is emerging as a powerful tool to improve predictive capabilities of computational rarefied gas dynamics. The considerable increase of computational effort outlined in the early application of the method (Koura,1997) can be compensated by running simulations on massively parallel computers. In particular, GPU acceleration has been found quite effective in reducing computing time (Ferrigni,2012; Norman et al.,2013) of DSMC-CT simulations. The aim of the present work is to study rarefied Oxygen flows by modeling binary collisions through an accurate potential energy surface, obtained by molecular beams scattering (Aquilanti, et al.,1999). The accuracy of the method is assessed by calculating molecular Oxygen shear viscosity and heat conductivity following three different DSMC-CT simulation methods. In the first one, transport properties are obtained from DSMC-CT simulations of spontaneous fluctuation of an equilibrium state (Bruno et al, Phys. Fluids, 23, 093104, 2011). In the second method, the collision trajectory calculation is incorporated in a Monte Carlo integration procedure to evaluate the Taxman’s expressions for the transport properties of polyatomic gases (Taxman,1959). In the third, non-equilibrium zero and one-dimensional rarefied gas dynamic simulations are adopted and the transport properties are computed from the non-equilibrium fluxes of momentum and energy. The three methods provide close values of the transport properties, their estimated statistical error not exceeding 3%. The experimental values are slightly underestimated, the percentage deviation being, again, few percent.

  3. Clinical Application of colored three-dimensional CT (3D-CT) for brain tumors using helical scanning CT (HES-CT)

    International Nuclear Information System (INIS)

    Ogura, Yuko; Katada, Kazuhiro; Fujisawa, Kazuhisa; Imai, Fumihiro; Kawase, Tsukasa; Kamei, Yoshifumi; Kanno, Tetsuo; Takeshita, Gen; Koga, Sukehiko

    1995-01-01

    We applied colored three-dimensional CT (colored 3D-CT) images to distinguish brain tumors from the surrounding vascular and bony structures using a work station system and helical scanning CT (HES-CT). CT scanners with a slip-ring system were employed (TCT-900S and X vigor). A slice thickness of 2 mm and bed speed of 2 mm/s were used. The volume of contrast medium injected was 60 to 70 ml. Four to 8 colors were used for the tissue segmentation on the workstation system (xtension) using the data transferred from HES-CT. Tissue segmentation succeeded on the colored 3D-CT images in all 13 cases. The relationship between the tumors and the surrounding structures were easily recognized. The technique was useful to simulate operative fields, because deep structures could be visualized by cutting and drilling the colored 3D-CT volumetric data. On the basis of our findings, we suggest that colored 3D-CT images should be used as a supplementary aid for preoperative simulation. (author)

  4. Ultra-low dose CT attenuation correction for PET/CT

    International Nuclear Information System (INIS)

    Xia Ting; Kinahan, Paul E; Alessio, Adam M; De Man, Bruno; Manjeshwar, Ravindra; Asma, Evren

    2012-01-01

    A challenge for positron emission tomography/computed tomography (PET/CT) quantitation is patient respiratory motion, which can cause an underestimation of lesion activity uptake and an overestimation of lesion volume. Several respiratory motion correction methods benefit from longer duration CT scans that are phase matched with PET scans. However, even with the currently available, lowest dose CT techniques, extended duration cine CT scans impart a substantially high radiation dose. This study evaluates methods designed to reduce CT radiation dose in PET/CT scanning. We investigated selected combinations of dose reduced acquisition and noise suppression methods that take advantage of the reduced requirement of CT for PET attenuation correction (AC). These include reducing CT tube current, optimizing CT tube voltage, adding filtration, CT sinogram smoothing and clipping. We explored the impact of these methods on PET quantitation via simulations on different digital phantoms. CT tube current can be reduced much lower for AC than that in low dose CT protocols. Spectra that are higher energy and narrower are generally more dose efficient with respect to PET image quality. Sinogram smoothing could be used to compensate for the increased noise and artifacts at radiation dose reduced CT images, which allows for a further reduction of CT dose with no penalty for PET image quantitation. When CT is not used for diagnostic and anatomical localization purposes, we showed that ultra-low dose CT for PET/CT is feasible. The significant dose reduction strategies proposed here could enable respiratory motion compensation methods that require extended duration CT scans and reduce radiation exposure in general for all PET/CT imaging. (paper)

  5. Ultra-low dose CT attenuation correction for PET/CT

    Science.gov (United States)

    Xia, Ting; Alessio, Adam M.; De Man, Bruno; Manjeshwar, Ravindra; Asma, Evren; Kinahan, Paul E.

    2012-01-01

    A challenge for PET/CT quantitation is patient respiratory motion, which can cause an underestimation of lesion activity uptake and an overestimation of lesion volume. Several respiratory motion correction methods benefit from longer duration CT scans that are phase matched with PET scans. However, even with the currently-available, lowest dose CT techniques, extended duration CINE CT scans impart a substantially high radiation dose. This study evaluates methods designed to reduce CT radiation dose in PET/CT scanning. Methods We investigated selected combinations of dose reduced acquisition and noise suppression methods that take advantage of the reduced requirement of CT for PET attenuation correction (AC). These include reducing CT tube current, optimizing CT tube voltage, adding filtration, CT sinogram smoothing and clipping. We explored the impact of these methods on PET quantitation via simulations on different digital phantoms. Results CT tube current can be reduced much lower for AC than that in low dose CT protocols. Spectra that are higher energy and narrower are generally more dose efficient with respect to PET image quality. Sinogram smoothing could be used to compensate for the increased noise and artifacts at radiation dose reduced CT images, which allows for a further reduction of CT dose with no penalty for PET image quantitation. Conclusion When CT is not used for diagnostic and anatomical localization purposes, we showed that ultra-low dose CT for PET/CT is feasible. The significant dose reduction strategies proposed here could enable respiratory motion compensation methods that require extended duration CT scans and reduce radiation exposure in general for all PET/CT imaging. PMID:22156174

  6. The correlation between the rise of the tumor temperature during the hyperthermia treatment and the tumor blood flow measured by dynamic CT and 15O gas-positron emission tomography

    International Nuclear Information System (INIS)

    Hattori, Hideyuki

    1993-01-01

    This study was designed to determine the correlation between the rise of tumor temperature during hyperthermia treatment and the blood flow of the tumors measured by dynamic CT (DCT) and 15 O gas-positron emission tomography. In this report, we observed 20 patients with malignant tumors which underwent hyperthermia treatment. In each case, the temperature of the tumor was monitored with a photofiber sensor. DCT's and 15 O gas-positron emission tomographies were applied before the hyperthermia treatment. During the DCT, the tumor blood flow of each tumor was estimated by analyzing the time-dependent activity curve after a bolus injection. During the 15 O gas-positron emission tomography, the tumor blood flow was estimated by the C 15 O 2 -steady-state method. The value of the tumor blood flow estimated by DCT were proportional to those calculated by the 15 O gas-positron emission tomography. These values were inversely proportional to the rise of the temperature of the tumors during hyperthermia treatment. Our results imply that DCT as well as the 15 O gas-positron emission tomography can be used for the prediction of the tumor temperature rise during the hyperthermia treatment. (author)

  7. Clinical application of gated CT and dynamic CT

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, T; Oyama, Y; Ashida, H; Uji, T [Saint Marianna Univ., Kawasaki, Kanagawa (Japan). School of Medicine

    1980-03-01

    Gated CT and dynamic CT were outlined. Experiences of portal hypertension accompanied by venous mass in posterior mediastinum and the usefulness of dynamic CT for this disease were described. Gated CT of the heart could visualize intracardiac structures and morphological abnormalities by improving technique of post-data-aquisition correlation. Changes with time in CT images of normal kidneys were discussed on patients whose unilateral or bilateral kidneys were thought to be normal and who had received dynamic scan. Dynamic scan could visualize well blood circulation and mechanism of urine excretion in the kidney, which suggests a possibility of CT to detect not only morphological abnormalities but also functional disturbance of the kidney. The effectiveness of conventional CT study might be promoted in dynamic CT of the head.

  8. Anomalous effective dimensionality of quantum gas adsorption near nanopores.

    Science.gov (United States)

    Full, Steven J; McNutt, Jessica P; Cole, Milton W; Mbaye, Mamadou T; Gatica, Silvina M

    2010-08-25

    Three problems involving quasi-one-dimensional (1D) ideal gases are discussed. The simplest problem involves quantum particles localized within the 'groove', a quasi-1D region created by two adjacent, identical and parallel nanotubes. At low temperature (T), the transverse motion of the adsorbed gas, in the plane perpendicular to the axes of the tubes, is frozen out. Then, the low T heat capacity C(T) of N particles is that of a 1D classical gas: C(*)(T) = C(T)/(Nk(B)) --> 1/2. The dimensionless heat capacity C(*) increases when T ≥ 0.1T(x, y) (transverse excitation temperatures), asymptoting at C(*) = 2.5. The second problem involves a gas localized between two nearly parallel, co-planar nanotubes, with small divergence half-angle γ. In this case, too, the transverse motion does not contribute to C(T) at low T, leaving a problem of a gas of particles in a 1D harmonic potential (along the z axis, midway between the tubes). Setting ω(z) as the angular frequency of this motion, for T ≥ τ(z) ≡ ω(z)ħ/k(B), the behavior approaches that of a 2D classical gas, C(*) = 1; one might have expected instead C(*) = 1/2, as in the groove problem, since the limit γ ≡ 0 is 1D. For T τ(z)), motion is excited in the y direction, perpendicular to the plane of nanotubes, resulting in thermal behavior (C(*) = 7/4) corresponding to a gas in 7/2 dimensions, while at very high T (T > ħω(x)/k(B) ≡ τ(x) > τ(y)), the behavior becomes that of a D = 11/2 system. The third problem is that of a gas of particles, e.g. (4)He, confined in the interstitial region between four square parallel pores. The low T behavior found in this case is again surprising--that of a 5D gas.

  9. Underground Coal Gasification: Rates of Post Processing Gas Transport

    Czech Academy of Sciences Publication Activity Database

    Soukup, Karel; Hejtmánek, Vladimír; Stanczyk, K.; Šolcová, Olga

    2014-01-01

    Roč. 68, č. 12 (2014), s. 1707-1715 ISSN 0366-6352 R&D Projects: GA MŠk 7C12017 Grant - others:RFCS(XE) RFCR-CT-2011-00002 Institutional support: RVO:67985858 Keywords : underground coal gas ification * gas transport * textural properties Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 1.468, year: 2014

  10. The findings and the role of axial CT imaging and 3D imaging of gastric lesion by spiral CT

    International Nuclear Information System (INIS)

    Lee, Dong Ho; Ko, Young Tae

    1996-01-01

    The purpose of this study is to assess the efficacy of axial CT imaging and 3D imaging by spiral CT in the detection and evaluation of gastric lesion. Seventy-seven patients with pathologically-proven gastric lesions underwent axial CT and 3D imaging by spiral CT. There were 49 cases of advanced gastric carcinoma(AGC), 21 of early gastric carcinoma (EGC), three of benign ulcers, three of leiomyomas, and one case of lymphoma. Spiral CT was performed with 3-mm collimation, 4.5mm/sec table feed, and 1-1.5-mm reconstruction interval after the ingestion of gas. 3D imaging was obtained using the SSD technique, and on analysis a grade was given(excellent, good, poor). Axial CT scan was performed with 5-mm collimation, 7mm/sec table feed, and 5-mm reconstruction interval after the ingestion of water. Among 49 cases of AGC, excellent 3D images were obtained in seven patients (14.3%), good 3D images in 30(61.2%), and poor 3D images in 12(24.5%). Among the 12 patients with poor images, the cancers were located at the pyloric antrum in eight cases, were AGC Borrmann type 4 in three cases, and EGC-mimicking lesion in one case. Using axial CT scan alone, Borrmann's classification based tumor morphology were accurately identified in 67.3% of cases, but using 3D imaging, the corresponding figure was 85.7%. In 33 cases receiving surgery, good correlation between axial CT scan and pathology occurred in 72.7% of T class, and 69.7% of N class. Among 21 cases of EGC, excellent 3D images were obtained in three patients (14.3%), good 3D images in 14 (66.7%), and poor 3D images in two (9.5%). The other two cases of EGC were not detected. By axial CT scan, no tumor was detected in four cases, and there were two doubtful cases. 3D images of three benign ulcers were excellent in one case and good in two. 3D images of three leiomyomas and one lymphoma were excellent. Combined axial CT imaging and 3D imaging by spiral CT has the potential to accurately diagnose gastric lesions other than AGC

  11. Sacral-neuromodulation CT-guided

    International Nuclear Information System (INIS)

    Amoroso, Lamberto; Ricci, Stefano; Pelliccioni, Giuseppe; Scarpino, Osvaldo; Ghiselli, Roberto; Saba, Vittorio

    2005-01-01

    Purpose: Sacral neuromodulation is a new treatment for refractory voiding disorders such as urge incontinence, urinary retention, frequency-urgency syndromes and faecal incontinence. The current approach to sacral nerve stimulation consists of a two-stage procedure. The first is a PNE test (Percutaneous Nerve Evaluation) by a provisional electrically stimulated spinal needle, placed percutaneously in the S3 foramina for four of ten days. If successful, the second stage, permanent implantation, is carried out. The PNE test is performed under fluoroscopic control using the palpable bony sacral foramina as referral points. This technique can show some limitations, such as operator Rx exposure, poor visualization of sacral foramina because of bowel gas artefacts or sacral malformation. In order to reduce these inconveniences and to improve efficiency of the test we tried an alternative technique. The purpose of our study was to test the use of CT as an alternative technique in order to evaluate its advantages and possible routine use. Materials and methods: We tested 30 patients with the PNE test under CT guidance (16 males and 14 females) suffering from serious pelvic disorders and not responding to the normal therapeutic regime. Twenty-seven patient showed relative anatomical integrity of the pelvis and the sacrum, the remaining 3 patients presented morphological anormalities of the sacral foramina. With the patient in the prone position the sacral foramina were identified with CT volumetric scanning using a spiral CT scanner equipped with a second console for the three-dimensional reconstructions. Having identified the location of the S3 foramina, a sterile field was prepared and the spiral needle introduced checking correct positioning with a CT control scan. An electrode was inserted after having checked correct muscular contractile response and the precise position with a further CT scan. Results: Thirty patients were subjected to PNE under CT guidance for a

  12. Incidental physiological sliding hiatal hernia: a single center comparison study between CT with water enema and CT colonography.

    Science.gov (United States)

    Revelli, Matteo; Furnari, Manuele; Bacigalupo, Lorenzo; Paparo, Francesco; Astengo, Davide; Savarino, Edoardo; Rollandi, Gian Andrea

    2015-08-01

    Hiatal hernia is a well-known factor impacting on most mechanisms underlying gastroesophageal reflux, related with the risk of developing complications such as erosive esophagitis, Barrett's esophagus and ultimately, esophageal adenocarcinoma. It is our firm opinion that an erroneous reporting of hiatal hernia in CT exams performed with colonic distention may trigger a consecutive diagnostic process that is not only unnecessary, inducing a unmotivated anxiety in the patient, but also expensive and time-consuming for both the patient and the healthcare system. The purposes of our study were to determine whether colonic distention at CT with water enema and CT colonography can induce small sliding hiatal hernias and to detect whether hiatal hernias size modifications could be considered significant for both water and gas distention techniques. We retrospectively evaluated 400 consecutive patients, 200 undergoing CT-WE and 200 undergoing CTC, including 59 subjects who also underwent a routine abdominal CT evaluation on a different time, used as internal control, while a separate group of 200 consecutive patients who underwent abdominal CT evaluation was used as external control. Two abdominal radiologists assessed the CT exams for the presence of a sliding hiatal hernia, grading the size as small, moderate, or large; the internal control groups were directly compared with the corresponding CT-WE or CTC study looking for a change in hernia size. We used the Student's t test applying a size-specific correction factor, in order to account for the effect of colonic distention: these "corrected" values were then individually compared with the external control group. A sliding hiatal hernia was present in 51 % (102/200) of the CT-WE patients and in 48.5 % (97/200) of the CTC patients. Internal control CT of the 31 patients with a hernia at CT-WE showed resolution of the hernia in 58.1 % (18/31) of patients, including 76.5 % (13/17) and 45.5 % (5/11) of small and moderate

  13. CT-derived Biomechanical Metrics Improve Agreement Between Spirometry and Emphysema

    Science.gov (United States)

    Bhatt, Surya P.; Bodduluri, Sandeep; Newell, John D.; Hoffman, Eric A.; Sieren, Jessica C.; Han, Meilan K.; Dransfield, Mark T.; Reinhardt, Joseph M.

    2016-01-01

    Rationale and Objectives Many COPD patients have marked discordance between FEV1 and degree of emphysema on CT. Biomechanical differences between these patients have not been studied. We aimed to identify reasons for the discordance between CT and spirometry in some patients with COPD. Materials and Methods Subjects with GOLD stage I–IV from a large multicenter study (COPDGene) were arranged by percentiles of %predicted FEV1 and emphysema on CT. Three categories were created using differences in percentiles: Catspir with predominant airflow obstruction/minimal emphysema, CatCT with predominant emphysema/minimal airflow obstruction, and Catmatched with matched FEV1 and emphysema. Image registration was used to derive Jacobian determinants, a measure of lung elasticity, anisotropy and strain tensors, to assess biomechanical differences between groups. Regression models were created with the above categories as outcome variable, adjusting for demographics, scanner type, quantitative CT-derived emphysema, gas trapping, and airway thickness (Model 1), and after adding biomechanical CT metrics (Model 2). Results Jacobian determinants, anisotropy and strain tensors were strongly associated with FEV1. With Catmatched as control, Model 2 predicted Catspir and CatCT better than Model 1 (Akaike Information Criterion, AIC 255.8 vs. 320.8). In addition to demographics, the strongest independent predictors of FEV1 were Jacobian mean (β= 1.60,95%CI = 1.16 to 1.98; p<0.001), coefficient of variation (CV) of Jacobian (β= 1.45,95%CI = 0.86 to 2.03; p<0.001) and CV strain (β= 1.82,95%CI = 0.68 to 2.95; p = 0.001). CVs of Jacobian and strain are both potential markers of biomechanical lung heterogeneity. Conclusions CT-derived measures of lung mechanics improve the link between quantitative CT and spirometry, offering the potential for new insights into the linkage between regional parenchymal destruction and global decrement in lung function in COPD patients. PMID:27055745

  14. Focal airtrapping at expiratory high-resolution CT: comparison with pulmonary function tests

    International Nuclear Information System (INIS)

    Kauczor, H.U.; Hast, J.; Heussel, C.P.; Mildenberger, P.; Thelen, M.; Schlegel, J.

    2000-01-01

    This study was undertaken to determine prevalence, extent, and severity of focal airtrapping at expiratory high-resolution CT, and to compare focal airtrapping with age, gender, pulmonary function tests, and blood gas analysis. Two-hundred seventeen patients with and without pulmonary disease underwent paired inspiratory/expiratory high-resolution CT. Six scan pairs with corresponding scan levels were visually assessed for focal - not diffuse - airtrapping using a four-point scale. Pulmonary function tests and blood gas analysis were available for correlation in all patients (mean interval 5 days). Focal airtrapping with lower lung predominance was observed in 80 % of patients. Twenty-six of 26 patients with restrictive lung function impairment exhibited focal airtrapping (mean score 2.4), whereas only 72 of 98 (74 %) patients with obstruction did (mean score 1.5; p < 0.05). Fifty-eight of 70 (83 %) patients with normal lung function (mean score 1.8) and 19 of 23 (83 %) patients with mixed impairment (mean score 1.8) had focal airtrapping. Focal airtrapping showed negative correlations with static lung volumes (-0.27 to -0.37; p < 0.001) in all patients and moderate positive correlations with dynamic parameters (0.3-0.4; p < 0.001) in patients with obstruction. No significant correlations were found with age, gender, and blood gas analysis. Visual assessment of focal - not diffuse - airtrapping at expiratory high-resolution CT does not correlate with physiological evidence of obstruction as derived from pulmonary function tests since the perception of focal airtrapping requires an adequate expiratory increase in lung density. (orig.)

  15. Clinical comparison of radionuclide cisternography and computed tomography in CSF circulatory disturbance

    International Nuclear Information System (INIS)

    Tanabe, Masaya; Futatsuki, Minoru; Tanaka, Hiroshi.

    1980-01-01

    Forty-three patients with abnormal cisternograms were classified into (1) NPH, (2) Postmeningitic hydrocephalus, (3) Posttraumatic hydrocephalus, (4) Postoperative hydrocephalus (tumor) (5) Postoperative hydrocephalus (vascular disease), (6) Meningitis, (7) Tumor, (8) Vascular disease, (9) Degenerative disease and (10) Miscellaneous. Cisternography was done by a scinticamera with 111 In-DTPA and all groups were scanned by IInd generation CT scanner. The result of the cisternography was not always compatible with the CT findings. We found a case of anatomically normal but functionally abnormal cisterns and ventricular system. In all classified disorder groups, the cisternography detected functioning cisterns in CSF dynamics but the CT visualized anatomically open cisterns. By the combined use of these two examinations, a local cisternal block was detected. Ten in 20 cases with operated (V-P shunt) hydrocephalus clinically improved. But the result of these techniques, failed to assess the effectiveness of the V-P shunt. V-P shunt was effective in 8 out of 14 cases with persistent ventricular reflux and delayed clearance, and in 9 out of 17 cases with total ventricular dilatation. We concluded that the combined use of the RI cisternography and the computed tomography was better than single examination to detect CSF circulatory disturbance but we were not satisfied with the joint use in the evaluation of the effect of V-P shunt. No adverse reaction was experienced in the 43 patients with 111 In-DTPA. (author)

  16. Clinical comparison of radionuclide cisternography and computed tomography in CSF circulatory disturbance

    Energy Technology Data Exchange (ETDEWEB)

    Tanabe, M.; Futatsuki, M. (Tazuke Kofukai Medical Research Inst., Osaka (Japan). Kitano Hospital); Tanaka, H.

    1980-12-01

    Forty-three patients with abnormal cisternograms were classified into (1) NPH, (2) Postmeningitic hydrocephalus, (3) Posttraumatic hydrocephalus, (4) Postoperative hydrocephalus (tumor) (5) Postoperative hydrocephalus (vascular disease), (6) Meningitis, (7) Tumor, (8) Vascular disease, (9) Degenerative disease and (10) Miscellaneous. Cisternography was done by a scinticamera with /sup 111/In-DTPA and all groups were scanned by IInd generation CT scanner. The result of the cisternography was not always compatible with the CT findings. We found a case of anatomically normal but functionally abnormal cisterns and ventricular system. In all classified disorder groups, the cisternography detected functioning cisterns in CSF dynamics but the CT visualized anatomically open cisterns. By the combined use of these two examinations, a local cisternal block was detected. Ten in 20 cases with operated (V-P shunt) hydrocephalus clinically improved. But the result of these techniques, failed to assess the effectiveness of the V-P shunt. V-P shunt was effective in 8 out of 14 cases with persistent ventricular reflux and delayed clearance, and in 9 out of 17 cases with total ventricular dilatation. We concluded that the combined use of the RI cisternography and the computed tomography was better than single examination to detect CSF circulatory disturbance but we were not satisfied with the joint use in the evaluation of the effect of V-P shunt. No adverse reaction was experienced in the 43 patients with /sup 111/In-DTPA.

  17. Experimental investigations on a common centrifugal pump operating under gas entrainment conditions

    Energy Technology Data Exchange (ETDEWEB)

    Schäfer, Thomas, E-mail: thomas.schaefer@hzdr.de [Helmholtz-Zentrum Dresden-Rossendorf, Institute of Fluid Dynamics (Germany); Neumann, Martin [Technische Universität Dresden, AREVA Endowed Chair of Imaging Techniques in Energy and Process Engineering (Germany); Bieberle, André [Helmholtz-Zentrum Dresden-Rossendorf, Institute of Fluid Dynamics (Germany); Hampel, Uwe [Helmholtz-Zentrum Dresden-Rossendorf, Institute of Fluid Dynamics (Germany); Technische Universität Dresden, AREVA Endowed Chair of Imaging Techniques in Energy and Process Engineering (Germany)

    2017-05-15

    Highlights: • The pump performance has been evaluated for several gas entrainment conditions. • The gas entraining flow regime has a large impact on the pump performance. • High-resolution gamma-ray computed tomography (HireCT) has been applied. • Gas holdup inside the operating impeller has been visualized and quantified. • Gas holdup profiles along selected streamlines have been calculated. - Abstract: This paper presents an experimental study on the effects of additional gas entrainment in centrifugal pumps designed for conveying liquid phases only. The pump performance has been evaluated for several gas entrainment conditions, and for various operational settings of the pump, such as its alignment and the rotational speed of the impeller. As a main performance indicator the impact of entrained gas on the hydraulic power of the pump has been analyzed using experimental data. Additionally, high-resolution gamma-ray computed tomography (HireCT) operated in time-averaged rotation-synchronized scanning mode has been applied to quantify local phase fraction distributions inside the rapidly rotating pump impeller. Based on these quantitative tomographic measurements, gas holdup profiles along selected streamlines have been calculated and gas accumulation areas inside the impeller chambers have been visualized. Thus, various internally accumulated gas holdup patterns have been identified and, eventually, associated with characteristic pump performance behaviors. Moreover, the tomographic measuring method allowed an enhanced gas holdup analysis in specified pump compartments. As a result, the related specific gas and liquid phase holdup profiles have been evaluated.

  18. Experimental investigations on a common centrifugal pump operating under gas entrainment conditions

    International Nuclear Information System (INIS)

    Schäfer, Thomas; Neumann, Martin; Bieberle, André; Hampel, Uwe

    2017-01-01

    Highlights: • The pump performance has been evaluated for several gas entrainment conditions. • The gas entraining flow regime has a large impact on the pump performance. • High-resolution gamma-ray computed tomography (HireCT) has been applied. • Gas holdup inside the operating impeller has been visualized and quantified. • Gas holdup profiles along selected streamlines have been calculated. - Abstract: This paper presents an experimental study on the effects of additional gas entrainment in centrifugal pumps designed for conveying liquid phases only. The pump performance has been evaluated for several gas entrainment conditions, and for various operational settings of the pump, such as its alignment and the rotational speed of the impeller. As a main performance indicator the impact of entrained gas on the hydraulic power of the pump has been analyzed using experimental data. Additionally, high-resolution gamma-ray computed tomography (HireCT) operated in time-averaged rotation-synchronized scanning mode has been applied to quantify local phase fraction distributions inside the rapidly rotating pump impeller. Based on these quantitative tomographic measurements, gas holdup profiles along selected streamlines have been calculated and gas accumulation areas inside the impeller chambers have been visualized. Thus, various internally accumulated gas holdup patterns have been identified and, eventually, associated with characteristic pump performance behaviors. Moreover, the tomographic measuring method allowed an enhanced gas holdup analysis in specified pump compartments. As a result, the related specific gas and liquid phase holdup profiles have been evaluated.

  19. Relevance of postmortem radiology to the diagnosis of fatal cerebral gas embolism from compressed air diving.

    Science.gov (United States)

    Cole, A J; Griffiths, D; Lavender, S; Summers, P; Rich, K

    2006-05-01

    To test the hypothesis that artefact caused by postmortem off-gassing is at least partly responsible for the presence of gas within the vascular system and tissues of the cadaver following death associated with compressed air diving. Controlled experiment sacrificing sheep after a period of simulated diving in a hyperbaric chamber and carrying out sequential postmortem computed tomography (CT) on the cadavers. All the subject sheep developed significant quantities of gas in the vascular system within 24 hours, as demonstrated by CT and necropsy, while the control animals did not. The presence of gas in the vascular system of human cadavers following diving associated fatalities is to be expected, and is not necessarily connected with gas embolism following pulmonary barotrauma, as has previously been claimed.

  20. PET/CT in lymphoma patients; PET-CT bei Lymphompatienten

    Energy Technology Data Exchange (ETDEWEB)

    Steinert, H.C. [Universitaetsspital Zuerich, Klinik und Poliklinik fuer Nuklearmedizin (Switzerland)

    2004-11-01

    First results of PET/CT in Hodgkin's disease (HD) and aggressive non-Hodgkin's lymphoma (NHL) are reported. From March 2001 to August 2004 822 PET/CT were performed at our clinic in lymphoma patients for primary staging, restaging after therapy, and diagnosis of recurrence. For coregistration non contrast-enhanced low-dose CT were used. Due to the exact anatomic localization of {sup 18}F-FDG accumulating lesions equivocal or false positive PET findings are avoided. In comparison to contrast enhanced CT, PET/CT has a higher sensitivity and specificity in patients with HD and aggressive NHL. Integration of PET/CT in treatment planning of radiation therapy optimizes the field volume. Even in the initial phase of clinical evaluation, PET/CT has proven useful in staging and restaging of lymphoma. The exact anatomic localization of the PET findings is essential for a precise report, for treatment planning of radiation therapy, and for planning surgical biopsy. (orig.) [German] Erste Ergebnisse der PET-CT bei Morbus Hodgkin (HD) und den aggressiven Non-Hodgkin-Lymphomen (NHL) werden beschrieben. Von Maerz 2001 bis August 2004 wurden 822 PET-CT bei Lymphompatienten zum primaeren Staging, zum Restaging nach Therapie und zur Rezidivdiagnostik an unserer Klinik durchgefuehrt. Fuer die Koregistration wurde ein Low-dose-CT ohne i.v.-Kontrastmittel verwendet. Durch die exakte anatomische Zuordnung der {sup 18}F-FDG aufnehmenden Laesionen wurden unklare oder falsch-positive PET-Befunde vermieden. Die PET-CT erzielte im Vergleich zur KM-verstaerkten CT eine hoehere Sensitivitaet und Spezifitaet bei Patienten mit HD und aggressiven NHL. Die Integration der PET-CT in die Planung der Strahlentherapie fuehrte zu einer Optimierung der Feldgrenzen. Die PET-CT hat sich bereits in der Phase der initialen klinischen Evaluation als wertvoll beim Staging und Restaging von Lymphomen erwiesen. Die exakte anatomische Zuordnung der PET-Informationen ist fuer eine sichere Befundung

  1. Patient dose simulation in X-ray CT using a radiation treatment-planning system

    International Nuclear Information System (INIS)

    Nakae, Yasuo; Oda, Masahiko; Minamoto, Takahiro

    2003-01-01

    Medical irradiation dosage has been increasing with the development of new radiological equipment and new techniques like interventional radiology. It is fair to say that patient dose has been increased as a result of the development of multi-slice CT. A number of studies on the irradiation dose of CT have been reported, and the computed tomography dose index (CTDI) is now used as a general means of determining CT dose. However, patient dose distribution in the body varies with the patient's constitution, bowel gas in the body, and conditions of exposure. In this study, patient dose was analyzed from the viewpoint of dose distribution, using a radiation treatment-planning computer. Percent depth dose (PDD) and the off-center ratio (OCR) of the CT beam are needed to calculate dose distribution by the planning computer. Therefore, X-ray CT data were measured with various apparatuses, and beam data were sent to the planning computer. Measurement and simulation doses in the elliptical phantom (Mix-Dp: water equivalent material) were collated, and the CT irradiation dose was determined for patient dose simulation. The rotational radiation treatment technique was used to obtain the patient dose distribution of CT, and patient dose was evaluated through simulation of the dose distribution. CT images of the thorax were sent to the planning computer and simulated. The result was that the patient dose distribution of the thorax was obtained for CT examination. (author)

  2. CT of hepatocellular carcinoma. Analysis of contrast-enhanced CT using CT arteriography

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, H; Tanaka, T; Hori, S; Tokunaga, K; Yoshioka, H [Osaka Univ. (Japan). Faculty of Medicine

    1981-02-01

    Although changes in the CT appearance resulting from contrast enhancement (CE) for hepatocellular carcinoma have been considered in association with vascularity of tumors, no detailed studies have yet been made. We analyzed changes in the CT appearance following CE by comparing with hepatic arteriogram and CT arteriogram (CTA) performed during intraarterial infusion of contrast medium. When tumors showing low density in the plain CT were enhanced by contrast, the results were variable, ranging from intensification of the low density to replacement by high density, and the results were classified into L/sub 0/ to L/sub 3/ according to vascularity of tumors. The results after CE could also be classified into I/sub 0/ to I/sub 3/ when tumors showed isodensity in the plain CT. There was a correlation between vascularity presumed from CE and vascularity by CTA. It may be concluded that tumor vascularity could be estimated by the findings of CE which might indicate a possibility of qualitative diagnosis of tumors.

  3. Intraosseous pneumatocyst of the ilium: CT findings in two cases and literature review

    International Nuclear Information System (INIS)

    Catalano, O.; De Rosa, F.; Muto, M.

    1997-01-01

    Intraosseous pneumatocyst of the ilium is a rare lesion of uncertain origin. It predilects male subjects and may be associated or not with sacroiliac joint degenerative disease, intra-articular gas, sacral pneumatocyst, and communication with the articular space. To our knowledge, only 16 observations have been reported in the literature. We have evaluated with plain radiographs and CT two additional cases. Plain films frequently identify these lesions, but CT is the method of choice in demonstrating their air density and assessing the possible abnormalities of the surrounding bone and sacroiliac joints. (orig.)

  4. X-ray CT imaging and image-based modelling study of gas exchange in the rice rhizosphere

    Science.gov (United States)

    Affholder, Marie-Cecile; Keyes, Samuel David; Roose, Tiina; Heppell, James; Kirk, Guy

    2016-04-01

    We used X-ray computer tomography and image-based modelling to investigate CO2 uptake by rice roots growing in submerged soil, and its consequences for the chemistry and biology of the rhizosphere. From previous work, three processes are known to greatly modify the rhizophere of rice and other wetland plants: (1) oxygenation of the submerged, anoxic soil by O2 transported through the root gas channels (aerenchyma); (2) oxidation of ferrous iron and resulting accumulation of ferric oxide; and (3) pH changes due to protons formed in iron oxidation and released from the roots to balance excess intake of cations over anions. A further process, so far not much investigated, is the possibility of CO2 uptake by the roots. Large amounts of CO2 accumulate in submerged soils because CO2 formed in soil respiration escapes only slowly by diffusion through the water-saturated soil pores. There is therefore a large CO2 gradient between the soil and the aerenchyma inside the root, and CO2 may be taken up by the roots and vented to the atmosphere. The extent of this and its consequences for rhizosphere chemistry and biology are poorly understood. We grew rice plants in a submerged, strongly-reduced, Philippine rice soil contained in 10-cm diameter, 20-cm deep Perspex pots. Four-week old rice seedlings, grown in nutrient culture, were transplanted into the pots at either 1 or 4 plants per pot, planted closely together. After 3 and 4 weeks, the pots were analysed with an X-ray CT scanner (Custom Nikon/Xtek Hutch; 80 mm by 56 mm field of view and 40 μm voxel size). Gas bubbles were extracted from the data by 3D median filtering and roots using a region-growth method. The images showed prominent and abundant gas bubbles in the soil bulk, but no or very few bubbles in the soil close to roots. There was a clear relation between the absence of gas bubbles and the presence of roots, as well as an increasing concentration of bubbles with depth through the soil. Analysis of the bubbles

  5. Absorbed dose in CT. Comparison by CT dose index

    International Nuclear Information System (INIS)

    Yamamoto, Kenji; Akazawa, Hiroshi; Andou, Takashi

    2002-01-01

    Few reports have discussed the absorbed dose on CT units with increased scanning capacity even with the current widespread adoption of multi-slice CT units. To compare and investigate the dose indexes among CT units, we measured the absorbed dose on CT units operating in Nagano Prefecture Japan. The measurements showed proportionality between phantom absorbed dose and the exposured mAs values in conventional scanning operation. Further, the measurements showed that the absorbed dose in the center of the phantom differed by about 2.1-fold between the highest and lowest levels on individual CT units. Within a single company, multi-slice CT units of the same company gave absorbed doses of about 1.3 to 1.5 times those of conventional single-slice CT units under the same exposured conditions of conventional scanning. When the scanning pitch was reduced in helical scanning, the absorbed dose at the center of the phantom increased. (author)

  6. X-ray and CT diagnosis of intraosseous ganglion

    International Nuclear Information System (INIS)

    Gong Xiangyang; Zhang Weimin; Yan Shigui

    2002-01-01

    Objective: To investigate the pathogenesis, clinical manifestations, imaging features, and differential diagnosis of intraosseous ganglion. Methods: Clinical and imaging features of 15 cases (5 men, 10 women; mean age 39.7 years) with intraosseous ganglia were retrospectively analyzed. There were 17 lesions, including 6 acetabular, 4 lunate, 3 proximal ends of tibia, 1 major tuberculum of humeral, 1 femoral head, 1 scaphoid, and 1 phalange. Results: ( 1 ) Common radiological features included a unilocular or multilocular cyst surrounded by a full and thin rim of sclerotic: bone in the subchondral epiphysis without any signs of degenerative joint disease. (2) Lesions were displayed as well-defined round radiolucent defect or multi-cystic changes with surrounding bony sclerosis or cystic and expansile change with irregular shape on CT scans. (3) CT showed an intraosseous ganglion communicating with adjacent joint in 1 patient. (4) CT values of the lesions were between 15 - 80 HU. (5) Gas in the cyst could be seen in 3 cases. Conclusion: Combined with patient's age, lesion distribution, clinical manifestations, and imaging features, it is possible to make a correct diagnosis of intraosseous ganglion

  7. Imaging of head and neck tumors -- methods: CT, spiral-CT, multislice-spiral-CT

    International Nuclear Information System (INIS)

    Baum, Ulrich; Greess, Holger; Lell, Michael; Noemayr, Anton; Lenz, Martin

    2000-01-01

    Spiral-CT is standard for imaging neck tumors. In correspondence with other groups we routinely use spiral-CT with thin slices (3 mm), a pitch of 1.3-1.5 and an overlapping reconstruction increment (2-3 mm). In patients with dental fillings a short additional spiral parallel to the corpus of the mandible reduces artifacts behind the dental arches and improves the diagnostic value of CT. For the assessment of the base of the skull, the orbital floor, the palate and paranasal sinuses an additional examination in the coronal plane is helpful. Secondary coronal reconstructions of axial scans are helpful in the evaluation of the crossing of the midline by small tumors of the tongue base or palate. For an optimal vascular or tissue contrast a sufficient volume of contrast medium and a start delay greater than 70-80 s are necessary. In our opinion the best results can be achieved with a volume of 150 ml, a flow of 2.5 ml/s and a start delay of 80 s. Dynamic enhanced CT is only necessary in some special cases. There is clear indication for dynamic enhanced CT where a glomus tumor is suspected. Additional functional CT imaging during i-phonation and/or Valsalva's maneuver are of great importance to prove vocal cords mobility. Therefore, imaging during i-phonation is an elemental part of every thorough examination of the hypopharynx and larynx region. Multislice-spiral-CT allows almost isotropic imaging of the head and neck region and improves the assessment of tumor spread and lymph node metastases in arbitrary oblique planes. Thin structures (the base of the skull, the orbital floor, the hard palate) as well as the floor of the mouth can be evaluated sufficiently with multiplanar reformations. Usually, additional coronal scanning is not necessary with multislice-spiral-CT. Multislice-spiral-CT is especially advantageous in defining the critical relationships of tumor and lymph node metastases and for functional imaging of the hypopharynx and larynx not only in the

  8. CT of portal vein tumor thrombosis. Usefulness of dynamic CT

    Energy Technology Data Exchange (ETDEWEB)

    Takemoto, Kazumasa; Inoue, Yuichi; Tanaka, Masahiro; Nemoto, Yutaka; Nakamura, Kenji [Osaka City Univ. (Japan). Faculty of Medicine

    1983-08-01

    We evaluated CT findings of portal vein tumor thrombosis in 16 hepatomas by plain, contrast and dynamic CT. Plain and contrast CT findings were an enlargement of the portal vein (81%), intraluminal low density area (63%). Dynamic CT enhanced the diagnostic capability of the tumor thrombus as a relatively low density area because of the marked enhancement of the portal vein. In addition, dynamic CT newly demonstrated hyperdense peripheral ring (35%) and arterio portal shunt (35%). It is advisable to select the scan level to include the portal vein when dynamic CT is performed in the patient of hepatocellular carcinoma.

  9. Multi-slice CT features of annular pancreas in neonates

    International Nuclear Information System (INIS)

    He Mingqing; Zhu Youzhi; Hu Kefei; Yin Chuangao; Hu Jun; Wang Song; Li Xu; Lu Zhongbin; Wang Yue; Liu Xiang

    2013-01-01

    Objective: To investigate the MSCT manifestations and their values in the diagnosis of annular pancreas in neonates. Methods: Retrospective analysis of clinical and CT findings in 27 cases with surgery-proved annular pancreas in neonates was made. The unenhanced and contrast-enhanced CT images were obtained in 20 patients. Two experienced radiologists determined the site and degree of obstruction, the relationship between the head of the pancreas and the obstruction point, and the surrounding tissue structure. Results: The direct signs included the fluid-filled or gas-filled bowel in the head of pancreas in 4 cases, the enhancement of surrounding soft tissue as enhanced pancreas in 17 cases, disappearance of the fat gap between the intestinal wall and the annular pancreas in 17 cases. The indirect signs included intestinal obstruction in 20 cases, 'single-bubble sign' in 2 cases, 'double-bubble sign' in 18 cases, the distal bowel without gas in 5 cases, small amount of gas in the distal bowel in 15 cases. In 12 of 18 cases showing 'double-bubble sign', the ratio of duodenal bubble diameter (Dd) to stomach bubble diameter (Ds)was over 1.0. The site of obstruction was located in the descending duodenum in 20 cases. The form of obstructed point presented with 'nipple sign' in 15 cases, with 'the mouse tail' in 5 cases. The expansion bowel was located in the head of pancreas in 1 case. Gas was found in the pancreatic duct in 1 case, and 'swirl sign' was shown in 2 cases. Conclusions: MSCT combined with three-dimensional reconstruction techniques can clearly demonstrate the annular pancreas' s shape, the site and degree of obstruction and other malformations. It can provide important information for clinical treatment. (authors)

  10. Posttraumatic venous gas in the liver - a case report and review of the current literature.

    Science.gov (United States)

    Fahrner, René; Rauchfuss, Falk; Scheuerlein, Hubert; Settmacher, Utz

    2018-03-02

    There are numerous causes of hepatic gas formation that range from serious pathologies to incidental findings, including mesenteric infarction, liver abscess, inflammatory bowel disease or minimally invasive hepatic interventions. We report a case of a 50-year-old man who was admitted to the emergency room after a car accident. The clinical examination and further diagnostics revealed a craniocerebral injury with a fracture of the skull, concomitant soft tissue lesions and subarachnoidal bleeding. Furthermore, a blunt thoracic trauma with hemopneumothorax due to rib fractures was treated with a chest tube. No obvious abdominal pathology was seen. While in the operating theatre for the surgical revision of the cranial soft tissue lesions, a femoral venous catheter was inserted without any complications. A routine ultrasound of the abdomen six hours after the trauma revealed unclear hepatic gas formation. A contrast-enhanced computer tomography (CT) scan of the abdomen was performed, and the gas formation was found to be localized within the left hepatic vein. Afterwards, there was no specific treatment of the hepatic venous gas formation, as no alterations of liver function or liver enzymes were seen. The further course of the patient was uneventful regarding the gas formation in the liver, and another ultrasound two days later revealed no further gas in the liver. The placement of a femoral venous catheter is a risk factor for gas formation in liver veins. No further treatment is needed in cases with stable liver function. To rule out serious pathologies, diagnostic findings (e.g., ultrasound, CT), clinical history and underlying diseases need to be analyzed carefully after the detection of intrahepatic gas formation. With contrast-enhanced CT, the localization of the gas and its potential causes might be detectable.

  11. CT findings of pancreatic carcinoma. Evaluation with the combined method of early enhancement CT and high dose enhancement CT

    International Nuclear Information System (INIS)

    Itoh, Shigeki; Endo, Tokiko; Isomura, Takayuki; Ishigaki, Takeo; Ikeda, Mitsuru; Senda, Kouhei.

    1995-01-01

    Computed tomographic (CT) findings of pancreatic ductal adenocarcinoma were studied with the combined method of early enhancement CT and high dose enhancement CT in 72 carcinomas. Common Findings were change in pancreatic contour, abnormal attenuation in a tumor and dilatation of the main pancreatic duct. The incidence of abnormal attenuation and dilatation of the main pancreatic duct and bile duct was constant regardless of tumor size. The finding of hypoattenuation at early enhancement CT was most useful for demonstrating a carcinoma. However, this finding was negative in ten cases, five of which showed inhomogenous hyperattenuation at high dose enhancement CT. The detection of change in pancreatic contour and dilatation of the main pancreatic duct was most frequent at high dose enhancement CT. The finding of change in pancreatic contour and/or abnormal attenuation in a tumor could be detected in 47 cases at plain CT, 66 at early enhancement CT and 65 at high dose enhancement CT. Since the four cases in which neither finding was detected by any CT method showed dilatated main pancreatic duct, there was no case without abnormal CT findings. This combined CT method will be a reliable diagnostic technique in the imaging of pancreatic carcinoma. (author)

  12. Gas Transport Through Porous Strata from Underground Reaction Source; the Influence of the Gas Kind, Temperature and Transport-Pore Size

    Czech Academy of Sciences Publication Activity Database

    Šolcová, Olga; Soukup, Karel; Rogut, J.; Stanczyk, K.; Schneider, Petr

    2009-01-01

    Roč. 90, č. 12 (2009), s. 1495-1501 ISSN 0378-3820 Grant - others:RFCR(XE) CT/2007/00006 Institutional research plan: CEZ:AV0Z40720504 Keywords : underground coal gas ification * diffusion * permeation Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 2.321, year: 2009

  13. CT in neuromuscular disorders: A comparison of CT and histology

    International Nuclear Information System (INIS)

    Vliet, A.M. van der; Thijssen, H.O.M.; Merx, J.L.; Joosten, E.

    1988-01-01

    The value of CT-examination of the muscles compared to histology was studied in a retrospective analysis of 30 patients with clinical suspicion of neuromuscular disorder. In the evaluation of the CT-results descriptive criteria were used. The histologic diagnosis came from needle-biopsies taken from the quadriceps muscle. Considering the whole group of neuromuscular disorders, CT has an overall accuracy of 84.8%, a positive predictive value of 95.5% and a negative predictive value of 63.6%. This makes the use of CT as a diagnostic tool in neuromuscular disorders a reliable examination technique. In patients with a polymyositis there is even a 100% correlation between CT findings and biopsy results. Discrepancy between the biopsy results is remarkable of the quadriceps muscle and the CT findings: The number of abnormal histological findings is twice the number of abnormal CT findings. Using the more proximal gluteal region as a biopsy site would have decreased this discrepancy and would therefore have given a better correlation between CT and histology. The choice of protocol in determining the levels to be scanned is of great importance in achieving good reproducability in follow-up CT examinations. (orig.)

  14. Combined SPECT/CT and PET/CT for breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Russo, Paolo [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Larobina, Michele [Istituto di Biostrutture e Bioimmagini, Consiglio Nazionale delle Ricerche, Via Tommaso De Amicis, 95, Naples I-80145 (Italy); Di Lillo, Francesca [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Del Vecchio, Silvana [Università di Napoli Federico II, Dipartimento di Scienze Biomediche Avanzate, Via Pansini, 5, Naples I-80131 (Italy); Mettivier, Giovanni, E-mail: mettivier@na.infn.it [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy)

    2016-02-11

    In the field of nuclear medicine imaging, breast imaging for cancer diagnosis is still mainly based on 2D imaging techniques. Three-dimensional tomographic imaging with whole-body PET or SPECT scanners, when used for imaging the breast, has performance limits in terms of spatial resolution and sensitivity, which can be overcome only with a dedicated instrumentation. However, only few hybrid imaging systems for PET/CT or SPECT/CT dedicated to the breast have been developed in the last decade, providing complementary functional and anatomical information on normal breast tissue and lesions. These systems are still under development and clinical trials on just few patients have been reported; no commercial dedicated breast PET/CT or SPECT/CT is available. This paper reviews combined dedicated breast PET/CT and SPECT/CT scanners described in the recent literature, with focus on their technological aspects.

  15. CT portography by multidetector helical CT. Comparison of three rendering models

    International Nuclear Information System (INIS)

    Nakayama, Yoshiharu; Imuta, Masanori; Funama, Yoshinori; Kadota, Masataka; Utsunomiya, Daisuke; Shiraishi, Shinya; Hayashida, Yoshiko; Yamashita, Yasuyuki

    2002-01-01

    The purpose of this study was to assess the value of multidetector CT portography in visualizing varices and portosystemic collaterals in comparison with conventional portography, and to compare the visualizations obtained by three rendering models (volume rendering, VR; minimum intensity projection, MIP; and shaded surface display, SSD). A total of 46 patients with portal hypertension were examined by CT and conventional portography for evaluation of portosystemic collaterals. CT portography was performed by multidetector CT (MD-CT) scanner with a slice thickness of 2.5 mm and table feed of 7.5 mm. Three types of CT portographic models were generated and compared with transarterial portography. Among 46 patients, 48 collaterals were identified on CT transverse images, while 38 collaterals were detected on transarterial portography. Forty-four of 48 collaterals identified on CT transverse images were visualized with the MIP model, while 34 and 29 collaterals were visualized by the VR and SSD methods, respectively. The average CT value for the portal vein and varices was 198 HU with data acquisition of 50 sec after contrast material injection. CT portography by multidetector CT provides excellent images in the visualization of portosystemic collaterals. The images of collaterals produced by MD-CT are superior to those of transarterial portography. Among the three rendering techniques, MIP provides the best visualization of portosystemic collaterals. (author)

  16. CT portography by multidetector helical CT. Comparison of three rendering models

    Energy Technology Data Exchange (ETDEWEB)

    Nakayama, Yoshiharu; Imuta, Masanori; Funama, Yoshinori; Kadota, Masataka; Utsunomiya, Daisuke; Shiraishi, Shinya; Hayashida, Yoshiko; Yamashita, Yasuyuki [Kumamoto Univ. (Japan). School of Medicine

    2002-12-01

    The purpose of this study was to assess the value of multidetector CT portography in visualizing varices and portosystemic collaterals in comparison with conventional portography, and to compare the visualizations obtained by three rendering models (volume rendering, VR; minimum intensity projection, MIP; and shaded surface display, SSD). A total of 46 patients with portal hypertension were examined by CT and conventional portography for evaluation of portosystemic collaterals. CT portography was performed by multidetector CT (MD-CT) scanner with a slice thickness of 2.5 mm and table feed of 7.5 mm. Three types of CT portographic models were generated and compared with transarterial portography. Among 46 patients, 48 collaterals were identified on CT transverse images, while 38 collaterals were detected on transarterial portography. Forty-four of 48 collaterals identified on CT transverse images were visualized with the MIP model, while 34 and 29 collaterals were visualized by the VR and SSD methods, respectively. The average CT value for the portal vein and varices was 198 HU with data acquisition of 50 sec after contrast material injection. CT portography by multidetector CT provides excellent images in the visualization of portosystemic collaterals. The images of collaterals produced by MD-CT are superior to those of transarterial portography. Among the three rendering techniques, MIP provides the best visualization of portosystemic collaterals. (author)

  17. CT arterial portography and CT arteriography with a triple-lumen balloon catheter

    International Nuclear Information System (INIS)

    Murakami, T.; Oi, H.; Hori, M.; Kim, T.; Takahashi, S.; Matsushita, M.; Narumi, Y.; Nakamura, H.

    1997-01-01

    Purpose: To evaluate the usefulness of the triple-lumen balloon catheter in the serial performance of CT arterial portography (CT-AP) and CT arteriography (CT-A). Material and Methods: A combined CT-AP and CT-A examination of 58 patients was carried out in which a cobra-type triple-lumen balloon catheter was used. CT-AP was performed by injecting contrast medium either into the splenic artery through a side-hole in the catheter proximal to the balloon inflated in the common hepatic artery, or into the superior mesentric artery through an end-hole in the catheter. Then CT-A was serially performed by delivering contrast medium either to the common hepatic artery or the proper hepatic artery from the end-hole, or to the accessory right hepatic artery through a side-hole proximal to the inflated balloon. Results: Sufficient CT-APs were obtained in 53 of the 58 patients (91%), CT-A in 42 (72%), and both in 42 (72%). Incomplete CT-AP was due to technical failure or anatomical anomaly, as was incomplete CT-A. No complications were seen. (orig.)

  18. CT-Urography; Urografia CT

    Energy Technology Data Exchange (ETDEWEB)

    Dalla Palma, Ludovico; Grotto, Maurizio [Trieste Univ., Trieste (Italy). Dipartimento di scienze cliniche, morfologiche e tecnologiche, UCO di radiologia; Morra, Aldo [CRO, Aviano (Italy). Reparto di radiologia

    2005-09-15

    In this paper we present an overview of CT-Urography. With the advent of multislice CT scanners and the evolution of image processing methods this technique now affords optimal urographic images comparable to those obtained with conventional techniques. We describe the acquisition techniques and protocols used by the various authors. Effective radiation dose has conditioned the use of CT-Urography so that the tendency today is to reduce the number of scans by performing, after the non enhanced scan, a single contrast-enhanced scan comprising both the nephrographic and urographic phase. With the use of multislice CT the quality of the urogram improves with the number of slices. We illustrate a variety of processing techniques, multiplanar reconstruction (MPR), maximum (MIP) and average intensity projection (AIP) and volume rendering (VR) and present a series of upper urinary tract tumours testifying to the superiority of the AIP technique over MIP. We then review the results of comparative studies of CT-Urography with conventional urography in upper urinary tract diagnostics. Finally, we describe the advantages and limitations of CT-Urography. [Italian] Gli Autori presentano una panoramica sulla Urografia TC (Uro TC). L'avvento della TC multistrato e l'evoluzione delle tecniche di elaborazione consentono di ottenere dei quadri urografici ottimali comparativi con quelli convenzionali. Vengono ricordate le varie tecniche di acquisizione e i protocolli usati dai vari Autori. La dose effettiva di radiazioni ha rappresentato uno dei fattori condizionanti per cui oggi prevale l'orientamento di ridurre il numero di scansioni, considerando dopo la scansione senza mezzo di contrasto un'unica scansione contrasto grafica comprendente sia la fase nefrografica che quella urografica. Con l'uso della TC multistrato la qualita dell'urogramma migliora con l'aumento del numero degli strati. Vengono descritte le varie tecniche di elaborazione, la

  19. Comparison of CT and PET/CT for biopsy guidance in oncological patients

    Energy Technology Data Exchange (ETDEWEB)

    Cerci, Juliano J.; Bogoni, Mateos; Cunha Pereira, Carlos; Cerci, Rodrigo J.; Krauzer, Cassiano; Vicente Vitola, Joao [Quanta - Diagnostico e Terapia, Curitiba, PR (Brazil); Tabacchi, Elena; Fanti, Stefano [University Hospital S. Orsola-Malpighi, Nuclear Medicine Department, Bologna (Italy); Delbeke, Dominique [Vanderbilt University, Nashville, TN (United States); Giacometti Sakamoto, Danielle [Byori - Laboratorio de Patologia, Curitiba (Brazil)

    2017-08-15

    To compare FDG PET/CT and CT for the guidance of percutaneous biopsies with histological confirmation of lesions. We prospectively evaluated 323 patients of whom 181 underwent FDG PET/CT-guided biopsy (total 188 biopsies) and 142 underwent CT-guided biopsy (total 146 biopsies). Biopsies were performed using the same PET/CT scanner with a fluoroscopic imaging system. Technical feasibility, clinical success and complication rates in the two groups were evaluated. Of the 188 biopsies with PET/CT guidance, 182 (96.8%) were successful with conclusive tissue samples obtained and of the 146 biopsies with CT guidance, 137 (93.8%) were successful. Therefore, 6 of 188 biopsies (3.1%) with PET/CT guidance and 9 of 146 (6.1%) with CT guidance were inconclusive (p = 0.19). Due to inconclusive histological results, 4 of the 188 lesions (2.1%) were rebiopsied with PET/CT guidance and 3 of 146 lesions (2.0%) were rebiopsied with CT guidance. Histology demonstrated that 142 of 188 lesions (75.5%) were malignant, and 40 (21.2%) were benign in the PET/CT-guided group, while 89 of 146 lesions (60.9%) were malignant and 48 (32.8%) were benign in the CT-guided group (p = 0.004 and 0.01, respectively). Patients with a histological diagnosis of benign lesion had no recurrence of disease with a minimum of 6 months follow-up. Of the 188 PET/CT-guided biopsies, 6 (3.1%) were repeat biopsies due to a previous nondiagnostic CT-guided biopsy performed in a different diagnostic centre. The interval between the two biopsies was less than a month in all cases. Histology revealed five malignant lesions and one benign lesion among these. The complication rate in the PET/CT-guided biopsy group was 12.7% (24 of 188), while in the CT-guided group, was 9.5% (14 of 146, p = 0.26). Therefore, there was no significant difference in complication rates between PET/CT and CT guidance. PET/CT-guided biopsy is already known to be a feasible and accurate method in the diagnostic work-up of suspected malignant

  20. Comparison of CT and PET/CT for biopsy guidance in oncological patients

    International Nuclear Information System (INIS)

    Cerci, Juliano J.; Bogoni, Mateos; Cunha Pereira, Carlos; Cerci, Rodrigo J.; Krauzer, Cassiano; Vicente Vitola, Joao; Tabacchi, Elena; Fanti, Stefano; Delbeke, Dominique; Giacometti Sakamoto, Danielle

    2017-01-01

    To compare FDG PET/CT and CT for the guidance of percutaneous biopsies with histological confirmation of lesions. We prospectively evaluated 323 patients of whom 181 underwent FDG PET/CT-guided biopsy (total 188 biopsies) and 142 underwent CT-guided biopsy (total 146 biopsies). Biopsies were performed using the same PET/CT scanner with a fluoroscopic imaging system. Technical feasibility, clinical success and complication rates in the two groups were evaluated. Of the 188 biopsies with PET/CT guidance, 182 (96.8%) were successful with conclusive tissue samples obtained and of the 146 biopsies with CT guidance, 137 (93.8%) were successful. Therefore, 6 of 188 biopsies (3.1%) with PET/CT guidance and 9 of 146 (6.1%) with CT guidance were inconclusive (p = 0.19). Due to inconclusive histological results, 4 of the 188 lesions (2.1%) were rebiopsied with PET/CT guidance and 3 of 146 lesions (2.0%) were rebiopsied with CT guidance. Histology demonstrated that 142 of 188 lesions (75.5%) were malignant, and 40 (21.2%) were benign in the PET/CT-guided group, while 89 of 146 lesions (60.9%) were malignant and 48 (32.8%) were benign in the CT-guided group (p = 0.004 and 0.01, respectively). Patients with a histological diagnosis of benign lesion had no recurrence of disease with a minimum of 6 months follow-up. Of the 188 PET/CT-guided biopsies, 6 (3.1%) were repeat biopsies due to a previous nondiagnostic CT-guided biopsy performed in a different diagnostic centre. The interval between the two biopsies was less than a month in all cases. Histology revealed five malignant lesions and one benign lesion among these. The complication rate in the PET/CT-guided biopsy group was 12.7% (24 of 188), while in the CT-guided group, was 9.5% (14 of 146, p = 0.26). Therefore, there was no significant difference in complication rates between PET/CT and CT guidance. PET/CT-guided biopsy is already known to be a feasible and accurate method in the diagnostic work-up of suspected malignant

  1. Biomechanical CT Metrics Are Associated With Patient Outcomes in COPD

    Science.gov (United States)

    Bodduluri, Sandeep; Bhatt, Surya P; Hoffman, Eric A.; Newell, John D.; Martinez, Carlos H.; Dransfield, Mark T.; Han, Meilan K.; Reinhardt, Joseph M.

    2017-01-01

    Background Traditional metrics of lung disease such as those derived from spirometry and static single-volume CT images are used to explain respiratory morbidity in patients with chronic obstructive pulmonary disease (COPD), but are insufficient. We hypothesized that the mean Jacobian determinant, a measure of local lung expansion and contraction with respiration, would contribute independently to clinically relevant functional outcomes. Methods We applied image registration techniques to paired inspiratory-expiratory CT scans and derived the Jacobian determinant of the deformation field between the two lung volumes to map local volume change with respiration. We analyzed 490 participants with COPD with multivariable regression models to assess strengths of association between traditional CT metrics of disease and the Jacobian determinant with respiratory morbidity including dyspnea (mMRC), St Georges Respiratory Questionnaire (SGRQ) score, six-minute walk distance (6MWD), and the BODE index, as well as all-cause mortality. Results The Jacobian determinant was significantly associated with SGRQ (adjusted regression co-efficient β = −11.75,95%CI −21.6 to −1.7;p=0.020), and with 6MWD (β=321.15, 95%CI 134.1 to 508.1;p<0.001), independent of age, sex, race, body-mass-index, FEV1, smoking pack-years, CT emphysema, CT gas trapping, airway wall thickness, and CT scanner protocol. The mean Jacobian determinant was also independently associated with the BODE index (β= −0.41, 95%CI −0.80 to −0.02; p = 0.039), and mortality on follow-up (adjusted hazards ratio = 4.26, 95%CI = 0.93 to 19.23; p = 0.064). Conclusion Biomechanical metrics representing local lung expansion and contraction improve prediction of respiratory morbidity and mortality and offer additional prognostic information beyond traditional measures of lung function and static single-volume CT metrics. PMID:28044005

  2. CT-derived Biomechanical Metrics Improve Agreement Between Spirometry and Emphysema.

    Science.gov (United States)

    Bhatt, Surya P; Bodduluri, Sandeep; Newell, John D; Hoffman, Eric A; Sieren, Jessica C; Han, Meilan K; Dransfield, Mark T; Reinhardt, Joseph M

    2016-10-01

    Many patients with chronic obstructive pulmonary disease (COPD) have marked discordance between forced expiratory volume in 1 second (FEV1) and degree of emphysema on computed tomography (CT). Biomechanical differences between these patients have not been studied. We aimed to identify reasons for the discordance between CT and spirometry in some patients with COPD. Subjects with Global initiative for chronic Obstructive Lung Disease stages I-IV from a large multicenter study (The Genetic Epidemiology of COPD) were arranged by percentiles of %predicted FEV1 and emphysema on CT. Three categories were created using differences in percentiles: Catspir with predominant airflow obstruction/minimal emphysema, CatCT with predominant emphysema/minimal airflow obstruction, and Catmatched with matched FEV1 and emphysema. Image registration was used to derive Jacobian determinants, a measure of lung elasticity, anisotropy, and strain tensors, to assess biomechanical differences between groups. Regression models were created with the previously mentioned categories as outcome variable, adjusting for demographics, scanner type, quantitative CT-derived emphysema, gas trapping, and airway thickness (model 1), and after adding biomechanical CT metrics (model 2). Jacobian determinants, anisotropy, and strain tensors were strongly associated with FEV1. With Catmatched as control, model 2 predicted Catspir and CatCT better than model 1 (Akaike information criterion 255.8 vs. 320.8). In addition to demographics, the strongest independent predictors of FEV1 were Jacobian mean (β = 1.60,95%confidence intervals [CI] = 1.16 to 1.98; P spirometry, offering the potential for new insights into the linkage between regional parenchymal destruction and global decrement in lung function in patients with COPD. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  3. Reconciling the cosmic age problem in the R{sub h} = ct universe

    Energy Technology Data Exchange (ETDEWEB)

    Yu, H. [Nanjing University, School of Astronomy and Space Science, Nanjing (China); Wang, F.Y. [Nanjing University, School of Astronomy and Space Science, Nanjing (China); Key Laboratory of Modern Astronomy and Astrophysics, Nanjing University, Ministry of Education, Nanjing (China)

    2014-10-15

    Many dark energy models fail to pass the cosmic age test. In this paper, we investigate the cosmic age problem associated with nine extremely old Global Clusters (GCs) and the old quasar APM 08279+5255 in the R{sub h} = ct universe. The age data of these oldest GCs in M31 are acquired from the Beijing-Arizona-Taiwan-Connecticut system with up-to-date theoretical synthesis models. They have not been used to test the cosmic age problem in the R{sub h} = ct universe in previous literature. By evaluating the age of the R{sub h} = ct universe with the observational constraints from the type Ia supernovae and the Hubble parameter, we find that the R{sub h} = ct universe can accommodate five GCs and the quasar APM 08279+5255 at redshift z = 3.91. But for other models, such as ΛCDM, the interacting dark energy model, the generalized Chaplygin gas model, and holographic dark energy model, cannot accommodate all GCs and the quasar APM 08279+5255. It is worthwhile to note that the age estimates of some GCs are controversial. So, unlike other cosmological models, the R{sub h} = ct universe can marginally solve the cosmic age problem, especially at high redshift. (orig.)

  4. Optimization of Protocol CT, PET-CT, whole body; Optimizacion de protocolo CT, en PET-CT, de cuerpo entero

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez, Fredys Santos, E-mail: fsantos@ccss.sa.cr [Caja Costarricense de Seguro Social (ACCPR/CCSS), San Jose (Costa Rica). Area Control de Calidade Y Proteccion Radiologica; Namias, Mauro, E-mail: mnamias@gmail.com [Comision Nacional de Energia Atomica (FCDN/CNEA), Buenos Aires (Argentina). Fundacion Centro Diagnostico Nuclear

    2013-11-01

    The objective of this study was to optimize the acquisition protocols and processing existing of the CT PET/CT scanner for clinical use of Nuclear Diagnostic Center Foundation, a way to minimize the radiation dose while maintaining diagnostic image quality properly. Dosimetric data of PET / CT service were surveyed and obtained the baseline against which we compare and define strategies and modifications to develop online. We selected transaxial up to the pulmonary hilum and liver slices as the anatomical regions of interest that led to the standardization of the study.

  5. New possibilities in the diagnosis of ischemia. CT-FFR and CT-Perfusion; Neue Moeglichkeiten der Ischaemiediagnostik. CT-FFR und CT-Perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Lehmkuhl, Lukas [Herz- und Gefaessklinik, Bad Neustadt an der Saale (Germany). Abt. fuer Radiologie; Krieghoff, Christian [Herzzentrum Leipzig (Germany); Gutberlet, Matthias [Herzzentrum Leipzig (Germany). Abt. fuer Diagnostische und Interventionelle Radiologie; Leipzig Univ. (Germany). Kardiologische Bildgebung

    2017-12-15

    Coronary CT-angiography (CCTA) plays an increasing role in the primary diagnostics of coronary artery disease (CAD) according to the present guidelines but also in clinical reality. The sensitivity and negative predictive value of CCTA is very high, but the specificity could still be improved. Newer techniques to assess myocardial ischemia like CT-FFR and CT-Perfusion may help to achieve that goal.

  6. CT of laryngotracheal trauma

    International Nuclear Information System (INIS)

    Lupetin, A.R.; Daffner, R.H.

    1991-01-01

    This paper evaluates the usefulness of CT for the diagnosis of traumatic laryngotracheal abnormalities. The authors retrospectively evaluated the neck CT studies of 50 patients (36 males, 14 females; age range, 16-75 years) who presented to a level I trauma center after suffering a blunt or penetrating laryngotracheal injury. CT results were correlated with endoscopic or surgical findings in 43 cases. Three groups emerge. CT positive: hyloid bone or laryngotracheal cartilage injury; CT positive: soft-tissue injury only; and CT negative. In group 1, CT demonstrated all bony or cartilaginous injuries proved at surgery or suggested at endoscopy. CT failed to demonstrate laryngotracheal separation in 1 case. In group 2, CT demonstrated all soft-tissue injuries suggested at endoscopy. In group 3, CT findings agreed with those of endoscopy in 7 cases, but minor soft-tissue findings seen at endoscopy were missed in 3 cases. Seven patients were studied only with CT. Ct is an accurate technique for detecting bony or cartilaginous laryngotracheal traumatic abnormalities. However, laryngotracheal separation and minor soft-tissue injuries can be missed

  7. CT-Urography

    International Nuclear Information System (INIS)

    Dalla Palma, Ludovico; Grotto, Maurizio; Morra, Aldo

    2005-01-01

    In this paper we present an overview of CT-Urography. With the advent of multislice CT scanners and the evolution of image processing methods this technique now affords optimal urographic images comparable to those obtained with conventional techniques. We describe the acquisition techniques and protocols used by the various authors. Effective radiation dose has conditioned the use of CT-Urography so that the tendency today is to reduce the number of scans by performing, after the non enhanced scan, a single contrast-enhanced scan comprising both the nephrographic and urographic phase. With the use of multislice CT the quality of the urogram improves with the number of slices. We illustrate a variety of processing techniques, multiplanar reconstruction (MPR), maximum (MIP) and average intensity projection (AIP) and volume rendering (VR) and present a series of upper urinary tract tumours testifying to the superiority of the AIP technique over MIP. We then review the results of comparative studies of CT-Urography with conventional urography in upper urinary tract diagnostics. Finally, we describe the advantages and limitations of CT-Urography [it

  8. CT vs 68Ge attenuation correction in a combined PET/CT system: evaluation of the effect of lowering the CT tube current

    International Nuclear Information System (INIS)

    Kamel, Ehab; Hany, Thomas F.; Burger, Cyrill; Treyer, Valerie; Schulthess von, Gustav K.; Buck, Alfred; Lonn, Albert H.R.

    2002-01-01

    With the introduction of combined positron emission tomography/computed tomography (PET/CT) systems, several questions have to be answered. In this work we addressed two of these questions: (a) to what value can the CT tube current be reduced while still yielding adequate maps for the attenuation correction of PET emission scans and (b) how do quantified uptake values in tumours derived from CT and germanium-68 attenuation correction compare. In 26 tumour patients, multidetector CT scans were acquired with 10, 40, 80 and 120 mA (CT 10 , CT 40 , CT 80 and CT 120 ) and used for the attenuation correction of a single FDG PET emission scan, yielding four PET scans designated PET CT10 -PET CT120 . In 60 tumorous lesions, FDG uptake and lesion size were quantified on PET CT10 -PET CT120 . In another group of 18 patients, one CT scan acquired with 80 mA and a standard transmission scan acquired using 68 Ge sources were employed for the attenuation correction of the FDG emission scan (PET CT80 , PET 68Ge ). Uptake values and lesion size in 26 lesions were compared on PET CT80 and PET 68Ge . In the first group of patients, analysis of variance revealed no significant effect of CT current on tumour FDG uptake or lesion size. In the second group, tumour FDG uptake was slightly higher using CT compared with 68 Ge attenuation correction, especially in lesions with high FDG uptake. Lesion size was similar on PET CT80 and PET 68Ge . In conclusion, low CT currents yield adequate maps for the attenuation correction of PET emission scans. Although the discrepancy between CT- and 68 Ge-derived uptake values is probably not relevant in most cases, it should be kept in mind if standardised uptake values derived from CT and 68 Ge attenuation correction are compared. (orig.)

  9. Effects of short-term pressure-controlled ventilation on gas exchange, airway pressures, and gas distribution in patients with acute lung injury/ARDS: comparison with volume-controlled ventilation.

    Science.gov (United States)

    Prella, Maura; Feihl, François; Domenighetti, Guido

    2002-10-01

    The potential clinical benefits of pressure-controlled ventilation (PCV) over volume-controlled ventilation (VCV) in patients with acute lung injury (ALI) or ARDS still remain debated. We compared PCV with VCV in patients with ALI/ARDS with respect to the following physiologic end points: (1) gas exchange and airway pressures, and (2) CT scan intrapulmonary gas distribution at end-expiration. Prospective, observational study. A multidisciplinary ICU in a nonuniversity, acute-care hospital. Ten patients with ALI or ARDS (9 men and 1 woman; age range, 17 to 80 years). Sequential ventilation in PCV and VCV with a constant inspiratory/expiratory ratio, tidal volume, respiratory rate, and total positive end-expiratory pressure; measurement of gas exchange and airway pressures; and achievement of CT sections at lung base, hilum, and apex for the quantitative analysis of lung densities and of aerated vs nonaerated zones. PaO(2), PaCO(2), and PaO(2)/fraction of inspired oxygen ratio levels did not differ between PCV and VCV. Peak airway pressure (Ppeak) was significantly lower in PCV compared with VCV (26 +/- 2 cm H(2)O vs 31 +/- 2 cm H(2)O; p mean +/- SEM). The surface areas of the nonaerated zones as well as the total areas at each section level were unchanged in PCV compared with VCV, except at the apex level, where there was a significantly greater nonaerated area in VCV (11 +/- 2 cm(2) vs 9 +/- 2 cm(2); p mean CT number of each lung (20 lungs from 10 patients) was similar in the two modes, as were the density values at the basal and apical levels; the hilum mean CT number was - 442 +/- 28 Hounsfield units (HU) in VCV and - 430 +/- 26 HU in PCV (p lower Ppeaks through the precise titration of the lung distending pressure, and might be applied to avoid regional overdistension by means of a more homogeneous gas distribution.

  10. Whole-body CT. Spiral and multislice CT. 2. tot. rev. and enl. ed.; Ganzkoerper-Computertomographie. Spiral- und Multislice-CT

    Energy Technology Data Exchange (ETDEWEB)

    Prokop, M.; Galanski, M.; Schaefer-Prokop, C.; Molen, A.J. van der

    2007-07-01

    Spiral and multidetector techniques have improved the diagnostic possibilities of CT, so that image analysis and interpretation have become increasingly complex. This book represents the current state of the art in CT imaging, including the most recent technical scanner developments. The second edition comprises the current state of knowledge in cT imaging. There are new chapters on image processing, application of contrasting agents and radiation dose. All organ-specific pathological findings are discussed in full. There are hints for optimum use and interpretation of CT, including CT angiography, CT colonography, CT-IVPL, and 3D imaging. There is an introduction to cardio-CT, from calcium scoring and CTA of the coronary arteries to judgement of cardiac morphology. There are detailed scan protocols with descriptions of how to go about parameter selection. Practical hints are given for better image quality and lower radiation exposure of patients, guidelines for patient preparation and complication management, and more than 1900 images in optimum RRR quality. (orig.)

  11. Image Registration for PET/CT and CT Images with Particle Swarm Optimization

    International Nuclear Information System (INIS)

    Lee, Hak Jae; Kim, Yong Kwon; Lee, Ki Sung; Choi, Jong Hak; Kim, Chang Kyun; Moon, Guk Hyun; Joo, Sung Kwan; Kim, Kyeong Min; Cheon, Gi Jeong

    2009-01-01

    Image registration is a fundamental task in image processing used to match two or more images. It gives new information to the radiologists by matching images from different modalities. The objective of this study is to develop 2D image registration algorithm for PET/CT and CT images acquired by different systems at different times. We matched two CT images first (one from standalone CT and the other from PET/CT) that contain affluent anatomical information. Then, we geometrically transformed PET image according to the results of transformation parameters calculated by the previous step. We have used Affine transform to match the target and reference images. For the similarity measure, mutual information was explored. Use of particle swarm algorithm optimized the performance by finding the best matched parameter set within a reasonable amount of time. The results show good agreements of the images between PET/CT and CT. We expect the proposed algorithm can be used not only for PET/CT and CT image registration but also for different multi-modality imaging systems such as SPECT/CT, MRI/PET and so on.

  12. The effect of the cranial bone CT numbers on the brain CT numbers

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, Hitoshi; Kobayashi, Shotai; Koide, Hiromi; Yamaguchi, Shuhei; Okada, Kazunori; Shimote, Koichi; Tsunematsu, Tokugoro (Shimane Medical Univ., Izumo (Japan))

    1989-06-01

    The effects of the cranial size and the computed tomography (CT) numbers of the cranial bone on that of the brain were studied in 70 subjects, aged from 30 to 94 years. The subjects had no histories of cerebrovascular accidents and showed no abnormalities in the central nervous system upon physical examinations and a CT scan. We measured the average attenuation values (CT numbers) of each elliptical region (165 pixels, 0.39 cm{sup 2}) at the bilateral thalamus and at twelve areas of the deep white matter. Multiple regression analysis was used to assess the effects of age, cranial size, and cranial bone CT numbers on the brain CT numbers. The effect of the cranial bone CT numbers on the brain CT numbers was statistically significant. The brain CT numbers increased with the increase in the cranial bone CT numbers. There was, however, no significant correlation between brain CT numbers and cranial size. In measuring the brain CT numbers, it is desirable that consideration be given to the cranial bone CT numbers. (author).

  13. Bone quality evaluation at dental implant site using multislice CT, micro-CT, and cone beam CT.

    Science.gov (United States)

    Parsa, Azin; Ibrahim, Norliza; Hassan, Bassam; van der Stelt, Paul; Wismeijer, Daniel

    2015-01-01

    The first purpose of this study was to analyze the correlation between bone volume fraction (BV/TV) and calibrated radiographic bone density Hounsfield units (HU) in human jaws, derived from micro-CT and multislice computed tomography (MSCT), respectively. The second aim was to assess the accuracy of cone beam computed tomography (CBCT) in evaluating trabecular bone density and microstructure using MSCT and micro-CT, respectively, as reference gold standards. Twenty partially edentulous human mandibular cadavers were scanned by three types of CT modalities: MSCT (Philips, Best, the Netherlands), CBCT (3D Accuitomo 170, J Morita, Kyoto, Japan), and micro-CT (SkyScan 1173, Kontich, Belgium). Image analysis was performed using Amira (v4.1, Visage Imaging Inc., Carlsbad, CA, USA), 3Diagnosis (v5.3.1, 3diemme, Cantu, Italy), Geomagic (studio(®) 2012, Morrisville, NC, USA), and CTAn (v1.11, SkyScan). MSCT, CBCT, and micro-CT scans of each mandible were matched to select the exact region of interest (ROI). MSCT HU, micro-CT BV/TV, and CBCT gray value and bone volume fraction of each ROI were derived. Statistical analysis was performed to assess the correlations between corresponding measurement parameters. Strong correlations were observed between CBCT and MSCT density (r = 0.89) and between CBCT and micro-CT BV/TV measurements (r = 0.82). Excellent correlation was observed between MSCT HU and micro-CT BV/TV (r = 0.91). However, significant differences were found between all comparisons pairs (P micro-CT BV/TV (P = 0.147). An excellent correlation exists between bone volume fraction and bone density as assessed on micro-CT and MSCT, respectively. This suggests that bone density measurements could be used to estimate bone microstructural parameters. A strong correlation also was found between CBCT gray values and BV/TV and their gold standards, suggesting the potential of this modality in bone quality assessment at implant site. © 2013 John Wiley & Sons A/S. Published by

  14. Combined CT Angiography and CT Venography in Thromboembolic disease: clinical impact

    International Nuclear Information System (INIS)

    Bouzas, R.; Migueles, Y.; Gomez, S.; Mallo, R.; Garcia-Tejedor, J. L.; Diaz Vega, M. J.

    2002-01-01

    Combined CT Venography and Pulmonary Angiography was described in 1998 as a tool for diagnostic Thromboembolic Disease. The purpose is to relate our own experience with this technique in a population with suspected pulmonary embolism. 46 consecutive patients with suspected pulmonary embolism underwent combined CT Venography after Pulmonary CT Angiography to depict Deep Venous Thrombosis (DVT). CT Venography where obtained with a 3 minutes delay from injection, without additional intravenous contrast, from upper abdomen to fibular head. A prospective study from emergency reports where used. The reports where aimed by nine different radiologist at diary emergency room (images where not retrospective review). We report if a pulmonary embolus or deep venous thrombus or another alternative diagnostic where done. An endo luminal thrombus in any pulmonary arteries was assessed as a positive study for PE. A Thrombus in the leg veins or in an abdominal vein without diminished size of vein was assessed as an acute DVT. In those patients with a CT negative to Thromboembolic Disease was the clinician who decide if more proves where needed. Those patients without evidence in CT of Thromboembolic Disease where asked for symptoms related to the episode in a 3 months period after initial CT. Patients free of symptoms for 3 months without anticoagulation therapy where considered true negative for CT. CT shows Thromboembolic Disease in 23 of 46 patients. 21PE, 14 DVT 2 of 14 patients with DVT don't show PE, CT excluded thromboembolic disease in 23 patients and in 15 of those patients an alternative diagnostic was shown. In 22 of those 23 patients CT excluded correctly Thromboembolic Disease. One patient result in a false negative CT, Pulmonary Angiography of that patient shows us a subsegmentary embolus. (Author) 9 refs

  15. Picture analysis in CT-HF and its CT photographs

    International Nuclear Information System (INIS)

    Kubota, Kazuo; Kohirasawa, Hideo; Shinojima, Masayasu; Tokui, Mitsuru; Seo, Kunihiko.

    1980-01-01

    CT (computed tomography) apparatus is rarely used yet in the field of dentistry, though it seems useful. It is possibly because of the artefacts caused by the metallic parts attached to teeth, the large partial volume effect due to many bones and the problems of positioning and reproducibility. After considering the various requirements of the CT apparatuses in dental field, CT-HF (of T/R type) was chosen as such apparatus, and installed as the first in dentistry. In the CT-HF apparatus, the inner diameter of the gantry is up to 300 mm, and the position of a tomographic plane is only 40 mm away from the front of gantry. Mainly the usefulness of scanography in positioning and the usefulness of the CT apparatus in the picture analysis and processing in dental field are described. (J.P.N.)

  16. Gamma-ray CT from incomplete projections for two-phase pipe flow.

    Science.gov (United States)

    Xin, S; Wang, H X

    2017-02-01

    A low-energy low-dose γ-ray computed tomography (CT) system used in the gas-liquid two-phase pipe flow measurement has been studied at Tianjin University in recent years. The γ-ray CT system, having a third-generation X-ray CT scanning configuration, is comprised of one 300mCi 241 Am source and 17 CdZnTe detector units and achieves a spatial image resolution of about 7 mm. It is primarily intended to measure the two-phase pipe flow and provide improvement suggestions for industrial CT system. Recently we improve the design for image reconstruction from incomplete projection to optimize the scanning parameters and reduce the radiation dose. First, tomographic problem from incomplete projections is briefly described. Next, a system structure and a hardware circuit design are listed and explained, especially on time parameter setting of the pulse shaper. And then a detailed system analysis is provided in Section II, mainly focusing on spatial resolution, temporal resolution, system noise, and imaging algorithm. Finally, we carry on necessary static and dynamic experiments in a full scan (360°) and two sets of partial scan reconstruction tests to determine the feasibility of this γ-ray CT system for reconstructing the images from insufficient projections. And based on an A-variable algebraic reconstruction technique method, a specially designed algorithm, we evaluate the system performance and noise level of this CT system working quantitatively and qualitatively. Results of dynamic test indicate that the acceptable results can be acquired using a multi-source γ-ray CT system with the same parameters when the flow rate is less than 0.04 m/s and the imaging speed is slower than 33 frames/s.

  17. Additional value of PET-CT in the staging of lung cancer: comparison with CT alone, PET alone and visual correlation of PET and CT

    International Nuclear Information System (INIS)

    Wever, W. de; Marchal, G.; Bogaert, J.; Verschakelen, J.A.; Ceyssens, S.; Mortelmans, L.; Stroobants, S.

    2007-01-01

    Integrated positron emission tomography (PET) and computed tomography (CT) is a new imaging modality offering anatomic and metabolic information. The purpose was to evaluate retrospectively the accuracy of integrated PET-CT in the staging of a suggestive lung lesion, comparing this with the accuracy of CT alone, PET alone and visually correlated PET-CT. Fifty patients undergoing integrated PET-CT for staging of a suggestive lung lesion were studied. Their tumor, node, metastasis (TNM) statuses were determined with CT, PET, visually correlated PET-CT and integrated PET-CT. These TNM stages were compared with the surgical TNM status. Integrated PET-CT was the most accurate imaging technique in the assessment of the TNM status. Integrated PET-CT predicted correctly the T status, N status, M status and TNM status in, respectively, 86%, 80%, 98%, 70% versus 68%, 66%,88%, 46% with CT, 46%, 70%, 96%, 30% with PET and 72%, 68%, 96%, 54% with visually correlated PET-CT. T status and N status were overstaged, respectively, in 8% and 16% with integrated PET-CT, in 20% and 28% with CT, in 16% and 20% with PET, in 12% and 20% with visually correlated PET-CT and understaged in 6% and 4% with integrated PET-CT, versus 12% and 6% with CT, 38% and 10% with PET and 12% with visually correlated PET-CT. Integrated PET-CT improves the staging of lung cancer through a better anatomic localization and characterization of lesions and is superior to CT alone and PET alone. If this technique is not available, visual correlation of PET and CT can be a valuable alternative. (orig.)

  18. Metal artifact reduction of CT scans to improve PET/CT

    NARCIS (Netherlands)

    Van Der Vos, Charlotte S.; Arens, Anne I.J.; Hamill, James J.; Hofmann, Christian; Panin, Vladimir Y.; Meeuwis, Antoi P.W.; Visser, Eric P.; De Geus-Oei, Lioe Fee

    2017-01-01

    In recent years, different metal artifact reduction methods have been developed for CT. These methods have only recently been introduced for PET/CT even though they could be beneficial for interpretation, segmentation, and quantification of the PET/CT images. In this study, phantom and patient scans

  19. Metal Artifact Reduction of CT Scans to Improve PET/CT

    NARCIS (Netherlands)

    Vos, C.S. van der; Arens, A.I.J.; Hamill, J.J.; Hofmann, C.; Panin, V.Y.; Meeuwis, A.P.W.; Visser, E.P.; Geus-Oei, L.F. de

    2017-01-01

    In recent years, different metal artifact reduction methods have been developed for CT. These methods have only recently been introduced for PET/CT even though they could be beneficial for interpretation, segmentation, and quantification of the PET/CT images. In this study, phantom and patient scans

  20. Restaging of patients with lymphoma. Comparison of low dose CT (20 mAs) with contrast enhanced diagnostic CT in combined [18F]-FDG PET/CT

    International Nuclear Information System (INIS)

    Fougere, C. la; Pfluger, T.; Schneider, V.; Hacker, M.; Broeckel, N.; Bartenstein, P.; Tiling, R.; Morhard, D.; Hundt, W.; Becker, C.

    2008-01-01

    Aim: assessment of the clinical benefit of i.v. contrast enhanced diagnostic CT (CE-CT) compared to low dose CT with 20 mAs (LD-CT) without contrast medium in combined [ 18 F]-FDG PET/CT examinations in restaging of patients with lymphoma. Patients, methods: 45 patients with non-Hodgkin lymphoma (n = 35) and Hodgkin's disease (n = 10) were included into this study. PET, LD-CT and CE-CT were analyzed separately as well as side-by-side. Lymphoma involvement was evaluated separately for seven regions. Indeterminate diagnoses were accepted whenever there was a discrepancy between PET and CT findings. Results for combined reading were calculated by rating indeterminate diagnoses according the suggestions of either CT or PET. Each patient had a clinical follow-up evaluation for > 6 months. Results: region-based evaluation suggested a sensitivity/specificity of 66/93% for LD-CT, 87%/91% for CE-CT, 95%/96% for PET, 94%/99% for PET/LD-CT and 96%/99% for PET/CE-CT. The data for PET/CT were obtained by rating indeterminate results according to the suggestions of PET, which turned out to be superior to CT. Lymphoma staging was changed in two patients using PET/CE-CT as compared to PET/LD-CT. Conclusion: overall, there was no significant difference between PET/LD-CT and PET/CE-CT. However, PET/CE-CT yielded a more precise lesion delineation than PET/LD-CT. This was due to the improved image quality of CE-CT and might lead to a more accurate investigation of lymphoma. (orig.)

  1. CT and PET-CT of a Dog with Multiple Pulmonary Adenocarcinoma

    Science.gov (United States)

    KIM, Jisun; KWON, Seong Young; CENA, Rohani; PARK, Seungjo; OH, Juyeon; OUI, Heejin; CHO, Kyoung-Oh; MIN, Jung-Joon; CHOI, Jihye

    2013-01-01

    ABSTRACT A 10-year-old, intact female Yorkshire terrier had multiple pulmonary nodules on thoracic radiography and ultrasonography with no lesions elsewhere. Computed tomography (CT) and positron emission tomography and computed tomography (PET-CT) using 18F-fluorodeoxyglucose (FDG) were performed to identify metastasis and undetected primary tumors. On CT examination, pulmonary nodules had a hypoattenuating center with thin peripheral enhancement, suggesting ischemic or necrotizing lesion. In PET-CT at 47 min after intravenous injection of 11.1 MBq/kg of FDG, the maximum standardized uptake value of each pulmonary nodule was about from 3.8 to 6.4. There were no abnormal lesions except for four pulmonary nodules on the CT and PET-CT. Primary lung tumor was tentatively diagnosed, and palliative therapy using 2 mg/kg tramadol and 2.2 mg/kg carprofen twice per day was applied. After the dog’s euthanasia due to deteriorated clinical signs and poor prognosis, undifferentiated pulmonary adenocarcinoma was diagnosed through histopathologic and immunochemistry examination. To the best of the authors’ knowledge, this is the first study of CT and PET-CT features of canine pulmonary adenocarcinoma. In this case, multiple pulmonary adenocarcinoma could be determined on the basis of FDG PET-CT through screening the obvious distant metastasis and/or lymph node invasions and excluding unknown primary tumors. PMID:24389742

  2. CT paging arteriography with a multidetector-row CT. Advantages in splanchnic arterial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Seiji [Keio Univ., Tokyo (Japan). School of Medicine

    1999-11-01

    The purpose of this study is to assess the utility of CT paging arteriography with a multidetector-row CT as a replacement for conventional angiography in the evaluation of splanchnic arterial anomalies. Sixty-three patients underwent CT paging arteriography with a multidetector-row CT. In the 56 patients with conventional angiographic correlation, there was only one minor disagreement with CT paging arteriography. In the 7 patients who underwent IVDSA (intra venous digital subtraction angiography), CT paging arteriography defined four hepatic arterial anomalies which could not be depicted by IVDSA. In conclusion, CT paging arteriography provides noninvasive means to identify splanchnic arterial anomalies. (author)

  3. Low-dose non-enhanced CT versus full-dose contrast-enhanced CT in integrated PET/CT studies for the diagnosis of uterine cancer recurrence

    Energy Technology Data Exchange (ETDEWEB)

    Kitajima, Kazuhiro [Institute of Biomedical Research and Innovation, Department of PET Diagnosis, Kobe (Japan); Kobe University Graduate School of Medicine, Department of Radiology, Kobe (Japan); Suzuki, Kayo [Institute of Biomedical Research and Innovation, Department of PET Diagnosis, Kobe (Japan); Nakamoto, Yuji [Kyoto University Hospital, Department of Diagnostic Radiology, Kyoto (Japan); Onishi, Yumiko; Sakamoto, Setsu; Sugimura, Kazuro [Kobe University Graduate School of Medicine, Department of Radiology, Kobe (Japan); Senda, Michio [Institute of Biomedical Research and Innovation, Department of Molecular Imaging, Kobe (Japan); Kita, Masato [Kobe City Medical Center General Hospital, Department of Obstetrics and Gynecology, Kobe (Japan)

    2010-08-15

    To evaluate low-dose non-enhanced CT (ldCT) and full-dose contrast-enhanced CT (ceCT) in integrated {sup 18}F-fluorodeoxyglucose (FDG) PET/CT studies for restaging of uterine cancer. A group of 100 women who had undergone treatment for uterine cervical (n=55) or endometrial cancer (n=45) underwent a conventional PET/CT scans with ldCT, and then a ceCT scan. Two observers retrospectively reviewed and interpreted the PET/ldCT and PET/ceCT images in consensus using a three-point grading scale (negative, equivocal, or positive) per patient and per lesion. Final diagnoses were obtained by histopathological examination, or clinical follow-up for at least 6 months. Patient-based analysis showed that the sensitivity, specificity and accuracy of PET/ceCT were 90% (27/30), 97% (68/70) and 95% (95/100), respectively, whereas those of PET/ldCT were 83% (25/30), 94% (66/70) and 91% (91/100), respectively. Sensitivity, specificity and accuracy did not significantly differ between two methods (McNemar test, p=0.48, p=0.48, and p=0.13, respectively). There were 52 sites of lesion recurrence: 12 pelvic lymph node (LN), 11 local recurrence, 8 peritoneum, 7 abdominal LN, 5 lung, 3 supraclavicular LN, 3 liver, 2 mediastinal LN, and 1 muscle and bone. The grading results for the 52 sites of recurrence were: negative 5, equivocal 0 and positive 47 for PET/ceCT, and negative 5, equivocal 4 and positive 43 for PET/ldCT, respectively. Four equivocal regions by PET/ldCT (local recurrence, pelvic LN metastasis, liver metastasis and muscle metastasis) were correctly interpreted as positive by PET/ceCT. PET/ceCT is an accurate imaging modality for the assessment of uterine cancer recurrence. Its use reduces the frequency of equivocal interpretations. (orig.)

  4. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses ... CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known ...

  5. Spinal CT scan, 1

    International Nuclear Information System (INIS)

    Nakagawa, Hiroshi

    1982-01-01

    Methods of CT of the cervical and thoracic spines were explained, and normal CT pictures of them were described. Spinal CT was evaluated in comparison with other methods in various spinal diseases. Plain CT revealed stenosis due to spondylosis or ossification of posterior longitudinal ligament and hernia of intervertebral disc. CT took an important role in the diagnosis of spinal cord tumors with calcification and destruction of the bone. CT scan in combination with other methods was also useful for the diagnosis of spinal injuries, congenital anomalies and infections. (Ueda, J.)

  6. New ultrasonographic evaluation of stool and/or gas distribution for treatment of chronic constipation.

    Science.gov (United States)

    Manabe, Noriaki; Kamada, Tomoari; Hata, Jiro; Haruma, Ken

    2018-03-01

    The first aim of this study was to develop a new ultrasonographic method (US) to evaluate stool and/or gas distribution. The second aim was to apply this method to compare stool and/or gas distribution between healthy subjects and patients with chronic constipation and evaluate whether US parameters could be an alternative to the colonic transit time (CTT). We enrolled seven healthy volunteers (four men, three women; mean age 29.3 ± 5.2 years) who underwent US and computed tomography (CT) on the same day to evaluate the reproducibility of US results. We then enrolled 268 patients with chronic constipation (94 men, 174 women; mean age 63.3 ± 4.2 years) and 66 age- and sex-matched healthy subjects (controls). The transverse diameters of four segments of the colon [ascending (AC), transverse (TC), descending (DC), and sigmoid (SC)] and the rectum (R) were measured, and their stool and/or gas distribution was evaluated using the constipation index (CI) [AC + TC + DC + SC + R/5] and left/right (L/R) distribution [(DC + SC)/(AC + TC)]. The CTT was assessed using radiopaque markers. All healthy subjects underwent US and CT successfully, with a sufficiently high reproducibility coefficient for this method and significant correlation between the US and CT parameters. The stool and/or gas distribution evaluated by US showed a significant difference in one of the US parameters between healthy subjects and patients, and the CI was an indirect indicator for the CTT. These findings may assist physicians evaluate stool and/or gas distribution of patients with chronic constipation, which is an indirect indicator for CTT.

  7. Optimization of Protocol CT, PET-CT, whole body

    International Nuclear Information System (INIS)

    Gutierrez, Fredys Santos; Namias, Mauro

    2013-01-01

    The objective of this study was to optimize the acquisition protocols and processing existing of the CT PET/CT scanner for clinical use of Nuclear Diagnostic Center Foundation, a way to minimize the radiation dose while maintaining diagnostic image quality properly. Dosimetric data of PET / CT service were surveyed and obtained the baseline against which we compare and define strategies and modifications to develop online. We selected transaxial up to the pulmonary hilum and liver slices as the anatomical regions of interest that led to the standardization of the study

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  9. Usefulness of multi-plane dynamic subtraction CT (MPDS-CT) for intracranial high density lesions

    Energy Technology Data Exchange (ETDEWEB)

    Takagi, Ryo; Kumazaki, Tatsuo [Nippon Medical School, Tokyo (Japan)

    1996-02-01

    We present a new CT technique using the high speed CT scanner in detection and evaluation of temporal and spatial contrast enhancement of intracranial high density lesions. A multi-plane dynamic subtraction CT (MPDS-CT) was performed in 21 patients with intracranial high density lesions. These lesions consisted of 10 brain tumors, 7 intracerebral hemorrhages and 4 vascular malformations (2 untreated, 2 post-embolization). Baseline study was first performed, and 5 sequential planes of covering total high density lesions were selected. After obtaining the 5 sequential CT images as mask images, three series of multi-plane dynamic CT were performed for the same 5 planes with an intravenous bolus injection of contrast medium. MPDS-CT images were reconstructed by subtracting dynamic CT images from the mask ones. MPDS-CT were compared with conventional contrast-enhanced CT. MPDS-CT images showed the definite contrast enhancement of high density brain tumors and vascular malformations which were not clearly identified on conventional contrast-enhanced CT images because of calcified or hemorrhagic lesions and embolic materials, enabling us to eliminate enhanced abnormalities with non-enhanced areas such as unusual intracerebral hemorrhages. MPDS-CT will provide us further accurate and objective information and will be greatly helpful for interpreting pathophysiologic condition. (author).

  10. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Abdomen and Pelvis Computed tomography (CT) of the abdomen and pelvis is a ... is CT Scanning of the Abdomen/Pelvis? Computed tomography, more commonly known as a CT or CAT ...

  11. Radiation exposure during CT-guided biopsies: recent CT machines provide markedly lower doses.

    Science.gov (United States)

    Guberina, Nika; Forsting, Michael; Ringelstein, Adrian; Suntharalingam, Saravanabavaan; Nassenstein, Kai; Theysohn, Jens; Wetter, Axel

    2018-03-28

    To examine radiation dose levels of CT-guided interventional procedures of chest, abdomen, spine and extremities on different CT-scanner generations at a large multicentre institute. 1,219 CT-guided interventional biopsies of different organ regions ((A) abdomen (n=516), (B) chest (n=528), (C) spine (n=134) and (D) extremities (n=41)) on different CT-scanners ((I) SOMATOM-Definition-AS+, (II) Volume-Zoom, (III) Emotion6) were included from 2013-2016. Important CT-parameters and standard dose-descriptors were retrospectively examined. Additionally, effective dose and organ doses were calculated using Monte-Carlo simulation, following ICRP103. Overall, radiation doses for CT interventions are highly dependent on CT-scanner generation: the newer the CT scanner, the lower the radiation dose imparted to patients. Mean effective doses for each of four procedures on available scanners are: (A) (I) 9.3mSv versus (II) 13.9mSv (B) (I) 7.3mSv versus (III) 11.4mSv (C) (I) 6.3mSv versus (II) 7.4mSv (D) (I) 4.3mSv versus (II) 10.8mSv. Standard dose descriptors [standard deviation (SD); CT dose index vol (CTDI vol ); dose-length product (DLP body ); size-specific dose estimate (SSDE)] were also compared. Effective dose, organ doses and SSDE for various CT-guided interventional biopsies on different CT-scanner generations following recommendations of the ICRP103 are provided. New CT-scanner generations involve markedly lower radiation doses versus older devices. • Effective dose, organ dose and SSDE are provided for CT-guided interventional examinations. • These data allow identifying organs at risk of higher radiation dose. • Detailed knowledge of radiation dose may contribute to a better individual risk-stratification. • New CT-scanner generations involve markedly lower radiation doses compared to older devices.

  12. Diagnosis of tracheal instability: inspiratory and expiratory spiral CT and cine CT

    International Nuclear Information System (INIS)

    Heussel, C.P.; Thelen, M.; Kauczor, H.U.; Hafner, B.; Lill, J.

    2000-01-01

    Purpose: In tracheo- and bronchomalacia, localization and determination of collapse is necessary for planning a surgical procedure. We compared inspiratory and spiral CT, cine CT, and bronchoscopy and evaluated the relevance of each method. Methods: Seventeen patients with suspected or verified tracheal stonosis or collapse underwent paired inspiratory and exspiratory spiral CT and cine CT during continuous respiration (temporal increment 100 ms). The tracheal cross-sectional area was calculated and compared. Results: In addition to bronchoscopy, further information concerning localization, extent, collapse, stability of the tracheal wall, distal portions of the stenosis, and extraluminal compressions was obtained. A significantly higher degree of tracheal collapse was seen using cine CT compared to paired spiral CT (p [de

  13. Implications of CT noise and artifacts for quantitative 99mTc SPECT/CT imaging

    International Nuclear Information System (INIS)

    Hulme, K. W.; Kappadath, S. C.

    2014-01-01

    Purpose: This paper evaluates the effects of computed tomography (CT) image noise and artifacts on quantitative single-photon emission computed-tomography (SPECT) imaging, with the aim of establishing an appropriate range of CT acquisition parameters for low-dose protocols with respect to accurate SPECT attenuation correction (AC). Methods: SPECT images of two geometric and one anthropomorphic phantom were reconstructed iteratively using CT scans acquired at a range of dose levels (CTDI vol = 0.4 to 46 mGy). Resultant SPECT image quality was evaluated by comparing mean signal, background noise, and artifacts to SPECT images reconstructed using the highest dose CT for AC. Noise injection was performed on linear-attenuation (μ) maps to determine the CT noise threshold for accurate AC. Results: High levels of CT noise (σ ∼ 200–400 HU) resulted in low μ-maps noise (σ ∼ 1%–3%). Noise levels greater than ∼10% in 140 keV μ-maps were required to produce visibly perceptible increases of ∼15% in 99m Tc SPECT images. These noise levels would be achieved at low CT dose levels (CTDI vol = 4 μGy) that are over 2 orders of magnitude lower than the minimum dose for diagnostic CT scanners. CT noise could also lower (bias) the expected μ values. The relative error in reconstructed SPECT signal trended linearly with the relative shift in μ. SPECT signal was, on average, underestimated in regions corresponding with beam-hardening artifacts in CT images. Any process that has the potential to change the CT number of a region by ∼100 HU (e.g., misregistration between CT images and SPECT images due to motion, the presence of contrast in CT images) could introduce errors in μ 140 keV on the order of 10%, that in turn, could introduce errors on the order of ∼10% into the reconstructed 99m Tc SPECT image. Conclusions: The impact of CT noise on SPECT noise was demonstrated to be negligible for clinically achievable CT parameters. Because CT dose levels that affect

  14. Association between spirometry controlled chest CT scores using computer-animated biofeedback and clinical markers of lung disease in children with cystic fibrosis

    DEFF Research Database (Denmark)

    Kongstad, Thomas; Green, Kent; Buchvald, Frederik

    2017-01-01

    Background: Computed tomography (CT) of the lungs is the gold standard for assessing the extent of structural changes in the lungs. Spirometry-controlled chest CT (SCCCT) has improved the usefulness of CT by standardising inspiratory and expiratory lung volumes during imaging. This was a single...... (expressed as % of maximum score) to quantify different aspects of structural lung changes including bronchiectasis, airway wall thickening, mucus plugging, opacities, cysts, bullae and gas trapping. Clinical markers consisted of outcomes from pulmonary function tests, microbiological cultures from sputum......-centre cross-sectional study in children with cystic fibrosis (CF). Using SCCCT we wished to investigate the association between the quantity and extent of structural lung changes and pulmonary function outcomes, and prevalence of known CF lung pathogens. Methods: CT images were analysed by CF-CT scoring...

  15. Performance evaluation of the General Electric eXplore CT 120 micro-CT using the vmCT phantom

    Energy Technology Data Exchange (ETDEWEB)

    Bahri, M.A., E-mail: M.Bahri@ulg.ac.be [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); Warnock, G.; Plenevaux, A. [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); Choquet, P.; Constantinesco, A. [Biophysique et Medecine Nucleaire, Hopitaux universitaires de Strasbourg, Strasbourg (France); Salmon, E.; Luxen, A. [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); Seret, A. [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); ULg-Liege University, Experimental Medical Imaging, Liege (Belgium)

    2011-08-21

    The eXplore CT 120 is the latest generation micro-CT from General Electric. It is equipped with a high-power tube and a flat-panel detector. It allows high resolution and high contrast fast CT scanning of small animals. The aim of this study was to compare the performance of the eXplore CT 120 with that of the eXplore Ultra, its predecessor for which the methodology using the vmCT phantom has already been described . The phantom was imaged using typical a rat (fast scan or F) or mouse (in vivo bone scan or H) scanning protocols. With the slanted edge method, a 10% modulation transfer function (MTF) was observed at 4.4 (F) and 3.9-4.4 (H) mm{sup -1} corresponding to 114 {mu}m resolution. A fairly larger MTF was obtained by the coil method with the MTF for the thinnest coil (3.3 mm{sup -1}) equal to 0.32 (F) and 0.34 (H). The geometric accuracy was better than 0.3%. There was a highly linear (R{sup 2}>0.999) relationship between measured and expected CT numbers for both the CT number accuracy and linearity sections of the phantom. A cupping effect was clearly seen on the uniform slices and the uniformity-to-noise ratio ranged from 0.52 (F) to 0.89 (H). The air CT number depended on the amount of polycarbonate surrounding the area where it was measured; a difference as high as approximately 200 HU was observed. This hindered the calibration of this scanner in HU. This is likely due to the absence of corrections for beam hardening and scatter in the reconstruction software. However in view of the high linearity of the system, the implementation of these corrections would allow a good quality calibration of the scanner in HU. In conclusion, the eXplore CT 120 achieved a better spatial resolution than the eXplore Ultra (based on previously reported specifications) and future software developments will include beam hardening and scatter corrections that will make the new generation CT scanner even more promising.

  16. Pediatric CT angiography

    International Nuclear Information System (INIS)

    Siegel, M.J.

    2005-01-01

    Advances in CT technology are having profound impact on imaging children and have made CT angiography possible even in neonates. Even with the tiny anatomy of neonates, small volumes of contrast material, and small venous access catheters, successful CT angiography can be performed with attention to detail. Meticulous attention to patient preparation, the proper selection of technical factors, and optimal delivery of contrast material are crucial. Data post-processing and the creation of 3-D reconstructions are also essential in establishing a correct diagnosis. The applications fo CT angiography are different in children than in adults and most applications in children involve assessment of congenital and postoperative vascular and cardiac diseases. The use of CT angiography offers the opportunity to eliminate the long periods of sedation associated with MR and reduce the radiation exposure associated with conventional angiography. Generally, the benefits of CT angiography in children outweigh the risk, namely that of radiation exposure. However, care must still be taken to minimize the radiation exposure. (orig.)

  17. Preoperative 4D CT Localization of Nonlocalizing Parathyroid Adenomas by Ultrasound and SPECT-CT.

    Science.gov (United States)

    Hinson, Andrew M; Lee, David R; Hobbs, Bradley A; Fitzgerald, Ryan T; Bodenner, Donald L; Stack, Brendan C

    2015-11-01

    To evaluate 4-dimensional (4D) computed tomography (CT) for the localization of parathyroid adenomas previously considered nonlocalizing on ultrasound and single-photon emission CT with CT scanning (SPECT-CT). To measure radiation exposure associated with 4D-CT and compared it with SPECT-CT. Case series with chart review. University tertiary hospital. Nineteen adults with primary hyperparathyroidism who underwent preoperative 4D CT from November 2013 through July 2014 after nonlocalizing preoperative ultrasound and technetium-99m SPECT-CT scans. Sensitivity, specificity, predictive values, and accuracy of 4D CT were evaluated. Nineteen patients (16 women and 3 men) were included with a mean age of 66 years (range, 39-80 years). Mean preoperative parathyroid hormone level was 108.5 pg/mL (range, 59.3-220.9 pg/mL), and mean weight of the excised gland was 350 mg (range, 83-797 mg). 4D CT sensitivity and specificity for localization to the patient's correct side of the neck were 84.2% and 81.8%, respectively; accuracy was 82.9%. The sensitivity for localizing adenomas to the correct quadrant was 76.5% and 91.5%, respectively; accuracy was 88.2%. 4D CT radiation exposure was significantly less than the radiation associated with SPECT-CT (13.8 vs 18.4 mSv, P = 0.04). 4D CT localizes parathyroid adenomas with relatively high sensitivity and specificity and allows for the localization of some adenomas not observed on other sestamibi-based scans. 4D CT was also associated with less radiation exposure when compared with SPECT-CT based on our study protocol. 4D CT may be considered as first- or second-line imaging for localizing parathyroid adenomas in the setting of primary hyperparathyroidism. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.

  18. CT and ultrasound in the abdomen and in the retroperitoneal space: Competition or combination

    International Nuclear Information System (INIS)

    Kaick, G. van; Redlich, H.; Lorenz, D.; Kilian, J.

    1979-01-01

    Computerized tomography and sonography are competitive methods only in the intraperitoneal and retroperitoneal space. CT offers a complete cross section of the body whereas sonography is often handicapped by 'shadows' caused by gas and bone. Using contrast media, a more specific orientation is possible in CT. On the other hand, sonography provides better differentiation between solid and fluid, and longitudinal sections are easily available. The diagnostic value of both methods and the advantage of their combination are discussed, based on the experience of 120 combined examination in patients whose illnesses were later established definitely. Computer tomography provides better diagnostic results than echography; the differences, however, are not so great for this to mean a substantial loss of importance for echographic diagnostics. In principle, echography should preceded computerized tomography to save time for CT scanning as well as to reduce the patient's dose. (orig.) 891 MG/orig. 892 MB [de

  19. Coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Dewey, Marc [Charite - Universitaetsmedizin Berlin (Germany). Inst. fuer Radiologie

    2009-07-01

    Coronary CT angiography has attained increasing scientific attention at academic institutions and has become a highly accurate diagnostic modality. Extending this knowledge into a practice setting is the purpose of 'Coronary CT Angiography'. This book will assist you in integrating cardiac CT into your daily practice, while also giving an overview of the current technical status and applications. The specific features of scanners from all four main vendors are also presented providing an objective overview of noninvasive coronary angiography using CT. (orig.)

  20. Correlating Gas Transport Parameters and X-ray Computed Tomography Measurements in Porous Media

    DEFF Research Database (Denmark)

    Naveed, Muhammad; Hamamoto, Shoichiro; Kawamoto, Ken

    2013-01-01

    physical processes. The objective of this study was to characterize the relationships between gas transport parameters and soil-pore geometry revealed by X-ray CT. Sands of different shapes with a mean particle diameter (d50) ranging from 0.19 to 1.51 mm were used as porous media under both air...... was found between α and tortuosity calculated from gas transport parameters (Equation (Uncited) Image Tools), indicating that gas dispersivity has a linear and inverse relationship with gas diffusivity. A linear relationship was also found between ka and d50/TUMS2, indicating a strong dependency of ka...

  1. Indications for chest CT. Retrospective study of cases with normal chest CT

    International Nuclear Information System (INIS)

    Obata, Shiro

    1995-01-01

    The usefulness of computed tomography (CT) in thoracic radiology is now well appreciated, and the number of chest CTs has greatly increased. There are, however, many chest CT cases that are completely or almost completely normal. Indications for chest CT should be re-evaluated considering the cost and radiation exposure associated with the examination. Reviewing the reports of 4930 chest CT examinations performed in three hospitals during the period of two years, the author found 620 (12.6%) negative CT examinations. In 312 of the 620, the CT was requested because of 'abnormal shadow' on chest radiograph. When the same chest radiographs were re-evaluated by two radiologists, no abnormality was noted in 257 cases (82.4%). CT examinations were considered justified in only 55 cases (17.6%). There was a significant difference in the frequency of normal chest CT examinations between the university hospital and two other hospitals. The causes of false positive interpretation of chest radiographs were analyzed, and it was felt that fundamental knowledge necessary to interpret chest radiographs was lacking. The importance of close cooperation between clinicians and radiologists should be emphasized. (author)

  2. Micro-CT and nano-CT analysis of filling quality of three different endodontic sealers.

    Science.gov (United States)

    Huang, Yan; Celikten, Berkan; de Faria Vasconcelos, Karla; Ferreira Pinheiro Nicolielo, Laura; Lippiatt, Nicholas; Buyuksungur, Arda; Jacobs, Reinhilde; Orhan, Kaan

    2017-12-01

    To investigate voids in different root canal sealers using micro-CT and nano-CT, and to explore the feasibility of using nano-CT for quantitative analysis of sealer filling quality. 30 extracted mandibular central incisors were randomly assigned into three groups according to the applied root canal sealers (Total BC Sealer, Sure Seal Root, AH Plus) by the single cone technique. Subsequently, micro-CT and nano-CT were performed to analyse the incidence rate of voids, void fraction, void volume and their distribution in each sample. Micro-CT evaluation showed no significant difference among sealers for the incidence rate of voids or void fraction in the whole filling materials (p > 0.05), whereas a significant difference was found between AH Plus and the other two sealers using nano-CT (p nano-CT results displayed higher void volume in AH Plus among all the sealers and regions (p nano-CT analysis, when round root canals were treated by the single cone technique. The disparate results suggest that the higher resolution of nano-CT have a greater ability of distinguishing internal porosity, and therefore suggesting the potential use of nano-CT in quantitative analysis of filling quality of sealers.

  3. Xenon-enhanced CT using subtraction CT: Basic and preliminary clinical studies for comparison of its efficacy with that of dual-energy CT and ventilation SPECT/CT to assess regional ventilation and pulmonary functional loss in smokers

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Yoshikawa, Takeshi; Takenaka, Daisuke; Fujisawa, Yasuko; Sugihara, Naoki; Kishida, Yuji; Seki, Shinichiro; Koyama, Hisanobu; Sugimura, Kazuro

    2017-01-01

    Purpose: To prospectively and directly compare the capability for assessments of regional ventilation and pulmonary functional loss in smokers of xenon-ventilation CT obtained with the dual-energy CT (DE-CT) and subtraction CT (Sub-CT) Materials and methods: Twenty-three consecutive smokers (15 men and 8 women, mean age: 69.7 ± 8.7 years) underwent prospective unenhanced and xenon-enhanced CTs, the latter by Sub-CT and DE-CT methods, ventilation SPECT and pulmonary function tests. Sub-CT was generated from unenhanced and xenon-enhanced CT, and all co-registered SPECT/CT data were produced from SPECT and unenhanced CT data. For each method, regional ventilation was assessed by using a 11-point scoring system on a per-lobe basis. To determine the functional lung volume by each method, it was also calculated for individual sublets with a previously reported method. To determine inter-observer agreement for each method, ventilation defect assessment was evaluated by using the χ2 test with weighted kappa statistics. For evaluation of the efficacy of each method for pulmonary functional loss assessment, functional lung volume was correlated with%FEV 1 . Results: Each inter-observer agreement was rated as substantial (Sub-CT: κ = 0.69, p < 0.0001; DE-CT: κ = 0.64, p < 0.0001; SPECT/CT: κ = 0.64, p < 0.0001). Functional lung volume for each method showed significant to good correlation with%FEV 1 (Sub-CT: r = 0.72, p = 0.0001; DE-CT: r = 0.74, p < 0.0001; SPECT/CT: r = 0.66, p = 0.0006). Conclusion: Xenon-enhanced CT obtained by Sub-CT can be considered at least as efficacious as that obtained by DE-CT and SPECT/CT for assessment of ventilation abnormality and pulmonary functional loss in smokers.

  4. Xenon-enhanced CT using subtraction CT: Basic and preliminary clinical studies for comparison of its efficacy with that of dual-energy CT and ventilation SPECT/CT to assess regional ventilation and pulmonary functional loss in smokers

    Energy Technology Data Exchange (ETDEWEB)

    Ohno, Yoshiharu, E-mail: yosirad@kobe-u.ac.jp [Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe (Japan); Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe (Japan); Yoshikawa, Takeshi [Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe (Japan); Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe (Japan); Takenaka, Daisuke [Department of Radiology, Hyogo Cancer Center, Akashi (Japan); Fujisawa, Yasuko; Sugihara, Naoki [Toshiba Medical Systems Corporation, Otawara (Japan); Kishida, Yuji; Seki, Shinichiro; Koyama, Hisanobu; Sugimura, Kazuro [Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine (Japan)

    2017-01-15

    Purpose: To prospectively and directly compare the capability for assessments of regional ventilation and pulmonary functional loss in smokers of xenon-ventilation CT obtained with the dual-energy CT (DE-CT) and subtraction CT (Sub-CT) Materials and methods: Twenty-three consecutive smokers (15 men and 8 women, mean age: 69.7 ± 8.7 years) underwent prospective unenhanced and xenon-enhanced CTs, the latter by Sub-CT and DE-CT methods, ventilation SPECT and pulmonary function tests. Sub-CT was generated from unenhanced and xenon-enhanced CT, and all co-registered SPECT/CT data were produced from SPECT and unenhanced CT data. For each method, regional ventilation was assessed by using a 11-point scoring system on a per-lobe basis. To determine the functional lung volume by each method, it was also calculated for individual sublets with a previously reported method. To determine inter-observer agreement for each method, ventilation defect assessment was evaluated by using the χ2 test with weighted kappa statistics. For evaluation of the efficacy of each method for pulmonary functional loss assessment, functional lung volume was correlated with%FEV{sub 1}. Results: Each inter-observer agreement was rated as substantial (Sub-CT: κ = 0.69, p < 0.0001; DE-CT: κ = 0.64, p < 0.0001; SPECT/CT: κ = 0.64, p < 0.0001). Functional lung volume for each method showed significant to good correlation with%FEV{sub 1} (Sub-CT: r = 0.72, p = 0.0001; DE-CT: r = 0.74, p < 0.0001; SPECT/CT: r = 0.66, p = 0.0006). Conclusion: Xenon-enhanced CT obtained by Sub-CT can be considered at least as efficacious as that obtained by DE-CT and SPECT/CT for assessment of ventilation abnormality and pulmonary functional loss in smokers.

  5. Multiscale CT-Based Computational Modeling of Alveolar Gas Exchange during Artificial Lung Ventilation, Cluster (Biot and Periodic (Cheyne-Stokes Breathings and Bronchial Asthma Attack

    Directory of Open Access Journals (Sweden)

    Andrey Golov

    2017-02-01

    Full Text Available An airflow in the first four generations of the tracheobronchial tree was simulated by the 1D model of incompressible fluid flow through the network of the elastic tubes coupled with 0D models of lumped alveolar components, which aggregates parts of the alveolar volume and smaller airways, extended with convective transport model throughout the lung and alveolar components which were combined with the model of oxygen and carbon dioxide transport between the alveolar volume and the averaged blood compartment during pathological respiratory conditions. The novel features of this work are 1D reconstruction of the tracheobronchial tree structure on the basis of 3D segmentation of the computed tomography (CT data; 1D−0D coupling of the models of 1D bronchial tube and 0D alveolar components; and the alveolar gas exchange model. The results of our simulations include mechanical ventilation, breathing patterns of severely ill patients with the cluster (Biot and periodic (Cheyne-Stokes respirations and bronchial asthma attack. The suitability of the proposed mathematical model was validated. Carbon dioxide elimination efficiency was analyzed in all these cases. In the future, these results might be integrated into research and practical studies aimed to design cyberbiological systems for remote real-time monitoring, classification, prediction of breathing patterns and alveolar gas exchange for patients with breathing problems.

  6. Non-enhanced CT versus contrast-enhanced CT in integrated PET/CT studies for nodal staging of rectal cancer

    International Nuclear Information System (INIS)

    Tateishi, Ukihide; Maeda, Tetsuo; Morimoto, Tsuyoshi; Miyake, Mototaka; Arai, Yasuaki; Kim, E.E.

    2007-01-01

    The purpose of the present study was to determine the diagnostic accuracy of non-enhanced CT and contrast-enhanced CT in integrated PET/CT studies for preoperative nodal staging of rectal cancer. Retrospective analysis was performed in 53 patients with pathologically proven rectal cancer who had been referred for preoperative staging. All patients underwent integrated PET/CT consisting of non-enhanced and contrast-enhanced CT followed by whole-body fluorine-18-fluorodeoxyglucose ([ 18 F]FDG) PET. Both non-enhanced and contrast-enhanced PET/CT images were evaluated separately by two observers in consensus. The reference standard was histopathologic results. For nodal staging of rectal cancer, we compared diagnostic accuracy on a per-patient basis between the two modalities. Nodal staging was correctly determined with non-enhanced studies in 37 patients (70%) and with contrast-enhanced studies in 42 patients (79%). On a per-patient basis, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of regional lymph node staging were 85%, 68%, 83%, 72%, and 79%, respectively, with contrast-enhanced studies, and 85%, 42%, 73%, 62%, and 70%, respectively, with non-enhanced studies. The difference in the accuracy of nodal staging between the two modalities was not significant (p = 0.063). Compared with non-enhanced studies, contrast-enhanced studies determined more correctly the status of pararectal lymph nodes (p 0.002), internal iliac lymph nodes (p = 0.004), and obturator lymph nodes (p < 0.0001). Contrast-enhanced PET/CT is superior to non-enhanced PET/CT for precise definition of regional nodal status in rectal cancer. (orig.)

  7. Blunt trauma to the gastrointestinal tract and mesentery: is there a role for helical CT in the decision-making process?

    International Nuclear Information System (INIS)

    Scaglione, Mariano; de Lutio di Castelguidone, Elisabetta; Scialpi, Michele; Merola, Stefanella; Diettrich, Andrea Irma; Lombardo, Patrizia; Romano, Luigia; Grassi, Roberto

    2004-01-01

    The CT diagnosis of bowel and mesenteric injuries is difficult and warrants optimal technique and skilled interpretation. We retrospectively reviewed 36 consecutive patients with blunt traumatic injuries to the bowel and mesentery at our regional level I trauma center during the past 3 years. Physical examination, laboratory, Computed tomographic (CT), and intraoperative findings were compared. Surgically proven bowel injuries (13 cases) occurred in the duodenum (three cases), ileum (two cases), jejunum (two cases), colon (three cases), and stomach (three cases). CT findings considered specific of bowel rupture were observed in 5/13 patients including: extraluminal oral contrast or luminal content extravasation (four cases) and discontinuity of hollow viscus wall (one case). In the remaining 8/13 CT findings considered suggestive of bowel injury consisted of: pneumoperitoneum (six), gas bubbles close to the injured hollow viscus (three), thickened (>4-5 mm) bowel wall (five), bowel wall hematoma (three), intraperitoneal fluid of unknown source (three). Mesenteric injury (23 cases) were surgically observed at the level of the mesenteric vessels (17 cases), legament of Treitz (two cases), gastro-duodenal artery (one case), transverse (one case) and sigmoid mesocolon (one case). CT finding considered specific of mesenteric laceration was active extravasation of contrast material from the mesenteric vessels (10 cases). CT findings suggestive of mesenteric injury (13 cases) consisted of: mesenteric hematoma (five) and/or high attenuation fluid collections, within the mesenteric root (eight) and folds (four). Helical CT is sensitive in the identification of bowel and mesenteric injury after blunt trauma providing a wide spectrum of findings. However, CT cannot be used as the sole indicator in cases with isolated thickened bowel wall, mesenteric hematoma, bowel hematoma, pneumoperitoneum or gas bubbles. Persistent, active extravasation of intravenous contrast medium from

  8. Whole-body CT. Spiral and multislice CT. 2. tot. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Prokop, M.; Galanski, M.; Schaefer-Prokop, C.; Molen, A.J. van der

    2007-01-01

    Spiral and multidetector techniques have improved the diagnostic possibilities of CT, so that image analysis and interpretation have become increasingly complex. This book represents the current state of the art in CT imaging, including the most recent technical scanner developments. The second edition comprises the current state of knowledge in cT imaging. There are new chapters on image processing, application of contrasting agents and radiation dose. All organ-specific pathological findings are discussed in full. There are hints for optimum use and interpretation of CT, including CT angiography, CT colonography, CT-IVPL, and 3D imaging. There is an introduction to cardio-CT, from calcium scoring and CTA of the coronary arteries to judgement of cardiac morphology. There are detailed scan protocols with descriptions of how to go about parameter selection. Practical hints are given for better image quality and lower radiation exposure of patients, guidelines for patient preparation and complication management, and more than 1900 images in optimum RRR quality. (orig.)

  9. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses ... of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  10. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses special ... the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  11. Perfusion CT in acute stroke

    International Nuclear Information System (INIS)

    Eckert, Bernd; Roether, Joachim; Fiehler, Jens; Thomalla, Goetz

    2015-01-01

    Modern multislice CT scanners enable multimodal protocols including non-enhanced CT, CT angiography, and CT perfusion. A 64-slice CT scanner provides 4-cm coverage. To cover the whole brain, a 128 - 256-slice scanner is needed. The use of perfusion CT requires an optimized scan protocol in order to reduce exposure to radiation. As compared to non-enhanced CT and CT angiography, the use of CT perfusion increases detection rates of cerebral ischemia, especially small cortical ischemic lesions, while the detection of lacunar and infratentorial stroke lesions remains limited. Perfusion CT enables estimation of collateral flow in acute occlusion of large intra- or extracranial arteries. Currently, no established reliable thresholds are available for determining infarct core and penumbral tissue by CT perfusion. Moreover, perfusion parameters depend on the processing algorithms and the software used for calculation. However, a number of studies point towards a reduction of cerebral blood volume (CBV) below 2 ml/100 g as a critical threshold that identifies infarct core. Large CBV lesions are associated with poor outcome even in the context of recanalization. The extent of early ischemic signs on non-enhanced CT remains the main parameter from CT imaging to guide acute reperfusion treatment. Nevertheless, perfusion CT increases diagnostic and therapeutic certainty in the acute setting. Similar to stroke MRI, perfusion CT enables the identification of tissue at risk of infarction by the mismatch between infarct core and the larger area of critical hypoperfusion. Further insights into the validity of perfusion parameters are expected from ongoing trials of mechanical thrombectomy in stroke.

  12. Spiral CT versus conventional CT in the preoperative assessment of metallic intraocular foreign bodies

    International Nuclear Information System (INIS)

    Prokesch, R.; Bankier, A.; Ba-Ssalamah, A.; Imhof, H.; Lakits, A.; Scholda, C.

    1998-01-01

    Purpose: To compare the effectiveness of spiral CT versus conventional CT in the preoperative assessment of metallic intraocular foreign bodies. Results: All foreign bodies were detected by each scanning modality on the axial and on the reconstructed planes. The quality of the axial images was similar for spiral and conventional CT. The spiral technique provided high-quality reconstructed images which allowed accurate localization of the foreign bodies in all cases. Reconstructions by conventional technique were inadequate for preoperative assessment. The examination time for the total orbital volume was 18 s for spiral CT and 52 s for conventional CT. Radiation dose delivered to the lens was 35 mGy for spiral CT and 56 mGy for conventional CT axial scanning. Conclusion: Spiral CT multiplanar offers several significant advantages for the preoperative assessment of metallic intraocular foreign bodies compared to the conventional CT technique in clinical practice, including short examination time, minimized motion artifacts, reduced radiation exposure, and accurate localization. (orig.) [de

  13. Technical Note: Precise quantitative measurements of total dissolved inorganic carbon from small amounts of seawater using a gas chromatographic system

    Directory of Open Access Journals (Sweden)

    T. Hansen

    2013-10-01

    Full Text Available Total dissolved inorganic carbon (CT is one of the most frequently measured parameters used to calculate the partial pressure of carbon dioxide in seawater. Its determination has become increasingly important because of the rising interest in the biological effects of ocean acidification. Coulometric and infrared detection methods are currently favored in order to precisely quantify CT. These methods however are not sufficiently validated for CT measurements of biological experiments manipulating seawater carbonate chemistry with an extended CT measurement range (~1250–2400 μmol kg–1 compared to natural open ocean seawater (~1950–2200 μmol kg−1. The requirement of total sample amounts between 0.1–1 L seawater in the coulometric- and infrared detection methods potentially exclude their use for experiments working with much smaller volumes. Additionally, precise CT analytics become difficult with high amounts of biomass (e.g., phytoplankton cultures or even impossible in the presence of planktonic calcifiers without sample pre-filtration. Filtration however, can alter CT concentration through gas exchange induced by high pressure. Addressing these problems, we present precise quantification of CT using a small, basic and inexpensive gas chromatograph as a CT analyzer. Our technique is able to provide a repeatability of ±3.1 μmol kg−1, given by the pooled standard deviation over a CT range typically applied in acidification experiments. 200 μL of sample is required to perform the actual CT measurement. The total sample amount needed is 12 mL. Moreover, we show that sample filtration is applicable with only minor alteration of the CT. The method is simple, reliable and with low cumulative material costs. Hence, it is potentially attractive for all researchers experimentally manipulating the seawater carbonate system.

  14. Chiyoda Thoroughbred CT-121 clean coal project at Georgia Power`s Plant Yates

    Energy Technology Data Exchange (ETDEWEB)

    Burford, D.P. [Southern Company Services, Inc., Birmingham, AL (United States)

    1997-12-31

    The Chiyoda Thoroughbred CT-121 flue gas desulfurization (FGD) process at Georgia Power`s Plant Yates completed a two year demonstration of its capabilities in late 1994 under both high- and low-particulate loading conditions. This $43 million demonstration was co-funded by Southern Company, the Electric Power Research Institute and the DOE under the auspices of the US Department of Energy`s Round II Innovative Clean Coal Technology (ICCT) program. The focus of the Yates Project was to demonstrate several cost-saving modifications to Chiyoda`s already efficient CT-121 process. These modifications included: the extensive use of fiberglass reinforced plastics (FRP) in the construction of the scrubber vessel and other associated vessels, the elimination of flue gas reheat through the use of an FRP wet chimney, and reliable operation without a spare absorber module. This paper focuses on the testing results from the last trimester of the second phase of testing (high-ash loading). Specifically, operation under elevated ash loading conditions, the effects of low- and high-sulfur coal, air toxics verification testing results and unexpected improvements in byproduct gypsum quality are discussed.

  15. CT and MR imaging of the kidney and adrenal glands: CT of the kidney

    International Nuclear Information System (INIS)

    Levine, E.

    1987-01-01

    Because of its high diagnostic yield, safety, and cost-effectiveness, CT has become a major imaging technique for evaluating the kidney. CT is highly accurate for determining the nature and extent of renal masses, and this has become the main indication for renal CT. However, CT is also valuable in assessing patients with renal cystic disease, trauma, inflammatory disease, infarction, hemorrhage and hydronephrosis of unknown cause. This presentation reviews the normal CT anatomy of the kidneys and the usefulness of CT in the diagnosis of all these conditions. Examination techniques are discussed with particular emphasis on avoiding diagnostic pitfalls and tailoring the examination to the nature of the clinical problem. CT findings in various renal disorders are compared with those of other imaging techniques, particularly US and angiography, and the place of CT in the diagnostic approach to these disorders is considered

  16. The role of computer tomography in the diagnosis of arterial gas embolism in fatal diving accidents in Tasmania

    International Nuclear Information System (INIS)

    Oliver, J.; Lyons, T.J.; Harle, R.

    1999-01-01

    Four cases of fatal diving accidents in Tasmania are presented, highlighting the role of CT in the investigation of diving fatalities. The CT technique allows rapid diagnosis when arterial gas embolism (AGE) is suspected. The traditional method of investigation, underwater autopsy, is a difficult procedure that requires specialized training in which the subtle diagnosis of AGE may be completely missed. Facilities for performing underwater autopsies are normally available only in tertiary referral centres, and therefore the diagnosis of AGE may be missed due to lack of facilities. The use of CT in the diagnosis of AGE in divers was first utilized in the early 1980s but has still not become widely adopted in forensic practice. This radiological technique has the advantage of being sensitive, quick, reliable, readily available and provides a permanent record. For hospitals that do not have a resident forensic pathologist, a CT scan can be easily performed and interpreted to eliminate the possibility of AGE. There are a number of pitfalls in the diagnosis of AGE with CT, particularly intravascular gas production following postmortem fermentation and off-gassing. Awareness of these pitfalls will help the radiologist in making a correct diagnosis of AGE. Copyright (1999) Blackwell Science Pty Ltd

  17. Improved attenuation correction for respiratory gated PET/CT with extended-duration cine CT: a simulation study

    Science.gov (United States)

    Zhang, Ruoqiao; Alessio, Adam M.; Pierce, Larry A.; Byrd, Darrin W.; Lee, Tzu-Cheng; De Man, Bruno; Kinahan, Paul E.

    2017-03-01

    Due to the wide variability of intra-patient respiratory motion patterns, traditional short-duration cine CT used in respiratory gated PET/CT may be insufficient to match the PET scan data, resulting in suboptimal attenuation correction that eventually compromises the PET quantitative accuracy. Thus, extending the duration of cine CT can be beneficial to address this data mismatch issue. In this work, we propose to use a long-duration cine CT for respiratory gated PET/CT, whose cine acquisition time is ten times longer than a traditional short-duration cine CT. We compare the proposed long-duration cine CT with the traditional short-duration cine CT through numerous phantom simulations with 11 respiratory traces measured during patient PET/CT scans. Experimental results show that, the long-duration cine CT reduces the motion mismatch between PET and CT by 41% and improves the overall reconstruction accuracy by 42% on average, as compared to the traditional short-duration cine CT. The long-duration cine CT also reduces artifacts in PET images caused by misalignment and mismatch between adjacent slices in phase-gated CT images. The improvement in motion matching between PET and CT by extending the cine duration depends on the patient, with potentially greater benefits for patients with irregular breathing patterns or larger diaphragm movements.

  18. A modified VMAT adaptive radiotherapy for nasopharyngeal cancer patients based on CT-CT image fusion

    International Nuclear Information System (INIS)

    Jin, Xiance; Han, Ce; Zhou, Yongqiang; Yi, Jinling; Yan, Huawei; Xie, Congying

    2013-01-01

    To investigate the feasibility and benefits of a modified adaptive radiotherapy (ART) by replanning in the initial CT (iCT) with new contours from a repeat CT (rCT) based on CT-CT image fusion for nasopharyngeal cancer (NPC) patients underwent volumetric modulated arc radiotherapy (VMAT). Nine NPC patients underwent VMAT treatment with a rCT at 23rd fraction were enrolled in this study. Dosimetric differences for replanning VMAT plans in the iCT and in the rCT were compared. Volumetric and dosimetric changes of gross tumor volume (GTV) and organs at risk (OARs) of this modified ART were also investigated. No dosimetric differences between replanning in the iCT and in the rCT were observed. The average volume of GTV decreased from 78.83 ± 38.42 cm 3 in the iCT to 71.44 ± 37.46 cm 3 in the rCT, but with no significant difference (p = 0.42).The average volume of the left and right parotid decreased from 19.91 ± 4.89 cm 3 and 21.58 ± 6.16 cm 3 in the iCT to 11.80 ± 2.79 cm 3 and 13.29 ± 4.17 cm 3 in the rCT (both p < 0.01), respectively. The volume of other OARs did not shrink very much. No significant differences on PTV GTV and PTV CTV coverage were observed for replanning with this modified ART. Compared to the initial plans, the average mean dose of the left and right parotid after re-optimization were decreased by 62.5 cGy (p = 0.05) and 67.3 cGy (p = 0.02), respectively, and the V5 (the volume receiving 5 Gy) of the left and right parotids were decreased by 7.8% (p = 0.01) and 11.2% (p = 0.001), respectively. There was no significant difference on the dose delivered to other OARs. Patients with NPC undergoing VMAT have significant anatomic and dosimetric changes to parotids. Repeat CT as an anatomic changes reference and re-optimization in the iCT based on CT-CT image fusion was accurate enough to identify the volume changes and to ensure safe dose to parotids

  19. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ...

  20. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ...

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ...

  2. Spiral CT for evaluation of chest trauma; Spiral-CT beim Thoraxtrauma

    Energy Technology Data Exchange (ETDEWEB)

    Roehnert, W. [Universitaetsklinikum Dresden (Germany). Inst. und Poliklinik fuer Radiologische Diagnostik; Weise, R. [Universitaetsklinikum Dresden (Germany). Inst. und Poliklinik fuer Radiologische Diagnostik

    1997-07-01

    After implementation of spiral CT in our department, we carried out an analysis for determining anew the value of CT as a modality of chest trauma diagnosis in the emergency department. The retrospective study covers a period of 10 months and all emergency patients with chest trauma exmined by spiral CT. The major lesions of varying seriousness covered by this study are: pneumothorax, hematothorax, pulmonary contusion or laceration, mediastinal hematoma, rupture of a vessel, injury of the heart and pericardium. The various fractures are not included in this study. In many cases, spiral CT within relatively short time yields significant diagnostic findings, frequently saving additional angiography. A rigid diagnostic procedure cannot be formulated. Plain-film chest radiography still remains a diagnostic modality of high value. (Orig.) [Deutsch] Nach Einfuehrung der Spiral-CT in unserer Einrichtung versuchten wir, den Stellenwert der Computertomographie in der Notfalldiagnostik des Thoraxtraumas neu zu bestimmen. Dazu wurden retrospektiv ueber einen Zeitraum von 10 Monaten alle mittels Spiral-CT untersuchten Notfallpatienten mit Thoraxverletzungen ausgewertet. Im Vordergrund standen folgende Befunde unterschiedlichen Schweregrades: Pneumothorax, Haematothorax, Lungenkontusion/-lazeration, Mediastinalhaematom, Gefaessruptur, Herz- und Herzbeutelverletzung. Auf die unterschiedlichen Frakturen wird bewusst nicht naeher eingegangen. In vielen Faellen liefert die Spiral-CT mit relativ geringem Zeitaufwand wesentliche diagnostische Aussagen. Haeufig kann auf eine Angiographie verzichtet werden. Ein starres diagnostisches Stufenschema laesst sich nicht definieren. Die Thoraxuebersichtsaufnahme besitzt einen unveraendert hohen Stellenwert. (orig.)

  3. Marketing cardiac CT programs.

    Science.gov (United States)

    Scott, Jason

    2010-01-01

    There are two components of cardiac CT discussed in this article: coronary artery calcium scoring (CACS) and coronary computed tomography angiography (CCTA).The distinctive advantages of each CT examination are outlined. In order to ensure a successful cardiac CT program, it is imperative that imaging facilities market their cardiac CT practices effectively in order to gain a competitive advantage in this valuable market share. If patients receive quality care by competent individuals, they are more likely to recommend the facility's cardiac CT program. Satisfied patients will also be more willing to come back for any further testing.

  4. Postoperative CT in pancreas transplantation

    International Nuclear Information System (INIS)

    Powell, F.E.; Harper, S.J.F.; Callaghan, C.J.; Shaw, A.; Godfrey, E.M.; Bradley, J.A.; Watson, C.J.E.; Pettigrew, G.J.

    2015-01-01

    Aim: To examine the usage and value of computed tomography (CT) following simultaneous pancreas and kidney (SPK) transplantation. Materials and methods: Indications for postoperative CT, key findings, and their influence on management were determined by retrospective analysis. Results: Ninety-eight patients underwent 313 CT examinations. Common indications for the examinations included suspected intra-abdominal collection (31.1%) and elevated serum amylase/lipase (24.1%). CT findings most frequently showed non-specific mild inflammation (27.6%), a normal scan (17.1%) and fluid collections (16.3%). High capillary blood glucose (CBG) was associated with resultant CT demonstration of graft vascular abnormalities, but otherwise, particular clinical indications were not associated with specific CT findings. Conclusion: Clinical findings in patients with SPK transplants are non-specific. The pattern of abnormalities encountered is significantly different to those seen in native pancreatic disease and demands a tailored protocol. CT enables accurate depiction of vascular abnormalities and fluid collections, thus reducing the number of surgical interventions that might otherwise be required. Elevated CBG should prompt urgent CT to exclude potentially reversible vascular complications. - Highlights: • The value of CT following simultaneous pancreas and kidney transplantation was assessed. • 313 CT scans were performed on 98 patients between January 2005 and August 2010. • Elevated blood glucose was associated with CT findings of graft vascular anomalities. • CT was particularly useful in directing operative versus non-operative intervention.

  5. Spinal CT scan, 2

    International Nuclear Information System (INIS)

    Nakagawa, Hiroshi

    1982-01-01

    Plain CT described fairly accurately the anatomy and lesions of the lumbar and sacral spines on their transverse sections. Since hernia of the intervertebral disc could be directly diagnosed by CT, indications of myelography could be restricted. Spinal-canal stenosis of the lumbar spine occurs because of various factors, and CT not only demonstrated the accurate size and morphology of bony canals, but also elucidated thickening of the joints and yellow ligament. CT was also useful for the diagnosis of tumors in the lumbar and sacral spines, visualizing the images of bone changes and soft tissues on the trasverse sections. But the diagnosis of intradural tumors required myelography and metrizamide CT. CT has become important for the diagnosis of spinal and spinal-cord diseases and for selection of the route of surgical arrival. (Chiba, N.)

  6. CT manifestations of liver abscess

    International Nuclear Information System (INIS)

    Yan Jianfeng; Peng Yongjun

    2006-01-01

    Objective: To study CT findings of hepatic abscess. Methods: CT findings and clinical materials of 38 patients with liver abscess verified by aspiration were retrospectively viewed. All patients were examined by non-enhanced and contrast enhanced CT. Results: In 25 cases, inhomogeneous hypodense lesions with unclear demarcation were found on non-enhanced CT. On contrast enhanced CT scan, target or cluster enhancement was found Additionally, air was found within some lesions. In the rest 13 cases with early stage liver abscess, no typical sign was found on non-enhanced CT, while rosette sign and continued enhancement sign were demonstrated after the contrast agent was given. Conclusion: Various CT findings are found in different stages of liver abscess. The diagnosis and differential diagnosis should be based on CT manifestations and clinical history as well. (authors)

  7. Pulmonary emphysema quantitation with Computed Tomography. Comparison between the visual score with high resolution CT, expiratory density mask with spiral CT and lung function studies

    International Nuclear Information System (INIS)

    Zompatori, Maurizio; Battaglia, Milva; Rimondi, Maria Rita; Vivacqua, Donatella; Biscarini, Manuela; Fasano, Luca; Pacilli, Angela Maria Grazia; Guerrieri, Aldo; Fabbri, Mario; Cavina, Mauro

    1997-01-01

    CT is the most accurate method to detect pulmonary emphysema in vivo. They compared prospectively two different methods for emphysema quantitation in 5 normal volunteers and 20 consecutive patients with chronic obstructive pulmonary disease (COPD). All subjects were submitted to function tests and HRCT; three scans were acquired at preselected levels during inspiration. The type and extent of pulmonary emphysema were defined by two independent observers under blind conditions. Disagreements were subsequently settled by consent. All subjects were also examined with expiratory spiral CT using a density mask program, at two different cut-off levels (-850,-900 HU). Visual score and expiratory spiral density mask values (-850 HU) were significantly correlated (r = 0.86), but the visual extent of emphysema was always higher than shown by expiratory spiral CT. The emphysema extent assessed with both CT methods correlated with the function result of expiratory airflow obstruction and gas diffusion impairment (visual score versus forced expiratory volume in one second: r = -0.81, versus single breath carbon monoxide diffusion: r = -0.78. Spiral expiratory density mask -850 HU versus forced expiratory volume in one second: r = -0.85 versus single breath carbon monoxide diffusion: r = -0.77). When -900 HU was used as the cut-off value for the expiratory density mask, the correlation with single breath carbon monoxide diffusion worsened (r = -0.56). Visual score and expiratory density mask -850 HU gave similar results and permitted COPD patients to be clearly distinguished from normal controls (p < 0.01). They believe the true residual volume should lie somewhere in between the CT value and the function results with the helium dilution technique and conclude that the extent of pulmonary emphysema can be confidently assessed with CT methods. Finally, the simple visual score may be as reliable as such highly sophisticated new methods as the spiral expiratory density mask

  8. Radiation exposure during paediatric CT in Sudan: CT dose, organ and effective doses

    International Nuclear Information System (INIS)

    Suliman, I.I.; Khamis, H.M.; Ombada, T.H.; Alzimami, K.; Alkhorayef, M.; Sulieman, A.

    2015-01-01

    The purpose of this study was to assess the magnitude of radiation exposure during paediatric CT in Sudanese hospitals. Doses were determined from CT acquisition parameters using CT-Expo 2.1 dosimetry software. Doses were evaluated for three patient ages (0-1, 1-5 and 5-10 y) and two common procedures (head and abdomen). For children aged 0-1 y, volume CT air kerma index (C vol ), air Kerma-length product and effective dose (E) values were 19.1 mGy, 265 mGy.cm and 3.1 mSv, respectively, at head CT and those at abdominal CT were 8.8 mGy, 242 mGy.cm and 7.7 mSv, respectively. Those for children aged 1-5 y were 22.5 mGy, 305 mGy.cm and 1.1 mSv, respectively, at head CT and 12.6 mGy, 317 mGy.cm, and 5.1 mSv, respectively, at abdominal CT. Dose values and variations were comparable with those reported in the literature. Organ equivalent doses vary from 7.5 to 11.6 mSv for testes, from 9.0 to 10.0 mSv for ovaries and from 11.1 to 14.3 mSv for uterus in abdominal CT. The results are useful for dose optimisation and derivation of national diagnostic reference levels. (authors)

  9. CT of the knee

    International Nuclear Information System (INIS)

    Ghelman, B.

    1987-01-01

    CT can be combined with arthrography of the knee to study the following abnormalities: meniscal tears and cysts, synovial plicae, chondromalacia patellae, and osteochondritis dissecans. The CT-arthrogram images present abnormalities in a manner that resembles the ''in situ'' surgical findings, allowing management decisions to be made with greater confidence. The CT techniques for imaging the knee after arthrography are discussed, as is the use of plain CT

  10. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... are the limitations of CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed ... nasal cavity by small openings. top of page What are some common uses of the procedure? CT ...

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the limitations of CT Scanning of the Head? What is CT Scanning of the Head? Computed tomography, ... than regular radiographs (x-rays). top of page What are some common uses of the procedure? CT ...

  12. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... preferable over CT scanning. top of page Additional Information and Resources RTAnswers.org: Radiation Therapy for Bladder ...

  13. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) ... are the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a ...

  14. Indeterminate lesions on planar bone scintigraphy in lung cancer patients: SPECT, CT or SPECT-CT?

    International Nuclear Information System (INIS)

    Sharma, Punit; Kumar, Rakesh; Singh, Harmandeep; Bal, Chandrasekhar; Malhotra, Arun; Julka, Pramod Kumar; Thulkar, Sanjay

    2012-01-01

    The objective of the present study was to compare the role of single photon emission computed tomography (SPECT), computed tomography (CT) and SPECT-CT of selected volume in lung cancer patients with indeterminate lesions on planar bone scintigraphy (BS). The data of 50 lung cancer patients (53 ± 10.3 years; range 30-75; male/female 38/12) with 65 indeterminate lesions on planar BS (January 2010 to November 2010) were retrospectively evaluated. All of them underwent SPECT-CT of a selected volume. SPECT, CT and SPECT-CT images were independently evaluated by two experienced readers (experience in musculoskeletal imaging, including CT: 5 and 7 years) in separate sessions. A scoring scale of 1 to 5 was used, in which 1 is definitely metastatic, 2 is probably metastatic, 3 is indeterminate, 4 is probably benign and 5 is definitely benign. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated for each modality, taking a score ≤2 as metastatic. With receiver operating characteristic (ROC) curve analysis, areas under the curve (AUC) were calculated for each modality and compared. Clinical and imaging follow-up and/or histopathology were taken as reference standard. For both readers SPECT was inferior to CT (P = 0.004, P = 0.022) and SPECT-CT (P = 0.003, P = 0.037). However, no significant difference was found between CT and SPECT-CT for reader 1 (P = 0.847) and reader 2 (P = 0.592). The findings were similar for lytic as well as sclerotic lesions. Moderate inter-observer agreement was seen for SPECT images (κ = 0.426), while almost perfect agreement was seen for CT (κ = 0.834) and SPECT-CT (κ = 0.971). CT alone and SPECT-CT are better than SPECT for accurate characterisation of indeterminate lesions on planar BS in lung cancer patients. CT alone is not inferior to SPECT-CT for this purpose and might be preferred because of shorter acquisition time and wider availability. (orig.)

  15. Evaluation of CT in hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Nakao, Norio; Miura, Yukio; Ohnishi, Mitsunori; Kamikon-ya, Norihiko; Sakamoto, Yoshisato; Miura, Takashi; Sakamoto, Kiyoshi; Takayasu, Yoshio

    1985-06-01

    In order to evaluate the diagnostic ability of CT in hepatocellular carcinoma, four kinds of CT images were comparatively studied by the accuracy and ROC (receiver operating characteristic) curve analysis. As a result, it was clarified that CT images were evaluated more objectively by ROC curve analysis than by accuracy. The diagnostic ability of existence and differentiation of tumor in the liver were higher in order of plain CT, contrast enhanced CT (CECT), bolus CT and CT arteriography (CTA). Therefore, in an usual CT examination intended to make differential diagnosis in space occupying liver disease, bolus CT seems to be indispensable, and also CTA is essential where diagnosis is difficult even by bolus CT.

  16. Low-dose Dental-CT

    International Nuclear Information System (INIS)

    Gahleitner, A.; Imhof, H.; Homolka, P.; Fuerhauser, R.; Freudenthaler, J.; Watzek, G.

    2000-01-01

    Dental-CT is a relatively new, increasingly used investigation technique in dental radiology. Several authors have stated that the indication for Dental-CT has to be chosen on a strict basis, due to high dose values. This article describes the technique of performing dental-CT and calculates the effective dose based on published data and own measurements as well as the dose reduction potential to achieve an optimized protocol for Dental-CT investigations. (orig.) [de

  17. Dose calculation with respiration-averaged CT processed from cine CT without a respiratory surrogate

    International Nuclear Information System (INIS)

    Riegel, Adam C.; Ahmad, Moiz; Sun Xiaojun; Pan Tinsu

    2008-01-01

    Dose calculation for thoracic radiotherapy is commonly performed on a free-breathing helical CT despite artifacts caused by respiratory motion. Four-dimensional computed tomography (4D-CT) is one method to incorporate motion information into the treatment planning process. Some centers now use the respiration-averaged CT (RACT), the pixel-by-pixel average of the ten phases of 4D-CT, for dose calculation. This method, while sparing the tedious task of 4D dose calculation, still requires 4D-CT technology. The authors have recently developed a means to reconstruct RACT directly from unsorted cine CT data from which 4D-CT is formed, bypassing the need for a respiratory surrogate. Using RACT from cine CT for dose calculation may be a means to incorporate motion information into dose calculation without performing 4D-CT. The purpose of this study was to determine if RACT from cine CT can be substituted for RACT from 4D-CT for the purposes of dose calculation, and if increasing the cine duration can decrease differences between the dose distributions. Cine CT data and corresponding 4D-CT simulations for 23 patients with at least two breathing cycles per cine duration were retrieved. RACT was generated four ways: First from ten phases of 4D-CT, second, from 1 breathing cycle of images, third, from 1.5 breathing cycles of images, and fourth, from 2 breathing cycles of images. The clinical treatment plan was transferred to each RACT and dose was recalculated. Dose planes were exported at orthogonal planes through the isocenter (coronal, sagittal, and transverse orientations). The resulting dose distributions were compared using the gamma (γ) index within the planning target volume (PTV). Failure criteria were set to 2%/1 mm. A follow-up study with 50 additional lung cancer patients was performed to increase sample size. The same dose recalculation and analysis was performed. In the primary patient group, 22 of 23 patients had 100% of points within the PTV pass γ criteria

  18. Method for studying gas composition in the human mastoid cavity by use of laser spectroscopy.

    Science.gov (United States)

    Lindberg, Sven; Lewander, Märta; Svensson, Tomas; Siemund, Roger; Svanberg, Katarina; Svanberg, Sune

    2012-04-01

    We evaluated a method for gas monitoring in the mastoid cavity using tunable diode laser spectroscopy by comparing it to simultaneously obtained computed tomographic (CT) scans. The presented optical technique measures free gases, oxygen (O2), and water vapor (H2O) within human tissue by use of low-power diode lasers. Laser light was sent into the tip of the mastoid process, and the emerging light at the level of the antrum was captured with a detector placed on the skin. The absorption of H2O was used to monitor the probed gas volume of the mastoid cavity, and it was compared to the CT scan-measured volume. The ratio between O2 absorption and H2O absorption estimated the O2 content in the mastoid cavity and thus the ventilation. The parameters were compared to the grading of mastoid cavities based on the CT scans (n = 31). The reproducibility of the technique was investigated by measuring each mastoid cavity 4 times. Both O2 and H2O were detected with good reproducibility. The H2O absorption and the CT volume correlated (r = 0.69). The average ratio between the normalized O2 absorption and the H2O absorption signals was 0.7, indicating a lower O2 content than in surrounding air (expected ratio, 1.0), which is consistent with previous findings made by invasive techniques. All mastoid cavities with radiologic signs of disease were detected. Laser spectroscopy monitoring appears to be a usable tool for noninvasive investigations of gas composition in the mastoid cavity, providing important clinical information regarding size and ventilation.

  19. CT pelvimetry

    International Nuclear Information System (INIS)

    Vicens, J.L.; Charles, G.; Le Berre, J.; Flageat, J.

    1989-01-01

    Pelvimetry aims at providing the obstetrician with information on the size and morphology of the female pelvis, thus enabling him to assess the obstetrical prognosis as accurately as possible. Computed tomography (CT) has several advantages, in particular the lower mother and fetus radiation dose. After a brief description of obstetrical anatomy, the usual CT exploration method is presented and its results are considered in terms of measurements, indices and morphological findings. If performed with a very strict exploration procedure, CT pelvimetry is a very reliable, fact and comfortable method of examination. All these advantages, combined with the minimized patient dose, should lead to an increasingly widespread use of this technique [fr

  20. Characterisation of Liquid Slugs in Gas-Liquid Taylor Flow in Microchannels

    Czech Academy of Sciences Publication Activity Database

    Záloha, Petr; Křišťál, Jiří; Jiřičný, Vladimír; Völkel, N.; Xuereb, C.; Aubin, J.

    2012-01-01

    Roč. 68, č. 1 (2012), s. 640-649 ISSN 0009-2509 Grant - others:IMPULSE(XE) NMP2-CT-2005-011816 Institutional research plan: CEZ:AV0Z40720504 Keywords : gas-liquid * micro-piv * microreactor Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 2.386, year: 2012

  1. Detection of skeletal muscle metastasis: torso FDG PET-CT versus contrast-enhanced chest or abdomen CT.

    Science.gov (United States)

    So, Young; Yi, Jeong Geun; Song, Inyoung; Lee, Won Woo; Chung, Hyun Woo; Park, Jeong Hee; Moon, Sung Gyu

    2015-07-01

    Skeletal muscle metastasis (SMM) in cancer patients has not been sufficiently evaluated regarding prevalence and proper method of detection. To determine the prevalence of SMM and compare the diagnostic competencies for SMM of torso F-18 fluorodeoxyglucose (FDG) positron emission tomography-computed tomography (PET-CT) and contrast-enhanced chest or abdomen CT. We investigated 18,225 PET-CT studies of 6359 cancer patients performed from 2005 to 2012. The PET-CT studies describing potential SMM were retrieved and the corresponding medical records were reviewed. The gold standard for SMM was histopathologically-proven SMM or imaging study-based disease progression. The detectability of SMM was compared between PET-CT and contrast-enhanced CT. Twenty-six patients had 84 SMM lesions, representing a SMM prevalence of 0.41%. Lung cancer was the most common SMM-associated malignancy (54%) and the gluteal/pelvic girdle muscle was the most frequently involved SMM site (37%). All 84 SMM lesions were visualized on PET-CT (100%). Of these PET-CT positive 84 SMM lesions, 51 lesions were in the CT field of view (FOV) (61%), whereas 33 lesions were out of the CT FOV (39%). Among these 51 lesions, 17 lesions showed rim-enhancing nodules/masses (33%), eight lesions showed homogeneously enhancing nodules (16%), three lesions showed heterogeneously enhancing nodules (6%), and 23 SMM lesions (45%) were non-diagnostic by CT. All 51 SMM lesions within CT FOV were detected on PET-CT (100%), whereas only 28 were visualized on CT (54.9%), resulting in a significant difference (P SMM was revealed by PET-CT. The prevalence of SMM was as low as 0.41% in the current large cohort of cancer patients. Torso PET-CT was a more competent modality than contrast-enhanced CT in the detection of SMM. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  2. CT-based postimplant dosimetry of prostate brachytherapy. Comparison of 1-mm and 5-mm section CT

    International Nuclear Information System (INIS)

    Tanaka, Osamu; Hayashi, Shinya; Kanematsu, Masayuki; Matsuo, Masayuki; Hoshi, Hiroaki; Nakano, Masahiro; Maeda, Sanaho; Deguchi, Takashi; Hoshi, Hiroaki

    2007-01-01

    The aim of this study was to compare the outcomes between 1-mm and 5-mm section computed tomography (CT)-based postimplant dosimetry. A series of 21 consecutive patients underwent permanent prostate brachytherapy. The postimplant prostate volume was calculated using 1-mm and 5-mm section CT. One radiation oncologist contoured the prostate on CT images to obtain the reconstructed prostate volume (pVol), prostate V 100 (percent of the prostate volume receiving at least the full prescribed dose), and prostate D 90 (mean dose delivered to 90% of the prostate gland). The same radiation oncologist performed the contouring three times to evaluate intraobserver variation and subjectively scored the quality of the CT images. The mean ±1 standard deviation (SD) postimplant pVol was 20.17±6.66 cc by 1-mm section CT and 22.24±8.48 cc by 5-mm section CT; the difference in the mean values was 2.06 cc (P 100 was 80.44%±7.06% by 1-mm section CT and 77.33%±10.22% by 5-mm section CT. The mean postimplant prostate D 90 was 83.28%±10.81% by 1-mm section CT and 78.60%±15.75% by 5-mm section CT. In the evaluation of image quality, 5-mm section CT was assigned significantly higher scores than 1-mm section CT. In regard to intraobserver variation, 5-mm section CT revealed less intraobserver variation than 1-mm section CT. Our current results suggested that the outcomes of postimplant dosimetry using 1-mm section CT did not improved the results over those obtained using 5-mm section CT in terms of the quality of the CT image or reproducibility. (author)

  3. Benign hepatic portal venous gas following blunt abdominal trauma

    International Nuclear Information System (INIS)

    Dill-Mackay, M.J.

    1997-01-01

    A 71-year-old man presented to Royal Perth Hospital Emergency Department with back pain following a fall from the roof of his house. There was no history of loss of consciousness. Physical examination revealed epigastric tenderness and guarding and a suspicion of CSF otorrhoea. All other clinical parameters were normal. His past medical history included alcohol abuse, chronic obstructive airways disease, peripheral vascular disease, cerebellar infarction and a right total hip replacement. Spinal radiographs demonstrated crush fractures involving the T12 and L1 vertebral bodies and a CT scan of the skull base was normal. An abdominal CT scan performed with intravenous contrast demonstrated gas within the portal veins of the anterior segments of the liver and a small fluid collection in the anterior pararenal space. During the ensuing 24 hours a repeat non-contrast abdominal Ct scan was performed and reveled complete resolution of the fluid. No other intra-abdominal abnormality was detected to warrant an invasive procedure

  4. Benign hepatic portal venous gas following blunt abdominal trauma

    Energy Technology Data Exchange (ETDEWEB)

    Dill-Mackay, M.J. [Royal Perth Hospital, Perth, WA (Australia). Department of Radiology

    1997-05-01

    A 71-year-old man presented to Royal Perth Hospital Emergency Department with back pain following a fall from the roof of his house. There was no history of loss of consciousness. Physical examination revealed epigastric tenderness and guarding and a suspicion of CSF otorrhoea. All other clinical parameters were normal. His past medical history included alcohol abuse, chronic obstructive airways disease, peripheral vascular disease, cerebellar infarction and a right total hip replacement. Spinal radiographs demonstrated crush fractures involving the T12 and L1 vertebral bodies and a CT scan of the skull base was normal. An abdominal CT scan performed with intravenous contrast demonstrated gas within the portal veins of the anterior segments of the liver and a small fluid collection in the anterior pararenal space. During the ensuing 24 hours a repeat non-contrast abdominal Ct scan was performed and reveled complete resolution of the fluid. No other intra-abdominal abnormality was detected to warrant an invasive procedure. 20 refs., 1 tab., 2 figs.

  5. Functional CT imaging: load-dependent visualization of the subchondral mineralization by means of CT osteoabsorptionmetry (CT-OAM); Funktionelle Computertomographie: Beanspruchungsabhaengige Darstellung der subchondralen Mineralisierung mittels CT gestuetzter Osteoabsorptiometrie (CTOAM)

    Energy Technology Data Exchange (ETDEWEB)

    Linsenmaier, U.; Schlichtenhorst, K.; Pfeifer, K.J.; Reiser, M. [Inst. fuer Klinische Radiologie, Innenstadt, Ludwig-Maximilians-Univ. Muenchen (Germany); Kersting, S.; Putz, R.; Mueller-Gerbl, M. [Anatomische Anstalt, Ludwig-Maximilians-Univ. Muenchen (Germany)

    2003-05-01

    Purpose: Functional computed tomography for visualization and quantification of subchondral bone mineralization using CT osteoabsorptiometry (CT-OAM). Materials and Methods: Tarsometatarsal (TMT) and metatarsophalangeal (MTP) joints of 46 human hallux valgus (HV) specimens were examined (sagittal 1/1/1 mm) on a single slice CT scanner SCT (Somatom Plus 4, Siemens AG). Subchondral bone pixels were segmented and assigned to 10 density value groups (triangle 100 HU, range 200 - 1200 HU) the pixels using volume rendering technique (VRT). The data analysis considered the severity of HV as determined by the radiographically measured HV-angle (a.p. projection). Results: CT-OAM could generate reproducible densitograms of the distribution pattern of the subchondral bone density for all four joint surfaces (TMT and MTP joints). The bone density localization enables the assignment to different groups, showing a characteristic HV-angle-dependent distribution of the maximum bone mineralization of the load-dependent densitogram (p < 0.001). Conclusion: CT-OAM is a functional CT technique for visualizing and quantifying the distribution of the subchondral bone density, enabling a noninvasive load-dependent assessment of the joint surfaces. Load-dependent densitograms of hallux valgus specimens show a characteristic correlation with an increase of the HV-angle. (orig.) [German] Ziel: Darstellung und Quantifizierung der subchondralen Mineralisierung in Abhaengigkeit von unterschiedlichen Beanspruchungssituationen mittels funktioneller Computertomographie als CT-Osteoabsorptiometrie (CT-OAM). Methode: An 46 humanen Praeparaten mit Hallux valgus (HV) wurden exemplarisch die TMT I (Tarsometatarsal)- und MTP I (Metatarsophalangeal)-Gelenke des ersten Strahles (sagittal 1/1/1 mm) an einem Singleslice Spiral-CT (SCT, Somatom Plus 4, Siemens AG) untersucht. Der subchondrale Knochen wurde segmentiert, den Pixel wurde mittels Volume Rendering Technik (VRT) 10 Graustufenbereiche (D100 HU

  6. FDG-PET/contrast-enhanced CT as a post-treatment tool in head and neck squamous cell carcinoma: comparison with FDG-PET/non-contrast-enhanced CT and contrast-enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    Suenaga, Yuko; Kitajima, Kazuhiro; Sugimura, Kazuro [Kobe University Graduate School of Medicine, Department of Radiology, Kobe (Japan); Ishihara, Takeaki; Sasaki, Ryohei [Kobe University Graduate, School of Medicine, Department of Radiology, Division of Radiation Oncology, Kobe (Japan); Otsuki, Naoki; Nibu, Ken-ichi [Kobe University Graduate, School of Medicine, Department of Otolaryngology-Head and Neck Surgery, Kobe (Japan); Minamikawa, Tsutomu [Kobe University Graduate School of Medicine, Department of Oral and Maxillofacial Surgery, Kobe (Japan); Kiyota, Naomi [Kobe University Hospital, Department of Medical Oncology and Hematology, Kobe (Japan)

    2016-04-15

    To evaluate the accuracy of PET/CT using {sup 18}F-fluorodeoxyglucose (FDG) with IV contrast for suspected recurrent head and neck squamous cell carcinoma (HNSCC). One hundred and seventy patients previously treated for HNSCC underwent PET/CT, consisting of non-contrast-enhanced and contrast-enhanced CT, to investigate suspected recurrence. Diagnostic performance of PET/contrast-enhanced CT (PET/ceCT), PET/non-contrast-enhanced CT (PET/ncCT) and contrast-enhanced CT (ceCT) for local or regional recurrence, distant metastasis, overall recurrence and second primary cancer was evaluated. The reference standard included histopathology, treatment change and imaging follow-up. The patient-based areas under the receiver operating characteristic curves (AUC) for ceCT, PET/ncCT and PET/ceCT were 0.82, 0.96 and 0.98 for local recurrence, 0.73, 0.86 and 0.86 for regional recurrence, 0.86, 0.91 and 0.92 for distant metastasis, 0.72, 0.86 and 0.87 for overall recurrence, and 0.86, 0.89 and 0.91 for a second primary cancer. Both PET/ceCT and PET/ncCT statistically showed larger AUC than ceCT for recurrence, and the difference between PET/ceCT and PET/ncCT for local recurrence reached a significant level (p = 0.039). The accuracy of PET/ceCT for diagnosing overall recurrence was high, irrespective of the time interval after the last treatment (83.3-94.1 %). FDG-PET/CT was a more accurate HNSCC restaging tool than ceCT. The added value of ceCT at FDG-PET/CT is minimal. (orig.)

  7. Comparison SPECT-CT with PET-CT in several applications of small-animal models

    International Nuclear Information System (INIS)

    Pan Yifan; Song Shaoli; Huang Gang

    2009-01-01

    With the development of medical science, monitoring dynamic biologic processes in small-animal models of diseases has become one of the most important approaches in medical studies. Important physiologic parameters that traditionally have been characterized by nuclear medicine imaging include blood flow, biochemical metabolism, and cellular receptors. Recently, nuclear medicine has been greatly facilitated by the newer development of dual-modality integrated imaging systems (SPECT-CT and PET-CT), which provide functional and anatomical images in the same scanning session, with the acquired images co-registered by means of the hardware. The purpose of this review is to compare SPECT-CT with PET-CT in several applications of small-animal models. Conclusicn: PET-CT for small animal modes in nledical research in the applications has great advantages, but SPECT-CT is still a very important role, and research low cost. (authors)

  8. Improved quantitation and reproducibility in multi-PET/CT lung studies by combining CT information.

    Science.gov (United States)

    Holman, Beverley F; Cuplov, Vesna; Millner, Lynn; Endozo, Raymond; Maher, Toby M; Groves, Ashley M; Hutton, Brian F; Thielemans, Kris

    2018-06-05

    Matched attenuation maps are vital for obtaining accurate and reproducible kinetic and static parameter estimates from PET data. With increased interest in PET/CT imaging of diffuse lung diseases for assessing disease progression and treatment effectiveness, understanding the extent of the effect of respiratory motion and establishing methods for correction are becoming more important. In a previous study, we have shown that using the wrong attenuation map leads to large errors due to density mismatches in the lung, especially in dynamic PET scans. Here, we extend this work to the case where the study is sub-divided into several scans, e.g. for patient comfort, each with its own CT (cine-CT and 'snap shot' CT). A method to combine multi-CT information into a combined-CT has then been developed, which averages the CT information from each study section to produce composite CT images with the lung density more representative of that in the PET data. This combined-CT was applied to nine patients with idiopathic pulmonary fibrosis, imaged with dynamic 18 F-FDG PET/CT to determine the improvement in the precision of the parameter estimates. Using XCAT simulations, errors in the influx rate constant were found to be as high as 60% in multi-PET/CT studies. Analysis of patient data identified displacements between study sections in the time activity curves, which led to an average standard error in the estimates of the influx rate constant of 53% with conventional methods. This reduced to within 5% after use of combined-CTs for attenuation correction of the study sections. Use of combined-CTs to reconstruct the sections of a multi-PET/CT study, as opposed to using the individually acquired CTs at each study stage, produces more precise parameter estimates and may improve discrimination between diseased and normal lung.

  9. Physics and basic technology of CT

    International Nuclear Information System (INIS)

    Mahesh, Mahadevappa

    2017-01-01

    Computed Tomography is one of the prime imaging modalities in any hospital around the globe. From its inception in 1973, CT technology have advanced leaps and bounds in medical diagnosis. Advances in X-ray tubes, detection technologies and image reconstruction methods led to the development of multiple-row detector CT (MDCT) technologies in early 2000, that has been the impetus for new fields such as Cardiovascular CT, Hybrid CT (PET-CT and SPECT-CT), CT Perfusion, Cone Beam CT, etc. It is now possible to image the entire organ (such as heart) in less than 0.3 seconds providing isotropic resolution images with high temporal resolution. With all X-ray imaging modalities, including CT, the concern is the radiation dose. Since CT procedures are one of the major imaging procedures performed in any hospital, it is important to optimize CT protocols in order to provide quality images at optimal radiation dose

  10. X-ray CT for quantitative food microstructure engineering: The apple case

    International Nuclear Information System (INIS)

    Herremans, Els; Verboven, Pieter; Defraeye, Thijs; Rogge, Seppe; Ho, Quang Tri; Hertog, Maarten L.A.T.M.; Verlinden, Bert E.; Bongaers, Evi; Wevers, Martine; Nicolai, Bart M.

    2014-01-01

    Highlights: • Diffusivity of O 2 and CO 2 in Braeburn tissue were computed from X-ray micro-CT data. • Diffusivities were different for the distinct stages of ‘Braeburn’ browning disorder. • Microstructural gas transport constants were implemented in models of intact fruit. • We simulated internal O 2 concentrations for longterm storage treatments of Braeburn. • This engineering approach can optimize internal quality of apple during CA storage. - Abstract: Apple fruit is a major crop that can be supplied year-round due to low temperature storage in a controlled atmosphere with a reduced oxygen concentration and an increased carbon dioxide concentration. The low temperature and dedicated gas concentration levels are designed to provide optimal conditions that prevent ripening while maintaining the fundamental respiratory metabolism necessary for energy supply in the cells that ensures cell and tissue integrity during storage of the fruit. If the concentration of oxygen is too low or that of carbon dioxide too high, a fermentation metabolism is induced that causes the production of off-flavours, results in insufficient energy supply, leading to cell collapse and consequent tissue browning and cavity formation. The microstructural arrangement of cells and intercellular spaces in the apple create specific pathways for transport of the respiratory gasses oxygen and carbon dioxide. We used X-ray CT to characterise the changes in the microstructure of ‘Braeburn’ apple during the development of internal storage disorders. Multiscale modeling was applied to understand the changes in oxygen and carbon dioxide concentrations and respiration and fermentation rates in the apple during the disorder development in controlled atmosphere storage of ‘Braeburn’ apple fruit. The 3D microstructure geometries of healthy, brown tissue and tissue with cavities were created to solve the micro-scale gas-exchange model for O 2 and CO 2 using the finite volume method

  11. X-ray CT for quantitative food microstructure engineering: The apple case

    Energy Technology Data Exchange (ETDEWEB)

    Herremans, Els, E-mail: els.herremans@biw.kuleuven.be [BIOSYST-MeBioS, KU Leuven, Willem de Croylaan 42, 3001 Leuven (Belgium); Verboven, Pieter; Defraeye, Thijs; Rogge, Seppe; Ho, Quang Tri; Hertog, Maarten L.A.T.M. [BIOSYST-MeBioS, KU Leuven, Willem de Croylaan 42, 3001 Leuven (Belgium); Verlinden, Bert E. [VCBT, Flanders Centre of Postharvest Technology, Willem de Croylaan 42, 3001 Leuven (Belgium); Bongaers, Evi [Bruker microCT, Kartuizersweg 3B, 2550 Kontich (Belgium); Wevers, Martine [MTM, KU Leuven, Kasteelpark Arenberg 44, 3001 Leuven (Belgium); Nicolai, Bart M. [BIOSYST-MeBioS, KU Leuven, Willem de Croylaan 42, 3001 Leuven (Belgium); VCBT, Flanders Centre of Postharvest Technology, Willem de Croylaan 42, 3001 Leuven (Belgium)

    2014-04-01

    Highlights: • Diffusivity of O{sub 2} and CO{sub 2} in Braeburn tissue were computed from X-ray micro-CT data. • Diffusivities were different for the distinct stages of ‘Braeburn’ browning disorder. • Microstructural gas transport constants were implemented in models of intact fruit. • We simulated internal O{sub 2} concentrations for longterm storage treatments of Braeburn. • This engineering approach can optimize internal quality of apple during CA storage. - Abstract: Apple fruit is a major crop that can be supplied year-round due to low temperature storage in a controlled atmosphere with a reduced oxygen concentration and an increased carbon dioxide concentration. The low temperature and dedicated gas concentration levels are designed to provide optimal conditions that prevent ripening while maintaining the fundamental respiratory metabolism necessary for energy supply in the cells that ensures cell and tissue integrity during storage of the fruit. If the concentration of oxygen is too low or that of carbon dioxide too high, a fermentation metabolism is induced that causes the production of off-flavours, results in insufficient energy supply, leading to cell collapse and consequent tissue browning and cavity formation. The microstructural arrangement of cells and intercellular spaces in the apple create specific pathways for transport of the respiratory gasses oxygen and carbon dioxide. We used X-ray CT to characterise the changes in the microstructure of ‘Braeburn’ apple during the development of internal storage disorders. Multiscale modeling was applied to understand the changes in oxygen and carbon dioxide concentrations and respiration and fermentation rates in the apple during the disorder development in controlled atmosphere storage of ‘Braeburn’ apple fruit. The 3D microstructure geometries of healthy, brown tissue and tissue with cavities were created to solve the micro-scale gas-exchange model for O{sub 2} and CO{sub 2} using the

  12. SU-F-J-109: Generate Synthetic CT From Cone Beam CT for CBCT-Based Dose Calculation

    Energy Technology Data Exchange (ETDEWEB)

    Wang, H; Barbee, D; Wang, W; Pennell, R; Hu, K; Osterman, K [Department of Radiation Oncology, NYU Langone Medical Center, New York, NY (United States)

    2016-06-15

    Purpose: The use of CBCT for dose calculation is limited by its HU inaccuracy from increased scatter. This study presents a method to generate synthetic CT images from CBCT data by a probabilistic classification that may be robust to CBCT noise. The feasibility of using the synthetic CT for dose calculation is evaluated in IMRT for unilateral H&N cancer. Methods: In the training phase, a fuzzy c-means classification was performed on HU vectors (CBCT, CT) of planning CT and registered day-1 CBCT image pair. Using the resulting centroid CBCT and CT values for five classified “tissue” types, a synthetic CT for a daily CBCT was created by classifying each CBCT voxel to obtain its probability belonging to each tissue class, then assigning a CT HU with a probability-weighted summation of the classes’ CT centroids. Two synthetic CTs from a CBCT were generated: s-CT using the centroids from classification of individual patient CBCT/CT data; s2-CT using the same centroids for all patients to investigate the applicability of group-based centroids. IMRT dose calculations for five patients were performed on the synthetic CTs and compared with CT-planning doses by dose-volume statistics. Results: DVH curves of PTVs and critical organs calculated on s-CT and s2-CT agree with those from planning-CT within 3%, while doses calculated with heterogeneity off or on raw CBCT show DVH differences up to 15%. The differences in PTV D95% and spinal cord max are 0.6±0.6% and 0.6±0.3% for s-CT, and 1.6±1.7% and 1.9±1.7% for s2-CT. Gamma analysis (2%/2mm) shows 97.5±1.6% and 97.6±1.6% pass rates for using s-CTs and s2-CTs compared with CT-based doses, respectively. Conclusion: CBCT-synthesized CTs using individual or group-based centroids resulted in dose calculations that are comparable to CT-planning dose for unilateral H&N cancer. The method may provide a tool for accurate dose calculation based on daily CBCT.

  13. SU-F-J-109: Generate Synthetic CT From Cone Beam CT for CBCT-Based Dose Calculation

    International Nuclear Information System (INIS)

    Wang, H; Barbee, D; Wang, W; Pennell, R; Hu, K; Osterman, K

    2016-01-01

    Purpose: The use of CBCT for dose calculation is limited by its HU inaccuracy from increased scatter. This study presents a method to generate synthetic CT images from CBCT data by a probabilistic classification that may be robust to CBCT noise. The feasibility of using the synthetic CT for dose calculation is evaluated in IMRT for unilateral H&N cancer. Methods: In the training phase, a fuzzy c-means classification was performed on HU vectors (CBCT, CT) of planning CT and registered day-1 CBCT image pair. Using the resulting centroid CBCT and CT values for five classified “tissue” types, a synthetic CT for a daily CBCT was created by classifying each CBCT voxel to obtain its probability belonging to each tissue class, then assigning a CT HU with a probability-weighted summation of the classes’ CT centroids. Two synthetic CTs from a CBCT were generated: s-CT using the centroids from classification of individual patient CBCT/CT data; s2-CT using the same centroids for all patients to investigate the applicability of group-based centroids. IMRT dose calculations for five patients were performed on the synthetic CTs and compared with CT-planning doses by dose-volume statistics. Results: DVH curves of PTVs and critical organs calculated on s-CT and s2-CT agree with those from planning-CT within 3%, while doses calculated with heterogeneity off or on raw CBCT show DVH differences up to 15%. The differences in PTV D95% and spinal cord max are 0.6±0.6% and 0.6±0.3% for s-CT, and 1.6±1.7% and 1.9±1.7% for s2-CT. Gamma analysis (2%/2mm) shows 97.5±1.6% and 97.6±1.6% pass rates for using s-CTs and s2-CTs compared with CT-based doses, respectively. Conclusion: CBCT-synthesized CTs using individual or group-based centroids resulted in dose calculations that are comparable to CT-planning dose for unilateral H&N cancer. The method may provide a tool for accurate dose calculation based on daily CBCT.

  14. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  16. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT ...

  17. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT ...

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT ...

  19. Diagnosis of bowel infarction: a comparison of plain films and CT scans in 23 cases.

    Science.gov (United States)

    Smerud, M J; Johnson, C D; Stephens, D H

    1990-01-01

    We retrospectively reviewed abdominal CT and plain film findings in 23 proved cases of mesenteric infarction to compare the value of the two techniques. Criteria considered specific for infarction on CT were identified in nine (39%) of 23 patients and comprised pneumatosis in seven patients (30%), mesenteric or portal venous gas in three patients (13%), and focally thick-walled bowel in two patients (9%). Criteria considered specific for bowel infarction on plain films were identified in seven (30%) of 23 patients and comprised focally edematous bowel in six patients (26%) and pneumatosis intestinalis in one patient (4%). Only one patient had specific changes on both CT and plain films, but 15 (65%) of the 23 showed specific changes on at least one study. The results indicate that plain films remain an important tool in patients suspected of mesenteric infarction and can provide information that is complementary to CT. Also, as both studies were nonspecific in eight (35%) of our patients, negative or nonspecific findings should not deter further diagnostic or interventional procedures in patients in whom the clinical suspicion of bowel infarction is high.

  20. CT of the heart

    International Nuclear Information System (INIS)

    Lipton, M.J.

    1986-01-01

    Advances based upon the detector elements instead of X-ray film have greatly increased the power of X-ray imaging. Computed tomography (CT) creates cross sectional rather than projected images. Recently, high speed CT devices have been developed for cardiovascular studies. The Cine-CT scanner employs a scanning electron beam deflected on an extended tungsten target ring. Fast scans of 50 millisecond exposures at multiple levels can provide information concerning blood flow in vessels and tissues, myocardial wall motion, valve integrity, coronary bypass graft patency and proximal coronary artery anatomy. Cine-CT dynamic scanning can also provide volume imaging with small quantities (0.05 - 1.5 ml/kg) of contrast medium administered via peripheral vein injections. Cine-CT provides simultaneous measurements of cardiac dimensions and function and is rapidly becoming a new tool for quantitating myocardial blood flow, cardiac chamber volumes and wall mechanics. The future outlook is very promising for this three-dimensional cine-CT technique with high spatial resolution. High speed CT should provide unique diagnostic information and as the technology continues to improve at a rapid speed, this new imaging modality could be a challenge for angiography. (Auth.)

  1. CT-docking patient stretcher

    International Nuclear Information System (INIS)

    Mirvis, S.E.; Owens, E.; Maslyn, J.; Rizutto, M.

    1990-01-01

    This paper assesses the use of a patient stretcher that directly docks to a CT scanner for acutely injured and/or critically ill patients. The stretcher permits performance of radiography and acts as a platform for critical care monitoring and patient support devices. During a 1-year period, the prototype CT-docking stretcher was used for 35 patients sustaining acute trauma and 25 patients from critical care units. Observations were elicited from physicians, nurses and technologists concerning the advantages or disadvantages of the docking stretcher. Advantages of the CT-docking stretcher included time saved in moving patients to the CT table from the admitting/emergency ward, transfer of critically ill patients onto the stretcher in the controlled environment of the intensive care unit rather than the CT suite, increasing CT throughput by direct docking of the patient stretcher to the CT scanner rather than manual transfer of complex support and monitoring devices with the patient, decreased risk associated with physical movement of patients with potentially unstable spinal injuries or unstable physiologic status, and decrease in potential for injury to medical personnel performing patient transfer

  2. Radiation dose and cancer risk from pediatric CT examinations on 64-slice CT: A phantom study

    International Nuclear Information System (INIS)

    Feng Shiting; Law, Martin Wai-Ming; Huang Bingsheng; Ng, Sherry; Li Ziping; Meng Quanfei; Khong, Pek-Lan

    2010-01-01

    Objective: To measure the radiation dose from CT scans in an anthropomorphic phantom using a 64-slice MDCT, and to estimate the associated cancer risk. Materials and methods: Organ doses were measured with a 5-year-old phantom and thermoluminescent dosimeters. Four protocols; head CT, thorax CT, abdomen CT and pelvis CT were studied. Cancer risks, in the form of lifetime attributable risk (LAR) of cancer incidence, were estimated by linear extrapolation using the organ radiation doses and the LAR data. Results: The effective doses for head, thorax, abdomen and pelvis CT, were 0.7 mSv, 3.5 mSv, 3.0 mSv, 1.3 mSv respectively. The organs with the highest dose were; for head CT, salivary gland (22.33 mGy); for thorax CT, breast (7.89 mGy); for abdomen CT, colon (6.62 mGy); for pelvis CT, bladder (4.28 mGy). The corresponding LARs for boys and girls were 0.015-0.053% and 0.034-0.155% respectively. The organs with highest LARs were; for head CT, thyroid gland (0.003% for boys, 0.015% for girls); for thorax CT, lung for boys (0.014%) and breast for girls (0.069%); for abdomen CT, colon for boys (0.017%) and lung for girls (0.016%); for pelvis CT, bladder for both boys and girls (0.008%). Conclusion: The effective doses from these common pediatric CT examinations ranged from 0.7 mSv to 3.5 mSv and the associated lifetime cancer risks were found to be up to 0.16%, with some organs of higher radiosensitivity including breast, thyroid gland, colon and lungs.

  3. Hydrogen-Enhanced Natural Gas Vehicle Program

    Energy Technology Data Exchange (ETDEWEB)

    Hyde, Dan; Collier, Kirk

    2009-01-22

    The project objective is to demonstrate the viability of HCNG fuel (30 to 50% hydrogen by volume and the remainder natural gas) to reduce emissions from light-duty on-road vehicles with no loss in performance or efficiency. The City of Las Vegas has an interest in alternative fuels and already has an existing hydrogen refueling station. Collier Technologies Inc (CT) supplied the latest design retrofit kits capable of converting nine compressed natural gas (CNG) fueled, light-duty vehicles powered by the Ford 5.4L Triton engine. CT installed the kits on the first two vehicles in Las Vegas, trained personnel at the City of Las Vegas (the City) to perform the additional seven retrofits, and developed materials for allowing other entities to perform these retrofits as well. These vehicles were used in normal service by the City while driver impressions, reliability, fuel efficiency and emissions were documented for a minimum of one year after conversion. This project has shown the efficacy of operating vehicles originally designed to operate on compressed natural gas with HCNG fuel incorporating large quantities of exhaust gas recirculation (EGR). There were no safety issues experienced with these vehicles. The only maintenance issue in the project was some rough idling due to problems with the EGR valve and piping parts. Once the rough idling was corrected no further maintenance issues with these vehicles were experienced. Fuel economy data showed no significant changes after conversion even with the added power provided by the superchargers that were part of the conversions. Driver feedback for the conversions was very favorable. The additional power provided by the HCNG vehicles was greatly appreciated, especially in traffic. The drivability of the HCNG vehicles was considered to be superior by the drivers. Most of the converted vehicles showed zero oxides of nitrogen throughout the life of the project using the State of Nevada emissions station.

  4. Methane hydrate distribution from prolonged and repeated formation in natural and compacted sand samples: X-ray CT observations

    Energy Technology Data Exchange (ETDEWEB)

    Rees, E.V.L.; Kneafsey, T.J.; Seol, Y.

    2010-07-01

    To study physical properties of methane gas hydrate-bearing sediments, it is necessary to synthesize laboratory samples due to the limited availability of cores from natural deposits. X-ray computed tomography (CT) and other observations have shown gas hydrate to occur in a number of morphologies over a variety of sediment types. To aid in understanding formation and growth patterns of hydrate in sediments, methane hydrate was repeatedly formed in laboratory-packed sand samples and in a natural sediment core from the Mount Elbert Stratigraphic Test Well. CT scanning was performed during hydrate formation and decomposition steps, and periodically while the hydrate samples remained under stable conditions for up to 60 days. The investigation revealed the impact of water saturation on location and morphology of hydrate in both laboratory and natural sediments during repeated hydrate formations. Significant redistribution of hydrate and water in the samples was observed over both the short and long term.

  5. CT arteriography of the upper abdomen

    Energy Technology Data Exchange (ETDEWEB)

    Hasuo, K; Matsuura, K; Baba, H; Numaguchi, Y; Komaki, S [Kyushu Univ., Fukuoka (Japan). Faculty of Medicine

    1980-04-01

    The technique of CT arteriography was introduced, and CT images of the upper abdomen were explained. Very clear enhancement of parenchyma and vessels (especially portal vein) of the object organs could be obtained by CT arteriography of the upper abdomen, anatomical structures of organs were identified more easily by CT arteriography than by conventional CT, and the amount of information obtained was increased by using CT arteriography. However, the indication of CT arteriography must be limited, because of its complexity that CT arteriography is performed after angiography and involves the invasion of patients' bodies. As described in many reports, CT arteriography is useful for malignant tumors of the liver, and it is worthwhile, especially when surgery for hepatocellular carcinoma is considered. CT arteriography for organs except the liver has not been discussed sufficiently. Therefore, an application of this method for other organs must be decided after consideration of the balance of the amount of information obtained by CT arteriography with invasion to patients.

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Radiation Dose in X-Ray and CT Exams Blood Clots CT Perfusion of the Head CT Angiography ( ...

  7. Functional CT imaging: load-dependent visualization of the subchondral mineralization by means of CT osteoabsorptionmetry (CT-OAM)

    International Nuclear Information System (INIS)

    Linsenmaier, U.; Schlichtenhorst, K.; Pfeifer, K.J.; Reiser, M.; Kersting, S.; Putz, R.; Mueller-Gerbl, M.

    2003-01-01

    Purpose: Functional computed tomography for visualization and quantification of subchondral bone mineralization using CT osteoabsorptiometry (CT-OAM). Materials and Methods: Tarsometatarsal (TMT) and metatarsophalangeal (MTP) joints of 46 human hallux valgus (HV) specimens were examined (sagittal 1/1/1 mm) on a single slice CT scanner SCT (Somatom Plus 4, Siemens AG). Subchondral bone pixels were segmented and assigned to 10 density value groups (triangle 100 HU, range 200 - 1200 HU) the pixels using volume rendering technique (VRT). The data analysis considered the severity of HV as determined by the radiographically measured HV-angle (a.p. projection). Results: CT-OAM could generate reproducible densitograms of the distribution pattern of the subchondral bone density for all four joint surfaces (TMT and MTP joints). The bone density localization enables the assignment to different groups, showing a characteristic HV-angle-dependent distribution of the maximum bone mineralization of the load-dependent densitogram (p [de

  8. CT diagnosis of the primary lung cancer and usefulness of biopsy under CT

    International Nuclear Information System (INIS)

    Fujisawa, Hidefumi; Kushihashi, Tamio

    2011-01-01

    CT especially plays an important role in imaging diagnosis of lung cancer (LC) which gives quite multiple CT findings and this paper describes details to be noted for CT findings of individual lung lesion and cancer according to 5 classes below, together with usefulness of CT-guided biopsy and positron emission tomography (PET) usage. Explained are as follows: Important points in histopathology and CT findings from adenomatous hyperplasia (AH) to atypical AH (pre-invasive lesion); Differential CT diagnosis of benignity or malignancy of pulmonary nodes and tumors; Typical CT findings of LC of peripheral type of invasive or exclusive proliferative type, and pulmonary hillar type; Atypical CT findings of LC/having atypical inner structure such as presenting atypical calcification and atypical cavity/having atypical morphology such as presenting pneumonia-like finding, exhibiting regular or linear edge, and existing at atypical region like extrapleural lumen /having atypical progression rate such as showing rapid or slow doubling time of the volume and shrinking tentatively during the progress/of juvenile LC/and generated from background lung diseases such as interstitial pneumonia, tuberculosis, pneumoconiosis like asbestosis, pneumosilicosis, and pulmonary emphysema and bulla; and Regional ground glass opacity. As well, authors mention about the usefulness of CT-guided needle biopsy of the pulmonary lesion which enables to take the nodal specimen as small as <10 mm. Most frequent complication of the biopsy is pneumothorax (10-50%). How to use PET for LC examination is also commented with its usability and limitation. (T.T.)

  9. CT of thymoma

    Energy Technology Data Exchange (ETDEWEB)

    Sone, S.; Higashihara, T.; Morimoto, S.; Ikezoe, J.; Arisawa, J. (Osaka Univ. (Japan). Faculty of Medicine)

    1982-08-01

    Based on 17 patients with thymoma (8 with myasthenia gravis and 9 free from it); 1. The effectiveness of CT, conventional radiography and pneumomediastinography in the detection of thymomas was determined and the results compared. 2. The CT findings of thymomas were discussed and the CT features which seemed to suggest malignant thymomas were evaluated. The results were as follows: 1. Of the 17 cass with thymomas, 13 were diagnosed from p-a films, 13 from lateral films, and 16 from CT. Of the 16 thymomas, 14 were diagnosed from lateral tomography. Mass densities were shown in all 15 cases in which pneumomediastinography were performed. 2. Benign thymomas showed round or oval smoothly marginated mass. The fatty plane between the mass and the mediastinal structures was nicely preserved. 3. Malignant thymoma frequently showed a plaque-like mass with more or less irregular or lobulated contours with obliteration of the fatty planes of the cardiovascular structures. Tumor calcification was shown in 4 of 10 malignant thymomas. 4. Slight tumor invasion to the mediastinal pleura and lung was difficult to predict from the CT images.

  10. Preoperative evaluation of renal anatomy and renal masses with helical CT, 3D-CT and 3D-CT angiography.

    Science.gov (United States)

    Toprak, Uğur; Erdoğan, Aysun; Gülbay, Mutlu; Karademir, Mehmet Alp; Paşaoğlu, Eşref; Akar, Okkeş Emrah

    2005-03-01

    The aim of this prospective study was to determine the efficacy of three-dimensional computed tomography (3D-CT) and three-dimensional computed tomographic angiography (3D-CTA) that were reconstructed by using the axial images of the multiphasic helical CT in the preoperative evaluation of renal masses and demonstration of renal anatomy. Twenty patients that were suspected of having renal masses upon initial physical examination and ultrasonographic evaluation were examined through multiphasic helical CT. Two authors executed CT evaluations. Axial images were first examined and then used to reconstruct 3D-CT and 3D- CTA images. Number, location and size of the renal masses and other findings were noted. Renal vascularization and relationships of the renal masses with the neighboring renal structures were further investigated with 3D-CT and 3D-CTA images. Out of 20 patients, 13 had histopathologically proven renal cell carcinoma. The diagnoses of the remaining seven patients were xanthogranulomatous pyelonephritis, abscess, simple cyst, infected cyst, angiomyolipoma, oncocytoma and arteriovenous fistula. In the renal cell carcinoma group, 3 patients had stage I, 7 patients had stage II, and 3 patients had stage III disease. Sizes of renal cell carcinoma masses were between 23 mm to 60 mm (mean, 36 mm). Vascular invasion was shown in 2 renal cell carcinoma patients. Collecting system invasion was identified in 11 of 13 renal cell patients. These radiologic findings were confirmed with surgical specimens. Three-dimensional CT and 3D-CTA are non-invasive, effective imaging techniques for the preoperative evaluation of renal masses.

  11. Accurate heterogeneous dose calculation for lung cancer patients without high‐resolution CT densities

    Science.gov (United States)

    Li, Jonathan G.; Liu, Chihray; Olivier, Kenneth R.; Dempsey, James F.

    2009-01-01

    The aim of this study was to investigate the relative accuracy of megavoltage photon‐beam dose calculations employing either five bulk densities or independent voxel densities determined by calibration of the CT Houndsfield number. Full‐resolution CT and bulk density treatment plans were generated for 70 lung or esophageal cancer tumors (66 cases) using a commercial treatment planning system with an adaptive convolution dose calculation algorithm (Pinnacle3, Philips Medicals Systems). Bulk densities were applied to segmented regions. Individual and population average densities were compared to the full‐resolution plan for each case. Monitor units were kept constant and no normalizations were employed. Dose volume histograms (DVH) and dose difference distributions were examined for all cases. The average densities of the segmented air, lung, fat, soft tissue, and bone for the entire set were found to be 0.14, 0.26, 0.89, 1.02, and 1.12 g/cm3, respectively. In all cases, the normal tissue DVH agreed to better than 2% in dose. In 62 of 70 DVHs of the planning target volume (PTV), agreement to better than 3% in dose was observed. Six cases demonstrated emphysema, one with bullous formations and one with a hiatus hernia having a large volume of gas. These required the additional assignment of density to the emphysemic lung and inflammatory changes to the lung, the regions of collapsed lung, the bullous formations, and the hernia gas. Bulk tissue density dose calculation provides an accurate method of heterogeneous dose calculation. However, patients with advanced emphysema may require high‐resolution CT studies for accurate treatment planning. PACS number: 87.53.Tf

  12. Availability of perfluoroctylbromide (PFOB) emulsion used as agent in the liver tumor imaging of computed tomography (CT)

    International Nuclear Information System (INIS)

    Ozawa, Takachika

    1986-01-01

    We carried out a fundamental study on the availability of perfluoroctylbromide (PFOB) emulsion used as an agent in the liver tumor imaging of computed tomography (CT). For this study, we used emulsified yolk phospolipid as a surfactant for PFOB emulsion because it is generally considered to have higher safety relative to the administration to the humans. In the rabbits' liver tumor model in which VX 2 tumor cell was implanted into their livers, we observed increases in the CT values of the livers when 5 to 10 ml/kg of PFOB emulsion (20 % w/v) was administered into the vein, and also ringlike enhancement and increases in the CT values on the tumor rim when 20 ml/kg of PFOB emulsion was administered. In addition, in the chemical analysis of a gas chromatography, we also observed significant increases in the PFOB concentration on the tumor rim, compared with those of normal liver parenchyma, when 20 ml/kg of PFOB emulsion was given. In the finding of CT values in the human liver tumor by means of organ perfusion system, we recognized increases in the CT values (induced by the accumulation of PFOB emulsion) on the rim of the metastatic tumor of colon cancer. These results suggest that PFOB emulsion has certain availability as an agent for the liver tumor imaging of computed tomography (CT). (author)

  13. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... vessels. CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT is less sensitive to patient movement ...

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... vessels. CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT is less sensitive to patient movement ...

  15. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... vessels. CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT is less sensitive to patient movement ...

  16. Dynamic CT myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Caruso, Damiano; Eid, Marwen; Schoepf, U. Joseph; Jin, Kwang Nam; Varga-Szemes, Akos; Tesche, Christian; Mangold, Stefanie

    2016-01-01

    Highlights: • CT myocardial perfusion provides functional assessment of the myocardium. • CCTA is limited in determining the hemodynamic significance of coronary stenosis. • CT-MPI can accurately detect hemodynamically significant coronary artery stenosis. - Abstract: Non-invasive cardiac imaging has rapidly evolved during the last decade due to advancements in CT based technologies. Coronary CT angiography has been shown to reliably assess coronary anatomy and detect high risk coronary artery disease. However, this technique is limited to anatomical assessment, thus non-invasive techniques for functional assessment of the heart are necessary. CT myocardial perfusion is a new CT based technique that provides functional assessment of the myocardium and allows for a comprehensive assessment of coronary artery disease with a single modality when combined with CTA. This review aims to discuss dynamic CT myocardial perfusion as a new technique in the assessment of CAD.

  17. Brain tumor and CT, 1

    International Nuclear Information System (INIS)

    Suzuki, Nobuyuki; Katada, Kazuhiro; Shinomiya, Youichi; Sano, Hirotoshi; Kanno, Tetsuo

    1981-01-01

    It is very important for a neurosurgeon to know the consistency of a brain tumor preoperatively, since the information which is of much use in indicating the likely difficulty of the operation, which operative tools should be selected, the amount of bleeding to be expected from the tumor, and so on. The authors, therefore, tried to evaluate the consistency of brain tumors preoperatively 27 cases in which the margin of the tumor was made clear with a homogeneous stain were studied concerning the relationship between the tumor consistency and the CT findings. The results are as follows: 1) A higher CT number on a plain CT indicated a harder consistency of the tumor. 2) A lesser contrast index (CT number on enhancement CT/CT number on plain CT) showed a harder consistency of the tumor. (author)

  18. Dynamic CT myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Caruso, Damiano [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiological Sciences, Oncological and Pathological Sciences, University of Rome “Sapienza”, Latina (Italy); Eid, Marwen [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States); Jin, Kwang Nam [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiology, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul (Korea, Republic of); Varga-Szemes, Akos [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Tesche, Christian [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Cardiology and Intensive Care Medicine, Heart Center Munich-Bogenhausen, Munich (Germany); Mangold, Stefanie [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, Tuebingen (Germany); and others

    2016-10-15

    Highlights: • CT myocardial perfusion provides functional assessment of the myocardium. • CCTA is limited in determining the hemodynamic significance of coronary stenosis. • CT-MPI can accurately detect hemodynamically significant coronary artery stenosis. - Abstract: Non-invasive cardiac imaging has rapidly evolved during the last decade due to advancements in CT based technologies. Coronary CT angiography has been shown to reliably assess coronary anatomy and detect high risk coronary artery disease. However, this technique is limited to anatomical assessment, thus non-invasive techniques for functional assessment of the heart are necessary. CT myocardial perfusion is a new CT based technique that provides functional assessment of the myocardium and allows for a comprehensive assessment of coronary artery disease with a single modality when combined with CTA. This review aims to discuss dynamic CT myocardial perfusion as a new technique in the assessment of CAD.

  19. Comparison of SPECT/CT, MRI and CT in diagnosis of skull base bone invasion in nasopharyngeal carcinoma.

    Science.gov (United States)

    Zhang, Shu-xu; Han, Peng-hui; Zhang, Guo-qian; Wang, Rui-hao; Ge, Yong-bin; Ren, Zhi-gang; Li, Jian-sheng; Fu, Wen-hai

    2014-01-01

    Early detection of skull base invasion in nasopharyngeal carcinoma (NPC) is crucial for correct staging, assessing treatment response and contouring the tumor target in radiotherapy planning, as well as improving the patient's prognosis. To compare the diagnostic efficacy of single photon emission computed tomography/computed tomography (SPECT/CT) imaging, magnetic resonance imaging (MRI) and computed tomography (CT) for the detection of skull base invasion in NPC. Sixty untreated patients with histologically proven NPC underwent SPECT/CT imaging, contrast-enhanced MRI and CT. Of the 60 patients, 30 had skull base invasion confirmed by the final results of contrast-enhanced MRI, CT and six-month follow-up imaging (MRI and CT). The diagnostic efficacy of the three imaging modalities in detecting skull base invasion was evaluated. The rates of positive findings of skull base invasion for SPECT/CT, MRI and CT were 53.3%, 48.3% and 33.3%, respectively. The sensitivity, specificity and accuracy were 93.3%, 86.7% and 90.0% for SPECT/CT fusion imaging, 96.7%, 100.0% and 98.3% for contrast-enhanced MRI, and 66.7%, 100.0% and 83.3% for contrast-enhanced CT. MRI showed the best performance for the diagnosis of skull base invasion in nasopharyngeal carcinoma, followed closely by SPECT/CT. SPECT/CT had poorer specificity than that of both MRI and CT, while CT had the lowest sensitivity.

  20. PET/CT and radiotherapy

    International Nuclear Information System (INIS)

    Messa, C.; CNR, Milano; S. Gerardo Hospital, Monza; Di Muzio, N.; Picchio, M.; Bettinardi, V.; Gilardi, M.C.; CNR, Milano; San Raffaele Scientific Institute, Milano; Fazio, F.; CNR, Milano; San Raffaele Scientific Institute, Milano; San Raffaele Scientific Institute, Milano

    2006-01-01

    This article reviews the state of the art of PET/CT applications in radiotherapy, specifically its use in disease staging, patient selection, treatment planning and treatment evaluation. Diseases for which radiotherapy with radical intent is indicated will be considered, as well as those in which PET/CT may actually change the course of disease. The methodological and technological aspects of PET/CT in radiotherapy are discussed, focusing on the problem of target volume definition with CT and PET functional imaging and the problem of tumor motion with respect to imaging and dose delivery

  1. Slice sensitivity profiles and pixel noise of multi-slice CT in comparison with single-slice CT

    International Nuclear Information System (INIS)

    Schorn, C.; Obenauer, S.; Funke, M.; Hermann, K.P.; Kopka, L.; Grabbe, E.

    1999-01-01

    Purpose: Presentation and evaluation of slice sensitivity profile and pixel noise of multi-slice CT in comparison to single-slice CT. Methods: Slice sensitivity profiles and pixel noise of a multi-slice CT equiped with a 2D matrix detector array and of a single-slice CT were evaluated in phantom studies. Results: For the single-slice CT the width of the slice sensitivity profiles increased with increasing pitch. In spite of a much higher table speed the slice sensitivity profiles of multi-slice CT were narrower and did not increase with higher pitch. Noise in single-slice CT was independent of pitch. For multi-slice CT noise increased with higher pitch and for the higher pitch decreased slightly with higher detector row collimation. Conclusions: Multi-slice CT provides superior z-resolution and higher volume coverage speed. These qualities fulfill one of the prerequisites for improvement of 3D postprocessing. (orig.) [de

  2. Adenocarcinoma Prostate With Neuroendocrine Differentiation: Potential Utility of 18F-FDG PET/CT and 68Ga-DOTANOC PET/CT Over 68Ga-PSMA PET/CT.

    Science.gov (United States)

    Parida, Girish Kumar; Tripathy, Sarthak; Datta Gupta, Shreya; Singhal, Abhinav; Kumar, Rakesh; Bal, Chandrasekhar; Shamim, Shamim Ahmed

    2018-04-01

    Ga-PSMA PET/CT is the upcoming imaging modality for staging, restaging and response assessment of prostate cancer. However, due to neuroendocrine differentiation in some of patients with prostate cancer, they express somatostatin receptors instead of prostate specific membrane antigen. This can be exploited and other modalities like Ga-DOTANOC PET/CT and F-FDG PET/CT should be used in such cases for guiding management. We hereby discuss a similar case of 67-year-old man of adenocarcinoma prostate with neuroendocrine differentiation, which shows the potential pitfall of Ga-PSMA PET/CT imaging and benefit of Ga-DOTANOC PET/CT and F-FDG PET/CT in such cases.

  3. NMR-CT scanner

    International Nuclear Information System (INIS)

    Kose, Katsumi; Sato, Kozo; Sugimoto, Hiroshi; Sato, Masataka.

    1983-01-01

    A brief explanation is made on the imaging methods for a practical diagnostic NMR-CT scanner : A whole-body NMR-CT scanner utilizing a resistive magnet has been developed by Toshiba in cooperation with the Institute for Solid State Physics, the University of Tokyo. Typical NMR-CT images of volunteers and patients obtained in the clinical experiments using this device are presented. Detailed specifications are also shown about the practical NMR-CTs which are to be put on the market after obtaining the government approval. (author)

  4. CT and HR-CT of exogenous allergic alveolitis

    International Nuclear Information System (INIS)

    Lederer, A.; Kullnig, P.; Pongratz, M.

    1992-01-01

    The CT changes on conventional and high resolution CT in 14 patients with exogeneous allergic alveolitis (EAA) were analysed retrospectively. There were 8 patients with clinically subacute disease, 5 patients in a chronic stage and 1 patient with acute EAA. The appearances and their distribution were examined. Seven of the 8 patients in the subacute stage showed a ground glass pattern and multiple nodules of less than 2 mm. All patients in the chronic stage showed a combination of fine infiltrates, small nodules and irregular linear densities; distortion of the pulmonary pattern was present in 3 cases. The patient with acute EAA showed diffuse dense areas of consolidation in both lungs as well as multiple nodules and a ground glass pattern. The CT appearances of EAA correspond with the basic micropathology and, within the clinical context, permit diagnostic classification. (orig.) [de

  5. Experimental Rock Deformation under micro-CT: ERDμ

    Science.gov (United States)

    Tisato, Nicola; Zhao, Qi; Biryukov, Anton; Grasselli, Giovanni

    2015-04-01

    Typically, the static elastic moduli of a rock differ from the corresponding dynamic rock-moduli. Such frequency-dependent characteristic, called modulus dispersion, implies also velocity dispersion (i.e. Vp- and Vs-dispersion). Velocity dispersion can be seen, in fact, as the result of a viscoelastic response of the geo-material to the externally imposed stress (e.g. seismic wave). Viscoelasticity can be conveniently expressed as attenuation (1/Q), which describes the loss of elastic energy for each stress cycle and comprises the measurement of the complex elastic modulus. As 1/Q at frequencies important seismic attribute as it can aid the subsurface imaging accuracy. For instance, the study of 1/Q is fundamental for the oil and gas industry as valuable natural resources, such as oil-sands or gas-shales, exhibit significant attenuation (e.g. 1/Q ~ 0.3 at 1 Hz), or for volcanic and earthquake related studies as fluids are often involved in those natural processes. In the last five years, employing the Broad Band Attenuation Vessel (BBAV), the attenuation of partially saturated rocks has been investigated along with the fluid pressure transient caused by a sudden increase of stress. In particular, those studies shed light on the relationships between 1/Q and i) saturation, ii) confining pressure, and iii) strain. The combination of laboratory and numerical results helped demonstrating that wave induced fluid flow (WIFF) on the mesoscopic scale is responsible for the large and frequency-dependent attenuation observed in the laboratory measurements of a partially saturated sandstone. However, these studies lay bare limitations: the behavior of attenuation as a function of i) the distribution of fluids in the pore space and ii) the role of dissolution-precipitation of new mineral phases are still unclear. For instance, when CO2 is injected in the Earth's crust to pursuit carbon sequestration it would be extremely useful understanding the impact of the gas

  6. Coronary calcium screening with dual-source CT: reliability of ungated, high-pitch chest CT in comparison with dedicated calcium-scoring CT

    Energy Technology Data Exchange (ETDEWEB)

    Hutt, Antoine; Faivre, Jean-Baptiste; Remy, Jacques; Remy-Jardin, Martine [CHRU et Universite de Lille, Department of Thoracic Imaging, Hospital Calmette (EA 2694), Lille (France); Duhamel, Alain; Deken, Valerie [CHRU et Universite de Lille, Department of Biostatistics (EA 2694), Lille (France); Molinari, Francesco [Centre Hospitalier General de Tourcoing, Department of Radiology, Tourcoing (France)

    2016-06-15

    To investigate the reliability of ungated, high-pitch dual-source CT for coronary artery calcium (CAC) screening. One hundred and eighty-five smokers underwent a dual-source CT examination with acquisition of two sets of images during the same session: (a) ungated, high-pitch and high-temporal resolution acquisition over the entire thorax (i.e., chest CT); (b) prospectively ECG-triggered acquisition over the cardiac cavities (i.e., cardiac CT). Sensitivity and specificity of chest CT for detecting positive CAC scores were 96.4 % and 100 %, respectively. There was excellent inter-technique agreement for determining the quantitative CAC score (ICC = 0.986). The mean difference between the two techniques was 11.27, representing 1.81 % of the average of the two techniques. The inter-technique agreement for categorizing patients into the four ranks of severity was excellent (weighted kappa = 0.95; 95 % CI 0.93-0.98). The inter-technique differences for quantitative CAC scores did not correlate with BMI (r = 0.05, p = 0.575) or heart rate (r = -0.06, p = 0.95); 87.2 % of them were explained by differences at the level of the right coronary artery (RCA: 0.8718; LAD: 0.1008; LCx: 0.0139; LM: 0.0136). Ungated, high-pitch dual-source CT is a reliable imaging mode for CAC screening in the conditions of routine chest CT examinations. (orig.)

  7. Clinical applications of SPECT-CT

    Energy Technology Data Exchange (ETDEWEB)

    Ahmadzadehfar, Hojjat; Biersack, Hans-Juergen (eds.) [University Hospital Bonn (Germany). Dept. of Nuclear Medicine

    2014-06-01

    Covers the full spectrum of clinical applications of SPECT/CT in diagnosis of benign and malignant diseases. Includes chapters on the use of SPECT/CT for dosimetry and for therapy planning. Completely up to date. Many helpful illustrations. SPECT/CT cameras have considerably improved diagnostic accuracy in recent years. Such cameras allow direct correlation of anatomic and functional information, resulting in better localization and definition of scintigraphic findings. In addition to this anatomic referencing, CT coregistration provides superior quantification of radiotracer uptake based on the attenuation correction capabilities of CT. Useful applications of SPECT/CT have been identified not only in oncology but also in other specialties such as orthopedics and cardiology. This book covers the full spectrum of clinical applications of SPECT/CT in diagnosis and therapy planning of benign and malignant diseases. Opening chapters discuss the technology and physics of SPECT/CT and its use for dosimetry. The role of SPECT/CT in the imaging of a range of pathologic conditions is then addressed in detail. Applications covered include, among others, imaging of the thyroid, bone, and lungs, imaging of neuroendocrine tumors, cardiac scintigraphy, and sentinel node scintigraphy. Individual chapters are also devoted to therapy planning in selective internal radiation therapy of liver tumors and bremsstrahlung SPECT/CT. Readers will find this book to be an essential and up-to-date source of information on this invaluable hybrid imaging technique.

  8. Thoracic textilomas: CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Machado, Dianne Melo; Zanetti, Glaucia; Araujo Neto, Cesar Augusto; Nobre, Luiz Felipe; Meirelles, Gustavo de Souza Portes; Silva, Jorge Luiz Pereira e; Guimaraes, Marcos Duarte; Escuissato, Dante Luiz; Souza Junior, Arthur Soares; Hochhegger, Bruno; Marchiori, Edson, E-mail: edmarchiori@gmail.com [Hospital Universitario Antonio Pedro (HUAP/UFF), Niteroi, RJ (Brazil)

    2014-09-15

    Objective: the aim of this study was to analyze chest CT scans of patients with thoracic textiloma. Methods: this was a retrospective study of 16 patients (11 men and 5 women) with surgically confirmed thoracic textiloma. The chest CT scans of those patients were evaluated by two independent observers, and discordant results were resolved by consensus. Results: the majority (62.5%) of the textilomas were caused by previous heart surgery. The most common symptoms were chest pain (in 68.75%) and cough (in 56.25%). In all cases, the main tomographic finding was a mass with regular contours and borders that were well-defined or partially defined. Half of the textilomas occurred in the right hemithorax and half occurred in the left. The majority (56.25%) were located in the lower third of the lung. The diameter of the mass was ≤ 10 cm in 10 cases (62.5%) and > 10 cm in the remaining 6 cases (37.5%). Most (81.25%) of the textilomas were heterogeneous in density, with signs of calcification, gas, radiopaque marker, or sponge-like material. Peripheral expansion of the mass was observed in 12 (92.3%) of the 13 patients in whom a contrast agent was used. Intraoperatively, pleural involvement was observed in 14 cases (87.5%) and pericardial involvement was observed in 2 (12.5%). Conclusions: it is important to recognize the main tomographic aspects of thoracic textilomas in order to include this possibility in the differential diagnosis of chest pain and cough in patients with a history of heart or thoracic surgery, thus promoting the early identification and treatment of this postoperative complication. (author)

  9. Comparison of the 68Ga-DOTATATA PET/CT, FDG PET/CT, and MIBG SPECT/CT in the Evaluation of Suspected Primary Pheochromocytomas and Paragangliomas.

    Science.gov (United States)

    Jing, Hongli; Li, Fang; Wang, Ling; Wang, Zhenghua; Li, Wei; Huo, Li; Zhang, Jingjing

    2017-07-01

    Anatomical imaging modalities including CT and MRI are the mainstay of evaluation of primary pheochromocytoma or paraganglioma. However, nuclear medicine imaging is frequently necessary to determine the nature of the lesions. The purpose of this investigation is to assess which commonly used nuclear medicine modality might have a better diagnostic value in this clinical setting. Eight patients who had been suspected of having either primary pheochromocytoma or primary paraganglioma and 1 patient with known pheochromocytoma were included in the analysis. Among the 8 patients without known diagnosis, 7 had been suggested by anatomical imaging modalities, whereas one of them presented with initial negative anatomical imaging interpretation. All of 9 patients underwent Ga-DOTATATA PET/CT, FDG PET/CT, and MIBG SPECT/CT for further evaluation. The imaging findings were compared with postsurgical pathology and follow-up. Both Ga-DOTATATA PET/CT and MIBG SPECT/CT accurately identified 9 primary tumors, whereas FDG PET/CT showed increased activity in 8 of 9 primary tumors. Both Ga-DOTATATA and FDG PET/CT are able to detect associated extra-adrenal lesions not shown on MIBG study in patients with multiple endocrine neoplasia syndrome. Ga-DOTATATA PET/CT could be the nuclear medicine imaging choice to evaluate suspected primary pheochromocytoma or paraganglioma, especially in the situation of multiple endocrine neoplasia syndrome.

  10. CT findings of infant epilepsy

    International Nuclear Information System (INIS)

    Hojoh, Hiroatsu; Kataoka, Kenkichi; Nakagawa, Yoshihiro; Nakano, Shozo; Tomita, Yutaka.

    1982-01-01

    CT diagnosis of infantile epilepsy was evaluated. High incidence of abnormal CT findings in infantile spasms and Lennox-Gastaut syndrome was same as in other reports. Comparison between CT findings and neurological complications and that between CT findings and electroencephalogram findings revealed a stronger relationship existing in the former. This suggested that CT is more useful as a measure to detect underlying diseases which are due to organic change of the brain to cause epilepsy, rather than as that to disclose epileptic primary lesions of functional change. (Ueda, J.)

  11. CT of thymoma

    International Nuclear Information System (INIS)

    Sone, Shusuke; Higashihara, Tokuro; Morimoto, Shizuo; Ikezoe, Junpei; Arisawa, Jun

    1982-01-01

    Based on 17 patients with thymoma (8 with myasthenia gravis and 9 free from it); 1. The effectiveness of CT, conventional radiography and pneumomediastinography in the detection of thymomas was determined and the results compared. 2. The CT findings of thymomas were discussed and the CT features which seemed to suggest malignant thymomas were evaluated. The results were as follows: 1. Of the 17 cases with thymomas, 13 were diagnosed from p-a films, 13 from lateral films, and 16 from CT. Of the 16 thymomas, 14 were diagnosed from lateral tomography. Mass densities were shown in all 15 cases in which pneumomediastinography were performed. 2. Benign thymomas showed round or oval smoothly marginated mass. The fatty plane between the mass and the mediastinal structures was nicely preserved. 3. Malignant thymoma frequently showed a plaque-like mass with more or less irregular or lobulated contoures with obliteration of the fatty planes of the cardiovascular structures. Tumor calcification was shown in 4 of 10 malignant thymomas. 4. Slight tumor invasion to the mediastinal pleura and lung was difficult to predict from the CT images. (author)

  12. F-FDG PET/CT (PET/CT) influences management in patients with known or suspected pancreatic cancer

    International Nuclear Information System (INIS)

    Barber, Thomas W.; Kalff, Victor; Cherk, Martin H.; Yap, Kenneth SK.; Evans, Peter; Kelly, Michael J.

    2009-01-01

    Full text: Objective: To assess the impact on clinical management of PET/CT in patients with known or suspected pancreatic cancer. Methods: Between April 2006 and September 2008,25 PET/CT scans were performed using a dedicated PET/CT (22 scans) or a coincidence hybrid PET/CT camera (3 scans) in 23 patients with known or suspected pancreatic cancer. 17 scans were performed for initial evaluation and 8 for restaging of disease. The pre-PET/CT management plan and for intent were prospectively recorded in all cases. The post-PET/CT management plan was determined from the medical record and for discussions with treating clinicians. The impact of PET/CT on management was classified as High, Medium, Low or None, defined using ANZAPNM PET data collection project criteria. Follow-up was used to reconcile any discordance between PET/CT and conventional imaging. Results: Overall, PET/CT management impact was classified as high (n equal 7), medium (n equal 4), low (n equal 10) or none (n equal 4). Impact was either high or medium in l l/25 patients (44%) (95% confidence interval; 24 - 64%). Impact was high in 4/17 patients imaged for initial evaluation, predominantly by clarifying equivocal lesions on conventional imaging. In restaged patients, PET/CT impact was high in 3/8, and it correctly modified disease extent in 5/8. In the 16 discordant studies, PET/CT assessment was correct in 10, conventional imaging in 4 and there was insufficient information in 2. Conclusion: PET/CT has high or medium management impact in 44% of patients imaged for known or suspected pancreatic cancer, more commonly during restaging. Discordant PET/CT results were usually correct.

  13. SedCT: MATLAB™ tools for standardized and quantitative processing of sediment core computed tomography (CT) data collected using a medical CT scanner

    Science.gov (United States)

    Reilly, B. T.; Stoner, J. S.; Wiest, J.

    2017-08-01

    Computed tomography (CT) of sediment cores allows for high-resolution images, three-dimensional volumes, and down core profiles. These quantitative data are generated through the attenuation of X-rays, which are sensitive to sediment density and atomic number, and are stored in pixels as relative gray scale values or Hounsfield units (HU). We present a suite of MATLAB™ tools specifically designed for routine sediment core analysis as a means to standardize and better quantify the products of CT data collected on medical CT scanners. SedCT uses a graphical interface to process Digital Imaging and Communications in Medicine (DICOM) files, stitch overlapping scanned intervals, and create down core HU profiles in a manner robust to normal coring imperfections. Utilizing a random sampling technique, SedCT reduces data size and allows for quick processing on typical laptop computers. SedCTimage uses a graphical interface to create quality tiff files of CT slices that are scaled to a user-defined HU range, preserving the quantitative nature of CT images and easily allowing for comparison between sediment cores with different HU means and variance. These tools are presented along with examples from lacustrine and marine sediment cores to highlight the robustness and quantitative nature of this method.

  14. CT in normal pressure hydrocephalus. Correlation between CT and clinical response to shunting

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, K.; Nogaki, H.; Noda, M.; Kusunoki, T.; Tamaki, N. (Kobe Univ. (Japan). School of Medicine)

    1981-02-01

    CT scans were obtained on 33 patients (age 73y. to 31y.) with the diagnosis of normal pressure hydrocephalus. In each case, the diagnosis was made on the basis of the symptoms, CT and cisternographic findings. Underlying diseases of normal pressure hydrocephalus are ruptured aneurysms (21 cases), arteriovenous malformations (2 cases), head trauma (1 case), cerebrovascular accidents (1 case) and idiopathie (8 cases). Sixteen of 33 patients showed marked improvement, five, moderate or minimal improvement, and twelve, no change. The results were compared with CT findings and clinical response to shunting. CT findings were classified into five types, bases on the degree of periventricular hypodensity (P.V.H.), the extent of brain damage by underlying diseases, and the degree of cortical atrophy. In 17 cases of type (I), CT shows the presence of P.V.H. with or without minimal frontal lobe damage and no cortical atrophy. The good surgical improvements were achieved in all cases of type (I) by shunting. In 4 cases of type (II), CT shows the presence of P.V.H. and severe brain damage without cortical atrophy. The fair clinical improvements were achieved in 2 cases (50%) by shunting. In one case of type (III), CT shows the absence of P.V.H. without brain damage nor cortical atrophy. No clinical improvement was obtained by shunting in this type. In 9 cases of type (IV) with mild cortical atrophy, the fair clinical improvement was achieved in two cases (22%) and no improvement in 7 cases. In 2 cases of type (V) with moderate or marked cortical atrophy, no clinical improvement was obtained by shunting. In conclusion, it appeared from the present study that there was a good correlation between the result of shunting and the type of CT, and clinical response to shunting operation might be predicted by classification of CT findings.

  15. Estimation of skull table thickness with clinical CT and validation with microCT.

    Science.gov (United States)

    Lillie, Elizabeth M; Urban, Jillian E; Weaver, Ashley A; Powers, Alexander K; Stitzel, Joel D

    2015-01-01

    Brain injuries resulting from motor vehicle crashes (MVC) are extremely common yet the details of the mechanism of injury remain to be well characterized. Skull deformation is believed to be a contributing factor to some types of traumatic brain injury (TBI). Understanding biomechanical contributors to skull deformation would provide further insight into the mechanism of head injury resulting from blunt trauma. In particular, skull thickness is thought be a very important factor governing deformation of the skull and its propensity for fracture. Current computed tomography (CT) technology is limited in its ability to accurately measure cortical thickness using standard techniques. A method to evaluate cortical thickness using cortical density measured from CT data has been developed previously. This effort validates this technique for measurement of skull table thickness in clinical head CT scans using two postmortem human specimens. Bone samples were harvested from the skulls of two cadavers and scanned with microCT to evaluate the accuracy of the estimated cortical thickness measured from clinical CT. Clinical scans were collected at 0.488 and 0.625 mm in plane resolution with 0.625 mm thickness. The overall cortical thickness error was determined to be 0.078 ± 0.58 mm for cortical samples thinner than 4 mm. It was determined that 91.3% of these differences fell within the scanner resolution. Color maps of clinical CT thickness estimations are comparable to color maps of microCT thickness measurements, indicating good quantitative agreement. These data confirm that the cortical density algorithm successfully estimates skull table thickness from clinical CT scans. The application of this technique to clinical CT scans enables evaluation of cortical thickness in population-based studies. © 2014 Anatomical Society.

  16. CT-based virtual tracheobronchoscopy in children - comparison with axial CT and multiplanar reconstruction: preliminary results

    International Nuclear Information System (INIS)

    Sorantin, Erich; Lindbichler, Franz; Eber, Ernst; Schimpl, Guenther

    2002-01-01

    Background: 3D post-processing of spiral-CT (S-CT) data using perspective projection allows the generation of virtual views similar to endoscopy. Objective: To evaluate whether simultaneous reading of axial S-CT, multiplanar reconstruction (MPR) and virtual tracheobronchoscopy (VTB) is more precise and accurate than reading of axial S-CT and MPR alone in paediatric patients. Materials and methods: S-CT studies of 15 symptomatic and 4 normal patients were investigated. Two radiologists independently read two sets of images for airway abnormalities: first axial CT and MPR, followed by axial CT, MPR and VTB. A final decision was later made by consensus. All results were compared to fibre-optic bronchoscopy (FTB). Interobserver agreement was used as an indicator of precision for the display technique used. Results: At reading of axial S-CT and MPR an interobserver agreement of 89.5% (κ=0.776, P<0.00103) was found. Based on the consensus decision, a diagnostic accuracy of 89.5% at a sensitivity 86.6% and specificity of 100% (κ=0.776, 95% CI 0.491-1.062, P<0.00103) was achieved. At reporting on axial S-CT, MPR and VTB, all cases were classified correctly by both readers, indicating 100% accuracy, interobserver agreement, sensitivity and specificity (κ=1.00, 95% CI 1.0-1.0, P<0.000258). Conclusions: The simultaneous display of axial S-CT, MPR and VTB raises the precision, accuracy and sensitivity of radiological reports. (orig.)

  17. TU-G-BRA-02: Can We Extract Lung Function Directly From 4D-CT Without Deformable Image Registration?

    Energy Technology Data Exchange (ETDEWEB)

    Kipritidis, J; Woodruff, H; Counter, W; Keall, P [University of Sydney, Sydney, NSW (Australia); Hofman, M; Siva, S; Callahan, J; Le Roux, P [Peter MacCallum Cancer Centre, Melbourne, VIC (Australia); Hardcastle, N [Royal North Shore Hospital, Sydney, NSW (Australia)

    2015-06-15

    Purpose: Dynamic CT ventilation imaging (CT-VI) visualizes air volume changes in the lung by evaluating breathing-induced lung motion using deformable image registration (DIR). Dynamic CT-VI could enable functionally adaptive lung cancer radiation therapy, but its sensitivity to DIR parameters poses challenges for validation. We hypothesize that a direct metric using CT parameters derived from Hounsfield units (HU) alone can provide similar ventilation images without DIR. We compare the accuracy of Direct and Dynamic CT-VIs versus positron emission tomography (PET) images of inhaled {sup 68}Ga-labelled nanoparticles (‘Galligas’). Methods: 25 patients with lung cancer underwent Galligas 4D-PET/CT scans prior to radiation therapy. For each patient we produced three CT- VIs. (i) Our novel method, Direct CT-VI, models blood-gas exchange as the product of air and tissue density at each lung voxel based on time-averaged 4D-CT HU values. Dynamic CT-VIs were produced by evaluating: (ii) regional HU changes, and (iii) regional volume changes between the exhale and inhale 4D-CT phase images using a validated B-spline DIR method. We assessed the accuracy of each CT-VI by computing the voxel-wise Spearman correlation with free-breathing Galligas PET, and also performed a visual analysis. Results: Surprisingly, Direct CT-VIs exhibited better global correlation with Galligas PET than either of the dynamic CT-VIs. The (mean ± SD) correlations were (0.55 ± 0.16), (0.41 ± 0.22) and (0.29 ± 0.27) for Direct, Dynamic HU-based and Dynamic volume-based CT-VIs respectively. Visual comparison of Direct CT-VI to PET demonstrated similarity for emphysema defects and ventral-to-dorsal gradients, but inability to identify decreased ventilation distal to tumor-obstruction. Conclusion: Our data supports the hypothesis that Direct CT-VIs are as accurate as Dynamic CT-VIs in terms of global correlation with Galligas PET. Visual analysis, however, demonstrated that different CT

  18. TU-G-BRA-02: Can We Extract Lung Function Directly From 4D-CT Without Deformable Image Registration?

    International Nuclear Information System (INIS)

    Kipritidis, J; Woodruff, H; Counter, W; Keall, P; Hofman, M; Siva, S; Callahan, J; Le Roux, P; Hardcastle, N

    2015-01-01

    Purpose: Dynamic CT ventilation imaging (CT-VI) visualizes air volume changes in the lung by evaluating breathing-induced lung motion using deformable image registration (DIR). Dynamic CT-VI could enable functionally adaptive lung cancer radiation therapy, but its sensitivity to DIR parameters poses challenges for validation. We hypothesize that a direct metric using CT parameters derived from Hounsfield units (HU) alone can provide similar ventilation images without DIR. We compare the accuracy of Direct and Dynamic CT-VIs versus positron emission tomography (PET) images of inhaled "6"8Ga-labelled nanoparticles (‘Galligas’). Methods: 25 patients with lung cancer underwent Galligas 4D-PET/CT scans prior to radiation therapy. For each patient we produced three CT- VIs. (i) Our novel method, Direct CT-VI, models blood-gas exchange as the product of air and tissue density at each lung voxel based on time-averaged 4D-CT HU values. Dynamic CT-VIs were produced by evaluating: (ii) regional HU changes, and (iii) regional volume changes between the exhale and inhale 4D-CT phase images using a validated B-spline DIR method. We assessed the accuracy of each CT-VI by computing the voxel-wise Spearman correlation with free-breathing Galligas PET, and also performed a visual analysis. Results: Surprisingly, Direct CT-VIs exhibited better global correlation with Galligas PET than either of the dynamic CT-VIs. The (mean ± SD) correlations were (0.55 ± 0.16), (0.41 ± 0.22) and (0.29 ± 0.27) for Direct, Dynamic HU-based and Dynamic volume-based CT-VIs respectively. Visual comparison of Direct CT-VI to PET demonstrated similarity for emphysema defects and ventral-to-dorsal gradients, but inability to identify decreased ventilation distal to tumor-obstruction. Conclusion: Our data supports the hypothesis that Direct CT-VIs are as accurate as Dynamic CT-VIs in terms of global correlation with Galligas PET. Visual analysis, however, demonstrated that different CT-VI algorithms

  19. CT of splenic trauma

    International Nuclear Information System (INIS)

    Griffiths, B.G.; Federle, M.P.; Minagi, H.; Jeffrey, R.B.

    1986-01-01

    Fifty-five consecutive cases of surgically proved splenic injuries were evaluated by CT. CT correctly identified 54 splenic injuries, with one false-negative and three false-positive studies. In the single false-negative study and in two of the three false-positive studies, CT correctly indicated the presence of a large hemoperitoneum and other abdominal visceral lacerations and so correctly indicated the need for surgery. Of the 55 proved cases of splenic injury, CT revealed hemoperitoneum in 54 (99%), perisplenic clot in 47 (85%), splenic laceration in 39 (71%), and subcapsular hematoma in 13 (24%). Perisplenic clot can be distinguished from lysed blood in the peritoneal cavity and is a sensitive and specific sign of splenic trauma, even in the absence of visible splenic laceration. The authors conclude that CT is highly reliable means of evaluating splenic trauma

  20. Value of CT scan in synovial diseases

    Energy Technology Data Exchange (ETDEWEB)

    Tamisier, J.N.; Regent, D.; Thomas, P.; Pere, P.; Gaucher, A.; Capesius, P.

    1986-02-01

    The authors have developed a technique of CT arthroscan which, by the use of a gas or opaque contrast medium, is able to demonstrate the synovial structures of the knee, the shoulder and the hip. Among the essential indications, they include the demonstration of neoplasia of the synovium and the evaluation of the pannus in rheumatoid arthritis. Their secondary indications include the demonstration of fluid effusions in the hip, the precise evaluation of hyperostotic lesions in the same joint, the detection of ossification phenomena in the capsule of the inter-apophyseal joints in ankylosing spondylitis and, in some cases, following negative or doubtful arthrography for the detection of synovial plica. They also recall the usefulness or the arthroscan in the diagnosis of lesions of the labrum glenoidale.

  1. Evaluation of pre and post-operative spinal plain CT and CT-myelography

    International Nuclear Information System (INIS)

    Nagase, Joji; Inoue, Shunichi; Miyasaka, Hitoshi; Kamata, Sakae; Shinohara, Hiroyasu.

    1983-01-01

    Confirmation of the level of scan slices is essential for the CT diagnosis of spinal and spinal-cord diseases. Pre- and postoperative comparison should be made on the same level. For reading of plain CT and CTM, window levels should be identical pre- and postoperatively. Both methods demonstrated the spinal canal, morphology of the spinal cord, and three-Fdimensional pathologic pictures inside and outside the spinal cord. Preoperative CT contributed useful information on the pathologic conditions and selection of surgical procedures and routes. Postoperative plain CT confirmed surgical results, and CTM revealed the spinal cord and the subarachnoid space, as well as the range and degree of decompression from the spinal cord. (Chiba, N.)

  2. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow new CT scanners to obtain multiple slices in a single rotation. These scanners, called "multislice CT" or "multidetector CT," ...

  3. SPECT/CT and pulmonary embolism

    Energy Technology Data Exchange (ETDEWEB)

    Mortensen, Jann [Copenhagen University Hospital, Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark); The Faroese National Hospital, Department of Medicine, Torshavn (Faroe Islands); Gutte, Henrik [Copenhagen University Hospital, Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark); Herlev Hospital, Copenhagen University Hospital, Department of Radiology, Copenhagen (Denmark); University of Copenhagen, Cluster for Molecular Imaging, Faculty of Health Sciences, Copenhagen (Denmark)

    2014-05-15

    Acute pulmonary embolism (PE) is diagnosed either by ventilation/perfusion (V/P) scintigraphy or pulmonary CT angiography (CTPA). In recent years both techniques have improved. Many nuclear medicine centres have adopted the single photon emission CT (SPECT) technique as opposed to the planar technique for diagnosing PE. SPECT has been shown to have fewer indeterminate results and a higher diagnostic value. The latest improvement is the combination of a low-dose CT scan with a V/P SPECT scan in a hybrid tomograph. In a study comparing CTPA, planar scintigraphy and SPECT alone, SPECT/CT had the best diagnostic accuracy for PE. In addition, recent developments in the CTPA technique have made it possible to image the pulmonary arteries of the lungs in one breath-hold. This development is based on the change from a single-detector to multidetector CT technology with an increase in volume coverage per rotation and faster rotation. Furthermore, the dual energy CT technique is a promising modality that can provide functional imaging in combination with anatomical information. Newer high-end CT scanners and SPECT systems are able to visualize smaller subsegmental emboli. However, consensus is lacking regarding the clinical impact and treatment. In the present review, SPECT and SPECT in combination with low-dose CT, CTPA and dual energy CT are discussed in the context of diagnosing PE. (orig.)

  4. Variation in quantitative CT air trapping in heavy smokers on repeat CT examinations

    Energy Technology Data Exchange (ETDEWEB)

    Mets, Onno M.; Gietema, Hester A.; Jong, Pim A. de [University Medical Center Utrecht, Radiology, Heidelberglaan 100, Postbus 85500, Utrecht (Netherlands); Isgum, Ivana; Mol, Christian P. [University Medical Center Utrecht, Image Sciences Institute, Utrecht (Netherlands); Zanen, Pieter [University Medical Center Utrecht, Pulmonology, Utrecht (Netherlands); Prokop, Mathias [Radboud University Nijmegen Medical Centre, Radiology, Nijmegen (Netherlands); University Medical Center Utrecht, Radiology, Heidelberglaan 100, Postbus 85500, Utrecht (Netherlands)

    2012-12-15

    To determine the variation in quantitative computed tomography (CT) measures of air trapping in low-dose chest CTs of heavy smokers. We analysed 45 subjects from a lung cancer screening trial, examined by CT twice within 3 months. Inspiratory and expiratory low-dose CT was obtained using breath hold instructions. CT air trapping was defined as the percentage of voxels in expiratory CT with an attenuation below -856 HU (EXP{sub -856}) and the expiratory to inspiratory ratio of mean lung density (E/I-ratio{sub MLD}). Variation was determined using limits of agreement, defined as 1.96 times the standard deviation of the mean difference. The effect of both lung volume correction and breath hold reproducibility was determined. The limits of agreement for uncorrected CT air trapping measurements were -15.0 to 11.7 % (EXP{sub -856}) and -9.8 to 8.0 % (E/I-ratio{sub MLD}). Good breath hold reproducibility significantly narrowed the limits for EXP{sub -856} (-10.7 to 7.5 %, P = 0.002), but not for E/I-ratio{sub MLD} (-9.2 to 7.9 %, P = 0.75). Statistical lung volume correction did not improve the limits for EXP{sub -856} (-12.5 to 8.8 %, P = 0.12) and E/I-ratio{sub MLD} (-7.5 to 5.8 %, P = 0.17). Quantitative air trapping measures on low-dose CT of heavy smokers show considerable variation on repeat CT examinations, regardless of lung volume correction or reproducible breath holds. (orig.)

  5. Clinical values of CT and dynamic CT in brain infarction

    International Nuclear Information System (INIS)

    Lim, Soo Il; Jang, Do; Seo, Eun Joo; Sohn, Myung Hee; Choi, Ki Chul

    1985-01-01

    With the advent of faster scan time and new computer program, a scanning technique called 'dynamic computed tomography' has become possible. Dynamic computed tomography consisted of performing multiple rapid sequence scans after injection of contrast material. The authors have evaluated the clinical usefulness of computed tomography and dynamic computed tomography of 93 patients with brain infarction and/or ischemia during the period of 17 months from April 1983 to August 1984 in Department of Radiology, Chonbuk National University Hospital. The results were as follows; 1. The age distribution ranged from 18 years to 78 years. Among them the most common age group was between 50 years and 59 years (40.9%). 2. The sites of brain infarction were cerebral lobes (63 cases,68), basal ganglia (15 cases, 16.1%) and multiple sites (6 cases, 6.4%). The common affected site was middle cerebral artery territories. 3. The contrast enhancement of acute infarction was noted in 14 cases (17.5%) which occurred commonly between 3 days and 2 weeks from ictus. 4. The patterns of time-density curve in brain infarction and/or ischemia were as follow: a. Depression of slow wash-in phase was 20 cases (59%). b. Lower peak concentration was 17 cases (50%). c. Lower and delayed peak concentration was 7 cases (21%). d. No definite peak concentration was 6 cases (18%). First three patterns of time-density curve were thought as relatively characteristic curve of brain infarction and/or ischemia. 5. Two cases that showed negative findings on precontrast CT scan appeared to be positive findings as hypodensity on postcontrast CT scan and were confirmed as brain infarction by dynamic CT. 6. The diagnostic entity of dynamic CT scan were as follows; a. large artery thrombotic infarction were 23 cases (58%). b. lacnar infarction were 6 cases (15%). c. ischemia were 5 cases (13%). d. normal were 5 cases (13%). In six cases of lacunar infarction which was double hypodensity on pre-and postcontrast CT

  6. Clinical values of CT and dynamic CT in brain infarction

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Soo Il; Jang, Do; Seo, Eun Joo; Sohn, Myung Hee; Choi, Ki Chul [Chonbuk National University College of Medicine, Jeonju (Korea, Republic of)

    1985-04-15

    With the advent of faster scan time and new computer program, a scanning technique called 'dynamic computed tomography' has become possible. Dynamic computed tomography consisted of performing multiple rapid sequence scans after injection of contrast material. The authors have evaluated the clinical usefulness of computed tomography and dynamic computed tomography of 93 patients with brain infarction and/or ischemia during the period of 17 months from April 1983 to August 1984 in Department of Radiology, Chonbuk National University Hospital. The results were as follows; 1. The age distribution ranged from 18 years to 78 years. Among them the most common age group was between 50 years and 59 years (40.9%). 2. The sites of brain infarction were cerebral lobes (63 cases,68), basal ganglia (15 cases, 16.1%) and multiple sites (6 cases, 6.4%). The common affected site was middle cerebral artery territories. 3. The contrast enhancement of acute infarction was noted in 14 cases (17.5%) which occurred commonly between 3 days and 2 weeks from ictus. 4. The patterns of time-density curve in brain infarction and/or ischemia were as follow: a. Depression of slow wash-in phase was 20 cases (59%). b. Lower peak concentration was 17 cases (50%). c. Lower and delayed peak concentration was 7 cases (21%). d. No definite peak concentration was 6 cases (18%). First three patterns of time-density curve were thought as relatively characteristic curve of brain infarction and/or ischemia. 5. Two cases that showed negative findings on precontrast CT scan appeared to be positive findings as hypodensity on postcontrast CT scan and were confirmed as brain infarction by dynamic CT. 6. The diagnostic entity of dynamic CT scan were as follows; a. large artery thrombotic infarction were 23 cases (58%). b. lacnar infarction were 6 cases (15%). c. ischemia were 5 cases (13%). d. normal were 5 cases (13%). In six cases of lacunar infarction which was double hypodensity on pre

  7. CT findings at lupus mesenteric vasculitis

    International Nuclear Information System (INIS)

    Ko, S.F.; Lee, T.Y.; Cheng, T.T.; Ng, S.H.; Lai, H.M.; Cheng, Y.F.; Tsai, C.C.

    1997-01-01

    Purpose: To describe the spectrum of early CT findings of lupus mesenteric vasculitis (LMV) and to assess the utility of CT in the management of this uncommon entity. Methods: Abdominal CT was performed within 1-4 days (average 2.2 days) of the onset of severe abdominal pain and tenderness in 15 women with systemic lupus erythematosus. Prompt high-dose i.v. corticosteroid in 11 patients after the CT diagnosis of LMV was made. CT was performed after abdominal symptoms subsided. Results: Eleven cases revealed CT features suggestive of LMV including conspicuous prominence of mesentric vessels with palisade pattern or comb-like appearance (CT comb sign) supplying focal or diffuse dilated bowel loops (n=11), ascites with slightly increased peritoneal enhancement (n=11), small bowel wall thickening (n=10) with double halo or target sign (n=8). Follow-up CT before high-dose steroid therapy revealed complete or marked resolution of the abnormal CT findings. Conclusion: CT is helpful for confirming the diagnosis of LMV, especially the comb sign which may be an early sign. Bowel ischemia due to LMV is less ominous than previously expected, and the abnormal CT findings were reversible when early diagnosis and prompt i.v. steroid therapy could be achieved. (orig.)

  8. CT findings at lupus mesenteric vasculitis

    Energy Technology Data Exchange (ETDEWEB)

    Ko, S.F. [Chang Gung Medical College and Memorial Hospital, Dept. of Radiology, Kaohsiung Hsien (Taiwan); Lee, T.Y. [Chang Gung Medical College and Memorial Hospital, Dept. of Radiology, Kaohsiung Hsien (Taiwan); Cheng, T.T. [Chang Gung Medical College and Memorial Hospital, Dept. of Rheumatology, Kaohsiung Hsien (Taiwan); Ng, S.H. [Chang Gung Medical College and Memorial Hospital, Dept. of Radiology, Kaohsiung Hsien (Taiwan); Lai, H.M. [Chang Gung Medical College and Memorial Hospital, Dept. of Rheumatology, Kaohsiung Hsien (Taiwan); Cheng, Y.F. [Chang Gung Medical College and Memorial Hospital, Dept. of Radiology, Kaohsiung Hsien (Taiwan); Tsai, C.C. [Chang Gung Medical College and Memorial Hospital, Dept. of Radiology, Kaohsiung Hsien (Taiwan)

    1997-01-01

    Purpose: To describe the spectrum of early CT findings of lupus mesenteric vasculitis (LMV) and to assess the utility of CT in the management of this uncommon entity. Methods: Abdominal CT was performed within 1-4 days (average 2.2 days) of the onset of severe abdominal pain and tenderness in 15 women with systemic lupus erythematosus. Prompt high-dose i.v. corticosteroid in 11 patients after the CT diagnosis of LMV was made. CT was performed after abdominal symptoms subsided. Results: Eleven cases revealed CT features suggestive of LMV including conspicuous prominence of mesentric vessels with palisade pattern or comb-like appearance (CT comb sign) supplying focal or diffuse dilated bowel loops (n=11), ascites with slightly increased peritoneal enhancement (n=11), small bowel wall thickening (n=10) with double halo or target sign (n=8). Follow-up CT before high-dose steroid therapy revealed complete or marked resolution of the abnormal CT findings. Conclusion: CT is helpful for confirming the diagnosis of LMV, especially the comb sign which may be an early sign. Bowel ischemia due to LMV is less ominous than previously expected, and the abnormal CT findings were reversible when early diagnosis and prompt i.v. steroid therapy could be achieved. (orig.).

  9. The impact of the PET/CT in comparison with the same day contrast enhanced CT in breast cancer management

    International Nuclear Information System (INIS)

    Piperkova, E.; Raphael, B.; Altinyay, M.; Castellon, I.; Libes, R.; Abdel-Dayem, H.

    2006-01-01

    Full text: The aim of this study is to evaluate the impact of 18F-fluorodeoxyglucose FDG positron emission tomography with fused computerized tomography (PET/CT) in comparison with the same day contrast enhanced CT (CE-CT) in the breast cancer (BC) management. 68 studies in 48 BC patients, 8 for initial and 60 for restaging disease, after surgery, radiation/chemotherapy, for radiation therapy planning or evaluating treatment response were included. All patients underwent whole body PET/CT for diagnostic purposes followed by CE-CT diagnostic scans of selected body regions. PET/CT was performed approximately 90 minutes following 10-15 mCi of 18F-FDG on a GE Discovery PET/CT system. CT part acquired with low dose X-ray for localization and attenuation correction. The CE-CT was performed according to departmental protocol. Out of a total of 235 lesions in 68 PET/CT and CE-CT studies, 189 were concordant between PET/CT and CE-CT. However, there were 46 discordant lesions, which were verified by either follow-up or biopsy. PET/CT correctly identified 25 (True Positive-TP). CE-CT identified 2 TP lesions missed by PET/CT (False negative): one liver metastasis with necrosis, which is a known non-avid FDG, the other was a missed abdominal metastatic node, which did not change staging or treatment. PET/CT incorrectly identified 2 lesions (False Positive) while CE-CT incorrectly identified 17 FP. For evaluating treatment response in 40 follow up studies PET/CT reported complete response in 15, partial response in 11, stable disease in 2, progression in 5, and free of disease following surgery - in 7. The CE-CT described progression of the disease in 1 PET/CT true negative study and no progression in 2 TP PET/CT studies. In this study, PET/CT played more important role than CECT scans alone and provided an impact on the management of BC patients

  10. CT, MRI, and FDG PET/CT findings of sinonasal sarcoma: Differentiation from squamous cell carcinoma

    International Nuclear Information System (INIS)

    Kim, Jin Ho; Yoon, Dae Young; Baek, Sora; Park, Min Woo; Kwon, Kee Hwan; Rho, Young Soo

    2016-01-01

    To evaluate computed tomography (CT), magnetic resonance imaging (MRI), and 18F-fluorodeoxyglucose (FDG) positron emission tomography/CT (PET/CT) findings for the differentiation of sinonasal sarcoma from squamous cell carcinoma (SCC). We retrospectively reviewed CT, MRI, and FDG PET/CT results in 20 patients with pathologically proven sinonasal sarcoma (n = 7) and SCC (n = 13). Imaging characteristics of tumors, such as the shape, size, margin, MRI signal intensity, pattern of enhancement, local tumor invasion, and maximum standardized uptake value (SUVmax) were analyzed and compared between sarcoma and SCC. The SUVmax of sarcomas (7.4 ± 2.1) was significantly lower than the SUVmax of the SCCs (14.3 ± 4.5) (p = 0.0013). However, no significant difference in the shape, size, margin, MRI signal intensity, pattern of enhancement, and local tumor invasion was observed between sarcoma and SCC. Although CT and MR imaging features are nonspecific, FDG PET/CT is useful in distinguishing between sinonasal sarcoma and SCC based on the SUVmax value

  11. CT, MRI, and FDG PET/CT findings of sinonasal sarcoma: Differentiation from squamous cell carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Ho; Yoon, Dae Young; Baek, Sora; Park, Min Woo; Kwon, Kee Hwan; Rho, Young Soo [Kangdong Sacred Heart Hospital, Hallym University College of Medicine, Seoul (Korea, Republic of)

    2016-07-15

    To evaluate computed tomography (CT), magnetic resonance imaging (MRI), and 18F-fluorodeoxyglucose (FDG) positron emission tomography/CT (PET/CT) findings for the differentiation of sinonasal sarcoma from squamous cell carcinoma (SCC). We retrospectively reviewed CT, MRI, and FDG PET/CT results in 20 patients with pathologically proven sinonasal sarcoma (n = 7) and SCC (n = 13). Imaging characteristics of tumors, such as the shape, size, margin, MRI signal intensity, pattern of enhancement, local tumor invasion, and maximum standardized uptake value (SUVmax) were analyzed and compared between sarcoma and SCC. The SUVmax of sarcomas (7.4 ± 2.1) was significantly lower than the SUVmax of the SCCs (14.3 ± 4.5) (p = 0.0013). However, no significant difference in the shape, size, margin, MRI signal intensity, pattern of enhancement, and local tumor invasion was observed between sarcoma and SCC. Although CT and MR imaging features are nonspecific, FDG PET/CT is useful in distinguishing between sinonasal sarcoma and SCC based on the SUVmax value.

  12. CT of hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, H; Tanaka, T; Sai, H; Kawamoto, S; Morimoto, K [Osaka Univ. (Japan). Faculty of Medicine

    1982-06-01

    CT was investigated in 125 cases of hepatocelluar carcinoma and 47 cases of metastatic hepatic neoplasm. The entire contour of each tumor was traced and the average CT value in the tumor was estimated. As a result, the CT value for hepatocellular carcinoma tended to be higher on plain CT and also after contrast enhancement. The CT findings seen frequently were as follows: capsule in 76 cases (60.8%) and septum in 67 cases (53.6%); tumor thrombus in portal vein in 39 cases (31.2%) and that in inferior vena cava in 3 cases (2.4%); localized enlargement of hepatic bile duct in 24 cases (19.2%). These findings were rarely seen in the cases of metastatic hepatic neoplasm. As a relatively outstanding feature of hepatic metastases, a double contour, like concentric circles or contour lines, with a relatively large inner circle or contour line, was found in 21 cases (44.7%). By paying attention to the change of CT value on contrast enhancement and the characteristic image of each case, hepatocellular carcinoma could be differentiated from metastatic hepatic neoplasm with high probability.

  13. Head trauma and CT

    International Nuclear Information System (INIS)

    Samejima, Kanji; Yoshii, Nobuo; Tobari, Chitoshi

    1979-01-01

    It has been said that chronic subdural hematoma cannot be diagnosed by CT. In our cases, CT was used, and the results were described. According to the density of the picture, CT findings of chronic subdural hematoma could be classified into 3 types, those of higher density than that of the cerebral paranchyma, those of isodensity, and those of lower density than that of the cerebral parenchyma. The difference among them appeared to be due to variation in the fluid in hematoma, especially that in hemoglobin concentration. Chronic subdural hematoma was found in 27 of 388 cases of head trauma in which CT was undertaken in our department of surgery for last 2 years. It is difficult to differenciate this disease from subdural edema or subarachnoideal retention of the cerebrospinal fluid. In many cases, use of contrast medium added no change to the CT picture. Cerebral angiography is necessary for definite diagnosis of the disease. Chronic subdural hematoma gives more varieties of findings than other intracranial hematomas. However, if the film is very carefully read, CT is still useful for diagnosing this disease in spite of initially remarked difficulties. (Ueda, J.)

  14. Imaging of acute mesenteric ischemia using multidetector CT and CT angiography in a porcine model.

    Science.gov (United States)

    Rosow, David E; Sahani, Dushyant; Strobel, Oliver; Kalva, Sanjeeva; Mino-Kenudson, Mari; Holalkere, Nagaraj S; Alsfasser, Guido; Saini, Sanjay; Lee, Susanna I; Mueller, Peter R; Fernández-del Castillo, Carlos; Warshaw, Andrew L; Thayer, Sarah P

    2005-12-01

    Acute mesenteric ischemia, a frequently lethal disease, requires prompt diagnosis and intervention for favorable clinical outcomes. This goal remains elusive due, in part, to lack of a noninvasive and accurate imaging study. Traditional angiography is the diagnostic gold standard but is invasive and costly. Computed tomography (CT) is readily available and noninvasive but has shown variable success in diagnosing this disease. The faster scanning time of multidetector row CT (M.D.CT) greatly facilitates the use of CT angiography (CTA) in the clinical setting. We sought to determine whether M.D.CT-CTA could accurately demonstrate vascular anatomy and capture the earliest stages of mesenteric ischemia in a porcine model. Pigs underwent embolization of branches of the superior mesenteric artery, then imaging by M.D.CT-CTA with three-dimensional reconstruction protocols. After scanning, diseased bowel segments were surgically resected and pathologically examined. Multidetector row CT and CT angiography reliably defined normal and occluded mesenteric vessels in the pig. It detected early changes of ischemia including poor arterial enhancement and venous dilatation, which were seen in all ischemic animals. The radiographic findings--compared with pathologic diagnoses-- predicted ischemia, with a positive predictive value of 92%. These results indicate that M.D.CT-CTA holds great promise for the early detection necessary for successful treatment of acute mesenteric ischemia.

  15. CT-guided stereotactic neurosurgery

    International Nuclear Information System (INIS)

    Takizawa, Takaaki; Sato, Shoju; Matsumoto, Akira; Sano, Akira; Takahashi, Kazunori; Murakami, Yuji; Ohta, Kosuke

    1985-01-01

    Brown-Roberts-Wells stereotactic instruments were used for CT guided stereotactic surgery in 54 cases (65 operations). Stereotactic biopsy was done in 9 cases and successive regional chemotherapy was done in 3 cases. Stereotactic drainage was done in 2 cases of bacterial abcess, 3 cases of cystic neoplasm and 33 cases (43 operations) of intracerebral hematoma. CT guided stereotactic procedure was valuable for the correct cannulation to the center of the cavity. We tried to utilize CT image for the selection of targets for stereotactic functional neurosurgical procedures in 6 cases. In the cases of thalamotomy, the information derived from CT made the operation safer than that by contrast ventriculography alone. In all cases of electrode implantation for deep brain stimulation, accurate and precise electrode placement was achieved from CT images alone. This rapid and easy surgical technique was useful also for poor risk patients. (author)

  16. WWW expert system on producer gas cleaning

    Energy Technology Data Exchange (ETDEWEB)

    Schouten, E.J.; Lammers, G.; Beenackers, A.A.C.M. [University of Groningen (Netherlands)

    1999-07-01

    The University of Groningen (RUG) has developed an expert system on cleaning of biomass producer gas. This work was carried out in close co-operation with the Biomass Technology Group B.V. (BTG) in Enschede, The Netherlands within the framework of the EC supported JOR3-CT95-0084 project. The expert system was developed as a tool for the designer-engineer of downstream gas cleaning equipment and consists of an information package and a flowsheet package. The packages are integrated in a client/server system. The flowsheeting package of the expert system has been designed for the evaluation of different gas cleaning methods. The system contains a number of possible gas cleaning devices such as: cyclone, fabric filter, ceramic filter, venturi scrubber and catalytic cracker. The user can select up to five cleaning steps in an arbitrary order for his specific gas cleaning problem. After specification of the required design parameters, the system calculates the main design characteristics of the cleaning device. The information package is a collection of HTML{sup TM} files. It contains a large amount of information, tips, experience data, literature references and hyperlinks to other interesting Internet sites. This information is arranged per cleaning device. (orig.)

  17. Thyroid lymphography-computed tomography (TLG-CT)

    International Nuclear Information System (INIS)

    Matsuyama, Koukichi

    1992-01-01

    There are several useful diagnostic examinations for thyroid disease. The diagnostic value of CT in thyroid disease is still controvertial, although CT has become a routine clinical examination, since the plain CT does not always identify tumors accurately. In this paper, we introduce for the first time thyroid lymphography-computed tomography (TLG-CT) which may improve the diagnostic value of CT. The technique combines CT with thyroid lymphography. We performed TLG-CT in 92 patients with various thyroid diseases and 20 normal controls and classified the radiological features into the following 6 types: entire (normal thyroid); moth-eaten (Hashimoto's thyroiditis); defect (follicular adenoma and adenomatous goiter); lobate (papillary carcinoma); localized (various thyroid diseases); and extrathyroid defect (parathyroid tumor). In addition, we examined the relationship between TLG-CT type and the macroscopic appearance of the cut surface of the thyroid and lymph node metastasis in 20 patients with papillary carcinoma. The results suggest that papillary TLG-CT type carcinomas have a high incidence of lymph node metastasis. Our preliminary results suggest that TLG-CT is a potentially valuable diagnostic tool in the detection of thyroid disease and the assessment of the pathologic diagnosis as well as lymph node metastasis. (author)

  18. [Accurate 3D free-form registration between fan-beam CT and cone-beam CT].

    Science.gov (United States)

    Liang, Yueqiang; Xu, Hongbing; Li, Baosheng; Li, Hongsheng; Yang, Fujun

    2012-06-01

    Because the X-ray scatters, the CT numbers in cone-beam CT cannot exactly correspond to the electron densities. This, therefore, results in registration error when the intensity-based registration algorithm is used to register planning fan-beam CT and cone-beam CT. In order to reduce the registration error, we have developed an accurate gradient-based registration algorithm. The gradient-based deformable registration problem is described as a minimization of energy functional. Through the calculus of variations and Gauss-Seidel finite difference method, we derived the iterative formula of the deformable registration. The algorithm was implemented by GPU through OpenCL framework, with which the registration time was greatly reduced. Our experimental results showed that the proposed gradient-based registration algorithm could register more accurately the clinical cone-beam CT and fan-beam CT images compared with the intensity-based algorithm. The GPU-accelerated algorithm meets the real-time requirement in the online adaptive radiotherapy.

  19. CT scanning in pediatric head trauma: correlation of clinical features with CT scan diagnosis

    International Nuclear Information System (INIS)

    Arkoncel, Mary Ann P.; Posadas, Ma. Belen A.

    1997-01-01

    A retrospective review was conducted on 205 cases of pediatric head trauma for which cranial computed tomography scans were done at the Makati Medical Center, to determine which clinical features might positively predict an abnormality on CT scan. The clinical findings of loss of consciousness, GCS < 12, vomiting headache, seizures, and focal abnormalities on Neurologic Examination were significantly associated with abnormal findings on CT scan. However, a significant discrepancy does exist as to how accurately clinical findings do in fact predict normal and abnormal CT scan findings. Such a discrepancy allows us to conclude that a more liberal use of CT Scanning in cases of pediatric head trauma must be stressed to insure proper diagnosis. This study shows that when a patient presents with the aforementioned positive signs and symptoms, or with a focal neurologic deficit, or in combination, a 60-100 % positive prediction of abnormal CT Scan can be made. However, prediction of normal CT Scan is only 0-40%. (Author)

  20. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... or nurse at the time of the CT examination. If your child has a known contrast material ... be given to your child for the CT examination. top of page What does the CT equipment ...

  1. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is ... a CT scan. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  2. Scatter Correction with Combined Single-Scatter Simulation and Monte Carlo Simulation Scaling Improved the Visual Artifacts and Quantification in 3-Dimensional Brain PET/CT Imaging with 15O-Gas Inhalation.

    Science.gov (United States)

    Magota, Keiichi; Shiga, Tohru; Asano, Yukari; Shinyama, Daiki; Ye, Jinghan; Perkins, Amy E; Maniawski, Piotr J; Toyonaga, Takuya; Kobayashi, Kentaro; Hirata, Kenji; Katoh, Chietsugu; Hattori, Naoya; Tamaki, Nagara

    2017-12-01

    In 3-dimensional PET/CT imaging of the brain with 15 O-gas inhalation, high radioactivity in the face mask creates cold artifacts and affects the quantitative accuracy when scatter is corrected by conventional methods (e.g., single-scatter simulation [SSS] with tail-fitting scaling [TFS-SSS]). Here we examined the validity of a newly developed scatter-correction method that combines SSS with a scaling factor calculated by Monte Carlo simulation (MCS-SSS). Methods: We performed phantom experiments and patient studies. In the phantom experiments, a plastic bottle simulating a face mask was attached to a cylindric phantom simulating the brain. The cylindric phantom was filled with 18 F-FDG solution (3.8-7.0 kBq/mL). The bottle was filled with nonradioactive air or various levels of 18 F-FDG (0-170 kBq/mL). Images were corrected either by TFS-SSS or MCS-SSS using the CT data of the bottle filled with nonradioactive air. We compared the image activity concentration in the cylindric phantom with the true activity concentration. We also performed 15 O-gas brain PET based on the steady-state method on patients with cerebrovascular disease to obtain quantitative images of cerebral blood flow and oxygen metabolism. Results: In the phantom experiments, a cold artifact was observed immediately next to the bottle on TFS-SSS images, where the image activity concentrations in the cylindric phantom were underestimated by 18%, 36%, and 70% at the bottle radioactivity levels of 2.4, 5.1, and 9.7 kBq/mL, respectively. At higher bottle radioactivity, the image activity concentrations in the cylindric phantom were greater than 98% underestimated. For the MCS-SSS, in contrast, the error was within 5% at each bottle radioactivity level, although the image generated slight high-activity artifacts around the bottle when the bottle contained significantly high radioactivity. In the patient imaging with 15 O 2 and C 15 O 2 inhalation, cold artifacts were observed on TFS-SSS images, whereas

  3. CT diagnosis of acute spinal injury

    International Nuclear Information System (INIS)

    Ohhama, Mitsuru; Niimiya, Hikosuke; Kimura, Ko; Yamazaki, Gyoji; Nasu, Yoshiro; Shioya, Akihide

    1982-01-01

    CT pictures of 22 acute spinal injuries with damage of the spinal cord were evaluated. In the cases of spinal cord damage with bone injury, changes in the vertebral canal were fully observed by CT. In some of spinal cord damages without bone injury, narrowing of the vertebral canal was demonstrated by CT combined with CT myelography and reconstruction. Evaluation of CT number showed a high density area in damaged spinal cord in some cases. CT was thus considered to be useful as an adjunct diagnostic aid. (Ueda, J.)

  4. Positron emission tomography/computed tomography (PET/CT) and CT for N staging of non-small cell lung cancer.

    Science.gov (United States)

    Vegar Zubović, Sandra; Kristić, Spomenka; Hadžihasanović, Besima

    2017-08-01

    Aim The aim of this study is to investigate the possibilities of non-invasive diagnostic imaging methods, positron emission tomography/computed tomography (PET/CT) and CT, in clinical N staging of non-small cell lung cancer (NSCLC). Methods Retrospective clinical study included 50 patients with diagnosed NSCLC who have undergone PET/CT for the purpose of disease staging. The International association for the study of lung cancer (IASLC) nodal mapping system was used for analysis of nodal disease. Data regarding CT N-staging and PET/CT Nstaging were recorded. Two methods were compared using χ2 test and Spearman rank correlation coefficient. Results Statistical analysis showed that although there were some differences in determining the N stage between CT and PET/CT, these methods were in significant correlation. CT and PET/CT findings established the same N stage in 74% of the patients. In five patients based on PET/CT findings the staging was changed from operable to inoperable, while in four patients staging was changed from inoperable to operable. Conclusion PET/CT and CT are noninvasive methods that can be reliably used for N staging of NSCLC. Copyright© by the Medical Assotiation of Zenica-Doboj Canton.

  5. Volume-artifact reduction modality by helical CT of the anterior, middle and posterior carnial fossae. Comparison with conventional CT; Volumen-Artefakt-Reduktionstechnik mittels Spiral-CT in der vorderen, mittleren und hinteren Schaedelgrube. Vergleich mit der konventionellen kranialen CT

    Energy Technology Data Exchange (ETDEWEB)

    Dorenbeck, U.; Finkenzeller, T.; Hill, K.; Feuerbach, S.; Link, J. [Regensburg Univ. (Germany). Inst. fuer Roentgendiagnostik

    2000-04-01

    Purpose: The object of this study was to determine the extent to which a new volume-artifact reduction (VAR) modality using helical CT was able to reduce artifacts in the anterior, middle and posterior fossae in comparison with conventional CT (sequential mode). Methods: In a prospective, randomized trial, 50 patients underwent helical CT (VAR) and 50 underwent sequential CT. The results were evaluated by three radiologists; influences on image quality where scaled between 1 (no artifact) and 4 (not assessable). Eight regions of the anterior, middle and posterior fossae were evaluated. Results: On average, artifacts were scaled at 2.5 in helical CT (VAR) and 3.1 in conventional CT. Significant differences were seen at the eyeball, anterior to the petrosol bone, at the internal occipital crest, and at the level of the transverse sinus (p<0.005). Conclusions: Helical CT with the VAR modality is superior to conventional, sequential CT in the area of the anterior, middle and posterior fossae. (orig.) [German] Ziel: Das Ziel dieser Studie war herauszufinden, inwieweit ein neuer Volumen-Artefakt-Reduktionsmodus (VAR) im Spiral-CT in der vorderen, mittleren und hinteren Schaedelgrube gegenueber der Einzelschicht-CT zu einer Artefaktverringerung beitragen kann. Methoden: In einer prospektiven randomisierten Studie wurden 50 Untersuchungen mit Spiral-CT und 50 mit Einzelschicht-CT bezueglich Artefakten verglichen. Die Auswertung erfolgte durch drei Radiologen, die Bildqualitaet wurde in einer Skala zwischen 1 (kein Artefakt) und 4 (Beurteilung der Region wegen Artefakten nicht moeglich) angegeben. Acht anatomische Regionen in der vorderen, mittleren und hinteren Schaedelgrube wurden auf Beeintraechtigung durch Artefakte untersucht. Ergebnisse: Im Durchschnitt betrug die Bewertung fuer die Artefaktbeeintraechtigung beim Spiral-CT (VAR) 2,5 gegenueber 3,1 bei der Einzelschicht-CT. Der VAR-Modus ermoeglichte in der mittleren und hinteren Schaedelgrube sowie im Balbus oculi

  6. Flat-detector computed tomography (FD-CT)

    International Nuclear Information System (INIS)

    Kalender, Willi A.; Kyriakou, Yiannis

    2007-01-01

    Flat-panel detectors or, synonymously, flat detectors (FDs) have been developed for use in radiography and fluoroscopy with the defined goal to replace standard X-ray film, film-screen combinations and image intensifiers by an advanced sensor system. FD technology in comparison to X-ray film and image intensifiers offers higher dynamic range, dose reduction, fast digital readout and the possibility for dynamic acquisitions of image series, yet keeping to a compact design. It appeared logical to employ FD designs also for computed tomography (CT) imaging. Respective efforts date back a few years only, but FD-CT has meanwhile become widely accepted for interventional and intra-operative imaging using C-arm systems. FD-CT provides a very efficient way of combining two-dimensional (2D) radiographic or fluoroscopic and 3D CT imaging. In addition, FD technology made its way into a number of dedicated CT scanner developments, such as scanners for the maxillo-facial region or for micro-CT applications. This review focuses on technical and performance issues of FD technology and its full range of applications for CT imaging. A comparison with standard clinical CT is of primary interest. It reveals that FD-CT provides higher spatial resolution, but encompasses a number of disadvantages, such as lower dose efficiency, smaller field of view and lower temporal resolution. FD-CT is not aimed at challenging standard clinical CT as regards to the typical diagnostic examinations; but it has already proven unique for a number of dedicated CT applications, offering distinct practical advantages, above all the availability of immediate CT imaging in the interventional suite or the operating room. (orig.)

  7. Imaging and PET - PET/CT imaging

    International Nuclear Information System (INIS)

    Von Schulthess, G.K.; Hany, Th.F.

    2008-01-01

    PET/CT has grown because the lack of anatomic landmarks in PET makes 'hardware-fusion' to anatomic cross-sectional data extremely useful. Addition of CT to PET improves specificity, but also sensitivity, and adding PET to CT adds sensitivity and specificity in tumor imaging. The synergistic advantage of adding CT is that the attenuation correction needed for PET data can also be derived from the CT data. This makes PET-CT 25-30% faster than PET alone, leading to higher patient throughput and a more comfortable examination for patients typically lasting 20 minutes or less. FDG-PET-CT appears to provide relevant information in the staging and therapy monitoring of many tumors, such as lung carcinoma, colorectal cancer, lymphoma, gynaecological cancers, melanoma and many others, with the notable exception of prostatic cancer. for this cancer, choline derivatives may possibly become useful radiopharmaceuticals. The published literature on the applications of FDG-PET-CT in oncology is still limited but several designed studies have demonstrated the benefits of PET-CT. (authors)

  8. CT of tracheal agenesis

    International Nuclear Information System (INIS)

    Strouse, Peter J.; Hernandez, Ramiro J.; Newman, Beverley

    2006-01-01

    Tracheal agenesis is a rare and usually lethal anomaly. In the past, opaque contrast medium was injected via the esophagus to demonstrate the anatomy. To demonstrate the utility of helical and multidetector CT in delineating the aberrant anatomy in newborns with tracheal agenesis. Four newborns with tracheal agenesis were identified from three institutions. Imaging studies and medical records were reviewed. Each child was imaged with chest radiography. One child was imaged on a single-detector helical CT scanner and the other three on multidetector scanners. Helical and multidetector CT with 2D and 3D reconstructions clearly delineated the aberrant tracheobronchial and esophageal anatomy in each infant. Minimum intensity projection reformatted CT images were particularly helpful. One infant each had type I and type II tracheal agenesis. Two infants had type III tracheal agenesis. All four infants died. CT is a useful tool for delineating the aberrant anatomy of newborns with tracheal agenesis and thus helps in making rational clinical decisions. (orig.)

  9. Head trauma and CT

    International Nuclear Information System (INIS)

    Samejima, Kanji; Yoshii, Nobuo; Tobari, Chitoshi

    1979-01-01

    In our cases of acute and subacute subdural hematoma, the use of CT was evaluated. In our department of surgery, acute subdural hematoma was found in 46 of 388 patients of head trauma who underwent CT. Acute subdural hematoma, like epidural hematoma was usually visualized as a high-density area along the cranial inner table, and this was easily differenciated from epidural hematoma because of difference in shape from the other. The picture of acute subdural hematoma was occasionally confused with that of intracerebral hematoma or cerebral contusion. Single use of CT does not differenciate subacute subdural hematoma from chronic subdural hematoma. However, CT usually visualized acute hematoma as a high-density area, showing the extent of hematoma. Comparison of the thickness of hematoma with the axis deviation of the median part such as the 3rd cerebral ventricle suggested severity of cerebral edema. CT also revealed bilateral or multiple lesions of cerebral contusion or intracerebral hematoma. (Ueda, J.)

  10. CT of laryngeal trauma

    International Nuclear Information System (INIS)

    Jeffrey, R.B.

    1986-01-01

    Computed tomography has made a significant contribution to the radiologic assessment of the injured larynx. CT is an accurate, noninvasive modality that can rapidly diagnose both soft tissue and cartilaginous injuries. CT of the larynx involves a minimal degree of patient manipulation and discomfort and can be performed in conjunction with CT evaluation of intracranial or facial injuries. Conventional radiologic studies (anteroposterior and lateral soft tissue films of the neck, tomograms, or xerograms) are capable of demonstrating some cartilaginous fractures but are of limited value in defining the extent of soft tissue injury. In the acute trauma setting, laryngography is often technically difficult to perform because of patient discomfort and inability to cooperate. Although the overall experience is somewhat limited, CT appears to overcome many of the limitations of these conventional radiologic methods. The following is a discussion of the role of CT scanning in evaluating injuries to the larynx and cervical soft tissues

  11. Congenital bronchopulmonary malformation: CT histopathological correlation.

    Science.gov (United States)

    Kyncl, Martin; Koci, Martin; Ptackova, Lea; Hornofova, Ludmila; Ondrej, Fabian; Snajdauf, Jiri; Pychova, Marcela

    2016-12-01

    This study evaluated the accuracy of postnatal computed tomography (CT) imaging in the identification of congenital bronchopulmonary malformation (BPM) in comparison with histopathological analysis. CT scans of prenatally diagnosed BPMs from 24 patients with available histology were analysed retrospectively. The CT images were reviewed blinded to histological findings by two radiologists. Specific diagnosis was assigned based on predetermined criteria. The accuracy of CT was evaluated. The agreement rate in CT diagnosis between two radiologists was 100%. In 75% the lesions were located in the lower lobes. An overlap of 71% in CT and histopathological diagnoses was reached. The least matching diagnosis was type 2 CPAM. Contrast enhanced chest CT is very accurate in characterizing the BPM spectrum and provides important information on lesion type and structure.

  12. SU-F-J-108: TMR Correction Factor Based Online Adaptive Radiotherapy for Stereotactic Radiosurgery (SRS) of L-Spine Tumors Using Cone Beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Ghaffar, I; Balik, S; Zhuang, T; Chao, S; Xia, P [The Cleveland Clinic Foundation, Cleveland, OH (United States)

    2016-06-15

    Purpose: To investigate the feasibility of using TMR ratio correction factors for a fast online adaptive plan to compensate for anatomical changes in stereotactic radiosurgery (SRS) of L-spine tumors. Methods: Three coplanar treatment plans were made for 11 patients: Uniform (9 IMRT beams equally distributed around the patient); Posterior (IMRT with 9 posterior beams every 20 degree) and VMAT (2 360° arcs). For each patient, the external body and bowel gas were contoured on the planning CT and pre-treatment CBCT. After registering CBCT and the planning CT by aligning to the tumor, the CBCT contours were transferred to the planning CT. To estimate the actual delivered dose while considering patient’s anatomy of the treatment day, a hybrid CT was created by overriding densities in planning CT using the differences between CT and CBCT external and bowel gas contours. Correction factors (CF) were calculated using the effective depth information obtained from the planning system using the hybrid CT: CF = TMR (delivery)/TMR (planning). The adaptive plan was generated by multiplying the planned Monitor Units with the CFs. Results: The mean absolute difference (MAD) in V16Gy of the target between planned and estimated delivery with and without TMR correction was 0.8 ± 0.7% vs. 2.4 ± 1.3% for Uniform and 1.0 ± 0.9% vs. 2.6 ± 1.3% for VMAT plans(p<0.05), respectively. For V12Gy of cauda-equina with and without TMR correction, MAD was 0.24 ± 0.19% vs. 1.2 ± 1.02% for Uniform and 0.23 ± 0.20% vs. 0.78 ± 0.79% for VMAT plans(p<0.05), respectively. The differences between adaptive and original plans were not significant for posterior plans. Conclusion: The online adaptive strategy using TMR ratios and pre-treatment CBCT information was feasible strategy to compensate for anatomical changes for the patients treated for L-spine tumors, particularly for equally spaced IMRT and VMAT plans.

  13. CT findings of inoperable lung carcinoma

    International Nuclear Information System (INIS)

    Gay, S.B.; Black, W.C.

    1987-01-01

    CT is useful in the evaluation of patients with newly diagnosed or highly suspected lung cancer. The principal role of CT is to screen those patients with metastatic disease beyond the hili from an attempt at curative thoracotomy. While CT is regarded as very sensitive, it is not considered highly specific, and thus a surgical procedure is usually recommended for definitive diagnosis of most ''positive'' CT findings. However, the authors demonstrate a few characteristic CT findings that are highly predictive of unresectable metastatic disease. These CT findings include massive mediastinal lymphadenopathy, diffuse mediastinal infiltration, pericardial involvement, vascular encasement, and advanced chest wall invasion

  14. Thyroid lymphography-computed tomography (TLG-CT)

    Energy Technology Data Exchange (ETDEWEB)

    Matsuyama, Koukichi (Kansai Medical Univ., Moriguchi, Osaka (Japan))

    1992-10-01

    There are several useful diagnostic examinations for thyroid disease. The diagnostic value of CT in thyroid disease is still controvertial, although CT has become a routine clinical examination, since the plain CT does not always identify tumors accurately. In this paper, we introduce for the first time thyroid lymphography-computed tomography (TLG-CT) which may improve the diagnostic value of CT. The technique combines CT with thyroid lymphography. We performed TLG-CT in 92 patients with various thyroid diseases and 20 normal controls and classified the radiological features into the following 6 types: entire (normal thyroid); moth-eaten (Hashimoto's thyroiditis); defect (follicular adenoma and adenomatous goiter); lobate (papillary carcinoma); localized (various thyroid diseases); and extrathyroid defect (parathyroid tumor). In addition, we examined the relationship between TLG-CT type and the macroscopic appearance of the cut surface of the thyroid and lymph node metastasis in 20 patients with papillary carcinoma. The results suggest that papillary TLG-CT type carcinomas have a high incidence of lymph node metastasis. Our preliminary results suggest that TLG-CT is a potentially valuable diagnostic tool in the detection of thyroid disease and the assessment of the pathologic diagnosis as well as lymph node metastasis. (author).

  15. CT diagnosis of hepatoma

    Energy Technology Data Exchange (ETDEWEB)

    Itai, Yuji [Tokyo Univ. (Japan). Faculty of Medicine

    1982-04-01

    In hepatocellular carcinoma, present status of CT diagnosis was discussed. Hepatocellular carcinoma is sometimes imaged in same concentration as that of surrounding tissues, and the detection rate ranged from 79 to 94%. The rate of differential diagnosis between primary and metastatic carcinoma was only 83% (includes 22% of false diagnosis) using contrast enhancement. The rates of detection of hepatocellular carcinoma and metastatic one were also only 87% and 75%, respectively, even by the combined use of arterial infusion CT and dynamic CT. However, the CT images is reproducible, and is supplemented by the information of US. Thus, the combination of these methods is useful in diagnosing the presence, extension, and nature of liver carcinoma.

  16. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... What is Children's CT? What are some common uses of the procedure? How should we prepare for the CT scan? What does the CT equipment look like? How does the procedure work? How is the procedure performed? What will my ...

  17. The role of CT in diagnosing small hepatic tumors; Usefulness of table incremental dynamic CT (ICT)

    Energy Technology Data Exchange (ETDEWEB)

    Usuki, Noriaki; Daikokuya, Hideo; Fukuda, Haruyuki; Saiwai, Shigeo; Nakajima, Hideyuki; Miyamoto, Takeshi; Kudo, Masatoshi (Kobe General Hospital, Hyogo (Japan))

    1992-11-01

    Twenty-seven cases of small hepatic tumors were examined by MRI and CT (ICT). MRI was more sensitive than plain and contrast CT. But ICT could detect more small lesions than MRI. CT is not more superior modality than MRI untill ICT is performed. It is concluded ICT should be done when diagnosing small hepatic tumors by CT. (author).

  18. CT of diffuse pulmonary diseases

    International Nuclear Information System (INIS)

    Itoh, Harumi; Murata, Kiyoshi; Todo, Giro

    1987-01-01

    While the theory of chest radiographic interpretation in diagnosing diffuse pulmonary diseases has not yet been established, X-ray computed tomography (CT), having intrinsic high contrast resolution and improved spatial resolution, has proved to offer important imformation concerning the location and invasion of diffuse pulmonary lesions. This study related to CT-pathologic correlation, focusing on perivascular interstitial space and secondary pulmonary lobule at macroscopic levels. The perivascular interstitial space was thickened as a result of the infiltration of cancer, granulomas, and inflammatory cells. This finding appeared as irregular contour of the blood vessel on CT. Centrilobular nodules were distributed at the tip of the bronchus or pulmonary artery on CT. The distance from the terminal and respiratory bronchioles to the lobular border was 2 to 3 mm. Lobular lesions were delineated as clear margin on CT. Contribution of these CT features to chest radiographic interpretation must await further studies. (Namekawa, K.)

  19. A simulation study on proton computed tomography (CT) stopping power accuracy using dual energy CT scans as benchmark

    DEFF Research Database (Denmark)

    Hansen, David Christoffer; Seco, Joao; Sørensen, Thomas Sangild

    2015-01-01

    Background. Accurate stopping power estimation is crucial for treatment planning in proton therapy, and the uncertainties in stopping power are currently the largest contributor to the employed dose margins. Dual energy x-ray computed tomography (CT) (clinically available) and proton CT (in...... development) have both been proposed as methods for obtaining patient stopping power maps. The purpose of this work was to assess the accuracy of proton CT using dual energy CT scans of phantoms to establish reference accuracy levels. Material and methods. A CT calibration phantom and an abdomen cross section...... phantom containing inserts were scanned with dual energy and single energy CT with a state-of-the-art dual energy CT scanner. Proton CT scans were simulated using Monte Carlo methods. The simulations followed the setup used in current prototype proton CT scanners and included realistic modeling...

  20. Hydro-geomechanical behaviour of gas-hydrate bearing soils during gas production through depressurization and CO2 injection

    Science.gov (United States)

    Deusner, C.; Gupta, S.; Kossel, E.; Bigalke, N.; Haeckel, M.

    2015-12-01

    Results from recent field trials suggest that natural gas could be produced from marine gas hydrate reservoirs at compatible yields and rates. It appears, from a current perspective, that gas production would essentially be based on depressurization and, when facing suitable conditions, be assisted by local thermal stimulation or gas hydrate conversion after injection of CO2-rich fluids. Both field trials, onshore in the Alaska permafrost and in the Nankai Trough offshore Japan, were accompanied by different technical issues, the most striking problems resulting from un-predicted geomechanical behaviour, sediment destabilization and catastrophic sand production. So far, there is a lack of experimental data which could help to understand relevant mechanisms and triggers for potential soil failure in gas hydrate production, to guide model development for simulation of soil behaviour in large-scale production, and to identify processes which drive or, further, mitigate sand production. We use high-pressure flow-through systems in combination with different online and in situ monitoring tools (e.g. Raman microscopy, MRI) to simulate relevant gas hydrate production scenarios. Key components for soil mechanical studies are triaxial systems with ERT (Electric resistivity tomography) and high-resolution local strain analysis. Sand production control and management is studied in a novel hollow-cylinder-type triaxial setup with a miniaturized borehole which allows fluid and particle transport at different fluid injection and flow conditions. Further, the development of a large-scale high-pressure flow-through triaxial test system equipped with μ-CT is ongoing. We will present results from high-pressure flow-through experiments on gas production through depressurization and injection of CO2-rich fluids. Experimental data are used to develop and parametrize numerical models which can simulate coupled process dynamics during gas-hydrate formation and gas production.

  1. A simulation study on proton computed tomography (CT) stopping power accuracy using dual energy CT scans as benchmark.

    Science.gov (United States)

    Hansen, David C; Seco, Joao; Sørensen, Thomas Sangild; Petersen, Jørgen Breede Baltzer; Wildberger, Joachim E; Verhaegen, Frank; Landry, Guillaume

    2015-01-01

    Accurate stopping power estimation is crucial for treatment planning in proton therapy, and the uncertainties in stopping power are currently the largest contributor to the employed dose margins. Dual energy x-ray computed tomography (CT) (clinically available) and proton CT (in development) have both been proposed as methods for obtaining patient stopping power maps. The purpose of this work was to assess the accuracy of proton CT using dual energy CT scans of phantoms to establish reference accuracy levels. A CT calibration phantom and an abdomen cross section phantom containing inserts were scanned with dual energy and single energy CT with a state-of-the-art dual energy CT scanner. Proton CT scans were simulated using Monte Carlo methods. The simulations followed the setup used in current prototype proton CT scanners and included realistic modeling of detectors and the corresponding noise characteristics. Stopping power maps were calculated for all three scans, and compared with the ground truth stopping power from the phantoms. Proton CT gave slightly better stopping power estimates than the dual energy CT method, with root mean square errors of 0.2% and 0.5% (for each phantom) compared to 0.5% and 0.9%. Single energy CT root mean square errors were 2.7% and 1.6%. Maximal errors for proton, dual energy and single energy CT were 0.51%, 1.7% and 7.4%, respectively. Better stopping power estimates could significantly reduce the range errors in proton therapy, but requires a large improvement in current methods which may be achievable with proton CT.

  2. Acute pancreatitis: clinical vs. CT findings

    International Nuclear Information System (INIS)

    Hill, M.C.; Barkin, J.; Isikoff, M.B.; Silver stein, W.; Kalser, M.

    1982-01-01

    In a prospective study of 91 patients with acute pancreatitis, computed tomographic (CT) findings were correlated with the clinical type of acute pancreatitis. In acute edematous pancreatitis (63 patients; 16 with repeat CT), CT was normal (28%) or showed inflammation limited to the pancreas (61%). Phlegmonous changes were present in 11%, including one patient with focal pancreatic hemorrhage, indicating that clinically unsuspected hemorrhagic pancreatitis can occur. In acute necrotizing (hemorrhagic, suppurative) pancreatitis (nine patients; eight with repeat CT), no patient had a normal CT scan and 89% had phlegmonous changes. One patient had hemorrhagic pancreatitis and three had abscesses. In acute exacerbation of chronic pancreatitis (10 patients; three with repeat CT), there were pancreatic calcifications (70%), a focal mass (40%), and pancreatic ductal dilation (30%). On follow-up CT, the findings of acute pancreatitis did not always disappear with resolution of the clinical symptons. This was especialy true of phlegmonous pancreatitis, where the CT findings could persist for months

  3. Multidetector CT of the colon

    International Nuclear Information System (INIS)

    Luboldt, W.; Hoepffner, N.; Holzer, K.

    2003-01-01

    Multidetector technology, enabling faster imaging, higher spatial resolution and reduction in radiation dose, increases the role of CT in colonic diagnostic. The higher spatial resolution in the z-direction also changes the way to analyze the images. Instead of reading axial sections, now the colon can be systematically assessed in 3D by scrolling through multiplanar reconstructions or in CT colonography by virtual endoscopy. With ongoing improvements in computer-aided diagnosis CT colonography becomes an alternative to fiberoptic colonocopy for screening (http://www.multiorganscreening.org). In this article we propose a CT examination protocol for the colon, describe the typical imaging findings of different colonic diseases, and summarize the current status of CT colonography. (orig.)

  4. CT examination of the kidneys

    International Nuclear Information System (INIS)

    Handa, Youji; Ishida, Ken; Arita, Takeshi; Ishine, Kenji; Tezen, Takashi; Ohta, Nobuhiro

    1985-01-01

    Plain CT scanning of the kidney was performed in 16 patients with renal failure whose basic renal disorder had been not necessarily known beforehand. The findings of the CT examination were composed of renal atrophy of various degree (12 cases), cystic lesions (8 cases), polycystic renal disease (one case), nephrosclerosis (2 cases), hydronephrosis (2 cases), ureter and renal stones (one case), and normal CT profile (2 cases). Being based on these CT findings and other clinical informations, basic renal disorders could be either presumed or confirmed. It was concluded that plain CT scanning of the kidney was useful to decide a method of treatment and to estimate prognosis in patients with renal failure. (author)

  5. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT ...

  6. Do SNOMED CT Relationships Qualify?

    NARCIS (Netherlands)

    Cornet, Ronald

    2008-01-01

    An important feature of SNOMED CT is post-coordination, which is enabled as SNOMED CT specifies refinability of target concepts of relationships. In this paper the use of refinable relationships in SNOMED CT is analysed, and the interplay between refinable and defining relationships. Refinability is

  7. CT fluoroscopy-guided vs. multislice CT biopsy mode-guided lung biopsies: Accuracy, complications and radiation dose

    International Nuclear Information System (INIS)

    Prosch, Helmut; Stadler, Alfred; Schilling, Matthias; Bürklin, Sandra; Eisenhuber, Edith; Schober, Ewald; Mostbeck, Gerhard

    2012-01-01

    Background: The aim of this retrospective study was to compare the diagnostic accuracy, the frequency of complications, the duration of the interventions and the radiation doses of CT fluoroscopy (CTF) guided biopsies of lung lesions with those of multislice CT (MS-CT) biopsy mode-guided biopsies. Methods: Data and images from 124 consecutive patients undergoing CTF-guided lung biopsy (group A) and 132 MS-CT-biopsy mode-guided lung biopsy (group B) were reviewed. CTF-guided biopsies were performed on a Siemens Emotion 6 CT scanner with intermittent or continuous CT-fluoroscopy, MS-CT biopsy mode-guided biopsies were performed on a Siemens Emotion 16 CT scanner. All biopsies were performed with a coaxial needle technique. Results: The two groups (A vs. B) did not differ significantly regarding sensitivity (95.5% vs. 95.9%), specificity (96.7% vs. 95.5%), negative predictive value (87.9% vs. 84%) or positive predictive value (98.8% vs. 98.9%). Pneumothorax was observed in 30.0% and 32.5% of the patients, respectively. Chest tube placement was necessary in 4% (group A) and 13% (group B) of the patients. The duration of the intervention was significantly longer in group A (median 37 min vs. 32 min, p = 0.04). The mean CT dose index (CTDI) was 422 in group A and 36.3 in group B (p < 0.001). Conclusion: Compared to CTF-guided biopsies, chest biopsies using the MS-CT biopsy mode show dramatically lower CTDI levels. Although the diagnostic yield of the procedures do not differ significantly, biopsies using the MS-CT-biopsy mode have a three-fold higher rate of chest tube placement.

  8. {sup 18}F-FDG PET/CT and contrast-enhanced CT findings of pulmonary cryptococcosis

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Si-yun, E-mail: wang_shuxia@outlook.com [Department of PET Center, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Chen, Gang, E-mail: cgggh@outlook.com [Department of Thoracic Surgery, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Luo, Dong-lan, E-mail: 695532870@qq.com [Department of Pathology, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Shao, Dan, E-mail: shaodan501@outlook.com [Department of PET Center, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Liu, En-tao, E-mail: GDGH2015@gmail.com [Department of PET Center, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Sun, Taotao, E-mail: sunmoodsdaisy@bjmu.edu.cn [Department of PET Center, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Wang, Shu-Xia, E-mail: wsyggh@outlook.com [Department of PET Center, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China)

    2017-04-15

    Purpose: Pulmonary cryptococcosis is an uncommon cause of pulmonary nodules in non-AIDS patients. This study reports the {sup 18}F-fluorodeoxyglucose-positron emission tomography ({sup 18}F-FDG PET/CT) and contrast-enhanced CT (CE-CT) findings of 42 patients with pulmonary cryptococcosis. Materials and methods: A retrospective review of the {sup 18}F-FDG PET/CT and CE-CT findings of 42 patients with histologically proven pulmonary cryptococcosis was conducted. All patients underwent PET/CT and CE-CT in the same session. The CT diagnosis was based on the location, morphological features, and enhancement of lesions. The PET/CT findings were recorded, and clinical data and surgical and histopathological findings were collected. Results: The results of the PET scans revealed that 37 (88%) of 42 patients showed higher FDG uptake, and 5 (12%) patients demonstrated lower FDG uptake than the mediastinal blood pool. The maximum standardized uptake value (SUV) of pulmonary cryptococcosis ranged from 1.4 to 13.0 (average: 5.7 ± 3.3, median 4.9). A single nodular pattern was the most prevalent pattern observed and was found in 29 (69%) patients. This pattern was followed by scattered nodular (n = 4, 10%), clustered nodular (n = 3, 7%), mass-like (n = 3, 7%), and bronchopneumonic (n = 3, 7%) patterns. The most frequent pattern of immunocompetent patients was the single nodular pattern (29 of 33, 88%). Immunocompromised patients most frequently pattern exhibited mass-like (3 of 9, 33%) and bronchopneumonic (3 of 9, 33%) patterns. Conclusion: Pulmonary cryptococcosis most commonly appears as single nodules in immunocompetent patients. Mass-like and bronchopneumonic patterns were common in immunocompromised patients. In 88% of patients, lung lesions showed high FDG uptake, thus mimicking a possible malignant condition.

  9. Reduction of rectal doses by removal of gas in the rectum during vaginal cuff brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Sabater, S.; Sevillano, M.M.; Andres, I.; Berenguer, R. [Complejo Hospitalario Univ. de Albacete (CHUA) (Spain). Dept. of Radiation Oncology; Machin-Hamalainen, S. [C.S. General Ricardos, Madrid (Spain); Mueller, K.; Arenas, M. [Hospital Univ. Sant Joan, Reus (Spain). Dept. of Radiation Oncology

    2013-11-15

    Objective: The goal of this work was to evaluate whether the volume reduction related to removal of gas in the rectum could be translated in lower doses to organs at risk (OAR) during vaginal cuff brachytherapy (VBT). Material and methods: Fourteen pairs of brachytherapy planning CT scans derived from 11 patients were re-segmented and re-planned using the same parameters. The only difference between pairs of CTs was the presence or lack of gas in the rectum. The first CT showed the basal status and the second was carried out after gas removal with a tube. A set of values derived from bladder and rectum dose-volume histograms (DVH) and dose-surface histograms (DSH) were extracted. Moreover the cylinder position related to the patient craniocaudal axis was recorded. Results: Rectum volume decreased significantly from 77.8 {+-} 45 to 55.43 {+-} 17.6 ml (p = 0.0052) after gas removal. Such volume diminution represented a significant reduction on all rectal DVH parameters analyzed except D{sub 25%} and D{sub 50%}. DSH parameter results were similar to previous ones. A nonsignificant increase of the bladder volume was observed and was associated with an increase of the DVH metrics analyzed. Conclusion: Removal of gas pockets is a simple and inexpensive maneuver that decreases rectal dose parameters on VBT, which can be translated as a better therapeutic ratio. It also suggests that other actions directed to empty the rectum could have a similar effect. (orig.)

  10. Dose performance and image quality: Dual source CT versus single source CT in cardiac CT angiography

    International Nuclear Information System (INIS)

    Wang Min; Qi Hengtao; Wang Ximing; Wang Tao; Chen, Jiu-Hong; Liu Cheng

    2009-01-01

    Objective: To evaluate dose performance and image quality of 64-slice dual source CT (DSCT) in comparison to 64-slice single source CT (SSCT) in cardiac CT angiography (CTA). Methods: 100 patients examined by DSCT and 60 patients scanned by SSCT were included in this study. Objective indices such as image noise, contrast-to-noise ratio and signal-to-noise ratio were analyzed. Subjective image quality was assessed by two cardiovascular radiologists in consensus using a four-point scale (1 = excellent to 4 = not acceptable). Estimation of effective dose was performed on the basis of dose length product (DLP). Results: At low heart rates ( 0.05), but, at high heart rates (>70 bpm), DSCT provided robust image quality (P 70 bpm), DSCT is able to provide robust diagnostic image quality at doses far below that of SSCT.

  11. Early small-bowel ischemia: dual-energy CT improves conspicuity compared with conventional CT in a swine model.

    Science.gov (United States)

    Potretzke, Theodora A; Brace, Christopher L; Lubner, Meghan G; Sampson, Lisa A; Willey, Bridgett J; Lee, Fred T

    2015-04-01

    To compare dual-energy computed tomography (CT) with conventional CT for the detection of small-bowel ischemia in an experimental animal model. The study was approved by the animal care and use committee and was performed in accordance with the Guide for Care and Use of Laboratory Animals issued by the National Research Council. Ischemic bowel segments (n = 8) were created in swine (n = 4) by means of surgical occlusion of distal mesenteric arteries and veins. Contrast material-enhanced dual-energy CT and conventional single-energy CT (120 kVp) sequences were performed during the portal venous phase with a single-source fast-switching dual-energy CT scanner. Attenuation values and contrast-to-noise ratios of ischemic and perfused segments on iodine material-density, monospectral dual-energy CT (51 keV, 65 keV, and 70 keV), and conventional 120-kVp CT images were compared. Linear mixed-effects models were used for comparisons. The attenuation difference between ischemic and perfused segments was significantly greater on dual-energy 51-keV CT images than on conventional 120-kVp CT images (mean difference, 91.7 HU vs 47.6 HU; P conventional CT by increasing attenuation differences between ischemic and perfused segments on low-kiloelectron volt and iodine material density images. © RSNA, 2014.

  12. Chest Computed Tomography (CT) Immediately after CT-Guided Transthoracic Needle Aspiration Biopsy as a Predictor of Overt Pneumothorax

    Science.gov (United States)

    Noh, Tae June; Lee, Chang Hoon; Kang, Young Ae; Kwon, Sung-Youn; Yoon, Ho-Il; Kim, Tae Jung; Lee, Kyung Won; Lee, Jae Ho

    2009-01-01

    Background/Aims This study examined the correlation between pneumothorax detected by immediate post-transthoracic needle aspiration-biopsy (TTNB) chest computed tomography (CT) and overt pneumothorax detected by chest PA, and investigated factors that might influence the correlation. Methods Adult patients who had undergone CT-guided TTNB for lung lesions from May 2003 to June 2007 at Seoul National University Bundang Hospital were included. Immediate post-TTNB CT and chest PA follow-up at 4 and 16 hours after CT-guided TTNB were performed in 934 patients. Results Pneumothorax detected by immediate chest CT (CT-pneumothorax) was found in 237 (25%) and overt pneumothorax was detected by chest PA follow-up in 92 (38.8%) of the 237 patients. However, overt pneumothorax was found in 18 (2.6%) of the 697 patients without CT-pneumothorax. The width and depth of CT-pneumothorax were predictive risk factors for overt pneumothorax. Conclusions CT-pneumothorax is very sensitive for predicting overt pneumothorax, and the width and depth on CT-pneumothorax are reliable risk factors for predicting overt pneumothorax. PMID:19949733

  13. Dynamic CT of the renal parenchyma

    International Nuclear Information System (INIS)

    Ohyama, Yukio; Imanishi, Yoshimasa; Ishikawa, Tohru; Fujii, Masamichi; Uji, Teruyuki

    1985-01-01

    Normal renal dynamic CT findings of 57 cases were analysed in termes of sequential change of renal parenchymal CT image. Cortex, outer medulla and inner medulla were delineated and their sequential CT image was well correlated with the anatomicophysiological character of the kidney. Dynamic CT of 32 abnormal cases showed abnormal sequential CT findings explaining the mechanism of the abnormalities. Especially, delayed enhancement of renal cortex was noted in 17 of 19 kidneys with arterial obstruction and delayed enhancement of renal medulla in 22 of 25 cases with renal dysfunction. Compaired with excretory urography in 11 cases with renal dysfunction, advantage of dynamic CT were noted. (author)

  14. Methods of in-vivo mouse lung micro-CT

    Science.gov (United States)

    Recheis, Wolfgang A.; Nixon, Earl; Thiesse, Jacqueline; McLennan, Geoffrey; Ross, Alan; Hoffman, Eric

    2005-04-01

    Micro-CT will have a profound influence on the accumulation of anatomical and physiological phenotypic changes in natural and transgenetic mouse models. Longitudinal studies will be greatly facilitated, allowing for a more complete and accurate description of events if in-vivo studies are accomplished. The purpose of the ongoing project is to establish a feasible and reproducible setup for in-vivo mouse lung micro-computed tomography (μCT). We seek to use in-vivo respiratory-gated μCT to follow mouse models of lung disease with subsequent recovery of the mouse. Methodologies for optimizing scanning parameters and gating for the in-vivo mouse lung are presented. A Scireq flexiVent ventilated the gas-anesthetized mice at 60 breaths/minute, 30 cm H20 PEEP, 30 ml/kg tidal volume and provided a respiratory signal to gate a Skyscan 1076 μCT. Physiologic monitoring allowed the control of vital functions and quality of anesthesia, e.g. via ECG monitoring. In contrary to longer exposure times with ex-vivo scans, scan times for in-vivo were reduced using 35μm pixel size, 158ms exposure time and 18μm pixel size, 316ms exposure time to reduce motion artifacts. Gating via spontaneous breathing was also tested. Optimal contrast resolution was achieved at 50kVp, 200μA, applying an aluminum filter (0.5mm). There were minimal non-cardiac related motion artifacts. Both 35μm and 1μm voxel size images were suitable for evaluation of the airway lumen and parenchymal density. Total scan times were 30 and 65 minutes respectively. The mice recovered following scanning protocols. In-vivo lung scanning with recovery of the mouse delivered reasonable image quality for longitudinal studies, e.g. mouse asthma models. After examining 10 mice, we conclude μCT is a feasible tool evaluating mouse models of lung pathology in longitudinal studies with increasing anatomic detail available for evaluation as one moves from in-vivo to ex-vivo studies. Further developments include automated

  15. Opportunities for new CT contrast agents to maximize the diagnostic potential of emerging spectral CT technologies.

    Science.gov (United States)

    Yeh, Benjamin M; FitzGerald, Paul F; Edic, Peter M; Lambert, Jack W; Colborn, Robert E; Marino, Michael E; Evans, Paul M; Roberts, Jeannette C; Wang, Zhen J; Wong, Margaret J; Bonitatibus, Peter J

    2017-04-01

    The introduction of spectral CT imaging in the form of fast clinical dual-energy CT enabled contrast material to be differentiated from other radiodense materials, improved lesion detection in contrast-enhanced scans, and changed the way that existing iodine and barium contrast materials are used in clinical practice. More profoundly, spectral CT can differentiate between individual contrast materials that have different reporter elements such that high-resolution CT imaging of multiple contrast agents can be obtained in a single pass of the CT scanner. These spectral CT capabilities would be even more impactful with the development of contrast materials designed to complement the existing clinical iodine- and barium-based agents. New biocompatible high-atomic number contrast materials with different biodistribution and X-ray attenuation properties than existing agents will expand the diagnostic power of spectral CT imaging without penalties in radiation dose or scan time. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Liver trauma from penetrating injuries. Miscellanea, personal series, clinical and CT findings

    International Nuclear Information System (INIS)

    Salzano, A.; Nocera, V.; De Rosa, A.; Vigliotti, A.; Rossi, E.; Carbone, M.; Gatta, G.

    2000-01-01

    the extent and severity of damage, which permits to choose a conservative treatment in case of intraparenchymal hematomas and lacerocontusive foci without hemoperitoneum, which can be followed-up with physical and CT examinations. Moreover, Helical CT could provide the early diagnosis of active bleeding in the peritoneum and of focal bleeding in the liver, thus permitting prompt hepatorrraphy or targeted hepatectomy. A diaphragm injury suspected at CT should always prompt the surgeon to intervention, especially when hemothorax, lung base pneumothorax, large liver hematoma or tear of the liver dome are associated. Finally, subdiaphragmatic free gas indicates gut perforation associated with liver damage, in which case surgery is necessary too [it

  17. Automated size-specific CT dose monitoring program: Assessing variability in CT dose

    International Nuclear Information System (INIS)

    Christianson, Olav; Li Xiang; Frush, Donald; Samei, Ehsan

    2012-01-01

    Purpose: The potential health risks associated with low levels of ionizing radiation have created a movement in the radiology community to optimize computed tomography (CT) imaging protocols to use the lowest radiation dose possible without compromising the diagnostic usefulness of the images. Despite efforts to use appropriate and consistent radiation doses, studies suggest that a great deal of variability in radiation dose exists both within and between institutions for CT imaging. In this context, the authors have developed an automated size-specific radiation dose monitoring program for CT and used this program to assess variability in size-adjusted effective dose from CT imaging. Methods: The authors radiation dose monitoring program operates on an independent health insurance portability and accountability act compliant dosimetry server. Digital imaging and communication in medicine routing software is used to isolate dose report screen captures and scout images for all incoming CT studies. Effective dose conversion factors (k-factors) are determined based on the protocol and optical character recognition is used to extract the CT dose index and dose-length product. The patient's thickness is obtained by applying an adaptive thresholding algorithm to the scout images and is used to calculate the size-adjusted effective dose (ED adj ). The radiation dose monitoring program was used to collect data on 6351 CT studies from three scanner models (GE Lightspeed Pro 16, GE Lightspeed VCT, and GE Definition CT750 HD) and two institutions over a one-month period and to analyze the variability in ED adj between scanner models and across institutions. Results: No significant difference was found between computer measurements of patient thickness and observer measurements (p= 0.17), and the average difference between the two methods was less than 4%. Applying the size correction resulted in ED adj that differed by up to 44% from effective dose estimates that were not

  18. CT diagnostic significance of tuboovarian abscess

    International Nuclear Information System (INIS)

    Du Tieqiao; Dong Jie; Xu Quanying; An Haiqin; Sang Chunyu

    2006-01-01

    Objective: To analyze computed tomographic (CT) imaging features of tuboovarian abscess as well as to discuss CT diagnostic significance. Methods: Ten patients with tuboovarian abscess were performed CT enhancing scans. Results: Ten patients manifested thick-walled, cystic-solid complex adnexal mass and indistinct margins on CT imaging. Internal thick septations and layered enhancement of the mass border on CT contrast images were common. Associated findings of CT included thickening of' the uterosacral ligaments in 9 of 10 patients, increased attenuation of the presacral and perirectal fat secondary to edema in 9 patients, serpiginous structure corresponding to a dilated, pus-filled fallopian tube in 6 patients and fluid-filled within uterine cavity in 4 patients. On CT scans, the inflammatory infiltration of adnexal abscesses involved pelvic structure included adhesion with borders of uterus in 9 patients, adhesion with rectal or sigmoid in 4 patients and pelvic wall or bowel loop in 3 patients. Two cases with peritoneal thicken showed ascites on CT images and right adnexal tuboovarian abscess in 2 patients were associated with appendicitis. Conclusion: CT can reveal pelvic adjacent organs involvement or adhesion and inflammatory infihration of pelvic floor soft-tissues or fascial planes except showing cystic solid complex mass of adnexal location so that indicating characteristics and the extent of the suspected pelvic inflammatory diseases. CT can be valuable in difficult cases of gynecologic infective diseases. (authors)

  19. CT findings in acute small bowel diverticulitis; Computertomographie bei akuter Duenndarmdivertikulitis

    Energy Technology Data Exchange (ETDEWEB)

    Ferstl, F.J.; Obert, R. [Radiologisch-Nuklearmedizinisches Zentrum (RNZ) am St. Theresienkrankenhaus Nuernberg (Germany)

    2004-02-01

    Small bowel diverticulitis is a rare cause of an acute abdomen. Originating from acquired diverticula of the jejunum, less often of the ileum, or Meckel diverticulum, the symptoms are non-specific, simulating other acute inflammatory disorders, such as appendicitis, cholecystitis or colonic diverticulitis. The diagnosis of small bowel diverticulitis is solely based on radiologic findings, with computed tomography (CT) regarded as the method of choice. In recent years, a number of case reports have described the spectrum of the CT features in acute small bowel diverticulitis and its dependence on the severity of the inflammatory process. Typical findings are an inflamed diverticulum, inflammatory mesenteric infiltration, extraluminal gas collection and mural edema of adjacent small bowel loops with resultant separation of bowel loops. An enterolith is rarely found in an inflamed diverticulum. Complications include abscesses, fistulae, small bowel obstruction and free perforation with peritonitis. Small bowel diverticulitis can be a diagnostic problem if it involves the terminal ileum or Meckel's diverticulum. For preoperative confirmation of the presumed diagnosis of small bowel diverticulitis on CT, an enteroclysis for acquired diverticula or a technetium scan for Meckel's diverticulum should be performed. We present the CT findings in three patients of acute small bowel diverticulitis, two affecting the jejunum and one a Meckel's diverticulum. (orig.) [German] Die akute Duenndarmdivertikulitis ist eine seltene Ursache eines akuten Abdomens. Ausgehend von den erworbenen Divertikeln des Jejunums, seltener des Ileums, oder von einem Meckel-Divertikel, manifestiert sich die Divertikulitis klinisch durch eine unspezifische Symptomatik, die zuerst an die haeufigeren, akutentzuendlichen Erkrankungen des Abdomens wie z. B. Appendizitis, Cholezystitis oder Kolondivertikulitis denken laesst. Die Duenndarmdivertikulitis kann praeoperativ nur durch

  20. Correlation of CT perfusion and CT volumetry in patients with Alzheimers disease

    International Nuclear Information System (INIS)

    Czarnecka, A.; Zimny, A.; Sasiadek, M.

    2010-01-01

    Background: Both brain atrophy and decrease of perfusion are observed in dementive diseases. The aim of the study was to correlate the results of brain perfusion CT (pCT) and CT volumetry in patients with Alzheimers disease (AD). Material/Methods: Forty-eight patients with AD (mean age of 71.3 years) underwent brain pCT and CT volumetry. The pCT was performed at the level of basal ganglia after the injection of contrast medium (50 ml, 4 ml/sec.) with serial scanning (delay 7 sec, 50 scans, 1 scan/sec). Volumetric measurements were carried out on the basis of source images, with the use of a dedicated CT software combined with manual outlining of the regions of interest in extracerebral and intraventricular CSF spaces. Perfusion parameters of the cerebral blood flow (CBF) and cerebral blood volume (CBV) from the grey matter of frontal and temporal as well as basal ganglia were compared statistically with the volumetric measurements of frontal and temporal cortical atrophy as well as subcortical atrophy. Results: A statistically significant positive correlation was found between the values of CBF and CBV in the basal ganglia and the volumes of the lateral and third ventricles. The comparison of CBF and CBV results with the volumetric measurements in the areas of the frontal and temporal lobes showed mostly negative correlations, but none of them was of statistical significance. Conclusions: In patients with AD, the degree of cortical atrophy is not correlated with the decrease of perfusion in the grey matter and subcortical atrophy is not correlated with the decrease of perfusion in the basal ganglia region. It suggests that functional and structural changes in AD are not related to each other. (authors)

  1. Value of CT scan in synovial diseases

    International Nuclear Information System (INIS)

    Tamisier, J.N.; Regent, D.; Thomas, P.; Pere, P.; Gaucher, A.; Capesius, P.

    1986-01-01

    The authors have developed a technique of CT arthroscan which, by the use of a gas or opaque contrast medium, is able to demonstrate the synovial structures of the knee, the shoulder and the hip. Among the essential indications, they include the demonstration of neoplasia of the synovium and the evaluation of the pannus in rheumatoid arthritis. Their secondary indications include the demonstration of fluid effusions in the hip, the precise evaluation of hyperostotic lesions in the same joint, the detection of ossification phenomena in the capsule of the inter-apophyseal joints in ankylosing spondylitis and, in some cases, following negative or doubtful arthrography for the detection of synovial plica. They also recall the usefulness or the arthroscan in the diagnosis of lesions of the labrum glenoidale [fr

  2. Brain tumor and CT, 1. Relationship between the consistency of a brain tumor and the CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, N.; Katada, K.; Shinomiya, Y.; Sano, H.; Kanno, T. (Fujita Gakuen Univ., School of Medicine, Toyoake, Aichi (Japan))

    1981-08-01

    It is very important for a neurosurgeon to know the consistency of a brain tumor preoperatively, since the information is of much use in indicating the likely difficulty of the operation, which operative tools should be selected, the amount of bleeding to be expected from the tumor, and so on. The authors, therefore, tried to evaluate the consistency of brain tumors preoperatively. Twenty-seven cases in which the margin of the tumor was made clear with a homogeneous stain were studied concerning the relationship between the tumor consistency and the CT findings. The results are as follows: 1) A higher CT number on a plain CT indicated a harder consistency of the tumor. 2) A lesser contrast index (CT number on enhancement CT/CT number on plain CT) showed a harder consistency of the tumor.

  3. Effects of gas produced by degradation of Mg–Zn–Zr Alloy on cancellous bone tissue

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jingbo; Jiang, Hongfeng [Tianjin Hospital, 300211 Tianjin (China); Bi, Yanze; Sun, Jin e; Chen, Minfang; Liu, Debao [School of Materials Science and Engineering, Tianjin University of Technology, 300384 Tianjin (China)

    2015-10-01

    Mg–Zn–Zr alloy cylinders were implanted into the femoral condyles of Japanese big-ear white rabbits. X-ray showed that by 12 weeks following implantation the implant became obscure, around which the low-density area appeared and enlarged. By 24 weeks, the implant was more obscure and the density of the surrounding cancellous bone increased. Scanning electron microscopy examination showed bone tissue on the surface of the alloy attached by living fibers at 12 weeks. Micro-CT confirmed that new bone tissue on the surface of the residual alloy implant increased from 12 weeks to 24 weeks. By 12 weeks, many cavities in the cancellous bone tissue around the implant were noted with a CT value, similar to gas value, and increasing by 24 weeks (P < 0.01). Histological examination of hard tissue slices showed that bone tissue was visibly attached to the alloy in the femoral condyle at 12 weeks. The trabecular bone tissues became more intact and dense, and the cavities were filled with soft tissue at 24 weeks. In general, gas produced by the degradation of the Mg–Zn–Zr alloy can cause cavitation within cancellous bone, which does not affect osteogenesis of Mg alloy. - Highlights: • The degradation of Mg alloy in cancellous bone causes cavitation around the alloy. • At first, the CT value of the cavities is similar to the gas value. • The area of the cavities enlarges gradually by 12 weeks. • The cavities are filled with bone tissue and soft tissue gradually.

  4. CT evaluation of acetabular fractures

    Energy Technology Data Exchange (ETDEWEB)

    Piazza, P; Girelli, G; Coran, F; Lutman, M

    1986-01-01

    The paper deals with sixteen cases of acetabular fractures studied with CT. After a short description of the normal CT findings, the different kind of fractures are reported. The usefulness of CT examination in evaluating acetabular fractures and their complications is confirmed both in conservative treatment and surgical approach.

  5. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Stroke Brain Tumors Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  6. SU-E-T-70: Commissioning a Multislice CT Scanner for X-Ray CT Polymer Gel Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Johnston, H [University of Victoria, Victoria, BC (Australia); UT Southwestern Medical Center, Dallas, TX (United States); Hilts, M [University of Victoria, Victoria, BC (Australia); BC Cancer Agency, Kelowna, BC (Australia); Jirasek, A [University of Victoria, Victoria, BC (Australia)

    2014-06-01

    Purpose: To commission a multislice computed tomography (CT) scanner for fast and reliable readout of radiation therapy (RT) dose distributions using CT polymer gel dosimetry (PGD). Methods: Commissioning was performed for a 16-slice CT scanner using images acquired through a 1L cylinder filled with water. Additional images were collected using a single slice machine for comparison purposes. The variability in CT number associated with the anode heel effect was evaluated and used to define a new slice-by-slice background image subtraction technique. Image quality was assessed for the multislice system by comparing image noise and uniformity to that of the single slice machine. The consistency in CT number across slices acquired simultaneously using the multislice detector array was also evaluated. Finally, the variability in CT number due to increasing x-ray tube load was measured for the multislice scanner and compared to the tube load effects observed on the single slice machine. Results: Slice-by-slice background subtraction effectively removes the variability in CT number across images acquired simultaneously using the multislice scanner and is the recommended background subtraction method when using a multislice CT system. Image quality for the multislice machine was found to be comparable to that of the single slice scanner. Further study showed CT number was consistent across image slices acquired simultaneously using the multislice detector array for each detector configuration of the slice thickness examined. In addition, the multislice system was found to eliminate variations in CT number due to increasing x-ray tube load and reduce scanning time by a factor of 4 when compared to imaging a large volume using a single slice scanner. Conclusion: A multislice CT scanner has been commissioning for CT PGD, allowing images of an entire dose distribution to be acquired in a matter of minutes. Funding support provided by the Natural Sciences and Engineering

  7. Results and complications of CT-guided biopsy with CT fluoroscopy

    International Nuclear Information System (INIS)

    Saika, Yoshinori; Ogura, Yasuharu; Doi, Kenji; Misaki, Toshimasa; Shimizu, Masashi; Narabayashi, Isamu

    2002-01-01

    We studied the results and complications of CT-guided biopsy with CT fluoroscopy performed 66 lesions in 64 patients from March 1999 to February 2001. In addition to the conventional procedure of CT-guided biopsy, we use CT fluoroscopy for confirmation of the location of the tip of the biopsy needle and the accurate contact, in some cases, at the time of puncturing. Examination results showed malignancy in 36 lesions and benign findings in 30 lesions. The sensitivity was 85.7%, specificity was 100.0%, and accuracy was 90.9%. Pneumothorax occurred in 20 out of 64 patients (31.3%). In a study on 26 small lesions (≤2 cm) in 25 patients, the sensitivity was 81.8%, specificity was 100.0%, accuracy was 92.3%. Pneumothorax occurred in 12 out of 25 patients (48.0%), more frequently than in patients with large lesions. In a study on 6 false negative cases, they tended to be intrapulmonary on location, small in diameter, and far from the skin puncture point. Examination results were satisfactory, especially in terms of accuracy in small lesions (≤2 cm). However, when the lesions were small, pneumothorax occurred frequently (48.0%). (author)

  8. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... vessels. CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT is less sensitive to patient movement ...

  9. CT diagnosis of cystic ovarian lesions

    International Nuclear Information System (INIS)

    Iio, Kazuto; Shinmura, Ryoji; Arima, Naomi; Yamada, Eiichiro; Ohkubo, Koichi; Nagata, Yukihiro

    1985-01-01

    CT was undertaken and CT numbers were measured in 47 patients with cystic ovarian lesions. CT features particularly for chocolate cyst revealed the uniform thickness of the whole cystic wall, findings suggesting adhesion to the surrounding organs, circular or oval shape, and higher CT numbers within the cyst than those in the other cystic ovarian lesions. However, because these features are not always observed in cases of chocolate cyst, one should not rely solely on CT findings in the diagnosis of chocolate cyst. (Namekawa, K.)

  10. Dynamic CT of hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, Nobuyuki; Shirato, Hiroki; Shinohara, Masahiro; Miyasaka, Kazuo; Morita, Yutaka; Irie, Goro

    1983-03-01

    We performed dynamic CT in 30 cases of hepatocellular carcinoma, and concluded as below. Detecting the stain in the early phase of the dynamic series, it is possible to make a diagnosis of hepatocellular carcinoma. The dynamic CT is effective in a case of small hepatocellular carcinoma in which it is difficult to gain an accurate diagnosis in the routine CT study. The dynamic CT is also effective in the differential diagnosis of hepatic lesions, as other hepatic lesions such as hemangioma and metastatic liver cancer show different patterns compared with hepatocellular carcinoma.

  11. (18)F-FDG PET-CT simulation for non-small-cell lung cancer: effect in patients already staged by PET-CT.

    Science.gov (United States)

    Hanna, Gerard G; McAleese, Jonathan; Carson, Kathryn J; Stewart, David P; Cosgrove, Vivian P; Eakin, Ruth L; Zatari, Ashraf; Lynch, Tom; Jarritt, Peter H; Young, V A Linda; O'Sullivan, Joe M; Hounsell, Alan R

    2010-05-01

    Positron emission tomography (PET), in addition to computed tomography (CT), has an effect in target volume definition for radical radiotherapy (RT) for non-small-cell lung cancer (NSCLC). In previously PET-CT staged patients with NSCLC, we assessed the effect of using an additional planning PET-CT scan for gross tumor volume (GTV) definition. A total of 28 patients with Stage IA-IIIB NSCLC were enrolled. All patients had undergone staging PET-CT to ensure suitability for radical RT. Of the 28 patients, 14 received induction chemotherapy. In place of a RT planning CT scan, patients underwent scanning on a PET-CT scanner. In a virtual planning study, four oncologists independently delineated the GTV on the CT scan alone and then on the PET-CT scan. Intraobserver and interobserver variability were assessed using the concordance index (CI), and the results were compared using the Wilcoxon signed ranks test. PET-CT improved the CI between observers when defining the GTV using the PET-CT images compared with using CT alone for matched cases (median CI, 0.57 for CT and 0.64 for PET-CT, p = .032). The median of the mean percentage of volume change from GTV(CT) to GTV(FUSED) was -5.21% for the induction chemotherapy group and 18.88% for the RT-alone group. Using the Mann-Whitney U test, this was significantly different (p = .001). PET-CT RT planning scan, in addition to a staging PET-CT scan, reduces interobserver variability in GTV definition for NSCLC. The GTV size with PET-CT compared with CT in the RT-alone group increased and was reduced in the induction chemotherapy group.

  12. 18F-FDG PET-CT Simulation for Non-Small-Cell Lung Cancer: Effect in Patients Already Staged by PET-CT

    International Nuclear Information System (INIS)

    Hanna, Gerard G.; McAleese, Jonathan; Carson, Kathryn J.; Stewart, David P.; Cosgrove, Vivian P.; Eakin, Ruth L.; Zatari, Ashraf; Lynch, Tom; Jarritt, Peter H.; Young, V.A. Linda D.C.R.; O'Sullivan, Joe M.

    2010-01-01

    Purpose: Positron emission tomography (PET), in addition to computed tomography (CT), has an effect in target volume definition for radical radiotherapy (RT) for non-small-cell lung cancer (NSCLC). In previously PET-CT staged patients with NSCLC, we assessed the effect of using an additional planning PET-CT scan for gross tumor volume (GTV) definition. Methods and Materials: A total of 28 patients with Stage IA-IIIB NSCLC were enrolled. All patients had undergone staging PET-CT to ensure suitability for radical RT. Of the 28 patients, 14 received induction chemotherapy. In place of a RT planning CT scan, patients underwent scanning on a PET-CT scanner. In a virtual planning study, four oncologists independently delineated the GTV on the CT scan alone and then on the PET-CT scan. Intraobserver and interobserver variability were assessed using the concordance index (CI), and the results were compared using the Wilcoxon signed ranks test. Results: PET-CT improved the CI between observers when defining the GTV using the PET-CT images compared with using CT alone for matched cases (median CI, 0.57 for CT and 0.64 for PET-CT, p = .032). The median of the mean percentage of volume change from GTV CT to GTV FUSED was -5.21% for the induction chemotherapy group and 18.88% for the RT-alone group. Using the Mann-Whitney U test, this was significantly different (p = .001). Conclusion: PET-CT RT planning scan, in addition to a staging PET-CT scan, reduces interobserver variability in GTV definition for NSCLC. The GTV size with PET-CT compared with CT in the RT-alone group increased and was reduced in the induction chemotherapy group.

  13. Cardiac cone-beam CT

    International Nuclear Information System (INIS)

    Manzke, Robert

    2005-01-01

    This doctoral thesis addresses imaging of the heart with retrospectively gated helical cone-beam computed tomography (CT). A thorough review of the CT reconstruction literature is presented in combination with a historic overview of cardiac CT imaging and a brief introduction to other cardiac imaging modalities. The thesis includes a comprehensive chapter about the theory of CT reconstruction, familiarizing the reader with the problem of cone-beam reconstruction. The anatomic and dynamic properties of the heart are outlined and techniques to derive the gating information are reviewed. With the extended cardiac reconstruction (ECR) framework, a new approach is presented for the heart-rate-adaptive gated helical cardiac cone-beam CT reconstruction. Reconstruction assessment criteria such as the temporal resolution, the homogeneity in terms of the cardiac phase, and the smoothness at cycle-to-cycle transitions are developed. Several reconstruction optimization approaches are described: An approach for the heart-rate-adaptive optimization of the temporal resolution is presented. Streak artifacts at cycle-to-cycle transitions can be minimized by using an improved cardiac weighting scheme. The optimal quiescent cardiac phase for the reconstruction can be determined automatically with the motion map technique. Results for all optimization procedures applied to ECR are presented and discussed based on patient and phantom data. The ECR algorithm is analyzed for larger detector arrays of future cone-beam systems throughout an extensive simulation study based on a four-dimensional cardiac CT phantom. The results of the scientific work are summarized and an outlook proposing future directions is given. The presented thesis is available for public download at www.cardiac-ct.net

  14. How to choose PET-CT or CT in the diagnosis and staging of lung cancer. Practical experience in China

    International Nuclear Information System (INIS)

    Jiang, T.; Tao, X.; Liu, H.; Liu, S.; Zheng, X.

    2010-01-01

    How to use CT and PET-CT rationally to raise diagnosis, staging and prognostic assessment of lung cancer to a higher level at the best cost-effect ratio is a subject that Chinese clinicians and radiologists should face conscientiously. We review the rational application of CT and PET-CT in four aspects of lung cancer, including screening and detection, morphologic evaluation, haemodynamic or metabolic feature evaluation, and follow-up, staging and prognostic evaluation. As PET-CT is only available in class III-A hospitals today, CT is the most popular equipment in China. PET-CT is more valuable only in cases where CT presentation of lung cancer is atypical or difficult to determine, or in cases where the diagnosis of lung cancer has been initially confirmed, for which clinical staging and decision concerning on therapeutic regimens are needed. We also recommend the current strategies of CT and PET-CT managing of SPN in China. (orig.)

  15. Non-invasive diagnostics of the maxillary and frontal sinuses based on diode laser gas spectroscopy.

    Science.gov (United States)

    Lewander, Märta; Lindberg, Sven; Svensson, Tomas; Siemund, Roger; Svanberg, Katarina; Svanberg, Sune

    2012-03-01

    Suspected, but objectively absent, rhinosinusitis constitutes a major cause of visits to the doctor, high health care costs, and the over-prescription of antibiotics, contributing to the serious problem of resistant bacteria. This situation is largely due to a lack of reliable and widely applicable diagnostic methods. A novel method for the diagnosis of rhinosinusitis based on non-intrusive diode laser gas spectroscopy is presented. The technique is based on light absorption by free gas (oxygen and water vapour) inside the sinuses, and has the potential to be a complementary diagnostic tool in primary health care. The method was evaluated on 40 patients with suspected sinus problems, referred to the diagnostic radiology clinic for low-dose computed tomography (CT), which was used as the reference technique. The data obtained with the new laser-based method correlated well with the grading of opacification and ventilation using CT. The sensitivity and specificity were estimated to be 93% and 61%, respectively, for the maxillary sinuses, and 94% and 86%, respectively, for the frontal sinuses. Good reproducibility was shown. The laser-based technique presents real-time clinical data that correlate well to CT findings, while being non-intrusive and avoiding the use of ionizing radiation.

  16. CT number of the fatty liver

    International Nuclear Information System (INIS)

    Maeda, Hiroko; Kawai, Takeshi; Kanasaki, Yoshiki; Akagi, Hiroaki

    1981-01-01

    This report is studied on CT number and CT images of the eight cases with fatty liver. Five of these cases showed the reversal of densities of the liver and vessels. In these cases, the diagnoses of the fatty liver were easible. In other cases, the diagnoses were possible only by comparison of the CT number of the liver and spleen because the CT number of normal liver were higher than those of the spleen. In the results which we examined the correlation of the CT number and specific gravities of the blood, normal saline, distilled water, mayonnaise, eatable iol, ethyl alcohol and lard, we observed the linear relationship between CT number and specific gravities. And so, we think that the diagnosis of the fatty liver and the degree of fatty infiltration can be guessed by the CT number of the liver and spleen. (author)

  17. CT of Mirizzi syndrome

    International Nuclear Information System (INIS)

    Yamamoto, Shinichiro; Fukushima, Keisuke; Ishihara, Kenji; Hirano, Yutaka; Sano, Kaizo

    1983-01-01

    PTC or ERCP findings of four cases of Mirizzi syndrome were demonstrated. They consisted of a smooth stricture of the common hepatic duct, curved impressions of the duct and dilatation of proximal biliary radicles. CT could visualize the impacted stone in the neck of the gallbladder, dilatation of proximal common hepatic and intrahepatic duct. Absence of the dilatation of distal common bile duct could also be confirmed by CT, thus the diagnosis of Mirizzi syndrome might be possible by CT. (author)

  18. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... multislice CT" or "multidetector CT," allow thinner slices to be obtained, resulting in more detail of the body, in a shorter period of time. Modern CT scanners are so fast that they can scan through large sections of the body in just a few seconds. Such speed is beneficial for ...

  19. Normal CT anatomy of the spine

    International Nuclear Information System (INIS)

    Quiroga, O.; Matozzi, F.; Beranger, M.; Nazarian, S.; Salamon, G.; Gambarelli, J.

    1982-01-01

    To analyse the anatomo-radiological correlation of the spine and spinal cord, 22 formalized, frozen anatomical specimens corresponding to different regions of the spinal column (8 cervical, 5 dorsal, and 9 lumbar) were studied by CT scans on axial, sagittal and coronal planes and by contact radiography after they were cut into anatomical slices in order to clarify the normal CT anatomy of the spinal column. The results obtained from CT patient scans, performed exclusively on the axial plane, were compared with those obtained from the anatomical specimens (both CT and contrast radiography). High resolution CT programs were used, enabling us to obtain better individualization of the normal structures contained in the spinal column. Direct sagittal and coronal sections were performed on the specimens in order to get further anatomo-radiological information. Enhanced CT studies of the specimens were also available because of the air already present in the subarachnoid spaces. Excellent visualization was obtained of bone structures, soft tissue and the spinal cord. High CT resolution of the spine appeares to be an excellent neuroradiological procedure to study the spine and spinal cord. A metrizamide CT scan is, however, necessary when a normal unenhanced CT scan is insufficient for diagnosis and when the spinal cord is not clearly visible, as often happens at the cervical level. Clinical findings are certainly very useful to ascertain the exact CT level and to limit the radiation exposure. (orig.)

  20. Life-cycle comparison of greenhouse gas emissions and water consumption for coal and shale gas fired power generation in China

    International Nuclear Information System (INIS)

    Chang, Yuan; Huang, Runze; Ries, Robert J.; Masanet, Eric

    2015-01-01

    China has the world's largest shale gas reserves, which might enable it to pursue a new pathway for electricity generation. This study employed hybrid LCI (life cycle inventory) models to quantify the ETW (extraction-to-wire) GHG (greenhouse gas) emissions and water consumption per kWh of coal- and shale gas-fired electricity in China. Results suggest that a coal-to-shale gas shift and upgrading coal-fired power generation technologies could provide pathways to less GHG and water intensive power in China. Compared to different coal-fired generation technologies, the ETW GHG emissions intensity of gas-fired CC (combined cycle) technology is 530 g CO 2 e/kWh, which is 38–45% less than China's present coal-fired electricity. Gas-fired CT (combustion turbine) technology has the lowest ETW water consumption intensity at 960 g/kWh, which is 34–60% lower than China's present coal-fired electricity. The GHG-water tradeoff of the two gas-fired power generation technologies suggests that gas-fired power generation technologies should be selected based on regional-specific water resource availabilities and electricity demand fluctuations in China. However, the low price of coal-fired electricity, high cost of shale gas production, insufficient pipeline infrastructures, and multiple consumers of shale gas resources may serve as barriers to a coal-to-shale gas shift in China's power sector in the near term. - Highlights: • The GHG and water footprints of coal- and shale gas-fired electricity are estimated. • A coal-to-shale gas shift can enable less GHG and water intensive power in China. • The GHG emissions of shale gas-fired combined cycle technology is 530 g CO 2 e/kWh. • The water consumption of shale gas-fired combustion turbine technology is 960 g/kWh. • Shale gas-fired power generation technologies selection should be regional-specific

  1. Diagnosis of gastric cancers by CT

    International Nuclear Information System (INIS)

    Zhu Jianbing; Gong Jianping; Huan Jian

    1999-01-01

    Forty two cases of gastric cancers were reviewed. The cancer had been examined by CT and was confirmed by operation and pathology. The diagnostic results of gastric cancers obtained by CT were compared with that from GI and fibro-gastroscopy examination. The results showed that the preparation of gastrointestinal tract before CT examination was important in the CT diagnosis of gastric cancer. CT in diagnosis of focus of gastric cancer and organ invasion is better than Gl and Fibro-gastroscopy and accuracy in diagnosis of gastric cancers is near to that of GI examination

  2. Effective radiation dose from semicoronal CT of the sacroiliac joints in comparison with axial CT and conventional radiography

    Energy Technology Data Exchange (ETDEWEB)

    Jurik, Anne Grethe; Boecker Puhakka, Katriina [Department of Radiology R, Aarhus University Hospital, Aarhus Kommunehospital, Noerrebrogade 44, 8000 Aarhus C (Denmark); Hansen, Jolanta [Department of Medical Physics, Aarhus University Hospital, Aarhus Kommunehospital, Noerrebrogade 44, 8000 Aarhus C (Denmark)

    2002-11-01

    The aim of this study was to evaluate the radiation dose given by semicoronal CT of the sacroiliac joints (SIJs) in comparison with axial CT and conventional radiography. The total effective radiation doses given by serial contiguous semicoronal and axial CT, using 5-mm slices, 120 kV and 330 mAs, were determined by measurement of organ doses using an anthropomorphic Rando Alderson phantom paced with thermoluminescence dosimeters. The doses given by conventional antero-posterior (AP) and oblique projections of the SIJs were determined similarly. In a female the total effective dose by semicoronal CT was found to be more than six times lower than by axial CT and 2.5 times lower than the dose use to obtain a conventional AP radiograph, the values being 102, 678, and 255 {mu}Sv, respectively. The effective dose by semicoronal CT was only a little higher than the dose given to obtain two oblique radiographs. In a male with lead protection of the gonads the dose by semicoronal CT was four times lower than by axial CT, but higher than by conventional radiography. In conclusion, the effective dose by semicoronal CT of the SIJs is lower than by axial CT, and in females a semicoronal CT implies a lower effective radiation dose that used to obtain an AP radiograph. (orig.)

  3. Pulmonary langerhans cell histiocytosis in adults: high-resolution CT - pathology comparisons and evolutional changes at CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyo Jin; Lee, Ho Yun; Kim, Tae Sung [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Lee, Kyung Soo [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Samsung Medical Center, Department of Radiology, Seoul (Korea, Republic of); Johkoh, Takeshi [Kinki Central Hospital of Mutual Aid Association of Public School Teachers, Department of Radiology, Hyoko (Japan); Tomiyama, Noriyuki [Osaka University Graduate School of Medicine, Department of Radiology, Osaka (Japan); Han, Joungho [Sungkyunkwan University School of Medicine, Department of Pathology, Samsung Medical Center, Seoul (Korea, Republic of)

    2011-07-15

    To compare high-resolution (HR) CT and histopathological findings and to evaluate serial CT findings in pulmonary Langerhans cell histiocytosis (PLCH). We reviewed CT of lung lesions in 27 adults (M:F = 20:7, mean age, 41 {+-} 12.3 years) with PLCH. After evaluating lung abnormalities including nodules, micronodules, thick-walled, thin-walled, and bizarre-shaped cysts and reticulation, observers compared CT findings obtained at lung biopsy sites with histopathological findings. The final CT was compared with the initial CT to determine disease extent changes. The most frequently observed patterns of lung abnormalities were micronodules (n = 24, 89%), thick-walled (n = 22, 82%), and thin-walled (n = 22, 82%) cysts. Even thin-walled and bizarre cysts harboured active inflammatory Langerhans cell sheets and eosinophils in their walls. In thin-walled cysts, we noted pericystic inflammatory cell infiltrations along the alveolar walls, as well as pericystic emphysema. Thin-walled or bizarre cysts demonstrated a tendency to coalesce with surrounding cysts via their cystic wall destruction. Fourteen (52%) patients showed improvement and nine (33%) showed progressing disease. More than half of patients with pulmonary PLCH show improvement at follow-up CT. Even thin-walled cysts harbour active inflammatory cells on histopathology and exhibit improvement at follow-up CT. (orig.)

  4. CT in normal pressure hydrocephalus

    International Nuclear Information System (INIS)

    Fujita, Katsuzo; Nogaki, Hidekazu; Noda, Masaya; Kusunoki, Tadaki; Tamaki, Norihiko

    1981-01-01

    CT scans were obtained on 33 patients (age 73y. to 31y.) with the diagnosis of normal pressure hydrocephalus. In each case, the diagnosis was made on the basis of the symptoms, CT and cisternographic findings. Underlying diseases of normal pressure hydrocephalus are ruptured aneurysms (21 cases), arteriovenous malformations (2 cases), head trauma (1 case), cerebrovascular accidents (1 case) and idiopathie (8 cases). Sixteen of 33 patients showed marked improvement, five, moderate or minimal improvement, and twelve, no change. The results were compared with CT findings and clinical response to shunting. CT findings were classified into five types, bases on the degree of periventricular hypodensity (P.V.H.), the extent of brain damage by underlying diseases, and the degree of cortical atrophy. In 17 cases of type (I), CT shows the presence of P.V.H. with or without minimal frontal lobe damage and no cortical atrophy. The good surgical improvements were achieved in all cases of type (I) by shunting. In 4 cases of type (II), CT shows the presence of P.V.H. and severe brain damage without cortical atrophy. The fair clinical improvements were achieved in 2 cases (50%) by shunting. In one case of type (III), CT shows the absence of P.V.H. without brain damage nor cortical atrophy. No clinical improvement was obtained by shunting in this type. In 9 cases of type (IV) with mild cortical atrophy, the fair clinical improvement was achieved in two cases (22%) and no improvement in 7 cases. In 2 cases of type (V) with moderate or marked cortical atrophy, no clinical improvement was obtained by shunting. In conclusion, it appeared from the present study that there was a good correlation between the result of shunting and the type of CT, and clinical response to shunting operation might be predicted by classification of CT findings. (author)

  5. CT manifestation of peritoneal metastasis

    International Nuclear Information System (INIS)

    Cha, Soon Joo; Kang, Eun Young; Suh, Won Hyuck

    1989-01-01

    Peritoneal metastasis is frequent mode of dissemination of intraabdominal malignancies. Radiologic diagnosis of peritoneal metastasis has relied on indirect evidence on a barium UGI series and small bowel examination. With the advent of CT scanning, CT is capable of direct imaging of peritoneum. The sensitivity of CT in detecting peritoneal metastasis and CT manifestation of peritoneal metastatic lesions had reported occasionally, but rarely in Korea. So, authors illustrated the CT manifestation of peritoneal metastatic lesions in 32 cases of macroscopically proven cases in laparoscopy or laparotomy in Korea University Hae Wha Hospital during recent 4 years. The results are as follows. 1. Of total 32 cases, 18 cases were male and 14 cases were female. Age incidence was the most common in 6th decade. 2. The most common type of malignancy that cause peritoneal metastasis was the stomach cancer and next common type of malignancies were pancreas cancer in men and ovarian cancer in women. 3. Of total 32 cases of peritoneal metastasis which was confirmed by laparoscopy or laparotomy macroscopically, 23 cases (72%) were detected peritoneal thickening and/or omental pathology by CT, and the remaining 9 cases (28%) were not detected by CT. 4. Ascites was present in 19 cases (59%). 5. Parietal peritoneal thickening was present in 16 cases (50%) by CT and sheetlike pattern was the most common findings. The patterns of peritoneal thickening was relatively nonspecific and was not correlated with primary tumor type. 6. Tumor involvement of greater omentum by CT was present in 19 cases (59%). There were 7 cases of smudged appearance pattern, 6 cases of nodular pattern, 6 cases of omental cake pattern and no cystic mass pattern. The patterns of omental pathology was relatively nonspecific and was nor correlated with primary tumor type

  6. Helical CT defecography

    International Nuclear Information System (INIS)

    Ferrando, R.; Fiorini, G.; Beghello, A.; Cicio, G.R.; Derchi, L.E.; Consigliere, M.; Resasco, M.; Tornago, S.

    1999-01-01

    The purpose of this work is to investigate the possible role of Helical CT defecography in pelvic floor disorders by comparing the results of the investigations with those of conventional defecography. The series analyzed consisted of 90 patients, namely 62 women and 28 men, ranging in age 24-82 years. They were all submitted to conventional defecography, and 18 questionable cases were also studied with Helical CT defecography. The conventional examination was performed during the 4 standard phases of resting, squeezing, Valsalva and straining; it is used a remote-control unit. The parameters for Helical CT defecography were: 5 mm beam collimation, pitch 2, 120 KV, 250 m As and 18-20 degrees gantry inclination to acquire coronal images of the pelvic floor. The rectal ampulla was distended with a bolus of 300 mL nonionic iodinated contrast agent (dilution: 3g/cc). The patient wore a napkin and was seated on the table, except for those who could not hold the position and were thus examined supine. Twenty-second helical scans were performed at rest and during evacuation; multiplanar reconstructions were obtained especially on the sagittal plane for comparison with conventional defecographic images. Coronal Helical CT defecography images permitted to map the perineal floor muscles, while sagittal reconstructions provided information on the ampulla and the levator ani. To conclude, Helical CT defecography performed well in study of pelvic floor disorders and can follow conventional defecography especially in questionable cases [it

  7. Helical CT imaging of clinically suspected appendicitis: Correlation of CT and histological findings

    International Nuclear Information System (INIS)

    Wong, S.K.; Chan, L.P.; Yeo, A.

    2002-01-01

    PURPOSE: The diagnosis of appendicitis is traditionally made on the basis of clinical findings supported by laboratory results. The aim of our study was to determine the accuracy and feasibility of using a relatively new technique of computed tomography (CT) using only colonic contrast medium. MATERIALS AND METHODS: A total of 50 patients clinically diagnosed as having appendicitis were prospectively examined before surgery with thin-collimation helical CT from the L3 level to the acetabular roof with only rectally administered colon contrast medium. The hard copy CT images were reviewed jointly by two radiologists and a consensus was reached for each patient. The results were then compared with the surgical and histological findings at appendicectomy. RESULTS: There were 35 true-positives, one false-positive, 12 true-negatives and two false-negatives for CT. This yielded an accuracy of 94%, sensitivity of 95%, specificity of 92%, positive predictive value of 97% and negative predictive value of 86%. The appendix was identified in 45 patients (90%) and obscured by an inflammatory mass in the remaining five. An alternative diagnosis was found in 10 of 12 normal CT examinations (83%). CONCLUSION: Helical CT with rectal contrast medium is a quick, well tolerated and accurate test to diagnose appendicitis. It can offer alternative, possibly non-surgical diagnosis in patients who would otherwise have undergone laparotomy. Wong, S.K. et al. (2002)

  8. CT and MRT in mediastinal and hilar masses. CT und MRT bei mediastinalen und hilaeren Raumforderungen

    Energy Technology Data Exchange (ETDEWEB)

    Prayer, L.; Kramer, J.; Stiglbauer, R.; Wimberger, D.; Imhof, H. (Vienna Univ. (Austria). Klinik fuer Radiodiagnostik Ludwig-Boltzmann-Institut fuer Radiologisch-Physikalische Tumordiagnostik, Vienna (Austria)); Metz, V. (Vienna Univ. (Austria). 2. Chirurgische Klinik)

    1990-11-01

    Thirty-eight patients with mediastinal and/or hilar masses were imaged by computed tomography (CT) and magnetic resonance imaging (MRI). Results were analyzed retrospectively regarding the ability to demonstrate the masses, their number, size, definition, location and tissue characteristics. CT and MRI showed equivalent results in 32 cases; additional information was obtained in two patients by CT, in four patients by MRI. In view of the specific advantages and limitations of both CT and MRI we believed that in patients with mediastinal and/or hilar masses, contrast enhanced CT remains the procedure of choice after performing plain chest radiographs; in certain cases MRI will prove useful for further evaluation. (orig.).

  9. CT diagnosis of rectal cancer

    International Nuclear Information System (INIS)

    Kanda, Hiroshi; Hachisuka, Kitao; Yamaguchi, Akihiro

    1986-01-01

    Preoperative diagnosis of the depth of invasion and lymph node metastasis of rectal cancer were studied using the findings of computed tomography (CT). Of one hundred and four cases operated on for rectal cancer over a period of 32 months, thirty five cases were examined by CT with the use of olive oil enema and contrast enhancement using a 60 % Conray drip infusion with reference to the histological findings. For direct invasion into the wall, the diagnoses by CT were coincident with microscopic findings in 75 % of cancers of the rectosigmoid, in 75 % of the upper rectum and in 84 % of the lower rectum. Of all cases, 28 (80 %) were diagnosed correctly. As to local lymph node metastasis, 74 % of all diagnoses by CT corresponded with the histological diagnosis. Moreover, seventeen cases were evaluated for lateral lymph node metastasis, and the diagnostic accuracy by CT was 88 %. In conclusion, preoperative CT evaluation of the extension into the rectal wall and lymph node metastasis in rectal cancer was considesed useful. (author)

  10. CT features of appendiceal mucocele

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Won Jong; Byun, Jae Young; Jung, Jung Im; Lee, Hae Gyu; Park, Young Ha; Shin, Kyung Sub [Catholic University Medical College, Seoul (Korea, Republic of)

    1995-10-15

    To evaluate the usefulness of CT features of appendiceal mucocele in the diagnosis and evaluation of complications. We retrospectively reviewed CT findings and compared with operative findings in 7 cases of pathologically proven appendiceal mucocele. CT findings such as location and extent of the lesion, tissue density, thickness or calcification of the wall, presence of adjacent inflammatory infiltration, and visualization of normal vermiform appendix were analyzed. Appendiceal mucocele was found as homogeneous low density cystic mass adjacent to the cecum, which has no surrounding inflammatory infiltration except in one case of perforation and one case of intussusception. Mean CT number measured in 4 cases was 21 Hounsfield unit. Thin curvilinear calcifications were noted along the cystic wall in 2 cases. Normal vermiform appendix couldn't be demonstrated in all cases. Appendiceal mucocele is characterized by homogeneously low density and thin walled cystic tumor adjacent to cecum without surrounding inflammatory infiltration, and absence of normal vermiform appendix on CT. Therefore, CT is valuable in preventing operative complications of appendiceal mucocele.

  11. PET/CT. Dose-escalated image fusion?

    International Nuclear Information System (INIS)

    Brix, G.; Beyer, T.

    2005-01-01

    Clinical studies demonstrate a gain in diagnostic accuracy by employing combined PET/CT instead of separate CT and PET imaging. However, whole-body PET/CT examinations result in a comparatively high radiation burden to patients and thus require a proper justification and optimization to avoid repeated exposure or over-exposure of patients. This review article summarizes relevant data concerning radiation exposure of patients resulting from the different components of a combined PET/CT examination and presents different imaging strategies that can help to balance the diagnostic needs and the radiation protection requirements. In addition various dose reduction measures are discussed, some of which can be adopted from CT practice, while others mandate modifications to the existing hard- and software of PET/CT systems. (orig.)

  12. Optical-CT scanning of polymer gels

    Energy Technology Data Exchange (ETDEWEB)

    Oldham, M [Radiation Oncology Physics, Duke University Medical Center, Duke University, NC (United States)

    2004-01-01

    The application of optical-CT scanning to achieve accurate high-resolution 3D dosimetry is a subject of current interest. The purpose of this paper is to provide a brief overview of past research and achievements in optical-CT polymer gel dosimetry, and to review current issues and challenges. The origins of optical-CT imaging of light-scattering polymer gels are reviewed. Techniques to characterize and optimize optical-CT performance are presented. Particular attention is given to studies of artifacts in optical-CT imaging, an important area that has not been well studied to date. The technique of optical-CT simulation by Monte-Carlo modeling is introduced as a tool to explore such artifacts. New simulation studies are presented and compared with experimental data.

  13. Optical-CT scanning of polymer gels

    International Nuclear Information System (INIS)

    Oldham, M

    2004-01-01

    The application of optical-CT scanning to achieve accurate high-resolution 3D dosimetry is a subject of current interest. The purpose of this paper is to provide a brief overview of past research and achievements in optical-CT polymer gel dosimetry, and to review current issues and challenges. The origins of optical-CT imaging of light-scattering polymer gels are reviewed. Techniques to characterize and optimize optical-CT performance are presented. Particular attention is given to studies of artifacts in optical-CT imaging, an important area that has not been well studied to date. The technique of optical-CT simulation by Monte-Carlo modeling is introduced as a tool to explore such artifacts. New simulation studies are presented and compared with experimental data

  14. Three-dimensional-CT imaging of colorectal disease with thin collimation helical CT scanning

    International Nuclear Information System (INIS)

    Ogura, Toshihiro; Koizumi, Koichi; Sakai, Tatsuya; Kai, Shunkichi; Takatsu, Kazuaki; Maruyama, Masakazu

    1998-01-01

    We have conducted research on three-dimensional (3D)-CT-colonoscopy with thin collimation helical CT scanning over the past three years. This has lately become a subject of special interest. 3D-CT-colonoscopy has three kinds of visualizing methods depending on the threshold setting of CT values. The first one is the virtual endoscopy method which is displayed in a similar fashion to colonoscopic images. The second one is the air image method using the air in the digestive tract as a contrast medium. The third one is the pseudo-tract method which has characteristics of both virtual endoscopy and the air image method and visualizes in a shape of the digestive tract. The image visualized by 3D-CT-colonoscopy is similar to that of conventional colonoscopy and barium enema study, which is obtained with minimal invasion to patients. Obvious advanced carcinomas were easily visualized, and even a small flat polyp measuring 5 mm in size, was able to be observed retrospectively. The characteristics of our method are that we can easily make an examination in a short time and with little dependence on expert technique. Also patients have little discomfort compared to that experienced during colonoscopy and barium enema study. Important features are as follows; long calculation time, insufficient air insufflation, fecal material in the patient''s bowel, whole abdominal scan, and spatial resolution. In the near future, a multislice CT scanner system will have ability to overcome these problems. Therefore, 3D-CT-colonoscopy might be applied in the future for first line examination as a mass screening for colorectal carcinoma. (author)

  15. Developmental venous anomalies: appearance on whole-brain CT digital subtraction angiography and CT perfusion

    International Nuclear Information System (INIS)

    Hanson, Eric H.; Roach, Cayce J.; Ringdahl, Erik N.; Wynn, Brad L.; DeChancie, Sean M.; Mann, Nathan D.; Diamond, Alan S.; Orrison, William W.

    2011-01-01

    Developmental venous anomalies (DVA) consist of dilated intramedullary veins that converge into a large collecting vein. The appearance of these anomalies was evaluated on whole-brain computed tomography (CT) digital subtraction angiography (DSA) and CT perfusion (CTP) studies. CT data sets of ten anonymized patients were retrospectively analyzed. Five patients had evidence of DVA and five age- and sex-matched controls were without known neurovascular abnormalities. CT angiograms, CT arterial-venous views, 4-D CT DSA and CTP maps were acquired on a dynamic volume imaging protocol on a 320-detector row CT scanner. Whole-brain CTP parameters were evaluated for cerebral blood flow (CBF), cerebral blood volume (CBV), time to peak (TTP), mean transit time (MTT), and delay. DSA was utilized to visualize DVA anatomy. Radiation dose was recorded from the scanner console. Increased CTP values were present in the DVA relative to the unaffected contralateral hemisphere of 48%, 32%, and 26%; and for the control group with matched hemispheric comparisons of 2%, -10%, and 9% for CBF, CBV, and MTT, respectively. Average effective radiation dose was 4.4 mSv. Whole-brain DSA and CTP imaging can demonstrate a characteristic appearance of altered DVA hemodynamic parameters and capture the anomalies in superior cortices of the cerebrum and the cerebellum. Future research may identify the rare subsets of patients at increased risk of adverse outcomes secondary to the altered hemodynamics to facilitate tailored imaging surveillance and application of appropriate preventive therapeutic measures. (orig.)

  16. Developmental venous anomalies: appearance on whole-brain CT digital subtraction angiography and CT perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Hanson, Eric H. [Advanced Medical Imaging and Genetics (Amigenics), Las Vegas, NV (United States); Touro University Nevada College of Osteopathic Medicine, Henderson, NV (United States); University of Nevada Las Vegas, Department of Health Physics and Diagnostic Sciences, 4505 Maryland Parkway, Box 453037, Las Vegas, NV (United States); Amigenics, Inc, Las Vegas, NV (United States); Roach, Cayce J. [Advanced Medical Imaging and Genetics (Amigenics), Las Vegas, NV (United States); University of Nevada Las Vegas, School of Life Sciences, Las Vegas, NV (United States); Ringdahl, Erik N. [University of Nevada Las Vegas, Department of Psychology, Las Vegas, NV (United States); Wynn, Brad L. [Family Medicine Spokane, Spokane, WA (United States); DeChancie, Sean M.; Mann, Nathan D. [Touro University Nevada College of Osteopathic Medicine, Henderson, NV (United States); Diamond, Alan S. [CHW Nevada Imaging Company, Nevada Imaging Centers, Spring Valley, Las Vegas, NV (United States); Orrison, William W. [Touro University Nevada College of Osteopathic Medicine, Henderson, NV (United States); University of Nevada Las Vegas, Department of Health Physics and Diagnostic Sciences, 4505 Maryland Parkway, Box 453037, Las Vegas, NV (United States); CHW Nevada Imaging Company, Nevada Imaging Centers, Spring Valley, Las Vegas, NV (United States); University of Nevada School of Medicine, Department of Medical Education, Reno, NV (United States)

    2011-05-15

    Developmental venous anomalies (DVA) consist of dilated intramedullary veins that converge into a large collecting vein. The appearance of these anomalies was evaluated on whole-brain computed tomography (CT) digital subtraction angiography (DSA) and CT perfusion (CTP) studies. CT data sets of ten anonymized patients were retrospectively analyzed. Five patients had evidence of DVA and five age- and sex-matched controls were without known neurovascular abnormalities. CT angiograms, CT arterial-venous views, 4-D CT DSA and CTP maps were acquired on a dynamic volume imaging protocol on a 320-detector row CT scanner. Whole-brain CTP parameters were evaluated for cerebral blood flow (CBF), cerebral blood volume (CBV), time to peak (TTP), mean transit time (MTT), and delay. DSA was utilized to visualize DVA anatomy. Radiation dose was recorded from the scanner console. Increased CTP values were present in the DVA relative to the unaffected contralateral hemisphere of 48%, 32%, and 26%; and for the control group with matched hemispheric comparisons of 2%, -10%, and 9% for CBF, CBV, and MTT, respectively. Average effective radiation dose was 4.4 mSv. Whole-brain DSA and CTP imaging can demonstrate a characteristic appearance of altered DVA hemodynamic parameters and capture the anomalies in superior cortices of the cerebrum and the cerebellum. Future research may identify the rare subsets of patients at increased risk of adverse outcomes secondary to the altered hemodynamics to facilitate tailored imaging surveillance and application of appropriate preventive therapeutic measures. (orig.)

  17. Development of ''Eminence STARGATE'' PET/CT system

    International Nuclear Information System (INIS)

    Okazaki, Masato; Inoue, Yoshihiro; Amano, Masaharu

    2009-01-01

    A PET/CT system, the combination of a PET (Positron Emission Tomography) system with an X-ray CT system, has been widely used in recent years. Our newly developed ''Eminence STARGATE'' PET/CT system allows the PET gantry and the X-ray CT gantry to move independently. This advantage provides high flexibility for PET examination and X-ray CT examination and also eases a patient's psychological anxiety about closed spaces. The system has a 16-slice X-ray CT scanner. (author)

  18. CT findings in epileptic children

    International Nuclear Information System (INIS)

    Koide, Nobuo; Kimura, Shigeru; Watanabe, Jun; Haneda, Satoshi; Takebe, Yukinao

    1981-01-01

    CT findings in 43 children with generalized seizures (grand mal seizures) (GM group) and in 50 children with partial seizures (P group), classified according to clinical seizure type, were studied. 1) CT abnormalities were demonstrated in 19% (8/43) in GM group and in 40% (20/50) in P group, including localized CT abnormalities in 9.3% (4/43) and in 34% (17/50) respectively. CT abnormalities were found more frequently in cases with abnormal past histories and/or mental defects (MD) than in those without them. 2) In P group, localized CT abnormalities and generalized brain atrophy were observed in 13 and 7 cases respectively. In 40 cases with focal epileptic discharges (FED) in EEG, localized CT abnormalities were demonstrated in 23% (9/40). The sites of localized CT abnormalities corresponded in 73% (11/15) to the sites of focal suppression in EEG (i.e., slowing, low amplitude and lazy pattern) regardless of FED. 3) The bicaudate cerebro-ventricular index (B-CVI) in 19 cases in the normal control group over 2 years of age was 10.0 +- 1.2 (mean +- SD). Ventricular narrowing (VN), with B-CVI less than 8.2 (mean - 1.5 SD), was observed in 5, 17 and 27% in control, GM and P groups respectively, indicating more frequently in epileptic children than in normal controls. Seizures were well controlled in 85% (11/13) in VN group and in 70% (26/36) in normal ventricular group. Brain atrophy in CT findings to inspection was ascertained in all cases by measuring B-CVI. (author)

  19. The diagnostic utility of ultrasonography, CT and PET/CT for the preoperative evaluation of cervical lymph node metastasis inpapillary thyroid cancer patients

    International Nuclear Information System (INIS)

    Kim Young Sang; Lee, Tae Hyun; Park, Dong Hee

    2016-01-01

    To compare the diagnostic utility of ultrasonography (US), CT and positron emission tomography/CT (PET/CT) in the preoperative evaluation of cervical lymph node metastasis in patients with papillary thyroid carcinoma. The study population consisted of 300 patients with pathologically diagnosed papillary thyroid carcinoma after thyroidectomy and neck dissection. Preoperative US, CT, and PET/CT findings were compared with pathologic outcomes after thyroidectomy and neck dissection. Sensitivity in detecting central lymph node metastasis (US 29.9%, CT 27.9%, PET/CT 18.8%) was lower than that for lateral lymph node metastasis (US 56.3%, CT 66.2%, PET/CT 43.7%). Specificity in detecting central lymph node metastasis (US 80.6%, CT 77.7%, PET/CT 83.0%) was lower than that for lateral lymph node metastasis (US 96.8%, CT 80.6%, PET/CT 95.2%). The combination of US and CT had higher specificity (77.3%) and higher sensitivity (33.1%) than US alone. PET/CT has no significant additional benefit over the combination of US and CT. In preoperative evaluations of neck lymph node metastasis, US and CT and PET/CT are more useful in lateral lymph node areas than in central lymph node areas. The combination of US and CT has higher sensitivity than US alone

  20. The diagnostic utility of ultrasonography, CT and PET/CT for the preoperative evaluation of cervical lymph node metastasis inpapillary thyroid cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim Young Sang; Lee, Tae Hyun; Park, Dong Hee [Dept. of Radiology, Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    2016-08-15

    To compare the diagnostic utility of ultrasonography (US), CT and positron emission tomography/CT (PET/CT) in the preoperative evaluation of cervical lymph node metastasis in patients with papillary thyroid carcinoma. The study population consisted of 300 patients with pathologically diagnosed papillary thyroid carcinoma after thyroidectomy and neck dissection. Preoperative US, CT, and PET/CT findings were compared with pathologic outcomes after thyroidectomy and neck dissection. Sensitivity in detecting central lymph node metastasis (US 29.9%, CT 27.9%, PET/CT 18.8%) was lower than that for lateral lymph node metastasis (US 56.3%, CT 66.2%, PET/CT 43.7%). Specificity in detecting central lymph node metastasis (US 80.6%, CT 77.7%, PET/CT 83.0%) was lower than that for lateral lymph node metastasis (US 96.8%, CT 80.6%, PET/CT 95.2%). The combination of US and CT had higher specificity (77.3%) and higher sensitivity (33.1%) than US alone. PET/CT has no significant additional benefit over the combination of US and CT. In preoperative evaluations of neck lymph node metastasis, US and CT and PET/CT are more useful in lateral lymph node areas than in central lymph node areas. The combination of US and CT has higher sensitivity than US alone.

  1. Automated size-specific CT dose monitoring program: Assessing variability in CT dose

    Energy Technology Data Exchange (ETDEWEB)

    Christianson, Olav; Li Xiang; Frush, Donald; Samei, Ehsan [Clinical Imaging Physics Group, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 and Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Clinical Imaging Physics Group, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States) and Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Clinical Imaging Physics Group, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Department of Physics, Duke University, Durham, North Carolina 27710 (United States); and Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708 (United States)

    2012-11-15

    Purpose: The potential health risks associated with low levels of ionizing radiation have created a movement in the radiology community to optimize computed tomography (CT) imaging protocols to use the lowest radiation dose possible without compromising the diagnostic usefulness of the images. Despite efforts to use appropriate and consistent radiation doses, studies suggest that a great deal of variability in radiation dose exists both within and between institutions for CT imaging. In this context, the authors have developed an automated size-specific radiation dose monitoring program for CT and used this program to assess variability in size-adjusted effective dose from CT imaging. Methods: The authors radiation dose monitoring program operates on an independent health insurance portability and accountability act compliant dosimetry server. Digital imaging and communication in medicine routing software is used to isolate dose report screen captures and scout images for all incoming CT studies. Effective dose conversion factors (k-factors) are determined based on the protocol and optical character recognition is used to extract the CT dose index and dose-length product. The patient's thickness is obtained by applying an adaptive thresholding algorithm to the scout images and is used to calculate the size-adjusted effective dose (ED{sub adj}). The radiation dose monitoring program was used to collect data on 6351 CT studies from three scanner models (GE Lightspeed Pro 16, GE Lightspeed VCT, and GE Definition CT750 HD) and two institutions over a one-month period and to analyze the variability in ED{sub adj} between scanner models and across institutions. Results: No significant difference was found between computer measurements of patient thickness and observer measurements (p= 0.17), and the average difference between the two methods was less than 4%. Applying the size correction resulted in ED{sub adj} that differed by up to 44% from effective dose

  2. CT cystography

    International Nuclear Information System (INIS)

    Tsili, A.

    2012-01-01

    Full text: Cancer of the urinary bladder is one of the commonest urothelial neoplasms. Conventional cystoscopy remains the mainstay in the diagnosis of urinary bladder carcinomas. But it is an invasive and uncomfortable procedure, associated with complications. Computed tomographic (CT) virtual cystoscopy has been proposed as an alternative imaging modality with potential advantages in the detection of urinary bladder neoplasms and good patient acceptance. It is a minimally invasive technique, allowing imaging of the urinary bladder in multiple planes and a 360 0 view. CT cystoscopy provides information about the location, size and morphologic features of urinary bladder lesions, indicating appropriate areas for biopsy. It can be performed in cases in which conventional cystoscopy is not feasible, such as in the presence of urethral strictures, marked prostatic hypertrophy or active bleeding, and in cases in which cystoscopic findings are inconclusive. The technique can be used to evaluate areas of the urinary bladder difficult to evaluate with cystoscopy, such as the anterior bladder neck and narrowmouthed diverticula. Finally, virtual cystoscopy provides both intraluminal and extraluminal pathologic changes, so intravesical disease and exrtavesical extension can be evaluated in the same study. One of the limitations of this technique is the difficulty to demonstrate small-sized lesions. The introduction of multi-detector row CT (MDCT) scanners was a major technological advancement because among other things it substantially improves z-axis resolution by reducing section collimation and allowing the detection of very small lesions. The near isotropic or isotropic pixels achieved with a multidetector CT scanner, enable the creation of multiplanar reformatted images with a resolution very close to that of the axial images and three-dimensional (3D) renderings of outstanding quality. Transverse, multiplanar reformations and virtual endoscopic images are complementary

  3. FDG-PET/CT in oncology. German guideline

    International Nuclear Information System (INIS)

    Krause, B.J.; Beyer, T.; Bockisch, A.; Delbeke, D.; Kotzerke, J.; Minkov, V.; Reiser, M.; Willich, N.

    2007-01-01

    FDG-PET/CT examinations combine metabolic and morphologic imaging within an integrated procedure. Over the past decade PET/CT imaging has gained wide clinical acceptance in the field of oncology. This FDG-PET/CT guideline focuses on indications, data acquisition and processing as well as documentation of FDG-PET/CT examinations in oncologic patients within a clinical and social context specific to Germany. Background information and definitions are followed by examples of clinical and research applications of FDG-PET/CT. Furthermore, protocols for CT scanning (low dose and contrast-enhanced CT) and PET emission imaging are discussed. Documentation and reporting of examinations are specified. Image interpretation criteria and sources of errors are discussed. Quality control for FDG and PET/CT-systems, qualification requirements of personnel as well as legal aspects are presented. (orig.)

  4. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... of CT Scanning of the Abdomen and Pelvis? What is CT Scanning of the Abdomen/Pelvis? Computed ... soft tissues and blood vessels. top of page What are some common uses of the procedure? This ...

  5. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... CT of the Sinuses? CT is usually the first test ordered when a sinus tumor is suspected. ... Radiology (ACR) and the Radiological Society of North America (RSNA), comprising physicians with expertise in several radiologic ...

  6. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... the scanning. Any motion, whether breathing or body movements, can lead to artifacts on the images. This ... clinical problems. CT is less sensitive to patient movement than MRI. CT can be performed if you ...

  7. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... the scanning. Any motion, whether breathing or body movements, can lead to artifacts on the images. This ... clinical problems. CT is less sensitive to patient movement than MRI. CT can be performed if you ...

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the scanning. Any motion, whether breathing or body movements, can lead to artifacts on the images. This ... clinical problems. CT is less sensitive to patient movement than MRI. CT can be performed if you ...

  9. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... CT scanner or may be over the weight limit—usually 450 pounds—for the moving table. CT ... type your comment or suggestion into the following text box: Comment: E-mail: Area code: Phone no: ...

  10. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... microphone. top of page How does the procedure work? In many ways CT scanning works very much ... CT scan, an experienced radiologist can diagnose many causes of abdominal pain or injury from trauma with ...

  11. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... preferable over CT scanning. top of page Additional Information and Resources RTAnswers.org: Radiation Therapy for Bladder ...

  12. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector ... Safety page for more information about radiation dose. Women should always inform their physician and x-ray ...

  13. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector ... Safety page for more information about radiation dose. Women should always inform their physician and x-ray ...

  14. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector ... Safety page for more information about radiation dose. Women should always inform their physician and x-ray ...

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... cavities (ventricles) in patients with hydrocephalus . diseases or malformations of the skull. CT scanning is also performed ... biopsy ) from the brain. assess aneurysms or arteriovenous malformations through a technique called CT angiography. For more ...

  16. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  17. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  18. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  19. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... prescribed procedure with your doctor, the medical facility staff and/or your insurance provider to get a ...

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... prescribed procedure with your doctor, the medical facility staff and/or your insurance provider to get a ...

  1. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... prescribed procedure with your doctor, the medical facility staff and/or your insurance provider to get a ...

  2. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... benefits vs. risks? Benefits A CT scan is one of the safest means of studying the sinuses. ... CT scanning provides very detailed images of many types of tissue as well as the lungs, bones, ...

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... can be performed if you have an implanted medical device of any kind, unlike MRI. CT imaging ...

  4. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... can be performed if you have an implanted medical device of any kind, unlike MRI. CT imaging ...

  5. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... about tumors of the nasal cavity and sinuses. plan for surgery by defining anatomy. top of page ... for sinusitis. CT of the sinuses can help plan the safest and most effective surgery. CT of ...

  6. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... to a CD or DVD. CT images of internal organs, bones, soft tissue and blood vessels provide ... clicking and whirring sounds as the CT scanner's internal parts, not usually visible to you, revolve around ...

  7. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... Safety Images related to Computed Tomography (CT) - Head Videos related to Computed Tomography (CT) - Head Sponsored by ...

  8. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... related to Computed Tomography (CT) - Abdomen and Pelvis Videos related to Computed Tomography (CT) - Abdomen and Pelvis ...

  9. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... as a CT or CAT scan, is a diagnostic medical test that, like traditional x-rays, produces ... particularly the lungs, abdomen, pelvis and bones. A diagnosis determined by CT scanning may eliminate the need ...

  10. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... as a CT or CAT scan, is a diagnostic medical test that, like traditional x-rays, produces ... medical device of any kind, unlike MRI. A diagnosis determined by CT scanning may eliminate the need ...

  11. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... CT scanning. top of page Additional Information and Resources RTAnswers.org: Radiation Therapy for Bladder Cancer Radiation ... Image Gallery Patient undergoing computed tomography (CT) scan View full size with caption Pediatric Content Some imaging ...

  12. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... CT) of the abdomen and pelvis is a diagnostic imaging test used to help detect diseases of ... as a CT or CAT scan, is a diagnostic medical test that, like traditional x-rays, produces ...

  13. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... sometimes compared to looking into a loaf of bread by cutting the loaf into thin slices. When ... actual CT scanning is performed. Depending on the type of CT scan, the machine may make several ...

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... microphone. top of page How does the procedure work? In many ways CT scanning works very much ... head CT scanning. Manufacturers of intravenous contrast indicate mothers should not breastfeed their babies for 24-48 ...

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits CT scanning is painless, noninvasive and accurate. ... CT scans should have no immediate side effects. Risks There is always a slight chance of cancer ...

  16. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Viewing a CT scan, an experienced radiologist ... CT scans should have no immediate side effects. Risks There is always a slight chance of cancer ...

  17. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits A CT scan is one of the ... CT scans should have no immediate side effects. Risks There is always a slight chance of cancer ...

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... membranes covering the brain. top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Brain ...

  19. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... for the moving table. top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Head ...

  20. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... air-filled spaces within the bones of the face surrounding the nasal cavity. CT scanning is painless, ... and blood vessels. A CT scan of the face produces images that also show a patient's paranasal ...

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... Then, the table will move slowly through the machine as the actual CT scanning is performed. Depending ...

  2. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... Then, the table will move slowly through the machine as the actual CT scanning is performed. Depending ...

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... Then, the table will move slowly through the machine as the actual CT scanning is performed. Depending ...

  4. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... CT scanner is typically a large, box-like machine with a hole, or short tunnel, in the ... Then, the table will move slowly through the machine as the actual CT scanning is performed. Depending ...

  5. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... CT scanner is typically a large, box-like machine with a hole, or short tunnel, in the ... Then, the table will move slowly through the machine as the actual CT scanning is performed. Depending ...

  6. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... CT scanner is typically a large, box-like machine with a hole, or short tunnel, in the ... Then, the table will move slowly through the machine as the actual CT scanning is performed. Depending ...

  7. Imaging of female pelvic malignancies regarding MRI, CT, and PET/CT. Pt. 2

    International Nuclear Information System (INIS)

    Alt, Celine D.; Kauczor, Hans-Ulrich; Hallscheidt, Peter; Brocker, Kerstin A.; Eichbaum, Michael; Sohn, Christof; Arnegger, Florian U.

    2011-01-01

    To compose diagnostic standard operating procedures for both clinical and imaging assessment for vulvar and vaginal cancer, for vaginal sarcoma, and for ovarian cancer. The literature was reviewed for diagnosing the above mentioned malignancies in the female pelvis. Special focus herein lies in tumor representation in MRI, followed by the evaluation of CT and PET/CT for this topic. MRI is a useful additional diagnostic complement but by no means replaces established methods of gynecologic diagnostics and ultrasound. In fact, MRI is only implemented in the guidelines for vulvar cancer. According to the current literature, CT is still the cross-sectional imaging modality of choice for evaluating ovarian cancer. PET/CT appears to have advantages for staging and follow-up in sarcomas and cancers of the ovaries. (orig.)

  8. The H II galaxy Hubble diagram strongly favours Rh = ct over ΛCDM

    Science.gov (United States)

    Wei, Jun-Jie; Wu, Xue-Feng; Melia, Fulvio

    2016-12-01

    We continue to build support for the proposal to use H II galaxies (HIIGx) and giant extragalactic H II regions (GEHR) as standard candles to construct the Hubble diagram at redshifts beyond the current reach of Type Ia supernovae. Using a sample of 25 high-redshift HIIGx, 107 local HIIGx, and 24 GEHR, we confirm that the correlation between the emission-line luminosity and ionized-gas velocity dispersion is a viable luminosity indicator, and use it to test and compare the standard model ΛCDM and the Rh = ct universe by optimizing the parameters in each cosmology using a maximization of the likelihood function. For the flat ΛCDM model, the best fit is obtained with Ω _m= 0.40_{-0.09}^{+0.09}. However, statistical tools, such as the Akaike (AIC), Kullback (KIC) and Bayes (BIC) Information Criteria favour Rh = ct over the standard model with a likelihood of ≈94.8-98.8 per cent versus only ≈1.2-5.2 per cent. For wCDM (the version of ΛCDM with a dark-energy equation of state wde ≡ pde/ρde rather than wde = wΛ = -1), a statistically acceptable fit is realized with Ω _m=0.22_{-0.14}^{+0.16} and w_de= -0.51_{-0.25}^{+0.15} which, however, are not fully consistent with their concordance values. In this case, wCDM has two more free parameters than Rh = ct, and is penalized more heavily by these criteria. We find that Rh = ct is strongly favoured over wCDM with a likelihood of ≈92.9-99.6 per cent versus only 0.4-7.1 per cent. The current HIIGx sample is already large enough for the BIC to rule out ΛCDM/wCDM in favour of Rh = ct at a confidence level approaching 3σ.

  9. FDG PET/CT Is Superior to Enhanced CT in Detecting Recurrent Subcentimeter Lesions in the Abdominopelvic Cavity in Colorectal Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Hai Jeon; Kim, Yu Kyeong; Kim, Sang Eun [Seoul National Univ. Bundang Hospital, Seoul (Korea, Republic of); Lee, Jong Jin [Asan Medical Center, Univ. of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2011-06-15

    This study aims to compare the performance of contrast enhanced computed tomography (CeCT) and 18 F fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) in detecting small tumor implants and metastatic lymph nodes (LNs) in the abdominopelvic cavity in patients with colorectal cancer. We enrolled 16 patients who were clinically suspected of experiencing a recurrences (6 male, 10 female; mean age 61{+-}14 years). All subjects underwent CeCT and PET/CT, and the performance of these methods was compared with regard to detecting recurrences. The final diagnosis of a recurrence was made clinically. CeCT identified 38 lesions in 12 patients, all of which were detected by PET/CT. PET/CT found 27 additional lesions in 8 patients, comprising 9 seeding nodules (2 in the right upper quadrant of the abdomen and 7 in the pelvic cavity) and 18 LNs (2 celiac, 2 paraaortic, 2 hepatic hilar, 11 common iliac, 1 external iliac). Most additional lesions were located in the pelvic cavity (approximately 78% of seeding nodules that were detected solely by PET/CT was significantly higher compared with the CeCT and PET/CT confirmed nodules (5.5{+-}4.2 vs. 2.9{+-}2.5, p=0.03). The seeding nodules that were detected only by PET/CT were significantly smaller than the CeCT and PET/CT confirmed nodules (long axis:1.0{+-}0.3cm vs. 2.0{+-}1.1cm, p=0.001; short axis: 0.8{+-}0.3cm vs. 1.7{+-}0.9cm, p=0.001). Similarly, PET/CT only detected LNs were significantly smaller than CeCT and PET/CT identified LNs (0.7{+-}0.1cm vs. 2.3{+-}1.2cm, p<0.0001). PET/CT is superior to CeCT in detecting seeding nodules and metastatic LNs in patients with recurrent colorectal cancer. Specifically, PET/CT detects subcentimeter lesions in anatomically deformed pelvic cavities.

  10. Dynamic CT of hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Fujita, Nobuyuki; Shirato, Hiroki; Shinohara, Masahiro; Miyasaka, Kazuo; Morita, Yutaka; Irie, Goro

    1983-01-01

    We performed dynamic CT in 30 cases of hepatocellular carcinoma, and concluded as below. 1 Decting the stain in the early phase of the dynamic series, it is possible to make a diagnosis of hepatocellular carcinoma. 2 The dinamic CT is effective in a case of small hepatocellular carcinoma in which it is difficult to gain an accurate diagnosis in the routine CT study. 3 The dynamic CT is also effective in the differential diagnosis of hepatic lesions, as other hepatic lesions such as hemangioma and metastatic liver cancer show different patterns compared with hepatocellular carcinoma. (author)

  11. SPECT/CT workflow and imaging protocols

    Energy Technology Data Exchange (ETDEWEB)

    Beckers, Catherine [University Hospital of Liege, Division of Nuclear Medicine and Oncological Imaging, Department of Medical Physics, Liege (Belgium); Hustinx, Roland [University Hospital of Liege, Division of Nuclear Medicine and Oncological Imaging, Department of Medical Physics, Liege (Belgium); Domaine Universitaire du Sart Tilman, Service de Medecine Nucleaire et Imagerie Oncologique, CHU de Liege, Liege (Belgium)

    2014-05-15

    Introducing a hybrid imaging method such as single photon emission computed tomography (SPECT)/CT greatly alters the routine in the nuclear medicine department. It requires designing new workflow processes and the revision of original scheduling process and imaging protocols. In addition, the imaging protocol should be adapted for each individual patient, so that performing CT is fully justified and the CT procedure is fully tailored to address the clinical issue. Such refinements often occur before the procedure is started but may be required at some intermediate stage of the procedure. Furthermore, SPECT/CT leads in many instances to a new partnership with the radiology department. This article presents practical advice and highlights the key clinical elements which need to be considered to help understand the workflow process of SPECT/CT and optimise imaging protocols. The workflow process using SPECT/CT is complex in particular because of its bimodal character, the large spectrum of stakeholders, the multiplicity of their activities at various time points and the need for real-time decision-making. With help from analytical tools developed for quality assessment, the workflow process using SPECT/CT may be separated into related, but independent steps, each with its specific human and material resources to use as inputs or outputs. This helps identify factors that could contribute to failure in routine clinical practice. At each step of the process, practical aspects to optimise imaging procedure and protocols are developed. A decision-making algorithm for justifying each CT indication as well as the appropriateness of each CT protocol is the cornerstone of routine clinical practice using SPECT/CT. In conclusion, implementing hybrid SPECT/CT imaging requires new ways of working. It is highly rewarding from a clinical perspective, but it also proves to be a daily challenge in terms of management. (orig.)

  12. SPECT/CT workflow and imaging protocols

    International Nuclear Information System (INIS)

    Beckers, Catherine; Hustinx, Roland

    2014-01-01

    Introducing a hybrid imaging method such as single photon emission computed tomography (SPECT)/CT greatly alters the routine in the nuclear medicine department. It requires designing new workflow processes and the revision of original scheduling process and imaging protocols. In addition, the imaging protocol should be adapted for each individual patient, so that performing CT is fully justified and the CT procedure is fully tailored to address the clinical issue. Such refinements often occur before the procedure is started but may be required at some intermediate stage of the procedure. Furthermore, SPECT/CT leads in many instances to a new partnership with the radiology department. This article presents practical advice and highlights the key clinical elements which need to be considered to help understand the workflow process of SPECT/CT and optimise imaging protocols. The workflow process using SPECT/CT is complex in particular because of its bimodal character, the large spectrum of stakeholders, the multiplicity of their activities at various time points and the need for real-time decision-making. With help from analytical tools developed for quality assessment, the workflow process using SPECT/CT may be separated into related, but independent steps, each with its specific human and material resources to use as inputs or outputs. This helps identify factors that could contribute to failure in routine clinical practice. At each step of the process, practical aspects to optimise imaging procedure and protocols are developed. A decision-making algorithm for justifying each CT indication as well as the appropriateness of each CT protocol is the cornerstone of routine clinical practice using SPECT/CT. In conclusion, implementing hybrid SPECT/CT imaging requires new ways of working. It is highly rewarding from a clinical perspective, but it also proves to be a daily challenge in terms of management. (orig.)

  13. Skeletal scintigraphy and SPECT/CT in orthopedic imaging; Knochenszintigrafie und SPECT/CT bei orthopaedischen Fragestellungen

    Energy Technology Data Exchange (ETDEWEB)

    Klaeser, B.; Walter, M.; Krause, T. [Inselspital Bern (Switzerland). Universitaetsklinik fuer Nuklearmedizin

    2011-03-15

    Multi-modality imaging with SPECT-CT in orthopaedics combines the excellent sensitivity of scintigraphy with the morphological information of CT as a key for specific interpretation of findings in bone scans. The result is an imaging modality with the clear potential to prove of value even in a competitive setting dominated by MRI, and to significantly add to diagnostic imaging in orthopaedics. SPECT-CT is of great value in the diagnostic evaluation after fractures, and - in contrast to MRI - it is well suited for imaging in patients with osteosyntheses and metallic implants. In sports medicine, SPECT-CT allows for a sensitive and specific detection of osseous stress reactions before morphological changes become detectable by CT or MRI. In patients with osseous pain syndromes, actively evolving degenerative changes as a cause of pain can be identified and accurately localized. Further, particularly prospective diagnostic studies providing comparative data are needed to strengthen the position of nuclear imaging in orthopaedics and sports medicine and to help implementing SPECT/CT in diagnostic algorithms. (orig.)

  14. The stylohyoid chain: CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Uysal Ramadan, Selma, E-mail: uysalselma@yahoo.co [Department of Radiology, Ankara Training and Research Hospital, Ankara 06590 (Turkey); Goekharman, Dilek, E-mail: gokharman@ttnet.net.t [Department of Radiology, Ankara Training and Research Hospital, Ankara 06590 (Turkey); Kosar, Pinar, E-mail: pkosar@hotmail.co [Department of Radiology, Ankara Training and Research Hospital, Ankara 06590 (Turkey); Kacar, Mahmut, E-mail: mkacar1961@gamil.co [Department of Radiology, Ankara Training and Research Hospital, Ankara 06590 (Turkey); Kosar, Ugur, E-mail: ugurkosar@hotmail.co [Department of Radiology, Ankara Training and Research Hospital, Ankara 06590 (Turkey)

    2010-09-15

    We aimed in this report to discuss the embryology, anatomy, theories of ossification and symptoms, clinical presentation, and diagnosis of the stylohyoid chain (SHC) variations, together with the role of radiographs, computed tomography (CT) and three-dimensional (3D)-CT in showing these variations. Because CT/3D-CT additionally facilitates visualization of the entire SHC with different axes, it is the most valuable method for establishing the relationship between the SHC and the surrounding tissue. SHC variation can be discovered during CT performed for indications other than ossified SHC. It is important to diagnose whether or not the SHC is ossified, since one of the treatment procedures in ossified SHC is total excision. If the clinician and radiologist are aware of these variations observed in the SHC, patients with vague symptoms may be spared unnecessary investigations and may be properly diagnosed earlier.

  15. Choline-PET/CT for imaging prostate cancer; Cholin-PET/CT zur Bildgebung des Prostatakarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Krause, Bernd Joachim [Klinik- und Poliklinik fuer Nuklearmedizin, Klinikum rechts der Isar, Technische Univ. Muenchen (Germany); Treiber, U.; Schwarzenboeck, S.; Souvatzoglou, M. [Klinik fuer Urologie, Klinikum rechts der Isar, Technische Univ. Muenchen (Germany)

    2010-09-15

    PET and PET/CT using [{sup 11}C]- and [{sup 18}F]-labelled choline derivatives are increasingly being used for imaging of prostate cancer. The value of PET and PET/CT with [{sup 11}C]- and [{sup 18}F]-labelled choline derivates in biochemical recurrence of prostate cancer has been examined in many studies and demonstrates an increasing importance. Primary prostate cancer can be detected with moderate sensitivity using PET and PET/CT using [{sup 11}C]- and [{sup 18}F]-labelled choline derivatives - the differentiation between benign prostatic hyperplasia, prostatitis or high-grade intraepithelial neoplasia (HGPIN) is not always possible. At the present time [{sup 11}C]choline PET/CT is not recommended in the primary setting but may be utilized in clinically suspected prostate cancer with repeatedly negative prostate biopsies, in preparation of a focused re-biopsy. Promising results have been obtained for the use of PET and PET/CT with [{sup 11}C]- and [{sup 18}F]-labelled choline derivates in patients with biochemical recurrence. The detection rate of choline PET and PET/CT for local, regional, and distant recurrence in patients with a biochemical recurrence shows a linear correlation with PSA values at the time of imaging and reaches about 75% in patients with PSA > 3 ng/mL. At PSA values below 1 ng/mL, the recurrence can be diagnosed with choline PET/CT in approximately 1/3 of the patients. PET and PET/CT with [{sup 11}C]- and [{sup 18}F]choline derivates can be helpful for choosing a therapeutic strategy in the sense of an individualized treatment: since an early diagnosis of recurrence is crucial to the choice of optimal treatment. The localization of the site of recurrence - local recurrence, lymph node metastasis or systemic dissemination - has important influence on the therapy regimen. (orig.)

  16. Construction of a voxel model from CT images with density derived from CT numbers

    International Nuclear Information System (INIS)

    Cheng Mengyun; Zeng Qin; Cao Ruifen; Li Gui; Zheng Huaqing; Huang Shanqing; Song Gang; Wu Yican

    2010-01-01

    The voxel models representing human anatomy have been developed to calculate dose distribution in human body, while the density is the most important physical property of voxel model. Traditionally, when creating the Monte Carlo input files, the average tissue parameters recommended in ICRP report were used to assign each voxel in the existing voxel models. However, as each tissue consists of many voxels in which voxels are different in their densities, the method of assigning average tissue parameters doesn't take account of the voxel's discrepancy, and can't represent human anatomy faithfully. To represent human anatomy more faithfully, a method was implemented to assign each voxel, the density of which was derived from CT number. In order to compare with the traditional method, we have constructed two models from a same cadaver specimen date set. A CT-based pelvic voxel model called Pelvis-CT model, was constructed, the densities of which were derived from the CT numbers. A color photograph-based pelvic voxel model called Pelvis-Photo model, was also constructed, the densities of which were taken from ICRP Publication. The CT images and color photographs were obtained from the same female cadaver specimen. The Pelvis-CT and Pelvis-Photo models were ported into Monte Carlo code MCNP to calculate the conversion coefficients from kerma free-in-air to absorbed dose for external monoenergetic photon beams with energies of 0.1, 1 and 10 MeV under anterior-posterior (AP) geometries. The results were compared with those of given in ICRP74. Differences of up to 50% were observed between conversion coefficients of Pelvis-CT and Pelvis-Photo models, moreover the discrepancies decreased for the photon beams with higher energies. The overall trend of conversion coefficients of the Pelvis-CT model were agreed well with that of ICRP74 data. (author)

  17. Construction of a voxel model from CT images with density derived from CT numbers

    International Nuclear Information System (INIS)

    Cheng Mengyun; Zeng Qin; Cao Ruifen; Li Gui; Zheng Huaqing; Huang Shanqing; Song Gang; Wu Yican

    2011-01-01

    The voxel models representing human anatomy have been developed to calculate dose distribution in human body, while the density and elemental composition are the most important physical properties of voxel model. Usually, when creating the Monte Carlo input files, the average tissue densities recommended in ICRP Publication were used to assign each voxel in the existing voxel models. As each tissue consists of many voxels with different densities, the conventional method of average tissue densities failed to take account of the voxel's discrepancy, and therefore could not represent human anatomy faithfully. To represent human anatomy more faithfully, a method was implemented to assign each voxel, the densities of which were derived from CT number. In order to compare with the traditional method, we constructed two models from the cadaver specimen dataset. A CT-based pelvic voxel model called Pelvis-CT model was constructed, the densities of which were derived from the CT numbers. A color photograph-based pelvic voxel model called Pelvis-Photo model was also constructed, the densities of which were taken from ICRP Publication. The CT images and the color photographs were obtained from the same female cadaver specimen. The Pelvis-CT and Pelvis-Photo models were both ported into Monte Carlo code MCNP to calculate the conversion coefficients from kerma free-in-air to absorbed dose for external monoenergetic photon beams with energies of 0.1, 1 and 10 MeV under anterior-posterior (AP) geometry. The results were compared with those of given in ICRP Publication 74. Differences of up to 50% were observed between conversion coefficients of Pelvis-CT and Pelvis- Photo models, moreover the discrepancies decreased for the photon beams with higher energies. The overall trend of conversion coefficients of the Pelvis-CT model agreed well with that of ICRP Publication 74 data. (author)

  18. Correlative Imaging in a Patient with Cystic Thymoma: CT, MR and PET/CT Comparison

    International Nuclear Information System (INIS)

    Romeo, Valeria; Esposito, Alfredo; Maurea, Simone; Camera, Luigi; Mainenti, Pier Paolo; Palmieri, Giovannella; Buonerba, Carlo; Salvatore, Marco

    2015-01-01

    Cystic thymoma is a rare variant of thymic neoplasm characterized by almost complete cystic degeneration with mixed internal structure. We describe a case of a 60 year-old woman with a cystic thymoma studied with advanced tomographic imaging stydies. CT, MRI and PET/CT with 18 F-FDG were performed; volumetric CT and MRI images provided better anatomic evaluation for pre-operative assessment, while PET/CT was helpful for lesion characterization based on 18 F-FDG uptake. Although imaging studies are mandatory for pre-operative evaluation of cystic thymoma, final diagnosis still remains surgical. A 60-year-old woman with recent chest pain and no history of previous disease was admitted to our departement to investigate the result of a previous chest X-ray that showed bilateral mediastinal enlargement; for this purpose, enhanced chest CT scan was performed using a 64-rows scanner (Toshiba, Aquilion 64, Japan) before and after intravenous bolus administration of iodinated non ionic contrast agent; CT images demonstrated the presence of a large mediastinal mass (11×8 cm) located in the anterior mediastinum who extended from the anonymous vein to the cardio-phrenic space, compressing the left atrium and causing medium lobe atelectasis; bilateral pleural effusion was also present. In conclusion, correlative imaging plays a foundamental role for the diagnostic evaluation of patient with cystic thymoma. In particular, volumetric CT and MRI studies can provide better anatomic informations regarding internal structure and local tumor spread for pre-operative assessment. Conversely, metabolic imaging using 18 F-FDG PET/CT is helpful for lesion characterization differentiating benign from malignant lesion on the basis of intense tracer uptake. The role of PET/MRI is still under investigation. However, final diagnosis still remains surgical even though imaging studies are mandatory for pre-operative patient management

  19. CT appearance of splenosis

    Energy Technology Data Exchange (ETDEWEB)

    Mendelson, D.S.; Cohen, B.A.; Armas, R.R.

    1982-12-01

    Splenosis is an unusual complication of splenic trauma. The computed tomographic (CT) appearance of splenosis is described. One should consider this diagnosis when faced with a history of splenic trauma and multiple round or oval masses at CT.

  20. CT appearance of splenosis

    International Nuclear Information System (INIS)

    Mendelson, D.S.; Cohen, B.A.; Armas, R.R.

    1982-01-01

    Splenosis is an unusual complication of splenic trauma. The computed tomographic (CT) appearance of splenosis is described. One should consider this diagnosis when faced with a history of splenic trauma and multiple round or oval masses at CT

  1. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... sinus cavities – hollow, air-filled spaces within the bones of the face surrounding the nasal cavity. CT ... CD or DVD. CT images of internal organs, bones, soft tissue and blood vessels provide greater detail ...

  2. Analysis of death in major trauma: value of prompt post mortem computed tomography (pmCT) in comparison to office hour autopsy.

    Science.gov (United States)

    Schmitt-Sody, Markus; Kurz, Stefanie; Reiser, Maximilian; Kanz, Karl Georg; Kirchhoff, Chlodwig; Peschel, Oliver; Kirchhoff, Sonja

    2016-03-29

    To analyze diagnostic accuracy of prompt post mortem Computed Tomography (pmCT) in determining causes of death in patients who died during trauma room management and to compare the results to gold standard autopsy during office hours. Multiple injured patients who died during trauma room care were enrolled. PmCT was performed immediately followed by autopsy during office hours. PmCT and autopsy were analyzed primarily regarding pmCT ability to find causes of death and secondarily to define exact causes of death including accurate anatomic localizations. For the secondary analysis data was divided in group-I with equal results of pmCT and autopsy, group-II with autopsy providing superior results and group-III with pmCT providing superior information contributing to but not majorly causing death. Seventeen multiple trauma patients were enrolled. Since multiple trauma patients were enrolled more injuries than patients are provided. Eight patients sustained deadly head injuries (47.1%), 11 chest (64.7%), 4 skeletal system (23.5%) injuries and one patient drowned (5.8%). Primary analysis revealed in 16/17 patients (94.1%) causes of death in accordance with autopsy. Secondary analysis revealed in 9/17 cases (group-I) good agreement of autopsy and pmCT. In seven cases autopsy provided superior results (group-II) whereas in 1 case pmCT found more information (group-III). The presented work studied the diagnostic value of pmCT in defining causes of death in comparison to standard autopsy. Primary analysis revealed that in 94.1% of cases pmCT was able to define causes of death even if only indirect signs were present. Secondary analysis showed that pmCT and autopsy showed equal results regarding causes of death in 52.9%. PmCT is useful in traumatic death allowing for an immediate identification of causes of death and providing detailed information on bony lesions, brain injuries and gas formations. It is advisable to conduct pmCT especially in cases without consent to

  3. Perforated appendicitis: accuracy of CT diagnosis and correlation of CT findings with the length of hospital

    International Nuclear Information System (INIS)

    Siddiqui, H.A.; Afzal, S.

    2007-01-01

    To determine the sensitivity and specificity of CT findings in the differentiation of perforated from nonperforated appendicitis and correlate CT diagnosis with the length of hospital stay. The study included 70 patients who presented with right lower quadrant abdominal pain and underwent preoperative CT scan followed by appendectomy. Patients were divided into two groups of having perforated and nonperforated appendicitis on the basis of CT scan findings. The surgical and pathological reports combined were considered the reference standard for the diagnosis of perforated appendicitis. Various CT scan findings and average duration of hospital stay in days was compared by t-test. Twenty-six (37%) of 70 patients had perforated appendicitis. It was correctly identified on pre-operative CT scan in 18 patients. There were 18 true positive diagnoses, 43 true negative diagnoses, 1 false positive diagnosis and 8 false negative diagnoses which yielded a sensitivity of 69%, specificity of 97%, positive predictive value of 94% and negative predictive value of 84%. Mean length of hospital stay in perforated group was 6.3 days and 2.9 days in nonperforated group. Severe periappendiceal inflammation, periappendiceal and or abdominopelvic fluid and abscess were significantly associated with perforated appendicitis and with a significant longer hospital stay (p <.001). CT scan is 69% sensitive and 97% specific for the diagnosis of perforated appendicitis and constellation of CT findings can be used to select patients with perforated appendicitis for initial non-operative management. Presence of CT signs of significant appendiceal inflammation is independent predictor of longer hospital stay. (author)

  4. Unresectable colorectal liver metastases. Percutaneous ablation using CT-guided high-dose-rate brachytherapy (CT-HDBRT); Nicht resektable kolorektale Lebermetastasen. Perkutane Ablation mittels CT-gesteuerter Hochdosisbrachytherapie (CT-HDBRT)

    Energy Technology Data Exchange (ETDEWEB)

    Collettini, F.; Lutter, A.; Schnapauff, D.; Denecke, T.; Gebauer, B. [Charite, Campus Virchow-Klinikum, Berlin (Germany). Dept. of Diagnostic and Interventional Radiology; Hildebrandt, B. [Charite, Campus Virchow-Klinikum, Berlin (Germany). Dept. of Oncology; Puhl, G. [Charite, Campus Virchow-Klinikum, Berlin (Germany). Dept. of General, Visceral and Transplantation Surgery; Wust, P. [Charite, Campus Virchow-Klinikum, Berlin (Germany). Dept. of Radiation Oncology

    2014-06-15

    Purpose: To evaluate the clinical outcome of CT-guided high-dose-rate brachytherapy (CT-HDRBT) of unresectable colorectal liver metastases (CRLMs). Materials and Methods: Retrospective analysis of all consecutive patients with unresectable CRLMs treated with CT-HDRBT between January 2008 and November 2012. Treatment was performed by CT-guided catheter placement and high-dose-rate brachytherapy with an iridium-192 source. MRI follow-up was performed after 6 weeks and then every 3 months post-intervention. The primary endpoint was local tumor control (LTC); secondary endpoints included time to progression (TTP) and overall survival (OS). Results: 80 heavily pretreated patients with 179 metastases were available for MRI evaluation for a mean follow-up time of 16.9 months. The mean tumor diameter was 28.5 mm (range: 8 - 107 mm). No major complications were observed. A total of 23 (12.9%) local tumor progressions were observed. Lesions ≥ 4 cm in diameter showed significantly more local progression than smaller lesions (< 4 cm). 50 patients (62.5%) experienced systemic tumor progression. The median TTP was 6 months. 28 (43%) patients died during the follow-up period. The median OS after ablation was 18 months. Conclusion: CT-HDRBT is an effective technique for the treatment of unresectable CRLMs and warrants promising LTC rates compared to thermal ablative techniques. A combination with other local and systemic therapies should be evaluated in patients with lesions > 4 cm in diameter, in which higher progression rates are expected. (orig.)

  5. Dental CT: examination technique, radiation load and anatomy; Dental-CT: Untersuchungstechnik, Strahlenbelastung und Anatomie

    Energy Technology Data Exchange (ETDEWEB)

    Lenglinger, F.X.; Muhr, T. [AKH Wels (Austria). Inst. fuer Radiologie; Krennmair, G. [Praxis fuer Zahn-, Mund- und Kieferheilkunde und Implantologie, Marchtrenk (Austria)

    1999-12-01

    Traditionally oral surgeons and dentists have evaluated the jaws using intraoral films and panoramic radiographs. The involvement of radiologists has been limited. In the past few years dedicated CT-software-programs developed to evaluate dental implant patients have provided a new look at the jaws. The complex anatomy is described and identified on human skulls and on axial, panoramic, and cross-sectional images. With this anatomic description Dental-CT-scans are used to demonstrate the anatomy of maxilla and the mandible. An overview of the technique of Dental-CT is provided, furthermore the radiation dose of different organs is explained. Suggestions to reduce these doses by simple modifications of the recommended protocols are given. (orig.) [German] Die Einfuehrung im Bereich der Computertomographiesoftware (Dental-CT) ermoeglicht dem Radiologen zusaetzlich zu den ueblichen, von den Zahnaerzten durchgefuehrten Roentgenuntersuchungen eine ueberlagerungs- und verzerrungsfreie Darstellung des Ober- und Unterkiefers. In der Implantologie ist mit dieser Darstellung eine exakte Planung moeglich. Weiterhin haben sich Duennschicht-CT-Untersuchungen auch bei der Abklaerung von Zysten, Tumoren, Frakturen, tiefen Parodontitiden und retinierten Zaehnen bewaehrt. In dieser Zeit wird ein Ueberblick ueber die Anatomie, die Untersuchungstechnik des Dental-CT und die auftretende Strahlenbelastung gegeben. Basierend auf rezente Literaturangaben kann eine Reduktion der absorbierten Dosis bei gleichbleibender Bildqualitaet durch einfache Protokollmodifikationen erzielt werden. (orig.)

  6. Monte Carlo dose calibration in CT scanner

    International Nuclear Information System (INIS)

    Yadav, Poonam; Ramasubramanian, V.; Subbaiah, K.V.; Thayalan, K.

    2008-01-01

    Computed Tomography (CT) scanner is a high radiation imaging modality compared to radiography. The dose from a CT examination can vary greatly depending on the particular CT scanner used, the area of the body examined, and the operating parameters of the scan. CT is a major contributor to collective effective dose in diagnostic radiology. Apart from the clinical benefits, the widespread use of multislice scanner is increasing radiation level to patient in comparison with conventional CT scanner. So, it becomes necessary to increase awareness about the CT scanner. (author)

  7. {sup 18}F-FDG PET/CT imaging versus dynamic contrast-enhanced CT for staging and prognosis of inflammatory breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Champion, Laurence; Edeline, Veronique; Giraudet, Anne-Laure; Wartski, Myriam [Service de Medecine Nucleaire, Saint-Cloud (France); Lerebours, Florence [Service d' Oncologie Medicale, Saint-Cloud (France); Cherel, Pascal [Institut Curie, Hopital Rene Huguenin, Service de Radiologie, Saint-Cloud (France); Bellet, Dominique [Service de Medecine Nucleaire, Saint-Cloud (France); Universite Paris Descartes, Pharmacologie Chimique et Genetique and Imagerie, Inserm U1022 CNRS UMR 8151, Faculte des sciences pharmaceutiques et biologiques, Paris (France); Alberini, Jean-Louis [Service de Medecine Nucleaire, Saint-Cloud (France); Universite Versailles Saint-Quentin, Faculte de medecine, Saint-Quentin-en-Yvelines (France)

    2013-08-15

    Inflammatory breast cancer (IBC) is the most aggressive type of breast cancer with a poor prognosis. Locoregional staging is based on dynamic contrast-enhanced (DCE) CT or MRI. The aim of this study was to compare the performances of FDG PET/CT and DCE CT in locoregional staging of IBC and to assess their respective prognostic values. The study group comprised 50 women (median age: 51 {+-} 11 years) followed in our institution for IBC who underwent FDG PET/CT and DCE CT scans (median interval 5 {+-} 9 days). CT enhancement parameters were net maximal enhancement, net early enhancement and perfusion. The PET/CT scans showed intense FDG uptake in all primary tumours. Concordance rate between PET/CT and DCE CT for breast tumour localization was 92 %. No significant correlation was found between SUVmax and CT enhancement parameters in primary tumours (p > 0.6). PET/CT and DCE CT results were poorly correlated for skin infiltration (kappa = 0.19). Ipsilateral foci of increased axillary FDG uptake were found in 47 patients (median SUV: 7.9 {+-} 5.4), whereas enlarged axillary lymph nodes were observed on DCE CT in 43 patients. Results for axillary node involvement were fairly well correlated (kappa = 0.55). Nineteen patients (38 %) were found to be metastatic on PET/CT scan with a significant shorter progression-free survival than patients without distant lesions (p = 0.01). In the primary tumour, no statistically significant difference was observed between high and moderate tumour FDG uptake on survival, using an SUVmax cut-off of 5 (p = 0.7 and 0.9), or between high and low tumour enhancement on DCE CT (p > 0.8). FDG PET/CT imaging provided additional information concerning locoregional involvement to that provided by DCE CT on and allowed detection of distant metastases in the same whole-body procedure. Tumour FDG uptake or CT enhancement parameters were not correlated and were not found to have any prognostic value. (orig.)

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... over time. top of page What are the benefits vs. risks? Benefits CT scanning is painless, noninvasive and accurate. A ... bear denotes child-specific content. Related Articles and Media Radiation Dose in X-Ray and CT Exams ...

  9. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... over time. top of page What are the benefits vs. risks? Benefits A CT scan is one of the safest ... scanning is painless, noninvasive and accurate. A major advantage of CT is its ability to image bone, ...

  10. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... over time. top of page What are the benefits vs. risks? Benefits Viewing a CT scan, an experienced radiologist can ... scanning is painless, noninvasive and accurate. A major advantage of CT is its ability to image bone, ...

  11. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... CD or DVD. CT images of internal organs, bones, soft tissue and blood vessels provide greater detail than traditional ... advantage of CT is its ability to image bone, soft tissue and blood vessels all at the same time. ...

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... CD or DVD. CT images of internal organs, bones, soft tissue and blood vessels provide greater detail than traditional ... advantage of CT is its ability to image bone, soft tissue and blood vessels all at the same time. ...

  13. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... CD or DVD. CT images of internal organs, bones, soft tissue and blood vessels provide greater detail than traditional ... advantage of CT is its ability to image bone, soft tissue and blood vessels all at the same time. ...

  14. Interobserver Delineation variation using CT versus combined CT + MRI in intensity- modulated radiotherapy for prostate cancer

    International Nuclear Information System (INIS)

    Villeirs, G.M.; Verstraete, K.L.; Vaerenbergh, K. van; Vakaet, L.; Bral, S.; Claus, F.; Neve, W.J. de; Meerleer, G.O. de

    2005-01-01

    Purpose: to quantify interobserver variation of prostate and seminal vesicle delineations using CT only versus CT + MRI in consensus reading with a radiologist. Material and methods: the prostate and seminal vesicles of 13 patients treated with intensity-modulated radiotherapy for prostatic adenocarcinoma were retrospectively delineated by three radiation oncologists on CT only and on CT + MRI in consensus reading with a radiologist. The volumes and margin positions were calculated and intermodality and interobserver variations were assessed for the clinical target volume (CTV), seminal vesicles, prostate and three prostatic subdivisions (apical, middle and basal third). Results: using CT + MRI as compared to CT alone, the mean CTV, prostate and seminal vesicle volumes significantly decreased by 6.54%, 5.21% and 10.47%, respectively. More importantly, their standard deviations significantly decreased by 63.06%, 62.65% and 44.83%, respectively. The highest level of variation was found at the prostatic apex, followed by the prostatic base and seminal vesicles. Conclusion: addition of MRI to CT in consensus reading with a radiologist results in a moderate decrease of the CTV, but an important decrease of the interobserver delineation variation, especially at the prostatic apex. (orig.)

  15. The CT diagnosis and operative indication for panperitonitis carcinomatosa with intestinal obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Kitahara, Shinzo; Shirakura, Tatsuya; Kanemitsu, Hiroyuki; Shimada, Nagato; Nonaka, Kyoei; Hashimura, Chiaki; Shiba, Tadaaki; Tsugu, Yukio [Toho Univ., Tokyo (Japan). School of Medicine

    1997-05-01

    For the purpose of clarifying the discrimination points in the CT diagnosis of peritonitis carcinomatosa and operative indication for the disease, 52 patients with peritonitis carcinomatosa presenting with intestinal obstruction admitted to the hospital in a 5-year period (January 1990 to December 1994) were retrospectively studied, by comparing to another 22 cases of benign ileus in which CT was performed. As for the CT images, the following 10 items were evaluated: ascites, epiploic thickening, intestinal mass, intraperitoneal tumor, intestinal wall thickening, the mesenteric macule-shaped and funicular views, intestinal liquid being full, expansion intestinal tract gas, visualization of the Kerckring folds and mirror surface formation. Furthermore, the additional five items were examined as reference views: pleural effusion, liver metastasis, bile duct occlusion, hydronephrosis and paraaortic lymphnode swelling. The degree of each view was scored. When an average score in total was asked, it was 5.3{+-}2.9 S.D. in peritonitis carcinomatosa or -1.6{+-}2.9 S.D. in the benign ileus, with sensitivity of 95.7%, specificity of 76.7%, and accuracy of 90.0%. This score evaluation is useful to make a diagnosis of peritonitis carcinomatosa with intestinal obstruction. As to operative indication, possibilities are suggested that patients showing a mirror surface image can be candidates for excision of the intestine and anastomosis and that patients having hydronephrosis should not be candidates for operation. (author)

  16. Comparative analysis of multi-slice spiral CT and positron emission tomography-CT in evaluation of axillary lymph nodes in breast cancer patients

    International Nuclear Information System (INIS)

    Sun Xianchang; Zhang Ruyi; Liu Qingwei; Zhao Suhong; Zu Degui; Li Xin

    2008-01-01

    Objective: To evaluate and compare spiral CT and positron emission tomography-CT (PET-CT) in characterization of of axillary lymph nodes in breast cancer patients. Methods: Forty patients with pathologically proven breast cancer underwent contrast-enhanced spiral CT of the breast and axilla, 13 of them also underwent PET-CT examination. One hundred and fifty-eight axillary lymph nodes were found in the 40 patients through contrast enhanced spiral CT, while 57 lymph nodes were found in the 13 patients through PET-CT. Three radiologists rated the lymph nodes found in CT images on a five-point scale. If the score was equal to or greater than 3, it was defined as positive (metastatic), otherwise negative. Visual observation and semiquantitative analysis were used to classify lymph nodes in PET-CT images. The results of spiral CT observation and PET-CT observation of lymph nodes were compared with pathological results. The relative value of CT and PET-CT was analyzed. Exact probability statistics were employed. Results: One hundred and fifty eight lymph nodes of 40 patients were detected by spiral CT, 91 of them were diagnosed as positive and 67 as negative Among the lymph nodes found in spiral CT, 99 were positive and 59 were negative pathologicall. A total of 57 lymph nodes were found by PET-CT. Thirty-nine of them were defined as positive and 18 as negative. Among the lymph nodes found in PET-CT, 39 were positive and 18 were negative pathologically. The sensitivity, specificity, accuracy, positive and negative predictive values in CT prediction in axillary lymph nodes metastases were 88.89%, 94.91%, 91.14%, 96.70%, and 83.58%, respectively. The sensitivity, specificity, accuracy, positive and negative predictive values in PET-CT prediction in axillary lymph nodes metastases were 97.44%, 94.44%, 96.49%, 97.44%, and 94.44%, respectively. PET-CT had no significant difference with spiral CT in sensitivity, accuracy, positive and negative predictive values for detection

  17. CT scan findings of fungal pneumonia; Diagnose der Pilzpneumonie in der Thorax-CT

    Energy Technology Data Exchange (ETDEWEB)

    Heckmann, M.; Uder, M.; Bautz, W.; Heinrich, M. [Erlangen-Nuernberg Univ., Erlangen (Germany). Inst. fuer Diagnostische Radiologie

    2008-07-01

    The importance of fungal infection of the lung in immunocompromised patients has increased substantially during the last decades. Numerically the most patients are those with neutropenia, e.g. patients with malignancies or solid organ and stem cell transplantation, chemotherapy, corticosteroid use and HIV infection. Although fungal infections can occur in immunocompetent patients, their frequency in this population is rare. The clinical symptoms such as fever accompanied with non-productive cough are unspecific. In some patients progression to hypoxemia and dyspnea may occur rapidly. In spite of improved antifungal therapy morbidity and mortality of these infections are still high. Therefore an early and non-invasive diagnosis is very important. That is why CT and even better High-Resolution-CT (HR-CT) is a very important modality in examining immunocompromised patients with a probability of fungal infection. CT is everywhere available and, as a non-invasive method, able to give the relevant diagnose efficiently. This paper should give an overview about the radiologic findings and possible differential diagnosis of diverse pulmonary fungal infections in CT. Pneumonias caused by Aspergillus, Cryptococcus, Candida, Histoplasma, Mucor and Geotrichum capitatum are illustrated. (orig.)

  18. CT findings of the thymus

    International Nuclear Information System (INIS)

    Kang, Eun Young; Kim, Yun Hwan; Seol, Hae Young; Chung, Woun Kyun; Suh, Won Hyuck

    1987-01-01

    In 14 cases of normal and abnormal thymus proved surgically and histopathologically in korea University Hae Wha Hospital during recent 6 years, the clinical and CT findings were analyzed. 1. Of 14 cases, 2 cases were normal thymus, 5 cases were thymic hyperplasia, 4 cases were benign thymoma, 2 case were malignant thymoma and 1 case was thymic cyst. 2. Of 14 cases, 10 cases were associated with myasthenia gravis, and 7 of these 10 cases were 3rd to 5th decades females. Among 10 cases with myasthenia gravis. 5 cases were thymic hyperplasia, 1 case was benign thymoma, 2 cases were malignant thymoma, and 2 cases were normal thymus. 3. All 5 thymic hyperplasia were associated with myasthenia gravis. CT findings of thymic hyperplasia were normal in 4 cases and increased lobe thickness in 1 case. 4. Of 4 cases of benign thymoma, only 1 case was associated with myasthenia gravis, and all 4 cases were positive findings in CT scan. CT findings of benign thymoma were round or oval soft tissue mass in anterior mediastinum, and 1 case had punctuate calcifications. 5. Of 2 cases of malignant thymoma, all 2 cases were associated with myasthenia gravis and positive findings in CT scan. CT findings of malignant thymoma were anterior mediastinal soft tissue mass with obliteration of the normal fat planes surrounding great vessels. SVC compression, and pleural tumor implants. 6. CT yielded significant diagnostic information of differential diagnosis between thymoma and thymoma hyperplasia in myasthenia gravis patients. Also CT was highly sensitive test in detection of thymoma and determined the extent and invasiveness of thymoma.

  19. CT findings of the thymus

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Eun Young; Kim, Yun Hwan; Seol, Hae Young; Chung, Woun Kyun; Suh, Won Hyuck [Korea University College of Medicine, Seoul (Korea, Republic of)

    1987-02-15

    In 14 cases of normal and abnormal thymus proved surgically and histopathologically in korea University Hae Wha Hospital during recent 6 years, the clinical and CT findings were analyzed. 1. Of 14 cases, 2 cases were normal thymus, 5 cases were thymic hyperplasia, 4 cases were benign thymoma, 2 case were malignant thymoma and 1 case was thymic cyst. 2. Of 14 cases, 10 cases were associated with myasthenia gravis, and 7 of these 10 cases were 3rd to 5th decades females. Among 10 cases with myasthenia gravis. 5 cases were thymic hyperplasia, 1 case was benign thymoma, 2 cases were malignant thymoma, and 2 cases were normal thymus. 3. All 5 thymic hyperplasia were associated with myasthenia gravis. CT findings of thymic hyperplasia were normal in 4 cases and increased lobe thickness in 1 case. 4. Of 4 cases of benign thymoma, only 1 case was associated with myasthenia gravis, and all 4 cases were positive findings in CT scan. CT findings of benign thymoma were round or oval soft tissue mass in anterior mediastinum, and 1 case had punctuate calcifications. 5. Of 2 cases of malignant thymoma, all 2 cases were associated with myasthenia gravis and positive findings in CT scan. CT findings of malignant thymoma were anterior mediastinal soft tissue mass with obliteration of the normal fat planes surrounding great vessels. SVC compression, and pleural tumor implants. 6. CT yielded significant diagnostic information of differential diagnosis between thymoma and thymoma hyperplasia in myasthenia gravis patients. Also CT was highly sensitive test in detection of thymoma and determined the extent and invasiveness of thymoma.

  20. Quantitative dual energy CT measurements in rabbit VX2 liver tumors: Comparison to perfusion CT measurements and histopathological findings

    International Nuclear Information System (INIS)

    Zhang, Long Jiang; Wu, Shengyong; Wang, Mei; Lu, Li; Chen, Bo; Jin, Lixin; Wang, Jiandong; Larson, Andrew C.; Lu, Guang Ming

    2012-01-01

    Purpose: To evaluate the correlation between quantitative dual energy CT and perfusion CT measurements in rabbit VX2 liver tumors. Materials and methods: This study was approved by the institutional animal care and use committee at our institution. Nine rabbits with VX2 liver tumors underwent contrast-enhanced dual energy CT and perfusion CT. CT attenuation for the tumors and normal liver parenchyma and tumor-to-liver ratio were obtained at the 140 kVp, 80 kVp, average weighted images and dual energy CT iodine maps. Quantitative parameters for the viable tumor and adjacent liver were measured with perfusion CT. The correlation between the enhancement values of the tumor in iodine maps and perfusion CT parameters of each tumor was analyzed. Radiation dose from dual energy CT and perfusion CT was measured. Results: Enhancement values for the tumor were higher than that for normal liver parenchyma at the hepatic arterial phase (P < 0.05). The highest tumor-to-liver ratio was obtained in hepatic arterial phase iodine map. Hepatic blood flow of the tumor was higher than that for adjacent liver (P < 0.05). Enhancement values of hepatic tumors in the iodine maps positively correlated with permeability of capillary vessel surface (r = 0.913, P < 0.001), hepatic blood flow (r = 0.512, P = 0.010), and hepatic blood volume (r = 0.464, P = 0.022) at the hepatic arterial phases. The effective radiation dose from perfusion CT was higher than that from DECT (P < 0.001). Conclusions: The enhancement values for viable tumor tissues measured in iodine maps were well correlated to perfusion CT measurements in rabbit VX2 liver tumors. Compared with perfusion CT, dual energy CT of the liver required a lower radiation dose.

  1. 3D CT versus axial helical CT versus conventional tomography in the classification of acetabular fractures: A ROC analysis

    International Nuclear Information System (INIS)

    Kickuth, Ralph; Laufer, Ulf; Hartung, Guido; Gruening, Christian; Stueckle, Christoph; Kirchner, Johannes

    2002-01-01

    AIM: To assess the diagnostic power of three-dimensional computed tomography (3D CT), axial helical computed tomography (CT) and conventional tomography in the classification of acetabular fractures by interdisciplinary review. MATERIALS AND METHODS: Receiver operating characteristics (ROCs) were assessed for two radiologists and two surgeons blinded to the presence of acetabular fractures in an animal model (a total of 62 porcine hips, 40 of them with artificial acetabular fractures). Main target parameter was the diagnostic accuracy in the classification of the artificial fractures following Judet et al. RESULTS: ROC analysis for radiologists showed A z values of 0·83 for 3D CT, 0·81 for axial helical CT, and 0·78 for conventional tomography; differences between the three techniques were not significant (P = 0·46-0·73). A z values for the surgeons were 0·87 for 3D CT, 0·68 for axial helical CT, and 0·60 for conventional tomography; 3D CT was significantly better than axial helical CT (P = 0·01) and conventional tomography (P = 0·001). The differences between axial helical CT and conventional tomography were not significant (P = 0·37). CONCLUSION: Acetabular fractures are best classified by 3D CT, followed by axial helical CT and conventional tomography when assessed by surgeons. 3D CT did not provide any additional significant benefit in the classification performed by radiologists. Kickuth, R. et al. (2002)

  2. Cardiac pathologies incidentally detected with non-gated chest CT; Inzidentelle Pathologien des Herzens im Thorax-CT

    Energy Technology Data Exchange (ETDEWEB)

    Scherer, Axel; Kroepil, P.; Lanzman, R.S.; Moedder, U. [Inst. fuer Radiologie, Universitaetsklinikum Duesseldorf, Heinrich-Heine-Univ. (Germany); Choy, G.; Abbara, S. [Cardiovascular Imaging Section, Massachusetts General Hospital, Harvard Medical School (United States)

    2009-12-15

    Cardiac imaging using electrocardiogram-gated multi-detector computed tomography (MDCT) permits noninvasive diagnosis of congenital and acquired cardiac pathologies and has thus become increasingly important in the last years. Several studies investigated the incidence and relevance of incidental extracardiac structures within the lungs, mediastinum, chest wall, and abdomen with gated coronary CT. This resulted in the general acceptance of the review of extracardiac structures as a routine component of coronary CT interpretation. On the other hand radiologists tend to neglect pericardial and cardiac pathologies in non-gated chest CT, which is primarily performed for the evaluation of the respiratory system or for tumor staging. Since the introduction of multi-detector spiral CT technology, the incidental detection of cardiac and pericardial findings has become possible using non-gated chest CT. This article reviews the imaging appearances and differential diagnostic considerations of incidental cardiac entities that may be encountered in non-gated chest CT. (orig.)

  3. Multislice CT imaging of pulmonary embolism

    International Nuclear Information System (INIS)

    Schoepf, J.U.; Kessler, M.A.; Rieger, C.T.; Herzog, P.; Wiesgigl, S.; Becker, C.R.; Exarhos, D.N.; Reiser, M.F.

    2001-01-01

    In recent years CT has been established as the method of choice for the diagnosis of central pulmonary embolism (PE) to the level of the segmental arteries. The key advantage of CT over competing modalities is the reliable detection of relevant alternative or additional disease causing the patient's symptoms. Although the clinical relevance of isolated peripheral emboli remains unclear, the alleged poor sensitivity of CT for the detection of such small clots has to date prevented the acceptance of CT as the gold standard for diagnosing PE. With the advent of multislice CT we can now cover the entire chest of a patient with 1-mm slices within one breath-hold. In comparison with thicker sections, the detection rate of subsegmental emboli can be significantly increased with 1-mm slices. In addition, the interobserver correlation which can be achieved with 1-mm sections by far exceeds the reproducibility of competing modalities. Meanwhile use of multislice CT for a combined diagnosis of PE and deep venous thrombosis with the same modality appears to be clinically accepted. In the vast majority of patients who receive a combined thoracic and venous multislice CT examination the scan either confirms the suspected diagnosis or reveals relevant alternative or additional disease. The therapeutic regimen is usually chosen based on the functional effect of embolic vascular occlusion. With the advent of fast CT scanning techniques, also functional parameters of lung perfusion can be non-invasively assessed by CT imaging. These advantages let multislice CT appear as an attractive modality for a non-invasive, fast, accurate, and comprehensive diagnosis of PE, its causes, effects, and differential diagnoses. (orig.)

  4. PET/CT imaging in head and neck tumors

    International Nuclear Information System (INIS)

    Roedel, R.; Palmedo, H.; Reichmann, K.; Reinhardt, M.J.; Biersack, H.J.; Straehler-Pohl, H.J.; Jaeger, U.

    2004-01-01

    To evaluate the usefulness of combined PET/CT examinations for detection of malignant tumors and their metastases in head and neck oncology. 51 patients received whole body scans on a dual modality PET/CT system. CT was performed without i.v. contrast. The results were compared concerning the diagnostic impact of native CT scan on FDG-PET images and the additional value of fused imaging. From 153 lesions were 97 classified as malignant on CT and 136 on FDG/PET images, as suspicious for malignancy in 33 on CT and 7 on FDG-PET and as benign in 23 on CT and 10 on FDG-PET. With combined PET/CT all primary and recurrent tumors could be found, the detection rate in patients with unknown primary tumors was 45%. Compared to PET or CT alone the sensitivity, specifity and accuracy could be significantly improved by means of combined PET/CT. Fused PET/CT imaging with [F18]-FDG and native CT-scanning enables accurate diagnosis in 93% of lesions and 90% of patients with head and neck oncology. (orig.) [de

  5. CT findings in neonatal hypothermia

    International Nuclear Information System (INIS)

    Schulman, H.; Laufer, L.; Berginer, J.; Hertzanu, Y.; Hershkowitz, E.; Berenstein, T.; Sofer, S.; Maor, E.

    1998-01-01

    Background. Newborn infants are particularly prone to hypothermia, a condition with a high mortality. Objective. To study the CT brain patterns in infants with hypothermia and neurological symptoms. Materials and methods. We reviewed the brain CT of nine infants with neonatal hypothermia, multiple organ failure, seizures and coma. Results. Two infants had normal CT scans, acutely and at follow-up, and were clinically normal at follow-up. In seven infants, CT showed diffuse cerebral oedema, with reversal of the normal density relationship between grey and white matter and a relative increased density of the thalami, brainstem and cerebellum - the 'reversal sign'. In six surviving infants with severe developmental delay, follow-up CT revealed cerebral atrophy with multicystic encephalomalacia. Conclusions. The 'reversal sign' has been described in the abused child, birth asphyxia and anoxia due to drowning. Neonatal hypothermia is offered as a further cause. (orig.)

  6. Radiation exposure in CT-guided interventions

    Energy Technology Data Exchange (ETDEWEB)

    Kloeckner, Roman, E-mail: Roman.Kloeckner@unimedizin-mainz.de [Department of Diagnostic and Interventional Radiology, Johannes Gutenberg-University, Langenbeckstraße 1, 55131 Mainz (Germany); Santos, Daniel Pinto dos; Schneider, Jens [Department of Diagnostic and Interventional Radiology, Johannes Gutenberg-University, Langenbeckstraße 1, 55131 Mainz (Germany); Kara, Levent [Department of Radiology, Inselspital Bern, Freiburgstraße 18, 3010 Bern (Switzerland); Dueber, Christoph; Pitton, Michael B. [Department of Diagnostic and Interventional Radiology, Johannes Gutenberg-University, Langenbeckstraße 1, 55131 Mainz (Germany)

    2013-12-01

    Purpose: To investigate radiation exposure in computed tomography (CT)-guided interventions, to establish reference levels for exposure, and to discuss strategies for dose reduction. Materials and methods: We analyzed 1576 consecutive CT-guided procedures in 1284 patients performed over 4.5 years, including drainage placements; biopsies of different organs; radiofrequency and microwave ablations (RFA/MWA) of liver, bone, and lung tumors; pain blockages, and vertebroplasties. Data were analyzed with respect to scanner settings, overall radiation doses, and individual doses of planning CT series, CT intervention, and control CT series. Results: Eighy-five percent of the total radiation dose was applied during the pre- and post-interventional CT series, leaving only 15% applied by the CT-guided intervention itself. Single slice acquisition was associated with lower doses than continuous CT-fluoroscopy (37 mGy cm vs. 153 mGy cm, p < 0.001). The third quartile of radiation doses varied considerably for different interventions. The highest doses were observed in complex interventions like RFA/MWA of the liver, followed by vertebroplasty and RFA/MWA of the lung. Conclusions: This paper suggests preliminary reference levels for various intervention types and discusses strategies for dose reduction. A multicenter registry of radiation exposure including a broader spectrum of scanners and intervention types is needed to develop definitive reference levels.

  7. CT findings in Reye syndrome

    International Nuclear Information System (INIS)

    Lee, Kil Woo; Lim, Hyo Keun; Choo, In Wook; Bae, Sang Hoon

    1990-01-01

    We present here the CT findings in 10 patients with Reye syndrome. Acute findings is diffuse cerebral swelling with or without parenchymal low density. The cerebral swelling gradually changed to atrophy. The parenchymal low density predisposes in Lt temporoparietal area. Contrast enhanced CT scan showed no additional finding, except 1 case. The hemorrhagic infarction which has not been reported previously was seen in 1 case and resulted in the most prominent sequela. The sequelae were developed in all atrophic cases. So, the brain CT may be useful in monitoring cerebral swelling, determining treatment plan in acute stage, and in presenting prognosis and sequelae on fellow up CT

  8. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... can help plan the safest and most effective surgery. CT of the sinuses is now widely available and is performed in a relatively short time, especially when compared to magnetic resonance imaging (MRI). CT scanning is painless, noninvasive and ...

  9. Coronary CT angiography: Diagnostic value and clinical challenges.

    Science.gov (United States)

    Sabarudin, Akmal; Sun, Zhonghua

    2013-12-26

    Coronary computed tomography (CT) angiography has been increasingly used in the diagnosis of coronary artery disease due to improved spatial and temporal resolution with high diagnostic value being reported when compared to invasive coronary angiography. Diagnostic performance of coronary CT angiography has been significantly improved with the technological developments in multislice CT scanners from the early generation of 4-slice CT to the latest 320- slice CT scanners. Despite the promising diagnostic value, coronary CT angiography is still limited in some areas, such as inferior temporal resolution, motion-related artifacts and high false positive results due to severe calcification. The aim of this review is to present an overview of the technical developments of multislice CT and diagnostic value of coronary CT angiography in coronary artery disease based on different generations of multislice CT scanners. Prognostic value of coronary CT angiography in coronary artery disease is also discussed, while limitations and challenges of coronary CT angiography are highlighted.

  10. Influence of the gas phase composition on nanocrystalline diamond films prepared by MWCVD

    Czech Academy of Sciences Publication Activity Database

    Popov, C.; Jelínek, Miroslav; Boycheva, S.; Vorlíček, Vladimír; Kulisch, W.

    2005-01-01

    Roč. 23, - (2005), s. 31-34 ISSN 1422-6375 R&D Projects: GA AV ČR(CZ) IAA1010110 Grant - others:European Community Marie Curie Fellowship(XE) HPMF-CT-2002-01713 Institutional research plan: CEZ:AV0Z1010914 Keywords : microwave plasma CVD * nanocrystalline diamond films * characterization Subject RIV: BL - Plasma and Gas Discharge Physics

  11. CT findings in ischaemic hepatic failure due to intra-arterial embolisation: A case report

    International Nuclear Information System (INIS)

    Catalano, O.

    1997-01-01

    Liver infarction is relatively uncommon. It may be secondary to several conditions such as sepsis, shock, sickle-cell anaemia, eclampsia, vasculitis, metastatic disease, bacterial endocarditis, rheumatic heart disease, trauma, portal venous occlusion or compression, oral contraception, anaesthesia, hepatic artery thrombosis, therapeutical or inadvertent hepatic artery ligation, intra-arterial chemotherapy or embolisation. A case of hepatic infraction, unusual for iatrogenic pathogenesis, submassive extension with acute hepatic failure, and CT findings of an internally branching pattern due to intravascular gas was observed. (orig./AJ)

  12. Integration of PET-CT and cone-beam CT for image-guided radiotherapy with high image quality and registration accuracy

    Science.gov (United States)

    Wu, T.-H.; Liang, C.-H.; Wu, J.-K.; Lien, C.-Y.; Yang, B.-H.; Huang, Y.-H.; Lee, J. J. S.

    2009-07-01

    Hybrid positron emission tomography-computed tomography (PET-CT) system enhances better differentiation of tissue uptake of 18F-fluorodeoxyglucose (18F-FDG) and provides much more diagnostic value in the non-small-cell lung cancer and nasopharyngeal carcinoma (NPC). In PET-CT, high quality CT images not only offer diagnostic value on anatomic delineation of the tissues but also shorten the acquisition time for attenuation correction (AC) compared with PET-alone imaging. The linear accelerators equipped with the X-ray cone-beam computed tomography (CBCT) imaging system for image-guided radiotherapy (IGRT) provides excellent verification on position setup error. The purposes of our study were to optimize the CT acquisition protocols of PET-CT and to integrate the PET-CT and CBCT for IGRT. The CT imaging parameters were modified in PET-CT for increasing the image quality in order to enhance the diagnostic value on tumour delineation. Reproducibility and registration accuracy via bone co-registration algorithm between the PET-CT and CBCT were evaluated by using a head phantom to simulate a head and neck treatment condition. Dose measurement in computed tomography dose index (CTDI) was also estimated. Optimization of the CT acquisition protocols of PET-CT was feasible in this study. Co-registration accuracy between CBCT and PET-CT on axial and helical modes was in the range of 1.06 to 2.08 and 0.99 to 2.05 mm, respectively. In our result, it revealed that the accuracy of the co-registration with CBCT on helical mode was more accurate than that on axial mode. Radiation doses in CTDI were 4.76 to 18.5 mGy and 4.83 to 18.79 mGy on axial and helical modes, respectively. Registration between PET-CT and CBCT is a state-of-the-art registration technology which could provide much information on diagnosis and accurate tumour contouring on radiotherapy while implementing radiotherapy procedures. This novelty technology of PET-CT and cone-beam CT integration for IGRT may have a

  13. Integration of PET-CT and cone-beam CT for image-guided radiotherapy with high image quality and registration accuracy

    International Nuclear Information System (INIS)

    Wu, T-H; Liang, C-H; Wu, J-K; Lien, C-Y; Yang, B-H; Lee, J J S; Huang, Y-H

    2009-01-01

    Hybrid positron emission tomography-computed tomography (PET-CT) system enhances better differentiation of tissue uptake of 18 F-fluorodeoxyglucose ( 18 F-FDG) and provides much more diagnostic value in the non-small-cell lung cancer and nasopharyngeal carcinoma (NPC). In PET-CT, high quality CT images not only offer diagnostic value on anatomic delineation of the tissues but also shorten the acquisition time for attenuation correction (AC) compared with PET-alone imaging. The linear accelerators equipped with the X-ray cone-beam computed tomography (CBCT) imaging system for image-guided radiotherapy (IGRT) provides excellent verification on position setup error. The purposes of our study were to optimize the CT acquisition protocols of PET-CT and to integrate the PET-CT and CBCT for IGRT. The CT imaging parameters were modified in PET-CT for increasing the image quality in order to enhance the diagnostic value on tumour delineation. Reproducibility and registration accuracy via bone co-registration algorithm between the PET-CT and CBCT were evaluated by using a head phantom to simulate a head and neck treatment condition. Dose measurement in computed tomography dose index (CTDI) was also estimated. Optimization of the CT acquisition protocols of PET-CT was feasible in this study. Co-registration accuracy between CBCT and PET-CT on axial and helical modes was in the range of 1.06 to 2.08 and 0.99 to 2.05 mm, respectively. In our result, it revealed that the accuracy of the co-registration with CBCT on helical mode was more accurate than that on axial mode. Radiation doses in CTDI were 4.76 to 18.5 mGy and 4.83 to 18.79 mGy on axial and helical modes, respectively. Registration between PET-CT and CBCT is a state-of-the-art registration technology which could provide much information on diagnosis and accurate tumour contouring on radiotherapy while implementing radiotherapy procedures. This novelty technology of PET-CT and cone-beam CT integration for IGRT may have a

  14. Percutaneous CT-guided high-dose brachytherapy (CT-HDRBT) ablation of primary and metastatic lung tumors in nonsurgical candidates; Perkutane CT-gesteuerte Hochdosis-Brachytherapie (CT-HDRBT) von primaeren und metastatischen Lungentumoren in nicht chirurgischen Kandidaten

    Energy Technology Data Exchange (ETDEWEB)

    Collettini, F.; Schnapauff, D.; Poellinger, A.; Denecke, T.; Banzer, J.; Golenia, M.J.; Gebauer, B. [Charite - Universitatesmedizin Berlin (Germany). Inst. fuer Radiologie; Wust, P. [Charite - Universitatesmedizin Berlin (Germany). Klinik fuer Strahlentherapie

    2012-04-15

    To evaluate the safety and efficacy of CT-guided high-dose brachytherapy (CT-HDRBT) ablation of primary and metastatic lung tumors. Between November 2007 and May 2010, all consecutive patients with primary or metastatic lung tumors, unsuitable for surgery, were treated with CT-HDRBT. Imaging follow-up after treatment was performed with contrast-enhanced CT at 6 weeks, 3 months and every 6 months after the procedure. The endpoints of the study were local tumor control and time to progression. The Kaplan-Meier method was used to estimate survival functions and local tumor progression rates. 34 procedures were carried out on 33 lesions in 22 patients. The mean diameter of the tumors was 33.3 mm (SD = 20.4). The first contrast-enhanced CT showed that complete ablation was achieved in all lesions. The mean minimal tumor enclosing dose was 18.9 Gy (SD = 2). Three patients developed a pneumothorax after the procedure. The mean follow-up time was 13.7 (3 - 29) months. 2 of 32 lesions (6.25 %) developed a local tumor progression. 8 patients (36.3 %) developed a distant tumor progression. After 17.7 months, 13 patients were alive and 9 patients had died. CT-HDRBT ablation is a safe and attractive treatment option for patients with lung malignancies and allows targeted destruction of tumor tissue with simultaneous preservation of important lung structures. Furthermore, CT-HDRBT is independent of the size of the lesion and its location within the lung parenchyma. (orig.)

  15. Serial CT Findings of Paragonimus Infested Dogs and the Micro-CT Findings of the Worm Cysts

    International Nuclear Information System (INIS)

    Lee, Chang Hyun; Im, Jung Gi; Goo, Jin Mo; Lee, Hyun Ju; Hong, Sung Tae; Shen, Cheng Hua; Chung, Doo Hyun; Son, Kyu Ri; Chang, Jung Min; Eo, Hong

    2007-01-01

    To investigate the serial CT findings of Paragonimus westermani infected dogs and the microscopic structures of the worm cysts using Micro-CT. This study was approved by the committee on animal research at our institution. Fifteen dogs infected with P. westermani underwent serial contrast-enhanced CT scans at pre-infection, after 10 days of infection, and monthly thereafter until six months for determining the radiologic-pathologic correlation. Three dogs (one dog each time) were sacrificed at 1, 3 and 6 months, respectively. After fixation of the lungs, both multi-detector CT and Micro-CT were performed for examining the worm cysts. The initial findings were pleural effusion and/or subpleural groundglass opacities or linear opacities at day 10. At day 30, subpleural and peribronchial nodules appeared with hydropneumothorax and abdominal or chest wall air bubbles. Cavitary change and bronchial dilatation began to be seen on CT scan at day 30 and this was mostly seen together with mediastinal lymphadenopathy at day 60. Thereafter, subpleural ground-glass opacities and nodules with or without cavitary changes were persistently observed until day 180. After cavitary change of the nodules, the migratory features of the subpleural or peribronchial nodules were seen on all the serial CT scans. Micro-CT showed that the cyst wall contained dilated interconnected tubular structures, which had communications with the cavity and the adjacent distal bronchus. The CT findings of paragonimiasis depend on the migratory stage of the worms. The worm cyst can have numerous interconnected tubular channels within its own wall and these channels have connections with the cavity and the adjacent distal bronchus

  16. Minimum miscibility pressure estimation for a CO{sub 2}/n-decane system in porous media by X-ray CT

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yu; Jiang, Lanlan; Tang, Lingyue; Song, Yongchen; Zhao, Jiafei; Zhang, Yi; Wang, Dayong; Yang, Mingjun [Dalian University of Technology, Key Laboratory of Ocean Energy Utilization and Energy Conservation of Ministry of Education, Dalian (China)

    2015-07-15

    Accurate determination of gas-fluid miscibility conditions is important to optimize the displacement efficiency during CO{sub 2}-enhanced oil recovery. This paper presents a new technique to investigate the phase behavior and to estimate the minimum miscibility pressure (MMP) of a CO{sub 2}/n-decane system using an X-ray computerized tomography (CT) scanner. CT scans of the CO{sub 2}/n-decane system are taken at various pressures during the experiments. The image intensity values taken from the CT images have a linear relationship with the densities of the measured objects; therefore, we can estimate the miscible point of CO{sub 2} and n-decane because the difference between the intensity values for each phase decays to zero as the pressure increases toward the MMP. This paper provides experimental evidence for the validity of the new CT method by comparing the results with previous studies and presents an application of the method to investigate the MMP of the CO{sub 2}/n-decane system in porous media. Additionally, the influence of porous media on the equilibrium state when the CO{sub 2}/n-decane system is close to miscibility is discussed. (orig.)

  17. Clinical application of CT and CT-guided percutaneous transthoracic needle biopsy in patients with indeterminate pulmonary nodules

    Energy Technology Data Exchange (ETDEWEB)

    Cardoso, Luciana Vargas; Souza Júnior, Arthur Soares, E-mail: fabianonatividade@terra.com.br [Rio Preto-Ultra-X Radiological Diagnosis Institute, São José do Rio Preto, SP (Brazil)

    2014-07-15

    Objective: To investigate the clinical application of CT and CT-guided percutaneous transthoracic needle biopsy (CT-PTNB) in patients with indeterminate pulmonary nodules (IPNs). Methods: We retrospectively studied 113 patients with PNs undergoing CT and CT-PTNB. Variables such as gender, age at diagnosis, smoking status, CT findings, and CT-PTNB techniques were analyzed. Data analysis was performed with the Student's t-test for independent samples the chi-square test, and normal approximation test for comparison of two proportions. Results: Of the 113 patients studied, 68 (60.2%) were male and 78 (69%) were smokers. The diameter of malignant lesions ranged from 2.6 cm to 10.0 cm. Most of the IPNs (85%) were located in the peripheral region. The biopsied IPNs were found to be malignant in 88 patients (77.8%) and benign in 25 (22.2%). Adenocarcinoma was the most common malignant tumor, affecting older patients. The IPN diameter was significantly greater in patients with malignant PNs than in those with benign IPNs (p < 0.001). Having regular contour correlated significantly with an IPN being benign (p = 0.022), whereas spiculated IPNs and bosselated IPNs were more often malignant (in 50.7% and 28.7%, respectively). Homogeneous attenuation and necrosis were more common in patients with malignant lesions (51.9% and 26.9%, respectively). Conclusions: In our sample, CT and CT-PTNB were useful in distinguishing between malignant and benign IPNs. Advanced age and smoking were significantly associated with malignancy. Certain CT findings related to IPNs (larger diameter, spiculated borders, homogeneous attenuation, and necrosis) were associated with malignancy. (author)

  18. Detectability index of differential phase contrast CT compared with conventional CT: a preliminary channelized Hotelling observer study

    Science.gov (United States)

    Tang, Xiangyang; Yang, Yi; Tang, Shaojie

    2013-03-01

    Under the framework of model observer with signal and background exactly known (SKE/BKE), we investigate the detectability of differential phase contrast CT compared with that of the conventional attenuation-based CT. Using the channelized Hotelling observer and the radially symmetric difference-of-Gaussians channel template , we investigate the detectability index and its variation over the dimension of object and detector cells. The preliminary data show that the differential phase contrast CT outperforms the conventional attenuation-based CT significantly in the detectability index while both the object to be detected and the cell of detector used for data acquisition are relatively small. However, the differential phase contrast CT's dominance in the detectability index diminishes with increasing dimension of either object or detector cell, and virtually disappears while the dimension of object or detector cell approaches a threshold, respectively. It is hoped that the preliminary data reported in this paper may provide insightful understanding of the differential phase contrast CT's characteristic in the detectability index and its comparison with that of the conventional attenuation-based CT.

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... images or pictures of the inside of the body. The cross-sectional images generated during a CT scan can be reformatted ... of data to create two-dimensional cross-sectional images of your body, which are then displayed on a monitor. CT ...

  20. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... images or pictures of the inside of the body. The cross-sectional images generated during a CT scan can be reformatted ... of data to create two-dimensional cross-sectional images of your body, which are then displayed on a monitor. CT ...

  1. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... images or pictures of the inside of the body. The cross-sectional images generated during a CT scan can be reformatted ... of data to create two-dimensional cross-sectional images of your body, which are then displayed on a monitor. CT ...

  2. CT urography and hematuria

    DEFF Research Database (Denmark)

    Bretlau, Thomas; Hansen, Rasmus H; Thomsen, Henrik S

    2015-01-01

    BACKGROUND: Computed tomography (CT) urography is now used in the work-up of patients with hematuria. The dose of contrast medium and radiation varies considerably between the different CT protocols. PURPOSE: To study the disease prevalence in a consecutive group of patients with hematuria...

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... about tumors of the nasal cavity and sinuses. plan for surgery by defining anatomy. top of page How should ... for sinusitis. CT of the sinuses can help plan the safest and most effective surgery. CT of the sinuses is now widely available ...

  4. Dual energy cardiac CT.

    Science.gov (United States)

    Carrascosa, Patricia; Deviggiano, Alejandro; Rodriguez-Granillo, Gastón

    2017-06-01

    Conventional single energy CT suffers from technical limitations related to the polychromatic nature of X-rays. Dual energy cardiac CT (DECT) shows promise to attenuate and even overcome some of these limitations, and might broaden the scope of patients eligible for cardiac CT towards the inclusion of higher risk patients. This might be achieved as a result of both safety (contrast reduction) and physiopathological (myocardial perfusion and characterization) issues. In this article, we will review the main clinical cardiac applications of DECT, that can be summarized in two core aspects: coronary artery evaluation, and myocardial evaluation.

  5. CT diagnosis in diseases of the breast

    International Nuclear Information System (INIS)

    Han Hongbin; Xie Jingxia

    1998-01-01

    Purpose: To study the CT signs of breast diseases, and discuss the value of CT in the diagnosis of breast cancer and the axillary lymph node (LN) metastases. Materials and methods: Fifty three cases were reported, including breast cancer 30 cases and benign diseases 23 cases. CT were performed in all patients, 44 also had mammography examination. Results: (1) The CT appearance of breast cancer: round or irregular mass, spiculate border, duct retraction, involved Cooper's ligament, deformed adipose space etc. Benign hyperplasia: Irregular mass and symmetrical thickening of breast glands. Cystic hyperplasia: typically multiple, round, liquid-density mass. (2) CT was comparable to mammography in terms of differential diagnosis, however with breast mass located near the axilla or for evaluation of the thoracic wall. CT was superior to mammography. CT was also helpful in detecting LN metastases. Conclusion: CT is valuable in detecting and differentiating breast diseases as well as in the diagnosis of LN metastases

  6. Oncologic PET/CT: current status and controversies

    International Nuclear Information System (INIS)

    Siegel, B.A.; Dehdashti, F.

    2005-01-01

    The introduction of integrated PET/CT has dramatically increased the worldwide rate of growth for PET, predominantly for oncologic imaging with the glucose analog 18 F-fluorodeoxyglucose (FDG). A rapidly expanding body of literature demonstrates that the use FDG-PET/CT and the resultant ability to interpret coregistered and fused PET and CT images lead to improved observer confidence and improved diagnostic performance by comparison with PET alone, CT alone, and visually correlated PET and CT. The value of PET/CT is likely to be even greater with new PET radiopharmaceuticals under development, many of which produce PET images with even fewer anatomical landmarks than FDG images. PET/CT is also likely to lead to the resurrection of 18 F-fluoride as a principal agent for radionuclide bone imaging. There are a number of controversies related to PET/CT, including minimum training and experience requirements for interpreting physicians and defining new models for technical and professional reimbursement. (orig.)

  7. The sensitivity of computed tomography (CT) scans in detecting trauma: are CT scans reliable enough for courtroom testimony?

    Science.gov (United States)

    Molina, D Kimberley; Nichols, Joanna J; Dimaio, Vincent J M

    2007-09-01

    Rapid and accurate recognition of traumatic injuries is extremely important in emergency room and surgical settings. Emergency departments depend on computed tomography (CT) scans to provide rapid, accurate injury assessment. We conducted an analysis of all traumatic deaths autopsied at the Bexar County Medical Examiner's Office in which perimortem medical imaging (CT scan) was performed to assess the reliability of the CT scan in detecting trauma with sufficient accuracy for courtroom testimony. Cases were included in the study if an autopsy was conducted, a CT scan was performed within 24 hours before death, and there was no surgical intervention. Analysis was performed to assess the correlation between the autopsy and CT scan results. Sensitivity, specificity, positive predictive value, and negative predictive value were defined for the CT scan based on the autopsy results. The sensitivity of the CT scan ranged from 0% for cerebral lacerations, cervical vertebral body fractures, cardiac injury, and hollow viscus injury to 75% for liver injury. This study reveals that CT scans are an inadequate detection tool for forensic pathologists, where a definitive diagnosis is required, because they have a low level of accuracy in detecting traumatic injuries. CT scans may be adequate for clinicians in the emergency room setting, but are inadequate for courtroom testimony. If the evidence of trauma is based solely on CT scan reports, there is a high possibility of erroneous accusations, indictments, and convictions.

  8. CT findings in neonatal hypothermia

    Energy Technology Data Exchange (ETDEWEB)

    Schulman, H.; Laufer, L.; Berginer, J.; Hertzanu, Y. [Department of Radiology, Soroka Medical Center, Faculty of Health Sciences, Ben-Gurion University of the Negev, P. O. Box 151, Beer-Sheva 84101 (Israel); Hershkowitz, E.; Berenstein, T.; Sofer, S. [Pediatric Intensive Care Unit, Soroka Medical Center, Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer-Sheva (Israel); Maor, E. [Department of Pathology, Soroka Medical Center, Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer-Sheva (Israel)

    1998-06-01

    Background. Newborn infants are particularly prone to hypothermia, a condition with a high mortality. Objective. To study the CT brain patterns in infants with hypothermia and neurological symptoms. Materials and methods. We reviewed the brain CT of nine infants with neonatal hypothermia, multiple organ failure, seizures and coma. Results. Two infants had normal CT scans, acutely and at follow-up, and were clinically normal at follow-up. In seven infants, CT showed diffuse cerebral oedema, with reversal of the normal density relationship between grey and white matter and a relative increased density of the thalami, brainstem and cerebellum - the `reversal sign`. In six surviving infants with severe developmental delay, follow-up CT revealed cerebral atrophy with multicystic encephalomalacia. Conclusions. The `reversal sign` has been described in the abused child, birth asphyxia and anoxia due to drowning. Neonatal hypothermia is offered as a further cause. (orig.) With 6 figs., 1 tab., 13 refs.

  9. Anatomy and function: PET-CT.

    Science.gov (United States)

    Kajander, Sami; Saraste, Antti; Ukkonen, Heikki; Knuuti, Juhani

    2010-05-01

    CT coronary angiography and perfusion PET form an attractive combination to study coronary artery lesions and their consequences in patients with coronary artery disease. Whereas CT provides non-invasive assessment of coronary lumen and wall, PET perfusion is a reliable method for the evaluation of myocardial flow. CT, although very capable of ruling out significant coronary artery disease, is less than satisfactory in assessing the actual significance of the detected lesions. PET imaging, despite its excellent sensitivity, fails to describe the exact anatomy of the epicardial vessels. By fusing image data from these two modalities, lesions can be accurately correlated with their physiological or anatomical counterparts. Hybrid PET-CT devices, now in wide clinical use, allow such fusion in a one-stop-shop study. Although still seeking its place in clinical scenarios, growing evidence suggests that hybrid PET-CT imaging of coronary anatomy and myocardial perfusion can accurately - and non-invasively - assess the existence and degree of coronary artery disease.

  10. Hydrogen peroxide ingestion associated with portal venous gas and treatment with hyperbaric oxygen: a case series and review of the literature.

    Science.gov (United States)

    French, Loren Keith; Horowitz, B Zane; McKeown, Nathanael J

    2010-07-01

    Ingestion of concentrated hydrogen peroxide (H(2)O(2)) has been associated with venous and arterial gas embolic events, hemorrhagic gastritis, gastrointestinal bleeding, shock, and death. Although H(2)O(2) is generally considered a benign ingestion in low concentrations, case reports have described serious toxicity following high concentration exposures. Hyperbaric oxygen (HBO) has been used with success in managing patients suffering from gas embolism with and without manifestations of ischemia. Poison center records were searched from July 1999 to January 2010 for patients with H(2)O(2) exposure and HBO treatment. Cases were reviewed for the concentration of H(2)O(2), symptoms, CT scan findings of portal gas embolism, HBO treatment, and outcome. RESULTS; Eleven cases of portal gas embolism were found. Ages ranged from 4 to 89 years. All but one ingestion was accidental in nature. In 10 cases 35% H(2)O(2) was ingested and in 1 case 12% H(2)O(2) was ingested. All abdominal CT scans demonstrated portal venous gas embolism in all cases. Hyperbaric treatment was successful in completely resolving all portal venous gas bubbles in nine patients (80%) and nearly resolving them in two others. Ten patients were able to be discharged home within 1 day, and one patient had a 3.5-day length of stay. HBO was successful in resolving portal venous gas embolism from accidental concentrated H(2)O(2) ingestions.

  11. Complicated pleural tuberculosis in children: CT evaluation

    International Nuclear Information System (INIS)

    Moon, W.K.; Kim, W.S.; Kim, I.O.; Im, J.G.; Kim, J.H.; Yeon, K.M.; Han, M.C.

    1999-01-01

    Purpose. To describe the CT features of complicated pleural tuberculosis in children and to define the use of CT in children with pleural tuberculosis. Materials and methods. The CT findings in 11 children with complicated pleural tuberculosis were retrospectively analysed. CT was performed to evaluate persistent pleural thickening (n = 6) or a mass-like lesion (n = 5) detected on plain radiographs. Chest radiographs and medical records were reviewed to determine whether additional information provided by CT had altered clinical management. Results. On CT, more than one location was involved in five patients (45 %) and in two patients (18 %) the entire pleural spaces were involved. Pleural thickening was seen in all 11 patients and enhancement after administration of contrast medium occurred in ten patients (91 %). Low-density fluid collections were seen in nine patients (82 %) and in two, CT revealed fluid collections within calcified pleural lesions. In five patients with mass-like lesions on plain radiographs, CT showed a low-density pleural mass with peripheral enhancement in four and a calcified pleural mass with fluid collection in one. CT demonstrated parenchymal abnormalities on the same side as pleural lesions in all 11 patients and hilar or mediastinal adenopathy in four. Four patients (36 %) underwent surgery because of fluid within a calcified fibrothorax (n = 3) and chest wall tuberculosis (n = 1) that were seen only on CT. Conclusions. The CT features of complicated pleural tuberculosis in children were pleural thickening, enhancement and fluid collection with associated parenchymal abnormalities and lymphadenopathy. In the evaluation of children with pleural tuberculosis, CT can be useful for demonstrating fluid within a calcified fibrothorax or chest wall involvement, which usually requires surgical intervention. (orig.)

  12. Clinical application of helical CT colonography

    International Nuclear Information System (INIS)

    Zeng Huiliang; Zhu Xinjin; Liang Rujian; Liang Jianhao; Ou Weiqian; Wen Haomao

    2009-01-01

    Objective: To investigate the clinical value of 16-slice helical CT colonography in the diagnosis of colon tumor and polypus. Methods: 16-slice helical CT volumetric scanning was performed in 18 patients with colonic disease, including colonic tumor (n=16) and colonic polypus (n=2). 3D images, virtual endoscopy and multiplanar reformation were obtained in the AW4.1 workstation. CT appearances were compared with operation and fiberoptic colonoscopy. Results: Satisfied results were achieved from 18 patients, no difference found in results between CT colonography and operation in 16 patients with colonic tumor. Conclusion: 16-slice helical CT colonography is of great value in preoperative staging of colonic tumor and have a high value in clinical application. (authors)

  13. CT diagnosis of retroperitoneal gigantic liposarcoma

    International Nuclear Information System (INIS)

    Fang Wei; Zheng Zhaohua; Liao Zuyuan; Hu Yinsong

    2009-01-01

    Objective: To analyze CT manifestation of retroperitoneal gigantic liposaxcoma and to improve the image understanding. Methods: Five cases of retroperitoneal gigantic liposarcoma confirmed by surgery and pathology in our hospital were collected. Plain and enhanced CT scan were performed. Results: Of five cases, one was substantive, two was pseudocyst and two was mixed tumor. Several patterns of enhancement such as strip, floccule, irregular patchy or nodular enhancement were revealed inside the lesions on enhanced CT scan. And strip-form of high density enhancement was a typical type. Conclusion: CT examination could determine the tumor's location, size and density, together with the relationship to adjacent organizations CT scan is an important method in diagnosing retroperitoneal gigantic liposarcoma. (authors)

  14. CT findings of early right colonic diverticulitis

    International Nuclear Information System (INIS)

    Lee, Jong Hwa; Ham, Su Yeon; Whang, Kang Ik

    1998-01-01

    The purpose of this study is to investigate the CT findings of acute right colonic diverticulitis, and to determine the difference between these and published reports describing left colonic, especially sigmoid, diverticulitis. Inflamed diverticula were visible in all cases, and were solitary. Nine cases occurred in the ascending colon and four in the cecum; in particular, eleven occurred around the ileocecal valve. In three cases, the inflamed diverticulum was less than 1 cm in diameter; in five cases, 1-2 cm; in three, 2-3 cm, and in two, 3-4 cm. These were able to be classified into two major forms. In three cases it was nodular with hyperattenuation and some inhomogeneity, and ten shows the target form with thick walls and a central cavity. In five of these target lesions, the wall pattern was partially or completely inhomogeneous, or multilayered. The material filling the central cavity were gas in five cases, fecalith in two, and fluid in three. Abnormal pericoloic fat infiltrations were seen in twelve cases (92%), segmental colonic wall thickening in eleven (85%), other not-inflamed diverticula in five (38%), mesenteric lymph node enlargement in three (23%), free pericecal fluid collection in three (23%), and perirenal fascial thickening in two (15%). The complications such as remote abscess cavity, colonic obstruction, fistula or perforation were not found. On barium colon study, diverticulitis was in all cases confirmed by the presence of barium in the deformed diversiculum. Among CT findings for acute right colonic diverticulitis, the most important and pathognomonic is inflamed diverticula; the forms of these vary, and include gangrenous diverticulitis. The CT findings of early right colonic diverticulitis in Koreans might not, however, reveal the complications which sigmoid diverticulitis frequently involves; in patients with right lower quadrant pain imaging studies are performed promptly, and for the mesentery, the anatomical base between right and

  15. Trapping volumetric measurement by multidetector CT in chronic obstructive pulmonary disease: Effect of CT threshold

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xiaohua; Yuan, Huishu [Department of Radiology, Peking University Third Hospital, Beijing 100191 (China); Duan, Jianghui [Medical School, Peking University, Beijing 100191 (China); Du, Yipeng; Shen, Ning; He, Bei [Department of Respiration Internal Medicine, Peking University Third Hospital, Beijing 100191 (China)

    2013-08-15

    Purpose: The purpose of this study was to evaluate the effect of various computed tomography (CT) thresholds on trapping volumetric measurements by multidetector CT in chronic obstructive pulmonary disease (COPD).Methods: Twenty-three COPD patients were scanned with a 64-slice CT scanner in both the inspiratory and expiratory phase. CT thresholds of −950 Hu in inspiration and −950 to −890 Hu in expiration were used, after which trapping volumetric measurements were made using computer software. Trapping volume percentage (Vtrap%) under the different CT thresholds in the expiratory phase and below −950 Hu in the inspiratory phase was compared and correlated with lung function.Results: Mean Vtrap% was similar under −930 Hu in the expiratory phase and below −950 Hu in the inspiratory phase, being 13.18 ± 9.66 and 13.95 ± 6.72 (both lungs), respectively; this difference was not significant (P= 0.240). Vtrap% under −950 Hu in the inspiratory phase and below the −950 to −890 Hu threshold in the expiratory phase was moderately negatively correlated with the ratio of forced expiratory volume in one second to forced vital capacity and the measured value of forced expiratory volume in one second as a percentage of the predicted value.Conclusions: Trapping volumetric measurement with multidetector CT is a promising method for the quantification of COPD. It is important to know the effect of various CT thresholds on trapping volumetric measurements.

  16. The effect of iodine uptake on radiation dose absorbed by patient tissues in contrast enhanced CT imaging. Implications for CT dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Perisinakis, Kostas; Damilakis, John [University of Crete, Department of Medical Physics, Medical School, Heraklion, Crete (Greece); University Hospital of Heraklion, Department of Medical Physics, Heraklion, Crete (Greece); Tzedakis, Antonis; Papadakis, Antonios E. [University Hospital of Heraklion, Department of Medical Physics, Heraklion, Crete (Greece); Spanakis, Kostas [University Hospital of Heraklion, Department of Radiology, Heraklion, Crete (Greece); Hatzidakis, Adam [University Hospital of Heraklion, Department of Radiology, Heraklion, Crete (Greece); University of Crete, Department of Radiology, Medical School, Heraklion, Crete (Greece)

    2018-01-15

    To investigate the effect of iodine uptake on tissue/organ absorbed doses from CT exposure and its implications in CT dosimetry. The contrast-induced CT number increase of several radiosensitive tissues was retrospectively determined in 120 CT examinations involving both non-enhanced and contrast-enhanced CT imaging. CT images of a phantom containing aqueous solutions of varying iodine concentration were obtained. Plots of the CT number increase against iodine concentration were produced. The clinically occurring iodine tissue uptake was quantified by attributing recorded CT number increase to a certain concentration of aqueous iodine solution. Clinically occurring iodine uptake was represented in mathematical anthropomorphic phantoms. Standard 120 kV CT exposures were simulated using Monte Carlo methods and resulting organ doses were derived for non-enhanced and iodine contrast-enhanced CT imaging. The mean iodine uptake range during contrast-enhanced CT imaging was found to be 0.02-0.46% w/w for the investigated tissues, while the maximum value recorded was 0.82% w/w. For the same CT exposure, iodinated tissues were found to receive higher radiation dose than non-iodinated tissues, with dose increase exceeding 100% for tissues with high iodine uptake. Administration of iodinated contrast medium considerably increases radiation dose to tissues from CT exposure. (orig.)

  17. CT of pleural abnormalities

    International Nuclear Information System (INIS)

    Webb, W.R.

    1995-01-01

    Briefly discussed were CT diagnosis of pleural thickening, CT technique for examining the pleura or pleuro-pulmonary disease, diagnosis of pleural collections, diagnosis of pleural fluid abnormalities in patients with pneumonia, pleural neoplasms, malignant (diffuse) mesothelioma, metastases, local fibrous tumor of the pleura (benign mesothelioma) (21 refs.)

  18. CT of pleural abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Webb, W R [California Univ., San Francisco, CA (United States). Dept. of Radiology

    1996-12-31

    Briefly discussed were CT diagnosis of pleural thickening, CT technique for examining the pleura or pleuro-pulmonary disease, diagnosis of pleural collections, diagnosis of pleural fluid abnormalities in patients with pneumonia, pleural neoplasms, malignant (diffuse) mesothelioma, metastases, local fibrous tumor of the pleura (benign mesothelioma) (21 refs.).

  19. Multiplanar CT of the spine

    International Nuclear Information System (INIS)

    Rothman, S.L.G.; Glenn, W.V. Jr.

    1986-01-01

    This is an illustrated text on computed tomography (CT) of the lumbar spine with an emphasis on the role and value of multiplanar imaging for helping determine diagnoses. The book has adequate discussion of scanning techniques for the different regions, interpretations of various abnormalities, degenerative disk disease, and different diagnoses. There is a 50-page chapter on detailed sectional anatomy of the spine and useful chapters on the postoperative spine and the planning and performing of spinal surgery with CT multiplanar reconstruction. There are comprehensive chapters on spinal tumors and trauma. The final two chapters of the book are devoted to CT image processing using digital networks and CT applications of medical computer graphics

  20. Left-right subtraction of brain CT

    International Nuclear Information System (INIS)

    Ishiguchi, Tsuneo; Sakuma, Sadayuki

    1986-01-01

    A new image-processing method to obtain a left-right subtraction image of CT was designed for the automated detection of abnormalities in brain CT. An original CT image was divided in two by a centerline. Then the right half of the image was subtracted from the left half by calculating the absorption value of the pixels on the symmetrical positions against the centerline. The mean and the standard deviation of the absorption value of the pixels in the subtraction image were used as parameters for analysis, and the detectability of abnormal CT findings was evaluated in 100 cases - 50 cases each with normal and abnormal CT. The presence of abnormalities could be diagnosed with a sensitivity of 86 %, a specificity of 90 %, and an overall accuracy of 88 % when the borderline of these parameters between normal and abnormal CT was set at the mean + 2SD in the normal group. As a further analysis, the CT image was subdivided into several areas from a functional or anatomical viewpoint, such as cerebral vascular territories, and the left-right subtraction image of each area was obtained. The possibilities of diagnosing the location of an abnormality and of detecting smaller lesions with this method were shown. Left-right subtraction was considered to be a useful method for the detection of asymmetric abnormalities in the automated diagnosis of brain CT. (author)

  1. Reassessment of CT images to improve diagnostic accuracy in patients with suspected acute appendicitis and an equivocal preoperative CT interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Cheol; Yang, Dal Mo; Kim, Sang Won [Kyung Hee University Hospital at Gangdong, College of Medicine, Kyung Hee University, Department of Radiology, Seoul (Korea, Republic of); Park, Seong Jin [Kyung Hee University Hospital, College of Medicine, Kyung Hee University, Department of Radiology, Seoul (Korea, Republic of)

    2012-06-15

    To identify CT features that discriminate individuals with and without acute appendicitis in patients with equivocal CT findings, and to assess whether knowledge of these findings improves diagnostic accuracy. 53 patients that underwent appendectomy with an indeterminate preoperative CT interpretation were selected and allocated to an acute appendicitis group or a non-appendicitis group. The 53 CT examinations were reviewed by two radiologists in consensus to identify CT findings that could aid in the discrimination of those with and without appendicitis. In addition, two additional radiologists were then requested to evaluate independently the 53 CT examinations using a 4-point scale, both before and after being informed of the potentially discriminating criteria. CT findings found to be significantly different in the two groups were; the presence of appendiceal wall enhancement, intraluminal air in appendix, a coexistent inflammatory lesion, and appendiceal wall thickening (P < 0.05). Areas under the curves of reviewers 1 and 2 significantly increased from 0.516 and 0.706 to 0.677 and 0.841, respectively, when reviewers were told which CT variables were significant (P = 0.0193 and P = 0.0397, respectively). Knowledge of the identified CT findings was found to improve diagnostic accuracy for acute appendicitis in patients with equivocal CT findings. circle Numerous patients with clinically equivocal appendicitis do not have acute appendicitis circle Computed tomography (CT) helps to reduce the negative appendectomy rate circle CT is not always infallible and may also demonstrate indeterminate findings circle However knowledge of significant CT variables can further reduce negative appendectomy rate circle An equivocal CT interpretation of appendicitis should be reassessed with this knowledge. (orig.)

  2. Reassessment of CT images to improve diagnostic accuracy in patients with suspected acute appendicitis and an equivocal preoperative CT interpretation

    International Nuclear Information System (INIS)

    Kim, Hyun Cheol; Yang, Dal Mo; Kim, Sang Won; Park, Seong Jin

    2012-01-01

    To identify CT features that discriminate individuals with and without acute appendicitis in patients with equivocal CT findings, and to assess whether knowledge of these findings improves diagnostic accuracy. 53 patients that underwent appendectomy with an indeterminate preoperative CT interpretation were selected and allocated to an acute appendicitis group or a non-appendicitis group. The 53 CT examinations were reviewed by two radiologists in consensus to identify CT findings that could aid in the discrimination of those with and without appendicitis. In addition, two additional radiologists were then requested to evaluate independently the 53 CT examinations using a 4-point scale, both before and after being informed of the potentially discriminating criteria. CT findings found to be significantly different in the two groups were; the presence of appendiceal wall enhancement, intraluminal air in appendix, a coexistent inflammatory lesion, and appendiceal wall thickening (P < 0.05). Areas under the curves of reviewers 1 and 2 significantly increased from 0.516 and 0.706 to 0.677 and 0.841, respectively, when reviewers were told which CT variables were significant (P = 0.0193 and P = 0.0397, respectively). Knowledge of the identified CT findings was found to improve diagnostic accuracy for acute appendicitis in patients with equivocal CT findings. circle Numerous patients with clinically equivocal appendicitis do not have acute appendicitis circle Computed tomography (CT) helps to reduce the negative appendectomy rate circle CT is not always infallible and may also demonstrate indeterminate findings circle However knowledge of significant CT variables can further reduce negative appendectomy rate circle An equivocal CT interpretation of appendicitis should be reassessed with this knowledge. (orig.)

  3. Spect-CT and PET: CT in the management of differentiated thyroid cancer

    International Nuclear Information System (INIS)

    Khan, Shoukat H.

    2007-01-01

    Full text: With the advancement and evolution in medical technology notably imaging there has been a sea change in the overall management strategy of most of the cancers of human body. The present day functional, imaging with PET and MRI enables us to pick up a tumour at its cellular stage. Molecular imaging and nanotechnology have further added to this expanding armamentarium of cancer imaging and treatment. Thyroid cancer is one such cancer where the cutting edge biotechnology has dramatically changed the management profile of a disease. Thyroid cancer can safely be classified as one of the cancers which if optimally managed is curable. Hybrid and fusion imaging like SPECT-CT and PET-CT with their superior sensitivity and specificity have greatly improved the accuracy of disease detection and reduced drastically the false positive disease sites. Disease not detected by conventional planar imaging can now be detected and also anatomically localized using hybrid imaging modalities of SPECT-CT and PET-CT. An accurate detection and precise localization improves image interpretation and a treatment optimization in the curable cancer of thyroid

  4. Comparison of CT and integrated PET-CT based radiation therapy planning in patients with malignant pleural mesothelioma

    International Nuclear Information System (INIS)

    Pehlivan, Berrin; Topkan, Erkan; Onal, Cem; Nursal, Gul Nihal; Yuksel, Oznur; Dolek, Yemliha; Yavuz, Melek Nur; Yavuz, Ali Aydin

    2009-01-01

    When combined with adequate tumoricidal doses, accurate target volume delineation remains to be the one of the most important predictive factors for radiotherapy (RT) success in locally advanced or medically inoperable malignant pleural mesothelioma (MPM) patients. Recently, 18-fluorodeoxyglucose positron emission tomography (PET) has demonstrated significant improvements in diagnosis and accurate staging of MPM. However, role of additional PET data has not been studied in RT planning (RTP) of patients with inoperable MPM or in those who refuse surgery. Therefore, we planned to compare CT with co-registered PET-CT as the basis for delineating target volumes in these patients group. Retrospectively, the CT and co-registered PET-CT data of 13 patients with histologically proven MPM were utilized to delineate target volumes separately. For each patient, target volumes (gross tumor volume [GTV], clinical target volume [CTV], and planning target volume [PTV]) were defined using the CT and PET-CT fusion data sets. The PTV was measured in two ways: PTV1 was CTV plus a 1-cm margin, and PTV2 was GTV plus a 1-cm margin. We analyzed differences in target volumes. In 12 of 13 patients, compared to CT-based delineation, PET-CT-based delineation resulted in a statistically significant decrease in the mean GTV, CTV, PTV1, and PTV2. In these 12 patients, mean GTV decreased by 47.1% ± 28.4%, mean CTV decreased by 38.7% ± 24.7%, mean PTV1 decreased by 31.1% ± 23.1%, and mean PTV2 decreased by 40.0% ± 24.0%. In 4 of 13 patients, hilar lymph nodes were identified by PET-CT that was not identified by CT alone, changing the nodal status of tumor staging in those patients. This study demonstrated the usefulness of PET-CT-based target volume delineation in patients with MPM. Co-registration of PET and CT information reduces the likelihood of geographic misses, and additionally, significant reductions observed in target volumes may potentially allow escalation of RT dose beyond

  5. CT Diagnosis of Appendicitis

    Directory of Open Access Journals (Sweden)

    Christopher Libby

    2017-01-01

    Full Text Available History of present illness: A 19-year-old male with no previous medical history presented with 7/10 non-radiating, constant, sharp, periumbilical pain associated with nausea, and four episodes of vomiting. He was seen at urgent care where his labs showed a WBC of 16,000/mcL. He was subsequently sent to the emergency department (ED for concern of appendicitis. Of note, his pain worsened with bumps during the drive to the ED. After arriving to the ED the pain migrated to the right lower quadrant. Computed tomography (CT revealed acute appendicitis and the patient was admitted to the surgery service and taken to the operating room (OR for an appendectomy. Significant findings: The CT abdomen/pelvis with IV contrast shows a dilated appendix (see red outline with thickened, hyperenhancing wall (see blue outline best visualized in the axial and coronal planes. Discussion: Appendicitis is a common diagnosis in the emergency department in patients presenting with abdominal pain, occurring most frequently in young adults with a peak incidence in those aged 10-19.1 Failure to quickly diagnose acute appendicitis can result in perforation rates as high as 80 percent.2 While the diagnosis of appendicitis can be made clinically, CT is a non-invasive modality that improves the detection of appendicitis with sensitivities of 88–100%, specificities of 91–99%, positive predictive values of 92–98%, negative predictive values of 95–100%, and accuracies of 94–98%.3-8 The major advantage of CT over both clinical exam and ultrasound is the ability of the radiologist to exclude acute appendicitis if the appendix appears normal. However, CT carries the risks associated with ionizing radiation. While previously there was some debate on the best choice for type of CT scan and use of IV and oral contrast, recent studies have shown that CT abdomen/pelvis with IV contrast alone is sufficient for diagnosis of appendicitis.9, 10

  6. CT examinations in older patients

    International Nuclear Information System (INIS)

    Sciuk, J.; Peters, P.E.

    1989-01-01

    A total of 2,878 unselected subsequent CT examinations carried out in 1984 were analyzed retrospectively. All studies were performed in a university hospital with a centralized department of diagnostic radiology. Most of the patients investigated were hospitalized; there were only 12% outpatients. Of the patients studied 12.6% were older than 65 years and 20.5% older than 60; 17.7% were emergency cases and patients between 16 and 25 years of age represented the largest fraction. In all other age groups the relative distribution between emergency cases and regular studies revealed no significant differences. There was no statistically significant difference between the older age group (patients older than 65 years) and the total population of this study in almost all items investigated, i.e., no differences in CT examination time and no differences in preparation time (time between two CT studies). The rate of abdominal CT examinations was 7% higher in the older age group, while the relative distribution of all other CT examinations was again comparable to the total population under study. Thus, the expected increase in patients in the older age group does not measurably prolong the CT examination time. This statement applies to a major referral center with a high percentage of inpatients. (orig.) [de

  7. Overview of CT technologies for children

    Energy Technology Data Exchange (ETDEWEB)

    Frush, Donald P. [Duke University Medical Center, Department of Radiology, Box 3808, Durham, NC (United States)

    2014-10-15

    Many technical advances in CT have reduced radiation exposure in children and adults. These advances in technology should be used in conjunction with CT techniques such as appropriate patient preparation and intravenous contrast media administration to maximize dose management and image quality. This article summarizes current dose reduction technologies for pediatric CT, noting ranges of dose reduction as well as potential limitations. Discussion includes some of the elusive aspects of assessing image quality and the need for developing personalized CT. (orig.)

  8. Overview of CT technologies for children

    International Nuclear Information System (INIS)

    Frush, Donald P.

    2014-01-01

    Many technical advances in CT have reduced radiation exposure in children and adults. These advances in technology should be used in conjunction with CT techniques such as appropriate patient preparation and intravenous contrast media administration to maximize dose management and image quality. This article summarizes current dose reduction technologies for pediatric CT, noting ranges of dose reduction as well as potential limitations. Discussion includes some of the elusive aspects of assessing image quality and the need for developing personalized CT. (orig.)

  9. CT-diskography in patients with sciatica. Comparison with plain CT and MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Dullerud, R. [Ullevaal Univ. Hospital, Oslo (Norway). Section of Neuroradiology; Johansen, J.G. [Ullevaal Univ. Hospital, Oslo (Norway). Section of Neuroradiology

    1995-09-01

    The findings at CT-diskography (CT-D), including recording of the pain introduced at contrast injection, were compared with plain CT and MR imaging in 111 disks in 101 patients aged 18 to 68 years. Six disks which were normal at CT had normal CT-D and 5 of them had normal signal on MR imaging. The degree of annular degeneration and the depth of the annular tears were significantly associated with each other and with loss of disk height, but not with size or location of the hernias. Only the depth of the tears was significantly associated with loss of signal on MR. However, frequently complete annular tears and severe annular degeneration were seen in association with small bulges and hernias, even in disks with normal or slightly reduced signal on MR and with normal height. The type and intensity of the pain introduced were associated with each other and with the depth of the annular tears, but not with the degree of annular degeneration, size of the hernia or the MR signal intensity of the disks. Annular degeneration and tears on one hand, and the type and intensity of pain introduced on the other, see to be related rather than separate phenomena. (orig./MG).

  10. CT-diskography in patients with sciatica. Comparison with plain CT and MR imaging

    International Nuclear Information System (INIS)

    Dullerud, R.; Johansen, J.G.

    1995-01-01

    The findings at CT-diskography (CT-D), including recording of the pain introduced at contrast injection, were compared with plain CT and MR imaging in 111 disks in 101 patients aged 18 to 68 years. Six disks which were normal at CT had normal CT-D and 5 of them had normal signal on MR imaging. The degree of annular degeneration and the depth of the annular tears were significantly associated with each other and with loss of disk height, but not with size or location of the hernias. Only the depth of the tears was significantly associated with loss of signal on MR. However, frequently complete annular tears and severe annular degeneration were seen in association with small bulges and hernias, even in disks with normal or slightly reduced signal on MR and with normal height. The type and intensity of the pain introduced were associated with each other and with the depth of the annular tears, but not with the degree of annular degeneration, size of the hernia or the MR signal intensity of the disks. Annular degeneration and tears on one hand, and the type and intensity of pain introduced on the other, see to be related rather than separate phenomena. (orig./MG)

  11. PET/CT in malignant melanoma: contrast-enhanced CT versus plain low-dose CT

    International Nuclear Information System (INIS)

    Pfluger, Thomas; Schneider, Vera; Fougere, Christian la; Bartenstein, Peter; Weiss, Mayo; Melzer, Henriette Ingrid; Coppenrath, Eva; Berking, Carola

    2011-01-01

    The aim of this study was to evaluate the diagnostic value of contrast-enhanced CT (CECT) versus non-enhanced low-dose CT (NECT) in the staging of advanced malignant melanoma with 18 F-fluordeoxyglucose (FDG) positron emission tomography (PET)/CT. In total, 50 18 F-FDG PET/CT examinations were performed in 50 patients with metastasized melanoma. For attenuation correction, whole-body NECT was performed followed by diagnostic CECT with contrast agent. For the whole-body PET, 18 F-FDG was applied. Criteria for evaluation were signs of vital tumour tissue (extent of lesions, contrast enhancement, maximum standardized uptake value >2.5). Findings suspicious for melanoma were considered lesions. NECT, CECT and 18 F-FDG PET were evaluated separately, followed by combined analysis of PET/NECT and PET/CECT. Findings were verified histologically and/or by follow-up (>6 months). Overall, 232 lesions were analysed, and 151 proved to be metastases. The sensitivity of NECT, CECT, PET, PET/NECT and PET/CECT was 62, 85, 90, 97 and 100%, and specificity was 52, 63, 88, 93 and 93%, respectively. Compared to CECT, NECT obtained additional false-negative results: lymph node (n = 19) and liver/spleen metastases (n = 9). Misinterpreted physiological structures mainly caused additional false-positive findings (n = 17). In combined analysis of PET/NECT, six false-positive [other tumours (n = 2), inflammatory lymph nodes (n = 2), inflammatory lung lesion (n = 1), blood vessel (n = 1)] and five false-negative findings [liver (n = 3), spleen (n = 1), lymph node metastases (n = 1)] remained. On PET/CECT, six false-positive [inflammatory lymph nodes (n = 3), other tumours (n = 2), inflammatory lung lesion (n = 1)] and no false-negative findings occurred. However, additional false findings on PET/NECT (6 of 232) did not change staging compared to PET/CECT. Our results indicate that it is justified to perform PET/NECT instead of PET/CECT for melanoma staging. (orig.)

  12. Diagnostic performance of contrast enhanced CT and 18F-FDG PET/CT in suspicious recurrence of biliary tract cancer after curative resection

    International Nuclear Information System (INIS)

    Lee, Yun-Gyoo; Bang, Yung-Jue; Han, Sae-Won; Oh, Do-Youn; Chie, Eui Kyu; Jang, Jin-Young; Im, Seock-Ah; Kim, Tae-You; Kim, Sun-Whe; Ha, Sung Whan

    2011-01-01

    Because of the late clinical presentation of biliary tract cancer (BTC), only 10% of patients are eligible for curative surgery. Even among those patients who have undergone curative surgery, most patients develop recurrent cancer. This study is to determine the clinical role of 18 F-FDG PET/CT during post-operative surveillance of suspected recurrent BTC based on symptoms, laboratory findings and contrast-enhanced CT (ceCT) findings. We consecutively enrolled 50 patients with BTC who underwent curative surgery. An 18 F-FDG PET/CT was obtained for assessment of recurrence based on clinical suspicion during post-operative surveillance. The final confirmation of recurrence was determined pathologically or clinically. When a pathologic confirmation was impossible or inconclusive, a clinical confirmation was used by radiologic correlation with subsequent follow-up ceCT at a minimum of 3-month intervals. Diagnostic efficacy was evaluated by comparing the results of ceCT and 18 F-FDG PET/CT with the final diagnosis. Among the 50 patients, 34(68%) were confirmed to have a recurrence. PET/CT showed higher sensitivity (88% vs. 76%, p = 0.16) and accuracy (82% vs. 66%, p = 0.11) for recurrence compared to ceCT, even though the difference was not significant. The positive (86% vs. 74%, p = 0.72) and negative predictive values for recurrence (73% vs. 47%, p = 0.55) were not significantly different between PET/CT and ceCT. However, an additional PET/CT on ceCT significantly improved the sensitivity than did a ceCT alone (94% [32/34] for PET/CT on ceCT vs. 76% [26/34] for ceCT alone, p = 0.03) without increasing the specificity, positive predictive value, and negative predictive value. 18 F-FDG PET/CT alone is not more sensitive or specific than ceCT in the detection of recurrent BTC after curative surgery. These results do not reach statistical significance, probably due to the low number of patients. However, an additional 18 F-FDG PET/CT on ceCT significantly improves the

  13. Predicting tumor hypoxia in non-small cell lung cancer by combining CT, FDG PET and dynamic contrast-enhanced CT.

    Science.gov (United States)

    Even, Aniek J G; Reymen, Bart; La Fontaine, Matthew D; Das, Marco; Jochems, Arthur; Mottaghy, Felix M; Belderbos, José S A; De Ruysscher, Dirk; Lambin, Philippe; van Elmpt, Wouter

    2017-11-01

    Most solid tumors contain inadequately oxygenated (i.e., hypoxic) regions, which tend to be more aggressive and treatment resistant. Hypoxia PET allows visualization of hypoxia and may enable treatment adaptation. However, hypoxia PET imaging is expensive, time-consuming and not widely available. We aimed to predict hypoxia levels in non-small cell lung cancer (NSCLC) using more easily available imaging modalities: FDG-PET/CT and dynamic contrast-enhanced CT (DCE-CT). For 34 NSCLC patients, included in two clinical trials, hypoxia HX4-PET/CT, planning FDG-PET/CT and DCE-CT scans were acquired before radiotherapy. Scans were non-rigidly registered to the planning CT. Tumor blood flow (BF) and blood volume (BV) were calculated by kinetic analysis of DCE-CT images. Within the gross tumor volume, independent clusters, i.e., supervoxels, were created based on FDG-PET/CT. For each supervoxel, tumor-to-background ratios (TBR) were calculated (median SUV/aorta SUV mean ) for HX4-PET/CT and supervoxel features (median, SD, entropy) for the other modalities. Two random forest models (cross-validated: 10 folds, five repeats) were trained to predict the hypoxia TBR; one based on CT, FDG, BF and BV, and one with only CT and FDG features. Patients were split in a training (trial NCT01024829) and independent test set (trial NCT01210378). For each patient, predicted, and observed hypoxic volumes (HV) (TBR > 1.2) were compared. Fifteen patients (3291 supervoxels) were used for training and 19 patients (1502 supervoxels) for testing. The model with all features (RMSE training: 0.19 ± 0.01, test: 0.27) outperformed the model with only CT and FDG-PET features (RMSE training: 0.20 ± 0.01, test: 0.29). All tumors of the test set were correctly classified as normoxic or hypoxic (HV > 1 cm 3 ) by the best performing model. We created a data-driven methodology to predict hypoxia levels and hypoxia spatial patterns using CT, FDG-PET and DCE-CT features in NSCLC. The

  14. Virtual Non-Contrast CT Using Dual-Energy Spectral CT: Feasibility of Coronary Artery Calcium Scoring

    OpenAIRE

    Song, Inyoung; Yi, Jeong Geun; Park, Jeong Hee; Kim, Sung Mok; Lee, Kyung Soo; Chung, Myung Jin

    2016-01-01

    Objective To evaluate the feasibility of coronary artery calcium scoring based on three virtual noncontrast-enhanced (VNC) images derived from single-source spectral dual-energy CT (DECT) as compared with true noncontrast-enhanced (TNC) images. Materials and Methods This prospective study was conducted with the approval of our Institutional Review Board. Ninety-seven patients underwent noncontrast CT followed by contrast-enhanced chest CT using single-source spectral DECT. Iodine eliminated V...

  15. CT applications of medical computer graphics

    International Nuclear Information System (INIS)

    Rhodes, M.L.

    1985-01-01

    Few applications of computer graphics show as much promise and early success as that for CT. Unlike electron microscopy, ultrasound, business, military, and animation applications, CT image data are inherently digital. CT pictures can be processed directly by programs well established in the fields of computer graphics and digital image processing. Methods for reformatting digital pictures, enhancing structure shape, reducing image noise, and rendering three-dimensional (3D) scenes of anatomic structures have all become routine at many CT centers. In this chapter, the authors provide a brief introduction to computer graphics terms and techniques commonly applied to CT pictures and, when appropriate, to those showing promise for magnetic resonance images. Topics discussed here are image-processing options that are applied to digital images already constructed. In the final portion of this chapter techniques for ''slicing'' CT image data are presented, and geometric principles that describe the specification of oblique and curved images are outlined. Clinical examples are included

  16. CT images of infantile viral encephalitis

    International Nuclear Information System (INIS)

    Sugimoto, Tateo; Okazaki, Hitoshi; Woo, Man

    1985-01-01

    Cranial CT scanning was undertaken in 40 patients with infantile viral encephalitis seen from 1977 to 1983. According to the pathogenic viruses, abnormal CT findings were detected most frequently in cases of herpes simplex encephalitis (HSE), followed by non-eruptive viral encephalitis, measles encephalitis, and rubella encephalitis in that order, which coincided well with neurological prognosis. Although CT findings lay within a normal range in cases of measles encephalitis, except a case in which cerebral ventricle was slightly dilated, the degree of consciousness disturbance was unfavorable and it persisted long. This revealed that there is no distinct correlation between the degree of consciousness disturbance and CT findings. Normal CT findings were detected in 13% of patients aged less than 5 years and 76.5% of patients aged 5 years or more. In many patients who had an attack of viral encephalitis at the age of 5 years or more, epileptic seizures occurred frequently, even though CT findings were normal. (Namekawa, K.)

  17. MR and CT for malignant hypernephromas

    International Nuclear Information System (INIS)

    Uhlenbrock, D.; Fischer, C.; Ruehl, G.; Beyer, H.K.; Hummelsheim, P.; Bochum Univ.; Marienhospital, Herne; Bochum Univ.

    1987-01-01

    Forty patients with histologically confirmed hypernephromas were examined by MR and CT. As regards T-staging, MR had an accuracy of 97 % and CT of 91%; for N-staging, MR had an accuracy of 85% and CT of 91% and, with regard to infiltration of the renal vein, MR was correct in 88% of cases and CT in 81%. MR was most accurate in the pre-operative assessment of tumour spread, demonstrating caval involvement in 100% and lymph node metastases in 97%. On the other hand, infiltration of the renal pelvis could be assessed in only 65% of cases; in 27% the assessment was not possible and in 8% one could not be certain. CT proved to be at its best for staging of lymph nodes, but in 15% it was not possible to identify infiltration of the renal vein. MR was not greatly superior to CT in the preoperative diagnosis and staging of hypernephromas. (orig.) [de

  18. Radiation dose reduction through combining positron emission tomography/computed tomography (PET/CT) and diagnostic CT in children and young adults with lymphoma

    International Nuclear Information System (INIS)

    Qi, Zhihua; Gates, Erica L.; Trout, Andrew T.; O'Brien, Maureen M.

    2018-01-01

    Both [F-18]2-fluoro-2-deoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT) and diagnostic CT are at times required for lymphoma staging. This means some body segments are exposed twice to X-rays for generation of CT data (diagnostic CT + localization CT). To describe a combined PET/diagnostic CT approach that modulates CT tube current along the z-axis, providing diagnostic CT of some body segments and localization CT of the remaining body segments, thereby reducing patient radiation dose. We retrospectively compared total patient radiation dose between combined PET/diagnostic CT and separately acquired PET/CT and diagnostic CT exams. When available, we calculated effective doses for both approaches in the same patient; otherwise, we used data from patients of similar size. To confirm image quality, we compared image noise (Hounsfield unit [HU] standard deviation) as measured in the liver on both combined and separately acquired diagnostic CT images. We used t-tests for dose comparisons and two one-sided tests for image-quality equivalence testing. Mean total effective dose for the CT component of the combined and separately acquired diagnostic CT exams were 6.20±2.69 and 8.17±2.61 mSv, respectively (P<0.0001). Average dose savings with the combined approach was 24.8±17.8% (2.60±2.51 mSv [range: 0.32-4.72 mSv]) of total CT effective dose. Image noise was not statistically significantly different between approaches (12.2±1.8 HU vs. 11.7±1.5 HU for the combined and separately acquired diagnostic CT images, respectively). A combined PET/diagnostic CT approach as described offers dose savings at similar image quality for children and young adults with lymphoma who have indications for both PET and diagnostic CT examinations. (orig.)

  19. Radiation dose reduction through combining positron emission tomography/computed tomography (PET/CT) and diagnostic CT in children and young adults with lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Qi, Zhihua; Gates, Erica L.; Trout, Andrew T. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); O' Brien, Maureen M. [Cincinnati Children' s Hospital Medical Center, Division of Oncology, Cancer and Blood Disease Institute, Cincinnati, OH (United States)

    2018-02-15

    Both [F-18]2-fluoro-2-deoxyglucose positron emission tomography/computed tomography ({sup 18}F-FDG PET/CT) and diagnostic CT are at times required for lymphoma staging. This means some body segments are exposed twice to X-rays for generation of CT data (diagnostic CT + localization CT). To describe a combined PET/diagnostic CT approach that modulates CT tube current along the z-axis, providing diagnostic CT of some body segments and localization CT of the remaining body segments, thereby reducing patient radiation dose. We retrospectively compared total patient radiation dose between combined PET/diagnostic CT and separately acquired PET/CT and diagnostic CT exams. When available, we calculated effective doses for both approaches in the same patient; otherwise, we used data from patients of similar size. To confirm image quality, we compared image noise (Hounsfield unit [HU] standard deviation) as measured in the liver on both combined and separately acquired diagnostic CT images. We used t-tests for dose comparisons and two one-sided tests for image-quality equivalence testing. Mean total effective dose for the CT component of the combined and separately acquired diagnostic CT exams were 6.20±2.69 and 8.17±2.61 mSv, respectively (P<0.0001). Average dose savings with the combined approach was 24.8±17.8% (2.60±2.51 mSv [range: 0.32-4.72 mSv]) of total CT effective dose. Image noise was not statistically significantly different between approaches (12.2±1.8 HU vs. 11.7±1.5 HU for the combined and separately acquired diagnostic CT images, respectively). A combined PET/diagnostic CT approach as described offers dose savings at similar image quality for children and young adults with lymphoma who have indications for both PET and diagnostic CT examinations. (orig.)

  20. Radiation dose reduction through combining positron emission tomography/computed tomography (PET/CT) and diagnostic CT in children and young adults with lymphoma.

    Science.gov (United States)

    Qi, Zhihua; Gates, Erica L; O'Brien, Maureen M; Trout, Andrew T

    2018-02-01

    Both [F-18]2-fluoro-2-deoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT) and diagnostic CT are at times required for lymphoma staging. This means some body segments are exposed twice to X-rays for generation of CT data (diagnostic CT + localization CT). To describe a combined PET/diagnostic CT approach that modulates CT tube current along the z-axis, providing diagnostic CT of some body segments and localization CT of the remaining body segments, thereby reducing patient radiation dose. We retrospectively compared total patient radiation dose between combined PET/diagnostic CT and separately acquired PET/CT and diagnostic CT exams. When available, we calculated effective doses for both approaches in the same patient; otherwise, we used data from patients of similar size. To confirm image quality, we compared image noise (Hounsfield unit [HU] standard deviation) as measured in the liver on both combined and separately acquired diagnostic CT images. We used t-tests for dose comparisons and two one-sided tests for image-quality equivalence testing. Mean total effective dose for the CT component of the combined and separately acquired diagnostic CT exams were 6.20±2.69 and 8.17±2.61 mSv, respectively (PCT effective dose. Image noise was not statistically significantly different between approaches (12.2±1.8 HU vs. 11.7±1.5 HU for the combined and separately acquired diagnostic CT images, respectively). A combined PET/diagnostic CT approach as described offers dose savings at similar image quality for children and young adults with lymphoma who have indications for both PET and diagnostic CT examinations.

  1. Panoramic three-dimensional CT imaging

    International Nuclear Information System (INIS)

    Kawamata, Akitoshi; Fujishita, Masami

    1998-01-01

    Panoramic radiography is a unique projection technique for producing a single image of both maxillary and mandibular arches and many other anatomical structures. To obtain a similar panoramic image without panoramic radiography system, a modified three-dimensional (3D) CT imaging technique was designed. A set of CT slice image data extending from the chin to the orbit was used for 3D reconstruction. The CT machine used in this study was the X-Vision (TOSHIBA, Japan). The helical scan technique was used. The slice thickness of reconstructed image was one or 1.5 mm. The occlusal plane or Frankfort horizontal (FH) plane was used as the reference line. The resultant slice image data was stored on a magnetic optical disk and then used to create panoramic 3D-CT images on a Macintosh computer systems (Power Macintosh 8600/250, Apple Computer Inc., USA). To create the panoramic 3D-CT image, the following procedure was designed: Design a curved panoramic 3D-CT imaging layer using the imaging layer and the movement of the x-ray beam in panoramic radiography system as a template; Cut this imaging layer from each slice image, then the trimmed image was transformed to a rectangular layer using the ''still image warping'' special effect in the Elastic Reality special effects system (Elastic Reality Inc., USA); Create panoramic 3D-CT image using the Voxel View (Vital Images Inc., USA) rendering system and volume rendering technique. Although the image quality was primitive, a panoramic view of maxillofacial region was obtained by this technique. (author)

  2. Use of the CT component of PET-CT to improve PET-MR registration: demonstration in soft-tissue sarcoma

    International Nuclear Information System (INIS)

    Somer, Edward J; Benatar, Nigel A; O'Doherty, Michael J; Smith, Mike A; Marsden, Paul K

    2007-01-01

    We have investigated improvements to PET-MR image registration offered by PET-CT scanning. Ten subjects with suspected soft-tissue sarcomas were scanned with an in-line PET-CT and a clinical MR scanner. PET to CT, CT to MR and PET to MR image registrations were performed using a rigid-body external marker technique and rigid and non-rigid voxel-similarity algorithms. PET-MR registration was also performed using transformations derived from the registration of CT to MR. The external marker technique gave fiducial registration errors of 2.1 mm, 5.1 mm and 5.3 mm for PET-CT, PET-MR and CT-MR registration. Target registration errors were 3.9 mm, 9.0 mm and 9.3 mm, respectively. Voxel-based algorithms were evaluated by measuring the distance between corresponding fiducials after registration. Registration errors of 6.4 mm, 14.5 mm and 9.5 mm, respectively, for PET-CT, PET-MR and CT-MR were observed for rigid-body registration while non-rigid registration gave errors of 6.8 mm, 16.3 mm and 7.6 mm for the same modality combinations. The application of rigid and non-rigid CT to MR transformations to accompanying PET data gives significantly reduced PET-MR errors of 10.0 mm and 8.5 mm, respectively. Visual comparison by two independent observers confirmed the improvement over direct PET-MR registration. We conclude that PET-MR registration can be more accurately and reliably achieved using the hybrid technique described than through direct rigid-body registration of PET to MR

  3. Chest CT in children: anesthesia and atelectasis

    Energy Technology Data Exchange (ETDEWEB)

    Newman, Beverley; Gawande, Rakhee [Lucile Packard Children' s Hospital, Department of Radiology, Stanford, CA (United States); Krane, Elliot J. [Stanford University School of Medicine, Lucile Packard Children' s Hospital, Department of Anesthesiology, Perioperative and Pain Medicine, Stanford, CA (United States); Holmes, Tyson H. [Stanford University School of Medicine, Lucile Packard Children' s Hospital, Department of Psychiatry and Behavioral Sciences, Stanford, CA (United States); Robinson, Terry E. [Stanford University School of Medicine, Lucile Packard Children' s Hospital, Department of Pulmonary Medicine and Cystic Fibrosis Center for Excellence in Pulmonary Biology, Stanford, CA (United States)

    2014-02-15

    There has been an increasing tendency for anesthesiologists to be responsible for providing sedation or anesthesia during chest CT imaging in young children. Anesthesia-related atelectasis noted on chest CT imaging has proven to be a common and troublesome problem, affecting image quality and diagnostic sensitivity. To evaluate the safety and effectiveness of a standardized anesthesia, lung recruitment, controlled-ventilation technique developed at our institution to prevent atelectasis for chest CT imaging in young children. Fifty-six chest CT scans were obtained in 42 children using a research-based intubation, lung recruitment and controlled-ventilation CT scanning protocol. These studies were compared with 70 non-protocolized chest CT scans under anesthesia taken from 18 of the same children, who were tested at different times, without the specific lung recruitment and controlled-ventilation technique. Two radiology readers scored all inspiratory chest CT scans for overall CT quality and atelectasis. Detailed cardiorespiratory parameters were evaluated at baseline, and during recruitment and inspiratory imaging on 21 controlled-ventilation cases and 8 control cases. Significant differences were noted between groups for both quality and atelectasis scores with optimal scoring demonstrated in the controlled-ventilation cases where 70% were rated very good to excellent quality scans compared with only 24% of non-protocol cases. There was no or minimal atelectasis in 48% of the controlled ventilation cases compared to 51% of non-protocol cases with segmental, multisegmental or lobar atelectasis present. No significant difference in cardiorespiratory parameters was found between controlled ventilation and other chest CT cases and no procedure-related adverse events occurred. Controlled-ventilation infant CT scanning under general anesthesia, utilizing intubation and recruitment maneuvers followed by chest CT scans, appears to be a safe and effective method to obtain

  4. Chest CT in children: anesthesia and atelectasis

    International Nuclear Information System (INIS)

    Newman, Beverley; Gawande, Rakhee; Krane, Elliot J.; Holmes, Tyson H.; Robinson, Terry E.

    2014-01-01

    There has been an increasing tendency for anesthesiologists to be responsible for providing sedation or anesthesia during chest CT imaging in young children. Anesthesia-related atelectasis noted on chest CT imaging has proven to be a common and troublesome problem, affecting image quality and diagnostic sensitivity. To evaluate the safety and effectiveness of a standardized anesthesia, lung recruitment, controlled-ventilation technique developed at our institution to prevent atelectasis for chest CT imaging in young children. Fifty-six chest CT scans were obtained in 42 children using a research-based intubation, lung recruitment and controlled-ventilation CT scanning protocol. These studies were compared with 70 non-protocolized chest CT scans under anesthesia taken from 18 of the same children, who were tested at different times, without the specific lung recruitment and controlled-ventilation technique. Two radiology readers scored all inspiratory chest CT scans for overall CT quality and atelectasis. Detailed cardiorespiratory parameters were evaluated at baseline, and during recruitment and inspiratory imaging on 21 controlled-ventilation cases and 8 control cases. Significant differences were noted between groups for both quality and atelectasis scores with optimal scoring demonstrated in the controlled-ventilation cases where 70% were rated very good to excellent quality scans compared with only 24% of non-protocol cases. There was no or minimal atelectasis in 48% of the controlled ventilation cases compared to 51% of non-protocol cases with segmental, multisegmental or lobar atelectasis present. No significant difference in cardiorespiratory parameters was found between controlled ventilation and other chest CT cases and no procedure-related adverse events occurred. Controlled-ventilation infant CT scanning under general anesthesia, utilizing intubation and recruitment maneuvers followed by chest CT scans, appears to be a safe and effective method to obtain

  5. CT numbers of liver and spleen in normal children

    International Nuclear Information System (INIS)

    Kim, Young Kim

    2002-01-01

    To determine the mean liver CT numbers, and differences between liver and spleen, and liver and back muscle CT numbers in normal children, and to correlate the findings with sex and age. One hundred and five normal children aged 2-14 years underwent pre-contrast CT scanning. Mean CT numbers of the liver, spleen, and back muscles were calculated, as well as the differences in CT numbers between the liver and spleen (liver-spleen CT numbers), and between the liver-back muscle CT numbers were 70.22±6.51 HU, 53.28±3.57 HU, 17.13±6.57 HU, and 11.88±5.94 HU, respectively. Mean liver CT numbers and the difference between liver and back muscle CT numbers were not different by age. By sex, all the CT numbers did not vary according to age. The sex of a subject did not affect the CT number. The children's mean liver CT number was 70.22±6.51 HU and the difference between liver and spleen CT numbers was 17.13±6.57 HU. Younger children had higher liver CT and liver-spleen CT numbers than older children. No CT numbers varied according to sex

  6. Is CT effective in diagnosing the acute appendicitis?: Focus on comparison of unenhanced CT with barium enema

    International Nuclear Information System (INIS)

    Choi, Seong Hee; Hahm, So Hee; Kang Jin Hwa; Moon, Jeong Hwa

    1994-01-01

    To evaluate the role of unenhanced CT in diagnosing the acute appendicitis. We retrospectively analyzed conventional contrast-enhanced abdominal CT scans of 197 normal patients and barium enemas of 26 out of the 197 patients. Additional unenhanced CT scans of right lower abdomen were performed on 30 patients who were suspected of having acute appendicitis; barium enema was performed in 26 patients. In the analysis of the conventional CT scans, we could detect 132 (67%) normal appendices. On barium enema of 26 out of 197 patients, abruptly narrowed appendix was visualized in 5 cases and luminal irregularity in 4 cases but all 26 cases showed normal appendix on CT. In the 30 cases of unenhanced CT, all appendices were visualized. Among 12 cases which were proved as acute appendicitis, barium enema was done in 10 cases; abruptly narrowed appendix was shown in 3 and luminal irregularity in 1. Among 18 cases which were diagnosed as normal appendix, nonvisualization of appendix was in 1 case, abruptly narrowed lumen in 3, and luminal irregularity in 9. Unenhanced CT in the area of the cecum may be an effective and safe diagnostic tool acute appendicitis

  7. Variation in the quality of CT images of the upper abdomen when CT automatic exposure control is employed

    International Nuclear Information System (INIS)

    Aizawa, Isao; Muramatsu, Yoshihisa; Nomura, Keiichi; Shimizu, Fuminori

    2010-01-01

    The aim of this study was to analyze the reason for variation of image quality in the upper abdomen CT with the use of CT-automatic exposure control (AEC). The CT investigated was 3D modulation in the 16 multi detector row CT (MDCT) and lung cancer screening CT (LSCT) phantom was used to simulate the patient. When there was a phase difference, an image noise increase of around 15% at the maximum was accepted. It is concluded that the major reason for variation in image quality is respiratory motion and the importance of respiration control must be recognized. (author)

  8. Multiphase contrast-enhanced CT with highly concentrated contrast agent can be used for PET attenuation correction in integrated PET/CT imaging

    International Nuclear Information System (INIS)

    Aschoff, Philip; Plathow, Christian; Lichy, Matthias P.; Claussen, Claus D.; Pfannenberg, Christina; Beyer, Thomas; Erb, Gunter; Oeksuez, Mehmet Oe.

    2012-01-01

    State-of-the-art positron emission tomography/computed tomography (PET/CT) systems incorporate multislice CT technology, thus facilitating the acquisition of multiphase, contrast-enhanced CT data as part of integrated PET/CT imaging protocols. We assess the influence of a highly concentrated iodinated contrast medium (CM) on quantification and image quality following CT-based attenuation correction (CT-AC) in PET/CT. Twenty-eight patients with suspected malignant liver lesions were enrolled prospectively. PET/CT was performed 60 min after injection of 400 MBq of 18 F-fluorodeoxyglucose (FDG) and following the biphasic administration of an intravenous CM (400 mg iodine/ml, Iomeron 400). PET images were reconstructed with CT-AC using any of four acquired CT image sets: non-enhanced, pre-contrast (n-PET), arterial phase (art-PET), portal venous phase (pv-PET) and late phase (late-PET). Normal tissue activity and liver lesions were assessed visually and quantitatively on each PET/CT image set. Visual assessment of PET following CT-AC revealed no noticeable difference in image appearance or quality when using any of the four CT data sets for CT-AC. A total of 44 PET-positive liver lesions was identified in 21 of 28 patients. There were no false-negative or false-positive lesions on PET. Mean standardized uptake values (SUV) in 36 evaluable lesions were: 5.5 (n-PET), 5.8 (art-PET), 5.8 (pv-PET) and 5.8 (late-PET), with the highest mean increase in mean SUV of 6%. Mean SUV changes in liver background increased by up to 10% from n-PET to pv-PET. Multiphase CT data acquired with the use of highly concentrated CM can be used for qualitative assessment of liver lesions in torso FDG PET/CT. The influence on quantification of FDG uptake is small and negligible for most clinical applications. (orig.)

  9. Predictors of pneumothorax after CT-guided transthoracic needle lung biopsy: the role of quantitative CT.

    Science.gov (United States)

    Chami, H A; Faraj, W; Yehia, Z A; Badour, S A; Sawan, P; Rebeiz, K; Safa, R; Saade, C; Ghandour, B; Shamseddine, A; Mukherji, D; Haydar, A A

    2015-12-01

    To evaluate the association of quantitative computed tomography (CT) measures of emphysema with the occurrence of pneumothorax after CT-guided needle lung biopsy (NLB) accounting for other risk factors. One hundred and sixty-three CT-guided NLBs performed between 2008 and 2013 with available complete chest CT within 30 days were reviewed for the occurrence of post-procedure pneumothorax. Percent emphysema was determined quantitatively as the percentage of lung voxels below -950 HU on chest CT images using automated software. Multivariable regression was used to assess the association of percent emphysema volume with the occurrence of post-procedure pneumothorax. The association of percent emphysema volume with the pneumothorax size and need for chest tube placement after NLB was also explored. Percent emphysema was significantly associated with the incidence of post-NLB pneumothorax (OR=1.10 95% confidence interval: 1.01-1.15; p=0.03) adjusting for lower-lobe lesion location, needle path length, lesion size, number of passes, and pleural needle trajectory angle. Percent emphysema was not associated with the size of the pneumothorax, nor the need for chest tube placement after NLB. Percent emphysema determined quantitatively from chest CT is a significant predictor of post-NLB pneumothorax. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  10. CT of chest trauma

    International Nuclear Information System (INIS)

    Goodman, P.C.

    1986-01-01

    There appears to be a limited role for computed tomography in the evaluation of chest trauma. The literature contains few papers specifically addressing the use of CT in the setting of chest trauma. Another series of articles relates anecdotal experiences in this regard. This paucity of reports attests to the remarkable amount of information present on conventional chest radiographs as well as the lack of clear indications for CT in the setting of chest trauma. In this chapter traumatic lesions of various areas of the thorax are discussed. The conventional radiographic findings are briefly described and the potential or proven application of CT is addressed

  11. CT pelvimetry. La scanopelvimetrie

    Energy Technology Data Exchange (ETDEWEB)

    Vicens, J.L.; Charles, G.; Le Berre, J.; Flageat, J. (Hopital d' Instruction des Armees Begin, 94 - Saint-Mande (FR))

    1989-01-01

    Pelvimetry aims at providing the obstetrician with information on the size and morphology of the female pelvis, thus enabling him to assess the obstetrical prognosis as accurately as possible. Computed tomography (CT) has several advantages, in particular the lower mother and fetus radiation dose. After a brief description of obstetrical anatomy, the usual CT exploration method is presented and its results are considered in terms of measurements, indices and morphological findings. If performed with a very strict exploration procedure, CT pelvimetry is a very reliable, fact and comfortable method of examination. All these advantages, combined with the minimized patient dose, should lead to an increasingly widespread use of this technique.

  12. PET/CT: underlying physics, instrumentation, and advances.

    Science.gov (United States)

    Torres Espallardo, I

    Since it was first introduced, the main goal of PET/CT has been to provide both PET and CT images with high clinical quality and to present them to radiologists and specialists in nuclear medicine as a fused, perfectly aligned image. The use of fused PET and CT images quickly became routine in clinical practice, showing the great potential of these hybrid scanners. Thanks to this success, manufacturers have gone beyond considering CT as a mere attenuation corrector for PET, concentrating instead on design high performance PET and CT scanners with more interesting features. Since the first commercial PET/CT scanner became available in 2001, both the PET component and the CT component have improved immensely. In the case of PET, faster scintillation crystals with high stopping power such as LYSO crystals have enabled more sensitive devices to be built, making it possible to reduce the number of undesired coincidence events and to use time of flight (TOF) techniques. All these advances have improved lesion detection, especially in situations with very noisy backgrounds. Iterative reconstruction methods, together with the corrections carried out during the reconstruction and the use of the point-spread function, have improved image quality. In parallel, CT instrumentation has also improved significantly, and 64- and 128-row detectors have been incorporated into the most modern PET/CT scanners. This makes it possible to obtain high quality diagnostic anatomic images in a few seconds that both enable the correction of PET attenuation and provide information for diagnosis. Furthermore, nowadays nearly all PET/CT scanners have a system that modulates the dose of radiation that the patient is exposed to in the CT study in function of the region scanned. This article reviews the underlying physics of PET and CT imaging separately, describes the changes in the instrumentation and standard protocols in a combined PET/CT system, and finally points out the most important

  13. Usefulness and limit of CT diagnosis on appendicitis

    International Nuclear Information System (INIS)

    Kuchiki, Megumi; Takanashi, Toshiyasu; Yamaguchi, Koichi.

    1997-01-01

    CT was performed in 104 patients with abdominal pain suspected appendicitis. CT showed positive finding (abnormal appendix, appendicolith, pericecal inflammatory change, fluid collection, LN swelling, abscess) and complication of appendicitis clearly. CT diagnosis showed high accuracy than clinical diagnosis. CT proved its usefulness especially only CT imaging showed the correct diagnosis. On the other hand, diverticulitis and terminal ileitis common diagnostic disease of appendicitis showed similar clinical appearance and CT image, caused to be difficult to diagnose correctly. In the cases showing similar image to appendicitis or atypical image, CT also proved its limit of the diagnosis on appendicitis. (author)

  14. Pediatric CT quality management and improvement program

    International Nuclear Information System (INIS)

    Larson, David B.; Chan, Frandics P.; Newman, Beverley; Fleischmann, Dominik; Molvin, Lior Z.; Wang, Jia

    2014-01-01

    Modern CT is a powerful yet increasingly complex technology that continues to rapidly evolve; optimal clinical implementation as well as appropriate quality management and improvement in CT are challenging but attainable. This article outlines the organizational structure on which a CT quality management and improvement program can be built, followed by a discussion of common as well as pediatric-specific challenges. Organizational elements of a CT quality management and improvement program include the formulation of clear objectives; definition of the roles and responsibilities of key personnel; implementation of a technologist training, coaching and feedback program; and use of an efficient and accurate monitoring system. Key personnel and roles include a radiologist as the CT director, a qualified CT medical physicist, as well as technologists with specific responsibilities and adequate time dedicated to operation management, CT protocol management and CT technologist education. Common challenges in managing a clinical CT operation are related to the complexity of newly introduced technology, of training and communication and of performance monitoring. Challenges specific to pediatric patients include the importance of including patient size in protocol and dose considerations, a lower tolerance for error in these patients, and a smaller sample size from which to learn and improve. (orig.)

  15. Pediatric CT quality management and improvement program

    Energy Technology Data Exchange (ETDEWEB)

    Larson, David B.; Chan, Frandics P.; Newman, Beverley; Fleischmann, Dominik [Stanford University School of Medicine, Department of Radiology, Stanford, CA (United States); Molvin, Lior Z. [Stanford Hospital and Clinics, Stanford, CA (United States); Wang, Jia [Stanford University, Environmental Health and Safety, Stanford, CA (United States)

    2014-10-15

    Modern CT is a powerful yet increasingly complex technology that continues to rapidly evolve; optimal clinical implementation as well as appropriate quality management and improvement in CT are challenging but attainable. This article outlines the organizational structure on which a CT quality management and improvement program can be built, followed by a discussion of common as well as pediatric-specific challenges. Organizational elements of a CT quality management and improvement program include the formulation of clear objectives; definition of the roles and responsibilities of key personnel; implementation of a technologist training, coaching and feedback program; and use of an efficient and accurate monitoring system. Key personnel and roles include a radiologist as the CT director, a qualified CT medical physicist, as well as technologists with specific responsibilities and adequate time dedicated to operation management, CT protocol management and CT technologist education. Common challenges in managing a clinical CT operation are related to the complexity of newly introduced technology, of training and communication and of performance monitoring. Challenges specific to pediatric patients include the importance of including patient size in protocol and dose considerations, a lower tolerance for error in these patients, and a smaller sample size from which to learn and improve. (orig.)

  16. Utility of bolus dynamic CT for the detection of hypervascular malignant hepatic tumors. Mainly referring to the comparison with delayed phase contrast-enhanced CT

    International Nuclear Information System (INIS)

    Matsuda, Hiromichi; Abe, Kimihiko; Freeny, P.C.

    1996-01-01

    In order to analyze the usefulness of dynamic contrast-enhanced CT, 84 patients who had hepatocellular carcinoma or suspected hypervascular metastases were studied with conventional incremental dynamic CT (CID-CT) or double helical CT (DH-CT). Delayed phase contrast-enhanced CT studies were consecutively performed in all patients. Thirty-six of 84 patients had malignant hepatic neoplasms; six had hepatocellular carcinoma and 30 had metastatic tumors. At first, the detectability of hepatic lesions was evaluated with bolus dynamic CT and delayed phase CT. Dynamic CT has detected more lesions than delayed CT. Some hepatic lesions described as isodensity were missed on CID-CT. Therefore, delayed phase CT cannot be eliminated when CID-CT is performed. Secondly, hepatic lesion detectability with CID-CT was compared with that of DH-CT. DH-CT did not miss the hepatic lesions picked up by delayed phase CT and was expected to provide excellent detectability of hypervascular hepatic neoplasms. In addition, first helical CT showed most hepatic lesions as areas of obvious hyperdensity, while CID-CT did not show their correct vascularities. So-called hypervascular hepatic tumors, however, were not always hypervascular and were demonstrated as areas of iso-hypodensity even on initial helical scanning. Second helical CT was useful to detect these so-called hypervascular, but actually hypovascular lesions. In conclusion, dynamic CT was helpful in detecting hypervascular hepatic malignant neoplasms, and DH-CT was more accurate than-CID-CT for the detection of hepatic lesions and the evaluation of vascular lesion. (author)

  17. Development of a guideline on reading CT images of malignant pleural mesothelioma and selection of the reference CT films

    International Nuclear Information System (INIS)

    Zhou, Huashi; Tamura, Taro; Kusaka, Yukinori; Suganuma, Narufumi; Subhannachart, Ponglada; Vijitsanguan, Chomphunut; Noisiri, Weeraya; Hering, Kurt G.; Akira, Masanori; Itoh, Harumi

    2012-01-01

    Purpose: International experts developed a guideline on reading CT images of malignant pleural mesothelioma for radiologists and physicians. It is intended that it act as a supplement to the current International Classification of HRCT for Occupational and Environmental Respiratory Diseases. Methods: The research literatures on mesothelioma CT features were systematically reviewed. Ten mesothelioma CT features were adopted into the guideline prepared according to experts’ opinion. The terminology of mesothelioma CT features and mesothelioma probability were agreed by consensus of experts. The CT reference films for each mesothelioma feature were selected based on agreement by experts from 22 definite mesothelioma cases confirmed pathologically and immunohistochemically. To support the validity of the mesothelioma probability, 4 experts’ readings of CT films from 57 cases with or without mesothelioma were analyzed by kappa statistics between the experts; sensitivity and specificity for mesothelioma were also assessed. Results: The mesothelioma CT Guideline was developed, providing the terminology of CT features and the mesothelioma probability, the judgement of severity, the distribution of mesothelioma, and the revised CT reading sheet including mesothelioma items. The CT reference films with ten mesothelioma typical features were selected. The average linearly and quadratically weighted kappa of the agreement on the 4-point scale mesothelioma probability were 0.58 and 0.71, respectively. The average sensitivity and specificity for mesothelioma were 93.2% and 65.6%, respectively. Conclusion: The evidence-based mesothelioma CT Guideline developed may serve as a good educational tool to facilitate physicians in recognising mesothelioma and improve their proficiency in diagnosis of mesothelioma.

  18. Development of a guideline on reading CT images of malignant pleural mesothelioma and selection of the reference CT films

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Huashi, E-mail: zhouhua@u-fukui.ac.jp [Department of Environmental Health, School of Medicine, University of Fukui, 23-3 Shimoaitsuki, Matsuoka, Eihezi-cho, Fukui Prefecture 910-1193 (Japan); Tamura, Taro, E-mail: tarou@u-fukui.ac.jp [Department of Environmental Health, School of Medicine, University of Fukui, 23-3 Shimoaitsuki, Matsuoka, Eihezi-cho, Fukui Prefecture 910-1193 (Japan); Kusaka, Yukinori, E-mail: kusakayk@gmail.com [Department of Environmental Health, School of Medicine, University of Fukui, 23-3 Shimoaitsuki, Matsuoka, Eihezi-cho, Fukui Prefecture 910-1193 (Japan); Suganuma, Narufumi, E-mail: nsuganuma@kochi-u.ac.jp [Department of Environmental Medicine, Kochi University School of Medicine (Japan); Subhannachart, Ponglada, E-mail: pongladas@gmail.com [Central Chest Disease Institute of Thailand, 39 Moo 9, Tiwanon Road, Muang Nonthaburi 11000 (Thailand); Vijitsanguan, Chomphunut, E-mail: Chompoo_vj@yahoo.com [Central Chest Disease Institute of Thailand, 39 Moo 9, Tiwanon Road, Muang Nonthaburi 11000 (Thailand); Noisiri, Weeraya, E-mail: weeraya_tat@yahoo.com [Central Chest Disease Institute of Thailand, 39 Moo 9, Tiwanon Road, Muang Nonthaburi 11000 (Thailand); Hering, Kurt G., E-mail: k.g.hering@t-online.de [Department of Diagnostic Radiology, Radiooncology and Nuclear Medicine, Radiological Clinic, Miner' s Hospital, Radiologische Klinik, Lansppaschaftskranhaus Dortmund, Wieckesweg 27 44309, Dortmund (Germany); Akira, Masanori, E-mail: akira@kch.hosp.go.jp [Department of Radiology, National Hospital Organization Kinki-Chuo Chest Medical Center, 1180 Nagasone-cho, Kita-ku, Sakai, Osaka 591-8555 (Japan); Itoh, Harumi, E-mail: hitoh@fmsrsa.fukui-med.ac.jp [Department of Environmental Health, School of Medicine, University of Fukui, 23-3 Shimoaitsuki, Matsuoka, Eihezi-cho, Fukui Prefecture 910-1193 (Japan); Department of Radiology, School of Medicine, University of Fukui, 23-3 Shimoaitsuki Matsuoka, Eiheizi-cho, Fukui Prefecture 910-1193 (Japan); and others

    2012-12-15

    Purpose: International experts developed a guideline on reading CT images of malignant pleural mesothelioma for radiologists and physicians. It is intended that it act as a supplement to the current International Classification of HRCT for Occupational and Environmental Respiratory Diseases. Methods: The research literatures on mesothelioma CT features were systematically reviewed. Ten mesothelioma CT features were adopted into the guideline prepared according to experts’ opinion. The terminology of mesothelioma CT features and mesothelioma probability were agreed by consensus of experts. The CT reference films for each mesothelioma feature were selected based on agreement by experts from 22 definite mesothelioma cases confirmed pathologically and immunohistochemically. To support the validity of the mesothelioma probability, 4 experts’ readings of CT films from 57 cases with or without mesothelioma were analyzed by kappa statistics between the experts; sensitivity and specificity for mesothelioma were also assessed. Results: The mesothelioma CT Guideline was developed, providing the terminology of CT features and the mesothelioma probability, the judgement of severity, the distribution of mesothelioma, and the revised CT reading sheet including mesothelioma items. The CT reference films with ten mesothelioma typical features were selected. The average linearly and quadratically weighted kappa of the agreement on the 4-point scale mesothelioma probability were 0.58 and 0.71, respectively. The average sensitivity and specificity for mesothelioma were 93.2% and 65.6%, respectively. Conclusion: The evidence-based mesothelioma CT Guideline developed may serve as a good educational tool to facilitate physicians in recognising mesothelioma and improve their proficiency in diagnosis of mesothelioma.

  19. CT of the neonatal head

    International Nuclear Information System (INIS)

    Mohan, S.; Rogan, E.A.; Batty, R.; Raghavan, A.; Whitby, E.H.; Hart, A.R.; Connolly, D.J.A.

    2013-01-01

    Computed tomography (CT) is used less often than other techniques on neonatal units. However, in the acute setting, CT can be invaluable in diagnosing or excluding potentially life-threatening conditions and guiding initial management in neonates. Common indications for scanning include trauma, suspected non-accidental injury, infection, or an acute hypoxic or metabolic event. The aim of this review is to provide an overview of the normal neonatal head at CT and compare this to the common pathological abnormalities. Several key features of each condition will be highlighted. It is important to note that some pathological conditions can have overlapping features at CT and, therefore, the clinical history and additional investigations are also of key importance in determining the diagnosis

  20. Helical CT of ureteral disease

    International Nuclear Information System (INIS)

    Cikman, Pablo; Bengio, Ruben; Bulacio, Javier; Zirulnik, Esteban; Garimaldi, Jorge

    2000-01-01

    Among the new applications of helical CT is the study of the ureteral pathology. The objective of this paper was to evaluate patients with suspected pathology of this organ and the repercussion in the therapeutic plans. We studied 23 patients with a helical CT protocol, without IV contrast injection and performed multiplanar reconstruction (MPR). We called this procedure Pielo CT. Thirteen ureteral stones were detected, 6 calculi, 2 urinary tract tumors, dilatation of the system in a patient with neo-bladder. In 2 patients, in whom ureteral pathology was ruled out, we found other alterations that explained the symptoms, (gallbladder stones, disk protrusion). The Pielo CT let decide a therapeutical approach in 20 or 21 patients with ureteral pathology. (author)