WorldWideScience

Sample records for gamma spectrometer module

  1. Multichannel CdZnTe Gamma Ray Spectrometer

    International Nuclear Information System (INIS)

    Doty, F.P.; Lingren, C. L.; Apotovsky, B. A.; Brunsch, J.; Butler, J. F.; Collins, T.; Conwell, R.L.; Friesenhahn, S.; Gormley, J.; Pi, B.; Zhao, S.; Augustine, F.L.; Bennet, B. A.; Cross, E.; James, R. B.

    1998-01-01

    A 3 cm 3 multichannel gamma spectrometer for DOE applications is under development by Digirad Corporation. The device is based on a position sensitive detector packaged in a compact multi-chip module (MCM) with integrated readout circuitry. The modular, multichannel design will enable identification and quantitative analysis of radionuclides in extended sources, or sources containing low levels of activity. The MCM approach has the advantages that the modules are designed for imaging applications, and the sensitivity can be arbitrarily increased by increasing the number of pixels, i.e. adding modules to the instrument. For a high sensitivity probe, the outputs for each pixel can be corrected for gain and offset variations, and summed digitally. Single pixel results obtained with discrete low noise readout indicate energy resolution of 3 keV can be approached with currently available CdZnTe. The energy resolution demonstrated to date with MCMs for 511 keV gamma rays is 10 keV

  2. Using the computer simulation methods for the PHOS gamma spectrometer in the ALICE design. Pt. 1. Simulation of the base module response on a high-energy gamma quantum

    International Nuclear Information System (INIS)

    Antonenko, V.G.; Blau, D.S.

    2006-01-01

    After all lead tungstate crystals have been fabricated and transferred for assembling of the gamma-spectrometer PHOS in frame of ALICE experiment on the Large Hadron Collider a simulation was performed of the light collection in single scintillation module taking into account realistic properties of entire crystal party [ru

  3. A gamma scintillation spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Symbalisty, S

    1952-07-01

    A scintillation type gamma ray spectrometer employing coincidence counting, designed and built at the Physics Department of the University of Western Ontario is described. The spectrometer is composed of two anthracene and photomultiplier radiation detectors, two pulse analyzing channels, a coincidence stage, three scalers and a high voltage stabilized supply. A preliminary experiment to test the operation of the spectrometer was performed and the results of this test are presented. (author)

  4. Development of a cosmic veto gamma-spectrometer

    International Nuclear Information System (INIS)

    Burnett, J.L.; Davies, A.V.

    2012-01-01

    Cosmic radiation contributes significantly towards the background radiation measured by a gamma-spectrometer. A novel cosmic veto gamma-spectrometer has been developed that provides a mean background reduction of 54.5%. The system consists of plastic scintillation plates operated in time-stamp mode to detect coincident muon interactions within an HPGe gamma-spectrometer. The instrument is easily configurable and provides improved sensitivity for radionuclides indicative of nuclear weapons tests and reactor incidents, including 140 Ba, 95 Zr, 99 Mo, 141 Ce, 147 Nd, 131 I, 134 Cs and 137 Cs. This has been demonstrated for Comprehensive Nuclear-Test-Ban Treaty applications to obtain the required 140 Ba MDA of 24 mBq within 2 days counting. Analysis of an air filter sample collected during the Fukushima incident indicates improved sensitivity compared to conventional gamma-spectrometers. (author)

  5. Gamma-ray spectrometer utilizing xenon at high pressure

    International Nuclear Information System (INIS)

    Smith, G.C.; Mahler, G.J.; Yu, B.; Kane, W.R.; Markey, J.K.

    1994-01-01

    A prototype gamma-ray spectrometer utilizing xenon gas near the critical point (166 degrees C, 58 atm) is under development. The spectrometer will function as a room-temperature ionization chamber detecting gamma rays in the energy range 100 keV2 MeV, with an energy resolution intermediate between semiconductor (Ge) and scintillation (NaI) spectrometers. The energy resolution is superior to that of a NaI scintillation spectrometer by a substantial margin (approximately a factor 5), and accordingly, much more information can be extracted from a given gamma-ray spectrum. Unlike germanium detectors, the spectrometer possesses the capability for sustained operation under ambient temperature conditions without a requirement for liquid nitrogen

  6. Development of gamma spectrometer using silicon photomultiplier (SiPM)

    International Nuclear Information System (INIS)

    Kim, Chan Kyu

    2011-02-01

    Gamma spectroscopy is used to determine the identity and quantity of gamma-emitters in nuclear physics, geochemistry and astrophysics. The scintillation detectors are being used as a gamma spectrometer generally, because of their higher gamma-ray detection efficiency and cheaper price than germanium semi-conductor detectors. A typical scintillation detector is composed of a scintillator, a window, and a photodetector. The photomultiplier (PM) tube has been the most widely used as a photodetector because of its advantages like high sensitivity, high signal-to-noise ratio, and wide dynamic range. Recently, the Silicon Photomultiplier (SiPM) is being studied as a substitute of PM tube. The SiPM has almost same performance compared to PM tube but it has additional advantages; low operating voltage, small volume, and cheap production cost. In this research, the gamma spectrometer using SiPM instead of PM tube is developed. The use of SiPM as a photodetector makes the gamma spectrometer smaller, cheaper, easier to use. For photon transport and collection from the large area scintillator to the small area SiPM, a light guide is applied in this gamma spectrometer system. Before fabrication of light guide, DETECT simulation is performed to study and prospect characteristics of light guide structure. And actual light guides are fabricated on the basis of this simulation result. Poly(methyl methacrylate) (PMMA) is chosen as material of light guide, 5 sample light guides are fabricated in different lengths and coatings. As a scintillator crystal, same NaI(Tl) crystal is chosen. For measurement and analysis of gamma spectrometer system, 3 gamma spectrometer systems are composed: PM tube-based system, PM tube-based system with the light guide, SiPM-based system with the light guide. Through comparison between the results of each gamma spectrometer, the performances of gamma spectrometer system are analyzed by each component. Measurement results of the second system is well

  7. Portable scintillation gamma-spectrometer for field measurement of radioactivity in extensive objects

    International Nuclear Information System (INIS)

    Besshejko, O.A.; Vishnevskij, I.N.; Denisenko, R.V.; Malyuk, I.A.; Petrosyan, Eh.E.; Karpenko, S.A.; Prijmak, V.N.

    2011-01-01

    The portable scintillated gamma-spectrometer for field measurement of radioactivity in the volume objects was designed. The crystal CdWO 4 that has weak dependence of light yield from temperature in combination with PMT was applied as the gamma-rays detector. The design of the device provides the possibility for measuring radioactivity of the extensive objects in 4π-geometry without background measurements. In this case the value of the efficiency needed for specific activity calculation in close approximation depends only from crystal geometry and density of measuring object and may be set as the device parameter without efficiency calibration procedure during the operation. The spectrometer does not have an auxiliary radio-active source and connecting cables in the composition. The smartphone operated under Windows Mobile is used as the control module. Bluetooth connection provides data exchange between smartphone and measurement head.

  8. Imaging of gamma rays with the WINKLER high-resolution germanium spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Fisher, T.R.; Hamilton, T.W.; Hawley, J.D.; Kilner, J.R.; Murphy, M.J.; Nakano, G.H. (Luckheed Palo Alto Research Lab., Palo Alto, CA (US))

    1990-06-01

    The WINKLER spectrometer is a matrix of nine high-purity {ital n}-type germanium detectors developed for astrophysical observations and terrestrial radiation monitoring. The spectrometer has been fitted with a set of modulation collimator grids designed for imaging hard x-ray and gamma-ray sources by the Mertz, Nakano, and Kilner method. This technique employs a pair of gridded collimators in front of each detector with the number of grid bars varying from one to {ital N}, where {ital N} is the number of detectors. When the collimator pairs are rotated through a full 360-degree angular range, the detector signals provide the information for a two-dimensional band-limited Fourier reconstruction of order {ital N}. Tests of the spectrometer with single and multiple point sources as well as continuous source distributions are reported.

  9. Portable scintillation gamma-spectrometer for field measurement of radioactivity in extensive objects

    Directory of Open Access Journals (Sweden)

    O. A. Bezshyyko

    2011-12-01

    Full Text Available The portable scintillated gamma-spectrometer for field measurement of radioactivity in the volume objects was designed. The crystal CdWO4 that has weak dependence of light yield from temperature in combination with PMT was applied as the gamma-rays detector. The design of the device provides the possibility for measuring radioactivity of the extensive objects in 4-geometry without background measurements. In this case the value of the efficiency needed for specific activity calculation in close approximation depends only from crystal geometry and density of measuring object and may be set as the device parameter without efficiency calibration procedure during the operation. The spectrometer does not have an auxiliary radio-active source and connecting cables in the composition. The smartphone operated under Windows Mobile is used as the control module. Bluetooth connection provides data exchange between smartphone and measurement head.

  10. Deadtime measurement for the new gamma spectrometer system

    International Nuclear Information System (INIS)

    Chen Fangqiang; Ge Liangquan; Luo Yaoyao; Ni Weichong; Zeng Guoqiang; An Zhengwei; Mi Yaohui

    2010-01-01

    It introduces the reasons,the representation,the related theory and the measuring steps of the traditional dual-source method. And we also introduce a new kind of airborne Gamma-Ray spectrometer. In single connection circumstances, we confirmed the validity of the dual-source net counts method by comparing the results of four modes. The deadtime of the new kind of airborne Gamma-Ray spectrometer is measured, and the conclusion and some advice are given. (authors)

  11. Airborne gamma ray spectrometer surveying

    International Nuclear Information System (INIS)

    1991-01-01

    The International Atomic Energy Agency (IAEA) in its role as collector and disseminator of information on nuclear techniques has long had an interest in gamma ray spectrometer methods and has published a number of Technical Reports on various aspects of the subject. At an Advisory Group Meeting held in Vienna in November 1986 to review appropriate activities the IAEA could take following the Chernobyl accident, it was recommended that preparation begin on a new Technical Report on airborne gamma ray spectrometer surveying, taking into account the use of the technique for environmental monitoring as well as for nuclear emergency response requirements. Shortly thereafter the IAEA became the lead organization in the Radioelement Geochemical Mapping section of the International Geological Correlation Programme/United Nations Educational, Scientific and Cultural Organization (UNESCO) Project on International Geochemical Mapping. These two factors led to the preparation of the present Technical Report. 18 figs, 4 tabs

  12. Development of a Gamma Spectrometer using a Large NaI Scintillator and SiPMs

    International Nuclear Information System (INIS)

    Kim, Chankyu; Yoo, Hyunjun; Kim, Yewon and others

    2014-01-01

    A typical scintillation gamma spectrometer is composed of a NaI(Tl) scintillation crystal and a PM tube. From last years, a Silicon Photomultiplier (SiPM) is being developed and expanding its application area as a substitute of PM tube due to its advantages like low operating voltage, small volume, and cheap production cost, MR compatibility. This approach could make gamma spectrometer smaller, cheaper, easier to use, and these advantage are quite suitable to original purpose of scintillation gamma spectrometer. Gamma spectrometry and gamma spectrometer is used to analyze gamma source in nuclear science, geochemistry, and astrophysics. In this research, gamma spectrometer which uses SiPMs instead of PM tube is proposed. The proposed gamma spectrometer has advantages of low cost, small volume, low operation voltage; but it has disadvantages of performances. To reduce this loss in performances, a light guide of effective structure is required. (Material, reflection type, tapering angle) For design of the light guide, DETECT simulation was performed. And through DETECT simulation, the characteristics of light guide could be prospected. Actual light guide was manufactured on the basis of this simulation result. Using the light guide, gamma spectrometer system was composed and tested. In the test result, gamma spectrometer using SiPM shows degraded energy resolution. The reason of this degradation is being analyzed and the test system is under modification

  13. Characterization of a new modular decay total absorption gamma-ray spectrometer (DTAS) for FAIR

    International Nuclear Information System (INIS)

    Montaner Pizá, A.; Taín, J. L.; Agramunt, J.; Algora, A.; Guadilla, V.; Marín, E.; Rice, S.; Rubio, B.

    2013-01-01

    Beta-decay studies are one of the main goals of the DEcay SPECtroscopy experiment (DESPEC) to be installed at the future Facility for Antiproton and Ion Research (FAIR). DESPEC aims at the study of nuclear structure of exotic nuclei. A new modular Decay Total Absorption gamma-ray Spectrometer (DTAS) is being built at IFIC and is specially adapted to studies at fragmentation facilities such as the Super Fragment Separator (Super-FRS) at FAIR. The designed spectrometer is composed of 16 identical NaI(Tl) scintillation crystals. This work focuses on the characterization of these independent modules, as an initial step for the characterization of the full spectrometer. Monte Carlo simulations have been performed in order to understand the detector response.

  14. A gamma-gamma coincidence/anticoincidence spectrometer for low-level cosmogenic (22)Na/(7)Be activity ratio measurement.

    Science.gov (United States)

    Zhang, Weihua; Ungar, Kurt; Stukel, Matthew; Mekarski, Pawel

    2014-04-01

    In this study, a digital gamma-gamma coincidence/anticoincidence spectrometer was developed and examined for low-level cosmogenic (22)Na and (7)Be in air-filter sample monitoring. The spectrometer consists of two bismuth germanate scintillators (BGO) and an XIA LLC Digital Gamma Finder (DGF)/Pixie-4 software and card package. The spectrometer design allows a more selective measurement of (22)Na with a significant background reduction by gamma-gamma coincidence events processing. Hence, the system provides a more sensitive way to quantify trace amounts of (22)Na than normal high resolution gamma spectrometry providing a critical limit of 3 mBq within a 20 h count. The use of a list-mode data acquisition technique enabled simultaneous determination of (22)Na and (7)Be activity concentrations using a single measurement by coincidence and anticoincidence mode respectively. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Study and development of a spectrometer with Compton suppression and gamma coincidence counting

    International Nuclear Information System (INIS)

    Masse, D.

    1990-10-01

    This paper presents the characteristics of a spectrometer consisting of a Ge detector surrounded by a NaI(T1) detector that can operate in Compton-suppression and gamma-gamma coincidence modes. The criteria that led to this measurement configuration are discussed and the spectrometer performances are shown for 60 Co and 137 Cs gamma-ray sources. The results for the measurement of 189 Ir (Compton suppression) and for the measurement of 101 Rh (gamma-gamma coincidence) in the presence of other radioisotopes are given. 83 Rb and 105 Ag isotopes are also measured with this spectrometer [fr

  16. Borehole instrument for scintillation gamma spectrometer

    International Nuclear Information System (INIS)

    Sinitsyn, A.Ya.; Gabitov, R.M.

    1979-01-01

    Described are a schematic diagram and main specifications of a borehole instrument with autostabilization of energy scale measure by gamma bench-mark of 137 Cs, intended for the application in a logging gamma spectrometer to determine separately the concentrations of nature radioactive elements. The instrument may be connected to the KOBDFM-2 cable of 600 m length. It contains a scintillation counter for gamma quanta consisting of 30x70 mm NaI(Tl) crystal and a FEU-85 photoamplifier, an input conforming stage, a diagram of threshold pulse formation and regulating high-voltage generator. The borehole instrument has been proved under laboratory and field conditions at 10-40 deg C

  17. Gamma-Ray Imaging Spectrometer (GRIS): a new balloon-borne experiment for gamma-ray line astronomy

    International Nuclear Information System (INIS)

    Teegarden, B.J.; Cline, T.L.; Gehrels, N.; Porreca, G.; Tueller, J.; Leventhal, M.; Huters, A.F.; Maccallum, C.J.; Stang, P.D.; Sandia Labs., Albuquerque, NM)

    1985-01-01

    High resolution gamma-ray spectroscopy is a relatively new field that holds great promise for further understanding of high energy astrophysical processes. When the high resolution gamma-ray spectrometer (GRSE) was removed from the GRO payload, a balloon program was initiated to permit continued development and improvement of instrumentation in this field, as well as continued scientific observations. The Gamma-Ray Imaging Spectrometer (GRIS) is one of the experiments selected as part of this program. The instrument contains a number of new and innovative features that are expected to produce a significant improvement in source location accuracy and sensitivity over previous balloon and satellite experiments

  18. Frequency-Modulation Correlation Spectrometer

    Science.gov (United States)

    Margolis, J. S.; Martonchik, J. V.

    1985-01-01

    New type of correlation spectrometer eliminates need to shift between two cells, one empty and one containing reference gas. Electrooptical phase modulator sinusoidally shift frequencies of sample transmission spectrum.

  19. High-sensitivity multidimensional gamma-ray spectrometer, PRIPYAT` for low-level measurements

    Energy Technology Data Exchange (ETDEWEB)

    Andrukhovich, S K [and others

    1996-12-31

    The design of the gamma spectrometer PRIPYAT` intended for gamma spectra measurement in the energy range 0.2-3 MeV is discussed. The spectrometer may be used for the food and water control as well as for massive control of environmental contamination. Its background at Cs{sup 134} + Cs{sup 137} measurement regime is less then 9 c/s. 1 fig.

  20. Improved yield of high resolution mercuric iodide gamma-ray spectrometers

    International Nuclear Information System (INIS)

    Gerrish, V.; van den Berg, L.

    1990-01-01

    Mercuric iodide (HgI 2 ) exhibits properties which make it attractive for use as a solid state nuclear radiation detector. The wide bandgap (E g = 2.1 eV) and low dark current allow room temperature operation, while the high atomic number provides a large gamma-ray cross section. However, poor hole transport has been a major limitation in the routine fabrication of high-resolution spectrometers using this material. This paper presents the results of gamma-ray response and charge transport parameter measurements conducted during the past year at EG ampersand G/EM on 96 HgI 2 spectrometers. The gamma-ray response measurements reveal that detector quality is correlated with the starting material used in the crystal growth. In particular, an increased yield of high-resolution spectrometers was obtained from HgI 2 which was synthesized by precipitation from an aqueous solution, as opposed to using material from commercial vendors. Data are also presented which suggest that better spectrometer performance is tied to improved hole transport. Finally, some initial results on a study of detector uniformity reveal spatial variations which may explain why the correlation between hole transport parameters and spectrometer performance is sometimes violated. 6 refs., 3 figs

  1. Calibration and control modules for gamma-ray borehole loggers

    International Nuclear Information System (INIS)

    1983-01-01

    A calibration pad for quantitative evaluation of gamma-ray logs, developed and constructed by CNEA is described. The facility is composed of a set of mineralized modules with which it is intended to reproduce the natural variable conditions found in boreholes drilled for uranium mineral exploration, such as the ore concentration, rock's density and porosity, water content, etc. The facility is able to operate under different radiometric models, as follow: 1) gross-count gamma-ray models; 2) gamma-spectrometer models; 3) neutronic-fission models, and 4) models for determination of magnetic susceptibility, density, neutron-neutron, etc. The gathered information allows the adequate quantitative radiometric evaluation of the ore bodies crossed by exploration holes, and also allows the correlation of gamma-ray logs obtained by different logger-equipments. The paper includes the description of the project development and the standards established for the facility's operation. (M.E.L.) [es

  2. Portable gamma-ray spectrometers and spectrometry systems

    International Nuclear Information System (INIS)

    Shebell, P.

    1999-01-01

    The current state-of-the-art in portable gamma-ray spectrometers and portable spectrometry systems is discussed. A comparison of detector performance and features of commercially available systems are summarised. Finally, several applications of portable systems are described. (author)

  3. Particle transport simulation for spaceborne, NaI gamma-ray spectrometers

    International Nuclear Information System (INIS)

    Dyer, C.S.; Truscott, P.R.; Sims, A.J.; Comber, C.; Hammond, N.D.A.

    1988-11-01

    Radioactivity induced in detectors by protons and secondary neutrons limits the sensitivity of spaceborne gamma-ray spectrometers. Three dimensional Monte Carlo transport codes have been employed to simulate particle transport of cosmic rays and inner-belt protons in various representations of the Gamma Ray Observatory Spacecraft and the Oriented Scintillation Spectrometer Experiment. Results are used to accurately quantify the contributions to the radioactive background, assess shielding options and examine the effect of detector and space-craft orientation in anisotropic trapped proton fluxes. (author)

  4. A gamma-ray spectrometer system for fusion applications

    CERN Document Server

    Esposito, B; Kaschuck, Y A; Martin-Solis, J R; Portnov, D V

    2002-01-01

    A NaI scintillator spectrometer system for the measurement of gamma-ray spectra in tokamak discharges has been developed and installed on the Frascati Tokamak Upgrade. Two NaI scintillators are viewing the plasma at two different angles with respect to the equatorial plane. The main features of the spectrometer system (energy range: 0.3-23 MeV) and of the unfolding technique used to restore physical spectra from the pulse-height distributions are described: a method of solution with regularisation for matrix equations of large size, allowing to process count distributions with significant statistical noise, has been developed. A dedicated software, portable to any platform, has been written both for the acquisition and the analysis of the spectra. The typical gamma-ray spectra recorded in hydrogen and deuterium discharges, also with additional heating, are presented and discussed; two components have been observed: (a) thick-target Bremsstrahlung gamma-rays produced by runaway electrons hitting the Inconel po...

  5. Control system and automation of the spectrum acquisition for a perturbed gamma-gamma angular correlation spectrometer

    International Nuclear Information System (INIS)

    Stachowski, Ademir F.A.; Lapolli, André L.; Carbonari, Artur W.; Saxena, Rajendra N.

    2017-01-01

    This work reports results from the automation of data acquisition for a gamma-gamma perturbed angular correlation (PAC) spectrometer located in the hyperfine interactions laboratory (LIH) of IPEN. A PAC spectrometer comprises usually four scintillation detectors (BaF_3 for example) and carries out time measurements from gamma rays of any two combinations of detectors in coincidence. Gamma rays come from the decay of probe nuclei embedded into the material to be studied. Measurements are generally performed as a function of temperature. The fourth-detectors PAC spectrometer was automated in Java language because it is a multi platform and object oriented programming language, having, therefore, portability and longer lifetime due to the ease of implementation of peripherals. Finally, the software has a friendly and intuitive interface with the user being able to operate the hardware manually or automatically with time acquisitions up to 100 consecutive hours. Before each acquisition, the software sets the temperature, waits for temperature stability and records data in different files. Moreover, the software also saves in a file all information of relevant parameters during acquisition. (author)

  6. Control system and automation of the spectrum acquisition for a perturbed gamma-gamma angular correlation spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Stachowski, Ademir F.A.; Lapolli, André L.; Carbonari, Artur W.; Saxena, Rajendra N., E-mail: alapolli@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-11-01

    This work reports results from the automation of data acquisition for a gamma-gamma perturbed angular correlation (PAC) spectrometer located in the hyperfine interactions laboratory (LIH) of IPEN. A PAC spectrometer comprises usually four scintillation detectors (BaF{sub 3} for example) and carries out time measurements from gamma rays of any two combinations of detectors in coincidence. Gamma rays come from the decay of probe nuclei embedded into the material to be studied. Measurements are generally performed as a function of temperature. The fourth-detectors PAC spectrometer was automated in Java language because it is a multi platform and object oriented programming language, having, therefore, portability and longer lifetime due to the ease of implementation of peripherals. Finally, the software has a friendly and intuitive interface with the user being able to operate the hardware manually or automatically with time acquisitions up to 100 consecutive hours. Before each acquisition, the software sets the temperature, waits for temperature stability and records data in different files. Moreover, the software also saves in a file all information of relevant parameters during acquisition. (author)

  7. Portable scintillation gamma-spectrometer for field measurement of radioactivity in extensive objects; Portativnyj stsintillyatsionnyj gamma-spektrometr dlya izmereniya radioaktivnosti ob''emnykh sred v polevykh usloviyakh

    Energy Technology Data Exchange (ETDEWEB)

    Besshejko, O. A. [Taras Shevchenko National University of Kyiv, Kyiv (Ukraine); Vishnevskij, I. N.; Denisenko, R. V.; Malyuk, I. A.; Petrosyan, Eh. E. [Institute for Nuclear Research, Kyiv (Ukraine); Karpenko, S. A.; Prijmak, V. N. [Ukrainian Association for Valves Industry, Dnepropetrovsk (Ukraine)

    2011-07-01

    The portable scintillated gamma-spectrometer for field measurement of radioactivity in the volume objects was designed. The crystal CdWO{sub 4} that has weak dependence of light yield from temperature in combination with PMT was applied as the gamma-rays detector. The design of the device provides the possibility for measuring radioactivity of the extensive objects in 4{pi}-geometry without background measurements. In this case the value of the efficiency needed for specific activity calculation in close approximation depends only from crystal geometry and density of measuring object and may be set as the device parameter without efficiency calibration procedure during the operation. The spectrometer does not have an auxiliary radio-active source and connecting cables in the composition. The smartphone operated under Windows Mobile is used as the control module. Bluetooth connection provides data exchange between smartphone and measurement head.

  8. Measurement of the radiative decay width {gamma}[{lambda}(1520)->{lambda}{gamma}] with the SPHINX spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Antipov, Yu.M. [Institute for High Energy Physics, Protvino (Russian Federation); Artamonov, A.V. [Institute for High Energy Physics, Protvino (Russian Federation); Batarin, V.A. [Institute for High Energy Physics, Protvino (Russian Federation); Vavilov, D.V. [Institute for High Energy Physics, Protvino (Russian Federation); Victorov, V.A. [Institute for High Energy Physics, Protvino (Russian Federation); Eroshin, O.V. [Institute for High Energy Physics, Protvino (Russian Federation); Golovkin, S.V. [Institute for High Energy Physics, Protvino (Russian Federation); Gorin, Yu.P. [Institute for High Energy Physics, Protvino (Russian Federation); Kolganov, V.Z. [Institute of Theoretical and Experimental Physics, Moscow (Russian Federation); Kozhevnikov, A.P. [Institute for High Energy Physics, Protvino (Russian Federation); Konstantinov, A.S. [Institute for High Energy Physics, Protvino (Russian Federation); Kubarovsky, V.P. [Institute for High Energy Physics, Protvino (Russian Federation); Kurshetsov, V.F. [Institute for High Energy Physics, Protvino (Russian Federation); Landsberg, L.G. [Institute for High Energy Physics, Protvino (Russian Federation)]. E-mail: lgl@mx.ihep.su; Leontiev, V.M. [Institute for High Energy Physics, Protvino (Russian Federation); Lomkatsi, G.S. [Institute of Theoretical and Experimental Physics, Moscow (Russian Federation); Molchanov, V.V. [Institute for High Energy Physics, Protvino (Russian Federation)]. E-mail: molchanov@mx.ihep.su; Mukhin, V.A. [Institute for High Energy Physics, Protvino (Russian Federation); Nilov, A.F. [Institute of Theoretical and Experimental Physics, Moscow (Russian Federation); Patalakha, D.I. [Institute for High Energy Physics, Protvino (Russian Federation); Petrenko, S.V. [Institute for High Energy Physics, Protvino (Russian Federation); Smolyankin, V.T. [Institute of Theoretical and Experimental Physics, Moscow (Russian Federation)

    2004-12-16

    The radiative decay {lambda}(1520)->{lambda}{gamma} was measured directly in the study of the exclusive diffractive-like reaction p+N->{lambda}(1520)K{sup +}+N, {lambda}(1520)->{lambda}{gamma} with the SPHINX spectrometer. The values of the branching and partial width of this radiative decay were obtained: BR[{lambda}(1520)->{lambda}{gamma}]=(1.02+/-0.21(stat)+/-0.15(syst))x10{sup -2} and {gamma}[{lambda}(1520)->{lambda}{gamma}]=159+/-33(stat)+/-26(syst)-bar keV.

  9. A field-deployable gamma-ray spectrometer utilizing xenon at high pressure

    International Nuclear Information System (INIS)

    Smith, G.C.; Mahler, G.J.; Yu, B.; Salwen, C.; Kane, W.R.; Lemley, J.R.

    1996-01-01

    Prototype gamma-ray spectrometers utilizing xenon gas at high pressure, suitable for applications in the nuclear safeguards, arms control, and nonproliferation communities, have been developed at Brookhaven National Laboratory (BNL). These spectrometers function as ambient-temperature ionization chambers detecting gamma rays with good efficiency in the energy range 50 keV - 2 MeV, with an energy resolution intermediate between semiconductor (Ge) and scintillation (NaI) spectrometers. They are capable of prolonged, low-power operation without a requirement for cryogenic fluids or other cooling mechanisms, and with the addition of small quantities of 3 He gas, can function simultaneously as efficient thermal neutron detectors

  10. Further development of a cosmic veto gamma-spectrometer

    International Nuclear Information System (INIS)

    Burnett, J.L.; Davies, A.V.; McLarty, J.L.

    2013-01-01

    The Comprehensive Nuclear-Test-Ban Treaty (CTBT) is supported by a network of certified laboratories that perform high-resolution gamma-spectrometry on global air filter samples for the identification of 85 radionuclides. At the UK CTBT Radionuclide Laboratory (GBL15), a novel cosmic veto gamma-spectrometer has been developed to improve the sensitivity of measurements for treaty compliance. The system consists of plastic scintillation plates operated in time-stamp mode to detect coincident cosmic-ray interactions within an HPGe gamma-spectrometer. This provides a mean background reduction of 75.2 % with MDA improvements of 45.6 %. The CTBT requirement for a 140 Ba MDA is achievable after 1.5 days counting compared to 5-7 days using conventional systems. The system does not require dedicated coincidence electronics, and remains easily configurable with dual acquisition of unsuppressed and suppressed spectra. Performance has been significantly improved by complete processing of the cosmic-ray spectrum (0-25 MeV) combined with the Canberra Lynx TM multi-channel analyser. The improved sensitivity has been demonstrated for a CTBT air filter sample collected after the Fukushima incident. (author)

  11. Monitoring of Natural Soil Radioactivity with Portable Gamma-Ray Spectrometers

    DEFF Research Database (Denmark)

    Bøtter-Jensen, Lars; Løvborg, Leif; Kirkegaard, Peter

    1979-01-01

    Two portable NaI(Tl) spectrometers with four energy windows were used for the recording of gamma-ray counts over soil and rock of differing natural radioactivity. The exposure rates at the field sites were simultaneously measured with a high-pressure argon ionization chamber. Background measureme......Two portable NaI(Tl) spectrometers with four energy windows were used for the recording of gamma-ray counts over soil and rock of differing natural radioactivity. The exposure rates at the field sites were simultaneously measured with a high-pressure argon ionization chamber. Background...... measurements at sea were carried out in order to estimate the non-terrestrial contributions to the instrument readings. Counts recorded in the three high-energy windows of the spectrometers were converted into radiometrically equivalent concentrations of thorium, uranium, and potassium in the ground. Large....... The theoretical exposure rates deducible from the experimental radioelement concentrations at the field sites were in good agreement both with the ionization-chamber readings (corrected for cosmic-ray background) and with the exposure rates measured by total gamma-ray counting. From this and other results...

  12. Remote planetary geochemical exploration with the NEAR X-ray/gamma-ray spectrometer

    International Nuclear Information System (INIS)

    Trombka, J.I.; Boynton, W.V.; Brueckner, J.; Squyres, S.; Clark, P.E.; Starr, R.; Evans, L.G.; Floyd, S.R.; McClanahan, T.P.; Goldsten, J.; Mcnutt, R.; Schweitzer, J.S.

    1999-01-01

    The X-ray/gamma-ray spectrometer (XGRS) instrument onboard the Near Earth Asteroid Rendezvous (NEAR) spacecraft will map asteroid 433 Eros in the 0.2 keV to 10 MeV energy region. Measurements of the discrete line X-ray and gamma-ray emissions in this energy domain can be used to obtain both qualitative and quantitative elemental composition maps of the asteroid surface. The NEAR X-ray/gamma-ray spectrometer (XGRS) was turned on for the first time during the week of 7 April 1996. Rendezvous with Eros 433 is expected during December 1998. Observations of solar X-ray spectra during both quiescent and active periods have been made. A gamma-ray transient detection system has been implemented and about three gamma-ray transient events a week have been observed which are associated with either gamma-ray bursts or solar flares

  13. Time-of-flight spectrometer for the measurement of gamma correlated neutron spectra

    International Nuclear Information System (INIS)

    Andriashin, A.V.; Devkin, B.V.; Lychagin, A.A.; Minko, J.V.; Mironov, A.N.; Nesterenko, V.S.; Sztaricskai, T.; Petoe, G.; Vasvary, L.

    1986-01-01

    A time-of-flight spectrometer for the measurement of gamma correlated neutron spectra from (n,xnγ) reactions is described. The operation and the main parameters are discussed. The resolution in the neutron channel is 2.2 ns/m at the 150 keV neutron energy threshold. A simultaneous measurement of the time-of-flight and amplitude distributions makes it possible to study gamma correlated neutron spectra as well as the prompt gamma spectra in coincidence with selected energy neutrons. In order to test the spectrometer, measurements of the neutron spectrum in coincidence with the 846 keV gamma line of 56 Fe were carried out at an incident neutron energy of 14.1 MeV. (Auth.)

  14. Deep-water gamma-spectrometer based on HP(Ge) detector

    International Nuclear Information System (INIS)

    Sokolov, A.; Danengirsh, S.; Popov, S.; Pchelincev, A; Gostilo, V.; Kravchenko, S.; Shapovalov, V.; Druzhinin, A.

    1995-01-01

    Full text: For radionuclide monitoring of the sea bottom near underwater storage of high active waste of nuclear industries and near places of accidents with nuclear submarines the spectrometers of gamma-radiation, which allow to carry out the measurements on the great depth, are needed. Usually, these problems are solved with devices, which are cast down into the water, using the rope, and transmit the signals on the surface by the cable. However, the depth of immersion is limited by this construction and often the conditions of measurement are complicated. The deep water gamma-spectrometer based on HP(Ge) detector for the measurement on the depth up to 3000 m is developed. The spectrometer is completely autonomic and is put up in the selected place, using the manipulator of a deep-water apparatus. The spectrometer is created in two cylindrical cases with 170 mm diameter and 1100 mm length, bearing the high hydrostatic pressure. The part of the case around the detector is created from titanium and has especial construction with a thin wall for increasing the efficiency of registration in the region of low-energy gamma-radiation. The cooling of the semiconductor detector is provided by a coolant which supports the working temperature of the detector during more than 24 hours. The electronic system of the spectrometer includes high voltage supply f or the detector, preamplifier, analog processor, analog-digital converter and a device for collecting and storing information in flash memory. The power supply of the spectrometer is provided by a battery of accumulators, which can be recharged on the surface. The programming of the processor is carried out before immersion by connecting the spectrometer to personal computer using standard interface RS-232. During 24 hours the spectrometer provides registration of 16 spectrums each in 4096 channels. The reading of the information by the computer is carried out after lifting up the spectrometer on the surface in the same

  15. Time-of-flight spectrometer for the measurement of gamma correlated neutron spectra

    International Nuclear Information System (INIS)

    Andryashin, A.V.; Devlein, B.V.; Lychagin, A.A.; Minko, Y.V.; Mironov, A.N.; Nesterenko, V.S.

    1986-01-01

    A time-of-flight spectrometer for the measurement of gamma correlated neutron spectra form (n,xnγ) reactions is described. The operation and the main parameters are discussed. The resolution in the neutron channel is 2.2 ns/m at the 150 keV neutron energy threshold. A simultaneous measurement of the time-of-flight and amplitude distributions makes it possible to study gamma correlated neutron spectra as well as the prompt gamma spectra in coincidence with selected energy neutrons. In order to test the spectrometer, measurements of the neutron spectrum in coincidence with the 846 keV gamma line of 56 Fe were carried out at an incident neutron energy of 14.1 MeV. (author). 3 figs., 6 refs

  16. Gamma-ray imaging spectrometer (GRIS): a new balloon-borne experiment for gamma-ray line astronomy

    International Nuclear Information System (INIS)

    Teegarden, B.J.; Cline, T.L.; Gehrels, N.; Porreca, G.; Tueller, J.; Leventhal, M.; Huters, A.F.; MacCallum, C.J.; Stang, P.D.

    1985-01-01

    High resolution gamma-ray spectroscopy is a relatively new field that holds great promise for further understanding of high energy astrophysical processes. Preliminary results such as the annihilation radiation from the galactic center, the 26 Al line from the galactic plane and cyclotron lines from neutron stars may well be just the initial discoveries of a rich and as yet undeveloped field. When the high resolution gamma-ray spectrometer (GRSE) was removed from the GRO payload NASA decided to initiate a balloon program to permit continued development and improvement of instrumentation in this field, as well as continued scientific observations. The Gamma-Ray Imaging Spectrometer (GRIS) is one of the experiments selected as part of this program. The instrument contains a number of new and innovative features that are expected to produce a significant improvement in source location accuracy and sensitivity over previous balloon and satellite experiments. 6 refs., 2 figs

  17. Calibration of Ge gamma-ray spectrometers for complex sample geometries and matrices

    Energy Technology Data Exchange (ETDEWEB)

    Semkow, T.M., E-mail: thomas.semkow@health.ny.gov [Wadsworth Center, New York State Department of Health, Empire State Plaza, Albany, NY 12201 (United States); Department of Environmental Health Sciences, School of Public Health, University at Albany, State University of New York, Rensselaer, NY 12144 (United States); Bradt, C.J.; Beach, S.E.; Haines, D.K.; Khan, A.J.; Bari, A.; Torres, M.A.; Marrantino, J.C.; Syed, U.-F. [Wadsworth Center, New York State Department of Health, Empire State Plaza, Albany, NY 12201 (United States); Kitto, M.E. [Wadsworth Center, New York State Department of Health, Empire State Plaza, Albany, NY 12201 (United States); Department of Environmental Health Sciences, School of Public Health, University at Albany, State University of New York, Rensselaer, NY 12144 (United States); Hoffman, T.J. [Wadsworth Center, New York State Department of Health, Empire State Plaza, Albany, NY 12201 (United States); Curtis, P. [Kiltel Systems, Inc., Clyde Hill, WA 98004 (United States)

    2015-11-01

    A comprehensive study of the efficiency calibration and calibration verification of Ge gamma-ray spectrometers was performed using semi-empirical, computational Monte-Carlo (MC), and transfer methods. The aim of this study was to evaluate the accuracy of the quantification of gamma-emitting radionuclides in complex matrices normally encountered in environmental and food samples. A wide range of gamma energies from 59.5 to 1836.0 keV and geometries from a 10-mL jar to 1.4-L Marinelli beaker were studied on four Ge spectrometers with the relative efficiencies between 102% and 140%. Density and coincidence summing corrections were applied. Innovative techniques were developed for the preparation of artificial complex matrices from materials such as acidified water, polystyrene, ethanol, sugar, and sand, resulting in the densities ranging from 0.3655 to 2.164 g cm{sup −3}. They were spiked with gamma activity traceable to international standards and used for calibration verifications. A quantitative method of tuning MC calculations to experiment was developed based on a multidimensional chi-square paraboloid. - Highlights: • Preparation and spiking of traceable complex matrices in extended geometries. • Calibration of Ge gamma spectrometers for complex matrices. • Verification of gamma calibrations. • Comparison of semi-empirical, computational Monte Carlo, and transfer methods of Ge calibration. • Tuning of Monte Carlo calculations using a multidimensional paraboloid.

  18. Calibration of Ge gamma-ray spectrometers for complex sample geometries and matrices

    International Nuclear Information System (INIS)

    Semkow, T.M.; Bradt, C.J.; Beach, S.E.; Haines, D.K.; Khan, A.J.; Bari, A.; Torres, M.A.; Marrantino, J.C.; Syed, U.-F.; Kitto, M.E.; Hoffman, T.J.; Curtis, P.

    2015-01-01

    A comprehensive study of the efficiency calibration and calibration verification of Ge gamma-ray spectrometers was performed using semi-empirical, computational Monte-Carlo (MC), and transfer methods. The aim of this study was to evaluate the accuracy of the quantification of gamma-emitting radionuclides in complex matrices normally encountered in environmental and food samples. A wide range of gamma energies from 59.5 to 1836.0 keV and geometries from a 10-mL jar to 1.4-L Marinelli beaker were studied on four Ge spectrometers with the relative efficiencies between 102% and 140%. Density and coincidence summing corrections were applied. Innovative techniques were developed for the preparation of artificial complex matrices from materials such as acidified water, polystyrene, ethanol, sugar, and sand, resulting in the densities ranging from 0.3655 to 2.164 g cm −3 . They were spiked with gamma activity traceable to international standards and used for calibration verifications. A quantitative method of tuning MC calculations to experiment was developed based on a multidimensional chi-square paraboloid. - Highlights: • Preparation and spiking of traceable complex matrices in extended geometries. • Calibration of Ge gamma spectrometers for complex matrices. • Verification of gamma calibrations. • Comparison of semi-empirical, computational Monte Carlo, and transfer methods of Ge calibration. • Tuning of Monte Carlo calculations using a multidimensional paraboloid

  19. Elpasolite Planetary Ice and Composition Spectrometer (EPICS): A Low-Resource Combined Gamma-Ray and Neutron Spectrometer for Planetary Science

    Science.gov (United States)

    Stonehill, L. C.; Coupland, D. D. S.; Dallmann, N. A.; Feldman, W. C.; Mesick, K.; Nowicki, S.; Storms, S.

    2017-12-01

    The Elpasolite Planetary Ice and Composition Spectrometer (EPICS) is an innovative, low-resource gamma-ray and neutron spectrometer for planetary science missions, enabled by new scintillator and photodetector technologies. Neutrons and gamma rays are produced by cosmic ray interactions with planetary bodies and their subsequent interactions with the near-surface materials produce distinctive energy spectra. Measuring these spectra reveals details of the planetary near-surface composition that are not accessible through any other phenomenology. EPICS will be the first planetary science instrument to fully integrate the neutron and gamma-ray spectrometers. This integration is enabled by the elpasolite family of scintillators that offer gamma-ray spectroscopy energy resolutions as good as 3% FWHM at 662 keV, thermal neutron sensitivity, and the ability to distinguish gamma-ray and neutron signals via pulse shape differences. This new detection technology will significantly reduce size, weight, and power (SWaP) while providing similar neutron performance and improved gamma energy resolution compared to previous scintillator instruments, and the ability to monitor the cosmic-ray source term. EPICS will detect scintillation light with silicon photomultipliers rather than traditional photomultiplier tubes, offering dramatic additional SWaP reduction. EPICS is under development with Los Alamos National Laboratory internal research and development funding. Here we report on the EPICS design, provide an update on the current status of the EPICS development, and discuss the expected sensitivity and performance of EPICS in several potential missions to airless bodies.

  20. Design and applications of an anticoincidence shielded low background gamma-ray spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Petri, H [Forschungszentrum Juelich GmbH (Germany). Zentralabteilung fuer Chemische Analysen

    1997-03-01

    A low background gamma-ray spectrometer has been constructed for measuring artificial and natural radioative isotopes. The design of the spectrometer, its properties and the application to the determination of natural radioactivity of dental ceramics are described. (orig.)

  1. Mercuric Iodide Anticoincidence Shield for Gamma-Ray Spectrometer, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — We utilize a new detector material, polycrystalline mercuric iodide, for background suppression by active anticoincidence shielding in gamma-ray spectrometers. Two...

  2. SWEPP gamma-ray spectrometer system software user's guide

    International Nuclear Information System (INIS)

    Femec, D.A.

    1994-08-01

    The SWEPP Gamma-Ray Spectrometer (SGRS) System has been developed by the Radiation Measurement and Development Unit of the Idaho National Engineering Laboratory to assist in the characterization of the radiological contents of contact-handled waste containers at the Stored Waste Examination Pilot Plant (SWEPP). In addition to determining the concentrations of gamma-ray-emitting radionuclides, the software also calculates attenuation-corrected isotopic mass ratios of specific interest, and provides controls for SGRS hardware as required. This document serves as a user's guide for the data acquisition and analysis software associated with the SGRS system

  3. Ultra-Wideband Optical Modulation Spectrometer (OMS) Development

    Science.gov (United States)

    Gardner, Jonathan (Technical Monitor); Tolls, Volker

    2004-01-01

    The optical modulation spectrometer (OMS) is a novel, highly efficient, low mass backend for heterodyne receiver systems. Current and future heterodyne receiver systems operating at frequencies up to a few THz require broadband spectrometer backends to achieve spectral resolutions of R approximately 10(exp 5) to 10(exp 6) to carry out many important astronomical investigations. Among these are observations of broad emission and absorption lines from extra-galactic objects at high redshifts, spectral line surveys, and observations of planetary atmospheres. Many of these lines are pressure or velocity broadened with either large half-widths or line wings extending over several GHz. Current backend systems can cover the needed bandwidth only by combining the output of several spectrometers, each with typically up to 1 GHz bandwidth, or by combining several frequency-shifted spectra taken with a single spectrometer. An ultra-wideband optical modulation spectrometer with 10 - 40 GHz bandwidth will enable broadband ob- servations without the limitations and disadvantages of hybrid spectrometers. Spectrometers like the OMS will be important for both ground-based observatories and future space missions like the Single Aperture Far-Infrared Telescope (SAFIR) which might carry IR/submm array heterodyne receiver systems requiring a spectrometer for each array pixel. Small size, low mass and small power consumption are extremely important for space missions. This report summarizes the specifications developed for the OMS and lists already identified commercial parts. The report starts with a review of the principle of operation, then describes the most important components and their specifications which were derived from theory, and finishes with a conclusion and outlook.

  4. Determination of correction and conversion factor of exposure rate generated Gamma spectrometer GR-320 to Victoreen data

    International Nuclear Information System (INIS)

    Supardjo-AS; Mappa, Djody-Rachim; Nasrun-Syamsul; Syamsul-Hadi

    2000-01-01

    Exposure rate data of Muria Peninsula were generated from Victoreen-491 measurement and calculation of radioelement content in soil which were measured by Exploranium GR-320, using IAEA formula. However those data are not be comparable so the exposure rate calculated from Gamma Spectrometer data necessarily to be corrected. The correction factor was determinate by measuring the exposure rate of at the NMDC's back yard selected location using Victoreen-491 and Gamma Spectrometer Exploranium GR-320 . Correction factor was created by comparing mean exposure rate data that calculated from 30 data measured by Gamma Spectrometer instrument and to those Victoreen's exposure rate. Conversion factor was gained from comparing of total count data of Gamma Spectrometer Exploranium GR-320 to Victoreen's exposure rate data. The correction factor of Exploranium GR-320's exposure rate is 0.34 μR/hours, and the conversion factor of total count is 0.0092 μR/hours per c/m. Deviation Victoreen 491 = 4.7 % and Gamma Spectrometer Exploranium GR-320 8.6 %

  5. Spectrum analysis with indoor multi-channels gamma-rays spectrometer (NaI(Tl))

    International Nuclear Information System (INIS)

    Hou Shengli; Fan Weihua

    2005-01-01

    Two calculational methods for analyzing the spectrum which measured by indoor low background multi-channels gamma-rays spectrometer (Na(Tl)) to get the specific activity of 226 Ra, 232 Th and 40 K of the sample are discussed, they are the spectrum analysis method and the characteristic energy peak method (inverse matrix method) respectively. The sample spectrum are analyzed with the program designed according to the two methods, and compared with the results by HPGe gamma-rays spectrometer, showing that the relative deviation is ≤10% with the two methods. (authors)

  6. Determination of radionuclides for river sediment CRM with HPGe gamma-ray spectrometer

    International Nuclear Information System (INIS)

    Tan Jinbo; Hao Runlong; Tang Zhenxin

    1994-01-01

    The authors described the method and results for determination of seven radionuclides: 238 U, 235 U, 226 Ra, 232 Th, 40 K, 60 Co and 137 Cs in the river sediment Certified Reference Material (CRM) using a HPGe gamma-ray spectrometer. The accuracy and reliability of measurement results were improved through varieties of techniques, which include: precise calibration of the gamma-ray spectrometer, coincidence summing correction and interference peak correction, two kinds of peak analysis methods (TPA and function fit), and utilization of as many as possible characteristic gamma-rays. Present measurement results for the seven radionuclides were in agreement with the verification results of the CRM with 1 σ or 2σ uncertainty, and its relative deviation were in the range of +1.0%--6.5%

  7. Tandem collimators for the JET tangential gamma-ray spectrometer

    International Nuclear Information System (INIS)

    Soare, Sorin; Balshaw, Nick; Blanchard, Patrick; Craciunescu, Teddy; Croft, David; Curuia, Marian; Edlington, Trevor; Kiptily, Vasily; Murari, Andrea; Prior, Phil; Sanders, Steven; Syme, Brian; Zoita, Vasile

    2011-01-01

    The tangential gamma-ray spectrometer (TGRS) of the JET tokamak fusion facility is an important diagnostics for investigating the fast particle evolution. A well defined field of view for the TGRS diagnostics is essential for its proper operation and this is to be determined by a rather complex system of collimators and shields both for the neutron and gamma radiations. A conceptual design for this system has been carried out with the main design target set to maximize the signal-to-background ratio at the spectrometer detector, the ratio being defined in terms of the plasma emitted gamma radiation and the gamma-ray background. As a first phase of the TGRS diagnostics upgrade a set of two tandem collimators has been designed with the aim of determining a quasi-tangential field of view through JET tokamak plasmas. A modular design of the tandem system has been developed in order to allow for the construction of different configurations for deuterium and deuterium-tritium discharges. The internal structure of the collimators consists of nuclear grade lead and high density polyethylene slabs arranged in an optimized pattern. The performance of a simplified geometry of the tandem collimator configuration has been evaluated by neutron and photon transport calculations and the numerical results show that the design parameters can be attained.

  8. Combined, solid-state molecular property and gamma spectrometers for CBRNE detection

    Science.gov (United States)

    Rogers, Ben; Grate, Jay; Pearson, Brett; Gallagher, Neal; Wise, Barry; Whitten, Ralph; Adams, Jesse

    2013-05-01

    Nevada Nanotech Systems, Inc. (Nevada Nano) has developed a multi-sensor solution to Chemical, Biological, Radiological, Nuclear and Explosives (CBRNE) detection that combines the Molecular Property Spectrometer™ (MPS™)—a micro-electro-mechanical chip-based technology capable of measuring a variety of thermodynamic and electrostatic molecular properties of sampled vapors and particles—and a compact, high-resolution, solid-state gamma spectrometer module for identifying radioactive materials, including isotopes used in dirty bombs and nuclear weapons. By conducting multiple measurements, the system can provide a more complete characterization of an unknown sample, leading to a more accurate identification. Positive identifications of threats are communicated using an integrated wireless module. Currently, system development is focused on detection of commercial, military and improvised explosives, radioactive materials, and chemical threats. The system can be configured for a variety of CBRNE applications, including handheld wands and swab-type threat detectors requiring short sample times, and ultra-high sensitivity detectors in which longer sampling times are used. Here we provide an overview of the system design and operation and present results from preliminary testing.

  9. SWEPP Gamma-Ray Spectrometer System software design description

    International Nuclear Information System (INIS)

    Femec, D.A.; Killian, E.W.

    1994-08-01

    To assist in the characterization of the radiological contents of contract-handled waste containers at the Stored Waste Examination Pilot Plant (SWEPP), the SWEPP Gamma-Ray Spectrometer (SGRS) System has been developed by the Radiation Measurements and Development Unit of the Idaho National Engineering Laboratory. The SGRS system software controls turntable and detector system activities. In addition to determining the concentrations of gamma-ray-emitting radionuclides, this software also calculates attenuation-corrected isotopic mass ratios of-specific interest. This document describes the software design for the data acquisition and analysis software associated with the SGRS system

  10. SWEPP Gamma-Ray Spectrometer System software design description

    Energy Technology Data Exchange (ETDEWEB)

    Femec, D.A.; Killian, E.W.

    1994-08-01

    To assist in the characterization of the radiological contents of contract-handled waste containers at the Stored Waste Examination Pilot Plant (SWEPP), the SWEPP Gamma-Ray Spectrometer (SGRS) System has been developed by the Radiation Measurements and Development Unit of the Idaho National Engineering Laboratory. The SGRS system software controls turntable and detector system activities. In addition to determining the concentrations of gamma-ray-emitting radionuclides, this software also calculates attenuation-corrected isotopic mass ratios of-specific interest. This document describes the software design for the data acquisition and analysis software associated with the SGRS system.

  11. Discuss the technology for decrease the detection limit of NaI(Tl) gamma spectrometer

    International Nuclear Information System (INIS)

    Guo Xiaobin; Qu Guopu; Liu Zhiying; Wang Hongyan; Wang Lieming

    2011-01-01

    The radioelement species is complex and quantity is few after nuclear explosion, thus it is hard to tell the difference when using the Nal (TI) Gamma spectrometer detection due to several kinds of the peak of nuclide overlapped in the scattering region. So there is a high demand for spectrometer stability, energy resolution, solution spectrum and minimum detective activity. The paper analysed the influenced factors to Nal (TI) Gamma spectrometer and the measures of detection limit decrease by experiments and MCNP simulation, which proposed the methods to reduce background through shielding in order to improve minimum detective activity. The experiment shows that choosing reasonable shielding can reduce the background effectively and improve the spectrometer low level radioactive detect ability. (authors)

  12. Calculation Analysis of Calibration Factors of Airborne Gamma-ray Spectrometer

    International Nuclear Information System (INIS)

    Zhao Jun; Zhu Jinhui; Xie Honggang; He Qinglin

    2009-01-01

    To determine the calibration factors of an airborne gamma-ray spectrometer measuring large area gamma-ray emitting source at deferent flying height, a series of Monte Carlo simulations were drawn. Response energy spectrums of NaI crystals in airplane caused by nature-decay-series calibration-pads, and calibration factors on different heights above Cs-137 plane source, were obtained. The calculated results agreed with the experimental data well. (authors)

  13. Initial studies of the gamma resonance of the 109mAg isomer with a gravitational gamma spectrometer

    International Nuclear Information System (INIS)

    Alpatov, V. G.; Bayukov, Yu. D.; Davydov, A. V.; Isaev, Yu. N.; Kartashov, G. R.; Korotkov, M. M.; Migachev, V. V.

    2008-01-01

    The problem of observing the Moessbauer resonance absorption of gamma rays from long-lived isomers is briefly outlined, first and foremost for 109m Ag taken as an example. Experiments indicative of a small broadening of the Moessbauer gamma line of this isomer in metallic silver are described. This circumstance made it possible to develop and manufacture a gravitational gamma spectrometer and to perform the first experiments with it, which confirm once again the previous data on a small width of the gamma line in question. The broadening factor obtained from these data proved to be 6.3 -1.9 +5.2 .

  14. The gamma ray spectrometer GA.SP

    Energy Technology Data Exchange (ETDEWEB)

    Bazzacco, D [Instituto Nazionale di Fisica Nucleare, Sezione di Padova, Padova (Italy)

    1992-08-01

    GA.SP is a general purpose 4{pi} detector array for advanced {gamma}-spectroscopy and, in the same time, a suitable system for reaction mechanism studies. The detector is sited at the LNL Tandem+Linac accelerator and has been built as a joint project of INFN Padova, LNL, Milano and Firenze. The array consists of 40 Compton suppressed HPGe detectors and of a 4{pi} calorimeter composed of 80 BGO crystals. The detector houses a reaction chamber of 34 cm diameter where a charged particles multiplicity filter composed of 40 Si detectors is going to be installed. Evaporation residues produced in the centre of GA.SP can be injected into the recoil mass spectrometer (RMS, named CAMEL) in use at LNL, without the need to remove any of the gamma detectors. The coupled operation of GA.SP, RMS and Si ball will give a unique instrument for identification and study of weak reaction channels. (author). 6 figs.

  15. Properties of a large NaI(Tl) spectrometer for the energy measurement of high-energy gamma rays on the Gamma Ray Observatory

    International Nuclear Information System (INIS)

    Hughes, E.B.; Finman, L.C.; Hofstadter, R.; Lepetich, J.E.; Lin, Y.C.; Mattox, J.R.; Nolan, P.L.; Parks, R.; Walker, A.H.

    1986-01-01

    A large NaI(T1) spectrometer is expected to play a crucial role in the measurement of the energy spectra from an all-sky survey of high-energy celestial gamma rays on the Gamma Ray Observatory. The crystal size and requirements of space flight have resulted in a novel crystal-packaging and optics combination. The structure of this spectrometer and the operating characteristics determined in a test program using high energy positrons are described

  16. Determination of correction factor of radioelement content data generated from Exploranium GR-320 Gamma spectrometer

    International Nuclear Information System (INIS)

    Nasrun, S; Syamsul-Hadi, M; Sumardi

    2000-01-01

    Gamma-ray Spectrometer Exploranium GR-320 is the instrument radiometric survey which is able to measure radioelement content directly in field based on partial gamma-ray energy of elements. Because of the instrument is new and it was granted from the lAEA, so it is necessarily to create a correction factor for the instrument due to be gaining the better data. Correction factor was generated from comparing gamma spectrometer's radioelement content to those of chemical analysed data of calibration pad. The correction factor for Potassium (K) is 1.31, uranium is 1.46, and thorium is 0.39

  17. Comparisons between digital gamma-ray spectrometer (DSPec) and standard nuclear instrumentation methods (NIM) systems

    International Nuclear Information System (INIS)

    Vo, D.T.; Russo, P.A.; Sampson, T.E.

    1998-03-01

    Safeguards isotopic measurements require the best spectrometer systems with excellent resolution, stability and throughput. Up until about a year ago, gamma ray spectroscopy has always been done using the analog amplifier, which processes the pulses from the preamplifier to remove the noise, reject the pile up signals, and shape the signals into some desirable form before sending them to the analog to digital converter (ADC) to be digitized. In late 1996, EG and G Ortec introduced a digital gamma ray spectrometer (DSPec) which uses digital technology to analyze the preamplifiers' pulses from all types of germanium and silicon detectors. Considering its performance, digital based spectroscopy may become the way of future gamma ray spectroscopy

  18. Search for gamma-ray transients using the SMM spectrometer

    Science.gov (United States)

    Share, G. H.; Harris, M. J.; Leising, M. D.; Messina, D. C.

    1993-01-01

    Observations for transient radiation made by the Gamma Ray Spectrometer on the SMM satellite are summarized. Spectra were obtained from 215 solar flares and 177 gamma-ray bursts. No narrow or moderately broadened lines were observed in any of the bursts. The rate of bursts is consistent with a constant over the mission but is weakly correlated with solar activity. No evidence was found for bursts of 511 keV line emission, unaccompanied by a strong continuum, at levels not less than 0.05 gamma/sq cm s for bursts lasting not more than 16 s. No evidence was found for broad features near 1 MeV from Cyg X-1, the Galactic center, or the Crab in 12-d integrations at levels not less than 0.006 gamma/sq cm s. No evidence was found for transient celestial narrow-line emission from 300 keV to 7 MeV on min-to-hrs-long time scales from 1984 to 1989.

  19. TIGRESS: TRIUMF-ISAC gamma-ray escape-suppressed spectrometer

    Science.gov (United States)

    Svensson, C. E.; Amaudruz, P.; Andreoiu, C.; Andreyev, A.; Austin, R. A. E.; Ball, G. C.; Bandyopadhyay, D.; Boston, A. J.; Chakrawarthy, R. S.; Chen, A. A.; Churchman, R.; Drake, T. E.; Finlay, P.; Garrett, P. E.; Grinyer, G. F.; Hackman, G.; Hyland, B.; Jones, B.; Kanungo, R.; Maharaj, R.; Martin, J. P.; Morris, D.; Morton, A. C.; Pearson, C. J.; Phillips, A. A.; Ressler, J. J.; Roy, R.; Sarazin, F.; Schumaker, M. A.; Scraggs, H. C.; Smith, M. B.; Starinsky, N.; Valiente-Dobón, J. J.; Waddington, J. C.; Watters, L. M.

    2005-10-01

    The TRIUMF-ISAC gamma-ray escape-suppressed spectrometer (TIGRESS) is a new γ-ray detector array being developed for use at TRIUMF's Isotope Separator and Accelerator (ISAC) radioactive ion beam facility. TIGRESS will comprise 12 32-fold segmented clover-type HPGe detectors coupled with 20-fold segmented modular Compton suppression shields and custom digital signal processing electronics. This paper provides an overview of the TIGRESS project and progress in its development to date.

  20. The dynamic range of ultra-high-resolution cryogenic gamma-ray spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    Ali, Shafinaz [Advanced Detector Group, Lawrence Livermore National Laboratory, 7000 East Avenue, L-270, Livermore, CA 94550 (United States); Terracol, Stephane F. [Advanced Detector Group, Lawrence Livermore National Laboratory, 7000 East Avenue, L-270, Livermore, CA 94550 (United States); Drury, Owen B. [Advanced Detector Group, Lawrence Livermore National Laboratory, 7000 East Avenue, L-270, Livermore, CA 94550 (United States); Friedrich, Stephan [Advanced Detector Group, Lawrence Livermore National Laboratory, 7000 East Avenue, L-270, Livermore, CA 94550 (United States)]. E-mail: friedrich1@llnl.gov

    2006-04-15

    We are developing high-resolution cryogenic gamma-ray spectrometers for nuclear science and non-proliferation applications. The gamma-ray detectors are composed of a bulk superconducting Sn foil absorber attached to a multilayer Mo/Cu transition-edge sensor (TES). The energy resolution of a detector with a 1x1x0.25 mm{sup 3} Sn absorber is 50-90 eV FWHM for {gamma}-rays up to 100 keV, and it decreases for larger absorbers. Here, we present the detector performance for different absorber volumes, and discuss the trade-offs between energy resolution and dynamic range.

  1. Observations of Galactic gamma-radiation with the SMM spectrometer

    Science.gov (United States)

    Share, G. H.; Kinzer, R. L.; Messina, D. C.; Purcell, W. R.; Chupp, E. L.

    1986-01-01

    Preliminary results from the SMM gamma-ray spectrometer are reported which indicate the detection of a constant source of 0.511-MeV annihilation radiation from the Galaxy. Year-to-year variability appears to be less than 30 percent. The radiation probably comes from a diffuse source and is not associated with the reported compact object at the Galactic center.

  2. Study of the functional characteristics of a NaI(Tl) scintillator gamma spectrometer

    International Nuclear Information System (INIS)

    Jesus Barbosa, S. de.

    1983-01-01

    Functional characteristics (resolution, stability, linearity, counting efficiency) of a NaI(Tl) scintillator gamma spectrometer were studied. Diagrams were plotted and several standard sources ( 241 Am, 109 Cd, 57 Co, 137 Cs, 54 Mn, 22 Na) with gamma energies ranging from 60 to 1275 KeV were used. (C.L.B.) [pt

  3. Polarimetric Analysis of the Long Duration Gamma-Ray Burst GRB 160530A With the Balloon Borne Compton Spectrometer and Imager

    Energy Technology Data Exchange (ETDEWEB)

    Lowell, A. W.; Boggs, S. E; Chiu, C. L.; Kierans, C. A.; Sleator, C.; Tomsick, J. A.; Zoglauer, A. C. [Space Sciences Laboratory, University of California, Berkeley (United States); Chang, H.-K.; Tseng, C.-H.; Yang, C.-Y. [Institute of Astronomy, National Tsing Hua University, Taiwan (China); Jean, P.; Ballmoos, P. von [IRAP Toulouse (France); Lin, C.-H. [Institute of Physics, Academia Sinica, Taiwan (China); Amman, M. [Lawrence Berkeley National Laboratory (United States)

    2017-10-20

    A long duration gamma-ray burst, GRB 160530A, was detected by the Compton Spectrometer and Imager (COSI) during the 2016 COSI Super Pressure Balloon campaign. As a Compton telescope, COSI is inherently sensitive to the polarization of gamma-ray sources in the energy range 0.2–5.0 MeV. We measured the polarization of GRB 160530A using (1) a standard method (SM) based on fitting the distribution of azimuthal scattering angles with a modulation curve and (2) an unbinned, maximum likelihood method (MLM). In both cases, the measured polarization level was below the 99% confidence minimum detectable polarization levels of 72.3% ± 0.8% (SM) and 57.5% ± 0.8% (MLM). Therefore, COSI did not detect polarized gamma-ray emission from this burst. Our most constraining 90% confidence upper limit on the polarization level was 46% (MLM).

  4. One module of the ALICE photon spectrometer

    CERN Multimedia

    Maximilien Brice

    2006-01-01

    The first module for the ALICE photon spectrometer has been completed. Each of the five modules will contain 3584 lead-tungstate crystals, a material as transparent as ordinary silica glass but with nearly four times the density. When a high-energy particle passes through one of these crystals it will scintillate, allowing the energy of electrons, positrons and photons to be measured through the 17 920 detection channels.

  5. A gamma-spectrometer determining equilibrium factor in situ

    International Nuclear Information System (INIS)

    Feng Weiheng

    1992-01-01

    The author expounds main function, scientific value and practical significance of Model SY500 gamma-spectrometer, which can determine radioactive factor equilibrium (k p ) in-situ. Accuracy, steadiness and differential of the technology has been proved on the models of Radiometric Measurement Station of China Nuclear Industry Corporation. The author enumerates several examples such as k p survey at gold-bearing glebe, at uranium-bearing glebe, at the ground above ground water and 21 stations of Beijing subway

  6. An efficiency study of a high resolution gamma-ray spectrometer

    International Nuclear Information System (INIS)

    Marti Climent, J.M.

    1987-01-01

    A review of the different curves for the efficiency fit of a high resolution gamma-ray spectrometer was made. These curves are used to fit the efficiency of our detector system. In order to study the goodness of the different fits various standards were used, and the ICRP GAM-83 exercise results were employed. (author)

  7. Pocket PC-based portable gamma-ray spectrometer

    Directory of Open Access Journals (Sweden)

    Kamontip Ploykrachang

    2011-04-01

    Full Text Available A portable gamma-ray spectrometer based on a Pocket PC has been developed. A 12-bit pipeline analog-to-digitalconverter (ADC associated with an implemented pulse height histogram function on field programmable gate array (FPGAoperating at 15 MHz is employed for pulse height analysis from built-in pulse amplifier. The system, which interfaces withthe Pocket PC via an enhanced RS-232 serial port under the microcontroller facilitation, is utilized for spectrum acquisition,display and analysis. The pulse height analysis capability of the system was tested and it was found that the ADC integralnonlinearity of ±0.45% was obtained with the throughput rate at 160 kcps. The overall system performance was tested usinga PIN photodiode-CsI(Tl crystal coupled scintillation detector and gamma standard radioactive sources of Cs-137 andCo-60. Low cost and the compact system size as a result of the implemented logical function are also discussed.

  8. Use of a low-background and anti-Compton HpGe gamma-spectrometer in analyses of environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Qiong, Su; Yamin, Gao [Ministry of Public Health, Beijing, BJ (China). Lab. of Industrial Hygiene

    1989-12-01

    The results of application of a HpGe gamma-spectrometer in the analyses of enviromental samples are reported. The spectrometer has very low background and good property of Compton suppression. By comparison between the gamma-spectra with and without anti-coincidence shield for the same samples, the advantage in analysing environmental samples became apparent. In the analyses of carp samples, the ratio of specific activities of {sup 226}Ra in the flesh and bone of the carp was 1 to 35, which is basically in agreement with the ratio of the accumulation factors 1:37, as reported in the literature. Thus the spectrometer would play an important role in the research of the transfer of radionuclides of low activity in the environment. The method of gamma-ray data processing is also described.

  9. Use of a low-background and anti-Compton HpGe gamma-spectrometer in analyses of environmental samples

    International Nuclear Information System (INIS)

    Su Qiong; Gao Yamin

    1989-01-01

    The results of application of a HpGe gamma-spectrometer in the analyses of enviromental samples are reported. The spectrometer has very low background and good property of Compton suppression. By comparison between the gamma-spectra with and without anti-coincidence shield for the same samples, the advantage in analysing environmental samples became apparent. In the analyses of carp samples, the ratio of specific activities of 226 Ra in the flesh and bone of the carp was 1 to 35, which is basically in agreement with the ratio of the accumulation factors 1:37, as reported in the literature. Thus the spectrometer would play an important role in the research of the transfer of radionuclides of low activity in the environment. The method of gamma-ray data processing is also described

  10. A high resolution gamma-ray spectrometer based on superconducting microcalorimeters

    Energy Technology Data Exchange (ETDEWEB)

    Bennett, D. A.; Horansky, R. D. [National Institute of Standards and Technology, Boulder, Colorado 80305 (United States); University of Denver, Denver, Colorado 80208 (United States); Schmidt, D. R.; Doriese, W. B.; Fowler, J. W.; Kotsubo, V.; Mates, J. A. B. [National Institute of Standards and Technology, Boulder, Colorado 80305 (United States); University of Colorado, Boulder, Colorado 80309 (United States); Hoover, A. S.; Winkler, R.; Rabin, M. W. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Alpert, B. K.; Beall, J. A.; Fitzgerald, C. P.; Hilton, G. C.; Irwin, K. D.; O' Neil, G. C.; Reintsema, C. D.; Schima, F. J.; Swetz, D. S.; Vale, L. R. [National Institute of Standards and Technology, Boulder, Colorado 80305 (United States); and others

    2012-09-15

    Improvements in superconductor device fabrication, detector hybridization techniques, and superconducting quantum interference device readout have made square-centimeter-sized arrays of gamma-ray microcalorimeters, based on transition-edge sensors (TESs), possible. At these collecting areas, gamma microcalorimeters can utilize their unprecedented energy resolution to perform spectroscopy in a number of applications that are limited by closely-spaced spectral peaks, for example, the nondestructive analysis of nuclear materials. We have built a 256 pixel spectrometer with an average full-width-at-half-maximum energy resolution of 53 eV at 97 keV, a useable dynamic range above 400 keV, and a collecting area of 5 cm{sup 2}. We have demonstrated multiplexed readout of the full 256 pixel array with 236 of the pixels (91%) giving spectroscopic data. This is the largest multiplexed array of TES microcalorimeters to date. This paper will review the spectrometer, highlighting the instrument design, detector fabrication, readout, operation of the instrument, and data processing. Further, we describe the characterization and performance of the newest 256 pixel array.

  11. SWEPP gamma-ray spectrometer system software test plan and report

    International Nuclear Information System (INIS)

    Femec, D.A.

    1994-09-01

    The SWEPP Gamma-Ray Spectrometer (SGRS) System has been developed by the Radiation Measurements and Development Unit of the Idaho National Engineering Laboratory to assist in the characterization of the radiological contents of contact-handled waste containers at the Stored Waste Examination Pilot Plant (SWEPP). In addition to determining the concentrations of gamma-ray-emitting radionuclides, the software also calculates attenuation-corrected isotopic mass ratios of specific interest, and provides controls for SGRS hardware as required. This document presents the test plan and report for the data acquisition and analysis software associated with the SGRS system

  12. Ultralow background germanium gamma-ray spectrometer using superclean materials and cosmic-ray anticoincidence

    International Nuclear Information System (INIS)

    Reeves, J.H.; Hensley, W.K.; Brodzinski, R.L.; Ryge, P.

    1983-10-01

    Efforts to measure the double beta decay of 76 Ge as predicted by Grand Unified Theories have resulted in the development of a high resolution germanium diode gamma-ray spectrometer with an exceptionally low background. This paper describes the development of this system and how these techniques can be utilized to significantly reduce the background in high resolution photon spectrometers at only a moderate cost

  13. Ultra-Wideband Optical Modulation Spectrometer (OMS) Development: Study of the Optical Setup of a Wide-Band Optical Modulation Spectrometer

    Science.gov (United States)

    Tolls, Volker; Stringfellow, Guy (Technical Monitor)

    2001-01-01

    The purpose of this study is to advance the design of the optical setup for a wide-band Optical Modulation Spectrometer (OMS) for use with astronomical heterodyne receiver systems. This report describes the progress of this investigation achieved from March until December 2001.

  14. Validation of gamma spectrometer in spectroscopy laboratory of education and training center BATAN

    International Nuclear Information System (INIS)

    Sugino; Tulisna; Anda Sanusi; Sugito

    2010-01-01

    Gamma spectrometer used to determine the type and activity of gamma emitting radionuclides, such as the measurement of environmental radioactivity and neutron activation analysis (NAA). In order to obtain precise and accurate qualitative and quantitative analysis, the gamma spectrometer should be validated. Validation of the gamma spectrometer was conducted on the confirmation of identity, differential linearity, performance, efficiency calibration, precision test, and accuracy test. Confirmation of identity conducted by energy calibration testing conducted and showed the largest energy deviation of 0.3 keV. Differential linearity testing showed the highest count difference of 6.9 %. Test Results for 1 year showed the lowest resolution of 1.82 keV, in accordance with the initial resolution of 1.8 keV. Value of lowest P/C is 59.8, according to the first P/C of 60. The lowest relative efficiency of 28.6 %, according to the initial efficiency of 30 %. Calibration curve shows that for more than 200 keV energy, the relationship of Ln Energy vs Ln Efficiency is a straight line with equation Ln(ε) = 7.211-0.8173 Ln(E), while for less than 100 keV energy the the equation Ln(ε) = -13.34+6.712Ln(E)+0.06894 Ln(E)"2, in accordance with the theory and references. Precision test conducted by chi square value of 10.6, according to probability of 5 % to 95 %. Testing the accuracy is shown from the results of comparative tests of measuring I-131 activity in 2009 with good results, the difference in the results of 2.35 % with the uncertainty of 6 %. (author)

  15. Tests of the space gamma spectrometer prototype at the JINR experimental facility with different types of neutron generators

    Science.gov (United States)

    Litvak, M. L.; Vostrukhin, A. A.; Golovin, D. V.; Dubasov, P. V.; Zontikov, A. O.; Kozyrev, A. S.; Krylov, A. R.; Krylov, V. A.; Mitrofanov, I. G.; Mokrousov, M. I.; Repkin, A. N.; Timoshenko, G. N.; Udovichenko, K. V.; Shvetsov, V. N.

    2017-07-01

    The results of the tests of the HPGe gamma spectrometer performed with a planetary soil model and different types of pulse neutron generators are presented. All measurements have been performed at the experimental nuclear planetary science facility (Joint Institute for Nuclear Research) for the physical calibration of active gamma and neutron spectrometers. The aim of the study is to model a space experiment on determining the elemental composition of Martian planetary matter by neutron-induced gamma spectroscopy. The advantages and disadvantages of a gas-filled neutron generator in comparison with a vacuum-tube neutron generator are examined.

  16. The Dynamic Range of Ultra-High Resolution Cryogenic Gamma-ray Spectrometers

    International Nuclear Information System (INIS)

    Ali, S; Terracol, S F; Drury, O B; Friedrich, S

    2005-01-01

    We are developing high-resolution cryogenic gamma-ray spectrometers for nuclear science and non-proliferation applications. The gamma-ray detectors are composed of a bulk superconducting Sn foil absorber attached to multilayer Mo/Cu transition-edge sensors (TES). The energy resolution achieved with a 1 x 1 x 0.25 mm 3 Sn absorber is 50 -90eV for γ-rays up to 100 keV and it decreases for large absorber sizes. We discuss the trade-offs between energy resolution and dynamic range, as well as development of TES arrays for higher count rates and better sensitivity

  17. Characteristics of bursts observed by the SMM Gamma-Ray Spectrometer

    Science.gov (United States)

    Share, G. H.; Messina, D. C.; Iadicicco, A.; Matz, S. M.; Rieger, E.; Forrest, D. J.

    1992-01-01

    The Gamma Ray Spectrometer (GRS) on the SMM completed close to 10 years of highly successful operation when the spacecraft reentered the atmosphere on December 2, 1989. During this period the GRS detected 177 events above 300 keV which have been classified as cosmic gamma-ray bursts. A catalog of these events is in preparation which will include time profiles and spectra for all events. Visual inspection of the spectra indicates that emission typically extends into the MeV range, without any evidence for a high-energy cutoff; 17 of these events are also observed above 10 MeV. We find no convincing evidence for line-like emission features in any of the time-integrated spectra.

  18. MESSENGER E/V/H GRNS 2 GAMMA RAY SPECTROMETER RAW DATA V1.0

    Data.gov (United States)

    National Aeronautics and Space Administration — Abstract ======== This data set consists of the MESSENGER GRS uncalibrated observations, also known as EDRs. The GRS experiment is a gamma ray spectrometer designed...

  19. Instrumental and atmospheric background lines observed by the SMM gamma-ray spectrometer

    Science.gov (United States)

    Share, G. H.; Kinzer, R. L.; Strickman, M. S.; Letaw, J. R.; Chupp, E. L.

    1989-01-01

    Preliminary identifications of instrumental and atmospheric background lines detected by the gamma-ray spectrometer on NASA's Solar Maximum Mission satellite (SMM) are presented. The long-term and stable operation of this experiment has provided data of high quality for use in this analysis. Methods are described for identifying radioactive isotopes which use their different decay times. Temporal evolution of the features are revealed by spectral comparisons, subtractions, and fits. An understanding of these temporal variations has enabled the data to be used for detecting celestial gamma-ray sources.

  20. Wireless, low-cost, FPGA-based miniature gamma ray spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Becker, E.M., E-mail: beckere@engr.orst.edu; Farsoni, A.T.

    2014-10-11

    A compact, low-cost, wireless gamma-ray spectrometer is a tool sought by a number of different organizations in the field of radiation detection. Such a device has applications in emergency response, battlefield assessment, and personal dosimetry. A prototype device fitting this description has been constructed in the Advanced Radiation Instrumentation Laboratory at Oregon State University. The prototype uses a CsI(Tl) scintillator coupled to a solid-state photomultiplier and a 40 MHz, 12-bit, FPGA-based digital pulse processor to measure gamma radiation, and is able to be accessed wirelessly by mobile phone. The prototype device consumes roughly 420 mW, weighs about 28 g (not including battery), and measures 2.54×3.81 cm{sup 2}. The prototype device is able to achieve 5.9% FWHM energy resolution at 662 keV.

  1. Environmental radioactivity measurements Using a compton suppression spectrometer

    International Nuclear Information System (INIS)

    Sharshar, T.; Elnimr, T.

    1998-01-01

    The natural and artificial radioactivities of some environmental samples such as soil and vegetables have been studied through gamma-ray spectroscopy with a new constructed compton suppression spectrometer (CSS). The spectrometer consists of a 10% p-type HPGe detector as a main detector, an annular NE-102 A plastic scintillator as a guard detector, and a fast-slow coincidence system employing standard electronic modules for anti-compton operation. This study shows that CSS is a powerful tool for measuring the low level activities of environmental samples

  2. Study on direct determination of uranium and efficient equilibrium factor by gamma-ray spectrometer

    International Nuclear Information System (INIS)

    Liu Chunkui

    1990-01-01

    The test principle, test set and surveying methods for conducting gamma-ray spectrometry on conveyer are presented. The conversion coefficient of the spectrometer has been found by using duallinear regression analysis of uranium and radon and their higher and lower bands of gamma-ray spectra. The efficient equilibrium factor can be quickly determined, and the direct determination of uranium in the non-equilibrium condition of uranium and radium can be made

  3. Thermal neutron detector and gamma-ray spectrometer utilizing a single material

    Science.gov (United States)

    Stowe, Ashley; Burger, Arnold; Lukosi, Eric

    2017-05-02

    A combined thermal neutron detector and gamma-ray spectrometer system, including: a detection medium including a lithium chalcopyrite crystal operable for detecting thermal neutrons in a semiconductor mode and gamma-rays in a scintillator mode; and a photodetector coupled to the detection medium also operable for detecting the gamma rays. Optionally, the detection medium includes a .sup.6LiInSe.sub.2 crystal. Optionally, the detection medium comprises a compound formed by the process of: melting a Group III element; adding a Group I element to the melted Group III element at a rate that allows the Group I and Group III elements to react thereby providing a single phase I-III compound; and adding a Group VI element to the single phase I-III compound and heating; wherein the Group I element includes lithium.

  4. An ultralow background germanium gamma-ray spectrometer

    International Nuclear Information System (INIS)

    Reeves, R.H.; Brodzinski, R.L.; Hensley, W.K.; Ryge, P.

    1984-01-01

    The monitoring of minimum detectable activity is becoming increasingly important as environmental concerns and regulations require more sensitive measurement of the radioactivity levels in the workplace and the home. In measuring this activity, however, the background becomes one of the limiting factors. Anticoincidence systems utilizing both NaI(T1) and plastic scintillators have proven effective in reducing some components of the background, but radiocontaminants in the various regions of these systems have limited their effectiveness, and their cost is often prohibitive. In order to obtain a genuinely low background detector system, all components must be free of detectable radioactivity, and the cosmic ray produced contribution must be significantly reduced. Current efforts by the authors to measure the double beta decay of Germanium 76 as predicted by Grand Unified Theories have resulted in the development of a high resolution germanium diode gamma spectrometer with an exceptionally low background. This paper describes the development of this system, outlines the configuration and operation of its preamplifier, linear amplifier, analog-to-digital converter, 4096-channel analyzer, shielding consisting of lead-sandwiched plastic scintillators wrapped in cadmium foil, photomultiplier, and its pulse generator and discriminator, and then discusses how the system can be utilized to significantly reduce the background in high resolution photon spectrometers at only moderate cost

  5. Reset charge sensitive amplifier for NaI(Tl) gamma-ray spectrometer

    International Nuclear Information System (INIS)

    Zeng, Guoqiang; Tan, Chengjun; Li, Qiang; Ge, Liangquan; Liu, Xiyao; Luo, Qun

    2015-01-01

    The time constant of the output signal of the front-end readout circuit of a traditional gamma-ray spectrometer with a NaI(Tl)+PMT structure is affected by temperature, measurement environment and the signal transmission cable, so it is difficult to get a good resolution spectrum, especially at higher counting rates. In this paper, a reset charge sensitive amplifier (RCSA) is designed for the gamma-ray spectrometer with a NaI(Tl)+PMT structure. The designed RCSA outputs a step signal, thus enabling the acquisition of double-exponential signals with a stable time constant by using the next stage of a CR differentiating circuit. The designed RCSA is mainly composed of a basic amplifying circuit, a reset circuit and a dark current compensation circuit. It provides the output step signal through the integration of the PMT output charge signal. When the amplitude of the step signal exceeds a preset voltage threshold, it triggers the reset circuit to generate a reset pulse (about 5 µs pulse width) to reset the output signal. Experimental results demonstrated that the designed RCSA achieves a charge sensitivity of 4.26×10 10 V/C, with a zero capacitance noise of 51.09 fC and a noise slope of 1.98 fC/pF. Supported by the digital shaping algorithm of the digital multi-channel analyzer (DMCA), it can maintain good energy resolution with high counting rates up to 150 kcps and with a temperature range from −19 °C to 50 °C. - Highlights: • A new reset type charge sensitive amplifier for gamma-ray spectrometer based on a photomultiplier tube is proposed. • Reset circuit formed by constant current source output a fixed width pulse to reset charge sensitive amplifier. • Photomultiplier tube dark current compensation circuit could increase the pulse through rate by decreasing reset frequency. • This amplifier outputs a step function signal that could match next stage circuit easily

  6. Gamma-Ray Imaging Spectrometer (GRIS) instrument and plans for serving SN 1987A

    International Nuclear Information System (INIS)

    Tueller, J.; Barthelmy, S.; Gehrels, N.; Teegarden, B.J.; Leventhal, M.; MacCallum, C.J.

    1988-01-01

    The Gamma-Ray Imaging Spectrometer (GRIS) is a powerful second-generation high-resolution gamma-ray spectrometer. It consists of an array of seven large (typically >200 cm 3 ) n-type Germanium detectors surrounded by a thick (15 m) NaI active shield. Its energy range is 0.02 to 10 MeV. A new detector segmentation technique will be employed to reduce the detector background. The β-decay background component, which is expected to be dominant in the 0.2--2 MeV range, will be suppressed by roughly a factor of 20. The 3σ GRIS sensitivity to a narrow Fe line at 847 keV (expected to be the most intense from a supernova) will be ∼2 x 10 -4 photons/cm 2 -s for an 8 hr observation of the LMC over Alice Springs, Australia with unsegmented detectors. The instrument in simplified form will be ready to observe SN 1987A in early 1988

  7. {gamma}-Ray background sources in the VESUVIO spectrometer at ISIS spallation neutron source

    Energy Technology Data Exchange (ETDEWEB)

    Pietropaolo, A. [CNISM Milano-Bicocca, Universita degli Studi di Milano-Bicocca, Dipartimento di Fisica ' G. Occhialini' , Piazza della Scienza 3, 20126 Milano (Italy); NAST Center (Nanoscienze-Nanotecnologie-Strumentazione), Universita degli Studi di Roma Tor Vergata, via della Ricerca Scientifica 1, 00133 Roma (Italy)], E-mail: antonino.pietropaolo@mib.infn.it; Perelli Cippo, E. [Universita degli Studi di Milano-Bicocca, Dipartimento di Fisica ' G. Occhialini' , Piazza della Scienza 3, 20126 Milano (Italy); Gorini, G. [CNISM Milano-Bicocca, Universita degli Studi di Milano-Bicocca, Dipartimento di Fisica ' G. Occhialini' , Piazza della Scienza 3, 20126 Milano (Italy); NAST Center (Nanoscienze-Nanotecnologie-Strumentazione), Universita degli Studi di Roma Tor Vergata, via della Ricerca Scientifica 1, 00133 Roma (Italy); Tardocchi, M. [Universita degli Studi di Milano-Bicocca, Dipartimento di Fisica ' G. Occhialini' , Piazza della Scienza 3, 20126 Milano (Italy); Schooneveld, E.M. [ISIS Facility, Rutherford Appleton Laboratory, Chilton, Didcot, Oxfordshire 0QX OX11 (United Kingdom); Andreani, C.; Senesi, R. [Universia degli Studi di Roma Tor Vergata, Dipartimento di Fisica and NAST Center (Nanoscienze-Nanotecnologie-Strumentazione), via della Ricerca Scientifica 1, 00133 Roma (Italy)

    2009-09-01

    An investigation of the gamma background was carried out in the VESUVIO spectrometer at the ISIS spallation neutron source. This study, performed with a yttrium-aluminum-perovskite (YAP) scintillator, follows high resolution pulse height measurements of the gamma background carried out on the same instrument with the use of a high-purity germanium detector. In this experimental work, a mapping of the gamma background was attempted, trying to find the spatial distribution and degree of directionality of the different contributions identified in the previous study. It is found that the gamma background at low times is highly directional and mostly due to the gamma rays generated in the moderator-decoupler system. The other contributions, consistently to the findings of a previous experiment, are identified as a nearly isotropic one due to neutron absorption in the walls of the experimental hall, and a directional one coming from the beam dump.

  8. Measurement Of I-131 In Air Using A Portable Gamma Spectrometer

    International Nuclear Information System (INIS)

    Bunawas; Dadong Iskandar; Wahyudi; U, Wiwik

    2000-01-01

    Aerosol contamination of I-131, radioactive emitting gamma radiation, can be directly measured by using a portable gamma spectrometer which used GC2020 Canberra HPGe detector. Assuming constant concentration of I-131 in the infinite space of semi spherical, calibration factor, and detection limits determined using standard CH 3 I gas. The results showed that the detection limits for 1 hour counting period was 3.06 Bq/m exp.3 for confidence level of 95% (2σ). Field measurements are conducted on several rooms with uncertainties variation between 0.34 and 60.11% compare with true values. Qualitative discussion of the factors contributing to the uncertainty in the in situ result is included

  9. Gamma-to-electron magnetic spectrometer (GEMS): An energy-resolved {gamma}-ray diagnostic for the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Y.; Herrmann, H. W.; Mack, J. M.; Young, C. S.; Barlow, D. B.; Schillig, J. B.; Sims, J. R. Jr.; Lopez, F. E.; Mares, D.; Oertel, J. A.; Hayes-Sterbenz, A. C. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Hilsabeck, T. J.; Wu, W. [General Atomics, PO Box 85608, San Diego, California 92186 (United States); Moy, K. [National Security Technologies, Special Technologies Laboratory, Santa Barbara, California 93111 (United States); Stoeffl, W. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

    2012-10-15

    The gamma-to-electron magnetic spectrometer, having better than 5% energy resolution, is proposed to resolve {gamma}-rays in the range of E{sub o}{+-} 20% in single shot, where E{sub o} is the central energy and is tunable from 2 to 25 MeV. Gamma-rays from inertial confinement fusion implosions interact with a thin Compton converter (e.g., beryllium) located at approximately 300 cm from the target chamber center (TCC). Scattered electrons out of the Compton converter enter an electromagnet placed outside the NIF chamber (approximately 600 cm from TCC) where energy selection takes place. The electromagnet provides tunable E{sub o} over a broad range in a compact manner. Energy resolved electrons are measured by an array of quartz Cherenkov converters coupled to photomultipliers. Given 100 detectable electrons in the energy bins of interest, 3 Multiplication-Sign 10{sup 14} minimum deuterium/tritium (DT) neutrons will be required to measure the 4.44 MeV {sup 12}C {gamma}-rays assuming 200 mg/cm{sup 2} plastic ablator areal density and 3 Multiplication-Sign 10{sup 15} minimum DT neutrons to measure the 16.75 MeV DT {gamma}-ray line.

  10. [Research of dual-photoelastic-modulator-based beat frequency modulation and Fourier-Bessel transform imaging spectrometer].

    Science.gov (United States)

    Wang, Zhi-Bin; Zhang, Rui; Wang, Yao-Li; Huang, Yan-Fei; Chen, You-Hua; Wang, Li-Fu; Yang, Qiang

    2014-02-01

    As the existing photoelastic-modulator(PEM) modulating frequency in the tens of kHz to hundreds of kHz between, leading to frequency of modulated interference signal is higher, so ordinary array detector cannot effectively caprure interference signal..A new beat frequency modulation method based on dual-photoelastic-modulator (Dual-PEM) and Fourier-Bessel transform is proposed as an key component of dual-photoelastic-modulator-based imaging spectrometer (Dual-PEM-IS) combined with charge coupled device (CCD). The dual-PEM are operated as an electro-optic circular retardance modulator, Operating the PEMs at slightly different resonant frequencies w1 and w2 respectively, generates a differential signal at a much lower heterodyne frequency that modulates the incident light. This method not only retains the advantages of the existing PEM, but also the frequency of modulated photocurrent decreased by 2-3 orders of magnitude (10-500 Hz) and can be detected by common array detector, and the incident light spectra can be obtained by Fourier-Bessel transform of low frequency component in the modulated signal. The method makes the PEM has the dual capability of imaging and spectral measurement. The basic principle is introduced, the basic equations is derived, and the feasibility is verified through the corresponding numerical simulation and experiment. This method has' potential applications in imaging spectrometer technology, and analysis of the effect of deviation of the optical path difference. This work provides the necessary theoretical basis for remote sensing of new Dual-PEM-IS and for engineering implementation of spectra inversion.

  11. Manual for the application of NURE 1974--1977 aerial gamma-ray spectrometer data

    International Nuclear Information System (INIS)

    Saunders, D.F.; Potts, M.J.

    1977-09-01

    This manual was prepared as an aid to those interested in the interpretation and application of high-sensitivity aerial gamma-ray spectrometer data in uranium exploration. Particular emphasis is on the first 10 radiometric surveys performed under the National Uranium Resource Evaluation (NURE) program. The primary purpose of aerial gamma-ray spectrometer surveys in the NURE program is to map regional distributions of near-surface natural radioelements, i.e., the uranium and thorium decay series, and potassium-40. These data along with an understanding of the geochemical behavior of the pertinent isotopes under a variety of conditions allow uranium-enriched areas of the earth's crust (uraniferous provinces) to be identified as part of the regional appraisal phase of prospecting. Uranium ore deposits tend to occur more frequently in these generally enriched regions than elsewhere, and, consequently, uraniferous provinces constitute preferred territory for follow-up exploration methods such as detailed aerial or surface radiometric prospecting, geological studies, etc., to define potential prospects. These in turn may be investigated by still more detailed surface geological studies perhaps supplemented by radon or uranium geochemical surveys and exploration drilling and logging. This manual outlines the fundamentals of uranium geology and geochemistry along with interpretive approaches which may be used to identify statistically and geochemically significant uranium anomalies and uraniferous provinces. Follow-up prospecting methods are summarized along with guides to recent literature. Specific suggestions are made as to interpretive approaches and applicable follow-up prospecting procedures tailored to fit the data characteristics and general environment of each of the first 10 NURE aerial gamma-ray spectrometer surveys performed by Geodata International, Inc. and Texas Instruments Incorporated

  12. Study of TGEs and Gamma-Flashes from thunderstorms in 20-3000 keV energy range with SINP MSU Gamma-Ray spectrometers

    International Nuclear Information System (INIS)

    Bogomolov, V.V.; Svertilov, S.I.; Maximov, I.A.; Panasyuk, M.I.; Garipov, G.K.

    2016-01-01

    SINP MSU provided a number of experiments with scintillator gamma-spectrometers for study of spectral, temporal and spatial characteristics of TGEs as well as for search of fast hard x-ray and gamma-ray flashes probably appearing at the moment of lightning. The measurements were done in Moscow region and in Armenia at Aragats Mountain. Each instrument used in this work was able to record data in so called “event mode”: the time of each interaction was recorded with ∼15 mcs accuracy together with detailed spectral data. Such design allowed one to look for fast sequences of gamma-quanta, coming at the moments of discharges during thunderstorms. The pulse-shape analysis made by detector electronics was used to separate real gammaray events and possible imitations of flashes by electrical disturbances when discharges occur. During the time period from spring to autumn of 2015 a number of TGEs were detected. Spectral analysis of received data showed that the energy spectrum of coming radiation in 20-3000 kev range demonstrate a set of gamma-ray lines that can be interpreted as radiation from Rn-222 daughter isotopes. The increase of Rn-222 radiation was detected during rainfalls with thunderstorm as well as during rainy weather without thunderstorms. Variations of Rn-222 radiation dominate in low energies (<2.6MeV) and must be taken into account in the experiments performed to measure low energy gamma-radiation from the electrons accelerated in thunderclouds. In order to determine the direction from which the additional gamma-quanta come the experiment with collimated gamma-spectrometer placed on rotated platform was done. The results of this experiment realized in Moscow region from august, 2015 will be presented as well as the results of comparison of different TGEs measured in Moscow region and in Armenia. (author)

  13. The gamma ray spectrometer GA.SP

    International Nuclear Information System (INIS)

    Bazzacco, D.

    1992-01-01

    GA.SP is a general purpose 4π detector array for advanced γ-spectroscopy and, in the same time, a suitable system for reaction mechanism studies. The detector is sited at the LNL Tandem+Linac accelerator and has been built as a joint project of INFN Padova, LNL, Milano and Firenze. The array consists of 40 Compton suppressed HPGe detectors and of a 4π calorimeter composed of 80 BGO crystals. The detector houses a reaction chamber of 34 cm diameter where a charged particles multiplicity filter composed of 40 Si detectors is going to be installed. Evaporation residues produced in the centre of GA.SP can be injected into the recoil mass spectrometer (RMS, named CAMEL) in use at LNL, without the need to remove any of the gamma detectors. The coupled operation of GA.SP, RMS and Si ball will give a unique instrument for identification and study of weak reaction channels. (author). 6 figs

  14. Establishing the fuel burn-up measuring system for 106 irradiated assemblies of Dalat reactor by using gamma spectrometer method

    International Nuclear Information System (INIS)

    Nguyen Minh Tuan; Pham Quang Huy; Tran Tri Vien; Trang Cao Su; Tran Quoc Duong; Dang Tran Thai Nguyen

    2013-01-01

    The fuel burn-up is an important parameter needed to be monitored and determined during a reactor operation and fuel management. The fuel burn-up can be calculated using computer codes and experimentally measured. This work presents the theory and experimental method applied to determine the burn-up of the irradiated and 36% enriched VVR-M2 fuel type assemblies of Dalat reactor. The method is based on measurement of Cs-137 absolute specific activity using gamma spectrometer. Designed measuring system consists of a collimator tube, high purity Germanium detector (HPGe) and associated electronics modules and online computer data acquisition system. The obtained results of measurement are comparable with theoretically calculated results. (author)

  15. The making of analog module for gamma camera interface

    International Nuclear Information System (INIS)

    Yulinarsari, Leli; Rl, Tjutju; Susila, Atang; Sukandar

    2003-01-01

    The making of an analog module for gamma camera has been conducted. For computerization of planar gamma camera 37 PMT it has been developed interface hardware technology and software between the planar gamma camera with PC. With this interface gamma camera image information (Originally analog signal) was changed to digital single, therefore processes of data acquisition, image quality increase and data analysis as well as data base processing can be conducted with the help of computers, there are three gamma camera main signals, i.e. X, Y and Z . This analog module makes digitation of analog signal X and Y from the gamma camera that conveys position information coming from the gamma camera crystal. Analog conversion to digital was conducted by 2 converters ADC 12 bit with conversion time 800 ns each, conversion procedure for each coordinate X and Y was synchronized using suitable strobe signal Z for information acceptance

  16. Development and Performance Characteristics of Personal Gamma Spectrometer for Radiation Monitoring Applications

    Directory of Open Access Journals (Sweden)

    Hye Min Park

    2016-06-01

    Full Text Available In this study, a personal gammaspectrometer was developed for use in applications in various fields, such as homeland security and environmental radiation monitoring systems. The prototype consisted of a 3 × 3 × 20 mm3 Ce-doped Gd–Al–Ga–garnet (Ce:GAGG crystal that was coupled to a Si photomultiplier (SiPM to measure γ radiation. The γ spectrometer could be accessed remotely via a mobile device. At room temperature, the implemented Ce:GAGG-SiPM spectrometer achieved energy resolutions of 13.5%, 6.9%, 5.8%, and 2.3% for 133Ba at 0.356 MeV, 22Na at 0.511 MeV, 137Cs at 0.662 MeV, and 60Co at 1.33 MeV, respectively. It consumed only about 2.7 W of power, had a mass of just 340 g (including the battery, and measured only 5.0 × 7.0 cm2.

  17. A carborne gamma-ray spectrometer system for natural radioactivity mapping and environmental monitoring

    International Nuclear Information System (INIS)

    Grasty, R.L.; Cox, J.R.

    1997-01-01

    This paper summarizes the experience gained in the use of a carborne gamma-ray spectrometer system for mapping both natural and man-made radiation. Particular emphasis is placed on the calibration of the system for converting the gamma-ray measurements to ground concentrations of potassium, uranium and thorium and the activity of 137 Cs. During the Finnish Emergency Response Exercise (Resume95), the carborne system was shown to be effective in mapping both natural and man-made radiation from 137 Cs fallout and in locating radioactive sources. The application of the carborne system for mineral exploration is also demonstrated. (au)

  18. Horizontal Ampoule Growth and Characterization of Mercuric Iodide at Controlled Gas Pressures for X-Ray and Gamma Ray Spectrometers

    International Nuclear Information System (INIS)

    Douglas, S.; McGregor Elsa; Ariesanti Bridget Corcoran

    2004-01-01

    The project developed a new method for producing high quality mercuric iodide crystals of x-ray and gamma spectrometers. Included are characterization of mercuric iodide crystal properties as a function of growth environment and fabrication and demonstration of room-temperature-operated high-resolution mercuric iodide spectrometers

  19. A Liquid-Cryogen-Free Cryostat for Ultrahigh Resolution Gamma-Ray Spectrometers

    International Nuclear Information System (INIS)

    Dreyer, J.G.; Hertrich, T.; Drury, O.B.; Hohne, J.; Friedrich, S.

    2008-01-01

    We are developing ultra-high energy resolution gamma-ray detectors based on superconducting transition edge sensors (TESs) for nuclear non-proliferation and fundamental science applications. They use bulk tin absorbers attached to molybdenum-copper multilayer TESs, and have achieved an energy resolution between 50 and 90 eV FWHM for gamma-ray energies below 122 keV. For increased user-friendliness, we have built a cryostat that attains the required detector operating temperature of 0.1 K at the push of a button without the use of cryogenic liquids. It uses a two-stage mechanical pulse tube refrigerator for precooling to ∼3 K, and a two-stage adiabatic demagnetization refrigerator for cooling to the base temperature. The cryostat is fully automated, attains a base temperature below 30 mK without the use of cryogenic liquids, and has a hold time of ∼2 days at 0.1 K between 1-hour demagnetization cycles. Here we discuss the performance of the cryostat for operation in a Gamma-spectrometer with 112-pixel arrays of superconducting TES detectors

  20. A carborne gamma-ray spectrometer system for natural radioactivity mapping and environmental monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Grasty, R.L.; Cox, J.R. [Exploranium Ltd., Mississauga, Ontario (Canada)

    1997-12-31

    This paper summarizes the experience gained in the use of a carborne gamma-ray spectrometer system for mapping both natural and man-made radiation. Particular emphasis is placed on the calibration of the system for converting the gamma-ray measurements to ground concentrations of potassium, uranium and thorium and the activity of {sup 137}Cs. During the Finnish Emergency Response Exercise (Resume95), the carborne system was shown to be effective in mapping both natural and man-made radiation from {sup 137}Cs fallout and in locating radioactive sources. The application of the carborne system for mineral exploration is also demonstrated. (au). 10 refs.

  1. A carborne gamma-ray spectrometer system for natural radioactivity mapping and environmental monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Grasty, R L; Cox, J R [Exploranium Ltd., Mississauga, Ontario (Canada)

    1998-12-31

    This paper summarizes the experience gained in the use of a carborne gamma-ray spectrometer system for mapping both natural and man-made radiation. Particular emphasis is placed on the calibration of the system for converting the gamma-ray measurements to ground concentrations of potassium, uranium and thorium and the activity of {sup 137}Cs. During the Finnish Emergency Response Exercise (Resume95), the carborne system was shown to be effective in mapping both natural and man-made radiation from {sup 137}Cs fallout and in locating radioactive sources. The application of the carborne system for mineral exploration is also demonstrated. (au). 10 refs.

  2. A mobile gamma ray spectrometer system for nuclear hazard mapping

    CERN Document Server

    Smethurst, M A

    2000-01-01

    The Geological Survey of Norway has developed a system for mobile gamma ray spectrometer surveying suitable for use in nuclear emergencies where potentially dangerous radioactive materials have been released into the environment. The measuring system has been designed for use with different kinds of transportation platforms. These include fixed-wing aircraft, helicopters and vans. The choice of transportation platform depends on the nature of the nuclear emergency. Widespread fallout from a distant source can be mapped quickly from the air while local sources of radiation can be delineated by a car-borne system. The measuring system processes gamma ray spectra in real time. The operator of the system is therefore able to guide surveying in accordance with meaningful data values and immediately report these values to decision making The operator is presented with a number of different displays suited to different kinds of nuclear emergencies that lead to more efficient surveying. Real time processing of data m...

  3. Time series data correction for the Chang'E-1 gamma-ray spectrometer

    Institute of Scientific and Technical Information of China (English)

    Li-Yan Zhang; Yong-Liao Zou; Jian-Zhong Liu; Jian-Jun Liu; Ji Shen; Ling-Li Mu; Xin Ren; Wei-Bin Wen; Chun-Lai Li

    2011-01-01

    The main goal of the gamma-ray spectrometer (GRS) onboard Chang'E-l (CE-1) is to acquire global maps of elemental abundances and their distributions on the moon, since such maps will significantly improve our understanding of lunar formation and evolution. To derive the elemental maps and enable research on lunar formation and evolution, raw data that are received directly from the spacecraft must be converted into time series corrected gamma-ray spectra. The data correction procedures for the CE-1 GRS time series data are thoroughly described. The processing procedures to create the time series gamma-ray spectra described here include channel processing, optimal data selection, energy calibration, gain correction, dead time correction, geometric correction, orbit altitude normalization, eliminating unusable data and galactic cosmic ray correction. Finally, descriptions are also given on data measurement uncertainties, which will help the interested scientists to understand and estimate various uncertainties associated with the above data processing.

  4. Time series data correction for the Chang'E-1 gamma-ray spectrometer

    International Nuclear Information System (INIS)

    Zhang Liyan; Zou Yongliao; Liu Jianzhong; Liu Jianjun; Shen Ji; Mu Lingli; Ren Xin; Wen Weibin; Li Chunlai

    2011-01-01

    The main goal of the gamma-ray spectrometer (GRS) onboard Chang'E-1 (CE-1) is to acquire global maps of elemental abundances and their distributions on the moon, since such maps will significantly improve our understanding of lunar formation and evolution. To derive the elemental maps and enable research on lunar formation and evolution, raw data that are received directly from the spacecraft must be converted into time series corrected gamma-ray spectra. The data correction procedures for the CE-1 GRS time series data are thoroughly described. The processing procedures to create the time series gamma-ray spectra described here include channel processing, optimal data selection, energy calibration, gain correction, dead time correction, geometric correction, orbit altitude normalization, eliminating unusable data and galactic cosmic ray correction. Finally, descriptions are also given on data measurement uncertainties, which will help the interested scientists to understand and estimate various uncertainties associated with the above data processing. (research papers)

  5. Gamma-ray spectrometer system with high efficiency and high resolution

    International Nuclear Information System (INIS)

    Moss, C.E.; Bernard, W.; Dowdy, E.J.; Garcia, C.; Lucas, M.C.; Pratt, J.C.

    1983-01-01

    Our gamma-ray spectrometer system, designed for field use, offers high efficiency and high resolution for safeguards applications. The system consists of three 40% high-purity germanium detectors and a LeCroy 3500 data acquisition system that calculates a composite spectrum for the three detectors. The LeCroy 3500 mainframe can be operated remotely from the detector array with control exercised through modems and the telephone system. System performance with a mixed source of 125 Sb, 154 Eu, and 155 Eu confirms the expected efficiency of 120% with the overall resolution showing little degradation over that of the worst detector

  6. Spectrum-to-dose conversion operator value function of a Ge(Li) in-situ environmental gamma-ray spectrometer

    International Nuclear Information System (INIS)

    Terada, Hiromi; Sakai, Eiji; Katagiri, Masaki

    1976-05-01

    A spectrum-to-dose conversion operator value function was obtained for a 73cm 3 closed-end coaxial Ge(Li) in-situ environmental gamma-ray spectrometer; factors influencing the function are considered. (auth.)

  7. USE OF PORTABLE GAMMA SPECTROMETERS FOR IDENTIFYING PERSONS EXPOSED IN A NUCLEAR CRITICALITY

    Energy Technology Data Exchange (ETDEWEB)

    Veinot, K. G. [Y-12 National Security Complex; Gose, B. T. [Y-12 National Security Complex; Bogard, James S [ORNL

    2009-01-01

    At Y-12 triage-style assessments are used to identify persons potentially exposed to high doses from criticality accident radiations using portable instruments by assessing the presence of activated sodium atoms in a person's blood. Historically, simple hand-held Geiger-Mueller (G-M) probes were used for these purposes although it was recognized that, since these instruments contain no information on incident photon energy, it was impossible to differentiate between photons emitted by contamination on the potentially exposed worker from activation of sodium in the person s blood. This works examines the use of a portable gamma spectrometer for assessing blood sodium activation. Irradiations of a representative phantom were performed using two neutron source configurations (unmoderated and polyethylene-moderated 252Cf) and measurements were made using the spectrometer and a G-M detector following irradiation. Detection limits in terms of personnel neutron dose are given for two neutron fields representing metaland solution criticality spectra. Both Geiger-Mueller and spectrometer results indicate a low minimum detectable neutron dose indicating that both instrument are useful as an emergency response instrument. The spectrometer has the added benefit of discriminating between surface contamination and blood sodium activation.

  8. USE OF PORTABLE GAMMA SPECTROMETERS FOR IDENTIFYING PERSONS EXPOSED IN A NUCLEAR CRITICALITY

    International Nuclear Information System (INIS)

    Veinot, K.G.; Gose, B.T.; Bogard, James S.

    2009-01-01

    At Y-12 triage-style assessments are used to identify persons potentially exposed to high doses from criticality accident radiations using portable instruments by assessing the presence of activated sodium atoms in a person's blood. Historically, simple hand-held Geiger-Mueller (G-M) probes were used for these purposes although it was recognized that, since these instruments contain no information on incident photon energy, it was impossible to differentiate between photons emitted by contamination on the potentially exposed worker from activation of sodium in the persons blood. This works examines the use of a portable gamma spectrometer for assessing blood sodium activation. Irradiations of a representative phantom were performed using two neutron source configurations (unmoderated and polyethylene-moderated 252Cf) and measurements were made using the spectrometer and a G-M detector following irradiation. Detection limits in terms of personnel neutron dose are given for two neutron fields representing metal and solution criticality spectra. Both Geiger-Mueller and spectrometer results indicate a low minimum detectable neutron dose indicating that both instrument are useful as an emergency response instrument. The spectrometer has the added benefit of discriminating between surface contamination and blood sodium activation.

  9. A comparative study of LaBr3(Ce(3+)) and CeBr3 based gamma-ray spectrometers for planetary remote sensing applications.

    Science.gov (United States)

    Kozyrev, A; Mitrofanov, I; Owens, A; Quarati, F; Benkhoff, J; Bakhtin, B; Fedosov, F; Golovin, D; Litvak, M; Malakhov, A; Mokrousov, M; Nuzhdin, I; Sanin, A; Tretyakov, V; Vostrukhin, A; Timoshenko, G; Shvetsov, V; Granja, C; Slavicek, T; Pospisil, S

    2016-08-01

    The recent availability of large volume cerium bromide crystals raises the possibility of substantially improving gamma-ray spectrometer limiting flux sensitivities over current systems based on the lanthanum tri-halides, e.g., lanthanum bromide and lanthanum chloride, especially for remote sensing, low-level counting applications or any type of measurement characterized by poor signal to noise ratios. The Russian Space Research Institute has developed and manufactured a highly sensitive gamma-ray spectrometer for remote sensing observations of the planet Mercury from the Mercury Polar Orbiter (MPO), which forms part of ESA's BepiColombo mission. The Flight Model (FM) gamma-ray spectrometer is based on a 3-in. single crystal of LaBr3(Ce(3+)) produced in a separate crystal development programme specifically for this mission. During the spectrometers development, manufacturing, and qualification phases, large crystals of CeBr3 became available in a subsequent phase of the same crystal development programme. Consequently, the Flight Spare Model (FSM) gamma-ray spectrometer was retrofitted with a 3-in. CeBr3 crystal and qualified for space. Except for the crystals, the two systems are essentially identical. In this paper, we report on a comparative assessment of the two systems, in terms of their respective spectral properties, as well as their suitability for use in planetary mission with respect to radiation tolerance and their propensity for activation. We also contrast their performance with a Ge detector representative of that flown on MESSENGER and show that: (a) both LaBr3(Ce(3+)) and CeBr3 provide superior detection systems over HPGe in the context of minimally resourced spacecraft and (b) CeBr3 is a more attractive system than LaBr3(Ce(3+)) in terms of sensitivities at lower gamma fluxes. Based on the tests, the FM has now been replaced by the FSM on the BepiColombo spacecraft. Thus, CeBr3 now forms the central gamma-ray detection element on the MPO spacecraft.

  10. Orbital Normalization of MESSENGER Gamma-Ray Spectrometer Data

    Science.gov (United States)

    Rhodes, E. A.; Peplowski, P. N.; Evans, L. G.; Hamara, D. K.; Boynton, W. V.; Solomon, S. C.

    2011-12-01

    The MESSENGER Gamma-Ray Spectrometer (GRS) measures energy spectra of gamma rays emanating from the surface of Mercury. Analysis of these spectra provides elemental abundances of surface material. The MESSENGER mission necessarily provides some data normalization challenges for GRS analysis. So as to keep the spacecraft cool while orbiting the dayside of the planet, the orbits are highly eccentric, with altitudes varying from 200-500 km to ~ 15,000 km. A small fraction of time is spent at the low altitudes where gamma-ray signals are largest, requiring a large number of orbits to yield sufficient counting statistics for elemental analysis. Also, the sunshade must always shield the spacecraft from the Sun, which causes the orientation of the GRS often to be far from nadir-pointing, so the detector efficiency and attenuation of gamma rays from the planet must be known for a wide range of off-nadir orientations. An efficiency/attenuation map for the expected ranges of orientations and energies was constructed in a ground calibration experiment for a limited range of orientations using a nuclear reactor and radioisotope sources, and those results were extended to other orientations by radiation transport computations using as input a computer-aided design model of the spacecraft and its composition. This normalization has allowed abundance determinations of elements K, Th, and U from radioisotopes of these elements in the Mercury regolith during the first quarter of the year-long mission. These results provide constraints on models of Mercury's chemical and thermal evolution. The normalization of gamma-ray spectra for surface elements not having radioisotopes is considerably more complex; these gamma rays come from neutron inelastic-scatter and capture reactions in the regolith, where the neutrons are generated by cosmic ray impact onto the planet. A radiation transport computation was performed to generate the expected count rates in the neutron-generated gamma

  11. Replacement of a photomultiplier tube in a 2-inch thallium-doped sodium iodide gamma spectrometer with silicon photomultipliers and a light guide

    Directory of Open Access Journals (Sweden)

    Chankyu Kim

    2015-06-01

    Full Text Available The thallium-doped sodium iodide [NaI(Tl] scintillation detector is preferred as a gamma spectrometer in many fields because of its general advantages. A silicon photomultiplier (SiPM has recently been developed and its application area has been expanded as an alternative to photomultiplier tubes (PMTs. It has merits such as a low operating voltage, compact size, cheap production cost, and magnetic resonance compatibility. In this study, an array of SiPMs is used to develop an NaI(Tl gamma spectrometer. To maintain detection efficiency, a commercial NaI(Tl 2′ × 2′ scintillator is used, and a light guide is used for the transport and collection of generated photons from the scintillator to the SiPMs without loss. The test light guides were fabricated with polymethyl methacrylate and reflective materials. The gamma spectrometer systems were set up and included light guides. Through a series of measurements, the characteristics of the light guides and the proposed gamma spectrometer were evaluated. Simulation of the light collection was accomplished using the DETECT 97 code (A. Levin, E. Hoskinson, and C. Moison, University of Michigan, USA to analyze the measurement results. The system, which included SiPMs and the light guide, achieved 14.11% full width at half maximum energy resolution at 662 keV.

  12. Conditioning the gamma spectrometer for activity measurement at very high background

    OpenAIRE

    Yan, Weihua; Zhang, Liguo; Zhang, Zhao; Xiao, Zhigang

    2013-01-01

    The application of a high purity germanium (HPGe) gamma spectrometer in determining the fuel element burnup in a future reactor is studied. The HPGe detector is exposed by a Co60 source with varying irradiation rate from 10 kcps to 150 kcps to simulate the input counting rate in real reactor environment. A Cs137 and a Eu152 source are positioned at given distances to generate certain event rate in the detector with the former being proposed as a labeling nuclide to measure the burnup of fuel ...

  13. Crystal-diffraction spectrometer of increased efficiency

    International Nuclear Information System (INIS)

    Saukov, A.I.; Gornitsyn, G.A.; Morozov, N.A.

    1985-01-01

    The geometry of the spectrometer is illustrated in this paper. An attempt is made to achieve optimal design of the spectrometer by finding the coefficient of reflection of the gamma radiation from the various Ge planes. In these experiments, the Du Mond design was used in the spectrometer. Illustrations are provided to explain dependence of the relative efficiency upon the energy of the gamma quanta

  14. Detection of an intense polychromatic gamma beam modulated at 3000 MHz; Detection d'un faisceau intense de gammas polychromatiques module a 3000 MHz

    Energy Technology Data Exchange (ETDEWEB)

    Beil, H; Veyssiere, A; Daujat, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1968-07-01

    This paper presents two methods of detection of a {gamma} beam modulated at very high frequencies. The intense modulated beam is created by means of Bremsstrahlung in a gold-target, the latter having been placed in the emerging electron beam of the Linac at Saclay. A tentative interpretation of the physical phenomena involved in the detection processes is also given. The empirical data agree reasonably well with numerical evaluations based on well established theoretical concepts concerning these phenomena. (authors) [French] Cet article presente deux facons de detecter un faisceau de {gamma} module a haute frequence. Le faisceau intense de {gamma} est cree par l'impact d'electrons (acceleres dans un accelerateur lineaire) sur une cible en or. Une tentative d'interpretation des phenomenes physiques mis en cause dans le processus de detection est donnee et les valeurs experimentales trouvees s'accordent raisonnablement bien avec les valeurs calculees a partir des considerations theoriques des phenomenes. (auteurs)

  15. Analysis of the Interference Modulation Depth in the Fourier Transform Spectrometer

    Directory of Open Access Journals (Sweden)

    Rilong Liu

    2015-01-01

    Full Text Available Based on the principle of the Michelson interferometer, the paper briefly describes the theoretical significance and calculates and deduces three expressions of the interference modulation depth. The influence of the surface shape error of plane mirror on modulation depth is analyzed, and the tolerance of error is also pointed out. Moreover, the dependence of modulation depth on the reflectance change of beam splitter interface is also analyzed, and the curve is given. It is concluded that this paper is of general significance for the Fourier transform spectrometer based on the principle of the Michelson two-beam interference.

  16. High performance gamma-ray spectrometer for runaway electron studies on the FT-2 tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Shevelev, A.E., E-mail: Shevelev@cycla.ioffe.ru [Ioffe Institute, Politekhnicheskaya 26, St. Petersburg 194021 (Russian Federation); Khilkevitch, E.M.; Lashkul, S.I.; Rozhdestvensky, V.V.; Altukhov, A.B.; Chugunov, I.N.; Doinikov, D.N.; Esipov, L.A.; Gin, D.B.; Iliasova, M.V.; Naidenov, V.O.; Nersesyan, N.S.; Polunovsky, I.A.; Sidorov, A.V. [Ioffe Institute, Politekhnicheskaya 26, St. Petersburg 194021 (Russian Federation); Kiptily, V.G. [CCFE, Culham Science Centre, Abingdon, Oxon X14 3DB (United Kingdom)

    2016-09-11

    A gamma-ray spectrometer based on LaBr{sub 3}(Ce) scintillator has been used for measurements of hard X-ray emission generated by runaway electrons in the FT-2 tokamak plasmas. Using of the fast LaBr{sub 3}(Ce) has allowed extending count rate range of the spectrometer by a factor of 10. A developed digital processing algorithm of the detector signal recorded with a digitizer sampling rate of 250 MHz has provided a pulse height analysis at count rates up to 10{sup 7} s{sup −1}. A spectrum deconvolution code DeGaSum has been applied for inferring the energy distribution of runaway electrons escaping from the plasma and interacting with materials of the FT-2 limiter in the vacuum chamber. The developed digital signal processing technique for LaBr{sub 3}(Ce) spectrometer has allowed studying the evolution of runaways energy distribution in the FT-2 plasma discharges with time resolution of 1–5 ms.

  17. A microprocessor-based gamma-ray spectrometer with gain stabilized single-channel analyzers

    International Nuclear Information System (INIS)

    Borg, P.J.; Huppert, P.; Phillips, P.L.; Waddington, P.J.

    1985-01-01

    The design and performance of a self-contained microprocessor-based gamma-ray spectrometer for use in geophysical measurements using nuclear techniques is described. The instrument uses single-channel analyzers which are inherently simpler and faster than the Wilkinson or successive approximation ADC. A novel technique of gain stabilization together with a simple means of energy calibration has been developed. The modular design of the equipment makes it suitable for multidetector usage, required in a number of nucleonic gauges for the quantitative measurement of chemical constituents. (orig.)

  18. Frequency of gamma oscillations in humans is modulated by velocity of visual motion

    Science.gov (United States)

    Butorina, Anna V.; Sysoeva, Olga V.; Prokofyev, Andrey O.; Nikolaeva, Anastasia Yu.; Stroganova, Tatiana A.

    2015-01-01

    Gamma oscillations are generated in networks of inhibitory fast-spiking (FS) parvalbumin-positive (PV) interneurons and pyramidal cells. In animals, gamma frequency is modulated by the velocity of visual motion; the effect of velocity has not been evaluated in humans. In this work, we have studied velocity-related modulations of gamma frequency in children using MEG/EEG. We also investigated whether such modulations predict the prominence of the “spatial suppression” effect (Tadin D, Lappin JS, Gilroy LA, Blake R. Nature 424: 312-315, 2003) that is thought to depend on cortical center-surround inhibitory mechanisms. MEG/EEG was recorded in 27 normal boys aged 8–15 yr while they watched high-contrast black-and-white annular gratings drifting with velocities of 1.2, 3.6, and 6.0°/s and performed a simple detection task. The spatial suppression effect was assessed in a separate psychophysical experiment. MEG gamma oscillation frequency increased while power decreased with increasing velocity of visual motion. In EEG, the effects were less reliable. The frequencies of the velocity-specific gamma peaks were 64.9, 74.8, and 87.1 Hz for the slow, medium, and fast motions, respectively. The frequency of the gamma response elicited during slow and medium velocity of visual motion decreased with subject age, whereas the range of gamma frequency modulation by velocity increased with age. The frequency modulation range predicted spatial suppression even after controlling for the effect of age. We suggest that the modulation of the MEG gamma frequency by velocity of visual motion reflects excitability of cortical inhibitory circuits and can be used to investigate their normal and pathological development in the human brain. PMID:25925324

  19. Measuring GAMMA 10 end-loss ions with an ELIS [end-loss-ion spectrometers] from TMX-U

    International Nuclear Information System (INIS)

    Foote, J.H.

    1987-01-01

    The author spent the period from March 22 to July 10, 1987, at the GAMMA 10 tandem-mirror experiment at the University of Tsukuba in Tsukuba, Japan. The purpose of this extended trip was to install on GAMMA 10 one of the end-loss-ion spectrometers (ELIS) used on TMX-U (Tandem Mirror Experiment-Upgrade) at LLNL and to make plasma measurements there with this diagnostic instrument. This report discusses the considerable planning and preparations that preceded the trip, the actual experience with the ELIS equipment at GAMMA 10, data and results obtained while the author was there, GAMMA 10 experimental procedures, the scientific and technical support during the stay, and some final comments and suggestions concerning an international exchange such as this one. The data acquired on GAMMA 10 while there, along with earlier data, present an encouraging picture of a plasma in a thermal-barrier mode in a tandem-mirror, magnetic-fusion machine. 6 refs

  20. Field and frequency modulated sub-THz electron spin resonance spectrometer

    Directory of Open Access Journals (Sweden)

    Christian Caspers

    2016-05-01

    Full Text Available 260-GHz radiation is used for a quasi-optical electron spin resonance (ESR spectrometer which features both field and frequency modulation. Free space propagation is used to implement Martin-Puplett interferometry with quasi-optical isolation, mirror beam focusing, and electronic polarization control. Computer-aided design and polarization pathway simulation lead to the design of a compact interferometer, featuring lateral dimensions less than a foot and high mechanical stability, with all components rated for power levels of several Watts suitable for gyrotron radiation. Benchmark results were obtained with ESR standards (BDPA, DPPH using field modulation. Original high-field ESR of 4f electrons in Sm3+-doped Ceria was detected using frequency modulation. Distinct combinations of field and modulation frequency reach a signal-to-noise ratio of 35 dB in spectra of BDPA, corresponding to a detection limit of about 1014 spins.

  1. A comparative study of LaBr{sub 3}(Ce{sup 3+}) and CeBr{sub 3} based gamma-ray spectrometers for planetary remote sensing applications

    Energy Technology Data Exchange (ETDEWEB)

    Kozyrev, A., E-mail: kozyrev@mx.iki.rssi.ru; Mitrofanov, I.; Bakhtin, B.; Fedosov, F.; Golovin, D.; Litvak, M.; Malakhov, A.; Mokrousov, M.; Nuzhdin, I.; Sanin, A.; Tretyakov, V.; Vostrukhin, A. [Space Research Institute of the Russian Academy of Sciences (IKI), 84/32 Profsoyuznaya St., Moscow 117997 (Russian Federation); Owens, A.; Benkhoff, J. [European Space Agency, ESTEC, Keplerlaan, 2200 AG Noordwijk (Netherlands); Quarati, F. [AP, RST, FAME, Delft University of Technology, Mekelweg 15, 2629 JB Delft (Netherlands); Gonitec BV, J. Bildersstraat 60, 2596 EJ Den Haag (Netherlands); Timoshenko, G.; Shvetsov, V. [Joint Institute for Nuclear Research, Joliot-Curie 6, Dubna, Moscow Region 141980 (Russian Federation); Granja, C.; Slavicek, T.; Pospisil, S. [Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, 12800 Prague 2 (Czech Republic)

    2016-08-15

    The recent availability of large volume cerium bromide crystals raises the possibility of substantially improving gamma-ray spectrometer limiting flux sensitivities over current systems based on the lanthanum tri-halides, e.g., lanthanum bromide and lanthanum chloride, especially for remote sensing, low-level counting applications or any type of measurement characterized by poor signal to noise ratios. The Russian Space Research Institute has developed and manufactured a highly sensitive gamma-ray spectrometer for remote sensing observations of the planet Mercury from the Mercury Polar Orbiter (MPO), which forms part of ESA’s BepiColombo mission. The Flight Model (FM) gamma-ray spectrometer is based on a 3-in. single crystal of LaBr{sub 3}(Ce{sup 3+}) produced in a separate crystal development programme specifically for this mission. During the spectrometers development, manufacturing, and qualification phases, large crystals of CeBr{sub 3} became available in a subsequent phase of the same crystal development programme. Consequently, the Flight Spare Model (FSM) gamma-ray spectrometer was retrofitted with a 3-in. CeBr{sub 3} crystal and qualified for space. Except for the crystals, the two systems are essentially identical. In this paper, we report on a comparative assessment of the two systems, in terms of their respective spectral properties, as well as their suitability for use in planetary mission with respect to radiation tolerance and their propensity for activation. We also contrast their performance with a Ge detector representative of that flown on MESSENGER and show that: (a) both LaBr{sub 3}(Ce{sup 3+}) and CeBr{sub 3} provide superior detection systems over HPGe in the context of minimally resourced spacecraft and (b) CeBr{sub 3} is a more attractive system than LaBr{sub 3}(Ce{sup 3+}) in terms of sensitivities at lower gamma fluxes. Based on the tests, the FM has now been replaced by the FSM on the BepiColombo spacecraft. Thus, CeBr{sub 3} now forms

  2. Characterization of the InSTEC's low-background gamma spectrometer for environmental radioactivity studies

    International Nuclear Information System (INIS)

    Diaz Rizo, O.; Lopez Pino, N.; D'Alessandro Rodriguez, K.; Reyes, H.; Padilla Cabal, F.; Arado Lopez, J.O.; Casanova Diaz, A.O.; Gelen Rudnikas, A.; Rodenas Palomino, C.; Gomez Arozamena, J.

    2010-01-01

    The capabilities of the Low-Background Gamma Spectrometer (LBGS) at InSTEC were studied for environmental purposes. Fifty three γ-lines were identified in the LBGS background spectrum. The Minimum Detectable Activity for 2 10 Pb, 2 38 U, 2 26 Ra, 1 37 Cs, 2 32 Th and 4 0K were calculated using the detector's volumetric efficiency simulated by the Monte Carlo method. Validation was performed by absolute and relative analysis of radionuclide activities present in a marine sediment certified material. (author)

  3. Airborne gamma-ray spectrometer and magnetometer survey, Meade River Quadrangle, Alaska. Final report

    International Nuclear Information System (INIS)

    1981-02-01

    The results obtained from an airborne high sensitivity gamma-ray spectrometer and magnetometer survey over the Meade River map area of Alaska are presented. Based on the criteria outlined in the general section on interpretation, a total of eight uranium anomalies have been outlined on the interpretation map. Most of these are only weakly to moderately anomalous. Zones 3 and 7 are relatively better than the others though none of the anomalies are thought to be of any economic significance. No follow-up work is recommended

  4. Airborne gamma-ray spectrometer and magnetometer survey: north/south tieline. Final report

    International Nuclear Information System (INIS)

    1981-05-01

    An airborne high sensitivity gamma-ray spectrometer and magnetometer survey was conducted along the 99 0 longitude meridian from the Canadian border southward to the Mexican border. A total of 1555 line miles of geophysical data were acquired and, subsequently, compiled. The north-south tieline was flown as part of the National Uranium Resources Evaluation. NURE is a program of the US Department of Energy's Grand Junction, Colorado, office to acquire and compile geologic and other information with which to assess the magnitude and distribution of uranium resources and to determine areas favorable for the occurrence of uranium in the United States

  5. Software for mass spectrometer control

    International Nuclear Information System (INIS)

    Curuia, Marian; Culcer, Mihai; Anghel, Mihai; Iliescu, Mariana; Trancota, Dan; Kaucsar, Martin; Oprea, Cristiana

    2004-01-01

    The paper describes a software application for the MAT 250 mass spectrometer control, which was refurbished. The spectrometer was bring-up-to-date using a hardware structure on its support where the software application for mass spectrometer control was developed . The software application is composed of dedicated modules that perform given operations. The instructions that these modules have to perform are generated by a principal module. This module makes possible the change of information between the modules that compose the software application. The use of a modal structure is useful for adding new functions in the future. The developed application in our institute made possible the transformation of the mass spectrometer MAT 250 into a device endowed with other new generation tools. (authors)

  6. Development and Building of Radioactive Concrete Pads for calibration of the airborne and ground gamma-ray spectrometers, used in mineral exploration and hydrocarbons

    International Nuclear Information System (INIS)

    Carlos, Dionisio Uendro

    2006-01-01

    Eight transportable calibration pads were built in to be used as concentration standards for portable and airborne gamma-ray spectrometers calibrations. The pads construction procedure is described in full detail. The pads, with dimensions of 1 m x 1 m x 0,30 m and masses between 593 kg and 673 kg were made radioactive by the addition of different amounts of k-feldspar, caldasite and monazitic sand to the concrete masses. The potassium, uranium and thorium concentration vary significantly in the pads, reaching maximum values of 5,7% of K, 45,6 ppm eU and 137 ppm eTh. The distribution of the gamma radiation flux from the pads surfaces and the heterogeneity magnitudes of the radioactive elements concentration were experimentally established. An example of gamma-ray spectrometer calibration is presented. (author)

  7. Airborne gamma-ray spectrometer and magnetometer survey, Sagavanirktok Quadrangle, Alaska. Volume I. Final report

    International Nuclear Information System (INIS)

    1981-03-01

    The results obtained from an airborne high sensitivity gamma-ray spectrometer and magnetometer survey over the Sagavanirktok map area of Alaska are presented. Based on the criteria outlined in the general section on interpretation, a total of eight uranium anomalies have been outlined on the interpretation map. However, all of these zones are only weakly to moderately anomalous. None are thought to be indicative of local enrichment of uranium to economically significant levels. No follow-up work is recommended

  8. An electrostatic RF modulator for Moessbauer gamma-rays

    International Nuclear Information System (INIS)

    Ognjanov, N.I.; Tsankov, L.T.; Ivanov, P.V.

    1983-01-01

    A new device is proposed for rf acoustic modulation of Moessbauer gamma-radiation, based on the principle of the electrostatic speaker. Certain features of the construction are discussed and results from tests are presented. (orig.)

  9. Silicon spectrometer with a Peltier refrigerator

    International Nuclear Information System (INIS)

    Belcarz, E.; Chwaszczewska, J.; Hahn, G.; Nowicki, W.; Sawicka, B.; Skoczek, K.; Slapa, M.; Szymczak, M.

    1974-01-01

    This paper describes a spectrometer with a Si(Li) detector cooled by a Peltier refrigerator. The spectrometer is able to analyse samples of practically all most frequently encountered emitters of alpha, beta and low energy gamma radiation. The energy resolution were about 1.3-1.5 keV for 14 keV gamma radiation. The system can also operate in field conditions in the fluorescence analysis. (author)

  10. Characterization of the InSTEC's low-background gamma spectrometer for environmental radioactivity studies

    International Nuclear Information System (INIS)

    Diaz Rizo, O.; Lopez Pino, N.; D'Alessandro Rodriguez, K.; Reyes, H.; Padilla Cabal, F.; Arado Lopez, J.O.; Casanova Diaz, A.O.; Gelen Rudnikas, A.; Rodenas Palomino, C.; Gomez Arozamena, J.

    2009-01-01

    The capabilities of the Low-Background Gamma Spectrometer (LBGS) at InSTEC were studied for environmental purposes. Fifty three ?-lines were fixed/identified? in the LBGS background spectrum. The Minimum Detectable Activity for 2 10 Pb, 2 38 U, 2 26 Ra, 1 37 Cs, 2 32 Th and 4 0K were calculated using the detector's volumetric efficiency simulated by the Monte Carlo method. The radionuclide activities in a marine sediment standard reference material? were determined by absolute and relative methods for validation./¿absolute and relative validation? (author)

  11. A 64 Mbyte VME histogramming memory card for the GA.SP gamma spectrometer

    International Nuclear Information System (INIS)

    Cavedini, Z.; DePoli, M.; Maron, G.; Vedovato, G.

    1990-01-01

    This paper reports on a 64 Mbyte VME histogramming memory card designed and built to cover the on-line and off-line data analysis needs of the GA.SP spectrometer (a 40 HpGe gamma detector array in development at LNL). The card combines the standard features of the VME/VSB bus with some special built-in functions: single cycle fast histogramming operations (typical channel increment time of 550 ns including the bus arbitration), fast clear of the whole memory (∼1 second to erase 64 Mbyte) and data broadcasting

  12. Cosmic gamma ray detection and discovery potential with the AMS-2 spectrometer; Detection de rayons {gamma} cosmiques et potentiel de decouvertes avec le spectrometre AMS-02

    Energy Technology Data Exchange (ETDEWEB)

    Girard, L

    2004-12-15

    Yet designed to measure charged component of the cosmic rays, the foreseen Alpha Magnetic Spectrometer (AMS-02) could also release {gamma}-ray studies, in the energy range from GeV to TeV, using the tracker system, for {gamma}-rays converted in e{sup +}e{sup -} pair, and the electromagnetic calorimeter. In the first part of the thesis are described the calibrations and the performances of the engineering model of the calorimeter, obtained from the analysis of data taken during a test-beam performed at CERN in July 2002. In the second part of the thesis, the AMS-02 discovery potential for {gamma}-astrophysics is presented. While exposure maps of the {gamma}--sky are computed for one year of data taking with the {gamma}--detectors, the acceptance of the calorimeter is obtained from Monte-Carlo simulations. The AMS-02 potential is then estimated for signals from the Vela pulsar and for some supersymmetric signals from the Galactic Center. (author)

  13. Ready to use detector modules for the NEAT spectrometer: Concept, design, first results

    Science.gov (United States)

    Magi, Ádám; Harmat, Péter; Russina, Margarita; Günther, Gerrit; Mezei, Ferenc

    2018-05-01

    The paper presents the detector system developed by Datalist Systems, Ltd. (previously ANTE Innovative Technologies) for the NEAT-II spectrometer at HZB. We present initial concept, design and implementation highlights as well as the first results of measurements such as position resolution. The initial concept called for modular architecture with 416 3He detector tubes organized into thirteen 32-tube modules that can be independently installed and removed to and from the detector vacuum chamber for ease of maintenance. The unalloyed aluminum mechanical support modules for four 8-tube units each also house the air-boxes that contain the front-end electronics (preamplifiers) that need to be on atmospheric pressure. The modules have been manufactured and partly assembled in Hungary and then fully assembled and installed on site by Datalist Systems crew. The signal processing and data acquisition solution is based on low time constant (˜60 ns) preamplifier electronics and sampling ADC's running at 50 MS/s (i.e. a sample every 20 ns) for all 832 data channels. The preamplifiers are proprietary, developed specifically for the NEAT spectrometer, while the ADC's and the FPGA's that further process the data are based on National Instruments products. The data acquisition system comprises 26 FPGA modules each serving 16 tubes (providing for up to 50 kHz count rate per individual tube) and it is organized into two PXI chassis and two data acquisition computers that perform post-processing, event classification and provide appropriate preview of the collected data. The data acquisition software based on Event Recording principles provides a single point of contact for the scientific software with an Event Record List with absolute timestamps of 100ns resolution, timing data of 100 ns resolution for the seven discs chopper system as well as classification data that can be used for flexible data filtering in off-line analysis of the gathered data. A unique 3-tier system of

  14. Distributed control and data acquisition for the EUROGAM gamma ray spectrometer

    International Nuclear Information System (INIS)

    Owen, E.C.G.

    1992-01-01

    EUROGAM is an Anglo/French Gamma Ray Detector which will alternate between the Tandem Van der Graaf at Daresbury and the Vivitron at Strasbourg. Because of the need to conform to the standards of Laboratories in two different countries, and the very sensitive nature of electronics for Germanium Gamma Ray telescopes, the newly emerging VXlbus (VMEbus EXtensions for Instrumentation) was chosen as the basis for control and data acquisition. This entailed a major programme of development for both the signal processing front end modules for Germanium and Bismuth Germanate detectors, and also for the hardware and software management of resources from within the VXI environment. The paper will concentrate mainly on the latter areas. (author)

  15. Airborne gamma-ray spectrometer and magnetometer survey, Wainwright Quadrangle, Alaska. Final report

    International Nuclear Information System (INIS)

    1981-03-01

    The results obtained from a gamma-ray spectrometer and magnetometer survey over the Wainwright map area of Alaska are presented. Based on the criteria outlined in the general section of interpretation, a total of seven uranium anomalies have been outlined on the interpretation map. With the exception of Anomaly 1, all are located over the higher terrain of the foothills in the southern portion of the quadrangle. All seven anomalies are only weakly to moderately anomalous. There are no indications anywhere within the area of any significant preferential accumulations of uranium. None of the anomalies are thought to be of any economic importance. No follow-up work is recommended

  16. Model H-90A gamma-ray spectrometer with microcomputer

    International Nuclear Information System (INIS)

    Zhang Biao; Dong Chen; Zhao Zhiming

    1994-11-01

    Model H-90A is a 4-channel differential Gamma-ray spectrometer with microcomputer. It consists of a console and NaI(TL) crystal detector with a diameter of φ75 mm x 75 mm. The instrument has excellent performance such as automatic spectrum stabilization, automatic regular timing measurement and automatic calculation of uranium, thorium and potassium contents and their ratios. Original data can be manually and automatically stored. The instrument is provided with shut down supply protective device, reading out can be repeated or be further processed through RS-232 interface output in the case of connection with computer. The working command is inputted by 'soft key' and performed by slice microcomputer automatically through software. It can be used not only in radioactive geological mapping, geochemical research and rapid field assay of radioactive elements in mineral and rock samples, but also for exploration and reconnaissance survey for uranium, thorium, potassium and seeking gold, as well as environmental monitoring

  17. Assessment of background gamma radiation levels using airborne gamma ray spectrometer data over uranium deposits, Cuddapah Basin, India - A comparative study of dose rates estimated by AGRS and PGRS.

    Science.gov (United States)

    Srinivas, D; Ramesh Babu, V; Patra, I; Tripathi, Shailesh; Ramayya, M S; Chaturvedi, A K

    2017-02-01

    The Atomic Minerals Directorate for Exploration and Research (AMD) has conducted high-resolution airborne gamma ray spectrometer (AGRS), magnetometer and time domain electromagnetic (TDEM) surveys for uranium exploration, along the northern margins of Cuddapah Basin. The survey area includes well known uranium deposits such as Lambapur-Peddagattu, Chitrial and Koppunuru. The AGRS data collected for uranium exploration is utilised for estimating the average absorbed rates in air due to radio-elemental (potassium in %, uranium and thorium in ppm) distribution over these known deposit areas. Further, portable gamma ray spectrometer (PGRS) was used to acquire data over two nearby locations one from Lambapur deposit, and the other from known anomalous zone and subsequently average gamma dose rates were estimated. Representative in-situ rock samples were also collected from these two areas and subjected to radio-elemental concentration analysis by gamma ray spectrometer (GRS) in the laboratory and then dose rates were estimated. Analyses of these three sets of results complement one another, thereby providing a comprehensive picture of the radiation environment over these deposits. The average absorbed area wise dose rate level is estimated to be 130 ± 47 nGy h -1 in Lambapur-Peddagattu, 186 ± 77 nGy h -1 in Chitrial and 63 ± 22 nGy h -1 in Koppunuru. The obtained average dose levels are found to be higher than the world average value of 54 nGy h -1 . The gamma absorbed dose rates in nGy h -1 were converted to annual effective dose rates in mSv y -1 as proposed by the United Nations Scientific Committee on the Effect of Atomic Radiation (UNSCEAR). The annual average effective dose rates for the entire surveyed area is 0.12 mSv y -1 , which is much lower than the recommended limit of 1 mSv y -1 by International Commission on Radiation protection (ICRP). It may be ascertained here that the present study establishes a reference data set (baseline) in these areas

  18. The design and evaluation of a selectively modulated interferometric dispersive spectrometer

    International Nuclear Information System (INIS)

    Fitzgerald, J.J.

    1986-01-01

    In approaching the problem of rapid simultaneous multielement analysis, the large light gathering power, wide spectral range and high resolution of a Fourier Transform Spectrometer (FTS) should be of benefit. The severe mechanical tolerances required in the construction and operation of a classical Michelson interferometer for use in the UV-Visible spectral region have limited investigations in the application of simultaneous trace quantitative analysis. Theory is presented demonstrating that replacement of the fixed mirror in one arm of the Michelson interferometer with a rotating grating preserves most of the FTS advantages and results in a greatly simplified detector system. No mathematical Fourier transform is required. The need for a computer is eliminated. An instrument, SEMIDS (Selectively Modulated Interferometric Dispersive Spectrometer), was constructed to investigate the mathematical model. Design criteria and basic operational performance as a flame emission spectrometer are presented. SEMIDS achieved high resolution, high throughput and greatly simplified operation compared to a Michelson interferometer. Performance as a trace quantitative tool was disappoint because of unanticipated noise contributions from flame background. A summary of the noise component contributions is discussed

  19. Electronic module for control of sample feeding device of spectrometers of X-ray fluorescent analysis of CRV type

    International Nuclear Information System (INIS)

    Petrov, V.A.; Fursov, A.V.

    2002-01-01

    The scheme of electronic module for sample feeding device control for the CRV type X-ray fluorescence analysis spectrometers is considered. This module provides realization of next functions: sample change operations and installation in starting position; signaling and defense at emergency cases; indication of any sample amount in the spectrometer chamber; testing function at tuning and testing of modules. All these principal functions are entrusted with microcontroller. Programming of the microcontroller is putting into effect by algorithm of the whole sample feeding device. In the capacity of microcontroller the single crystalline processor PICI16C54 and stepping motor of NV-306-V2202 model have been used

  20. Performance of the prototype LaBr{sub 3} spectrometer developed for the JET gamma-ray camera upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Rigamonti, D., E-mail: davide.rigamonti@mib.infn.it; Nocente, M.; Gorini, G. [Dipartimento di Fisica “G. Occhialini,” Università degli Studi di Milano-Bicocca, Milano (Italy); Istituto di Fisica del Plasma “P. Caldirola,” CNR, Milano (Italy); Muraro, A.; Giacomelli, L.; Cippo, E. P.; Tardocchi, M. [Istituto di Fisica del Plasma “P. Caldirola,” CNR, Milano (Italy); Perseo, V. [Dipartimento di Fisica “G. Occhialini,” Università degli Studi di Milano-Bicocca, Milano (Italy); Boltruczyk, G.; Gosk, M.; Korolczuk, S.; Mianowski, S.; Zychor, I. [Narodowe Centrum Badań Jądrowych (NCBJ), 05-400 Otwock-Swierk (Poland); Fernandes, A.; Pereira, R. C. [Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Universidade de Lisboa, Lisboa (Portugal); Figueiredo, J. [Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Universidade de Lisboa, Lisboa (Portugal); EUROfusion Programme Management Unit, Culham Science Centre, OX14 3DB Abingdon (United Kingdom); Kiptily, V. [Culham Science Centre for Fusion Energy, Culham (United Kingdom); Murari, A. [EUROfusion Programme Management Unit, Culham Science Centre, OX14 3DB Abingdon (United Kingdom); Consorzio RFX (CNR, ENEA, INFN, Universita’ di Padova, Acciaierie Venete SpA), Padova (Italy); Collaboration: EUROfusion Consortium, JET, Culham Science Centre, Abingdon OX14 3DB (United Kingdom)

    2016-11-15

    In this work, we describe the solution developed by the gamma ray camera upgrade enhancement project to improve the spectroscopic properties of the existing JET γ-ray camera. Aim of the project is to enable gamma-ray spectroscopy in JET deuterium-tritium plasmas. A dedicated pilot spectrometer based on a LaBr{sub 3} crystal coupled to a silicon photo-multiplier has been developed. A proper pole zero cancellation network able to shorten the output signal to a length of 120 ns has been implemented allowing for spectroscopy at MHz count rates. The system has been characterized in the laboratory and shows an energy resolution of 5.5% at E{sub γ} = 0.662 MeV, which extrapolates favorably in the energy range of interest for gamma-ray emission from fast ions in fusion plasmas.

  1. Progress with the Konus-W gamma-ray burst spectrometer on GGS-Wind

    International Nuclear Information System (INIS)

    Mazets, E. P.; Aptekar, R. L.; Frederiks, D. D.; Golenetskii, S. V.; Ilynskii, V. N.; Terekhov, M. M.; Cline, T. L.; Butterworth, P. S.; Stilwell, D. E.

    1996-01-01

    The cosmic gamma-ray burst spectrometer Konus-W has been successfully making observations for nearly one year, since the launch of the GGS-Wind spacecraft. The instrument consists of two large scintillator units of size and shape very nearly the same as the spectroscopy detectors on CGRO BATSE. These face towards the ecliptic poles so as to survey the sky in a moderately uniform fashion. At least 114 gamma ray bursts have triggered the system in the first 330 days of operation, yielding detailed time histories and spectra. A large number of additional events are seen in the background mode at much coarser resolution. These observations can be combined with those of the Interplanetary Network to reduce the total area of the segmented annular source fields derived from several degrees to about one degree in length, although the data cannot obtained from this spacecraft in the rapid turnaround mode needed to benefit the BACODINE system. The Konus spectra can be summarized presently as providing little indication of the frequent occurrence of major spectral features

  2. Use of microcontroller in gamma-ray spectrometer construction using NaI(Tl) sensor, with emphasis in multichannel analyzer, to applications in nuclear and environmental geophysics

    International Nuclear Information System (INIS)

    Silva, Nilton

    2005-01-01

    In this work of nuclear geophysical instrumentation the main purpose was the development of a gamma-ray spectrometer prototype with multi channel analyzer, since the spectroscopic amplifier until your firmware. The heart of the digital part was an ATMEL 8 bits microcontroller (AT89S8252). All circuits were made and assembled in the Laboratory of Applied Geophysical Instrumentation (LIGA) of IAG-USP. A microcontroller software was completely developed in C ANSI language using the Small Device C Compiler version 2.4.8, that is a free software distributed under General Public License (GPL). At first, microcontroller was used to change all digital circuit of one classic SCINTREX GAD-6 differential gamma-ray spectrometer. Measurement times with order of 2 days became possible, and it could work in non climate ambient. Then, after this stage, had been started the development of a multichannel analyzer (MCA) working in pulse height analyzer mode with 4096 channels capacity, to use in many kinds of nuclear detection. Besides it, was developed an automatic gain system for photopeak stabilization, by the use of one radioactive source ( 133 Ba). This automatic gain system is very important in the case of NaI(Tl) scintillometric detectors, due PMT sensitivity with temperature and aging of some laboratory electronic circuits. Two power supplies with high stability, using pulse width modulation (PWM) techniques were developed, in order to all system became free of electrical line break off. One PWM power polarizes a photo multiplier tube (PMT) with high voltage and another supplies remaining developed circuits. Calibration in energy using standards sources 137 Cs and 60 Co showed that gamma detector developed has a good linearity and low thermal drift, even working in absent of air-conditioned. Concentrations measurements of K, U and Th were made in samples of soils, vegetables, etc. (author)'

  3. Qualification study of LiF flight crystals for the objective crystal spectrometer on the SPECTRUM-X-GAMMA satellite

    DEFF Research Database (Denmark)

    Christensen, Finn Erland; Rasmussen, I.; Schnopper, Herbert W.

    1992-01-01

    The Objective Crystal Spectrometer (OXS) on the SPECTRUM-X-GAMMA satellite will carry these types of natural crystals LiF(220), Ge(111) and RAP(001). They will be used to study, among others, the H- and the He-like emission from the cosmically important elements Fe, S, Ar and O. More than 300 Li...

  4. Investigation of epigenetic gene regulation in Arabidopsis modulated by gamma radiation

    International Nuclear Information System (INIS)

    Woo, Hye Ryun; Kim, Jae Sung; Lee, Myung Jin; Lee, Dong Joon; Kim, Young Min; Jung, Joon Yong; Han, Wan Keun; Kang, Soo Jin

    2011-12-01

    To investigate epigenetic gene regulation in Arabidopsis modulated by gamma radiation, we examined the changes in DNA methylation and histone modification after gamma radiation and investigated the effects of gamma radiation on epigenetic information and gene expression. We have selected 14 genes with changes in DNA methylation by gamma radiation, analyzed the changes of histone modification in the selected genes to reveal the relationship between DNA methylation and histone modification by gamma radiation. We have also analyzed the effects of gamma radiation on gene expression to investigate the relationship between epigenetic information and gene expression by gamma radiation. The results will be useful to reveal the effects of gamma radiation on DNA methylation, histone modification and gene expression. We anticipate that the information generated in this proposal will help to find out the mechanism underlying the changes in epigenetic information by gamma radiation

  5. Evidence for solar flare directivity from the Gamma-Ray Spectrometer aboard the SMM satellite

    Science.gov (United States)

    Vestrand, W. T.; Forrest, D. J.; Chupp, E. L.; Rieger, E.; Share, G. H.

    1986-01-01

    A number of observations from the SMM Gamma-Ray Spectrometer are presented that altogether strongly indicate that the high-energy emission from flares is anisotropic. They are: (1) the fraction of events detected at energies above 300 keV near the limb is significantly higher than is expected for isotropically emitting flares; (2) there is a statistically significant center-to-limb variation in the 300-1000-keV spectra of flares; and (3) nearly all of the events detected at above 10 MeV are located near the limb.

  6. Stabilization of spectra provided by a gamma-ray spectrometer. Application to the construction of a stabilizer

    International Nuclear Information System (INIS)

    Detourne, G.

    1967-06-01

    This research is concerned with the stabilization of spectra provided by a gamma-ray spectrometer. It is required to hold the calibration straight line of the spectrometer in a position which is fixed initially to better than 5x10 -5 channel. A prototype numerical stabilizer has been constructed : the SPECTROSTAB; it is made up of two independent control loops; one of these makes the spectrometer gain depend on the derivatives of a reference peak at high energies; the other makes the origin of the energy scale depend on the derivatives of a second reference peak at low energies A theoretical study of the behaviour of a control loop shows that a direct action stabilizer gives the most accurate stabilization; the loss in resolving power on the theoretical peaks of the spectra attains about 1 % with a scintillation detector, and 10 % with a semi-conductor detector. Various tests show that the expected results are obtained and that the displacement of the spectral peaks produced by the derivatives are hidden by errors in the calculation of the peak abscissae. (author) [fr

  7. Distributed Attention Is Implemented through Theta-Rhythmic Gamma Modulation.

    Science.gov (United States)

    Landau, Ayelet Nina; Schreyer, Helene Marianne; van Pelt, Stan; Fries, Pascal

    2015-08-31

    When subjects monitor a single location, visual target detection depends on the pre-target phase of an ∼8 Hz brain rhythm. When multiple locations are monitored, performance decrements suggest a division of the 8 Hz rhythm over the number of locations, indicating that different locations are sequentially sampled. Indeed, when subjects monitor two locations, performance benefits alternate at a 4 Hz rhythm. These performance alternations were revealed after a reset of attention to one location. Although resets are common and important events for attention, it is unknown whether, in the absence of resets, ongoing attention samples stimuli in alternation. Here, we examined whether spatially specific attentional sampling can be revealed by ongoing pre-target brain rhythms. Visually induced gamma-band activity plays a role in spatial attention. Therefore, we hypothesized that performance on two simultaneously monitored stimuli can be predicted by a 4 Hz modulation of gamma-band activity. Brain rhythms were assessed with magnetoencephalography (MEG) while subjects monitored bilateral grating stimuli for a unilateral target event. The corresponding contralateral gamma-band responses were subtracted from each other to isolate spatially selective, target-related fluctuations. The resulting lateralized gamma-band activity (LGA) showed opposite pre-target 4 Hz phases for detected versus missed targets. The 4 Hz phase of pre-target LGA accounted for a 14.5% modulation in performance. These findings suggest that spatial attention is a theta-rhythmic sampling process that is continuously ongoing, with each sampling cycle being implemented through gamma-band synchrony. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Gamma-gamma angular correlation measurement in the 100 Ru

    International Nuclear Information System (INIS)

    Kenchian, G.

    1990-01-01

    An angular correlation automatic spectrometer with two Ge(Li) detectors has been developed. The spectrometer moves automatically, controlled by a microcomputer. The gamma-gamma directional angular correlations of coincidence transitions have been measured in 100 Ru nuclide, following the β + and electron capture of 100 Rh. The 100 Rh source has been produced with 100 Ru(p,n) 100 Rh reaction, using the proton beam of the Cyclotron Accelerator insiding in 100 Ru isotope. (author)

  9. Airborne gamma-ray spectrometer and magnetometer survey: Aberdeen quadrangle, South Dakota. Final report

    International Nuclear Information System (INIS)

    1981-04-01

    During the months of June through October, 1980, Aero Service Division Western Geophysical Company of America conducted an airborne high sensitivity gamma-ray spectrometer and magnetometer survey over eleven (11) 2 0 x 1 0 NTMS quadrangles located in the states of Minnesota and Wisconsin and seven (7) 2 0 x 1 0 NTMS quadrangles in North and South Dakota. This report discusses the results obtained over the Aberdeen, South Dakota map area. The final data are presented in four different forms: on magnetic tape; on microfiche; in graphic form as profiles and histograms; and in map form as anomaly maps, flight path maps, and computer printer maps

  10. Shifts of Gamma Phase across Primary Visual Cortical Sites Reflect Dynamic Stimulus-Modulated Information Transfer.

    Science.gov (United States)

    Besserve, Michel; Lowe, Scott C; Logothetis, Nikos K; Schölkopf, Bernhard; Panzeri, Stefano

    2015-01-01

    Distributed neural processing likely entails the capability of networks to reconfigure dynamically the directionality and strength of their functional connections. Yet, the neural mechanisms that may allow such dynamic routing of the information flow are not yet fully understood. We investigated the role of gamma band (50-80 Hz) oscillations in transient modulations of communication among neural populations by using measures of direction-specific causal information transfer. We found that the local phase of gamma-band rhythmic activity exerted a stimulus-modulated and spatially-asymmetric directed effect on the firing rate of spatially separated populations within the primary visual cortex. The relationships between gamma phases at different sites (phase shifts) could be described as a stimulus-modulated gamma-band wave propagating along the spatial directions with the largest information transfer. We observed transient stimulus-related changes in the spatial configuration of phases (compatible with changes in direction of gamma wave propagation) accompanied by a relative increase of the amount of information flowing along the instantaneous direction of the gamma wave. These effects were specific to the gamma-band and suggest that the time-varying relationships between gamma phases at different locations mark, and possibly causally mediate, the dynamic reconfiguration of functional connections.

  11. Airborne gamma-ray spectrometer and magnetometer survey, Point Lay Quadrangle, Alaska. Volume I. Final report

    International Nuclear Information System (INIS)

    1981-02-01

    The results obtained from an airborne high sensitivity gamma-ray spectrometer and magnetometer survey over the Point Lay map area of Alaska are presented. Based on the criteria outlined in the general section on interpretation, a total of six uranium anomalies have been indicated on the interpretation map. All six are only weakly to moderately anomalous in either uranium or the uranium ratios. None of these are thought to be of any economic significance. No follow-up work is recommended for the Point Lay Quadrangle

  12. Airborne gamma-ray spectrometer and magnetometer survey: Harrison Bay Quadrangle, Alaska. Final report, Volume 1

    International Nuclear Information System (INIS)

    1981-02-01

    During the months of July and August of 1980, Aero Service Division Western Geophysical Company of America conducted an airborne high sensitivity gamma-ray spectrometer and magnetometer survey over eleven (11) 3 0 x 1 0 and one (1) 4 0 x 1 0 NTMS quadrangles of the Alaska North Slope. These include the Barrow, Wainwright, Meade River, Teshekpuk, Harrison Bay, Beechey Point, Point Lay, Utukok River, Lookout Ridge, Ikpikpuk River, Umiat, and Sagavanirktok quadrangles. This report discusses the results obtained over the Harrison Bay map area

  13. Gamma spectrometric system based on the personal computer Pravetz-83

    International Nuclear Information System (INIS)

    Yanakiev, K; Grigorov, T.; Vuchkov, M.

    1985-01-01

    A gamma spectrometric system based on a personal microcomputer Pravets-85 is described. The analog modules are NIM standard. ADC data are stored in the memory of the computer via a DMA channel and a real-time data processing is possible. The results from a series of tests indicate that the performance of the system is comparable with that of comercially avalable computerized spectrometers Ortec and Canberra

  14. Soft X-ray Calibration of the Co/C Multilayer Mirrors for the Objective Crystal Spectrometer on the Spectrum Röntgen-Gamma Satellite

    DEFF Research Database (Denmark)

    Abdali, Salim; Tarrio, C.; Christensen, Finn Erland

    1996-01-01

    The objective crystal spectrometer (OXS) on the forthcoming Spectrum-Roentgen-Gamma satellite is designed to carry three kinds of crystals: LiF(220), Si(111) and RAP(001), placed in front of the SODART telescope. Thirty six super polished (RMS roughness

  15. The calibration of portable and airborne gamma-ray spectrometers - theory, problems, and facilities

    International Nuclear Information System (INIS)

    Loevborg, L.

    1984-10-01

    A gamma-ray spectrometer for use in geological exploration possesses four stripping ratios and three window sensitivities which must be determined to make the instrumentation applicable for field assay or airborne measurement of potassium, uranium, and thorium contents in the ground. Survey organizations in many parts of the world perform the instrument calibration using large pads of concrete which simulate a plane ground of known radioelement concentration. Calibration and monitoring trials with twelve facilities in ten countries prove that moisture absorption, radon exhalation, and particle-size effects can offset a radiometric grade assigned to concrete whose aggregate contains an embedded radioactive mineral. These and other calibration problems are discussed from a combined theoretical and practical viewpoint. (author)

  16. GammaLog Playback 1.0 - mobile gamma ray spectrometry software

    International Nuclear Information System (INIS)

    Watson, R.J.; Smethurst, M.A.

    2011-01-01

    The Geological Survey of Norway (NGU) operates a mobile gamma ray spectrometer system which can be used in nuclear emergency situations to determine the location and type of orphan sources, or the extent and type of fallout contamination. The system consists of a 20 litre (16 litre downward and 4 litre upward looking) RSX-5 NaI detector and spectrometer, and can be mounted in fixed wing aircraft, helicopters, or vans/cars as appropriate. NGU has developed its own data acquisition and analysis software for this system. GammaLog (Smethurst 2005) controls the acquisition, display, and storage of data from the spectrometer, and performs real-time data analysis including estimation of dose rates and fallout concentrations, and separation of geological and anthropogenic components of the signal. The latter is particularly important where the geological radioisotope signal varies strongly from one place to another, and makes it easier to locate and identify anthropogenic sources which might otherwise be difficult to separate from the geological background signal. A modified version of GammaLog has been developed, GammaLog Playback, which allows the replay of previously acquired GammaLog datasets, while performing similar processing and display as the GammaLog acquisition software. This allows datasets to be reviewed and compared in the field or during post-survey analysis to help plan subsequent measurement strategies.(Au)

  17. Conceptual design of the Radial Gamma Ray Spectrometers system for α particle and runaway electron measurements at ITER

    DEFF Research Database (Denmark)

    Nocente, Massimo; Tardocchi, Marco; Barnsley, Robin

    2017-01-01

    We here present the principles and main physics capabilities behind the design of the radial gamma ray spectrometers (RGRS) system for alpha particle and runaway electron measurements at ITER. The diagnostic benefits from recent advances in gamma-ray spectrometry for tokamak plasmas and combines...... the measurements sensitive to α particles at characteristic resonant energies and to possible anisotropies of their slowing down distribution function. An independent assessment of the neutron rate by gamma-ray emission is also feasible. In case of runaway electrons born in disruptions with a typical duration...... of 100ms, a time resolution of at least 10ms for runaway electron studies can be achieved depending on the scenario and down to a current of 40 kA by use of external gas injection. We find that the bremsstrahlung spectrum in the MeV range from confined runaways is sensitive to the electron velocity space...

  18. Technology information profile: RL321103 -- In situ gamma spectrometer

    International Nuclear Information System (INIS)

    Schilk, A.J.

    1993-11-01

    Past operations of uranium production and support facilities at several Department of Energy (DOE) sites have occasionally resulted in the local contamination of some surface and subsurface soils. Such contamination commonly occurs within waste burial sites, cribs, pond bottom sediments, and areas surrounding waste tanks or uranium scrap, ore, tailing, and slag heaps. The thorough cleanup of these sites is a major public concern and a high priority for the DOE, but before any effective remedial protocols can be established, the three-dimensional distributions of the uranium contaminants must be adequately characterized. Unfortunately, traditional means of obtaining soil activities (e.g., grab sampling followed by laboratory analyses) are notoriously cumbersome, expensive, time-consuming, and often non-representative when very large areas are being surveyed. Hence, new technologies must be developed, or existing ones improved, to allow for the cheaper, better, faster (i.e., real-time) and safer characterization of uranium concentrations at these critical sites. The primary objective for this program is to develop, construct, and field/pilot test the in situ gamma spectrometer for the rapid measurement of uranium in surface and shallow subsurface soils at the Fernald site in Ohio

  19. Dosimetry computer module of the gamma irradiator of ININ

    International Nuclear Information System (INIS)

    Ledezma F, L. E.; Baldomero J, R.; Agis E, K. A.

    2012-10-01

    This work present the technical specifications for the upgrade of the dosimetry module of the computer system of the gamma irradiator of the Instituto Nacional de Investigaciones Nucleares (ININ) whose result allows the integration and consultation of information in industrial dosimetry subject under an outline client-server. (Author)

  20. Airborne gamma-ray spectrometer and magnetometer survey, Devils Lake quadrangle, North Dakota. Final report

    International Nuclear Information System (INIS)

    1981-05-01

    During the months of June through October, 1980, Aero Service Division Western Geophysical Company of America conducted an airborne high sensitivity gamma-ray spectrometer and magnetometer survey over eleven (11) 2 0 x 1 0 NTMS quadrangles located in the states of Minnesota and Wisconsin and seven (7) 2 0 x 1 0 NTMS quadrangles in North and South Dakota. This report discusses the results obtained over the Devil's Lake map area of North Dakota. The final data are presented in four different forms: on magnetic tape; on microfiche; in graphic form as profiles and histograms; and in map form as anomaly maps, flight path maps, and computer printer maps

  1. Methods for fitting of efficiency curves obtained by means of HPGe gamma rays spectrometers

    International Nuclear Information System (INIS)

    Cardoso, Vanderlei

    2002-01-01

    The present work describes a few methodologies developed for fitting efficiency curves obtained by means of a HPGe gamma-ray spectrometer. The interpolated values were determined by simple polynomial fitting and polynomial fitting between the ratio of experimental peak efficiency and total efficiency, calculated by Monte Carlo technique, as a function of gamma-ray energy. Moreover, non-linear fitting has been performed using a segmented polynomial function and applying the Gauss-Marquardt method. For the peak area obtainment different methodologies were developed in order to estimate the background area under the peak. This information was obtained by numerical integration or by using analytical functions associated to the background. One non-calibrated radioactive source has been included in the curve efficiency in order to provide additional calibration points. As a by-product, it was possible to determine the activity of this non-calibrated source. For all fittings developed in the present work the covariance matrix methodology was used, which is an essential procedure in order to give a complete description of the partial uncertainties involved. (author)

  2. Studies of the $\\beta$-decay of Sr nuclei on and near the N=Z Line with a Total Absorption Gamma-ray Spectrometer

    CERN Multimedia

    Marechal, F; Caballero ontanaya, L

    2002-01-01

    In the framework of the investigation of the shapes of the ground states of the parent nucleus, we propose to carry out measurements of the complete Gamow-Teller strength distribution for the $^{76-80}$Sr isotopes, with a new Total Absorption Gamma Spectrometer installed on a new beam line. The results will be compared with theoretical calculations based on the mean field approach. A brief report on the IS370 experiment on $^{72-75}$Kr decay, which was recently performed at ISOLDE, will be given and the performance of the sum spectrometer will be presented.

  3. Radioactivity observed in the sodium iodide gamma-ray spectrometer returned on the Apollo 17 mission

    Science.gov (United States)

    Dyer, C. S.; Trombka, J. I.; Schmadebeck, R. L.; Eller, E.; Bielefeld, M. J.; Okelley, G. D.; Eldridge, J. S.; Northcutt, K. J.; Metzger, A. E.; Reedy, R. C.

    1975-01-01

    In order to obtain information on radioactive background induced in the Apollo 15 and 16 gamma-ray spectrometers (7 cm x 7 cm NaI) by particle irradiation during spaceflight, and identical detector was flown and returned to earth on the Apollo 17 mission. The induced radioactivity was monitored both internally and externally from one and a half hours after splashdown. When used in conjunction with a computation scheme for estimating induced activation from calculated trapped proton and cosmic-ray fluences, these results show an important contribution resulting from both thermal and energetic neutrons produced in the heavy spacecraft by cosmic-ray interactions.

  4. On calculation of detection efficiency of gamma spectrometers with germanium detection

    International Nuclear Information System (INIS)

    Sima, O.

    2001-01-01

    High resolution gamma spectrometer represents a powerful analysis technique of use in various fields from basic research to the study of environmental radioactivity, from medical investigations to geological surveys. Direct experimental calibration cannot cover the large range of measurement configurations of interest. Actually, it can be appropriately applied in an only limited number of cases, as for instance, in case of point-like sources or liquid phase volume sources. To assist the treatment of experimental calibration of germanium detectors, in the frame of Atomic and Nuclear Physics Chair of Department of Physics, a number of calculation methods were developed. These methods are generally based on Monte Carlo simulation but simplified and fast analytical methods were also worked out. Initially, these studies were dedicated to application in the field of environmental activity and radiation protection, but later on these were extended also to other fields as, for instance, the neutron activation or radionuclide metrology. First, the effects of matrices were calculated for the case of volume sources. Applying the matrix corrections allows obtaining the source calibration curves on the basis of experimental calibration data obtained with liquid sources, in the same geometry. An algorithm based on Monte Carlo calculation and using techniques of correlated selection was obtained. This algorithm can be implemented in the gamma analysis programs giving for the first time the possibility of correct evaluation of matrix effects even during the analysis of gamma spectra. We used a set of additive relations applicable in case of volume sources with negligible self-absorption and obtained a number of linear relations useful in calibrating the large volume sources in presence of self-absorption, based on small volume standard sources. Also, we proposed analytical relations useful in the case of measurements of large volume samples, in case of Marinelli geometry. To

  5. Large-volume and room-temperature gamma spectrometer for environmental radiation monitoring

    Directory of Open Access Journals (Sweden)

    Romain Coulon

    2017-10-01

    Full Text Available The use of a room-temperature gamma spectrometer is an issue in environmental radiation monitoring. To monitor radionuclides released around a nuclear power plant, suitable instruments giving fast and reliable information are required. High-pressure xenon (HPXe chambers have range of resolution and efficiency equivalent to those of other medium resolution detectors such as those using NaI(Tl, CdZnTe, and LaBr3:Ce. An HPXe chamber could be a cost-effective alternative, assuming temperature stability and reliability. The CEA LIST actively studied and developed HPXe-based technology applied for environmental monitoring. Xenon purification and conditioning was performed. The design of a 4-L HPXe detector was performed to minimize the detector capacitance and the required power supply. Simulations were done with the MCNPX2.7 particle transport code to estimate the intrinsic efficiency of the HPXe detector. A behavioral study dealing with ballistic deficits and electronic noise will be utilized to provide perspective for further analysis.

  6. New detection modules for gamma, beta and X-ray cameras

    International Nuclear Information System (INIS)

    Azman, S.; Bolle, E.; Dang, K.Q.; Dang, W.; Dietzel, K.I.; Froberg, T.; Gaarder, P.E.; Gjaerum, J.A.; Haugen, S.H.; Hellum, G.; Henriksen, J.R.; Johanson, T.M.; Kobbevik, A.; Maehlum, G.; Meier, D.; Mikkelsen, S.; Ninive, I.; Oya, P.; Pavlov, N.; Pettersen, D.M.; Sundal, B.M.; Talebi, J.; Yoshioka, K.

    2003-01-01

    Full text: Ideas ASA is developing new detection modules for gamma, beta and X-ray cameras. Recent developments focus on modules using various semi-conductor materials (CZT, HgI, Si). The development includes ASIC design, detector module development, and implementation in camera heads. In this presentation we describe the characteristics of important ASICs and its properties in terms of electronic noise, and the modes for measuring signals (switched current modes, sparsified modes, self triggered modes). The ASICs are specific for detectors and applications. We describe recent developments using various semi - conductor materials. We describe important design aspects for medical applications and in life science (SPECT, beta, X-ray cameras)

  7. BER of subcarrier MPSK/MDPSK modulated OWC systems in Gamma-Gamma turbulence

    KAUST Repository

    Song, Xuegui

    2013-12-01

    Bit-error rate (BER) performance of subcarrier Mary phase-shift keying (MPSK) and M-ary differential PSK (MDPSK) is analyzed for optical wireless communications in Gamma-Gamma turbulence. We study the relation between the exact BER and the approximate BER, which is obtained by dividing the symbol error rate by the number of bits per symbol, for subcarrier MPSK and MDPSK modulations. The asymptotic performance gap between the exact and the approximate BERs is quantified analytically through our asymptotic analyses. The accuracy of the approximate BER of both MPSK and MDPSK depends on the channel conditions. Under weak turbulence conditions, the approximate BER expression can be used to predict the system performance with high accuracy, while under strong turbulence conditions the approximate BER becomes inaccurate and can only serve as a loose lower bound of the exact BER. The asymptotic BER performance loss of MDPSK with respect to MPSK is also quantified analytically. © 2013 IEEE.

  8. A digital multi-channel spectroscopy system with 100 MHz flash ADC module for the GENIUS-TF and GENIUS projects

    International Nuclear Information System (INIS)

    Kihm, T.; Bobrakov, V.F.; Klapdor-Kleingrothaus, H.V.

    2003-01-01

    In this paper we present the first results of applying a digital processing technology in low-level gamma spectroscopy with HPGE detectors. An experimental gamma spectrometer using Flash ADC module is built and tested. The test system is now under development and shows major advantages over the traditional analog technologies. It will be installed for the GENIUS-TF and GENIUS projects in Gran-Sasso in early 2003

  9. Approaches to contamination problems of agricultural land using Na(I) Tl spectrometer and gamma camera

    International Nuclear Information System (INIS)

    Yin, Yong-Gen; Suzui, Nobuo; Kawachi, Naoki; Ishii, Satomi; Fujimaki, Shu; Yamaguchi, Mitsutaka; Tanoi, Keitaro; Nakanishi, Tomoko M.; Chino, Mitsuo; Nakamura, Shin-ichi; Watabe, Hiroshi; Yamamoto, Seiichi

    2012-01-01

    The severe accident of Fukushima Daiichi Nuclear Power Plant made a large area of agricultural land contaminated with radioactive cesium (Cs-134 and 137). Quantitative analysis for radioactivity (discriminating for Cs-134 and Cs-137) taken in vegetables from the land was carried out using NaI (Tl) scintillation spectrometer. Development of gamma camera for their imaging due to Cs 137 was performed. The shape of the peaks in the spectrum, baseline suppression, a solution of lines overlapping, enhancement of high-resolution were studied. Furthermore, the effect of water on cesium absorbing and transferring process from the root to the tissue was studied. (S. Ohno)

  10. Multilayer x-ray mirrors for the objective crystal spectrometer on the Spectrum Roentgen Gamma satellite

    DEFF Research Database (Denmark)

    Louis, E.; Spiller, E.; Abdali, S.

    1995-01-01

    with Kr+- and Ar+- ions of 300, 500, and 1000 eV. We examined the effect of different polishing parameters on the smoothening of the Co- and Ni-layers. The in-situ reflectivity of lambda equals 3.16 nm during deposition and the ex-situ grazing incidence reflectivity of Cu-K(alpha ) radiation (lambda...... multiplied by 6 cm2 Si (111) crystals for the Objective Crystal Spectrometer on the Russian Spectrum Rontgen Gamma satellite. The coatings on the flight crystals have a period Lambda of 3.95 plus or minus 0.02 nm and a reflectivity of more than 8% averaged over s- and p-polarization over the entire...

  11. Search for Doppler-shifted gamma-ray emission from SS 433 using the SMM spectrometer

    International Nuclear Information System (INIS)

    Geldzahler, B.J.; Share, G.H.; Kinzer, R.L.; Magura, J.; Chupp, E.L.

    1989-01-01

    Data accumulated from 1980 to 1983 with the Gamma Ray Spectrometer aboard NASA's Solar Maximum Mission (SMM) satellite were searched for evidence of red and blue Doppler-shifted 1.37 MeV Mg-24 nuclear lines from SS 433. The SMM data base covers 270 days when SS 433 was in the field of view and includes periods of radio flaring and quiescence. No evidence was found for Doppler-shifted line emission in any of the spectra. The range of 3-sigma upper limits for individual 9 day integration periods was 0.0008-0.0023 photons/sq cm per sec for the blue beam, encompassing the reported about 1.5 MeV line, and 0.0008-0.002 photons/sq cm per sec for the red beam, encompassing the reported about 1.2 MeV line; the average 3-sigma upper limit in each beam for shifted about 1.37 MeV lines is 0.0015 photons/sq cm per sec for single 9 day integrations. The 3-sigma upper limit on 1.37 MeV gamma-ray emission over 23 9-day integration intervals for the red beam and 28 intervals for the blue beam is 0.0002 photons/sq cm per sec. These new limits from SMM can be reconciled with the HEAO 3 results only if SS 433 emits gamma radiation at or above the SMM sensitivity limit on rare occasions due to variable physical conditions in the system. 19 refs

  12. Search for Doppler-shifted gamma-ray emission from SS 433 using the SMM spectrometer

    Science.gov (United States)

    Geldzahler, B. J.; Share, G. H.; Kinzer, R. L.; Magura, J.; Chupp, E. L.

    1989-01-01

    Data accumulated from 1980 to 1983 with the Gamma Ray Spectrometer aboard NASA's Solar Maximum Mission (SMM) satellite were searched for evidence of red and blue Doppler-shifted 1.37 MeV Mg-24 nuclear lines from SS 433. The SMM data base covers 270 days when SS 433 was in the field of view and includes periods of radio flaring and quiescence. No evidence was found for Doppler-shifted line emission in any of the spectra. The range of 3-sigma upper limits for individual 9 day integration periods was 0.0008-0.0023 photons/sq cm per sec for the blue beam, encompassing the reported about 1.5 MeV line, and 0.0008-0.002 photons/sq cm per sec for the red beam, encompassing the reported about 1.2 MeV line; the average 3-sigma upper limit in each beam for shifted about 1.37 MeV lines is 0.0015 photons/sq cm per sec for single 9 day integrations. The 3-sigma upper limit on 1.37 MeV gamma-ray emission over 23 9-day integration intervals for the red beam and 28 intervals for the blue beam is 0.0002 photons/sq cm per sec. These new limits from SMM can be reconciled with the HEAO 3 results only if SS 433 emits gamma radiation at or above the SMM sensitivity limit on rare occasions due to variable physical conditions in the system.

  13. An Analysis on Some Factors Which Affect the Energy Resolution of a Low-background Anti-compton HPGe Gamma-ray Spectrometer

    International Nuclear Information System (INIS)

    Zhou Chunlin; Dai Junjie; Lei Junniu; Zhang Jiaoyu

    2009-01-01

    This paper describes the basic construction and performing theory of a set of low-background anti-compton high purity germanium gamma-ray spectrometer. On the basis of experiments, some factors which affect the energy resolution of the system are discussed. The optimum parameters configuration for the system is presented and it provides a decision-making ground for purchasing, installation and alignment of analogous system. (authors)

  14. Gamma-ray impurities of {sup 111}In, {sup 201}Tl, {sup 177}Lu and {sup 99m}Tc determined by means of a HPGE spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Koskinas, Marina F.; Almeida, Jamille da Silveira; Moreira, Denise Simões; Semmler, Renato; Dias, Mauro da Silva, E-mail: koskinas@ipen.br, E-mail: jamillealmeida@gmail.com, E-mail: denise.moreira@ipen.br, E-mail: rsemmler@ipen.br, E-mail: msdias@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-11-01

    This work aims to present the radioactive impurities gamma rays emitters detected in some radiopharmaceuticals widely applied to diagnosis and therapy purposes, supplied to nuclear medicine services in Brazil by the Radiopharmaceutical Center(CR) of Nuclear and Energy Research Institute, IPEN, in São Paulo. The analysis was undertaken by means of an HPGe gamma spectrometer. The radiopharmaceuticals analyzed were: {sup 111}In, {sup 201}Tl, {sup 177}Lu and {sup 99m}Tc. (author)

  15. Determination of 228Th, 226Ra and 40K in Soil Using In-Situ GammaSpectrometer

    International Nuclear Information System (INIS)

    Bunawas; Wahyudi; Syarbaini; Untara

    2000-01-01

    Determination of natural radionuclide in latosol soil at six locationsaround PPTN Serpong by using Inspector portable gamma spectrometer with highpurity Germanium detector (HPGe) which has 26% relative efficiency had beenobtained. Radionuclides data of 228 Th, 226 Ra and 40 K were obtained in4 hours, shorter than laboratories analysis which needed 3 weeks. Thedifferences between in-situ measurement and laboratory were 3.6% to 56.2% forsix conditions of soil measured. According to the specific activity dataanalysis using statistic hypothesis, the result shows that the activity of 228 Th and 226 Ra are independent on location, but 40 K is dependent onlocation. (author)

  16. Ground tests with prototype of CeBr{sub 3} active gamma ray spectrometer proposed for future venus surface missions

    Energy Technology Data Exchange (ETDEWEB)

    Litvak, M.L., E-mail: litvak@mx.iki.rssi.ru [Space Research Institute, RAS, Moscow 117997 (Russian Federation); Sanin, A.B.; Golovin, D.V. [Space Research Institute, RAS, Moscow 117997 (Russian Federation); Jun, I. [Jet Propulsion Laboratory, Pasadena, CA (United States); Mitrofanov, I.G. [Space Research Institute, RAS, Moscow 117997 (Russian Federation); Shvetsov, V.N.; Timoshenko, G.N. [Joint Institute for Nuclear Research, Dubna (Russian Federation); Vostrukhin, A.A. [Space Research Institute, RAS, Moscow 117997 (Russian Federation)

    2017-03-11

    The results of a series of ground tests with a prototype of an active gamma-ray spectrometer based on a new generation of scintillation crystal (CeBr{sub 3}) are presented together with a consideration to its applicability to future Venus landing missions. We evaluated the instrument's capability to distinguish the subsurface elemental composition of primary rock forming elements such as O, Na, Mg, Al, Si, K and Fe. Our study uses heritage from previous ground and field tests and applies to the analysis of gamma lines from activation reaction products generated by a pulsed neutron generator. We have estimated that the expected accuracies achieved in this approach could be as high as 1–10% for the particular chemical element being studied.

  17. A mobile gamma ray spectrometer system for nuclear hazard mapping

    International Nuclear Information System (INIS)

    Smethurst, Mark A.

    2000-12-01

    The Geological Survey of Norway has developed a system for mobile gamma ray spectrometer surveying suitable for use in nuclear emergencies where potentially dangerous radioactive materials have been released into the environment. The measuring system has been designed for use with different kinds of transportation platforms. These include fixed-wing aircraft, helicopters and vans. The choice of transportation platform depends on the nature of the nuclear emergency. Widespread fallout from a distant source can be mapped quickly from the air while local sources of radiation can be delineated by a car-borne system. The measuring system processes gamma ray spectra in real time. The operator of the system is therefore able to guide surveying in accordance with meaningful data values and immediately report these values to decision making authorities. The operator is presented with a number of different displays suited to different kinds of nuclear emergencies that lead to more efficient surveying. Real time processing of data means that the results of a survey can be delivered to decision makers immediately upon return to base. It is also possible to deliver data via a live mobile telephone link while surveying is underway. The measuring system can be adjusted to make measurements lasting between 1 second and 5 seconds. The spatial density of measuring positions depends on the duration of each measurement and the speed of travel of the measuring system. Measuring with 1 s intervals while travelling at 50 km/h in a car results in a measurement every 14 m along the road. Measuring with 1 s intervals in an aeroplane travelling at 250 km/h produces a measurement for every 70 m travelled. Eight hours surveying can produce up to 30000 measurements over a region hundreds of kilometres across. (Author)

  18. A study of radiocaesium concentrations in the Irish marine environment using a high resolution gamma-ray spectrometer

    International Nuclear Information System (INIS)

    Vidal-Quadras, A.; Mitchell, P.I.

    1983-01-01

    A selection of marine samples collected in the vicinity of Dublin Bay on the East Coast of Ireland and Galway Bay on the West Coast have been analyzed with a high resolution Compton suppression spectrometer designed for the analysis of low-level environmental samples. Radiocaesium levels in these samples are compared and some preliminary conclusions presented. The principal components of the spectrometer, which is described in detail, are (I) an upward-locking Ge(Li) detector mounted in a special NPR-type cryostat, (II) active shielding in the form of a well detector fashioned from NE102A scintillator and a NaI(T1) detector, (III) an anti-Compton analyzer and (IV) a multichannel analyzer. The multichannel analyzer is interfaced with a 32K microcomputer to a Digital VAX-11/780 computer where up-to-date gamma spectroscopy techniques are employed for the deconvolution of spectra, search and identification of each line and estimation of the activity of each radionuclide. (author)

  19. Airborne Gamma-ray Measurements in the Chernobyl Plume

    DEFF Research Database (Denmark)

    Grasty, R. L.; Hovgaard, Jens; Multala, J.

    1997-01-01

    On 29 April 1986, the Geological Survey of Finland (GSF) survey aircraft with a gamma ray spectrometer flew through a radioactive plume from the Chernobyl nuclear accident. The aircraft became contaminated and the gamma spectrometer measured radioactivity in the plume as well as radioactivity...

  20. Integration of auto analysis program of gamma spectrum and software and determination of element content in sample by k-zero method

    International Nuclear Information System (INIS)

    Trinh Quang Vinh; Truong Thi Hong Loan; Mai Van Nhon; Huynh Truc Phuong

    2014-01-01

    Integrating the gamma spectrum auto-analysis program with elemental analysis software by k-zero method is the objective for many researchers. This work is the first stepin building an auto analysis program of gamma spectrum, which includes modules of reading spectrum, displaying spectrum, calibrating energy of peak, smoothing spectrum, calculating peak area and determining content of elements in sample. Then, the results from the measurements of standard samples by a low level spectrometer using HPGe detector are compared to those of other gamma spectrum auto-analysis programs. (author)

  1. Fast neutron and gamma-ray spectra measurements with a NE-213 spectrometer in the FNG Copper Benchmark Experiment

    International Nuclear Information System (INIS)

    Klix, Axel; Angelone, Maurizio; Fischer, Ulrich; Pillon, Mario

    2016-01-01

    Highlights: • Fast neutron and gamma-ray spectra were measured in a copper assembly irradiated with DT neutrons. • The results were compared with MCNP calculations. • Primary aim was to provide experimental data for checking and validation of nuclear data evaluations of copper. - Abstract: A neutronics benchmark experiment on a pure Copper assembly was performed at the Frascati Neutron Generator. The work aimed at testing of recent nuclear data libraries. This paper focuses on the measurement of fast neutron and gamma-ray flux spectra in the Copper assembly under DT neutron irradiation in two selected positions with a spectrometer based on the organic liquid scintillator NE-213. The measurement results were compared with Monte Carlo radiation transport calculations using MCNP and nuclear data from the JEFF-3.1.1 library. Calculations have been done with Cu data from JEFF-3.1.1, JEFF-3.2, FENDL-3 and ENDF/B-7.0. Discrepancies appear in the intermediate neutron energy range between experiment and calculation. Large discrepancies were observed in the gamma-ray spectra calculated with JEFF-3.2.

  2. Fast neutron and gamma-ray spectra measurements with a NE-213 spectrometer in the FNG Copper Benchmark Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Klix, Axel, E-mail: axel.klix@kit.edu [Karlsruhe Institute of Technology, Institute for Neutron Physics and Reactor Technology Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Angelone, Maurizio [ENEA Dipartimento Fusione e Tecnologie per la Sicurezza Nucleare, C.R. Frascati, via E. Fermi 45, 00044 Frascati (Italy); Fischer, Ulrich [Karlsruhe Institute of Technology, Institute for Neutron Physics and Reactor Technology Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Pillon, Mario [ENEA Dipartimento Fusione e Tecnologie per la Sicurezza Nucleare, C.R. Frascati, via E. Fermi 45, 00044 Frascati (Italy)

    2016-11-01

    Highlights: • Fast neutron and gamma-ray spectra were measured in a copper assembly irradiated with DT neutrons. • The results were compared with MCNP calculations. • Primary aim was to provide experimental data for checking and validation of nuclear data evaluations of copper. - Abstract: A neutronics benchmark experiment on a pure Copper assembly was performed at the Frascati Neutron Generator. The work aimed at testing of recent nuclear data libraries. This paper focuses on the measurement of fast neutron and gamma-ray flux spectra in the Copper assembly under DT neutron irradiation in two selected positions with a spectrometer based on the organic liquid scintillator NE-213. The measurement results were compared with Monte Carlo radiation transport calculations using MCNP and nuclear data from the JEFF-3.1.1 library. Calculations have been done with Cu data from JEFF-3.1.1, JEFF-3.2, FENDL-3 and ENDF/B-7.0. Discrepancies appear in the intermediate neutron energy range between experiment and calculation. Large discrepancies were observed in the gamma-ray spectra calculated with JEFF-3.2.

  3. A digital multi-channel spectroscopy system with 100 MHz flash ADC module for the GENIUS-TF and GENIUS projects

    OpenAIRE

    Kihm, T.; Bobrakov, V. F.; Klapdor-Kleingrothaus, H. V.

    2003-01-01

    In this paper we will present the first results of applying a digital processing technology in low-level gamma spectroscopy with HPGE detectors. An experimental gamma spectrometer using Flash ADC module is built and tested. The test system is now under development and shows major advantages over the traditional analog technologies. It will be installed for the GENIUS-TF and GENIUS projects in Gran-Sasso in early 2003.

  4. Ultimate detection sensitivity of Ge-Li γ-ray spectrometers

    International Nuclear Information System (INIS)

    1978-06-01

    This paper presents the principal results of a study concerning low-level counting capabilities of GeLi gamma-ray spectrometers. The expression adopted for the theoretical sensitivity limit of gamma spectrometers has been experimentally verified with very low activity samples, using 17 installations of various characteristics. This expression sets off the influence of the efficiency, the environmental conditions on the sensitivity limits. It can be used also to eliminate the fraudulents peaks in automatical analysis of gamma-ray spectras. At last, it provides a list of criteria to determine the most suitable characteristics of a detector according to a special problem. Informations which have to be obtained from the manufacturers are specified [fr

  5. Low background gamma ray spectrometer using the anticoincidence shield technique at KAERI

    International Nuclear Information System (INIS)

    Byun, Jong In; Choi, Yun Ho; Kwak, Seung Im; Hwang, Han Yull; Chung, Kun Ho; Choi, Geun Sik; Park, Doo Won; Lee, Chang Woo

    2002-01-01

    We develop a ultra-low background gamma ray spectrometer, using active and passive shielding technique at the same time. Cosmic ray induced background is suppressed by means of active shield devices consisting of plastic scintillating plates of 50 mm thick and anti-coincidence electronic system. The shield is made of 150 mm thick walls of very low activity lead, especially 20 mm with activity of -1 and 0.36 s -1 with and without active shield, respectively, on the regions from 50 keV to 3 MeV. The detection efficiency curve has been precisely measured for regions from 80 keV to 2 MeV with a 10 3 ml marinelli beaker sample, made with calibrated mixed-sources consists of 109 Cd, 57 Co, 139 Ce, 203 Hg, 113 Sn, 85 Sr, 137 Cs, 60 Co and 88 Y. The virtues of the method are demonstrated by applying on experiment that requires the lowest detection limit

  6. GABAergic modulation of visual gamma and alpha oscillations and its consequences for working memory performance.

    Science.gov (United States)

    Lozano-Soldevilla, Diego; ter Huurne, Niels; Cools, Roshan; Jensen, Ole

    2014-12-15

    Impressive in vitro research in rodents and computational modeling has uncovered the core mechanisms responsible for generating neuronal oscillations. In particular, GABAergic interneurons play a crucial role for synchronizing neural populations. Do these mechanistic principles apply to human oscillations associated with function? To address this, we recorded ongoing brain activity using magnetoencephalography (MEG) in healthy human subjects participating in a double-blind pharmacological study receiving placebo, 0.5 mg and 1.5 mg of lorazepam (LZP; a benzodiazepine upregulating GABAergic conductance). Participants performed a demanding visuospatial working memory (WM) task. We found that occipital gamma power associated with WM recognition increased with LZP dosage. Importantly, the frequency of the gamma activity decreased with dosage, as predicted by models derived from the rat hippocampus. A regionally specific gamma increase correlated with the drug-related performance decrease. Despite the system-wide pharmacological intervention, gamma power drug modulations were specific to visual cortex: sensorimotor gamma power and frequency during button presses remained unaffected. In contrast, occipital alpha power modulations during the delay interval decreased parametrically with drug dosage, predicting performance impairment. Consistent with alpha oscillations reflecting functional inhibition, LZP affected alpha power strongly in early visual regions not required for the task demonstrating a regional specific occipital impairment. GABAergic interneurons are strongly implicated in the generation of gamma and alpha oscillations in human occipital cortex where drug-induced power modulations predicted WM performance. Our findings bring us an important step closer to linking neuronal dynamics to behavior by embracing established animal models. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Coincidence gamma-ray spectrometry

    DEFF Research Database (Denmark)

    Markovic, Nikola; Roos, Per; Nielsen, Sven Poul

    2017-01-01

    Gamma-ray spectrometry with high-purity germanium (HPGe) detectors is often the technique of choice in an environmental radioactivity laboratory. When measuring environmental samples associated activities are usually low so an important parameter that describes the performance of the spectrometer...... for a nuclide of interest is the minimum detectable activity (MDA). There are many ways for lowering the MDAs in gamma spectrometry. Recently, developments of fast and compact digital acquisition systems have led to growing number of multiple HPGe detector spectrometers. In these applications all detected...

  8. The SPEDE electron spectrometer

    CERN Document Server

    O'Neill, George

    This thesis presents SPEDE (SPectrometer for Electron DEtection) and documents its construction, testing and performance during commissioning at Jyvaskyla, Finland, before deployment at the HIE-ISOLDE facility at CERN coupled with the MINIBALL array to perform in-beam electron-gamma spectroscopy using post-accelerated radioactive ion beams. Commissioning experiments took place in two two-day stints during spring 2015, coupled with several JUROGAMII gamma-detectors. This spectrometer will help aid in fully understanding exotic regions of the nuclear chart such as regions with a high degree of octupole deformation, and in those nuclei exhibiting shape coexistence. For the rst time, electron spectroscopy has been performed at the target position from states populated in accelerated nuclei via Coulomb excitation. The FWHM of SPEDE is approximately 7 keV at 320 keV, and Doppler correction was possible to improve Doppler broadened peaks. The results are intended to give the reader a full understanding of the dete...

  9. Design and construction of the 8K multi-channel gamma spectrometer module (ADC+MCD)

    International Nuclear Information System (INIS)

    Vu Xuan Cach; Hoang Thi Ngoc Bich; Truong Van Dat; Pham Ngoc Tuan; Dang Lanh; Tuong Thi Thu Huong; Nguyen Xuan Hai

    2007-01-01

    A multichannel pulse-height analyzer system (MCA) consists of an ADC with 8192 channel performance, a histogramming memory, and a visual display of the histogram, implemented on a Personal Computer (PC). The purpose of the analog-to-digital converter (ADC) is to measure the maximum amplitude of an analog pulse, and convert that value into a digital number. This digital output is a proportional representation of the analog amplitude at the ADC input. The digital ADC outputs are stored in a histogram memory, where each bin represents a pulse height interval and the number of events in each bin represents the number of events in that interval. The combination of ADC, histogramming memory and display functions are the minimum to constitute a multichannel analyzer or MCA based on PC. It is designed and fabricated on a single NIM module. The communication between MCA module and PC implements via USB bus. In our application, performance of the USB standard version 1.1 is good enough for purposes. The application program was designed in LabWIEW 8.0 software. This application is the main display and acquisition software for the MCA module. It is compatible with Windows 98SE/XP. The libraries USB driver, with their supporting files, are in the FTD2XX driver DLL Package and D2XX function 7.0 for LabWIEW supporting. These libraries are used to write custom code to control the MCA module. The 8K MCA module has the main following hardware specifications: ADC Successive-approximation type with sliding scale linearization; resolution: 8192 channels; dead time per event: 5 μs, including memory transfer; integral nonlinearity: ±0.025% over the top 98% of the dynamic range; differential nonlinearity: < ±1% over the top 98% of the dynamic range; data memory: 224 counts per channel (16 millions counts); presets; Real Time/Live Time: 1 to 232(s), Multiples of 1 s; ADC LLD and ULD Aajustable from 0 to 100% of full scale via hardware control; input accepts positive unipolar pulses in

  10. A real-time neutron-gamma discriminator based on the support vector machine method for the time-of-flight neutron spectrometer

    Science.gov (United States)

    Wei, ZHANG; Tongyu, WU; Bowen, ZHENG; Shiping, LI; Yipo, ZHANG; Zejie, YIN

    2018-04-01

    A new neutron-gamma discriminator based on the support vector machine (SVM) method is proposed to improve the performance of the time-of-flight neutron spectrometer. The neutron detector is an EJ-299-33 plastic scintillator with pulse-shape discrimination (PSD) property. The SVM algorithm is implemented in field programmable gate array (FPGA) to carry out the real-time sifting of neutrons in neutron-gamma mixed radiation fields. This study compares the ability of the pulse gradient analysis method and the SVM method. The results show that this SVM discriminator can provide a better discrimination accuracy of 99.1%. The accuracy and performance of the SVM discriminator based on FPGA have been evaluated in the experiments. It can get a figure of merit of 1.30.

  11. Compact terahertz spectrometer based on disordered rough surfaces

    Science.gov (United States)

    Yang, Tao; Jiang, Bing; Ge, Jia-cheng; Zhu, Yong-yuan; Li, Xing-ao; Huang, Wei

    2018-01-01

    In this paper, a compact spectrometer based on disordered rough surfaces for operation in the terahertz band is presented. The proposed spectrometer consists of three components, which are used for dispersion, modulation and detection respectively. The disordered rough surfaces, which are acted as the dispersion component, are modulated by the modulation component. Different scattering intensities are captured by the detection component with different extent of modulation. With a calibration measurement process, one can reconstruct the spectra of the probe terahertz beam by solving a system of simultaneous linear equations. A Tikhonov regularization approach has been implemented to improve the accuracy of the spectral reconstruction. The reported broadband, compact, high-resolution terahertz spectrometer is well suited for portable terahertz spectroscopy applications.

  12. The calibration facilities of gamma-ray spectrometer oil logging system

    International Nuclear Information System (INIS)

    Zhao Yunlong; Liu Yuzhang; Duan Wenxian

    1993-08-01

    The construction technology for the calibration facilities of gamma-ray spectrometer oil logging system is introduced. It is referenced to the experience from similar calibration facilities at home and abroad. Facilities consist of 9 models. The effective diameter of each model is 1.5 m and the height is 6 m. Each borehole has U ore zone, Th ore zone, K ore zone, high mixed zone, high mixed thin zone, low mixed zone and barren zone. There are 45 zones in total. Each element model has 6 in, 8.5 in and 12 in of different diameters. The preventing radon migration and complete sealing technology are used for each zone to prevent radon from escaping. The density of models, homogeneity and moisture of radio elements have been measured that gives a complete data for calibration adjusting of the instrument. The sizes of facilities and the concentration of radioactivity are reasonable designed and conformed to the recommendation of IAEA. Parameters are consistent with the parameters of calibration facilities built by Houston University in America. The emanation coefficient of the facilities is lees than 1%. The dry density of filling is 2.12 g/cm 3 and the relative standard deviation is +- 1.9%

  13. Dosimetry computer module of the gamma irradiator of ININ; Modulo informatico de dosimetria del irradiador gamma del ININ

    Energy Technology Data Exchange (ETDEWEB)

    Ledezma F, L. E.; Baldomero J, R. [ININ, Gerencia de Sistemas Informaticos, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico); Agis E, K. A., E-mail: luis.ledezma@inin.gob.mx [Universidad Autonoma del Estado de Mexico, Facultad de Ingenieria, Cerro de Coatepec s/n, Ciudad Universitaria, 50100 Toluca, Estado de Mexico (Mexico)

    2012-10-15

    This work present the technical specifications for the upgrade of the dosimetry module of the computer system of the gamma irradiator of the Instituto Nacional de Investigaciones Nucleares (ININ) whose result allows the integration and consultation of information in industrial dosimetry subject under an outline client-server. (Author)

  14. Search for Bound $\\overline{N}N$ States Using a Precision Gamma and Charged Pion Spectrometer at LEAR

    CERN Multimedia

    2002-01-01

    This experiment uses a magnetic spectrometer to search for monoenergetic @g and @p@+ transitions between bound N&bar.N states. The spectrometer is instrumented with drift chambers (NDC, RDC and PDC), proportional wire chambers (A-E), and various thin scintillation counters (S,M,G,AH,V,Q,D,E and PH) f purposes, as shown in the accompanying drawing.\\\\ \\\\ Gamma-rays produced in the LH^2 target are materialized by a 10\\% converter located in the B chamber with an acceptance (@D@W/4@p) of @=2-6x10|-|3 (100-400 MeV) and 6x10|-|3 ($>$400 MeV). Trajectories of bent electron-positron pairs and @p@+ are measured in the A-E~chambers. Trajectories of less frequent high energy penetrating tracks, as well as the remaining associated charged annihilation products exiting the target, are measured in the drift chamber system. \\\\ \\\\ The resultant energy resolution (@DE/E) is better than 1,5\\% R.M.S. over the full range of energies studied. To illustrate the sensitivity of this experiment, a @g line at 300 MeV produced at t...

  15. Altered modulation of gamma oscillation frequency by speed of visual motion in children with autism spectrum disorders.

    Science.gov (United States)

    Stroganova, Tatiana A; Butorina, Anna V; Sysoeva, Olga V; Prokofyev, Andrey O; Nikolaeva, Anastasia Yu; Tsetlin, Marina M; Orekhova, Elena V

    2015-01-01

    Recent studies link autism spectrum disorders (ASD) with an altered balance between excitation and inhibition (E/I balance) in cortical networks. The brain oscillations in high gamma-band (50-120 Hz) are sensitive to the E/I balance and may appear useful biomarkers of certain ASD subtypes. The frequency of gamma oscillations is mediated by level of excitation of the fast-spiking inhibitory basket cells recruited by increasing strength of excitatory input. Therefore, the experimental manipulations affecting gamma frequency may throw light on inhibitory networks dysfunction in ASD. Here, we used magnetoencephalography (MEG) to investigate modulation of visual gamma oscillation frequency by speed of drifting annular gratings (1.2, 3.6, 6.0 °/s) in 21 boys with ASD and 26 typically developing boys aged 7-15 years. Multitaper method was used for analysis of spectra of gamma power change upon stimulus presentation and permutation test was applied for statistical comparisons. We also assessed in our participants visual orientation discrimination thresholds, which are thought to depend on excitability of inhibitory networks in the visual cortex. Although frequency of the oscillatory gamma response increased with increasing velocity of visual motion in both groups of participants, the velocity effect was reduced in a substantial proportion of children with ASD. The range of velocity-related gamma frequency modulation correlated inversely with the ability to discriminate oblique line orientation in the ASD group, while no such correlation has been observed in the group of typically developing participants. Our findings suggest that abnormal velocity-related gamma frequency modulation in ASD may constitute a potential biomarker for reduced excitability of fast-spiking inhibitory neurons in a subset of children with ASD.

  16. Improvement and Validation of an Aerosol Deposition Model in the GAMMA-FP, a Fission Product Analysis Module for VHTRs

    International Nuclear Information System (INIS)

    Yoon, Churl; Lim, Hong Sik

    2013-01-01

    GAMMA-FP (GAs Multicomponent Mixture Analysis-Fission Products module), consists of gaseous and aerosol fission product analysis modules. The aerosol FP module adopts a multi-component and multi-sectional aerosol analysis model that has been developed based on the MAEROS model. For the first work of FP module development, the MAEROS model has been implemented and examined against some analytic solutions and experimental data by Yoo et al. An aerosol transport model was developed and implemented in the GAMMA-FP code, and verified. In this study, the aerosol deposition model in the GAMMA-FP code was improved by adopting recent achievements, and was validated against an experimental data available. The aerosol deposition model in the GAMMA-FP code has been improved and successfully validated against the STORM SR-11 deposition test. The simulation with the improved deposition model predicted the matched results with the experimental data well. For future studies, the aerosol deposition model by flow irregularities will be implemented and validated against the TRANSAT bend effect test

  17. Improvement and Validation of an Aerosol Deposition Model in the GAMMA-FP, a Fission Product Analysis Module for VHTRs

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Churl; Lim, Hong Sik [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-10-15

    GAMMA-FP (GAs Multicomponent Mixture Analysis-Fission Products module), consists of gaseous and aerosol fission product analysis modules. The aerosol FP module adopts a multi-component and multi-sectional aerosol analysis model that has been developed based on the MAEROS model. For the first work of FP module development, the MAEROS model has been implemented and examined against some analytic solutions and experimental data by Yoo et al. An aerosol transport model was developed and implemented in the GAMMA-FP code, and verified. In this study, the aerosol deposition model in the GAMMA-FP code was improved by adopting recent achievements, and was validated against an experimental data available. The aerosol deposition model in the GAMMA-FP code has been improved and successfully validated against the STORM SR-11 deposition test. The simulation with the improved deposition model predicted the matched results with the experimental data well. For future studies, the aerosol deposition model by flow irregularities will be implemented and validated against the TRANSAT bend effect test.

  18. A novel approach for predicting the response of the spectrometer for INTEGRAL satellite.

    Science.gov (United States)

    Kshetri, R

    2013-05-01

    A basic phenomenological approach has been presented in three recent papers (Kshetri R., 2012. JINST 7, P04008; Kshetri R., 2012. JINST 7, P07006; Kshetri R., 2012. JINST 7, P12007) for understanding the operation of encapsulated type composite detectors including the SPI spectrometer. In the present paper, we have considered the fact that the experimental two-fold events between two detectors include the three and higher fold events between the same two detectors. The formalism has been further developed and the peak-to-total ratio of a general composite detector are predicted for energy region with no direct experimental information about them. At 8MeV, the peak-to-total ratio for the SPI spectrometer and a very large detector (comprising of infinite number of single HPGe modules) are found to be 9% and 12%, respectively. The predictions for fold distribution of the SPI spectrometer are found to be in agreement with experimental data. Our formulation does not include ad-hoc fits, but expressions that are justifiable by probability flow arguments. Instead of using an empirical method or simulation, we present a novel approach for calculating the peak-to-total ratio of the SPI spectrometer for high gamma energies. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. A neutron spectrometer based on the combination of time-of-flight and Larmor modulation

    International Nuclear Information System (INIS)

    Mulder, F.M.; Kreuger, R.; Grigoriev, S.V.; Kraan, W.H.; Rekveldt, M.Th.; Van Well, A.A.

    1999-01-01

    A study on the feasibility of neutron beam instrumentation that applies Larmor modulation for incoming, and time-of-flight for scattered wavelength determination (or vice versa) is currently under way at IRI. The instrument resulting from this combination can in principle measure quasi elastic and inelastic scattering with a flexible resolution and dynamic range. An important difference with current spectrometers is that there is no selection of neutron wavelengths for either the incoming beam (direct geometry) or scattered beam (inverted geometry). Therefore much of the available flux is used and there is no a priory selection of the energy transfer range and resolution. This instrument will be mainly applicable for quasi-elastic scattering and complex line shapes that are extended over a broad range in energy transfer. Line shapes can be measured directly in Fourier space, which is often advantageous. Due to signal to noise considerations, this instrument will be less suitable for the determination of weak, discrete energy transfer signals. A requirement for the Larmor modulator is that it can work with a white neutron beam. This can be realised for neutrons having a wavelength above ∼ 0.1 nm by use of 'adiabatic resonance π flippers'. This type of instrument may be applied at the future ESS pulsed neutron source in order to complement current spectrometers. (author)

  20. EE's gamma-ray spectrometer answers the national need for a portable, rugged, self-contained radioisotope analyzer

    International Nuclear Information System (INIS)

    McGibbon, A.L.

    1976-01-01

    Growing national interest in public safety has produced a sudden need for a type of radiation-monitoring equipment that doesn't exist anywhere commercially. An easily portable, very rugged, and completely self-contained instrument is required that can be set up quickly and virtually anywhere to detect and identify radioactive isotopes. The Electronics Engineering Department has responded to this need by designing and developing the first equipment that can fulfill all these requirements. This instrument, a 1024-channel gamma-ray spectrometer, has already gone into limited production to provide health physicists at LLL and other Energy Research and Development Administration (ERDA) laboratories with an effective tool for monitoring possible sources of radioactivity

  1. Measuring the energies and multiplicities of prompt gamma-ray emissions from neutron-induced fission of $^{235}$U using the STEFF spectrometer

    CERN Document Server

    AUTHOR|(CDS)2093036; Smith, Alastair Gavin; Wright, Tobias James

    Following a NEA high priority nuclear data request, an experimental campaign to measure the prompt $\\gamma$-ray emissions from $^{235}$U has been performed. This has used the STEFF spectrometer at the new Experimental Area 2 (EAR2) within the neutron timeof-flight facility (n_TOF), a white neutron source facility at CERN with energies from thermal to approximately 1 GeV. Prior to the experimental campaign, STEFF has been optimised for the environment of EAR2. The experimental hall features a high background $\\gamma$-ray rate, due to the nature of the spallation neutron source. Thus an investigation into reduction of the background $\\gamma$-ray rate, encountered by the NaI(Tl) detector array of STEFF, has been carried out. This has been via simulations using the simulation package FLUKA. Various materials and shielding geometries have been investigated but the effects determined to be insufficient in reducing the background rate by a meaningful amount. The NaI(Tl) detectors have been modified to improve their ...

  2. Airborne gamma-ray spectrometer and magnetometer survey Coos Bay, Oregon. Final report

    International Nuclear Information System (INIS)

    1981-05-01

    During the months of August, September, and October of 1980, Aero Service Division Western Geophysical Company of America conducted an airborne high sensitivity gamma-ray spectrometer and magnetometer survey over ten (10) areas over northern California and southwestern Oregon. These include the 2 0 x 1 0 NTMS quadrangles of Roseburg, Medford, Weed, Alturas, Redding, Susanville, Ukiah, and Chico along with the 1 0 x 2 0 areas of the Coos Bay quadrangle and the Crescent City/Eureka areas combined. This report discusses the results obtained over the Coos Bay, Oregon, map area. Line spacing was generally six miles for east/west traverses and eighteen miles for north/south tie lines over the northern one-half of the area. Traverses and tie lines were flown at three miles and twelve miles respectively over the southern one-half of the area. A total of 16,880.5 line miles of geophysical data were acquired, compiled, and interpreted during the survey, of which 863.8 line miles are in this quadrangle

  3. Airborne gamma-ray spectrometer and magnetometer survey: Alturas quadrangle, California. Final report

    International Nuclear Information System (INIS)

    1981-05-01

    An airborne high sensitivity gamma-ray spectrometer and magnetometer survey was conducted over ten (10) areas over northern California and southwestern Oregon. These include the 2 0 x 1 0 NTMS quadrangles of Roseburg, Medford, Weed, Alturas, Redding, Susanville, Ukiah, and Chico along with the 1 0 x 2 0 areas of the Coos Bay quadrangle and the Crescent City/Eureka areas combined. This report discusses the results obtained over the Alturas, California, map area. Traverse lines were flown in an east-west direction at a line spacing of six (6) miles. Tie lines were flown north-south approximately eighteen (18) miles apart. A total of 16,880.5 line miles of geophysical data were acquired, compiled, and interpreted during the survey, of which 1631.6 line miles are in this quadrangle. The purpose of this study is to acquire and compile geologic and other information with which to assess the magnitude and distribution of uranium resources and to determine areas favorable for the occurrence of uranium in the United States

  4. Airborne gamma-ray spectrometer and magnetometer survey: Susanville quadrangle, California. Final report

    International Nuclear Information System (INIS)

    1981-05-01

    An airborne high sensitivity gamma-ray spectrometer and magnetometer survey was conducted over ten (10) areas over northern California and southwestern Oregon. These include the 2 0 x 1 0 NTMS quadrangles of Roseburg, Medford, Weed, Alturas, Redding, Susanville, Ukiah, and Chico along with the 1 0 x 2 0 areas of the Coos Bay quadrangle and the Crescent City/Eureka areas combined. This report discusses the results obtained over the Susanville, California, map area. Traverse lines were flown in an east-west direction at a line spacing of six (6) miles. Tie lines were flown north-south approximately eighteen (18) miles apart. A total of 16,880.5 line miles of geophysical data were acquired, compiled, and interpreted during the survey, of which 1642.8 line miles are in this quadrangle. The purpose of this study is to acquire and compile geologic and other information with which to assess the magnitude and distribution of uranium resources and to determine areas favorable for the occurrence of uranium in the United States

  5. Investigation of Soft Photon Production in Hadronic Collisions Using the OMEGA Spectrometer

    CERN Multimedia

    2002-01-01

    The Omega Spectrometer, with a hydrogen target and two electromagnetic calorimeters, is used to investigate the anomalous production of soft $\\gamma$s in hadronic collisions. The experiment is aimed at confirming an observation made in BEBC: the yield of soft $\\gamma$s (70\\% of the $\\gamma$s have c.m. energies in the range (20~$<$~E(@g)~$<$~60~MeV)) exceeds the QED prediction of hadronic bremsstrahlung by a factor of 3. This effect may be related to the anomalous production of low mass lepton pairs (virtual $\\gamma$s) observed in several hadronic experiments. \\\\ \\\\ An interaction trigger is used to collect events of @p@+p collisions (and pp tagged by Cedars in the beam) at 280~GeV/c. The charged tracks are recorded by the @W spectrometer, the @g's in the two calorimeters. The @g's arising from hadronic radiative decay (mostly @p|0's) are reconstructed, and subtracted event by event. The remaining @g spectrum is studied, in a region of phase space where the background (e.g. bachelor @g's from uncompletel...

  6. Efficiency-optimized low-cost TDPAC spectrometer using a versatile routing/coincidence unit

    Energy Technology Data Exchange (ETDEWEB)

    Renteria, M., E-mail: renteria@fisica.unlp.edu.ar; Bibiloni, A. G.; Darriba, G. N.; Errico, L. A.; Munoz, E. L.; Richard, D.; Runco, J. [Universidad Nacional de La Plata, Departamento de Fisica, Facultad de Ciencias Exactas (Argentina)

    2008-01-15

    A highly efficient, reliable, and low-cost {gamma}-{gamma} TDPAC spectrometer, PACAr, optimized for {sup 181}Hf-implanted low-activity samples, is presented. A versatile EPROM-based routing/coincidence unit was developed and implemented to be use with the memory-card-based multichannel analyzer hosted in a personal computer. The excellent energy resolution and very good overall resolution and efficiency of PACAr are analyzed and compare with advanced and already tested fast-fast and slow-fast PAC spectrometers.

  7. A mobile device-based imaging spectrometer for environmental monitoring by attaching a lightweight small module to a commercial digital camera.

    Science.gov (United States)

    Cai, Fuhong; Lu, Wen; Shi, Wuxiong; He, Sailing

    2017-11-15

    Spatially-explicit data are essential for remote sensing of ecological phenomena. Lately, recent innovations in mobile device platforms have led to an upsurge in on-site rapid detection. For instance, CMOS chips in smart phones and digital cameras serve as excellent sensors for scientific research. In this paper, a mobile device-based imaging spectrometer module (weighing about 99 g) is developed and equipped on a Single Lens Reflex camera. Utilizing this lightweight module, as well as commonly used photographic equipment, we demonstrate its utility through a series of on-site multispectral imaging, including ocean (or lake) water-color sensing and plant reflectance measurement. Based on the experiments we obtain 3D spectral image cubes, which can be further analyzed for environmental monitoring. Moreover, our system can be applied to many kinds of cameras, e.g., aerial camera and underwater camera. Therefore, any camera can be upgraded to an imaging spectrometer with the help of our miniaturized module. We believe it has the potential to become a versatile tool for on-site investigation into many applications.

  8. GeMini: The Next-Generation Mechanically-Cooled Germanium Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Burks, M

    2008-11-12

    The next-generation mechanically-cooled germanium spectrometer has been developed. GeMini (MINIature GErmanium spectrometer) has been designed to bring high-resolution gamma-ray spectroscopy to a range of demanding field environments. Intended applications include short-notice inspections, border patrol, port monitoring and emergency response, where positive nuclide identification of radioactive materials is required but power and liquid cryogen are not easily available. GeMini weighs 2.75 kg for the basic instrument and 4.5 kg for the full instrument including user interface and ruggedized hermetic packaging. It is very low power allowing it to operate for 10 hours on a single set of rechargeable batteries. This instrument employs technology adapted from the gamma-ray spectrometer currently flying on NASA's Mercury MESSENGER spacecraft. Specifically, infrared shielding techniques allow for a vast reduction of thermal load. This in turn allows for a smaller, lighter-weight design, well-suited for a hand-held instrument. Three working prototypes have been built and tested in the lab. The measured energy resolution is 3 keV fwhm at 662 keV gamma-rays. This paper will focus on the design and performance of the instrument.

  9. Minimum detectable activities for natural radionuclides for IRIS-XP airborne gamma-spectrometer

    International Nuclear Information System (INIS)

    Ohera, Marcel; Sladek, Petr

    2009-01-01

    To subtract the 90 Sr background in the helicopter (the 90 Sr source is used as a freezing deposit indicator in Mi-17 helicopters), a spectrum at the altitude of more than 500 metre altitude above the ground for 10 minutes was acquired. The spectra at 50, 100 and 150 m altitude were corrected for the aircraft and the cosmics, stripping and height attenuation in K, U and Th peak windows. For IRIS-XP, better results have been obtained than presented so far. The new calculated minimum detectable activities (MDAs) are 114 Bq/kg for 40 K, 16 Bq/kg for 238 U and 8 Bq/kg for 232 Th at 95% confidence interval for 1 second spectra at 100 m altitude. This work deals with counting statistics and the estimate of the MDAs for natural radionuclides for the IRIS-XP airborne gamma-ray spectrometer (4 x 4 litre NaI(Tl)) produced by PICO Envirotec, Inc. in Toronto, Canada. The detection sensitivities (MDA) for 4 x 4 NaI(Tl) crystals at the altitude of 90 m presented by Pico Envirotec, Inc. are too high compared with the detection sensitivities presented by other airborne gamma-ray spectrometer producers. This was the reason why to calculate and verify the MDA for IRIS-XP. Firstly, the minimum detectable activities for IRIS-XP for 4 x 4 litre NaI(Tl) crystals were determined based on the data acquired on the calibration pads at the Holland Landing Airport in Toronto, Canada to test the method of calculation used. This method on calibration pads provides all available window sensitivities, stripping factors and counts in the natural radionuclide windows to verify the computing method. Secondly, the MDAs under the real flight conditions were also estimated for the IRIS-XP (4 x 4 litre NaI(Tl) crystals) which was delivered to the Czech Armed Forces. The MDAs were calculated based on the data acquired during the tests at the Military Training Area in Vyskov, Czech Republic. The data was collected at three different altitudes (50 m, 100 m and 150 m) when the Mi-17 helicopter with IRIS

  10. Monte Carlo simulation of muon-induced background of an anti-Compton gamma-ray spectrometer placed in a surface and underground laboratory

    CERN Document Server

    Vojtyla, P

    2005-01-01

    Simulations of cosmic ray muon induced background of an HPGe detector placed inside an anti-Compton shield on the surface and in shallow underground is described. Investigation of several model set-ups revealed some trends useful for design of low-level gamma-ray spectrometers. It has been found that background spectrum of an HPGe detector can be scaled down with the shielding depth. No important difference is observed when the same set-up of the anti-Compton spectrometer is positioned horizontally or vertically. A cosmic-muon rejection factor of at least 40 (at around 1 MeV) can be reached when the anti-Compton suppression is operational. The cosmicmuon background can be reduced to such a level that other background components prevail, like those from the residual contamination of the detector and shield materials and/or from radon, especially for the underground facilities.

  11. New imaging spectrometer CdTe very high spatial and spectral resolution for X and gamma astronomy

    International Nuclear Information System (INIS)

    Dubos, Sebastien

    2015-01-01

    The thesis work presented in this manuscript corresponds to the first development phase of the MC2 project, an ambitious R and D effort to realize a new type of cadmium telluride (CdTe) -based imaging spectrometer for future hard X- and gamma-rays astronomy missions. The final goal is to achieve a 300 micron-pitch pixelated detector plane hybridized with a very low noise front-end electronics for a total pixel density multiplied by 4 compared to the most advanced System recently available in the laboratory, the Caliste HD imaging spectrometer. Moreover, thanks to the joint development of readout circuits adapted to the interconnection of pixelated detectors with low capacitance and low leakage current, spectroscopic performances of such system are assumed to approach inherent limitations of the CdTe detector, especially for the lowest energies. The work was organized in parallel and complementary areas: evaluation of current Systems, feedback and identification of issues associated with the development of highly-resolved detection planes, implementation and complete characterization of a new two-dimensional ASIC specifically developed for this application, and modeling and study of the associated sensor to optimize the design of the detector pattern. Finally, a first hybrid prototype was completed and first experimental tests thereby conducted. (author) [fr

  12. Performance and robustness of a multi-user, multi-spectrometer system for INAA

    International Nuclear Information System (INIS)

    Peter Bode; Menno Blaauw

    2012-01-01

    The laboratory for instrumental neutron activation analysis at the Reactor Institute Delft, Delft University of Technology uses a network of 3 gamma-ray spectrometers with well-type detectors and 2 gamma-ray spectrometers with coaxial detectors, all equipped with modern sample changers, as well as 2 spectrometers with coaxial detectors at the two fast rabbit systems. A wide variety of samples is processed through the system, all at specific optimized (and thus different) analytical protocols, and using different combination of the spectrometer systems. The gamma-ray spectra are analyzed by several qualified operators. The laboratory therefore needs to anticipate on the occurrence of random and systematic inconsistencies in the results (such as bias, non-linearity or wrong assignments due to spectral interferences) resulting from differences in operator performance, selection of analytical protocol and experimental conditions. This has been accomplished by taking advantage of the systematic processing of internal quality control samples such as certified reference materials and blanks in each test run. The data from these internal quality control analyses have been stored in a databank since 1991, and are now used to assess the various method performance indicators as indicators for the method's robustness. (author)

  13. Design And Construction Of The 8K Multi-Channel GAMMA Spectrometer Module (AMPLIFIER+ADC+MCD)

    International Nuclear Information System (INIS)

    Truong Van Dat; Hoang Thi Ngoc Bich; Pham Ngoc Tuan; Dang Lanh; Tuong Thi Thu Huong; Vu Xuan Cach

    2007-01-01

    A multichannel pulse-height analyzer system (MCA) consists of an spectroscopy Amplifier, ADC with 8192 channel performance, a histogramming memory, and a visual display of the histogram implemented on a Personal Computer (PC). The purpose of the analog-to-digital converter (ADC) is to measure the maximum amplitude of an analog pulse, and convert that value into a digital number. This digital output is a proportional representation of the analog amplitude at the ADC input. The digital ADC outputs are stored in a histogram memory, where each bin represents a pulse height interval and the number of events in each bin represents the number of events in that interval. The combination of ADC, histogramming memory and display functions are the minimum to constitute a multichannel analyzer or MCA based on PC. It is designed and fabricated on a single NIM module. The communication between MCA module and PC implements via USB bus. In our application, performance of the USB standard version 1.1 is good enough for purposes. The application program was designed in LabWIEW 8.0 software. This application is the main display and acquisition software for the MCA module. It is compatible with Windows 98SE/XP. The libraries USB driver, with their supporting files, are in the FTD2XX driver DLL Package and D2XX function 7.0 for LabWIEW supporting. These libraries are used to write custom code to control the MCA module. (author)

  14. Final report of the environmental measurement-while-drilling-gamma ray spectrometer system technology demonstration at the Savannah River Site F-Area Retention Basin

    Energy Technology Data Exchange (ETDEWEB)

    Lockwood, G.J.; Normann, R.A.; Williams, C.V.

    1997-08-01

    The environmental measurement-while-drilling-gamma ray spectrometer (EMWD-GRS) system represents an innovative blend of new and existing technology that provides real-time environmental and drill bit data during drilling operations. The EMWD-GRS technology was demonstrated at Savannah River Site F-Area Retention Basin. The EMWD-GRS technology demonstration consisted of continuously monitoring for gamma-radiation-producing contamination while drilling two horizontal boreholes below the backfilled retention basin. These boreholes passed near previously sampled vertical borehole locations where concentrations of contaminant levels of cesium had been measured. Contaminant levels continuously recorded by the EMWD-GRs system during drilling are compared to contaminant levels previously determined through quantitative laboratory analysis of soil samples.

  15. Final report of the environmental measurement-while-drilling-gamma ray spectrometer system technology demonstration at the Savannah River Site F-Area Retention Basin

    International Nuclear Information System (INIS)

    Lockwood, G.J.; Normann, R.A.; Williams, C.V.

    1997-08-01

    The environmental measurement-while-drilling-gamma ray spectrometer (EMWD-GRS) system represents an innovative blend of new and existing technology that provides real-time environmental and drill bit data during drilling operations. The EMWD-GRS technology was demonstrated at Savannah River Site F-Area Retention Basin. The EMWD-GRS technology demonstration consisted of continuously monitoring for gamma-radiation-producing contamination while drilling two horizontal boreholes below the backfilled retention basin. These boreholes passed near previously sampled vertical borehole locations where concentrations of contaminant levels of cesium had been measured. Contaminant levels continuously recorded by the EMWD-GRs system during drilling are compared to contaminant levels previously determined through quantitative laboratory analysis of soil samples

  16. Gamma spectrum measurement in a swimming-pool-type reactor

    International Nuclear Information System (INIS)

    Pla, E.

    1969-01-01

    After recalling the various modes of interaction of gamma rays with matter, the authors describe the design of a spectrometer for gamma energies of between 0.3 and 10 MeV. This spectrometer makes use of the Compton and pair-production effects without eliminating them. The collimator, the crystals and the electronics have been studied in detail and are described in their final form. The problem of calibrating the apparatus is then considered ; numerous graphs are given. The sensitivity of the spectrometer for different energies is determined mainly for the 'Compton effect' group. Finally, in the last part of the report, are given results of an experimental measurement of the gamma spectrum of a swimming-pool type reactor with new elements. (author) [fr

  17. Gamma spectrum measurement in a swimming-pool-type reactor; Mesure du spectre {gamma} d'une pile piscine

    Energy Technology Data Exchange (ETDEWEB)

    Pla, E [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1969-07-01

    After recalling the various modes of interaction of gamma rays with matter, the authors describe the design of a spectrometer for gamma energies of between 0.3 and 10 MeV. This spectrometer makes use of the Compton and pair-production effects without eliminating them. The collimator, the crystals and the electronics have been studied in detail and are described in their final form. The problem of calibrating the apparatus is then considered ; numerous graphs are given. The sensitivity of the spectrometer for different energies is determined mainly for the 'Compton effect' group. Finally, in the last part of the report, are given results of an experimental measurement of the gamma spectrum of a swimming-pool type reactor with new elements. (author) [French] Apres un rappel des differents modes d'interaction des rayons gamma avec la matiere, nous decrivons la conception d'un spectrometre pour les energies gamma s'etendant de 0,3 a 10 MeV. Ce spectrometre utilise les effets Compton et creation de paires sans les eliminer. Le collimateur, les cristaux et l'electronique sont entierement etudies et decrits dans leur realisation definitive. Ensuite, le probleme de l'etalonnage de l'appareil est envisage; de nombreuses courbes sont donnees. La sensibilite du spectrometre pour les differentes energies est determinee principalement pour le groupe ''effet Compton''. Enfin, les resultats d'une experience de mesure du spectre gamma d'une pile piscine avec elements neufs sont donnes dans la derniere partie. (auteur)

  18. Frontal eye fields control attentional modulation of alpha and gamma oscillations in contralateral occipitoparietal cortex.

    Science.gov (United States)

    Marshall, Tom R; O'Shea, Jacinta; Jensen, Ole; Bergmann, Til O

    2015-01-28

    Covertly directing visuospatial attention produces a frequency-specific modulation of neuronal oscillations in occipital and parietal cortices: anticipatory alpha (8-12 Hz) power decreases contralateral and increases ipsilateral to attention, whereas stimulus-induced gamma (>40 Hz) power is boosted contralaterally and attenuated ipsilaterally. These modulations must be under top-down control; however, the control mechanisms are not yet fully understood. Here we investigated the causal contribution of the human frontal eye field (FEF) by combining repetitive transcranial magnetic stimulation (TMS) with subsequent magnetoencephalography. Following inhibitory theta burst stimulation to the left FEF, right FEF, or vertex, participants performed a visual discrimination task requiring covert attention to either visual hemifield. Both left and right FEF TMS caused marked attenuation of alpha modulation in the occipitoparietal cortex. Notably, alpha modulation was consistently reduced in the hemisphere contralateral to stimulation, leaving the ipsilateral hemisphere relatively unaffected. Additionally, right FEF TMS enhanced gamma modulation in left visual cortex. Behaviorally, TMS caused a relative slowing of response times to targets contralateral to stimulation during the early task period. Our results suggest that left and right FEF are causally involved in the attentional top-down control of anticipatory alpha power in the contralateral visual system, whereas a right-hemispheric dominance seems to exist for control of stimulus-induced gamma power. These findings contrast the assumption of primarily intrahemispheric connectivity between FEF and parietal cortex, emphasizing the relevance of interhemispheric interactions. The contralaterality of effects may result from a transient functional reorganization of the dorsal attention network after inhibition of either FEF. Copyright © 2015 the authors 0270-6474/15/351638-10$15.00/0.

  19. The life and death of massive stars revealed by the observation of nuclear gamma-ray lines with the Integral/SPI spectrometer

    International Nuclear Information System (INIS)

    Martin, P.

    2008-11-01

    The aim of this research thesis is to bring up observational constraints on the mechanisms which govern life and death of massive stars, i.e. stars having an initial mass greater than eight times the Sun's mass, and smaller than 120 to 150 solar masses. Thus, it aims at detecting the vestiges of recent and close supernovae in order to find out the traces of the dynamics of their first instants. The author has explored the radiation of three radio-isotopes accessible to the nuclear gamma astronomy ( 44 Ti, 60 Fe, 26 Al) using observations performed with high resolution gamma spectrometer (SPI) on the INTEGRAL international observatory. After an overview of the present knowledge on the massive star explosion mechanism, the author presents the specificities and potential of the investigated radio-isotopes. He describes the data treatment methods and a population synthesis programme for the prediction of decay gamma streaks, and then reports its work on the inner dynamics of Cassiopeia A explosion, the stellar activity of the galaxy revealed by the radioisotope observation, the nucleo-synthetic activity of the Swan region

  20. Digital positron annihilation spectrometer

    International Nuclear Information System (INIS)

    Cheng Bin; Weng Huimin; Han Rongdian; Ye Bangjiao

    2010-01-01

    With the high speed development of digital signal process, the technique of the digitization and processing of signals was applied in the domain of a broad class of nuclear technique. The development of digital positron lifetime spectrometer (DPLS) is more promising than the conventional positron lifetime spectrometer equipped with nuclear instrument modules. And digital lifetime spectrometer has many advantages, such as low noise, long term stability, flexible online or offline digital processing, simple setup, low expense, easy to setting, and more physical information. Digital constant fraction discrimination is for timing. And a new method of optimizing energy windows setting for digital positron lifetime spectrometer is also developed employing the simulated annealing for the convenient use. The time resolution is 220ps and the count rate is 200cps. (authors)

  1. Complete system for portable gamma spectroscopy

    International Nuclear Information System (INIS)

    Fuess, D.A.

    1978-01-01

    The report described a system built around the Computing Gamma Spectrometer (PSA) LEA 74-008. The software primarily supports high-resolution gamma-ray spectroscopy using either a high-purity intrinsic germanium detector (HPGe) or a lithium-drifted germanium detector [Ge(Li)

  2. Nitric oxide isotopic analyzer based on a compact dual-modulation Faraday rotation spectrometer.

    Science.gov (United States)

    Zhang, Eric; Huang, Stacey; Ji, Qixing; Silvernagel, Michael; Wang, Yin; Ward, Bess; Sigman, Daniel; Wysocki, Gerard

    2015-10-14

    We have developed a transportable spectroscopic nitrogen isotopic analyzer. The spectrometer is based on dual-modulation Faraday rotation spectroscopy of nitric oxide isotopologues with near shot-noise limited performance and baseline-free operation. Noise analysis indicates minor isotope ((15)NO) detection sensitivity of 0.36 ppbv·Hz(-1/2), corresponding to noise-equivalent Faraday rotation angle (NEA) of 1.31 × 10(-8) rad·Hz(-1/2) and noise-equivalent absorbance (αL)min of 6.27 × 10(-8) Hz(-1/2). White-noise limited performance at 2.8× the shot-noise limit is observed up to ~1000 s, allowing reliable calibration and sample measurement within the drift-free interval of the spectrometer. Integration with wet-chemistry based on acidic vanadium(III) enables conversion of aqueous nitrate/nitrite samples to gaseous NO for total nitrogen isotope analysis. Isotopic ratiometry is accomplished via time-multiplexed measurements of two NO isotope transitions. For 5 μmol potassium nitrate samples, the instrument consistently yields ratiometric precision below 0.3‰, thus demonstrating potential as an in situ diagnostic tool for environmental nitrogen cycle studies.

  3. Effect of jitter on an imaging FTIR spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Bennett, C. L., LLNL

    1997-04-01

    Line of sight (LOS) jitter produces temporal modulations of the signals which are detected in the focal plane of a temporally modulated imaging Fourier Transform Spectrometer. A theoretical treatment of LOS jitter effects is given, and is compared with the results of measurements with LIFTIRS1 (the Livermore Imaging Fourier Transform InfraRed Spectrometer). The identification, isolation, quantification and removal of jitter artifacts in hyperspectral imaging data by means of principal components analysis is discussed. The theoretical distribution of eigenvalues expected from principal components analysis is used to determine the level of significance of spatially coherent instrumental artifacts in general, including jitter as a representative example. It is concluded that an imaging FTIR spectrometer is much less seriously impacted by a given LOS jitter level than a non imaging FTIR spectrometer.

  4. Radioactivity Monitoring System for TRIGA 2000 Reactor Water Tank with On-Line Gamma Spectrometer

    International Nuclear Information System (INIS)

    Prasetyo Basuki; Sudjatmi KA

    2009-01-01

    One of the requirements in radiological safety in the operating condition of research reactor are the absence of radionuclide from fission product released to reactor cooling water and environment. Early detection of fission product that released from fuel element can be done by monitoring radioactivity level on primary cooling water.Reactor cooling water can be used as an important indicator in detecting radioactivity level of material fission product, when the leakage occurs. Therefore, it needs to build a monitoring system for measuring radioactivity level of cooling water directly and simple. The idea of this system is counting radioactivity water flow from reactor tank to the marinelli cube that attached to the HPGe detector on gamma spectrometer. Cooling water from tank aimed on plastic pipe to the marinelli cube. Water flows in gravitational driven to the marinelli cube, with volume flow rate 5.1 liters/minute in the inlet and 2.2 liters/minute in output. (author)

  5. Bidirectional modulation of hippocampal gamma (20-80 Hz) frequency activity in vitro via alpha(α)- and beta(β)-adrenergic receptors (AR).

    Science.gov (United States)

    Haggerty, D C; Glykos, V; Adams, N E; Lebeau, F E N

    2013-12-03

    Noradrenaline (NA) in the hippocampus plays an important role in memory function and has been shown to modulate different forms of synaptic plasticity. Oscillations in the gamma frequency (20-80 Hz) band in the hippocampus have also been proposed to play an important role in memory functions and, evidence from both in vitro and in vivo studies, has suggested this activity can be modulated by NA. However, the role of different NA receptor subtypes in the modulation of gamma frequency activity has not been fully elucidated. We have found that NA (30 μM) exerts a bidirectional control on the magnitude of kainate-evoked (50-200 nM) gamma frequency oscillations in the cornu Ammonis (CA3) region of the rat hippocampus in vitro via activation of different receptor subtypes. Activation of alpha-adrenergic receptors (α-AR) reduced the power of the gamma frequency oscillation. In contrast, activation of beta-adrenergic receptors (β-AR) caused an increase in the power of the gamma frequency oscillations. Using specific agonists and antagonists of AR receptor subtypes we demonstrated that these effects are mediated specifically via α1A-AR and β1-AR subtypes. NA activated both receptor subtypes, but the α1A-AR-mediated effect predominated, resulting in a reversible suppression of gamma frequency activity. These results suggest that NA is able to differentially modulate on-going gamma frequency oscillatory activity that could result in either increased or decreased information flow through the hippocampus. Copyright © 2013 IBRO. Published by Elsevier Ltd. All rights reserved.

  6. Airborne gamma-ray spectrometer and magnetometer survey, Mitchell Quadrangle, South Dakota. Final report

    International Nuclear Information System (INIS)

    1981-04-01

    An airborne high sensitivity gamma-ray spectrometer and magnetometer survey was conducted over eleven (11) 2 0 x 1 0 NTMS quadrangles located in the states of Minnesota and Wisconsin and seven (7) 2 0 x 1 0 NTMS quadrangles in North and South Dakota. The quadrangles located within the North and South Dakota survey area include Devil's Lake, New Rockford, Jamestown, Aberdeen, Huron, Mitchell, and Sioux Falls. This report discusses the results obtained over the Mitchell map area. The purpose of this program is to acquire and compile geologic and other information with which to assess the magnitude and distribution of uranium resources and to determine areas favorable for the occurrence of uranium in the United States. Traverse lines were flown in an east-west direction at a line spacing of six (6) miles. Tie lines were flown north-south approximately twenty-four (24) miles apart. A total of 21,481 line miles of geophysical data were acquired, compiled, and interpreted during the survey, of which 1479 line miles are in this quadrangle

  7. Airborne gamma-ray spectrometer and magnetometer survey: Huron quadrangle, South Dakota. Final report

    International Nuclear Information System (INIS)

    1981-04-01

    An airborne high sensitivity gamma-ray spectrometer and magnetometer survey was conducted over eleven (11) 2 0 x 1 0 NTMS quadrangles located in the states of Minnesota and Wisconsin and seven (7) 2 0 x 1 0 NTMS quadrangles in North and South Dakota. The quadrangles located within the North and South Dakota survey area include Devil's Lake, New Rockford, Jamestown, Aberdeen, Huron, Mitchell, and Sioux Falls. This report discusses the results obtained over the Huron map area. Traverse lines were flown in an east-west direction at a line spacing of six (6) miles. Tie lines were flown north-south approximately twenty-four (24) miles apart. A total of 21,481 line miles of geophysical data were acquired, compiled, and interpreted during the survey, of which 1459 line miles are in this quadrangle. The purpose of this study is to acquire and compile geologic and other information with which to assess the magnitude and distribution of uranium resources and to determine areas favorable for the occurrence of uranium in the United States

  8. Setup of Mössbauer spectrometers at RCPTM

    Science.gov (United States)

    Pechoušek, J.; Jančík, D.; Frydrych, J.; Navařík, J.; Novák, P.

    2012-10-01

    Setup of Mössbauer spectrometers (MS) for structural, phase, and magnetic characterization of iron-or tin-containing samples is presented. This comprehensive line of 57Fe and 119Sn Mössbauer spectrometers covers transmission spectrometers (TMS) for roomtemperature (RT) measurements, temperature dependent measurements and measurements in an external magnetic field. An RT Conversion Electron/Conversion X-ray Mössbauer technique (CEMS/CXMS) is also available. The main concept of the RT MS is a table-top spectrometric bench with a control unit based on special-purpose hardware or standard PC platform. The first way offers a compact design and PC independent spectra collection system. The second setup, a PC-based system, which uses commercial devices and LabVIEW software, offers easy customization and enables advancement in spectrometer construction. The both types of control systems are able to operate special parts (velocity transducers, gamma-ray detectors) of unusual spectrometric benches. The standard velocity axis range is up to ±20 mm/s with a maximum nonlinearity of 0.1%. Applicable measuring conditions of presented TMSs cover a cryogenic temperature range from 1.5 up to 300 K and high temperature range from RT up to 1000 °C. With in-field low-temperature MS, we are able to analyze samples normally in the external magnetic fields up to 8 T (in temperature interval from 1.5 up to 300 K). In addition, special modes of measurements can be applied including backscattering gamma-ray geometry or measurement in an inert or controlled-humidity atmosphere. Technical details and construction aspects of spectrometers are presented.

  9. Double difference method in deep inelastic neutron scattering on the VESUVIO spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Andreani, C.; Colognesi, D.; Degiorgi, E.; Filabozzi, A.; Nardone, M.; Pace, E.; Pietropaolo, A. E-mail: antonino.pietropaolo@roma2.infn.it; Senesi, R

    2003-02-01

    The principles of the Double Difference (DD) method, applied to the neutron spectrometer VESUVIO, are discussed. VESUVIO, an inverse geometry spectrometer operating at the ISIS pulsed neutron source in the eV energy region, has been specifically designed to measure the single particle dynamical properties in condensed matter. The width of the nuclear resonance of the absorbing filter, used for the neutron energy analysis, provides the most important contribution to the energy resolution of the inverse geometry instruments. In this paper, the DD method, which is based on a linear combination of two measurements recorded with filter foils of the same resonance material but of different thickness, is shown to improve significantly the instrumental energy resolution, as compared with the Single Difference (SD) method. The asymptotic response functions, derived through Monte-Carlo simulations for polycrystalline Pb and ZrH{sub 2} samples, are analysed in both DD and SD methods, and compared with the experimental ones for Pb sample. The response functions have been modelled for two distinct experimental configurations of the VESUVIO spectrometer, employing {sup 6}Li-glass neutron detectors and NaI {gamma} detectors revealing the {gamma}-ray cascade from the (n,{gamma}) reaction, respectively. The DD method appears to be an effective experimental procedure for Deep Inelastic Neutron Scattering measurements on VESUVIO spectrometer, since it reduces the experimental resolution of the instrument in both {sup 6}Li-glass neutron detector and {gamma} detector configurations.

  10. Development of a multichannel gamma spectrometer with 4096 channels based in microcontroller, used for nuclear geophysics and environmental dosimetry

    International Nuclear Information System (INIS)

    Silva, Nilton; Hiodo, Francisco Yukio; Ribeiro, Fernando Brenha; Umisedo, Nancy Kumiko

    2007-01-01

    With the availability of analogical and digital components of high performance and accessible cost, it became possible to construct gamma spectrometer coupled to a multichannel analyzer of 4096 channels. The detector has a compensation system of gain drift by digital feedback using one reference radioactive source of 133 Ba This mean removes the necessity of stabilized temperature environment and allows the continuity a same measurement in case of drop in line voltage. The MCA analyser is compound by a ADC converter of 12 bits, and an 8 bits microcontroller of 8051 series. The development of resident program was carried through in free C compiler (SDCC),and linkage with an analyser system is made by RS232 serial port. Deadtime reduction of ADC converter is got by the use of ring memory structure, often common in telecommunication area. Another advantage of developed equipment is that all circuits, including high voltage power supply for polarization of photomultiplier tube, are supplied by automotive batteries. The power supplies are developed and assembled using Pulse Width Modulation (PWM) techniques, with yield higher than 80 %. Samples of 137 Cs and 60 Co, gave four photopeaks that were used to energy calibration. Nowadays samples of fertilizers and dehydrated legumes, kept in sealed containers in order to reach secular radioactive equilibrium, are being measured in time of the order of about 2 days each. The definitive values can be converted in %K, eU(ppm), eTh(ppm) or eventually in Bq/kg. (author)

  11. A study of radioactive elements of various rocks in Pattani Province with gamma ray spectrometer

    Directory of Open Access Journals (Sweden)

    Kaewtubtim, P.

    2002-01-01

    Full Text Available The radioactivity of the three elements, potassium, uranium and thorium, in rocks of various types in Pattani Province was investigated by using a gamma ray spectrometer. It was found that potassium contents in igneous rocks, sedimentary rocks and metamorphic rocks were 6.29 %, 2.21% and 1.54 % respectively. Uranium equivalent contents in igneous rock, sedimentary rocks and metamorphic rocks were found to be 22.51 ppm, 11.25 ppm and 14.13 ppm, while thorium contents in these rocks were 21.78 ppm, 18.88 ppm and 18.15 ppm respectively. The results obtained were similar to those reported by Pungtip Ranglek (1995 for igneous rock at Liwong Pluton site in Thepha, Na Thawi, Chana and Saba Yoi Districts, Songkhla Province, and were about six times higher than those reported by Kittichai Wattananikorn (1994 for igneous rock in the northern part of Thailand.

  12. Performance Analysis of Polarization Modulated DirectDetection Optical CDMA Systems over Turbulent FSO LinksModeled by the Gamma-Gamma Distribution

    Directory of Open Access Journals (Sweden)

    Fan Bai

    2015-01-01

    Full Text Available This paper proposes a theoretical study to characterize the transmission of optical code division multiple access (CDMA systems deploying polarization shift keying (PolSK over a free space optical (FSO link under the impact of atmospheric turbulence. In our analysis, a novel transceiver architecture for atmospheric OCDMA FSO systems based on polarization modulation with direct detection is proposed and discussed. A detailed analytical model for PolSK-OCDMA systems over a turbulent FSO link is provided. Further, we derive a closed-form bit error ratio (BER and outage probability expressions, taking into account the multiple-access interference (MAI, optical noise and the atmospheric turbulence effect on the FSO link modeled by the Gamma-Gamma distribution. Finally, the results of this study show the most significant parameters that degrade the transmission performance of the PolSK-OCDMA signal over FSO links and indicate that the proposed approach offers improved bit error ratio (BER performances compared to the on-off-keying (OOK modulation scheme in the presence of turbulence.

  13. Laser-Electron-Gamma-Source. Progress report, July 1986

    International Nuclear Information System (INIS)

    Dowell, D.H.; Fineman, B.; Giordano, G.; Kistner, OC.; Matone, G.; Sandorfi, A.M.; Schaerf, C.; Thorn, C.E.; Ziegler, W.

    1986-07-01

    When completed, the Laser Electron Gamma Source (LEGS) is expected to provide intense beams of monochromatic and polarized (circular or linear) gamma rays with energies up to 500 MeV. The gamma-ray beams will be produced by Compton backscattering uv laser light from the electrons circulating in a storage ring. Progress with installation of the facility is described, particularly the Ar-ion laser and tagging spectrometer. Tests of the tagging spectrometer coponents is reported, and a second laser is described for higher energy operation. Estimates are given of expected beam parameters. Experimental equipment for the planned research projects to be carried out at the LEGS facility is discussed

  14. Selection and optimization of spectrometric amplifiers for gamma spectrometry: part II - linearity, live time correction factors and software

    International Nuclear Information System (INIS)

    Moraes, Marco Antonio Proenca Vieira de; Pugliesi, Reinaldo

    1996-01-01

    The objective of the present work was to establish simple criteria to choose the best combination of electronic modules to achieve an adequate high resolution gamma spectrometer. Linearity, live time correction factors and softwares of a gamma spectrometric system composed by a Hp Ge detector have been studied by using several kinds of spectrometric amplifiers: Canberra 2021, Canberra 2025, Ortec 673 and Tennelec 244 and the MCA cards Ortec and Nucleus. The results showed low values of integral non-linearity for all spectrometric amplifiers connected to the Ortec and Nucleus boards. The MCA card should be able to correct amplifier dead time for 17 kcps count rates. (author)

  15. Gamma ray spectroscopy with Arduino UNO

    Science.gov (United States)

    Lavelle, C. M.

    2018-05-01

    We review a simple gamma ray spectrometer constructed on a solderless breadboard. The spectrometer's detector consists of a CsI(Tl) scintillator and silicon photomultiplier (SiPM) and its readout is facilitated by an Arduino UNO. The system is low cost and utilizes a minimum of components while still achieving satisfactory charge linearity and noise levels. This instrument can be used in instructional laboratories to introduce both radiation detection and analog signal processing concepts. We also expect it will be of interest to those seeking to introduce gamma spectroscopy to the expanding ecosystem of Arduino hardware.

  16. Airborne gamma-ray spectrometer and magnetometer survey. Volume I. Final report

    International Nuclear Information System (INIS)

    An airborne combined radiometric and magnetic survey was performed for the Department of Energy (DOE) over the area covered by the Mariposa, California and Nevada; Fresno, California; and Bakersfield, Caifornia 1:250,000 National Topographic Map Series (NTMS) 1 0 x 2 0 quadrangle maps. The survey was a part of DOE's National Aerial Radiometric Reconnaissance (ARR) program, which in turn is a part of the National Uranium Resource Evaluation (NURE) program. Data were collected by a helicopter equipped with a gamma-ray spectrometer having a large crystal volume, and a high sensitivity proton precession magnetometer. The radiometric system was calibrated at the Walker Field Calibration pads and the Lake Mead Dynamic Test range. Data quality was ensured throughout the survey by daily test flights and equipment checks. Radiometric data were corrected for live time, aircraft and equipment background, cosmic background, atmospheric radon, Compton scatter, and altitude dependence. The corrected data were statistically evaluated, plotted, and contoured to produce anomaly maps based on the radiometric response of individual geological units. These maps were interpreted and an anomaly interpretation map produced. Volume I contains a description of the systems used in the survey, a discussion of the calibration of the systems, the data processing procedures, the data display format, the interpretation rationale, and the interpretation methodology. A separate Volume II for each quadrangle contains the data displays and the interpretation results

  17. Optimization of the operational conditions of a multichannel analyzer gamma spectrometer

    International Nuclear Information System (INIS)

    Mosse, H.

    1974-01-01

    For the optimization of the operational conditions of a multichannel analyser gamma spectrometer, with two 3'' x 3'' NaI (Tl) crystals in opposition, several parameters were studied, which are responsable for the best counting efficiency, in each type of sample to be analysed. Thus, electronic conditions, shielding, sample holding, resolution, geometry (or the sample positioning between the detectors), were investigated. Self-absorption, sample density and the effects of the shape of the containers were also tested. For solid samples, (usually ashed), the best container was found to be a plastic cylinder, with the sample pressed inside. For liquid samples, plastic cylindric flasks were also found to be the best ones. Environmental samples were measured with internal standards for 137 Cs and 40 K. Results were compared with those obtained by physical (atomic adsorption for K) and radiochemical methods (Cs precipitation by amonium phosphomolibdate). Results show good agreement with the spectrometric analysis. For comparison with environmental samples, standards were prepared, in such a way that they could simulated their physical caracteristics. The minimum detectable activity was determined for 137 Cs. Results show values of 0.01 pCi/g for the 1 Kg samples, and 0.004 pCi/g for the 300g ones. By the measurement of 40 K, we found this value to be 0.02 mgK/g, in both cases. (author) [pt

  18. Implementation of a new gamma spectrometer on the MERARG loop: Application to the volatile fission products release measurement

    Energy Technology Data Exchange (ETDEWEB)

    Bernard, S.; Gleizes, B.; Pontillon, Y.; Hanus, E.; Ducros, G. [CEA, DEN, DEC, SA3C, F-13108, Saint Paul lez Durance, (France); Roure, C. [CEA, DEN, DTN, SMTA, F-13108, Saint Paul lez Durance, (France)

    2015-07-01

    The MERARG facility initially aims at the annealing of irradiated fuel samples to study the gaseous fission products release kinetics. In order to complete the evaluation of the source term potentially released during accidental situation, the MERARG experimental circuit has been enhanced with a new gamma spectrometer. This one is directly sighting the fuel and is devoted to the fission products release kinetics. Because of the specificities of the fuel measurements, it has been dimensioned and designed to match the specific requirements. The acquisition chain and the collimation system have been optimized for this purpose and a first set of two experiments have shown the good functioning of this new spectrometry facility. (authors)

  19. Long-term radiation damage to a spaceborne germanium spectrometer

    CERN Document Server

    Kurczynski, P; Hull, E L; Palmer, D; Harris, M J; Seifert, H; Teegarden, B J; Gehrels, N; Cline, T L; Ramaty, R; Sheppard, D; Madden, N W; Luke, P N; Cork, C P; Landis, D A; Malone, D F; Hurley, K

    1999-01-01

    The Transient Gamma-Ray Spectrometer aboard the Wind spacecraft in deep space has observed gamma-ray bursts and solar events for four years. The germanium detector in the instrument has gradually deteriorated from exposure to the approx 10 sup 8 p/cm sup 2 /yr(>100 MeV) cosmic-ray flux. Low-energy tailing and loss of efficiency, attributed to hole trapping and conversion of the germanium from n- to p-type as a result of crystal damage, were observed. Raising the detector bias voltage ameliorated both difficulties and restored the spectrometer to working operation. Together, these observations extend our understanding of the effects of radiation damage to include the previously unsuccessfully studied regime of long-term operation in space. (author)

  20. A molecular beam/quadrupole mass spectrometer system with synchronized beam modulation and digital waveform analysis

    Science.gov (United States)

    Pellett, G. L.; Adams, B. R.

    1983-01-01

    A performance evaluation is conducted for a molecular beam/mass spectrometer (MB/MS) system, as applied to a 1-30 torr microwave-discharge flow reactor (MWFR) used in the formation of the methylperoxy radical and a study of its subsequent destruction in the presence or absence of NO(x). The modulated MB/MS system is four-staged and differentially pumped. The results obtained by the MWFR study is illustrative of overall system performance, including digital waveform analysis; significant improvements over previous designs are noted in attainable S/N ratio, detection limit, and accuracy.

  1. Intensity modulated operating mode of the rotating gamma system.

    Science.gov (United States)

    Sengupta, Bishwambhar; Gulyas, Laszlo; Medlin, Donald; Koroknai, Tibor; Takacs, David; Filep, Gyorgy; Panko, Peter; Godo, Bence; Hollo, Tamas; Zheng, Xiao Ran; Fedorcsak, Imre; Dobai, Jozsef; Bognar, Laszlo; Takacs, Endre

    2018-05-01

    The purpose of this work was to explore two novel operation modalities of the rotating gamma systems (RGS) that could expand its clinical application to lesions in close proximity to critical organs at risk (OAR). The approach taken in this study consists of two components. First, a Geant4-based Monte Carlo (MC) simulation toolkit is used to model the dosimetric properties of the RGS Vertex 360™ for the normal, intensity modulated radiosurgery (IMRS), and speed modulated radiosurgery (SMRS) operation modalities. Second, the RGS Vertex 360™ at the Rotating Gamma Institute in Debrecen, Hungary is used to collect experimental data for the normal and IMRS operation modes. An ion chamber is used to record measurements of the absolute dose. The dose profiles are measured using Gafchromic EBT3 films positioned within a spherical water equivalent phantom. A strong dosimetric agreement between the measured and simulated dose profiles and penumbra was found for both the normal and IMRS operation modes for all collimator sizes (4, 8, 14, and 18 mm diameter). The simulated falloff and maximum dose regions agree better with the experimental results for the 4 and 8 mm diameter collimators. Although the falloff regions align well in the 14 and 18 mm collimators, the maximum dose regions have a larger difference. For the IMRS operation mode, the simulated and experimental dose distributions are ellipsoidal, where the short axis aligns with the blocked angles. Similarly, the simulated dose distributions for the SMRS operation mode also adopt an ellipsoidal shape, where the short axis aligns with the angles where the orbital speed is highest. For both modalities, the dose distribution is highly constrained with a sharper penumbra along the short axes. Dose modulation of the RGS can be achieved with the IMRS and SMRS modes. By providing a highly constrained dose distribution with a sharp penumbra, both modes could be clinically applicable for the treatment of lesions in close

  2. Efficiency calibration and minimum detectable activity concentration of a real-time UAV airborne sensor system with two gamma spectrometers.

    Science.gov (United States)

    Tang, Xiao-Bin; Meng, Jia; Wang, Peng; Cao, Ye; Huang, Xi; Wen, Liang-Sheng; Chen, Da

    2016-04-01

    A small-sized UAV (NH-UAV) airborne system with two gamma spectrometers (LaBr3 detector and HPGe detector) was developed to monitor activity concentration in serious nuclear accidents, such as the Fukushima nuclear accident. The efficiency calibration and determination of minimum detectable activity concentration (MDAC) of the specific system were studied by MC simulations at different flight altitudes, different horizontal distances from the detection position to the source term center and different source term sizes. Both air and ground radiation were considered in the models. The results obtained may provide instructive suggestions for in-situ radioactivity measurements of NH-UAV. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. A dosimetric comparison of fan-beam intensity modulated radiotherapy with gamma knife stereotactic radiosurgery for treating intermediate intracranial lesions

    International Nuclear Information System (INIS)

    Ma Lijun; Xia Ping; Verhey, Lynn J.; Boyer, Arthur L.

    1999-01-01

    Purpose: To compare and evaluate treatment plans for the fan-beam intensity modulated radiotherapy and the Gamma Knife radiosurgery for treating medium-size intracranial lesions (range 4-25 cm 3 ). Methods and Materials: Treatment plans were developed for the Leksell Gamma Knife and a fan-beam inverse treatment planning system for intensity modulated radiotherapy. Treatment plan comparisons were carried out using dose-volume histogram (DVH), tissue-volume ratio (TVR), and maximum dose to the prescription dose (MDPD) ratio. The study was carried out for both simulated targets and clinical targets with irregular shapes and at different locations. Results: The MDPD ratio was significantly greater for the Gamma Knife plans than for the fan-beam IMRT plans. The Gamma Knife plans produced equivalent TVR values to the fan-beam IMRT plans. Based on the DVH comparison, the fan-beam IMRT delivered significantly more dose to the normal brain tissue than the Gamma Knife. The results of the comparison were found to be insensitive to the target locations. Conclusion: The Gamma Knife is better than the fan-beam IMRT in sparing normal brain tissue while producing equivalent tumor dose conformity for treating medium-size intracranial lesions. However, the target dose homogeneity is significantly better for the fan-beam IMRT than for the Gamma Knife

  4. Neutron spectrometer using NE218 liquid scintillator

    International Nuclear Information System (INIS)

    Dance, J.B.; Francois, P.E.

    1976-01-01

    A neutron spectrometer has been constructed using NE218 liquid scintillator. Discrimination against electron-gamma events was obtained usng a charge-comparison pulse shape discrimination system. The resolution obtained was about 0.25 MeV F.W.H.M. at 2.0 MeV

  5. Nocardia brasiliensis Modulates IFN-gamma, IL-10, and IL-12 cytokine production by macrophages from BALB/c Mice.

    Science.gov (United States)

    Salinas-Carmona, Mario C; Zúñiga, Juan M; Pérez-Rivera, Luz I; Segoviano-Ramírez, Juan C; Vázquez-Marmolejo, Anna V

    2009-05-01

    Interferon-gamma (IFN-gamma) is a critical cytokine involved in control of different infections. Actinomycetoma is a chronic infectious disease mainly caused by the bacterium Nocardia brasiliensis, which destroys subcutaneous tissue, including bone. Currently, the mechanism of pathogenesis in N. brasiliensis infection is not known. Here, we demonstrate that N. brasiliensis induced an IFN-gamma response in serum after 24 h of infection, while, in infected tissue, positive cells to IFN-gamma appeared in 2 early peaks: the first was present only 3 h after infection, then transiently decreased; and the second peak appeared 12 h after infection and was independent of interleukin-10. Resident macrophages produced an immediate IFN-gamma response 1 h after in vitro infection, and spleen-positive cells began later. The phase of growth of N. brasiliensis affected cytokine production, and exposure of macrophages to Nocardia opsonized with either polyclonal anti-Nocardia antibodies or anti-P61 monoclonal antibody led to a suppression of cytokine production. Our report provides evidence that N. brasiliensis as an intracellular bacterium modulates macrophage cytokine production, which helps survival of the pathogen. Modulation of these cytokines may contribute to pathogenesis once this bacterium is inside the macrophage.

  6. Multi-dimensional analysis of high resolution {gamma}-ray data

    Energy Technology Data Exchange (ETDEWEB)

    Flibotte, S.; Huettmeier, U.J.; France, G. de; Haas, B.; Romain, P.; Theisen, Ch.; Vivien, J.P.; Zen, J. [Strasbourg-1 Univ., 67 (France). Centre de Recherches Nucleaires

    1992-12-31

    A new generation of high resolution {gamma}-ray spectrometers capable of recording high-fold coincidence events with a large efficiency will soon be available. Algorithms are developed to analyze high-fold {gamma}-ray coincidences. As a contribution to the software development associated with the EUROGAM spectrometer, the performances of computer codes designed to select multi-dimensional gates from 3-, 4- and 5-fold coincidence databases were tested. The tests were performed on events generated with a Monte Carlo simulation and also on real experimental triple data recorded with the 8{pi} spectrometer and with a preliminary version of the EUROGAM array. (R.P.) 14 refs.; 3 figs.; 3 tabs.

  7. GeMini: The Next Generation Mechanically-Cooled Germanium Spectrometer

    International Nuclear Information System (INIS)

    Burks, M.

    2008-01-01

    The next-generation mechanically-cooled germanium spectrometer has been developed. GeMini (GErmanium MINIature spectrometer) has been designed to bring high-resolution gamma-ray spectroscopy to a range of demanding field environments. Intended applications include short-notice and surprise inspections where positive nuclide identification of radioactive materials is required. GeMini weighs 2.75 kg (6 lbs) total including the detector, cryostat, cryocooler, batteries, electronics and readout. It is very low power allowing it to operate for 10 hours on a single set of rechargeable batteries. This instrument employs technology adapted from the gamma-ray spectrometer currently flying on NASA's Mercury MESSENGER spacecraft. Specifically, infrared shielding techniques allow for a vast reduction of thermal load. This in turn allows for a smaller, lighter-weight design, well-suited for a hand-held instrument. Two working prototypes have been built and tested in the lab. The target energy resolution is 3 keV fwhm or better for 1332 keV gamma-rays. The detectors currently achieve around 4.5 keV resolution, which is slightly higher than our goal due to microphonic noise. Our present work focuses on improving the resolution through mechanical and electronic means of reducing the microphonic noise. This paper will focus on the performance of the instrument and its applicability for inspectors in the field

  8. GEMS: Underwater spectrometer for long-term radioactivity measurements

    Energy Technology Data Exchange (ETDEWEB)

    Sartini, Ludovica, E-mail: ludovica.sartini@ingv.i [Istituto Nazionale di Geofisica e Vulcanologia (INGV), Sect.Roma 2, Roma (Italy); Genoa University, Genoa (Italy); Simeone, Francesco; Pani, Priscilla [' Sapienza' University and Istituto Nazionale di Fisica Nucleare (INFN), Sect.Roma, Roma (Italy); Lo Bue, Nadia; Marinaro, Giuditta [Istituto Nazionale di Geofisica e Vulcanologia (INGV), Sect.Roma 2, Roma (Italy); Grubich, Andry; Lobko, Alexander [Institute for Nuclear Problems (INP), Belarus State University, Minsk (Belarus); Etiope, Giuseppe [Istituto Nazionale di Geofisica e Vulcanologia (INGV), Sect.Roma 2, Roma (Italy); Capone, Antonio [' Sapienza' University and Istituto Nazionale di Fisica Nucleare (INFN), Sect.Roma, Roma (Italy); Favali, Paolo [Istituto Nazionale di Geofisica e Vulcanologia (INGV), Sect.Roma 2, Roma (Italy); Gasparoni, Francesco; Bruni, Federico [Tecnomare S.p.A., Venice (Italy)

    2011-01-21

    GEMS (Gamma Energy Marine Spectrometer) is a prototype of an autonomous radioactivity sensor for underwater measurements, developed in the framework for a development of a submarine telescope for neutrino detection (KM3NeT Design Study Project). The spectrometer is highly sensitive to gamma rays produced by {sup 40}K decays but it can detect other natural (e.g., {sup 238}U,{sup 232}Th) and anthropogenic radio-nuclides (e.g., {sup 137}Cs). GEMS was firstly tested and calibrated in the laboratory using known sources and it was successfully deployed for a long-term (6 months) monitoring at a depth of 3200 m in the Ionian Sea (Capo Passero, offshore Eastern Sicily). The instrument recorded data for the whole deployment period within the expected specifications. This monitoring provided, for the first time, a continuous time-series of radioactivity in deep-sea.

  9. High resolution gamma-ray spectroscopy applied to bulk sample analysis

    International Nuclear Information System (INIS)

    Kosanke, K.L.; Koch, C.D.; Wilson, R.D.

    1980-01-01

    A high resolution Ge(Li) gamma-ray spectrometer has been installed and made operational for use in routine bulk sample analysis by the Bendix Field Engineering Corporation (BFEC) geochemical analysis department. The Ge(Li) spectrometer provides bulk sample analyses for potassium, uranium, and thorium that are superior to those obtained by the BFEC sodium iodide spectrometer. The near term analysis scheme permits a direct assay for uranium that corrects for bulk sample self-absorption effects and is independent of the uranium/radium disequilibrium condition of the sample. A more complete analysis scheme has been developed that fully utilizes the gamma-ray data provided by the Ge(Li) spectrometer and that more properly accounts for the sample self-absorption effect. This new analysis scheme should be implemented on the BFEC Ge(Li) spectrometer at the earliest date

  10. Conceptual design of the radial gamma ray spectrometers system for α particle and runaway electron measurements at ITER

    Science.gov (United States)

    Nocente, M.; Tardocchi, M.; Barnsley, R.; Bertalot, L.; Brichard, B.; Croci, G.; Brolatti, G.; Di Pace, L.; Fernandes, A.; Giacomelli, L.; Lengar, I.; Moszynski, M.; Krasilnikov, V.; Muraro, A.; Pereira, R. C.; Perelli Cippo, E.; Rigamonti, D.; Rebai, M.; Rzadkiewicz, J.; Salewski, M.; Santosh, P.; Sousa, J.; Zychor, I.; Gorini, G.

    2017-07-01

    We here present the principles and main physics capabilities behind the design of the radial gamma ray spectrometers (RGRS) system for alpha particle and runaway electron measurements at ITER. The diagnostic benefits from recent advances in gamma-ray spectrometry for tokamak plasmas and combines space and high energy resolution in a single device. The RGRS system as designed can provide information on α ~ particles on a time scale of 1/10 of the slowing down time for the ITER 500 MW full power DT scenario. Spectral observations of the 3.21 and 4.44 MeV peaks from the 9\\text{Be}≤ft(α,nγ \\right){{}12}\\text{C} reaction make the measurements sensitive to α ~ particles at characteristic resonant energies and to possible anisotropies of their slowing down distribution function. An independent assessment of the neutron rate by gamma-ray emission is also feasible. In case of runaway electrons born in disruptions with a typical duration of 100 ms, a time resolution of at least 10 ms for runaway electron studies can be achieved depending on the scenario and down to a current of 40 kA by use of external gas injection. We find that the bremsstrahlung spectrum in the MeV range from confined runaways is sensitive to the electron velocity space up to E≈ 30 -40 MeV, which allows for measurements of the energy distribution of the runaway electrons at ITER.

  11. Airborne gamma-ray spectrometer and magnetometer survey: Barrow Quadrangle, Alaska. Final report. Volume I

    International Nuclear Information System (INIS)

    1981-03-01

    During the months of July-August 1980, Aero Service Division Western Geophysical Company of America conducted an airborne high sensitivity gamma-ray spectrometer and magnetometer survey over eleven (11) 3 0 x 1 0 and one (1) 4 0 x 1 0 NTMS quadrangles of the Alaskan North Slope. This report discusses the results obtained over the Barrow map area. The final data are presented in four different forms: on magnetic tape; on microfiche; in graphic form as profiles and histograms; and in map form as anomaly maps, flight path maps, and computer printer maps. The histograms and the multiparameter profiles are presented with the anomaly maps and flight path map in a separate bound volume. Complete data listings of both the reduced single record and the reduced averaged record data are found in the back of this report. The format of the printout of the microfiches and the format of the data files delivered on magnetic tape are in accordance with the specifications of the BFEC 1200-C and are described in appendices F through L of this report

  12. Airborne gamma-ray spectrometer and magnetometer survey, New Rockford Quadrangle, North Dakota. Final report

    International Nuclear Information System (INIS)

    1981-04-01

    An airborne high sensitivity gamma-ray spectrometer and magnetometer survey was conducted over eleven (11) 2 0 x 1 0 NTMS quadrangles located in the states of Minnesota and Wisconsin and seven (7) 2 0 x 1 0 NTMS quadrangles in North and South Dakota. The quadrangles located within the North and South Dakota survey area include Devil's Lake, New Rockford, Jamestown, Aberdeen, Huron, Mitchell, and Sioux Falls. This report discusses the results obtained over the New Rockford map area. Traverse lines were flown in an east-west direction at a line spacing of six (6) miles. Tie lines were flown north-south approximately twenty-four (24) miles apart. A total of 21,481 line miles of geophysical data were acquired, compiled, and interpreted during the survey, of which 1397 line miles are in this quadrangle. The purpose of this study is to acquire and compile geologic and other information with which to assess the magnitude and distribution of uranium resources and to determine areas favorable for the occurrence of uranium in the United States

  13. A Moessbauer effect spectrometer

    International Nuclear Information System (INIS)

    Fayek, M.K.; Abbas, Y.M.; Bahgat, A.A.

    1983-01-01

    A Moessbauer effect spectrometer of Harwell type is installed and put in operation. The driving system is of a constant acceleration mode with a velocity range 40mm/sec. and associated to a 1024 multichannel analyser working in a multiscalar time mode. The gamma ray sources are 50 mCi Co 57 in Pd and 20 mCi Snsup(119m) in Ba Sn(O) 3 . Measurements are taken with the source kept at room temperature, while the absorber can be maintained at various temperatures. Gamma ray resonance spectra of different standard samples are obtained. Zero velocity and magnetic field calibration curves are deduced. Examples of some Moessbauer spectra for running investigated materials with a comprehensive general description are also given

  14. Frontal eye fields control attentional modulation of alpha and gamma oscillations in contralateral occipitoparietal cortex

    NARCIS (Netherlands)

    Marshall, T.R.; O'Shea, J.; Jensen, O.; Bergmann, T.O.

    2015-01-01

    Covertly directing visuospatial attention produces a frequency-specific modulation of neuronal oscillations in occipital and parietal cortices: anticipatory alpha (8-12 Hz) power decreases contralateral and increases ipsilateral to attention, whereas stimulus-induced gamma (>40 Hz) power is boosted

  15. Mixed gamma emitting gas standard and method

    International Nuclear Information System (INIS)

    McFarland, R.C.; McFarland, P.A.

    1986-01-01

    The invention in one aspect pertains to a method of calibrating gamma spectroscopy systems for gas counting in a variety of counting containers comprising withdrawing a precision volume of a mixed gamma-emitting gas standard from a precision volume vial and delivering the withdrawn precision volume of the gas standard to the interior of a gas counting container. Another aspect of the invention pertains to a mixed gamma-emitting gas standard, comprising a precision spherical vial of predetermined volume, multiple mixed emitting gas components enclosed within the vial, and means for withdrawing from the vial a predetermined amount of the components wherein the gas standard is used to calibrate a gamma spectrometer system for gas counting over a wide energy range without the use of additional standards. A third aspect comprehends a gamma spectrometer calibration system for gas counting, comprising a precision volume spherical glass vial for receiving mixed multiisotope gas components, and two tubular arms extending from the vial. A ground glass stopcock is positioned on each arm, and the outer end of one arm is provided with a rubber septum port

  16. The GSF anticoincidence-shielded Ge(Li) gamma-ray spectrometer and its application to the analysis of environmental samples

    International Nuclear Information System (INIS)

    Hoetzl, H.; Winkler, R.

    1981-01-01

    A high-efficiency gamma-ray spectrometer has been designed and built to provide simultaneous anticoincidence and coincidence spectrometry of low-level environmental samples. The spectrometer consists of a large-volume Ge(Li) detector as the main detector and a well-type NaI(Tl) guard detector. The Ge(Li) detector is a closed-end coaxial detector housed in a crystal of the vertical dip-stick type. Its relative photopeak efficiency is 27.5%. The guard counter is a 23-cm-dia. by 23-cm-long NaI(Tl) crystal with a 7.8-cm-dia. by 18-cm-deep centre well. The passive shield consists of a 10-cm lead shield with copper and cadmium lining. The electronics is designed to operate independently and simultaneously in the anticoincidence mode as well as in the coincidence or in the normal passive shield mode. When operating in the anticoincidence mode the Compton edge of 137 Cs is reduced by a factor of 7.7 to provide a peak-to-Compton edge ratio of 480:1. Bulk samples up to about 300 cm 3 can be measured on the top of the detector end cap inside the well of the NaI(Tl) crystal. The lower limit of detection (1000 min counting time, 95% confidence level) for 137 Cs is 1.6 pCi in a 3.8-cm-dia. by 3.5-cm-high sample geometry. The design of the spectrometer, its properties and the application to investigations on the migration of radionuclides in the soil, the analysis of radioactive emissions of coal-fired power plants and to fallout studies are described. (author)

  17. GAMSOURCE - WRS system module number 38474 for calculating gamma-ray sources produced by neutron capture

    International Nuclear Information System (INIS)

    Grimstone, M.J.

    1978-06-01

    The WRS Modular Programming System has been developed as a means by which programmes may be more efficiently constructed, maintained and modified. In this system a module is a self-contained unit typically composed of one or more Fortran routines, and a programme is constructed from a number of such modules. This report describes one WRS module, the function of which is to calculate the source strength of gamma-rays arising from neutron capture in a system represented in one-dimensional geometry. The information given in this manual is of use both to the programmer wishing to incorporate the module in a programme, and to the user of such a programme. (author)

  18. Calculational approach to ionization spectrometer design

    International Nuclear Information System (INIS)

    Gabriel, T.A.

    1974-01-01

    Many factors contribute to the design and overall performance of an ionization spectrometer. These factors include the conditions under which the spectrometer is to be used, the required performance, the development of the hadronic and electromagnetic cascades, leakage and binding energies, saturation effects of densely ionizing particles, nonuniform light collection, sampling fluctuations, etc. The calculational procedures developed at Oak Ridge National Laboratory that have been applied to many spectrometer designs and that include many of the influencing factors in spectrometer design are discussed. The incident-particle types which can be considered with some generality are protons, neutrons, pions, muons, electrons, positrons, and gamma rays. Charged kaons can also be considered but with less generality. The incident-particle energy range can extend into the hundreds of GeV range. The calculations have been verified by comparison with experimental data but only up to approximately 30 GeV. Some comparisons with experimental data are also discussed and presented so that the flexibility of the calculational methods can be demonstrated. (U.S.)

  19. Several key problems on developing software system of portable computerized γ spectrometer

    International Nuclear Information System (INIS)

    Wu Yunping; Jia Wenyi; Fang Fang; Zhou Rongsheng; Le Renchang

    2000-01-01

    A portable Gamma spectrometer based on Notebook PC. settled the deficiency of other kind spectrometers based on MCU. Its software with powerful ability of file manager and graphic interface under Windows98 operating system realized processing data on field, which used to be accomplished in laboratory. Several key problems during developing its software were presented here

  20. Matrix of response functions for xenon gamma-ray detector

    International Nuclear Information System (INIS)

    Shustov, A.E.; Vlasik, K.F.; Grachev, V.M.; Dmitrenko, V.V.; Novikov, A.S.; P'ya, S.N.; Ulin, S.E.; Uteshev, Z.M.; Chernysheva, I.V.

    2014-01-01

    An approach of creation of response matrix using simulation GEANT4 gamma-ray Monte-Carlo method has been described for gamma-ray spectrometer based on high pressure xenon impulse ionization chamber with a shielding grid [ru

  1. The Polaris-H imaging spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Wahl, Christopher G., E-mail: chris@h3dgamma.com; Kaye, Willy R.; Wang, Weiyi; Zhang, Feng; Jaworski, Jason M.; King, Alexis; Boucher, Y. Andy; He, Zhong

    2015-06-01

    Recently, H3D has designed and introduced a gamma-ray imaging spectrometer system named Polaris-H. Polaris-H was designed to perform gamma spectroscopy and imaging throughout nuclear power plants. It integrates a 3D-position-sensitive pixelated CZT detector (20 mm×20 mm×15 mm), associated readout electronics, an embedded computer, a 5-h battery, and an optical camera in a portable water-proof enclosure. The total mass is about 4 kg, and the system startup time is 2 min. Additionally, it has a connection for a tablet, which displays a gamma-ray spectrum and isotope-specific images of the gamma-ray distribution in all directions in real time. List-mode data is saved to an external USB memory stick. Based on pixelated depth-sensing technology, spectroscopy is routinely better than 1.1% FWHM at 662 keV, and imaging efficiency at 662 keV varies less than a factor of two for all directions, except through the battery. Measurements have been performed in contaminated environments, in high radiation fields, and in cramped quarters.

  2. The Polaris-H imaging spectrometer

    International Nuclear Information System (INIS)

    Wahl, Christopher G.; Kaye, Willy R.; Wang, Weiyi; Zhang, Feng; Jaworski, Jason M.; King, Alexis; Boucher, Y. Andy; He, Zhong

    2015-01-01

    Recently, H3D has designed and introduced a gamma-ray imaging spectrometer system named Polaris-H. Polaris-H was designed to perform gamma spectroscopy and imaging throughout nuclear power plants. It integrates a 3D-position-sensitive pixelated CZT detector (20 mm×20 mm×15 mm), associated readout electronics, an embedded computer, a 5-h battery, and an optical camera in a portable water-proof enclosure. The total mass is about 4 kg, and the system startup time is 2 min. Additionally, it has a connection for a tablet, which displays a gamma-ray spectrum and isotope-specific images of the gamma-ray distribution in all directions in real time. List-mode data is saved to an external USB memory stick. Based on pixelated depth-sensing technology, spectroscopy is routinely better than 1.1% FWHM at 662 keV, and imaging efficiency at 662 keV varies less than a factor of two for all directions, except through the battery. Measurements have been performed in contaminated environments, in high radiation fields, and in cramped quarters

  3. Long-term variations in the gamma-ray background on SMM

    Science.gov (United States)

    Kurfess, J. D.; Share, G. H.; Kinzer, R. L.; Johnson, W. N.; Adams, J. H., Jr.

    1989-01-01

    Long-term temporal variations in the various components of the background radiation detected by the gamma-ray spectrometer on the Solar Maximum Mission are presented. The SMM gamma-ray spectrometer was launched in February, 1980 and continues to operate normally. The extended period of mission operations has provided a large data base in which it is possible to investigate a variety of environmental and instrumental background effects. In particular, several effects associated with orbital precession are introduced and discussed.

  4. Realisation of a {beta} spectrometer solenoidal and a double {beta} spectrometer at coincidence; Realisation d'un spectrometre {beta} solenoidal et d'un double spectrometre {beta} a coincidence

    Energy Technology Data Exchange (ETDEWEB)

    Moreau, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1955-06-15

    The two spectrometers have been achieved to tackle numerous problems of nuclear spectrometry. They possess different fields of application that complete themselves. The solenoidal spectrometer permits the determination of the energy limits of {beta} spectra and of their shape; it also permits the determination of the coefficients of internal conversion and reports {alpha}{sub K} / {alpha}{sub L} and it is especially efficient for the accurate energy levels of the {gamma} rays by photoelectric effect. The double coincidence spectrometer has been conceived to get a good efficiency in coincidence: indeed, the sum of the solid angles used for the {beta} and {gamma} emission is rather little lower to 4{pi} steradians. To get this efficiency, one should have sacrificed a little the resolution that is lower to the one obtained with the solenoidal spectrometer for a same brightness. Each of the elements of the double spectrometer can also be adapted to the study of angular correlations {beta}{gamma} and e{sup -}{gamma}. In this use, it is superior to the thin magnetic lens used up to here. The double spectrometer also permits the survey of the coincidences e{sup -}e{sup -}, e{sup -}{beta} of a equivalent way to a double lens; it can also be consider some adaptation for the survey of the angular correlations e{sup -}e{sup -}, e{sup -}{beta}. Finally, we applied the methods by simple spectrometry and by coincidence spectrometry, to the study of the radiances of the following radioelements: {sup 76}As (26 h), {sup 122}Sb (2,8 j), {sup 124}Sb (60 j), {sup 125}Sb (2,7 years). (M.B.) [French] Les deux spectrometres qui ont ete realises permettent d'aborder un grand nombre de problemes de spectrometrie nucleaire. Ils possedent des champs d'application tres differents qui se completent. Le spectrometre solenoidal permet la determination des energies limites des spectres {beta} et de leur forme; il permet aussi la determination des coefficients de conversion interne et des rapports

  5. Determination of planetary surfaces elemental composition by gamma and neutron spectroscopy

    International Nuclear Information System (INIS)

    Diez, B.

    2009-06-01

    Measuring the neutron and gamma ray fluxes produced by the interaction of galactic cosmic rays with planetary surfaces allow constraining the chemical composition of the upper tens of centimeters of material. Two different angles are proposed to study neutron and gamma spectroscopy: data processing and data interpretation. The present work is in line with two experiments, the Mars Odyssey Neutron Spectrometer (MONS) and the Selene Gamma Ray Spectrometer. A review of the processing operations applied to the MONS dataset is proposed. The resulting dataset is used to determine the depth of the hydrogen deposits below the Martian surface. In water depleted regions, neutron data allow constraining the concentration in elements likely to interact with neutrons. The confrontation of these results to those issued from the Gamma Ray Spectrometer onboard Mars Odyssey provides interesting insight on the geologic context of the Central Elysium Planitia region. These martian questions are followed by the study of the Selene gamma ray data. Although only preliminary processing has been done to date, qualitative lunar maps of major elements (Fe, Ca, Si, Ti, Mg, K, Th, U) have already been realized. (author)

  6. Modulation of induced gamma band activity in the human EEG by attention and visual information processing.

    Science.gov (United States)

    Müller, M M; Gruber, T; Keil, A

    2000-12-01

    Here we present a series of four studies aimed to investigate the link between induced gamma band activity in the human EEG and visual information processing. We demonstrated and validated the modulation of spectral gamma band power by spatial selective visual attention. When subjects attended to a certain stimulus, spectral power was increased as compared to when the same stimulus was ignored. In addition, we showed a shift in spectral gamma band power increase to the contralateral hemisphere when subjects shifted their attention to one visual hemifield. The following study investigated induced gamma band activity and the perception of a Gestalt. Ambiguous rotating figures were used to operationalize the law of good figure (gute Gestalt). We found increased gamma band power at posterior electrode sites when subjects perceived an object. In the last experiment we demonstrated a differential hemispheric gamma band activation when subjects were confronted with emotional pictures. Results of the present experiments in combination with other studies presented in this volume are supportive for the notion that induced gamma band activity in the human EEG is closely related to visual information processing and attentional perceptual mechanisms.

  7. A novel approach for predicting the response of the spectrometer for INTEGRAL satellite

    International Nuclear Information System (INIS)

    Kshetri, R.

    2013-01-01

    A basic phenomenological approach has been presented in three recent papers (Kshetri R., 2012. JINST 7, P04008; Kshetri R., 2012. JINST 7, P07006; Kshetri R., 2012. JINST 7, P12007) for understanding the operation of encapsulated type composite detectors including the SPI spectrometer. In the present paper, we have considered the fact that the experimental two-fold events between two detectors include the three and higher fold events between the same two detectors. The formalism has been further developed and the peak-to-total ratio of a general composite detector are predicted for energy region with no direct experimental information about them. At 8 MeV, the peak-to-total ratio for the SPI spectrometer and a very large detector (comprising of infinite number of single HPGe modules) are found to be 9% and 12%, respectively. The predictions for fold distribution of the SPI spectrometer are found to be in agreement with experimental data. Our formulation does not include ad-hoc fits, but expressions that are justifiable by probability flow arguments. Instead of using an empirical method or simulation, we present a novel approach for calculating the peak-to-total ratio of the SPI spectrometer for high gamma energies. - Highlights: ► Operation of SPI is described in terms of few probability amplitudes and a parameter. ► Predictions for peak-to-total ratio are given for inaccessible energy region. ► Predictions for fold distribution agree with experimental data up to 8 MeV. ► This paper is the sixth in the series of papers on composite germanium detectors

  8. Development of a mini-orange spectrometer for conversion electron study

    International Nuclear Information System (INIS)

    Mishra, N.R.; Chakravarty, V.; Chintalapudi, S.N.; Ghugre, S.S.; Sastry, D.L.

    1996-01-01

    Conversion electrons provide with an unique tool to have an unambiguous multipolarity assignment for the observed gamma transitions. The fabrication of an electron spectrometer to detect these conversion electrons is a non-trivial task

  9. Development results of portable gamma-radiation HPGe spectrometer with electric cooling for field applications

    International Nuclear Information System (INIS)

    Kondrat'ev, V.; Loshevich, E.; Pchelintsev, A.; Sokolov, A.; Gostilo, V.

    2015-01-01

    The paper presents development results of a portable spectrometer based on high purity germanium (HPGe spectrometer) with Stirling electric cooler for field applications. The spectrometer cryostat allows installation of HPGe coaxial detectors with efficiency up to 40% and planar detectors with sensitive area up to 3000 mm2. The detector cooling time is not more than 8 hours. Despite the mechanical vibrations due to electric cooler operation, the obtained energy resolution of the spectrometer with coaxial detector of 10% efficiency was less than 1,0 and 2,0 keV by energies 122 and 1332 keV accordingly. Miniature processor device (Android) allows control for all operation modes of the spectrometer, provides self diagnostics, initial procession, indication and spectra accumulation

  10. Environmental monitoring with in-situ gamma spectrometer; Umweltueberwachung mit in-situ-Gamma-Spektrometer

    Energy Technology Data Exchange (ETDEWEB)

    Reinhardt, S. [ENVINET GmbH, Haar (Germany)

    2014-01-20

    The in-situ gamma spectroscopy allows large area and continuous monitoring of the radio nuclides and there composition in the environment. In comparison to the gamma dose rate measurement the additional spectral information gives the possibility for a quick and effective action in the case of a man-made radiation exposition in the environment. The knowledge respectively localization of the possible nuclides, which a responsible for the increased dose rate, supports responsible organization in the quick identification of the situation, definition of the actions and tracking of the temporal and local process of the radiation exposition. Due to dedicate actions the risk for people and environment is reduced.

  11. A novel approach for modeling the cluster detector and the SPI spectrometer

    International Nuclear Information System (INIS)

    Kshetri, Ritesh

    2013-01-01

    Using available experimental data on cluster detector, predictions for the peak-to-total ratio have been given for energy region having no direct experimental information about them. The predictions for the fold distribution are found to be in agreement with the experimental data. The formulation here does not include ad-hoc fits, but expressions that are justifiable by probability flow arguments. Instead of using an empirical method or simulation, a novel approach for calculating the peak-to-total ratio of the cluster detector and the SPI spectrometer for high gamma energies has been presented here. This could provide guidance in designing new composite detectors and in performing experimental studies with the SPI spectrometer for high energy gamma-rays

  12. Conceptual design of the gamma-to-electron magnetic spectrometer for the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Y., E-mail: yhkim@lanl.gov; Herrmann, H. W.; Jorgenson, H. J.; Barlow, D. B.; Young, C. S.; Lopez, F. E.; Oertel, J. A.; Batha, S. H. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Stoeffl, W.; Casey, D.; Clancy, T. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Hilsabeck, T. [General Atomics, San Diego, California 92186 (United States); Moy, K. [National Security Technologies, Special Technologies Laboratory, Santa Barbara, California 93111 (United States)

    2014-11-15

    The Gamma-to-Electron Magnetic Spectrometer (GEMS) diagnostic is designed to measure the prompt γ-ray energy spectrum during high yield deuterium-tritium (DT) implosions at the National Ignition Facility (NIF). The prompt γ-ray spectrum will provide “burn-averaged” observables, including total DT fusion yield, total areal density (ρR), ablator ρR, and fuel ρR. These burn-averaged observables are unique because they are essentially averaged over 4π, providing a global reference for the line-of-sight-specific measurements typical of x-ray and neutron diagnostics. The GEMS conceptual design meets the physics-based requirements: ΔE/E = 3%–5% can be achieved in the range of 2–25 MeV γ-ray energy. Minimum DT neutron yields required for 15% measurement uncertainty at low-resolution mode are: 5 × 10{sup 14} DT-n for ablator ρR (at 0.2 g/cm{sup 2}); 2 × 10{sup 15} DT-n for total DT yield (at 4.2 × 10{sup −5} γ/n); and 1 × 10{sup 16} DT-n for fuel ρR (at 1 g/cm{sup 2})

  13. Constraining the Origin of Phobos with the Elpasolite Planetary Ice and Composition Spectrometer (EPICS) - Simulated Performance

    Science.gov (United States)

    Nowicki, S. F.; Mesick, K.; Coupland, D. D. S.; Dallmann, N. A.; Feldman, W. C.; Stonehill, L. C.; Hardgrove, C.; Dibb, S.; Gabriel, T. S. J.; West, S.

    2017-12-01

    Elpasolites are a promising new family of inorganic scintillators that can detect both gamma rays and neutrons within a single detector volume, reducing the instrument size, weight, and power (SWaP), all of which are critical for planetary science missions. The ability to distinguish between neutron and gamma events is done through pulse shape discrimination (PSD). The Elpasolite Planetary Ice and Composition Spectrometer (EPICS) utilizes elpasolites in a next-generation, highly capable, low-SWaP gamma-ray and neutron spectrometer. We present simulated capabilities of EPICS sensitivities to neutron and gamma-rays, and demonstrate how EPICS can constrain the origin of Phobos between the following three main hypotheses: 1) accretion after a giant impact with Mars, 2) co-accretion with Mars, and 3) capture of an external body. The MCNP6 code was used to calculate the neutron and gamma-ray flux that escape the surface of Phobos, and GEANT4 to model the response of the EPICS instrument on orbit around Phobos.

  14. Search for an annual modulation of dark-matter signals with a germanium spectrometer at the Sierra Grande Laboratory

    CERN Document Server

    Abriola, D.; Brodzinski, R.L.; Collar, J.I.; Di Gregorio, D.E.; Farach, H.A.; Garcia, E.; Gattone, A.O.; Guerard, C.K.; Hasenbalg, F.; Huck, H.; Miley, H.S.; Morales, A.; Morales, J.; Ortiz de Solorzano, A.; Puimedon, J.; Reeves, J.H.; Salinas, A.; Sarsa, M.L.; Villar, J.A.

    1999-01-01

    Data collected during three years with a germanium spectrometer at the Sierra Grande underground laboratory have been analyzed for distinctive features of annual modulation of the signal induced by WIMP dark matter candidates. The main motivation for this analysis was the recent suggestion by the DAMA/NaI Collaboration that a yearly modulation signal could not be rejected at the 90% confidence level when analyzing data obtained with a high-mass low-background scintillator detector. We performed two different analyses of the data: First, the statistical distribution of modulation-significance variables (expected from an experiment running under the conditions of Sierra Grande) was compared with the same variables obtained from the data. Second, the data were analyzed in energy bins as an independent check of the first result and to allow for the possibility of a crossover in the expected signal. In both cases no statistically significant deviation from the null result was found, which could support the hypothe...

  15. On-Line High Dose-rate Gamma Irradiation Test of the Profibus/DP module

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jai Wan; Choi, Young Soo; Kim, Chang Hoi; Koo, In Soo; Hong, Seok Boong [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2009-05-15

    The field bus data communication is considered for application in nuclear environments. The nuclear facilities, including nuclear power plants, high radioactivity waste disposals, reprocessing plants and thermonuclear fusion installations can benefit from the unique advantages of the field bus communication network for the smart field instruments and controls. A major problem which arises when dealing with one in these nuclear environments, in special circumstances such as the RCS (reactor coolant system) area, is the presence of high gamma-ray irradiation fields. Radioactive constraints for the DBA(design basis accident) qualification of the RTD transmitter installed in the inside of the RCS pump are typically on the order of 4kGy/h with total doses up to 10kGy. In order to use an industrial field bus communication network as an ad-hoc sensor data link in the vicinity of the RCS area of the nuclear power plant, the robust survivability of these system in such intense gamma-radiation fields therefore needs to be verified. We have conducted high dose-rate (up to 4kGy) gamma irradiation experiments on a profibus/DP communication module. In this paper we describe the evolution of its basic characteristics with high dose-rate gamma irradiation and shortly explain the observed phenomena.

  16. ICIT contribution to JET gamma-ray diagnostics enhancement

    International Nuclear Information System (INIS)

    Soare, S.; Curuia, M.; Zoita, V.

    2010-01-01

    Full text: Gamma-ray emission of tokamak plasmas is the result of the interaction of fast ions (fusion reaction products, including alpha particles, NBI ions, ICRH-accelerated ions) with main plasma impurities (e.g., carbon, beryllium). Gamma-ray diagnostics involve both gamma-ray imaging (cameras) and gamma-ray spectrometry (spectrometers). For the JET tokamak, gamma-ray diagnostics have been used to provide information on the characteristics of the fast ion population in plasmas. Two gamma-ray diagnostics enhancements project have been launched by JET and the MEdC/EURATOM Association has agreed to lead both of them with ICIT as projects leader. (authors)

  17. Gamma-ray tracking: Characterisation of the AGATA symmetric prototype detectors

    International Nuclear Information System (INIS)

    Boston, A.J.; Boston, H.C.; Cresswell, J.R.; Dimmock, M.R.; Nelson, L.; Nolan, P.J.; Rigby, S.; Lazarus, I.; Simpson, J.; Medina, P.; Santos, C.; Parisel, C.

    2007-01-01

    Each major technical advance in gamma-ray detection devices has resulted in significant new insights into the structure of atomic nuclei. The next major step in gamma-ray spectroscopy involves achieving the goal of a 4pi ball of Germanium detectors by using the technique of gamma-ray energy tracking in electrically segmented Germanium crystals. The resulting spectrometer will have an unparalleled level of detection power for nuclear electromagnetic radiation. Collaborations have been established in Europe (AGATA) [J. Simpson, Acta Phys. Pol. B 36 (2005) 1383. ] and the USA (GRETA/GRETINA) to build gamma-ray tracking spectrometers. This paper discusses the performance of the AGATA (Advanced Gamma Tracking Array) symmetric prototype detectors that have been tested at University of Liverpool. The use of a fully digital data acquisition system has allowed detector charge pulse shapes from a selection of well defined photon interaction positions to be analysed, yielding important information on the position sensitivity of the detector

  18. Gamma-ray tracking: Characterisation of the AGATA symmetric prototype detectors

    Energy Technology Data Exchange (ETDEWEB)

    Boston, A.J. [Oliver Lodge Laboratory, University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom)]. E-mail: ajboston@liv.ac.uk; Boston, H.C. [Oliver Lodge Laboratory, University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Cresswell, J.R. [Oliver Lodge Laboratory, University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Dimmock, M.R. [Oliver Lodge Laboratory, University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Nelson, L. [Oliver Lodge Laboratory, University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Nolan, P.J. [Oliver Lodge Laboratory, University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Rigby, S. [Oliver Lodge Laboratory, University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Lazarus, I. [STFC Daresbury Laboratory, Daresbury, Warrington WA4 4AD (United Kingdom); Simpson, J. [STFC Daresbury Laboratory, Daresbury, Warrington WA4 4AD (United Kingdom); Medina, P. [Institut de Recherches Subatomiques, Strasbourg BP28 67037 (France); Santos, C. [Institut de Recherches Subatomiques, Strasbourg BP28 67037 (France); Parisel, C. [Institut de Recherches Subatomiques, Strasbourg BP28 67037 (France)

    2007-08-15

    Each major technical advance in gamma-ray detection devices has resulted in significant new insights into the structure of atomic nuclei. The next major step in gamma-ray spectroscopy involves achieving the goal of a 4pi ball of Germanium detectors by using the technique of gamma-ray energy tracking in electrically segmented Germanium crystals. The resulting spectrometer will have an unparalleled level of detection power for nuclear electromagnetic radiation. Collaborations have been established in Europe (AGATA) [J. Simpson, Acta Phys. Pol. B 36 (2005) 1383. ] and the USA (GRETA/GRETINA) to build gamma-ray tracking spectrometers. This paper discusses the performance of the AGATA (Advanced Gamma Tracking Array) symmetric prototype detectors that have been tested at University of Liverpool. The use of a fully digital data acquisition system has allowed detector charge pulse shapes from a selection of well defined photon interaction positions to be analysed, yielding important information on the position sensitivity of the detector.

  19. Modulator Effect of Turmeric on Oxidative Damage in Whole Body Gamma Irradiated rats

    International Nuclear Information System (INIS)

    Amin, H.H.; Abdou, M.I.

    2012-01-01

    Because of its penetrating power and its ability to travel great distances, gamma rays are considered the primary hazard to the population during most radiological emergencies. So, there is a need to develop medical countermeasures to protect the first responders and remediation workers from biomedical effect of ionizing radiation. Turmeric has been reported to have many beneficial health effects, including a strong anti-oxidant effect, anti-inflammatory and anti-microbial properties. In the present study, turmeric was investigated as a therapeutic agent against hazards induced by ionizing radiation on kidney, liver, urinary and serum calcium levels and blood counts. A daily dose of 0.5 g/kg body weight was used in whole body gamma irradiated female rats with 3 Gy. Radiation effects were followed up for four weeks post irradiation. The results revealed that the administration of turmeric post-irradiation resulted in a significant inhibition in the frequency of radiation induced oxidative damage. It could be concluded that definite turmeric dose exerts a vital modulator role against gamma irradiation hazard

  20. Geometrically weighted semiconductor Frisch grid radiation spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    McGregor, D.S. [Dept. of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI 48109-2104 (United States); Rojeski, R.A. [Etec Systems, Inc., 26460 Corporate Ave., Hayward, CA 94545 (United States); He, Z. [Dept. of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI 48109-2104 (United States); Wehe, D.K. [Dept. of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI 48109-2104 (United States); Driver, M. [eV Products, 375 Saxonburg Blvd., Saxonburg, PA 16056 (United States); Blakely, M. [eV Products, 375 Saxonburg Blvd., Saxonburg, PA 16056 (United States)

    1999-02-11

    A new detector geometry is described with relatively high gamma ray energy resolution at room temperature. The device uses the geometric weighting effect, the small pixel effect and the Frisch grid effect to produce high gamma ray energy resolution. The design is simple and easy to construct. The device performs as a gamma ray spectrometer without the need for pulse shape rejection or correction, and it requires only one signal output to any commercially available charge sensitive preamplifier. The device operates very well with conventional NIM electronic systems. Presently, room temperature (23 deg. C) energy resolutions of 2.68% FWHM at 662 keV and 2.45% FWHM at 1.332 MeV have been measured with a 1 cm{sup 3} prism shaped CdZnTe device.

  1. Development and Calibration of the ART-XC Mirror Modules for the Spectrum Rontgen Gamma Mission

    Science.gov (United States)

    Ramsey, B.; Gubarev, M.; Elsner, R.; Kolodziejczak, J.; Odell, S.; Swartz, D.; Pavlinsky, M.; Tkachenko, A.; Lapshov, I.

    2013-01-01

    The Spectrum-Röntgen-Gamma (SRG) mission is a Russian-lead X-ray astrophysical observatory that carries two co-aligned X-ray telescope systems. The primary instrument is the German-led extended ROentgen Survey with an Imaging Telescope Array (eROSITA), a 7-module X-ray telescope system that covers the energy range from 0.2-12 keV. The complementary instrument is the Astronomical Roentgen Telescope -- X-ray Concentrator (ART-XC or ART), a 7-module Xray telescope system that provides higher energy coverage, up to 30 keV.

  2. Car-borne survey of natural background gamma dose rate in Canakkale region (Turkey)

    International Nuclear Information System (INIS)

    Turhan, S.; Arikan, I. H.; Oquz, F.; Aezdemir, T.; Yuecel, B.; Varinlioqlu, A.; Koese, A.

    2012-01-01

    Natural background gamma radiation was measured along roads in the environs of Canakkale region by using a car-borne spectrometer system with a plastic gamma radiation detector. In addition, activity concentrations of 238 U, 226 Ra, 232 Th and 40 K in soil samples from the Canakkale region were determined by using a gamma spectrometer with an HPGe detector. A total of 92 856 data of the background gamma dose rate were collected for the Canakkale region. The background gamma dose rate of the Canakkale region was mapped using ArcGIS software, applying the geostatistical inverse distance-weighted method. The average and population-weighted average of the gamma dose are 55.4 and 40.6 nGy h -1 , respectively. The corresponding average annual effective dose to the public ranged from 26.6 to 96.8 μSv. (authors)

  3. Study and validation of a gamma-ray spectrometer for the remote analysis of the chemical composition of planetary surfaces: application to a mission to the planet Mercury

    International Nuclear Information System (INIS)

    Pirard, B.

    2006-12-01

    This work deals with the design of a gamma-ray spectrometer for the remote analysis of the chemical composition of planetary surfaces and was performed in the frame of a mission scenario to explore the planet Mercury. The research studies consisted first in characterizing the detection performances of a gamma-ray spectrometer using a high-purity germanium crystal cooled actively at cryogenic temperatures. The high energy resolution of the detector allows an accurate measurement of the chemical composition for the main elements from oxygen to uranium. Thereafter the studies dealt with the critical issues addressed for the use of such a detector onboard a mission to the inner solar system. The radiation damage caused by solar protons in germanium crystals was investigated by experimental and numerical means. It has been shown that the detector resolution begins getting damaged for proton fluences over 5*10 8 p/cm 2 . An annealing session where the crystal is heated up to 80 C degrees for a 4-day period allows the detector to get back a sufficient resolution. Annealing over 100 C degrees gives back the detector its initial resolution. Finally, a numerical thermal model of the instrument as well as some tests on a thermal mockup were performed to validate the thermal design of the instrument

  4. Relative branching ratio of the {eta}{yields}{pi}{sup 0}{gamma}{gamma} decay channel

    Energy Technology Data Exchange (ETDEWEB)

    Knecht, N.; Papandreou, Z.; Lolos, G.J.; Benslama, K.; Huber, G.M.; Li, S.; Bekrenev, V.; Briscoe, W.J.; Grosnick, D.; Isenhower, D.; Koetke, D.D.; Kozlenko, N.G.; Kruglov, S.; Manley, D.M.; Manweiler, R.; McDonald, S.; Olmsted, J.; Shafi, A.; Stanislaus, T.D.S

    2004-06-03

    The {eta}{yields}{pi}{sup 0}{gamma}{gamma} rare decay was measured at the AGS with the Crystal Ball photon spectrometer and its relative branching ratio was extracted to be B{sub 1}=(8.3{+-}2.8{+-}1.4)x10{sup -4}, based on the analysis of 3x10{sup 7} detected {eta} mesons. This leads to a lower partial width for this eta channel than past measurements and is in line with chiral perturbation theory calculations.

  5. Input-dependent frequency modulation of cortical gamma oscillations shapes spatial synchronization and enables phase coding.

    Science.gov (United States)

    Lowet, Eric; Roberts, Mark; Hadjipapas, Avgis; Peter, Alina; van der Eerden, Jan; De Weerd, Peter

    2015-02-01

    Fine-scale temporal organization of cortical activity in the gamma range (∼25-80Hz) may play a significant role in information processing, for example by neural grouping ('binding') and phase coding. Recent experimental studies have shown that the precise frequency of gamma oscillations varies with input drive (e.g. visual contrast) and that it can differ among nearby cortical locations. This has challenged theories assuming widespread gamma synchronization at a fixed common frequency. In the present study, we investigated which principles govern gamma synchronization in the presence of input-dependent frequency modulations and whether they are detrimental for meaningful input-dependent gamma-mediated temporal organization. To this aim, we constructed a biophysically realistic excitatory-inhibitory network able to express different oscillation frequencies at nearby spatial locations. Similarly to cortical networks, the model was topographically organized with spatially local connectivity and spatially-varying input drive. We analyzed gamma synchronization with respect to phase-locking, phase-relations and frequency differences, and quantified the stimulus-related information represented by gamma phase and frequency. By stepwise simplification of our models, we found that the gamma-mediated temporal organization could be reduced to basic synchronization principles of weakly coupled oscillators, where input drive determines the intrinsic (natural) frequency of oscillators. The gamma phase-locking, the precise phase relation and the emergent (measurable) frequencies were determined by two principal factors: the detuning (intrinsic frequency difference, i.e. local input difference) and the coupling strength. In addition to frequency coding, gamma phase contained complementary stimulus information. Crucially, the phase code reflected input differences, but not the absolute input level. This property of relative input-to-phase conversion, contrasting with latency codes

  6. Comparison of backgrounds in OSO-7 and SMM spectrometers and short-term activation in SMM

    Science.gov (United States)

    Dunphy, P. P.; Forrest, D. J.; Chupp, E. L.; Share, G. H.

    1989-01-01

    The backgrounds in the OSO-7 Gamma-Ray Monitor and the Solar Maximum Mission Gamma-Ray Spectrometer are compared. After scaling to the same volume, the background spectra agree to within 30 percent. This shows that analyses which successfully describe the background in one detector can be applied to similar detectors of different sizes and on different platforms. The background produced in the SMM spectrometer by a single trapped-radiation belt passage is also studied. This background is found to be dominated by a positron-annihilation line and a continuum spectrum with a high energy cutoff at 5 MeV.

  7. A Compton-suppressed spectrometer for studies of chaos in nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Shriner, J.F. Jr. [Tennessee Technological Univ., Cookeville (United States); Bilpuch, E.G. [Duke University Press, Durham, NC (United States); Bybee, C.R. [Triangle Universities Nuclear Lab., Durham, NC (United States); Mitchell, G.E. [Triangle Universities Nuclear Lab., Durham, NC (United States); Moore, E.F. [Triangle Universities Nuclear Lab., Durham, NC (United States); Shriner, J.D. [Triangle Universities Nuclear Lab., Durham, NC (United States); Westerfeldt, C.R. [Duke University Press, Durham, NC (United States)

    1995-05-01

    One approach to studying chaos in quantum systems utilizes the statistical behavior of eigenvalues. Such analyses require data of very high quality, since both completeness and purity are essential. The design of a Compton-suppressed {gamma}-ray spectrometer for the purpose of establishing a nearly complete level scheme in {sup 30}P via the {sup 29}Si(p, {gamma}) reaction is described. Design criteria and implementation are discussed, and early results from the system are presented. (orig.).

  8. Environmental measurement-while-drilling-gamma ray spectrometer (EMWD-GRS) system technology demonstration plan for use at the Savannah River Site F-Area Retention Basin

    International Nuclear Information System (INIS)

    Williams, C.V.; Lockwood, G.J.; Normann, R.A.; Gruebel, R.D.

    1996-08-01

    The Environmental Measurement-While-Drilling-Gamma Ray Spectrometer (EMWD-GRS) system represents an innovative blend of new and existing technology that provides the capability of producing real-time environmental and drillbit data during drilling operations. This demonstration plan presents information on the EMWD-GRS technology, demonstration design, Cs-137 contamination at the Savannah River Site F-Area Retention Basin, responsibilities of demonstration participants, and the policies and procedures for the demonstration to be conducted at the Savannah River Site F-Area Retention Basin. The EMWD-GRS technology demonstration will consist of continuously monitoring for gamma-radiation contamination while drilling two horizontal boreholes below the backfilled retention basin. These boreholes will pass near previously sampled vertical borehole locations where concentrations of contaminant levels are known. Contaminant levels continuously recorded by the EMWD-GRS system during drilling will be compared to contaminant levels previously determined through quantitative laboratory analysis of soil samples

  9. Environmental measurement-while-drilling-gamma ray spectrometer (EMWD-GRS) system technology demonstration plan for use at the Savannah River Site F-Area Retention Basin

    Energy Technology Data Exchange (ETDEWEB)

    Williams, C.V.; Lockwood, G.J.; Normann, R.A. [Sandia National Labs., Albuquerque, NM (United States); Gruebel, R.D. [Tech Reps, Inc., Albuquerque, NM (United States)

    1996-08-01

    The Environmental Measurement-While-Drilling-Gamma Ray Spectrometer (EMWD-GRS) system represents an innovative blend of new and existing technology that provides the capability of producing real-time environmental and drillbit data during drilling operations. This demonstration plan presents information on the EMWD-GRS technology, demonstration design, Cs-137 contamination at the Savannah River Site F-Area Retention Basin, responsibilities of demonstration participants, and the policies and procedures for the demonstration to be conducted at the Savannah River Site F-Area Retention Basin. The EMWD-GRS technology demonstration will consist of continuously monitoring for gamma-radiation contamination while drilling two horizontal boreholes below the backfilled retention basin. These boreholes will pass near previously sampled vertical borehole locations where concentrations of contaminant levels are known. Contaminant levels continuously recorded by the EMWD-GRS system during drilling will be compared to contaminant levels previously determined through quantitative laboratory analysis of soil samples.

  10. Rapid monitoring of gaseous radionuclides using a portable spectrometer

    International Nuclear Information System (INIS)

    Chung, C.; Tsai, C.H.

    1995-01-01

    A field gamma ray spectrometer, consisting of a portable high purity germanium detector, portable multichannel analyser, and a notebook computer, was used to conduct in situ rapid scanning of radioactive Ar, Kr and Xe isotopes in the air around a nuclear facility. The portable gamma ray spectrometer was calibrated using Ar, Kr, and Xe radioisotopes, activated in a research reactor and released in a sealed chamber. The unit was further tested inside the reactor containment to monitor the concentration of 41 Ar. In a typical one hour field measurement, the detection limits for some rare gas radionuclides corresponded to dose rates around 0.1 nSv.h -1 , which is far less than the dose rate induced by derived air concentrations imposed by the authority. The dose rate due to ground level concentrations of gaseous radionuclides dispersed from a source, such a nuclear facility or nuclear test, can be monitored in a short period using the portable unit. (Author)

  11. Determination of data correction coefficients and the sensitivities of the KIER air-borne gamma-ray spectrometer survey system

    International Nuclear Information System (INIS)

    Koo, J.H.; Cho, D.H.; Park, Y.S.

    1982-01-01

    In air-borne gamma-ray spectrometer survey, the observed data must be corrected for the background, Compton scattering and flight altitude. And the corrected data are usually converted into the radiometric elements equivalents of the ground, using the sensitivities of the survey system. Accordingly, the correction coefficients and the sensitivities are determined as follows for the KIER air-borne survey system. The stripping or Compton scattering coefficients α, β and γ at the ground level were first determined on the basis of the gamma-ray count rates due to the 5 concrete calibration pads of the Soosaek Airbase, together with the radiometric elements concentrations of the core samples taken from the pads. As for the determination of the exponential altitude coefficients anti μ(K), anti μ(U), anti μ(Th) and anti μ(Tc), the count rates observed over the Hongseong Test Strip of about 3 km length were used after they had been corrected for the background and Compton scattering. The background count rates mainly caused by the air-craft as well as cosmic radiations were determined with the data taken over the West Sea near Anmyon Island, Chung-cheongnam-do. And the corrected count rates observed over the Strip, combined with the average radiometric elements concentrations of the Strip, yielded the sensitivities k(K), k(U) and k(Th) at the 400 feet flight altitude. (author)

  12. The nonlinear light output of NaI(Tl) detectors in the Modular Total Absorption Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Rasco, B.C., E-mail: crasco@lsu.edu [Department of Physics and Astronomy, Louisiana State University, Baton Rouge, LA 70803 (United States); Fijałkowska, A.; Karny, M. [Faculty of Physics, University of Warsaw, Pasteura 5, PL-02093 Warszawa (Poland); Rykaczewski, K.P. [Physics Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Wolińska-Cichocka, M. [Physics Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Oak Ridge Associated Universities, Oak Ridge, TN 37831 (United States); Heavy Ion Laboratory, University of Warsaw, Warsaw PL-02-093 (Poland); Grzywacz, R.; Goetz, K.C. [Department of Physics and Astronomy, University of Tennessee, Knoxville, TN 37966 (United States)

    2015-07-11

    A new detector array, the Modular Total Absorption Spectrometer (MTAS), was commissioned at the Holifield Radioactive Ion Beam Facility (HRIBF) at Oak Ridge National Lab (ORNL). Total absorption gamma spectra measured with MTAS are expected to improve beta-feeding patterns and beta strength functions in fission products. MTAS is constructed out of hexagonal NaI(Tl) detectors with a unique central module surrounded by 18 identical crystals assembled in three rings. The total NaI(Tl) mass of MTAS is over 1000 kg. The response of the central and other 18 MTAS modules to γ-radiation was simulated using the GEANT4 toolkit modified to analyze the nonlinear light output of NaI(Tl). A detailed description of the GEANT4 modifications made is discussed. Simulated energy resolution of MTAS modules is found to agree well with the measurements for single γ transitions of 662 keV ({sup 137}Cs) with 8.2% full width half maximum (FWHM), 835 keV ({sup 54}Mn) with FWHM of 7.5% FWHM, and 1115 keV ({sup 65}Zn) with FWHM of 6.5%. Simulations of single and multiple γ-rays from {sup 60}Co are also discussed.

  13. Investigation of background processes in the KATRIN main spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Axel [Karlsruhe Institute of Technology (KIT), Institut fuer Kernphysik (IKP) (Germany); Collaboration: KATRIN-Collaboration

    2016-07-01

    The KArlsruhe TRItium Neutrino experiment aims to probe the mass of the electron antineutrino in a model-independent way with an unsurpassed sensitivity of m{sub ν}=200 meV/c{sup 2} (90% C.L.). In order to determine the neutrino mass, the energy spectrum of electrons from the tritium β-decay is analyzed by a high-resolution electrostatic spectrometer which is based on the MAC-E filter principle. To keep the influence of the spectrometer background on the neutrino mass sensitivity small, KATRIN aims for a background level of 0.01 cps. For the investigation of different background components such as cosmic muons, external gamma radiation and the radioactive decay of isotopes in the volume of the spectrometer or on its surface, a series of dedicated measurements were performed with a combined system of main spectrometer and detector. This talk presents the results of measurements focusing on the secondary electron production at the inner surface of the spectrometer and compare them with electro-magnetic electron tracking simulations performed with the KATRIN developed simulation software KASSIOPEIA.

  14. Automatic calibration of gamma spectrometers

    International Nuclear Information System (INIS)

    Tluchor, D.; Jiranek, V.

    1989-01-01

    The principle is described of energy calibration of the spectrometric path based on the measurement of the standard of one radionuclide or a set of them. The entire computer-aided process is divided into three main steps, viz.: the insertion of the calibration standard by the operator; the start of the calibration program; energy calibration by the computer. The program was selected such that the spectrum identification should not depend on adjustment of the digital or analog elements of the gamma spectrometric measuring path. The ECL program is described for automatic energy calibration as is its control, the organization of data file ECL.DAT and the necessary hardware support. The computer-multichannel analyzer communication was provided using an interface pair of Canberra 8673V and Canberra 8573 operating in the RS-422 standard. All subroutines for communication with the multichannel analyzer were written in MACRO 11 while the main program and the other subroutines were written in FORTRAN-77. (E.J.). 1 tab., 4 refs

  15. The design and construction of a scintillation pair spectrometer for the detection of {gamma}-rays in the energy range 2-20 MeV; Realisation d'un spectrometre a scintillations et a paires pour la detection des rayonnements {gamma} d'energie comprise entre 2 et 20 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Longequeue, J P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-15

    The scintillation pair spectrometer is designed to allow the measurement of the energy of {gamma} rays in the range 2 to 20 MeV. Such an instrument is chosen because of its main features: high energy resolution and ease of working. Against this, however, the efficiency is low. It was possible to tolerate this low efficiency because of the facts that the {gamma}-rays studied emanated from (p, {gamma}) reactions and that the two electrostatic acceleration available could provide beams of 500 {mu}A having energy maxima at 300 and 600 keV. We used the {gamma} rays produced by the reactions {sup 23}Na (p, {gamma}) {sup 24}Mg, {sup 19}F (p, {alpha} {gamma}) {sup 16}O and {sup 7}Li (p, {gamma}) {sup 8}Be as well as the {gamma} rays emitted by sources of RTh and of {sup 24}Na. Under these conditions the spectrometer attained a resolving power of 6,5 {+-} 0,5 per cent at 6,1 MeV and it was able to separate the 14,8 and 17,6 MeV lines produced by the reaction {sup 7}Li (p, {gamma}) {sup 8}Be. As well as this, the efficiency which varied from 2.10{sup -4} to 1,7.10{sup -3} between 2 and 20 MeV was well above the efficiencies already obtained with this type of instrument. (author) [French] Le spectrometre a scintillations et a paires presente dans cette these a pour but de mesurer l'energie des rayonnements {gamma} dans la bande de 2 a 20 MeV. Le choix d'un tel appareil est du a ses caracteristiques essentielles: bonne resolution en energie et maniabilite. Par contre, son efficacite est faible. Nous avons pu tolerer cette faible efficacite car les rayonnements {gamma} que nous avons etudies provenaient de reactions (p, {gamma}) et les deux accelerateurs electrostatiques dont nous disposions pouvaient fournir des faisceaux de 500 {mu}A avec des energies maximum de 300 et 600 keV. Nous avons utilise les rayonnements {gamma} produits par les reactions {sup 23}Na (p, {gamma}) {sup 24}Mg, {sup 19}F (p, {alpha} {gamma}) {sup 16}O et {sup 7}Li (p, {gamma}) {sup 8}Be ainsi que les

  16. Gamma-ray tracking - A new detector concept for nuclear spectroscopy

    International Nuclear Information System (INIS)

    Gast, W.

    2001-01-01

    In the framework of an European collaboration the nest generation of large efficiency, high resolution spectrometers for nuclear spectroscopy is under development. The new spectrometers are large volume, segmented Ge-detectors featuring 3D position sensitivity in order to allow Gamma-Ray Tracking. That is, knowing the interaction positions and the energies released at each interaction, the track each gamma-ray follows during its scattering process inside the detector volume can be reconstructed on basis of the Compton-scattering formula. The resulting high add-back efficiency an effective granularity significantly improves peak-to-total ratio, efficiency, and Doppler-broadening of the spectrometer. In this contribution the states of the project concerning detector design and development of digital signal processing techniques to achieve an optimal 3D position sensitivity is presented. (authors)

  17. Data management and analysis techniques used in the near X-ray and gamma-ray spectrometer systems

    International Nuclear Information System (INIS)

    McClanahan, T.P.; Trombka, J.I.; Floyd, S.R.; Boynton, W.V.; Mikheeva, I.; Bailey, H.; Liewicki, C.; Bhangoo, J.; Starr, R.; Clark, P.E.; Evans, L.G.; Squyres, S.; McNutt, R.; Brueckner, J.

    1999-01-01

    The NEAR Earth Asteroid Rendezvous (NEAR) spacecraft will encounter the 433Eros asteroid for a one year orbital mission in December 1998. Its on-board remote sensing instrumentation includes X-ray and gamma-ray (XGRS) spectrometers. NEAR is an orbital mission and long integrations over spatially specific asteroid regions are generally not possible. A methodology for simulating longer integrations has been developed for XGRS and uses unique management, correlative and analytical ground systems to render mapping data products. Evaluation of the spatial environment is accomplished through virtual renderings of the asteroid surface giving incidence, emission and surface roughness factors. Extended computer plate modeling information is employed to optimize ground computer systems processing time. Interactive visualization systems have been developed to manage close to a million spectra that will be collected during the encounter. Feedback systems are employed to inspect, tag and calibrate spectral data products. Mission planning, systems development and managerial responsibilities have been distributed to cooperating science organizations at The Goddard Space Flight Center, The University of Arizona, Cornell University, The Applied Physics Laboratory and The Max Plank Institute

  18. Airborne gamma-ray spectrometer and magnetometer survey: Peoria, Decater, Belleville Quadrangles, (IL). Final report

    International Nuclear Information System (INIS)

    1981-01-01

    An airborne combined radiometric and magnetic survey was performed for the Department of Energy (DOE) over the area covered by the Peoria, Decatur, and Belleville, 1:250,000 National Topographic Map Series (NTMS), quadrangle maps. The survey was part of DOE's National Uranium Resource Evaluation (NURE) program. Data were collected by a helicopter equipped with a gamma-ray spectrometer with a large crystal volume, and with a high sensitivity proton procession magnetometer. The radiometric system was calibrated at the Walker Field Calibration pads and the Lake Mead Dynamic Test Range. Data quality was ensured during the survey by daily test flights and equipment checks. Radiometric data were corrected for live time, aircraft and equipment background, cosmic background, atmospheric radon, Compton scatter, and altitude dependence. The corrected data were statistically evaluated, plotted, and contoured to produce anomaly maps based on the radiometric response of individual geological units. The anomalies were interpreted and an interpretation map produced. Volume I contains a description of the systems used in the survey, a discussion of the calibration of the systems, the data collection procedures, the data processing procedures, the data presentation, the interpretation rationale, and the interpretation methodology. A separate Volume II for each quadrangle contains the data displays and the interpretation results

  19. Miniature Neutron-Alpha Activation Spectrometer

    Science.gov (United States)

    Rhodes, E.; Goldsten, J.

    2001-01-01

    We are developing a miniature neutron-alpha activation spectrometer for in situ analysis of samples including rocks, fines, ices, and drill cores, suitable for a lander or Rover platform, that would meet the severe mass, power, and environmental constraints of missions to the outer planets. In the neutron-activation mode, a gamma-ray spectrometer will first perform a penetrating scan of soil, ice, and loose material underfoot (depths to 10 cm or more) to identify appropriate samples. Chosen samples will be analyzed in bulk in neutron-activation mode, and then the sample surfaces will be analyzed in alpha-activation mode using Rutherford backscatter and x-ray spectrometers. The instrument will provide sample composition over a wide range of elements, including rock-forming elements (such as Na, Mg, Si, Fe, and Ca), rare earths (Sm and Eu for example), radioactive elements (K, Th, and U), and light elements present in water, ices, and biological materials (mainly H, C, O, and N). The instrument is expected to have a mass of about l kg and to require less than 1 W power. Additional information is contained in the original extended abstract.

  20. Stabilization of spectra provided by a gamma-ray spectrometer. Application to the construction of a stabilizer; Stabilisation des spectres fournis par un spectrometre a rayons gamma. Application a la realisation d'un stabilisateur

    Energy Technology Data Exchange (ETDEWEB)

    Detourne, G [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-06-15

    This research is concerned with the stabilization of spectra provided by a gamma-ray spectrometer. It is required to hold the calibration straight line of the spectrometer in a position which is fixed initially to better than 5x10{sup -5} channel. A prototype numerical stabilizer has been constructed : the SPECTROSTAB; it is made up of two independent control loops; one of these makes the spectrometer gain depend on the derivatives of a reference peak at high energies; the other makes the origin of the energy scale depend on the derivatives of a second reference peak at low energies A theoretical study of the behaviour of a control loop shows that a direct action stabilizer gives the most accurate stabilization; the loss in resolving power on the theoretical peaks of the spectra attains about 1 % with a scintillation detector, and 10 % with a semi-conductor detector. Various tests show that the expected results are obtained and that the displacement of the spectral peaks produced by the derivatives are hidden by errors in the calculation of the peak abscissae. (author) [French] Cette etude a pour objet la stabilisation des spectres fournis par un spectrometre a rayons gamma. On veut maintenir la droite d'etalonnage du spectrometre dans une position fixee initialement a mieux de 6.10{sup -5} canal pres. On realise un prototype de stabilisateur numerique, le SPECTROSTAB; il comprend deux boucles d'asservissement independantes; l'une d'elles asservit le gain du spectrometre aux derives d'un pic de reference aux hautes energies; l'autre asservit l'origine de l'echelle des energies aux derives d'un second pic de reference aux basses energies. Une etude theorique du comportement d'une boucle d'asservissement montre qu'un stabilisateur a action directe permet la stabilisation la plus precise; la perte en resolution sur les pics theoriques des spectres atteint environ 1 % avec un detecteur a scintillateur et 10 % avec un detecteur a semi-conducteur. Divers essais montrent

  1. Application of modular neutron spectrometer to measure neutron spectra from fission of 252Cf

    International Nuclear Information System (INIS)

    Szeflinski, Z.; Osuch, S.; Popkiewicz, M.; Wilhelmi, Z.; Zelazny, Z.

    1996-01-01

    The neutron spectrometer MONA (Modular Neutron Array) and its test has been described. The spectrometers consist of eight BC-501A liquid scintillator detectors of BICRON which allow one to distinguish between the pulses from gamma quanta and neutrons using pulse shape discrimination (PSD) method. The electronic equipment for the PSD and the test result using the 252 Cf radioactive source are presented

  2. A new measurement of the rare decay eta -> pi^0 gamma gamma with the Crystal Ball/TAPS detectors at the Mainz Microtron

    Energy Technology Data Exchange (ETDEWEB)

    Nefkens, B M; Prakhov, S; Aguar-Bartolom��, P; Annand, J R; Arends, H J; Bantawa, K; Beck, R; Bekrenev, V; Bergh��user, H; Braghieri, A; Briscoe, W J; Brudvik, J; Cherepnya, S; Codling, R F; Collicott, C; Costanza, S; Danilkin, I V; Denig, A; Demissie, B; Dieterle, M; Downie, E J; Drexler, P; Fil' kov, L V; Fix, A; Garni, S; Glazier, D I; Gregor, R; Hamilton, D; Heid, E; Hornidge, D; Howdle, D; Jahn, O; Jude, T C; Kashevarov, V L; K��ser, A; Keshelashvili, I; Kondratiev, R; Korolija, M; Kotulla, M; Koulbardis, A; Kruglov, S; Krusche, B; Lisin, V; Livingston, K; MacGregor, I J; Maghrbi, Y; Mancel, J; Manley, D M; McNicoll, E F; Mekterovic, D; Metag, V; Mushkarenkov, A; Nikolaev, A; Novotny, R; Oberle, M; Ortega, H; Ostrick, M; Ott, P; Otte, P B; Oussena, B; Pedroni, P; Polonski, A; Robinson, J; Rosner, G; Rostomyan, T; Schumann, S; Sikora, M H; Starostin, A; Strakovsky, I I; Strub, T; Suarez, I M; Supek, I; Tarbert, C M; Thiel, M; Thomas, A; Unverzagt, M; Watts, D P; Werthmueller, D; Witthauer, L

    2014-08-01

    A new measurement of the rare, doubly radiative decay eta->pi^0 gamma gamma was conducted with the Crystal Ball and TAPS multiphoton spectrometers together with the photon tagging facility at the Mainz Microtron MAMI. New data on the dependence of the partial decay width, Gamma(eta->pi^0 gamma gamma), on the two-photon invariant mass squared, m^2(gamma gamma), as well as a new, more precise value for the decay width, Gamma(eta->pi^0 gamma gamma) = (0.33+/-0.03_tot) eV, are based on analysis of 1.2 x 10^3 eta->pi^0 gamma gamma decays from a total of 6 x 10^7 eta mesons produced in the gamma p -> eta p reaction. The present results for dGamma(eta->pi^0 gamma gamma)/dm^2(gamma gamma) are in good agreement with previous measurements and recent theoretical calculations for this dependence.

  3. Development of ultrahigh energy resolution gamma spectrometers for nuclear safeguards

    International Nuclear Information System (INIS)

    Drury, O.B.; Velazquez, M.; Dreyer, J.G.; Friedrich, S.

    2009-01-01

    We are developing superconducting ultrahigh resolution gamma-detectors for non-destructive analysis (NDA) of nuclear materials, and specifically for spent fuel characterization in nuclear safeguards. The detectors offer an energy resolution below 100 eV FWHM at 100 keV, and can therefore significantly increase the precision of NDA at low energies where line overlap affects the errors of the measurement when using germanium detectors. They also increase the peak-to-background ratio and thus improve the detection limits for weak gamma emissions from the fissile Pu and U isotopes at low energy in the presence of an intense Compton background from the fission products in spent fuel. Here we demonstrate high energy resolution and high peak-to-background ratio of our superconducting Gamma detectors, and discuss their relevance for measuring actinides in spent nuclear fuel. (author)

  4. Gamma spectrometry and plastic-scintillator inherent background

    International Nuclear Information System (INIS)

    Pomerantsev, V.V.; Gagauz, I.B.; Mitsai, L.I.; Pilipenko, V.S.; Solomonov, V.M.; Chernikov, V.V.; Tsirlin, Y.A.

    1988-01-01

    The authors measured the energy resolution for a linear dependence of light yield on gamma radiation energy of gamma spectrometers based on plastic scintillation detectors for several plastic scintillators. If there were several gamma lines from the source the line with the highest energy was used to eliminate distortion due to overlap from the Compton background from gamma radiation of higher energy. Attenuation lengths were calculated. The tests were based on three modes of interaction between the gamma radiation and the scintillator: Compton scattering, the photoelectric effect, and pair formation. The contribution from light collection was also considered. The scintillators tested included polystyrene, polymethyl methacrylate, cesium iodide, and sodium iodide. Gamma sources included cesium 137, sodium 22, potassium 40, yttrium 88, thorium 232, and plutonium-beryllium

  5. Determination of beta and gamma radioactivity on the coal

    International Nuclear Information System (INIS)

    Suhardi; Mulyono; Sutanto WW; Rosidi

    2013-01-01

    Radioactivity in coal, botton ash and fly ash. This determination was carried out to know each the radioactivity of β gross, γ gross on the coal, botton ash and fly ash, which accommodation of environment data the present in PLTU Paiton Probolinggo. Samples taken preparation and analysis based on the procedures of environmental radioactivity analysis. The radioactivity on the PLTU Paiton Probolinggo detected by beta gross Spectrometer with Geiger Muller (GM) and gamma Spectrometer with Ge(Li) detector. The result indicates that radioactivity concentration of beta and gamma gross are (95,57-308,26) Bq/kg and (1,374 - 31,677) Bq/kg respectively. (author)

  6. The worldwide NORM production and a fully automated gamma-ray spectrometer for their characterization

    International Nuclear Information System (INIS)

    Xhixha, G.; Callegari, I.; Guastaldi, E.; De Bianchi, S.; Fiorentini, G.; Universita di Ferrara, Ferrara; Istituto Nazionale di Fisica Nucleare; Kaceli Xhixha, M.

    2013-01-01

    Materials containing radionuclides of natural origin and being subject to regulation because of their radioactivity are known as Naturally Occurring Radioactive Material (NORM). By following International Atomic Energy Agency, we include in NORM those materials with an activity concentration, which is modified by human made processes. We present a brief review of the main categories of non-nuclear industries together with the levels of activity concentration in feed raw materials, products and waste, including mechanisms of radioisotope enrichments. The global management of NORM shows a high level of complexity, mainly due to different degrees of radioactivity enhancement and the huge amount of worldwide waste production. The future tendency of guidelines concerning environmental protection will require both a systematic monitoring based on the ever-increasing sampling and high performance of gamma-ray spectroscopy. On the ground of these requirements a new low-background fully automated high-resolution gamma-ray spectrometer MCA R ad has been developed. The design of lead and cooper shielding allowed to reach a background reduction of two order of magnitude with respect to laboratory radioactivity. A severe lowering of manpower cost is obtained through a fully automation system, which enables up to 24 samples to be measured without any human attendance. Two coupled HPGe detectors increase the detection efficiency, performing accurate measurements on small sample volume (180 cm 3 ) with a reduction of sample transport cost of material. Details of the instrument calibration method are presented. MCA R ad system can measure in less than one hour a typical NORM sample enriched in U and Th with some hundreds of Bq kg -1 , with an overall uncertainty less than 5 %. Quality control of this method has been tested. Measurements of three certified reference materials RGK-1, RGU-2 and RGTh-1 containing concentrations of potassium, uranium and thorium comparable to NORM have

  7. Wide band ENDOR spectrometer

    International Nuclear Information System (INIS)

    Mendonca Filho, C.

    1973-01-01

    The construction of an ENDOR spectrometer operating from 0,5 to 75 MHz within a single band, with ore Klystron and homodine detection, and no fundamental changes on the electron spin resonance spectrometer was described. The ENDOR signal can be detected both by amplitude modulation of the frequency field, or direct detection of the ESR output, which is taken to a signal analyser. The signal-to-noise ratio is raised by averaging rather than filtering avoiding the use of long time constants, providing natural line widths. The experimental apparatus and the spectra obtained are described. A discussion, relating the ENDOR line amplitudes with the experimental conditions is done and ENDOR mechanism, in which there is a relevant presence of cross relaxation is proposed

  8. Multichannel Dynamic Fourier-Transform IR Spectrometer

    Science.gov (United States)

    Balashov, A. A.; Vaguine, V. A.; Golyak, Il. S.; Morozov, A. N.; Khorokhorin, A. I.

    2017-09-01

    A design of a multichannel continuous scan Fourier-transform IR spectrometer for simultaneous recording and analysis of the spectral characteristics of several objects is proposed. For implementing the design, a multi-probe fiber is used, constructed from several optical fibers connected into a single optical connector and attached at the output of the interferometer. The Fourier-transform spectrometer is used as a signal modulator. Each fiber is individually mated with an investigated sample and a dedicated radiation detector. For the developed system, the radiation intensity of the spectrometer is calculated from the condition of the minimum spectral resolution and parameters of the optical fibers. Using the proposed design, emission spectra of a gas-discharge neon lamp have been recorded using a single fiber 1 mm in diameter with a numerical aperture NA = 0.22.

  9. Bayesian Inference on the Memory Parameter for Gamma-Modulated Regression Models

    Directory of Open Access Journals (Sweden)

    Plinio Andrade

    2015-09-01

    Full Text Available In this work, we propose a Bayesian methodology to make inferences for the memory parameter and other characteristics under non-standard assumptions for a class of stochastic processes. This class generalizes the Gamma-modulated process, with trajectories that exhibit long memory behavior, as well as decreasing variability as time increases. Different values of the memory parameter influence the speed of this decrease, making this heteroscedastic model very flexible. Its properties are used to implement an approximate Bayesian computation and MCMC scheme to obtain posterior estimates. We test and validate our method through simulations and real data from the big earthquake that occurred in 2010 in Chile.

  10. Performance of BICM-based QAM-SIM OWC over gamma-gamma turbulence channels

    KAUST Repository

    Malik, Muhammad Talha

    2015-05-01

    We derive a series expression for the pair-wise error probability (PEP) of bit interleaved coded modulation (BICM)-based subcarrier intensity modulation (SIM) optical wireless communication (OWC) system employing M^{2}-ary quadrature amplitude modulation ( M^{2} -QAM) over the Gamma-Gamma turbulence channels. Using this expression, we develop an upper bound (UB) to predict the bit-error rate performance of such system. Simulation results are presented to verify the analytical results. We also develop an asymptotic UB which reveals that the diversity order depends on the smaller channel parameter and the free distance of the convolutional code. © 1997-2012 IEEE.

  11. Calibration and application of a HPGe gamma spectrometer for in-situ measurements

    International Nuclear Information System (INIS)

    Xiao Xuefu; Yue Qingyu

    1992-02-01

    The principle and methods of the calibration for an in-situ γ spectrometer are introduced. The calibration for a portable HPGe γ spectrometer has been completed. The N f /A(peak count rate per unit activity in soil) and N f /D(peak count rate per unit absorbed dose rate in the air) are listed. The uncertainties of the calibration factors are estimated. The in-situ measurements have been carried out in surroundings near the nuclear facilities and the data are compared with those measured by other methods

  12. A superconducting electron spectrometer

    International Nuclear Information System (INIS)

    Guttormsen, M.; Huebel, H.; Grumbkow, A. von

    1983-03-01

    The set-up and tests of an electron spectrometer for in-beam conversion electron measurements are described. A superconducting solenoid is used to transport the electrons from the target to cooled Si(Li) detectors. The solenoid is designed to produce either a homogeneous axially symmetric field of up to 2 Tesla or a variety of field profiles by powering the inner and outer set of coils of the solenoid separately. The electron trajectories resulting for various field profiles are discussed. In-beam electron spectra taken in coincidence with electrons, gammas and alpha-particles are shown. (Auth.)

  13. Study of gamma irradiated polyethylenes by temperature modulated differential scanning calorimetry

    International Nuclear Information System (INIS)

    Secerov, B.; Galovic, S.; Trifunovic, S.; Milicevic, D.; Suljovrujic, E.

    2011-01-01

    Complete text of publication follows. The various polyethylenes (PEs) and effects of high energy radiation on theirs structures were widely studied in the past using conventional Differential Scanning Calorimetry (DSC) measurements. In this work, we applied the Temperature Modulated Differential Scanning Calorimetry (TMDSC) technique in order to obtain more information about the influence of initial structural differences and gamma radiation on the evolution in structure and thermal properties of different polyethylenes. For this reason, low density polyethylene (LDPE), linear low density polyethylene (LLDPE) and high density polyethylene (HDPE) samples were exposed to gamma radiation, in air, to a wide range of absorbed doses (up to 2400 kGy). The separation of the total heat flow TMDSC signal into a reversing and nonreversing part enabled to observed the low temperature enthalpy relaxation (related to the existence of the 'rigid amorphous phase') and recrystallization processes as well as to follow their and/or radiation-induced evolution of melting in a more revealing manner compared to the case of the conventional DSC. Consequently, our results indicate that TMDSC could improve the understanding of radiation-induced effects in polymers.

  14. Implementation and application of the gaussian decomposition software for NaI gamma-ray spectrometry data

    International Nuclear Information System (INIS)

    Zeng Lihui; Wang Nanping Tian Gui

    2011-01-01

    In order to extract the information of peaks in different energy from the data of overlapping peaks in environmental gamma spectrometer, a spectrum data Gaussian decomposition soft is designed based on least- square Gaussian fitting method. The interface of this software is friendly, it can complete the decomposition of overlapping peaks in gamma spectrometer quickly by the way of man-machines interactive. The result that applied gamma spectrometry to data analysis in the field measurement indicates that the Gaussian decomposition soft can efficiently extract 137 Cs from overlapping peaks which has significance to assess the human nuclide contamination of environment. (authors)

  15. Usage of portable spectrometers for prevention of radioactive and nuclear materials illicit trafficking

    International Nuclear Information System (INIS)

    Bystrov, Evgenij; Antonau, Uladzimir; Gurinovich, Uladzimir; Kazhamiakin, Valery; Petrov, Vitaly; Shulhovich, Heorhi; Tischenko, Siarhei

    2008-01-01

    Full text: It is publicly known that radioactive and nuclear materials can be shielded not only with passive protection but also be masked with legally transported radioactive substances. These radioactive substances can be contained as medical radionuclides incorporated in human body or in cargos with high content of natural isotopes 40 K, 232 Th, 238 U, etc. This constitutes an additional serious obstacle to detection of radioactive substances trafficking. Dosimeters, search monitors or radiation portal monitors have insufficient capability for this objective. It is necessary to use much more intellectual instruments that can detect both gamma radiation and other types of radiation (neutron, alpha, beta), recognize radionuclide type and identify it with high probability. To address these objectives, we have developed portable scintillation gamma spectrometers AT6101 and AT6102 with neutron radiation detection and measurement of surface contamination with alpha and beta particles. Gamma scintillation spectrometry methods using NaI(Tl) crystal allow to detect source of gamma radiation, measure ambient dose rate equivalent of gamma radiation and identify radionuclide composition. The implemented spectrometry method of gamma radiation dose rate measurement using 'spectrum-dose' function allows to measure ambient dose rate equivalent of gamma radiation with relative error up to 20%. Radionuclide identification is based on channel-by-channel spectrum convolution with the second derivative from Gaussian function. Peak search and analysis and peak position comparison to energy values of gamma lines of library radionuclides is performed in convolution spectrum. Analysis of relative intensity of detected gamma lines with peak detection threshold overrun allows qualitative definition of radionuclide composition in object under examination. The special feature of the spectrometers is LED stabilization through spectrometric path. The stabilization system covers PEM, pre

  16. Development of gallium arsenide gamma spectrometric detector

    International Nuclear Information System (INIS)

    Kobayashi, T.; Kuru, I.

    1975-03-01

    GaAs semiconductor material has been considered to be a suitable material for gamma-ray spectrometer operating at room temperature since it has a wid-band gap, larger than that of silicon and germanium. The basic objective of this work is to develop a GaAs gamma-ray spectrometric detector which could be used for gamma spectrometric measurement of uranium and plutonium in nuclear fuel safeguards. Liquid phase epitaxial techniques using iron (Fe) as dopant have been developed in making high purity GaAs crystals suitable for gamma-ray spectrometer operating at room temperature. Concentration of Fe in the epitaxial crystal was controlled by initial growth temperature. The best quality epitaxial crystal was obtained under the following conditions: starting temperature is about 800degC, the proportion of Fe to Ga solvent is 1 to 300. Carrier concentration of epitaxial crystals grown distributed in the ranges of 10 12 cm -3 to 10 14 cm -3 at room temperature. The thickness of the crystals ranged from 38 μm to 120 μm. Au-GaAs surface barrier detector was made of epitaxial crystal. Some of the detector were encapsulated in a can with a 50 μm Be window by welding a can to the detector holder. The detector with high energy resolution and good charge collecting characteristics was selected by alpha spectrometry at room temperature. Energy resolution of the detector for gamma-rays up to about 200 keV was very good at room temperature operation. The best energy resolutions taken with a GaAs detector were 3 keV (fwhm) and 3.8 keV for 241 Am 59.6 keV and 57 Co 122 keV, respectively, at room temperature. In order to study the applicability of the detector for nuclear safeguards, the measurements of 235 U gamma-ray spectrum have been carried out at room temperature. It was clarified that the gamma-ray spectrum of enriched U sample could be measured in high resolution with GaAs detector at room temperature, and that the content of 235 U in enriched U sources could be determined by

  17. Use of microcontroller in gamma-ray spectrometer construction using NaI(Tl) sensor, with emphasis in multichannel analyzer, to applications in nuclear and environmental geophysics; Uso de microcontrolador na construcao de espectrometro gama com sensor de NaI(Tl), com enfase em analisador multicanal, para aplicacao em geofisica nuclear e ambiental

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Nilton

    2005-07-01

    In this work of nuclear geophysical instrumentation the main purpose was the development of a gamma-ray spectrometer prototype with multi channel analyzer, since the spectroscopic amplifier until your firmware. The heart of the digital part was an ATMEL 8 bits microcontroller (AT89S8252). All circuits were made and assembled in the Laboratory of Applied Geophysical Instrumentation (LIGA) of IAG-USP. A microcontroller software was completely developed in C ANSI language using the Small Device C Compiler version 2.4.8, that is a free software distributed under General Public License (GPL). At first, microcontroller was used to change all digital circuit of one classic SCINTREX GAD-6 differential gamma-ray spectrometer. Measurement times with order of 2 days became possible, and it could work in non climate ambient. Then, after this stage, had been started the development of a multichannel analyzer (MCA) working in pulse height analyzer mode with 4096 channels capacity, to use in many kinds of nuclear detection. Besides it, was developed an automatic gain system for photopeak stabilization, by the use of one radioactive source ({sup 133}Ba). This automatic gain system is very important in the case of NaI(Tl) scintillometric detectors, due PMT sensitivity with temperature and aging of some laboratory electronic circuits. Two power supplies with high stability, using pulse width modulation (PWM) techniques were developed, in order to all system became free of electrical line break off. One PWM power polarizes a photo multiplier tube (PMT) with high voltage and another supplies remaining developed circuits. Calibration in energy using standards sources {sup 137}Cs and {sup 60}Co showed that gamma detector developed has a good linearity and low thermal drift, even working in absent of air-conditioned. Concentrations measurements of K, U and Th were made in samples of soils, vegetables, etc. (author)'

  18. Acupuncture analgesia involves modulation of pain-induced gamma oscillations and cortical network connectivity.

    Science.gov (United States)

    Hauck, Michael; Schröder, Sven; Meyer-Hamme, Gesa; Lorenz, Jürgen; Friedrichs, Sunja; Nolte, Guido; Gerloff, Christian; Engel, Andreas K

    2017-11-24

    Recent studies support the view that cortical sensory, limbic and executive networks and the autonomic nervous system might interact in distinct manners under the influence of acupuncture to modulate pain. We performed a double-blind crossover design study to investigate subjective ratings, EEG and ECG following experimental laser pain under the influence of sham and verum acupuncture in 26 healthy volunteers. We analyzed neuronal oscillations and inter-regional coherence in the gamma band of 128-channel-EEG recordings as well as heart rate variability (HRV) on two experimental days. Pain ratings and pain-induced gamma oscillations together with vagally-mediated power in the high-frequency bandwidth (vmHF) of HRV decreased significantly stronger during verum than sham acupuncture. Gamma oscillations were localized in the prefrontal cortex (PFC), mid-cingulate cortex (MCC), primary somatosensory cortex and insula. Reductions of pain ratings and vmHF-power were significantly correlated with increase of connectivity between the insula and MCC. In contrast, connectivity between left and right PFC and between PFC and insula correlated positively with vmHF-power without a relationship to acupuncture analgesia. Overall, these findings highlight the influence of the insula in integrating activity in limbic-saliency networks with vagally mediated homeostatic control to mediate antinociception under the influence of acupuncture.

  19. Analysis of rocking curve measurements of LiF flight crystals for the objective crystal spectrometer on SPECTRUM-X-GAMMA

    DEFF Research Database (Denmark)

    Halm, I.; Wiebicke, H.-J.; Geppert, U.R.M.E.

    1993-01-01

    The Objective Crystal Spectrometer on the SPECTRUM-X-GAMMA satellite will use three types of natural crystals LiF(220), Si(111), RAP(001), and a multilayer structure providing high-resolution X- ray spectroscopy of Fe, S, O, and C line regions of bright cosmic X-ray sources. 330 - 360 LiF(220......) crystals of dimensions approximately 23 × 63 mm2 are required to cover one side of a large (1000 × 600 mm2) panel, which is to be mounted in front of one of two high throughput X- ray telescopes. Rocking curves of 441 LiF(220) crystals measured by using an expanded Cu - Kα2 beam were analyzed to select...... the main parameters of the rocking curve averaged over all crystals can be improved at least by a factor of 1.6 both in full width half maximum and peak reflectivity....

  20. Extended Evaluations of the Commercial Spectrometer Systems for Safeguards Applications

    Energy Technology Data Exchange (ETDEWEB)

    Duc T. Vo

    1999-08-01

    Safeguards applications require the best of the spectrometer system with excellent resolution, stability, and throughput. Instruments must perform well in all situations and environments. Data communication to the computer should be convenient, fast, and reliable. The software should have all the necessary tools and be easy to use. Portable systems should be small in size, lightweight, and have a long battery life. Nine commercially available spectrometer systems are tested with five different germanium detectors. Considering the performance of the Digital Signal Processors (DSP), digital-based spectroscope y may become the way of future gamma-ray spectroscopy.

  1. Computers in activation analysis and gamma-ray spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Carpenter, B. S.; D' Agostino, M. D.; Yule, H. P. [eds.

    1979-01-01

    Seventy-three papers are included under the following session headings: analytical and mathematical methods for data analysis; software systems for ..gamma..-ray and x-ray spectrometry; ..gamma..-ray spectra treatment, peak evaluation; least squares; IAEA intercomparison of methods for processing spectra; computer and calculator utilization in spectrometer systems; and applications in safeguards, fuel scanning, and environmental monitoring. Separate abstracts were prepared for 72 of those papers. (DLC)

  2. The development of a spectrometer for 14 MeV neutrons from fusion

    International Nuclear Information System (INIS)

    Aronsson, D.

    1991-01-01

    A spectrometer for 14 MeV neutrons, to be used for fusion plasma diagnostics at JET, was developed. The spectrometer utilizes neutron scattering in a polyethylene foil with the detection of the scattered neutron and its associated recoil proton. For the detection of 12 MeV protons we have tested silicon surface barrier detectors, lithium-drifted silicon detectors and high purity germanium detectors. The lithium-drifted detectors were finally selected for use in the spectrometer. The lithium-drifted silicon diodes have also been used for direct spectrometry, utilizing the neutron induced charged particle reactions in silicon. The methods used for the energy calibration and the timing calibration of the diodes, both during the installation of the spectrometer and during operation, are described. The detection of 2 MeV neutrons is done by fast plastic scintillators. Since the neutron generator which was used to test the detectors supplies 14 MeV or 2.5 MeV neutrons only, a neutron energy converter has to be constructed to study the detectors at other neutron energies. In the actual spectrometer an array of scintillation neutron detectors is used. A method of calibrating such an array of detectors with a gamma source was elaborated and is also described here. The result of the calibration is a set of parameters than can be used to determine the high voltage settings and the discriminator levels that are needed to achieve homogeneous sensitivity for all the detectors of the array. The energy scale itself was then calibrated by using gamma sources of various energies. To test the spectrometer as a whole at a neutron generator, a test bed was constructed. A lithium-drifted silicon diode was used to measure the neutron flux and the neutron energy resolution in the test bed. (au)

  3. Design and environmental applications of an ultra-low-background, high-efficiency intrinsic Ge gamma-ray spectrometer

    International Nuclear Information System (INIS)

    Wogman, N.A.

    1981-04-01

    A coincidence shielded intrinsic Ge gamma-ray spectrometer incorporating a 25% efficient, high resolution coaxial diode inside a 30 cm diameter NaI(Tl) shield is described. System design eliminates the major cause of background and minimizes cosmic-ray created background events through the use of electronic means. The system provides a peak-to-Compton ratio of greater than 1000 to 1 for 137 Cs and high sensitivity for both low and high level radionuclide measurements. At 3 MeV the background is 0.000058 counts per minute per keV. At 1 MeV it is 0.00048 counts per minute per keV, and at 0.5 MeV it is 0.0045 counts per minute per keV. Traces of primordial radionuclides create background events such as at 2.614 MeV (0.016 counts per minute total peak area), at 2.448 MeV (0.0058 counts per minute per total peak area), and at 2.204 MeV (0.023 counts per minute per total peak area). The system is discussed with respect to its background design, methods to improve its design, and its application to measurements of neutron activated and environmental materials problems

  4. Spectral analysis and compositing techniques for the Near Earth Asteroid Rendezvous (NEAR Shoemaker), X-ray and Gamma-Ray Spectrometers (XGRS)

    CERN Document Server

    McClanahan, T P; Nittler, L R; Boynton, W V; Bruckner, J; Squyres, S W; Evans, L G; Bhangoo, J S; Clark, P E; Floyd, S R; McCartney, E; Mikheeva, I; Starr, R D

    2001-01-01

    An X-ray and Gamma-Ray Spectrometer (XGRS) is on board the Near Earth Asteroid Rendezvous (NEAR) spacecraft to determine the elemental composition of the surface of the asteroid 433 Eros. The Eros asteroid is highly oblate and irregular in shape. As a result, analysis methodologies are in many ways a divergence from comparable techniques. Complex temporal, spatial and instrument performance relationships must be accounted for during the analysis process. Field of view and asteroid surface geometry measurements must be modeled and then combined with real measurements of solar, spectral and instrument calibration information to derive scientific results. NEAR is currently orbiting 433 Eros and is in the initial phases of its primary data integration and mapping phases. Initial results have been obtained and bulk chemistry assessments have been obtained through specialized background assessment and data reduction techniques.

  5. Microprocessor based data acquisition system for Moessbauer spectrometer

    International Nuclear Information System (INIS)

    Patwardhan, P.K.; Indurkar, V.S.

    1981-01-01

    A data acquisition system, for Moessbauer spectrometer and other probability distribution spectrum is described. This utilizes the advantages of incorporating a microcomputer for providing a flexible analytical capability and speed of hard wired MCS unit updating channel contents in DMA. Holbourn, Player and Woodhams have recently described a microprocessor controlled Moessbauer spectrometer where microprocessor performs the task of updating channel contents, requiring about 60 micro seconds in interrupt mode. This imposes restrictions on increasing the channel number and on increasing the velocity scan frequency in order to cover higher velocity ranges. The system described in this article performs data acquisition in faster direct memory access. It is a two module system, (1) MCS module (2) Microcomputer module, arranged around a common address, data and control buses. The microcomputer module has an access to the system data during flyback periods and can be programmed for the task of monitor on progess of experiment and as a manipulator of various control operations needed during experiment. The system firmware includes: (1) MONITOR (2) BLOCK-TRANSFER (3) DATA-SMOOTHING (4) DECIMAL-CONVERTER (5) MATH. The scope of this firmware is briefly described. (author)

  6. A dual purpose Compton suppression spectrometer

    CERN Document Server

    Parus, J; Raab, W; Donohue, D

    2003-01-01

    A gamma-ray spectrometer with a passive and an active shield is described. It consists of a HPGe coaxial detector of 42% efficiency and 4 NaI(Tl) detectors. The energy output pulses of the Ge detector are delivered into the 3 spectrometry chains giving the normal, anti- and coincidence spectra. From the spectra of a number of sup 1 sup 3 sup 7 Cs and sup 6 sup 0 Co sources a Compton suppression factor, SF and a Compton reduction factor, RF, as the parameters characterizing the system performance, were calculated as a function of energy and source activity and compared with those given in literature. The natural background is reduced about 8 times in the anticoincidence mode of operation, compared to the normal spectrum which results in decreasing the detection limits for non-coincident gamma-rays up to a factor of 3. In the presence of other gamma-ray activities, in the range from 5 to 11 kBq, non- and coincident, the detection limits can be decreased for some nuclides by a factor of 3 to 5.7.

  7. ALICE photon spectrometer crystals

    CERN Multimedia

    Maximilien Brice

    2006-01-01

    Members of the mechanical assembly team insert the last few crystals into the first module of ALICE's photon spectrometer. These crystals are made from lead-tungstate, a crystal as clear as glass but with nearly four times the density. When a high-energy particle passes through one of these crystals it will scintillate, emitting a flash of light allowing the energy of photons, electrons and positrons to be measured.

  8. Direction-Sensitive Hand-Held Gamma-Ray Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Mukhopadhyay, S.

    2012-10-04

    A novel, light-weight, hand-held gamma-ray detector with directional sensitivity is being designed. The detector uses a set of multiple rings around two cylindrical surfaces, which provides precise location of two interaction points on two concentric cylindrical planes, wherefrom the source location can be traced back by back projection and/or Compton imaging technique. The detectors are 2.0 × 2.0 mm europium-doped strontium iodide (SrI2:Eu2+) crystals, whose light output has been measured to exceed 120,000 photons/MeV, making it one of the brightest scintillators in existence. The crystal’s energy resolution, less than 3% at 662 keV, is also excellent, and the response is highly linear over a wide range of gamma-ray energies. The emission of SrI2:Eu2+ is well matched to both photo-multiplier tubes and blue-enhanced silicon photodiodes. The solid-state photomultipliers used in this design (each 2.0 × 2.0 mm) are arrays of active pixel sensors (avalanche photodiodes driven beyond their breakdown voltage in reverse bias); each pixel acts as a binary photon detector, and their summed output is an analog representation of the total photon energy, while the individual pixel accurately defines the point of interaction. A simple back-projection algorithm involving cone-surface mapping is being modeled. The back projection for an event cone is a conical surface defining the possible location of the source. The cone axis is the straight line passing through the first and second interaction points.

  9. Physical principles of neutron-gamma materials monitoring

    Science.gov (United States)

    Pekarskii, G. Sh.

    1986-03-01

    The physical principles of secondary radiation methods in nondestructive testing are discussed. Among the techniques considered are: neutron activation analysis (NAA); the induced-radiation method; and quasialbedo recording of secondary gamma-radiation. Emphasis is given to the neutron-gamma method which consists of exposing test material to a neutron flux and recording the secondary gamma-radiation by means of a spectrometer. The limitations of the method in detecting local inhomogeneous defects (filled pores cracks, and inclusions) in metal layers and multicomponents materials are described, and some advantages of the method over NAA are discussed. Formulas are derived for estimating the optimum density of the gamma-ray flux which is received by the detector.

  10. A neutron time of flight spectrometer appropriate for D-T plasma diagnostics

    International Nuclear Information System (INIS)

    Elevant, T.

    1984-02-01

    A neutron time-of-flight spectrometer with 2 m flight path for diagnostics of deuterium plasmas in JET is presently under construction. An upgrade of this spectrometer to make it appropriate for 14-MeV neutron spectroscopy is presented here. It is suggested to use backscattering in a deuterium based scintillator. The flight path length is 1-2 m and the efficiency is of the order of 2.10 -5 cm -5 . Results from test of principle are presented with estimates for neutron and gamma backgrounds

  11. Implementation of an Imaging Spectrometer for Localization and Identification of Radioactive Sources

    International Nuclear Information System (INIS)

    Hermine, Lemaire; Carrel, Frederick; Gmar, Mehdi; Menesguen Yves; Normand, Stephane; Schoepff, Vincent; Abou-Khalil, Roger; Amgarou, Khalil; Menaa, Nabil; Tebug, Timi; Angelique, Jean-Claude; Bonnet, Florent; De-Toro, Daniel; Giarmana, Olivier; Patoz, Audrey; Talent, Philippe

    2013-06-01

    Spatial localization of radioactive sources is currently a main issue interesting nuclear industry as well as homeland security applications, and can be achieved using gamma cameras. For several years, CEA LIST has been designing a new system, called GAMPIX, with improved sensitivity, portability and ease of use. The main remaining limitation is the lack of spectrometric information, preventing radioactive materials identification. This article describes the development of an imaging spectrometer based on the GAMPIX technology. Experimental tests have been carried out according to both spectrometric methods enabled by the pixelated Timepix readout chip used in the GAMPIX gamma camera. The first method is based on the size of the impacts produced by a gamma-ray energy deposition in the detection matrix. The second one uses the Time over Threshold (ToT) mode of the Timepix chip and deals with time spent by pulses generated by charge preamplifiers over a user-specified threshold. Both energy resolution and sensitivity studies proved the superiority of the ToT approach that will consequently be further explored. Energy calibration, tests of several pixel sizes and use of the Medipix3 readout chip are tracks to improve performances of the newly implemented imaging spectrometer. (authors)

  12. Design of a Compton-suppression spectrometer and its application to the study of high-spin yrast states

    International Nuclear Information System (INIS)

    Aarts, H.J.M.

    1981-01-01

    Detailed γ-ray spectroscopy of high-spin states is hampered by transitions with low intensity on a high γ-ray background. An approach to enhance weak peaks in a spectrum in the reduction of the Compton background by means of a Compton-suppression spectrometer (CSS). Optimization of a CSS by means of Monte Carlo calculations is described. The investigation of high-spin states in the sd-shell nucleus 38 Ar with a Compton-suppression spectrometer is reported. With previously described techniques, in combination with p-γ coincidence measurements to establish an unambiguous level scheme, states up to Jsup(π) = 11 - could be identified and investigated. A gamma-gamma coincidence experiment on the nuclei 167 168 Hf is described with two Compton-suppression spectrometers. Yrast bands are followed, beyond the region of the first backbending, up to spin J = 37/2 and J = 28 for 167 Hf and 168 Hf, respectively. (Auth.)

  13. System for Gamma an X rays fluorescence spectrometric

    International Nuclear Information System (INIS)

    Alonso Abad, D.; Arista Romeu, E.; Bolanos Perez, L. and others

    1997-01-01

    A system for spectrometry of gamma or fluorescence X rays is presented. It sis composed by a Si(Li) semiconductors detector, a charge sensitive preamplifier, a high voltage power supply, a spectrometric amplifier and a monolithic 1024 channels multichannel analyzers or an IBM compatible 4096 channels add - on- card multichannel analyzer. The system can be configured as a 1024 or 4096 channels gamma or fluorescent X rays spectrometer

  14. Very high energy gamma ray astrophysics

    International Nuclear Information System (INIS)

    Lamb, R.C.; Lewis, D.A.

    1991-01-01

    The Whipple Observatory High Resolution Camera will be used in a vigorous program of observations to search for new sources of very-high-energy gamma rays. In addition, a search for antimatter using the moon-earth system as an ion spectrometer will be begun. The first phase of GRANITE, the new 37-element 11-m camera, will be concluded with first light scheduled for September, 1991. The two cameras will operate in support of the Gamma Ray Observatory mission in the winter of 1991/2

  15. Sensitivity and response time improvements in millimeter-wave spectrometers

    International Nuclear Information System (INIS)

    Kolbe, W.F.; Leskovar, B.

    1980-09-01

    A new version of a microwave spectrometer for the detection of gaseous pollutants and other atmospheric constituents is described. The spectrometer, which operates in the vicinity of 70 GHz, employs a Fabry-Perot resonator as a sample cell and uses superhetrodyne detection for high sensitivity. The spectrometer has been modified to incorporate a frequency doubler modulated at 30 MHz to permit operation with a single Gunn oscillator source. As a result, faster response time and somewhat greater sensitivity are obtained. The spectrometer is capable of detecting a minimum concentration of 1 ppM of SO 2 diluted in air with a 1 second time constant. For OCS diluted in air, the minimum detectable concentration is 800 ppB and with a 10 second time constant 300 ppB

  16. Efficiency calibration and minimum detectable activity concentration of a real-time UAV airborne sensor system with two gamma spectrometers

    International Nuclear Information System (INIS)

    Tang, Xiao-Bin; Meng, Jia; Wang, Peng; Cao, Ye; Huang, Xi; Wen, Liang-Sheng; Chen, Da

    2016-01-01

    A small-sized UAV (NH-UAV) airborne system with two gamma spectrometers (LaBr_3 detector and HPGe detector) was developed to monitor activity concentration in serious nuclear accidents, such as the Fukushima nuclear accident. The efficiency calibration and determination of minimum detectable activity concentration (MDAC) of the specific system were studied by MC simulations at different flight altitudes, different horizontal distances from the detection position to the source term center and different source term sizes. Both air and ground radiation were considered in the models. The results obtained may provide instructive suggestions for in-situ radioactivity measurements of NH-UAV. - Highlights: • A small-sized UAV airborne sensor system was developed. • Three radioactive models were chosen to simulate the Fukushima accident. • Both the air and ground radiation were considered in the models. • The efficiency calculations and MDAC values were given. • The sensor system is able to monitor in serious nuclear accidents.

  17. Magnetic field calculation of the Na-4 muon spectrometer

    International Nuclear Information System (INIS)

    Cvach, J.; Il'yushchenko, V.I.; Savin, I.A.; Vorozhtsov, S.B.

    1980-01-01

    A NA-4 muon spectrometer is described. Preliminary results of calculating a magnetic field in a toroidal magnetic detector are given. The spectrometer includes 10 similar supermodules each of which consists of 32 iron discs with 275 cm outer diameter magnetized up to saturation. Each module is an independent detector. The POISSON program is used for calculating magnetic field distribution in a toroidal spectrometer magnet. The results obtained show that a magnetic field of iron is a toroidal one and drops approximately according to the logarithmic law from 21.1 kGs on an inner magnet rig to 17.7 kGs on an outer. Magnet support gives approximately 2 % error

  18. Performance and evaluation for a single crystal gamma spectrometer in environmental laboratory

    International Nuclear Information System (INIS)

    Pan Jingquan

    1991-01-01

    The performance of a Ge(Li) spectrometer system for measuring low-level environmental γ0ray samples is presented. It has a resolution of 2 keV, and an efficiency of 30% relative to 3 by 3 inch NaI (Tl) for the 1332 keV γ-ray of 60 Co. The integral background counts of γ-ray photons is 140 ± 2 cpm in the energy range from 12 to 2000 keV. Based on applications of measuring different types of samples, it is proved that the performance of the Ge(Li) γ-spectrometer system with a 10 cm thickness lead shield, coordinating a good experimental method, will be enough for environmental sample analyses in environmental laboratory

  19. Characterization of Compton-suppressed TIGRESS detectors for high energy gamma-rays

    International Nuclear Information System (INIS)

    Kshetri, R.; Andreoiu, C.; Cross, D.S.; Galinski, N.; Ball, G.C.; Djongolov, M.; Garnsworthy, A.B.; Hackman, G.; Orce, J.N.; Pearson, C.; Triambak, S.; Williams, S.J.; Drake, T.; Smalley, D.; Svensson, C.E.

    2009-01-01

    The TRIUMF-ISAC Gamma-Ray Escape- Suppressed Spectrometer (TIGRESS) will consist of 12 large-volume, 32-fold segmented HPGe clover detectors. Each detector is shielded by a 20-fold segmented Compton suppression shield. For performing discrete gamma-ray spectroscopy of light mass nuclei with TIGRESS, we need information about full energy peak efficiency, resolution and lineshape of full energy peaks for high energy gamma-rays. However, suitable radioactive sources having decay gamma-rays of energies greater than ∼ 3.5 MeV are not easily available. So the characteristics of gamma spectrometers at energies higher than 3.5 MeV are usually determined from simulation data. Predictions from GEANT4 simulations (experimentally validated from 0.3 to 3 MeV) indicate that TIGRESS will be capable for single 10 MeV gamma-rays of absolute detection efficiency of 1.5% for backward configuration of the array. It has been observed experimentally that simulation results work well up to certain energies and might deviate at higher energies. So, it is essential to check the validity of simulation results for energies above 3.3 MeV. We have investigated the high energy performance of seven TIGRESS detectors up to 8 MeV

  20. Developments in gamma-ray spectrometry: systems, software, and methods-II. 3. Low-Energy Gamma-Ray Spectrometry Using a Compton-Suppressed Telescope Detector

    International Nuclear Information System (INIS)

    Sigg, R.A.; DiPrete, D.P.

    2001-01-01

    The Savannah River Technology Center (SRTC) utilizes gamma-ray spectrometry in studying numerous areas of applied interest to the Savannah River Site (SRS). For example, analyses of long-lived gamma-ray-emitting fission products and actinides are required to meet waste characterization, process holdup, environmental restoration, and decontamination and decommissioning efforts. A significant portion of the overall effort centers on measurements of gamma rays having energies below several hundred kilo-electron-volts. To assist these efforts, the SRTC recently acquired a spectrometer system that provides lower natural and Compton scattered background levels while achieving relatively high counting efficiencies for low-energy gamma rays. The combination of high efficiency and low background provides factor-of- 2-to-4 improvements in minimum detectable activities and allows meeting programmatic objectives with shorter measurement times. Numerous Compton-suppression spectrometers have been reported since the concept was first advanced. The spectrometer consists of two high-purity germanium detectors in a telescope configuration surrounded by a background /Compton-suppression sodium iodide detector. The front germanium detector is a 20-mm-thick x 60-mm-diam broad energy spectrometer, and the rear detector is a 40% efficient 61- mm-diam x 60-cm-thick closed-end coaxial spectrometer. The cryostat housing the germanium detectors (a) includes a carbon composite window for transmitting low-energy gamma rays, (b) is in a J-type configuration to mask the germanium detectors from natural activities in the cryo-pumping media, and (c) is fabricated from materials selected for low background. The telescope detector is in the 8.6-cm-inside-diameter annulus of a 22.9- x 22.9-cm sodium iodide detector encased in a 10-cm-thick lead shield. The counting system is located in a basement counting room having ∼60-cm-thick concrete walls. Initial tests show that the low-energy segment of

  1. Integration and evaluation of a position sensor with continuous read-out for use with the Environmental Measurement-While-Drilling Gamma Ray Spectrometer system

    International Nuclear Information System (INIS)

    Normann, R.A.; Lockwood, G.J.; Williams, C.V.; Selph, M.M.

    1998-02-01

    The Environmental Measurement-While-Drilling-Gamma Ray Spectrometer (EMWD-GRS) system represents an innovative blend of new and existing technology that provides real-time environmental and drill bit data during drilling operations. The EMWD-GRS technology was demonstrated at Savannah River Site (SRS) F-Area Retention Basin. The EMWD-GRS technology demonstration consisted of continuously monitoring for gamma-radiation-producing contamination while drilling two horizontal boreholes below the backfilled waste retention basin. These boreholes passed near previously sampled locations where concentrations of contaminant levels of cesium had been measured. Contaminant levels continuously recorded by the EMWD-GRS system during drilling were compared to contaminant levels previously determined through quantitative laboratory analysis of soil samples. The results show general agreement between the soil sampling and EMWD-GRS techniques for Cs-137. The EMWD-GRS system has been improved by the integration of an orientation sensor package for position sensing (PS) (EMWD-GRS/PS). This added feature gives the capability of calculating position, which is tied directly to EMWD-GRS sensor data obtained while drilling. The EMWD-GRS/PS system is described and the results of the field tests are presented

  2. Measurements of angular and energy distributions of gamma-rays resulting from neutron interactions in shielding barriers

    International Nuclear Information System (INIS)

    Makarious, A.S.; Maayouf, R.M.A.; Megahid, R.

    1978-01-01

    Measurements of both angular and energy distributions of secondary gamma resulting from interactions of neutrons emerging from one of the ET-RR-1 reactor beam holes, in barriers from iron, lead and water are reported. The measurements were carried out, both with a bare neutron beam and with the beam being transmitted through a B4C. Filter, using a stilbene crystal gamma spectrometer. The spectrometer applies discrimination between neutrons and gammas according to the difference in decay times of the scintillations produced by them in stilbene. The described angular distributions resulted from measurements made at different angles of neutron incidence and with three different thicknesses of each sample

  3. Inhomogeneity of neutron and gamma-ray attenuation in biological shields

    Energy Technology Data Exchange (ETDEWEB)

    El-bakkoush, F A; El-Ghobary, A M; Megahid, R M [Reactor and Neutron physics Department, Nuclear Research Center, A.E.A., Cairo (Egypt)

    1997-12-31

    Measurements have been carried-out to investigate the attenuation properties of some materials which are used as biological shields around nuclear radiation sources. Investigation was performed by measuring the transmitted fast neutron and gamma-spectra through cylindrical samples of magnetite- limonite, steel and cellulose shields. The neutron and gamma spectra were measured by a neutron-gamma spectrometer with stilbene scintillator. Discrimination between neutron and gamma pulses was achieved by a discrimination method. The obtained results are displayed in the form of neutron and gamma spectra and attenuation relations which are used to derive the total macroscopic cross-sections for neutrons and total linear attenuation coefficients for gamma-rays. The values of neutron and gamma relaxation lengths are also derived for the investigated materials. 10 figs., 1 tabs.

  4. A study of gamma-irradiated polyethylenes by temperature modulated differential scanning calorimetry

    Science.gov (United States)

    Galovic, S.; Secerov, B.; Trifunovic, S.; Milicevic, D.; Suljovrujic, E.

    2012-09-01

    Various polyethylenes (PEs) and the effects of high-energy radiation on their structures were widely studied in the past using conventional Differential Scanning Calorimetry (DSC) measurements. In this work, we used the Temperature Modulated Differential Scanning Calorimetry (TMDSC) technique in order to obtain more information about the influence of the initial structural differences and gamma radiation on the evolution in structure and thermal properties of different polyethylenes. For this reason, low density polyethylene (LDPE), linear low density polyethylene (LLDPE) and high density polyethylene (HDPE) samples were exposed to gamma radiation, in air, to a wide range of absorbed doses (up to 2400 kGy). The separation of the total heat flow TMDSC signal into a reversing and non-reversing part enabled us to observe the low-temperature enthalpy relaxation (related to the existence of the "rigid amorphous phase") and recrystallisation processes, as well as to follow their radiation-induced evolution and/or that of melting in a more revealing manner compared to the case of the conventional DSC. Consequently, our results indicate that TMDSC could improve the understanding of radiation-induced effects in polymers.

  5. Mercuric Iodide Anticoincidence Shield for Gamma-Ray Spectrometer, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to utilize a new detector material, polycrystalline mercuric iodide, for background suppression by active anticoincidence shielding in gamma-ray...

  6. Distribution of iron and titanium on the lunar surface from lunar prospector gamma ray spectra

    International Nuclear Information System (INIS)

    Prettyman, T.H.; Feldman, W.C.; Lawrence, David J.; Elphic, R.C.; Gasnault, O.M.; Maurice, S.; Moore, K.R.; Binder, A.B.

    2001-01-01

    Gamma ray pulse height spectra acquired by the Lunar Prospector (LP) Gamma-Ray Spectrometer (GRS) contain information on the abundance of major elements in the lunar surface, including O, Si, Ti, Al, Fe, Mg, Ca, K, and Th. With the exception of Th and K, prompt gamma rays produced by cosmic ray interactions with surface materials are used to determine elemental abundance. Most of these gamma rays are produced by inelastic scattering of fast neutrons and by neutron capture. The production of neutron-induced gamma rays reaches a maximum deep below the surface (e.g. ∼140 g/cm 2 for inelastic scattering and ∼50 g/cm 2 for capture). Consequently, gamma rays sense the bulk composition of lunar materials, in contrast to optical methods (e.g. Clementine Spectral Reflectance (CSR)), which only sample the top few microns. Because most of the gamma rays are produced deep beneath the surface, few escape unscattered and the continuum of scattered gamma rays dominates the spectrum. In addition, due to the resolution of the spectrometer, there are few well-isolated peaks and peak fitting algorithms must be used to deconvolve the spectrum in order to determine the contribution of individual elements.

  7. Gamma-index method sensitivity for gauging plan delivery accuracy of volumetric modulated arc therapy.

    Science.gov (United States)

    Park, Jong In; Park, Jong Min; Kim, Jung-In; Park, So-Yeon; Ye, Sung-Joon

    2015-12-01

    The aim of this study was to investigate the sensitivity of the gamma-index method according to various gamma criteria for volumetric modulated arc therapy (VMAT). Twenty head and neck (HN) and twenty prostate VMAT plans were retrospectively selected for this study. Both global and local 2D gamma evaluations were performed with criteria of 3%/3 mm, 2%/2 mm, 1%/2 mm and 2%/1 mm. In this study, the global and local gamma-index calculated the differences in doses relative to the maximum dose and the dose at the current measurement point, respectively. Using log files acquired during delivery, the differences in parameters at every control point between the VMAT plans and the log files were acquired. The differences in dose-volumetric parameters between reconstructed VMAT plans using the log files and the original VMAT plans were calculated. The Spearman's rank correlation coefficients (rs) were calculated between the passing rates and those differences. Considerable correlations with statistical significances were observed between global 1%/2 mm, local 1%/2 mm and local 2%/1 mm and the MLC position differences (rs = -0.712, -0.628 and -0.581). The numbers of rs values with statistical significance between the passing rates and the changes in dose-volumetric parameters were largest in global 2%/2 mm (n = 16), global 2%/1 mm (n = 15) and local 2%/1 mm (n = 13) criteria. Local gamma-index method with 2%/1 mm generally showed higher sensitivity to detect deviations between a VMAT plan and the delivery of the VMAT plan. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  8. A multi-parameter, acquisition system positron annihilation lifetime spectrometer

    International Nuclear Information System (INIS)

    Sharshar, T.

    2004-01-01

    A positron annihilation lifetime spectrometer employing a multi-parameter acquisition system has been prepared for various purposes such as the investigation and characterization of solid-state materials. The fast-fast coincidence technique was used in the present spectrometer with a pair of plastic scintillation detectors. The acquisition system is based on the Kmax software and on CAMAC modules. The data are acquired in event-by-event list mode. The time spectrum for the desired energy windows can be obtained by off-line data sorting and analysis. The spectrometer for event-by-event data acquisition is an important step to construct a positron age-momentum correlation (AMOC) spectrometer. The AMOC technique is especially suited for the observation of positron transitions between different states during their lifetime. The system performance was tested and the results were presented and discussed

  9. Gamma and Xray spectroscopy at high performance

    International Nuclear Information System (INIS)

    Borchert, G.L.

    1984-01-01

    The author determines that for many interesting problems in gamma and Xray spectroscopy it is necessary to use crystal diffractometers. The basic features of such instruments are discussed and the special performance of crystal spectrometers is demonstrated by means of typical examples of various applications

  10. Airborne gamma-ray spectrometer and magnetometer survey: Lund quadrangle, Ely quadrangle, Nevada. Volume I. Final report

    International Nuclear Information System (INIS)

    1980-01-01

    An airborne combined radiometric and magnetic survey was performed for the Department of Energy (DOE) over the area covered by the Ely and Lund 1:250,000 National Topographic Map Series (NTMS quadrangle maps). The survey was part of DOE's National Uranium Resource Evaluation (NURE) Aerial Radiometric Reconnaissance program. Data were collected by a helicopter equipped with a gamma-ray spectrometer having a large crystal volume, and a high sensitivity proton precession magnetometer. The radiometric system was calibrated at the Walker Field Calibration pads and the Lake Mead Dynamic Test range. Data quality was ensured during the survey by daily test flights and equipment checks. Radiometric data were corrected for live time, aircraft and equipment background, cosmic background, atmospheric radon, Compton scatter, and altitude dependence. The corrected data were statistically evaluated, plotted, and contoured to produce anomaly maps based on the radiometric response of individual geological units. The maps were interpreted and an anomaly interpretation map produced. Volume I contains a description of the systems used in the survey, a discussion of the calibration of the systems, the data processing procedures, the data display format, the interpretation rationale, and interpretation methodology. Volume II contains the data displays for a quadrangle and the interpretation results

  11. Characterisation of neutron beam and gamma spectrometer for PGAA

    International Nuclear Information System (INIS)

    Revay, Zs.; Molnar, G.L.

    2001-01-01

    In the second project year great efforts have been devoted in Budapest to the development of methods and procedures for neutron beam characterisation and spectrometer calibration. These are described here to provide recipes for other laboratories. Some illustrative results obtained on the former thermal guide, and partly on the new cold neutron guide are also given. Preliminary results from the benchmark experiments on flux monitors titanium standard and an unknown sample are also reported. New k o factors for elements of highest priority will be measured on the cold beam only in the near future. (author)

  12. Aircraft gamma-ray spectrometry in snow-water equivalent measurement

    International Nuclear Information System (INIS)

    Kuittinen, R.; Vironmaeki, J.

    1979-01-01

    During the winter periods 1976-1977 and 1977-1978 the Hydrological Office at the National Board of Waters and the Geological Survey of Finland carried out a joint study to evaluate usefuluess of gamma-ray spectrometry in snow-water equivalent measurement. A multichannel gamma-ray spectrometer was fitted in a DC-3 aircraft. Fourteen snow courses were operated using both the gravimetric method and the gamma-ray method. The snow courses were located in southern Finland in forest, swamp and agricultural land. The results shows that the gamma ray method can be considered suitable for use in Finnish conditions and the accuracy of the gamma-ray method is almost of the same magnitude as the accuracy of the gravimetric method. (Auth.)

  13. Aircraft gamma-ray spectrometry in snow-water equivalent measurement

    Energy Technology Data Exchange (ETDEWEB)

    Kuittinen, R [National Board of Waters (Finland); Vironmaeki, J [Geological Survey of Finland

    1979-01-01

    During the winter periods 1976-1977 and 1977-1978 the Hydrological Office at the National Board of Waters and the Geological Survey of Finland carried out a joint study to evaluate usefuluess of gamma-ray spectrometry in snow-water equivalent measurement. A multichannel gamma-ray spectrometer was fitted in a DC-3 aircraft. Fourteen snow courses were operated using both the gravimetric method and the gamma-ray method. The snow courses were located in southern Finland in forest, swamp and agricultural land. The results shows that the gamma ray method can be considered suitable for use in Finnish conditions and the accuracy of the gamma-ray method is almost of the same magnitude as the accuracy of the gravimetric method.

  14. A cadmium-zinc-telluride crystal array spectrometer

    International Nuclear Information System (INIS)

    McHugh, H. R.; Quam, W.; DeVore, T.; Vogle, R.; Weslowski, J.

    2003-01-01

    This paper describes a gamma detector employing an array of eight cadmium-zinc-telluride (CZT) crystals configured as a high resolution gamma ray spectrometer. This detector is part of a more complex instrument that identifies the isotope,displays this information, and records the gamma spectrum. Various alarms and other operator features are incorporated in this battery operated rugged instrument. The CZT detector is the key component of this instrument and will be described in detail in this paper. We have made extensive spectral measurements of the usual laboratory gamma sources, common medical isotopes, and various Special Nuclear Materials (SNM) with this detector. Some of these data will be presented as spectra. We will also present energy resolution and detection efficiency for the basic 8-crystal array. Additional data will also be presented for a 32-crystal array. The basic 8-crystal array development was completed two years ago, and the system electronic design has been imp roved recently. This has resulted in significantly improved noise performance. We expect to have a much smaller detector package, using 8 crystals, in a few months. This package will use flip-chip packaging to reduce the electronics physical size by a factor of 5

  15. Beta-spectrometer with Si-detectors for the study of 144Ce-144Pr decays

    Science.gov (United States)

    Alexeev, I. E.; Bakhlanov, S. V.; Bazlov, N. V.; Chmel, E. A.; Derbin, A. V.; Drachnev, I. S.; Kotina, I. M.; Muratova, V. N.; Pilipenko, N. V.; Semyonov, D. A.; Unzhakov, E. V.; Yeremin, V. K.

    2018-05-01

    Here we present the specifications of a newly developed beta-spectrometer, based on full absorption Si(Li) detector and thin transmission detector, allowing one to perform efficient separation beta-radiation and accompanying X-rays and gamma radiation. Our method is based on registration of coincident events from both detectors. The spectrometer can be used for precision measurements of various beta-spectra, namely for the beta-spectrum shape study of 144Pr, which is considered to be an advantageous anti-neutrino source for sterile neutrino searches.

  16. Recent results on celestial gamma radiation from SMM

    Science.gov (United States)

    Share, Gerald H.

    1991-01-01

    Observations made by the Gamma Ray Spectrometer on board the SMM are described. Recent results reported include observations and analyses of gamma-ray lines from Co-56 produced in supernovae, observations of the temporal variation of the 511 keV line observed during Galactic center transits, and measurements of the diffuse Galactic spectrum from 0.3 to 8.5 MeV. The work in progress includes measurements of the distribution of Galactic Al-26, observations to place limits on Galactic Ti-44 and Fe-60 and on Be-7 produced in novae, and searches for a characteristic gamma-ray emission from pair plasmas, a 2.223 MeV line emission, limits on deexcitation lines from interstellar C and O, and gamma-ray bursts.

  17. Evaluation of TASTEX task H: measurement of plutonium isotopic abundances by gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Gunnink, R.; Prindle, A.L.; Asakura, Y.; Masui, J.; Ishiguro, N.; Kawasaki, A.; Kataoka, S.

    1981-10-01

    This report describes a computer-based gamma spectrometer system that was developed for measuring isotopic and total plutonium concentrations in nitric acid solutions. The system was installed at the Tokai reprocessing plant where it is undergoing testing and evaluation as part of the Tokai Advanced Safeguards Exercise (TASTEX). Objectives of TASTEX Task H, High-Resolution Gamma Spectrometer for Plutonium Isotopic Analysis, the methods and equipment used, the installation and calibration of the system, and the measurements obtained from several reprocessing campaigns are discussed and described. In general, we find that measurements for gamma spectroscopy agree well with those of mass spectrometry and of other chemical analysis. The system measures both freshly processed plutonium from the product accountability tank and aged plutonium solutions from storage tanks. 14 figures, 15 tables

  18. Recording {gamma} spectrometer with elimination of compton background; Spectrographe {gamma} enregistreur avec elimination du bruit de fond compton

    Energy Technology Data Exchange (ETDEWEB)

    Julliot, C [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    This instrument, derived from the recording {gamma} spectrograph, gives better definition of photoelectric peaks by elimination of pulses caused by {gamma} photons incompletely absorbed in the scintillator (Compton effect). This system uses an original method devised by Peirson: the spectrum, devoid of photoelectric peak, supplied by a detector equipped with an anthracene scintillator, is cut off from the spectrum provided by a conventional detector equipped with a Nal (T1) scintillator. The regulation of the mechanical system, detector support and source allows the detection yields to be adjusted. The electronic system is identical in presentation with that of the recording spectrograph. (author) [French] Cet appareil derive du spectrographe {gamma} enregistreur permet d'obtenir une meilleure definition des pics photoelectriques, par elimination des impulsions provenant des photons {gamma} incompletement absorbes dans le scintillateur (effet Compton). Cet ensemble met en oeuvre une methode originale due a Peirson: le spectre, depourvu de pic photoelectrique, fourni par un detecteur, equipe avec un scintillateur d'anthracene, est retranche du spectre donne par un detecteur classique, equipe avec un scintillateur de NaI (T1). Le reglage de l'ensemble mecanique, support des detecteurs et de la source, permet d'ajuster les rendements de detection. L'ensemble electronique se presente sous un aspect identique a celui du spectrographe enregistreur. (auteur)

  19. γ-Ray background sources in the VESUVIO spectrometer at ISIS spallation neutron source

    International Nuclear Information System (INIS)

    Pietropaolo, A.; Perelli Cippo, E.; Gorini, G.; Tardocchi, M.; Schooneveld, E.M.; Andreani, C.; Senesi, R.

    2009-01-01

    An investigation of the gamma background was carried out in the VESUVIO spectrometer at the ISIS spallation neutron source. This study, performed with a yttrium-aluminum-perovskite (YAP) scintillator, follows high resolution pulse height measurements of the gamma background carried out on the same instrument with the use of a high-purity germanium detector. In this experimental work, a mapping of the gamma background was attempted, trying to find the spatial distribution and degree of directionality of the different contributions identified in the previous study. It is found that the gamma background at low times is highly directional and mostly due to the gamma rays generated in the moderator-decoupler system. The other contributions, consistently to the findings of a previous experiment, are identified as a nearly isotropic one due to neutron absorption in the walls of the experimental hall, and a directional one coming from the beam dump.

  20. γ-Ray background sources in the VESUVIO spectrometer at ISIS spallation neutron source

    Science.gov (United States)

    Pietropaolo, A.; Perelli Cippo, E.; Gorini, G.; Tardocchi, M.; Schooneveld, E. M.; Andreani, C.; Senesi, R.

    2009-09-01

    An investigation of the gamma background was carried out in the VESUVIO spectrometer at the ISIS spallation neutron source. This study, performed with a yttrium-aluminum-perovskite (YAP) scintillator, follows high resolution pulse height measurements of the gamma background carried out on the same instrument with the use of a high-purity germanium detector. In this experimental work, a mapping of the gamma background was attempted, trying to find the spatial distribution and degree of directionality of the different contributions identified in the previous study. It is found that the gamma background at low times is highly directional and mostly due to the gamma rays generated in the moderator-decoupler system. The other contributions, consistently to the findings of a previous experiment, are identified as a nearly isotropic one due to neutron absorption in the walls of the experimental hall, and a directional one coming from the beam dump.

  1. Autonomous long-term gamma-spectrometric monitoring of submarine groundwater discharge trends in Hawaii

    International Nuclear Information System (INIS)

    Dulai, Henrietta; Waters, Ch.A.; Kennedy, Joseph; Kamenik, Jan; Academy of Sciences of the Czech Republic, Rez; Babinec, James; Jolly, James; Williamson, Mario

    2016-01-01

    We developed a fully autonomous underwater gamma-spectrometer for long-term coastal submarine groundwater discharge (SGD) monitoring. The instrument represents a significant improvement over previous submarine gamma-spectrometers in that it is very robust, has high sensitivity allowing high temporal resolution, and is completely autonomous. Here we describe the technical parameters of the new instrument as well as data collected over its 9-month deployment in Kiholo Bay, HI, USA. We also present methods to convert the measured activities to SGD rates. In Kiholo Bay, the derived SGD matched previous estimates but in addition it revealed previously undocumented short- and long-term patterns in SGD. (author)

  2. The sample of INTEGRAL SPI-ACS gamma-ray bursts

    International Nuclear Information System (INIS)

    Rau, A.; Kienlin, A. von; Licht, G.G.; Hurley, K.

    2005-01-01

    The anti-coincidence system of the spectrometer on board INTEGRAL is operated as a nearly omni directional gamma-ray burst detector above ∼ 75 KeV. During the elapsed mission time 324 burst candidates were detected. As part of the 3rd Interplanetary Network of gamma-ray detectors the cosmic origin of 115 burst was confirmed. Here we present a preliminary analysis of the SPI-ACS gamma-ray burst sample. In particular we discuss the origin of a significant population of short events (duration < 0.2 s) and a possible method for a flux calibration of the data

  3. Calibrated infrared ground/air radiometric spectrometer

    Science.gov (United States)

    Silk, J. K.; Schildkraut, Elliot Robert; Bauldree, Russell S.; Goodrich, Shawn M.

    1996-06-01

    The calibrated infrared ground/air radiometric spectrometer (CIGARS) is a new high performance, multi-purpose, multi- platform Fourier transform spectrometer (FPS) sensor. It covers the waveband from 0.2 to 12 micrometer, has spectral resolution as fine as 0.3 cm-1, and records over 100 spectra per second. Two CIGARS units are being used for observations of target signatures in the air or on the ground from fixed or moving platforms, including high performance jet aircraft. In this paper we describe the characteristics and capabilities of the CIGARS sensor, which uses four interchangeable detector modules (Si, InGaAs, InSb, and HgCdTe) and two optics modules, with internal calibration. The data recording electronics support observations of transient events, even without precise information on the timing of the event. We present test and calibration data on the sensitivity, spectral resolution, stability, and spectral rate of CIGARS, and examples of in- flight observations of real targets. We also discuss plans for adapting CIGARS for imaging spectroscopy observations, with simultaneous spectral and spatial data, by replacing the existing detectors with a focal plane array (FPA).

  4. GIOVE, a shallow laboratory Ge-spectrometer with 100 μBq/kg sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Heusser, G.; Weber, M.; Denz, T.; Hakenmueller, J.; Hofacker, R.; Lackner, R.; Lindner, M.; Maneschg, W.; Reisfelder, M.; Simgen, H.; Schreiner, J.; Stolzenburg, D.; Strecker, H.; Westermann, J. [Max-Planck-Institut fuer Kernphysik, Saupfercheckweg 1, D-69117 Heidelberg (Germany)

    2013-08-08

    A new germanium gamma spectrometer called GIOVE (Germanium spectrometer with Inner and Outer Veto) has been set up at the underground/shallow laboratory (15 m w.e.) of MPI-K. Its double plastic scintillator veto system and neutron moderation interlayer lower the background by more than one order of magnitude compared to the other existing spectrometer at this facility. The integral (40-2700 keV) background rate of about 290 counts (day kg){sup −1} is just a factor 4 to 8 above that of the GeMPI spectrometers operated at LNGS (3800 m w.e.) and thus proves that even under shallow overburden sub mBq/kg sensitivities are achievable. Extended material screening and neutron attenuation studies preceded the final design of the spectrometer. The technical realization of the spectrometer is described in detail with special emphasis on the inner veto system. For its optimisation a simulation model was developed for light collection on small low activity PMT’s under various geometrical conditions. Radon suppression is accomplished by employing a gas tight sample container and a nitrogen flushed glove-box system with an airlock. The active volume of the crystal was modelled by absorption scanning measurements and Monte Carlo simulations. The complete shield is implemented in a Geant4 based simulation framework.

  5. Background reduction of the KATRIN spectrometers. Transmission function of the pre-spectrometer and systematic tests of the main-spectrometer wire electrode

    Energy Technology Data Exchange (ETDEWEB)

    Prall, Matthias

    2011-07-04

    The KArlsruhe TRItium Neutrino experiment, KATRIN will determine the mass of the anti {nu}{sub e} with a sensitivity of 0.2 eV (90% C.L.) via a measurement of the {beta}-spectrum of tritium decaying in a windowless gaseous molecular tritium source near its endpoint of 18.57 keV. This approach relies exclusively on the relativistic kinematics of the decay products rendering the experiment model independent and reducing the systematic uncertainty. An ultra-low background of a few mHz and an energy resolution of 0.93 eV are among the requirements to reach the sensitivity. These demands are fulfilled with the main spectrometer (MS). While the {beta}-decay electrons are guided by a magnetic field through the experiment, the MS acts as a high-pass filter for the {beta}-decay electrons. Only those above an energy barrier, the retarding potential, are transmitted to the detector. The last about 30 eV of the T{sub 2} {beta}-spectrum will be scanned in this way. The MS is equipped with a 650 m{sup 2}, two-layered, UHV compatible and quasi-massless wire electrode suppressing secondary electron background originating at the main-spectrometer walls and caused by residual radioactivity and cosmic muons. Its energy resolution of 0.93 eV is only achieved, if a large part of the 248 wire electrode modules, which determine the electric field inside the MS, has a mechanical precision of 0.2 mm. Not a single of the about 28.000 wires of the electrode must break during the lifetime of KATRIN. A 2-dimensional laser sensor for contact-less position (precision about 0.01 mm) and tension (precision about 0.04 N) measurements was developed and applied, to firstly, verify the mechanical precision of the electrode modules and secondly, to examine their reliability. A 3-dimensional coordinate measurement table was automated to perform these measurements in a clean room. This table was also used to verify the precision of components using a camera system and image recognition methods (0.05 mm

  6. Modulation of alpha and gamma oscillations related to retrospectively orienting attention within working memory.

    Science.gov (United States)

    Poch, Claudia; Campo, Pablo; Barnes, Gareth R

    2014-07-01

    Selective attention mechanisms allow us to focus on information that is relevant to the current behavior and, equally important, ignore irrelevant information. An influential model proposes that oscillatory neural activity in the alpha band serves as an active functional inhibitory mechanism. Recent studies have shown that, in the same way that attention can be selectively oriented to bias sensory processing in favor of relevant stimuli in perceptual tasks, it is also possible to retrospectively orient attention to internal representations held in working memory. However, these studies have not explored the associated oscillatory phenomena. In the current study, we analysed the patterns of neural oscillatory activity recorded with magnetoencephalography while participants performed a change detection task, in which a spatial retro-cue was presented during the maintenance period, indicating which item or items were relevant for subsequent retrieval. Participants benefited from retro-cues in terms of accuracy and reaction time. Retro-cues also modulated oscillatory activity in the alpha and gamma frequency bands. We observed greater alpha activity in a ventral visual region ipsilateral to the attended hemifield, thus supporting its suppressive role, i.e., a functional disengagement of task-irrelevant regions. Accompanying this modulation, we found an increase in gamma activity contralateral to the attended hemifield, which could reflect attentional orienting and selective processing. These findings suggest that the oscillatory mechanisms underlying attentional orienting to representations held in working memory are similar to those engaged when attention is oriented in the perceptual space. © 2014 The Authors. European Journal of Neuroscience published by Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  7. A small diameter, flexible, all attitude, self-contained germanium spectrometer. Operator's manual

    International Nuclear Information System (INIS)

    Bordzindki, R.L.; Lepel, E.A.; Reeves, J.H.; Kohli, R.

    1997-05-01

    The end of the Cold War has brought about tremendous changes in the nuclear complex of the Department of Energy. One of the many changes has been the shutdown or decommissioning of many facilities that performed nuclear work. One of the steps in the process of decommissioning a facility involves the decontamination or removal of drain lines or pipes that may have carried radioactive materials at one time. The removal of all these pipes and drain lines to a nuclear disposal facility could be quite costly. It was suggested by Pacific Northwest National Laboratory (PNNL) that a germanium spectrometer could be built that could fit through straight pipes with a diameter as small as 5.08 cm (2 inches) and pass through curved pipes with a diameter as small as 7.6 cm (3 inches) such as that of a 3-inch p-trap in a drain line. The germanium spectrometer could then be used to simultaneously determine all gamma-ray emitting radionuclides in or surrounding the pipe. By showing the absence of any gamma-ray emitting radionuclides, the pipes could then be reused in place or disposed of as non-radioactive material, thus saving significantly in disposal costs. A germanium spectrometer system has been designed by PNNL and fabricated by Princeton Gamma Tech (PGT) that consists of three segments, each 4.84 cm in diameter and about 10 cm in length. Flexible stainless steel bellows were used to connect the segments. Segment 1 is a small liquid nitrogen reservoir. The reservoir is filled with a sponge-like material which enables the detector to be used in any orientation. A Stirling cycle refrigerator is under development which can replace the liquid nitrogen reservoir to provide continuous cooling and operation

  8. Use of UAV-Borne Spectrometer for Land Cover Classification

    Directory of Open Access Journals (Sweden)

    Sowmya Natesan

    2018-04-01

    Full Text Available Unmanned aerial vehicles (UAV are being used for low altitude remote sensing for thematic land classification using visible light and multi-spectral sensors. The objective of this work was to investigate the use of UAV equipped with a compact spectrometer for land cover classification. The UAV platform used was a DJI Flamewheel F550 hexacopter equipped with GPS and Inertial Measurement Unit (IMU navigation sensors, and a Raspberry Pi processor and camera module. The spectrometer used was the FLAME-NIR, a near-infrared spectrometer for hyperspectral measurements. RGB images and spectrometer data were captured simultaneously. As spectrometer data do not provide continuous terrain coverage, the locations of their ground elliptical footprints were determined from the bundle adjustment solution of the captured images. For each of the spectrometer ground ellipses, the land cover signature at the footprint location was determined to enable the characterization, identification, and classification of land cover elements. To attain a continuous land cover classification map, spatial interpolation was carried out from the irregularly distributed labeled spectrometer points. The accuracy of the classification was assessed using spatial intersection with the object-based image classification performed using the RGB images. Results show that in homogeneous land cover, like water, the accuracy of classification is 78% and in mixed classes, like grass, trees and manmade features, the average accuracy is 50%, thus, indicating the contribution of hyperspectral measurements of low altitude UAV-borne spectrometers to improve land cover classification.

  9. The ALICE Dimuon Spectrometer High Level Trigger

    CERN Document Server

    Becker, B; Cicalo, Corrado; Das, Indranil; de Vaux, Gareth; Fearick, Roger; Lindenstruth, Volker; Marras, Davide; Sanyal, Abhijit; Siddhanta, Sabyasachi; Staley, Florent; Steinbeck, Timm; Szostak, Artur; Usai, Gianluca; Vilakazi, Zeblon

    2009-01-01

    The ALICE Dimuon Spectrometer High Level Trigger (dHLT) is an on-line processing stage whose primary function is to select interesting events that contain distinct physics signals from heavy resonance decays such as J/psi and Gamma particles, amidst unwanted background events. It forms part of the High Level Trigger of the ALICE experiment, whose goal is to reduce the large data rate of about 25 GB/s from the ALICE detectors by an order of magnitude, without loosing interesting physics events. The dHLT has been implemented as a software trigger within a high performance and fault tolerant data transportation framework, which is run on a large cluster of commodity compute nodes. To reach the required processing speeds, the system is built as a concurrent system with a hierarchy of processing steps. The main algorithms perform partial event reconstruction, starting with hit reconstruction on the level of the raw data received from the spectrometer. Then a tracking algorithm finds track candidates from the recon...

  10. Implementation and application of the gaussian decomposition software for NaI gamma-ray spectrometry data

    International Nuclear Information System (INIS)

    Zeng Lihui; Wang Nanping; Tian Gui

    2012-01-01

    In order to extract the information of peaks in different energy from the data of overlapping peaks in environmental gamma spectrometer, a spectrum data Gaussian decomposition software was designed based on least-square Gaussian fitting method. The interface of this software is friendly, it can complete the decomposition of overlapping peaks in gamma spectrometer quickly by the way of man-machines interactive. The result of field measured data decomposed by this software indicates that the Gaussian decomposition software can efficiently extract 137 Cs spectra from over lapping peaks, which has significance to estimate the human nuclide contamination in the environment. (authors)

  11. Sensitivity of LDEF foil analyses using ultra-low background germanium vs. large NaI(Tl) multidimensional spectrometers

    International Nuclear Information System (INIS)

    Reeves, J.H.; Arthur, R.J.; Brodzinski, R.L.

    1992-06-01

    Cobalt foils and stainless steel samples were analyzed for induced 6O Co activity with both an ultra-low background germanium gamma-ray spectrometer and with a large NaI(Tl) multidimensional spectrometer, both of which use electronic anticoincidence shielding to reduce background counts resulting from cosmic rays. Aluminum samples were analyzed for 22 Na. The results, in addition to the relative sensitivities and precisions afforded by the two methods, are presented

  12. Airborne gamma-ray spectrometer and magnetometer survey: Norton Bay Quadrangle (Alaska). Final report

    International Nuclear Information System (INIS)

    1980-01-01

    During the months of July, August, and September 1979, an airborne high sensitivity gamma-ray spectrometer and magnetometer survey was conducted over ten 3 0 x 1 0 NTMS quadrangles of West-Central Alaska. The results obtained over the Norton Bay Map area are discussed. The final data are presented in four different forms: on magnetic tape; on microfiche; in graphic form as profiles and histograms; and in map form as anomaly maps and flight path maps. The histograms and the multiparameter are presented with the anomaly maps and flight path map in a separate volume. A total of twenty (20) uranium anomalies have been indicated on the interpretation map. No thorium anomalies were found. The uranium anomalies are all weak and generally have only U/K or U/T expression. Often the uranium concentration within the zone is low, and generally is less than 2.5 ppM. Only zones 9, with an average of 3.0 ppM eU, and 14, with 2.6 ppm have above average uranium content. Zone 14 is also the only uranium anomaly with combined U/K and U/T ratio anomalies. No single uranium anomaly is believed to represent an economic follow-up target. The most prospective area appears to be the elongate zone of generally high uranium content, formed by the deposits of the Shaktolik group, to the east of the Ungalik conglomerate. This zone flanks an elongate area of relatively strong shallow magnetic sources, interpreted to be related to a monozonitic intrusive of which the Christmas mountain forms part. This intrusive rock contains in other neighboring areas often high thorium and uranium concentrations and may here as well served as a possible source of uranium deposits

  13. Rapid monitoring of gaseous fission products in BWRs using a portable spectrometer

    International Nuclear Information System (INIS)

    Yeh, Wei-Wen; Lee, Cheng-Jong; Chen, Chen-Yi; Chung, Chien

    1996-01-01

    Rapid, quantitative determination of gaseous radionuclides is the most difficult task in the field of environmental monitoring for radiation. Although the identification of each gaseous radionuclide is relatively straightforward using its decayed gamma ray as an index, the quantitative measurement is hampered by the time-consuming sample collection procedures, in particular for the radioactive noble gaseous fission products of krypton and xenon. In this work, a field gamma-ray spectrometer consisting of a high-purity germanium detector, portable multichannel anlayzer, and a notebook computer was used to conduct rapid scanning of radioactive krypton and xenon in the air around a nuclear facility

  14. Foil cycling technique for the VESUVIO spectrometer operating in the resonance detector configuration

    International Nuclear Information System (INIS)

    Schooneveld, E. M.; Mayers, J.; Rhodes, N. J.; Pietropaolo, A.; Andreani, C.; Senesi, R.; Gorini, G.; Perelli-Cippo, E.; Tardocchi, M.

    2006-01-01

    This article reports a novel experimental technique, namely, the foil cycling technique, developed on the VESUVIO spectrometer (ISIS spallation source) operating in the resonance detector configuration. It is shown that with a proper use of two foils of the same neutron absorbing material it is possible, in a double energy analysis process, to narrow the width of the instrumental resolution of a spectrometer operating in the resonance detector configuration and to achieve an effective subtraction of the neutron and gamma backgrounds. Preliminary experimental results, obtained from deep inelastic neutron scattering measurements on lead, zirconium hydride, and deuterium chloride samples, are presented

  15. Foil cycling technique for the VESUVIO spectrometer operating in the resonance detector configuration

    Science.gov (United States)

    Schooneveld, E. M.; Mayers, J.; Rhodes, N. J.; Pietropaolo, A.; Andreani, C.; Senesi, R.; Gorini, G.; Perelli-Cippo, E.; Tardocchi, M.

    2006-09-01

    This article reports a novel experimental technique, namely, the foil cycling technique, developed on the VESUVIO spectrometer (ISIS spallation source) operating in the resonance detector configuration. It is shown that with a proper use of two foils of the same neutron absorbing material it is possible, in a double energy analysis process, to narrow the width of the instrumental resolution of a spectrometer operating in the resonance detector configuration and to achieve an effective subtraction of the neutron and gamma backgrounds. Preliminary experimental results, obtained from deep inelastic neutron scattering measurements on lead, zirconium hydride, and deuterium chloride samples, are presented.

  16. Evaluations of the commercial spectrometer systems for safeguards applications using the germanium detectors

    International Nuclear Information System (INIS)

    Vo, D.T.

    1998-01-01

    Safeguards applications require the best spectrometer systems with excellent resolution, stability, and throughput. Instruments must perform well in all the situations and environments. Data communication to the computer should be convenient, fast, and reliable. The software should have all the necessary tools and be ease to use. Portable systems should be small in size, lightweight, and have a long battery life. Nine commercially available spectrometer systems are tested with both the planar and coaxial germanium detectors. Considering the performance of the Digital Signal Processors (DSP), digital-based spectroscopy may be the future of gamma-ray spectroscopy

  17. Pulser injection with subsequent removal for gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Hartwell, J.K.; Goodwin, S.G.; Johnson, L.O.; Killian, E.W.

    1990-01-01

    This patent describes a module for use with a gamma-ray spectroscopy system. The system includes a gamma-ray detector for detecting gamma-ray events and producing a signal representing the gamma-ray events, a converter responsive to the detector and capable of converting the signal to a spectrum, a storage memory responsive to the converter and capable of storing the spectrum at address locations in memory, and a pulser capable of injecting pulses into the signal produced by the detector. The module comprises: means for generating a logic pulse for controlling the pulser, the controlling means adapted for coupling to the pulser; means for generating separation of events logic to isolate the components of a combined gamma-ray---pulse spectrum, the separation of events logic means adapted for coupling to the converter and the storage memory with the capability of storing pulses at address locations in the storage memory separate from the gamma-ray events; means for receiving an imitating signal from the converter to generate a plurality of operations by the module; means for tracking variations in a gamma-ray---pulse spectrum brought on by external parameter changes; and means for interfacing with commercially developed gamma-ray spectrometry equipment

  18. Study of mixed programming gamma spectrum acquisition method based on MSP430F4618

    International Nuclear Information System (INIS)

    Li Yuezhong; Tang Bin; Zhang Zhongliang; Xie Xiaolin

    2012-01-01

    In order to reduce the hand-held gamma spectrometer measurements dead time and to complete the low-voltage and low-power design, the spectrum signal acquisition circuit is constituted by the ultra-low power microcontroller MSP430F4618 and its external signal conditioning circuit, anti-coincidence circuit interface and its on-chip sample hold and A/D converter. C language programming and assembly one have been used together. The sample hold and A/D conversion and spectrum acquisition programming is accomplished by assembly language, and the system monitoring and task scheduler designing is accomplished by C language programming. The handhold gamma spectrometer power supply, which just uses two No.5 rechargeable batteries, is designed by high-efficiency DC-DC circuit. The prototype gamma spectrometer is developed by the method, and its testing shows that the implementation of spectrum acquisition time is shorten by twice to 3 times, that is, the dead measurement can be reduced; and the machine operating current does not exceed 150 mA. By using two 2400 mAh No.5 rechargeable battery, the machine can work continuously more than 10 hours, and it can meet the application requirements. (authors)

  19. Broadband crystal spectrometer for the non-active and active phases of JET

    International Nuclear Information System (INIS)

    Engelhardt, W.; Fink, J.; Fussmann, G.; Krause, H.; Schilling, H.B.; Schumacher, U.

    1982-03-01

    The design study treats the possibilities of quantitatively measuring the Soft X-ray spectrum of JET with a double crystal spectrometer device in parallel mode. This spectrometer type is much suited for broad band soft X-ray spectroscopy, also - due to its folded optical pathway - during D-T operation of JET; the expected detector count rates are far above the background level. Methods to fulfill the important condition of parallel orientation of the two crystals, to shield the device against neutrons and gamma rays, to obtain spectral resolution sufficient for spectral line profile measurements and to upgrade the device for continuous spatial scanning of the JET plasma are presented. (orig.)

  20. Educational Testing of an Auditory Display of Mars Gamma Ray Spectrometer Data

    Science.gov (United States)

    Keller, J. M.; Pompea, S. M.; Prather, E. E.; Slater, T. F.; Boynton, W. V.; Enos, H. L.; Quinn, M.

    2003-12-01

    A unique, alternative educational and public outreach product was created to investigate the use and effectiveness of auditory displays in science education. The product, which allows students to both visualize and hear seasonal variations in data detected by the Gamma Ray Spectrometer (GRS) aboard the Mars Odyssey spacecraft, consists of an animation of false-color maps of hydrogen concentrations on Mars along with a musical presentation, or sonification, of the same data. Learners can access this data using the visual false-color animation, the auditory false-pitch sonification, or both. Central to the development of this product is the question of its educational effectiveness and implementation. During the spring 2003 semester, three sections of an introductory astronomy course, each with ˜100 non-science undergraduates, were presented with one of three different exposures to GRS hydrogen data: one auditory, one visual, and one both auditory and visual. Student achievement data was collected through use of multiple-choice and open-ended surveys administered before, immediately following, and three and six weeks following the experiment. It was found that the three student groups performed equally well in their ability to perceive and interpret the data presented. Additionally, student groups exposed to the auditory display reported a higher interest and engagement level than the student group exposed to the visual data alone. Based upon this preliminary testing,we have made improvements to both the educational product and our evaluation protocol. This fall, we will conduct further testing with ˜100 additional students, half receiving auditory data and half receiving visual data, and we will conduct interviews with individual students as they interface with the auditory display. Through this process, we hope to further assess both learning and engagement gains associated with alternative and multi-modal representations of scientific data that extend beyond

  1. Neutron and gamma-ray spectra of 239PuBe and 241AmBe

    International Nuclear Information System (INIS)

    Vega-Carrillo, H.R.; Manzanares-Acuna, Eduardo; Becerra-Ferreiro, A.M.; Carrillo-Nunez, Aureliano

    2002-01-01

    Neutron and gamma-ray spectra of 239 PuBe and 241 AmBe were measured and their dosimetric features were calculated. Neutron spectra were measured using a multisphere neutron spectrometer with a 6 LiI(Eu) scintillator. The 239 PuBe neutron spectrum was measured in an open environment, while the 241 AmBe neutron spectrum was measured in a closed environment. Gamma-ray spectra were measured using a NaI(Tl) scintillator using the same experimental conditions for both sources. The effect of measuring conditions for the 241 AmBe neutron spectrum indicates the presence of epithermal and thermal neutrons. The low-resolution neutron spectra obtained with the multisphere spectrometer allows one to calculate the dosimetric features of neutron sources. At 100 cm both sources produce approximately the same count rate as that of the 4.4 MeV gamma-ray per unit of alpha emitter activity

  2. LANL/Green Star spectrometer tests

    International Nuclear Information System (INIS)

    Sampson, T.E.; Cremers, T.L.; Vo, D.T.; Seldiakov, Y.P.; Dorin, A.B.; Kondrashov, M.V.; Timoshin, V.I.

    1997-12-01

    The US and Russia have agreed to the joint development of a nondestructive assay system for use to support the dismantlement of nuclear weapons in Russia. This nondestructive assay system will be used to measure plutonium produced by the conversion of Russian nuclear weapons. The NDA system for Russia will be patterned after the ARIES NDA system being constructed at Los Alamos. One goal of the program is to produce an NDA system for use in Russia that maximizes the use of Russian resources to facilitate maintenance and future upgrades. The Green Star SBS50 Single Board Spectrometer system (Green Star Ltd., Moscow, Russia) has been suggested for use as the data acquisition component for gamma ray instruments in the system. Possible uses are for plutonium isotopic analysis and also segmented gamma scanning. Green Star has also developed analysis software for the SBS50. This software, both plutonium isotopic analysis and uranium enrichment analysis, was developed specifically for customs/border inspection applications (low counting rate applications and identification as opposed to quantification) and was not intended for MC and A applications. Because of the relative immaturity of the Green Star plutonium isotopic analysis software (it has been under development for only one year and is patterned after US development circa 1980), it was tentatively agreed, before the tests, that the Russian NDA system would use the Los Alamos PC/FRAM software for plutonium isotopic analysis. However, it was also decided to include the Green Star plutonium isotopic software in the testing, both to quantify its performance for MC and A applications and also to provide additional data to Green Star for further development of their software. The main purpose of the testing was to evaluate the SBS-50 spectrometer as a data acquisition device for use with LANL software

  3. Measurements of keV-neutron capture {gamma} rays of fission products. 3

    Energy Technology Data Exchange (ETDEWEB)

    Igashira, Masayuki [Tokyo Inst. of Tech. (Japan). Research Lab. for Nuclear Reactors

    1997-03-01

    {gamma} rays from the keV-neutron capture reactions by {sup 143,145}Nd and {sup 153}Eu have been measured in a neutron energy region of 10 to 80 keV, using a large anti-Compton NaI(Tl) {gamma}-ray spectrometer and the {sup 7}Li(p,n){sup 7}Be pulsed neutron source with a 3-MV Pelletron accelerator. The preliminary results for the capture cross sections and {gamma}-ray spectra of those nuclei are presented and discussed. (author)

  4. Alpha-beta-gamma spectrometer as an aid in directing decontamination of soils

    International Nuclear Information System (INIS)

    Berger, C.D.

    1981-01-01

    This technique permits rapid assessment of alpha-beta-gamma-emitter contamination in soils at sufficiently low concentrations to direct field operations. Of particular importance is its applicability during initial decommissioning and decontamination surveys when characterization of alpha and beta contamination in the presence of a high gamma background is necessary. This system has not yet been made portable for in-situ use, but it is expected that results willbe favorable when operated as a field instrument, resulting in simplified standard decontamination operation

  5. CAMAC system for computer control of microwave spectrometers

    International Nuclear Information System (INIS)

    Zizka, G.; Turko, B.; Kolbe, B.

    1979-01-01

    An interface between a microwave spectrometer and a computer is described. It consists of three CAMAC modules and uses a standard CAMAC crate and controller. The hardware, in conjunction with appropriate software routines was designed to synchronize measurements, to collect data, and to control the microwave frequency and other experimental parameters

  6. Personnel neutron dose assessment upgrade: Volume 2, Field neutron spectrometer for health physics applications

    International Nuclear Information System (INIS)

    Brackenbush, L.W.; Reece, W.D.; Miller, S.D.

    1988-07-01

    Both the (ICRP) and the (NCPR) have recommended an increase in neutron quality factors and the adoption of effective dose equivalent methods. The series of reports entitled Personnel Neutron Dose Assessment Upgrade (PNL-6620) addresses these changes. Volume 1 in this series of reports (Personnel Neutron Dosimetry Assessment) provided guidance on the characteristics, use, and calibration of personnel neutron dosimeters in order to meet the new recommendations. This report, Volume 2: Field Neutron Spectrometer for Health Physics Applications describes the development of a portable field spectrometer which can be set up for use in a few minutes by a single person. The field spectrometer described herein represents a significant advance in improving the accuracy of neutron dose assessment. It permits an immediate analysis of the energy spectral distribution associated with the radiation from which neutron quality factor can be determined. It is now possible to depart from the use of maximum Q by determining and realistically applying a lower Q based on spectral data. The field spectrometer is made up of two modules: a detector module with built-in electronics and an analysis module with a IBM PC/reg sign/-compatible computer to control the data acquisition and analysis of data in the field. The unit is simple enough to allow the operator to perform spectral measurements with minimal training. The instrument is intended for use in steady-state radiation fields with neutrons energies covering the fission spectrum range. The prototype field spectrometer has been field tested in plutonium processing facilities, and has been proven to operate satisfactorily. The prototype field spectrometer uses a 3 He proportional counter to measure the neutron energy spectrum between 50 keV and 5 MeV and a tissue equivalent proportional counter (TEPC) to measure absorbed neutron dose

  7. A directional gamma-ray detector based on scintillator plates

    Energy Technology Data Exchange (ETDEWEB)

    Hanna, D., E-mail: hanna@physics.mcgill.ca; Sagnières, L.; Boyle, P.J.; MacLeod, A.M.L.

    2015-10-11

    A simple device for determining the azimuthal location of a source of gamma radiation, using ideas from astrophysical gamma-ray burst detection, is described. A compact and robust detector built from eight identical modules, each comprising a plate of CsI(Tl) scintillator coupled to a photomultiplier tube, can locate a point source of gamma rays with degree-scale precision by comparing the count rates in the different modules. Sensitivity to uniform environmental background is minimal.

  8. Using a Borated Panel to Form a Dual Neutron-Gamma Detector

    Energy Technology Data Exchange (ETDEWEB)

    Scott Wilde; Raymond Keegan

    2008-06-20

    A borated polyethylene plane placed between a neutron source and a gamma spectrometer is used to form a dual neutron-gamma detection system. The polyethylene thermalizes the source neutrons so that they are captured by {sup 10}B to produce a flux of 478 keV gamma-rays that radiate from the plane. This results in a buildup of count rate in the detector over that from a disk of the same diameter as the detector crystal (same thickness as the panel). Radiation portal systems are a potential application of this technique.

  9. ATLAS Muon Spectrometer Upgrades for the High Luminosity LHC

    CERN Document Server

    Valderanis, Chrysostomos; The ATLAS collaboration

    2015-01-01

    ATLAS Muon Spectrometer Upgrades for the High Luminosity LHC The luminosity of the LHC will increase up to 2x10^34 cm-2s-1 after the long shutdown in 2019 (phase-1 upgrade) and up to 7x10^34 cm-2s-1 after the long shutdown in 2025 (phase-2 upgrade). In order to cope with the increased particle fluxes, upgrades are envisioned for the ATLAS muon spectrometer. At phase-1, the current innermost stations of the ATLAS muon endcap tracking system (the Small Wheels) will be upgraded with 2x4-layer modules of Micromega detectors, sandwiched by two 4 layer modules of small strip Thin Gap Chambers on either side. Each 4-layer module of the so-called New Small Wheels covers a surface area of approximately 2 to 3 m2 for a total active area of 1200 m2 each for the two technologies. On such large area detectors, the mechanical precision (30 \\mu m along the precision coordinate and 80 \\mu m along the beam) is a key point and must be controlled and monitored along the process of construction and integration. The design and re...

  10. Nuclear Forensics using Gamma-ray Spectroscopy

    Directory of Open Access Journals (Sweden)

    Norman E. B.

    2016-01-01

    Full Text Available Much of George Dracoulis’s research career was devoted to utilising gamma-ray spectroscopy in fundamental studies in nuclear physics. This same technology is useful in a wide range of applications in the area of nuclear forensics. Over the last several years, our research group has made use of both high- and low-resolution gamma-ray spectrometers to: identify the first sample of plutonium large enough to be weighed; determine the yield of the Trinity nuclear explosion; measure fission fragment yields as a function of target nucleus and neutron energy; and observe fallout in the U. S. from the Fukushima nuclear reactor accident.

  11. Gamma ray spectroscopy monitoring method and apparatus

    Science.gov (United States)

    Stagg, William R; Policke, Timothy A

    2017-05-16

    The present invention relates generally to the field of gamma ray spectroscopy monitoring and a system for accomplishing same to monitor one or more aspects of various isotope production processes. In one embodiment, the present invention relates to a monitoring system, and method of utilizing same, for monitoring one or more aspects of an isotope production process where the monitoring system comprises: (A) at least one sample cell; (B) at least one measuring port; (C) at least one adjustable collimator device; (D) at least one shutter; and (E) at least one high resolution gamma ray spectrometer.

  12. Gamma-ray spectral determinations with a portable analyzer

    International Nuclear Information System (INIS)

    Eldridge, J.S.; Oakes, T.W.

    1978-01-01

    A portable sodium iodide spectrometer was used in a variety of field applications. The spectrometer is a battery-operated system complete with a 5 x 5 cm NaI(Tl) detector, 1024 channel memory divisible into four quadrants, special summation and calibration circuits, and a telemeter output for data transmittals. The portable spectrometer has been used to make in situ measurements around a radioactive waste burial ground. Typical spectra of 137 Cs and 60 Co were easily discernible at one such site. Uptake in vegetation near a sealed trench could be observed by placing the NaI(Tl) probe in the foliage. The extent of the spread of low-level contamination of 60 Co was determined in an area that had previously been decontaminated. The unique response of the two 60 Co gamma-rays could be obtained by subtracting the local background response within the computing spectrometer. The ability to perform qualitative identification and to assess hazards in emergency situations has been demonstrated

  13. Beta and gamma decay heat measurements between 0.1s--50,000s for neutron fission of 235U, 238U and 239Pu

    International Nuclear Information System (INIS)

    Schier, W.A.; Couchell, G.P.

    1993-01-01

    A helium-jet/tape-transport system is employed in the study of beta-particle and gamma-ray energy spectra of aggregate fission products as a function of time after fission. During the initial nine months of this project we have investigated the following areas: Design, assembly and characterization of a beta-particle spectrometer; Measurement of 235 U(n th ff) beta spectra for delay times 0.2 s to 12,000 s; Assembly and characterization of a 5 x 5 Nal(Tl) gamma-ray spectrometer; Measurement of 235 U(n th ff) gamma-ray spectra for delay times 0.2s to 1 5,500s; Assembly and characterization of HPGe gamma-ray spectrometer with a Nal(Tl) Compton-and-background-suppression annulus; Measurement of 235 U(n th ,ff) high-resolution gamma-ray spectra for delay times 0.6 s to over 100,000 s; Comparison of individual gamma-line intensities with ENDF/B-VI; Adaptation to our computer of unfolding program FERDO for beta and gamma aggregate fission-product energy spectra and development of a spectrum-stripping program for analysis of HPGe gamma-ray spectra; Study of the helium-jet fission-fragment elemental transfer efficiency. This work has resulted in the publication of twelve BAPS abstracts of presentations at scientific meetings. There are currently four Ph.D. and two M.S. candidates working on dissertations associated with the project

  14. Cosmic veto gamma-spectrometry for Comprehensive Nuclear-Test-Ban Treaty samples

    International Nuclear Information System (INIS)

    Burnett, J.L.; Davies, A.V.

    2014-01-01

    The Comprehensive Nuclear-Test-Ban Treaty (CTBT) is supported by a global network of monitoring stations that perform high-resolution gamma-spectrometry on air filter samples for the identification of 85 radionuclides. At the UK CTBT Radionuclide Laboratory (GBL15), a novel cosmic veto gamma-spectrometer has been developed to improve the sensitivity of station measurements, providing a mean background reduction of 80.8% with mean MDA improvements of 45.6%. The CTBT laboratory requirement for a 140 Ba MDA is achievable after 1.5 days counting compared to 5–7 days using conventional systems. The system consists of plastic scintillation plates that detect coincident cosmic-ray interactions within an HPGe gamma-spectrometer using the Canberra Lynx TM multi-channel analyser. The detector is remotely configurable using a TCP/IP interface and requires no dedicated coincidence electronics. It would be especially useful in preventing false-positives at remote station locations (e.g. Halley, Antarctica) where sample transfer to certified laboratories is logistically difficult. The improved sensitivity has been demonstrated for a CTBT air filter sample collected after the Fukushima incident

  15. Cosmic veto gamma-spectrometry for Comprehensive Nuclear-Test-Ban Treaty samples

    Science.gov (United States)

    Burnett, J. L.; Davies, A. V.

    2014-05-01

    The Comprehensive Nuclear-Test-Ban Treaty (CTBT) is supported by a global network of monitoring stations that perform high-resolution gamma-spectrometry on air filter samples for the identification of 85 radionuclides. At the UK CTBT Radionuclide Laboratory (GBL15), a novel cosmic veto gamma-spectrometer has been developed to improve the sensitivity of station measurements, providing a mean background reduction of 80.8% with mean MDA improvements of 45.6%. The CTBT laboratory requirement for a 140Ba MDA is achievable after 1.5 days counting compared to 5-7 days using conventional systems. The system consists of plastic scintillation plates that detect coincident cosmic-ray interactions within an HPGe gamma-spectrometer using the Canberra LynxTM multi-channel analyser. The detector is remotely configurable using a TCP/IP interface and requires no dedicated coincidence electronics. It would be especially useful in preventing false-positives at remote station locations (e.g. Halley, Antarctica) where sample transfer to certified laboratories is logistically difficult. The improved sensitivity has been demonstrated for a CTBT air filter sample collected after the Fukushima incident.

  16. Cosmic veto gamma-spectrometry for Comprehensive Nuclear-Test-Ban Treaty samples

    Energy Technology Data Exchange (ETDEWEB)

    Burnett, J.L., E-mail: jonathan.burnett@awe.co.uk; Davies, A.V.

    2014-05-21

    The Comprehensive Nuclear-Test-Ban Treaty (CTBT) is supported by a global network of monitoring stations that perform high-resolution gamma-spectrometry on air filter samples for the identification of 85 radionuclides. At the UK CTBT Radionuclide Laboratory (GBL15), a novel cosmic veto gamma-spectrometer has been developed to improve the sensitivity of station measurements, providing a mean background reduction of 80.8% with mean MDA improvements of 45.6%. The CTBT laboratory requirement for a {sup 140}Ba MDA is achievable after 1.5 days counting compared to 5–7 days using conventional systems. The system consists of plastic scintillation plates that detect coincident cosmic-ray interactions within an HPGe gamma-spectrometer using the Canberra Lynx{sup TM} multi-channel analyser. The detector is remotely configurable using a TCP/IP interface and requires no dedicated coincidence electronics. It would be especially useful in preventing false-positives at remote station locations (e.g. Halley, Antarctica) where sample transfer to certified laboratories is logistically difficult. The improved sensitivity has been demonstrated for a CTBT air filter sample collected after the Fukushima incident.

  17. Field Deployable Gamma Radiation Detectors for DHS Use

    Energy Technology Data Exchange (ETDEWEB)

    Sanjoy Mukhopadhyay

    2007-08-01

    Recently, the Department of Homeland Security (DHS) has integrated all nuclear detection research, development, testing, evaluation, acquisition, and operational support into a single office: the Domestic Nuclear Detection Office (DNDO). The DNDO has specific requirements set for all commercial off-the-shelf and government off-the-shelf radiation detection equipment and data acquisition systems. This article would investigate several recent developments in field deployable gamma radiation detectors that are attempting to meet the DNDO specifications. Commercially available, transportable, handheld radio isotope identification devices (RIID) are inadequate for DHS requirements in terms of sensitivity, resolution, response time, and reach-back capability. The leading commercial vendor manufacturing handheld gamma spectrometer in the United States is Thermo Electron Corporation. Thermo Electron's identiFINDER{trademark}, which primarily uses sodium iodide crystals (3.18 x 2.54cm cylinders) as gamma detectors, has a Full-Width-at-Half-Maximum energy resolution of 7 percent at 662 keV. Thermo Electron has just recently come up with a reach-back capability patented as RadReachBack{trademark} that enables emergency personnel to obtain real-time technical analysis of radiation samples they find in the field. The current project has the goal to build a prototype handheld gamma spectrometer, equipped with a digital camera and an embedded cell phone to be used as an RIID with higher sensitivity, better resolution, and faster response time (able to detect the presence of gamma-emitting radio isotopes within 5 seconds of approach), which will make it useful as a field deployable tool. The handheld equipment continuously monitors the ambient gamma radiation, and, if it comes across any radiation anomalies with higher than normal gamma gross counts, it sets an alarm condition. When a substantial alarm level is reached, the system automatically triggers the saving of relevant

  18. Field Deployable Gamma Radiation Detectors for DHS Use

    International Nuclear Information System (INIS)

    Sanjoy Mukhopadhyay

    2007-01-01

    Recently, the Department of Homeland Security (DHS) has integrated all nuclear detection research, development, testing, evaluation, acquisition, and operational support into a single office: the Domestic Nuclear Detection Office (DNDO). The DNDO has specific requirements set for all commercial off-the-shelf and government off-the-shelf radiation detection equipment and data acquisition systems. This article would investigate several recent developments in field deployable gamma radiation detectors that are attempting to meet the DNDO specifications. Commercially available, transportable, handheld radio isotope identification devices (RIID) are inadequate for DHS requirements in terms of sensitivity, resolution, response time, and reach-back capability. The leading commercial vendor manufacturing handheld gamma spectrometer in the United States is Thermo Electron Corporation. Thermo Electron's identiFINDER(trademark), which primarily uses sodium iodide crystals (3.18 x 2.54cm cylinders) as gamma detectors, has a Full-Width-at-Half-Maximum energy resolution of 7 percent at 662 keV. Thermo Electron has just recently come up with a reach-back capability patented as RadReachBack(trademark) that enables emergency personnel to obtain real-time technical analysis of radiation samples they find in the field. The current project has the goal to build a prototype handheld gamma spectrometer, equipped with a digital camera and an embedded cell phone to be used as an RIID with higher sensitivity, better resolution, and faster response time (able to detect the presence of gamma-emitting radio isotopes within 5 seconds of approach), which will make it useful as a field deployable tool. The handheld equipment continuously monitors the ambient gamma radiation, and, if it comes across any radiation anomalies with higher than normal gamma gross counts, it sets an alarm condition. When a substantial alarm level is reached, the system automatically triggers the saving of relevant

  19. Measuring 137Cs, 40K and decay products of 226Ra and 232Th in samples of different nature by a multidetector spectrometer

    International Nuclear Information System (INIS)

    Antovic, N.M.; Popovic, V.; Vukotic, P.

    2011-01-01

    A coincidence method for measuring 137 Cs, 40 K, 226 Ra and 232 Th decay products activity in soil, vegetation and fish samples, was applied to the six-crystal gamma-coincidence spectrometer PRIPYAT-2M. In this way, some problems appeared in simultaneous measurement of 137 Cs, 226 Ra and 232 Th by NaI(Tl) detectors and the PRIPYAT-2M spectrometer were solved. The obtained results were agreeable with the HPGe spectrometer ones. (author)

  20. Fermi LAT Observations of LS I +61 303: First Detection of an Orbital Modulation in GeV Gamma Rays

    Energy Technology Data Exchange (ETDEWEB)

    Abdo, A.A.; /Federal City Coll. /Naval Research Lab, Wash., D.C.; Ackermann, M.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Ajello, M.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Atwood, W.B.; /UC, Santa Cruz; Axelsson, M.; /Stockholm U., OKC /Stockholm U.; Baldini, L.; /INFN, Pisa; Ballet, J.; /DAPNIA, Saclay; Barbiellini, G.; /INFN, Trieste /Trieste U.; Bastieri, D.; /INFN, Padua /Padua U.; Baughman, B.M.; /Ohio State U.; Bechtol, K.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Bellazzini, R.; /INFN, Pisa; Berenji, B.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Blandford, R.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Bloom, E.D.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Bonamente, E.; /INFN, Perugia /Perugia U.; Borgland, A.W.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Bregeon, J.; /INFN, Pisa; Brez, A.; /INFN, Pisa; Brigida, M.; /Bari U. /INFN, Bari; Bruel, P.; /Ecole Polytechnique /Washington U., Seattle /Bari U. /INFN, Bari /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /IASF, Milan /Milan Polytechnic /DAPNIA, Saclay /ASDC, Frascati /INFN, Perugia /Perugia U. /NASA, Goddard /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /DAPNIA, Saclay /Naval Research Lab, Wash., D.C. /George Mason U. /NASA, Goddard /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /INFN, Perugia /Perugia U. /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /Montpellier U. /Sonoma State U. /Stockholm U., OKC /Royal Inst. Tech., Stockholm /Stockholm U. /DAPNIA, Saclay /NASA, Goddard /CSST, Baltimore /ASDC, Frascati /Naval Research Lab, Wash., D.C. /INFN, Trieste /Pavia U. /Bari U. /INFN, Bari /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /UC, Santa Cruz /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /SLAC /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /Grenoble, CEN; /more authors..

    2012-04-02

    This Letter presents the first results from the observations of LS I +61{sup o}303 using Large Area Telescope data from the Fermi Gamma-Ray Space Telescope between 2008 August and 2009 March. Our results indicate variability that is consistent with the binary period, with the emission being modulated at 26.6 {+-} 0.5 days. This constitutes the first detection of orbital periodicity in high-energy gamma rays (20 MeV-100 GeV, HE). The light curve is characterized by a broad peak after periastron, as well as a smaller peak just before apastron. The spectrum is best represented by a power law with an exponential cutoff, yielding an overall flux above 100 MeV of 0.82 {+-} 0.03(stat) {+-} 0.07(syst) 10{sup -6} ph cm{sup -2} s{sup -1}, with a cutoff at 6.3 {+-} 1.1(stat) {+-} 0.4(syst) GeV and photon index {Gamma} = 2.21 {+-} 0.04(stat) {+-} 0.06(syst). There is no significant spectral change with orbital phase. The phase of maximum emission, close to periastron, hints at inverse Compton scattering as the main radiation mechanism. However, previous very high-energy gamma ray (>100 GeV, VHE) observations by MAGIC and VERITAS show peak emission close to apastron. This and the energy cutoff seen with Fermi suggest that the link between HE and VHE gamma rays is nontrivial.

  1. Methods for fitting of efficiency curves obtained by means of HPGe gamma rays spectrometers; Metodos de ajuste de curvas de eficiencia obtidas por meio de espectrometros de HPGe

    Energy Technology Data Exchange (ETDEWEB)

    Cardoso, Vanderlei

    2002-07-01

    The present work describes a few methodologies developed for fitting efficiency curves obtained by means of a HPGe gamma-ray spectrometer. The interpolated values were determined by simple polynomial fitting and polynomial fitting between the ratio of experimental peak efficiency and total efficiency, calculated by Monte Carlo technique, as a function of gamma-ray energy. Moreover, non-linear fitting has been performed using a segmented polynomial function and applying the Gauss-Marquardt method. For the peak area obtainment different methodologies were developed in order to estimate the background area under the peak. This information was obtained by numerical integration or by using analytical functions associated to the background. One non-calibrated radioactive source has been included in the curve efficiency in order to provide additional calibration points. As a by-product, it was possible to determine the activity of this non-calibrated source. For all fittings developed in the present work the covariance matrix methodology was used, which is an essential procedure in order to give a complete description of the partial uncertainties involved. (author)

  2. An X-ray perspective on a gamma-ray mission

    DEFF Research Database (Denmark)

    Lund, Niels

    2003-01-01

    The most recent astrophysics mission of ESA is INTEGRAL, a mission dedicated to gamma-ray astronomy (Winkler et al. 2003). INTEGRAL carries two gamma-ray instruments: the imager, IBIS, and the spectrometer, SPI, and in addition an optical monitor, OMC, and an X-ray monitor, JEM-X. INTEGRAL is an ...... is an observatory mission with 70% of the observation time available to the general astronomical community through a peer-reviewed selection process. This paper describes the INTEGRAL mission primarily as seen from the JEM-X perspective....

  3. Optical fiber sensor for low dose gamma irradiation monitoring

    Science.gov (United States)

    de Andrés, Ana I.; Esteban, Ã.`scar; Embid, Miguel

    2016-05-01

    An optical fiber gamma ray detector is presented in this work. It is based on a Terbium doped Gadolinium Oxysulfide (Gd2O2S:Tb) scintillating powder which cover a chemically etched polymer fiber tip. This etching improves the fluorescence gathering by the optical fiber. The final diameter has been selected to fulfill the trade-off between light gathering and mechanical strength. Powder has been encapsulated inside a microtube where the fiber tip is immersed. The sensor has been irradiated with different air Kerma doses up to 2 Gy/h with a 137Cs source, and the spectral distribution of the fluorescence intensity has been recorded in a commercial grade CCD spectrometer. The obtained signal-to-noise ratio is good enough even for low doses, which has allowed to reduce the integration time in the spectrometer. The presented results show the feasibility for using low cost equipment to detect/measure ionizing radiation as gamma rays are.

  4. Sequence of the gamma-subunit of Spirulina platensis : a new principle of thiol modulation of F0F1 ATP synthase?

    NARCIS (Netherlands)

    Steinemann, D.; Lill, H

    1995-01-01

    The gene encoding the gamma subunit of Spirulina platensis F0F1, the relative of the chloroplast F1 subunit responsible for thiol activation, has been cloned and sequenced. As in other cyanobacteria, a specific couple of cysteines like those involved in thiol modulation of the chloroplast enzyme was

  5. Determination of gamma ray shielding parameters of rocks and concrete

    Science.gov (United States)

    Obaid, Shamsan S.; Gaikwad, Dhammajyot K.; Pawar, Pravina P.

    2018-03-01

    Gamma shielding parameters such as mass attenuation coefficient (μ/ρ), effective atomic number (Zeff) and electron density (Neff) have been measured and calculated for rocks and concrete in the energy range 122-1330 keV. The measurements have been carried out at 122, 356, 511, 662, 1170, 1275, 1330 keV gamma ray energies using a gamma spectrometer includes a NaI(Tl) scintillation detector and MCA card. The atomic and electronic cross sections have also been investigated. Experimental and calculated (WinXCom) values were compared, and good agreement has been observed within the experimental error. The obtained results showed that feldspathic basalt, compact basalt, volcanic rock, dolerite and pink granite are more efficient than the sandstone and concrete for gamma ray shielding applications.

  6. Levels in /sup 179/W studied in the /sup 181/Ta(p, 3n) reaction by on-line electron and gamma ray spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Meijer, B J; Konijn, J [Instituut voor Kernphysisch Onderzoek, Amsterdam (Netherlands); Klank, B; Jett, J H; Ristinen, R A [Colorado Univ., Boulder (USA)

    1975-01-01

    Levels in /sup 179/W have been deduced from in-beam gamma and conversion electron studies of the /sup 181/Ta(p, 3n)/sup 179/W reaction. The gamma-ray spectrum was studied with Ge(Li) detectors and a crystal diffraction spectrometer; the conversion electrons were measured with solenoid Si(Li) spectrometer. The multipolarities of some 50 transitions could be determined. Coriolis mixing of the Nilsson orbits with N = 6 was calculated.

  7. Gamma spectroscopy: from steady beams to radioactive beams

    International Nuclear Information System (INIS)

    Stezowski, O.

    2008-06-01

    The author gives an overview of his research works in the field of gamma spectroscopy. First, he recalls some results of experiments performed for the study of peculiar structures associated with different modes of nucleus rotation, and notably in the case of collective rotation of deformed and even super-deformed nuclei. Then, he details tools and methods used to experimentally determine the level scheme. The main characteristics of steady and radioactive beams are briefly presented, and their complementarities and differences are highlighted. Specific spectrometers and sensors are described. In a last chapter, the author discusses several research projects he is involved in, and more particularly the 'gamma tracking' which is the fundamental principle for gamma multi-sensors of the next generations

  8. Micromegas Detectors for the Muon Spectrometer Upgrade of the ATLAS Experiment

    CERN Document Server

    Iodice, Mauro; The ATLAS collaboration

    2015-01-01

    The Micromegas (MICRO MEsh GAseous Structure) have been proven along the years to be reliable detectors with excellent space resolution and high rate capability. Large area Micromegas will be employed for the first time in high-energy physics for the Muon Spectrometer upgrade of the ATLAS experiment at CERN LHC. A total surface of about 150 m$^2$ of the forward regions of the Muon Spectrometer will be equipped with 8 layers of Micromegas modules. Each module covers a surface from 2 to 3 m$^2$ for a total active area of 1200 m$^2$. Together with the small-strips Thin Gap Chambers, they will compose the two New Small Wheels, which will replace the innermost stations of the ATLAS Endcap Muon tracking system in the 2018/19 shutdown. The breakthroughs and developments of this type of Micro Pattern Gas Detector will be reviewed, along with the path towards the construction of the modules, which will take place in several production sites starting in 2015. An overview of the detector performances obtained in the rec...

  9. Micromegas Detectors for the Muon Spectrometer Upgrade of the ATLAS Experiment

    CERN Document Server

    Iodice, M; The ATLAS collaboration

    2014-01-01

    The Micromegas (MICRO MEsh GAseous Structure) chambers have been proven along the years to be reliable detectors with excellent space resolution and high rate capability. Large area Micromegas will be employed for the first time in high-energy physics for the Muon Spectrometer upgrade of the ATLAS experiment at CERN LHC. A total surface of about 150 m2 of the forward regions of the Muon Spectrometer will be equipped with 8 layers of Micromegas modules. Each module covers a surface from 2 to 3 m2 for a total active area of 1200 m2. Together with the small-strips Thin Gap Chambers, they will compose the two New Small Wheels, which will replace the innermost stations of the ATLAS Endcap Muon tracking system in the 2018/19 shutdown. The principles of operation and recent developments of this type of Micro Pattern Gas Detector will be reviewed, along with our plans towards the construction of the modules, which will take place in several production sites. An overview of the detector performances obtained in the re...

  10. FAST TIMING ANALYSIS OF CYGNUS X-1 USING THE SPECTROMETER ON THE INTERNATIONAL GAMMA-RAY ASTROPHYSICS LABORATORY

    International Nuclear Information System (INIS)

    Cabanac, Clement; Roques, Jean-Pierre; Jourdain, Elisabeth

    2011-01-01

    We report for the first time the high-frequency analysis of Cyg X-1 up to hard X-ray using the spectrometer on International Gamma-Ray Astrophysics Laboratory (INTEGRAL). After analyzing the possible contribution from the background, and using the INTEGRAL archive from 2005 March to 2008 May, power density spectra were obtained up to 130 keV. First, we show that their overall shape is very similar to that observed at lower energies as they are well described by sets of Lorentzians. The strength of this fast variability (up to 40 Hz) does not drop at high energy since we show that it remains at ∼25% rms, even in the highest energy bands. Second, the hard X-ray variability patterns of Cyg X-1 are state dependent: the softer the spectrum (or the lower the hardness ratio), the lower the total fractional variability and the higher the typical frequencies observed. The strength of the total variability as a function of energy and state is then investigated. By comparison with simultaneous and published RXTE/Proportional Counter Array data, we show that in the hard state it remains quite constant in the 2-130 keV energy range. In the softer state it is also flat up to 50 keV and may increase at higher energy. The implications of this behavior on the models are then discussed.

  11. Use of planar HPGe detector as a part of X-ray fluorescent spectrometer for educational purposes

    International Nuclear Information System (INIS)

    Verenchikova, M.S.; Kalinin, V.N.; Mikhajlov, V.A.

    2011-01-01

    This work shows the possibility of use of the nondedicated gamma and X-ray detection head on the basis of planar HPGe detector with a big sensitive area equal to 2000 mm''2 as a part of X-ray fluorescent spectrometer during students' practicum.

  12. Cosmic ray and gamma astrophysics with the AMS-02 experiment

    International Nuclear Information System (INIS)

    Natale, Sonia

    2006-01-01

    The Alpha Magnetic Spectrometer (AMS) is a particle physics detector designed to operate on the International Space Station (ISS) for a minimum period of three years. The aim of AMS is the direct detection of charged particles in the rigidity range from 0.5 GV to few TV to perform high statistics studies of cosmic rays in space and a search for antimatter and dark matter. AMS will provide precise gamma measurements in the GeV range. In addition, the good angular resolution and identification capabilities of the detector will allow clean studies of galactic and extra-galactic sources, the diffuse gamma background and gamma ray bursts

  13. Gamma-ray response of NE-213 measured between 2 and 11.5 MeV

    International Nuclear Information System (INIS)

    Ingersoll, D.T.; Wehring, B.W.; Starr, R.D.

    1976-01-01

    Because of the capability to discriminate between neutrons and gamma rays, NE-213 scintillators are useful as both fast-neutron and gamma-ray spectrometers. However, measured NE-213 Compton-recoil spectra require unfolding to yield gamma-ray energy spectra which entails a detailed knowledge of the gamma-ray response of the NE-213 detector system. Absolute measurements of the gamma-ray response of an NE-213 scintillator in the energy range of 2 to 11.5 MeV were made. The measurements were made using the University of Illinois superconducting electron microtron equipped with a gamma-ray monochromator. The response measurements will be used to construct a gamma-ray response matrix for NE-213 to be used with the FORIST unfolding code

  14. Development of the computer code to monitor gamma radiation in the nuclear facility environment

    International Nuclear Information System (INIS)

    Akhmad, Y. R.; Pudjiyanto, M.S.

    1998-01-01

    Computer codes for gamma radiation monitoring in the vicinity of nuclear facility which have been developed could be introduced to the commercial potable gamma analyzer. The crucial stage of the first year activity was succeeded ; that is the codes have been tested to transfer data file (pulse high distribution) from Micro NOMAD gamma spectrometer (ORTEC product) and the convert them into dosimetry and physics quantities. Those computer codes are called as GABATAN (Gamma Analyzer of Batan) and NAGABAT (Natural Gamma Analyzer of Batan). GABATAN code can isable to used at various nuclear facilities for analyzing gamma field up to 9 MeV, while NAGABAT could be used for analyzing the contribution of natural gamma rays to the exposure rate in the certain location

  15. Spatial image modulation to improve performance of computed tomography imaging spectrometer

    Science.gov (United States)

    Bearman, Gregory H. (Inventor); Wilson, Daniel W. (Inventor); Johnson, William R. (Inventor)

    2010-01-01

    Computed tomography imaging spectrometers ("CTIS"s) having patterns for imposing spatial structure are provided. The pattern may be imposed either directly on the object scene being imaged or at the field stop aperture. The use of the pattern improves the accuracy of the captured spatial and spectral information.

  16. Processing of data issued from {gamma} spectrometer. Application to the study of decay schemes; Traitement des informations issues d'un spectrometre {gamma}. Application a l'etude de schemas de desintegration

    Energy Technology Data Exchange (ETDEWEB)

    Boulanger, J P; Legrand, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    The main purpose of the following report is the study of a generation method of {gamma} spectra corresponding to any energy, from a library of some basic spectra. Then we point out how to establish the decay scheme of a radio-nuclide, in using an accurate analysis of full-energy peaks which appear in its complex spectrum, followed by a generation of plain spectra corresponding to the energies of the different transitions, and ending with a least-squares fitting procedure of the complex spectrum. The accuracy of the process is examined comparing the calculated spectra to the ones issued from two kinds of spectrometers (Na I(Tl) and Ge(Li)). The method is then applied to the study of {sup 134}Cs and {sup 95}Zr - {sup 95}Nb. (authors) [French] Le present rapport a pour principal objet l'etude d'une methode de generation de spectres {gamma} correspondant a n'importe quelle energie, a partir d'une bibliotheque de quelques spectres de reference. On montre ensuite comment on peut etablir le schema de desintegration d'un radionucleide, a l'aide d'une analyse precise des pics d'absorption totale apparaissant dans son spectre complexe, suivie d'une generation des spectres simples correspondant aux energies des diverses transitions, et en terminant par une decomposition du spectre complexe par la methode des moindres carres. On examine la validite du procede en comparant les spectres calcules a ceux obtenus avec deux types de detecteurs (scintillateurs et semi-conducteurs). On applique alors la methode a l'etude du {sup 134}Cs et du {sup 95}Zr - {sup 95}Nb. (auteurs)

  17. Gravitational Waves and Gamma-Rays from a Binary Neutron Star Merger: GW170817 and GRB 170817A

    NARCIS (Netherlands)

    Abbott, B. P.; Abbott, R.; Abbott, T. D.; Acernese, F.; Ackley, K.; Adams, C.; Adams, T.; Addesso, P.; Adhikari, R. X.; Adya, V. B.; Affeldt, C.; Afrough, M.; Agarwal, B.; Agathos, M.; Agatsuma, K.; Aggarwal, N.; Aguiar, O. D.; Aiello, L.; Ain, A.; Ajith, P.; Allen, B.; Allen, G.; Allocca, A.; Aloy, M. A.; Altin, P. A.; Amato, A.; Ananyeva, A.; Anderson, S. B.; Anderson, W. G.; Angelova, S. V.; Antier, S.; Appert, S.; Arai, K.; Araya, M. C.; Areeda, J. S.; Arnaud, N.; Arun, K. G.; Ascenzi, S.; Ashton, G.; Ast, M.; Aston, S. M.; Astone, P.; Atallah, D. V.; Aufmuth, P.; Aulbert, C.; AultONeal, K.; Austin, C.; Avila-Alvarez, A.; Babak, S.; Bacon, P.; Bader, M. K. M.; Bae, S.; Baker, P. T.; Baldaccini, F.; Ballardin, G.; Ballmer, S. W.; Banagiri, S.; Barayoga, J. C.; Barclay, S. E.; Barish, B. C.; Barker, D.; Barkett, K.; Barone, F.; Barr, B.; Barsotti, L.; Barsuglia, M.; Barta, D.; Bartlett, J.; Bartos, I.; Bassiri, R.; Basti, A.; Batch, J. C.; Bawaj, M.; Bayley, J. C.; Bazzan, M.; Becsy, B.; Beer, C.; Bejger, M.; Belahcene, I.; Bell, A. S.; Berger, B. K.; Bergmann, G.; Bero, J. J.; Berry, C. P. L.; Bersanetti, D.; Bertolini, A.; Betzwieser, J.; Bhagwat, S.; Bhandare, R.; Bilenko, I. A.; Billingsley, G.; Billman, C. R.; Birch, J.; Birney, R.; Birnholtz, O.; Biscans, S.; Biscoveanu, S.; Bisht, A.; Bitossi, M.; Biwer, C.; Bizouard, M. A.; Blackburn, J. K.; Blackman, J.; Blair, C. D.; Blair, D. G.; Blair, R. M.; Bloemen, S.; Bock, O.; Bode, N.; Boer, M.; Bogaert, G.; Bohe, A.; Bondu, F.; Bonilla, E.; Bonnand, R.; Boom, B. A.; Bork, R.; Boschi, V.; Bose, S.; Bossie, K.; Bouffanais, Y.; Bozzi, A.; Bradaschia, C.; Brady, P. R.; Branchesi, M.; Brau, J. E.; Briant, T.; Brillet, A.; Brinkmann, M.; Brisson, V.; Brockill, P.; Broida, J. E.; Brooks, A. F.; Brown, D. A.; Brown, D. D.; Brunett, S.; Buchanan, C. C.; Buikema, A.; Bulik, T.; Bulten, H. J.; Buonanno, A.; Buskulic, D.; Buy, C.; Byer, R. L.; Cabero, M.; Cadonati, L.; Cagnoli, G.; Cahillane, C.; Bustillo, J. Calderon; Callister, T. A.; Calloni, E.; Camp, J. B.; Canepa, M.; Canizares, P.; Cannon, K. C.; Cao, H.; Cao, J.; Capano, C. D.; Capocasa, E.; Carbognani, F.; Caride, S.; Carney, M. F.; Diaz, J. Casanueva; Casentini, C.; Caudill, S.; Cavaglia, M.; Cavalier, F.; Cavalieri, R.; Cella, G.; Cepeda, C. B.; Cerda-Duran, P.; Cerretani, G.; Cesarini, E.; Chamberlin, S. J.; Chan, M.; Chao, S.; Charlton, P.; Chase, E.; Chassande-Mottin, E.; Chatterjee, D.; Chatziioannou, K.; Cheeseboro, B. D.; Chen, H. Y.; Chen, X.; Chen, Y.; Cheng, H. -P.; Chia, H.; Chincarini, A.; Chiummo, A.; Chmiel, T.; Cho, H. S.; Cho, M.; Chow, J. H.; Christensen, N.; Chu, Q.; Chua, A. J. K.; Chua, S.; Chung, A. K. W.; Chung, S.; Ciani, G.; Ciolfi, R.; Cirelli, C. E.; Cirone, A.; Clara, F.; Clark, J. A.; Clearwater, P.; Cleva, F.; Cocchieri, C.; Coccia, E.; Cohadon, P. -F.; Cohen, D.; Colla, A.; Collette, C. G.; Cominsky, L. R.; Constancio, M., Jr.; Conti, L.; Cooper, S. J.; Corban, P.; Corbitt, T. R.; Cordero-Carrion, I.; Corley, K. R.; Cornish, N.; Corsi, A.; Cortese, S.; Costa, C. A.; Coughlin, M. W.; Coughlin, S. B.; Coulon, J. -P.; Countryman, S. T.; Couvares, P.; Covas, P. B.; Cowan, E. E.; Coward, D. M.; Cowart, M. J.; Coyne, D. C.; Coyne, R.; Creighton, J. D. E.; Creighton, T. D.; Cripe, J.; Crowder, S. G.; Cullen, T. J.; Cumming, A.; Cunningham, L.; Cuoco, E.; Dal Canton, T.; Dalya, G.; Danilishin, S. L.; D'Antonio, S.; Danzmann, K.; Dasgupta, A.; Costa, C. F. Da Silva; Dattilo, V.; Dave, I.; Davier, M.; Davis, D.; Daw, E. J.; Day, B.; De, S.; Debra, D.; Degallaix, J.; De laurentis, M.; Deleglise, S.; Del Pozzo, W.; Demos, N.; Denker, T.; Dent, T.; De Pietri, R.; Dergachev, V.; De Rosa, R.; DeRosa, R. T.; De Rossi, C.; DeSalvo, R.; de Varona, O.; Devenson, J.; Dhurandhar, S.; Diaz, M. C.; Di Fiore, L.; Di Giovanni, M.; Di Girolamo, T.; Di Lieto, A.; Di Pace, S.; Di Palma, I.; Di Renzo, F.; Doctor, Z.; Dolique, V.; Donovan, F.; Dooley, K. L.; Doravari, S.; Dorrington, I.; Douglas, R.; Alvarez, M. Dovale; Downes, T. P.; Drago, M.; Dreissigacker, C.; Driggers, J. C.; Du, Z.; Ducrot, M.; Dupej, P.; Dwyer, S. E.; Edo, T. B.; Edwards, M. C.; Effler, A.; Eggenstein, H. -B.; Ehrens, P.; Eichholz, J.; Eikenberry, S. S.; Eisenstein, R. A.; Essick, R. C.; Estevez, D.; Etienne, Z. B.; Etzel, T.; Evans, M.; Evans, T. M.; Factourovich, M.; Fafone, V.; Fair, H.; Fairhurst, S.; Fan, X.; Farinon, S.; Farr, B.; Farr, W. M.; Fauchon-Jones, E. J.; Favata, M.; Fays, M.; Fee, C.; Fehrmann, H.; Feicht, J.; Fejer, M. M.; Fernandez-Galiana, A.; Ferrante, I.; Ferreira, E. C.; Ferrini, F.; Fidecaro, F.; Finstad, D.; Fiori, I.; Fiorucci, D.; Fishbach, M.; Fisher, R. P.; Fitz-Axen, M.; Flaminio, R.; Fletcher, M.; Fong, H.; Font, J. A.; Forsyth, P. W. F.; Forsyth, S. S.; Fournier, J. -D.; Frasca, S.; Frasconi, F.; Frei, Z.; Freise, A.; Frey, R.; Frey, V.; Fries, E. M.; Fritschel, P.; Frolov, V. V.; Fulda, P.; Fyffe, M.; Gabbard, H.; Gadre, B. U.; Gaebel, S. M.; Gair, J. R.; Gammaitoni, L.; Ganija, M. R.; Gaonkar, S. G.; Garcia-Quiros, C.; Garufi, F.; Gateley, B.; Gaudio, S.; Gaur, G.; Gayathri, V.; Gehrels, N.; Gemme, G.; Genin, E.; Gennai, A.; George, D.; George, J.; Gergely, L.; Germain, V.; Ghonge, S.; Ghosh, Abhirup; Ghosh, Archisman; Ghosh, S.; Giaime, J. A.; Giardina, K. D.; Giazotto, A.; Gill, K.; Glover, L.; Goetz, E.; Goetz, R.; Gomes, S.; Goncharov, B.; Gonzalez, G.; Castro, J. M. Gonzalez; Gopakumar, A.; Gorodetsky, M. L.; Gossan, S. E.; Gosselin, M.; Gouaty, R.; Grado, A.; Graef, C.; Granata, M.; Grant, A.; Gras, S.; Gray, C.; Greco, G.; Green, A. C.; Gretarsson, E. M.; Groot, P.; Grote, H.; Grunewald, S.; Gruning, P.; Guidi, G. M.; Guo, X.; Gupta, A.; Gupta, M. K.; Gushwa, K. E.; Gustafson, E. K.; Gustafson, R.; Halim, O.; Hall, B. R.; Hall, E. D.; Hamilton, E. Z.; Hammond, G.; Haney, M.; Hanke, M. M.; Hanks, J.; Hanna, C.; Hannam, M. D.; Hannuksela, O. A.; Hanson, J.; Hardwick, T.; Harms, J.; Harry, G. M.; Harry, I. W.; Hart, M. J.; Haster, C. -J.; Haughian, K.; Healy, J.; Heidmann, A.; Heintze, M. C.; Heitmann, H.; Hello, P.; Hemming, G.; Hendry, M.; Heng, I. S.; Hennig, J.; Heptonstall, A. W.; Heurs, M.; Hild, S.; Hinderer, T.; Hoak, D.; Hofman, D.; Holt, K.; Holz, D. E.; Hopkins, P.; Horst, C.; Hough, J.; Houston, E. A.; Howell, E. J.; Hreibi, A.; Hu, Y. M.; Huerta, E. A.; Huet, D.; Hughey, B.; Husa, S.; Huttner, S. H.; Huynh-Dinh, T.; Indik, N.; Inta, R.; Intini, G.; Isa, H. N.; Isac, J. -M.; Isi, M.; Iyer, B. R.; Izumi, K.; Jacqmin, T.; Jani, K.; Jaranowski, P.; Jawahar, S.; Jimenez-Forteza, F.; Johnson, W. W.; Johnson-McDaniel, N. K.; Jones, D. I.; Jones, R.; Jonker, R. J. G.; Ju, L.; Junker, J.; Kalaghatgi, C. V.; Kalogera, V.; Kamai, B.; Kandhasamy, S.; Kang, G.; Kanner, J. B.; Kapadia, S. J.; Karki, S.; Karvinen, K. S.; Kasprzack, M.; Kastaun, W.; Katolik, M.; Katsavounidis, E.; Katzman, W.; Kaufer, S.; Kawabe, K.; Kefelian, F.; Keitel, D.; Kemball, A. J.; Kennedy, R.; Kent, C.; Key, J. S.; Khalili, F. Y.; Khan, I.; Khan, S.; Khan, Z.; Khazanov, E. A.; Kijbunchoo, N.; Kim, Chunglee; Kim, J. C.; Kim, K.; Kim, W.; Kim, W. S.; Kim, Y. -M.; Kimbrell, S. J.; King, E. J.; King, P. J.; Kinley-Hanlon, M.; Kirchhoff, R.; Kissel, J. S.; Kleybolte, L.; Klimenko, S.; Knowles, T. D.; Koch, P.; Koehlenbeck, S. M.; Koley, S.; Kondrashov, V.; Kontos, A.; Korobko, M.; Korth, W. Z.; Kowalska, I.; Kozak, D. B.; Kraemer, C.; Kringel, V.; Krishnan, B.; Krolak, A.; Kuehn, G.; Kumar, P.; Kumar, R.; Kumar, S.; Kuo, L.; Kutynia, A.; Kwang, S.; Lackey, B. D.; Lai, K. H.; Landry, M.; Lang, R. N.; Lange, J.; Lantz, B.; Lanza, R. K.; Lartaux-Vollard, A.; Lasky, P. D.; Laxen, M.; Lazzarini, A.; Lazzaro, C.; Leaci, P.; Leavey, S.; Lee, C. H.; Lee, H. K.; Lee, H. M.; Lee, H. W.; Lee, K.; Lehmann, J.; Lenon, A.; Leonardi, M.; Leroy, N.; Letendre, N.; Levin, Y.; Li, T. G. F.; Linker, S. D.; Littenberg, T. B.; Liu, J.; Lo, R. K. L.; Lockerbie, N. A.; London, L. T.; Lord, J. E.; Lorenzini, M.; Loriette, V.; Lormand, M.; Losurdo, G.; Lough, J. D.; Lousto, C. O.; Lovelace, G.; Lueck, H.; Lumaca, D.; Lundgren, A. P.; Lynch, R.; Ma, Y.; Macas, R.; Macfoy, S.; Machenschalk, B.; MacInnis, M.; Macleod, D. M.; Hernandez, I. Magana; Magana-Sandoval, F.; Zertuche, L. Magana; Magee, R. M.; Majorana, E.; Maksimovic, I.; Man, N.; Mandic, V.; Mangano, V.; Mansell, G. L.; Manske, M.; Mantovani, M.; Marchesoni, F.; Marion, F.; Marka, S.; Marka, Z.; Markakis, C.; Markosyan, A. S.; Markowitz, A.; Maros, E.; Marquina, A.; Martelli, F.; Martellini, L.; Martin, I. W.; Martin, R. M.; Martynov, D. V.; Mason, K.; Massera, E.; Masserot, A.; Massinger, T. J.; Masso-Reid, M.; Mastrogiovanni, S.; Matas, A.; Matichard, F.; Matone, L.; Mavalvala, N.; Mazumder, N.; McCarthy, R.; McClelland, D. E.; McCormick, S.; McCuller, L.; McGuire, S. C.; McIntyre, G.; McIver, J.; McManus, D. J.; McNeill, L.; Mcrae, T.; McWilliams, S. T.; Meacher, D.; Meadors, G. D.; Mehmet, M.; Meidam, J.; Mejuto-Villa, E.; Melatos, A.; Mendell, G.; Mercer, R. A.; Merilh, E. L.; Merzougui, M.; Meshkov, S.; Messenger, C.; Messick, C.; Metzdorff, R.; Meyers, P. M.; Miao, H.; Michel, C.; Middleton, H.; Mikhailov, E. E.; Milano, L.; Miller, A. L.; Miller, B. B.; Miller, J.; Millhouse, M.; Milovich-Goff, M. C.; Minazzoli, O.; Minenkov, Y.; Ming, J.; Mishra, C.; Mitra, S.; Mitrofanov, V. P.; Mitselmakher, G.; Mittleman, R.; Moffa, D.; Moggi, A.; Mogushi, K.; Mohan, M.; Mohapatra, S. R. P.; Montani, M.; Moore, C. J.; Moraru, D.; Moreno, G.; Morriss, S. R.; Mours, B.; Mow-Lowry, C. M.; Mueller, G.; Muir, A. W.; Mukherjee, Arunava; Mukherjee, D.; Mukherjee, S.; Mukund, N.; Mullavey, A.; Munch, J.; Muniz, E. A.; Muratore, M.; Murray, P. G.; Napier, K.; Nardecchia, I.; Naticchioni, L.; Nayak, R. K.; Neilson, J.; Nelemans, G.; Nelson, T. J. N.; Nery, M.; Neunzert, A.; Nevin, L.; Newport, J. M.; Newton, G.; Ng, K. K. Y.; Nguyen, T. T.; Nichols, D.; Nielsen, A. B.; Nissanke, S.; Nitz, A.; Noack, A.; Nocera, F.; Nolting, D.; North, C.; Nuttall, L. K.; Oberling, J.; O'Dea, G. D.; Ogin, G. H.; Oh, J. J.; Oh, S. H.; Ohme, F.; Okada, M. A.; Oliver, M.; Oppermann, P.; Oram, Richard J.; O'Reilly, B.; Ormiston, R.; Ortega, L. F.; O'Shaughnessy, R.; Ossokine, S.; Ottaway, D. J.; Overmier, H.; Owen, B. J.; Pace, A. E.; Page, J.; Page, M. A.; Pai, A.; Pai, S. A.; Palamos, J. R.; Palashov, O.; Palomba, C.; Pal-Singh, A.; Pan, Howard; Pan, Huang-Wei; Pang, B.; Pang, P. T. H.; Pankow, C.; Pannarale, F.; Pant, B. C.; Paoletti, F.; Paoli, A.; Papa, M. A.; Parida, A.; Parker, W.; Pascucci, D.; Pasqualetti, A.; Passaquieti, R.; Passuello, D.; Patil, M.; Patricelli, B.; Pearlstone, B. L.; Pedraza, M.; Pedurand, R.; Pekowsky, L.; Pele, A.; Penn, S.; Perez, C. J.; Perreca, A.; Perri, L. M.; Pfeiffer, H. P.; Phelps, M.; Piccinni, O. J.; Pichot, M.; Piergiovanni, F.; Pierro, V.; Pillant, G.; Pinard, L.; Pinto, I. M.; Pirello, M.; Pitkin, M.; Poe, M.; Poggiani, R.; Popolizio, P.; Porter, E. K.; Post, A.; Powell, J.; Prasad, J.; Pratt, J. W. W.; Pratten, G.; Predoi, V.; Prestegard, T.; Prijatelj, M.; Principe, M.; Privitera, S.; Prodi, G. A.; Prokhorov, L. G.; Puncken, O.; Punturo, M.; Puppo, P.; Puerrer, M.; Qi, H.; Quetschke, V.; Quintero, E. A.; Quitzow-James, R.; Raab, F. J.; Rabeling, D. S.; Radkins, H.; Raffai, P.; Raja, S.; Rajan, C.; Rajbhandari, B.; Rakhmanov, M.; Ramirez, K. E.; Ramos-Buades, A.; Rapagnani, P.; Raymond, V.; Razzano, M.; Read, J.; Regimbau, T.; Rei, L.; Reid, S.; Reitze, D. H.; Ren, W.; Reyes, S. D.; Ricci, F.; Ricker, P. M.; Rieger, S.; Riles, K.; Rizzo, M.; Robertson, N. A.; Robie, R.; Robinet, F.; Rocchi, A.; Rolland, L.; Rollins, J. G.; Roma, V. J.; Romano, R.; Romel, C. L.; Romie, J. H.; Rosinska, D.; Ross, M. P.; Rowan, S.; Ruediger, A.; Ruggi, P.; Rutins, G.; Ryan, K.; Sachdev, S.; Sadecki, T.; Sadeghian, L.; Sakellariadou, M.; Salconi, L.; Saleem, M.; Salemi, F.; Samajdar, A.; Sammut, L.; Sampson, L. M.; Sanchez, E. J.; Sanchez, L. E.; Sanchis-Gual, N.; Sandberg, V.; Sanders, J. R.; Sassolas, B.; Sathyaprakash, B. S.; Saulson, P. R.; Sauter, O.; Savage, R. L.; Sawadsky, A.; Schale, P.; Scheel, M.; Scheuer, J.; Schmidt, J.; Schmidt, P.; Schnabel, R.; Schofield, R. M. S.; Schoenbeck, A.; Schreiber, E.; Schuette, D.; Schulte, B. W.; Schutz, B. F.; Schwalbe, S. G.; Scott, J.; Scott, S. M.; Seidel, E.; Sellers, D.; Sengupta, A. S.; Sentenac, D.; Sequino, V.; Sergeev, A.; Shaddock, D. A.; Shaffer, T. J.; Shah, A. A.; Shahriar, M. S.; Shaner, M. B.; Shao, L.; Shapiro, B.; Shawhan, P.; Sheperd, A.; Shoemaker, D. H.; Shoemaker, D. M.; Siellez, K.; Siemens, X.; Sieniawska, M.; Sigg, D.; Silva, A. D.; Singer, L. P.; Singh, A.; Singhal, A.; Sintes, A. M.; Slagmolen, B. J. J.; Smith, B.; Smith, R. J. E.; Smith, R. J. E.; Somala, S.; Son, E. J.; Sonnenberg, J. A.; Sorazu, B.; Sorrentino, F.; Souradeep, T.; Spencer, A. P.; Srivastava, A. K.; Staats, K.; Staley, A.; Steinke, M.; Steinlechner, J.; Steinlechner, S.; Steinmeyer, D.; Stevenson, S. P.; Stone, R.; Stops, D. J.; Strain, K. A.; Stratta, G.; Strigin, S. E.; Strunk, A.; Sturani, R.; Stuver, A. L.; Summerscales, T. Z.; Sun, L.; Sunil, S.; Suresh, J.; Sutton, P. J.; Swinkels, B. L.; Szczepanczyk, M. J.; Tacca, M.; Tait, S. C.; Talbot, C.; Talukder, D.; Tanner, D. B.; Tapai, M.; Taracchini, A.; Tasson, J. D.; Taylor, J. A.; Taylor, R.; Tewari, S. V.; Theeg, T.; Thies, F.; Thomas, E. G.; Thomas, M.; Thomas, P.; Thorne, K. A.; Thorne, K. S.; Thrane, E.; Tiwari, S.; Tiwari, V.; Tokmakov, K. V.; Toland, K.; Tonelli, M.; Tornasi, Z.; Torres-Forne, A.; Torrie, C. I.; Toyra, D.; Travasso, F.; Traylor, G.; Trinastic, J.; Tringali, M. C.; Trozzo, L.; Tsang, K. W.; Tse, M.; Tso, R.; Tsukada, L.; Tsuna, D.; Tuyenbayev, D.; Ueno, K.; Ugolini, D.; Unnikrishnan, C. S.; Urban, A. L.; Usman, S. A.; Vahlbruch, H.; Vajente, G.; Valdes, G.; van Bakel, N.; van Beuzekom, M.; Van den Brand, J. F. J.; Van den Broeck, C.; Vander-Hyde, D. C.; Van der Schaaf, L.; van Heijningen, J. V.; van Veggel, A. A.; Vardaro, M.; Varma, V.; Vass, S.; Vasuth, M.; Vecchio, A.; Vedovato, G.; Veitch, J.; Veitch, P. J.; Venkateswara, K.; Venugopalan, G.; Verkindt, D.; Vetrano, F.; Vicere, A.; Viets, A. D.; Vinciguerra, S.; Vine, D. J.; Vinet, J. -Y.; Vitale, S.; Vo, T.; Vocca, H.; Vorvick, C.; Vyatchanin, S. P.; Wade, A. R.; Wade, L. E.; Wade, M.; Walet, R.; Walker, M.; Wallace, L.; Walsh, S.; Wang, G.; Wang, H.; Wang, J. Z.; Wang, W. H.; Wang, Y. F.; Ward, R. L.; Warner, J.; Was, M.; Watchi, J.; Weaver, B.; Wei, L. -W.; Weinert, M.; Weinstein, A. J.; Weiss, R.; Wen, L.; Wessel, E. K.; Wessels, P.; Westerweck, J.; Westphal, T.; Wette, K.; Whelan, J. T.; Whitcomb, S. E.; Whiting, B. F.; Whittle, C.; Wilken, D.; Williams, D.; Williams, R. D.; Williamson, A. R.; Willis, J. L.; Willke, B.; Wimmer, M. H.; Winkler, W.; Wipf, C. C.; Wittel, H.; Woan, G.; Woehler, J.; Wofford, J.; Wong, K. W. K.; Worden, J.; Wright, J. L.; Wu, D. S.; Wysocki, D. M.; Xiao, S.; Yamamoto, H.; Yancey, C. C.; Yang, L.; Yap, M. J.; Yazback, M.; Yu, Hang; Yu, Haocun; Yvert, M.; Zadrozny, A.; Zanolin, M.; Zelenova, T.; Zendri, J. -P.; Zevin, M.; Zhang, L.; Zhang, M.; Zhang, T.; Zhang, Y. -H.; Zhao, C.; Zhou, M.; Zhou, Z.; Zhu, S. J.; Zhu, X. J.; Zimmerman, A. B.; Zucker, M. E.; Zweizig, J.; Burns, E.; Veres, P.; Kocevski, D.; Racusin, J.; Goldstein, A.; Connaughton, V.; Briggs, M. S.; Blackburn, L.; Hamburg, R.; Hui, C. M.; von Kienlin, A.; McEnery, J.; Preece, R. D.; Wilson-Hodge, C. A.; Bissaldi, E.; Cleveland, W. H.; Gibby, M. H.; Giles, M. M.; Kippen, R. M.; McBreen, S.; Meegan, C. A.; Paciesas, W. S.; Poolakkil, S.; Roberts, O. J.; Stanbro, M.; Savchenko, V.; Ferrigno, C.; Kuulkers, E.; Bazzano, A.; Bozzo, E.; Brandt, S.; Chenevez, J.; Courvoisier, T. J. -L.; Diehl, R.; Domingo, A.; Hanlon, L.; Jourdain, E.; Laurent, P.; Lebrun, F.; Lutovinov, A.; Mereghetti, S.; Natalucci, L.; Rodi, J.; Roques, J. -P.; Sunyaev, R.; Ubertini, P.

    2017-01-01

    On 2017 August 17, the gravitational-wave event GW170817 was observed by the Advanced LIGO and Virgo detectors, and the gamma-ray burst (GRB) GRB 170817A was observed independently by the Fermi Gamma-ray Burst Monitor, and the Anti-Coincidence Shield for the Spectrometer for the International

  18. Processing of data issued from a {gamma} spectrometer; Traitement des informations issues d'un spectrometre {gamma}

    Energy Technology Data Exchange (ETDEWEB)

    Boulanger, J P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1966-03-01

    The purpose of the following report is the study of computation method applied to analysis by gamma spectrometry. We first study quantitative analysis by the least-squares method, improved by a gain-shift correction. Then the single full-energy peaks and the resolution of complex peaks are dealt with. In both cases, the calculation principle, then the systematic tests achieved in order to-prove their validity and determine their application ranges are described and finally some experimental results appropriate to illustrate their possibilities are presented. (author) [French] Le present rapport a pour objet l'etude de methodes de calcul applicables a l'analyse par spectrometrie gamma. On etudie d'abord l'analyse quantitative par la methode des moindres carres, completee par une correction de derive du gain. Puis on examine les pics d'absorption totale simples et la resolution des pics complexes. Dans les deux cas, on expose le principe des calculs et les essais systematiques effectues pour eprouver leur validite et definir leurs domaines d'application, ainsi que quelques resultats experimentaux propres a illustrer leurs possibilites.

  19. Wide-Field Gamma-Spectrometer BDRG: GRB Monitor On-Board the Lomonosov Mission

    Science.gov (United States)

    Svertilov, S. I.; Panasyuk, M. I.; Bogomolov, V. V.; Amelushkin, A. M.; Barinova, V. O.; Galkin, V. I.; Iyudin, A. F.; Kuznetsova, E. A.; Prokhorov, A. V.; Petrov, V. L.; Rozhkov, G. V.; Yashin, I. V.; Gorbovskoy, E. S.; Lipunov, V. M.; Park, I. H.; Jeong, S.; Kim, M. B.

    2018-02-01

    The study of GRB prompt emissions (PE) is one of the main goals of the Lomonosov space mission. The payloads of the GRB monitor (BDRG) with the wide-field optical cameras (SHOK) and the ultra-fast flash observatory (UFFO) onboard the Lomonosov satellite are intended for the observation of GRBs, and in particular, their prompt emissions. The BDRG gamma-ray spectrometer is designed to obtain the temporal and spectral information of GRBs in the energy range of 10-3000 keV as well as to provide GRB triggers on several time scales (10 ms, 1 s and 20 s) for ground and space telescopes, including the UFFO and SHOK. The BDRG instrument consists of three identical detector boxes with axes shifted by 90° from each other. This configuration allows us to localize a GRB source in the sky with an accuracy of ˜ 2°. Each BDRG box contains a phoswich NaI(Tl)/CsI(Tl) scintillator detector. A thick CsI(Tl) crystal in size of \\varnothing 130 × 17 mm is placed underneath the NaI(Tl) as an active shield in the soft energy range and as the main detector in the hard energy range. The ratio of the CsI(Tl) to NaI(Tl) event rates at varying energies can be employed as an independent metric to distinguish legitimate GRB signals from false positives originating from electrons in near-Earth vicinities. The data from three detectors are collected in a BA BDRG information unit, which generates a GRB trigger and a set of data frames in output format. The scientific data output is ˜ 500 Mb per day, including ˜ 180 Mb of continuous data for events with durations in excess of 100 ms for 16 channels in each detector, detailed energy spectra, and sets of frames with ˜ 5 Mb of detailed information for each burst-like event. A number of pre-flight tests including those for the trigger algorithm and calibration were carried out to confirm the reliability of the BDRG for operation in space.

  20. Time differential {sup 57}Fe Mössbauer spectrometer with unique 4π YAP:Ce 122.06 keV gamma-photon detector

    Energy Technology Data Exchange (ETDEWEB)

    Novak, Petr [Department of Experimental Physics, Faculty of Science, Palacky University, 17. listopadu 1192/12, 77 146 Olomouc (Czech Republic); Pechousek, Jiri, E-mail: jiri.pechousek@upol.cz [Department of Experimental Physics, Faculty of Science, Palacky University, 17. listopadu 1192/12, 77 146 Olomouc (Czech Republic); Prochazka, Vit [Department of Experimental Physics, Faculty of Science, Palacky University, 17. listopadu 1192/12, 77 146 Olomouc (Czech Republic); Navarik, Jakub [Regional Centre of Advanced Technologies and Materials, Department of Experimental Physics, Faculty of Science, Palacky University, 17. listopadu 12, 77 146 Olomouc (Czech Republic); Kouril, Lukas; Kohout, Pavel; Vrba, Vlastimil [Department of Experimental Physics, Faculty of Science, Palacky University, 17. listopadu 1192/12, 77 146 Olomouc (Czech Republic); Machala, Libor [Regional Centre of Advanced Technologies and Materials, Department of Experimental Physics, Faculty of Science, Palacky University, 17. listopadu 12, 77 146 Olomouc (Czech Republic)

    2016-10-01

    This paper presents a conceptually new design of the {sup 57}Fe Time Differential Mössbauer Spectrometer (TDMS) with the gamma-photon detector optimized for registration of a radiation emitted in a maximum solid angle. A high detection efficiency of 80% in 4π region was achieved for 122.06 keV photons emitted from {sup 57}Co source. Detector parameters have been optimized for the use in the Time Differential Mössbauer Spectroscopy where the high time resolution in range of 176–200 ns is highly required. Technical concept of the TDMS is based on the virtual instrumentation technique and uses fast digital oscilloscope. Performance and detector utilization have been clarified by decreasing the Mössbauer spectral line-width of K{sub 2}MgFe(CN){sub 6} reference sample from 0.33 mm/s (integral mode) to 0.23 mm/s (time differential mode). This report also describes characterization and utilization of the detector together with additional electronic blocks and two-channel fast data-acquisition system construction.

  1. Highly effective portable beta spectrometer for precise depth selective electron Moessbauer spectroscopy

    International Nuclear Information System (INIS)

    Aldiyarov, N.U.; Kadyrzhanov, K.K.; Seytimbetov, A.M.; Zhdanov, V.S.

    2007-01-01

    Full text: More broad application of the nuclear-physical method of precise Depth Selective Electron Moessbauer Spectroscopy (DS EMS) is limited by insufficient accessibility of highly-effective beta spectrometers with acceptable resolution. It should be mentioned that the method DS EMS is realized at a combined installation that consists of a highly-effective beta spectrometer and a conventional portable nuclear gamma-resonance spectrometer. Yet few available beta spectrometers have sophisticated design and controlling; in most cases they are cumbersome. All the attempts to simplify beta spectrometers resulted in noticeable worsening of depth resolution for the DS EMS method making the measurements non precise. There is currently an obvious need in a highly-effective portable easily controlled beta spectrometer. While developing such portable beta spectrometer, it is more promising to use as basis a simpler spectrometer, which has ratio of sample size to spectrometer size of about five times. The paper presents an equal-arm version of a highly-effective portable beta spectrometer with transverse heterogeneous sector magnetic field that assures double focusing. The spectrometer is equipped with a large-area non-equipotential source (a sample under investigation) and a position-sensitive detector. This portable spectrometer meets all requirements for achievement of the DS EMS depth resolution close to the physical limit and demonstrates the following main characteristics: equilibrium orbit radius ρ 0 = 80 mm, instrumental energy resolution 0.6 % at solid angle 1 % of 4π steradian, area of non-equipotential source ∼ 80 mm 2 , registration by position-sensitive detector of ∼ 10 % of the energy interval. Highly-effective portable beta spectrometer assures obtaining Moessbauer data with depth resolution close to physical limit of the DS EMS method. So in measurements at conversion and Auger electrons with energies of about units of keV and above, the achieved

  2. Vector network analyzer ferromagnetic resonance spectrometer with field differential detection

    Science.gov (United States)

    Tamaru, S.; Tsunegi, S.; Kubota, H.; Yuasa, S.

    2018-05-01

    This work presents a vector network analyzer ferromagnetic resonance (VNA-FMR) spectrometer with field differential detection. This technique differentiates the S-parameter by applying a small binary modulation field in addition to the DC bias field to the sample. By setting the modulation frequency sufficiently high, slow sensitivity fluctuations of the VNA, i.e., low-frequency components of the trace noise, which limit the signal-to-noise ratio of the conventional VNA-FMR spectrometer, can be effectively removed, resulting in a very clean FMR signal. This paper presents the details of the hardware implementation and measurement sequence as well as the data processing and analysis algorithms tailored for the FMR spectrum obtained with this technique. Because the VNA measures a complex S-parameter, it is possible to estimate the Gilbert damping parameter from the slope of the phase variation of the S-parameter with respect to the bias field. We show that this algorithm is more robust against noise than the conventional algorithm based on the linewidth.

  3. The physical basis for estimating wave-energy spectra with the radar ocean-wave spectrometer

    Science.gov (United States)

    Jackson, Frederick C.

    1987-01-01

    The derivation of the reflectivity modulation spectrum of the sea surface for near-nadir-viewing microwave radars using geometrical optics is described. The equations required for the derivation are presented. The derived reflectivity modulation spectrum provides data on the physical basis of the radar ocean-wave spectrometer measurements of ocean-wave directional spectra.

  4. Gravitational Waves and Gamma-Rays from a Binary Neutron Star Merger: GW170817 and GRB 170817A

    DEFF Research Database (Denmark)

    Abbott, B. P.; Abbott, R.; Abbott, T. D.

    2017-01-01

    On 2017 August 17, the gravitational-wave event GW170817 was observed by the Advanced LIGO and Virgo detectors, and the gamma-ray burst (GRB) GRB 170817A was observed independently by the Fermi Gamma-ray Burst Monitor, and the Anti-Coincidence Shield for the Spectrometer for the International Gam...

  5. Mapping of radiation anomalies using UAV mini-airborne gamma-ray spectrometry.

    Science.gov (United States)

    Šálek, Ondřej; Matolín, Milan; Gryc, Lubomír

    2018-02-01

    Localization of size-limited gamma-ray anomalies plays a fundamental role in uranium prospecting and environmental studies. Possibilities of a newly developed mini-airborne gamma-ray spectrometric equipment were tested on a uranium anomaly near the village of Třebsko, Czech Republic. The measurement equipment was based on a scintillation gamma-ray spectrometer specially developed for unmanned aerial vehicles (UAV) mounted on powerful hexacopter. The gamma-ray spectrometer has two 103 cm 3 BGO scintillation detectors of relatively high sensitivity. The tested anomaly, which is 80 m by 40 m in size, was investigated by ground gamma-ray spectrometric measurement in a detail rectangular measurement grid. Average uranium concentration is 25 mg/kg eU attaining 700 mg/kg eU locally. The mini-airborne measurement across the anomaly was carried out on three 100 m long parallel profiles at eight flight altitudes from 5 to 40 m above the ground. The resulting 1 s 1024 channel gamma-ray spectra, recorded in counts per second (cps), were processed to concentration units of K, U and Th, while total count (TC) was reported in cps. Increased gamma ray intensity of the anomaly was indicated by mini-airborne measurement at all profiles and altitudes, including the highest altitude of 40 m, at which the recorded intensity is close to the natural radiation background. The reported instrument is able to record data with comparable quality as standard airborne survey, due to relative sensitive detector, lower flight altitude and relatively low flight speed of 1 m/s. The presented experiment brings new experience with using unmanned semi-autonomous aerial vehicles and the latest mini-airborne radiometric instrument. The experiment has demonstrated the instrument's ability to localize size-limited uranium anomalies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. A hard x-ray spectrometer for high angular resolution observations of cosmic sources

    International Nuclear Information System (INIS)

    Hailey, C.J.; Ziock, K.P.; Harrison, F.; Kahn, S.M.; Liedahl, D.; Lubin, P.M.; Seiffert, M.

    1988-01-01

    LAXRIS (large area x-ray imaging spectrometer) is an experimental, balloon-borne, hard x-ray telescope that consists of a coaligned array of x-ray imaging spectrometer modules capable of obtaining high angular resolution (1--3 arcminutes) with moderate energy resolution in the 20- to 300-keV region. Each spectrometer module consists of a CsI(Na) crystal coupled to a position-sensitive phototube with a crossed-wire, resistive readout. Imaging is provided by a coded aperture mask with a 4-m focal length. The high angular resolution is coupled with rather large area (/approximately/800 cm 2 ) to provide good sensitivity. Results are presented on performance and overall design. Sensitivity estimates are derived from a Monte-Carlo code developed to model the LAXRIS response to background encountered at balloon altitudes. We discuss a variety of observations made feasible by high angular resolution. For instance, spatially resolving the nonthermal x-ray emission from clusters of galaxies is suggested as an ideal program for LAXRIS. 15 refs., 5 figs

  7. Using the transportable, computer-operated, liquid-scintillator fast-neutron spectrometer system

    International Nuclear Information System (INIS)

    Thorngate, J.H.

    1988-01-01

    When a detailed energy spectrum is needed for radiation-protection measurements from approximately 1 MeV up to several tens of MeV, organic-liquid scintillators make good neutron spectrometers. However, such a spectrometer requires a sophisticated electronics system and a computer to reduce the spectrum from the recorded data. Recently, we added a Nuclear Instrument Module (NIM) multichannel analyzer and a lap-top computer to the NIM electronics we have used for several years. The result is a transportable fast-neutron spectrometer system. The computer was programmed to guide the user through setting up the system, calibrating the spectrometer, measuring the spectrum, and reducing the data. Measurements can be made over three energy ranges, 0.6--2 MeV, 1.1--8 MeV, or 1.6--16 MeV, with the spectrum presented in 0.1-MeV increments. Results can be stored on a disk, presented in a table, and shown in graphical form. 5 refs., 51 figs

  8. Characteristics of a gamma telescope on the ''Kosmos-561'' satellite

    International Nuclear Information System (INIS)

    Bokov, V.L.; Kruglov, E.M.

    1981-01-01

    The results of calculations of gamma telescope characteristics intended for investigating cosmic γ radiation at E>=100 MeV in the ''Cosmos 561'' artificial Earth satellite, using the Monte Carlo method, are presented. The gamma spectrometer contains a lead converter, scintillation deteectors of polysterene, a unit of spark chambers and a Cherenkov detector of lead glass. The dependence of the device effective area and angular resolution on γ quanta energy is calculated. The relative radiation pattern of the device is given. The given integral characteristics of the gamma telescope for a γ quanta flux with an exponential spectrum are the following: the effective geometrical factor and effective device area depending on the spectrum index. The calibration gamma telescope curve is plotted according to the electron mean free path distribution [ru

  9. Wavelength modulation spectroscopy of semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Kohn, S.E.

    1977-10-01

    The use of modulation spectroscopy to study the electronic properties of solids has been very productive. The construction of a wide range Wavelength Modulation Spectrometer to study the optical properties of solids is described in detail. Extensions of the working range of the spectrometer into the vacuum ultraviolet are discussed. Measurements of the reflectivity and derivative reflectivity spectra of the lead chalcogenides, the chalcopyrite ZnGeP/sub 2/, the layer compounds GaSe and GaS and their alloys, the ferroelectric SbSI, layer compounds SnS/sub 2/ and SnSe/sub 2/, and HfS/sub 2/ were made. The results of these measurements are presented along with their interpretation in terms of band structure calculations.

  10. Measurement of the pulse pileup correction for the HPGe gamma spectrometer

    International Nuclear Information System (INIS)

    Kulkarni, D.B.; Anuradha, R.; Joseph, Leena; Kulkarni, M.S.

    2018-01-01

    Radiation Standards Section (RSS), RSSD, has HPGe gamma spectrometry system maintained as a secondary standard for standardization of gamma emitting radionuclides. This system is also used to detect the impurities in the radioactivity samples supplied for the international inter-comparison exercises, so that the appropriate correction can be made for the standardized activity of principle radionuclide. The system is calibrated as per the recommended procedure (ANSI standard N42.14, 1999). As a part of this calibration, measurement of the pulse pile up correction was carried out in the energy range of 81 keV to 1408 keV. The measurement of pileup correction is very important for the standardization of sources having higher counting rates where the extent of the pileup effect is more and considerable deviation from the true counting rates was observed. For these sources the measured photo peak counting rate is less than true counting rate and needs to be corrected for pileup effect. The details of experiments are discussed in this paper

  11. Multiplicity and correlated energy of gamma rays emitted in the spontaneous fission of Californium-252

    International Nuclear Information System (INIS)

    Brunson, G.S. Jr.

    1982-06-01

    An array of eight high-speed plastic scintillation detectors has been used to infer a mathematical model for the emission multipliciy of prompt gammas in the spontaneous fission of 252 Cf. Exceptional time resolution and coincidence capability permitted the separation of gammas from fast neutrons over a flight path of approximately 10 cm. About 20 different distribution models were tested. The average energy of the prompt gammas is inversely related to the number emitted; however, this inverse relationship is not strong and the total gamma energy does increase with increasing gamma number. An extension of the experiment incorporated a lithium-drifted germanium gamma spectrometer that resolved nearly 100 discrete gammas associated with fission. Of these gammas, some were preferentially associated with fission in which few gammas were emitted. Certain others were more frequent when many gammas were emitted. Results are presented

  12. Seizure-induced alterations in fast-spiking basket cell GABA currents modulate frequency and coherence of gamma oscillation in network simulations

    International Nuclear Information System (INIS)

    Proddutur, Archana; Yu, Jiandong; Elgammal, Fatima S.; Santhakumar, Vijayalakshmi

    2013-01-01

    was depolarizing (−54 mV). When FS-BCs were activated by biologically based dendritic synaptic inputs, enhancing g GABA-extra reduced the frequency and coherence of FS-BC firing when E GABA was shunting and increased average FS-BC firing when E GABA was depolarizing. Shifting E GABA from shunting to depolarizing potentials consistently increased network frequency to and above high gamma frequencies (>80 Hz). Since gamma oscillations may contribute to learning and memory processing [Fell et al., Nat. Neurosci. 4, 1259 (2001); Jutras et al., J. Neurosci. 29, 12521 (2009); Wang, Physiol. Rev. 90, 1195 (2010)], our demonstration that network oscillations are modulated by extrasynaptic inhibition in FS-BCs suggests that neuroactive compounds that act on extrasynaptic GABA receptors could impact memory formation by modulating hippocampal gamma oscillations. The simulation results indicate that the depolarized FS-BC GABA reversal, observed after experimental seizures, together with enhanced spillover extrasynaptic GABA currents are likely to promote generation of focal high frequency activity associated with epileptic networks

  13. Light collection and its fluctuation in Cherenkov and scintillation spectrometers

    International Nuclear Information System (INIS)

    Kitaev, D.F.; Samedov, V.V.; Stolyarova, E.L.

    1982-01-01

    The GAMMA program for calculating light collection in the Cherenkov and scintillation counters is described. Together with the shower modelling program the GAMNA program can be used for evaluating the output signal and energy resolution of shower spectrometers. Principle formulae and block diagram of the program are given. Results of test calculations performed on the example of scintillation counters of culindrical and rectangular shapes were considered. Modelling of the radiation polarization envisaged in the program permits to take account of the effect of selective discrimination of photoelectron amplifier photocathode. The program analyzes, for the present situation, calculation errors which permits to plan in advance the calculation with the given accuracy. The program permits to use additional subprograms together with it where it is possible to take account of other peculiarities of light collection, for example, the presence of outer reflectors and focusing elements of light collection systems, particle slowing down in the spectrometer radiator expressed in the change of angle of semiaperture of the Cherenkov radiation cone. It is concluded on the basis of analyzing results of test calculations that the choosen technique and algorithms of light collection coefficient calculation in spectrometer radiators are correct

  14. CAMAC gamma ray scanning system

    International Nuclear Information System (INIS)

    Moss, C.E.; Pratt, J.C.; Shunk, E.R.

    1981-01-01

    A flexible gamma-ray scanning system, based on a LeCroy 3500 multichannel analyzer and CAMAC modules, is described. The system is designed for making simultaneous passive and active scans of objects of interest to nuclear safeguards. The scanner is a stepping-motor-driven carriage; the detectors, a bismuth-germanate scintillator and a high-purity germanium detector. A total of sixteen peaks in the two detector-produced spectra can be integrated simultaneously, and any scan can be viewed during data acquisition. For active scanning, the 2615-keV gamma-ray line from a 232 U source and the 4439-keV gamma-ray line from 9 Be(α,n) 12 C were selected. The system can be easily reconfigured to accommodate up to seven detectors because it is based on CAMAC modules and FORTRAN. The system is designed for field use and is easily transported. Examples of passive and active scans are presented

  15. Laboratory calibrations of airborne gamma-ray spectrometers. Measurements and discussions of important parameters

    International Nuclear Information System (INIS)

    Korsbech, U.

    1994-02-01

    This report is the fourth of reports from The Department of Electrophysics covering measurement and interpretation of airborne gamma-spectrometry measurements. It describes different topics concerning the construction of a suitable calibration setup in the laboratory. The goal is to build a simple and cheap laboratory setup that can produce most of the gamma-ray data needed for an interpretation of spectra measured 50 to 120 m above ground level. A simple calibration setup has been build and tested. It may produce gamma-ray spectra similar to those measured in the air - from surface contamination with artificial nuclides and from 'bulk' natural radioactivity. It is possible to investigate the influence of the air above an aircraft carrying the detector (skyshine: scattering of gamma photons in the air above the detector). In order to reduce the influence of non-detected pile-up the count rates are kept low without reaching levels where the background spectra (to be subtracted) would cause unacceptable counting statistical fluctuations. Sources selected for the calibrations are heavy minerals sand (with thorium and uranium), potassium nitrate (with 40 K). These sources are 'bulk sources' of natural radioactivity. Cesium-137 has been selected as the basic artifical surface contamination nuclide. The report also discusses methods for comparing two spectra a priori assumed equal. Finally the properties of some materials that could be used as 'air-substitutes' in the calibration setup have been tested with respect to stability against moisture sorption. (au)

  16. The Study of Radiation of Gamma-Ray Background at Sedimentology Laboratorium, P3TIR, BATAN, Using Gamma Spectrometry

    International Nuclear Information System (INIS)

    Lubis, Ali Arman; Aliyanta, Barokah; Darman

    2002-01-01

    The measurement of background radiation of gamma-ray has been done at Sedimentology Laboratory, SDAL building, P3TIR, BATAN using gamma spectrometer. The measurement was done without shielding with the range of energy between 50 keV and 1500 keV. The identified radiations are coming from environmental radionuclide and man-made radionuclide as well with 32 energy peaks. The environmental radionuclides are from Uranium series, Thorium series, and 4 0 K having dose rate of 12.510 ± O.980, 36.408 ± 3.243, 9.455 ±O.016 n Sv/day, respectively, whilst man-made radionuclide is 6 O C o having dose rate of O.136 ±O.078 n Sv/day

  17. Advanced techniques for high resolution spectroscopic observations of cosmic gamma-ray sources

    International Nuclear Information System (INIS)

    Matteson, J.L.; Pelling, M.R.; Peterson, L.E.

    1985-08-01

    We describe an advanced gamma-ray spectrometer that is currently in development. It will obtain a sensitivity of -4 ph/cm -2 -sec in a 6 hour balloon observation and uses innovative techniques for background reduction and source imaging

  18. GRAB - WRS system module number 60221 for calculating gamma-ray penetration in slab shields by the method of kernel integration with build-up factors

    International Nuclear Information System (INIS)

    Grimstone, M.J.

    1978-06-01

    The WRS Modular Programming System has been developed as a means by which programmes may be more efficiently constructed, maintained and modified. In this system a module is a self-contained unit typically composed of one or more Fortran routines, and a programme is constructed from a number of such modules. This report describes one WRS module, the function of which is to calculate the gamma-ray flux, dose, or heating rate in a slab shield using the build-up factor method. The information given in this manual is of use both to the programmer wishing to incorporate the module in a programme, and to the user of such a programme. (author)

  19. Neutron and gamma-ray spectra of {sup 239}PuBe and {sup 241}AmBe

    Energy Technology Data Exchange (ETDEWEB)

    Vega-Carrillo, H.R. E-mail: rvega@cantera.reduaz.mx; Manzanares-Acuna, Eduardo; Becerra-Ferreiro, A.M.; Carrillo-Nunez, Aureliano

    2002-08-01

    Neutron and gamma-ray spectra of {sup 239}PuBe and {sup 241}AmBe were measured and their dosimetric features were calculated. Neutron spectra were measured using a multisphere neutron spectrometer with a {sup 6}LiI(Eu) scintillator. The {sup 239}PuBe neutron spectrum was measured in an open environment, while the {sup 241}AmBe neutron spectrum was measured in a closed environment. Gamma-ray spectra were measured using a NaI(Tl) scintillator using the same experimental conditions for both sources. The effect of measuring conditions for the {sup 241}AmBe neutron spectrum indicates the presence of epithermal and thermal neutrons. The low-resolution neutron spectra obtained with the multisphere spectrometer allows one to calculate the dosimetric features of neutron sources. At 100 cm both sources produce approximately the same count rate as that of the 4.4 MeV gamma-ray per unit of alpha emitter activity.

  20. Use of two monoenergetic gamma-ray attenuation method in wood samples

    International Nuclear Information System (INIS)

    Mortatti, J.; Nascimento Filho, V.F. do; Barros Ferraz, E.S. de

    1983-01-01

    The mass attenuation coefficients for 10 wood species were determined employing the gamma attenuation technique with a single beam comprising two monoenergetics gamma energies from 137 Cs/sup(137m) Ba and 141 Am (662 and 59,6 KeV, respectively). The absorbed radiation was simultaneously measured by means of a 3'' x 3'' Nal (T1) planar solid scintillator crystal connected to a two channel gamma spectrometer. The effect of the 137 Cs/ sup(137m) Ba compton radiation on the not 241 Am counting rates were corrected. Dead time effects were desregarded, as the counting rates were always below 10 5 cpm. (Author) [pt

  1. Role of Vitamin E and/or High Protein Diet in Modulating Antioxidant Status and Certain Biochemical Changes in Gamma-Irradiated Rats

    International Nuclear Information System (INIS)

    Hamza, R.G.; El-Shennawy, H.M.

    2009-01-01

    The main purpose of this study was to examine the modulator effect of vitamin E and/ or high protein diet on the gamma irradiation induced changes in antioxidant Status and certain biochemical parameters. Male albino rats were exposed to 6 Gy (single dose: 0.48 Gy/min) of whole body gamma radiation. Vitamin E (50 mg/kg body weight) was daily administrated to rats via stomach tube for 3 weeks before exposure to gamma radiation continued for 3 weeks post irradiation. Other animals fed daily on high protein diet for 3 weeks before irradiation continued for 3 weeks post irradiation. A combined administration of vitamin E and Feeding on high protein diet was daily applied to another rats group for 3 weeks before irradiation continued for 3 weeks post irradiation. The results obtained revealed that the administration of vitamin E and/or feeding on high protein diet were significantly reduced the changes. induced by gamma irradiation in blood antioxidant enzymes activities (Superoxide dismutase: SOD and Catalase; CAT). concentration of reduced glutathione (GSH). Significant amelioration in the plasma level of total cholesterol (TC), triglycerides (TG), Low density lipoprotein cholesterol (LDL-C) and High density lipoprotein-cholesterol (HDL-C) associated with remarkable decrease in the level of malondialdhyde (MDA) were observed. In addition, significant improvements were observed in liver function parameters (activities of serum aminotransferases (AST, ALT), alkaline phosphatase (ALP) and concentration of total protein and globulin. As well as, the changes in kidney function (serum creatinine and urea levels) were significantly improved. The improvements also extended to include the serum level of uric acid. Accordingly, it could be concluded that. via the adjustment of the antioxidant status, decreasing the releasing of lipid peroxides and the subsequent amending of different biochemical pathways. vitamin E and high protein diet could modulate the radiation injuries in

  2. Nuclear quadrupole resonance spectrometer for chlorine compounds

    International Nuclear Information System (INIS)

    Lasanda, J.

    1976-01-01

    An NQR spectrometer is described based on a superregenerative oscillator for high sensitivity. The application of a Pound-Knight type oscillator using field effect transistors resulted in higher stability of oscillation amplitude in the desired range of 10 to 50 MHz. The use of a current source allowed to set good signal-to-noise ratio independently of the amplitude of oscillations. For synchronizing of both oscillators a balanced modulator was used. (author)

  3. A broadband gamma-ray spectrometry using novel unfolding algorithms for characterization of laser wakefield-generated betatron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Jong Ho, E-mail: jhjeon07@ibs.re.kr; Nakajima, Kazuhisa, E-mail: naka115@dia-net.ne.jp; Pathak, Vishwa Bandhu; Cho, Myung Hoon; Yoo, Byung Ju; Shin, Kang Woo [Center for Relativistic Laser Science, Institute for Basic Science (IBS), Gwangju 500-712 (Korea, Republic of); Kim, Hyung Taek; Sung, Jae Hee; Lee, Seung Ku; Choi, Il Woo [Center for Relativistic Laser Science, Institute for Basic Science (IBS), Gwangju 500-712 (Korea, Republic of); Advanced Photonics Research Institute, GIST, Gwangju 500-712 (Korea, Republic of); Rhee, Yong Joo [Nuclear Data Center, Korea Atomic Energy Research Institute, Daejeon 305-353 (Korea, Republic of); Shin, Jung Hun; Jo, Sung Ha [Advanced Photonics Research Institute, GIST, Gwangju 500-712 (Korea, Republic of); Hojbota, Calin; Cho, Byeoung Ick; Nam, Chang Hee [Center for Relativistic Laser Science, Institute for Basic Science (IBS), Gwangju 500-712 (Korea, Republic of); Department of Physics and Photon Science, GIST, Gwangju 500-712 (Korea, Republic of)

    2015-12-15

    We present a high-flux, broadband gamma-ray spectrometry capable of characterizing the betatron radiation spectrum over the photon energy range from 10 keV to 20 MeV with respect to the peak photon energy, spectral bandwidth, and unique discrimination from background radiations, using a differential filtering spectrometer and the unfolding procedure based on the Monte Carlo code GEANT4. These properties are experimentally verified by measuring betatron radiation from a cm-scale laser wakefield accelerator (LWFA) driven by a 1-PW laser, using a differential filtering spectrometer consisting of a 15-filter and image plate stack. The gamma-ray spectra were derived by unfolding the photostimulated luminescence (PSL) values recorded on the image plates, using the spectrometer response matrix modeled with the Monte Carlo code GEANT4. The accuracy of unfolded betatron radiation spectra was assessed by unfolding the test PSL data simulated with GEANT4, showing an ambiguity of less than 20% and clear discrimination from the background radiation with less than 10%. The spectral analysis of betatron radiation from laser wakefield-accelerated electron beams with energies up to 3 GeV revealed radiation spectra characterized by synchrotron radiation with the critical photon energy up to 7 MeV. The gamma-ray spectrometer and unfolding method presented here facilitate an in-depth understanding of betatron radiation from LWFA process and a novel radiation source of high-quality photon beams in the MeV regime.

  4. FERMI LAT OBSERVATIONS OF LS I +610303: FIRST DETECTION OF AN ORBITAL MODULATION IN GeV GAMMA RAYS

    International Nuclear Information System (INIS)

    Abdo, A. A.; Ackermann, M.; Ajello, M.; Bechtol, K.; Berenji, B.; Blandford, R.; Bloom, E. D.; Borgland, A. W.; Atwood, W. B.; Axelsson, M.; Baldini, L.; Bellazzini, R.; Bregeon, J.; Brez, A.; Ballet, J.; Barbiellini, G.; Bastieri, D.; Baughman, B. M.; Bonamente, E.; Brigida, M.

    2009-01-01

    This Letter presents the first results from the observations of LS I +61 0 303 using Large Area Telescope data from the Fermi Gamma-Ray Space Telescope between 2008 August and 2009 March. Our results indicate variability that is consistent with the binary period, with the emission being modulated at 26.6 ± 0.5 days. This constitutes the first detection of orbital periodicity in high-energy gamma rays (20 MeV-100 GeV, HE). The light curve is characterized by a broad peak after periastron, as well as a smaller peak just before apastron. The spectrum is best represented by a power law with an exponential cutoff, yielding an overall flux above 100 MeV of 0.82 ± 0.03(stat) ± 0.07(syst) 10 -6 ph cm -2 s -1 , with a cutoff at 6.3 ± 1.1(stat) ± 0.4(syst) GeV and photon index Γ = 2.21 ± 0.04(stat) ± 0.06(syst). There is no significant spectral change with orbital phase. The phase of maximum emission, close to periastron, hints at inverse Compton scattering as the main radiation mechanism. However, previous very high-energy gamma ray (>100 GeV, VHE) observations by MAGIC and VERITAS show peak emission close to apastron. This and the energy cutoff seen with Fermi suggest that the link between HE and VHE gamma rays is nontrivial.

  5. Modulation of Enzymatic Activities of Dual Functional Peroxiredoxin by Gamma Irradiation

    International Nuclear Information System (INIS)

    Hong, Sung Hyun; Lee, Seung Sik; Park, Chul Hong; Chung, Byung Yeoup

    2012-01-01

    Recently, enzymes have frequently been used as catalysts in various bio-industrial, commercial, and pharmaceutical applications, because they are more stable, more efficient, and less toxic than the synthetic catalysts. However, one of their major disadvantages is their low thermostability, which leads the researchers to develop new forms of industrially important enzymes with increased resistance to inactivation and aggregation. This study describes a strategy for modifying the molecular chaperone activity of peroxiredoxin (Prx) by using gamma irradiation. Prxs are a ubiquitous family of antioxidant enzymes. Upon oxidation of their peroxidatic Cys, the molecules undergo a structural conversion from a low-molecular-weight (LMW) species acting as a peroxidase to a high-molecular-weight (HMW) complex functioning as a chaperone. In the present study, we examined the effect of gamma irradiation on PP1084 with respect to its protein structure and enzymatic function. The use of gamma irradiation as a physical treatment can increase the cohesive strength of the protein by forming cross-links. The aims of the present work were (1) to improve the chaperone activity of PP1084 by gamma irradiation, (2) to identify the 'optimal' intensity of gamma irradiation, and (3) to investigate the influence of gamma irradiation on protein hydrophobicity as related to chaperone function. Following PP1084 treatment with 30 kGy gamma irradiation, the PP1084 chaperone activity enhanced by about 3-4-fold compared with nonirradiated PP1084, while the peroxidase activity decreased. Ongoing research efforts are addressing the physical modifications of PP1084 protein by gamma irradiation

  6. Spherical grating spectrometers

    Science.gov (United States)

    O'Donoghue, Darragh; Clemens, J. Christopher

    2014-07-01

    We describe designs for spectrometers employing convex dispersers. The Offner spectrometer was the first such instrument; it has almost exclusively been employed on satellite platforms, and has had little impact on ground-based instruments. We have learned how to fabricate curved Volume Phase Holographic (VPH) gratings and, in contrast to the planar gratings of traditional spectrometers, describe how such devices can be used in optical/infrared spectrometers designed specifically for curved diffraction gratings. Volume Phase Holographic gratings are highly efficient compared to conventional surface relief gratings; they have become the disperser of choice in optical / NIR spectrometers. The advantage of spectrometers with curved VPH dispersers is the very small number of optical elements used (the simplest comprising a grating and a spherical mirror), as well as illumination of mirrors off axis, resulting in greater efficiency and reduction in size. We describe a "Half Offner" spectrometer, an even simpler version of the Offner spectrometer. We present an entirely novel design, the Spherical Transmission Grating Spectrometer (STGS), and discuss exemplary applications, including a design for a double-beam spectrometer without any requirement for a dichroic. This paradigm change in spectrometer design offers an alternative to all-refractive astronomical spectrometer designs, using expensive, fragile lens elements fabricated from CaF2 or even more exotic materials. The unobscured mirror layout avoids a major drawback of the previous generation of catadioptric spectrometer designs. We describe laboratory measurements of the efficiency and image quality of a curved VPH grating in a STGS design, demonstrating, simultaneously, efficiency comparable to planar VPH gratings along with good image quality. The stage is now set for construction of a prototype instrument with impressive performance.

  7. Fast neutron scintillation spectrometer in a heavy ion accelerator

    International Nuclear Information System (INIS)

    Blinov, M.V.; Gavrilov, B.P.; Ivannikova, L.L.; Kozulin, Eh.M.; Mozhaev, A.N.; Tyurin, G.P.

    1984-01-01

    Scintillation fast neutron spectrometer in a heavy ion accelerator is described in short. The spectrometer is used to measure characteristics of neutrons emitted in heavy ion interaction with different nuclei. Experiment was performed on the base of particle flight from 0.7 up to 2 m. Within the angle range of 0-150 deg. The technique is based on recording of two-dimensional neutron spectra obtained due to combination of the time-of-flight method and the method of recoil proton energy detection. Two measuring channels were used in the spectrometer. Each channel comprise both amplitude and time tracks. Detector on the base microchannel plates (MCP) generated a signal in passing the next ion bunch was used in order to obtain the time mark. Data from the scintillation block are recorded with respect to three parameters: recoil proton amplitude, time of neutron or γ-quantum arrival in respect of MCP-sensor pulse. Apparatus is carried out within the CAMAC standard. The spectrometer calibration within the 1-20 MeV neutron range was conducted in the Van-de-Graaf accelerator, and for higher energies - with the use of lightguides. Spectrometer time resolution for neutron energies of 0.5-50 MeV constituted 1.5-1.8 ns. The above measuring of neutron spectra from 1 /H2C+ 181 Ta and sup(20, 22)Ne+sup(181)Ta reaction have revealed a possibility of the experiment organization in heavy ion accelerators in the presence of strong neutron and γ-fields. Organization of multi-dimensional analysis combining two methods allows one to separate accelerator cycle, a region of the most reliable information, free of a low-energy gamma background and limited both by a dynamic threshold and a region of permissible energy values

  8. Advances in gamma ray resonant scattering and absorption long-lived isomeric nuclear states

    CERN Document Server

    Davydov, Andrey V

    2015-01-01

    This book presents the basics and advanced topics of research of gamma ray physics. It describes measuring of  Fermi surfaces with gamma resonance spectroscopy and the theory of angular distributions of resonantly scattered gamma rays. The dependence of excited-nuclei average lifetime on the shape of the exciting-radiation spectrum and electron binding energies in the spectra of scattered gamma rays is described. Resonant excitation by gamma rays of nuclear isomeric states with long lifetime leads to the emission and absorption lines. In the book, a new gamma spectroscopic method, gravitational gamma spectrometry, is developed. It has a resolution hundred million times higher than the usual Mössbauer spectrometer. Another important topic of this book is resonant scattering of annihilation quanta by nuclei with excited states in connection with positron annihilation. The application of the methods described is to explain the phenomenon of Coulomb fragmentation of gamma-source molecules and resonant scatt...

  9. Review of superconducting transition-edge sensors for x-ray and gamma-ray spectroscopy

    International Nuclear Information System (INIS)

    Ullom, Joel N; Bennett, Douglas A

    2015-01-01

    We present a review of emerging x-ray and gamma-ray spectrometers based on arrays of superconducting transition-edge sensors (TESs). Special attention will be given to recent progress in TES applications and in understanding TES physics. (paper)

  10. Quantifying the benefits of ultrahigh energy resolution for Gamma-ray spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Drury, Owen B.; Terracol, Stephane F.; Friedrich, Stephan [Advanced Detector Group, Lawrence Livermore National Laboratory, L-270, Livermore CA 94550 (United States)

    2005-03-01

    Cryogenic Gamma-ray spectrometers operating at temperatures of {proportional_to}0.1 K provide an order of magnitude better energy resolution than conventional germanium detectors. Ultra-high energy resolution improves the accuracy of non-destructive analysis of nuclear materials, since a better separation of lines reduces statistical errors as well as systematic errors from background subtraction and efficiency correction. We are developing cryogenic Gamma-spectrometers based on bulk tin absorbers and superconducting molybdenum-copper sensors for nuclear forensics and non-proliferation applications. Here we quantify the improvements in accuracy for isotope analysis with cryogenic detectors in terms of detector performance for different cases of line separation, line intensity ratios and background levels. Precise measurements of isotope ratios are crucial in the context of nuclear attribution, since they provide signatures of composition, age, origin, intended purpose and processing history of illicit nuclear materials. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  11. An in-beam Compton-suppressed Ge spectrometer for nondestructive neutron activation analysis

    International Nuclear Information System (INIS)

    Zaghloul, R.; Abd El-Haleam, A.; Mostafa, M.; Gantner, E.; Ache, H.J.

    1993-04-01

    A high-efficiency compton background suppressed gamma-ray spectrometer by anti-coincidence counting with a NaI(Tl)-shield around a central HPGe-detector for in-beam prompt gamma-ray neutron activation analysis (AC-PGNAA) using a Cf-252 neutron source has been designed and built to provide simultaneous anti-coincidence spectrometry of natural, industrial and environmental samples. The spectrometer consists of a high-purity germanium detector as the main detector and a large volume cylindrical NaI(Tl) detector as a guard detector. The assembly has the ability to measure instantaneously, simultaneously and nondestructively bulk samples up to about 50 cm 3 . Major constituent elements in several rocks and minerals such as H, B, N, Na, Mg, Al, Si, Cl, K, Ca, P, S, Ti, Fe, Sm, Nd, Mn and Gd can be determined, while oxygen cannot be measured due to its small capture cross section (0.27 mb). Several important minor and trace elements such as B, Cd and Hg beside the low residual activity, rare earths and short-lived isotopes could be detected. The sensitivity of the AC-PGNAA technique is limited by the available neutron flux at the target matrix and the neutron absorption cross section of the elements of interest. PGNAA has the advantage to estimate the constituent elements which are difficult to be measured through the delayed gamm-ray measurements such as B, Bi, C, H, P, Tl, Be, Cl and S in industrial and reference materials and those elements which are transformed into other stable isotopes when undergoing neutron capture. The design of the spectrometer assembly, its properties and performance are described

  12. GammaCHI: a package for the inversion and computation of the gamma and chi-square cumulative distribution functions (central and noncentral)

    NARCIS (Netherlands)

    A. Gil (Amparo); J. Segura (Javier); N.M. Temme (Nico)

    2015-01-01

    textabstractA Fortran 90 module GammaCHI for computing and inverting the gamma and chi-square cumulative distribution functions (central and noncentral) is presented. The main novelty of this package is the reliable and accurate inversion routines for the noncentral cumulative distribution

  13. Fission physics experiments at the time-of-flight spectrometer GNEIS in Gatchina (PNPI)

    International Nuclear Information System (INIS)

    Shcherbakov, O.A.

    1994-01-01

    The outline of and fission physics experiments at the Gatchina neutron spectrometer GNEIS based on the 1 GeV PNPI proton synchrotron are presented. The prefission gamma-ray spectrum of the (n, gamma f) reaction were investigated. The capture gamma-ray spectra for 721.6 eV and 1211.4 eV resonances in U-238 were measured and the nature of the 721.6 eV resonance in U-238 were examined. The forward-backward asymmetry in slow neutron fission of U-235 and energy dependence of the forward-backward and instrumental asymmetry coefficients were obtained. Fission cross section ratios for Th-232 to U-235 and for U-238 to U-235 in the energy range up to 200 MeV were measured. The results of the cross section ratios agreed well with those of Behrens et al. and Difilippo et al. (T.H.)

  14. A low-cost spectrometer for NMR measurements in the Earth's magnetic field

    International Nuclear Information System (INIS)

    Michal, Carl A

    2010-01-01

    We describe and demonstrate an inexpensive, easy-to-build, portable spectrometer for nuclear magnetic resonance measurements in the Earth's magnetic field. The spectrometer is based upon a widely available inexpensive microcontroller, which acts as a pulse programmer, audio-frequency synthesizer and digitizer, replacing what are typically the most expensive specialized components of the system. The microcontroller provides the capability to execute arbitrarily long and complicated sequences of phase-coherent, phase-modulated excitation pulses and acquire data sets of unlimited duration. Suitably packaged, the spectrometer is amenable to measurements in the research lab, in the field or in the teaching lab. The choice of components was heavily weighted by cost and availability, but required no significant sacrifice in performance. Using an existing personal computer, the resulting design can be assembled for as little as US$200. The spectrometer performance is demonstrated with spin-echo and Carr–Purcell–Meiboom–Gill pulse sequences on a water sample

  15. A low-cost spectrometer for NMR measurements in the Earth's magnetic field

    Science.gov (United States)

    Michal, Carl A.

    2010-10-01

    We describe and demonstrate an inexpensive, easy-to-build, portable spectrometer for nuclear magnetic resonance measurements in the Earth's magnetic field. The spectrometer is based upon a widely available inexpensive microcontroller, which acts as a pulse programmer, audio-frequency synthesizer and digitizer, replacing what are typically the most expensive specialized components of the system. The microcontroller provides the capability to execute arbitrarily long and complicated sequences of phase-coherent, phase-modulated excitation pulses and acquire data sets of unlimited duration. Suitably packaged, the spectrometer is amenable to measurements in the research lab, in the field or in the teaching lab. The choice of components was heavily weighted by cost and availability, but required no significant sacrifice in performance. Using an existing personal computer, the resulting design can be assembled for as little as US200. The spectrometer performance is demonstrated with spin-echo and Carr-Purcell-Meiboom-Gill pulse sequences on a water sample.

  16. Seizure-induced alterations in fast-spiking basket cell GABA currents modulate frequency and coherence of gamma oscillation in network simulations

    Energy Technology Data Exchange (ETDEWEB)

    Proddutur, Archana; Yu, Jiandong; Elgammal, Fatima S. [Department of Neurology and Neurosciences, New Jersey Medical School, Rutgers, Newark, New Jersey 07103 (United States); Santhakumar, Vijayalakshmi, E-mail: santhavi@njms.rutgers.edu [Department of Neurology and Neurosciences, New Jersey Medical School, Rutgers, Newark, New Jersey 07103 (United States); Department of Pharmacology and Physiology, New Jersey Medical School, Rutgers, Newark, New Jersey 07103 (United States)

    2013-12-15

    FS-BC frequency when E{sub GABA} was depolarizing (−54 mV). When FS-BCs were activated by biologically based dendritic synaptic inputs, enhancing g{sub GABA-extra} reduced the frequency and coherence of FS-BC firing when E{sub GABA} was shunting and increased average FS-BC firing when E{sub GABA} was depolarizing. Shifting E{sub GABA} from shunting to depolarizing potentials consistently increased network frequency to and above high gamma frequencies (>80 Hz). Since gamma oscillations may contribute to learning and memory processing [Fell et al., Nat. Neurosci. 4, 1259 (2001); Jutras et al., J. Neurosci. 29, 12521 (2009); Wang, Physiol. Rev. 90, 1195 (2010)], our demonstration that network oscillations are modulated by extrasynaptic inhibition in FS-BCs suggests that neuroactive compounds that act on extrasynaptic GABA receptors could impact memory formation by modulating hippocampal gamma oscillations. The simulation results indicate that the depolarized FS-BC GABA reversal, observed after experimental seizures, together with enhanced spillover extrasynaptic GABA currents are likely to promote generation of focal high frequency activity associated with epileptic networks.

  17. A search for spectral lines in gamma-ray bursts using TGRS

    International Nuclear Information System (INIS)

    Kurczynski, P.; Palmer, D.; Seifert, H.; Teegarden, B. J.; Gehrels, N.; Cline, T. L.; Ramaty, R.; Hurley, K.; Madden, N. W.; Pehl, R. H.

    1998-01-01

    We present the results of an ongoing search for narrow spectral lines in gamma-ray burst data. TGRS, the Transient Gamma-Ray Spectrometer aboard the Wind satellite is a high energy-resolution Ge device. Thus it is uniquely situated among the array of space-based, burst sensitive instruments to look for line features in gamma-ray burst spectra. Our search strategy adopts a two tiered approach. An automated 'quick look' scan searches spectra for statistically significant deviations from the continuum. We analyzed all possible time accumulations of spectra as well as individual spectra for each burst. Follow-up analysis of potential line candidates uses model fitting with F-test and χ 2 tests for statistical significance

  18. Rapid, Time-Division Multiplexed, Direct Absorption- and Wavelength Modulation-Spectroscopy

    Directory of Open Access Journals (Sweden)

    Alexander Klein

    2014-11-01

    Full Text Available We present a tunable diode laser spectrometer with a novel, rapid time multiplexed direct absorption- and wavelength modulation-spectroscopy operation mode. The new technique allows enhancing the precision and dynamic range of a tunable diode laser absorption spectrometer without sacrificing accuracy. The spectroscopic technique combines the benefits of absolute concentration measurements using calibration-free direct tunable diode laser absorption spectroscopy (dTDLAS with the enhanced noise rejection of wavelength modulation spectroscopy (WMS. In this work we demonstrate for the first time a 125 Hz time division multiplexed (TDM-dTDLAS-WMS spectroscopic scheme by alternating the modulation of a DFB-laser between a triangle-ramp (dTDLAS and an additional 20 kHz sinusoidal modulation (WMS. The absolute concentration measurement via the dTDLAS-technique allows one to simultaneously calibrate the normalized 2f/1f-signal of the WMS-technique. A dTDLAS/WMS-spectrometer at 1.37 µm for H2O detection was built for experimental validation of the multiplexing scheme over a concentration range from 50 to 3000 ppmV (0.1 MPa, 293 K. A precision of 190 ppbV was achieved with an absorption length of 12.7 cm and an averaging time of two seconds. Our results show a five-fold improvement in precision over the entire concentration range and a significantly decreased averaging time of the spectrometer.

  19. Integration and Evaluation of a Position Sensor with Continuous Read-Out for use with the Environmental Measurement-While-Drilling Gamma Ray Spectrometer System

    International Nuclear Information System (INIS)

    Lockwood, G.J.; Normann, R.A.; Selph, M.M.; Williams, C.V.

    1999-01-01

    The Environmental Measurement-While-Drilling-Gamma Ray Spectrometer (EMWD-GRS) system represents an innovative blend of new and existing technology that provides real-time environmental and drill bit data during drilling operations. The EMWD-GRS technology was demonstrated at Savannah River Site (SRS) F-Area Retention Basin. The EMWD-GRS technology demonstration consisted of continuously monitoring for gamma-radiation-producing contamination while drilling two horizontal boreholes below the backfilled waste retention basin. These boreholes passed near previously sampled locations where concentrations of contaminant levels of cesium had been measured. Contaminant levels continuously recorded by the EMWD-GRS system during drilling were compared to contaminant levels previously determined through quantitative laboratory analysis of soil samples. The demonstration of the EMWD-GRS was a complete success. The results show general agreement between the soil sampling and EMWD-GRS techniques for CS-137. It was recognized that the EMWD-GRS tool would better satisfy our customers' needs if the instrument location could be continuously monitored. During the demonstration at SRS, an electromagnetic beacon with a walkover monitor (Subsitereg s ign) was used to measure bit location at depth. To use a beacon locator drilling must be stopped, thus it is normally only used when a new section of pipe was added. The location of contamination could only be estimated based on the position of the EMED-GRS package and the distance between locator beacon readings. A continuous location system that would allow us to know the location of each spectrum as it is obtained is needed

  20. A 16-detector alpha spectrometer using 1 multichannel analyzer

    International Nuclear Information System (INIS)

    Phillips, W.G.

    1978-01-01

    An alpha spectrometer containing 16 independent detectors and utilizing one 4096-channel multichannel analyzer (MCA) was constructed from commerically available modules. The spectrometer was designed specifically for the counting of low levels of radioactivity in environmental samples. Gated analog routing allows spectral data acquisition into 256 channel regions of the MCA memory as if each region were an independent 256-channel MCA. External live-time clocks and 50-Mhz analog-to-digital converters control timing and acquisition on each unit of eight detectors. Spectral data output is to magnetic tape in units of 256 channels each with a unique tagword. These tapes are then read and processed, and final reports are generated, by a large Control Data 6000 series computer

  1. Correlation spectrometer

    Science.gov (United States)

    Sinclair, Michael B [Albuquerque, NM; Pfeifer, Kent B [Los Lunas, NM; Flemming, Jeb H [Albuquerque, NM; Jones, Gary D [Tijeras, NM; Tigges, Chris P [Albuquerque, NM

    2010-04-13

    A correlation spectrometer can detect a large number of gaseous compounds, or chemical species, with a species-specific mask wheel. In this mode, the spectrometer is optimized for the direct measurement of individual target compounds. Additionally, the spectrometer can measure the transmission spectrum from a given sample of gas. In this mode, infrared light is passed through a gas sample and the infrared transmission signature of the gasses present is recorded and measured using Hadamard encoding techniques. The spectrometer can detect the transmission or emission spectra in any system where multiple species are present in a generally known volume.

  2. The use of car-borne gamma-ray spectrometric survey in a basin

    International Nuclear Information System (INIS)

    Liu Tengyao; Lu Shili; Luo Zongquan.

    1985-01-01

    This paper describes the geological results in a basin in the Inner Mongolia which were obtained by using our newly-developed and assembled car-borne gamma-ray spectrometric system. Combined with the work of regional geology and remote sensing, five relatively favourable uranium zones were located within the working area. The field procedures of car-borne gamma-ray spectrometry for less rigid regions is discussed. The gamma-ray spectrometric profiling is mainly used for regional reconnaissance. In the case of enhanced anomalious radioactivity the profiling with varying directions is adopted and the data are plotted on scale 1:50000 topographic map. It is suggested that the car-borne gamma-ray spectrometric system can be calibrated both by the pads specified for portable spectrometers and by testing site when the calibration facility for the car-borne gamma-ray spectrometric system is not available. The effect of rainfall on car-borne gamma-ray spectrometric survey and the simplified field qualitative determination of U-Ra disequilibrium are also briefly discussed

  3. The muon spectrometer of the L3 detector at LEP

    International Nuclear Information System (INIS)

    Peng, Y.

    1988-01-01

    In this thesis the construction of the muon spectrometer of the L3 detector is described, one of the four detectors presently being prepared for experimentation at LEP. This accelerator is built at CERN, Geneva, and is due to start operation in July 1989. One of the unique features of the L3 experiment is the measurement of the momentum of the muons produced in the e + e - collisions iwht an independent muon spectrometer. This makes it possible to study final states involving muons, with high accuracy (δP/P = 2% at 45 GeV). The muon spectrometer consists of 80 large drift chambers, arranged in 16 modules or 'octants', that fill a cylindrical volume of 12 m in length, 5 m inner diameter and 12 m outer diameter. The design of the drift chambers, the construction, the alignment procedure and the test results for the complete octants are described. 51 refs.; 57 figs.; 16 tabs

  4. Determination of absolute internal conversion coefficients using the SAGE spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Sorri, J., E-mail: juha.m.t.sorri@jyu.fi [University of Jyvaskyla, Department of Physics, P.O. Box 35, FI-40014 University of Jyvaskyla (Finland); Greenlees, P.T.; Papadakis, P.; Konki, J. [University of Jyvaskyla, Department of Physics, P.O. Box 35, FI-40014 University of Jyvaskyla (Finland); Cox, D.M. [University of Jyvaskyla, Department of Physics, P.O. Box 35, FI-40014 University of Jyvaskyla (Finland); Department of Physics, University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Auranen, K.; Partanen, J.; Sandzelius, M.; Pakarinen, J.; Rahkila, P.; Uusitalo, J. [University of Jyvaskyla, Department of Physics, P.O. Box 35, FI-40014 University of Jyvaskyla (Finland); Herzberg, R.-D. [Department of Physics, University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Smallcombe, J.; Davies, P.J.; Barton, C.J.; Jenkins, D.G. [Department of Physics, University of York, Heslington, York YO10 5DD (United Kingdom)

    2016-03-11

    A non-reference based method to determine internal conversion coefficients using the SAGE spectrometer is carried out for transitions in the nuclei of {sup 154}Sm, {sup 152}Sm and {sup 166}Yb. The Normalised-Peak-to-Gamma method is in general an efficient tool to extract internal conversion coefficients. However, in many cases the required well-known reference transitions are not available. The data analysis steps required to determine absolute internal conversion coefficients with the SAGE spectrometer are presented. In addition, several background suppression methods are introduced and an example of how ancillary detectors can be used to select specific reaction products is given. The results obtained for ground-state band E2 transitions show that the absolute internal conversion coefficients can be extracted using the methods described with a reasonable accuracy. In some cases of less intense transitions only an upper limit for the internal conversion coefficient could be given.

  5. Determination of absolute internal conversion coefficients using the SAGE spectrometer

    International Nuclear Information System (INIS)

    Sorri, J.; Greenlees, P.T.; Papadakis, P.; Konki, J.; Cox, D.M.; Auranen, K.; Partanen, J.; Sandzelius, M.; Pakarinen, J.; Rahkila, P.; Uusitalo, J.; Herzberg, R.-D.; Smallcombe, J.; Davies, P.J.; Barton, C.J.; Jenkins, D.G.

    2016-01-01

    A non-reference based method to determine internal conversion coefficients using the SAGE spectrometer is carried out for transitions in the nuclei of "1"5"4Sm, "1"5"2Sm and "1"6"6Yb. The Normalised-Peak-to-Gamma method is in general an efficient tool to extract internal conversion coefficients. However, in many cases the required well-known reference transitions are not available. The data analysis steps required to determine absolute internal conversion coefficients with the SAGE spectrometer are presented. In addition, several background suppression methods are introduced and an example of how ancillary detectors can be used to select specific reaction products is given. The results obtained for ground-state band E2 transitions show that the absolute internal conversion coefficients can be extracted using the methods described with a reasonable accuracy. In some cases of less intense transitions only an upper limit for the internal conversion coefficient could be given.

  6. Interfacing an aspiration ion mobility spectrometer to a triple quadrupole mass spectrometer

    International Nuclear Information System (INIS)

    Adamov, Alexey; Viidanoja, Jyrki; Kaerpaenoja, Esko; Paakkanen, Heikki; Ketola, Raimo A.; Kostiainen, Risto; Sysoev, Alexey; Kotiaho, Tapio

    2007-01-01

    This article presents the combination of an aspiration-type ion mobility spectrometer with a mass spectrometer. The interface between the aspiration ion mobility spectrometer and the mass spectrometer was designed to allow for quick mounting of the aspiration ion mobility spectrometer onto a Sciex API-300 triple quadrupole mass spectrometer. The developed instrumentation is used for gathering fundamental information on aspiration ion mobility spectrometry. Performance of the instrument is demonstrated using 2,6-di-tert-butyl pyridine and dimethyl methylphosphonate

  7. Outcrop Gamma-ray Analysis of the Cretaceous mesaverde Group: Jicarilla Apache Indian Reservation, New Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Ridgley, Jennie; Dunbar, Robyn Wright

    2001-04-25

    This report presents the results of an outcrop gamma-ray survey of six selected measured sections included in the original report. The primary objective of this second study is to provide a baseline to correlate from the outcrop and reservoir model into Mesaverde strata in the San Juan Basin subsurface. Outcrop logs were generated using a GAD-6 gamma-ray spectrometer that simultaneously recorded total counts, potassium, uranium, and thorium data.

  8. Determining the water content in concrete by gamma scattering method

    International Nuclear Information System (INIS)

    Priyada, P.; Ramar, R.; Shivaramu

    2014-01-01

    Highlights: • Gamma scattering technique for estimation of water content in concrete is given. • The scattered intensity increases with the volumetric water content. • Attenuation correction is provided to the scattered intensities. • Volumetric water content of 137 Cs radioactive source and a high resolution HPGe detector based energy dispersive gamma ray spectrometer. Concrete samples of uniform density ≈2.4 g/cm 3 are chosen for the study and the scattered intensities found to vary with the amount of water present in the specimen. The scattered intensities are corrected for attenuation effects and the results obtained with reference to a dry sample are compared with those obtained by gravimetrical and gamma transmission methods. A good agreement is seen between gamma scattering results and those obtained by gravimetric and transmission methods within accuracy of 6% and <2% change in water content can be detected

  9. Design and characterization of an interface for acquiring gamma radiation spectra

    International Nuclear Information System (INIS)

    Marin, E.; Hernandez, M.; Soto Moran, R.L.

    1991-01-01

    An interfaces for TOSHIBA personal computer is described. The evaluation of its characteristic shows the possibility of using it as analog-digital converter in spectrometer systems for educational purposes. It is also presented a MSX-Basic program which provides a very flexible data acquisition facility during gamma spectrum analysis applications

  10. Airborne gamma-ray spectrometer and magnetometer survey: Forsyth quadrangle, Round Up quadrangle, Hardin quadrangle (Montana), Sheridan quadrangle, (Wyoming). Final report

    International Nuclear Information System (INIS)

    1981-01-01

    An airborne combined radiometric and magnetic survey was performed for the Department of Energy (DOE) over the area covered by the Forsyth, Hardin, and Sheridan, and Roundup, 1:250,000 National Topographic Map Series (NTMS), quadrangle maps. The survey was part of DOE's National Uranium Resource Evaluation (NURE) program. Data were collected by a helicopter equipped with a gamma-ray spectrometer with a large crystal volume, and with a high sensitivity proton precession magnetometer. The radiometric system was calibrated at the Walker Field Calibration Pads and the Lake Mead Dynamic Test Range. Data quality was ensured during the survey by daily test flights and equipment checks. Radiometric data were corrected for live time, aircraft and equipment background, cosmic background, atmospheric radon, Compton scatter, and altitude dependence. The corrected data were statistically evaluated, plotted, and contoured to produce anomaly maps based on the radiometric response of individual geological units. The anomalies were interpreted and an interpretation map produced. Volume I contains a description of the systems used in the survey, a discussion of the calibration of the systems, the data collection procedures, the data processing procedures, the data presentation, the interpretation rationale, and the interpretation methodology. A separate Volume II for each quadrangle contains the data displays and the interpretation results

  11. Equipment for automatic measurement of gamma activity distribution in a column

    International Nuclear Information System (INIS)

    Kalincak, M.; Machan, V.; Vilcek, S.; Balkovsky, K.

    1978-01-01

    The design of a device for stepwise scanning of gamma activity distributions along chromatographic columns is described. In connection with a single-channel gamma spectrometer and a counting ratemeter with a recorder this device permits the resolution of a number of gamma emitters on the column, the determination of the gamma nuclide content in different chemical forms in the sample by means of column separation methods - Gel Chromatography Columns Scanning Method - and the determination of gamma nuclide distribution along the columns. The device permits the scanning of columns of up to 20 mm in diameter and 700 mm in length and continual scanning over a 450 mm column length with one clamping. With minor adaptations it is possible to scan columns up to 30 mm in diameter. The length of the scanned sections is 5 or 10 mm, the scanning time setting is arbitrary and variable activity levels and radiation energies may be measured. (author)

  12. Gamma dosimetry of high doses

    International Nuclear Information System (INIS)

    Martinez C, T.; Galvan G, A.; Canizal, G.

    1991-01-01

    The gamma dosimetry of high doses is problematic in almost all the classic dosemeters either based on the thermoluminescence, electric, chemical properties, etc., because they are saturated to very high dose and they are no longer useful. This work carries out an investigation in the interval of high doses. The solid system of heptahydrate ferrous sulfate, can be used as solid dosemeter of routine for high doses of radiation. The proposed method is simple, cheap and it doesn't require sophisticated spectrophotometers or spectrometers but expensive and not common in some laboratories

  13. Method Validation for the Gamma-ray Spectrometric Determination of Natural Radioactive Nuclides in NORM Samples - Method Validation for the Gamma-ray Spectrometric Determination of Natural Radionuclides in raw materials and by-products

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Young-Yong; Lim, Jong-Myoung; Jang, Mee; Kim, Chang-Jong; Chung, Kun Ho; Kang, Mun Ja; Choi, Geun-Sik [Environmental Radioactivity Assessment Team, Korea Atomic Energy Research Institute, 111, Daedeok-daero 989, Yuseong, Daejeon, 305-353 (Korea, Republic of)

    2014-07-01

    It has established the 'Act on safety control of radioactive rays around living environment' in Korea, since 2011, to protect the public from natural occurring radioactive materials (NORM) and their by-products. The increasing concerns regarding the radioactivity of those materials therefore dictate many demands for the radioactive analysis for them. There are several methods to determine the concentration of natural radionuclides, such as {sup 235}U, {sup 238}U, {sup 226}Ra, {sup 232}Th, and so on, through a radiochemical analysis using an alpha spectrometer, mass spectrometer and liquid scintillation counter. However, gamma-ray spectroscopy still has an effect on the assessment of radioactive concentration for these nuclides and their progenies. To adapt a gamma spectrometer to the determination of natural radionuclides, the feasibility of their analysis methods should be first verified and validated with respect to accuracy and time and cost constraints. In general, one of the well-known processes in analyzing uranium with a gamma spectrometer is an indirect measurement using the secular equilibrium state with their progenies in a sample. This method, however, demands the time elapsed about 3 weeks to reach the equilibrium state between {sup 226}Ra and {sup 222}Rn and the sufficient integrity of a sample bottle to prevent the leakage of radon isotopes which is a form of noble gas. The simple and quick method is to directly measure a full energy absorption peak of 186.2 keV from {sup 226}Ra without the secular equilibrium state between {sup 226}Ra and {sup 222}Rn in the common sample bottle. However, this direct measurement also has difficulties about the interference with a full energy absorption peak of 185.7 keV from {sup 235}U. In this study, direct measurement with the interference correction technique, which uses several reference peaks for gamma-rays from {sup 235}U and {sup 234}Th, and indirect measurement, which means the identification of {sup

  14. Improving detector signal processing with pulse height analysis in Moessbauer spectrometers

    International Nuclear Information System (INIS)

    Pechousek, Jiri; Mashlan, Miroslav; Frydrych, Jiri; Jancik, Dalibor; Prochazka, Roman

    2007-01-01

    A plenty of different programming techniques and instrument solutions are used in the development of Moessbauer spectrometers. Each of them should provide a faster spectrum accumulation process, increased productivity of measurements, decreased nonlinearity of the velocity scale, etc. The well known virtual instrumentation programming method has been used to design a computer-based Moessbauer spectrometer. Hardware solution was based on two commercially-available PCI modules produced by National Instruments Co. Virtual Moessbauer spectrometer is implemented by the graphical programming language LabVIEW 7 Express. This design environment allows to emulate the multichannel analyzer on the digital oscilloscope platform. This is a novel method based on Waveform Peak Detection function which allows detailed analysis of the acquired signal. The optimal treatment of the detector signal from various detector types is achieved by mathematical processing only. As a result, the possibility of an increase of signal/noise ratio is presented.

  15. Dose Rate and Mass Attenuation Coefficients of Gamma Ray for Concretes

    CERN Document Server

    Abdel-Latif, A A; Kansouh, W A; El-Sayed, F H

    2003-01-01

    This work is concerned with the study of the leakage gamma ray dose and mass attenuation coefficients for ordinary, basalt and dolomite concretes made from local ores. Concretes under investigation were constructed from gravel, basalt and dolomite ores, and then reconstructed with the addition of 3% steel fibers by weight. Measurements were carried out using a collimated beam from sup 6 sup 0 Co gamma ray source and sodium iodide (3x3) crystal with the genie 2000 gamma spectrometer. The obtained fluxes were transformed to gamma ray doses and displayed in the form of gamma ray dose rates distribution. The displayed curves were used to estimate the linear attenuation coefficients (mu), the relaxation lengths (lambda), half value layer (t sub 1 /2) and tenth value layer (t sub 1 /10). Also, The total mass attenuation coefficients of gamma ray have been calculated to the concerned concretes using XCOM (version 3.1) program and database elements cross sections from Z=1 to 100 at energies from 10 keV to 100 MeV. In...

  16. A Search for Microsecond Gamma Ray Bursts From Primordial Black Holes

    International Nuclear Information System (INIS)

    Krennrich, Frank

    2004-01-01

    The project is called SGARFACE (Short Gamma Ray Front Air Cherenkov Experiment) and is an atmospheric Cherenkov detector to provide sensitivity to short bursts of gamma rays of extraterrestrial origin. The detector is an addition to the Whipple 10m gamma ray telescope on Mt. Hopkins in southern Arizona and uses a digital trigger module for recognizing Cherenkov light flashes from gamma ray bursts. The digital trigger modules have been designed, tested and constructed at Iowa State University and have been installed at the Whipple 10m telescope. Operation of the experiment started in March 2003 and data collecting will likely continue until spring of 2005. A final results paper addressing a search for primordial black holes is likely to be finished by summer of 2005

  17. Regional radiometric map of Syria, using gamma-ray spectrometer

    International Nuclear Information System (INIS)

    Aissa, M.; Al-Hent, R.; Nasser, R.

    2005-01-01

    The regional radiometric gamma-ray spectrometry map of Syria, scaled 1/1000000, for surficial concentration of the total radioactivity (Ur), eU, eTh and %K was completely achieved after normalizing the airborne and carbon data sets to match each other. It worthy notice that, the anomalies found to be closely related to either phosphate and/or glauconite deposits. It is worth mentioning that throughout the survey work many scattered occurrences of secondary uranium mineralization were found as spots in some formations and phosphate rocks. Where this phenomena attributes to chemical and physical disseminating instead of accumulating the radioelements. So, that leads to a weak expectation for usual surface uranium deposits where attributed to the oxidizing condition. Then this expectation remains, as an open question requires answering through planning to subsurface prospecting. (Author)

  18. Nuclear level density and gamma strength function in 64Fe

    Science.gov (United States)

    Smith, M. K.; Spyrou, A.; Ahn, T.; Dombos, A. C.; Liddick, S. N.; Montes, F.; Naqvi, F.; Richman, D.; Schatz, H.; Brown, J.; Childers, K.; Crider, B. P.; Prokop, C. J.; Deleeuw, E.; Deyoung, P. A.; Langer, C.; Lewis, R.; Meisel, Z.; Pereira, J.; Quinn, S. J.; Schmidt, K.; Larsen, A. C.; Guttormsen, M.

    2017-09-01

    The Fe-Cd mass region exhibits enhanced collectivity and an unexpected increased in gamma-decay probability at low energies. These effects could be significant for r-process nucleosynthesis, where masses, beta-decay probabilities, and neutron capture cross sections are among the most important inputs. Neutron capture is notoriously difficult to measure; so the recent development of an indirect technique to constrain neutron-captures far from stability is especially valuable. This is the beta-Oslo method, which allows the extraction of the nuclear level density and gamma-ray strength function to compute neutron-capture cross sections. This work reports on 64Fe, populated via beta-decay of 64Mn at the National Superconducting Cyclotron Laboratory and measured with the 4pi Summing NaI (SuN) total gamma-ray spectrometer.

  19. Attenuation of neutrons and gamma-rays in homogeneous and multilayered shields

    International Nuclear Information System (INIS)

    Abdo, A.E.; Megahid, R.M.

    1997-01-01

    Measurements were carried-out to compare the attenuation properties of homogeneous shields and shields of two layers and three layers for fast neutrons and total gamma-rays. These were performed by measuring the fast neutron and total gamma-ray spectra behind homogeneous shields of magnetite-limonite, ilmenite-ilmenite and magnetite-magnetite concretes. The two layers assembly consists of iron and one of the above mentioned concretes, while the three layers shield consists of water, iron and one of the previously mentioned concretes. All measurements were carried-out using a neutron-gamma spectrometer with stilbene scintillator coupled to a fast photo multi player tube. Separation between pulses of recoil protons and recoil electrons was achieved by a pulse shape discrimination technique. 3 tabs., 10 figs., 13 refs

  20. MESSENGER E/V/H GRNS 3 GAMMA RAY SPECTROMETER CALIBDATA V1.0

    Data.gov (United States)

    National Aeronautics and Space Administration — Abstract ======== This data set consists of the MESSENGER GRS calibrated observations (CDRs) and the reduced data product (RDR). The GRS experiment is a gamma ray...

  1. Data Acquisition System for Electron Energy Loss Coincident Spectrometers

    International Nuclear Information System (INIS)

    Zhang Chi; Yu Xiaoqi; Yang Tao

    2005-01-01

    A Data Acquisition System (DAQ) for electron energy loss coincident spectrometers (EELCS) has been developed. The system is composed of a Multiplex Time-Digital Converter (TDC) that measures the flying time of positive and negative ions and a one-dimension position-sensitive detector that records the energy loss of scattering electrons. The experimental data are buffered in a first-in-first-out (FIFO) memory module, then transferred from the FIFO memory to PC by the USB interface. The DAQ system can record the flying time of several ions in one collision, and allows of different data collection modes. The system has been demonstrated at the Electron Energy Loss Coincident Spectrometers at the Laboratory of Atomic and Molecular Physics, USTC. A detail description of the whole system is given and experimental results shown

  2. A LUMINOUS GAMMA-RAY BINARY IN THE LARGE MAGELLANIC CLOUD

    Energy Technology Data Exchange (ETDEWEB)

    Corbet, R. H. D. [University of Maryland, Baltimore County, and X-ray Astrophysics Laboratory, Code 662 NASA Goddard Space Flight Center, Greenbelt Rd., MD 20771 (United States); Chomiuk, L.; Strader, J. [Department of Physics and Astronomy, Michigan State University, East Lansing, MI 48824 (United States); Coe, M. J. [University of Southampton, School of Physics and Astronomy, Southampton SO17 1BJ (United Kingdom); Coley, J. B. [NASA Postdoctoral Program, and Astroparticle Physics Laboratory, Code 661 NASA Goddard Space Flight Center, Greenbelt Rd., MD 20771 (United States); Dubus, G. [Institut de Planétologie et d’Astrophysique de Grenoble, Univ. Grenoble Alpes, CNRS, F-38000 Grenoble (France); Edwards, P. G.; Stevens, J. [Commonwealth Scientific and Industrial Research Organisation Astronomy and Space Science, P.O. Box 76, Epping, New South Wales 1710 (Australia); Martin, P. [Institut de Recherche en Astrophysique et Planétologie, Université de Toulouse, CNRS, F-31028 Toulouse cedex 4 (France); McBride, V. A.; Townsend, L. J. [Department of Astronomy, University of Cape Town, Private Bag X3, Rondebosch 7701 (South Africa); Udalski, A. [Warsaw University Observatory, Al. Ujazdowskie 4, 00-478 Warszawa (Poland)

    2016-10-01

    Gamma-ray binaries consist of a neutron star or a black hole interacting with a normal star to produce gamma-ray emission that dominates the radiative output of the system. Only a handful of such systems have been previously discovered, all within our Galaxy. Here, we report the discovery of a luminous gamma-ray binary in the Large Magellanic Cloud, found with the Fermi Large Area Telescope (LAT), from a search for periodic modulation in all sources in the third Fermi LAT catalog. This is the first such system to be found outside the Milky Way. The system has an orbital period of 10.3 days, and is associated with a massive O5III star located in the supernova remnant DEM L241, previously identified as the candidate high-mass X-ray binary (HMXB) CXOU J053600.0–673507. X-ray and radio emission are also modulated on the 10.3 day period, but are in anti-phase with the gamma-ray modulation. Optical radial velocity measurements suggest that the system contains a neutron star. The source is significantly more luminous than similar sources in the Milky Way, at radio, optical, X-ray, and gamma-ray wavelengths. The detection of this extra-galactic system, but no new Galactic systems, raises the possibility that the predicted number of gamma-ray binaries in our Galaxy has been overestimated, and that HMXBs may be born containing relatively slowly rotating neutron stars.

  3. Investigation of high resolution compact gamma camera module based on a continuous scintillation crystal using a novel charge division readout method

    International Nuclear Information System (INIS)

    Dai Qiusheng; Zhao Cuilan; Qi Yujin; Zhang Hualin

    2010-01-01

    The objective of this study is to investigate a high performance and lower cost compact gamma camera module for a multi-head small animal SPECT system. A compact camera module was developed using a thin Lutetium Oxyorthosilicate (LSO) scintillation crystal slice coupled to a Hamamatsu H8500 position sensitive photomultiplier tube (PSPMT). A two-stage charge division readout board based on a novel subtractive resistive readout with a truncated center-of-gravity (TCOG) positioning method was developed for the camera. The performance of the camera was evaluated using a flood 99m Tc source with a four-quadrant bar-mask phantom. The preliminary experimental results show that the image shrinkage problem associated with the conventional resistive readout can be effectively overcome by the novel subtractive resistive readout with an appropriate fraction subtraction factor. The response output area (ROA) of the camera shown in the flood image was improved up to 34%, and an intrinsic spatial resolution better than 2 mm of detector was achieved. In conclusion, the utilization of a continuous scintillation crystal and a flat-panel PSPMT equipped with a novel subtractive resistive readout is a feasible approach for developing a high performance and lower cost compact gamma camera. (authors)

  4. Analysis of the physical simulation on Fourier transform infrared spectrometer

    Science.gov (United States)

    Yue, Peng-yuan; Wan, Yu-xi; Zhao, Zhen

    2017-10-01

    A kind of oscillating arm type Fourier Transform Infrared Spectrometer (FTS) which based on the corner cube retroreflector is presented, and its principle and properties are studied. It consists of a pair of corner cube retroreflector, beam splitter and compensator. The optical path difference(OPD) is created by oscillating reciprocating motion of the moving corner cube pair, and the OPD value is four times the physical shift value of the moving corner cube pair. Due to the basic property of corner cube retroreflector, the oscillating arm type FTS has no tilt problems. It is almost ideal for very high resolution infrared spectrometer. However, there are some factors to reduce the FTS capability. First, wavefront aberration due to the figures of these surfaces will reduce modulation of FTS system; second, corner cube retroreflector consist of three plane mirror, and orthogonal to each other. When there is a deviation from right angle, it will reduced the modulation of system; third, the apexes of corner cube retroreflector are symmetric about the surface of beam splitter, if one or both of the corner cube retroreflector is displaced laterally from its nominal position, phase of off-axis rays returning from the two arms were difference, this also contributes to loss of modulation of system. In order to solve these problems, this paper sets up a non-sequential interference model, and a small amount of oscillating arm rotation is set to realize the dynamic simulation process, the dynamic interference energy data were acquired at different times, and calculated the modulation of the FTS system. In the simulation, the influence of wedge error of beam splitter, compensator or between them were discussed; effects of oscillating arm shaft deviation from the coplanar of beam splitter was analyzed; and compensation effect of corner cube retroreflector alignment on beam splitter, oscillating arm rotary shaft alignment error is analyzed. In addition, the adjustment procedure

  5. A Control and Detecting System of Micro-Near-Infrared Spectrometer Based on a MOEMS Scanning Grating Mirror

    Directory of Open Access Journals (Sweden)

    Haitao Liu

    2018-03-01

    Full Text Available Based on the scanning grating mirror we developed, this paper presents a method of the precise control of a scanning grating mirror and of high-speed spectrum data detection. In addition, the system circuit of the scanning grating mirror control and spectrum signal detecting is designed and manufactured in this paper. The mirror control system includes a drive generator module, an amplitude detection module, a feedback control module, and a variable gain amplification (VGA module; the detecting system includes a field programmable gate array (FPGA main control module, a synchronous trigger module, an analog-digital conversion (ADC module, and a universal serial bus (USB interface module. The final results of the experiment show that the control system has successfully realized the precision control of the swing of the scanning grating mirror and that the detecting system has successfully realized the high-speed acquisition and transmission of the spectral signal and the angle signals. The spectrum has been reconstructed according to the mathematical relationship between the wavelength λ and the angle β of the mirror. The resolution of the spectrometer reaches 10 nm in the wavelength range of 800–1800 nm, the signal-to-noise ratio (SNR of the spectrometer is 4562 at full scale, the spectrum data drift is 0.9% in 24 h, and the precision of the closed loop control is 0.06%.

  6. Design and construction of an Offner spectrometer based on geometrical analysis of ring fields.

    Science.gov (United States)

    Kim, Seo Hyun; Kong, Hong Jin; Lee, Jong Ung; Lee, Jun Ho; Lee, Jai Hoon

    2014-08-01

    A method to obtain an aberration-corrected Offner spectrometer without ray obstruction is proposed. A new, more efficient spectrometer optics design is suggested in order to increase its spectral resolution. The derivation of a new ring equation to eliminate ray obstruction is based on geometrical analysis of the ring fields for various numerical apertures. The analytical design applying this equation was demonstrated using the optical design software Code V in order to manufacture a spectrometer working in wavelengths of 900-1700 nm. The simulation results show that the new concept offers an analytical initial design taking the least time of calculation. The simulated spectrometer exhibited a modulation transfer function over 80% at Nyquist frequency, root-mean-square spot diameters under 8.6 μm, and a spectral resolution of 3.2 nm. The final design and its realization of a high resolution Offner spectrometer was demonstrated based on the simulation result. The equation and analytical design procedure shown here can be applied to most Offner systems regardless of the wavelength range.

  7. Micromegas Detectors for the Muon Spectrometer Upgrade of the ATLAS Experiment

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00211509

    2016-01-01

    Large area Micromegas (MM) detectors will be employed for the Muon Spectrometer upgrade of the ATLAS experiment at the LHC. A total surface of about $150m^2$ of the forward regions of the Muon Spectrometer will be equipped with 8 layers of MM modules. Each module covers a surface area of approximately 2 to $3 m^2$ for a total active area of $1200 m^2$. Together with the small- strips Thin Gap Chambers, they will compose the two New Small Wheels, which will replace the innermost stations of the ATLAS Endcap Muon tracking system in the planned 2018/19 shutdown. This upgrade will mantain a low pt threshold for single muons and provides excellent tracking capabilities for the HL-LHC phase. The NSW project requires fully efficient MM chambers with spatial resolution down to $100 \\mu m$, at rate capability up to about $15kHz/cm^2$ and operation in a moderate (highly inhomogeneous) magnetic field up to B=0.3 T. The required tracking capability is provided by the intrinsic spatial resolution combined with a challengi...

  8. Micromegas Detectors for the Muon Spectrometer Upgrade of the ATLAS Experiment

    CERN Document Server

    Bianco, Michele; The ATLAS collaboration

    2015-01-01

    Large area Micromegas (MM) detectors will be employed for the Muon Spectrometer upgrade of the ATLAS experiment at the LHC. A total surface of about 150 m2 of the forward regions of the Muon Spectrometer will be equipped with 8 layers of MM modules. Each module covers a surface area of approximately 2 to 3 m$^{2}$ for a total active area of 1200 m$^{2}$. Together with the small-strips Thin Gap Chambers, they will compose the two New Small Wheels, which will replace the innermost stations of the ATLAS Endcap Muon tracking system in the planned 2018/19 shutdown. This upgrade will maintain a low pt threshold for single muons and provides excellent tracking capabilities for the HL- LHC phase. The NSW project requires fully efficient MM chambers with spatial resolution down to 100 $ \\mu m$, a rate capability up to about 15 kHz/cm$^{2}$ and operation in a moderate (highly inhomogeneous) magnetic field up to B=0.3 T. The required tracking capability is provided by the intrinsic spatial resolution combined with a cha...

  9. In-situ gamma spectroscopic measurement of natural waters in Bulgaria

    International Nuclear Information System (INIS)

    Manushev, B.; Mandzhukov, I.; Tsankov, L.; Boshkova, T.; Gurev, V.; Mandzhukova, B.; Kozhukharov, I.; Grozev, G.

    1983-01-01

    In-situ gamma spectrometric measurements are carried out to record differences higher than the errors of measurement in the gamma-field spectra in various basins in Bulgaria - two high mountain lakes, dam and the Black sea. A standard scintillation gamma spectrometer, consisting of a scintillation detector ND-424 type, a channel analyzer NP-424 and a 128 channel Al-128 type analyzer, has been used. The sensitivity of the procedure used is sufficient to detect the transfer of nuclides by dissolution from rocks, forming the bottom and the water-collecting region of the water basin. The advancement of the experimental techniques defines the future use of the procedure. In-situ gamma spectrometric determination may be used in cases of continuous and automated control of the radiation purity of the cooling water in atomic power plants or the water basins located close to such plants and of radioactive contamination of the sea and ocean water

  10. Monolithic spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Rajic, Slobodan (Knoxville, TN); Egert, Charles M. (Oak Ridge, TN); Kahl, William K. (Knoxville, TN); Snyder, Jr., William B. (Knoxville, TN); Evans, III, Boyd M. (Oak Ridge, TN); Marlar, Troy A. (Knoxville, TN); Cunningham, Joseph P. (Oak Ridge, TN)

    1998-01-01

    A monolithic spectrometer is disclosed for use in spectroscopy. The spectrometer is a single body of translucent material with positioned surfaces for the transmission, reflection and spectral analysis of light rays.

  11. Measurement of gamma radioactivity in steel

    International Nuclear Information System (INIS)

    Wachtendonk, H.J. von; Flock, J.; Grientschnig, D.; Kircher, T.; Kroos, J.; Mertens, S.; Mueller, J.; Puchmayr, J.; Schlothmann, B.J.; Schmitz, H.U.; Troebs, V.; Unger, H.

    1999-01-01

    The steel industry is being confronted increasingly with radioactive scrap from dismantled nuclear facilities. The clearance and release regulations that exist around the world differ very greatly and are difficult to implement. A 'radioactivity measurement' working group has therefore been set up at VDEh to clarify how radioactive measurements can be integrated into the day-to-day production routine. Operating results obtained at Thyssen Krupp Stahl AG with a gamma-ray spectrometer indicate a possibility for the simple detection of radioactive contamination. (orig.) [de

  12. A NIM (Nuclear Instrumentation Module) system conjugated with optional input for pHEMT amplifier for beta and gamma spectroscopy

    International Nuclear Information System (INIS)

    Konrad, Barbara; Lüdke, Everton

    2014-01-01

    This work presents a high speed NIM module (Nuclear Instrumentation Module) to detect radiation, gamma and muons, as part of a system for natural radiation monitoring and of extraterrestrial origin. The subsystem developed consists of a preamplifier and an integrated SCA (Single Channel Analyzer), including power supplies of ± 12 and ± 24V with derivations of +3.6 and ± 5V. The single channel analyzer board, consisting of discrete logic components, operating in window modes, normal and integral. The pulse shaping block is made up of two voltage comparators working at 120 MHz with a response time > 60 ns and a logic anticoincidence system. The preamplifier promotes a noise reduction and introduces the impedance matching between the output of anode / diode photomultiplier tubes (PMTs) and subsequent equipment, providing an input impedance of 1MΩ and output impedance of 40 to 140Ω. The shaper amplifier is non-inverting and has variable input capacitance of 1000 pF. The upper and lower thresholds of the SCA are adjustable from 0 to ± 10V, and the equipment is compatible with various types of detectors, like PMTs coupled to sodium iodide crystals. For use with liquid scintillators and photodiodes with crystals (CsI: Tl) is proposed to include a preamplifier circuit pHEMT (pseudomorphic High Electron Mobility Transistor) integrated. Yet, the system presents the possibility of applications for various purposes of gamma spectroscopy and automatic detection of events producing of beta particles

  13. Compton suppression gamma-counting: The effect of count rate

    Science.gov (United States)

    Millard, H.T.

    1984-01-01

    Past research has shown that anti-coincidence shielded Ge(Li) spectrometers enhanced the signal-to-background ratios for gamma-photopeaks, which are situated on high Compton backgrounds. Ordinarily, an anti- or non-coincidence spectrum (A) and a coincidence spectrum (C) are collected simultaneously with these systems. To be useful in neutron activation analysis (NAA), the fractions of the photopeak counts routed to the two spectra must be constant from sample to sample to variations must be corrected quantitatively. Most Compton suppression counting has been done at low count rate, but in NAA applications, count rates may be much higher. To operate over the wider dynamic range, the effect of count rate on the ratio of the photopeak counts in the two spectra (A/C) was studied. It was found that as the count rate increases, A/C decreases for gammas not coincident with other gammas from the same decay. For gammas coincident with other gammas, A/C increases to a maximum and then decreases. These results suggest that calibration curves are required to correct photopeak areas so quantitative data can be obtained at higher count rates. ?? 1984.

  14. Computer generated multi-color graphics in whole body gamma spectral analysis

    International Nuclear Information System (INIS)

    Phillips, W.G.; Curtis, S.P.; Environmental Protection Agency, Las Vegas, NV)

    1984-01-01

    A medium resolution color graphics terminal (512 x 512 pixels) was appended to a computerized gamma spectrometer for the display of whole body counting data. The color display enhances the ability of a spectroscopist to identify at a glance multicolored spectral regions of interest immediate qualitative interpretation. Spectral data from subjects containing low concentrations of gamma emitters obtained by both NaI(T1) and phoswich detectors are viewed by the method. In addition, software generates a multispectral display by which the gross, background, and net spectra are displayed in color simultaneously on a single screen

  15. TRIUMF-ISAC Gamma-Ray Escape-Suppressed Spectrometer (TIGRESS): a versatile tool for radioactive beam physics

    Science.gov (United States)

    Ball, G. C.; Andreyev, A.; Austin, R. A. E.; Bandyopadhyay, D.; Becker, J. A.; Boston, A. J.; Boston, H. C.; Chen, A.; Churchman, R.; Cifarelli, F.; Cline, D.; Cooper, R. J.; Cross, D. S.; Dashdorj, D.; Demand, G.; Dimmock, M. R.; Drake, T. E.; Finlay, P.; Gagon-Moisan, F.; Gallant, A. T.; Garrett, P. E.; Green, K. L.; Grint, A. N.; Hackman, G.; Harkness, L. J.; Hayes, A. B.; Kanungo, R.; Leach, K. G.; Lee, G.; Maharaj, R.; Martin, J.-P.; Morton, A. C.; Mythili, S.; Nelson, L.; Newman, O.; Nolan, P. J.; Padilla-Rodal, E.; Pearson, C. J.; Phillips, A. A.; Porter-Peden, M.; Ressler, J. J.; Roy, R.; Ruiz, C.; Savajols, H.; Sarazin, F.; Schumaker, M. A.; Scraggs, D. P.; Svensson, C. E.; Waddington, J. C.; Wan, J. M.; Whitbeck, A.; Williams, S. J.; Wong, J.; Wu, C. Y.

    2007-05-01

    TIGRESS is a new generation γ-ray spectrometer designed for use with radioactive beams from ISAC. This paper gives an overview of the project and presents results from the first radioactive beam experiment with TIGRESS, the Coulomb excitation of 20,21Na.

  16. A novel electrostatic ion-energy spectrometer by the use of a proposed ``self-collection'' method for secondary-electron emission from a metal collector

    Science.gov (United States)

    Hirata, M.; Nagashima, S.; Cho, T.; Kohagura, J.; Yoshida, M.; Ito, H.; Numakura, T.; Minami, R.; Kondoh, T.; Nakashima, Y.; Yatsu, K.; Miyoshi, S.

    2003-03-01

    For the purpose of end-loss-ion energy analyses in open-field plasmas, a newly developed electrostatic ion-energy spectrometer is proposed on the basis of a "self-collection" principle for secondary-electron emission from a metal collector. The ion-energy spectrometer is designed with multiple grids for analyzing incident ion energies, and a set of parallelly placed metal plates with respect to lines of ambient magnetic forces in an open-ended device. One of the most important characteristic properties of this spectrometer is the use of our proposed principle of a "self-collection" mechanism due to E×B drifts for secondary electrons emitted from the grounded metal-plate collector by the use of no further additional magnetic systems except the ambient open-ended fields B. The proof-of-principle and characterization experiments are carried out by the use of a test-ion-beam line along with an additional use of a Helmholtz coil system for the formation of open magnetic fields similar to those in the GAMMA 10 end region. The applications of the developed ion-energy spectrometer for end-loss-ion diagnostics in the GAMMA 10 plasma experiments are demonstrated under the conditions with simultaneous incidence of energetic electrons produced by electron-cyclotron heatings for end-loss-plugging potential formation, since these electrons have contributed to disturb these ion signals from conventional end-loss-ion detectors.

  17. Simulation of GRIS spectrometer response to the solar gamma-ray flare of 23 July 2002

    International Nuclear Information System (INIS)

    Trofimov, Yu A; Kotov, Yu D; Yurov, V N; Lupar, E E; Faradzhaev, R M; Glyanenko, A S

    2017-01-01

    GRIS is a prospective experiment designed to measure hard X-rays and γ-rays of solar flares in the energy range from 50 keV to 200 MeV as well as solar neutrons > 30 MeV. This study considers results of GEANT 4 simulation of GRIS detectors response to cosmic background radiation and to the solar flare SOL2002-07-23 (X4.8). It is shown that the GRIS spectrometers have enough sensitivity and energy resolution to measure redshifts of some narrow γ-rays in flare spectra, that the low energy thresholds of the detectors can be lowered considerably without a risk of counting rate saturation during high magnitude flares and that at a choice between LaBr 3 (Ce) and CeBr 3 the second one is a preferable scintillator for a hard X-ray and γ-ray spectrometer of solar flares. (paper)

  18. Objective Crystal Spectrometer (OXS) for the Spectrum-X-γ satellite

    DEFF Research Database (Denmark)

    Christensen, Finn Erland; Byrnak, B.P.; Hornstrup, Allan

    1990-01-01

    The status of the Objective Crystal Spectrometer (OXS) to be flown on the Soviet Spectrum-X-Gamma satellite together with the X-ray investigation of two of the three natural crystals (LiF(220), Ge(111) and RAP(001) which are chosen as the baseline option are presented. An important result...... on the LiF(220) and Ge(111) surfaces is presented. This design allows simultaneous spectroscopy in two energy bands each centered on cosmically interesting line emission regions. X-ray reflectivity measurements demonstrate that the crystal surface can be made sufficiently smooth for the application...

  19. Calculation of background effects on the VESUVIO eV neutron spectrometer

    International Nuclear Information System (INIS)

    Mayers, J

    2011-01-01

    The VESUVIO spectrometer at the ISIS pulsed neutron source measures the momentum distribution n(p) of atoms by 'neutron Compton scattering' (NCS). Measurements of n(p) provide a unique window into the quantum behaviour of atomic nuclei in condensed matter systems. The VESUVIO 6 Li-doped neutron detectors at forward scattering angles were replaced in February 2008 by yttrium aluminium perovskite (YAP)-doped γ-ray detectors. This paper compares the performance of the two detection systems. It is shown that the YAP detectors provide a much superior resolution and general performance, but suffer from a sample-dependent gamma background. This report details how this background can be calculated and data corrected. Calculation is compared with data for two different instrument geometries. Corrected and uncorrected data are also compared for the current instrument geometry. Some indications of how the gamma background can be reduced are also given

  20. Calculation of background effects on the VESUVIO eV neutron spectrometer

    Science.gov (United States)

    Mayers, J.

    2011-01-01

    The VESUVIO spectrometer at the ISIS pulsed neutron source measures the momentum distribution n(p) of atoms by 'neutron Compton scattering' (NCS). Measurements of n(p) provide a unique window into the quantum behaviour of atomic nuclei in condensed matter systems. The VESUVIO 6Li-doped neutron detectors at forward scattering angles were replaced in February 2008 by yttrium aluminium perovskite (YAP)-doped γ-ray detectors. This paper compares the performance of the two detection systems. It is shown that the YAP detectors provide a much superior resolution and general performance, but suffer from a sample-dependent gamma background. This report details how this background can be calculated and data corrected. Calculation is compared with data for two different instrument geometries. Corrected and uncorrected data are also compared for the current instrument geometry. Some indications of how the gamma background can be reduced are also given.