WorldWideScience

Sample records for gamma sensitivity simulation

  1. Gamma sensitivity of the Eberline PCM-1

    Blanton, J.D.

    1988-01-01

    This paper reports that normally, alarm setpoints for the Eberline PCM-1 series personnel contamination monitors are calculated based upon efficiencies measured using 100-cm 2 or larger beta or mixed beta-gamma sources. This simulates the type of contamination most frequently encountered on personnel and clothing--low-level, distributed beta-gamma emitters. In most circumstances, the PCM-1's sensitivity to the other type of contamination encountered in nuclear plant work--hot particles--would be expected to be the same as, or better than, its sensitivity to distributed contamination. However, particles that are deposited on skin or clothing can be partially shielded from the view of the PCM-1's detectors. In these situations, the PCm-1's sensitivity to gamma radiation may be more relevant than its sensitivity to betas

  2. Sensitivity of Gamma-Ray Detectors to Polarization

    Yadigaroglu, I. -A.

    1996-01-01

    Previous studies have shown that the largest gamma-ray detector to date, EGRET, does not have useful polarization sensitivity. We have explored here some improved approaches to analyzing gamma-ray pair production events, leading to important gains in sensitivity to polarization. The performance of the next generation gamma-ray instrument GLAST is investigated using a detailed Monte Carlo simulation of the complete detector.

  3. Modeling and simulation of gamma camera

    Singh, B.; Kataria, S.K.; Samuel, A.M.

    2002-08-01

    Simulation techniques play a vital role in designing of sophisticated instruments and also for the training of operating and maintenance staff. Gamma camera systems have been used for functional imaging in nuclear medicine. Functional images are derived from the external counting of the gamma emitting radioactive tracer that after introduction in to the body mimics the behavior of native biochemical compound. The position sensitive detector yield the coordinates of the gamma ray interaction with the detector and are used to estimate the point of gamma ray emission within the tracer distribution space. This advanced imaging device is thus dependent on the performance of algorithm for coordinate computing, estimation of point of emission, generation of image and display of the image data. Contemporary systems also have protocols for quality control and clinical evaluation of imaging studies. Simulation of this processing leads to understanding of the basic camera design problems. This report describes a PC based package for design and simulation of gamma camera along with the options of simulating data acquisition and quality control of imaging studies. Image display and data processing the other options implemented in SIMCAM will be described in separate reports (under preparation). Gamma camera modeling and simulation in SIMCAM has preset configuration of the design parameters for various sizes of crystal detector with the option to pack the PMT on hexagon or square lattice. Different algorithm for computation of coordinates and spatial distortion removal are allowed in addition to the simulation of energy correction circuit. The user can simulate different static, dynamic, MUGA and SPECT studies. The acquired/ simulated data is processed for quality control and clinical evaluation of the imaging studies. Results show that the program can be used to assess these performances. Also the variations in performance parameters can be assessed due to the induced

  4. Neutron detection gamma ray sensitivity criteria

    Kouzes, Richard T.; Ely, James H.; Lintereur, Azaree T.; Mace, Emily K.; Stephens, Daniel L.; Woodring, Mitchell L.

    2011-01-01

    The shortage of 3 He has triggered the search for effective alternative neutron detection technologies for national security and safeguards applications. Any new detection technology must satisfy two basic criteria: (1) it must meet a neutron detection efficiency requirement, and (2) it must be insensitive to gamma-ray interference at a prescribed level, while still meeting the neutron detection requirement. It is the purpose of this paper to define measureable gamma ray sensitivity criteria for neutron detectors. Quantitative requirements are specified for: intrinsic gamma ray detection efficiency and gamma ray absolute rejection. The gamma absolute rejection ratio for neutrons (GARRn) is defined, and it is proposed that the requirement for neutron detection be 0.9 3 He based neutron detector is provided showing that this technology can meet the stated requirements. Results from tests of some alternative technologies are also reported.

  5. The Advanced Gamma-ray Imaging System (AGIS): Simulation Studies

    Fegan, Stephen; Buckley, J. H.; Bugaev, S.; Funk, S.; Konopelko, A.; Maier, G.; Vassiliev, V. V.; Simulation Studies Working Group; AGIS Collaboration

    2008-03-01

    The Advanced Gamma-ray Imaging System (AGIS) is a concept for the next generation instrument in ground-based very high energy gamma-ray astronomy. It has the goal of achieving significant improvement in sensitivity over current experiments. We present the results of simulation studies of various possible designs for AGIS. The primary characteristics of the array performance, collecting area, angular resolution, background rejection, and sensitivity are discussed.

  6. The Advanced Gamma-ray Imaging System (AGIS): Simulation Studies

    Maier, G.; Collaboration, for the AGIS

    2009-01-01

    The Advanced Gamma-ray Imaging System (AGIS) is a next-generation ground-based gamma-ray observatory being planned in the U.S. The anticipated sensitivity of AGIS is about one order of magnitude better than the sensitivity of current observatories, allowing it to measure gammaray emmission from a large number of Galactic and extra-galactic sources. We present here results of simulation studies of various possible designs for AGIS. The primary characteristics of the array performance - collect...

  7. Gamma sensitivity of pressurized drift tubes

    Baranov, S.A.; Bojko, I.R.; Shelkov, G.A.; Ignatenko, M.A.

    1995-01-01

    Using a set of commonly used radioactive sources, the efficiency of pressurized drift tubes for gammas with energy from 5.9 keV up to 1.3 MeV has been measured. The tube was made of aluminium and filled with Ar, 15%CO 2 and 2.5%iC 4 H 10 gas mixture at 3 atm. The measured efficiency is compared with the results of the calculations in the frame of our simple model as well as with that of the Monte Carlo simulation using GEANT code. The results of our calculations are in agreement with experimental data, while GEANT simulation tends to give lower efficiency in the energy range of 200 keV γ <1300 keV. The average efficiency of the tube in the field of ATLAS gamma background is about 0.45%. 8 refs., 7 figs., 1 tab

  8. Derivative based sensitivity analysis of gamma index

    Biplab Sarkar

    2015-01-01

    boundary values for evaluating the STTP against the RP. Even though the STTP passed the simple gamma pass criteria, it was found failing at many locations when the derivatives were used as the boundary values. The proposed derivative-based method can identify a noisy curve and can prove to be a useful tool for improving the sensitivity of the gamma index.

  9. Gamma ray sensitivity of superheated liquid

    Sawamura, Teruko; Sugiyama, Noriyuki; Narita, Masakuni

    2000-01-01

    The superheated drop detector (SDD) is composed of droplets of sensitive liquid with a low-boiling point and a medium supporting the dispersed droplets throughout the medium. The SDD has been mainly used for neutron dosimetry and recently also for gamma-rays. While for neutrons the conditions for bubble formation have been discussed, there has been little work for gamma-rays. We investigated the conditions for low LET radiation, such as protons and gamma-rays, and showed octafluoropropane (C 3 F 8 , boiling point -36.7degC) as advantageous liquid. The bubble formation condition is given by the energy density imparted from the charged particle to the sensitive liquid. The energy density requirement means that the energy must be deposited over a definite region length, effective to produce the vapor nucleus that becomes the visible bubble. Recently for γ-rays, Evans and Wang proposed the model that the vaporization was triggered by the energy deposition in a 'cluster' including many events in proximity in a superheated liquid. Measurements of the γ-ray sensitivity have not been sufficiently carried out and therefore the effective length or the cluster model has not been well-established. In this study the detection sensitivity was evaluated by measuring the life time of a liquid drop exposed to γ-rays. We developed a device trapping a superheated drop, where a single drop of test liquid was trapped and decompressed by an acoustic standing wave field. When a liquid drop with volume V[cm 3 ] is exposed to a γ-ray flux φ γ [cm -2 s -1 ], the average evaporation rate λ(T, P) [s -1 ] (T: temperature, P: decompressed pressure) is expressed as λ(T, P)=K γ Vφ γ (1), K γ [cm -1 ] is the γ-ray detection sensitivity per unit volume of the sensitive liquid and unit fluence. If the average rate of spontaneous evaporation is λ 0 (T, P), then the probability distribution of the life time t, the probability that t > τ, is expressed by X(τ)=exp{-(λ+λ 0 )

  10. Gate Simulation of a Gamma Camera

    Abidi, Sana; Mlaouhi, Zohra

    2008-01-01

    Medical imaging is a very important diagnostic because it allows for an exploration of the internal human body. The nuclear imaging is an imaging technique used in the nuclear medicine. It is to determine the distribution in the body of a radiotracers by detecting the radiation it emits using a detection device. Two methods are commonly used: Single Photon Emission Computed Tomography (SPECT) and the Positrons Emission Tomography (PET). In this work we are interested on modelling of a gamma camera. This simulation is based on Monte-Carlo language and in particular Gate simulator (Geant4 Application Tomographic Emission). We have simulated a clinical gamma camera called GAEDE (GKS-1) and then we validate these simulations by experiments. The purpose of this work is to monitor the performance of these gamma camera and the optimization of the detector performance and the the improvement of the images quality. (Author)

  11. Gamma-ray spectroscopy measurements and simulations for uranium mining

    Marchais, T.; Pérot, B.; Carasco, C.; Allinei, P.-G.; Chaussonnet, P.; Ma, J.-L.; Toubon, H.

    2018-01-01

    AREVA Mines and the Nuclear Measurement Laboratory of CEA Cadarache are collaborating to improve the sensitivity and precision of uranium concentration evaluation by means of gamma measurements. This paper reports gamma-ray spectra, recorded with a high-purity coaxial germanium detector, on standard cement blocks with increasing uranium content, and the corresponding MCNP simulations. The detailed MCNP model of the detector and experimental setup has been validated by calculation vs. experiment comparisons. An optimization of the detector MCNP model is presented in this paper, as well as a comparison of different nuclear data libraries to explain missing or exceeding peaks in the simulation. Energy shifts observed between the fluorescence X-rays produced by MCNP and atomic data are also investigated. The qualified numerical model will be used in further studies to develop new gamma spectroscopy approaches aiming at reducing acquisition times, especially for ore samples with low uranium content.

  12. Sensitivity Analysis of Simulation Models

    Kleijnen, J.P.C.

    2009-01-01

    This contribution presents an overview of sensitivity analysis of simulation models, including the estimation of gradients. It covers classic designs and their corresponding (meta)models; namely, resolution-III designs including fractional-factorial two-level designs for first-order polynomial

  13. Sensitiveness of jasmine cuttings to gamma radiation

    Devaiah, K.A.; Srivastava, H.C.

    1989-01-01

    Half lethal dose (LD 50 ) gamma radiation for five genotypes of jasmine and the effect of such radiation on their rooting parameters were studied. The LD 50 was close to 2.5 krad for Jasminum grandiflorum var. Pink Pin, 0.5 krad for var. Pink Thrum, 2.5 krad for J. flexile Valh., 1 krad for J. calophyllum Wall and 2 krad for J. sambac Ait var. 'Gundumalli'. Percentage of rooting, number of roots per cutting, length and thickness of roots decreased with increase in intensity of gamma irradiation. (author) 8 refs.; 4 tabs

  14. Simulating 60 Co gamma irradiation systems

    Omi, Nelson M.; Rela, Paulo R.

    2000-01-01

    The use of Cadgamma, a software dedicated to simulate 60 Co gamma irradiation systems, can lead to an optimized process and simulating, in a few hours, many configurations setups for the irradiation elements. The software can also simulate changes in the path of the product and the influence of any steady body like the support of the product support and source shoulders. These simulations minimize the number of dose mapping tests in industrial applications and allow the study of unusual setups. Cadgamma was developed at IPEN to simulate it is multipurpose 60 Co irradiation system, under construction and planned to be operating by the second half of 2001. The software was used on project stage and will help to optimize the irradiation process for each product to be treated. (author)

  15. GROSS- GAMMA RAY OBSERVATORY ATTITUDE DYNAMICS SIMULATOR

    Garrick, J.

    1994-01-01

    The Gamma Ray Observatory (GRO) spacecraft will constitute a major advance in gamma ray astronomy by offering the first opportunity for comprehensive observations in the range of 0.1 to 30,000 megaelectronvolts (MeV). The Gamma Ray Observatory Attitude Dynamics Simulator, GROSS, is designed to simulate this mission. The GRO Dynamics Simulator consists of three separate programs: the Standalone Profile Program; the Simulator Program, which contains the Simulation Control Input/Output (SCIO) Subsystem, the Truth Model (TM) Subsystem, and the Onboard Computer (OBC) Subsystem; and the Postprocessor Program. The Standalone Profile Program models the environment of the spacecraft and generates a profile data set for use by the simulator. This data set contains items such as individual external torques; GRO spacecraft, Tracking and Data Relay Satellite (TDRS), and solar and lunar ephemerides; and star data. The Standalone Profile Program is run before a simulation. The SCIO subsystem is the executive driver for the simulator. It accepts user input, initializes parameters, controls simulation, and generates output data files and simulation status display. The TM subsystem models the spacecraft dynamics, sensors, and actuators. It accepts ephemerides, star data, and environmental torques from the Standalone Profile Program. With these and actuator commands from the OBC subsystem, the TM subsystem propagates the current state of the spacecraft and generates sensor data for use by the OBC and SCIO subsystems. The OBC subsystem uses sensor data from the TM subsystem, a Kalman filter (for attitude determination), and control laws to compute actuator commands to the TM subsystem. The OBC subsystem also provides output data to the SCIO subsystem for output to the analysts. The Postprocessor Program is run after simulation is completed. It generates printer and CRT plots and tabular reports of the simulated data at the direction of the user. GROSS is written in FORTRAN 77 and

  16. Gamma response study of radiation sensitive MOSFETs for their use as gamma radiation sensor

    Srivastava, Saurabh; Kumar, A. Vinod [Radiation Safety Systems Division, Bhabha Atomic Research Centre, Mumbai (India); Aggarwal, Bharti; Singh, Arvind; Topkar, Anita, E-mail: anita@barc.gov.in [Electronics Division, Bhabha Atomic Research Centre, Mumbai (India)

    2016-05-23

    Continuous monitoring of gamma dose is important in various fields like radiation therapy, space-related research, nuclear energy programs and high energy physics experiment facilities. The present work is focused on utilization of radiation-sensitive Metal-Oxide-Semiconductor Field Effect Transistors (MOSFETs) to monitor gamma radiation doses. Static characterization of these detectors was performed to check their expected current-voltage relationship. Threshold voltage and transconductance per unit gate to source voltage (K factor) were calculated from the experimental data. The detector was exposed to gamma radiation in both, with and without gate bias voltage conditions, and change in threshold voltage was monitored at different gamma doses. The experimental data was fitted to obtain equation for dependence of threshold voltage on gamma dose. More than ten times increase in sensitivity was observed in biased condition (+3 V) compared to the unbiased case.

  17. IMRT QA: Selecting gamma criteria based on error detection sensitivity

    Steers, Jennifer M. [Department of Radiation Oncology, Cedars-Sinai Medical Center, Los Angeles, California 90048 and Physics and Biology in Medicine IDP, David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, California 90095 (United States); Fraass, Benedick A., E-mail: benedick.fraass@cshs.org [Department of Radiation Oncology, Cedars-Sinai Medical Center, Los Angeles, California 90048 (United States)

    2016-04-15

    Purpose: The gamma comparison is widely used to evaluate the agreement between measurements and treatment planning system calculations in patient-specific intensity modulated radiation therapy (IMRT) quality assurance (QA). However, recent publications have raised concerns about the lack of sensitivity when employing commonly used gamma criteria. Understanding the actual sensitivity of a wide range of different gamma criteria may allow the definition of more meaningful gamma criteria and tolerance limits in IMRT QA. We present a method that allows the quantitative determination of gamma criteria sensitivity to induced errors which can be applied to any unique combination of device, delivery technique, and software utilized in a specific clinic. Methods: A total of 21 DMLC IMRT QA measurements (ArcCHECK®, Sun Nuclear) were compared to QA plan calculations with induced errors. Three scenarios were studied: MU errors, multi-leaf collimator (MLC) errors, and the sensitivity of the gamma comparison to changes in penumbra width. Gamma comparisons were performed between measurements and error-induced calculations using a wide range of gamma criteria, resulting in a total of over 20 000 gamma comparisons. Gamma passing rates for each error class and case were graphed against error magnitude to create error curves in order to represent the range of missed errors in routine IMRT QA using 36 different gamma criteria. Results: This study demonstrates that systematic errors and case-specific errors can be detected by the error curve analysis. Depending on the location of the error curve peak (e.g., not centered about zero), 3%/3 mm threshold = 10% at 90% pixels passing may miss errors as large as 15% MU errors and ±1 cm random MLC errors for some cases. As the dose threshold parameter was increased for a given %Diff/distance-to-agreement (DTA) setting, error sensitivity was increased by up to a factor of two for select cases. This increased sensitivity with increasing dose

  18. Differential sensitivity of Chironomus and human hemoglobin to gamma radiation

    Gaikwad, Pallavi S.; Panicker, Lata; Mohole, Madhura; Sawant, Sangeeta; Mukhopadhyaya, Rita; Nath, Bimalendu B.

    2016-01-01

    Chironomus ramosus is known to tolerate high doses of gamma radiation exposure. Larvae of this insect possess more than 95% of hemoglobin (Hb) in its circulatory hemolymph. This is a comparative study to see effect of gamma radiation on Hb of Chironomus and humans, two evolutionarily diverse organisms one having extracellular and the other intracellular Hb respectively. Stability and integrity of Chironomus and human Hb to gamma radiation was compared using biophysical techniques like Dynamic Light Scattering (DLS), UV-visible spectroscopy, fluorescence spectrometry and CD spectroscopy after exposure of whole larvae, larval hemolymph, human peripheral blood, purified Chironomus and human Hb. Sequence- and structure-based bioinformatics methods were used to analyze the sequence and structural similarities or differences in the heme pockets of respective Hbs. Resistivity of Chironomus Hb to gamma radiation is remarkably higher than human Hb. Human Hb exhibited loss of heme iron at a relatively low dose of gamma radiation exposure as compared to Chironomus Hb. Unlike human Hb, the heme pocket of Chironomus Hb is rich in aromatic amino acids. Higher hydophobicity around heme pocket confers stability of Chironomus Hb compared to human Hb. Previously reported gamma radiation tolerance of Chironomus can be largely attributed to its evolutionarily ancient form of extracellular Hb as evident from the present study. -- Highlights: •Comparison of radiation tolerant Chironomus Hb and radiation sensitive Human Hb. •Amino acid composition of midge and human heme confer differential hydrophobicity. •Heme pocket of evolutionarily ancient midge Hb provide gamma radiation resistivity.

  19. Differential sensitivity of Chironomus and human hemoglobin to gamma radiation

    Gaikwad, Pallavi S. [Stress Biology Research Laboratory, Department of Zoology, Savitribai Phule University, Pune, 411007 (India); Molecular Biology Division, Bhabha Atomic Research Centre, Trombay, Mumbai, 400085 (India); Panicker, Lata [Solid State Physics Division, Bhabha Atomic Research Centre, Trombay, Mumbai, 400085 (India); Mohole, Madhura; Sawant, Sangeeta [Bioinformatics Center, Savitribai Phule Pune University, Pune, 411007 (India); Mukhopadhyaya, Rita [Molecular Biology Division, Bhabha Atomic Research Centre, Trombay, Mumbai, 400085 (India); Nath, Bimalendu B., E-mail: bbnath@gmail.com [Stress Biology Research Laboratory, Department of Zoology, Savitribai Phule University, Pune, 411007 (India)

    2016-08-05

    Chironomus ramosus is known to tolerate high doses of gamma radiation exposure. Larvae of this insect possess more than 95% of hemoglobin (Hb) in its circulatory hemolymph. This is a comparative study to see effect of gamma radiation on Hb of Chironomus and humans, two evolutionarily diverse organisms one having extracellular and the other intracellular Hb respectively. Stability and integrity of Chironomus and human Hb to gamma radiation was compared using biophysical techniques like Dynamic Light Scattering (DLS), UV-visible spectroscopy, fluorescence spectrometry and CD spectroscopy after exposure of whole larvae, larval hemolymph, human peripheral blood, purified Chironomus and human Hb. Sequence- and structure-based bioinformatics methods were used to analyze the sequence and structural similarities or differences in the heme pockets of respective Hbs. Resistivity of Chironomus Hb to gamma radiation is remarkably higher than human Hb. Human Hb exhibited loss of heme iron at a relatively low dose of gamma radiation exposure as compared to Chironomus Hb. Unlike human Hb, the heme pocket of Chironomus Hb is rich in aromatic amino acids. Higher hydophobicity around heme pocket confers stability of Chironomus Hb compared to human Hb. Previously reported gamma radiation tolerance of Chironomus can be largely attributed to its evolutionarily ancient form of extracellular Hb as evident from the present study. -- Highlights: •Comparison of radiation tolerant Chironomus Hb and radiation sensitive Human Hb. •Amino acid composition of midge and human heme confer differential hydrophobicity. •Heme pocket of evolutionarily ancient midge Hb provide gamma radiation resistivity.

  20. Applications of Monte Carlo simulations of gamma-ray spectra

    Clark, D.D.

    1995-01-01

    A short, convenient computer program based on the Monte Carlo method that was developed to generate simulated gamma-ray spectra has been found to have useful applications in research and teaching. In research, we use it to predict spectra in neutron activation analysis (NAA), particularly in prompt gamma-ray NAA (PGNAA). In teaching, it is used to illustrate the dependence of detector response functions on the nature of gamma-ray interactions, the incident gamma-ray energy, and detector geometry

  1. On sensitivity of gamma families to the model of nuclear interaction

    Krys, A.; Tomaszewski, A.; Wrotniak, J.A.

    1980-01-01

    A variety of 5 different models of nuclear interaction has been used in a Monte Carlo simulation of nuclear and electromagnetic showers in the atmosphere. The gamma families obtained from this simulation were processed in a way, analogous to one employed in analysis of Pamir experimental results. The sensitivity of observed pattern to the nuclear interaction model assumptions was investigated. Such sensitivity, though not a strong one, was found. In case of longitudinal (or energetical) family characteristics, the changes in nuclear interaction should be really large, if they were to be reflected in the experimental data -with all methodical error possibilities. The transverse characteristics of gamma families are more sensitive to the assumed transverse momentum distribution, but they feel the longitudinal features of nuclear interaction as well. Additionally, there was tested the dependence of observed family pattern on some methodical effects (resolving power of X-ray film, radial cut-off and energy underestimation.) (author)

  2. Sensitivity of self-powered detector probes to electron and gamma-ray fields

    Lone, M A; Wong, P Y [Atomic Energy of Canada Ltd., Chalk River, ON (Canada)

    1996-12-31

    A self-powered detector (SPD) is a simple, passive device that consists of a coaxial probe with a metallic outer sleeve, a mineral oxide insulating layer, and a metallic inner core. SPD`s are used in nuclear reactors to monitor neutron and gamma fields. Responses of SPD`s to electrons and {gamma}-rays of various energies were investigated with Monte Carlo simulations. Transmission filters were studied for the design of threshold SPD probes used for online monitoring of the energy spectrum of high-power industrial electron accelerator beams. Filters were also investigated for the enhancement of {gamma}-ray sensitivity of an SPD placed in a mixed electron and {gamma}-ray field. (author). 30 refs., 1 tab., 8 figs.

  3. The effects of gamma irradiation on neutron displacement sensitivity of lateral PNP bipolar transistors

    Wang, Chenhui; Chen, Wei; Liu, Yan; Jin, Xiaoming; Yang, Shanchao; Qi, Chao

    2016-01-01

    The effects of gamma irradiation on neutron displacement sensitivity of four types of lateral PNP bipolar transistors (LPNPs) with different neutral base widths, emitter widths and the doping concentrations of the epitaxial base region are studied. The physical mechanisms of the effects are explored by defect analysis using deep level transient spectroscopy (DLTS) techniques and numerical simulations of recombination process in the base region of the lateral PNP bipolar transistors, and are verified by the experiments on gate-controlled lateral PNP bipolar transistors (GCLPNPs) manufactured in the identical commercial bipolar process with different gate bias voltage. The results indicate that gamma irradiation increases neutron displacement damage sensitivity of lateral PNP bipolar transistors and the mechanism of this phenomenon is that positive charge induced by gamma irradiation enhances the recombination process in the defects induced by neutrons in the base region, leading to larger recombination component of base current and greater gain degradation.

  4. The effects of gamma irradiation on neutron displacement sensitivity of lateral PNP bipolar transistors

    Wang, Chenhui, E-mail: wangchenhui@nint.ac.cn; Chen, Wei; Liu, Yan; Jin, Xiaoming; Yang, Shanchao; Qi, Chao

    2016-09-21

    The effects of gamma irradiation on neutron displacement sensitivity of four types of lateral PNP bipolar transistors (LPNPs) with different neutral base widths, emitter widths and the doping concentrations of the epitaxial base region are studied. The physical mechanisms of the effects are explored by defect analysis using deep level transient spectroscopy (DLTS) techniques and numerical simulations of recombination process in the base region of the lateral PNP bipolar transistors, and are verified by the experiments on gate-controlled lateral PNP bipolar transistors (GCLPNPs) manufactured in the identical commercial bipolar process with different gate bias voltage. The results indicate that gamma irradiation increases neutron displacement damage sensitivity of lateral PNP bipolar transistors and the mechanism of this phenomenon is that positive charge induced by gamma irradiation enhances the recombination process in the defects induced by neutrons in the base region, leading to larger recombination component of base current and greater gain degradation.

  5. Geant4 simulation of a 3D high resolution gamma camera

    Akhdar, H.; Kezzar, K.; Aksouh, F.; Assemi, N.; AlGhamdi, S.; AlGarawi, M.; Gerl, J.

    2015-01-01

    The aim of this work is to develop a 3D gamma camera with high position resolution and sensitivity relying on both distance/absorption and Compton scattering techniques and without using any passive collimation. The proposed gamma camera is simulated in order to predict its performance using the full benefit of Geant4 features that allow the construction of the needed geometry of the detectors, have full control of the incident gamma particles and study the response of the detector in order to test the suggested geometries. Three different geometries are simulated and each configuration is tested with three different scintillation materials (LaBr3, LYSO and CeBr3)

  6. Gamma ray polarimetry using a position sensitive germanium detector

    Kroeger, R A; Kurfess, J D; Phlips, B F

    1999-01-01

    Imaging gamma-ray detectors make sensitive polarimeters in the Compton energy regime by measuring the scatter direction of gamma rays. The principle is to capitalize on the angular dependence of the Compton scattering cross section to polarized gamma rays and measure the distribution of scatter directions within the detector. This technique is effective in a double-sided germanium detector between roughly 50 keV and 1 MeV. This paper reviews device characteristics important to the optimization of a Compton polarimeter, and summarizes measurements we have made using a device with a 5x5 cm active area, 1 cm thickness, and strip-electrodes on a 2 mm pitch.

  7. SENSITIVITY OF THE CUMIN SEEDS ASSOCIATED FUNGI TO GAMMA RADIATION

    BOTROS, H.W.; HELAL, I.M.; EL TOBGY, K.M.K.

    2008-01-01

    The present study was carried out to investigate the sensitivity of fungi associated to cumin seeds for gamma radiation. In this regard, the isolated seed associated fungi from the cumin seeds were fifteen fungal species belonging to five genera. The fungal species concerning, Aspergillus ochraceus, Fusarium oxysporium and Aspergillus flavus were the predominant fungi in percentages of 17.8, 15.83 and 12.78 %, respectively. Aspergillus ochraceus was the most effective prevalent fungi on the seed germination causing highest percentage of seed invasion followed by Fusarium oxysporium and Aspergillus flavus. The amylolytic, proteolytic and lipolytic activity and mycotoxin production of the three predominant fungi were negatively influenced by gamma radiation when exposed to doses of 1.0 , 1.5 , 2.5 , 3.5 , 5.0 and 7.5 kGy a behaviour which was parallel to the inhibition in the amount of growth by gamma irradiation

  8. Gamma irradiation increase the sensitivity of Salmonella to antibiotics

    Ben Miloud, Najla; Barkallah, Insaf

    2008-01-01

    In order to study the effect of ionizing radiation on the resistance of Salmonella to antibiotics, four strains of Salmonella were isolated from foods, The different strains used in the present study are (S. Hadar isolate 287, S. Hadar isolate 63, S. Cerro isolate 291, S. Zanzibar isolate 1103), antibiogram analyses were made to test the in vitro-sensitivity of irradiated Salmonella isolates to different antibiotics.The analyse of Control and exposed antibiograms showed that gamma radiation have increased the sensitivity of Salmonella isolates to Cefalotin, Chloramphenicol, Nalidixic acid, Spiramycin and Gentamycin excepted S. Hadar isolate 287 that was resistant to Cefalotin and became sensitive after irradiation. Statistical analyses showed that the effect of different irradiation dose treatment on the antibiotic sensitivity is increasingly significant. The irradiation didn't induce modifications of the sensitivity to other antibiotics,probably because of their nature, of their penetration mode inside the cell or their action way

  9. Sensitivity Analysis of Cf-252 (sf) Neutron and Gamma Observables in CGMF

    Carter, Austin Lewis [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Talou, Patrick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Stetcu, Ionel [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Kiedrowski, Brian Christopher [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Jaffke, Patrick John [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-12-06

    CGMF is a Monte Carlo code that simulates the decay of primary fission fragments by emission of neutrons and gamma rays, according to the Hauser-Feshbach equations. As the CGMF code was recently integrated into the MCNP6.2 transport code, great emphasis has been placed on providing optimal parameters to CGMF such that many different observables are accurately represented. Of these observables, the prompt neutron spectrum, prompt neutron multiplicity, prompt gamma spectrum, and prompt gamma multiplicity are crucial for accurate transport simulations of criticality and nonproliferation applications. This contribution to the ongoing efforts to improve CGMF presents a study of the sensitivity of various neutron and gamma observables to several input parameters for Californium-252 spontaneous fission. Among the most influential parameters are those that affect the input yield distributions in fragment mass and total kinetic energy (TKE). A new scheme for representing Y(A,TKE) was implemented in CGMF using three fission modes, S1, S2 and SL. The sensitivity profiles were calculated for 17 total parameters, which show that the neutron multiplicity distribution is strongly affected by the TKE distribution of the fragments. The total excitation energy (TXE) of the fragments is shared according to a parameter RT, which is defined as the ratio of the light to heavy initial temperatures. The sensitivity profile of the neutron multiplicity shows a second order effect of RT on the mean neutron multiplicity. A final sensitivity profile was produced for the parameter alpha, which affects the spin of the fragments. Higher values of alpha lead to higher fragment spins, which inhibit the emission of neutrons. Understanding the sensitivity of the prompt neutron and gamma observables to the many CGMF input parameters provides a platform for the optimization of these parameters.

  10. Monte Carlo simulation for dual head gamma camera

    Osman, Yousif Bashir Soliman

    2015-12-01

    Monte Carlo (MC) simulation technique was used widely in medical physics applications. In nuclear medicine MC was used to design new medical imaging devices such as positron emission tomography (PET), gamma camera and single photon emission computed tomography (SPECT). Also it can be used to study the factors affecting image quality and internal dosimetry, Gate is on of monte Carlo code that has a number of advantages for simulation of SPECT and PET. There is a limit accessibilities in machines which are used in clinics because of the work load of machines. This makes it hard to evaluate some factors effecting machine performance which must be evaluated routinely. Also because of difficulties of carrying out scientific research and training of students, MC model can be optimum solution for the problem. The aim of this study was to use gate monte Carlo code to model Nucline spirit, medico dual head gamma camera hosted in radiation and isotopes center of Khartoum which is equipped with low energy general purpose LEGP collimators. This was used model to evaluate spatial resolution and sensitivity which is important factor affecting image quality and to demonstrate the validity of gate by comparing experimental results with simulation results on spatial resolution. The gate model of Nuclide spirit, medico dual head gamma camera was developed by applying manufacturer specifications. Then simulation was run. In evaluation of spatial resolution the FWHM was calculated from image profile of line source of Tc 99m gammas emitter of energy 140 KeV at different distances from modeled camera head at 5,10,15,20,22,27,32,37 cm and for these distances the spatial resolution was founded to be 5.76, 7.73, 10.7, 13.8, 14.01,16.91, 19.75 and 21.9 mm, respectively. These results showed a decrement of spatial resolution with increase of the distance between object (line source) and collimator in linear manner. FWHM calculated at 10 cm was compared with experimental results. The

  11. UV- and gamma-radiation sensitive mutants of Arabidopsis thaliana

    Jiang, C.Z.; Yen, C.N.; Cronin, K.; Mitchell, D.; Britt, A.B.

    1997-01-01

    Arabidopsis seedlings repair UV-induced DNA damage via light-dependent and -independent pathways. The mechanism of the ''dark repair'' pathway is still unknown. To determine the number of genes required for dark repair and to investigate the substrate-specificity of this process we isolated mutants with enhanced sensitivity to UV radiation in the absence of photoreactivating light. Seven independently derived UV sensitive mutants were isolated from an EMS-mutagenized population. These fell into six complementation groups, two of which (UVR1 and UVH1) have previously been defined. Four of these mutants are defective in the dark repair of UV-induced pyrimidine [6-4] pyrimidinone dimers. These four mutant lines are sensitive to the growth-inhibitory effects of gamma radiation, suggesting that this repair pathway is also involved in the repair of some type of gamma-induced DNA damage product. The requirement for the coordinate action of several different gene products for effective repair of pyrimidine dimers, as well as the nonspecific nature of the repair activity, is consistent with nucleotide excision repair mechanisms previously described in Saccharomyces cerevisiae and nonplant higher eukaryotes and inconsistent with substrate-specific base excision repair mechanisms found in some bacteria, bacteriophage, and fungi. (author)

  12. Monte Carlo simulation of determining porosity by using dual gamma detectors

    Zhang Feng; Liu Juntao; Yu Huawei; Yuan Chao; Jia Yan

    2013-01-01

    Current formation elements spectroscopy logging technology utilize 241 Am-Be neutron source and single BGO detector to determine elements contents. It plays an important role in mineral analysis and lithology identification of unconventional oil and gas exploration, but information measured is relatively ld. Measured system based on 241 Am-Be neutron and dual detectors can be developed to realize the measurement of elements content as well as determine neutron gamma porosity by using ratio of gamma count between near and far detectors. Calculation model is built by Monte Carlo method to study neutron gamma porosity logging response with different spacing and shields. And it is concluded that measuring neutron gamma have high counts and good statistical property contrasted with measuring thermal neutron, but the sensitivity of porosity decrease. Sensitivity of porosity will increase as the spacing of dual detector increases. Spacing of far and near detectors should be around 62 cm and 35 cm respectively. Gamma counts decrease and neutron gamma porosity sensitivity increase when shield is fixed between neutron and detector. The length of main shield should be greater than 10 cm and associated shielding is about 5 cm. By Monte Carlo Simulation study, the result provides technical support for determining porosity in formation elements spectroscopy logging using 241 Am-Be neutron and gamma detectors. (authors)

  13. The Advanced Gamma-ray Imaging System (AGIS)-Simulation Studies

    Maier, G.; Buckley, J.; Bugaev, V.; Fegan, S.; Funk, S.; Konopelko, A.; Vassiliev, V. V.

    2008-12-01

    The Advanced Gamma-ray Imaging System (AGIS) is a US-led concept for a next-generation instrument in ground-based very-high-energy gamma-ray astronomy. The most important design requirement for AGIS is a sensitivity of about 10 times greater than current observatories like Veritas, H.E.S.S or MAGIC. We present results of simulation studies of various possible designs for AGIS. The primary characteristics of the array performance, collecting area, angular resolution, background rejection, and sensitivity are discussed.

  14. Sensitivity Analysis of Multidisciplinary Rotorcraft Simulations

    Wang, Li; Diskin, Boris; Biedron, Robert T.; Nielsen, Eric J.; Bauchau, Olivier A.

    2017-01-01

    A multidisciplinary sensitivity analysis of rotorcraft simulations involving tightly coupled high-fidelity computational fluid dynamics and comprehensive analysis solvers is presented and evaluated. An unstructured sensitivity-enabled Navier-Stokes solver, FUN3D, and a nonlinear flexible multibody dynamics solver, DYMORE, are coupled to predict the aerodynamic loads and structural responses of helicopter rotor blades. A discretely-consistent adjoint-based sensitivity analysis available in FUN3D provides sensitivities arising from unsteady turbulent flows and unstructured dynamic overset meshes, while a complex-variable approach is used to compute DYMORE structural sensitivities with respect to aerodynamic loads. The multidisciplinary sensitivity analysis is conducted through integrating the sensitivity components from each discipline of the coupled system. Numerical results verify accuracy of the FUN3D/DYMORE system by conducting simulations for a benchmark rotorcraft test model and comparing solutions with established analyses and experimental data. Complex-variable implementation of sensitivity analysis of DYMORE and the coupled FUN3D/DYMORE system is verified by comparing with real-valued analysis and sensitivities. Correctness of adjoint formulations for FUN3D/DYMORE interfaces is verified by comparing adjoint-based and complex-variable sensitivities. Finally, sensitivities of the lift and drag functions obtained by complex-variable FUN3D/DYMORE simulations are compared with sensitivities computed by the multidisciplinary sensitivity analysis, which couples adjoint-based flow and grid sensitivities of FUN3D and FUN3D/DYMORE interfaces with complex-variable sensitivities of DYMORE structural responses.

  15. Monte Carlo simulations of plutonium gamma-ray spectra

    Koenig, Z.M.; Carlson, J.B.; Wang, Tzu-Fang; Ruhter, W.D.

    1993-01-01

    Monte Carlo calculations were investigated as a means of simulating the gamma-ray spectra of Pu. These simulated spectra will be used to develop and evaluate gamma-ray analysis techniques for various nondestructive measurements. Simulated spectra of calculational standards can be used for code intercomparisons, to understand systematic biases and to estimate minimum detection levels of existing and proposed nondestructive analysis instruments. The capability to simulate gamma-ray spectra from HPGe detectors could significantly reduce the costs of preparing large numbers of real reference materials. MCNP was used for the Monte Carlo transport of the photons. Results from the MCNP calculations were folded in with a detector response function for a realistic spectrum. Plutonium spectrum peaks were produced with Lorentzian shapes, for the x-rays, and Gaussian distributions. The MGA code determined the Pu isotopes and specific power of this calculated spectrum and compared it to a similar analysis on a measured spectrum

  16. GQ-16, a Novel Peroxisome Proliferator-activated Receptor gamma (PPAR gamma) Ligand, Promotes Insulin Sensitization without Weight Gain

    Amato, Angelica A.; Rajagopalan, Senapathy; Lin, Jean Z.; Carvalho, Bruno M.; Figueira, Ana C. M.; Lu, Jenny; Ayers, Stephen D.; Mottin, Melina; Silveira, Rodrigo L.; Telles de Souza, Paulo; Mourao, Rosa H. V.; Saad, Mario J. A.; Togashi, Marie; Simeoni, Luiz A.; Abdalla, Dulcineia S. P.; Skaf, Munir S.; Polikparpov, Igor; Lima, Maria C. A.; Galdino, Suely L.; Brennan, Richard G.; Baxter, John D.; Pitta, Ivan R.; Webb, Paul; Phillips, Kevin J.; Neves, Francisco A. R.

    2012-01-01

    The recent discovery that peroxisome proliferator-activated receptor gamma (PPAR gamma) targeted anti-diabetic drugs function by inhibiting Cdk5-mediated phosphorylation of the receptor has provided a new viewpoint to evaluate and perhaps develop improved insulin-sensitizing agents. Herein we report

  17. A Comparison Of GADRAS Simulated And Measured Gamma Ray Spectra

    Jeffcoat, R.; Salaymeh, S.

    2010-01-01

    Gamma-ray radiation detection systems are continuously being developed and improved for detecting the presence of radioactive material and for identifying isotopes present. Gamma-ray spectra, from many different isotopes and in different types and thicknesses of attenuation material and matrixes, are needed to evaluate the performance of these devices. Recently, a test and evaluation exercise was performed by the Savannah River National Laboratory that required a large number of gamma-ray spectra. Simulated spectra were used for a major portion of the testing in order to provide a pool of data large enough for the results to be statistically significant. The test data set was comprised of two types of data, measured and simulated. The measured data were acquired with a hand-held Radioisotope Identification Device (RIID) and simulated spectra were created using Gamma Detector Response and Analysis Software (GADRAS, Mitchell and Mattingly, Sandia National Laboratory). GADRAS uses a one-dimensional discrete ordinate calculation to simulate gamma-ray spectra. The measured and simulated spectra have been analyzed and compared. This paper will discuss the results of the comparison and offer explanations for spectral differences.

  18. Study of Gamma spectra by Monte Carlo simulation

    Cantaragiu, A.; Gheorghies, A.; Borcia, C.

    2008-01-01

    The purpose of this paper is obtaining gamma ray spectra by means of a scintillation detector applying the Monte Carlo statistic simulation method using the EGS4 program. The Monte Carlo algorithm implies that the physical system is described by the probability density function which allows generating random figures and the result is taken as an average of numbers which were observed. The EGS4 program allows the simulation of the following physical processes: the photo-electrical effect, the Compton effect, the electron positron pairs generation and the Rayleigh diffusion. The gamma rays recorded by the detector are converted into electrical pulses and the gamma ray spectra are acquired and processed by means of the Nomad Plus portable spectrometer connected to a computer. As a gamma ray sources 137Cs and 60Co are used whose spectra drawn and used for study the interaction of the gamma radiations with the scintillation detector. The parameters which varied during the acquisition of the gamma ray spectra are the distance between source and detector and the measuring time. Due to the statistical processes in the detector, the peak looks like a Gauss distribution. The identification of the gamma quantum energy value is achieved by the experimental spectra peaks, thus gathering information about the position of the peak, the width and the area of the peak respectively. By means of the EGS4 program a simulation is run using these parameters and an 'ideal' spectrum is obtained, a spectrum which is not influenced by the statistical processes which take place inside the detector. Then, the convolution of the spectra is achieved by means of a normalised Gauss function. There is a close match between the experimental results and those simulated in the EGS4 program because the interactions which occurred during the simulation have a statistical behaviour close to the real one. (authors)

  19. Monte Carlo simulation of gamma ray tomography for image reconstruction

    Guedes, Karlos A.N.; Moura, Alex; Dantas, Carlos; Melo, Silvio; Lima, Emerson, E-mail: karlosguedes@hotmail.com [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil); Meric, Ilker [University of Bergen (Norway)

    2015-07-01

    The Monte Carlo simulations of known density and shape object was validate with Gamma Ray Tomography in static experiments. An aluminum half-moon piece placed inside a steel pipe was the MC simulation test object that was also measured by means of gamma ray transmission. Wall effect of the steel pipe due to irradiation geometry in a single pair source-detector tomography was evaluated by comparison with theoretical data. MCNPX code requires a defined geometry to each photon trajectory which practically prevents this usage for tomography reconstruction simulation. The solution was found by writing a program in Delphi language to create input files automation code. Simulations of tomography data by automated MNCPX code were carried out and validated by experimental data. Working in this sequence the produced data needed a databank to be stored. Experimental setup used a Cesium-137 isotopic radioactive source (7.4 × 109 Bq), and NaI(Tl) scintillation detector of (51 × 51) × 10−3 m crystal size coupled to a multichannel analyzer. A stainless steel tubes of 0,154 m internal diameter, 0.014 m thickness wall. The results show that the MCNPX simulation code adapted to automated input file is useful for generating a matrix data M(θ,t), of a computerized gamma ray tomography for any known density and regular shape object. Experimental validation used RMSE from gamma ray paths and from attenuation coefficient data. (author)

  20. Particle transport simulation for spaceborne, NaI gamma-ray spectrometers

    Dyer, C.S.; Truscott, P.R.; Sims, A.J.; Comber, C.; Hammond, N.D.A.

    1988-11-01

    Radioactivity induced in detectors by protons and secondary neutrons limits the sensitivity of spaceborne gamma-ray spectrometers. Three dimensional Monte Carlo transport codes have been employed to simulate particle transport of cosmic rays and inner-belt protons in various representations of the Gamma Ray Observatory Spacecraft and the Oriented Scintillation Spectrometer Experiment. Results are used to accurately quantify the contributions to the radioactive background, assess shielding options and examine the effect of detector and space-craft orientation in anisotropic trapped proton fluxes. (author)

  1. Monte Carlo simulations towards semi-quantitative prompt gamma activation imaging

    Kis, Zoltan; Belgya, Tamas; Szentmiklosi, Laszlo

    2011-01-01

    Numerous non-destructive techniques utilize neutron attenuation, scattering or capture to gain morphological, structural or elemental information about the material under study. However, few attempts have been made so far to use neutron-induced gamma radiation for 3D element mapping. The first ever facility using direct scanning for element imaging was set up at the Budapest Research Reactor. It was shown that the position-sensitive prompt-gamma detection (PGAI) enables us to determine the spatial distribution of major elements. Iterative Monte Carlo simulation technique has also been developed to provide not only qualitative but also semi-quantitative element distribution of a simple object.

  2. Direction-Sensitive Hand-Held Gamma-Ray Spectrometer

    Mukhopadhyay, S.

    2012-10-04

    A novel, light-weight, hand-held gamma-ray detector with directional sensitivity is being designed. The detector uses a set of multiple rings around two cylindrical surfaces, which provides precise location of two interaction points on two concentric cylindrical planes, wherefrom the source location can be traced back by back projection and/or Compton imaging technique. The detectors are 2.0 × 2.0 mm europium-doped strontium iodide (SrI2:Eu2+) crystals, whose light output has been measured to exceed 120,000 photons/MeV, making it one of the brightest scintillators in existence. The crystal’s energy resolution, less than 3% at 662 keV, is also excellent, and the response is highly linear over a wide range of gamma-ray energies. The emission of SrI2:Eu2+ is well matched to both photo-multiplier tubes and blue-enhanced silicon photodiodes. The solid-state photomultipliers used in this design (each 2.0 × 2.0 mm) are arrays of active pixel sensors (avalanche photodiodes driven beyond their breakdown voltage in reverse bias); each pixel acts as a binary photon detector, and their summed output is an analog representation of the total photon energy, while the individual pixel accurately defines the point of interaction. A simple back-projection algorithm involving cone-surface mapping is being modeled. The back projection for an event cone is a conical surface defining the possible location of the source. The cone axis is the straight line passing through the first and second interaction points.

  3. BC404 scintillators as gamma locators studied via Geant4 simulations

    Cortés, M. L.; Hoischen, R.; Eisenhauer, K.; Gerl, J.; Pietralla, N.

    2014-05-01

    In many applications in industry and academia, an accurate determination of the direction from where gamma rays are emitted is either needed or desirable. Ion-beam therapy treatments, the search for orphan sources, and homeland security applications are examples of fields that can benefit from directional sensitivity to gamma-radiation. Scintillation detectors are a good option for these types of applications as they have relatively low cost, are easy to handle and can be produced in a large range of different sizes. In this work a Geant4 simulation was developed to study the directional sensitivity of different BC404 scintillator geometries and arrangements. The simulation includes all the physical processes relevant for gamma detection in a scintillator. In particular, the creation and propagation of optical photons inside the scintillator was included. A simplified photomultiplier tube model was also simulated. The physical principle exploited is the angular dependence of the shape of the energy spectrum obtained from thin scintillator layers when irradiated from different angles. After an experimental confirmation of the working principle of the device and a check of the simulation, the possibilities and limitations of directional sensitivity to gamma radiation using scintillator layers was tested. For this purpose, point-like sources of typical energies expected in ion-beam therapy were used. Optimal scintillator thicknesses for different energies were determined and the setup efficiencies calculated. The use of arrays of scintillators to reconstruct the direction of incoming gamma rays was also studied. For this case, a spherical source emitting Bremsstrahlung radiation was used together with a setup consisting of scintillator layers. The capability of this setup to identify the center of the extended source was studied together with its angular resolution.

  4. Simulating Terrestrial Gamma-ray Flashes using SWORD (Invited)

    Gwon, C.; Grove, J.; Dwyer, J. R.; Mattson, K.; Polaski, D.; Jackson, L.

    2013-12-01

    We report on simulations of the relativistic feedback discharges involved with the production of terrestrial gamma-ray flashes (TGFs). The simulations were conducted using Geant4 using the SoftWare for the Optimization of Radiation Detectors (SWORD) framework. SWORD provides a graphical interface for setting up simulations in select high-energy radiation transport engines. Using Geant4, we determine avalanche length, the energy spectrum of the electrons and gamma-rays as they leave the field region, and the feedback factor describing the degree to which the production of energetic particles is self-sustaining. We validate our simulations against previous work in order to determine the reliability of our results. This work is funded by the Office of Naval Research.

  5. Simulating Gamma-Ray Emission in Star-forming Galaxies

    Pfrommer, Christoph [Leibniz-Institut für Astrophysik Potsdam (AIP), An der Sternwarte 16, D-14482 Potsdam (Germany); Pakmor, Rüdiger; Simpson, Christine M.; Springel, Volker, E-mail: cpfrommer@aip.de [Heidelberg Institute for Theoretical Studies, Schloss-Wolfsbrunnenweg 35, D-69118 Heidelberg (Germany)

    2017-10-01

    Star-forming galaxies emit GeV and TeV gamma-rays that are thought to originate from hadronic interactions of cosmic-ray (CR) nuclei with the interstellar medium. To understand the emission, we have used the moving-mesh code Arepo to perform magnetohydrodynamical galaxy formation simulations with self-consistent CR physics. Our galaxy models exhibit a first burst of star formation that injects CRs at supernovae. Once CRs have sufficiently accumulated in our Milky Way–like galaxy, their buoyancy force overcomes the magnetic tension of the toroidal disk field. As field lines open up, they enable anisotropically diffusing CRs to escape into the halo and to accelerate a bubble-like, CR-dominated outflow. However, these bubbles are invisible in our simulated gamma-ray maps of hadronic pion-decay and secondary inverse-Compton emission because of low gas density in the outflows. By adopting a phenomenological relation between star formation rate (SFR) and far-infrared emission and assuming that gamma-rays mainly originate from decaying pions, our simulated galaxies can reproduce the observed tight relation between far-infrared and gamma-ray emission, independent of whether we account for anisotropic CR diffusion. This demonstrates that uncertainties in modeling active CR transport processes only play a minor role in predicting gamma-ray emission from galaxies. We find that in starbursts, most of the CR energy is “calorimetrically” lost to hadronic interactions. In contrast, the gamma-ray emission deviates from this calorimetric property at low SFRs due to adiabatic losses, which cannot be identified in traditional one-zone models.

  6. Simulating Gamma-Ray Emission in Star-forming Galaxies

    Pfrommer, Christoph; Pakmor, Rüdiger; Simpson, Christine M.; Springel, Volker

    2017-10-01

    Star-forming galaxies emit GeV and TeV gamma-rays that are thought to originate from hadronic interactions of cosmic-ray (CR) nuclei with the interstellar medium. To understand the emission, we have used the moving-mesh code Arepo to perform magnetohydrodynamical galaxy formation simulations with self-consistent CR physics. Our galaxy models exhibit a first burst of star formation that injects CRs at supernovae. Once CRs have sufficiently accumulated in our Milky Way-like galaxy, their buoyancy force overcomes the magnetic tension of the toroidal disk field. As field lines open up, they enable anisotropically diffusing CRs to escape into the halo and to accelerate a bubble-like, CR-dominated outflow. However, these bubbles are invisible in our simulated gamma-ray maps of hadronic pion-decay and secondary inverse-Compton emission because of low gas density in the outflows. By adopting a phenomenological relation between star formation rate (SFR) and far-infrared emission and assuming that gamma-rays mainly originate from decaying pions, our simulated galaxies can reproduce the observed tight relation between far-infrared and gamma-ray emission, independent of whether we account for anisotropic CR diffusion. This demonstrates that uncertainties in modeling active CR transport processes only play a minor role in predicting gamma-ray emission from galaxies. We find that in starbursts, most of the CR energy is “calorimetrically” lost to hadronic interactions. In contrast, the gamma-ray emission deviates from this calorimetric property at low SFRs due to adiabatic losses, which cannot be identified in traditional one-zone models.

  7. Accelerated prompt gamma estimation for clinical proton therapy simulations

    Huisman, Brent F. B.; Létang, J. M.; Testa, É.; Sarrut, D.

    2016-11-01

    There is interest in the particle therapy community in using prompt gammas (PGs), a natural byproduct of particle treatment, for range verification and eventually dose control. However, PG production is a rare process and therefore estimation of PGs exiting a patient during a proton treatment plan executed by a Monte Carlo (MC) simulation converges slowly. Recently, different approaches to accelerating the estimation of PG yield have been presented. Sterpin et al (2015 Phys. Med. Biol. 60 4915-46) described a fast analytic method, which is still sensitive to heterogeneities. El Kanawati et al (2015 Phys. Med. Biol. 60 8067-86) described a variance reduction method (pgTLE) that accelerates the PG estimation by precomputing PG production probabilities as a function of energy and target materials, but has as a drawback that the proposed method is limited to analytical phantoms. We present a two-stage variance reduction method, named voxelized pgTLE (vpgTLE), that extends pgTLE to voxelized volumes. As a preliminary step, PG production probabilities are precomputed once and stored in a database. In stage 1, we simulate the interactions between the treatment plan and the patient CT with low statistic MC to obtain the spatial and spectral distribution of the PGs. As primary particles are propagated throughout the patient CT, the PG yields are computed in each voxel from the initial database, as a function of the current energy of the primary, the material in the voxel and the step length. The result is a voxelized image of PG yield, normalized to a single primary. The second stage uses this intermediate PG image as a source to generate and propagate the number of PGs throughout the rest of the scene geometry, e.g. into a detection device, corresponding to the number of primaries desired. We achieved a gain of around 103 for both a geometrical heterogeneous phantom and a complete patient CT treatment plan with respect to analog MC, at a convergence level of 2% relative

  8. Subset simulation for structural reliability sensitivity analysis

    Song Shufang; Lu Zhenzhou; Qiao Hongwei

    2009-01-01

    Based on two procedures for efficiently generating conditional samples, i.e. Markov chain Monte Carlo (MCMC) simulation and importance sampling (IS), two reliability sensitivity (RS) algorithms are presented. On the basis of reliability analysis of Subset simulation (Subsim), the RS of the failure probability with respect to the distribution parameter of the basic variable is transformed as a set of RS of conditional failure probabilities with respect to the distribution parameter of the basic variable. By use of the conditional samples generated by MCMC simulation and IS, procedures are established to estimate the RS of the conditional failure probabilities. The formulae of the RS estimator, its variance and its coefficient of variation are derived in detail. The results of the illustrations show high efficiency and high precision of the presented algorithms, and it is suitable for highly nonlinear limit state equation and structural system with single and multiple failure modes

  9. Effect of gamma radiation dose and sensitizer on the physical properties of irradiated natural rubber latex

    Komgrit, R.; Thawat, C.; B, Tripob; Wirach, T.

    2009-07-01

    Full text: The vulcanization of natural rubber latex can be induced by gamma radiation, which enhances cross-linking within the rubber matrix. The purpose of this research is to investigate the effect of gamma radiation dose and sensitizers on the physical properties of irradiated natural rubber. Three sensitizers n-butyl acrylate (n-B A), tetrachloroethylene (C 2 Cl 4 ) and trichloromethane (CHCl 3 ) were mixed with natural rubber latex before irradiation with gamma ray dose varied from 14 to 22 kGy. Results showed that the mixture of three sensitizers with specific ratios effectively induced the cross-linking of natural rubber latex. The cross-linking ratio and improved physical properties increased with increasing gamma dose. Therefore, the mixture ratios of n-B A, C 2 Cl 4 and CHCl 3 have shown to be a critical parameter in the vulcanization of natural rubber latex by gamma radiation

  10. Simulation of scintillating fiber gamma ray detectors for medical imaging

    Chaney, R.C.; Fenyves, E.J.; Antich, P.P.

    1990-01-01

    This paper reports on plastic scintillating fibers which have been shown to be effective for high spatial and time resolution of gamma rays. They may be expected to significantly improve the resolution of current medical imaging systems such as PET and SPECT. Monte Carlo simulation of imaging systems using these detectors, provides a means to optimize their performance in this application, as well as demonstrate their resolution and efficiency. Monte Carlo results are presented for PET and SPECT systems constructed using these detectors

  11. Effects of chemical sensitizers on gamma radiation processing of ...

    The potential of gamma radiation processing in cross-linking natural rubber latex (NRL) for production of dipped goods has been studied. NRL produced in Ghana was irradiated to 10, 20, 30, 40 and 50 kGy, respectively, in a Gamma Chamber of dose rate 0.65 kGy/h. Irradiation of the NRL was also carried out in the ...

  12. Sensitivity technologies for large scale simulation

    Collis, Samuel Scott; Bartlett, Roscoe Ainsworth; Smith, Thomas Michael; Heinkenschloss, Matthias; Wilcox, Lucas C.; Hill, Judith C.; Ghattas, Omar; Berggren, Martin Olof; Akcelik, Volkan; Ober, Curtis Curry; van Bloemen Waanders, Bart Gustaaf; Keiter, Eric Richard

    2005-01-01

    Sensitivity analysis is critically important to numerous analysis algorithms, including large scale optimization, uncertainty quantification,reduced order modeling, and error estimation. Our research focused on developing tools, algorithms and standard interfaces to facilitate the implementation of sensitivity type analysis into existing code and equally important, the work was focused on ways to increase the visibility of sensitivity analysis. We attempt to accomplish the first objective through the development of hybrid automatic differentiation tools, standard linear algebra interfaces for numerical algorithms, time domain decomposition algorithms and two level Newton methods. We attempt to accomplish the second goal by presenting the results of several case studies in which direct sensitivities and adjoint methods have been effectively applied, in addition to an investigation of h-p adaptivity using adjoint based a posteriori error estimation. A mathematical overview is provided of direct sensitivities and adjoint methods for both steady state and transient simulations. Two case studies are presented to demonstrate the utility of these methods. A direct sensitivity method is implemented to solve a source inversion problem for steady state internal flows subject to convection diffusion. Real time performance is achieved using novel decomposition into offline and online calculations. Adjoint methods are used to reconstruct initial conditions of a contamination event in an external flow. We demonstrate an adjoint based transient solution. In addition, we investigated time domain decomposition algorithms in an attempt to improve the efficiency of transient simulations. Because derivative calculations are at the root of sensitivity calculations, we have developed hybrid automatic differentiation methods and implemented this approach for shape optimization for gas dynamics using the Euler equations. The hybrid automatic differentiation method was applied to a first

  13. Gamma ray observatory dynamics simulator in Ada (GRODY)

    1990-09-01

    This experiment involved the parallel development of dynamics simulators for the Gamma Ray Observatory in both FORTRAN and Ada for the purpose of evaluating the applicability of Ada to the NASA/Goddard Space Flight Center's flight dynamics environment. The experiment successfully demonstrated that Ada is a viable, valuable technology for use in this environment. In addition to building a simulator, the Ada team evaluated training approaches, developed an Ada methodology appropriate to the flight dynamics environment, and established a baseline for evaluating future Ada projects

  14. Simulation of space protons influence on silicon semiconductor devices using gamma-neutron irradiation

    Zhukov, Y.N.; Zinchenko, V.F.; Ulimov, V.N.

    1999-01-01

    In this study the authors focus on the problems of simulating the space proton energy spectra under laboratory gamma-neutron radiation tests of semiconductor devices (SD). A correct simulation of radiation effects implies to take into account and evaluate substantial differences in the processes of formation of primary defects in SD in space environment and under laboratory testing. These differences concern: 1) displacement defects, 2) ionization defects and 3) intensity of radiation. The study shows that: - the energy dependence of nonionizing energy loss (NIEL) is quite universal to predict the degradation of SD parameters associated to displacement defects, and - MOS devices that are sensitive to ionization defects indicated the same variation of parameters under conditions of equality of ionization density generated by protons and gamma radiations. (A.C.)

  15. Gamma ray induced sensitization in CaSO4:Dy and competing trap model

    Nagpal, J.S.; Kher, R.K.; Gangadharan, P.

    1979-01-01

    Gamma ray induced sensitization in CaSO 4 :Dy has been compared (by measurement of TL glow curves) for different temperatures during irradiation (25 0 , 120 0 and 250 0 C). Enhanced sensitization at elevated temperatures seems to support the competing trap model for supralinearity and sensitization in CaSO 4 :Dy. (author)

  16. Resistive plate chamber neutron and gamma sensitivity measurement with a {sup 252}Cf source

    Abbrescia, M.; Altieri, S.; Baratti, V.; Barnaba, O.; Belli, G.; Bruno, G.; Colaleo, A.; DeVecchi, C.; Guida, R. E-mail: roberto.guida@pv.infn.it; Iaselli, G.; Imbres, E.; Loddo, F.; Maggi, M.; Marangelli, B.; Musitelli, G.; Nardo, R.; Natali, S.; Nuzzo, S.; Pugliese, G.; Ranieri, A.; Ratti, S.; Riccardi, C.; Romano, F.; Torre, P.; Vicini, A.; Vitulo, P.; Volpe, F

    2003-06-21

    A bakelite double gap Resistive Plate Chamber (RPC), operating in avalanche mode, has been exposed to the radiation emitted from a {sup 252}Cf source to measure its neutron and gamma sensitivity. One of the two gaps underwent the traditional electrodes surface coating with linseed oil. RPC signals were triggered by fission events detected using BaF{sub 2} scintillators. A Monte Carlo code, inside the GEANT 3.21 framework with MICAP interface, has been used to identify the gamma and neutron contributions to the total number of collected RPC signals. A neutron sensitivity of (0.63{+-}0.02)x10{sup -3} (average energy 2 MeV) and a gamma sensitivity of (14.0{+-}0.5)x10{sup -3} (average energy 1.5 MeV) have been measured in double gap mode. Measurements done in single gap mode have shown that both neutron and gamma sensitivity are independent of the oiling treatment.

  17. Sensitivity of self-powered detector probes to electron and gamma-ray fields

    Lone, M.A.; Wong, P.Y.

    1995-01-01

    A self-powered detector (SPD) is a simple, passive device that consists of a coaxial probe with a metallic outer sleeve, a mineral oxide insulating layer, and a metallic inner core. SPD's are used in nuclear reactors to monitor neutron and gamma fields. Responses of SPD's to electrons and γ-rays of various energies were investigated with Monte Carlo simulations. Transmission filters were studied for the design of threshold SPD probes used for online monitoring of the energy spectrum of high-power industrial electron accelerator beams. Filters were also investigated for the enhancement of γ-ray sensitivity of an SPD placed in a mixed electron and γ-ray field. (author). 30 refs., 1 tab., 8 figs

  18. Simulation on a limited angle beam gamma ray tomography

    Kim, Jong Bum; Jung, Sung Hee; Moon, Jin Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2010-10-15

    Limited angle beam tomography was introduced in the medical field more than two decades ago, where it was mainly used for cardiovascular diagnostics. Later, it was also used to trace multiphase flows. In these studies, the detection systems were fixed and a scanning electron beam was rapidly swept across an xray target using deflection coils. Thus very fast scanning was possible in these studies, but their geometry resulted in a heavy and bulky system because of a complex control system and vacuum tube. Because of its heavy hardware, limited angle beam tomography has remained as indoor equipment. If the source section is replaced by a gamma ray source, limited angle beam tomography will have a very light source device. In addition, limited angle beam tomography with a gamma ray source can be designed using an open type portable gantry because it does not need a vacuum guide for an electron beam. There is a lot of need for a portable tomographic system but so far no definitive solution has been created. The inspection of industrial on-line pipes, wood telephone poles, and cultural assets are some application areas. This study introduces limited angle beam gamma ray tomography, its simulation, and image reconstruction results. Image reconstruction was performed on the virtual experimental data from a Monte Carlo simulation. Image reconstruction algorithms that are known to be useful for limited angle data were applied and their results compared

  19. Deficiency in Monte Carlo simulations of coupled neutron-gamma-ray fields

    Maleka, Peane P.; Maucec, Marko; de Meijer, Robert J.

    2011-01-01

    The deficiency in Monte Carlo simulations of coupled neutron-gamma-ray field was investigated by benchmarking two simulation codes with experimental data. Simulations showed better correspondence with the experimental data for gamma-ray transport only. In simulations, the neutron interactions with

  20. Gamma-gamma density and lithology tools simulation based on GEANT4 advanced low energy Compton scattering (GALECS) package

    Esmaeili-sani, Vahid; Moussavi-zarandi, Ali; Boghrati, Behzad; Afarideh, Hossein

    2012-01-01

    Geophysical bore-hole data represent the physical properties of rocks, such as density and formation lithology, as a function of depth in a well. Properties of rocks are obtained from gamma ray transport logs. Transport of gamma rays, from a 137 Cs point gamma source situated in a bore-hole tool, through rock media to detectors, has been simulated using a GEANT4 radiation transport code. The advanced Compton scattering concepts were used to gain better analyses about well formation. The simulation and understanding of advanced Compton scattering highly depends on how accurately the effects of Doppler broadening and Rayleigh scattering are taken into account. A Monte Carlo package that simulates the gamma-gamma well logging tools based on GEANT4 advanced low energy Compton scattering (GALECS).

  1. Gamma-gamma density and lithology tools simulation based on GEANT4 advanced low energy Compton scattering (GALECS) package

    Esmaeili-sani, Vahid, E-mail: vaheed_esmaeely80@yahoo.com [Department of Nuclear Engineering and Physics, Amirkabir University of Technology, P.O. Box 4155-4494, Tehran (Iran, Islamic Republic of); Moussavi-zarandi, Ali; Boghrati, Behzad; Afarideh, Hossein [Department of Nuclear Engineering and Physics, Amirkabir University of Technology, P.O. Box 4155-4494, Tehran (Iran, Islamic Republic of)

    2012-02-01

    Geophysical bore-hole data represent the physical properties of rocks, such as density and formation lithology, as a function of depth in a well. Properties of rocks are obtained from gamma ray transport logs. Transport of gamma rays, from a {sup 137}Cs point gamma source situated in a bore-hole tool, through rock media to detectors, has been simulated using a GEANT4 radiation transport code. The advanced Compton scattering concepts were used to gain better analyses about well formation. The simulation and understanding of advanced Compton scattering highly depends on how accurately the effects of Doppler broadening and Rayleigh scattering are taken into account. A Monte Carlo package that simulates the gamma-gamma well logging tools based on GEANT4 advanced low energy Compton scattering (GALECS).

  2. Interferon-gamma sensitizes colonic epithelial cell lines to physiological and therapeutic inducers of colonocyte apoptosis.

    O'Connell, J

    2012-02-03

    Homeostasis in the colonic epithelium is achieved by a continuous cycle of proliferation and apoptosis, in which imbalances are associated with disease. Inflammatory bowel disease (IBD) and colon cancer are associated with either excessive or insufficient apoptosis of colonic epithelial cells, respectively. By using two colonic epithelial cell lines, HT29 and SW620, we investigated how the epithelial cell\\'s sensitivity to apoptosis was regulated by the proinflammatory cytokine interferon-gamma (IFN-gamma). We found that IFN-gamma sensitized HT29 cells, and to a lesser extent SW620, to diverse inducers of apoptosis of physiologic or therapeutic relevance to the colon. These apoptosis inducers included Fas (CD95\\/APO-1) ligand (FasL), short-chain fatty acids, and chemotherapeutic drugs. The extent of IFN-gamma-mediated apoptosis sensitization in these two cell lines correlated well with the degree of IFN-gamma-mediated upregulation of the proapoptotic protease caspase-1. Although IFN-gamma alone effectively sensitized HT29 cells to apoptosis, inclusion of the protein synthesis inhibitor cyclohexamide (CHX) during apoptotic challenge was necessary for maximal sensitization of SW620. The requirement of CHX to sensitize SW620 cells to apoptosis implies a need to inhibit translation of antiapoptotic proteins absent from HT29. In particular, the antiapoptotic protein Bcl-2 was strongly expressed in SW620 cells but absent from HT29. Our results indicate that IFN-gamma increases the sensitivity of colonic epithelial cells to diverse apoptotic stimuli in concert, via upregulation of caspase-1. Our findings implicate caspase-1 and Bcl-2 as important central points of control determining the general sensitivity of colonic epithelial cells to apoptosis.

  3. Thermoluminescence of Simulated Interstellar Matter after Gamma-ray Irradiation

    Koike, K.; Nakagawa, M.; Koike, C.; Okada, M.; Chihara, H.

    2002-01-01

    Interstellar matter is known to be strongly irradiated by radiation and several types of cosmic ray particles. Simulated interstellar matter, such as forsterite $\\rm Mg_{2}SiO_{4}$, enstatite $\\rm MgSiO_{3}$ and magnesite $\\rm MgCO_{3}$ has been irradiated with the $\\rm ^{60}Co$ gamma-rays in liquid nitrogen, and also irradiated with fast neutrons at 10 K and 70 K by making use of the low-temperature irradiation facility of Kyoto University Reactor (KUR-LTL. Maximum fast neutron dose is $10^{...

  4. GRODY - GAMMA RAY OBSERVATORY DYNAMICS SIMULATOR IN ADA

    Stark, M.

    1994-01-01

    Analysts use a dynamics simulator to test the attitude control system algorithms used by a satellite. The simulator must simulate the hardware, dynamics, and environment of the particular spacecraft and provide user services which enable the analyst to conduct experiments. Researchers at Goddard's Flight Dynamics Division developed GRODY alongside GROSS (GSC-13147), a FORTRAN simulator which performs the same functions, in a case study to assess the feasibility and effectiveness of the Ada programming language for flight dynamics software development. They used popular object-oriented design techniques to link the simulator's design with its function. GRODY is designed for analysts familiar with spacecraft attitude analysis. The program supports maneuver planning as well as analytical testing and evaluation of the attitude determination and control system used on board the Gamma Ray Observatory (GRO) satellite. GRODY simulates the GRO on-board computer and Control Processor Electronics. The analyst/user sets up and controls the simulation. GRODY allows the analyst to check and update parameter values and ground commands, obtain simulation status displays, interrupt the simulation, analyze previous runs, and obtain printed output of simulation runs. The video terminal screen display allows visibility of command sequences, full-screen display and modification of parameters using input fields, and verification of all input data. Data input available for modification includes alignment and performance parameters for all attitude hardware, simulation control parameters which determine simulation scheduling and simulator output, initial conditions, and on-board computer commands. GRODY generates eight types of output: simulation results data set, analysis report, parameter report, simulation report, status display, plots, diagnostic output (which helps the user trace any problems that have occurred during a simulation), and a permanent log of all runs and errors. The

  5. Development of a high sensitivity pinhole type gamma camera using semiconductors for low dose rate fields

    Ueno, Yuichiro; Takahashi, Isao; Ishitsu, Takafumi; Tadokoro, Takahiro; Okada, Koichi; Nagumo, Yasushi; Fujishima, Yasutake; Yoshida, Akira; Umegaki, Kikuo

    2018-06-01

    We developed a pinhole type gamma camera, using a compact detector module of a pixelated CdTe semiconductor, which has suitable sensitivity and quantitative accuracy for low dose rate fields. In order to improve the sensitivity of the pinhole type semiconductor gamma camera, we adopted three methods: a signal processing method to set the discriminating level lower, a high sensitivity pinhole collimator and a smoothing image filter that improves the efficiency of the source identification. We tested basic performances of the developed gamma camera and carefully examined effects of the three methods. From the sensitivity test, we found that the effective sensitivity was about 21 times higher than that of the gamma camera for high dose rate fields which we had previously developed. We confirmed that the gamma camera had sufficient sensitivity and high quantitative accuracy; for example, a weak hot spot (0.9 μSv/h) around a tree root could be detected within 45 min in a low dose rate field test, and errors of measured dose rates with point sources were less than 7% in a dose rate accuracy test.

  6. Neutron and gamma sensitivities of self-powered detectors: Monte Carlo modelling

    Vermeeren, Ludo [SCK-CEN, Nuclear Research Centre, Boeretang 200, B-2400 Mol, (Belgium)

    2015-07-01

    This paper deals with the development of a detailed Monte Carlo approach for the calculation of the absolute neutron sensitivity of SPNDs, which makes use of the MCNP code. We will explain the calculation approach, including the activation and beta emission steps, the gamma-electron interactions, the charge deposition in the various detector parts and the effect of the space charge field in the insulator. The model can also be applied for the calculation of the gamma sensitivity of self-powered detectors and for the radiation-induced currents in signal cables. The model yields detailed information on the various contributions to the sensor currents, with distinct response times. Results for the neutron sensitivity of various types of SPNDs are in excellent agreement with experimental data obtained at the BR2 research reactor. For typical neutron to gamma flux ratios, the calculated gamma induced SPND currents are significantly lower than the neutron induced currents. The gamma sensitivity depends very strongly upon the immediate detector surroundings and on the gamma spectrum. Our calculation method opens the way to a reliable on-line determination of the absolute in-pile thermal neutron flux. (authors)

  7. Effect of gamma irradiation on the sensitivities of escherichia coli at deep frozen conditions

    Takigami, Machiko; Ito, Hitoshi

    1996-01-01

    Phosphate buffer suspensions of three strains of Escherichia coli were irradiated with gamma-rays at room temperature and deep frozen conditions. They were inoculated on MacConkey agar plates to see the comparative sensitivities to the irradiation. Compared to the irradiation at room temperature, the sensitivities of the strains decreased by irradiation at deep frozen conditions. Addition of glycerol to the E. coli suspensions decreased the sensitivities of E. coli to gamma-rays not only at room temperature but also at deep frozen conditions. These phenomena were elucidated by the decrease of production and mobility of OH radicals at deep frozen conditions. (author)

  8. PID controller simulator software for DC motor of gamma scanning

    Arjoni Amir

    2008-01-01

    Mostly PID controller (Proportional-Integral-Derivative) has been used in industry. For certain applications, it can be used as a Proportional (P) model only, or as a Proportional-Integral (PI) model. The aim of this paper is to design a PID controller simulator software for DC motor which is used in gamma scanning system. A DC motor is described as a plant of SISO (Single Input Single Output) which is used for pulling down the load (detector + casing) and gamma radiation source (Co-60 + container) by using sling cable. A DC motor consist of an armature and a rotor, the equivalent circuit of DC motor is shown in a transfer function equation between output parameter (angular speed DC motor) and input parameter (voltage of DC motor). Methods used for the process of PID controller design is to arrange the PID controller parameter (Kc, Ti, Td) so that there are more PID controller transfer function model which are able to control angular speed of DC motor in stable condition, as design criteria requirement is needed. Design criteria requirement for control system are the settling time < 3 second, overshoot < 5%, rise time = 0.25 second, steady state gain = 1 and peak time < 3 second with step response reference 1 rad/second. The result of simulation gives several models of PID controller in function transfer equation which is similar with design criteria requirement in a equation of function transfer of order 2 for numerator and order 1 for denominator. (author)

  9. Development of a dose simulation software for gamma irradiation systems

    Omi, Nelson Minoru

    2000-01-01

    The use of high temperature, thermal and chemical treatment are among the used sterilization process of food and many products. The ionizing radiation came as another option, it has being used for many purposes and it became available due to the technological development in the second half of the 20 th century. Together with sterilization, many uses of the ionizing radiation were developed, such as applications on health, industrial products and waste recycling, food irradiation, vulcanizing, polymerization and gems color enhancing. The 60 Co gamma stands out among the used radiation sources on commercial facilities. lt is used to optimize this process with many dose mapping tests. The objective of this work is to develop a software to simulate the doses in 60 Co gamma irradiation systems. lt can be used to optimize a process on the project stage of a facility and to make viability studies for new applications in installations already set up. The validation of this software was done comparing the simulation results with the dosimetry data of an operating irradiation plant. The flexibility of the software was verified with extra dosimetry tests performed in another sterilization facility. (author)

  10. Study, simulation and modelling of a gamma photon detector placed on an integral-type eccentric orbit; Etude, simulation et modelisation d'un detecteur de photons gamma place sur une orbite excentrique de type integral

    Diallo, N

    1999-07-01

    Gamma-ray lines are the signature of nuclear reactions and other high-energy processes that take place in the Universe. Their measurement and study provide invaluable information on many important problems in high energy astrophysics, including particle acceleration, physics of compact objects and nucleosynthesis. However the observation of astronomical gamma-ray sources has to be performed above the atmosphere because the Earth's atmosphere is opaque to gamma-rays. Unfortunately at these altitudes, spatial high energy electromagnetic radiation (X and gamma rays) detectors are exposed to intense parasite fluxes of radiation and particles induced by primary galactic cosmic rays. These fluxes as well radiation and secondary particles they generate, constitute a considerable source of background which limits their performances. Our study has been done in the framework of the INTEGRAL mission, a gamma-ray astronomy mission of the European Space Agency. INTEGRAL is devoted to the observation of celestial gamma-ray sources. It consists of two main instruments: an imager IBIS and a high resolution germanium spectrometer SPI ({delta}E/E = 1.6 10{sup -3} at 1.3 MeV). We studied the hadronic component of the SPI background. This component is due to the radioactive decay of unstable nuclides produced by the interactions of cosmic-ray protons with the materials of SPI. It consists of a continuum with gamma ray lines superimposed. To study nuclear processes, Monte Carlo simulations have been performed with the nuclear code TIERCE developed at CEA/DAM. We used the GEANT Monte Carlo code developed at CERN to simulate the germanium detectors response. Background reduction techniques as PSD (Pulse Shape Discrimination) and energetic signatures have been applied in well chosen energy ranges to reduce the background. and improve the SPI sensitivity. With the estimated SPI narrow-line sensitivity level, SPI would be able to detect many gamma ray limes emitted in the active

  11. Comparative sensitivity of tribolium SPP to gamma irradiation throughout ontogeny

    Hasan, M.M.

    1995-01-01

    Storage losses from insect attack are often as great as those sustained by the growing crops. Moreover, losses in growing crops are frequently obvious, whereas losses in stored grain are likely to be insidious. Estimates of losses to the world's supply of stored grain from insect damage range from 5 to 10 percent of the world's production (Burkholder, 1990). In certain tropical and subtropical countries as well as Bangladesh, estimates are much higher (FAO, 1977). These problems encouraged the search for other means of control, including the use of physical measures. In this respect, two methods that show promise for controlling insects without leaving harmful chemical residues are the use of gamma radiation or microwave radiation (Cornwell, 1966; Hamid et al., 1968). Of the two, irradiation of insects has attracted wide attention in various fields from development to genetics, and through its possible application to insect pest eradication programmes (Knipling, 1955). However, the control of insects in foodstuffs by irradiation depends on acquiring the necessary basic radiobiological knowledge, on advances in irradiation, and on health and safety considerations. This research is into the possible use of gamma irradiation in controlling stored product pests as an alternative to other control methods. (author)

  12. Simulated and measured neutron/gamma light output distribution for poly-energetic neutron/gamma sources

    Hosseini, S. A.; Zangian, M.; Aghabozorgi, S.

    2018-03-01

    In the present paper, the light output distribution due to poly-energetic neutron/gamma (neutron or gamma) source was calculated using the developed MCNPX-ESUT-PE (MCNPX-Energy engineering of Sharif University of Technology-Poly Energetic version) computational code. The simulation of light output distribution includes the modeling of the particle transport, the calculation of scintillation photons induced by charged particles, simulation of the scintillation photon transport and considering the light resolution obtained from the experiment. The developed computational code is able to simulate the light output distribution due to any neutron/gamma source. In the experimental step of the present study, the neutron-gamma discrimination based on the light output distribution was performed using the zero crossing method. As a case study, 241Am-9Be source was considered and the simulated and measured neutron/gamma light output distributions were compared. There is an acceptable agreement between the discriminated neutron/gamma light output distributions obtained from the simulation and experiment.

  13. Study, simulation and modelling of a gamma photon detector placed on an integral-type eccentric orbit

    Diallo, N.

    1999-01-01

    Gamma-ray lines are the signature of nuclear reactions and other high-energy processes that take place in the Universe. Their measurement and study provide invaluable information on many important problems in high energy astrophysics, including particle acceleration, physics of compact objects and nucleosynthesis. However the observation of astronomical gamma-ray sources has to be performed above the atmosphere because the Earth's atmosphere is opaque to gamma-rays. Unfortunately at these altitudes, spatial high energy electromagnetic radiation (X and gamma rays) detectors are exposed to intense parasite fluxes of radiation and particles induced by primary galactic cosmic rays. These fluxes as well radiation and secondary particles they generate, constitute a considerable source of background which limits their performances. Our study has been done in the framework of the INTEGRAL mission, a gamma-ray astronomy mission of the European Space Agency. INTEGRAL is devoted to the observation of celestial gamma-ray sources. It consists of two main instruments: an imager IBIS and a high resolution germanium spectrometer SPI (ΔE/E = 1.6 10 -3 at 1.3 MeV). We studied the hadronic component of the SPI background. This component is due to the radioactive decay of unstable nuclides produced by the interactions of cosmic-ray protons with the materials of SPI. It consists of a continuum with gamma ray lines superimposed. To study nuclear processes, Monte Carlo simulations have been performed with the nuclear code TIERCE developed at CEA/DAM. We used the GEANT Monte Carlo code developed at CERN to simulate the germanium detectors response. Background reduction techniques as PSD (Pulse Shape Discrimination) and energetic signatures have been applied in well chosen energy ranges to reduce the background. and improve the SPI sensitivity. With the estimated SPI narrow-line sensitivity level, SPI would be able to detect many gamma ray limes emitted in the active galactic sites

  14. Effect of high gamma background on neutron sensitivity of fission detectors

    Balagi, V.; Prasad, K.R.; Kataria, S.K.

    2004-01-01

    Tests were performed on two parallel plate and two cylindrical fission detectors in pulse and dc mode. The effect of gamma background on neutron sensitivity was studied in thermal neutron flux from 30 nv to 60 nv over which gamma field intensity ranging from 230 kR/h to 3.7 MR/h was superposed. In the case of one of the parallel plate detectors the fall in neutron sensitivity was observed to be 3.7% at 1 MR/h and negligible below 1 MR/h. In the case of one of the cylindrical counters the fall in neutron sensitivity was negligible below 500 kR/h and 37% at 1 MR/h. The data was used to derive the design parameters for a wide range fission detector to be procured for PFBR instrumentation for operation at 600 degC and gamma background of 1 MR/h. (author)

  15. Use of gamma-rays sensitivity for discrimination of upland cultivars of groups Indican and Japonica

    Rodrigues, Luis Roberto Franco

    2003-01-01

    Sixty-five upland rice cultivars (Oryza sativa L.) were evaluated in relation to gamma-ray sensitivity. Seeds were subjected to seven doses of gamma-radiation and sown in wooden boxes in randomised complete block design with three replications. The experiment was conducted in greenhouse during the year of 1992. Physiological effects caused by radiation in the M 1 generation, were evaluated. The results showed that the sensitivity to the radiation at doses 300 and 360 Gy was useful for distinguishing Indican and Japonica groups. (author)

  16. MCNPX simulations of the research gamma irradiator at CTEx

    Rusin, Tiago; Rebello, Wilson F.; Vellozo, Sergio O.; Gomes, Renato G.; Silva, Ademir X.

    2011-01-01

    An accurate knowledge of the dose rate distribution inside an irradiating facility is needed in order to ensure safety and guarantee efficient treatment of materials by exposure to ionizing radiation, since insufficient doses may not produce the desired effects whereas exceeding ones can compromise the properties of the irradiated items. Described in this work, are Monte Carlo simulations of the cavity-type research irradiating facility at Centro Tecnologico do Exercito performed by using the MCNPX radiation transport code. The calculations were intended to provide a better understanding of the measured dose rate distributions produced by a 42-kCi cesium- 137 source, also modeling unmapped regions of interest, either inside or outside the irradiation chambers, such as in experimental channels, or next to the moveable door and across unmapped regions of the chambers, in order to investigate scattering and attenuation of the fluxes and softening of the gamma spectrum and to predict dose rates in case of an accidental opening of the shielded door with the source out of its shielded cask. Results from calculations have been compared to measurements performed with chemical dosimeters. Comparative analyses have consistently shown a very good agreement between calculated and measured relative dose rate distributions and provided an improved knowledge on the gamma ray environment produced by the irradiator. (author)

  17. MCNPX simulations of the research gamma irradiator at CTEx

    Rusin, Tiago; Rebello, Wilson F.; Vellozo, Sergio O.; Gomes, Renato G., E-mail: tiagorusin@ime.eb.b, E-mail: rebello@ime.eb.b, E-mail: vellozo@cbpf.b, E-mail: renatoguedes@ime.eb.b [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil). Dept. de Engenharia Nuclear; Vital, Helio C., E-mail: vital@ctex.eb.b [Centro Tecnologico do Exercito (CTEx), Rio de Janeiro, RJ (Brazil); Silva, Ademir X., E-mail: ademir@con.ufrj.b [Universidade Federal do Rio de Janeiro (PEN/COPPE/UFRJ), RJ (Brazil). Coordenacao dos Programas de Pos-Graduacao de Engenharia. Programa de Engenharia Nuclear

    2011-07-01

    An accurate knowledge of the dose rate distribution inside an irradiating facility is needed in order to ensure safety and guarantee efficient treatment of materials by exposure to ionizing radiation, since insufficient doses may not produce the desired effects whereas exceeding ones can compromise the properties of the irradiated items. Described in this work, are Monte Carlo simulations of the cavity-type research irradiating facility at Centro Tecnologico do Exercito performed by using the MCNPX radiation transport code. The calculations were intended to provide a better understanding of the measured dose rate distributions produced by a 42-kCi cesium- 137 source, also modeling unmapped regions of interest, either inside or outside the irradiation chambers, such as in experimental channels, or next to the moveable door and across unmapped regions of the chambers, in order to investigate scattering and attenuation of the fluxes and softening of the gamma spectrum and to predict dose rates in case of an accidental opening of the shielded door with the source out of its shielded cask. Results from calculations have been compared to measurements performed with chemical dosimeters. Comparative analyses have consistently shown a very good agreement between calculated and measured relative dose rate distributions and provided an improved knowledge on the gamma ray environment produced by the irradiator. (author)

  18. Systems for increasing the sensitivity of gamma-ray imagers

    Mihailescu, Lucian; Vetter, Kai M.; Chivers, Daniel H.

    2012-12-11

    Systems that increase the position resolution and granularity of double sided segmented semiconductor detectors are provided. These systems increase the imaging resolution capability of such detectors, either used as Compton cameras, or as position sensitive radiation detectors in imagers such as SPECT, PET, coded apertures, multi-pinhole imagers, or other spatial or temporal modulated imagers.

  19. Isolation of cell cycle-dependent gamma ray-sensitive Chinese hamster ovary cell

    Stamato, T.D.; Weinstein, R.; Giaccia, A.; Mackenzie, L.

    1983-01-01

    A technique for the isolation of gamma ray-sensitive Chinese hamster ovary (CHO) cell mutants is described, which uses nylon cloth replica plating and photography with dark-field illumination to directly monitor colonies for growth after gamma irradiation. Two gamma ray-sensitive mutants were isolated using this method. One of these cells (XR-1) had a two-slope survival curve: an initial steep slope and then a flattening of the curve at about 10% survival. Subsequently, it was found that this cell is sensitive to gamma irradiation in G1, early S, and late G2 phases of the cell cycle, whereas in the resistant phase (late S phase) its survival approaches that of the parental cells. The D37 in the sensitive G1 period is approximately 30 rads, compared with 300 rads of the parental cell. This mutant cell is also sensitive to killing by the DNA breaking agent, bleomycin, but is relatively insensitive to UV light and ethyl methane sulfonate, suggesting that the defect is specific for agents that produce DNA strand breakage

  20. Simulation approach to coincidence summing in {gamma}-ray spectrometry

    Dziri, S., E-mail: samir.dziri@iphc.cnrs.fr [Groupe RaMsEs, Institut Pluridisciplinaire Hubert Curien (IPHC), University of Strasbourg, CNRS, IN2P3, UMR 7178, 23 rue de Loess, BP 28, 67037 Strasbourg Cedex 2 (France); Nourreddine, A.; Sellam, A.; Pape, A.; Baussan, E. [Groupe RaMsEs, Institut Pluridisciplinaire Hubert Curien (IPHC), University of Strasbourg, CNRS, IN2P3, UMR 7178, 23 rue de Loess, BP 28, 67037 Strasbourg Cedex 2 (France)

    2012-07-15

    Some of the radionuclides used for efficiency calibration of a HPGe spectrometer are subject to coincidence-summing (CS) and account must be taken of the phenomenon to obtain quantitative results when counting samples to determine their activity. We have used MCNPX simulations, which do not take CS into account, to obtain {gamma}-ray peak intensities that were compared to those observed experimentally. The loss or gain of a measured peak intensity relative to the simulated peak is attributed to CS. CS correction factors are compared with those of ETNA and GESPECOR. Application to a test sample prepared with known radionuclides gave values close to the published activities. - Highlights: Black-Right-Pointing-Pointer Coincidence summing occurs when the solid angle is increased. Black-Right-Pointing-Pointer The loss of counts gives rise to an approximative efficiency curves, this means a wrong quantitative data. Black-Right-Pointing-Pointer To overcome this problem we need mono-energetic source, otherwise, the MCNPX simulation allows by comparison with the experiment data to get the coincidence summing correction factors. Black-Right-Pointing-Pointer By multiplying these factors by the approximative efficiency, we obtain the accurate efficiency.

  1. The Effect of Gamma Irradiation on Salmonella Chester and Its Sensitivity to Antibiotics

    Basry, T. Hasan

    2000-01-01

    The sensitivity changes of Salmonella chester (S. chester) to antibiotics as the results of gamma irradiation has not much been studied. To understand the sensitivity changes of S. chester to several antibiotics as the results of gamma irradiation with the doses of 1.0; 2.5; and 5.0 kGy, an investigation was carried out using re subculture method. The irradiation effects was evaluated by using Complete. Randomized Design with factorial pattern and the data processing by Analyses of Variance and Duincan test. It revealed that after irradiation with doses of 1.0; and 2.5 kGy, S. chester more sensitive to antibiotics Amphycillin, Tetracyclin and Chloramphenicol. It was also found that using different media culture during irradiation, the sensitivity of S. chester to antibiotics was also different

  2. Calibration and simulation of a gamma array for DRAGON at ISAC

    Gigliotti, D G; Hussein, A H

    2003-01-01

    A gamma ray detector has been built for the DRAGON facility at TRIUMF to detect the gamma ray emitted in astrophysically important proton and alpha radiative capture reactions. The gamma detector was designed to balance cost with maximum solid angle coverage and efficiency. To study the properties of the current design, GEANT simulations are being carried out and compared with prototype measurements using calibration sources and radioactive beams supplied by ISAC. Simulations will be compared with data allowing a realistic simulation to be produced. This modified simulation will then be used to provide efficiency predictions of the gamma array when an actual experiment's parameters are inputted. Using the simulated efficiency of the array, cross sections for radiative capture can be calculated from the measured gamma ray yields, for the individual reactions. The following will outline some initial results of background suppression of beam related experiments. Also shown, are some preliminary comparison of poi...

  3. Sensitivity of Pseudomonas fluorescens to gamma irradiation following surface inoculations on romaine lettuce and baby spinach

    Irradiation of fresh fruits and vegetables is a post-harvest intervention measure often used to inactivate pathogenic food-borne microbes. We evaluated the sensitivity of Pseudomonas fluorescens strains (2-79, Q8R1, Q287) to gamma irradiation following surface inoculations on romaine lettuce and spi...

  4. Sensitivity Analysis of Fire Dynamics Simulation

    Brohus, Henrik; Nielsen, Peter V.; Petersen, Arnkell J.

    2007-01-01

    (Morris method). The parameters considered are selected among physical parameters and program specific parameters. The influence on the calculation result as well as the CPU time is considered. It is found that the result is highly sensitive to many parameters even though the sensitivity varies...

  5. Sensitivity of papaya seeds to gamma-irradiation

    Chan, Y.K.; Lam, P.F.; Abdul Rahim Harun

    2002-01-01

    The major problems faced by the papaya industry in Malaysia are the papaya ringspot virus disease and the short shelf-life of the fruit. Efforts have been made to address these problems and they include conventional breeding and selection and biotechnological tools for development of transgenic papayas with PRSV resistance and delayed fruit ripening characteristics. Irradiation-induced changes in papaya for selection of improved varieties could offer another approach to resolve these problems. As the first step, the radio-sensitivity of papaya seed must be established before mass irradiation of the materials to generate the desired variability for evaluation and selection later. For the first approximation dosage, the seeds of two local. varieties, Sekaki and Eksotika were irradiated as either dry seeds or as pre-germinated seeds (soaked overnight in water and surface-dried). The dosage ranged from 0 to 300 Gy. Wet pre-germinated seeds were all killed at 100 Gy while dry seeds did not show loss of viability even at 300 Gy. The dosage for dry seeds was raised to 1000 Gy in the following experiment and the LD 50 (or half-kill) was estimated to be 650 Gy. However, at this dosage, seedling growth was markedly reduced and this dosage may not be suitable for mass irradiation. From the growth data, it was estimated that 525 Gy was the dosage that reduced 50% of growth in height and this dosage was recommended for mass irradiation of dry seeds. For wet, pre-germinated seeds, results from the third experiment indicated that 42.5 Gy was the optimal dosage for mass irradiation. At this dosage, both seed germination and seedling growth was reduced by 50%. (Author)

  6. Sensitivity of hyperthermia-treated human cells to killing by ultraviolet or gamma radiation

    Mitchel, R.E.; Smith, B.P.; Wheatly, N.; Chan, A.; Child, S.; Paterson, M.C.

    1985-01-01

    Human xeroderma pigmentosum (XP) or Fanconi anemia (FA) fibroblasts displayed shouldered 45 0 C heat survival curves not significantly different from normal fibroblasts, a result similar to that previously found for ataxia telangiectasia (AT) cells, indicating heat resistance is not linked to either uv or low-LET ionizing radiation resistance. Hyperthermia (45 0 C) sensitized normal and XP fibroblasts to killing by gamma radiation but failed to sensitize the cells to the lethal effects of 254 nm uv radiation. Thermal inhibition of repair of ionizing radiation lesions but not uv-induced lesions appears to contribute synergistically to cell death. The thermal enhancement ratio (TER) for the synergistic interaction of hyperthermia (45 0 C, 30 min) and gamma radiation was significantly lower in one FA and two strains (TER = 1.7-1.8) than that reported previously for three normal strains (TER = 2.5-3.0). These XP and FA strains may be more gamma sensitive than normal human fibroblasts. Since hyperthermia treatment only slightly increases the gamma-radiation sensitivity of ataxia telangiectasia (AT) fibroblasts compared to normal strains, it is possible that the degree of thermal enhancement attainable reflects the genetically inherent ionizing radiation repair capacity of the cells. The data indicate that both repair inhibition and particular lesion types are required for lethal synergism between heat and radiation. We therefore postulate that the transient thermal inhibition of repair results in the conversion of gamma-induced lesions to irrepairable lethal damage, while uv-type damage can remain unaltered during this period

  7. The CTA Sensitivity to Lorentz-Violating Effects on the Gamma-Ray Horizon

    Fairbairn, Malcolm; Ellis, John; Hinton, Jim; White, Richard

    2014-01-01

    The arrival of TeV-energy photons from distant galaxies is expected to be affected by their QED interaction with intergalactic radiation fields through electron-positron pair production. In theories where high-energy photons violate Lorentz symmetry, the kinematics of the process $\\gamma + \\gamma\\rightarrow e^+ + e^-$ is altered and the cross-section suppressed. Consequently, one would expect more of the highest-energy photons to arrive if QED is modified by Lorentz violation than if it is not. We estimate the sensitivity of Cherenkov Telescope Array (CTA) to changes in the $\\gamma$-ray horizon of the Universe due to Lorentz violation, and find that it should be competitive with other leading constraints.

  8. PC based simulation of gamma camera for training of operating and maintenance staff

    Singh, B.; Kataria, S.K.; Samuel, A.M.

    2000-01-01

    Gamma camera- a sophisticated imaging system is used for functional assessment of biological subsystems/organs in nuclear medicine. The radioactive tracer attached to the native substance is injected into the patient. The distribution of radioactivity in the patient is imaged by the gamma camera. This report describes a PC based package for simulation of gamma cameras and effect of malfunctioning of its subsystems on images of different phantoms

  9. Computer simulation of sensitization in stainless steels

    Logan, R W

    1983-12-20

    Stainless steel containers are prime candidates for the containment of nuclear waste in tuff rock. The thermal history of a container involves exposure to temperatures of 500 to 600/sup 0/C when it is welded and possibly filled with molten waste glass, followed by hundreds of years exposure in the 100 to 300/sup 0/C range. The problems of short- and long-term sensitization in stainless steels have been addressed by two computer programs. The TTS program uses classical nucleation and growth theory plus experimental input to predict the onset of precipitation or sensitization under complex thermal histories. The FEMGB program uses quadratic finite-element methods to analyze diffusion processes and chromium depletion during precipitate growth. The results of studies using both programs indicate that sensitization should not be a problem in any of the austenitic stainless steels considered. However, more precise information on the process thermal cycles, especially during welding of the container, is needed. Contributions from dislocation pipe diffusion could promote long-term low-temperature sensitization.

  10. Jet simulations and gamma-ray burst afterglow jet breaks

    van Eerten, H.J.; Meliani, Z.; Wijers, R.A.M.J.; Keppens, R.

    2011-01-01

    The conventional derivation of the gamma-ray burst afterglow jet break time uses only the blast wave fluid Lorentz factor and therefore leads to an achromatic break. We show that in general gamma-ray burst afterglow jet breaks are chromatic across the self-absorption break. Depending on

  11. Jet simulations and gamma-ray burst afterglow jet breaks

    van Eerten, H. J.; Meliani, Z.; Wijers, R.A.M.J.; Keppens, R.

    2010-01-01

    The conventional derivation of the gamma-ray burst afterglow jet break time uses only the blast wave fluid Lorentz factor and therefore leads to an achromatic break. We show that in general gamma-ray burst afterglow jet breaks are chromatic across the self-absorption break. Depending on

  12. Studies of the influence of the geomagnetic field on the sensitivity of gamma-ray observatories

    Krause, Maria

    2011-02-01

    Cherenkov Telescope Array (CTA) will be a ground-based high energy gamma radiation detector. This radiation is detected by the measurement of particle showers in the atmosphere. The questions of the origin of the cosmic radiation, the functional principle of cosmic particle accelerators in the area of black holes or the nature of the dark matter are in the scientific goals of CTA. At the moment the instrument is in the planning phase and first results will probably be in 2014. The site of the instrument has an immediate influence on the sensitivity e.g. due to the weather, the height above sea level. Several possible sites for CTA are being considered at the moment including Namibia, Argentina, Canary Islands and Mexico. The geomagnetic field affects the development of showers and distorts the images of the air shower in the telescope. The aim of this work is to quantify the influence of the strength and the direction of the geomagnetic field at the different possible locations on the sensitivity of CTA using Monte Carlo simulations of particle showers. Firstly, we simulated the lateral distribution at the twelve sites. The geomagnetic field of the sites was obtained from the National Geographic Data Center (NGDC). To study the influence of the Earth's magnetic field, we held the altitude of the sites constant at 2000 m. Hence, we could choose two sites per hemisphere which could be potential candidates for the Cherenkov Telescope Array: BeaufortWest (South Africa), El Leoncito (Argentina), La Palma (Canary Islands) and San Pedro Martir (Mexico). To compare the results with a site which is already known, we chose the observatory H.E.S.S. in Namibia. After the study of the energy thresholds and the effective areas we decided in favour of two sites, one in the southern and one in the northern hemisphere. Considering the influence of the geomagnetic field on the predictions, the southern observatory should be in Beaufort West in South Africa. The northern array of CTA

  13. Studies of the influence of the geomagnetic field on the sensitivity of gamma-ray observatories

    Krause, Maria

    2011-02-15

    Cherenkov Telescope Array (CTA) will be a ground-based high energy gamma radiation detector. This radiation is detected by the measurement of particle showers in the atmosphere. The questions of the origin of the cosmic radiation, the functional principle of cosmic particle accelerators in the area of black holes or the nature of the dark matter are in the scientific goals of CTA. At the moment the instrument is in the planning phase and first results will probably be in 2014. The site of the instrument has an immediate influence on the sensitivity e.g. due to the weather, the height above sea level. Several possible sites for CTA are being considered at the moment including Namibia, Argentina, Canary Islands and Mexico. The geomagnetic field affects the development of showers and distorts the images of the air shower in the telescope. The aim of this work is to quantify the influence of the strength and the direction of the geomagnetic field at the different possible locations on the sensitivity of CTA using Monte Carlo simulations of particle showers. Firstly, we simulated the lateral distribution at the twelve sites. The geomagnetic field of the sites was obtained from the National Geographic Data Center (NGDC). To study the influence of the Earth's magnetic field, we held the altitude of the sites constant at 2000 m. Hence, we could choose two sites per hemisphere which could be potential candidates for the Cherenkov Telescope Array: BeaufortWest (South Africa), El Leoncito (Argentina), La Palma (Canary Islands) and San Pedro Martir (Mexico). To compare the results with a site which is already known, we chose the observatory H.E.S.S. in Namibia. After the study of the energy thresholds and the effective areas we decided in favour of two sites, one in the southern and one in the northern hemisphere. Considering the influence of the geomagnetic field on the predictions, the southern observatory should be in Beaufort West in South Africa. The northern array

  14. The measurement of phi 60 mm x 600 mu m silicon PIN detector gamma sensitivity and time respond

    Hu Meng Chun; Ye Wen Ying

    2002-01-01

    phi 60 mm x 600 mu m silicon PIN detector is a large area and high sensitive one which has been developed in near years. The authors have measured their gamma sensitivity and the time response. The experiment and theoretical calculated results in: sup 6 sup 0 Co gamma sensitivity is about 5 fC centre dot cm sup 2 /MeV, the rise time is about 10 ns and the half-high-width time is about 35 ns

  15. Sensitivity of P-Channel MOSFET to X- and Gamma-Ray Irradiation

    Milić Pejović

    2013-01-01

    Full Text Available Investigation of Al-gate p-channel MOSFETs sensitivity following irradiation using 200 and 280 kV X-ray beams as well as gamma-ray irradiation of 60Co in the dose range from 1 to 5 Gy was performed in this paper. The response followed on the basis of threshold voltage shift and was studied as a function of absorbed dose. It was shown that the most significant change in threshold voltage was in the case of MOSFET irradiation in X-ray fields of 200 kV and when the gate voltage was +5 V. For practical applications in dosimetry, the sensitivity of the investigated MOSFETs was also satisfactory for X-ray tube voltage of 280 kV and for gamma rays. Possible processes in gate oxide caused by radiation and its impact on the response of MOSFETs were also analyzed in this paper.

  16. Antioxidant and sensitizer effect on the stability of natural rubber latex vulcanized by gamma rays

    Canavel, V.

    1993-01-01

    The natural rubber latex was vulcanized by gamma rays and electrons beam, in the presence and absence of sensitizer at room temperature. The sensitizers were the following; n-butyl acrylate (n-BA) / t-butyl hydroperoxide (t-B H) / KOH, C Cl 4 / potassium laurate and n-BA / KOH. The studied antioxidants, Irganox 1520, Vulcanox SP and Vulcanox BKF, were added to the latex after irradiation. Among the studied antioxidants in function of tensile strength (TS) after the aging of rubber plates, the Irganox was the best efficient on the gamma vulcanization in the presence of n-BA/t-B H/KOH, because only 0,20 p hr is enough to obtain the greatest increase of TS, that was 34%, 12 MPa to 16 MPa. The formulating method of latex with the sensitizer constituted the 3,0 p hr of n-BA/ 0,1 p hr of t-B H and 0,2 p hr of KOH, was evaluated respecting the TS of rubber plates. The electrons beam vulcanization produces the greatest reversible perturbance in the colloidal stability of latex after irradiation caused by radiolytic species absorption that promotes the increase of particle size. The antioxidant also contributes to reversible destabilization of gamma irradiated latex, because it is also adsorbed by particles surface. The relation between the latex viscosity and the TS of respective rubber plates is reverse, showing the latex stability affects the quality of rubber goods. (author)

  17. Simulation of gamma irradiation system for a ballast water treatment

    Faez, T. P.; Sarkar, S.

    2006-01-01

    Invasion by different kinds of ballast the water microorganisms is one of the most important marine environment problems around the world therefore preventing the invasion of these unwanted and harmful stowaways is one of the main strategies of responsible agencies. Some of these methods such as ocean exchange, heating, filtration, hydro cyclones, UV irradiation and chemical treatment, have various problems such as technical deficiency, high costs, lack of safety and environmental side effects. Materials and Methods: A novel system of treatment by Gamma irradiation is designed to irradiate the blast water uniformly and effectively. To determine the dose distribution as a function of distance from the irradiation source, the MCNP code was used. The systems used for source implant in this simulation were Paterson-Parker, Paris and Network systems. In each system, Sivert-integral and inverse square law were used in MATLAB program to determine the dose distribution. Results: Results of initial laboratory tests on offshore water samples of Siri Island indicated that the appropriate dose for deactivation of organisms of water samples is approximately one kGy. It has been demonstrated that the dose can be provided by twenty five 100,000 Ci line sources of ' 60 Co in a triangle implant arranged in a 1*1*1 m3 cubic shape water pipe. In order to increase efficiency and radiation safety, water passed from two other coaxial and bigger cubes, after passing from the first cube. A one meter thick wall of concrete around the cubes was adequate to shield the system completely. Conclusion: The main advantages of this system such as high efficiency, safety, reliability, minimum environmental adverse effects, proves that this novel method not only can be used for ballast water treatment, but is also effective for drinking water purification

  18. Mathematical simulation of gamma-radiation angle distribution measurements

    Batij, V.G.; Batij, E.V.; Egorov, V.V.; Fedorchenko, D.V.; Kochnev, N.A.

    2008-01-01

    We developed mathematical model of the facility for gamma-radiation angle distribution measurement and calculated response functions for gamma-radiation intensities. We developed special software for experimental data processing, the 'Shelter' object radiation spectra unfolding and Sphere detector (ShD) angle resolution estimation. Neuronet method using for detection of the radiation directions is given. We developed software based on the neuronet algorithm, that allows obtaining reliable distribution of gamma-sources that make impact on the facility detectors at the measurement point. 10 refs.; 15 figs.; 4 tab

  19. Gamma-index method sensitivity for gauging plan delivery accuracy of volumetric modulated arc therapy.

    Park, Jong In; Park, Jong Min; Kim, Jung-In; Park, So-Yeon; Ye, Sung-Joon

    2015-12-01

    The aim of this study was to investigate the sensitivity of the gamma-index method according to various gamma criteria for volumetric modulated arc therapy (VMAT). Twenty head and neck (HN) and twenty prostate VMAT plans were retrospectively selected for this study. Both global and local 2D gamma evaluations were performed with criteria of 3%/3 mm, 2%/2 mm, 1%/2 mm and 2%/1 mm. In this study, the global and local gamma-index calculated the differences in doses relative to the maximum dose and the dose at the current measurement point, respectively. Using log files acquired during delivery, the differences in parameters at every control point between the VMAT plans and the log files were acquired. The differences in dose-volumetric parameters between reconstructed VMAT plans using the log files and the original VMAT plans were calculated. The Spearman's rank correlation coefficients (rs) were calculated between the passing rates and those differences. Considerable correlations with statistical significances were observed between global 1%/2 mm, local 1%/2 mm and local 2%/1 mm and the MLC position differences (rs = -0.712, -0.628 and -0.581). The numbers of rs values with statistical significance between the passing rates and the changes in dose-volumetric parameters were largest in global 2%/2 mm (n = 16), global 2%/1 mm (n = 15) and local 2%/1 mm (n = 13) criteria. Local gamma-index method with 2%/1 mm generally showed higher sensitivity to detect deviations between a VMAT plan and the delivery of the VMAT plan. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  20. Gamma radiation induced sensitization and photo-transfer in Mg2SiO4:Tb TLD phosphor

    Lakshmanan, A.R.; Vohra, K.G.

    1979-01-01

    Mg 2 SiO 4 :Tb TLD phosphor was found to show enhanced TL sensitivity to both gamma and UV radiations after high pre-gamma exposures (>100 R) and a post-annealing treatment at 300 0 C for 1 h. Maximum sensitization factors of 2.8 and 55 were obtained at the pre-expsoure levels of 5.2x10 1 C/kg and 1.3x10 3 C/kg for gamma and UV test radiations respectively. The near constancy of the intensity of the residual TL (RTL) peak at 500 0 C for the sensitized sample with increasing test-gamma exposures has ruled out the re-trapping model proposed earlier for the gamma radiation induced sensitization in this phosphor. The Tsub(max) for the sensitized phosphor was found to occur at a higher temperature compared to that for the virgin phosphor. The dependence of sensitization on RTL was explained qualitatively on the basis of competition between sensitization traps (having higher energy than the dosimetry traps) and RTL traps while capturing the charge carriers generated during the test-gamma exposure. The sensitization observed in this phosphor to UV test radiation was found to be a consequence of the photo-transfer of charge carriers from deep (RTL) traps to the shallow (dosimetry) traps. The reduction in RTL peak (500 0 C) intensity of the sensitized sample with increasing test-UV exposure has demonstrated the photo-transfer mechanism in this phosphor. The TL response of the virgin Mg 2 SiO 4 :Tb phosphor was found to be supralinear to both gamma and UV radiations. The TL response of the sensitized phosphor was found to be linear to gamma radiation and sublinear to UV radiation. (Auth.)

  1. Simulation of neutrons and gamma pulse signal and research on the pulse shape discrimination technology

    Zuo Guangxia; He Bin; Xu Peng; Qiu Xiaolin; Ma Wenyan; Li Sufen

    2012-01-01

    In neutrons detection, it is important to discriminate the neutron signals from the gamma-ray background. In this article, simulation of neutrons and gamma pulse signals is developed based on the LabVIEW platform. Two digital algorithms of the charge comparison method and the pulse duration time method are realized using 10000 simulation signals. Experimental results show that neutron and gamma pulse signals can be discriminated by the two methods, and the pulse duration time method is better than the charge comparison method. (authors)

  2. Spatial distribution of reflected gamma rays by Monte Carlo simulation

    Jehouani, A.; Merzouki, A.; Boutadghart, F.; Ghassoun, J.

    2007-01-01

    In nuclear facilities, the reflection of gamma rays of the walls and metals constitutes an unknown origin of radiation. These reflected gamma rays must be estimated and determined. This study concerns reflected gamma rays on metal slabs. We evaluated the spatial distribution of the reflected gamma rays spectra by using the Monte Carlo method. An appropriate estimator for the double differential albedo is used to determine the energy spectra and the angular distribution of reflected gamma rays by slabs of iron and aluminium. We took into the account the principal interactions of gamma rays with matter: photoelectric, coherent scattering (Rayleigh), incoherent scattering (Compton) and pair creation. The Klein-Nishina differential cross section was used to select direction and energy of scattered photons after each Compton scattering. The obtained spectra show peaks at 0.511 * MeV for higher source energy. The Results are in good agreement with those obtained by the TRIPOLI code [J.C. Nimal et al., TRIPOLI02: Programme de Monte Carlo Polycinsetique a Trois dimensions, CEA Rapport, Commissariat a l'Energie Atomique.

  3. Experimental Design for Sensitivity Analysis of Simulation Models

    Kleijnen, J.P.C.

    2001-01-01

    This introductory tutorial gives a survey on the use of statistical designs for what if-or sensitivity analysis in simulation.This analysis uses regression analysis to approximate the input/output transformation that is implied by the simulation model; the resulting regression model is also known as

  4. Sensitivity analyses for simulating pesticide impacts on honey bee colonies

    We employ Monte Carlo simulation and sensitivity analysis techniques to describe the population dynamics of pesticide exposure to a honey bee colony using the VarroaPop + Pesticide model. Simulations are performed of hive population trajectories with and without pesti...

  5. OSL sensitivity changes during single aliquot procedures: Computer simulations

    McKeever, S.W.S.; Agersnap Larsen, N.; Bøtter-Jensen, L.

    1997-01-01

    We present computer simulations of sensitivity changes obtained during single aliquot, regeneration procedures. The simulations indicate that the sensitivity changes are the combined result of shallow trap and deep trap effects. Four separate processes have been identified. Although procedures can...... be suggested to eliminate the shallow trap effects, it appears that the deep trap effects cannot be removed. The character of the sensitivity changes which result from these effects is seen to be dependent upon several external parameters, including the extent of bleaching of the OSL signal, the laboratory...

  6. Monte Carlo simulation of the Leksell Gamma Knife: I. Source modelling and calculations in homogeneous media

    Moskvin, Vadim [Department of Radiation Oncology, Indiana University School of Medicine, Indianapolis, IN (United States)]. E-mail: vmoskvin@iupui.edu; DesRosiers, Colleen; Papiez, Lech; Timmerman, Robert; Randall, Marcus; DesRosiers, Paul [Department of Radiation Oncology, Indiana University School of Medicine, Indianapolis, IN (United States)

    2002-06-21

    The Monte Carlo code PENELOPE has been used to simulate photon flux from the Leksell Gamma Knife, a precision method for treating intracranial lesions. Radiation from a single {sup 60}Co assembly traversing the collimator system was simulated, and phase space distributions at the output surface of the helmet for photons and electrons were calculated. The characteristics describing the emitted final beam were used to build a two-stage Monte Carlo simulation of irradiation of a target. A dose field inside a standard spherical polystyrene phantom, usually used for Gamma Knife dosimetry, has been computed and compared with experimental results, with calculations performed by other authors with the use of the EGS4 Monte Carlo code, and data provided by the treatment planning system Gamma Plan. Good agreement was found between these data and results of simulations in homogeneous media. Owing to this established accuracy, PENELOPE is suitable for simulating problems relevant to stereotactic radiosurgery. (author)

  7. Effects of radio sensitizers in the vulcanization of natural rubber latex induced by gamma radiation

    Souza, A. de; Canavel, V.; Araujo, S.C. de; Guedes, S.M.L.

    1992-01-01

    The effect of C Cl 4 and n-butyl acrylate as a sensitizer for radiation vulcanization of 60% DRC natural rubber latex with gamma rays, was studied relating tensile strength of vulcanized latex. The vulcanization dose is 200 kGy for natural rubber latex and it decreases to 40 kGy and to 9 kGy in the presence of C Cl 4 / potassium laureate and n-butyl acrylate / t-butyl hydroperoxide, respectively. The H 2 O 2 as a co-sensitizer does not change the efficiency of the combination of these sensitizers. The IV spectra show the formation of C=O after the irradiation as consequence of oxidation reactions. (author)

  8. Investigation of gamma-ray sensitivity of neutron detectors based on thin converter films

    Khaplanov, A; Hall-Wilton, R [European Spallation Source, P.O Box 176, SE-22100 Lund (Sweden); Piscitelli, F; Buffet, J-C; Clergeau, J-F; Correa, J; Esch, P van; Ferraton, M; Guerard, B [Institute Laue Langevin, Rue Jules Horowitz, FR-38042 Grenoble (France)

    2013-10-15

    Currently, many detector technologies for thermal neutron detection are in development in order to lower the demand for the rare {sup 3}He gas. Gas detectors with solid thin film neutron converters readout by gas proportional counter method have been proposed as an appropriate choice for applications where large area coverage is necessary. In this paper, we investigate the probability for {gamma}-rays to generate a false count in a neutron measurement. Simulated results are compared to measurement with {sup 10}B thin film prototypes and a {sup 3}He detector. It is demonstrated that equal {gamma}-ray rejection to that of {sup 3}He tubes is achieved with the new technology. The arguments and results presented here are also applicable to gas detectors with converters other than solid {sup 10}B layers, such as {sup 6}Li layers and {sup 10}BF{sub 3} gas.

  9. GEANT4 simulation study of a gamma-ray detector for neutron resonance densitometry

    Tsuchiya, Harufumi; Harada, Hideo; Koizumi, Mitsuo; Kitatani, Fumito; Takamine, Jun; Kureta, Masatoshi; Iimura, Hideki

    2013-01-01

    A design study of a gamma-ray detector for neutron resonance densitometry was made with GEANT4. The neutron resonance densitometry, combining neutron resonance transmission analysis and neutron resonance capture analysis, is a non-destructive technique to measure amounts of nuclear materials in melted fuels of the Fukushima Daiichi nuclear power plants. In order to effectively quantify impurities in the melted fuels via prompt gamma-ray measurements, a gamma-ray detector for the neutron resonance densitometry consists of cylindrical and well type LaBr 3 scintillators. The present simulation showed that the proposed gamma-ray detector suffices to clearly detect the gamma rays emitted by 10 B(n, αγ) reaction in a high environmental background due to 137 Cs radioactivity with its Compton edge suppressed at a considerably small level. (author)

  10. Gamma irradiator dose mapping simulation using the MCNP code and benchmarking with dosimetry

    Sohrabpour, M.; Hassanzadeh, M.; Shahriari, M.; Sharifzadeh, M.

    2002-01-01

    The Monte Carlo transport code, MCNP, has been applied in simulating dose rate distribution in the IR-136 gamma irradiator system. Isodose curves, cumulative dose values, and system design data such as throughputs, over-dose-ratios, and efficiencies have been simulated as functions of product density. Simulated isodose curves, and cumulative dose values were compared with dosimetry values obtained using polymethyle-methacrylate, Fricke, ethanol-chlorobenzene, and potassium dichromate dosimeters. The produced system design data were also found to agree quite favorably with those of the system manufacturer's data. MCNP has thus been found to be an effective transport code for handling of various dose mapping excercises for gamma irradiators

  11. Production of interferon-gamma by in vivo tumor-sensitized T cells: Association with active antitumor immunity

    Bursuker, I.; Pearce, M.T.

    1990-01-01

    The state of active immunity to Meth A fibrosarcoma in mice immunized with an admixture of Meth A cells and Propionibacterium acnes is associated with possession by the host of spleen cells capable of producing interferon-gamma (IFN-gamma) upon in vitro restimulation with irradiated tumor cells. The ability of spleen cells from immunized mice to produce IFN-gamma in response to irradiated Meth A cells decays as active antitumor immunity is replaced by a state of immunological memory. The IFN-producing cells are L3T4+Ly2+, cyclophosphamide-sensitive and radiosensitive T cells, as determined by their sensitivity to corresponding monoclonal antibodies and complement. The induction of IFN-gamma production by in vivo tumor-sensitized T cells is tumor specific, in that spleen cells from mice immunized against Meth A fibrosarcoma can produce IFN in response to irradiated Meth A cells but not in response to another syngeneic tumor M109 lung carcinoma

  12. Comparison of two different techniques on the human lymphocytes morphology and sensitivity to gamma radiation

    Kol, R.

    1985-02-01

    The lymphocytes in the peripheral blood are divided into two main subclasses: T cells and B cells. These differ from each other in function and in their sensitivity to radiation. The effort to study which group is more sensitive to radiation has resulted in many contradictory results. In the present study we examined whether the methods that are used to separate the lymphocytes from the whole blood, before their separation into subclasses, have an effect on the cells and whether this might contribute to the contradictory results. Blood samples were taken from several normal donors and each sample was devided into two fractions. Lymphocytes in each fraction were separated by one of the two following methods: a) sedimentation of erythrocytes by gravitation; b) separation on Ficoll-Paque density gradient. For cells obtained by these two methods, the ultrastructure was examined by electron microscopy and their ability to incorporate radioactive thymidine was measured. Samples separated on Ficoll-Paque showed a subpopulation with morphological changes similar to those occuring in lymphocytes undergoing stimulation. Unstimulated cells separated on Ficoll-Paque showed greater sensitivity to radiation. The effect of gamma radiation on the capability of lymphocytes to undergo transformation in response to three mitogens; PHA, PWM and Con A was examined. Different mitogens stimulate different lymphocytes subpopulations. There was no difference between the two separation methods regarding the sensitivity to gamma radiation of stimulation by PAH and PWM. The transformation by Con A of lymphocytes separated on Ficoll-Paque was more radiosensitive. This could indicate that the separation by Ficoll-Paque density gradient causes a selective depletion of T lymphocytes that react with Con A and are considered more radioresistant. The use of different methods for separating lymphocytes from whole blood- each has a different influence on the cells- can contribute to contradictory

  13. Enhanced gamma ray sensitivity in bismuth triiodide sensors through volumetric defect control

    Johns, Paul M.; Baciak, James E.; Nino, Juan C.

    2016-01-01

    Some of the more attractive semiconducting compounds for ambient temperature radiation detector applications are impacted by low charge collection efficiency due to the presence of point and volumetric defects. This has been particularly true in the case of BiI_3, which features very attractive properties (density, atomic number, band gap, etc.) to serve as a gamma ray detector, but has yet to demonstrate its full potential. We show that by applying growth techniques tailored to reduce defects, the spectral performance of this promising semiconductor can be realized. Gamma ray spectra from >100 keV source emissions are now obtained from high quality Sb:BiI_3 bulk crystals with limited concentrations of defects (point and extended). The spectra acquired in these high quality crystals feature photopeaks with resolution of 2.2% at 662 keV. Infrared microscopy is used to compare the local microstructure between radiation sensitive and non-responsive crystals. This work demonstrates that BiI_3 can be prepared in melt-grown detector-grade samples with superior quality and can acquire the spectra from a variety of gamma ray sources.

  14. Simulation based evaluation of the designs of the Advanced Gamma-ray Imageing System (AGIS)

    Bugaev, Slava; Buckley, James; Digel, Seth; Funk, Stephen; Konopelko, Alex; Krawczynski, Henric; Lebohec, Steohan; Maier, Gernot; Vassiliev, Vladimir

    2009-05-01

    The AGIS project under design study, is a large array of imaging atmospheric Cherenkov telescopes for gamma-rays astronomy between 40GeV and 100 TeV. In this paper we present the ongoing simulation effort to model the considered design approaches as a function of the main parameters such as array geometry, telescope optics and camera design in such a way the gamma ray observation capabilities can be optimized against the overall project cost.

  15. Monte Carlo simulation of the scattered component of neutron capture prompt gamma-ray analyzer responses

    Jin, Y.; Verghese, K.; Gardner, R.P.

    1986-01-01

    This paper describes a major part of our efforts to simulate the entire spectral response of the neutron capture prompt gamma-ray analyzer for bulk media (or conveyor belt) samples by the Monte Carlo method. This would allow one to use such a model to augment or, in most cases, essentially replace experiments in the calibration and optimum design of these analyzers. In previous work, we simulated the unscattered gamma-ray intensities, but would like to simulate the entire spectral response as we did with the energy-dispersive x-ray fluorescence analyzers. To accomplish this, one must account for the scattered gamma rays as well as the unscattered and one must have available the detector response function to translate the incident gamma-ray spectrum calculated by the Monte Carlo simulation into the detected pulse-height spectrum. We recently completed our work on the germanium detector response function, and the present paper describes our efforts to simulate the entire spectral response by using it with Monte Carlo predicted unscattered and scattered gamma rays

  16. Discrimination of irradiated MOX fuel from UOX fuel by multivariate statistical analysis of simulated activities of gamma-emitting isotopes

    Åberg Lindell, M.; Andersson, P.; Grape, S.; Hellesen, C.; Håkansson, A.; Thulin, M.

    2018-03-01

    This paper investigates how concentrations of certain fission products and their related gamma-ray emissions can be used to discriminate between uranium oxide (UOX) and mixed oxide (MOX) type fuel. Discrimination of irradiated MOX fuel from irradiated UOX fuel is important in nuclear facilities and for transport of nuclear fuel, for purposes of both criticality safety and nuclear safeguards. Although facility operators keep records on the identity and properties of each fuel, tools for nuclear safeguards inspectors that enable independent verification of the fuel are critical in the recovery of continuity of knowledge, should it be lost. A discrimination methodology for classification of UOX and MOX fuel, based on passive gamma-ray spectroscopy data and multivariate analysis methods, is presented. Nuclear fuels and their gamma-ray emissions were simulated in the Monte Carlo code Serpent, and the resulting data was used as input to train seven different multivariate classification techniques. The trained classifiers were subsequently implemented and evaluated with respect to their capabilities to correctly predict the classes of unknown fuel items. The best results concerning successful discrimination of UOX and MOX-fuel were acquired when using non-linear classification techniques, such as the k nearest neighbors method and the Gaussian kernel support vector machine. For fuel with cooling times up to 20 years, when it is considered that gamma-rays from the isotope 134Cs can still be efficiently measured, success rates of 100% were obtained. A sensitivity analysis indicated that these methods were also robust.

  17. Simulation of COMEDIE Fission Product Plateout Experiment Using GAMMA-FP

    Tak, Nam-il; Yoon, Churl

    2014-01-01

    FThis phenomenon is particularly important under a VHTR design with vented low pressure confinement (VLPC), because the vent allows the prompt release of fission products accumulated within the primary circuit to environment during an initial blow-down phase after pipe break accidents. In order to analyze the fission product plateout, an numerical model was developed by Yoo et al. and incorporated into the GAMMA-FP code in the past. The GAMMA-FP model was validated against two experiment data, i.e., VAMPYR-1 and OGL, during the development phase. One of the well-known experiments for fission product plateout is the COMEDIE experiment. In this work, the COMEDIE experiment has been simulated using the GAMMA-FP code to investigate the reliability and applicability of the plateout model of GAMMA-FP. The COMEDIE experiment for fission product plateout was simulated using the GAMMA-FP code in this work. A good agreement was achieved between the measured and predicted plateout activities. The existing solution scheme was modified to allow larger time step size for fission product analysis in order to speed-up the computational time. Nevertheless, the modification of the existing numerical model of GAMMA-FP is necessary when a simulation capability of a long duration of plateout period (e.g., 60 years) is targeted

  18. Generating Correlated Gamma Sequences for Sea-Clutter Simulation

    2012-03-01

    generation of correlated Gamma random fields via SIRP theory is examined in [Conte et al. 1991, Armstrong & Griffiths 1991]. In these papers , the Gamma...2 〉2 + |〈x[n]x∗[n+ k]〉|2 . (4) Because 〈 |x|2 〉2 = z̄2 and |〈x[n]x∗[n+ k]〉|2 ≥ 0, this results in 〈z[n]z[n+ k]〉 ≥ z̄2 if the real- isation of z[n] is...linear map- ping. In a practical situation, a process with a given auto-covariance function would be specified. It is shown that by using an

  19. Single-acquisition method for simultaneous determination of extrinsic gamma-camera sensitivity and spatial resolution

    Santos, J.A.M. [Servico de Fisica Medica, Instituto Portugues de Oncologia Francisco Gentil do Porto, E.P.E., Rua Dr. Antonio Bernardino de Almeida, 4200-072 Porto (Portugal)], E-mail: a.miranda@portugalmail.pt; Sarmento, S. [Servico de Fisica Medica, Instituto Portugues de Oncologia Francisco Gentil do Porto, E.P.E., Rua Dr. Antonio Bernardino de Almeida, 4200-072 Porto (Portugal); Alves, P.; Torres, M.C. [Departamento de Fisica da Universidade do Porto, Rua do Campo Alegre 687, 4169-007 Porto (Portugal); Bastos, A.L. [Servico de Medicina Nuclear, Instituto Portugues de Oncologia Francisco Gentil do Porto, E.P.E., Rua Dr. Antonio Bernardino de Almeida, 4200-072 Porto (Portugal); Ponte, F. [Servico de Fisica Medica, Instituto Portugues de Oncologia Francisco Gentil do Porto, E.P.E., Rua Dr. Antonio Bernardino de Almeida, 4200-072 Porto (Portugal)

    2008-01-15

    A new method for measuring simultaneously both the extrinsic sensitivity and spatial resolution of a gamma-camera in a single planar acquisition was implemented. A dual-purpose phantom (SR phantom; sensitivity/resolution) was developed, tested and the results compared with other conventional methods used for separate determination of these two important image quality parameters. The SR phantom yielded reproducible and accurate results, allowing an immediate visual inspection of the spatial resolution as well as the quantitative determination of the contrast for six different spatial frequencies. It also proved to be useful in the estimation of the modulation transfer function (MTF) of the image formation collimator/detector system at six different frequencies and can be used to estimate the spatial resolution as function of the direction relative to the digital matrix of the detector.

  20. Single-acquisition method for simultaneous determination of extrinsic gamma-camera sensitivity and spatial resolution

    Santos, J.A.M.; Sarmento, S.; Alves, P.; Torres, M.C.; Bastos, A.L.; Ponte, F.

    2008-01-01

    A new method for measuring simultaneously both the extrinsic sensitivity and spatial resolution of a gamma-camera in a single planar acquisition was implemented. A dual-purpose phantom (SR phantom; sensitivity/resolution) was developed, tested and the results compared with other conventional methods used for separate determination of these two important image quality parameters. The SR phantom yielded reproducible and accurate results, allowing an immediate visual inspection of the spatial resolution as well as the quantitative determination of the contrast for six different spatial frequencies. It also proved to be useful in the estimation of the modulation transfer function (MTF) of the image formation collimator/detector system at six different frequencies and can be used to estimate the spatial resolution as function of the direction relative to the digital matrix of the detector

  1. Simulation of prompt gamma rays spectra: calibration for pollutants determination in voluminous samples

    Khelifi, R.; Idiri, Z.; Amokrane, A.; Bode, P.

    2006-01-01

    A PGNAA facility using Am-Be source has been developed with the aim of analyzing the major composition of various elements in aqueous samples. A program of simulation for gamma rays spectra was developed to estimate the detection limits of pollutants. The background line under photo peaks of interest was simulated using experimental data. The reliability of the program was checked under real conditions with solutions containing various salt concentrations. Experimental and simulated spectra were found to be in good agreement. (author)

  2. Discrete Event Simulation Model of the Polaris 2.1 Gamma Ray Imaging Radiation Detection Device

    2016-06-01

    release; distribution is unlimited DISCRETE EVENT SIMULATION MODEL OF THE POLARIS 2.1 GAMMA RAY IMAGING RADIATION DETECTION DEVICE by Andres T...ONLY (Leave blank) 2. REPORT DATE June 2016 3. REPORT TYPE AND DATES COVERED Master’s thesis 4. TITLE AND SUBTITLE DISCRETE EVENT SIMULATION MODEL...modeled. The platform, Simkit, was utilized to create a discrete event simulation (DES) model of the Polaris. After carefully constructing the DES

  3. Simulation of a multi-detector gamma camera for validation protocols of quantification the activity from SPECT images

    Lozano Sanchez, A.; Calderon Marin, C.; Gonzalez Gonzalez, J.

    2015-01-01

    The main sources that decreasing accuracy in the estimation of internal absorbed dose has been identified in the methods for the quantification of cumulated activity from scintigraphic imaging, likes the corrections required by the physical and instrumental phenomena related to the formation of those images. The results of the simulation of a dual detector gamma camera E.cam SIEMENS using the Monte Carlo code SIMIND to obtain tomographic SPECT projections are presented here. SIMIND will allow dealing with the contribution of physical interactions and instrumental effects during simulations. Energy resolution, spatial resolution and sensitivity planar were determined with real and simulated systems. The relative differences did not exceed 10%. Energy spectra simulated under different conditions (source in air and water) with the inclusion of interactions in the collimator and phantom were compared. The tomographic sensitivity of a volumetric phantom containing radioactive solutions of 99m Tc and 131 I were determined from real and simulated SPECT images. Two processing protocols were considered: with scatter correction ( 99m Tc dual energy window method and 131 I were calculated after corrections. The results, expressed in terms of the differences relative to the well-know activity value in the phantom inserts improves when attenuation and scattering corrections are applied, obtaining good agreement between the results for real and simulated systems. (Author)

  4. Sensitivity analysis for oblique incidence reflectometry using Monte Carlo simulations

    Kamran, Faisal; Andersen, Peter E.

    2015-01-01

    profiles. This article presents a sensitivity analysis of the technique in turbid media. Monte Carlo simulations are used to investigate the technique and its potential to distinguish the small changes between different levels of scattering. We present various regions of the dynamic range of optical...

  5. Rethinking Sensitivity Analysis of Nuclear Simulations with Topology

    Dan Maljovec; Bei Wang; Paul Rosen; Andrea Alfonsi; Giovanni Pastore; Cristian Rabiti; Valerio Pascucci

    2016-01-01

    In nuclear engineering, understanding the safety margins of the nuclear reactor via simulations is arguably of paramount importance in predicting and preventing nuclear accidents. It is therefore crucial to perform sensitivity analysis to understand how changes in the model inputs affect the outputs. Modern nuclear simulation tools rely on numerical representations of the sensitivity information -- inherently lacking in visual encodings -- offering limited effectiveness in communicating and exploring the generated data. In this paper, we design a framework for sensitivity analysis and visualization of multidimensional nuclear simulation data using partition-based, topology-inspired regression models and report on its efficacy. We rely on the established Morse-Smale regression technique, which allows us to partition the domain into monotonic regions where easily interpretable linear models can be used to assess the influence of inputs on the output variability. The underlying computation is augmented with an intuitive and interactive visual design to effectively communicate sensitivity information to the nuclear scientists. Our framework is being deployed into the multi-purpose probabilistic risk assessment and uncertainty quantification framework RAVEN (Reactor Analysis and Virtual Control Environment). We evaluate our framework using an simulation dataset studying nuclear fuel performance.

  6. Sensitivity analysis of high resolution gamma-ray detection for safeguards monitoring at natural uranium conversion facilities

    Dewji, S.A., E-mail: dewjisa@ornl.gov [Oak Ridge National Laboratory, PO Box 2008 MS-6335, Oak Ridge TN 37831 (United States); Georgia Institute of Technology, 770 State Street, Atlanta, GA 30332-0745 (United States); Croft, S. [Oak Ridge National Laboratory, PO Box 2008 MS-6335, Oak Ridge TN 37831 (United States); Hertel, N.E. [Oak Ridge National Laboratory, PO Box 2008 MS-6335, Oak Ridge TN 37831 (United States); Georgia Institute of Technology, 770 State Street, Atlanta, GA 30332-0745 (United States)

    2017-03-11

    Under the policies proposed by recent International Atomic Energy Agency (IAEA) circulars and policy papers, implementation of safeguards exists when any purified aqueous uranium solution or uranium oxides suitable for isotopic enrichment or fuel fabrication exists. Under IAEA Policy Paper 18, the starting point for nuclear material under safeguards was reinterpreted, suggesting that purified uranium compounds should be subject to safeguards procedures no later than the first point in the conversion process. In response to this technical need, a combination of simulation models and experimental measurements were employed in previous work to develop and validate gamma-ray nondestructive assay monitoring systems in a natural uranium conversion plant (NUCP). In particular, uranyl nitrate (UO{sub 2}(NO{sub 3}){sub 2}) solution exiting solvent extraction was identified as a key measurement point (KMP). Passive nondestructive assay techniques using high resolution gamma-ray spectroscopy were evaluated to determine their viability as a technical means for drawing safeguards conclusions at NUCPs, and if the IAEA detection requirements of 1 significant quantity (SQ) can be met in a timely manner. Building upon the aforementioned previous validation work on detector sensitivity to varying concentrations of uranyl nitrate via a series of dilution measurements, this work investigates detector response parameter sensitivities to gamma-ray signatures of uranyl nitrate. The full energy peak efficiency of a detection system is dependent upon the sample, geometry, absorption, and intrinsic efficiency parameters. Perturbation of these parameters translates into corresponding variations of the 185.7 keV peak area of the {sup 235}U in uranyl nitrate. Such perturbations in the assayed signature impact the quality or versatility of the safeguards conclusions drawn. Given the potentially high throughput of uranyl nitrate in NUCPs, the ability to assay 1 SQ of material requires

  7. Repair of gamma radiation damage in wild type and a radiation sensitive mutant of Deinococcus radiodurans

    Mizuma, Nagayo

    1989-01-01

    In an effort to examine production and repair of radiation-induced single and double strand breaks in the DNA, a repair-deficient wild type and a repair-deficient mutant, UV17, of Deinococcus radiodurans were subjected to Co-60 gamma irradiation at a dose rate of 6.3 kGy/hr for wild type and 3.9 kGy/hr for UV17 mutant. The shoulder of the curve of UV17 mutant was narrow but existed with the intercept of 0.7 kGy and the corresponding value of the wild type was 4.2 kGy. Mutant cells exhibited about 6 fold increases in sensitivity for the shoulder relative to the wild type. The D 37 doses in the wild type and the mutant were 0.57 kGy and 0.25 kGy, respectively. From the survival curves, difference in the sensitivity between two strains was mainly due to difference of repair capacity than the number of radiation sensitive target. Sedimentation rate of the main component in the irradiated cells of UV17 mutant increased almost to the level of unirradiated control by the postincubation at 30deg C for 3 hrs. The results indicated that this sensitive mutant also exhibited an ability to restore single strand breaks after exposure to a sublethal dose of 0.6 kGy. When restitution of double strand breaks was analyzed by sedimentation in a neutral sucrose gradient, the wild type showed restitution to DNA-membrane complex from large part of the breaks. For UV17 mutant, the apparent increase in DNA-membrane complex formation was seen after 3 hours incubation. Large part of the decrease in the activities of peak 2 was recovered in the peak 1 for the wild type. For the mutant, there was little restitution to peak 1. Almost free DNA component in UV17 mutant, therefore, was merely degraded into shorter pieces. Restoration of DNA-membrane complex from free DNA derived from gamma-ray induced double strand scission involved closely in the repair of gamma-induced damage and survival. (N.K.)

  8. Reset charge sensitive amplifier for NaI(Tl) gamma-ray spectrometer

    Zeng, Guoqiang; Tan, Chengjun; Li, Qiang; Ge, Liangquan; Liu, Xiyao; Luo, Qun

    2015-01-01

    The time constant of the output signal of the front-end readout circuit of a traditional gamma-ray spectrometer with a NaI(Tl)+PMT structure is affected by temperature, measurement environment and the signal transmission cable, so it is difficult to get a good resolution spectrum, especially at higher counting rates. In this paper, a reset charge sensitive amplifier (RCSA) is designed for the gamma-ray spectrometer with a NaI(Tl)+PMT structure. The designed RCSA outputs a step signal, thus enabling the acquisition of double-exponential signals with a stable time constant by using the next stage of a CR differentiating circuit. The designed RCSA is mainly composed of a basic amplifying circuit, a reset circuit and a dark current compensation circuit. It provides the output step signal through the integration of the PMT output charge signal. When the amplitude of the step signal exceeds a preset voltage threshold, it triggers the reset circuit to generate a reset pulse (about 5 µs pulse width) to reset the output signal. Experimental results demonstrated that the designed RCSA achieves a charge sensitivity of 4.26×10 10 V/C, with a zero capacitance noise of 51.09 fC and a noise slope of 1.98 fC/pF. Supported by the digital shaping algorithm of the digital multi-channel analyzer (DMCA), it can maintain good energy resolution with high counting rates up to 150 kcps and with a temperature range from −19 °C to 50 °C. - Highlights: • A new reset type charge sensitive amplifier for gamma-ray spectrometer based on a photomultiplier tube is proposed. • Reset circuit formed by constant current source output a fixed width pulse to reset charge sensitive amplifier. • Photomultiplier tube dark current compensation circuit could increase the pulse through rate by decreasing reset frequency. • This amplifier outputs a step function signal that could match next stage circuit easily

  9. Simulation of Neutron-Induced Prompt Gamma-ray Spectra Emitted from Fake Tungsten Gold Bar

    Lee, K. M.; Sum, G. M. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    Fake gold bars on the market cannot be identified easily without testing because they have the same appearance as a pure gold bar. A non-destructive monitoring method is needed to avoid the trading of fake gold bars on the market. The ultimate goal of this study is to find a fake gold bar detection method using a PGAA (Prompt Gamma Activation Analysis). Using existing data, the number of neutron capture for gold and tungsten in fake tungsten gold bar was calculated and a Monte Carlo simulation for the prompt neutron-induced gamma-ray spectra was conducted. A simulation for neutron-induced prompt gamma-rays spectra when a neutron beam is irradiated onto pure and fake gold bars was successfully conducted. Through a comparison between the prompt gamma-ray spectra of the pure gold bar and those of the fake gold bar, it was concluded that the observation of prompt high-energy gamma-rays from tungsten or a reduction of prompt gamma-rays from gold can be evidence of a fake gold bar. The possibility for detecting a fake gold bar using a PGAA facility was verified.

  10. Simulation of Neutron-Induced Prompt Gamma-ray Spectra Emitted from Fake Tungsten Gold Bar

    Lee, K. M.; Sum, G. M.

    2016-01-01

    Fake gold bars on the market cannot be identified easily without testing because they have the same appearance as a pure gold bar. A non-destructive monitoring method is needed to avoid the trading of fake gold bars on the market. The ultimate goal of this study is to find a fake gold bar detection method using a PGAA (Prompt Gamma Activation Analysis). Using existing data, the number of neutron capture for gold and tungsten in fake tungsten gold bar was calculated and a Monte Carlo simulation for the prompt neutron-induced gamma-ray spectra was conducted. A simulation for neutron-induced prompt gamma-rays spectra when a neutron beam is irradiated onto pure and fake gold bars was successfully conducted. Through a comparison between the prompt gamma-ray spectra of the pure gold bar and those of the fake gold bar, it was concluded that the observation of prompt high-energy gamma-rays from tungsten or a reduction of prompt gamma-rays from gold can be evidence of a fake gold bar. The possibility for detecting a fake gold bar using a PGAA facility was verified

  11. Simulation Study on Identifiability of UHE Gamma-ray Air Showers

    Wada, Y.; Inoue, N.; Miyazawa, K.; Vankov, H.P.

    2008-01-01

    The chemical composition of Ultra-High-Energy (UHE) comic rays is one of unsolved mysteries, and its study will give us fruitful information on the origin and acceleration mechanism of UHE cosmic rays. Especially, a detection of UHE gamma-rays by hybrid experiments, such as AUGER and TA, will be a key to solve these questions. The characteristics of UHE gamma-ray showers have been studied by comparing the lateral and longitudinal structures of shower particles calculated with AIRES and our own simulation code, so far. There are apparent differences in a slope of lateral distribution (η) and a depth of shower maximum (Xmax) between gamma-ray and proton induced showers because UHE gamma-ray showers are affected by the LPM effect and the geomagnetic cascading process in an energy region of >10 19.5 eV. Different features between gamma-ray and proton showers are pointed out from the simulation study and an identifiability of gamma-ray showers from proton ones is also discussed by the method of Neural-Network-Analysis

  12. Simulation Study on Identifiability of UHE Gamma-ray Air Showers

    Wada, Y.; Inoue, N.; Miyazawa, K. [Graduate School of Science and Engineering, Saitama University, Saitama 338-8570 (Japan); Vankov, H.P. [Institute for Nuclear Research and Nuclear Energy, Bulgaria Academy, Sofia (Bulgaria)

    2008-01-15

    The chemical composition of Ultra-High-Energy (UHE) comic rays is one of unsolved mysteries, and its study will give us fruitful information on the origin and acceleration mechanism of UHE cosmic rays. Especially, a detection of UHE gamma-rays by hybrid experiments, such as AUGER and TA, will be a key to solve these questions. The characteristics of UHE gamma-ray showers have been studied by comparing the lateral and longitudinal structures of shower particles calculated with AIRES and our own simulation code, so far. There are apparent differences in a slope of lateral distribution ({eta}) and a depth of shower maximum (Xmax) between gamma-ray and proton induced showers because UHE gamma-ray showers are affected by the LPM effect and the geomagnetic cascading process in an energy region of >10{sup 19.5}eV. Different features between gamma-ray and proton showers are pointed out from the simulation study and an identifiability of gamma-ray showers from proton ones is also discussed by the method of Neural-Network-Analysis.

  13. Monte Carlo simulations of prompt-gamma emission during carbon ion irradiation

    Le Foulher, F.; Bajard, M.; Chevallier, M.; Dauvergne, D.; Henriquet, P.; Ray, C.; Testa, E.; Testa, M. [Universite de Lyon 1, F-69003 Lyon (France); IN2P3/CNRS, UMR 5822, Institut de Physique Nucleaire de Lyon, F-69622 Villeurbanne (France); Freud, N.; Letang, J. M. [Laboratoire de Controles Non Destructifs Par Rayonnements Ionisants, INSA-Lyon, F-69621 Villeurbanne cedex (France); Karkar, S. [CPPM, Aix-Marseille Universite, CNRS/IN2P3, Marseille (France); Plescak, R.; Schardt, D. [Gesellschaft fur Schwerionenforschung (GSI), D-64291 Darmstadt (Germany)

    2009-07-01

    Monte Carlo simulations based on the Geant4 tool-kit (version 9.1) were performed to study the emission of secondary prompt gamma-rays produced by nuclear reactions during carbon ion-beam therapy. These simulations were performed along with an experimental program and instrumentation developments which aim at designing a prompt gamma-ray device for real-time control of hadron therapy. The objective of the present study is twofold: first, to present the features of the prompt gamma radiation in the case of carbon ion irradiation; secondly, to simulate the experimental setup and to compare measured and simulated counting rates corresponding to various experiments. For each experiment, we found that simulations overestimate prompt gamma-ray detection yields by a factor of 12. Uncertainties in fragmentation cross sections and binary cascade model cannot explain such discrepancies. The so-called 'photon evaporation' model is therefore questionable and its modification is currently in progress. (authors)

  14. Carbon dioxide capture processes: Simulation, design and sensitivity analysis

    Zaman, Muhammad; Lee, Jay Hyung; Gani, Rafiqul

    2012-01-01

    equilibrium and associated property models are used. Simulations are performed to investigate the sensitivity of the process variables to change in the design variables including process inputs and disturbances in the property model parameters. Results of the sensitivity analysis on the steady state...... performance of the process to the L/G ratio to the absorber, CO2 lean solvent loadings, and striper pressure are presented in this paper. Based on the sensitivity analysis process optimization problems have been defined and solved and, a preliminary control structure selection has been made.......Carbon dioxide is the main greenhouse gas and its major source is combustion of fossil fuels for power generation. The objective of this study is to carry out the steady-state sensitivity analysis for chemical absorption of carbon dioxide capture from flue gas using monoethanolamine solvent. First...

  15. Statistical analysis for discrimination of prompt gamma ray peak induced by high energy neutron: Monte Carlo simulation study

    Do-Kun Yoon; Joo-Young Jung; Tae Suk Suh; Seong-Min Han

    2015-01-01

    The purpose of this research is a statistical analysis for discrimination of prompt gamma ray peak induced by the 14.1 MeV neutron particles from spectra using Monte Carlo simulation. For the simulation, the information of 18 detector materials was used to simulate spectra by the neutron capture reaction. The discrimination of nine prompt gamma ray peaks from the simulation of each detector material was performed. We presented the several comparison indexes of energy resolution performance depending on the detector material using the simulation and statistics for the prompt gamma activation analysis. (author)

  16. A simulation study on the dose distribution for a single beam of the gamma knife

    Chen, Chin-cheng; Jiang, Shiang-Huei; Lee, Chung-chi; Shiau, Cheng-Ying

    2000-01-01

    The purpose of this study is to evaluate the impact of the tissue heterogeneity on the dose distribution for a single beam of the gamma knife. The EGS4 Monte Carlo code was used to simulate both depth and radial profiles of the radiation dose in homogeneous and heterogeneous phantoms, respectively. The results are compared with the dose distribution calculated using the mathematical model of Gamma Plan, the treatment planning system of the gamma knife. The skull and sinus heterogeneity were simulated by a Teflon shell and an air shell, respectively. It was found that the tissue heterogeneity caused significant perturbation on the absolute depth dose at the focus as well as on the depth-dose distribution near the phantom surface and/or at the interface but little effect on the radial dose distribution. The effect of the beam aperture on the depth-dose distribution was also investigated in this study. (author)

  17. Monte Carlo simulation for the design of industrial gamma-ray transmission tomography

    Kim, Jongbum; Jung, Sunghee; Moon, Jinho; Kwon, Taekyong; Cho, Gyuseong

    2011-01-01

    The Monte Carlo simulation and experiment were carried out for a large-scale industrial gamma ray tomographic scanning geometry. The geometry of the tomographic system has a moving source with 16 stationary detectors. This geometry is advantageous for the diagnosis of a large-scale industrial plant. The simulation data was carried out for the phantom with 32 views, 16 detectors, and a different energy bin. The simulation data was processed to be used for image reconstruction. Image reconstruction was performed by a Diagonally-Scaled Gradient-Ascent algorithm for simulation data. Experiments were conducted in a 78 cm diameter column filled with polypropylene grains. Sixteen 0.5-inch-thick and 1 inch long NaI(Tl) cylindrical detectors, and 20 mCi of 137 Cs radioactive source were used. The experimental results were compared to the simulation data. The experimental results were similar to Monte Carlo simulation results. This result showed that the Monte Carlo simulation is useful for predicting the result of the industrial gamma tomographic scan method And it can also give a solution for designing the industrial gamma tomography system and preparing the field experiment. (author)

  18. Effects of food diets on insect development and its sensitivity to gamma radiation

    Khattak, S.U.; Azhar, A.; Shahid, M.

    2004-01-01

    Taking red flour beetle, Tribolium castaneum (Herbst), as a study case, studies on the effect of different food diets on insect development and losses and its sensitivity to gamma radiation, were conducted under controlled laboratory conditions. The results revealed that all the three major parameters (development, losses and sensitivity) varied significantly (P< 0.05) with respect to fed diet. Developmental period was highest (43.5 days) in wheat starch and lowest (22 days) in wheat flour + 5% yeast (Standard diet). A significantly highest progeny (948) was produced in barley and lowest (105.3) in wheat starch. Maximum adult weight (37.35 mg/20 adults) was recorded in sorghum and minimum (33.4) in starch. Percent weight loss was highest (21.25) in barley and lowest (8.0) in starch. Barley flour was found as the most preferred diet. Radiosensitivity in relation to diet indicated that adults reared on wheat starch were most sensitive. Comparing the dose response, insect mortality was dose, diet and post irradiation duration dependent. However, 2.5kGy proved quite lethal. No significant effect of radiation was observed on moisture and protein contents of the diets, except reducing sugars. (author)

  19. Sensitivity of root-knot nematodes to gamma irradiation, salinity and plant growth regulator, cycocel

    Sweelam, M E [Econ. Entomology Dept., Fac. Agric. Menoufia University Shebin El-Kom, (Egypt)

    1995-10-01

    The experiment was carried out at the experimental station of the faculty of agriculture, Menoufia Univ. To determine the sensitivity of root-knot nematode, Meloidogyne Javanica infecting tomato plants exposed to different doses of gamma irradiation 0,20,40,60,80 Gy, salinity levels 0. 1000, 2000, 4000 ppm and the plant growth regulator cycocel 0,200 ppm. Treated seeds were planted clay pots and salinity levels and cycocel concentrations were applied. Fresh weights and nematode populations were computed 3 months after application. Results indicated that 20 Gy, 1000 ppm salinity and cycocel gave the highest fresh weight of shoots and roots. The developmental stages and egg-laying females of nematode decreased by the increasing of irradiation dose and salinity levels. Root-knot galls decreased with 40 and 60 Gy, while significant increase was observed with 0 and 80 Gy, salinity levels decreased root galls. Cycocel decreased nematode population, egg-lying females and root-knot galls.

  20. Kinetic Degradation and Controlled Drug Delivery System Studies for Sensitive Hydrogels Prepared by Gamma Irradiation

    Eid, M.; El-Arnaouty, M.B.

    2008-01-01

    Ternary mixtures of N-vinyle-2-pyrrolidone(NVP ), itaconic acid (IA) and gelatin (G) were gamma irradiated to prepared poly(NVP/IA/G) hydrogels. The equilibrium kinetic swelling, drug release behavior, Scan Electron Microscope (SEM) and the swelling-degradation kinetics were studied. Both the diffusion exponent and the diffusion coefficient increase with increasing content of (IA). Also, the swelling behavior of copolymer hydrogels in response to ph value of the external media was studied, it is noted that the highest swelling values at ph 4. The in vitro drug release behavior of these hydrogels was examined by quantification analysis with a UV/VIS spectrophotometers. Chlorpromazine hydrochloride was loaded into dried hydrogels to investigate the stimuli-sensitive property at the specific ph. The release studies show that the highest value of release was at ph 4 which can be used for drug delivery system

  1. Sensitivity of root-knot nematodes to gamma irradiation, salinity and plant growth regulator, cycocel

    Sweelam, M.E.

    1995-01-01

    The experiment was carried out at the experimental station of the faculty of agriculture, Menoufia Univ. To determine the sensitivity of root-knot nematode, Meloidogyne Javanica infecting tomato plants exposed to different doses of gamma irradiation 0,20,40,60,80 Gy, salinity levels 0. 1000, 2000, 4000 ppm and the plant growth regulator cycocel 0,200 ppm. Treated seeds were planted clay pots and salinity levels and cycocel concentrations were applied. Fresh weights and nematode populations were computed 3 months after application. Results indicated that 20 Gy, 1000 ppm salinity and cycocel gave the highest fresh weight of shoots and roots. The developmental stages and egg-laying females of nematode decreased by the increasing of irradiation dose and salinity levels. Root-knot galls decreased with 40 and 60 Gy, while significant increase was observed with 0 and 80 Gy, salinity levels decreased root galls. Cycocel decreased nematode population, egg-lying females and root-knot galls

  2. AGATA gamma-ray tracking simulations and data analysis working group

    NONE

    2007-07-01

    The purpose of this meeting was to review the present state of the AGATA project (Advanced GAmma Tracking Array). The following issues were dealt with: -) detectors and preamplifiers, -) ancillary detectors, -) tracking, -) physics simulations and key experiments, -) in-beam tests, -) data acquisition, -) data processing: front end electronics, and -) infrastructure. This document gathers only the slides of the presentations.

  3. AGATA gamma-ray tracking simulations and data analysis working group

    2007-01-01

    The purpose of this meeting was to review the present state of the AGATA project (Advanced GAmma Tracking Array). The following issues were dealt with: -) detectors and preamplifiers, -) ancillary detectors, -) tracking, -) physics simulations and key experiments, -) in-beam tests, -) data acquisition, -) data processing: front end electronics, and -) infrastructure. This document gathers only the slides of the presentations

  4. A virtual source method for Monte Carlo simulation of Gamma Knife Model C

    Kim, Tae Hoon; Kim, Yong Kyun [Hanyang University, Seoul (Korea, Republic of); Chung, Hyun Tai [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2016-05-15

    The Monte Carlo simulation method has been used for dosimetry of radiation treatment. Monte Carlo simulation is the method that determines paths and dosimetry of particles using random number. Recently, owing to the ability of fast processing of the computers, it is possible to treat a patient more precisely. However, it is necessary to increase the simulation time to improve the efficiency of accuracy uncertainty. When generating the particles from the cobalt source in a simulation, there are many particles cut off. So it takes time to simulate more accurately. For the efficiency, we generated the virtual source that has the phase space distribution which acquired a single gamma knife channel. We performed the simulation using the virtual sources on the 201 channel and compared the measurement with the simulation using virtual sources and real sources. A virtual source file was generated to reduce the simulation time of a Gamma Knife Model C. Simulations with a virtual source executed about 50 times faster than the original source code and there was no statistically significant difference in simulated results.

  5. A virtual source method for Monte Carlo simulation of Gamma Knife Model C

    Kim, Tae Hoon; Kim, Yong Kyun; Chung, Hyun Tai

    2016-01-01

    The Monte Carlo simulation method has been used for dosimetry of radiation treatment. Monte Carlo simulation is the method that determines paths and dosimetry of particles using random number. Recently, owing to the ability of fast processing of the computers, it is possible to treat a patient more precisely. However, it is necessary to increase the simulation time to improve the efficiency of accuracy uncertainty. When generating the particles from the cobalt source in a simulation, there are many particles cut off. So it takes time to simulate more accurately. For the efficiency, we generated the virtual source that has the phase space distribution which acquired a single gamma knife channel. We performed the simulation using the virtual sources on the 201 channel and compared the measurement with the simulation using virtual sources and real sources. A virtual source file was generated to reduce the simulation time of a Gamma Knife Model C. Simulations with a virtual source executed about 50 times faster than the original source code and there was no statistically significant difference in simulated results

  6. Comparison of penumbra regions produced by ancient Gamma knife model C and Gamma ART 6000 using Monte Carlo MCNP6 simulation.

    Banaee, Nooshin; Asgari, Sepideh; Nedaie, Hassan Ali

    2018-07-01

    The accuracy of penumbral measurements in radiotherapy is pivotal because dose planning computers require accurate data to adequately modeling the beams, which in turn are used to calculate patient dose distributions. Gamma knife is a non-invasive intracranial technique based on principles of the Leksell stereotactic system for open deep brain surgeries, invented and developed by Professor Lars Leksell. The aim of this study is to compare the penumbra widths of Leksell Gamma Knife model C and Gamma ART 6000. Initially, the structure of both systems were simulated by using Monte Carlo MCNP6 code and after validating the accuracy of simulation, beam profiles of different collimators were plotted. MCNP6 beam profile calculations showed that the penumbra values of Leksell Gamma knife model C and Gamma ART 6000 for 18, 14, 8 and 4 mm collimators are 9.7, 7.9, 4.3, 2.6 and 8.2, 6.9, 3.6, 2.4, respectively. The results of this study showed that since Gamma ART 6000 has larger solid angle in comparison with Gamma Knife model C, it produces better beam profile penumbras than Gamma Knife model C in the direct plane. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Simulating Visibility Under Reduced Acuity and Contrast Sensitivity

    Thompson, William B.; Legge, Gordon E.; Kersten, Daniel J.; Shakespeare, Robert A.; Lei, Quan

    2017-01-01

    Architects and lighting designers have difficulty designing spaces that are accessible to those with low vision, since the complex nature of most architectural spaces requires a site-specific analysis of the visibility of mobility hazards and key landmarks needed for navigation. We describe a method that can be utilized in the architectural design process for simulating the effects of reduced acuity and contrast on visibility. The key contribution is the development of a way to parameterize the simulation using standard clinical measures of acuity and contrast sensitivity. While these measures are known to be imperfect predictors of visual function, they provide a way of characterizing general levels of visual performance that is familiar to both those working in low vision and our target end-users in the architectural and lighting design communities. We validate the simulation using a letter recognition task. PMID:28375328

  8. QCD jet simulation with CMS at LHC and background studies to H to gamma gamma process

    Litvin, V; Shevchenko, S; Wisniewski, N

    2002-01-01

    We have simulated and reconstructed one million of QCD jet events. This study was done with CMS full detector simulation, based on GEANT3 package, and object-oriented CMS C++ reconstruction program. The understanding of QCD jet background is important for the Higgs search in two-photon decay mode. The comparison with other types of backgrounds was also done. It was shown that the isolation tools were important ones to isolate the signal process from the huge background one. Using the isolation criteria based on the information from PbWO /sub 4/ electromagnetic calorimeter and the tracker we were able to reduce the QCD jet background to 15% of the total one. (9 refs).

  9. Composite space charge density functions for the calculation of gamma sensitivity of self-powered neutron detectors, using Warren's model

    Mahant, A. K.; Rao, P. S.; Misra, S. C.

    1994-07-01

    In the calculational model developed by Warren and Shah for the computation of the gamma sensitivity ( Sγ) it has been observed that the computed Sγ value is quite sensitive to the space charge distribution function assumed for the insulator region and the energy of the gamma photons. The Sγ of SPNDs with Pt, Co and V emitters (manufactured by Thermocoax, France) has been measured at 60Co photon energy and a good correlation between the measured and computed values has been obtained using a composite space charge density function (CSCD), the details of which are presented in this paper. The arguments are extended for evaluating the Sγ values of several SPNDs for which Warren and Shah reported the measured values for a prompt fission gamma spectrum obtained in a swimming pool reactor. These results are also discussed.

  10. A 3D simulation look-up library for real-time airborne gamma-ray spectroscopy

    Kulisek, Jonathan A.; Wittman, Richard S.; Miller, Erin A.; Kernan, Warnick J.; McCall, Jonathon D.; McConn, Ron J.; Schweppe, John E.; Seifert, Carolyn E.; Stave, Sean C.; Stewart, Trevor N.

    2018-01-01

    A three-dimensional look-up library consisting of simulated gamma-ray spectra was developed to leverage, in real-time, the abundance of data provided by a helicopter-mounted gamma-ray detection system consisting of 92 CsI-based radiation sensors and exhibiting a highly angular-dependent response. We have demonstrated how this library can be used to help effectively estimate the terrestrial gamma-ray background, develop simulated flight scenarios, and to localize radiological sources. Source localization accuracy was significantly improved, particularly for weak sources, by estimating the entire gamma-ray spectra while accounting for scattering in the air, and especially off the ground.

  11. Simulators of tray distillation columns as tools for interpreting gamma-ray scan profile signal

    Offei-Mensah, P.S.; Gbadago, J.K.; Dagadu, C.P.K.; Danso, K.A.

    2008-01-01

    Simulators of tray distillation columns were used to provide technical guidelines for interpreting signals from gamma ray scans used for analysing malfunctions in distillation columns. The transmitted radiation intensities at 0.05 m intervals were determined from top to bottom of simulators of tray distillation columns exposed to 20 mCi of '1'3'7 Cs. Signals generated from the simulators were identical with the experimental signals obtained from the stabilizer column of the crude oil distillation unit at the Tema Oil Refinery Ghana Limited. Changes in the signal level were observed with changes in diameter, type of material (gasoline, air, debris, steel) and orientation of scan line. The analysis provided accurate interpretation of gamma scan profiles. (au)

  12. Capability for identification of gamma-irradiated bovine liver by new high sensitivity comet assay

    Miyahara, Makoto; Toyoda, Masatake; Saito, Akiko; Ito, Hitoshi

    2000-01-01

    DNA in food will sustain damage by gamma radiation. The detection capability of the high sensitivity comet assay was studied using fluorescence-microscopy. Beef liver was irradiated at a range of 1 Gy to 8 kGy. Single cells were obtained from the irradiated liver, then analyzed by agaros-gel electrophoresis. The pH of the buffer for electrophoresis was pH 13, which is generally utilized for sensitive detection of DNA damage. The pattern formed by DNA was visualized by staining with ethidium bromide. The resulting comets were evaluated with a scale we developed, and Influence Scores were calculated based on the Tice method. It is possible to detect irradiation damage to beef liver at 10 Gy. Together with Influence Score, histogram of comet type is used for detection of irradiation. We elucidated those histograms were useful for distinguishing damage caused by irradiation from that of others. DNA damage can be caused not only by irradiation, but also by the other treatments. Therefore, the respective influences of freezing, preservation, irradiating temperature, atmosphere of irradiation, cooking, and homogenizing devices were also examined. This new comet assay will be a useful method of detecting DNA damage to identify irradiated foods. (author)

  13. A general sensitivity theory for simulations of nonlinear systems

    Kenton, M.A.

    1981-01-01

    A general sensitivity theory is developed for nonlinear lumped-parameter system simulations. The point-of-departure is general perturbation theory, which has long been used for linear systems in nuclear engineering and reactor physics. The theory allows the sensitivity of particular figures-of-merit of the system behavior to be calculated with respect to any parameter.An explicit procedure is derived for applying the theory to physical systems undergoing sudden events (e.g., reactor scrams, tank ruptures). A related problem, treating figures-of-merit defined as functions of extremal values of system variables occurring at sudden events, is handled by the same procedure. The general calculational scheme for applying the theory to numerical codes is discussed. It is shown that codes which use pre-packaged implicit integration subroutines can be augmented to include sensitivity theory: a companion set of subroutines to solve the sensitivity problem is listed. This combined system analysis code is applied to a simple model for loss of post-accident heat removal in a liquid metal-cooled fast breeder reactor. The uses of the theory for answering more general sensitivity questions are discussed. One application of the theory is to systematically determine whether specific physical processes in a model contribute significantly to the figures-of-merit. Another application of the theory is for selecting parameter values which enable a model to match experimentally observed behavior

  14. Effect of Long Term Low-Level Gamma Radiation on Thermal Sensitivity of RDX/HMX Mixtures

    1976-11-01

    1.1x10 R. It was concluded that the slight exothermic reaction before the 3^6 HMX polymorphic transition could be caused by a radiation-induced...Radiation on Thermal Sensitivity of RDX / HMX Mixtures 5. TYPE OF REPORT 4 PERIOD COVERED Final Report 6. PERFORMING ORG. REPORT NUMBER 7...and Identity by block number) Gamma radiation Weight loss HMX Impact sensitivity test RDX Vacuum stability test DTA Infrared spectrometry TGA

  15. Simulation of Prompt gamma-rays spectra: Calibration for water tables pollutants determination

    Khelifi, R.; Idiri, Z.; Amokrane, A.; Bode, P.

    2006-01-01

    Full text of publication follows: A PGNAA facility using Am-Be source has been developed with the aim of analyzing the major composition of various elements in aqueous sample. A program of simulation for gamma rays spectra was developed to estimate the detection limits of pollutants. The background line under photo-peaks of interest was simulated by using experimental data. The reliability of the program is checked on real condition with solutions contained various salt concentration. Comparison between experimental and simulated spectra was found in good agreement. (authors)

  16. Constraining Gamma-Ray Pulsar Gap Models with a Simulated Pulsar Population

    Pierbattista, Marco; Grenier, I. A.; Harding, A. K.; Gonthier, P. L.

    2012-01-01

    With the large sample of young gamma-ray pulsars discovered by the Fermi Large Area Telescope (LAT), population synthesis has become a powerful tool for comparing their collective properties with model predictions. We synthesised a pulsar population based on a radio emission model and four gamma-ray gap models (Polar Cap, Slot Gap, Outer Gap, and One Pole Caustic). Applying gamma-ray and radio visibility criteria, we normalise the simulation to the number of detected radio pulsars by a select group of ten radio surveys. The luminosity and the wide beams from the outer gaps can easily account for the number of Fermi detections in 2 years of observations. The wide slot-gap beam requires an increase by a factor of 10 of the predicted luminosity to produce a reasonable number of gamma-ray pulsars. Such large increases in the luminosity may be accommodated by implementing offset polar caps. The narrow polar-cap beams contribute at most only a handful of LAT pulsars. Using standard distributions in birth location and pulsar spin-down power (E), we skew the initial magnetic field and period distributions in a an attempt to account for the high E Fermi pulsars. While we compromise the agreement between simulated and detected distributions of radio pulsars, the simulations fail to reproduce the LAT findings: all models under-predict the number of LAT pulsars with high E , and they cannot explain the high probability of detecting both the radio and gamma-ray beams at high E. The beaming factor remains close to 1.0 over 4 decades in E evolution for the slot gap whereas it significantly decreases with increasing age for the outer gaps. The evolution of the enhanced slot-gap luminosity with E is compatible with the large dispersion of gamma-ray luminosity seen in the LAT data. The stronger evolution predicted for the outer gap, which is linked to the polar cap heating by the return current, is apparently not supported by the LAT data. The LAT sample of gamma-ray pulsars

  17. Mesh refinement of simulation with the AID riser transmission gamma

    Lima Filho, Hilario J.B. de; Benachour, Mohand; Dantas, Carlos C.; Brito, Marcio F.P.; Santos, Valdemir A. dos

    2013-01-01

    Type reactors Circulating Fluidized Bed (CFBR) vertical, in which the particulate and gaseous phases have flows upward (riser) have been widely used in gasification processes, combustion and fluid catalytic cracking (FCC). These biphasic reactors (gas-solid) efficiency depends largely on their hydrodynamic characteristics, and shows different behaviors in the axial and radial directions. The solids axial distribution is observed by the higher concentration in the base, getting more diluted toward the top. Radially, the solids concentration is characterized as core-annular, in which the central region is highly diluted, consisting of dispersed particles and fluid. In the present work developed a two-dimensional geometry (2D) techniques through simulations in computational fluid dynamics (CFD) to predict the gas-solid flow in the riser type CFBR through transient modeling, based on the kinetic theory of granular flow . The refinement of computational meshes provide larger amounts of information on the parameters studied, but may increase the processing time of the simulations. A minimum number of cells applied to the mesh construction was obtained by testing five meshes. The validation of the hydrodynamic parameters was performed using a range of 241Am source and detector NaI (Tl). The numerical results were provided consistent with the experimental data, indicating that the refined computational mesh in a controlled manner, improve the approximation of the expected results. (author)

  18. On the Efficient Simulation of the Distribution of the Sum of Gamma-Gamma Variates with Application to the Outage Probability Evaluation Over Fading Channels

    Ben Issaid, Chaouki

    2017-01-26

    The Gamma-Gamma distribution has recently emerged in a number of applications ranging from modeling scattering and reverberation in sonar and radar systems to modeling atmospheric turbulence in wireless optical channels. In this respect, assessing the outage probability achieved by some diversity techniques over this kind of channels is of major practical importance. In many circumstances, this is related to the difficult question of analyzing the statistics of a sum of Gamma- Gamma random variables. Answering this question is not a simple matter. This is essentially because outage probabilities encountered in practice are often very small, and hence the use of classical Monte Carlo methods is not a reasonable choice. This lies behind the main motivation of the present work. In particular, this paper proposes a new approach to estimate the left tail of the sum of Gamma-Gamma variates. More specifically, we propose robust importance sampling schemes that efficiently evaluates the outage probability of diversity receivers over Gamma-Gamma fading channels. The proposed estimators satisfy the well-known bounded relative error criterion for both maximum ratio combining and equal gain combining cases. We show the accuracy and the efficiency of our approach compared to naive Monte Carlo via some selected numerical simulations.

  19. On the Efficient Simulation of the Distribution of the Sum of Gamma-Gamma Variates with Application to the Outage Probability Evaluation Over Fading Channels

    Ben Issaid, Chaouki

    2016-06-01

    The Gamma-Gamma distribution has recently emerged in a number of applications ranging from modeling scattering and reverbation in sonar and radar systems to modeling atmospheric turbulence in wireless optical channels. In this respect, assessing the outage probability achieved by some diversity techniques over this kind of channels is of major practical importance. In many circumstances, this is intimately related to the difficult question of analyzing the statistics of a sum of Gamma-Gamma random variables. Answering this question is not a simple matter. This is essentially because outage probabilities encountered in practice are often very small, and hence the use of classical Monte Carlo methods is not a reasonable choice. This lies behind the main motivation of the present work. In particular, this paper proposes a new approach to estimate the left tail of the sum of Gamma-Gamma variates. More specifically, we propose a mean-shift importance sampling scheme that efficiently evaluates the outage probability of L-branch maximum ratio combining diversity receivers over Gamma-Gamma fading channels. The proposed estimator satisfies the well-known bounded relative error criterion, a well-desired property characterizing the robustness of importance sampling schemes, for both identically and non-identically independent distributed cases. We show the accuracy and the efficiency of our approach compared to naive Monte Carlo via some selected numerical simulations.

  20. On the Efficient Simulation of the Distribution of the Sum of Gamma-Gamma Variates with Application to the Outage Probability Evaluation Over Fading Channels

    Ben Issaid, Chaouki; Ben Rached, Nadhir; Kammoun, Abla; Alouini, Mohamed-Slim; Tempone, Raul

    2016-01-01

    The Gamma-Gamma distribution has recently emerged in a number of applications ranging from modeling scattering and reverbation in sonar and radar systems to modeling atmospheric turbulence in wireless optical channels. In this respect, assessing the outage probability achieved by some diversity techniques over this kind of channels is of major practical importance. In many circumstances, this is intimately related to the difficult question of analyzing the statistics of a sum of Gamma-Gamma random variables. Answering this question is not a simple matter. This is essentially because outage probabilities encountered in practice are often very small, and hence the use of classical Monte Carlo methods is not a reasonable choice. This lies behind the main motivation of the present work. In particular, this paper proposes a new approach to estimate the left tail of the sum of Gamma-Gamma variates. More specifically, we propose a mean-shift importance sampling scheme that efficiently evaluates the outage probability of L-branch maximum ratio combining diversity receivers over Gamma-Gamma fading channels. The proposed estimator satisfies the well-known bounded relative error criterion, a well-desired property characterizing the robustness of importance sampling schemes, for both identically and non-identically independent distributed cases. We show the accuracy and the efficiency of our approach compared to naive Monte Carlo via some selected numerical simulations.

  1. Two Dimensional Verification of the Dose Distribution of Gamma Knife Model C using Monte Carlo Simulation with a Virtual Source

    Kim, Tae-Hoon; Kim, Yong-Kyun; Lee, Cheol Ho; Son, Jaebum; Lee, Sangmin; Kim, Dong Geon; Choi, Joonbum; Jang, Jae Yeong [Hanyang University, Seoul (Korea, Republic of); Chung, Hyun-Tai [Seoul National University, Seoul (Korea, Republic of)

    2016-10-15

    Gamma Knife model C contains 201 {sup 60}Co sources located on a spherical surface, so that each beam is concentrated on the center of the sphere. In the last work, we simulated the Gamma Knife model C through Monte Carlo simulation code using Geant4. Instead of 201 multi-collimation system, we made one single collimation system that collects source parameter passing through the collimator helmet. Using the virtual source, we drastically reduced the simulation time to transport 201 gamma circle beams to the target. Gamma index has been widely used to compare two dose distributions in cancer radiotherapy. Gamma index pass rates were compared in two calculated results using the virtual source method and the original method and measured results obtained using radiocrhomic films. A virtual source method significantly reduces simulation time of a Gamma Knife Model C and provides equivalent absorbed dose distributions as that of the original method showing Gamma Index pass rate close to 100% under 1mm/3% criteria. On the other hand, it gives a little narrow dose distribution compared to the film measurement showing Gamma Index pass rate of 94%. More accurate and sophisticated examination on the accuracy of the simulation and film measurement is necessary.

  2. Self-absorption corrections of various sample-detector geometries in gamma-ray spectrometry using sample Monte Carlo Simulations

    Ahmad Saat; Appleby, P.G.; Nolan, P.J.

    1997-01-01

    Corrections for self-absorption in gamma-ray spectrometry have been developed using a simple Monte Carlo simulation technique. The simulation enables the calculation of gamma-ray path lengths in the sample which, using available data, can be used to calculate self-absorption correction factors. The simulation was carried out on three sample geometries: disk, Marinelli beaker, and cylinder (for well-type detectors). Mathematical models and experimental measurements are used to evaluate the simulations. A good agreement of within a few percents was observed. The simulation results are also in good agreement with those reported in the literature. The simulation code was carried out in FORTRAN 90,

  3. Stochastic sensitivity analysis and Langevin simulation for neural network learning

    Koda, Masato

    1997-01-01

    A comprehensive theoretical framework is proposed for the learning of a class of gradient-type neural networks with an additive Gaussian white noise process. The study is based on stochastic sensitivity analysis techniques, and formal expressions are obtained for stochastic learning laws in terms of functional derivative sensitivity coefficients. The present method, based on Langevin simulation techniques, uses only the internal states of the network and ubiquitous noise to compute the learning information inherent in the stochastic correlation between noise signals and the performance functional. In particular, the method does not require the solution of adjoint equations of the back-propagation type. Thus, the present algorithm has the potential for efficiently learning network weights with significantly fewer computations. Application to an unfolded multi-layered network is described, and the results are compared with those obtained by using a back-propagation method

  4. Sensitivity of tropical cyclone simulations to microphysics parameterizations in WRF

    Reshmi Mohan, P.; Srinivas, C.V.; Bhaskaran, R.; Venkatraman, B.; Yesubabu, V.

    2018-01-01

    Tropical cyclones (TC) cause storm surge along coastal areas where these storms cross the coast. As major nuclear facilities are usually installed in coastal region, the surge predictions are highly important for DAE. The critical TC parameters needed in estimating storm surge are intensity (winds, central pressure and radius of maximum winds) and storm tracks. The predictions with numerical models are generally made by representing the clouds and precipitation processes using convective and microphysics parameterization. At high spatial resolutions (1-3Km) microphysics can act as cloud resolving NWP model to explicitly resolve the convective precipitation without using convection schemes. Recent simulation studies using WRF on severe weather phenomena such as thunderstorms and hurricanes indicated large sensitivity of predicted rainfall and hurricane tracks to microphysics due to variation in temperature and pressure gradients which generate winds that determine the storm track. In the present study the sensitivity of tropical cyclone tracks and intensity to different microphysics schemes has been conducted

  5. HCIT Contrast Performance Sensitivity Studies: Simulation Versus Experiment

    Sidick, Erkin; Shaklan, Stuart; Krist, John; Cady, Eric J.; Kern, Brian; Balasubramanian, Kunjithapatham

    2013-01-01

    Using NASA's High Contrast Imaging Testbed (HCIT) at the Jet Propulsion Laboratory, we have experimentally investigated the sensitivity of dark hole contrast in a Lyot coronagraph for the following factors: 1) Lateral and longitudinal translation of an occulting mask; 2) An opaque spot on the occulting mask; 3) Sizes of the controlled dark hole area. Also, we compared the measured results with simulations obtained using both MACOS (Modeling and Analysis for Controlled Optical Systems) and PROPER optical analysis programs with full three-dimensional near-field diffraction analysis to model HCIT's optical train and coronagraph.

  6. Simulation of Resistive Plate Chamber sensitivity to neutrons

    Altieri, S. E-mail: saverio.altieri@pv.infn.it; Belli, G.; Bruno, G.; Merlo, M.; Ratti, S.P.; Riccardi, C.; Torre, P.; Vitulo, P.; Abbrescia, M.; Colaleo, A.; Iaselli, G.; Loddo, F.; Maggi, M.; Marangelli, B.; Natali, S.; Nuzzo, S.; Pugliese, G.; Ranieri, A.; Romano, F

    2001-04-01

    The Resistive Plate Chambers (RPCs) sensitivity to neutrons has been simulated using GEANT code with MICAP and FLUKA interfaces. The calculations have been performed as a function of the neutrons energy in the range 0.02 eV-1 GeV. To evaluate the response of the detector in the LHC background environment, the neutron energy spectrum expected in the CMS muon barrel has been taken into account; a hit rate due to neutrons of about 0.6 Hz cm{sup -2} has been estimated for a 250x250 cm{sup 2} RPC in the RB1 station.

  7. The Advanced Gamma-ray Imageing System (AGIS): Simulation Design Studies

    Bugaev, V.; Buckley, J.; Digel, S.; Fegan, S.; Funk, S.; Konopelko, A.; Krawczynski, H.; Lebohec, S.; Maier, G.; Vassiliev, V.

    2008-04-01

    We present design studies for AGIS, a proposed array of ˜100 imaging atmospheric Cherenkov telescopes for gamma-rays astronomy in the 40GeV to 100 TeV energy regime. We describe optimization studies for the array configuration, pixel size and field of view aimed at achieving the best sensitivity over the entire energy range and best angular resolution for a fixed project total cost.

  8. Evaluation of DNA damage induced by gamma radiation in gill and muscle tissues of Cyprinus carpio and their relative sensitivity.

    M K, Praveen Kumar; Shyama, Soorambail K; D'Costa, Avelyno; Kadam, Samit B; Sonaye, Bhagatsingh Harisingh; Chaubey, Ramesh Chandra

    2017-10-01

    The effect of radiation on the aquatic environment is of major concern in recent years. Limited data is available on the genotoxicity of gamma radiation on different tissues of aquatic organisms. Hence, the present investigation was carried out to study the DNA damage induced by gamma radiation in the gill and muscle tissues and their relative sensitivity using the comet assay in the freshwater teleost fish, common carp (Cyprinus carpio). The comet assay was optimized and validated in common carp using cyclophosphamide (CP), a reference genotoxic agent. The fish were exposed (acute) to various doses of gamma radiation (2, 4, 6, 8 and 10Gy) and samplings (gill and muscle tissue) were done at regular intervals (24, 48 and 72h) to assess the DNA damage. A significant increase in DNA damage was observed as indicated by an increase in % tail DNA for all doses of gamma radiation in both tissues. We also observed a dose-related increase and a time-dependent decrease of DNA damage. In comparison, DNA damage showed different sensitivity among the tissues at different doses. This shows that a particular dose may have different effects on different tissues which could be due to physiological factors of the particular tissue. Our study also suggests that the gills and muscle of fish are sensitive and reliable tissues for evaluating the genotoxic effects of reference and environmental agents, using the comet assay. Copyright © 2017. Published by Elsevier Inc.

  9. Simulation of the spherical experimental assemblies for the mixed neutron-gamma reference fields implementation

    Kluson, J.; Jansky, B.

    2009-01-01

    Reference mixed neutron-gamma fields are used for test and calibration of dosimetric and spectrometric systems, intercomparison measurements, and benchmark tests and represent experimental base for reactor studies. Set of the spherical experimental assemblies for the mixed neutron-gamma reference fields implementation was build in the NRI Rez. Extended sets of measurements and simulation calculations were done to describe the reference mixed field dosimetry and spectral characteristics with best achievable precision. The Monte Carlo technique was used for different experimental setups models description, comparison and verification and field characteristics simulation. Effects (hardly distinguishable experimentally) were also studied ( contributions from individual parts of experimental setup, field individual components and next effects as shadow shield cones transparency, etc.). Some results and main conclusions of these studies and calculations are presented and discussed. (authors)

  10. Simulation of the spherical experimental assemblies for the mixed neutron-gamma reference fields implementation

    Kluson, J.; Jansky, B.

    2008-01-01

    Reference mixed neutron-gamma fields are used for test and calibration of dosimetric and spectrometric systems, intercomparison measurements, and benchmark tests and represent experimental base for reactor studies. Set of the spherical experimental assemblies for the mixed neutron-gamma reference fields implementation was build in the NRI Rez. Extended sets of measurements and simulation calculations were done to describe the reference mixed field dosimetry and spectral characteristics with best achievable precision. The Monte Carlo technique was used for different experimental setups models description, comparison and verification and field characteristics simulation. Effects (hardly distinguishable experimentally) were also studied ( contributions from individual parts of experimental setup, field individual components and next effects as shadow shield cones transparency, etc.). Some results and main conclusions of these studies and calculations are presented and discussed. (authors)

  11. Sensitivity of T lymphocytes to gamma rays in patients with cervix tumor

    Oueslati, R; Kdous, CH; Chouikha, M [Lab. Immunology, Hopital de Tunis, (Tunisia); Maalej, M; Kochbati, N [Service Radiotherapy, Institut Salah Azeiz, (Tunisia)

    1995-10-01

    In this work we studied the effect of radiotherapy on normal cells in patients with cervix tumors treated only by gamma rays. In our laboratory, after lymphocytes separation, we tested the proliferation system of these cells against the phytohemagglutinin and the concanavalin a antigens; at the same time we tested their sensitivity to lys the erythroid tumor cells line K 562. According to the clinical stage of disease the 25 patients studied were divided in two groups; group I composed of 14 patients at stage I and II proximal, received 50 Gy from a cesium 137 source, in intrauterine and in continuous treatment during 4 days. The second group composed of 11 patients at stage II distal and III, received 50 Gy from a cobalt-60 source in extra uterine, the treatment is fractioned in 3 to 5 times per week, at each time the patient received 1,5 - 3 Gy. To compare with their immunological status before treatment, until 1 month after total dose received, all of our patients lost transitory their capacity to prolifere in vitro. Although the capacity to lys the tumor cells is diminished in cancer patients, the drop of this activity is principally. The selective recuperation of T lymphocytes stimulated by concanavalin A is also observed. 3 figs., 2 tabs.

  12. Sensitivity of T lymphocytes to gamma rays in patients with cervix tumor

    Oueslati, R.; Kdous, CH.; Chouikha, M.; Maalej, M.; Kochbati, N.

    1995-01-01

    In this work we studied the effect of radiotherapy on normal cells in patients with cervix tumors treated only by gamma rays. In our laboratory, after lymphocytes separation, we tested the proliferation system of these cells against the phytohemagglutinin and the concanavalin a antigens; at the same time we tested their sensitivity to lys the erythroid tumor cells line K 562. According to the clinical stage of disease the 25 patients studied were divided in two groups; group I composed of 14 patients at stage I and II proximal, received 50 Gy from a cesium 137 source, in intrauterine and in continuous treatment during 4 days. The second group composed of 11 patients at stage II distal and III, received 50 Gy from a cobalt-60 source in extra uterine, the treatment is fractioned in 3 to 5 times per week, at each time the patient received 1,5 - 3 Gy. To compare with their immunological status before treatment, until 1 month after total dose received, all of our patients lost transitory their capacity to prolifere in vitro. Although the capacity to lys the tumor cells is diminished in cancer patients, the drop of this activity is principally. The selective recuperation of T lymphocytes stimulated by concanavalin A is also observed. 3 figs., 2 tabs

  13. Application of Monte Carlo method in forward simulation of azimuthal gamma imaging while drilling

    Yuan Chao; Zhou Cancan; Zhang Feng; Chen Zhi

    2014-01-01

    Monte Carlo simulation is one of the most important numerical simulation methods in nuclear logging. Formation models can be conveniently built with MCNP code, which provides a simple and effective approach for fundamental study of nuclear logging. Monte Carlo method is employed to set up formation models under logging while drilling condition, and the characteristic of azimuthal gamma imaging is simulated. The results present that the azimuthal gamma imaging shows a sinusoidal curve features. The imaging can be used to accurately calculate the relative dip angle of borehole and thickness of radioactive formation. The larger relative dip angle of borehole and the thicker radioactive formation lead to the larger height of the sinusoidal curve in the imaging. The borehole size has no affect for the calculation of the relative dip angle, but largely affects the determination of formation thickness. The standoff of logging tool has great influence for the calculation of the relative dip angle and formation thickness. If the gamma ray counts meet the demand of counting statistics in nuclear logging, the effect of borehole fluid on the imaging can be ignored. (authors)

  14. Simulated gamma-ray pulse profile of the Crab pulsar with the Cherenkov Telescope Array

    Burtovoi, A.; Zampieri, L.

    2016-07-01

    We present simulations of the very high energy (VHE) gamma-ray light curve of the Crab pulsar as observed by the Cherenkov Telescope Array (CTA). The CTA pulse profile of the Crab pulsar is simulated with the specific goal of determining the accuracy of the position of the interpulse. We fit the pulse shape obtained by the Major Atmospheric Gamma-Ray Imaging Cherenkov (MAGIC) telescope with a three-Gaussian template and rescale it to account for the different CTA instrumental and observational configurations. Simulations are performed for different configurations of CTA and for the ASTRI (Astrofisica con Specchi a Tecnologia Replicante Italiana) mini-array. The northern CTA configuration will provide an improvement of a factor of ˜3 in accuracy with an observing time comparable to that of MAGIC (73 h). Unless the VHE spectrum above 1 TeV behaves differently from what we presently know, unreasonably long observing times are required for a significant detection of the pulsations of the Crab pulsar with the high-energy-range sub-arrays. We also found that an independent VHE timing analysis is feasible with Large Size Telescopes. CTA will provide a significant improvement in determining the VHE pulse shape parameters necessary to constrain theoretical models of the gamma-ray emission of the Crab pulsar. One of such parameters is the shift in phase between peaks in the pulse profile at VHE and in other energy bands that, if detected, may point to different locations of the emission regions.

  15. Monte Carlo simulation of {beta}-{gamma} coincidence system using plastic scintillators in 4{pi} geometry

    Dias, M.S. [Instituto de Pesquisas Energeticas e Nucleares: IPEN-CNEN/SP, Av. Prof. Lineu Prestes 2242, 05508-000 Sao Paulo, SP (Brazil)], E-mail: msdias@ipen.br; Piuvezam-Filho, H. [Instituto de Pesquisas Energeticas e Nucleares: IPEN-CNEN/SP, Av. Prof. Lineu Prestes 2242, 05508-000 Sao Paulo, SP (Brazil); Baccarelli, A.M. [Departamento de Fisica-PUC/SP-Rua Marques de Paranagua 111, 01303-050 Sao Paulo, SP (Brazil); Takeda, M.N. [Universidade Santo Amaro, UNISA-Rua Prof. Eneas da Siqueira Neto 340, 04829-300 Sao Paulo, SP (Brazil); Koskinas, M.F. [Instituto de Pesquisas Energeticas e Nucleares: IPEN-CNEN/SP, Av. Prof. Lineu Prestes 2242, 05508-000 Sao Paulo, SP (Brazil)

    2007-09-21

    A modified version of a Monte Carlo code called Esquema, developed at the Nuclear Metrology Laboratory in IPEN, Sao Paulo, Brazil, has been applied for simulating a 4{pi}{beta}(PS)-{gamma} coincidence system designed for primary radionuclide standardisation. This system consists of a plastic scintillator in 4{pi} geometry, for alpha or electron detection, coupled to a NaI(Tl) counter for gamma-ray detection. The response curves for monoenergetic electrons and photons have been calculated previously by Penelope code and applied as input data to code Esquema. The latter code simulates all the disintegration processes, from the precursor nucleus to the ground state of the daughter radionuclide. As a result, the curve between the observed disintegration rate as a function of the beta efficiency parameter can be simulated. A least-squares fit between the experimental activity values and the Monte Carlo calculation provided the actual radioactive source activity, without need of conventional extrapolation procedures. Application of this methodology to {sup 60}Co and {sup 133}Ba radioactive sources is presented and showed results in good agreement with a conventional proportional counter 4{pi}{beta}(PC)-{gamma} coincidence system.

  16. Application of simulated standard spectra in natural radioactivity measurements using gamma spectrometry

    Narayani, K.; Pant, A.D.; Bhosle, Nitin; Anilkumar, S.; Singh, Rajvir; Pradeepkumar, K.S.

    2014-01-01

    Gamma ray spectrometry is one of the well known analytical techniques for environmental radioactivity measurements. Gamma spectrometer based on NaI(Tl) scintillation detectors is very popular since it offers high efficiency, low cost and case in handling. The poor energy resolution of the NaI(TI) detector is the major disadvantage making tile analysis of complex gamma ray spectra difficult. Least square method or the full spectrum analysis method is widely used for the analysis of complex spectra from scintillation detectors. The main requirement of this method is that the individual standard spectra of all nuclides expected in the complex spectrum in the same measurement geometry must be available. It is not always possible and feasible to have all the standards of nuclides in the desired geometry. A methodology based on the use of simulated standard spectra generated by Monte Carlo technique was proposed for analysis of complex spectra of nuclides. In the present work, for the analysis of 238 U, 233 Th and 40 K in soil samples, the same methodology was applied by using the simulated standard spectra in soil matrix. The details of the simulation method and results analysis of 238 U, 232 Th and 40 K in environmental samples are discussed in this paper

  17. Applicability and sensitivity of gamma transmission and radiotracer techniques for mineral scaling studies

    Bjoernstad, Tor; Stamatakis, Emanuel

    2006-05-15

    Mineral scaling in petroleum and geothermal production systems creates a substantial problem of flow impairment. It is a priority to develop methods for scale inhibition. To study scaling rates and mechanisms in laboratory flow experiments under simulated reservoir conditions two nuclear methods have been introduced and tested. The first applies the principle of gamma transmission to measure mass increase. Here, we use a 30 MBq source of 133Ba. The other method applies radioactive tracers of one or more of the scaling components. We have used the study of CaC03-precipitation, as an example of the applicability of the method where the main tracer used is 47Ca2+. While the first method must be regarded as an indirect method, the latter is a direct method where the reactions of specific components may be studied. Both methods are on-line, continuous and non-destructive, and capable to study scaling of liquids with saturation ratios as low as SR=1.5 or lower. A lower limit of detection for the transmission method in sand-packed columns with otherwise reasonable experimental parameters is less than 1 mg CaC03 in a 1 cm section of the tube packed with silica sand SiO2. A lower limit of detection for the tracer method with reasonable experimental parameters is less than 1 microgram in the same tube section. (author) (tk)

  18. Applicability and sensitivity of gamma transmission and radiotracer techniques for mineral scaling studies

    Bjoernstad, Tor; Stamatakis, Emanuel

    2006-05-01

    Mineral scaling in petroleum and geothermal production systems creates a substantial problem of flow impairment. It is a priority to develop methods for scale inhibition. To study scaling rates and mechanisms in laboratory flow experiments under simulated reservoir conditions two nuclear methods have been introduced and tested. The first applies the principle of gamma transmission to measure mass increase. Here, we use a 30 MBq source of 133Ba. The other method applies radioactive tracers of one or more of the scaling components. We have used the study of CaC03-precipitation, as an example of the applicability of the method where the main tracer used is 47Ca2+. While the first method must be regarded as an indirect method, the latter is a direct method where the reactions of specific components may be studied. Both methods are on-line, continuous and non-destructive, and capable to study scaling of liquids with saturation ratios as low as SR=1.5 or lower. A lower limit of detection for the transmission method in sand-packed columns with otherwise reasonable experimental parameters is less than 1 mg CaC03 in a 1 cm section of the tube packed with silica sand SiO2. A lower limit of detection for the tracer method with reasonable experimental parameters is less than 1 microgram in the same tube section. (author) (tk)

  19. Sensitive detection of aerosol effect on simulated IASI spectral radiance

    Quan, X.; Huang, H.-L.; Zhang, L.; Weisz, E.; Cao, X.

    2013-01-01

    Guided by radiative transfer modeling of the effects of dust (aerosol) on satellite thermal infrared radiance by many different imaging radiometers, in this article, we present the aerosol-effected satellite radiative signal changes in the top of atmosphere (TOA). The simulation of TOA radiance for Infrared Atmospheric Sounding Interferometer (IASI) is performed by using the RTTOV fast radiative transfer model. The model computation is carried out with setting representative geographical atmospheric models and typical default aerosol climatological models under clear sky condition. The radiative differences (in units of equivalent black body brightness temperature differences (BTDs)) between simulated radiances without consideration of the impact of aerosol (Aerosol-free) and with various aerosol models (Aerosol-modified) are calculated for the whole IASI spectrum between 3.62 and 15.5 μm. The comparisons of BTDs are performed through 11 aerosol models in 5 classified atmospheric models. The results show that the Desert aerosol model has the most significant impact on IASI spectral simulated radiances than the other aerosol models (Continental, Urban, Maritime types and so on) in Mid-latitude Summer, contributing to the mineral aerosol components contained. The value of BTDs could reach up to 1 K at peak points. The atmospheric window spectral region between 900 and 1100 cm −1 (9.09–11.11 μm) is concentrated after the investigation for the largest values of aerosol-affected radiance differences. BTDs in IASI spectral region between 645 and 1200 cm −1 occupies the largest oscillation and the major part of the whole spectrum. The IASI highest window peak-points channels (such as 9.4 and 10.2 μm) are obtained finally, which are the most sensitive ones to the simulated IASI radiance. -- Highlights: ► Sensitive study of aerosol effect on simulated IASI spectral radiance is performed. ► The aerosol components have influenced IASI spectral regions

  20. Mirrored continuum and molecular scale simulations of the ignition of gamma phase RDX

    Stewart, D. Scott; Chaudhuri, Santanu; Joshi, Kaushik; Lee, Kibaek

    2017-01-01

    We describe the ignition of an explosive crystal of gamma-phase RDX due to a thermal hot spot with reactive molecular dynamics (RMD), with first-principles trained, reactive force field based molecular potentials that represents an extremely complex reaction network. The RMD simulation is analyzed by sorting molecular product fragments into high and low molecular weight groups, to represent identifiable components that can be interpreted by a continuum model. A continuum model based on a Gibbs formulation has a single temperature and stress state for the mixture. The continuum simulation that mirrors the atomistic simulation allows us to study the atomistic simulation in the familiar physical chemistry framework and provides an essential, continuum/atomistic link.

  1. Studies of the Pro12Ala polymorphism of the peroxisome proliferator-activated receptor-gamma2 (PPAR-gamma2) gene in relation to insulin sensitivity among glucose tolerant caucasians

    Ek, J; Andersen, G; Urhammer, S A

    2001-01-01

    We examined whether the Pro12-Ala polymorphism of the human peroxisome proliferator-activated receptor-gamma2 (PPAR-gamma2) gene was related to altered insulin sensitivity among glucose-tolerant subjects or a lower accumulated incidence or prevalence of IGT and Type II (non-insulin-dependent) dia......-insulin-dependent) diabetes mellitus among Scandinavian Caucasians....

  2. Characterization and evaluation of three groups of rice upland of different origins through gamma-ray sensitivity

    Rodrigues, Luis Roberto Franco

    2002-01-01

    The characterization and evaluation of varieties of rice aid in the parents selection and in the increase of the genetic base of breeding programs. The present work was carried out to characterize and to evaluate three groups of rice upland (Oryza sativa L.) of different origins through gamma-ray sensitivity. Seeds of 84 varieties collected from Japan, Philippines and Brazil, were submitted to various doses of gamma-radiation and sown in wooden boxes. The experiment was conducted in 1991 at greenhouse according to randomized complete block design with three replications. Physiological effects caused by radiation in the M 1 generation, such as seed emergency, seedling height and survival rate, were determined and evaluated. The results showed significant differences of sensitivity to the radiation among three groups for all traits evaluated. (author)

  3. An overview of the design and analysis of simulation experiments for sensitivity analysis

    Kleijnen, J.P.C.

    2005-01-01

    Sensitivity analysis may serve validation, optimization, and risk analysis of simulation models. This review surveys 'classic' and 'modern' designs for experiments with simulation models. Classic designs were developed for real, non-simulated systems in agriculture, engineering, etc. These designs

  4. Monte Carlo Simulations of Ultra-High Energy Resolution Gamma Detectors for Nuclear Safeguards

    Robles, A.; Drury, O.B.; Friedrich, S.

    2009-01-01

    Ultra-high energy resolution superconducting gamma-ray detectors can improve the accuracy of non-destructive analysis for unknown radioactive materials. These detectors offer an order of magnitude improvement in resolution over conventional high purity germanium detectors. The increase in resolution reduces errors from line overlap and allows for the identification of weaker gamma-rays by increasing the magnitude of the peaks above the background. In order to optimize the detector geometry and to understand the spectral response function Geant4, a Monte Carlo simulation package coded in C++, was used to model the detectors. Using a 1 mm 3 Sn absorber and a monochromatic gamma source, different absorber geometries were tested. The simulation was expanded to include the Cu block behind the absorber and four layers of shielding required for detector operation at 0.1 K. The energy spectrum was modeled for an Am-241 and a Cs-137 source, including scattering events in the shielding, and the results were compared to experimental data. For both sources the main spectral features such as the photopeak, the Compton continuum, the escape x-rays and the backscatter peak were identified. Finally, the low energy response of a Pu-239 source was modeled to assess the feasibility of Pu-239 detection in spent fuel. This modeling of superconducting detectors can serve as a guide to optimize the configuration in future spectrometer designs.

  5. Sensitization of Micrococcus radiophilus to gamma-rays by postirradiation incubation with chloramphenicol or at nonpermissive temperature

    Kitayama, S; Harsojo,; Matsuyama, A [Institute of Physical and Chemical Research, Wako, Saitama (Japan)

    1980-12-01

    M. radiophilus was sensitized to gamma-rays by postirradiation incubation at 42/sup 0/C or at 30/sup 0/C in the presence of chloramphenicol. Radiation induced strand scissions and alkali labile bonds in DNA were repaired by post-irradiation incubation under normal conditions. However, these lesions were repaired only partially during the incubation at 42/sup 0/C or in the presence of chloramphenicol.

  6. Gamma irradiation of cultural artifacts for disinfection using Monte Carlo simulations

    Choi, Jong-il; Yoon, Minchul; Kim, Dongho

    2012-01-01

    In this study, it has been investigated the disinfection of Korean cultural artifacts by gamma irradiation, simulating the absorbed dose distribution on the object with the Monte Carlo methodology. Fungal contamination was identified on two traditional Korean agricultural tools, Hongdukkae and Holtae, which had been stored in a museum. Nine primary species were identified from these items: Bjerkandera adusta, Dothideomycetes sp., Penicillium sp., Cladosporium tenuissimum, Aspergillus versicolor, Penicillium sp., Entrophospora sp., Aspergillus sydowii, and Corynascus sepedonium. However, these fungi were completely inactivated by gamma irradiation at an absorbed dose of 20 kGy on the front side. Monte Carlo N Particle Transport Code was used to simulate the doses applied to these cultural artifacts, and the measured dose distributions were well predicted by the simulations. These results show that irradiation is effective for the disinfection of cultural artifacts and that dose distribution can be predicted with Monte Carlo simulations, allowing the optimization of the radiation treatment. - Highlights: ► Radiation was applied for the disinfection of Korean cultural artifacts. ► Fungi on the artifacts were completely inactivated by the irradiation. ► Monte Carlo N Particle Transport Code was used to predict the dose distribution. ► This study is applicable for the preservation of cultural artifacts by irradiation.

  7. Deterministic sensitivity analysis for the numerical simulation of contaminants transport

    Marchand, E.

    2007-12-01

    The questions of safety and uncertainty are central to feasibility studies for an underground nuclear waste storage site, in particular the evaluation of uncertainties about safety indicators which are due to uncertainties concerning properties of the subsoil or of the contaminants. The global approach through probabilistic Monte Carlo methods gives good results, but it requires a large number of simulations. The deterministic method investigated here is complementary. Based on the Singular Value Decomposition of the derivative of the model, it gives only local information, but it is much less demanding in computing time. The flow model follows Darcy's law and the transport of radionuclides around the storage site follows a linear convection-diffusion equation. Manual and automatic differentiation are compared for these models using direct and adjoint modes. A comparative study of both probabilistic and deterministic approaches for the sensitivity analysis of fluxes of contaminants through outlet channels with respect to variations of input parameters is carried out with realistic data provided by ANDRA. Generic tools for sensitivity analysis and code coupling are developed in the Caml language. The user of these generic platforms has only to provide the specific part of the application in any language of his choice. We also present a study about two-phase air/water partially saturated flows in hydrogeology concerning the limitations of the Richards approximation and of the global pressure formulation used in petroleum engineering. (author)

  8. Simulation study on unfolding methods for diagnostic X-rays and mixed gamma rays

    Hashimoto, Makoto; Ohtaka, Masahiko; Ara, Kuniaki; Kanno, Ikuo; Imamura, Ryo; Mikami, Kenta; Nomiya, Seiichiro; Onabe, Hideaki

    2009-01-01

    A photon detector operating in current mode that can sense X-ray energy distribution has been reported. This detector consists of a row of several segment detectors. The energy distribution is derived using an unfolding technique. In this paper, comparisons of the unfolding techniques among error reduction, spectrum surveillance, and neural network methods are discussed through simulation studies on the detection of diagnostic X-rays and gamma rays emitted by a mixture of 137 Cs and 60 Co. For diagnostic X-ray measurement, the spectrum surveillance and neural network methods appeared promising, while the error reduction method yielded poor results. However, in the case of measuring mixtures of gamma rays, the error reduction method was both sufficient and effective. (author)

  9. MONTE CARLO RADIATION TRANSFER SIMULATIONS OF PHOTOSPHERIC EMISSION IN LONG-DURATION GAMMA-RAY BURSTS

    Lazzati, Davide [Department of Physics, Oregon State University, 301 Weniger Hall, Corvallis, OR 97331 (United States)

    2016-10-01

    We present MCRaT, a Monte Carlo Radiation Transfer code for self-consistently computing the light curves and spectra of the photospheric emission from relativistic, unmagnetized jets. We apply MCRaT to a relativistic hydrodynamic simulation of a long-duration gamma-ray burst jet, and present the resulting light curves and time-dependent spectra for observers at various angles from the jet axis. We compare our results to observational results and find that photospheric emission is a viable model to explain the prompt phase of long-duration gamma-ray bursts at the peak frequency and above, but faces challenges when reproducing the flat spectrum below the peak frequency. We finally discuss possible limitations of these results both in terms of the hydrodynamics and the radiation transfer and how these limitations could affect the conclusions that we present.

  10. Inactivation by gamma irradiation of animal viruses in simulated laboratory effluent

    Thomas, F.C.; Ouwerkerk, T.; McKercher, P.

    1982-01-01

    Several animal viruses were treated with gamma radiation from a 60 Co source under conditions which might be found in effluent from an animal disease laboratory. Swine vesicular disease virus, vesicular stomatitis virus, and blue-tongue virus were irradiated in tissues from experimentally infected animals. Pseudorabies virus, fowl plague virus, swine vesicular disease virus, and vesicular stomatitis virus were irradiated in liquid animal feces. All were tested in animals and in vitro. The D 10 values, that is, the doses required to reduce infectivity by 1 log 10 , were not apparently different from those expected from predictions based on other data and theoretical considerations. The existence of the viruses in pieces of tissues or in liquid feces made no differences in the efficacy of the gamma radiation for inactivating them. Under the ''worst case'' conditions (most protective for virus) simulated in this study, no infectious agents would survive 4.0 Mrads

  11. Guideline of Monte Carlo calculation. Neutron/gamma ray transport simulation by Monte Carlo method

    2002-01-01

    This report condenses basic theories and advanced applications of neutron/gamma ray transport calculations in many fields of nuclear energy research. Chapters 1 through 5 treat historical progress of Monte Carlo methods, general issues of variance reduction technique, cross section libraries used in continuous energy Monte Carlo codes. In chapter 6, the following issues are discussed: fusion benchmark experiments, design of ITER, experiment analyses of fast critical assembly, core analyses of JMTR, simulation of pulsed neutron experiment, core analyses of HTTR, duct streaming calculations, bulk shielding calculations, neutron/gamma ray transport calculations of the Hiroshima atomic bomb. Chapters 8 and 9 treat function enhancements of MCNP and MVP codes, and a parallel processing of Monte Carlo calculation, respectively. An important references are attached at the end of this report.

  12. Analysis of MCNP simulated gamma spectra of CdTe detectors for boron neutron capture therapy.

    Winkler, Alexander; Koivunoro, Hanna; Savolainen, Sauli

    2017-06-01

    The next step in the boron neutron capture therapy (BNCT) is the real time imaging of the boron concentration in healthy and tumor tissue. Monte Carlo simulations are employed to predict the detector response required to realize single-photon emission computed tomography in BNCT, but have failed to correctly resemble measured data for cadmium telluride detectors. In this study we have tested the gamma production cross-section data tables of commonly used libraries in the Monte Carlo code MCNP in comparison to measurements. The cross section data table TENDL-2008-ACE is reproducing measured data best, whilst the commonly used ENDL92 and other studied libraries do not include correct tables for the gamma production from the cadmium neutron capture reaction that is occurring inside the detector. Furthermore, we have discussed the size of the annihilation peaks of spectra obtained by cadmium telluride and germanium detectors. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Familial study of ataxia telangiectasia. Heterozygotes identification on the basis of sensitivity of gamma-irradiated cultures to caffeine post-treatment

    Pawlak, A.L.; Kotecki, M. [Polska Akademia Nauk, Poznan (Poland). Zaklad Genetyki Czlowieka; Ignatowicz, R. [Centrum Zdrowia Dziecka, Warsaw (Poland)

    1994-12-31

    The effects of caffeine (CF), {gamma}-irradiation + CF post-treatment on chromosomal aberrations were studied in lymphocyte cultures from a patient with ataxia telangiectasia (AT), his parents and brother. In the studied family both the homozygotes and the obligatory heterozygotes of AT showed increased sensitivity to CF post-treatment. Individual differences in sensitivity to {gamma}-irradiation + CF post-treatment proved to be correlated with the sensitivity of non-irradiated cells to CF treatment, but not to {gamma}-irradiation. (author). 19 refs, 1 fig., 1 tab.

  14. Simulation-based evaluation and optimization of a new CdZnTe gamma-camera architecture (HiSens)

    Robert, Charlotte; Montemont, Guillaume; Rebuffel, Veronique; Guerin, Lucie; Verger, Loick; Buvat, Irene

    2010-01-01

    A new gamma-camera architecture named HiSens is presented and evaluated. It consists of a parallel hole collimator, a pixelated CdZnTe (CZT) detector associated with specific electronics for 3D localization and dedicated reconstruction algorithms. To gain in efficiency, a high aperture collimator is used. The spatial resolution is preserved thanks to accurate 3D localization of the interactions inside the detector based on a fine sampling of the CZT detector and on the depth of interaction information. The performance of this architecture is characterized using Monte Carlo simulations in both planar and tomographic modes. Detective quantum efficiency (DQE) computations are then used to optimize the collimator aperture. In planar mode, the simulations show that the fine CZT detector pixelization increases the system sensitivity by 2 compared to a standard Anger camera without loss in spatial resolution. These results are then validated against experimental data. In SPECT, Monte Carlo simulations confirm the merits of the HiSens architecture observed in planar imaging.

  15. Effects of the moisture of gamma irradiated tomato-seeds on the plant growth sensitivity

    Kumala Dewi.

    1977-01-01

    The investigation of 2 Krad gamma irradiated dry seeds fruit and tomato seedlings has been carried out. The effect was observed on the time of flowering and fruit bearing, fruits number, fruits weight and time of harvesting. (author)

  16. High-sensitivity multidimensional gamma-ray spectrometer, PRIPYAT` for low-level measurements

    Andrukhovich, S K [and others

    1996-12-31

    The design of the gamma spectrometer PRIPYAT` intended for gamma spectra measurement in the energy range 0.2-3 MeV is discussed. The spectrometer may be used for the food and water control as well as for massive control of environmental contamination. Its background at Cs{sup 134} + Cs{sup 137} measurement regime is less then 9 c/s. 1 fig.

  17. Sensitivity of the green algae Chlamydomonas reinhardtii to gamma radiation: Photosynthetic performance and ROS formation

    Gomes, Tânia, E-mail: tania.gomes@niva.no [Norwegian Institute for Water Research (NIVA), Section of Ecotoxicology and Risk Assessment, Gaustadalléen 21, N-0349, Oslo (Norway); Centre for Environmental Radioactivity, Norwegian University of Life Sciences (NMBU), Post Box 5003, N-1432 Ås (Norway); Xie, Li [Norwegian Institute for Water Research (NIVA), Section of Ecotoxicology and Risk Assessment, Gaustadalléen 21, N-0349, Oslo (Norway); Centre for Environmental Radioactivity, Norwegian University of Life Sciences (NMBU), Post Box 5003, N-1432 Ås (Norway); Brede, Dag; Lind, Ole-Christian [Centre for Environmental Radioactivity, Norwegian University of Life Sciences (NMBU), Post Box 5003, N-1432 Ås (Norway); Department for Environmental Sciences, Faculty of Environmental Science & Technology, Norwegian University of Life Sciences (NMBU), Post Box 5003, N-1432, Ås (Norway); Solhaug, Knut Asbjørn [Centre for Environmental Radioactivity, Norwegian University of Life Sciences (NMBU), Post Box 5003, N-1432 Ås (Norway); Department of Ecology and Natural Resource Management, Norwegian University of Life Sciences (NMBU), Postbox 5003, N-1432, Ås (Norway); Salbu, Brit [Centre for Environmental Radioactivity, Norwegian University of Life Sciences (NMBU), Post Box 5003, N-1432 Ås (Norway); Department for Environmental Sciences, Faculty of Environmental Science & Technology, Norwegian University of Life Sciences (NMBU), Post Box 5003, N-1432, Ås (Norway); and others

    2017-02-15

    Highlights: • Chlorophyll fluorescence parameters affected at higher dose rates. • Changes in PSII associated with electron transport and energy dissipation pathways. • Dose-dependent ROS production in algae exposed to gamma radiation. • Decrease in photosynthetic efficiency connected to ROS formation. - Abstract: The aquatic environment is continuously exposed to ionizing radiation from both natural and anthropogenic sources, making the characterization of ecological and health risks associated with radiation of large importance. Microalgae represent the main source of biomass production in the aquatic ecosystem, thus becoming a highly relevant biological model to assess the impacts of gamma radiation. However, little information is available on the effects of gamma radiation on microalgal species, making environmental radioprotection of this group of species challenging. In this context, the present study aimed to improve the understanding of the effects and toxic mechanisms of gamma radiation in the unicellular green algae Chlamydomonas reinhardtii focusing on the activity of the photosynthetic apparatus and ROS formation. Algal cells were exposed to gamma radiation (0.49–1677 mGy/h) for 6 h and chlorophyll fluorescence parameters obtained by PAM fluorometry, while two fluorescent probes carboxy-H{sub 2}DFFDA and DHR 123 were used for the quantification of ROS. The alterations seen in functional parameters of C. reinhardtii PSII after 6 h of exposure to gamma radiation showed modifications of PSII energy transfer associated with electron transport and energy dissipation pathways, especially at the higher dose rates used. Results also showed that gamma radiation induced ROS in a dose-dependent manner under both light and dark conditions. The observed decrease in photosynthetic efficiency seems to be connected to the formation of ROS and can potentially lead to oxidative stress and cellular damage in chloroplasts. To our knowledge, this is the first

  18. Sensitivity of the green algae Chlamydomonas reinhardtii to gamma radiation: Photosynthetic performance and ROS formation

    Gomes, Tânia; Xie, Li; Brede, Dag; Lind, Ole-Christian; Solhaug, Knut Asbjørn; Salbu, Brit

    2017-01-01

    Highlights: • Chlorophyll fluorescence parameters affected at higher dose rates. • Changes in PSII associated with electron transport and energy dissipation pathways. • Dose-dependent ROS production in algae exposed to gamma radiation. • Decrease in photosynthetic efficiency connected to ROS formation. - Abstract: The aquatic environment is continuously exposed to ionizing radiation from both natural and anthropogenic sources, making the characterization of ecological and health risks associated with radiation of large importance. Microalgae represent the main source of biomass production in the aquatic ecosystem, thus becoming a highly relevant biological model to assess the impacts of gamma radiation. However, little information is available on the effects of gamma radiation on microalgal species, making environmental radioprotection of this group of species challenging. In this context, the present study aimed to improve the understanding of the effects and toxic mechanisms of gamma radiation in the unicellular green algae Chlamydomonas reinhardtii focusing on the activity of the photosynthetic apparatus and ROS formation. Algal cells were exposed to gamma radiation (0.49–1677 mGy/h) for 6 h and chlorophyll fluorescence parameters obtained by PAM fluorometry, while two fluorescent probes carboxy-H 2 DFFDA and DHR 123 were used for the quantification of ROS. The alterations seen in functional parameters of C. reinhardtii PSII after 6 h of exposure to gamma radiation showed modifications of PSII energy transfer associated with electron transport and energy dissipation pathways, especially at the higher dose rates used. Results also showed that gamma radiation induced ROS in a dose-dependent manner under both light and dark conditions. The observed decrease in photosynthetic efficiency seems to be connected to the formation of ROS and can potentially lead to oxidative stress and cellular damage in chloroplasts. To our knowledge, this is the first report

  19. Numerical Simulations of Pillar Structured Solid State Thermal Neutron Detector Efficiency and Gamma Discrimination

    Conway, A; Wang, T; Deo, N; Cheung, C; Nikolic, R

    2008-06-24

    This work reports numerical simulations of a novel three-dimensionally integrated, {sup 10}boron ({sup 10}B) and silicon p+, intrinsic, n+ (PIN) diode micropillar array for thermal neutron detection. The inter-digitated device structure has a high probability of interaction between the Si PIN pillars and the charged particles (alpha and {sup 7}Li) created from the neutron - {sup 10}B reaction. In this work, the effect of both the 3-D geometry (including pillar diameter, separation and height) and energy loss mechanisms are investigated via simulations to predict the neutron detection efficiency and gamma discrimination of this structure. The simulation results are demonstrated to compare well with the measurement results. This indicates that upon scaling the pillar height, a high efficiency thermal neutron detector is possible.

  20. Verification of Gamma-ray Sensitivity for BF3 Neutron Detection System

    Choi, Yu Sun; Cho, Jin Bok; Lyou, Seok Jean

    2016-01-01

    The BF3(Boron Tri-Fluorides) gas filled neutron detector(hereafter BF3 Detector) is commonly used for nuclear reactor’s startup channel due to its relatively high neutron efficiency and good discrimination against gamma-ray backgrounds. In order to measure how much this gamma-ray will affect on BF3 neutron detector performance in view of gamma noise discrimination, Multi-Channel Analyzer(MCA) is utilized for spectrum based signal analysis. The pre-test of BF3 Detector should be performed in an area where the ionization does not exceed 2.5 micro Gy/Hr(Ref.1). In this paper, the discrimination level (Voltage Unit) is verified by experimentally measurement if that discrimination level is acceptable within the criteria or not before installation. The maximum discrimination level, so called LLD, is determined by experimentally measurement. This BF3 Detector (LND20372) is insensitive under 540 micro Gy/Hr of gamma ray and 0.3V of LLD could cut off a background and gamma induced signal in a laboratory. MCA could be a convenient tool for spectrum analysis of signals that induced from gamma ray and a time saving tool rather than oscilloscope investigation due to its function to integrate all input signals at a sudden duration

  1. Simulating Terrestrial Gamma Ray Flashes due to cosmic ray shower electrons and positrons

    Connell, Paul

    2017-04-01

    The University of Valencia has developed a software simulator LEPTRACK to simulate the relativistic runaway electron avalanches, RREA, that are presumed to be the cause of Terrestrial Gamma Ray Flashes and their powerful accompanying Ionization/Excitation Flashes. We show here results of LEPTRACK simulations of RREA by the interaction of MeV energy electrons/positrons and photons in cosmic ray showers traversing plausible electric field geometries expected in storm clouds. The input beams of MeV shower products were created using the CORSIKA software package from the Karlsruhe Institute of Technology. We present images, videos and plots showing the different Ionization, Excitation and gamma-ray photon density fields produced, along with their time and spatial profile evolution, which depend critically on where the line of shower particles intercept the electric field geometry. We also show a new effect of incoming positrons in the shower, which make up a significant fraction of shower products, in particular their apparent "orbiting" within a high altitude negative induced shielding charge layer, which has been conjectured to produce a signature microwave emission, as well as a short range 511 keV annihilation line. The interesting question posed is if this conjectured positron emission can be observed and correlated with TGF orbital observations to show if a TGF originates in the macro E-fields of storm clouds or the micro E-fields of lightning leaders where this positron "orbiting" is not likely to occur.

  2. The simulation of an imaging gamma-ray Compton backscattering device using GEANT4

    Flechas, D.; Cristancho, F.; Sarmiento, L.G.; Fajardo, E.

    2014-01-01

    A gamma-backscattering imaging device dubbed Compton Camera, developed at GSI (Darmstadt, Germany) and modified and studied at the Nuclear Physics Group of the National University of Colombia in Bogota, uses the back-to-back emission of two gamma rays in the positron annihilation to construct a bidimensional image that represents the distribution of matter in the field-of-view of the camera. This imaging capability can be used in a host of different situations, for example, to identify and study deposition and structural defects, and to help locating concealed objects, to name just two cases. In order to increase the understanding of the response of the Compton Camera and, in particular, its image formation process, and to assist in the data analysis, a simulation of the camera was developed using the GEANT4 simulation toolkit. In this work, the images resulting from different experimental conditions are shown. The simulated images and their comparison with the experimental ones already suggest methods to improve the present experimental device. (author)

  3. Characteristics of Multihole Collimator Gamma Camera Simulation Modeled Using MCNP5

    Saripan, M. I.; Mashohor, S.; Adnan, W. A. Wan; Marhaban, M. H.; Hashim, S.

    2008-01-01

    This paper describes the characteristics of the multihole collimator gamma camera that is simulated using the combination of the Monte Carlo N-Particles Code (MCNP) version 5 and in-house software. The model is constructed based on the GCA-7100A Toshiba Gamma Camera at the Royal Surrey County Hospital, Guildford, Surrey, UK. The characteristics are analyzed based on the spatial resolution of the images detected by the Sodium Iodide (NaI) detector. The result is recorded in a list-mode file referred to as a PTRAC file within MCNP5. All pertinent nuclear reaction mechanisms, such as Compton and Rayleigh scattering and photoelectric absorption are undertaken by MCNP5 for all materials encountered by each photon. The experiments were conducted on Tl-201, Co-57, Tc-99 m and Cr-51 radio nuclides. The comparison of full width half maximum value of each datasets obtained from experimental work, simulation and literature are also reported in this paper. The relationship of the simulated data is in agreement with the experimental results and data obtained in the literature. A careful inspection at each of the data points of the spatial resolution of Tc-99 m shows a slight discrepancy between these sets. However, the difference is very insignificant, i.e. less than 3 mm only, which corresponds to a size of less than 1 pixel only (of the segmented detector)

  4. Sensitivity of the green algae Chlamydomonas reinhardtii to gamma radiation: Photosynthetic performance and ROS formation.

    Gomes, Tânia; Xie, Li; Brede, Dag; Lind, Ole-Christian; Solhaug, Knut Asbjørn; Salbu, Brit; Tollefsen, Knut Erik

    2017-02-01

    The aquatic environment is continuously exposed to ionizing radiation from both natural and anthropogenic sources, making the characterization of ecological and health risks associated with radiation of large importance. Microalgae represent the main source of biomass production in the aquatic ecosystem, thus becoming a highly relevant biological model to assess the impacts of gamma radiation. However, little information is available on the effects of gamma radiation on microalgal species, making environmental radioprotection of this group of species challenging. In this context, the present study aimed to improve the understanding of the effects and toxic mechanisms of gamma radiation in the unicellular green algae Chlamydomonas reinhardtii focusing on the activity of the photosynthetic apparatus and ROS formation. Algal cells were exposed to gamma radiation (0.49-1677mGy/h) for 6h and chlorophyll fluorescence parameters obtained by PAM fluorometry, while two fluorescent probes carboxy-H 2 DFFDA and DHR 123 were used for the quantification of ROS. The alterations seen in functional parameters of C. reinhardtii PSII after 6h of exposure to gamma radiation showed modifications of PSII energy transfer associated with electron transport and energy dissipation pathways, especially at the higher dose rates used. Results also showed that gamma radiation induced ROS in a dose-dependent manner under both light and dark conditions. The observed decrease in photosynthetic efficiency seems to be connected to the formation of ROS and can potentially lead to oxidative stress and cellular damage in chloroplasts. To our knowledge, this is the first report on changes in several chlorophyll fluorescence parameters associated with photosynthetic performance and ROS formation in microalgae after exposure to gamma radiation. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Response sensitivity of barrel neuron subpopulations to simulated thalamic input.

    Pesavento, Michael J; Rittenhouse, Cynthia D; Pinto, David J

    2010-06-01

    Our goal is to examine the relationship between neuron- and network-level processing in the context of a well-studied cortical function, the processing of thalamic input by whisker-barrel circuits in rodent neocortex. Here we focus on neuron-level processing and investigate the responses of excitatory and inhibitory barrel neurons to simulated thalamic inputs applied using the dynamic clamp method in brain slices. Simulated inputs are modeled after real thalamic inputs recorded in vivo in response to brief whisker deflections. Our results suggest that inhibitory neurons require more input to reach firing threshold, but then fire earlier, with less variability, and respond to a broader range of inputs than do excitatory neurons. Differences in the responses of barrel neuron subtypes depend on their intrinsic membrane properties. Neurons with a low input resistance require more input to reach threshold but then fire earlier than neurons with a higher input resistance, regardless of the neuron's classification. Our results also suggest that the response properties of excitatory versus inhibitory barrel neurons are consistent with the response sensitivities of the ensemble barrel network. The short response latency of inhibitory neurons may serve to suppress ensemble barrel responses to asynchronous thalamic input. Correspondingly, whereas neurons acting as part of the barrel circuit in vivo are highly selective for temporally correlated thalamic input, excitatory barrel neurons acting alone in vitro are less so. These data suggest that network-level processing of thalamic input in barrel cortex depends on neuron-level processing of the same input by excitatory and inhibitory barrel neurons.

  6. Investigation of some parameters influencing the sensitivity of human tooth enamel to gamma radiation using electron paramagnetic resonance

    El-Faramawy, N.

    2008-01-01

    Electron paramagnetic resonance (EPR) has been successfully used as a physical technique for gamma radiation dose reconstruction using calcified tissues. To minimize potential discrepancies between EPR readings in future studies, the effects of cavity response factor, tooth position and donor gender on the estimated gamma radiation dose were studied. It was found that the EPR response per sample mass used for assessment of doses in teeth outside of the 70-100 mg range should be corrected by a factor which is a function of the sample mass. In the EPR measurements, the difference in sensitivity of different tooth positions to γ-radiation was taken into consideration. It was determined that among all the premolars and molars tooth positions, the relative standard deviation of sensitivity was 6.5%, with the wisdom teeth and the first molars having the highest and lowest sensitivity to γ-radiation, respectively. The current results reveal no effect of the donor gender on the sensitivity to γ-radiation. (author)

  7. Gamma radiation sensitivity in tomato tree and response of plants proceeding from salinity irradiated seeds

    Colaco, Waldeciro; Bidjeke, Raoul; Fleming, Peter M.

    2000-01-01

    Preliminary experiments were conducted to evaluate the radiosensitivity of tomato {Lycopersicon esculentum L. cultivars IPA-6, IPA-8, and Lycopersicum hirsutum glabratum - } to gamma rays from a 60 Co source, considering future induced mutation studies aiming at the improvement of plant salinity tolerance. Sets of dry seeds were exposed to gamma radiation doses (300 - 600 Gy and 100-400 Gy) and compared to a control without irradiation (0 Gy) under greenhouse conditions. The radiosensitivity was initially evaluated through germination of irradiated dry seeds determined at 13 and 30 days after irradiation and also through seedling survival. Seed germination was delayed by gamma irradiation and especially reduced at higher doses (300- 600 Gy). Survival of tomato plants was decreased with increased dose of radiation and was reduced by < 16% at the 300-600 Gy doses. Growth of plants was enhanced at low doses of gamma rays; higher doses reduced plant size. Gamma irradiation had significant effects on tomato plants generated from dry seed and submitted to different levels of salinity. It is recommended a dose range of 100-200 Gy for mutation breeding purpose using the varieties tested. (author)

  8. Intensification of transesterification via sonication numerical simulation and sensitivity study

    Janajreh, Isam; ElSamad, Tala; Noorul Hussain, Mohammed

    2017-01-01

    Highlights: • 3D numerical simulation of transesterification is accomplished. • A non-isothermal, reactive Navier–stokes was carried out. • Conventional and sonicated process was compared as far as reaction kinetics and yield. • Higher kinetic rates are achieved at lower molar ratios in sonicated process. • It validates feasibility of numerical simulation for transesterification assessment. - Abstract: Transesterification is known as slow reaction that can take over several hours to complete. The process involves two immiscible reactants to produce the biodiesel and the byproduct glycerol. Biodiesel commercialization has always been hindered by the long process times of the transesterification reaction. Catalyzing the process and increasing the agitation rate is the mode of intensifying the process additional to the increase of the molar ratio, temperature, circulation that all penalize the overall process metrics. Finding shorter path by reducing the reaction into a few minutes and ensures high quality biodiesel, in economically viable way is coming along with sonication. This drastic reduction moves the technology from the slow batch process into the high throughput continuous process. In a practical sense this means a huge optimization for the biodiesel production process which opens pathways for faster, voluminous and cheaper production. The mechanism of sonication assisted reaction is explained by the creation of microbubbles which increases the interfacial surface reaction areas and the presence of high localized temperature and turbulence as these microbubbles implode. As a result the reaction kinetics of sonicated transesterification as inferred by several authors is much faster. The aim of this work is to implement the inferred rates in a high fidelity numerical reactive flow simulation model while considering the reactor geometry. It is based on Navier–Stokes equations coupled with energy equation for non-isothermal flow and the transport

  9. Radiation sensitivity of two Ginger varieties (Zingiber officinale Rosc.) to gamma irradiation

    Nwachukwu, E.C.; Ene, L.S.O.; Mbanaso, E.N.A.

    1994-01-01

    The mutability and radiosensitivity of two local ginger varieties in Nigeria ''Tafin Giwa'' (UG 1) and ''Yatsun Biri'' (UG 2) were studied using gamma rays from a 60Co gamma source. There was a high frequency of chlorophyll mutations indicating a high mutability in ginger. GR 50 was obtained at 5.0 and 6.0 Gy in UG1, and UG2, respectively, while LD50 was obtained at 8.75 Gy in both varieties. The dose limitation range for ginger was estimated to be 5.0-9.0 Gy [es

  10. The Monte Carlo simulation of the neutron-induced prompt gamma ray spectroscopy of the CW abandoned by Japan

    Wang Bairong; Yang Zhongping; Zhan Wenzhong

    2003-01-01

    This paper introduced the principle of identifying the chemical weapon abandoned by Japan by neutron-induced prompt gamma ray. Using the MCNP-4C Monte Carlo program, this paper simulated and analyzed the neutron-induced prompt gamma ray spectroscopy of chemical weapon abandoned by Japan, whereby supply important datum and reference for the aftertime deeper research and disposal of Japan-abandoned chemical weapon. (authors)

  11. Use of calibration methodology of gamma cameras for the workers surveillance using a thyroid simulator

    Alfaro, M.; Molina, G.; Vazquez, R.; Garcia, O.

    2010-09-01

    In Mexico there are a significant number of nuclear medicine centers in operation. For what the accidents risk related to the transport and manipulation of open sources used in nuclear medicine can exist. The National Institute of Nuclear Research (ININ) has as objective to establish a simple and feasible methodology for the workers surveillance related with the field of the nuclear medicine. This radiological surveillance can also be applied to the public in the event of a radiological accident. To achieve this it intends to use the available equipment s in the nuclear medicine centers, together with the neck-thyroid simulators elaborated by the ININ to calibrate the gamma cameras. The gamma cameras have among their component elements that conform spectrometric systems like the employees in the evaluation of the internal incorporation for direct measurements, reason why, besides their use for diagnostic for image, they can be calibrated with anthropomorphic simulators and also with punctual sources for the quantification of the radionuclides activity distributed homogeneously in the human body, or located in specific organs. Inside the project IAEA-ARCAL-RLA/9/049-LXXVIII -Procedures harmonization of internal dosimetry- where 9 countries intervened (Argentina, Brazil, Colombia, Cuba, Chile, Mexico, Peru, Uruguay and Spain). It was developed a protocol of cameras gamma calibration for the determination in vivo of radionuclides. The protocol is the base to establish and integrated network in Latin America to attend in response to emergencies, using nuclear medicine centers of public hospitals of the region. The objective is to achieve the appropriate radiological protection of the workers, essential for the sure and acceptable radiation use, the radioactive materials and the nuclear energy. (Author)

  12. Optimization of Gamma Knife treatment planning via guided evolutionary simulated annealing

    Zhang Pengpeng; Dean, David; Metzger, Andrew; Sibata, Claudio

    2001-01-01

    We present a method for generating optimized Gamma Knife trade mark sign (Elekta, Stockholm, Sweden) radiosurgery treatment plans. This semiautomatic method produces a highly conformal shot packing plan for the irradiation of an intracranial tumor. We simulate optimal treatment planning criteria with a probability function that is linked to every voxel in a volumetric (MR or CT) region of interest. This sigmoidal P + parameter models the requirement of conformality (i.e., tumor ablation and normal tissue sparing). After determination of initial radiosurgery treatment parameters, a guided evolutionary simulated annealing (GESA) algorithm is used to find the optimal size, position, and weight for each shot. The three-dimensional GESA algorithm searches the shot parameter space more thoroughly than is possible during manual shot packing and provides one plan that is suitable to the treatment criteria of the attending neurosurgeon and radiation oncologist. The result is a more conformal plan, which also reduces redundancy, and saves treatment administration time

  13. Performance simulation and structure design of Binode CdZnTe gamma-ray detector

    Niu Libo; Li Yulan; Fu Jianqiang; Jiang Hao; Zhang Lan; He Bin; Li Yuanjing

    2014-01-01

    A new electrode structure CdZnTe (Cadmium Zinc Telluride) detector named Binode CdZnTe has been pro- posed in this paper. Together with the softwares of MAXWELL, GEANT4, and ROOT, the charge collection process and its gamma spectrum of the detector have been simulated and the detector structure has been optimized. In order to improve its performance further, Compton scattering effect correction has been used. The simulation results demonstrate that with refined design and Compton scattering effect correction, Binode CdZnTe detectors is capable of achieving 3.92% FWHM at 122 keV, and 1.27% FWHM at 662 keV. Com- pared with other single-polarity (electron-only) detector configurations, Binode CdZnTe detector offers a cost effective and simple structure alternative with comparable energy resolution. (authors)

  14. Gamma irradiator dose mapping: a Monte Carlo simulation and experimental measurements

    Rodrigues, Rogerio R.; Ribeiro, Mariana A.; Grynberg, Suely E.; Ferreira, Andrea V.; Meira-Belo, Luiz Claudio; Sousa, Romulo V.; Sebastiao, Rita de C.O.

    2009-01-01

    Gamma irradiator facilities can be used in a wide range of applications such as biological and chemical researches, food treatment and sterilization of medical devices and products. Dose mapping must be performed in these equipment in order to establish plant operational parameters, as dose uniformity, source utilization efficiency and maximum and minimum dose positions. The isodoses curves are generally measured using dosimeters distributed throughout the device, and this procedure often consume a large amount of dosimeters, irradiation time and manpower. However, a detailed curve doses identification of the irradiation facility can be performed using Monte Carlo simulation, which reduces significantly the monitoring with dosimeters. The present work evaluates the absorbed dose in the CDTN/CNEN Gammacell Irradiation Facility, using the Monte Carlo N-particles (MCNP) code. The Gammacell 220, serial number 39, was produced by Atomic Energy of Canada Limited and was loaded with sources of 60 Co. Dose measurements using TLD and Fricke dosimeters were also performed to validate the calculations. The good agreement of the results shows that Monte Carlo simulations can be used as a predictive tool of irradiation planning for the CDTN/CNEN Gamma Cell Irradiator. (author)

  15. Young gamma-ray pulsar: from modeling the gamma-ray emission to the particle-in-cell simulations of the global magnetosphere

    Brambilla, Gabriele; Kalapotharakos, Constantions; Timokhin, Andrey; Kust Harding, Alice; Kazanas, Demosthenes

    2016-04-01

    Accelerated charged particles flowing in the magnetosphere produce pulsar gamma-ray emission. Pair creation processes produce an electron-positron plasma that populates the magnetosphere, in which the plasma is very close to force-free. However, it is unknown how and where the plasma departs from the ideal force-free condition, which consequently inhibits the understanding of the emission generation. We found that a dissipative magnetosphere outside the light cylinder effectively reproduces many aspects of the young gamma-ray pulsar emission as seen by the Fermi Gamma-ray Space Telescope, and through particle-in-cell simulations (PIC), we started explaining this configuration self-consistently. These findings show that, together, a magnetic field structure close to force-free and the assumption of gamma-ray curvature radiation as the emission mechanism are strongly compatible with the observations. Two main issues from the previously used models that our work addresses are the inability to explain luminosity, spectra, and light curve features at the same time and the inconsistency of the electrodynamics. Moreover, using the PIC simulations, we explore the effects of different pair multiplicities on the magnetosphere configurations and the locations of the accelerating regions. Our work aims for a self-consistent modeling of the magnetosphere, connecting the microphysics of the pair-plasma to the global magnetosphere macroscopic quantities. This direction will lead to a greater understanding of pulsar emission at all wavelengths, as well as to concrete insights into the physics of the magnetosphere.

  16. Emulation of simulations of atmospheric dispersion at Fukushima for Sobol' sensitivity analysis

    Girard, Sylvain; Korsakissok, Irène; Mallet, Vivien

    2015-04-01

    Polyphemus/Polair3D, from which derives IRSN's operational model ldX, was used to simulate the atmospheric dispersion at the Japan scale of radionuclides after the Fukushima disaster. A previous study with the screening method of Morris had shown that - The sensitivities depend a lot on the considered output; - Only a few of the inputs are non-influential on all considered outputs; - Most influential inputs have either non-linear effects or are interacting. These preliminary results called for a more detailed sensitivity analysis, especially regarding the characterization of interactions. The method of Sobol' allows for a precise evaluation of interactions but requires large simulation samples. Gaussian process emulators for each considered outputs were built in order to relieve this computational burden. Globally aggregated outputs proved to be easy to emulate with high accuracy, and associated Sobol' indices are in broad agreement with previous results obtained with the Morris method. More localized outputs, such as temporal averages of gamma dose rates at measurement stations, resulted in lesser emulator performances: tests simulations could not satisfactorily be reproduced by some emulators. These outputs are of special interest because they can be compared to available observations, for instance for calibration purpose. A thorough inspection of prediction residuals hinted that the model response to wind perturbations often behaved in very distinct regimes relatively to some thresholds. Complementing the initial sample with wind perturbations set to the extreme values allowed for sensible improvement of some of the emulators while other remained too unreliable to be used in a sensitivity analysis. Adaptive sampling or regime-wise emulation could be tried to circumvent this issue. Sobol' indices for local outputs revealed interesting patterns, mostly dominated by the winds, with very high interactions. The emulators will be useful for subsequent studies. Indeed

  17. Multisite stochastic simulation of daily precipitation from copula modeling with a gamma marginal distribution

    Lee, Taesam

    2018-05-01

    Multisite stochastic simulations of daily precipitation have been widely employed in hydrologic analyses for climate change assessment and agricultural model inputs. Recently, a copula model with a gamma marginal distribution has become one of the common approaches for simulating precipitation at multiple sites. Here, we tested the correlation structure of the copula modeling. The results indicate that there is a significant underestimation of the correlation in the simulated data compared to the observed data. Therefore, we proposed an indirect method for estimating the cross-correlations when simulating precipitation at multiple stations. We used the full relationship between the correlation of the observed data and the normally transformed data. Although this indirect method offers certain improvements in preserving the cross-correlations between sites in the original domain, the method was not reliable in application. Therefore, we further improved a simulation-based method (SBM) that was developed to model the multisite precipitation occurrence. The SBM preserved well the cross-correlations of the original domain. The SBM method provides around 0.2 better cross-correlation than the direct method and around 0.1 degree better than the indirect method. The three models were applied to the stations in the Nakdong River basin, and the SBM was the best alternative for reproducing the historical cross-correlation. The direct method significantly underestimates the correlations among the observed data, and the indirect method appeared to be unreliable.

  18. The effect of extracellular environment on the sensitivity of two strains of Tetrahymena to gamma rays

    Gebicki, J.M.; Darlington, J.L.; Baumgartner, S.

    1980-01-01

    The radiosensitivity of two strains of Tetrahymena pyriformis to gamma radiation was studied. Irradiation of mass suspensions of Tetrahymena in their normal growth medium confirmed earlier reports of their very high resistance to gamma rays. However this resistance was lowered when the cells were irradiated singly. Using mass and single cell cultures of Tetrahymena, it was shown that the mass cultures were not protected by anoxia from the effects of gamma radiation. However when lysates of Tetrahymena suspensions were added to single cell isolates just before irradiation, the cells were protected. Thus the high resistance of cells in mass culture might lie in the release of protective substances by other cells lysing spontaneously, or as a result of radiation damage. The absence of proteose-peptone-yeast in the growth medium markedly increased the lethality of the gamma rays for both strains. The most likely explanation appeared to lie in the protection of cells from indirect effects of radiation by organic materials in the external medium. The results of the present study emphasise the role of the indirect component of radiation damage in cell death. It is likely that much of this damage occurs in cell membranes. (U.K.)

  19. High Sensitivity Detection of Xe Isotopes Via Beta-Gamma Coincidence Counting

    Bowyer, Ted W.; McIntyre, Justin I.; Reeder, Paul L.

    1999-01-01

    Measurement of xenon fission product isotopes is a key element in the global network being established to monitor the Comprehensive Nuclear-Test-Ban Treaty. Pacific Northwest National Laboratory has developed an automated system for separating Xe from air which includes a beta-gamma counting system for 131mXe, 133mXe, 133Xe, and 135Xe. Betas and conversion electrons are detected in a plastic scintillation cell containing the Xe sample. The counting geometry is nearly 100% for beta and conversion electrons. The resolution in the pulse height spectrum from the plastic scintillator is sufficient to observe distinct peaks for specific conversion electrons. Gamma and X-rays are detected in a NaI(Tl) scintillation detector which surrounds the plastic scintillator sample cell. Two-dimensional pulse height spectra of gamma energy versus beta energy are obtained. Each of the four xenon isotopes has a distinctive signature in the two-dimensional energy array. The details of the counting system, examples of two-dimensional beta-gamma data, and operational experience with this counting system will be described

  20. Sensitivity of Canola Seeds Associated Fungi to Gamma Rays During Storage

    Botros, H.W.

    2011-01-01

    The present study was carried out to investigate the possibility of using the gamma radiation to elongate the storage periods of canola seeds (Brassica naps L.). In this respect, canola seeds were irradiated at doses of 0.5, 1.5, 2.5, 3.5, 5.0 and 7.5 kGy gamma rays and stored at room temperature for periods 0, 3, 6, 9 and 12 months. The isolated fungi from non-irradiated post-harvest canola seeds included different species identified as Aspergillus flavus, A. niger, A. condidus, A. fumigatus, A. ochraceus, A. parasiticus, Fusarium oxysporium, F. moniliforme, Penicillium expansum, P. crysogenum, Alternaria brassicae, A. raphani and Trichoderma spp. It was noticed that the predominant species were A. ochraceus, A. flavus, A. niger and F. oxysporium at percentages 16.18, 14.73, 11.00 and 10.53%, respectively. The effective gamma irradiation on the predominant fungi (the sub-lethal dose) was 3.5 kGy for A. ochraceus and 5.0 kGy for F. oxysporium and F. moniliforme. Increasing the irradiated dose up to 7.5 kGy decreased significantly the growth of most isolated fungi. The data also showed that there was a decrease in the total fungal count in stored seeds under the effect of gamma rays for 12 months storage. Also, mycotoxins at the stored seeds were not detected after 12 months storage

  1. Human gamma interferon production by cytotoxic T lymphocytes sensitized during hepatitis A virus infection

    Maier, K.; Gabriel, P.; Koscielniak, E.; Stierhof, Y.D.; Wiedmann, K.H.; Flehmig, B.; Vallbracht, A.

    1988-01-01

    The production of interferon (IFN) during a chromium-51 release assay with hepatitis A virus (HAV)-infected fibroblasts and autologous peripheral blood lymphocytes from patients with acute HAV infection was studied to determine whether IFN plays a role in immunopathogenesis of hepatitis A infection in humans. Skin fibroblasts of eight patients after acute HAV infection and from two control persons without history of current of past HAV infection were infected with HAV. Peripheral blood lymphocytes were collected at different times after the onset of icterus and tested in a chromium-51 release assay against autologous HAV-infected skin fibroblasts for their cytolytic and IFN-producing activity. The IFN produced during the assay was characterized and found to have the properties of human gamma IFN. Cytotoxicity and gamma IFN release were virus specific. The cell types responsible for both functions were characterized and found to be in the HLA-dependent T8 + lymphocyte subset. Considering that gamma IFN has an antiviral effect on persistent HAV infection in vitro and that it probably accounts for stimulation of HLA class I antigen expression on hepatocytes, these experimental results presented here demonstrate that human gamma IFN produced by HAV-specific T cells may participate in pathogenesis of hepatitis A infection in humans

  2. Pharmacological evidences for DFK167-sensitive presenilin-independent gamma-secretase-like activity.

    Sevalle, Jean; Ayral, Erwan; Hernandez, Jean-François; Martinez, Jean; Checler, Frédéric

    2009-07-01

    Amyloid-beta (Abeta) peptides production is thought to be a key event in the neurodegenerative process ultimately leading to Alzheimer's disease (AD) pathology. A bulk of studies concur to propose that the C-terminal moiety of Abeta is released from its precursor beta-amyloid precursor protein by a high molecular weight enzymatic complex referred to as gamma-secretase, that is composed of at least, nicastrin (NCT), Aph-1, Pen-2, and presenilins (PS) 1 or 2. They are thought to harbor the gamma-secretase catalytic activity. However, several lines of evidence suggest that additional gamma-secretase-like activities could potentially contribute to Abeta production. By means of a quenched fluorimetric substrate (JMV2660) mimicking the beta-amyloid precursor protein sequence targeted by gamma-secretase, we first show that as expected, this probe allows monitoring of an activity detectable in several cell systems including the neuronal cell line telencephalon specific murine neurons (TSM1). This activity is reduced by DFK167, N-[N-(3,5-difluorophenacetyl)-L-alanyl]-S-phenylglycine t-butyl ester (DAPT), and LY68458, three inhibitors known to functionally interact with PS. Interestingly, JMV2660 but not the unrelated peptide JMV2692, inhibits Abeta production in an in vitrogamma-secretase assay as expected from a putative substrate competitor. This activity is enhanced by PS1 and PS2 mutations known to be responsible for familial forms of AD and reduced by aspartyl mutations inactivating PS or in cells devoid of PS or NCT. However, we clearly establish that residual JMV2660-hydrolysing activity could be recovered in PS- and NCT-deficient fibroblasts and that this activity remained inhibited by DFK167. Overall, our study describes the presence of a proteolytic activity displaying gamma-secretase-like properties but independent of PS and still blocked by DFK167, suggesting that the PS-dependent complex could not be the unique gamma-secretase activity responsible for Abeta

  3. Determination of data correction coefficients and the sensitivities of the KIER air-borne gamma-ray spectrometer survey system

    Koo, J.H.; Cho, D.H.; Park, Y.S.

    1982-01-01

    In air-borne gamma-ray spectrometer survey, the observed data must be corrected for the background, Compton scattering and flight altitude. And the corrected data are usually converted into the radiometric elements equivalents of the ground, using the sensitivities of the survey system. Accordingly, the correction coefficients and the sensitivities are determined as follows for the KIER air-borne survey system. The stripping or Compton scattering coefficients α, β and γ at the ground level were first determined on the basis of the gamma-ray count rates due to the 5 concrete calibration pads of the Soosaek Airbase, together with the radiometric elements concentrations of the core samples taken from the pads. As for the determination of the exponential altitude coefficients anti μ(K), anti μ(U), anti μ(Th) and anti μ(Tc), the count rates observed over the Hongseong Test Strip of about 3 km length were used after they had been corrected for the background and Compton scattering. The background count rates mainly caused by the air-craft as well as cosmic radiations were determined with the data taken over the West Sea near Anmyon Island, Chung-cheongnam-do. And the corrected count rates observed over the Strip, combined with the average radiometric elements concentrations of the Strip, yielded the sensitivities k(K), k(U) and k(Th) at the 400 feet flight altitude. (author)

  4. Identifying populations sensitive to environmental chemicals by simulating toxicokinetic variability.

    Ring, Caroline L; Pearce, Robert G; Setzer, R Woodrow; Wetmore, Barbara A; Wambaugh, John F

    2017-09-01

    The thousands of chemicals present in the environment (USGAO, 2013) must be triaged to identify priority chemicals for human health risk research. Most chemicals have little of the toxicokinetic (TK) data that are necessary for relating exposures to tissue concentrations that are believed to be toxic. Ongoing efforts have collected limited, in vitro TK data for a few hundred chemicals. These data have been combined with biomonitoring data to estimate an approximate margin between potential hazard and exposure. The most "at risk" 95th percentile of adults have been identified from simulated populations that are generated either using standard "average" adult human parameters or very specific cohorts such as Northern Europeans. To better reflect the modern U.S. population, we developed a population simulation using physiologies based on distributions of demographic and anthropometric quantities from the most recent U.S. Centers for Disease Control and Prevention National Health and Nutrition Examination Survey (NHANES) data. This allowed incorporation of inter-individual variability, including variability across relevant demographic subgroups. Variability was analyzed with a Monte Carlo approach that accounted for the correlation structure in physiological parameters. To identify portions of the U.S. population that are more at risk for specific chemicals, physiologic variability was incorporated within an open-source high-throughput (HT) TK modeling framework. We prioritized 50 chemicals based on estimates of both potential hazard and exposure. Potential hazard was estimated from in vitro HT screening assays (i.e., the Tox21 and ToxCast programs). Bioactive in vitro concentrations were extrapolated to doses that produce equivalent concentrations in body tissues using a reverse dosimetry approach in which generic TK models are parameterized with: 1) chemical-specific parameters derived from in vitro measurements and predicted from chemical structure; and 2) with

  5. Sensitivity study on hydraulic well testing inversion using simulated annealing

    Nakao, Shinsuke; Najita, J.; Karasaki, Kenzi

    1997-11-01

    For environmental remediation, management of nuclear waste disposal, or geothermal reservoir engineering, it is very important to evaluate the permeabilities, spacing, and sizes of the subsurface fractures which control ground water flow. Cluster variable aperture (CVA) simulated annealing has been used as an inversion technique to construct fluid flow models of fractured formations based on transient pressure data from hydraulic tests. A two-dimensional fracture network system is represented as a filled regular lattice of fracture elements. The algorithm iteratively changes an aperture of cluster of fracture elements, which are chosen randomly from a list of discrete apertures, to improve the match to observed pressure transients. The size of the clusters is held constant throughout the iterations. Sensitivity studies using simple fracture models with eight wells show that, in general, it is necessary to conduct interference tests using at least three different wells as pumping well in order to reconstruct the fracture network with a transmissivity contrast of one order of magnitude, particularly when the cluster size is not known a priori. Because hydraulic inversion is inherently non-unique, it is important to utilize additional information. The authors investigated the relationship between the scale of heterogeneity and the optimum cluster size (and its shape) to enhance the reliability and convergence of the inversion. It appears that the cluster size corresponding to about 20--40 % of the practical range of the spatial correlation is optimal. Inversion results of the Raymond test site data are also presented and the practical range of spatial correlation is evaluated to be about 5--10 m from the optimal cluster size in the inversion

  6. Sensitivity study on hydraulic well testing inversion using simulated annealing

    Nakao, Shinsuke; Najita, J.; Karasaki, Kenzi

    1997-11-01

    For environmental remediation, management of nuclear waste disposal, or geothermal reservoir engineering, it is very important to evaluate the permeabilities, spacing, and sizes of the subsurface fractures which control ground water flow. Cluster variable aperture (CVA) simulated annealing has been used as an inversion technique to construct fluid flow models of fractured formations based on transient pressure data from hydraulic tests. A two-dimensional fracture network system is represented as a filled regular lattice of fracture elements. The algorithm iteratively changes an aperture of cluster of fracture elements, which are chosen randomly from a list of discrete apertures, to improve the match to observed pressure transients. The size of the clusters is held constant throughout the iterations. Sensitivity studies using simple fracture models with eight wells show that, in general, it is necessary to conduct interference tests using at least three different wells as pumping well in order to reconstruct the fracture network with a transmissivity contrast of one order of magnitude, particularly when the cluster size is not known a priori. Because hydraulic inversion is inherently non-unique, it is important to utilize additional information. The authors investigated the relationship between the scale of heterogeneity and the optimum cluster size (and its shape) to enhance the reliability and convergence of the inversion. It appears that the cluster size corresponding to about 20--40 % of the practical range of the spatial correlation is optimal. Inversion results of the Raymond test site data are also presented and the practical range of spatial correlation is evaluated to be about 5--10 m from the optimal cluster size in the inversion.

  7. Multi-Band Light Curves from Two-Dimensional Simulations of Gamma-Ray Burst Afterglows

    MacFadyen, Andrew

    2010-01-01

    The dynamics of gamma-ray burst outflows is inherently multi-dimensional. 1.) We present high resolution two-dimensional relativistic hydrodynamics simulations of GRBs in the afterglow phase using adaptive mesh refinement (AMR). Using standard synchrotron radiation models, we compute multi-band light curves, from the radio to X-ray, directly from the 2D hydrodynamics simulation data. We will present on-axis light curves for both constant density and wind media. We will also present off-axis light curves relevant for searches for orphan afterglows. We find that jet breaks are smoothed due to both off-axis viewing and wind media effects. 2.) Non-thermal radiation mechanisms in GRB afterglows require substantial magnetic field strengths. In turbulence driven by shear instabilities in relativistic magnetized gas, we demonstrate that magnetic field is naturally amplified to half a percent of the total energy (epsilon B = 0.005). We will show high resolution three dimensional relativistic MHD simulations of this process as well as particle in cell (PIC) simulations of mildly relativistic collisionless shocks.

  8. Studies on gamma ray sensitivity in horsegram (Macrotyloma uniflorum Lam Verdc)

    Anitha, R.; Pradeep, R.; Prasannakumari, M.; Sudhagar, R.

    2017-01-01

    In the present study, it is aimed to generate viable mutants of Paiyur 2 having determinate growth habit, non shattering pods and reduced duration by 7-10 days. The reduced duration would help the variety suited to the area prone for terminal drought. The seed of the variety Paiyur 2 was treated with gamma ray doses ranging from 100 to 600 Gray (Gy). The seeds with 12 per cent moisture content were soaked for six hours in water, drained to the sufficient moisture, and mutated with gamma ray. The gamma chamber facility available in the Centre for Plant Breeding and Genetics, Tamil Nadu Agricultural University (Model 1200) was made use of. One hundred seeds were mutated at each dose. The germination percentage, shoot and root length were documented at 14 days after sowing. Probit analysis was used to fix the LD50 value. The germination percentage varied between 0 to 20 per cent at higher concentrations. The lower germination was attributed to chromosomal abnormalities. From the study, it is determined that 300 Gy is the suitable dose at which maximum mutation occurs that offers scope for further exploitation

  9. Thermoluminescence of simulated interstellar matter after gamma-ray irradiation. Forsterite, enstatite and carbonates

    Koike, K.; Nakagawa, M.; Koike, C.; Okada, M.; Chihara, H.

    2002-08-01

    Interstellar matter is known to be strongly irradiated by cosmic radiation and several types of cosmic ray particles. Simulated interstellar matter, such as synthesized forsterite (Mg2SiO4), enstatite (MgSiO3) and magnesite (MgCO3), has been irradiated with 60Co gamma-rays in liquid nitrogen, and also irradiated with fast neutrons at 10 K and 70 K by making use of the low-temperature irradiation facility of the Kyoto University Reactor (KUR-LTL. Maximum fast neutron dose is 1017nf /cm2). After irradiation, samples are stored in liquid nitrogen for several months to allow the decay of induced radioactivity. We measured the luminescence spectra of the gamma ray irradiated samples during warming to 370 K using a spectrophotometer. For the forsterite and magnesite, the spectra exhibit a rather intense peak at about 645-655 nm and 660 nm respectively, whereas luminescence scarcely appeared in the natural olivine sample. The spectra of forsterite is very similar to the ERE of the Red Rectangle.

  10. Gamma knife simulation using the MCNP4C code and the zubal phantom and comparison with experimental data

    Gholami, S.; Kamali Asl, A.; Aghamiri, M.; Allahverdi, M.

    2010-01-01

    Gamma Knife is an instrument specially designed for treating brain disorders. In Gamma Knife, there are 201 narrow beams of cobalt-60 sources that intersect at an isocenter point to treat brain tumors. The tumor is placed at the isocenter and is treated by the emitted gamma rays. Therefore, there is a high dose at this point and a low dose is delivered to the normal tissue surrounding the tumor. Material and Method: In the current work, the MCNP simulation code was used to simulate the Gamma Knife. The calculated values were compared to the experimental ones and previous works. Dose distribution was compared for different collimators in a water phantom and the Zubal brain-equivalent phantom. The dose profiles were obtained along the x, y and z axes. Result: The evaluation of the developed code was performed using experimental data and we found a good agreement between our simulation and experimental data. Discussion: Our results showed that the skull bone has a high contribution to both scatter and absorbed dose. In other words, inserting the exact material of brain and other organs of the head in digital phantom improves the quality of treatment planning. This work is regarding the measurement of absorbed dose and improving the treatment planning procedure in Gamma-Knife radiosurgery in the brain.

  11. Gamma Knife Simulation Using the MCNP4C Code and the Zubal Phantom and Comparison with Experimental Data

    Somayeh Gholami

    2010-06-01

    Full Text Available Introduction: Gamma Knife is an instrument specially designed for treating brain disorders. In Gamma Knife, there are 201 narrow beams of cobalt-60 sources that intersect at an isocenter point to treat brain tumors. The tumor is placed at the isocenter and is treated by the emitted gamma rays. Therefore, there is a high dose at this point and a low dose is delivered to the normal tissue surrounding the tumor. Material and Method: In the current work, the MCNP simulation code was used to simulate the Gamma Knife. The calculated values were compared to the experimental ones and previous works. Dose distribution was compared for different collimators in a water phantom and the Zubal brain-equivalent phantom. The dose profiles were obtained along the x, y and z axes. Result: The evaluation of the developed code was performed using experimental data and we found a good agreement between our simulation and experimental data. Discussion: Our results showed that the skull bone has a high contribution to both scatter and absorbed dose. In other words, inserting the exact material of brain and other organs of the head in digital phantom improves the quality of treatment planning. This work is regarding the measurement of absorbed dose and improving the treatment planning procedure in Gamma-Knife radiosurgery in the brain.

  12. Dose rate determinations in the Portuguese Gamma Irradiation Facility: Monte Carlo simulations and measurements

    Oliveira, C.; Salgado, J.; Ferro de Carvalho, A.

    2000-01-01

    A simulation study of the Portuguese Gamma Irradiation Facility, UTR, has been carried out using the MCNP code. The work focused on the optimisation of the dose distribution inside the irradiation cell, dose calculations inside irradiated samples and dose calculations in critical points for protection purposes. Calculations were carried out at points inside and outside the irradiation cell, where different behaviour was expected (distance from the source, radiation absorption and scattering in irradiator structure and walls). The contributions from source, irradiator structure, sample material, carriers, walls, ceiling and floor to the photon spectra and air kerma at those points are reported and discussed. Air kerma measurements were also carried out using an ionisation chamber. Good agreement was found between experimental and calculated air kermas. (author)

  13. Using the computer simulation methods for the PHOS gamma spectrometer in the ALICE design. Pt. 1. Simulation of the base module response on a high-energy gamma quantum

    Antonenko, V.G.; Blau, D.S.

    2006-01-01

    After all lead tungstate crystals have been fabricated and transferred for assembling of the gamma-spectrometer PHOS in frame of ALICE experiment on the Large Hadron Collider a simulation was performed of the light collection in single scintillation module taking into account realistic properties of entire crystal party [ru

  14. Sensitivity of Simulated Cyclone Gonu Intensity and Track to Variety ...

    57

    improvement in simulated intensity, an accuracy reduction in simulated track was observed. Increasing ... improve the prediction of the TC Gonu using the Advanced Hurricane WRF (AHW) model. For the first time, ...... World Meteorological Organization (2014) Tropical cyclone operational plan for the Bay of. Bengal and the ...

  15. Using sensitivity derivatives for design and parameter estimation in an atmospheric plasma discharge simulation

    Lange, Kyle J.; Anderson, W. Kyle

    2010-01-01

    The problem of applying sensitivity analysis to a one-dimensional atmospheric radio frequency plasma discharge simulation is considered. A fluid simulation is used to model an atmospheric pressure radio frequency helium discharge with a small nitrogen impurity. Sensitivity derivatives are computed for the peak electron density with respect to physical inputs to the simulation. These derivatives are verified using several different methods to compute sensitivity derivatives. It is then demonstrated how sensitivity derivatives can be used within a design cycle to change these physical inputs so as to increase the peak electron density. It is also shown how sensitivity analysis can be used in conjunction with experimental data to obtain better estimates for rate and transport parameters. Finally, it is described how sensitivity analysis could be used to compute an upper bound on the uncertainty for results from a simulation.

  16. A two-dimensional low energy gamma-ray position sensitive detector

    Charalambous, P.M.; Dean, A.J.; Drane, M.; Gil, A.; Stephen, J.B.; Young, N.G.S.; Barbareschi, L.; Perotti, F.; Villa, G.; Badiali, M.; La Padula, C.; Polcaro, F.; Ubertini, P.

    1984-01-01

    An array of 1-dimensional position sensitive detectors designed to operate over the photon energy range 0.2-10.0 MeV, so as to form an efficient 2-dimensional position sensitive detection plane is described. A series of experimental tests has been carried out to evaluate and confirm the computed capabilities. (orig.)

  17. Sensitivity of tropical cyclone Jal simulations to physics ...

    tial to predict a mesoscale weather system. Previ- ous sensitivity studies ... Forecast System (GFS) real time prediction. In this study, the ... time prediction is akin to running a real time fore- cast. Furthermore ...... Operating system. Red hat Linux.

  18. Global sensitivity analysis in stochastic simulators of uncertain reaction networks

    Navarro, Marí a; Le Maitre, Olivier; Knio, Omar

    2016-01-01

    sources are independent, and considers the Poisson processes in the random-time-change representation of the state dynamics as the fundamental objects governing the inherent stochasticity. A sampling algorithm is proposed to perform the global sensitivity

  19. Vendor Testing of Sensitive Compounds in Simulated Dry Sludge

    Dworjanyn, L.O.

    1999-01-01

    This assessment covers thermal screening, differential scanning calorimetry, and impact sensitivity testing on Mercury Fulminate, and mixtures of the fulminate in dry inorganic sludge, which is present in large quantities in a number of storage tanks at Westinghouse Savannah River

  20. Global sensitivity analysis in stochastic simulators of uncertain reaction networks.

    Navarro Jimenez, M; Le Maître, O P; Knio, O M

    2016-12-28

    Stochastic models of chemical systems are often subjected to uncertainties in kinetic parameters in addition to the inherent random nature of their dynamics. Uncertainty quantification in such systems is generally achieved by means of sensitivity analyses in which one characterizes the variability with the uncertain kinetic parameters of the first statistical moments of model predictions. In this work, we propose an original global sensitivity analysis method where the parametric and inherent variability sources are both treated through Sobol's decomposition of the variance into contributions from arbitrary subset of uncertain parameters and stochastic reaction channels. The conceptual development only assumes that the inherent and parametric sources are independent, and considers the Poisson processes in the random-time-change representation of the state dynamics as the fundamental objects governing the inherent stochasticity. A sampling algorithm is proposed to perform the global sensitivity analysis, and to estimate the partial variances and sensitivity indices characterizing the importance of the various sources of variability and their interactions. The birth-death and Schlögl models are used to illustrate both the implementation of the algorithm and the richness of the proposed analysis method. The output of the proposed sensitivity analysis is also contrasted with a local derivative-based sensitivity analysis method classically used for this type of systems.

  1. Global sensitivity analysis in stochastic simulators of uncertain reaction networks

    Navarro, María

    2016-12-26

    Stochastic models of chemical systems are often subjected to uncertainties in kinetic parameters in addition to the inherent random nature of their dynamics. Uncertainty quantification in such systems is generally achieved by means of sensitivity analyses in which one characterizes the variability with the uncertain kinetic parameters of the first statistical moments of model predictions. In this work, we propose an original global sensitivity analysis method where the parametric and inherent variability sources are both treated through Sobol’s decomposition of the variance into contributions from arbitrary subset of uncertain parameters and stochastic reaction channels. The conceptual development only assumes that the inherent and parametric sources are independent, and considers the Poisson processes in the random-time-change representation of the state dynamics as the fundamental objects governing the inherent stochasticity. A sampling algorithm is proposed to perform the global sensitivity analysis, and to estimate the partial variances and sensitivity indices characterizing the importance of the various sources of variability and their interactions. The birth-death and Schlögl models are used to illustrate both the implementation of the algorithm and the richness of the proposed analysis method. The output of the proposed sensitivity analysis is also contrasted with a local derivative-based sensitivity analysis method classically used for this type of systems.

  2. Coupled multi-group neutron photon transport for the simulation of high-resolution gamma-ray spectroscopy applications

    Burns, Kimberly A. [Georgia Inst. of Technology, Atlanta, GA (United States)

    2009-08-01

    The accurate and efficient simulation of coupled neutron-photon problems is necessary for several important radiation detection applications. Examples include the detection of nuclear threats concealed in cargo containers and prompt gamma neutron activation analysis for nondestructive determination of elemental composition of unknown samples.

  3. UV and gamma-ray sensitivity of meiosis-deficient mutants in Podospora anserina

    Simonet, J.M.

    1976-01-01

    Two mutants, mei1 and mei2, were isolated by screening for deficiencies occurring in the meiotic process. The sensitivity of mei1 and mei2 mutant strains to UV irradiation showed a significant increase as compared with that of the wild-type stock, hwhereas the sensitivity to γ-rays remained unchanged. The double-mutant strains were no more sensitive than each single mutant. The data indicate that both mei1 and mei2 loci are probably involved in the same pathway of excision-repair of UV-induced lesions

  4. Simulating deep surveys of the Galactic Plane with the Advanced Gamma-ray Imaging System (AGIS)

    Funk, Stefan; Digel, Seth

    2009-05-01

    The pioneering survey of the Galactic plane by H.E.S.S., together with the northern complement now underway with VERITAS, has shown the inner Milky Way to be rich in TeV-emitting sources; new source classes have been found among the H.E.S.S. detections and unidentified sources remain. In order to explore optimizations of the design of an Advanced Gamma-ray Imaging System (AGIS)-like instrument for survey science, we constructed a model of the flux and size distributions of Galactic TeV sources, normalized to the H.E.S.S. sources but extrapolated to lower flux levels. We investigated potential outcomes from a survey with the order of magnitude improvement in sensitivity and attendant improvement in angular resolution planned for AGIS. Studies of individual sources and populations found with such a sensitivity survey will advance understanding of astrophysical particle acceleration, source populations, and even high-energy cosmic rays via detection of the low-level TeV diffuse emission in regions of high cosmic-ray densitiy.

  5. An Overview of the Design and Analysis of Simulation Experiments for Sensitivity Analysis

    Kleijnen, J.P.C.

    2004-01-01

    Sensitivity analysis may serve validation, optimization, and risk analysis of simulation models.This review surveys classic and modern designs for experiments with simulation models.Classic designs were developed for real, non-simulated systems in agriculture, engineering, etc.These designs assume a

  6. Quantitative comparison between experimental and simulated gamma-ray spectra induced by 14 MeV tagged neutrons

    Perot, B., E-mail: bertrand.perot@cea.fr [CEA, DEN, Cadarache, Nuclear Measurement Laboratory, F-13108 Saint-Paul-lez-Durance (France); El Kanawati, W.; Carasco, C.; Eleon, C. [CEA, DEN, Cadarache, Nuclear Measurement Laboratory, F-13108 Saint-Paul-lez-Durance (France); Valkovic, V. [A.C.T.d.o.o., Prilesje 4, 10000 Zagreb (Croatia); Sudac, D.; Obhodas, J. [Ruder Boskovic Institute, Bijenicka c. 54, 10000 Zagreb (Croatia); Sannie, G. [CEA, LIST, Saclay, F-91191 Gif-sur-Yvette (France)

    2012-07-15

    Fast neutron interrogation with the associated particle technique can be used to identify explosives in cargo containers (EURITRACK FP6 project) and unexploded ordnance on the seabed (UNCOSS FP7 project), by detecting gamma radiations induced by 14 MeV neutrons produced in the {sup 2}H({sup 3}H,{alpha})n reaction. The origin of the gamma rays can be determined in 3D by the detection of the alpha particle, which provides the direction of the opposite neutron and its time-of-flight. Gamma spectroscopy provides the relative counts of carbon, nitrogen, and oxygen, which are converted to chemical fractions to differentiate explosives from other organic substances. To this aim, Monte Carlo calculations are used to take into account neutron moderation and gamma attenuation in cargo materials or seawater. This paper presents an experimental verification that C, N, and O counts are correctly reproduced by numerical simulation. A quantitative comparison is also reported for silicon, iron, lead, and aluminium. - Highlights: Black-Right-Pointing-Pointer Gamma-ray spectra produced by 14 MeV neutrons in C, N, O, Si, Al, Fe, and Pb elements. Black-Right-Pointing-Pointer Quantitative comparison with MCNPX simulations using the ENDF/B-VII.0 library. Black-Right-Pointing-Pointer C, N, and O counts correctly reproduced and chemical proportions recovered using calculation. Black-Right-Pointing-Pointer Application to the detection of explosives or illicit drugs in cargo containers.

  7. Monte Carlo simulation of mixed neutron-gamma radiation fields and dosimetry devices

    Zhang, Guoqing

    2011-01-01

    Monte Carlo methods based on random sampling are widely used in different fields for the capability of solving problems with a large number of coupled degrees of freedom. In this work, Monte Carlos methods are successfully applied for the simulation of the mixed neutron-gamma field in an interim storage facility and neutron dosimeters of different types. Details are discussed in two parts: In the first part, the method of simulating an interim storage facility loaded with CASTORs is presented. The size of a CASTOR is rather large (several meters) and the CASTOR wall is very thick (tens of centimeters). Obtaining the results of dose rates outside a CASTOR with reasonable errors costs usually hours or even days. For the simulation of a large amount of CASTORs in an interim storage facility, it needs weeks or even months to finish a calculation. Variance reduction techniques were used to reduce the calculation time and to achieve reasonable relative errors. Source clones were applied to avoid unnecessary repeated calculations. In addition, the simulations were performed on a cluster system. With the calculation techniques discussed above, the efficiencies of calculations can be improved evidently. In the second part, the methods of simulating the response of neutron dosimeters are presented. An Alnor albedo dosimeter was modelled in MCNP, and it has been simulated in the facility to calculate the calibration factor to get the evaluated response to a Cf-252 source. The angular response of Makrofol detectors to fast neutrons has also been investigated. As a kind of SSNTD, Makrofol can detect fast neutrons by recording the neutron induced heavy charged recoils. To obtain the information of charged recoils, general-purpose Monte Carlo codes were used for transporting incident neutrons. The response of Makrofol to fast neutrons is dependent on several factors. Based on the parameters which affect the track revealing, the formation of visible tracks was determined. For

  8. Monte Carlo simulation of mixed neutron-gamma radiation fields and dosimetry devices

    Zhang, Guoqing

    2011-12-22

    Monte Carlo methods based on random sampling are widely used in different fields for the capability of solving problems with a large number of coupled degrees of freedom. In this work, Monte Carlos methods are successfully applied for the simulation of the mixed neutron-gamma field in an interim storage facility and neutron dosimeters of different types. Details are discussed in two parts: In the first part, the method of simulating an interim storage facility loaded with CASTORs is presented. The size of a CASTOR is rather large (several meters) and the CASTOR wall is very thick (tens of centimeters). Obtaining the results of dose rates outside a CASTOR with reasonable errors costs usually hours or even days. For the simulation of a large amount of CASTORs in an interim storage facility, it needs weeks or even months to finish a calculation. Variance reduction techniques were used to reduce the calculation time and to achieve reasonable relative errors. Source clones were applied to avoid unnecessary repeated calculations. In addition, the simulations were performed on a cluster system. With the calculation techniques discussed above, the efficiencies of calculations can be improved evidently. In the second part, the methods of simulating the response of neutron dosimeters are presented. An Alnor albedo dosimeter was modelled in MCNP, and it has been simulated in the facility to calculate the calibration factor to get the evaluated response to a Cf-252 source. The angular response of Makrofol detectors to fast neutrons has also been investigated. As a kind of SSNTD, Makrofol can detect fast neutrons by recording the neutron induced heavy charged recoils. To obtain the information of charged recoils, general-purpose Monte Carlo codes were used for transporting incident neutrons. The response of Makrofol to fast neutrons is dependent on several factors. Based on the parameters which affect the track revealing, the formation of visible tracks was determined. For

  9. THREE-DIMENSIONAL SIMULATIONS OF LONG DURATION GAMMA-RAY BURST JETS: TIMESCALES FROM VARIABLE ENGINES

    López-Cámara, D. [CONACYT—Instituto de Astronomía, Universidad Nacional Autónoma de México, Apdo. Postal 70-264, Cd. Universitaria, México DF 04510, México (Mexico); Lazzati, Davide [Department of Physics, Oregon State University, 301 Weniger Hall, Corvallis, OR 97331 (United States); Morsony, Brian J., E-mail: diego@astro.unam.mx [Department of Astronomy, University of Maryland, 4296 Stadium Drive, College Park, MD 20742-2421 (United States)

    2016-08-01

    Gamma-ray burst (GRB) light curves are characterized by marked variability, each showing unique properties. The origin of this variability, at least for a fraction of long GRBs, may be the result of an unsteady central engine. It is thus important to study the effects that an episodic central engine has on the jet propagation and, eventually, on the prompt emission within the collapsar scenario. Thus, in this study we follow the interaction of pulsed outflows with their progenitor stars with hydrodynamic numerical simulations in both two and three dimensions. We show that the propagation of unsteady jets is affected by the interaction with the progenitor material well after the break-out time, especially for jets with long quiescent times comparable to or larger than a second. We also show that this interaction can lead to an asymmetric behavior in which pulse durations and quiescent periods are systematically different. After the pulsed jets drill through the progenitor and the interstellar medium, we find that, on average, the quiescent epochs last longer than the pulses (even in simulations with symmetrical active and quiescent engine times). This could explain the asymmetry detected in the light curves of long quiescent time GRBs.

  10. A sensitive and quantitative biosensing method for the determination of {gamma}-ray emitting radionuclides in surface water

    Wolterbeek, H.Th.; Meer, A.J.G.M. van der [Technische Univ. Delft (Netherlands). Interfacultair Reactor Inst.

    1996-11-01

    A quantitative and sensitive biosensing method has been developed for the determination of {gamma}-ray emitting radionuclides in surface water. The method is based on the concept that at equilibrium the specific radioactivity in the biosensor is equal to the specific radioactivity in water. The method consists of the measurement of both the radionuclide and the element in the biosensor and the determination of the element level in water. This three-way analysis eliminates problems such as unpredictable biosensor behaviour, effects of water elemental composition or further abiotic parameters: what remains is the generally high enrichment (bioaccumulation factor BCF) of elements and radionuclides in the biosensor material. Measurements were performed with floating water plants (Azolla filiculoides Lamk., Spirodela polyrhiza/Lemna sp.) and the fully submerged water plant Ceratophyllum demersum L., which were sampled from ditch water. Concentrations of elements and radionuclides were determined in both water and biosensor plants, using Neutron Activation Analysis (NAA), ICP-MS, and {gamma}-ray spectrometry, respectively. For the latter, both 1 litre samples (Marinelli-geometry) and 1 cm{sup 3} samples (well-type detectors) were applied in measurements. (author).

  11. Simulation-based Investigation of Electric Power Generation by Using Gamma Radiation from Spent Nuclear Fuel

    Lee, Haneol; Yim, Mansung [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2014-05-15

    This study investigates the feasibility of using gamma radiation energy from spent nuclear fuels to produce electricity as emergency power source. The proposed electric power system includes electricity generation and storage. Electricity generation was based on conversion of gamma energy to light energy using a scintillator and then to electric energy using a solar cell. Generated electricity was to be stored in a battery as a power source. The efficiency of energy conversion and the extent of the resulting electric power source capability were examined by computer model-based simulation. Main factors which affect to total electric power generated include thermal power of nuclear power plant, average burn-up period for fuel rod, battery charging time, and scintillator thickness. The estimated total power generation and its possible application is discussed. Although the output power increases as scintillator becomes thicker, thick scintillator can be problem because of its high price. There are two ways to solve this problem. The first one is to use thin scintillator to whole fuel assembly area. The second one is to use thick scintillator to limited region. But the current per fuel assembly for the first case for 4000MWth, 72 month burnup is about several to tens of microampere scale, which is too small to charge. Because of this the system is supposed to have thick scintillator system with limited region. Based on the results, the generated electricity is expected to be insufficient to operate the safety injection pumps even at the maximum power output. This may be important for security purposes. Based on the current design, the solar cell efficiency is estimated to be around 1.5-4%. As the efficiency is a strong function of scintillation wavelength, improving the efficiency may be possible by broadening the wavelength through the use of multiple scintillators. Future work will also include validation of the results through experiments, and material reliability

  12. Simulation-based Investigation of Electric Power Generation by Using Gamma Radiation from Spent Nuclear Fuel

    Lee, Haneol; Yim, Mansung

    2014-01-01

    This study investigates the feasibility of using gamma radiation energy from spent nuclear fuels to produce electricity as emergency power source. The proposed electric power system includes electricity generation and storage. Electricity generation was based on conversion of gamma energy to light energy using a scintillator and then to electric energy using a solar cell. Generated electricity was to be stored in a battery as a power source. The efficiency of energy conversion and the extent of the resulting electric power source capability were examined by computer model-based simulation. Main factors which affect to total electric power generated include thermal power of nuclear power plant, average burn-up period for fuel rod, battery charging time, and scintillator thickness. The estimated total power generation and its possible application is discussed. Although the output power increases as scintillator becomes thicker, thick scintillator can be problem because of its high price. There are two ways to solve this problem. The first one is to use thin scintillator to whole fuel assembly area. The second one is to use thick scintillator to limited region. But the current per fuel assembly for the first case for 4000MWth, 72 month burnup is about several to tens of microampere scale, which is too small to charge. Because of this the system is supposed to have thick scintillator system with limited region. Based on the results, the generated electricity is expected to be insufficient to operate the safety injection pumps even at the maximum power output. This may be important for security purposes. Based on the current design, the solar cell efficiency is estimated to be around 1.5-4%. As the efficiency is a strong function of scintillation wavelength, improving the efficiency may be possible by broadening the wavelength through the use of multiple scintillators. Future work will also include validation of the results through experiments, and material reliability

  13. THREE-DIMENSIONAL ADAPTIVE MESH REFINEMENT SIMULATIONS OF LONG-DURATION GAMMA-RAY BURST JETS INSIDE MASSIVE PROGENITOR STARS

    Lopez-Camara, D.; Lazzati, Davide [Department of Physics, NC State University, 2401 Stinson Drive, Raleigh, NC 27695-8202 (United States); Morsony, Brian J. [Department of Astronomy, University of Wisconsin-Madison, 2535 Sterling Hall, 475 N. Charter Street, Madison, WI 53706-1582 (United States); Begelman, Mitchell C., E-mail: dlopezc@ncsu.edu [JILA, University of Colorado, 440 UCB, Boulder, CO 80309-0440 (United States)

    2013-04-10

    We present the results of special relativistic, adaptive mesh refinement, 3D simulations of gamma-ray burst jets expanding inside a realistic stellar progenitor. Our simulations confirm that relativistic jets can propagate and break out of the progenitor star while remaining relativistic. This result is independent of the resolution, even though the amount of turbulence and variability observed in the simulations is greater at higher resolutions. We find that the propagation of the jet head inside the progenitor star is slightly faster in 3D simulations compared to 2D ones at the same resolution. This behavior seems to be due to the fact that the jet head in 3D simulations can wobble around the jet axis, finding the spot of least resistance to proceed. Most of the average jet properties, such as density, pressure, and Lorentz factor, are only marginally affected by the dimensionality of the simulations and therefore results from 2D simulations can be considered reliable.

  14. Effects of Temperature on Sensitivity of Bacilus licheniformis RI 75-1 Vegetative Cells at Gamma Quantum

    Fernandez-Larrea Vega, O.; Rios Brito, F.; Marquez Alvarez, M.; Padron Soler, E.

    1986-01-01

    It is known that strains of E. Coli with wild genotype for reparation, when are irradiated at temperature between 42 0 C and 45 0 C, shown an increase of radioresistance. At the given temperature the number of double strands breaks of DNA decrease. Some authors report that the radioresistance increased is due to the elevation of the irradiation temperature is related to the cell membrane status. The paper includes reports on the effects of increased temperature on the sensitivity - at gamma quantum - of Bacillus licheniformis RI 75-1 vegetative cells. Temperatures of 42 0 C and 60 0 C during irradiation were employed. An increase in radioresistance was found when the temperature of irradiation was increased to 42 0 C. However, a decrease in viability was observed. Heat treatment prior to irradiation showed an increase in the number of radioresistance colonies when compared. (author)

  15. Study and realization of pixelated APD Geiger photodetectors of very high sensitivity for Very High Energy gamma astronomy

    Jradi, K.

    2010-07-01

    Very High Energy gamma ray astronomy uses till now exclusively as detector the Photomultiplier Tube (PMT) to collect weak light flux of atmospheric showers. But an alternative is now emerging: Avalanche Photodiodes polarized in Geiger mode called 'Geiger-APD'. The PMT is a detector designed in the 70's which presents many advantages but also suffers from several drawbacks: size, weight, cost, sensitivity to magnetic field but especially difficulty to realize its pixelation in matrix. Geiger-APDs are semi-conductor devices made of PN junction integrated in a special technology to detect very low light flux, thanks to the polarization beyond the avalanche voltage. Geiger-APD presents very high photoelectron gain (∼106) strongly dependant on the polarization voltage beyond avalanche. These photodiodes present many advantages with respect to PMT, mainly as concerns miniaturization for applications based on imaging, such as the detection of Cerenkov flashes in gamma ray astronomy. In this thesis, we present the study, the design and the realization of a technological structure, based on Silicon. This structure has shown reliability to detect weak luminous flux with breakdown voltage at 12 V and dark current below 10 pA at breakdown. We also developed several models, physical and electrical, necessary to the technological optimization, as well to the development of control and readout circuits, i.e. the basis of any imaging technology. The work presented here consists in the study, the design and the realization of a matrix of high sensitivity pixels. A project of a Cerenkov telescope based on this innovative technology is also presented. (author)

  16. Study of the heterogeneities effect in the dose distributions of Leksell Gamma Knife (R), through Monte Carlo simulation

    Rojas C, E.L.; Al-Dweri, F.M.O.; Lallena R, A.M.

    2005-01-01

    In this work they are studied, by means of Monte Carlo simulation, the effects that take place in the dose profiles that are obtained with the Leksell Gamma Knife (R), when they are kept in account heterogeneities. The considered heterogeneities simulate the skull and the spaces of air that are in the head, like they can be the nasal breasts or the auditory conduits. The calculations were made using the Monte Carlo Penelope simulation code (v. 2003). The geometry of each one of the 201 sources that this instrument is composed, as well as of the corresponding channels of collimation of the Gamma Knife (R), it was described by means of a simplified model of geometry that has been recently studied. The obtained results when they are kept in mind the heterogeneities they present non worthless differences regarding those obtained when those are not considered. These differences are maximum in the proximities of the interfaces among different materials. (Author)

  17. Sensitivity of a Simulated Derecho Event to Model Initial Conditions

    Wang, Wei

    2014-05-01

    Since 2003, the MMM division at NCAR has been experimenting cloud-permitting scale weather forecasting using Weather Research and Forecasting (WRF) model. Over the years, we've tested different model physics, and tried different initial and boundary conditions. Not surprisingly, we found that the model's forecasts are more sensitive to the initial conditions than model physics. In 2012 real-time experiment, WRF-DART (Data Assimilation Research Testbed) at 15 km was employed to produce initial conditions for twice-a-day forecast at 3 km. On June 29, this forecast system captured one of the most destructive derecho event on record. In this presentation, we will examine forecast sensitivity to different model initial conditions, and try to understand the important features that may contribute to the success of the forecast.

  18. Effect of air on speed of insulating material deterioration under simulated LOCA environment. [Gamma radiation

    Kusama, Yasuo; Yagi, Toshiaki; Ito, Masayuki; Okada, Sohei; Yoshikawa, Masato (Japan Atomic Energy Research Inst., Takasaki, Gunma. Takasaki Radiation Chemistry Research Establishment)

    1982-12-01

    To examine the quality approval testing method for the electric cables used for nuclear reactors, various covering insulating materials employed for the cables have been investigated from all angles. The factors which are considered to affect the deterioration of cable materials in a simulated LOCA (loss of coolant accident) environmental test are numerous. This paper reports on the result of investigation on the effect of air on the rate of deterioration of various organic materials usually used as the insulating and covering materials for the cables. Five kinds of polymer sheets (1 mm thick) used for reactor cables were employed as samples. The samples of both standard compounding ratio and the compounding ratio for practical reactor use were tested. As the deterioration prior to LOCA simulation, the thermal deterioration corresponding to 40 years aging (at 121 deg C for 7 days) was given, and subsequently, 50 Mrad gamma -irradiation at 1 Mrad/h was performed in the air. After that, the samples were subject to LOCA simulated environment. Since the results were different according to the kinds of samples, those are described separately for Hypalon, ethylene propylene rubber, cross-linked polyethylene, chloroprene and silicone rubber. The existence of air under LOCA environment accelerated the deterioration of insulation materials except silicone rubber, though its influence differed to the polymers. These materials swelled in the presence of air, and the degree of swelling increased with the temperature, having the close relation to oxidation deterioration. Polyethylene was more susceptible to the effect of air, and silicone rubber was rather stable. The samples of fire-retardant compounding ratio more swelled by water absorption than those of standard compounding ratio.

  19. Gamma-Ray Burst Dynamics and Afterglow Radiation from Adaptive Mesh Refinement, Special Relativistic Hydrodynamic Simulations

    De Colle, Fabio; Granot, Jonathan; López-Cámara, Diego; Ramirez-Ruiz, Enrico

    2012-02-01

    We report on the development of Mezcal-SRHD, a new adaptive mesh refinement, special relativistic hydrodynamics (SRHD) code, developed with the aim of studying the highly relativistic flows in gamma-ray burst sources. The SRHD equations are solved using finite-volume conservative solvers, with second-order interpolation in space and time. The correct implementation of the algorithms is verified by one-dimensional (1D) and multi-dimensional tests. The code is then applied to study the propagation of 1D spherical impulsive blast waves expanding in a stratified medium with ρvpropr -k , bridging between the relativistic and Newtonian phases (which are described by the Blandford-McKee and Sedov-Taylor self-similar solutions, respectively), as well as to a two-dimensional (2D) cylindrically symmetric impulsive jet propagating in a constant density medium. It is shown that the deceleration to nonrelativistic speeds in one dimension occurs on scales significantly larger than the Sedov length. This transition is further delayed with respect to the Sedov length as the degree of stratification of the ambient medium is increased. This result, together with the scaling of position, Lorentz factor, and the shock velocity as a function of time and shock radius, is explained here using a simple analytical model based on energy conservation. The method used for calculating the afterglow radiation by post-processing the results of the simulations is described in detail. The light curves computed using the results of 1D numerical simulations during the relativistic stage correctly reproduce those calculated assuming the self-similar Blandford-McKee solution for the evolution of the flow. The jet dynamics from our 2D simulations and the resulting afterglow light curves, including the jet break, are in good agreement with those presented in previous works. Finally, we show how the details of the dynamics critically depend on properly resolving the structure of the relativistic flow.

  20. GAMMA-RAY BURST DYNAMICS AND AFTERGLOW RADIATION FROM ADAPTIVE MESH REFINEMENT, SPECIAL RELATIVISTIC HYDRODYNAMIC SIMULATIONS

    De Colle, Fabio; Ramirez-Ruiz, Enrico; Granot, Jonathan; López-Cámara, Diego

    2012-01-01

    We report on the development of Mezcal-SRHD, a new adaptive mesh refinement, special relativistic hydrodynamics (SRHD) code, developed with the aim of studying the highly relativistic flows in gamma-ray burst sources. The SRHD equations are solved using finite-volume conservative solvers, with second-order interpolation in space and time. The correct implementation of the algorithms is verified by one-dimensional (1D) and multi-dimensional tests. The code is then applied to study the propagation of 1D spherical impulsive blast waves expanding in a stratified medium with ρ∝r –k , bridging between the relativistic and Newtonian phases (which are described by the Blandford-McKee and Sedov-Taylor self-similar solutions, respectively), as well as to a two-dimensional (2D) cylindrically symmetric impulsive jet propagating in a constant density medium. It is shown that the deceleration to nonrelativistic speeds in one dimension occurs on scales significantly larger than the Sedov length. This transition is further delayed with respect to the Sedov length as the degree of stratification of the ambient medium is increased. This result, together with the scaling of position, Lorentz factor, and the shock velocity as a function of time and shock radius, is explained here using a simple analytical model based on energy conservation. The method used for calculating the afterglow radiation by post-processing the results of the simulations is described in detail. The light curves computed using the results of 1D numerical simulations during the relativistic stage correctly reproduce those calculated assuming the self-similar Blandford-McKee solution for the evolution of the flow. The jet dynamics from our 2D simulations and the resulting afterglow light curves, including the jet break, are in good agreement with those presented in previous works. Finally, we show how the details of the dynamics critically depend on properly resolving the structure of the relativistic flow.

  1. GAMMA-RAY BURST DYNAMICS AND AFTERGLOW RADIATION FROM ADAPTIVE MESH REFINEMENT, SPECIAL RELATIVISTIC HYDRODYNAMIC SIMULATIONS

    De Colle, Fabio; Ramirez-Ruiz, Enrico [Astronomy and Astrophysics Department, University of California, Santa Cruz, CA 95064 (United States); Granot, Jonathan [Racah Institute of Physics, Hebrew University, Jerusalem 91904 (Israel); Lopez-Camara, Diego [Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, Ap. 70-543, 04510 D.F. (Mexico)

    2012-02-20

    We report on the development of Mezcal-SRHD, a new adaptive mesh refinement, special relativistic hydrodynamics (SRHD) code, developed with the aim of studying the highly relativistic flows in gamma-ray burst sources. The SRHD equations are solved using finite-volume conservative solvers, with second-order interpolation in space and time. The correct implementation of the algorithms is verified by one-dimensional (1D) and multi-dimensional tests. The code is then applied to study the propagation of 1D spherical impulsive blast waves expanding in a stratified medium with {rho}{proportional_to}r{sup -k}, bridging between the relativistic and Newtonian phases (which are described by the Blandford-McKee and Sedov-Taylor self-similar solutions, respectively), as well as to a two-dimensional (2D) cylindrically symmetric impulsive jet propagating in a constant density medium. It is shown that the deceleration to nonrelativistic speeds in one dimension occurs on scales significantly larger than the Sedov length. This transition is further delayed with respect to the Sedov length as the degree of stratification of the ambient medium is increased. This result, together with the scaling of position, Lorentz factor, and the shock velocity as a function of time and shock radius, is explained here using a simple analytical model based on energy conservation. The method used for calculating the afterglow radiation by post-processing the results of the simulations is described in detail. The light curves computed using the results of 1D numerical simulations during the relativistic stage correctly reproduce those calculated assuming the self-similar Blandford-McKee solution for the evolution of the flow. The jet dynamics from our 2D simulations and the resulting afterglow light curves, including the jet break, are in good agreement with those presented in previous works. Finally, we show how the details of the dynamics critically depend on properly resolving the structure of the

  2. Ligase-deficient yeast cells exhibit defective DNA rejoining and enhanced gamma ray sensitivity

    Moore, C.W.

    1982-01-01

    Yeast cells deficient in DNA ligase were also deficient in their capacity to rejoin single-strand scissions in prelabeled nuclear DNA. After high-dose-rate gamma irradiation (10 and 25 krads), cdc9-9 mutant cells failed to rejoin single-strand scissions at the restrictive temperature of 37 0 C. In contrast, parental (CDC9) cells (incubated with mutant cells both during and after irradiation) exhibited rapid medium-independent DNA rejoining after 10 min of post-irradiation incubation and slower rates of rejoining after longer incubation. Parental cells were also more resistant than mutant cells to killing by gamma irradiation. Approximately 2.5 +- 0.07 and 5.7 +- 0.6 single-strand breaks per 10 8 daltons were detected in DNAs from either CDC9 or cdc9-9 cells converted to spheroplasts immediately after 10 and 25 krads of irradiation, respectively. At the permissive temperature of 23 0 C, the cdc9-9 cells contained 2 to 3 times the number of DNA single-strand breaks as parental cells after 10 min to 4 h of incubation after 10 krads of irradiation, and two- to eightfold more breaks after 10 min to 2.5 h of incubation after 25 krads of irradiation. Rejoining of single-strand scissions was faster in medium. After only 10 min in buffered growth medium after 10 krads of irradiation, the number of DNA single-strand breaks was reduced to 0.32 +- 0.3 (at 23 0 C) or 0.21 +- 0.05 (at 37 0 C) per 10 8 daltons in parental cells, but remained at 2.1 +- 0.06 (at 23 0 C) or 2.3 +- 0.07 (at 37 0 C) per 10 8 daltons in mutant cells. After 10 or 25 krads of irradiation plus 1 h of incubation in medium at 37 0 C, only DNA from CDC9 cells was rejoined to the size of DNA from unirradiated cells, whereas at 23 0 C, DNAs in both strains were completely rejoined

  3. Comparison of film sensitivity for sup(99m)Tc gamma-rays

    Kojima, Kazuhiko; Katayama, Masaharu; Hisada, Kinichi.

    1975-01-01

    Recently a new method of γ-ray imaging by holography has been studied at several nuclear medical laboratories. The holography is of a very simple. An axis Fresnel zone plate made of lead (2 mm thickness) is placed between the γ-ray source and a detector, and its shadow is recorded as a hologram. The hologram obtained is illuminated by parallel beams of He-Ne laser (6328 A), and an image of the radioisotope distribution in the object is reconstructed by diffraction. The better the resolution of the shadow hologram, the better are the reconstructed images obtained. For this reason the detector for recording the γ-ray hologram must be selected carefully. Three kinds of medical X-ray film were used as detectors for holograms to compare film sensitivity. Generally these medical X-ray films have poor sensitivity to γ-rays of sup(99m)Tc. In order to intensify the film sensitivity for γ-rays of sup(99m)Tc, combinations of six kinds of intensifying screens were studied. Good film sensitivity was obtained by RP (Kodak Co.) film combined with a KZ-S fluorescent intensifying screen. The fluorescent screen was better than fluorometallic screens with similar properties. Using this film-screen combination, shadow holograms could be recorded for 2-3 minutes and images could be optically reconstructed. (auth.)

  4. The implementation of quality controls of gamma camera functioning and simulation of tomography techniques by Gate and GEANT4

    Ben Ameur, Narjes

    2011-01-01

    The reliability of medical devices is directly linked to the services quality offered to the patient. For this reason, quality control tests should be regularly conducted in every nuclear medicine service according to international norms. Our approach consists on realizing different quality control tests recommended by the Nema norm on a gamma-camera in order to evaluate its performance. The obtained data allowed us to study the different physical phenomena happening during a SPECT exam. It also allowed us to identify those affecting the image quality based on the simulation programmes: GEANT 4 and Gate. The obtained results of the quality control showed that the Gamma-camera has a high performance in terms of spatial resolution, linearity, uniformity and rotational center. The establishment of a model for a gamma-camera Symbia E (Siemens) using a Gate platform confirms the reliability of this platform in the conception and the optimization of the detectors.

  5. Problems involved in quantitative gamma camera scintigraphy. C. Sensitivity and homogeneity

    Erbsmann, F.; Paternot, J.; Piepsz, A.; Dobbeleire, A.; Froideville, J.L.

    1976-01-01

    A constant sensitivity of the scintillation camera is an important feature of quantitative digital scintigraphy and must be controlled as much as other factors. The phantom distribution is an excellent test of the camera adjusment but according to present knowledge cannot be used to make corrections of any kind. The best way to reduce the effect of spatial sensitivity variations is to use the same part of the detector constantly to measure the standard as well as the two successive kidneys. Users who wish to measure the uptake of both kidneys simultaneously are advised to measure the standard in the approximate position of the two kidneys and to check that the count rate difference is not more than 5% for example, a higher value requiring a camera adjustment [fr

  6. Simulation of gamma-ray irradiation of lettuce leaves in a 137Cs irradiator using MCNP

    Kim, Jongsoon; Moreira, Rosana G.; Braby, Leslie A.

    2010-01-01

    Ionizing radiation effectively reduces the number of common microbial pathogens in fresh produce. However, the efficacy of the process for pathogens internalized into produce tissue is unknown. The objective of this study was to understand gamma irradiation of lettuce leaf structure exposed in a 137 Cs irradiator using MCNP. The simulated 137 Cs irradiator is a self-shielded device, and its geometry and sources are described in the MCNP input file. When the irradiation chamber is filled with water, lower doses are found at the center of the irradiation volume and the dose uniformity ratio (maximum dose/minimum dose) is 1.76. For randomly oriented rectangular lettuce leaf segments in the irradiation chamber, the dose uniformity ratio is 1.25. It shows that dose uniformity in the Cs irradiator is strongly dependent of the density of the sample. To understand dose distribution inside the leaf, we divided a lettuce leaf into a low density (flat) region (0.72 g/cm 3 ) and high density (rib) region (0.86 g/cm 3 ). Calculated doses to the rib are 61% higher than doses to the flat region of the leaf. This indicates that internalized microorganisms can be inactivated more easily than organisms on the surface. This study shows that irradiation can effectively reduce viable microorganism internalized in lettuce. (author)

  7. Aging simulation of the tailings from Stava fluorite extraction by exposure to gamma rays

    Gianluca Bella

    Full Text Available Abstract Tailings storage facilities are disposal systems for storing the waste products of the mining industry consisting of a slurry mixture made of soil, rock and water that remain after the mineral values have been removed from the patent ore. Tailings dams are supposed to last forever, so after their deposition, tailings can experience aging processes with physical and chemical changes depending on the interactions between local conditions and source mineralogy. The consequences of these aging processes are increased interlocking of particles and oxidation processes, sometimes making previously safely held contaminants available and mobile. Among the long-term aging processes, the natural ionizing radiation (from radioactive isotopes of the soils, cosmic rays, and also ultraviolet rays from the sun can be considered, as proposed in the current research. Furthermore, in many countries, tailings are beginning to be re-used as backfill, landscaping material or feedstock for cement and concrete. So if any, the long-term physical and chemical modifications could affect the hydraulic and mechanical behaviour of tailings with relevant economic consequences. For these reasons, wet and dry silty samples of tailings spilled out after the failure of the Stava tailings dam (Trentino Alto Adige, Italy were exposed to gamma rays, as an accelerated aging technique to simulate the natural ionizing radiation, and then characterized. The modifications on physical and chemical properties were observed and, despite certain chemical stability, some physical changes were observed, particularly in terms of size particle distribution, inner porosity of the particles and specific surface.

  8. Aging simulation of the tailings from Stava fluorite extraction by exposure to gamma rays

    Bella, Gianluca; Barbero, Monica; Barpi, Fabrizio, E-mail: gianluca.bella@polito.it, E-mail: monica.barbero@polito.it, E-mail: fabrizio.barpi@polito.it [Politecnico di Torino - DISEG (Italy); Lameiras, Fernando Soares, E-mail: fsl@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Espósito, Terezinha de Jesus, E-mail: esposito@etg.ufmg.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Transporte e Engenharia Geotécnica

    2017-10-15

    Tailings storage facilities are disposal systems for storing the waste products of the mining industry consisting of a slurry mixture made of soil, rock and water that remain after the mineral values have been removed from the patent ore. Tailings dams are supposed to last forever, so after their deposition, tailings can experience aging processes with physical and chemical changes depending on the interactions between local conditions and source mineralogy. The consequences of these aging processes are increased interlocking of particles and oxidation processes, sometimes making previously safely held contaminants available and mobile. Among the long-term aging processes, the natural ionizing radiation (from radioactive isotopes of the soils, cosmic rays, and also ultraviolet rays from the sun) can be considered, as proposed in the current research. Furthermore, in many countries, tailings are beginning to be re-used as backfill, landscaping material or feedstock for cement and concrete. So if any, the long-term physical and chemical modifications could affect the hydraulic and mechanical behaviour of tailings with relevant economic consequences. For these reasons, wet and dry silty samples of tailings spilled out after the failure of the Stava tailings dam (Trentino Alto Adige, Italy) were exposed to gamma rays, as an accelerated aging technique to simulate the natural ionizing radiation, and then characterized. The modifications on physical and chemical properties were observed and, despite certain chemical stability, some physical changes were observed, particularly in terms of size particle distribution, inner porosity of the particles and specific surface. (author)

  9. Development of divertor simulation research in the GAMMA 10/PDX tandem mirror

    Nakashima, Y.; Sakamoto, M.; Yoshikawa, M.; Oki, K.; Takeda, H.; Ichimura, K.; Hosoi, K.; Hirata, M.; Ichimura, M.; Ikezoe, R.; Imai, T.; Kariya, T.; Katanuma, I.; Kohagura, J.; Minami, R.; Numakura, T.; Wang, X.; Iwamoto, M.; Hosoda, Y.; Asakura, Nobuyuki; Fukumoto, Masakatsu; Kubo, Hirotaka; Hatayama, A.; Hirooka, Y.; Masuzaki, S.; Sagara, A.; Shoji, M.; Kado, S.; Matsuura, H.; Nagata, S.; Shikama, T.; Nishino, N.; Ohno, N.; Tonegawa, A.; Ueda, Y.

    2014-10-01

    This paper describes the recent development of divertor simulation research towards the characterization and control of the detached plasma. In the end-mirror of large tandem mirror device GAMMA 10/PDX, additional ICRF heating experiments in the anchor-cells significantly increases the density in both the anchor and the central cells, which attained the highest particle flux up to 1.7×10 23 particles/s·m 2 at the end-mirror exit. Massive gas injection (H 2 and noble gases) to enhance the radiation cooling in divertor simulation experimental module (D-module) was performed and we have succeeded for the first time in achieving detachment of high temperature plasma equivalent to the SOL plasma of tokamaks by using linear device. A remarkable reduction of the electron temperature (from few tens eV to < 3 eV) on the target plate was successfully achieved associated with the strong reduction of particle and heat fluxes. Two-dimensional image of Hα emission in D-module observed with high-speed camera showed the bright emission in upstream region and strong reduction near the target plate. These results indicate radiation cooling and formation of detached plasma due to gas injection. It is also found that Xe gas is much effective on achieving detached plasma than Ar gas. Simultaneous injection of noble gas and hydrogen gas showed the most effective results on detached plasma generation, which indicates the effect of molecular activated recombination (MAR) processes. The above results will contribute to establishment of detached plasma control and clarification of radiation cooling mechanism towards the development of future divertor systems. (author)

  10. Studies of the sensitivity dependence of float zone silicon diodes on gamma absorbed dose

    Pascoalino, K.C.S.; Santos, T.C. dos; Barbosa, R.F.; Camargo, F. de; Goncalves, J.A.C.; Bueno, C.C.

    2011-01-01

    Full text: Several advantages of silicon diodes which include small size, low cost, high sensitivity and wide availability, make them suitable for dosimetry and for radiation field mapping. However, the small radiation tolerance of ordinary silicon devices has imposed constraints on their application in intense radiation fields such as found in industrial radiation processes. This scenario has been changed with the development of radiation hard silicon devices to be used as track detectors in high-energy physics experiments. Particularly, in this work it is presented the dosimetric results obtained with a batch of nine junction silicon diodes developed, in the framework of CERN RD50 Collaboration, as good candidates for improved radiation hardness. These diodes were produced with 300 micrometer n-type silicon substrate grown by standard float zone technique and processed by the Microelectronics Center of Helsinki University of Technology. The samples irradiation was performed using a Co-60 irradiator (Gammacell 220) which delivers a dose-rate of 2 kGy/h. During the irradiation, the unbiased diodes were connected through low-noise coaxial cables to the input of a KEITHLEY 617 electrometer, in order to monitor the devices photocurrent as a function of the exposure time. To study the response uniformity of the batch of nine diodes as well the sensitivity dependence on the absorbed dose, they were irradiated with different doses from 5 kGy up to 50 kGy. The sensitivity response of each device was investigated through the on-line measurements of the current signals as a function of the exposure time. For doses up to 5 kGy, all diodes exhibited a current decay of almost six percent in comparison with the value registered at the start-time of the irradiation. However, this decrease in the current sensitivity is much smaller than those observed with ordinary diodes for the same absorbed dose. The dose-response curves of the devices were also investigated through the plot

  11. Chromatin structure influences the sensitivity of DNA to gamma-radiation

    Falk, Martin; Lukášová, Emilie; Kozubek, Stanislav

    2008-01-01

    Roč. 1783, č. 12 (2008), s. 2398-2414 ISSN 0167-4889 R&D Projects: GA ČR(CZ) GP204/06/P349; GA AV ČR(CZ) IAA500040802; GA AV ČR(CZ) 1QS500040508 Grant - others:GA MŠk(CZ) LC535 Program:LC Institutional research plan: CEZ:AV0Z50040507; CEZ:AV0Z50040702 Keywords : sensitivity to DNA double- strand breaks induction * DSB repair * higher-order chromatin structure Subject RIV: BO - Biophysics Impact factor: 4.893, year: 2008

  12. A position sensitive gamma-ray detector which employs photodiode and CsI (T1) crystals

    Dean, A.J.; Graham, G.; Hopkins, C.J.; Ramsden, D.; Lei, M.

    1987-01-01

    A compact CsI(Tl)/photodiode gamma-ray detector is described which is capable of locating the point of interaction of incident gamma-ray photons in the spectral region around 1 MeV. Laboratory tests are used to quantify both the spectral and positional resolutions of the detectors. Their likely application in space gamma-ray astronomy is also discussed

  13. Measurement of planetary surface composition by gamma-ray and neutron spectrometry - Preparatory studies for Mars and for the Moon by numerical simulations

    Gasnault, O.

    1999-01-01

    Gamma-ray and neutron spectrometry sets up a powerful tool of geological and geochemical characterization of planetary surfaces. This method allows to tackle some critical planet science questions: crustal and mantle compositions; ices; volcanism; alteration processes... Most of the neutrons and gamma photons result from the interactions of galactic cosmic rays with matter. The first chapter introduces the physics of these nuclear interactions in planetary soils and in detectors. Our work aims at optimizing the observations by specifying instrumental performances, and by highlighting relations between soil composition and neutron fluxes. Numerical simulations using the GEANT code from CERN support our analysis. The second chapter estimates the performances of the Germanium gamma-ray spectrometer for MARS SURVEYOR 2001. The result of simulations is compared to calibration measurements; then performances are calculated in flight configuration. The background at Mars is estimated to about 160 c/s. The instrument offers a fine sensitivity to: Fe, Mg, K, Si, Th, Cl and O. It will also be possible to measure U, Ti, H, C, S, Ca and Al. The emission lobes at the surface are calculated too. These measurements shall permit a better understanding of the Martian surface. The last chapter deals with fast neutrons [500 keV; 10 MeV] emitted by the Moon. The strong influence of oxygen is underlined. As observed by LUNAR PROSPECTOR, the integrated flux shows a pronounced dependence with regolith content in iron and titanium, allowing the mapping. The influence of the other chemical elements is quantified. A simple mathematical formula is suggested to estimate the integrated neutron flux according to soil composition. At last, a study of hydrogen effects on fast neutron flux is carried out; we examine the possibilities to quantify its abundance in the soil by this method. (author)

  14. Effect of refraction index and thickness of the light guide in the position-sensitive gamma-ray detector using compact PS-PMTs

    Inoue, K.; Saito, H.; Nagashima, Y.; Hyodo, T.; Nagai, Y.; Muramatsu, S.; Nagai, S.

    2000-01-01

    We constructed a position-sensitive gamma-ray detector consisting of an array of BGO scintillators, a light guide and compact PS-PMTs. The effects of refractive index and thickness of the light guide of a glass plate on the detector performance were investigated. A light guide with higher refractive index and smaller thickness is found better for a good spatial resolution.

  15. How sensitive are nanosecond molecular dynamics simulations of proteins to changes in the force field?

    Villa, Alessandra; Fan, Hao; Wassenaar, Tsjerk; Mark, Alan E.

    2007-01-01

    The sensitivity of molecular dynamics simulations to variations in the force field has been examined in relation to a set of 36 structures corresponding to 31 proteins simulated by using different versions of the GROMOS force field. The three parameter sets used (43a1, 53a5, and 53a6) differ

  16. Uncertainty and sensitivity analysis of control strategies using the benchmark simulation model No1 (BSM1)

    Flores-Alsina, Xavier; Rodriguez-Roda, Ignasi; Sin, Gürkan

    2009-01-01

    The objective of this paper is to perform an uncertainty and sensitivity analysis of the predictions of the Benchmark Simulation Model (BSM) No. 1, when comparing four activated sludge control strategies. The Monte Carlo simulation technique is used to evaluate the uncertainty in the BSM1 predict...

  17. Securing Sensitive Flight and Engine Simulation Data Using Smart Card Technology

    Blaser, Tammy M.

    2003-01-01

    NASA Glenn Research Center has developed a smart card prototype capable of encrypting and decrypting disk files required to run a distributed aerospace propulsion simulation. Triple Data Encryption Standard (3DES) encryption is used to secure the sensitive intellectual property on disk pre, during, and post simulation execution. The prototype operates as a secure system and maintains its authorized state by safely storing and permanently retaining the encryption keys only on the smart card. The prototype is capable of authenticating a single smart card user and includes pre simulation and post simulation tools for analysis and training purposes. The prototype's design is highly generic and can be used to protect any sensitive disk files with growth capability to urn multiple simulations. The NASA computer engineer developed the prototype on an interoperable programming environment to enable porting to other Numerical Propulsion System Simulation (NPSS) capable operating system environments.

  18. Determination of correction factors for borehole natural gamma-ray measurements by Monte Carlo simulations

    Maucec, M.; Hendriks, Peter; Limburg, J.; de Meijer, R. J.

    2009-01-01

    The analysis of natural gamma-ray spectra measured in boreholes has to take into account borehole parameters such as the presence of casings and borehole diameter. For large, high-efficiency gamma-ray detectors, such as BGO-based systems, which employ full-spectrum data analysis, corresponding

  19. Genetic analysis of gamma-ray mutagenesis in yeast. I. Reversion in radiation-sensitive strains

    McKee, R.H.; Lawrence, C.W.

    1979-01-01

    The frequency of revertants induced by 60 Co γ rays of the ochre allele, cyc1-9, has been measured in radiation-sensitive strains carrying one of 19 nonallelic mutations and in wild-type strains. The results indicate that ionizing radiation mutagenesis depends on the activity of the RAD6 group of genes and that the gene functions employed are very similar, but probably not identical, to those that mediate uv mutagenesis. Repair activities dependent on the functions of the RAD50 through RAD57 loci, the major pathway for the repair of damage caused by ionizing radiation, do not appear to play any part in mutagenesis. A comparison between the γ-ray data and those obtained previously with uv and chemical mutagens suggests that the RAD6 mutagenic pathway is in fact composed of a set of processes, some of which are concerned with error-prone, and some with error-free, recovery activities

  20. On the development of a comprehensive MC simulation model for the Gamma Knife Perfexion radiosurgery unit

    Pappas, E. P.; Moutsatsos, A.; Pantelis, E.; Zoros, E.; Georgiou, E.; Torrens, M.; Karaiskos, P.

    2016-02-01

    This work presents a comprehensive Monte Carlo (MC) simulation model for the Gamma Knife Perfexion (PFX) radiosurgery unit. Model-based dosimetry calculations were benchmarked in terms of relative dose profiles (RDPs) and output factors (OFs), against corresponding EBT2 measurements. To reduce the rather prolonged computational time associated with the comprehensive PFX model MC simulations, two approximations were explored and evaluated on the grounds of dosimetric accuracy. The first consists in directional biasing of the 60Co photon emission while the second refers to the implementation of simplified source geometric models. The effect of the dose scoring volume dimensions in OF calculations accuracy was also explored. RDP calculations for the comprehensive PFX model were found to be in agreement with corresponding EBT2 measurements. Output factors of 0.819  ±  0.004 and 0.8941  ±  0.0013 were calculated for the 4 mm and 8 mm collimator, respectively, which agree, within uncertainties, with corresponding EBT2 measurements and published experimental data. Volume averaging was found to affect OF results by more than 0.3% for scoring volume radii greater than 0.5 mm and 1.4 mm for the 4 mm and 8 mm collimators, respectively. Directional biasing of photon emission resulted in a time efficiency gain factor of up to 210 with respect to the isotropic photon emission. Although no considerable effect on relative dose profiles was detected, directional biasing led to OF overestimations which were more pronounced for the 4 mm collimator and increased with decreasing emission cone half-angle, reaching up to 6% for a 5° angle. Implementation of simplified source models revealed that omitting the sources’ stainless steel capsule significantly affects both OF results and relative dose profiles, while the aluminum-based bushing did not exhibit considerable dosimetric effect. In conclusion, the results of this work suggest that any PFX

  1. Assessment of the suitability of different random number generators for Monte Carlo simulations in gamma-ray spectrometry

    Cornejo Diaz, N.; Vergara Gil, A.; Jurado Vargas, M.

    2010-01-01

    The Monte Carlo method has become a valuable numerical laboratory framework in which to simulate complex physical systems. It is based on the generation of pseudo-random number sequences by numerical algorithms called random generators. In this work we assessed the suitability of different well-known random number generators for the simulation of gamma-ray spectrometry systems during efficiency calibrations. The assessment was carried out in two stages. The generators considered (Delphi's linear congruential, mersenne twister, XorShift, multiplier with carry, universal virtual array, and non-periodic logistic map based generator) were first evaluated with different statistical empirical tests, including moments, correlations, uniformity, independence of terms and the DIEHARD battery of tests. In a second step, an application-specific test was conducted by implementing the generators in our Monte Carlo program DETEFF and comparing the results obtained with them. The calculations were performed with two different CPUs, for a typical HpGe detector and a water sample in Marinelli geometry, with gamma-rays between 59 and 1800 keV. For the Non-periodic Logistic Map based generator, dependence of the most significant bits was evident. This explains the bias, in excess of 5%, of the efficiency values obtained with this generator. The results of the application-specific assessment and the statistical performance of the other algorithms studied indicate their suitability for the Monte Carlo simulation of gamma-ray spectrometry systems for efficiency calculations.

  2. Assessment of the suitability of different random number generators for Monte Carlo simulations in gamma-ray spectrometry.

    Díaz, N Cornejo; Gil, A Vergara; Vargas, M Jurado

    2010-03-01

    The Monte Carlo method has become a valuable numerical laboratory framework in which to simulate complex physical systems. It is based on the generation of pseudo-random number sequences by numerical algorithms called random generators. In this work we assessed the suitability of different well-known random number generators for the simulation of gamma-ray spectrometry systems during efficiency calibrations. The assessment was carried out in two stages. The generators considered (Delphi's linear congruential, mersenne twister, XorShift, multiplier with carry, universal virtual array, and non-periodic logistic map based generator) were first evaluated with different statistical empirical tests, including moments, correlations, uniformity, independence of terms and the DIEHARD battery of tests. In a second step, an application-specific test was conducted by implementing the generators in our Monte Carlo program DETEFF and comparing the results obtained with them. The calculations were performed with two different CPUs, for a typical HpGe detector and a water sample in Marinelli geometry, with gamma-rays between 59 and 1800 keV. For the Non-periodic Logistic Map based generator, dependence of the most significant bits was evident. This explains the bias, in excess of 5%, of the efficiency values obtained with this generator. The results of the application-specific assessment and the statistical performance of the other algorithms studied indicate their suitability for the Monte Carlo simulation of gamma-ray spectrometry systems for efficiency calculations. Copyright 2009 Elsevier Ltd. All rights reserved.

  3. Application of Nonnegative Tensor Factorization for neutron-gamma discrimination of Monte Carlo simulated fission chamber’s output signals

    Mounia Laassiri

    Full Text Available For efficient exploitation of research reactors, it is important to discern neutron flux distribution inside the reactor with the best possible precision. For this reason, fission and ionization chambers are used to measure the neutron field. In these arrays, the sequences of the neutron interaction points in the fission chamber can correctly be identified in order to obtain true neutron energies emitted by nuclei of interest. However, together with the neutrons, gamma-rays are also emitted from nuclei and thereby affect neutron spectra. The originality of this study consists in the application of tensor based blind source separation methods to extract independent components from signals recorded at the fission chamber preamplifier’s output. The objective is to achieve software neutron-gamma discrimination using Nonnegative Tensor Factorization tools. For reasons of nuclear safety, we first simulate the neutron flux inside the TRIGA Mark II Reactor using Monte Carlo methods under Geant4 platform linked to Garfield++. Geant4 simulations allow the fission chamber construction whereas linking the model to Garfield++ permits to simulate drift parameters from the ionization of the filling gas, which is not possible otherwise. Keywords: Fission chamber (FC, Geant4, Garfield++, Neutron-gamma discrimination, Nonnegative Tensor Factorization (NTF

  4. Sensitivities of simulated satellite views of clouds to subgrid-scale overlap and condensate heterogeneity

    Hillman, Benjamin R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Marchand, Roger T. [Univ. of Washington, Seattle, WA (United States); Ackerman, Thomas P. [Univ. of Washington, Seattle, WA (United States)

    2017-08-01

    Satellite simulators are often used to account for limitations in satellite retrievals of cloud properties in comparisons between models and satellite observations. The purpose of the simulator framework is to enable more robust evaluation of model cloud properties, so that di erences between models and observations can more con dently be attributed to model errors. However, these simulators are subject to uncertainties themselves. A fundamental uncertainty exists in connecting the spatial scales at which cloud properties are retrieved with those at which clouds are simulated in global models. In this study, we create a series of sensitivity tests using 4 km global model output from the Multiscale Modeling Framework to evaluate the sensitivity of simulated satellite retrievals when applied to climate models whose grid spacing is many tens to hundreds of kilometers. In particular, we examine the impact of cloud and precipitation overlap and of condensate spatial variability. We find the simulated retrievals are sensitive to these assumptions. Specifically, using maximum-random overlap with homogeneous cloud and precipitation condensate, which is often used in global climate models, leads to large errors in MISR and ISCCP-simulated cloud cover and in CloudSat-simulated radar reflectivity. To correct for these errors, an improved treatment of unresolved clouds and precipitation is implemented for use with the simulator framework and is shown to substantially reduce the identified errors.

  5. Global Sensitivity of Simulated Water Balance Indicators Under Future Climate Change in the Colorado Basin

    Bennett, Katrina E.; Urrego Blanco, Jorge R.; Jonko, Alexandra; Bohn, Theodore J.; Atchley, Adam L.; Urban, Nathan M.; Middleton, Richard S.

    2018-01-01

    The Colorado River Basin is a fundamentally important river for society, ecology, and energy in the United States. Streamflow estimates are often provided using modeling tools which rely on uncertain parameters; sensitivity analysis can help determine which parameters impact model results. Despite the fact that simulated flows respond to changing climate and vegetation in the basin, parameter sensitivity of the simulations under climate change has rarely been considered. In this study, we conduct a global sensitivity analysis to relate changes in runoff, evapotranspiration, snow water equivalent, and soil moisture to model parameters in the Variable Infiltration Capacity (VIC) hydrologic model. We combine global sensitivity analysis with a space-filling Latin Hypercube Sampling of the model parameter space and statistical emulation of the VIC model to examine sensitivities to uncertainties in 46 model parameters following a variance-based approach. We find that snow-dominated regions are much more sensitive to uncertainties in VIC parameters. Although baseflow and runoff changes respond to parameters used in previous sensitivity studies, we discover new key parameter sensitivities. For instance, changes in runoff and evapotranspiration are sensitive to albedo, while changes in snow water equivalent are sensitive to canopy fraction and Leaf Area Index (LAI) in the VIC model. It is critical for improved modeling to narrow uncertainty in these parameters through improved observations and field studies. This is important because LAI and albedo are anticipated to change under future climate and narrowing uncertainty is paramount to advance our application of models such as VIC for water resource management.

  6. Caffeine sensitive repair and mutation induction in UV- or. gamma. -ray-irradiated Dictyostelium discoideum

    Kanishi, Nobuji (Tokyo Metropolitan Research Lab. of Public Health (Japan)); Kinjo, Yasuhito; Watanabe, Makoto

    1990-01-01

    It seems that certain kinds of chemical substances increase the distortion in molecules, change the high order microstructures of nuclei and chromosomes, and exert large variation to the function of repairing the damage of genes due to radiation and others, by coupling with DNA, protein or enzyme system. It has been well known that caffeine is one of such compounds, and by coupling with DNA, it increases the damage due to ultraviolet ray and gives the action of obstructing repair in addition to the action of inducing the abnormality of chromosomes and mutation. Dictyostelium discoideum has the simplest nuclear structure, and shows extremely high resistance to radiation by its high restoration ability. The authors have advanced the research by paying attention to its characteristics, and comparing the Dictyostelium discoideum as one model system with the lymphocyte system of higher animals. This time, the authors analyzed the characteristics of two kinds of sensitivity repair process of caffeine, and investigated into their relation with the occurrence of mutation. The experimental method and the results are reported. (K.I.).

  7. Superconducting Gamma/Neutron Spectrometer Task 1 Completion Report Evaluation of Candidate Neutron-Sensitive Materials

    Bell, Z W

    2002-01-01

    A review of the scientific literature regarding boron- and lithium-containing compounds was completed. Information such as Debye temperature, heat capacity, superconductivity properties, physical and chemical characteristics, commercial availability, and recipes for synthesis was accumulated and evaluated to develop a list of neutron-sensitive materials likely to perform properly in the spectrometer. The best candidate borides appear to be MgB sub 2 (a superconductor with T sub c = 39 K), B sub 6 Si, B sub 4 C, and elemental boron; all are commercially available. Among the lithium compounds are LiH, LiAl, Li sub 1 sub 2 Si sub 7 , and Li sub 7 Sn sub 2. These materials have or are expected to have high Debye temperatures and sufficiently low heat capacities at 100 mK to produce a useful signal. The responses of sup 1 sup 0 B and sup 6 Li to a fission neutron spectrum were also estimated. These demonstrated that the contribution of scattering events is no more than 3% in a boron-based system and 1.5% in a lith...

  8. Sensitivity analysis of simulated SOA loadings using a variance-based statistical approach: SENSITIVITY ANALYSIS OF SOA

    Shrivastava, Manish [Pacific Northwest National Laboratory, Richland Washington USA; Zhao, Chun [Pacific Northwest National Laboratory, Richland Washington USA; Easter, Richard C. [Pacific Northwest National Laboratory, Richland Washington USA; Qian, Yun [Pacific Northwest National Laboratory, Richland Washington USA; Zelenyuk, Alla [Pacific Northwest National Laboratory, Richland Washington USA; Fast, Jerome D. [Pacific Northwest National Laboratory, Richland Washington USA; Liu, Ying [Pacific Northwest National Laboratory, Richland Washington USA; Zhang, Qi [Department of Environmental Toxicology, University of California Davis, California USA; Guenther, Alex [Department of Earth System Science, University of California, Irvine California USA

    2016-04-08

    We investigate the sensitivity of secondary organic aerosol (SOA) loadings simulated by a regional chemical transport model to 7 selected tunable model parameters: 4 involving emissions of anthropogenic and biogenic volatile organic compounds, anthropogenic semi-volatile and intermediate volatility organics (SIVOCs), and NOx, 2 involving dry deposition of SOA precursor gases, and one involving particle-phase transformation of SOA to low volatility. We adopt a quasi-Monte Carlo sampling approach to effectively sample the high-dimensional parameter space, and perform a 250 member ensemble of simulations using a regional model, accounting for some of the latest advances in SOA treatments based on our recent work. We then conduct a variance-based sensitivity analysis using the generalized linear model method to study the responses of simulated SOA loadings to the tunable parameters. Analysis of SOA variance from all 250 simulations shows that the volatility transformation parameter, which controls whether particle-phase transformation of SOA from semi-volatile SOA to non-volatile is on or off, is the dominant contributor to variance of simulated surface-level daytime SOA (65% domain average contribution). We also split the simulations into 2 subsets of 125 each, depending on whether the volatility transformation is turned on/off. For each subset, the SOA variances are dominated by the parameters involving biogenic VOC and anthropogenic SIVOC emissions. Furthermore, biogenic VOC emissions have a larger contribution to SOA variance when the SOA transformation to non-volatile is on, while anthropogenic SIVOC emissions have a larger contribution when the transformation is off. NOx contributes less than 4.3% to SOA variance, and this low contribution is mainly attributed to dominance of intermediate to high NOx conditions throughout the simulated domain. The two parameters related to dry deposition of SOA precursor gases also have very low contributions to SOA variance

  9. A detector system for two-dimensional, position-sensitive detection of neutrons and gamma quanta

    Scholz, A.

    1988-08-01

    While the well-known Anger Camera utilizes a large number of photomultiplier tubes, which are arranged in a regular array behind a scintillation crystal, the new detector system makes use of electron optics to transfer the scintillation image of a large scintillation crystal (Li-6-glass) onto a small position detector. Because of this, only few photodetectors are required for position readout, associated with only a small number of amplifier chains and a very simple position reconstruction algorithm. The reduced complexity of the readout electronics ultimately leads to an improved maintainability and reliability of the detector system. A prototype of the new detector system was built and tested. After giving an overview on already known and realized detector configurations, the basic considerations, which led to the final detector design, will be explained. Different methods of detector readout and position determination are discussed. Measurement results which were obtained with the prototype detector system are presented and explained by means of simulation calculations. (orig./HP) [de

  10. Neuronal model with distributed delay: analysis and simulation study for gamma distribution memory kernel.

    Karmeshu; Gupta, Varun; Kadambari, K V

    2011-06-01

    A single neuronal model incorporating distributed delay (memory)is proposed. The stochastic model has been formulated as a Stochastic Integro-Differential Equation (SIDE) which results in the underlying process being non-Markovian. A detailed analysis of the model when the distributed delay kernel has exponential form (weak delay) has been carried out. The selection of exponential kernel has enabled the transformation of the non-Markovian model to a Markovian model in an extended state space. For the study of First Passage Time (FPT) with exponential delay kernel, the model has been transformed to a system of coupled Stochastic Differential Equations (SDEs) in two-dimensional state space. Simulation studies of the SDEs provide insight into the effect of weak delay kernel on the Inter-Spike Interval(ISI) distribution. A measure based on Jensen-Shannon divergence is proposed which can be used to make a choice between two competing models viz. distributed delay model vis-á-vis LIF model. An interesting feature of the model is that the behavior of (CV(t))((ISI)) (Coefficient of Variation) of the ISI distribution with respect to memory kernel time constant parameter η reveals that neuron can switch from a bursting state to non-bursting state as the noise intensity parameter changes. The membrane potential exhibits decaying auto-correlation structure with or without damped oscillatory behavior depending on the choice of parameters. This behavior is in agreement with empirically observed pattern of spike count in a fixed time window. The power spectral density derived from the auto-correlation function is found to exhibit single and double peaks. The model is also examined for the case of strong delay with memory kernel having the form of Gamma distribution. In contrast to fast decay of damped oscillations of the ISI distribution for the model with weak delay kernel, the decay of damped oscillations is found to be slower for the model with strong delay kernel.

  11. Monte Carlo simulation of gamma-ray total counting efficiency for a Phoswich detector

    Yalcin, S. [Education Faculty, Kastamonu University, 37200 Kastamonu (Turkey)], E-mail: syalcin@kastamonu.edu.tr; Gurler, O. [Department of Physics, Faculty of Arts and Sciences, Uludag University, Gorukle Campus, 16059 Bursa (Turkey); Gundogdu, O. [Department of Physics, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford, GU2 7XH (United Kingdom); NCCPM, Medical Physics, Royal Surrey County Hospital, Guildford, GU2 7XX (United Kingdom); Kaynak, G. [Department of Physics, Faculty of Arts and Sciences, Uludag University, Gorukle Campus, 16059 Bursa (Turkey)

    2009-01-15

    The LB 1000-PW detector is mainly used for determining total alpha, beta and gamma activity of low activity natural sources such as water, soil, air filters and any other environmental sources. Detector efficiency needs to be known in order to measure the absolute activity of such samples. This paper presents results on the total gamma counting efficiency of a Phoswich detector from point and disk sources. The directions of photons emitted from the source were determined by Monte Carlo techniques and the true path lengths in the detector were determined by analytical equations depending on photon directions. Results are tabulated for various gamma energies.

  12. Monte Carlo simulation of gamma-ray total counting efficiency for a Phoswich detector

    Yalcin, S.; Gurler, O.; Gundogdu, O.; Kaynak, G.

    2009-01-01

    The LB 1000-PW detector is mainly used for determining total alpha, beta and gamma activity of low activity natural sources such as water, soil, air filters and any other environmental sources. Detector efficiency needs to be known in order to measure the absolute activity of such samples. This paper presents results on the total gamma counting efficiency of a Phoswich detector from point and disk sources. The directions of photons emitted from the source were determined by Monte Carlo techniques and the true path lengths in the detector were determined by analytical equations depending on photon directions. Results are tabulated for various gamma energies

  13. Monte Carlo simulation of the Leksell Gamma KnifeTM: II. Effects of heterogeneous versus homogeneous media for stereotactic radiosurgery

    Moskvin, Vadim; Timmerman, Robert; DesRosiers, Colleen; Randall, Marcus; DesRosiers, Paul; Dittmer, Phil; Papiez, Lech

    2004-01-01

    The absence of electronic equilibrium in the vicinity of bone-tissue or air-tissue heterogeneity in the head can misrepresent deposited dose with treatment planning algorithms that assume all treatment volume as homogeneous media. In this paper, Monte Carlo simulation (PENELOPE) and measurements with a specially designed heterogeneous phantom were applied to investigate the effect of air-tissue and bone-tissue heterogeneity on dose perturbation with the Leksell Gamma Knife TM . The dose fall-off near the air-tissue interface caused by secondary electron disequilibrium leads to overestimation of dose by the vendor supplied treatment planning software (GammaPlan TM ) at up to 4 mm from an interface. The dose delivered to the target area away from an air-tissue interface may be underestimated by up to 7% by GammaPlan TM due to overestimation of attenuation of photon beams passing through air cavities. While the underdosing near the air-tissue interface cannot be eliminated with any plug pattern, the overdosage due to under-attenuation of the photon beams in air cavities can be eliminated by plugging the sources whose beams intersect the air cavity. Little perturbation was observed next to bone-tissue interfaces. Monte Carlo results were confirmed by measurements. This study shows that the employed Monte Carlo treatment planning is more accurate for precise dosimetry of stereotactic radiosurgery with the Leksell Gamma Knife TM for targets in the vicinity of air-filled cavities

  14. Simulation of GRIS spectrometer response to the solar gamma-ray flare of 23 July 2002

    Trofimov, Yu A; Kotov, Yu D; Yurov, V N; Lupar, E E; Faradzhaev, R M; Glyanenko, A S

    2017-01-01

    GRIS is a prospective experiment designed to measure hard X-rays and γ-rays of solar flares in the energy range from 50 keV to 200 MeV as well as solar neutrons > 30 MeV. This study considers results of GEANT 4 simulation of GRIS detectors response to cosmic background radiation and to the solar flare SOL2002-07-23 (X4.8). It is shown that the GRIS spectrometers have enough sensitivity and energy resolution to measure redshifts of some narrow γ-rays in flare spectra, that the low energy thresholds of the detectors can be lowered considerably without a risk of counting rate saturation during high magnitude flares and that at a choice between LaBr 3 (Ce) and CeBr 3 the second one is a preferable scintillator for a hard X-ray and γ-ray spectrometer of solar flares. (paper)

  15. Numerical simulations on efficiency and measurement of capabilities of BGO detectors for high energy gamma ray

    Wen Wan Xin

    2002-01-01

    The energy resolution and time resolution of two phi 75 x 100 BGO detectors for high energy gamma ray newly made were measured with sup 1 sup 3 sup 7 Cs and sup 6 sup 0 Co resources. The two characteristic gamma rays of high energy emitted from the thermal neutron capture of germanium in BGO crystal were used for the energy calibration of gamma spectra. The intrinsic photopeak efficiency, single escape probability and double escape probabilities of BGO detectors in photon energy range of 4-30 MeV are numerically calculated with GEANT code. The real count response and count ratio of the uniformly distributed incident photons in energy range of 0-30 MeV are also calculated. The distortion of gamma spectra caused by the photon energy loss extension to lower energy in detection medium is discussed

  16. Quality and sensitivity of high-resolution numerical simulation of urban heat islands

    Li, Dan; Bou-Zeid, Elie

    2014-05-01

    High-resolution numerical simulations of the urban heat island (UHI) effect with the widely-used Weather Research and Forecasting (WRF) model are assessed. Both the sensitivity of the results to the simulation setup, and the quality of the simulated fields as representations of the real world, are investigated. Results indicate that the WRF-simulated surface temperatures are more sensitive to the planetary boundary layer (PBL) scheme choice during nighttime, and more sensitive to the surface thermal roughness length parameterization during daytime. The urban surface temperatures simulated by WRF are also highly sensitive to the urban canopy model (UCM) used. The implementation in this study of an improved UCM (the Princeton UCM or PUCM) that allows the simulation of heterogeneous urban facets and of key hydrological processes, together with the so-called CZ09 parameterization for the thermal roughness length, significantly reduce the bias (Changing UCMs and PBL schemes does not alter the performance of WRF in reproducing bulk boundary layer temperature profiles significantly. The results illustrate the wide range of urban environmental conditions that various configurations of WRF can produce, and the significant biases that should be assessed before inferences are made based on WRF outputs. The optimal set-up of WRF-PUCM developed in this paper also paves the way for a confident exploration of the city-scale impacts of UHI mitigation strategies in the companion paper (Li et al 2014).

  17. Neutron-induced gamma-ray spectroscopy: simulations for chemical mapping of planetary surfaces

    Brueckner, J.; Waenke, H.; Reedy, R.C.

    1986-01-01

    Cosmic rays interact with the surface of a planetary body and produce a cascade of secondary particles, such as neutrons. Neutron-induced scattering and capture reactions play an important role in the production of discrete gamma-ray lines that can be measured by a gamma-ray spectrometer on board of an orbiting spacecraft. These data can be used to determine the concentration of many elements in the surface of a planetary body, which provides clues to its bulk composition and in turn to its origin and evolution. To investigate the gamma rays made by neutron interactions, thin targets were irradiated with neutrons having energies from 14 MeV to 0.025 eV. By means of foil activation technique the ratio of epithermal to thermal neutrons was determined to be similar to that in the Moon. Gamma rays emitted by the targets and the surrounding material were detected by a high-resolution germanium detector in the energy range of 0.1 to 8 MeV. Most of the gamma-ray lines that are expected to be used for planetary gamma-ray spectroscopy were found in the recorded spectra and the principal lines in these spectra are presented. 58 refs., 7 figs., 9 tabs

  18. High-sensitivity gamma spectroscopy for extended sources. Application to activity measurements on the human body, on glass, and on soil

    Jouve, B.

    1962-01-01

    The measurement and location by gamma spectroscopy of human body internal contaminations at maximum permissible levels, and, in certain cases, at lower activities such as that due to 40 K was investigated. The characteristics of the high-sensitivity apparatus used are given, and several assemblies using large-volume NaI(Tl) scintillators are described. The relatively light shielding required for natural radioactivity permitted construction of mobile assembly. Conditions of use are described, and the results are given. All gamma emitting elements were measured in 15 min at levels lower than the tolerance dose. Gamma spectroscopy was also used to determine fission products in the earth and to study radioactive elements in the presence of other emitters. (author) [fr

  19. An Optimized Design of Single-Channel Beta-Gamma Coincidence Phoswich Detector by Geant4 Monte Carlo Simulations

    Weihua Zhang

    2011-01-01

    Full Text Available An optimized single-channel phoswich well detector design has been proposed and assessed in order to improve beta-gamma coincidence measurement sensitivity of xenon radioisotopes. This newly designed phoswich well detector consists of a plastic beta counting cell (BC404 embedded in a CsI(Tl crystal coupled to a photomultiplier tube. The BC404 is configured in a cylindrical pipe shape to minimise light collection deterioration. The CsI(Tl crystal consists of a rectangular part and a semicylindrical scintillation part as a light reflector to increase light gathering. Compared with a PhosWatch detector, the final optimized detector geometry showed 15% improvement in the energy resolution of a 131mXe 129.4 keV conversion electron peak. The predicted beta-gamma coincidence efficiencies of xenon radioisotopes have also been improved accordingly.

  20. Use of sensitivity-information for the adaptive simulation of thermo-hydraulic system codes

    Kerner, Alexander M.

    2011-01-01

    Within the scope of this thesis the development of methods for online-adaptation of dynamical plant simulations of a thermal-hydraulic system code to measurement data is depicted. The described approaches are mainly based on the use of sensitivity-information in different areas: statistical sensitivity measures are used for the identification of the parameters to be adapted and online-sensitivities for the parameter adjustment itself. For the parameter adjustment the method of a ''system-adapted heuristic adaptation with partial separation'' (SAHAT) was developed, which combines certain variants of parameter estimation and control with supporting procedures to solve the basic problems. The applicability of the methods is shown by adaptive simulations of a PKL-III experiment and by selected transients in a nuclear power plant. Finally the main perspectives for the application of a tracking simulator on a system code are identified.

  1. The noise analysis and optimum filtering techniques for a two-dimensional position sensitive orthogonal strip gamma ray detector employing resistive charge division

    Gerber, M.S.; Muller, D.W.

    1976-01-01

    The analysis of an orthogonal strip, two-dimensional position sensitive high purity germanium gamma ray detector is discussed. Position sensitivity is obtained by connecting each electrode strip on the detector to a resistor network. Charge, entering the network, divides in relation to the resistance between its entry point and the virtual earth points of the charge sensitive preamplifiers located at the end of each resistor network. The difference of the voltage pulses at the output of each preamplifier is proportional to the position at which the charge entered the resistor network and the sum of the pulse is proportional to the energy of the detected gamma ray. The analysis and spatial noise resolution is presented for this type of position sensitive detector. The results of the analysis show that the position resolution is proportional to the square root of the filter amplifier's output pulse time constant and that for energy measurement the resolution is maximized at the filter amplifier's noise corner time constant. The design of the electronic noise filtering system for the prototype gamma ray camera was based on the mathematical energy and spatial resolution equations. For the spatial channel a Gaussian trapezoidal filtering system was developed. Gaussian filtering was used for the energy channel. The detector noise model was verified by taking rms noise measurements of the filtered energy and spatial pulses from resistive readout charge dividing detectors. These measurements were within 10% of theory. (Auth.)

  2. On the Efficient Simulation of the Distribution of the Sum of Gamma-Gamma Variates with Application to the Outage Probability Evaluation Over Fading Channels

    Ben Issaid, Chaouki; Rached, Nadhir B.; Kammoun, Abla; Alouini, Mohamed-Slim; Tempone, Raul

    2017-01-01

    the outage probability achieved by some diversity techniques over this kind of channels is of major practical importance. In many circumstances, this is related to the difficult question of analyzing the statistics of a sum of Gamma- Gamma random variables

  3. Simulation and analysis of sensitivity for tapered fiber Bragg grating evanescent wave sensor

    Xu, Hong-zhi; Lou, Jun; Tan, Yao-cheng; Li, Ben-chong; Huang, Jie; Shen, Wei-min

    2014-12-01

    We have carried out a detailed simulative study of the tapered fiber Bragg grating (TFBG) evanescent wave sensor sensitivity by using 3-D Coupled-Mode Theory method. The method is based on the spectral interrogation mode of operation. We also make numerical simulations to figure out how the uniform waist diameter and the difference of the relative refractive indexes between fiber core and external medium affect the sensitivity of this proposed sensor. The simulation results show that the sensitivity of the tapered fiber Bragg grating will be improved when the diameter of the uniform waist decrease as well as the difference of the relative refractive indexes between fiber core and external medium. And with the fixed uniform waist diameter and tapered length, when the difference of the relative refractive index of fiber core and external medium varies is 0.015RIU, the values of wavelength shift is 5.08nm, the sensitivity of the tapered fiber Bragg grating is 317.5nm/RIU. The sensitivity is higher than that of the common FBG. The results are consistent with theoretical models. The simulation results can supply the guidance for the further experimental study and refractive index sensor design, optimization and application.

  4. Dose mapping simulation using the MCNP code for the Syrian gamma irradiation facility and benchmarking

    Khattab, K.; Boush, M.; Alkassiri, H.

    2013-01-01

    Highlights: • The MCNP4C was used to calculate the gamma ray dose rate spatial distribution in for the SGIF. • Measurement of the gamma ray dose rate spatial distribution using the Chlorobenzene dosimeter was conducted as well. • Good agreements were noticed between the calculated and measured results. • The maximum relative differences were less than 7%, 4% and 4% in the x, y and z directions respectively. - Abstract: A three dimensional model for the Syrian gamma irradiation facility (SGIF) is developed in this paper to calculate the gamma ray dose rate spatial distribution in the irradiation room at the 60 Co source board using the MCNP-4C code. Measurement of the gamma ray dose rate spatial distribution using the Chlorobenzene dosimeter is conducted as well to compare the calculated and measured results. Good agreements are noticed between the calculated and measured results with maximum relative differences less than 7%, 4% and 4% in the x, y and z directions respectively. This agreement indicates that the established model is an accurate representation of the SGIF and can be used in the future to make the calculation design for a new irradiation facility

  5. A new computationally-efficient computer program for simulating spectral gamma-ray logs

    Conaway, J.G.

    1995-01-01

    Several techniques to improve the accuracy of radionuclide concentration estimates as a function of depth from gamma-ray logs have appeared in the literature. Much of that work was driven by interest in uranium as an economic mineral. More recently, the problem of mapping and monitoring artificial gamma-emitting contaminants in the ground has rekindled interest in improving the accuracy of radioelement concentration estimates from gamma-ray logs. We are looking at new approaches to accomplishing such improvements. The first step in this effort has been to develop a new computational model of a spectral gamma-ray logging sonde in a borehole environment. The model supports attenuation in any combination of materials arranged in 2-D cylindrical geometry, including any combination of attenuating materials in the borehole, formation, and logging sonde. The model can also handle any distribution of sources in the formation. The model considers unscattered radiation only, as represented by the background-corrected area under a given spectral photopeak as a function of depth. Benchmark calculations using the standard Monte Carlo model MCNP show excellent agreement with total gamma flux estimates with a computation time of about 0.01% of the time required for the MCNP calculations. This model lacks the flexibility of MCNP, although for this application a great deal can be accomplished without that flexibility

  6. Demonstration of the 3D PANTHERE software for the simulation of gamma dose rates for complex nuclear installations; Demonstration du logiciel 3D panthere pour la simulation des debits de doses gamma pour installations nucleaires complexes

    Longeot, M.; Dupont, B. [EDFISEPTENITE, 12-14 avenue Dutrievoz, 69628 Villeurbanne Cedex (France); Schumm, A.; Zweers, M. [EDF/R and D/SINETICS, 1 avenue du General de Gaulle, 92141 Clamart Cedex (France); Malvagi, F.; Trama, J.C. [CEA Saclay, SERMA, 91 - Gif-sur-Yvette (France)

    2010-07-01

    The authors present the two successive versions of the PANTHERE simulation software developed by EDF-SEPTEN to determine gamma dose flow rate in complex industrial installations. This software predicts dose rates and thus enables interventions in irradiating environment to be optimized. The authors report the demonstration of the industrial version (PANTHEREv1) and of the currently under development version (PANTHEREv2). They outline the evolutions brought to the first version to develop the second one such as the direct importation of CAD models, ergonomic improvements, etc.

  7. Interferon-gamma and tumor necrosis factor-alpha sensitize primarily resistant human endometrial stromal cells to Fas-mediated apoptosis

    Fluhr, Herbert; Krenzer, Stefanie; Stein, Gerburg M

    2007-01-01

    The subtle interaction between the implanting embryo and the maternal endometrium plays a pivotal role during the process of implantation. Human endometrial stromal cells (ESCs) express Fas and the implanting trophoblast cells secrete Fas ligand (FASLG, FasL), suggesting a possible role for Fas......-mediated signaling during early implantation. Here we show that ESCs are primarily resistant to Fas-mediated apoptosis independently of their state of hormonal differentiation. Pre-treatment of ESCs with interferon (IFN)-gamma and tumor necrosis factor (TNF)-alpha sensitizes them to become apoptotic upon stimulation...... of Fas by an agonistic anti-Fas antibody. Incubation of ESCs with the early embryonic signal human chorionic gonadotropin (hCG, CGB) does not influence their reaction to Fas stimulation. The sensitizing effect of IFN-gamma and TNF-alpha was accompanied by a significant upregulation of Fas and FLICE...

  8. Ethical sensitivity intervention in science teacher education: Using computer simulations and professional codes of ethics

    Holmes, Shawn Yvette

    A simulation was created to emulate two Racial Ethical Sensitivity Test (REST) videos (Brabeck et al., 2000). The REST is a reliable assessment for ethical sensitivity to racial and gender intolerant behaviors in educational settings. Quantitative and qualitative analysis of the REST was performed using the Quick-REST survey and an interview protocol. The purpose of this study was to affect science educator ability to recognize instances of racial and gender intolerant behaviors by levering immersive qualities of simulations. The fictitious Hazelton High School virtual environment was created by the researcher and compared with the traditional REST. The study investigated whether computer simulations can influence the ethical sensitivity of preservice and inservice science teachers to racial and gender intolerant behaviors in school settings. The post-test only research design involved 32 third-year science education students enrolled in science education classes at several southeastern universities and 31 science teachers from the same locale, some of which were part of an NSF project. Participant samples were assigned to the video control group or the simulation experimental group. This resulted in four comparison group; preservice video, preservice simulation, inservice video and inservice simulation. Participants experienced two REST scenarios in the appropriate format then responded to Quick-REST survey questions for both scenarios. Additionally, the simulation groups answered in-simulation and post-simulation questions. Nonparametric analysis of the Quick-REST ascertained differences between comparison groups. Cronbach's alpha was calculated for internal consistency. The REST interview protocol was used to analyze recognition of intolerant behaviors in the in-simulation prompts. Post-simulation prompts were analyzed for emergent themes concerning effect of the simulation on responses. The preservice video group had a significantly higher mean rank score than

  9. Simulations of a spectral gamma-ray logging tool response to a surface source distribution on the borehole wall

    Wilson, R.D.; Conaway, J.G.

    1991-01-01

    We have developed Monte Carlo and discrete ordinates simulation models for the large-detector spectral gamma-ray (SGR) logging tool in use at the Nevada Test Site. Application of the simulation models produced spectra for source layers on the borehole wall, either from potassium-bearing mudcakes or from plate-out of radon daughter products. Simulations show that the shape and magnitude of gamma-ray spectra from sources distributed on the borehole wall depend on radial position with in the air-filled borehole as well as on hole diameter. No such dependence is observed for sources uniformly distributed in the formation. In addition, sources on the borehole wall produce anisotropic angular fluxes at the higher scattered energies and at the source energy. These differences in borehole effects and in angular flux are important to the process of correcting SGR logs for the presence of potassium mudcakes; they also suggest a technique for distinguishing between spectral contributions from formation sources and sources on the borehole wall. These results imply the existence of a standoff effect not present for spectra measured in air-filled boreholes from formation sources. 5 refs., 11 figs

  10. Demonstration of the 3D PANTHERE software for the simulation of gamma dose rates for complex nuclear installations

    Longeot, M.; Dupont, B.; Schumm, A.; Zweers, M.; Malvagi, F.; Trama, J.C.

    2010-01-01

    The authors present the two successive versions of the PANTHERE simulation software developed by EDF-SEPTEN to determine gamma dose flow rate in complex industrial installations. This software predicts dose rates and thus enables interventions in irradiating environment to be optimized. The authors report the demonstration of the industrial version (PANTHEREv1) and of the currently under development version (PANTHEREv2). They outline the evolutions brought to the first version to develop the second one such as the direct importation of CAD models, ergonomic improvements, etc.

  11. Sensitivity of vertical jumping performance to changes in muscle stimulation onset times: a simulation study

    Bobbert, M.F.; van Zandwijk, J.P.

    1999-01-01

    The effect of muscle stimulation dynamics on the sensitivity of jumping achievement to variations in timing of muscle stimulation onsets was investigated. Vertical squat jumps were simulated using a forward dynamic model of the human musculoskeletal system. The model calculates the motion of body

  12. Sensitivity analysis by experimental design and metamodelling : case study on simulation in national animal disease control

    Vonk Noordegraaf, A.; Nielen, M.; Kleijnen, J.P.C.

    2003-01-01

    Simulation is a frequently applied tool in the discipline of animal health economics. Application of sensitivity analysis, however, is often limited to changing only one factor at a time (OAT designs). In this study, the statistical techniques of Design of Experiments (DOE) and regression

  13. Using simulations and data to evaluate mean sensitivity (ζ) as a useful statistic in dendrochronology

    Andrew G. Bunn; Esther Jansma; Mikko Korpela; Robert D. Westfall; James Baldwin

    2013-01-01

    Mean sensitivity (ζ) continues to be used in dendrochronology despite a literature that shows it to be of questionable value in describing the properties of a time series. We simulate first-order autoregressive models with known parameters and show that ζ is a function of variance and autocorrelation of a time series. We then use 500 random tree-ring...

  14. Using simulations and data to evaluate mean sensitivity (ζ) as a useful statistic in dendrochronology

    Bunn, A.G.; Jansma, E.; Korpela, M.; Westfall, R.D.; Baldwin, J.

    2013-01-01

    Mean sensitivity (ζ) continues to be used in dendrochronology despite a literature that shows it to be of questionable value in describing the properties of a time series. We simulate first-order autoregressive models with known parameters and show that ζ is a function of variance and

  15. Quantification of remodeling parameter sensitivity - assessed by a computer simulation model

    Thomsen, J.S.; Mosekilde, Li.; Mosekilde, Erik

    1996-01-01

    We have used a computer simulation model to evaluate the effect of several bone remodeling parameters on vertebral cancellus bone. The menopause was chosen as the base case scenario, and the sensitivity of the model to the following parameters was investigated: activation frequency, formation bal....... However, the formation balance was responsible for the greater part of total mass loss....

  16. Airfoil data sensitivity analysis for actuator disc simulations used in wind turbine applications

    Nilsson, Karl; Breton, Simon-Philippe; Sørensen, Jens Nørkær

    2014-01-01

    To analyse the sensitivity of blade geometry and airfoil characteristics on the prediction of performance characteristics of wind farms, large-eddy simulations using an actuator disc (ACD) method are performed for three different blade/airfoil configurations. The aim of the study is to determine ...

  17. SU-G-IeP4-12: Performance of In-111 Coincident Gamma-Ray Counting: A Monte Carlo Simulation

    Pahlka, R; Kappadath, S; Mawlawi, O [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: The decay of In-111 results in a non-isotropic gamma-ray cascade, which is normally imaged using a gamma camera. Creating images with a gamma camera using coincident gamma-rays from In-111 has not been previously studied. Our objective was to explore the feasibility of imaging this cascade as coincidence events and to determine the optimal timing resolution and source activity using Monte Carlo simulations. Methods: GEANT4 was used to simulate the decay of the In-111 nucleus and to model the gamma camera. Each photon emission was assigned a timestamp, and the time delay and angular separation for the second gamma-ray in the cascade was consistent with the known intermediate state half-life of 85ns. The gamma-rays are transported through a model of a Siemens dual head Symbia “S” gamma camera with a 5/8-inch thick crystal and medium energy collimators. A true coincident event was defined as a single 171keV gamma-ray followed by a single 245keV gamma-ray within a specified time window (or vice versa). Several source activities (ranging from 10uCi to 5mCi) with and without incorporation of background counts were then simulated. Each simulation was analyzed using varying time windows to assess random events. The noise equivalent count rate (NECR) was computed based on the number of true and random counts for each combination of activity and time window. No scatter events were assumed since sources were simulated in air. Results: As expected, increasing the timing window increased the total number of observed coincidences albeit at the expense of true coincidences. A timing window range of 200–500ns maximizes the NECR at clinically-used source activities. The background rate did not significantly alter the maximum NECR. Conclusion: This work suggests coincident measurements of In-111 gamma-ray decay can be performed with commercial gamma cameras at clinically-relevant activities. Work is ongoing to assess useful clinical applications.

  18. Maintenance Personnel Performance Simulation (MAPPS) model: description of model content, structure, and sensitivity testing. Volume 2

    Siegel, A.I.; Bartter, W.D.; Wolf, J.J.; Knee, H.E.

    1984-12-01

    This volume of NUREG/CR-3626 presents details of the content, structure, and sensitivity testing of the Maintenance Personnel Performance Simulation (MAPPS) model that was described in summary in volume one of this report. The MAPPS model is a generalized stochastic computer simulation model developed to simulate the performance of maintenance personnel in nuclear power plants. The MAPPS model considers workplace, maintenance technician, motivation, human factors, and task oriented variables to yield predictive information about the effects of these variables on successful maintenance task performance. All major model variables are discussed in detail and their implementation and interactive effects are outlined. The model was examined for disqualifying defects from a number of viewpoints, including sensitivity testing. This examination led to the identification of some minor recalibration efforts which were carried out. These positive results indicate that MAPPS is ready for initial and controlled applications which are in conformity with its purposes

  19. A study of the sensitivity of an imaging telescope (GRITS) for high energy gamma-ray astronomy. Final report

    Yearian, M.R.

    1990-08-01

    When a gamma-ray telescope is placed in Earth orbit, it is bombarded by a flux of cosmic protons much greater than the flux of interesting gammas. These protons can interact in the telescope's thermal shielding to produce detectable gamma rays, most of which are vetoed. Since the proton flux is so high, the unvetoed gamma rays constitute a significant background relative to some weak sources. This background increases the observing time required to pinpoint some sources and entirely obscures other sources. Although recent telescopes have been designed to minimize this background, its strength and spectral characteristics were not previously calculated in detail. Monte Carlo calculations are presented which characterize the strength, spectrum and other features of the cosmic proton background using FLUKA, a hadronic cascade program. Several gamma-ray telescopes, including SAS-2, EGRET and the Gamma Ray Imaging Telescope System (GRITS), are analyzed, and their proton-induced backgrounds are characterized. In all cases, the backgrounds are either shown to be low relative to interesting signals or suggestions are made which would reduce the background sufficiently to leave the telescope unimpaired. In addition, several limiting cases are examined for comparison to previous estimates and calibration measurements

  20. Quality and sensitivity of high-resolution numerical simulation of urban heat islands

    Li, Dan; Bou-Zeid, Elie

    2014-01-01

    High-resolution numerical simulations of the urban heat island (UHI) effect with the widely-used Weather Research and Forecasting (WRF) model are assessed. Both the sensitivity of the results to the simulation setup, and the quality of the simulated fields as representations of the real world, are investigated. Results indicate that the WRF-simulated surface temperatures are more sensitive to the planetary boundary layer (PBL) scheme choice during nighttime, and more sensitive to the surface thermal roughness length parameterization during daytime. The urban surface temperatures simulated by WRF are also highly sensitive to the urban canopy model (UCM) used. The implementation in this study of an improved UCM (the Princeton UCM or PUCM) that allows the simulation of heterogeneous urban facets and of key hydrological processes, together with the so-called CZ09 parameterization for the thermal roughness length, significantly reduce the bias (<1.5 °C) in the surface temperature fields as compared to satellite observations during daytime. The boundary layer potential temperature profiles are captured by WRF reasonable well at both urban and rural sites; the biases in these profiles relative to aircraft-mounted senor measurements are on the order of 1.5 °C. Changing UCMs and PBL schemes does not alter the performance of WRF in reproducing bulk boundary layer temperature profiles significantly. The results illustrate the wide range of urban environmental conditions that various configurations of WRF can produce, and the significant biases that should be assessed before inferences are made based on WRF outputs. The optimal set-up of WRF-PUCM developed in this paper also paves the way for a confident exploration of the city-scale impacts of UHI mitigation strategies in the companion paper (Li et al 2014). (letter)

  1. A simulation of orientation dependent, global changes in camera sensitivity in ECT

    Bieszk, J.A.; Hawman, E.G.; Malmin, R.E.

    1984-01-01

    ECT promises the abilities to: 1) observe radioisotope distributions in a patient without the summation of overlying activity to reduce contrast, and 2) measure quantitatively these distributions to further and more accurately assess organ function. Ideally, camera-based ECT systems should have a performance that is independent of camera orientation or gantry angle. This study is concerned with ECT quantitation errors that can arise from angle-dependent variations of camera sensitivity. Using simulated phantoms representative of heart and liver sections, the effects of sensitivity changes on reconstructed images were assessed both visually and quantitatively based on ROI sums. The sinogram for each test image was simulated with 128 linear digitization and 180 angular views. The global orientation-dependent sensitivity was modelled by applying an angular sensitivity dependence to the sinograms of the test images. Four sensitivity variations were studied. Amplitudes of 0% (as a reference), 5%, 10%, and 25% with a cosθ dependence were studied as well as a cos2θ dependence with a 5% amplitude. Simulations were done with and without Poisson noise to: 1) determine trends in the quantitative effects as a function of the magnitude of the variation, and 2) to see how these effects are manifested in studies having statistics comparable to clinical cases. For the most realistic sensitivity variation (cosθ, 5% ampl.), the ROIs chosen in the present work indicated changes of <0.5% in the noiseless case and <5% for the case with Poisson noise. The effects of statistics appear to dominate any effects due to global, sinusoidal, orientation-dependent sensitivity changes in the cases studied

  2. The sensitivity studies of a landmine explosive detection system based on neutron backscattering using Monte Carlo simulation

    Khan Hamda

    2017-01-01

    Full Text Available This paper carries out a Monte Carlo simulation of a landmine detection system, using the MCNP5 code, for the detection of concealed explosives such as trinitrotoluene and cyclonite. In portable field detectors, the signal strength of backscattered neutrons and gamma rays from thermal neutron activation is sensitive to a number of parameters such as the mass of explosive, depth of concealment, neutron moderation, background soil composition, soil porosity, soil moisture, multiple scattering in the background material, and configuration of the detection system. In this work, a detection system, with BF3 detectors for neutrons and sodium iodide scintillator for g-rays, is modeled to investigate the neutron signal-to-noise ratio and to obtain an empirical formula for the photon production rate Ri(n,γ= SfGfMf(d,m from radiative capture reactions in constituent nuclides of trinitrotoluene. This formula can be used for the efficient landmine detection of explosives in quantities as small as ~200 g of trinitrotoluene concealed at depths down to about 15 cm. The empirical formula can be embedded in a field programmable gate array on a field-portable explosives' sensor for efficient online detection.

  3. Beware the black box: investigating the sensitivity of FEA simulations to modelling factors in comparative biomechanics

    Christopher W. Walmsley

    2013-11-01

    Full Text Available Finite element analysis (FEA is a computational technique of growing popularity in the field of comparative biomechanics, and is an easily accessible platform for form-function analyses of biological structures. However, its rapid evolution in recent years from a novel approach to common practice demands some scrutiny in regards to the validity of results and the appropriateness of assumptions inherent in setting up simulations. Both validation and sensitivity analyses remain unexplored in many comparative analyses, and assumptions considered to be ‘reasonable’ are often assumed to have little influence on the results and their interpretation.Here we report an extensive sensitivity analysis where high resolution finite element (FE models of mandibles from seven species of crocodile were analysed under loads typical for comparative analysis: biting, shaking, and twisting. Simulations explored the effect on both the absolute response and the interspecies pattern of results to variations in commonly used input parameters. Our sensitivity analysis focuses on assumptions relating to the selection of material properties (heterogeneous or homogeneous, scaling (standardising volume, surface area, or length, tooth position (front, mid, or back tooth engagement, and linear load case (type of loading for each feeding type.Our findings show that in a comparative context, FE models are far less sensitive to the selection of material property values and scaling to either volume or surface area than they are to those assumptions relating to the functional aspects of the simulation, such as tooth position and linear load case. Results show a complex interaction between simulation assumptions, depending on the combination of assumptions and the overall shape of each specimen. Keeping assumptions consistent between models in an analysis does not ensure that results can be generalised beyond the specific set of assumptions used. Logically, different

  4. Uncertainty of Wheat Water Use: Simulated Patterns and Sensitivity to Temperature and CO2

    Cammarano, Davide; Roetter, Reimund P.; Asseng, Senthold; Ewert, Frank; Wallach, Daniel; Martre, Pierre; Hatfield, Jerry L.; Jones, James W.; Rosenzweig, Cynthia E.; Ruane, Alex C.; hide

    2016-01-01

    Projected global warming and population growth will reduce future water availability for agriculture. Thus, it is essential to increase the efficiency in using water to ensure crop productivity. Quantifying crop water use (WU; i.e. actual evapotranspiration) is a critical step towards this goal. Here, sixteen wheat simulation models were used to quantify sources of model uncertainty and to estimate the relative changes and variability between models for simulated WU, water use efficiency (WUE, WU per unit of grain dry mass produced), transpiration efficiency (Teff, transpiration per kg of unit of grain yield dry mass produced), grain yield, crop transpiration and soil evaporation at increased temperatures and elevated atmospheric carbon dioxide concentrations ([CO2]). The greatest uncertainty in simulating water use, potential evapotranspiration, crop transpiration and soil evaporation was due to differences in how crop transpiration was modelled and accounted for 50 of the total variability among models. The simulation results for the sensitivity to temperature indicated that crop WU will decline with increasing temperature due to reduced growing seasons. The uncertainties in simulated crop WU, and in particularly due to uncertainties in simulating crop transpiration, were greater under conditions of increased temperatures and with high temperatures in combination with elevated atmospheric [CO2] concentrations. Hence the simulation of crop WU, and in particularly crop transpiration under higher temperature, needs to be improved and evaluated with field measurements before models can be used to simulate climate change impacts on future crop water demand.

  5. Sonic profile simulation from the profiles of gamma ray and resistivity in the wells from Campos Basin

    Leite, Marcos; Carrasquilla, Abel; Silva, Jadir da

    2008-01-01

    The knowledge of the mechanical properties of the rocks is essential in the calculation of the stability of the oil wells and in the elaboration of drilling projects, because they help in the selection of the best equipment for each geologic scene. In these activities, the most important mechanical property is the rock compressibility, which can be calculated from the sonic geophysical log, but this one, not always available in the well data set. In order to minimize this limitation, it was developed, in this work, a methodology to simulate it through an algorithm that utilizes fuzzy logic concepts, using as input data gamma ray and resistivity logs. The basic principle of this methodology is to propose that any geophysical log, including the sonic log, can be considered function of other measured geophysical logs in the same depths. On the other hand, to test the confidence of this approach, it was compared with two others commonly used in the simulation of logs: the linear multiple regression and the neural network back-propagation, showing, our methodology, however, better results. Finally, to validate the method, it was tested using wells from Namorado Oil Field in Campos Basin, which contains gamma ray, sonic and resistivity logs. (author)

  6. Simulation of single-event energy-deposition spreading in a hybrid pixellated detector for gamma imaging

    Manach, E

    2002-01-01

    In the framework of the Medipix2 Collaboration, a new photon-counting chip is being developed made of a 256x256 array of 55 mu m-side square pixels. Although the chip was primarily developed for semiconductor X-ray imagers, we think that this type of device could be used in applications such as decommissioning of nuclear facilities where typical sources have gamma-ray energies in the range of a few hundred keV. In order to enhance the detection efficiency in this energy range, we envisage connecting the Medipix2 chip to a CdTe or CdZnTe substrate (at least 1 mm thick). The small pixel size, the thickness of the Cd(Zn)Te substrate and the high photon energy motivate us to estimate first the spatial energy spreading following a photon interaction inside the detector. Estimations were made using the MCNP Monte Carlo package by simulating the individual energy distribution for each primary photon interaction. As an illustration of our results, simulating a 660 keV gamma source, we found that there are two pixels ...

  7. Development of gamma-ray absorption and scattering simulation platform based on MCNP

    Lai Wanchang; Chen Henggui; Zhang Zhen; Chen Xiaoqiang

    2010-01-01

    It describes a γ-ray absorption and scattering simulation platform centering on MCNP, and developed corresponding accessories on the basis of the MCNP. Simulation of this simulation platform can be 93 kinds of single-quality materials and 2-3 kinds of multi-element mixture absorption experiment, simulating the absorption thickness of 0-100cm, and the thickness increment in 0.001cm. The media of Scattering Simulation is from the Li to the Am, the angle between the simulation measuring degree and incident ray direction is from-90 to 90, the angle in increments in 1 degree. (authors)

  8. Uncertainty quantification and sensitivity analysis with CASL Core Simulator VERA-CS

    Brown, C.S.; Zhang, Hongbin

    2016-01-01

    VERA-CS (Virtual Environment for Reactor Applications, Core Simulator) is a coupled neutron transport and thermal-hydraulics code under development by the Consortium for Advanced Simulation of Light Water Reactors (CASL). An approach to uncertainty quantification and sensitivity analysis with VERA-CS was developed and a new toolkit was created to perform uncertainty quantification and sensitivity analysis. A 2 × 2 fuel assembly model was developed and simulated by VERA-CS, and uncertainty quantification and sensitivity analysis were performed with fourteen uncertain input parameters. The minimum departure from nucleate boiling ratio (MDNBR), maximum fuel center-line temperature, and maximum outer clad surface temperature were chosen as the selected figures of merit. Pearson, Spearman, and partial correlation coefficients were considered for all of the figures of merit in sensitivity analysis and coolant inlet temperature was consistently the most influential parameter. Parameters used as inputs to the critical heat flux calculation with the W-3 correlation were shown to be the most influential on the MDNBR, maximum fuel center-line temperature, and maximum outer clad surface temperature.

  9. Sensitivity of simulated maize crop yields to regional climate in the Southwestern United States

    Kim, S.; Myoung, B.; Stack, D.; Kim, J.; Hatzopoulos, N.; Kafatos, M.

    2013-12-01

    The sensitivity of maize yield to the regional climate in the Southwestern United States (SW US) has been investigated by using a crop-yield simulation model (APSIM) in conjunction with meteorological forcings (daily minimum and maximum temperature, precipitation, and radiation) from the North American Regional Reanalysis (NARR) dataset. The primary focus of this study is to look at the effects of interannual variations of atmospheric components on the crop productivity in the SW US over the 21-year period (1991 to 2011). First of all, characteristics and performance of APSIM was examined by comparing simulated maize yields with observed yields from United States Department of Agriculture (USDA) and the leaf-area index (LAI) from MODIS satellite data. Comparisons of the simulated maize yield with the available observations show that the crop model can reasonably reproduce observed maize yields. Sensitivity tests were performed to assess the relative contribution of each climate driver to regional crop yield. Sensitivity experiments show that potential crop production responds nonlinearly to climate drivers and the yield sensitivity varied among geographical locations depending on their mean climates. Lastly, a detailed analysis of both the spatial and temporal variations of each climate driver in the regions where maize is actually grown in three states (CA, AZ, and NV) in the SW US was performed.

  10. Computer simulation of interstitial atom loop with vacancies in gamma-iron lattice

    Golubov, S.I.; Doronina, V.I.; Kaipetskaya, E.N.

    1985-01-01

    The interaction of vacanies and a dislocation loop has been investigated by the mashine stimulation method. The calculations have been performed by the variation method using the Jonson pair potential for gamma-iron. The interaction of a vacancy and a loop of interstitial atoms in the form of a regular hexagon has been investigated. The results obtained are compared with calculations in the elastic approximation

  11. Sensitivity analysis of the titan hybrid deterministic transport code for SPECT simulation

    Royston, Katherine K.; Haghighat, Alireza

    2011-01-01

    Single photon emission computed tomography (SPECT) has been traditionally simulated using Monte Carlo methods. The TITAN code is a hybrid deterministic transport code that has recently been applied to the simulation of a SPECT myocardial perfusion study. For modeling SPECT, the TITAN code uses a discrete ordinates method in the phantom region and a combined simplified ray-tracing algorithm with a fictitious angular quadrature technique to simulate the collimator and generate projection images. In this paper, we compare the results of an experiment with a physical phantom with predictions from the MCNP5 and TITAN codes. While the results of the two codes are in good agreement, they differ from the experimental data by ∼ 21%. In order to understand these large differences, we conduct a sensitivity study by examining the effect of different parameters including heart size, collimator position, collimator simulation parameter, and number of energy groups. (author)

  12. Empirically Derived and Simulated Sensitivity of Vegetation to Climate Across Global Gradients of Temperature and Precipitation

    Quetin, G. R.; Swann, A. L. S.

    2017-12-01

    Successfully predicting the state of vegetation in a novel environment is dependent on our process level understanding of the ecosystem and its interactions with the environment. We derive a global empirical map of the sensitivity of vegetation to climate using the response of satellite-observed greenness and leaf area to interannual variations in temperature and precipitation. Our analysis provides observations of ecosystem functioning; the vegetation interactions with the physical environment, across a wide range of climates and provide a functional constraint for hypotheses engendered in process-based models. We infer mechanisms constraining ecosystem functioning by contrasting how the observed and simulated sensitivity of vegetation to climate varies across climate space. Our analysis yields empirical evidence for multiple physical and biological mediators of the sensitivity of vegetation to climate as a systematic change across climate space. Our comparison of remote sensing-based vegetation sensitivity with modeled estimates provides evidence for which physiological mechanisms - photosynthetic efficiency, respiration, water supply, atmospheric water demand, and sunlight availability - dominate the ecosystem functioning in places with different climates. Earth system models are generally successful in reproducing the broad sign and shape of ecosystem functioning across climate space. However, this general agreement breaks down in hot wet climates where models simulate less leaf area during a warmer year, while observations show a mixed response but overall more leaf area during warmer years. In addition, simulated ecosystem interaction with temperature is generally larger and changes more rapidly across a gradient of temperature than is observed. We hypothesize that the amplified interaction and change are both due to a lack of adaptation and acclimation in simulations. This discrepancy with observations suggests that simulated responses of vegetation to

  13. Constraining Transient Climate Sensitivity Using Coupled Climate Model Simulations of Volcanic Eruptions

    Merlis, Timothy M.; Held, Isaac M.; Stenchikov, Georgiy L.; Zeng, Fanrong; Horowitz, Larry W.

    2014-01-01

    Coupled climate model simulations of volcanic eruptions and abrupt changes in CO2 concentration are compared in multiple realizations of the Geophysical Fluid Dynamics Laboratory Climate Model, version 2.1 (GFDL CM2.1). The change in global-mean surface temperature (GMST) is analyzed to determine whether a fast component of the climate sensitivity of relevance to the transient climate response (TCR; defined with the 1%yr-1 CO2-increase scenario) can be estimated from shorter-time-scale climate changes. The fast component of the climate sensitivity estimated from the response of the climate model to volcanic forcing is similar to that of the simulations forced by abrupt CO2 changes but is 5%-15% smaller than the TCR. In addition, the partition between the top-of-atmosphere radiative restoring and ocean heat uptake is similar across radiative forcing agents. The possible asymmetry between warming and cooling climate perturbations, which may affect the utility of volcanic eruptions for estimating the TCR, is assessed by comparing simulations of abrupt CO2 doubling to abrupt CO2 halving. There is slightly less (~5%) GMST change in 0.5 × CO2 simulations than in 2 × CO2 simulations on the short (~10 yr) time scales relevant to the fast component of the volcanic signal. However, inferring the TCR from volcanic eruptions is more sensitive to uncertainties from internal climate variability and the estimation procedure. The response of the GMST to volcanic eruptions is similar in GFDL CM2.1 and GFDL Climate Model, version 3 (CM3), even though the latter has a higher TCR associated with a multidecadal time scale in its response. This is consistent with the expectation that the fast component of the climate sensitivity inferred from volcanic eruptions is a lower bound for the TCR.

  14. Constraining Transient Climate Sensitivity Using Coupled Climate Model Simulations of Volcanic Eruptions

    Merlis, Timothy M.

    2014-10-01

    Coupled climate model simulations of volcanic eruptions and abrupt changes in CO2 concentration are compared in multiple realizations of the Geophysical Fluid Dynamics Laboratory Climate Model, version 2.1 (GFDL CM2.1). The change in global-mean surface temperature (GMST) is analyzed to determine whether a fast component of the climate sensitivity of relevance to the transient climate response (TCR; defined with the 1%yr-1 CO2-increase scenario) can be estimated from shorter-time-scale climate changes. The fast component of the climate sensitivity estimated from the response of the climate model to volcanic forcing is similar to that of the simulations forced by abrupt CO2 changes but is 5%-15% smaller than the TCR. In addition, the partition between the top-of-atmosphere radiative restoring and ocean heat uptake is similar across radiative forcing agents. The possible asymmetry between warming and cooling climate perturbations, which may affect the utility of volcanic eruptions for estimating the TCR, is assessed by comparing simulations of abrupt CO2 doubling to abrupt CO2 halving. There is slightly less (~5%) GMST change in 0.5 × CO2 simulations than in 2 × CO2 simulations on the short (~10 yr) time scales relevant to the fast component of the volcanic signal. However, inferring the TCR from volcanic eruptions is more sensitive to uncertainties from internal climate variability and the estimation procedure. The response of the GMST to volcanic eruptions is similar in GFDL CM2.1 and GFDL Climate Model, version 3 (CM3), even though the latter has a higher TCR associated with a multidecadal time scale in its response. This is consistent with the expectation that the fast component of the climate sensitivity inferred from volcanic eruptions is a lower bound for the TCR.

  15. Rifampicin sensitivity of residual RNA synthesis in Escherichia coli cells exposed to ultraviolet radiation and combined ultraviolet and. gamma. radiations

    Prakash, R K; Netrawali, M S; Pradhan, D S [Bhabha Atomic Research Centre, Bombay (India). Biochemistry and Food Technology Div.

    1976-09-01

    UV-irradiation prevents rifampicin inhibition of the initiation of RNA synthesis by E.coli cells, but such rifampicin insensitivity is not exhibited by the residual RNA synthesis in ..gamma..-irradiated cells. Studies of the rate of (/sup 3/H)-uridine incorporation by E.coli cells at various times of incubation have been used to show that when ..gamma.. irradiation was given either before or after uv-irradiation of cells, the observed rifampicin insensitivity of residual RNA synthesis in the uv-irradiated cells was obliterated. RNA synthesis in cells subjected to combined exposures of uv- and ..gamma..-radiations was lowered to a lesser extent than that in the cells exposed to uv-irradiation alone. Possible mechanisms are discussed.

  16. 3-d brownian motion simulator for high-sensitivity nanobiotechnological applications.

    Toth, Arpád; Banky, Dániel; Grolmusz, Vince

    2011-12-01

    A wide variety of nanobiotechnologic applications are being developed for nanoparticle based in vitro diagnostic and imaging systems. Some of these systems make possible highly sensitive detection of molecular biomarkers. Frequently, the very low concentration of the biomarkers makes impossible the classical, partial differential equation-based mathematical simulation of the motion of the nanoparticles involved. We present a three-dimensional Brownian motion simulation tool for the prediction of the movement of nanoparticles in various thermal, viscosity, and geometric settings in a rectangular cuvette. For nonprofit users the server is freely available at the site http://brownian.pitgroup.org.

  17. Skin sensitization: Modeling based on skin metabolism simulation and formation of protein conjugates

    Dimitrov, Sabcho; Low, Lawrence; Patlewicz, Grace

    2005-01-01

    alerting groups, three-dimensional (3D)-QSARs were developed to describe the multiplicity of physicochemical, steric, and electronic parameters. These 3D-QSARs, so-called pattern recognition-type models, were applied each time a latent alerting group was identified in a parent chemical or its generated...... in the model building. The TIssue MEtabolism Simulator (TIMES) software was used to integrate a skin metabolism simulator and 3D-QSARs to evaluate the reactivity of chemicals thus predicting their likely skin sensitization potency....

  18. A practical approach to the sensitivity analysis for kinetic Monte Carlo simulation of heterogeneous catalysis

    Hoffmann, Max J.; Engelmann, Felix; Matera, Sebastian

    2017-01-01

    Lattice kinetic Monte Carlo simulations have become a vital tool for predictive quality atomistic understanding of complex surface chemical reaction kinetics over a wide range of reaction conditions. In order to expand their practical value in terms of giving guidelines for the atomic level design of catalytic systems, it is very desirable to readily evaluate a sensitivity analysis for a given model. The result of such a sensitivity analysis quantitatively expresses the dependency of the turnover frequency, being the main output variable, on the rate constants entering the model. In the past, the application of sensitivity analysis, such as degree of rate control, has been hampered by its exuberant computational effort required to accurately sample numerical derivatives of a property that is obtained from a stochastic simulation method. In this study, we present an efficient and robust three-stage approach that is capable of reliably evaluating the sensitivity measures for stiff microkinetic models as we demonstrate using the CO oxidation on RuO2(110) as a prototypical reaction. In the first step, we utilize the Fisher information matrix for filtering out elementary processes which only yield negligible sensitivity. Then we employ an estimator based on the linear response theory for calculating the sensitivity measure for non-critical conditions which covers the majority of cases. Finally, we adapt a method for sampling coupled finite differences for evaluating the sensitivity measure for lattice based models. This allows for an efficient evaluation even in critical regions near a second order phase transition that are hitherto difficult to control. The combined approach leads to significant computational savings over straightforward numerical derivatives and should aid in accelerating the nano-scale design of heterogeneous catalysts.

  19. EVALUATING THE SENSITIVITY OF RADIONUCLIDE DETECTORS FOR CONDUCTING A MARITIME ON-BOARD SEARCH USING MONTE CARLO SIMULATION IMPLEMENTED IN AVERT(regsign)

    Harris, S.; Dave Dunn, D.

    2009-01-01

    The sensitivity of two specific types of radionuclide detectors for conducting an on-board search in the maritime environment was evaluated using Monte Carlo simulation implemented in AVERT(reg s ign). AVERT(reg s ign), short for the Automated Vulnerability Evaluation for Risk of Terrorism, is personal computer based vulnerability assessment software developed by the ARES Corporation. The sensitivity of two specific types of radionuclide detectors for conducting an on-board search in the maritime environment was evaluated using Monte Carlo simulation. The detectors, a RadPack and also a Personal Radiation Detector (PRD), were chosen from the class of Human Portable Radiation Detection Systems (HPRDS). Human Portable Radiation Detection Systems (HPRDS) serve multiple purposes. In the maritime environment, there is a need to detect, localize, characterize, and identify radiological/nuclear (RN) material or weapons. The RadPack is a commercially available broad-area search device used for gamma and also for neutron detection. The PRD is chiefly used as a personal radiation protection device. It is also used to detect contraband radionuclides and to localize radionuclide sources. Neither device has the capacity to characterize or identify radionuclides. The principal aim of this study was to investigate the sensitivity of both the RadPack and the PRD while being used under controlled conditions in a simulated maritime environment for detecting hidden RN contraband. The detection distance varies by the source strength and the shielding present. The characterization parameters of the source are not indicated in this report so the results summarized are relative. The Monte Carlo simulation results indicate the probability of detection of the RN source at certain distances from the detector which is a function of transverse speed and instrument sensitivity for the specified RN source

  20. Certain aspects of the sensitivity and mutability of two beans varieties under the influence of gamma-irradiation and EMS treatment

    Yankulov, M.T.; Isasi, E.; Abreu, S.

    1979-01-01

    The relation between sensitivity and mutability of some beans varieties after treatment of their seeds with different gamma-ray doses and ethyl methanesulphonate (EMS) and the changes in their mutagenic effect with increasing the dose were studied. Seleccion 11 and Bolita 41 varieties were used. Seed irradiation (humidity 8,5%) was carried out with doses of 7500, 12500 and 17500 rad gamma-rays. EMS solutions of 0.05, 0,10 and 0,15% at 20 0 C for 12 hours were applied. Records of the percentages of germination and survival were kept in M 1 generation. All seeds from survived plants were sown, and in M 2 the type and number of chlorophyll mutations were reported. Survival of either variety decreased with increasing the case of gamma rays or of EMS. Gamma radiation injury was more severe and occurred even with lower doses. Seleccion 11 variety proved to be more sensitive. The comparison between plant survival in M 1 and the percentage of chlorophyll mutations in M 2 shows an inverse relation between them, i.e. the decrease in the percentage of survived plants was accompanied by an increase in the percentage of chlorophyll mutations. At a certain survival percentage the percentage of induced chlorophyll mutations was of the same order, regardless of the mutagen factor used. When hybrid forms were treated the mutation frequency was higher than the one following treatment of parent forms. A study of the mutation frequency, depending on the dose of the mutagenic factor shows that there is only a limited possibility to raise the percentage of induced mutations by the effects of higher doses. (A.B.)

  1. 2D Numerical Simulation and Sensitive Analysis of H-Darrieus Wind Turbine

    Seyed Mohammad E. Saryazdi

    2018-02-01

    Full Text Available Recently, a lot of attention has been devoted to the use of Darrieus wind turbines in urban areas. The aerodynamics of a Darrieus turbine are very complex due to dynamic stall and changing forces on the turbine triggered by changing horizontal angles. In this study, the aerodynamics of H-rotor vertical axis wind turbine (VAWT has been studied using computational fluid dynamics via two different turbulence models. Shear stress transport (SST k-ω turbulence model was used to simulate a 2D unsteady model of the H-Darrieus turbine. In order to complete this simulation, sensitivity analysis of the effective turbine parameters such as solidity factor, airfoil shape, wind velocity and shaft diameter were done. To simulate the flow through the turbine, a 2D simplified computational domain has been generated. Then fine mesh for each case consisting of different turbulence models and dimensions has been generated. Each mesh in this simulation dependent on effective parameters consisted of domain size, mesh quality, time step and total revolution. The sliding mesh method was applied to evaluate the unsteady interaction between the stationary and rotating components. Previous works just simulated turbine, while in our study sensitivity analysis of effective parameters was done. The simulation results closely match the experimental data, providing an efficient and reliable foundation to study wind turbine aerodynamics. This also demonstrates computing the best value of the effective parameter. The sensitivity analysis revealed best value of the effective parameter that could be used in the process of designing turbine. This work provides the first step in developing an accurate 3D aerodynamic modeling of Darrieus wind turbines. Article History: Received :August 19th 2017; Received: December 15th 2017; Accepted: Januari 14th 2018; Available online How to Cite This Article: Saryazdi, S. M. E. and Boroushaki, M. (2018 2D Numerical Simulation and Sensitive

  2. Gamma ray energy loss spectra simulation in NaI detectors with the Monte Carlo method

    Vieira, W.J.

    1982-01-01

    With the aim of studying and applying the Monte Carlo method, a computer code was developed to calculate the pulse height spectra and detector efficiencies for gamma rays incident on NaI (Tl) crystals. The basic detector processes in NaI (Tl) detectors are given together with an outline of Monte Carlo methods and a general review of relevant published works. A detailed description of the application of Monte Carlo methods to ν-ray detection in NaI (Tl) detectors is given. Comparisons are made with published, calculated and experimental, data. (Author) [pt

  3. $\\gamma + \\phi_s$ sensitivity studies from combined $B_{s}^{0}\\to D_{s}^{-}\\pi^{+}$ and $B_{s}^{0}\\to D_{s}^{\\mp}K^{\\pm}$ samples at LHCb

    Cohen, S; Rodrigues, E

    2007-01-01

    At the LHCb experiment the decay channels $\\Bpiminus$ and $\\BKminusplus$ will be used to determine the physics parameters $\\dMs$ and $\\gamma + \\phi_s$. By performing toy Monte Carlo simulation studies, using information from a full GEANT LHCb simulation, we expect statistical uncertainties of $\\sigma(\\dMs)=0.007\\ps^{-1}$ and \\mbox{$\\sigma(\\gamma + \\phi_s)=10.3^{\\circ}$} for an integrated luminosity of $2\\fb^{-1}$.

  4. Gamma camera

    Schlosser, P.A.; Steidley, J.W.

    1980-01-01

    The design of a collimation system for a gamma camera for use in nuclear medicine is described. When used with a 2-dimensional position sensitive radiation detector, the novel system can produce superior images than conventional cameras. The optimal thickness and positions of the collimators are derived mathematically. (U.K.)

  5. Study of the heterogeneities effect in the dose distributions of Leksell Gamma Knife (R), through Monte Carlo simulation; Estudio del efecto de las heterogeneidades en las distribuciones de dosis del Leksell GammaKnife (R), mediante simulacion Monte Carlo

    Rojas C, E.L. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Al-Dweri, F.M.O.; Lallena R, A.M. [Universidad de Granada, Granada (Spain)]. e-mail: elrc@nuclear.inin.mx

    2005-07-01

    In this work they are studied, by means of Monte Carlo simulation, the effects that take place in the dose profiles that are obtained with the Leksell Gamma Knife (R), when they are kept in account heterogeneities. The considered heterogeneities simulate the skull and the spaces of air that are in the head, like they can be the nasal breasts or the auditory conduits. The calculations were made using the Monte Carlo Penelope simulation code (v. 2003). The geometry of each one of the 201 sources that this instrument is composed, as well as of the corresponding channels of collimation of the Gamma Knife (R), it was described by means of a simplified model of geometry that has been recently studied. The obtained results when they are kept in mind the heterogeneities they present non worthless differences regarding those obtained when those are not considered. These differences are maximum in the proximities of the interfaces among different materials. (Author)

  6. Studies on the sensitivity of guinea pigs and golden hamsters irradiated with different doses of gamma rays to infections with R and S forms of Pseudomonas pseudomallei

    Najdenski, Kh.M.; Velyanov, D.K.

    1989-01-01

    Whole-body gamma irradiation was carried out on guinea pigs of both sexes with 2 Gy (sublethal dose), 2 Gy fractionated (4 x 0.5 Gy a day) and 0.5 Gy, and on golden hamsters with 6 Gy (sublethal dose) and 0.5 Gy. The animals were injected i.p. 24 h after irradiation with bacterial suspensions of P. pseudomallei R 7 and R 15 . The results showed a great increase of sensitivity to infection in the animals irradiated with sublethal dose, both as regards the R and S forms. Susceptibility rose appreciably also in guinea pigs irradiated fractionally with a dose of 2 Gy and to a relatively lower degree upon irradiation with 0.5 Gy. For the golden hamsters the sensitivity toward both investigated strains was extremely high and it remained unchanged upon irradiation with 6 Gy and 0.5 Gy. The data obtained provided grounds for the existence of a certain correlation between the different radioresistance of guinea pigs and golden hamsters and the changes established in their sensitivity to infections with R and S forms of Ps. pseudomallei after whole-body gamma irradiation

  7. Steel billet reheat simulation with growth of oxide layer and investigation on zone temperature sensitivity

    Dubey, Satish Kumar; Srinivasan, P.

    2014-01-01

    This paper presents a three-dimensional heat conduction numerical model and simulation of steel billet reheating in a reheat furnace. The model considers the growth of oxide scale on the billet surfaces. Control-volume approach and implicit scheme of finite difference method are used to discretize the transient heat conduction equation. The model is validated with analytical results subject to limited conditions. Simulations are carried out for predictions of three-dimensional temperature filed in the billet and oxide scale growth on the billet surfaces. The model predictions are in agreement with expected trends. It was found that the effect of oxide scale on billet heating is considerable. In order to investigate the effect of zone temperatures on the responses, a parametric sensitivity subject to six responses of interest are carried out using analysis of mean approach. The simulation approach and parametric study presented will be useful and applicable to the steel industry.

  8. simulation effect of gamma radiation on growth and essential oil production of lemongrass cymbopogon citratus L

    Abo-Elseoud, M.A.; Deaf, M.N.; Afifi, R.A; Abo-Etia, A.M.

    2004-01-01

    field experiment was conducted to study the effect of different doses of gamma radiation on growth and volatile oil production of lemongrass, C ymbopogon citratus L. i n this consideration, lemongrass segments were exposed to irradiation doses of 0.5,10,20 and 40 gray and cultivated in the experimental field of atomic energy authority, Inshas. three consequent harvest were taken at flowering stage as the fresh weights were recorded . volatile oil contents, volatile oil constituents and sugars content were determined in the plants herb. results showed that irradiation doses up to 20 gray induced a stimulation effect on plant growth as it increased the fresh weight of plant herb. data of total oil content (cc/plant ) showed noticeable enhancement up to irradiation dose of 20 gray, however, a slight decline was recorded with the higher irradiation dose of 40 gray. GLC of lemongrass volatile oil revealed that 19 components are resulted as citral aa nd citral bw ere the most predominant components . the impact of the studied irradiation treatments on the constituents of lemongrass oil was discussed. in addition, sugars content were determined and some increases were resulted in response to the studied gamma irradiation treatments

  9. A Preliminary Study on Detecting Fake Gold Bars Using Prompt Gamma Activation Analysis: Simulation of Neutron Transmission in Gold Bar

    Lee, K. M.; Sun, G. M.

    2016-01-01

    The purpose of this study is to develop fake gold bar detecting method by using Prompt-gamma activation analysis (PGAA) facility at the Korea Atomic Energy Research Institute (KAERI). PGAA is an established nuclear analytical technique for non-destructive determination of elemental and isotopic compositions. For a preliminary study on detecting fake gold bar, Monte Carlo simulation of neutron transmission in gold bar was conducted and the possibility for detecting fake gold bar was confirmed. Under the gold bullion standard, it guaranteed the government would redeem any amount of currency for its value in gold. After the gold bullion standard ended, gold bars have been the target for investment as ever. But it is well known that fake gold bar exist in the gold market. This cannot be identified easily without performing a testing as it has the same appearance as the pure gold bar. In order to avoid the trading of fake gold bar in the market, they should be monitored thoroughly. Although the transmissivity of cold neutrons are low comparing that of thermal neutrons, the slower neutrons are more apt to be absorbed in a target, and can increase the prompt gamma emission rate. Also the flux of both thermal and cold neutron beam is high enough to activate thick target. If the neutron beam is irradiated on the front and the reverse side of gold bar, all insides of it can be detected

  10. A Preliminary Study on Detecting Fake Gold Bars Using Prompt Gamma Activation Analysis: Simulation of Neutron Transmission in Gold Bar

    Lee, K. M.; Sun, G. M. [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The purpose of this study is to develop fake gold bar detecting method by using Prompt-gamma activation analysis (PGAA) facility at the Korea Atomic Energy Research Institute (KAERI). PGAA is an established nuclear analytical technique for non-destructive determination of elemental and isotopic compositions. For a preliminary study on detecting fake gold bar, Monte Carlo simulation of neutron transmission in gold bar was conducted and the possibility for detecting fake gold bar was confirmed. Under the gold bullion standard, it guaranteed the government would redeem any amount of currency for its value in gold. After the gold bullion standard ended, gold bars have been the target for investment as ever. But it is well known that fake gold bar exist in the gold market. This cannot be identified easily without performing a testing as it has the same appearance as the pure gold bar. In order to avoid the trading of fake gold bar in the market, they should be monitored thoroughly. Although the transmissivity of cold neutrons are low comparing that of thermal neutrons, the slower neutrons are more apt to be absorbed in a target, and can increase the prompt gamma emission rate. Also the flux of both thermal and cold neutron beam is high enough to activate thick target. If the neutron beam is irradiated on the front and the reverse side of gold bar, all insides of it can be detected.

  11. Investigation of centers sensitive to S1-nuclease in the genoma of the yeast S. cerevisiae after in-vivo exposure to gamma radiation

    Geigl, E.M.

    1987-09-01

    The structure, distribution and repair of basal damage in DNS after exposure to 60 Co gamma radiation were investigated in S. cerevisiae cells. Small DNS regions with mispaired or unpaired bases of rather high stability were found whose rate of incidence and linear dose dependence appear to be similar to those of double strand breaks. In contrast to double strand breaks, they showed no statistical' distribution pattern across the genoma. Liquid holding experiments showed that centers sensitive to S1-nuclease will be repaired in S. cerevisiae by a combined process of recombination and postreplication repair; the gene products of the genes RAD50 and RAD18 are involved. (orig./AJ) [de

  12. Steady state likelihood ratio sensitivity analysis for stiff kinetic Monte Carlo simulations.

    Núñez, M; Vlachos, D G

    2015-01-28

    Kinetic Monte Carlo simulation is an integral tool in the study of complex physical phenomena present in applications ranging from heterogeneous catalysis to biological systems to crystal growth and atmospheric sciences. Sensitivity analysis is useful for identifying important parameters and rate-determining steps, but the finite-difference application of sensitivity analysis is computationally demanding. Techniques based on the likelihood ratio method reduce the computational cost of sensitivity analysis by obtaining all gradient information in a single run. However, we show that disparity in time scales of microscopic events, which is ubiquitous in real systems, introduces drastic statistical noise into derivative estimates for parameters affecting the fast events. In this work, the steady-state likelihood ratio sensitivity analysis is extended to singularly perturbed systems by invoking partial equilibration for fast reactions, that is, by working on the fast and slow manifolds of the chemistry. Derivatives on each time scale are computed independently and combined to the desired sensitivity coefficients to considerably reduce the noise in derivative estimates for stiff systems. The approach is demonstrated in an analytically solvable linear system.

  13. Bixin regulates mRNA expression involved in adipogenesis and enhances insulin sensitivity in 3T3-L1 adipocytes through PPAR{gamma} activation

    Takahashi, Nobuyuki; Goto, Tsuyoshi; Taimatsu, Aki; Egawa, Kahori; Katoh, Sota; Kusudo, Tatsuya; Sakamoto, Tomoya; Ohyane, Chie; Lee, Joo-Young; Kim, Young-il; Uemura, Taku; Hirai, Shizuka [Laboratory of Molecular Function of Food, Division of Food Science and Biotechnology, Graduate School of Agriculture, Kyoto University, Uji 611-0011 (Japan); Kawada, Teruo, E-mail: fat@kais.kyoto-u.ac.jp [Laboratory of Molecular Function of Food, Division of Food Science and Biotechnology, Graduate School of Agriculture, Kyoto University, Uji 611-0011 (Japan)

    2009-12-25

    Insulin resistance is partly due to suppression of insulin-induced glucose uptake into adipocytes. The uptake is dependent on adipocyte differentiation, which is controlled at mRNA transcription level. The peroxisome proliferator-activated receptor (PPAR), a ligand-regulated nuclear receptor, is involved in the differentiation. Many food-derived compounds serve as ligands to activate or inactivate PPAR. In this study, we demonstrated that bixin and norbixin (annatto extracts) activate PPAR{gamma} by luciferase reporter assay using GAL4-PPAR chimera proteins. To examine the effects of bixin on adipocytes, 3T3-L1 adipocytes were treated with bixin or norbixin. The treatment induced mRNA expression of PPAR{gamma} target genes such as adipocyte-specific fatty acid-binding protein (aP2), lipoprotein lipase (LPL), and adiponectin in differentiated 3T3-L1 adipocytes and enhanced insulin-dependent glucose uptake. The observations indicate that bixin acts as an agonist of PPAR{gamma} and enhances insulin sensitivity in 3T3-L1 adipocytes, suggesting that bixin is a valuable food-derived compound as a PPAR ligand to regulate lipid metabolism and to ameliorate metabolic syndrome.

  14. A 60-GHz interferometer with a local oscillator integrated antenna array for divertor simulation experiments on GAMMA 10/PDX

    Kohagura, J., E-mail: kohagura@prc.tsukuba.ac.jp; Yoshikawa, M.; Shima, Y.; Nojiri, K.; Sakamoto, M.; Nakashima, Y. [Plasma Research Center, University of Tsukuba, Tsukuba, Ibaraki 305-8577 (Japan); Wang, X. [Saitama University, Saitama 338-8570 (Japan); Kuwahara, D. [Tokyo University of Agriculture and Technology, Koganei, Tokyo 184-8588 (Japan); Ito, N. [National Institute of Technology, Ube College, Ube, Yamaguchi 755-8555 (Japan); Nagayama, Y. [National Institute of Fusion Science, Toki, Gifu 509-5292 (Japan); Mase, A. [Kyushu University, Kasuga, Fukuoka 816-8580 (Japan)

    2016-11-15

    In conventional multichannel/imaging microwave diagnostics of interferometry, reflectometry, and electron cyclotron emission measurements, a local oscillator (LO) signal is commonly supplied to a receiver array via irradiation using LO optics. In this work, we present a 60-GHz interferometer with a new eight-channel receiver array, called a local oscillator integrated antenna array (LIA). An outstanding feature of LIA is that it incorporates a frequency quadrupler integrated circuit for LO supply to each channel. This enables simple and uniform LO supply to the receiver array using only a 15-GHz LO source and a coaxial cable transmission line instead of using an expensive 60-GHz source, LO optics, and a waveguide transmission line. The new interferometer system is first applied to measure electron line-averaged density inside the divertor simulation experimental module (D-module) on GAMMA 10/PDX tandem mirror device.

  15. Four days of simulated shift work reduces insulin sensitivity in humans.

    Bescos, R; Boden, M J; Jackson, M L; Trewin, A J; Marin, E C; Levinger, I; Garnham, A; Hiam, D S; Falcao-Tebas, F; Conte, F; Owens, J A; Kennaway, D J; McConell, G K

    2018-06-01

    The aim of this study was to investigate the effects of 4 consecutive simulated night shifts on glucose homeostasis, mitochondrial function and central and peripheral rhythmicities compared with a simulated day shift schedule. Seventeen healthy adults (8M:9F) matched for sleep, physical activity and dietary/fat intake participated in this study (night shift work n = 9; day shift work n = 8). Glucose tolerance and insulin sensitivity before and after 4 nights of shift work were measured by an intravenous glucose tolerance test and a hyperinsulinaemic euglycaemic clamp respectively. Muscles biopsies were obtained to determine insulin signalling and mitochondrial function. Central and peripheral rhythmicities were assessed by measuring salivary melatonin and expression of circadian genes from hair samples respectively. Fasting plasma glucose increased (4.4 ± 0.1 vs. 4.6 ± 0.1 mmol L -1 ; P = .001) and insulin sensitivity decreased (25 ± 7%, P night shift, with no changes following the day shift. Night shift work had no effect on skeletal muscle protein expression (PGC1α, UCP3, TFAM and mitochondria Complex II-V) or insulin-stimulated pAkt Ser473, pTBC1D4Ser318 and pTBC1D4Thr642. Importantly, the metabolic changes after simulated night shifts occurred despite no changes in the timing of melatonin rhythmicity or hair follicle cell clock gene expression across the wake period (Per3, Per1, Nr1d1 and Nr1d2). Only 4 days of simulated night shift work in healthy adults is sufficient to reduce insulin sensitivity which would be expected to increase the risk of T2D. © 2018 Scandinavian Physiological Society. Published by John Wiley & Sons Ltd.

  16. The sensitivity of gamma-index method to the positioning errors of high-definition MLC in patient-specific VMAT QA for SBRT

    Kim, Jung-in; Park, So-Yeon; Kim, Hak Jae; Kim, Jin Ho; Ye, Sung-Joon; Park, Jong Min

    2014-01-01

    To investigate the sensitivity of various gamma criteria used in the gamma-index method for patient-specific volumetric modulated arc therapy (VMAT) quality assurance (QA) for stereotactic body radiation therapy (SBRT) using a flattening filter free (FFF) photon beam. Three types of intentional misalignments were introduced to original high-definition multi-leaf collimator (HD-MLC) plans. The first type, referred to Class Out, involved the opening of each bank of leaves. The second type, Class In, involved the closing of each bank of leaves. The third type, Class Shift, involved the shifting of each bank of leaves towards the ground. Patient-specific QAs for the original and the modified plans were performed with MapCHECK2 and EBT2 films. The sensitivity of the gamma-index method using criteria of 1%/1 mm, 1.5%/1.5 mm, 1%/2 mm, 2%/1 mm and 2%/2 mm was investigated with absolute passing rates according to the magnitudes of MLCs misalignments. In addition, the changes in dose-volumetric indicators due to the magnitudes of MLC misalignments were investigated. The correlations between passing rates and the changes in dose-volumetric indicators were also investigated using Spearman’s rank correlation coefficient (γ). The criterion of 2%/1 mm was able to detect Class Out and Class In MLC misalignments of 0.5 mm and Class Shift misalignments of 1 mm. The widely adopted clinical criterion of 2%/2 mm was not able to detect 0.5 mm MLC errors of the Class Out or Class In types, and also unable to detect 3 mm Class Shift errors. No correlations were observed between dose-volumetric changes and gamma passing rates (γ < 0.8). Gamma criterion of 2%/1 mm was found to be suitable as a tolerance level with passing rates of 90% and 80% for patient-specific VMAT QA for SBRT when using MapCHECK2 and EBT2 film, respectively

  17. Simulation study of the second-generation MR-compatible SPECT system based on the inverted compound-eye gamma camera design

    Lai, Xiaochun; Meng, Ling-Jian

    2018-02-01

    In this paper, we present simulation studies for the second-generation MRI compatible SPECT system, MRC-SPECT-II, based on an inverted compound eye (ICE) gamma camera concept. The MRC-SPECT-II system consists of a total of 1536 independent micro-pinhole-camera-elements (MCEs) distributed in a ring with an inner diameter of 6 cm. This system provides a FOV of 1 cm diameter and a peak geometrical efficiency of approximately 1.3% (the typical levels of 0.1%-0.01% found in modern pre-clinical SPECT instrumentations), while maintaining a sub-500 μm spatial resolution. Compared to the first-generation MRC-SPECT system (MRC-SPECT-I) (Cai 2014 Nucl. Instrum. Methods Phys. Res. A 734 147-51) developed in our lab, the MRC-SPECT-II system offers a similar resolution with dramatically improved sensitivity and greatly reduced physical dimension. The latter should allow the system to be placed inside most clinical and pre-clinical MRI scanners for high-performance simultaneous MRI and SPECT imaging.

  18. Sensitivity of CERES-Maize yield simulation to the selected weather data

    Zalud, Z.; Stastna, M.

    2000-01-01

    Sensitivity analysis of selected weather data runs after successful parametrization and validation of the CERES-Maize simulation model. Estimation of the potential yield has been carried out during the long term experiment (1980-1997) as well as the estimation of influence of meteorological parameters on the simulation results for the water-limited yield. 10 % under and over stimulation of global radiation and precipitation as well as increasing and decreasing temperature by 1 deg C on simulated potential and water-limited yield have been done. In most of the years, air temperature underestimation resulted in a higher simulated grain yield and overstimulation shown a lower yield for water limited level. Overestimation of precipitation during wet days in growing period of the maize leads to an increase of amount of water available for the plant and to increase the yield. Underestimation of global radiation by 10 % resulted in a decline in simulated grain yield from -8.8 to -9.9 %. The overestimation caused increase of the yield from 7.8 to 10 %. Overestimation by 10 % resulted in a slight underestimation of the yield in low yielding years and underestimation of global radiation by 10 % in overestimation of the yield. The effect was opposite in high yielding years

  19. Airfoil data sensitivity analysis for actuator disc simulations used in wind turbine applications

    Nilsson, Karl; Breton, Simon-Philippe; Ivanell, Stefan; Sørensen, Jens N

    2014-01-01

    To analyse the sensitivity of blade geometry and airfoil characteristics on the prediction of performance characteristics of wind farms, large-eddy simulations using an actuator disc (ACD) method are performed for three different blade/airfoil configurations. The aim of the study is to determine how the mean characteristics of wake flow, mean power production and thrust depend on the choice of airfoil data and blade geometry. In order to simulate realistic conditions, pre-generated turbulence and wind shear are imposed in the computational domain. Using three different turbulence intensities and varying the spacing between the turbines, the flow around 4-8 aligned turbines is simulated. The analysis is based on normalized mean streamwise velocity, turbulence intensity, relative mean power production and thrust. From the computations it can be concluded that the actual airfoil characteristics and blade geometry only are of importance at very low inflow turbulence. At realistic turbulence conditions for an atmospheric boundary layer the specific blade characteristics play an minor role on power performance and the resulting wake characteristics. The results therefore give a hint that the choice of airfoil data in ACD simulations is not crucial if the intention of the simulations is to compute mean wake characteristics using a turbulent inflow

  20. Numerical study on determining formation porosity using a boron capture gamma ray technique and MCNP.

    Liu, Juntao; Zhang, Feng; Wang, Xinguang; Han, Fei; Yuan, Zhelong

    2014-12-01

    Formation porosity can be determined using the boron capture gamma ray counting ratio with a near to far detector in a pulsed neutron-gamma element logging tool. The thermal neutron distribution, boron capture gamma spectroscopy and porosity response for formations with different water salinity and wellbore diameter characteristics were simulated using the Monte Carlo method. We found that a boron lining improves the signal-to-noise ratio and that the boron capture gamma ray counting ratio has a higher sensitivity for determining porosity than total capture gamma. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Radio-sensitivity analysis and selection of useful mutants of rape (Brassica napus L.) by gamma irradiation

    Goh, Eun Jeong; Kim, Wook Jin; Kim, Jin Baek; Kim, Dong Sub; Kim, Sang Hoon; Kang, Si Yong

    2010-01-01

    Rape (Brassica napus L.) plants are one of the major oilseed crops. The main components of rapeseed are oil (35 to 47%) and protein (15 to 32%). For the biodiesel production, the development of a new variety of rape plant with high biomass and/or oleic acid contents is required. In order to determine the optimum dose of gamma-ray irradiation, the rape seeds of cvs. Hanra (Hr), Youngsan (Ys), Tammi (Tm), and Tamra (Tr) were irradiated with a 100 ∼ 4,000 Gy dose range of gamma-rays. Considering the growth factors, the optimum doses were determined to be within the range of 600 ∼ 1,000 Gy for the selection of useful mutant lines. Six-hundred and eighty eight (688) M 2 mutant lines were obtained from 600 ∼ 1,000 Gy gamma-ray-irradiated M 1 plants through selfing. The growth characteristics, leaf shape, early flowering, and flower color were all investigated. The selected mutant numbers of early flowering, leaf shape, and flower color were 34, 52, and 3 from the four cultivars, respectively. These mutant lines will be used for the development of a new variety of rape plant with high biomass and oleic acid contents

  2. Sensitivity Characterization of Pressed Energetic Materials using Flyer Plate Mesoscale Simulations

    Rai, Nirmal; Udaykumar, H. S.

    Heterogeneous energetic materials like pressed explosives have complicated microstructure and contain various forms of heterogeneities such as pores, micro-cracks, energetic crystals etc. It is widely accepted that the presence of these heterogeneities can affect the sensitivity of these materials under shock load. The interaction of shock load with the microstructural heterogeneities may leads to the formation of local heated regions known as ``hot spots''. Chemical reaction may trigger at the hot spot regions depending on the hot spot temperature and the duration over which the temperature can be maintained before phenomenon like heat conduction, rarefaction waves withdraws energy from it. There are different mechanisms which can lead to the formation of hot spots including void collapse. The current work is focused towards the sensitivity characterization of two HMX based pressed energetic materials using flyer plate mesoscale simulations. The aim of the current work is to develop mesoscale numerical framework which can perform simulations by replicating the laboratory based flyer plate experiments. The current numerical framework uses an image processing approach to represent the microstructural heterogeneities incorporated in a massively parallel Eulerian code SCIMITAR3D. The chemical decomposition of HMX is modeled using Henson-Smilowitz reaction mechanism. The sensitivity characterization is aimed towards obtaining James initiation threshold curve and comparing it with the experimental results.

  3. Development of the GOSAT-2 FTS-2 Simulator and Preliminary Sensitivity Analysis for CO2 Retrieval

    Kamei, A.; Yoshida, Y.; Dupuy, E.; Hiraki, K.; Yokota, Y.; Oishi, Y.; Murakami, K.; Morino, I.; Matsunaga, T.

    2013-12-01

    The Greenhouse Gases Observing Satellite-2 (GOSAT-2), which is a successor mission to the GOSAT, is planned to be launched in FY 2017. The Fourier Transform Spectrometer-2 (FTS-2) onboard the GOSAT-2 is a primary sensor to observe infrared light reflected and emitted from the Earth's surface and atmosphere. The FTS-2 obtains high-spectral resolution spectra with four bands from near to short-wavelength infrared (SWIR) region and one band in the thermal infrared (TIR) region. The column amounts of carbon dioxide (CO2) and methane (CH4) are retrieved from the obtained radiance spectra with SWIR bands. Compared to the FTS onboard the GOSAT, the FTS-2 includes an additional SWIR band to allow for carbon monoxide (CO) measurement. We have been developing a tool, named GOSAT-2 FTS-2 simulator, which is capable of simulating the spectral radiance data observed by the FTS-2 using the Pstar2 radiative transfer code. The purpose of the GOSAT-2 FTS-2 simulator is to obtain data which is exploited in the sensor specification, the optimization of parameters for Level 1 processing, and the improvement of Level 2 algorithms. The GOSAT-2 FTS-2 simulator, composed of the six components: 1) Overall control, 2) Onboarding platform, 3) Spectral radiance calculation, 4) Fourier transform, 5) L1B processing, and 6) L1B data output, has been installed on the GOSAT Research Computation Facility (GOSAT RCF), which is a large-scale, high-performance, and energy-efficient computer. We present the progress in the development of the GOSAT-2 FTS-2 simulator and the preliminary sensitivity analysis, relating to the engineering parameters, the aerosols and clouds, and so on, on the Level 1 processing for CO2 retrieval from the obtained data by simulating the FTS-2 SWIR observation using the GOSAT-2 FTS-2 simulator.

  4. Using statistical sensitivities for adaptation of a best-estimate thermo-hydraulic simulation model

    Liu, X.J.; Kerner, A.; Schaefer, A.

    2010-01-01

    On-line adaptation of best-estimate simulations of NPP behaviour to time-dependent measurement data can be used to insure that simulations performed in parallel to plant operation develop synchronously with the real plant behaviour even over extended periods of time. This opens a range of applications including operator support in non-standard-situations, improving diagnostics and validation of measurements in real plants or experimental facilities. A number of adaptation methods have been proposed and successfully applied to control problems. However, these methods are difficult to be applied to best-estimate thermal-hydraulic codes, such as TRACE and ATHLET, with their large nonlinear differential equation systems and sophisticated time integration techniques. This paper presents techniques to use statistical sensitivity measures to overcome those problems by reducing the number of parameters subject to adaptation. It describes how to identify the most significant parameters for adaptation and how this information can be used by combining: -decomposition techniques splitting the system into a small set of component parts with clearly defined interfaces where boundary conditions can be derived from the measurement data, -filtering techniques to insure that the time frame for adaptation is meaningful, -numerical sensitivities to find minimal error conditions. The suitability of combining those techniques is shown by application to an adaptive simulation of the PKL experiment.

  5. Uncertainty and sensitivity analysis of control strategies using the benchmark simulation model No1 (BSM1).

    Flores-Alsina, Xavier; Rodriguez-Roda, Ignasi; Sin, Gürkan; Gernaey, Krist V

    2009-01-01

    The objective of this paper is to perform an uncertainty and sensitivity analysis of the predictions of the Benchmark Simulation Model (BSM) No. 1, when comparing four activated sludge control strategies. The Monte Carlo simulation technique is used to evaluate the uncertainty in the BSM1 predictions, considering the ASM1 bio-kinetic parameters and influent fractions as input uncertainties while the Effluent Quality Index (EQI) and the Operating Cost Index (OCI) are focused on as model outputs. The resulting Monte Carlo simulations are presented using descriptive statistics indicating the degree of uncertainty in the predicted EQI and OCI. Next, the Standard Regression Coefficients (SRC) method is used for sensitivity analysis to identify which input parameters influence the uncertainty in the EQI predictions the most. The results show that control strategies including an ammonium (S(NH)) controller reduce uncertainty in both overall pollution removal and effluent total Kjeldahl nitrogen. Also, control strategies with an external carbon source reduce the effluent nitrate (S(NO)) uncertainty increasing both their economical cost and variability as a trade-off. Finally, the maximum specific autotrophic growth rate (micro(A)) causes most of the variance in the effluent for all the evaluated control strategies. The influence of denitrification related parameters, e.g. eta(g) (anoxic growth rate correction factor) and eta(h) (anoxic hydrolysis rate correction factor), becomes less important when a S(NO) controller manipulating an external carbon source addition is implemented.

  6. Evaluation of spatial sensitivity of a prompt gamma neutron activation analysis facility for the in vivo determination of nitrogen in small animals

    Kasviki, K.; Ioannina University; Stamatelatos, I.E.; Kalef-Ezra, J.

    2007-01-01

    We investigated the spatial dependence of the sensitivity of nitrogen measurement with a prompt gamma neutron activation analysis (PGNAA) system for small animals and developed an analysis procedure that permits the reduction of systematic errors due to that dependence. The analysis procedure is based on neutron and photon transport calculations performed using the MCNP code in order to evaluate the sensitivity of the PGNAA facility. The system can be calibrated experimentally using a small number of phantoms of known size and composition. The calculation approach can then be used to predict responses for animal body sizes and shapes relatively to those experimentally determined and to include the effect of tissue inhomogeneities. Our calculations were verified by experimental measurements performed for a set of cylindrical inhomogeneous phantoms. The calculated to experimental ratios observed were within 6%. (author)

  7. [Parameter sensitivity of simulating net primary productivity of Larix olgensis forest based on BIOME-BGC model].

    He, Li-hong; Wang, Hai-yan; Lei, Xiang-dong

    2016-02-01

    Model based on vegetation ecophysiological process contains many parameters, and reasonable parameter values will greatly improve simulation ability. Sensitivity analysis, as an important method to screen out the sensitive parameters, can comprehensively analyze how model parameters affect the simulation results. In this paper, we conducted parameter sensitivity analysis of BIOME-BGC model with a case study of simulating net primary productivity (NPP) of Larix olgensis forest in Wangqing, Jilin Province. First, with the contrastive analysis between field measurement data and the simulation results, we tested the BIOME-BGC model' s capability of simulating the NPP of L. olgensis forest. Then, Morris and EFAST sensitivity methods were used to screen the sensitive parameters that had strong influence on NPP. On this basis, we also quantitatively estimated the sensitivity of the screened parameters, and calculated the global, the first-order and the second-order sensitivity indices. The results showed that the BIOME-BGC model could well simulate the NPP of L. olgensis forest in the sample plot. The Morris sensitivity method provided a reliable parameter sensitivity analysis result under the condition of a relatively small sample size. The EFAST sensitivity method could quantitatively measure the impact of simulation result of a single parameter as well as the interaction between the parameters in BIOME-BGC model. The influential sensitive parameters for L. olgensis forest NPP were new stem carbon to new leaf carbon allocation and leaf carbon to nitrogen ratio, the effect of their interaction was significantly greater than the other parameter' teraction effect.

  8. Simulating Metabolite Basis Sets for in vivo MRS Quantification; Incorporating details of the PRESS Pulse Sequence by means of the GAMMA C++ library

    Van der Veen, J.W.; Van Ormondt, D.; De Beer, R.

    2012-01-01

    In this work we report on generating/using simulated metabolite basis sets for the quantification of in vivo MRS signals, assuming that they have been acquired by using the PRESS pulse sequence. To that end we have employed the classes and functions of the GAMMA C++ library. By using several

  9. Spectral optimization simulation of white light based on the photopic eye-sensitivity curve

    Dai, Qi, E-mail: qidai@tongji.edu.cn [College of Architecture and Urban Planning, Tongji University, 1239 Siping Road, Shanghai 200092 (China); Institute for Advanced Study, Tongji University, 1239 Siping Road, Shanghai 200092 (China); Key Laboratory of Ecology and Energy-saving Study of Dense Habitat (Tongji University), Ministry of Education, 1239 Siping Road, Shanghai 200092 (China); Hao, Luoxi; Lin, Yi; Cui, Zhe [College of Architecture and Urban Planning, Tongji University, 1239 Siping Road, Shanghai 200092 (China); Key Laboratory of Ecology and Energy-saving Study of Dense Habitat (Tongji University), Ministry of Education, 1239 Siping Road, Shanghai 200092 (China)

    2016-02-07

    Spectral optimization simulation of white light is studied to boost maximum attainable luminous efficacy of radiation at high color-rendering index (CRI) and various color temperatures. The photopic eye-sensitivity curve V(λ) is utilized as the dominant portion of white light spectra. Emission spectra of a blue InGaN light-emitting diode (LED) and a red AlInGaP LED are added to the spectrum of V(λ) to match white color coordinates. It is demonstrated that at the condition of color temperature from 2500 K to 6500 K and CRI above 90, such white sources can achieve spectral efficacy of 330–390 lm/W, which is higher than the previously reported theoretical maximum values. We show that this eye-sensitivity-based approach also has advantages on component energy conversion efficiency compared with previously reported optimization solutions.

  10. Spectral optimization simulation of white light based on the photopic eye-sensitivity curve

    Dai, Qi; Hao, Luoxi; Lin, Yi; Cui, Zhe

    2016-01-01

    Spectral optimization simulation of white light is studied to boost maximum attainable luminous efficacy of radiation at high color-rendering index (CRI) and various color temperatures. The photopic eye-sensitivity curve V(λ) is utilized as the dominant portion of white light spectra. Emission spectra of a blue InGaN light-emitting diode (LED) and a red AlInGaP LED are added to the spectrum of V(λ) to match white color coordinates. It is demonstrated that at the condition of color temperature from 2500 K to 6500 K and CRI above 90, such white sources can achieve spectral efficacy of 330–390 lm/W, which is higher than the previously reported theoretical maximum values. We show that this eye-sensitivity-based approach also has advantages on component energy conversion efficiency compared with previously reported optimization solutions

  11. Stand-alone core sensitivity and uncertainty analysis of ALFRED from Monte Carlo simulations

    Pérez-Valseca, A.-D.; Espinosa-Paredes, G.; François, J.L.; Vázquez Rodríguez, A.; Martín-del-Campo, C.

    2017-01-01

    Highlights: • Methodology based on Monte Carlo simulation. • Sensitivity analysis of Lead Fast Reactor (LFR). • Uncertainty and regression analysis of LFR. • 10% change in the core inlet flow, the response in thermal power change is 0.58%. • 2.5% change in the inlet lead temperature the response is 1.87% in power. - Abstract: The aim of this paper is the sensitivity and uncertainty analysis of a Lead-Cooled Fast Reactor (LFR) based on Monte Carlo simulation of sizes up to 2000. The methodology developed in this work considers the uncertainty of sensitivities and uncertainty of output variables due to a single-input-variable variation. The Advanced Lead fast Reactor European Demonstrator (ALFRED) is analyzed to determine the behavior of the essential parameters due to effects of mass flow and temperature of liquid lead. The ALFRED core mathematical model developed in this work is fully transient, which takes into account the heat transfer in an annular fuel pellet design, the thermo-fluid in the core, and the neutronic processes, which are modeled with point kinetic with feedback fuel temperature and expansion effects. The sensitivity evaluated in terms of the relative standard deviation (RSD) showed that for 10% change in the core inlet flow, the response in thermal power change is 0.58%, and for 2.5% change in the inlet lead temperature is 1.87%. The regression analysis with mass flow rate as the predictor variable showed statistically valid cubic correlations for neutron flux and linear relationship neutron flux as a function of the lead temperature. No statistically valid correlation was observed for the reactivity as a function of the mass flow rate and for the lead temperature. These correlations are useful for the study, analysis, and design of any LFR.

  12. Sensitivity Analysis and Uncertainty Quantification for the LAMMPS Molecular Dynamics Simulation Code

    Picard, Richard Roy [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Bhat, Kabekode Ghanasham [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-07-18

    We examine sensitivity analysis and uncertainty quantification for molecular dynamics simulation. Extreme (large or small) output values for the LAMMPS code often occur at the boundaries of input regions, and uncertainties in those boundary values are overlooked by common SA methods. Similarly, input values for which code outputs are consistent with calibration data can also occur near boundaries. Upon applying approaches in the literature for imprecise probabilities (IPs), much more realistic results are obtained than for the complacent application of standard SA and code calibration.

  13. SU-F-T-62: Three-Dimensional Dosimetric Gamma Analysis for Impacts of Tissue Inhomogeneity Using Monte Carlo Simulation in Intracavitary Brachytheray for Cervix Carcinoma

    Nguyen, Tran Thi Thao; Nakamoto, Takahiro; Shibayama, Yusuke [Graduate School of Medical Sciences, Kyushu University (Japan); Arimura, Hidetaka [Faculty of Medical Sciences, Kyushu University (Japan); Oku, Yoshifumi [Kagoshima University Hospital (Japan); Yoshiura, Takashi [Graduate School of Diagnostic Radiotherapy, Kagoshima University (Japan)

    2016-06-15

    Purpose: The aim of this study was to investigate the impacts of tissue inhomogeneity on dose distributions using a three-dimensional (3D) gamma analysis in cervical intracavitary brachytherapy using Monte Carlo (MC) simulations. Methods: MC simulations for comparison of dose calculations were performed in a water phantom and a series of CT images of a cervical cancer patient (stage: Ib; age: 27) by employing a MC code, Particle and Heavy Ion Transport Code System (PHIT) version 2.73. The {sup 192}Ir source was set at fifteen dwell positions, according to clinical practice, in an applicator consisting of a tandem and two ovoids. Dosimetric comparisons were performed for the dose distributions in the water phantom and CT images by using gamma index image and gamma pass rate (%). The gamma index is the minimum Euclidean distance between two 3D spatial dose distributions of the water phantom and CT images in a same space. The gamma pass rates (%) indicate the percentage of agreement points, which mean that two dose distributions are similar, within an acceptance criteria (3 mm/3%). The volumes of physical and clinical interests for the gamma analysis were a whole calculated volume and a region larger than t% of a dose (close to a target), respectively. Results: The gamma pass rates were 77.1% for a whole calculated volume and 92.1% for a region within 1% dose region. The differences of 7.7% to 22.9 % between two dose distributions in the water phantom and CT images were found around the applicator region and near the target. Conclusion: This work revealed the large difference on the dose distributions near the target in the presence of the tissue inhomogeneity. Therefore, the tissue inhomogeneity should be corrected in the dose calculation for clinical treatment.

  14. Sensitivity of tumor motion simulation accuracy to lung biomechanical modeling approaches and parameters.

    Tehrani, Joubin Nasehi; Yang, Yin; Werner, Rene; Lu, Wei; Low, Daniel; Guo, Xiaohu; Wang, Jing

    2015-11-21

    Finite element analysis (FEA)-based biomechanical modeling can be used to predict lung respiratory motion. In this technique, elastic models and biomechanical parameters are two important factors that determine modeling accuracy. We systematically evaluated the effects of lung and lung tumor biomechanical modeling approaches and related parameters to improve the accuracy of motion simulation of lung tumor center of mass (TCM) displacements. Experiments were conducted with four-dimensional computed tomography (4D-CT). A Quasi-Newton FEA was performed to simulate lung and related tumor displacements between end-expiration (phase 50%) and other respiration phases (0%, 10%, 20%, 30%, and 40%). Both linear isotropic and non-linear hyperelastic materials, including the neo-Hookean compressible and uncoupled Mooney-Rivlin models, were used to create a finite element model (FEM) of lung and tumors. Lung surface displacement vector fields (SDVFs) were obtained by registering the 50% phase CT to other respiration phases, using the non-rigid demons registration algorithm. The obtained SDVFs were used as lung surface displacement boundary conditions in FEM. The sensitivity of TCM displacement to lung and tumor biomechanical parameters was assessed in eight patients for all three models. Patient-specific optimal parameters were estimated by minimizing the TCM motion simulation errors between phase 50% and phase 0%. The uncoupled Mooney-Rivlin material model showed the highest TCM motion simulation accuracy. The average TCM motion simulation absolute errors for the Mooney-Rivlin material model along left-right, anterior-posterior, and superior-inferior directions were 0.80 mm, 0.86 mm, and 1.51 mm, respectively. The proposed strategy provides a reliable method to estimate patient-specific biomechanical parameters in FEM for lung tumor motion simulation.

  15. Sensitivity of tumor motion simulation accuracy to lung biomechanical modeling approaches and parameters

    Tehrani, Joubin Nasehi; Wang, Jing; Yang, Yin; Werner, Rene; Lu, Wei; Low, Daniel; Guo, Xiaohu

    2015-01-01

    Finite element analysis (FEA)-based biomechanical modeling can be used to predict lung respiratory motion. In this technique, elastic models and biomechanical parameters are two important factors that determine modeling accuracy. We systematically evaluated the effects of lung and lung tumor biomechanical modeling approaches and related parameters to improve the accuracy of motion simulation of lung tumor center of mass (TCM) displacements. Experiments were conducted with four-dimensional computed tomography (4D-CT). A Quasi-Newton FEA was performed to simulate lung and related tumor displacements between end-expiration (phase 50%) and other respiration phases (0%, 10%, 20%, 30%, and 40%). Both linear isotropic and non-linear hyperelastic materials, including the neo-Hookean compressible and uncoupled Mooney–Rivlin models, were used to create a finite element model (FEM) of lung and tumors. Lung surface displacement vector fields (SDVFs) were obtained by registering the 50% phase CT to other respiration phases, using the non-rigid demons registration algorithm. The obtained SDVFs were used as lung surface displacement boundary conditions in FEM. The sensitivity of TCM displacement to lung and tumor biomechanical parameters was assessed in eight patients for all three models. Patient-specific optimal parameters were estimated by minimizing the TCM motion simulation errors between phase 50% and phase 0%. The uncoupled Mooney–Rivlin material model showed the highest TCM motion simulation accuracy. The average TCM motion simulation absolute errors for the Mooney–Rivlin material model along left-right, anterior–posterior, and superior–inferior directions were 0.80 mm, 0.86 mm, and 1.51 mm, respectively. The proposed strategy provides a reliable method to estimate patient-specific biomechanical parameters in FEM for lung tumor motion simulation. (paper)

  16. Sensitivity of tropical convection in cloud-resolving WRF simulations to model physics and forcing procedures

    Endo, S.; Lin, W.; Jackson, R. C.; Collis, S. M.; Vogelmann, A. M.; Wang, D.; Oue, M.; Kollias, P.

    2017-12-01

    Tropical convection is one of the main drivers of the climate system and recognized as a major source of uncertainty in climate models. High-resolution modeling is performed with a focus on the deep convection cases during the active monsoon period of the TWP-ICE field campaign to explore ways to improve the fidelity of convection permitting tropical simulations. Cloud resolving model (CRM) simulations are performed with WRF modified to apply flexible configurations for LES/CRM simulations. We have enhanced the capability of the forcing module to test different implementations of large-scale vertical advective forcing, including a function for optional use of large-scale thermodynamic profiles and a function for the condensate advection. The baseline 3D CRM configurations are, following Fridlind et al. (2012), driven by observationally-constrained ARM forcing and tested with diagnosed surface fluxes and fixed sea-surface temperature and prescribed aerosol size distributions. After the spin-up period, the simulations follow the observed precipitation peaks associated with the passages of precipitation systems. Preliminary analysis shows that the simulation is generally not sensitive to the treatment of the large-scale vertical advection of heat and moisture, while more noticeable changes in the peak precipitation rate are produced when thermodynamic profiles above the boundary layer were nudged to the reference profiles from the forcing dataset. The presentation will explore comparisons with observationally-based metrics associated with convective characteristics and examine the model performance with a focus on model physics, doubly-periodic vs. nested configurations, and different forcing procedures/sources. A radar simulator will be used to understand possible uncertainties in radar-based retrievals of convection properties. Fridlind, A. M., et al. (2012), A comparison of TWP-ICE observational data with cloud-resolving model results, J. Geophys. Res., 117, D05204

  17. Simulated sensitivity of African terrestrial ecosystem photosynthesis to rainfall frequency, intensity, and rainy season length

    Guan, Kaiyu; Good, Stephen P.; Caylor, Kelly K.; Medvigy, David; Pan, Ming; Wood, Eric F.; Sato, Hisashi; Biasutti, Michela; Chen, Min; Ahlström, Anders; Xu, Xiangtao

    2018-02-01

    There is growing evidence of ongoing changes in the statistics of intra-seasonal rainfall variability over large parts of the world. Changes in annual total rainfall may arise from shifts, either singly or in a combination, of distinctive intra-seasonal characteristics -i.e. rainfall frequency, rainfall intensity, and rainfall seasonality. Understanding how various ecosystems respond to the changes in intra-seasonal rainfall characteristics is critical for predictions of future biome shifts and ecosystem services under climate change, especially for arid and semi-arid ecosystems. Here, we use an advanced dynamic vegetation model (SEIB-DGVM) coupled with a stochastic rainfall/weather simulator to answer the following question: how does the productivity of ecosystems respond to a given percentage change in the total seasonal rainfall that is realized by varying only one of the three rainfall characteristics (rainfall frequency, intensity, and rainy season length)? We conducted ensemble simulations for continental Africa for a realistic range of changes (-20% ~ +20%) in total rainfall amount. We find that the simulated ecosystem productivity (measured by gross primary production, GPP) shows distinctive responses to the intra-seasonal rainfall characteristics. Specifically, increase in rainfall frequency can lead to 28% more GPP increase than the same percentage increase in rainfall intensity; in tropical woodlands, GPP sensitivity to changes in rainy season length is ~4 times larger than to the same percentage changes in rainfall frequency or intensity. In contrast, shifts in the simulated biome distribution are much less sensitive to intra-seasonal rainfall characteristics than they are to total rainfall amount. Our results reveal three major distinctive productivity responses to seasonal rainfall variability—‘chronic water stress’, ‘acute water stress’ and ‘minimum water stress’ - which are respectively associated with three broad spatial patterns of

  18. A rule based method for context sensitive threshold segmentation in SPECT using simulation

    Fleming, John S.; Alaamer, Abdulaziz S.

    1998-01-01

    Robust techniques for automatic or semi-automatic segmentation of objects in single photon emission computed tomography (SPECT) are still the subject of development. This paper describes a threshold based method which uses empirical rules derived from analysis of computer simulated images of a large number of objects. The use of simulation allowed the factors affecting the threshold which correctly segmented objects to be investigated systematically. Rules could then be derived from these data to define the threshold in any particular context. The technique operated iteratively and calculated local context sensitive thresholds along radial profiles from the centre of gravity of the object. It was evaluated in a further series of simulated objects and in human studies, and compared to the use of a global fixed threshold. The method was capable of improving accuracy of segmentation and volume assessment compared to the global threshold technique. The improvements were greater for small volumes, shapes with large surface area to volume ratio, variable surrounding activity and non-uniform distributions. The method was applied successfully to simulated objects and human studies and is considered to be a significant advance on global fixed threshold techniques. (author)

  19. A Study on a Solar Simulator for Dye Sensitized Solar Cells

    Kyoung-Jun Lee

    2012-01-01

    Full Text Available Dye-sensitized solar cells (DSSC are emerging low-cost, simple alternatives to conventional solar cells. While there has been considerable study on improving the efficiency of DSSCs, there has not been sufficient research on a photovoltaic power conditioning system adaptable to DSSCs or on a solar simulator for DSSCs. When DSSCs are commercialized in the near future, the DSSC modules must be connected to an adaptable power conditioning system in order to manage the energy produced and provide a suitable interface to the load. In the process of developing a power conditioning system, a solar simulator with the characteristics of DSSCs is essential to show the performance of the maximum power point tracking. In this paper, a virtual DSSC is designed and simulated in PSIM. Irradiation factors, temperature and shadow effects are considered in dynamic link library block in PSIM which is linked to the external C routine. A 100 W converter is built to show the performance of a DSSC as the solar simulator controlled by a digital signal processor.

  20. New model for assessing dose and dose rate sensitivity of Gamma ray radiation loss in polarization maintaining optical fibers

    Zhang Hongchen; Liu Hai; Qiao Wenqiang; Xue Huijie; He Shiyu

    2012-01-01

    Highlights: ► Building a new phenomenological theory model to investigate the relation about the irradiation induced loss with irradiation dose and dose rate. ► The Gamma ray irradiation induced loss of the “Capsule” type and “Panda” type polarization maintaining optical fibers at 1310 nm wavelength are investigated. ► The anti irradiation performance of the “Panda” type polarization maintaining optical fiber is better than that of the “Capsule” type polarization maintaining optical fiber, the reason is that the stress region doped by GeO 2 . - Abstract: The Gamma ray irradiation induced loss of the “Capsule” type and “Panda” type polarization maintaining optical fibers at 1310 nm wavelength are investigated. A phenomenological theory model is introduced and the influence of irradiation dose and dose rate on the irradiation induced loss is discussed. The phenomenological theoretical results are consistent with the experimental results of the irradiation induced loss for the two types of polarization maintaining optical fibers. The anti irradiation performance of the “Panda” type polarization maintaining optical fiber is better than that of the “Capsule” type polarization maintaining optical fiber, the reason is that the stress region dope with GeO 2 . Meanwhile, both of the polarization maintaining optical fiber irradiation induced loss increase with increasing the irradiation dose. In the case of same dose, the high dose rate Gamma ray irradiation induced optical fiber losses are higher than that of the low dose rate.

  1. Proposal of balloon and satellite observations of MeV gammas using Electron Tracking Compton Camera for reaching a high sensitivity of 1 mCrab

    Takada, Atsushi; Tanimori, Toru

    2016-04-01

    ETCC with a gas Time Projection Chamber (TPC) and pixel GSO scintillators, by measuring electron tracks precisely, provides both a strong background rejection by dE/dx of the track and well-defined 2-dimensional Point Spread Function (PDF) with better than several degrees by adding the arc direction of incident gammas (SPD: Scatter Plane Deviation) with the ARM (angular Resolution Measure) direction measured in standard Compton Camera (CC). In 2006 its background rejection was revealed by SMILE-I balloon experiment with 10cm-cubic ETCC using the dE/dx of tracks. In 2013, 30cm-cube-ETCC has been developed to catch gammas from Crab in next SMILE-II balloon with >5sigma detection for 4 hrs. Now its sensitivity has been improved to 10sigma by attaining the angular resolution of the track (SPD angle) to that determined by multiple scattering of the gas. Thus, we show the ability of ETCC to give a better significance by a factor of 10 than that of standard CCs having same detection area by electron tracking?and we have found that SPD is an essential to define the PSF of Compton imaging quantitatively. Such a well-defined PSF is, for the first time, able to provide reliable sensitivity in Compton imaging without assuming the use of optimization algorithm. These studies uncover the uncertainties of CCs from both points of view of the intense background and the difficulty of the definition of the PSF, and overcome the above problems. Based on this technology, SMILE-II with 3atm CF4 gas is expected to provide a 5times better sensitivity than COMPTEL in one month balloon, and 4modules of 50cm-cube ETCCs would exceed over 10^-12 erg/cm^2s^1 (1mCrab) in satellite. Here we summarize the performance of the ETCC and new astrophysics opened in near future by high sensitive observation of MeV gamma-rays.

  2. Effect of gamma irradiation on the life span of Drosophila melanogaster (Demonstration of threshold and sexual sensitivity differences)

    Giess, M.-C.; Planel, H.

    1977-01-01

    Drosophila melanogaster is irradiated by 5 to 75 krads of 60 Co gamma radiation at a dose rate of 1,000 rads/mn, on the fourth day of its imaginal life. As a result, the life span of the flies is reduced for both sexes. However, females are more radiosensitive than males. On the other hand, the radiosensitivity threshold in females is lower than in males: a life span decrease starts in males at a dose of 10 krads and at a dose of 25 krads in females [fr

  3. Geant4 simulation of continuum gamma spectroscopy with GAMMASPHERE and the SPINSPECTROMETER

    Silva, Z.; Ferrer, M.; Cristancho, F.

    2007-01-01

    The use of the so called Hk-technique (γ-energy sum and multiplicity data) is checked with simulations of the multi-detector γ-arrays GAMMASPHERE and SPINSPECTROMETER. Their response to typical γ-cascades is obtained and compared

  4. Measurements and simulations of the responses of the cluster Ge detectors to gamma rays

    Hara, Kaoru Y.; Goko, Shinji; Harada, Hideo; Hirose, Kentaro; Kimura, Atsushi; Kin, Tadahiro; Kitatani, Fumito; Koizumi, Mitsuo; Nakamura, Shoji; Toh, Yosuke

    2013-01-01

    Responses of cluster Ge detectors have been measured with standard γ-ray sources and the 35 Cl(n,γ) 36 Cl reaction in ANNRI at J-PARC/MLF. Experimental results and simulations using the EGS5 code are compared. (author)

  5. Low Doses of Gamma Rays Reduce the Sensitivity of Cervical Carcinoma Cells to Subsequent Treatment with Cisplatin

    Osmak, M.; Brozovic, A.

    2003-01-01

    One of the major challenges of modern genetics is to apply recent advances in mutation research to improve the accuracy of the estimates of the genetic risk for humans. Because of the important implications for radiation protection, biological effects of low-dose radiation have been a focus of research in recent years. Previously we have found that human cervical carcinoma HeLa cells irradiated repeatedly with low doses of gamma rays (HeLa1500 cells) became resistant to cisplatin. In this study we examine whether this effect was caused by inhibition of apoptosis. In HeLa and HeLa1500 cells we determined the induction of apoptosis following the treatment with cisplatin (i) by counting apoptotic cells with characteristic morphological changes, (ii) by analysing the expression of apoptotic genes involved in cytochrome c/Apaf-1/caspase-9 and in Fas/FasL pathways by Western blot method, and (iii) by estimating the activities of caspases by commercial caspase detection kits. Our results show that low doses of gamma rays induced alterations in human cervical carcinoma cells that were reflected in inhibition of p53-independent cisplatin-induced apoptosis due to reduced activity of caspase 3. (author)

  6. Simulated sensitivity of tropical cyclone track to the moisture in an idealized monsoon gyre

    Yan, Ziyu; Ge, Xuyang; Guo, Bingyao

    2017-12-01

    In this study, the sensitivity of tropical cyclone (TC) track to the moisture condition in a nearby monsoon gyre (MG) is investigated. Numerical simulations reveal that TC track is highly sensitive to the spatial distribution of relative humidity (RH). In an experiment conducted with higher (lower) RH in the eastern (western) semicircle of an MG, the TC experiences a sharp northward turning. In contrast, when the RH pattern is reversed, the simulated TC does not show a sharp northward turning. The RH distribution modulates the intensity and structure of both the TC and MG, so that when the TC is initially embedded in a moister environment, convection is enhanced in the outer core, which favors an expansion of the outer core size. A TC with a larger outer size has greater beta-effect propagation, favoring a faster westward translational speed. Meanwhile, higher RH enhances the vorticity gradient within the MG and promotes a quicker attraction between the TC and MG centers through vorticity segregation process. These cumulative effects cause the TC to collocate with the MG center. Once the coalescence process takes place, the energy dispersion associated with the TC and MG is enhanced, which rapidly strengthens southwesterly flows on the eastern flanks. The resulting steering flow leads the TC to take a sharp northward track.

  7. Probing the Cosmic Gamma-Ray Burst Rate with Trigger Simulations of the Swift Burst Alert Telescope

    Lien, Amy; Sakamoto, Takanori; Gehrels, Neil; Palmer, David M.; Barthelmy, Scott D.; Graziani, Carlo; Cannizzo, John K.

    2013-01-01

    The gamma-ray burst (GRB) rate is essential for revealing the connection between GRBs, supernovae and stellar evolution. Additionally, the GRB rate at high redshift provides a strong probe of star formation history in the early universe. While hundreds of GRBs are observed by Swift, it remains difficult to determine the intrinsic GRB rate due to the complex trigger algorithm of Swift. Current studies of the GRB rate usually approximate the Swift trigger algorithm by a single detection threshold. However, unlike the previously own GRB instruments, Swift has over 500 trigger criteria based on photon count rate and additional image threshold for localization. To investigate possible systematic biases and explore the intrinsic GRB properties, we develop a program that is capable of simulating all the rate trigger criteria and mimicking the image threshold. Our simulations show that adopting the complex trigger algorithm of Swift increases the detection rate of dim bursts. As a result, our simulations suggest bursts need to be dimmer than previously expected to avoid over-producing the number of detections and to match with Swift observations. Moreover, our results indicate that these dim bursts are more likely to be high redshift events than low-luminosity GRBs. This would imply an even higher cosmic GRB rate at large redshifts than previous expectations based on star-formation rate measurements, unless other factors, such as the luminosity evolution, are taken into account. The GRB rate from our best result gives a total number of 4568 +825 -1429 GRBs per year that are beamed toward us in the whole universe.

  8. Modeling and simulation of deformation and fracture behavior of components made of fully lamellar {gamma}TiAl alloy

    Kabir, Mohammad Rizviul [GKSS-Forschungszentrum Geesthacht GmbH (Germany). Inst. fuer Materialforschung

    2008-07-01

    The present work deals with the modeling and simulation of deformation and fracture behavior of fully lamellar {gamma}TiAl alloy; focusing on understanding the variability of local material properties and their influences on translamellar fracture. Afracture model has been presented that takes the inhomogeneity of the local deformation behavior of the lamellar colonies as well as the variability in fracture strength and toughness into consideration. To obtain the necessary model parameters, a hybrid methodology of experiments and simulations has been adopted. The experiments were performed at room temperature that demonstrates quasi-brittle response of the TiAl polycrystal. Aremarkable variation in stress-strain curves has been found in the tensile tests. Additional fracture tests showed significant variations in crack initiation and propagation during translamellar fracture. Analyzing the fracture surfaces, the micromechanical causes of these macroscopic scatter have been explained. The investigation shows that the global scatter in deformation and fracture response is highly influenced by the colony orientation and tilting angle with respect to the loading axis. The deformation and fracture behavior have been simulated by a finite element model including the material decohesion process described by a cohesive model. In order to capture the scatter of the macroscopic behavior, a stochastic approach is chosen. The local variability of stressstrain in the polycrystal and the variability of fracture parameters of the colonies are implemented in the stochastic approach of the cohesive model. It has been shown that the proposed approach is able to predict the stochastic nature of crack initiation and propagation as observed from the experiments. The global specimen failure with stable or unstable crack propagation can be explained in terms of the local variation of material properties. (orig.)

  9. Failure Bounding And Sensitivity Analysis Applied To Monte Carlo Entry, Descent, And Landing Simulations

    Gaebler, John A.; Tolson, Robert H.

    2010-01-01

    In the study of entry, descent, and landing, Monte Carlo sampling methods are often employed to study the uncertainty in the designed trajectory. The large number of uncertain inputs and outputs, coupled with complicated non-linear models, can make interpretation of the results difficult. Three methods that provide statistical insights are applied to an entry, descent, and landing simulation. The advantages and disadvantages of each method are discussed in terms of the insights gained versus the computational cost. The first method investigated was failure domain bounding which aims to reduce the computational cost of assessing the failure probability. Next a variance-based sensitivity analysis was studied for the ability to identify which input variable uncertainty has the greatest impact on the uncertainty of an output. Finally, probabilistic sensitivity analysis is used to calculate certain sensitivities at a reduced computational cost. These methods produce valuable information that identifies critical mission parameters and needs for new technology, but generally at a significant computational cost.

  10. Sensitivity of WRF-simulated planetary boundary layer height to land cover and soil changes

    Ferenc Ács

    2014-09-01

    Full Text Available Planetary boundary layer (PBL height sensitivity to both so-called single and accumulated land cover and soil changes is investigated in shallow convection under cloud-free conditions to compare the effects. Single land cover type and soil changes are carried out to be able to unequivocally separate the cause and effect relationships. The Yonsei University scheme in the framework of the Weather Research Forecasting (WRF mesoscale modeling system is used as a research tool. The area investigated lies in the Carpathian Basin, where anticyclonic weather type influence dominated on the five summer days chosen for simulations. Observation-based methods applied for validating diurnal PBL height courses manifest great deviations reaching 500–1300 m. The obtained deviations are somewhat smaller around midday and greater at night. They can originate either from the differences in the measuring principles or from the differences in the atmospheric profiles used. Concerning sensitivity analyses, we showed that PBL height differences caused by soil change are comparable with the PBL height differences caused by land cover change. The differences are much greater in the single than in the accumulated tests. Space averaged diurnal course difference around midday reaching a few tens of meters can be presumably treated as strongly significant. PBL height differences obtained in the sensitivity analyses are, at least in our case, smaller than those obtained by applying different observation based methods. The results may be utilized in PBL height diurnal course analyses.

  11. Can Simulation Credibility Be Improved Using Sensitivity Analysis to Understand Input Data Effects on Model Outcome?

    Myers, Jerry G.; Young, M.; Goodenow, Debra A.; Keenan, A.; Walton, M.; Boley, L.

    2015-01-01

    Model and simulation (MS) credibility is defined as, the quality to elicit belief or trust in MS results. NASA-STD-7009 [1] delineates eight components (Verification, Validation, Input Pedigree, Results Uncertainty, Results Robustness, Use History, MS Management, People Qualifications) that address quantifying model credibility, and provides guidance to the model developers, analysts, and end users for assessing the MS credibility. Of the eight characteristics, input pedigree, or the quality of the data used to develop model input parameters, governing functions, or initial conditions, can vary significantly. These data quality differences have varying consequences across the range of MS application. NASA-STD-7009 requires that the lowest input data quality be used to represent the entire set of input data when scoring the input pedigree credibility of the model. This requirement provides a conservative assessment of model inputs, and maximizes the communication of the potential level of risk of using model outputs. Unfortunately, in practice, this may result in overly pessimistic communication of the MS output, undermining the credibility of simulation predictions to decision makers. This presentation proposes an alternative assessment mechanism, utilizing results parameter robustness, also known as model input sensitivity, to improve the credibility scoring process for specific simulations.

  12. Simulation and measurement of short infrared pulses on silicon position sensitive device

    Krapohl, D; Esebamen, O X; Nilsson, H E; Thungstroem, G

    2011-01-01

    Lateral position sensitive devices (PSD) are important for triangulation, alignment and surface measurements as well as for angle measurements. Large PSDs show a delay on rising and falling edges when irradiated with near infra-red light. This delay is also dependent on the spot position relative to the electrodes. It is however desirable in most applications to have a fast response. We investigated the responsiveness of a Sitek PSD in a mixed mode simulation of a two dimensional full sized detector. For simulation and measurement purposes focused light pulses with a wavelength of 850 nm, duration of 1μs and spot size of 280μm were used. The cause for the slopes of rise and fall time is due to time constants of the device capacitance as well as the photo-generation mechanism itself. To support the simulated results, we conducted measurements of rise and fall times on a physical device. Additionally, we quantified the homogeneity of the device by repositioning a spot of light from a pulsed ir-laser diode on the surface area.

  13. The Microwave Properties of Simulated Melting Precipitation Particles: Sensitivity to Initial Melting

    Johnson, B. T.; Olson, W. S.; Skofronick-Jackson, G.

    2016-01-01

    A simplified approach is presented for assessing the microwave response to the initial melting of realistically shaped ice particles. This paper is divided into two parts: (1) a description of the Single Particle Melting Model (SPMM), a heuristic melting simulation for ice-phase precipitation particles of any shape or size (SPMM is applied to two simulated aggregate snow particles, simulating melting up to 0.15 melt fraction by mass), and (2) the computation of the single-particle microwave scattering and extinction properties of these hydrometeors, using the discrete dipole approximation (via DDSCAT), at the following selected frequencies: 13.4, 35.6, and 94.0GHz for radar applications and 89, 165.0, and 183.31GHz for radiometer applications. These selected frequencies are consistent with current microwave remote-sensing platforms, such as CloudSat and the Global Precipitation Measurement (GPM) mission. Comparisons with calculations using variable-density spheres indicate significant deviations in scattering and extinction properties throughout the initial range of melting (liquid volume fractions less than 0.15). Integration of the single-particle properties over an exponential particle size distribution provides additional insight into idealized radar reflectivity and passive microwave brightness temperature sensitivity to variations in size/mass, shape, melt fraction, and particle orientation.

  14. Sensitivity of simulated transcranial ultrasound fields to acoustic medium property maps

    Robertson, James; Martin, Eleanor; Cox, Ben; Treeby, Bradley E.

    2017-04-01

    High intensity transcranial focused ultrasound is an FDA approved treatment for essential tremor, while low-intensity applications such as neurostimulation and opening the blood brain barrier are under active research. Simulations of transcranial ultrasound propagation are used both for focusing through the skull, and predicting intracranial fields. Maps of the skull acoustic properties are necessary for accurate simulations, and can be derived from medical images using a variety of methods. The skull maps range from segmented, homogeneous models, to fully heterogeneous models derived from medical image intensity. In the present work, the impact of uncertainties in the skull properties is examined using a model of transcranial propagation from a single element focused transducer. The impact of changes in bone layer geometry and the sound speed, density, and acoustic absorption values is quantified through a numerical sensitivity analysis. Sound speed is shown to be the most influential acoustic property, and must be defined with less than 4% error to obtain acceptable accuracy in simulated focus pressure, position, and volume. Changes in the skull thickness of as little as 0.1 mm can cause an error in peak intracranial pressure of greater than 5%, while smoothing with a 1 \\text{m}{{\\text{m}}3} kernel to imitate the effect of obtaining skull maps from low resolution images causes an increase of over 50% in peak pressure. The numerical results are confirmed experimentally through comparison with sonications made through 3D printed and resin cast skull bone phantoms.

  15. Lattice Boltzmann simulation for temperature-sensitive magnetic fluids in a porous square cavity

    Jin Licong; Zhang Xinrong; Niu Xiaodong

    2012-01-01

    A lattice Boltzmann method is developed to simulate temperature-sensitive magnetic fluids in a porous cavity. In the simulation, the magnetic force, efficient gravity, viscous loss term and geometric loss term in porous medium are imported to the momentum equation. To test the reliability of the method, a validation with water in porous cavity is carried out. Good agreements with the previous results verify that the present lattice Boltzmann method is promising for simulation of magnetic fluids in porous medium. In this study, we investigate the change of magnetization with external magnetic field, and we present numerical results for the streamlines, isotherms, and magnetization at vertical or horizontal mid-profiles for different values of Ram. In addition, Nusselt numbers changing with magnetic Rayleigh numbers are also investigated. - Highlights: → Developed a lattice Boltzmann method for magnetic nano-fluids in porous cavity. → Clarified flow and heat transfer for different values of (magnetic) Rayleigh numbers. → Heat transfer enhancement for magnetic fluid in porous cavity.

  16. Sensitivity of the LHC isolated-gamma+jet data to the parton distribution functions of the proton

    Carminati, L.; D'Enterria, D.; Koletsou, I.; Marchiori, G.; Rojo, J.; Stockton, M.; Tartarelli, F.

    2013-01-01

    We study the impact of differential isolated-photon+jet cross sections measured in proton-proton collisions at a center-of-mass energy of sqrt{s} = 7 TeV on the parton distribution functions (PDF) of the proton. Next-to-leading order perturbative QCD (pQCD) calculations complemented with the NNPDF2.1 parton densities, and a Bayesian PDF reweighting method are employed. We find that although the current data provide only mild constraints to the parton densities, future gamma-jet measurements with reduced experimental uncertainties can improve our knowledge of the gluon density over a wide range of parton fractional momenta x as well as of the quarks at low-x.

  17. Sensitivity Analysis for CO2 Retrieval using GOSAT-2 FTS-2 Simulator

    Kamei, Akihide; Yoshida, Yukio; Dupuy, Eric; Yokota, Yasuhiro; Hiraki, Kaduo; Matsunaga, Tsuneo

    2015-04-01

    various observing modes including calibration observation, the use of surface and atmospheric ancillary data for radiative transfer calculation, and the speed-up and parallelization of the radiative transfer code. We will summarize the current status and the future plans in the development of the GOSAT-2 FTS-2 simulator. We will also demonstrate the reproduction of GOSAT FTS L1B data and present the sensitivity analysis relating to the engineering parameters, the aerosols and clouds, and so on, on the Level 1 processing for CO2 retrieval using latest version of the GOSAT-2 FTS-2 simulator.

  18. Development of high sensitivity gamma and beta sensors for in situ diffusion tests in the mudstone in France

    Lin, Zhenhua

    2017-01-01

    The precise monitoring of radiotracers, for example used for medical imaging, for the storage of ultimate waste, or for certain industrial applications can be a very complex subject. The development of low-noise sensors with long-term stability and high geometric flexibility were engaged by the AXINT company. (Hautefeuille, et al., 2006). My PhD thesis was focused on experiments in the diffusion of radiotracers, typically to monitor the possible leakage of radioactive products from the geological repositories. We focuses on the study of the "2"2Na and "3"6Cl ion diffusion, which is one of the highest cation and anions diffusion rate in geological medium, as well as actinides, which represent the majority of the radioactive elements of Stored nuclear waste. This thesis is in continuity with the research carried out by ANDRA (National Agency for Radioactive Waste), under contract with the laboratory ILM (Institute Light Matter), of which AXINT is the main subcontractor. The present project describes the research work that foreseen the radiation impact on the environment for the coming years during the deep disposal of nuclear waste. Our work focus on the investigation and quantification of the radionuclide diffusion through the geological clay barriers. A new in situ experiment was considered by Andra for the study of the radionuclide migration. Compared to previous experiments, this new in situ diffusion test required longer distance (hundreds of mm), longer time-scale (over 10 years), and real time in situ monitoring of radionuclides migration. To fulfill these conditions, the work was organized as following: 1: Conception and dimensional design of the Diffusion of Radio Nuclide (DRN) experiments in solving emission of beta and gamma radiations 2: Development of corresponding beta and gamma monitoring systems by means of sensors located in peripheral boreholes. (author) [fr

  19. Sensitivity analysis of an individual-based model for simulation of influenza epidemics.

    Elaine O Nsoesie

    Full Text Available Individual-based epidemiology models are increasingly used in the study of influenza epidemics. Several studies on influenza dynamics and evaluation of intervention measures have used the same incubation and infectious period distribution parameters based on the natural history of influenza. A sensitivity analysis evaluating the influence of slight changes to these parameters (in addition to the transmissibility would be useful for future studies and real-time modeling during an influenza pandemic.In this study, we examined individual and joint effects of parameters and ranked parameters based on their influence on the dynamics of simulated epidemics. We also compared the sensitivity of the model across synthetic social networks for Montgomery County in Virginia and New York City (and surrounding metropolitan regions with demographic and rural-urban differences. In addition, we studied the effects of changing the mean infectious period on age-specific epidemics. The research was performed from a public health standpoint using three relevant measures: time to peak, peak infected proportion and total attack rate. We also used statistical methods in the design and analysis of the experiments. The results showed that: (i minute changes in the transmissibility and mean infectious period significantly influenced the attack rate; (ii the mean of the incubation period distribution appeared to be sufficient for determining its effects on the dynamics of epidemics; (iii the infectious period distribution had the strongest influence on the structure of the epidemic curves; (iv the sensitivity of the individual-based model was consistent across social networks investigated in this study and (v age-specific epidemics were sensitive to changes in the mean infectious period irrespective of the susceptibility of the other age groups. These findings suggest that small changes in some of the disease model parameters can significantly influence the uncertainty

  20. Simulation of the isotopic ratio determination of plutonium by Ge(Li) gamma-ray spectrometry

    Baba, Hiroshi; Yagi, Hideyuki

    1979-09-01

    A simulation program ''SIMPUG'' was developed for assessing feasibility of the isotopic ratio determination of plutonium by Ge(Li) γ-ray spectrometry. The program consists of (1) construction of the spectrum profiles for eight peak groupings of interest with a given set of isotopic compositions and by the use of the known nuclear data for emitting γ rays and (2) determination of the intensity of each participating nuclide following a presently developed algorithm of spectrum unfolding. Effects of various factors on the reliability of the results were examined with the simulation program. Accuracy of the results was found to be little affected by the change of the detector resolution if the spectrum was taken with sufficient expansion. Counting statistics was concluded to be the most essential factor for the precision of the results, while the aging effect was not found significant. Contamination of fission products beyond a certain level brought about fatal errors in the determined values, particularly in the case of minor components. (author)

  1. Feasibility study for an airborne high-sensitivity gamma-ray survey of Alaska. Phase II (final) report: 1976--1979 program

    1975-01-01

    This study constitutes a determination of the extent to which it is feasible to use airborne, high-sensitivity gamma spectrometer systems for uranium reconnaissance in the State of Alaska, and specification of a preliminary plan for surveying the entire state of the 1975--1979 time frame. Phase I included the design of a program to survey the highest priority areas in 1975 using available aircraft and spectrometer equipment. This has now resulted in a contract for 10,305 flight line miles to cover about 11 of the 1:250,000 scale quadrangles using a DC-3 aircraft with an average 6.25 x 25 mile grid of flight line. Phase II includes the design of alternative programs to cover the remaining 128 quadrangles using either a DC-3 and a Bell 205A helicopter or a Helio Stallion STOL aircraft and a Bell 205A helicopter during 1976-1979. The 1976-1979 time frame allows some time for possible new system developments in both airborne gamma-ray spectrometers and in ancillary equipment, and these are outlined. (auth)

  2. Gamma oscillations and spontaneous network activity in the hippocampus are highly sensitive to decreases in pO2 and concomitant changes in mitochondrial redox state.

    Huchzermeyer, Christine; Albus, Klaus; Gabriel, Hans-Jürgen; Otáhal, Jakub; Taubenberger, Nando; Heinemann, Uwe; Kovács, Richard; Kann, Oliver

    2008-01-30

    Gamma oscillations have been implicated in higher cognitive processes and might critically depend on proper mitochondrial function. Using electrophysiology, oxygen sensor microelectrode, and imaging techniques, we investigated the interactions of neuronal activity, interstitial pO2, and mitochondrial redox state [NAD(P)H and FAD (flavin adenine dinucleotide) fluorescence] in the CA3 subfield of organotypic hippocampal slice cultures. We find that gamma oscillations and spontaneous network activity decrease significantly at pO2 levels that do not affect neuronal population responses as elicited by moderate electrical stimuli. Moreover, pO2 and mitochondrial redox states are tightly coupled, and electrical stimuli reveal transient alterations of redox responses when pO2 decreases within the normoxic range. Finally, evoked redox responses are distinct in somatic and synaptic neuronal compartments and show different sensitivity to changes in pO2. We conclude that the threshold of interstitial pO2 for robust CA3 network activities and required mitochondrial function is clearly above the "critical" value, which causes spreading depression as a result of generalized energy failure. Our study highlights the importance of a functional understanding of mitochondria and their implications on activities of individual neurons and neuronal networks.

  3. From neural oscillations to reasoning ability: Simulating the effect of the theta-to-gamma cycle length ratio on individual scores in a figural analogy test.

    Chuderski, Adam; Andrelczyk, Krzysztof

    2015-02-01

    Several existing computational models of working memory (WM) have predicted a positive relationship (later confirmed empirically) between WM capacity and the individual ratio of theta to gamma oscillatory band lengths. These models assume that each gamma cycle represents one WM object (e.g., a binding of its features), whereas the theta cycle integrates such objects into the maintained list. As WM capacity strongly predicts reasoning, it might be expected that this ratio also predicts performance in reasoning tasks. However, no computational model has yet explained how the differences in the theta-to-gamma ratio found among adult individuals might contribute to their scores on a reasoning test. Here, we propose a novel model of how WM capacity constraints figural analogical reasoning, aimed at explaining inter-individual differences in reasoning scores in terms of the characteristics of oscillatory patterns in the brain. In the model, the gamma cycle encodes the bindings between objects/features and the roles they play in the relations processed. Asynchrony between consecutive gamma cycles results from lateral inhibition between oscillating bindings. Computer simulations showed that achieving the highest WM capacity required reaching the optimal level of inhibition. When too strong, this inhibition eliminated some bindings from WM, whereas, when inhibition was too weak, the bindings became unstable and fell apart or became improperly grouped. The model aptly replicated several empirical effects and the distribution of individual scores, as well as the patterns of correlations found in the 100-people sample attempting the same reasoning task. Most importantly, the model's reasoning performance strongly depended on its theta-to-gamma ratio in same way as the performance of human participants depended on their WM capacity. The data suggest that proper regulation of oscillations in the theta and gamma bands may be crucial for both high WM capacity and effective complex

  4. ALMERA Proficiency Test: Determination of Gamma Emitting Radionuclides in Simulated Air Filters

    2010-01-01

    The activity concentration of radionuclides in air is a critical factor in assessing the air quality and the potential impact of possible pollutants. Air is in fact one of the main pathways for human exposure to radioactivity. Radioactivity may be present in the atmosphere due to natural processes; intentional (low level) anthropogenic release; or as a consequence of nuclear or radiological incident. The resulting environmental impact should be considered carefully to ensure safety and compliance with environmental regulations. A reliable determination of radionuclides in air is necessary for regular monitoring of air quality to comply with radiation protection and environmental regulations. This proficiency test (PT) is one of the series of the ALMERA network proficiency tests organised on regular basis by the Terrestrial Environment Laboratory in Seibersdorf, designed to assess the technical capacity of ALMERA Members in analysing radionuclides to identify any analytical problems and to support ALMERA laboratories to maintain their preparedness to provide rapid and reliable analytical results. The range of simulated air filters used in this PT for analysis has been mainly at environmental level. The PT set consisted of four filters. The participating laboratories were requested to analyze Mn-54, Co-57, Fe-59, Co-60, Zn-65, Cd-109, Ba-133, Cs-134, Cs-137, Eu-152 and Am-241 in filters 01, 02 and 03. The participants were informed that only some of the listed radionuclides were present in the filters and the levels of the radionuclides were such that they could be measured within a 6-hour measurement period using a conventional HPGe gammaspectrometer of 35% relative efficiency. Filter 04, was containing only Co-60 and Ba-133 with known activities to the participants, had to be used as a control for the efficiency calibration. The tasks of IAEA were to prepare and distribute the simulated air filters to the participating laboratories, to collect and interpret

  5. Sensitivity analysis and uncertainties simulation of the migration of radionuclide in the system of geological disposal-CRP-GEORC model

    Su Rui; Wang Ju; Chen Weiming; Zong Zihua; Zhao Honggang

    2008-01-01

    CRP-GEORC concept model is an artificial system of geological disposal for High-Level radioactive waste. Sensitivity analysis and uncertainties simulation of the migration of radionuclide Se-79 and I-129 in the far field of this system by using GoldSim Code have been conducted. It can be seen from the simulation results that variables used to describe the geological features and characterization of groundwater flow are sensitive variables of whole geological disposal system. The uncertainties of parameters have remarkable influence on the simulation results. (authors)

  6. Use of gamma-rays sensitivity for discrimination of upland cultivars of groups Indican and Japonica; Uso da sensitividade a radiacao gama na discriminacao de variedades de arroz-de-sequeiro dos grupos Indica e Japonica

    Rodrigues, Luis Roberto Franco [UNESP, Botucatu, SP (Brazil). Dept. de Genetica; Ando, Akihiko [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil)

    2003-07-01

    Sixty-five upland rice cultivars (Oryza sativa L.) were evaluated in relation to gamma-ray sensitivity. Seeds were subjected to seven doses of gamma-radiation and sown in wooden boxes in randomised complete block design with three replications. The experiment was conducted in greenhouse during the year of 1992. Physiological effects caused by radiation in the M{sub 1} generation, were evaluated. The results showed that the sensitivity to the radiation at doses 300 and 360 Gy was useful for distinguishing Indican and Japonica groups. (author)

  7. Gamma irradiator

    Simonet, G.

    1986-09-01

    Fiability of devices set around reactors depends on material resistance under irradiation noticeably joints, insulators, which belongs to composition of technical, safety or physical incasurement devices. The irradiated fuel elements, during their desactivation in a pool, are an interesting gamma irradiation device to simulate damages created in a nuclear environment. The existing facility at Osiris allows to generate an homogeneous rate dose in an important volume. The control of the element distances to irradiation box allows to control this dose rate [fr

  8. Data-driven Simulations of Magnetic Connectivity in Behind-the-Limb Gamma-ray Flares and Associated Coronal Mass Ejections

    Jin, M.; Petrosian, V.; Liu, W.; Nitta, N.; Omodei, N.; Rubio da Costa, F.; Effenberger, F.; Li, G.; Pesce-Rollins, M.

    2017-12-01

    Recent Fermi detection of high-energy gamma-ray emission from the behind-the-limb (BTL) solar flares pose a puzzle on the particle acceleration and transport mechanisms in such events. Due to the large separation between the flare site and the location of gamma-ray emission, it is believed that the associated coronal mass ejections (CMEs) play an important role in accelerating and subsequently transporting particles back to the Sun to produce obseved gamma-rays. We explore this scenario by simulating the CME associated with a well-observed flare on 2014 September 1 about 40 degrees behind the east solar limb and by comparing the simulation and observational results. We utilize a data-driven global magnetohydrodynamics model (AWSoM: Alfven-wave Solar Model) to track the dynamical evolution of the global magnetic field during the event and investigate the magnetic connectivity between the CME/CME-driven shock and the Fermi emission region. Moreover, we derive the time-varying shock parameters (e.g., compression ratio, Alfven Mach number, and ThetaBN) over the area that is magnetically connected to the visible solar disk where Fermi gamma-ray emission originates. Our simulation shows that the visible solar disk develops connections both to the flare site and to the CME-driven shock during the eruption, which indicate that the CME's interaction with the global solar corona is critical for understanding such Fermi BTL events and gamma-ray flares in general. We discuss the causes and implications of Fermi BTL events, in the framework of a potential shift of paradigm on particle acceleration in solar flares/CMEs.

  9. Simulating mixed-phase Arctic stratus clouds: sensitivity to ice initiation mechanisms

    G. McFarquhar

    2009-07-01

    Full Text Available The importance of Arctic mixed-phase clouds on radiation and the Arctic climate is well known. However, the development of mixed-phase cloud parameterization for use in large scale models is limited by lack of both related observations and numerical studies using multidimensional models with advanced microphysics that provide the basis for understanding the relative importance of different microphysical processes that take place in mixed-phase clouds. To improve the representation of mixed-phase cloud processes in the GISS GCM we use the GISS single-column model coupled to a bin resolved microphysics (BRM scheme that was specially designed to simulate mixed-phase clouds and aerosol-cloud interactions. Using this model with the microphysical measurements obtained from the DOE ARM Mixed-Phase Arctic Cloud Experiment (MPACE campaign in October 2004 at the North Slope of Alaska, we investigate the effect of ice initiation processes and Bergeron-Findeisen process (BFP on glaciation time and longevity of single-layer stratiform mixed-phase clouds. We focus on observations taken during 9–10 October, which indicated the presence of a single-layer mixed-phase clouds. We performed several sets of 12-h simulations to examine model sensitivity to different ice initiation mechanisms and evaluate model output (hydrometeors' concentrations, contents, effective radii, precipitation fluxes, and radar reflectivity against measurements from the MPACE Intensive Observing Period. Overall, the model qualitatively simulates ice crystal concentration and hydrometeors content, but it fails to predict quantitatively the effective radii of ice particles and their vertical profiles. In particular, the ice effective radii are overestimated by at least 50%. However, using the same definition as used for observations, the effective radii simulated and that observed were more comparable. We find that for the single-layer stratiform mixed-phase clouds simulated, process

  10. Simulating mixed-phase Arctic stratus clouds: sensitivity to ice initiation mechanisms

    Sednev, I.; Menon, S.; McFarquhar, G.

    2009-07-01

    The importance of Arctic mixed-phase clouds on radiation and the Arctic climate is well known. However, the development of mixed-phase cloud parameterization for use in large scale models is limited by lack of both related observations and numerical studies using multidimensional models with advanced microphysics that provide the basis for understanding the relative importance of different microphysical processes that take place in mixed-phase clouds. To improve the representation of mixed-phase cloud processes in the GISS GCM we use the GISS single-column model coupled to a bin resolved microphysics (BRM) scheme that was specially designed to simulate mixed-phase clouds and aerosol-cloud interactions. Using this model with the microphysical measurements obtained from the DOE ARM Mixed-Phase Arctic Cloud Experiment (MPACE) campaign in October 2004 at the North Slope of Alaska, we investigate the effect of ice initiation processes and Bergeron-Findeisen process (BFP) on glaciation time and longevity of single-layer stratiform mixed-phase clouds. We focus on observations taken during 9-10 October, which indicated the presence of a single-layer mixed-phase clouds. We performed several sets of 12-h simulations to examine model sensitivity to different ice initiation mechanisms and evaluate model output (hydrometeors' concentrations, contents, effective radii, precipitation fluxes, and radar reflectivity) against measurements from the MPACE Intensive Observing Period. Overall, the model qualitatively simulates ice crystal concentration and hydrometeors content, but it fails to predict quantitatively the effective radii of ice particles and their vertical profiles. In particular, the ice effective radii are overestimated by at least 50%. However, using the same definition as used for observations, the effective radii simulated and that observed were more comparable. We find that for the single-layer stratiform mixed-phase clouds simulated, process of ice phase initiation

  11. Algorithm simulating the atom displacement processes induced by the gamma rays on the base of Monte Carlo method

    Cruz, C. M.; Pinera, I; Abreu, Y.; Leyva, A.

    2007-01-01

    Present work concerns with the implementation of a Monte Carlo based calculation algorithm describing particularly the occurrence of Atom Displacements induced by the Gamma Radiation interactions at a given target material. The Atom Displacement processes were considered only on the basis of single elastic scattering interactions among fast secondary electrons with matrix atoms, which are ejected from their crystalline sites at recoil energies higher than a given threshold energy. The secondary electron transport was described assuming typical approaches on this matter, where consecutive small angle scattering and very low energy transfer events behave as a continuously cuasi-classical electron state changes along a given path length delimited by two discrete high scattering angle and electron energy losses events happening on a random way. A limiting scattering angle was introduced and calculated according Moliere-Bethe-Goudsmit-Saunderson Electron Multiple Scattering, which allows splitting away secondary electrons single scattering processes from multiple one, according which a modified McKinley-Feshbach electron elastic scattering cross section arises. This distribution was statistically sampled and simulated in the framework of the Monte Carlo Method to perform discrete single electron scattering processes, particularly those leading to Atom Displacement events. The possibility of adding this algorithm to present existing open Monte Carlo code systems is analyze, in order to improve their capabilities. (Author)

  12. Plasma characteristics of the end-cell of the GAMMA 10 tandem mirror for the divertor simulation experiment

    Nakashima, Y.; Sakamoto, M.; Yoshikawa, M.; Takeda, H.; Ichimura, K.; Hosoi, K.; Hirata, M.; Ichimura, M.; Ikezoe, R.; Imai, T.; Kariya, T.; Katanuma, I.; Kohagura, J.; Minami, R.; Numakura, T.; Oki, K.; Ueda, H.; Asakura, Nobuyuki; Furuta, T.; Hatayama, A.; Toma, M.; Hirooka, Y.; Masuzaki, S.; Sagara, A.; Shoji, M.; Kado, S.; Matsuura, H.; Nagata, S.; Nishino, N.; Ohno, N.; Tonegawa, A.; Ueda, Y.

    2012-11-01

    In this paper, detailed characteristics and controllability of plasmas emitted from the end-cell of the GAMMA 10 tandem mirror are described from the viewpoint of divertor simulation studies. The energy analysis of ion flux by using end-loss ion energy analyzer (ELIEA) proved that the obtained high ion temperature (100 - 400 eV) was comparable to SOL plasma parameters in toroidal devices and was controlled by changing the ICRF power. Parallel ion temperature T i∥ determined from the probe and calorimeter shows a linear relationship with the ICRF power in the central-cell and agrees with the results of ELIEA. Additional ICRF heating revealed a significant enhancement of particle flux, which indicated an effectiveness of additional plasma heating in adjacent cells toward the improvement of the performance. Superimposing the ECH pulse of 380 kW, 5 ms attained the maximum heat-flux more than 10 MW/m 2 on axis. This value comes up to the heat-load of the divertor plate of ITER, which gives a clear prospect of generating the required heat density for divertor studies by building up heating systems to the end-mirror cell. Initial results of plasma irradiation experiment and construction of new divertor module are also described. (author)

  13. The influence of penetrating gamma radiation on the reaction of simulated nuclear waste glass in tuff groundwater

    Ebert, W.L.; Bates, J.K.; Abrajano, T.A. Jr.; Gerding, T.J.

    1989-01-01

    Static leaching experiments have been performed to determine the influence of penetrating gamma radiation on the reaction of simulated nuclear waste glass in tuff groundwater at 90/degree/C. Both the leachates and the reacted glass monoliths were analyzed to characterize the reaction. Radiation was seen to acidify the leachates, but the high bicarbonate content of the groundwater prevented the pHs from dropping below 6.4. The glass reaction tended to raise the pH. Glass based on SRL 165 black frit and PNL 76-68 glass compositions were leached. The SRL 165 type glasses were quite durable and unaffected by radiation [NL(B) /approximately/4 g/m 2 after 278 days at all exposure rates]. The PNL 76-68 glasses were much less durable, with the durability decreasing as the exposure rate was increased [NL(B) was about 20 g/m 2 after 278 days at 1 /times/ 10 3 R/h for both ATM-1c and ATM-8 glasses]. 8 refs., 5 figs

  14. Changes in antibiotic sensitivity and cell surface hydrophobicity in Escherichia coli injured by heating, freezing, drying or gamma radiation

    Mackey, B.M.

    1983-01-01

    Escherichia coli cells exposed to mild heating, freezing and thawing, drying or γ-radiation were sensitised to hydrophobic antibiotics and sodium deoxycholate but not to small hydrophilic antibiotics. These stress treatments also caused increases in cell surface hydrophobicity broadly reflecting the degree of sensitivity to hydrophobic antibiotics. (Auth.)

  15. Simulation and optimisation of a position sensitive scintillation detector with wavelength shifting fibers for thermal neutrons

    Herzkamp, Matthias; Engels, Ralf; Kemmerling, Guenter [ZEA-2, Forschungszentrum Juelich (Germany); Brueckel, Thomas [JCNS, Forschungszentrum Juelich (Germany); Stahl, Achim [III. Physikalisches Institut B, RWTH Aachen (Germany); Waasen, Stefan van [ZEA-2, Forschungszentrum Juelich (Germany); Faculty of Engineering, University of Duisburg-Essen (Germany)

    2015-07-01

    In neutron scattering experiments it is important to have position sensitive large scale detectors for thermal neutrons. A detector based on a neutron scintillator with wave length shifting fibers is a new kind of such a detector. We present the simulation of the detector based on the microscopic structure of the scintillation material of the mentioned detector. It consists of a converter and a scintillation powder bound in a matrix. The converter in our case is lithium fluoride with enriched lithium 6, to convert thermal neutrons into high energetic alpha and triton particles. The scintillation material is silver doped zinc sulfide. We show that pulse height spectra obtained by these scintillators can be be explained by the simple model of randomly distributed spheres of zinc sulfide and lithium fluoride. With this model, it is possible to optimise the mass ratio of zinc sulfide to lithium fluoride with respect to detection efficiency and/or energy deposition in zinc sulfide.

  16. An analysis of nuclear fuel burnup in the AGR-1 TRISO fuel experiment using gamma spectrometry, mass spectrometry, and computational simulation techniques

    Harp, Jason M.; Demkowicz, Paul A.; Winston, Philip L.; Sterbentz, James W.

    2014-01-01

    Highlights: • The burnup of irradiated AGR-1 TRISO fuel was analyzed using gamma spectrometry. • The burnup of irradiated AGR-1 TRISO fuel was also analyzed using mass spectrometry. • Agreement between experimental results and neutron physics simulations was excellent. - Abstract: AGR-1 was the first in a series of experiments designed to test US TRISO fuel under high temperature gas-cooled reactor irradiation conditions. This experiment was irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) and is currently undergoing post-irradiation examination (PIE) at INL and Oak Ridge National Laboratory. One component of the AGR-1 PIE is the experimental evaluation of the burnup of the fuel by two separate techniques. Gamma spectrometry was used to non-destructively evaluate the burnup of all 72 of the TRISO fuel compacts that comprised the AGR-1 experiment. Two methods for evaluating burnup by gamma spectrometry were developed, one based on the Cs-137 activity and the other based on the ratio of Cs-134 and Cs-137 activities. Burnup values determined from both methods compared well with the values predicted from simulations. The highest measured burnup was 20.1% FIMA (fissions per initial heavy metal atom) for the direct method and 20.0% FIMA for the ratio method (compared to 19.56% FIMA from simulations). An advantage of the ratio method is that the burnup of the cylindrical fuel compacts can be determined in small (2.5 mm) axial increments and an axial burnup profile can be produced. Destructive chemical analysis by inductively coupled mass spectrometry (ICP-MS) was then performed on selected compacts that were representative of the expected range of fuel burnups in the experiment to compare with the burnup values determined by gamma spectrometry. The compacts analyzed by mass spectrometry had a burnup range of 19.3% FIMA to 10.7% FIMA. The mass spectrometry evaluation of burnup for the four compacts agreed well with the gamma

  17. Enhanced oil recovery methods studied by gamma tracer scanning at simulated reservoir conditions

    Eriksen, D.O.; Haugen, O.B.; Bjornstad, T.

    2009-01-01

    During recovery (production) of hydrocarbons pressure is maintained by injecting prepared sea water and recycled gas (lean gas) into dedicated injection wells. In one well at the Snorre field in the North Sea the injected gas was recycled too fast to enable support of pressure and squeezing of oil. To plug this high-permeable area the operator wanted to inject foam as a test of its possibilities to decrease gas permeability. As part of the project laboratory tests were included. In these tests we could for the first time map the foam inside the sandstone sample at simulated reservoir conditions. The tracers used were 22 Na + for the γ-scanning of the aqueous brine, tritiated water for permeability measurements, and 35 S-labeled organic sulfonic acid of the same compound as the surfactant. This method resulted in a 'negative' mapping of the foam, i.e. measurements of the absence or exclusion of the aqueous phase by the foam. This method was new and showed that radiotracer-based γ-scanning could give much more accurate measurements of the position of the foam than the standard method using measurements of pressure drops over parts of the core. (author)

  18. Gamma radiation sensitivity of the eggs, larvae and pupae of Indian meal moth Plodia interpunctella (Hübner) (Lepidoptera: Pyralidae).

    Ayvaz, Abdurrahman; Albayrak, Sevil; Karaborklu, Salih

    2008-05-01

    This study focused on determining the minimal effective gamma radiation dose that prevents commodity damage caused by the Indian meal moth Plodia interpunctella (Hübner). The study was also designed to assess the effect of releasing either partially sterilized males alone or both partially sterilized males and females on the reproductive potential of P. interpunctella populations. The dose of radiation required to prevent larval emergence from irradiated eggs was 350 Gy, and the same dose was also required to prevent adult emergence from mature larvae. A dose of 300 Gy was not able to prevent adult emergence from irradiated pupae. The dose at which 100% sterility was achieved in treated females mated to treated males was 300 Gy for the parental generation of irradiated pupae. Fertility of the parental males from irradiated pupae was 48.17% at 300 Gy in treated males crossed with untreated females, but male progeny of irradiated male parents had a residual fertility of 11.06% at the same dose. F(1) males from irradiated pupae were more sterile than parental males. To prevent larval emergence from irradiated eggs, a dose of 350 Gy is required. The same dose is required to prevent the larvae from reaching the adult stage. Copyright (c) 2008 Society of Chemical Industry.

  19. Sensitivity Analysis on Fire Modeling of Main Control Board Fire Using Fire Dynamics Simulator

    Kang, Dae Il; Lim, Ho Gon

    2015-01-01

    In this study, sensitivity analyses for an MCB fire were performed to identify the effects on the MCR forced abandonment time according to the changes of height and number for fire initiation places. Hanul Unit 3 NPP was selected as a reference plant for this study. In this study, sensitivity analyses for an MCB fire were performed to identify the effects on the MCR forced abandonment time according to the changes of height and number of fire initiation places. A main control board (MCB) fire can cause a forced main control room (MCR) abandonment of the operators as well as the function failures or spurious operations of the control and instrumentation-related components. If the MCR cannot be habitable, a safe shutdown from outside the MCR can be achieved and maintained at an alternate shutdown panel independent from the MCR. When the fire modeling for an electrical cabinet such as an MCB was performed, its many input parameters can affect the fire simulation results. This study results showed that the decrease in the height of fire ignition place and the use of single fire ignition place in fire modeling for the propagating fire shortened MCR abandonment time

  20. Climate-sensitive urban design through Envi-Met simulation: case study in Kemayoran, Jakarta

    Kusumastuty, K. D.; Poerbo, H. W.; Koerniawan, M. D.

    2018-03-01

    Indonesia as a tropical country which the character of its climate are hot and humid, the outdoor activity applications are often disrupted due to discomfort in thermal conditions. Massive construction of skyscrapers in urban areas are caused by the increase of human population leads to reduced green and infiltration areas that impact to environmental imbalances and triggering microclimate changes with rising air temperatures on the surface. The area that significantly experiences the rise of temperature in the Central Business District (CBD), which has need an analysis to create thermal comfort conditions to improve the ease of outdoor activities by an approach. This study aims to design the Kemayoran CBD through Climate Sensitive Urban Design especially in hot and humid tropical climate area and analyze thermal comfort level and optimal air conditioning in the outdoor area. This research used a quantitative method by generating the design using Climate Sensitive Urban Design principle through Envi-met 4.1 simulation program to find out the value of PMV, air temperature, wind speed and relative humidity conditions. The design area considers the configuration of buildings such as the distance between buildings, the average height, the orientation of the building, and the width of the road.

  1. Monte Carlo simulation for slip rate sensitivity analysis in Cimandiri fault area

    Pratama, Cecep, E-mail: great.pratama@gmail.com [Graduate Program of Earth Science, Faculty of Earth Science and Technology, ITB, JalanGanesa no. 10, Bandung 40132 (Indonesia); Meilano, Irwan [Geodesy Research Division, Faculty of Earth Science and Technology, ITB, JalanGanesa no. 10, Bandung 40132 (Indonesia); Nugraha, Andri Dian [Global Geophysical Group, Faculty of Mining and Petroleum Engineering, ITB, JalanGanesa no. 10, Bandung 40132 (Indonesia)

    2015-04-24

    Slip rate is used to estimate earthquake recurrence relationship which is the most influence for hazard level. We examine slip rate contribution of Peak Ground Acceleration (PGA), in probabilistic seismic hazard maps (10% probability of exceedance in 50 years or 500 years return period). Hazard curve of PGA have been investigated for Sukabumi using a PSHA (Probabilistic Seismic Hazard Analysis). We observe that the most influence in the hazard estimate is crustal fault. Monte Carlo approach has been developed to assess the sensitivity. Then, Monte Carlo simulations properties have been assessed. Uncertainty and coefficient of variation from slip rate for Cimandiri Fault area has been calculated. We observe that seismic hazard estimates is sensitive to fault slip rate with seismic hazard uncertainty result about 0.25 g. For specific site, we found seismic hazard estimate for Sukabumi is between 0.4904 – 0.8465 g with uncertainty between 0.0847 – 0.2389 g and COV between 17.7% – 29.8%.

  2. Sensitivity Analysis on Fire Modeling of Main Control Board Fire Using Fire Dynamics Simulator

    Kang, Dae Il; Lim, Ho Gon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    In this study, sensitivity analyses for an MCB fire were performed to identify the effects on the MCR forced abandonment time according to the changes of height and number for fire initiation places. Hanul Unit 3 NPP was selected as a reference plant for this study. In this study, sensitivity analyses for an MCB fire were performed to identify the effects on the MCR forced abandonment time according to the changes of height and number of fire initiation places. A main control board (MCB) fire can cause a forced main control room (MCR) abandonment of the operators as well as the function failures or spurious operations of the control and instrumentation-related components. If the MCR cannot be habitable, a safe shutdown from outside the MCR can be achieved and maintained at an alternate shutdown panel independent from the MCR. When the fire modeling for an electrical cabinet such as an MCB was performed, its many input parameters can affect the fire simulation results. This study results showed that the decrease in the height of fire ignition place and the use of single fire ignition place in fire modeling for the propagating fire shortened MCR abandonment time.

  3. Ozone Sensitivity to Varying Greenhouse Gases and Ozone-Depleting Substances in CCMI-1 Simulations

    Morgenstern, Olaf; Stone, Kane A.; Schofield, Robyn; Akiyoshi, Hideharu; Yamashita, Yousuke; Kinnison, Douglas E.; Garcia, Rolando R.; Sudo, Kengo; Plummer, David A.; Scinocca, John; hide

    2018-01-01

    Ozone fields simulated for the first phase of the Chemistry-Climate Model Initiative (CCMI-1) will be used as forcing data in the 6th Coupled Model Intercomparison Project. Here we assess, using reference and sensitivity simulations produced for CCMI-1, the suitability of CCMI-1 model results for this process, investigating the degree of consistency amongst models regarding their responses to variations in individual forcings. We consider the influences of methane, nitrous oxide, a combination of chlorinated or brominated ozone-depleting substances, and a combination of carbon dioxide and other greenhouse gases. We find varying degrees of consistency in the models' responses in ozone to these individual forcings, including some considerable disagreement. In particular, the response of total-column ozone to these forcings is less consistent across the multi-model ensemble than profile comparisons. We analyse how stratospheric age of air, a commonly used diagnostic of stratospheric transport, responds to the forcings. For this diagnostic we find some salient differences in model behaviour, which may explain some of the findings for ozone. The findings imply that the ozone fields derived from CCMI-1 are subject to considerable uncertainties regarding the impacts of these anthropogenic forcings. We offer some thoughts on how to best approach the problem of generating a consensus ozone database from a multi-model ensemble such as CCMI-1.

  4. Ozone sensitivity to varying greenhouse gases and ozone-depleting substances in CCMI-1 simulations

    O. Morgenstern

    2018-01-01

    Full Text Available Ozone fields simulated for the first phase of the Chemistry-Climate Model Initiative (CCMI-1 will be used as forcing data in the 6th Coupled Model Intercomparison Project. Here we assess, using reference and sensitivity simulations produced for CCMI-1, the suitability of CCMI-1 model results for this process, investigating the degree of consistency amongst models regarding their responses to variations in individual forcings. We consider the influences of methane, nitrous oxide, a combination of chlorinated or brominated ozone-depleting substances, and a combination of carbon dioxide and other greenhouse gases. We find varying degrees of consistency in the models' responses in ozone to these individual forcings, including some considerable disagreement. In particular, the response of total-column ozone to these forcings is less consistent across the multi-model ensemble than profile comparisons. We analyse how stratospheric age of air, a commonly used diagnostic of stratospheric transport, responds to the forcings. For this diagnostic we find some salient differences in model behaviour, which may explain some of the findings for ozone. The findings imply that the ozone fields derived from CCMI-1 are subject to considerable uncertainties regarding the impacts of these anthropogenic forcings. We offer some thoughts on how to best approach the problem of generating a consensus ozone database from a multi-model ensemble such as CCMI-1.

  5. Sensitivity of air pollution simulations with LOTOS-EUROS to the temporal distribution of anthropogenic emissions

    Mues, A.; Kuenen, J.; Hendriks, C.; Manders, A.; Segers, A.; Scholz, Y.; Hueglin, C.; Builtjes, P.; Schaap, M.

    2014-01-01

    In this study the sensitivity of the model performance of the chemistry transport model (CTM) LOTOS-EUROS to the description of the temporal variability of emissions was investigated. Currently the temporal release of anthropogenic emissions is described by European average diurnal, weekly and seasonal time profiles per sector. These default time profiles largely neglect the variation of emission strength with activity patterns, region, species, emission process and meteorology. The three sources dealt with in this study are combustion in energy and transformation industries (SNAP1), nonindustrial combustion (SNAP2) and road transport (SNAP7). First of all, the impact of neglecting the temporal emission profiles for these SNAP categories on simulated concentrations was explored. In a second step, we constructed more detailed emission time profiles for the three categories and quantified their impact on the model performance both separately as well as combined. The performance in comparison to observations for Germany was quantified for the pollutants NO2, SO2 and PM10 and compared to a simulation using the default LOTOS-EUROS emission time profiles. The LOTOS-EUROS simulations were performed for the year 2006 with a temporal resolution of 1 h and a horizontal resolution of approximately 25 × 25km2. In general the largest impact on the model performance was found when neglecting the default time profiles for the three categories. The daily average correlation coefficient for instance decreased by 0.04 (NO2), 0.11 (SO2) and 0.01 (PM10) at German urban background stations compared to the default simulation. A systematic increase in the correlation coefficient is found when using the new time profiles. The size of the increase depends on the source category, component and station. Using national profiles for road transport showed important improvements in the explained variability over the weekdays as well as the diurnal cycle for NO2. The largest impact of the SNAP1

  6. Performance Verification of GOSAT-2 FTS-2 Simulator and Sensitivity Analysis for Greenhouse Gases Retrieval

    Kamei, A.; Yoshida, Y.; Dupuy, E.; Hiraki, K.; Matsunaga, T.

    2015-12-01

    performance verification of the GOSAT-2 FTS-2 simulator and describe the future prospects for Level 2 retrieval. Besides, we will present the various sensitivity analyses relating to the engineering parameters and the atmospheric conditions on Level 1 processing for greenhouse gases retrieval.

  7. Adipocyte-specific blockade of gamma-secretase, but not inhibition of Notch activity, reduces adipose insulin sensitivity

    David P. Sparling

    2016-02-01

    Full Text Available Objective: As the obesity pandemic continues to expand, novel molecular targets to reduce obesity-related insulin resistance and Type 2 Diabetes (T2D continue to be needed. We have recently shown that obesity is associated with reactivated liver Notch signaling, which, in turn, increases hepatic insulin resistance, opening up therapeutic avenues for Notch inhibitors to be repurposed for T2D. Herein, we tested the systemic effects of γ-secretase inhibitors (GSIs, which prevent endogenous Notch activation, and confirmed these effects through creation and characterization of two different adipocyte-specific Notch loss-of-function mouse models through genetic ablation of the Notch transcriptional effector Rbp-Jk (A-Rbpj and the obligate γ-secretase component Nicastrin (A-Nicastrin. Methods: Glucose homeostasis and both local adipose and systemic insulin sensitivity were examined in GSI-treated, A-Rbpj and A-Nicastrin mice, as well as vehicle-treated or control littermates, with complementary in vitro studies in primary hepatocytes and 3T3-L1 adipocytes. Results: GSI-treatment increases hepatic insulin sensitivity in obese mice but leads to reciprocal lowering of adipose glucose disposal. While A-Rbpj mice show normal body weight, adipose development and mass and unchanged adipose insulin sensitivity as control littermates, A-Nicastrin mice are relatively insulin-resistant, mirroring the GSI effect on adipose insulin action. Conclusions: Notch signaling is dispensable for normal adipocyte function, but adipocyte-specific γ-secretase blockade reduces adipose insulin sensitivity, suggesting that specific Notch inhibitors would be preferable to GSIs for application in T2D. Keywords: Notch, γ-secretase complex, Insulin resistance

  8. Simulation of a method for determining one-dimensional {sup 137}Cs distribution using multiple gamma spectroscopic measurements with an adjustable cylindrical collimator and center shield

    Whetstone, Z.D.; Dewey, S.C. [Radiological Health Engineering Laboratory, Department of Nuclear Engineering and Radiological Sciences, University of Michigan, 2355 Bonisteel Boulevard, 1906 Cooley Building, Ann Arbor, MI 48109-2104 (United States); Kearfott, K.J., E-mail: kearfott@umich.ed [Radiological Health Engineering Laboratory, Department of Nuclear Engineering and Radiological Sciences, University of Michigan, 2355 Bonisteel Boulevard, 1906 Cooley Building, Ann Arbor, MI 48109-2104 (United States)

    2011-05-15

    With multiple in situ gamma spectroscopic measurements obtained with an adjustable cylindrical collimator and a circular shield, the arbitrary one-dimensional distribution of radioactive material can be determined. The detector responses are theoretically calculated, field measurements obtained, and a system of equations relating detector response to measurement geometry and activity distribution solved to estimate the distribution. This paper demonstrates the method by simulating multiple scenarios and providing analysis of the system conditioning.

  9. Semi-quantitative and simulation analyses of effects of {gamma} rays on determination of calibration factors of PET scanners with point-like {sup 22}Na sources

    Hasegawa, Tomoyuki [School of Allied Health Sciences, Kitasato University, 1-15-1, Kitasato, Minamiku, Sagamihara, Kanagawa, 252-0373 (Japan); Sato, Yasushi [National Institute of Advanced Industrial Science and Technology, 1-1-1, Umezono, Tsukuba, Ibaraki, 305-8568 (Japan); Oda, Keiichi [Tokyo Metropolitan Institute of Gerontology, 1-1, Nakamachi, Itabashi, Tokyo, 173-0022 (Japan); Wada, Yasuhiro [RIKEN Center for Molecular Imaging Science, 6-7-3, Minamimachi, Minatoshima, Chuo, Kobe, Hyogo, 650-0047 (Japan); Murayama, Hideo [National Institute of Radiological Sciences, 4-9-1, Anagawa, Inage, Chiba, 263-8555 (Japan); Yamada, Takahiro, E-mail: hasegawa@kitasato-u.ac.jp [Japan Radioisotope Association, 2-28-45, Komagome, Bunkyo-ku, Tokyo, 113-8941 (Japan)

    2011-09-21

    The uncertainty of radioactivity concentrations measured with positron emission tomography (PET) scanners ultimately depends on the uncertainty of the calibration factors. A new practical calibration scheme using point-like {sup 22}Na radioactive sources has been developed. The purpose of this study is to theoretically investigate the effects of the associated 1.275 MeV {gamma} rays on the calibration factors. The physical processes affecting the coincidence data were categorized in order to derive approximate semi-quantitative formulae. Assuming the design parameters of some typical commercial PET scanners, the effects of the {gamma} rays as relative deviations in the calibration factors were evaluated by semi-quantitative formulae and a Monte Carlo simulation. The relative deviations in the calibration factors were less than 4%, depending on the details of the PET scanners. The event losses due to rejecting multiple coincidence events of scattered {gamma} rays had the strongest effect. The results from the semi-quantitative formulae and the Monte Carlo simulation were consistent and were useful in understanding the underlying mechanisms. The deviations are considered small enough to correct on the basis of precise Monte Carlo simulation. This study thus offers an important theoretical basis for the validity of the calibration method using point-like {sup 22}Na radioactive sources.

  10. Are serum gamma-glutamyl transferase, high-sensitivity C-reactive protein, and ischaemia-modified albumin useful in diagnosing PCOS?

    Ozturk, Mustafa; Keskin, Ugur; Ozturk, Ozlem; Ulubay, Mustafa; Alanbay, İbrahim; Aydin, Aytekin; Yenen, Müfit Cemal

    2016-10-01

    We assessed the serum levels of gamma-glutamyl transferase (GGT), high-sensitivity C-reactive protein (hsCRP) and ischaemia-modified albumin (IMA) in patients with polycystic ovary syndrome (PCOS). Fifty-three patients with PCOS were included in our study along with 40 women with no PCOS as the control group. The patients were divided according to their body mass index (BMI). GGT levels were significantly higher in the women with PCOS than the women in the control group (p PCOS women who were normoweight and overweight than the normoweight and overweight women in the control group (p PCOS and the controls or between the normoweight and overweight subgroups. GGT may be associated with the diagnosis of PCOS when the threshold is set at >15.5 U/L. With the application of this threshold, raised GGT levels had 83% sensitivity (95% CI 0.70-0.90) and 67.5% specificity (95% CI 0.52-0.79), for the diagnosis of PCOS. In our study, GGT levels were elevated in the PCOS patients independent of BMI and could thus be an important marker of PCOS.

  11. Sensitivity of air pollution simulations with LOTOS-EUROS to temporal distribution of anthropogenic emissions

    Mues, A.; Kuenen, J.; Hendriks, C.; Manders, A.; Segers, A.; Scholz, Y.; Hueglin, C.; Builtjes, P.; Schaap, M.

    2013-07-01

    In this study the sensitivity of the model performance of the chemistry transport model (CTM) LOTOS-EUROS to the description of the temporal variability of emissions was investigated. Currently the temporal release of anthropogenic emissions is described by European average diurnal, weekly and seasonal time profiles per sector. These default time profiles largely neglect the variation of emission strength with activity patterns, region, species, emission process and meteorology. The three sources dealt with in this study are combustion in energy and transformation industries (SNAP1), non-industrial combustion (SNAP2) and road transport (SNAP7). First the impact of neglecting the temporal emission profiles for these SNAP categories on simulated concentrations was explored. In a~second step, we constructed more detailed emission time profiles for the three categories and quantified their impact on the model performance separately as well as combined. The performance in comparison to observations for Germany was quantified for the pollutants NO2, SO2 and PM10 and compared to a simulation using the default LOTOS-EUROS emission time profiles. In general the largest impact on the model performance was found when neglecting the default time profiles for the three categories. The daily average correlation coefficient for instance decreased by 0.04 (NO2), 0.11 (SO2) and 0.01 (PM10) at German urban background stations compared to the default simulation. A systematic increase of the correlation coefficient is found when using the new time profiles. The size of the increase depends on the source category, the component and station. Using national profiles for road transport showed important improvements of the explained variability over the weekdays as well as the diurnal cycle for NO2. The largest impact of the SNAP1 and 2 profiles were found for SO2. When using all new time profiles simultaneously in one simulation the daily average correlation coefficient increased by 0

  12. Optically stimulated luminescence sensitivity changes in quartz due to repeated use in single aliquot readout: experiments and computer simulations

    McKeever, S.W.S.; Oklahoma State Univ., Stillwater, OK; Boetter-Jensen, L.; Agersnap Larsen, N.; Mejdahl, V.; Poolton, N.R.J.

    1996-01-01

    As part of a study to examine sensitivity changes in single aliquot techniques using optically stimulated luminescence (OSL) a series of experiments has been conducted with single aliquots of natural quartz, and the data compared with the results of computer simulations of the type of processes believed to be occurring. The computer model used includes both shallow and deep ('hard-to-bleach') traps, OSL ('easy-to-bleach') traps, and radiative and non-radiative recombination centres. The model has previously been used successfully to account for sensitivity changes in quartz due to thermal annealing. The simulations are able to reproduce qualitatively the main features of the experimental results including sensitivity changes as a function of re-use, and their dependence upon bleaching time and laboratory dose. The sensitivity changes are believed to be the result of a combination of shallow trap and deep trap effects. (author)

  13. Optically stimulated luminescence sensitivity changes in quartz due to repeated use in single aliquot readout: Experiments and computer simulations

    McKeever, S.W.S.; Bøtter-Jensen, L.; Agersnap Larsen, N.

    1996-01-01

    believed to be occurring. The computer model used includes both shallow and deep ('hard-to-bleach') traps, OSL ('easy-to-bleach') traps, and radiative and non-radiative recombination centres. The model has previously been used successfully to account for sensitivity changes in quartz due to thermal......As part of a study to examine sensitivity changes in single aliquot techniques using optically stimulated luminescence (OSL) a series of experiments has been conducted with single aliquots of natural quartz, and the data compared with the results of computer simulations of the type of processes...... annealing. The simulations are able to reproduce qualitatively the main features of the experimental results including sensitivity changes as a function of reuse, and their dependence upon bleaching time and laboratory dose. The sensitivity changes are believed to be the result of a combination of shallow...

  14. Secondary gamma-ray skyshine from 14 MeV Neutron Source Facility (OKTAVIAN). Comparison of measurement with its simulation

    Morotomi, Ryutaro; Kondo, Tetsuo; Murata, Isao; Yoshida, Shigeo; Takahashi, Akito [Osaka Univ., Department of Nuclear Engineering, Suita, Osaka (Japan); Yamamoto, Takayoshi [Osaka Univ., Radio Isotope Research Center, Suita, Osaka (Japan)

    2000-03-01

    Measurement of secondary gamma-ray skyshine was performed at the Intense 14 MeV Neutron Source Facility (OKTAVIAN) of Osaka University with NaI and Hp-Ge detectors. From the result of measurements, some mechanism of secondary gamma-ray skyshine from 14 MeV neutron source facility was found out. The analysis of the measured result were carried out with MCNP-4B for four nuclear data files of JENDL-3.2, JENDL-F.F., FENDL-2, and ENDF/B-VI. It was confirmed that all the nuclear data are fairly reliable for calculations of secondary gamma-ray skyshine. (author)

  15. Monte Carlo simulation of gamma-ray interactions in an over-square high-purity germanium detector for in-vivo measurements

    Saizu, Mirela Angela

    2016-09-01

    The developments of high-purity germanium detectors match very well the requirements of the in-vivo human body measurements regarding the gamma energy ranges of the radionuclides intended to be measured, the shape of the extended radioactive sources, and the measurement geometries. The Whole Body Counter (WBC) from IFIN-HH is based on an “over-square” high-purity germanium detector (HPGe) to perform accurate measurements of the incorporated radionuclides emitting X and gamma rays in the energy range of 10 keV-1500 keV, under conditions of good shielding, suitable collimation, and calibration. As an alternative to the experimental efficiency calibration method consisting of using reference calibration sources with gamma energy lines that cover all the considered energy range, it is proposed to use the Monte Carlo method for the efficiency calibration of the WBC using the radiation transport code MCNP5. The HPGe detector was modelled and the gamma energy lines of 241Am, 57Co, 133Ba, 137Cs, 60Co, and 152Eu were simulated in order to obtain the virtual efficiency calibration curve of the WBC. The Monte Carlo method was validated by comparing the simulated results with the experimental measurements using point-like sources. For their optimum matching, the impact of the variation of the front dead layer thickness and of the detector photon absorbing layers materials on the HPGe detector efficiency was studied, and the detector’s model was refined. In order to perform the WBC efficiency calibration for realistic people monitoring, more numerical calculations were generated simulating extended sources of specific shape according to the standard man characteristics.

  16. Monte Carlo simulation of the Leksell Gamma Knife{sup TM}: II. Effects of heterogeneous versus homogeneous media for stereotactic radiosurgery

    Moskvin, Vadim; Timmerman, Robert; DesRosiers, Colleen; Randall, Marcus; DesRosiers, Paul; Dittmer, Phil; Papiez, Lech [Department of Radiation Oncology, Indiana University School of Medicine, Indianapolis, 535 Barnhill Dr, RT041, IN 46202-5289 (United States)

    2004-11-07

    The absence of electronic equilibrium in the vicinity of bone-tissue or air-tissue heterogeneity in the head can misrepresent deposited dose with treatment planning algorithms that assume all treatment volume as homogeneous media. In this paper, Monte Carlo simulation (PENELOPE) and measurements with a specially designed heterogeneous phantom were applied to investigate the effect of air-tissue and bone-tissue heterogeneity on dose perturbation with the Leksell Gamma Knife{sup TM}. The dose fall-off near the air-tissue interface caused by secondary electron disequilibrium leads to overestimation of dose by the vendor supplied treatment planning software (GammaPlan{sup TM}) at up to 4 mm from an interface. The dose delivered to the target area away from an air-tissue interface may be underestimated by up to 7% by GammaPlan{sup TM} due to overestimation of attenuation of photon beams passing through air cavities. While the underdosing near the air-tissue interface cannot be eliminated with any plug pattern, the overdosage due to under-attenuation of the photon beams in air cavities can be eliminated by plugging the sources whose beams intersect the air cavity. Little perturbation was observed next to bone-tissue interfaces. Monte Carlo results were confirmed by measurements. This study shows that the employed Monte Carlo treatment planning is more accurate for precise dosimetry of stereotactic radiosurgery with the Leksell Gamma Knife{sup TM} for targets in the vicinity of air-filled cavities.

  17. Transient simulation and sensitivity analysis for transport of radionuclides in a saturated-unsaturated groundwater flow system

    Chen, H.H.

    1980-01-01

    Radionuclide transport by groundwater flow is an important pathway in the assessment of the environmental impact of radioactive waste disposal to the biosphere. A numerical model was developed to simulate radionuclide transport by groundwater flow and predict the radionuclide discharge rate to the biosphere. A sensitivity analysis methodology was developed to address the sensitivity of the input parameters of the radionuclide transport equation to the specified response of interest

  18. Analysis of sensitivity of simulated recharge to selected parameters for seven watersheds modeled using the precipitation-runoff modeling system

    Ely, D. Matthew

    2006-01-01

    Recharge is a vital component of the ground-water budget and methods for estimating it range from extremely complex to relatively simple. The most commonly used techniques, however, are limited by the scale of application. One method that can be used to estimate ground-water recharge includes process-based models that compute distributed water budgets on a watershed scale. These models should be evaluated to determine which model parameters are the dominant controls in determining ground-water recharge. Seven existing watershed models from different humid regions of the United States were chosen to analyze the sensitivity of simulated recharge to model parameters. Parameter sensitivities were determined using a nonlinear regression computer program to generate a suite of diagnostic statistics. The statistics identify model parameters that have the greatest effect on simulated ground-water recharge and that compare and contrast the hydrologic system responses to those parameters. Simulated recharge in the Lost River and Big Creek watersheds in Washington State was sensitive to small changes in air temperature. The Hamden watershed model in west-central Minnesota was developed to investigate the relations that wetlands and other landscape features have with runoff processes. Excess soil moisture in the Hamden watershed simulation was preferentially routed to wetlands, instead of to the ground-water system, resulting in little sensitivity of any parameters to recharge. Simulated recharge in the North Fork Pheasant Branch watershed, Wisconsin, demonstrated the greatest sensitivity to parameters related to evapotranspiration. Three watersheds were simulated as part of the Model Parameter Estimation Experiment (MOPEX). Parameter sensitivities for the MOPEX watersheds, Amite River, Louisiana and Mississippi, English River, Iowa, and South Branch Potomac River, West Virginia, were similar and most sensitive to small changes in air temperature and a user-defined flow

  19. Compton scatter in germanium and its effect on imaging with gamma-ray position-sensitive detectors

    Sherman, I.S.; Strauss, M.G.; Brenner, R.

    1978-01-01

    The spatial spread due to Compton scatter in Ge was measured to study the reduction in image contrast and signal-to-noise ratio (S/N) resulting from erroneous readout in Ge position-sensitive detectors. The step response revealing this spread was obtained by scanning with a 122 keV γ-ray beam across a boundary of two sectors of a slotted coaxial Ge(Li) detector that is 40 mm diameter by 22 mm long. The derived line-spread function at 140 keV (/sup 99m/Tc) exhibits much shorter but thicker tails than those due to scatter in tissue as observed with a NaI detector through 5.5 cm of scattering material. Convolutions of rectangular profiles of voids with the Ge(Li) line-spread function show marked deterioration in contrast for voids less than 10 mm across, which in turn results in even greater deterioration of the S/N. As a result, the contrast for voids in Ge images is only 20 to 30 percent higher than that in NaI and the S/N is only comparable for equal detector areas. The degradation in image contrast due to scatter in Ge detectors can be greatly reduced by either using thin detectors (approximately 5 mm), where scatter virtually does not exist, or by using thicker detectors and rejecting scatter electronically. To reduce the effects of scatter on the S/N as well as on contrast, the erroneous position readouts must actually be corrected. A more realizable approach to achieving the ultimate potential of Ge detectors may be a scanning array of discrete detectors (not position sensitive) in which readout is not affected by scatter

  20. Sensitivity of the xerophytic moss Syntrichia caninervis to chronic simulated nitrogen deposition

    Zhang, Yuanming

    2016-04-01

    Biological soil crusts, complex of cyanobacteira, fungi, lichens and mosses, are common in dryland area and act as important elements of these ecosystems. Syntrichia caninervis is the dominant species in moss crusts in many desert ecosystems. Increasing N deposition has lead to great changes in community structure and function in the desert ecosystem worldwide. However, it is unclear how moss crusts respond to increased atmospheric N deposition, especially in term of growth and physiological parameters. The population and individual growth, and physiological responses of S. caninervis to six different doses of simulated N deposition (0, 0.3, 0.5, 1.0, 1.5 and 3.0 g N m-2 a-1) over three years were studied. Simulated N deposition in the Gurbantunggut Desert affected growth and physiological indices of the xerophytic moss S.caninervis. Low N addition increased individual plant length and leaf size. High N addition was detrimental to almost all growth characteristics monitored, although moss abundance was increased. The photosynthesis-related indices were moderately increased at low N addition rates and significantly decreased by high N addition. Changes in osmotic adjustment substance concentrations and activities of antioxidant enzymes facilitated protection of leaf cells from oxidative damage under N addition. Low rates of N additiondid not significantly affect, and may even stimulate growth and physiological activity of moss crusts. However, high rates of N addition decreased moss vitality and might affect the function of moss crusts. Moss crusts are sensitive to N addition and greater attention should be paid to protection of such kinds of biological complexes in desert ecosystems under increasing N deposition. Key words: antioxidant enzyme, chlorophyll, fluorescence, nitrogen deposition, osmotic substance, Syntrichia caninervis

  1. Numerical simulation and sensitivity study of a severe hailstorm in northeast Spain

    García-Ortega, E.; Fita, L.; Romero, R.; López, L.; Ramis, C.; Sánchez, J. L.

    2007-02-01

    During the afternoon of August 16th 2003 a severe hail event occurred in the town of Alcañiz in the Ebro Valley (Spain). This storm brought with it intense rain and hail precipitation that caused severe floods, damaged cars and street furniture. A diagnosis, using data from ECMWF, showed the presence of a mesolow at surface level centered over the Northeast of Spain, carrying winds from the Mediterranean Sea towards the Central Ebro Valley. At medium and high levels, a trough, whose axis extended over the Northwest of the Iberian Peninsula, moved eastwards preceded at 500 hPa by a thermal trough that caused increasing instability before the arrival of the geopotential trough. A numerical study of this event has been carried out using the MM5 model with a double aim. On the one hand, it attempts to check whether or not the simulation reproduces the storm in Alcañiz. On the other hand, it carries out a sensitivity experiment in order to evaluate the contribution of two specific factors: topography and solar radiation. Compared with radar data, the control simulation reproduces the region affected by the storm reasonably well. The suppression of topography and/or solar radiation substantially modifies the surface mesolow and the spatial distribution of the precipitation. Neither of these factors, considered independently, reproduces the precipitation caused by the storm in Alcañiz. However, the results illustrate the importance of the synergic effect of these two factors on the spatial localization of the storm and on the intensity of the precipitation registered.

  2. Sensitivity of simulated regional Arctic climate to the choice of coupled model domain

    Dmitry V. Sein

    2014-07-01

    Full Text Available The climate over the Arctic has undergone changes in recent decades. In order to evaluate the coupled response of the Arctic system to external and internal forcing, our study focuses on the estimation of regional climate variability and its dependence on large-scale atmospheric and regional ocean circulations. A global ocean–sea ice model with regionally high horizontal resolution is coupled to an atmospheric regional model and global terrestrial hydrology model. This way of coupling divides the global ocean model setup into two different domains: one coupled, where the ocean and the atmosphere are interacting, and one uncoupled, where the ocean model is driven by prescribed atmospheric forcing and runs in a so-called stand-alone mode. Therefore, selecting a specific area for the regional atmosphere implies that the ocean–atmosphere system can develop ‘freely’ in that area, whereas for the rest of the global ocean, the circulation is driven by prescribed atmospheric forcing without any feedbacks. Five different coupled setups are chosen for ensemble simulations. The choice of the coupled domains was done to estimate the influences of the Subtropical Atlantic, Eurasian and North Pacific regions on northern North Atlantic and Arctic climate. Our simulations show that the regional coupled ocean–atmosphere model is sensitive to the choice of the modelled area. The different model configurations reproduce differently both the mean climate and its variability. Only two out of five model setups were able to reproduce the Arctic climate as observed under recent climate conditions (ERA-40 Reanalysis. Evidence is found that the main source of uncertainty for Arctic climate variability and its predictability is the North Pacific. The prescription of North Pacific conditions in the regional model leads to significant correlation with observations, even if the whole North Atlantic is within the coupled model domain. However, the inclusion of the

  3. Use of calibration methodology of gamma cameras for the workers surveillance using a thyroid simulator; Uso de una metodologia de calibracion de camaras gamma para la vigilancia de trabajadores usando un simulador de tiroides

    Alfaro, M.; Molina, G.; Vazquez, R.; Garcia, O., E-mail: mercedes.alfaro@inin.gob.m [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2010-09-15

    In Mexico there are a significant number of nuclear medicine centers in operation. For what the accidents risk related to the transport and manipulation of open sources used in nuclear medicine can exist. The National Institute of Nuclear Research (ININ) has as objective to establish a simple and feasible methodology for the workers surveillance related with the field of the nuclear medicine. This radiological surveillance can also be applied to the public in the event of a radiological accident. To achieve this it intends to use the available equipment s in the nuclear medicine centers, together with the neck-thyroid simulators elaborated by the ININ to calibrate the gamma cameras. The gamma cameras have among their component elements that conform spectrometric systems like the employees in the evaluation of the internal incorporation for direct measurements, reason why, besides their use for diagnostic for image, they can be calibrated with anthropomorphic simulators and also with punctual sources for the quantification of the radionuclides activity distributed homogeneously in the human body, or located in specific organs. Inside the project IAEA-ARCAL-RLA/9/049-LXXVIII -Procedures harmonization of internal dosimetry- where 9 countries intervened (Argentina, Brazil, Colombia, Cuba, Chile, Mexico, Peru, Uruguay and Spain). It was developed a protocol of cameras gamma calibration for the determination in vivo of radionuclides. The protocol is the base to establish and integrated network in Latin America to attend in response to emergencies, using nuclear medicine centers of public hospitals of the region. The objective is to achieve the appropriate radiological protection of the workers, essential for the sure and acceptable radiation use, the radioactive materials and the nuclear energy. (Author)

  4. Gamma ray astronomy

    Fichtel, C.E.

    1975-01-01

    The first certain detection of celestial high energy gamma rays came from a satellite experiment flown on the third Orbiting Solar Observatory (OSO-111). A Gamma ray spark chamber telescope with substantively greater sensitivity and angular resolution (a few degrees) flown on the second Small Astronomy Satellite (SAS-II) has now provided a better picture of the gamma ray sky, and particularly the galactic plane and pulsars. This paper will summarize the present picture of gamma ray astronomy as it has developed at this conference from measurements made with experiments carried out on balloons, those remaining on the ground, and ones flown on satellites. (orig.) [de

  5. Radiation transport simulation in gamma irradiator systems using E G S 4 Monte Carlo code and dose mapping calculations based on point kernel technique

    Raisali, G.R.

    1992-01-01

    A series of computer codes based on point kernel technique and also Monte Carlo method have been developed. These codes perform radiation transport calculations for irradiator systems having cartesian, cylindrical and mixed geometries. The monte Carlo calculations, the computer code 'EGS4' has been applied to a radiation processing type problem. This code has been acompanied by a specific user code. The set of codes developed include: GCELLS, DOSMAPM, DOSMAPC2 which simulate the radiation transport in gamma irradiator systems having cylinderical, cartesian, and mixed geometries, respectively. The program 'DOSMAP3' based on point kernel technique, has been also developed for dose rate mapping calculations in carrier type gamma irradiators. Another computer program 'CYLDETM' as a user code for EGS4 has been also developed to simulate dose variations near the interface of heterogeneous media in gamma irradiator systems. In addition a system of computer codes 'PRODMIX' has been developed which calculates the absorbed dose in the products with different densities. validation studies of the calculated results versus experimental dosimetry has been performed and good agreement has been obtained

  6. Estimation of Compton Imager Using Single 3D Position-Sensitive LYSO Scintillator: Monte Carlo Simulation

    Lee, Taewoong; Lee, Hyounggun; Kim, Younghak; Lee, Wonho [Korea University, Seoul (Korea, Republic of)

    2017-07-15

    The performance of a Compton imager using a single three-dimensional position-sensitive LYSO scintillator detector was estimated using a Monte Carlo simulation. The Compton imager consisted of a single LYSO scintillator with a pixelized structure. The size of the scintillator and each pixel were 1.3 × 1.3 × 1.3 cm{sup 3} and 0.3 × 0.3 × 0.3 cm{sup 3}, respectively. The order of γ-ray interactions was determined based on the deposited energies in each detector. After the determination of the interaction sequence, various types of reconstruction algorithms such as simple back-projection, filtered back-projection, and list-mode maximum-likelihood expectation maximization (LM-MLEM) were applied and compared with each other in terms of their angular resolution and signal-tonoise ratio (SNR) for several γ-ray energies. The LM-MLEM reconstruction algorithm exhibited the best performance for Compton imaging in maintaining high angular resolution and SNR. The two sources of {sup 137}Cs (662 keV) could be distinguishable if they were more than 17 ◦ apart. The reconstructed Compton images showed the precise position and distribution of various radiation isotopes, which demonstrated the feasibility of the monitoring of nuclear materials in homeland security and radioactive waste management applications.

  7. Parallel replica dynamics method for bistable stochastic reaction networks: Simulation and sensitivity analysis

    Wang, Ting; Plecháč, Petr

    2017-12-01

    Stochastic reaction networks that exhibit bistable behavior are common in systems biology, materials science, and catalysis. Sampling of stationary distributions is crucial for understanding and characterizing the long-time dynamics of bistable stochastic dynamical systems. However, simulations are often hindered by the insufficient sampling of rare transitions between the two metastable regions. In this paper, we apply the parallel replica method for a continuous time Markov chain in order to improve sampling of the stationary distribution in bistable stochastic reaction networks. The proposed method uses parallel computing to accelerate the sampling of rare transitions. Furthermore, it can be combined with the path-space information bounds for parametric sensitivity analysis. With the proposed methodology, we study three bistable biological networks: the Schlögl model, the genetic switch network, and the enzymatic futile cycle network. We demonstrate the algorithmic speedup achieved in these numerical benchmarks. More significant acceleration is expected when multi-core or graphics processing unit computer architectures and programming tools such as CUDA are employed.

  8. Sensitivity analysis of Immersed Boundary Method simulations of fluid flow in dense polydisperse random grain packings

    Knight Chris

    2017-01-01

    Full Text Available Polydisperse granular materials are ubiquitous in nature and industry. Despite this, knowledge of the momentum coupling between the fluid and solid phases in dense saturated grain packings comes almost exclusively from empirical correlations [2–4, 8] with monosized media. The Immersed Boundary Method (IBM is a Computational Fluid Dynamics (CFD modelling technique capable of resolving pore scale fluid flow and fluid-particle interaction forces in polydisperse media at the grain scale. Validation of the IBM in the low Reynolds number, high concentration limit was performed by comparing simulations of flow through ordered arrays of spheres with the boundary integral results of Zick and Homsy [10]. Random grain packings were studied with linearly graded particle size distributions with a range of coefficient of uniformity values (Cu = 1.01, 1.50, and 2.00 at a range of concentrations (ϕ ∈ [0.396; 0.681] in order to investigate the influence of polydispersity on drag and permeability. The sensitivity of the IBM results to the choice of radius retraction parameter [1] was investigated and a comparison was made between the predicted forces and the widely used Ergun correlation [3].

  9. Parallel replica dynamics method for bistable stochastic reaction networks: Simulation and sensitivity analysis.

    Wang, Ting; Plecháč, Petr

    2017-12-21

    Stochastic reaction networks that exhibit bistable behavior are common in systems biology, materials science, and catalysis. Sampling of stationary distributions is crucial for understanding and characterizing the long-time dynamics of bistable stochastic dynamical systems. However, simulations are often hindered by the insufficient sampling of rare transitions between the two metastable regions. In this paper, we apply the parallel replica method for a continuous time Markov chain in order to improve sampling of the stationary distribution in bistable stochastic reaction networks. The proposed method uses parallel computing to accelerate the sampling of rare transitions. Furthermore, it can be combined with the path-space information bounds for parametric sensitivity analysis. With the proposed methodology, we study three bistable biological networks: the Schlögl model, the genetic switch network, and the enzymatic futile cycle network. We demonstrate the algorithmic speedup achieved in these numerical benchmarks. More significant acceleration is expected when multi-core or graphics processing unit computer architectures and programming tools such as CUDA are employed.

  10. Microbial contamination of the crude drugs ''Senna Leaf'' and their radiation sensitivity to gamma-ray irradiation

    Ohnishi, Tokuhiro; Okamoto, Shinichi; Taimatsu, Meiko; Kimura, Syojiro

    1998-01-01

    The numbers of microorganisms adhering to the crude drug ''Senna Leaf'' and radiation sensitivity of them were investigated. Total aetobic microbial counts of ten kinds of Senna Leaf were determined to be in the range from 10 3 to 10 4 CFU/g for bacteria and from 10 1 to 10 3 CFU/g for fungi. The orders of these values were higher than the synthetic compound. Most of survival curves obtained in this experiment were sigmoidal. The induction dose (ID) was obtained from the shoulder portion of each curve, the D 2 value was obtained from the gradient of the linear portion of each curve and the inactivation factor (IF) was calculated from the sigmoid curve. The average values of ID, D 2 and IF for bacteria were 2.9 kGy, 1.0 kGy and 8.1 kGy respectively. From this experiment, the average SD value required for attaining the contamination level provided by the USP Forum (total bacteria count <20/g) was estimated to be 6 kGy. The numbers of fungi becomes less than 10 CFU/g under this condition. (author)

  11. A multi-panel direction-sensitive gamma-ray detector for low-altitude radiological searches

    Becker, E.M.; Farsoni, A.T.

    2016-11-11

    A lightweight, low-cost multi-panel direction-sensitive radiation detector prototype has been developed at Oregon State University that is designed to be mounted on a small unmanned aerial system to autonomously search for radiation sources while flying close to the ground. The detection system comprises sixteen BGO-SiPM detector panels with an adjustable view angle, and signal outputs are processed in parallel in an FPGA. The minimum detectable activity was calculated to be 1.3 μCi of {sup 137}Cs at 1 m in under 60 s. The counting response of the detector panels were characterized and found to have 4.7% relative standard deviation, indicating good uniformity in overall design and assembly. The detector was also able to estimate the direction of a 12.3 μCi {sup 137}Cs source 100 cm from the device center with 2.3° accuracy in a 95% confidence width of 10.8° in 60 s.

  12. Simulation study on the behavior of X-rays and gamma rays in an inhomogeneous medium using the Monte Carlo technique

    Murase, Kenya; Kataoka, Masaaki; Kawamura, Masashi; Tamada, Shuji; Hamamoto, Ken

    1989-01-01

    A computer program based on the Monte Carlo technique was developed for the analysis of the behavior of X-rays and gamma rays in an inhomogeneous medium. The statistical weight of a photon was introduced and the survival biasing method was used for reducing the statistical error. This computer program has the mass energy absorption and attenuation coefficients for 69 tissues and organs as a database file, and can be applied to various cases of inhomogeneity. The simulation and experimental results of the central axis percent-depth dose in an inhomogeneous phantom were in good agreement. This computer program will be useful for analysis on the behavior of X-rays and gamma rays in an inhomogeneous medium consisting of various tissues and organs, not only in radiotherapy treatment planning but also in diagnostic radiology and in the field treating radiation protection. (author)

  13. Application of the Tikhonov regularization method to wind retrieval from scatterometer data I. Sensitivity analysis and simulation experiments

    Zhong Jian; Huang Si-Xun; Du Hua-Dong; Zhang Liang

    2011-01-01

    Scatterometer is an instrument which provides all-day and large-scale wind field information, and its application especially to wind retrieval always attracts meteorologists. Certain reasons cause large direction error, so it is important to find where the error mainly comes. Does it mainly result from the background field, the normalized radar cross-section (NRCS) or the method of wind retrieval? It is valuable to research. First, depending on SDP2.0, the simulated ‘true’ NRCS is calculated from the simulated ‘true’ wind through the geophysical model function NSCAT2. The simulated background field is configured by adding a noise to the simulated ‘true’ wind with the non-divergence constraint. Also, the simulated ‘measured’ NRCS is formed by adding a noise to the simulated ‘true’ NRCS. Then, the sensitivity experiments are taken, and the new method of regularization is used to improve the ambiguity removal with simulation experiments. The results show that the accuracy of wind retrieval is more sensitive to the noise in the background than in the measured NRCS; compared with the two-dimensional variational (2DVAR) ambiguity removal method, the accuracy of wind retrieval can be improved with the new method of Tikhonov regularization through choosing an appropriate regularization parameter, especially for the case of large error in the background. The work will provide important information and a new method for the wind retrieval with real data. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  14. Testing and Performance Validation of a Sensitive Gamma Ray Camera Designed for Radiation Detection and Decommissioning Measurements in Nuclear Facilities-13044

    Mason, John A.; Looman, Marc R.; Poundall, Adam J.; Towner, Antony C.N. [ANTECH, A. N. Technology Ltd., Unit 6, Thames Park, Wallingford, Oxfordshire, OX10 9TA (United Kingdom); Creed, Richard; Pancake, Daniel [Argonne National Laboratory, 9700 South Cass Avenue, Lemont, IL 60439 (United States)

    2013-07-01

    This paper describes the measurements, testing and performance validation of a sensitive gamma ray camera designed for radiation detection and quantification in the environment and decommissioning and hold-up measurements in nuclear facilities. The instrument, which is known as RadSearch, combines a sensitive and highly collimated LaBr{sub 3} scintillation detector with an optical (video) camera with controllable zoom and focus and a laser range finder in one detector head. The LaBr{sub 3} detector has a typical energy resolution of between 2.5% and 3% at the 662 keV energy of Cs-137 compared to that of NaI detectors with a resolution of typically 7% to 8% at the same energy. At this energy the tungsten shielding of the detector provides a shielding ratio of greater than 900:1 in the forward direction and 100:1 on the sides and from the rear. The detector head is mounted on a pan/tile mechanism with a range of motion of ±180 degrees (pan) and ±90 degrees (tilt) equivalent to 4 π steradians. The detector head with pan/tilt is normally mounted on a tripod or wheeled cart. It can also be mounted on vehicles or a mobile robot for access to high dose-rate areas and areas with high levels of contamination. Ethernet connects RadSearch to a ruggedized notebook computer from which it is operated and controlled. Power can be supplied either as 24-volts DC from a battery or as 50 volts DC supplied by a small mains (110 or 230 VAC) power supply unit that is co-located with the controlling notebook computer. In this latter case both power and Ethernet are supplied through a single cable that can be up to 80 metres in length. If a local battery supplies power, the unit can be controlled through wireless Ethernet. Both manual operation and automatic scanning of surfaces and objects is available through the software interface on the notebook computer. For each scan element making up a part of an overall scanned area, the unit measures a gamma ray spectrum. Multiple

  15. Testing and Performance Validation of a Sensitive Gamma Ray Camera Designed for Radiation Detection and Decommissioning Measurements in Nuclear Facilities-13044

    Mason, John A.; Looman, Marc R.; Poundall, Adam J.; Towner, Antony C.N.; Creed, Richard; Pancake, Daniel

    2013-01-01

    This paper describes the measurements, testing and performance validation of a sensitive gamma ray camera designed for radiation detection and quantification in the environment and decommissioning and hold-up measurements in nuclear facilities. The instrument, which is known as RadSearch, combines a sensitive and highly collimated LaBr 3 scintillation detector with an optical (video) camera with controllable zoom and focus and a laser range finder in one detector head. The LaBr 3 detector has a typical energy resolution of between 2.5% and 3% at the 662 keV energy of Cs-137 compared to that of NaI detectors with a resolution of typically 7% to 8% at the same energy. At this energy the tungsten shielding of the detector provides a shielding ratio of greater than 900:1 in the forward direction and 100:1 on the sides and from the rear. The detector head is mounted on a pan/tile mechanism with a range of motion of ±180 degrees (pan) and ±90 degrees (tilt) equivalent to 4 π steradians. The detector head with pan/tilt is normally mounted on a tripod or wheeled cart. It can also be mounted on vehicles or a mobile robot for access to high dose-rate areas and areas with high levels of contamination. Ethernet connects RadSearch to a ruggedized notebook computer from which it is operated and controlled. Power can be supplied either as 24-volts DC from a battery or as 50 volts DC supplied by a small mains (110 or 230 VAC) power supply unit that is co-located with the controlling notebook computer. In this latter case both power and Ethernet are supplied through a single cable that can be up to 80 metres in length. If a local battery supplies power, the unit can be controlled through wireless Ethernet. Both manual operation and automatic scanning of surfaces and objects is available through the software interface on the notebook computer. For each scan element making up a part of an overall scanned area, the unit measures a gamma ray spectrum. Multiple radionuclides may be

  16. Gamma teletopography

    Simonet, G.

    1987-06-01

    The mapping of gamma sources radiation emission in a nuclear plant is an important safety point. A remote gamma ray mapping process was developed in SPS/CEA/SACLAY. It uses the ''pinhole camera'' principle, precursor of photography. It mainly consists of a radiation proof box, with a small orifice, containing sensitive emulsions at the opposite. A first conventional photographic type emulsion photographs the area. A second photographic emulsion shows up the gamma radiations. The superim position of the two shots gives immediate informations of the precise location of each source of radiation in the observed area. To make easier the presentation and to improve the accuracy of the results for radiation levels mapping, the obtained films are digitally processed. The processing assigns a colours scale to the various levels of observed radiations. Taking account physical data and standard parameters, it gets possible to estimate the dose rate. The device is portable. Its compactness and fully independent nature make it suitable for use anywhere. It can be adapted to a remote automatic handling system, robot... so as to avoid all operator exposure when the local dose rate is too high [fr

  17. Measuring Cognitive Load during Simulation-Based Psychomotor Skills Training: Sensitivity of Secondary-Task Performance and Subjective Ratings

    Haji, Faizal A.; Khan, Rabia; Regehr, Glenn; Drake, James; de Ribaupierre, Sandrine; Dubrowski, Adam

    2015-01-01

    As interest in applying cognitive load theory (CLT) to the study and design of pedagogic and technological approaches in healthcare simulation grows, suitable measures of cognitive load (CL) are needed. Here, we report a two-phased study investigating the sensitivity of subjective ratings of mental effort (SRME) and secondary-task performance…

  18. Simulation of boundary layer trajectory dispersion sensitivity to soil moisture conditions: MM5 and noah-based investigation

    The sensitivity of trajectories from experiments in which volumetric values of soil moisture were changed with respect to control values were analyzed during three different synoptic episodes in June 2006. The MM5 and Noah land surface models were used to simulate the response of the planetary boun...

  19. Acceleration and sensitivity analysis of lattice kinetic Monte Carlo simulations using parallel processing and rate constant rescaling.

    Núñez, M; Robie, T; Vlachos, D G

    2017-10-28

    Kinetic Monte Carlo (KMC) simulation provides insights into catalytic reactions unobtainable with either experiments or mean-field microkinetic models. Sensitivity analysis of KMC models assesses the robustness of the predictions to parametric perturbations and identifies rate determining steps in a chemical reaction network. Stiffness in the chemical reaction network, a ubiquitous feature, demands lengthy run times for KMC models and renders efficient sensitivity analysis based on the likelihood ratio method unusable. We address the challenge of efficiently conducting KMC simulations and performing accurate sensitivity analysis in systems with unknown time scales by employing two acceleration techniques: rate constant rescaling and parallel processing. We develop statistical criteria that ensure sufficient sampling of non-equilibrium steady state conditions. Our approach provides the twofold benefit of accelerating the simulation itself and enabling likelihood ratio sensitivity analysis, which provides further speedup relative to finite difference sensitivity analysis. As a result, the likelihood ratio method can be applied to real chemistry. We apply our methodology to the water-gas shift reaction on Pt(111).

  20. Sensitivity to deliberate sea salt seeding of marine clouds – observations and model simulations

    K. Alterskjær

    2012-03-01

    Full Text Available Sea salt seeding of marine clouds to increase their albedo is a proposed technique to counteract or slow global warming. In this study, we first investigate the susceptibility of marine clouds to sea salt injections, using observational data of cloud droplet number concentration, cloud optical depth, and liquid cloud fraction from the MODIS (Moderate Resolution Imaging Spectroradiometer instruments on board the Aqua and Terra satellites. We then compare the derived susceptibility function to a corresponding estimate from the Norwegian Earth System Model (NorESM. Results compare well between simulations and observations, showing that stratocumulus regions off the west coast of the major continents along with large regions over the Pacific and the Indian Oceans are susceptible. At low and mid latitudes the signal is dominated by the cloud fraction.

    We then carry out geo-engineering experiments with a uniform increase over ocean of 10−9 kg m−2 s−1 in emissions of sea salt particles with a dry modal radius of 0.13 μm, an emission strength and areal coverage much greater than proposed in earlier studies. The increased sea salt concentrations and the resulting change in marine cloud properties lead to a globally averaged forcing of −4.8 W m−2 at the top of the atmosphere, more than cancelling the forcing associated with a doubling of CO2 concentrations. The forcing is large in areas found to be sensitive by using the susceptibility function, confirming its usefulness as an indicator of where to inject sea salt for maximum effect.

    Results also show that the effectiveness of sea salt seeding is reduced because the injected sea salt provides a large surface area for water vapor and gaseous sulphuric acid to condense on, thereby lowering the maximum supersaturation and suppressing the formation and lifetime of sulphate particles. In some areas, our simulations show an

  1. An analysis of MM5 sensitivity to different parameterizations for high-resolution climate simulations

    Argüeso, D.; Hidalgo-Muñoz, J. M.; Gámiz-Fortis, S. R.; Esteban-Parra, M. J.; Castro-Díez, Y.

    2009-04-01

    An evaluation of MM5 mesoscale model sensitivity to different parameterizations schemes is presented in terms of temperature and precipitation for high-resolution integrations over Andalusia (South of Spain). As initial and boundary conditions ERA-40 Reanalysis data are used. Two domains were used, a coarse one with dimensions of 55 by 60 grid points with spacing of 30 km and a nested domain of 48 by 72 grid points grid spaced 10 km. Coarse domain fully covers Iberian Peninsula and Andalusia fits loosely in the finer one. In addition to parameterization tests, two dynamical downscaling techniques have been applied in order to examine the influence of initial conditions on RCM long-term studies. Regional climate studies usually employ continuous integration for the period under survey, initializing atmospheric fields only at the starting point and feeding boundary conditions regularly. An alternative approach is based on frequent re-initialization of atmospheric fields; hence the simulation is divided in several independent integrations. Altogether, 20 simulations have been performed using varying physics options, of which 4 were fulfilled applying the re-initialization technique. Surface temperature and accumulated precipitation (daily and monthly scale) were analyzed for a 5-year period covering from 1990 to 1994. Results have been compared with daily observational data series from 110 stations for temperature and 95 for precipitation Both daily and monthly average temperatures are generally well represented by the model. Conversely, daily precipitation results present larger deviations from observational data. However, noticeable accuracy is gained when comparing with monthly precipitation observations. There are some especially conflictive subregions where precipitation is scarcely captured, such as the Southeast of the Iberian Peninsula, mainly due to its extremely convective nature. Regarding parameterization schemes performance, every set provides very

  2. Sensitivity analysis for CORSOR models simulating fission product release in LOFT-LP-FP-2 severe accident experiment

    Hoseyni, Seyed Mohsen [Islamic Azad Univ., Tehran (Iran, Islamic Republic of). Dept. of Basic Sciences; Islamic Azad Univ., Tehran (Iran, Islamic Republic of). Young Researchers and Elite Club; Pourgol-Mohammad, Mohammad [Sahand Univ. of Technology, Tabriz (Iran, Islamic Republic of). Dept. of Mechanical Engineering; Yousefpour, Faramarz [Nuclear Science and Technology Research Institute, Tehran (Iran, Islamic Republic of)

    2017-03-15

    This paper deals with simulation, sensitivity and uncertainty analysis of LP-FP-2 experiment of LOFT test facility. The test facility simulates the major components and system response of a pressurized water reactor during a LOCA. MELCOR code is used for predicting the fission product release from the core fuel elements in LOFT LP-FP-2 experiment. Moreover, sensitivity and uncertainty analysis is performed for different CORSOR models simulating release of fission products in severe accident calculations for nuclear power plants. The calculated values for the fission product release are compared under different modeling options to the experimental data available from the experiment. In conclusion, the performance of 8 CORSOR modeling options is assessed for available modeling alternatives in the code structure.

  3. Sensitivity of long-term bare soil infiltration simulations to hydraulic properties in an arid environment

    Stothoff, S.A.

    1997-01-01

    The suitability of Yucca Mountain, Nevada, for emplacement of a high-level nuclear waste geologic repository is currently being evaluated. Assessments of the repository performance suggest that the uncertainty in infiltration rates strongly affects predicted repository performance. Most of the ground surface over the potential repository footprint is characterized by shallow to deep colluvium/alluvium overlying densely fractured, welded tuffs. In order to identify characteristic behavior of infiltration that might be expected at the site, two idealizations of this situation are examined: an effectively semi-infinite column of alluvium and a two-layer column of alluvium over a fractured impermeable matrix. For each idealization the impact of hydraulic properties is assessed. Examining the sensitivity of bare soil simulator predictions for an effectively semi-infinite column, it is found that decreasing the air entry pressure while holding all other parameters at a fixed level tends to increase both the long-term average moisture content and the long-term average net infiltration flux for homogeneous media. In contrast, increasing the van Genuchten scale parameter (m = 1 - 1/n) or decreasing the porosity tends to decrease the average soil moisture but increase the infiltration. Most interestingly, three regimes are found for permeability. For relatively high permeabilities, there is a trend toward increasing average infiltration and increasing average moisture content with decreasing permeability. For relatively low permeabilities, vapor transport dominates over liquid transport, runoff and evaporation overwhelm infiltration, and the soil becomes very dry with essentially no infiltration flux Between the extreme cases of high and low permeability, there is a zone where decreasing permeability results in decreased infiltration but increased moisture content

  4. Sensitivity of ocean model simulation in the coastal ocean to the resolution of the meteorological forcing

    Chen, Feng; Shapiro, Georgy; Thain, Richard

    2013-04-01

    The quality of ocean simulations depends on a number of factors such as approximations in governing equations, errors introduced by the numerical scheme, uncertainties in input parameters, and atmospheric forcing. The identification of relations between the uncertainties in input and output data is still a challenge for the development of numerical models. The impacts of ocean variables on ocean models are still not well known (e.g., Kara et al., 2009). Given the considerable importance of the atmospheric forcing to the air-sea interaction, it is essential that researchers in ocean modelling work need a good understanding about how sensitive the atmospheric forcing is to variations of model results, which is beneficial to the development of ocean models. Also, it provides a proper way to choose the atmospheric forcing in ocean modelling applications. Our previous study (Shapiro et al, 2011) has shown that the basin-wide circulation pattern and the temperature structure in the Black Sea produced by the same model is significantly dependent on the source of the meteorological input, giving remarkably different responses. For the purpose of this study we have chosen the Celtic Sea where high resolution meteo data are available from the UK Met office since 2006. The Celtic Sea is tidally dominated water basin, with the tidal stream amplitude varying from 0.25m/s in the southwest to 2 m/s in the Bristol Channel. It is also filled with mesoscale eddies which contribute to the formation of the residual (tidally averaged) circulation pattern (Young et al, 2003). The sea is strongly stratified from April to November, which adds to the formation of density driven currents. In this paper we analyse how sensitive the model output is to variations in the spatial resolution of meteorological using low (1.6°) and high (0.11°) resolution meteo forcing, giving the quantitative relation between variations of met forcing and the resulted differences of model results, as well as

  5. Interpreting the gamma statistic in phylogenetic diversification rate studies: a rate decrease does not necessarily indicate an early burst.

    James A Fordyce

    Full Text Available BACKGROUND: Phylogenetic hypotheses are increasingly being used to elucidate historical patterns of diversification rate-variation. Hypothesis testing is often conducted by comparing the observed vector of branching times to a null, pure-birth expectation. A popular method for inferring a decrease in speciation rate, which might suggest an early burst of diversification followed by a decrease in diversification rate is the gamma statistic. METHODOLOGY: Using simulations under varying conditions, I examine the sensitivity of gamma to the distribution of the most recent branching times. Using an exploratory data analysis tool for lineages through time plots, tree deviation, I identified trees with a significant gamma statistic that do not appear to have the characteristic early accumulation of lineages consistent with an early, rapid rate of cladogenesis. I further investigated the sensitivity of the gamma statistic to recent diversification by examining the consequences of failing to simulate the full time interval following the most recent cladogenic event. The power of gamma to detect rate decrease at varying times was assessed for simulated trees with an initial high rate of diversification followed by a relatively low rate. CONCLUSIONS: The gamma statistic is extraordinarily sensitive to recent diversification rates, and does not necessarily detect early bursts of diversification. This was true for trees of various sizes and completeness of taxon sampling. The gamma statistic had greater power to detect recent diversification rate decreases compared to early bursts of diversification. Caution should be exercised when interpreting the gamma statistic as an indication of early, rapid diversification.

  6. Interpreting the gamma statistic in phylogenetic diversification rate studies: a rate decrease does not necessarily indicate an early burst.

    Fordyce, James A

    2010-07-23

    Phylogenetic hypotheses are increasingly being used to elucidate historical patterns of diversification rate-variation. Hypothesis testing is often conducted by comparing the observed vector of branching times to a null, pure-birth expectation. A popular method for inferring a decrease in speciation rate, which might suggest an early burst of diversification followed by a decrease in diversification rate is the gamma statistic. Using simulations under varying conditions, I examine the sensitivity of gamma to the distribution of the most recent branching times. Using an exploratory data analysis tool for lineages through time plots, tree deviation, I identified trees with a significant gamma statistic that do not appear to have the characteristic early accumulation of lineages consistent with an early, rapid rate of cladogenesis. I further investigated the sensitivity of the gamma statistic to recent diversification by examining the consequences of failing to simulate the full time interval following the most recent cladogenic event. The power of gamma to detect rate decrease at varying times was assessed for simulated trees with an initial high rate of diversification followed by a relatively low rate. The gamma statistic is extraordinarily sensitive to recent diversification rates, and does not necessarily detect early bursts of diversification. This was true for trees of various sizes and completeness of taxon sampling. The gamma statistic had greater power to detect recent diversification rate decreases compared to early bursts of diversification. Caution should be exercised when interpreting the gamma statistic as an indication of early, rapid diversification.

  7. Sensitivity Analysis of Different Shapes of a Plastic Optical Fiber-Based Immunosensor for Escherichia coli: Simulation and Experimental Results

    Domingos M. C. Rodrigues

    2017-12-01

    Full Text Available Conventional pathogen detection methods require trained personnel, specialized laboratories and can take days to provide a result. Thus, portable biosensors with rapid detection response are vital for the current needs for in-loco quality assays. In this work the authors analyze the characteristics of an immunosensor based on the evanescent field in plastic optical fibers with macro curvature by comparing experimental with simulated results. The work studies different shapes of evanescent-wave based fiber optic sensors, adopting a computational modeling to evaluate the probes with the best sensitivity. The simulation showed that for a U-Shaped sensor, the best results can be achieved with a sensor of 980 µm diameter by 5.0 mm in curvature for refractive index sensing, whereas the meander-shaped sensor with 250 μm in diameter with radius of curvature of 1.5 mm, showed better sensitivity for either bacteria and refractive index (RI sensing. Then, an immunosensor was developed, firstly to measure refractive index and after that, functionalized to detect Escherichia coli. Based on the results with the simulation, we conducted studies with a real sensor for RI measurements and for Escherichia coli detection aiming to establish the best diameter and curvature radius in order to obtain an optimized sensor. On comparing the experimental results with predictions made from the modelling, good agreements were obtained. The simulations performed allowed the evaluation of new geometric configurations of biosensors that can be easily constructed and that promise improved sensitivity.

  8. Sensitivity Analysis of Different Shapes of a Plastic Optical Fiber-Based Immunosensor for Escherichia coli: Simulation and Experimental Results.

    Rodrigues, Domingos M C; Lopes, Rafaela N; Franco, Marcos A R; Werneck, Marcelo M; Allil, Regina C S B

    2017-12-19

    Conventional pathogen detection methods require trained personnel, specialized laboratories and can take days to provide a result. Thus, portable biosensors with rapid detection response are vital for the current needs for in-loco quality assays. In this work the authors analyze the characteristics of an immunosensor based on the evanescent field in plastic optical fibers with macro curvature by comparing experimental with simulated results. The work studies different shapes of evanescent-wave based fiber optic sensors, adopting a computational modeling to evaluate the probes with the best sensitivity. The simulation showed that for a U-Shaped sensor, the best results can be achieved with a sensor of 980 µm diameter by 5.0 mm in curvature for refractive index sensing, whereas the meander-shaped sensor with 250 μm in diameter with radius of curvature of 1.5 mm, showed better sensitivity for either bacteria and refractive index (RI) sensing. Then, an immunosensor was developed, firstly to measure refractive index and after that, functionalized to detect Escherichia coli . Based on the results with the simulation, we conducted studies with a real sensor for RI measurements and for Escherichia coli detection aiming to establish the best diameter and curvature radius in order to obtain an optimized sensor. On comparing the experimental results with predictions made from the modelling, good agreements were obtained. The simulations performed allowed the evaluation of new geometric configurations of biosensors that can be easily constructed and that promise improved sensitivity.

  9. Effect of scatter media on small gamma camera imaging characteristics

    Ser, H. K.; Choi, Y.; Yim, K. C.

    2001-01-01

    Effect of scatter media materials and thickness, located between radioactivity and small gamma camera, on imaging characteristics was evaluated. The small gamma camera developed for breast imaging was consisted of collimator, NaI(TI) crystal (60x60x6 mm 3 ). PSPMT (position sensitive photomultiplier tube), NIMs and personal computer. Monte Carlo simulation was performed to evaluate the system sensitivity with different scatter media thickness (0∼8 cm) and materials (air and acrylie) with parallel hole collimator and diverging collimator. The sensitivity and spatial resolution was measured using the small gamma camera with the same condition applied to the simulation. Counts was decreased by 10% (air) and 54% (acrylic) with the parallel hole collimator and by 35% (air) and 63% (acrylic) with the diverging collimator. Spatial resolution was decreased as increasing the thickness of scatter media. This study substantiate the importance of a gamma camera positioning and the minimization of the distance between detector and target lesion in the clinical application of a gamma camera

  10. Population Studies of Radio and Gamma-Ray Pulsars

    Harding, Alice K; Gonthier, Peter; Coltisor, Stefan

    2004-01-01

    Rotation-powered pulsars are one of the most promising candidates for at least some of the 40-50 EGRET unidentified gamma-ray sources that lie near the Galactic plane. Since the end of the EGRO mission, the more sensitive Parkes Multibeam radio survey has detected mere than two dozen new radio pulsars in or near unidentified EGRET sources, many of which are young and energetic. These results raise an important question about the nature of radio quiescence in gamma-ray pulsars: is the non-detection of radio emission a matter of beaming or of sensitivity? The answer is very dependent on the geometry of the radio and gamma-ray beams. We present results of a population synthesis of pulsars in the Galaxy, including for the first time the full geometry of the radio and gamma-ray beams. We use a recent empirically derived model of the radio emission and luminosity, and a gamma-ray emission geometry and luminosity derived theoretically from pair cascades in the polar slot gap. The simulation includes characteristics of eight radio surveys of the Princeton catalog plus the Parkes MB survey. Our results indicate that EGRET was capable of detecting several dozen pulsars as point sources, with the ratio of radio-loud to radio-quiet gamma-ray pulsars increasing significantly to about ten to one when the Parkes Survey is included. Polar cap models thus predict that many of the unidentified EGRET sources could be radio-loud gamma- ray pulsars, previously undetected as radio pulsars due to distance, large dispersion and lack of sensitivity. If true, this would make gamma-ray telescopes a potentially more sensitive tool for detecting distant young neutron stars in the Galactic plane.

  11. Idealized WRF model sensitivity simulations of sea breeze types and their effects on offshore windfields

    C. J. Steele

    2013-01-01

    Full Text Available The behaviour and characteristics of the marine component of sea breeze cells have received little attention relative to their onshore counterparts. Yet there is a growing interest and dependence on the offshore wind climate from, for example, a wind energy perspective. Using idealized model experiments, we investigate the sea breeze circulation at scales which approximate to those of the southern North Sea, a region of major ongoing offshore wind farm development. We also contrast the scales and characteristics of the pure and the little known corkscrew and backdoor sea breeze types, where the type is pre-defined by the orientation of the synoptic scale flow relative to the shoreline. We find, crucially, that pure sea breezes, in contrast to corkscrew and backdoor types, can lead to substantial wind speed reductions offshore and that the addition of a second eastern coastline emphasises this effect through generation of offshore "calm zones". The offshore extent of all sea breeze types is found to be sensitive to both the influence of Coriolis acceleration and to the boundary layer scheme selected. These extents range, for example for a pure sea breeze produced in a 2 m s−1 offshore gradient wind, from 0 km to 21 km between the Mellor-Yamada-Nakanishi-Niino and the Yonsei State University schemes respectively. The corkscrew type restricts the development of a backdoor sea breeze on the opposite coast and is also capable of traversing a 100 km offshore domain even under high along-shore gradient wind speed (>15 m s−1 conditions. Realistic variations in sea surface skin temperature and initializing vertical thermodynamic profile do not significantly alter the resulting circulation, though the strengths of the simulated sea breezes are modulated if the effective land-sea thermal contrast is altered. We highlight how sea breeze impacts on circulation need to be

  12. A highly sensitive label-free electrochemical aptasensor for interferon-gamma detection based on graphene controlled assembly and nuclease cleavage-assisted target recycling amplification.

    Yan, Genping; Wang, Yonghong; He, Xiaoxiao; Wang, Kemin; Liu, Jinquan; Du, Yudan

    2013-06-15

    We report here a highly sensitive and label-free electrochemical aptasensing technology for detection of interferon-gamma (IFN-γ) based on graphene controlled assembly and enzyme cleavage-assisted target recycling amplification strategy. In this work, in the absence of IFN-γ, the graphene could not be assembled onto the 16-mercaptohexadecanoic acid (MHA) modified gold electrode because the IFN-γ binding aptamer was strongly adsorbed on the graphene due to the strong π-π interaction. Thus the electronic transmission was blocked (eT OFF). However, the presence of target IFN-γ and DNase I led to desorption of aptamer from the graphene surface and further cleavage of the aptamer, thereby releasing the IFN-γ. The released IFN-γ could then re-attack other aptamers on the graphene, resulting in the successive release of the aptamers from the graphene. At the same time, the "naked" graphene could be assembled onto the MHA modified gold electrode with hydrophobic interaction and π-conjunction, mediating the electron transfer between the electrode and the electroactive indicator. Then, measurable electrochemical signals were generated (eT ON), which was related to the concentration of the IFN-γ. By taking advantages of graphene and enzyme cleavage-assisted target recycling amplification, the developed label-free electrochemical aptasensing technology showed a linear response to concentration of IFN-γ range from 0.1 to 0.7 pM. The detection limit of IFN-γ was determined to be 0.065 pM. Moreover, this aptasensor shows good selectivity toward the target in the presence of other relevant proteins. Our strategy thus opens new opportunities for label-free and amplified detection of other kinds of proteins. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. CONNECTING GRBs AND ULIRGs: A SENSITIVE, UNBIASED SURVEY FOR RADIO EMISSION FROM GAMMA-RAY BURST HOST GALAXIES AT 0 < z < 2.5

    Perley, D. A. [Department of Astronomy, California Institute of Technology, MC 249-17, 1200 East California Boulevard, Pasadena, CA 91125 (United States); Perley, R. A. [National Radio Astronomy Observatory, P.O. Box O, Socorro, NM 87801 (United States); Hjorth, J.; Malesani, D. [Dark Cosmology Centre, Niels Bohr Institute, DK-2100 Copenhagen (Denmark); Michałowski, M. J. [Scottish Universities Physics Alliance, Institute for Astronomy, University of Edinburgh, Royal Observatory, Edinburgh, EH9 3HJ (United Kingdom); Cenko, S. B. [NASA/Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Jakobsson, P. [Centre for Astrophysics and Cosmology, Science Institute, University of Iceland, Dunhagi 5, 107 Reykjavík (Iceland); Krühler, T. [European Southern Observatory, Alonso de Córdova 3107, Vitacura, Casilla 19001, Santiago 19 (Chile); Levan, A. J. [Department of Physics, University of Warwick, Coventry CV4 7AL (United Kingdom); Tanvir, N. R., E-mail: dperley@astro.caltech.edu [Department of Physics and Astronomy, University of Leicester, Leicester LE1 7RH (United Kingdom)

    2015-03-10

    Luminous infrared galaxies and submillimeter galaxies contribute significantly to stellar mass assembly and provide an important test of the connection between the gamma-ray burst (GRB) rate and that of overall cosmic star formation. We present sensitive 3 GHz radio observations using the Karl G. Jansky Very Large Array of 32 uniformly selected GRB host galaxies spanning a redshift range from 0 < z < 2.5, providing the first fully dust- and sample-unbiased measurement of the fraction of GRBs originating from the universe's most bolometrically luminous galaxies. Four galaxies are detected, with inferred radio star formation rates (SFRs) ranging between 50 and 300 M {sub ☉} yr{sup –1}. Three of the four detections correspond to events consistent with being optically obscured 'dark' bursts. Our overall detection fraction implies that between 9% and 23% of GRBs between 0.5 < z < 2.5 occur in galaxies with S {sub 3GHz} > 10 μJy, corresponding to SFR > 50 M {sub ☉} yr{sup –1} at z ∼ 1 or >250 M {sub ☉} yr{sup –1} at z ∼ 2. Similar galaxies contribute approximately 10%-30% of all cosmic star formation, so our results are consistent with a GRB rate that is not strongly biased with respect to the total SFR of a galaxy. However, all four radio-detected hosts have stellar masses significantly lower than IR/submillimeter-selected field galaxies of similar luminosities. We suggest that the GRB rate may be suppressed in metal-rich environments but independently enhanced in intense starbursts, producing a strong efficiency dependence on mass but little net dependence on bulk galaxy SFR.

  14. SU-E-T-563: Multi-Fraction Stereotactic Radiosurgery with Extend System of Gamma Knife: Treatment Verification Using Indigenously Designed Patient Simulating Multipurpose Phantom

    Bisht, R; Kale, S; Gopishankar, N; Rath, G; Julka, P; Agarwal, D; Singh, M; Garg, A; Kumar, P; Thulkar, S; Sharma, B [All India Institute of Medical Sciences, New Delhi (India)

    2015-06-15

    Purpose: Aim of the study is to evaluate mechanical and radiological accuracy of multi-fraction regimen and validate Gamma knife based fractionation using newly developed patient simulating multipurpose phantom. Methods: A patient simulating phantom was designed to verify fractionated treatments with extend system (ES) of Gamma Knife however it could be used to validate other radiotherapy procedures as well. The phantom has options to insert various density material plugs and mini CT/MR distortion phantoms to analyze the quality of stereotactic imaging. An additional thorax part designed to predict surface doses at various organ sites. The phantom was positioned using vacuum head cushion and patient control unit for imaging and treatment. The repositioning check tool (RCT) was used to predict phantom positioning under ES assembly. The phantom with special inserts for film in axial, coronal and sagittal plane were scanned with X-Ray CT and the acquired images were transferred to treatment planning system (LGP 10.1). The focal precession test was performed with 4mm collimator and an experimental plan of four 16mm collimator shots was prepared for treatment verification of multi-fraction regimen. The prescription dose of 5Gy per fraction was delivered in four fractions. Each fraction was analyzed using EBT3 films scanned with EPSON 10000XL Scanner. Results: The measurement of 38 RCT points showed an overall positional accuracy of 0.28mm. The mean deviation of 0.28% and 0.31 % were calculated as CT and MR image distortion respectively. The radiological focus accuracy test showed its deviation from mechanical center point of 0.22mm. The profile measurement showed close agreement between TPS planned and film measured dose. At tolerance criteria of 1%/1mm gamma index analysis showed a pass rate of > 95%. Conclusion: Our results show that the newly developed multipurpose patient simulating phantom is highly suitable for the verification of fractionated stereotactic

  15. Modular gamma systems

    Millegan, D.R.; Nixon, K.V.

    1982-01-01

    Nuclear safeguards requires sensitive, easily operated instruments for rapid inspection of personnel and vehicles to ensure that no uranium or plutonium is being diverted. Two portable gamma-ray detection systems have been developed. The Modular Gamma System (MGS) is very sensitive and two or more systems can be connected for even better performance. The multiunit configuration can be deployed by motor vehicle for search of large areas too extensive to search on foot. The Programmable Rate Monitor (PRM) is less sensitive but much smaller and therefore is more suitable for search of vehicles, personnel, or smaller areas. The PRM is programmable, which implements measurement and alarm algorithms for individual applications

  16. Global sensitivity analysis using emulators, with an example analysis of large fire plumes based on FDS simulations

    Kelsey, Adrian [Health and Safety Laboratory, Harpur Hill, Buxton (United Kingdom)

    2015-12-15

    Uncertainty in model predictions of the behaviour of fires is an important issue in fire safety analysis in nuclear power plants. A global sensitivity analysis can help identify the input parameters or sub-models that have the most significant effect on model predictions. However, to perform a global sensitivity analysis using Monte Carlo sampling might require thousands of simulations to be performed and therefore would not be practical for an analysis based on a complex fire code using computational fluid dynamics (CFD). An alternative approach is to perform a global sensitivity analysis using an emulator. Gaussian process emulators can be built using a limited number of simulations and once built a global sensitivity analysis can be performed on an emulator, rather than using simulations directly. Typically reliable emulators can be built using ten simulations for each parameter under consideration, therefore allowing a global sensitivity analysis to be performed, even for a complex computer code. In this paper we use an example of a large scale pool fire to demonstrate an emulator based approach to global sensitivity analysis. In that work an emulator based global sensitivity analysis was used to identify the key uncertain model inputs affecting the entrainment rates and flame heights in large Liquefied Natural Gas (LNG) fire plumes. The pool fire simulations were performed using the Fire Dynamics Simulator (FDS) software. Five model inputs were varied: the fire diameter, burn rate, radiative fraction, computational grid cell size and choice of turbulence model. The ranges used for these parameters in the analysis were determined from experiment and literature. The Gaussian process emulators used in the analysis were created using 127 FDS simulations. The emulators were checked for reliability, and then used to perform a global sensitivity analysis and uncertainty analysis. Large-scale ignited releases of LNG on water were performed by Sandia National

  17. Sensitivity study of surface wind flow of a limited area model simulating the extratropical storm Delta affecting the Canary Islands

    C. Marrero

    2009-04-01

    Full Text Available In November 2005 an extratropical storm named Delta affected the Canary Islands (Spain. The high sustained wind and intense gusts experienced caused significant damage. A numerical sensitivity study of Delta was conducted using the Weather Research & Forecasting Model (WRF-ARW. A total of 27 simulations were performed. Non-hydrostatic and hydrostatic experiments were designed taking into account physical parameterizations and geometrical factors (size and position of the outer domain, definition or not of nested grids, horizontal resolution and number of vertical levels. The Factor Separation Method was applied in order to identify the major model sensitivity parameters under this unusual meteorological situation. Results associated to percentage changes relatives to a control run simulation demonstrated that boundary layer and surface layer schemes, horizontal resolutions, hydrostaticity option and nesting grid activation were the model configuration parameters with the greatest impact on the 48 h maximum 10 m horizontal wind speed solution.

  18. Use of a solar panel as a directionally sensitive large-area radiation monitor for direct and scattered x-rays and gamma-rays.

    Abdul-Majid, S

    1987-01-01

    The characteristics of a 25.4 X 91 cm solar cell panel used as an x-ray and gamma-ray radiation monitor are presented. Applications for monitoring the primary x-ray beam are described at different values of operating currents and voltages as well as for directional dependence of scattered radiation. Other applications in gamma-ray radiography are also given. The detector showed linear response to both x-ray and gamma-ray exposures. The equipment is rigid, easy to use, relatively inexpensive and requires no power supply or any complex electronic equipment.

  19. Simulation-Based Stochastic Sensitivity Analysis of a Mach 4.5 Mixed-Compression Intake Performance

    Kato, H.; Ito, K.

    2009-01-01

    A sensitivity analysis of a supersonic mixed-compression intake of a variable-cycle turbine-based combined cycle (TBCC) engine is presented. The TBCC engine is de- signed to power a long-range Mach 4.5 transport capable of antipodal missions studied in the framework of an EU FP6 project, LAPCAT. The nominal intake geometry was designed using DLR abpi cycle analysis pro- gram by taking into account various operating require- ments of a typical mission profile. The intake consists of two movable external compression ramps followed by an isolator section with bleed channel. The compressed air is then diffused through a rectangular-to-circular subsonic diffuser. A multi-block Reynolds-averaged Navier- Stokes (RANS) solver with Srinivasan-Tannehill equilibrium air model was used to compute the total pressure recovery and mass capture fraction. While RANS simulation of the nominal intake configuration provides more realistic performance characteristics of the intake than the cycle analysis program, the intake design must also take into account in-flight uncertainties for robust intake performance. In this study, we focus on the effects of the geometric uncertainties on pressure recovery and mass capture fraction, and propose a practical approach to simulation-based sensitivity analysis. The method begins by constructing a light-weight analytical model, a radial-basis function (RBF) network, trained via adaptively sampled RANS simulation results. Using the RBF network as the response surface approximation, stochastic sensitivity analysis is performed using analysis of variance (ANOVA) technique by Sobol. This approach makes it possible to perform a generalized multi-input- multi-output sensitivity analysis based on high-fidelity RANS simulation. The resulting Sobol's influence indices allow the engineer to identify dominant parameters as well as the degree of interaction among multiple parameters, which can then be fed back into the design cycle.

  20. Sensitivity study of surface wind flow of a limited area model simulating the extratropical storm Delta affecting the Canary Islands

    Marrero, C.; Jorba, O.; Cuevas, E.; Baldasano, J. M.

    2009-01-01

    In November 2005 an extratropical storm named Delta affected the Canary Islands (Spain). The high sustained wind and intense gusts experienced caused significant damage. A numerical sensitivity study of Delta was conducted using the Weather Research & Forecasting Model (WRF-ARW). A total of 27 simulations were performed. Non-hydrostatic and hydrostatic experiments were designed taking into account physical parameterizations and geometrical factors (size and position of the outer domain, d...

  1. Using Simulation Module, PCLAB, for Steady State Disturbance Sensitivity Analysis in Process Control

    Ali, Emad; Idriss, Arimiyawo

    2009-01-01

    Recently, chemical engineering education moves towards utilizing simulation soft wares to enhance the learning process especially in the field of process control. These training simulators provide interactive learning through visualization and practicing which will bridge the gap between the theoretical abstraction of textbooks and the…

  2. Uncertainty and sensitivity analysis in building performance simulation for decision support and design optimization

    Hopfe, C.J.

    2009-01-01

    Building performance simulation (BPS) uses computer-based models that cover performance aspects such as energy consumption and thermal comfort in buildings. The uptake of BPS in current building design projects is limited. Although there is a large number of building simulation tools available, the

  3. A new measurement-while-drilling gamma ray log calibrator

    Meisner, J.; Brooks, A.; Wisniewski, W.

    1985-01-01

    Many of the present methods of calibration for both wireline and MWD gamma ray detectors use a point source at a fixed distance from the detector. MWD calibration errors are introduced from scattering effects, from spectral differences, from position sensitivity and form lack of cylindrical geometry. A new method has been developed at Exploration Logging INc. (EXLOG) that eliminates these errors. The method uses a wrap-around or annular calibrator, referenced to the University of Houston gamma ray API pit. The new calibrator is designed to simulate the API pit's gamma ray emission spectrum with a finite amount of natural source material in the annular shape. Because of the thickness of steel between the MWD gamma ray detector and the formation, there is theoretical necessity for spectral matching. A simple theoretical approach was used to calibrate the new calibrator. Spectral matching allows a closer approximation to wireline logs and makes it possible to estimate the relative spectral content of a formation

  4. Development of an airborne gamma radiation system for snow surveys

    Fritzsche, A E [EG and G, Inc., Las Vegas, NV (USA)

    1979-01-01

    An airborne gamma-snow survey system requires detailed design to obtain maximum precision and accuracy. The use of NaI(Te) gamma detectors with a full gamma energy spectrum pulse height analyzer together with a small computer provide a self-contained and flexible system. The dual detector method determines atmospheric radon perturbations in the detection system. Detailed calibration experiments must be performed to determine twenty parameters that describe the physical nature of the system. Multiple high altitude and lake flights are used to obtain background components. Simulation pads, loaded with varying concentrations of /sup 40/K, /sup 232/Th and /sup 23/..gamma..U yield photopeak stripping coefficients and basic system sensitivity. Multiple altitude flights over land lines provide air attenuation coefficients which may converted to water attenuation coefficients.

  5. Hybrid Reynolds-Averaged/Large Eddy Simulation of a Cavity Flameholder; Assessment of Modeling Sensitivities

    Baurle, R. A.

    2015-01-01

    Steady-state and scale-resolving simulations have been performed for flow in and around a model scramjet combustor flameholder. The cases simulated corresponded to those used to examine this flowfield experimentally using particle image velocimetry. A variety of turbulence models were used for the steady-state Reynolds-averaged simulations which included both linear and non-linear eddy viscosity models. The scale-resolving simulations used a hybrid Reynolds-averaged / large eddy simulation strategy that is designed to be a large eddy simulation everywhere except in the inner portion (log layer and below) of the boundary layer. Hence, this formulation can be regarded as a wall-modeled large eddy simulation. This effort was undertaken to formally assess the performance of the hybrid Reynolds-averaged / large eddy simulation modeling approach in a flowfield of interest to the scramjet research community. The numerical errors were quantified for both the steady-state and scale-resolving simulations prior to making any claims of predictive accuracy relative to the measurements. The steady-state Reynolds-averaged results showed a high degree of variability when comparing the predictions obtained from each turbulence model, with the non-linear eddy viscosity model (an explicit algebraic stress model) providing the most accurate prediction of the measured values. The hybrid Reynolds-averaged/large eddy simulation results were carefully scrutinized to ensure that even the coarsest grid had an acceptable level of resolution for large eddy simulation, and that the time-averaged statistics were acceptably accurate. The autocorrelation and its Fourier transform were the primary tools used for this assessment. The statistics extracted from the hybrid simulation strategy proved to be more accurate than the Reynolds-averaged results obtained using the linear eddy viscosity models. However, there was no predictive improvement noted over the results obtained from the explicit

  6. Comparing sensitivity and count rate performance of small-bore DOI-PET scanners by computer simulation

    Kobayashi, Tetsuya; Takahashi, Hisashi; Yamaya, Taiga; Murayama, Hideo; Kitamura, Keishi; Hasegawa, Tomoyuki; Suga, Mikio

    2006-01-01

    In the development of a dedicated small-bore DOI-PET scanner for small animals (jPET-RD), we performed Monte Carlo simulations using the GATE based on Geant4 and investigated the influence of the proximity of the detectors to the target object on the sensitivity and count rate performance. The jPET-RD is based on a large-size depth-of-interaction (DOI) block detector that consists of a 4-layered array of 32 x 32 LSO crystals (1.4 mm x 1.4 mm x 4.5 mm) and a 256-ch flat panel position-sensitive photomultiplier tube. In this work, three detector geometries were simulated: two rings of six detector blocks arranged in a hexagonal pattern (FOV 85 mm in diameter) and four detector blocks arranged in a tetragonal pattern (FOV 49 mm in diameter) and in an overlapped tetragonal pattern (FOV 38 mm in diameter). The simulation results showed that the smaller bore geometry can provide higher sensitivity because of its larger solid angle. Although it clearly affected the noise equivalent count rate (NECR) due to its high dead-time, parallel readout with appropriate anode segmentation improved the NECR at 20 MBq by a factor of 1.1 to 1.4 compared with the case of 256-ch anodes read out by one front-end circuit. (author)

  7. Parameterization and Sensitivity Analysis of a Complex Simulation Model for Mosquito Population Dynamics, Dengue Transmission, and Their Control

    Ellis, Alicia M.; Garcia, Andres J.; Focks, Dana A.; Morrison, Amy C.; Scott, Thomas W.

    2011-01-01

    Models can be useful tools for understanding the dynamics and control of mosquito-borne disease. More detailed models may be more realistic and better suited for understanding local disease dynamics; however, evaluating model suitability, accuracy, and performance becomes increasingly difficult with greater model complexity. Sensitivity analysis is a technique that permits exploration of complex models by evaluating the sensitivity of the model to changes in parameters. Here, we present results of sensitivity analyses of two interrelated complex simulation models of mosquito population dynamics and dengue transmission. We found that dengue transmission may be influenced most by survival in each life stage of the mosquito, mosquito biting behavior, and duration of the infectious period in humans. The importance of these biological processes for vector-borne disease models and the overwhelming lack of knowledge about them make acquisition of relevant field data on these biological processes a top research priority. PMID:21813844

  8. Sensitivity analysis for thermo-hydraulics model of a Westinghouse type PWR. Verification of the simulation results

    Farahani, Aref Zarnooshe [Islamic Azad Univ., Tehran (Iran, Islamic Republic of). Dept. of Nuclear Engineering, Science and Research Branch; Yousefpour, Faramarz [Nuclear Science and Technology Research Institute, Tehran (Iran, Islamic Republic of); Hoseyni, Seyed Mohsen [Islamic Azad Univ., Tehran (Iran, Islamic Republic of). Dept. of Basic Sciences; Islamic Azad Univ., Tehran (Iran, Islamic Republic of). Young Researchers and Elite Club

    2017-07-15

    Development of a steady-state model is the first step in nuclear safety analysis. The developed model should be qualitatively analyzed first, then a sensitivity analysis is required on the number of nodes for models of different systems to ensure the reliability of the obtained results. This contribution aims to show through sensitivity analysis, the independence of modeling results to the number of nodes in a qualified MELCOR model for a Westinghouse type pressurized power plant. For this purpose, and to minimize user error, the nuclear analysis software, SNAP, is employed. Different sensitivity cases were developed by modification of the existing model and refinement of the nodes for the simulated systems including steam generators, reactor coolant system and also reactor core and its connecting flow paths. By comparing the obtained results to those of the original model no significant difference is observed which is indicative of the model independence to the finer nodes.

  9. Seizure-induced alterations in fast-spiking basket cell GABA currents modulate frequency and coherence of gamma oscillation in network simulations

    Proddutur, Archana; Yu, Jiandong; Elgammal, Fatima S. [Department of Neurology and Neurosciences, New Jersey Medical School, Rutgers, Newark, New Jersey 07103 (United States); Santhakumar, Vijayalakshmi, E-mail: santhavi@njms.rutgers.edu [Department of Neurology and Neurosciences, New Jersey Medical School, Rutgers, Newark, New Jersey 07103 (United States); Department of Pharmacology and Physiology, New Jersey Medical School, Rutgers, Newark, New Jersey 07103 (United States)

    2013-12-15

    FS-BC frequency when E{sub GABA} was depolarizing (−54 mV). When FS-BCs were activated by biologically based dendritic synaptic inputs, enhancing g{sub GABA-extra} reduced the frequency and coherence of FS-BC firing when E{sub GABA} was shunting and increased average FS-BC firing when E{sub GABA} was depolarizing. Shifting E{sub GABA} from shunting to depolarizing potentials consistently increased network frequency to and above high gamma frequencies (>80 Hz). Since gamma oscillations may contribute to learning and memory processing [Fell et al., Nat. Neurosci. 4, 1259 (2001); Jutras et al., J. Neurosci. 29, 12521 (2009); Wang, Physiol. Rev. 90, 1195 (2010)], our demonstration that network oscillations are modulated by extrasynaptic inhibition in FS-BCs suggests that neuroactive compounds that act on extrasynaptic GABA receptors could impact memory formation by modulating hippocampal gamma oscillations. The simulation results indicate that the depolarized FS-BC GABA reversal, observed after experimental seizures, together with enhanced spillover extrasynaptic GABA currents are likely to promote generation of focal high frequency activity associated with epileptic networks.

  10. Seizure-induced alterations in fast-spiking basket cell GABA currents modulate frequency and coherence of gamma oscillation in network simulations

    Proddutur, Archana; Yu, Jiandong; Elgammal, Fatima S.; Santhakumar, Vijayalakshmi

    2013-01-01

    was depolarizing (−54 mV). When FS-BCs were activated by biologically based dendritic synaptic inputs, enhancing g GABA-extra reduced the frequency and coherence of FS-BC firing when E GABA was shunting and increased average FS-BC firing when E GABA was depolarizing. Shifting E GABA from shunting to depolarizing potentials consistently increased network frequency to and above high gamma frequencies (>80 Hz). Since gamma oscillations may contribute to learning and memory processing [Fell et al., Nat. Neurosci. 4, 1259 (2001); Jutras et al., J. Neurosci. 29, 12521 (2009); Wang, Physiol. Rev. 90, 1195 (2010)], our demonstration that network oscillations are modulated by extrasynaptic inhibition in FS-BCs suggests that neuroactive compounds that act on extrasynaptic GABA receptors could impact memory formation by modulating hippocampal gamma oscillations. The simulation results indicate that the depolarized FS-BC GABA reversal, observed after experimental seizures, together with enhanced spillover extrasynaptic GABA currents are likely to promote generation of focal high frequency activity associated with epileptic networks

  11. Simulation studies to determine the gamma radiation dose due to natural radioactivity in construction materials in dwellings

    Shetty, P.G.; Chougaonkar, M.P.; Mayya, Y.S.; Puranik, V.D.

    2008-01-01

    Gamma radiation dose is imparted to the living due to the natural radionuclides present in the environmental materials, including the building materials used for construction of dwellings. The radionuclides responsible for natural radiation dose are the primordial radionuclides of 232 Th, 238 U series and the 40 K. These nuclides together with their daughters give rise to external gamma ray dose as well as the inhalation doses arising from the short-lived radon/thoron gases and their progenies that are exhaled from the walls of the construction materials. The radioactivity inside a room and the radiation dose caused by it mainly depends on the concentration of the above mentioned radionuclides in the building materials and type/properties like thickness, density etc. of the material used for construction. A computational model for a standard house (without windows and door) has been designed using Monte Carlo N-particle code (MCNP). The code works on probability theory. The present paper discusses the individual contribution of doses from 40 K, uranium and thorium series. Further variation in the gamma doses due to different building materials and densities are also discussed. (author)

  12. Sensitivity Analysis of an ENteric Immunity SImulator (ENISI)-Based Model of Immune Responses to Helicobacter pylori Infection.

    Alam, Maksudul; Deng, Xinwei; Philipson, Casandra; Bassaganya-Riera, Josep; Bisset, Keith; Carbo, Adria; Eubank, Stephen; Hontecillas, Raquel; Hoops, Stefan; Mei, Yongguo; Abedi, Vida; Marathe, Madhav

    2015-01-01

    Agent-based models (ABM) are widely used to study immune systems, providing a procedural and interactive view of the underlying system. The interaction of components and the behavior of individual objects is described procedurally as a function of the internal states and the local interactions, which are often stochastic in nature. Such models typically have complex structures and consist of a large number of modeling parameters. Determining the key modeling parameters which govern the outcomes of the system is very challenging. Sensitivity analysis plays a vital role in quantifying the impact of modeling parameters in massively interacting systems, including large complex ABM. The high computational cost of executing simulations impedes running experiments with exhaustive parameter settings. Existing techniques of analyzing such a complex system typically focus on local sensitivity analysis, i.e. one parameter at a time, or a close "neighborhood" of particular parameter settings. However, such methods are not adequate to measure the uncertainty and sensitivity of parameters accurately because they overlook the global impacts of parameters on the system. In this article, we develop novel experimental design and analysis techniques to perform both global and local sensitivity analysis of large-scale ABMs. The proposed method can efficiently identify the most significant parameters and quantify their contributions to outcomes of the system. We demonstrate the proposed methodology for ENteric Immune SImulator (ENISI), a large-scale ABM environment, using a computational model of immune responses to Helicobacter pylori colonization of the gastric mucosa.

  13. Dynamic Simulation, Sensitivity and Uncertainty Analysis of a Demonstration Scale Lignocellulosic Enzymatic Hydrolysis Process

    Prunescu, Remus Mihail; Sin, Gürkan

    2014-01-01

    This study presents the uncertainty and sensitivity analysis of a lignocellulosic enzymatic hydrolysis model considering both model and feed parameters as sources of uncertainty. The dynamic model is parametrized for accommodating various types of biomass, and different enzymatic complexes...

  14. Sensitivity of subject-specific models to Hill muscle-tendon model parameters in simulations of gait.

    Carbone, V; van der Krogt, M M; Koopman, H F J M; Verdonschot, N

    2016-06-14

    Subject-specific musculoskeletal (MS) models of the lower extremity are essential for applications such as predicting the effects of orthopedic surgery. We performed an extensive sensitivity analysis to assess the effects of potential errors in Hill muscle-tendon (MT) model parameters for each of the 56 MT parts contained in a state-of-the-art MS model. We used two metrics, namely a Local Sensitivity Index (LSI) and an Overall Sensitivity Index (OSI), to distinguish the effect of the perturbation on the predicted force produced by the perturbed MT parts and by all the remaining MT parts, respectively, during a simulated gait cycle. Results indicated that sensitivity of the model depended on the specific role of each MT part during gait, and not merely on its size and length. Tendon slack length was the most sensitive parameter, followed by maximal isometric muscle force and optimal muscle fiber length, while nominal pennation angle showed very low sensitivity. The highest sensitivity values were found for the MT parts that act as prime movers of gait (Soleus: average OSI=5.27%, Rectus Femoris: average OSI=4.47%, Gastrocnemius: average OSI=3.77%, Vastus Lateralis: average OSI=1.36%, Biceps Femoris Caput Longum: average OSI=1.06%) and hip stabilizers (Gluteus Medius: average OSI=3.10%, Obturator Internus: average OSI=1.96%, Gluteus Minimus: average OSI=1.40%, Piriformis: average OSI=0.98%), followed by the Peroneal muscles (average OSI=2.20%) and Tibialis Anterior (average OSI=1.78%) some of which were not included in previous sensitivity studies. Finally, the proposed priority list provides quantitative information to indicate which MT parts and which MT parameters should be estimated most accurately to create detailed and reliable subject-specific MS models. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Sensitivity Analysis of Personal Exposure Assessment Using a Computer Simulated Person

    Brohus, Henrik; Jensen, H. K.

    2009-01-01

    The paper considers uncertainties related to personal exposure assessment using a computer simulated person. CFD is used to simulate a uniform flow field around a human being to determine the personal exposure to a contaminant source. For various vertical locations of a point contaminant source...... three additional factors are varied, namely the velocity, details of the computer simulated person, and the CFD model of the wind channel. The personal exposure is found to be highly dependent on the relative source location. Variation in the range of two orders of magnitude is found. The exposure...

  16. SIMULATIONS OF GAMMA-RAY BURST JETS IN A STRATIFIED EXTERNAL MEDIUM: DYNAMICS, AFTERGLOW LIGHT CURVES, JET BREAKS, AND RADIO CALORIMETRY

    De Colle, Fabio; Ramirez-Ruiz, Enrico [TASC, Department of Astronomy and Astrophysics, University of California, Santa Cruz, CA 95064 (United States); Granot, Jonathan [Racah Institute of Physics, The Hebrew University, Jerusalem 91904 (Israel); Lopez-Camara, Diego [Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, Ap. 70-543, 04510 D.F. (Mexico)

    2012-05-20

    The dynamics of gamma-ray burst (GRB) jets during the afterglow phase is most reliably and accurately modeled using hydrodynamic simulations. All published simulations so far, however, have considered only a uniform external medium, while a stratified external medium is expected around long duration GRB progenitors. Here, we present simulations of the dynamics of GRB jets and the resulting afterglow emission for both uniform and stratified external media with {rho}{sub ext}{proportional_to}r{sup -k} for k = 0, 1, 2. The simulations are performed in two dimensions using the special relativistic version of the Mezcal code. Common to all calculations is the initiation of the GRB jet as a conical wedge of half-opening angle {theta}{sub 0} = 0.2 whose radial profile is taken from the self-similar Blandford-McKee solution. The dynamics for stratified external media (k = 1, 2) are broadly similar to those derived for expansion into a uniform external medium (k = 0). The jet half-opening angle is observed to start increasing logarithmically with time (or radius) once the Lorentz factor {Gamma} drops below {theta}{sup -1}{sub 0}. For larger k values, however, the lateral expansion is faster at early times (when {Gamma} > {theta}{sup -1}{sub 0}) and slower at late times with the jet expansion becoming Newtonian and slowly approaching spherical symmetry over progressively longer timescales. We find that, contrary to analytic expectations, there is a reasonably sharp jet break in the light curve for k = 2 (a wind-like external medium), although the shape of the break is affected more by the viewing angle (for {theta}{sub obs} {<=} {theta}{sub 0}) than by the slope of the external density profile (for 0 {<=} k {<=} 2). Steeper density profiles (i.e., increasing k values) are found to produce more gradual jet breaks while larger viewing angles cause smoother and later appearing jet breaks. The counterjet becomes visible as it becomes sub-relativistic, and for k = 0 this results

  17. A third generation tomography system with fifteen detectors and a gamma-ray source in fan beam geometry simulated by Monte Carlo Method

    Velo, A.F.; Alvarez, A.G.; Carvalho, D.V.S.; Fernandez, V.; Somessari, S.; Sprenger, F.F.; Hamada, M.M.; Mesquita, C.H., E-mail: chmesqui@usp.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    This paper describes the Monte Carlo simulation, using MCNP4C, of a multichannel third generation tomography system containing a two radioactive sources, {sup 192}Ir (316.5 - 468 KeV) and {sup 137}Cs (662 KeV), and a set of fifteen NaI(Tl) detectors, with dimensions of 1 inch diameter and 2 inches thick, in fan beam geometry, positioned diametrically opposite. Each detector moves 10 steps of 0,24 deg , totalizing 150 virtual detectors per projection, and then the system rotate 2 degrees. The Monte Carlo simulation was performed to evaluate the viability of this configuration. For this, a multiphase phantom containing polymethyl methacrylate (PMMA ((ρ ≅ 1.19 g/cm{sup 3})), iron (ρ ≅ 7.874 g/cm{sup 3}), aluminum (ρ ≅ 2.6989 g/cm{sup 3}) and air (ρ ≅ 1.20479E-03 g/cm{sup 3}) was simulated. The simulated number of histories was 1.1E+09 per projection and the tally used were the F8, which gives the pulse height of each detector. The data obtained by the simulation was used to reconstruct the simulated phantom using the statistical iterative Maximum Likelihood Estimation Method Technique (ML-EM) algorithm. Each detector provides a gamma spectrum of the sources, and a pulse height analyzer (PHA) of 10% on the 316.5 KeV and 662 KeV photopeaks was performed. This technique provides two reconstructed images of the simulated phantom. The reconstructed images provided high spatial resolution, and it is supposed that the temporal resolution (spending time for one complete revolution) is about 2.5 hours. (author)

  18. A third generation tomography system with fifteen detectors and a gamma-ray source in fan beam geometry simulated by Monte Carlo Method

    Velo, A.F.; Alvarez, A.G.; Carvalho, D.V.S.; Fernandez, V.; Somessari, S.; Sprenger, F.F.; Hamada, M.M.; Mesquita, C.H.

    2017-01-01

    This paper describes the Monte Carlo simulation, using MCNP4C, of a multichannel third generation tomography system containing a two radioactive sources, 192 Ir (316.5 - 468 KeV) and 137 Cs (662 KeV), and a set of fifteen NaI(Tl) detectors, with dimensions of 1 inch diameter and 2 inches thick, in fan beam geometry, positioned diametrically opposite. Each detector moves 10 steps of 0,24 deg , totalizing 150 virtual detectors per projection, and then the system rotate 2 degrees. The Monte Carlo simulation was performed to evaluate the viability of this configuration. For this, a multiphase phantom containing polymethyl methacrylate (PMMA ((ρ ≅ 1.19 g/cm 3 )), iron (ρ ≅ 7.874 g/cm 3 ), aluminum (ρ ≅ 2.6989 g/cm 3 ) and air (ρ ≅ 1.20479E-03 g/cm 3 ) was simulated. The simulated number of histories was 1.1E+09 per projection and the tally used were the F8, which gives the pulse height of each detector. The data obtained by the simulation was used to reconstruct the simulated phantom using the statistical iterative Maximum Likelihood Estimation Method Technique (ML-EM) algorithm. Each detector provides a gamma spectrum of the sources, and a pulse height analyzer (PHA) of 10% on the 316.5 KeV and 662 KeV photopeaks was performed. This technique provides two reconstructed images of the simulated phantom. The reconstructed images provided high spatial resolution, and it is supposed that the temporal resolution (spending time for one complete revolution) is about 2.5 hours. (author)

  19. Sensitivity Studies on the Influence of Aerosols on Cloud and Precipitation Development Using WRF Mesoscale Model Simulations

    Thompson, G.; Eidhammer, T.; Rasmussen, R.

    2011-12-01

    Using the WRF model in simulations of shallow and deep precipitating cloud systems, we investigated the sensitivity to aerosols initiating as cloud condensation and ice nuclei. A global climatological dataset of sulfates, sea salts, and dust was used as input for a control experiment. Sensitivity experiments with significantly more polluted conditions were conducted to analyze the resulting impacts to cloud and precipitation formation. Simulations were performed using the WRF model with explicit treatment of aerosols added to the Thompson et al (2008) bulk microphysics scheme. The modified scheme achieves droplet formation using pre-tabulated CCN activation tables provided by a parcel model. The ice nucleation is parameterized as a function of dust aerosols as well as homogeneous freezing of deliquesced aerosols. The basic processes of aerosol activation and removal by wet scavenging are considered, but aerosol characteristic size or hygroscopicity does not change due to evaporating droplets. In other words, aerosol processing was ignored. Unique aspects of this study include the usage of one to four kilometer grid spacings and the direct parameterization of ice nucleation from aerosols rather than typical temperature and/or supersaturation relationships alone. Initial results from simulations of a deep winter cloud system and its interaction with significant orography show contrasting sensitivities in regions of warm rain versus mixed liquid and ice conditions. The classical view of higher precipitation amounts in relatively clean maritime clouds with fewer but larger droplets is confirmed for regions dominated by the warm-rain process. However, due to complex interactions with the ice phase and snow riming, the simulations revealed the reverse situation in high terrain areas dominated by snow reaching the surface. Results of other cloud systems will be summarized at the conferen