WorldWideScience

Sample records for gamma radiation measurement

  1. Environmental Gamma Radiation Measurements in Baskil District

    International Nuclear Information System (INIS)

    Canbazoglu, C.

    2008-01-01

    In this study, we have determined environmental gamma radiation dose rate in Baskil district which has very high granite content in its geographical structure. Gamma radiation dose rate measurements were achieved by portable radiation monitoring equipment based on the energy range between 40 keV and 1.3 MeV. The measurements were performed on asphalt and soil surface level and also one meter above the ground surface. The gamma dose rate was also performed inside and outside of buildings over the district. The dose rates were found to be between 8.46μR/h and 34.66 μR/h. Indoor and outdoor effective dose rate of the gamma radiation exposure has been calculated to be 523μSv/y and 196μSv/y, respectively

  2. Quality control of gamma radiation measuring systems

    International Nuclear Information System (INIS)

    Surma, M.J.

    2002-01-01

    The problem of quality control and assurance of gamma radiation measuring systems has been described in detail. The factors deciding of high quality of radiometric measurements as well as statistical testing and calibration of measuring systems have been presented and discussed

  3. Environmental gamma radiation measurements in Bangladeshi houses

    International Nuclear Information System (INIS)

    Idrish Miah, M.

    2002-01-01

    The indoor gamma dose rate in air measured using TLDs in the Dhaka district is not wide ranging and follows a normal distribution with an arithmetic mean of 1.54±0.26 mGy.y -1 . The result has been compared with those found by other investigators for different locations of the world. Measurements were made on a monthly basis for a year period, and a sinusoidal variation of monthly indoor gamma radiation of the type: d = 160 + 65 cos p/6 (m -1 ), where d is the indoor dose rate (nGy.h -1 ) and m the month, was observed. This might be due to seasonally varied air exchange rates of the houses. The average annual effective dose and the collective dose equivalent for the residents were estimated to be 0.86 mSv and 172.20 man-Sv respectively based on the indoor gamma exposure. (author)

  4. Environmental gamma radiation measurements in Bangladeshi houses

    International Nuclear Information System (INIS)

    Miah, M.I.

    2004-01-01

    Indoor gamma dose rate in air measured using TLDs in the Dhaka district is not wide ranging and follows a normal distribution with an arithmetic mean of 1.54±0.26 mGy y -1 . The result has been compared with those found by other investigators for different locations of the world. Measurements were made on a monthly basis for a year period, and a sinusoidal variation of monthly indoor gamma radiation of the type: d=160+65 cos π/6 (m-1), where d is the indoor dose rate (nGy h -1 ) and m the month. This might be due to the seasonally varied air exchange rates of the houses. The average annual effective dose and the collective dose equivalent for the residents were estimated to be 0.86 mSv and 172.20 man-Sv, respectively, based on the indoor gamma exposure

  5. Environmental gamma radiation measurements in Bangladeshi houses

    Energy Technology Data Exchange (ETDEWEB)

    Miah, M.I. E-mail: idrish_physics@yahoo.com

    2004-06-01

    Indoor gamma dose rate in air measured using TLDs in the Dhaka district is not wide ranging and follows a normal distribution with an arithmetic mean of 1.54{+-}0.26 mGy y{sup -1}. The result has been compared with those found by other investigators for different locations of the world. Measurements were made on a monthly basis for a year period, and a sinusoidal variation of monthly indoor gamma radiation of the type: d=160+65 cos {pi}/6 (m-1), where d is the indoor dose rate (nGy h{sup -1}) and m the month. This might be due to the seasonally varied air exchange rates of the houses. The average annual effective dose and the collective dose equivalent for the residents were estimated to be 0.86 mSv and 172.20 man-Sv, respectively, based on the indoor gamma exposure.

  6. Measuring element for the detection and determination of radiation doses of gamma radiation and neutrons

    International Nuclear Information System (INIS)

    Jahn, W.; Piesch, E.

    1975-01-01

    A measuring element detects and proves both gamma and neutron radiation. The element includes a photoluminescent material which stores gamma radiation and particles of arsenic and phosphorus embedded in the photoluminescent material for detecting neutron radiation. (U.S.)

  7. Mathematical simulation of gamma-radiation angle distribution measurements

    International Nuclear Information System (INIS)

    Batij, V.G.; Batij, E.V.; Egorov, V.V.; Fedorchenko, D.V.; Kochnev, N.A.

    2008-01-01

    We developed mathematical model of the facility for gamma-radiation angle distribution measurement and calculated response functions for gamma-radiation intensities. We developed special software for experimental data processing, the 'Shelter' object radiation spectra unfolding and Sphere detector (ShD) angle resolution estimation. Neuronet method using for detection of the radiation directions is given. We developed software based on the neuronet algorithm, that allows obtaining reliable distribution of gamma-sources that make impact on the facility detectors at the measurement point. 10 refs.; 15 figs.; 4 tab

  8. Measurement of background gamma radiation in the northern Marshall Islands.

    Science.gov (United States)

    Bordner, Autumn S; Crosswell, Danielle A; Katz, Ainsley O; Shah, Jill T; Zhang, Catherine R; Nikolic-Hughes, Ivana; Hughes, Emlyn W; Ruderman, Malvin A

    2016-06-21

    We report measurements of background gamma radiation levels on six islands in the northern Marshall Islands (Enewetak, Medren, and Runit onEnewetak Atoll; Bikini and Nam on Bikini Atoll; and Rongelap on Rongelap Atoll). Measurable excess radiation could be expected from the decay of (137)Cs produced by the US nuclear testing program there from 1946 to 1958. These recordings are of relevance to safety of human habitation and resettlement. We find low levels of gamma radiation for the settled island of Enewetak [mean = 7.6 millirem/year (mrem/y) = 0.076 millisievert/year (mSv/y)], larger levels of gamma radiation for the island of Rongelap (mean = 19.8 mrem/y = 0.198 mSv/y), and relatively high gamma radiation on the island of Bikini (mean = 184 mrem/y = 1.84 mSv/y). Distributions of gamma radiation levels are provided, and hot spots are discussed. We provide interpolated maps for four islands (Enewetak, Medren, Bikini, and Rongelap), and make comparisons to control measurements performed on the island of Majuro in the southern Marshall Islands, measurements made in Central Park in New York City, and the standard agreed upon by the United States and the Republic of the Marshall Islands (RMI) governments (100 mrem/y = 1 mSv/y). External gamma radiation levels on Bikini Island significantly exceed this standard (P = <0.01), and external gamma radiation levels on the other islands are below the standard. To determine conclusively whether these islands are safe for habitation, radiation exposure through additional pathways such as food ingestion must be considered.

  9. Measuring stations for gamma radiation - measured results 1982

    International Nuclear Information System (INIS)

    Kjelle, P.E.

    1983-01-01

    Gamma radiation is recorded continuously at 25 stations in Sweden. The evaluation of the data from five of the stations is made in a most accurate way, and the results are presented in this report. (G.B.)

  10. Measurement of gamma radiation doses in nuclear power plant environment

    International Nuclear Information System (INIS)

    Bochvar, I.A.; Keirim-Markus, I.B.; Sergeeva, N.A.

    1976-01-01

    Considered are the problems of measuring gamma radiation dose values and the dose distribution in the nuclear power plant area with the aim of estimating the extent of their effect on the population. Presented are the dosimeters applied, their distribution throughout the controlled area, time of measurement. The distribution of gamma radiation doses over the controlled area and the dose alteration with the increase of the distance from the release source are shown. The results of measurements are investigated. The conclusion is made that operating nuclear power plants do not cause any increase in the gamma radiation dose over the area. Recommendations for clarifying the techniques for using dose-meters and decreasing measurement errors are given [ru

  11. Studying and measuring the gamma radiation doses in Homs city

    International Nuclear Information System (INIS)

    Sofaan, A. H.

    2001-01-01

    The gamma radiation dose was measured in Homs city by using many portable dosimeters (electronic dosimeter and Geiger-Muller). The measurements were carried out in the indoor and outdoor buildings, for different time period, through one year (1999-2000). High purity germanium detector with low back ground radiation (HpGe) was used to determine radiation element contained in some building and the surrounding soil. The statistical analysis laws were applied to make sure that the measured dose distribution around average value is normal distribution. The measurement indicates that the gamma indoor dose varies from 312μSv/y to 511μSv/y, with the average annual dose of 385μSv/y. However the gamma outdoor dose rate varies from 307μSv/y to 366μSv/y with an average annual dose 385μSv/y. The annual outdoor gamma radiation dose is about %16 lower than the outdoor dose in Homs City. These measurements have indicated that environmental gamma doses in Homs City are relatively low. This is because that most of the soils and rocks in the area are limestone. (author)

  12. Measurement and Calculation of Gamma Radiation from HWZPR Reactor

    International Nuclear Information System (INIS)

    Jalali, Majid

    2006-01-01

    HWZPR is a research reactor with natural uranium fuel, D 2 O moderator and graphite reflector with maximum power of 100 W. It is a suitable means for theoretical research and heavy water reactor experiments. Neutrons from the core participate in different nuclear reactions by interactions with fuel, moderator, graphite and the concrete around the reactor. The results of these interactions are the production of prompt gammas in the environment. Useful information is gained by the reactor gamma spectrum measurement from point of view of relative quantity and energy distribution of direct and scattered radiations. Reactor gamma ray spectrum has been gathered in different places around the reactor by HPGe detector. In analysis of these spectra, 1 H(n,γ) 2 H, 16 O(n,n'γ) 16 O, 2 H(n,γ) 3 H and 238 U(n,γ) 239 U reactions occurring in reactor moderator and fuel, are important. The measured spectrum has been primarily estimated by the MCNP code. There is agreement between the code and the experiments in some points. The scattered gamma rays from 27 Al (n,γ) 28 Al reaction in the reactor tank, are the most among the gammas scattered in the reactor environment. Also the dose calculations by MCNP code show that 72% of gamma dose belongs to the energy range 3-11 MeV from reactor gamma spectrum and the danger of exposure from the reactor high-energy photons is serious. (author)

  13. Density measurement using gamma radiation - theory and application

    International Nuclear Information System (INIS)

    Springer, E.K.

    1979-01-01

    There are still widespread uncertainties about the use and safety of gamma radiation in industries. This paper describes, by the example of radiometric density measurement, the theory of gamma radiation. The differences and advantages of both types of detectors, the ionization chamber and the scintillation counter, are discussed. The degree of accuracy which can be expected from the radiometric density meter will be defined, and the inter-relationship: source strength - measuring range - measuring length(normally the pipe diameter) in relation to the measuring accuracy required will be explained in detail. The use of radioactive material requires the permission of the Atomic Energy Board. The formalities involved to receive a user's licence and the implementations of safety standards set by the local authorities are discussed in depth [af

  14. Mobile equipment for measurement of gamma radiation

    International Nuclear Information System (INIS)

    2009-01-01

    NRPA has several systems to perform mobile measurements. One of the systems consists of detectors mounted on the roof of a car. Mobile systems can be used to map the radioactive contamination of large areas in a short time, to the reference measurements and to search for sources astray. The systems can be mounted on the vehicle or used in a helicopter or airplane. (AG)

  15. Control device intended for a gamma radiation measuring instrument

    International Nuclear Information System (INIS)

    1976-01-01

    This invention concerns a monitoring device for a gamma radiation measuring instrument or radiation meter, in which the radiation to be measured brings about, inter alia, the ionisation of a gas and the generation of current pulses. The dial of this meter is generally calibrated in roentgens per hour, i.e. in radiation rate units. This instrument of very simple design is remarkable for its operating reliability. Preferably placed at the inlet to a radioactive area, it enables every user of a ratemeter to check, over the entire measuring range of this instrument, its proper operation prior to entering the area. To this effect, the monitoring device in question has a thick wall lead castle, having an internal cavity in which is mounted a radioactive source delivering a gamma radiation with given constant characteristics, through a measurement window closed by a calibrated plug. Lead doors articulated on the castle can be superimposed on this window to bring about a given attenuation of the radiation coming from the source and delivered to the exterior of the castle [fr

  16. The use of gamma radiation in fluid flow measurements

    International Nuclear Information System (INIS)

    Tjugum, S.A.; Johansen, G.A.

    2000-01-01

    The use of gamma radiation in densitometry measurements is a well known principle. These measurements are often used in the oil industry where there is a need for finding the gas fraction of an oil/water/gas flow. The traditional gamma densitometer has a simple construction, where the measured parameter is the attenuation of a single gamma beam. High reliability, robustness and the clamp-on possibility are advantages that this type of instruments offer. More information can be found by studying how radiation is scattered and absorbed by matter. This information is needed in new multiphase flow meters. Problems to be solved in these instruments are how to find volume fractions of more than two components, how to handle different flow regimes in non-homogeneous flow, and how to do measurements independent of the salinity of the water. The new technology involves multi-energy, multi-mode and multi-sensor systems. At the University of Bergen the focus has been on how to do flow regime and salinity independent measurements by using multi-sensor and multi-mode systems. This paper gives an overview of the different techniques, and presents the latest results within this field of research at the University of Bergen. (author)

  17. Spectral measurements of gamma radiation streaming through ducts

    International Nuclear Information System (INIS)

    Meenakshisundaram, P.K.; Bhatnagar, V.M.; Raghunath, V.M.; Gopinath, D.V.

    1979-01-01

    The paper presents the spectral measurements of gamma radiation streaming through multi-legged rectangular concrete ducts for cesium-137 and cobald-60 sources. Effect of lead lining the inner surface of the duct on the streaming radiation spectrum and optimization of liner thickness for minimum streaming radiation dose have been studied. For three-legged ducts, a comparative analysis of lead lining the entire duct as against lining any one or both the corners of the duct is reported. It is seen that lead lining any one of the corners would reduce the streaming radiation dose by a factor of 5 to 12. Lining both the corners which is nearly as effective as lining the entire duct reduces the dose by a factor of 16 to 60 depending on the soruce energy and duct dimensions. (orig.)

  18. Preliminary measurements of gamma radiation in Chilean Antarctic Stations

    Energy Technology Data Exchange (ETDEWEB)

    Stuardo B, E. (Comision Chilena de Energia Nuclear, Santiago. Dept. de Aplicaciones Nucleares)

    1983-11-01

    Natural and artificial gamma radiation, 1 m above the soil, is being investigated in 4 Chilean Antartic Stations. The measurements are performed with different types of TLD detectors. Preliminary results in the Tte. Marsh Station are reported and discussed. An average exposition of 3,5 ..mu..R/h was found during a 108 days period. This exposition corresponds to an annual dose of about 40 mrad, 8% of the annual dose limit for individual of the public. The presence of low energy artificial radioisotopes was not found.

  19. Preliminary measurements of gamma radiation in Chilean Antarctic Stations

    International Nuclear Information System (INIS)

    Stuardo B, E.

    1983-01-01

    Natural and artificial gamma radiation, 1 m above the soil, is being investigated in 4 Chilean Antartic Stations. The measurements are performed with different types of TLD detectors. Preliminary results in the Tte. Marsh Station are reported and discussed. An average exposition of 3,5 μR/h was found during a 108 days period. This exposition corresponds to an annual dose of about 40 mrad, 8% of the annual dose limit for individual of the public. The presence of low energy artificial radioisotopes was not found. (Author)

  20. Measurement of the radiative decay width {gamma}[{lambda}(1520)->{lambda}{gamma}] with the SPHINX spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Antipov, Yu.M. [Institute for High Energy Physics, Protvino (Russian Federation); Artamonov, A.V. [Institute for High Energy Physics, Protvino (Russian Federation); Batarin, V.A. [Institute for High Energy Physics, Protvino (Russian Federation); Vavilov, D.V. [Institute for High Energy Physics, Protvino (Russian Federation); Victorov, V.A. [Institute for High Energy Physics, Protvino (Russian Federation); Eroshin, O.V. [Institute for High Energy Physics, Protvino (Russian Federation); Golovkin, S.V. [Institute for High Energy Physics, Protvino (Russian Federation); Gorin, Yu.P. [Institute for High Energy Physics, Protvino (Russian Federation); Kolganov, V.Z. [Institute of Theoretical and Experimental Physics, Moscow (Russian Federation); Kozhevnikov, A.P. [Institute for High Energy Physics, Protvino (Russian Federation); Konstantinov, A.S. [Institute for High Energy Physics, Protvino (Russian Federation); Kubarovsky, V.P. [Institute for High Energy Physics, Protvino (Russian Federation); Kurshetsov, V.F. [Institute for High Energy Physics, Protvino (Russian Federation); Landsberg, L.G. [Institute for High Energy Physics, Protvino (Russian Federation)]. E-mail: lgl@mx.ihep.su; Leontiev, V.M. [Institute for High Energy Physics, Protvino (Russian Federation); Lomkatsi, G.S. [Institute of Theoretical and Experimental Physics, Moscow (Russian Federation); Molchanov, V.V. [Institute for High Energy Physics, Protvino (Russian Federation)]. E-mail: molchanov@mx.ihep.su; Mukhin, V.A. [Institute for High Energy Physics, Protvino (Russian Federation); Nilov, A.F. [Institute of Theoretical and Experimental Physics, Moscow (Russian Federation); Patalakha, D.I. [Institute for High Energy Physics, Protvino (Russian Federation); Petrenko, S.V. [Institute for High Energy Physics, Protvino (Russian Federation); Smolyankin, V.T. [Institute of Theoretical and Experimental Physics, Moscow (Russian Federation)

    2004-12-16

    The radiative decay {lambda}(1520)->{lambda}{gamma} was measured directly in the study of the exclusive diffractive-like reaction p+N->{lambda}(1520)K{sup +}+N, {lambda}(1520)->{lambda}{gamma} with the SPHINX spectrometer. The values of the branching and partial width of this radiative decay were obtained: BR[{lambda}(1520)->{lambda}{gamma}]=(1.02+/-0.21(stat)+/-0.15(syst))x10{sup -2} and {gamma}[{lambda}(1520)->{lambda}{gamma}]=159+/-33(stat)+/-26(syst)-bar keV.

  1. Environmental gamma radiation measurement in District Swat (Pakistan))

    International Nuclear Information System (INIS)

    Jabbar, T.; Khan, K.; Akhter, P.; Jabbar, A.; Subhani, M.S.

    2008-01-01

    External exposure to environmental gamma ray sources is an important component of exposure to the public. A survey was carried out to determine activity concentration levels and associated doses from 226 Ra, 232 Th, 40 K and 137 Cs by means of high-resolution gamma ray spectrometry in the Swat district, famous for tourism. The mean concentrations for 226 Ra, 232 Th and 40 K were found to be 50.4 ± 0.7, 34.8 ± 0.7 and 434.5 ± 7.4 Bq kg -1 , respectively, in soil samples, which are slightly more than the world average values. However, 137 Cs was only found in the soil sample of Barikot with an activity concentration of 34 ± 1.2 Bq kg -1 . Only 40 K was determined in vegetation samples with an average activity of 172.2 ± 1.7 Bq kg -1 , whereas in water samples, all radionuclides were found below lower limits of detection. The radium equivalent activity in all soil samples is lower than the limit set in the Organisation for Economic Cooperation and Development report (370 Bq kg -1 ). The value of the external exposure dose has been determined from the content of these radionuclides in soil. The average terrestrial gamma air absorbed dose rate was observed to be 62.4 nGy h -1 , which yields an annual effective dose of 0.08 mSv. The average value of the annual effective dose lies close to the global range of outdoor radiation exposure given in United Nations Scientific Committee on the Effects of Atomic Radiation. However, the main component of the radiation dose to the population residing in the study area arises from cosmic ray due to high altitude. (authors)

  2. Measurement of background gamma radiation in the northern Marshall Islands

    OpenAIRE

    Bordner, Autumn S.; Crosswell, Danielle A.; Katz, Ainsley O.; Shah, Jill T.; Zhang, Catherine R.; Nikolic-Hughes, Ivana; Hughes, Emlyn W.; Ruderman, Malvin A.

    2016-01-01

    Sixty-seven nuclear tests were conducted on two atolls in the northern Marshall Islands between 1946 and 1958. These tests produced radioactive fallout, which even today gives rise to radiation measurable above naturally occurring background levels. Rather than obtain new data, recent estimates of contamination levels in the northern Marshall Islands use measurements made decades ago to calculate present radiation levels. In contrast, we report on timely measurements on three different atolls...

  3. Measurement of Background Gamma Radiation Levels at Two ...

    African Journals Online (AJOL)

    MICHAEL

    ABSTRACT: An in-situ measurement of the background radiation level was carried out at the vicinity of three ... Soil contains small quantities of radioactive elements along with their progeny. .... assessment for soil samples from Kestanbol.

  4. Measurements of Small Exposures of Gamma Radiation with CaSO{sub 4}:Mn Radiothermoluminescence

    Energy Technology Data Exchange (ETDEWEB)

    Bjaerngard, Bengt

    1963-08-15

    A system for measurements of small exposures of gamma radiation using CaSO{sub 4}:Mn thermoluminescence has been developed. The construction and performance of a read-out apparatus is described as well as the construction and characteristics of a simple dosimeter. The reproducibility of the method at various exposures is estimated. 20 {mu}R of 1 MeV gamma radiation can be measured with a reproducibility within {+-} 50 % (standard deviation)

  5. Measurement of Gamma Radiation in an Automobile Mechanic ...

    African Journals Online (AJOL)

    Environmental radiation measurement was carried out in an automobile mechanic village, Apo, Abuja, Nigeria. An in-situ measurement approach was adopted using RDS-200 Universal Survey Meter and a handheld Global Positioning System (Garmin GPS 76S) equipment. It was observed that the dose equivalent varied ...

  6. Integral alpha and gamma radiation measurements in dwelling houses

    International Nuclear Information System (INIS)

    Paripas, B.; Takacs, S.; Somogyi, G.; Nikl, I.

    1984-01-01

    A solid state nuclear track detector method is applied to determine radon and total alpha-exposures (time integral of activity concentrations). The mathematical description of the method of measurement by a passive device equipped with two plastic sheets is presented. Measurements have been carried out in 88 houses over a five-month period and in 20 houses every season for a whole year. Simultaneously with the seasonal measurements of alpha-exposures, the gamma doses were also determined by means of TL dosemeters. The mean exposures due to thoron and its progeny have been estimated by statistical methods. A possible connection between the measured quantities and the lung cancer rates in two settlements were examined. (Author)

  7. Measurement of gamma radiation doses at the RA reactor by thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Prokic, M.

    1974-01-01

    This paper presents the procedures and gamma radiation doses measured at the exit from the horizontal experimental channel HK-5, vertical experimental channel VK-5 and in the thermal column of the RA reactor in Vinca. Measurement of gamma radiation dose in the mixed intense gamma and neutron radiation field was done by two types of thermoluminescent dosemeters, LiF (TLD-700) and CaF 2 (TLD-08). Gamma dose in the VK-5 was measured in the air and on the bottle filled with tissue-equivalent solution. Increase of the dose on the surface of the bottle was 2.3 compared to the gamma dose value in the air. Correction for the influence of neutrons having different energies was done by using the known sensitivity values of both TL dosemeter types for thermal, intermediate and fast neutrons. Results showed that the TLD-700 dosemeter contains 5 time more Li-6 isotopes (0.035%) than the declared value causing increased neutron sensitivity of this dosemeter. This paper includes numerical sensitivity data for neutrons of different energies for both types of TL dosemeters. Neutron sensitivity values for TLD-700 are related to LiF with 0.035% of Li-6 isotope. Result of measurement have also shown that the CaF 2 :Mn (TLD-08) thermoluminescent dosemeter is more suitable for gamma radiation dose measurements in mixed n-gamma fields with intensive neutron fluxes due to lower neutron sensitivity compared to TLD-700 [sr

  8. Measurement of Gamma Radiation in an Automobile Mechanic ...

    African Journals Online (AJOL)

    imeh james

    Nuclear Technology Centre, Nigeria Atomic Energy Commission, ... An in-situ measurement approach was adopted using RDS-200 Universal Survey Meter and a handheld ... the people living and working within the area are safe and are not exposed to high doses of radiation as a result .... battery works, panel beating e.t.c..

  9. The measurement of alpha, beta and gamma radiations

    International Nuclear Information System (INIS)

    Burns, P.A.

    1982-01-01

    Detection methods for nuclear radiations are based on the processes of excitation and ionization of atoms in the detection medium by the passage of a charged particle. Detectors are usually of two types, those which produce a charge pulse following ionization of the medium and those which produce a burst of light photons which are then detected by a photomultiplier tube. By processing the electronic signals produced in suitable ways either the count rate of the source, the activity, or the dose equivalent to a person may be determined. In order to make these determinations it is necessary to understand the type of nuclear transformation of the radionuclide in question, the type and energy of the radiation being emitted and the processes involved when these radiations pass through the medium of the detector. Suitable choice of detectors and extrapolation from measured data to the quantity which is to be determined can then be made

  10. Snowpack snow water equivalent measurement using the attenuation of cosmic gamma radiation

    International Nuclear Information System (INIS)

    Osterhuber, R.; Condreva, K.

    1998-01-01

    Incoming, background cosmic radiation constantly fluxes through the earth's atmosphere. The high energy gamma portion of this radiation penetrates many terrestrial objects, including the winter snowpack. The attenuation of this radiation is exponentially related to the mass of the medium through which it penetrates. For the past three winters, a device measuring cosmic gamma radiation--and its attenuation through snow--has been installed at the Central Sierra Snow Laboratory, near Donner Pass, California. This gamma sensor, measuring energy levels between 5 and 15 MeV, has proved to be an accurate, reliable, non-invasive, non-mechanical instrument with which to measure the total snow water equivalent of a snowpack. This paper analyzes three winters' worth of data and discusses the physics and practical application of the sensor for the collection of snow water equivalent data from a remote location

  11. gamma. radiation of ionium

    Energy Technology Data Exchange (ETDEWEB)

    Curie, I

    1948-12-08

    Following the work of Ward (Proc Cambridge Phil Soc 35 322(1939)), the ..gamma..-radiation of ionium (from an IoTh preparation) was studied with the aid of Ta and W screens, and an aluminum counter. The screen measurements confirmed Ward's findings of two radiations, of 68 keV and of about 200 keV. The number of quanta per second of each radiation was determined with the counter, which has been calibrated on certain L lines of radium. The global quanta number of L lines of ionium was also determined. The results were as follows: 0.7 quanta ..gamma.. of 68 keV for 100 ..cap alpha..-particles; 0.2 quanta ..gamma.. of 200 keV for 100 ..cap alpha..-particles; 10 quanta L for 100 ..cap alpha..-particles. These data, which show an important internal conversion, agree with the findings of Teillac (Compt Rend 227 1227 (1948)), who investigated the ..beta..-radiation of ionium. It is the radiation 68 keV which is highly converted. On the other hand, these results do no agree with the data on the fine structure of ionium found by Rosenblum, Valadares, and Vial (Compt Rend 227 1088(1948)).

  12. Measurement of natural gamma radiation in building materials from Thellar of Tiruvannamalai Dist, Tamilnadu, India by gamma ray spectrometry

    International Nuclear Information System (INIS)

    Raghu, Y.; Ravisankar, R.; Chandrasekararn, A.; Vijayagopal, P.; Venkatraman, B.

    2016-01-01

    The knowledge of natural radioactivity in building materials is an important aspect of or determining the amount of public exposure because people spend most of their time (about 80%) indoors. Further, the knowledge of this radioactivity is useful in setting the standards and national guidelines in regard to the international recommendations and in assessing the associated radiation hazard. In the present work, the concentrations of natural radionuclides were measured in four types of building materials from Thellar of Tiruvannamalai district, Tamilnadu, India using gamma-ray spectrometry and associated radiological hazards are calculated

  13. The primary exposure standard for Co-60 gamma radiation: characteristics and measurements procedures

    International Nuclear Information System (INIS)

    Laitano, R.F.; Toni, M.P.

    1983-01-01

    A description is given of a cavity ionization chamber used, as a primary exposure standard, at the Laboratorio di Metrologia delle Radiazioni Ionizzanti of the ENEA in Italy. The primary standard is designed to make absolute measurements of exposure due to the Co-60 gamma radiation. The procedures for the realizationof the exposure unit are also described. Finally results of some international comparisons are reported

  14. Measurement of environmental gamma radiation by means of a large volume ionization chamber

    International Nuclear Information System (INIS)

    Gauthier, Daniel; Caput, Claude.

    1980-02-01

    A device for the measurement of the intensity of environmental gamma radiation has been realized and set up inside a vehicle especially fitted to that purpose. Because of its characteristics of sensitivity and time of response light and very local anomalies due for instance to foreign materials or punctual geological bassets can be detected and maps of dose rates at a regional scale can be drawn up. Such maps drawn before and after the operation of nuclear plants make it possible to assess their impact on environmental radiation levels [fr

  15. Levels of naturally occurring gamma radiation measured in British homes and their prediction in particular residences

    Energy Technology Data Exchange (ETDEWEB)

    Kendall, G.M. [University of Oxford, Cancer Epidemiology Unit, Oxford (United Kingdom); Wakeford, R. [University of Manchester, Centre for Occupational and Environmental Health, Institute of Population Health, Manchester (United Kingdom); Athanson, M. [University of Oxford, Bodleian Library, Oxford (United Kingdom); Vincent, T.J. [University of Oxford, Childhood Cancer Research Group, Oxford (United Kingdom); Carter, E.J. [University of Worcester, Earth Heritage Trust, Geological Records Centre, Henwick Grove, Worcester (United Kingdom); McColl, N.P. [Public Health England, Centre for Radiation, Chemical and Environmental Hazards, Chilton, Didcot, Oxon (United Kingdom); Little, M.P. [National Cancer Institute, DHHS, NIH, Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, Bethesda, MD (United States)

    2016-03-15

    Gamma radiation from natural sources (including directly ionising cosmic rays) is an important component of background radiation. In the present paper, indoor measurements of naturally occurring gamma rays that were undertaken as part of the UK Childhood Cancer Study are summarised, and it is shown that these are broadly compatible with an earlier UK National Survey. The distribution of indoor gamma-ray dose rates in Great Britain is approximately normal with mean 96 nGy/h and standard deviation 23 nGy/h. Directly ionising cosmic rays contribute about one-third of the total. The expanded dataset allows a more detailed description than previously of indoor gamma-ray exposures and in particular their geographical variation. Various strategies for predicting indoor natural background gamma-ray dose rates were explored. In the first of these, a geostatistical model was fitted, which assumes an underlying geologically determined spatial variation, superimposed on which is a Gaussian stochastic process with Matern correlation structure that models the observed tendency of dose rates in neighbouring houses to correlate. In the second approach, a number of dose-rate interpolation measures were first derived, based on averages over geologically or administratively defined areas or using distance-weighted averages of measurements at nearest-neighbour points. Linear regression was then used to derive an optimal linear combination of these interpolation measures. The predictive performances of the two models were compared via cross-validation, using a randomly selected 70 % of the data to fit the models and the remaining 30 % to test them. The mean square error (MSE) of the linear-regression model was lower than that of the Gaussian-Matern model (MSE 378 and 411, respectively). The predictive performance of the two candidate models was also evaluated via simulation; the OLS model performs significantly better than the Gaussian-Matern model. (orig.)

  16. Levels of naturally occurring gamma radiation measured in British homes and their prediction in particular residences

    International Nuclear Information System (INIS)

    Kendall, G.M.; Wakeford, R.; Athanson, M.; Vincent, T.J.; Carter, E.J.; McColl, N.P.; Little, M.P.

    2016-01-01

    Gamma radiation from natural sources (including directly ionising cosmic rays) is an important component of background radiation. In the present paper, indoor measurements of naturally occurring gamma rays that were undertaken as part of the UK Childhood Cancer Study are summarised, and it is shown that these are broadly compatible with an earlier UK National Survey. The distribution of indoor gamma-ray dose rates in Great Britain is approximately normal with mean 96 nGy/h and standard deviation 23 nGy/h. Directly ionising cosmic rays contribute about one-third of the total. The expanded dataset allows a more detailed description than previously of indoor gamma-ray exposures and in particular their geographical variation. Various strategies for predicting indoor natural background gamma-ray dose rates were explored. In the first of these, a geostatistical model was fitted, which assumes an underlying geologically determined spatial variation, superimposed on which is a Gaussian stochastic process with Matern correlation structure that models the observed tendency of dose rates in neighbouring houses to correlate. In the second approach, a number of dose-rate interpolation measures were first derived, based on averages over geologically or administratively defined areas or using distance-weighted averages of measurements at nearest-neighbour points. Linear regression was then used to derive an optimal linear combination of these interpolation measures. The predictive performances of the two models were compared via cross-validation, using a randomly selected 70 % of the data to fit the models and the remaining 30 % to test them. The mean square error (MSE) of the linear-regression model was lower than that of the Gaussian-Matern model (MSE 378 and 411, respectively). The predictive performance of the two candidate models was also evaluated via simulation; the OLS model performs significantly better than the Gaussian-Matern model. (orig.)

  17. Rules concerning radiation protection measures to be taken in the event of accidents with gamma radiography

    International Nuclear Information System (INIS)

    1981-01-01

    These rules issued by the State Institute of Radiation Hygiene (SIS) set out the obligations of licensees and radiographers regarding radiation protection and accident prevention in relation to gamma radiography. (NEA)

  18. Measurement of gamma natural background radiation at Chamaraja Nagar, Karnataka state, India

    International Nuclear Information System (INIS)

    Nagaraju, K.M.; Chandrashekara, M.S.; Paramesh, L.

    2012-01-01

    The radioactive elements and their radiation are ubiquitous in the environment. The Influence of radiation on living organisms is imminent and very important to study. The ocean, the mountains, the air, and our food all expose us to small amounts of natural background radiation. Cosmic rays from outer space are another large contributor of natural background radiation. Much of the earth's natural background radiation is in the form of gamma radiation, a part of which comes from outer space. Some part of cosmic ray is filtered out by the presence of earth's atmosphere, so there are natural controls for the amount of radiation that people receive. The amount of radiation received by an individual depends on altitude, latitude type of building and the building construction materials. In the present study, measurements of natural background radiation were made in the temples, schools, dwellings, and hill stations in Chamaraja Nagar area, Karnataka state, India by using environmental dosimeter technique. The results show that, absorbed dose rate of background radiations at inside schools varies from 93.96 to 120.93 nGyh -1 with a standard deviation of 10.62 nGyh -1 and outside schools it varies from 60.9 to 113.1 nGyh -1 with a standard deviation of 15.1 nGyh -1 . In temples, the absorbed dose rate varies from 104.4 to 244.91 nGyh - 1 with a standard deviation of 48.34 nGyh -1 and outside the temples it varies from 87.9 to 176.61 nGyh -1 with a standard deviation of 30.896 nGyh -1 . The absorbed dose rate of background radiations at dwellings in indoor varies from 94.0 to 139.2 nGyh -1 with a standard deviation of 16.6 nGyh -1 and in outdoor it varies from 60.9 to 118.32 nGyh -1 with a standard deviation of 19.41 nGyh -1 . The measurements were also carried out in dwellings on hill stations in Chamaraja Nagar district. Indoor gamma dose rate varies from 103.53 to 236.64 nGyh -1 with a standard deviation of 59.8 nGyh -1 and outdoor gamma dose rate varies from 78.3 to 119

  19. Density measurement by means of once scattered gamma radiation the ETG probe, principles and equipment

    International Nuclear Information System (INIS)

    Joergensen, J.L.; Oelgaard, P.L.; Berg, F.

    1987-01-01

    The Department of Electrophysics, the Technical University of Denmark, and the Danish National Road Laboratory have together developed a new patent claimed device for measurements of the in situ density of materials. This report describes the principles of the system and some experimental results. The system is based on the once scattered gamma radiation. In a totally non-destructive and fast way it is possible to measure the density of up to 25 cm thick layers. Furthermore, an estimate of the density variation through the layer may be obtained. Thus the gauge represents a new generation of equipment for e.g. compaction control of road constructions. (author)

  20. Environmental gamma-ray dose measurements with thermoluminescence dosemeters (TLD) and environmental radiation characteristics

    International Nuclear Information System (INIS)

    Kanematsu, Seiko

    1999-01-01

    It is important to evaluate environmental gamma-ray exposure both at work and home in order to assess people's collective dosages. Environmental gamma radiation was measured for air-absorbed dose with a thermoluminescence dosemeter at various points in the workplace and Ningyotoge, and workplace radiation characteristics were analyzed. From the results, the public dose due to gamma rays generated artificially was assessed to be sufficiently lower than the annual limit. For indoor environments of the workplace, the maximum dosage rate among measured values was 97 nGy/h and the minimum value was 70 nGy/h, the average over one year was 83 nGy/h. The average annual outdoor dosage for a year was 82 nGy/ h. In Ningyotoge, the maximum was 103 nGy/h, minimum 60 nGy/h, and average 88 nGy/h. These values depend on the nature of the soil and weather factors, showing higher values in the summer than in the winter in the workplace. There was no significant difference in the dosage rate in houses and the workplace. (author)

  1. A new programmable zone dosimeter for operational monitoring and measurement of external gamma radiation

    International Nuclear Information System (INIS)

    Toledo Acosta, Rene; Arteche Diaz, Raul; Mesa Perez, Guillermo; Fernandez Llanez, Sandra; Tamayo Garcia, Jose Antonio; Alonso Villanueva, Gilberto

    2010-01-01

    The detection and the measurement of the nuclear radiations have turn into an important item in the nuclear detectors application and specifically the Geiger Muller ones. Coming from theirs high detection sensibility, robust construction and relative simplicity of the associated circuit, the Geiger Tubes are still one of the most widely used detectors in all the application areas regarding physics and nuclear investigations A new design instrument is presented to be measures the ambient dose of external (gamma) radiation since 10 mSv/h. It consists of three elements: Geiger-Muller detector, the electronic board for the acquisition and control and the application software. The instrument communicates trough a USB interface to the Personal Computer only for adjust calibration parameters. The software was developed in the C programming language using PICC4, 08 compilers. (author)

  2. Ionizing radiation population doses at Sao Paulo city, Brazil: open-pit gamma dose measurement

    International Nuclear Information System (INIS)

    Oliveira, Raimundo Enoch Rodrigues

    2001-01-01

    The effects of ionizing radiation to the human beings are well known for high and intermediate doses. As far as low level) radiation doses are concerned, there is no consensus. In order to get a better understanding of such effects it is necessary to assess the low doses with better accuracy. In this work, it was made an estimate of the annual ambient dose equivalent (H * (10)) to which the people are exposed in the city of Sao Paulo. Until now there are no data about it available in the literature. For the purpose of this evaluation, a map with various routes covering the largest and more representative area of the city was designed. The choice of points for data collection was made taking into account mainly the occupancy of the region. A portable gamma spectrometry system was used. It furnishes the rate of H * (10) and the measured gamma spectrum (in the range from 50 to 1670 keV) in the place of interest. The measurements were performed in a short time interval, since the gamma radiation arrives from a great extent of soil. Each measurement was done 1 m above the soil during 300 s. The rates of H * (10) varied from 33.1 to 152.3 nSv.h -1 , net values, obtained after subtraction of the cosmic rays contribution. The standard deviation was 22 n Sv.h -1 for an average for the city of Sao Paulo of 96.1(24) nSv.h -1 . In addition, average values of H * (10) rates for the city Health Divisions were calculated. Those values are not statistically equivalent and the whole set of data could not be treated as one, as the statistical Student test indicated a non homogeneity of the group of data. Hence it is necessary the accomplishment of a more detailed survey in order to verify the origin of the discrepancy. The mean value of H * (10) rate obtained for the city of Sao Paulo as converted to effective dose. in order to be compared with other places results It could be noticed that the annual average of effective dose for the city of Sao Paulo, 0.522(13) mSv, is superior to

  3. Calorific energy deposited by gamma radiations in a test reactor. Calorimetric measurements and calculations

    International Nuclear Information System (INIS)

    Mecheri, K.-F.

    1977-01-01

    The purpose of this work was to determine the calorific energy deposited by gamma radiations in the experimental devices irradiated in the test reactors of the Grenoble Nuclear Study Centre. A theoretical study briefly recalls to mind the various sorts of nuclear reactions that occur in a reactor, from the special angle of their ability to deposit calorific energy in the materials. A special study with the help of a graphite calorimeter made it possible to show the possible effect of the various parameters intervening in this energy absorption: the nature of the materials, their geometry, the spectrum of the incident gamma rays and the fact that the variation of this spectrum is due to the position of the measuring point with respect to the reactor core or to the presence of structures around the measuring instrument. The results of the calculations made with the help of the Mercury IV and ANISN codes are compared with those of the determinations in order to ascertain that very are adapted to the forecasts of energy deposition in the various materials. The conclusion was reached that in order to calculate with accuracy the depositifs of gamma energy in the experimental devices, it is necessary either to introduce the build-up calculation for the low energy photons, in the Mercury IV calculation code or to associate the DOT code to the ANISN calculation code [fr

  4. Gamma radiation in dwellings

    International Nuclear Information System (INIS)

    Mjoenes, L.

    1981-08-01

    A nationwide investigation has been made into the gamma radiation in Swedish dwellings. The measurements were made with small detectors containing thermoluminescent dosimeters. The detectors were sent to the selected participants by mail. 1300 dwellings were included in the investigation. In each dwelling three measurements were made: one detector was placed in the kitchen, one in the living-room and one in the bedroom. The mean annual absorbed tissue dose in dwellings in Sweden was found to be 0.65 mGy (corresponding to an exposition rate of 12 μR/h) when the contribution from cosmic radiation had been subtracted. That represents an annual collective dose of about 4000 mansieverts to the population of Sweden. From a previous investigation we have calculate the mean value for the gamma radiation in Swedish dwellings for 1950 to be 0.4 mGy/a (8μR/h). The reason for the relatively large increase in the mean value is an increased use of building materials on stone, particularly of lightweight concrete based on alum shale, from 1940 to middle 1960s. The production of this type of lightweight concrete was discontinued in 1975 and the use of other stone-based building materials has decreased. The mean value of gamma radiation in Swedish dwellings is therefore expected to decrease slowly in the future if this tendency holds. Sweden has some 3.5 million dwellings. About 10 % of them have mean values of 1 mGy/a (19 μR/h) or more, 0.2 % have 3 mGy/a (57 μR/h) or more and a couple of hundred 5 mGy/a (95 μR/h or more. The mean value for detached houses was found to be 0.43 mGy/a (8 μR/h) and for dwellings in multi-family houses 0.80 mGy/a (15 μR/h). The investigation dwellings have also been classified according to the building materials, the year of construction and the degree of urbanization of the area. (author)

  5. Single-source gamma radiation procedures for improved calibration and measurements in porous media

    International Nuclear Information System (INIS)

    Oostrom, M.; Hofstee, C.; Dane, H.; Lenhard, R.J.

    1998-01-01

    When dual-energy gamma radiation systems are employed for measurements in porous media, count rates from both sources are often used to compute parameter values. However, for several applications, the count rates of just one source are insufficient. These applications include the determination of volumetric liquid content values in two-liquid systems and salt concentration values in water-saturated porous media. Single-energy gamma radiation procedures for three applications are described in this paper. Through an error analysis, single-source procedures are shown to reduce the probable error in the determinations considerably. Example calculations and simple column experiments were conducted for each application to compare the performance of the new single-source and standard dual-source methods. In all cases, the single-source methods provided more reliable data than the traditional dual-source methods. In addition, a single-source calibration procedure is proposed to determine incident count rates indirectly. This procedure, which requires packing under saturated conditions, can be used in all single- and dual-source applications and yields accurate porosity and dry bulk density values

  6. Using RADFET for the real-time measurement of gamma radiation dose rate

    Science.gov (United States)

    Andjelković, Marko S.; Ristić, Goran S.; Jakšić, Aleksandar B.

    2015-02-01

    RADFETs (RADiation sensitive Field Effect Transistors) are integrating ionizing radiation dosimeters operating on the principle of conversion of radiation-induced threshold voltage shift into absorbed dose. However, one of the major drawbacks of RADFETs is the inability to provide the information on the dose rate in real-time using the conventional absorbed dose measurement technique. The real-time monitoring of dose rate and absorbed dose can be achieved with the current mode dosimeters such as PN and PIN diodes/photodiodes, but these dosimeters have some limitations as absorbed dose meters and hence they are often not a suitable replacement for RADFETs. In that sense, this paper investigates the possibility of using the RADFET as a real-time dose rate meter so that it could be applied for simultaneous online measurement of the dose rate and absorbed dose. A RADFET sample, manufactured by Tyndall National Institute, Cork, Ireland, was tested as a dose rate meter under gamma irradiation from a Co-60 source. The RADFET was configured as a PN junction, such that the drain, gate and source terminals were grounded, while the radiation-induced current was measured at the bulk terminal, whereby the bulk was successively biased with 0 , 10 , 20  and 30 V. In zero-bias mode the radiation-induced current was unstable, but in the biased mode the current response was stable for the investigated dose rates from 0.65  to 32.1 Gy h-1 and up to the total absorbed dose of 25 Gy. The current increased with the dose rate in accordance with the power law, whereas the sensitivity of the current read-out was linear with respect to the applied bias voltage. Comparison with previously analyzed PIN photodiodes has shown that the investigated RADFET is competitive with PIN photodiodes as a gamma radiation dose rate meter and therefore has the potential to be employed for the real-time monitoring of the dose rate and absorbed dose.

  7. Using RADFET for the real-time measurement of gamma radiation dose rate

    International Nuclear Information System (INIS)

    Andjelković, Marko S; Ristić, Goran S; Jakšić, Aleksandar B

    2015-01-01

    RADFETs (RADiation sensitive Field Effect Transistors) are integrating ionizing radiation dosimeters operating on the principle of conversion of radiation-induced threshold voltage shift into absorbed dose. However, one of the major drawbacks of RADFETs is the inability to provide the information on the dose rate in real-time using the conventional absorbed dose measurement technique. The real-time monitoring of dose rate and absorbed dose can be achieved with the current mode dosimeters such as PN and PIN diodes/photodiodes, but these dosimeters have some limitations as absorbed dose meters and hence they are often not a suitable replacement for RADFETs. In that sense, this paper investigates the possibility of using the RADFET as a real-time dose rate meter so that it could be applied for simultaneous online measurement of the dose rate and absorbed dose. A RADFET sample, manufactured by Tyndall National Institute, Cork, Ireland, was tested as a dose rate meter under gamma irradiation from a Co-60 source. The RADFET was configured as a PN junction, such that the drain, gate and source terminals were grounded, while the radiation-induced current was measured at the bulk terminal, whereby the bulk was successively biased with 0 , 10 , 20  and 30 V. In zero-bias mode the radiation-induced current was unstable, but in the biased mode the current response was stable for the investigated dose rates from 0.65  to 32.1 Gy h −1 and up to the total absorbed dose of 25 Gy. The current increased with the dose rate in accordance with the power law, whereas the sensitivity of the current read-out was linear with respect to the applied bias voltage. Comparison with previously analyzed PIN photodiodes has shown that the investigated RADFET is competitive with PIN photodiodes as a gamma radiation dose rate meter and therefore has the potential to be employed for the real-time monitoring of the dose rate and absorbed dose. (paper)

  8. Gamma radiation shielding and optical properties measurements of zinc bismuth borate glasses

    International Nuclear Information System (INIS)

    Yasaka, P.; Pattanaboonmee, N.; Kim, H.J.; Limkitjaroenporn, P.; Kaewkhao, J.

    2014-01-01

    Highlights: • 10ZnO:xBi 2 O 3 :(90−x)B 2 O 3 , (ZBB) glasses were prepared. • Radiation shielding and optical properties were investigated. • Higher 25 mol% of Bi 2 O 3 show better shielding property compared with concretes. • ZBB glasses can develop as a Pb-free radiation shielding material. - Abstract: In this work, the zinc bismuth borate (ZBB) glasses of the composition 10ZnO:xBi 2 O 3 :(90−x)B 2 O 3 (where x = 15, 20, 25 and 30 mol%) were prepared by the melt quenching technique. Their radiation shielding and optical properties were investigated and compared with theoretical calculations. The mass attenuation coefficients of ZBB glasses have been measured at different energies obtained from a Compton scattering technique. The results show a decrease of the mass attenuation coefficient, effective atomic number and effective electron density values with increasing of gamma-ray energies; and good agreements between experimental and theoretical values. The glass samples with Bi 2 O 3 concentrations higher than 25 mol% (25 and 30 mol%) were observed with lower mean free path (MFP) values than all the standard shielding concretes studied. These results are indications that the ZBB glasses in the present study may be developed as a lead-free radiation shielding material in the investigated energy range

  9. Environmental gamma radiation measurements over the Bay of Bengal around Kalpakkam and in Chennai Harbor

    International Nuclear Information System (INIS)

    Surya Prakash, G.; Baskaran, R.; Venkatraman, B.; Rajagopal, V.; Mohanty, Ajit Kumar

    2012-01-01

    DAE site Kalpakkam, encompassing several operating nuclear facilitates is enclosed in a strip of land between the Bay of Bengal on the east and Buckingham Canal on the west. Approximately about 50% of the Emergency Prone Zone (EPZ) area around the plant lies in the Bay of Bengal. The radiation levels around Kalpakkam nuclear complex is monitored by Environmental Survey Laboratory (ESL) at Kalpakkam. The survey has been carried out up to 16 km in the land areas. Though radioactivity levels in the seawater and the food produce derived from the sea are monitored and reported by ESL, data on the ambient radiation levels over the sea has not been reported. The paper describes the campaign based ambient gamma radiation level measurements done during the past few years. The radiation level measurements done at selected locations varied between 8 and 115 nGyh -1 (0.8 and 11.5 μRh -1 ) during the first campaign and 14 and 170 nGyh -1 (1.4 and 17 μRh -1 ) during the second campaign. The average dose rate observed from both the campaigns was 62 nGyh 1 (6.2 μRh -1 ). During the campaign period we are looked in to any interference from the 41 Ar released from the MAPS reactor also. The third campaign at the Chennai harbor (∼ 60 km north of Kalpakkam) the observed radiation levels were between 15 nGyh -1 (1.5 μRh -1 ) and 12.2 nGyh -1 (12.2 μRh -1 ). This paper discussed the details of the techniques and the measurement

  10. Gamma Radiation from Fission Fragments

    International Nuclear Information System (INIS)

    Higbie, Jack

    1969-10-01

    The gamma radiation from the fragments of the thermal neutron fission of 235 U has been investigated, and the preliminary data are presented here with suggestions for further lines of research and some possible interpretations of the data. The data have direct bearing on the fission process and the mode of fragment de-excitation. The parameters measured are the radiation decay curve for the time interval (1 - 7) x 10 -10 sec after fission, the photon yield, the total gamma ray energy yield, and the average photon energy. The last three quantities are measured as a function of the fragment mass

  11. Gamma Radiation from Fission Fragments

    Energy Technology Data Exchange (ETDEWEB)

    Higbie, Jack

    1969-10-15

    The gamma radiation from the fragments of the thermal neutron fission of {sup 235}U has been investigated, and the preliminary data are presented here with suggestions for further lines of research and some possible interpretations of the data. The data have direct bearing on the fission process and the mode of fragment de-excitation. The parameters measured are the radiation decay curve for the time interval (1 - 7) x 10{sup -10} sec after fission, the photon yield, the total gamma ray energy yield, and the average photon energy. The last three quantities are measured as a function of the fragment mass.

  12. Dosimetric evaluation of lithium carbonate (Li2CO3) as a dosemeter for gamma-radiation dose measurements.

    Science.gov (United States)

    Popoca, R; Ureña-Núñez, F

    2009-06-01

    This work reports the possibility of using lithium carbonate as a dosimetric material for gamma-radiation measurements. Carboxi-radical ions, CO(2)(-) and CO(3)(-), arise from the gamma irradiation of Li(2)CO(3), and these radical ions can be quantified by electron paramagnetic resonance (EPR) spectrometry. The EPR-signal response of gamma-irradiated lithium carbonate has been investigated to determine some dosimetric characteristics such as: peak-to-peak signal intensity versus gamma dose received, zero-dose response, signal fading, signal repeatability, batch homogeneity, dose rate effect and stability at different environmental conditions. Using the conventional peak-to-peak method of stable ion radicals, it is concluded that lithium carbonate could be used as a gamma dosemeter in the range of 3-100 Gy.

  13. Characterization of aqueous rose bengal dye solution for the measurement of low doses of gamma radiation

    International Nuclear Information System (INIS)

    Hasan Mahmood Khan; Khan, A.A.

    2010-01-01

    Aqueous solution of rose bengal dye has been studied spectrophotometrically as a gamma-ray dosimeter for the measurement of low doses of radiation. The useful dose range was found to be from 50 to 1000 Gy when the measurements were made at 549 nm. The effects of temperature and light conditions on the stability of response during post-irradiation storage were also investigated. When stored in dark at room temperature, the dosimetric solutions showed a stable response up to 22 days. The storage of irradiated solutions in diffused sunlight showed a stable response only up to 6 days. When exposed to direct sunlight, very prominent and fast bleaching of dye solution occurred. At low storage temperature (ca. 11 deg C), dosimetric response was found to be stable up to 22 days while at higher temperature (ca. 30 deg C), the response of dosimetric solution was stable only up to 6 days. The rose bengal aqueous solution showed promising characteristics as a low dose radiation dosimeter when stored at lower temperatures (<25 deg C) in dark. (author)

  14. Measurement of Inclusive Radiative B -Meson Decay B -> X_s gamma

    Energy Technology Data Exchange (ETDEWEB)

    Ozcan, V.E.; /SLAC /Stanford U., Appl. Phys. Dept.

    2006-01-06

    Radiative decays of the B meson, B {yields} X{sub s}{gamma}, proceed via virtual flavor changing neutral current processes that are sensitive to contributions from high mass scales, either within the Standard Model of electroweak interactions or beyond. In the Standard Model, these transitions are sensitive to the weak interactions of the top quark, and relatively robust predictions of the inclusive decay rate exist. Significant deviation from these predictions could be interpreted as indications for processes not included in the minimal Standard Model, like interactions of charged Higgs or SUSY particles. The analysis of the inclusive photon spectrum from B {yields} X{sub s}{gamma} decays is rather challenging due to high backgrounds from photons emitted in the decay of mesons in B decays as well as e{sup +}e{sup -} annihilation to low mass quark and lepton pairs. Based on 88.5 million B{bar B} events collected by the BABAR detector, the photon spectrum above 1.9 GeV is presented. By comparison of the first and second moments of the photon spectrum with QCD predictions (calculated in the kinetic scheme), QCD parameters describing the bound state of the b quark in the B meson are extracted: m{sub b} = (4.45 {+-} 0.16) GeV/c{sup 2}; {mu}{sub {pi}}{sup 2} = (0.65 {+-} 0.29) GeV{sup 2}. These parameters are useful input to non-perturbative QCD corrections to the semileptonic B decay rate and the determination of the CKM parameter |V{sub ub}|. Based on these parameters and heavy quark expansion, the full branching fraction is obtained as: {Beta}(B {yields} X{sub s}{gamma}){sup E{sub {gamma}}>1.6 GeV} = (4.05 {+-} 0.32(stat) {+-} 0.38(syst) {+-} 0.29(model)) x 10{sup -4}. This result is in good agreement with previous measurements, the statistical and systematic errors are comparable. It is also in good agreement with the theoretical Standard Model predictions, and thus within the present errors there is no indication of any interactions not accounted for in the

  15. Principle and methods for measurement of snow water equivalent by detection of natural gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Endrestoel, G O [Institutt for Atomenergi, Kjeller (Norway)

    1979-01-01

    The underlying principles for snow cover determination by use of terrestrial gamma radiation are presented. Several of the methods that have been proposed to exploit the effect are discussed, and some of the more important error sources for the different methods are listed. In conclusion an estimate of the precision that can be obtained by these methods is given.

  16. Principle and methods for measurement of snow water equivalent by detection of natural gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Endrestol, G O

    1979-01-01

    The underlying principles for snow cover determination by use of terrestrial gamma radiation are presented. Several of the methods that have been proposed to exploit the effect are discussed, and some of the more important error sources for the different methods are listed. In conclusion estimates of the precision that can be obtained by these methods are given.

  17. Measurements of the light conversion efficiency of lithium borate for alpha particles relative to cobalt-60 gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Bartlett, D.T.; Wall, B.F.; Fisher, E.S. (National Radiological Protection Board, Harwell (UK))

    1982-01-01

    The results are reported of measurements of the light conversion efficiencies of lithium borate TLD phosphor of British Nuclear Fuels Ltd. manufacture to 5.65 MeV and 2.4 MeV alpha particles relative to /sup 60/Co gamma radiation.

  18. Gamma radiation in apartments

    International Nuclear Information System (INIS)

    Grindborg, J.-E.

    1983-05-01

    This investigation forms the basis for the description of methods for the detection of gamma radiation. The aim is to control that the dose limit will not exceed 50 μR/h in a room where people reside. The distribution of dose rates in different rooms has been calculated and the results have been compared with experimental data. Various instruments have been calibrated and their specifications are discussed. (G.B.)

  19. Activation of the JET vacuum vessel: a comparison of calculated with measured gamma-radiation fluxes and dose rates

    International Nuclear Information System (INIS)

    Jarvis, O.N.; Sadler, G.; Avery, A.; Verschuur, K.A.

    1988-01-01

    The gamma-radiation dose-rates inside the JET vacuum vessel due to induced radioactivity were measured at intervals throughout the 1986 period of operation, and the decay gamma energy spectrum was measured during the subsequent lengthy shutdown. The dose-rates were found to be in good agreement with values calculated using the neutron yield records compiled from the time-resolved neutron yield monitor responses for individual discharges. This result provides strong support for the reliability of the neutron yield monitor calibration. (author)

  20. Environmental radiation monitoring: mobile gamma dose rate measurements along Mumbai-Hyderabad rail route and Hyderabad city roads

    International Nuclear Information System (INIS)

    Divkar, J.K.; Padmanabhan, N.; Chaudhury, Probal; Pradeepkumar, K.S.; Pujari, R.N.; Dogra, Santosh; Sharma, D.N.; Rajagopalan, S.; Srivastava, G.K.

    2005-01-01

    Environmental Radiation monitoring based on gamma dose rate logging on a mobile platform integrated with real time position from a Global Positioning System is an effective tool to acquire dose rate profile and generate radiological map of any geographical region. The microcontroller based dose rate data acquisition system capable of storing the acquired data and transferring to an attached laptop/PC and providing a graphical illustration of relative variations in gamma background can also be used for quick assessment of environmental radiological impact assessment. This paper describes the methodology and results of the environmental gamma dose rate monitoring surveys carried out: (i) on Mumbai-Hyderabad rail route with the systems installed in the trains guard's room and (ii) Hyderabad city roads with systems installed in a monitoring van. The results indicate significant difference in the gamma background measured along the rail route between Mumbai-Hyderabad and in the radiological map generated after the Hyderabad city survey. (author)

  1. Environmental gamma radiation and fallout measurements in Finland, 1986-87

    International Nuclear Information System (INIS)

    Arvela, H.; Markkanen, M.; Lemmelae, H.; Blomqvist, L.

    1989-07-01

    Results from a survey of environmental gamma radiation levels in Finland after the Chernobyl accident 1986 are presented. The measurements were made in 1986-87 by means of sensitive Geiger-counters and a gamma-spectrometer placed in cars. The results show the level of external radiation caused by the cesium fallout on the first of October 1987. The fallout pattern of 137 Cs as well as of 95 Zr and 103 Ru are also presented. In the center of Southern Finland there are wide areas with exposure levels exceeding 0.03 μSv h -1 , areas exceeding 0.10 μSv h -1 being very rare. The surface area weighted mean dose rate for the 461 municipalities in Finland was 0.027 μSv h -1 (range 0-0.19 μSv h -1 ). The population weighted mean dose rate was 0.037 μSv h -1 . The corresponding estimated surface activity of 137 Cs was 10.7 kBq m -2 . The passage of the Chernobyl plume over Finland in 1986 led to various fallout patterns for different radionuclides. The deposition of the non-volatile nuclides, 95 Zr and 141 Ce, is closely related to the passage of the hot particle dust formed at the initial explosion in the reactor at 01.23 LT on 26 April. This cloud passed over Finland between the morning and the night of 27 April. The deposition of volatile fission products such as 131 I, 132 Te, 134 Cs and 137 Cs in Finland was caused by releases from the burning reactor after the initial explosion. The radioactive plume spread over Southern and Central Finland between Sunday 27 April and Tuesday 29 April. On 30 April and finally on 1 May a could northerly airstream spread into the whole of Finland purifying the atmosphere. The volatile nuclides were mainly deposited by intermittent rain on 28-30 April. The deposition pattern of 103 Ru is a combination of the fallou patterns due to the initial explosion and the reactor burn, as well as the wet deposition occurring on 10-12 May caused by the releases from the burning reactor in early May

  2. Measurement of Cerenkov Radiation Induced by the Gamma-Rays of Co-60 Therapy Units Using Wavelength Shifting Fiber

    Directory of Open Access Journals (Sweden)

    Kyoung Won Jang

    2014-04-01

    Full Text Available In this study, a wavelength shifting fiber that shifts ultra-violet and blue light to green light was employed as a sensor probe of a fiber-optic Cerenkov radiation sensor. In order to characterize Cerenkov radiation generated in the developed wavelength shifting fiber and a plastic optical fiber, spectra and intensities of Cerenkov radiation were measured with a spectrometer. The spectral peaks of light outputs from the wavelength shifting fiber and the plastic optical fiber were measured at wavelengths of 500 and 510 nm, respectively, and the intensity of transmitted light output of the wavelength shifting fiber was 22.2 times higher than that of the plastic optical fiber. Also, electron fluxes and total energy depositions of gamma-ray beams generated from a Co-60 therapy unit were calculated according to water depths using the Monte Carlo N-particle transport code. The relationship between the fluxes of electrons over the Cerenkov threshold energy and the energy depositions of gamma-ray beams from the Co-60 unit is a near-identity function. Finally, percentage depth doses for the gamma-ray beams were obtained using the fiber-optic Cerenkov radiation sensor, and the results were compared with those obtained by an ionization chamber. The average dose difference between the results of the fiber-optic Cerenkov radiation sensor and those of the ionization chamber was about 2.09%.

  3. Measuring element for detection and dose measurement of gamma radiation and neutrons and manufacturing method for the measuring element

    International Nuclear Information System (INIS)

    Piesch, E.; John, W.

    1979-01-01

    The measuring element consists of a bubble-free glass composed on the basis of metaphosphate material. The detection of the γ-radiation takes place through the photoluminescence of the element, and detection of the neutrons by means of resulting β particles producing Cerenkov radiation in the radioluminescence material, that can be measured. For this purpose in addition to Ag the glass contains As as a second excitable element. (DG) [de

  4. Measurements of Background Gamma Radiation on Some Localities of North-East Kosovo

    OpenAIRE

    , G. Hodolli; , Y. Halimi; , R. Gashi; , Se. Kadiri; , B. Xhafa; , A. Jonuzaj

    2016-01-01

    The measurement of natural environmental radiations is one of the most important subjects in health physics. The main sources of background radiation are cosmic, terrestrial and cosmogenic radiation produced by reactions with cosmic rays and atmospheric nuclei. Terrestrial radiation varies in different regions in the world. Generally the background dose rate from cosmic rays depends on the latitude and altitude. The dose rate range obtained in some northeast Kosovo, the dose rate varies from ...

  5. EPR response of sucrose and microcrystalline cellulose to measure high doses of gamma radiation

    International Nuclear Information System (INIS)

    Torijano, E.; Cruz, L.; Gutierrez, G.; Azorin, J.; Aguirre, F.; Cruz Z, E.

    2015-10-01

    Solid dosimeters of sucrose and microcrystalline cellulose (Avicel Ph-102) were prepared, following the same process, in order to compare their EPR response against that of the l-alanine dosimeters considered as reference. All lots of dosimeters were irradiated with gamma radiation in Gamma beam irradiator with 8 kGy/h of the Nuclear Sciences Institute of UNAM. Doses ranged from 1 to 10 kGy respectively. We found that both the response of sucrose as microcrystalline cellulose were linear; however, the response intensity was, on average, twenty times more for sucrose. Comparing this against the EPR response of l-alanine in the range of doses, it was found that the response to sucrose is a third part; and microcrystalline cellulose is a sixtieth, approximately. The results agree with those found in the literature for sucrose, leaving open the possibility of investigating other dosage ranges for cellulose. (Author)

  6. Gamma radiation measurement, through a spark chamber put aboard of a stratospheric balloon

    International Nuclear Information System (INIS)

    Santo, C.M.E.; Rao, K.R.

    1982-06-01

    For determining the diffuse component of gamma rays in the 15 to 75 Mev range arriving from near the galactic center, a digitized spark chamber was launched aboard two balloons from Resende, Brazil, on 19 November and 3 December 1975. In each flight the detector reached an altitude of 2,2 g/cm 2 . Based on these data, a diffuse gamma ray flux 6,0x10 - 5 , 2,0x10 - 5 , 4,6x10 - 6 and 1,3x10 - 6 photons (cm 2 .s.sterad.Mev) at energies of 21, 36, 52, 67 Mev respectively was obtained. These values give a power law spectrum with spectral index equal to -3,3. The dependence of this radiation with the galactic latitude and longitude in the interval -5 0 0 and 325 0 0 was also obtained. Finally, our results were compared with other experiments' results. (Author) [pt

  7. An Attempt to Measure the Gamma Radiation Dosage at Hiroshima from Photosensitive Material

    Energy Technology Data Exchange (ETDEWEB)

    Brixner, Berlyn [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); McmIllan, Edwin [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Meade, Roger Allen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-09-23

    After Japan surrendered in August 1945, a team of Los Alamos scientists entered both Hiroshima and Nagasaki to assess the damage of Little Boy and Fat Man. Two of these scientists, Berlyn Brixner and Edwin McMillan, discovered a stock of photographic film in Hiroshima that had been fogged by the gamma radiation from Little Boy. They devised an experiment that they thought might be used to determine the exposure levels in the city. Below is both their description of the film stock and the attempt to determine the exposure levels at Hiroshima.

  8. In situ measurements in an immerged environment of ambient gamma radiation activity and associated spectrometry

    International Nuclear Information System (INIS)

    Metivier, J.

    1993-01-01

    A set of site measurement devices composed of an ictometer, an air ionization chamber and a gamma ray spectrometry chain was modified so that the type of measurements could be carried out in an immerged environment with the equipment lying on the sediments of the prospected area. The different detectors can be controlled-and the data stored in a portable and autonomous 'PC' microcomputer from a light craft

  9. Radiation measurement

    International Nuclear Information System (INIS)

    Go, Sung Jin; Kim, Seung Guk; No, Gyeong Seok; Park, Myeong Hwan; Ann, Bong Seon

    1998-03-01

    This book explains technical terms about radiation measurement, which are radiation, radiation quantity and unit such as prefix of international unit, unit for defence purposes of radiation, coefficient of radiation and interaction, kinds and principles of radiation detector, ionization chamber, G-M counter, G-M tube, proportional counter, scintillation detector, semiconductor radiation detector, thermoluminescence dosimeter, PLD, others detector, radiation monitor, neutron detector, calibration of radiation detector, statistics of counting value, activation analysis and electronics circuit of radiation detector.

  10. Gamma radiation and chickens

    International Nuclear Information System (INIS)

    Toropilova, D.; Takac, L.; Toropila, M.; Tomko, M. M.

    2014-01-01

    In our work, we focused the effect of low doses of gamma radiation on metabolic parameters in chickens. In the first group of chickens we monitor changes of the concentration in glucose and cholesterol after whole body irradiation dose of chicken (3 Gy). In the second group of chickens we studied the combined effect of radiation and intraperitoneal application solution of zinc chloride to changes of the concentration in glucose and total cholesterol. In the tissues of organisms are found only in a very small amount of microelements however are of particular importance in a number of enzymatic catalytic and regulatory processes. Zinc is found in all cells of the body. However, it is the highest percentage of zinc contained in muscle and bone cells. Resorption takes place in the small intestine, especially in the duodenum. For both groups of chickens, we performed analyzes on the 3 rd , 7 th , 14 th , 21 st and 30 day. Results and an overview of the work can be helpful in the peaceful uses of nuclear energy and in preventing diseases from exposure to radiation, but also in the case of the consequences after nuclear accidents. (authors)

  11. Absolute measurement of the responses of small lithium glass scintillators to gamma radiation

    International Nuclear Information System (INIS)

    Dalton, A.W.

    1987-04-01

    The absolute scintillation efficiency and intrinsic resolution of lithium glass scintillators for electron excitation have been determined over a range of electron energies, lithium concentrations and lithium enrichments. Measurements of these response characteristics form part of a study on the possible use of such glasses for the determination of tritium breeding in fusion reactor blanket experiments. The measurements were undertaken to establish a basis for extracting the information relating to tritium production reactions from the background signals induced within the glass scintillators by the neutron/gamma fields of a fusion reactor blanket. Criteria for the selection of glasses most suitable for tritium breeding measurements are discussed in tems of their observed responses

  12. Petrography, Gamma Radiation Measurements and Dose Rate, Northeastern Um Ara Area, South Eastern Desert, Egypt

    International Nuclear Information System (INIS)

    Moghazy, N.M.

    2016-01-01

    The northern part of Um Ara alkali feldspar micro granite has subjected to extensive post-magmatic metasomatic reworking resulting in development of amazonitized and albitized zones, reflecting K- and Na metasomatism leading to gross enrichment in U and Th towards the more evolved phases (e.g., albitized zones). Spectrometric survey data indicate that eU in Dokhan volcanics has the range of 2 to 42 ppm with an average value of 10 ppm and in monzogranites. It varies from 3 to 13 ppm with an average of 7 ppm while in alkali feldspar microgranites eU contents vary from 3 to 282 ppm with an average value of 30 ppm. The (eTh) contents in Dokhan volcanics ranges from 5-51 ppm with an average 18 ppm, in monzogranites their content was in the range of 11 to 47 ppm with an average value of 27 ppm where it ranges from 14 to 83 ppm with an average 46 ppm in alkali feldspar granite. The enhanced uranium content in altered zones was attributed to disseminated and fracture filling uranophane, autonite, in addition to other U and Th bearing minerals (such as columbite, zircon, monazite, xenotime and fluorite). Gamma-radiation dose rate and annual effective dose equivalents in mSv/y, Radium equivalent activity, external (H e x) and internal hazard index (H i n) and gamma activity index (Iγ) for all investigated samples were calculated to assess the potential radiation hazard for people living in dwellings made of the studied granites. Alkali feldspar granite activities would suggest that caution must be taken when using granites as building materials because they have radioactivity above the proposed acceptable level.

  13. Environmental gamma radiation measurements in Finland and the influence of the meteorological conditions after the Chernobyl accident in 1986

    International Nuclear Information System (INIS)

    Arvela, H.; Blomqvist, L.; Lemmelae, H.; Savolainen, A.L.; Sarkkula, S.

    1987-06-01

    Results from a survey of environmental gamma radiation levels in Finland after the Chernobyl accident 1986 were presented. The measurements were made by means of sensitive Geiger-counters and a gamma-spectrometer placed in cars. The results presented the level of external radiation caused by the cesium fallout on the first of October 1986. In the center of Southern Finland there are wide areas with exposure levels exceeding 0.04 μSv h -1 , areas exceeding 0.2 μSv h -1 being very rare. The surface area weighted mean dose rate for the 461 municipalities in Finland was 0.037 $mu$Sv h -1 (range 0-0.23 μSv h -1 ). The corresponding estimated surface activity of 137 Cs was 10.7 kBq m -2 . The population weighted mean dose rate was 0.051 μSv h -1 . Results from measurements at eight dose rate monitoring stations were presented as daily dose rate recordings in 1985-1986, the rate of decrease of the excess dose rate demonstrating quite large variations in the period from May to August. This indicated that the composition of the short-lived nuclides in the fallout varied from place to place. The influence of the meteorological conditions were reported with precipitation data from six days after the accident. There was a clear correlation between the results from precipitation and radiation measurements in different parts of Finland

  14. Gamma radiation measurement in select sand samples from Camburi beach - Vitoria, Espirito Santo, Brazil: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Barros, Livia F.; Pecequilo, Brigitte R.S.; Aquino, Reginaldo R., E-mail: lfbarros@ipen.b, E-mail: brigitte@ipen.b, E-mail: raquino@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    The variation of natural radioactivity along the surface of the beach sands of Camburi, located in Vitoria, capital of Espirito Santo, southeastern Brazil, was determined from the contents of {sup 226}Ra, {sup 232}Th and {sup 40}K. Eleven collecting points was selected along all the 6 km extension of the Camburi beach. Sand samples collected from all established points on January 2011 were dried and sealed in standard 100 mL polyethylene flasks and measured by high resolution gamma spectrometry after a 4 weeks ingrowth period, in order to allow the secular equilibrium in the {sup 238}U and {sup 232}Th series. The {sup 226}Ra concentration was determined from the weighted average concentrations of {sup 214}Pb and {sup 214}Bi. The {sup 232}Th concentration was determined from the weighted average concentrations of {sup 228}Ac, {sup 212}Pb and {sup 212}Bi and the {sup 40}K from its single gamma transition. Preliminary results show activity concentrations varying from 5 Bq.kg{sup -1} to {sup 222} Bq.kg{sup -1} for {sup 226}Ra and from 14 Bq.kg{sup -1} to 1074 Bq.kg{sup -'}1 for {sup 232}Th, both with the highest values for Camburi South and Central. For {sup 40}K, the activity concentrations ranged from 14 Bq.kg{sup -1} to 179 Bq.kg{sup -1} and the highest values were obtained for Camburi South. (author)

  15. Gamma radiation measurement in select sand samples from Camburi beach - Vitoria, Espirito Santo, Brazil: preliminary results

    International Nuclear Information System (INIS)

    Barros, Livia F.; Pecequilo, Brigitte R.S.; Aquino, Reginaldo R.

    2011-01-01

    The variation of natural radioactivity along the surface of the beach sands of Camburi, located in Vitoria, capital of Espirito Santo, southeastern Brazil, was determined from the contents of 226 Ra, 232 Th and 40 K. Eleven collecting points was selected along all the 6 km extension of the Camburi beach. Sand samples collected from all established points on January 2011 were dried and sealed in standard 100 mL polyethylene flasks and measured by high resolution gamma spectrometry after a 4 weeks ingrowth period, in order to allow the secular equilibrium in the 238 U and 232 Th series. The 226 Ra concentration was determined from the weighted average concentrations of 214 Pb and 214 Bi. The 232 Th concentration was determined from the weighted average concentrations of 228 Ac, 212 Pb and 212 Bi and the 40 K from its single gamma transition. Preliminary results show activity concentrations varying from 5 Bq.kg -1 to 222 Bq.kg -1 for 226 Ra and from 14 Bq.kg -1 to 1074 Bq.kg -' 1 for 232 Th, both with the highest values for Camburi South and Central. For 40 K, the activity concentrations ranged from 14 Bq.kg -1 to 179 Bq.kg -1 and the highest values were obtained for Camburi South. (author)

  16. Gamma radiation measurements in F-18 production in the RDS-111 Cyclotron from the Nuclear Engineering Institute

    International Nuclear Information System (INIS)

    Taam, Ilka H.; Bellido, Luis F.; Vinagre Filho, Ubirajara M.

    2005-01-01

    With the acquisition of RDS-111 particle accelerator, the Institute of Nuclear Engineering in Rio de Janeiro city (IEN) operates a new cyclotron to produce 1 8F to obtain the fluorodeoxyglucose (FDG), a radiopharmaceutical used in positron emission tomography (PET), a technique well advanced which allows obtaining images with high resolution for diagnoses in medicine. To evaluate and detect the gamma exposure during 1 8F production, in the routine operation, i.e. current of 30 μA and the operating time 120 minutes, it was used a portable detector hyperpure germanium (HPGe) coupled to an electronic system for acquisition of 4096 data channels. To obtain a wide energy spectrum from 0.1 to 20 MeV were performed measurements with different gains of amplification. The energy average of gamma radiation, calculated from the energy spectra of gamma rays obtained, was 1.59 ± 0.05 MeV. Meanwhile, measurements were made with a MIR 7026 monitor and with thermoluminescent detectors (TLD) of LiF: Mg, Cu, P to calculate the dose equivalent rates H * (10) of the installation

  17. Study of the gamma radiation of ionium

    Energy Technology Data Exchange (ETDEWEB)

    Curie, I

    1949-12-01

    A Geiger counter study has been made of the ..gamma.. radiation of ionium. Eleven quanta of the L radiation of radium were observed for every hundred ..cap alpha.. disintegrations, and three ..gamma.. rays were found with energies of 68, 140, and 240 keV at a rate of 0.85, 0.33, 0.05 quanta, respectively, for 100 disintegrations. It is noted that the radiation spectrum of ionium as a whole is difficult to interpret. In the course of this work, the author calculated the efficiency of a thin-walled aluminum counter, both for the L radiation of radium and for ..gamma.. rays of 68 keV. The author also measured, for soft radiation, the ratio between the efficiency of a thin-walled aluminum counter and that of a similar counter lined with 0.11 mm of lead.

  18. Measurement of the X and gamma radiation after muon-catalyzed pd-, dd-, and dt-fusion

    International Nuclear Information System (INIS)

    Bossy, H.

    1987-01-01

    The muonic X radiation emitted after muon-catalyzed fusion of two hydrogen nuclei has been measured for the fusion reactions of pd, dd, and dt (p=proton, d=deuteron, t=triton). The quantum yields (per fusion) of the μHe(2-1) transition were evaluated to be 3.2(4)% (pd fusion), 1.6(2)% (dd fusion), and 0.21(5)% (dt fusion, preliminary value). The intensity ratios of the transitions μHe(3-1)/μHe(2-1) were found to be 0.052(5) (pd fusion) and 0.13(2) (dd fusion). The investigation of the gamma radiation intensities for pd fusion yielded excitement probabilities of the μHe atom. (orig.) [de

  19. Gamma irradiators for radiation processing

    International Nuclear Information System (INIS)

    2006-01-01

    Radiation technology is one of the most important fields which the IAEA supports and promotes, and has several programmes that facilitate its use in the developing Member States. In view of this mandate, this Booklet on 'Gamma Irradiators for Radiation Processing' is prepared which describes variety of gamma irradiators that can be used for radiation processing applications. It is intended to present description of general principles of design and operation of the gamma irradiators available currently for industrial use. It aims at providing information to industrial end users to familiarise them with the technology, with the hope that the information contained here would assist them in selecting the most optimum irradiator for their needs. Correct selection affects not only the ease of operation but also yields higher efficiency, and thus improved economy. The Booklet is also intended for promoting radiation processing in general to governments and general public

  20. Observation of galactic gamma radiation

    International Nuclear Information System (INIS)

    Paul, J.A.

    1982-09-01

    A complete and deep survey of the galactic high-energy gamma radiation is now available, thanks to the gamma-ray telescopes on board of the SAS-2 and COS-B spacecrafts. A comparison of the COS-B gamma-ray survey with a fully sampled CO survey together with an Hsub(I) survey is used to show that a simple model, in which uniformly distributed cosmic rays interact with the interstellar gas, can account for almost all the gamma-ray emission observed in the first galactic quadrant. At medium galactic latitudes, it is shown that a relationship exists between the gamma radiation and the interstellar absorption derived from galaxy counts. Therefore gamma rays from the local galactic environment can be used as a valuable probe of the content and structure of the local interstellar medium. The large scale features of the local interstellar gas are revealed, in particular wide concentrations of nearby molecular hydrogen. On a smaller scale, the detection of numerous localized gamma-ray sources focuses the attention on some particular phases of clusters of young and massive stars where diffuse processes of gamma-ray emission may also be at work

  1. Ore sorting using natural gamma radiation

    International Nuclear Information System (INIS)

    Clark, G.J.; Dickson, B.L.; Gray, F.E.

    1980-01-01

    A method of sorting an ore which emits natural gamma radiation is described, comprising the steps of: (a) mining the ore, (b) placing, substantially at the mining location, the sampled or mined ore on to a moving conveyor belt, (c) measuring the natural gamma emission, water content and mass of the ore while the ore is on the conveyor belt, (d) using the gamma, water content and mass measurements to determine the ore grade, and (e) directing the ore to a location characteristic of its grade when it leaves the conveyor belt

  2. Laboratory for Calibration of Gamma Radiation Measurement Instruments (LabCal) of Institute of Chemical, Biological, Radiological and Nuclear Defense (IDQBRN) from Brazilian Army Technology Center (CTEx)

    International Nuclear Information System (INIS)

    Amorim, Aneuri de; Balthar, Mario Cesar V.; Santos, Avelino; Vilela, Paulo Ricardo T. de; Oliveira, Luciano Santa Rita; Penha, Paulo Eduardo C. de Oliveira; Gonzaga, Roberto Neves; Andrade, Edson Ramos de; Oliveira, Celio Jorge Vasques de; Fagundes, Luiz Cesar S.

    2016-01-01

    This paper describes the calibration laboratory deployment steps (LABCAL) gamma ionizing radiation measuring instruments in the Army Technology Center, CTEx. Initially the calibration of radiation monitors will be held in the dosimetric quantity air kerma and operational quantity ambient dose equivalent H*(d). The LABCAL / CTEx has not yet authorized by CASEC / CNEN. This laboratory aims to calibrate the ionizing radiation instruments used by the Brazilian Army. (author)

  3. Measurement of the circular polarization of gamma radiation from heavy ion collisions

    International Nuclear Information System (INIS)

    Lauterbach, C.

    1981-01-01

    For the nuclear reactions 16 O + 27 Al, 16 O + 58 Ni, 16 O + 62 Ni, 40 Ar + sup(nat)Ag, 86 Kr + sup(nat)Ag, and 86 Kr + 197 Au at incident energies of about 7 MeV/nucleon the circular polarization of the #betta# radiation emitted by the reaction products was measured. The projectile - like reaction products were detected by a δE-E telescope at a fixed angle of 35 0 relative to the beam axis. It is shown that the sign of the scattering angle for the classical orbit of the reaction partners can be determined by the experimental detection of circularly polarized #betta#-radiation from the decay of the highly excited reaction products. In the performed experiments for the first time extensive polarization phenomena in deep inelastic reactions were observed. The dominance of negative scattering angles was verified for a large range of light and medium-heavy systems. The results are compared with the predictions of theoretical models in which statistical or quantum mechanical fluctuations of the dynamical quantities are regarded. (orig./HSI) [de

  4. Some factors affecting urokinase inactivation. [Gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Iwata, Hiroo; Iketa, Yoshito

    1985-10-01

    The enzymatic activity of urokinase adsorbed on various polymer surfaces was measured to study the interaction between protein and polymers. The polymer films on which urokinase was adsorbed were exposed to either a high temperature or ..gamma..-radiation. The thermal inactivation rates were higher on hydrophobic polymers such as poly(ethylene terephthalate), nylon 6, and poly(vinylidene fluoride) than hydrophilic polymers like cellulose and ethylene-vinyl alcohol copolymer, indicating their substantial dependence on the interfacial free energy between the polymer and water. A similar dependence was also seen for the ..gamma..-radiation inactivation. Urokinase adsorbed on the hydrophobic polymers lost more easily its enzymatic activity by exposure to ..gamma..-radiation. The interfacial free energy seems to be one of the driving forces to denaturate proteins on polymers.

  5. Residual water treatment for gamma radiation

    International Nuclear Information System (INIS)

    Mendez, L.

    1990-01-01

    The treatment of residual water by means of gamma radiation for its use in agricultural irrigation is evaluated. Measurements of physical, chemical, biological and microbiological contamination indicators were performed. For that, samples from the treatment center of residual water of San Juan de Miraflores were irradiated up to a 52.5 kGy dose. The study concludes that gamma radiation is effective to remove parasites and bacteria, but not for removal of the organic and inorganic matter. (author). 15 refs., 3 tabs., 4 figs

  6. Quantifying K, U and Th contents of marine sediments using shipboard natural gamma radiation spectra measured on DV JOIDES Resolution

    Science.gov (United States)

    De Vleeschouwer, David; Dunlea, Ann G.; Auer, Gerald; Anderson, Chloe H.; Brumsack, Hans; de Loach, Aaron; Gurnis, Michael C.; Huh, Youngsook; Ishiwa, Takeshige; Jang, Kwangchul; Kominz, Michelle A.; März, Christian; Schnetger, Bernhard; Murray, Richard W.; Pälike, Heiko; Expedition 356 shipboard scientists, IODP

    2017-04-01

    During International Ocean Discovery Program (IODP) expeditions, shipboard-generated data provide the first insights into the cored sequences. The natural gamma radiation (NGR) of the recovered material, for example, is routinely measured on the ocean drilling research vessel DV JOIDES Resolution. At present, only total NGR counts are readily available as shipboard data, although full NGR spectra (counts as a function of gamma-ray energy level) are produced and archived. These spectra contain unexploited information, as one can estimate the sedimentary contents of potassium (K), thorium (Th), and uranium (U) from the characteristic gamma-ray energies of isotopes in the 40K, 232Th, and 238U radioactive decay series. Dunlea et al. [2013] quantified K, Th and U contents in sediment from the South Pacific Gyre by integrating counts over specific energy levels of the NGR spectrum. However, the algorithm used in their study is unavailable to the wider scientific community due to commercial proprietary reasons. Here, we present a new MATLAB algorithm for the quantification of NGR spectra that is transparent and accessible to future NGR users. We demonstrate the algorithm's performance by comparing its results to shore-based inductively coupled plasma-mass spectrometry (ICP-MS), inductively coupled plasma-emission spectrometry (ICP-ES), and quantitative wavelength-dispersive X-ray fluorescence (XRF) analyses. Samples for these comparisons come from eleven sites (U1341, U1343, U1366-U1369, U1414, U1428-U1430, U1463) cored in two oceans during five expeditions. In short, our algorithm rapidly produces detailed high-quality information on sediment properties during IODP expeditions at no extra cost. Dunlea, A. G., R. W. Murray, R. N. Harris, M. A. Vasiliev, H. Evans, A. J. Spivack, and S. D'Hondt (2013), Assessment and use of NGR instrumentation on the JOIDES Resolution to quantify U, Th, and K concentrations in marine sediment, Scientific Drilling, 15, 57-63.

  7. Concrete for. gamma. radiation shielding

    Energy Technology Data Exchange (ETDEWEB)

    de Azevedo e Souza, A.C. (Rio de Janeiro Univ. (Brazil). Inst. de Quimica); Rogers, J D [Rio de Janeiro Univ. (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia

    1980-06-01

    The attenuation characteristics of ..gamma.. radiation in concrete slabs, considering their mechanical resistence and densities were determined. One heavy concrete which was used, was prepared using as additives iron ore and Fe/sub 2/ O/sub 3/ pellets in various grain sizes. Fortran programs were used for analysing data and determining the absorption coefficients and attenuation factors.

  8. Terrestrial Gamma Radiation Exposure Measurement and Risk Estimates in the Environments of Major Industries In Ota, Nigeria

    Directory of Open Access Journals (Sweden)

    Abodunrin Oluwasayo Peter

    2016-11-01

    Full Text Available When fast estimates are required, the in-situ method is more appropriate as this allows for quick results; preventing further exposure of the public and permitting quick intervention. Measurements of the terrestrial gamma radiation exposure have been carried out in the environments of major industries in Ota using a portable survey meter. The motivation for this study resulted from the uncertainty in the general public opinion on the effect of the presence, and activities of some of these industries in their environment. Measurements were taken twice daily within the vicinity of each industry to determine the dose levels. The mean values obtained range from 0.11 – 1.80 µSv/h. These values are within the results obtained from normal background areas except for site number 10. Annual effective dose values range from 0.25 – 5.21 mSv with a mean value of 1.21 mSv. Routine activities in some of these environments may have contributed significantly to the ambient natural background radiation resulting in high values as obtained in some of these locations. The total risks disparately estimated for cancer and genetic effects resulting from the results obtained range from 0.17 x 10-4 – 3.80 x 10-4 with a mean value of 0.94 x 10-4. These levels are within the range of the average annual risk for accidental death for all industries.

  9. Detection unit for measuring dose rate and/or dose of gamma radiation

    International Nuclear Information System (INIS)

    Viererbl, L.

    1987-01-01

    A detection unit is designed consisting of a scintillation detector of the NaI(Tl) type on which there is a correction filter. The filter is an aluminium case in which are placed alternately side by side lead and iron absorption layers. The sensitivity of the detector with this filter is constant for gamma energy within the range 50 to 1300 keV. (M.D.). 2 figs

  10. Automated TLD system for gamma radiation monitoring

    International Nuclear Information System (INIS)

    Nyberg, P.C.; Ott, J.D.; Edmonds, C.M.; Hopper, J.L.

    1979-01-01

    A gamma radiation monitoring system utilizing a commercially available TLD reader and unique microcomputer control has been built to assess the external radiation exposure to the resident population near a nuclear weapons testing facility. Maximum use of the microcomputer was made to increase the efficiency of data acquisition, transmission, and preparation, and to reduce operational costs. The system was tested for conformance with an applicable national standard for TLD's used in environmental measurements

  11. Consideration of the problems of the separate measurement of {beta}, {gamma} and X radiation; Considerations sur les problemes de la dosimetrie individuelle des radiations {beta}, {gamma}, X

    Energy Technology Data Exchange (ETDEWEB)

    Joffre, H [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-07-01

    After outlining the present state of knowledge concerning the determination of doses absorbed by external irradiation for various types of radiation, the author gives figures for the comparative sensitivity of common detectors. He then defines the criteria which have to be considered for the choice of the sensitive medium and of the nature and the thickness of the detector walls. Considered very generally, the detection assembly intended for measuring the dose absorbed at a given point in the organism must be designed with a view to giving the same overall interactions with the radiation considered as those occurring in the organism. (author) [French] Apres avoir precise l'etat de nos connaissances generales actuelles concernant la determination des doses absorbees par irradiation externe pour les divers rayonnements, l'auteur indique la sensibilite comparee des detecteurs usuels. Il definit ensuite les criteres qui doivent etre pris en consideration pour le choix du milieu sensible, de la nature et de l'epaisseur de la paroi des detecteurs. D'une maniere tres generale, l'ensemble de detection destine a mesurer une dose absorbee en un point donne de l'organisme doit etre concu en vue de presenter les memes interactions globales avec le rayonnement etudie que celles mises en jeu dans l'organisme. (auteur)

  12. Measurement of the wetting profile in concrete samples with vertical water by gamma radiation transmission method

    International Nuclear Information System (INIS)

    Silva, L.M. da; Rocha, M.C. da; Appoloni, C.R.; Portezan Filho, O.; Lopes, F.; Melquiades, F.L.; Santos, E.A. dos; Santos, A.O. dos; Moreira, A.C.; Poetker, W.E.; Almeida, E. de; Tannous, C.Q.; Kuramoto, R.; Cavalcante, F.H. de M.; Barbieri, P.F.

    2000-01-01

    Samples of concrete for popular habitation (0,1x0,03x0,1 m) and cellular concrete (0,1x0,05x0,1 m) were submitted to water vertical ascending infiltration. The moisture content spatial and temporal evolution of each sample it was monitored in three halfway positions in a same horizontal line, applying the gamma rays transmission method. The data were taken with a 137 Cs (3,7x10 10 Bq, 0662 MeV) source, NaI (Tl) of 2x2' detector coupled to between wetting profiles and concrete strength. The cellular concrete showed a wetting profile compatible to its greater porosity. (author)

  13. Cosmic gamma-ray background radiation. Current understandings and problems

    International Nuclear Information System (INIS)

    Inoue, Yoshiyuki

    2015-01-01

    The cosmic gamma-ray background radiation is one of the most fundamental observables in the gamma-ray band. Although the origin of the cosmic gamma-ray background radiation has been a mystery for a long time, the Fermi gamma-ray space telescope has recently measured it at 0.1-820 GeV and revealed that the cosmic GeV gamma-ray background is composed of blazars, radio galaxies, and star-forming galaxies. However, Fermi still leaves the following questions. Those are dark matter contribution, origins of the cosmic MeV gamma-ray background, and the connection to the IceCube TeV-PeV neutrino events. In this proceeding, I will review the current understandings of the cosmic gamma-ray background and discuss future prospects of cosmic gamma-ray background radiation studies. (author)

  14. Gamma radiation shielding analysis of lead-flyash concretes

    International Nuclear Information System (INIS)

    Singh, Kanwaldeep; Singh, Sukhpal; Dhaliwal, A.S.; Singh, Gurmel

    2015-01-01

    Six samples of lead-flyash concrete were prepared with lead as an admixture and by varying flyash content – 0%, 20%, 30%, 40%, 50% and 60% (by weight) by replacing cement and keeping constant w/c ratio. Different gamma radiation interaction parameters used for radiation shielding design were computed theoretically and measured experimentally at 662 keV, 1173 keV and 1332 keV gamma radiation energy using narrow transmission geometry. The obtained results were compared with ordinary-flyash concretes. The radiation exposure rate of gamma radiation sources used was determined with and without lead-flyash concretes. - Highlights: • Concrete samples with lead as admixture were casted with flyash replacing 0%, 20%, 30%, 40%, 50% and 60% of cement content (by weight). • Gamma radiation shielding parameters of concretes for different gamma ray sources were measured. • The attenuation results of lead-flyash concretes were compared with the results of ordinary flyash concretes

  15. Effects of gamma radiation in soybean

    International Nuclear Information System (INIS)

    Franco, Jose Gilmar; Franco, Suely Salumita Haddad; Arthur, Valter; Arthur, Paula Bergamin; Franco, Caio Haddad

    2015-01-01

    The degree of radiosensitivity depends mostly on the species, the stage of the embryo at irradiation, the doses employed and the criteria used to measure the effect. One of the most common criteria to evaluate radiosensitivity in seeds is to measure the average plant production. Soya dry seeds were exposed to low doses of gamma radiation from source of Cobalt-60, type Gammecell-220, at 0.245 kGy dose rate. In order to study stimulation effects of radiation on germination, plant growth and production. Five treatments radiation doses were applied as follows: 0 (control); 25; 50; 75 and 100 Gy. Seed germination and harvest of number of seeds and total production were assessed to identify occurrence of stimulation. Soya seeds and plants were handled as for usual seed production in Brazil. The low doses of gamma radiation in the seeds that stimulate the production were doses of 25, 50 and 75 Gy. There are evidences that the use of low doses of gamma radiation can stimulate germination and plant production. (author)

  16. Effects of gamma radiation in soybean

    Energy Technology Data Exchange (ETDEWEB)

    Franco, Jose Gilmar; Franco, Suely Salumita Haddad; Arthur, Valter; Arthur, Paula Bergamin, E-mail: arthur@cena.usp.br [Centro de Energia Nuclear na Agricultura (CENA/USP), Piracicaba, SP (Brazil); Franco, Caio Haddad [Centro Nacional de Pesquisa em Energia e Materiais (LNBio/CNPEM), Campinas, SP (Brazil). Laboratorio Nacional de Biociencias; Villavicencio, Anna Lucia, E-mail: zegilmar60@gmail.com, E-mail: gilmita@uol.com.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    The degree of radiosensitivity depends mostly on the species, the stage of the embryo at irradiation, the doses employed and the criteria used to measure the effect. One of the most common criteria to evaluate radiosensitivity in seeds is to measure the average plant production. Soya dry seeds were exposed to low doses of gamma radiation from source of Cobalt-60, type Gammecell-220, at 0.245 kGy dose rate. In order to study stimulation effects of radiation on germination, plant growth and production. Five treatments radiation doses were applied as follows: 0 (control); 25; 50; 75 and 100 Gy. Seed germination and harvest of number of seeds and total production were assessed to identify occurrence of stimulation. Soya seeds and plants were handled as for usual seed production in Brazil. The low doses of gamma radiation in the seeds that stimulate the production were doses of 25, 50 and 75 Gy. There are evidences that the use of low doses of gamma radiation can stimulate germination and plant production. (author)

  17. Low doses of gamma radiation in soybean

    International Nuclear Information System (INIS)

    Franco, José G.; Franco, Suely S.H.; Villavicencio, Anna L.C.; Arthur, Valter; Arthur, Paula B.; Franco, Caio H.

    2017-01-01

    The degree of radiosensitivity depends mostly on the species, the stage of the embryo at irradiation, the doses employed and the criteria used to measure the effect. One of the most common criteria to evaluate radiosensitivity in seeds is to measure the average plant production. Dry soya seeds were exposed to low doses of gamma radiation from source of Cobalt-60, type Gammecell-220, at 0.210 kGy dose rate. In order to study stimulation effects of radiation on germination, plant growth and production. A treatment with four radiation doses was applied as follows: 0 (control); 12.5; 25.0 and 50.0 Gy. Seed germination and harvested of number of seeds and total production were assessed to identify occurrence of stimulation. Soya seeds number and plants were handled as for usual seed production in Brazil. The low doses of gamma radiation in the seeds that stimulate the production were the doses of 12.5 and 50.0 Gy. The results show that the use of low doses of gamma radiation can stimulate germination and plant production. (author)

  18. Low doses of gamma radiation in soybean

    Energy Technology Data Exchange (ETDEWEB)

    Franco, José G.; Franco, Suely S.H.; Villavicencio, Anna L.C., E-mail: zegilmar60@gmail.com, E-mail: gilmita@uol.com.br, E-mail: villavic@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil); Arthur, Valter; Arthur, Paula B., E-mail: arthur@cena.usp.br [Centro de Energia Nuclear na Agricultura (CENA/USP), Piracicaba, SP (Brazil); Franco, Caio H. [Universidade Federal de São Paulo (UNIFESP), SP (Brazil). Departamento de Microbiologia, Imunologia e Parasitologia

    2017-07-01

    The degree of radiosensitivity depends mostly on the species, the stage of the embryo at irradiation, the doses employed and the criteria used to measure the effect. One of the most common criteria to evaluate radiosensitivity in seeds is to measure the average plant production. Dry soya seeds were exposed to low doses of gamma radiation from source of Cobalt-60, type Gammecell-220, at 0.210 kGy dose rate. In order to study stimulation effects of radiation on germination, plant growth and production. A treatment with four radiation doses was applied as follows: 0 (control); 12.5; 25.0 and 50.0 Gy. Seed germination and harvested of number of seeds and total production were assessed to identify occurrence of stimulation. Soya seeds number and plants were handled as for usual seed production in Brazil. The low doses of gamma radiation in the seeds that stimulate the production were the doses of 12.5 and 50.0 Gy. The results show that the use of low doses of gamma radiation can stimulate germination and plant production. (author)

  19. Increase in. gamma. -radiation from powdered milk and beef

    Energy Technology Data Exchange (ETDEWEB)

    Sievert, R M; Gustafsson, S; Sylander, C G

    1956-01-01

    Samples of powdered milk and beef preserved during the years 1953 to 1956 were examined for the presence of ..gamma..-radiation. The higher ..gamma..-radiation found in the last year was attributed to an increase in fission products. Data are compared with measurements on a series of children.

  20. Radiation Calibration Measurements

    International Nuclear Information System (INIS)

    Omondi, C.

    2017-01-01

    KEBS Radiation Dosimetry mandate are: Custodian of Kenya Standards on Ionizing radiation, Ensure traceability to International System (SI ) and Calibration radiation equipment. RAF 8/040 on Radioisotope applications for troubleshooting and optimizing industrial process established Radiotracer Laboratory objective is to introduce and implement radiotracer technique for problem solving of industrial challenges. Gamma ray scanning technique applied is to Locate blockages, Locate liquid in vapor lines, Locate areas of lost refractory or lining in a pipe and Measure flowing densities. Equipment used for diagnostic and radiation protection must be calibrated to ensure Accuracy and Traceability

  1. Use of TL dosemeters for measuring doses of external gamma radiation in the vicinity of the Dukovany NPP

    International Nuclear Information System (INIS)

    Ohera, M.; Fiala, E.; Valasek, J.

    1992-01-01

    The results of measurement of the photon dose equivalent from external gamma radiation in the surroundings of the Dukovany nuclear power plant are given for 20 sites in southern Moravia over the 1984-1990 period, i.e., one year before starting up the plant and 6 years of its operation. CaSO 4 :Dy TL dosemeters were used, applying filtration with 0.5 mm Pb and 0.2 mm Pb + 0.6 mm Sn. Since 1989, the towns along the borders with Austria (Znojmo, Vranov, Mikulov) have been included, along with the Brno, Trebic, Zakrany, Ivancice and Jaromerice sites, into the national monitoring TL dosimetric network. The elevated doses at some sites come from the bedrock and are not caused by the operation of the plant. The effect of the Chernobyl accident on the dosemeter response is also evaluated. Comparison of the data prior to the Dukovany plant start-up (1984) and during the operation (1985-1990) give evidence that the operation of the power plant did not bring about any increase in the values monitored. (Z.S.). 3 tabs., 8 figs., 9 refs

  2. Sewage sterilization through gamma radiation

    International Nuclear Information System (INIS)

    Vieira, D.V.; Teixeira, W.M.S.; Silva, F.C.A. da

    2017-01-01

    Lack of sewage treatment and adequate sanitation conditions can contribute to the proliferation of numerous parasitic and infectious diseases in addition to water degradation. Approximately fifty types of infections can be transmitted from a sick to a healthy person through different pathways involving human excreta. Untreated sewage can contaminate water, food, hands, soil, etc. Epidemics of certain diseases such as typhoid, cholera, dysenteries, etc., and countless cases of worms are responsible for high mortality rates in third world countries. In the work the different techniques of sewage treatment by disinfestation and sterilization were analyzed, highlighting the use and the advantages of the gamma radiation as well as the aspects of the radiological protection involved. The technique of sewage sterilization using gamma radiation is a method of controlling bacteria and microorganisms. It is estimated that more than 200 large irradiators are in operation worldwide, of which 5 are in Brazil, for general sterilization use. These facilities use a large amount of radioactive material, in the order of millions of Becquerel, for sterilization with high doses of radiation, which can generate lethal doses in a few minutes. These industrial facilities use Cobalt-60, being classified by the International Atomic Energy Agency - IAEA as Category 1 of high risk, and must possess a high level of radiological protection to carry out the sterilization, standing out the defense in depth. Specific legislation on radiological protection should be drafted for safe work and avoid future radiation accidents

  3. Measurements of integrated components' parameters versus irradiation doses gamma radiation (60Co) dosimetry-methodology-tests

    International Nuclear Information System (INIS)

    Fuan, J.

    1991-01-01

    This paper describes the methodology used for the irradiation of the integrated components and the measurements of their parameters, using Quality Insurance of dosimetry: - Measurement of the integrated dose using the competences of the Laboratoire Central des Industries Electriques (LCIE): - Measurement of irradiation dose versus source/component distance, using a calibrated equipment. - Use of ALANINE dosimeters, placed on the support of the irradiated components. - Assembly and polarization of components during the irradiations. Selection of the irradiator. - Measurement of the irradiated components's parameters, using the competences of the societies: - GenRad: GR130 tests equipement placed in the DEIN/SIR-CEN SACLAY. - Laboratoire Central des Industries Electriques (LCIE): GR125 tests equipment and this associated programmes test [fr

  4. Mobile equipment for measurement of gamma radiation; Mobilt maaleutstyr for maaling av gammastraaling

    Energy Technology Data Exchange (ETDEWEB)

    2009-07-01

    NRPA has several systems to perform mobile measurements. One of the systems consists of detectors mounted on the roof of a car. Mobile systems can be used to map the radioactive contamination of large areas in a short time, to the reference measurements and to search for sources astray. The systems can be mounted on the vehicle or used in a helicopter or airplane. (AG)

  5. Measurement and assessment of mixed neutron-gamma radiation fields around the reconstructed HWRR

    International Nuclear Information System (INIS)

    Chen Changmao; Xie Jianlun; Chun Yuqing; Lin Nairong; Liu Jinhua; Su Jingling; Wei Zemin

    1987-01-01

    The neutron spectra around the HWRR (Heavy Water Research Reactor) of the Institute of Atomic Energy of China were measured. For the neutron spectra at different measuring points, the mean neutron energies ranged from 11 to 201 keV, the maximum energies were below 5 MeV, the effective quality factors were between 2.5 and 5, and the fast neutron dose equivalents mostly contributed the large fraction. During normal operation of the reactor, the n-γ dose equivalent rates in working areas were measured as well. In the experimental hall and the basement of the reactor, the mean values of the n/γ dose equivalent ratios were 15% and 31%, respectively; the γ dose equivalents were predominant. The annual dose equivalents to the persons working in the areas mentioned above possibly exceed the dose equivalent limit

  6. Galactic structure and gamma radiation

    International Nuclear Information System (INIS)

    Casse, Michel; Cesarsky, Catherine; Paul Jacques

    1977-01-01

    A model of spiral structure of the Galaxy is outlined from radiosynchrotron and gamma observations. The most interesting observations in the galactic context, obtained by the SAS II American satellite are concerned with the distribution of the γ photoemission at energies higher than 10 8 eV, along the galactic equator. The model proposed is in quantitative agreement with the present ideas on the spiral structure of the Galaxy, the galactic magnetic field, and the confinement of cosmic rays by the magnetic field and of the magnetic field by matter. Following the American era, the European COS-B satellite opens the European phase towards an identification of the discrete gamma radiation sources [fr

  7. Measurement of Gamma-ray Energy Spectrum According to Temperature Variation Using a Fiber-Optic Radiation Sensor Based on YSO:Ce Crystal

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, H.; Yoo, W. J.; Shin, S. H.; Jang, J. S.; Kim, J. S.; Kwon, G.; Lee, D. E.; Jang, K. W.; Lee, B. [BK21 Plus Research Institute of Biomedical Engineering, Konkuk University, Chungju (Korea, Republic of)

    2015-05-15

    As an alternative to conventional radiation detectors, various fiber-optic radiation sensors (FORSs) have been investigated for gamma-ray monitoring because of their various desirable advantages, such as their small sensing volume, substantial flexibility, remote operation, ability to make real-time measurement, and immunity to high electromagnetic interference. In general, the basic principle of a radiation detection using scintillators is to measure the scintillating light signals generated from the interactions between the scintillators and the radiations. To measure gamma-ray, the inorganic scintillators used in the FORS should have some properties, such as high atomic material, high light yields, fast decay time, high density, and high stopping power. For these reasons, a cerium-doped lutetium yttrium orthosilicate (LYSO:Ce) crystal has been introduced as a promising scintillator in various radiation sensor applications. According to the recent studies, however, LYSO:Ce crystal is impossible to be applied in high-temperature conditions because it serves the fluctuations of its light yields with the temperature variation (i.e., thermosluminescence). In this study, to obtain gamma-ray energy spectra by measuring scintillating light signals emitted from the scintillators in high-temperature conditions, we first fabricated an FORS system using various inorganic scintillator crystals and then evaluated the light yields of each inorganic scintillator. As a promising scintillator for use in high-temperature conditions, a cerium-doped yttrium orthosilicate (YSO:Ce) crystal was selected and evaluated its thermal property according to the elevated temperature up to 300 .deg. C. We fabricated an FORS using inorganic scintillator and an optical fiber bundle. To select an adequate scintillator to apply in high-temperature conditions, the gamma-ray energy spectra were obtained by using four kinds of inorganic scintillators. From the experimental results, we selected YSO

  8. Precise measurement of {gamma}(K{yields}e {nu}({gamma}))/{gamma}(K{yields}{mu} {nu}({gamma})) and study of K{yields}e {nu} {gamma}

    Energy Technology Data Exchange (ETDEWEB)

    Ambrosino, F.; Massarotti, P.; Meola, S.; Napolitano, M. [Dipartimento di Scienze Fisiche dell' Universita ' ' Federico II' ' , Napoli (Italy); INFN Sezione di Napoli, Napoli (Italy); Antonelli, A.; Antonelli, M.; Bencivenni, G.; Bloise, C.; Bossi, F.; Capon, G.; Capussela, T.; Ciambrone, P.; De Lucia, E.; De Simone, P.; Dreucci, M.; Felici, G.; Gatti, C.; Giovannella, S.; Jacewicz, M.; Lanfranchi, G.; Miscetti, S.; Moulson, M.; Murtas, F.; Palutan, M.; Santangelo, P.; Sciascia, B.; Sibidanov, A.; Spadaro, T.; Venanzoni, G. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Archilli, F. [Dipartimento di Fisica dell' Universita ' ' Tor Vergata' ' , Rome (Italy); INFN Sezione di Roma Tor Vergata, Rome (Italy); Beltrame, P.; Denig, A.; Mueller, S. [Johannes Gutenberg-Universitaet, Institut fuer Kernphysik, Mainz (Germany); Bini, C.; De Santis, A.; De Zorzi, G.; Di Domenico, A.; Fiore, S.; Franzini, P.; Gauzzi, P. [Dipartimento di Fisica dell' Universita ' ' La Sapienza' ' , Rome (Italy); INFN Sezione di Roma, Rome (Italy); Bocchetta, S.; Ceradini, F.; Di Micco, B.; Nguyen, F. [Dipartimento di Fisica dell' Universita ' ' Roma Tre' ' , Rome (Italy); INFN Sezione di Roma Tre, Rome (Italy); Branchini, P.; Graziani, E.; Passeri, A.; Tortora, L. [INFN Sezione di Roma Tre, Rome (Italy); Capriotti, D. [Dipartimento di Fisica dell' Universita ' ' Roma Tre' ' , Rome (Italy); Di Donato, C. [INFN Sezione di Napoli, Napoli (Italy); Kulikov, V. [Institute for Theoretical and Experimental Physics, Moscow (Russian Federation); Lee-Franzini, J. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); State University of New York, Physics Department, Stony Brook (United States); Martini, M.; Patera, V.; Versaci, R. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Dipartimento di Energetica dell' Universita ' ' La Sapienza' ' , Rome (Italy); Valente, P. [INFN Sezione di Roma, Rome (Italy)

    2009-12-15

    We present a precise measurement of the ratio R{sub K}={gamma}(K{yields}e{nu}({gamma}))/{gamma}(K{yields}{mu}{nu}({gamma})) and a study of the radiative process K{yields}e{nu}{gamma}, performed with the KLOE detector. The results are based on data collected at the Frascati e{sup +}e{sup -} collider DA {phi}NE for an integrated luminosity of 2.2 fb{sup -1}. We find R{sub K}=(2.493{+-}0.025{sub stat}{+-}0.019{sub syst}) x 10{sup -5}, in agreement with the Standard Model expectation. This result is used to improve constraints on parameters of the Minimal Supersymmetric Standard Model with lepton flavor violation. We also measured the differential decay rate d {gamma}(K{yields}e{nu}{gamma})/dE{sub {gamma}} for photon energies 10gamma}}<250 MeV. Results are compared with predictions from theory. (orig.)

  9. Gamma radiation effects on peanut skin antioxidants

    Energy Technology Data Exchange (ETDEWEB)

    Camargo, Adriano Costa de [Centro de Energia Nuclear na Agricultura (CENA/USP), Piracicaba, SP (Brazil); Canniatti-Brazaca, Solange Guidolin; Vieira, Thais Maria Ferreira de Souza; Regitano-d' Arce, Marisa Aparecida Bismara; Calori-Domingues, Maria Antonia, E-mail: sgcbraza@usp.b, E-mail: tvieira@esalq.usp.b, E-mail: mabra@esalq.usp.b, E-mail: macdomin@esalq.usp.b [Escola Superior de Agricultura Luiz de Queiroz (ESALQ/USP), Piracicaba, SP (Brazil). Dept. de Agroindustria, Alimentos e Nutricao

    2011-07-01

    Peanut skin, which is removed in the peanut blanching process, is rich in bioactive compounds with antioxidant properties. The viability of using natural sources of antioxidants to replace synthetic antioxidants was assessed. The aims of this study were to measure bioactive compounds in peanut skins and evaluate the effect of gamma radiation on their antioxidant activity. Peanut skin samples were treated with 0.0, 5.0, 7.5, or 10.0 kGy gamma rays at a dose rate of 7.5 kGy/h using a {sup 60}Co source. Total phenolics, condensed tannins, total flavonoids, and antioxidant activity were evaluated. Extracts obtained from the peanut skins were added to refined-bleached deodorized (RBD) soybean oil that was free from synthetic antioxidants. The oxidative stability of the oil samples was determined using the Rancimat method and compared to a control and synthetic antioxidants (100 mg/kg BHT and 200 mg/kg TBHQ). Gamma radiation changed total phenolic content, total condensed tannins, total flavonoid content, and the antioxidant activity. Ethanolic extracts, gamma irradiated or not, presented increasing induction period (h), measured by the Rancimat method, when compared with the control. Antioxidant activity of the peanut skins was higher than BHT but lower than THBQ. The present study confirmed that gamma radiation did not affect the peanut skin extracts' antioxidative level when added to soybean oil. The induction period of the control soybean oil was 5.7 h, while soybean oil with added ethanolic peanut skin extract had an induction period of 7.2 h, on average. (author)

  10. Gamma radiation effects on peanut skin antioxidants

    International Nuclear Information System (INIS)

    Camargo, Adriano Costa de; Canniatti-Brazaca, Solange Guidolin; Vieira, Thais Maria Ferreira de Souza; Regitano-d'Arce, Marisa Aparecida Bismara; Calori-Domingues, Maria Antonia

    2011-01-01

    Peanut skin, which is removed in the peanut blanching process, is rich in bioactive compounds with antioxidant properties. The viability of using natural sources of antioxidants to replace synthetic antioxidants was assessed. The aims of this study were to measure bioactive compounds in peanut skins and evaluate the effect of gamma radiation on their antioxidant activity. Peanut skin samples were treated with 0.0, 5.0, 7.5, or 10.0 kGy gamma rays at a dose rate of 7.5 kGy/h using a 60 Co source. Total phenolics, condensed tannins, total flavonoids, and antioxidant activity were evaluated. Extracts obtained from the peanut skins were added to refined-bleached deodorized (RBD) soybean oil that was free from synthetic antioxidants. The oxidative stability of the oil samples was determined using the Rancimat method and compared to a control and synthetic antioxidants (100 mg/kg BHT and 200 mg/kg TBHQ). Gamma radiation changed total phenolic content, total condensed tannins, total flavonoid content, and the antioxidant activity. Ethanolic extracts, gamma irradiated or not, presented increasing induction period (h), measured by the Rancimat method, when compared with the control. Antioxidant activity of the peanut skins was higher than BHT but lower than THBQ. The present study confirmed that gamma radiation did not affect the peanut skin extracts' antioxidative level when added to soybean oil. The induction period of the control soybean oil was 5.7 h, while soybean oil with added ethanolic peanut skin extract had an induction period of 7.2 h, on average. (author)

  11. Investigation of zones with increased ground surface gamma radiation

    International Nuclear Information System (INIS)

    Butkus, D.V.; Morkunas, G.S.; Styro, B.I.

    1989-01-01

    Measurements of the increased gamma radiation zones of soils were conducted in the South-Western part of the Litvinian. The shores of lakes in the north-eastern part of the Suduva high land were investigated. the maximum values of the gamma radiation dose rates were distributed along the lake shores at a distance of 1 m from the water surface, while farther than 1.5 m from it the dose rate was close to the natural value. The increased gamma radiation intensity zones on the ground surface were found only at the northern (Lake Reketija) or the western shore (other lakes under investigation). The highest values of the gamma radiation dose 200-600 μR/h (0.5-1.5 nGy/s) were observed in the comparatively small areas (up to several square metres). The gamma radiation intensity of soil surface increased strongly moving towards the point where the maximum intensity was obsered. 10 figs

  12. Characteristics of prepared gamma-ray calibration sources for radioactivity measurement of environmental and radiation control samples

    International Nuclear Information System (INIS)

    Samat, S.B.; Oi, Yoshihiro; Taki, Mitsumasa; Manabe, Iwao; Yoshida, Makoto; Minami, Kentaro

    1995-03-01

    Several types of calibration source having different density were prepared using one or combinations of those materials, namely foam cement, liquid, glass beads, polystyrene foam bead and hard plastic bead for gamma-ray spectrometry of the samples with different densities and shapes(variable height with constant base area). For each type of the source, a few sources were prepared to examine characteristics in such cases as (a) different heights but constant density, and (b) constant height and constant density. For the foam cement source, several sources with different densities and a constant height were prepared. All the sources were measured with a gamma-ray spectrometry system and the results were discussed. This report also presents the results obtained from the experiments for the evaluation of (1) the variation of detector efficiency-energy with gamma-ray energy, and (2) the variation of detector efficiency with density of the sources. (author)

  13. First measurement of the rate for the inclusive radiative penguin decay {ital b}{r_arrow}{ital s}{gamma}

    Energy Technology Data Exchange (ETDEWEB)

    Alam, M.S.; Kim, I.J.; Ling, Z.; Mahmood, A.H.; O`Neill, J.J.; Severini, H.; Sun, C.R.; Wappler, F.; Crawford, G.; Daubenmier, C.M.; Fulton, R.; Fujino, D.; Gan, K.K.; Honscheid, K.; Kagan, H.; Kass, R.; Lee, J.; Sung, M.; White, C.; Wolf, A.; Zoeller, M.M.; Butler, F.; Fu, X.; Nemati, B.; Ross, W.R.; Skubic, P.; Wood, M.; Bishai, M.; Fast, J.; Gerndt, E.; Hinson, J.W.; McIlwain, R.L.; Miao, T.; Miller, D.H.; Modesitt, M.; Payne, D.; Shibata, E.I.; Shipsey, I.P.J.; Wang, P.N.; Battle, M.; Ernst, J.; Gibbons, L.; Kwon, Y.; Roberts, S.; Thorndike, E.H.; Wang, C.H.; Coan, T.; Dominick, J.; Fadeyev, V.; Korolkov, I.; Lambrecht, M.; Sanghera, S.; Shelkov, V.; Skwarnicki, T.; Stroynowski, R.; Volobouev, I.; Wei, G.; Artuso, M.; Gao, M.; Goldberg, M.; He, D.; Horwitz, N.; Moneti, G.C.; Mountain, R.; Muheim, F.; Mukhin, Y.; Playfer, S.; Rozen, Y.; Stone, S.; Xing, X.; Zhu, G.; Bartelt, J.; Csorna, S.E.; Egyed, Z.; Jain, V.; Gibaut, D.; Kinoshita, K.; Pomianowski, P.; Barish, B.; Chadha, M.; Chan, S.; Cowen, D.F.; Eigen, G.; Miller, J.S.; O`Grady, C.; Urheim, J.; Weinstein, A.J.; Athanas, M.; Brower, W.; Masek, G.; Paar, H.P.; Gronberg, J.; Korte, C.M.; Kutschke, R.; Menary, S.; Morrison, R.J.; Nakanishi, S.; Nelson, H.N.; Nelson, T.K.; Qiao, C.; Richman, J.D.; Ryd, A.; Sperka, D.; Tajima, H.; Witherell, M.S.; Balest, R.; Cho, K.; Ford, W.T.; Johnson, D.R.; Lingel, K.; Lohner, M.; Rankin, P.; Smith, J.G.; Alexander, J.P.; Bebek, C.; Berkelman, K.; Bloom, K.; Browder, T.E.; Cassel, D.G.; Cho, H.A.; Coffman, D.M.; Crowcroft, D.S.; Drell, P.S.; Dumas, D.J.; Ehrlich, R.; Gaidarev, P.; Garcia-Sciveres, M.; Geiser, B.; Gittelman, B.; Gray, S.W.; Hartill, D.L.; Heltsley, B.K.; Henderson, S.; Jones, C.D.; Jones, S.L.; Kandaswamy, J.; Katayama, N.; Kim, P.C.; Kreinick, D.L.; Ludwig, G.S.; Masui, J.; Mevissen, J.; Mistry, N.B.; Ng, C.R.; Nordberg, E.; Patterson, J.R.; Peterson, D.; Riley, D.; Salman, S.; Sapper, M.; Wuerthwein, F.; Avery, P.; Freyberger, A.; Rodriguez, J.; (CLEO Co...

    1995-04-10

    We have measured the inclusive {ital b}{r_arrow}{ital s}{gamma} branching ratio to be (2.32{plus_minus}0.57{plus_minus}0.35){times}10{sup {minus}4}, where the first error is statistical and the second is systematic. Upper and lower limits on the branching ratio, each at 95% C.L., are {ital B}({ital b}{r_arrow}{ital s}{gamma}){lt}4.2{times}10{sup {minus}4} and {ital B}({ital b}{r_arrow}{ital s}{gamma}){gt}1.0{times}10{sup {minus}4}. These limits restrict the parameters of extensions of the standard model.

  14. Environmental gamma radiation monitoring at Visakhapatnam using thermoluminescence dosimeters

    International Nuclear Information System (INIS)

    Swarnkar, M.; Sahu, S.K.; Takale, R.A.; Shetty, P.G.; Pundit, G.G.; Puranik, V.D.

    2012-01-01

    The gamma rays are the most significant part of environmental dose due to its large range and deep penetrating power. The environmental gamma radiation is mainly originated from two sources natural radiation and artificially produced radiation. The natural radiation dose arises from the cosmic radiation (galactic and solar) and from the Earth (terrestrial) surface. In the last few decades there is a growing concern all over the world about radiation and their exposure to population. Thus it is necessary to conduct radiological environmental surveillance. The radiation survey data are useful to establish the natural background gamma radiation levels. Extensive gamma radiation survey was carried out around the surroundings of Vishakhapatnam using Thermoluminescence Dosimeters (TLDs). The CaSO 4 :(0.2 mole %) Dy Teflon TLD discs, specifically designed for environmental gamma radiation monitoring purpose were used. These TLD badge are having very high TL sensitivity, a negligible fading rate and a stable TL response. TLDs were deployed on quarterly basis for two years to obtain the cumulative gamma background radiation levels in the study area. The radiological survey was also carried out by using a calibrated radiation survey meter. The annual dose rates were computed from quarterly values actually found and normalised to 365 days. The environmental gamma radiation levels around Vishakhapatnam were found to be in the range of 0.79 mGy/y to 1.86 mGy/y. It is clearly seen from the results that location to location there is a large variation in external gamma radiation levels. During the cycle of the TLD survey, spot readings of the background radiation levels were taken, both while placing the TLDs and while removing them. The instantaneous dose rates measured using survey meter, are also following the large variation as found in TLDs. It varies between 110 nGy/hr to 210 nGy/hr. (author)

  15. Well logging with natural gamma radiation

    International Nuclear Information System (INIS)

    Ellis, D.V.

    1983-01-01

    An invention is described for use in natural gamma radiation well logging in which measurements taken in a borehole are used in the search for valuable underground resources such as oil or gas. The invention comprises deriving a log of natural gamma radiation detected in selected energy windows for a selected borehole depth interval and converting it into a log of the selected subsurface materials, e.g. Th, U, K. This log is corrected for the effects of 1) either a gamma ray emitter in the borehole fluid, e.g. potassium salts and/or 2) a gamma ray attenuator in the borehole fluid, e.g. a strong attenuator such as barite and/or hematite. The Th, U, K log is particularly useful in the exploration of oil and gas resources since the Th, U, K concentrations are a good indication as to the presence, type and volume of shale and clay in the formations surrounding the borehole. (U.K.)

  16. Gamma Radiation Doses In Sweden

    International Nuclear Information System (INIS)

    Almgren, Sara; Isaksson, Mats; Barregaard, Lars

    2008-01-01

    Gamma dose rate measurements were performed in one urban and one rural area using thermoluminescence dosimeters (TLD) worn by 46 participants and placed in their dwellings. The personal effective dose rates were 0.096±0.019(1 SD) and 0.092±0.016(1 SD)μSv/h in the urban and rural area, respectively. The corresponding dose rates in the dwellings were 0.11±0.042(1 SD) and 0.091±0.026(1 SD)μSv/h. However, the differences between the areas were not significant. The values were higher in buildings made of concrete than of wood and higher in apartments than in detached houses. Also, 222 Rn measurements were performed in each dwelling, which showed no correlation with the gamma dose rates in the dwellings

  17. Gamma radiation in ceramic capacitors: a study for space missions

    Science.gov (United States)

    dos Santos Ferreira, Eduardo; Sarango Souza, Juliana

    2017-10-01

    We studied the real time effects of the gamma radiation in ceramic capacitors, in order to evaluate the effects of cosmic radiation on these devices. Space missions have electronic circuits with various types of devices, many studies have been done on semiconductor devices exposed to gamma radiation, but almost no studies for passive components, in particular ceramic capacitors. Commercially sold ceramic capacitors were exposed to gamma radiation, and the capacitance was measured before and after exposure. The results clearly show that the capacitance decreases with exposure to gamma radiation. We confirmed this observation in a real time capacitance measurement, obtained using a data logging system developed by us using the open source Arduino platform.

  18. Virtual Gamma Ray Radiation Sources through Neutron Radiative Capture

    Energy Technology Data Exchange (ETDEWEB)

    Scott Wilde, Raymond Keegan

    2008-07-01

    The countrate response of a gamma spectrometry system from a neutron radiation source behind a plane of moderating material doped with a nuclide of a large radiative neutron capture cross-section exhibits a countrate response analogous to a gamma radiation source at the same position from the detector. Using a planar, surface area of the neutron moderating material exposed to the neutron radiation produces a larger area under the prompt gamma ray peak in the detector than a smaller area of dimensions relative to the active volume of the gamma detection system.

  19. Measurement of radiocesium concentration in trees using cumulative gamma radiation dose rate detection systems - A simple presumption for radiocesium concentration in living woods using glass-badge based gamma radiation dose rate detection system

    Energy Technology Data Exchange (ETDEWEB)

    Yoshihara, T.; Hashida, S.N. [Plant Molecular Biology, Laboratory of Environmental Science, Central Research Institute of Electric Power Industry (CRIEPI), 1646 Abiko, Chiba 270-1194 (Japan); Kawachi, N.; Suzui, N.; Yin, Y.G.; Fujimaki, S. [Radiotracer Imaging Gr., Quantum Beam Science Center, Japan Atomic Energy Agency (JAEA), 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan); Nagao, Y.; Yamaguchi, M. [Takasaki Advanced Radiation Research Institute, Japan Atomic Energy Agency (JAEA), 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan)

    2014-07-01

    Radiocesium from the severe accident at the Fukushima Dai-ichi Nuclear Power Plant on 11 March 2011 contaminates large areas. After this, a doubt for forest products, especially of mushroom, is indelible at the areas. Pruned woody parts and litters are containing a considerable amount of radiocesium, and generates a problem at incineration and composting. These mean that more attentive survey for each subject is expected; however, the present survey system is highly laborious/expensive and/or non-effective for this purpose. On the other hand, we can see a glass-badge based gamma radiation dose rate detection system. This system always utilized to detect a personal cumulative radiation dose, and thus, it is not suitable to separate a radiation from a specific object. However, if we can separate a radiation from a specific object and relate it with the own radiocesium concentration, it would enable us to presume the specific concentration with just an easy monitoring but without a destruction of the target nature and a complicated process including sampling, pre-treatment, and detection. Here, we present the concept of the measurement and results of the trials. First, we set glass-badges (type FS, Chiyoda Technol Corp., Japan) on a part of bough (approximately 10 cm in diameter) of Japanese flowering cherry trees (Prunus x yedoensis cv. Somei-Yoshino) with four different settings: A, a direct setting without any shield; B, a setting with an aluminum shield between bough and the glass-badge; C, a setting with a lead shield between bough and the glass-badge; D, a setting with a lead shield covering the glass-badge to shut the radiation from the surrounding but from bough. The deduction between the amount of each setting should separate a specific radiation of the bough from unlimited radiation from the surrounding. Even if the hourly dose rate is not enough to count the difference, a moderate cumulative dose would clear the difference. In fact, results demonstrated a

  20. In vivo measurement by thermoluminescence of the gamma ray radiation dose to the uterus delivered during 131I therapy of Basedow's disease

    International Nuclear Information System (INIS)

    Philippon, B.; Briere, J.

    1977-01-01

    131 I is often the therapy of choice for BASEDOW's disease. The determination of radiation dose to the gonads from a therapeutic dose of 131 I is therefore of importance and the accuracy of radiation dose calculation is uncertain because of the numerous biological variables involved. The dose to the uterus was directly measured in 20 volonteers with Basedow's disease using a thermoluminescent dosimeter of lithium fluoride and calcium dysprosium sulfate, attached to a copper intrauterine contraceptive device. The dosimeters were inserted at the time of administration of 131 I and were retreived one month later. By this method, the dose to the uterus from gamma rays only was measured and a gamma ray dose equal to the dose to the uterus, was assumed to the ovaries. In vivo experimental results were compared with the values calculated using the specific absorbed fractions (PHI (r 2 - r 1 ) determined by SNYDER. In the calculations, the morphology of the patient, in particular the distance from thyroid to uterus was taken into account. The in vivo measurements have also been compared with direct in vivo measurements using phantoms. In vivo measurements indicate that the average dose to the uterus and ovaries is of the order of 1 rad per 10 mCi concentrated in the thyroid gland. These figures are below the generally accepted maximum admissible dose to the gonads of 10 rems [fr

  1. Cosmical sources of gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Kuchowicz, B [Warsaw Univ. (Poland)

    1974-01-01

    A brief historical outline of the X-ray and ..gamma..-ray astronomies is given first, then a summary of the recent status of X-ray astronomy follows. Further chapters include information on ..gamma..-ray sources in the solar system, in our Galaxy, and beyond it. In discussing linear gamma spectra attention is paid to the possibility of studying explosive nucleo-synthesis by observation of gamma lines from supernova remnants, etc. Questions of the isotropic gamma background are discussed at the end of the survey.

  2. Gamma radiation detectors for safeguards applications

    International Nuclear Information System (INIS)

    Carchon, R.; Moeslinger, M.; Bourva, L.; Bass, C.; Zendel, M.

    2007-01-01

    The IAEA uses extensively a variety of gamma radiation detectors to verify nuclear material. These detectors are part of standardized spectrometry systems: germanium detectors for High-Resolution Gamma Spectrometry (HRGS); Cadmium Zinc Telluride (CZT) detectors for Room Temperature Gamma Spectrometry (RTGS); and NaI(Tl) detectors for Low Resolution Gamma Spectrometry (LRGS). HRGS with high-purity Germanium (HpGe) detectors cooled by liquid nitrogen is widely used in nuclear safeguards to verify the isotopic composition of plutonium or uranium in non-irradiated material. Alternative cooling systems have been evaluated and electrically cooled HpGe detectors show a potential added value, especially for unattended measurements. The spectrometric performance of CZT detectors, their robustness and simplicity are key to the successful verification of irradiated materials. Further development, such as limiting the charge trapping effects in CZT to provide improved sensitivity and energy resolution are discussed. NaI(Tl) detectors have many applications-specifically in hand-held radioisotope identification devices (RID) which are used to detect the presence of radioactive material where a lower resolution is sufficient, as they benefit from a generally higher sensitivity. The Agency is also continuously involved in the review and evaluation of new and emerging technologies in the field of radiation detection such as: Peltier-cooled CdTe detectors; semiconductor detectors operating at room temperature such as HgI 2 and GaAs; and, scintillator detectors using glass fibres or LaBr 3 . A final conclusion, proposing recommendations for future action, is made

  3. Project Marna Natural Gamma Radiation MAP

    International Nuclear Information System (INIS)

    Suarez, E.; Fernandez, J.A.

    1997-01-01

    The confusion created by the accident that occurred in one of the Chernobyl reactors in April of 1986 made the general public and governments aware of the need for improved monitoring of environmental radiation levels. The levels of total gamma radiation or total gamma exposure rate over large areas reached values as high as 400 micro Roentgen/hour (mu R/h) and at points exceeded 1000 mu R/h. It should be borne in mind that, depending on the type of geological formations, normal values range from 5 to 30 mu R/h. The IAEA recommended to all countries that natural gamma radiation maps be made available to evaluate the levels of natural gamma radiation and possible increases, and it also indicated its concern that information be standardized. In addition, it stressed the advisability of using data obtained from uranium prospecting. (Author)

  4. Semiconductor scintillator detector for gamma radiation

    International Nuclear Information System (INIS)

    Laan, F.T.V. der; Borges, V.; Zabadal, J.R.S.

    2015-01-01

    Nowadays the devices employed to evaluate individual radiation exposition are based on dosimetric films and thermoluminescent crystals, whose measurements must be processed in specific transductors. Hence, these devices carry out indirect measurements. Although a new generation of detectors based on semiconductors which are employed in EPD's (Electronic Personal Dosemeters) being yet available, it high producing costs and large dimensions prevents the application in personal dosimetry. Recent research works reports the development of new detection devices based on photovoltaic PIN diodes, which were successfully employed for detecting and monitoring exposition to X rays. In this work, we step forward by coupling a 2mm anthracene scintillator NE1, which converts the high energy radiation in visible light, generating a Strong signal which allows dispensing the use of photomultipliers. A low gain high performance amplifier and a digital acquisition device are employed to measure instantaneous and cumulative doses for energies ranging from X rays to Gamma radiation up to 2 MeV. One of the most important features of the PIN diode relies in the fact that it can be employed as a detector for ionization radiation, since it requires a small energy amount for releasing electrons. Since the photodiode does not amplify the corresponding photon current, it must be coupled to a low gain amplifier. Therefore, the new sensor works as a scintillator coupled with a photodiode PIN. Preliminary experiments are being performed with this sensor, showing good results for a wide range of energy spectrum. (author)

  5. On the honeybee resistance to gamma radiation

    International Nuclear Information System (INIS)

    Courtois, G.; Lecomte, J.

    1960-01-01

    The honeybee, when irradiated by gamma radiations from a cobalt-60 source can stand a 18000 r dose without any apparent harm. Noticeable harm is observed for 90000 r. while immediate death of 100% of the individuals is obtained with a 200000 r dose. The physiological condition of the honeybee plays an important role in its resistance to gamma radiation. Reprint of a paper published in Annales de l'abeille, IV, 1959, p. 285-290 [fr

  6. Research progress in airborne surveys of terrestrial gamma radiation

    International Nuclear Information System (INIS)

    Burson, Z.G.

    1974-01-01

    Progress during the last few years in airborne surveys of terrestrial gamma radiation, i.e. in the measuring, recording, and interpreting of gamma ray signals in NaI(Tl) crystals, is discussed. Non-terrestrial background contributions have been accurately characterized. The feasibility of determining the water equivalent of snow cover by aerial survey techniques has been demonstrated. Repeat surveys over areas surrounding reactor sites can now be used to detect average differences of less than 1.0 μR/hr in terrestrial gamma radiation levels. New data acquisition and recording systems allow isotope concentrations and total inventories to be measured in spatial resolutions of a few hundred feet. Aerial survey data have been combined with population distribution data to obtain population exposure values from natural terrestrial gamma radiation around reactor sites

  7. Localization of the gamma-radiation sources using the gamma-visor

    Directory of Open Access Journals (Sweden)

    Ivanov Kirill E.

    2008-01-01

    Full Text Available The search of the main gamma-radiation sources at the site of the temporary storage of solid radioactive wastes was carried out. The relative absorbed dose rates were measured for some of the gamma-sources before and after the rehabilitation procedures. The effectiveness of the rehabilitation procedures in the years 2006-2007 was evaluated qualitatively and quantitatively. The decrease of radiation background at the site of the temporary storage of the solid radioactive wastes after the rehabilitation procedures allowed localizing the new gamma-source.

  8. Localization of the gamma-radiation sources using the gamma-visor

    International Nuclear Information System (INIS)

    Ivanov, K. E.; Ponomaryev-Stepnoi, N. N.; Stepennov, B. S.; Teterin, Y. A.; Teterin, A. Y.; Kharitonov, V. V.

    2008-01-01

    The search of the main gamma-radiation sources at the site of the temporary storage of solid radioactive wastes was carried out. The relative absorbed dose rates were measured for some of the gamma-sources before and after the rehabilitation procedures. The effectiveness of the rehabilitation procedures in the years 2006-2007 was evaluated qualitatively and quantitatively. The decrease of radiation background at the site of the temporary storage of the solid radioactive wastes after the rehabilitation procedures al lowed localizing the new gamma-source. (author)

  9. Effects of gamma radiation in tomato seeds

    Energy Technology Data Exchange (ETDEWEB)

    Wiendl, Toni A.; Wiendl, Fritz W.; Franco, Suely S.H.; Franco, Jose G.; Althur, Valter, E-mail: tawiendl@hotmail.com, E-mail: gilmita@uol.com.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Arthur, Paula B., E-mail: arthur@cena.usp.br [Centro de Energia Nuclear na Agricultura (CENA/USP), Piracicaba, SP (Brazil)

    2013-07-01

    Tomato dry seeds of the hybrid 'Gladiador' F1 were exposed to low doses of gamma radiation from Co-60 source at 0,509 kGy tax rate in order to study stimulation effects of radiation on germination and plant growth. Eight treatments radiation doses were applied as follows: 0 (control); 2,5; 5,0; 7,5; 10,0; 12,5; 15,0; 20,0 Gy. Seed germination as well as green fruits number, harvested fruit number, fruit weight and total production were assessed to identify occurrence of stimulation. Tomato seeds and plants were handled as for usual tomato production in Brazil. Low doses of gamma radiation treatment in the seeds stimulate germination and substantially increase fruit number and total production up to 86% at 10 Gy dose. There are evidences that the use of low doses of gamma radiation can stimulate germination and plant production thus, showing hormetic effects. (author)

  10. Effects of gamma radiation in tomato seeds

    International Nuclear Information System (INIS)

    Wiendl, Toni A.; Wiendl, Fritz W.; Franco, Suely S.H.; Franco, Jose G.; Althur, Valter; Arthur, Paula B.

    2013-01-01

    Tomato dry seeds of the hybrid 'Gladiador' F1 were exposed to low doses of gamma radiation from Co-60 source at 0,509 kGy tax rate in order to study stimulation effects of radiation on germination and plant growth. Eight treatments radiation doses were applied as follows: 0 (control); 2,5; 5,0; 7,5; 10,0; 12,5; 15,0; 20,0 Gy. Seed germination as well as green fruits number, harvested fruit number, fruit weight and total production were assessed to identify occurrence of stimulation. Tomato seeds and plants were handled as for usual tomato production in Brazil. Low doses of gamma radiation treatment in the seeds stimulate germination and substantially increase fruit number and total production up to 86% at 10 Gy dose. There are evidences that the use of low doses of gamma radiation can stimulate germination and plant production thus, showing hormetic effects. (author)

  11. Fluorescent L-radiation and the. gamma. -radiation of ionium

    Energy Technology Data Exchange (ETDEWEB)

    Riou, M

    1949-02-21

    Irene Curie, Compt. rend. 227, 1225(1948), has shown that the ..gamma..-radiation of ionium is accompanied by a soft radiation that can be identified with the fluorescent L-lines of radium. The present author submitted these radiations to a further study, using as a source a ionium--thorium mixture, (100 mg of hydrate), containing 9% ionium. The Geiger--Mueller counters had 5 mg/cm/sup 2/ aluminum ends and were filled with alcohol + xenon at 10-21 cm Hg. The absorption curves in Cu, Mo, and Ag showed that the energy of the soft radiation was about 14 keV. For the separation of lines, the selective absorption was determined in elements from Z = 28 to Z = 53. The results confirmed the attribution of the spectrum to the L-radiation of Ra. Similar measurements on radioactinium revealed the same lines with approximately the same intensities. In both cases a radium isotope is formed: /sub 90/Th/sup 230/(Io) ..-->.. /sub 88/Ra/sup 226/ ..-->.. ..cap alpha.., /sub 90/Th/sup 227/ (RaAc) ..-->.. /sub 88/Ra/sup 223/ (AcX) + ..cap alpha... The identity of the spectra shows that the atomic number of the formed atom alone determines the L-spectrum, and that in both cases the L level is excited as a result of an internal conversion of ..gamma..-lines: the line 68 keV in the case of ionium, eight lines 26-100 keV in that of radioactinium. On the basis of the intensities found, the relative numbers of photons corresponding to the levels L/sub I/, L/sub II/, and L/sub III/ could be calculated; they are L/sub I/:L/sub II/:L/sub III/ = 50:20:26. The ..gamma..-rays of ionium, as determined from the absorption in Cu, Ta, and Pb, are 68 and 200 kev. By assuming that the efficiency of the counters is equal to 1 - exp (-m..mu../rho), (where m is the efficient superficial mass of xenon, and ..mu../rho is the absorption coefficient in xenon), the intensities of the L- and ..gamma..-radiations of ionium can be given in terms of numbers of quanta per 100 disintegrations.

  12. Dose Rate of Environmental Gamma Radiation in Java Island

    International Nuclear Information System (INIS)

    Gatot Suhariyono; Buchori; Dadong Iskandar

    2007-01-01

    The dose rate Monitoring of environmental gamma radiation at some locations in Java Island in the year 2005 / 2006 has been carried out. The dose rate measurement of gamma radiation is carried out by using the peripheral of Portable Gamma of Ray Spectrometer with detector of NaI(Tl), Merck Exploranium, Model GR-130- MINISPEC, while to determine its geographic position is used by the GPS (Global Positioning System), made in German corporation of GPS III Plus type. The division of measurement region was conducted by dividing Java Island become 66 parts with same distance, except in Jepara area that will built PLTN (Nuclear Energy Power), distance between measurement points is more closed. The results of dose rate measurement are in 66 locations in Java Island the range of (19.24 ± 4.05) nSv/hour until (150.78 ± 12.26) nSv/hour with mean (51.93 ± 36.53) nSv/h. The lowest dose rate was in location of Garut, while highest dose rate was in Ujung Lemah Abang, Jepara location. The data can be used for base line data of dose rate of environmental gamma radiation in Indonesia, specially in Java Island. The mean level of gamma radiation in Java monitoring area (0.46 mSv / year) was still lower than worldwide average effective dose rate of terrestrial gamma rays 0.5 mSv / year (report of UNSCEAR, 2000). (author)

  13. SGR-76 gamma radiation level indicator

    International Nuclear Information System (INIS)

    Chubinskij-Nadezhdin, I.V.

    1978-01-01

    The design of a gamma-radiation level indicator is described; the instrument is part of a mobile radiometric laboratory (MRL). The design of the instrument permits gamma-radiation dose rates recording at 0.2-200 R/hr, and signals on gamma-background levels. The instrument has two separate threshold levels of signalling actuation. The light signalling at the first level is precautionary, and the sound signalling at the second level indicates the necessity of taking a decision as to whether or not the MRL can remain in the gamma-radiation field. Halogenic counters operating in a current mode are used as detectors. The basic error in recording the dose rate amounts to +-25%. Overall dimensions of the instrument 150x280x100 mm; weight less than 2.5 kg

  14. Radiation practices and radiation measurements

    International Nuclear Information System (INIS)

    2008-03-01

    The guide presents the principal requirements on accuracy of radiation measurements and on the approval, calibration and operating condition inspections of radiation meters, together with requirements for dosimetric services measuring the individual radiation doses of workers engaged in radiation work (approved dosimetric services). The Guide also sets out the definitions of quantities and units used in radiation measurements. The radiation protection quantities used for assessing the harmful effects of radiation and for expressing the maximum values for radiation exposure (equivalent dose and effective dose) are set out in Guide ST 7.2. This Guide concerns measurements of ionizing radiation involved in radiation practices, the results of which are used for determining the radiation exposure of workers engaged in radiation work and members of the public, and of patients subject to the use of radiation in health services, or upon the basis of which compliance with safety requirements of appliances currently in use and of their premises of use or of the workplaces of workers is ensured. The Guide also concerns measurements of the radon concentration of inhaled air in both workplaces and dwellings. The Guide does not apply to determining the radiation exposure of aircrews, determination of exposure caused by internal radiation, or measurements made to protect the public in the event of, or in preparation for abnormal radiation conditions

  15. Sterilization plants equipped with the isotopic gamma radiation sources

    International Nuclear Information System (INIS)

    Mehta, K.; Chmielewski, A.G.

    2007-01-01

    Presentation describes different isotopic gamma radiation sources applicable for sterilization of food and medical materials. Certain gamma pallet irradiators, mini gamma irradiators and different scale gamma tote irradiators are presented. It is concluded, that about two hundreds plants with gamma radiation sources operates in different countries. However, industrially developed countries must construct much more plants than operates now

  16. Environmental gamma radiation levels around various DAE research centres

    International Nuclear Information System (INIS)

    Takale, R.A.; Swarnakar, M.; Shetty, P.G.; Sahu, S.K.; Pandit, G.G.

    2014-01-01

    This paper presents the gamma radiation levels of four research centres viz. Bhabha Atomic Research Centre (BARC), Trombay; Indira Gandhi Centre for Atomic Research (IGCAR), Kalpakkam; Variable Energy Cyclotron Centre (VECC), Kolkata; Raja Ramanna Centre for Advanced Technology (RRCAT), Indore; and an industry Board of Radiation and Isotope Technology (BRIT), Vashi. BARC is India's premier nuclear research facility and is a multi-disciplinary research centre with extensive infrastructure for advanced research and development (R and D). IGCAR, Kalpakkam is engaged in scientific research and advanced engineering programme towards the development of Fast Breeder Reactor technology. VECC Kolkata is dedicated to carry out frontier R and D in the fields of Accelerator Science and Technology, Nuclear Science (Theoretical and Experimental), and Material Science etc. RRCAT, Indore has rapidly grown into a premier institute for R and D in lasers, accelerators and their applications. BRIT, Vashi unit is involved in production, development, and supply of radioisotope based products and provision of isotope applications, radiation processing, radio analytical services etc. With an objective to keep a watch on the prevailing environmental background gamma radiation level around all the DAE installations, routine monitoring programme are being carried out using the Thermo Luminescent Dosimeters (TLDs). TLDs provide the simple, inexpensive and precise measurement of small, integrated, external gamma radiation dose rate. The general practice of this programme is to observe the outdoor gamma radiation levels. This paper summarizes the methodology and gamma radiation levels of four research centres viz. BARC, IGCAR, VECC, RRCAT and an industry BRIT, Vashi

  17. Determination of the detection limit and decision threshold for ionizing radiation measurements. Part 3: Fundamentals and application to counting measurements by high resolution gamma spectrometry, without the influence of sample treatment

    International Nuclear Information System (INIS)

    2000-01-01

    This part of ISO 11929 addresses the field of ionizing radiation measurements in which events (in particular pulses) are counted by high resolution gamma spectrometry registrating a pulse-heights distribution (acquisition of a multichannel spectrum), for example on samples. It considers exclusively the random character of radioactive decay and of pulse counting and ignores all other influences (e.g. arising from sample treatment, weighing, enrichment or the instability of the test setup). It assumes that the distance of neighbouring peaks of gamma lines is not smaller than four times the full width half maximum (FWHM) of gamma line and that the background near to gamma line is nearly a straight line. Otherwise ISO 11929-1 or ISO 11929-2 should be used. ISO 11929 consists of the following parts, under the general title Determination of the detection limit and decision threshold for ionizing radiation measurements: Part 1: Fundamentals and application to counting measurements without the influence of sample treatment; Part 2: Fundamentals and application to counting measurements with the influence of sample treatment; Part 3: Fundamentals and application to counting measurements by high resolution gamma spectrometry, without the influence of sample treatment; Part 4: Fundamentals and application to measurements by use of linear scale analogue ratemeters, without the influence of sample treatment. This part of ISO 11929 was prepared in parallel with other International Standards prepared by WG2 (now WG 17): ISO 11932:1996, Activity measurements of solid materials considered for recycling, re-use or disposal as nonradioactive waste, and ISO 11929-1, ISO 11929-2 and ISO 11929-4, and is, consequently, complementary to these documents

  18. A new measurement of the rare decay eta -> pi^0 gamma gamma with the Crystal Ball/TAPS detectors at the Mainz Microtron

    Energy Technology Data Exchange (ETDEWEB)

    Nefkens, B M; Prakhov, S; Aguar-Bartolom��, P; Annand, J R; Arends, H J; Bantawa, K; Beck, R; Bekrenev, V; Bergh��user, H; Braghieri, A; Briscoe, W J; Brudvik, J; Cherepnya, S; Codling, R F; Collicott, C; Costanza, S; Danilkin, I V; Denig, A; Demissie, B; Dieterle, M; Downie, E J; Drexler, P; Fil' kov, L V; Fix, A; Garni, S; Glazier, D I; Gregor, R; Hamilton, D; Heid, E; Hornidge, D; Howdle, D; Jahn, O; Jude, T C; Kashevarov, V L; K��ser, A; Keshelashvili, I; Kondratiev, R; Korolija, M; Kotulla, M; Koulbardis, A; Kruglov, S; Krusche, B; Lisin, V; Livingston, K; MacGregor, I J; Maghrbi, Y; Mancel, J; Manley, D M; McNicoll, E F; Mekterovic, D; Metag, V; Mushkarenkov, A; Nikolaev, A; Novotny, R; Oberle, M; Ortega, H; Ostrick, M; Ott, P; Otte, P B; Oussena, B; Pedroni, P; Polonski, A; Robinson, J; Rosner, G; Rostomyan, T; Schumann, S; Sikora, M H; Starostin, A; Strakovsky, I I; Strub, T; Suarez, I M; Supek, I; Tarbert, C M; Thiel, M; Thomas, A; Unverzagt, M; Watts, D P; Werthmueller, D; Witthauer, L

    2014-08-01

    A new measurement of the rare, doubly radiative decay eta->pi^0 gamma gamma was conducted with the Crystal Ball and TAPS multiphoton spectrometers together with the photon tagging facility at the Mainz Microtron MAMI. New data on the dependence of the partial decay width, Gamma(eta->pi^0 gamma gamma), on the two-photon invariant mass squared, m^2(gamma gamma), as well as a new, more precise value for the decay width, Gamma(eta->pi^0 gamma gamma) = (0.33+/-0.03_tot) eV, are based on analysis of 1.2 x 10^3 eta->pi^0 gamma gamma decays from a total of 6 x 10^7 eta mesons produced in the gamma p -> eta p reaction. The present results for dGamma(eta->pi^0 gamma gamma)/dm^2(gamma gamma) are in good agreement with previous measurements and recent theoretical calculations for this dependence.

  19. Gamma response study of radiation sensitive MOSFETs for their use as gamma radiation sensor

    Energy Technology Data Exchange (ETDEWEB)

    Srivastava, Saurabh; Kumar, A. Vinod [Radiation Safety Systems Division, Bhabha Atomic Research Centre, Mumbai (India); Aggarwal, Bharti; Singh, Arvind; Topkar, Anita, E-mail: anita@barc.gov.in [Electronics Division, Bhabha Atomic Research Centre, Mumbai (India)

    2016-05-23

    Continuous monitoring of gamma dose is important in various fields like radiation therapy, space-related research, nuclear energy programs and high energy physics experiment facilities. The present work is focused on utilization of radiation-sensitive Metal-Oxide-Semiconductor Field Effect Transistors (MOSFETs) to monitor gamma radiation doses. Static characterization of these detectors was performed to check their expected current-voltage relationship. Threshold voltage and transconductance per unit gate to source voltage (K factor) were calculated from the experimental data. The detector was exposed to gamma radiation in both, with and without gate bias voltage conditions, and change in threshold voltage was monitored at different gamma doses. The experimental data was fitted to obtain equation for dependence of threshold voltage on gamma dose. More than ten times increase in sensitivity was observed in biased condition (+3 V) compared to the unbiased case.

  20. Gamma radiation effects on nestling Tree Swallows

    International Nuclear Information System (INIS)

    Zach, R.; Mayoh, K.R.

    1984-01-01

    The sensitivity of Tree Swallows (Tachycineta bicolor) to the stress of ionizing radiation was investigated with growth analysis. Freshly hatched nestlings were temporarily removed from nests, taken to the laboratory and acutely exposed to 0.9, 2.7, or 4.5 Gy gamma radiation. Some of the unirradiated control nestlings were also taken to the laboratory whereas others were left in the nests. Growth of all the nestlings was measured daily and analyzed by fitting growth models. There was no detectable radiation-induced mortality up to fledgling, approx. = 20 d after irradiation. Radiation exposure did not affect the basic growth pattern; the logistic growth model was most suitable for body mass and foot length, and the von Bertalanffy model for primary-feather length, irrespective of treatment. Parameter values from these models indicated pronounced growth depression in the 2.7-Gy and 4.5-Gy groups, particularly for body mass. Radiation also affected the timing of development. The growth depression of the 2.7-Gy group was similar to that caused by hatching asynchrony in unirradiated nestlings. The 4.5-Cy nestlings grew as well as unexposed nestlings that died from natural causes. Chronic irradiation at approx. = 1.0 Cy/d caused more severe growth effects than acute exposure to 4.5 Gy and may have caused permanent stunting. Growth analysis is a potent tool for assessing man-made environmental stresses. Observed body-mass statistics and model parameters seem to be most sensitive to environmental stresses, but coefficients of variation are not necessarily correlated with sensitivity. 34 references, 2 figures, 4 tables

  1. Sensitiveness of jasmine cuttings to gamma radiation

    International Nuclear Information System (INIS)

    Devaiah, K.A.; Srivastava, H.C.

    1989-01-01

    Half lethal dose (LD 50 ) gamma radiation for five genotypes of jasmine and the effect of such radiation on their rooting parameters were studied. The LD 50 was close to 2.5 krad for Jasminum grandiflorum var. Pink Pin, 0.5 krad for var. Pink Thrum, 2.5 krad for J. flexile Valh., 1 krad for J. calophyllum Wall and 2 krad for J. sambac Ait var. 'Gundumalli'. Percentage of rooting, number of roots per cutting, length and thickness of roots decreased with increase in intensity of gamma irradiation. (author) 8 refs.; 4 tabs

  2. Development of radiation safety monitoring system at gamma greenhouse gamma facility

    International Nuclear Information System (INIS)

    Hairul Nizam Idris; Azimawati Ahmad, Ahmad Zaki Hussain; Ahmad Fairuz Mohd Nasir

    2009-01-01

    This paper is discussing about installation of radiation safety monitoring system at Gamma Greenhouse Gamma facility, Agrotechnology and Bioscience Division (BAB). This facility actually is an outdoor type irradiation facility, which first in Nuclear Malaysia and the only one in Malaysia. Source Cs-137 (801 Curie) was use as radiation source and it located at the centre of 30 metres diameter size of open irradiation area. The radiation measurement and monitoring system to be equipped in this facility were required the proper equipment and devices, specially purpose for application at outside of building. Research review, literature study and discussion with the equipment manufacturers was being carried out, in effort to identify the best system should be developed. Factors such as tropical climate, environment surrounding and security were considered during selecting the proper system. Since this facility involving with panoramic radiation type, several critical and strategic locations have been fixed with radiation detectors, up to the distance at 200 meter from the radiation source. Apart from that, this developed system also was built for capable to provide the online real-time reading (using internet). In general, it can be summarized that the radiation safety monitoring system for outdoor type irradiation facility was found much different and complex compared to the system for indoor type facility. Keyword: radiation monitoring, radiation safety, Gamma Greenhouse, outdoor irradiation facility, panoramic radiation. (Author)

  3. Construction, calibration and test of an ionization chamber for exposure measurement of x and gamma radiation in region from 40 keV to 1250 keV

    International Nuclear Information System (INIS)

    Campos, C.A.A.L.

    1982-01-01

    An unsealed thimble ionization chamber with connecting cable was designed, manufactured and tested at the IRD=CNEN, for exposure or exposure rate measurement of X or gamma rays in the energy range from 40 KeV up to Cobalt-60. Recommendations given by IEC, TC-62 (1974) were used as acceptance tests of the ionization chamber for use as a tertiary standard (field class instruments) in radiation therapy. In addition, intercomparison with commercially available chambers of reference class type were carried out in respect to field size dependence, energy dependence, short and long term stability. The results of those tests indicated the usefulness of the developed ionization chamber as a tertiary standard. (author)

  4. Effects of gamma radiation in annatto seeds

    International Nuclear Information System (INIS)

    Franco, Camilo F. de Oliveira; Arthur, Valter; Arthur, Paula B.; Harder, Marcia N.C.; Filho, Jose C.; Neto, Miguel B.

    2015-01-01

    The annatto bixin has emerged as a major source of natural dyes used in the world notably by the substitution of synthetics harmful to human health and ecologic tendency in obtaining industrial products free of additives with applications in industries textiles; cosmetics; pharmaceutical and food mainly. The aim of this research was to obtain increased of germination rate and dormancy breaking on annatto seeds by gamma radiation. Annatto dry seeds were exposed to low doses of gamma radiation from source of Cobalt-60, type Gammecell-220, at 0.456 kGy/hour dose rate. In order to study stimulation effects of radiation on germination rate and dormancy breaking in the seeds. Five treatments with gamma radiation doses were applied as follows: 0 (control); 100; 125; 150 and 175 Gy. After irradiation the annatto seeds were planted as for usual seed production. According to the results obtained in this experiment we can conclude that the low doses of gamma radiation utilized on the annatto seeds did not presented significantly effect on the germination of plants. But the best dose to increase the germination of seeds was 150 Gy. (author)

  5. Effects of gamma radiation in annatto seeds

    Energy Technology Data Exchange (ETDEWEB)

    Franco, Camilo F. de Oliveira, E-mail: camilo.urucum@hotmail.com [Empresa Brasileira de Pesquisa Agropecuaria (EMBRAPA/EMEPA), Joao Pessoa, PB (Brazil); Arthur, Valter; Arthur, Paula B., E-mail: arthur@cena.usp.br [Centro de Energia Nuclear na Agricultura (CENA/USP), Piracicaba, SP (Brazil); Harder, Marcia N.C., E-mail: marcia.harder@fatec.sp.gov.br [Centro Paula Souza, Curso Superior de Tecnologia em Bicombustiveis (FATEC), Piracicaba, SP (Brazil); Filho, Jose C.; Neto, Miguel B., E-mail: jorgecazefilho@yahoo.com.br [Empresa Estadual de Pesquisa Agropecuaria da Paraiba (EMEPA), Joao Pessoa, PB (Brazil)

    2015-07-01

    The annatto bixin has emerged as a major source of natural dyes used in the world notably by the substitution of synthetics harmful to human health and ecologic tendency in obtaining industrial products free of additives with applications in industries textiles; cosmetics; pharmaceutical and food mainly. The aim of this research was to obtain increased of germination rate and dormancy breaking on annatto seeds by gamma radiation. Annatto dry seeds were exposed to low doses of gamma radiation from source of Cobalt-60, type Gammecell-220, at 0.456 kGy/hour dose rate. In order to study stimulation effects of radiation on germination rate and dormancy breaking in the seeds. Five treatments with gamma radiation doses were applied as follows: 0 (control); 100; 125; 150 and 175 Gy. After irradiation the annatto seeds were planted as for usual seed production. According to the results obtained in this experiment we can conclude that the low doses of gamma radiation utilized on the annatto seeds did not presented significantly effect on the germination of plants. But the best dose to increase the germination of seeds was 150 Gy. (author)

  6. The annual terrestrial gamma radiation dose to the population of the urban Christchurch area

    International Nuclear Information System (INIS)

    Chapman, R.H.

    1983-01-01

    Natural terrestrial gamma radiation dose rates were measured with a high pressure ionization chamber at 70 indoor (195 site measurements) and 58 outdoor locations in the metropolitan Christchurch area. Based on these site measurements, the average gonad dose rate to the population from natural terrestrial gamma radiation was estimated to be 273+-56 microgray per annum. (auth)

  7. Gamma, radon, natural radioactivity measurements in Chile

    International Nuclear Information System (INIS)

    Stuardo, E.

    1997-01-01

    Different natural radiation measurements, performed since 1983, are analysed and discussed regarding the average effective population dose. A decade of absorbed gamma dose measurements in air (1983-93), were carried out using compensated TLD detectors, during long periods of integration time and with a network of 11 stations, along the country, from Arica to the Antarctic territory. An indoor Rn -222 and gamma survey dwellings, in high background zones, underground mines and drinking water was started in 1988 using different kind of detectors, including electret radon chambers. The methods, dose assessments and results are presented and discussed in the frame of worldwide average effective population doses. None of the average effective doses found over the evaluated areas, exceed the comparison levels. (author)

  8. Residual water treatment for gamma radiation. Tratamiento de aguas residuales por radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Mendez, L [Universidad Nacional Mayor de San Marcos. Facultad de Quimica (Peru)

    1990-07-01

    The treatment of residual water by means of gamma radiation for its use in agricultural irrigation is evaluated. Measurements of physical, chemical, biological and microbiological contamination indicators were performed. For that, samples from the treatment center of residual water of San Juan de Miraflores were irradiated up to a 52.5 kGy dose. The study concludes that gamma radiation is effective to remove parasites and bacteria, but not for removal of the organic and inorganic matter. (author). 15 refs., 3 tabs., 4 figs.

  9. Gamma radiation utilization for polymers synthesis

    International Nuclear Information System (INIS)

    Santos, L.G. dos; Silva Filho, E.

    1990-01-01

    Samples of styrene monomer were irradiated with gamma rays from a sup(60)Co source, with doses in the range of zero to 32600 Gray (Gy). Viscosity analysis performed by using the method of Stokes showed an increase in the viscosity of the material. This result characterizes the occurrence of polymerization induced by the radiation. (author)

  10. Gamma radiation sterilization of Bactrocera invadens (Diptera ...

    African Journals Online (AJOL)

    The African invader fly, Bactrocera invadens, an invasive pest in Africa since 2003, causes damage and poses a threat to the mango and horticultural industry. Its control is therefore needed. Sterilization of males using gamma radiation doses (25, 50 and 75 Gy) as a means of population control was investigated. Irradiation ...

  11. Gamma and electron radiation effects on straw

    International Nuclear Information System (INIS)

    Leonhardt, J.W.; Baer, M.; Huebner, G.

    1983-01-01

    Gamma and electron radiation effects on wheat straw, oat straw, barley straw and rye straw are reported. In vitro and in vivo studies show that the digestibility of these agricultural rough materials can be increased up to 80% and more at high doses. The increase of the digestibility is connected with a depolymerisation of cellulose and hemicellulose. (author)

  12. Quality assurance in field radiation measurements

    International Nuclear Information System (INIS)

    Howell, W.P.

    1985-01-01

    In most cases, an ion chamber radiation measuring instrument is calibrated in a uniform gamma radiation field. This results in a uniform ionization field throughout the ion chamber. Measurement conditions encountered in the field often produce non-uniform ionization fields within the ion chamber, making determination of true dose rates to personnel difficult and prone to error. Extensive studies performed at Hanford have provided appropriate correction factors for use with one type of ion chamber instrument, the CP. Suitable corrections are available for the following distinct measurement circumstances: (1) contact measurements on large beta and gamma sources, (2) contact measurements on small beta and gamma sources, (3) contact measurements on small-diameter cylinders, (4) measurements in small gamma beams, and (5) measurements at a distance from large beta sources. Recommendations are made for the implementation of these correction factors, in the interest of improved quality assurance in field radiation measurements. 12 references, 10 figures

  13. Semiconductor dosimetry system for gamma and neutron radiation

    International Nuclear Information System (INIS)

    Savic, Z.; Pavlovic, Z.

    1995-01-01

    The semiconductor dosimetry system for gamma and neutron radiation based on pMOS transistor and PIN diode is described. It is intended for tactical or accidental personal dosimetry. The production steps are given. The temperature, dose and time (fading) response are reported. Hardware and software requirements which are needed for obtaining the desired measurement error are pointed. (author)

  14. Lunar occultations for gamma-ray source measurements

    Science.gov (United States)

    Koch, David G.; Hughes, E. B.; Nolan, Patrick L.

    1990-01-01

    The unambiguous association of discrete gamma-ray sources with objects radiating at other wavelengths, the separation of discrete sources from the extended emission within the Galaxy, the mapping of gamma-ray emission from nearby galaxies and the measurement of structure within a discrete source cannot presently be accomplished at gamma-ray energies. In the past, the detection processes used in high-energy gamma-ray astronomy have not allowed for good angular resolution. This problem can be overcome by placing gamma-ray detectors on the moon and using the horizon as an occulting edge to achieve arcsec resolution. For purposes of discussion, this concept is examined for gamma rays above 100 MeV for which pair production dominates the detection process and locally-generated nuclear gamma rays do not contribute to the background.

  15. Gamma-ray scatter methods applied to industrial measurement systems

    Energy Technology Data Exchange (ETDEWEB)

    Holstad, Marie Bueie

    2004-09-01

    Throughout the work presented in this dissertation it has been confirmed that the use of scattered gamma-radiation is a complex but useful tool in industrial measurement science. Scattered radiation has shown to be useful both when traditional measurement principles cannot be used (Chapter 4) and when more information about a system is needed than what is obtained with transmission measurements (Chapter 6). All three main projects (Chapters 4, 5 and 6) confirm that the sensitivity and accuracy of systems based on scattered gamma-radiation depends strongly on the geometry of the setup and that that presence of multiple scattered radiation makes the problems complex. Chapter 4 shows that multiple scattered gamma-radiation can be used for detection of changes in density where the dimensions are too large to use transmitted radiation. There is, however, an upper limit on the thickness of the absorbing medium also when scattered radiation is utilized. As seen in Chapter 5, multiple scattered gamma-radiation can in principle also be used in level gauges with very compact measurement geometries. The main challenges are the sensitivity to interfaces between materials with similar densities and low count rate. These challenges could not be overcome for level measurements in gravitational separator tanks. The results presented in Chapter 6 show that it is feasible to combine transmission and scatter measurements to characterize produced water in the oil and gas industry. (Author)

  16. Radiation protection measuring device SSM-1

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    Product information from the producer on a universal measuring instrument for alpha, beta and gamma radiation designed for stationary and field use by military, police and fire brigades. 4 figs. (qui)

  17. Impact of spectral smoothing on gamma radiation portal alarm probabilities

    International Nuclear Information System (INIS)

    Burr, T.; Hamada, M.; Hengartner, N.

    2011-01-01

    Gamma detector counts are included in radiation portal monitors (RPM) to screen for illicit nuclear material. Gamma counts are sometimes smoothed to reduce variance in the estimated underlying true mean count rate, which is the 'signal' in our context. Smoothing reduces total error variance in the estimated signal if the bias that smoothing introduces is more than offset by the variance reduction. An empirical RPM study for vehicle screening applications is presented for unsmoothed and smoothed gamma counts in low-resolution plastic scintillator detectors and in medium-resolution NaI detectors. - Highlights: → We evaluate options for smoothing counts from gamma detectors deployed for portal monitoring. → A new multiplicative bias correction (MBC) is shown to reduce bias in peak and valley regions. → Performance is measured using mean squared error and detection probabilities for sources. → Smoothing with the MBC improves detection probabilities and the mean squared error.

  18. Nuclear instrumentation for radiation measurement

    International Nuclear Information System (INIS)

    Madan, V.K.

    2012-01-01

    Nuclear radiation cannot be detected by human senses. Nuclear detectors and associated electronics facilitate detection and measurement of different types of radiation like alpha particles, beta particles, gamma radiation, and detection of neutrons. Nuclear instrumentation has evolved greatly since the discovery of radioactivity. There has been tremendous advancement in detector technology, electronics, computer technology, and development of efficient algorithms and methods for spectral processing to extract precisely qualitative and quantitative information of the radiation. Various types of detectors and nuclear instruments are presently available and are used for different applications. This paper describes nuclear radiation, its detection and measurement and associated electronics, spectral information extraction, and advances in these fields. The paper also describes challenges in this field

  19. Measuring the ash content of coal using natural gamma radiation. Medida del contenido de cenizas de carbones mediante radioactividad gamma natural

    Energy Technology Data Exchange (ETDEWEB)

    Legazpi, P V

    1990-10-01

    The receipt of consignments of coal at a power station can present serious problems. These concern not only the vast quantities of material involved and the associated problem of analysis, but also the decision as to whether the consignment is acceptable or not. A method based on natural radioactivity can provide an approximate analysis of ash content in under five minutes. In discussing approximate values it must be remembered that about 5% of the consignment is analysed, which implies some minimal sampling errors. This is also a technique which can be readily automated and adapted for use on lorries, rail cars and conveyors to provide a complete sampling system. It does not require special certification for the use of radiation equipment or any form of special protection. The accumulated error when using this method is amply compensated for by manpower costs and other expenditure resulting from sampling errors and the ease with which other methods may be fixed. The system yields very favourable economic benefits in the short term. 7 figs.

  20. Risk to Krakow population of gamma radiation from building materials

    International Nuclear Information System (INIS)

    Koperski, J.; Jasinska, M.

    1980-01-01

    A statistics was made of 7128 dwelling-houses considering their age, types of building materials and density of population. Gamma dose rates were measured by means of the TL and pressurized ionization chamber techniques inside 300 buildings and in 44 points outdoors over different kinds of beddings. Personal doses of 49 inhabitants of the buildings monitored were also recorded. By means of the spectrometric analysis of gamma radiation, and basing on a specially developed computational programme ''DOZA'' mean concentrations of 40 K, 226 Ra and 232 Th in 61 samples of building materials were evaluated. It was found that the mean personal dose rate as well as the mean indoor dose rate equals 5.7 urad/h /15.8 pGy/s/ and is about 19% higher than the dose outdoors which equals 4.8 urad/h /13.3 pGy/s/. Gamma dose rates inside the buildings made of gravel-sand concrete elements are about 10% lower than those in the buildings made of red bricks. Mean annual dose equivalent per capita from gamma radiation of building materials equals 40.6 mrem/y /406 uSv/y/, which constitutes about 57% of total annual dose equivalent per capita from all environmental sources of gamma radiation in the residential districts in Krakow. (author)

  1. Effect of gamma radiation on polyvinylpyrrolidone hydrogels

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, M.J.A.; Vásquez, P.A.S.; Alcântara, M.T.S.; Munhoz, M.M.L.; Lugão, A.B., E-mail: mariajhho@yahoo.com.br, E-mail: pavsalva@ipen.br, E-mail: ablugao@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    Polyvinylpyrrolidone (PVP) hydrogels have been investigated as drug delivery matrices for the treatment of wounds, such as cutaneous leishmaniasis, and matrices with silver nanoparticles for chronic wounds and burns. The preparation of such hydrogels can occur by various cross-linking methods, such as gamma, chemical, physical, among others. The most feasible for wound dressings is gamma irradiation from cobalt-60, because gamma irradiation simultaneously promotes crosslinking and sterilization, leaving the wound dressing ready for use. The objective of this work was to investigate the effect on physico- chemical properties of gamma radiation on PVP hydrogel according to the radiation absorbed dose variation. The PVP hydrogels were irradiated with doses of 5, 15, 25, 35, 45, 55, 65, 75 and 95kGy at dose rate of 5 kGy/h and characterized by swelling, thermogravimetric and mechanical analysis. Results shown a favorable dose range window for processing of these hydrogels related to the application. The results showed that mechanical strength was affected at doses starting at 25 kGy. (author)

  2. Effect of gamma radiation on polyvinylpyrrolidone hydrogels

    International Nuclear Information System (INIS)

    Oliveira, M.J.A.; Vásquez, P.A.S.; Alcântara, M.T.S.; Munhoz, M.M.L.; Lugão, A.B.

    2017-01-01

    Polyvinylpyrrolidone (PVP) hydrogels have been investigated as drug delivery matrices for the treatment of wounds, such as cutaneous leishmaniasis, and matrices with silver nanoparticles for chronic wounds and burns. The preparation of such hydrogels can occur by various cross-linking methods, such as gamma, chemical, physical, among others. The most feasible for wound dressings is gamma irradiation from cobalt-60, because gamma irradiation simultaneously promotes crosslinking and sterilization, leaving the wound dressing ready for use. The objective of this work was to investigate the effect on physico- chemical properties of gamma radiation on PVP hydrogel according to the radiation absorbed dose variation. The PVP hydrogels were irradiated with doses of 5, 15, 25, 35, 45, 55, 65, 75 and 95kGy at dose rate of 5 kGy/h and characterized by swelling, thermogravimetric and mechanical analysis. Results shown a favorable dose range window for processing of these hydrogels related to the application. The results showed that mechanical strength was affected at doses starting at 25 kGy. (author)

  3. Gamma-radiation induced synthesis of silver nanoparticles in gelatin and its application for radiotherapy dose measurements

    Science.gov (United States)

    Soliman, Y. S.

    2014-09-01

    A new gel dosimeter based on a radiation-sensitive silver nitrate was formulated and investigated for its potential use in γ-radiation treatment, from 3 to 100 Gy. This gel matrix is analyzed by UV-vis spectrophotometry and X-ray diffraction (XRD). Subjecting the gel to γ-rays produces Ag nanoparticles that exhibit a plasmon resonance absorption band at 450 nm. The intensity of this band increases linearly with the increase of absorbed dose up to 100 Gy. Stability of Ag nanoparticle in the dark at 6 °C is good. The overall uncertainty (2σ) of the gel dosimeter is estimated as ~4.65% in the dose range of 5-100 Gy.

  4. Exploring gamma radiation effect on exoelectron emission properties of bone

    Energy Technology Data Exchange (ETDEWEB)

    Zakaria, M.; Dekhtyar, Y.; Bogucharska, T.; Noskov, V. [Riga Technical Univ., Biomedical Engineering and Nanotechnology Institute (Latvia)

    2006-07-01

    Gamma radiation is used for radiation therapy to treat carcinogenic diseases including bone cancer. Ionising radiation kills carcinogenic calls. However, there are side effects of the gamma radiation on the bone surface electron structure. One of the effects is in the form of altering electron density of states of bone that, with time, influences biomedical reactions on bone life condition. (authors)

  5. Exploring gamma radiation effect on exoelectron emission properties of bone

    International Nuclear Information System (INIS)

    Zakaria, M.; Dekhtyar, Y.; Bogucharska, T.; Noskov, V.

    2006-01-01

    Gamma radiation is used for radiation therapy to treat carcinogenic diseases including bone cancer. Ionising radiation kills carcinogenic calls. However, there are side effects of the gamma radiation on the bone surface electron structure. One of the effects is in the form of altering electron density of states of bone that, with time, influences biomedical reactions on bone life condition. (authors)

  6. Gamma radiation sterilises bacteria-contaminated waste

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    The use of gamma radiation for the sterilisation of sewage and hospital waste etc., is briefly described. A sterilisation plant delivered by Sulzer is illustrated diagrammatically and its functioning explained, while a photograph illustrates a similar plant delivered by Geodel Systems, of Canada. The latter firm has adapted this type of plant for the radiolytical destruction of phenols, cyanides, alkyl benzenesulphonates and similar wastes. (JIW)

  7. Effects of gamma radiation on potato meristems

    International Nuclear Information System (INIS)

    Fernandez Gonzalez, J.; Garcia Collantes, M.A.

    1976-01-01

    The development of buds in potato tubers subjected to gamma radiation at doses of 3, 6, 8 and 12 Krad is studied at histological level. The irradiation was supplied at the beguining and end of the resting period, and the irradiated buds were observed at different stages of their development. Meristem's sensitivity depends on the state of activity involved at the moment of irradiation. Different parts of the meristem present different radiosensitivity, being the most radioresistant. (author) [es

  8. Elastic scattering of gamma radiation in solids

    International Nuclear Information System (INIS)

    Goncalves, O.D.

    1987-01-01

    The elastic scattering of gamma rays in solids is studied: Rayleigh scattering as well as Bragg scattering in Laue geometries. We measured Rayleigh cross sections for U, Pb, Pt, W, Sn, Ag, Mo, Cd, Zn, and Cu with gamma energies ranging from 60 to 660 KeV and angles between 5 0 and 140 0 . The experimental data are compared with form factor theories and second order perturbation theories and the limits of validity of both are established. In the 60 KeV experiment, a competition between Rayleigh and Bragg effects is found in the region of low momentum transfer. The Bragg experiments were performed using the gamma ray diffractometer from the Hahn-Meitner Institut (Berlin) with gammas of 317 KeV and angles up to 2 0 . In particular, we studied the effect of annealing in nearly perfect Czochralski Silicon crystals with high perfection in the crystallographic structure. The results are compared with Kinematical and Dynamical theories. (author)

  9. Modification of genetic effects of gamma radiation by laser radiation

    International Nuclear Information System (INIS)

    Khotyljova, L.V.; Khokhlova, S.A.; Khokhlov, I.V.

    1988-01-01

    Full text: Mutants obtained by means of ionizing radiation and chemical mutagens often show low viability and productivity that makes their use in plant breeding difficult. Methods reducing the destructive mutagen action on important functions of plant organism and increasing quality and practical value of induced mutants would be interesting. We believe that one method for increasing efficiency of experimental mutagenesis in plants is the application of laser radiation as a modificator of genetic effects of ionizing radiation and chemical mutagens. Combined exposure of wheat seedlings to a gamma radiation dose of 2 kR and to laser radiation with the wave length of 632.8 nm (power density - 20 mVt/cm 2 , exposure - 30 min.) resulted in reducing the chromosomal aberration percentage from 30.5% in the gamma version to 16.3% in the combined treatment version. A radiosensibilizing effect was observed at additional exposure of gamma irradiated wheat seeds to laser light with the wave length of 441.6 nm where chromosomal aberration percentage increased from 22% in the gamma-irradiation version to 31% in the combined treatment version. By laser radiation it is also possible to normalize mitotic cell activity suppressed by gamma irradiation. Additional seedling irradiation with the light of helium-neon laser (632.8 nm) resulted in recovery of mitotic cell activity from 21% to 62% and increasing the average content of DNA per nucleus by 10%. The influence of only laser radiation on plant variability was also studied and it was shown that irradiation of wheat seeds and seedlings with pulsed and continuous laser light of visible spectrum resulted in phenotypically altered forms in M 2 . Their frequencies was dependent upon power density, dose and radiation wave length. Number of altered forms increased in going from long-wave to short-wave spectrum region. In comparing efficiency of different laser types of pulsed and continuous exposure (dose - 180 J/cm 2 ) 2% of altered

  10. GammaCam trademark radiation imaging system

    International Nuclear Information System (INIS)

    1998-02-01

    GammaCam trademark, a gamma-ray imaging system manufactured by AIL System, Inc., would benefit a site that needs to locate radiation sources. It is capable of producing a two-dimensional image of a radiation field superimposed on a black and white visual image. Because the system can be positioned outside the radiologically controlled area, the radiation exposure to personnel is significantly reduced and extensive shielding is not required. This report covers the following topics: technology description; performance; technology applicability and alternatives; cost; regulatory and policy issues; and lessons learned. The demonstration of GammaCam trademark in December 1996 was part of the Large-Scale Demonstration Project (LSDP) whose objective is to select and demonstrate potentially beneficial technologies at the Argonne National Laboratory-East (ANL) Chicago Pile-5 Research Reactor (CP-5). The purpose of the LSDP is to demonstrate that by using innovative and improved decontamination and decommissioning (D and D) technologies from various sources, significant benefits can be achieved when compared to baseline D and D technologies

  11. Variation of Neutron Moderating Power on HDPE by Gamma Radiation

    International Nuclear Information System (INIS)

    Park, Kwang June; Ju, June Sik; Kang, Hee Young; Shin, Hee Sung; Kim, Ho Dong

    2009-01-01

    High density polyethylene (HDPE) is degraded due to a radiation-induced oxidation when it is used as a neutron moderator in a neutron counter for a nuclear material accounting of spent fuels. The HDPE exposed to the gamma-ray emitted from the fission products in a spent nuclear fuel results in a radiation-induced degradation which changes its original molecular structure to others. So a neutron moderating power variation of HDPE, irradiated by a gamma radiation, was investigated in this work. Five HDPE moderator structures were exposed to the gamma radiation emitted from a 60 Co source to a level of 10 5 -10 9 rad to compare their post-irradiation properties. As a result of the neutron measurement test with 5 irradiated HDPE structures and a neutron measuring system, it was confirmed that the neutron moderating power for the 105 rad irradiated HDPE moderator revealed the largest decrease when the un-irradiated pure one was used as a reference. It implies that a neutron moderating power variation of HDPE is not directly proportional to the integrated gamma dose rate. To clarify the cause of these changes, some techniques such as a FTIR, an element analysis and a densitometry were employed. As a result of these analyses, it was confirmed that the molecular structure of the gamma irradiated HDPEs had partially changed to others, and the contents of hydrogen and oxygen had varied during the process of a radiation-induced degradation. The mechanism of these changes cannot be explained in detail at present, and thus need further study

  12. Testing and Performance Validation of a Sensitive Gamma Ray Camera Designed for Radiation Detection and Decommissioning Measurements in Nuclear Facilities-13044

    Energy Technology Data Exchange (ETDEWEB)

    Mason, John A.; Looman, Marc R.; Poundall, Adam J.; Towner, Antony C.N. [ANTECH, A. N. Technology Ltd., Unit 6, Thames Park, Wallingford, Oxfordshire, OX10 9TA (United Kingdom); Creed, Richard; Pancake, Daniel [Argonne National Laboratory, 9700 South Cass Avenue, Lemont, IL 60439 (United States)

    2013-07-01

    This paper describes the measurements, testing and performance validation of a sensitive gamma ray camera designed for radiation detection and quantification in the environment and decommissioning and hold-up measurements in nuclear facilities. The instrument, which is known as RadSearch, combines a sensitive and highly collimated LaBr{sub 3} scintillation detector with an optical (video) camera with controllable zoom and focus and a laser range finder in one detector head. The LaBr{sub 3} detector has a typical energy resolution of between 2.5% and 3% at the 662 keV energy of Cs-137 compared to that of NaI detectors with a resolution of typically 7% to 8% at the same energy. At this energy the tungsten shielding of the detector provides a shielding ratio of greater than 900:1 in the forward direction and 100:1 on the sides and from the rear. The detector head is mounted on a pan/tile mechanism with a range of motion of ±180 degrees (pan) and ±90 degrees (tilt) equivalent to 4 π steradians. The detector head with pan/tilt is normally mounted on a tripod or wheeled cart. It can also be mounted on vehicles or a mobile robot for access to high dose-rate areas and areas with high levels of contamination. Ethernet connects RadSearch to a ruggedized notebook computer from which it is operated and controlled. Power can be supplied either as 24-volts DC from a battery or as 50 volts DC supplied by a small mains (110 or 230 VAC) power supply unit that is co-located with the controlling notebook computer. In this latter case both power and Ethernet are supplied through a single cable that can be up to 80 metres in length. If a local battery supplies power, the unit can be controlled through wireless Ethernet. Both manual operation and automatic scanning of surfaces and objects is available through the software interface on the notebook computer. For each scan element making up a part of an overall scanned area, the unit measures a gamma ray spectrum. Multiple

  13. Testing and Performance Validation of a Sensitive Gamma Ray Camera Designed for Radiation Detection and Decommissioning Measurements in Nuclear Facilities-13044

    International Nuclear Information System (INIS)

    Mason, John A.; Looman, Marc R.; Poundall, Adam J.; Towner, Antony C.N.; Creed, Richard; Pancake, Daniel

    2013-01-01

    This paper describes the measurements, testing and performance validation of a sensitive gamma ray camera designed for radiation detection and quantification in the environment and decommissioning and hold-up measurements in nuclear facilities. The instrument, which is known as RadSearch, combines a sensitive and highly collimated LaBr 3 scintillation detector with an optical (video) camera with controllable zoom and focus and a laser range finder in one detector head. The LaBr 3 detector has a typical energy resolution of between 2.5% and 3% at the 662 keV energy of Cs-137 compared to that of NaI detectors with a resolution of typically 7% to 8% at the same energy. At this energy the tungsten shielding of the detector provides a shielding ratio of greater than 900:1 in the forward direction and 100:1 on the sides and from the rear. The detector head is mounted on a pan/tile mechanism with a range of motion of ±180 degrees (pan) and ±90 degrees (tilt) equivalent to 4 π steradians. The detector head with pan/tilt is normally mounted on a tripod or wheeled cart. It can also be mounted on vehicles or a mobile robot for access to high dose-rate areas and areas with high levels of contamination. Ethernet connects RadSearch to a ruggedized notebook computer from which it is operated and controlled. Power can be supplied either as 24-volts DC from a battery or as 50 volts DC supplied by a small mains (110 or 230 VAC) power supply unit that is co-located with the controlling notebook computer. In this latter case both power and Ethernet are supplied through a single cable that can be up to 80 metres in length. If a local battery supplies power, the unit can be controlled through wireless Ethernet. Both manual operation and automatic scanning of surfaces and objects is available through the software interface on the notebook computer. For each scan element making up a part of an overall scanned area, the unit measures a gamma ray spectrum. Multiple radionuclides may be

  14. Radiation measurements and applications

    International Nuclear Information System (INIS)

    Griffin, H.C.; Rogers, W.L.

    1990-01-01

    This 1990 symposium was the seventh in a series of meetings which began in 1964. The 300 participants from 23 countries and the 65 oral and 77 poster presentations were more than double the size of the 1985 symposium. Some of this increase derived from the broadened scope of the program. Previous meetings emphasized X-rays and gamma-rays, but it has been increasingly clear that distinction from other forms of radiation (i.e., electrons, alpha-particles and neutrons) was contrived. This broadening led to papers in fields such as ''airport'' monitors and arms control. However, most of the increase in size of the symposium is simply a reflection of the vigorous activity, both academic and industrial in radiation measurements and their many applications. The papers in these Proceedings are arranged by major topic without regard to whether the paper was invited or contributed, oral or poster. Discussion, although an important part of the meeting, was not recorded and therefore is not included in the Proceedings

  15. Experimental arrangement for production and use of gamma radiation from neutron capture

    International Nuclear Information System (INIS)

    Mafra, Olga Yajgunovitch

    1969-01-01

    This dissertation presents the main characteristics and construction details of collimator system for gamma radiation emitted by atomic nuclei after capturing thermal neutrons. This construction was made in one of the cross channels of IEAR-1 swimming pool reactor of the Atomic Energy Institute of Sao Paulo, Brazil. The energies of gamma radiation available vary range from about 4 MeV and 11 MeV, discreetly. With this experimental arrangement is obtained: high intensity, good collimation and monochrome gamma radiation, important for conducting experiments with gamma radiation. It is also present in this dissertation the description of the techniques employed in determining the intensity of gamma radiation and the extent of contamination in the neutron beam as well as the program list GAMAU that adjusts the gamma spectrum photopeak taken as a Gaussian curve. We intend to use this experimental arrangement for the measurement of cross sections of photonuclear reactions

  16. New precise measurements of the $\\Xi^{0} \\to \\Lambda \\gamma$ and $\\Xi^{0} \\to \\Sigma^{0}\\gamma$ decay asymmetries

    CERN Document Server

    Batley, J R; Lazzeroni, C; Munday, D J; Patel, M; Slater, M W; Wotton, S A; Arcidiacono, R; Bocquet, G; Ceccucci, A; Cundy, D; Doble, N; Falaleev, V; Gatignon, L; Gonidec, A; Grafstrom, P; Kubischta, W; Mikulec, I; Norton, A; Panzer-Steindel, B; Rubin, P; Wahl, H; Goudzovski, E; Hristov, P; Kekelidze, V; Litov, L; Madigozhin, D; Molokanova, N; Potrebenikov, Yu; Stoynev, S; Zinchenko, A; Monnier, E; Swallow, E; Winston, R; Sacco, R; Walker, A; Baldini, W; Gianoli, A; Dalpiaz, P; Frabetti, P L; Martini, M; Petrucci, F; Savrie, M; Scarpa, M; Calvetti, M; Collazuol, G; Iacopini, E; Ruggiero, G; Bizzeti, A; Lenti, M; Veltri, M; Behler, M; Eppard, K; Eppard, M; Hirstius, A; Kleinknecht, K; Koch, U; Marouelli, P; Masetti, L; Moosbrugger, U; Morales-Morales, C; Peters, A; Wanke, R; Winhart, A; Dabrowski, A; Fonseca Martin, T; Velasco, M; Cenci, P; Lubrano, P; Pepe, M; Anzivino, G; Imbergamo, E; Lamanna, G; Michetti, A; Nappi, A; Petrucci, M C; Piccini, M; Valdata, M; Cerri, C; Fantechi, R; Costantini, F; Fiorini, L; Giudici, S; Pierazzini, G; Sozzi, M; Mannelli, I; Cheshkov, C; Cheze, J B; De Beer, M; Debu, P; Gouge, G; Marel, G; Mazzucato, E; Peyaud, B; Vallage, B; Holder, M; Maier, A; Ziolkowski, M; Biino, C; Cartiglia, N; Marchetto, F; Pastrone, N; Clemencic, M; Goy Lopez, S; Menichetti, E; Wislicki, W; Dibon, H; Jeitler, M; Markytan, M; Neuhofer, G; Widhalm, L

    2010-01-01

    The decay asymmetries of the weak radiative Hyperon decays $\\Xi^{0}\\to \\Lambda \\gamma$ and $\\Xi^{0} \\to \\Sigma^{0}\\gamma$ have been measured with high precision using data of the NA48/1 experiment at CERN. From about 52000 $\\Xi^{0}\\to \\Lambda \\gamma$ and 15000 $\\Xi^{0} \\to \\Sigma^{0}\\gamma$ decays, we obtain for the decay asymmetries $\\alpha_{\\Xi^{0}\\to \\Lambda\\gamma}$ = -0.704 +- 0.019$_{stat}$ +- 0.064$_{syst}$ and $\\alpha_{\\Xi^{0}\\to \\Sigma^{0}\\gamma}$ = -0.729 +- 0.030$_{stat}$ +- 0.076$_{syst}$, respectively. These results are in good agreement with previous experiments, but more precise.

  17. Applying the new gamma ray imager diagnostic to measurements of runaway electron Bremsstrahlung radiation in the DIII-D Tokamak (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, C. M., E-mail: coopercm@fusion.gat.com [Oak Ridge Associated Universities, Oak Ridge, Tennessee 37830 (United States); Pace, D. C.; Paz-Soldan, C.; Eidietis, N. W. [General Atomics, P.O. Box 85608, San Diego, California 92186-5608 (United States); Commaux, N.; Shiraki, D. [Oak Ridge National Laboratory, Oak Ridge, Tennessee 37830 (United States); Hollmann, E. M. [University of California, San Diego, La Jolla, California 92093-0533 (United States)

    2016-11-15

    A new gamma ray imager (GRI) is developed to probe the electron distribution function with 2D spatial resolution during runaway electron (RE) experiments at the DIII-D tokamak. The diagnostic is sensitive to 0.5–100 MeV gamma rays, allowing characterization of the RE distribution function evolution during RE growth and dissipation. The GRI consists of a lead “pinhole camera” mounted on the DIII-D midplane with 123 honeycombed tangential chords 20 cm wide that span the vessel interior. Up to 30 bismuth germanate (BGO) scintillation detectors capture RE bremsstrahlung radiation for Pulse Height Analysis (PHA) capable of discriminating up to 20 000 pulses per second. Digital signal processing routines combining shaping filters are performed during PHA to reject noise and record gamma ray energy. The GRI setup and PHA algorithms will be described and initial data from experiments will be presented. A synthetic diagnostic is developed to generate the gamma ray spectrum of a GRI channel given the plasma information and a prescribed distribution function. Magnetic reconstructions of the plasma are used to calculate the angle between every GRI sightline and orient and discriminate gamma rays emitted by a field-aligned RE distribution function.

  18. Applying the new gamma ray imager diagnostic to measurements of runaway electron Bremsstrahlung radiation in the DIII-D Tokamak (invited)

    International Nuclear Information System (INIS)

    Cooper, C. M.; Pace, D. C.; Paz-Soldan, C.; Eidietis, N. W.; Commaux, N.; Shiraki, D.; Hollmann, E. M.

    2016-01-01

    A new gamma ray imager (GRI) is developed to probe the electron distribution function with 2D spatial resolution during runaway electron (RE) experiments at the DIII-D tokamak. The diagnostic is sensitive to 0.5–100 MeV gamma rays, allowing characterization of the RE distribution function evolution during RE growth and dissipation. The GRI consists of a lead “pinhole camera” mounted on the DIII-D midplane with 123 honeycombed tangential chords 20 cm wide that span the vessel interior. Up to 30 bismuth germanate (BGO) scintillation detectors capture RE bremsstrahlung radiation for Pulse Height Analysis (PHA) capable of discriminating up to 20 000 pulses per second. Digital signal processing routines combining shaping filters are performed during PHA to reject noise and record gamma ray energy. The GRI setup and PHA algorithms will be described and initial data from experiments will be presented. A synthetic diagnostic is developed to generate the gamma ray spectrum of a GRI channel given the plasma information and a prescribed distribution function. Magnetic reconstructions of the plasma are used to calculate the angle between every GRI sightline and orient and discriminate gamma rays emitted by a field-aligned RE distribution function.

  19. $H\\rightarrow\\gamma\\gamma$ Coupling Measurements

    CERN Document Server

    Vasquez, Jared Gregory; The ATLAS collaboration

    2017-01-01

    Since the discovery of the Higgs boson, measurements of the decay rates and couplings have become paramount to an understanding of the new boson and its role in electroweak symmetry breaking and the mechanism of fermion mass generation. Despite the small branching ratio, the diphoton decay channel is a particularly attractive method to study these properties thanks to the clean signal peak and novel analysis strategy. This poster will present the latest 13 TeV measurements on the signal strengths (and their ratios) from various Higgs production modes in the diphoton decay channel. The measurements are further extended to include cross-section measurements in theory motivated kinematic regions as defined by the Simplified Template Cross-Section framework.

  20. Quality assurance of environmental gamma radiation monitoring in Slovenia

    International Nuclear Information System (INIS)

    Stuhec, M.; Zorko, B.; Mitic, D.; Miljanic, S.; Ranogajec-Komor, M.

    2006-01-01

    Environmental gamma radiation monitoring established in Slovenia consists of a network of multifunctional gamma monitors (MFMs) based on pairs of Geiger-Mueller counters and a network of measuring sites with high-sensitive thermoluminescence dosemeters. The measuring points are evenly spread across Slovenia, located at the meteorological stations and more densely on additional locations around the Krsko NPP. The MFM network has a 2-fold function with one sensor used for the purpose of early warning system in near surroundings of the NPP and the other, more sensitive, for natural radiation monitoring. The paper summarises activities to establish quality assurance of the environmental gamma radiation measurements in Slovenia, with a critical view of the results in comparison with the international standards and recommendations. While the results of linearity and energy dependence tests were satisfying, on-field intercomparison showed that the inherent signal of one of the monitors (MFM) has to be taken into account in the range of environmental background radiation. (authors)

  1. Variation of Natural Gamma Radiation in Isparta

    International Nuclear Information System (INIS)

    Akkurt, I.

    2004-01-01

    There is always a radiation in the earth, and its level is generated primarily by galactic cosmic rays (GCR), consisting of energetic nuclei of all naturally occurring elements, interacting with atmospheric constituents, through atomic and nuclear collisions. The other sources of natural radiations are global average background radiation from terrestrial sources such as soils, rocks ete. Background radiation levels in the atmosphere vary in intensity with latitude, altitude and phase of the solar cycle. Variation of natural radiation as a function of altitude, geological structure etc has been investigated. The measurements were performed using portable radiation counter which connected to NaI(Tl) probe

  2. The measurement of gamma ray induced heating in a mixed neutron and gamma ray environment

    International Nuclear Information System (INIS)

    Chiu, H.K.

    1991-10-01

    The problem of measuring the gamma heating in a mixed DT neutron and gamma ray environment was explored. A new detector technique was developed to make this measurement. Gamma heating measurements were made in a low-Z assembly irradiated with 14-Mev neutrons and (n, n') gammas produced by a Texas Nuclear Model 9400 neutron generator. Heating measurements were made in the mid-line of the lattice using a proportional counter operating in the Continuously-varied Bias-voltage Acquisition mode. The neutron-induced signal was separated from the gamma-induced signal by exploiting the signal rise-time differences inherent to radiations of different linear energy transfer coefficient, which are observable in a proportional counter. The operating limits of this measurement technique were explored by varying the counter position in the low-Z lattice, hence changing the irradiation spectrum observed. The experiment was modelled numerically to help interpret the measured results. The transport of neutrons and gamma rays in the assembly was modelled using the one- dimensional radiation transport code ANISN/PC. The cross-section set used for these calculations was derived from the ENDF/B-V library using the code MC 2 -2 for the case of DT neutrons slowing down in a low-Z material. The calculated neutron and gamma spectra in the slab and the relevant mass-stopping powers were used to construct weighting factors which relate the energy deposition in the counter fill-gas to that in the counter wall and in the surrounding material. The gamma energy deposition at various positions in the lattice is estimated by applying these weighting factors to the measured gamma energy deposition in the counter at those locations

  3. Propagation speed of gamma radiation in brass

    International Nuclear Information System (INIS)

    Cavalcante, Jose T.P.D.; Silva, Paulo R.J.; Saitovich, Henrique

    2009-01-01

    The propagation speed (PS) of visible light -represented by a short frequency range in the large frame of electromagnetic radiations (ER) frequencies- in air was measured during the last century, using a great deal of different methods, with high precision results being achieved. Presently, a well accepted value, with very small uncertainty, is c= 299,792.458 Km/s) (c reporting to the Latin word celeritas: 'speed swiftness'). When propagating in denser material media (MM), such value is always lower when compared to the air value, with the propagating MM density playing an important role. Until present, such studies focusing propagation speeds, refractive indexes, dispersions were specially related to visible light, or to ER in wavelengths ranges dose to it, and with a transparent MM. A first incursion in this subject dealing with γ-rays was performed using an electronic coincidence counting system, when the value of it's PS was measured in air, C γ(air) 298,300.15 Km/s; a method that went on with later electronic improvements. always in air. To perform such measurements the availability of a γ-radiation source in which two γ-rays are emitted simultaneously in opposite directions -as already used as well as applied in the present case- turns out to be essential to the feasibility of the experiment, as far as no reflection techniques could be used. Such a suitable source was the positron emitter 22 Na placed in a thin wall metal container in which the positrons are stopped and annihilated when reacting with the medium electrons, in such way originating -as it is very well established from momentum/energy conservation laws - two gamma-rays, energy 511 KeV each, both emitted simultaneously in opposite directions. In all the previous experiments were used photomultiplier detectors coupled to NaI(Tl) crystal scintillators, which have a good energy resolution but a deficient time resolution for such purposes. Presently, as an innovative improvement, were used BaF 2

  4. Co-60 gamma radiation assisted diffusion of iodine in polypropylene

    Energy Technology Data Exchange (ETDEWEB)

    Mathakari, N.L.; Bhoraskar, V.N. [Microtron Accelerator Laboratory, Department of Physics, University of Pune, Pune, Maharashtra 411007 (India); Dhole, S.D., E-mail: sanjay@physics.unipune.ernet.i [Microtron Accelerator Laboratory, Department of Physics, University of Pune, Pune, Maharashtra 411007 (India)

    2010-09-15

    Thin films of polypropylene having dimensions 50 mm x 15 mm x 350 {mu}m were immersed in 1 N iodine solution and then irradiated with Co-60 gamma radiation for the periods of 48, 96 and 144 h at the doses varying from 14.4 to 43.2 kGy. The films were also kept immersed in iodine solution for similar periods but without irradiation. Furthermore, the films were also directly-irradiated with Co-60 gamma radiation for similar periods and doses. The radiation-iodinated, plain-iodinated and directly-irradiated samples were characterized by using various techniques such as weight gain EDS, SEM, FTIR, UV-visible spectroscopy, contact angle and XRD. Weight gain, EDS and SEM collectively reveal that gamma irradiation enhances iodine intake in polypropylene. FTIR, EDS and contact angle measurements indicate that presence of iodine during irradiation resists radiation induced carbonylation of polypropylene. FTIR also shows presence of HOI (Hypoiodous acid) species instead of expected C-I bonds. UV-visible analysis unambiguously shows that presence of iodine enhances radiation induced band gap reduction process of polypropylene. XRD indicates that iodine decreases the crystallinity of polypropylene.

  5. Ornithogalum virens as a plant assay for beta and gamma radiation effects

    International Nuclear Information System (INIS)

    Herron, V.J.

    1979-01-01

    The purpose of this study was to determine if the monocotyledonous angiosperm, Ornithogalum virens (Quintanilha and Cabral, 1947), could be used in such a biological assay system. After exposing O. virens plants to acute ( 60 Co) and chronic ( 137 Cs) gamma radiation and internal beta radiation ( 32 P), lethality (LD 50 , LD 100 ), growth inhibition, and chromosome aberrations were investigated. The LD 50 and LD 100 for acute gamma radiation were estimated to be between 0.91 to 1.8 krad and less than 3.6 krad, respectively. Though growth inhibition and abnormal growth were observed in the acute and chronic gamma radiation studies, the changes in the growth of the plants were so variable that these parameters were found to be unreliable measures of radiation effects. Chromosome aberrations were a more reliable measure of radiation damage because linear relationships between total aberrations and dose were found for both gamma and beta radiation

  6. Portable neutron and gamma-radiation instruments

    International Nuclear Information System (INIS)

    Murray, W.S.; Butterfield, K.B.

    1990-01-01

    This paper reports on the design and building of a smart neutron and gamma-radiation detection systems with embedded microprocessors programmed in the FORTH language. These portable instruments can be battery-powered and can provide many analysis functions not available in most radiation detectors. Local operation of the instruments is menu-driven through a graphics liquid crystal display and hex keypad; remote operation is through a serial communications link. While some instruments simply count particles, others determine the energy of the radiation as well as the intensity. The functions the authors have provided include absolute source-strength determination. Feynmann variance analysis, sequential-probability ratio test, and time-history recording

  7. Origin of the diffuse background gamma radiation

    International Nuclear Information System (INIS)

    Stecker, F.W.; Puget, J.L.

    1974-05-01

    Recent observations have now provided evidence for diffuse background gamma radiation extending to energies beyond 100 MeV. There is some evidence of isotropy and implied cosmological origin. Significant features in the spectrum of this background radiation were observed which provide evidence for its origin in nuclear processes in the early stages of the big-band cosmology and tie in these processes with galaxy formation theory. A crucial test of the theory may lie in future observations of the background radiation in the 100 MeV to 100 GeV energy range which may be made with large orbiting spark-chamber satellite detectors. A discussion of the theoretical interpretations of present data, their connection with baryon symmetric cosmology and galaxy formation theory, and the need for future observations are given. (U.S.)

  8. Degradation of polycarbonate induced by gamma radiation

    International Nuclear Information System (INIS)

    Araujo, E.S. de; Guedes, S.M.L.

    1992-01-01

    Polycarbonate (PC) DUROLON amorphous, of molecular weight 22000 g/mol is used in medical supplies and may be sterilized by gamma radiation. The main chain scission and polymer degradation occur when this polymer is irradiated. The value G = 1.54 to DUROLON was obtained by equation: 10 6 /M v = 10 6 /M v' + 0.054 G R. The degradation without crosslinking it is not general rule to all types of polycarbonates; an comparison was realized. The infrared (FT-IR) spectra of irradiated PC by gamma rays with different doses showed the main chain scissions in carbonyl groups. The mechanism of polymeric degradation to DUROLON, observed by NMR spectra, is a recombination of phenoxy and phenyl radicals. (author)

  9. Gamma radiation a help to archeological woods

    International Nuclear Information System (INIS)

    Balibar, F.

    1981-01-01

    Waterlogged archeological wood falls into dust once extracted from the water. In order to prevent this destruction several processes have been thought up. In France, the Grenoble Nuclear Study Centre has developed a method of consolidation by resin impregnation and gamma irradiation. The object is first immersed in a vessel containing liquid resin which spreads throughout the wood thereby driving off the water. During the second stage of the treatment, the impregnated objects are irradiated by gamma radiation emitted by a rectangular grid of cobalt 60, so as to polymerize the resin inside the wood. The irradiated objects are Gallo-Roman statuettes discovered during digs at the sources of the river Seine. The wood consolidated right through to the core then becomes sufficiently solid for the restorer to work on the surface of these objects [fr

  10. In situ Ge(Li)-spectrometric measurements of gamma radiation from radon daughters under different weather conditions

    International Nuclear Information System (INIS)

    Finck, R.R.; Persson, B.R.R.

    1980-01-01

    The photon fluence from radionuclides in the ground and air was measured continuously with a Ge(Li) spectrometer during several weeks. The most prominent change in photon fluence rate near the ground was obtained during periods of heavy rainfall. Deposition of the short-lived radon daughters 214 Pb and 214 Bi on the ground surface can cause a temporary increase in the external absorbed dose rate of approximately 2μrads/h. The photon fluence from airborne radon daughters can be correlated to the degree of atmospheric stability. During stable conditions the photon fluence increases and the activity ratio 214 Bi/ 214 Pb decreases

  11. Gamma-gamma angular correlation measurement in the 100 Ru

    International Nuclear Information System (INIS)

    Kenchian, G.

    1990-01-01

    An angular correlation automatic spectrometer with two Ge(Li) detectors has been developed. The spectrometer moves automatically, controlled by a microcomputer. The gamma-gamma directional angular correlations of coincidence transitions have been measured in 100 Ru nuclide, following the β + and electron capture of 100 Rh. The 100 Rh source has been produced with 100 Ru(p,n) 100 Rh reaction, using the proton beam of the Cyclotron Accelerator insiding in 100 Ru isotope. (author)

  12. Gamma Radiation Effect on Titan Yellow Solutions

    International Nuclear Information System (INIS)

    El-Banna, M.

    2012-01-01

    In the present work, the radiation induced color bleaching of Titan yellow dye (TY) in different solvents has been studied. The color bleaching of the dye solutions upon irradiation was followed spectrophotometrically. The % color bleaching of the dyes in different solvent systems was plotted against different gamma irradiation doses used and was determined and the obtained relationships were found to be linear in most cases. These relationships were used as calibration curves to determine the unknown irradiation dose. The results obtained were reproducible and showed differences from calculated values ranging from 10 % to 15 %

  13. Characteristics of liver tissue for attenuate the gamma radiation

    International Nuclear Information System (INIS)

    Arcos P, A.; Rodriguez N, S.; Pinedo S, A.; Amador V, P.; Chacon R, A.; Vega C, H.R.

    2005-01-01

    It was determined the lineal attenuation coefficient of hepatic tissue before gamma radiation of a source of 137 Cs. When exposing organic material before X or gamma radiation fields, part of the energy of the photons is absorbed by the material, while another part crosses it without producing any effect. The quantity of energy that is absorbed is a measure of the dose that receives the material. The three main mechanisms by means of which the gamma rays interacting with the matter are: The Photoelectric Effect, the Compton dispersion and the Even production; the sum of these three processes is translated in the attenuation coefficient of the radiation. In this work we have used hepatic tissue of bovine, as substitute of the human hepatic tissue, and we have measured the lineal attenuation coefficient for photons of 0.662 MeV. Through a series of calculations we have determined the lineal attenuation coefficient for photons from 10 -3 to 10 -5 MeV and the measured coefficient was compared with the one calculated. (Author)

  14. Development of aerial gamma radiation survey system III

    International Nuclear Information System (INIS)

    Nagaoka, Toshi; Sakamoto, Ryuichi; Saito, Kimiaki; Tsutsumi, Masahiro; Moriuchi, Shigeru; Miyasaka, Satoshi.

    1985-01-01

    An aerial gamma-ray survey system using a helicopter has been developed since 1980 in order to perform quick gamma-ray survey covering a wide area. To form a line in the chain of the development, a series of flight measurements were conducted in Watarase reservoir, Tochigi prefecture, in which artificial gamma-ray fields were realized using 60 Co (100 and 400 mCi) and 137 Cs (100 and 300 mCi) point sources located on the ground. For the purpose of obtaining gamma-ray pulse height spectra in the field, 6 sets of NaI(Tl) scientillation detectors were prepared. These sets of detectors consist of ones for evaluation with high accuracy as the standard, for intercomparison with other authors' results, and for practical use. Two sets of them were boarded for each flight considering the exposure rate level and detector's sensitivity. The flight measurements were performed in a space of 20 m to 500 m in altitude, and 0 m to 500 m in horizontal distance from the source. The experimental results of the spatial gamma-ray distribution for each gamma-ray field satisfactorily agreed with calculational results by Monte Carlo method. Throughout this experiment, characteristics of this survey system and detectors were clarified, and versatile data processing and analysis code was completed. Also, a method for subtraction of background exposure rate in a field including artificial radiation component was discussed using energy band information, and the coefficients for this method were determined. These data obtained are expected to be used as widely applicable data not only for the interpretation of measured value, but also for analysis of environmental gamma-ray field. (author)

  15. Gamma radiation and HZE treatment of seedlings in Arabidopsis

    Data.gov (United States)

    National Aeronautics and Space Administration — Plants exhibit a robust transcriptional response to gamma radiation which includes the induction of transcripts required for homologous recombination and the...

  16. Insect disinfestation of packed dates by gamma-radiation

    International Nuclear Information System (INIS)

    Ahmed, M.S.H.; Hameed, A.A.; Kadhum, A.A.; Ali, S.R.

    1985-01-01

    The effect of gamma-radiation on insect disinfestation of commercially packed dry dates was studied in collaboration with the Iraqui Date Administration. The wrapping of ''window carton lunch boxes'' (each holding 250 g of dry dates, Zahdi variety) with polyethylene film, compared to cellophane, prevented reinfestation for a long period of storage if treated with 0.70 kGy of gamma-radiation. All live insects that were found in the irradiated boxes and tested were genetically sterile, and those in different developmental stages died within a short period of time without passing through metamorphosis. In all cases (treated or control batches), cellophane-sealed boxes proved to be more vulnerable to reinfestation. Dates packed in plastic cups, used for N/sub 2/ vacuum packaging, were also effectively disinfested by the same dose of radiation. The value of airtight packaging will certainly add to the advantage of the high penetration power of gamma-radiation relative to methyl bromide fumigation. Results of the assessment of the damaging ability of irradiated insects indicate that treatment of packed dates with 0.70 kGy is sufficient as far as quarantine measures are concerned where the possible increase in infestation rate, brought about by radio-resistant insect stages that usually constitute a small fraction in nature, is negligible

  17. CaSO4: Dy + Teflon dosimetric pellets for X, beta and gamma radiation detection

    International Nuclear Information System (INIS)

    Campos, L.L.; Lima, M.F.

    1987-08-01

    CaSO 4 : Dy + TEFLON dosimetric pellets with high sensitivity and low cost for X, beta and gamma radiation monitoring were studied and developed by the Dosimetric Material Production Laboratory of the Radiological Protection Departament and are disposable for sale. The thickness of the pellets are suitable for X, beta and gamma radiation measurements. The dosimetric properties of these pellets were determined and presented in this work. The results show the usefulness of 0,20mm thick pellets for beta radiation monitoring and 0,80mm thick pellets for x and gamma radiation detection. (Author) [pt

  18. Dosimetry of electron and gamma radiation with DL-alanine

    International Nuclear Information System (INIS)

    Costa, Z.M. da; Campos, L.L.

    1996-01-01

    A dosimetric method based on the quantitative determination of stabilised free radicals in irradiated crystalline DL-alanine by electron spin resonance (ESR) spectroscopy was proposed as early in 1962. Since then, alanine dosemeters owing to their unique properties have been investigated by many authors and used in dosimetry of various types of radiation, namely gamma rays, electron and neutrons. Alanine is a simple aminoacid, on irradiation at room temperature predominantly free paramagnetic radicals of the type CH 3 -CH-COOH are produced. This paper reports the application of powder DL-alanine/ESR dosemeter for measurement of absorbed dose of gamma radiation from 60 Co sources and reactor nucleus and electron beams from accelerator. The obtained results give useful information about the instrumental care necessary to obtain the needed overall accuracy in determination of absorbed dose. (author)

  19. Polycrystalline Materials as a Cold Neutron and Gamma Radiation Filter

    International Nuclear Information System (INIS)

    Habib, N.

    2009-01-01

    The total neutron cross-section of polycrystalline beryllium, graphite and iron has been calculated beyond their cut-off wavelength using a general formula. The computer Cold Filter code was developed in order to provide the required calculations. The code also permits the calculation of attenuation of reactor gamma radiation, The calculated neutron transmissions through polycrystalline Be graphite and iron at different temperatures were compared with the experimental data measured at the ETRR-1 reactor using two TOF spectrometers. An overall agreement is obtained between the formula fits and experimental data at different temperatures. A feasibility study is carried on using polycrystalline Be, graphite and iron an efficient filter for cold neutrons and gamma radiation.

  20. Mobile robot prototype detector of gamma radiation

    International Nuclear Information System (INIS)

    Vazquez C, R.M.; Duran V, M. D.; Jardon M, C. I.

    2014-10-01

    In this paper the technological development of a mobile robot prototype detector of gamma radiation is shown. This prototype has been developed for the purpose of algorithms implementation for the applications of terrestrial radiation monitoring of exposed sources, search for missing radioactive sources, identification and delineation of radioactive contamination areas and distribution maps generating of radioactive exposure. Mobile robot detector of radiation is an experimental technology development platform to operate in laboratory environment or flat floor facilities. The prototype integrates a driving section of differential configuration robot on wheels, a support mechanism and rotation of shielded detector, actuator controller cards, acquisition and processing of sensor data, detection algorithms programming and control actuators, data recording (Data Logger) and data transmission in wireless way. The robot in this first phase is remotely operated in wireless way with a range of approximately 150 m line of sight and can extend that range to 300 m or more with the use of signal repeaters. The gamma radiation detection is performed using a Geiger detector shielded. Scan detection is performed at various time sampling periods and diverse positions of discrete or continuous angular orientation on the horizon. The captured data are geographical coordinates of robot GPS (latitude and longitude), orientation angle of shield, counting by sampling time, date, hours, minutes and seconds. The data is saved in a file in the Micro Sd memory on the robot. They are also sent in wireless way by an X Bee card to a remote station that receives for their online monitoring on a laptop through an acquisition program by serial port on Mat Lab. Additionally a voice synthesizing card with a horn, both in the robot, periodically pronounced in Spanish, data length, latitude, orientation angle of shield and detected accounts. (Author)

  1. Influence of the temperature in the measurement of the gamma automatic probe Gamma Tracer

    International Nuclear Information System (INIS)

    Caveda R, C.A.; Dominguez L, O.; Alonso A, D.; Montalvan E, A.; Fabelo B, O.

    2006-01-01

    In the following work an analysis of the existent relationship among the measurement of the absorbed dose rate in air due to the environmental gamma radiation and the temperature, magnitudes measured to intervals of 10 minutes by the gamma probe Gamma Tracer located in the post of occident of the National Net of Environmental Radiological Surveillance (RNVRA), in the Center of Protection and Hygiene of the Radiations (CPHR) is made. For it its were analyzed near 100,000 measurements corresponding to the period 2004-2005. For a better processing and interpretation of the data, these were analyzed with one frequency time zone and monthly using the Gamma Red software to which was necessary to add it some options. Finally it was submitted the probe to a heating process inside a stove. The results of the carried out experiments confirmed that the absorbed dose rate in air due to the environmental gamma radiation depends potentially of the probe temperature in the range of environmental temperature to which is subjected daily the same one. (Author)

  2. Physiological quality of rice seed submitted to gamma radiation

    International Nuclear Information System (INIS)

    Miranda, Helen Lucia da Cruz; Tillmann, Maria Angela Andre; Meneghello, Geri Eduardo

    2009-01-01

    The objective of this research was to evaluate the effects of the gamma radiation ( 60 Co) on the physiological quality of rice seeds. The research was carried out through three tests; in the first test rice seeds were irradiated at dosages of 0; 1; 2.5 and 5Gy, while for the second and third tests the seeds were subjected to accelerated aging before being irradiated. For the second test the seeds were divided into wet and dry and both groups subjected to accelerated aging previous to irradiation at dosages of 0; 1; 2.5 and 5Gy. For the third test the seeds were dried after being subjected to accelerated aging, and then irradiated at dosages of 0, 10, 25 and 50Gy. To assess the physiological effects of the gamma radiation, all seeds were tested for germination and their germination speed index recorded. Seedling growth was graded through the measurement of the lengths of the first leaf and seminal root system and total seedling dry weight, across all tests. The enzymatic activity of acid phosphatase and alpha-amylase was measured on dry seeds from the second test. The results from all tests indicate that the applied gamma radiation dosages did not cause any changes to the physiological quality of rice seeds. (author)

  3. Gamma radiation scanning of nuclear waste storage tile holes

    International Nuclear Information System (INIS)

    Das, A.; Yue, S.; Sur, B.; Johnston, J.; Gaudet, M.; Wright, M.; Burton, N.

    2010-01-01

    Nuclear waste management facilities at Chalk River Laboratories use below-ground 'tile holes' to store solid waste from various activities such as medical radioisotope production. A silicon PIN (p-type-intrinsic-n-type semiconductor) diode based gamma radiation scanning system has been developed and used to profile the gamma radiation fields along the depth of waste storage tile holes by deploying the sensor into verification tubes adjacent to the tile holes themselves. The radiation field measurements were consistent with expected radiation fields in the tile holes based on administrative knowledge of the radioactive contents and their corresponding decay rates. Such measurements allow non-invasive verification of tile hole contents and provide input to the assessment of radiological risk associated with removal of the waste. Using this detector system, radioactive waste that has decayed to very low levels may be identified based on the radiation profile. This information will support planning for possible transfer of this waste to a licensed waste storage facility designed for low level waste, thus freeing storage space for possible tile hole re-use for more highly radioactive waste. (author)

  4. Sensory techniques for measuring differences in California navel oranges treated with doses of gamma-radiation below 0.6 Kgray

    International Nuclear Information System (INIS)

    O'Mahony, M.; Goldstein, L.R.

    1987-01-01

    Navel oranges from California were given low post harvest doses of gamma radiation: 0.32-0.37 and 0.52-0.60 KGy (32-37 and 52-60 Krad); they were compared with nonirradiated controls for visual appearance, flavor by mouth, odor, taste and taste after sweetness suppression by gymnema sylvestre. Practiced judges were used as an analytical tool, with minimum cross-sensory interference, while untrained subjects were used to determine whether changes might be distinguished by nonexperts. Differences were found in appearance, flavor, taste and odor although they were less extreme at the lower dose. Untrained judges could discriminate the juice at the higher irradiation level only

  5. Sterilization of peat by gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Parker, F E; Vincent, J M [New South Wales Univ., Kensington (Australia). School of Microbiology

    1981-01-01

    The effect of gamma-radiation on the survival of microorganisms has been quantified for the natural population of two types of peat. Data for several microbial types have been separately determined by regular plating and by indirect statistical probability estimates including, a wholly enclosed 'inverted-bottle' technique for higher dose levels to exclude any possibility of post-treatment contamination. The most persistent microorganisms at intermediate dosage (2.5-3.5 Mrad) were commonly a micrococcus (which closely resembled Micrococcus radiodurans) arthrobacter-like rods, myxobacteria and amoeboid forms. The persistent organisms all survived because of high resistance to ..gamma..-irradiation, not because of high initial numbers. The most numerous true bacteria (including spore-formers), actinomycetes, filamentous fungi and yeasts were all readily destroyed. Although the safety margin with the commercially recommended dose of 5 Mrad is low for some of the more resistant organisms, no change is justified at this stage since the organisms most likely to survive such a dose do not seem to seriously affect the subsequent growth and survival of rhizobia. Moreover there would be some risk of radiation-induced peat toxicity if higher doses were applied and some post-irradiation contamination will be difficult to avoid in commercial production.

  6. Alternative Measuring Approaches in Gamma Scanning on Spent Nuclear Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Sihm Kvenangen, Karen

    2007-06-15

    In the future, the demand for energy is predicted to grow and more countries plan to utilize nuclear energy as their source of electric energy. This gives rise to many important issues connected to nuclear energy, such as finding methods that can verify that the spent nuclear fuel has been handled safely and used in ordinary power producing cycles as stated by the operators. Gamma ray spectroscopy is one method used for identification and verification of spent nuclear fuel. In the specific gamma ray spectroscopy method called gamma scanning the gamma radiation from the fission products Cs-137, Cs-134 and Eu-154 are measured in a spent fuel assembly. From the results, conclusions can be drawn about the fuels characteristics. This degree project examines the possibilities of using alternative measuring approaches when using the gamma scanning method. The focus is on examining how to increase the quality of the measured data. How to decrease the measuring time as compared with the present measuring strategy, has also been investigated. The main part of the study comprises computer simulations of gamma scanning measurements. The simulations have been validated with actual measurements on spent nuclear fuel at the central interim storage, Clab. The results show that concerning the quality of the measuring data the conventional strategy is preferable, but with other starting positions and with a more optimized equipment. When focusing on the time aspect, the helical measuring strategy can be an option, but this needs further investigation.

  7. Alternative Measuring Approaches in Gamma Scanning on Spent Nuclear Fuel

    International Nuclear Information System (INIS)

    Sihm Kvenangen, Karen

    2007-06-01

    In the future, the demand for energy is predicted to grow and more countries plan to utilize nuclear energy as their source of electric energy. This gives rise to many important issues connected to nuclear energy, such as finding methods that can verify that the spent nuclear fuel has been handled safely and used in ordinary power producing cycles as stated by the operators. Gamma ray spectroscopy is one method used for identification and verification of spent nuclear fuel. In the specific gamma ray spectroscopy method called gamma scanning the gamma radiation from the fission products Cs-137, Cs-134 and Eu-154 are measured in a spent fuel assembly. From the results, conclusions can be drawn about the fuels characteristics. This degree project examines the possibilities of using alternative measuring approaches when using the gamma scanning method. The focus is on examining how to increase the quality of the measured data. How to decrease the measuring time as compared with the present measuring strategy, has also been investigated. The main part of the study comprises computer simulations of gamma scanning measurements. The simulations have been validated with actual measurements on spent nuclear fuel at the central interim storage, Clab. The results show that concerning the quality of the measuring data the conventional strategy is preferable, but with other starting positions and with a more optimized equipment. When focusing on the time aspect, the helical measuring strategy can be an option, but this needs further investigation

  8. Study of mechanical behavior of PMMA in bending and after UV irradiation and gamma radiation

    International Nuclear Information System (INIS)

    Todt, M.L.; Kienen, V.D.; Azevedo, E.C.

    2014-01-01

    PMMA is a polymer that has density similar to water and refractive index alike to glass. It has been used in the substitution to roofing tiles and coverages, affording to be exposed to UV radiation and gamma radiation. This paper had the objective to study the effect in the flexural proprieties of the PMMA exposed to these types of radiations and the evaluation of the wettability through a contact angle measurer. The PMMA specimens have been submitted to 1500 h of UVA radiation, 1500 h of UVC radiation and to 25kGy of gamma radiation. The results show that the PMMA. (author)

  9. EPR response of sucrose and microcrystalline cellulose to measure high doses of gamma radiation; Respuesta EPR de sacarosa y celulosa micro cristalina para medir altas dosis de radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Torijano, E.; Cruz, L.; Gutierrez, G.; Azorin, J.; Aguirre, F. [Universidad Autonoma Metropolitana, Unidad Iztapalapa, Av. San Rafael Atlixco 186, Col. Vicentina, 09340 Mexico D. F. (Mexico); Cruz Z, E., E-mail: eftc@xanum.uam.mx [UNAM, Instituto de Ciencias Nucleares, Circuito Exterior, Ciudad Universitaria, 04510 Mexico D. F. (Mexico)

    2015-10-15

    Solid dosimeters of sucrose and microcrystalline cellulose (Avicel Ph-102) were prepared, following the same process, in order to compare their EPR response against that of the l-alanine dosimeters considered as reference. All lots of dosimeters were irradiated with gamma radiation in Gamma beam irradiator with 8 kGy/h of the Nuclear Sciences Institute of UNAM. Doses ranged from 1 to 10 kGy respectively. We found that both the response of sucrose as microcrystalline cellulose were linear; however, the response intensity was, on average, twenty times more for sucrose. Comparing this against the EPR response of l-alanine in the range of doses, it was found that the response to sucrose is a third part; and microcrystalline cellulose is a sixtieth, approximately. The results agree with those found in the literature for sucrose, leaving open the possibility of investigating other dosage ranges for cellulose. (Author)

  10. Some problems of the detection of the high energy gamma-radiation in space

    Science.gov (United States)

    Fradkin, M. I.; Ginzburg, V. L.; Kurnosova, L. V.; Labensky, A. G.; Razorenov, L. A.; Rusakovich, M. A.; Topchiev, N. P.; Kaplin, V. A.; Runtso, M. F.; Gorchakov, E. V.; Ignatiev, P. P.

    1995-05-01

    Diffuse gamma radiation in the Galaxy has been measured with instruments onboard the COS-B and Compton Gamma Ray Observatory (CGRO) satellites from the tens of keV up to about 30 GeV. There is no experimental data at higher energies, but this data is very important for the spectrum of primary cosmic rays and the existence of neutralinos (hypothetical supersymmetrical particles which are supposed to constitute dark matter in the Galaxy and create gamma-quanta in the process of annihilation). The GAMMA-400 collaboration is working on the design of a telescope for gamma-ray measurements in the 10-1000 GeV range. The electronics of the GAMMA-400 eliminate some hindering effects, in particular the influence of backscattered gammas emitted by the very massive calorimeter (calorimeter albedo). The GAMMA-400 project may be realized in the near future if economic conditions in Russia are favorable.

  11. Radiation flux measuring device

    International Nuclear Information System (INIS)

    Corte, E.; Maitra, P.

    1977-01-01

    A radiation flux measuring device is described which employs a differential pair of transistors, the output of which is maintained constant, connected to a radiation detector. Means connected to the differential pair produce a signal representing the log of the a-c component of the radiation detector, thereby providing a signal representing the true root mean square logarithmic output. 3 claims, 2 figures

  12. Some neutron and gamma radiation characteristics of plutonium cermet fuel for isotopic power sources

    Science.gov (United States)

    Neff, R. A.; Anderson, M. E.; Campbell, A. R.; Haas, F. X.

    1972-01-01

    Gamma and neutron measurements on various types of plutonium sources are presented in order to show the effects of O-17, O-18 F-19, Pu-236, age of the fuel, and size of the source on the gamma and neutron spectra. Analysis of the radiation measurements shows that fluorine is the main contributor to the neutron yields from present plutonium-molybdenum cermet fuel, while both fluorine and Pu-236 daughters contribute significantly to the gamma ray intensities.

  13. New detectors of neutron, gamma- and X-radiations

    CERN Document Server

    Lobanov, N S

    2002-01-01

    Paper presents new detectors to record absorbed doses of neutron, gamma- and X-ray radiations within 0-1500 Mrad range. DBF dosimeter is based on dibutyl phthalate. EDS dosimeter is based on epoxy (epoxide) resin, while SD 5-40 detector is based on a mixture of dibutyl phthalate and epoxy resin. Paper describes experimental techniques to calibrate and interprets the measurement results of absorbed doses for all detectors. All three detectors cover 0-30000 Mrad measured does range. The accuracy of measurements is +- 10% independent (practically) of irradiation dose rates within 20-2000 rad/s limits under 20-80 deg C temperature

  14. Gamma Radiation Assessment In Kartini Reactor And Its Vicinity

    International Nuclear Information System (INIS)

    Yazid, M.; Supriyatni, E.; Maryono; Bastianudin, Aris

    2000-01-01

    Measurement to calculate dose assesment for gamma radiation in Kartini Reactor and its vicinity has been done whether on operated or un operated condition. Measurement was performed using height pressured ionization chamber, Reuther Stokes RS-112 production. Measurement location was determined based on distance variation inwardly and outwardly of reactor building and its vicinity. The result showed that the average dose rate in the reactor building when un operated is in the range of 11.4-38.6 mu rad/hour and when the reactor operated is 166.4-1910.9 mu rad/hour. While the vicinity of the reactor on operated condition the average dose rate is 34.4-38.6 mu rad/hour in un operated condition is 6.9-7.0 mu rad/hour. This result showed that the reactor operated did not rise the radiation exposure level in its vicinity. From the personnel assesment dose rate of gamma radiation is 28.54 mrem/week on operated condition, 0.90 mrem.week on un operated condition. While dose rate outside the reactor is 0.44 and 0.27 mrem/week for operated and un operated condition consecutively. This dose rate is still below maximum permissible dose than recommended by the national regulation of radiation protection from BAPETEN No. 01/Ka.BAPETEN/V-99

  15. Radiation breeding researches in gamma field. Results of researches

    International Nuclear Information System (INIS)

    Morishita, Toshikazu

    2006-01-01

    Abstract of radiation breeding researches and outline of gamma field in IRB (Institute of Radiation Breeding) are described. The gamma field is a circular field of 100 m radius with 88.8TBqCo-60 source at the center. The field is surrounded by a shielding dike of 8 m in height. The effects of gamma irradiation on the growing plants, mutant by gamma radiation and plant molecular biological researches using mutant varieties obtained by the gamma field are explained. For examples, Japanese pear, chrysanthemum, Cytisus, Eustoma grandiflorum, Manila grass, tea and rose are reported. The mutant varieties in the gamma field, nine mutant varieties of flower colors in chrysanthemum, evergreen mutant lines in Manila grass, selection of self-compatible mutants in tea plant, and the plants of the gamma field recently are shown. (S.Y.)

  16. Preservation of yams by gamma radiation

    International Nuclear Information System (INIS)

    Bansa, D.; Appiah, V.

    1999-01-01

    Loss of yam in storage due to sprouting is very high. There is the need to investigate the possibility of inhibiting the sprouting of local varieties of yams using gamma radiation. The effect of radiation on the storage yams and the functionality of the irradiated yams in the Ghanaian food system was studied. Yams were purchased from a farm in Nkwanta. Some of the yams were irradiated at an average dose of 120 Gy and a dose rate of 114 Gy/hr. The irradiated yams were stored alongside unirradiated controls in a specially constructed barn and on the ground as is traditionally done by the farmers at ambient temperature for 6 months. The stored yams were processed into some local food products, namely, boiled yam, fried yam and fufu and sensory evaluation carried out on them using the Hedonic Scale Test and analysed by Analysis of variance. Results indicated that all the unirradiated yams sprouted by the 3rd month of storage. 6.2% of the irradiated yams stored on the barn and 18.0% of those stored on the ground sprouted. 2.26% irradiated and 8.0% unirradiated yams stored on the barn compared to 22.0% and 12.0% respectively of the yams stored on the ground got rotten within the storage period. Food products made from irradiated yams were preferred to those made from the unirradiated yams in terms of texture, taste, colour and general acceptability. The results suggest that gamma radiation dose of 120 Gy effectively inhibited the sprouting of yams for 6 months under tropical ambient conditions. There was less rotting in the yams stored in the barn compared to those stored on the ground. There was also less rotting in the irradiated yams stored in the barn in comparison with the unirradiated ones. Food products made from irradiated yams were judged better in quality than those made from the unirradiated ones. (au)

  17. Effect of gamma radiation on graphite - PTFE dry lubrication system

    Science.gov (United States)

    Singh, Sachin; Tyagi, Mukti; Seshadri, Geetha; Tyagi, Ajay Kumar; Varshney, Lalit

    2017-12-01

    An effect of gamma radiation on lubrication behavior of graphite -PTFE dry lubrication system has been studied using (TR-TW-30L) tribometer with thrust washer attachment in plane contact. Different compositions of graphite and PTFE were prepared and irradiated by gamma rays. Gamma radiation exposure significantly improves the tribological properties indicated by decrease in coefficient of friction and wear properties of graphite -PTFE dry lubrication system. SEM and XRD analysis confirm the physico-chemical modification of graphite-PTFE on gamma radiation exposure leading to a novel dry lubrication system with good slip and anti friction properties.

  18. Development of aerial gamma radiation survey system, 1

    International Nuclear Information System (INIS)

    Tsutsumi, Masahiro; Saito, Komei; Sakamoto, Ryuichi; Nagaoka, Toshi; Moriuchi, Shigeru

    1986-05-01

    JAERI has started to develop an aerial gamma radiation survey system by a helicopter in 1980. The development of measuring instruments, the experiments in the field of natural and artificial radiation sources, and the imaginary emergency survey at a real site, were executed. This report describes mainly about the hardware and software of this system. The system consists of gamma-ray measuring instruments with NaI(Tl) scintillation detectors, microwave positioning instruments, and a data processing system for postflight data. A foreign-made geological survey system is improved on for radiation measurements. For covering the wide radiation range, detectors of various shapes and sizes are prepared, from a large volume detector, DET-1024 - four 4'' x 4'' x 16'' crystals assembly - to a 2'' diameter x 2'' NaI(Tl) crystal. Radiation and position data are recorded on a magnetic tape, and computer-processed afterwards. Moreover, scene below flight courses and internal communication are recorded on video tape with the information of clock and position superimposed. In consequence of field experiments carried out five times, basic radiation data for evaluating airborne acquired data are accumulated, and flight survey procedures are established. As more practical use, a system has been produced more compactly and functionally. Exposure rates (> 1 mR/h), energy distribution spectra, and energy window counts are obtained for radiation data. Using the Spectrum-Dose Conversion Method, the accurate exposure rates are directly calculated from pulse height spectra. Numerical tables of G(E) function converting pulse height spectra into exposures are shown in this report. As regards the analysis of survey data, process codes have been completed with either large-computer or mini-computer. (author)

  19. A rotating-slit-collimator-based gamma radiation mapper.

    Science.gov (United States)

    Nilsson, Jonas M C; Finck, Robert R; Rääf, Christopher L

    2017-10-01

    For situations with radioactive material out of control where it may be physically difficult or prohibited to access areas close to the source, measurements from distance may be the only way to assess the radiation environment. Using collimated detectors will provide means to locate the direction of the radiation from the source. To investigate the possibilities of mapping gamma emitting radioactive material in a closed non-enterable area, a tentative system for mapping radioactive materials from a distance was built. The system used a computer controlled cylindrical rotating slit collimator with a high purity germanium detector placed in the cylinder. The system could be placed on a car-towed trailer, with the centre of the detector about 1.4 m above ground. Mapping was accomplished by the use of a specially developed image reconstruction algorithm that requires measurements from two or more locations around the area to be investigated. The imaging capability of the system was tested by mapping an area, 25 by 25 m 2 , containing three 330 MBq 137 Cs point sources. Using four locations outside the area with about 20 min measuring time in each location and applying the image reconstruction algorithm on the deconvoluted data, the system indicated the three source locations with an uncertainty of 1-3 m. The results demonstrated the potential of using collimated mobile gamma radiometry combined with image reconstruction to localize gamma sources inside non-accessible areas. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. The effect of gamma-radiation on bilirubin

    International Nuclear Information System (INIS)

    Iqbal, M.S.; Shad, M.A.; Akhtar, M.I.

    2001-01-01

    The effect of gamma-radiations on bilirubin, in vitro, has been studied. It was found that gamma-radiation causes oxidation of bilirubin to biliverdine as one of the products. The likely implication of this effect in transformation of bilirubin to excretable products, in vino, in case of jaundice is discussed. (author)

  1. Effect of gamma radiation on optical and electrical properties of ...

    Indian Academy of Sciences (India)

    Wintec

    Tellurium dioxide; thin films; optical bandgap; gamma radiation dose; dosimeter. 1. Introduction. It is now ... material to ionizing radiations (such as X-rays, gamma rays, beta ..... Mag. 19 19. Mott N F and Davis E 1979 Electronic process in non-.

  2. Bone densitometry in dogs using gamma radiation

    International Nuclear Information System (INIS)

    Oliveira, A.L.B.; Costa, V.E.; Rezende, M.A.; Grossklauss, D.B.B.F.; Oliveira, T.B.

    2010-01-01

    Full text. The purpose of this work came from the possibility of joining similar methodologies for determination of density, used in different areas, and provide more precise values of bone density by analyzing the mass attenuation coefficient. For over 20 years, The Applied Physics Laboratory, Department of Physics and Biophysics, IBB- UNESP, Botucatu campus, has been working in the determination of density in different areas, using the methods of immersion and gamma radiation attenuation. The results presented have excellent precision, due to the facility in obtaining and preparing samples, coupled to the large experience in the area. This study aims to determine the bone density of samples of mongrel dogs (dogs without defined breed) by the immersion method; to determine the mass attenuation coefficient of bones samples of mongrel dogs with a gamma radiation source; to discuss and to evaluate the methodological aspects involved in the optic densitometry used nowadays, presenting its advantages and disadvantages and, finally, to examine the effect of animal weight, age and sex on bone densitometry of medium-sized dogs. For this study, we use upper limbs samples, at the joint region humerus-radio-ulnar of after death mongrel dogs, assigned by the Department of Pathology, Faculty of Animal Science and Veterinary Medicine (UNESP-Botucatu) and by the Kennel of the city of Araras, Sao Paulo. This work is performed in three stages. In the first step is determined the density by the method of immersion in water, in the second step, is obtained the mass coefficient attenuation and, finally, in the third step are discussed the implemented methods and evaluate the density bone samples to establish correlations with the age, weight and sex parameters of each group of animals. Based on this methodology , we can find the average value for the mass attenuation coefficient of gamma radiation with energy 59,6, find variations in the values of bone densitometry in the same bone

  3. Higher-order multipole amplitude measurement in psi ' -> gamma chi(c2)

    NARCIS (Netherlands)

    Ablikim, M.; Achasov, M. N.; Alberto, D.; An, F. F.; An, Q.; An, Z. H.; Bai, J. Z.; Baldini, R.; Ban, Y.; Becker, J.; Berger, N.; Bertani, M.; Bian, J. M.; Boger, E.; Bondarenko, O.; Boyko, I.; Briere, R. A.; Bytev, V.; Cai, X.; Calcaterra, A. C.; Cao, G. F.; Chang, J. F.; Chelkov, G.; Chen, G.; Chen, H. S.; Chen, J. C.; Chen, M. L.; Chen, S. J.; Chen, Y.; Chen, Y. B.; Cheng, H. P.; Chu, Y. P.; Cronin-Hennessy, D.; Dai, H. L.; Dai, J. P.; Dedovich, D.; Deng, Z. Y.; Denysenko, I.; Destefanis, M.; Ding, Y.; Dong, L. Y.; Dong, M. Y.; Du, S. X.; Fang, J.; Fang, S. S.; Feng, C. Q.; Fu, C. D.; Fu, J. L.; Gao, Y.; Geng, C.; Goetzen, K.; Gong, W. X.; Greco, M.; Gu, M. H.; Gu, Y. T.; Guan, Y. H.; Guo, A. Q.; Guo, L. B.; Guo, Y. P.; Han, Y. L.; Hao, X. Q.; Harris, F. A.; He, K. L.; He, M.; He, Z. Y.; Heng, Y. K.; Hou, Z. L.; Hu, H. M.; Hu, J. F.; Hu, T.; Huang, B.; Huang, G. M.; Huang, J. S.; Huang, X. T.; Huang, Y. P.; Hussain, T.; Ji, C. S.; Ji, Q.; Ji, X. B.; Ji, X. L.; Jia, L. K.; Jiang, L. L.; Jiang, X. S.; Jiao, J. B.; Jiao, Z.; Jin, D. P.; Jin, S.; Jing, F. F.; Kalantar-Nayestanaki, N.; Kavatsyuk, M.; Kuehn, W.; Lai, W.; Lange, J. S.; Leung, J. K. C.; Li, C. H.; Li, Cheng; Li, Cui; Li, D. M.; Li, F.; Li, G.; Li, H. B.; Li, J. C.; Li, K.; Li, Lei; Li, N. B.; Li, Q. J.; Li, S. L.; Li, W. D.; Li, W. G.; Li, X. L.; Li, X. N.; Li, X. Q.; Li, X. R.; Li, Z. B.; Liang, H.; Liang, Y. F.; Liang, Y. T.; Liao, X. T.; Liu, B. J.; Liu, C. L.; Liu, C. X.; Liu, C. Y.; Liu, F. H.; Liu, Fang; Liu, Feng; Liu, H.; Liu, H. B.; Liu, H. H.; Liu, H. M.; Liu, H. W.; Liu, J. P.; Liu, K.; Liu, K.; Liu, K. Y.; Liu, Q.; Liu, S. B.; Liu, X.; Liu, X. H.; Liu, Y. B.; Liu, Y. W.; Liu, Yong; Liu, Z. A.; Liu, Zhiqiang; Liu, Zhiqing; Loehner, H.; Lu, G. R.; Lu, H. J.; Lu, J. G.; Lu, Q. W.; Lu, X. R.; Lu, Y. P.; Luo, C. L.; Luo, M. X.; Luo, T.; Luo, X. L.; Lv, M.; Ma, C. L.; Ma, F. C.; Ma, H. L.; Ma, Q. M.; Ma, S.; Ma, T.; Ma, X.; Ma, X. Y.; Maggiora, M.; Malik, Q. A.; Mao, H.; Mao, Y. J.; Mao, Z. P.; Messchendorp, J. G.; Min, J.; Min, T. J.; Mitchell, R. E.; Mo, X. H.; Muchnoi, N. Yu; Nefedov, Y.; Nikolaev, I. B.; Ning, Z.; Olsen, S. L.; Ouyang, Q.; Pacetti, S.; Park, J. W.; Pelizaeus, M.; Peters, K.; Ping, J. L.; Ping, R. G.; Poling, R.; Pun, C. S. J.; Qi, M.; Qian, S.; Qiao, C. F.; Qin, X. S.; Qiu, J. F.; Rashid, K. H.; Rong, G.; Ruan, X. D.; Sarantsev, A.; Schulze, J.; Shao, M.; Shen, C. P.; Shen, X. Y.; Sheng, H. Y.; Shepherd, M. R.; Song, X. Y.; Spataro, S.; Spruck, B.; Sun, D. H.; Sun, G. X.; Sun, J. F.; Sun, S. S.; Sun, X. D.; Sun, Y. J.; Sun, Y. Z.; Sun, Z. J.; Sun, Z. T.; Tang, C. J.; Tang, X.; Tian, H. L.; Toth, D.; Varner, G. S.; Wang, B.; Wang, B. Q.; Wang, K.; Wang, L. L.; Wang, L. S.; Wang, M.; Wang, P.; Wang, P. L.; Wang, Q.; Wang, Q. J.; Wang, S. G.; Wang, X. L.; Wang, Y. D.; Wang, Y. F.; Wang, Y. Q.; Wang, Z.; Wang, Z. G.; Wang, Z. Y.; Wei, D. H.; Wen, Q. G.; Wen, S. P.; Wiedner, U.; Wu, L. H.; Wu, N.; Wu, W.; Wu, Z.; Xiao, Z. J.; Xie, Y. G.; Xiu, Q. L.; Xu, G. F.; Xu, G. M.; Xu, H.; Xu, Q. J.; Xu, X. P.; Xu, Y.; Xu, Z. R.; Xu, Z. Z.; Xue, Z.; Yan, L.; Yan, W. B.; Yan, Y. H.; Yang, H. X.; Yang, T.; Yang, Y.; Yang, Y. X.; Ye, H.; Ye, M.; Ye, M. H.; Yu, B. X.; Yu, C. X.; Yu, S. P.; Yuan, C. Z.; Yuan, W. L.; Yuan, Y.; Zafar, A. A.; Zallo, A.; Zeng, Y.; Zhang, B. X.; Zhang, B. Y.; Zhang, C.; Zhang, C. C.; Zhang, D. H.; Zhang, H. H.; Zhang, H. Y.; Zhang, J.; Zhang, J. Q.; Zhang, J. W.; Zhang, J. Y.; Zhang, J. Z.; Zhang, L.; Zhang, S. H.; Zhang, T. R.; Zhang, X. J.; Zhang, X. Y.; Zhang, Y.; Zhang, Y. H.; Zhang, Y. S.; Zhang, Z. P.; Zhang, Z. Y.; Zhao, G.; Zhao, H. S.; Zhao, Jiawei; Zhao, Jingwei; Zhao, Lei; Zhao, Ling; Zhao, M. G.; Zhao, Q.; Zhao, S. J.; Zhao, T. C.; Zhao, X. H.; Zhao, Y. B.; Zhao, Z. G.; Zhao, Z. L.; Zhemchugov, A.; Zheng, B.; Zheng, J. P.; Zheng, Y. H.; Zheng, Z. P.; Zhong, B.; Zhong, J.; Zhong, L.; Zhou, L.; Zhou, X. K.; Zhou, X. R.; Zhu, C.; Zhu, K.; Zhu, K. J.; Zhu, S. H.; Zhu, X. L.; Zhu, X. W.; Zhu, Y. S.; Zhu, Z. A.; Zhuang, J.; Zou, B. S.; Zou, J. H.; Zuo, J. X.

    2011-01-01

    Using 106 x 10(6) psi' events collected with the BESIII detector at the BEPCII storage ring, the higher-order multipole amplitudes in the radiative transition psi' -> gamma chi(c2) -> gamma pi(+)pi(-)/gamma K+K- are measured. A fit to the chi(c2) production and decay angular distributions yields M2

  4. Effects of gamma radiation on rabbit lens

    International Nuclear Information System (INIS)

    Ordahl, J.N.; Gorthy, W.C.

    1982-01-01

    Eyes of young New Zealand white rabbits were irradiated with 2000 rads of gamma radiation ( 60 Co) and the eyes removed at 2, 8, 16, and 30 days post-irradiation for electron microscopic analysis. Lenses were treated histochemically for acid phosphatase localization to examine the role of lysosomal enzymes in the early development of radiation cataracts. Intercellularly located acid phosphatase reaction product, noted in the epithelium and subjacent cortex, was more prevalent after irradiation, especially in central and transitional epithelial zones. In the central zone small vesicles typically were most numerous in areas of extensive intercellular reaction product. The occurrence of discrete packets of reaction product within the vesicles and the adjoining intercellular space, plus the resemblance of the peripheral vesicles to small Golgi vesicles also containing reaction product, suggested an exocytotic release of the enzyme. These appearances suggest that lysosomal hydrolases are released extracellularly by a secretory mechanism accelerated by radiation and that these hydrolases may play a role in both physiological and pathological functions of the lens. (author)

  5. Differential sensitivity of Chironomus and human hemoglobin to gamma radiation

    International Nuclear Information System (INIS)

    Gaikwad, Pallavi S.; Panicker, Lata; Mohole, Madhura; Sawant, Sangeeta; Mukhopadhyaya, Rita; Nath, Bimalendu B.

    2016-01-01

    Chironomus ramosus is known to tolerate high doses of gamma radiation exposure. Larvae of this insect possess more than 95% of hemoglobin (Hb) in its circulatory hemolymph. This is a comparative study to see effect of gamma radiation on Hb of Chironomus and humans, two evolutionarily diverse organisms one having extracellular and the other intracellular Hb respectively. Stability and integrity of Chironomus and human Hb to gamma radiation was compared using biophysical techniques like Dynamic Light Scattering (DLS), UV-visible spectroscopy, fluorescence spectrometry and CD spectroscopy after exposure of whole larvae, larval hemolymph, human peripheral blood, purified Chironomus and human Hb. Sequence- and structure-based bioinformatics methods were used to analyze the sequence and structural similarities or differences in the heme pockets of respective Hbs. Resistivity of Chironomus Hb to gamma radiation is remarkably higher than human Hb. Human Hb exhibited loss of heme iron at a relatively low dose of gamma radiation exposure as compared to Chironomus Hb. Unlike human Hb, the heme pocket of Chironomus Hb is rich in aromatic amino acids. Higher hydophobicity around heme pocket confers stability of Chironomus Hb compared to human Hb. Previously reported gamma radiation tolerance of Chironomus can be largely attributed to its evolutionarily ancient form of extracellular Hb as evident from the present study. -- Highlights: •Comparison of radiation tolerant Chironomus Hb and radiation sensitive Human Hb. •Amino acid composition of midge and human heme confer differential hydrophobicity. •Heme pocket of evolutionarily ancient midge Hb provide gamma radiation resistivity.

  6. Differential sensitivity of Chironomus and human hemoglobin to gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Gaikwad, Pallavi S. [Stress Biology Research Laboratory, Department of Zoology, Savitribai Phule University, Pune, 411007 (India); Molecular Biology Division, Bhabha Atomic Research Centre, Trombay, Mumbai, 400085 (India); Panicker, Lata [Solid State Physics Division, Bhabha Atomic Research Centre, Trombay, Mumbai, 400085 (India); Mohole, Madhura; Sawant, Sangeeta [Bioinformatics Center, Savitribai Phule Pune University, Pune, 411007 (India); Mukhopadhyaya, Rita [Molecular Biology Division, Bhabha Atomic Research Centre, Trombay, Mumbai, 400085 (India); Nath, Bimalendu B., E-mail: bbnath@gmail.com [Stress Biology Research Laboratory, Department of Zoology, Savitribai Phule University, Pune, 411007 (India)

    2016-08-05

    Chironomus ramosus is known to tolerate high doses of gamma radiation exposure. Larvae of this insect possess more than 95% of hemoglobin (Hb) in its circulatory hemolymph. This is a comparative study to see effect of gamma radiation on Hb of Chironomus and humans, two evolutionarily diverse organisms one having extracellular and the other intracellular Hb respectively. Stability and integrity of Chironomus and human Hb to gamma radiation was compared using biophysical techniques like Dynamic Light Scattering (DLS), UV-visible spectroscopy, fluorescence spectrometry and CD spectroscopy after exposure of whole larvae, larval hemolymph, human peripheral blood, purified Chironomus and human Hb. Sequence- and structure-based bioinformatics methods were used to analyze the sequence and structural similarities or differences in the heme pockets of respective Hbs. Resistivity of Chironomus Hb to gamma radiation is remarkably higher than human Hb. Human Hb exhibited loss of heme iron at a relatively low dose of gamma radiation exposure as compared to Chironomus Hb. Unlike human Hb, the heme pocket of Chironomus Hb is rich in aromatic amino acids. Higher hydophobicity around heme pocket confers stability of Chironomus Hb compared to human Hb. Previously reported gamma radiation tolerance of Chironomus can be largely attributed to its evolutionarily ancient form of extracellular Hb as evident from the present study. -- Highlights: •Comparison of radiation tolerant Chironomus Hb and radiation sensitive Human Hb. •Amino acid composition of midge and human heme confer differential hydrophobicity. •Heme pocket of evolutionarily ancient midge Hb provide gamma radiation resistivity.

  7. Orchid flowers tolerance to gamma-radiation

    International Nuclear Information System (INIS)

    Kikuchi, Olivia Kimiko

    2000-01-01

    Cut flowers are fresh goods that may be treated with fumigants such as methyl bromide to meet the needs of the quarantine requirements of importing countries. Irradiation is a non-chemical alternative to substitute the methyl bromide treatment of fresh products. In this research, different cut orchids were irradiated to examine their tolerance to gamma-rays. A 200 Gy dose did inhibit the Dendrobium palenopsis buds from opening, but did not cause visible damage to opened flowers. Doses of 800 and 1000 Gy were damaging because they provoked the flowers to drop from the stem. Cattleya irradiated with 750 Gy did not show any damage, and were therefore eligible for the radiation treatment. Cymbidium tolerated up to 300 Gy and above this dose dropped prematurely. On the other hand, Oncydium did not tolerate doses above 150 Gy.(author)

  8. Gamma radiation effects on liofilized human serum

    International Nuclear Information System (INIS)

    Padron Soler, E.; Romay Penabad, Z.; Chavez Ardanza, A.; Hernandez Gonzalez, C.; Martin Gonzalez, O.; Garcia Gonzalez, I.; Prieto Miranda, E.

    1995-01-01

    Human freeze dried serum was artificially contaminated with Flavobacterium sp. for studying the effects of gamma radiation of it. The radiobiological parameters of the contaminator were determined and the sterilization dose was set. The quality of the product irradiated at both, calculated sterilization dose (8.5 kGy) an another one about 25 kGy was determined. It was made according to: sterility testing, total proteins, pH enzymes (alanina-aminotransferase, aspartato-aminotransferase, alkaline phosphatase), protein electrophoresis, fast performance liquid chromatographic and effect on the cellular growth. From the latter was concluded that the calculated sterilization dose was adequate form keeping the biological properties and viability of the irradiated serum. Nevertheless, the dose of 25 k Gy was not adequate because of its dangerous effects on the cell culture

  9. Orchid flowers tolerance to gamma-radiation

    Energy Technology Data Exchange (ETDEWEB)

    Kikuchi, Olivia Kimiko E-mail: okikuchi@net.ipen.br

    2000-03-01

    Cut flowers are fresh goods that may be treated with fumigants such as methyl bromide to meet the needs of the quarantine requirements of importing countries. Irradiation is a non-chemical alternative to substitute the methyl bromide treatment of fresh products. In this research, different cut orchids were irradiated to examine their tolerance to gamma-rays. A 200 Gy dose did inhibit the Dendrobium palenopsis buds from opening, but did not cause visible damage to opened flowers. Doses of 800 and 1000 Gy were damaging because they provoked the flowers to drop from the stem. Cattleya irradiated with 750 Gy did not show any damage, and were therefore eligible for the radiation treatment. Cymbidium tolerated up to 300 Gy and above this dose dropped prematurely. On the other hand, Oncydium did not tolerate doses above 150 Gy.(author)

  10. Gamma Radiation-Induced Mutations in Soybeans

    International Nuclear Information System (INIS)

    Smutkupt, S.

    1998-01-01

    The main objective of soybean radiation experiments was to create genetic variability in soybeans of various cultivars, mutants and mutation-derived lines with the aim of producing superior breeding lines with resistance to soybean rust (Phakopsora pachyhrizi Syd.) It took altogether 12 generations over six years after gamma irradiation if soybean seeds to produce the best resistant line (81-1-038) which a variety could be developed from it. This Line 81-1-038 showed a very good specific resistance to soybean rust, Thai race 2 and moderately resistance to Thai race 1. In the rainy season of 1985, Line 81-1-038 out yielded S.J.4 (a mother line) by 868 kg/ha in a yield trail at Suwan Farm, Pak Chong, Nakorn Rajchasima. This soybean rust mutant was later named D oi Kham

  11. Influence of the temperature in the measurement of the gamma automatic probe Gamma Tracer; Influencia de la temperatura en la medicion de la sonda gamma automatica Gamma Tracer

    Energy Technology Data Exchange (ETDEWEB)

    Caveda R, C.A.; Dominguez L, O.; Alonso A, D. [CPHR, Calle 20 No. 4113 e/41 y 47, Playa, C.P. 11300, A.P. 6195, C.P. 10600 La Habana (Cuba); Montalvan E, A.; Fabelo B, O. [CIAC, Ave. Finlay Km 2 1/2, Rpto. Puerto Principe, Camaguey 70800 (Cuba)]. e-mail: caveda@cphr.edu.cu

    2006-07-01

    In the following work an analysis of the existent relationship among the measurement of the absorbed dose rate in air due to the environmental gamma radiation and the temperature, magnitudes measured to intervals of 10 minutes by the gamma probe Gamma Tracer located in the post of occident of the National Net of Environmental Radiological Surveillance (RNVRA), in the Center of Protection and Hygiene of the Radiations (CPHR) is made. For it its were analyzed near 100,000 measurements corresponding to the period 2004-2005. For a better processing and interpretation of the data, these were analyzed with one frequency time zone and monthly using the Gamma Red software to which was necessary to add it some options. Finally it was submitted the probe to a heating process inside a stove. The results of the carried out experiments confirmed that the absorbed dose rate in air due to the environmental gamma radiation depends potentially of the probe temperature in the range of environmental temperature to which is subjected daily the same one. (Author)

  12. Absolute exposure determination of cobalt-60 gamma radiation

    International Nuclear Information System (INIS)

    Ahmad, S.S.; Ali, A.; Orfi, S.D.

    1986-02-01

    The report describes the procedure for the determination of absolute exposure for Cobalt-60 gamma radiation. A graphite cavity chamber, nominal volume of 1 cm 3 , manufactured by Austrian Research Centre Seibersdorf has been used. The exposure rate at reference distance determined with the graphite chamber was compared with mean exposure rate measured with NPL-Therapy level X-ray exposure meter normalized to same date. An agreement of 0.39% was found between the two measuring systems, which seems to be very encouraging and quite satisfactory. (authors)

  13. Polyvinyl Alcohol-Lead Nitrate Paint for Gamma Radiation Installations

    International Nuclear Information System (INIS)

    EI-Ahdal, M.A.

    2007-01-01

    Dealing with gamma ray installations represents an important problem for radiation protection workers. Radiation shielding is used to avoid the risk resulting from these gamma sources. This study suggested the use of polyvinyl alcohol (PVA) solution that contains lend nitrate (with lead metal/PVA= 1.72) to lower the gamma radiation intensity and reduce its risk to workers. This can be achieved by painting the radiation shielding with this solution Temperature relief of the irradiated solution shows the degradation of the polymer content up to 50 degree C, which starts to crosslink increasing the protection capability of this solution

  14. Comparative study of Si diodes for gamma radiation dosimetry

    International Nuclear Information System (INIS)

    Pascoalino, Kelly Cristina da Silva

    2010-01-01

    In this work it is presented the comparative study of Si diodes response for gamma radiation dosimetry. The diodes investigated, grown by float zone (Fz) and magnetic Czochralski (MCz) techniques, were processed at the Physics Institute of Helsinki University in the framework of the research and development of rad-hard silicon devices. To study the dosimetric response of these diodes they were connected in the photovoltaic mode to the input of a digital electrometer to measure the photocurrent signal due to the incidence of gamma-rays from a 60 Co source (Gammacell 220). The dosimetric parameter utilized to study the response of these devices was the charge, obtained trough the integration of the current signals, as a function of the absorbed dose. Studies of the influence of the pre-irradiation procedures on both sensitivity and stability of these diodes showed that the sensitivity decreased with the total absorbed dose but after a preirradiation of about 873 kGy they became more stable. Radiation damage effects eventually produced in the devices were monitored trough dynamic current and capacitance measurements after each irradiation step. Both samples also exhibited good response reproducibility, 2,21% (Fz) and 2,94% (MCz), obtained with 13 consecutive measurements of 15 kGy compared with the equivalent 195 kGy absorbed dose in one step of irradiation. It is important to note that these results are better than those obtained with routine polymethylmethacrylate (PMMA) dosimeters used in radiation processing dosimetry. (author)

  15. Measurement of the decay asymmetries of the radiative hyperon decays {xi}{sup 0}{yields}{lambda}{gamma} and {xi}{sup 0}{yields}{sigma}{sup 0}{gamma} with the NA48/1 experiment; Messung der Zerfallsasymmetrien der radiativen Hyperonzerfaelle {xi}{sup 0}{yields}{lambda}{gamma} und {xi}{sup 0}{yields}{sigma}{sup 0}{gamma} mit dem NA48/1-Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Behler, Matthias

    2007-07-01

    The radiative decay of a hyperon into a light hyperon and a photon allows to study the structure of the electroweak interaction of hadrons. For this purpose, the decay asymmetry is an appropriate observable. It describes the distribution of the daughter hyperon with respect to the polarization (vector)P of the mother hyperon by (dN)/(d cos({theta})){proportional_to}1+{alpha}vertical stroke (vector)P vertical stroke cos({theta}), where {theta} is the angle between (vector)P and the momentum of the daughter hyperon. The radiative decay {xi}{sup 0}{yields}{lambda}{sub {gamma}} is of particular interest since all calculations at quark level predict a positive decay asymmetry whereas two existing measurements result in a negative value of {alpha}{sub {xi}{sup 0}{yields}{lambda}{sub {gamma}}}=-0.73{+-}0.17. The goal of the analysis presented here was to verify these results and to improve the accuracy of the decay asymmetry measurement. In addition, the decay asymmetry of the similar decay {xi}{sup 0}{yields}{sigma}{sup 0}{sub {gamma}} was measured, and the well-known decay {xi}{sup 0}{yields}{lambda}{pi}{sup 0} was used to test the analysis strategy. During the data taking period in 2002, the NA48/1 experiment at CERN was searching for rare K{sub S} and hyperon decays. The collected data represents the world's largest sample of {xi}{sup 0} decays. From this sample, about 52,000 {xi}{sup 0}{yields}{lambda}{sub {gamma}} decays, 15,000 {xi}{sup 0}{yields}{sigma}{sup 0}{sub {gamma}} decays and 4 mill. {xi}{sup 0}{yields}{lambda}{pi}{sup 0} decays with small background were extracted as well as the corresponding anti {xi} decays. The available anti {xi} samples amount about one tenth of the {xi}{sup 0} samples. The measurement of the decay asymmetries was based on the comparison between data and a detailed Monte Carlo simulation, giving the following results: {alpha}{sub {xi}{sup 0}{yields}{lambda}{sub {gamma}}}=-0.701 {+-} 0.019{sub stat}{+-} 0.064{sub sys}, {alpha

  16. Gamma-ray emission profile measurements during JET ICRH discharges

    Energy Technology Data Exchange (ETDEWEB)

    Jarvis, O N; Marcus, F B; Sadler, G; Van Belle, P [Commission of the European Communities, Abingdon (United Kingdom). JET Joint Undertaking; Howarth, P J.A. [Birmingham Univ. (United Kingdom); Adams, J M; Bond, D S [UKAEA Harwell Lab. (United Kingdom). Energy Technology Div.

    1994-07-01

    Gamma-ray emission from plasma-impurity reactions caused by minority ICRH accelerating fuel ions to MeV energies has been measured using the JET neutron profile monitor. A successful data analysis technique has been used to isolate the RF-induced gamma-ray emission that was detected, enabling profiles of gamma-ray emission to be obtained. The 2-d gamma-ray emission profiles show that virtually all the radiation originates from the low field side of the RF resonance layer, as expected from RF-induced pitch angle diffusion. The emission profiles indicate the presence of a small population of resonant {sup 3}He ions that possess orbits lying near the passing-trapped boundary. 6 refs., 4 figs.

  17. Effects of gamma radiation on commercial operational amplifiers

    International Nuclear Information System (INIS)

    Claro, Luiz H.; Santos, Jose A. dos

    2009-01-01

    The operational amplifiers are widely used in nuclear instrumentation. Their applications span the signal conditioning circuits, analog instrumentation, amplifiers, converters, oscillators and others. If an operational amplifier is used to work in a radiation environment, the device suffers degradation in its performance leading to the bad work in the systems. Some of these devices are designed as rad-hard components and therefore the effects of radiation damage are minimized, however its main disadvantage is the high cost and difficult to find in the market. As an alternative one can use the conventional electronic components available in the market and named COTS (Commercially Available Off-The-Shelf) but they must be tested under a radiation environment. In this work the effect of the radiation damage is studied in two typical operational amplifiers. Some electric parameters of these devices were measured for different gamma radiation doses and they were working at different input signal frequencies. A 60 Co isotopic radiation source was used and the results show that there is a certain degradation of the device depending on the radiation absorbed dose. (author)

  18. Luminescent polymethyl methacrylate modified by gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Morais, Guilherme F. [Faculdade de Tecnologia de Sao Paulo (FATEC-ZL), Sao Paulo, SP (Brazil); Forster, Pedro L.; Marchini, Leonardo G.; Lugao, Ademar B.; Parra, Duclerc F., E-mail: dfparra@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    Thin films of PMMA (polymethyl methacrylate) doped with luminescent complexes have been studied and developed for applications in advanced technologies. The problem of stability of these films is focused in this study. Films stabilization by reaction with fluorinated monomers is a recent study that aims to increase its luminescence properties for long time. The films were prepared by dilution of PMMA in chloroform with addition of europium complex, at proportion of 5% by weight of polymer. The luminescent polymer films were obtained by casting. Thin layer slides of the film were separated in three parts. One was reacted with fluorinated monomers (C{sub 2}F{sub 4}) in closed reactor for 48 hours. A second part was reacted with C{sub 2}F{sub 4} after irradiation in gamma source at 5 kGy in simultaneous process. The last part was used as obtained. The luminescent polymer matrices were characterized using the techniques of infrared (FTIR) and thermogravimetry (TGA/DTG). Samples of the films were, in presence of fluorine monomers, exposed to ionizing radiation in dose of 5 kGy, for react with monomers in the doped polymer surface. In this case the effects of radiation were evaluated on the luminescent films. (author)

  19. Luminescent polymethyl methacrylate modified by gamma radiation

    International Nuclear Information System (INIS)

    Morais, Guilherme F.; Forster, Pedro L.; Marchini, Leonardo G.; Lugao, Ademar B.; Parra, Duclerc F.

    2011-01-01

    Thin films of PMMA (polymethyl methacrylate) doped with luminescent complexes have been studied and developed for applications in advanced technologies. The problem of stability of these films is focused in this study. Films stabilization by reaction with fluorinated monomers is a recent study that aims to increase its luminescence properties for long time. The films were prepared by dilution of PMMA in chloroform with addition of europium complex, at proportion of 5% by weight of polymer. The luminescent polymer films were obtained by casting. Thin layer slides of the film were separated in three parts. One was reacted with fluorinated monomers (C 2 F 4 ) in closed reactor for 48 hours. A second part was reacted with C 2 F 4 after irradiation in gamma source at 5 kGy in simultaneous process. The last part was used as obtained. The luminescent polymer matrices were characterized using the techniques of infrared (FTIR) and thermogravimetry (TGA/DTG). Samples of the films were, in presence of fluorine monomers, exposed to ionizing radiation in dose of 5 kGy, for react with monomers in the doped polymer surface. In this case the effects of radiation were evaluated on the luminescent films. (author)

  20. Decontamination of biological ferment by gamma radiation

    International Nuclear Information System (INIS)

    Sabundjian, Ingrid T.; Salum, Debora C.; Silva, Priscila V.; Furgeri, Camilo; Duarte, Renato; Villavicencio, Anna Lucia C.H.

    2007-01-01

    Biological ferment is a product obtained from pure yeast (Saccharomyces cerevisiae) culture by a suitable technological process and employed to increase the size and porosity of the baker's products. Foods containing high microorganisms count indicate that Good Manufacturing Practices were not applied. The aim of this study was to observe the viability of Dry Biological Ferment after the radiation process using different doses of 60 Co gamma rays and different storage times. Dry baker's yeast Saccharomyces cerevisiae samples were purchased from a local supermarket in Sao Paulo (Brazil) and irradiated at IPEN in a Gammacell source at 0.5, 1.0, 2.0 and 3.0 kGy doses (dose-rate of 3.51 kGy/h) at room temperature (25 deg C). The fluorescent method was performed to observe the viability of yeast cells. The viability decrease with the increase of the radiation dose, as shown: the amount of the viable cell found in the non-irradiated samples (control) at 0 day was 87.2%; 30 days 67.7%; 60 days 77.4% and 90 days 60.1%. With 1.0 kGy at 0 day was 61.4%; 30 days 22.7%; 60 days 56.9% and 90 days 24.2%. With 3.0 kGy at 0 day was 57.00%; at the next periods the most of the cells become not viable. (author)

  1. Measurement of Relative Biological Effectiveness (RBE) for the Radiation Beam from Neutron Source Reactor YAYOI -Comparisons with Cyclotron Neutron and 60Co Gamma Ray-

    OpenAIRE

    HIROAKI, WAKABAYASHI; SHOZO, SUZUKI; AKIRA, ITO; Nuclear Engineering Research Laboratory, Faculty of Engineering, the University of Tokyo; Institute of Medical Science, the University of Tokyo; Institute of Medical Science, the University of Tokyo

    1983-01-01

    Radiation biology and/or therapy research and development for a research reactor beam need specific RBEs of neutrons as well as of specific reactions. RBEs for reactor beams measured in situ condition are interesting because actual radiation effects on each biological system are different depending on detailed conditions of irradiation. A small powered research reactor (Fast Neutron Source Reactor: YAYOI) was examined here as a neutron beam source for obtaining survival curves in a manner usu...

  2. Gamma radiation and gamma ray protection factors of ships in various situations of radioactive fall-out

    International Nuclear Information System (INIS)

    Brehm, E.H.; Holst, T.

    1975-01-01

    In this report the development of methods of evaluating gamma ray protection factors (GSF) of ships for various situations of radioactive fall-out is described. The joining calculations of gamma ray protection factors are performed by the newly developed computer procedure GASUFA. These protection factors determine - in connection with a measured gamma radiation dose at a given detector point - the gamma radiation in different compartments of the ships. The computer program GASUFA is able to perform calculations considering the dependence of energy, place and time for the following situations: - the ship is under a radioactive cloud without fall-out; - the ship is under a radioactive cloud with fall-out; - the ship is contaminated by radioactive fall-out; - the clean or decontaminated ship is going through a zone, which is contaminated by radioactive fall-out; - the ship and the surrounding water surface are contaminated by radioactive fall-out. (orig.) [de

  3. Characterization of hydrothermal green quartz produced by gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Enokihara, Cyro T.; Rela, Paulo R., E-mail: cteiti@ipen.br, E-mail: prela06@yahoo.com.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Schultz-Güttler, Rainer A., E-mail: rainersgut@gmail.com [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Instituto de Geociencias

    2015-07-01

    A specific variety of quartz showing a green color in nature or induced artificially by radiation gamma ({sup 60}Co) is quite rare. Only two occurrences are known today, where this type of quartz can be found: Canada, at the Thunder Bay Amethyst Mine, Ontario and Brazil, at widely scattered geode occurrences along a 600 km stretch from Quarai at Brazils southern most tip to Uberlandia in Minas Gerais. These two occurrences have been formed by strong hydrothermal activities.That way much quartz crystals showed a very fast growth history facilitating the formation of growth defects (twinning, small angle tilting, mosaic growth, striations) and the uptake of water in form of micro inclusions, molecular water, silanol (Si-OH) and OH. In the present work the material analyzed is from hydrothermal regimes found in intrusions of basaltic rocks located in the Rio Grande do Sul state. To characterize these materials, colored green by gamma rays, analyses by ICP, electron microscopy, water loss techniques and UV-VIS or NIR-FTIR spectroscopic measurements have been made. Silanol complexes are formed, which by radiation due to gamma rays form the color center NBOHC (Non-bonding Oxygen Hole Center), showing absorption between 590 to 620 nm, responsible for the green color. The water content with up to 3200 ppm by weight exceeds the amount of charge balancing cations (Fe, Al, Li). There is no correlation between water content and cations as in other color varieties. (author)

  4. Evaluation of optical fibres as gamma radiation dosimeter

    International Nuclear Information System (INIS)

    Bohra, Dinesh; Chaudhary, H.S.; Panwar, Lalit; Vaijapurkar, S.G.; Bhatnagar, P.K.; Dasgupta, K.

    2005-01-01

    Semiconductor base gamma and neutron sensors are the fastest and popular dosimeters and are in competition with Thermoluminescence (TL) and Radio photoluminescence (RPL) dosimeters. All over the world armed forces require a dosimeter which records cumulative doses of ionizing radiations from mcGy to 10 Gy and is readable repeatedly without loss of dose information. TL dosimeters do not meet the criteria and RPL dosimeter meet the expectations and are in use by armed forces. Technologists have used laser as an excitation source to stimulate the glass and have achieved success in recording gamma doses of occupational/accidental span (mcGy to 10 Gy). However synthesizing RPL glass batches with exactly same characteristics predoses is a difficult task. Silicon base phosphorous doped step index multimode optical fibre can be made in a significant quantity and large number of dosimeters from it can be achieved with uniform predose. The radiation induced transmission loss gives a measure of gamma dose which is cumulative, readable repeatedly without loss of information. Assorted composition, core dia optical fibres have been synthesized and evaluated for dose linearity, dose rate independence, fading, length optimization. Here in is described some results of recent experiments and sensitivities achieved. (author)

  5. Current trends in gamma radiation detection for radiological emergency response

    Science.gov (United States)

    Mukhopadhyay, Sanjoy; Guss, Paul; Maurer, Richard

    2011-09-01

    Passive and active detection of gamma rays from shielded radioactive materials, including special nuclear materials, is an important task for any radiological emergency response organization. This article reports on the current trends and status of gamma radiation detection objectives and measurement techniques as applied to nonproliferation and radiological emergencies. In recent years, since the establishment of the Domestic Nuclear Detection Office by the Department of Homeland Security, a tremendous amount of progress has been made in detection materials (scintillators, semiconductors), imaging techniques (Compton imaging, use of active masking and hybrid imaging), data acquisition systems with digital signal processing, field programmable gate arrays and embedded isotopic analysis software (viz. gamma detector response and analysis software [GADRAS]1), fast template matching, and data fusion (merging radiological data with geo-referenced maps, digital imagery to provide better situational awareness). In this stride to progress, a significant amount of inter-disciplinary research and development has taken place-techniques and spin-offs from medical science (such as x-ray radiography and tomography), materials engineering (systematic planned studies on scintillators to optimize several qualities of a good scintillator, nanoparticle applications, quantum dots, and photonic crystals, just to name a few). No trend analysis of radiation detection systems would be complete without mentioning the unprecedented strategic position taken by the National Nuclear Security Administration (NNSA) to deter, detect, and interdict illicit trafficking in nuclear and other radioactive materials across international borders and through the global maritime transportation-the so-called second line of defense.

  6. Radiation detection and measurement

    International Nuclear Information System (INIS)

    Knoll, G.F.

    1979-01-01

    The book is a complete, clear and up-to-date text that provides a basic review of instruments and methods of ionizing radiation. The text covers detailed discussion of all detector types introductory discussions of radiation sources, interactions, and counting statistics functional analysis of the electronics and pulse processing aspects of radiation detectors in instrumentation systems and consideration of shielding and background potentially vital in low-level counting. A total of 350 figures and approximately 900 references to current scientific literature is included. The book is largely intended as a textbook for a junior/senior or first-year graduate course in nuclear instrumentation and radiation measurements

  7. Exposure of luminous marine bacteria to low-dose gamma-radiation.

    Science.gov (United States)

    Kudryasheva, N S; Petrova, A S; Dementyev, D V; Bondar, A A

    2017-04-01

    The study addresses biological effects of low-dose gamma-radiation. Radioactive 137 Cs-containing particles were used as model sources of gamma-radiation. Luminous marine bacterium Photobacterium phosphoreum was used as a bioassay with the bioluminescent intensity as the physiological parameter tested. To investigate the sensitivity of the bacteria to the low-dose gamma-radiation exposure (≤250 mGy), the irradiation conditions were varied as follows: bioluminescence intensity was measured at 5, 10, and 20°С for 175, 100, and 47 h, respectively, at different dose rates (up to 4100 μGy/h). There was no noticeable effect of gamma-radiation at 5 and 10°С, while the 20°С exposure revealed authentic bioluminescence inhibition. The 20°С results of gamma-radiation exposure were compared to those for low-dose alpha- and beta-radiation exposures studied previously under comparable experimental conditions. In contrast to ionizing radiation of alpha and beta types, gamma-emission did not initiate bacterial bioluminescence activation (adaptive response). As with alpha- and beta-radiation, gamma-emission did not demonstrate monotonic dose-effect dependencies; the bioluminescence inhibition efficiency was found to be related to the exposure time, while no dose rate dependence was found. The sequence analysis of 16S ribosomal RNA gene did not reveal a mutagenic effect of low-dose gamma radiation. The exposure time that caused 50% bioluminescence inhibition was suggested as a test parameter for radiotoxicity evaluation under conditions of chronic low-dose gamma irradiation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Effect of gamma-radiation on a water-insoluble arabinoxylan

    International Nuclear Information System (INIS)

    Ebringerová, A.; Pružinec, J.; Kačuráková, M.; Hromádková, Z.

    1989-01-01

    The effect of gamma radiation on a water-insoluble L-arabino-D-xylan has been studied by functional group and structural analysis using chemical methods and IR spectroscopy, by sugar composition analysis, and by viscosity measurements. The gamma irradiation has been shown to modify both sugar components of the arabinoxylan, accompanied by cleavage of the glycosidic linkages, depolymerization, and sugar decomposition, depending on the applied radiation dose, thus increasing the molecular and chemical heterogeneity of the polysaccharide. (author)

  9. Spectroscopic Study of Radiation around the Leksell Gamma Knife for Room Shielding Applications

    OpenAIRE

    Hubert, Alexis

    2017-01-01

    Any center planning to install a Gamma Knife radiosurgery unit has to provide for an efficient shielding of the treatment room, to protect the patient, the staff and the public, against undesired radiation. The shielding barrier design is controlled by national and international recommendations; the reference documents for gamma ray radiotherapy facilities are the National Council on Radiation Protection and Measurements (NCRP) reports 49 and 151. However, some facts highlighted in this thesi...

  10. Prompt Gamma Radiation from Fragments in the Thermal Fission of 235U

    International Nuclear Information System (INIS)

    Albinsson, H.; Lindow, L.

    1970-06-01

    Measurements were made on the gamma radiation emitted from fission fragments in slow neutron induced fission of 235 U. The fragments were detected with solid state detectors of the surface barrier type and the gamma radiation with a Nal(Tl) scintillator. Mass selection was used so that the gamma radiation could be measured as a function of fragment mass. Time discrimination between the fission gammas and the prompt neutrons released in the fission process was employed to reduce the background. The gamma radiation emitted during different time intervals after the fission event was studied with the help of a collimator, the position of which was changed along the path of the fission fragments. In this way a decay curve was obtained from which the life-time of one of the gamma-emitting states could be estimated. The relative yield of the gamma-rays was determined as a function of mass for different gamma-ray energy portions and two specific time intervals after the fission events. Comparisons were made with data obtained from 252 Cf-fission. Attention is drawn to some features which seem to be the same in 235 U and 252 Cf-fission

  11. Prompt Gamma Radiation from Fragments in the Thermal Fission of {sup 235}U

    Energy Technology Data Exchange (ETDEWEB)

    Albinsson, H [Chalmers Univ. of Technology, Goteborg (Sweden); Lindow, L [AB Atomenergi, Nykoeping (Sweden)

    1970-06-15

    Measurements were made on the gamma radiation emitted from fission fragments in slow neutron induced fission of {sup 235}U. The fragments were detected with solid state detectors of the surface barrier type and the gamma radiation with a Nal(Tl) scintillator. Mass selection was used so that the gamma radiation could be measured as a function of fragment mass. Time discrimination between the fission gammas and the prompt neutrons released in the fission process was employed to reduce the background. The gamma radiation emitted during different time intervals after the fission event was studied with the help of a collimator, the position of which was changed along the path of the fission fragments. In this way a decay curve was obtained from which the life-time of one of the gamma-emitting states could be estimated. The relative yield of the gamma-rays was determined as a function of mass for different gamma-ray energy portions and two specific time intervals after the fission events. Comparisons were made with data obtained from {sup 252} Cf-fission. Attention is drawn to some features which seem to be the same in {sup 235}U and {sup 252} Cf-fission.

  12. Observations of nesting avifauna under gamma-radiation exposure

    International Nuclear Information System (INIS)

    Buech, R.R.

    1977-01-01

    An opportunity arose to observe the nesting success of birds (up to the time of fledging) when the Enterprise Forest Radiation Facility was established for a study of the effects of gamma radiation on the flora and fauna of northern forest communities. The results of these observations on the fate of the nest occupants in relation to radiation exposure are presented

  13. Variation of the optical energy gap with {gamma}-radiation and thickness in Bi-thin films

    Energy Technology Data Exchange (ETDEWEB)

    Al-Houty, L.; Kassem, M.E.; Abdel Kader, H.I. [Qatar Univ., Doha (Qatar). Dept. of Physics

    1995-02-01

    The effect of {gamma}-radiation and thickness on the optical energy gap of Bi-thin films has been investigated by measuring their optical absorbance. The measurements were carried out on thermally evaporated films having thicknesses in the range 5-20 nm. Different {gamma}-radiation doses were used ranging from 0-300 Mrad. The optical energy gap as well as the absorption coefficient were found to be {gamma}-dose dependent. (author).

  14. Calibration and study of the measurement capabilities of real-time gamma spectrometry equipment developed for the renewal of the network of stations automatic monitoring environmental radiation of the Generalitat of Catalunya

    International Nuclear Information System (INIS)

    Casanovas, R.; Prieto, E.; Salvado, M.

    2014-01-01

    The renewal of the automatic environmental radiation surveillance network of the Generalitat of Catalunya has been carried out through the development and implementation of gamma-spectrometry-based equipment. the monitors use scintillation crystals, either Na(TI) or LaBr 3 (Ce) and currently, there are 3 types of equipment water radioactivity monitors, aerosols on a particulate filter monitors and direct measurement monitors. In this paper, we expose the basic features of its operation, the details of their calibration and the minimum detectable activity concentration for some isotopes. (Author)

  15. Development of defects in the structure of PIN dosimetry diodes exposed to gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Sopko, V. [Hospital Na Bulovce, Department of Radiological Physics, Budinova 2, CZ-18081 Prague 8 (Czech Republic); Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, CZ 12800 Prague 2 (Czech Republic); Sopko, B., E-mail: bruno.sopko@cern.ch [Department of Physics, Faculty of Mechanical Engineering, Czech Technical University in Prague, Technicka 4, CZ 16000 Prague 6 (Czech Republic); Faculty of Production Technology and Management, J. E. Purkyně Univerzity in Ústí nad Labem, Na Okraji 1001, 400 01 Ústí nad Labem (Czech Republic); Chren, D. [Department of Physics, Faculty of Mechanical Engineering, Czech Technical University in Prague, Technicka 4, CZ 16000 Prague 6 (Czech Republic); Dammer, J. [Hospital Na Bulovce, Department of Radiological Physics, Budinova 2, CZ-18081 Prague 8 (Czech Republic); Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, CZ 12800 Prague 2 (Czech Republic); Charles University in Prague, First Faculty of Medicine, Salmovská 1,CZ-12000 Prague 2 (Czech Republic)

    2013-12-01

    Studies of radiation induced defects continue to be relevant as they find an ever greater application due to the increasing radiation doses to which semiconductor detectors are exposed. Efforts of figuring out the changes due to high radiation doses provide the fundamental motivation for this type of experiments. The PIN diode is described, and a developmental disorder caused thereto by 60Co source gamma quanta ranging from 100 kGy to 1 MGy. The calibration curve shows the effect of disturbances on the volt-ampere characteristics as a function of the dose of gamma radiation. The results are compared with earlier published data. Highlights: •We have studied Si PIN diode dosimeters irradiated by gamma. •We measured DLTS spectra and calculated energy traps caused by gamma irradiation. •Increasing dose caused creation of new traps and disappearance of others.

  16. On the omnipresent background gamma radiation of the continuous spectrum

    Energy Technology Data Exchange (ETDEWEB)

    Banjanac, R.; Maletić, D.; Joković, D., E-mail: yokovic@ipb.ac.rs; Veselinović, N.; Dragić, A.; Udovičić, V.; Aničin, I.

    2014-05-01

    The background spectrum of a germanium detector, shielded from the radiations arriving from the lower and open for the radiations arriving from the upper hemisphere, is studied by means of absorption measurements, both in a ground level and in an underground laboratory. The low-energy continuous portion of this background spectrum that peaks at around 100 keV, which is its most intense component, is found to be of very similar shape at the two locations. It is established that it is mostly due to the radiations of the real continuous spectrum, which is quite similar to the instrumental one. The intensity of this radiation is in our cases estimated to about 8000 photons/(m{sup 2}s·2π·srad) in the ground level laboratory, and to about 5000 photons/(m{sup 2}s·2π·srad) in the underground laboratory, at the depth of 25 m.w.e. Simulations by GEANT4 and CORSIKA demonstrate that this radiation is predominantly of terrestrial origin, due to environmental gamma radiations scattered off the materials that surround the detector (the “skyshine radiation”), and to a far less extent to cosmic rays of degraded energy. - Highlights: • We studied the low-energy part of continuous background spectra of germanium detectors. • The study was performed at the ground level and at the shallow underground sites. • The instrumental spectrum is due to radiations of the similar continuous spectrum. • The low-energy radiation is of both terrestrial and cosmic-ray origin. • In our study, we find that this radiation is of predominantly terrestrial origin.

  17. Gamma Radiation-Induced Template Polymerization Technique

    International Nuclear Information System (INIS)

    Siyam, T.

    2005-01-01

    Gamma radiation induced copolymerization of acrylamide sodiumacrylate (AM-AANa) in the presence and absence of the polymer additive was studied at low monomer concentration(1.4M/l). The results showed that the exponents of the dose rate for the polymerization rate was found to be 1.3 and 1.4 in the absence and in the presence of the polymer additive respectively. The molecular weight of the formed polymer increased by addition of the polymer to the system. In the presence of the polymer the comonomers polymerize on the added polymer. In the absence of the added polymer the comonomers polymerize according to the copolymerization process at the initial stage of the copolymerization. While at high conversion the residual comonomers polymerize on the formed macromolecular chains of the produced polymer. These studies showed that the copolymerization in the presence of added polymer is completely template copolymerization while in the absence of the polymer the copolymerization process is only template process with a high conversion

  18. Gamma radiation sterilized amnion: use in ophthalmology

    International Nuclear Information System (INIS)

    Martinez P, M. E.; Leon T, Y.; Vazquez M, L.

    2010-10-01

    Amnion processed at the Radio sterilized Tissue Bank at the National Institute of Nuclear Research, sterilized with 60 Co gamma radiation, have been used in Mexico since 2005 either as a graft to replace the damaged ocular surface, or as a patch to prevent unwanted inflammatory reactions. Patients from the Hospital General de Mexico (HGM) and Instituto Mexicano del Seguro Social (IMSS), suffering diverse pathologies such as keratoconjunctivitis; recurrent pterygium associated with symblepharon; corneal neuro trophic ulcers, chemical and thermal burns, and corneal thinning s, had been successfully treated with irradiated amnion. In the HGM, a clinical prospective study on lesions of the ocular surface of 17 eyes from 15 patients, affected with the above mentioned pathologies, was successful in 88.2%. The results have proven to be excellent as much for cosmetic purposes as for functional ones. Without the treatment, the patients could have suffered a healing after-effect or loss of sight. At IMSS, a controlled clinical randomized trial with 108 eyes from 100 patients, affected with primary nasal pterygium, was performed in 2009. These eyes were treated with radio sterilized amnion and intraoperative mitomycin C to prevent recurrence after excision of the primary pterygium. The preliminary results do not shown adverse reaction, inflammation and pain were significantly reduced radio sterilized amnion also offer security because they do no express antigens HLA-A, B or Dr and the sterile irradiated tissue do not provoke rejection or transmit an infective disease. (Author)

  19. Gamma radiation sterilized amnion: use in ophthalmology

    Energy Technology Data Exchange (ETDEWEB)

    Martinez P, M. E. [ININ, Carretera Mexico-Toluca s/n, Ocoyoacac 52750, Estado de Mexico (Mexico); Leon T, Y. [Hospital General Regional 220, IMSS, Paseo Tollocan No. 620, Col. Vertice, Toluca 50150, Estado de Mexico (Mexico); Vazquez M, L., E-mail: esther.martinez@inin.gob.m [Hospital General de Mexico, Dr. Balmis 148, Col. Doctores, 06720 Mexico D. F. (Mexico)

    2010-10-15

    Amnion processed at the Radio sterilized Tissue Bank at the National Institute of Nuclear Research, sterilized with {sup 60}Co gamma radiation, have been used in Mexico since 2005 either as a graft to replace the damaged ocular surface, or as a patch to prevent unwanted inflammatory reactions. Patients from the Hospital General de Mexico (HGM) and Instituto Mexicano del Seguro Social (IMSS), suffering diverse pathologies such as keratoconjunctivitis; recurrent pterygium associated with symblepharon; corneal neuro trophic ulcers, chemical and thermal burns, and corneal thinning s, had been successfully treated with irradiated amnion. In the HGM, a clinical prospective study on lesions of the ocular surface of 17 eyes from 15 patients, affected with the above mentioned pathologies, was successful in 88.2%. The results have proven to be excellent as much for cosmetic purposes as for functional ones. Without the treatment, the patients could have suffered a healing after-effect or loss of sight. At IMSS, a controlled clinical randomized trial with 108 eyes from 100 patients, affected with primary nasal pterygium, was performed in 2009. These eyes were treated with radio sterilized amnion and intraoperative mitomycin C to prevent recurrence after excision of the primary pterygium. The preliminary results do not shown adverse reaction, inflammation and pain were significantly reduced radio sterilized amnion also offer security because they do no express antigens HLA-A, B or Dr and the sterile irradiated tissue do not provoke rejection or transmit an infective disease. (Author)

  20. Effect of gamma radiation and ethylene oxide on neomycin sulphate

    International Nuclear Information System (INIS)

    Gopal, N.G.S.; Rajagopalan, S.

    1981-01-01

    Neomycin is affected by ethylene oxide but not by gamma radiation (2.75 Mrad). Differential refractometry is more advantageous in quantitating neomycin A, B and C than is the ninhydrin method. (Auth.)

  1. Inactivation of rabies diagnostic reagents by gamma radiation

    International Nuclear Information System (INIS)

    Gamble, W.C.; Chappell, W.A.; George, E.H.

    1980-01-01

    Treatment of CVS-11 rabies adsorbing suspensions and street rabies infected mouse brains with gamma radiation resulted in inactivated reagents that are safer to distribute and use. These irradiated reagents were as sensitive and reactive as the nonirradiated control reagents

  2. Mango conservation, Mangifera indica L., haden variety by gamma radiation

    International Nuclear Information System (INIS)

    Domarco, R.E.

    1989-02-01

    This paper evaluates the chemical characteristics and the mangoes sensorial quality after treatments with different doses of gamma radiation and during a period of storage, with constant conditions of temperature and relative humidity. (author)

  3. Nature of gamma rays background radiation in new and old buildings of Qatar University

    International Nuclear Information System (INIS)

    Al-Houty, L.; Abou-Leila, H.; El-Kameesy, S.

    1987-01-01

    Measurements and analysis of gamma-background radiation spectrum in four different places of Qatar University campus were performed at the energy range 10 keV-3 MeV using hyper pure Ge-detector. The dependence of the detector absolute photopeak efficiency on gamma-ray energies was determined and correction of the data for that was also done. The absorbed dose for each gamma line was calculated and an estimation of the total absorbed dose for the detected gamma lines in the four different places was obtained. Comparison with other results was also performed

  4. Feasibility Study on Fiber-optic Radiation Sensor for Remote Gamma-ray Spectroscopy

    International Nuclear Information System (INIS)

    Jeon, Hyesu; Jang, Kyoung Won; Shin, Sang Hun and others

    2014-01-01

    In this study, we fabricated a fiber-optic radiation sensor using an optical fiber and various scintillators. To select an adequate inorganic scintillator for the sensing probe of fiber-optic radiation sensor, 5 types of scintillators were evaluated. The spectra of gamma-rays emitted from a Na-22 radiation source were measured by using the manufactured sensors. As a result, the BGO was suitable for the sensing probe of fiber-optic radiation sensor due to its high scintillation output and exact photoelectric peak for the gamma-ray energy. The basic principle of radiation detection is to detect the signals caused by interactions between radiations and materials. There are various types of radiation detectors depending on types of radiation to be detected and physical quantities to be measured. As one of the radiation detectors, a fiber-optic radiation sensor using a scintillator and an optical fiber has two advantages such as no space restraint and remote sensing. Moreover, in nuclear environments, this kind of sensor has immunities for electromagnetic field, temperature, and pressure. Thus, the fiber-optic radiation sensor can be used in various fields including nondestructive inspection, radioactive waste management, nuclear safety, radiodiagnosis and radiation therapy. As a fundamental study of the fiber-optic radiation sensor for remote gamma-ray spectroscopy, in this study, we fabricated a fiber-optic radiation sensor using an optical fiber and various scintillators. To select an adequate inorganic scintillator for the sensing probe of fiber-optic radiation sensor, 5 types of scintillators were evaluated. The spectra of gamma-rays emitted from a Na-22 radiation source were measured by using the manufactured sensors

  5. Gamma radiation processing dosimetry with commercial silicon diodes

    International Nuclear Information System (INIS)

    Ferreira, Danilo Cardenuto

    2009-01-01

    This work envisages the development of dosimeters based on Si diodes for gamma radiation dosimetry from 1 Gy up to 100 Gy. This dose range is frequently utilized in radiation processing of crystal modifications, polymers crosslinking and biological studies carried out in the Radiation Technology Center at IPEN-CNEN/SP. The dosimeter was constructed by a commercial SFH00206 (Siemens) Si diode, operating in a photovoltaic mode, whose electrical characteristics are suitable for this application. The current generated in the device by the Cobalt-60 gamma radiation from the Irradiators types I and II was registered with a digital electrometer and stored during the exposure time. In all measurements, the current signals of the diode registered as a function of the exposure time were very stable. Furthermore, the device photocurrent was linearly dependent on the dose rate within a range of 6.1x10 -2 Gy/min up to 1.9x10 2 Gy/min. The calibration curves of the dosimeters, e.g., the average charge registered as a function of the absorbed dose were obtained by the integration of the current signals as a function of the exposure time. The results showed a linear response of the dosimeter with a correlation coefficient better than 0.998 for total absorbed dose up to 120 Gy. Finally, due to the small experimental errors 5 % it was also possible to measure the transit dose due to the movement of the Cobalto- 60 radioactive sources in irradiation facilities used in this work. (author)

  6. Gamma radiation combined with cinnamon oil to maintain fish quality

    Science.gov (United States)

    Lyu, Fei; Zhang, Jing; Wei, Qianqian; Gao, Fei; Ding, Yuting; Liu, Shulai

    2017-12-01

    Effects of gamma radiation combined with cinnamon oil on quality of Northern Snakehead fish fillets were observed during storage at 4 °C. Fish fillets were treated with 1-5 kGy gamma radiation, 0.05-0.5% cinnamon oil or the combination of radiation and cinnamon oil. The antimicrobial activity increased with radiation dose and cinnamon oil concentration. During storage, the combination of 1 kGy radiation and 0.5% cinnamon oil displayed better inhibiting activities on aerobic plate counts, total volatile basic nitrogen, thiobarbituric acid reaction substances than 1 kGy radiation or 0.5% cinnamon oil used alone. Moreover, the combination could arrive at the similar inhibiting activities of cinnamon oil with higher concentration of 0.5% or radiation with higher dose of 5 kGy. Thus, the combination could decrease the radiation dose and cinnamon oil concentration without decreasing the effect of them on maintaining fish quality.

  7. Analysis of portable gamma flaw detectors concerning radiation hygiene

    International Nuclear Information System (INIS)

    Makarova, T.V.

    1982-01-01

    Design and shields of gamma flaw detectors as one of the main factors responsible for personnel dose were studied. The analysis was conducted using the results of radiation hygienic surveys of gamma flaw detection laboratories functioning constantly in Estonia. It is shown that recently the replacement of GUP apparatuses by flaw detectors of RID and ''Gamma-RID'' (types which have design and shielding advantages is observed. However personnel doses have not reduced considerably for the last 10 years. This fact is attributed to design disadvantages of the RID and ''Gamma-RID'' apparatuses the removing of which will give the decreasing of annual personnel dose by 80 %

  8. Gamma radiation from PSR B1055-52

    DEFF Research Database (Denmark)

    Thompson, D.J.; Bailes, M.; Bertsch, D.L.

    1999-01-01

    The telescopes on the Compton Gamma Ray Observatory (CGRO) have observed PSR B1055-52 a number of times between 1991 and 1998. From these data a more detailed picture of the gamma radiation from this source has been developed, showing several characteristics that distinguish this pulsar: the light...... curve is complex; there is no detectable unpulsed emission; the energy spectrum is hat, with no evidence of a sharp high-energy cutoff up to greater than 4 GeV. Comparisons of the gamma-ray data with observations at longer wavelengths show that no two of the known gamma-ray pulsars have quite the same...

  9. Propagation speed of {gamma}-radiation in air

    Energy Technology Data Exchange (ETDEWEB)

    Cavalcante, Jose T.P.D.; Silva, Paulo R.J.; Saitovitch, Henrique [Centro Brasileiro de Pesquisas Fisicas (CBPF), Rio de Janeiro, RJ (Brazil); Macedo Junior, Marcelo A.V. [Centro Federal de Educacao Tecnologica de Quimica de Nilopolis (CEFET), RJ (Brazil)

    2008-07-01

    To perform such measurements the availability of a gamma radiation source in which two {gamma}-rays are emitted simultaneously in opposite directions -as already used(5,6) as well as applied in the present case- turns out to be essential to the feasibility of the experiment, as far as no reflection techniques could be used. Such suitable source was the positron emitter {sup 22}Na placed in a metal container in which the positrons are stopped and annihilated when reacting with the medium electrons, in such way originating -as it is very well established from momentum/energy conservation laws(7)- two {gamma}-rays, energy 511 KeV each, both emitted simultaneously in opposite directions. In all these previous experiments were used photomultiplier detectors coupled to NaI(Tl) crystal scintillators, which have a good energy resolution but a deficient time resolution for such purposes. Presently, as an innovatively improvement, were used BaF{sub 2} and CsF crystal scintillators which display a much better time resolution. (author)

  10. A Comparison Of GADRAS Simulated And Measured Gamma Ray Spectra

    International Nuclear Information System (INIS)

    Jeffcoat, R.; Salaymeh, S.

    2010-01-01

    Gamma-ray radiation detection systems are continuously being developed and improved for detecting the presence of radioactive material and for identifying isotopes present. Gamma-ray spectra, from many different isotopes and in different types and thicknesses of attenuation material and matrixes, are needed to evaluate the performance of these devices. Recently, a test and evaluation exercise was performed by the Savannah River National Laboratory that required a large number of gamma-ray spectra. Simulated spectra were used for a major portion of the testing in order to provide a pool of data large enough for the results to be statistically significant. The test data set was comprised of two types of data, measured and simulated. The measured data were acquired with a hand-held Radioisotope Identification Device (RIID) and simulated spectra were created using Gamma Detector Response and Analysis Software (GADRAS, Mitchell and Mattingly, Sandia National Laboratory). GADRAS uses a one-dimensional discrete ordinate calculation to simulate gamma-ray spectra. The measured and simulated spectra have been analyzed and compared. This paper will discuss the results of the comparison and offer explanations for spectral differences.

  11. Dosimetry and Shielding of X and Gamma Radiation

    International Nuclear Information System (INIS)

    Oncescu, M.; Panaitescu, I.

    1992-01-01

    This book covers the following problems: 1. X and Gamma radiations, 2. Interaction of X-ray and gamma radiations with matter, 3. Interaction of electrons with matter, 4. Principles and basic concepts of dosimetry, 5. Ionization dosimetry, 6. Calorimetric chemical and photographic dosimetry, 7. Solid state dosimetry, 8. Computation of dosimetric quantities, 9. Dosimetry in radiation protection, 10. Shielding of X and gamma radiations. The authors, well-known Romanian experts in Radiation Physics and Engineering, gave an up-dated, complete and readable account of this subject matter. The analyses of physical principles and concepts, of materials and instruments and of computational methods and applications are all well balanced to meat the needs of a broad readership

  12. Standardization of test conditions for gamma camera performance measurement

    International Nuclear Information System (INIS)

    Jordan, K.

    1982-02-01

    The way of measuring gamma camera performance is to use point sources or flood sources in air, often in combination with bar phantoms. This method has nothing in common with the use of a camera in clinical practice. Particularly in the case of low energy emitters, like Tc-99m, the influence of scattered radiation over the performance of cameras is very high. The IEC document 'Characteristics and test conditions of radionuclide imaging devices' is discussed

  13. Assessment of terrestrial gamma radiation in Sudan

    International Nuclear Information System (INIS)

    Sam, A.K.; Ahamed, M.M.O.; El Khangi, F.A.; El Nigumi, Y.O.; Holm, E.

    1997-01-01

    Calculations of the external exposure due to γ radiation from the ground have been made from the results of the measurements of radionuclide activity concentrations in the soil at various locations in Sudan. The average exposure was found to be 45 nGy.h -1 , corresponding to the annual dose equivalent of 278 μSv.y -1 . With the exception of the Arkuri and Dumper areas in the western part of the country, the calculated exposure falls within the global wide range of outdoor radiation exposure given in the UNSCEAR publications. The nationwide average concentrations of 226 Ra, 238 U, 232 Th, 40 K and 137 Cs determined were 31.62, 20.11, 19.10, 280.29 and 4.12 Bq.kg -1 , respectively. This shows that there is little contamination due to fallout radioactivity at survey sites. (author)

  14. Dibasic calcium phosphate dihydrate, USP material compatibility with gamma radiation

    Science.gov (United States)

    Betancourt Quiles, Maritza

    Gamma radiation is a commonly used method to reduce the microbial bioburden in compatible materials when it is applied at appropriate dose levels. Gamma irradiation kills bacteria and mold by breaking down the organism’s DNA and inhibiting cell division. The purpose of this study is to determine the radiation dosage to be used to treat Dibasic Calcium Phosphate Dihydrate, USP (DCPD) and to evaluate its physicochemical effects if any, on this material. This material will be submitted to various doses of gamma radiation that were selected based on literature review and existing regulations that demonstrate that this method is effective to reduce or eliminate microbial bioburden in natural source and synthetic materials. Analytical testing was conducted to the DCPD exposed material in order to demonstrate that gamma radiation does not alter the physicochemical properties and material still acceptable for use in the manufacture of pharmaceutical products. The results obtained through this study were satisfactory and demonstrated that the gamma irradiation dosages from 5 to 30 kGy can be applied to DCPD without altering its physicochemical properties. These are supported by the Assay test data evaluation of lots tested before and after gamma irradiation implementation that show no significant statistical difference between irradiated and non irradiated assay results. The results of this study represent an achievement for the industry since they provide as an alternative the use of Gamma irradiation technology to control the microbial growth in DCPD.

  15. Gamma radiation effects on physical properties of parchment documents: Assessment of Dmax

    International Nuclear Information System (INIS)

    Nunes, Inês; Mesquita, Nuno; Cabo Verde, Sandra; João Trigo, Maria; Ferreira, Armando; Manuela Carolino, Maria; Portugal, António; Luísa Botelho, Maria

    2012-01-01

    Parchments are important documents that give testimony for History; therefore these materials should be respected and preserved. Considering incremental biodeterioration problems that have to be faced daily, the Archive of the University of Coimbra (AUC) is involved in different scientific projects in order to evaluate and determine new methods for document decontamination and preservation. The aim of this study was to evaluate gamma radiation effects on the colour and texture of the AUC parchment documents. The assessment of these effects was used to estimate the maximum gamma radiation dose (D max ) that could guarantee parchment documents′ decontamination treatment, without significant alteration of their physical properties. Parchment samples were exposed to gamma radiation doses ranging from 10 to 30 kGy. The texture and colour of samples were assessed before and after the irradiation procedure, using a texture analyser and an electronic colorimeter. Hardness and springiness were determined based on texture spectra. Lightness (L⁎), Chroma (C), greenness vs. redness (a*) and yellowness vs. blueness (b*) values were obtained from colorimetric measures. Results indicate no significant effects of gamma radiation on the texture and colour of parchment for the studied doses. - Highlights: ► Study on the effects of gamma radiation in parchment physical properties. ► Evaluation of the uniformity of parchment samples′ physical parameters. ► Proposal of a maximum gamma radiation dose for parchment decontamination treatment.

  16. Automation of scanning technique by gamma radiation

    International Nuclear Information System (INIS)

    Aamira, Yahya

    2011-01-01

    The gamma scan technique is a nuclear test allowing the analysis of the internal mechanical properties of distillation columns used in petrochemical industries. Such technique is performed manually. So we propose in this work to automate the gamma scan procedure test by using a PLC. In addition, supervision and data acquisition interfaces are proposed.

  17. Gamma radiation effect study in polycarbonate optical and mechanics properties

    International Nuclear Information System (INIS)

    Araujo, E.S. de.

    1991-02-01

    Polycarbonates (PC) are used in different industrial applications due to their excellent dielectric characteristics, impact resistance, and high temperature resistance. In some of these applications, the polycarbonates are exposed to gamma radiation which produces molecular scissions, causing changes in the polycarbonate properties. To estimate the radiation effects in the Durolon polycarbonate, samples were irradiated with 60 Co gamma rays with doses between 0,2 kGy and 300 kGy. The results obtained showed that the PC mechanical properties are not changed due to the gamma radiation. However the results showed an expressive variation in the yellowness index for doses above 1 kGy. The results showed that it is possible to use the gamma sterilization of PC in applications where the coloration of PC is not critical. (author). 21 refs, 25 figs, 3 tabs

  18. Assembly of gamma radiation detection with directivity properties

    International Nuclear Information System (INIS)

    Stoica, M.; Talpalariu, C.

    2016-01-01

    An assembly of gamma radiation detection with directivity properties and small size enables the development of portable equipment or robots specialized in finding and signaling radioactively contaminated areas in case of nuclear incidents or decommissioning of nuclear installations. Directivity characteristic of the assembly of gamma radiation detection is very important when aiming to build an equipment for searching radioactively contaminated areas. In order to obtain a suitable directivity characteristics in terms of detection of gamma rays, it was necessary to construct a lead collimator with a cylindrical shape. The detector, preamplifier and amplifier pulse were placed inside the collimator and pulse discriminator circuit and power source were placed beside the collimator, all being disposed within the housing cylindrical experimental. A PIN photodiode type was used as a detector of gamma radiation. (authors)

  19. Development of a novel gamma probe for detecting radiation direction

    Science.gov (United States)

    Pani, R.; Pellegrini, R.; Cinti, M. N.; Longo, M.; Donnarumma, R.; D'Alessio, A.; Borrazzo, C.; Pergola, A.; Ridolfi, S.; De Vincentis, G.

    2016-01-01

    Spatial localization of radioactive sources is currently a main issue interesting different fields, including nuclear industry, homeland security as well as medical imaging. It is currently achieved using different systems, but the development of technologies for detecting and characterizing radiation is becoming important especially in medical imaging. In this latter field, radiation detection probes have long been used to guide surgery, thanks to their ability to localize and quantify radiopharmaceutical uptake even deep in tissue. Radiolabelled colloid is injected into, or near to, the tumor and the surgeon uses a hand-held radiation detector, the gamma probe, to identify lymph nodes with radiopharmaceutical uptkake. The present work refers to a novel scintigraphic goniometric probe to identify gamma radiation and its direction. The probe incorporates several scintillation crystals joined together in a particular configuration to provide data related to the position of a gamma source. The main technical characteristics of the gamma locator prototype, i.e. sensitivity, spatial resolution and detection efficiency, are investigated. Moreover, the development of a specific procedure applied to the images permits to retrieve the source position with high precision with respect to the currently used gamma probes. The presented device shows a high sensitivity and efficiency to identify gamma radiation taking a short time (from 30 to 60 s). Even though it was designed for applications in radio-guided surgery, it could be used for other purposes, as for example homeland security.

  20. Development of a novel gamma probe for detecting radiation direction

    International Nuclear Information System (INIS)

    Pani, R.; Pellegrini, R.; Cinti, M.N.; Longo, M.; Donnarumma, R.; Borrazzo, C.; D'Alessio, A.; Pergola, A.; Ridolfi, S.; Vincentis, G. De

    2016-01-01

    Spatial localization of radioactive sources is currently a main issue interesting different fields, including nuclear industry, homeland security as well as medical imaging. It is currently achieved using different systems, but the development of technologies for detecting and characterizing radiation is becoming important especially in medical imaging. In this latter field, radiation detection probes have long been used to guide surgery, thanks to their ability to localize and quantify radiopharmaceutical uptake even deep in tissue. Radiolabelled colloid is injected into, or near to, the tumor and the surgeon uses a hand-held radiation detector, the gamma probe, to identify lymph nodes with radiopharmaceutical uptkake. The present work refers to a novel scintigraphic goniometric probe to identify gamma radiation and its direction. The probe incorporates several scintillation crystals joined together in a particular configuration to provide data related to the position of a gamma source. The main technical characteristics of the gamma locator prototype, i.e. sensitivity, spatial resolution and detection efficiency, are investigated. Moreover, the development of a specific procedure applied to the images permits to retrieve the source position with high precision with respect to the currently used gamma probes. The presented device shows a high sensitivity and efficiency to identify gamma radiation taking a short time (from 30 to 60 s). Even though it was designed for applications in radio-guided surgery, it could be used for other purposes, as for example homeland security

  1. Spatial and energy distributions of skyshine neutron and gamma radiation from nuclear reactors on the ground-air boundary

    Energy Technology Data Exchange (ETDEWEB)

    Orlov, Y.; Netecha, M.E.; Vasiliev, A.P.; Avaev, V.N.; Vasiliev, G.A. [Research and Development Institute of Power Engineering, Moscow (Russian Federation); Zelensky, D.I.; Istomin, Y.L.; Cherepnin, Y.S. [Institute of Atomic Energy of the National Nuclear Center of the Republic of Kazakhstan, Semipalatinsk-21 (Kazakhstan); Nomura, Y. [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2000-03-01

    A set of measurements on skyshine radiation was conducted at two special research reactors. A broad range of detectors was used in the measurements to record neutron and gamma radiations. Dosimetric and radiometric field measurements of the neutrons and gamma quanta of the radiation scattered in the air were performed at distances of 50 to 1000 m from the reactor during different weather conditions. The neutron spectra in the energy range of 1 eV to 10 MeV and the gamma quanta spectra in the range of 0.1-10 MeV were measured. (author)

  2. Methodology for setting the reference levels in the measurements of the dose rate absorbed in air due to the environmental gamma radiation

    International Nuclear Information System (INIS)

    Dominguez Ley, Orlando; Capote Ferrera, Eduardo; Caveda Ramos, Celia; Alonso Abad, Dolores

    2008-01-01

    Full text: The methodology for setting the reference levels of the measurements of the gamma dose rate absorbed in the air is described. The registration level was obtained using statistical methods. To set the alarm levels, it was necessary to begin with certain affectation level, which activates the investigation operation mode when being reached. It is was necessary to transform this affectation level into values of the indicators selected to set the appearance of an alarm in the network, allowing its direct comparison and at the same time a bigger operability of this one. The affectation level was assumed as an effective dose of 1 mSv/y, which is the international dose limit for public. The conversion factor obtained in a practical way as a consequence of the Chernobyl accident was assumed, converting the value of annual effective dose into values of effective dose rate in air. These factors are the most important in our work, since the main task of the National Network of Environmental Radiological Surveillance of the Republic of Cuba is detecting accidents with a situations regional affectation, and this accident is precisely an example of pollution at this scale. The alarm level setting was based on the results obtained in the first year of the Chernobyl accident. For this purpose, some transformations were achieved. In the final results, a correction factor was introduced depending on the year season the measurement was made. It was taken into account the influence of different meteorological events on the measurement of this indicator. (author)

  3. Prevention of gamma radiation induced anaemia in mice by diltiazem

    International Nuclear Information System (INIS)

    Nunia, V.; Goyal, P.K.

    2004-01-01

    Intraperitoneal administration of diltiazem (DTZ), half an hour prior to whole body gamma irradiation (2.5, 5.0, and 7.5 Gy), showed the protection of animals from radiation-induced anaemia. Radiation exposure significantly (p<0.001) reduced the number of pro- and normoblasts in bone marrow and red blood cell (RBC) counts, hemoglobin (Hb), hematocrit (Hct), and erythropoietin (EPO) level in blood, but increased myeloid/erythroid ratio. At all the radiation doses, the maximum decrease in these values was noted on the 3rd day, followed by a gradual recovery from the 7th day, but it was not recorded as normal even until the end of experimentation. In animals pretreated with DTZ, these values were measured higher at all the time periods in comparison to corresponding control, and these were almost normal at the last autopsy interval only at 2.5 Gy radiation dose. DTZ maintained the higher EPO level in blood, which acted on bone marrow and spleen colony forming unit for erythroblast (CFU-E), and stimulated such cells to produce RBCs. These results confirm that DTZ has the potency to alter anaemic condition favorably through the protection of bone marrow stem cells, and subsequently it maintains the higher number of pro-and normoblasts in bone marrow, RBC counts, Hb, Hct percentage, and EPO level in blood and the lower myeloid/erythroid ratio in bone marrow. (author)

  4. Observations of Galactic gamma-radiation with the SMM spectrometer

    Science.gov (United States)

    Share, G. H.; Kinzer, R. L.; Messina, D. C.; Purcell, W. R.; Chupp, E. L.

    1986-01-01

    Preliminary results from the SMM gamma-ray spectrometer are reported which indicate the detection of a constant source of 0.511-MeV annihilation radiation from the Galaxy. Year-to-year variability appears to be less than 30 percent. The radiation probably comes from a diffuse source and is not associated with the reported compact object at the Galactic center.

  5. Preservation of yams by gamma radiation | Bansa | Journal of the ...

    African Journals Online (AJOL)

    Loss of yam in storage due to sprouting is very high. There is the need to investigate the possibility of inhibiting the sprouting of local varieties of yams using gamma radiation. The effect of radiation on the storage yams and the functionality of the irradiated yams in the Ghanaian food system was studied. Yams were ...

  6. Inhaled /sup 147/Pm and/or total-body gamma radiation: Early mortality and morbidity in rats

    Energy Technology Data Exchange (ETDEWEB)

    Filipy, R.E.; Lauhala, K.E.; McGee, D.R.; Cannon, W.C.; Buschbom, R.L.; Decker, J.R.; Kuffel, E.G.; Park, J.F.; Ragan, H.A.; Yaniv, S.S.; Scott, B.R.

    1989-05-01

    Rats were given doses of /sup 60/Co gamma radiation and/or lung burdens of /sup 147/Pm (in fused aluminosilicate particles) within lethal ranges in an experiment to determine and compare morbidity and mortality responses for the radiation insults within 1 year after exposure. Radiation-induced morbidity was assessed by measuring changes in body weights, hematologic parameters, and pulmonary-function parameters. Acute mortality and morbidity from inhaled promethium were caused primarily by radiation pneumonitis and pulmonary fibrosis that occurred more than 53 days after exposure. Acute mortality and morbidity from total-body gamma irradiation occurred within 30 days of exposure and resulted from the bone-marrow radiation syndrome. Gamma radiation caused transient morbidity, reflected by immediately depressed blood cell levels and by reduced body weight gain in animals that survived the acute gamma radiation syndrome. Inhaled promethium caused a loss of body weight and diminished pulmonary function, but its only effect on blood cell levels was lymphocytopenia. Combined gamma irradiation and promethium lung burdens were synergistic, in that animals receiving both radiation insults had higher morbidity and mortality rates than would be predicted based on the effect of either kind of radiation alone. Promethium lung burdens enhanced the effect of gamma radiation in rats within the first 30 days of exposure, and gamma radiation enhanced the later effect of promethium lung burdens. 70 refs., 68 figs., 21 tabs.

  7. Bioburden assessment and gamma radiation inactivation patterns in parchment documents

    International Nuclear Information System (INIS)

    Nunes, Inês; Mesquita, Nuno; Cabo Verde, Sandra; Carolino, Maria Manuela; Portugal, António; Botelho, Maria Luísa

    2013-01-01

    Parchment documents are part of our cultural heritage and, as historical artifacts that they are, should be preserved. The aim of this study was to validate an appropriate methodology to characterize the bioburden of parchment documents, and to assess the growth and gamma radiation inactivation patterns of the microbiota present in that material. Another goal was to estimate the minimum gamma radiation dose (D min ) to be applied for the decontamination of parchment as an alternative treatment to the current toxic chemical and non-chemical decontamination methods. Two bioburden assessment methodologies were evaluated: the Swab Method (SM) and the Destructive Method (DM). The recovery efficiency of each method was estimated by artificial contamination, using a Cladosporium cladosporioides spore suspension. The parchment samples' microbiota was typified using morphological methods and the fungal isolates were identified by ITS-DNA sequencing. The inactivation pattern was assessed using the DM after exposure to different gamma radiation doses, and using C. cladosporioides as reference. Based on the applied methodology, parchment samples presented bioburden values lower than 5×10 3 CFU/cm 2 for total microbiota, and lower than 10 CFU/cm 2 for fungal propagules. The results suggest no evident inactivation trend for the natural parchment microbiota, especially regarding the fungal community. A minimum gamma radiation dose (D min ) of 5 kGy is proposed for the decontamination treatment of parchment. Determining the minimal decontamination dose in parchment is essential for a correct application of gamma radiation as an alternative decontamination treatment for this type of documents avoiding the toxicity and the degradation promoted by the traditional chemical and non-chemical treatments. - Highlights: • Characterization of the microbial population of parchment documents. • Study the inactivation pattern of parchment microbiota by gamma radiation. • Assessment of

  8. Radiation dose measurements

    International Nuclear Information System (INIS)

    1960-01-01

    About 200 scientists from 28 countries and 5 international organizations met at a symposium on radiation dosimetry held by the International Atomic Energy Agency in June 1960. The aim of the symposium was not so much the description of a large number of measuring instruments as a discussion of the methods used, with special emphasis on those problems which had become important in the context of recent developments, such as the measurement of mixed or very large doses

  9. Gamma ray densitometry techniques for measuring of volume fractions

    Energy Technology Data Exchange (ETDEWEB)

    Affonso, Renato Raoni Werneck; Silva, Ademir Xavier da; Salgado, Cesar Marques, E-mail: raoniwa@yahoo.com.br, E-mail: ademir@nuclear.ufrj.br, E-mail: otero@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    Knowledge of the volume fraction in a multiphase flow is of key importance in predicting the performance of many systems and processes. It is therefore an important parameter to characterize such flows. In the context of nuclear techniques, the gamma ray densitometry is promising and this is due to its non-invasive characteristics and very reliable results. It is used in several applications for multiphase flows (water-oil-air), which are employed tools such as: computational fluid dynamics, artificial neural networks and statistical methods of radiation transport, such as the Monte Carlo method. Based on the gamma radiation techniques for measurements of volume fractions, the aim of this paper is to present several techniques developed for this purpose. (author)

  10. Gamma ray densitometry techniques for measuring of volume fractions

    International Nuclear Information System (INIS)

    Affonso, Renato Raoni Werneck; Silva, Ademir Xavier da; Salgado, Cesar Marques

    2015-01-01

    Knowledge of the volume fraction in a multiphase flow is of key importance in predicting the performance of many systems and processes. It is therefore an important parameter to characterize such flows. In the context of nuclear techniques, the gamma ray densitometry is promising and this is due to its non-invasive characteristics and very reliable results. It is used in several applications for multiphase flows (water-oil-air), which are employed tools such as: computational fluid dynamics, artificial neural networks and statistical methods of radiation transport, such as the Monte Carlo method. Based on the gamma radiation techniques for measurements of volume fractions, the aim of this paper is to present several techniques developed for this purpose. (author)

  11. Continuous monitoring system for environmental {gamma} radiation near nuclear facility

    Energy Technology Data Exchange (ETDEWEB)

    Hua, Jin; Qingyu, Yue; Wenhai, Wang [Academia Sinica, Beijing, BJ (China). Inst. of Atomic Energy

    1996-06-01

    The continuous monitoring system which is used for the environmental routine and accident emergency {gamma} radiation monitoring near nuclear facility is described. The continuous monitoring system consists of a high pressurized ionization chamber, integrated weak current amplifier, V/F converter and intelligent data recorder. The data gained by recorder can be transmitted to a PC through a standard RS-232-C interface for the data handling and graph plotting. This continuous monitoring system has the functions of alarm over threshold and recorded output signal of detector and temperature. The measuring range is from 10 nGy{center_dot}h{sup -1} to 10 mGy{center_dot}h{sup -1} because a high insulation switch atomically changed measuring ranges is used. The monitoring system has been operating continuously for a long time with high stability and reliability. (5 figs., 2 tabs.).

  12. Investigation of the effect of gamma radiation on lincomycin

    International Nuclear Information System (INIS)

    Al-Zier, A; Al- Kassiri, H.; Al Aji, Z.

    2001-01-01

    Sterilization of materials used in medical applications is necessary. Since the use of ethylene oxide will be forbidden in the next future and other sterilization methods as wet, and dry hot sterilization are not suitable for sterilization of drugs, further methods are needed which do not cause a significant decrease in the physical and chemical drug properties. Radiation sterilization can help in many cases. So Gamma or electron radiations were used for sterilization of antibiotics in the solid state as mentioned in the literature. Some antibiotics are already exposed to gamma or electron beam irradiation, and showed significant radiation resistance for low doses, but even small amounts of degradation products are not desirable

  13. Combined effect of gamma radiation and stress cracking in polystyrene

    International Nuclear Information System (INIS)

    Amorim, Fernando A.; Rabello, Marcelo S.; Silva, Leonardo G.A.

    2011-01-01

    This study aimed to evaluate the combined effect of gamma radiation and stress cracking in polystyrene. Three different grades of polystyrene were analysed. The material was submitted to tensile tests and relaxation, analysis of molecular weight and determination of crosslinking. The results showed an increase in tensile strength in the specimens that had been exposed to radiation. The higher the molecular weight polystyrene showed better mechanical properties and after suffering the effects of gamma radiation there was an increase of 5.67% in the resistance to stress cracking effects. (author)

  14. Radiation ray measuring device

    International Nuclear Information System (INIS)

    Maekawa, Tatsuyuki; Ida, Masaki.

    1997-01-01

    The present invention provides a chained-radiation ray monitoring system which can be applied to an actual monitoring system of a nuclear power plant or the like. Namely, this device comprises a plurality of scintillation detectors. Each of the detectors has two light take-out ports for emitting light corresponding to radiation rays irradiated from the object of the measurement to optical fibers. In addition, incident light from the optical fiber by way of one of the light take-out optical ports is transmitted to the other of the ports and sent from the other optical port to the fibers. Plurality sets of measuring systems are provided in which each of the detectors are disposed corresponding to a plurality of objects to be measured. A signal processing device is (1) connected with optical fibers of plurality sets of measuring systems in conjunction, (2) detects the optical pulses inputted from the optical fibers to identify the detector from which the optical pulses are sent and (3) measures the amount of radiation rays detected by the identified detector. As a result, the device of the present invention can form a measuring system with redundancy. (I.S.)

  15. LHCb: Measurement of $A_{\\Gamma}$

    CERN Multimedia

    Smith, M

    2013-01-01

    The measurement of the time dependent CP violating observable $A_{\\Gamma}$ is presented. The result using $1fb^{-1}$ of data from pp collisions at $\\sqrt{s}=7$TeV collected in 2011 is the most accurate to date. No CP violation is observed.

  16. Composite materials. From gammas to weight measurement

    International Nuclear Information System (INIS)

    Anon.

    1998-01-01

    A gamma photons backscattering gauge called 'Filbor 2' has been designed by the CEA/DAMRI (Saclay, France) and allows to measure the resin content of fiber wicks (boron, carbon, kevlar, glass..) devoted to the manufacturing of elements made of composite materials. (J.S.)

  17. Gamma radiation effects on polycarbonate-Durolon

    International Nuclear Information System (INIS)

    Miranda, Adelina.

    1996-01-01

    In this work, the commercial polycarbonate-Durolon, was characterized through measurements of its mechanical, optical viscosimetric and thermal properties, after being irradiated with a 60 Co gamma-source at IPEN-CNEN/SP. These irradiations were carried out different doses and dose rates in air and in vacuum. From the results obtained it was shown that irradiation causes degradation in PC mainly by chain scission, leading to the formation of phenoxy and phenyl radicals which are associated with the yellowness of the material. Both, the concentration of radicals and yellowness of PC increase with the irradiation doses and dose rates. The irradiated PC-Durolon shown a good mechanical stability up to the doses analyzed, but on the other hand, its optical properties do not have the same performance. The viscosity and glass transition temperature of the Durolon decreases with the increase of dose and dose rates. This behavior indicates that main chain scission is the predominant process during irradiation. Furthermore in PC this degradation is higher when the material is irradiated in air, which shows that oxygen also plays an important role in this degradation process. (author). 37 refs., 30 figs., 4 tabs

  18. Control of radioactive wastes and coupling of neutron/gamma measurements: use of radiative capture for the correction of matrix effects that penalize the fissile mass measurement by active neutron interrogation; Controle des dechets radioactifs et couplage de mesures neutron/gamma: exploitation de la capture radiative pour corriger les effets de matrice penalisant la mesure de la masse fissile par interrogation neutronique active

    Energy Technology Data Exchange (ETDEWEB)

    Loche, F

    2006-10-15

    In the framework of radioactive waste drums control, difficulties arise in the nondestructive measurement of fissile mass ({sup 235}U, {sup 239}Pu..) by Active Neutron Interrogation (ANI), when dealing with matrices containing materials (Cl, H...) influencing the neutron flux. The idea is to use the neutron capture reaction (n,{gamma}) to determine the matrix composition to adjust the ANI calibration coefficient value. This study, dealing with 118 litres, homogeneous drums of density less than 0,4 and composed of chlorinated and/or hydrogenated materials, leads to build abacus linking the {gamma} ray peak areas to the ANI calibration coefficient. Validation assays of these abacus show a very good agreement between the corrected and true fissile masses for hydrogenated matrices (max. relative standard deviation: 23 %) and quite good for chlorinated and hydrogenated matrices (58 %). The developed correction method improves the measured values. It may be extended to 0,45 density, heterogeneous drums. (author)

  19. Effect of gamma radiation on ''in vitro''' efficiency of fungicides

    International Nuclear Information System (INIS)

    Menten, J.O.M.; Oliveira, G.C.X.

    1984-01-01

    The activity of 60 Co gamma radiation on eight fungicides used in post-harvesting treatment of agricultural products, was studied. Rhizoctonia solani was used in biological test as indicator-fungus. The fungicides were submitted to gamma radiation doses of O (control), 1, 10, 100, 1000 and 10.000 kR, samples of the fungicides were added to the PSA culture media to obtain 0, 1, 10 and 100 ppm concentrations of the active component of each product and of each radiation dose. The ED 50 (concentration of fungicide necessary to cause 50% radial reduction of the fungic mycelium) of each fungicide in the different gamma radiation doses was determined. (M.A.C.) [pt

  20. Design, construction and calibration of a polarimeter for gamma radiation

    International Nuclear Information System (INIS)

    Macchiavelli, A.O.; Marti, G.V.; Gimenez, C.R.; Laffranchi, J.A.; Behar, M.

    1980-01-01

    Information on different nuclear states can be obtained from the analysis of the angular distribution of the emitted gamma radiation. When the information is not sufficient to determine certain relevant parameters, or is ambiguous, a measurement of the linear polarization of radiation together with the angular distribution allows, in many cases, to resolve this ambiguity. This in turn, necessitates of a detector radiation: this is a Ge(Li) planar detector with a width d of the compensated zone smaller than the length L (L/d greater than 1), built from a germanium block with a square section of 33 mm side, compensated with lithium up to 3 mm depth, by means of usual techniques. The detector characteristics, measured by conventional electronics, were: system's total resolution (Full Width at Half Maximum) 2.4 keV; pico-Compton relation of 6/1 and relative efficiency of 0. for γ rays of 1.33 MeV from 60 Co. Using γ-γ fast-slow coincidence techniques (Ge(Li)-INa system), the curve of polarization efficiency in the 0.1.5 MeV energy range was determined and a polarization efficiency of approximately 17% was obtained for said energy range. This value is comparable to the results obtained in previous works for polarimeters of similar dimensions and can be used to determine multipolarity of nuclear states. (M.E.L.) [es

  1. Designing equipment for use in gamma radiation environments

    International Nuclear Information System (INIS)

    Vandergriff, K.U.

    1990-05-01

    High levels of gamma radiation are known to cause degradation in a variety of materials and components. When designing systems to operate in a high radiation environment, special precautions and procedures should be followed. This report (1) outlines steps that should be followed in designing equipment and (2) explains the general effects of radiation on various engineering materials and components. Much information exists in the literature on radiation effects upon materials. However, very little information is available to give the designer a step-by-step process for designing systems that will be subject to high levels of gamma radiation, such as those found in a nuclear fuel reprocessing facility. In this report, many radiation effect references are relied upon to aid in the design of components and systems. 11 refs., 4 tabs

  2. The central gamma spectrometry laboratory of the GSF Institute of Radiation Protection

    International Nuclear Information System (INIS)

    Ruckerbauer, F.; Dietl, F.; Winkler, R.

    1997-01-01

    Since the middle of 1995 the WG Radioecology is operating the central gamma spectrometry laboratory of the GSF-Institute of Radiation Protection. The main scope of the laboratory is the gamma spectrometric analysis of samples within the research program of the institute and within joint programs with other institutes of the GSF research center. In the present report set-up and technical data of the measuring equipment, the central operating and data evaluation system and measures for quality assurance are described. At that time 18 semiconductor detectors are available for gamma spectrometric sample analysis which is standardized with respect to operation, evaluation algorithms, nuclide data, data safety and documentation. (orig.) [de

  3. Measurements of time differential perturbated angular gamma-gamma correlations in the /sup 207/Bi decay

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Ashok; Soni, S K; Pancholi, S K; Gupta, S L [Delhi Univ. (India). Dept. of Physics and Astrophysics

    1976-10-01

    The results are presented of measuring the differential perturbed angular ..gamma gamma..-correlations for the ..gamma.. 1063.62 - ..gamma.. 569.67 keV cascade in /sup 207/Bi. The results obtained are analyzed and compared with data of other authors.

  4. Spectrometric gamma radiation of shale cores applied to sweet spot discrimination in Eastern Pomerania, Poland

    Science.gov (United States)

    Skupio, Rafal; de Alemar Barberes, Gabriel

    2017-12-01

    This paper describes the application and calculation of hydrocarbon anomalies in two different boreholes located in Eastern Pomerania (northern Poland). Spectrometric data from borehole geophysical probe (borehole 1) and portable gamma logger (borehole 2) were used to analyze shale formations. The results from borehole 1 presented a statistically significant, moderate correlation between calculated hydrocarbon anomalies and hydrocarbon saturation data obtained from well log interpretation. Borehole 2 has been analyzed focusing on the gamma radiation of the core samples, and the positive results of borehole 1. Hydrocarbon anomalies calculated from spectral gamma radiation are reliable indicators of sweet spots, based solely on a cursory evaluation of core measurements. These preliminary information acquired from gamma-ray measurements could help increase sampling precision of further geochemical analysis.

  5. Recent Re-Measurement of Neutron and Gamma-Ray Spectra 1080 Meters from the APRD (Army Pulse Radiation Division) Critical Facility,

    Science.gov (United States)

    1984-01-01

    TISSUE-EQUIVALENT ION CHAMBER GM - GEIGER-MUELLER COUNTER TE-GM - DIFFERENCE BETWEEN TE AND GM DATA MICRODOSE - MICRODOSIMETRY USING 0.5" ROSSI COUNTER...KERMA 4.26+8 1979 APRO NE-213+PR NEUTRON KERMA 4.26+8 1979 WWD NE-213 NEUTRON KERMA 3.10+8 > 550 KEV 1980 DREO MICRODOSE NEUTRON KERMA 4.32+8 1979...APRD GM GAMMA KERMA 3.86+7 1979 WWD NE-213 GAMMA KERMA 4.34+7 > 450 KEV 1980 DREO MICRODOSE GAMMA KERMA 3.90+7 76 1979 APRD TE TOTAL KERMA 4.50+8 50 c.c

  6. Investigation of epigenetic gene regulation in Arabidopsis modulated by gamma radiation

    International Nuclear Information System (INIS)

    Woo, Hye Ryun; Kim, Jae Sung; Lee, Myung Jin; Lee, Dong Joon; Kim, Young Min; Jung, Joon Yong; Han, Wan Keun; Kang, Soo Jin

    2011-12-01

    To investigate epigenetic gene regulation in Arabidopsis modulated by gamma radiation, we examined the changes in DNA methylation and histone modification after gamma radiation and investigated the effects of gamma radiation on epigenetic information and gene expression. We have selected 14 genes with changes in DNA methylation by gamma radiation, analyzed the changes of histone modification in the selected genes to reveal the relationship between DNA methylation and histone modification by gamma radiation. We have also analyzed the effects of gamma radiation on gene expression to investigate the relationship between epigenetic information and gene expression by gamma radiation. The results will be useful to reveal the effects of gamma radiation on DNA methylation, histone modification and gene expression. We anticipate that the information generated in this proposal will help to find out the mechanism underlying the changes in epigenetic information by gamma radiation

  7. Ex-situ and in-situ observations of the effects of gamma radiation on lithium ion battery performance

    Science.gov (United States)

    Tan, Chuting; Bashian, Nicholas H.; Hemmelgarn, Chase W.; Thio, Wesley J.; Lyons, Daniel J.; Zheng, Yuan F.; Cao, Lei R.; Co, Anne C.

    2017-07-01

    Radiation effects induced by gamma rays on battery performance were investigated by measuring the capacity and resistance of a series of battery coin cells in-situ directly under gamma radiation and ex-situ. An experimental setup was developed to charge and discharge batteries directly under gamma radiation, equipped with precise temperature control, at The Ohio State University Nuclear Reactor Lab. Latent effects induced by gamma radiation on battery components directly influence their performance. Charge and discharge capacity and overall resistance throughout a time span of several weeks post irradiation were monitored and compared to control groups. It was found that exposure to gamma radiation does not significantly alter the available capacity and the overall cell resistance immediately, however, battery performance significantly decreases with time post irradiation. Also, batteries exposed to a higher cumulative dose showed close-to-zero capacity at two-week post irradiation.

  8. Laboratory for Calibration of Gamma Radiation Measurement Instruments (LabCal) of Institute of Chemical, Biological, Radiological and Nuclear Defense (IDQBRN) from Brazilian Army Technology Center (CTEx); Laboratorio de Calibracao de Instrumentode Medicao de Radiacao Gama (LabCal) do IDQBRN do CTEx

    Energy Technology Data Exchange (ETDEWEB)

    Amorim, Aneuri de; Balthar, Mario Cesar V.; Santos, Avelino; Vilela, Paulo Ricardo T. de; Oliveira, Luciano Santa Rita; Penha, Paulo Eduardo C. de Oliveira; Gonzaga, Roberto Neves; Andrade, Edson Ramos de; Oliveira, Celio Jorge Vasques de; Fagundes, Luiz Cesar S., E-mail: aneurideamorim@gmail.com [Centro Tecnologico do Exercito (DQBRN/CTEx), Rio de Janeiro, RJ (Brazil). Instituto de Defesa Quimica, Biologica, Radiologica e Nuclear

    2016-07-01

    This paper describes the calibration laboratory deployment steps (LABCAL) gamma ionizing radiation measuring instruments in the Army Technology Center, CTEx. Initially the calibration of radiation monitors will be held in the dosimetric quantity air kerma and operational quantity ambient dose equivalent H*(d). The LABCAL / CTEx has not yet authorized by CASEC / CNEN. This laboratory aims to calibrate the ionizing radiation instruments used by the Brazilian Army. (author)

  9. Study of radiation detectors response in standard X, gamma and beta radiation standard beams

    International Nuclear Information System (INIS)

    Nonato, Fernanda Beatrice Conceicao

    2010-01-01

    The response of 76 Geiger-Mueller detectors, 4 semiconductor detectors and 34 ionization chambers were studied. Many of them were calibrated with gamma radiation beams ( 37 Cs and 60 Co), and some of them were tested in beta radiation ( 90 Sr+ 9' 0Y e 204 Tl) and X radiation (N-60, N-80, N-100, N-150) beams. For all three types of radiation, the calibration factors of the instruments were obtained, and the energy and angular dependences were studied. For beta and gamma radiation, the angular dependence was studied for incident radiation angles of 0 deg and +- 45 deg. The curves of the response of the instruments were obtained over an angle interval of 0 deg to +- 90 deg, for gamma, beta and X radiations. The calibration factors obtained for beta radiation were compared to those obtained for gamma radiation. For gamma radiation, 24 of the 66 tested Geiger-Mueller detectors presented results for the energy dependence according to international recommendation of ISO 4037-2 and 56 were in accordance with the Brazilian ABNT 10011 recommendation. The ionization chambers and semiconductors were in accordance to national and international recommendations. All instruments showed angular dependence less than 40%. For beta radiation, the instruments showed unsatisfactory results for the energy dependence and angular dependence. For X radiation, the ionization chambers presented results for energy dependence according to the national recommendation, and the angular dependence was less than 40%. (author)

  10. Radiation measuring instrument

    International Nuclear Information System (INIS)

    Genrich, V.

    1985-01-01

    A highly sensitive and compactly structured radiation measuring instrument for detecting ionizing radiation, in particular for measuring dose rates and contamination. The laminar structure of the associated counter tube, using only a few, simple plastic parts and a highly elastic counter wire, makes it possible to use the simplest manufacturing techniques. The service life of the counter tube construction, which is completely and permanently sealed and filled with gas, is expected to be more than 12 years. The described counter tube can be adapted in optimal fashion to the available space in a pocket instrument if it is used in combination with a specialized high-voltage generator which is low in interference voltage and with a pulse evaluation circuit having a means of compensating for interference voltage

  11. Gamma radiation effects on polydimethylsiloxane rubber foams under different radiation conditions

    Science.gov (United States)

    Sui, H. L.; Liu, X. Y.; Zhong, F. C.; Li, X. Y.; Wang, L.; Ju, X.

    2013-07-01

    Polydimethylsiloxane rubber foams were irradiated by gamma ray under different radiation conditions designed by orthogonal design method. Compression set measurement, infrared attenuated total reflectance spectroscopy (ATR) and X-ray induced photoelectron spectroscopy (XPS) were used. Three aging factors' influence effects on the mechanical property and chemical structure were studied. It was found that among the three factors and the chosen levels, both properties were affected most by radiation dose, while radiation dose rate had no obvious influence on both properties. The stiffening of the rubber foams was caused by cross-linking reactions in the Si-CH3. At the same radiation dose, the rigidity of the foams irradiated in air was lower than that in nitrogen. When polydimethylsiloxane was irradiated at a high dose in sealed nitrogen atmosphere, carbon element distribution would be changed. Hydrocarbons produced by gamma ray in the sealed tube would make the carbon content in the skin-deep higher than that in the middle, which indicated that polydimethylsiloxane rubber foams storing in a sealed atmosphere filled with enough hydrocarbons should be helpful to extend the service life.

  12. Gamma radiation effects on polydimethylsiloxane rubber foams under different radiation conditions

    Energy Technology Data Exchange (ETDEWEB)

    Sui, H.L. [Department of Physics, University of Science and Technology Beijing, Beijing 100083 (China); Institute of Chemical Materials, CAEP, Mianyang 621900 (China); Liu, X.Y.; Zhong, F.C. [Institute of Chemical Materials, CAEP, Mianyang 621900 (China); Li, X.Y. [Institute of Nuclear Physics and Chemistry, CAEP, Mianyang 621900 (China); Wang, L. [Institute of Chemical Materials, CAEP, Mianyang 621900 (China); Ju, X., E-mail: jux@ustb.edu.cn [Department of Physics, University of Science and Technology Beijing, Beijing 100083 (China)

    2013-07-15

    Polydimethylsiloxane rubber foams were irradiated by gamma ray under different radiation conditions designed by orthogonal design method. Compression set measurement, infrared attenuated total reflectance spectroscopy (ATR) and X-ray induced photoelectron spectroscopy (XPS) were used. Three aging factors’ influence effects on the mechanical property and chemical structure were studied. It was found that among the three factors and the chosen levels, both properties were affected most by radiation dose, while radiation dose rate had no obvious influence on both properties. The stiffening of the rubber foams was caused by cross-linking reactions in the Si–CH{sub 3}. At the same radiation dose, the rigidity of the foams irradiated in air was lower than that in nitrogen. When polydimethylsiloxane was irradiated at a high dose in sealed nitrogen atmosphere, carbon element distribution would be changed. Hydrocarbons produced by gamma ray in the sealed tube would make the carbon content in the skin-deep higher than that in the middle, which indicated that polydimethylsiloxane rubber foams storing in a sealed atmosphere filled with enough hydrocarbons should be helpful to extend the service life.

  13. Development of criticality accident detector measuring neutrons and gamma-rays

    International Nuclear Information System (INIS)

    Tsujimura, Norio; Yoshida, Tadayoshi; Ishii, Masato

    2005-01-01

    The authors developed a new criticality accident detector measuring neutrons and gamma-rays. The detector is a cylindrical plastic scintillator coupled to a current-mode operated photomultiplier, and is covered by an inner cadmium shell, acting as a neutron to gamma-ray converter, and a 5cm thick outer polyethylene moderator in order to respond to the same threshold triggering dose regardless of whether it was exposed to neutrons, gamma-rays or a mixture of the two radiations. (author)

  14. Effects of chemical sensitizers on gamma radiation processing of ...

    African Journals Online (AJOL)

    The potential of gamma radiation processing in cross-linking natural rubber latex (NRL) for production of dipped goods has been studied. NRL produced in Ghana was irradiated to 10, 20, 30, 40 and 50 kGy, respectively, in a Gamma Chamber of dose rate 0.65 kGy/h. Irradiation of the NRL was also carried out in the ...

  15. Gamma radiation effects in vertically aligned carbon nanotubes

    OpenAIRE

    Lubkowski, Grzegorz; Kuhnhenn, Jochen; Suhrke, Michael; Weinand, Udo; Endler, Ingolf; Meißner, Frank; Richter, Sylvia

    2011-01-01

    This paper describes an experimental study of gamma radiation effects in low-density arrays of vertically aligned carbon nanotubes. These arrays are characterized by excellent anti-reflective and absorbing properties for wavelengths from UV to IR, which makes them an interesting option for stray light control in optical space applications. Gamma irradiation equivalent to an estimated surface lifetime exposition in geostationary orbit does not affect the reflectivity of the structures. First h...

  16. Uranium measurement by airborne gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Grasty, R.L.

    1975-01-01

    In the airborne measurement of uranium, window type gamma-ray spectrometers are used and it is necessary to correct for scattered high energy radiation from thallium 208 in the thorium decay series. This radiation can be scattered in the crystal, in the ground, and in the air. A theory, analogous to the theory of radioactive decay, is developed; it can adequately explain the spectrum buildup in the uranium window for a point source of thorium oxide immersed to different depths in water and for a detector above the water. The theory is extended to predict the buildup as a function of altitude for detectors of different sizes and shows that errors in the airborne measurement of uranium can be significant if no allowance is made for radiation scattered in the ground and in the air

  17. Production of radioisotopic gamma radiation sources in JAERI

    International Nuclear Information System (INIS)

    Katoh, Hisashi; Kogure, Hiroto; Suzuki, Kyohei

    1980-04-01

    The present state of production of gamma radiation sources in Japan Atomic Energy Research Institute (JAERI) is described. Sources of 192 Ir, 60 Co and 170 Tm for industrial and 198 Au and 192 Ir for medical applications are produced and delivered routinely by JAERI. Prefabricated assembly targets are irradiated in JRR-2, JRR-3, JRR-4 or JMTR. The irradiated targets are disassembled in a heavy density concrete cave or a lead-shielded cell, depending on the level of radioactivity. The yield of radioactivity in each target is measured with the aid of an ionization chamber. Where necessary, irradiated targets are encapsulated hermetically in capsules of aluminium, stainless steel or other material. The yield of radioactivity is estimated in relation with the burn-up of target nuclide and product nuclide. (author)

  18. Geological influence on terrestrial gamma radiation dose rate in the Malaysian State of Johore

    International Nuclear Information System (INIS)

    Ramli, A.T.; Hussein, A.W.M.A.; Lee, M.H.

    2001-01-01

    Measurements of environmental terrestrial gamma radiation dose-rate (TGRD) have been made in Johore, Malaysia. The focus is on determining a relationship between geological type and TGRD levels. Data were compared using the one way analysis of variance (ANOVA), in some instances revealing significant differences between TGRD measurements and the underlying geological structure

  19. Modification of low density polyethylene, isostatic polypropylene and their blends by gamma radiation

    International Nuclear Information System (INIS)

    Santos Rosa, D. dos

    1991-01-01

    The effects of the gamma radiation (of a 60 Co source), over low density polyethylene, isostatic polypropylene and their blends of low density polyethylene / polypropylene were studied. The structures modifications were attended by infrared spectrometry (IV), differential scanning calorimeter (DSC), strain-strain measurement, density measurement and scanning electron microscope (SEM). (author)

  20. In vitro cell culture lethal dose submitted to gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Moreno, Carolina S.; Rogero, Sizue O.; Rogero, Jose Roberto [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)], e-mail: carolina_sm@hotmail.com; Ikeda, Tamiko I.; Cruz, Aurea S. [Instituto Adolfo Lutz, Sao Paulo, SP (Brazil)

    2009-07-01

    The present study was designed to evaluate the in vitro effect of gamma radiation in cell culture of mouse connective tissue exposed to different doses of gamma radiation and under several conditions. The cell viability was analyzed by neutral red uptake methodology. This assay was developed for establish a methodology to be used in the future in the study of resveratrol radioprotection. Resveratrol (3,4',5- trihydroxystilbene), a phenolic phytoalexin that occurs naturally in some spermatophytes, such as grapevines, in response to injury as fungal infections and exposure to ultraviolet light. In the wines this compound is found at high levels and is considered one of the highest antioxidant constituents. The intense antioxidant potential of resveratrol provides many pharmacological activities including cardioprotection, chemoprevention and anti-tumor effects. Our results demonstrated that {sup 60}Co gamma radiation lethal dose (LD50) on NCTC clone 929 cells was about 340Gy. (author)

  1. In vitro cell culture lethal dose submitted to gamma radiation

    International Nuclear Information System (INIS)

    Moreno, Carolina S.; Rogero, Sizue O.; Rogero, Jose Roberto; Ikeda, Tamiko I.; Cruz, Aurea S.

    2009-01-01

    The present study was designed to evaluate the in vitro effect of gamma radiation in cell culture of mouse connective tissue exposed to different doses of gamma radiation and under several conditions. The cell viability was analyzed by neutral red uptake methodology. This assay was developed for establish a methodology to be used in the future in the study of resveratrol radioprotection. Resveratrol (3,4',5- trihydroxystilbene), a phenolic phytoalexin that occurs naturally in some spermatophytes, such as grapevines, in response to injury as fungal infections and exposure to ultraviolet light. In the wines this compound is found at high levels and is considered one of the highest antioxidant constituents. The intense antioxidant potential of resveratrol provides many pharmacological activities including cardioprotection, chemoprevention and anti-tumor effects. Our results demonstrated that 60 Co gamma radiation lethal dose (LD50) on NCTC clone 929 cells was about 340Gy. (author)

  2. Effect of gamma radiation on honey quality control

    International Nuclear Information System (INIS)

    Bera, A.; Almeida-Muradian, L.B.; Sabato, S.F.

    2009-01-01

    Honey is one of the most complex substances produced by bees, mainly from the nectar of flowers. Gamma radiation is a technique that can be used to decrease the number of microbiological problems associated with food and increase the shelf life of certain products. The objective of this study was to verify the effect of gamma radiation with source of cobalto-60 (10 kGy) on some parameters used in honey quality control. Seven samples of pure honey were obtained from local markets in Sao Paulo, Brazil, in 2007. The methods used are in accordance with Brazilian Regulations. The physicochemical parameters analyzed were: moisture, HMF, free acidity, pH, sugars and ash. The results showed that gamma radiation, in the dose mentioned above, did not cause significant physicochemical alterations.

  3. Effect of gamma radiation on honey quality control

    Energy Technology Data Exchange (ETDEWEB)

    Bera, A. [Radiation Technology Center, IPEN-CNEN/SP, A. Lineu Prestes, 2242, 05508-000 Sao Paulo (Brazil)], E-mail: berale@usp.br; Almeida-Muradian, L.B. [Av. Prof. Lineu Prestes, 580-Cidade Universitaria, Sao Paulo (Brazil); Sabato, S.F. [Radiation Technology Center, IPEN-CNEN/SP, A. Lineu Prestes, 2242, 05508-000 Sao Paulo (Brazil)], E-mail: sfsabato@ipen.br

    2009-07-15

    Honey is one of the most complex substances produced by bees, mainly from the nectar of flowers. Gamma radiation is a technique that can be used to decrease the number of microbiological problems associated with food and increase the shelf life of certain products. The objective of this study was to verify the effect of gamma radiation with source of cobalto-60 (10 kGy) on some parameters used in honey quality control. Seven samples of pure honey were obtained from local markets in Sao Paulo, Brazil, in 2007. The methods used are in accordance with Brazilian Regulations. The physicochemical parameters analyzed were: moisture, HMF, free acidity, pH, sugars and ash. The results showed that gamma radiation, in the dose mentioned above, did not cause significant physicochemical alterations.

  4. Effects of gamma radiation in cauliflower (Brassica spp) minimally processed

    International Nuclear Information System (INIS)

    Nunes, Thaise C.F.; Rogovschi, Vladimir D.; Thomaz, Fernanda S.; Trindade, Reginaldo A.; Villavicencio, Anna L.C.H.; Alencar, Severino M.

    2007-01-01

    Consumers demand for health interests and the latest diet trends. The consumption of vegetables worldwide has increased every year over the past decade, consequently, less extreme treatments or additives are being required. Minimally processed foods have fresh-like characteristics and satisfy the new consumer demand. Food irradiation is an exposure process of the product to controlled sources of gamma radiation with the intention to destroy pathogens and to extend the shelf life. Minimally processed cauliflower (Brassica oleraceae) exposed to low dose of gamma radiation does not show any change in sensory attributes. The aim of this study was to analyze the effects of the low doses of gamma radiation on sensorial aspects like appearance, texture and flavor of minimally processed cauliflower. (author)

  5. A new extremity dosemeter for beta and gamma radiation

    International Nuclear Information System (INIS)

    Heinzelmann, M.; Pagenkamper, M.

    1988-01-01

    An extremity dosemeter developed at the Juelich Nuclear Research Centre is very well suited for the precise and energy-independent measurement of the skin dose generated by beta or gamma radiation. This is also confirmed by the results of this intercomparison programme. The dosemeter contains three TLDs of LiF in Teflon mounted behind a window of 0.9 mg/cm 2 . The great advantage of this dosemeter is three TLD's enabling statements about the radiation quality. However, the dosemeter has two disadvantages The dosemeter is complicated to manufacture. A very thin plastic foil of 0.9 mg/cm 2 must be attached to a support. This work is difficult and time-consuming and cannot be automated. The window in front of the TLD is not sturdy enough and is occasionally destroyed when the dosemeter is being worn. These two disadvantages prevent this extremity dosemeter from being used more frequently. For this reason, work was begun on developing a new extremity dosemeter without these two disadvantages. The great advantage of the previous dosemeter of obtaining statements about the type of radiation with the aid of readings from three TLD's was to be retained. The improved extremity dosemeter has a more sturdy and thicker window with a similar response as the previous dosemeter with a thinner window

  6. A national-wide survey of radon and gamma radiation levels in Australian homes

    International Nuclear Information System (INIS)

    Langaroo, M.K.; Wise, K.N.; Duggleby, J.K.; Kotler, L.H.

    1990-04-01

    A nation-wide survey of Australian homes has been conducted to determine the average annual doses to the Australian population from exposure to radon and gamma radiation. The exposure to radon was measured using solid state track detectors (SSTD) whilst the gamma radiation dose was concurrently determined using thermoluminescent dosimetry. Dosemeters were placed in approximately 3400 randomly distributed homes (representing about 1 in 1400 occupied dwellings) for twelve months. The measured annual average radon concentration in Australian homes is 12 Bq m -3 . Using appropriate conversion factors, the annual average effective dose equivalents to the Australian population were determined to be 0.6 mSv and 0.9 mSv for radon and gamma radiation respectively. 20 refs., 3 tabs., 7 figs

  7. Isodose mapping of terrestrial gamma radiation dose rate of Selangor state, Kuala Lumpur and Putrajaya, Malaysia

    International Nuclear Information System (INIS)

    Sanusi, M.S.M.; Ramli, A.T.; Gabdo, H.T.; Garba, N.N.; Heryanshah, A.; Wagiran, H.; Said, M.N.

    2014-01-01

    A terrestrial gamma radiation survey for the state of Selangor, Kuala Lumpur and Putrajaya was conducted to obtain baseline data for environmental radiological health practices. Based on soil type, geological background and information from airborne survey maps, 95 survey points statistically representing the study area were determined. The measured doses varied according to geological background and soil types. They ranged from 17 nGy h −1 to 500 nGy h −1 . The mean terrestrial gamma dose rate in air above the ground was 182 ± 81 nGy h −1 . This is two times higher than the average dose rate of terrestrial gamma radiation in Malaysia which is 92 nGy h −1 (UNSCEAR 2000). An isodose map was produced to represent exposure rate from natural sources of terrestrial gamma radiation. - Highlights: • A methodology is presented to reduce terrestrial gamma dose rate field survey. • Geological background of acid intrusive of granitic type has the highest dose rates. • The mean dose rate is 2 times higher than the world average. • Isodose map of terrestrial gamma radiation for Selangor, Kuala Lumpur and Putrajaya was produced

  8. Synthesis of graphene using gamma radiations

    Indian Academy of Sciences (India)

    graphene oxide (GO) by the gamma irradiation technique using a relatively low dose rate of 0.24 kGy h−1 has been ... photo-catalysis, electrochemical sensors and biosensors.5–10 ... Methanol, ethanol, isopropanol and tert-butanol were.

  9. Synthesis of graphene using gamma radiations

    Indian Academy of Sciences (India)

    Considering the advantages of radiolytic synthesis such as the absence of toxic chemical as a reducing agent, uniform distribution of reducing agent and high purity of product, the synthesis of graphene (rGO) from graphene oxide (GO) by the gamma irradiation technique using a relatively low dose rate of 0.24 kGy h−1 has ...

  10. Study of the contribution of the radon in the measurement with an automatic gamma probe

    International Nuclear Information System (INIS)

    Caveda Ramos, C.A.; Dominguez Levy, O.; Alonso Abad, D.; Montalvan Estrada, A.; Fabelo Bonet, O.

    2008-01-01

    In this work, study about the influence of the radon in the daily measurements of the dose rate absorbed in air due to the environmental gamma radiation is achieved. This magnitude is measured each ten minutes for the Gamma Tracer probe, which is located in the western station of the National Network of Environmental Radiological Surveillance of the Republic of Cuba, this station belongs to the Center of Protection and Hygiene of the Radiations (CPHR). For achieving such study approximately 157 680 measurements of the gamma dose rate corresponding the period 2004-2006 were analyzed. The gamma probe used has two independent counter channels which are both complemented with a Geiger-Muller detector; also it can only detect gamma radiation and perform measurements of the gamma dose rate between 8.7 n Gy/h and 8.7 mGy/h. This probe is located at the height of 3.5 m and is exposed to the sun rays directly. For improving the interpretation of the data, the average of all the values of gamma dose rate was calculated, for each hour of the 365 days of the year. The values were also monthly averaged out. The data were processed by employing the software Gamma Red which was improved by adding some options. A comparison between the results obtained and the annual radon variation internationally published was made. With the present study, it was proved that the main contribution to the daily measurements of the dose rate absorbed in the air due to environmental gamma radiation, on stable weather conditions, is associated with the radon daughters which emit gamma radiation. (author)

  11. Void Measurement by the ({gamma}, n) Reaction

    Energy Technology Data Exchange (ETDEWEB)

    Rouhani, S Zia

    1962-09-15

    It is proposed to use the ({gamma}, n) reaction for the measurement of the integrated void volume fraction in two phase flow of D{sub 2}O inside a duct. This method is applicable to different channel geometries, and it is shown to be insensitive to the pattern of void distribution over the cross-sectional area of the channels The method has been tested on mock-ups of voids in a round duct of 6 mm inside diameter. About 40 m.c. {sup 24}Na was used as a source of gamma-rays. The test results show that the maximum measured error in this arrangement is less than 2.5 % (net void) for a range of 2.7 % to 44.44 % actual void volume fractions.

  12. Precision measurements of the CKM angle gamma

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    The level of CP-violation permitted within the Standard Model cannot account for the matter dominated universe in which we live. Within the Standard Model the CKM matrix, which describes the quark couplings, is expected to be unitary. By making precise measurements of the CKM matrix parameters new physics models can be constrained, or with sufficient precision the effects of physics beyond the standard model might become apparent. The CKM angle gamma is the least well known angle of the unitarity triangle. It is the only angle easily accessible at tree-level, and furthermore has almost no theoretical uncertainties. Therefore it provides an invaluable Standard Model benchmark against which other new physics sensitive tests of the CP-violation can be made. I will discuss recent measurements of gamma using the the Run 1 LHCb dataset, which improve our knowledge of this key parameter.

  13. Gamma radiation effects on vitamin C standard solutions

    International Nuclear Information System (INIS)

    Amaro, Jose Daniel V.; Mansur Netto, Elias

    1995-01-01

    This word shows the physical - chemical effects of gamma radiation on standard solutions of vitamin C. Samples with concentration of 50 mg/ml were exposed to different doses of gamma radiations: 1,0 2,5 and 5,0 kGy, using a cobalt-60 source, with storing periods of 0,15 and 30 days. The results showed a vitamin C concentration loss, with a minimum of 17% for the dose of 1,0 kGy immediately after irradiation and a maximum of 81% for the dose of 5 kGy and 30 days after irradiation. (author). 3 refs., 2 tabs

  14. Research of pulse gamma ray radiation effect on microcontroller system

    International Nuclear Information System (INIS)

    Yang Shanchao; Ma Qiang; Jin Xiaoming; Li Ruibin; Lin Dongsheng; Chen Wei; Liu Yan

    2012-01-01

    An experimental result of power chip LM7805 and microcontroller EE80C196KC20 based on the EE80C196KC20 testing system was presented. The pulse gamma ray radiation effect was investigated using 'Qiangguang-Ⅰ' accelerator. Latchup threshold of the microcontroller was obtained, and the relationship of supply current and I/O output with the transient dose rate was observed. The result shows that the restrainability of power chip on pulse gamma ray radiation induces microcontroller latchup effect. (authors)

  15. Detection and measurement of ionizing radiation by the Radioactive Waste Management Centre

    International Nuclear Information System (INIS)

    Mudra, Josef

    2013-01-01

    The following topics are dealt with: Basic properties of radionuclides and selection of suitable detectors; radiation characteristics of sealed sources (radiation detection, dose rate measurement, surface contamination measurement, gamma spectroscopy); non-destructive analysis (segment gamma scanner, digital radiography); destructive analysis; radiation monitoring of humans and workplaces; and dosimetric monitoring of workplace surroundings and discharges. (orig.)

  16. The Study of Radiation of Gamma-Ray Background at Sedimentology Laboratorium, P3TIR, BATAN, Using Gamma Spectrometry

    International Nuclear Information System (INIS)

    Lubis, Ali Arman; Aliyanta, Barokah; Darman

    2002-01-01

    The measurement of background radiation of gamma-ray has been done at Sedimentology Laboratory, SDAL building, P3TIR, BATAN using gamma spectrometer. The measurement was done without shielding with the range of energy between 50 keV and 1500 keV. The identified radiations are coming from environmental radionuclide and man-made radionuclide as well with 32 energy peaks. The environmental radionuclides are from Uranium series, Thorium series, and 4 0 K having dose rate of 12.510 ± O.980, 36.408 ± 3.243, 9.455 ±O.016 n Sv/day, respectively, whilst man-made radionuclide is 6 O C o having dose rate of O.136 ±O.078 n Sv/day

  17. Gamma radiation at coal mines and sections

    International Nuclear Information System (INIS)

    Pavlov, I.V.; Kuznetsov, A.T.

    1991-01-01

    The problem of radiation background in coal miner and open pits conditioned by γ-radiation of coals and enclousing rocks containing natural radioactive isotopes ( 40 K, 226 Ra, 232 Th) is analyzed. The data are presented on average content of the above isotopes in coals, hard rocks and earth crest; γ-dose rate in mines and open pits as well as on possible limits and average values of external γ-radiation in mines. It is shown that external γ-radiation is an insignificant factor of radiation hazard in mines and open pits. Systematic monitoring of and accounting for external radiation dose of the personnel are required only in mines where average concentration of 226 Ra exceeds 200 Bqxkg -1 , and that of 232 Th - 150 Bqxkg -1

  18. Research building gamma Compton scattering measurement system and related exercises for training nuclear human resources

    International Nuclear Information System (INIS)

    Mai Xuan Phong; Nguyen Van Hung; Pham Xuan Hai; Le Van Ngoc; Nguyen Xuan Hai; Dang Lanh; Tran Quoc Duong

    2013-01-01

    In this subject we have designed and manufactured Compton scattering gamma measurement system based on the calculated optimal configuration as well as the conditions of protect radiation by using Monte-Carlo simulation program and fabrication with the optimal conditions were selected. Monte-Carlo simulation calculation of Compton scattering gamma follow different angles on copper, surveying gamma radiation attenuation characteristics of materials: lead, iron, aluminum, and compared with the experimental results performed on the same measurement system has been built and given for evaluation, comments. (author)

  19. Direct Effects Of Chronic Gamma Radiation On Musa Acuminata Var. Berangan, A Local Malaysia Banana Cultivar

    International Nuclear Information System (INIS)

    Maimum Tahir; Azhar Mohamad; Rozeita Laboh; Umikalsum Mohd Bahari

    2014-01-01

    Musa acuminata var. Berangan, is a popular variety of our local banana known as Pisang Berangan. The variety is a triploid banana, use mainly for dessert and has a great value for commodity fruit crops. However, production of PisangBerangan has been threatened by diseases such as Fusarium wilt, black sigatoka, Fusarium wilt, burrowing nematodes and viral diseases like Banana streak virus, Banana bunch top virus and Banana bract mosaic virus. The scenario becoming worst as Musa has a narrow genetic background for breeding and/or selection program. The banana breeding program of edible bananas is hampered by high sterility, and very limited amounts of seeds. Mutation induction via chronic gamma radiation is an alternative ways in creating more variants for selections towards a better quality and disease tolerance. A total number of 75 samples at nursery stage (1 month) were exposed to chronic gamma radiation in Gamma Greenhouse at Malaysian Nuclear Agency for 28 weeks. The samples were accordingly arranged with distance ranging from 1 m to 15 m from gamma source (Cesium-137). Plant height and new buds were used as measurement parameters in evaluating the direct effects of the chronic gamma radiation. Results showed effective dose of chronic gamma radiation in Pisang Berangan was 20 Gy. Number of new emerging sucker was ranging from 1-3 pieces with the highest at ring-4 and ring-5. Plant height was observed ranging from 22.1 to 110.5 cm. Effects of chronic radiation were observed after 3-4 months in the GGH. The samples revealed as striking leaves, short inter node and new emergence of suckers. The objective of this work is to get a dose response for chronic gamma radiation in Pisang Berangan. As for selection of potential mutant variants, new emerging suckers were tissue cultured in segregating chimeras and to get required numbers of samples for further field evaluation. (author)

  20. Gamma radiation stability studies of mercury fulminate

    International Nuclear Information System (INIS)

    Fondeur, F.F.

    2000-01-01

    Mercury fulminate completely decomposed in a gamma source (0.86 Mrad/h) after a dose of 208 Mrad. This exposure equates to approximately 2.4 years in Tank 15H and 4 years in Tank 12H, one of the vessels of concern. Since the tanks lost the supernatant cover layer more than a decade ago, this study suggests that any mercury fulminate or closely related energetic species decomposed long ago if ever formed

  1. Gamma radiation influences postharvest disease incidence of pineapple fruits

    International Nuclear Information System (INIS)

    Damayanti, M.; Sharma, G.J.; Kundu, S.C.

    1992-01-01

    The application of gamma radiation for improving the storage of pineapple fruits [Ananas comosus (L.) Merr. cv. Queen] has been studied in an attempt to reduce decay caused by fungal pathogens such as Ceratocystis paradoxa (Dade)-Moreau and Penicillium purpurogenum Stoll. Gamma radiation at 50, 75, 100, 150, and 250 Gy improved shelf life. The maximum tolerable dose was approximately 250 Gy. Fruits irradiated with up to 150 Gy and then stored at 25 to 28C maintained their texture better than did the controls. Radiation, particularly at doses 250 Gy, caused browning of the skin and softening of tissues. Browning increased with increasing radiation dose and storage duration. Excessively high doses promoted spoilage. Doses in the range of 50 to 250 Gy, in combination with storage at 11 to 13C, can be used to reduce postharvest losses in pineapple due to fungal diseases and senescence, thereby extending shelf life

  2. Characteristics of liver tissue for attenuate the gamma radiation; Caracteristicas del tejido hepatico para atenuar la radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Arcos P, A.; Rodriguez N, S.; Pinedo S, A.; Amador V, P.; Chacon R, A.; Vega C, H.R. [Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico)

    2005-07-01

    It was determined the lineal attenuation coefficient of hepatic tissue before gamma radiation of a source of {sup 137} Cs. When exposing organic material before X or gamma radiation fields, part of the energy of the photons is absorbed by the material, while another part crosses it without producing any effect. The quantity of energy that is absorbed is a measure of the dose that receives the material. The three main mechanisms by means of which the gamma rays interacting with the matter are: The Photoelectric Effect, the Compton dispersion and the Even production; the sum of these three processes is translated in the attenuation coefficient of the radiation. In this work we have used hepatic tissue of bovine, as substitute of the human hepatic tissue, and we have measured the lineal attenuation coefficient for photons of 0.662 MeV. Through a series of calculations we have determined the lineal attenuation coefficient for photons from 10{sup -3} to 10{sup -5} MeV and the measured coefficient was compared with the one calculated. (Author)

  3. Silicon detectors for x and gamma-ray with high radiation resistance

    International Nuclear Information System (INIS)

    Cimpoca, Valerica; Popescu, Ion V.; Ruscu, Radu

    2001-01-01

    Silicon detectors are widely used in X and gamma-ray spectroscopy for direct detection or coupled with scintillators in high energy nuclear physics (modern collider experiments are representative), medicine and industrial applications. In X and gamma dosimetry, a low detection limit (under 6 KeV) with silicon detectors becomes available. Work at the room temperature is now possible due to the silicon processing evolution, which assures low reverse current and high life time of carriers. For several years, modern semiconductor detectors have been the primary choice for the measurement of nuclear radiation in various scientific fields. Nowadays the recently developed high resolution silicon detectors found their way in medical applications. As a consequence many efforts have been devoted to the development of high sensitivity and radiation hardened X and gamma-ray detectors for the energy range of 5 - 150 keV. The paper presents some results concerning the technology and behaviour of X and Gamma ray silicon detectors used in physics research, industrial and medical radiography. The electrical characteristics of these detectors, their modification after exposure to radiation and the results of spectroscopic X and Gamma-ray measurements are discussed. The results indicated that the proposed detectors enables the development of reliable silicon detectors to be used in controlling the low and high radiation levels encountered in a lot of application

  4. Curcumin Attenuates Gamma Radiation Induced Intestinal Damage in Rats

    International Nuclear Information System (INIS)

    EI-Tahawy, N.A.

    2009-01-01

    Small Intestine exhibits numerous morphological and functional alterations during radiation exposure. Oxidative stress, a factor implicated in the intestinal injury may contribute towards some of these alterations. The present work was designed to evaluate the efficacy of curcumin, a yellow pigment of turmeric on y-radiation-induced oxidative damage in the small intestine by measuring alterations in the level of thiobarbituric acid reactive substances (TSARS), serotonin metabolism, catecholamine levels, and monoamine oxidase (MAO) activity in parallel to changes in the architecture of intestinal tissues. In addition, monoamine level, MAO activity and TSARS level were determined in the serum. Curcumin was supplemented orally via gavages, to rats at a dose of (45 mg/ Kg body wt/ day) for 2 weeks pre-irradiation and the last supplementation was 30 min pre exposure to 6.5 Gy gamma radiations (applied as one shot dose). Animals were sacrificed on the 7th day after irradiation. The results demonstrated that, whole body exposure of rats to ionizing radiation has induced oxidative damage in small intestine obvious by significant increases of TSARS content, MAO activity and 5-hydroxy indole acetic acid (5-HIAA) and by significant decreases of serotonin (5-HT), dopamine (DA), norepinephrine (NE) and epinephrine (EPI) levels. In parallel histopathological studies of the small intestine of irradiated rats through light microscopic showed significant decrease in the number of villi, villus height, mixed sub mucosa layer with more fibres and fibroblasts. Intestinal damage was in parallel to significant alterations of serum MAO activity, TBARS, 5-HT, DA, NE and EPI levels. Administration of curcumin before irradiation has significantly improved the levels of monoamines in small intestine and serum of irradiated rats, which was associated with significant amelioration in MAO activity and TBARS contents

  5. Use of gamma radiation for preparation of nutrient culture media

    Energy Technology Data Exchange (ETDEWEB)

    Speranskaya, I.D.; Tumanyan, M.A.; Mironova, L.L.

    1977-01-01

    A technique was developed for sterilization of nutrient culture media using ..gamma..-radiation. For this purpose, dry preparations were exposed to 3 to 6 Mrad radiation, then dissolved in sterile distilled water. The quality of media and solutions thus obtained is as good as that of preparations sterilized by filtration. The advantage of the proposed sterilization method is that liquid media can be rapidly prepared and dry sterile media can be stored at room temperature for long periods of time.

  6. Gamma radiation hazard to miners in bituminous coal mines

    International Nuclear Information System (INIS)

    Skubacz, K.

    1986-01-01

    Radiation hazard to miners working in 16 bituminous coal mines was determined by a thermoluminescence method. While the miners exposure to gamma radiation is higher than that of the general population, the yearly dose was never found to exceed 5 mSv in any investigated person. Factors contributing to the estimate of the exposure hazard and the need for individual dose monitoring in mines are discussed in more detail. 3 refs., 4 figs. (author)

  7. Gamma radiation effects on different sorts of onions

    International Nuclear Information System (INIS)

    Burov, B.A.

    1977-01-01

    Gamma radiation effects on different sorts of onions were studied to improve ways of obtaining agricultural vegetation mutations and to find out the genotype role in induced mutagenesis. It is established that rhizome onion seeds are more radiosensitive than bulbous ones, ephemeroide form seeds are most stable among bulbous plants. Table data on dependence of seed germination and plant survival on radiation dose are presented

  8. Laser flow microphotometry for rapid analysis and sorting of mammalian cells. [X and gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Mullaney, P.F.; Steinkamp, J.A.; Crissman, H.A.; Cram, L.S.; Crowell, J.M.; Salzman, G.C.; Martin, J.C.; Price, B.

    1976-01-01

    Quantitative precision measurements can be made of the optical properties of individual mammalian cells using flow microphotometry. Suspended cells pass through a special flow chamber where they are lined up for exposure to blue light from an argon-ion laser. As each cell crosses the laser beam, it produces one or more optical pulses of a duration equal to cell transit time across the beam. These pulses are detected, amplified, and analyzed using the techniques of gamma ray spectroscopy. Quantitative DNA distributions made it possible to distinguish tumor cells from normal cells as well as to assay for radiation effects on tumor cells subjected to x and gamma radiation. (HLW)

  9. Application of Glycine-TTC dosimeter in gamma radiation processing facility

    International Nuclear Information System (INIS)

    Shinde, S.H.; Mondal, S.; Kulkarni, M.S.

    2018-01-01

    Glycine-TTC dosimeter was found to have a useful dose range of 5 to 30 kGy using spectro-photometric read-out method. Potential use of this dosimeter was demonstrated by measuring dose-rate in gamma chamber GC 900. The aim of the present study was to verify the performance of this dosimeter in actual industrial processing conditions encountered in radiation processing facility such as Gamma Radiation Processing Plant for Spices (GRPPS), BRIT, Vashi. Accordingly, glycine-TTC dosimeters were irradiated along with routine dosimeter viz. ceric-cerous of GRPPS and reference standard dosimeter viz. alanine EPR

  10. Gamma-Ray Dosimetry System Using Radiation-Resistant Optical Fibers and a Luminescent Material

    International Nuclear Information System (INIS)

    Toh, K.; Nakamura, T.; Yamagishi, H.; Sakasai, K.; Soyama, K.; Shikama, T.; Nagata, S.

    2013-06-01

    Gamma-ray dosimetry system using radiation-resistant optical fibers and a luminescent material was developed for use in a damaged Fukushima Dai-ichi nuclear power plant. The system was designed to be compact and unnecessary of an external supply of electricity to a radiation sensor head with a contaminated working environment and restricted through-holes to a measurement point in the damaged reactor. The system can detect a gamma-ray dose rate at a measurement point using a couple of optical fibers and a luminescent material with a coincidence method. This system demonstrated a linear response with respect to the gamma-ray dose rate from 0.5 mGy/h to 0.1 Gy/h and the system had a capability to measure the dose rate of more than 10 2 Gy/h. (authors)

  11. Measurement of gamma radioactivity in steel

    International Nuclear Information System (INIS)

    Wachtendonk, H.J. von; Flock, J.; Grientschnig, D.; Kircher, T.; Kroos, J.; Mertens, S.; Mueller, J.; Puchmayr, J.; Schlothmann, B.J.; Schmitz, H.U.; Troebs, V.; Unger, H.

    1999-01-01

    The steel industry is being confronted increasingly with radioactive scrap from dismantled nuclear facilities. The clearance and release regulations that exist around the world differ very greatly and are difficult to implement. A 'radioactivity measurement' working group has therefore been set up at VDEh to clarify how radioactive measurements can be integrated into the day-to-day production routine. Operating results obtained at Thyssen Krupp Stahl AG with a gamma-ray spectrometer indicate a possibility for the simple detection of radioactive contamination. (orig.) [de

  12. SENSITIVITY OF THE CUMIN SEEDS ASSOCIATED FUNGI TO GAMMA RADIATION

    International Nuclear Information System (INIS)

    BOTROS, H.W.; HELAL, I.M.; EL TOBGY, K.M.K.

    2008-01-01

    The present study was carried out to investigate the sensitivity of fungi associated to cumin seeds for gamma radiation. In this regard, the isolated seed associated fungi from the cumin seeds were fifteen fungal species belonging to five genera. The fungal species concerning, Aspergillus ochraceus, Fusarium oxysporium and Aspergillus flavus were the predominant fungi in percentages of 17.8, 15.83 and 12.78 %, respectively. Aspergillus ochraceus was the most effective prevalent fungi on the seed germination causing highest percentage of seed invasion followed by Fusarium oxysporium and Aspergillus flavus. The amylolytic, proteolytic and lipolytic activity and mycotoxin production of the three predominant fungi were negatively influenced by gamma radiation when exposed to doses of 1.0 , 1.5 , 2.5 , 3.5 , 5.0 and 7.5 kGy a behaviour which was parallel to the inhibition in the amount of growth by gamma irradiation

  13. Radiation detection and measurement

    International Nuclear Information System (INIS)

    Knoll, G.F.

    1979-01-01

    Introductory material covers radiation sources, radiation interactions, general properties of radiation detectors, and counting statistics and error prediction. This is followed by detailed sections on gas-filled detectors, scintillation counters, semiconductor detectors, neutron detectors and spectroscopy, detector electronics and pulse processing, and miscellaneous radiation detectors and applications

  14. LHCb: Measurement of Gamma from $B \\rightarrow DK$ Decays

    CERN Multimedia

    Hussain, N

    2013-01-01

    The angle $\\gamma$ of the CKM Unitarity Triangle is the only one that can be measured directly at tree level. Direct measurements of $\\gamma$ constrain the triangle and any deviations from unity may be an indication of new physics. This poster presents three analyses that look at a variety of $B \\rightarrow DK$ decays, whose information is then combined to perform a $\\gamma$ measurement. The best fit value of $\\gamma$ is ${71.1^{+16.1}_{-15.2}} ^\\circ$.

  15. The secondary biogenic radiation of gamma-irradiated human blood

    International Nuclear Information System (INIS)

    Kuzin, A.M.; Surkenova, G.N.; Budagovskij, A.V.; Gudi, G.A.

    1997-01-01

    The sample of blood freshly taken from healthy men were gamma-irradiated with a dose of 10 Gy. It was shown that after the treatment the blood gained the capacity to emit secondary biogenic radiation. Emission lasted for some hours, passed through quartz-glass curette and was revealed by stimulating influence on biological detector (sprouting seeds)

  16. Study of the effect of the gamma radiation in polycarbonate

    International Nuclear Information System (INIS)

    Khoury, H.J.; Araujo, E.S. de; Silveira, S.V. da

    1990-01-01

    To estimate the radiation effects in the DUROLON polycarbonate, samples were irradiated with 60 Co gamma beam with doses between 0,2KGy and 50KGy. The results obtained shown variations in the yellowed index above 1KGy dose. Their mechanical proprieties are not changed at interval of this doses. (author) [pt

  17. Computed temperature profile in materials exposed to gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Ping, Tso Chin; Choong, Yap Siew; Seon, Chan Kam

    1987-06-01

    Computed temperature profiles are presented for the materials of lead, steel, concrete and water in curved shells, when they are exposed to gamma radiation. The results are based on the usual simplified theory of thermal conduction with an exponential heat source.

  18. Study of local Agregate for Gamma radiation concrete shield

    International Nuclear Information System (INIS)

    Tochrul-Binowo; Endro-Kismolo; Darsono

    1996-01-01

    Investigation on the composition of gamma radiation concrete shield made of local barite, manganese fine and coarse aggregates from Kulon Progo, Yogyakarta has been done. The purpose of the research was to find out the quality of these local material for an aggregate of gamma radiation concrete shield. The research was done where each mineral was used as coarse aggregate and the fine aggregate from Kulon Progo was used as fine basic aggregate. Firstly a normal concrete was made by mixing cement, fine aggregate, coarse aggregate and water at a weight ratio of cement: fine aggregate: coarse: water 1: 2.304: 3.456: 0.58. The gamma radiation absorption capacity of the concrete tested by using Cs-137 as source standard. The same method was done on barite concrete at the weight ratio of cement: fine aggregate: barite aggregate: water 1: 2.303: 3.456: 0.58 and manganese concrete at the weight ratio of cement: fine aggregate: manganese aggregate: and water 1: 1.896: 2.844: 0.58. The result of the study showed that the gamma radiation absorption capacity of barite aggregate was greater than that of normal concrete and manganese concrete. The coefficient linear attenuation (for 6.0 cm thickness) of each concrete were μ barite concrete = 0.23071 cm -1 , μ manganese concrete = 0.08401 cm -1 and μ normal concrete = 0.1669 cm -1

  19. Treatment of tannery effluent by irradiation. [gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Roszak, W; Pekala, W

    1983-01-01

    Different samples of tannins were exposed to gamma radiation at room temperature. Some of them were aerated during irradiation.In irradiated samples the concentration of phenol and organic substances decreased and their biodegradability increased. Aerated samples had a higher decrease of phenol concentration. (E.G.M.).

  20. Sewage sludge pasteurization by gamma radiation: financial viability case studies

    International Nuclear Information System (INIS)

    Swinwood, J.F.; Kotler, J.

    1990-01-01

    This paper examines the financial viability of sewage sludge pasteurization by gamma radiation, by examining the following three North American scenarios: 1. Small volume sewage treatment plant experiencing high sludge disposal costs; 2. Large volume sewage treatment plant experiencing low sludge disposal costs; 3. Large volume sewage treatment plant experiencing high sludge disposal costs. (author)

  1. Sewage sludge pasteurization by gamma radiation: financial viability case studies

    Energy Technology Data Exchange (ETDEWEB)

    Swinwood, J.F.; Kotler, J. (Nordion International Inc., Kanata, Ontario (Canada))

    1990-01-01

    This paper examines the financial viability of sewage sludge pasteurization by gamma radiation, by examining the following three North American scenarios: 1. Small volume sewage treatment plant experiencing high sludge disposal costs; 2. Large volume sewage treatment plant experiencing low sludge disposal costs; 3. Large volume sewage treatment plant experiencing high sludge disposal costs. (author).

  2. Comparative effects of X and gamma radiations on rice plantules

    International Nuclear Information System (INIS)

    Gumberra, R.; Gonzalez, L.M.

    1993-01-01

    Results on effects of 60C o X and gamma ray on rice plantules from irradiated seeds in the dosage interval ranging from zero to 1000Gy in low level sources are shown in this work. A similar effect within the same range of radiations, with some difference in its biological efficiency was observed

  3. Sewage sludge pasteurization by gamma radiation: Financial viability case studies

    Science.gov (United States)

    Swinwood, Jean F.; Kotler, Jiri

    This paper examines the financial viability of sewage sludge pasteurization by gamma radiation, by examining the following three North American scenarios: 1) Small volume sewage treatment plant experiencing high sludge disposal costs. 2) Large volume sewage treatment plant experiencing low sludge disposal costs. 3) Large volume sewage treatment plant experiencing high sludge disposal costs.

  4. Effect of gamma radiation on Campylobacter jejuni

    International Nuclear Information System (INIS)

    Lambert, J.D.; Maxcy, R.B.

    1984-01-01

    Radiation resistance of Campylobacter jejuni in broth, ground beef, and ground turkey meat was determined using dose levels from 0-200 Krad at -30 +/- 10 0 C, at 0-5 0 C, and at 30 +/- 10 0 C. Irradiation at -30 0 C increased radiation resistance of cultures in ground meats; broth cultures were not greatly influenced by temperature. The effect of culture age on radiation resistance was also evaluated using cells in various physiological phases. Age did not have a pronounced effect on radiation resistance. The largest D 10 value for C. jejuni was 32 Krad, which was less than D 10 values commonly reported for salmonellae. 20 references, 4 figures

  5. Astrophysical applications of Delbrück scattering: Dust scattered gamma radiation from gamma ray bursts

    International Nuclear Information System (INIS)

    Kunwar, B.; Bhadra, A.; Gupta, S.K. Sen

    2014-01-01

    A preliminary, and perhaps the first, study of astrophysical applications of Delbrück scattering in a gamma-ray emitting celestial object like a gamma-ray burst (GRB) has been made. At energies≥100 MeV the elastic scattering of gamma-ray photons off the molecular dust surrounding the GRB site is dominated by Delbrück scattering. Expressions for Delbrück-scattered gamma-ray flux as a function of time has been obtained for a few selected energies by assuming a simple model of GRB. These are compared with Compton-scattered flux. At certain situations, interestingly, the former is found to exceed the latter for the first few milliseconds of the burst. The issue of detectability of Delbrück-scattered gamma-ray echo from the cloud of a GRB is discussed. Although it is observed that the detection of such an echo is not within the capability of the presently operating gamma-ray missions such as Fermi LAT, a rough estimate shows that one can be optimistic that future generation gamma-ray telescopes might be able to see such photons' contribution to the total flux. - Highlights: ► Astrophysical application of Delbrück scattering in a GRB has been made. ► Initially, the Delbrück scattering may dominate the scattering of GeV γ-rays. ► The issue of detectability of such radiations is discussed

  6. Effect of neutron and gamma radiations on zeolite and zeotype materials

    International Nuclear Information System (INIS)

    Durrani, S.K.

    1994-01-01

    The influence of gamma and (n, gamma)-radiation on the cation exchange and the structure of zeolite and zeotype materials has been studied. Samples were subjected to different doses of gamma-irradiation varying between 0.5 and 10 MGy and Neutron irradiation flux varied from 1.14 x 10/sup 17/ to 3.88 x /sup 10/sup 17/n cm/sup -2/. Structural effects consequent to gamma irradiation were examined by x-ray diffraction, electron scanning micrographs and FTIR measurements. Neutron and gamma-irradiation and not lead by any appreciable change in the structure, however, the displacement cations to locked-in sites results partial reduced barium and caesium uptake. The decrease of the intensities of the absorption bands of the hydroxy-groups reveals that gamma-irradiation has a strong dehydrating influence. THe effects of gamma-radiation on (UO/sub 2/)/sup 2+/ and Am/sup 3+/ uptake into NH/sub 4/-L and NH/sub 4/-SAPO-34 was also observed. K alpha of the uranyl ions increased with increasing pH up to 6.3. At pH > 3.5, the uranyl ions were precipitated and consequently K alpha values were continued to increased. (author)

  7. Decay Curves and Half-Lives of Gamma-Emitting States from a Study of Prompt Fission Gamma Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Albinsson, H [Chalmers Univ. of Technology, Goeteborg (SE)

    1971-04-15

    Measurements were made on the time distributions of the prompt gamma radiation emitted from fragments in the thermal-neutron induced fission of 235U. The gamma radiation emitted during different time intervals after the fission event was studied with the help of a collimator, the position of which was changed along the path of the fragments. In this way decay curves were obtained from which half-lives could be estimated. Time components with half-lives of 7.5, 18 and 60 ps were found and their relative intensities were calculated. Half-lives and associated intensities are in good agreement with earlier data from uranium and californium fission. Problems involved in this type of study are discussed. The collimator technique has proved to be effective for determination of half lives down to less than 10 ps

  8. Neutron and gamma dose and spectra measurements on the Little Boy replica

    International Nuclear Information System (INIS)

    Hoots, S.; Wadsworth, D.

    1984-01-01

    The radiation-measurement team of the Weapons Engineering Division at Lawrence Livermore National Laboratory (LLNL) measured neutron and gamma dose and spectra on the Little Boy replica at Los Alamos National Laboratory (LANL) in April 1983. This assembly is a replica of the gun-type atomic bomb exploded over Hiroshima in 1945. These measurements support the National Academy of Sciences Program to reassess the radiation doses due to atomic bomb explosions in Japan. Specifically, the following types of information were important: neutron spectra as a function of geometry, gamma to neutron dose ratios out to 1.5 km, and neutron attenuation in the atmosphere. We measured neutron and gamma dose/fission from close-in to a kilometer out, and neutron and gamma spectra at 90 and 30 0 close-in. This paper describes these measurements and the results. 12 references, 13 figures, 5 tables

  9. Continuous weighing of conveyor-transported materials based on gamma radiation conversion to electric current

    International Nuclear Information System (INIS)

    The principle is described of the continuous weighing of conveyer-transported materials applied in the food industry. The weighing technique is based on the measurement of the absorption of gamma radiation emitted by a source located behind the material to be scaled. (Z.M.)

  10. Enhancement of ZnO-rGO nanocomposite thin films by gamma radiation for E. coli sensor

    Energy Technology Data Exchange (ETDEWEB)

    Noor Azmy, Noor Azwen [Department of Electrical, Electronic and System Engineering, Faculty of Engineering and Built Environment, 43650, UKM, Bangi, Selangor (Malaysia); Bakar, Ahmad Ashrif A., E-mail: ashrif@ukm.edu.my [Department of Electrical, Electronic and System Engineering, Faculty of Engineering and Built Environment, 43650, UKM, Bangi, Selangor (Malaysia); Arsad, Norhana [Department of Electrical, Electronic and System Engineering, Faculty of Engineering and Built Environment, 43650, UKM, Bangi, Selangor (Malaysia); Idris, Sarada [Department of Electrical, Electronic and System Engineering, Faculty of Engineering and Built Environment, 43650, UKM, Bangi, Selangor (Malaysia); Radiation Facilities Division, Block 42, Malaysian Nuclear Agency, Bangi, 43000 Kajang, Selangor (Malaysia); Mohmad, Abdul Rahman [MEMS-NEMS and Nanoelectronics, Institute of Microengineering and Nanoelectronics (IMEN), 43650 UKM, Bangi, Selangor (Malaysia); Abdul Hamid, Aidil [School of Biosciences and Biotechnology, Faculty of Science and Technology, 43650 UKM, Bangi, Selangor (Malaysia)

    2017-01-15

    Highlights: • ZnO-rGO nanocomposite thin films by gamma radiation for E. coli sensor were fabricated for the first time. • Exposed to gamma radiation leads to the change the microstructure of the films. • The optical behaviors of thin films were found to be gamma dose dependent. • The sensors had a linear response with GO concentration. • The sensors exhibited enhanced sensitivity at higher gamma radiation. - Abstract: The fabricated E. coli sensor of ZnO-rGO nanocomposite thin films by gamma radiation was investigated. Nanocomposite films were prepared via sol–gel method and were irradiated at 10 kGy at room temperature. The surface characteristic of as-prepared samples have been characterized by x-ray diffraction (XRD), fourier transform infrared spectroscopy (FTIR), atomic force microscopy (AFM) and field emission scanning electron microscopy (FESEM). The proposed structure shows that exposed gamma radiation may change the microstructure of the films occurs as a result of their flexible structure. Uv–vis spectra of nanocomposite were studied to investigate the optical behavior of ZnO-rGO films and the optical energy band gap and Urbach energy were found to be gamma dose dependent. The sensing properties were identified by measuring the changes of conductivity of film using I-V measurement. Upon exposure to E. coli, the radiated ZnO-rGO films (1.00 vol% GO) exhibited higher sensitivity, as much as 4.62 × 10{sup −3}, than un-radiated films, 1.04 × 10{sup −3}. This enhancement of the I-V response was attributed to a positive influence of the gamma radiation in these films. The results prove that our ZnO-rGO nanocomposites thin films by gamma radiation demonstrate a strong performance for the detection of microbiological organisms in water.

  11. Instrumentation measurement and testing complex for detection and identification of radioactive materials using the emitted radiation

    International Nuclear Information System (INIS)

    Samossadny, V.T.; Dmitrenko, V.V.; Kadlin, V.V.; Kolesnikov, S.V.; Ulin, S.E.; Grachev, V.M.; Vlasik, K.F.; Dedenko, G.L.; Novikov, D.V.; Uteshev, Z.M.

    2006-01-01

    Simultaneous measurement of neutron and gamma radiation is a very usefull method for effective nuclear materials identification and control. The gamma-ray-neutron complex described in the paper is based on two multi-layer 3 He neutrons detectors and two High Pressure Xenon gamma-ray spectrometers assembled in one unit. All these detectors were callibrated on neutron and gamma-ray sources. The main characteristics of the instrumentation , its testing results and gamma-ray and neutron radiation parameters, which have been measured are represented in the paper. The gamma-neutron sources and fissile materials reliable detection and identification capability was demonstrated

  12. Radiative decay of the eta-, eta'-mesons in the nonlocal quark model. [eta(eta'). --> gamma gamma. ; eta. -->. pi. /sup +/. pi. /sup -/. gamma. ; eta. -->. pi. /sup 0/2. gamma. ; eta'. -->. rho/sup 0/. gamma. ; eta'. -->. omega gamma. ;. pi. /sup 0/. -->. gamma. e/sup +/e/sup -/; eta(eta'). -->. gamma mu. /sup +/. mu. /sup -/

    Energy Technology Data Exchange (ETDEWEB)

    Efimov, G V; Ivanov, M A; Nogovitsyn, E A [Joint Inst. for Nuclear Research, Dubna (USSR)

    1981-07-01

    P..--> gamma gamma.. (P=..pi../sup 0/, eta, eta'), eta..--> pi../sup +/..pi../sup -/..gamma.., eta..--> pi../sup 0/..gamma gamma.., eta/sup 1/..-->..V..gamma.. (V=rho/sup 0/, ..omega..), p..--> gamma..l/sup +/l/sup -/ (p=..pi../sup 0/, eta, eta') radiation decays are studied for testing the applicability of the non-local quark model for description of the experimental data. The Feynman diagrams of these decays are presented, values of the widths of the Veta..--> gamma gamma.., eta..--> pi../sup +/..pi../sup -/..gamma.., eta..--> pi../sup 0/..gamma gamma.., eta'..--> gamma gamma.., eta'..-->..rho/sup 0/..gamma.., eta'..--> omega gamma.. decays are calculated and given in the form of a table. Calculations are carried out for two values of the eta eta'-crossing angle: THETA=-11 deg and -18 deg. Values of invariant amplitudes of these decays are determined for ..pi../sup 0/..--> gamma..e/sup +/e/sup -/, eta..--> gamma mu../sup +/..mu../sup -/, eta'..--> gamma mu../sup +/..mu../sup -/ decays at THETA=-11 deg and -18 deg. The best agreement with the experimental data is noted to take place at THETA=-11 deg, the determined width of the eta..--> pi../sup 0/..gamma gamma.. decays is underestimated as compared with the experimental one.

  13. Gamma spectrometric methods for measuring plutonium

    International Nuclear Information System (INIS)

    Gunnink, R.

    1978-01-01

    Nondestructive analyses of plutonium can be made by detecting and measuring the gamma rays emitted by a sample. Although qualitative and semiquantitative assays can be performed with relative ease, only recently have methods been developed, using computer analysis techniques, that provide quantitative results. This paper reviews some new techniques developed for measuring plutonium. The features of plutonium gamma-ray spectra are reviewed and some of the computer methods used for spectrum analysis are discussed. The discussion includes a description of a powerful computer method of unfolding complex peak multiplets that uses the standard linear least-squares techniques of data analysis. This computer method is based on the generation of response profiles for the isotopes composing a plutonium sample and requires a description of the peak positions, relative intensities, and line shapes. The principles that plutonium isotopic measurements are based on are also developed, followed by illustrations of the measurement procedures as applied to the quantitative analysis of plutonium liquid and solid samples

  14. Measurements of impurity spectra using UV/visible spectroscopic system in a GAMMA 10 plasma

    International Nuclear Information System (INIS)

    Matama, K.; Yoshikawa, M.; Kobayashi, T.; Kubota, Y.; Cho, T.

    2006-01-01

    Impurity spectra have been measured and identified using a newly designed ultraviolet and visible (UV/visible) spectroscopic system in the tandem mirror GAMMA 10. It is constructed using two spectrometers to obtain an entire wavelength range of UV/visible impurity spectra with a high wavelength resolution in one plasma shot. We successfully obtained the emission intensities of the radiation spectra in detail and information on the time-varying population densities of the impurities. We evaluate radiation loss from the GAMMA 10 plasma in the UV/visible range; further we estimate the electron density and temperature after applying the measured spectral intensity to a collisional-radiative model

  15. Alteration of yeast activity by gamma radiation

    International Nuclear Information System (INIS)

    Chacharkar, M.P.; Tak, B.B.; Bhati, J.

    1996-01-01

    Yeast is an important component in microbe based industrial technologies. Due to the techno-economic reasons, the fermentation technique has acquired renewed interest. The effect of γ-radiation on the fermentation reaction has been investigated. The studies show that exposure of the fermentation mixture to γ-radiation at 5 kGy enhance alcohol production, whereas irradiation at higher doses, viz., 10 kGy and 25 kGy caused a considerable reduction in the alcohol yield. Therefore, low dose irradiation of fermentation mixtures can be applied for increasing the alcohol production by about 25%. (author). 13 refs., 1 fig

  16. Disinfection of sewage water and sludge using gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Musaad, R M.A. [Department of Radiation Chemistry, Atomic Energy Research Coordination Council, Sudan Academy of Sciences, Khartoum (Sudan)

    2008-04-15

    This study has been carried out to assess the efficiency of gamma radiation in disinfecting sewage water and sludge from harmful pathogenic bacteria (e.g. Streptococcus, Salmonella, Shigella, total E-coli and total coliform), parasites (Ascaris ova) as well as its ability to degrade organic matter (BOD). Samples were exposed to gamma-radiation doses ranging from 0.5 to 8 KGy using Co''6{sup 0} cell. Amongst pathogenic bacteria which are subjected to different doses of gamma-radiation Streptococcus faecalis revealed to be the most resistance bacterial indicator since complete elimination of these bacteria could be attained at 3.5 KGy. While total e-coli shown to be the most sensitive with lethal dose at 2 KGy. The radiation doses that required for reducing the bacterial population by 90% (D{sub 10}) and 50% (D {sub 50}) were determined for each species. The D{sub 10} values found ranged from 0.75 KGy for Streptococcus and 2.75 KGy for total count bacteria. On the other hand, D{sub 50} fall within the range of 0.5 KGy for total count bacteria, total coliform and Streptococcus, and 1.0 KGy for total e-coli. With regard to the efficiency of radiation treatment to destroy Ascaris ova viability it was found that no larvae were viable after exposure to 1.0 KGy following incubation of exposed ova for four weeks period.(Author)

  17. Disinfection of sewage water and sludge using gamma radiation

    International Nuclear Information System (INIS)

    Musaad, R.M.A.

    2008-04-01

    This study has been carried out to assess the efficiency of gamma radiation in disinfecting sewage water and sludge from harmful pathogenic bacteria (e.g. Streptococcus, Salmonella, Shigella, total E-coli and total coliform), parasites (Ascaris ova) as well as its ability to degrade organic matter (BOD). Samples were exposed to gamma-radiation doses ranging from 0.5 to 8 KGy using Co''6 0 cell. Amongst pathogenic bacteria which are subjected to different doses of gamma-radiation Streptococcus faecalis revealed to be the most resistance bacterial indicator since complete elimination of these bacteria could be attained at 3.5 KGy. While total e-coli shown to be the most sensitive with lethal dose at 2 KGy. The radiation doses that required for reducing the bacterial population by 90% (D 10 ) and 50% (D 50 ) were determined for each species. The D 10 values found ranged from 0.75 KGy for Streptococcus and 2.75 KGy for total count bacteria. On the other hand, D 50 fall within the range of 0.5 KGy for total count bacteria, total coliform and Streptococcus, and 1.0 KGy for total e-coli. With regard to the efficiency of radiation treatment to destroy Ascaris ova viability it was found that no larvae were viable after exposure to 1.0 KGy following incubation of exposed ova for four weeks period.(Author)

  18. Rheology of Indian Honey: Effect of Temperature and Gamma Radiation

    Directory of Open Access Journals (Sweden)

    Sudhanshu Saxena

    2014-01-01

    Full Text Available Honey brands commonly available in Indian market were characterized for their rheological and thermal properties. Viscosity of all the honey samples belonging to different commercial brands was found to decrease with increase in temperature (5–40°C and their sensitivity towards temperature varied significantly as explained by calculating activation energy based on Arrhenius model and ranged from 54.0 to 89.0 kJ/mol. However, shear rate was not found to alter the viscosity of honey indicating their Newtonian character and the shear stress varied linearly with shear rate for all honey samples. Honey is known to contain pathogenic microbial spores and in our earlier study gamma radiation was found to be effective in achieving microbial decontamination of honey. The effect of gamma radiation (5–15 kGy on rheological properties of honey was assessed, and it was found to remain unchanged upon radiation treatment. The glass transition temperatures (Tg of these honey analyzed by differential scanning calorimetry varied from −44.1 to −54.1°C and remained unchanged upon gamma radiation treatment. The results provide information about some key physical properties of commercial Indian honey. Radiation treatment which is useful for ensuring microbial safety of honey does not alter these properties.

  19. Influence on cell proliferation of background radiation or exposure to very low, chronic gamma radiation

    International Nuclear Information System (INIS)

    Planel, H.; Soleilhavoup, J.P.; Tixador, R.; Richoilley, G.; Conter, A.; Croute, F.; Caratero, C.; Gaubin, Y.

    1987-01-01

    Investigations carried out on the protozoan Paramecium tetraurelia and the cyanobacteria Synechococcus lividus, which were shielded against background radiation or exposed to very low doses of gamma radiation, demonstrated that radiation can stimulate the proliferation of these two single-cell organisms. Radiation hormesis depends on internal factors (age of starting cells) and external factors (lighting conditions). The stimulatory effect occurred only in a limited range of doses and disappeared for dose rates higher than 50 mGy/y

  20. Gamma radiation inside closed volumes with thin irradiating walls

    International Nuclear Information System (INIS)

    Karpov, V.I.

    1978-01-01

    The dose rate of gamma radiation inside a parallelepiped with thin radiating walls was calculated. The calculation was based on determining the dose rate from a rectangular plate and subsequently summing the dose rates from all the parallelepiped walls. The dose rate from the rectangular plate was calculated by reducing it to an equivalent plate of infinite length and certain fixed width. When the radiators had constant surface density, the dose rate in the geometric centre of volumes having the form of a parallelepiped was shown to have the least value in the case when the parallelepiped degenerates to a cube

  1. Characterization of crumb rubber modified by gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Faldini, Sonia B.; Terence, Mauro C.; Miranda, Leila F.; Munhoz, Antonio H.; Domingues, Leandro S.; Coghetto, Gregory, E-mail: sfaldini@yahoo.com.br, E-mail: mauroterence@yahoo.com.br [Universidade Presbiteriana Mackenzie (UPM), Sao Paulo, SP (Brazil). Escola de Engenharia. Engenharia de Materiais

    2013-07-01

    The use of crumb rubber from scrap tires has become a common practice in the construction of roads, leading to improved properties of the asphalt and decreasing the environmental pollution. In this study, crumb rubber was modified by gamma radiation to eventually incorporate it into the asphalt and verify potential improvements of their properties. The crumb rubber modified by gamma radiation in the dose 500 kGy and 1000kGy was characterized by thermal analysis, infrared spectroscopy and scanning electron microscopy. The dose of radiation used has no effect on degradation temperatures. It is observed that the IV spectra of untreated rubbers and rubbers irradiated have substantially the same profile. The results indicate that despite small morphological changes in the irradiated rubber, they do not influence its degradation temperature and composition. (author)

  2. Characterization of crumb rubber modified by gamma radiation

    International Nuclear Information System (INIS)

    Faldini, Sonia B.; Terence, Mauro C.; Miranda, Leila F.; Munhoz, Antonio H.; Domingues, Leandro S.; Coghetto, Gregory

    2013-01-01

    The use of crumb rubber from scrap tires has become a common practice in the construction of roads, leading to improved properties of the asphalt and decreasing the environmental pollution. In this study, crumb rubber was modified by gamma radiation to eventually incorporate it into the asphalt and verify potential improvements of their properties. The crumb rubber modified by gamma radiation in the dose 500 kGy and 1000kGy was characterized by thermal analysis, infrared spectroscopy and scanning electron microscopy. The dose of radiation used has no effect on degradation temperatures. It is observed that the IV spectra of untreated rubbers and rubbers irradiated have substantially the same profile. The results indicate that despite small morphological changes in the irradiated rubber, they do not influence its degradation temperature and composition. (author)

  3. Effect of glucocorticoids and gamma radiation on epidermal Langerhans cells

    International Nuclear Information System (INIS)

    Belsito, D.V.; Baer, R.L.; Thorbecke, G.J.; Gigli, I.

    1984-01-01

    The effect of 750 rads of gamma radiation on the rate of return of epidermal Langerhans cells (LC) following suppressive doses of topical glucorticoids was studied in guinea pigs. Gamma radiation alone had no effect on the LC as assessed by staining for cell membrane ATPase activity and Ia antigen. It did, however, delay the expected return of Ia but not ATPase surface markers on the LC after perturbation with glucocorticoids. The delayed return of surface Ia antigen is possibly related to a radiation-induced defect in the production of a required lymphokine and/or in intracellular Ia transport. Although our data do not rule out a cytolytic effect of steroids on the LC, they do strongly suggest that, at least in part, glucocorticoids act on the LC by altering cell surface characteristics

  4. Polycarbonate Durolon degradation submitted to gamma radiation

    International Nuclear Information System (INIS)

    Miranda, A.; Sciani, V.

    1993-01-01

    The Polycarbonate (PC) Durolon, produced by Policarbonatos do Brasil S.A. with molecular weight 27,000 g/mol was irradiated with 60-Co gamma ray source at IPEN-CNEN/SP with doses range between 0.2 to 1,000 kGy in air at 25 C. The results showed that up to 20 kGy no changes in mechanical properties were observed. Above this value, a drop of the elongation to break was observed, reaching 50% drop of its value by 500 kGy. On the other hand, optical tests showed that about 5 kGy some transmittance variations occurred, reaching 3% of its value for a dose of 300 kGy. (author)

  5. Yield of Prompt Gamma Radiation in Slow-Neutron Induced Fission of 235U as a Function of the Total Fragment Kinetic Energy

    Energy Technology Data Exchange (ETDEWEB)

    Albinsson, H [Chalmers Univ. of Technology, Goeteborg (SE)

    1971-07-01

    Fission gamma radiation yields as functions of the total fragment kinetic energy were obtained for 235U thermal-neutron induced fission. The fragments were detected with silicon surface-barrier detectors and the gamma radiation with a Nal(Tl) scintillator. In some of the measurements mass selection was used so that the gamma radiation could also be measured as a function of fragment mass. Time discrimination between the fission gammas and the prompt neutrons released in the fission process was employed to reduce the background. The gamma radiation emitted during different time intervals after the fission event was studied with the help of a collimator, the position of which was changed along the path of the fission fragments. Fission-neutron and gamma-ray data of previous experiments were used for comparisons of the yields, and estimates were made of the variation of the prompt gamma-ray energy with the total fragment kinetic energy

  6. Degradation study of Durolon polycarbonate submitted to gamma radiation

    International Nuclear Information System (INIS)

    Miranda, A.; Sciani, V.

    1992-01-01

    The effect of gamma radiation from a cobalt 60 source in the 27000 Durolon polycarbonate irradiated with doses between 0,2 and 1000 kGy at 25 0 C was analyzed. For this reason the samples was submitted to the mechanical assay of tension, deformation and hardness and optical assay of transmittance. The obtained results show a good mechanical stability of the polycarbonate, when it was submitted to gamma irradiation in doses up to 20 kGy. (C.G.C.). 05 refs., 04 figs

  7. Sterilization of spices and vegetable seasoning by gamma radiation

    International Nuclear Information System (INIS)

    Lescano, G.; Narvaiz, P.; Kairiyama, E.

    1991-01-01

    Ginger, turmeric, Cayenne pepper, onion and garlic powders were gamma irradiated with doses of 10 and 30 kGy, and stored at room temperature for six months. Microbiological, chemical and sensory analyses were performed. Samples were sterilized with 30 kGy. The pH values of water extracts of these condiments appear practically unchanged by the applied gamma radiation doses. Spectrophotometric analysis of methyl alcohol extracted of the pigments showed no irradiation effect in turmeric and ginger. Seasoning capacity (odour, flavour and pungency) were not altered by 30 kGy irradiation. (author) 24 refs.; 2 figs.; 4 tabs

  8. Sterilization of sera and vaccines by cobalt gamma radiation

    International Nuclear Information System (INIS)

    Guidolin, R.; Morais, J.F.; Higashi, H.G.; Correa, A.; Cicarelli, R.M.B.; Previde, E.

    1988-01-01

    Diphtheria, tetanus, anti-snake venom sera and Diphtheria-Pertussis-Tetanus vaccine were submitted to different intensities of gamma radiation, in order to: verify the resistance of their specific activities to the action of gamma rays; evaluate the possibility of using this type of energy to sterilize some heterogeneous hyper immune sera and vaccines commonly utilized in Public Health. The results, according to the range employed, show the possibility of sterilizing the products tested, without any alteration to specific biological and chemical properties. (author)

  9. Cosmic gamma radiation of ultra high energy of primordial origin

    International Nuclear Information System (INIS)

    Aquino Filho, F.G. de.

    1984-01-01

    The quantum mechanical effects near a collapsing black hole as shown by Stephen W.Hawking in 1974 to produce streaming particles through tunneling effect was explored in the context of cosmic gamma ray production. In this thesis, we show the possible production of gamma rays of high energies (ν approx 10 41 Hz) in the initial stages of the formation of the Universe by the explosion of primordial mini black holes. These mini black hole explosions happening at 10 -43 s to 10 -37 s after the start perhaps may account for the existing universal cosmic background radiation of 2.7 0 K. (Author) [pt

  10. Radiation safety for operators of gamma irradiation plants

    International Nuclear Information System (INIS)

    1989-01-01

    These notes have been prepared by the UK Panel for Gamma and Electron Irradiation with advice from the HSE (Technology Division and Factory and Agricultural Inspectorate) to assist operators of Gamma irradiation plants to comply with the requirements of the Ionising Radiations Regulations (IRR 1985), and other relevant regulations (see below). The process is currently used for the sterilisation of medical devices and in the treatment of plastics materials etc. The Government has proposed that the process should also be permitted for the treatment of foodstuffs, and these notes will also be relevant to any irradiation plants which may be used in the UK for this purpose. (author)

  11. Measurement and detection of radiation

    CERN Document Server

    Tsoulfanidis, Nicholas

    2015-01-01

    This fourth edition reflects recent major developments that have occurred in radiation detector materials, systems, and applications. It continues to provide the most practical and up-to-date introduction to radiation detector technology, proper measurement techniques, and analysis of results for engineers and scientists using radiation sources. New chapters emphasize the expanded use of radiation detection systems in nuclear non-proliferation, homeland security, and nuclear medicine. The book also discusses the correct ways to perform measurements following current health physics procedures.

  12. Dosimetry techniques of thermal neutrons and {gamma} radiation in reactor cores; Techniques de dosimetrie des neutrons thermiques et du rayonnement {gamma} dans les piles

    Energy Technology Data Exchange (ETDEWEB)

    Sutton, J; Draganic, I; Hering, H [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1955-07-01

    Chemical studies under radiation done in the reactor cores require to be followed by dosimetry. When the irradiations are done in the reflector, one can limit to the measure of the {gamma} and the neutron radiation. For the dosimetry of the {gamma} radiation, a dosimeter of ferrous sulfate is convenient until doses of about 10{sup 6} rep. The use of aired oxalic acid solutions permits to reach 10{sup 7} rep. The dosimetry of thermal neutrons has been made with solutions of cobalt sulphate or paper filter impregnated with this salt. The total chemical effect of the {gamma} and of the slow neutrons radiation is obtained with solutions of ferrous sulfate added with lithium sulphate. (M.B.) [French] Les etudes de chimie sous radiation faites dans les piles exigent d'etre suivies par dosimetrie. Lorsque les irradiations sont effectues dans le reflecteur, on peut se limiter a doser le rayonnement {gamma} et les neutrons. Pour la dosimetrie du rayonnement {gamma}, un dosimetre a sulfate ferreux convient jusqu'a des doses d'environ 10{sup 6} rep. L'emploi de solutions aerees d'acide oxalique permet d'atteindre 10{sup 7} rep. La dosimetrie des neutrons thermiques a ete faite avec des solutions de sulfate de cotalt ou du papier filtre impregne de ce sel. L'effet chimique total du rayonnement {gamma} et des neutrons lents est obtenu avec des solutions de sulfate ferreux additionne de sulfate de lithium. (M.B.)

  13. Field Deployable Gamma Radiation Detectors for DHS Use

    Energy Technology Data Exchange (ETDEWEB)

    Sanjoy Mukhopadhyay

    2007-08-01

    Recently, the Department of Homeland Security (DHS) has integrated all nuclear detection research, development, testing, evaluation, acquisition, and operational support into a single office: the Domestic Nuclear Detection Office (DNDO). The DNDO has specific requirements set for all commercial off-the-shelf and government off-the-shelf radiation detection equipment and data acquisition systems. This article would investigate several recent developments in field deployable gamma radiation detectors that are attempting to meet the DNDO specifications. Commercially available, transportable, handheld radio isotope identification devices (RIID) are inadequate for DHS requirements in terms of sensitivity, resolution, response time, and reach-back capability. The leading commercial vendor manufacturing handheld gamma spectrometer in the United States is Thermo Electron Corporation. Thermo Electron's identiFINDER{trademark}, which primarily uses sodium iodide crystals (3.18 x 2.54cm cylinders) as gamma detectors, has a Full-Width-at-Half-Maximum energy resolution of 7 percent at 662 keV. Thermo Electron has just recently come up with a reach-back capability patented as RadReachBack{trademark} that enables emergency personnel to obtain real-time technical analysis of radiation samples they find in the field. The current project has the goal to build a prototype handheld gamma spectrometer, equipped with a digital camera and an embedded cell phone to be used as an RIID with higher sensitivity, better resolution, and faster response time (able to detect the presence of gamma-emitting radio isotopes within 5 seconds of approach), which will make it useful as a field deployable tool. The handheld equipment continuously monitors the ambient gamma radiation, and, if it comes across any radiation anomalies with higher than normal gamma gross counts, it sets an alarm condition. When a substantial alarm level is reached, the system automatically triggers the saving of relevant

  14. Field Deployable Gamma Radiation Detectors for DHS Use

    International Nuclear Information System (INIS)

    Sanjoy Mukhopadhyay

    2007-01-01

    Recently, the Department of Homeland Security (DHS) has integrated all nuclear detection research, development, testing, evaluation, acquisition, and operational support into a single office: the Domestic Nuclear Detection Office (DNDO). The DNDO has specific requirements set for all commercial off-the-shelf and government off-the-shelf radiation detection equipment and data acquisition systems. This article would investigate several recent developments in field deployable gamma radiation detectors that are attempting to meet the DNDO specifications. Commercially available, transportable, handheld radio isotope identification devices (RIID) are inadequate for DHS requirements in terms of sensitivity, resolution, response time, and reach-back capability. The leading commercial vendor manufacturing handheld gamma spectrometer in the United States is Thermo Electron Corporation. Thermo Electron's identiFINDER(trademark), which primarily uses sodium iodide crystals (3.18 x 2.54cm cylinders) as gamma detectors, has a Full-Width-at-Half-Maximum energy resolution of 7 percent at 662 keV. Thermo Electron has just recently come up with a reach-back capability patented as RadReachBack(trademark) that enables emergency personnel to obtain real-time technical analysis of radiation samples they find in the field. The current project has the goal to build a prototype handheld gamma spectrometer, equipped with a digital camera and an embedded cell phone to be used as an RIID with higher sensitivity, better resolution, and faster response time (able to detect the presence of gamma-emitting radio isotopes within 5 seconds of approach), which will make it useful as a field deployable tool. The handheld equipment continuously monitors the ambient gamma radiation, and, if it comes across any radiation anomalies with higher than normal gamma gross counts, it sets an alarm condition. When a substantial alarm level is reached, the system automatically triggers the saving of relevant

  15. Measurement of neutron and gamma-ray production double differential cross section at KEK

    International Nuclear Information System (INIS)

    Ishibashi, Kenji

    1995-01-01

    High energy nuclear radiations were measured for 0.8-3.0 GeV proton induced reactions at KEK. The measurement was carried out to overcome the problems arising from the use of secondary beam line of a quite low incident beam intensity. Digital pulse shape discrimination method was applicable to separation between high energy neutrons and gamma-rays. By the use of a number of scintillators, cross sections were obtained for production of neutrons and gamma-rays. (author)

  16. Treatment of coffee wastewater by gamma radiation

    International Nuclear Information System (INIS)

    Aguilera, Y.; Consuegra, R.; Rapado, M.

    1998-01-01

    Radiation energy can be an important resource in the treatment of wastewaters from different industries both directly and in combination with other processes to improve economics. The aim of this study was to evaluate the effect of an ionizing radiation on coffee wastewater in order to decompose chemical organic refractory substances which cannot be degradated by biological treatment. One of the approaches employed in the survey was the chemical treatment followed by the irradiation of the samples since no nuclear changes of the coagulant solution or wastewater samples were expected. Irradiation is a high cost treatment although it has increased its applications nowadays. The method is safe, fast and effective and it does not generate any pollution

  17. Effects of gamma radiation on fish lipids

    Energy Technology Data Exchange (ETDEWEB)

    Sofyan, R [National Atomic Energy Agency, Jakarta (Indonesia). Pasar Djumat Research Centre

    1982-04-01

    Investigations on the changes of free fatty acid (FFA) value and thiobarbituric acid (TBA) value of fish muscle lipids during chilled storage were carried out. Experimental results showed significant increases in FFA and TBA values during storage. The FFA and TBA values of unirradiated fish were also determined. It was observed that radiation treatments at doses of 2.5 and 5.0 kGy gave no significant effects on FFA values. On the other hand the TBA values of irradiated samples were significantly higher than those of unirradiated samples, indicating that oxidative changes have occured due to radiation. TLC investigations on muscle nonpolar-, phospho- and glycolipids of control and fish samples, irradiated at doses up to 10 kGy revealed that the lipid components or irradiated fish were identical with those of control.

  18. Terrestrial Gamma Radiation Dose Rate of West Sarawak

    Science.gov (United States)

    Izham, A.; Ramli, A. T.; Saridan Wan Hassan, W. M.; Idris, H. N.; Basri, N. A.

    2017-10-01

    A study of terrestrial gamma radiation (TGR) dose rate was conducted in west of Sarawak, covering Kuching, Samarahan, Serian, Sri Aman, and Betong divisions to construct a baseline TGR dose rate level data of the areas. The total area covered was 20,259.2 km2, where in-situ measurements of TGR dose rate were taken using NaI(Tl) scintillation detector Ludlum 19 micro R meter NaI(Tl) approximately 1 meter above ground level. Twenty-nine soil samples were taken across the 5 divisions covering 26 pairings of 9 geological formations and 7 soil types. A hyperpure Germanium detector was then used to find the samples' 238U, 232Th, and 40K radionuclides concentrations producing a correction factor Cf = 0.544. A total of239 measured data were corrected with Cf resulting in a mean Dm of 47 ± 1 nGy h-1, with a range between 5 nGy h-1 - 103 nGy h-1. A multiple regression analysis was conducted between geological means and soil types means against the corrected TGR dose rate Dm, generating Dg,s= 0.847Dg+ 0.637Ds- 22.313 prediction model with a normalized Beta equation of Dg,s= 0.605Dg+ 0.395Ds. The model has an 84.6% acceptance of Whitney- Mann test null hypothesis when tested against the corrected TGR dose rates.

  19. Radiation protection, measurements and methods

    International Nuclear Information System (INIS)

    1983-06-01

    The introductory lectures discuss subjects such as radiation protection principles and appropriate measuring techniques; methods, quantities and units in radiation protection measurement; technical equipment; national and international radiation protection standards. The papers presented at the various sessions deal with: Dosimetry of external radiation (27 papers); Working environment monitoring and emission monitoring (21 contributions); Environmental monitoring (19 papers); Incorporation monitoring (9 papers); Detection limits (4 papers); Non-ionizing radiation, measurement of body dose and biological dosimetry (10 papers). All 94 contributions (lectures, compacts and posters) are retrievable as separate records. (HP) [de

  20. Resistance of Salmonella enteritidis variety typhimurium to gamma radiation

    International Nuclear Information System (INIS)

    Norberg, A.N.; Maliska, C.

    1988-01-01

    The use of ionizing radiations to kill microrganisms responsible for food deterioration, and toxinfections is an example of peaceful use of nuclear energy. Food toxinfections are, amongus, produced mostly by Salmonella enteritidis var. typhimurium. Due to the pauncity of information on the resistance to gamma radiation of Salmonella enteritidis var. typhimurium this paper has the aim to define the 60-Cobalt gamma radiation lethal dose to these bacteria, in experimentally contaminated milk by samples recovered from our geographycal area. One hundred nineteen samples of milk containing about 150.000 bacteria per ml were irradiated with doses ranging from 100 to 1.100 Gy. Two samples of surving bacteria were again irradiated by doses up to 2.500 Gy. The bacteria not previously irradiated were killed by doses of 1.100 Gy. It was concluded that the 60-Cobalt gamma radiation minimal lethal dose to Salmonella enteritidis var. typhimurium is 1.200 Gy. The surviving strains to smaller doses than 1.200 Gy when re-irradiated prompt the forthcoming of more radio-resistant germs. (author) [pt

  1. Recent results on celestial gamma radiation from SMM

    Science.gov (United States)

    Share, Gerald H.

    1991-01-01

    Observations made by the Gamma Ray Spectrometer on board the SMM are described. Recent results reported include observations and analyses of gamma-ray lines from Co-56 produced in supernovae, observations of the temporal variation of the 511 keV line observed during Galactic center transits, and measurements of the diffuse Galactic spectrum from 0.3 to 8.5 MeV. The work in progress includes measurements of the distribution of Galactic Al-26, observations to place limits on Galactic Ti-44 and Fe-60 and on Be-7 produced in novae, and searches for a characteristic gamma-ray emission from pair plasmas, a 2.223 MeV line emission, limits on deexcitation lines from interstellar C and O, and gamma-ray bursts.

  2. Realization of a gamma multiplicity filter and gamma multiplicity measurements

    International Nuclear Information System (INIS)

    Azgui, F.

    1981-12-01

    A gamma multiplicity filter for the study of reaction mechanism has been realised. It's composed of six NaI(Tl) counters. The flexibility of the geometry allows many configurations. This set up has been tested with gamma radioactive sources and with the 252 Cf source to resolve problems of gamma-efficiency of the NaI(Tl) counters and the contamination of neutrons in these detectors. A logical electronic unit (Encodeur) has been constructed and the around electronic has been developped. This gamma multiplicity filter has been coupled with a detector of high resolution Ge(Li), and used in two reactions: 12 C + 55 Mn at E( 12 C) = 54 MeV; α + 63 Cu at E(α) = 52 MeV. The dominant process is the fusion-evaporation. The compound nucleus 67 Ga, is formed at the same excitation energy. The values of multiplicities Msub(γ) have been extracted using a program based on the formalism of W.J. Ockels. The fractionalization of the angular momentum is well observed for some residual nuclei ( 63 Zn, 64 Zn, 65 Zn), and for each residual nucleus, the average gamma multiplicity is lower with projectile α than that with projectile 12 C. For the most strongly output channel p2n, an entry point for the 64 Zn has been determined in the reactions. All these observations are in good agreement with those published, in the same region (f-p shell) of nuclei. This set up can be coupled with different central detector as, ''X'', neutrons charged particles detectors, and will be used with the new machine SARA to make a systematic study of transfer of angular momentum to the fragments at 30 MeV/A [fr

  3. Terrestrial gamma radiation dose rates and radiological mapping of Terengganu state, Malaysia

    International Nuclear Information System (INIS)

    Garba, N.N.

    2015-01-01

    Measurement of terrestrial gamma radiation dose (TGRD) rates in Terengganu state, Malaysia was carried out from 145 different locations using NaI[Tl] micro roentgen survey meter. The measured TGRD rates ranged from 35 to 340 nGy h -1 with mean value of 150 nGy h -1 . The annual effective dose to population was found to be 0.92 mSv y -1 . The data obtained were used in constructing the gamma isodose map using ArcGis 9.3 which shows the distribution of TGRD rates across the state. (author)

  4. Investigation of gamma-ray fingerprint identifying mechanism for the types of radiation sources

    International Nuclear Information System (INIS)

    Liu Suping; Wu Huailong; Gu Dangchang; Gong Jian; Hao Fanhua; Hu Guangchun

    2002-01-01

    Radiation fingerprints sometimes can be used to label and identify the radiation resources. For instance, in a future nuclear reduction treaty that requires verification of irreversible dismantling of reduced nuclear warheads, the radiation fingerprints of nuclear warheads are expected to play a key role in labelling and identifying the reduced warheads. It would promote the development of nuclear warheads deep-cuts verification technologies if authors start right now some investigations on the issues related to the radiation fingerprints. The author dedicated to the investigation of gamma-ray fingerprint identifying mechanism for the types of radiation resources. The purpose of the identifying mechanism investigation is to find a credible way to tell whether any two gamma-ray spectral fingerprints that are under comparison are radiated from the same resource. The authors created the spectrum pattern comparison (SPC) to study the comparability of the two radiation fingerprints. Guided by the principle of SPC, the authors programmed a software dedicated to identify the types of radiation resources. The efficiency of the software was tested by a series of experiments with some laboratory gamma-ray resources. The experiments were designed to look into the relations between comparability and radioactive statistics, and the relations between comparability and some measurement conditions such as real time, resource activity and background etc. Two main results can be drawn from the investigation: 1) it is quite feasible to use the concept of spectral comparability to answer the question whether any two gamma-ray fingerprints are identity or not; 2) the identifying mechanism can only identify the types of radiation resources, and cannot identify the individuals with the same type and small differences

  5. Effect of ionizing radiations on bacterial endotoxins: comparison between gamma radiations and accelerated electrons

    Energy Technology Data Exchange (ETDEWEB)

    Guyomard, S; Goury, V; Darbord, J C

    1988-01-01

    Determinations of the effect of radiation sterilization processing on purified endotoxins, in aqueous solution or on dried support, are reported. These observations allow us to accept gamma radiations for sterilization of parenteral devices with an estimated probability of existence of non apyrogenic items, based upon a similar definition of the usual Sterility Assurance Level (SAL = 10/sup -6/).

  6. Grafting heterogeneous catalyst with gamma radiation

    International Nuclear Information System (INIS)

    Garnett, J.L.; Long, M.A.; Levot, R.G.

    1984-01-01

    A process for the production of a heterogeneous catalyst comprises the steps of: irradiating an organic macromolecular substrate or a metal substrate with ionising or ultra violet radiation in the presence of a monomer selected from the group consisting of o-, m-, or p- styryl diphenyl phosphine and o-, m- or p- phenyl acrylyl diphenyl phosphine, to graft the monomer to the substrate; and reacting the graft copolymer with a homogeneous catalyst selected from the group consisting of catalytic metal salts and catalytic organometallic complexes such that the graft copolymer conjugate becomes a ligand of the catalyst

  7. Underwater radiation measuring device

    International Nuclear Information System (INIS)

    Seki, Noriyuki; Suzuki, Yasuo

    1998-01-01

    The present invention provides a device for measuring, under water, radiation from spent fuels (long members to be detected) of nuclear power plants and reprocessing facilities. Namely, a detecting insertion tube (insertion tube) is disposed so as to be in parallel with axial direction of the long member to be detected stored underwater. A γ-ray detector is inserted to the inside of the insertion tube. A driving mechanism is disposed for moving the γ-ray detector in axial direction inside of the insertion tube. The driving mechanism preferably has a system that it moves the γ-ray detector by winding a detection signal cable around a driving drum. The driving mechanism is formed by inserting and securing a driving tube having screws formed on the side surface and inserting it into the insertion tube. It may have a system of moving the γ-ray detector together with the driving tube while engaging the teeth of a driving transfer mechanism with the screws of the driving tube. (I.S.)

  8. Titanium-Water Thermosyphon Gamma Radiation Exposure and Results

    Science.gov (United States)

    Sanzi, James, L.A; Jaworske, Donald, A.; Goodenow, Debra, A.

    2012-01-01

    Titanium-water thermosyphons are being considered for use in heat rejection systems for fission power systems. Their proximity to the nuclear reactor will result in some gamma irradiation. Noncondensable gas formation from radiation-induced breakdown of water over time may render portions of the thermosyphon condenser inoperable. A series of developmental thermosyphons were operated at nominal operating temperature under accelerated gamma irradiation, with exposures on the same order of magnitude as that expected in 8 years of heat rejection system operation. Temperature data were obtained during exposure at three locations on each thermosyphon: evaporator, condenser, and condenser end cap. Some noncondensable gas was evident; however, thermosyphon performance was not affected because the noncondensable gas was compressed into the fill tube region at the top of the thermosyphon, away from the heat rejecting fin. The trend appeared to be an increasing amount of noncondensable gas formation with increasing gamma irradiation dose. Hydrogen is thought to be the most likely candidate for the noncondensable gas and hydrogen is known to diffuse through grain boundaries. Post-exposure evaluation of one thermosyphon in a vacuum chamber and at temperature revealed that the noncondensable gas diffused out of the thermosyphon over a relatively short period of time. Further research shows a number of experimental and theoretical examples of radiolysis occurring through gamma radiation alone in pure water.

  9. Titanium-Water Thermosyphon Gamma Radiation Effects and Results

    Science.gov (United States)

    Sanzi, James L.; Jaworske, Donald A.; Goodenow, Debra A.

    2012-01-01

    Titanium-water thermosyphons are being considered for use in heat rejection systems for fission power systems. Their proximity to the nuclear reactor will result in some exposure to gamma irradiation. Non-condensable gas formation from radiation may breakdown water over time and render a portion of the thermosyphon condenser inoperable. A series of developmental thermosyphons were operated at nominal operating temperature with accelerated gamma irradiation exposures on the same order of magnitude that is expected in eight years of heat rejection system operation. Temperature data were obtained during exposure at three locations on each thermosyphon; evaporator, condenser, and condenser end cap. Some non-condensable gas was evident, however thermosyphon performance was not affected because the non-condensable gas was compressed into the fill tube region at the top of the thermosyphon, away from the heat rejecting fin. The trend appeared to be an increasing amount of non-condensable gas formation with increasing gamma irradiation dose. Hydrogen is thought to be the most likely candidate for the non-condensable gas and hydrogen is known to diffuse through grain boundaries. Post-exposure evaluation of selected thermosyphons at temperature and in a vacuum chamber revealed that the non-condensable gas likely diffused out of the thermosyphons over a relatively short period of time. Further research shows a number of experimental and theoretical examples of radiolysis occurring through gamma radiation alone in pure water.

  10. X-Ray and Gamma-Ray Radiation Detector

    DEFF Research Database (Denmark)

    2015-01-01

    Disclosed is a semiconductor radiation detector for detecting X-ray and / or gamma-ray radiation. The detector comprises a converter element for converting incident X-ray and gamma-ray photons into electron-hole pairs, at least one cathode, a plurality of detector electrodes arranged with a pitch...... (P) along a first axis, a plurality of drift electrodes, a readout circuitry being configured to read out signals from the plurality of detector electrodes and a processing unit connected to the readout circuitry and being configured to detect an event in the converter element. The readout circuitry...... is further configured to read out signals from the plurality of drift electrodes, and the processing unit is further configured to estimate a location of the event along the first axis by processing signals obtained from both the detector electrodes and the drift electrodes, the location of the event along...

  11. Gamma radiation effects on pequi fruits (Caryocar brasiliense Camb.)

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Marcio Ramatiz L.; Arthur, Valter [Centro de Energia Nuclear na Agricultura (CENA/USP), Piracicaba, SP (Brazil). Lab. de Irradiacao de Alimentos e Radioentomologia], e-mail: mramatiz@eafce.gov.br, e-mail: vaarthur@cena.usp.br; Salgado, Jocelem M.; Spoto, Marta H. Fillet; Canniatti-Brazaca, Solange G. [Universidade de Sao Paulo (USP), Piracicaba, SP (Brazil). Escola Superior de Agricultura Luiz de Queiroz (ESALQ). Dept. de Agroindustria, Alimentos e Nutricao], e-mail: jmsalgad@esalq.usp.br, e-mail: mhfspoto@esalq.usp.br, e-mail: sgcbraza@esalq.usp.br

    2009-07-01

    The objective of this work was to evaluate the effects of gamma radiation on characteristics of pequi fruits (Caryocar brasiliense Camb.). Just now, they are gained attention of researchers due their nutritional properties, between then is the pequi fruits. Fruits come from Goias State was classified, washed and processed to separate the endocarp (edible part) from pericarp. The endocarps were packing in polyethylene bags with 150 g, labeled and submitted to radiation process (0.0, 0.4, 0.6 and 1.0 kGy doses) on multipurpose irradiator located in IPEN/USP. The samples were analyzed to chemical (pH, trititable acidity, deg Brix, ratio TSS/TTA, lipids, ash, humidity, protein, soluble and insoluble fiber, total carotenoids and antioxidant activity) and physical properties (loss weight, texture and color). The irradiation process using gamma rays from Co{sup 60} was effective to protect pequi fruits in postharvest period. (author)

  12. Radiation protection in category III large gamma irradiators

    International Nuclear Information System (INIS)

    Costa, Neivaldo; Furlan, Gilberto Ribeiro; Itepan, Natanael Marcio

    2011-01-01

    This article discusses the advantages of category III large gamma irradiator compared to the others, with emphasis on aspects of radiological protection, in the industrial sector. This category is a kind of irradiators almost unknown to the regulators authorities and the industrial community, despite its simple construction and greater radiation safety intrinsic to the model, able to maintain an efficiency of productivity comparable to those of category IV. Worldwide, there are installed more than 200 category IV irradiators and there is none of a category III irradiator in operation. In a category III gamma irradiator, the source remains fixed in the bottom of the tank, always shielded by water, negating the exposition risk. Taking into account the benefits in relation to radiation safety, the category III large irradiators are highly recommended for industrial, commercial purposes or scientific research. (author)

  13. Gamma radiation effects on pequi fruits (Caryocar brasiliense Camb.)

    International Nuclear Information System (INIS)

    Santos, Marcio Ramatiz L.; Arthur, Valter; Salgado, Jocelem M.; Spoto, Marta H. Fillet; Canniatti-Brazaca, Solange G.

    2009-01-01

    The objective of this work was to evaluate the effects of gamma radiation on characteristics of pequi fruits (Caryocar brasiliense Camb.). Just now, they are gained attention of researchers due their nutritional properties, between then is the pequi fruits. Fruits come from Goias State was classified, washed and processed to separate the endocarp (edible part) from pericarp. The endocarps were packing in polyethylene bags with 150 g, labeled and submitted to radiation process (0.0, 0.4, 0.6 and 1.0 kGy doses) on multipurpose irradiator located in IPEN/USP. The samples were analyzed to chemical (pH, trititable acidity, deg Brix, ratio TSS/TTA, lipids, ash, humidity, protein, soluble and insoluble fiber, total carotenoids and antioxidant activity) and physical properties (loss weight, texture and color). The irradiation process using gamma rays from Co 60 was effective to protect pequi fruits in postharvest period. (author)

  14. Dosimetric studies for gamma radiation validation of medical devices

    International Nuclear Information System (INIS)

    Soliman, Y.S.; Beshir, W.B.; Abdel-Fattah, A.A.; Abdel-Rehim, F.

    2013-01-01

    The delivery and validation of a specified dose to medical devices are key concerns to operators of gamma radiation facilities. The objective of the present study was to characterize the industrial gamma radiation facility and map the dose distribution inside the product-loading pattern during the validation and routine control of the sterilization process using radiochromic films. Cardboard phantoms were designed to achieve the homogeneity of absorbed doses. The uncertainty of the dose delivered during validation of the sterilization process was assessed. - Highlights: ► Using γ-rays for sterilization of hollow fiber dialyzers and blood tubing sets according to ISO 11137, 2006. ► Dosimetry studies of validations of γ-irradiation facility and sterilized medical devices. ► Places of D min and D max have been determined using FWT-60 films. ► Determining the target minimum doses required to meet the desired SAL of 10 −6 for the two products.

  15. Slaughterhouse sewage treatment using gamma radiation - economical feasibility study

    International Nuclear Information System (INIS)

    Melo, Rita; Botelho, M. Luisa; Branco, Joaquim

    2005-01-01

    This paper presents preliminary results of a financial viability study for the implementation of gamma radiation technology on a slaughterhouse wastewater treatment industry. Five scenarios were studied, including the current practice, representing different types of treatments and goals, e.g.: water reuse and/or sludge add value as agriculture fertilizers. Cost-benefit analysis, including the net present value (NPV) of each scenario, was used as a technique to compare the relative value of various strategies. Taking in account that the initial investment is amortized after 20 years, the implementation of Co-60 treatment with 20% water reuse and sludge application as agriculture fertilizers represents the most profitable project with the highest NPV. Therefore, the implementation of gamma radiation technology on a slaughterhouse wastewater treatment industry is not only technically viable as well as economically feasible. (author)

  16. Gamma radiation in pest control at the storehouses

    International Nuclear Information System (INIS)

    Tsvetkov, D.; Atanasov, Khr.; Berberov, D.

    1974-01-01

    The prospects of radiation control of wheat grain pests in Bulgaria are shown, drawing the following main conclusions: The lethal doses of gamma rays for the granary weevil, grain borer and confused flour beetle are fairly high - of the order of 300,000-400,000 r; the sterilizing doses of gamma rays arrest the reproduction of granary and rice weevils as well as of confused flour beetles. The irradiated insects, however, retain their sex activity and so may inhibit the reproduction of fertile populations. Irradiation strongly reduces the life span of, and consequently the damage done by, the insects; radiation control of stored-grain pests by using sterilizing doses does not deteriorate the technological quality of the wheat grain. (E.T.)

  17. Effects of chronic gamma radiation on the lichen Parmelia sulcata Tayl. in the Enterprise Radiation Forest

    International Nuclear Information System (INIS)

    Erbisch, F.H.

    1977-01-01

    Within the Enterprise Radiation Forest, the foliose lichen Parmelia sulcata Tayl. exhibited radiation damage. Only those lichens which received in excess of 100 krad manifested damage. The damage was evidenced as a lifting and subsequent breaking of lobes, a coalescing of fungal hyphae, a formation of a brown pigment by the coalescing hyphae, a distortion of the chloroplastid of the algal component, and eventual death of the lichen. The radiation also affected thallus growth by slowing it and rhizinae branching by increasing the number of branches. Damage was not manifested until the late spring (June) of the year following radiation. Apparently P. sulcata is able to maintain itself until conditions are favorable for growth, after receiving a large dose of gamma radiation. Under favorable growth conditions, the lichen cannot carry out its normal growth functions and deteriorates. Although environmental changes did occur within the forest, evidence obtained indicates that gamma radiation was the principal factor affecting the lichens

  18. Effects of gamma radiation on snake venoms

    International Nuclear Information System (INIS)

    Nascimento, N.; Spencer, P.J.; Andrade, H.F.; Guarnieri, M.C.; Rogero, J.R.

    1998-01-01

    Ionizing radiation is able to detoxify several venoms, including snake venoms, without affecting significantly their immunogenic properties. In order to elucidate this phenomena, we conceived a comparative pharmacological study between native and irradiated (2,000 Gy) crotoxin, the main toxin of the South American rattlesnake Crotalus durissus terrificus. Crotoxin was isolated and purified by molecular exclusion chromatography, pI precipitation and, subsequently submitted to irradiation. Gel filtration of the irradiated toxin resulted in some high molecular weight aggregates formation. Crotoxin toxicity decreased two folds after irradiation, as determined by LD 50 in mice. Native and irradiated crotoxin biodistribution ocurred in the same general manner, with renal elimination. However, in contrast to irradiated crotoxin, the native form was initially retained in kidneys. A later concentration (2-3 hr) appeared in phagocytic mononuclear cells rich organs (liver and spleen) and neural junction rich organs (muscle and brain)

  19. Attenuation of gamma radiation in concrete shields

    International Nuclear Information System (INIS)

    Azevedo e Souza, A.C. de.

    1978-12-01

    The attenuation characteristics of γ radiation in concrete layers considering their mechanical resistence and densities were determined. A 137 Cs source was used in a 'good geometry' arrangement to eliminate the effects of the buildup factor. The ordinary and the heavy concrete were irradiated and for the latter it was used as additives iron ore and Fe 2 O 3 pellets in various grain sizes. The detection system consisted of a 2' x 2' NaI (Tl) crystal coupled to a photomultiplier tube and the associated electronic equipment. FORTRAN programs were used for determining the absorption coefficients and the attenuation factors. These programs calculate photopeak areas eliminating all contributions due to Compton effect and background. (Author) [pt

  20. Operational experience of gamma radiation processing facility

    International Nuclear Information System (INIS)

    Patel, Nilesh

    2014-01-01

    Universal lSO-MED is now proud to announce an extension of its irradiation service for low-dose applications specifically in agriculture commodities, food and healthcare applications with the start of Gujarat Agro Radiation Processing Facility at Village: Bavla, Ahmedabad (A Government Enterprise) Operated, Maintained and Managed by Universal Medicap Ltd. Availability of hygienic, safe and nutritious food commodities is essential for any sustainable human development. Food stability is an important element of economic stability and self-reliance of a nation. Though the need to preserve food has been felt by the mankind since the time immemorial, it is even stronger in today's context. The rising population and increasing gap between demand and supply, agro-climatic conditions, in adequate post-harvest practices, seasonal nature of produce and long distances between production and consumption centers underscore the need to device improved conservation and preservation strategies

  1. Evaluation of genotoxicity of the acute gamma radiation on earthworm Eisenia fetida using single cell gel electrophoresis technique (Comet assay).

    Science.gov (United States)

    Sowmithra, K; Shetty, N J; Jha, S K; Chaubey, R C

    2015-12-01

    Earthworms (Eisenia fetida) most suitable biological indicators of radioactive pollution. Radiation-induced lesions in DNA can be considered to be molecular markers for early effects of ionizing radiation. Gamma radiation produces a wide spectrum of DNA. Some of these lesions, i.e., DNA strand breaks and alkali labile sites can be detected by the single-cell gel electrophoresis (SCGE) or comet assay by measuring the migration of DNA from immobilized nuclear DNA. E. fetida were exposed to different doses of gamma radiation, i.e., 1, 5, 10, 20, 30, 40 and 50Gy, and comet assay was performed for all the doses along with control at 1, 3 and 5h post irradiation to evaluate the genotoxicity of gamma radiation in this organism. The DNA damage was measured as percentage of comet tail DNA. A significant increase in DNA damage was observed in samples exposed to 5Gy and above, and the increase in DNA damage was dose dependent i.e., DNA damage was increased with increased doses of radiation. The highest DNA damage was noticed at 1h post irradiation and gradually decreased with time, i.e., at 3 and 5h post irradiation. The present study reveals that gamma radiation induces DNA damage in E. fetida and the comet assay is a sensitive and rapid method for its detection to detect genotoxicity of gamma radiation. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Gamma-radiation effect on diamond and steel during their irradiation in WWER type reactors

    International Nuclear Information System (INIS)

    Nikolaenko, V.A.; Karpukhin, V.I.; Amaev, A.D.; Vikhrov, V.I.; Korolev, Yu.N.; Krasikov, E.A.

    1996-01-01

    A study is made into the influence of reactor gamma radiation on expansion of crystal lattice in diamond. The data obtained are compared to those on radiation embrittlement of reactor vessel steels. The necessity of taking into consideration gamma radiation effects on WWER reactor vessel radiation resistance during long-term operation is shown [ru

  3. Assessment of environmental gamma radiation levels at locations having different source characteristics using TLDs

    International Nuclear Information System (INIS)

    Sahu, S.K.; Swarnkar, M.; Takale, R.A.; Shetty, P.G.; Pandit, G.G.; Puranik, V.D.

    2012-01-01

    Naturally occurring radionuclides are the major contributor to the total effective dose of ionizing radiation received by the population (UNSCEAR, 1993). The dose in environment thus depends largely on natural radiation than manmade or artificially produced radiation. In the last few decades, there is a growing concern all over the world about radiation and their exposure to population. Thus, it is a necessity to conduct frequent radiological environmental surveillance in order to assess population exposure accurately. Recently, application of thermoluminescence dosimeters (TLDs) has been extended to the measurement of mixed radiation field as encountered in the environment. The advantages of passive TL dosimeters for environmental monitoring are that they are small, cheap and do not require power supply during application. The passive TL dosimeters play an important role to provide data on natural background radiation and to determine the contribution to the dose to public from man-made sources. In the present study, three different sites were chosen to compare environmental gamma radiation levels in different scenarios. Kaiga has been chosen as site 1, where four unit of pressurized heavy water reactor (PHWR) of 220 MWe each are in operation. Site 2 is chosen at natural high background radiation area (NHBRA) of Kerala and Vishakhapatnam was chosen as site 3, which is situated at a normal background area. The objective of the study is to illustrate the effect, if any, of an operating nuclear power reactor on environmental gamma radiation levels

  4. The role of contacts in semiconductor gamma radiation detectors

    International Nuclear Information System (INIS)

    Lachish, U.

    1998-01-01

    It is proposed that the operation of semiconductor gamma radiation detectors, equipped with ohmic contacts, which allow free electron flow between the contacts and bulk material, will not be sensitive to low hole mobility, hole collection efficiency, or hole trapping. Such fast-operating detectors may be readily integrated into monolithic arrays. The detection mechanism and various material aspects are discussed and compared to those of blocking contact detectors. Some suggestions for detector realization are presented. (orig.)

  5. Pharmaceutical aerosols. Study of their gamma radiation sterilization

    International Nuclear Information System (INIS)

    Sebert, P.

    1984-10-01

    The gamma radiation sterilization of pharmaceutical aerosols was studied. The following topics were investigated: radiosterilization of nitrogen protoxide used as a propellant; radiosterilization of packaging materials (aluminium containers, plastics valves); radio-sterilization of excipients and active ingredients. Most of the investigated materials proved to be stable to irradiation (2,5 Mrads) from pharmacopoeial aspect. Stability tests of the preparations packaged showed no change in the parameters investigated [fr

  6. Composting of gamma-radiation disinfected sewage sludge

    International Nuclear Information System (INIS)

    Kawakami, W.; Hashimoto, S.; Watanabe, H.; Nishimura, K.; Watanabe, H.; Ito, H.; Takehisa, M.

    1981-01-01

    The composting of radiation disinfected sewage sludge has been studied since 1978, aiming to present a new process of sludge composting for agricultural uses. This process is composed of two steps: irradiation step to disinfect sludge, and composting step to remove odor and easily decomposable organics in sludge. In this paper, the gamma-irradiation effect on sludge cake and composting condition of irradiated sludge are discussed. (author)

  7. The electric charge of the aerosols under gamma radiation

    International Nuclear Information System (INIS)

    Gensdarmes, F.; Cetier, P.; Boulaud, D.; Gensdarmes, F.; Renoux, A.

    2000-01-01

    During a PWR type reactor accident, the gamma radiation may create a high ionized atmosphere. In such a situation the aerosols properties knowledge is useful to simulate the particles transport and deposit in the enclosed. The aim of this study is to determine the aerosol charges distribution in a high ionized medium, in function of the ionic properties of the medium. (A.L.B.)

  8. Gamma model and its analysis for phase measuring profilometry.

    Science.gov (United States)

    Liu, Kai; Wang, Yongchang; Lau, Daniel L; Hao, Qi; Hassebrook, Laurence G

    2010-03-01

    Phase measuring profilometry is a method of structured light illumination whose three-dimensional reconstructions are susceptible to error from nonunitary gamma in the associated optical devices. While the effects of this distortion diminish with an increasing number of employed phase-shifted patterns, gamma distortion may be unavoidable in real-time systems where the number of projected patterns is limited by the presence of target motion. A mathematical model is developed for predicting the effects of nonunitary gamma on phase measuring profilometry, while also introducing an accurate gamma calibration method and two strategies for minimizing gamma's effect on phase determination. These phase correction strategies include phase corrections with and without gamma calibration. With the reduction in noise, for three-step phase measuring profilometry, analysis of the root mean squared error of the corrected phase will show a 60x reduction in phase error when the proposed gamma calibration is performed versus 33x reduction without calibration.

  9. Corrosion of copper-based materials in gamma radiation

    International Nuclear Information System (INIS)

    Yunker, W.H.

    1986-06-01

    The corrosion behaviors of pure copper (CDA 101), 7% aluminum-copper bronze (CDA 613) and 30% nickel-copper (CDA 715) are being studied in a gamma radiation field of 1 x 10 5 R/h. These studies are in support of the Nevada Nuclear Waste Storage Investigations (NNWSI) Project, by Lawrence Livermore National Laboratory (LLNL), of copper-based materials for possible use in container systems for the permanent geologic burial of nuclear waste. Weight loss, tear drop (stressed), and crevice specimens of the three materials were exposed to water vapor-air atmospheres at 95 0 C and 150 0 C and to liquid water at 95 0 C for periods of one, three, and six months. Longer exposures are in progress. Measurements include: changes in the chemical composition of the gas and water, specimen weight changes, oxide film weights, evidence of microcracking and crevice corrosion, and chemical composition of the oxide films by Auger electron spectroscopy and x-ray diffraction. Interim results show considerable pit and under-film corrosion of alloys CDA 613 and CDA 715. Uniform corrosion rates range from 0.012 mil/yr (0.30 μm/yr) to 0.22 mil/yr (5.6 μm/yr), based on specimen weight losses during six- and seven-month exposures. The time dependencies will be determined as more data become available

  10. Gamma radiation in the control of insects in animal feed

    Energy Technology Data Exchange (ETDEWEB)

    Arthur, Paula B.; Arthur, Valter; Silva, Lucia C.A.S.; Franco, Suely S.H., E-mail: paula.arthur@hotmail.com, E-mail: arthur@cena.usp.br [Centro de Energia Nuclear na Agricultura (CENA/USP), Piracicaba, SP (Brazil); Franco, Jose G.; Villavicencio, Anna Lucia, E-mail: gilmita@uol.com.br, E-mail: villavic@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Harder, Marcia N.C., E-mail: marcia.harder@fatec.sp.gov.br [Centro Paula Souza, Curso Superior de Tecnologia em Biocombustiveis (FATEC), Piracicaba, SP (Brazil)

    2015-07-01

    The pests as beetles, acarids, moths and mushrooms among other, usually infest products stored as: grains, crumbs, flours, coffee, tobacco, dried fruits, animal feeds, spices and dehydrated plants, causing the visual depreciation and promoting the deterioration of the products. The objective of this study was to use gamma radiation of Cobalt-60 in the disinfestation of some types of commercial feeds used for animals of small size. In the experiment, packages measuring 10 cm x 15 cm, with capacity of 30 grams of substrate with 4 types of trademarks were irradiated with doses of: 0 (control) 0.5; 1.0 and 2.0 kGy. Each treatment had 10 repetitions, infested with 10 insects for each package with the following species: Lasioderma serricorne, Plodia interpuctella, Sitophilus zeamais and S. oryzae. After the irradiation, all the packages were maintained at acclimatized room with 27 ± 2ºC and relative humidity of 70 ± 5%. The number of insects and holes in all packages were assessed after 60 days. The results showed that the dose of 0.5 kGy was sufficient to control all the species of insects in the tested feeds. (author)

  11. Gamma radiation in the control of insects in animal feed

    International Nuclear Information System (INIS)

    Arthur, Paula B.; Arthur, Valter; Silva, Lucia C.A.S.; Franco, Suely S.H.; Franco, Jose G.; Villavicencio, Anna Lucia; Harder, Marcia N.C.

    2015-01-01

    The pests as beetles, acarids, moths and mushrooms among other, usually infest products stored as: grains, crumbs, flours, coffee, tobacco, dried fruits, animal feeds, spices and dehydrated plants, causing the visual depreciation and promoting the deterioration of the products. The objective of this study was to use gamma radiation of Cobalt-60 in the disinfestation of some types of commercial feeds used for animals of small size. In the experiment, packages measuring 10 cm x 15 cm, with capacity of 30 grams of substrate with 4 types of trademarks were irradiated with doses of: 0 (control) 0.5; 1.0 and 2.0 kGy. Each treatment had 10 repetitions, infested with 10 insects for each package with the following species: Lasioderma serricorne, Plodia interpuctella, Sitophilus zeamais and S. oryzae. After the irradiation, all the packages were maintained at acclimatized room with 27 ± 2ºC and relative humidity of 70 ± 5%. The number of insects and holes in all packages were assessed after 60 days. The results showed that the dose of 0.5 kGy was sufficient to control all the species of insects in the tested feeds. (author)

  12. ''Intelligent'' radiation measurements

    International Nuclear Information System (INIS)

    Ward, A.

    1980-01-01

    A description is given of three applications of current microprocessor technology which are characterized by the use of the microprocessor to impart a degree of intelligence to conventional radiation detection techniques. In the first application the microcomputer computes the radiation dose from the observed counting rate in a Geiger counter. In the second application the microcomputer provides the pulse height distribution and the radioisotopes used, from the spectrum of pulses from a scintillation counter. The third application is an arrangement for radiation monitor calibration. (H.K.)

  13. Estimation of the terrestrial gamma-ray levels from car-borne measurements

    International Nuclear Information System (INIS)

    Badran, H.M.

    1998-01-01

    A place to place variation of the gamma-radiation has been measured. The terrestrial gamma-ray levels were obtained with a portable Nal(Tl) detector. Gamma-ray levels were measured inside a car for a distance of about 220 km, from Norman up to Tulsa, Oklahoma, USA. Simultaneous measurements have also been carried out outside the vehicle and at distances 1 m and 5 m from the car. A series of data was collected every 1 mile (∼ 1.6 km). The measurements were also repeated different time under different conditions. The measured car-borne levels were correlated with the outdoor equivalent levels at 1 m above flat ground. The result permits a good estimation of the outdoor gamma-ray levels from the car measurements after the correction due to the vehicle shielding

  14. Effect of Gamma Radiation on Quality of Imitation Crab Meat

    International Nuclear Information System (INIS)

    Charoen, Saovapong; Sajjabut, Surasak

    2007-08-01

    Full text: Irradiation at 0.5, 1.0 and 1.5 kGy of some commercial imitation crab meats with non-vacuum packaging reduced the total viable count by 1-2 log cycles, while coliform and Staphylococcus aureus were eliminated by 1.5 kGy gamma radiation. Although TBA number of 1 and 1.5 kGy irradiated samples increased significantly, but the sensory evaluation did not show any significant differences compared with the controls. Radiation dosage of 1.5 kGy appeared to be sufficient for improving bacterial quality and eliminating coliform and Staphylococcus aureus

  15. The induced radioactivity danger parameter for gamma radiation

    International Nuclear Information System (INIS)

    Perry, D.R.

    1985-07-01

    Dosimetric and practical aspects of the induced radioactivity danger parameter, as used for calculating the gamma radiation dose rate near to objects that have been exposed to high energy radiation, are examined. A simplified and more generally applicable method of calculation is proposed, based on energy balance in homogeneous media. The problems of applying this in practice are discussed, and it is shown that corrections are generally small enough to be neglected in many practical applications. Examples of calculations by previous and proposed methods are given. (author)

  16. Influence of gamma radiation onto polymeric matrix with papain

    International Nuclear Information System (INIS)

    Zulli, Gislaine; Lopes, Patricia Santos; Velasco, Maria Valeria Robles; Alcantara, Mara Tania Silva; Rogero, Sizue Ota; Lugao, Ademar Benevolo; Mathor, Monica Beatriz

    2010-01-01

    Papain is a proteolytic enzyme that has been widely used as debridement agent for scars and wound healing treatment. However, papain presents low stability, which limits its use to extemporaneous or short shelf-life formulations. The purpose of this study was to entrap papain into a polymeric matrix in order to obtain a drug delivery system that could be used as medical device. Since these systems must be sterile, gamma radiation is an interesting option and presents advantages in relation to conventional agents: no radioactive residues are formed; the product can be sterilized inside the final packaging and has an excellent reliability. The normative reference for the establishment of the sterilizing dose determines 25 kGy as the inactivation dose for viable microorganisms. A silicone dispersion was selected to prepare membranes containing 2% (w/w) papain. Irradiated and non-irradiated membranes were simultaneously assessed in order to verify whether gamma radiation interferes with the drug-releasing profile. Results showed that irradiation does not affect significantly papain release and its activity. Therefore papain shows radioresistance in the irradiation conditions applied. In conclusion, gamma radiation can be easily used as sterilizing agent without affecting the papain release profile and its activity onto the biocompatible device is studied.

  17. Inactivation of bacteria in sewage sludge by gamma radiation

    International Nuclear Information System (INIS)

    Pandya, G.A.; Kapila, Smita; Kelkar, V.B.; Negi, Shobha; Modi, V.V.

    1987-01-01

    The survival of certain bacterial cultures suspended in sewage sludge and exposed to gamma-radiation was studied. The inactivation patterns of most of the organisms were significantly different when irradiation was performed using sewage samples collected in the summer and monsoon seasons. The summer sample collected from the anaerobic digester afforded significant protection to both Gram negative and Gram positive organisms. This was evident by the increase in dose required to bring about a 6 log cycle reduction in viable count of the bacterial cultures, when suspended in sewage samples instead of phosphate buffer. The observations made using monsoon digester samples were quite different. This sewage sludge greatly enhanced inactivation by gamma-radiation in most cases. The effects of certain chemicals on the inactivation patterns of two organisms - Salmonella typhi and Shigella flexneri - were examined. Arsenate, mercury and lead salts sensitised S. typhi, while barium acetate and sodium sulphide protected this culture against gamma-radiation. In the case of Sh. flexneri, barium acetate and iodacetamide proved to be radioprotectors. The effects of some chemicals on the inactivation pattern of Sh. flexneri cells irradiated in sludge are also discussed. (author)

  18. Influence of gamma radiation onto polymeric matrix with papain

    Energy Technology Data Exchange (ETDEWEB)

    Zulli, Gislaine [Nuclear and Energetic Research Institute, IPEN-CNEN/SP, Sao Paulo, SP 05508-000 (Brazil); Lopes, Patricia Santos, E-mail: patricia.lopes@prof.uniso.b [Pharmacy Department, University of Sorocaba, Sorocaba, SP 18023-000 (Brazil); Velasco, Maria Valeria Robles [Pharmacy Department, University of Sao Paulo, Sao Paulo, SP 05508-900 (Brazil); Alcantara, Mara Tania Silva; Rogero, Sizue Ota; Lugao, Ademar Benevolo; Mathor, Monica Beatriz [Nuclear and Energetic Research Institute, IPEN-CNEN/SP, Sao Paulo, SP 05508-000 (Brazil)

    2010-03-15

    Papain is a proteolytic enzyme that has been widely used as debridement agent for scars and wound healing treatment. However, papain presents low stability, which limits its use to extemporaneous or short shelf-life formulations. The purpose of this study was to entrap papain into a polymeric matrix in order to obtain a drug delivery system that could be used as medical device. Since these systems must be sterile, gamma radiation is an interesting option and presents advantages in relation to conventional agents: no radioactive residues are formed; the product can be sterilized inside the final packaging and has an excellent reliability. The normative reference for the establishment of the sterilizing dose determines 25 kGy as the inactivation dose for viable microorganisms. A silicone dispersion was selected to prepare membranes containing 2% (w/w) papain. Irradiated and non-irradiated membranes were simultaneously assessed in order to verify whether gamma radiation interferes with the drug-releasing profile. Results showed that irradiation does not affect significantly papain release and its activity. Therefore papain shows radioresistance in the irradiation conditions applied. In conclusion, gamma radiation can be easily used as sterilizing agent without affecting the papain release profile and its activity onto the biocompatible device is studied.

  19. Influence of gamma radiation onto polymeric matrix with papain

    Science.gov (United States)

    Zulli, Gislaine; Lopes, Patrícia Santos; Velasco, Maria Valéria Robles; Alcântara, Mara Tânia Silva; Rogero, Sizue Ota; Lugao, Ademar Benévolo; Mathor, Monica Beatriz

    2010-03-01

    Papain is a proteolytic enzyme that has been widely used as debridement agent for scars and wound healing treatment. However, papain presents low stability, which limits its use to extemporaneous or short shelf-life formulations. The purpose of this study was to entrap papain into a polymeric matrix in order to obtain a drug delivery system that could be used as medical device. Since these systems must be sterile, gamma radiation is an interesting option and presents advantages in relation to conventional agents: no radioactive residues are formed; the product can be sterilized inside the final packaging and has an excellent reliability. The normative reference for the establishment of the sterilizing dose determines 25 kGy as the inactivation dose for viable microorganisms. A silicone dispersion was selected to prepare membranes containing 2% (w/w) papain. Irradiated and non-irradiated membranes were simultaneously assessed in order to verify whether gamma radiation interferes with the drug-releasing profile. Results showed that irradiation does not affect significantly papain release and its activity. Therefore papain shows radioresistance in the irradiation conditions applied. In conclusion, gamma radiation can be easily used as sterilizing agent without affecting the papain release profile and its activity onto the biocompatible device is studied.

  20. Application of the similitude principle to gamma-gamma density measurements; Application du principe de similitude a la mesure gamma-gamma de densite

    Energy Technology Data Exchange (ETDEWEB)

    Czubek, J A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires. Departement d' Electronique Generale, Service d' Electronique Industrielle; Institut de Recherches Nucleaires, Dep. VI, Cracow (Poland)

    1966-07-01

    The work presented here deals with the problem of the application of the similitude principle to rock density measurements by the gamma-gamma method. A formula is presented which makes it possible to transform results of gamma-gamma measurements carried out on models in order to make them suitable for comparison with results obtained under actual field conditions. Both the space coordinates and the densities are transformed. This transformation makes it possible to obtain a calibration curve as a function of the density for a gamma-gamma probe using only a single model of given density. The influence has also been studied of the chemical composition on the results obtained from gamma-gamma measurements. A method has been developed for estimating the equivalent Z parameter of the medium; the possibility of completely eliminating the influence of the chemical composition of the medium on the measurement results has been studied. (author) [French] L'etude presentee ci-dessous traite le probleme de l'application du principe de similitude aux mesures de densite des roches par la methode gamma-gamma. Nous indiquons une formule qui permet de transformer les resultats des mesures gamma-gamma effectuees sur les modeles pour les comparer aux resultats obtenus dans les conditions reelles sur le terrain. On transforme les coordonnees spatiales ainsi que les densites. Cette transformation donne la possibilite d'obtenir une courbe d'etalonnage (en fonction de la densite) pour une sonde gamma-gamma en utilisant un seul modele de densite donnee. On a etudie aussi l'influence de la composition chimique sur les resultats obtenus des mesures gamma-gamma. On a etabli une methode d'estimation du parametre Z equivalent du milieu, ainsi que la possibilite d'eliminer completement l'influence de la composition chimique du milieu sur les resultats des mesures de densite. (auteur)

  1. The Measuring of the Gamma Dose Rate in the Air at Location of the Sar-Mountain

    International Nuclear Information System (INIS)

    Adrovic, F.; Ninkovic, M.; Adrovic, S.

    1999-01-01

    The results of the measured values of gamma dose rate in the air at the location of Sar-mountain (Balkan Peninsula) using autonomous ADL-probe Gamma Tracer system. The difference between levels of the natural background radiation and natural environment has been pointed out at the different chosen measuring overall research of natural radioactivity at the location of Sar-mountain

  2. Development of radiation protection and measurement technology

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Si Young; Lee, T. Y.; Kim, J. L.; Kim, B. H.; Lee, B. J.; Chung, K. K.; Lee, K. C.; Chung, R. I.; Han, Y. D.; Kim, J. S.; Lee, H. S.; Kim, C. K.; Yoon, K. S.; Jeong, D. Y.; Yoon, S. C.; Yoon, Y. C.; Lee, S. Y.; Kim, J. S.; Seo, K. W. [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of); Kim, J. K.; Lee, J. K. [Hanyang Univ., Seoul (Korea, Republic of)

    1997-07-01

    Reference X-, gamma, beta and neutron radiation fields complying with the ISO and ANSI standards have been established and evaluated to provide a basic technical support in national radiation protection dosimetry program and to provide calibration measurement devices. Personal dose evaluation algorithm has been developed with these reference radiation fields, which comply well with both domestic and the new ANSI N13.11, to evaluate accurate personal dose equivalents. A personal internal dosimetry algorithm which can estimate the intakes of radionuclides from the results of in vivo bioassay and the resulting internal doses has been developed and verified its performance. It was also evaluated to be equality excellent compared with those being used in foreign countries and used to make a computer code for internal dose evaluation which can be run with PC under the Windows environment. A BOMAB phantom for precise calibration of in vivo system has been also designed, fabricated and test-evaluated. Based on the ALARA concept of the optimization principle of radiation protection, a method for estimating the cost for radiation protection has been studied and an objective monetary cost of detriment due to radiation exposure, called {alpha} value ($/man-Sv) has been derived and proposed based on the Korean socio-economic situation and human risk factors to provide basic data for the radiation protection optimization study in Korea. (author). 100 refs., 104 tabs., 69 figs.

  3. Measurements of anisotropy in the cosmic microwave background radiation at 0.5 deg angular scales near the star gamma ursae minoris

    Science.gov (United States)

    Devlin, M. J.; Clapp, A. C.; Gundersen, J. O.; Hagmann, C. A.; Hristov, V. V.; Lange, A. E.; Lim, M. A.; Lubin, P. M.; Mauskopf, P. D.; Meinhold, P. R.

    1994-01-01

    We present results from a four-frequency observation of a 6 deg x 0.6 deg strip of the sky centered near the star Gamma Ursae Minoris (GUM) during the fourth flight of the Millimeter-wave Anistropy experiment(MAX). The observation was made with a 1.4 deg peak-to-peak sinusoidal chop in all bands. The FWHM beam sizes were 0.55 deg +/- 0.05 deg at 3.5 per cm and 0.75 deg +/- 0.05 deg at 6, 9, and 14 per cm. During this observation significant correlated structure was observed at 3.5, 6 and 9 per cm with amplitudes similar to those observed in the GUM region during the second and third fligts of MAX. The frequency spectrum is consistent with cosmic microwave background (CMB) and inconsistent with thermal emission from interstellar dust. The extrapolated amplitudes of synchrotron and free-free emission are too small to account for the amplitude of the observed structure, If all of the structure is attributed to CMB anisotropy with a Gaussian autocorrelation function and a coherence angle of 25 min, then the most probable values of delta T/T(sub CMB) in the 3.5, 6 and 9 per cm bads are (4.3 +2.7/-1.6) x 10(exp -5), 2.8 (+4.3/-1/1) x 10(exp -5), and 3.5 (+3.0/-1.6) x 10(exp -5) (95% confidence upper and lower limits), respectively.

  4. Effect of gamma-radiation on sugar cane spirit

    International Nuclear Information System (INIS)

    Souza, Maria Djiliah Camargo Alvarenga de

    2000-01-01

    Irradiation has appeared as an alternative technique in food preservation. Besides cold decontamination irradiation can increase the quality of the food through the improvement of technological properties. For alcoholic beverages ionizing radiation has been applied to wines, whiskeys and beers in countries such as Thailand and China. In those cases, the purpose of the technique was to accelerate aging, to improve the sensory characteristics and as sterilization treatment. The aim of this work was to study the effect of gamma radiation on the quality of sugar cane spirit by gas chromatography analysis of volatile compounds and sensory analysis. The sugar cane spirit newly distilled samples and commercial samples from different states (SP, CE and RJ) were irradiated either in glass or oak cask (Quercus alba sp) in a 60 Co Gammacell 220 at dose rate of 7.7 kGy/h and total doses of 0; 0.1; 2; 5 and 10 kGy. The analytical determination of esters, acetaldehyde and higher alcohols were performed in a gas chromatograph with flame ionization detector employing a Megabore CG-745 column. The alcoholic graduation was measured in a Gay-Lussac alcohometer and the pH was determined using an Analyser 300 pHmeter. The color change was measured by the absorbance at 420 nm in a Shimadzu UV 1601 spectrophotometer. The acceptance tests related to odor, taste, global impression and color were analyzed using Tukey average tests (p ≤0,05), ANOVA and histograms of panelists' scores frequency. A correlation between acetaldeyde, esters, higher alcohols levels and radiation dose was found in the sugar cane spirit newly distilled samples irradiated in oak cask and commercial samples. An increase in methanol concentration was verified, although remaining enough below the permissible limit accepted by the Brazilian Legislation. A decrease in the alcoholic graduation and pH in the irradiated samples was observed. A slight discoloration in the irradiated samples was verified. According to ANOVA

  5. Measurement of the ratio of branching fractions ${\\cal B}(B^0 \\to K^{\\ast 0} \\gamma)/{\\cal B}(B^0_s \\to \\phi \\gamma)$

    CERN Document Server

    Aaij, R; Adeva, B; Adinolfi, M; Adrover, C; Affolder, A; Ajaltouni, Z; Albrecht, J; Alessio, F; Alexander, M; Alkhazov, G; Alvarez Cartelle, P; Alves Jr, A A; Amato, S; Amhis, Y; Anderson, J; Appleby, R B; Aquines Gutierrez, O; Archilli, F; Arrabito, L; Artamonov, A; Artuso, M; Aslanides, E; Auriemma, G; Bachmann, S; Back, J J; Bailey, D S; Balagura, V; Baldini, W; Barlow, R J; Barschel, C; Barsuk, S; Barter, W; Bates, A; Bauer, C; Bauer, Th; Bay, A; Bediaga, I; Belogurov, S; Belous, K; Belyaev, I; Ben-Haim, E; Benayoun, M; Bencivenni, G; Benson, S; Benton, J; Bernet, R; Bettler, M -O; van Beuzekom, M; Bien, A; Bifani, S; Bird, T; Bizzeti, A; Bjørnstad, P M; Blake, T; Blanc, F; Blanks, C; Blouw, J; Blusk, S; Bobrov, A; Bocci, V; Bondar, A; Bondar, N; Bonivento, W; Borghi, S; Borgia, A; Bowcock, T J V; Bozzi, C; Brambach, T; van den Brand, J; Bressieux, J; Brett, D; Britsch, M; Britton, T; Brook, N H; Brown, H; Büchler-Germann, A; Burducea, I; Bursche, A; Buytaert, J; Cadeddu, S; Callot, O; Calvi, M; Calvo Gomez, M; Camboni, A; Campana, P; Carbone, A; Carboni, G; Cardinale, R; Cardini, A; Carson, L; Carvalho Akiba, K; Casse, G; Cattaneo, M; Cauet, Ch; Charles, M; Charpentier, Ph; Chiapolini, N; Ciba, K; Cid Vidal, X; Ciezarek, G; Clarke, P E L; Clemencic, M; Cliff, H V; Closier, J; Coca, C; Coco, V; Cogan, J; Collins, P; Comerma-Montells, A; Constantin, F; Contu, A; Cook, A; Coombes, M; Corti, G; Couturier, B; Cowan, G A; Currie, R; D'Ambrosio, C; David, P; David, P N Y; De Bonis, I; De Bruyn, K; De Capua, S; De Cian, M; De Lorenzi, F; De Miranda, J M; De Paula, L; De Simone, P; Decamp, D; Deckenhoff, M; Degaudenzi, H; Del Buono, L; Deplano, C; Derkach, D; Deschamps, O; Dettori, F; Dickens, J; Dijkstra, H; Diniz Batista, P; Domingo Bonal, F; Donleavy, S; Dordei, F; Dosil Suárez, A; Dossett, D; Dovbnya, A; Dupertuis, F; Dzhelyadin, R; Dziurda, A; Easo, S; Egede, U; Egorychev, V; Eidelman, S; van Eijk, D; Eisele, F; Eisenhardt, S; Ekelhof, R; Eklund, L; Elsasser, Ch; Elsby, D; Esperante Pereira, D; Falabella, A; Fanchini, E; Färber, C; Fardell, G; Farinelli, C; Farry, S; Fave, V; Fernandez Albor, V; Ferro-Luzzi, M; Filippov, S; Fitzpatrick, C; Fontana, M; Fontanelli, F; Forty, R; Francisco, O; Frank, M; Frei, C; Frosini, M; Furcas, S; Gallas Torreira, A; Galli, D; Gandelman, M; Gandini, P; Gao, Y; Garnier, J-C; Garofoli, J; Garra Tico, J; Garrido, L; Gascon, D; Gaspar, C; Gauld, R; Gauvin, N; Gersabeck, M; Gershon, T; Ghez, Ph; Gibson, V; Gligorov, V V; Göbel, C; Golubkov, D; Golutvin, A; Gomes, A; Gordon, H; Grabalosa Gándara, M; Graciani Diaz, R; Granado Cardoso, L A; Graugés, E; Graziani, G; Grecu, A; Greening, E; Gregson, S; Gui, B; Gushchin, E; Guz, Yu; Gys, T; Hadjivasiliou, C; Haefeli, G; Haen, C; Haines, S C; Hampson, T; Hansmann-Menzemer, S; Harji, R; Harnew, N; Harrison, J; Harrison, P F; Hartmann, T; He, J; Heijne, V; Hennessy, K; Henrard, P; Hernando Morata, J A; van Herwijnen, E; Hicks, E; Holubyev, K; Hopchev, P; Hulsbergen, W; Hunt, P; Huse, T; Huston, R S; Hutchcroft, D; Hynds, D; Iakovenko, V; Ilten, P; Imong, J; Jacobsson, R; Jaeger, A; Jahjah Hussein, M; Jans, E; Jansen, F; Jaton, P; Jean-Marie, B; Jing, F; John, M; Johnson, D; Jones, C R; Jost, B; Kaballo, M; Kandybei, S; Karacson, M; Karbach, T M; Keaveney, J; Kenyon, I R; Kerzel, U; Ketel, T; Keune, A; Khanji, B; Kim, Y M; Knecht, M; Koopman, R F; Koppenburg, P; Korolev, M; Kozlinskiy, A; Kravchuk, L; Kreplin, K; Kreps, M; Krocker, G; Krokovny, P; Kruse, F; Kruzelecki, K; Kucharczyk, M; Kvaratskheliya, T; La Thi, V N; Lacarrere, D; Lafferty, G; Lai, A; Lambert, D; Lambert, R W; Lanciotti, E; Lanfranchi, G; Langenbruch, C; Latham, T; Lazzeroni, C; Le Gac, R; van Leerdam, J; Lees, J -P; Lefèvre, R; Leflat, A; Lefrançois, J; Leroy, O; Lesiak, T; Li, L; Li Gioi, L; Lieng, M; Liles, M; Lindner, R; Linn, C; Liu, B; Liu, G; von Loeben, J; Lopes, J H; Lopez Asamar, E; Lopez-March, N; Lu, H; Luisier, J; Mac Raighne, A; Machefert, F; Machikhiliyan, I V; Maciuc, F; Maev, O; Magnin, J; Malde, S; Mamunur, R M D; Manca, G; Mancinelli, G; Mangiafave, N; Marconi, U; Märki, R; Marks, J; Martellotti, G; Martens, A; Martin, L; Martín Sánchez, A; Martinez Santos, D; Massafferri, A; Mathe, Z; Matteuzzi, C; Matveev, M; Maurice, E; Maynard, B; Mazurov, A; McGregor, G; McNulty, R; Meissner, M; Merk, M; Merkel, J; Messi, R; Miglioranzi, S; Milanes, D A; Minard, M -N; Molina Rodriguez, J; Monteil, S; Moran, D; Morawski, P; Mountain, R; Mous, I; Muheim, F; Müller, K; Muresan, R; Muryn, B; Muster, B; Musy, M; Mylroie-Smith, J; Naik, P; Nakada, T; Nandakumar, R; Nasteva, I; Nedos, M; Needham, M; Neufeld, N; Nguyen, A D; Nguyen-Mau, C; Nicol, M; Niess, V; Nikitin, N; Nikodem, T; Nomerotski, A; Novoselov, A; Oblakowska-Mucha, A; Obraztsov, V; Oggero, S; Ogilvy, S; Okhrimenko, O; Oldeman, R; Orlandea, M; Otalora Goicochea, J M; Owen, P; Pal, B K; Palacios, J; Palano, A; Palutan, M; Panman, J; Papanestis, A; Pappagallo, M; Parkes, C; Parkinson, C J; Passaleva, G; Patel, G D; Patel, M; Paterson, S K; Patrick, G N; Patrignani, C; Pavel-Nicorescu, C; Pazos Alvarez, A; Pellegrino, A; Penso, G; Pepe Altarelli, M; Perazzini, S; Perego, D L; Perez Trigo, E; Pérez-Calero Yzquierdo, A; Perret, P; Perrin-Terrin, M; Pessina, G; Petrella, A; Petrolini, A; Phan, A; Picatoste Olloqui, E; Pie Valls, B; Pietrzyk, B; Pilař, T; Pinci, D; Plackett, R; Playfer, S; Plo Casasus, M; Polok, G; Poluektov, A; Polycarpo, E; Popov, D; Popovici, B; Potterat, C; Powell, A; Prisciandaro, J; Pugatch, V; Puig Navarro, A; Qian, W; Rademacker, J H; Rakotomiaramanana, B; Rangel, M S; Raniuk, I; Raven, G; Redford, S; Reid, M M; dos Reis, A C; Ricciardi, S; Richards, A; Rinnert, K; Roa Romero, D A; Robbe, P; Rodrigues, E; Rodrigues, F; Rodriguez Perez, P; Rogers, G J; Roiser, S; Romanovsky, V; Rosello, M; Rouvinet, J; Ruf, T; Ruiz, H; Sabatino, G; Saborido Silva, J J; Sagidova, N; Sail, P; Saitta, B; Salzmann, C; Sannino, M; Santacesaria, R; Santamarina Rios, C; Santinelli, R; Santovetti, E; Sapunov, M; Sarti, A; Satriano, C; Satta, A; Savrie, M; Savrina, D; Schaack, P; Schiller, M; Schleich, S; Schlupp, M; Schmelling, M; Schmidt, B; Schneider, O; Schopper, A; Schune, M -H; Schwemmer, R; Sciascia, B; Sciubba, A; Seco, M; Semennikov, A; Senderowska, K; Sepp, I; Serra, N; Serrano, J; Seyfert, P; Shapkin, M; Shapoval, I; Shatalov, P; Shcheglov, Y; Shears, T; Shekhtman, L; Shevchenko, O; Shevchenko, V; Shires, A; Silva Coutinho, R; Skwarnicki, T; Smith, N A; Smith, E; Sobczak, K; Soler, F J P; Solomin, A; Soomro, F; Souza De Paula, B; Spaan, B; Sparkes, A; Spradlin, P; Stagni, F; Stahl, S; Steinkamp, O; Stoica, S; Stone, S; Storaci, B; Straticiuc, M; Straumann, U; Subbiah, V K; Swientek, S; Szczekowski, M; Szczypka, P; Szumlak, T; T'Jampens, S; Teodorescu, E; Teubert, F; Thomas, C; Thomas, E; van Tilburg, J; Tisserand, V; Tobin, M; Tolk, S; Topp-Joergensen, S; Torr, N; Tournefier, E; Tourneur, S; Tran, M T; Tsaregorodtsev, A; Tuning, N; Ubeda Garcia, M; Ukleja, A; Urquijo, P; Uwer, U; Vagnoni, V; Valenti, G; Vazquez Gomez, R; Vazquez Regueiro, P; Vecchi, S; Velthuis, J J; Veltri, M; Viaud, B; Videau, I; Vieira, D; Vilasis-Cardona, X; Visniakov, J; Vollhardt, A; Volyanskyy, D; Voong, D; Vorobyev, A; Voss, H; Wandernoth, S; Wang, J; Ward, D R; Watson, N K; Webber, A D; Websdale, D; Whitehead, M; Wiedner, D; Wiggers, L; Wilkinson, G; Williams, M P; Williams, M; Wilson, F F; Wishahi, J; Witek, M; Witzeling, W; Wotton, S A; Wyllie, K; Xie, Y; Xing, F; Xing, Z; Yang, Z; Young, R; Yushchenko, O; Zangoli, M; Zavertyaev, M; Zhang, F; Zhang, L; Zhang, W C; Zhang, Y; Zhelezov, A; Zhong, L; Zvyagin, A

    2012-01-01

    The ratio of branching fractions of the radiative $B$ decays $B^0\\to K^{*0}\\gamma$ and $B^0_s\\to \\phi\\gamma$ has been measured using $0.37\\,$fb$^{-1}$ of $pp$ collisions at a centre of mass energy of $\\sqrt{s}=7\\,$TeV, collected by the LHCb experiment. The value obtained is \\begin{equation} \\frac{{\\cal B}(B^0\\to K^{*0}\\gamma)}{{\\cal B}(B^0_s\\to \\phi\\gamma)} = 1.12 \\pm 0.08^{+0.06}_{-0.04}\\phantom{.}^{+0.09}_{-0.08},\

  6. Burn-up measurements coupling gamma spectrometry and neutron measurement

    Energy Technology Data Exchange (ETDEWEB)

    Toubon, H.; Pin, P. [AREVA/CANBERRA, 1 rue des Herons, 78182 St Quentin-en-Yvelines Cedex (France); Lebrun, A. [IAEA, Wagramer Strasse 5, PO Box 100, Vienna (Austria); Oriol, L.; Saurel, N. [CEA Cadarache, 13108 Saint Paul Lez Durance Cedex (France); Gain, T. [AREVA/COGEMA Reprocessing Business Unit, La Hague, 50444 Beaumont Hague Cedex (France)

    2006-07-01

    The need to apply for burn-up credit arises with the increase of the initial enrichment of nuclear fuel. When burn-up credit is used in criticality safety studies, it is often necessary to confirm it by measurement. For the last 10 years, CANBERRA has manufactured the PYTHON system for such measurements. However, the method used in the PYTHON itself uses certain reactor data to arrive at burn-up estimates. Based on R and D led by CEA and COGEMA in the framework of burn-up measurement for burn-up credit and safeguards applications, CANBERRA is developing the next generation of burn-up measurement device. This new product, named SMOPY, is able to measure burn-up of any kind of irradiated fuel assembly with a combination of gamma spectrometry and passive neutron measurements. The measurement data is used as input to the CESAR depletion code, which has been developed and qualified by CEA and COGEMA for burn-up credit determinations. In this paper, we explain the complementary nature of the gamma and neutron measurements. In addition, we draw on our previous experience from PYTHON system and from COGEMA La Hague to show what types of evaluations are required to qualify the SMOPY system, to estimate its uncertainties, and to detect discrepancies in the fuel data given by the reactor plant to characterize the irradiated fuel assembly. (authors)

  7. Burn-up measurements coupling gamma spectrometry and neutron measurement

    International Nuclear Information System (INIS)

    Toubon, H.; Pin, P.; Lebrun, A.; Oriol, L.; Saurel, N.; Gain, T.

    2006-01-01

    The need to apply for burn-up credit arises with the increase of the initial enrichment of nuclear fuel. When burn-up credit is used in criticality safety studies, it is often necessary to confirm it by measurement. For the last 10 years, CANBERRA has manufactured the PYTHON system for such measurements. However, the method used in the PYTHON itself uses certain reactor data to arrive at burn-up estimates. Based on R and D led by CEA and COGEMA in the framework of burn-up measurement for burn-up credit and safeguards applications, CANBERRA is developing the next generation of burn-up measurement device. This new product, named SMOPY, is able to measure burn-up of any kind of irradiated fuel assembly with a combination of gamma spectrometry and passive neutron measurements. The measurement data is used as input to the CESAR depletion code, which has been developed and qualified by CEA and COGEMA for burn-up credit determinations. In this paper, we explain the complementary nature of the gamma and neutron measurements. In addition, we draw on our previous experience from PYTHON system and from COGEMA La Hague to show what types of evaluations are required to qualify the SMOPY system, to estimate its uncertainties, and to detect discrepancies in the fuel data given by the reactor plant to characterize the irradiated fuel assembly. (authors)

  8. The selection of radiation tolerant electrical/electronic components for gamma radiation environments in the nuclear power industry

    International Nuclear Information System (INIS)

    Garlick, D.R.

    1984-09-01

    This report briefly describes the mechanisms, units and effects of 1 MeV range gamma radiation on electrical/electronic components and materials. Information is tabulated on the gamma radiation tolerance of a wide range of components and materials. A radiation testing service, based at Harwell, is described. Lists of interested manufacturers and organisations are given. (author)

  9. Gamma-ray measurements with the segmented gamma scan

    International Nuclear Information System (INIS)

    Martin, E.R.; Jones, D.F.; Parker, J.L.

    1977-12-01

    A revised and updated operation and maintenance manual for the segmented gamma-scan instrument is presented, which describes routine assay techniques as well as the theory of operation in sufficient depth that an experienced assayist can make nonroutine assays on a wide variety of materials and samples. In addition, complete electronic and electrical schematics of the Los Alamos Scientific Laboratory (LASL)-designed portions of the system are presented, along with sufficient system and circuit description to facilitate maintenance and troubleshooting. Complete software system descriptions are included, although detailed listings would have to be obained from LASL in order to make machine-language code changes

  10. Measurements of the gamma-quanta angular distributions emitted from neutron inelastic scattering on 28Si

    Science.gov (United States)

    Fedorov, N. A.; Grozdanov, D. N.; Bystritskiy, V. M.; Kopach, Yu. N.; Ruskov, I. N.; Skoy, V. R.; Tretyakova, T. Yu.; Zamyatin, N. I.; Wang, D.; Aliev, F. A.; Hramco, C.; Gandhi, A.; Kumar, A.; Dabylova, S.; Bogolubov, E. P.; Barmakov, Yu. N.

    2018-04-01

    The characteristic gamma radiation from the interaction of 14.1 MeV neutrons with a natural silicon sample is investigated with Tagged Neutron Method (TNM). The anisotropy of gamma-ray emission of 1.779 MeV was measured at 11 azimuth angles with a step of ∠15°. The present results are in good agreement with some recent experimental data.

  11. Terrestrial gamma ray radiation in Cornwall

    International Nuclear Information System (INIS)

    Grainger, C.R.

    1986-01-01

    A report is given of an airborne survey of Cornwall using a scintillation counter to measure the natural radioactivity. This showed 271 sources of abnormal (much higher than national mean) levels of radioactivity. The effects of these on the population are discussed. (U.K.)

  12. Efficiency and attenuation correction factors determination in gamma spectrometric assay of bulk samples using self radiation

    International Nuclear Information System (INIS)

    Haddad, Kh.

    2009-02-01

    Gamma spectrometry forms the most important and capable tool for measuring radioactive materials. Determination of the efficiency and attenuation correction factors is the most tedious problem in the gamma spectrometric assay of bulk samples. A new experimental and easy method for these correction factors determination using self radiation was proposed in this work. An experimental study of the correlation between self attenuation correction factor and sample thickness and its practical application was also introduced. The work was performed on NORM and uranyl nitrate bulk sample. The results of proposed methods agreed with those of traditional ones.(author)

  13. Natural gamma-ray spectrometry as a tool for radiation dose and radon hazard modelling

    International Nuclear Information System (INIS)

    Verdoya, M.; Chiozzi, P.; De Felice, P.; Pasquale, V.; Bochiolo, M.; Genovesi, I.

    2009-01-01

    We reviewed the calibration procedures of gamma-ray spectrometry with particular emphasis to factors that affect accuracy, detection limits and background radiation in field measurements for dosimetric and radon potential mapping. Gamma-ray spectra were acquired in western Liguria (Italy). The energy windows investigated are centred on the photopeaks of 214 Bi (1.76 MeV), 208 Tl (2.62 MeV) and 40 K (1.46 MeV). The inferred absorbed dose rate and the radon flux are estimated to be lower than 60 nGy h -1 and 22 Bq m -2 h -1 , respectively.

  14. Gamma radiation compton scattering effect from the Ukrytie Object on the radiation situation at the Chernobyl' NPP territory

    International Nuclear Information System (INIS)

    Alekseeva, E.A.; Volkovich, A.G.; Koba, G.I.; Liksonov, V.I.; Stepanov, V.E.; Tyurin, A.S.; Urutskoev, L.I.; Chesnokov, A.V.

    1989-01-01

    With the aim of determination of the angular distribution of the gamma-radiation (GR) exposure dose rate (EDR) around the Ukrytie Object (UO) are described the measurement results of GR EDR in July 1988 at the territory, adjoining to UO. The conclusion is made that the main contribution into EDR ensures GR, scattered as a result of the Compton effect on air molecules and that the contribution of the NPP territory is small. 10 figs.; 3 tabs

  15. Method for the diffraction of terrestrial radiation, GAMMA radiation, etc

    International Nuclear Information System (INIS)

    Busenbach, P.

    1975-01-01

    The patent claim concerns shielding against so-called earth radiation. These rays originate from water veins etc., cannot be defined any closer, and are supposed to cause injury to health. The author claims that shielding is possible with the aid of welding electrodes which have cores of nickel. (ORU/LN) [de

  16. External gamma radiation survey for oil wellheads in Saudi Arabia

    International Nuclear Information System (INIS)

    Nassar, Rafat M.; Mously, Khalid A.; Cowie, Michael I.

    2008-01-01

    Naturally occurring radioactive material (NORM) is known to be associated with oil and gas extraction. As part of a comprehensive NORM management strategy, Saudi Aramco needed to determine the extent of NORM contamination associated with their oil and gas operations. As part of that strategy, this study focused on external gamma survey of oil producing wellheads at various locations. The study aimed to: 1-) Identify wellheads with elevated gamma radiation dose rate; 2-) Specify the exact locations of the high dose rates on the wellheads; 3-) Identify the radioisotopes responsible for the high dose rates; and 4-) Propose worker protection requirements during maintenance. The majority (∼92%) of the surveyed wellheads showed no enhanced gamma dose-rate above background level. From the remaining ∼8%, only a few wellheads showed dose rates between 1,000-3,700 n Sv/h. The study revealed that NORM contamination tends to accumulate at turns of the pipes, around pipe diameter changes, the joints, the back of valves, and at the base of the wellhead. Also, for a given location, NORM build up on the interior of pipework varies over time and continues to migrate down stream until it reaches the Gas and Oil Separation Plants (GOSP). There NORM is expected to accumulate and reside in the form of sludge. Gamma spectroscopy analysis revealed that 226 Ra and its progeny are responsible for the high radiation dose rates detected. It was concluded that NORM will not pose significant radiation hazards to workers as long as the tubing and piping are not opened. (author)

  17. Standardization of test conditions for gamma camera performance measurement

    International Nuclear Information System (INIS)

    Jordan, K.

    1980-01-01

    The actual way of measuring gamma camera performance is to use point sources or flood sources in air, often in combination with bar phantoms. This method mostly brings best performance parameters for cameras but it has nothing in common with the use of a camera in clinical practice. Particular in the case of low energy emitters, like Tc-99m, the influence of scattered radiation over the performance of cameras is very high. Therefore it is important to have test conditions of radionuclide imaging devices, that will approach as best as practicable the measuring conditions in clinical applications. It is therefore a good news that the International Electrochemical Commission IEC has prepared a draft 'Characteristics and test conditions of radionuclide imaging devices' which is now submitted to the national committees for formal approval under the Six Months' Rule. Some essential points of this document are discussed in the paper. (orig.) [de

  18. The influence of geology on terrestrial gamma radiation dose rate in Pahang state, Malaysia

    International Nuclear Information System (INIS)

    Gabdo, H.T.; Ramli, A.T.; Sanusi, M.S.; Garba, N.N.; Saleh, M.A.

    2015-01-01

    Terrestrial gamma radiation dose (TGRD) rate measurements have been made in Pahang state, Malaysia. Significant variations were found between TGRD measurements and the underlying geological formations. In some cases revealing significant elevations of TGRD. The acid-intrusive geological formation has the highest mean TGRD measurement of 367 nGy/h -1 . This is more than six times the world average value of 59 nGy/h -1 , while the quaternary geological formation has the lowest mean gamma radiation dose rate of 99 nGy h -1 . The annual effective dose equivalent outdoor to the population was 0.216 mSv. The lifetime equivalent dose and relative lifetime cancer risks for an individual living in Pahang state were 81 mSv and 4.7 x 10 -3 respectively. These values are more than two times the world average of 34 mSv and 1.95 x 10 -3 respectively. (author)

  19. Radon flux maps for the Netherlands and Europe using terrestrial gamma radiation derived from soil radionuclides

    Science.gov (United States)

    Manohar, S. N.; Meijer, H. A. J.; Herber, M. A.

    2013-12-01

    Naturally occurring radioactive noble gas, radon (222Rn) is a valuable tracer to study atmospheric processes and to validate global chemical transport models. However, the use of radon as a proxy in atmospheric and climate research is limited by the uncertainties in the magnitude and distribution of the radon flux density over the Earth's surface. Terrestrial gamma radiation is a useful proxy for generating radon flux maps. A previously reported radon flux map of Europe used terrestrial gamma radiation extracted from automated radiation monitoring networks. This approach failed to account for the influence of local artificial radiation sources around the detector, leading to under/over estimation of the reported radon flux values at different locations. We present an alternative approach based on soil radionuclides which enables us to generate accurate radon flux maps with good confidence. Firstly, we present a detailed comparison between the terrestrial gamma radiation obtained from the National Radiation Monitoring network of the Netherlands and the terrestrial gamma radiation calculated from soil radionuclides. Extending further, we generated radon flux maps of the Netherlands and Europe using our proposed approach. The modelled flux values for the Netherlands agree reasonably well with the two observed direct radon flux measurements (within 2σ level). On the European scale, we find that the observed radon flux values are higher than our modelled values and we introduce a correction factor to account for this difference. Our approach discussed in this paper enables us to develop reliable and accurate radon flux maps in countries with little or no information on radon flux values.

  20. Prompt gamma radiation activation analysis (PGNAA)

    International Nuclear Information System (INIS)

    Ovalle, M; Navarro, G; Henriquez, O; Andonie, A; Pereda, C

    2003-01-01

    This Nuclear technique (PGNAA) uses thermal neutron beams produced on nuclear reactor. The RECH-1 reactor, has this facility since several years. In this work we show the development of a set of measurements made with the final propose to obtain a set of future standards to be used on solid samples quantification. It is also described the most used quantification methods based on this technique. It is also wanted to remark that this technique allows to show the natural elements isotopic composition. As an example we show a natural Ni study (Au)

  1. Gamma radiation treatment activates glucomoringin synthesis in Moringa oleifera

    Directory of Open Access Journals (Sweden)

    Tsifhiwa Ramabulana

    Full Text Available Abstract Plants are a very rich source of pharmacologically relevant metabolites. However, the relative concentrations of these compounds are subject to the genetic make-up, the physiological state of the plant as well as environmental effects. Recently, metabolic perturbations through the use of abiotic stressors have proven to be a valuable strategy for increasing the levels of these compounds. Oxidative stress-associated stressors, including ionizing radiation, have also been reported to induce metabolites with various biological activities in plants. Hence, the aim of the current study was to investigate the effect of gamma radiation on the induction of purported anti-cancerous metabolites, glucomoringin and its derivatives, in Moringa oleifera Lam., Moringaceae. Here, an UHPLC-qTOF-MS-based targeted metabolic fingerprinting approach was used to evaluate the effect of gamma radiation treatment on the afore-mentioned health-beneficial secondary metabolites of M. oleifera. Following radiation, an increase in glucomoringin and three acylated derivatives was noted. As such, these molecules can be regarded as components of the inducible defense mechanism of M. oleifera as opposed to being constitutive components as it has previously been assumed. This might be an indication of a possible, yet unexplored role of moringin against the effects of oxidative stress in M. oleifera plants. The results also suggest that plants undergoing photo-oxidative stress could accumulate higher amounts of glucomoringin and related molecules.

  2. The effects of gamma radiation on soybean isoflavones contents

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Marcos R.R. de; Mastro, Nelida L. del [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)], e-mail: nlmastro@ipen.br, e-mail: mrramos@ipen.br; Mandarino, Jose M.G. [EMBRAPA Soybean, Londrina, PR (Brazil)], e-mail: jmarcos@cnpso.embrapa.br

    2009-07-01

    Soybean (Glycine max) is the most common source of isoflavones in human feeding. It was suggested that there is a correlation among antioxidant activity of flavonoids and total phenolics content. Plants use isoflavones and their derivatives as part of the plant's defensive arsenal, to ward off disease-causing pathogenic fungi and other microbes. Highly processed foods made from legumes, such as tofu, retain most of their isoflavone content, with the exception of fermented miso, which has increased levels. Little is known about the influence of oxidative stress induced by radiation on the isoflavones contents. In the present paper, the effects of gamma irradiation on soybean isoflavones contents are presented. Samples from several Brazilian soybean cultivars were gamma irradiated with doses of 0, 1, 2, 5 e 10 kGy, dose rate about 3 kGy/h in a {sup 60}Co (Gammacell 220 - AECL). Isoflavones contents were determined after extraction with 70% ethanol containing 0.1% acetic acid by an HPLC method. The total isoflavone content remained almost unchanged with the increase of radiation dose up to 10 kGy. Although a general correlation among total isoflavone content and radiation dose was not found, some data suggest that for a few of the isoflavones from specific cultivars, the increase in the radiation dose induced a decrease in their content as for glucosyl glucosides and malonyl isoflavones, as well as an increase in their aglycone content. (author)

  3. The effects of gamma radiation on soybean isoflavones contents

    International Nuclear Information System (INIS)

    Oliveira, Marcos R.R. de; Mastro, Nelida L. del; Mandarino, Jose M.G.

    2009-01-01

    Soybean (Glycine max) is the most common source of isoflavones in human feeding. It was suggested that there is a correlation among antioxidant activity of flavonoids and total phenolics content. Plants use isoflavones and their derivatives as part of the plant's defensive arsenal, to ward off disease-causing pathogenic fungi and other microbes. Highly processed foods made from legumes, such as tofu, retain most of their isoflavone content, with the exception of fermented miso, which has increased levels. Little is known about the influence of oxidative stress induced by radiation on the isoflavones contents. In the present paper, the effects of gamma irradiation on soybean isoflavones contents are presented. Samples from several Brazilian soybean cultivars were gamma irradiated with doses of 0, 1, 2, 5 e 10 kGy, dose rate about 3 kGy/h in a 60 Co (Gammacell 220 - AECL). Isoflavones contents were determined after extraction with 70% ethanol containing 0.1% acetic acid by an HPLC method. The total isoflavone content remained almost unchanged with the increase of radiation dose up to 10 kGy. Although a general correlation among total isoflavone content and radiation dose was not found, some data suggest that for a few of the isoflavones from specific cultivars, the increase in the radiation dose induced a decrease in their content as for glucosyl glucosides and malonyl isoflavones, as well as an increase in their aglycone content. (author)

  4. Gamma radiation and the conservation of natural orange juice

    International Nuclear Information System (INIS)

    Iemma, Juliana; Alcarde, Andre Ricardo; Domarco, Rachel Elisabeth; Spoto, Marta Helena Fillet; Blumer, Lucimara; Matraia, Clarice

    1999-01-01

    The effect of gamma radiation was evaluated on the microbiological population, soluble solids content, acidity, p H and ascorbic acid content of natural orange juice. Microbial activity may cause deterioration of orange juice. Irradiation is a process of food conservation which eliminates microorganisms. nevertheless radiation may affect some characteristics of irradiated food. The experimental design was a 4 x 5 factorial scheme, including control and 3 rates of irradiation (2.0, 4.0 and 6.0 kGy) and 5 storage periods (1, 7, 14, 21 and 28 days), with 2 replicates. Samples of juice were extracted from variety Pera oranges and irradiated at a rate of 2.0 kGy/h ( 60 Cobalt) and thereafter stored at 5 +- 3 deg C. Results showed small changes in soluble solids content, acidity and p H, for all treatments. The ratio soluble solids/acidity was also determined and showed little variation for all treatments. There was a reduction on ascorbic acid content of the orange juice with increased radiation dosage and storage time. Gamma radiation was effective in reducing the microbiological population of the juice. (author)

  5. Real time monitoring automation of dose rate absorbed in air due to environmental gamma radiation

    International Nuclear Information System (INIS)

    Dominguez Ley, Orlando; Capote Ferrera, Eduardo; Carrazana Gonzalez, Jorge A.; Manzano de Armas, Jose F.; Alonso Abad, Dolores; Prendes Alonso, Miguel; Tomas Zerquera, Juan; Caveda Ramos, Celia A.; Kalber, Olof; Fabelo Bonet, Orlando; Montalvan Estrada, Adelmo; Cartas Aguila, Hector; Leyva Fernandez, Julio C.

    2005-01-01

    The Center of Radiation Protection and Hygiene (CPHR) as the head institution of the National Radiological Environmental Surveillance Network (RNVRA) has strengthened its detection and response capacity for a radiological emergency situation. The measurements of gamma dose rate at the main point of the RNVRA are obtained in real time and the CPHR receives the data coming from those points in a short time. To achieve the operability of the RNVRA it was necessary to complete the existent monitoring facilities using 4 automatic gamma probes, implementing in this way a real time measurement system. The software, GenitronProbe for obtaining the data automatically from the probe, Data Mail , for sending the data via e-mail, and Gamma Red , for receiving and processing the data in the head institution ,were developed

  6. IVVS actuating system compatibility test to ITER gamma radiation conditions

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, Paolo, E-mail: paolo.rossi@enea.it [Associazione EURATOM-ENEA sulla Fusione, 45 Via Enrico Fermi, 00044 Frascati, Rome (Italy); Collibus, M. Ferri de; Florean, M.; Monti, C.; Mugnaini, G.; Neri, C.; Pillon, M.; Pollastrone, F. [Associazione EURATOM-ENEA sulla Fusione, 45 Via Enrico Fermi, 00044 Frascati, Rome (Italy); Baccaro, S.; Piegari, A. [ENEA CR Casaccia, 301 Via Anguillarese, 00123 Santa Maria di Galeria, Rome (Italy); Damiani, C.; Dubus, G. [Fusion For Energy c/Josep Pla, n° 2 Torres Diagonal Litoral, 08019 Barcelona (Spain)

    2013-10-15

    Highlights: • ENEA developed and tested a prototype of a laser In Vessel Viewing and ranging System (IVVS) for ITER. • One piezo-motor prototype has been tested on the ENEA Calliope gamma irradiation facility to verify its compatibility to ITER gamma radiation conditions. • After a total dose of more than 4 MGy the piezo-motor maintained almost the same working parameters monitored before test without any evident and significant degradation of functionality. • After the full gamma irradiation test, the same piezo-motor assembly will be tested with 14 MeV neutrons irradiation using ENEA FNG facility. -- Abstract: The In Vessel Viewing System (IVVS) is a fundamental remote handling equipment, which will be used to make a survey of the status of the blanket first wall and divertor plasma facing components. A design and testing activity is ongoing, in the framework of a Fusion for Energy (F4E) grant agreement, to make the IVVS probe design compatible with ITER operating conditions and in particular, but not only, with attention to neutrons and gammas fluxes and both space constraints and interfaces. The paper describes the testing activity performed on the customized piezoelectric motors and the main components of the actuating system of the IVVS probe with reference to ITER gamma radiation conditions. In particular the test is performed on the piezoelectric motor, optical encoder and small scale optical samples .The test is carried out on the ENEA Calliope gamma irradiation facility at ITER relevant gamma fields at rate of about 2.5 kGy/h and doses of 4 MGy. The paper reports in detail the setup arrangement of the test campaign in order to verify significant working capability of the IVVS actuating components and the results are shown in terms of functional performances and parameters. The overall test campaign on IVVS actuating system will be completed on other ENEA testing facilities in order to verify compatibility to Magnetic field, neutrons and thermal

  7. IVVS actuating system compatibility test to ITER gamma radiation conditions

    International Nuclear Information System (INIS)

    Rossi, Paolo; Collibus, M. Ferri de; Florean, M.; Monti, C.; Mugnaini, G.; Neri, C.; Pillon, M.; Pollastrone, F.; Baccaro, S.; Piegari, A.; Damiani, C.; Dubus, G.

    2013-01-01

    Highlights: • ENEA developed and tested a prototype of a laser In Vessel Viewing and ranging System (IVVS) for ITER. • One piezo-motor prototype has been tested on the ENEA Calliope gamma irradiation facility to verify its compatibility to ITER gamma radiation conditions. • After a total dose of more than 4 MGy the piezo-motor maintained almost the same working parameters monitored before test without any evident and significant degradation of functionality. • After the full gamma irradiation test, the same piezo-motor assembly will be tested with 14 MeV neutrons irradiation using ENEA FNG facility. -- Abstract: The In Vessel Viewing System (IVVS) is a fundamental remote handling equipment, which will be used to make a survey of the status of the blanket first wall and divertor plasma facing components. A design and testing activity is ongoing, in the framework of a Fusion for Energy (F4E) grant agreement, to make the IVVS probe design compatible with ITER operating conditions and in particular, but not only, with attention to neutrons and gammas fluxes and both space constraints and interfaces. The paper describes the testing activity performed on the customized piezoelectric motors and the main components of the actuating system of the IVVS probe with reference to ITER gamma radiation conditions. In particular the test is performed on the piezoelectric motor, optical encoder and small scale optical samples .The test is carried out on the ENEA Calliope gamma irradiation facility at ITER relevant gamma fields at rate of about 2.5 kGy/h and doses of 4 MGy. The paper reports in detail the setup arrangement of the test campaign in order to verify significant working capability of the IVVS actuating components and the results are shown in terms of functional performances and parameters. The overall test campaign on IVVS actuating system will be completed on other ENEA testing facilities in order to verify compatibility to Magnetic field, neutrons and thermal

  8. Nuclear radiation-warning detector that measures impedance

    Science.gov (United States)

    Savignac, Noel Felix; Gomez, Leo S; Yelton, William Graham; Robinson, Alex; Limmer, Steven

    2013-06-04

    This invention is a nuclear radiation-warning detector that measures impedance of silver-silver halide on an interdigitated electrode to detect light or radiation comprised of alpha particles, beta particles, gamma rays, X rays, and/or neutrons. The detector is comprised of an interdigitated electrode covered by a layer of silver halide. After exposure to alpha particles, beta particles, X rays, gamma rays, neutron radiation, or light, the silver halide is reduced to silver in the presence of a reducing solution. The change from the high electrical resistance (impedance) of silver halide to the low resistance of silver provides the radiation warning that detected radiation levels exceed a predetermined radiation dose threshold.

  9. Effect of gamma radiation on electrical and optical properties of (TeO2)

    Indian Academy of Sciences (India)

    Employing dose dependence of the current, some real-time gamma radiation dosimeters have been prepared, which ... are on world over to investigate the influence of gamma radi- ... Employing thermal evaporation in a vacuum, thin films of.

  10. Gamma radiation induced changes in nuclear waste glass containing Eu

    Science.gov (United States)

    Mohapatra, M.; Kadam, R. M.; Mishra, R. K.; Kaushik, C. P.; Tomar, B. S.; Godbole, S. V.

    2011-10-01

    Gamma radiation induced changes were investigated in sodium-barium borosilicate glasses containing Eu. The glass composition was similar to that of nuclear waste glasses used for vitrifying Trombay research reactor nuclear waste at Bhabha Atomic Research Centre, India. Photoluminescence (PL) and electron paramagnetic resonance (EPR) techniques were used to study the speciation of the rare earth (RE) ion in the matrix before and after gamma irradiation. Judd-Ofelt ( J- O) analyses of the emission spectra were done before and after irradiation. The spin counting technique was employed to quantify the number of defect centres formed in the glass at the highest gamma dose studied. PL data suggested the stabilisation of the trivalent RE ion in the borosilicate glass matrix both before and after irradiation. It was also observed that, the RE ion distributes itself in two different environments in the irradiated glass. From the EPR data it was observed that, boron oxygen hole centre based radicals are the predominant defect centres produced in the glass after irradiation along with small amount of E’ centres. From the spin counting studies the concentration of defect centres in the glass was calculated to be 350 ppm at 900 kGy. This indicated the fact that bulk of the glass remained unaffected after gamma irradiation up to 900 kGy.

  11. Radiation safety of gamma and electron irradiation facilities

    International Nuclear Information System (INIS)

    1992-01-01

    There are currently some 160 gamma irradiation facilities and over 600 electron beam facilities in operation throughout virtually all Member States of the IAEA. The most widespread uses of these facilities are for the sterilization of medical and pharmaceutical products, the preservation of foodstuffs, polymer synthesis and modification, and the eradication of insect infestation. The safety record of this industry has been very good. Nevertheless, there is a potential for accidents with serious consequences. Gamma and electron beam facilities produce very high dose rates during irradiation, so that a person accidentally present in the irradiation chamber can receive a lethal dose within minutes or seconds. Precautions against uncontrolled entry must therefore be taken. Furthermore, gamma irradiation facilities contain large amounts of radioactivity and if the mechanism for retracting the source is damaged, the source may remain exposed, inhibiting direct access to carry out remedial work. Contamination can result from corroded or damaged sources, and decontamination can be very expensive. These aspects clearly indicate the need to achieve a high degree of safety and reliability in the facilities. This can be accomplished by effective quality control together with careful design, manufacture, installation, operation and decommissioning. The guidance in this Safety Series publication is intended for competent authorities responsible for regulating the use of radiation sources as well as the manufacturers, suppliers, installers and users of gamma and electron beam facilities. 20 refs, 6 figs

  12. Responses of a grassland arthropod community to chronic beta and gamma radiation

    International Nuclear Information System (INIS)

    Styron, C.E.; Dodson, G.J.; Beauchamp, J.J.; Miller, F.L. Jr.

    1976-01-01

    A long-term project was initiated in 1968 at Oak Ridge National Laboratory to assess effects of mixed beta and gamma radiation from simulated fallout on a grassland ecosystem. Beta and gamma radiation dose rates in microhabitats of the experimentally contaminated enclosure were measured with LiF thermoluminescent microdosimeters. Extensive statistical analyses of data on numbers of individuals collected for each of 76 arthropod and 2 molluscan taxa have identified no lasting significant changes in similarity or species diversity of experimental versus control communities as the result of the long-term irradiation at low dose rates. Natural fluctuations in community dynamics obscured any possible radiation effects. Thus, the apparent threshold for mixed beta and gamma radiation inducing changes in community structure must be above the exposure rate range of 2.3 to 13 rad/day delivered during the 5 yr of observation. Establishing such a threshold is of importance in assessing the impact of communities subjected to chronic, low level environmental exposure to ionizing radiation

  13. Gamma radiation, an aid to geologic mapping on the Arabian shield, Kingdom of Saudi Arabia

    International Nuclear Information System (INIS)

    Flanigan, V.J.

    1972-01-01

    Aerial gamma-radiation measurements in the Jabal Al Qarah quadrangle, Saudi Arabia, correlate with and complement magnetic data in distinguishing common Precambrian rock types. Areas of lower total-count gamma radiation correlate with areas of more intense magnetic patterns, which in turn correlate with areas of mafic rocks, as suggested from the study of the geophysical and geologic data of the Jabal Ishmas and Jabal Yafikh quadrangles adjacent to the north. In contrast, areas that reflect a lower magnetic intensity tend to show considerable variation in the radiation intensity and can be interpreted as being underlain by granitic rocks. On the basis of extrapolation of geophysical-geologic relationships established previously, selected radiation levels may be used to identify mappable rock units. Thus, radioactivity levels of 2,000 to 4,000 cpM suggest mafic rocks, levels of 4,000 to 6,000 cpM represent metavolcanic and metasedimentary rocks, levels of 7,000 to 10,000 cpM are representative of granodiorite gneiss, and levels of more than 11,000 cpM typify granitic rocks. The spectral gamma-radiation data are used to evaluate total-count anomalies and indicators of geologic processes of enrichment, and estimating the amount of isotopes of U, Th, and K within each of the lithologic units. (U.S.)

  14. Towards a new thickness-independent gamma radiation plastic film dosimeter

    International Nuclear Information System (INIS)

    Vieira, Marli Barbosa; Araujo, Patricia L.; Araujo, Elma S.

    2013-01-01

    A 100% national single-use gamma radiation plastic film dosimeter is presented in this work. A new approach for the development of this material allowed a step forward in the performance of poly (methyl metacrylate) films (PMMA) colored with bromothymol blue (BTB) acid-base indicator. We manage to improve dosimeter performance by introducing a gamma radiation insensitive dye to compensate film thickness variations. By doing so, we were able to obtain consistent dose-response correlations within a set of samples presenting 46 to 110 micrometers in thickness. Hence, our PMMA/BTB-P film dosimeter is suitable to measure absorbed dose in the 2-100kGy range even when film thickness undergoes more than 100% of variation. In addition, dose response data remain practically unaltered for four months after the exposure, when dosimeter films are kept in dark conditions and under refrigeration. The radiation effects on the optical properties were evaluated for Ultraviolet-Visible (UV-Vis) spectrophotometric analysis. Data of characteristic dose-response correlation in terms of changes in the maximum UV-Vis absorption due to radiation, and stability in time are also described. This potential new product is a promising tool for industrial radiation facilities, especially in gamma sterilization of medical supplies. (author)

  15. Gamma-ray lines from radiative dark matter decay

    International Nuclear Information System (INIS)

    Garny, Mathias; Ibarra, Alejandro; Tran, David; Weniger, Christoph

    2011-01-01

    The decay of dark matter particles which are coupled predominantly to charged leptons has been proposed as a possible origin of excess high-energy positrons and electrons observed by cosmic-ray telescopes PAMELA and Fermi LAT. Even though the dark matter itself is electrically neutral, the tree-level decay of dark matter into charged lepton pairs will generically induce radiative two-body decays of dark matter at the quantum level. Using an effective theory of leptophilic dark matter decay, we calculate the rates of radiative two-body decays for scalar and fermionic dark matter particles. Due to the absence of astrophysical sources of monochromatic gamma rays, the observation of a line in the diffuse gamma-ray spectrum would constitute a strong indication of a particle physics origin of these photons. We estimate the intensity of the gamma-ray line that may be present in the energy range of a few TeV if the dark matter decay interpretation of the leptonic cosmic-ray anomalies is correct and comment on observational prospects of present and future Imaging Cherenkov Telescopes, in particular the CTA

  16. Biological wound dressings sterilized with gamma radiation: Mexican clinical experience

    Energy Technology Data Exchange (ETDEWEB)

    Martinez-Pardo, M.E. [Instituto Nacional de Investigaciones Nucleares, Apdo. postal 18-1027, Col. Escandon 11801 Mexico DF (Mexico)], E-mail: memp@nuclear.inin.mx; Ley-Chavez, E. [ISSEMYM Toluca, Mexico DF (Mexico); Reyes-Frias, M.L. [Instituto Nacional de Investigaciones Nucleares, Apdo. postal 18-1027, Col. Escandon 11801 Mexico DF (Mexico); Rodriguez-Ferreyra, P. [Hospital ' Dr. Nicolas San Juan' , Toluca, Mexico DF (Mexico); Vazquez-Maya, L.; Salazar, M.A. [Hospital General de Mexico, Mexico DF (Mexico)

    2007-11-15

    Biological wound dressings sterilized with gamma radiation, such as amnion and pig skin, are a reality in Mexico. These tissues are currently processed in the tissue bank and sterilized in the Gamma Industrial Irradiation Plant; both facilities belong to the Instituto Nacional de Investigaciones Nucleares (ININ) (National Institute of Nuclear Research). With the strong support of the International Atomic Energy Agency, the bank was established at the ININ and the Mexican Ministry of Health issued its sanitary license on July 7, 1999. The Quality Management System of the bank was certified by ISO 9001:2000 on August 1, 2003; the scope of the system is 'Research, Development and Processing of Biological Tissues Sterilized with Gamma Radiation'. At present, more than 150 patients from 16 hospitals have been successfully treated with these tissues. This paper presents a brief description of the tissue processing, as well as the present Mexican clinical experience with children and adult patients who underwent medical treatment with radiosterilized amnion and pig skin, used as biological wound dressings on burns and ocular surface disorders.

  17. Biological wound dressings sterilized with gamma radiation: Mexican clinical experience

    Science.gov (United States)

    Martínez-Pardo, M. E.; Ley-Chávez, E.; Reyes-Frías, M. L.; Rodríguez-Ferreyra, P.; Vázquez-Maya, L.; Salazar, M. A.

    2007-11-01

    Biological wound dressings sterilized with gamma radiation, such as amnion and pig skin, are a reality in Mexico. These tissues are currently processed in the tissue bank and sterilized in the Gamma Industrial Irradiation Plant; both facilities belong to the Instituto Nacional de Investigaciones Nucleares (ININ) (National Institute of Nuclear Research). With the strong support of the International Atomic Energy Agency, the bank was established at the ININ and the Mexican Ministry of Health issued its sanitary license on July 7, 1999. The Quality Management System of the bank was certified by ISO 9001:2000 on August 1, 2003; the scope of the system is "Research, Development and Processing of Biological Tissues Sterilized with Gamma Radiation". At present, more than 150 patients from 16 hospitals have been successfully treated with these tissues. This paper presents a brief description of the tissue processing, as well as the present Mexican clinical experience with children and adult patients who underwent medical treatment with radiosterilized amnion and pig skin, used as biological wound dressings on burns and ocular surface disorders.

  18. Biological wound dressings sterilized with gamma radiation: Mexican clinical experience

    International Nuclear Information System (INIS)

    Martinez-Pardo, M.E.; Ley-Chavez, E.; Reyes-Frias, M.L.; Rodriguez-Ferreyra, P.; Vazquez-Maya, L.; Salazar, M.A.

    2007-01-01

    Biological wound dressings sterilized with gamma radiation, such as amnion and pig skin, are a reality in Mexico. These tissues are currently processed in the tissue bank and sterilized in the Gamma Industrial Irradiation Plant; both facilities belong to the Instituto Nacional de Investigaciones Nucleares (ININ) (National Institute of Nuclear Research). With the strong support of the International Atomic Energy Agency, the bank was established at the ININ and the Mexican Ministry of Health issued its sanitary license on July 7, 1999. The Quality Management System of the bank was certified by ISO 9001:2000 on August 1, 2003; the scope of the system is 'Research, Development and Processing of Biological Tissues Sterilized with Gamma Radiation'. At present, more than 150 patients from 16 hospitals have been successfully treated with these tissues. This paper presents a brief description of the tissue processing, as well as the present Mexican clinical experience with children and adult patients who underwent medical treatment with radiosterilized amnion and pig skin, used as biological wound dressings on burns and ocular surface disorders

  19. Use of natural gamma radiation in the coal mining industry

    International Nuclear Information System (INIS)

    Wykes, J.S.; Adsley, I.; Cooper, L.R.

    1982-01-01

    The technique of delineating coal seams by the use of natural gamma borehole logging sondes has been known for many years. The principle of the technique is that the gamma fluxes in shales are higher than in coals as the abundance of naturally occurring radionuclides is some twenty times greater in the former. This paper discusses other applications where the differeing natural gamma properties of coals and shales can be used. These are: (a) To distinguish between stone (shale) and run-of-mine coal on conveyor belts. A common situation underground is one in which stone from development headings and normal run-of-mine coal have to be batched along the same conveyor system. A natural gamma device capable of distinguishing between such batches of material, and thus allowing suitable mechanical separation, will be described. (b) To provide an accurate measurement of roof coal thickness by measuring the natural gamma flux penetrating the roof coal. To illustrate this examples will be given where this technique is used to provide automatic controlled steering of Long Wall Shearers and to provide manually assisted steering of In-seam Heading Machines

  20. Radiation dose rate measuring device

    International Nuclear Information System (INIS)

    Sorber, R.

    1987-01-01

    A portable device is described for in-field usage for measuring the dose rate of an ambient beta radiation field, comprising: a housing, substantially impervious to beta radiation, defining an ionization chamber and having an opening into the ionization chamber; beta radiation pervious electrically-conductive window means covering the opening and entrapping, within the ionization chamber, a quantity of gaseous molecules adapted to ionize upon impact with beta radiation particles; electrode means disposed within the ionization chamber and having a generally shallow concave surface terminating in a generally annular rim disposed at a substantially close spacing to the window means. It is configured to substantially conform to the window means to define a known beta radiation sensitive volume generally between the window means and the concave surface of the electrode means. The concave surface is effective to substantially fully expose the beta radiation sensitive volume to the radiation field over substantially the full ambient area faced by the window means

  1. Single-strand breaks in oligodeoxyribonucleotides induced by fission neutrons and gamma radiation and measured by gel electrophoresis. Protective effects of aminothiols

    International Nuclear Information System (INIS)

    Swenberg, C.E.; Vaishnav, Y.N.; Li, Bin; Tsao, Hong; Mao, Bing; Geacintov, N.E.

    1997-01-01

    The technique of high-resolution gel electrophoresis using oligodeoxyribonucleotides of known composition as model systems, offers a simple quantitative estimate of DNA damage in aqueous solution induced by ionizing radiation. The fraction of damaged DNA can be quantitatively defined in terms of the increased electrophoretic mobilities of the damaged oligonucleotides, relative to the mobility of the unirradiated and intact oligonucleotides. The usual direct strand breaks can be observed at γ-ray dosages of 200 Gy. However, at a γ-ray dosage of 400 Gy, only a broad background, attributed to heterogeneously and multiply damaged oligonucleotide fragments with overlapping and varying electrophoretic mobilities, can be distinguished. On the other hand, individual bands due to resolvable DNA fragments are evident even at dosages as high as 400 Gy for fission neutrons. When double-stranded oligonucleotides are exposed to γ-ray dosages of 200 Gy, the fraction of damaged DNA approaches 30-40%. This damage can be almost completely suppressed (>99%) if the irradiations are conducted in aqueous solutions in the presence of 0.5-1.0 mM concentrations of the thiols cysteamine or 3-(3-methylaminopropylamino)propanethiol (WR-151326). The rate constant of reaction of OH·radicals with small double stranded oligonucleotides 16 base pairs long, K DNA , is found to be closer to the diffusion-controlled value (>3 x 10 9 M -1 s -1 ) than the magnitudes of K DNA for the higher molecular weight, native DNA reported in the literature. These observations suggest that oligonucleotides represent more simple model systems than native DNA in solutions for studying the mechanisms of radioprotection exerted by thiols of different structures. (author)

  2. Factors influencing in situ gamma-ray measurements

    Science.gov (United States)

    Loonstra, E. H.; van Egmond, F. M.

    2009-04-01

    Introduction In situ passive gamma-ray sensors are very well suitable for mapping physical soil properties. In order to make a qualitative sound soil map, high quality input parameters for calibration are required. This paper will focus on the factors that affect the output of in situ passive gamma-ray sensors, the primary source, soil, not taken into account. Factors The gamma-ray spectrum contains information of naturally occurring nuclides 40K, 238U and 232Th and man-made nuclides like 137Cs, as well as the total count rate. Factors that influence the concentration of these nuclides and the count rate can be classified in 3 categories. These are sensor design, environmental conditions and operational circumstances. Sensor design The main elements of an in situ gamma-ray sensor that influence the outcome and quality of the output are the crystal and the spectrum analysis method. Material and size of the crystal determine the energy resolution. Though widely used, NaI crystals are not the most efficient capturer of gamma radiation. Alternatives are BGO and CsI. BGO has a low peak resolution, which prohibits use in cases where man-made nuclides are subject of interest. The material is expensive and prone to temperature instability. CsI is robust compared to NaI and BGO. The density of CsI is higher than NaI, yielding better efficiency, especially for smaller crystal sizes. More volume results in higher energy efficiency. The reduction of the measured spectral information into concentration of radionuclides is mostly done using the Windows analysis method. In Windows, the activities of the nuclides are found by summing the intensities of the spectrum found in a certain interval surrounding a peak. A major flaw of the Windows method is the limited amount of spectral information that is incorporated into the analysis. Another weakness is the inherent use of ‘stripping factors' to account for contributions of radiation from nuclide A into the peak of nuclide B. This

  3. Mapping of radiation anomalies using UAV mini-airborne gamma-ray spectrometry.

    Science.gov (United States)

    Šálek, Ondřej; Matolín, Milan; Gryc, Lubomír

    2018-02-01

    Localization of size-limited gamma-ray anomalies plays a fundamental role in uranium prospecting and environmental studies. Possibilities of a newly developed mini-airborne gamma-ray spectrometric equipment were tested on a uranium anomaly near the village of Třebsko, Czech Republic. The measurement equipment was based on a scintillation gamma-ray spectrometer specially developed for unmanned aerial vehicles (UAV) mounted on powerful hexacopter. The gamma-ray spectrometer has two 103 cm 3 BGO scintillation detectors of relatively high sensitivity. The tested anomaly, which is 80 m by 40 m in size, was investigated by ground gamma-ray spectrometric measurement in a detail rectangular measurement grid. Average uranium concentration is 25 mg/kg eU attaining 700 mg/kg eU locally. The mini-airborne measurement across the anomaly was carried out on three 100 m long parallel profiles at eight flight altitudes from 5 to 40 m above the ground. The resulting 1 s 1024 channel gamma-ray spectra, recorded in counts per second (cps), were processed to concentration units of K, U and Th, while total count (TC) was reported in cps. Increased gamma ray intensity of the anomaly was indicated by mini-airborne measurement at all profiles and altitudes, including the highest altitude of 40 m, at which the recorded intensity is close to the natural radiation background. The reported instrument is able to record data with comparable quality as standard airborne survey, due to relative sensitive detector, lower flight altitude and relatively low flight speed of 1 m/s. The presented experiment brings new experience with using unmanned semi-autonomous aerial vehicles and the latest mini-airborne radiometric instrument. The experiment has demonstrated the instrument's ability to localize size-limited uranium anomalies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Effect of 60 Co gamma radiation on crystalline proteins

    International Nuclear Information System (INIS)

    Bernardes, D.M.L.

    1991-01-01

    In order to study the effects of 6 0 Co gamma radiation on crystalline proteins an in vitro system was set up. For that, aqueous solutions from bovine crystalline were used irradiated with 0, 5.000, 10.000, 15.000, 20.000 and 25.000 Gy. The treatment led to protein alterations determined by different methods. By turbidimetry the formation of aggregates that increased with the radiation dose was revealed. The same observation was done from viscosity data and from the UV spectrum of the samples. From amino acid analysis and fluorimetry determinations, tryptophan appeared as the most sensitive amino acid. An increase in the free-S H-groups was also observed. After the standardization of the method, the radio modifier capability of glutathione, amino ethyl thiourea, mercapto ethyl alanine and dimethyl sulfoxide was tested. The results showed that in the presence of those substances the radiation effect was diminished. (author)

  5. Effects of beta/gamma radiation on nuclear waste glasses

    Energy Technology Data Exchange (ETDEWEB)

    Weber, W.J. [Pacific Northwest National Lab., Richland, WA (United States)

    1997-07-01

    A key challenge in the disposal of high-level nuclear waste (HLW) in glass waste forms is the development of models of long-term performance based on sound scientific understanding of relevant phenomena. Beta decay of fission products is one source of radiation that can impact the performance of HLW glasses through the interactions of the emitted {beta}-particles and g-rays with the atoms in the glass by ionization processes. Fused silica, alkali silicate glasses, alkali borosilicate glasses, and nuclear waste glasses are all susceptible to radiation effects from ionization. In simple glasses, defects (e.g., non-bridging oxygen and interstitial molecular oxygen) are observed experimentally. In more complex glasses, including nuclear waste glasses, similar defects are expected, and changes in microstructure, such as the formation of bubbles, have been reported. The current state of knowledge regarding the effects of {beta}/{gamma} radiation on the properties and microstructure of nuclear waste glasses are reviewed. (author)

  6. Degradation of electrical insulation of polyethylene under thermal and radiation environment, (4). [Gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Shuhei; Murabayashi, Fumio; Sawa, Goro [Mie Univ., Tsu (Japan); Yamaguchi, Shinji; Ieda, Masayuki

    1982-12-01

    Although the quality assurance guideline for the cables used for the safety and protection systems of nuclear power plants is given by IEEE Standards 323 and 383-1974, in addition, it is important to clarify the aging process under the complex environment of heat and radiation and the equivalence of the accelerated aging test of insulating materials. The authors performed the sequential (H.T-..gamma.. or ..gamma..-HT) and simultaneous (..gamma.., HT) application of respective aging factors of heat and radiation to non-additive low density polyethylene films by changing dose rate as the first stage, to clarify the dose rate dependence of the aging. They mainly investigated the dielectric properties, and forwarded investigation based on the change of carbonyl group by infrared spectrometry and residual free radicals by ESR analysis. In the samples irradiated with ..gamma..-ray only and those irradiated with ..gamma..-ray after thermal treatment for 7 hours at 90 deg C, the absorption coefficient ..cap alpha.. of carbonyl group increased with dose in the range from 3 Mrad to 60 Mrad, and both samples showed approximately the same ..cap alpha.. value. The ..cap alpha.. value of the samples thermally treated after irradiation was larger than that of the samples treated in the reverse order, and the difference between them increased with the increase of dose. The values of dielectric tangent delta at room temperature and 1 kHz for the samples (..gamma..) and (HT-..gamma..) increased with dose, and were almost the same, but those for the samples (..gamma..-HT) and (..gamma.., HT) were larger than the former two.

  7. Automated System of Area Radiation Measurement (ASARM)

    International Nuclear Information System (INIS)

    Hernandez G, J.

    2013-10-01

    The realized activities in nuclear facilities involve the determination of the presence of ionizing radiation fields in the workspaces. The instruments designed to detect and to measure these radiation fields provide useful information (specific type of radiation, intensity, etc.) to take the appropriate radiological protection measures, with the purpose of reducing to the minimum the workers exposition and the people in general. The radiological protection program of Reactor TRIGA Mark III contains the instructions and procedures to implement a periodic radiological monitoring, surveillance, rising of contamination levels, type and number of the instruments required for the radiological monitoring of areas and personal. The ana logical monitoring system model Rms II used to detect and measuring exposition speed and neutron radiation fields in several areas of the installation, provides the information in a logarithmic scale measurer of 4 or 5 decades located in a shelf where the previously mentioned measurement channels are centralized. Also inside the reactor monitoring system are two monitors of radioactive material concentration in the air: The particles continuous monitor and the gaseous effluents monitor which present the referred information of the diverse detectors through ana logical readers. These monitors when operating with an ana logical indication does not present the possibility to generate historical files electronically of each monitor previously mentioned neither to generate visual and audible indications of the alarms. This work presents the Automated System of Area Radiation Measurement which potentiated the functionality of the area monitors for gamma and neutron radiation, as well as of the particles continuous monitor and the gaseous effluents of reactor TRIGA Mark III, when being developed a computer system that captures in real time the information of all the monitors, generating this way an electronic binnacle, a visual and audible alarm

  8. Gamma radiation influence on technological characteristics of wheat flour

    International Nuclear Information System (INIS)

    Teixeira, Christian A.H.M.; Inamura, Patricia Y.; Uehara, Vanessa B.; Mastro, Nelida L.d.

    2012-01-01

    This study aimed at determining the influence of gamma radiation on technological characteristics of wheat (Triticum sativum) flour and physical properties of pan breads made with this flour. The bread formulation included wheat flour, water, milk, salt, sugar, yeast and butter. The α-amylase activity of wheat flour irradiated with 1, 3 and 9 kGy in a Gammacell 220 (AECL), one day, five days and one month after irradiation was evaluated. Deformation force, height and weight of breads prepared with the irradiated flour were also determined. The enzymatic activity increased—reduction of falling number time—as radiation dose increased, their values being 397 s (0 kGy), 388 s (1 kGy), 343 s (3 kGy) and 293 s (9 kGy) respectively, remaining almost constant over the period of one month. Pan breads prepared with irradiated wheat flour showed increased weight. Texture analysis showed that bread made of irradiated flour presented an increase in maximum deformation force. The results indicate that wheat flour ionizing radiation processing may confer increased enzymatic activity on bread making and depending on the irradiation dose, an increase in weight, height and deformation force parameters of pan breads made of it. - Highlights: ► We study the influence of gamma radiation on wheat flour and properties of breads. ► Falling number decreased with radiation remaining almost constant up to one month. ► Ionizing radiation may confer an increase in texture parameters, weight and height on the bread.

  9. Radiomodifying effect of caffeine on mammalian cellular system using gamma radiation and proton beam radiation

    International Nuclear Information System (INIS)

    Samanth, Sneha P.; Yadav, Usha; Shirsath, K.B.; Desai, Utkarsha N.; Chaurasia, Rajesh K.; Bhat, Nagesh N.; Anjaria, K.B.; Sapra, B.K.

    2016-01-01

    Caffeine is a commonly consumed neurostimulant in the world. Reports suggest the radiomodifying effects of caffeine against low Linear Energy Transfer (LET) radiation when administered pre and post irradiation by releasing checkpoint arrest. In the present report, the radioprotective and radiosensitizing ability of caffeine (10μM - 2mM) were studied on Chinese Hamster Ovary (CRO) cell line against low as well as high LET radiation when administered pre, post and continuously during radiation. Effect of caffeine treatment on the genotoxicity induced by gamma and proton beam radiation was assessed by micronucleus assay. Effect of caffeine treatment on clonogenic survival of irradiated cells was also assessed

  10. Definition of priority areas for monitoring of gamma radiation on the surroundings of the CDTN installations

    International Nuclear Information System (INIS)

    Chagas, Claudio Jose; Carvalho Filho, Carlos A.; Peixoto, Claudia Marques; Rodrigues, Paulo C. Horta; Augustin, Cristina Helena R. Rocha

    2013-01-01

    To demonstrate compliance with regulations and legal requirements, the Environmental Monitoring Program of the - Development Center of Nuclear Technology - PMA/CDTN was created in 1985. However, at that time, no data was available to represent the background - the natural level for the pre operational period in terms of Gamma radiation. Thus, the lowest value obtained among the sentinel point sites from the early period of the environmental monitoring was adopted as benchmark. As these measurements were performed by procedures and conditions other than that currently in use, this reference value may not correspond to reality. Therefore, it may not be appropriate to use it as background in assessing the possible environmental impact generated by the activities of the facilities. The goal of this study is to propose an area of geographic distribution for 12 monitoring points, outside the CDTN facilities, so that the real natural Gamma radiation levels can be accurately measured without the interference of the radioactivity levels originating from the institution, enabling the determination of the most representative values of the natural gamma radiation in the area. This survey of the natural radiation determination in the study area, with the use of modern equipment and the application of methodology taking into account historical data, as well the geological, geomorphological and geographical studies of the region, pointed to an average background value of 0.095μSv/h. This result, together with other studies, indicated a maximum range of 25m beyond the CDTN boundaries to distribute the monitoring points. (author)

  11. Gamma radiation and its role in bio prosthetic aortic valves implanted in rat hearts

    International Nuclear Information System (INIS)

    Lamas, Gloria I.; Kairiyama, Eulogia; Navia, Jose

    2000-01-01

    Porcine heart valves glutaraldehyde fixed are implanted in patients with valvular deterioration. Mineralization may be the major factor in the long-term failure of tissue bio prosthesis. Gamma radiation randomly breaks some glutaraldehyde cross-links. As a consequence of irradiation, the polymeric fibers belonging to the valvular tissue are broken too, leading to sites of collagen fiber disorganisation. It is well known that the collagen fibers may act as a passive nucleator of salts where the calcium phosphate salts precipitate. This salt concentration has been described in association with disintegrated sites of protein fiber, which may favour new sites where the calcium salts would be deposit. The irradiation process is a technique used for sterilization of porcine heart valve. The main objective of this work was to study the effect of different doses of gamma radiation on the calcification process of subcutaneously implanted valves in rats. Small pieces from glutaraldehyde fixed valves, irradiated to different doses with a 60 Co sources were implanted subcutaneously in rats. The calcium was measured by X-ray and atomic absorption spectrophotometry. In our experimental conditions and at the radiation doses used in these tests, the calcium measurements on control and irradiated material were not significantly different. We conclude that, at the employed doses, the gamma radiation does not alter the process. (author) [es

  12. Equipment for automatic measurement of gamma activity distribution in a column

    International Nuclear Information System (INIS)

    Kalincak, M.; Machan, V.; Vilcek, S.; Balkovsky, K.

    1978-01-01

    The design of a device for stepwise scanning of gamma activity distributions along chromatographic columns is described. In connection with a single-channel gamma spectrometer and a counting ratemeter with a recorder this device permits the resolution of a number of gamma emitters on the column, the determination of the gamma nuclide content in different chemical forms in the sample by means of column separation methods - Gel Chromatography Columns Scanning Method - and the determination of gamma nuclide distribution along the columns. The device permits the scanning of columns of up to 20 mm in diameter and 700 mm in length and continual scanning over a 450 mm column length with one clamping. With minor adaptations it is possible to scan columns up to 30 mm in diameter. The length of the scanned sections is 5 or 10 mm, the scanning time setting is arbitrary and variable activity levels and radiation energies may be measured. (author)

  13. Effect of gamma radiation on chitin-nanosilver membranes

    International Nuclear Information System (INIS)

    Singh, Rita; Singh, Durgeshwer

    2014-01-01

    Antimicrobial wound dressings are indispensable for the effective healing of skin wounds such as burns and ulcers. Various synthetic and natural polymers with good biocompatibility have been used to develop wound dressings. Chitin possesses excellent properties that are advantageous for wound dressing namely biocompatibility, biodegradability and haemostatic activity. Chitin-nanosilver membranes were developed for use as an antimicrobial dressing for wound care. For clinical applications, the wound dressing should be assuredly free of microbial contamination. Gamma irradiation has well appreciated technological advantages and is the most suitable method for the sterilization of biomedical materials. The present study was carried out to evaluate the effect of gamma radiation on the chemical and functional characteristics of the chitin-nanosilver membranes

  14. Effect of gamma radiation on the poly(vinyl alcohol)

    International Nuclear Information System (INIS)

    Terence, M.C.; Guedes, S.M.L.

    2000-01-01

    The poly(vinyl alcohol) (PVAL) is a polymer used as bio material. The PVAL was used as ocular insert and may be used as a drug delivery system (DDS) for pair PVAL/gancyclovir, where the last one is used for treatment of people with retinitis caused by cytomegalovirus. These inserts are crosslinked systems. The crosslink was induced by gamma radiation applied in polymer. The samples of PVAL was irradiated by gamma rays with doses in the range 0 to 100 kGy. On irradiated PVAL samples was observed a low yellowness, attributed to the formation of polymeric radicals that are stable in the structure of the polymer, from radiolysis of PVAL. (author)

  15. Sources of gamma radiation in a reactor core

    Energy Technology Data Exchange (ETDEWEB)

    Roos, Matts

    1959-05-15

    In a thermal reactor the gamma ray sources of importance for shielding calculations and related aspects are 1) fission, 2) decay of fission products, 3) capture processes in fuel, poison and other materials, 4) inelastic scattering in the fuel and 5) decay of capture products. The energy release and the gamma ray spectra of these sources have been compiled or estimated from the latest information available, and the results are presented in a general way to permit application to any thermal reactor, fueled with a mixture of {sup 235}U and {sup 238}U. As an example the total spectrum and the spectrum of radiation escaping from a fuel rod in the Swedish R3-reactor are presented.

  16. Perception of gamma radiation by adults of Sitophilus zeamais mots

    International Nuclear Information System (INIS)

    Wiendl, F.M.; Walder, J.M.M.

    1975-05-01

    Perception of gamma radiation by living organisms has been evidenced only a few times. The occurence of such perception with maize weevil, Sitophilus zeamais Motschulsky is presented. Tubes containing maize weevil were placed in a radial position to a gamma source. Counting of the insects inside the tubes at different distances from the source was made immediately after irradiation. It was noticed that the insects submitted to irradiation had been driven away from the source as compared with those not submitted (control). A possible relationship exists between this effect and the Cerenkov effect which affects directly the visual organs of the insect. This is probably due to the fact that the insects have a large quantity of water in the occular cells

  17. Improvement of PVC floor tiles by gamma radiation

    International Nuclear Information System (INIS)

    Plessis, T.A. du; Badenhorst, F.

    1988-01-01

    Gamma radiation presents a unique method of transforming highly plasticized PVC floor tiles, manufactured at high speed through injection moulding, into a high quality floor covering at a cost at least 30% less than similarly rated rubber tiles. A specially formulated PVC compound was developed in collaboration with a leading manufacturer of floor tiles. These tiles are gamma crosslinked in its shipping cartons to form a dimensionally stable product which is highly fire resistant and inert to most chemicals and solvents. These crosslinked tiles are more flexible than the highly filled conventional PVC floor tiles, scratch resistant and have a longer lifespan and increased colour fastness. These tiles are also less expensive to install than conventional rubber tiles. (author)

  18. Gamma radiation for the decontamination of soil containing dioxin

    International Nuclear Information System (INIS)

    Chhor, M.P.; Wethington, J.A. Jr.

    1986-01-01

    Dioxin-2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) contamination poses an environmental danger. Different methods for the cleanup of contaminated sites have been proposed. The G value for dioxin dispersed in soil wetted with ethanol is much greater than G values for typical aromatic hydrocarbons. Doses > 6.24 x 10 23 eV/kg lead to decreasing rates of destruction of TCDD, and doses > 24.97 x 10 23 eV/kg are not very effective. Gamma irradiation of contaminated soil apparently will not result in large (powers of 10) decontamination factor. The concept of using gamma radiation for the degradation of TCDD in contaminated soil is about as good or as bad as other methods being tested

  19. Effects of gamma radiation on codling moth, Cydia pomonella (L.), eggs

    International Nuclear Information System (INIS)

    Mansour, M.; Mohamad, F

    2005-01-01

    The radiosensitivity of codling moth, Cydia pomonella (L.), eggs in different stages of development was studied. Eggs ranging in age from 1-24 to 97-120 h were exposed, at 24 h intervals, to gamma radiation doses ranging from 10 to 350 Gy. The effects of gamma radiation on egg hatch, pupation and adult emergence was examined. Results showed that the radiosensitivity of codling moth eggs decreased with increasing age. Egg hatch in 1-24 h old eggs was significantly affected at 20 Gy dose and at 60 Gy dose, egg hatch decreased to about 1%. At the age of 25-48 h, however, egg hatch at 60 Gy dose was about 10%, and egg sensitivity to gamma irradiation decreased significantly in the 49-72 h age group; 60 Gy dose had no significant effect on egg hatch. Eggs irradiated few hours before hatch (at the blackhead stage), were the most resistant ones; 100 Gy had no significant effect on egg hatch and at 350 Gy dose over 56% of the eggs hatched. When adult emergence was used as a criterion for measuring effectiveness, however, the effect of gamma radiation was very sever. A dose of 60 Gy completely prevented adult emergence and at 100 Gy dose all resulted larvae died before pupation. (Author)

  20. Effects of gamma radiation on codling moth, Cydia pomonella (L.), eggs

    International Nuclear Information System (INIS)

    Mansour, M.; Mohamad, F.

    2004-01-01

    The radiosensitivity of codling moth, Cydia pomonella (L.), eggs in different stages of development was studied. Eggs ranging in age from 1-24 to 97-120 h were exposed, at 24 h intervals, to gamma radiation doses ranging from 10 to 350 Gy. The effects of gamma radiation on egg hatch, pupation and adult emergence was examined. Results showed that the radiosensitivity of codling moth eggs decreased with increasing age. Egg hatch in 1-24 h old eggs was significantly affected at 20 Gy dose and at 60 Gy dose, egg hatch decreased to about 1%. At the age of 25-48 h, however, egg hatch at 60 Gy dose was about 10%, and egg sensitivity to gamma irradiation decreased significantly in the 49-72 h age group; 60 Gy dose had no significant effect on egg hatch. Eggs irradiated few hours before hatch (at the blackhead stage), were the most resistant ones; 100 Gy had no significant effect on egg hatch and at 350 Gy dose over 56% of the eggs hatched. When adult emergence was used as a criterion for measuring effectiveness, however, the effect of gamma radiation was very sever. A dose of 60 Gy completely prevented adult emergence and at 100 Gy dose all resulted larvae died before pupation